Sample records for floor cleaning methods

  1. The cleaning of ward floors and the bacteriological study of floor-cleaning machines

    PubMed Central

    Bate, J. G.

    1961-01-01

    Current trends in ward flooring materials and cleaning methods are considered from the point of view of the hospital bacteriologist. Methods employed in an investigation into the bacteriological safety of a number of floor-cleaning machines are described, and some considerations governing the choice of vacuum cleaners for ward use are discussed. Images PMID:13687726

  2. Floor cleaning: effect on bacteria and organic materials in hospital rooms.

    PubMed

    Andersen, B M; Rasch, M; Kvist, J; Tollefsen, T; Lukkassen, R; Sandvik, L; Welo, A

    2009-01-01

    Routine surface cleaning is recommended to control the spread of pathogens in hospital environments. In Norway, ordinary cleaning of patient rooms is traditionally performed with soap and water. In this study, four floor-mopping methods--dry, spray, moist and wet mopping--were compared by two systems using adenosine triphosphate (ATP) bioluminescence (Hygiena and Biotrace). These systems assess residual organic soil on surfaces. The floor-mopping methods were also assessed by microbiological samples from the floor and air, before and after cleaning. All methods reduced organic material on the floors but wet and moist mopping seemed to be the most effective (P < 0.001, P < 0.011, respectively, ATP Hygiena). The two ATP methods were easy to use, although each had their own reading scales. Cleaning reduced organic material to 5-36% of the level present before cleaning, depending upon mopping method. All four mopping methods reduced bacteria on the floor from about 60-100 to 30-60 colony-forming units (cfu)/20cm2 floor. Wet, moist and dry mopping seemed to be more effective in reducing bacteria on the floor, than the spray mopping (P=0.007, P=0.002 and P=0.011, respectively). The burden of bacteria in air increased for all methods just after mopping. The overall best cleaning methods seemed to be moist and wet mopping.

  3. Improving the cleaning procedure to make kitchen floors less slippery.

    PubMed

    Quirion, F; Poirier, P; Lehane, P

    2008-12-01

    This investigation shows that, in most cases, the floor cleaning procedure of typical restaurants could be improved, resulting in a better cleaning efficiency and a better floor friction. This simple approach could help reduce slips and falls in the workplace. Food safety officers visited ten European style restaurants in the London Borough of Bromley (UK) to identify their floor cleaning procedure in terms of the cleaning method, the concentration and type of floor cleaner and the temperature of the wash water. For all 10 restaurants visited, the cleaning method was damp mopping. Degreasers were used in three sites while neutral floor cleaners were used in seven sites. Typically, the degreasers were over diluted and the neutrals were overdosed. The wash water temperature ranged from 10 to 72 degrees C. The on-site cleaning procedures were repeated in the laboratory for the removal of olive oil from new and sealed quarry tiles, fouled and worn quarry tiles and new porcelain tiles. It is found that in 24 out of 30 cases, cleaning efficiency can be improved by simple changes in the floor cleaning procedure and that these changes result in a significant improvement of the floor friction. The nature of the improved floor cleaning procedure depends on the flooring type. New and properly sealed flooring tiles can be cleaned using damp mopping with a degreaser diluted as recommended by the manufacturer in warm or hot water (24 to 50 degrees C). But as the tiles become worn and fouled, a more aggressive floor cleaning is required such as two-step mopping with a degreaser diluted as recommended by the manufacturer in warm water (24 degrees C).

  4. Operational Testing of Floor Cleaning Cloths for Household ...

    EPA Pesticide Factsheets

    Report The objective of this study was to evaluate the Swiffer® Sweeper® floor mop system (SSFMS) as a low-tech method to clean indoor residential floors contaminated with B. anthracis spores (the causative agent of anthrax).

  5. Removal of lead contaminated dusts from hard surfaces.

    PubMed

    Lewis, Roger D; Condoor, Sridhar; Batek, Joe; Ong, Kee Hean; Backer, Denis; Sterling, David; Siria, Jeff; Chen, John J; Ashley, Peter

    2006-01-15

    Government guidelines have widely recommended trisodium phosphate (TSP) or "lead-specific" cleaning detergents for removal of lead-contaminated dust (LCD) from hard surfaces, such as floors and window areas. The purpose of this study was to determine if low-phosphate, non-lead-specific cleaners could be used to efficiently remove LCD from 3 types of surfaces (vinyl flooring, wood, and wallpaper). Laboratory methods were developed and validated for simulating the doping, embedding, and sponge cleaning of the 3 surface types with 4 categories of cleaners: lead-specific detergents, nonionic cleaners, anionic cleaners, and trisodium phosphate (TSP). Vinyl flooring and wood were worn using artificial means. Materials were ashed, followed by ultrasound extraction, and anodic stripping voltammetry (ASV). One-way analysis of variance approach was used to evaluate the surface and detergent effects. Surface type was found to be a significant factor in removal of lead (p < 0.001). Vinyl flooring cleaned better than wallpaper by over 14% and wood cleaned better than wallpaper by 13%. There was no difference between the cleaning action of vinyl flooring and wood. No evidence was found to support the use of TSP or lead-specific detergents over all-purpose cleaning detergents for removal of lead-contaminated dusts. No-phosphate, non-lead-specific detergents are effective in sponge cleaning of lead-contaminated hard surfaces and childhood lead prevention programs should consider recommending all-purpose household detergents for removal of lead-contaminated dust after appropriate vacuuming.

  6. Floors: Care and Maintenance.

    ERIC Educational Resources Information Center

    Post Office Dept., Washington, DC.

    Guidelines, methods and policies regarding the care and maintenance of post office building floors are overviewed in this handbook. Procedures outlined are concerned with maintaining a required level of appearance without wasting manpower. Flooring types and characteristics and the particular cleaning requirements of each type are given along with…

  7. Evaluation of common cleaning and disinfection programmes in battery cage and on-floor layer houses in France.

    PubMed

    Huneau-Salaün, A; Michel, V; Balaine, L; Petetin, I; Eono, F; Ecobichon, F; Bouquin, S Le

    2010-04-01

    1. The aim in this study was to evaluate cleaning and disinfection programmes in battery cage and on-floor layer houses in France. 2. Cleaning and disinfection efficiency was assessed by a visual evaluation of cleaning and a bacteriological monitoring of surface contamination from counts of thermotolerant streptococci on contact agar plates. 3. In battery cage houses, dropping belts, manure conveyors, and house floors remained highly contaminated due to poor cleaning in half of the buildings examined. 4. In on-floor houses, a high standard of cleaning was achieved but errors in the planning of cleaning and disinfection operations sometimes led to a high residual contamination of nest boxes and egg sorting tables.

  8. Evaluation of a bioluminescence method, contact angle measurements and topography for testing the cleanability of plastic surfaces under laboratory conditions

    NASA Astrophysics Data System (ADS)

    Redsven, I.; Kymäläinen, H.-R.; Pesonen-Leinonen, E.; Kuisma, R.; Ojala-Paloposki, T.; Hautala, M.; Sjöberg, A.-M.

    2007-04-01

    Detection of adenosine triphosphate (ATP) by bioluminescence is used, for instance, in the food industry and in hospitals to assess the hygiene status of surfaces. The aim of this laboratory study was to investigate the feasibility of the ATP method for estimating the cleanability of resilient floor coverings from biological soil. The surfaces were worn using a Soiling and Wearing Drum Tester, and soiled and cleaned with an Erichsen Washability and Scrubbing Resistance Tester. In the laboratory test carried out with the bioluminescence method, most of the new and worn floor coverings that were biologically soiled were cleaned efficiently. According to this study, the semiquantitative ATP screening method can be used for hygiene monitoring of flooring materials. No correlation was found between cleanability and contact angles or surface topography measured using a profilometer. However, by revealing local irregularities and damage on surfaces, scanning electron micrographs appeared useful in explaining differences in cleanability.

  9. Programmed for Results.

    ERIC Educational Resources Information Center

    Larock, Barb

    2000-01-01

    Explores how establishing a floor-care maintenance program can reduce costs, improve safety, and enhance a school's appearance. Topics include the use of entrance matting to reduce dirt and water tracking, cleaning with floor pads and brushes, and proper chemical cleaning management of hard wood floors. (GR)

  10. 9 CFR 354.241 - Cleaning of rooms and compartments.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... skinning room shall be kept clean and free from offensive odors at all times. (g) The walls, floors, and all equipment and utensils used in the killing and skinning room shall be thoroughly washed and cleaned after each day's operation. (h) The floor in the killing and skinning rooms shall be cleaned...

  11. 9 CFR 354.241 - Cleaning of rooms and compartments.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... skinning room shall be kept clean and free from offensive odors at all times. (g) The walls, floors, and all equipment and utensils used in the killing and skinning room shall be thoroughly washed and cleaned after each day's operation. (h) The floor in the killing and skinning rooms shall be cleaned...

  12. 9 CFR 354.243 - Operations and procedures.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ...) The floors in the eviscerating room shall be kept clean and reasonably dry during eviscerating... accord with clean and sanitary methods. (a) There shall be no handling or storing of materials which create an objectionable condition in rooms, compartments, or other places in the plant where any product...

  13. 9 CFR 354.243 - Operations and procedures.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...) The floors in the eviscerating room shall be kept clean and reasonably dry during eviscerating... accord with clean and sanitary methods. (a) There shall be no handling or storing of materials which create an objectionable condition in rooms, compartments, or other places in the plant where any product...

  14. 9 CFR 354.243 - Operations and procedures.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...) The floors in the eviscerating room shall be kept clean and reasonably dry during eviscerating... accord with clean and sanitary methods. (a) There shall be no handling or storing of materials which create an objectionable condition in rooms, compartments, or other places in the plant where any product...

  15. Design and Development of Mopping Robot-'HotBot'

    NASA Astrophysics Data System (ADS)

    Khan, M. R.; Huq, N. M. L.; Billah, M. M.; Ahmmad, S. M.

    2013-12-01

    To have a healthy, comfortable, and fresh civilized life we need to do some unhealthy households. Cleaning the dirty floor with a mop is one of the most disgusting and scary house hold jobs. Mopping robots are a solution of such problem. However, these robots are still on the way to be smart enough. Many points limit their efficiency, i.e. cleaning sticky dirt, having dry floor after cleaning, monitoring, cost etc. 'HotBot' is a mopping robot that can clean dirty floor with nice efficiency leaving no sticky dirt. Hot water can be used for heavy stains or normal water for usual situation and economy. It needs neither to be monitored during mopping nor to wipe the floor after it. 'HotBot' has sensors to detect obstacles and a control mechanism to avoid those. Moreover, it cleans sequentially and equipped with several accident-protection-systems. Moreover, it is also cost effective compared to the robots available so far.

  16. Does Flooring Substrate Impact Kennel and Dog Cleanliness in Commercial Breeding Facilities?

    PubMed Central

    Stella, Judith; Hurt, Moriah; Bauer, Amy; Croney, Candace

    2018-01-01

    Simple Summary It is important to understand how the flooring substrate used in dog housing impacts dog health and well-being. Aspects to consider include paw, elbow, and hock health, the cleanliness of the dog, and the ability of the floors to be cleaned easily and thoroughly. This pilot study assessed the health and cleanliness of 118 dogs housed on three different types of flooring commonly found in commercial breeding kennels. No serious paw, elbow, or hock problems were identified. Thirty-one percent or fewer kennels at each facility were found to have fecal contamination after routine cleaning and the majority of dogs were clean. These findings indicate that a well-managed kennel can maintain clean, healthy dogs on different types of flooring substrates. Abstract Evaluation of kennel flooring surfaces is needed to understand their impacts on dog health and well-being. This pilot study aimed to characterize aspects of physical health, kennel cleanliness, and dog body cleanliness on flooring types common in US breeding kennels. Subjects were 118 adult dogs housed on diamond-coated expanded metal (DCEM), polypropylene (POLY), or concrete (CON) flooring at five commercial breeding facilities in Indiana, U.S. Body condition, paw, elbow, and hock health scores were recorded. Each indoor kennel and dog was visually assessed for cleanliness. Kennels were swabbed immediately after cleaning with electrostatic dry cloths and cultured for Escherichia coli. Descriptive statistics were used for analysis. Mean body condition score (BCS), kennel and dog cleanliness scores were all near ideal (3, 1.15, and 1.04, respectively). Thirty-one percent or fewer kennels at each facility were culture-positive for E. coli after cleaning. No serious paw, elbow, or hock problems were identified. Overall, the findings indicate that with appropriate management and regular access to additional surfaces, dog foot health, cleanliness, and kennel cleanliness can be maintained on the flooring types investigated. PMID:29690514

  17. Electronic system for floor surface type detection in robotics applications

    NASA Astrophysics Data System (ADS)

    Tarapata, Grzegorz; Paczesny, Daniel; Tarasiuk, Łukasz

    2016-11-01

    The paper reports a recognizing method base on ultrasonic transducers utilized for the surface types detection. Ultra-sonic signal is transmitted toward the examined substrate, then reflected and scattered signal goes back to another ultra-sonic receiver. Thee measuring signal is generated by a piezo-electric transducer located at specified distance from the tested substrate. The detector is a second piezo-electric transducer located next to the transmitter. Depending on thee type of substrate which is exposed by an ultrasonic wave, the signal is partially absorbed inn the material, diffused and reflected towards the receiver. To measure the level of received signal, the dedicated electronic circuit was design and implemented in the presented systems. Such system was designed too recognize two types of floor surface: solid (like concrete, ceramic stiles, wood) and soft (carpets, floor coverings). The method will be applied in electronic detection system dedicated to autonomous cleaning robots due to selection of appropriate cleaning method. This work presents the concept of ultrasonic signals utilization, the design of both the measurement system and the measuring stand and as well number of wide tests results which validates correctness of applied ultrasonic method.

  18. 33. FIFTH FLOOR BLDG. 27, "CLEAN ROOM" LOOKING NORTH. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    33. FIFTH FLOOR BLDG. 27, "CLEAN ROOM" LOOKING NORTH. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  19. 87. SIXTH FLOOR BLDG. 19 "CLEAN ROOM" LOOKING WEST. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    87. SIXTH FLOOR BLDG. 19 "CLEAN ROOM" LOOKING WEST. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  20. 36. FIFTH FLOOR BLDG. 27, "CLEAN ROOM" AIR FILTERS LOOKING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    36. FIFTH FLOOR BLDG. 27, "CLEAN ROOM" AIR FILTERS LOOKING SOUTH. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  1. 35. FIFTH FLOOR BLDG. 27, "CLEAN ROOM" DINING AREA LOOKING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    35. FIFTH FLOOR BLDG. 27, "CLEAN ROOM" DINING AREA LOOKING WEST. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  2. 34. FIFTH FLOOR BLDG. 27, "CLEAN ROOM" ENTRANCE CORRIDOR LOOKING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    34. FIFTH FLOOR BLDG. 27, "CLEAN ROOM" ENTRANCE CORRIDOR LOOKING SOUTH. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  3. 9 CFR 3.84 - Cleaning, sanitization, housekeeping, and pest control.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... from becoming soiled, and to reduce disease hazards, insects, pests, and odors. Dirt floors, floors..., such as in a mechanical cage washer; (iii) Washing all soiled surfaces with appropriate detergent... same purpose, with a thorough cleaning of the surfaces to remove organic material, so as to remove all...

  4. 9 CFR 3.84 - Cleaning, sanitization, housekeeping, and pest control.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... from becoming soiled, and to reduce disease hazards, insects, pests, and odors. Dirt floors, floors..., such as in a mechanical cage washer; (iii) Washing all soiled surfaces with appropriate detergent... same purpose, with a thorough cleaning of the surfaces to remove organic material, so as to remove all...

  5. 9 CFR 3.84 - Cleaning, sanitization, housekeeping, and pest control.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... from becoming soiled, and to reduce disease hazards, insects, pests, and odors. Dirt floors, floors..., such as in a mechanical cage washer; (iii) Washing all soiled surfaces with appropriate detergent... same purpose, with a thorough cleaning of the surfaces to remove organic material, so as to remove all...

  6. 9 CFR 3.84 - Cleaning, sanitization, housekeeping, and pest control.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... from becoming soiled, and to reduce disease hazards, insects, pests, and odors. Dirt floors, floors..., such as in a mechanical cage washer; (iii) Washing all soiled surfaces with appropriate detergent... same purpose, with a thorough cleaning of the surfaces to remove organic material, so as to remove all...

  7. 9 CFR 3.84 - Cleaning, sanitization, housekeeping, and pest control.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... from becoming soiled, and to reduce disease hazards, insects, pests, and odors. Dirt floors, floors..., such as in a mechanical cage washer; (iii) Washing all soiled surfaces with appropriate detergent... same purpose, with a thorough cleaning of the surfaces to remove organic material, so as to remove all...

  8. The Secrets of Effective Floor Care.

    ERIC Educational Resources Information Center

    Michels, Ed

    2002-01-01

    Discusses the importance of staff training and a maintenance program to the care of hard floors. Describes four key features to look for in a computer-based training program and types of floor pads and matting used to keep flooring clean. (EV)

  9. Mixed-Up Floors.

    ERIC Educational Resources Information Center

    Shaw, Richard

    2001-01-01

    Examines the maintenance management problems inherent in cleaning multiple flooring materials revealing the need for school officials to keep it simple when choosing flooring types. Also highlighted is a carpet recycling program used by Wright State University (Ohio). (GR)

  10. Environmental and body contamination from cleaning vomitus in a health care setting: A simulation study.

    PubMed

    Phan, Linh; Su, Yu-Min; Weber, Rachel; Fritzen-Pedicini, Charissa; Edomwande, Osayuwamen; Jones, Rachael M

    2018-04-01

    Environmental service workers may be exposed to pathogens during the cleaning of pathogen-containing bodily fluids. Participants with experience cleaning hospital environments were asked to clean simulated, fluorescein-containing vomitus using normal practices in a simulated patient room. Fluorescein was visualized in the environment and on participants under black lights. Fluorescein was quantitatively measured on the floor, in the air, and on gloves and shoe covers. In all 21 trials involving 7 participants, fluorescein was found on the floor after cleaning and on participants' gloves. Lower levels of floor contamination were associated with the use of towels to remove bulk fluid (ρ = -0.56, P = .01). Glove contamination was not associated with the number or frequency of contacts with environmental surfaces, suggesting contamination occurs with specific events, such as picking up contaminated towels. Fluorescein contamination on shoe covers was measured in 19 trials. Fluorescein was not observed on participants' facial personal protective equipment, if worn, or faces. Contamination on other body parts, primarily the legs, was observed in 8 trials. Fluorescein was infrequently quantified in the air. Using towels to remove bulk fluid prior to mopping is part of the recommended cleaning protocol and should be used to minimize residual contamination. Contamination on shoes and the floor may serve as reservoirs for pathogens. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  11. Comparison of home lead dust reduction techniques on hard surfaces: the New Jersey assessment of cleaning techniques trial.

    PubMed Central

    Rich, David Q; Rhoads, George G; Yiin, Lih-Ming; Zhang, Junfeng; Bai, Zhipeng; Adgate, John L; Ashley, Peter J; Lioy, Paul J

    2002-01-01

    High efficiency particulate air filter (HEPA) vacuums, which collect particles > 0.3 micro m, and trisodium phosphate (TSP), a detergent claimed to selectively remove lead, have been included in the HUD Guidelines for the Evaluation and Control of Lead Based Paint Hazards in Housing without systematic validation of their effectiveness. At the time the study was initiated, both HEPA vacuums and TSP were relatively expensive, they were not readily found in urban retail centers, and there were environmental concerns about the use and disposal of high-phosphate detergents. A randomized, controlled trial was conducted in urban high-risk homes in northern New Jersey to determine whether a more readily available and less expensive low-phosphate, non-TSP detergent and non-HEPA vacuum could perform as well as TSP and a HEPA vacuum in a cleaning protocol. Homes were randomized to one of three cleaning methods: TSP/HEPA vacuum, TSP/non-HEPA vacuum, or non-TSP/non-HEPA vacuum. Change in log-transformed lead loading was used in mixed models to compare the efficacy of the three cleaning techniques separately for uncarpeted floors, window sills, and window troughs. After we adjusted for baseline lead loading, the non-HEPA vacuum produced larger reductions on hard floors [19%; 95% confidence interval (CI), 3-38%], but the HEPA vacuum produced larger reductions on window sills (22%; 95% CI, 11-32%) and larger reductions on window troughs (16%; 95% CI, -4 to 33%). The non-TSP produced larger reductions on window troughs (21%; 95% CI, -2 to 50%), but TSP produced larger reductions on hard floors (5%; 95% CI, -12 to 19%) and window sills (8%; 95% CI, -5 to 20%). TSP/HEPA produced larger reductions on window sills (28%; 95% CI, 18-37%) and larger reductions on window troughs (2%; 95% CI, -24 to 23%), whereas the non-TSP/non-HEPA method produced larger reductions on hard floors (13%; 95% CI, -5 to 34%). Because neither vacuum nor detergent produced consistent results across surface types, the use of low-phosphate detergents and non-HEPA vacuums in a temporary control measure is supported. PMID:12204823

  12. Comparison of home lead dust reduction techniques on hard surfaces: the New Jersey assessment of cleaning techniques trial.

    PubMed

    Rich, David Q; Rhoads, George G; Yiin, Lih-Ming; Zhang, Junfeng; Bai, Zhipeng; Adgate, John L; Ashley, Peter J; Lioy, Paul J

    2002-09-01

    High efficiency particulate air filter (HEPA) vacuums, which collect particles > 0.3 micro m, and trisodium phosphate (TSP), a detergent claimed to selectively remove lead, have been included in the HUD Guidelines for the Evaluation and Control of Lead Based Paint Hazards in Housing without systematic validation of their effectiveness. At the time the study was initiated, both HEPA vacuums and TSP were relatively expensive, they were not readily found in urban retail centers, and there were environmental concerns about the use and disposal of high-phosphate detergents. A randomized, controlled trial was conducted in urban high-risk homes in northern New Jersey to determine whether a more readily available and less expensive low-phosphate, non-TSP detergent and non-HEPA vacuum could perform as well as TSP and a HEPA vacuum in a cleaning protocol. Homes were randomized to one of three cleaning methods: TSP/HEPA vacuum, TSP/non-HEPA vacuum, or non-TSP/non-HEPA vacuum. Change in log-transformed lead loading was used in mixed models to compare the efficacy of the three cleaning techniques separately for uncarpeted floors, window sills, and window troughs. After we adjusted for baseline lead loading, the non-HEPA vacuum produced larger reductions on hard floors [19%; 95% confidence interval (CI), 3-38%], but the HEPA vacuum produced larger reductions on window sills (22%; 95% CI, 11-32%) and larger reductions on window troughs (16%; 95% CI, -4 to 33%). The non-TSP produced larger reductions on window troughs (21%; 95% CI, -2 to 50%), but TSP produced larger reductions on hard floors (5%; 95% CI, -12 to 19%) and window sills (8%; 95% CI, -5 to 20%). TSP/HEPA produced larger reductions on window sills (28%; 95% CI, 18-37%) and larger reductions on window troughs (2%; 95% CI, -24 to 23%), whereas the non-TSP/non-HEPA method produced larger reductions on hard floors (13%; 95% CI, -5 to 34%). Because neither vacuum nor detergent produced consistent results across surface types, the use of low-phosphate detergents and non-HEPA vacuums in a temporary control measure is supported.

  13. Clean then Assemble Versus Assemble then Clean: Several Comparisons

    NASA Technical Reports Server (NTRS)

    Welker, Roger W.

    2004-01-01

    Cleanliness of manufactured parts and assemblies is a significant issue in many industries including disk drives, semiconductors, aerospace, and medical devices. Clean manufacturing requires cleanroom floor space and cleaning technology that are both expensive to own and expensive to operate. Strategies to reduce these costs are an important consideration. One strategy shown to be effective at reducing costs is to assemble parts into subassemblies and then clean the subassembly, rather than clean the individual parts first and then assemble them. One advantage is that assembly outside of the cleanroom reduces the amount of cleanroom floor space and its associated operating cost premium. A second advantage is that this strategy reduces the number of individual parts that must be cleaned prior to assembly, reducing the number of cleaning baskets, handling and, possibly, reducing the number of cleaners. The assemble then clean strategy also results in a part that is significantly cleaner because contamination generated during the assembly steps are more effectively removed that normally can be achieved by hand wiping after assembly in the cleanroom.

  14. Ozone-initiated terpene reaction products in five European offices: replacement of a floor cleaning agent.

    PubMed

    Nørgaard, A W; Kofoed-Sørensen, V; Mandin, C; Ventura, G; Mabilia, R; Perreca, E; Cattaneo, A; Spinazzè, A; Mihucz, V G; Szigeti, T; de Kluizenaar, Y; Cornelissen, H J M; Trantallidi, M; Carrer, P; Sakellaris, I; Bartzis, J; Wolkoff, P

    2014-11-18

    Cleaning agents often emit terpenes that react rapidly with ozone. These ozone-initiated reactions, which occur in the gas-phase and on surfaces, produce a host of gaseous and particulate oxygenated compounds with possible adverse health effects in the eyes and airways. Within the European Union (EU) project OFFICAIR, common ozone-initiated reaction products were measured before and after the replacement of the regular floor cleaning agent with a preselected low emitting floor cleaning agent in four offices located in four EU countries. One reference office in a fifth country did not use any floor cleaning agent. Limonene, α-pinene, 3-carene, dihydromyrcenol, geraniol, linalool, and α-terpineol were targeted for measurement together with the common terpene oxidation products formaldehyde, 4-acetyl-1-methylcyclohexene (4-AMCH), 3-isopropenyl-6-oxo-heptanal (IPOH), 6-methyl-5-heptene-2-one, (6-MHO), 4-oxopentanal (4-OPA), and dihydrocarvone (DHC). Two-hour air samples on Tenax TA and DNPH cartridges were taken in the morning, noon, and in the afternoon and analyzed by thermal desorption combined with gas chromatography/mass spectrometry and HPLC/UV analysis, respectively. Ozone was measured in all sites. All the regular cleaning agents emitted terpenes, mainly limonene and linalool. After the replacement of the cleaning agent, substantially lower concentrations of limonene and formaldehyde were observed. Some of the oxidation product concentrations, in particular that of 4-OPA, were also reduced in line with limonene. Maximum 2 h averaged concentrations of formaldehyde, 4-AMCH, 6-MHO, and IPOH would not give rise to acute eye irritation-related symptoms in office workers; similarly, 6-AMCH, DHC and 4-OPA would not result in airflow limitation to the airways.

  15. 9 CFR 354.241 - Cleaning of rooms and compartments.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... compartments. Rooms, compartments, or other parts of the official plant shall be kept clean and in sanitary... light fixtures in the official plant shall be kept clean. (c) All docks and rooms shall be kept clean... rooms should be kept clean at all times. (e) Floors in live rabbit holding rooms shall be cleaned with...

  16. 9 CFR 354.241 - Cleaning of rooms and compartments.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... compartments. Rooms, compartments, or other parts of the official plant shall be kept clean and in sanitary... light fixtures in the official plant shall be kept clean. (c) All docks and rooms shall be kept clean... rooms should be kept clean at all times. (e) Floors in live rabbit holding rooms shall be cleaned with...

  17. Seeing Red Over Those Black Marks on Your Floors?

    ERIC Educational Resources Information Center

    Rittner-Heir, Robbin

    1999-01-01

    Describes one custodian's cost-effective approach for resolving black scuff marks on flooring and staving off their return. An eight-step cleaning program is detailed. Cautions that the largest obstacle to proper handling of floor problems lies in the lack of a proper maintenance schedule. (GR)

  18. 9 CFR 145.6 - Specific provisions for participating hatcheries.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ..., ceilings, floors, doors, fans, vents, and ducts should be cleaned and disinfected after each hatch. Hatcher rooms should be cleaned and disinfected after each hatch and should not be used for storage. Plenums should be cleaned after each hatch. Cleaning and disinfection procedures should be as outlined in § 147...

  19. 9 CFR 145.6 - Specific provisions for participating hatcheries.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ..., ceilings, floors, doors, fans, vents, and ducts should be cleaned and disinfected after each hatch. Hatcher rooms should be cleaned and disinfected after each hatch and should not be used for storage. Plenums should be cleaned after each hatch. Cleaning and disinfection procedures should be as outlined in § 147...

  20. 9 CFR 145.6 - Specific provisions for participating hatcheries.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ..., ceilings, floors, doors, fans, vents, and ducts should be cleaned and disinfected after each hatch. Hatcher rooms should be cleaned and disinfected after each hatch and should not be used for storage. Plenums should be cleaned after each hatch. Cleaning and disinfection procedures should be as outlined in § 147...

  1. A prospective study of floor surface, shoes, floor cleaning and slipping in US limited-service restaurant workers.

    PubMed

    Verma, Santosh K; Chang, Wen Ruey; Courtney, Theodore K; Lombardi, David A; Huang, Yueng-Hsiang; Brennan, Melanye J; Mittleman, Murray A; Ware, James H; Perry, Melissa J

    2011-04-01

    Slips and falls are a leading cause of injury at work. Few studies, however, have systematically examined risk factors of slipping outside the laboratory environment. This study examined the association between floor surface characteristics, slip-resistant shoes, floor cleaning frequency and the risk of slipping in limited-service restaurant workers. 475 workers from 36 limited-service restaurants from three major chains in six states in the USA were recruited to participate in a prospective cohort study of workplace slipping. Kitchen floor surface roughness and coefficient of friction (COF) were measured in eight working areas and then averaged within each restaurant. The use of slip-resistant shoes was determined by examining the participant's shoes and noting the presence of a 'slip-resistant' marking on the sole. Restaurant managers reported the frequency of daily kitchen floor cleaning. Participants reported their slip experience and work hours weekly for up to 12 weeks. The survey materials were made available in three languages: English, Spanish and Portuguese. The associations between rate of slipping and risk factors were assessed using a multivariable negative binomial generalised estimating equation model. The mean of individual slipping rate varied among the restaurants from 0.02 to 2.49 slips per 40 work hours. After adjusting for age, gender, BMI, education, primary language, job tenure and restaurant chain, the use of slip-resistant shoes was associated with a 54% reduction in the reported rate of slipping (95% CI 37% to 64%), and the rate of slipping decreased by 21% (95% CI 5% to 34%) for each 0.1 increase in the mean kitchen COF. Increasing floor cleaning frequency was significantly associated with a decreasing rate of slipping when considered in isolation but not after statistical adjustment for other factors. These results provide support for the use of slip-resistant shoes and measures to increase COF as preventive interventions to reduce slips, falls and injuries.

  2. Cleaning devices

    NASA Technical Reports Server (NTRS)

    Schneider, Horst W. (Inventor)

    1981-01-01

    Cleaning devices are described which include a vacuum cleaner nozzle with a sharp rim for directing incoming air down against the floor; a vacuum cleaner wherein electrostatically charged brushes that brush dirt off a floor, are electrically grounded to remove charges that could tend to hold dirt to the brushes; a vacuum cleaner head having slots that form a pair of counter-rotating vortices, and that includes an outlet that blows a stream of air at the floor region which lies between the vortices; a cleaning device that sweeps a group of brushes against the ground along a first direction, and then sweeps them along the same ground area but in a second direction angled from the first by an amount such as 90.degree., to sweep up particles lying in crevices extending along any direction; a device that gently cleans a surface to remove bacteria for analysis, including an inclined wall along which cleaning fluid flows onto the surface, a vacuum chamber for drawing in the cleaning fluid, and a dividing wall spaced slightly from the surface to separate the fluid source from the vacuum cleaner chamber; and a device for providing pulses of pressured air including a chamber to which pressured air is supplied, a ball that circulates around the chamber to repeatedly close an outlet, and an air source that directs air circumferentially to move the ball around the chamber.

  3. A Few Easy Steps.

    ERIC Educational Resources Information Center

    Ellis, Tom

    2000-01-01

    Examines tested techniques that can keep a school's carpeting in good condition. Cleaning with hot water extraction, removing spills and spots, handling emergency cleanups, and cleaning soft surface flooring are addressed. (GR)

  4. FIRST FLOOR, A view from the northeast corner of the ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FIRST FLOOR, A view from the northeast corner of the clean room (Room 54) looking southwest - Department of Energy, Mound Facility, Isolated Building (I Building), One Mound Road, Miamisburg, Montgomery County, OH

  5. 30 CFR 56.20003 - Housekeeping.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... At all mining operations— (a) Workplaces, passageways, storerooms, and service rooms shall be kept clean and orderly; (b) The floor of every workplace shall be maintained in a clean and, so far as...

  6. 30 CFR 56.20003 - Housekeeping.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    .... At all mining operations— (a) Workplaces, passageways, storerooms, and service rooms shall be kept clean and orderly; (b) The floor of every workplace shall be maintained in a clean and, so far as...

  7. 30 CFR 56.20003 - Housekeeping.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    .... At all mining operations— (a) Workplaces, passageways, storerooms, and service rooms shall be kept clean and orderly; (b) The floor of every workplace shall be maintained in a clean and, so far as...

  8. 30 CFR 56.20003 - Housekeeping.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .... At all mining operations— (a) Workplaces, passageways, storerooms, and service rooms shall be kept clean and orderly; (b) The floor of every workplace shall be maintained in a clean and, so far as...

  9. 30 CFR 57.20003 - Housekeeping.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Housekeeping. At all mining operations— (a) Workplaces, passageways, storerooms, and service rooms shall be kept clean and orderly; (b) The floor of every workplace shall be maintained in a clean and, so far as...

  10. 30 CFR 57.20003 - Housekeeping.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Housekeeping. At all mining operations— (a) Workplaces, passageways, storerooms, and service rooms shall be kept clean and orderly; (b) The floor of every workplace shall be maintained in a clean and, so far as...

  11. 30 CFR 57.20003 - Housekeeping.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Housekeeping. At all mining operations— (a) Workplaces, passageways, storerooms, and service rooms shall be kept clean and orderly; (b) The floor of every workplace shall be maintained in a clean and, so far as...

  12. 30 CFR 57.20003 - Housekeeping.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Housekeeping. At all mining operations— (a) Workplaces, passageways, storerooms, and service rooms shall be kept clean and orderly; (b) The floor of every workplace shall be maintained in a clean and, so far as...

  13. 9 CFR 354.243 - Operations and procedures.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ...) The floors in the eviscerating room shall be kept clean and reasonably dry during eviscerating... handling equipment shall wear clean garments and should wear caps or hair nets, and shall keep their hands...

  14. Characterization of Cleaning and Disinfecting Tasks and Product Use Among Hospital Occupations

    PubMed Central

    Saito, Rena; Virji, M. Abbas; Henneberger, Paul K.; Humann, Michael J.; LeBouf, Ryan F.; Stanton, Marcia L.; Liang, Xiaoming; Stefaniak, Aleksandr B.

    2016-01-01

    Background Healthcare workers have an elevated prevalence of asthma and related symptoms associated with the use of cleaning/disinfecting products. The objective of this study was to identify and characterize cleaning/disinfecting tasks and products used among hospital occupations. Methods Workers from 14 occupations at five hospitals were monitored for 216 shifts, and work tasks and products used were recorded at five-minute intervals. The major chemical constituents of each product were identified from safety data sheets. Results Cleaning and disinfecting tasks were performed with a high frequency at least once per shift in many occupations. Medical equipment preparers, housekeepers, floor strippers/waxers, and endoscopy technicians spent on average 108–177 min/shift performing cleaning/disinfecting tasks. Many occupations used products containing amines and quaternary ammonium compounds for > 100 min/shift. Conclusions This analysis demonstrates that many occupations besides housekeeping incur exposures to cleaning/disinfecting products, albeit for different durations and using products containing different chemicals. PMID:25351791

  15. Cleaning practices and cleaning products in nurseries and schools: to what extent can they impact indoor air quality?

    PubMed

    Wei, W; Boumier, J; Wyart, G; Ramalho, O; Mandin, C

    2016-08-01

    In the framework of a nationwide survey on indoor air quality conducted from September 2009 to June 2011 in 310 nurseries, kindergartens, and elementary schools in all regions of France, cleaning practices and products were described through an extensive questionnaire completed on-site by expert building inspectors. The questionnaire included the cleaning frequencies and periods, cleaning techniques, whether windows were open during cleaning, and the commercial names of the products used. Analysis of the questionnaire responses showed that cleaning was generally performed daily for furniture and floors. It was performed mostly in the evening with wet mopping and with one or more windows open. Five hundred eighty-four different cleaning products were listed, among which 218 safety data sheets (SDSs) were available and analyzed. One hundred fifty-two chemical substances were identified in the SDSs. The typical substances in cleaning products included alcohols, chlorides, terpenes, aldehydes, and ethers; more than half of them are irritants. Two endocrine disruptors, 2-phenylphenol and Galaxolide, were identified in two cleaning products used every day to clean the floors, in seven kindergartens and in a nursery respectively. Eleven reactive substances containing C=C double bonds, mostly terpenes, were identified in a wide variety of cleaning products. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. 4. FIRST FLOOR SOUTH WALL, WITH PIPE MANIFOLDS AND (RIGHTCENTER) ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. FIRST FLOOR SOUTH WALL, WITH PIPE MANIFOLDS AND (RIGHT-CENTER) PORTABLE STEAM PUMP FOR PIPE MAINTENANCE AND CLEANING - Colgate & Company Jersey City Plant, Building No. B-3, 47-51 York Street, Jersey City, Hudson County, NJ

  17. 7 CFR 58.146 - Cleaning and sanitizing treatment.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... seal assemblies shall be removable on all agitators, pumps, and vats and shall be inspected at regular... above the floor in clean, dry locations and in a self draining position on racks constructed of...

  18. Generation of airborne listeria from floor drain

    USDA-ARS?s Scientific Manuscript database

    Listeria monocytogenes can colonize in floor drains in poultry processing plants and further throughout processing facilities, remaining present even after cleaning and disinfection of the plant. Therefore, during wash down, workers exercise caution to prevent escape and transfer of drain microflor...

  19. Roadmap to Implementing Green Cleaning in Districts and Schools

    ERIC Educational Resources Information Center

    Davis, Rochelle, Ed.

    2012-01-01

    Bill Thompson, Director of Facilities for Lockport Township High School in Illinois, first considered starting a green cleaning program after his janitors became dizzy when using a traditional chemical floor stripper. Thompson started introducing green products gradually at Lockport Township High, and now almost all of the cleaning agents used at…

  20. KENNEDY SPACE CENTER, FLA. - A KSC employee uses a clean-air shower before entering a clean room. Streams of pressurized air directed at the occupant from nozzles in the chamber's ceiling and walls are designed to dislodge particulate matter from hair, clothing and shoes. The adhesive mat on the floor captures soil from shoe soles, as well as particles that fall on its surface. Particulate matter has the potential to contaminate the space flight hardware being stored or processed in the clean room. The shower is part of KSC's Foreign Object Debris (FOD) control program, an important safety initiative.

    NASA Image and Video Library

    2003-08-29

    KENNEDY SPACE CENTER, FLA. - A KSC employee uses a clean-air shower before entering a clean room. Streams of pressurized air directed at the occupant from nozzles in the chamber's ceiling and walls are designed to dislodge particulate matter from hair, clothing and shoes. The adhesive mat on the floor captures soil from shoe soles, as well as particles that fall on its surface. Particulate matter has the potential to contaminate the space flight hardware being stored or processed in the clean room. The shower is part of KSC's Foreign Object Debris (FOD) control program, an important safety initiative.

  1. Improved system for floor cleaning in health care facilities.

    PubMed Central

    Schmidt, E A; Coleman, D L; Mallison, G F

    1984-01-01

    A new system has been developed for sanitizing floors in hospitals; this system replaces the traditional procedure of daily dusting and wet mopping with a disinfectant-detergent solution and periodic buffing . This new system relies on a sequence of procedures consisting of dust mopping using a chemically treated dust mop, machine buffing of a sprayed-on polymer treatment, and a second dust mopping . The effectiveness of the procedures was evaluated by means of surface sampling for bacterial contamination and air sampling for airborne bacteria and dust. The level of bacterial contamination on the floors was reduced by 93.6% by using the new system, compared with 79.8% by using the conventional process of dust mopping and wet mopping with a disinfectant solution. The levels of airborne bacteria during and after the individual procedures did not vary significantly from the initial level (123.6 CFU/per m3 of air). A survey of representative colonies from air samples revealed staphylococci, gram-positive bacilli, gram-positive diplococci, yeast cells, and infrequent gram-negative rods. The distribution at the conclusion of the sanitizing process was similar to that at the outset. Similarly, the levels of airborne dust measured during and after the individual procedures did not vary significantly from the initial level. When compared with the traditional method of cleaning by wet mopping , the new method was significantly more effective in removal of microbial contamination and required less labor. PMID:6742835

  2. Does Flooring Substrate Impact Kennel and Dog Cleanliness in Commercial Breeding Facilities?

    PubMed

    Stella, Judith; Hurt, Moriah; Bauer, Amy; Gomes, Paulo; Ruple, Audrey; Beck, Alan; Croney, Candace

    2018-04-21

    Evaluation of kennel flooring surfaces is needed to understand their impacts on dog health and well-being. This pilot study aimed to characterize aspects of physical health, kennel cleanliness, and dog body cleanliness on flooring types common in US breeding kennels. Subjects were 118 adult dogs housed on diamond-coated expanded metal (DCEM), polypropylene (POLY), or concrete (CON) flooring at five commercial breeding facilities in Indiana, U.S. Body condition, paw, elbow, and hock health scores were recorded. Each indoor kennel and dog was visually assessed for cleanliness. Kennels were swabbed immediately after cleaning with electrostatic dry cloths and cultured for Escherichia coli . Descriptive statistics were used for analysis. Mean body condition score (BCS), kennel and dog cleanliness scores were all near ideal (3, 1.15, and 1.04, respectively). Thirty-one percent or fewer kennels at each facility were culture-positive for E. coli after cleaning. No serious paw, elbow, or hock problems were identified. Overall, the findings indicate that with appropriate management and regular access to additional surfaces, dog foot health, cleanliness, and kennel cleanliness can be maintained on the flooring types investigated.

  3. Looking for Microbes in a Spacecraft Assembly Clean Room

    NASA Image and Video Library

    2013-11-06

    A microbiologist collects a swab sample from the floor of a spacecraft assembly clean room at NASA Jet Propulsion Laboratory where samples such as this are taken frequently during the assembly of a spacecraft and analyzed.

  4. Environmental monitoring in a laboratory animal facility.

    PubMed

    Wellstood-Nuesse, S; Shields, R P

    1976-08-01

    A study was made of the microbial environmental status of an animal facility. Cultures were made of animal and surgical room floors; the germicidal effectiveness of the phenolic disinfectant-detergent employed in the facility was tested against standard test organisms as well as against other microorganisms isolated from the facility, and killing power of the disinfectant-detergent was evaluated during various steps of the usual cleaning procedures, ie, mops and mop bucket solutions were tested before, during, and after mopping a room. It was found that colony counts for animal rooms cleaned with a chlorhexidine disinfectant were much lower than those cleaned with a phenolic disinfectant. The phenolic disinfectant killed some organisms after 10 min exposure, but no others. Pseudomonads were the most resistant organisms. Contaminated mops and mop bucket solutions appeared responsible for the high counts on floors cleaned with the phenolic disinfectant. Guidelines for achievable levels of cleanliness were suggested.

  5. Development of a Method for Evaluating Floor Dry-Cleanability from Wheat Flour in the Food Industry.

    PubMed

    Barreca, F; Cardinali, G D; Borgese, E; Russo, M

    2017-04-01

    Many productive processes are characterized by inadequate protocols of sanitation that increase the possibility of proliferation of microbial contaminants, especially on surfaces. The use of this method for evaluating the degree of floor cleanability in agri-food companies is important not only to reduce the risk of contamination of products, but also to provide companies with a tool to identify critical issues. The method is based on the usage of bicinchoninic acid assay (BCA) in a solution at a 1:50 ratio of Cu 2+ /BCA, which is ideal for detecting the amount of proteins contained in wheat flour residues on industrial flooring. Spectrophotometric analysis allowed identifying maximum absorbance values at 562 nm for different protein concentrations, although the construction of a regression function led to the definition of the intervals of evaluation corresponding to different degrees of cleanliness from residues of wheat flour. The results of the absorbance curves, obtained by applying the proposed evaluation method to 6 tiles commonly used in agri-food buildings, showed the clear persistence of food material on 2 tiles with surface relief. In particular, such tiles showed a higher presence of proteins, with a level of contamination 440% higher. Furthermore, a robotic system was designed to standardize the cleaning method commonly employed in agri-food companies to remove solid particles from flooring. © 2017 Institute of Food Technologists®.

  6. Flooring choices for newborn ICUs.

    PubMed

    White, R D

    2007-12-01

    Floors are a major element of newborn intensive care unit (NICU) construction. They provide visual cues, sound control, and with certain materials, some degree of physical comfort for workers. Flooring materials may entail a significant cost for installation and upkeep and can have substantial ecological impact, both in the choice of the flooring itself, as well as the substances used to clean it. In this article the important aspects to consider for each factor are explored and recommendations are offered for appropriate choices in various NICU areas.

  7. 77 FR 1111 - Self-Regulatory Organizations; NASDAQ OMX PHLX LLC; Notice of Filing and Immediate Effectiveness...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-09

    ... equity trading system. The Exchange ceased operation of the technology used to operate XLE on October 24... cleaning, HVAC and general maintenance. All other floor members would be assessed the Floor Facility Fee of...

  8. Effect of cage vs. floor litter environments on the pulmonary hypertensive response to intravenous endotoxin and on blood-gas values in broilers.

    PubMed

    Wang, W; Erf, G F; Wideman, R F

    2002-11-01

    Intravenous endotoxin has been shown to trigger a delayed pulmonary hypertensive response that varies widely in magnitude and duration among individual broilers. It was proposed that this individual variability may reflect immunological differences acquired during previous respiratory challenges that might have subsequently altered the endotoxin-initiated biochemical cascade. In Experiment 1, we tested the hypothesis that, when compared with broilers reared in clean stainless steel cages (Cage group), broilers reared on floor litter (Floor group) should experience a greater respiratory challenge and therefore may consistently exhibit a more enhanced pulmonary hypertensive response to intravenous endotoxin. Birds in the Cage group were grown in stainless steel cages at a low density (72 birds/8 m2 chamber), and fecal and dander materials were removed daily. Birds in the Floor group were reared on wood-shavings litter at a higher density (110 birds/8 m2 chamber). Pulmonary and systemic mean arterial pressures and blood-gas values were evaluated prior to and following the intravenous administration of 1 mg Salmonella typhimurium endotoxin. Broilers in the Floor and Cage groups exhibited pulmonary hypertensive responses to endotoxin that were very similar in terms of time of onset, duration, and magnitude, as well as variability in the response among individuals. Systemic hypotension also developed similarly in both groups following endotoxin injection. Blood-gas values indicated that the partial pressure of CO2 and the HCO3- concentration in arterial blood were higher (P < 0.05) in the Floor group than in the Cage group prior to and subsequent to the endotoxin injection. In Experiment 2, we reevaluated the effect of a dirty vs. a clean environment on blood-gas values using a different strain of broilers, and confirmed the negative impact of floor rearing on blood-gas values. We conclude that broilers reared on the floor inhaled litter dust and noxious fumes, which impaired pulmonary gas exchange and increased the arterial partial pressure of CO2 when compared with broilers reared in clean stainless steel cages. Nevertheless, the pulmonary hypertensive response to endotoxin did not differ between broilers reared on the floor and those in cages.

  9. Safety by design: effects of operating room floor marking on the position of surgical devices to promote clean air flow compliance and minimise infection risks.

    PubMed

    de Korne, Dirk F; van Wijngaarden, Jeroen D H; van Rooij, Jeroen; Wauben, Linda S G L; Hiddema, U Frans; Klazinga, Niek S

    2012-09-01

    To evaluate the use of floor marking on the positioning of surgical devices within the clean air flow in an operating room (OR) to minimise infection risk. Laminar flow clean air systems are important in preventing infection in ORs but, for optimal results, surgical devices must be correctly positioned. The authors evaluated floor marking in four ORs at an eye hospital using time series analysis. Through observations during 829 surgeries over a 20-month period, the positions of surgical devices were determined. Eight semistructured interviews with surgical staff were conducted to assess user experiences and team dynamics. Before marking, the instrument table was positioned completely within the laminar flow in only 6.1% of the cases. This increased to 36.1% and finally 53.8%. Mayo stands were increasingly positioned within the laminar flow: from 74.2% to 84.7%. The surgical lamp decreasingly obstructed flow: from 41.8% to 28.7%. At T3 (20 months), however, in 48.6% of the applicable cases the lamp was positioned in the flow again. Discussions and site visits between airside operators and surgical staff resulted in increasing awareness of specific risk areas in the OR. OR floor markings facilitated and stimulated safety awareness and resulted in significantly increased compliance with the positioning of surgical devices in the clean air flow. Safety and quality approaches in hospital care, therefore, should include a human factors approach that focuses on system design in addition to teaching clinical and non-technical skills.

  10. Digging up the Dirt.

    ERIC Educational Resources Information Center

    Knuffman, Susan M.

    1997-01-01

    Explores ways of maintaining school floors and carpeting that ensure students and staff are comfortable, safe, and healthy. Carpet maintenance for high- to low-traffic areas and cleaning procedures are examined, as are ways maintenance staff can work together to help ensure a successful flooring-maintenance plan. (GR)

  11. Seeing Results in Flooring for Schools

    ERIC Educational Resources Information Center

    Simmons, Brian

    2011-01-01

    Operations staffs at education facilities of all sizes are tasked with selecting a hard floor cleaning program that is cost-effective, efficient and highly productive. With an increased focus on the sustainability of an environment, facility managers also must select a program that meets sustainability goals while maintaining a healthful, safe…

  12. Potential of spreading binucleate Rhizoctonia from nursery propagation floors to trays containing azalea stem cuttings

    USDA-ARS?s Scientific Manuscript database

    Binucleate Rhizoctonia fungi cause web blight on azaleas and other woody ornamental plants. This research focused on one aspect of how the pathogen may spread from contaminated floors of propagation houses into trays containing clean azalea stem cuttings that generate new root systems. Rhizoctonia w...

  13. Occupational factors and pancreatic cancer.

    PubMed Central

    Norell, S; Ahlbom, A; Olin, R; Erwald, R; Jacobson, G; Lindberg-Navier, I; Wiechel, K L

    1986-01-01

    The relation between occupational factors and pancreatic cancer has been studied by two different approaches: a population based case-control study with two series of controls and a retrospective cohort study based on register data. With both approaches, some support was found for an association with occupational exposure to petroleum products. Associations were also indicated with exposure to paint thinner (case-control study) and work in painting and in paint and varnish factories (cohort study), for exposure to detergents, floor cleaning agents, or polish (case-control study) and with floor polishing or window cleaning (cohort study), and for exposure to refuse (case-control study) and work in refuse disposal plants (cohort study). PMID:3790458

  14. Case study of a floor-cleaning robot

    NASA Astrophysics Data System (ADS)

    Branch, Allan C.

    1998-01-01

    Developing the technologies suitable of ra high level robotic application such as cleaning a floor has proved extremely difficult. Developing the robot mobility technology has been a stumbling block and developing and integrating the applications technology to the machine and the mobility technology has also been a difficult stage in this quest, but doing so in a cost effective and realistic manner suitable for the market place and to compete with humans and manually operated machines has been the most difficult of all. This paper describes one of these quests spanning a 14 year period and resulting in what is hoped will be the world's first commercially manufactured household robot vacuum cleaner.

  15. 76 FR 26336 - Notice of Request for Approval of an Information Collection

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-06

    .... 5308--Clean Fuels Grant Program. DATES: Comments must be submitted before July 5, 2011. ADDRESSES: To...., Docket Operations, M-30, West Building, Ground Floor, Room W12- 140, Washington, DC 20590-0001. 4. Hand... Building, Ground Floor, Room W12-140, Washington, DC 20590-0001 between 9 a.m. and 5 p.m., Monday through...

  16. Thumbnail Sketches: EDTA-Type Chelating Agents in Everyday Consumer Products: Some Food, Cleaning, and Photographic Applications.

    ERIC Educational Resources Information Center

    Hart, J. Roger

    1985-01-01

    Discusses the role of chelating agents in (1) mayonnaise and salad dressings; (2) canned legumes; (3) plant foods; (4) liquid dishwashing detergents; (5) toilet soaps; (6) floor wax removers; (7) hard surface cleaners; (8) carpet cleaning; (9) bathtub and tile cleaners; and (10) photography. (JN)

  17. Biosecurity and Circulation of Influenza A (H5N1) Virus in Live-Bird Markets in Bangladesh, 2012.

    PubMed

    Biswas, P K; Giasuddin, M; Nath, B K; Islam, M Z; Debnath, N C; Yamage, M

    2017-06-01

    Bangladesh has been considered as one of the five countries endemic with highly pathogenic avian influenza A subtype H5N1 (HPAI H5N1). Live-bird markets (LBMs) in south Asian countries are believed to play important roles in the transmission of HPAI H5N1 and others due to its central location as a hub of the poultry trading. Food and Agriculture Organization (FAO) of the United Nations has been promoting improved biosecurity in LBMs in Bangladesh. In 2012, by enrolling 32 large LBMs: 10 with FAO interventions and 22 without assistance, we assessed the virus circulation in the selected LBMs by applying standard procedures to investigate market floors, poultry stall floors, poultry-holding cases and slaughter areas and the overall biosecurity using a questionnaire-based survey. Relative risk (RR) was examined to compare the prevalence of HPAI H5N1 in the intervened and non-intervened LBMs. The measures practised in significantly more of the FAO-intervened LBMs included keeping of slaughter remnants in a closed container; decontamination of poultry vehicles at market place; prevention of crows' access to LBM, market/floor cleaning by market committee; wet cleaning; disinfection of floor/poultry stall after cleaning; and good supply of clean water at market (P < 0.05). Conversely, disposal of slaughter remnants elsewhere at market and dry cleaning were in operation in more of the FAO non-intervened LBMs (P < 0.05). The RR for HPAI H5N1 in the intervened and non-intervened LBMs was 1.1 (95% confidence interval 0.44-2.76), suggesting that the proportion positive of the virus in the two kinds of LBM did not vary significantly (P = 0.413). These observations suggest that the viruses are still maintained at the level of production in farms and circulating in LBMs in Bangladesh regardless of interventions, albeit at lower levels than in other endemic countries. © 2015 Blackwell Verlag GmbH.

  18. Characterization of biogenic volatile organic compounds (BVOCs) in cleaning reagents and air fresheners in Hong Kong

    NASA Astrophysics Data System (ADS)

    Huang, Yu; Ho, Steven Sai Hang; Ho, Kin Fai; Lee, Shun Cheng; Gao, Yuan; Cheng, Yan; Chan, C. S.

    2011-11-01

    Biogenic volatile organic compounds (BVOCs) emitted from cleaning products and air fresheners indoors are prone to oxidation resulting in the formation of secondary pollutants that can pose health risks on residents. In this study, a solid phase microextraction (SPME) coupled with gas chromatography/mass spectrometry (SPME-GC/MS) method was applied for the determination of BVOCs compositions in three categories of cleaning products including floor cleaners (FC), kitchen cleaners (KC) and dishwashing detergents (DD), and also air fresheners (AF). The analysis results demonstrated that chemical composition and concentration of individual BVOC varied broadly with household products in the view of their different functions and scents as indicated on the labels. The concentration of total BVOCs for sample FC1 was the highest up to 4146.0 μg g -1, followed by FC2 of 264.6 μg g -1, FC4 of 249.3 μg g -1 and FC3 of 139.2 μg g -1. D-limonene was the most abundant detected BVOCs in KC samples with the chemical composition varying from 19.6 ± 1.0 to 1513.0 ± 37.1 μg g -1. For dishwashing detergents, only D-limonene was detected and quantified. The BVOCs compositions of air freshener samples are much more complicated. It was estimated that the consumption of floor cleaners contributed 51% of the total BVOCs amount indoors in Hong Kong, followed by air fresheners 42%, kitchen cleaners 5% and dishwashing detergents 2%.

  19. Gas chromatography with mass spectrometry for the quantification of ethylene glycol ethers in different household cleaning products.

    PubMed

    Pastor-Belda, Marta; Campillo, Natalia; Hernández-Córdoba, Manuel; Viñas, Pilar

    2016-06-01

    A rapid and simple procedure is reported for the determination of six ethylene glycol ethers in cleaning products and detergents using gas chromatography with mass spectrometry. The analytes were extracted from 2.0 g samples in acetonitrile (3 mL) and the extract was submitted to a clean-up step by QuEChERS method, using a mixture containing 0.3 g magnesium sulfate, 0.15 g primary/secondary amine, and 0.05 g C18 . The clean acetonitrile extract (1 μL) was injected into the chromatographic system. No matrix effect was observed, so the quantification of the samples was carried out against external standards. Detection limits were in the range 3.0-27 ng/g for the six ethylene glycol ethers. The recoveries obtained, using the optimized procedure, were in the 89.4-118% range, with relative standard deviations lower than 14%. Twenty-three different household cleaning products, including glass cleaner, degreaser, floor, softeners, and clothes and dishwashing detergents, were analyzed. Large interindividual variations were observed between samples and compounds. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Chemical Products in the Home, Workshop and Garden. Proceed with Caution; Consumer Safety in the Home, II.

    ERIC Educational Resources Information Center

    Saskatchewan Consumer and Commercial Affairs, Regina.

    The average home has chemical products to clean floors, kill insects, clean ovens, thin paint, remove grease, and perform countless other chores. Many consumers remain unaware of the dangers these products bring into the home. This booklet provides information on the safe use, storage, and disposal of these products. The compounds found in…

  1. Price Update Methodology for Use in Maintenance Expenditure Limits (MEL) for Secondary Items.

    DTIC Science & Technology

    1984-11-01

    CD 7130 Recreational & Gymnastic Equipment ................................................... CD 7910 Floor Polishers & Vacuum Cleaning Equipment...CD 8l. ) Paint & Artists Brushes .......... .................................................... CD 8 3 Preservative

  2. Athlete's Foot

    MedlinePlus

    ... damp surfaces, such as showers, swimming pools, and locker room floors. To prevent it Keep your feet ... barefoot in public areas Wear flip-flops in locker room showers Keep your toenails clean and clipped ...

  3. Identification of Clostridium difficile Reservoirs in The Patient Environment and Efficacy of Aerial Hydrogen Peroxide Decontamination.

    PubMed

    Yui, Samuel; Ali, Shanom; Muzslay, Monika; Jeanes, Annette; Wilson, A Peter R

    2017-12-01

    OBJECTIVE To identify, using a novel enhanced method of recovery, environmental sites where spores of Clostridium difficile persist despite cleaning and hydrogen peroxide aerial decontamination. DESIGN Cohort study. SETTING Tertiary referral center teaching hospital. METHODS In total, 16 sites representing high-frequency contact or difficult-to-clean surfaces in a single-isolation room or bed area in patient bed bays were sampled before and after terminal or hydrogen peroxide disinfection using a sponge swab. In some rooms, individual sites were not present (eg, there were no en-suite rooms in the ICU). Swab contents were homogenized, concentrated by membrane-filtration, and plated onto selective media. Results of C. difficile sampling were used to focus cleaning. RESULTS Over 1 year, 2,529 sites from 146 rooms and 44 bays were sampled. Clostridium difficile was found on 131 of 572 surfaces (22.9%) before terminal cleaning, on 105 of 959 surfaces (10.6%) after terminal cleaning, and on 43 of 967 surfaces (4.4%) after hydrogen peroxide disinfection. Clostridium difficile persisted most frequently on floor corners (97 of 334; 29.0%) after disinfection. Between the first and third quarters, we observed a significant decrease in the number of positive sites (25 of 390 vs 6 of 256). However, no similar change in the number of isolates before terminal cleaning was observed. CONCLUSION Persistence of C. difficile in the clinical environment was widespread. Although feedback of results did not improve the efficacy of manual disinfection, numbers of C. difficile following hydrogen peroxide gradually declined. Infect Control Hosp Epidemiol 2017;38:1487-1492.

  4. Assessment of materials commonly utilized in health care: implications for bacterial survival and transmission.

    PubMed

    Lankford, Mary G; Collins, Susan; Youngberg, Larry; Rooney, Denise M; Warren, John R; Noskin, Gary A

    2006-06-01

    Contaminated environmental surfaces, equipment, and health care workers' hands have been linked to outbreaks of infection or colonization because of vancomycin-resistant enterococci (VRE) and Pseudomonas aeruginosa (PSAE). Upholstery, walls, and flooring may enhance bacterial survival, providing infectious reservoirs. Investigate recovery of VRE and PSAE, determine efficacy of disinfection, and evaluate VRE transmission from surfaces. Upholstery, flooring, and wall coverings were inoculated with VRE and PSAE and assessed for recovery at 24 hours, 72 hours, and 7 days. Inoculated surfaces were cleaned utilizing manufacturers' recommendations of natural, commercial, or hospital-approved products and methods, and samples were obtained. To assess potential for transmission, volunteers touched VRE-inoculated surfaces and imprinted palms onto contact-impression plates. Twenty-four hours following inoculation, all surfaces had recovery of VRE; 13 (92.9%) of 14 surfaces had persistent PSAE. After cleaning, VRE was recovered from 7 (50%) surfaces, PSAE from 5 (35.7%) surfaces. After inoculation followed by palmar contact, VRE was recovered from all surfaces touched. Bacteria commonly encountered in hospitals are capable of prolonged survival and may promote cross transmission. Selection of surfaces for health care environments should include product application and complexity of manufacturers' recommendations for disinfection. Recovery of organisms on surfaces and hands emphasizes importance of hand hygiene compliance prior to patient contact.

  5. The Sweet Smell of Success.

    ERIC Educational Resources Information Center

    Huddleston, Elizabeth

    2001-01-01

    Examines how careful attention to the design and maintenance of locker rooms can not only contain odors, but greatly enhance a facility's image. Locker systems, flooring options, ventilation, and cleaning regimens are addressed. (GR)

  6. 9 CFR 89.5 - Feeding pens.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... resting livestock in transit should have (1) sufficient space for all of the livestock to lie down at the...-drained, clean, and safe floors of concrete, cinders, gravel, hard-packed earth, or other suitable...

  7. Effect of intravenous endotoxin on blood cell profiles of broilers housed in cages and floor litter environments.

    PubMed

    Wang, W; Wideman, R F; Chapman, M E; Bersi, T K; Erf, G F

    2003-12-01

    Commercial broilers are constantly exposed to airborne microorganisms and endotoxin (lipopolysaccharide, LPS). It has been shown that microbial contamination of the air was higher in broiler houses using floor litter than in broiler houses using netting-type floors. The current study evaluated the effect of housing conditions on blood leukocyte profiles and tested the hypothesis that, when compared to broilers reared in clean stainless steel cages (Cage group), broilers raised on floor litter (Floor group) should experience a higher environmental challenge and have a desensitized immune system that may exhibit better tolerance/resistance to subsequent intravenous LPS challenge. Hematological parameters were evaluated prior to and following i.v. administration of 1 mg/kg BW Salmonella typhimurium LPS (dissolved at 1 mg/0.25 mL in PBS) or i.v. injection of 0.25 mL/kg BW PBS alone. The results showed that prior to LPS/PBS injection, broilers in the cage group had higher heterophil and monocyte concentrations, a higher B cell percentage within the lymphocyte population, and a higher heterophil to lymphocyte (H:L) ratio in the blood. The i.v. LPS injection resulted in 25% mortality in the cage group and 42% mortality in the floor group within 8 h post-injection. LPS reduced the concentrations of total white blood cells (WBC) and all differential WBC except eosinophils and increased thrombocyte concentrations within 1 h post-injection in both groups. All of these values returned to their respective pre-injection levels within 48 h post-injection in the surviving birds. The two groups exhibited similar overall hematological changes after LPS injection except that the cage group showed a higher H:L ratio at 8 h post-injection and a lower B-cell percentage within the lymphocyte population at 48 h post-injection when compared with the floor group. We concluded that the immune systems of broilers reared on floor litter were desensitized and exhibited less pronounced leukocyte responses to i.v. LPS when compared with those of broilers reared in clean stainless steel cages. However, such desensitization of the immune system did not help broilers survive subsequent i.v. LPS challenge.

  8. Cleaning Up.

    ERIC Educational Resources Information Center

    Musgrave, Chuck; Spencer-Workman, Sarah

    2000-01-01

    Provides a nine-step process in designing athletic facility laundry rooms that are attractive and functional. Steps include determining the level of laundry services needed, ensuring adequate storage and compatible delivery systems, selecting laundry equipment, and choosing suitable flooring. (GR)

  9. Specifying to meet multiple demands.

    PubMed

    West, Martyn

    2014-04-01

    Choosing flooring for healthcare takes careful consideration. New legislation in healthcare places greater responsibility on those throughout the supply chain to ensure the safety of staff, visitors, and patients - now, and in the future. This undoubtedly impacts on flooring choices, but there is also the need for the most stringent hygiene, an aesthetically pleasing healing environment, maintenance and cleaning considerations, environmental impact, and some very specific requirements for dementia and elderly care to consider. Martyn West, Altro's specification manager, examines these key issues.

  10. Commander Truly cleans ARS filters on middeck

    NASA Image and Video Library

    1983-09-05

    STS008-13-336 (5 Sept 1983) --- On middeck, Richard M. Truly, STS-8 commander, uses vacuum cleaner to remove debris from air revitalization system (ARS) filter assembly. Open panel on middeck floor is the ARS access panel.

  11. Effect of housing conditions (clean vs. dirty) on growth performance and feeding behavior in growing pigs in a tropical climate.

    PubMed

    Renaudeau, D

    2009-04-01

    The effect of bad sanitary conditions on growth performance and feeding behaviour were studied on a total of 48 Large White pigs between 95 and 130 d of age. This experiment carried out during the hot season in a tropical humid climate. Two groups of 12 pigs each were housed in a clean environment in which the pens were disinfected thoroughly prior to stocking and maintained in a clean state by daily washing the pens and by weekly emptying the manure stored beneath the partial concrete floor. The dirty environment was achieved by not cleaning the pens prior to stocking or throughout the experiment and by storing the manure beneath the floor slats throughout the experimental period. The microbial pressure was increased by introducing 5 additional non experimental pigs near each experimental dirty pen. Feeding behaviour parameters were measured using automatic feed dispensers. Pigs housed in a clean environment consumed more feed (2.283 vs. 1.953 kg/d; P < 0.001) and grew faster (871 vs. 780 g/d; P < 0.05) than those housed in the dirty environment. No significant effect on treatment was reported for the feed conversion efficiency (2.70 kg/kg on average). The reduced average daily feed intake in dirty pens was associated with a reduction of the meal size (334 vs. 282 g/meal; P = 0.10) whereas the meal frequency was not affected by treatment (7.5 meals/d on average). The rate of feed intake was significantly higher in the clean than in the dirty environment (34.0 vs. 29.9 g/min; P < 0.05).

  12. The Real Dirt on Carpets.

    ERIC Educational Resources Information Center

    Lang, Susan S.

    2001-01-01

    Argues that carpets do not contribute to student complaints of respiratory problems, allergies, and asthma as long as they are properly cleaned with high-efficiency microfiltration bags. Discusses contributions to mite problems made by smooth floor covering compared to carpeting. (GR)

  13. Health, safety, and ecological implications of using biobased floor-stripping products.

    PubMed

    Massawe, Ephraim; Geiser, Kenneth; Ellenbecker, Michael; Marshall, Jason

    2007-05-01

    The main objective of the study reported here was to investigate the ecological, health, and safety (EHS) implications of using biobased floor strippers as alternatives to solvent-based products such as Johnson Wax Professional (Pro Strip). The authors applied a quick EHS-scoring technique developed by the Surface Solution Laboratory (SSL) of the Toxics Use Reduction Institute (TURI) to some alternative, biobased products that had previously performed as well as or close to as well as the currently used product. The quick technique is considered an important step in EHS assessment, particularly for toxics use reduction planners and advocates who may not have the resources to subject many alternative products or processes at once to detailed EHS analysis. Taking this step narrows available options to a manageable number. (Technical-performance experiments were also conducted, but the results are not discussed or reported in this paper). The cost of switching to biobased floor strippers was assessed and compared with the cost of using the traditional product, both at full strength and at the dilution ratios recommended by the respective manufacturers. The EHS analysis was based on a framework consisting of five parameters: volatile organic compounds (VOCs); pH; global-warming potential (GWP); ozone depletion potential (ODP); and safety scores in areas such as flammability, stability, and special hazards, based on ratings from the Hazardous Material Classification System (HMIS) and the National Fire Protection Association (NFPA). Total EHS scores were calculated with data derived from the material safety data sheets. For most cleaning products previously investigated by the TURI SSL, the investigators have demonstrated that the five key parameters used in the study reported here can successfully be used for quick screening of the EHS impacts of cleaning alternatives. All eight biobased, or green, products evaluated in the study had better EHS-screening scores than did Pro Strip. One product, Botanic Gold, had a screening score of 49 out of a possible 50. This score was much higher than the score of 26 achieved by Pro Strip. The other biobased floor strippers had EHS-screening scores of > or =37, which is the average value of solvent-based cleaning solutions. These results indicate that biobased cleaning products capable of floor stripping are potentially better than traditional products with respect to the five EHS parameters used. The cost of switching to biobased floor strippers at their full strength ranged from a minimum of U.S. $15.50 per gallon ($4.10 per liter) for Eco Natural Floor Stripper (WPR) to about $59.00 per gallon ($15.61 per liter) for Botanic Gold. At 25 percent volume by volume (v/v), the recommended dilution ratio for the traditional product, the cost of the Botanic Gold was $14.75 per gallon ($3.90 per liter), or about five times more than that of Pro Strip, which was $2.48 per gallon ($0.65 per liter). Since these figures do not reflect all of the EHS costs, such as disposal and recycling fees, it is likely that use of Botanic Gold could be cost-effective in the long run. The authors therefore recommend that detailed EHS analysis be conducted on this alternative biobased floor stripper. It is also recommended that large field trials be conducted and that janitors' or consumers' perceptions be determined. For detailed assessment of eco-toxicological properties of the biobased floor strippers, investigations of the common additives in the Botanic Gold formulation should be conducted through use of databases on the World Wide Web such as Toxnet. Finally, the current policies, regulations, and standards that promote biobased products should be investigated to determine their strengths and weaknesses. This would encourage a broader public debate about the future of the biobased industry in the context of sustainability.

  14. Carpeting/Flooring: Revitalizing Carpets.

    ERIC Educational Resources Information Center

    Woolford, Alison; Hill, Michael

    2003-01-01

    With properly specified fiber and a comprehensive maintenance program, school carpets can retain their appearance longer. Discusses carpet characteristics; proper carpet installation; effective preventive-maintenance programs (keep outside areas clean, use soil barriers, protect desk areas, maintain HVAC systems, and specify eating, drinking, and…

  15. STS-30 Magellan spacecraft processing at Kennedy Space Center (KSC) SAEF-2

    NASA Technical Reports Server (NTRS)

    1989-01-01

    Magellan spacecraft is hoisted from the transport trailer of the Payload Environmental Transportation System (PETS) to the floor of the clean room in the Space Assembly and Encapsulation Facility 2 (SAEF-2) at Kennedy Space Center (KSC). Clean-suited technicians guide Magellan into place. The spacecraft, destined for unprecedented studies of Venusian topographic features, will be deployed by the crew of NASA's STS-30 mission in April 1989. View provided by KSC with alternate number KSC-88PC-1084.

  16. The effects of different flooring types on the behavior, health, and welfare of finishing beef steers.

    PubMed

    Elmore, M R P; Elischer, M F; Claeys, M C; Pajor, E A

    2015-03-01

    Raising beef cattle on concrete floors can negatively impact their welfare by increasing joint swelling and body lesions, as well as abnormalities in resting behavior and postural changes. We hypothesized that the addition of rubber mats to concrete pens would improve beef cattle welfare by improving performance, health, hygiene, and resting behavior. Forty-eight crossbred Angus steers were housed in pens of 4 and randomly assigned to a single flooring treatment: (1) fully slatted concrete (CON), (2) fully slatted rubber mat (SLAT), or (3) solid rubber mat (SOLID; 60% of pen floor) from 36 to 48 wk of age. Weight, ADG, lesions, gait score, joint swelling, and animal and pen cleanliness were collected every 2 wk. Behavioral time budgets and frequency of postural changes (an indicator of floor traction and comfort) were collected at 0, 6, and 12 wk. No differences in weight gain or ADG were observed. Steers on SOLID flooring (0.80 ± 0.08) showed increased lesions compared to SLAT (0.38 ± 0.08) and CON (0.37 ± 0.08; both, = 0.05); however, there was no difference between SLAT and CON. SLAT steers (1.69 ± 0.04) showed a reduced gait score compared to SOLID (1.95 ± 0.04) and CON (1.98 ± 0.04; both, < 0.05), but SOLID and CON did not differ. Steers on SLAT flooring had less joint swelling (both knees and hocks) compared to SOLID and CON (all comparisons, < 0.05), but SOLID and CON did not differ. Steers on SOLID (3.64 ± 0.05) flooring were dirtier than those on SLAT (2.27 ± 0.05) and CON (2.19 ± 0.05; both, < 0.001), whereas SLAT and CON were similar. Additionally, SOLID and SLAT pens were less clean than CON pens ( < 0.001 and = 0.094, respectively), and SOLID was less clean than SLAT ( < 0.001). Time budget behavior was affected by treatment ( = 0.043), where SOLID differed from CON and SLAT (both, < 0.05). Steers on SOLID flooring preferred to rest on the rubber mat vs. slatted concrete ( = 0.001). Steers on SLAT flooring changed their posture more frequently than those on SOLID and CON flooring (both, < 0.05), but SOLID and CON did not differ. Compared to CON steers, SOLID steers showed an increase in lesions and a reduction in cleanliness, whereas SLAT steers showed a decrease in gait score and joint swelling and an increase in postural changes. Combined, these data suggest that the addition of slatted rubber mats to concrete pens may improve beef cattle welfare.

  17. 76 FR 19476 - Exelon Generation Company, LLC, Peach Bottom Atomic Power Station, Unit Nos. 2 and 3; Exemption

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-07

    ... licensee stated that the floor-based combustibles include health physics cleaning supplies, such as mops... undue risk to public health or safety, and are consistent with the common defense and security; and (2...

  18. Targeted Cleaning.

    ERIC Educational Resources Information Center

    Frank, David J.

    1998-01-01

    Discusses the creation of an effective carpet vacuuming program by combining area usage assessment and vacuuming requirements with a scheduling plan. Also explains vacuum cleaner suction and filtration and how it makes custodian work more efficient. A complementary article discusses creating an effective floor-maintenance plan for resilient…

  19. 77 FR 32133 - National Register of Historic Places; Notification of Pending Nominations and Related Actions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-31

    ..., 1201 Eye St. NW., 8th floor, Washington, DC 20005; or by fax, 202-371-6447. Written or faxed comments... CAROLINA Durham County Scott and Roberts Dry Cleaning Plant, Office, and Store, 733 Foster St., Durham...

  20. The Fungus among Us.

    ERIC Educational Resources Information Center

    Weidner, Robert H.

    2003-01-01

    Offers tips for fighting mold in schools, asserting that it can contribute significantly to poor indoor air quality and sick building syndrome. Offers an overview on mold and discusses the steps of: humidity control, building inspections, condensation control or removal, and floor and carpet cleaning. (EV)

  1. Implementation of a solvent management program to control paint shop volatile organic compounds

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Floer, M.M.; Hicks, B.H.

    1997-12-31

    The majority of automobile assembly plant volatile organic compound (VOC) emissions are generated from painting operations. Typical paint operations generate more than 90 percent of the total plant emissions and, up to, 50 percent can be released by cleaning sources. Plant practices which contribute to the release of VOC emissions include the cleaning of paint lines and equipment, tanks, spray booths, floors and vehicles. Solvents continue to be the largest contributing source of VOC emissions in an automotive paint shop. To reduce overall VOC emissions, environmental regulations and guidelines were introduced under the Clean Air Act; Pollution Prevention and Wastemore » Minimization programs, Control Techniques, and special air permit conditions. The introduction of these regulations and guidelines has driven industry toward continual refinement of their present cleaning methods while pursuing new techniques and technologies. Industry has also shown a proactive approach by introducing new waterborne and powder coating paint technologies to reduce overall emissions. As new paint technologies are developed and introduced, special attention must be given to the types of materials utilized for cleaning. The development and implementation of a solvent management program allows a facility to standardize a program to properly implement materials, equipment, technologies and work practices to reduce volatile organic compound emissions, meet strict cleaning requirements posed by new paint technologies and produce a vehicle which meets the high quality standards of the customer. This paper will assess the effectiveness of a solvent management program by examining pollution prevention initiatives and data from four different painting operations.« less

  2. A first generation dynamic ingress, redistribution and transport model of soil track-in: DIRT.

    PubMed

    Johnson, D L

    2008-12-01

    This work introduces a spatially resolved quantitative model, based on conservation of mass and first order transfer kinetics, for following the transport and redistribution of outdoor soil to, and within, the indoor environment by track-in on footwear. Implementations of the DIRT model examined the influence of room size, rug area and location, shoe size, and mass transfer coefficients for smooth and carpeted floor surfaces using the ratio of mass loading on carpeted to smooth floor surfaces as a performance metric. Results showed that in the limit for large numbers of random steps the dual aspects of deposition to and track-off from the carpets govern this ratio. Using recently obtained experimental measurements, historic transport and distribution parameters, cleaning efficiencies for the different floor surfaces, and indoor dust deposition rates to provide model boundary conditions, DIRT predicts realistic floor surface loadings. The spatio-temporal variability in model predictions agrees with field observations and suggests that floor surface dust loadings are constantly in flux; steady state distributions are hardly, if ever, achieved.

  3. 29 CFR 1917.153 - Spray painting (See also § 1917.2, definition of Hazardous cargo, materials, substance, or...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... partition. (ii) Hot surfaces shall not be located in spraying areas. (iii) Whenever combustible residues may... cleaning, paper may be used to cover the floor during painting operations if it is removed after the...

  4. 29 CFR 1917.153 - Spray painting (See also § 1917.2, definition of Hazardous cargo, materials, substance, or...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... partition. (ii) Hot surfaces shall not be located in spraying areas. (iii) Whenever combustible residues may... cleaning, paper may be used to cover the floor during painting operations if it is removed after the...

  5. 29 CFR 1917.153 - Spray painting (See also § 1917.2, definition of Hazardous cargo, materials, substance, or...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... partition. (ii) Hot surfaces shall not be located in spraying areas. (iii) Whenever combustible residues may... cleaning, paper may be used to cover the floor during painting operations if it is removed after the...

  6. 29 CFR 1917.153 - Spray painting (See also § 1917.2, definition of Hazardous cargo, materials, substance, or...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... partition. (ii) Hot surfaces shall not be located in spraying areas. (iii) Whenever combustible residues may... cleaning, paper may be used to cover the floor during painting operations if it is removed after the...

  7. Hard Facts.

    ERIC Educational Resources Information Center

    Shaw, Richard

    1998-01-01

    Discusses the selection of floor-care equipment so that the equipment's features and performance attributes can match their intended purposes. Offers tips such as buying only composite-material buckets and wringers, choosing cleaning machines with good maintenance track records, and buying automatic scrubbers that can operate in both large and…

  8. Statistical analysis of environmental monitoring data: does a worst case time for monitoring clean rooms exist?

    PubMed

    Cundell, A M; Bean, R; Massimore, L; Maier, C

    1998-01-01

    To determine the relationship between the sampling time of the environmental monitoring, i.e., viable counts, in aseptic filling areas and the microbial count and frequency of alerts for air, surface and personnel microbial monitoring, statistical analyses were conducted on 1) the frequency of alerts versus the time of day for routine environmental sampling conducted in calendar year 1994, and 2) environmental monitoring data collected at 30-minute intervals during routine aseptic filling operations over two separate days in four different clean rooms with multiple shifts and equipment set-ups at a parenteral manufacturing facility. Statistical analyses showed, except for one floor location that had significantly higher number of counts but no alert or action level samplings in the first two hours of operation, there was no relationship between the number of counts and the time of sampling. Further studies over a 30-day period at the floor location showed no relationship between time of sampling and microbial counts. The conclusion reached in the study was that there is no worst case time for environmental monitoring at that facility and that sampling any time during the aseptic filling operation will give a satisfactory measure of the microbial cleanliness in the clean room during the set-up and aseptic filling operation.

  9. Airborne exposures to monoethanolamine, glycol ethers, and benzyl alcohol during professional cleaning: a pilot study.

    PubMed

    Melchior Gerster, Fabian; Brenna Hopf, Nancy; Pierre Wild, Pascal; Vernez, David

    2014-08-01

    A growing body of epidemiologic evidence suggests an association between exposure to cleaning products and respiratory dysfunction. Due to the lack of quantitative assessments of respiratory exposures to airborne irritants and sensitizers among professional cleaners, the culpable substances have yet to be identified. Focusing on previously identified irritants, our aims were to determine (i) airborne concentrations of monoethanolamine (MEA), glycol ethers, and benzyl alcohol (BA) during different cleaning tasks performed by professional cleaning workers and assess their determinants; and (ii) air concentrations of formaldehyde, a known indoor air contaminant. Personal air samples were collected in 12 cleaning companies, and analyzed by conventional methods. Nearly all air concentrations [MEA (n = 68), glycol ethers (n = 79), BA (n = 15), and formaldehyde (n = 45)] were far below (<1/10) of the corresponding Swiss occupational exposure limits (OEL), except for ethylene glycol mono-n-butyl ether (EGBE). For butoxypropanol and BA, no OELs exist. Although only detected once, EGBE air concentrations (n = 4) were high (49.48-58.72mg m(-3)), and close to the Swiss OEL (49mg m(-3)). When substances were not noted as present in safety data sheets of cleaning products used but were measured, air concentrations showed no presence of MEA, while the glycol ethers were often present, and formaldehyde was universally detected. Exposure to MEA was affected by its amount used (P = 0.036), and spraying (P = 0.000) and exposure to butoxypropanol was affected by spraying (P = 0.007) and cross-ventilation (P = 0.000). Professional cleaners were found to be exposed to multiple airborne irritants at low concentrations, thus these substances should be considered in investigations of respiratory dysfunctions in the cleaning industry; especially in specialized cleaning tasks such as intensive floor cleaning. © The Author 2014. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  10. Hygienic measures during animal transport to abattoirs - a status quo analysis of the current cleaning and disinfection of animal transporters in Germany.

    PubMed

    Weber, Luisa; Meemken, Diana

    2018-01-01

    The process of cleaning and disinfection of animal transport vehicles after unloading animals at the abattoir is a critical control point regarding proper hygiene. It is an important step regarding the biosecurity. In the present study, a status quo analysis of the currently performed cleaning and disinfection measures of animal transport vehicles was carried out at the vehicle washing facilities of five different industrial abattoirs in Germany. For this purpose, a checklist was developed and validated to assess the washing procedure of transport vehicles in a standardised way. The evaluated phases of cleaning included the evaluation criteria "length of time per used floor", "visual cleaning success" and the "hygienic awareness of the driver". During disinfection, attention was paid to the internal and external surfaces of the transporter and to the methods used to disinfect them. In addition, the technical and structural equipment of the five different washing facilities were recorded using a questionnaire and compared to the legal regulations, respectively. At each location, approximately 150 vehicles of all delivery types (transport vehicles owned by the abattoir, external delivery companies and vehicles owned by the supplying farmers) were inspected so that in total a number of more than 750 vehicles were included in this study. The aim was to develop abattoir specific, as well as generally applicable intervention measures and to generate "standard-operation procedures" (SOP's) for the cleaning and disinfection of animal transporters. At two out of five locations vehicles have left the abattoir without cleaning and disinfection. In 31-97% of all vehicles, only a cleaning of the vehicle was carried out, a subsequent disinfection did not take place. A cleaning followed by disinfecting took place in only 3-59% of all vehicles. The results indicate a considerable need for improvement and standardisation in this relevant field of disease prevention.

  11. Resource requirements of inclusive urban development in India: insights from ten cities

    NASA Astrophysics Data System (ADS)

    Singh Nagpure, Ajay; Reiner, Mark; Ramaswami, Anu

    2018-02-01

    This paper develops a methodology to assess the resource requirements of inclusive urban development in India and compares those requirements to current community-wide material and energy flows. Methods include: (a) identifying minimum service level benchmarks for the provision of infrastructure services including housing, electricity and clean cooking fuels; (b) assessing the percentage of homes that lack access to infrastructure or that consume infrastructure services below the identified benchmarks; (c) quantifying the material requirements to provide basic infrastructure services using India-specific design data; and (d) computing material and energy requirements for inclusive development and comparing it with current community-wide material and energy flows. Applying the method to ten Indian cities, we find that: 1%-6% of households do not have electricity, 14%-71% use electricity below the benchmark of 25 kWh capita-month-1 4%-16% lack structurally sound housing; 50%-75% live in floor area less than the benchmark of 8.75 m2 floor area/capita; 10%-65% lack clean cooking fuel; and 6%-60% lack connection to a sewerage system. Across the ten cities examined, to provide basic electricity (25 kWh capita-month-1) to all will require an addition of only 1%-10% in current community-wide electricity use. To provide basic clean LPG fuel (1.2 kg capita-month-1) to all requires an increase of 5%-40% in current community-wide LPG use. Providing permanent shelter (implemented over a ten year period) to populations living in non-permanent housing in Delhi and Chandigarh would require a 6%-14% increase over current annual community-wide cement use. Conversely, to provide permanent housing to all people living in structurally unsound housing and those living in overcrowded housing (<5 m cap-2) would require 32%-115% of current community-wide cement flows. Except for the last scenario, these results suggest that social policies that seek to provide basic infrastructure provisioning for all residents would not dramatically increasing current community-wide resource flows.

  12. 27 CFR 555.215 - Housekeeping.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... EXPLOSIVES, DEPARTMENT OF JUSTICE EXPLOSIVES COMMERCE IN EXPLOSIVES Storage § 555.215 Housekeeping. Magazines... are to be regularly swept. Brooms and other utensils used in the cleaning and maintenance of magazines must have no spark-producing metal parts, and may be kept in magazines. Floors stained by leakage from...

  13. Effects of Prenatal Exposure to Phthalates

    ERIC Educational Resources Information Center

    Johnson, Laurie A.

    2012-01-01

    The purpose of this review of literature is to examine the association of phthalate exposure with development. Phthalates are chemical compounds used in poly-vinyl chloride, PVC; vinyl flooring, cosmetics, shampoo, air fresheners, soft plastic items, intravenous tubing, food packaging and wraps, textiles, paints, cleaning products and detergents.…

  14. On-farm comparisons of different cleaning protocols in broiler houses.

    PubMed

    Luyckx, K Y; Van Weyenberg, S; Dewulf, J; Herman, L; Zoons, J; Vervaet, E; Heyndrickx, M; De Reu, K

    2015-08-01

    The present study evaluated the effectiveness of 4 cleaning protocols designed to reduce the bacteriological infection pressure on broiler farms and prevent food-borne zoonoses. Additionally, difficult to clean locations and possible sources of infection were identified. Cleaning and disinfection rounds were evaluated in 12 broiler houses on 5 farms through microbiological analyses and adenosine triphosphate hygiene monitoring. Samples were taken at 3 different times: before cleaning, after cleaning, and after disinfection. At each sampling time, swabs were taken from various locations for enumeration of the total aerobic flora and Enterococcus species pluralis ( SPP:). In addition, before cleaning and after disinfection, testing for Escherichia coli and Salmonella was carried out. Finally, adenosine triphosphate swabs and agar contact plates for total aerobic flora counts were taken after cleaning and disinfection, respectively. Total aerobic flora and Enterococcus spp. counts on the swab samples showed that cleaning protocols which were preceded by an overnight soaking with water caused a higher bacterial reduction compared to protocols without a preceding soaking step. Moreover, soaking of broiler houses leads to less water consumption and reduced working time during high pressure cleaning. No differences were found between protocols using cold or warm water during cleaning. Drinking cups, drain holes, and floor cracks were identified as critical locations for cleaning and disinfection in broiler houses. © 2015 Poultry Science Association Inc.

  15. 5-Second Rule

    MedlinePlus

    ... the tools used to wash them (picture eating food off the mop in the cafeteria if you need a visual). Even with a brand-new mop or sponge, stubborn germs can still be on the floor after cleaning. Fast is better ... fast enough. Although a piece of food does pick up more bacteria the longer it's ...

  16. 75 FR 15655 - Requirements for Control Technology Determinations for Major Sources in Accordance With Clean Air...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-30

    ... and/or copolymer products. Brick and Structural Clay Products...... 327121 Brick and structural clay tile manufacturing facilities. Brick and Structural Clay Products; Clay 327122 Ceramic wall and floor... Structural Clay Products...... 327123 Other structural clay products manufacturing facilities. Clay Ceramics...

  17. The concentrations of phthalates in settled dust in Bulgarian homes in relation to building characteristic and cleaning habits in the family

    NASA Astrophysics Data System (ADS)

    Kolarik, Barbara; Bornehag, Carl-Gustaf; Naydenov, Kiril; Sundell, Jan; Stavova, Petra; Nielsen, Ole Faurskov

    Phthalate esters are chemical compounds with a broad range of applications. Recently, we have shown that significantly higher dust concentration of di(2-ethylhexyl) phthalate (DEHP) was found in Bulgarian homes of children with asthma or allergies compared to healthy children. The concentration of DEHP was found to be significantly associated with wheezing in the last 12 months as reported by parents. The objective of the current study was to examine the associations between concentrations of phthalates in settled dust collected in Bulgarian homes and building characteristics and cleaning habits. Dust samples from the child's bedroom were collected in 177 homes and analysed for the content of dimethyl phthalate (DMP), diethyl phthalate (DEP), di-n-butyl phthalate (DnBP), butyl benzyl phthalate (BBzP), di- n-octyl phthalate (DnOP) and DEHP. Information on building characteristics and family habits were collected from parental reports in questionnaires and from inspectors' observations in the homes. Significantly higher concentrations of BBzP, DEHP and DnOP in indoor dust were found in homes where polishing agents were used, compared to homes where such products were not used. The highest concentrations of DEHP, BBzP and DnOP were found in homes with the combination of a low frequency of dusting and the use of polish. There was no difference in phthalate concentrations between inspector-observed balatum flooring (PVC or linoleum) and wood flooring as well as between PVC, as determined by Raman spectra, and wood flooring. However, in a sub-group of homes with no use of polish, the concentration of DEHP was higher in homes with inspector-observed balatum compared with wood flooring but the difference was not significant may be due to a too small sample size.

  18. Rust Contamination from Water Leaks in the Cosmic Dust Lab and Lunar and Meteorite Thin Sections Labs at Johnson Space Center

    NASA Technical Reports Server (NTRS)

    Kent, J. J.; Berger, E. L.; Fries, M. D.; Bastien, R.; McCubbin, F. M.; Pace, L.; Righter, K.; Sutter, B.; Zeigler, R. A.; Zolensky, M.

    2017-01-01

    On the early morning of September 15th, 2016, on the first floor of Building 31 at NASA-Johnson Space Center, the hose from a water chiller ruptured and began spraying water onto the floor. The water had been circulating though old metal pipes, and the leaked water contained rust-colored particulates. The water flooded much of the western wing of the building's ground floor before the leak was stopped, and it left behind a residue of rust across the floor, most notably in the Apollo and Meteorite Thin Section Labs and Sample Preparation Lab. No samples were damaged in the event, and the affected facilities are in the process of remediation. At the beginning of 2016, a separate leak occurred in the Cosmic Dust Lab, located in the same building. In that lab, a water leak occurred at the bottom of the sink used to clean the lab's tools and containers with ultra-pure water. Over years of use, the ultra-pure water eroded the metal sink piping and leaked water onto the inside of the lab's flow bench. This water also left behind a film of rusty material. The material was cleaned up and the metal piping was replaced with PVC pipe and sealed with Teflon plumber's tape. Samples of the rust detritus were collected from both incidents. These samples were imaged and analyzed to determine their chemical and mineralogical compositions. The purpose of these analyses is to document the nature of the detritus for future reference in the unlikely event that these materials occur as contaminants in the Cosmic Dust samples or Apollo or Meteorite thin sections.

  19. Forced-air warming and ultra-clean ventilation do not mix: an investigation of theatre ventilation, patient warming and joint replacement infection in orthopaedics.

    PubMed

    McGovern, P D; Albrecht, M; Belani, K G; Nachtsheim, C; Partington, P F; Carluke, I; Reed, M R

    2011-11-01

    We investigated the capacity of patient warming devices to disrupt the ultra-clean airflow system. We compared the effects of two patient warming technologies, forced-air and conductive fabric, on operating theatre ventilation during simulated hip replacement and lumbar spinal procedures using a mannequin as a patient. Infection data were reviewed to determine whether joint infection rates were associated with the type of patient warming device that was used. Neutral-buoyancy detergent bubbles were released adjacent to the mannequin's head and at floor level to assess the movement of non-sterile air into the clean airflow over the surgical site. During simulated hip replacement, bubble counts over the surgical site were greater for forced-air than for conductive fabric warming when the anaesthesia/surgery drape was laid down (p = 0.010) and at half-height (p < 0.001). For lumbar surgery, forced-air warming generated convection currents that mobilised floor air into the surgical site area. Conductive fabric warming had no such effect. A significant increase in deep joint infection, as demonstrated by an elevated infection odds ratio (3.8, p = 0.024), was identified during a period when forced-air warming was used compared to a period when conductive fabric warming was used. Air-free warming is, therefore, recommended over forced-air warming for orthopaedic procedures.

  20. STS-30 Magellan spacecraft is unpacked at Kennedy Space Center (KSC) SAEF-2

    NASA Technical Reports Server (NTRS)

    1989-01-01

    At the Kennedy Space Center (KSC) inside the Space Assembly and Encapsulation Facility 2 (SAEF-2) (planetary checkout facility), the cover of the Payload Environmental Transportation System (PETS) is removed so that the Magellan spacecraft can be hoisted from the PETS trailer to the clean room floor. Clean-suited technicians guide the cover above plastic-wrapped spacecraft using rope. The spacecraft, destined for unprecedented studies of the Venusian topographic features, is to be deployed by the crew of NASA STS-30 mission in April 1989. View provided by KSC with alternate number KSC-88PC-1083.

  1. 77 FR 14691 - Approval and Promulgation of Air Quality Implementation Plans; Rhode Island; Reasonably Available...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-13

    .... Specifically, the requirement does not apply to cold cleaning machines: (1) Used in ``special and extreme... products; 2. Requirements for charcoal lighter materials, aerosol adhesives and floor wax strippers; 3...). This APC regulation applies to anyone that solicits the use of or applies asphalt for road paving...

  2. Removal of Perfluorocarboxylic Acids (PFCAs) from Carpets Treated with Stain-protection Products by Using Carpet Cleaning Machines

    EPA Science Inventory

    PFCAs are found in a variety of consumer products, including, but not limited to, treated clothing and textiles, floor care products, paper containers for food, and carpets. For example, carpet that has been treated with stain-protection, carpet-care solutions, either by the manu...

  3. Defense Integrated Materiel Management Manual for Consumable Items

    DTIC Science & Technology

    1992-01-01

    GSA 7830 Recreational and Gymnastic Equipment GSA A-1-14 DoD 4140.26-K 7910 Floor Polishers and Vacuum Cleaning Equipment GSA 7920 Brooms, Brushes, Mops... Artists ’ Brushes GSA 8030 Preservative and Sealing Compounds GSA 8040 Adhesives GSA 8105 Bags and Sacks GSA 8110 Drums and Cans DGSC 8115 Boxes, Cartons

  4. 10. VIEW OF LAMINARFLOW FILTER WALL NEAR SOUTH WALL OF ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. VIEW OF LAMINAR-FLOW FILTER WALL NEAR SOUTH WALL OF CLEAN ROOM (102). NOTE GROUNDING CABLES NEAR BASEBOARD IN LOWER RIGHT BACKGROUND. WHITE SQUARE IN FOREGROUND IS A FLOOR DRAIN COVERED WITH TAPE. - Vandenberg Air Force Base, Space Launch Complex 3, Vehicle Support Building, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  5. Quantifying tasks, ergonomic exposures and injury rates among school custodial workers.

    PubMed

    Village, J; Koehoorn, M; Hossain, S; Ostry, A

    2009-06-01

    A job exposure matrix of ergonomics risk factors was constructed for school custodial workers in one large school district in the province of British Columbia using 100 h of 1-min fixed-interval observations, participatory worker consensus on task durations and existing employment and school characteristic data. Significant differences in ergonomics risk factors were found by tasks and occupations. Cleaning and moving furniture, handling garbage, cleaning washrooms and cleaning floors were associated with the most physical risks and the exposure was often higher during the summer vs. the school year. Injury rates over a 4-year period showed the custodian injury rate was four times higher than the overall injury rate across all occupations in the school district. Injury rates were significantly higher in the school year compared with summer (12.2 vs. 7.0 per 100 full-time equivalents per year, p < 0.05). Custodial workers represent a considerable proportion of the labour force and have high injury rates, yet ergonomic studies are disproportionately few. Previous studies that quantified risk factors in custodial workers tended to focus on a few tasks or specific risk factors. This study, using participatory ergonomics and observational methods, systematically quantifies the broad range of musculoskeletal risk factors across multiple tasks performed by custodial workers in schools, adding considerably to the methodological literature.

  6. Gait of dairy cows on floors with different slipperiness.

    PubMed

    Telezhenko, E; Magnusson, M; Bergsten, C

    2017-08-01

    This study assessed the slip resistance of different types of solid flooring in cattle housing using a range of technical tests and gait analysis. Dynamic and static coefficient of friction, skid resistance, and abrasiveness were tested on concrete flooring with a smooth finish, a grooved pattern, or a tamped pattern, acid-resistant mastic asphalt, soft rubber mats, and a worn slatted concrete floor. Coefficients of friction and skid resistance were tested under clean and slurry-soiled conditions. Linear kinematic variables were assessed in 40 cows with trackway measurements after the cows passed over the floors in a straight walk. All gait variables were assessed as deviations from those obtained on the slatted concrete floor, which was used as a baseline. The coefficient of friction tests divided the floors into 3 categories: concrete flooring, which had a low coefficient of friction (0.29-0.41); mastic asphalt flooring, which had medium values (0.38-0.45); and rubber mats, which had high values (0.49-0.57). The highest abrasion (g/10 m) was on the asphalt flooring (4.48), and the concrete flooring with a tamped pattern had significantly higher abrasiveness (2.77) than the other concrete floors (1.26-1.60). Lowest values on the skid-resistance tests (dry/wet) were for smooth concrete (79/35) and mastic asphalt (65/47), especially with a slurry layer on the surface. Gait analysis mainly differentiated floors with higher friction and abrasion by longer strides and better tracking. Step asymmetry was lower on floors with high skid-resistance values. The most secure cow gait, in almost every aspect, was observed on soft rubber mats. Relationships between gait variables and physical floor characteristics ranged from average to weak (partial correlations 0.54-0.16). Thus, none of the physical characteristics alone was informative enough to characterize slip resistance. With reference to gait analysis, the abrasiveness of the hard surfaces was more informative than the coefficient of friction, but the effect of pattern was better detected by skid-resistance measurements. Consequently, several physical characteristics are needed to objectively describe the slip resistance of cattle floors. Soft rubber mats gave better tracking than hard, solid floors, even with a grooved surface or a tamped pattern. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  7. Monitoring minimization of grade B environments based on risk assessment using three-dimensional airflow measurements and computer simulation.

    PubMed

    Katayama, Hirohito; Higo, Takashi; Tokunaga, Yuji; Katoh, Shigeo; Hiyama, Yukio; Morikawa, Kaoru

    2008-01-01

    A practical, risk-based monitoring approach using the combined data collected from actual experiments and computer simulations was developed for the qualification of an EU GMP Annex 1 Grade B, ISO Class 7 area. This approach can locate and minimize the representative number of sampling points used for microbial contamination risk assessment. We conducted a case study on an aseptic clean room, newly constructed and specifically designed for the use of a restricted access barrier system (RABS). Hotspots were located using three-dimensional airflow analysis based on a previously published empirical measurement method, the three-dimensional airflow analysis. Local mean age of air (LMAA) values were calculated based on computer simulations. Comparable results were found using actual measurements and simulations, demonstrating the potential usefulness of such tools in estimating contamination risks based on the airflow characteristics of a clean room. Intensive microbial monitoring and particle monitoring at the Grade B environmental qualification stage, as well as three-dimensional airflow analysis, were also conducted to reveal contamination hotspots. We found representative hotspots were located at perforated panels covering the air exhausts where the major piston airflows collect in the Grade B room, as well as at any locations within the room that were identified as having stagnant air. However, we also found that the floor surface air around the exit airway of the RABS EU GMP Annex 1 Grade A, ISO Class 5 area was always remarkably clean, possibly due to the immediate sweep of the piston airflow, which prevents dispersed human microbes from falling in a Stokes-type manner on settling plates placed on the floor around the Grade A exit airway. In addition, this airflow is expected to be clean with a significantly low LMAA. Based on these observed results, we propose a simplified daily monitoring program to monitor microbial contamination in Grade B environments. To locate hotspots we propose using a combination of computer simulation, actual airflow measurements, and intensive environmental monitoring at the qualification stage. Thereafter, instead of particle or microbial air monitoring, we recommend the use of microbial surface monitoring at the main air exhaust. These measures would be sufficient to assure the efficiency of the monitoring program, as well as to minimize the number of surface sampling points used in environments surrounding a RABS.

  8. Cleaning and disinfection programs against Campylobacter jejuni for broiler chickens: productive performance, microbiological assessment and characterization1

    PubMed Central

    Deliberali Lelis, Karoline; Granghelli, Carlos Alexandre; Carão de Pinho, Agatha Cristina; Ribeiro Almeida Queiroz, Sabrina; Fernandes, Andrezza Maria; Moro de Souza, Ricardo Luiz; Gaglianone Moro, Maria Estela; de Andrade Bordin, Roberto; de Albuquerque, Ricardo

    2017-01-01

    Abstract Detailed cleaning and disinfection programs aims to reduce infection pressure from microorganisms from one flock to the next. However, studies evaluating the benefits to poultry performance, the sanitary status of the facilities, and the sanitary quality of the meat are rarely found. Thus, this study was designed to evaluate 2 cleaning and disinfecting programs regarding their influence on productive performance, elimination of Campylobacter, and characterization of Campylobacter jejuni strains when applied to broiler chickens’ facilities. Two subsequent flocks with 960 birds each were distributed into 32 pens containing 30 birds each. In the first, the whole flock was inoculated with a known strain of Campylobacter jejuni in order to contaminate the environment. In the second flock, performance and microbiological evaluations were done, characterizing an observational study between 2 cleaning and disinfection programs, regular and proposed. The regular program consisted of sweeping facilities, washing equipment and environment with water and neutral detergent. The proposed cleaning program consisted of dry and wet cleaning, application of 2 detergents (one acid and one basic) and 2 disinfectants (250 g/L glutaraldehyde and 185 g/L formaldehyde at 0.5% and 210 g/L para-chloro-meta-cresol at 4%). Total microorganism count in the environment and Campylobacter spp. identification were done for the microbiological assessment of the environment and carcasses. The positive samples were submitted to molecular identification of Campylobacter spp. and posterior genetic sequencing of the species identified as Campylobacter jejuni. The birds housed in the facilities and submitted to the proposed treatment had better performance when compared to the ones in the regular treatment, most likely because there was a smaller total microorganism count on the floor, walls, feeders and drinkers. The proposed program also resulted in a reduction of Campylobacter spp. on floors, drinkers and birds. Moreover, it was possible to identify 6 different Campylobacter jejuni strains in the facilities. The proposed treatment resulted in a positive influence on the birds’ performance and reduction of environment contamination for broiler chickens. PMID:28854757

  9. Cleaning and disinfection programs against Campylobacter jejuni for broiler chickens: productive performance, microbiological assessment and characterization.

    PubMed

    Castro Burbarelli, Maria Fernanda de; do Valle Polycarpo, Gustavo; Deliberali Lelis, Karoline; Granghelli, Carlos Alexandre; Carão de Pinho, Agatha Cristina; Ribeiro Almeida Queiroz, Sabrina; Fernandes, Andrezza Maria; Moro de Souza, Ricardo Luiz; Gaglianone Moro, Maria Estela; de Andrade Bordin, Roberto; de Albuquerque, Ricardo

    2017-09-01

    Detailed cleaning and disinfection programs aims to reduce infection pressure from microorganisms from one flock to the next. However, studies evaluating the benefits to poultry performance, the sanitary status of the facilities, and the sanitary quality of the meat are rarely found. Thus, this study was designed to evaluate 2 cleaning and disinfecting programs regarding their influence on productive performance, elimination of Campylobacter, and characterization of Campylobacter jejuni strains when applied to broiler chickens' facilities. Two subsequent flocks with 960 birds each were distributed into 32 pens containing 30 birds each. In the first, the whole flock was inoculated with a known strain of Campylobacter jejuni in order to contaminate the environment. In the second flock, performance and microbiological evaluations were done, characterizing an observational study between 2 cleaning and disinfection programs, regular and proposed. The regular program consisted of sweeping facilities, washing equipment and environment with water and neutral detergent. The proposed cleaning program consisted of dry and wet cleaning, application of 2 detergents (one acid and one basic) and 2 disinfectants (250 g/L glutaraldehyde and 185 g/L formaldehyde at 0.5% and 210 g/L para-chloro-meta-cresol at 4%). Total microorganism count in the environment and Campylobacter spp. identification were done for the microbiological assessment of the environment and carcasses. The positive samples were submitted to molecular identification of Campylobacter spp. and posterior genetic sequencing of the species identified as Campylobacter jejuni. The birds housed in the facilities and submitted to the proposed treatment had better performance when compared to the ones in the regular treatment, most likely because there was a smaller total microorganism count on the floor, walls, feeders and drinkers. The proposed program also resulted in a reduction of Campylobacter spp. on floors, drinkers and birds. Moreover, it was possible to identify 6 different Campylobacter jejuni strains in the facilities. The proposed treatment resulted in a positive influence on the birds' performance and reduction of environment contamination for broiler chickens. © The Author 2017. Published by Oxford University Press on behalf of Poultry Science Association.

  10. A Pilot Study of the Effectiveness of Indoor Plants for Removal of Volatile Organic Compounds in Indoor Air in a Seven-Story Office Building

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Apte, Michael G.; Apte, Joshua S.

    2010-04-27

    The Paharpur Business Centre and Software Technology Incubator Park (PBC) is a 7 story, 50,400 ft{sup 2} office building located near Nehru Place in New Delhi India. The occupancy of the building at full normal operations is about 500 people. The building management philosophy embodies innovation in energy efficiency while providing full service and a comfortable, safe, healthy environment to the occupants. Provision of excellent Indoor Air Quality (IAQ) is an expressed goal of the facility, and the management has gone to great lengths to achieve it. This is particularly challenging in New Delhi, where ambient urban pollution levels rankmore » among the worst on the planet. The approach to provide good IAQ in the building includes a range of technical elements: air washing and filtration of ventilation intake air from rooftop air handler, the use of an enclosed rooftop greenhouse with a high density of potted plants as a bio-filtration system, dedicated secondary HVAC/air handling units on each floor with re-circulating high efficiency filtration and UVC treatment of the heat exchanger coils, additional potted plants for bio-filtration on each floor, and a final exhaust via the restrooms located at each floor. The conditioned building exhaust air is passed through an energy recovery wheel and chemisorbent cartridge, transferring some heat to the incoming air to increase the HVAC energy efficiency. The management uses 'green' cleaning products exclusively in the building. Flooring is a combination of stone, tile and 'zero VOC' carpeting. Wood trim and finish appears to be primarily of solid sawn materials, with very little evidence of composite wood products. Furniture is likewise in large proportion constructed from solid wood materials. The overall impression is that of a very clean and well-kept facility. Surfaces are polished to a high sheen, probably with wax products. There was an odor of urinal cake in the restrooms. Smoking is not allowed in the building. The plants used in the rooftop greenhouse and on the floors were made up of a number of species selected for the following functions: daytime metabolic carbon dioxide (CO{sub 2}) absorption, nighttime metabolic CO{sub 2} absorption, and volatile organic compound (VOC) and inorganic gas absorption/removal for air cleaning. The building contains a reported 910 indoor plants. Daytime metabolic species reported by the PBC include Areca Palm, Oxycardium, Rubber Plant, and Ficus alii totaling 188 plants (21%). The single nighttime metabolic species is the Sansevieria with a total of 28 plants (3%). The 'air cleaning' plant species reported by the PBC include the Money Plant, Aglaonema, Dracaena Warneckii, Bamboo Palm, and Raphis Palm with a total of 694 plants (76%). The plants in the greenhouse (Areca Palm, Rubber Plant, Ficus alii, Bamboo Palm, and Raphis Palm) numbering 161 (18%) of those in the building are grown hydroponically, with the room air blown by fan across the plant root zones. The plants on the building floors are grown in pots and are located on floors 1-6. We conducted a one-day monitoring session in the PBC on January 1, 2010. The date of the study was based on availability of the measurement equipment that the researchers had shipped from Lawrence Berkeley National Lab in the U.S.A. The study date was not optimal because a large proportion of the regular building occupants were not present being New Year's Day. An estimated 40 people were present in the building all day during January 1. This being said, the building systems were in normal operations, including the air handlers and other HVAC components. The study was focused primarily on measurements in the Greenhouse and 3rd and 5th floor environments as well as rooftop outdoors. Measurements included a set of volatile organic compounds (VOCs) and aldehydes, with a more limited set of observations of indoor and outdoor particulate and carbon dioxide concentrations. Continuous measurements of Temperature (T) and relative humidity (RH) were made selected indoor and outdoor locations.« less

  11. KSC-04pd1722

    NASA Image and Video Library

    2004-09-08

    KENNEDY SPACE CENTER, FLA. - KSC employees clean up inside the second floor of the Thermal Protection System Facility damaged by Hurricane Frances. The storm's path over Florida took it through Cape Canaveral and KSC property during Labor Day weekend. Located in Launch Complex 39, the facility is used to manufacture both internal and external insulation products for the Space Shuttle orbiters.

  12. 7 CFR 56.76 - Minimum facility and operating requirements for shell egg grading and packing plants.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... or rodents. (3) Buildings shall be of sound construction so as to prevent, insofar as practicable... cleaned at the end of each operating day. (5) The floors, walls, ceilings, partitions, and other parts of... reflection of light that interfere with, or prohibit the accurate quality determination of eggs in the...

  13. 7 CFR 56.76 - Minimum facility and operating requirements for shell egg grading and packing plants.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... or rodents. (3) Buildings shall be of sound construction so as to prevent, insofar as practicable... cleaned at the end of each operating day. (5) The floors, walls, ceilings, partitions, and other parts of... reflection of light that interfere with, or prohibit the accurate quality determination of eggs in the...

  14. 7 CFR 56.76 - Minimum facility and operating requirements for shell egg grading and packing plants.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... or rodents. (3) Buildings shall be of sound construction so as to prevent, insofar as practicable... cleaned at the end of each operating day. (5) The floors, walls, ceilings, partitions, and other parts of... reflection of light that interfere with, or prohibit the accurate quality determination of eggs in the...

  15. 7 CFR 56.76 - Minimum facility and operating requirements for shell egg grading and packing plants.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... or rodents. (3) Buildings shall be of sound construction so as to prevent, insofar as practicable... cleaned at the end of each operating day. (5) The floors, walls, ceilings, partitions, and other parts of... reflection of light that interfere with, or prohibit the accurate quality determination of eggs in the...

  16. 7 CFR 56.76 - Minimum facility and operating requirements for shell egg grading and packing plants.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... or rodents. (3) Buildings shall be of sound construction so as to prevent, insofar as practicable... cleaned at the end of each operating day. (5) The floors, walls, ceilings, partitions, and other parts of... reflection of light that interfere with, or prohibit the accurate quality determination of eggs in the...

  17. KSC-04pd1723

    NASA Image and Video Library

    2004-09-08

    KENNEDY SPACE CENTER, FLA. - KSC employees clean up inside the second floor of the Thermal Protection System Facility damaged by Hurricane Frances. The storm's path over Florida took it through Cape Canaveral and KSC property during Labor Day weekend. Located in Launch Complex 39, the facility is used to manufacture both internal and external insulation products for the Space Shuttle orbiters.

  18. KSC-04pd1724

    NASA Image and Video Library

    2004-09-08

    KENNEDY SPACE CENTER, FLA. - KSC employees clean up inside the second floor of the Thermal Protection System Facility damaged by Hurricane Frances. The storm's path over Florida took it through Cape Canaveral and KSC property during Labor Day weekend. Located in Launch Complex 39, the facility is used to manufacture both internal and external insulation products for the Space Shuttle orbiters.

  19. DWPF Melt Cell Crawler

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ward, C.R.

    2003-04-08

    On December 2, 2002, Remote and Specialty Equipment Systems (RSES) of the Savannah River Technology Center (SRTC) was requested to build a remotely operated crawler to assist in cleaning the Defense Waste Processing Facility (DWPF) melt cell floor of glass, tools, and other debris. The crawler was to assist a grapple and vacuum system in cleaning the cell. The crawler was designed to push glass and debris into piles so that the grapple could pick up the material and place it in waste bins. The crawler was also designed to maneuver the end of the vacuum hose, if needed. Inmore » addition, the crawler was designed to clean the area beneath the cell worktable that was inaccessible to the grapple and vacuum system. Originally, the system was to be ready for deployment by December 17. The date was moved up to December 12 to better utilize the available time for clean up. The crawler was designed and built in 10 days and completed cleaning the melt cell in 8 days. Due to initial problems with the grapple and vacuum system, the crawler completed essentially all of the cleanup tasks by itself. The crawler also cleaned an area on the west side of the cell that was not initially slated for cleaning.« less

  20. How Clean Are Hotel Rooms? Part I: Visual Observations vs. Microbiological Contamination.

    PubMed

    Almanza, Barbara A; Kirsch, Katie; Kline, Sheryl Fried; Sirsat, Sujata; Stroia, Olivia; Choi, Jin Kyung; Neal, Jay

    2015-01-01

    Current evidence of hotel room cleanliness is based on observation rather than empirically based microbial assessment. The purpose of the study described here was to determine if observation provides an accurate indicator of cleanliness. Results demonstrated that visual assessment did not accurately predict microbial contamination. Although testing standards have not yet been established for hotel rooms and will be evaluated in Part II of the authors' study, potential microbial hazards included the sponge and mop (housekeeping cart), toilet, bathroom floor, bathroom sink, and light switch. Hotel managers should increase cleaning in key areas to reduce guest exposure to harmful bacteria.

  1. Stress Tolerance of Methylobacterium Biofilms in Bathrooms

    PubMed Central

    Yano, Takehisa; Kubota, Hiromi; Hanai, Junya; Hitomi, Jun; Tokuda, Hajime

    2013-01-01

    A comprehensive survey of microbial flora within pink biofilms in bathrooms was performed. Pink biofilms develop relatively rapidly in bathrooms, can be difficult to remove, and are quick to recur. Bacterium-sized cells were found to be predominant in 42 pink biofilms in Japan using a scanning electron microscope. Methylobacterium strains were detected from all samples in bathrooms by an isolation method. To explain this predominance, 14 biofilm samples were analyzed by fluorescence in situ hybridization. Methylobacterium was indicated to be the major genus in all biofilms. The isolated Methylobacterium survived after contact with 1.0% cleaning agents, including benzalkonium chloride for 24 h. Their tolerance did not differ under biofilm-like conditions on fiber reinforced plastics (FRP), a general material of bath tubs, floors, and walls. Also, the strains exhibited higher tolerance to desiccation than other isolated species on FRP. Some Methylobacterium survived and exhibited potential to grow after four weeks of desiccation without any nutrients. These specific characteristics could be a cause of their predominance in bathrooms, an environment with rapid flowing water, drying, low nutrients, and occasional exposure to cleaning agents. PMID:23207727

  2. Forest water contamination

    Treesearch

    Roger M. Rowell

    2006-01-01

    Forests play a key role in cleaning water. Precipitation is “'filtered” through the tree canopy and filtered again throuph the organic matter on the forest floor. The water then seeps into the subsurface to replenish the ground water. Approximately 80% of the freshwater in the United States originates in the 650 million acres (265 million hectares) of forest that...

  3. Assessment of self-help methods to reduce potential exposure to radiological contamination after a large-scale radiological release.

    PubMed

    Snyder, Emily; Drake, John; Cardarelli, John; Hall, Kathy; Szabo, Jeff; Demmer, Rick; Lindberg, Michael; Riggs, Karen; James, Ryan

    2014-09-01

    After the release of radioactive materials from a large radiological dispersal device (e.g., dirty bomb), improvised nuclear detonation, or nuclear power plant accident, up to hundreds of square miles may be contaminated. A portion of this area will be evacuated; however, people living in the portion that is not evacuated yet is still contaminated with low-levels of radioactive contamination will be asking for ways they can reduce their exposure. Whether cleaning activities can significantly reduce exposure is not fully understood. In this effort, the ability of cleaning activities to remove cesium (137Cs) was studied. The removal efficacy of cleaning with a commercial product, Simple Green®, was compared to cleaning with water for hard surfaces typically seen in residences. The removal efficacy of laundering fabric material surfaces was also determined for a range of conditions (e.g., fabric material type, wash temperature). During these studies, assessments of the implications of these activities (e.g., cross-contamination, resulting waste streams) were also completed. Simple Green and water were effective for removing 137Cs from plastic laminate and vinyl flooring (93.4-96.8%) but were not effective for removing 137Cs from painted wallboard and wood (7.3-68.1%). It was also determined that there was no significant difference between the two cleaners on all of the surfaces, except plastic laminate, for which Simple Green was slightly more effective. Laundering was effective for removing 137Cs contamination from polyester and cotton swatches and cotton comforters (up to 96.8% in the single swatch testing).

  4. Nondestructive structural evaluation of wood floor systems with a vibration technique.

    Treesearch

    Xiping Wang; Robert J. Ross; Lawrence Andrew Soltis

    2002-01-01

    The objective of this study was to determine if transverse vibration methods could be used to effectively assess the structural integrity of wood floors as component systems. A total of 10 wood floor systems, including 3 laboratory-built floor sections and 7 in-place floors in historic buildings, were tested. A forced vibration method was applied to the floor systems...

  5. Does disinfection of environmental surfaces influence nosocomial infection rates? A systematic review.

    PubMed

    Dettenkofer, Markus; Wenzler, Sibylle; Amthor, Susanne; Antes, Gerd; Motschall, Edith; Daschner, Franz D

    2004-04-01

    To review the evidence on the effects of disinfection of environmental surfaces in hospitals (as compared with cleaning without use of disinfectants) on the occurrence of nosocomial infections. Systematic review of experimental and nonexperimental intervention studies dealing with environmental disinfection or cleaning in different health care settings. A total of 236 scientific articles were identified. None described a meta-analysis, systematic review, or randomized controlled trial. Only 4 articles described completed cohort studies matching the inclusion criteria. None of these studies showed lower infection rates associated with routine disinfection of surfaces (mainly floors) versus cleaning with detergent only. Disinfectants may pose a danger to staff, patients, and the environment and require special safety precautions. However, targeted disinfection of certain environmental surfaces is in certain instances an established component of hospital infection control. Given the complex, multifactorial nature of nosocomial infections, well-designed studies that systematically investigate the role of surface disinfection are required.

  6. Ethanol-based cleanser versus isopropyl alcohol to decontaminate stethoscopes.

    PubMed

    Lecat, Paul; Cropp, Elliott; McCord, Gary; Haller, Nairmeen Awad

    2009-04-01

    Approximately 1 in 20 hospital admissions is complicated by a health care-associated infection. Stethoscopes may play a role in spreading nosocomial infections. The objective of this study was to determine the effectiveness of an ethanol-based cleanser (EBC) compared with isopropyl alcohol pads in reducing bacterial contamination of stethoscope diaphragms. Stethoscopes were cultured from medical professionals on 4 medical floors before and after cleaning with either EBC or isopropyl alcohol pads. The numbers of colony-forming units (cfu) grown were compared between the 2 cleaners and to baseline values. A total of 99 stethoscopes were cultured (49 EBC; 50 isopropyl alcohol), and all were positive for growth. After cleaning, 28.28% of the stethoscopes were growth-free (12 EBC; 16 isopropyl alcohol). Cleaning with EBC and isopropyl alcohol pads significantly reduced the cfu counts (by 92.8% and 92.5%, respectively), but neither was found to be statistically superior (F = 1.22; P = .2721). Cleaning a stethoscope diaphragm using either EBC or isopropyl alcohol led to a significant reduction in bacterial growth in culture. As an extension of the hand, a stethoscope should be cleaned with the same frequency as the hands. The simultaneous cleaning of hands and stethoscope may further increase compliance with current standards.

  7. An Abiotic Glass-Bead Collector Exhibiting Active Transport

    NASA Astrophysics Data System (ADS)

    Goto, Youhei; Kanda, Masato; Yamamoto, Daigo; Shioi, Akihisa

    2015-09-01

    Animals relocate objects as needed by active motion. Active transport is ubiquitous in living organisms but has been difficult to realize in abiotic systems. Here we show that a self-propelled droplet can gather scattered beads toward one place on a floor and sweep it clean. This is a biomimetic active transport with loadings and unloadings, because the transport was performed by a carrier and the motion of the carrier was maintained by the energy of the chemical reaction. The oil droplet produced fluctuation of the local number density of the beads on the floor, followed by its autocatalytic growth. This mechanism may inspire the technologies based on active transport wherein chemical and physical substances migrate as in living organisms.

  8. 76 FR 19989 - New York State Prohibition of Discharges of Vessel Sewage; Receipt of Petition and Tentative...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-11

    ... readily available for pumpout while the ferries are docked in Bridgeport. SUNY Maritime College's large...: Notice is hereby given that, pursuant to Clean Water Act, Section 312(f)(3) (33 U.S.C. 1322(f)(3)), the... and Hand Delivery/Courier: Moses Chang, U.S. EPA Region 2, 290 Broadway, 24th Floor, New York, NY...

  9. Variation in susceptibility of laboratory and field strains of three stored-grain insect species to beta-cyfluthrin and chlorpyrifos-methyl plus deltamethrin applied to concrete surfaces

    USDA-ARS?s Scientific Manuscript database

    The efficacy of beta-cyfluthrin and chlorpyrifos-methyl plus deltamethrin applied to clean, concrete floors of empty bins prior to grain storage against field strains of stored-grain insects is unknown. We exposed adults of 16 strains of the red flour beetle, Tribolium castaneum (Herbst); 8 strains ...

  10. [Phantoms for the collection of genital secretions in stallions].

    PubMed

    Klug, E; Brinkhoff, D; Flüge, A; Scherbarth, R; Essich, G; Kienzler, M

    1977-10-05

    Practical experiences of the phantom method for collection of genital secretions from stallions are reported. Taking a phantom used in the Richard-Götze-Haus Tierärztliche Hochschule Hannover as a prototype two further models slightly modified have been constructed, baring a flat hollow in the right side of the caudal phantom body for manual inserting of the Artificial Vagina. These three models fulfill four important conditions for routine use: (1) sufficient sexual attractivity for the stallions; 80-85% successful collections of presecretions out of a total of 1050 using the dummy and 70% successful semen collections from more than 240 in total; (2) solid and resistant construction; (3) easy cleaning and desinfection of the surface of the phantom to get representative samples; (4) firm installation on a hygienic floor.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haywood, F.F.; Dickson, H.W.; Cottrell, W.D.

    A radiological survey was made of the former Bridgeport Brass Special Metals Extrusion Plant in Adrian, Michigan, now owned by General Motors Corporation. This plant was operated to extrude uranium metal which was used in the fabrication of reactor fuel for the Hanford, Washington, and Savannah River, South Carolina, plants. Activities at the Adrian plant included preparation of material for extrusion, abrasive sawing, storing, packaging, and shipping. When the original contract was concluded, most of the equipment was dismantled and salvaged. The current property owner cleaned much of the building and conducted his own radiological survey. The results of themore » General Motors survey indicated that the area originally involved in the uranium handling and processing operation was within tolerances under the provision of guidelines applicable at the time the facility was decommissioned. A comprehensive survey was conducted in that area by a team of health physicists from the Oak Ridge National Laboratory (ORNL). The results of this survey tend to confirm the findings of the General Motors report, except that some floor areas were contaminated in excess of applicable guidelines and some off-gas ducts which had been used in the cutting area were found to be contaminated with uranium. These ducts were removed, the floor areas were cleaned, and a subsequent resurvey of the plant was made. An additional survey of a portion of the facility was conducted by ORNL health physicists after learning that service pits had existed beneath the extrusion units. Sometime after extrusion operations ceased, these pits were filled with sand and covered over at the existing floor level with concrete. Results of this survey revealed concentrations of /sup 238/U up to 21,000 pCi/g of residue, scale, and other miscellaneous materials collected from the bottom of service pits, service manholes, and holding tanks.« less

  12. Floor Identification with Commercial Smartphones in Wifi-Based Indoor Localization System

    NASA Astrophysics Data System (ADS)

    Ai, H. J.; Liu, M. Y.; Shi, Y. M.; Zhao, J. Q.

    2016-06-01

    In this paper, we utilize novel sensors built-in commercial smart devices to propose a schema which can identify floors with high accuracy and efficiency. This schema can be divided into two modules: floor identifying and floor change detection. Floor identifying module starts at initial phase of positioning, and responsible for determining which floor the positioning start. We have estimated two methods to identify initial floor based on K-Nearest Neighbors (KNN) and BP Neural Network, respectively. In order to improve performance of KNN algorithm, we proposed a novel method based on weighting signal strength, which can identify floors robust and quickly. Floor change detection module turns on after entering into continues positioning procedure. In this module, sensors (such as accelerometer and barometer) of smart devices are used to determine whether the user is going up and down stairs or taking an elevator. This method has fused different kinds of sensor data and can adapt various motion pattern of users. We conduct our experiment with mobile client on Android Phone (Nexus 5) at a four-floors building with an open area between the second and third floor. The results demonstrate that our scheme can achieve an accuracy of 99% to identify floor and 97% to detecting floor changes as a whole.

  13. THERMAL EVALUATION OF CONTAMINATED LIQUID ONTO CELL FLOORS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NOEMAIL), J

    2009-05-04

    For the Salt Disposition Integration Project (SDIP), postulated events in the new Salt Waste Processing Facility (SWPF) can result in spilling liquids that contain Cs-137 and organics onto cell floors. The parameters of concern are the maximum temperature of the fluid following a spill and the time required for the maximum fluid temperature to be reached. Control volume models of the various process cells have been developed using standard conduction and natural convection relationships. The calculations are performed using the Mathcad modeling software. The results are being used in Consolidated Hazards Analysis Planning (CHAP) to determine the controls that maymore » be needed to mitigate the potential impact of liquids containing Cs-137 and flammable organics that spill onto cell floors. Model development techniques and the ease of making model changes within the Mathcad environment are discussed. The results indicate that certain fluid spills result in overheating of the fluid, but the times to reach steady-state are several hundred hours. The long times allow time for spill clean up without the use of expensive mitigation controls.« less

  14. Effects of floor heating and litter quality on the development and severity of foot pad dermatitis in young turkeys.

    PubMed

    Abd El-Wahab, A; Beineke, A; Beyerbach, M; Visscher, C F; Kamphues, J

    2011-09-01

    Actions concerning animal health in turkey production are coming more and more to the fore. Litter quality has a great impact on the bird's health and welfare. This study aimed at evaluating the effects of using floor heating, different litter materials, and exposure to litter with a "critical moisture content" of 35% for 16 or 24 hr/day on the severity of foot pad dermatitis (FPD), a widespread disease in fattening turkeys. Four groups of 2-wk-old female turkeys, with 20 birds in each, were reared during 3 wk. All turkeys were fed a commercial pellet diet ad libitum. The first two groups were kept on wood shavings (35% moisture) without and with floor heating. The other two groups were housed on lignocellulose (Soft Cell) of 35% moisture without and with floor heating. In each group, half of the birds were housed for 8 hr/day in adjacent separate boxes where the litter was kept clean and dry throughout the experimental period. Foot pads were assessed weekly for external and at day 35 for histopathologic scoring (scores: 0 = healthy; 7 = ulcer). At day 14 each bird had normal and healthy foot pads. The results indicate that using floor heating resulted in significantly lower FPD scores (0.8 +/- 0.2) compared to groups without floor heating (2.0 +/- 0.8). Using lignocellulose as a litter material resulted in significantly lower histopathologic FPD scores (1.4 +/- 0.7) compared with wood shavings (1.7 +/- 0.8). In all birds housed on dry litter for 8 hr/day, significantly lower FPD scores were found compared to birds housed on wet litter for 24 hr. In conclusion, using floor heating, even with wet litter (35% moisture), independent of the litter type, resulted in reduced severity of FPD compared to those birds housed in pens without using floor heating. Additionally, using lignocellulose as a litter material resulted in lower FPD compared with wood shavings. Keeping litter dry and "warm" could be achieved by using floor heating, which is considered a practical step to enhance animal health and welfare.

  15. Pyrosequencing-Derived Bacterial, Archaeal, and Fungal Diversity of Spacecraft Hardware Destined for Mars

    PubMed Central

    Vaishampayan, Parag; Nilsson, Henrik R.; Torok, Tamas; Venkateswaran, Kasthuri

    2012-01-01

    Spacecraft hardware and assembly cleanroom surfaces (233 m2 in total) were sampled, total genomic DNA was extracted, hypervariable regions of the 16S rRNA gene (bacteria and archaea) and ribosomal internal transcribed spacer (ITS) region (fungi) were subjected to 454 tag-encoded pyrosequencing PCR amplification, and 203,852 resulting high-quality sequences were analyzed. Bioinformatic analyses revealed correlations between operational taxonomic unit (OTU) abundance and certain sample characteristics, such as source (cleanroom floor, ground support equipment [GSE], or spacecraft hardware), cleaning regimen applied, and location about the facility or spacecraft. National Aeronautics and Space Administration (NASA) cleanroom floor and GSE surfaces gave rise to a larger number of diverse bacterial communities (619 OTU; 20 m2) than colocated spacecraft hardware (187 OTU; 162 m2). In contrast to the results of bacterial pyrosequencing, where at least some sequences were generated from each of the 31 sample sets examined, only 13 and 18 of these sample sets gave rise to archaeal and fungal sequences, respectively. As was the case for bacteria, the abundance of fungal OTU in the GSE surface samples dramatically diminished (9× less) once cleaning protocols had been applied. The presence of OTU representative of actinobacteria, deinococci, acidobacteria, firmicutes, and proteobacteria on spacecraft surfaces suggests that certain bacterial lineages persist even following rigorous quality control and cleaning practices. The majority of bacterial OTU observed as being recurrent belonged to actinobacteria and alphaproteobacteria, supporting the hypothesis that the measures of cleanliness exerted in spacecraft assembly cleanrooms (SAC) inadvertently select for the organisms which are the most fit to survive long journeys in space. PMID:22729532

  16. Prime Contract Awards by Service Category and Federal Supply Classification, Fiscal Years 1980, 1981, 1982, 1983.

    DTIC Science & Technology

    1983-01-01

    GYMNASTIC EQUIPMENT 1,773 2 e94 3,938 2 49P TOTAL 4,552 5,038 8 292 5 278 79 CLEANING EQUIPMENT AND SUPPLIES 7910 FLOOR POLISHERS AND VACUUM CLEANERS 1,188...8020 PAINT AND ARTISTS BRUSHES 10 67 11 0 8030 PRESERVATIVE AND SEALING COMPOUNDS 851 8.340 2.169 1.183 8040 ADHESIVES 272 447 839 278 TOTAL 7.288 18,248

  17. Blast Loading and Response of Underground Concrete-Arch Protective Structures

    DTIC Science & Technology

    1959-06-05

    to approximate the load due to pasive earth pressure developed in the region of outward deflection of the arch. This Is assumed as a radial sinus...to represent a specimen from the wall matter , and preserve the gradation. Sufficient live reinforcement, the floor-slab reinforcement, and the storage...chemicals, or other foreign materials shall cleaned of latance, foreign matter , and loose parti- not be mixed with the concrete to prevent freezing. cles

  18. Using Multiple Barometers to Detect the Floor Location of Smart Phones with Built-in Barometric Sensors for Indoor Positioning

    PubMed Central

    Xia, Hao; Wang, Xiaogang; Qiao, Yanyou; Jian, Jun; Chang, Yuanfei

    2015-01-01

    Following the popularity of smart phones and the development of mobile Internet, the demands for accurate indoor positioning have grown rapidly in recent years. Previous indoor positioning methods focused on plane locations on a floor and did not provide accurate floor positioning. In this paper, we propose a method that uses multiple barometers as references for the floor positioning of smart phones with built-in barometric sensors. Some related studies used barometric formula to investigate the altitude of mobile devices and compared the altitude with the height of the floors in a building to obtain the floor number. These studies assume that the accurate height of each floor is known, which is not always the case. They also did not consider the difference in the barometric-pressure pattern at different floors, which may lead to errors in the altitude computation. Our method does not require knowledge of the accurate heights of buildings and stories. It is robust and less sensitive to factors such as temperature and humidity and considers the difference in the barometric-pressure change trends at different floors. We performed a series of experiments to validate the effectiveness of this method. The results are encouraging. PMID:25835189

  19. Generation of airborne Listeria innocua from model floor drains.

    PubMed

    Berrang, Mark E; Frank, Joseph F

    2012-07-01

    Listeria monocytogenes can colonize floor drains in poultry processing and further processing facilities, remaining present even after cleaning and disinfection. Therefore, during wash down, workers exercise caution to avoid spraying hoses directly into drains in an effort to prevent the escape and transfer of drain microflora to food contact surfaces. The objective of this study was to examine the extent to which an inadvertent water spray into a colonized floor drain can cause the spread of airborne Listeria. Listeria innocua was used to inoculate a polyvinyl chloride model floor drain, resulting in approximately 10(8) cells per ml of phosphate-buffered saline and 10(4) attached cells per square centimeter of inner surface. Each model drain was subjected to a 2-s spray of tap water at 68.9 kPa from a distance of 1 m. Drains were sprayed while filled and again after emptying. Airborne cells were collected by using sedimentation plates containing Listeria selective agar which were placed on the floor and walls of a contained room at incremental horizontal and vertical distances of 0.6, 1.2, 2.4, or 4.0 m from the drain. Sedimentation plates were exposed for 10 min. A mechanical sampler was used to also collect air by impaction on the surface of Listeria selective agar to determine the number of cells per liter of air. The experiment was conducted in triplicate rooms for each of four replications. L. innocua was detected on sedimentation plates on the floor as far as 4.0 m from the drain and on walls as high as 2.4 m above the floor and 4 m from the drain. A 2-s spray with a water hose into a contaminated drain can cause airborne spread of Listeria, resulting in the potential for cross-contamination of food contact surfaces, equipment, and exposed product.

  20. [Myelofibrosis in a benzene-exposed cleaning worker].

    PubMed

    Bausà, Roser; Navarro, Lydia; Cortès-Franch, Imma

    Long-term exposure to benzene has been associated with several blood malignancies, including aplastic anemia, myeloproliferative neoplasms, and different leukemias. We present a case of primary myelofibrosis in a 59-year-old woman who worked as a cleaner at a car dealership and automobile mechanic shop. For 25 years, she used gasoline as a degreaser and solvent to clean engine parts, floors and work desks on a daily basis. She was referred by her primary care provider to the Occupational Health Unit of Barcelona to assess whether her illness was work-related. Review of her job history and working conditions revealed chronic exposure to benzene in the absence of adequate preventive measures. An association between benzene exposure and myeloproliferative disease was established, suspicious for an occupational disease. Copyright belongs to the Societat Catalana de Salut Laboral.

  1. Comparison of changes in the mobility of the pelvic floor muscle on during the abdominal drawing-in maneuver, maximal expiration, and pelvic floor muscle maximal contraction

    PubMed Central

    Jung, Halim; Jung, Sangwoo; Joo, Sunghee; Song, Changho

    2016-01-01

    [Purpose] The purpose of this study was to compare changes in the mobility of the pelvic floor muscle during the abdominal drawing-in maneuver, maximal expiration, and pelvic floor muscle maximal contraction. [Subjects] Thirty healthy adults participated in this study (15 men and 15 women). [Methods] All participants performed a bridge exercise and abdominal curl-up during the abdominal drawing-in maneuver, maximal expiration, and pelvic floor muscle maximal contraction. Pelvic floor mobility was evaluated as the distance from the bladder base using ultrasound. [Results] According to exercise method, bridge exercise and abdominal curl-ups led to significantly different pelvic floor mobility. The pelvic floor muscle was elevated during the abdominal drawing-in maneuver and descended during maximal expiration. Finally, pelvic floor muscle mobility was greater during abdominal curl-up than during the bridge exercise. [Conclusion] According to these results, the abdominal drawing-in maneuver induced pelvic floor muscle contraction, and pelvic floor muscle contraction was greater during the abdominal curl-up than during the bridge exercise. PMID:27065532

  2. Comparison of changes in the mobility of the pelvic floor muscle on during the abdominal drawing-in maneuver, maximal expiration, and pelvic floor muscle maximal contraction.

    PubMed

    Jung, Halim; Jung, Sangwoo; Joo, Sunghee; Song, Changho

    2016-01-01

    [Purpose] The purpose of this study was to compare changes in the mobility of the pelvic floor muscle during the abdominal drawing-in maneuver, maximal expiration, and pelvic floor muscle maximal contraction. [Subjects] Thirty healthy adults participated in this study (15 men and 15 women). [Methods] All participants performed a bridge exercise and abdominal curl-up during the abdominal drawing-in maneuver, maximal expiration, and pelvic floor muscle maximal contraction. Pelvic floor mobility was evaluated as the distance from the bladder base using ultrasound. [Results] According to exercise method, bridge exercise and abdominal curl-ups led to significantly different pelvic floor mobility. The pelvic floor muscle was elevated during the abdominal drawing-in maneuver and descended during maximal expiration. Finally, pelvic floor muscle mobility was greater during abdominal curl-up than during the bridge exercise. [Conclusion] According to these results, the abdominal drawing-in maneuver induced pelvic floor muscle contraction, and pelvic floor muscle contraction was greater during the abdominal curl-up than during the bridge exercise.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    none, none; Tuchman, Nancy

    The U.S. Department of Energy awarded Loyola University Chicago and the Institute of Environmental Sustainability (IES) $486,000.00 for the proposal entitled “Chicago clean air, clean water project: Environmental monitoring for a healthy, sustainable urban future.” The project supported the purchase of analytical instruments for the development of an environmental analytical laboratory. The analytical laboratory is designed to support the testing of field water and soil samples for nutrients, industrial pollutants, heavy metals, and agricultural toxins, with special emphasis on testing Chicago regional soils and water affected by coal-based industry. Since the award was made in 2010, the IES has beenmore » launched (fall 2013), and the IES acquired a new state-of-the-art research and education facility on Loyola University Chicago’s Lakeshore campus. Two labs were included in the research and education facility. The second floor lab is the Ecology Laboratory where lab experiments and analyses are conducted on soil, plant, and water samples. The third floor lab is the Environmental Toxicology Lab where lab experiments on environmental toxins are conducted, as well as analytical tests conducted on water, soil, and plants. On the south end of the Environmental Toxicology Lab is the analytical instrumentation collection purchased from the present DOE grant, which is overseen by a full time Analytical Chemist (hired January 2016), who maintains the instruments, conducts analyses on samples, and helps to train faculty and undergraduate and graduate student researchers.« less

  4. Effects of training to implement new working methods to reduce knee strain in floor layers. A two-year follow-up.

    PubMed

    Jensen, L K; Friche, C

    2008-01-01

    Follow-up study after two years to measure the effects of an implementation strategy consisting of information, education and training in the use of new tools and working-methods for the purpose of reducing knee strain and knee complaints in floor layers. Training of floor layers (n = 292) in using new working methods was evaluated by questionnaires during the courses. Two years later, this follow-up included questionnaires for the course participants (n = 216) and a control group of floor layers (not trained on courses) (n = 454). Two years after training, 38% used the new working methods weekly or daily compared to 37% three months after the courses, and 10% before. Among controls, only 16% had used the new working methods weekly or daily. The risk of knee complaints >30 days (OR 2.46, 95% CI 1.03 to 5.83) or locking of the knees (OR 2.89, 95% CI 1.11 to 7.5) was more than double among floor layers who had used the new working-methods for less than one year compared to those who had used them more. The results were adjusted for age, body mass index, and stress. The reduction in more severe knee complaints was greatest if floor layers started to use the new working methods before they developed knee problems. Other musculoskeletal complaints did not increase. This indicates that, within a two-year perspective, the implementation strategy to introduce new working methods in the floor laying trade has been effective; the number of floor layers using the new working-methods has increased, and severe knee problems have reduced.

  5. A Novel Method of Orbital Floor Reconstruction Using Virtual Planning, 3-Dimensional Printing, and Autologous Bone.

    PubMed

    Vehmeijer, Maarten; van Eijnatten, Maureen; Liberton, Niels; Wolff, Jan

    2016-08-01

    Fractures of the orbital floor are often a result of traffic accidents or interpersonal violence. To date, numerous materials and methods have been used to reconstruct the orbital floor. However, simple and cost-effective 3-dimensional (3D) printing technologies for the treatment of orbital floor fractures are still sought. This study describes a simple, precise, cost-effective method of treating orbital fractures using 3D printing technologies in combination with autologous bone. Enophthalmos and diplopia developed in a 64-year-old female patient with an orbital floor fracture. A virtual 3D model of the fracture site was generated from computed tomography images of the patient. The fracture was virtually closed using spline interpolation. Furthermore, a virtual individualized mold of the defect site was created, which was manufactured using an inkjet printer. The tangible mold was subsequently used during surgery to sculpture an individualized autologous orbital floor implant. Virtual reconstruction of the orbital floor and the resulting mold enhanced the overall accuracy and efficiency of the surgical procedure. The sculptured autologous orbital floor implant showed an excellent fit in vivo. The combination of virtual planning and 3D printing offers an accurate and cost-effective treatment method for orbital floor fractures. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  6. Dairy cow preferences for soft or hard flooring when standing or walking.

    PubMed

    Telezhenko, E; Lidfors, L; Bergsten, C

    2007-08-01

    Concrete is the most commonly used alley flooring in confined dairy herds because of its qualities of construction and ease of cleaning. Nevertheless, the hardness, abrasiveness, and slipperiness of concrete floors have adverse effects on animal well-being and health, and yielding rubber flooring is becoming popular as a way of improving the flooring conditions on walkways. The aim of this study was to investigate preferences of dairy cows for rubber compared with concrete flooring under the conditions of a commercial dairy farm. The study was conducted in an organic dairy herd with free-stall housing. Floor preference was tested on groups of standing cows in a 120-m2 holding pen before milking, and 1 yr later on a 12- x 3-m walkway. The holding pen and the walkway were divided lengthwise into 2 identical sections. Two types of solid rubber mats (soft and extra soft) were tested against solid concrete in the holding pen. Slatted and solid rubber mats were tested against slatted concrete in the walkway. Each floor type was tested over 4 d on the left side and 4 d on the right side of the holding pen and the walkway, respectively. Concrete flooring on both sides of the sections was tested as a control before the testing of different section materials. All observations of the distribution of cows in the sections were made from video recordings captured in association with the afternoon milking. The number of cows on each section was recorded approximately every 7 min in the holding pen, and continuously on the walkway. A significantly higher proportion of cows stood on the side with the soft and extra soft rubber mats (65.1 +/- 2.7 and 69.3 +/- 2.6%, respectively, mean +/- SEM) compared with the control distribution when only the solid concrete was available (50.9 +/- 3.9%). A significantly higher proportion of nonlame cows walked exclusively on the side with the slatted (64.5 +/- 5.4%, d 4) or solid rubber mats (68.2 +/- 5.1%, d 4) compared with controls (28.9 +/- 4.3%). Lame cows within a group of walking cows did not show a higher preference for soft flooring as distinct as nonlame cows (52.7 +/- 6.9 and 59.4 +/- 6.2% for the solid and slatted rubber mats, respectively, at d 4 vs. 40.3 +/- 6.2% for control), presumably because of competition with other, higher ranked cows. It was concluded that the majority of cows preferred to walk and stand on soft rubber rather than on concrete flooring.

  7. Cleaning-resistant Cupriavidus and Ralstonia bacteria contaminating spacecrafts and the ultra clean rooms they are assembled in.

    NASA Astrophysics Data System (ADS)

    Leys, N.; Dams, A.; Bossus, A.; Provoost, A.; Venkateswaran, K.; Mergeay, M.

    Background Planetary Protection is preventing microbial contamination of both the target planet and the Earth when sending spacecrafts on interplanetary space mission It is important to preserve the natural conditions of other planets and to not bring with robots earthly microbes forward contamination when looking for spores of extra terrestrial life Spacecrafts and the ultra clean rooms they are assembled in are routinely monitored for microbial contamination It was shown that the floor air and surfaces of such spacecraft assembly rooms often contain Cupriavidu s and Ralstonia bacteria These bacteria not only contaminated the clean rooms but have also been found prior-to-flight on surfaces of space robots such as the Mars Odyssey Orbiter La Duc et al 2003 and even in-flight in ISS cooling water and Shuttle drinking water unpublished Aim In this study several Cupriavidus and Ralstonia strains isolated from space craft assembling rooms and spacecrafts were characterized and analysed in detail Results The analysis showed that all the Cupriavidus and Ralstonia clean-room isolates are able to use a wide variety of substrates as carbon sources including ethanol and acetone In addition they all have accumulated moderate resistances to an extraordinary collection of physical and chemical antimicrobial agents Some of the test strains were able to form biofilms on plastic and metal materials used for space robots a nutritional and

  8. Formaldehyde and TVOC emission behavior of laminate flooring by structure of laminate flooring and heating condition.

    PubMed

    An, Jae-Yoon; Kim, Sumin; Kim, Hyun-Joong

    2011-03-15

    Formaldehyde was measured with a desiccator, a 20 L chamber and the FLEC method. The formaldehyde emission rate from laminate was the highest at 32 °C using the desiccator, which then decreased with time. The formaldehyde emission using the 20 L small chamber and FLEC showed a similar tendency. There was a strong correlation between the formaldehyde and total volatile organic compounds (TVOCs) with both types of floorings using the two different methods. The formaldehyde emission rate and TVOC results were higher when tested using the FLEC method than with the 20 L small chamber method. The emission rate was affected by the joint edge length in laminate flooring. Toluene, ethylbenzene and xylene were the main VOCs emitted from laminate flooring, and there were more unidentified VOCs emitted than identified VOCs. The samples heated with a floor heating system emitted more formaldehyde than those heated using an air circulation system due to the temperature difference between the bottom panel and flooring. The TVOC emission level of the samples was higher when an air circulation system was used than when a floor heating system was used due to the high ventilation rate. Copyright © 2010 Elsevier B.V. All rights reserved.

  9. [Quantitative analysis of factors to influence the environment of the clean room and clean bench during preparation of intravenous hyperalimentation (IVH) admixtures].

    PubMed

    Hotoda, S; Aoyama, T; Sato, A; Yamamura, Y; Nakajima, K; Nakamura, K; Sato, H; Iga, T

    1999-12-01

    We quantitatively studied factors influencing the environment cleanliness for intravenous hyperalimentation (IVH) admixing. The environment cleanliness was evaluated by measuring the counts of particles (> 0.5 micron) and bacteria floating in 1 ft3 of the air inside the clean room (23.6 m3) and in the clean bench built in the department of pharmacy, The University of Tokyo Hospital in 1998. The number of particles at the center of the clean room during IVH admixing by 4 pharmacists was higher than that at the medicine passing area (150 +/- 50/ft3 vs. 260 +/- 60/ft3; mean +/- S.D., n = 12). The cleanliness inside the clean room was improved as the measurement point became higher from the floor (600 +/- 180/ft3, 150 +/- 50/ft3, and 35 +/- 15/ft3 at 50, 100, and 150 cm height, respectively) and the number of persons working inside the room decreased. The changes in the counts of floating bacteria were similar to that of floating particles under the same conditions. In addition the effect of disinfection on the counts of bacteria was clearly observed. When the cleanliness of the room became lower by turning off the air conditioning, the particle counts inside the clean bench became lower along with the distance from the front glass becoming deeper (i.e., 1400 +/- 550/ft3, 140 +/- 70/ft3, and 40 +/- 30/ft3 at 0, 5, and 15 cm, respectively). From these lines of evidence, the following items were suggested in order to maintain the environment cleanliness for IVH admixing. First, the number of persons residing in the clean room should be kept to be minimum. Second, the clean bench should be set up in the center of the clean room. Finally IVH admixing operation should be performed at more than 15 cm depth inside the front glass surface of the clean bench. Moreover, the effect of mopping-up of the clean room with 0.1% benzethonium chloride clearly demonstrated the importance of disinfection on a routine basis.

  10. Mycological flora of the Hammams, traditional Turkish bath.

    PubMed

    Goksugur, Nadir; Karabay, Oguz; Kocoglu, Esra

    2006-09-01

    Traditional Turkish baths, Hammams, occupy a prominent place in public health in history and at present. It is well-known that baths are major sources of fungal skin infections, but according to our knowledge fungal flora of Turkish Hammams was not defined yet. In Bolu, Turkey, two Hammams were open to public and for detecting fungal flora, we collected 209 samples from different part of floors, tools and screened for the fungal pathogens. From floors of the dressing rooms, Trichophyton rubrum and Candida albicans; from slippers T. rubrum, T. mentagrophytes, Epidermophyton floccosum, Candida albicans and C. tropicalis were isolated. While we could not isolate any dermatophyte species and yeasts from the vicinity of the bath windows and walls of baths, Aspergillus spp. and Penicillium spp. were isolated from the same locations. Samples taken from marble floors of baths, central massage platforms (hottest part of the Hammam) and towels did not show any fungal growth. This report reveals that components of the Turkish Hammams have low risk for fungal contamination as a result of frequent cleaning and environmental high temperature. But shared tools like slippers were found to be an important source of fungal contamination.

  11. Mapping the Sea Floor of the Historic Area Remediation Site (HARS) Offshore of New York City

    USGS Publications Warehouse

    Butman, Bradford

    2002-01-01

    The area offshore of New York City has been used for the disposal of dredged material for over a century. The area has also been used for the disposal of other materials such as acid waste, industrial waste, municipal sewage sludge, cellar dirt, and wood. Between 1976 and 1995, the New York Bight Dredged Material Disposal Site, also known as the Mud Dump Site (MDS), received on average about 6 million cubic yards of dredged material annually. In September 1997 the MDS was closed as a disposal site, and it and the surrounding area were designated as the Historic Area Remediation Site (HARS). The sea floor of the HARS, approximately 9 square nautical miles in area, currently is being remediated by placing a minimum 1-m-thick cap of clean dredged material on top of the surficial sediments that are contaminated from previous disposal of dredged and other materials. The U.S. Geological Survey (USGS) is working cooperatively with the U.S. Army Corps of Engineers (USACE) to map the sea floor geology of the HARS and changes in the characteristics of the surficial sediments over time.

  12. Nondestructive methods for the structural evaluation of wood floor systems in historic buildings : preliminary results : [abstract

    Treesearch

    Zhiyong Cai; Michael O. Hunt; Robert J. Ross; Lawrence A. Soltis

    1999-01-01

    To date, there is no standard method for evaluating the structural integrity of wood floor systems using nondestructive techniques. Current methods of examination and assessment are often subjective and therefore tend to yield imprecise or variable results. For this reason, estimates of allowable wood floor loads are often conservative. The assignment of conservatively...

  13. Demonstration and Validation of a High-Performance Floor-Sealant System to Reduce Concrete Degradation

    DTIC Science & Technology

    2015-05-01

    1 Recycled Antifreeze 01-197-7692 MIL-PRF-10924H GAA Grease 01-102-9455 MIL-PRF-46176B Brake Fluid 00-252-6383 MIL-PRF-5606H Hydraulic Fluid H515...contaminated clothing , clean thoroughly before reuse. Inhalation: Move to fresh air. If not breathing, give rescue breathing. I f breathing is...material to absorb the spill, use plastic shovel to pick up absorbent for disposal Spills and Leaks: Dispose in accordance to local, state or federal

  14. Measuring the Effectiveness of the Apparel Advanced Manufacturing Demonstration Program. Appendices B-E

    DTIC Science & Technology

    1990-12-30

    DAVID were around cleaning up or counting A inventory. One whole floor of CHATHAM modem, automated equipment was __ draped with protective coverings...58 5060 N. Pire Street 11201 Armour Drive hazietor DA i8201 - ;Z Paso 7X 799:5 Mr. Sylvano aonarli Mr. Larry Price -resident Executive Vice...GA880493 Ncrti Ina.ustrl.a ark 440 Armour -:ace. . Rioley TN 38063 - Atlanta GA 30324 r. Riclarc Rin. Mr. Samuel S. Scnowls (y Er, ineerno ana.er

  15. Frequently observed risk factors for fall-related injuries and effective preventive interventions: a multihospital survey of nurses' perceptions.

    PubMed

    Tzeng, Huey-Ming; Yin, Chang-Yi

    2013-01-01

    There is an urgent need to prioritize the risk factors for injurious falls and effective interventions in nursing practice. Registered nurses perceived that the most frequently observed risk factors were confusion, gait problems, Alzheimer disease, disorientation, and inability to follow safety instructions. The most effective interventions were keeping hospital bed brakes locked, keeping floor surfaces clean/dry, using appropriate footwear for patients, maintaining a call light within reach, and reducing tripping hazards.

  16. EPHECT III: Health risk assessment of exposure to household consumer products.

    PubMed

    Trantallidi, M; Dimitroulopoulou, C; Wolkoff, P; Kephalopoulos, S; Carrer, P

    2015-12-01

    In the framework of the EU EPHECT project (Emissions, Exposure Patterns and Health Effects of Consumer Products in the EU), irritative and respiratory effects were assessed in relation to acute (30-min) and long-term (24-h) inhalation exposure to key and emerging indoor air pollutants emitted during household use of selected consumer products. A detailed Health Risk Assessment (HRA) was performed for five selected pollutants of respiratory health relevance, namely acrolein, formaldehyde, naphthalene, d-limonene and α-pinene. For each pollutant, the Critical Exposure Limit (CEL) was compared to indoor air concentrations and exposure estimates for the use of 15 selected consumer products by two population groups (housekeepers and retired people) in the four geographical regions of Europe (North, West, South, East), which were derived previously based on microenvironmental modelling. For the present HRA, health-based CELs were derived for certain compounds in case indoor air quality guidelines were not available by the World Health Organization for end-points relevant to the current study. For each pollutant, the highest indoor air concentrations in each microenvironment and exposure estimates across home microenvironments during the day were lower than the corresponding acute and long-term CELs. However, considerable contributions, especially to acute exposures, were obtained in some cases, such as formaldehyde emissions resulting from single product use of a floor cleaning agent (82% CEL), a candle (10% CEL) and an electric air freshener (17% CEL). Regarding multiple product use, the case of 30-min formaldehyde exposure reaching 34% CEL when eight product classes were used across home microenvironments, i.e. all-purpose/kitchen/floor cleaning agents, furniture/floor polish, combustible/electric air fresheners, and perfume, needs to be highlighted. Such estimated values should be evaluated with caution, as these may be attributed to the exposure scenarios specifically constructed for the present study, following a 'most-representative worst-case scenario' approach for exposure and health risk assessment. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. L. monocytogenes in a cheese processing facility: Learning from contamination scenarios over three years of sampling.

    PubMed

    Rückerl, I; Muhterem-Uyar, M; Muri-Klinger, S; Wagner, K-H; Wagner, M; Stessl, B

    2014-10-17

    The aim of this study was to analyze the changing patterns of Listeria monocytogenes contamination in a cheese processing facility manufacturing a wide range of ready-to-eat products. Characterization of L. monocytogenes isolates included genotyping by pulsed-field gel electrophoresis (PFGE) and multi-locus sequence typing (MLST). Disinfectant-susceptibility tests and the assessment of L. monocytogenes survival in fresh cheese were also conducted. During the sampling period between 2010 and 2013, a total of 1284 environmental samples were investigated. Overall occurrence rates of Listeria spp. and L. monocytogenes were 21.9% and 19.5%, respectively. Identical L. monocytogenes genotypes were found in the food processing environment (FPE), raw materials and in products. Interventions after the sampling events changed contamination scenarios substantially. The high diversity of globally, widely distributed L. monocytogenes genotypes was reduced by identifying the major sources of contamination. Although susceptible to a broad range of disinfectants and cleaners, one dominant L. monocytogenes sequence type (ST) 5 could not be eradicated from drains and floors. Significantly, intense humidity and steam could be observed in all rooms and water residues were visible on floors due to increased cleaning strategies. This could explain the high L. monocytogenes contamination of the FPE (drains, shoes and floors) throughout the study (15.8%). The outcome of a challenge experiment in fresh cheese showed that L. monocytogenes could survive after 14days of storage at insufficient cooling temperatures (8 and 16°C). All efforts to reduce L. monocytogenes environmental contamination eventually led to a transition from dynamic to stable contamination scenarios. Consequently, implementation of systematic environmental monitoring via in-house systems should either aim for total avoidance of FPE colonization, or emphasize a first reduction of L. monocytogenes to sites where contamination of the processed product is unlikely. Drying of surfaces after cleaning is highly recommended to facilitate the L. monocytogenes eradication. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Fundamental challenges to methane recovery from gas hydrates

    USGS Publications Warehouse

    Servio, P.; Eaton, M.W.; Mahajan, D.; Winters, W.J.

    2005-01-01

    The fundamental challenges, the location, magnitude, and feasibility of recovery, which must be addressed to recover methane from dispersed hydrate sources, are presented. To induce dissociation of gas hydrate prior to methane recovery, two potential methods are typically considered. Because thermal stimulation requires a large energy input, it is less economically feasible than depressurization. The new data will allow the study of the effect of pressure, temperature, diffusion, porosity, tortuosity, composition of gas and water, and porous media on gas-hydrate production. These data also will allow one to improve existing models related to the stability and dissociation of sea floor hydrates. The reproducible kinetic data from the planned runs together with sediment properties will aid in developing a process to economically recover methane from a potential untapped hydrate source. The availability of plentiful methane will allow economical and large-scale production of methane-derived clean fuels to help avert future energy crises.

  19. Experimental Verification of an Instrument to Test Flooring Materials

    NASA Astrophysics Data System (ADS)

    Philip, Rony; Löfgren, Hans, Dr

    2018-02-01

    The focus of this work is to validate the fluid model with different flooring materials and the measurements of an instrument to test flooring materials and its force attenuating capabilities using mathematical models to describe the signature and coefficients of the floor. The main contribution of the present work focus on the development of a mathematical fluid model for floors. The aim of the thesis was to analyze, compare different floor materials and to study the linear dynamics of falling impacts on floors. The impact of the hammer during a fall is captured by an accelerometer and response is collected using a picoscope. The collected data was analyzed using matlab least square method which is coded as per the fluid model. The finding from this thesis showed that the fluid model works with more elastic model but it doesn’t work for rigid materials like wood. The importance of parameters like velocity, mass, energy loss and other coefficients of floor which influences the model during the impact of falling on floors were identified and a standardized testing method was set.

  20. A dual-rating method for evaluating impact noise isolation of floor-ceiling assemblies.

    PubMed

    LoVerde, John J; Dong, D Wayland

    2017-01-01

    Impact Insulation Class (IIC), the single-number rating for evaluating the impact noise insulation of a floor-ceiling assembly, and the associated field testing ratings, are unsatisfactory because they do not have strong correlation with subjective reaction nor provide suitable detailed information for evaluation or design of floor-ceiling assemblies. Various proposals have been made for improving the method, but the data presented indicate that no single-number rating can adequately characterize the impact noise isolation of an assembly. For realistic impact noise sources and floor-ceiling assembly types, there are two frequency domains for impact noise, and the impact noise levels in the two domains can vary independently. Therefore, two ratings are required in order to satisfactorily evaluate the impact isolation provided by a floor-ceiling assembly. Two different ratings are introduced for measuring field impact isolation in the two frequency domains, using the existing impact source and measurement method. They are named low-frequency impact rating (LIR) and high-frequency impact rating (HIR). LIR and HIR are proposed to improve the current method for design and evaluation of floor-ceiling assemblies and also provide a better method for predicting subjective reaction.

  1. Endotoxin levels and contribution factors of endotoxins in resident, school, and office environments - A review

    NASA Astrophysics Data System (ADS)

    Salonen, Heidi; Duchaine, Caroline; Létourneau, Valérie; Mazaheri, Mandana; Laitinen, Sirpa; Clifford, Sam; Mikkola, Raimo; Lappalainen, Sanna; Reijula, Kari; Morawska, Lidia

    2016-10-01

    As endotoxin exposure has known effects on human health, it is important to know the generally existing levels of endotoxins as well as their contributing factors. This work reviews current knowledge on the endotoxin loads in settled floor dust, concentrations of endotoxins in indoor air, and different environmental factors potentially affecting endotoxin levels. The literature review consists of peer-reviewed manuscripts located using Google and PubMed, with search terms based on individual words and combinations. References from relevant articles have also been searched. Analysis of the data showed that in residential, school, and office environments, the mean endotoxin loads in settled floor dust varied between 660 and 107,000 EU/m2, 2180 and 48,000 EU/m2, and 2700 and 12,890 EU/m2, respectively. Correspondingly, the mean endotoxin concentrations in indoor air varied between 0.04 and 1610 EU/m3 in residences, and 0.07 and 9.30 EU/m3 in schools and offices. There is strong scientific evidence indicating that age of houses (or housing unit year category), cleaning, farm or rural living, flooring materials (the presence of carpets), number of occupants, the presence of dogs or cats indoors, and relative humidity affect endotoxin loads in settled floor dust. The presence of pets (especially dogs) was extremely strongly associated with endotoxin concentrations in indoor air. However, as reviewed articles show inconsistency, additional studies on these and other possible predicting factors are needed.

  2. Evaluation of the effects of footwear hygiene protocols on nonspecific bacterial contamination of floor surfaces in an equine hospital.

    PubMed

    Stockton, Kelly A; Morley, Paul S; Hyatt, Doreene R; Burgess, Brandy A; Patterson, Gage; Dunowska, Magda; Lee, David E

    2006-04-01

    To evaluate the effects of footwear hygiene protocols on bacterial contamination of floor surfaces in an equine hospital. Field trial. Footwear hygiene protocols evaluated included use of rubber overboots with footbaths and footmats containing a quaternary ammonium disinfectant, rubber overboots with footbaths and footmats containing a peroxygen disinfectant, and no restrictions on footwear type but mandatory use of footbaths and footmats containing a peroxygen disinfectant. Nonspecific aerobic bacterial counts were determined via 2 procedures for sample collection and bacterial enumeration (contact plates vs swabbing combined with use of spread plates), and the effects of each footwear hygiene protocol were compared. There were no consistent findings suggesting that any of the protocols were associated with differences in numbers of bacteria recovered from floor surfaces. Although there were detectable differences in numbers of bacteria recovered in association with different footwear hygiene protocols, differences in least square mean bacterial counts did not appear to be clinically relevant (ie, were < 1 log10). Although cleaning and disinfection of footwear are important aids in reducing the risk of nosocomial transmission of infectious agents in veterinary hospitals, the numbers of aerobic bacteria recovered from floor surfaces were not affected by use of rubber overboots or the types of disinfectant used in this study. Further study is warranted to evaluate the usefulness of footwear hygiene practices relative to their efficacy for reducing transmission of specific pathogens or decreasing nosocomial disease risk.

  3. Effects of two trimming methods of dairy cattle on concrete or rubber-covered slatted floors.

    PubMed

    Ouweltjes, W; Holzhauer, M; van der Tol, P P J; van der Werf, J

    2009-03-01

    This study monitored claw health, claw conformation, locomotion, activity, and step traits of cows from a single dairy herd that were trimmed according to the standard Dutch method or with an alternative "concave" trimming method. Half of the cows were kept in a stall section with concrete slatted floors in the alleys. The other cows were kept in a pen within the same housing with an identical concrete slatted floor in the alleys, but with a rubber top layer. All experimental cows were kept in the same environment for at least 3 mo before and after trimming. It was hypothesized that trimming for more-concave soles (i.e., with 3 to 5 mm of sole dug out under the claw bone) was preferred to the standard Dutch trimming with flat sole surfaces for cows kept in stalls with soft alley floors. None of the claw health or locomotion traits differed for the trimming methods. No interactions were found between flooring and trimming method. Floor effects were significant for several traits. Cows on the rubber-topped floors had significantly fewer sole hemorrhages (prevalence of 22 vs. 48% in mo 3) and larger claws (claw length 76.1 +/- 5.0 vs. 72.5 +/- 4.9 mm; heel height 49.3 +/- 6.3 vs. 46.0 +/- 6.4 mm; claw diagonal 129 +/- 6.4 vs. 125 +/- 6.9 mm), spent more time standing in the alleys (55.4 +/- 2.8 vs. 49.6 +/- 2.8%), and had higher activity (61.0 +/- 3.7 vs. 53.0 +/- 3.7 steps/h). This suggests greater claw comfort on rubber flooring compared with concrete flooring. Kinetic patterns during claw-floor contact while walking were similar for all treatments. During the double-support (stance) phase, claw-floor contact area increased to a maximum in the first 30% of double-support phase time, remained more or less stable until 80% of double-support phase time, and sharply decreased as the animal pushed off as shown by the change in center of pressure. A gradual change of center of pressure in the medial direction during double-support phase time was shown. The research hypothesis was rejected, but soft alley floors had subtle beneficial effects.

  4. Comparison of slime-producing coagulase-negative Staphylococcus colonization rates on vinyl and ceramic tile flooring materials.

    PubMed

    Yazgi, H; Uyanik, M H; Ayyildiz, A

    2009-01-01

    This study investigated the colonization of slime-producing coagulase-negative Staphylococcus (CoNS) in 80 patient wards in Turkey (40 vinyl and 40 ceramic tile floors). A total of 480 samples that included 557 CoNS isolates were obtained. Slime production was investigated with the Christensen method and methicillin-susceptibility was tested by the disk-diffusion method. There was a significant difference in the percentage of slime-producing CoNS isolates on vinyl (12.4%) versus ceramic tile flooring (4.4%). From vinyl flooring, the percentage of slime producing methicillin-resistant CoNS (MRCoNS) (8.9%) was significantly higher than for methicillin-sensitive CoNS (MSCoNS) (3.6%), whereas there was no difference from ceramic tile flooring (2.5% MRCoNS versus 1.8% MSCoNS). The most commonly isolated slime-producing CoNS species was S. epidermidis on both types of flooring. It is concluded that vinyl flooring seems to be a more suitable colonization surface for slime-producing CoNS than ceramic tile floors. Further studies are needed to investigate bacterial strains colonized on flooring materials, which are potential pathogens for nosocomial infections.

  5. Research progress of nano self - cleaning anti-fouling coatings

    NASA Astrophysics Data System (ADS)

    Liu, Y.; Zhao, Y. J.; Teng, J. L.; Wang, J. H.; Wu, L. S.; Zheng, Y. L.

    2018-01-01

    There are many methods of evaluating the performance of nano self-cleaning anti-fouling coatings, such as carbon blacking method, coating reflection coefficient method, glass microbead method, film method, contact angle and rolling angle method, organic degradation method, and the application of performance evaluation method in self-cleaning antifouling coating. For the more, the types of nano self-cleaning anti-fouling coatings based on aqueous media was described, such as photocatalytic self-cleaning coatings, silicone coatings, organic fluorine coatings, fluorosilicone coatings, fluorocarbon coatings, polysilazane self-cleaning coatings. The research and application of different kinds of nano self-cleaning antifouling coatings are anlysised, and the latest research results are summed.

  6. CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF DISLODGEABLE RESIDUES -- PUF ROLLER SAMPLES FOR PERSISTENT ORGANIC POLLUTANTS (SOP-2.18)

    EPA Science Inventory

    This SOP describes the method to collect transferable residues from indoor floor surfaces. The sampling procedures described are applicable to bare floors or covered floor surfaces, e.g., carpeting and vinyl flooring. The samples will be collected only in the day care centers o...

  7. Development and Testing of a Mobile Platform for Tank Remediation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nance, T.A.

    2001-01-16

    The Department of Energy (DOE) is committed to removing millions of gallons of high level radioactive waste from waste storage tanks at the Savannah River Site (SRS). SRS was the first site in the DOE complex to have emptied and closed high level waste tanks. Tank closure at the Site is now progressing to tanks containing waste composed of liquid and large deposits of solids, including a tank that has a potential ''heel''. A heel is a hardened mass of solid waste material spread across the tank bottom. Tank closure requires breaking up this heel and moving the material tomore » the intake of a pumping system for transfer from the tank. In the past, overhead spray systems have been used with some success at moving waste. But the limited number of risers restricts the coverage area of the overhead spray system. Therefore, a floor- level spray system will be used to separate manageable size chunks of the material from the heel. The chunks will be guided into the pump's intake to be remove from the tank. The floor-level spray system movement will be accomplished by using a mobile platform, a crawler, which provides transport to nearly every point on the tank floor. Transport of the spray system will allow the system to ''corral'' the waste away from the tank walls and control the movement of the material across the tank floor. Because the available access riser is small, and a wide crawler platform is required to support the spray system, the crawler's frame must fold to enter the tank. After entry into the tank, the crawler unfolds on the tank floor using the crawler drive tracks to expand the frame and position the mobile platform under the entry riser. The spray system will then be lowered separately through the entry riser and mated onto the crawler on the tank floor. The crawler and spray system are tethered and controlled remotely by personnel at the control station. Motorized cable reels will also be remotely controlled to pay out, retrieve, and manage the tethers as the mobile platform moves the spray system across the tank floor. Both the crawler and spray systems are designed to be retrievable. Development of the tank cleaning system was evaluated using a performance test program. The tests evaluated the spray system dynamics, the crawler's fit through the riser, the crawler landing in mocked up tank with simulant, the crawler's traction, and the crawler and spray system mating. Initial testing verified the crawler platform was compatible with the dynamics produced by the spray system. The riser fit test confirmed that a dedicated riser is required for deployment of the crawler and the spray system. The crawler traction test defined the capabilities of the crawler at different levels of simulant. Deployment testing through a mockup riser verified the basic system processes. Finally, testing of the complete system in a full-scale mockup with sludge simulant was performed to evaluate the tank cleaning ability of the crawler. This paper describes th e tank conditions, the tank closure process, the development of the crawler and spray system, and the testing program and results used to evaluate the mobile platform and spray system.« less

  8. A Monocular Vision Sensor-Based Obstacle Detection Algorithm for Autonomous Robots.

    PubMed

    Lee, Tae-Jae; Yi, Dong-Hoon; Cho, Dong-Il Dan

    2016-03-01

    This paper presents a monocular vision sensor-based obstacle detection algorithm for autonomous robots. Each individual image pixel at the bottom region of interest is labeled as belonging either to an obstacle or the floor. While conventional methods depend on point tracking for geometric cues for obstacle detection, the proposed algorithm uses the inverse perspective mapping (IPM) method. This method is much more advantageous when the camera is not high off the floor, which makes point tracking near the floor difficult. Markov random field-based obstacle segmentation is then performed using the IPM results and a floor appearance model. Next, the shortest distance between the robot and the obstacle is calculated. The algorithm is tested by applying it to 70 datasets, 20 of which include nonobstacle images where considerable changes in floor appearance occur. The obstacle segmentation accuracies and the distance estimation error are quantitatively analyzed. For obstacle datasets, the segmentation precision and the average distance estimation error of the proposed method are 81.4% and 1.6 cm, respectively, whereas those for a conventional method are 57.5% and 9.9 cm, respectively. For nonobstacle datasets, the proposed method gives 0.0% false positive rates, while the conventional method gives 17.6%.

  9. Robust Statistical Approaches for RSS-Based Floor Detection in Indoor Localization.

    PubMed

    Razavi, Alireza; Valkama, Mikko; Lohan, Elena Simona

    2016-05-31

    Floor detection for indoor 3D localization of mobile devices is currently an important challenge in the wireless world. Many approaches currently exist, but usually the robustness of such approaches is not addressed or investigated. The goal of this paper is to show how to robustify the floor estimation when probabilistic approaches with a low number of parameters are employed. Indeed, such an approach would allow a building-independent estimation and a lower computing power at the mobile side. Four robustified algorithms are to be presented: a robust weighted centroid localization method, a robust linear trilateration method, a robust nonlinear trilateration method, and a robust deconvolution method. The proposed approaches use the received signal strengths (RSS) measured by the Mobile Station (MS) from various heard WiFi access points (APs) and provide an estimate of the vertical position of the MS, which can be used for floor detection. We will show that robustification can indeed increase the performance of the RSS-based floor detection algorithms.

  10. NASA Agency Overview Briefing

    NASA Technical Reports Server (NTRS)

    2006-01-01

    The briefing opened with Dean Acosta (NASA Press Secretary) introducing Michael Griffin (NASA Administrator) and Bill Gerstenmaier (Associate Administrator for Space Operations). Bill Griffin stated that they would resume the Shuttle Fight to Return process, that the vehicle was remarkably clean and if the weather was good, the Shuttle would be ready to launch as scheduled. Bill Gerstenmaier stated that the preparations and processing of the vehicle went extremely well and they are looking forward to increasing the crew size to three. Then the floor was open to questions from the press.

  11. Ammonia emissions from air cleaners at pig farms in Denmark using a Picarro cavity ring-down spectrometer

    NASA Astrophysics Data System (ADS)

    Winkler, Renato; Adamsen, Anders Peter S.

    2017-04-01

    Ammonia emissions from agricultural activities such as, cattle, pig and poultry farms have become an ever more important topic both for scientists as well as for regulatory bodies due to the severe impacts of ammonia on human health and the environment. In the European Union, the agricultural sector accounts for most of the ammonia emissions, and therefore the EU authorities have put in place reduction targets for the member states. In Denmark, most pig farmers have to deploy one or more ammonia abatement technologies in order to fulfill the national regulation when building new pig houses. A promising ammonia abatement technology is partial floor ventilation and subsequent cleaning using one or two step chemical air cleaners. The cleaned air will have ammonia concentration is the sub-ppm level and with high humidity. Here we present method of monitoring NH3 emissions from air cleaners deployed on pig farms using the G2103 Picarro laser spectrometer. The Picarro G2103 NH3 analyzer is a high precision cavity ring-down spectrometer using a high finesse optical cavity and a near infra-red light laser light source with a very narrow light band. The latter eliminates cross-interferences from other gases present in livestock air. Picarro instruments are built for field measurements and have been widely used for atmospheric monitoring of greenhouse gases and of air pollutants such as NH3.

  12. Exploring physical exposures and identifying high-risk work tasks within the floor layer trade

    PubMed Central

    McGaha, Jamie; Miller, Kim; Descatha, Alexis; Welch, Laurie; Buchholz, Bryan; Evanoff, Bradley; Dale, Ann Marie

    2014-01-01

    Introduction Floor layers have high rates of musculoskeletal disorders yet few studies have examined their work exposures. This study used observational methods to describe physical exposures within floor laying tasks. Methods We analyzed 45 videos from 32 floor layers using Multimedia-Video Task Analysis software to determine the time in task, forces, postures, and repetitive hand movements for installation of four common flooring materials. We used the WISHA checklists to define exposure thresholds. Results Most workers (91%) met the caution threshold for one or more exposures. Workers showed high exposures in multiple body parts with variability in exposures across tasks and for different materials. Prolonged exposures were seen for kneeling, poor neck and low back postures, and intermittent but frequent hand grip forces. Conclusions Floor layers experience prolonged awkward postures and high force physical exposures in multiple body parts, which probably contribute to their high rates of musculoskeletal disorders. PMID:24274895

  13. Changes in Organic Matter And Nutrients in Forest Floor After Applying Several Reproductive Cutting Methods in Shortleaf Pine-Hardwood Stands

    Treesearch

    Hal O. Liechty; Michael G. Shelton

    2004-01-01

    Abstract - This study was initiated to determine the effects of various regeneration cutting methods on forest floor mass and nutrient content in shortleaf pine-hardwood communities in the Ouachita and Ozark National Forests. Clearcutting generally altered forest floor concentrations of N, P, and S as well as loss on ignition by increasing the amount...

  14. Assessment of the effect of pelvic floor exercises on pelvic floor muscle strength using ultrasonography in patients with urinary incontinence: a prospective randomized controlled trial

    PubMed Central

    Tosun, Ozge Celiker; Solmaz, Ulas; Ekin, Atalay; Tosun, Gokhan; Gezer, Cenk; Ergenoglu, Ahmet Mete; Yeniel, Ahmet Ozgur; Mat, Emre; Malkoc, Mehtap; Askar, Niyazi

    2016-01-01

    [Purpose] The aim of this study was to evaluate whether the effect of pelvic floor exercises on pelvic floor muscle strength could be detected via ultrasonography in patients with urinary incontinence. [Subjects and Methods] Of 282 incontinent patients, 116 participated in the study and were randomly divided into a pelvic floor muscle training (n=65) group or control group (n=51). The pelvic floor muscle training group was given pelvic floor exercise training for 12 weeks. Both groups were evaluated at the beginning of the study and after 12 weeks. Abdominal ultrasonography measurements in transverse and longitudinal planes, the PERFECT scheme, perineometric evaluation, the stop test, the stress test, and the pad test were used to assess pelvic floor muscle strength in all cases. [Results] After training, the PERFECT, perineometry and transabdominal ultrasonography measurements were found to be significantly improved, and the stop test and pad test results were significantly decreased in the pelvic floor muscle training group, whereas no difference was observed in the control group. There was a positive correlation between the PERFECT force measurement scale and ultrasonography force measurement scale before and after the intervention in the control and pelvic floor muscle training groups (r=0.632 and r=0.642, respectively). [Conclusion] Ultrasonography can be used as a noninvasive method to identify the change in pelvic floor muscle strength with exercise training. PMID:27065519

  15. Deflections of Uniformly Loaded Floors. A Beam-Spring Analog.

    DTIC Science & Technology

    1984-09-01

    joist floor systems have long been analyzed and Recently, the FEAFLO program was used to predict the designed by assuming that the joists act as...simple beams in behavior of floors constructed with joists whose properties carrying the design load. This simple method neglects many were determined in...uniform joist properties.) Designated N-3 for the floor with ’. nailed sheathing and G-3 for the floor with the sheathing 02 attached by means of a rigid

  16. Aerobiology in the operating room and its implications for working standards.

    PubMed

    Friberg, B; Friberg, S

    2005-01-01

    Two novel operating room (OR) ventilation concepts, i.e. the upward displacement or thermal convection system and the exponential ultra-clean laminar air flow (LAF) designed to function without extra walls, were evaluated from a bacteriological point of view. The thermal convection system (17 air changes/h) was compared with conventional ventilation (16 air changes/h) with an air inlet at the ceiling and evacuation at floor level. The exponential LAF was compared with the vertical ultra-clean LAF and the horizontal ultra-clean LAF, both with extra side walls. The comparison was made using strictly standardized simulated operations and, except for the horizontal LAF, it was performed in the same OR where the type of ventilation was changed. In the different areas important for surgical asepsis, the thermal system resulted in a twofold to threefold increase in bacterial air and surface counts compared to the conventional system (statistical significance = p < 0.05-0.0001). The bacteriological efficiency of the exponential LAF was equal to the horizontal and vertical LAF units with extra walls in the OR, and all three systems easily fulfilled the criteria for ultra-clean air, i.e. bacteria-carrying particles < 10/m3. In the areas important for surgical asepsis the turbulent ventilation systems yielded highly significant correlation between air and surface contamination (p < 0.02-0.0006). No such correlation existed in the LAF systems.

  17. RECOMMENDATIONS FOR SAMPLING OF TANK 18 IN F TANK FARM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shine, G.

    2009-12-14

    Representative sampling is required for characterization of the residual floor material in Tank 18 prior to operational closure. Tank 18 is an 85-foot diameter, 34-foot high carbon steel tank with nominal operating volume of 1,300,000 gallons. It is a Type IV tank, and has been in service storing radioactive materials since 1959. Recent mechanical cleaning of the tank removed all mounds of material. Anticipating a low level of solids in the residual material, Huff and Thaxton [2009] developed a plan to sample the material during the final clean-up process while it would still be resident in sufficient quantities to supportmore » analytical determinations in four quadrants of the tank. Execution of the plan produced fewer solids than expected to support analytical determinations in all four quadrants. Huff and Thaxton [2009] then restructured the plan to characterize the residual floor material separately in the North and the South regions: two 'hemispheres.' This document provides sampling recommendations to complete the characterization of the residual material on the tank bottom following the guidance in Huff and Thaxton [2009] to split the tank floor into a North and a South hemisphere. The number of samples is determined from a modification of the formula previously published in Edwards [2001] and the sample characterization data for previous sampling of Tank 18 described by Oji [2009]. The uncertainty is quantified by an upper 95% confidence limit (UCL95%) on each analyte's mean concentration in Tank 18. The procedure computes the uncertainty in analyte concentration as a function of the number of samples, and the final number of samples is determined when the reduction in the uncertainty from an additional sample no longer has a practical impact on results. The characterization of the full suite of analytes in the North hemisphere is currently supported by a single Mantis rover sample obtained from a compact region near the center riser. A floor scrape sample was obtained from a compact region near the northeast riser and has been analyzed for a shortened list of key analytes. Since the unused portion of the floor scrape sample material is archived and available in sufficient quantity, additional analyses need to be performed to complete results for the full suite of constituents. The characterization of the full suite of analytes in the South hemisphere is currently supported by a single Mantis rover sample; there have been no floor scrape samples previously taken from the South hemisphere. The criterion to determine the number of additional samples was based on the practical reduction in the uncertainty when a new sample is added. This was achieved when five additional samples are obtained. In addition, two archived samples will be used if a contingency such as failing to demonstrate the comparability of the Mantis samples to the floor scrape samples occurs. To complete sampling of the Tank 18 residual floor material, three additional samples should be taken from the North hemisphere and four additional samples should be taken from the South hemisphere. One of the samples from each hemisphere will be archived in case of need. Two of the three additional samples from the North hemisphere and three of the four additional samples from the South hemisphere will be analyzed. Once the results are available, differences between the Mantis and three floor scrape samples (the sample previously obtained near NE riser plus the two additional samples that will be analyzed) results will be evaluated. If there are no statistically significant analyte concentration differences between the Mantis and floor scrape samples, those results will be combined and then UCL95%s will be calculated. If the analyte concentration differences between the Mantis and floor scrape samples are statistically significant, the UCL95%s will be calculated without the Mantis sample results. If further reduction in the upper confidence limits is needed and can be achieved by the addition of the archived samples, they will be analyzed and included in the statistical computations. Initially, the analyte concentrations in the residual material on the floor of Tank 18 will be determined separately in the North and the South hemispheres. However, if final sampling results show that differences between the North and South samples are consistent within sampling variation, then the final computations can be based on consolidating all sample results from the tank floor. Recommended locations may be subject to physical tank access and sampling constraints for the additional samples. The recommendations have been discussed in Section 4 and are based on partitioning the Tank 18 floor into an inner and an outer ring and six 60{sup o} sectors depicted in Figure 1. The location of the border between the inner and outer rings is based on dividing the residual material into two approximately equal volumes.« less

  18. Effects of training to implement new tools and working methods to reduce knee load in floor layers.

    PubMed

    Jensen, Lilli Kirkeskov; Friche, Claus

    2007-09-01

    The purpose was to measure the effect of a participatory ergonomics implementation strategy consisting of information, education, and facilitation on the use of new tools and working methods in the floor laying trade. Floor layers (n=292) were trained in using new working methods. The effects were evaluated by using questionnaires, interviews, and assessments of quality and productivity. Following the training, 43% had used the new working methods weekly/daily compared to 11% before. There was a reduction in the degree of self-reported pain in the knees among the floor layers using the new working methods weekly or daily compared to those using them never or occasionally. The musculoskeletal complaints did not increase from any other region and the quality and the productivity of the work were not decreased. This indicates that within a 3-months perspective the implementation strategy succeeded.

  19. A Monocular Vision Sensor-Based Obstacle Detection Algorithm for Autonomous Robots

    PubMed Central

    Lee, Tae-Jae; Yi, Dong-Hoon; Cho, Dong-Il “Dan”

    2016-01-01

    This paper presents a monocular vision sensor-based obstacle detection algorithm for autonomous robots. Each individual image pixel at the bottom region of interest is labeled as belonging either to an obstacle or the floor. While conventional methods depend on point tracking for geometric cues for obstacle detection, the proposed algorithm uses the inverse perspective mapping (IPM) method. This method is much more advantageous when the camera is not high off the floor, which makes point tracking near the floor difficult. Markov random field-based obstacle segmentation is then performed using the IPM results and a floor appearance model. Next, the shortest distance between the robot and the obstacle is calculated. The algorithm is tested by applying it to 70 datasets, 20 of which include nonobstacle images where considerable changes in floor appearance occur. The obstacle segmentation accuracies and the distance estimation error are quantitatively analyzed. For obstacle datasets, the segmentation precision and the average distance estimation error of the proposed method are 81.4% and 1.6 cm, respectively, whereas those for a conventional method are 57.5% and 9.9 cm, respectively. For nonobstacle datasets, the proposed method gives 0.0% false positive rates, while the conventional method gives 17.6%. PMID:26938540

  20. Evaluating the use of laser radiation in cleaning of copper embroidery threads on archaeological Egyptian textiles

    NASA Astrophysics Data System (ADS)

    Abdel-Kareem, Omar; Harith, M. A.

    2008-07-01

    Cleaning of copper embroidery threads on archaeological textiles is still a complicated conservation process, as most textile conservators believe that the advantages of using traditional cleaning techniques are less than their disadvantages. In this study, the uses of laser cleaning method and two modified recipes of wet cleaning methods were evaluated for cleaning of the corroded archaeological Egyptian copper embroidery threads on an archaeological Egyptian textile fabric. Some corroded copper thread samples were cleaned using modified recipes of wet cleaning method; other corroded copper thread samples were cleaned with Q-switched Nd:YAG laser radiation of wavelength 532 nm. All tested metal thread samples before and after cleaning were investigated using a light microscope and a scanning electron microscope with an energy dispersive X-ray analysis unit. Also the laser-induced breakdown spectroscopy (LIBS) technique was used for the elemental analysis of laser-cleaned samples to follow up the laser cleaning procedure. The results show that laser cleaning is the most effective method among all tested methods in the cleaning of corroded copper threads. It can be used safely in removing the corrosion products without any damage to both metal strips and fibrous core. The tested laser cleaning technique has solved the problems caused by other traditional cleaning techniques that are commonly used in the cleaning of metal threads on museum textiles.

  1. Dynamic Testing of In-Situ Composite Floors and Evaluation of Vibration Serviceability Using the Finite Element Method

    DTIC Science & Technology

    2006-08-21

    Dynamic Testing of In-Situ Composite Floors and Evaluation of Vibration Serviceability Using the Finite Element Method By Anthony R. Barrett...Setareh Alfred L. Wicks 21 August 2006 Blacksburg, VA Keywords: vibration, floor, serviceability , walking, modal analysis, fundamental frequency...burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Washington Headquarters Services

  2. Orbital Reconstruction: Patient-Specific Orbital Floor Reconstruction Using a Mirroring Technique and a Customized Titanium Mesh.

    PubMed

    Tarsitano, Achille; Badiali, Giovanni; Pizzigallo, Angelo; Marchetti, Claudio

    2016-10-01

    Enophthalmos is a severe complication of primary reconstruction of orbital floor fractures. The goal of secondary reconstruction procedures is to restore symmetrical globe positions to recover function and aesthetics. The authors propose a new method of orbital floor reconstruction using a mirroring technique and a customized titanium mesh, printed using a direct metal laser-sintering method. This reconstructive protocol involves 4 steps: mirroring of the healthy orbit at the affected site, virtual design of a patient-specific orbital floor mesh, CAM procedures for direct laser-sintering of the customized titanium mesh, and surgical insertion of the device. Using a computed tomography data set, the normal, uninjured side of the craniofacial skeleton was reflected onto the contralateral injured side, and a reconstructive orbital floor mesh was designed virtually on the mirrored orbital bone surface. The solid-to-layer files of the mesh were then manufactured using direct metal laser sintering, which resolves the shaping and bending biases inherent in the indirect method. An intraoperative navigation system ensured accuracy of the entire procedure. Clinical outcomes were assessed using 3dMD photogrammetry and computed tomography data in 7 treated patients. The technique described here appears to be a viable method to correct complex orbital floor defects needing delayed reconstruction. This study represents the first step in the development of a wider experimental protocol for orbital floor reconstruction using computer-assisted design-computer-assisted manufacturing technology.

  3. Cleaning Products and Air Fresheners: Emissions and ResultingConcentrations of Glycol Ethers and Terpenoids

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singer, Brett C.; Destaillat, Hugo; Hodgson, Alfred T.

    2005-08-01

    Experiments were conducted to quantify emissions and concentrations of glycol ethers and terpenoids from cleaning product and air freshener use in a 50-m{sup 3} room ventilated at {approx}0.5 h{sup -1}. Five cleaning products were applied full-strength (FS); three were additionally used in dilute solution. FS application of pine-oil cleaner (POC) yielded 1-h concentrations of 10-1300 {micro}g m{sup -3} for individual terpenoids, including {alpha}-terpinene (90-120), d-limonene (1000-1100), terpinolene (900-1300), and {alpha}-terpineol (260-700). One-hour concentrations of 2-butoxyethanol and/or dlimonene were 300-6000 {micro}g m{sup -3} after FS use of other products. During FS application including rinsing with sponge and wiping with towels, fractionalmore » emissions (mass volatilized/dispensed) of 2-butoxyethanol and d-limonene were 50-100% with towels retained, {approx}25-50% when towels were removed after cleaning. Lower fractions (2-11%) resulted from dilute use. Fractional emissions of terpenes from FS use of POC were {approx}35-70% with towels retained, 20-50% with towels removed. During floor cleaning with dilute solution of POC, 7-12% of dispensed terpenes were emitted. Terpene alcohols were emitted at lower fractions: 7-30% (FS, towels retained), 2-9% (FS, towels removed), and 2-5% (dilute). During air-freshener use, d-limonene, dihydromyrcenol, linalool, linalyl acetate, and {beta}-citronellol were emitted at 35-180 mg d{sup -1} over three days while air concentrations averaged 30-160 {micro}g m{sup -3}.« less

  4. Effect of ammonia on ozone-initiated formation of indoor secondary products with emissions from cleaning products

    NASA Astrophysics Data System (ADS)

    Huang, Yu; Lee, Shun Cheng; Ho, Kin Fai; Ho, Steven Sai Hang; Cao, Nanying; Cheng, Yan; Gao, Yuan

    2012-11-01

    Biogenic volatile organic compounds (BVOCs) emitted from cleaning products and air fresheners indoors are prone to oxidation resulting in the formation of secondary pollutants that can pose health risks on residents. Ammonia (NH3) is ubiquitous in ambient and indoor environments. In this study, we investigated the effect of ammonia (NH3) on secondary pollutants formation from the ozonolysis of BVOCs emitted from cleaning products including floor cleaner (FC), kitchen cleaner (KC) and dishwashing detergent (DD) in a large environmental chamber. Our results demonstrated that the presence of NH3 (maximum concentration is 240 ppb) could significantly enhance secondary organic aerosols (SOAs) formation from the ozonolysis of all the three categories of cleaning products. For example, for the FC sample, the maximum total particle concentration was up to 2.0 × 104 # cm-3 in the presence of NH3, while it was 1.3 × 104 # cm-3 which was 35% lower without NH3. However, it was found that the extent of NH3 effect on SOAs formation from the ozonolysis of BVOCs emissions was component-dependent. The presence of NH3 in the reaction systems could increase the consumptions of d-limonene that is the dominant BVOC species as identified in cleaning products. The percent yields (%) of secondary carbonyl compounds generated from the ozonolysis of BVOCs emitted from three categories of cleaning products were identified in the presence and absence of NH3, respectively. The increase in SOAs particle number concentration can be attributed to the formation of condensable salts from reactions between NH3 and organic compounds generated from the BVOCs ozonolysis processes. By investigating the NH3 effect on the ozonolysis of BVOCs mixtures in contrast to the chemistry of individual compounds, a better assessment can be made of the overall impact cleaning products have on real indoor environments.

  5. An assessment of cleaning and sampling methods for food-contact surfaces in premises preparing and selling high-risk foods.

    PubMed Central

    Tebbutt, G. M.

    1991-01-01

    The performance of agar-contact plates and an alginate-swab method for sampling food surfaces before and after cleaning was compared. Contact plates were more convenient, and were at least as sensitive as the swabbing method. To assess cleaning efficiency repeated sampling was carried out in selected premises, and several cleaning methods were introduced for trial periods. Some surfaces, notably wood and polypropylene, were particularly difficult to clean. For these scrubbing with a nylon brush was the best method. Other surfaces were more easily cleaned, and generally the methods introduced as part of this study were better than the original method used in the premises. Paper proved to be unpopular, and cleaning solutions applied with it did no better than those cleaned with a multiuse cloth kept soaking in a detergent and hypochlorite solution. PMID:1850362

  6. Sozzy: a hormone-driven autonomous vacuum cleaner

    NASA Astrophysics Data System (ADS)

    Yamamoto, Masaki

    1994-02-01

    Domestic robots are promising examples of the application of robotics to personal life. There have been many approaches in this field, but no successful results exist. The problem is that domestic environments are more difficult for robots than other environments, such as factory floors or office floors. Consequently, conventional approaches using a model of human intelligence to design robots have not been successful. In this paper, we report on a prototyped domestic vacuum-cleaning robot that is designed to be able to handle complex environments. The control software is composed of two layers, both of which are generally inspired by behaviors of living creatures. The first layer corresponds to a dynamically reconfigurable system of behaviors implemented in the subsumption architecture. The ability of the robot to support alternate configurations of its behaviors provides the robot with increased robustness. We have conveniently labeled particular configurations as specific `emotions' according to the interpretation of observers of the robot's behavior. The second layer simulates the hormone system. The hormone system is modeled using state variables, increased or decreased by stimuli from the environment. The hormone condition selects the robot's most suitable emotion, according to the changing environments. The robot hardware is built of off-the-shelf parts, such as an embedded CPU, inexpensive home-appliance sensors, and small motors. These parts keep the total building cost to a minimum. The robot also has a vacuum cleaning function to demonstrate its capability to perform useful tasks. We tested the robot in our laboratory, and successfully videotaped its robust behaviors. We also confirmed the hormone system to enhance the robot's plasticity and lifelike quality.

  7. Effect of spray-dried bovine serum on intake, health, and growth of broilers housed in different environments.

    PubMed

    Campbell, J M; Quigley, J D; Russell, L E; Kidd, M T

    2003-11-01

    Three experiments utilizing broilers were conducted in different environments to evaluate the effects of Innavax (INX; spray-dried serum) administered in drinking water on broiler performance. In Exp. 1 (1 to 42 d), 252 Ross x Cobb male broilers were assigned randomly to one of six treatments consisting of tap water mixed with 0, 0.25, 0.50, 0.75, 1.0, or 1.25% (wt/wt) INX. Broilers (six broilers per pen; seven pens per treatment) were housed in Petersime battery cages (raised wire flooring) in temperature-controlled rooms. Average daily gain, and feed and water intake (as-fed) were not affected (P > 0.05) by experimental treatments. Feed efficiency tended to improve linearly (P = 0.076) from d 0 to 7 with increasing levels of INX, but was unaffected (P > 0.05) during the remaining periods. In Exp. 2 and 3, 800 Ross x Ross 308 male broilers (400 broilers in each trial; 10 broilers per pen; 10 pens per treatment) in two 21-d experiments were assigned randomly to one of four treatments consisting of tap water mixed with 0, 0.45, 0.90, or 1.35% (wt/wt) INX. Broilers were housed in floor pens containing clean (Exp. 2) or used (Exp. 3) litter. In Exp. 2, intake, ADG, and feed efficiency were linearly improved (P < 0.05) during the first week with increasing levels of INX. During the second week (d 8 to 14), ADG, water intake, and feed efficiency were linearly improved (P < 0.05) with increasing levels of INX. In the third week (d 15 to 21), ADG and feed and water intake were not affected (P > 0.10) by level of INX. Overall (d 0 to 21), ADG, intake, and feed efficiency were linearly improved (P < 0.05) with INX. In Exp. 3, ADG, water intake, and feed efficiency were linearly improved (P < 0.05) during each period. Feed intake was not affected (P > 0.05) by experimental treatment during d 0 to 7, but was linearly increased (P < 0.05) from d 8 to 14 and 15 to 21. The greatest growth response of broilers to INX was observed when broilers were housed in floor pens with used litter, followed by floor pens with clean litter and battery pens. Further research on the relationship between the response to INX and housing conditions seems warranted.

  8. Mouse Cleaning Apparatus and Method

    NASA Technical Reports Server (NTRS)

    Williams, Glenn L. (Inventor)

    2005-01-01

    The method of using the mouse pad cleaning apparatus is disclosed and claimed. The method comprises the steps of uncovering the mouse cleaning surface, applying the mouse and ball of the mouse to the cleaning surface, moving the mouse in a rotational pattern on the mouse cleaning surface, removing the mouse form the mouse cleaning surface, washing the cleaning surface, and covering the mouse cleaning surface. A mouse pad cleaning apparatus comprising a plurality of substrates, each said substrate having adhesive thereon, said plurality of substrates residing in and affixed to a receptacle. A single substrate having adhesive, which may be washable or non-washable, thereon may be employed. The washable adhesive may be an organopolysiloxane or gelatinous elastomer.

  9. Remediation of Mercury-Contaminated Storm Sewer Sediments from the West End Mercury Area at the Y-12 National Security Complex in Oak Ridge, Tennessee - 12061

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tremaine, Diana; Douglas, Steven G.

    2012-07-01

    The Y-12 National Security Complex in Oak Ridge, TN has faced an ongoing challenge from mercury entrapped in soils beneath and adjacent to buildings, storm sewers, and process pipelines. Previous actions to reduce the quantity and/or mobilization of mercury-contaminated media have included plugging of building floor drains, cleaning of sediment and sludge from sumps, manholes, drain lines, and storm sewers, lining/relining of storm sewers and replacement of a portion of the storm sewer trunk line, re-routing and removal of process piping, and installation of the Central Mercury Treatment System to capture and treat contaminated sump water. Despite the success ofmore » these actions, mercury flux in the storm sewer out-falls that discharge to Upper East Fork Poplar Creek (UEFPC) continues to pose a threat to long-term water quality. A video camera survey of the storm sewer network revealed several sections of storm sewer that had large cracks, separations, swells, and accumulations of sediment/sludge and debris. The selected remedy was to clean and line the sections of storm sewer pipe that were determined to be primary contributors to the mercury flux in the storm sewer out-falls. The project, referred to as the West End Mercury Area (WEMA) Storm Sewer Remediation Project, included cleaning sediment and debris from over 2,460 meters of storm sewer pipe followed by the installation of nearly 366 meters of cure-in-place pipe (CIPP) liner. One of the greatest challenges to the success of this project was the high cost of disposal associated with the mercury-contaminated sludge and wastewater generated from the storm sewer cleaning process. A contractor designed and operated an on-site wastewater pre-treatment system that successfully reduced mercury levels in 191 cubic meters of sludge to levels that allowed it to be disposed at Nevada Nuclear Security Site (NNSS) disposal cell as a non-hazardous, low-level waste. The system was also effective at pre-treating over 1,514,000 liters of wastewater to levels that met the waste acceptance criteria for the on-site West End [wastewater] Treatment Facility (WETF). This paper describes the storm sewer cleaning and lining process and the methods used to process the mercury-contaminated sludge and wastewater, as well as several 'lessons learned' that would be relevant to any future projects involving storm sewer cleaning and debris remediation. (authors)« less

  10. Cleaning products and air fresheners: emissions and resulting concentrations of glycol ethers and terpenoids.

    PubMed

    Singer, B C; Destaillats, H; Hodgson, A T; Nazaroff, W W

    2006-06-01

    Experiments were conducted to quantify emissions and concentrations of glycol ethers and terpenoids from cleaning product and air freshener use in a 50-m3 room ventilated at approximately 0.5/h. Five cleaning products were applied full-strength (FS); three were additionally used in dilute solution. FS application of pine-oil cleaner (POC) yielded 1-h concentrations of 10-1300 microg/m3 for individual terpenoids, including alpha-terpinene (90-120), d-limonene (1000-1100), terpinolene (900-1300), and alpha-terpineol (260-700). One-hour concentrations of 2-butoxyethanol and/or d-limonene were 300-6000 microg/m3 after FS use of other products. During FS application including rinsing with sponge and wiping with towels, fractional emissions (mass volatilized/dispensed) of 2-butoxyethanol and d-limonene were 50-100% with towels retained, and approximately 25-50% when towels were removed after cleaning. Lower fractions (2-11%) resulted from dilute use. Fractional emissions of terpenes from FS use of POC were approximately 35-70% with towels retained, and 20-50% with towels removed. During floor cleaning with dilute solution of POC, 7-12% of dispensed terpenes were emitted. Terpene alcohols were emitted at lower fractions: 7-30% (FS, towels retained), 2-9% (FS, towels removed), and 2-5% (dilute). During air-freshener use, d-limonene, dihydromyrcenol, linalool, linalyl acetate, and beta-citronellol) were emitted at 35-180 mg/day over 3 days while air concentrations averaged 30-160 microg/m3. While effective cleaning can improve the healthfulness of indoor environments, this work shows that use of some consumer cleaning agents can yield high levels of volatile organic compounds, including glycol ethers--which are regulated toxic air contaminants--and terpenes that can react with ozone to form a variety of secondary pollutants including formaldehyde and ultrafine particles. Persons involved in cleaning, especially those who clean occupationally or often, might encounter excessive exposures to these pollutants owing to cleaning product emissions. Mitigation options include screening of product ingredients and increased ventilation during and after cleaning. Certain practices, such as the use of some products in dilute solution vs. full-strength and the prompt removal of cleaning supplies from occupied spaces, can reduce emissions and exposures to 2-butoxyethanol and other volatile constituents. Also, it may be prudent to limit use of products containing ozone-reactive constituents when indoor ozone concentrations are elevated either because of high ambient ozone levels or because of the indoor use of ozone-generating equipment.

  11. Incidence of Listeria spp. in Ready-to-Eat Food Processing Plant Environments Regulated by the U.S. Food Safety and Inspection Service and the U.S. Food and Drug Administration.

    PubMed

    Reinhard, Robert G; Kalinowski, Robin M; Bodnaruk, Peter W; Eifert, Joseph D; Boyer, Renee R; Duncan, Susan E; Bailey, R Hartford

    2018-06-07

    A multiyear survey of 31 ready-to-eat (RTE) food processing plants in the United States was conducted to determine the incidence of Listeria spp. in various RTE production environments. Samples were collected from 22 RTE plants regulated by the U.S. Department of Agriculture's Food Safety and Inspection Service (FSIS) and from 9 RTE food plants regulated by the U.S. Department of Health and Human Services' Food and Drug Administration (FDA). Only nonfood contact surfaces in the RTE manufacturing areas with exposed RTE product were sampled. Each sample was individually analyzed for the presence of Listeria spp. by using a PCR-based rapid assay. In total, 4,829 samples were collected from various locations, including freezers, equipment framework, floors, walls, wall-floor junctures, drains, floor mats, doors, and cleaning tools. Nine (29%) of the facilities had zero samples positive for Listeria spp. in the production environment, whereas 22 (71%) had one or more samples positive for Listeria spp. The total incidence of Listeria spp. in all RTE food plants was 4.5%. The positive rate in plants regulated by the FSIS ranged from 0 to 9.7%, whereas the positive rate in plants regulated by the FDA ranged from 1.2 to 36%.

  12. Prime Contract Awards by Service Category and Federal Supply Classification, Fiscal Years 1993, 1992, 1991 and 1990

    DTIC Science & Technology

    1993-01-01

    491 373 7830 Recreational and Gymnastic Equipment 6,834 5,823 6,811 5,119 TOTAL Recreational and Athletic Equipment 9,031 11,526 11,175 9.065 Cleaning...8010 Paints, Dopes, Varnishes & Related Product 7,755 5,137 6,586 6,130 8020 Paint and Artists ’ Brushes 0 227- 963 08030 Preservative and Sealing...0 0 0 7820 Games, Toys and Wheeled Goods 656 300 83 273 0 0 0 7830 Recreational and Gymnastic Equipment 6,834 2,003 1.169 3,661 0 0 0 7910 Floor

  13. Real-time modeling of heat distributions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hamann, Hendrik F.; Li, Hongfei; Yarlanki, Srinivas

    Techniques for real-time modeling temperature distributions based on streaming sensor data are provided. In one aspect, a method for creating a three-dimensional temperature distribution model for a room having a floor and a ceiling is provided. The method includes the following steps. A ceiling temperature distribution in the room is determined. A floor temperature distribution in the room is determined. An interpolation between the ceiling temperature distribution and the floor temperature distribution is used to obtain the three-dimensional temperature distribution model for the room.

  14. Comparative study between chemical and atmospheric pressure plasma jet cleaning on glass substrate

    NASA Astrophysics Data System (ADS)

    Elfa, Rizan Rizon; Ahmad, Mohd Khairul; Fhong, Soon Chin; Sahdan, Mohd Zainizan; Nayan, Nafarizal

    2017-01-01

    The atmospheric pressure plasma jet with low frequency and argon as working gas is presented in this paper to demonstrate its application for glass substrate clean and modification. The glass substrate clean by atmospheric pressure plasma jet is an efficient method to replace other substrate clean method. A comparative analysis is done in this paper between substrate cleaned by chemical and plasma treatment methods. Water contact angle reading is taken for a different method of substrate clean and period of treatment. Under the plasma treatment, the sample shows low surface adhesion due to having the surface property of super hydrophilic surface 7.26°. This comparative analysis is necessary in the industrial application for cost production due to sufficient time and method of substrate clean.

  15. Real-Time Generation of the Footprints both on Floor and Ground

    NASA Astrophysics Data System (ADS)

    Hirano, Yousuke; Tanaka, Toshimitsu; Sagawa, Yuji

    This paper presents a real-time method for generating various footprints in relation to state of walking. In addition, the method is expanded to cover both on hard floor and soft ground. Results of the previous method were not so realistic, because the method places same simple foot prints on the motion path. Our method runs filters on the original pattern of footprint on GPU. And then our method gradates intensity of the pattern to two directions, in order to create partially dark footprints. Here parameters of the filter and the gradation are changed by move speed and direction. The pattern is mapped on a polygon. If the walker is pigeon-toed or bandy-legged, the polygon is rotated inside or outside, respectively. Finally, it is placed on floor. Footprints on soft ground are concavity and convexity caused by walking. Thus an original pattern of footprints on ground is defined as a height map. The height map is modified using the filter and the gradation operation developed for floor footprints. The height map is converted to a bump map to fast display the concavity and convexity of footprints.

  16. Postdischarge decontamination of MRSA, VRE, and Clostridium difficile isolation rooms using 2 commercially available automated ultraviolet-C-emitting devices.

    PubMed

    Wong, Titus; Woznow, Tracey; Petrie, Mike; Murzello, Elena; Muniak, Allison; Kadora, Amin; Bryce, Elizabeth

    2016-04-01

    Two ultraviolet-C (UVC)-emitting devices were evaluated for effectiveness in reducing methicillin-resistant Staphylococcus aureus (MRSA), vancomycin-resistant enterococci (VRE), and Clostridium difficile (CD). Six surfaces in rooms previously occupied by patients with MRSA, VRE, or CD were cultured before and after cleaning and after UVC disinfection. In a parallel laboratory study, MRSA and VRE suspended in trypticase soy broth were inoculated onto stainless steel carriers in triplicate, placed in challenging room areas, subjected to UVC, and subcultured to detect growth. Sixty-one rooms and 360 surfaces were assessed. Before cleaning, MRSA was found in 34.4%, VRE was found in 29.5%, and CD was found in 31.8% of rooms. Cleaning reduced MRSA-, VRE-, and CD-contaminated rooms to 27.9%, 29.5%, and 22.7%, respectively (not statistically significant). UVC disinfection further reduced MRSA-, VRE-, and CD-contaminated rooms to 3.3% (P = .0003), 4.9% (P = .0003), and 0% (P = .0736), respectively. Surface colony counts (excluding floors) decreased from 88.0 to 19.6 colony forming units (CFU) (P < .0001) after manual cleaning; UVC disinfection further reduced it to 1.3 CFU (P = .0013). In a multivariable model of the carrier study, the odds of detecting growth in broth suspensions after UVC disinfection were 7 times higher with 1 machine (odds ratio, 6.96; 95% confidence interval, 3.79-13.4) for a given organism, surface, and concentration. UVC devices are effective adjuncts to manual cleaning but vary in their ability to disinfect high concentrations of organisms in the presence of protein. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  17. [A strategy for assessing environmental influence on airway allergy using a regression binary tree-based method].

    PubMed

    Yoshioka, Fumi; Azuma, Emiko; Nakajima, Takae; Hashimoto, Masafumi; Toyoshima, Kyoichiro; Komachi, Yoshio

    2004-08-01

    To clarify the living environment factors that increase the risk of allergic sensitization to house dust mites, we applied a regression binary tree-based method (CART, Classification & Regression Trees) to an epidemiological study on airway allergy. The utility of the tree map in personal sanitary guidance for preventing allergic sensitization was examined with respect to feasibility and validity. A questionnaire was given to 386 healthy adult women, asking them about their individual living environments. Also, blood samples were collected to measure Dermatophagoides pteronyssinus (Dp)-specific IgE, the presence/absence of Dp-sensitization being expressed as positive/negative. The questionnaire consisted of nine items on (1) home ventilation by keeping windows open, (2) personal or family smoking habits, (3) use of air conditioners in hot weather, (4) type of flooring (tatami/wooden/carpet) in the living room, (5) visible mold proliferation in the kitchen, (6) type of housing (concrete/wooden), (7) residential area (heavy or light traffic area) (8) heating system (use of unventilated combustion appliances), and (9) frequency of cleaning (every day or less often). There also were queries on the past history of airway allergic diseases, such as bronchial asthma and allergic rhinitis. CART and a multivariate logistic regression analysis (MLRA) were performed. The subjects were first classified into two groups, with and without a history of airway allergic diseases (Groups WPH and WOPH). In each group, the involvement of living environment factors in Dp-sensitization was examined using CART and MLRA. In the MLRA study, individual living environment factors showed promotional or suppressive effects on Dp-sensitization with differences between the two groups. With respect to the CART results, the two groups were first split by the factor that had the most significant odds ratio for MLRA. In Group WPH, which had a Dp-sensitization risk of 19.5%, the first split was by the factor of visible mold proliferation in the kitchen into the factor-present group with a risk value of 45.5% and the factor-absent group with 13.5%. The mold proliferation group was split with reference to frequent cleaning, and the risk rose to 75% in the factor-absent group and to 100% when family smoking habits were reported. Group WOPH (the risk: 10.8%) was first split into two groups according to the use of air conditioners in hot weather for more than 6 hours a day or less, which showed risk values of 16.7% and 6.9%, respectively. The risk of the group that intensively used air conditioners fell to 8.3% with tatami as flooring in the living room, and, if others, rose to 20.8%. The risk of the factor-lacking group fell to 4.0% without wooden flooring. CART analysis enables us to express complex relationships between living environment factors and Dp-sensitization simply by a binary regression tree, pointing to preventive strategies that can be flexibly changed according to the individual living environments of the subjects.

  18. Deflection of Resilient Materials for Reduction of Floor Impact Sound

    PubMed Central

    Lee, Jung-Yoon; Kim, Jong-Mun

    2014-01-01

    Recently, many residents living in apartment buildings in Korea have been bothered by noise coming from the houses above. In order to reduce noise pollution, communities are increasingly imposing bylaws, including the limitation of floor impact sound, minimum thickness of floors, and floor soundproofing solutions. This research effort focused specifically on the deflection of resilient materials in the floor sound insulation systems of apartment houses. The experimental program involved conducting twenty-seven material tests and ten sound insulation floating concrete floor specimens. Two main parameters were considered in the experimental investigation: the seven types of resilient materials and the location of the loading point. The structural behavior of sound insulation floor floating was predicted using the Winkler method. The experimental and analytical results indicated that the cracking strength of the floating concrete floor significantly increased with increasing the tangent modulus of resilient material. The deflection of the floating concrete floor loaded at the side of the specimen was much greater than that of the floating concrete floor loaded at the center of the specimen. The Winkler model considering the effect of modulus of resilient materials was able to accurately predict the cracking strength of the floating concrete floor. PMID:25574491

  19. Deflection of resilient materials for reduction of floor impact sound.

    PubMed

    Lee, Jung-Yoon; Kim, Jong-Mun

    2014-01-01

    Recently, many residents living in apartment buildings in Korea have been bothered by noise coming from the houses above. In order to reduce noise pollution, communities are increasingly imposing bylaws, including the limitation of floor impact sound, minimum thickness of floors, and floor soundproofing solutions. This research effort focused specifically on the deflection of resilient materials in the floor sound insulation systems of apartment houses. The experimental program involved conducting twenty-seven material tests and ten sound insulation floating concrete floor specimens. Two main parameters were considered in the experimental investigation: the seven types of resilient materials and the location of the loading point. The structural behavior of sound insulation floor floating was predicted using the Winkler method. The experimental and analytical results indicated that the cracking strength of the floating concrete floor significantly increased with increasing the tangent modulus of resilient material. The deflection of the floating concrete floor loaded at the side of the specimen was much greater than that of the floating concrete floor loaded at the center of the specimen. The Winkler model considering the effect of modulus of resilient materials was able to accurately predict the cracking strength of the floating concrete floor.

  20. Evaluation of two working methods for screed floor layers on musculoskeletal complaints, work demands and workload.

    PubMed

    Visser, Steven; van der Molen, Henk F; Kuijer, P Paul F M; van Holland, Berry J; Frings-Dresen, Monique H W

    2013-01-01

    Screed floors are bound by sand-cement (SF) or by anhydrite (AF). Sand-cement floors are levelled manually and anhydrite floors are self-levelling and therefore differences in work demands and prevalences of musculoskeletal complaints might occur. The objective was to assess among SF layers and AF layers (1) the prevalence of musculoskeletal complaints and (2) the physical work demands, energetic workload, perceived workload and discomfort. A questionnaire survey and an observational field study were performed. Compared with AF layers (n = 35), SF layers (n = 203) had higher, however, not statistically significant different, prevalences of neck (20% vs. 7%), shoulder (27% vs. 13%), low back (39% vs. 26%) and ankles/feet (9% vs. 0%) complaints. Sand-cement-bound screed floor layers (n = 18) bent and kneeled significantly longer (Δ77 min and Δ94 min; respectively), whereas AF layers (n = 18) stood significantly longer (Δ60 min). The work demands of SF layers exceeded exposure criteria for low back and knee complaints and therefore new working measures should be developed and implemented. In comparison with anhydrite-bound screed floor layers, sand-cement-bound screed floor layers exceeded exposure criteria for work-related low back and knee complaints. New working methods and measures for sand-cement-bound screed floor layers should be developed and implemented to reduce the risk for work-related musculoskeletal complaints.

  1. Elevated waterproof access floor system and method of making the same

    NASA Technical Reports Server (NTRS)

    Cohen, Marc M. (Inventor)

    1987-01-01

    An elevated waterproof access floor system having subfloor channels or compartments for power lines, gas lines or the like is adapted such that it can be opened and subsequently resealed without destroying the waterproofing and without destroying its aesthetic appearance. A multiplicity of tiles are supported on a support grid, and a flooring sheet is supported on the tiles. Attachment means are provided to prevent lateral but not vertical movement of the flooring sheet with respect to the tiles so that the flooring sheet can be lifted off the tiles, but when the flooring sheet is supported on the tiles, no lateral slipping will occur. The flooring sheet is made of a heat resealable material, so that it can be cut away in sections, and the tiles therebelow lifted off, to provide access to subfloor compartments.

  2. Beyond the floor effect on the Wechsler Intelligence Scale for Children--4th Ed. (WISC-IV): calculating IQ and Indexes of subjects presenting a floored pattern of results.

    PubMed

    Orsini, A; Pezzuti, L; Hulbert, S

    2015-05-01

    It is now widely known that children with severe intellectual disability show a 'floor effect' on the Wechsler scales. This effect emerges because the practice of transforming raw scores into scaled scores eliminates any variability present in participants with low intellectual ability and because intelligence quotient (IQ) scores are limited insofar as they do not measure scores lower than 40. Following Hessl et al.'s results, the present authors propose a method for the computation of the Wechsler Intelligence Scale for Children--4th Ed. (WISC-IV)'s IQ and Indexes in intellectually disabled participants affected by a floored pattern of results. The Italian standardization sample (n = 2200) for the WISC-IV was used. The method presented in this study highlights the limits of the 'floor effect' of the WISC-IV in children with serious intellectual disability who present a profile with weighted scores of 1 in all the subtests despite some variability in the raw scores. Such method eliminates the floor effect of the scale and therefore makes it possible to analyse the strengths and weaknesses of the WISC-IV's Indexes in these participants. The Authors reflect on clinical utility of this method and on the meaning of raw score of 0 on subtest. © 2014 MENCAP and International Association of the Scientific Study of Intellectual and Developmental Disabilities and John Wiley & Sons Ltd.

  3. Light-frame wall and floor systems : analysis and performance

    Treesearch

    G. Sherwood; R. C. Moody

    1989-01-01

    This report describes methods of predicting the performance of light-frame wood structures with emphasis on floor and wall systems. Methods of predicting structural performance, fire safety, and environmental concerns including thermal, moisture, and acoustic performance are addressed in the three major sections.

  4. RECOMMENDATIONS FOR SAMPLING OF TANK 19 IN F TANK FARM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harris, S.; Shine, G.

    2009-12-14

    Representative sampling is required for characterization of the residual material in Tank 19 prior to operational closure. Tank 19 is a Type IV underground waste storage tank located in the F-Tank Farm. It is a cylindrical-shaped, carbon steel tank with a diameter of 85 feet, a height of 34.25 feet, and a working capacity of 1.3 million gallons. Tank 19 was placed in service in 1961 and initially received a small amount of low heat waste from Tank 17. It then served as an evaporator concentrate (saltcake) receiver from February 1962 to September 1976. Tank 19 also received the spentmore » zeolite ion exchange media from a cesium removal column that once operated in the Northeast riser of the tank to remove cesium from the evaporator overheads. Recent mechanical cleaning of the tank removed all mounds of material. Anticipating a low level of solids in the residual waste, Huff and Thaxton [2009] developed a plan to sample the waste during the final clean-up process while it would still be resident in sufficient quantities to support analytical determinations in four quadrants of the tank. Execution of the plan produced fewer solids than expected to support analytical determinations in all four quadrants. Huff and Thaxton [2009] then restructured the plan to characterize the residual separately in the North and the South regions: two 'hemispheres.' This document provides sampling recommendations to complete the characterization of the residual material on the tank bottom following the guidance in Huff and Thaxton [2009] to split the tank floor into a North and a South hemisphere. The number of samples is determined from a modification of the formula previously published in Edwards [2001] and the sample characterization data for previous sampling of Tank 19 described by Oji [2009]. The uncertainty is quantified by an upper 95% confidence limit (UCL95%) on each analyte's mean concentration in Tank 19. The procedure computes the uncertainty in analyte concentration as a function of the number of samples, and the final number of samples is determined when the reduction in the uncertainty from an additional sample no longer has a practical impact on results. The characterization of the full suite of analytes in the North and South hemispheres is currently supported by a single Mantis rover sample in each hemisphere. A floor scrape sample was obtained from a compact region near the center riser slightly in the South hemisphere and has been analyzed for a shortened list of key analytes. There is not enough additional material from the floor scrape sample material for completing the full suite of constituents. No floor scrape samples have been previously taken from the North hemisphere. The criterion to determine the number of additional samples was based on the practical reduction in the uncertainty when a new sample is added. This was achieved when five additional samples are obtained. In addition, two archived samples will be used if a contingency such as failing to demonstrate the comparability of the Mantis samples to the floor scrape samples occurs. To complete sampling of the Tank 19 residual floor material, four additional samples should be taken from the North hemisphere and four additional samples should be taken from the South hemisphere. One of the samples from each hemisphere will be archived in case of need. Three of the four additional samples from each hemisphere will be analyzed. Once the results are available, differences between the Mantis and three floor scrape sample results will be evaluated. If there are no statistically significant analyte concentration differences between the Mantis and floor scrape samples, those results will be combined and then UCL95%s will be calculated. If the analyte concentration differences between the Mantis and floor scrape samples are statistically significant, the UCL95%s will be calculated without the Mantis sample results. If further reduction in the upper confidence limits is needed and can be achieved by the addition of the archived samples, they will be analyzed and included in the statistical computations. Initially the analyte concentrations in the residual material on the floor of Tank 19 will be determined separately in the North and the South hemispheres. However, if final sampling results show that differences between the North and South samples are consistent within sampling variation, then the final computations can be based on consolidating all sample results from the tank floor. Recommended locations may be subject to physical tank access and sampling constraints for the additional samples. The recommendations have been discussed in Section 4 and are based on partitioning the Tank 19 floor into an inner and an outer ring and six 60{sup o} sectors depicted in Figure 1. The location of the border between the inner and outer rings is based on dividing the residual material into two approximately equal volumes.« less

  5. Precision cleaning apparatus and method

    DOEpatents

    Schneider, T.W.; Frye, G.C.; Martin, S.J.

    1998-01-13

    A precision cleaning apparatus and method are disclosed. The precision cleaning apparatus includes a cleaning monitor further comprising an acoustic wave cleaning sensor such as a quartz crystal microbalance (QCM), a flexural plate wave (FPW) sensor, a shear horizontal acoustic plate mode (SH--APM) sensor, or a shear horizontal surface acoustic wave (SH--SAW) sensor; and measurement means connectable to the sensor for measuring in-situ one or more electrical response characteristics that vary in response to removal of one or more contaminants from the sensor and a workpiece located adjacent to the sensor during cleaning. Methods are disclosed for precision cleaning of one or more contaminants from a surface of the workpiece by means of the cleaning monitor that determines a state of cleanliness and any residual contamination that may be present after cleaning; and also for determining an effectiveness of a cleaning medium for removing one or more contaminants from a workpiece. 11 figs.

  6. Precision cleaning apparatus and method

    DOEpatents

    Schneider, Thomas W.; Frye, Gregory C.; Martin, Stephen J.

    1998-01-01

    A precision cleaning apparatus and method. The precision cleaning apparatus includes a cleaning monitor further comprising an acoustic wave cleaning sensor such as a quartz crystal microbalance (QCM), a flexural plate wave (FPW) sensor, a shear horizontal acoustic plate mode (SH--APM) sensor, or a shear horizontal surface acoustic wave (SH--SAW) sensor; and measurement means connectable to the sensor for measuring in-situ one or more electrical response characteristics that vary in response to removal of one or more contaminants from the sensor and a workpiece located adjacent to the sensor during cleaning. Methods are disclosed for precision cleaning of one or more contaminants from a surface of the workpiece by means of the cleaning monitor that determines a state of cleanliness and any residual contamination that may be present after cleaning; and also for determining an effectiveness of a cleaning medium for removing one or more contaminants from a workpiece.

  7. Physical and cultural determinants of postpartum pelvic floor support and symptoms following vaginal delivery: a protocol for a mixed-methods prospective cohort study

    PubMed Central

    Nygaard, Ingrid E; Clark, Erin; Clark, Lauren; Egger, Marlene J; Hitchcock, Robert; Hsu, Yvonne; Norton, Peggy; Sanchez-Birkhead, Ana; Shaw, Janet; Sheng, Xiaoming; Varner, Michael

    2017-01-01

    Introduction Pelvic floor disorders (PFDs), including pelvic organ prolapse (POP), stress and urgency urinary incontinence, and faecal incontinence, are common and arise from loss of pelvic support. Although severe disease often does not occur until women become older, pregnancy and childbirth are major risk factors for PFDs, especially POP. We understand little about modifiable factors that impact pelvic floor function recovery after vaginal birth. This National Institutes of Health (NIH)-funded Program Project, ‘Bridging physical and cultural determinants of postpartum pelvic floor support and symptoms following vaginal delivery’, uses mixed-methods research to study the influences of intra-abdominal pressure, physical activity, body habitus and muscle fitness on pelvic floor support and symptoms as well as the cultural context in which women experience those changes. Methods and analysis Using quantitative methods, we will evaluate whether pelvic floor support and symptoms 1 year after the first vaginal delivery are affected by biologically plausible factors that may impact muscle, nerve and connective tissue healing during recovery (first 8 weeks postpartum) and strengthening (remainder of the first postpartum year). Using qualitative methods, we will examine cultural aspects of perceptions, explanations of changes in pelvic floor support, and actions taken by Mexican-American and Euro-American primipara, emphasising early changes after childbirth. We will summarise project results in a resource toolkit that will enhance opportunities for dialogue between women, their families and providers, and across lay and medical discourses. We anticipate enrolling up to 1530 nulliparous women into the prospective cohort study during the third trimester, following those who deliver vaginally 1 year postpartum. Participants will be drawn from this cohort to meet the project's aims. Ethics and dissemination The University of Utah and Intermountain Healthcare Institutional Review Boards approved this study. Data are stored in a secure password-protected database. Papers summarising the primary results and ancillary analyses will be published in peer-reviewed journals. PMID:28073797

  8. No Concentration Decrease of House Dust Mite Allergens With Rising Altitude in Alpine Regions

    PubMed Central

    Grafetstätter, Carina; Prossegger, Johanna; Braunschmid, Herbert; Sanovic, Renata; Hahne, Penelope; Pichler, Christina; Thalhamer, Josef

    2016-01-01

    Purpose Several studies over the past 4 decades have indicated a significant reduction in house dust mite (HDM) and HDM allergen concentration in areas higher than 1,500 m above sea level. These have served as basis of allergen avoidance therapies for HDM allergy and asthma. However, modern construction techniques used in the insulation, heating, and glazing of buildings as well as global warming have changed the environmental parameters for HDM living conditions. The present study revisits the paradigm of decreasing HDM allergen concentrations with increasing altitude in the alpine region of Germany and Austria. Methods A total of 122 dust samples from different abodes (hotels, privates and mountain huts) at different altitudes (400-2,600 m) were taken, and concentrations of HDM allergens were analyzed. Humidity and temperature conditions, and numerous indoor environmental parameters such as fine dust, type of flooring, age of building, and frequency of cleaning were determined. Results HDM allergen concentrations did not significantly change with increasing altitude or relative humidity. At the level of indoor parameters, correlations could be found for different flooring types and the concentration of HDM allergens. Conclusions In contrast to the widespread view of the relationship between altitude and HDM allergen concentrations, clinically relevant concentrations of HDM allergens could be detected in high-lying alpine regions in Austria and Germany. These results indicate that improvement in conditions of asthmatic patients sensitized against HDMs during a stay at high altitude can no longer be ascribed to decreased levels of HDM allergens, instead, other mechanisms may trigger the beneficial effect. PMID:27126724

  9. Robots remove explosive waste from flooded site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1993-10-01

    Explosive industrial waste can remain hazardous for years, making remediation extremely dangerous, particularly when using traditional methods involving people and manually operated equipment. The work is even more complex if the waste is submerged. Authorities in 1988 faced an unusual challenge when they decided to clean up a flooded area that had been used for more than 30 years as a dump for explosive materials. They devised an innovative but highly effective solution. Instead of using divers, two robots perform the cleanup while site personnel remain 600 feet away from the restricted area. The robots were developed by Sonsub Environmentalmore » Services Inc. (Houston), which is responsible for their operation. The robots initially located and cleared a small area underwater to set up a metal-processing system, which also was designed by Sonsub. The system is similar to a metal-recycling shredder. The robots then assembled the 25-foot-tall, 20-ton system 60 feet below the surface on the pit floor. A large, surface robot carried sections of the shredder to the cleared area and lowered them, while a smaller, submersible robot guided them into position. This required extreme precision by the smaller robot, which had to ensure that sections mated properly. Both robots now retrieve waste from the pit bottom and feed it into the shredder. The larger robot has a 40-foot jointed arm for lifting up to 1,000 pounds of debris, a manipulator hand for sorting through rock piles and removing small containers, and a grapple for picking up items from the pit floor.« less

  10. An evaluation of the efficiency of cleaning methods in a bacon factory

    PubMed Central

    Dempster, J. F.

    1971-01-01

    The germicidal efficiencies of hot water (140-150° F.) under pressure (method 1), hot water + 2% (w/v) detergent solution (method 2) and hot water + detergent + 200 p.p.m. solution of available chlorine (method 3) were compared at six sites in a bacon factory. Results indicated that sites 1 and 2 (tiled walls) were satisfactorily cleaned by each method. It was therefore considered more economical to clean such surfaces routinely by method 1. However, this method was much less efficient (31% survival of micro-organisms) on site 3 (wooden surface) than methods 2 (7% survival) and 3 (1% survival). Likewise the remaining sites (dehairing machine, black scraper and table) were least efficiently cleaned by method 1. The most satisfactory results were obtained when these surfaces were treated by method 3. Pig carcasses were shown to be contaminated by an improperly cleaned black scraper. Repeated cleaning and sterilizing (method 3) of this equipment reduced the contamination on carcasses from about 70% to less than 10%. PMID:5291745

  11. Failure analysis in the identification of synergies between cleaning monitoring methods.

    PubMed

    Whiteley, Greg S; Derry, Chris; Glasbey, Trevor

    2015-02-01

    The 4 monitoring methods used to manage the quality assurance of cleaning outcomes within health care settings are visual inspection, microbial recovery, fluorescent marker assessment, and rapid ATP bioluminometry. These methods each generate different types of information, presenting a challenge to the successful integration of monitoring results. A systematic approach to safety and quality control can be used to interrogate the known qualities of cleaning monitoring methods and provide a prospective management tool for infection control professionals. We investigated the use of failure mode and effects analysis (FMEA) for measuring failure risk arising through each cleaning monitoring method. FMEA uses existing data in a structured risk assessment tool that identifies weaknesses in products or processes. Our FMEA approach used the literature and a small experienced team to construct a series of analyses to investigate the cleaning monitoring methods in a way that minimized identified failure risks. FMEA applied to each of the cleaning monitoring methods revealed failure modes for each. The combined use of cleaning monitoring methods in sequence is preferable to their use in isolation. When these 4 cleaning monitoring methods are used in combination in a logical sequence, the failure modes noted for any 1 can be complemented by the strengths of the alternatives, thereby circumventing the risk of failure of any individual cleaning monitoring method. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  12. A walk through the planned CS building. M.S. Thesis

    NASA Technical Reports Server (NTRS)

    Khorramabadi, Delnaz

    1991-01-01

    Using the architectural plan views of our future computer science building as test objects, we have completed the first stage of a Building walkthrough system. The inputs to our system are AutoCAD files. An AutoCAD converter translates the geometrical information in these files into a format suitable for 3D rendering. Major model errors, such as incorrect polygon intersections and random face orientations, are detected and fixed automatically. Interactive viewing and editing tools are provided to view the results, to modify and clean the model and to change surface attributes. Our display system provides a simple-to-use user interface for interactive exploration of buildings. Using only the mouse buttons, the user can move inside and outside the building and change floors. Several viewing and rendering options are provided, such as restricting the viewing frustum, avoiding wall collisions, and selecting different rendering algorithms. A plan view of the current floor, with the position of the eye point and viewing direction on it, is displayed at all times. The scene illumination can be manipulated, by interactively controlling intensity values for 5 light sources.

  13. Observations related to the Salmonella EU layer baseline survey in the United Kingdom: follow-up of positive flocks and sensitivity issues.

    PubMed

    Carrique-Mas, J J; Breslin, M; Snow, L; Arnold, M E; Wales, A; McLaren, I; Davies, R H

    2008-11-01

    A follow-on study was carried out on 23 holdings identified as Salmonella positive in the 2004/2005 European Union (EU) baseline survey of Salmonella in laying hens. Eleven of 13 cage and 4/7 floor houses remained positive for Salmonella when the new flock was tested, and from 10/13 cage and 3/7 floor houses a Salmonella of the same serovar/phage type as found in the EU survey was isolated. There was a high correlation between the level of contamination in the houses at the time of the EU survey and in the follow-on flock. On seven occasions the house identified as positive in the EU survey was sampled after cleaning and disinfection but before a new flock was placed, and in all of them Salmonella could be isolated from the houses. The observed number of infected houses in infected holdings suggests that the holding-level prevalence in the United Kingdom would be about 21% higher than the results obtained in the EU survey.

  14. Observations related to the Salmonella EU layer baseline survey in the United Kingdom: follow-up of positive flocks and sensitivity issues

    PubMed Central

    CARRIQUE-MAS, J. J.; BRESLIN, M.; SNOW, L.; ARNOLD, M. E.; WALES, A.; McLAREN, I.; DAVIES, R. H.

    2008-01-01

    SUMMARY A follow-on study was carried out on 23 holdings identified as Salmonella positive in the 2004/2005 European Union (EU) baseline survey of Salmonella in laying hens. Eleven of 13 cage and 4/7 floor houses remained positive for Salmonella when the new flock was tested, and from 10/13 cage and 3/7 floor houses a Salmonella of the same serovar/phage type as found in the EU survey was isolated. There was a high correlation between the level of contamination in the houses at the time of the EU survey and in the follow-on flock. On seven occasions the house identified as positive in the EU survey was sampled after cleaning and disinfection but before a new flock was placed, and in all of them Salmonella could be isolated from the houses. The observed number of infected houses in infected holdings suggests that the holding-level prevalence in the United Kingdom would be about 21% higher than the results obtained in the EU survey. PMID:18177519

  15. Microbiologic evaluation of microfiber mops for surface disinfection.

    PubMed

    Rutala, William A; Gergen, Maria F; Weber, David J

    2007-11-01

    Recently, health care facilities have started to use a microfiber mopping technique rather than a conventional, cotton string mop to clean floors. The effectiveness of microfiber mops to reduce microbial levels on floors was investigated. We compared the efficacy of microfiber mops with that of conventional, cotton string mops in 3 test conditions (cotton mop and standard wringer bucket, microfiber mop and standard wringer bucket, microfiber system). Twenty-four rooms were evaluated for each test condition. RODAC plates containing D/E Neutralizing Agar were used to assess "precleaning" and "postcleaning" microbial levels. The microfiber system demonstrated superior microbial removal compared with cotton string mops when used with a detergent cleaner (95% vs 68%, respectively). The use of a disinfectant did not improve the microbial elimination demonstrated by the microfiber system (95% vs 95%, respectively). However, use of disinfectant did significantly improve microbial removal when a cotton string mop was used (95% vs 68%, respectively). The microfiber system demonstrated superior microbial removal compared with cotton string mops when used with a detergent cleaner. The use of a disinfectant did not improve the microbial elimination demonstrated by the microfiber system.

  16. Evaluation of an Innovative Use of Removable Thin Film Coating Technology for the Abatement of Hazardous Contaminants

    PubMed Central

    Lumia, Margaret E.; Gentile, Charles; Gochfeld, Michael; Efthimion, Philip; Robson, Mark

    2015-01-01

    This study evaluates a new decontamination technique for the mitigation and abatement of hazardous particulates. The traditional decontamination methods used to clean facilities and equipment are time-consuming, prolonging workers' exposure time, may generate airborne hazards, and can be expensive. The use of removable thin film coating as a decontamination technique for surface contamination proved to be a more efficient method of decontamination. This method was tested at three different sites on different hazardous metals. One application of the coating reduced the levels of these metals 90% and had an average reduction of one magnitude. The paired t-tests that were performed for each metal demonstrated that there was a statistically significant reduction of the metal after the use of the coating: lead (p = 0.03), beryllium (p = 0.05), aluminum (p = 0.006), iron (p = 0.0001), and copper (p = 0.004). The Kendall tau-b correlation coefficient demonstrates that there was a positive correlation between the initial levels of contamination and the removal efficiency for all the samples taken from different locations on the floor for each of the three sites. This new decontamination technique worked efficiently, requiring only one application, which decreased exposure time and did not generate any airborne dust. PMID:19437305

  17. Efficacy of low-pressure foam cleaning compared to conventional cleaning methods in the removal of bacteria from surfaces associated with convenience food.

    PubMed

    Lambrechts, A A; Human, I S; Doughari, J H; Lues, J F R

    2014-09-01

    Food borne illnesses and food poisoning are cause for concern globally. The diseases are often caused by food contamination with pathogenic bacteria due largely to poor sanitary habits or storage conditions. Prevalence of some bacteria on cleaned and sanitised food contact surfaces from eight convenience food plants in Gauteng (South Africa) was investigated with the view to evaluate the efficacy of the cleaning methods used with such food contact surfaces. The microbial load of eight convenience food manufacturing plants was determined by sampling stainless steel food contact surfaces after they had been cleaned and sanitised at the end of a day's shift. Samples were analysed for Total Plate Count (TPC), Escherichia coli, Salmonella species, Staphylococcus aureus and Listeria species. Results showed that 59 % of the total areas sampled for TPC failed to comply with the legal requirements for surfaces, according to the Foodstuffs, Cosmetics and Disinfectants Act (< 100 cfu.cm(-2)). S. aureus and Salmonella were not detected, but Listeria was detected in 23 % and E. coli in 1.3 % of the samples. Fifty percent (50 %) of the plants applied conventional cleaning methods for cleaning and sanitation and 50 % used the low-pressure foam (LPF) method. There was significant difference (P ≤ 0.05) between the mean TPC values of the conventional cleaning method (14 358.82) compared to that of LPF method (2 386.51) but no significant difference (P > 0.05) in terms of Listeria species isolates obtained from both cleaning methods. The LPF method proved to be the superior cleaning option for lowering TPC counts. Regardless of cleaning method used, pathogens continued to flourish on various surfaces, including dry stainless steel, posing a contamination hazard for a considerable period depending on the contamination level and type of pathogen. Intensive training for proper chemical usage and strict procedural compliance among workers for efficient cleaning procedures is recommended.

  18. Measurement with verification of stationary signals and noise in extremely quiet environments: Measuring below the noise floor

    PubMed Central

    Ellingson, Roger M.; Gallun, Frederick J.; Bock, Guillaume

    2015-01-01

    It can be problematic to measure stationary acoustic sound pressure level in any environment when the target level approaches or lies below the minimum measureable sound pressure level of the measurement system itself. This minimum measureable level, referred to as the inherent measurement system noise floor, is generally established by noise emission characteristics of measurement system components such as microphones, preamplifiers, and other system circuitry. In this paper, methods are presented and shown accurate measuring stationary levels within 20 dB above and below this system noise floor. Methodology includes (1) measuring inherent measurement system noise, (2) subtractive energy based, inherent noise adjustment of levels affected by system noise floor, and (3) verifying accuracy of inherent noise adjustment technique. While generalizable to other purposes, the techniques presented here were specifically developed to quantify ambient noise levels in very quiet rooms used to evaluate free-field human hearing thresholds. Results obtained applying the methods to objectively measure and verify the ambient noise level in an extremely quiet room, using various measurement system noise floors and analysis bandwidths, are presented and discussed. The verified results demonstrate the adjustment method can accurately extend measurement range to 20 dB below the measurement system noise floor, and how measurement system frequency bandwidth can affect accuracy of reported noise levels. PMID:25786932

  19. Prevention of Salmonella cross-contamination in an oilmeal manufacturing plant.

    PubMed

    Morita, T; Kitazawa, H; Iida, T; Kamata, S

    2006-08-01

    The mechanisms of Salmonella contamination in an oilmeal plant were investigated and the basic data were collected in order to achieve control of Salmonella in oilmeal. Salmonella was detected in all contamination vectors and environmental factors investigated, namely: operators, processing floor, dust in the air and rodents. In particular, high concentrations of Salmonella were detected on the processing floor of the manufacturing area, which has high oil content. Steam was the most effective disinfection method used for the processing floor, as the effects of heat sterilization and disinfection may work in tandem. In addition, restricting the movement of operators of the production chain remarkably reduced Salmonella contamination, even in areas of otherwise high contamination. Within the oilmeal plant, high Salmonella contamination rates for the processing floor represent the greatest risk of contamination of oilmeal via operators, dust in the air and rodents. Therefore, control of the processing floor is the most important means for reducing the oilmeal contamination rate. Specific Salmonella control methods for oilmeal plants have been established.

  20. Manual methods are suboptimal compared with automated methods for cleaning of single-use biopsy forceps.

    PubMed

    Alfa, M J; Nemes, R; Olson, N; Mulaire, A

    2006-08-01

    Most reusable biopsy forceps and all of the currently available single-use biopsy forceps do not have a port that allows fluid flow down the inner tubular shaft of the device. Reusable biopsy forceps are widely used and reprocessed in healthcare facilities, and single-use biopsy forceps are reprocessed either in-house (eg, in Canada and Japan) or by third-party reprocessors (eg, in the United States). The objective of this study was to determine the cleaning efficacy of automated narrow-lumen sonic irrigation cleaning, sonication-only cleaning, and manual cleaning for biopsy forceps. A simulated-use study was performed by inoculating the inner channel of single-use biopsy forceps with artificial test soil containing both Enterococcus faecalis and Geobacillus stearothermophilus at concentrations of 10(6) colony-forming units per milliliter. The cleaning methods evaluated were manual cleaning, sonication-only cleaning, and "retroflush" cleaning by an automated narrow-lumen irrigator. Bioburden and organic soil reduction after washing was evaluated. Forceps used in biopsies of patients were also tested to determine the worst-case soiling levels. Only retroflush irrigation cleaning could effectively remove material from within the shaft portion of the biopsy forceps: it achieved an average reduction of more than 95% in levels of protein, hemoglobin, carbohydrate, and endotoxin. However, even this method of cleaning was not totally effective, as only a 2 log10 reduction in bioburden could be achieved, and there were low residual levels of hemoglobin and carbohydrate. The data from this evaluation indicate that manual and sonication-only cleaning methods for biopsy forceps were totally ineffective in removing material from within the biopsy forceps. Even the use of retroflush cleaning was not totally effective. These findings suggest that in-hospital reprocessing of biopsy forceps with currently available equipment and cleaning methods is suboptimal.

  1. Industrial Technology Modernization Program. Project 44. Modernize Facility Equipment and Processes. Volume 1. Revision 2. Phase 2

    DTIC Science & Technology

    1988-05-01

    OF EXTRUSION HLSGFLN XRSO ICO-F XTUINPPER PATE CUT-OFF EXTRUSION I I 7 TUMBLE S TUMBLE HEAT &SORT TML I IEC SPANK & PIERCE P A SPANK & PIERCEI IF...implementation, the Walnut Cell will utilize 50% of the "As-Is" floor space. 106 -EGREflSEII HSL 59 i.CUT OFF EXTRUSION 2. SPANK & PIERCE I 3.DEGREASE 4...FEMALE MALE CUT-OFF EXTRUSION I HOUSNG HOUNG I SPANK & PIERCE SPANK & PIERCE I CLEAN I DEG SE I I DEGREASEI I C P P E R PL A TE I HEAT TREAT I HEAT

  2. KSC-2009-6673

    NASA Image and Video Library

    2009-12-06

    CAPE CANAVERAL, Fla. - In the Space Station Processing Facility at NASA's Kennedy Space Center in Florida, the newly arrived ExPRESS Logistics Carrier 3, or ELC-3, is lifted high above the clean room floor. ELC-3 and the Alpha Magnetic Spectrometer are the primary payloads for space shuttle Endeavour's STS-134 mission to the International Space Station. The STS-134 crew will also deliver spare parts including two S-band communications antennas, a high pressure gas tank, additional spare parts for Dextre and micrometeoroid debris shields. Endeavour's launch is targeted for July 29, 2010. For information on the STS-134 mission objectives and crew, visit http://www.nasa.gov/shuttle. Photo credit: NASA/Kim Shiflett

  3. Green, Clean, & Mean: Pushing the Energy Envelope in Tech Industry Buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mills, Evan; Granderson, Jessica; Chan, Rengie

    When it comes to innovation in energy and building performance, one can expect leading-edge activity from the technology sector. As front-line innovators in design, materials science, and information management, developing and operating high-performance buildings is a natural extension of their core business. The energy choices made by technology companies have broad importance given their influence on society at large as well as the extent of their own energy footprint. Microsoft, for example, has approximately 250 facilities around the world (30 million square feet of floor area), with significant aggregate energy use of approximately 4 million kilowatt-hours per day (Figure 1).

  4. The Bank of Westminster and Hyland Park Construction Contracts as Engineering Student Classroom Projects; Construction Phase.

    DTIC Science & Technology

    1984-12-13

    8217-- - - -- - - - - - ----- - - - - - - - .101 Clear at Building Clear&Grub @ Bldg. 2000.00 CY .50 1,0(,() Mass Bldg. Excav. 26000.00 CY 2.50 65.00, Grade Beam Excav. 2100.00 CY 4.00...95,112 Sail Investigation Compaction Tests 20.00 EA 150.00 3.000 Perimeter Drainage 2000.00 LF 16.00 32,00 Under Floor Drain LF Clean Walks /Street 1.00 LS...EA4 Equip. Curbs 3500.00 Sf 5.00 17.5:00 -. Grade Beams 7200.00 SF 11.50 82,800 Sumo Pits 1.00 EA 500.00 500 Cooling Tower Sump 600.00 SF 11.50 6,900

  5. Defense Manpower Commission Staff Studies and Supporting Papers. Volume 2. The Total Force and Its Manpower Requirements Including Overviews of Each Service

    DTIC Science & Technology

    1976-05-01

    J^^’.Si*!** \\ ir..’’T^-.’-T*TSfn titoa i iMBi’M, OTTŕ" ,^~" fraCk k^«^;-<^»J,..;^.a,L.^t»^^ri^fc ft WBMyLmH’.’JW*^Hi,.J , Jl,l|llliln|Kli|Pffl...also develop a means to inspect tube internals to insure they are clean 11. Develop a deep tank, high volume, high head hydraulic driven pump to...and procedures that have been implemented at this Command and havs en- hanced productivity are: - Power floor cleaners Pneumatic/ hydraulic ram tire

  6. Schneiderian membrane detachment using transcrestal hydrodynamic ultrasonic cavitational sinus lift: a human cadaver head study and histologic analysis.

    PubMed

    Troedhan, Angelo; Kurrek, Andreas; Wainwright, Marcel; Jank, Siegfried

    2014-08-01

    Recent studies have suggested the osteogenic layer of the periosteum at the base of the sinus membrane to play a key role in bone regeneration after sinus lift procedures. Thus, atraumatic detachment of the sinus membrane with an intact periosteum seems mandatory. The present histologic study of fresh human cadaver heads investigated the detachment behavior and histologic integrity of the detached periosteum after application of the transcrestal hydrodynamic ultrasonic cavitational sinus lift (tHUCSL-INTRALIFT). A total of 15 sinuses in 8 fresh human cadaver heads were treated using tHUCSL-INTRALIFT. After surgery, they were checked macroscopically for damage to the sinus membrane and then processed for histologic inspection under light microscopy. A total of 150 histologic specimens, randomly selected from the core surgical sites, were investigated using hematoxylin-eosin (HE), Azan, and trichrome staining. None of the 150 inspected specimens showed any perforation or dissection of the periosteum from the subepithelial connective tissue and respiratory epithelium and were fully detached from the bony antrum floor. The connecting Sharpey fibers revealed to be cleanly separated from the sinus floor in all specimens. The results of the present study suggest tHUCSL-INTRALIFT should be used to perform predictable and safe detachment of the periosteum from the bony sinus floor as a prerequisite for undisturbed and successful physiologic subantral bone regeneration. Copyright © 2014 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  7. Evaluation of Various Cleaning Methods to Remove Bacillus Spores from Spacecraft Hardware Materials

    NASA Technical Reports Server (NTRS)

    Venkateswaran, Kasthuri; Chung, Shirley; Allton, Judith; Kern, Roger

    2004-01-01

    A detailed study was made of the biological cleaning effectiveness, defined in terms of the ability to remove bacterial spores, of a number of methods used to clean hardware surfaces. Aluminum (Al 6061) and titanium (Ti 6Al-4V) were chosen for the study as they were deemed the two materials most likely to be used in spacecraft extraterrestrial sampler construction. None of the cleaning protocols tested completely removed viable spores from the surface of the aluminum. In contrast, titanium was capable of being cleaned to sterility by two methods, the JPL standard and the commercial SAMS cleaning process. Further investigation showed that the passivation step employed in the JPL standard method is an effective surface sterilant on both metals but not compatible with aluminum. It is recommended that titanium (Ti 6Al-4V) be considered superior to aluminum (Al 6061) for use in spacecraft sampling hardware, both for its potential to be cleaned to sterilization and for its ability to withstand the most effective cleaning protocols.

  8. A TWO-PROBE METHOD FOR MEASURING WATER CONTENT OF THIN FOREST FLOOR LITTER LAYERS USING TIME DOMAIN REFLECTOMETRY

    EPA Science Inventory

    Few methods exist that allow non-destructive in situ measurement of the water content of forest floor litter layers (Oa,Oe, and Oi horizons). Continuous non-destructive measurement is needed in studies of ecosystem processes because of the relationship between physical structure ...

  9. Floor Sensing System Using Laser Reflectivity for Localizing Everyday Objects and Robot

    PubMed Central

    Pyo, Yoonseok; Hasegawa, Tsutomu; Tsuji, Tokuo; Kurazume, Ryo; Morooka, Ken'ichi

    2014-01-01

    This paper describes a new method of measuring the position of everyday objects and a robot on the floor using distance and reflectance acquired by laser range finder (LRF). The information obtained by this method is important for a service robot working in a human daily life environment. Our method uses only one LRF together with a mirror installed on the wall. Moreover, since the area of sensing is limited to a LRF scanning plane parallel to the floor and just a few centimeters above the floor, the scanning covers the whole room with minimal invasion of privacy of a resident, and occlusion problem is mitigated by using mirror. We use the reflection intensity and position information obtained from the target surface. Although it is not possible to identify all objects by additionally using reflection values, it would be easier to identify unknown objects if we can eliminate easily identifiable objects by reflectance. In addition, we propose a method for measuring the robot's pose using the tag which has the encoded reflection pattern optically identified by the LRF. Our experimental results validate the effectiveness of the proposed method. PMID:24763253

  10. Experimental and analytical studies on the vibration serviceability of pre-stressed cable RC truss floor systems

    NASA Astrophysics Data System (ADS)

    Zhou, Xuhong; Cao, Liang; Chen, Y. Frank; Liu, Jiepeng; Li, Jiang

    2016-01-01

    The developed pre-stressed cable reinforced concrete truss (PCT) floor system is a relatively new floor structure, which can be applied to various long-span structures such as buildings, stadiums, and bridges. Due to the lighter mass and longer span, floor vibration would be a serviceability concern problem for such systems. In this paper, field testing and theoretical analysis for the PCT floor system were conducted. Specifically, heel-drop impact and walking tests were performed on the PCT floor system to capture the dynamic properties including natural frequencies, mode shapes, damping ratios, and acceleration response. The PCT floor system was found to be a low frequency (<10 Hz) and low damping (damping ratio<2 percent) structural system. The comparison of the experimental results with the AISC's limiting values indicates that the investigated PCT system exhibits satisfactory vibration perceptibility, however. The analytical solution obtained from the weighted residual method agrees well with the experimental results and thus validates the proposed analytical expression. Sensitivity studies using the analytical solution were also conducted to investigate the vibration performance of the PCT floor system.

  11. Comparative Mirror Cleaning Study: 'A Study on Removing Particulate Contamination'

    NASA Technical Reports Server (NTRS)

    Houston, Karrie

    2007-01-01

    The cleanliness of optical surfaces is recognized as an industry-wide concern for the performance of optical devices such as mirrors and telescopes, microscopes and lenses, lasers and interferometers, and prisms and optical filters. However, no standard has been established for optical cleaning and there is no standard definition of a 'clean' optical element. This study evaluates the effectiveness of commonly used optical cleaning techniques based on wafer configuration, contamination levels, and the number and size of removed particles. It is concluded that cleaning method and exposure time play a significant factor in obtaining a high removal percentage. The detergent bath and solvent rinse method displayed an increase in effective removal percentage as the contamination exposure increased. Likewise, CO2 snow cleaning showed a relatively consistent cleaning effectiveness. The results can help ensure mission success to flight projects developed for the NASA Origins Program. Advantages and disadvantages of each of the optical cleaning methods are described.

  12. The Penn State Safety Floor: Part I--Design parameters associated with walking deflections.

    PubMed

    Casalena, J A; Ovaert, T C; Cavanagh, P R; Streit, D A

    1998-08-01

    A new flooring system has been developed to reduce peak impact forces to the hips when humans fall. The new safety floor is designed to remain relatively rigid under normal walking conditions, but to deform elastically when impacted during a fall. Design objectives included minimizing peak force experienced by the femur during a fall-induced impact, while maintaining a maximum of 2 mm of floor deflection during walking. Finite Element Models (FEMs) were developed to capture the complex dynamics of impact response between two deformable bodies. Validation of the finite element models included analytical calculations of theoretical buckling column response, experimental quasi-static loading of full-scale flooring prototypes, and flooring response during walking trials. Finite Element Method results compared well with theoretical and experimental data. Both finite element and experimental data suggest that the proposed safety floor can effectively meet the design goal of 2 mm maximum deflection during walking, while effectively reducing impact forces during a fall.

  13. An Improved Genetic Fuzzy Logic Control Method to Reduce the Enlargement of Coal Floor Deformation in Shearer Memory Cutting Process

    PubMed Central

    Tan, Chao; Xu, Rongxin; Wang, Zhongbin; Si, Lei; Liu, Xinhua

    2016-01-01

    In order to reduce the enlargement of coal floor deformation and the manual adjustment frequency of rocker arms, an improved approach through integration of improved genetic algorithm and fuzzy logic control (GFLC) method is proposed. The enlargement of coal floor deformation is analyzed and a model is built. Then, the framework of proposed approach is built. Moreover, the constituents of GA such as tangent function roulette wheel selection (Tan-RWS) selection, uniform crossover, and nonuniform mutation are employed to enhance the performance of GFLC. Finally, two simulation examples and an industrial application example are carried out and the results indicate that the proposed method is feasible and efficient. PMID:27217824

  14. Physical and chemical test results of electrostatic safe flooring materials

    NASA Technical Reports Server (NTRS)

    Gompf, R. H.

    1988-01-01

    This test program was initiated because a need existed at the Kennedy Space Center (KSC) to have this information readily available to the engineer who must make the choice of which electrostatic safe floor to use in a specific application. The information, however, should be of value throughout both the government and private industry in the selection of a floor covering material. Included are the test results of 18 floor covering materials which by test evaluation at KSC are considered electrostatically safe. Tests were done and/or the data compiled in the following areas: electrostatics, flammability, hypergolic compatibility, outgassing, floor type, material thickness, and available colors. Each section contains the test method used to gather the data and the test results.

  15. Cleaning procedure for mirror coating at Subaru Telescope

    NASA Astrophysics Data System (ADS)

    Yutani, Masami; Hayashi, Saeko S.; Kurakami, Tomio; Kanzawa, Tomio; Ohshima, Norio; Nakagiri, Masao

    2003-02-01

    We would like to present the procedure of how to prepare the primary mirror of Subaru Telescope for the realuminization. The equipment for the coating and its preparation are located at the ground floor of the telescope enclosure. There are two trolleys for carrying the mirror cell and the mirror itself, a mirror lifting jig, a washing facility for the primary mirror (PMWF), the water purification system, the coating chamber and the waste water pit. The PMWF can provide the tap water for initial rinsing, the chemical for stripping the old coating, and the deionized water for final cleaning. It has two pairs of arms that deploy horizontally above the mirror and have nozzles to spray. The arms spin around its center where the rotary joints are connected to the plumbing from storage tanks. Deck above the water arms serve as platform for personnel for the inspection or for scrubbing work. We use hydrochloric acid mixture to remove the old aluminum coating. For rinsing and final cleaning, we use the water through the purification system. The water supply from the nozzles and the rotation of the arms can be controlled from a panel separated from the washing machine itself. After several experiments and improvements in the washing, we have carried out the coating of the 8.3 m primary mirror in September last year. This was the third time, and the reflectivity of the new coating show satisfactory result.

  16. [Perioperative nursing of internal sinus floor elevation surgery with piezosurgery].

    PubMed

    He, Jing; Lei, Yiling; Wang, Liqiong

    2013-12-01

    This study aims to summarize the nursing experience in the internal sinus floor elevation surgery with piezosurgery. The medical records of 48 patients who underwent sinus floor elevation surgery with piezosurgery in the Department of Implantation, West China Hospital of Stomatology, Sichuan University, were reviewed. The preoperative, intraoperative, and postoperative nursing methods were summarized. All 48 patients underwent smooth surgeries and did not encounter complications. Careful preoperative preparation, careful and meticulous intraoperative nursing cooperation, and provision of sufficient health education after surgery to the patients are the key factors that ensure the success of internal sinus floor elevation surgery with piezosurgery.

  17. Support design and practice for floor heave of deeply buried roadway

    NASA Astrophysics Data System (ADS)

    Liu, Chaoke; Ren, Jianxi; Gao, Bingli; Song, Yongjun

    2017-05-01

    Aiming at the severe floor heave of auxiliary haulage roadway in Jianzhuang Coal Mine, the paper analysed mechanical environment and failure characteristics of auxiliary haulage roadway surrounding rock with the combination of mechanical test, theoretical analysis, industrial test, etc. The mechanical mechanism for deformation and failure of weak rock roadway in Jianzhuang Coal Mine was disclosed by establishing a roadway mechanical model under the effect of even-distributed load, which provided a basis for the design of inverted concrete arch. Based on complex failure mechanism of the roadway, a support method with combined inverted concrete arch and anchor in floor was proposed. The result shows that the ground stress environment has extremely adverse influence on the roadway, and the practice indicates that the floor heave countermeasures can effectively control the floor heave. The obtained conclusion provides a reference for the research and design on control technology of roadway floor heave in the future.

  18. [Urologic examination and treatment of patients with acute injuries of the spinal medulla].

    PubMed

    Jeppesen, L J; Krarup, T; Walter, S; Haase, J

    1989-08-07

    During a period of one year, nine patients with traumatic lesions of the spinal medulla were examined and treated urologically. The patients were followed-up for 24-36 months and follow-up will continue. All of the patients were treated primarily with sterile intermittent catheterization by the nursing staff. Exceptions from this were patients in whom indwelling catheters were necessary on account of complicating conditions. During the acute phase, the patients were examined by a urologist and bladder function investigations with cystometry + electromyographic registration from the pelvic floor were undertaken. When patients had recovered from the spinal shock phase, emptying of the bladder supplemented by alpha-adrenergic blocking preparations and clean intermittent catheterization were instituted in the patients with supra-sacral lesions. Patients with infra-sacral bladder paresis were trained in miction on abdominal pressure supplemented by clean intermittent catheterization. No complications from this treatment have occurred and renal function has remained stable. Only one patient has an indwelling catheter and it has not proved possible to persuade the patient to accept removal.

  19. Use of enzymatic cleaners on US Navy ships. Research report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Venkatachalam, R.S.

    1996-03-01

    The Naval Surface Warfare Center, Carderock Division, conducted a study to determine the feasibility of using enzymatic and bacterial products in cleaning applications aboard U.S. Navy ships. A review of the most recent technical literature and a survey of potential suppliers were conducted. In addition, shipboard systems, subsystems and housekeeping processes were evaluated to identify suitable applications for enzymatic and bacterial cleaners. The study identified numerous commercial products that, based on manufacturers` claims, would be effective and safe for use aboard ship to clean walls, floors, galley work surfaces, engine and machine parts, drains, pipes, grease traps, collection, holding andmore » transfer (CHT) tanks, ballast tanks and bilge areas. However, the study also revealed the absence of standardized test protocols essential for validation of manufacturers` claims, and recommended the cooperative development of such protocols by representatives from the commercial sector, Government and academia. The need to obtain meaningful cost information based on actual use scenarios and to investigate any permitting issues associated with the discharge of related wastes to pierside facilities was also identified.« less

  20. Validation of Mobility of Pedestrians with Low Vision Using Graphic Floor Signs and Voice Guides.

    PubMed

    Omori, Kiyohiro; Yanagihara, Takao; Kitagawa, Hiroshi; Ikeda, Norihiro

    2015-01-01

    Some people with low vision or elderly persons tend to walk while watching a nearby floor, therefore, they often overlook or hard to read suspended signs. In this study, we propose two kinds of voice guides, and an experiment is conducted by participants with low vision using these voice guides and graphic floor signs in order to investigate effectiveness of these combinations. In clock position method (CP), each direction of near facilities are described in using an analogy of a 12-hour clock. Meanwhile, in numbering method (NU), near facilities are put the number in clockwise order, however, each direction are only illustrated in a crossing sign. As a result of an experiment, it is showed that both voice guides are effective for pedestrians with low vision. NU is used as a complement of graphic floor signs. Meanwhile, CP is used independently with graphic floor signs, however, there is a risk in the case of using in the environment where pedestrians are easy to mistake the reference direction defined by the sounding speaker.

  1. Method for removal of beryllium contamination from an article

    DOEpatents

    Simandl, Ronald F.; Hollenbeck, Scott M.

    2012-12-25

    A method of removal of beryllium contamination from an article is disclosed. The method typically involves dissolving polyisobutylene in a solvent such as hexane to form a tackifier solution, soaking the substrate in the tackifier to produce a preform, and then drying the preform to produce the cleaning medium. The cleaning media are typically used dry, without any liquid cleaning agent to rub the surface of the article and remove the beryllium contamination below a non-detect level. In some embodiments no detectible residue is transferred from the cleaning wipe to the article as a result of the cleaning process.

  2. Pilot cluster randomised controlled trial of flooring to reduce injuries from falls in elderly care units: study protocol.

    PubMed

    Drahota, Amy; Gal, Diane; Windsor, Julie; Dixon, Simon; Udell, Julie; Ward, Derek; Soilemezi, Dia; Dean, Taraneh; Severs, Martin

    2011-12-01

    Falls are an issue disproportionately affecting older people who are at increased risk of falls and injury. This protocol describes a pilot study investigating shock-absorbing flooring for fall-related injuries in wards for older people. To inform future research by evaluating fall-related injuries on the intervention and existing flooring, assessing the sustainability of the flooring in ward environments, estimating the cost-effectiveness of the floor and assessing how the floor affects patients and other users. This study uses mixed methods a pilot cluster randomised controlled trial, observation via mechanical testing and interviews. Eight participating wards (clusters) are randomised using a computer-generated list. No blinding is incorporated into the study. Each site has a baseline period of approximately 6 months. Then, four sites receive the intervention floor, while four continue using standard floors. Sites are then followed up for approximately 1 year. Any person admitted to a bed in the 'study area' of a participating ward can be entered into the trial. Orientated patients, visitors and any hospital staff who use the floor in a study area are eligible for inclusion in an interview. An 8.3 mm thick vinyl floor covering with polyvinyl chloride foam backing (Tarkett Omnisports EXCEL). The primary outcome is fall-related injuries. Severity of injuries, falls, cost-effectiveness, user views and mechanical performance (shock absorbency and slip resistance) are also being assessed.

  3. Infrastructure and Contamination of the Physical Environment in Three Bangladeshi Hospitals: Putting Infection Control into Context

    PubMed Central

    Rimi, Nadia Ali; Sultana, Rebeca; Luby, Stephen P.; Islam, Mohammed Saiful; Uddin, Main; Hossain, Mohammad Jahangir; Zaman, Rashid Uz; Nahar, Nazmun; Gurley, Emily S.

    2014-01-01

    Objective This paper describes the physical structure and environmental contamination in selected hospital wards in three government hospitals in Bangladesh. Methods The qualitative research team conducted 48 hours of observation in six wards from three Bangladeshi tertiary hospitals in 2007. They recorded environmental contamination with body secretions and excretions and medical waste and observed ward occupant handwashing and use of personal protective equipment. They recorded number of persons, number of open doors and windows, and use of fans. They measured the ward area and informally observed waste disposal outside the wards. They conducted nine focus group discussions with doctors, nurses and support staff. Results A median of 3.7 persons were present per 10 m2 of floor space in the wards. A median of 4.9 uncovered coughs or sneezes were recorded per 10 m2 per hour per ward. Floors in the wards were soiled with saliva, spit, mucous, vomitus, feces and blood 125 times in 48 hours. Only two of the 12 patient handwashing stations had running water and none had soap. No disinfection was observed before or after using medical instruments. Used medical supplies were often discarded in open containers under the beds. Handwashing with soap was observed in only 32 of 3,373 handwashing opportunities noted during 48 hours. Mosquitoes and feral cats were commonly observed in the wards. Conclusions The physical structure and environment of our study hospitals are conducive to the spread of infection to people in the wards. Low-cost interventions on hand hygiene and cleaning procedures for rooms and medical equipment should be developed and evaluated for their practicality and effectiveness. PMID:24586516

  4. Influence of adequate pelvic floor muscle contraction on the movement of the coccyx during pelvic floor muscle training.

    PubMed

    Fujisaki, Akiko; Shigeta, Miwa; Shimoinaba, Misa; Yoshimura, Yasukuni

    2018-04-01

    [Purpose] Pelvic floor muscle training is a first-line therapy for female stress urinary incontinence. Previous studies have suggested that the coccyx tip moves ventrally and cranially during pelvic floor muscle contraction. The study aimed to elucidate the influence of adequate pelvic floor muscle contraction on coccyx movement. [Subjects and Methods] Sixty-three females (57 patients with stress urinary incontinence and additional 6 healthy volunteers) were enrolled. Using magnetic resonance imaging, coccyx movement was evaluated during pelvic floor muscle contraction and strain. An adequate contraction was defined as a contraction with good Oxford grading scale [≥3] and without inadequate muscle substitution patterns. [Results] Inadequate muscle substitution patterns were observed in 33 participants (52.4%). No significant difference was observed in the movement of the coccyx tip in the ventrodorsal direction between females with and without inadequate muscle substitution patterns. However, a significant increase in the movement of the coccyx tip in the cranial direction was detected in the group without inadequate muscle substitution patterns. Compared to participants with inadequate pelvic floor muscle contraction, those who had adequate pelvic floor muscle contraction exhibited significantly increased cranial movement of the coccyx. [Conclusion] Adequate pelvic floor muscle contraction can produce cranial movement of the coccyx tip.

  5. Comparison of methods to control floor contamination in an animal research facility.

    PubMed

    Allen, Kenneth P; Csida, Tarrant; Leming, Jeaninne; Murray, Kathleen; Gauld, Stephen B; Thulin, Joseph

    2012-10-01

    The authors evaluated the effectiveness of adhesive mats, contamination control flooring, and shoe covers in decreasing the presence of microbial agents on animal holding room floors and footwear. Swab samples taken from animal holding room floors after the use of each product were compared with samples taken from rooms after no products were used. Swab samples were also taken from the heels and soles of the footwear of animal care staff before and after use of each product. The use of contamination control flooring or shoe covers significantly reduced the amount of organic material (as indicated by ATP levels measured by a luminometer) present on floors. Bacterial and ATP contamination of footwear was significantly lower after the use of shoe covers than after the use of adhesive mats or contamination control flooring, and the use of shoe covers led to a greater decrease in contamination before and after use than did use of either of the other two products. Although shoe covers were superior to both adhesive mats and contamination control flooring for decreasing contamination of animal room floors and footwear, facilities must take into account the contamination control standards required, the cost of the product, and the labor and time associated with product use when deciding which contamination control practices to implement.

  6. Cleaning method and apparatus

    DOEpatents

    Jackson, D.D.; Hollen, R.M.

    1981-02-27

    A method of very thoroughly and quikcly cleaning a guaze electrode used in chemical analyses is given, as well as an automobile cleaning apparatus which makes use of the method. The method generates very little waste solution, and this is very important in analyzing radioactive materials, especially in aqueous solutions. The cleaning apparatus can be used in a larger, fully automated controlled potential coulometric apparatus. About 99.98% of a 5 mg plutonium sample was removed in less than 3 minutes, using only about 60 ml of rinse solution and two main rinse steps.

  7. [Awareness of the methods of primary and secondary childbirth trauma prevention among parturients].

    PubMed

    Veverková, A; Kališ, V; Rušavý, Z

    2017-01-01

    To evaluate the awareness of fresh mothers regarding the primary prevention of pelvic floor disorders after childbirth. The secondary objective was to identify sources of information, reality of childbirth trauma prevention and attitude to pelvic floor muscle training. Prospective survey study. Department of Gynecology and Obstetrics, University Hospital and Medical Faculty in Pilsen, Charles University. We included 202 women after a vaginal delivery at our center from 6/2015 to 12/2015. These women completed anonymous questionnaire with six questions. 83% of respondents were informed regarding the possibility of primary prevention of childbirth, nulliparas were informed better (88%). The main source of information was the Internet (46%), while only 5% of women received information from their doctor. Despite the high awareness of postpartum trauma prevention, less than half of interviewed women actually performed it (35%). The most widely used method was the massage of the perineum (29%), vaginal dilatation balloons were used less (7%) and alternative methods were pursued by only 4% of women. Experience with pelvic floor muscle exercises had 79% of women, while 90% wanted to exercise after the delivery. Awareness of mothers regarding primary and secondary prevention of pelvic floor disorders is satisfactory. Nevertheless, the information from doctors is inadequate. Despite high awareness, the antepartum prevention methods are used relatively rarely. The study clearly shows the level of awareness and reality of primary and secondary prevention of pelvic floor disorders in our region.

  8. Knowledge of the pelvic floor in nulliparous women

    PubMed Central

    Neels, Hedwig; Wyndaele, Jean-Jacques; Tjalma, Wiebren A. A.; De Wachter, Stefan; Wyndaele, Michel; Vermandel, Alexandra

    2016-01-01

    [Purpose] Proper pelvic floor function is important to avoid serious dysfunctions including incontinence, prolapse, and sexual problems. The current study evaluated the knowledge of young nulliparous women about their pelvic floor and identified what additional information they wanted. [Subjects and Methods] In this cross-sectional survey, a validated, 36 item questionnaire was distributed to 212 nulliparous women. The questionnaire addressed demography, pelvic floor muscles, pelvic floor dysfunction, and possible information sources. Descriptive statistics were generated for all variables. Stability and validity testing were performed using Kappa statistics and intra class correlation coefficients to define agreement for each question. The study was approved by the ethics Committee (B300201318334). [Results] Using a VAS scale (0 to 10), the women rated their knowledge about the pelvic floor as a mean of 2.4 (SD 2.01). A total of 93% of the women were insufficiently informed and requested more information; 25% had concerns about developing urinary incontinence, and 14% about fecal incontinence. Many of the women were unaware what pelvic floor training meant. [Conclusion] There was a significant lack of knowledge about pelvic floor function among nulliparous women. The majority of nulliparous women expressed a need for education, which might offer a way to reduce dysfunction. PMID:27313364

  9. Temperature control of thermal-gas-dynamical installation in cleaning oil-well tubes

    NASA Astrophysics Data System (ADS)

    Penner, V. A.; Martemyanov, D. B.; Pshenichnikova, V. V.

    2017-08-01

    The article provides the study results of cleaning oil-well tubes, the oil-well tube failure reasons for service by their types have been considered. The chemical method of cleaning oil-well tubes as the least expensive has been reviewed when acid solution moves to the interptube space mixing up with oil and liquidates paraffin and pitches deposits on the internal pipe surface. Except the chemical method of pipes cleaning the mechanical one was considered as well. Also the disadvantages -such as the low productivity of cleaning and design complexity- of this deposits removal method on the internal oil-well tube surface have been considered. An effective method for cleaning oil-well tubing from paraffin and pitches by the thermodynamic plant based on the aircraft engine has been introduced for the first time. The temperature distribution graph in the gas stream at the engine output has been given.

  10. Complications of orbital floor repair with silastic sheet: the skin fistula.

    PubMed

    Aboh, Ikenna Valentine; Chisci, Glauco; Gennaro, Paolo; Giovannetti, Filippo; Bartoli, Davina; Priore, Paolo; Anelli, Andrea; Iannetti, Giorgio

    2013-07-01

    Treatment of orbital floor fracture is a subject of great interest in maxillofacial surgery. Many materials have been described for its reconstruction.In this article, the authors report a case of a patient who, 7 years from a previous orbital floor fracture and treatment with silastic sheet, presented herself to their clinic for the failure of the material used for its reconstruction and a skin fistula.Orbital floor repair with silastic sheet is an old method that no one uses anymore, but we still observe cases of late complications with this material. So a fine knowledge of silastic sheet complications is needed for young surgeons.The authors report the case and perform a literature review about the use of more modern biomaterials for orbital floor reconstruction.

  11. Towards sustainable and safe apparel cleaning methods: A review.

    PubMed

    Troynikov, Olga; Watson, Christopher; Jadhav, Amit; Nawaz, Nazia; Kettlewell, Roy

    2016-11-01

    Perchloroethylene (PERC) is a compound commonly used as a solvent in dry cleaning, despite its severe health and environmental impacts. In recent times chemicals such as hydrocarbons, GreenEarth(®), acetal and liquid carbon dioxide have emerged as less damaging substitutes for PERC, and an even more sustainable water-based wet cleaning process has been developed. We employed a systematic review approach to provide a comprehensive overview of the existing research evidence in the area of sustainable and safe apparel cleaning methods and care. Our review describes traditional professional dry cleaning methods, as well as those that utilise solvents other than PERC, and their ecological attributes. In addition, the new professional wet cleaning process is discussed. Finally, we address the health hazards of the various solvents used in dry cleaning and state-of-the-art solvent residue trace analysis techniques. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Air powder abrasive treatment as an implant surface cleaning method: a literature review.

    PubMed

    Tastepe, Ceylin S; van Waas, Rien; Liu, Yuelian; Wismeijer, Daniel

    2012-01-01

    To evaluate the air powder abrasive treatment as an implant surface cleaning method for peri-implantitis based on the existing literature. A PubMed search was conducted to find articles that reported on air powder abrasive treatment as an implant surface cleaning method for peri-implantitis. The studies evaluated cleaning efficiency and surface change as a result of the method. Furthermore, cell response toward the air powder abrasive-treated discs, reosseointegration, and clinical outcome after treatment is also reported. The PubMed search resulted in 27 articles meeting the inclusion criteria. In vitro cleaning efficiency of the method is reported to be high. The method resulted in minor surface changes on titanium specimens. Although the air powder abrasive-treated specimens showed sufficient levels of cell attachment and cell viability, the cell response decreased compared with sterile discs. Considerable reosseointegration between 39% and 46% and improved clinical parameters were reported after treatment when applied in combination with surgical treatment. The results of the treatment are influenced by the powder type used, the application time, and whether powder was applied surgically or nonsurgically. The in vivo data on air powder abrasive treatment as an implant surface cleaning method is not sufficient to draw definitive conclusions. However, in vitro results allow the clinician to consider the method as a promising option for implant surface cleaning in peri-implantitis treatment.

  13. Characterization of occupational exposures to cleaning products used for common cleaning tasks-a pilot study of hospital cleaners

    PubMed Central

    2009-01-01

    Background In recent years, cleaning has been identified as an occupational risk because of an increased incidence of reported respiratory effects, such as asthma and asthma-like symptoms among cleaning workers. Due to the lack of systematic occupational hygiene analyses and workplace exposure data, it is not clear which cleaning-related exposures induce or aggravate asthma and other respiratory effects. Currently, there is a need for systematic evaluation of cleaning products ingredients and their exposures in the workplace. The objectives of this work were to: a) identify cleaning products' ingredients of concern with respect to respiratory and skin irritation and sensitization; and b) assess the potential for inhalation and dermal exposures to these ingredients during common cleaning tasks. Methods We prioritized ingredients of concern in cleaning products commonly used in several hospitals in Massachusetts. Methods included workplace interviews, reviews of product Materials Safety Data Sheets and the scientific literature on adverse health effects to humans, reviews of physico-chemical properties of cleaning ingredients, and occupational hygiene observational analyses. Furthermore, the potential for exposure in the workplace was assessed by conducting qualitative assessment of airborne exposures and semi-quantitative assessment of dermal exposures. Results Cleaning products used for common cleaning tasks were mixtures of many chemicals, including respiratory and dermal irritants and sensitizers. Examples of ingredients of concern include quaternary ammonium compounds, 2-butoxyethanol, and ethanolamines. Cleaning workers are at risk of acute and chronic inhalation exposures to volatile organic compounds (VOC) vapors and aerosols generated from product spraying, and dermal exposures mostly through hands. Conclusion Cleaning products are mixtures of many chemical ingredients that may impact workers' health through air and dermal exposures. Because cleaning exposures are a function of product formulations and product application procedures, a combination of product evaluation with workplace exposure assessment is critical in developing strategies for protecting workers from cleaning hazards. Our task based assessment methods allowed classification of tasks in different exposure categories, a strategy that can be employed by epidemiological investigations related to cleaning. The methods presented here can be used by occupational and environmental health practitioners to identify intervention strategies. PMID:19327131

  14. Prediction on the Enhancement of the Impact Sound Insulation to a Floating Floor with Resilient Interlayer

    NASA Astrophysics Data System (ADS)

    Huang, Xianfeng; Meng, Yao; Huang, Riming

    2017-10-01

    This paper describes a theoretical method for predicting the improvement of the impact sound insulation to a floating floor with the resilient interlayer. Statistical energy analysis (SEA) model, which is skilful in calculating the floor impact sound, is set up for calculating the reduction in impact sound pressure level in downstairs room. The sound transmission paths which include direct path and flanking paths are analyzed to find the dominant one; the factors that affect impact sound reduction for a floating floor are explored. Then, the impact sound level in downstairs room is determined and comparisons between predicted and measured data are conducted. It is indicated that for the impact sound transmission across a floating floor, the flanking path impact sound level contribute tiny influence on overall sound level in downstairs room, and a floating floor with low stiffness interlayer exhibits favorable sound insulation on direct path. The SEA approach applies to the floating floors with resilient interlayers, which are experimentally verified, provides a guidance in sound insulation design.

  15. Evaluation of the hygienogram scores and related data obtained after cleaning and disinfection of poultry houses in Flanders during the period 2007 to 2014.

    PubMed

    Maertens, H; De Reu, K; Van Weyenberg, S; Van Coillie, E; Meyer, E; Van Meirhaeghe, H; Van Immerseel, F; Vandenbroucke, V; Vanrobaeys, M; Dewulf, J

    2018-02-01

    Cleaning and disinfection (C&D) of poultry houses is an essential aspect in farm hygiene management. Adequate performance of the different steps of a C&D protocol and the use of suitable products are key to prevent and control zoonoses and animal diseases. Hygiene monitoring on total aerobic flora through sampling with agar contact plates at different locations of the poultry house results in a hygienogram score that is used to evaluate the proper execution of C&D.This study analyzed the hygienogram scores of 19,739 poultry flocks in Flanders after C&D. Data relating to the C&D protocol, i.e., year, season, husbandry system, production type, cleaning product, sampler, active components of the disinfectant, disinfection time, disinfection temperature, and disinfection responsible, were collected.The average hygienogram score decreased significantly over time, suggesting a general improvement between 2007 and 2014. Differences in scores were found among the husbandry systems, with the barn/aviary system having a significantly better hygienogram score compared to the floor house, furnished cage, and battery. Significantly better scores also were found when a cleaning product was used in the C&D protocol. Disinfection with a peracetic acid and hydrogen peroxide combination or formaldehyde gave the best scores. In addition, C&D protocols using ≥2 different disinfectants showed improved results compared to the use of one single disinfectant. Finally, disinfection applied by a specialist contractor resulted in a better score compared to disinfection by the farmer.In conclusion, analysis of the hygienogram scores and related data allowed identifying several factors, resulting in an improvement, which may reduce the total bacterial load in poultry stables and, consequently, the number of zoonotic and pathogenic micro-organisms. © 2017 Poultry Science Association Inc.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Regnier, Cindy; Harding, Ari; Robinson, Alastair

    The University of Hawai’i at Mānoa (UHM) partnered with the US Department of Energy (DOE) and the Hawai`i Clean Energy Initiative to develop and implement solutions to retrofit exiting buildings to reduce energy consumption by at least 30% as part of DOE’s Commercial Building Partnerships (CBP) Program1. Kuykendall Hall, located on the UHM campus in Honolulu, was the focus of a CBP analysis and design collaboration among the University of Hawai’i, their consultants, and Lawrence Berkeley National Laboratory (LBNL). Kuykendall Hall consists of two 1960s-era wings – a four-story wing containing classrooms, and a seven-story tower containing offices – withmore » a total floor area of approximately 76,000 square feet (ft²).« less

  17. Clean access, measurement, and sampling of Ellsworth Subglacial Lake: A method for exploring deep Antarctic subglacial lake environments

    NASA Astrophysics Data System (ADS)

    Siegert, Martin J.; Clarke, Rachel J.; Mowlem, Matt; Ross, Neil; Hill, Christopher S.; Tait, Andrew; Hodgson, Dominic; Parnell, John; Tranter, Martyn; Pearce, David; Bentley, Michael J.; Cockell, Charles; Tsaloglou, Maria-Nefeli; Smith, Andy; Woodward, John; Brito, Mario P.; Waugh, Ed

    2012-01-01

    Antarctic subglacial lakes are thought to be extreme habitats for microbial life and may contain important records of ice sheet history and climate change within their lake floor sediments. To find whether or not this is true, and to answer the science questions that would follow, direct measurement and sampling of these environments are required. Ever since the water depth of Vostok Subglacial Lake was shown to be >500 m, attention has been given to how these unique, ancient, and pristine environments may be entered without contamination and adverse disturbance. Several organizations have offered guidelines on the desirable cleanliness and sterility requirements for direct sampling experiments, including the U.S. National Academy of Sciences and the Scientific Committee on Antarctic Research. Here we summarize the scientific protocols and methods being developed for the exploration of Ellsworth Subglacial Lake in West Antarctica, planned for 2012-2013, which we offer as a guide to future subglacial environment research missions. The proposed exploration involves accessing the lake using a hot-water drill and deploying a sampling probe and sediment corer to allow sample collection. We focus here on how this can be undertaken with minimal environmental impact while maximizing scientific return without compromising the environment for future experiments.

  18. Cleaning method and apparatus

    DOEpatents

    Jackson, Darryl D.; Hollen, Robert M.

    1983-01-01

    A new automatable cleaning apparatus which makes use of a method of very thoroughly and quickly cleaning a gauze electrode used in chemical analyses is given. The method generates very little waste solution, and this is very important in analyzing radioactive materials, especially in aqueous solutions. The cleaning apparatus can be used in a larger, fully automated controlled potential coulometric apparatus. About 99.98% of a 5 mg. plutonium sample was removed in less than 3 minutes, using only about 60 ml. of rinse solution and two main rinse steps.

  19. CTEPP STANDARD OPERATING PROCEDURE FOR PRE-CLEANING FILTERS AND XAD-2 (SOP-5.10)

    EPA Science Inventory

    This SOP summarizes the method for pre-cleaning XAD-2 resin and quartz fiber filters. The procedure provides a cleaning method to help reduce potential background contamination in the resin and filters.

  20. Pediatric falls from windows and balconies: incidents and risk factors as reported by newspapers in the United Arab Emirates.

    PubMed

    Grivna, Michal; Al-Marzouqi, Hanan M; Al-Ali, Maryam R; Al-Saadi, Nada N; Abu-Zidan, Fikri M

    2017-01-01

    Falls of children from heights (balconies and windows) usually result in severe injuries and death. Details on child falls from heights in the United Arab Emirates (UAE) are not easily accessible. Our aim was to assess the incidents, personal, and environmental risk factors for pediatric falls from windows/balconies using newspaper clippings. We used a retrospective study design to electronically assess all major UAE national Arabic and English newspapers for reports of unintentional child falls from windows and balconies during 2005-2016. A structured data collection form was developed to collect information. Data were entered into an Excel sheet and descriptive analysis was performed. Newspaper clippings documented 96 fall incidents. After cleaning the data and excluding duplicate cases and intentional injuries, 81 cases were included into the final analysis. Fifty-three percent ( n  = 42) were boys. The mean (range) age was 4.9 years (1-15). Thirty-eight (47%) children fell from windows and 36 (44%) from balconies. Twenty-two (27%) children climbed on the furniture placed on a balcony or close to a window. Twenty-five (31%) children were not alone in the apartment when they fell. Twenty-nine children fell from less than 5 floors (37%), 33 from 5 to 10 floors (42%) and 16 from more than 10 floors (21%) . Fifteen children (19%) were hospitalized and survived the fall incident, while 66 died (81%). Newspapers proved to be useful to study pediatric falls from heights. It is necessary to improve window safety by installing window guards and raising awareness.

  1. A strong pelvic floor is associated with higher rates of sexual activity in women with pelvic floor disorders

    PubMed Central

    Kanter, Gregg; Rogers, Rebecca G; Pauls, Rachel N; Kammerer-Doak, Dorothy; Thakar, Ranee

    2015-01-01

    Introduction and Hypothesis We evaluated the associations between pelvic floor muscle strength and tone with sexual activity and sexual function in women with pelvic floor disorders. Methods This was a secondary analysis of a multicenter study of women with pelvic floor disorders from the US and UK performed to validate the Pelvic Organ Prolapse/Incontinence Sexual Questionnaire, IUGA-Revised (PISQ-IR). Participants were surveyed about whether they were sexually active and completed the PISQ-IR and Female Sexual Function Index (FSFI) questionnaires to assess sexual function. Physical exams included assessment of pelvic floor strength by the Oxford Grading Scale, and assessment of pelvic floor tone per ICS guidelines. Results The cohort of 585 women was middle aged (mean age 54.9 +/−12.1) with 395 (67.5%) reporting sexual activity. Women with a strong pelvic floor (n=275) were more likely to report sexual activity than women with weak strength (n=280) (75.3 vs. 61.8%, p<0.001), but normal or hypoactive pelvic floor tone was not associated with sexual activity (68.8 vs. 60.2%, normal vs. hypoactive, p=0.08). After multivariable analysis, a strong pelvic floor remained predictive of sexual activity (OR 1.89, CI 1.18–3.03, p<0.01). Among sexually active women (n=370), a strong pelvic floor was associated with higher scores on the PISQ-IR domain of condition impact (Parameter Estimate 0.20+/−0.09, P=0.04), and FSFI orgasm domain (PE 0.51+/−0.17, P=0.004). Conclusion A strong pelvic floor is associated with higher rates of sexual activity as well as higher sexual function scores on the condition impact domain of the PISQ-IR and orgasm domain of the FSFI. PMID:25994625

  2. Physical and cultural determinants of postpartum pelvic floor support and symptoms following vaginal delivery: a protocol for a mixed-methods prospective cohort study.

    PubMed

    Nygaard, Ingrid E; Clark, Erin; Clark, Lauren; Egger, Marlene J; Hitchcock, Robert; Hsu, Yvonne; Norton, Peggy; Sanchez-Birkhead, Ana; Shaw, Janet; Sheng, Xiaoming; Varner, Michael

    2017-01-10

    Pelvic floor disorders (PFDs), including pelvic organ prolapse (POP), stress and urgency urinary incontinence, and faecal incontinence, are common and arise from loss of pelvic support. Although severe disease often does not occur until women become older, pregnancy and childbirth are major risk factors for PFDs, especially POP. We understand little about modifiable factors that impact pelvic floor function recovery after vaginal birth. This National Institutes of Health (NIH)-funded Program Project, 'Bridging physical and cultural determinants of postpartum pelvic floor support and symptoms following vaginal delivery', uses mixed-methods research to study the influences of intra-abdominal pressure, physical activity, body habitus and muscle fitness on pelvic floor support and symptoms as well as the cultural context in which women experience those changes. Using quantitative methods, we will evaluate whether pelvic floor support and symptoms 1 year after the first vaginal delivery are affected by biologically plausible factors that may impact muscle, nerve and connective tissue healing during recovery (first 8 weeks postpartum) and strengthening (remainder of the first postpartum year). Using qualitative methods, we will examine cultural aspects of perceptions, explanations of changes in pelvic floor support, and actions taken by Mexican-American and Euro-American primipara, emphasising early changes after childbirth. We will summarise project results in a resource toolkit that will enhance opportunities for dialogue between women, their families and providers, and across lay and medical discourses. We anticipate enrolling up to 1530 nulliparous women into the prospective cohort study during the third trimester, following those who deliver vaginally 1 year postpartum. Participants will be drawn from this cohort to meet the project's aims. The University of Utah and Intermountain Healthcare Institutional Review Boards approved this study. Data are stored in a secure password-protected database. Papers summarising the primary results and ancillary analyses will be published in peer-reviewed journals. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  3. Evaluation of various cleaning methods to remove bacillus spores from spacecraft hardware materials

    NASA Technical Reports Server (NTRS)

    Venkateswaran, Kasthuri; Chung, Shirley; Allton, Judith; Kern, Roger

    2004-01-01

    A detailed study was made of the biological cleaning effectiveness, defined in terms of the ability to remove bacterial spores, of a number of methods used to clean hardware surfaces. Aluminum (Al 6061) and titanium (Ti 6Al-4V) were chosen for the study as they were deemed the two materials most likely to be used in spacecraft extraterrestrial sampler construction. Metal coupons (1 cm x 2.5 cm) were precleaned and inoculated with 5.8 x 10(3) cultivable Bacillus subtilis spores, which are commonly found on spacecraft surfaces and in the assembly environments. The inoculated coupons were subsequently cleaned using: (1) 70% isopropyl alcohol wipe; (2) water wipe; (3) multiple-solvent flight-hardware cleaning procedures used at the Jet Propulsion Laboratory (JPL); (4) Johnson Space Center-developed ultrapure water rinse; and (5) a commercial, semi-aqueous, multiple-solvent (SAMS) cleaning process. The biological cleaning effectiveness was measured by agar plate assay, sterility test (growing in liquid media), and epifluorescent microscopy. None of the cleaning protocols tested completely removed viable spores from the surface of the aluminum. In contrast, titanium was capable of being cleaned to sterility by two methods, the JPL standard and the commercial SAMS cleaning process. Further investigation showed that the passivation step employed in the JPL standard method is an effective surface sterilant on both metals but not compatible with aluminum. It is recommended that titanium (Ti 6Al-4V) be considered superior to aluminum (Al 6061) for use in spacecraft sampling hardware, both for its potential to be cleaned to sterilization and for its ability to withstand the most effective cleaning protocols.

  4. Evaluation of Various Cleaning Methods to Remove Bacillus Spores from Spacecraft Hardware Materials

    NASA Astrophysics Data System (ADS)

    Venkateswaran, Kasthuri; Chung, Shirley; Allton, Judith; Kern, Roger

    2004-09-01

    A detailed study was made of the biological cleaning effectiveness, defined in terms of the ability to remove bacterial spores, of a number of methods used to clean hardware surfaces. Aluminum (Al 6061) and titanium (Ti 6Al-4V) were chosen for the study as they were deemed the two materials most likely to be used in spacecraft extraterrestrial sampler construction. Metal coupons (1 cm × 2.5 cm) were precleaned and inoculated with 5.8 × 103 cultivable Bacillus subtilis spores, which are commonly found on spacecraft surfaces and in the assembly environments. The inoculated coupons were subsequently cleaned using: (1) 70% isopropyl alcohol wipe; (2) water wipe; (3) multiple-solvent flight-hardware cleaning procedures used at the Jet Propulsion Laboratory (JPL); (4) Johnson Space Center-developed ultrapure water rinse; and (5) a commercial, semi-aqueous, multiple-solvent (SAMS) cleaning process. The biological cleaning effectiveness was measured by agar plate assay, sterility test (growing in liquid media), and epifluorescent microscopy. None of the cleaning protocols tested completely removed viable spores from the surface of the aluminum. In contrast, titanium was capable of being cleaned to sterility by two methods, the JPL standard and the commercial SAMS cleaning process. Further investigation showed that the passivation step employed in the JPL standard method is an effective surface sterilant on both metals but not compatible with aluminum. It is recommended that titanium (Ti 6Al-4V) be considered superior to aluminum (Al 6061) for use in spacecraft sampling hardware, both for its potential to be cleaned to sterilization and for its ability to withstand the most effective cleaning protocols.

  5. Evaluation of various cleaning methods to remove bacillus spores from spacecraft hardware materials.

    PubMed

    Venkateswaran, Kasthuri; Chung, Shirley; Allton, Judith; Kern, Roger

    2004-01-01

    A detailed study was made of the biological cleaning effectiveness, defined in terms of the ability to remove bacterial spores, of a number of methods used to clean hardware surfaces. Aluminum (Al 6061) and titanium (Ti 6Al-4V) were chosen for the study as they were deemed the two materials most likely to be used in spacecraft extraterrestrial sampler construction. Metal coupons (1 cm x 2.5 cm) were precleaned and inoculated with 5.8 x 10(3) cultivable Bacillus subtilis spores, which are commonly found on spacecraft surfaces and in the assembly environments. The inoculated coupons were subsequently cleaned using: (1) 70% isopropyl alcohol wipe; (2) water wipe; (3) multiple-solvent flight-hardware cleaning procedures used at the Jet Propulsion Laboratory (JPL); (4) Johnson Space Center-developed ultrapure water rinse; and (5) a commercial, semi-aqueous, multiple-solvent (SAMS) cleaning process. The biological cleaning effectiveness was measured by agar plate assay, sterility test (growing in liquid media), and epifluorescent microscopy. None of the cleaning protocols tested completely removed viable spores from the surface of the aluminum. In contrast, titanium was capable of being cleaned to sterility by two methods, the JPL standard and the commercial SAMS cleaning process. Further investigation showed that the passivation step employed in the JPL standard method is an effective surface sterilant on both metals but not compatible with aluminum. It is recommended that titanium (Ti 6Al-4V) be considered superior to aluminum (Al 6061) for use in spacecraft sampling hardware, both for its potential to be cleaned to sterilization and for its ability to withstand the most effective cleaning protocols.

  6. Modelling the cost-effectiveness of impact-absorbing flooring in Swedish residential care facilities.

    PubMed

    Ryen, Linda; Svensson, Mikael

    2016-06-01

    Fall-related injuries among the elderly, specifically hip fractures, cause significant morbidity and mortality as well as imposing a substantial financial cost on the health care system. Impact-absorbing flooring has been advocated as an effective method for preventing hip fractures resulting from falls. This study identifies the cost-effectiveness of impact-absorbing flooring compared to standard flooring in residential care facilities for the elderly in a Swedish setting. An incremental cost-effectiveness analysis was performed comparing impact-absorbing flooring to standard flooring using a Markov decision model. A societal perspective was adopted and incremental costs were compared to incremental gains in quality-adjusted life years (QALYs). Data on costs, probability transitions and health-related quality of life measures were retrieved from the published literature and from Swedish register data. Probabilistic sensitivity analysis was performed through a Monte Carlo simulation. The base-case analysis indicates that the impact-absorbing flooring reduces costs and increases QALYs. When allowing for uncertainty we find that 60% of the simulations indicate that impact-absorbing flooring is cost-saving compared to standard flooring and an additional 20% that it has a cost per QALY below a commonly used threshold value : Using a modelling approach, we find that impact-absorbing flooring is a dominant strategy at the societal level considering that it can save resources and improve health in a vulnerable population. © The Author 2015. Published by Oxford University Press on behalf of the European Public Health Association. All rights reserved.

  7. An improved method for polarimetric image restoration in interferometry

    NASA Astrophysics Data System (ADS)

    Pratley, Luke; Johnston-Hollitt, Melanie

    2016-11-01

    Interferometric radio astronomy data require the effects of limited coverage in the Fourier plane to be accounted for via a deconvolution process. For the last 40 years this process, known as `cleaning', has been performed almost exclusively on all Stokes parameters individually as if they were independent scalar images. However, here we demonstrate for the case of the linear polarization P, this approach fails to properly account for the complex vector nature resulting in a process which is dependent on the axes under which the deconvolution is performed. We present here an improved method, `Generalized Complex CLEAN', which properly accounts for the complex vector nature of polarized emission and is invariant under rotations of the deconvolution axes. We use two Australia Telescope Compact Array data sets to test standard and complex CLEAN versions of the Högbom and SDI (Steer-Dwedney-Ito) CLEAN algorithms. We show that in general the complex CLEAN version of each algorithm produces more accurate clean components with fewer spurious detections and lower computation cost due to reduced iterations than the current methods. In particular, we find that the complex SDI CLEAN produces the best results for diffuse polarized sources as compared with standard CLEAN algorithms and other complex CLEAN algorithms. Given the move to wide-field, high-resolution polarimetric imaging with future telescopes such as the Square Kilometre Array, we suggest that Generalized Complex CLEAN should be adopted as the deconvolution method for all future polarimetric surveys and in particular that the complex version of an SDI CLEAN should be used.

  8. PubMed Central

    Baeßler, Kaven; Junginger, Bärbel

    2017-01-01

    Background The aims of physiotherapy in stress incontinent women are to improve pelvic floor function and the continence mechanism including bladder neck support and urethral closure pressure. In Germany, traditional conservative treatment often includes gymnastic exercises with unclear effects on the bladder neck. The aim of this study was to sonographically assess bladder neck movements during selected exercises. Methods Fifteen healthy, continent women without previous vaginal births, who were able to voluntarily contract their pelvic floor muscels performed the shoulder bridge, the abdominal press, tiptoe and the Pilates clam exercises. The first set was performed without any additional instructions. During the second set directions were given to activate the pelvic floor before beginning each exercise and to maintain the contraction throughout the exercise. Bladder neck movement was measured on perineal ultrasound using a validated method with the pubic symphysis as a reference point. Results The median age of participants was 32 years, median BMI was 23. Eight women were nulliparous and seven had given birth to 1 – 2 children via caesarean section. When exercises were performed without voluntary pelvic floor contraction the bladder neck descended on average between 2.3 and 4.4 mm, and with pelvic floor contraction prior to the exercise only between 0.5 and 2.1 mm (p > 0.05 except for abdominal press p = 0.007). The Pilates clam exercise and toe stand stabilised the bladder neck most effectively. Discussion Bladder neck descent often occurs during pelvic floor gymnastic exercises as traditionally performed in Germany, and a voluntary pelvic floor contraction during the exercises does not necessarily prevent this. PMID:28757655

  9. Impacts of building geometry modeling methods on the simulation results of urban building energy models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Yixing; Hong, Tianzhen

    We present that urban-scale building energy modeling (UBEM)—using building modeling to understand how a group of buildings will perform together—is attracting increasing attention in the energy modeling field. Unlike modeling a single building, which will use detailed information, UBEM generally uses existing building stock data consisting of high-level building information. This study evaluated the impacts of three zoning methods and the use of floor multipliers on the simulated energy use of 940 office and retail buildings in three climate zones using City Building Energy Saver. The first zoning method, OneZone, creates one thermal zone per floor using the target building'smore » footprint. The second zoning method, AutoZone, splits the building's footprint into perimeter and core zones. A novel, pixel-based automatic zoning algorithm is developed for the AutoZone method. The third zoning method, Prototype, uses the U.S. Department of Energy's reference building prototype shapes. Results show that simulated source energy use of buildings with the floor multiplier are marginally higher by up to 2.6% than those modeling each floor explicitly, which take two to three times longer to run. Compared with the AutoZone method, the OneZone method results in decreased thermal loads and less equipment capacities: 15.2% smaller fan capacity, 11.1% smaller cooling capacity, 11.0% smaller heating capacity, 16.9% less heating loads, and 7.5% less cooling loads. Source energy use differences range from -7.6% to 5.1%. When comparing the Prototype method with the AutoZone method, source energy use differences range from -12.1% to 19.0%, and larger ranges of differences are found for the thermal loads and equipment capacities. This study demonstrated that zoning methods have a significant impact on the simulated energy use of UBEM. Finally, one recommendation resulting from this study is to use the AutoZone method with floor multiplier to obtain accurate results while balancing the simulation run time for UBEM.« less

  10. Impacts of building geometry modeling methods on the simulation results of urban building energy models

    DOE PAGES

    Chen, Yixing; Hong, Tianzhen

    2018-02-20

    We present that urban-scale building energy modeling (UBEM)—using building modeling to understand how a group of buildings will perform together—is attracting increasing attention in the energy modeling field. Unlike modeling a single building, which will use detailed information, UBEM generally uses existing building stock data consisting of high-level building information. This study evaluated the impacts of three zoning methods and the use of floor multipliers on the simulated energy use of 940 office and retail buildings in three climate zones using City Building Energy Saver. The first zoning method, OneZone, creates one thermal zone per floor using the target building'smore » footprint. The second zoning method, AutoZone, splits the building's footprint into perimeter and core zones. A novel, pixel-based automatic zoning algorithm is developed for the AutoZone method. The third zoning method, Prototype, uses the U.S. Department of Energy's reference building prototype shapes. Results show that simulated source energy use of buildings with the floor multiplier are marginally higher by up to 2.6% than those modeling each floor explicitly, which take two to three times longer to run. Compared with the AutoZone method, the OneZone method results in decreased thermal loads and less equipment capacities: 15.2% smaller fan capacity, 11.1% smaller cooling capacity, 11.0% smaller heating capacity, 16.9% less heating loads, and 7.5% less cooling loads. Source energy use differences range from -7.6% to 5.1%. When comparing the Prototype method with the AutoZone method, source energy use differences range from -12.1% to 19.0%, and larger ranges of differences are found for the thermal loads and equipment capacities. This study demonstrated that zoning methods have a significant impact on the simulated energy use of UBEM. Finally, one recommendation resulting from this study is to use the AutoZone method with floor multiplier to obtain accurate results while balancing the simulation run time for UBEM.« less

  11. Force-length relationship in the pelvic floor muscles under transverse vaginal distension: a method study in healthy women.

    PubMed

    Verelst, M; Leivseth, G

    2004-01-01

    The purpose of this study was to investigate whether there is a relationship between changes in the diameter of the urogenital hiatus and force developed in pelvic floor musculature. In addition, we wanted to examine the reliability of the method that measures force development in the pelvic floor in the transverse direction of the urogenital hiatus. Passive and total force in the pelvic floor was measured with an intra-vaginal device in 20 healthy parous volunteers. The measurements were done with a consecutively increasing diameter in the transverse plane of the urogenital hiatus. The procedure was repeated with a few days interval. The measurements show an increase in force with an increasing device-diameter. The results are reliable at all the diameters tested, estimated by the within-subject day-to-day variability which was non-significant. The 40 mm diameter device is most favourable, estimated by Bland Altman plots of the test-retest measurements. Force development in pelvic floor muscles increased as a function of vaginal diameter when measured in the frontal plane. The measurements were reliable at all the different diameters chosen. 2004 Wiley-Liss, Inc.

  12. Role of conventional radiology and MRi defecography of pelvic floor hernias

    PubMed Central

    2013-01-01

    Background Purpose of the study is to define the role of conventional radiology and MRI in the evaluation of pelvic floor hernias in female pelvic floor disorders. Methods A MEDLINE and PubMed search was performed for journals before March 2013 with MeSH major terms 'MR Defecography' and 'pelvic floor hernias'. Results The prevalence of pelvic floor hernias at conventional radiology was higher if compared with that at MRI. Concerning the hernia content, there were significantly more enteroceles and sigmoidoceles on conventional radiology than on MRI, whereas, in relation to the hernia development modalities, the prevalence of elytroceles, edroceles, and Douglas' hernias at conventional radiology was significantly higher than that at MRI. Conclusions MRI shows lower sensitivity than conventional radiology in the detection of pelvic floor hernias development. The less-invasive MRI may have a role in a better evaluation of the entire pelvic anatomy and pelvic organ interaction especially in patients with multicompartmental defects, planned for surgery. PMID:24267789

  13. Plasma Cleaning

    NASA Technical Reports Server (NTRS)

    Hintze, Paul E.

    2016-01-01

    NASA's Kennedy Space Center has developed two solvent-free precision cleaning techniques: plasma cleaning and supercritical carbon dioxide (SCCO2), that has equal performance, cost parity, and no environmental liability, as compared to existing solvent cleaning methods.

  14. Evaluation of surface roughness of enamel after various bonding and clean-up procedures on enamel bonded with three different bonding agents: An in-vitro study

    PubMed Central

    Goel, Amit; Singh, Atul; Gupta, Tarun

    2017-01-01

    Background The purpose of this study was to analyze and compare the enamel surface roughness before bonding and after debonding, to find correlation between the adhesive remnant index and its effect on enamel surface roughness and to evaluate which clean-up method is most efficient to provide a smoother enamel surface. Material and Methods 135 premolars were divided into 3 groups containing 45 premolars in each group. Group I was bonded by using moisture insensitive primer, Group II by using conventional orthodontic adhesive and Group III by using self-etching primer. Each group was divided into 3 sub-groups on the basis of type of clean-up method applied i,e scaling followed by polishing, tungsten carbide bur and Sof-Lex disc. Enamel surface roughness was measured and compared before bonding and after clean-up. Results Evaluation of pre bonding and post clean-up enamel surface roughness (Ra value) with the t test showed that Post clean-up Ra values were greater than Pre bonding Ra values in all the groups except in teeth bonded with self-etching primer cleaned with Sof-Lex disc. Reliability of ARI score taken at different time interval tested with Kruskal Wallis test suggested that all the readings were reliable. Conclusions No clean-up procedure was able to restore the enamel to its original smoothness. Self-etching primer and Sof-Lex disc clean-up method combination restored the enamel surface roughness (Ra value) closest to its pre-treatment value. Key words:Enamel surface roughness, clean-up method, adhesive remnant index. PMID:28512535

  15. Optimization of the cleaning process on a pilot filtration setup for waste water treatment accompanied by flow visualization

    NASA Astrophysics Data System (ADS)

    Bílek, Petr; Hrůza, Jakub

    2018-06-01

    This paper deals with an optimization of the cleaning process on a liquid flat-sheet filter accompanied by visualization of the inlet side of a filter. The cleaning process has a crucial impact on the hydrodynamic properties of flat-sheet filters. Cleaning methods avoid depositing of particles on the filter surface and forming a filtration cake. Visualization significantly helps to optimize the cleaning methods, because it brings new overall view on the filtration process in time. The optical method, described in the article, enables to see flow behaviour in a thin laser sheet on the inlet side of a tested filter during the cleaning process. Visualization is a strong tool for investigation of the processes on filters in details and it is also possible to determine concentration of particles after an image analysis. The impact of air flow rate, inverse pressure drop and duration on the cleaning mechanism is investigated in the article. Images of the cleaning process are compared to the hydrodynamic data. The tests are carried out on a pilot filtration setup for waste water treatment.

  16. Contamination removal using various solvents and methodologies

    NASA Technical Reports Server (NTRS)

    Jeppsen, J. C.

    1989-01-01

    Critical and non-critical bonding surfaces must be kept free of contamination that may cause potential unbonds. For example, an aft-dome section of a redesigned solid rocket motor that had been contaminated with hydraulic oil did not appear to be sufficiently cleaned when inspected by the optically stimulated electron emission process (Con Scan) after it had been cleaned using a hand double wipe cleaning method. As a result, current and new cleaning methodologies as well as solvent capability in removing various contaminant materials were reviewed and testing was performed. Bonding studies were also done to verify that the cleaning methods used in removing contaminants provide an acceptable bonding surface. The removal of contaminants from a metal surface and the strength of subsequent bonds were tested using the Martin Marietta and double-wipe cleaning methods. Results are reported.

  17. Limonene and tetrahydrofurfurly alcohol cleaning agent

    DOEpatents

    Bohnert, George W.; Carter, Richard D.; Hand, Thomas E.; Powers, Michael T.

    1997-10-21

    The present invention is a tetrahydrofurfuryl alcohol and limonene cleaning agent and method for formulating and/or using the cleaning agent. This cleaning agent effectively removes both polar and nonpolar contaminants from various electrical and mechanical parts and is readily used without surfactants, thereby reducing the need for additional cleaning operations. The cleaning agent is warm water rinsable without the use of surfactants. The cleaning agent can be azeotropic, enhancing ease of use in cleaning operations and ease of recycling.

  18. Limonene and tetrahydrofurfuryl alcohol cleaning agent

    DOEpatents

    Bohnert, G.W.; Carter, R.D.; Hand, T.E.; Powers, M.T.

    1997-10-21

    The present invention is a tetrahydrofurfuryl alcohol and limonene cleaning agent and method for formulating and/or using the cleaning agent. This cleaning agent effectively removes both polar and nonpolar contaminants from various electrical and mechanical parts and is readily used without surfactants, thereby reducing the need for additional cleaning operations. The cleaning agent is warm water rinsable without the use of surfactants. The cleaning agent can be azeotropic, enhancing ease of use in cleaning operations and ease of recycling.

  19. Assessment of hospital daily cleaning practices using ATP bioluminescence in a developing country.

    PubMed

    Zambrano, Alejandra A; Jones, Alex; Otero, Paula; Ajenjo, Maria Cristina; Labarca, Jaime A

    2014-01-01

    Visual assessment of surfaces may not be enough to document the level of cleanliness in the hospital setting. It is necessary to introduce quantitative methods to document the results of this practice. To evaluate the efficacy of hospital terminal cleaning procedures, using an adenosine triphosphate (ATP) bioluminescence method in a teaching hospital. During 2008 we conducted an evaluation using ATP bioluminescence LIGHTNING MVP™ (Arquimed) of external and internal housekeeping service. After conducting an initial evaluation we implemented education of cleaning practices and finally we did a post intervention evaluation. Using chi-square method we compared prior versus after cleaning, quality of cleaning performed by external versus internal personnel, single versus double terminal cleaning procedures and prior versus after intervention. A finding of three RLU or less was considered a clean surface. We performed 198 evaluations in 33 patient units and nine OR. Internal personnel accomplished 25.37% of clean surfaces before and 80% after the education intervention (p=0.01). In contrast, external personnel obtained 68.8% before and 73.33% after intervention (p=0.3). This study suggests that visual assessment is not enough to ensure quality of the process and it is necessary to document the level of cleanliness by quantitative methods. Copyright © 2014 Elsevier Editora Ltda. All rights reserved.

  20. Accuracy of a new clean-catch technique for diagnosis of urinary tract infection in infants younger than 90 days of age

    PubMed Central

    Herreros, María Luisa; Tagarro, Alfredo; García-Pose, Araceli; Sánchez, Aida; Cañete, Alfonso; Gili, Pablo

    2015-01-01

    OBJECTIVE: To evaluate the accuracy of diagnosing urinary tract infections using a new, recently described, standardized clean-catch collection technique. METHODS: Cross-sectional study of infants <90 days old admitted due to fever without a source, with two matched samples of urine obtained using two different methods: clean-catch standardized stimulation technique and bladder catheterization. RESULTS: Sixty paired urine cultures were obtained. The median age was 44-days-old. Seventeen percent were male infants. Clean-catch technique sensitivity was 97% (95% CI 82% to 100%) and specificity was 89% (95% CI 65% to 98%). The contamination rate of clean-catch samples was lower (5%) than the contamination rate of catheter specimens (8%). CONCLUSIONS: The sensitivity and specificity of urine cultures obtained using the clean-catch method through the new technique were accurate and the contamination rate was low. These results suggest that this technique is a valuable, alternative method for urinary tract infection diagnosis. PMID:26435675

  1. Performance and quality-control standards for composite floor, wall, and truss framing

    Treesearch

    Gerald A. Koenigshof

    1985-01-01

    Users must be assured that composite structural members are satisfactory for their intended purposes. Standards are provided for strength, stiffness, durability, and dimensional stability of composite floor, wall, and truss-framing members. Methods for enforcing compliance with the standards are suggested.

  2. Carbon dioxide and methane emissions from the scale model of open dairy lots.

    PubMed

    Ding, Luyu; Cao, Wei; Shi, Zhengxiang; Li, Baoming; Wang, Chaoyuan; Zhang, Guoqiang; Kristensen, Simon

    2016-07-01

    To investigate the impacts of major factors on carbon loss via gaseous emissions, carbon dioxide (CO2) and methane (CH4) emissions from the ground of open dairy lots were tested by a scale model experiment at various air temperatures (15, 25, and 35 °C), surface velocities (0.4, 0.7, 1.0, and 1.2 m sec(-1)), and floor types (unpaved soil floor and brick-paved floor) in controlled laboratory conditions using the wind tunnel method. Generally, CO2 and CH4 emissions were significantly enhanced with the increase of air temperature and velocity (P < 0.05). Floor type had different effects on the CO2 and CH4 emissions, which were also affected by air temperature and soil characteristics of the floor. Although different patterns were observed on CH4 emission from the soil and brick floors at different air temperature-velocity combinations, statistical analysis showed no significant difference in CH4 emissions from different floors (P > 0.05). For CO2, similar emissions were found from the soil and brick floors at 15 and 25 °C, whereas higher rates were detected from the brick floor at 35 °C (P < 0.05). Results showed that CH4 emission from the scale model was exponentially related to CO2 flux, which might be helpful in CH4 emission estimation from manure management. Gaseous emissions from the open lots are largely dependent on outdoor climate, floor systems, and management practices, which are quite different from those indoors. This study assessed the effects of floor types and air velocities on CO2 and CH4 emissions from the open dairy lots at various temperatures by a wind tunnel. It provided some valuable information for decision-making and further studies on gaseous emissions from open lots.

  3. Limonene and tetrahydrofurfuryl alcohol cleaning agent

    DOEpatents

    Bohnert, George W.; Carter, Richard D.; Hand, Thomas E.; Powers, Michael T.

    1996-05-07

    The present invention is a tetrahydrofurfuryl alcohol and limonene or terpineol cleaning agent and method for formulating and/or using the cleaning agent. This cleaning agent effectively removes both polar and nonpolar contaminants from various electrical and mechanical parts and is readily used without surfactants, thereby reducing the need for additional cleaning operations. The cleaning agent is warm water rinsable without the use of surfactants. The cleaning agent can be azeotropic, enhancing ease of use in cleaning operations and ease of recycling.

  4. Accuracy of integrated total pelvic floor ultrasound compared to defaecatory MRI in females with pelvic floor defaecatory dysfunction

    PubMed Central

    Pilkington, Sophie A; Grierson, Catherine; Rutherford, Elizabeth; Schizas, Alexis M P; Nugent, Karen P; Williams, Andrew B

    2016-01-01

    Objective: Defaecatory MRI allows multicompartmental assessment of defaecatory dysfunction but is often inaccessible. Integrated total pelvic floor ultrasound (transperineal, transvaginal, endoanal) may provide a cheap, portable alternative. The accuracy of total pelvic floor ultrasound for anatomical abnormalities when compared with defaecatory MRI was assessed. Methods: The dynamic images from 68 females who had undergone integrated total pelvic floor ultrasound and defaecatory MRI between 2009 and 2015 were blindly reviewed. The following were recorded: rectocoele, enterocoele, intussusception and cystocoele. Results: There were 26 rectocoeles on MRI (49 rectocoeles on ultrasound), 24 rectocoeles with intussusception on MRI (19 rectocoeles on ultrasound), 23 enterocoeles on MRI (24 enterocoeles on ultrasound) and 49 cystocoeles on MRI (35 cystocoeles on ultrasound). Sensitivity and specificity of total pelvic floor ultrasound were 81% and 33% for rectocoele, 60% and 91% for intussusception, 65% and 80% for enterocoele and 65% and 84% for cystocoele when compared with defaecatory MRI. This gave a negative-predictive value and positive-predictive value of 74% and 43% for rectocoele, 80% and 79% for intussusception, 82% and 63% for enterocoele and 48% and 91% for cystocoele. Conclusion: Integrated total pelvic floor ultrasound may serve as a screening tool for pelvic floor defaecatory dysfunction; when normal, defaecatory MRI can be avoided, as rectocoele, intussusception and enterocoele are unlikely to be present. Advances in knowledge: This is the first study to compare integrated total pelvic floor ultrasound with defaecatory MRI. The results support the use of integrated total pelvic floor ultrasound as a screening tool for defaecatory dysfunction. PMID:27730818

  5. Cross-sectional study of frequency and factors associated with stethoscope cleaning among medical practitioners in Pakistan.

    PubMed

    Hyder, O

    2012-07-01

    Stethoscope diaphragms are frequently colonized by bacteria. This cross-sectional study described the frequency and factors associated with reporting ever cleaning stethoscopes among 408 medical students and doctors at a medical college and 2 teaching hospitals in Rawalpindi, Pakistan. A minority of the respondents (37.7%) reported having ever cleaned their stethoscope. Following normal clinical use, wiping with a dry cloth was the most frequently reported method of cleaning (53.2%). After contamination of the diaphragm with blood or secretions, cleaning with an alcoholic swab was the most common method (64.3%). In univariate and multivariate analyses, history of receiving information on stethoscope cleaning, utilization of personal stethoscope at last use and affiliation with internal medicine department were factors strongly associated with ever cleaning of stethoscope. Future research for improving stethoscope cleaning practices should explore educational interventions aimed at health care professionals.

  6. Cheap non-toxic non-corrosive method of glass cleaning evaluated by contact angle, AFM, and SEM-EDX measurements.

    PubMed

    Dey, Tania; Naughton, Daragh

    2017-05-01

    Glass surface cleaning is the very first step in advanced coating deposition and it also finds use in conserving museum objects. However, most of the wet chemical methods of glass cleaning use toxic and corrosive chemicals like concentrated sulfuric acid (H 2 SO 4 ), piranha (a mixture of concentrated sulfuric acid and 30% hydrogen peroxide), and hydrogen fluoride (HF). On the other hand, most of the dry cleaning techniques like UV-ozone, plasma, and laser treatment require costly instruments. In this report, five eco-friendly wet chemical methods of glass cleaning were evaluated in terms of contact angle (measured by optical tensiometer), nano-scale surface roughness (measured by atomic force microscopy or AFM), and elemental composition (measured by energy dispersive x-ray spectroscopy or SEM-EDX). These glass cleaning methods are devoid of harsh chemicals and costly equipment, hence can be applied in situ in close proximity with plantation such as greenhouse or upon subtle objects such as museum artifacts. Out of these five methods, three methods are based on the chemical principle of chelation. It was found that the citric acid cleaning method gave the greatest change in contact angle within the hydrophilic regime (14.25° for new glass) indicating effective cleansing and the least surface roughness (0.178 nm for new glass) indicating no corrosive effect. One of the glass sample showed unique features which were traced backed to the history of the glass usage.

  7. Transport characteristics of expiratory droplets and droplet nuclei in indoor environments with different ventilation airflow patterns.

    PubMed

    Wan, M P; Chao, C Y H

    2007-06-01

    Expiratory droplets and droplet nuclei can be pathogen carriers for airborne diseases. Their transport characteristics were studied in detail in two idealized floor-supply-type ventilation flow patterns: Unidirectional-upward and single-side-floor, using a multiphase numerical model. The model was validated by running interferometric Mie imaging experiments using test droplets with nonvolatile content, which formed droplet nuclei, ultimately, in a class-100 clean-room chamber. By comparing the droplet dispersion and removal characteristics with data of two other ceiling-supply ventilation systems collected from a previous work, deviations from the perfectly mixed ventilation condition were found to exist in various cases to different extent. The unidirectional-upward system was found to be more efficient in removing the smallest droplet nuclei (formed from 1.5 mum droplets) by air extraction, but it became less effective for larger droplets and droplet nuclei. Instead, the single-side-floor system was shown to be more favorable in removing these large droplets and droplet nuclei. In the single-side-floor system, the lateral overall dispersion coefficients for the small droplets and nuclei (initial size

  8. [Primary functional reconstruction of the floor of the mouth following surgery for cancer (author's transl)].

    PubMed

    Arnold, W; Vosteen, K H

    1979-08-01

    The authors tell of their experience with the reconstruction of the floor of the mouth following surgery for cancer. They feel that especially in older patients with bad general condition the simplest surgical methods of reconstruction are the best.

  9. Dual-stiffness flooring: can it reduce fracture rates associated with falls?

    PubMed

    Knoefel, Frank; Patrick, Louise; Taylor, Jodie; Goubran, Rafik

    2013-04-01

    Falls cause significant morbidity and mortality in long term care facilities. Dual-stiffness flooring (DSF) has previously shown promise in reducing such morbidity in experimental models. This study set out to measure the impact of SmartCell flooring on falls-related morbidity in a nursing home. All falls occurring at an Arizona nursing home between July 1, 2008, and December 31, 2010, were reviewed for age, sex, diagnosis of osteoporosis, number of medications, history of previous falls, type of flooring (normal vs DSF), time of day, type of injury, and resulting actions. Fall-related outcomes were compared across room types using chi-square and logistic regression methods. Eighty-two falls on the DSF were compared with 85 falls on the regular floor. There was a tendency for residents falling on DSF to have less bruising and abrasions, while having more redness and cuts. There were 2 fractures on regular flooring (2.4% fracture rate) and none on the DSF flooring (0% fracture rate). The fracture rate of 2.4% of falls on the regular floor is consistent with previous reports in the literature, whereas a 0% rate found on the DSF floor is a clinically significant improvement. This suggests that DSF may be a practical approach for institutions and consumers to reduce fall-related injuries. A larger scale controlled study to confirm these encouraging preliminary findings is warranted. Copyright © 2013 American Medical Directors Association, Inc. Published by Elsevier Inc. All rights reserved.

  10. Manual versus automated methods for cleaning reusable accessory devices used for minimally invasive surgical procedures.

    PubMed

    Alfa, M J; Nemes, R

    2004-09-01

    We undertook a simulated-use study using quantitative methods to evaluate the cleaning efficacy of ported and non-ported accessory devices used in minimally invasive surgery. We chose laparoscopic scissors and forceps to represent worst-case devices which were inoculated with artificial test soil containing 10(6) cfu/mL Enterococcus faecalis and Geobacillus stearothermophilus and allowed to dry for 1 h. Cleaning was performed manually, as well as by the automated SI-Auto Narrow lumen cleaner. Manual cleaning left two- to 50-fold more soil residuals (protein, haemoglobin and carbohydrate) inside the lumen of non-ported versus ported laparoscopic accessory devices. The SI-Auto Narrow lumen cleaner was more efficient than manual cleaning and achieved >99% reduction in soil parameters in both non-ported (using retro-flushing) and ported laparoscopic devices. Only the automated cleaning of ported devices achieved 10(3)-10(4)-fold reduction in bacterial numbers. Sonication alone (no flushing of inner channel) did not effectively remove soil or organisms from the inner channel. Our findings indicate that non-ported accessory devices cannot be as reliably cleaned as ported devices regardless of the cleaning method used. If non-ported accessory devices are reprocessed, they should be cleaned using retro-flushing in an automated narrow lumen cleaner.

  11. Comparison of survivability of Staphylococcus aureus and spores of Aspergillus niger on commonly used floor materials.

    PubMed

    Gupta, Mridula; Bisesi, Michael; Lee, Jiyoung

    2017-07-01

    The survivability of Staphylococcus aureus and spores of Aspergillus niger was compared on 5 common floor materials. Floor materials were inoculated with a known concentration of S aureus and spores of A niger on day 0. Their survivability was measured on days, 2, 7, 14, and 28 by bulk rinsate method and enumerated using culture-based method. The difference in change of S aureus levels was statistically significant for all tested days (P < .001) for all floor materials. Vinyl composition tile (VCT) and porcelain tile (PT) had statistically similar survivability and differed statistically from carpets. On both VCT and PT, positive growth for S aureus occurred by day 2 (1-1.7 log 10 ), declined slightly (0.1 to -0.2 log 10 ) by day 7, and remained positive until day 28. However, S aureus was undetected by day 7 on both carpets. A niger spores were undetected on residential broadloom carpet and rubber-backed commercial carpet after day 2 but survived on VCT, PT, and wood until day 28. Floor materials with hard and smooth surfaces, such as VCT and PT, can allow survival of S aureus and A niger for up to 4 weeks. It may imply that floor materials can play a major role in preserving microbial contaminants in the built environment. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  12. Polypropylene Darning: A New Alternative for Reconstruction of Orbital Floor after Total Maxillectomy.

    PubMed

    Sharma, Prashant

    2015-06-01

    Removal of orbital floor is an integral part of total (radical) maxillectomy (type IIIa), which if not managed properly, may lead to some eye related distressing complications like diplopia, eyelid malposition, epiphora, dacryocystitis, enopthalmos and ectoprion. Among all, diplopia is the most distressing complication which hampers daily activity. Various options for orbital floor reconstruction are available like titanium sheet, polypropylene mesh, non-vascularized or vascularized bone graft, pedicled flaps, micro-vascular free flaps, prosthesis placement, and split skin graft followed by obturator placement. Till date no-body has tried stabilization of eye ball by 'darning' the orbital floor using non-absorbable suture. 'Polypropylene suture darning' is an easy to learn, novel method with equally good results. Five patients with potentially resectable tumors underwent total maxillectomy. I used polypropylene 3-0 round body suture and 'darning' was done at orbital floor, incorporating periosteum (if remaining) and peri-orbital fat into the sutures. Muscle flaps were done to provide bulk and palatal reconstruction. Assessment of patients was done post-operatively at day-5 i.e., before discharge and at 1 month after surgery, and also in further follow up visits. The results were very good in terms of clear vision & eye movements (directly related to 'darning'), and the aesthetic look of patients and bilateral symmetry were satisfactory (not related to darning). Darning of orbital floor by polypropylene after total maxillectomy is an easy to learn and cost-effective method of reconstruction with good results.

  13. [Analysis and research on cleaning points of HVAC systems in public places].

    PubMed

    Yang, Jiaolan; Han, Xu; Chen, Dongqing; Jin, Xin; Dai, Zizhu

    2010-03-01

    To analyze cleaning points of HVAC systems, and to provides scientific base for regulating the cleaning of HVAC systems. Based on the survey results on the cleaning situation of HVAC systems around China for the past three years, we analyzes the cleaning points of HVAC systems from various aspects, such as the major health risk factors of HVAC systems, the formulation strategy of the cleaning of HVAC systems, cleaning methods and acceptance points of the air ducts and the parts of HVAC systems, the onsite protection and individual protection, the waste treatment and the cleaning of the removed equipment, inspection of the cleaning results, video record, and the final acceptance of the cleaning. The analysis of the major health risk factors of HVAC systems and the formulation strategy of the cleaning of HVAC systems is given. The specific methods for cleaning the air ducts, machine units, air ports, coil pipes and the water cooling towers of HVAC systems, the acceptance points of HVAC systems and the requirements of the report on the final acceptance of the cleaning of HVAC systems are proposed. By the analysis of the points of the cleaning of HVAC systems and proposal of corresponding measures, this study provides the base for the scientific and regular launch of the cleaning of HVAC systems, a novel technology service, and lays a foundation for the revision of the existing cleaning regulations, which may generate technical and social benefits to some extent.

  14. Evaluation of two cleaning methods for the removal of asbestos fibers from carpet

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kominsky, J.R.; Freyberg, R.W.; Chesson, J.

    The research study examined the effectiveness of dry vacuuming and wet cleaning for the removal of asbestos fibers from carpet, and evaluated the potential for fiber reentrainment during carpet cleaning activities. Routine carpet cleaning operations using high-efficiency particulate air (HEPA) filtered dry vacuum cleaners and HEPA-filtered hot-water extraction cleaners were simulated on carpet artificially contaminated with asbestos fibers. Overall, wet cleaning the carpet with a hot-water extraction cleaner reduced the level of asbestos contamination by approximately 70 percent. There was no significant evidence of either an increase or a decrease in the asbestos concentration after dry vacuuming. The level ofmore » asbestos contamination had no significant effect on the difference between the carpet asbestos concentrations before and after cleaning. Airborne asbestos concentrations were between two and four times greater during the carpet cleaning activities. The level of asbestos contamination in the carpet cleaning activities. The level of asbestos contamination in the carpet and the type of cleaning method used had no statistically significant effect on the difference between the airborne asbestos concentrations before and during cleaning.« less

  15. Using Ozone To Clean and Passivate Oxygen-Handling Hardware

    NASA Technical Reports Server (NTRS)

    Torrance, Paul; Biesinger, Paul

    2009-01-01

    A proposed method of cleaning, passivating, and verifying the cleanliness of oxygen-handling hardware would extend the established art of cleaning by use of ozone. As used here, "cleaning" signifies ridding all exposed surfaces of combustible (in particular, carbon-based) contaminants. The method calls for exposing the surfaces of the hardware to ozone while monitoring the ozone effluent for carbon dioxide. The ozone would passivate the hardware while oxidizing carbon-based residues, converting the carbon in them to carbon dioxide. The exposure to ozone would be continued until no more carbon dioxide was detected, signifying that cleaning and passivation were complete.

  16. Development and assessment of floor and ceiling items for the PROMIS physical function item bank

    PubMed Central

    2013-01-01

    Introduction Disability and Physical Function (PF) outcome assessment has had limited ability to measure functional status at the floor (very poor functional abilities) or the ceiling (very high functional abilities). We sought to identify, develop and evaluate new floor and ceiling items to enable broader and more precise assessment of PF outcomes for the NIH Patient-Reported-Outcomes Measurement Information System (PROMIS). Methods We conducted two cross-sectional studies using NIH PROMIS item improvement protocols with expert review, participant survey and focus group methods. In Study 1, respondents with low PF abilities evaluated new floor items, and those with high PF abilities evaluated new ceiling items for clarity, importance and relevance. In Study 2, we compared difficulty ratings of new floor items by low functioning respondents and ceiling items by high functioning respondents to reference PROMIS PF-10 items. We used frequencies, percentages, means and standard deviations to analyze the data. Results In Study 1, low (n = 84) and high (n = 90) functioning respondents were mostly White, women, 70 years old, with some college, and disability scores of 0.62 and 0.30. More than 90% of the 31 new floor and 31 new ceiling items were rated as clear, important and relevant, leaving 26 ceiling and 30 floor items for Study 2. Low (n = 246) and high (n = 637) functioning Study 2 respondents were mostly White, women, 70 years old, with some college, and Health Assessment Questionnaire (HAQ) scores of 1.62 and 0.003. Compared to difficulty ratings of reference items, ceiling items were rated to be 10% more to greater than 40% more difficult to do, and floor items were rated to be about 12% to nearly 90% less difficult to do. Conclusions These new floor and ceiling items considerably extend the measurable range of physical function at either extreme. They will help improve instrument performance in populations with broad functional ranges and those concentrated at one or the other extreme ends of functioning. Optimal use of these new items will be assisted by computerized adaptive testing (CAT), reducing questionnaire burden and insuring item administration to appropriate individuals. PMID:24286166

  17. Quantitative assessment of airborne exposures generated during common cleaning tasks: a pilot study

    PubMed Central

    2010-01-01

    Background A growing body of epidemiologic evidence suggests an association between exposure to cleaning products with asthma and other respiratory disorders. Thus far, these studies have conducted only limited quantitative exposure assessments. Exposures from cleaning products are difficult to measure because they are complex mixtures of chemicals with a range of physicochemical properties, thus requiring multiple measurement techniques. We conducted a pilot exposure assessment study to identify methods for assessing short term, task-based airborne exposures and to quantitatively evaluate airborne exposures associated with cleaning tasks simulated under controlled work environment conditions. Methods Sink, mirror, and toilet bowl cleaning tasks were simulated in a large ventilated bathroom and a small unventilated bathroom using a general purpose, a glass, and a bathroom cleaner. All tasks were performed for 10 minutes. Airborne total volatile organic compounds (TVOC) generated during the tasks were measured using a direct reading instrument (DRI) with a photo ionization detector. Volatile organic ingredients of the cleaning mixtures were assessed utilizing an integrated sampling and analytic method, EPA TO-17. Ammonia air concentrations were also measured with an electrochemical sensor embedded in the DRI. Results Average TVOC concentrations calculated for 10 minute tasks ranged 0.02 - 6.49 ppm and the highest peak concentrations observed ranged 0.14-11 ppm. TVOC time concentration profiles indicated that exposures above background level remained present for about 20 minutes after cessation of the tasks. Among several targeted VOC compounds from cleaning mixtures, only 2-BE was detectable with the EPA method. The ten minute average 2- BE concentrations ranged 0.30 -21 ppm between tasks. The DRI underestimated 2-BE exposures compared to the results from the integrated method. The highest concentration of ammonia of 2.8 ppm occurred during mirror cleaning. Conclusions Our results indicate that airborne exposures from short-term cleaning tasks can remain in the air even after tasks' cessation, suggesting potential exposures to anyone entering the room shortly after cleaning. Additionally, 2-BE concentrations from cleaning could approach occupational exposure limits and warrant further investigation. Measurement methods applied in this study can be useful for workplace assessment of airborne exposures during cleaning, if the limitations identified here are addressed. PMID:21118559

  18. Simultaneous imaging/reflectivity measurements to assess diagnostic mirror cleaning.

    PubMed

    Skinner, C H; Gentile, C A; Doerner, R

    2012-10-01

    Practical methods to clean ITER's diagnostic mirrors and restore reflectivity will be critical to ITER's plasma operations. We describe a technique to assess the efficacy of mirror cleaning techniques and detect any damage to the mirror surface. The method combines microscopic imaging and reflectivity measurements in the red, green, and blue spectral regions and at selected wavelengths. The method has been applied to laser cleaning of single crystal molybdenum mirrors coated with either carbon or beryllium films 150-420 nm thick. It is suitable for hazardous materials such as beryllium as the mirrors remain sealed in a vacuum chamber.

  19. Compliant flooring to prevent fall-related injuries in older adults: A scoping review of biomechanical efficacy, clinical effectiveness, cost-effectiveness, and workplace safety

    PubMed Central

    Jurkowski, Michal P.; Dymarz, Ania C.; Robinovitch, Stephen N.; Feldman, Fabio; Laing, Andrew C.; Mackey, Dawn C.

    2017-01-01

    Background Compliant flooring, broadly defined as flooring systems or floor coverings with some level of shock absorbency, may reduce the incidence and severity of fall-related injuries in older adults; however, a lack of synthesized evidence may be limiting widespread uptake. Methods Informed by the Arksey and O’Malley framework and guided by a Research Advisory Panel of knowledge users, we conducted a scoping review to answer: what is presented about the biomechanical efficacy, clinical effectiveness, cost-effectiveness, and workplace safety associated with compliant flooring systems that aim to prevent fall-related injuries in healthcare settings? We searched academic and grey literature databases. Any record that discussed a compliant flooring system and at least one of biomechanical efficacy, clinical effectiveness, cost-effectiveness, or workplace safety was eligible for inclusion. Two independent reviewers screened and abstracted records, charted data, and summarized results. Results After screening 3611 titles and abstracts and 166 full-text articles, we included 84 records plus 56 companion (supplementary) reports. Biomechanical efficacy records (n = 50) demonstrate compliant flooring can reduce fall-related impact forces with minimal effects on standing and walking balance. Clinical effectiveness records (n = 20) suggest that compliant flooring may reduce injuries, but may increase risk for falls. Preliminary evidence suggests that compliant flooring may be a cost-effective strategy (n = 12), but may also result in increased physical demands for healthcare workers (n = 17). Conclusions In summary, compliant flooring is a promising strategy for preventing fall-related injuries from a biomechanical perspective. Additional research is warranted to confirm whether compliant flooring (i) prevents fall-related injuries in real-world settings, (ii) is a cost-effective intervention strategy, and (iii) can be installed without negatively impacting workplace safety. Avenues for future research are provided, which will help to determine whether compliant flooring is recommended in healthcare environments. PMID:28166265

  20. Designing and Testing of Self-Cleaning Recirculating Zebrafish Tanks.

    PubMed

    Nema, Shubham; Bhargava, Yogesh

    2016-08-01

    Maintenance of large number of zebrafish in captive conditions is a daunting task. This can be eased by the use of recirculating racks with self-cleaning zebrafish tanks. Commercially available systems are costly, and compatibility of intercompany products has never been investigated. Although various cost-effective designs and methods of construction of custom-made recirculating zebrafish racks are available in literature, the design of self-cleaning zebrafish tanks is still not available. In this study, we report the design and method of construction of the self-cleaning unit, which can be fitted in any zebrafish tank. We validated the design by investigating sediment cleaning process in rectangular and cylindrical tank geometries using time lapse imaging. Our results suggest that for both tank geometries, the tanks fitted with self-cleaning unit provided superior sediment cleaning than the tanks fitted with overflow-drain unit. Although the self-cleaning unit could clean the sediment completely from both geometries over prolonged period, the cleaning of sediments was faster in the cylindrical tank than the rectangular tank. In conclusion, cost and efforts of zebrafish maintenance could be significantly reduced through the installation of our self-cleaning unit in any custom-made zebrafish tank.

  1. Fast mean and variance computation of the diffuse sound transmission through finite-sized thick and layered wall and floor systems

    NASA Astrophysics Data System (ADS)

    Decraene, Carolina; Dijckmans, Arne; Reynders, Edwin P. B.

    2018-05-01

    A method is developed for computing the mean and variance of the diffuse field sound transmission loss of finite-sized layered wall and floor systems that consist of solid, fluid and/or poroelastic layers. This is achieved by coupling a transfer matrix model of the wall or floor to statistical energy analysis subsystem models of the adjacent room volumes. The modal behavior of the wall is approximately accounted for by projecting the wall displacement onto a set of sinusoidal lateral basis functions. This hybrid modal transfer matrix-statistical energy analysis method is validated on multiple wall systems: a thin steel plate, a polymethyl methacrylate panel, a thick brick wall, a sandwich panel, a double-leaf wall with poro-elastic material in the cavity, and a double glazing. The predictions are compared with experimental data and with results obtained using alternative prediction methods such as the transfer matrix method with spatial windowing, the hybrid wave based-transfer matrix method, and the hybrid finite element-statistical energy analysis method. These comparisons confirm the prediction accuracy of the proposed method and the computational efficiency against the conventional hybrid finite element-statistical energy analysis method.

  2. Characterization of Laser Cleaning of Artworks

    PubMed Central

    Marczak, Jan; Koss, Andrzej; Targowski, Piotr; Góra, Michalina; Strzelec, Marek; Sarzyński, Antoni; Skrzeczanowski, Wojciech; Ostrowski, Roman; Rycyk, Antoni

    2008-01-01

    The main tasks of conservators of artworks and monuments are the estimation and analysis of damages (present condition), object conservation (cleaning process), and the protection of an object against further degradation. One of the physical methods that is becoming more and more popular for dirt removal is the laser cleaning method. This method is non-contact, selective, local, controlled, self-limiting, gives immediate feedback and preserves even the gentlest of relief - the trace of a paintbrush. Paper presents application of different, selected physical sensing methods to characterize condition of works of art as well as laser cleaning process itself. It includes, tested in our laboratories, optical surface measurements (e.g. colorimetry, scatterometry, interferometry), infrared thermography, optical coherent tomography and acoustic measurements for “on-line” evaluation of cleaning progress. Results of laser spectrometry analyses (LIBS, Raman) will illustrate identification and dating of objects superficial layers. PMID:27873884

  3. Evaluation of lumbar overload in hotel maids.

    PubMed

    Silva, J S; Correa, L R C; Morrone, L C

    2012-01-01

    Work-related musculoskeletal disorders are responsible for important amount of declining productivity among workers. Its economic impact is considered important because, in some aspects, such as sickness absence, it can cause increase in costs for employers. This paper aimed at identifying whether the activities that the hotel maids perform during working hours may lead to the development of musculoskeletal disorders. Cross-sectional study conducted in a hotel in the city of São Paulo, Brazil. Performed an ergonomic analysis of the job application with a checklist consisting of risk assessment of low back pain. The maids are responsible for the cleaning of hotel rooms, including to lean in order to clean the bathroom. The activity is associated with ergonomic risk for poor posture, manual transport of loads and use of physical force in the upper limbs. This job presents a moderate risk of low back pain according to checklist for assessing the ergonomic situation. Negative ergonomic aspects are associated with the development or aggravation of musculoskeletal disorders in these workers. We suggest modification in work organisation. Another possibility is decreased the weight of the carts, keeping areas of replacement material on each floor.

  4. Genitalic autogrooming: a self-filling trash collection system in crickets

    NASA Astrophysics Data System (ADS)

    Kumashiro, M.; Tsuji, Y.; Sakai, M.

    2006-02-01

    Insects groom almost all parts of the body surface with their legs and mouth parts. However, some body regions are difficult to reach and keep clean. One is the genital chamber located in the last abdominal segment in males which houses the phallic complex for copulation and production of the spermatophore. In the male cricket, foreign substances can enter the genital chamber when it is opened during copulation and spermatophore formation. Moreover, the dorsal pouch and ventral lobes of the phallic complex, which mould the attachment plate, tube, and ampulla of the spermatophore, are inevitably soiled as a result of spermatophore production. We found a unique cleaning system in which foreign substances accumulated during copulation and spermatophore debris left in the dorsal pouch after copulation are quickly removed and collected in special pockets in the genital chamber. This trash is collected by undulation of the genital chamber’s membranous floor which is entirely covered by small scales (˜10 μm) similar to those in the ovipositor of female crickets. This self-filling trash collecting system may be used in some other insects which produce the spermatophore in a similar manner to that of crickets.

  5. Campylobacter jejuni survival in a poultry processing plant environment.

    PubMed

    García-Sánchez, Lourdes; Melero, Beatriz; Jaime, Isabel; Hänninen, Marja-Liisa; Rossi, Mirko; Rovira, Jordi

    2017-08-01

    Campylobacteriosis is the most common cause of bacterial gastroenteritis worldwide. Consumption of poultry, especially chicken's meat is considered the most common route for human infection. The aim of this study was to determine if Campylobacter spp. might persist in the poultry plant environment before and after cleaning and disinfection procedures and the distribution and their genetic relatedness. During one month from a poultry plant were analyzed a total of 494 samples -defeathering machine, evisceration machine, floor, sink, conveyor belt, shackles and broiler meat- in order to isolate C. jejuni and C. coli. Results showed that C. jejuni and C. coli prevalence was 94.5% and 5.5% respectively. Different typing techniques as PFGE, MLST established seven C. jejuni genotypes. Whole genome MLST strongly suggest that highly clonal populations of C. jejuni can survive in adverse environmental conditions, even after cleaning and disinfection, and persist for longer periods than previous thought (at least 21 days) in the poultry plant environment. Even so, it might act as a source of contamination independently of the contamination level of the flock entering the slaughter line. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. [Pelvic floor and pregnancy].

    PubMed

    Fritel, X

    2010-05-01

    Congenital factor, obesity, aging, pregnancy and childbirth are the main risk factors for female pelvic floor disorders (urinary incontinence, anal incontinence, pelvic organ prolapse, dyspareunia). Vaginal delivery may cause injury to the pudendal nerve, the anal sphincter, or the anal sphincter. However the link between these injuries and pelvic floor symptoms is not always determined and we still ignore what might be the ways of prevention. Of the many obstetrical methods proposed to prevent postpartum symptoms, episiotomy, delivery in vertical position, delayed pushing, perineal massage, warm pack, pelvic floor rehabilitation, results are disappointing or limited. Caesarean section is followed by less postnatal urinary incontinence than vaginal childbirth. However this difference tends to disappear with time and following childbirth. Limit the number of instrumental extractions and prefer the vacuum to forceps could reduce pelvic floor disorders after childbirth. Ultrasound examination of the anal sphincter after a second-degree perineal tear is useful to detect and repair infra-clinic anal sphincter lesions. Scientific data is insufficient to justify an elective cesarean section in order to avoid pelvic floor symptoms in a woman without previous disorders. Copyright 2010 Elsevier Masson SAS. All rights reserved.

  7. Performance of Radiant Heating Systems of Low-Energy Buildings

    NASA Astrophysics Data System (ADS)

    Sarbu, Ioan; Mirza, Matei; Crasmareanu, Emanuel

    2017-10-01

    After the introduction of plastic piping, the application of water-based radiant heating with pipes embedded in room surfaces (i.e., floors, walls, and ceilings), has significantly increased worldwide. Additionally, interest and growth in radiant heating and cooling systems have increased in recent years because they have been demonstrated to be energy efficient in comparison to all-air distribution systems. This paper briefly describes the heat distribution systems in buildings, focusing on the radiant panels (floor, wall, ceiling, and floor-ceiling). Main objective of this study is the performance investigation of different types of low-temperature heating systems with different methods. Additionally, a comparative analysis of the energy, environmental, and economic performances of floor, wall, ceiling, and floor-ceiling heating using numerical simulation with Transient Systems Simulation (TRNSYS) software is performed. This study showed that the floor-ceiling heating system has the best performance in terms of the lowest energy consumption, operation cost, CO2 emission, and the nominal boiler power. The comparison of the room operative air temperatures and the set-point operative air temperature indicates also that all radiant panel systems provide satisfactory results without significant deviations.

  8. Management of disorders of the posterior pelvic floor.

    PubMed Central

    Berman, Loren; Aversa, John; Abir, Farshad; Longo, Walter E.

    2005-01-01

    INTRODUCTION: Constipation is a relatively common problem affecting 15 percent of adults in the Western world, and over half of these cases are related to pelvic floor disorders. This article reviews the clinical presentation and diagnostic approach to posterior pelvic floor disorders, including how to image and treat them. METHODS: A Pubmed search using keywords "rectal prolapse," "rectocele," "perineal hernia," and "anismus" was performed, and bibliographies of the revealed articles were cross-referenced to obtain a representative cross-section of the literature, both investigational studies and reviews, that are currently available on posterior pelvic floor disorders. DISCUSSION: Pelvic floor disorders can occur with or without concomitant physical anatomical defects, and there are a number of imaging modalities available to detect such abnormalities in order to decide on the appropriate course of treatment. Depending on the nature of the disorder, operative or non-operative therapy may be indicated. CONCLUSION: Correctly diagnosing pelvic floor disorders can be complex and challenging, and the various imaging modalities as well as clinical history and exam must be considered together in order to arrive at a diagnosis. PMID:16720016

  9. Physico-Chemical Dynamics of Nanoparticle Formation during Laser Decontamination

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cheng, M.D.

    2005-06-01

    Laser-ablation based decontamination is a new and effective approach for simultaneous removal and characterization of contaminants from surfaces (e.g., building interior and exterior walls, ground floors, etc.). The scientific objectives of this research are to: (1) characterize particulate matter generated during the laser-ablation based decontamination, (2) develop a technique for simultaneous cleaning and spectroscopic verification, and (3) develop an empirical model for predicting particle generation for the size range from 10 nm to tens of micrometers. This research project provides fundamental data obtained through a systematic study on the particle generation mechanism, and also provides a working model for predictionmore » of particle generation such that an effective operational strategy can be devised to facilitate worker protection.« less

  10. [Hygienic assessment of a recirculatory combined air-conditioning extract-and-input system in office building].

    PubMed

    Malysheva, A G; Abramov, E G

    2006-01-01

    The high concentrations of lead were reveled in the air and dust of some premises and on the filters of a combined air-conditioning extract-and-input system in the high-rise office buildings located in the ecologically lead favorable environment. The dust content of lead in some premises on the first floors dust was as high as 200 mg/kg, which was more than 6 times higher than that in the soil at the highway near the office buildings. The use of new technologies and devices for cleaning and optimizing the air in the premises requires analytical studies to assess the quality of the environment, by taking into account the optimal conditions of their operation.

  11. Assessment of disinfection of hospital surfaces using different monitoring methods1

    PubMed Central

    Ferreira, Adriano Menis; de Andrade, Denise; Rigotti, Marcelo Alessandro; de Almeida, Margarete Teresa Gottardo; Guerra, Odanir Garcia; dos Santos, Aires Garcia

    2015-01-01

    OBJECTIVE: to assess the efficiency of cleaning/disinfection of surfaces of an Intensive Care Unit. METHOD: descriptive-exploratory study with quantitative approach conducted over the course of four weeks. Visual inspection, bioluminescence adenosine triphosphate and microbiological indicators were used to indicate cleanliness/disinfection. Five surfaces (bed rails, bedside tables, infusion pumps, nurses' counter, and medical prescription table) were assessed before and after the use of rubbing alcohol at 70% (w/v), totaling 160 samples for each method. Non-parametric tests were used considering statistically significant differences at p<0.05. RESULTS: after the cleaning/disinfection process, 87.5, 79.4 and 87.5% of the surfaces were considered clean using the visual inspection, bioluminescence adenosine triphosphate and microbiological analyses, respectively. A statistically significant decrease was observed in the disapproval rates after the cleaning process considering the three assessment methods; the visual inspection was the least reliable. CONCLUSION: the cleaning/disinfection method was efficient in reducing microbial load and organic matter of surfaces, however, these findings require further study to clarify aspects related to the efficiency of friction, its frequency, and whether or not there is association with other inputs to achieve improved results of the cleaning/disinfection process. PMID:26312634

  12. The Combine Use of Semi-destructive and Non-destructive Methods for Tiled Floor Diagnostics

    NASA Astrophysics Data System (ADS)

    Štainbruch, Jakub; Bayer, Karol; Jiroušek, Tomáš; Červinka, Josef

    2017-04-01

    The combination of semi-destructive and non-destructive methods was used to asset the conditions of a tiled floor in the historical monument Minaret, situated in the park complex of the Chateau Lednice (South Moravia Region, Czech Republic), before its renovation. Another set of measurements is going to be performed after the conservation works are finished. (The comparison of the results collected during pre- and post-remediation measurements will be known and presented during the General Assembly meeting in Wien.) The diagnostic complex of methods consisted of photogrammetry, resistivity drilling and georadar. The survey was aimed to contour extends of air gaps beneath the tiles and the efficiency of filling gaps by means of injection, consolidation and gluing individual layers. The state chateau Lednice creates a part of the Lednice-Valtice precinct, a UNESCO landmark, and belongs among the greatest historic monuments in Southern Moravia. In the chateau park there is a romantic observation tower in the shape of a minaret built according to the plans of Josef Hardtmuth between 1798-1804. The Minaret has been extensively renovated for many decades including the restoration of mosaic floors from Venetian terazzo. During the static works of the Minaret building between 1999-2000, the mosaic floors in the rooms on the second floor were transferred and put back onto concrete slabs. Specifically, the floor was cut up to tiles and these were glued to square slabs which were then attached to the base plate. The transfer was not successful and the floor restoration was finalized between 2016-2017. The damage consisted in separating the original floor from the concrete plate which led to creating gaps. Furthermore, the layers of the floor were not compact. It was necessary to fill the gaps and consolidate and glue the layers. The existence of air gap between individual layers of the tiles and their degradation was detected using two different diagnostic methods: semi-destructive resistivity drilling, and non-destructive georadar, and the results were compared. Floors were measured by 3D laser scanning technology and captured by the camera before reconstruction work. Using SFM photogrammetry were achieved results: ortomozaik (0.3 mm / pix) and DEM (0.6 mm / pix). These results were a basis for restoration work and also allow comparisons with the original state at any stage of the project. Drilling resistance measurement is used for indirect determination of strength profile based on resistance to drilling depending on into the depth. The observed resistance to drilling correlates with the strength and toughness of the measured material. The method is referred as a micro- or semi-invasive, since sampling is not necessary and but the drilling diameter is usually 3-5 mm. The ultrasonic measurement consists in the measuring of the longitude as well as the transverse waves - velocity, shape, amplitude. The propagation velocity is a characteristic values for the material influenced by its composition and compactness. Georadar (GPR) is a high frequency electromagnetic pulse method. For measurement the GPR RAMAC system coupled with 1600 MHz shielded antenna was used. Two tiles (one with defects and one in relatively good condition) were surveyed in a regular grid of perpendicular lines 5 cm separated. Data were processed by means of ReflexW software and performed in the form of cross sections and amplitude maps. The map of the amplitude summed over a time window 1 - 1,4 ns (representing the intensity of the reflection from the tiles bottom) gave good result. The areas of registered relatively high amplitudes correspond with the position of airgaps. A correlation was observed between the results of different survey methods.

  13. Characterization of occupational exposures to cleaning products used for common cleaning tasks--a pilot study of hospital cleaners.

    PubMed

    Bello, Anila; Quinn, Margaret M; Perry, Melissa J; Milton, Donald K

    2009-03-27

    In recent years, cleaning has been identified as an occupational risk because of an increased incidence of reported respiratory effects, such as asthma and asthma-like symptoms among cleaning workers. Due to the lack of systematic occupational hygiene analyses and workplace exposure data, it is not clear which cleaning-related exposures induce or aggravate asthma and other respiratory effects. Currently, there is a need for systematic evaluation of cleaning products ingredients and their exposures in the workplace. The objectives of this work were to: a) identify cleaning products' ingredients of concern with respect to respiratory and skin irritation and sensitization; and b) assess the potential for inhalation and dermal exposures to these ingredients during common cleaning tasks. We prioritized ingredients of concern in cleaning products commonly used in several hospitals in Massachusetts. Methods included workplace interviews, reviews of product Materials Safety Data Sheets and the scientific literature on adverse health effects to humans, reviews of physico-chemical properties of cleaning ingredients, and occupational hygiene observational analyses. Furthermore, the potential for exposure in the workplace was assessed by conducting qualitative assessment of airborne exposures and semi-quantitative assessment of dermal exposures. Cleaning products used for common cleaning tasks were mixtures of many chemicals, including respiratory and dermal irritants and sensitizers. Examples of ingredients of concern include quaternary ammonium compounds, 2-butoxyethanol, and ethanolamines. Cleaning workers are at risk of acute and chronic inhalation exposures to volatile organic compounds (VOC) vapors and aerosols generated from product spraying, and dermal exposures mostly through hands. Cleaning products are mixtures of many chemical ingredients that may impact workers' health through air and dermal exposures. Because cleaning exposures are a function of product formulations and product application procedures, a combination of product evaluation with workplace exposure assessment is critical in developing strategies for protecting workers from cleaning hazards. Our task based assessment methods allowed classification of tasks in different exposure categories, a strategy that can be employed by epidemiological investigations related to cleaning. The methods presented here can be used by occupational and environmental health practitioners to identify intervention strategies.

  14. Long-term effects of seven cleaning methods on light transmittance, surface roughness, and flexural modulus of polyurethane retainer material.

    PubMed

    Agarwal, Manika; Wible, Emily; Ramir, Tyler; Altun, Sibel; Viana, Grace; Evans, Carla; Lukic, Henry; Megremis, Spiro; Atsawasuwan, Phimon

    2018-05-01

    To evaluate the long-term effects of seven different cleaning methods on light transmittance, surface roughness, and flexural modulus of a polyurethane retainer material. Polyurethane retainer specimens (Vivera®, Align Technology Inc) (70 specimens, n = 10 per method, 50.8 mm × 12.7 mm × 1.0 mm) were exposed to seven cleaning methods twice a week for 6 months. Before treatment and after 6 months, light transmittance, surface roughness, and flexural modulus of the specimens were quantified. Qualitative assessment of randomly selected specimens from each solution was performed at baseline and after 6 months using a scanning electron microscope. Statistical analyses were performed at the .05 significance level. Of the three test variables, light transmittance through the specimens was the only one that changed significantly from baseline to 6 months for all cleaning solutions, with all of them causing a decrease. However, except for 0.6% sodium hypochlorite showing a change in surface roughness values and 2.5% vinegar and toothbrushing showing an increase in flexural modulus, none of the other four cleaning methods resulted in significant changes in surface roughness or flexural modulus values for the polyurethane specimens between baseline and after 6 months. Of the seven cleaning methods, Invisalign® cleaning crystals, Polident®, and Listerine® showed the least amount of change in light transmittance values for the polyurethane specimens over 6 months, and they had no effect on surface roughness and flexural modulus values.

  15. 75 FR 51807 - Science Advisory Board Staff Office; Notification of a Public Teleconference of the Clean Air...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-23

    ... a Public Teleconference of the Clean Air Scientific Advisory Committee (CASAC) Ambient Air Methods... announcing a public teleconference on September 15, 2010, of the Clean Air Scientific Advisory Committee (CASAC) Ambient Air Monitoring & Methods Subcommittee (AAMMS or Subcommittee) to provide advice on EPA's...

  16. Method for removing metals from a cleaning solution

    DOEpatents

    Deacon, Lewis E.

    2002-01-01

    A method for removing accumulated metals from a cleaning solution is provided. After removal of the metals, the cleaning solution can be discharged or recycled. The process manipulates the pH levels of the solution as a means of precipitating solids. Preferably a dual phase separation at two different pH levels is utilized.

  17. Alternative Chemical Cleaning Methods for High Level Waste Tanks: Simulant Studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rudisill, T.; King, W.; Hay, M.

    Solubility testing with simulated High Level Waste tank heel solids has been conducted in order to evaluate two alternative chemical cleaning technologies for the dissolution of sludge residuals remaining in the tanks after the exhaustion of mechanical cleaning and sludge washing efforts. Tests were conducted with non-radioactive pure phase metal reagents, binary mixtures of reagents, and a Savannah River Site PUREX heel simulant to determine the effectiveness of an optimized, dilute oxalic/nitric acid cleaning reagent and pure, dilute nitric acid toward dissolving the bulk non-radioactive waste components. A focus of this testing was on minimization of oxalic acid additions duringmore » tank cleaning. For comparison purposes, separate samples were also contacted with pure, concentrated oxalic acid which is the current baseline chemical cleaning reagent. In a separate study, solubility tests were conducted with radioactive tank heel simulants using acidic and caustic permanganate-based methods focused on the “targeted” dissolution of actinide species known to be drivers for Savannah River Site tank closure Performance Assessments. Permanganate-based cleaning methods were evaluated prior to and after oxalic acid contact.« less

  18. Otolith Trace Element Chemistry of Juvenile Black Rockfish

    NASA Astrophysics Data System (ADS)

    Hardin, W.; Bobko, S. J.; Jones, C. M.

    2002-12-01

    In the summer of 1997 we collected young-of -the-year (YOY) black rockfish, Sebastes melanops, from floating docks and seagrass beds in Newport and Coos Bay, Oregon. Otoliths were extracted from randomly selected fish, sectioned and polished under general laboratory conditions, and cleaned in a class 100 clean room. We used Laser Ablation - Inductively Coupled Mass Spectrometry (LA-ICPMS) to analyze elemental composition of the estuarine phase of the otoliths. While we observed differences in Mn/Ca ratios between the two estuaries, there was no statistical difference in otolith trace element chemistry ratios between estuaries using MANOVA. To determine if laboratory processing of otoliths might have impeded us from detecting differences in otolith chemistry, we conducted a second experiment. Right and left otoliths from 10 additional Coos Bay fish were randomly allocated to two processing methods. The first method was identical to our initial otolith processing, sectioning and polishing under normal laboratory conditions. In the second method, polishing was done in the clean room. For both methods otoliths went through a final cleaning in the clean room and analyzed with LA-ICPMS. While we did not detect statistical differences in element ratios between the two methods, otoliths polished outside the clean room had much higher variances. This increased variance might have lowered our ability to detect differences in otolith chemistry between estuaries. Based on our results, we recommend polishing otoliths under clean room conditions to reduce contamination.

  19. Trade study comparing specimen chamber servicing methods for the Space Station Centrifuge Facility

    NASA Technical Reports Server (NTRS)

    Calvisi, Michael L.; Sun, Sidney C.

    1991-01-01

    The Specimen Chamber Service Unit, a component of the Space Station Centrifuge Facility, must provide a clean enclosure on a continuing basis for the facility's plant, rodent and primate specimens. The specimen chambers can become soiled and can require periodic servicing to maintain a clean environment for the specimens. Two methods of servicing the specimen chambers are discussed: washing the chambers with an on-board washer, or disposing of the soiled chambers and replacing them with clean ones. Many of these issues are addressed by developing several servicing options, using either cleaning or replacement as the method of providing clean specimen chambers, and then evaluating each option according to a set of established quantitative and qualitative criteria. Disposing and replacing the Specimen Chambers is preferable to washing them.

  20. Effects of cleaning methods upon preservation of stable isotopes and trace elements in shells of Cyprideis torosa (Crustacea, Ostracoda): Implications for palaeoenvironmental reconstruction

    NASA Astrophysics Data System (ADS)

    Roberts, L. R.; Holmes, J. A.; Leng, M. J.; Sloane, H. J.; Horne, D. J.

    2018-06-01

    The trace element (Sr/Ca and Mg/Ca) and stable isotope (δ18O and δ13C) geochemistry of fossil ostracod valves provide valuable information, particularly in lacustrine settings, on palaeo-water composition and palaeotemperature. The removal of sedimentary and organic contamination prior to geochemical analysis is essential to avoid bias of the results. Previous stable isotope and trace element work on ostracod shells has, however, employed different treatments for the removal of contamination beyond simple 'manual' cleaning using a paint brush and methanol under a low-power binocular microscope. For isotopic work pre-treatments include chemical oxidation, vacuum roasting and plasma ashing, and for trace element work sonication, chemical oxidation and reductive cleaning. The impact of different treatments on the geochemical composition of the valve calcite has not been evaluated in full, and a universal protocol has not been established. Here, a systematic investigation of the cleaning methods is undertaken using specimens of the ubiquitous euryhaline species, Cyprideis torosa. Cleaning methods are evaluated by undertaking paired analyses on a single carapace (comprising two valves); in modern ostracods, whose valves are assumed to be unaltered, the two valves should have identical geochemical and isotopic composition. Hence, when one valve is subjected to the chosen treatment and the other to simple manual cleaning any difference in composition can confidently be assigned to the treatment method. We show that certain cleaning methods have the potential to cause alteration to the geochemical signal, particularly Mg/Ca and δ18O, and hence have implications for palaeoenvironmental reconstructions. For trace-element determinations we recommend cleaning by sonication and for stable isotope analysis, oxidation by hydrogen peroxide. These methods remove contamination, yet do not significantly alter the geochemical signal.

  1. Improved repeatability of nasal potential difference with a larger surface catheter.

    PubMed

    Vermeulen, François; Proesmans, Marijke; Boon, Mieke; De Boeck, Kris

    2015-05-01

    To increase the power of nasal potential difference (NPD) as a biomarker of CFTR function, improvement of its repeatability is needed. We evaluated the improvement in repeatability resulting from measuring NPD (1) over a larger surface area and (2) at a fixed location. To assess repeatability, NPD was measured on two occasions with a new method using a larger surface catheter at fixed locations on the nasal floor (LSC-floor(5cm) and LSC-floor(3cm)) or at the most negative basal potential (LSC-floor(max)); with a sidehole catheter on the nasal floor at 5 cm) from the nasal margin (SHC-floor(5cm)) or at the most negative potential (SHC-floor(max)); and with an endhole catheter below the inferior surface of the lower turbinate at the most negative potential (EHC-turb(max)). The within-subject standard deviation (S(w)) for repeated measurements of the total chloride response in the controls was smallest with the LSC-floor at a fixed location (LSC-floor(5cm) 3.1 mV; 95% CI 2.3-4.6 mV) and highest with the SHC-floor (SHC-floor(max) 14.6 mV; 95% CI 10.9-22.2 mV) or the EHC-turbinate (EHC-turb(max) 12.5 mV; 95% CI 10.7-23.0 mV) at the most negative basal potential. Measuring with the LSC-floor at the maximal potential increased the Sw (LSC-floor(max) 8.8 mV, 95% CI 6.0-16.1 mV, p=0.009 vs LSC-floor(5cm)), while measuring with the SHC-floor at a fixed location slightly decreased the Sw (SHC-floor(5cm) 9.8 mV, 95% CI 8.9-20.6 mV, p=0.06 vs SHC-floor(max)). In patients with cystic fibrosis, the S(w) was comparable, between 2.2 mV and 4.3 mV. Sample size calculations for trials using NPD to assess changes in ion transport showed that the number of subjects to be included could be approximately halved measuring with the larger surface catheter at a fixed location vs SHC or EHC at fixed locations. Measuring the NPD at a fixed location and over a larger surface resulted in increased repeatability and thereby also power as a biomarker of CFTR modulation. Copyright © 2014 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  2. Comparison of environmental and egg microbiology associated with conventional and free-range laying hen management.

    PubMed

    Jones, D R; Anderson, K E; Musgrove, M T

    2011-09-01

    Eggs from alternative production practices are a growing niche in the market. Meeting consumer requests for greater diversity in retail egg options has resulted in some unique challenges such as understanding the food safety implications of eggs from alternative production practices. A study was conducted to determine what, if any, differences exist between nest run conventional cage-produced eggs and free range-produced eggs. A sister flock of brown egg layers was maintained in conventional cage and free-range production with egg and environmental sampling every 6 wk from 20 to 79 wk of age. Aerobic, coliform, and yeast and mold populations were monitored. Environmental microbial levels were not always indicative of egg contamination levels. When significant differences (P < 0.05 and P < 0.0001, dependent on season) were observed among treatments for coliforms, shell contamination levels of free-range nest box eggs and free-range floor eggs were always greater than those of conventional cage eggs, which remained low throughout the study (0.42-0.02 log cfu/mL). Shell yeast and mold levels were significantly greater in free-range floor eggs than in free-range nest box eggs and conventional cage eggs throughout the entire study. Egg contents contamination levels were extremely low for all monitored populations and treatments. Season of the year played a role in both environmental and egg microbial levels. Winter had the lowest levels of all populations monitored for all treatments, except for aerobic free-range floor egg shell emulsions, which were increased (3.6 log cfu/mL). Understanding the differences in microbial populations present on conventional cage-produced and free range-produced eggs can lead to the development of effective cleaning procedures, enhancing food safety.

  3. Enhanced Detection of Surface-Associated Bacteria in Indoor Environments by Quantitative PCR

    PubMed Central

    Buttner, Mark P.; Cruz-Perez, Patricia; Stetzenbach, Linda D.

    2001-01-01

    Methods for detecting microorganisms on surfaces are needed to locate biocontamination sources and to relate surface and airborne concentrations. Research was conducted in an experimental room to evaluate surface sampling methods and quantitative PCR (QPCR) for enhanced detection of a target biocontaminant present on flooring materials. QPCR and culture analyses were used to quantitate Bacillus subtilis (Bacillus globigii) endospores on vinyl tile, commercial carpet, and new and soiled residential carpet with samples obtained by four surface sampling methods: a swab kit, a sponge swipe, a cotton swab, and a bulk method. The initial data showed that greater overall sensitivity was obtained with the QPCR than with culture analysis; however, the QPCR results for bulk samples from residential carpet were negative. The swab kit and the sponge swipe methods were then tested with two levels of background biological contamination consisting of Penicillium chrysogenum spores. The B. subtilis values obtained by the QPCR method were greater than those obtained by culture analysis. The differences between the QPCR and culture data were significant for the samples obtained with the swab kit for all flooring materials except soiled residential carpet and with the sponge swipe for commercial carpet. The QPCR data showed that there were no significant differences between the swab kit and sponge swipe sampling methods for any of the flooring materials. Inhibition of QPCR due solely to biological contamination of flooring materials was not evident. However, some degree of inhibition was observed with the soiled residential carpet, which may have been caused by the presence of abiotic contaminants, alone or in combination with biological contaminants. The results of this research demonstrate the ability of QPCR to enhance detection and enumeration of biocontaminants on surface materials and provide information concerning the comparability of currently available surface sampling methods. PMID:11375164

  4. Surface chemistry of a pine-oil cleaner and other terpene mixtures with ozone on vinyl flooring tiles.

    PubMed

    Ham, Jason E; Wells, J Raymond

    2011-04-01

    Indoor environments are dynamic reactors where consumer products (such as cleaning agents, deodorants, and air fresheners) emit volatile organic compounds (VOCs) that can subsequently interact with indoor oxidants such as ozone (O(3)), hydroxyl radicals, and nitrate radicals. Typically, consumer products consist of mixtures of VOCs and semi-VOCs which can react in the gas-phase or on surfaces with these oxidants to generate a variety of oxygenated products. In this study, the reaction of a pine-oil cleaner (POC) with O(3) (100ppb) on a urethane-coated vinyl flooring tile was investigated at 5% and 50% relative humidity. These results were compared to previous α-terpineol+O(3) reactions on glass and vinyl surfaces. Additionally, other terpene and terpene alcohol mixtures were formulated to understand the emission profiles as seen in the POC data. Results showed that the α-terpineol+O(3) reaction products were the prominent species that were also observed in the POC/O(3) surface experiments. Furthermore, α-terpineol+O(3) reactions generate the largest fraction of oxygenated products even in equal mixtures of other terpene alcohols. This finding suggests that the judicial choice of terpene alcohols for inclusion in product formulations may be useful in reducing oxidation product emissions. Published by Elsevier Ltd.

  5. EVALUATION OF TWO CLEANING METHODS FOR THE REMOVAL OF ASBESTOS FIBERS FROM CARPET

    EPA Science Inventory

    This research study examined the effectiveness of dry vacuuming and wet cleaning for the removal of asbestos fibers from carpet, and evaluated the potential for fiber reentrainment during carpet cleaning activities. outine carpet cleaning operations using high-efficiency particul...

  6. Pelvic floor muscle strength of women consulting at the gynecology outpatient clinics and its correlation with sexual dysfunction: A cross-sectional study.

    PubMed

    Ozdemir, Filiz Ciledag; Pehlivan, Erkan; Melekoglu, Rauf

    2017-01-01

    To investigate the pelvic floor muscle strength of the women andevaluateits possible correlation with sexual dysfunction. In this cross-sectional type study, stratified clusters were used for the sampling method. Index of Female Sexual Function (IFSF) worksheetwere used for questions on sexual function. The pelvic floor muscle strength of subjects was assessed byperineometer. The chi-squared test, logistic regression and Pearson's correlation analysis were used for the statistical analysis. Four hundred thirty primiparous women, mean age 38.5 participated in this study. The average pelvic floor muscle strength value was found 31.4±9.6 cm H 2 O and the average Index of Female Sexual Function (IFSF) score was found 26.5±6.9. Parity (odds ratio OR=5.546) and age 40 or higher (OR=3.484) were found correlated with pelvic floor muscle weakness (p<0.05). The factors directly correlated with sexual dysfunction were found being overweight (OR=2.105) and age 40 or higher (OR=2.451) (p<0.05). Pearson's correlation analysis showed that there was a statistically significantlinear correlation between the muscular strength of the pelvic floor and sexual function (p=0.001). The results suggested subjects with decreased pelvic floor muscle strength value had higher frequency of sexual dysfunction.

  7. Vibrating vaginal balls to improve pelvic floor muscle performance in women after childbirth: a protocol for a randomised controlled feasibility trial.

    PubMed

    Oblasser, Claudia; McCourt, Christine; Hanzal, Engelbert; Christie, Janice

    2016-04-01

    This paper presents a feasibility trial protocol the purpose of which is to prepare for a future randomised controlled trial to determine the effectiveness of vibrating vaginal pelvic floor training balls for postpartum pelvic floor muscle rehabilitation. Vibrating vaginal pelvic floor training balls are available in Austria to enhance women's pelvic floor muscles and thus prevent or treat urinary incontinence and other pelvic floor problems following childbirth. Nonetheless, there is currently little empirical knowledge to substantiate their use or assess their relative effectiveness in comparison to current standard care, which involves pelvic floor muscle exercises. Single blind, randomised controlled feasibility trial with two parallel groups. It is planned to recruit 56 postpartum women in Vienna, who will be randomised into one of two intervention groups to use either vibrating vaginal balls or a comparator pelvic floor muscle exercises for 12 weeks. As this is a feasibility study, study design features (recruitment, selection, randomisation, intervention concordance, data collection methods and tools) will be assessed and participants' views and experiences will be surveyed. Tested outcome measures, collected before and after the intervention, will be pelvic floor muscle performance as reported by participants and measured by perineometry. Descriptive and inferential statistics and content analysis will serve the preparation of the future trial. The results of this feasibility trial will inform the design and conduct of a full randomised controlled trial and provide insight into the experiences of women regarding the interventions and study participation. © 2015 John Wiley & Sons Ltd.

  8. Method for cleaning and passivating a metal surface

    NASA Technical Reports Server (NTRS)

    Alexander, George B. (Inventor); Carpenter, Norman F. (Inventor)

    1976-01-01

    A cleaning solvent useful in the cleaning of metal surfaces, e.g. nickle-iron alloys, contains sulfamic acid, citric acid, a solvent for hydrocarbon residues, and a surfactant. Metal surfaces are cleaned by contacting the surface with the cleaning solvent and then passivated by contact with aqueous solutions of citric acid or sodium nitrite or a combination of the two.

  9. Validation of cleaning method for various parts fabricated at a Beryllium facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davis, Cynthia M.

    This study evaluated and documented a cleaning process that is used to clean parts that are fabricated at a beryllium facility at Los Alamos National Laboratory. The purpose of evaluating this cleaning process was to validate and approve it for future use to assure beryllium surface levels are below the Department of Energy’s release limits without the need to sample all parts leaving the facility. Inhaling or coming in contact with beryllium can cause an immune response that can result in an individual becoming sensitized to beryllium, which can then lead to a disease of the lungs called chronic berylliummore » disease, and possibly lung cancer. Thirty aluminum and thirty stainless steel parts were fabricated on a lathe in the beryllium facility, as well as thirty-two beryllium parts, for the purpose of testing a parts cleaning method that involved the use of ultrasonic cleaners. A cleaning method was created, documented, validated, and approved, to reduce beryllium contamination.« less

  10. Plasma discharge self-cleaning filtration system

    DOEpatents

    Cho, Young I.; Fridman, Alexander; Gutsol, Alexander F.; Yang, Yong

    2014-07-22

    The present invention is directed to a novel method for cleaning a filter surface using a plasma discharge self-cleaning filtration system. The method involves utilizing plasma discharges to induce short electric pulses of nanoseconds duration at high voltages. These electrical pulses generate strong Shockwaves that disintegrate and dislodge particulate matter located on the surface of the filter.

  11. Optimization of Typological Requirements for Low-Cost Detached Houses

    NASA Astrophysics Data System (ADS)

    Kuráň, Jozef

    2017-09-01

    The presented paper deals with an analysis of the legislative, hygienic, functional and operational requirements for the design of detached houses and individual dwellings in terms of typological requirements. The article also presents a sociological survey about the preferences and subjective requirements of relevant public group segments in terms of living in a detached house or an individual dwelling. The aim of the paper is to define the possibilities for the optimization of typological requirements. The optimization methods are based on principles already applied to contemporary detached house preferences and trends. The main idea is to reduce the amount of floor space, thus lowering construction and operating costs. The goal is to design an optimized floor plan, while preserving the hygienic criteria for individual residential dwellings. By applying optimization methods, a so-called rationalized and conditioned floor plan results in an individual dwelling floor plan design that can be compared to a reference model with an accurate quantification comparison. The significant sources of research are the legislative and normative requirements in the field of house construction in Slovakia, the Czech Republic and abroad.

  12. Quality Partners

    ERIC Educational Resources Information Center

    Clark, Bob

    2006-01-01

    Green cleaning is gaining momentum. It is a method of cleaning and maintaining facilities that is friendly to the environment and healthful for students and staff. The process uses environmentally friendly and nontoxic cleaning products and practices that must be third-party-certified. Using green cleaning practices and products can result in…

  13. Comparison of Musculoskeletal Disorder Health Claims Between Construction Floor Layers and a General Working Population

    PubMed Central

    Dale, Ann Marie; Ryan, Daniel; Welch, Laura; Olsen, Margaret A.; Buchholz, Bryan; Evanoff, Bradley

    2014-01-01

    Objectives Compare rates of medical insurance claims for musculoskeletal disorders (MSD) between workers in a construction trade and a general worker population to determine if higher physical exposures in construction lead to higher rates of claims on personal medical insurance. Methods Health insurance claims between 2006 and 2010 from floor layers were frequency matched by age, gender, eligibility time, and geographic location to claims from insured workers in general industry obtained from MarketScan. We extracted MSD claims and dates of service from six regions of the body: neck, low back, knee, lower extremity, shoulder, and distal arm, and evaluated differences in claim rates. Results Fifty-one percent of floor layers (n=1,475) experienced musculoskeletal claims compared to 39% of MarketScan members (p<0.001). Claim rates were higher for floor layers across all body regions with nearly double the rate ratios for the knee and neck regions (RR: 2.10 and 2.07). The excess risk was greatest for the neck and low back regions; younger workers had disproportionately higher rates in the knee, neck, low back, and distal arm. A larger proportion of floor layers (22%) filed MSD claims in more than one body region compared to general workers (10%; p<0.001). Conclusions Floor layers have markedly higher rates of MSD claims compared to a general worker population, suggesting shifting of medical costs for work-related MSD to personal health insurance. The occurrence of disorders in multiple body regions and among the youngest workers highlights the need for improved work methods and tools for construction workers. PMID:25224720

  14. Cleaning, disinfection and sterilization of surface prion contamination.

    PubMed

    McDonnell, G; Dehen, C; Perrin, A; Thomas, V; Igel-Egalon, A; Burke, P A; Deslys, J P; Comoy, E

    2013-12-01

    Prion contamination is a risk during device reprocessing, being difficult to remove and inactivate. Little is known of the combined effects of cleaning, disinfection and sterilization during a typical reprocessing cycle in clinical practice. To investigate the combination of cleaning, disinfection and/or sterilization on reducing the risk of surface prion contamination. In vivo test methods were used to study the impact of cleaning alone and cleaning combined with thermal disinfection and high- or low-temperature sterilization processes. A standardized test method, based on contamination of stainless steel wires with high titres of scrapie-infected brain homogenates, was used to determine infectivity reduction. Traditional chemical methods of surface decontamination against prions were confirmed to be effective, but extended steam sterilization was more variable. Steam sterilization alone reduced the risk of prion contamination under normal or extended exposure conditions, but did show significant variation. Thermal disinfection had no impact in these studies. Cleaning with certain defined formulations in combination with steam sterilization can be an effective prion decontamination process, in particular with alkaline formulations. Low-temperature, gaseous hydrogen peroxide sterilization was also confirmed to reduce infectivity in the presence and absence of cleaning. Prion decontamination is affected by the full reprocessing cycle used on contaminated surfaces. The correct use of defined cleaning, disinfection and sterilization methods as tested in this report in the scrapie infectivity assay can provide a standard precaution against prion contamination. Copyright © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  15. Grazing system and floor type effects on blood biochemistry, growth and carcass characteristics of Nguni goats

    PubMed Central

    Chikwanda, Allen Tapiwa; Muchenje, Voster

    2017-01-01

    Objective Purpose was to determine the effects of grazing system and floor type on concentrations of blood metabolites, activity of creatine kinase, body weight and carcass characteristics of castrated Nguni goats. Methods Forty eight, 7 month old goats were randomly allocated to herding and tethering treatments from 0800 to 1300 hours and accommodated on slatted and earth floors daily. Blood samples were collected by jugular venipuncture every fifteenth day for metabolite analysis. Slaughter was done at a commercial abattoir following 5 months of monitoring. Results Tethered goats had significantly higher concentrations of urea (5.19 mmol/L) (p< 0.001), creatinine (55.87 μmol/L) (p<0.05), total protein (64.60 g/L) (p<0.01), and globulin (49.79 g/L) (p<0.001), whereas herded goats had higher glucose (3.38 mmol/L) (p<0.001), albumin (15.33 g/L) (p<0.05), albumin/globulin ratio (0.34) (p<0.01), and body weight (24.87 kg) (p< 0.001). Slatted floors caused higher (p<0.01) albumin at 15.37 g/L. The interaction of grazing system and floor type affected creatinine, total protein, globulin at (p<0.01) and albumen/globulin ratio at (p<0.01). The least creatinine concentration and albumin/globulin ratio was in herded and tethered goats that were accommodated on earth floors, respectively. The highest total protein and globulin concentrations were in serum of tethered goats that were accommodated on earth floors. The highest (p<0.05) dressing percentage (45.26%) was in herded goats accommodated on slatted floors. Conclusion Herding of goats lowered globulin concentration, improved estimated feed intake, blood glucose and albumin concentrations, albumin globulin ratio, increased body weights and weight related carcass characteristics. Floor type had very little effects on metabolites where earth floors only reduced albumin concentration. Tethering and housing goats on earth floors resulted in double stress that increased chronic infections. PMID:28002930

  16. The effect of long or chopped straw on pig behaviour.

    PubMed

    Lahrmann, H P; Oxholm, L C; Steinmetz, H; Nielsen, M B F; D'Eath, R B

    2015-05-01

    In the EU, pigs must have permanent access to manipulable materials such as straw, rope, wood, etc. Long straw can fulfil this function, but can increase labour requirements for cleaning pens, and result in problems with blocked slatted floors and slurry systems. Chopped straw might be more practical, but what is the effect on pigs' behaviour of using chopped straw instead of long straw? Commercial pigs in 1/3 slatted, 2/3 solid pens of 15 pigs were provided with either 100 g/pig per day of long straw (20 pens) or of chopped straw (19 pens). Behavioural observations were made of three focal pigs per pen (one from each of small, medium and large weight tertiles) for one full day between 0600 and 2300 h at each of ~40 and ~80 kg. The time spent rooting/investigating overall (709 s/pig per hour at 40 kg to 533 s/pig per hour at 80 kg), or directed to the straw/solid floor (497 s/pig per hour at 40 kg to 343 s/pig per hour at 80 kg), was not affected by straw length but reduced with age. Time spent investigating other pigs (83 s/pig per hour at 40 kg), the slatted floor (57 s/pig per hour) or pen fixtures (21 s/pig per hour) was not affected by age or straw length. Aggressive behaviour was infrequent, but lasted about twice as long in pens with chopped straw (2.3 s/pig per hour at 40 kg) compared with pens with long straw (1.0 s/pig per hour at 40 kg, P=0.060). There were no significant effects of straw length on tail or ear lesions, but shoulders were significantly more likely to have minor scratches with chopped straw (P=0.031), which may reflect the higher levels of aggression. Smaller pigs showed more rooting/investigatory behaviour, and in particular directed towards the straw/solid floor and the slatted floor than their larger pen-mates. Females exhibited more straw and pen fixture-directed behaviour than males. There were no effects of pig size or sex on behaviour directed towards other pigs. In summary, pigs spent similar amounts of time interacting with straw/solid floor when long and chopped straw were provided, and most aspects of pig-directed behaviour and injuries were not affected by straw length. There was an increase in pigs with minor shoulder lesions with chopped straw, perhaps because of increased aggression. The use of chopped straw as an enrichment material for pigs warrants further investigation in larger and more detailed studies.

  17. The Integral Theory System Questionnaire: an anatomically directed questionnaire to determine pelvic floor dysfunctions in women.

    PubMed

    Wagenlehner, Florian Martin Erich; Fröhlich, Oliver; Bschleipfer, Thomas; Weidner, Wolfgang; Perletti, Gianpaolo

    2014-06-01

    Anatomical damage to pelvic floor structures may cause multiple symptoms. The Integral Theory System Questionnaire (ITSQ) is a holistic questionnaire that uses symptoms to help locate damage in specific connective tissue structures as a guide to reconstructive surgery. It is based on the integral theory, which states that pelvic floor symptoms and prolapse are both caused by lax suspensory ligaments. The aim of the present study was to psychometrically validate the ITSQ. Established psychometric properties including validity, reliability, and responsiveness were considered for evaluation. Criterion validity was assessed in a cohort of 110 women with pelvic floor dysfunctions by analyzing the correlation of questionnaire responses with objective clinical data. Test-retest was performed with questionnaires from 47 patients. Cronbach's alpha and "split-half" reliability coefficients were calculated for inner consistency analysis. Psychometric properties of ITSQ were comparable to the ones of previously validated Pelvic Floor Questionnaires. Face validity and content validity were approved by an expert group of the International Collaboration of Pelvic Floor surgeons. Convergent validity assessed using Bayesian method was at least as accurate as the expert assessment of anatomical defects. Objective data measurement in patients demonstrated significant correlations with ITSQ domains fulfilling criterion validity. Internal consistency values ranked from 0.85 to 0.89 in different scenarios. The ITSQ proofed accurate and is able to serve as a holistic Pelvic Floor Questionnaire directing symptoms to site-specific pelvic floor reconstructive surgery.

  18. Classic papers on pelvic floor physiotherapy: the most frequently cited articles in three decades (1983-2013).

    PubMed

    Fornari, Alexandre; Carboni, Cristiane

    2018-02-13

    Pelvic floor physiotherapy has been utilized extensively over the past decades for the treatment of pelvic floor dysfunctions. The aim of this study was to identify and characterize the most frequently cited articles on pelvic floor physiotherapy published in the last 30 years. A PubMed search of all articles published between 1983 and 2013 was performed. Articles with more than 100 citations were identified as "classic," and were further analyzed based on author names, year of publication, journal of publication, subject, study design, country of research, and number of citations. In 2017, a new search for papers on pelvic floor physiotherapy was conducted using the same methods to compare them with the 2013 data. Of 1,285 articles published between 1983 and 2013, only 20 articles were cited more than 100 times. Among them, we found 12 randomized clinical trials (RCTs) and only 4 reviews. The most common topics among the classic articles were behavior therapy, pelvic floor muscle training (PFMT), biofeedback-assisted PFMT, and neuromuscular electrical stimulation. In 2017, we found 1,745 papers containing the term "pelvic floor physiotherapy," indicating an increase of around 35% in 4 years. Although there is a fast-growing number of publications, we still have few classic papers on pelvic floor physiotherapy, concentrated in a few research centers. However, the large number of RCTs shows that these papers have a high scientific level, confirming that they can be classified as classic papers.

  19. The cleaning method selected for new PEX pipe installation can affect short-term drinking water quality.

    PubMed

    Kelley, Keven M; Stenson, Alexandra C; Cooley, Racheal; Dey, Rajarashi; Whelton, Andrew J

    2015-12-01

    The influence of four different cleaning methods used for newly installed polyethylene (PEX) pipes on chemical and odor quality was determined. Bench-scale testing of two PEX (type b) pipe brands showed that the California Plumbing Code PEX installation method does not maximize total organic carbon (TOC) removal. TOC concentration and threshold odor number values significantly varied between two pipe brands. Different cleaning methods impacted carbon release, odor, as well the level of drinking water odorant ethyl tert-butyl ether. Both pipes caused odor values up to eight times greater than the US federal drinking water odor limit. Unique to this project was that organic chemicals released by PEX pipe were affected by pipe brand, fill/empty cycle frequency, and the pipe cleaning method selected by the installer.

  20. Method and apparatus for reducing cleaning blade wear

    DOEpatents

    Grannes, Steven G.; Rhoades, Charles A.; Hebbie, Terry L.

    1992-01-01

    An improved cleaning blade construction (10) for eliminating erosion troughs (6) in the upper surface (15) of a cleaning blade member (14) by introducing pressurized fluid through a pressure manifold chamber (16) formed in the upper surface (15) of the cleaning blade member (14). The pressurized fluid will prevent carryback material (7) from passing through a wear groove (6) formed in the cleaning blade member.

  1. Effectiveness of HVAC duct cleaning procedures in improving indoor air quality.

    PubMed

    Ahmad, I; Tansel, B; Mitrani, J D

    2001-12-01

    Indoor air quality has become one of the most serious environmental concerns as an average person spends about 22 hr indoors on a daily basis. The study reported in this article, was conducted to determine the effectiveness of three commercial HVAC (Heating Ventilation Air Conditioning) duct cleaning processes in reducing the level of airborne particulate matter and viable bioaerosols. The three HVAC sanitation processes were: (1) Contact method (use of conventional vacuum cleaning of interior duct surfaces); (2) Air sweep method (use of compressed air to dislodging dirt and debris); (3) Rotary brush method (insertion of a rotary brush into the ductwork to agitate and dislodge the debris). Effectiveness of these sanitation processes was evaluated in terms of airborne particulate and viable bioaerosol concentrations in residential homes. Eight identical homes were selected in the same neighborhood. Two homes were cleaned using each procedure and two were used as controls. It was found that both particle count readings and bioaerosol concentrations were higher when cleaning was being performed than before or after cleaning, which suggests that dirt, debris and other pollutants may become airborne as a result of disturbances caused by the cleaning processes. Particle count readings at 0.3 micron size were found to have increased due to cigarette smoking. Particle counts at 1.0 micron size were reduced due to HVAC duct cleaning. Post-level bioaerosol concentrations, taken two days after cleaning, were found to be lower than the pre-level concentrations suggesting that the cleaning procedures were effective to some extent. Homes cleaned with the Air Sweep procedure showed the highest degree of reduction in bioaerosol concentration among the three procedures investigated.

  2. Assessment of disinfection of hospital surfaces using different monitoring methods.

    PubMed

    Ferreira, Adriano Menis; de Andrade, Denise; Rigotti, Marcelo Alessandro; de Almeida, Margarete Teresa Gottardo; Guerra, Odanir Garcia; dos Santos Junior, Aires Garcia

    2015-01-01

    to assess the efficiency of cleaning/disinfection of surfaces of an Intensive Care Unit. descriptive-exploratory study with quantitative approach conducted over the course of four weeks. Visual inspection, bioluminescence adenosine triphosphate and microbiological indicators were used to indicate cleanliness/disinfection. Five surfaces (bed rails, bedside tables, infusion pumps, nurses' counter, and medical prescription table) were assessed before and after the use of rubbing alcohol at 70% (w/v), totaling 160 samples for each method. Non-parametric tests were used considering statistically significant differences at p<0.05. after the cleaning/disinfection process, 87.5, 79.4 and 87.5% of the surfaces were considered clean using the visual inspection, bioluminescence adenosine triphosphate and microbiological analyses, respectively. A statistically significant decrease was observed in the disapproval rates after the cleaning process considering the three assessment methods; the visual inspection was the least reliable. the cleaning/disinfection method was efficient in reducing microbial load and organic matter of surfaces, however, these findings require further study to clarify aspects related to the efficiency of friction, its frequency, and whether or not there is association with other inputs to achieve improved results of the cleaning/disinfection process.

  3. Efficacy and acceptance of professional dental cleaning among nursing home residents.

    PubMed

    Barbe, Anna Greta; Kottmann, Hannah Elisa; Hamacher, Stefanie; Derman, Sonja Henny Maria; Noack, Michael Johannes

    2018-05-13

    To determine the impact of general and oral health status of nursing home residents in Germany on efficacy and acceptance of professional dental cleaning performed by a dental nurse. Participants (N = 41; mean age 83 ± 8 years) living in a nursing home were included. Personal and general health, oral health, oral hygiene habits, and needs were investigated. Individual acceptance regarding professional dental cleaning via different devices (scaler, interdental brushes, ultrasonic cleaning) was assessed, as was the efficacy of this method using after-cleaning indices. Oral health among nursing home residents was impaired and independent from dementia status. Most residents (33/41) performed oral hygiene procedures independently and showed better index values than those in need of external help. Residents requiring help with oral hygiene showed increased risk profiles (higher age, more often immobile, demented, more xerostomia). The dental cleaning procedure required a mean time of 37 ± 11 min, was widely accepted (36/41), and achieved clean results (plaque index 0.1 ± 0.5, oral hygiene index 0.2 ± 1.6, Volpe-Manhold index 0.4 ± 1.6); food residues were reduced to 0 independent from cognitive status. Regarding the cleaning methods, scalers were accepted best without difference between demented and non-demented residents. Professional dental cleaning in nursing homes is an accepted and efficacious oral hygiene procedure among nursing home residents. Professional dental cleaning is an efficacious and accepted method as a first step in line with strategies to improve oral health and should be considered in nursing home residents.

  4. Cleaning verification: A five parameter study of a Total Organic Carbon method development and validation for the cleaning assessment of residual detergents in manufacturing equipment.

    PubMed

    Li, Xue; Ahmad, Imad A Haidar; Tam, James; Wang, Yan; Dao, Gina; Blasko, Andrei

    2018-02-05

    A Total Organic Carbon (TOC) based analytical method to quantitate trace residues of clean-in-place (CIP) detergents CIP100 ® and CIP200 ® on the surfaces of pharmaceutical manufacturing equipment was developed and validated. Five factors affecting the development and validation of the method were identified: diluent composition, diluent volume, extraction method, location for TOC sample preparation, and oxidant flow rate. Key experimental parameters were optimized to minimize contamination and to improve the sensitivity, recovery, and reliability of the method. The optimized concentration of the phosphoric acid in the swabbing solution was 0.05M, and the optimal volume of the sample solution was 30mL. The swab extraction method was 1min sonication. The use of a clean room, as compared to an isolated lab environment, was not required for method validation. The method was demonstrated to be linear with a correlation coefficient (R) of 0.9999. The average recoveries from stainless steel surfaces at multiple spike levels were >90%. The repeatability and intermediate precision results were ≤5% across the 2.2-6.6ppm range (50-150% of the target maximum carry over, MACO, limit). The method was also shown to be sensitive with a detection limit (DL) of 38ppb and a quantitation limit (QL) of 114ppb. The method validation demonstrated that the developed method is suitable for its intended use. The methodology developed in this study is generally applicable to the cleaning verification of any organic detergents used for the cleaning of pharmaceutical manufacturing equipment made of electropolished stainless steel material. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Analysis of Latest Experience in Design of Industrial Buildings Reconstruction by Constructing Additional Interfloor Overlaps

    NASA Astrophysics Data System (ADS)

    Peshnina, I.; Sinitsina, O.

    2017-11-01

    The study relevance is determined by the increasing interest in reconstruction of city historical centers and located in the area of industrial buildings the functional profile of which needs to be changed. The problem of obtaining extra usable spaces in the historical centers of cities is solved by raising the number of storeys in the buildings which can be achieved by the construction of additional built-in inter-floor overlaps. The article is dedicated to the analysis of the recent years’ experience in reconstruction design involving this method in our country and abroad, in the Netherlands, in particular. The article presents the results of the analysis of the experience in reconstruction of the objects by constructing additional inter-floor overlaps and aims to define the optimum construction solution for built-in inter-floor overlapping and to develop non-existing solutions for wide application of this method in the reconstruction of a building with non-unified and unmodulated parameters. It was determined as expedient to apply a monolith reinforced concrete slab with the use of steel profiled flooring as a formwork and reinforcement and steel beams designed as “Built-in Beams” for the construction of built-in inter-floor overlaps in reconstruction. The article will be useful for specialists doing research in the sphere of reconstruction of the buildings and for the practical activity of design engineers.

  6. Female Pelvic Floor Biomechanics: Bridging the Gap

    PubMed Central

    Easley, Deanna C.; Abramowitch, Steven D.; Moalli, Pamela A.

    2017-01-01

    Purpose of review The pelvic floor is a complex assembly of connective tissues and striated muscle that simultaneously counteract gravitational forces, inertial forces, and intraabdominal pressures while maintaining the position of the pelvic organs. In 30% of women, injury or failure of the pelvic floor results in pelvic organ prolapse (POP). Surgical treatments have high recurrence rates, due, in part, to a limited understanding of physiologic loading conditions. It is critical to apply biomechanics to help elucidate how altered loading conditions of the pelvis contribute to the development of pelvic organ prolapse and to define surgeries to restore normal support. Recent findings Evidence suggests the ewe is a potential animal model for studying vaginal properties and that uterosacral and cardinal ligaments experience significant creep, which may be affecting surgical outcomes. A new method of measuring ligament displacements in vivo was developed, and finite element models that simulate urethral support, pelvic floor dynamics, and the impact of episiotomies on the pelvic floor were studied. Summary This review highlights some contributions over the past year, including mechanical testing and the creation of models, which are used to understand pelvic floor changes with loading, and the impact of surgical procedures, to illustrate how biomechanics is being utilized. PMID:28267057

  7. Need to Identify Parameters of Concrete in the Weakest Zone of the Industrial Floor

    NASA Astrophysics Data System (ADS)

    Stawiski, Bohdan; Radzik, Łukasz

    2017-10-01

    The ways in which industrial floors are exploited leads to the requirement for the highest strength of their upper zone. Physical phenomena occurring during the compaction and hardening of the concrete cause different strength distributions. In the top zone of industrial floors, the strength is significantly lower (over a dozen MPa) than the strength in the bottom zone (several dozen MPa). Standard tests of control samples do not detect this fact. Processes for the application and finishing of embedded mineral-aggregate hardeners (dry shakes) can be regarded as uncontrolled. The effects of the use of dry shakes are not evaluated. In combination with the phenomenon of bleeding, they often fail by delamination. This paper presents the results of industrial floor testing. The ultrasonic pulse velocity method with dry point contact transducers was used. The results show how upper layer strength was reduced, and how dry shakes application affected the strength of the floor. The strength distribution in hardened concrete, which delaminated from the rest of the floor was presented as well. The extension of compulsory control tests of concrete samples was proposed. In the authors’ opinion, particular attention should be paid to 3 centimetres of the upper layer.

  8. Cleaning Process Development for Metallic Additively Manufactured Parts

    NASA Technical Reports Server (NTRS)

    Tramel, Terri L.; Welker, Roger; Lowery, Niki; Mitchell, Mark

    2014-01-01

    Additive Manufacturing of metallic components for aerospace applications offers many advantages over traditional manufacturing techniques. As a new technology, many aspects of its widespread utilization remain open to investigation. Among these are the cleaning processes that can be used for post finishing of parts and measurements to verify effectiveness of the cleaning processes. Many cleaning and drying processes and measurement methods that have been used for parts manufactured using conventional techniques are candidates that may be considered for cleaning and verification of additively manufactured parts. Among these are vapor degreasing, ultrasonic immersion and spray cleaning, followed by hot air drying, vacuum baking and solvent displacement drying. Differences in porosity, density, and surface finish of additively manufactured versus conventionally manufactured parts may introduce new considerations in the selection of cleaning and drying processes or the method used to verify their effectiveness. This presentation will review the relative strengths and weaknesses of different candidate cleaning and drying processes as they may apply to additively manufactured metal parts for aerospace applications. An ultrasonic cleaning technique for exploring the cleanability of parts will be presented along with an example using additively manufactured Inconel 718 test specimens to illustrate its use. The data analysis shows that this ultrasonic cleaning approach results in a well-behaved ultrasonic cleaning/extraction behavior. That is, it does not show signs of accelerated cavitation erosion of the base material, which was later confirmed by neutron imaging. In addition, the analysis indicated that complete cleaning would be achieved by ultrasonic immersion cleaning at approximately 5 minutes, which was verified by subsequent cleaning of additional parts.

  9. Preliminary Results of Cleaning Process for Lubricant Contamination

    NASA Astrophysics Data System (ADS)

    Eisenmann, D.; Brasche, L.; Lopez, R.

    2006-03-01

    Fluorescent penetrant inspection (FPI) is widely used for aviation and other components for surface-breaking crack detection. As with all inspection methods, adherence to the process parameters is critical to the successful detection of defects. Prior to FPI, components are cleaned using a variety of cleaning methods which are selected based on the alloy and the soil types which must be removed. It is also important that the cleaning process not adversely affect the FPI process. There are a variety of lubricants and surface coatings used in the aviation industry which must be removed prior to FPI. To assess the effectiveness of typical cleaning processes on removal of these contaminants, a study was initiated at an airline overhaul facility. Initial results of the cleaning study for lubricant contamination in nickel, titanium and aluminum alloys will be presented.

  10. A CLEAN-based method for mosaic deconvolution

    NASA Astrophysics Data System (ADS)

    Gueth, F.; Guilloteau, S.; Viallefond, F.

    1995-03-01

    Mosaicing may be used in aperture synthesis to map large fields of view. So far, only MEM techniques have been used to deconvolve mosaic images (Cornwell (1988)). A CLEAN-based method has been developed, in which the components are located in a modified expression. This allows a better utilization of the information and consequent noise reduction in the overlapping regions. Simulations show that this method gives correct clean maps and recovers most of the flux of the sources. The introduction of the short-spacing visibilities in the data set is strongly required. Their absence actually introduces artificial lack of structures on the corresponding scale in the mosaic images. The formation of ``stripes'' in clean maps may also occur, but this phenomenon can be significantly reduced by using the Steer-Dewdney-Ito algorithm (Steer, Dewdney & Ito (1984)) to identify the CLEAN components. Typical IRAM interferometer pointing errors do not have a significant effect on the reconstructed images.

  11. Assessment of in-place wood floor systems

    Treesearch

    Michael O. Hunt; Robert J. Ross; Xiping Wang; Lawrence Andrew Soltis; R. R. Leavitt; Zhiyong Cai

    2007-01-01

    Structural assessment of in-place wood floors is currently limited to inspection of individual members. This is costly and laborious. Consequently, the continued use or adaptive reuse of old/historic buildings is often in jeopardy because of the lack of an efficient and economical assessment method. A systems approach of assessment is the subject of this research....

  12. 78 FR 21854 - Airworthiness Directives; The Boeing Company Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-12

    ...) inspections for cracks in the splice fitting, support frame, forward and aft inner chords, floor support... frame, floor support, forward and aft inner chords, and the bulkhead upper and lower webs of the body... in 14 CFR 11.43 and 11.45, by any of the following methods: Federal eRulemaking Portal: Go to http...

  13. Modeling Outcomes with Floor or Ceiling Effects: An Introduction to the Tobit Model

    ERIC Educational Resources Information Center

    McBee, Matthew

    2010-01-01

    In gifted education research, it is common for outcome variables to exhibit strong floor or ceiling effects due to insufficient range of measurement of many instruments when used with gifted populations. Common statistical methods (e.g., analysis of variance, linear regression) produce biased estimates when such effects are present. In practice,…

  14. Laser versus scalpel cleaning of crustose lichens on granite

    NASA Astrophysics Data System (ADS)

    Rivas, T.; Pozo-Antonio, J. S.; López de Silanes, M. E.; Ramil, A.; López, A. J.

    2018-05-01

    This paper addresses the evaluation of the cleaning of crustose lichens developing on granite. The evaluation was performed considering the effectiveness of the cleanings and harmfulness exerted on the granite. The laser cleaning of lichen was compared with the most conventional procedure, scalpel. The combination of both procedures was also tested. The study, which was carried out with two different species of crustose lichen, was also focused on the influence of the intrinsic characteristics of the lichen on the effectiveness. The cleanings were evaluated by optic and electronic microscopies, FTIR and colour spectrophotometry. A previous characterization of the lichen and its interaction with the granite using those analytical techniques were also performed. The laser cleaning effectiveness depends on the coverage and the colour of the lichen; also, the prior mechanical weakening of the lichen by scalpel seemed to improve the laser cleaning. The darkest lichen was satisfactorily removed by laser and with the combined cleaning. Conversely, the lightest lichen was more difficult to extract with laser than the darkest lichen, being necessary to apply both methods sequentially. Despite laser and the combination of methods cleaned satisfactorily the surface, they were unable to eliminate the thalli into fissures.

  15. Use of Synthetic Single-Stranded Oligonucleotides as Artificial Test Soiling for Validation of Surgical Instrument Cleaning Processes

    PubMed Central

    Wilhelm, Nadja; Perle, Nadja; Simmoteit, Robert; Schlensak, Christian; Wendel, Hans P.; Avci-Adali, Meltem

    2014-01-01

    Surgical instruments are often strongly contaminated with patients' blood and tissues, possibly containing pathogens. The reuse of contaminated instruments without adequate cleaning and sterilization can cause postoperative inflammation and the transmission of infectious diseases from one patient to another. Thus, based on the stringent sterility requirements, the development of highly efficient, validated cleaning processes is necessary. Here, we use for the first time synthetic single-stranded DNA (ssDNA_ODN), which does not appear in nature, as a test soiling to evaluate the cleaning efficiency of routine washing processes. Stainless steel test objects were coated with a certain amount of ssDNA_ODN. After cleaning, the amount of residual ssDNA_ODN on the test objects was determined using quantitative real-time PCR. The established method is highly specific and sensitive, with a detection limit of 20 fg, and enables the determination of the cleaning efficiency of medical cleaning processes under different conditions to obtain optimal settings for the effective cleaning and sterilization of instruments. The use of this highly sensitive method for the validation of cleaning processes can prevent, to a significant extent, the insufficient cleaning of surgical instruments and thus the transmission of pathogens to patients. PMID:24672793

  16. EVALUATION OF THREE CLEANING METHODS FOR REMOVING ASBESTOS FROM CARPET. DETERMINATION OF AIRBORNE ASBESTOS CONCENTRATIONS ASSOCIATED WITH EACH METHOD

    EPA Science Inventory

    This study was conducted to compare the effectiveness of three cleaning methods to remove asbestos from contaminated carpet and to determine the airborne asbestos concentrations associated with the use of each method. The carpet on which the methods were tested was naturally cont...

  17. Asbestos-fiber reentrainment during dry vacuuming and wet cleaning of asbestos-contaminated carpet. Report for January 1988-July 1989

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kominsky, J.R.; Freyberg, R.W.

    A study was conducted to evaluate the potential for asbestos fiber reentrainment during cleaning of carpet contaminated with asbestos. Two types of carpet cleaning equipment were evaluated at two carpet contamination levels. Airborne asbestos concentrations were determined before and during carpet cleaning. Overall, airborne asbestos concentrations were two to four times greater during the carpet cleaning activity. The level of asbestos contamination and the type of cleaning method used had no statistically significant effect on the relative increase of airborne asbestos concentrations during carpet cleaning.

  18. Physicochemical cleaning and recovery of coal

    NASA Astrophysics Data System (ADS)

    Wheelock, T. D.

    1982-03-01

    The development and demonstration of a method of depressing iron pyrites which is applicable to both the froth flotation and oil agglomeration methods of cleaning and recoverying fine-size coal are described.

  19. System and method for treatment of a flue gas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spiry, Irina Pavlovna; Wood, Benjamin Rue; Singh, Surinder Prabhjot

    A method for treatment of a flue gas involves feeding the flue gas and a lean solvent to an absorber. The method further involves reacting the flue gas with the lean solvent within the absorber to generate a clean flue gas and a rich solvent. The method also involves feeding the clean flue gas from the absorber and water from a source, to a wash tower to separate a stripped portion of the lean solvent from the clean flue gas to generate a washed clean flue gas and a mixture of the water and the stripped portion of the leanmore » solvent. The method further involves treating at least a portion of the mixture of the water and the stripped portion of the lean solvent via a separation system to separate the water from the stripped portion of the lean solvent.« less

  20. Association between the accessibility to lethal methods and method-specific suicide rates: An ecological study in Taiwan.

    PubMed

    Lin, Jin-Jia; Lu, Tsung-Hsueh

    2006-07-01

    To examine the association between availability of lethal methods of suicide and method-specific suicide rates at the city/ county level in Taiwan. Age-adjusted and age-specific suicide rates of 23 cities/counties in Taiwan for the years 1999 to 2003 were calculated. Partial correlation coefficients were used to examine cross-sectional associations between independent variables, i.e., proportion of agricultural population and proportion of households living on the sixth floor or above, and suicide rates by different methods (poisoning by solids/liquids, jumping, and hanging) after adjusting for unemployment rates and prevalence of depression. The partial correlation coefficient was 0.77 (p < .001) for proportion of agricultural population with solids/liquids poisoning suicide rates. It was 0.73 (p < .001) for the proportion of households living on the sixth floor or above with suicide rates by jumping. Correlations between hanging suicide rates and proportion of agricultural population or between hanging suicide rates and proportion of households living on the sixth floor or above were not significant. The results showed strong positive associations between access to lethal methods and method-specific suicide rates. Controlling the availability of pesticides and fencing high buildings or installing window guards may be effective measures for suicide prevention.

  1. Clean Water Act Analytical Methods

    EPA Pesticide Factsheets

    EPA publishes laboratory analytical methods (test procedures) that are used by industries and municipalities to analyze the chemical, physical and biological components of wastewater and other environmental samples required by the Clean Water Act.

  2. Alternative Chemical Cleaning Methods for High Level Waste Tanks: Actual Waste Testing with SRS Tank 5F Sludge

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    King, William D.; Hay, Michael S.

    Solubility testing with actual High Level Waste tank sludge has been conducted in order to evaluate several alternative chemical cleaning technologies for the dissolution of sludge residuals remaining in the tanks after the exhaustion of mechanical cleaning and sludge sluicing efforts. Tests were conducted with archived Savannah River Site (SRS) radioactive sludge solids that had been retrieved from Tank 5F in order to determine the effectiveness of an optimized, dilute oxalic/nitric acid cleaning reagent toward dissolving the bulk non-radioactive waste components. Solubility tests were performed by direct sludge contact with the oxalic/nitric acid reagent and with sludge that had beenmore » pretreated and acidified with dilute nitric acid. For comparison purposes, separate samples were also contacted with pure, concentrated oxalic acid following current baseline tank chemical cleaning methods. One goal of testing with the optimized reagent was to compare the total amounts of oxalic acid and water required for sludge dissolution using the baseline and optimized cleaning methods. A second objective was to compare the two methods with regard to the dissolution of actinide species known to be drivers for SRS tank closure Performance Assessments (PA). Additionally, solubility tests were conducted with Tank 5 sludge using acidic and caustic permanganate-based methods focused on the “targeted” dissolution of actinide species.« less

  3. Simulated-use validation of a sponge ATP method for determining the adequacy of manual cleaning of endoscope channels.

    PubMed

    Alfa, Michelle J; Olson, Nancy

    2016-05-04

    The objective of this study was to validate the relative light unit (RLU) cut-off of adequate cleaning of flexible colonoscopes for an ATP (adenosine tri-phosphate) test kit that used a sponge channel collection method. This was a simulated-use study. The instrument channel segment of a flexible colonoscope was soiled with ATS (artificial test soil) containing approximately 8 Log10 Enterococcus faecalis and Pseudomonas aeruginosa/mL. Full cleaning, partial cleaning and no cleaning were evaluated for ATP, protein and bacterial residuals. Channel samples were collected using a sponge device to assess residual RLUs. Parallel colonoscopes inoculated and cleaned in the same manner were sampled using the flush method to quantitatively assess protein and bacterial residuals. The protein and viable count benchmarks for adequate cleaning were <6.4 ug/cm(2) and <4 Log10 cfu/cm(2). The negative controls for the instrument channel, over the course of the study remained low with on average 14 RLUs, 0.04 ug/cm(2) protein and 0.025 Log10 cfu/cm(2). Partial cleaning resulted in an average of 6601 RLUs, 3.99 ug/cm(2), 5.25 Log10 cfu/cm(2) E. faecalis and 4.48 Log10 cfu/cm(2) P. aeruginosa. After full cleaning, the average RLU was 29 (range 7-71 RLUs) and the average protein, E. faecalis and P. aeruginosa residuals were 0.23 ug/cm(2), 0.79 and 1.61 Log10 cfu/cm(2), respectively. The validated cut-off for acceptable manual cleaning was set at ≤100 RLUs for the sponge collected channel ATP test kit.

  4. [Correlation of bacteria in the contaminated drug and the environmental microbes in the clean room for pharmaceutical microbial test investigated by FTIR].

    PubMed

    Pei, Lin; Hu, Chang-qin; Ma, Shi-hong; Dai, Hui; Hang, Tai-jun

    2007-11-01

    The FTIR method was used to investigate the correlation of bacteria in the contaminated drug and the environmental microbes in the clean room for pharmaceutical microbial test. The similarity of bacteria in the contaminated drug and environmental microbes was compared by critical hit value method and cluster analysis method. This constructed the FTIR spectra library of clean room environmental microbe, and determined the criterion to promptly judge if the bacteria isolated from pharmaceuticals were contaminated by environment or not, hence the exactness of "one-off report" of sterile test result can be guaranteed, and can be used for the dynamic monitoring of environmental bacteria of clean room. The method is proven to be simple, accurate and rapid, and can be easily spread to the pharmaceutical microbial control.

  5. Use of history science methods in exposure assessment for occupational health studies

    PubMed Central

    Johansen, K; Tinnerberg, H; Lynge, E

    2005-01-01

    Aims: To show the power of history science methods for exposure assessment in occupational health studies, using the dry cleaning industry in Denmark around 1970 as the example. Methods: Exposure data and other information on exposure status were searched for in unconventional data sources such as the Danish National Archives, the Danish Royal Library, archives of Statistics Denmark, the National Institute of Occupational Health, Denmark, and the Danish Labor Inspection Agency. Individual census forms were retrieved from the Danish National Archives. Results: It was estimated that in total 3267 persons worked in the dry cleaning industry in Denmark in 1970. They typically worked in small shops with an average size of 3.5 persons. Of these, 2645 persons were considered exposed to solvents as they were dry cleaners or worked very close to the dry cleaning process, while 622 persons were office workers, drivers, etc in shops with 10 or more persons. It was estimated that tetrachloroethylene constituted 85% of the dry cleaning solvent used, and that a shop would normally have two machines using 4.6 tons of tetrachloroethylene annually. Conclusion: The history science methods, including retrieval of material from the Danish National Archives and a thorough search in the Royal Library for publications on dry cleaning, turned out to be a very fruitful approach for collection of exposure data on dry cleaning work in Denmark. The history science methods proved to be a useful supplement to the exposure assessment methods normally applied in epidemiological studies. PMID:15961618

  6. Prevalence of lameness and associated risk factors in Canadian Holstein-Friesian cows housed in freestall barns.

    PubMed

    Solano, L; Barkema, H W; Pajor, E A; Mason, S; LeBlanc, S J; Zaffino Heyerhoff, J C; Nash, C G R; Haley, D B; Vasseur, E; Pellerin, D; Rushen, J; de Passillé, A M; Orsel, K

    2015-10-01

    Lameness is a severe welfare problem and a production-limiting disease in dairy farming. The objectives of this study were to determine prevalence of lameness and investigate cow- and herd-level factors associated with lameness in dairy cows housed in freestall barns in 3 Canadian provinces. A purposive sample of 40 Holstein-Friesian cows was selected from each of 141 dairy farms in Québec, Ontario, and Alberta. In total, 5,637 cows were scored once for lameness (presence of limping when walking). Data collected included information on individual cows (hock lesions, claw length, body condition score, parity, days in milk, and milk production), management practices (floor and stall cleaning routine, bedding routine, and footbath practices), and facility design (stall dimensions, stall base and bedding type, width of feed alley, flooring type, and slipperiness) hypothesized to be risk factors for lameness. Multilevel mixed logistic regression models were constructed (including farm as a random effect and province as a fixed effect). Herd-level lameness prevalence ranged from 0 to 69% (mean = 21%). Lameness prevalence increased with increasing parity; compared with first parity, cows in parity 2, 3, and ≥ 4 had 1.6, 3.3, and 4 times, respectively, higher odds of being lame. Furthermore, the odds of lameness were 1.6 times greater in cows with low body condition score (≤ 2.5) than in cows with a higher body condition score. In addition, injured hocks and overgrown claws were associated with 1.4- and 1.7-fold increased odds of being lame, respectively, whereas every 1 kg increase in daily milk production was associated with a 3% decrease in the odds of being lame. Lameness prevalence was higher in herds with ≤ 100 cows, but lower in barns with a sand or dirt stall base, or with bedding ≥ 2 cm deep. Cows exposed to very slippery floors had 2 times the odds of being lame compared with cows exposed to nonslippery floors. We attributed the wide range of lameness prevalence to the great variability in facilities and management practices among farms. Finally, we inferred that the prevalence of lameness could be decreased by improving management of multiparous, thin, or injured cows and by adopting management practices intended to improve cow comfort, namely the floor's slip resistance and the stall's lying surface. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  7. Fluorescent Penetrant INSPECTION—CLEANING Study Update

    NASA Astrophysics Data System (ADS)

    Eisenmann, D.; Brasche, L.

    2009-03-01

    Fluorescent penetrant inspection (FPI) is widely used in the aviation industry and other industries for surface-breaking crack detection. As with all inspection methods, adherence to the process parameters is critical to the successful detection of defects. There is variety of lubricants and surface coatings used in the aviation industry which must be removed prior to FPI. Before the FPI process begins, components are cleaned using a variety of cleaning methods which are selected based on the alloy and the soil types which must be removed. It is also important that the cleaning process not adversely affect the FPI process. From the first three phases of this project it has been found that a hot water rinse can aid in the detection process when using this nondestructive method.

  8. [Effect of manual cleaning and machine cleaning for dental handpiece].

    PubMed

    Zhou, Xiaoli; Huang, Hao; He, Xiaoyan; Chen, Hui; Zhou, Xiaoying

    2013-08-01

    Comparing the dental handpiece' s cleaning effect between manual cleaning and machine cleaning. Eighty same contaminated dental handpieces were randomly divided into experimental group and control group, each group contains 40 pieces. The experimental group was treated by full automatic washing machine, and the control group was cleaned manually. The cleaning method was conducted according to the operations process standard, then ATP bioluminescence was used to test the cleaning results. Average relative light units (RLU) by ATP bioluminescence detection were as follows: Experimental group was 9, control group was 41. The two groups were less than the recommended RLU value provided by the instrument manufacturer (RLU < or = 45). There was significant difference between the two groups (P < 0.05). The cleaning quality of the experimental group was better than that of control group. It is recommended that the central sterile supply department should clean dental handpieces by machine to ensure the cleaning effect and maintain the quality.

  9. Laser Ablation Cleaning of Self-Reacting Friction Stir Weld Seam Surfaces: A Preliminary Evaluation

    NASA Technical Reports Server (NTRS)

    Nunes, A. C., Jr.; Russell, C. K.; Brooke, S. A.; Parry, Q.; Lowrey, N. M.

    2014-01-01

    Anodized aluminum panels were cleaned by three lasers at three separate sites with a view to determining whether more economical laser cleaning might supplant current manual cleaning methods for preparation of surfaces to be welded by the self-reacting friction stir process. Uncleaned panels yielded welds exhibiting residual oxide defect (ROD) and failing at very low stresses along the trace of the weld seam. Manually cleaned panels yielded welds without ROD; these welds failed at nominal stress levels along an angled fracture surface not following the weld seam trace. Laser cleaned panels yielded welds failing at intermediate stress levels. The inadequacy of the laser cleaning processes leaves questions: Was the anodized aluminum test too stringent to represent actual cleaning requirements? Were the wrong laser cleaning techniques/parameters used for the study? Is the laser cleaning mechanism inadequate for effective preweld surface cleaning?

  10. Evaluation of two recommended disinfection methods for cleaning cloths used in food services of southern Brazil

    PubMed Central

    Bartz, Sabrina; Tondo, Eduardo Cesar

    2013-01-01

    In the State of Rio Grande do Sul (RS), Southern Brazil, a good manufacturing practices regulation was published recommending two disinfection methods for cleaning cloths used in food services. The aim of the present study was to evaluate the efficacy of those methods. Cleaning cloths were sampled without prior notice at food services, on common working days. For the analyses, the cloths were divided in two sub-samples, being one of them microbiologically analyzed. The second sub-sample was further divided in two pieces and submitted to hand washing for two minutes. After that, one piece was boiled in water for 15 min and the other one was soaked in a 200 ppm sodium hypochlorite solution for 15 min. Both pieces of cloth were submitted to microbiological analyses. Cleaning cloths presented total aerobic mean counts of 6.9 ± 6.7 log/cm2. All cleaning cloths presented coliform contamination, and 40% demonstrated mean counts of 6.2 ± 5.6 log/cm2. Presumptive S. aureus mean counts of 5.5 ± 4.9 log/cm2 were found. No statistic correlation was observed among the number of meals served daily in the food services and the microbiological contamination levels. After washing and disinfection, microbiological counts were significantly (p < 0.05) reduced by both methods, achieving an approximately 5 log reduction. The reductions achieved by the sodium hypochlorite soaking method and the boiling method were not significantly different. Thus, it was possible to conclude that both recommended methods were suitable to disinfect cleaning cloths used in food services. PMID:24516443

  11. Quantitative determination and sampling of azathioprine residues for cleaning validation in production area.

    PubMed

    Fazio, Tatiana Tatit; Singh, Anil Kumar; Kedor-Hackmann, Erika Rosa Maria; Santoro, Maria Inês Rocha Miritello

    2007-03-12

    Cleaning validation is an integral part of current good manufacturing practices in any pharmaceutical industry. Nowadays, azathioprine and several other pharmacologically potent pharmaceuticals are manufactured in same production area. Carefully designed cleaning validation and its evaluation can ensure that residues of azathioprine will not carry over and cross contaminate the subsequent product. The aim of this study was to validate simple analytical method for verification of residual azathioprine in equipments used in the production area and to confirm efficiency of cleaning procedure. The HPLC method was validated on a LC system using Nova-Pak C18 (3.9 mm x 150 mm, 4 microm) and methanol-water-acetic acid (20:80:1, v/v/v) as mobile phase at a flow rate of 1.0 mL min(-1). UV detection was made at 280 nm. The calibration curve was linear over a concentration range from 2.0 to 22.0 microg mL(-1) with a correlation coefficient of 0.9998. The detection limit (DL) and quantitation limit (QL) were 0.09 and 0.29 microg mL(-1), respectively. The intra-day and inter-day precision expressed as relative standard deviation (R.S.D.) were below 2.0%. The mean recovery of method was 99.19%. The mean extraction-recovery from manufacturing equipments was 83.5%. The developed UV spectrophotometric method could only be used as limit method to qualify or reject cleaning procedure in production area. Nevertheless, the simplicity of spectrophotometric method makes it useful for routine analysis of azathioprine residues on cleaned surface and as an alternative to proposed HPLC method.

  12. Evaluation of two recommended disinfection methods for cleaning cloths used in food services of southern Brazil.

    PubMed

    Bartz, Sabrina; Tondo, Eduardo Cesar

    2013-01-01

    In the State of Rio Grande do Sul (RS), Southern Brazil, a good manufacturing practices regulation was published recommending two disinfection methods for cleaning cloths used in food services. The aim of the present study was to evaluate the efficacy of those methods. Cleaning cloths were sampled without prior notice at food services, on common working days. For the analyses, the cloths were divided in two sub-samples, being one of them microbiologically analyzed. The second sub-sample was further divided in two pieces and submitted to hand washing for two minutes. After that, one piece was boiled in water for 15 min and the other one was soaked in a 200 ppm sodium hypochlorite solution for 15 min. Both pieces of cloth were submitted to microbiological analyses. Cleaning cloths presented total aerobic mean counts of 6.9 ± 6.7 log/cm(2). All cleaning cloths presented coliform contamination, and 40% demonstrated mean counts of 6.2 ± 5.6 log/cm(2). Presumptive S. aureus mean counts of 5.5 ± 4.9 log/cm(2) were found. No statistic correlation was observed among the number of meals served daily in the food services and the microbiological contamination levels. After washing and disinfection, microbiological counts were significantly (p < 0.05) reduced by both methods, achieving an approximately 5 log reduction. The reductions achieved by the sodium hypochlorite soaking method and the boiling method were not significantly different. Thus, it was possible to conclude that both recommended methods were suitable to disinfect cleaning cloths used in food services.

  13. Preferred and Minimum Acceptable Listening Levels for Musicians while Using Floor and In-Ear Monitors

    ERIC Educational Resources Information Center

    Federman, Jeremy; Ricketts, Todd

    2008-01-01

    Purpose: This study examined the impact that changing on-stage music and crowd noise levels during musical performance had on preferred listening levels (PLLs) and minimum acceptable listening levels (MALLs) across both floor and in-ear monitors. Method: Participants for this study were 23- to 48-year-old musicians, with and without hearing loss,…

  14. CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF FLOOR DUST SAMPLES FOR PERSISTENT ORGANIC POLLUTANTS (SOP-2.19)

    EPA Science Inventory

    This SOP describes the method for collecting a floor dust sample from carpet. Dust samples will be collected in the room that the child uses most at home and/or at day care using a High Volume Small Surface Sampler (HVS3). In addition, participants will also be asked to donate a ...

  15. ATP Bioluminometers Analysis on the Surfaces of Removable Orthodontic Aligners after the Use of Different Cleaning Methods

    PubMed Central

    Levrini, Luca; Mangano, Alessandro; Margherini, Silvia; Tenconi, Camilla; Vigetti, Davide; Muollo, Raffaele; Marco Abbate, Gian

    2016-01-01

    Purpose. The aim was to quantify the bacteria concentration on the surface of orthodontic clear aligners using three different cleaning methods. Furthermore the objective was to validate the efficacy of the bioluminometer in assessing the bacteria concentration. Materials and Methods. Twenty subjects (six males and fourteen females) undergoing orthodontic therapy with clear aligners (Invisalign® Align Technology, Santa Clara, California) were enrolled in this study. The observation time was of six weeks. The patients were instructed to use different cleaning methods (water, brushing with toothpaste, and brushing with toothpaste and use of sodium carbonate and sulphate tablet). At the end of each phase a microbiological analysis was performed using the bioluminometer. Results. The highest bacteria concentration was found on aligners cleaned using only water (583 relative light units); a value of 189 relative light units was found on aligners cleaned with brushing and toothpaste. The lowest bacteria concentration was recorded on aligners cleaned with brushing and toothpaste and the use of sodium carbonate and sulfate tablet. Conclusions. The mechanical removal of the bacterial biofilm proved to be effective with brushing and toothpaste. The best results in terms of bacteria concentration were achieved adding the use of sodium carbonate and sulfate tablet. PMID:27242901

  16. Experimental Investigation of SBLI to Unravel Inlet Unstart Physics

    NASA Astrophysics Data System (ADS)

    Funderburk, Morgan; Narayanaswamy, Venkateswaran

    2016-11-01

    The phenomenon of shock boundary layer interaction (SBLI) driven inlet unstart persists as one of the most significant problems facing supersonic ramjet/scramjet engines. In order to determine how the characteristics of the SBLI units specific to rectangular inlets evolve during an unstart event, an experimental investigation is made using surface streakline methods and pitot/wall pressure measurements in the vicinity of the floor and corner SBLI induced by a compression ramp in a rectangular channel. Mean and unsteady measurements were taken at a variety of shock strengths to simulate the evolution of the combustion-induced back pressure ratio during unstart. The freestream Mach number was also varied. Statistical correlation methods were used to determine the degree of interaction between the floor and corner SBLI with different flowfield locations for the various test conditions. Finally, comparison to a two-dimensional compression ramp SBLI was made to determine any modification caused by the introduction of the corner SBLI. Results indicate that the floor and corner SBLI transition from distinct units to members of a global separated flow with increasing back pressure, and that considerable modification of the floor SBLI by the corner flow occurs. AFOSR Grant FA9550-15-1-0296.

  17. The impact of pelvic floor muscle training on the quality of life of women with urinary incontinence: a systematic literature review

    PubMed Central

    Radzimińska, Agnieszka; Strączyńska, Agnieszka; Weber-Rajek, Magdalena; Styczyńska, Hanna; Strojek, Katarzyna; Piekorz, Zuzanna

    2018-01-01

    Purpose The purpose of this review was to assess the effectiveness of pelvic floor muscle training (PFMT) in the treatment of urinary incontinence (UI) in women, with a particular focus on the impact of this form of therapy on the patients’ quality of life (QoL). Methods The following electronic databases were searched: PubMed, Embase, and Cochrane Library (articles only in English, 1990–2017). Search terms were as follows: urinary incontinence, pelvic floor muscle training, pelvic floor exercises, quality of life. Systematic review methods were based on the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) statement. Results The assessment of the impact of PFMT on the QoL of women with UI was conducted among 2,394 women in 24 selected studies. After the end of treatment, the majority of patients in the experimental groups noted a statistically significant improvement in QoL. Conclusion The results of this literature review demonstrate that PFMT is an effective treatment for UI in women. PFMT significantly improves the QoL of women with UI, which is an important determinant of their physical, mental, and social functioning.

  18. Stress distribution characteristics in the vicinity of coal seam floor

    NASA Astrophysics Data System (ADS)

    Cui, Zimo; Chanda, Emmanuel; Zhao, Jingli; Wang, Zhihe

    2018-01-01

    Although longwall top-coal caving (LTCC) has been a popular, more productive and cost-effective method in recent years, roadway floor heave and rock bursts frequently appear when exploiting such coal seams with large dip angle. This paper proposes addressing this problem by adopting three-dimensional roadway layout of stagger arrangement (3-D RLSA). In this study, the first step was to analyse the stress distribution characteristics in the vicinity of coal seam floor based on the stress slip line field theory. In the second step, numerical calculation using FLAC3D was conducted. Finally, an evaluation of the 3-D RLSA for solving this particular issue was given. Results indicate that for this particular mine the proposed 3-D RLSA results in 24% increase in the coal recovery ratio and a modest reduction in excavation and maintenance costs compared to the conventional LTCC method.

  19. Surface cleaning for negative electron affinity GaN photocathode

    NASA Astrophysics Data System (ADS)

    Qiao, Jianliang; Yin, Yingpeng; Gao, Youtang; Niu, Jun; Qian, Yunsheng; Chang, Benkang

    2012-10-01

    In the preparation process for negative electron affinity (NEA) GaN photocathode, the surface cleanness is very important to activation, it influences the sensitivity and stability of NEA GaN photocathode. The traditional corrosion methods based on oxidizing and dissolving can't remove oxygen (O) and carbon (C) on GaN surface effectively. How to get an ideal atom clean surface is still an important question at present. The cleaning techniques for GaN photocathode was studied by using NEA photocathode activation system and XPS surface analysis system. The experiment sample is p-type GaN doped with Mg, doped concentration is 1.37×1017 cm-3, the transfer rate is 3.08 cm2/V-S, and the thickness of activation layer is 0.51 μm, the substrate is 300 μm thick sapphire. The sample was dealed with chemical cleaning depuration at first. And to get the atom clean surface, the vacuum heat cleaning process was needed. The methods of chemical cleaning and the vacuum heating cleaning were given in detail. According to the X-ray photoelectron spectroscopy of GaN surface after chemical cleaning and the vacuum degree curve of the activation chamber during the heat cleaning, the cleaning effect and the cleaning mechanism were discussed. After the effective chemical cleaning and the heating of 700 Centigrade degree about 20 minutes in ultrahigh vacuum system, the oxides and carbon contaminants on cathode surface can be removed effectively, and the ideal atom clean surface can be obtained. The purpose of heating depuration process is that not only to get the atom clean GaN surface, but also to guarantee the contents of Ga, N on GaN surface stabilize and to keep the system ultra-high vacuum degree. Because of the volatilization of oxide and carbon impurity on the cathode surface, the vacuum degree curve drops with the rising of temperature on the whole.

  20. Evaluation of the Acoustic Measurement Capability of the NASA Langley V/STOL Wind Tunnel Open Test Section with Acoustically Absorbent Ceiling and Floor Treatments

    NASA Technical Reports Server (NTRS)

    Theobald, M. A.

    1978-01-01

    The single source location used for helicopter model studies was utilized in a study to determine the distances and directions upstream of the model accurate at which measurements of the direct acoustic field could be obtained. The method used was to measure the decrease of sound pressure levels with distance from a noise source and thereby determine the Hall radius as a function of frequency and direction. Test arrangements and procedures are described. Graphs show the normalized sound pressure level versus distance curves for the glass fiber floor treatment and for the foam floor treatment.

  1. Genital Autocleaning in the Male Cricket Gryllus bimaculatus (1): Structure and Function of the Genital Membrane.

    PubMed

    Kumashiro, Mikihiko; Sakai, Masaki

    2016-12-01

    We found that the genitalia of the male cricket Gryllus bimaculatus are equipped with an autocleaning system. The cricket keeps its genitalia clean by removing foreign matter and endogenous waste. Morphological study showed that the membrane complex consists of a median pouch and a genital chamber floor covered by small scales, each of which has a base of approximately 10 µm in width and a fringe with 5-10 spines 3-20 µm in length. The scales are arranged symmetrically about the midline, curving gradually in the lateral direction and continuing to the lateral pouch serving as a trash container. Observation of cleaning revealed that a small piece of artificial dirt placed on the membrane complex was conveyed over a distance of 1.3 mm to the lateral pouch in 12 minutes. Inspection of the dorsal pouch just after spermatophore extrusion in the mating stage revealed that there were patchy remnants of spermatophore material on the inner surface of the pouch, but that these were evacuated in a few minutes. Surgical elimination of the median pouch caused the formation of abnormal spermatophores with the sperm tube and attachment plate being deformed. These results suggest that genital autocleaning is indispensable for the production of a normal spermatophore in the male cricket.

  2. Stratigraphic framework of inner shelf storm-dominated sand ridges, Alabama EEZ: Implications for sequence stratigraphy, global climate change, and petroleum exploration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davies, D.J.; Parker, S.J.

    The Alabama exclusive economic zone (EEZ) contains an abundance of orthoquartzitic shelf sand ridges elongate northwest-southeast diagonally from the shoreline. Soft-sediment peels from 59 Vibracores[sup TM] from the Alabama inner shelf permit detailed description of sand ridge sedimentary structures, fabrics, and eight sea-floor sediment types. These overlie the pre-Holocene sequence boundary and lower Holocene transgressive sediments. In general, the ridges are capped by coarse stacked graded shelly sands, echinoid sands, and clean sands deposited well above storm wave base. The graded shelly sand microfacies, the most common sediment type, is inferred to represent shelf storm deposits because of its gradedmore » nature, sharp base, and variable thickness (0.1 to 4 m). Considerable patchiness of facies is found on a single sand ridge. The facies patchiness may result from the interplay between relict sediment distribution, present hydrodynamics and local difference in preserved shell content. Due to the microtidal regime of the Alabama EEZ and the prevalence of the graded sands on the ridge crests, the ridges are interpreted to be dominantly storm-wave in origin. This type of coarse, clean sandy deposit is a poorly studied yet important possible model for many shelf-sand petroleum reservoirs.« less

  3. Laser etching of polymer masked leadframes

    NASA Astrophysics Data System (ADS)

    Ho, C. K.; Man, H. C.; Yue, T. M.; Yuen, C. W.

    1997-02-01

    A typical electroplating production line for the deposition of silver pattern on copper leadframes in the semiconductor industry involves twenty to twenty five steps of cleaning, pickling, plating, stripping etc. This complex production process occupies large floor space and has also a number of problems such as difficulty in the production of rubber masks and alignment, generation of toxic fumes, high cost of water consumption and sometimes uncertainty on the cleanliness of the surfaces to be plated. A novel laser patterning process is proposed in this paper which can replace many steps in the existing electroplating line. The proposed process involves the application of high speed laser etching techniques on leadframes which were protected with polymer coating. The desired pattern for silver electroplating is produced by laser ablation of the polymer coating. Excimer laser was found to be most effective for this process as it can expose a pattern of clean copper substrate which can be silver plated successfully. Previous working of Nd:YAG laser ablation showed that 1.06 μm radiation was not suitable for this etching process because a thin organic and transparent film remained on the laser etched region. The effect of excimer pulse frequency and energy density upon the removal rate of the polymer coating was studied.

  4. The effect of ozonization on furniture dust: microbial content and immunotoxicity in vitro.

    PubMed

    Huttunen, Kati; Kauhanen, Eeva; Meklin, Teija; Vepsäläinen, Asko; Hirvonen, Maija-Riitta; Hyvärinen, Anne; Nevalainen, Aino

    2010-05-01

    Moisture and mold problems in buildings contaminate also the furniture and other movable property. If cleaning of the contaminated furniture is neglected, it may continue to cause problems to the occupants even after the moisture-damage repairs. The aim of this study was to determine the effectiveness of high-efficiency ozone treatment in cleaning of the furniture from moisture-damaged buildings. In addition, the effectiveness of two cleaning methods was compared. Samples were vacuumed from the padded areas before and after the treatment. The microbial flora and concentrations in the dust sample were determined by quantitative cultivation and QPCR-methods. The immunotoxic potential of the dust samples was analyzed by measuring effects on cell viability and production of inflammatory mediators in vitro. Concentrations of viable microbes decreased significantly in most of the samples after cleaning. Cleaning with combined steam wash and ozonisation was more effective method than ozonising alone, but the difference was not statistically significant. Detection of fungal species with PCR showed a slight but nonsignificant decrease in concentrations after the cleaning. The immunotoxic potential of the collected dust decreased significantly in most of the samples. However, in a small subgroup of samples, increased concentrations of microbes and immunotoxicological activity were detected. This study shows that a transportable cleaning unit with high-efficiency ozonising is in most cases effective in decreasing the concentrations of viable microbes and immunotoxicological activity of the furniture dust. However, the method does not destroy or remove all fungal material present in the dust, as detected with QPCR analysis, and in some cases the cleaning procedure may increase the microbial concentrations and immunotoxicity of the dust. Copyright 2010 Elsevier B.V. All rights reserved.

  5. Removal of brownish-black tarnish on silver-copper alloy objects with sodium glycinate

    NASA Astrophysics Data System (ADS)

    de Figueiredo, João Cura D.'Ars; Asevedo, Samara Santos; Barbosa, João Henrique Ribeiro

    2014-10-01

    This article has the principal aim of presenting a new method of chemical cleaning of tarnished silver-copper alloy objects. The chemical cleaning must be harmless to the health, selective to tarnish removal, and easy to use. Sodium glycinate was selected for the study. The reactions of sodium glycinate with tarnish and the silver-copper alloy were evaluated. Products of the reaction, the lixiviated material, and the esthetics of silver-copper alloy coins (used as prototypes) were studied to evaluate if the proposed method can be applied to the cleaning of silver objects. Silver-copper alloys can be deteriorated through a uniform and superficial corrosion process that produces brownish-black tarnish. This tarnish alters the esthetic of the object. The cleaning of artistic and archeological objects requires more caution than regular cleaning, and it must take into account the procedures for the conservation and restoration of cultural heritage. There are different methods for cleaning silver-copper alloy objects, chemical cleaning is one of them. We studied two chemical cleaning methods that use sodium glycinate and sodium acetylglycinate solutions. Silver-copper alloy coins were artificially corroded in a basic thiourea solution and immersed in solutions of sodium glycinate and sodium acetylglycinate. After immersion, optical microscopy and scanning electron microscopy of the surfaces were studied. The sodium glycinate solution was shown to be very efficient in removing the brownish-black tarnish. Absorption spectroscopy measured the percentage of silver and copper lixiviated in immersion baths, and very small quantities of these metals were detected. Infrared absorption spectroscopy and X-ray fluorescence characterized the obtained products. The greater efficiency of the sodium glycinate solution compared to the sodium acetylglycinate solution was explained by chelation and Hard-Soft Acid-Base Theory with the aid of quantum chemical calculations.

  6. Emission of volatile organic compounds (VOCs) from PVC floor coverings.

    PubMed

    Wiglusz, R; Igielska, B; Sitko, E; Nikel, G; Jarnuszkiewicz, I

    1998-01-01

    In this study 29 PVC floor coverings were tested for emission of vinyl chloride (VC) and other volatile organic compounds (VOCs). A study on the effect of higher temperature on emission of VOCs from newly manufactured PVC flooring was also carried out. The study was conducted in climatic chamber, according to Polish Standard PN-89/Z-04021. GC method was used for analyzing of the compounds emitted. VC was not emitted from any of the floorings tested. Other VOCs were emitted in different concentrations. The influence of temperature on emission was conducted at temperatures of 23 degrees C and 35 degrees C from 2 hrs up to 180 days after introduction of materials in the chamber. The increase of temperature caused increase of total volatile organic compounds (TVOC) emission during 24 hrs of experiment. Then the emission was comparable for both temperatures. After 9 days emission of identified and unidentified compounds (TVOC) showed a rapid decay and stayed on very low level during a few months. The study conducted showed that PVC floorings after 10 days of installation in the room should not be source of indoor air contamination.

  7. Evaluation of HEPA vacuum cleaning and dry steam cleaning in reducing levels of polycyclic aromatic hydrocarbons and house dust mite allergens in carpets

    PubMed Central

    Yu, Chang Ho; Yiin, Lih-Ming; Fan, Zhi-Hua (Tina); Rhoads, George G.

    2014-01-01

    Dry steam cleaning, which has gained recent attention as an effective method to reduce house dust mite (HDM) allergen concentration and loading in carpets, was evaluated in this study for its efficacy in lowering levels of polycyclic aromatic hydrocarbons (PAHs) as well as HDM allergens. Fifty urban homes with wail-to-wall carpets, mostly low-income and with known lead contamination, were studied in 2003 and 2004. Two carpet-cleaning interventions were compared: Repeated HEPA (High Efficiency Particulate Air filtered) vacuuming alone and repeated HEPA vacuuming supplemented with dry steam cleaning. Vacuum samples were collected to measure carpet loading of dust and contaminants immediately before and after cleaning. Paired comparisons were conducted to evaluate the effectiveness of the cleaning protocols in reducing the levels of PAHs and HDM allergens in carpets. The results indicated that both cleaning methods substantially reduced the loading of PAHs and HDM allergens as well as dust in carpets (p < 0.0001). The reductions in loading of dust (64.4%), PAHs (69.1%), and HDM allergens (85.5%), by dry steam cleaning plus repetitive HEPA vacuuming were larger than the reductions by regular HEPA vacuuming alone: dust (55.5%), PAHs (58.6%), and HDM allergens (80.8%), although the difference was statistically significant only for dust and PAHs. We conclude that intensive HEPA vacuum cleaning substantially reduced the loading of PAHs and HDM allergens in carpets in these urban homes and that dry steam cleaning added modestly to cleaning effectiveness. PMID:19137159

  8. Improving Overall Equipment Effectiveness Using CPM and MOST: A Case Study of an Indonesian Pharmaceutical Company

    NASA Astrophysics Data System (ADS)

    Omega, Dousmaris; Andika, Aditya

    2017-12-01

    This paper discusses the results of a research conducted on the production process of an Indonesian pharmaceutical company. The company is experiencing low performance in the Overall Equipment Effectiveness (OEE) metric. The OEE of the company machines are below world class standard. The machine that has the lowest OEE is the filler machine. Through observation and analysis, it is found that the cleaning process of the filler machine consumes significant amount of time. The long duration of the cleaning process happens because there is no structured division of jobs between cleaning operators, differences in operators’ ability, and operators’ inability in utilizing available cleaning equipment. The company needs to improve the cleaning process. Therefore, Critical Path Method (CPM) analysis is conducted to find out what activities are critical in order to shorten and simplify the cleaning process in the division of tasks. Afterwards, The Maynard Operation and Sequence Technique (MOST) method is used to reduce ineffective movement and specify the cleaning process standard time. From CPM and MOST, it is obtained the shortest time of the cleaning process is 1 hour 28 minutes and the standard time is 1 hour 38.826 minutes.

  9. Supersonic gas-liquid cleaning system

    NASA Technical Reports Server (NTRS)

    Caimi, Raoul E. B.; Thaxton, Eric A.

    1994-01-01

    A system to perform cleaning and cleanliness verification is being developed to replace solvent flush methods using CFC 113 for fluid system components. The system is designed for two purposes: internal and external cleaning and verification. External cleaning is performed with the nozzle mounted at the end of a wand similar to a conventional pressure washer. Internal cleaning is performed with a variety of fixtures designed for specific applications. Internal cleaning includes tubes, pipes, flex hoses, and active fluid components such as valves and regulators. The system uses gas-liquid supersonic nozzles to generate high impingement velocities at the surface of the object to be cleaned. Compressed air or any inert gas may be used to provide the conveying medium for the liquid. The converging-diverging nozzles accelerate the gas-liquid mixture to supersonic velocities. The liquid being accelerated may be any solvent including water. This system may be used commercially to replace CFC and other solvent cleaning methods widely used to remove dust, dirt, flux, and lubricants. In addition, cleanliness verification can be performed without the solvents which are typically involved. This paper will present the technical details of the system, the results achieved during testing at KSC, and future applications for this system.

  10. Supersonic gas-liquid cleaning system

    NASA Astrophysics Data System (ADS)

    Caimi, Raoul E. B.; Thaxton, Eric A.

    1994-02-01

    A system to perform cleaning and cleanliness verification is being developed to replace solvent flush methods using CFC 113 for fluid system components. The system is designed for two purposes: internal and external cleaning and verification. External cleaning is performed with the nozzle mounted at the end of a wand similar to a conventional pressure washer. Internal cleaning is performed with a variety of fixtures designed for specific applications. Internal cleaning includes tubes, pipes, flex hoses, and active fluid components such as valves and regulators. The system uses gas-liquid supersonic nozzles to generate high impingement velocities at the surface of the object to be cleaned. Compressed air or any inert gas may be used to provide the conveying medium for the liquid. The converging-diverging nozzles accelerate the gas-liquid mixture to supersonic velocities. The liquid being accelerated may be any solvent including water. This system may be used commercially to replace CFC and other solvent cleaning methods widely used to remove dust, dirt, flux, and lubricants. In addition, cleanliness verification can be performed without the solvents which are typically involved. This paper will present the technical details of the system, the results achieved during testing at KSC, and future applications for this system.

  11. Packaging system with cleaning channel and method of making the same

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fang, Lu

    A packaging structure and method for surface mount integrated circuits reduces electrochemical migration (ECM) problems by including one or more cleaning channels to effectively and efficiently remove flux residue that may otherwise remain lodged in gaps between the surface mount package and the printed circuit board. A cleaning channel may be formed along a bottom surface of the surface mount package (i.e., the surface facing the printed circuit board), or along a portion of a top surface of the printed circuit board. In either case, the inclusion of a cleaning channel enlarges the gap between the bottom surface of themore » surface mount package and the printed circuit board and creates a path for contaminants to be flushed out during a cleaning process.« less

  12. Liquid oxygen dicting cleaned by falling film method

    NASA Technical Reports Server (NTRS)

    Paul, H. I.

    1967-01-01

    Principle of a vertical falling film is used to clean contaminated large diameter and length liquid oxygen /LOX/ cylindrical ducting. The cleaning cycle is performed by flowing trichloroethylene in a falling film down a vertically mounted duct for approximately one hour.

  13. Botulinum toxin type-A injection to treat patients with intractable anismus unresponsive to simple biofeedback training

    PubMed Central

    Zhang, Yong; Wang, Zhen-Ning; He, Lei; Gao, Ge; Zhai, Qing; Yin, Zhi-Tao; Zeng, Xian-Dong

    2014-01-01

    AIM: To evaluate the efficacy of botulinum toxin type A injection to the puborectalis and external sphincter muscle in the treatment of patients with anismus unresponsive to simple biofeedback training. METHODS: This retrospective study included 31 patients suffering from anismus who were unresponsive to simple biofeedback training. Diagnosis was made by anorectal manometry, balloon expulsion test, surface electromyography of the pelvic floor muscle, and defecography. Patients were given botulinum toxin type A (BTX-A) injection and pelvic floor biofeedback training. Follow-up was conducted before the paper was written. Improvement was evaluated using the chronic constipation scoring system. RESULTS: BTX-A injection combined with pelvic floor biofeedback training achieved success in 24 patients, with 23 maintaining persistent satisfaction during a mean period of 8.4 mo. CONCLUSION: BTX-A injection combined with pelvic floor biofeedback training seems to be successful for intractable anismus. PMID:25253964

  14. Analytical prediction of the interior noise for cylindrical models of aircraft fuselages for prescribed exterior noise fields. Phase 2: Models for sidewall trim, stiffened structures and cabin acoustics with floor partition

    NASA Technical Reports Server (NTRS)

    Pope, L. D.; Wilby, E. G.

    1982-01-01

    An airplane interior noise prediction model is developed to determine the important parameters associated with sound transmission into the interiors of airplanes, and to identify apropriate noise control methods. Models for stiffened structures, and cabin acoustics with floor partition are developed. Validation studies are undertaken using three test articles: a ring stringer stiffened cylinder, an unstiffened cylinder with floor partition, and ring stringer stiffened cylinder with floor partition and sidewall trim. The noise reductions of the three test articles are computed using the heoretical models and compared to measured values. A statistical analysis of the comparison data indicates that there is no bias in the predictions although a substantial random error exists so that a discrepancy of more than five or six dB can be expected for about one out of three predictions.

  15. The Great Oil Spill Cleanup Contest.

    ERIC Educational Resources Information Center

    Hampton, Elaine

    1993-01-01

    Presents an exciting way to acquaint students with current methods to clean up oil spills. Students also have the freedom to create new clean-up methods as they think through the problem and experiment to find effective solutions. (PR)

  16. Pelvic Floor Dynamics During High-Impact Athletic Activities: A Computational Modeling Study

    PubMed Central

    Dias, Nicholas; Peng, Yun; Khavari, Rose; Nakib, Nissrine A.; Sweet, Robert M.; Timm, Gerald W.; Erdman, Arthur G.; Boone, Timothy B.

    2017-01-01

    Background Stress urinary incontinence is a significant problem in young female athletes, but the pathophysiology remains unclear because of the limited knowledge of the pelvic floor support function and limited capability of currently available assessment tools. The aim of our study is to develop an advanced computer modeling tool to better understand the dynamics of the internal pelvic floor during highly transient athletic activities. Methods Apelvic model was developed based on high-resolution MRI scans of a healthy nulliparous young female. A jump-landing process was simulated using realistic boundary conditions captured from jumping experiments. Hypothesized alterations of the function of pelvic floor muscles were simulated by weakening or strengthening the levator ani muscle stiffness at different levels. Intra-abdominal pressures and corresponding deformations of pelvic floor structures were monitored at different levels of weakness or enhancement. Findings Results show that pelvic floor deformations generated during a jump-landing process differed greatly from those seen in a Valsalva maneuver which is commonly used for diagnosis in clinic. The urethral mobility was only slightly influenced by the alterations of the levator ani muscle stiffness. Implications for risk factors and treatment strategies were also discussed. Interpretation Results suggest that clinical diagnosis should make allowances for observed differences in pelvic floor deformations between a Valsalva maneuver and a jump-landing process to ensure accuracy. Urethral hypermobility may be a less contributing factor than the intrinsic sphincteric closure system to the incontinence of young female athletes. PMID:27886590

  17. Life cycle contributions of copper from vessel painting and maintenance activities

    PubMed Central

    Earley, Patrick J.; Swope, Brandon L.; Barbeau, Katherine; Bundy, Randelle; McDonald, Janessa A.; Rivera-Duarte, Ignacio

    2013-01-01

    Copper-based epoxy and ablative antifouling painted panels were exposed in natural seawater to evaluate environmental loading parameters. In situ loading factors including initial exposure, passive leaching, and surface refreshment were measured utilizing two protocols developed by the US Navy: the dome method and the in-water hull cleaning sampling method. Cleaning techniques investigated included a soft-pile carpet and a medium duty 3M™ pad for fouling removal. Results show that the passive leach rates of copper peaked three days after both initial deployment and cleaning events (CEs), followed by a rapid decrease over about 15 days and a slow approach to asymptotic levels on approximately day 30. Additionally, copper was more bioavailable during a CE in comparison to the passive leaching that immediately followed. A paint life cycle model quantifying annual copper loading estimates for each paint and cleaning method based on a three-year cycle of painting, episodic cleaning, and passive leaching is presented. PMID:24199998

  18. Cleaning a semipermeable membrane in a papermaking machine

    DOEpatents

    Beck, David A.

    2004-01-06

    A method of cleaning a semipermeable membrane, the semipermeable membrane being configured for carrying a fiber web, includes the steps of providing a cleaning fluid and applying the cleaning fluid on the semipermeable membrane. Further, an air press configured for carrying the semipermeable membrane therethrough is provided, and the air press has pressurized air therein. The semipermeable membrane is conveyed through the air press and is subjected to the pressurized air within the air press. The pressurized air thereby flushes the cleaning fluid through the semipermeable membrane.

  19. Evaluation of Non-Ozone-Depleting-Chemical Cleaning Methods for Space Mechanisms Using a Vacuum Spiral Orbit Rolling Contact Tribometer

    NASA Technical Reports Server (NTRS)

    Jansen, Mark J.; Jones, William R., Jr.; Wheeler, Donald R.; Keller, Dennis J.

    2000-01-01

    Because CFC 113, an ozone depleting chemical (ODC), can no longer be produced, alternative bearing cleaning methods must be studied. The objective of this work was to study the effect of the new cleaning methods on lubricant lifetime using a vacuum bearing simulator (spiral orbit rolling contact tribometer). Four alternative cleaning methods were studied: ultra-violet (UV) ozone, aqueous levigated alumina slurry (ALAS), super critical fluid (SCF) CO2 and aqueous Brulin 815GD. Baseline tests were done using CFC 113. Test conditions were the following: a vacuum of at least 1.3 x 10(exp -6) Pa, 440C steel components, a rotational speed of 10 RPM, a lubricant charge of between 60-75 micrograms, a perfluoropolyalkylether lubricant (Z-25), and a load of 200N (44.6 lbs., a mean Hertzian stress of 1.5 GPa). Normalized lubricant lifetime was determined by dividing the total number of ball orbits by the amount of lubricant. The failure condition was a friction coefficient of 0.38. Post-test XPS analysis was also performed, showing slight variations in post-cleaning surface chemistry. Statistical analysis of the resultant data was conducted and it was determined that the data sets were most directly comparable when subjected to a natural log transformation. The natural log life (NL-Life) data for each cleaning method were reasonably normally (statistically) distributed and yielded standard deviations that were not significantly different among the five cleaning methods investigated. This made comparison of their NL-Life means very straightforward using a Bonferroni multiple comparison of means procedure. This procedure showed that the ALAS, UV-ozone and CFC 113 methods were not statistically significantly different from one another with respect to mean NL-Life. It also found that the SCF CO2 method yielded a significantly higher mean NL-Life than the mean NL-Lives of the ALAS, UV-ozone and CFC 113 methods. It also determined that the aqueous Brulin 815GD method yielded a mean NL-Life that was statistically significantly higher than the mean NL-Lives of each of the other four methods. Baseline tests using CFC 113 cleaned parts yielded a mean NL-Life 3.62 orbits/micro-g. ALAS and UV-ozone yielded similar mean NL-Life (3.31 orbits/mg and 3.33 orbits/micro-g, respectively). SCF CO2, gave a mean NL-Life of 4.08 orbits/mg and aqueous Brulin 8l5GD data yielded the longest mean NL-Life (4.66 orbits/micro-g).

  20. Use of history science methods in exposure assessment for occupational health studies.

    PubMed

    Johansen, K; Tinnerberg, H; Lynge, E

    2005-07-01

    To show the power of history science methods for exposure assessment in occupational health studies, using the dry cleaning industry in Denmark around 1970 as the example. Exposure data and other information on exposure status were searched for in unconventional data sources such as the Danish National Archives, the Danish Royal Library, archives of Statistics Denmark, the National Institute of Occupational Health, Denmark, and the Danish Labor Inspection Agency. Individual census forms were retrieved from the Danish National Archives. It was estimated that in total 3267 persons worked in the dry cleaning industry in Denmark in 1970. They typically worked in small shops with an average size of 3.5 persons. Of these, 2645 persons were considered exposed to solvents as they were dry cleaners or worked very close to the dry cleaning process, while 622 persons were office workers, drivers, etc in shops with 10 or more persons. It was estimated that tetrachloroethylene constituted 85% of the dry cleaning solvent used, and that a shop would normally have two machines using 4.6 tons of tetrachloroethylene annually. The history science methods, including retrieval of material from the Danish National Archives and a thorough search in the Royal Library for publications on dry cleaning, turned out to be a very fruitful approach for collection of exposure data on dry cleaning work in Denmark. The history science methods proved to be a useful supplement to the exposure assessment methods normally applied in epidemiological studies.

  1. Pelvic Floor Disorders After Childbirth: Effect of Episiotomy, Perineal Laceration, and Operative Birth

    PubMed Central

    Handa, Victoria L.; Blomquist, Joan L.; McDermott, Kelly C.; Friedman, Sarah; Muñoz, Alvaro

    2011-01-01

    Objective To investigate whether episiotomy, perineal laceration, and operative delivery are associated with pelvic floor disorders after vaginal childbirth. Methods This is a planned analysis of data for a cohort study of pelvic floor disorders. Participants who had experienced at least one vaginal birth were recruited 5–10 years after delivery of their first child. Obstetric exposures were classified by review of hospital records. At enrollment, pelvic floor outcomes, including stress incontinence, overactive bladder, anal incontinence, and prolapse symptoms were assessed with a validated questionnaire. Pelvic organ support was assessed using the Pelvic Organ Prolapse Quantification system. Logistic regression analysis was used to estimate the relative odds of each pelvic floor disorder by obstetric history, adjusting for relevant confounders. Results Of 449 participants, 71 (16%) had stress incontinence, 45 (10%) had overactive bladder, 56 (12%) had anal incontinence, 19 (4%) had prolapse symptoms and 64 (14%) had prolapse to or beyond the hymen on examination. Forceps delivery increased the odds of each pelvic floor disorder considered, especially overactive bladder (odds ratio 2.92, 95% confidence interval 1.44, 5.93) and prolapse (odds ratio 1.95, 95% confidence interval 1.03, 3.70). Episiotomy was not associated with any of these pelvic floor disorders. In contrast, women with a history of more than one spontaneous perineal laceration were significantly more likely to have prolapse to or beyond the hymen (odds ratio 2.34, 95% confidence interval 1.13, 4.86). Our multivariable results suggest that one additional woman would develop prolapse for every 8 women who experienced at least one forceps birth (versus delivering all her children by spontaneous vaginal birth). Conclusion Forceps deliveries and perineal lacerations, but not episiotomies, were associated with pelvic floor disorders 5–10 years after a first delivery. PMID:22227639

  2. Fungal extracellular polysaccharides in house dust as a marker for exposure to fungi: relations with culturable fungi, reported home dampness, and respiratory symptoms.

    PubMed

    Douwes, J; van der Sluis, B; Doekes, G; van Leusden, F; Wijnands, L; van Strien, R; Verhoeff, A; Brunekreef, B

    1999-03-01

    Epidemiologic studies have demonstrated an association between indoor fungal growth and respiratory symptoms. However, in only a few studies was fungal exposure actually measured. The purpose of this study was to evaluate the measurement by enzyme immunoassay of extracellular polysaccharides of Aspergillus and Penicillium species (EPS-Asp/Pen ) in house dust as a marker for fungal exposure and to study the relations between EPS-Asp/Pen levels and home dampness and respiratory symptoms in children. Extracts of house dust samples from bedroom and living room floors and mattresses from homes of 31 children with chronic respiratory symptoms and 29 children with no chronic respiratory symptoms were analyzed for EPS-Asp/Pen. EPS-Asp/Pen were readily detectable (40 to 46,513 nanogram equivalent/g dust) in 161 house dust extracts, with highest concentrations in living room floor dust. EPS-Asp/Pen levels were 2 to 3 times higher on carpeted floors than on smooth floors. EPS-Asp/Pen were significantly correlated with total culturable fungi (r = 0.3 to 0.5) and with house dust mite allergens (r = 0.3 to 0.5). EPS-Asp/Pen levels in living room floor dust were positively associated with occupant-reported home dampness. This was not observed for EPS-Asp/Pen in bedroom floor and mattress dust. EPS-Asp/Pen levels in living room floor dust were positively associated with respiratory symptoms. EPS-Asp/Pen in bedroom floor and mattress dust showed a reversed association with respiratory symptoms, possibly because of allergen-avoidance measures taken in the bedroom. The enzyme immunoassay for fungal EPS-Asp/Pen may be a useful method for exposure assessment of indoor fungi.

  3. Traditional Gymnastic Exercises for the Pelvic Floor Often Lead to Bladder Neck Descent - a Study Using Perineal Ultrasound.

    PubMed

    Baeßler, Kaven; Junginger, Bärbel

    2017-07-01

    The aims of physiotherapy in stress incontinent women are to improve pelvic floor function and the continence mechanism including bladder neck support and urethral closure pressure. In Germany, traditional conservative treatment often includes gymnastic exercises with unclear effects on the bladder neck. The aim of this study was to sonographically assess bladder neck movements during selected exercises. Fifteen healthy, continent women without previous vaginal births, who were able to voluntarily contract their pelvic floor muscels performed the shoulder bridge, the abdominal press, tiptoe and the Pilates clam exercises. The first set was performed without any additional instructions. During the second set directions were given to activate the pelvic floor before beginning each exercise and to maintain the contraction throughout the exercise. Bladder neck movement was measured on perineal ultrasound using a validated method with the pubic symphysis as a reference point. The median age of participants was 32 years, median BMI was 23. Eight women were nulliparous and seven had given birth to 1 - 2 children via caesarean section. When exercises were performed without voluntary pelvic floor contraction the bladder neck descended on average between 2.3 and 4.4 mm, and with pelvic floor contraction prior to the exercise only between 0.5 and 2.1 mm (p > 0.05 except for abdominal press p = 0.007). The Pilates clam exercise and toe stand stabilised the bladder neck most effectively. Bladder neck descent often occurs during pelvic floor gymnastic exercises as traditionally performed in Germany, and a voluntary pelvic floor contraction during the exercises does not necessarily prevent this.

  4. Used Solvent Testing and Reclamation. Volume 1. Cold-Cleaning Solvents

    DTIC Science & Technology

    1988-12-01

    spectrometer, and specific gravity meter involve buying routine cleaning supplies , and should not exceed $50. Consequently, these methods were...in addition to routine cleaning supplies . The K13V measurement requires periodic supplies of Kauri-butanol solution. TLC analysis requires glass

  5. Hazardous Waste: Cleanup and Prevention.

    ERIC Educational Resources Information Center

    Vandas, Steve; Cronin, Nancy L.

    1996-01-01

    Discusses hazardous waste, waste disposal, unsafe exposure, movement of hazardous waste, and the Superfund clean-up process that consists of site discovery, site assessment, clean-up method selection, site clean up, and site maintenance. Argues that proper disposal of hazardous waste is everybody's responsibility. (JRH)

  6. Ozone Generators That Are Sold as Air Cleaners

    MedlinePlus

    ... U.S. EPA, 1996a). Top of Page What Other Methods Can Be Used to Control Indoor Air Pollution? ... Air Cleaning: Remove pollutants through proven air cleaning methods. Of the three, the first approach — source control — ...

  7. 40 CFR 60.3067 - How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.3067 Section 60.3067... Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3067 How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a) Use Method 9 of...

  8. 40 CFR 60.3067 - How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.3067 Section 60.3067... Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3067 How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a) Use Method 9 of...

  9. 40 CFR 60.3067 - How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.3067 Section 60.3067... Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3067 How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a) Use Method 9 of...

  10. 40 CFR 60.3067 - How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.3067 Section 60.3067... Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3067 How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a) Use Method 9 of...

  11. 40 CFR 60.3067 - How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.3067 Section 60.3067... Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3067 How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a) Use Method 9 of...

  12. 40 CFR 62.14820 - How must I monitor opacity for air curtain incinerators that burn 100 percent wood wastes, clean...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... curtain incinerators that burn 100 percent wood wastes, clean lumber, and/or yard waste? 62.14820 Section... Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or... wood wastes, clean lumber, and/or yard waste? (a) Use Method 9 of 40 CFR part 60, Appendix A to...

  13. 40 CFR 62.14820 - How must I monitor opacity for air curtain incinerators that burn 100 percent wood wastes, clean...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... curtain incinerators that burn 100 percent wood wastes, clean lumber, and/or yard waste? 62.14820 Section... Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or... wood wastes, clean lumber, and/or yard waste? (a) Use Method 9 of 40 CFR part 60, Appendix A to...

  14. Stability of reference masses: VII. Cleaning methods in air and vacuum applied to a platinum mass standard similar to the international and national kilogram prototypes

    NASA Astrophysics Data System (ADS)

    Cumpson, Peter J.; Sano, Naoko; Barlow, Anders J.; Portoles, Jose F.

    2013-10-01

    Mercury contamination and the build-up of carbonaceous contamination are two contributing factors to the instability observed in kilogram prototype masses. The kilogram prototypes that lie at the core of the dissemination of the SI base unit were manufactured in the late 19th century, and have polished surfaces. In papers IV and V of this series we developed a method for cleaning noble metal mass standards in air to remove carbonaceous contamination. At the core of this ‘UVOPS’ protocol is the application of UV light and ozone gas generated in situ in air. The precise nature of the carbonaceous contamination that builds up on such surfaces is difficult to mimic demonstrably or quickly on new test surfaces, yet data from such tests are needed to provide the final confidence to allow UVOPS to be applied to a real 19th century kilogram prototype. Therefore, in the present work we have applied the UVOPS method to clean a platinum avoirdupois pound mass standard, ‘RS2’, manufactured in the mid-19th century. This is thought to have been polished in a similar manner to the kilogram prototypes. To our knowledge this platinum surface has not previously been cleaned by any method. We used x-ray photoelectron spectroscopy to identify organic contamination, and weighing to quantify the mass lost at each application of the UVOPS procedure. The UVOPS procedure is shown to be very effective. It is likely that the redefinition of the kilogram will require mass comparisons in vacuum in the years to come. Therefore, in addition to UVOPS a cleaning method for use in vacuum will also be needed. We introduce and evaluate gas cluster ion-beam (GCIB) treatment as a potential method for cleaning reference masses in vacuum. Again, application of this GCIB cleaning to a real artefact, RS2, allows us to make a realistic evaluation of its performance. While it has some attractive features, we cannot recommend it for cleaning mass standards in its present form.

  15. Virtual reality: new method of teaching anorectal and pelvic floor anatomy.

    PubMed

    Dobson, Howard D; Pearl, Russell K; Orsay, Charles P; Rasmussen, Mary; Evenhouse, Ray; Ai, Zhuming; Blew, Gregory; Dech, Fred; Edison, Marcia I; Silverstein, Jonathan C; Abcarian, Herand

    2003-03-01

    A clear understanding of the intricate spatial relationships among the structures of the pelvic floor, rectum, and anal canal is essential for the treatment of numerous pathologic conditions. Virtual-reality technology allows improved visualization of three-dimensional structures over conventional media because it supports stereoscopic-vision, viewer-centered perspective, large angles of view, and interactivity. We describe a novel virtual reality-based model designed to teach anorectal and pelvic floor anatomy, pathology, and surgery. A static physical model depicting the pelvic floor and anorectum was created and digitized at 1-mm intervals in a CT scanner. Multiple software programs were used along with endoscopic images to generate a realistic interactive computer model, which was designed to be viewed on a networked, interactive, virtual-reality display (CAVE or ImmersaDesk). A standard examination of ten basic anorectal and pelvic floor anatomy questions was administered to third-year (n = 6) and fourth-year (n = 7) surgical residents. A workshop using the Virtual Pelvic Floor Model was then given, and the standard examination was readministered so that it was possible to evaluate the effectiveness of the Digital Pelvic Floor Model as an educational instrument. Training on the Virtual Pelvic Floor Model produced substantial improvements in the overall average test scores for the two groups, with an overall increase of 41 percent (P = 0.001) and 21 percent (P = 0.0007) for third-year and fourth-year residents, respectively. Resident evaluations after the workshop also confirmed the effectiveness of understanding pelvic anatomy using the Virtual Pelvic Floor Model. This model provides an innovative interactive educational framework that allows educators to overcome some of the barriers to teaching surgical and endoscopic principles based on understanding highly complex three-dimensional anatomy. Using this collaborative, shared virtual-reality environment, teachers and students can interact from locations world-wide to manipulate the components of this model to achieve the educational goals of this project along with the potential for virtual surgery.

  16. Performing a urine dipstick test with a clean-catch urine sample is an accurate screening method for urinary tract infections in young infants.

    PubMed

    Herreros, María Luisa; Tagarro, Alfredo; García-Pose, Araceli; Sánchez, Aida; Cañete, Alfonso; Gili, Pablo

    2018-01-01

    This study evaluated using urine dipstick tests with the clean-catch method to screen for urinary tract infection (UTI) in febrile infants under 90 days of age. We carried out a comparative diagnostic accuracy study of infants under 90 days old, who were studied for unexplained fever without any source, in the emergency room of a hospital in Madrid from January 2011 to January 2013. We obtained matched samples of urine using two different methods: a clean-catch, standardised stimulation technique and catheterisation collection. The results of the leucocyte esterase test and nitrite test were compared with their urine cultures. We obtained 60 pairs of matched samples. A combined analysis of leukocyte esterase and, or, nitrites yielded a sensitivity of 86% and a specificity of 80% for the diagnosis of UTIs in clean-catch samples. The sensitivity of leukocyte esterase and, or, nitrites in samples obtained by catheterisation were not statistically different to the clean-catch samples (p = 0.592). Performing urine dipstick tests using urine samples obtained by the clean-catch method was an accurate screening test for diagnosing UTIs in febrile infants of less than 90 days old. This provided a good alternative to bladder catheterisation when screening for UTIs. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  17. Impact localization in dispersive waveguides based on energy-attenuation of waves with the traveled distance

    NASA Astrophysics Data System (ADS)

    Alajlouni, Sa'ed; Albakri, Mohammad; Tarazaga, Pablo

    2018-05-01

    An algorithm is introduced to solve the general multilateration (source localization) problem in a dispersive waveguide. The algorithm is designed with the intention of localizing impact forces in a dispersive floor, and can potentially be used to localize and track occupants in a building using vibration sensors connected to the lower surface of the walking floor. The lower the wave frequencies generated by the impact force, the more accurate the localization is expected to be. An impact force acting on a floor, generates a seismic wave that gets distorted as it travels away from the source. This distortion is noticeable even over relatively short traveled distances, and is mainly caused by the dispersion phenomenon among other reasons, therefore using conventional localization/multilateration methods will produce localization error values that are highly variable and occasionally large. The proposed localization approach is based on the fact that the wave's energy, calculated over some time window, decays exponentially as the wave travels away from the source. Although localization methods that assume exponential decay exist in the literature (in the field of wireless communications), these methods have only been considered for wave propagation in non-dispersive media, in addition to the limiting assumption required by these methods that the source must not coincide with a sensor location. As a result, these methods cannot be applied to the indoor localization problem in their current form. We show how our proposed method is different from the other methods, and that it overcomes the source-sensor location coincidence limitation. Theoretical analysis and experimental data will be used to motivate and justify the pursuit of the proposed approach for localization in a dispersive medium. Additionally, hammer impacts on an instrumented floor section inside an operational building, as well as finite element model simulations, are used to evaluate the performance of the algorithm. It is shown that the algorithm produces promising results providing a foundation for further future development and optimization.

  18. Examining factors that influence the effectiveness of cleaning antineoplastic drugs from drug preparation surfaces: a pilot study.

    PubMed

    Hon, Chun-Yip; Chua, Prescillia Ps; Danyluk, Quinn; Astrakianakis, George

    2014-06-01

    Occupational exposure to antineoplastic drugs has been documented to result in various adverse health effects. Despite the implementation of control measures to minimize exposure, detectable levels of drug residual are still found on hospital work surfaces. Cleaning these surfaces is considered as one means to minimize the exposure potential. However, there are no consistent guiding principles related to cleaning of contaminated surfaces resulting in hospitals to adopt varying practices. As such, this pilot study sought to evaluate current cleaning protocols and identify those factors that were most effective in reducing contamination on drug preparation surfaces. Three cleaning variables were examined: (1) type of cleaning agent (CaviCide®, Phenokil II™, bleach and chlorhexidine), (2) application method of cleaning agent (directly onto surface or indirectly onto a wipe) and (3) use of isopropyl alcohol after cleaning agent application. Known concentrations of antineoplastic drugs (either methotrexate or cyclophosphamide) were placed on a stainless steel swatch and then, systematically, each of the three cleaning variables was tested. Surface wipes were collected and quantified using high-performance liquid chromatography-tandem mass spectrometry to determine the percent residual of drug remaining (with 100% being complete elimination of the drug). No one single cleaning agent proved to be effective in completely eliminating all drug contamination. The method of application had minimal effect on the amount of drug residual. In general, application of isopropyl alcohol after the use of cleaning agent further reduced the level of drug contamination although measureable levels of drug were still found in some cases.

  19. Validation of adenosine triphosphate to audit manual cleaning of flexible endoscope channels.

    PubMed

    Alfa, Michelle J; Fatima, Iram; Olson, Nancy

    2013-03-01

    Compliance with cleaning of flexible endoscope channels cannot be verified using visual inspection. Adenosine triphosphate (ATP) has been suggested as a possible rapid cleaning monitor for flexible endoscope channels. There have not been published validation studies to specify the level of ATP that indicates inadequate cleaning has been achieved. The objective of this study was to validate the Clean-Trace (3M Inc, St. Paul, MN) ATP water test method for monitoring manual cleaning of flexible endoscopes. This was a simulated use study using a duodenoscope as the test device. Artificial test soil containing 10(6) colony-forming units of Pseudomonas aeruginosa and Enterococcus faecalis was used to perfuse all channels. The flush sample method for the suction-biopsy (L1) or air-water channel (L2) using 40 and 20 mLs sterile reverse osmosis water, respectively, was validated. Residuals of ATP, protein, hemoglobin, and bioburden were quantitated from channel samples taken from uncleaned, partially cleaned, and fully cleaned duodenoscopes. The benchmarks for clean were as follows: <6.4 μg/cm(2) protein, <2.2 μg/cm(2) hemoglobin, and <4-log10 colony-forming units/cm(2) bioburden. The average ATP in clean channel samples was 27.7 RLUs and 154 RLUs for L1 and L2, respectively (<200 RLUs for all channels). The average protein, hemoglobin, and bioburden benchmarks were achieved if <200 RLUs were detected. If the channel sample was >200 RLUs, the residual organic and bioburden levels would exceed the acceptable benchmarks. Our data validated that flexible endoscopes that have complete manual cleaning will have <200 RLUs by the Clean-Trace ATP test. Copyright © 2013 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  20. The Cleaning of the Parthenon West Frieze by Means of Combined IR- and UV-Radiation

    NASA Astrophysics Data System (ADS)

    Frantzikinaki, K.; Marakis, G.; Panou, A.; Vasiliadis, C.; Papakonstantinou, E.; Pouli, P.; Ditsa, T.; Zafiropulos, Vassilis; Fotakis, Costas

    This chapter deals with the cleaning of the Parthenon West Frieze by means of an innovative laser cleaning methodology. Following a comparative study of various cleaning methods, laser cleaning was proven to be the most efficient method for the removal of loose deposits and black crusts. The laser system employed is a Q-switched Nd:YAG system emitting at the fundamental and the third harmonic frequencies designed and developed by FORTH-IESL. The system emits in two wavelength beams individually or in combination. This feature, along with possible modification of the laser parameters - energy density, number of pulses, the contribution of each beam to the final combined beam - for each individual case of encrustation and substrate (marble, monochromatic layers), leads to a safe and controlled cleaning result. The project commenced in 2002 and was completed in January 2005. Since then, the Parthenon West Frieze is on display at the Acropolis Museum in Athens, Greece.

  1. Effects of electrolyzed oxidizing water on reducing Listeria monocytogenes contamination on seafood processing surfaces.

    PubMed

    Liu, Chengchu; Duan, Jingyun; Su, Yi-Cheng

    2006-02-15

    The effects of electrolyzed oxidizing (EO) water on reducing Listeria monocytogenes contamination on seafood processing surfaces were studied. Chips (5 x 5 cm(2)) of stainless steel sheet (SS), ceramic tile (CT), and floor tile (FT) with and without crabmeat residue on the surface were inoculated with L. monocytogenes and soaked in tap or EO water for 5 min. Viable cells of L. monocytogenes were detected on all chip surfaces with or without crabmeat residue after being held at room temperature for 1 h. Soaking contaminated chips in tap water resulted in small-degree reductions of the organism (0.40-0.66 log cfu/chip on clean surfaces and 0.78-1.33 log cfu/chip on dirty surfaces). Treatments of EO water significantly (p<0.05) reduced L. monocytogenes on clean surfaces (3.73 log on SS, 4.24 log on CT, and 5.12 log on FT). Presence of crabmeat residue on chip surfaces reduced the effectiveness of EO water on inactivating Listeria cells. However, treatments of EO water also resulted in significant reductions of L. monocytogenes on dirty surfaces (2.33 log on SS and CT and 1.52 log on FT) when compared with tap water treatments. The antimicrobial activity of EO water was positively correlated with its chlorine content. High oxidation-reduction potential (ORP) of EO water also contributed significantly to its antimicrobial activity against L. monocytogenes. EO water was more effective than chlorine water on inactivating L. monocytogenes on surfaces and could be used as a chlorine alternative for sanitation purpose. Application of EO water following a thorough cleaning process could greatly reduce L. monocytogenes contamination in seafood processing environments.

  2. Gold cleaning methods for preparation of cell culture surfaces for self-assembled monolayers of zwitterionic oligopeptides.

    PubMed

    Enomoto, Junko; Kageyama, Tatsuto; Myasnikova, Dina; Onishi, Kisaki; Kobayashi, Yuka; Taruno, Yoko; Kanai, Takahiro; Fukuda, Junji

    2018-05-01

    Self-assembled monolayers (SAMs) have been used to elucidate interactions between cells and material surface chemistry. Gold surfaces modified with oligopeptide SAMs exhibit several unique characteristics, such as cell-repulsive surfaces, micropatterns of cell adhesion and non-adhesion regions for control over cell microenvironments, and dynamic release of cells upon external stimuli under culture conditions. However, basic procedures for the preparation of oligopeptide SAMs, including appropriate cleaning methods of the gold surface before modification, have not been fully established. Because gold surfaces are readily contaminated with organic compounds in the air, cleaning methods may be critical for SAM formation. In this study, we examined the effects of four gold cleaning methods: dilute aqua regia, an ozone water, atmospheric plasma, and UV irradiation. Among the methods, UV irradiation most significantly improved the formation of oligopeptide SAMs in terms of repulsion of cells on the surfaces. We fabricated an apparatus with a UV light source, a rotation table, and HEPA filter, to treat a number of gold substrates simultaneously. Furthermore, UV-cleaned gold substrates were capable of detaching cell sheets without serious cell injury. This may potentially provide a stable and robust approach to oligopeptide SAM-based experiments for biomedical studies. Copyright © 2017 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  3. Contamination mitigation strategies for scanning transmission electron microscopy.

    PubMed

    Mitchell, D R G

    2015-06-01

    Modern scanning transmission electron microscopy (STEM) enables imaging and microanalysis at very high magnification. In the case of aberration-corrected STEM, atomic resolution is readily achieved. However, the electron fluxes used may be up to three orders of magnitude greater than those typically employed in conventional STEM. Since specimen contamination often increases with electron flux, specimen cleanliness is a critical factor in obtaining meaningful data when carrying out high magnification STEM. A range of different specimen cleaning methods have been applied to a variety of specimen types. The contamination rate has been measured quantitatively to assess the effectiveness of cleaning. The methods studied include: baking, cooling, plasma cleaning, beam showering and UV/ozone exposure. Of the methods tested, beam showering is rapid, experimentally convenient and very effective on a wide range of specimens. Oxidative plasma cleaning is also very effective and can be applied to specimens on carbon support films, albeit with some care. For electron beam-sensitive materials, cooling may be the method of choice. In most cases, preliminary removal of the bulk of the contamination by methods such as baking or plasma cleaning, followed by beam showering, where necessary, can result in a contamination-free specimen suitable for extended atomic scale imaging and analysis. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Dietary supplementation with a nucleotide-rich yeast extract modulates gut immune response and microflora in weaned pigs in response to a sanitary challenge.

    PubMed

    Waititu, S M; Yin, F; Patterson, R; Yitbarek, A; Rodriguez-Lecompte, J C; Nyachoti, C M

    2017-12-01

    An experiment was carried out to evaluate the short-term effect of supplementing a nucleotide-rich yeast extract (NRYE) on growth performance, gut structure, immunity and microflora of piglets raised under sanitary and unsanitary conditions. A total of 84, 21-day old piglets were used in this study; 42 piglets were raised in a room designated as the clean room that was washed once per week, whereas the other 42 piglets were raised in a room designated as the unclean room in which 7 kg of manure from the sow herd was spread on each pen floor on day 1 and 7 and the room was not washed throughout the experiment. The pigs were fed a corn-soybean meal-based diet without or with 0.1% NRYE. Each treatment had 7 replicate pens in each room, and each pen housed 3 pigs. Feed disappearance and BW were recorded on day 1 and 14. On day 14, one pig per pen was euthanized to collect ileum, mesenteric lymph nodes and spleen tissues, and cecum and colon digesta. Overall, NRYE supplementation did not affect growth performance in both clean and unclean conditions, improved kidney weight in both clean (P=0.0002) and unclean room (P<0.0001) and tended to improve the villus height/crypt depth ratio in the clean room (P=0.073). Supplementing NRYE was associated with upregulation of Ileal programmed cell death gene-1 (P=0.0003), interleukin (IL)-1β (P<0.0001), IL-6 (P=0.0003), IL-10 (P<0.0001) and tumor necrosis factor-α (TNF-α) (P<0.0001) in pigs raised in the unclean room. Supplementing the NRYE in pigs raised in the clean room suppressed growth of cecal Enterobacteriacea (P<0.0001) members and colonic Enterococcus spp. (P<0.019), improved proliferation of cecal Lactobacillus spp. (P<0.002) and colonic Clostridium cluster IV (P<0.011) and XVIa members (P<0.0002). Supplementing the NRYE in the unclean room improved proliferation of cecal Clostridium cluster IV (P<0.026) and suppressed proliferation of colonic Enterococcus spp. (P<0.037). In conclusion, supplementing the NRYE to piglets under unsanitary conditions improved ileal immune response by upregulating inflammatory cytokines, and positively modulated proliferation of beneficial gut bacteria and suppression of harmful ones in both clean and unclean rooms.

  5. Structure having spatially separated photo-excitable electron-hole pairs and method of manufacturing same

    DOEpatents

    Liang, Yong [Richland, WA; Daschbach, John L [Richland, WA; Su, Yali [Richland, WA; Chambers, Scott A [Kennewick, WA

    2006-08-22

    A method for producing quantum dots. The method includes cleaning an oxide substrate and separately cleaning a metal source. The substrate is then heated and exposed to the source in an oxygen environment. This causes metal oxide quantum dots to form on the surface of the substrate.

  6. Structure having spatially separated photo-excitable electron-hole pairs and method of manufacturing same

    DOEpatents

    Liang, Yong [Richland, WA; Daschbach, John L [Richland, WA; Su, Yali [Richland, WA; Chambers, Scott A [Kennewick, WA

    2003-03-18

    A method for producing quantum dots. The method includes cleaning an oxide substrate and separately cleaning a metal source. The substrate is then heated and exposed to the source in an oxygen environment. This causes metal oxide quantum dots to form on the surface of the substrate.

  7. Safe, Affordable, Convenient: Environmental Features of Malls and Other Public Spaces Used by Older Adults for Walking

    PubMed Central

    King, Diane K.; Allen, Peg; Jones, Dina L.; Marquez, David X.; Brown, David R.; Rosenberg, Dori; Janicek, Sarah; Allen, Laila; Belza, Basia

    2016-01-01

    Background Midlife and older adults use shopping malls for walking, but little research has examined mall characteristics that contribute to their walkability. Methods We used modified versions of the Centers for Disease Control and Prevention (CDC)-Healthy Aging Research Network (HAN) Environmental Audit and the System for Observing Play and Recreation in Communities (SOPARC) tool to systematically observe 443 walkers in 10 shopping malls. We also observed 87 walkers in 6 community-based nonmall/nongym venues where older adults routinely walked for physical activity. Results All venues had public transit stops and accessible parking. All malls and 67% of nonmalls had wayfinding aids, and most venues (81%) had an established circuitous walking route and clean, well-maintained public restrooms (94%). All venues had level floor surfaces, and one-half had benches along the walking route. Venues varied in hours of access, programming, tripping hazards, traffic control near entrances, and lighting. Conclusions Despite diversity in location, size, and purpose, the mall and nonmall venues audited shared numerous environmental features known to promote walking in older adults and few barriers to walking. Future research should consider programmatic features and outreach strategies to expand the use of malls and other suitable public spaces for walking. PMID:26181907

  8. Method for assessing coal-floor water-inrush risk based on the variable-weight model and unascertained measure theory

    NASA Astrophysics Data System (ADS)

    Wu, Qiang; Zhao, Dekang; Wang, Yang; Shen, Jianjun; Mu, Wenping; Liu, Honglei

    2017-11-01

    Water inrush from coal-seam floors greatly threatens mining safety in North China and is a complex process controlled by multiple factors. This study presents a mathematical assessment system for coal-floor water-inrush risk based on the variable-weight model (VWM) and unascertained measure theory (UMT). In contrast to the traditional constant-weight model (CWM), which assigns a fixed weight to each factor, the VWM varies with the factor-state value. The UMT employs the confidence principle, which is more effective in ordered partition problems than the maximum membership principle adopted in the former mathematical theory. The method is applied to the Datang Tashan Coal Mine in North China. First, eight main controlling factors are selected to construct the comprehensive evaluation index system. Subsequently, an incentive-penalty variable-weight model is built to calculate the variable weights of each factor. Then, the VWM-UMT model is established using the quantitative risk-grade divide of each factor according to the UMT. On this basis, the risk of coal-floor water inrush in Tashan Mine No. 8 is divided into five grades. For comparison, the CWM is also adopted for the risk assessment, and a differences distribution map is obtained between the two methods. Finally, the verification of water-inrush points indicates that the VWM-UMT model is powerful and more feasible and reasonable. The model has great potential and practical significance in future engineering applications.

  9. Method and apparatus for recovering a gas from a gas hydrate located on the ocean floor

    DOEpatents

    Wyatt, Douglas E.

    2001-01-01

    A method and apparatus for recovering a gas from a gas hydrate on the ocean floor includes a flexible cover, a plurality of steerable base members secured to the cover, and a steerable mining module. A suitable source for inflating the cover over the gas hydrate deposit is provided. The mining module, positioned on the gas hydrate deposit, is preferably connected to the cover by a control cable. A gas retrieval conduit or hose extends upwardly from the cover to be connected to a support ship on the ocean surface.

  10. A method for preparation and cleaning of uniformly sized arsenopyrite particles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parthasarathy, Hariprasad; Baltrus, John P; Dzombak, David A

    The oxidative dissolution of sulfide minerals, such as arsenopyrite (FeAsS), is of critical importance in many geochemical systems. A comprehensive understanding of their dissolution rates entails careful preparation of the mineral surface. Measurements of dissolution rates of arsenic from arsenopyrite are dependent on the size and degree of oxidation of its particles, among other factors. In this work, a method was developed for preparation and cleaning of arsenopyrite particles with size range of 150–250 μm. Four different cleaning methods were evaluated for effectiveness based on the removal of oxidized species of iron (Fe), arsenic (As) and sulfur (S) from themore » surface. The percentage oxidation of the surface was determined using X-ray photoelectron spectroscopy (XPS), and surface stoichiometry was measured using scanning electron microscopy – energy dispersive X-ray spectroscopy (SEM-EDS). Results indicate that sonicating the arsenopyrite particles and then cleaning them with 12N HCl followed by 50% ethanol, and drying in nitrogen was the most effective method. This method was successful in greatly reducing the oxide species of Fe while completely removing oxides of As and S from the arsenopyrite surface. Although sonication and acid cleaning have been widely used for mineral preparation, the method described in this study can significantly reduce grain size heterogeneity as well as surface oxidation, which enables greater control in surface and dissolution experiments.« less

  11. A method for preparation and cleaning of uniformly sized arsenopyrite particles

    DOE PAGES

    Parthasarathy, Hariprasad; Baltrus, John P; Dzombak, David A; ...

    2014-10-11

    The oxidative dissolution of sulfide minerals, such as arsenopyrite (FeAsS), is of critical importance in many geochemical systems. A comprehensive understanding of their dissolution rates entails careful preparation of the mineral surface. Measurements of dissolution rates of arsenic from arsenopyrite are dependent on the size and degree of oxidation of its particles, among other factors. In this work, a method was developed for preparation and cleaning of arsenopyrite particles with size range of 150–250 μm. Four different cleaning methods were evaluated for effectiveness based on the removal of oxidized species of iron (Fe), arsenic (As) and sulfur (S) from themore » surface. The percentage oxidation of the surface was determined using X-ray photoelectron spectroscopy (XPS), and surface stoichiometry was measured using scanning electron microscopy – energy dispersive X-ray spectroscopy (SEM-EDS). Results indicate that sonicating the arsenopyrite particles and then cleaning them with 12N HCl followed by 50% ethanol, and drying in nitrogen was the most effective method. This method was successful in greatly reducing the oxide species of Fe while completely removing oxides of As and S from the arsenopyrite surface. Although sonication and acid cleaning have been widely used for mineral preparation, the method described in this study can significantly reduce grain size heterogeneity as well as surface oxidation, which enables greater control in surface and dissolution experiments.« less

  12. [Breeding and management of mycobacteria-free guinea pigs (author's transl)].

    PubMed

    Kazda, J

    1976-08-01

    A number of mycobacterial species are detectable under conventional holding condition of guinea pigs. These mycobacteria originating in drinking water and litter caused cross reactions in the Jones-Mote hypersensitivity test. Using suitable precautions it was possible to breed and hold the animals mycobacteria-free. The precautions depend mainly in alteration of the wire mesh floor in cages to avoide the contact of the animals with the litter, in cleaning and desinfection of water bottles, in using of heated water and food and in the prevention of mycobacterial contamination from the staff. The control examination on mycobacteria without treating is given in details. Cases are refered in which a oral rece ption of mycobacteria can alter the immune response. The modification of guinea pigs management to the mycobacteria-free ones is possible in a short time and with minimal cost.

  13. Chapter 4: Assessing the Air Pollution, Greenhouse Gas, Air Quality, and Health Benefits of Clean Energy Initiatives

    EPA Pesticide Factsheets

    Chapter 4 of Assessing the Multiple Benefits of Clean Energy helps state states understand the methods, models, opportunities, and issues associated with assessing the GHG, air pollution, air quality, and human health benefits of clean energy options.

  14. 40 CFR 60.2972 - How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.2972 Section 60.2972... Only Wood Waste, Clean Lumber, and Yard Waste § 60.2972 How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a) Use Method 9 of appendix A of this...

  15. 40 CFR 60.2972 - How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.2972 Section 60.2972... Only Wood Waste, Clean Lumber, and Yard Waste § 60.2972 How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a) Use Method 9 of appendix A of this...

  16. Revised methods for estimating potential reentry exposure associated with indoor crack and crevice and perimeter application.

    PubMed

    Driver, Jeffrey H; Ross, John H; Pandian, Muhilan; Selim, Sami; Sharp, Janice K

    2013-01-01

    Surface deposition of insecticides applied as indoor residential foggers, baseboard or perimeter sprays, spot sprays, and crack-and-crevice (C&C) sprays represent pathways of unintentional, postapplication exposure for children and adults. Estimation of the magnitude of this exposure following an application event is associated with uncertainty due to many factors, including (1) surface residue deposition and distribution, (2) access to and the nature of contact with treated surfaces based on time-activity patterns of residents, and (3) the role of residue removal mechanisms such as cleaning treated surfaces, pesticide degradation or redistribution, and hand washing and bathing following contact. A comparative spatial deposition study was conducted involving broadcast, perimeter, and C&C application methods. Residues measured using a spatial grid of deposition dosimeters on floor surfaces demonstrated significantly lower residue concentrations in readily accessible areas following C&C and perimeter applications, versus broadcast treatment. Analyses of other monitoring studies support this finding. The implications of these findings are discussed for both screening-level and higher tier probabilistic postapplication, residential exposure assessment. The U.S. Environmental Protection Agency (EPA) current guidance on interpretation of deposition following C&C application is supported by data in this study and others that indicate a ratio of 10:1 for deposition for broadcast versus C&C application. However, the perimeter deposition data are quite similar to C&C deposition and do not support a 70/30 default relative to broadcast recommended by the U.S. EPA (2012).

  17. Intestinal helminths in Luweero district, Uganda.

    PubMed

    Dumba, Robinah; Kaddu, John B; Wabwire Mangen, Fred

    2008-06-01

    Intestinal helminthiasis is a debilitating parasitic disease found in many parts of Uganda including Luweero district. In the district, the disease causes as high as 9% morbidity in children below five years. There was very scanty district information on the disease based mainly on hospital records despite this figure. The current study was carried out to provide data to plan for its effective control. To investigate risk factors that promote helminth infections among children under five years of age in Luweero district. Stool samples from 727 children were examined for presence of helminth ova using Kato-Katz technique. The subjects' parents or guardians were interviewed using a semi-structured questionnaire to establish their demographic, social-cultural characteristics; information on water accessibility and usage; child toileting practices and knowledge about helminthiasis. Risk factors strongly associated with helminth infections included methods of anal cleaning, how compounds and latrines were maintained, keeping of pigs and age of the subjects, (P <0.001). In addition, methods of hand washing after latrine visits, the respondents' education level, type of house floor and household compound as well as accessibility to water were associated with worm infection. The hygiene practices of the parents/guardians and environmental surroundings in which the child grows play a big part in determining his or her helminth status. The District Health workers, community leaders and extension staff should educate the community on the importance of personal hygiene and environmental sanitation to minimize the risks of helminth infections.

  18. Gas cleaning system and method

    DOEpatents

    Newby, Richard Allen

    2006-06-06

    A gas cleaning system for removing at least a portion of contaminants, such as halides, sulfur, particulates, mercury, and others, from a synthesis gas (syngas). The gas cleaning system may include one or more filter vessels coupled in series for removing halides, particulates, and sulfur from the syngas. The gas cleaning system may be operated by receiving gas at a first temperature and pressure and dropping the temperature of the syngas as the gas flows through the system. The gas cleaning system may be used for an application requiring clean syngas, such as, but not limited to, fuel cell power generation, IGCC power generation, and chemical synthesis.

  19. Hardened, environmentally disposable composite granules of coal cleaning refuse, coal combustion waste, and other wastes, and method preparing the same

    DOEpatents

    Burnet, George; Gokhale, Ashok J.

    1990-07-10

    A hardened, environmentally inert and disposable composite granule of coal cleaning refuse and coal combustion waste, and method for producing the same, wherein the coal combustion waste is first granulated. The coal cleaning refuse is pulverized into fine particles and is then bound, as an outer layer, to the granulated coal combustion waste granules. This combination is then combusted and sintered. After cooling, the combination results in hardened, environmentally inert and disposable composite granules having cores of coal combustion waste, and outer shells of coal cleaning refuse. The composite particles are durable and extremely resistant to environmental and chemical forces.

  20. Hardened, environmentally disposable composite granules of coal cleaning refuse, coal combustion waste, and other wastes, and method preparing the same

    DOEpatents

    Burnet, G.; Gokhale, A.J.

    1990-07-10

    A hardened, environmentally inert and disposable composite granule of coal cleaning refuse and coal combustion waste and method for producing the same are disclosed, wherein the coal combustion waste is first granulated. The coal cleaning refuse is pulverized into fine particles and is then bound, as an outer layer, to the granulated coal combustion waste granules. This combination is then combusted and sintered. After cooling, the combination results in hardened, environmentally inert and disposable composite granules having cores of coal combustion waste, and outer shells of coal cleaning refuse. The composite particles are durable and extremely resistant to environmental and chemical forces. 3 figs.

  1. Magnetic pulse cleaning of products

    NASA Astrophysics Data System (ADS)

    Smolentsev, V. P.; Safonov, S. V.; Smolentsev, E. V.; Fedonin, O. N.

    2016-04-01

    The article deals with the application of a magnetic impact for inventing new equipment and methods of cleaning cast precision blanks from fragile or granular thickened surface coatings, which are difficult to remove and highly resistant to further mechanical processing. The issues relating to a rational use of the new method for typical products and auxiliary operations have been studied. The calculation and design methods have been elaborated for load-carrying elements of the equipment created. It has been shown, that the application of the magnetic pulse method, combined with a low-frequency vibration process is perspective at enterprises of general and special machine construction, for cleaning lightweight blanks and containers, used for transporting bulk goods.

  2. MRI-based registration of pelvic alignment affected by altered pelvic floor muscle characteristics.

    PubMed

    Bendová, Petra; Růzicka, Pavel; Peterová, Vera; Fricová, Martina; Springrová, Ingrid

    2007-11-01

    Pelvic floor muscles have potential to influence relative pelvic alignment. Side asymmetry in pelvic floor muscle tension is claimed to induce pelvic malalignment. However, its nature and amplitude are not clear. There is a need for non-invasive and reliable assessment method. An intervention experiment of unilateral pelvic floor muscle activation on healthy females was performed using image data for intra-subject comparison of normal and altered configuration of bony pelvis. Sequent magnetic resonance imaging of 14 females in supine position was performed with 1.5 T static body coil in coronal orientation. The intervention, surface functional electrostimulation, was applied to activate pelvic floor muscles on the right side. Spatial coordinates of 23 pelvic landmarks were localized in each subject and registered by specially designed magnetic resonance image data processing tool (MPT2006), where individual error calculation; data registration, analysis and 3D visualization were interfaced. The effect of intervention was large (Cohen's d=1.34). We found significant differences in quantity (P<0.01) and quality (P=0.02) of normal and induced pelvic displacements. After pelvic floor muscle activation on the right side, pelvic structures shifted most frequently to the right side in ventro-caudal direction. The right femoral head, the right innominate and the coccyx showed the largest displacements. The consequences arising from the capacity of pelvic floor muscles to displace pelvic bony structures are important to consider not only in management of malalignment syndrome but also in treatment of incontinence. The study has demonstrated benefits associated with processing of magnetic resonance image data within pelvic region with high localization and registration reliability.

  3. Sellar Floor Reconstruction with the Medpor Implant Versus Autologous Bone After Transnasal Transsphenoidal Surgery: Outcome in 200 Consecutive Patients.

    PubMed

    Liebelt, Brandon D; Huang, Meng; Baskin, David S

    2015-08-01

    The Medpor porous polyethylene implant provides benefits to perform sellar floor reconstruction when indicated. This material has been used for cranioplasty and reconstruction of skull base defects and facial fractures. We present the most extensive use of this implant for sellar floor reconstruction and document the safety and benefits provided by this unique implant. The medical charts for 200 consecutive patients undergoing endonasal transsphenoidal surgery from April 2008 through December 2011 were reviewed. Material used for sellar floor reconstruction, pathologic diagnosis, immediate inpatient complications, and long-term complications were documented and analyzed. Outpatient follow-up was documented for a minimum of 1-year duration, extending in some patients up to 5 years. Of the 200 consecutive patients, 136 received sellar floor cranioplasty using the Medpor implant. Postoperative complications included 6 complaints of sinus irritation or drainage, 1 postoperative cerebrospinal fluid leak requiring operative re-exploration, 1 event of tension pneumocephalus requiring operative decompression, 1 case of aseptic meningitis, 1 subdural hematoma, and 1 case of epistaxis. The incidence of these complications did not differ from the autologous nasal bone group in a statistically significant manner. Sellar floor reconstruction remains an important part of transsphenoidal surgery to prevent postoperative complications. Various autologous and synthetic options are available to reconstruct the sellar floor, and the Medpor implant is a safe and effective option. The complication rate after surgery is equivalent to or less frequent than other methods of reconstruction and the implant is readily incorporated into host tissue after implantation, minimizing infectious risk. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Contributing to the debate on categorising shared sanitation facilities as 'unimproved': An account based on field researchers' observations and householders' opinions in three regions, Tanzania.

    PubMed

    Massa, Khalid; Kilamile, Fadhili; Safari, Emmanuela; Seleman, Amour; Mwakitalima, Anyitike; Balengayabo, Jonas G; Kassile, Telemu; Mangesho, Peter E; Mubyazi, Godfrey M

    2017-01-01

    Health risks associated with poor sanitation behaviours continue to be reported mostly from low-income countries (LICs). Reports show that various factors limit many people from accessing and using improved latrines, forcing some to opt for sharing latrines with neighbours, others practicing open defecation. Meanwhile, debate prevails on whether shared latrines should be categorised as unimproved according to WHO/UNICEF-JMP criteria. We contribute to this debate based on results from a study undertaken in three regions, Tanzania. Data were collected through observations in 1,751 households with latrines, coupled with collection of opinions from heads of such households regarding the latrine-sharing practices. Bivariate and multivariate logistic regression analyses were performed to assess associations between the outcome and possible predictor variables. Of all 1,751 latrines, 14.6% were shared. Among the shared latrines, 74.2% were found being generally clean as compared to 69.2% of the non-shared ones. Comparing the shared and non-shared latrines, the non-shared latrines were significantly less likely to be found with floors built with permanent materials (OR = 0.73, 95% CI: 0.55, 0.98); washable floors (OR = 0.69; 95% CI: 0.51, 0.93); and lockable doors (OR = 0.73; 95% CI: 0.56, 0.95). Shared latrines were less likely to have floors with faecal matter, functional handwashing facilities (HWFs), HWFs with running water, and roofs; albeit the differences in all these scenarios were not statistically significant. Respondents expressed desire for improved latrines, but also did not find it wrong to share latrines if cleanliness was maintained. Having an 'improved' latrine remains important as JMP recommends, but based on our study findings, we argue that possessing a non-shared latrine neither guarantees safety to its users nor its categorisation as 'improved'. Instead, the state of the latrine, the construction technology used and the behaviours of the users may be more important.

  5. Microwave heating apparatus and method

    DOEpatents

    Johnson, Andrew J.; Petersen, Robert D.; Swanson, Stephen D.

    1990-01-01

    An apparatus is provided for heating and melting materials using microwave energy, and for permitting them to solidify. The apparatus includes a microwave energy source, a resonant cavity having an opening in its floor, a microwave energy choke encompassing the opening in the floor of the cavity, a metal container to hold the materials to be heated and melted, a turntable, and a lift-table. During operation, the combined action of the turntable and the lift-table position the metal container so that the top of the container is level with the floor of the cavity, is in substantial registration with the floor opening, and is encompassed by the microwave energy choke; thus, during operation, the interior of the container defines part of the resonant cavity. Additionally, a screw feeder, extending into the cavity and sheltered from microwave energy by a conveyor choke, may convey the materials to be heated to the container. Also, preferably, the floor of the resonant cavity may include perforatins, so that the offgases and dust generated in the apparatus may be removed from the resonant cavity by pulling outside air between the container choke and the exterior wall of the container into the resonant cavity and out from the cavity through the perforations.

  6. Laser cleaning of the contaminations on the surface of tire mould

    NASA Astrophysics Data System (ADS)

    Ye, Yayun; Jia, Baoshen; Chen, Jing; Jiang, Yilan; Tang, Hongping; Wang, Haijun; Luan, Xiaoyu; Liao, Wei; Zhang, Chuanchao; Yao, Caizhen

    2017-07-01

    During the manufacturing of tires, surface pollutants on tire mould will lead to the production of unqualified tires. Tire moulds need to be regularly cleaned. Laser cleaning is recognized as a non-destructive, effective, precise and environmental friendly method. In this paper, laser cleaning was used to remove contaminants on tire mould surface. First, laser induced damage experiments were performed. The results showed that the roughness and hardness of the cast steel sample surface seldom changed under the energy range of 140.1-580.2 mJ laser irradiation 1 pulse and the energy range of 44.7-168.9 mJ laser irradiation 100 pulses. In the laser cleaning experiments, the cleaning thresholds and the optimal cleaning parameters were obtained. Results indicated that laser cleaning was safe and effective for tire mould contamination removal.

  7. Root canal preparation in endodontics: conventional versus laser methods

    NASA Astrophysics Data System (ADS)

    Goodis, Harold E.; White, Joel M.; Marshall, Sally J.; Marshall, Grayson W.; Moskowitz, Emrey

    1992-06-01

    Conventional cleaning and shaping of root canal systems employs hand and/or rotary instrumentation to remove the contents of the canal and shape the canal to receive a filling material. With the advent of the Nd:YAG laser system another method of accomplishing proper cleaning and shaping is evaluated. Single rooted teeth were radiographed bucco- lingually and mesio-distally and were divided into 2 groups. The first group was accessed and the root canal systems cleaned and shaped with a step back technique utilizing hand files and gates glidden burs. At completion of the procedure the teeth were again radiographed at the same positions as those prior to the procedure. The teeth were split longitudinally and examined under scanning electron microscopy to assess cleaning. The second group of teeth were accessed, and cleaning and shaping was accomplished using the Nd:YAG laser in combination with hand files and rotary instruments. These teeth were subjected to the same analysis as those in the first group. The before and after radiographs of each group were subjected to image analysis to determine effectiveness of the two methods in shaping the canal systems. We will discuss the ability of Nd:YAG to clean and shape root canal spaces and remove smear layer and organic tissue remnants from those areas.

  8. Cleaning High-Voltage Equipment With Corncob Grit

    NASA Technical Reports Server (NTRS)

    Caveness, C.

    1986-01-01

    High electrical resistance of particles makes power shutdown unnecessary. New, inexpensive method of cleaning high-voltage electrical equipment uses plentiful agricultural product - corncob grit. Method removes dirt and debris from transformers, circuit breakers, and similar equipment. Suitable for utilities, large utility customers, and electrical-maintenance services.

  9. Wiltech Component Cleaning and Refurbishment Facility CFC Elimination Plan at NASA Kennedy Space Center

    NASA Technical Reports Server (NTRS)

    Williamson, Steve; Aman, Bob; Aurigema, Andrew; Melendez, Orlando

    1999-01-01

    The Wiltech Component Cleaning & Refurbishment Facility (WT-CCRF) at NASA Kennedy Space Center performs precision cleaning on approximately 200,000 metallic and non metallic components every year. WT-CCRF has developed a CFC elimination plan consisting of aqueous cleaning and verification and an economical dual solvent strategy for alternative solvent solution. Aqueous Verification Methodologies were implemented two years ago on a variety of Ground Support Equipment (GSE) components and sampling equipment. Today, 50% of the current workload is verified using aqueous methods and 90% of the total workload is degreased aqueously using, Zonyl and Brulin surfactants in ultrasonic baths. An additional estimated 20% solvent savings could be achieved if the proposed expanded use of aqueous methods are approved. Aqueous cleaning has shown to be effective, environmentally friendly and economical (i.e.. cost of materials, equipment, facilities and labor).

  10. Coal-cleaning plant refuse characterization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cavalet, J.R.; Torak, E.R.

    1985-06-01

    This report describes a study performed for the Electric Power Research Institute's Coal Cleaning Test Facility in Homer City, Pennsylvania. The purpose of the study was to design a standard methods for chemically and physically classifying refuse generated by physical coal cleaning and to construct a matrix that will accurately predict how a particular refuse will react to particular disposal methods - based solely on raw-coal characteristics and the process used to clean the coal. The value of such a classification system (which has not existed to this point) is the ability to design efficient and economical systems for disposingmore » of specific coal cleaning refuse. The report describes the project's literature search and a four-tier classification system. It also provides designs for test piles, sampling procedures, and guidelines for a series of experiments to test the classfication system and create an accurate, reliable predictive matrix. 38 refs., 39 figs., 35 tabs.« less

  11. Method and apparatus for a self-cleaning filter

    DOEpatents

    Diebold, James P.; Lilley, Arthur; Browne, III, Kingsbury; Walt, Robb Ray; Duncan, Dustin; Walker, Michael; Steele, John; Fields, Michael

    2013-09-10

    A method and apparatus for removing fine particulate matter from a fluid stream without interrupting the overall process or flow. The flowing fluid inflates and expands the flexible filter, and particulate is deposited on the filter media while clean fluid is permitted to pass through the filter. This filter is cleaned when the fluid flow is stopped, the filter collapses, and a force is applied to distort the flexible filter media to dislodge the built-up filter cake. The dislodged filter cake falls to a location that allows undisrupted flow of the fluid after flow is restored. The shed particulate is removed to a bin for periodic collection. A plurality of filter cells can operate independently or in concert, in parallel, or in series to permit cleaning the filters without shutting off the overall fluid flow. The self-cleaning filter is low cost, has low power consumption, and exhibits low differential pressures.

  12. Method and apparatus for a self-cleaning filter

    DOEpatents

    Diebold, James P.; Lilley, Arthur; Browne, III, Kingsbury; Walt, Robb Ray; Duncan, Dustin; Walker, Michael; Steele, John; Fields, Michael

    2010-11-16

    A method and apparatus for removing fine particulate matter from a fluid stream without interrupting the overall process or flow. The flowing fluid inflates and expands the flexible filter, and particulate is deposited on the filter media while clean fluid is permitted to pass through the filter. This filter is cleaned when the fluid flow is stopped, the filter collapses, and a force is applied to distort the flexible filter media to dislodge the built-up filter cake. The dislodged filter cake falls to a location that allows undisrupted flow of the fluid after flow is restored. The shed particulate is removed to a bin for periodic collection. A plurality of filter cells can operate independently or in concert, in parallel, or in series to permit cleaning the filters without shutting off the overall fluid flow. The self-cleaning filter is low cost, has low power consumption, and exhibits low differential pressures.

  13. Environmental monitoring of the orbiter payload bay and Orbiter Processing Facilities

    NASA Technical Reports Server (NTRS)

    Bartelson, D. W.; Johnson, A. M.

    1985-01-01

    Contamination control in the Orbiter Processing Facility (OPF) is studied. The clean level required in the OPF is generally clean, which means no residue, dirt, debris, or other extraneous contamination; various methods of maintaining this level of cleanliness are described. The monitoring and controlling of the temperature, relative humidity, and air quality in the OPF are examined. Additional modifications to the OPF to improve contamination control are discussed. The methods used to maintain the payload changeout room at a level of visually clean, no particulates are to be detected by the unaided eye, are described. The payload bay (PLB) must sustain the cleanliness level required for the specific Orbiter's mission; the three levels of clean are defined as: (1) standard, (2) sensitive, and (3) high sensitive. The cleaning and inspection verification required to achieve the desired cleanliness level on a variety of PLB surface types are examined.

  14. Cleaning Aged EPDM Rubber Roofing Membrane Material for Patching: Laboratory Investigations and Recommendations

    DTIC Science & Technology

    1992-08-01

    Cleaning Aged EPDM Rubber Roofing Membrane Material for Patching: Laboratory Investigations and Recommendations Walter J. Rossiter, Jr. T N n-’T ic...condition of the aged EPDM rubber before bonding. This study assessed the effectiveness of different cleaning methods for preparing aged EPDM membranes for...REPORT DATE 3. REPORT TYPE AND DATES COVERED August 1992 Final 4. TITLE AND SUBTITLE 5. FUNDING NUMBERS Cleaning Aged EPDM Rubber Roofing Membrane

  15. Comparing visual inspection, aerobic colony counts, and adenosine triphosphate bioluminescence assay for evaluating surface cleanliness at a medical center.

    PubMed

    Huang, Yu-Shan; Chen, Yee-Chun; Chen, Mei-Ling; Cheng, Aristine; Hung, I-Chen; Wang, Jann-Tay; Sheng, Wang-Huei; Chang, Shan-Chwen

    2015-08-01

    Environmental cleaning is essential in reducing microbial colonization and health care-associated infections in hospitals. However, there is no consensus for the standard method to assess hospital cleanliness, and comparisons of newer methodology, such as adenosine triphosphate bioluminescence assay, with the traditional methods are limited. A prospective study was conducted at a medical center between January 2013 and August 2013. In each selected room, 10-12 high-touch surfaces were sampled before and after terminal cleaning. The adequacy of cleaning was evaluated by visual inspection, aerobic colony counts (ACCs), and adenosine triphosphate (ATP) bioluminescence assay. Eighty-five environmental surfaces from 8 rooms were evaluated by all 3 methods. The overall inadequacy defined by visual inspection, ACC, and ATP level was 11.8%, 20.0%, and 50.6% before cleaning and 4.7%, 5.9%, 21.2% after cleaning, respectively. A correlation between the ACC and ATP was found (r = 0.285, P < .001) using log10 values. Using ACCs <2.5 colony forming units/cm(2) as the cutoff for cleanliness, the ATP assay had better sensitivity than visual inspection (63.6% vs 27.3%). The receiver operating characteristics of the ATP assay indicated that the optimal ATP cutoff value was estimated to be 5.57 relative light units/cm(2). ATP bioluminescence assay is a sensitive and rapid tool in evaluating the quality of terminal cleaning. We emphasize the value of using a quantitative method to monitor environmental cleaning at hospitals. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  16. Comparing the field and laboratory emission cell (FLEC) with traditional emissions testing chambers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roache, N.F.; Guo, Z.; Fortmann, R.

    1996-12-31

    A series of tests was designed to evaluate the performance of the field and laboratory emission cell (FLEC) as applied to the testing of emissions from two indoor coating materials, floor wax and latex paint. These tests included validation of the repeatability of the test method, evaluation of the effect of different air velocities on source emissions, and a comparison of FLEC versus small chamber characterization of emissions. The FLEC exhibited good repeatability in characterization of emissions when applied to both sources under identical conditions. Tests with different air velocities showed significant effects on the emissions from latex paint, yetmore » little effect on emissions from the floor wax. Comparisons of data from the FLEC and small chamber show good correlation for measurements involving floor wax, but less favorable results for emissions from latex paint. The procedures and findings are discussed; conclusions are limited and include emphasis on the need for additional study and development of a standard method.« less

  17. Challenging Residual Contamination of Instruments for Robotic Surgery in Japan.

    PubMed

    Saito, Yuhei; Yasuhara, Hiroshi; Murakoshi, Satoshi; Komatsu, Takami; Fukatsu, Kazuhiko; Uetera, Yushi

    2017-02-01

    BACKGROUND Recently, robotic surgery has been introduced in many hospitals. The structure of robotic instruments is so complex that updating their cleaning methods is a challenge for healthcare professionals. However, there is limited information on the effectiveness of cleaning for instruments for robotic surgery. OBJECTIVE To determine the level of residual contamination of instruments for robotic surgery and to develop a method to evaluate the cleaning efficacy for complex surgical devices. METHODS Surgical instruments were collected immediately after operations and/or after in-house cleaning, and the level of residual protein was measured. Three serial measurements were performed on instruments after cleaning to determine the changes in the level of contamination and the total amount of residual protein. The study took place from September 1, 2013, through June 30, 2015, in Japan. RESULTS The amount of protein released from robotic instruments declined exponentially. The amount after in-house cleaning was 650, 550, and 530 µg/instrument in the 3 serial measurements. The overall level of residual protein in each measurement was much higher for robotic instruments than for ordinary instruments (P<.0001). CONCLUSIONS Our data demonstrated that complete removal of residual protein from surgical instruments is virtually impossible. The pattern of decline differed depending on the instrument type, which reflected the complex structure of the instruments. It might be necessary to establish a new standard for cleaning using a novel classification according to the structural complexity of instruments, especially for those for robotic surgery. Infect Control Hosp Epidemiol 2017;38:143-146.

  18. 198: THE EFFECT OF INSTRUCTING PELVIC FLOOR MUSCLE TRAINING FOR CONTROLLING URINARY INCONTINENCE AND ITS RESULTING STRESS, ANXIETY AND DEPRESSION IN PATIENTS WITH MULTIPLE SCLEROSIS

    PubMed Central

    Shareinia, Habib; Rafii, Forough; Sarraf, Payam; Seyedalshohahadaee, Mahnaz

    2017-01-01

    Background and aims Urinary disorders are common problems in patients with multiple sclerosis (MS). Urinary incontinence largely affects the physical, social, and emotional characteristics and activities of these patients. The aim of this study was to identify the effect of pelvic floor muscle Training on urinary incontinence and its resulting stress, anxiety and depression in MS patients. Methods The present clinical trial with a pre-post design was conducted on 50 MS patients presenting to the MS clinic of Imam Khomeini Hospital in Tehran (Iran) who had been selected by convenience sampling method. Participants received instructions on pelvic floor muscle exercises and then practiced them for three consecutive months. The International Consultation on Incontinence Questionnaire – Urinary Incontinence Short Form (ICIQ-UI SF) was used to measure participants' urinary incontinence and the 21-item Depression, Anxiety and Stress Scale (DASS-21) then used to measure their depression, anxiety and stress, both before the intervention and at the end of the third month of exercising. The data obtained were analyzed in SPSS16 using descriptive statistics and the dependent t test. Results About 45 (90%) participants practiced pelvic floor muscle exercises up until the end of the third month. The frequency and amount of urine leakage and the effect of urinary incontinence on the quality of life differed significantly in the patients after the instructions compared to before (P<0.001). The mean score of stress (P<0.001), anxiety (P=0.04) and depression (P=0.003) decreased significantly after the intervention. Conclusion According to the findings, instructing pelvic floor muscle exercises is effective in reducing urinary incontinence and its resulting stress, anxiety and depression in MS patients. These exercises are therefore recommended as a non-pharmacological, non-invasive and cost-effective method for controlling urinary incontinence in MS patients.

  19. A constrained-gradient method to control divergence errors in numerical MHD

    NASA Astrophysics Data System (ADS)

    Hopkins, Philip F.

    2016-10-01

    In numerical magnetohydrodynamics (MHD), a major challenge is maintaining nabla \\cdot {B}=0. Constrained transport (CT) schemes achieve this but have been restricted to specific methods. For more general (meshless, moving-mesh, ALE) methods, `divergence-cleaning' schemes reduce the nabla \\cdot {B} errors; however they can still be significant and can lead to systematic errors which converge away slowly. We propose a new constrained gradient (CG) scheme which augments these with a projection step, and can be applied to any numerical scheme with a reconstruction. This iteratively approximates the least-squares minimizing, globally divergence-free reconstruction of the fluid. Unlike `locally divergence free' methods, this actually minimizes the numerically unstable nabla \\cdot {B} terms, without affecting the convergence order of the method. We implement this in the mesh-free code GIZMO and compare various test problems. Compared to cleaning schemes, our CG method reduces the maximum nabla \\cdot {B} errors by ˜1-3 orders of magnitude (˜2-5 dex below typical errors if no nabla \\cdot {B} cleaning is used). By preventing large nabla \\cdot {B} at discontinuities, this eliminates systematic errors at jumps. Our CG results are comparable to CT methods; for practical purposes, the nabla \\cdot {B} errors are eliminated. The cost is modest, ˜30 per cent of the hydro algorithm, and the CG correction can be implemented in a range of numerical MHD methods. While for many problems, we find Dedner-type cleaning schemes are sufficient for good results, we identify a range of problems where using only Powell or `8-wave' cleaning can produce order-of-magnitude errors.

  20. Dry cleaning of Turkish coal

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cicek, T.

    2008-07-01

    This study dealt with the upgrading of two different type of Turkish coal by a dry cleaning method using a modified air table. The industrial size air table used in this study is a device for removing stones from agricultural products. This study investigates the technical and economical feasibility of the dry cleaning method which has never been applied before on coals in Turkey. The application of a dry cleaning method on Turkish coals designated for power generation without generating environmental pollution and ensuring a stable coal quality are the main objectives of this study. The size fractions of 5-8,more » 3-5, and 1-3 mm of the investigated coals were used in the upgrading experiments. Satisfactory results were achieved with coal from the Soma region, whereas the upgrading results of Hsamlar coal were objectionable for the coarser size fractions. However, acceptable results were obtained for the size fraction 1-3 mm of Hsamlar coal.« less

  1. On-chip purification via liquid immersion of arc-discharge synthesized multiwalled carbon nanotubes

    NASA Astrophysics Data System (ADS)

    Hokkanen, Matti J.; Lautala, Saara; Shao, Dongkai; Turpeinen, Tuomas; Koivistoinen, Juha; Ahlskog, Markus

    2016-07-01

    Arc-discharge synthesized multiwalled carbon nanotubes (AD-MWNT) have been proven to be of high quality, but their use is very limited due to difficulties in obtaining them in a clean and undamaged form. Here, we present a simple method that purifies raw AD-MWNT material in laboratory scale without damage, and that in principle can be scaled up. The method consists of depositing raw AD-MWNT material on a flat substrate and immersing the substrate slowly in water, whereby the surface tension force of the liquid-substrate contact line selectively sweeps away the larger amorphous carbon debris and leaves relatively clean MWNTs on the substrate. We demonstrate the utility of the method by preparing clean individual MWNTs for measurement of their Raman spectra. The spectra exhibit the characteristics of high-quality tubes free from contaminants. We also show how one concomitantly with the purification process can obtain large numbers of clean suspended MWNTs.

  2. Impact of vaginal parity and aging on the architectural design of pelvic floor muscles.

    PubMed

    Alperin, Marianna; Cook, Mark; Tuttle, Lori J; Esparza, Mary C; Lieber, Richard L

    2016-09-01

    Vaginal delivery and aging are key risk factors for pelvic floor muscle dysfunction, which is a critical component of pelvic floor disorders. However, alterations in the pelvic floor muscle intrinsic structure that lead to muscle dysfunction because of childbirth and aging remain elusive. The purpose of this study was to determine the impact of vaginal deliveries and aging on human cadaveric pelvic floor muscle architecture, which is the strongest predictor of active muscle function. Coccygeus, iliococcygeus, and pubovisceralis were obtained from younger donors who were ≤51 years old, vaginally nulliparous (n = 5) and vaginally parous (n = 6) and older donors who were >51 years old, vaginally nulliparous (n = 6) and vaginally parous (n = 6), all of whom had no history of pelvic floor disorders. Architectural parameters, which are predictive of muscle's excursion and force-generating capacity, were determined with the use of validated methods. Intramuscular collagen content was quantified by hydroxyproline assay. Main effects of parity and aging and the interactions were determined with the use of 2-way analysis of variance, with Tukey's post-hoc testing and a significance level of .05. The mean age of younger and older donors differed by approximately 40 years (P = .001) but was similar between nulliparous and parous donors within each age group (P > .9). The median parity was 2 (range, 1-3) in younger and older vaginally parous groups (P = .7). The main impact of parity was increased fiber length in the more proximal coccygeus (P = .03) and iliococcygeus (P = .04). Aging changes manifested as decreased physiologic cross-sectional area across all pelvic floor muscles (P < .05), which substantially exceeded the age-related decline in muscle mass. The physiologic cross-sectional area was lower in younger vaginally parous, compared with younger vaginally nulliparous, pelvic floor muscles; however, the differences did not reach statistical significance. Pelvic floor muscle collagen content was not altered by parity but increased dramatically with aging (P < .05). Increased fiber length in more proximal pelvic floor muscles likely represents an adaptive response to the chronically increased load placed on these muscles by the displaced apical structures, presumably as a consequence of vaginal delivery. In younger specimens, a consistent trend towards decrease in force-generating capacity of all pelvic floor muscles in the parous group suggests a potential mechanism for clinically identified pelvic floor muscle weakness in vaginally parous women. The substantial decrease in predicted muscle force production and fibrosis with aging represent likely mechanisms for the pelvic floor muscle dysfunction in older women. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Self-Cleaning Surfaces: A Third-Year Undergraduate Research Project

    ERIC Educational Resources Information Center

    Haines, Ronald S.; Wu, Alex H. F.; Zhang, Hua; Coffey, Jacob; Huddle, Thomas; Lafountaine, Justin S.; Lim, Zhi-Jun; White, Eugene A.; Tuong, Nam T.; Lamb, Robert N.

    2009-01-01

    Superhydrophobic (non water-wettable) surfaces can possess the ability to self-clean (the so-called "lotus effect"). The task of devising the apparatus and method for quantifying this self-cleaning effect was offered as a project in a third-year undergraduate laboratory course. Using commonly available equipment the students devised a…

  4. 9 CFR 3.11 - Cleaning, sanitization, housekeeping, and pest control.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ..., Treatment, and Transportation of Dogs and Cats 1 Animal Health and Husbandry Standards § 3.11 Cleaning... prevent an excessive accumulation of feces and food waste, to prevent soiling of the dogs or cats... water is used to clean the primary enclosure, whether by hosing, flushing, or other methods, dogs and...

  5. 9 CFR 3.11 - Cleaning, sanitization, housekeeping, and pest control.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ..., Treatment, and Transportation of Dogs and Cats 1 Animal Health and Husbandry Standards § 3.11 Cleaning... prevent an excessive accumulation of feces and food waste, to prevent soiling of the dogs or cats... water is used to clean the primary enclosure, whether by hosing, flushing, or other methods, dogs and...

  6. Practical Approaches for Assessment of Daily and Post-discharge Room Disinfection in Healthcare Facilities.

    PubMed

    Deshpande, Abhishek; Donskey, Curtis J

    2017-09-01

    Cleaning and disinfection in healthcare facilities is essential to ensure patient safety. This review examines practical strategies used to assess and improve the effectiveness of daily and post-discharge manual cleaning in healthcare facilities. Effective implementation of cleaning interventions requires objective monitoring of staff performance with regular feedback on performance. Use of fluorescent markers to assess thoroughness of cleaning and measurement of residual ATP can provide rapid and objective feedback to personnel and have been associated with improved cleaning. Direct observation of cleaning and interviews with front-line staff are useful to identify variations and deficiencies in practice that may not be detected by other methods. Although not recommended for routine monitoring, cultures can be helpful for outbreak investigations. Monitoring and feedback can be effective in improving cleaning and disinfection in healthcare facilities. Ongoing commitment within institutions is needed to sustain successful cleaning and disinfection programs.

  7. An evaluation of alternative cleaning methods for removing an organic contaminant from a stainless steel part

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boyd, J.L.

    1996-08-01

    As of December 1995, the manufacture of Freon, along with many other chlorofluorocarbons (CFCs), was prohibited by the Clean Air Act of 1990 (CAA). The ban of CFC solvents has forced manufacturers across the country to search for alternative metal cleaning techniques. The objective of this study was to develop a thorough, scientific based approach for resolving one specific manufacturer`s problem of removing organic contamination from a stainless steel part. This objective was accomplished with an approach that involved: (1) defining the problem, (2) identifying the process constraints, (3) researching alternate cleaning methods, (4) researching applicable government regulations, (5) performingmore » a scientific evaluation and (6) drawing conclusions.« less

  8. Evaluation of four sampling methods for determining exposure of children to lead-contaminated household dust

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sterling, D.A.; Roegner, K.C.; Lewis, R.D.

    Childhood exposure to lead has been demonstrated to result in health effects and lead-contaminated household dust is a primary exposure source. There is a need to establish reliable methods for sampling surfaces to determine levels of lead contamination. Three vacuums (HVS3, GS80, and MVM) and one wipe method were evaluated for the collection of household floor dust under field sampling conditions within a Superfund site and demographically similar control area. Side-by-side floor samples were taken from three locations within 41 randomly selected households between August and September 1995: a child's bedroom, primary play area, and primary entrance. Analysis was performedmore » to assess the relative collection performance of each sampler, spatial distribution of lead within a household, and correlation of lead loading with observed blood lead level, and to determine if discrete or composites samples were more predictive of blood lead levels. Approximately 90% of the floor surfaces were carpeted. The rank order of sampling methods from greatest to lowest collection efficiency was HVS3 > G80 > wipe > MVM. The HVS3 had the highest level of precision (CV = 0.05), with the GS80 and wipe precisions 0.48 and 0.053, respectively.« less

  9. Automatic segmentation method of pelvic floor levator hiatus in ultrasound using a self-normalizing neural network

    PubMed Central

    Dietz, Hans Peter; D’hooge, Jan; Barratt, Dean; Deprest, Jan

    2018-01-01

    Abstract. Segmentation of the levator hiatus in ultrasound allows the extraction of biometrics, which are of importance for pelvic floor disorder assessment. We present a fully automatic method using a convolutional neural network (CNN) to outline the levator hiatus in a two-dimensional image extracted from a three-dimensional ultrasound volume. In particular, our method uses a recently developed scaled exponential linear unit (SELU) as a nonlinear self-normalizing activation function, which for the first time has been applied in medical imaging with CNN. SELU has important advantages such as being parameter-free and mini-batch independent, which may help to overcome memory constraints during training. A dataset with 91 images from 35 patients during Valsalva, contraction, and rest, all labeled by three operators, is used for training and evaluation in a leave-one-patient-out cross validation. Results show a median Dice similarity coefficient of 0.90 with an interquartile range of 0.08, with equivalent performance to the three operators (with a Williams’ index of 1.03), and outperforming a U-Net architecture without the need for batch normalization. We conclude that the proposed fully automatic method achieved equivalent accuracy in segmenting the pelvic floor levator hiatus compared to a previous semiautomatic approach. PMID:29340289

  10. Automatic segmentation method of pelvic floor levator hiatus in ultrasound using a self-normalizing neural network.

    PubMed

    Bonmati, Ester; Hu, Yipeng; Sindhwani, Nikhil; Dietz, Hans Peter; D'hooge, Jan; Barratt, Dean; Deprest, Jan; Vercauteren, Tom

    2018-04-01

    Segmentation of the levator hiatus in ultrasound allows the extraction of biometrics, which are of importance for pelvic floor disorder assessment. We present a fully automatic method using a convolutional neural network (CNN) to outline the levator hiatus in a two-dimensional image extracted from a three-dimensional ultrasound volume. In particular, our method uses a recently developed scaled exponential linear unit (SELU) as a nonlinear self-normalizing activation function, which for the first time has been applied in medical imaging with CNN. SELU has important advantages such as being parameter-free and mini-batch independent, which may help to overcome memory constraints during training. A dataset with 91 images from 35 patients during Valsalva, contraction, and rest, all labeled by three operators, is used for training and evaluation in a leave-one-patient-out cross validation. Results show a median Dice similarity coefficient of 0.90 with an interquartile range of 0.08, with equivalent performance to the three operators (with a Williams' index of 1.03), and outperforming a U-Net architecture without the need for batch normalization. We conclude that the proposed fully automatic method achieved equivalent accuracy in segmenting the pelvic floor levator hiatus compared to a previous semiautomatic approach.

  11. Use of a fluorescent chemical as a quality indicator for a hospital cleaning program.

    PubMed

    Blue, Jennifer; O'Neill, Cindy; Speziale, Paul; Revill, Jeff; Ramage, Lee; Ballantyne, Lisa

    2008-01-01

    Hamilton Health Sciences is a large teaching hospital with over 1,000 beds and consists of three acute care sites, one Regional Cancer Center and two Rehabilitation/Chronic Care facilities. An environmental cleaning pilot project was initiated at the acute care Henderson site, following an outbreak of vancomycin-resistant Enterococcus (VRE). Healthcare-associated infections (HAI) due to antibiotic-resistant organisms are increasing in Southern Ontario. Environmental cleaning plays a key role in eradicating resistant organisms that live in hospital environments, thereby helping to reduce HAIs. The environmental cleaning practices on the Orthopaedic Unit were identified as a contributing factor to the VRE outbreak after visual assessments were completed using a Brevis GlitterBug product, a chemical that fluoresces under an ultraviolet (UV) lamp. These findings led to a hospital-wide cleaning improvement initiative on all units except critical care areas. The GlitterBug potion was employed by Infection Control and Customer Support Services (CSS) as a tool to evaluate the daily cleaning of patient washrooms as well as discharge cleaning of contact precaution isolation rooms. Over a four-week period, the GlitterBug potion was applied to seven frequently touched standard targets in randomly selected patient bathrooms on each unit and 14 frequently touched targets prior to cleaning in the rooms used for isolation. The targets were then evaluated using the UV lamp to detect objects that were not cleaned and the results were recorded on a standardized form. The rate of targets cleaned versus the targets missed was calculated. The overall rate for daily cleaning of bathrooms and cleaning of isolation rooms was poor with only 23% of the targets cleaned. Based on these findings, several interventions were implemented. This resulted in a significant improvement in cleaning practices during the pilot project. Greater than 80% of the targets were cleaned compared to the baseline findings of 23%. Subsequently, nosocomial cases of VRE have declined despite the increased prevalence of VRE in the Hamilton and surrounding regions. The GlitterBug product is an effective tool to evaluate environmental cleaning and adherence to policies and procedures and this method was superior to previous visual inspection methods. The use of GlitterBug potion improved physical cleaning and enhanced staff contribution. The Brevis GlitterBug product was incorporated into the CSS environmental cleaning program at Hamilton Health Sciences as a quality indicator to monitor environmental cleaning practices.

  12. Apparatus and method for in-situ cleaning of resist outgassing windows

    DOEpatents

    Klebanoff, Leonard E.; Haney, Steven J.

    2001-01-01

    An apparatus and method for in-situ cleaning of resist outgassing windows. The apparatus includes a chamber located in a structure, with the chamber having an outgassing window to be cleaned positioned in alignment with a slot in the chamber, whereby radiation energy passes through the window, the chamber, and the slot onto a resist-coated wafer mounted in the structure. The chamber is connected to a gas supply and the structure is connected to a vacuum pump. Within the chamber are two cylindrical sector electrodes and a filament is electrically connected to one sector electrode and a power supply. In a first cleaning method the sector electrodes are maintained at the same voltage, the filament is unheated, the chamber is filled with argon (Ar) gas under pressure, and the window is maintained at a zero voltage, whereby Ar ions are accelerated onto the window surface, sputtering away carbon deposits that build up as a result of resist outgassing. A second cleaning method is similar except oxygen gas (O.sub.2) is admitted to the chamber instead of Ar. These two methods can be carried out during lithographic operation. A third method, carried out during a maintenance period, involves admitting CO.sub.2 into the chamber, heating the filament to a point of thermionic emission, the sector electrodes are at different voltages, excited CO.sub.2 gas molecules are created which impact the carbon contamination on the window, and gasify it, producing CO gaseous products that are pumped away.

  13. Low extractable wipers for cleaning space flight hardware

    NASA Technical Reports Server (NTRS)

    Tijerina, Veronica; Gross, Frederick C.

    1986-01-01

    There is a need for low extractable wipers for solvent cleaning of space flight hardware. Soxhlet extraction is the method utilized today by most NASA subcontractors, but there may be alternate methods to achieve the same results. The need for low non-volatile residue materials, the history of soxhlet extraction, and proposed alternate methods are discussed, as well as different types of wipers, test methods, and current standards.

  14. Methods/Labor Standards Application Program - Phase IV

    DTIC Science & Technology

    1985-01-01

    Engine Platform a. Pressure switch b. Compressor motor c. Voltage regulator d. Open and clean generator exciter and main windings S3 . Main Collector...clean motors b. Slip rings Gantry #3 Annual: S2. Engine Platform a. Pressure switch b. Compressor motor Voltage regulator d. Open and clean generator...Travel Motors Open and clean motorsa. b. Slip rings Gantry #4 S2 . S3. S4 . S5 . Engine Platform a. Pressure switch b. Compressor motor Voltage regulator

  15. Pulse cleaning flow models and numerical computation of candle ceramic filters.

    PubMed

    Tian, Gui-shan; Ma, Zhen-ji; Zhang, Xin-yi; Xu, Ting-xiang

    2002-04-01

    Analytical and numerical computed models are developed for reverse pulse cleaning system of candle ceramic filters. A standard turbulent model is demonstrated suitably to the designing computation of reverse pulse cleaning system from the experimental and one-dimensional computational result. The computed results can be used to guide the designing of reverse pulse cleaning system, which is optimum Venturi geometry. From the computed results, the general conclusions and the designing methods are obtained.

  16. Measuring the effect of enhanced cleaning in a UK hospital: a prospective cross-over study

    PubMed Central

    Dancer, Stephanie J; White, Liza F; Lamb, Jim; Girvan, E Kirsty; Robertson, Chris

    2009-01-01

    Background Increasing hospital-acquired infections have generated much attention over the last decade. There is evidence that hygienic cleaning has a role in the control of hospital-acquired infections. This study aimed to evaluate the potential impact of one additional cleaner by using microbiological standards based on aerobic colony counts and the presence of Staphylococcus aureus including meticillin-resistant S. aureus. Methods We introduced an additional cleaner into two matched wards from Monday to Friday, with each ward receiving enhanced cleaning for six months in a cross-over design. Ten hand-touch sites on both wards were screened weekly using standardised methods and patients were monitored for meticillin-resistant S. aureus infection throughout the year-long study. Patient and environmental meticillin-resistant S. aureus isolates were characterised using molecular methods in order to investigate temporal and clonal relationships. Results Enhanced cleaning was associated with a 32.5% reduction in levels of microbial contamination at hand-touch sites when wards received enhanced cleaning (P < 0.0001: 95% CI 20.2%, 42.9%). Near-patient sites (lockers, overbed tables and beds) were more frequently contaminated with meticillin-resistant S. aureus/S. aureus than sites further from the patient (P = 0.065). Genotyping identified indistinguishable strains from both hand-touch sites and patients. There was a 26.6% reduction in new meticillin-resistant S. aureus infections on the wards receiving extra cleaning, despite higher meticillin-resistant S. aureus patient-days and bed occupancy rates during enhanced cleaning periods (P = 0.032: 95% CI 7.7%, 92.3%). Adjusting for meticillin-resistant S. aureus patient-days and based upon nine new meticillin-resistant S. aureus infections seen during routine cleaning, we expected 13 new infections during enhanced cleaning periods rather than the four that actually occurred. Clusters of new meticillin-resistant S. aureus infections were identified 2 to 4 weeks after the cleaner left both wards. Enhanced cleaning saved the hospital £30,000 to £70,000. Conclusion Introducing one extra cleaner produced a measurable effect on the clinical environment, with apparent benefit to patients regarding meticillin-resistant S. aureus infection. Molecular epidemiological methods supported the possibility that patients acquired meticillin-resistant S. aureus from environmental sources. These findings suggest that additional research is warranted to further clarify the environmental, clinical and economic impact of enhanced hygienic cleaning as a component in the control of hospital-acquired infection. PMID:19505316

  17. Impact of pH on the stability and the cross-reactivity of ochratoxin A and citrinin.

    PubMed

    Bazin, Ingrid; Faucet-Marquis, Virginie; Monje, Marie-Carmen; El Khoury, Micheline; Marty, Jean-Louis; Pfohl-Leszkowicz, Annie

    2013-11-28

    Mycotoxins are secondary metabolites produced by several fungi contaminating crops. In several countries, the maximum permitted levels of mycotoxins are found in foodstuffs and feedstuffs. The common strategy of mycotoxin analysis involves extraction, clean-up and quantification by chromatography. In this paper, we analyzed the reasons of underestimation of ochratoxin A (OTA) content in wine, and overestimation of OTA in wheat, depending on the pH of the clean-up step and the simultaneous presence of citrinin (CIT). We demonstrated that the increase of pH by adding polyethylene glycol (PEG) to wine led to an underestimation of OTA by conversion of OTA into open ring ochratoxin A OP-OA. In comparing three methods of extraction and clean-up for the determination of OTA and CIT in wheat--(i) an inter-laboratory validated method for OTA in cereals using immunoaffinity column clean-up (IAC) and extraction by acetonitrile/water; (ii) a validated method using IAC and extraction with 1% bicarbonate Na; and (iii) an in-house validated method based on acid liquid/liquid extraction--we observed an overestimation of OTA after immunoaffinity clean-up when CIT is also present in the sample, whereas an underestimation was observed when OTA was alone. Under neutral and alkaline conditions, CIT was partially recognized by OTA antibodies.

  18. Impact of pH on the Stability and the Cross-Reactivity of Ochratoxin A and Citrinin

    PubMed Central

    Bazin, Ingrid; Faucet-Marquis, Virginie; Monje, Marie-Carmen; El Khoury, Micheline; Marty, Jean-Louis; Pfohl-Leszkowicz, Annie

    2013-01-01

    Mycotoxins are secondary metabolites produced by several fungi contaminating crops. In several countries, the maximum permitted levels of mycotoxins are found in foodstuffs and feedstuffs. The common strategy of mycotoxin analysis involves extraction, clean-up and quantification by chromatography. In this paper, we analyzed the reasons of underestimation of ochratoxin A (OTA) content in wine, and overestimation of OTA in wheat, depending on the pH of the clean-up step and the simultaneous presence of citrinin (CIT). We demonstrated that the increase of pH by adding polyethylene glycol (PEG) to wine led to an underestimation of OTA by conversion of OTA into open ring ochratoxin A OP-OA. In comparing three methods of extraction and clean-up for the determination of OTA and CIT in wheat—(i) an inter-laboratory validated method for OTA in cereals using immunoaffinity column clean-up (IAC) and extraction by acetonitrile/water; (ii) a validated method using IAC and extraction with 1% bicarbonate Na; and (iii) an in-house validated method based on acid liquid/liquid extraction—we observed an overestimation of OTA after immunoaffinity clean-up when CIT is also present in the sample, whereas an underestimation was observed when OTA was alone. Under neutral and alkaline conditions, CIT was partially recognized by OTA antibodies. PMID:24287570

  19. Assessment of test methods for evaluating effectiveness of cleaning flexible endoscopes.

    PubMed

    Washburn, Rebecca E; Pietsch, Jennifer J

    2018-06-01

    Strict adherence to each step of reprocessing is imperative to removing potentially infectious agents. Multiple methods for verifying proper reprocessing exist; however, each presents challenges and limitations, and best practice within the industry has not been established. Our goal was to evaluate endoscope cleaning verification tests with particular interest in the evaluation of the manual cleaning step. The results of the cleaning verification tests were compared with microbial culturing to see if a positive cleaning verification test would be predictive of microbial growth. This study was conducted at 2 high-volume endoscopy units within a multisite health care system. Each of the 90 endoscopes were tested for adenosine triphosphate, protein, microbial growth via agar plate, and rapid gram-negative culture via assay. The endoscopes were tested in 3 locations: the instrument channel, control knob, and elevator mechanism. This analysis showed substantial level of agreement between protein detection postmanual cleaning and protein detection post-high-level disinfection at the control head for scopes sampled sequentially. This study suggests that if protein is detected postmanual cleaning, there is a significant likelihood that protein will also be detected post-high-level disinfection. It also infers that a cleaning verification test is not predictive of microbial growth. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  20. Visualization of flow during cleaning process on a liquid nanofibrous filter

    NASA Astrophysics Data System (ADS)

    Bílek, P.

    2017-10-01

    This paper deals with visualization of flow during cleaning process on a nanofibrous filter. Cleaning of a filter is very important part of the filtration process which extends lifetime of the filter and improve filtration properties. Cleaning is carried out on flat-sheet filters, where particles are deposited on the filter surface and form a filtration cake. The cleaning process dislodges the deposited filtration cake, which is loose from the membrane surface to the retentate flow. The blocked pores in the filter are opened again and hydrodynamic properties are restored. The presented optical method enables to see flow behaviour in a thin laser sheet on the inlet side of a tested filter during the cleaning process. The local concentration of solid particles is possible to estimate and achieve new information about the cleaning process. In the article is described the cleaning process on nanofibrous membranes for waste water treatment. The hydrodynamic data were compared to the images of the cleaning process.

Top