Ait Bamai, Yu; Araki, Atsuko; Kawai, Toshio; Tsuboi, Tazuru; Saito, Ikue; Yoshioka, Eiji; Kanazawa, Ayako; Tajima, Shuji; Shi, Cong; Tamakoshi, Akiko; Kishi, Reiko
2014-01-15
Phthalates are widely used as plasticizers in numerous products. However, there has been some concern about the various effects they may have on human health. Thus, household phthalate levels are an important public health issue. While many studies have assessed phthalate levels in house dust, the association of these levels with building characteristics has scarcely been examined. The present study investigated phthalate levels in house dust samples collected from the living areas of homes, and examined associations between these phthalate levels and the interior materials. Dust was collected from two portions of the living area: floor dust from the entire floor surface, and multi-surface dust from objects more than 35 cm above the floor. The levels of seven phthalates were measured using gas chromatography/mass spectrometry in selective ion monitoring mode. Phthalate levels were higher in multi-surface dust than in floor dust. Among floor dust samples, those from dwellings with compressed wooden flooring had significantly higher levels of di-iso-butyl phthalate compared to those with other floor materials, while polyvinyl chloride (PVC) flooring was associated with higher di-2-ethylhexyl phthalate (DEHP) levels. Among multi-surface dust samples, higher levels of DEHP and di-iso-nonyl phthalate (DINP) were found in samples from homes with PVC wallpaper than without. The number of PVC interior materials was significantly positively correlated with the levels of DEHP and DINP in multi-surface dust. The phthalate levels in multi-surface dust were associated with the interior surface materials, and those in floor dust were directly related to the flooring materials. Our findings show that when using house dust as an exposure assessment, it is very important to note where the samples were collected from. The present report provides useful information about the association between phthalates and dust inside dwellings, which will assist with establishing public health provisions. © 2013. Published by Elsevier B.V. All rights reserved.
β-(1,3)-Glucan Exposure Assessment by Passive Airborne Dust Sampling and New Sensitive Immunoassays▿
Noss, Ilka; Wouters, Inge M.; Bezemer, Gillina; Metwali, Nervana; Sander, Ingrid; Raulf-Heimsoth, Monika; Heederik, Dick J. J.; Thorne, Peter S.; Doekes, Gert
2010-01-01
Associations between house dust-associated β-(1,3)-glucan exposure and airway inflammatory reactions have been reported, while such exposures in early childhood have been suggested to protect against asthma and wheezing. Most epidemiological studies have used reservoir dust samples and an inhibition enzyme immunoassay (EIA) for β-(1,3)-glucan exposure assessment. The objective of this study was to develop inexpensive but highly sensitive enzyme immunoassays to measure airborne β-(1,3)-glucans in low-exposure environments, like homes. Specificities of available anti-β-(1,3)-glucan antibodies were defined by direct and inhibition experiments. Three suitable antibody combinations were selected for sandwich EIAs. β-(1,3)-Glucans in passive airborne dust collected with an electrostatic dust fall collector (EDC) and floor dust from seven homes were measured with the three EIAs. Floor dust samples were additionally analyzed in the inhibition EIA. The sandwich EIAs were sensitive enough for airborne glucan measurement and showed different specificities for commercial glucans, while the β-(1,3)-glucan levels in house dust samples correlated strongly. The feasibility of measuring glucans in airborne dust with the recently introduced EDC method was further investigated by selecting the most suitable of the three EIAs to measure and compare β-(1,3)-glucan levels in the EDC and in floor and actively collected airborne dust samples of the previously performed EDC validation study. The EDC β-(1,3)-glucan levels correlated moderately with β-(1,3)-glucans in actively collected airborne dust and floor dust samples, while the glucan levels in the airborne dust and floor dust samples did not correlate. The combination of the newly developed β-(1,3)-glucan sandwich EIA with EDC sampling now allows assessment in large-scale population studies of exposure to airborne β-(1,3)-glucans in homes or other low-exposure environments. PMID:20038709
Würtz, H; Sigsgaard, T; Valbjørn, O; Doekes, G; Meyer, H W
2005-01-01
A newly developed dustfall device that collects airborne dust by sedimentation has been evaluated in Danish schools. Dust collected over 140 days was compared with airborne dust sampled during single school days and settled floor dust sampled at the end of a school day. Measurements of culturable fungi in air samples corresponded well to those from the dustfall collector in mechanically but not naturally ventilated rooms. Levels of beta(1 --> 3)glucan and culturable fungi in dust from the dustfall collector and settled floor dust did not agree well. Up to 10 times more beta(1 --> 3)glucan per milligram dust was found in the dustfall collectors than in settled floor dust. Only in dust from the dustfall collector was the mass concentration of culturable fungi (cfu/mg) significantly correlated with the degree of dampness. The culturability of fungi in the 140-day dustfall samples tended to be lower than in other types of samples. Nonetheless, the results indicated that the dustfall collector can be used to estimate the median concentration of airborne culturable fungi, provided identical sampling periods are used for all samples. The collector is cost effective and simple to use. Traditional ways of assessing exposure to microorganisms by sampling airborne dust or dust from floors have several disadvantages. In the present paper, a new sampler, the dustfall collector, which collects airborne dust by sedimentation over a period of months, is introduced. Tests of this collector indicate that it can be used to estimate the mean concentration of airborne culturable fungi but not beta(1 --> 3)glucan over a long period and that the method can differentiate between buildings with different levels of water damage.
The purpose of this SOP is to establish a uniform procedure for the collection of indoor floor dust samples in the field. This procedure was followed to ensure consistent data retrieval of dust samples during the Arizona NHEXAS project and the Border study. Keywords: field; vacu...
This SOP describes the method for collecting a floor dust sample from carpet. Dust samples will be collected in the room that the child uses most at home and/or at day care using a High Volume Small Surface Sampler (HVS3). In addition, participants will also be asked to donate a ...
Coronado, Gloria D; Griffith, William C; Vigoren, Eric M; Faustman, Elaine M; Thompson, Beti
2010-12-01
Organophosphate pesticides are commonly used in the United States, and farmworkers are at risk for chronic exposure. Using data from a community randomized trial to interrupt the take-home pathway of pesticide exposure, we examined the association between floor surface type (smooth floor, thin carpet, and thick carpet) and rooms in which dust samples were collected (living room vs. non-living room) and concentrations of azinphos-methyl residues in home environments. We also examined the association between vehicle type (truck, auto, or other) and footwell floor surfaces (carpeted, smooth surface, or no mat) and concentrations of azinphos-methyl in vehicle dust samples. Dust samples were collected from 203 and 179 households and vehicles, respectively. All households had at least one child aged 2-6. Vehicle dust samples were collected from footwells of the vehicle used for commuting to and from work. A total of 183 samples were collected from living rooms, and 20 were collected from other rooms in the home. Forty-two samples were collected from thick carpets, 130 from thin carpets, and 27 from smooth floor surfaces. Thick and thin carpets had a significantly greater dust mass than smooth floor surfaces (6.0 g/m(2) for thick carpets, 7.8 g/m(2) for thin carpets, and 1.5 g/m(2) for smooth surfaces). Of the 179 vehicle samples, 113 were from cars, 34 from trucks, and 32 from other vehicles. Vehicles with no mats had a significantly higher mass of dust (21.3 g) than those with hard mats (9.3 g) but did not differ from vehicles with plush mats (12.0 g). Further research is needed to characterize the environment in which children may be exposed to pesticides.
Coronado, Gloria D.; Griffith, William C.; Vigoren, Eric M.; Faustman, Elaine M.; Thompson, Beti
2010-01-01
Organophosphate pesticides (OPs) are commonly used in the United States, and farm workers are at risk for chronic exposure. Using data from a community randomized trial to interrupt the take-home pathway of pesticide exposure, we examined the association between floor surface type (smooth floor, thin carpet, and thick carpet) and rooms in which dust samples were collected (living room vs. non-living room) and concentrations of azinphos-methyl residues in home environments. We also examined the association between vehicle type (truck, auto, or other) and footwell floor surfaces (carpeted, smooth surface, or no mat) and concentrations of azinphos-methyl in vehicle dust samples. Dust samples were collected from 203 and 179 households and vehicles, respectively. All households had at least one child aged 2–6. Vehicle dust samples were collected from footwells of the vehicle used for commuting to and from work. A total of 183 samples were collected from living rooms, and 20 were collected from other rooms in the home. Forty-two samples were collected from thick carpets, 130 from thin carpets, and 27 from smooth floor surfaces. Thick and thin carpets had a significantly greater dust mass than smooth floor surfaces (6.0 g/m2 for thick carpets, 7.8 g/m2 for thin carpets, and 1.5 g/m2 for smooth surfaces). Of the 179 vehicle samples, 113 were from cars, 34 from trucks, and 32 from other vehicles. Vehicles with no mats had a significantly higher mass of dust (21.3 g) than those with hard mats (9.3 g) but did not differ from vehicles with plush mats (12.0g). Further research is needed to characterize the environment in which children may be exposed to pesticides. PMID:20945243
Exposure to phthalates in house dust and associated allergies in children aged 6-12years.
Ait Bamai, Yu; Araki, Atsuko; Kawai, Toshio; Tsuboi, Tazuru; Saito, Ikue; Yoshioka, Eiji; Cong, Shi; Kishi, Reiko
2016-11-01
Phthalates are widely used as plasticizers in household products. Several studies have reported an association between phthalate exposure and an increased risk of allergies. The present study estimated phthalate exposure in children aged 6-12years and assessed potential correlations with allergies. House dust samples were collected from floors and multi-surface objects >35cm above the floor. Urine samples were collected from the first morning void of the day. Daily phthalate intake (DI dust and DI) was estimated using both house dust and urinary metabolite concentrations. Exposure to di-2-ethylhexyl phthalate (DEHP) in floor dust was associated with parental-reported rhino-conjunctivitis. After stratification by gender, this trend was found to only occur in boys. Furthermore, urinary mono-isobutyl phthalate was inversely associated with parental-reported wheeze in boys. DI dust of benzyl butyl phthalate (BBzP) and DEHP were significantly correlated with DI_BBzP and DI_DEHP, respectively. These correlations were stronger with floor than with multi-surface dust. Our results suggest that, among Japanese children, house dust from low surfaces, such as living room floors, might play a meaningful role in the indoor environmental exposure pathway for BBzP and DEHP. Copyright © 2016 Elsevier Ltd. All rights reserved.
Luczynska, C; Sterne, J; Bond, J; Azima, H; Burney, P
1998-10-01
Studies of house dust mite allergen concentrations suggest large variations both within and between homes. It is likely that different household characteristics influence allergen levels in different locations within the house. To investigate household characteristics associated with higher concentrations of house dust mite allergen in a random sample of houses. Information on indoor environment was obtained from 158 adults aged 20-44. Dust samples were collected from their living room floor, bedroom floor and mattress. Concentrations of Der p 1, the major allergen from the house dust mite Dermatophagoides pteronyssinus, were measured by monoclonal antibody immunoassay. Associations between mite allergen concentrations and household characteristics were examined using censored-normal regression models. Factors that were related to Der p 1 (P = 0.2) in univariate analyses were included in multivariable regression models. Der p 1 was not detected in any location in 10 (6.3%) houses. Geometric mean concentrations of Der p 1 were 1.9 microg/g in living room floor dust, 1.7 microg/g in bedroom floor dust and 2.0 microg/g in mattress dust. Approximately 25% of living room floor and mattress, and over 30% of bedroom floor samples had Der p 1 concentrations greater than 10 microg/g. Household characteristics associated with Der p 1 concentrations in both living room and bedroom were floor level, extractor fan in the kitchen, and age of carpet. Living room Der p 1 concentrations were also associated with gas oven/hob, window condensation, open fires, vacuum cleaner type, smokers in the house and age of house. Bedroom Der p 1 concentrations were also associated with use of blankets and wash temperature of bedding. Mattress Der p 1 concentrations were associated with window condensation, concrete bedroom floor and age of mattress. Different household characteristics were associated with high Der p 1 concentrations in different parts of the house. These findings are relevant to design of allergen avoidance regimes or formulation of policy recommendations for reduction of disease associated with allergen exposure.
Cox, Jennie; Indugula, Reshmi; Vesper, Stephen; Zhu, Zheng; Jandarov, Roman; Reponen, Tiina
2017-10-18
Evaluating fungal contamination indoors is complicated because of the many different sampling methods utilized. In this study, fungal contamination was evaluated using five sampling methods and four matrices for results. The five sampling methods were a 48 hour indoor air sample collected with a Button™ inhalable aerosol sampler and four types of dust samples: a vacuumed floor dust sample, newly settled dust collected for four weeks onto two types of electrostatic dust cloths (EDCs) in trays, and a wipe sample of dust from above floor surfaces. The samples were obtained in the bedrooms of asthmatic children (n = 14). Quantitative polymerase chain reaction (qPCR) was used to analyze the dust and air samples for the 36 fungal species that make up the Environmental Relative Moldiness Index (ERMI). The results from the samples were compared by four matrices: total concentration of fungal cells, concentration of fungal species associated with indoor environments, concentration of fungal species associated with outdoor environments, and ERMI values (or ERMI-like values for air samples). The ERMI values for the dust samples and the ERMI-like values for the 48 hour air samples were not significantly different. The total cell concentrations of the 36 species obtained with the four dust collection methods correlated significantly (r = 0.64-0.79, p < 0.05), with the exception of the vacuumed floor dust and newly settled dust. In addition, fungal cell concentrations of indoor associated species correlated well between all four dust sampling methods (r = 0.68-0.86, p < 0.01). No correlation was found between the fungal concentrations in the air and dust samples primarily because of differences in concentrations of Cladosporium cladosporioides Type 1 and Epicoccum nigrum. A representative type of dust sample and a 48 hour air sample might both provide useful information about fungal exposures.
The purpose of this SOP is to establish a uniform procedure for the collection of indoor floor dust samples in the field. This procedure was followed to ensure consistent data retrieval of dust samples during the Arizona NHEXAS project and the "Border" study. Keywords: field; va...
Bi, Xiaolong; Yuan, Shoujun; Pan, Xiaojun; Winstead, Cherese; Wang, Qiquan
2015-01-01
This study aimed to compare and assess phthalate contamination in various indoor environments. In this study, 44 floor dust samples from different indoor environments in Delaware, USA were collected and analyzed for 14 phthalates using gas chromatography-mass spectrometry. Phthalates were detected in all dust samples with the total concentration ranging from 84 to 7117 mg kg(-1). DEHP (di-2-ethylhexyl phthalate), BzBP (benzylbutyl phthalate), DBP (dibutyl phthalate), and DiBP (di-isobutyl phthalate) were both the most frequently and abundantly detected phthalates. The average concentration of total phthalates in dust from offices, student dorms, gyms, stores, and daycare centers was found to be significantly or insignificantly (P = 0.05) higher than that in dust from houses and apartments. Plastic flooring materials and the application of floor care chemical products were positively associated with total phthalate concentration in floor dust. Toxicological risk assessment indicated that an investigated daycare center in this study was the only indoor environment that may cause the intake amount of DEHP of infants, toddlers, and children via dust ingestion to exceed the reference dose established by the U.S. Environmental Protection Agency (USEPA). Regular monitoring on phthalate contamination in sensitive indoor environments is recommended.
NHEXAS PHASE I ARIZONA STUDY--METALS IN DUST ANALYTICAL RESULTS
The Metals in Dust data set contains analytical results for measurements of up to 11 metals in 562 dust samples over 388 households. Samples were taken by collecting dust samples from the indoor floor areas in the main room and in the bedroom of the primary resident. In additio...
NHEXAS PHASE I MARYLAND STUDY--METALS IN DUST ANALYTICAL RESULTS
The Metals in Dust data set contains analytical results for measurements of up to 4 metals in 282 dust samples over 80 households. Samples were obtained by collecting dust samples from the indoor floor areas in the main activity room using a modified vacuum cleaner device that c...
NHEXAS PHASE I MARYLAND STUDY--PESTICIDES IN DUST ANALYTICAL RESULTS
The Pesticides in Dust data set contains analytical results for measurements of up to 9 pesticides in 126 dust samples over 50 households. Samples were obtained by collecting dust samples from the indoor floor areas in the main activity room using a modified vacuum cleaner devic...
Douwes, J; van der Sluis, B; Doekes, G; van Leusden, F; Wijnands, L; van Strien, R; Verhoeff, A; Brunekreef, B
1999-03-01
Epidemiologic studies have demonstrated an association between indoor fungal growth and respiratory symptoms. However, in only a few studies was fungal exposure actually measured. The purpose of this study was to evaluate the measurement by enzyme immunoassay of extracellular polysaccharides of Aspergillus and Penicillium species (EPS-Asp/Pen ) in house dust as a marker for fungal exposure and to study the relations between EPS-Asp/Pen levels and home dampness and respiratory symptoms in children. Extracts of house dust samples from bedroom and living room floors and mattresses from homes of 31 children with chronic respiratory symptoms and 29 children with no chronic respiratory symptoms were analyzed for EPS-Asp/Pen. EPS-Asp/Pen were readily detectable (40 to 46,513 nanogram equivalent/g dust) in 161 house dust extracts, with highest concentrations in living room floor dust. EPS-Asp/Pen levels were 2 to 3 times higher on carpeted floors than on smooth floors. EPS-Asp/Pen were significantly correlated with total culturable fungi (r = 0.3 to 0.5) and with house dust mite allergens (r = 0.3 to 0.5). EPS-Asp/Pen levels in living room floor dust were positively associated with occupant-reported home dampness. This was not observed for EPS-Asp/Pen in bedroom floor and mattress dust. EPS-Asp/Pen levels in living room floor dust were positively associated with respiratory symptoms. EPS-Asp/Pen in bedroom floor and mattress dust showed a reversed association with respiratory symptoms, possibly because of allergen-avoidance measures taken in the bedroom. The enzyme immunoassay for fungal EPS-Asp/Pen may be a useful method for exposure assessment of indoor fungi.
U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--METALS IN DUST ANALYTICAL RESULTS
The Metals in Dust data set contains analytical results for measurements of up to 11 metals in 182 dust samples over 91 households. Samples were taken by collecting dust samples from the indoor floor areas in the main room and in the bedroom of the primary resident. In addition...
Ali, Nadeem; Ismail, Iqbal Mohammad Ibrahim; Khoder, Mamdouh; Shamy, Magdy; Alghamdi, Mansour; Costa, Max; Ali, Lulwa Naseer; Wang, Wei; Eqani, Syed Ali Musstjab Akber Shah
2016-12-15
This study reports levels and profiles of polycyclic aromatic hydrocarbons (PAHs) in dust samples collected from three different microenvironments (cars, air conditioner (AC) filters and household floor dust) of Jeddah, Saudi Arabia (KSA) and Kuwait. To the best of our knowledge, this is first study reporting PAHs in indoor microenvironments of KSA, which makes these findings important. Benzo(b)fluoranthene (BbF), benzo(a)pyrene (BaP), phenanthrene (Phe), and pyrene (Pyr) were found to be the major chemicals in dust samples from all selected microenvironments. ΣPAHs occurred at median concentrations (ng/g) of 3450, 2200, and 2650 in Saudi AC filter, car and household floor dust, respectively. The median levels (ng/g) of ΣPAHs in Kuwaiti car (950) and household floor (1675) dust samples were lower than Saudi dust. The PAHs profile in Saudi dust was dominated by high molecular weight (HMW) (4-5 ring) PAHs while in Kuwaiti dust 3 ring PAHs have marked contribution. BaP equivalent, a marker for carcinogenic PAHs, was high in Saudi household floor and AC filter dust with median levels (ng/g) of 370 and 455, respectively. Different exposure scenarios, using 5th percentile, median, mean, and 95th percentile levels, were estimated for adults and toddlers. For Saudi and Kuwaiti toddlers worst exposure scenario of ΣPAHs was calculated at 175 and 85ng/kg body weight/day (ng/kgbw/d), respectively. For Saudi toddlers, the calculated worst exposure scenarios for carcinogenic BaP (27.7) and BbF (29.3ng/kgbw/d) was 2-4 times higher than Kuwaiti toddlers. This study is based on small number of samples which necessitate more detailed studies for better understanding of dynamics of PAHs in the indoor environments of this region. Nevertheless, our finding supports the ongoing exposure of organic pollutants to population that accumulates indoor. Copyright © 2016. Published by Elsevier B.V.
RELATIONSHIPS OF METALS IN FLOOR DUST AND ON THE HANDS OF TODDLERS
Toddlers are characterized by their frequent hand-to-mouth activity and exploratory behavior. This puts them at risk for exposure to environmental contaminants. Wipe samples are traditionally used to collect dust samples in homes. The assumption is that dust samples are indicativ...
NHEXAS PHASE I ARIZONA STUDY--PESTICIDES IN DUST ANALYTICAL RESULTS
The Pesticides in Dust data set contains analytical results for measurements of up to 3 pesticides in 437 dust samples over 278 households. Samples were taken by collecting dust from the indoor floor areas in the main room and in the bedroom of the primary resident. The primary...
Ali, Nadeem; Eqani, Syed Ali Musstjab Akber Shah; Ismail, Iqbal Mohammad Ibrahim; Malarvannan, Govindan; Kadi, Mohammad W; Albar, Hussain Mohammed Salem; Rehan, Mohammad; Covaci, Adrian
2016-11-01
Different flame retardants (FRs) namely polybrominated diphenyl ethers (PBDEs), emerging brominated/chlorinated flame retardants (Br/Cl FRs), and organophosphate FRs (OPFRs) were analyzed in cars, air conditioner (AC) filters and floor dust of different households from Jeddah, Kingdom of Saudi Arabia (KSA). To the best of our knowledge, this is first study in literature reporting emerging Br/Cl FRs and OPFRs in AC filter dust and also first to report on their occurrence in dust from KSA. Chlorinated alkyl phosphate, penta-BDEs, BDE-209, and decabromodiphenylethane (DBDPE) were the major chemicals in dust samples from all microenvironments. ΣOPFRs occurred at median concentrations (ng/g dust) of 15,400, 10,500, and 3750 in AC filter, car and house floor dust, respectively. For all analyzed chemicals, relatively lower levels were observed in floor dust than car and AC filter dust. The profiles of FRs in car dust were different from AC filter and floor dust, which reflected their wider application as FR and plasticizer in variety of household and commercial products. For toddlers, assuming high dust intake and 95th percentile concentrations, the computed exposure estimation for BDE-99 was higher than RfD values. Copyright © 2016 Elsevier B.V. All rights reserved.
Migration of DEHP and DINP into dust from PVC flooring products at different surface temperature.
Jeon, Seunghwan; Kim, Ki-Tae; Choi, Kyungho
2016-03-15
Phthalates are important endocrine disrupting chemicals that have been linked to various adverse human health effects. Phthalates are ubiquitously present in indoor environment and could enter humans. Vinyl or PVC floorings have been recognized as one of important sources of phthalate release to indoor environment including house dust. In the present study, we estimated the migration of di(2-ethylhexyl)phthalate (DEHP) and di-isononyl phthalate (DINP) from the flooring materials into the dust under different heating conditions. For this purpose, a small chamber specifically designed for the present study and a Field and Laboratory Emission Cell (FLEC) were used, and four major types of PVC flooring samples including two UV curing paint coated, an uncoated residential, and a wax-coated commercial type were tested. Migration of DEHP was observed for an uncoated residential type and a wax-coated commercial type flooring. After 14 days of incubation, the levels of DEHP in the dust sample was determined at room temperature on average (standard deviation) at 384 ± 19 and 481 ± 53 μg/g, respectively. In contrast, migration of DINP was not observed. The migration of DEHP was strongly influenced by surface characteristics such as UV curing coating. In the residential flooring coated with UV curing paint, migration of DEHP was not observed at room temperature. But under the heated condition, the release of DEHP was observed in the dust in the FLEC. Migration of DEHP from flooring materials increased when the flooring was heated (50 °C). In Korea, heated flooring system, or 'ondol', is very common mode of heating in residential setting, therefore the contribution of PVC flooring to the total indoor DEHP exposure among general population is expected to be greater especially during winter season when the floor is heated. Copyright © 2015 Elsevier B.V. All rights reserved.
NHEXAS PHASE I ARIZONA STUDY--METALS-XRF IN DUST ANALYTICAL RESULTS
The Metals-XRF in Dust data set contains X-ray fluorescence (XRF) analytical results for measurements of up to 27 metals in 384 dust samples over 384 households. Samples were taken by collecting dust from the indoor floor areas in the main room and in the bedroom of the primary ...
U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--PESTICIDES IN DUST ANALYTICAL RESULTS
The Pesticides in Dust data set contains analytical results for measurements of up to 8 pesticides in 91 dust samples over 91 households. Samples were taken by collecting dust from the indoor floor areas in the main room and in the bedroom of the primary resident. The primary p...
U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--PAHS IN DUST ANALYTICAL RESULTS
The PAHs in Dust data set contains the analytical results for measurements of up to 21 polynuclear aromatic hydrocarbons (PAHs) in 91 dust samples over 91 households. Samples were taken by collecting dust from the indoor floor areas from the main room and in the bedroom of the p...
Muenhor, Dudsadee; Moon, Hyo-Bang; Lee, Sunggyu; Goosey, Emma
2018-01-02
This study was undertaken to investigate levels of organophosphorus flame retardants (PFRs) and phthalates in floor and road dust from a manual e-waste dismantling facility and nearby communities in Thailand. Concentrations of Σ10 PFRs and Σ6 phthalates in floor dust from the facility were approximately 36-1,700 and 86,000-790,000 ng g -1 , whereas those from the communities were about 13-9,200 and 44,000-2,700,000 ng g -1 , respectively. The highest content of Σ10 PFRs (9,200 ng g -1 ) and Σ6 phthalates (2,700,000 ng g -1 ) in indoor dust was both detected in the dust sampled from a house with no prevailing winds located 350 m northeast of the facility. Levels of Σ10 PFRs and Σ6 phthalates in road dust from the facility were around 1,100-2,100 and 40,000-670,000 ng g -1 , while those from the residences were about 650-2,000 and 27,000-650,000 ng g -1 , respectively. Concentrations of Σ10 PFRs (2,100 ng g -1 ) and Σ6 phthalates (670,000 ng g -1 ) in road dust were greatest in the dust collected from the facility. For the distributional pattern, TBEP (tris (2-butoxyethyl) phosphate) was the main PFR in residential dust, whereas TPP (triphenyl phosphate) was the major PFR in facility dust. TBEP was also found to be the most prominent PFR in all road dust samples. Furthermore, DEHP (di-2-ethylhexyl phthalate) was the most abundant phthalate congener in both floor and road dust samples. Under realistic high-end scenarios of environmental exposure to DEHP, Thai toddlers (25.29 µg kg -1 bw day -1 ) in the adjacent communities were exposed above the US EPA's (United States Environmental Protection Agency) reference dose (RfD) for this congener (20 µg kg -1 bw day -1 ). Our data reveal that the PFR and phthalate-containing products at the residences are a likely substantial source of PFRs and phthalates to the surrounding indoor environment, and humans can be exposed to PFRs and phthalates in their dwellings via the settled floor dust.
U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--METALS/XRF IN DUST ANALYTICAL RESULTS
The Metals-XRF in Dust data set contains X-ray fluorescence (XRF) analytical results for measurements of up to 27 metals in 91 dust samples over 91 households. Samples were taken by collecting dust from the indoor floor areas in the main room and in the bedroom of the primary re...
Kamal, Ali; Burke, Janet; Vesper, Stephen; Batterman, Stuart; Vette, Alan; Godwin, Christopher; Chavez-Camarena, Marina; Norris, Gary
2014-01-01
The Near-Road Exposures and Effects of Urban Air Pollutants Study (NEXUS) investigated the impact of exposure to traffic-related air pollution on the respiratory health of asthmatic children in Detroit, Michigan. Since indoor mold exposure may also contribute to asthma, floor dust samples were collected in participants homes (n = 112) to assess mold contamination using the Environmental Relative Moldiness Index (ERMI). The repeatability of the ERMI over time, as well as ERMI differences between rooms and dust collection methods, was evaluated for insights into the application of the ERMI metric. ERMI values for the standard settled floor dust samples had a mean ± standard deviation of 14.5 ± 7.9, indicating high levels of mold contamination. ERMI values for samples collected from the same home 1 to 7 months apart (n = 52) were consistent and without systematic bias. ERMI values for separate bedroom and living room samples were highly correlated (r = 0.69, n = 66). Vacuum bag dust ERMI values were lower than for floor dust but correlated (r = 0.58, n = 28). These results support the use of the ERMI to evaluate residential mold exposure as a confounder in air pollution health effects studies.
Meyer, H W; Würtz, H; Suadicani, P; Valbjørn, O; Sigsgaard, T; Gyntelberg, F
2005-01-01
In this stratified cross-sectional study in eight 'wet' and seven 'dry' schools, 1024 adolescent school children reported potentially building-related symptoms (BRS) in self-administrated questionnaires. From their classrooms dust samples were collected from floors, ventilation ducts, and air; settled dust was collected in cardboard boxes over a period of 5 months. Measurements of temperature, relative humidity and CO2 were performed. BRS were strongly associated with personal factors like recent airway infections, hay fever, asthma and psycho-social work load, but also to molds in floor dust and presence of mechanical ventilation. The association between molds in floor dust and BRS has in stratified analyses shown a strong association among adolescent school boys, and no association among adolescent school girls using multivariable analyses controlling for relevant confounders. In contrast to the menstruating school girls, the symptoms among the small group of not yet menstruating girls were associated with the levels of molds in floor dust. Their symptom prevalences were very similar to those of the boys. This finding makes us suggest a new hypothesis: The higher endogenous estrogen levels of sexually matured adolescent females seems to protect them from the effects of molds in dust, despite their overall higher symptom prevalence. In this cross-sectional epidemiological study of adolescent school children we found independent significant positive associations between building-related symptoms and viable molds in floor dust in boys and non-menstruating girls. In contrast, no such associations were seen among menstruating girls. The identification of these two susceptible groups adds further support the relevance of minimizing sources of dust and mold exposure.
Saito, Rena; Park, Ju-Hyeong; LeBouf, Ryan; Green, Brett J.; Park, Yeonmi
2017-01-01
Gas chromatography-tandem mass spectrometry (GC-MS/MS) was used to detect fungal secondary metabolites. Detection of verrucarol, the hydrolysis product of Stachybotrys chartarum macrocyclic trichothecene (MCT), was confounded by matrix effects associated with heterogeneous indoor environmental samples. In this study, we examined the role of dust matrix effects associated with GC-MS/ MS to better quantify verrucarol in dust as a measure of total MCT. The efficiency of the internal standard (ISTD, 1,12-dodecanediol), and application of a matrix-matched standard correction method in measuring MCT in floor dust of water-damaged buildings was additionally examined. Compared to verrucarol, ISTD had substantially higher matrix effects in the dust extracts. The results of the ISTD evaluation showed that without ISTD adjustment, there was a 280% ion enhancement in the dust extracts compared to neat solvent. The recovery of verrucarol was 94% when the matrix-matched standard curve without the ISTD was used. Using traditional calibration curves with ISTD adjustment, none of the 21 dust samples collected from water damaged buildings were detectable. In contrast, when the matrix-matched calibration curves without ISTD adjustment were used, 38% of samples were detectable. The study results suggest that floor dust of water-damaged buildings may contain MCT. However, the measured levels of MCT in dust using the GC-MS/MS method could be significantly under- or overestimated, depending on the matrix effects, the inappropriate ISTD, or combination of the two. Our study further shows that the routine application of matrix-matched calibration may prove useful in obtaining accurate measurements of MCT in dust derived from damp indoor environments, while no isotopically labeled verrucarol is available. PMID:26853932
Saito, Rena; Park, Ju-Hyeong; LeBouf, Ryan; Green, Brett J; Park, Yeonmi
2016-01-01
Gas chromatography-tandem mass spectrometry (GC-MS/MS) was used to detect fungal secondary metabolites. Detection of verrucarol, the hydrolysis product of Stachybotrys chartarum macrocyclic trichothecene (MCT), was confounded by matrix effects associated with heterogeneous indoor environmental samples. In this study, we examined the role of dust matrix effects associated with GC-MS/MS to better quantify verrucarol in dust as a measure of total MCT. The efficiency of the internal standard (ISTD, 1,12-dodecanediol), and application of a matrix-matched standard correction method in measuring MCT in floor dust of water-damaged buildings was additionally examined. Compared to verrucarol, ISTD had substantially higher matrix effects in the dust extracts. The results of the ISTD evaluation showed that without ISTD adjustment, there was a 280% ion enhancement in the dust extracts compared to neat solvent. The recovery of verrucarol was 94% when the matrix-matched standard curve without the ISTD was used. Using traditional calibration curves with ISTD adjustment, none of the 21 dust samples collected from water damaged buildings were detectable. In contrast, when the matrix-matched calibration curves without ISTD adjustment were used, 38% of samples were detectable. The study results suggest that floor dust of water-damaged buildings may contain MCT. However, the measured levels of MCT in dust using the GC-MS/MS method could be significantly under- or overestimated, depending on the matrix effects, the inappropriate ISTD, or combination of the two. Our study further shows that the routine application of matrix-matched calibration may prove useful in obtaining accurate measurements of MCT in dust derived from damp indoor environments, while no isotopically labeled verrucarol is available.
Improved system for floor cleaning in health care facilities.
Schmidt, E A; Coleman, D L; Mallison, G F
1984-01-01
A new system has been developed for sanitizing floors in hospitals; this system replaces the traditional procedure of daily dusting and wet mopping with a disinfectant-detergent solution and periodic buffing . This new system relies on a sequence of procedures consisting of dust mopping using a chemically treated dust mop, machine buffing of a sprayed-on polymer treatment, and a second dust mopping . The effectiveness of the procedures was evaluated by means of surface sampling for bacterial contamination and air sampling for airborne bacteria and dust. The level of bacterial contamination on the floors was reduced by 93.6% by using the new system, compared with 79.8% by using the conventional process of dust mopping and wet mopping with a disinfectant solution. The levels of airborne bacteria during and after the individual procedures did not vary significantly from the initial level (123.6 CFU/per m3 of air). A survey of representative colonies from air samples revealed staphylococci, gram-positive bacilli, gram-positive diplococci, yeast cells, and infrequent gram-negative rods. The distribution at the conclusion of the sanitizing process was similar to that at the outset. Similarly, the levels of airborne dust measured during and after the individual procedures did not vary significantly from the initial level. When compared with the traditional method of cleaning by wet mopping , the new method was significantly more effective in removal of microbial contamination and required less labor. PMID:6742835
Vitamin D receptor Fok1 polymorphism and blood lead concentration in children.
Haynes, Erin N; Kalkwarf, Heidi J; Hornung, Richard; Wenstrup, Richard; Dietrich, Kim; Lanphear, Bruce P
2003-01-01
Variation in blood lead concentration is caused by a complex interaction of environmental, social, nutritional, and genetic factors. We evaluated the association between blood lead concentration and a vitamin D receptor (VDR) gene polymorphism. Environmental samples and blood were analyzed for lead, nutritional and behavioral factors were assessed, and VDR -Fok1 genotype was determined in 245 children. We found a significant interaction between floor dust lead and genotype on blood lead concentration. For every 1 microg/ft(2) increase in floor dust, children with VDR -FF genotype had a 1.1% increase in blood lead [95% confidence interval (CI), 0.69-1.5], VDR -Ff, 0.53% increase (95% CI, 0.1-0.92), and VDR -ff, 3.8% increase (95% CI, 1.2-6.3); however, at floor dust levels < 10 microg/ft(2), children with VDR -ff had the lowest blood lead concentrations. These data suggest that VDR -Fok1 is an effect modifier of the relationship of floor dust lead exposure and blood lead concentration. PMID:14527848
Bennett, D. H.; Moran, R. E.; Wu, X. (May); Tulve, N. S.; Clifton, M. S.; Colón, M.; Weathers, W.; Sjödin, A.; Jones, R.; Hertz-Picciotto, I.
2016-01-01
Polybrominated diphenyl ethers (PBDEs) are used as flame retardants in furniture foam, electronics, and other home furnishings. A field study was conducted that enrolled 139 households from California, which has had more stringent flame retardant requirements than other countries and areas. The study collected passive air, floor and indoor window surface wipes, and dust samples (investigator collected using an HVS3 and vacuum cleaner) in each home. PentaBDE and BDE209 were detected in the majority of the dust samples and many floor wipe samples, but the detection in air and window wipe samples was relatively low. Concentrations of each PBDE congener in different indoor environmental media were moderately correlated, with correlation coefficients ranging between 0.42 and 0.68. Correlation coefficients with blood levels were up to 0.65 and varied between environmental media and age group. Both investigator-collected dust and floor wipes were correlated with serum levels for a wide range of congeners. These two sample types also had a relatively high fraction of samples with adequate mass for reliable quantification. In 42 homes, PBDE levels measured in the same environmental media in the same home 1 year apart were statistically correlated (correlation coefficients: 0.57–0.90), with the exception of BDE209 which was not well correlated longitudinally. PMID:24832910
Bennett, D H; Moran, R E; Wu, X May; Tulve, N S; Clifton, M S; Colón, M; Weathers, W; Sjödin, A; Jones, R; Hertz-Picciotto, I
2015-04-01
Polybrominated diphenyl ethers (PBDEs) are used as flame retardants in furniture foam, electronics, and other home furnishings. A field study was conducted that enrolled 139 households from California, which has had more stringent flame retardant requirements than other countries and areas. The study collected passive air, floor and indoor window surface wipes, and dust samples (investigator collected using an HVS3 and vacuum cleaner) in each home. PentaBDE and BDE209 were detected in the majority of the dust samples and many floor wipe samples, but the detection in air and window wipe samples was relatively low. Concentrations of each PBDE congener in different indoor environmental media were moderately correlated, with correlation coefficients ranging between 0.42 and 0.68. Correlation coefficients with blood levels were up to 0.65 and varied between environmental media and age group. Both investigator-collected dust and floor wipes were correlated with serum levels for a wide range of congeners. These two sample types also had a relatively high fraction of samples with adequate mass for reliable quantification. In 42 homes, PBDE levels measured in the same environmental media in the same home 1 year apart were statistically correlated (correlation coefficients: 0.57-0.90), with the exception of BDE209 which was not well correlated longitudinally. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sterling, D.A.; Roegner, K.C.; Lewis, R.D.
Childhood exposure to lead has been demonstrated to result in health effects and lead-contaminated household dust is a primary exposure source. There is a need to establish reliable methods for sampling surfaces to determine levels of lead contamination. Three vacuums (HVS3, GS80, and MVM) and one wipe method were evaluated for the collection of household floor dust under field sampling conditions within a Superfund site and demographically similar control area. Side-by-side floor samples were taken from three locations within 41 randomly selected households between August and September 1995: a child's bedroom, primary play area, and primary entrance. Analysis was performedmore » to assess the relative collection performance of each sampler, spatial distribution of lead within a household, and correlation of lead loading with observed blood lead level, and to determine if discrete or composites samples were more predictive of blood lead levels. Approximately 90% of the floor surfaces were carpeted. The rank order of sampling methods from greatest to lowest collection efficiency was HVS3 > G80 > wipe > MVM. The HVS3 had the highest level of precision (CV = 0.05), with the GS80 and wipe precisions 0.48 and 0.053, respectively.« less
Niu, Dong; Qiu, Yanling; Li, Li; Zhou, Yihui; Du, Xinyu; Zhu, Zhiliang; Chen, Ling; Lin, Zhifen
2018-04-24
House dust is the main source of human exposure to flame retardants by ingestion. This study investigated the occurrence of polybrominated diphenyl ethers (PBDEs) in indoor dust from 22 houses in Shanghai, China. House dust was separately collected from the floor and elevated furnishings surface (mostly between 0.5 and 2 m height) for comparison. The concentrations of ∑ 22 PBDEs ranged from 19.4 to 3280 ng/g (with a geometric mean of 203 ng/g) and from 55.1 to 792 ng/g (with a geometric mean of 166 ng/g) in floor dust (FD) and elevated surface dust (ESD), respectively. BDE-209 was the predominant congener, accounting for about 73.1% of total PBDE burdens. In terms of congener profiles, the comparison of FD and ESD revealed no significant differences except for the ratio of BDE-47/BDE-99. ESD samples displayed a ratio of BDE-47/BDE-99 very similar to commercial penta-BDE products DE-71 while the ratio in FD was exceptionally higher. Significant correlation was found between concentrations of commercial penta-BDE compositions in FD and ESD (p < 0.05). Except for some occasional values, PBDE levels in house dust exhibited temporal stability. Human exposure to PBDEs via dust ingestion was estimated. The highest daily intake of PBDEs was for toddlers by using 95th percentile concentrations of PBDEs via high dust ingestion in FD (23.07 ng/kg bw/day). About 20-fold difference in exposure estimates between toddlers and adults supports that toddlers are facing greater risk from indoor floor dust. Expectedly, this study highlighted the point that residents in Shanghai were exposed to low doses of PBDEs in house dust.
Zheng, Xiaobo; Qiao, Lin; Covaci, Adrian; Sun, Runxia; Guo, Huiying; Zheng, Jing; Luo, Xiaojun; Xie, Qilai; Mai, Bixian
2017-10-01
Indoor dust has been widely used to monitor flame retardants (FRs) in indoor environment, but most studies only focused on floor dust. In the present study, FRs were examined in indoor dust from different locations. Dust from air conditioner (AC) filters, beddings, floor, and windows in bedrooms, and dust from AC filters, printer table surface, computer table surface, floor, and windows in offices were collected, respectively. Polybrominated diphenyl ether congener 209 (BDE 209) and decabromodiphenyl ethane (DBDPE) were the most abundant brominated flame retardants (BFRs), and tris(chloroisopropyl) phosphate (TCIPP), tris(1,3-dichloroisopropyl) phosphate (TDCIPP), and triphenyl phosphate (TPHP) were the most abundant phosphate flame retardants (PFRs). In bedrooms, the AC filter dust had the highest median levels of BDE 209 (536 ng/g) and DBDPE (2720 ng/g), while bed dust had the highest median levels of ΣPFRs (2750 ng/g) among dust samples. In offices, printer table dust had higher median levels of BDE 209 (1330 ng/g), DBDPE (8470 ng/g), and ΣPFRs (11,000 ng/g) than those in other dust samples. The high dust ingestion values of BDE 209, DBDPE, and individual PFR were 0.28, 1.20, and <0.01-0.32 ng/kg bw/day and 7.37, 31.2, and <0.01-4.54 ng/kg bw/day for BDE 209, DBDPE, and individual PFR for adults and toddlers, respectively. The high dermal exposure values of individual PFR during sleeping were <0.01-0.23 and <0.01-0.36 ng/kg bw/day for adults and toddlers, respectively. More human exposure pathways other than dust ingestion should be considered, such as the dermal contact with beddings and furniture. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Kolarik, Barbara; Bornehag, Carl-Gustaf; Naydenov, Kiril; Sundell, Jan; Stavova, Petra; Nielsen, Ole Faurskov
Phthalate esters are chemical compounds with a broad range of applications. Recently, we have shown that significantly higher dust concentration of di(2-ethylhexyl) phthalate (DEHP) was found in Bulgarian homes of children with asthma or allergies compared to healthy children. The concentration of DEHP was found to be significantly associated with wheezing in the last 12 months as reported by parents. The objective of the current study was to examine the associations between concentrations of phthalates in settled dust collected in Bulgarian homes and building characteristics and cleaning habits. Dust samples from the child's bedroom were collected in 177 homes and analysed for the content of dimethyl phthalate (DMP), diethyl phthalate (DEP), di-n-butyl phthalate (DnBP), butyl benzyl phthalate (BBzP), di- n-octyl phthalate (DnOP) and DEHP. Information on building characteristics and family habits were collected from parental reports in questionnaires and from inspectors' observations in the homes. Significantly higher concentrations of BBzP, DEHP and DnOP in indoor dust were found in homes where polishing agents were used, compared to homes where such products were not used. The highest concentrations of DEHP, BBzP and DnOP were found in homes with the combination of a low frequency of dusting and the use of polish. There was no difference in phthalate concentrations between inspector-observed balatum flooring (PVC or linoleum) and wood flooring as well as between PVC, as determined by Raman spectra, and wood flooring. However, in a sub-group of homes with no use of polish, the concentration of DEHP was higher in homes with inspector-observed balatum compared with wood flooring but the difference was not significant may be due to a too small sample size.
Ozone reaction characteristics of indoor floor dust examined in the emission cell "FLEC".
Vibenholt, Anni; Clausen, Per Axel; Wolkoff, Peder
2014-07-01
Ozone reacts with C-C double bonds in common indoor VOCs and SVOCs contained in indoor dust and may be catalytically degraded on dust surfaces. The reaction between floor dust and ozone was investigated in the FLEC emission cell at different ozone concentrations and relative humidities (0%, 25%, and 50% RH). One gram of dust was spread on a clean stainless steel plate which was placed in the FLEC. Steady state reaction rate (kDust) at 2.2 ppm ozone was determined for four different floor dust samples collected in Danish homes and offices. This high concentration was necessary in order to measure and determine the consumption in the outlet air from the FLEC. Measurements were corrected for FLEC wall effects by subtraction of the steady state reaction rate between ozone and a FLEC on a stainless steel plate without dust (kFLEC). The composition of organic compounds in the dust was analyzed by pressurized liquid extraction and thermal desorption GC-MS before and after ozone exposure. kFLEC was independent of the ozone concentration and the reaction was treated as first order. The same was indicated for kDust since it remained unchanged at 2.2 and 1.6 ppm ozone for one dust sample. However, the measured kDust in the FLEC should be considered an average rate constant due to the FLEC geometry. kDust was in the range 0.039-0.14s(-1) pr. g dust at 50% RH. kDust was 3 times higher at 25% RH than at 50% RH and 6 times higher than at 0% RH. The inhomogeneity of the dust was assessed by experiments in triplicate with a new portion of dust each time. The relative standard deviation of kDust at 50% RH was 6-20%. The major identified compounds before and after ozone exposure included aldehydes, saturated and unsaturated linear alkanoic acids, benzoic acid and their methyl esters, dimethyl esters, phthalates and traces of α-pinene and limonene. Substantial increase of C7-C9 aldehydes was observed after ozone exposure. Copyright © 2014 Elsevier Ltd. All rights reserved.
Variability of indoor fungal microbiome of green and non-green low-income homes in Cincinnati, Ohio.
Coombs, Kanistha; Taft, Diana; Ward, Doyle V; Green, Brett J; Chew, Ginger L; Shamsaei, Behrouz; Meller, Jaroslaw; Indugula, Reshmi; Reponen, Tiina
2018-01-01
"Green" housing is designed to use low-impact materials, increase energy efficiency and improve occupant health. However, little is known about the indoor mycobiome of green homes. The current study is a subset of a multicenter study that aims to investigate the indoor environment of green homes and the respiratory health of asthmatic children. In the current study, the mycobiome in air, bed dust and floor dust was compared between green (study site) and non-green (control site), low-income homes in Cincinnati, Ohio. The samples were collected at baseline (within four months following renovation), and 12months after the baseline at the study site. Parallel sample collection was conducted in non-green control homes. Air samples were collected by PM2.5 samplers over 5-days. Bed and floor dust samples were vacuumed after the air sampling was completed. The DNA sample extracts were analyzed using ITS amplicon sequencing. Analysis indicated that there was no clear trend in the fungal communities between green and non-green homes. Instead, fungal community differences were greatest between sample types - air, bed, and floor. Microbial communities also changed substantially between sampling intervals in both green and non-green homes for all sample types, potentially indicating that there was very little stability in the mycobiomes. Research gaps remain regarding how indoor mycobiome fluctuates over time. Longer follow-up periods might elucidate the effect of green renovation on microbial load in buildings. Copyright © 2017 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jing Ma; Rudolf Addink; Sehun Yun
2009-10-01
In this study, 11 2,3,7,8-substituted PBDD/Fs and 10 polybrominated diphenyl ether (PBDE) congeners were determined in electronic shredder waste, workshop-floor dust, soil, and leaves (of plants on the grounds of the facility) from a large-scale electronic wastes (e-waste) recycling facility and in surface soil from a chemical-industrial complex (comprising a coke-oven plant, a coal-fired power plant, and a chlor-alkali plant) as well as agricultural areas in eastern China. Total PBDD/F concentrations in environmental samples were in the range of 113-818 pg/g dry wt (dw) for leaves, 392-18,500 pg/g dw for electronic shredder residues, 716-80,0000 pg/g dw for soil samples, andmore » 89,600-14,3000 pg/g dw for workshop-floor dust from the e-waste recycling facility and in a range from nondetect (ND) to 427 pg/g dw in soil from the chemical-industrial complex. The highest mean concentrations of total PBDD/Fs were found in soil samples and workshop-floor dust from the e-waste recycling facility. The dioxin-like toxic equivalent (measured as TEQ) concentrations of PBDD/Fs were greater than the TEQs of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) reported in our previous study for the same set of samples. The concentrations of PBDFs were several orders of magnitude higher than the concentrations of PBDDs in samples from the e-waste facility or from soil from the chemical-industrial complex. A significant correlation was found between the concentrations of {Sigma}PBDD/Fs and {Sigma}PBDEs (r = 0.769, p < 0.01) and between SPBDD/Fs and the previously reported SPCDD/F concentrations (r = 0.805, p < 0.01). The estimated daily human intakes of TEQs contributed by PBDD/Fs via soil/dust ingestion and dermal exposures in e-waste recycling facilities were higher than the intakes of TEQs contributed by PCDD/Fs, calculated in our previous study. 45 refs., 2 figs., 2 tabs.« less
Human Occupancy as a Source of Indoor Airborne Bacteria
Hospodsky, Denina; Qian, Jing; Nazaroff, William W.; Yamamoto, Naomichi; Bibby, Kyle; Rismani-Yazdi, Hamid; Peccia, Jordan
2012-01-01
Exposure to specific airborne bacteria indoors is linked to infectious and noninfectious adverse health outcomes. However, the sources and origins of bacteria suspended in indoor air are not well understood. This study presents evidence for elevated concentrations of indoor airborne bacteria due to human occupancy, and investigates the sources of these bacteria. Samples were collected in a university classroom while occupied and when vacant. The total particle mass concentration, bacterial genome concentration, and bacterial phylogenetic populations were characterized in indoor, outdoor, and ventilation duct supply air, as well as in the dust of ventilation system filters and in floor dust. Occupancy increased the total aerosol mass and bacterial genome concentration in indoor air PM10 and PM2.5 size fractions, with an increase of nearly two orders of magnitude in airborne bacterial genome concentration in PM10. On a per mass basis, floor dust was enriched in bacterial genomes compared to airborne particles. Quantitative comparisons between bacterial populations in indoor air and potential sources suggest that resuspended floor dust is an important contributor to bacterial aerosol populations during occupancy. Experiments that controlled for resuspension from the floor implies that direct human shedding may also significantly impact the concentration of indoor airborne particles. The high content of bacteria specific to the skin, nostrils, and hair of humans found in indoor air and in floor dust indicates that floors are an important reservoir of human-associated bacteria, and that the direct particle shedding of desquamated skin cells and their subsequent resuspension strongly influenced the airborne bacteria population structure in this human-occupied environment. Inhalation exposure to microbes shed by other current or previous human occupants may occur in communal indoor environments. PMID:22529946
Jung, Hae-Jin; Kim, BoWha; Malek, Md Abdul; Koo, Yong Sung; Jung, Jong Hoon; Son, Youn-Suk; Kim, Jo-Chun; Kim, HyeKyoung; Ro, Chul-Un
2012-04-30
Previous studies have reported the major chemical species of underground subway particles to be Fe-containing species that are generated from wear and friction processes at rail-wheel-brake and catenaries-pantographs interfaces. To examine chemical composition of Fe-containing particles in more details, floor dusts were collected at five sampling locations of an underground subway station. Size-segregated floor dusts were separated into magnetic and non-magnetic fractions using a permanent magnet. Using X-ray diffraction (XRD) and scanning electron microscopy/energy dispersive X-ray spectrometry (SEM/EDX), iron metal, which is relatively harmless, was found to be the dominating chemical species in the floor dusts of the <25 μm size fractions with minor fractions of Mg, Al, Si, Ca, S, and C. From SEM analysis, the floor dusts of the <25 μm size fractions collected on railroad ties appeared to be smaller than 10 μm, indicating that their characteristics should somewhat reflect the characteristics of airborne particles in the tunnel and the platform. As most floor dusts are magnetic, PM levels at underground subway stations can be controlled by removing magnetic indoor particles using magnets. In addition, airborne subway particles, most of which were smaller than 10 μm, were collected using permanent magnets at two underground subway stations, namely Jegi and Yangjae stations, in Seoul, Korea. XRD and SEM/EDX analyses showed that most of the magnetic aerosol particles collected at Jegi station was iron metal, whereas those at Yangjae station contained a small amount of Fe mixed with Na, Mg, Al, Si, S, Ca, and C. The difference in composition of the Fe-containing particles between the two subway stations was attributed to the different ballast tracks used. Copyright © 2012 Elsevier B.V. All rights reserved.
Fungi in carpeting and furniture dust.
Schober, G
1991-11-01
The qualitative and quantitative species composition of fungi in carpets and upholstered furniture dust found in the living-rooms of nine Dutch dwellings was examined in a pilot study. Numbers of spores of xerophilic fungi did not differ in dust removed from carpeting and upholstery. Spores of hydrophilic species were found to be more predominant on floors (P less than 0.05), whereas meso-hygrophilic spores, largely dominated by allergologically relevant Penicillium species, were significantly more abundant in dust taken from regularly used furniture (P less than 0.05). Our results indicate that growth conditions for fungi in the micro-habitats of furniture differ from those in carpeting. No statistically significant differences in number of viable spores have been found in samples taken from ground-floor level compared with those taken from 1st to 3rd floor level of dwellings. From this study, the need for a micro-topographic analysis of the fungal flora in the human environment has become apparent. Efficient allergological home sanitation in dwellings of allergic patients requires detailed data about the colonization of the various micro-habitats by allergenic fungi.
NASA Technical Reports Server (NTRS)
Kent, J. J.; Berger, E. L.; Fries, M. D.; Bastien, R.; McCubbin, F. M.; Pace, L.; Righter, K.; Sutter, B.; Zeigler, R. A.; Zolensky, M.
2017-01-01
On the early morning of September 15th, 2016, on the first floor of Building 31 at NASA-Johnson Space Center, the hose from a water chiller ruptured and began spraying water onto the floor. The water had been circulating though old metal pipes, and the leaked water contained rust-colored particulates. The water flooded much of the western wing of the building's ground floor before the leak was stopped, and it left behind a residue of rust across the floor, most notably in the Apollo and Meteorite Thin Section Labs and Sample Preparation Lab. No samples were damaged in the event, and the affected facilities are in the process of remediation. At the beginning of 2016, a separate leak occurred in the Cosmic Dust Lab, located in the same building. In that lab, a water leak occurred at the bottom of the sink used to clean the lab's tools and containers with ultra-pure water. Over years of use, the ultra-pure water eroded the metal sink piping and leaked water onto the inside of the lab's flow bench. This water also left behind a film of rusty material. The material was cleaned up and the metal piping was replaced with PVC pipe and sealed with Teflon plumber's tape. Samples of the rust detritus were collected from both incidents. These samples were imaged and analyzed to determine their chemical and mineralogical compositions. The purpose of these analyses is to document the nature of the detritus for future reference in the unlikely event that these materials occur as contaminants in the Cosmic Dust samples or Apollo or Meteorite thin sections.
Ma, Jing; Addink, Rudolf; Yun, Sehun; Cheng, Jinping; Wang, Wenhua; Kannan, Kurunthachalam
2009-10-01
The formation and release of polybrominated dibenzo-p-dioxins and dibenzofurans (PBDD/Fs) from the incineration of electronic wastes (e-waste) that contain brominated flame retardants (BFRs) are a concern. However, studies on the determination of PBDD/Fs in environmental samples collected from e-waste recycling facilities are scarce. In this study, 11 2,3,7,8-substituted PBDD/Fs and 10 polybrominated diphenyl ether (PBDE) congeners were determined in electronic shredder waste, workshop-floor dust soil, and leaves (of plants on the grounds of the facility) from a large-scale e-waste recycling facility and in surface soil from a chemical-industrial complex (comprising a coke-oven plant, a coal-fired power plant, and a chlor-alkali plant) as well as agricultural areas in eastern China. Total PBDD/F concentrations in environmental samples were in the range of 113-818 pg/g dry wt (dw) for leaves, 392-18500 pg/g dw for electronic shredder residues, 716-800000 pg/g dw for soil samples, and 89600-pg/g dw for workshop-floor dust from the e-waste recycling facility and in a range from nondetect (ND) to 427 pg/g dw in soil from the chemical-industrial complex. The highest mean concentrations of total PBDD/Fs were found in soil samples and workshop-floor dust from the e-waste recycling facility. The dioxin-like toxic equivalent (measured as TEQ) concentrations of PBDD/Fs were greater than the TEQs of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) reported in our previous study for the same set of samples. The concentrations of PBDFs were several orders of magnitude higher than the concentrations of PBDDs in samples from the e-waste facility or from soil from the chemical-industrial complex. A significant correlation was found between the concentrations of sigmaPBDD/Fs and sigmaPBDEs (r = 0.769, p < 0.01) and between sigmaPBDD/Fs and the previously reported sigmaPCDD/F concentrations (r = 0.805, p < 0.01). The estimated daily human intakes of TEQs contributed by PBDD/Fs via soil/dust ingestion and dermal exposures in e-waste recycling facilities were higher than the intakes of TEQs contributed by PCDD/ Fs, calculated in our previous study.
Residential Mercury Contamination in Adobe Brick Homes in Huancavelica, Peru
Hagan, Nicole; Robins, Nicholas; Hsu-Kim, Heileen; Halabi, Susan; Espinoza Gonzales, Ruben Dario; Richter, Daniel deB.; Vandenberg, John
2013-01-01
This is the first study of adobe brick contamination anywhere in the world. Huancavelica, Peru is the site of historic cinnabar refining and one of the most mercury (Hg) contaminated urban areas in the world. Over 80% of homes in Huancavelica are constructed with adobe bricks made from Hg contaminated soil. In this study we measured total Hg concentrations in adobe brick, dirt floor, surface dust, and air samples from the interior of 60 adobe brick houses located in four neighborhoods. Concentrations of total Hg in adobe bricks, dirt floors, and surface dust ranged from 8.00 to 1070 µg/g, 3.06 to 926 µg/g, and 0.02 to 9.69 µg/wipe, respectively, with statistically significant differences between the four neighborhoods. Concentrations of Hg in adobe brick and dirt floor samples in Huancavelica were orders of magnitude higher than in Ayacucho, a non-mining town in Peru. A strong correlation exists between total Hg concentrations in adobe bricks and dirt floors which confirms that adobe bricks were being made on-site and not purchased from an off-site source. A strong correlation between surface dust and adobe bricks and dirt floors indicates that walls and floors serve as indoor sources of Hg contamination. Elemental Hg vapor concentrations were below detection (<0.5 µg/m3) in most homes; however in homes with detectable levels, concentrations up to 5.1 µg/m3 were observed. No statistically significant differences in Hg vapor measurements were observed between neighborhoods. This study demonstrates that building materials used widely in developing communities, such as adobe bricks, may be a substantial source of residential Hg exposure in silver or gold refining communities where Hg is produced or used for amalgamation in artisanal gold production. PMID:24040399
Nishioka, M G; Lewis, R G; Brinkman, M C; Burkholder, H M; Hines, C E; Menkedick, J R
2001-01-01
We collected indoor air, surface wipes (floors, table tops, and window sills), and floor dust samples at multiple locations within 11 occupied and two unoccupied homes both before and after lawn application of the herbicide 2,4-D. We measured residues 1 week before and after application. We used collected samples to determine transport routes of 2,4-D from the lawn into the homes, its subsequent distribution between the indoor surfaces, and air concentration as a function of airborne particle size. We used residue measurements to estimate potential exposures within these homes. After lawn application, 2,4-D was detected in indoor air and on all surfaces throughout all homes. Track-in by an active dog and by the homeowner applicator were the most significant factors for intrusion. Resuspension of floor dust was the major source of 2,4-D in indoor air, with highest levels of 2,4-D found in the particle size range of 2.5-10 microm. Resuspended floor dust was also a major source of 2,4-D on tables and window sills. Estimated postapplication indoor exposure levels for young children from nondietary ingestion may be 1-10 microg/day from contact with floors, and 0.2-30 microg/day from contact with table tops. These are estimated to be about 10 times higher than the preapplication exposures. By comparison, dietary ingestion of 2,4-D is approximately 1.3 microg/day. PMID:11713005
Rudel, Ruthann A; Seryak, Liesel M; Brody, Julia G
2008-01-01
Background Polychlorinated biphenyls (PCBs) are persistent pollutants identified worldwide as human blood and breast milk contaminants. Because they bioaccumulate, consumption of meat, fish, and dairy products predicts human blood concentrations. PCBs were also used widely in building materials, including caulks and paints, but few studies have evaluated the contribution of these exposures to body burden. Methods In an earlier study, we detected PCBs in indoor air in 31% of 120 homes on Cape Cod, MA. Two of the homes had much higher concentrations than the rest, so we retested to verify the initial finding, evaluate blood PCB concentrations of residents, and identify the PCB source. Results Air and dust concentrations remained elevated over 5 years between initial and follow-up sampling. Blood serum concentrations of PCBs in residents of the homes were generally elevated above the 95th percentile of a representative sample of the US population. Serum concentrations in residents and air and dust concentrations were especially high in a home where a resident reported use of PCB-containing floor finish in the past, and where the floor of one room was sanded and refinished just prior to sample collection. Conclusion This case-study suggests that PCB residues in homes may be more significant contributors to overall exposure than diet for some people, and that use of a commercially-available PCB-containing wood floor finish in residences during the 1950s and 1960s is an overlooked but potentially important source of current PCB exposure in the general population. PMID:18201376
Barone, T L; Patts, J R; Janisko, S J; Colinet, J F; Patts, L D; Beck, T W; Mischler, S E
2016-01-01
Airborne coal dust mass measurements in underground bituminous coal mines can be challenged by the presence of airborne limestone dust, which is an incombustible dust applied to prevent the propagation of dust explosions. To accurately measure the coal portion of this mixed airborne dust, the National Institute for Occupational Safety and Health (NIOSH) developed a sampling and analysis protocol that used a stainless steel cassette adapted with an isokinetic inlet and the low temperature ashing (LTA) analytical method. The Mine Safety and Health Administration (MSHA) routinely utilizes this LTA method to quantify the incombustible content of bulk dust samples collected from the roof, floor, and ribs of mining entries. The use of the stainless steel cassette with isokinetic inlet allowed NIOSH to adopt the LTA method for the analysis of airborne dust samples. Mixtures of known coal and limestone dust masses were prepared in the laboratory, loaded into the stainless steel cassettes, and analyzed to assess the accuracy of this method. Coal dust mass measurements differed from predicted values by an average of 0.5%, 0.2%, and 0.1% for samples containing 20%, 91%, and 95% limestone dust, respectively. The ability of this method to accurately quantify the laboratory samples confirmed the validity of this method and allowed NIOSH to successfully measure the coal fraction of airborne dust samples collected in an underground coal mine.
Barone, T. L.; Patts, J. R.; Janisko, S. J.; Colinet, J. F.; Patts, L. D.; Beck, T. W.; Mischler, S. E.
2016-01-01
Airborne coal dust mass measurements in underground bituminous coal mines can be challenged by the presence of airborne limestone dust, which is an incombustible dust applied to prevent the propagation of dust explosions. To accurately measure the coal portion of this mixed airborne dust, the National Institute for Occupational Safety and Health (NIOSH) developed a sampling and analysis protocol that used a stainless steel cassette adapted with an isokinetic inlet and the low temperature ashing (LTA) analytical method. The Mine Safety and Health Administration (MSHA) routinely utilizes this LTA method to quantify the incombustible content of bulk dust samples collected from the roof, floor, and ribs of mining entries. The use of the stainless steel cassette with isokinetic inlet allowed NIOSH to adopt the LTA method for the analysis of airborne dust samples. Mixtures of known coal and limestone dust masses were prepared in the laboratory, loaded into the stainless steel cassettes, and analyzed to assess the accuracy of this method. Coal dust mass measurements differed from predicted values by an average of 0.5%, 0.2%, and 0.1% for samples containing 20%, 91%, and 95% limestone dust, respectively. The ability of this method to accurately quantify the laboratory samples confirmed the validity of this method and allowed NIOSH to successfully measure the coal fraction of airborne dust samples collected in an underground coal mine. PMID:26618374
Silica dust exposures during selected construction activities.
Flanagan, Mary Ellen; Seixas, Noah; Majar, Maria; Camp, Janice; Morgan, Michael
2003-01-01
This study characterized exposure for dust-producing construction tasks. Eight common construction tasks were evaluated for quartz and respirable dust exposure by collecting 113 personal task period samples for cleanup; demolition with handheld tools; concrete cutting; concrete mixing; tuck-point grinding; surface grinding; sacking and patching concrete; and concrete floor sanding using both time-integrating filter samples and direct-reading respirable dust monitors. The geometric mean quartz concentration was 0.10 mg/m(3) (geometric standard deviation [GSD]=4.88) for all run time samples, with 71% exceeding the threshold limit value. Activities with the highest exposures were surface grinding, tuck-point grinding, and concrete demolition (GM[GSD] of 0.63[4.12], 0.22[1.94], and 0.10[2.60], respectively). Factors recorded each minute were task, tool, work area, respiratory protection and controls used, estimated cross draft, and whether anyone nearby was making dust. Factors important to exposure included tool used, work area configuration, controls employed, cross draft, and in some cases nearby dust. More protective respirators were employed as quartz concentration increased, although respiratory protection was found to be inadequate for 42% of exposures. Controls were employed for only 12% of samples. Exposures were reduced with three controls: box fan for surface grinding and floor sanding, and vacuum/shroud for surface grinding, with reductions of 57, 50, and 71%, respectively. Exposures were higher for sweeping compound, box fan for cleanup, ducted fan dilution, and wetted substrate. Construction masons and laborers are frequently overexposed to silica. The usual protection method, respirators, was not always adequate, and engineering control use was infrequent and often ineffective.
Davies, R H; Wray, C
1996-05-01
A study of the dissemination of Salmonella enteritidis in the poultry breeder industry in the UK showed that the choice of sites for sampling the environment of occupied houses and empty houses which had been disinfected after depopulation had a significant influence on the outcome. Increased isolation rates could be achieved by sampling nest box floors and dust in open slave feed hoppers in occupied poultry houses. Nest box floors were the most sensitive sites for detection of residual environmental contamination in poultry houses where enrofloxacin treatment had been used. Floor sweepings, nest box floors, slave feed hoppers, hydrated wall fabric junctions and high beams and pipes were the most sensitive sample sites in cleansed and disinfected poultry houses. The use of universal disinfectant neutralisers gave good results in laboratory trials but appeared to reduce the isolation rate from field samples.
Repeated measurements of mite and pet allergen levels in house dust over a time period of 8 years.
Antens, C J M; Oldenwening, M; Wolse, A; Gehring, U; Smit, H A; Aalberse, R C; Kerkhof, M; Gerritsen, J; de Jongste, J C; Brunekreef, B
2006-12-01
Studies of the association between indoor allergen exposure and the development of allergic diseases have often measured allergen exposure at one point in time. We investigated the variability of house dust mite (Der p 1, Der f 1) and cat (Fel d 1) allergen in Dutch homes over a period of 8 years. Data were obtained in the Dutch PIAMA birth cohort study. Dust from the child's mattress, the parents' mattress and the living room floor was collected at four points in time, when the child was 3 months, 4, 6 and 8 years old. Dust samples were analysed for Der p 1, Der f 1 and Fel d 1 by sandwich enzyme immuno assay. Mite allergen concentrations for the child's mattress, the parents' mattress and the living room floor were moderately correlated between time-points. Agreement was better for cat allergen. For Der p 1 and Der f 1 on the child's mattress, the within-home variance was close to or smaller than the between-home variance in most cases. For Fel d 1, the within-home variance was almost always smaller than the between-home variance. Results were similar for allergen levels expressed per gram of dust and allergen levels expressed per square metre of the sampled surface. Variance ratios were smaller when samples were taken at shorter time intervals than at longer time intervals. Over a period of 4 years, mite and cat allergens measured in house dust are sufficiently stable to use single measurements with confidence in epidemiological studies. The within-home variance was larger when samples were taken 8 years apart so that over such long periods, repetition of sampling is recommended.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Allgood, Jaime M.; Jimah, Tamara
Most households and workplaces all over the world possess furnishings and electronics, all of which contain potentially toxic flame retardant chemicals to prevent fire hazards. Indoor dust is a recognized repository of these types of chemicals including polybrominated diphenyl ethers (PBDEs) and non-polybrominated diphenyl ethers (non-PBDEs). However, no previous U.S. studies have differentiated concentrations from elevated surface dust (ESD) and floor dust (FD) within and across microenvironments. We address this information gap by measuring twenty-two flame-retardant chemicals in dust on elevated surfaces (ESD; n=10) and floors (FD; n=10) from rooms on a California campus that contain various concentrations of electronicmore » products. We hypothesized a difference in chemical concentrations in ESD and FD. Secondarily, we examined whether or not this difference persisted: (a) across the studied microenvironments and (b) in rooms with various concentrations of electronics. A Wilcoxon signed-rank test demonstrated that the ESD was statistically significantly higher than FD for BDE-47 (p=0.01), BDE-99 (p=0.01), BDE-100 (p=0.01), BDE-153 (p=0.02), BDE-154 (p=0.02), and 3 non-PBDEs including EH-TBB (p=0.02), BEH-TEBP (p=0.05), and TDCIPP (p=0.03). These results suggest different levels and kinds of exposures to flame-retardant chemicals for individuals spending time in the sampled locations depending on the position of accumulated dust. Therefore, further research is needed to estimate human exposure to flame retardant chemicals based on how much time and where in the room individuals spend their time. Such sub-location estimates will likely differ from assessments that assume continuous unidimensional exposure, with implications for improved understanding of potential health impacts of flame retardant chemicals. - Highlights: • Brominated flame retardants used in electronic products accumulate in room dust • Various chemical moieties of flame retardants leach differently into room dust • Flame retardant concentrations in dust differ in elevated surfaces compared to floors.« less
Indoor air, surface wipes (floors, table tops and window sills) and floor dust samples were collected at multiple locations within 11 occupied and 2 unoccupied homes both prior to and following lawn application of the herbicide 2,4-D. Residue measurements were made over period...
Arbes, Samuel J; Sever, Michelle; Vaughn, Ben; Mehta, Jigna; Lynch, Jeffrey T; Mitchell, Herman; Hoppin, Jane A; Spencer, Harvey L; Sandler, Dale P; Zeldin, Darryl C
2005-06-01
Studies of indoor allergen exposures are often limited by the cost and logistics of sending technicians to homes to collect dust. In this study we evaluated the feasibility of having subjects collect their own dust samples. The objectives were to compare allergen concentrations between subject- and technician-collected samples and to examine the sample return rate. Using a dust collection device and written instructions provided to them by mail, 102 subjects collected a combined dust sample from a bed and bedroom floor. Later the same day, a technician collected a side-by-side sample. Dust samples were weighed and analyzed for the cat allergen Fel d 1 and the dust mite allergen Der p 1. Fifty additional subjects who were enrolled by telephone were mailed dust collection packages and asked to return a dust sample and questionnaire by mail. A technician did not visit their homes. Correlations between subject- and technician-collected samples were strong for concentrations of Fel d 1 (r = 0.88) and Der p 1 (r = 0.87). With allergen concentrations dichotomized at lower limits of detection and clinically relevant thresholds, agreements between methodologies ranged from 91 to 98%. Although dust weights were correlated (r = 0.48, p < 0.001), subjects collected lighter samples. Among the group of 50 subjects, 46 returned a dust sample and completed questionnaire. The median number of days to receive a sample was 15. With some limitations, subject-collected dust sampling appears to be a valid and practical option for epidemiologic and clinical studies that report allergen concentration as a measure of exposure.
The effect of sub-floor heating on house-dust-mite populations on floors and in furniture.
de Boer, Rob
2003-01-01
It is well known that dehydrating conditions for house dust mites can be created by simply raising the temperature, causing loss of body water and eventually death. Thus, it can be expected that conditions for dust mites are less favourable on floors supplied with sub-floor heating. This was examined in a study of 16 houses with sub-floor heating and 21 without. The pattern of changes in air humidity and temperature on the floors was investigated and compared to known data of the tolerance of dust mites. Also the resident mite populations were compared. Floors with sub-floor heating had, on average, fewer mites, but the difference with unheated floors was small. It was remarkable that mite numbers were also lower in upholstered furniture. Another important observation was that some houses with sub-floor heating had high mite numbers, indicating that this type of heating is compatible with a thriving mite population. Temperature and humidity conditions of heated floors may allow mites not only to survive, but also to remain active in winter. A moderate increase in temperature, a moderate decrease in (absolute) air humidity, or a combination of both, will suffice to keep the humidity all winter below the Critical Equilibrium Humidity, the level of air humidity that is critical for mite growth and reproduction, hence for allergen production. However, it is argued that measures to suppress allergen production by house dust mites are likely to be far more effective if taken in summer rather than in winter.
Wood Dust Sampling: Field Evaluation of Personal Samplers When Large Particles Are Present
Lee, Taekhee; Harper, Martin; Slaven, James E.; Lee, Kiyoung; Rando, Roy J.; Maples, Elizabeth H.
2011-01-01
Recent recommendations for wood dust sampling include sampling according to the inhalable convention of International Organization for Standardization (ISO) 7708 (1995) Air quality—particle size fraction definitions for health-related sampling. However, a specific sampling device is not mandated, and while several samplers have laboratory performance approaching theoretical for an ‘inhalable’ sampler, the best choice of sampler for wood dust is not clear. A side-by-side field study was considered the most practical test of samplers as laboratory performance tests consider overall performance based on a wider range of particle sizes than are commonly encountered in the wood products industry. Seven companies in the wood products industry of the Southeast USA (MS, KY, AL, and WV) participated in this study. The products included hardwood flooring, engineered hardwood flooring, door skins, shutter blinds, kitchen cabinets, plywood, and veneer. The samplers selected were 37-mm closed-face cassette with ACCU-CAP™, Button, CIP10-I, GSP, and Institute of Occupational Medicine. Approximately 30 of each possible pairwise combination of samplers were collected as personal sample sets. Paired samplers of the same type were used to calculate environmental variance that was then used to determine the number of pairs of samples necessary to detect any difference at a specified level of confidence. Total valid sample number was 888 (444 valid pairs). The mass concentration of wood dust ranged from 0.02 to 195 mg m−3. Geometric mean (geometric standard deviation) and arithmetic mean (standard deviation) of wood dust were 0.98 mg m−3 (3.06) and 2.12 mg m−3 (7.74), respectively. One percent of the samples exceeded 15 mg m−3, 6% exceeded 5 mg m−3, and 48% exceeded 1 mg m−3. The number of collected pairs is generally appropriate to detect a 35% difference when outliers (negative mass loadings) are removed. Statistical evaluation of the nonsimilar sampler pair results produced a finding of no significant difference between any pairing of sampler type. A practical consideration for sampling in the USA is that the ACCU-CAP™ is similar to the sampler currently used by the Occupational Safety and Health Administration for purposes of demonstrating compliance with its permissible exposure limit for wood dust, which is the same as for Particles Not Otherwise Regulated, also known as inert dust or nuisance dust (Method PV2121). PMID:21036895
Assessment of fungal diversity in a water-damaged office building.
Green, Brett J; Lemons, Angela R; Park, Yeonmi; Cox-Ganser, Jean M; Park, Ju-Hyeong
2017-04-01
Recent studies have described fungal communities in indoor environments using gene sequencing-based approaches. In this study, dust-borne fungal communities were elucidated from a water-damaged office building located in the northeastern region of the United States using internal transcribed spacer (ITS) rRNA gene sequencing. Genomic DNA was extracted from 5 mg of floor dust derived from 22 samples collected from either the lower floors (n = 8) or a top floor (n = 14) of the office building. ITS gene sequencing resolved a total of 933 ITS sequences and was clustered into 216 fungal operational taxonomic units (OTUs). Analysis of fungal OTUs at the 97% similarity threshold showed a difference between the lower and top floors that was marginally significant (p = 0.049). Species richness and diversity indices were reduced in the lower floor samples compared to the top floor samples and there was a high degree of compositional dissimilarity within and between the two different areas within the building. Fungal OTUs were placed in the phyla Ascomycota (55%), Basidiomycota (41%), Zygomycota (3%), Glomeromycota (0.4%), Chytridiomycota (0.3%), and unassigned fungi (0.5%). The Ascomycota classes with the highest relative abundances included the Dothideomycetes (30%) and Eurotiomycetes (16%). The Basidiomycota consisted of the classes Ustilaginomycetes (14%), Tremellomycetes (11%), and Agaricomycetes (8%). Sequence reads derived from the plant pathogen Ustilago syntherismae were the most abundant in the analysis as were obligate Basidiomycota yeast species that accounted for 12% and 11% of fungal ITS sequences, respectively. ITS gene sequencing provides additional insight into the diversity of fungal OTUs. These data further highlight the contribution of fungi placed in the phylum Basidiomycota, obligate yeasts, as well as xerophilic species that are typically not resolved using traditional culture methods.
PAH EXPOSURES OF NINE PRESCHOOL CHILDREN
The exposures to 20 polycyclic aromatic hydrocarbons (PAH) of 9 children, ages 2-5 yr, were measured over 48 hr at day care and at home. Sampled media included indoor and outdoor air, floor dust, outdoor play area soil, hand surface, and solid and liquid food. Urine samples ...
Rauert, C; Harrad, S; Suzuki, G; Takigami, H; Uchida, N; Takata, K
2014-09-15
Brominated flame retardants (BFRs) have been detected in indoor dust in many studies, at concentrations spanning several orders of magnitude. Limited information is available on the pathways via which BFRs migrate from treated products into dust, yet the different mechanisms hypothesized to date may provide an explanation for the range of reported concentrations. In particular, transfer of BFRs to dust via abrasion of particles or fibers from treated products may explain elevated concentrations (up to 210 mg g(-1)) of low volatility BFRs like decabromodiphenyl ether (BDE-209). In this study, an indoor dust sample containing a low concentration of hexabromocyclododecane, or HBCD, (110 ng g(-1) ΣHBCDs) was placed on the floor of an in-house test chamber. A fabric curtain treated with HBCDs was placed on a mesh shelf 3 cm above the chamber floor and abrasion induced using a stirrer bar. This induced abrasion generated fibers of the curtain, which contaminated the dust, and ΣHBCD concentrations in the dust increased to between 4020 and 52 500 ng g(-1) for four different abrasion experiment times. The highly contaminated dust (ΣHBCD at 52 500 ng g(-1)) together with three archived dust samples from various UK microenvironments, were investigated with forensic microscopy techniques. These techniques included Micro X-ray fluorescent spectroscopy, scanning emission microscopy coupled with an energy dispersive X-ray spectrometer, Fourier transform infrared spectroscopy with further BFR analysis on LC-MS/MS. Using these techniques, fibers or particles abraded from a product treated with BFRs were identified in all dust samples, thereby accounting for the elevated concentrations detected in the original dust (3500 to 88 800 ng g(-1) ΣHBCD and 24 000 to 1,438 000 ng g(-1) for BDE-209). This study shows how test chamber experiments alongside forensic microscopy techniques, can provide valuable insights into the pathways via which BFRs contaminate indoor dust. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Zhang, Qi; Lu, Xiao-Mei; Zhang, Xiao-Ling; Sun, Yong-Gang; Zhu, Dong-Mei; Wang, Bing-Ling; Zhao, Ren-Zheng; Zhang, Zheng-Dong
2013-04-01
To investigate the levels and possible determinants of phthalate esters (PEs) in settled house dust from urban dwellings with young children, dust was collected from 215 urban houses in Nanjing, China, and 145 outdoor settled dust samples were collected nearby. Six PEs were measured by gas chromatography/mass spectrometry. All PEs were detected in the dust from approximately 90% of the houses, with the exception of dioctyl phthalate (DOP), which had only a 59% detection rate. Di-2-ethylhexyl phthalate (DEHP) and di-n-butyl phthalate (DBP) were the most abundant PEs, with geometric means of 110 and 16.4 μg g-1, respectively, and maximal concentrations 9950 and 2150 μg g-1. Factor analysis showed that DBP, DEHP and benzyl butyl phthalate (BBP) might come from the same source and were significantly influenced by the use of solid-wood floor wax. High BBP, DEHP, DOP and total PE levels were associated with indices of dampness, and high DOP was associated with humidifier use. In conclusion, six PEs are ubiquitous in urban settled house dust in Nanjing, China, and both plastic materials and cosmetic and personal care products are important sources. Flooring material, dampness and humidifier use potentially influence house dust PE levels.
Activation of human peroxisome-activated receptor-gamma ...
Obesity in children has become an epidemic and recent research suggests a possible contribution from exposure to environmental chemicals. Several chemicals, such as phthalates, brominated flame retardants, and perfluorinated chemicals, are common in house dust on floors where children play and are suspected obesogens. Obesogens can act via a mechanism that involves activation of peroxisome proliferator-activated receptor-gamma (PPARy). A previous study found that dust collected from children’s homes binds to PPARy. Here, we investigated the ability of house dust to activate PPARy in a transiently transfected cell assay. Dust samples were collected in 2012 from carpeted and hardwood floors in children’s homes using thimbles fitted into a vacuum cleaner hose (“TEO” samples), or from homes in an adult cohort NIEHS study. Dust was extracted with 50:50 hexane:acetone, sonicated, centrifuged, and the organic layer collected. This was repeated 2X. The extracts were filtered to remove particulates, dried with purified nitrogen, and reconstituted in DMS0 at 200 ug/ul. COS-1 cells were transfected for 24 hrs with a human PPARy vector containing a luciferase reporter, and exposed for 24 hrs to negative controls water or DMSO (0.1%), positive controls Troglitazone (3 uM in water) or Rosiglitazone (100 nM in DMSO), or dust extracts serially diluted in DMEM at 50, 100, and 200 ug/ml in 0.1% DMSO. Cells were lysed and luciferase activity was measured. Data were log-tra
Allgood, Jaime M; Jimah, Tamara; McClaskey, Carolyn M; La Guardia, Mark J; Hammel, Stephanie C; Zeineddine, Maryam M; Tang, Ian W; Runnerstrom, Miryha G; Ogunseitan, Oladele A
2017-02-01
Most households and workplaces all over the world possess furnishings and electronics, all of which contain potentially toxic flame retardant chemicals to prevent fire hazards. Indoor dust is a recognized repository of these types of chemicals including polybrominated diphenyl ethers (PBDEs) and non-polybrominated diphenyl ethers (non-PBDEs). However, no previous U.S. studies have differentiated concentrations from elevated surface dust (ESD) and floor dust (FD) within and across microenvironments. We address this information gap by measuring twenty-two flame-retardant chemicals in dust on elevated surfaces (ESD; n=10) and floors (FD; n=10) from rooms on a California campus that contain various concentrations of electronic products. We hypothesized a difference in chemical concentrations in ESD and FD. Secondarily, we examined whether or not this difference persisted: (a) across the studied microenvironments and (b) in rooms with various concentrations of electronics. A Wilcoxon signed-rank test demonstrated that the ESD was statistically significantly higher than FD for BDE-47 (p=0.01), BDE-99 (p=0.01), BDE-100 (p=0.01), BDE-153 (p=0.02), BDE-154 (p=0.02), and 3 non-PBDEs including EH-TBB (p=0.02), BEH-TEBP (p=0.05), and TDCIPP (p=0.03). These results suggest different levels and kinds of exposures to flame-retardant chemicals for individuals spending time in the sampled locations depending on the position of accumulated dust. Therefore, further research is needed to estimate human exposure to flame retardant chemicals based on how much time and where in the room individuals spend their time. Such sub-location estimates will likely differ from assessments that assume continuous unidimensional exposure, with implications for improved understanding of potential health impacts of flame retardant chemicals. Copyright © 2016 Elsevier Inc. All rights reserved.
Muenhor, Dudsadee; Moon, Hyo-Bang; Lee, Sunggyu; Goosey, Emma
2017-12-06
This study characterizes concentrations of polybrominated diphenyl ethers (PBDEs) in floor and road dust from a manual e-waste dismantling facility and adjacent communities in Thailand. Levels of Σ22 PBDEs in floor dust from the facility varied between 1,200 and 43,000 ng g -1 , whereas those from adjacent communities were in the range 6.6-2,200 ng g -1 . Concentrations of Σ22 PBDEs (43,000 ng g -1 ) were highest in floor dust collected from the facility. Levels of Σ22 PBDEs and all congeners studied, except for BDE-66, BDE-71, BDE-85, BDE-119, BDE-138, BDE-190 and BDE-191 in facility dust were significantly greater than those in residential dust (P = <0.001-0.017). Moreover, PBDE contents decreased with increasing distance from the facility, revealing that the facility may represent a principal source of PBDEs to the surrounding environment. Levels of Σ22 PBDEs in road dust from the facility varied from 27 to 21,000 ng g -1 , while those from the adjacent residences were about 5.4-63 ng g -1 . Concentrations of Σ22 PBDEs (21,000 ng g -1 ) were highest in road dust taken at the facility. The PBDE congener profile for floor dust from the facility was dominated by BDEs 28, 47 and 209, whereas domestic floor dust was predominated by BDEs 206 and 209. Under various scenarios of occupational and environmental exposure to BDE-99 and BDE-209, workers in the facility as well as adults and children in the adjacent communities were exposed below the United States Environmental Protection Agency (US EPA)'s reference doses (RfDs) for BDE-99 (100 ng/kg bw/day) and BDE-209 (7,000 ng/kg bw/day).
Swaddiwudhipong, Witaya; Tontiwattanasap, Worawit; Khunyotying, Wanlee; Sanreun, Cherd
2013-11-01
We evaluate blood lead levels among Thai children to determine if exposure to lead-acid batteries is associated with elevated blood lead levels (EBLL). We screened 254 children aged 1-14 years old from 2 rural Thai villages for blood lead levels. We also screened 18 of 92 houses in these 2 villages for the presence of environmental lead. The overall prevalence of EBLL (> or = 10 microg/dl) was 43.3% and the mean lead level among study subjects was 9.8 +/- 5.1 microg/dl. The blood lead levels significantly decreased with increasing age. Fifty point eight percent of children who lived in a house with vented lead-acid batteries had EBLL while 23.3% of children who lived in a house without vented lead-acid batteries had EBLL. Multiple logistic regression analysis revealed a significant positive association between the presence of vented lead-acid batteries and EBLL, after adjusting for other variables. Forty-two point nine percent of house floor dust samples collected near the batteries had elevated lead levels, 7.1% of house floor dust samples collected from other areas in the house had elevated lead levels and 0% of the house floor dust samples collected in houses without vented lead-acid batteries had elevated lead levels. In the sampled houses with vented lead-acid batteries, lead contamination was found in the drinking-water kept in household containers, but not in the tap water or other village sources of water. Improper care and placement of vented lead-acid batteries can result in lead contamination in the home environment causing EBLL in exposed children.
Wu, Q; Baek, S-Y; Fang, M; Chang, Y-S
2010-06-01
Polybrominated diphenyl ethers (PBDEs) are considered harmful to human health because of their toxicities and persistence in environments. In the current study, the distribution and fate of PBDEs in classrooms and computer rooms in 17 elementary schools in South Korea have been described. Eight congeners (brominated diphenyl ether-28, -47, -99, -100, -153, -154, -183, and -209) in air, floor dust, and product surface dust were measured. While Sigma(8)PBDEs in the air in classrooms showed considerable variations (0.659-1600 pg/m(3), arithmetic mean +/- s.d.: 377 +/- 441 pg/m(3)), those in computer rooms were somewhat similar (134-220 pg/m(3), arithmetic mean +/- s.d.: 169 +/- 40 pg/m(3)). Sigma(8)PBDEs in floor dust varied over a wide range, from 453 to 45,700 ng/g, for all rooms. Based on congener patterns, two groups were created--CL-1 that is dominated by high-brominated congeners and CL-2 primarily comprising low-brominated congeners--for both air and floor dust of classrooms. Surface dust had low concentrations, ranged from ND to 181, from ND to 128, and from ND to 256 pg/cm(2) for desk/chair sets, lockers, and playing tools, respectively. Pearson correlation coefficients were calculated individually for air, floor dust, and surface dust. The results indicate that both surface dust and floor dust may act as a secondary source of PBDEs in indoor environments after emission from facilities. Children have been estimated to have a higher potential exposure to PBDEs than adults. Since children spend most of their day time at school, PBDE distributions in school environments should be a matter of great concern.
Lau, Winifred Ka Yan; Liang, Peng; Man, Yu Bon; Chung, Shan Shan; Wong, Ming Hung
2014-03-01
This study investigated health risks exerted on electronic waste (e-waste) recycling workers exposed to cadmium (Cd), chromium (Cr), copper (Cu), lead (Pb), nickel (Ni), mercury (Hg), and zinc (Zn) in Hong Kong. E-waste recycling workshops were classified into eight working areas: 1 = office, 2 = repair, 3 = dismantling, 4 = storage, 5 = desoldering, 6 = loading, 7 = cable shredding, and 8 = chemical waste. The aforementioned metal concentrations were analyzed in suspended air particulates, surface dust and floor dust collected from the above study areas in five workshops. Elevated Pb levels were measured in dismantling and desoldering areas (582 and 486 μg/100 cm(2) in surface and 3,610 and 19,172 mg/kg in floor dust, respectively). Blood lead levels of 10 and 39.5 μg/dl were estimated using United States Environmental Protection Agency's Adult Lead Model as a result of exposure to the floor dust from these two areas. Human health risk assessments were conducted to evaluate cancer and noncancer risks resulting from exposure to floor dust through the combined pathways of ingestion, dermal contact, and inhalation. Findings indicated that workers may be exposed to cancer risks above the acceptable range at 147 in a million at the 95th percentile in the dismantling area. Workers should be informed of associated risks to safeguard their health.
Cat allergen levels in public places in New Zealand.
Martin, I R; Wickens, K; Patchett, K; Kent, R; Fitzharris, P; Siebers, R; Lewis, S; Crane, J; Holbrook, N; Town, G I; Smith, S
1998-09-25
Cat allergen (Fel d 1) is a known risk factor for asthma. Studies have demonstrated Fel d 1 in both public buildings and domestic dwellings where cats have never been. The aims of this study were to measure reservoir Fel d 1 levels in public buildings in New Zealand, to examine determinants of these levels and to compare them with previously measured domestic levels. Dust was obtained in two centres (Wellington and Christchurch) from hotels, hospitals, rest homes, churches, primary schools, childcare centres, cinemas, bank head offices and aeroplanes; and from North Island ski lodges. Measurements of temperature and relative humidity were taken. Information was collected on building characteristics. Fel d 1 levels (microg/g of fine dust) for floors (n=203), beds (n=64) and seats (n=24) were expressed as geometric means (95% confidence intervals). Detectable Fel d 1 levels were found in 95% of floor samples, 91% of bed samples and 100% of seat samples. Fel d 1 levels [geometric mean (95% confidence intervals)] were significantly higher on cinema and domestic aircraft seats [36.8 (20.8-65.3) microg/g and 33.3 (28.0-39.7) microg/g respectively] than on floors [3.6 (2.5-5.1) microg/g and 2.4 (1.8-3.0) microg/g respectively]. Floor Fel d 1 levels in the public buildings sampled were lower than those of domestic dwellings without cats [0.9 (0.6-1.4) microg/g vs 1.7 (1.2-2.4)] microg/g in Wellington and [2.0 (1.6-2.6) microg/g vs 4.0 (2.7-6.0] microg/g in Christchurch. After controlling for potential confounders, floor Fel d 1 levels were higher with carpeted floors (p<0.001) and lower in banks and hospitals (p<0.001). Fel d 1 levels in public buildings are low in New Zealand public places except for cinema and domestic aircraft seats where all but one sample had Fel d 1 levels potentially high enough to precipitate asthma symptoms in sensitised individuals.
Fungi of the house dust in Riyadh, Saudi Arabia.
Saad, R R; el-Gindy, A A
1990-01-01
30 species belonging to 18 genera were isolated from floor dust of 30 homes in Riyadh. Out of them 16 species and 10 genera were isolated from dust of air conditioners of the same homes. The most common genera in floor dust were Aspergillus, Penicillium and Cladosporium. Aspergillus repens, A. amstelodami, A. versicolor, A. fumigatus, Penicillium purpurogenum, P. crustosum, Cladosporium cladosporoides and C. herbarum were frequently isolated. The most abundant genera in air conditioner dust were Aspergillus and Penicillium. Aspergillus fumigatus, A. ochraceus, A. terreus, Penicillium oxalicium and P. crustosum were most frequent species.
Morgan, Marsha K.
2012-01-01
Pyrethroid insecticides are frequently used to control insects in residential and agriculture settings in the United States and worldwide. As a result, children can be potentially exposed to pyrethroid residues in food and at home. This review summarizes data reported in 15 published articles from observational exposure measurement studies conducted from 1999 to present that examined children’s (5 months to 17 years of age) exposures to pyrethroids in media including floor wipes, floor dust, food, air, and/or urine collected at homes in the United States. At least seven different pyrethroids were detected in wipe, dust, solid food, and indoor air samples. Permethrin was the most frequently detected (>50%) pyrethroid in these media, followed by cypermethrin (wipes, dust, and food). 3-phenoxybenzoic acid (3-PBA), a urinary metabolite of several pyrethroids, was the most frequently (≥67%) detected pyrethroid biomarker. Results across studies indicate that these children were likely exposed to several pyrethroids, but primarily to permethrin and cypermethrin, from several sources including food, dust, and/or on surfaces at residences. Dietary ingestion followed by nondietary ingestion were the dominate exposure routes for these children, except in homes with frequent pesticide applications (dermal followed by dietary ingestion). Urinary 3-PBA concentration data confirm that the majority of the children sampled were exposed to one or more pyrethroids. PMID:23066409
RELATIVE MOLDINESS INDEX© AS PREDICTOR OF CHILDHOOD RESPIRATORY ILLNESS
The results of a traditional visual mold inspection were compared to a mold evaluation based on the Relative Moldiness Index (RMI). The RMI is calculated from mold specific quantitative PCR (MSQPCR) measurements of the concentation of 36 species of molds in floor dust samples. ...
Placers of cosmic dust in the blue ice lakes of Greenland
NASA Technical Reports Server (NTRS)
Maurette, M.; Hammer, C.; Reeh, N.; Brownlee, D. E.; Thomsen, H. H.
1986-01-01
A concentration process occurring in the melt zone of the Greenland ice cap has produced the richest known deposit of cosmic dust on the surface of the earth. Extraterrestrial particles collected from this region are well preserved and are collectable in large quantities. The collected particles are generally identical to cosmic spheres found on the ocean floor, but a pure glass type was discovered that has not been seen in deep-sea samples. Iron-rich spheres are conspicuously rare in the collected material.
Bertelsen, R J; Faeste, C K; Granum, B; Egaas, E; London, S J; Carlsen, K-H; Lødrup Carlsen, K C; Løvik, M
2014-01-01
Sensitization to food allergens and food allergic reactions are mostly caused by ingesting the allergen, but can also occur from exposure via the respiratory tract or the skin. Little is known about exposure to food allergens in the home environment. The objective of this study was firstly to describe the frequency of detection of allergens from fish, egg, milk, and peanut in mattress dust collected from homes of 13-year-old adolescents and secondly to identify home characteristics associated with the presence of food allergen contamination in dust. Food allergens were measured by dot blot analysis in mattress dust from 143 homes in Oslo, Norway. We analysed associations between home characteristics (collected by parental questionnaires and study technicians) and food allergens by multivariate regression models. Fish allergen was detected in 46%, peanut in 41%, milk in 39%, and egg allergen in 22% of the mattress dust samples; only three samples contained none of these allergens. All four food allergens were more frequently detected in mattresses in small dwellings (< 100 m(2)) than larger dwellings (≥ 130 m(2)); 63-71% of the small dwellings (n = 24) had milk, peanut, and fish allergens in the samples compared with 33-44% of the larger dwellings (n = 95). Milk, peanut, and egg allergens were more frequently detected in homes with bedroom and kitchen on the same floor as compared with different floors, with odds ratios of 2.5 (95% confidence interval (CI): 1.1, 5.6) for milk, 2.4 (95% CI: 1.0, 6.1) for peanut, and 3.1 (95% CI: 1.3, 7.5) for egg allergens. Food allergens occurred frequently in beds in Norwegian homes, with dwelling size and proximity of kitchen and bedroom as the most important determinants. Due to the amount of time children spent in the bedroom, mattress dust may be an important source of exposure to food allergens. © 2013 John Wiley & Sons Ltd.
Bertelsen, Randi J.; Fæste, Christiane K.; Granum, Berit; Egaas, Eliann; London, Stephanie J.; Carlsen, Kai-Håkon; Carlsen, Karin C. Lødrup; Løvik, Martinus
2014-01-01
Background Sensitization to food allergens and food allergic reactions are mostly caused by ingesting the allergen, but can also occur from exposure via the respiratory tract or the skin. Little is known about exposure to food allergens in the home environment. Objective To describe the frequency of detection of allergens from fish, egg, milk, and peanut in mattress dust collected from homes of 13 year old adolescents, and secondly to identify home characteristics associated with the presence of food allergen contamination in dust. Methods Food allergens were measured by dot blot analysis in mattress dust from 143 homes in Oslo, Norway. We analyzed associations between home characteristics (collected by parental questionnaires and study technicians) and food allergens by multivariate regression models. Results Fish allergen was detected in 46%, peanut in 41%, milk in 39%, and egg allergen in 22% of the mattress dust samples; only three samples contained none of these allergens. All four food allergens were more frequently detected in mattresses in small dwellings (<100m2) than larger dwellings (≥130 m2); 63-71% of the small dwellings (n=24) had milk, peanut, and fish allergens in the samples compared to 33-44% of the larger dwellings (n=95). Milk, peanut, and egg allergens were more frequently detected in homes with bedroom and kitchen on the same floor as compared with different floors; with odds ratios of 2.5 (95% confidence interval (CI): 1.1, 5.6) for milk, 2.4 (95% CI: 1.0, 6.1) for peanut, and 3.1 (95% CI: 1.3, 7.5) for egg allergens. Conclusions and clinical relevance Food allergens occurred frequently in beds in Norwegian homes, with dwelling size and proximity of kitchen and bedroom as the most important determinants. Due to the amount of time children spend in the bedroom, mattress dust may be an important source of exposure to food allergens. PMID:24304208
Systematic on-site monitoring of compliance dust samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grayson, R.L.; Gandy, J.R.
1996-12-31
Maintaining compliance with U.S. respirable coal mine dust standards can be difficult on high-productivity longwall panels. Comprehensive and systematic analysis of compliance dust sample data, coupled with access to the U.S. Bureau of Mines (USBM) DUSTPRO, can yield important information for use in maintaining compliance. The objective of this study was to develop and apply a customized software for the collection, storage, modification, and analysis of respirable dust data while providing for flexible export of data and linking with the USBM`s expert advisory system on dust control. An executable, IBM-compatible software was created and customized for use by the personmore » in charge of collecting, submitting, analyzing, and monitoring respirable dust compliance samples. Both descriptive statistics and multiple regression analysis were incorporated. The software allows ASCH files to be exported and directly links with DUSTPRO. After development and validation of the software, longwall compliance data from two different mines was analyzed to evaluate the value of the software. Data included variables on respirable dust concentration, tons produced, the existence of roof/floor rock (dummy variable), and the sampling cycle (dummy variables). Because of confidentiality, specific data will not be presented, only the equations and ANOVA tables. The final regression models explained 83.8% and 61.1% of the variation in the data for the two panels. Important correlations among variables within sampling cycles showed the value of using dummy variables for sampling cycles. The software proved flexible and fast for its intended use. The insights obtained from use improved the systematic monitoring of respirable dust compliance data, especially for pinpointing the most effective dust control methods during specific sampling cycles.« less
Ma, Jing; Horii, Yuichi; Cheng, Jinping; Wang, Wenhua; Wu, Qian; Ohura, Takeshi; Kannan, Kurunthachalam
2009-02-01
Chlorinated polycyclic aromatic hydrocarbons (CIPAHs) are a class of halogenated contaminants found in the urban atmosphere; they have toxic potential similar to that of dioxins. Information on the sources of CIPAHs is limited. In this study, concentrations of 20 CIPAHs and 16 parent PAHs were measured in electronic wastes, workshop-floor dust, vegetation, and surface soil collected from the vicinity of an electronic waste (e-waste) recycling facility and in surface soil from a chemical industrial complex (comprising a coke-oven plant, a coal-fired power plant, and a chlor-alkali plant), and agricultural areas in central and eastern China. High concentrations of SigmaCIPAHs were found in floor dust (mean, 103 ng/g dry wt), followed in order of decreasing concentration by leaves (87.5 ng/g drywt), electronic shredder waste (59.1 ng/g dry wt), and soil (26.8 ng/g dry wt) from an e-waste recycling facility in Taizhou. The mean concentration of SigmaCIPAHs in soil from the chemical industrial complex (88 ng/g dry wt) was approximately 3-fold higher than the concentration in soil from e-waste recycling facilities. The soils from e-waste sites and industrial areas contained mean concentrations of SigmaCIPAHs 2 to 3 orders of magnitude higher than the concentrations in agricultural soils (ND-0.76 ng/g), suggesting that e-waste recycling and chlorine-chemical industries are potential emission sources of CIPAHs. The profiles of CIPAHs in soil and dust were similar to a profile that has been reported previously for fly ash from municipal solid waste incinerators (6-CIBaP was the predominant compound), but the profiles in vegetation and electronic shredder waste were different from those found in fly ash. Concentrations of 16 parent PAHs were high (150-49,700 ng/g) in samples collected from the e-waste recycling facility. Significant correlation between SigmaCIPAH and SigmaPAH concentrations suggests that direct chlorination of parent PAHs is the major pathway of formation of CIPAHs during e-waste recycling operations. Dioxin-like toxic equivalency quotients (TEQs) for CIPAHs and PAHs in samples were calculated on the basis of relative potencies reported for CIPAHs and PAHs. The highest mean TEQ concentrations of CIPAHs (518 pg-TEQ/g) were found for workshop-floor dust, followed by leaves (361 pg-TEQ/g), electronic shredder waste (308 pg-TEQ/g), soil from the chemical industrial complex (146 pg-TEQ/g), and soil from the sites of the e-waste recycling facility (92.3 pg-TEQ/g). With one exception, the floor dust samples, the TEQ concentrations of CIPAHs found in multiple environmental matrices in this study were higher than the TEQ concentrations of PCDD/Fs in the same samples reported in our earlier study.
Kettleson, E; Kumar, S; Reponen, T; Vesper, S; Méheust, D; Grinshpun, S A; Adhikari, A
2013-10-01
Respiratory illnesses have been linked to children's exposures to water-damaged homes. Therefore, understanding the microbiome in water-damaged homes is critical to preventing these illnesses. Few studies have quantified bacterial contamination, especially specific species, in water-damaged homes. We collected air and dust samples in twenty-one low-mold homes and twenty-one high-mold homes. The concentrations of three bacteria/genera, Stenotrophomonas maltophilia, Streptomyces sp., and Mycobacterium sp., were measured in air and dust samples using quantitative PCR (QPCR). The concentrations of the bacteria measured in the air samples were not associated with any specific home characteristic based on multiple regression models. However, higher concentrations of S. maltophilia in the dust samples were associated with water damage, that is, with higher floor surface moisture and higher concentrations of moisture-related mold species. The concentrations of Streptomyces and Mycobacterium sp. had similar patterns and may be partially determined by human and animal occupants and outdoor sources of these bacteria. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Hallas, T E; Gislason, D; Björnsdottir, U S; Jörundsdottir, K B; Janson, C; Luczynska, C M; Gislason, T
2004-05-01
House dust mites are common sources of indoor allergens. In Reykjavik, Iceland, 9% of the young adult population had serum-specific IgE to Dermatophagoides pteronyssinus. Sensitization to mites is usually assumed to be due to exposure to house dust mites in the indoor environment. This investigation was carried out to measure the concentrations of house dust mite allergens and to investigate which species of mites were present in beds in Iceland. A total of 197 randomly selected adults were visited at home using the European Community Respiratory Health Survey (ECRHS) II Indoor protocol. Dust samples were collected from mattresses for measurement of house dust mite allergen concentrations and to estimate the number and type of house dust mites. Additional samples from mattresses and floors were collected from the homes of 10 patients with positive skin prick tests (SPT) to D. pteronyssinus. House dust mite allergen concentrations were measured using ELISA and examination of mite species was carried out using microscopy. Climatic parameters were assessed using psychrometer readings in the bedrooms and outdoors. We found two single mite specimens, both D. pteronyssinus, in two dust samples. Mite allergen analyses indicated that two other dust samples had Der f 1 results close to the cut-off of 0.1 microg/g of dust. No samples were positive for Der p 1. In an additional collection of dust from the homes of 10 SPT-positive patients no Dermatophagoides spp. were found. Reykjavik citizens are exposed to extremely low amounts of house dust mite allergens in their homes. Possible alternative sources for sensitization are discussed, such as bird nests, exposure from travelling abroad, or other mites or invertebrates that cross-react with house dust mite allergens. Our findings suggest that exposures other than to house dust mites indoors are possible sources of mite allergen exposure.
Kirychuk, Shelley P; Reynolds, Stephen J; Koehncke, Niels K; Lawson, Joshua; Willson, Philip; Senthilselvan, Ambikaipakan; Marciniuk, Darcy; Classen, Henry L; Crowe, Trever; Just, Natasha; Schneberger, David; Dosman, James A
2010-10-01
Individuals engaged in work in intensive animal houses experience some of the highest rates of occupationally related respiratory symptoms. Organic dust and in particular endotoxin has been most closely associated with respiratory symptoms and lung function changes in workers. It has previously been shown that for intensive poultry operations, type of poultry housing [cage-housed (CH) versus floor-housed (FH)] can influence the levels of environmental contaminants. The goal of the study was to determine the differences in endotoxin and dust levels at different size fractions between CH and FH poultry operations. Fifteen CH and 15 FH poultry operations were sampled for stationary measurements (area) of dust and associated endotoxin. Fractioned samples were collected utilizing Marple cascade impactors. Gravimetric and endotoxin analysis were conducted on each of the filters. When assessed by individual Marple stage, there was significantly greater airborne endotoxin concentration (endotoxin units per cubic meter) in the size fraction >9.8 μm for the FH operations whereas at the size fraction 1.6-3.5 μm, the CH operations had significantly greater airborne endotoxin concentration than the FH operations. Endotoxin concentration in the dust mass (endotoxin units per milligram) was significantly greater in the CH operations as compared to the FH operations for all size fractions >1.6 μm. As such, endotoxin in the respirable fraction accounted for 24% of the total endotoxin in the CH operations whereas it accounted for only 11% in the FH operations. There was significantly more dust in all size fractions in the FH operations as compared to the CH poultry operations. There is more endotoxin in the presence of significantly lower dust levels in the respirable particle size fractions in CH poultry operations as compared to the FH poultry operations. This difference in respirable endotoxin may be important in relation to the differential respiratory response experienced by CH and FH poultry operation workers.
Organophosphate flame retardants in the indoor air and dust in cars in Japan.
Tokumura, Masahiro; Hatayama, Rurika; Tatsu, Kouichi; Naito, Toshiyuki; Takeda, Tetsuya; Raknuzzaman, Mohammad; -Al-Mamun, Md Habibullah; Masunaga, Shigeki
2017-01-01
The concentrations of organophosphate flame retardants (OPFRs) in the indoor air and dust were measured in 25 unoccupied cars in Japan. In the indoor air of the cars, most OPFRs were neither detected nor found at a concentration lower than the method quantification limit. The highest concentration (1500 ng m -3 ) was obtained for tris(1-chloro-2-propyl) phosphate (TCIPP). By contrast, many OPFRs were detected in the dust samples collected from the interior of the cars. TCIPP and tris(2-ethylhexyl) phosphate (TEHP) were present at the highest concentrations at 390 μg g -1 (in dust from car seats) and 640 μg g -1 (in dust from car floor mats), respectively. The highest median concentrations (35 μg g -1 for car seats, 53 μg g -1 for car floor mats) were obtained for tris(2-butoxyethyl) phosphate (TBOEP). According to the results of our exposure assessment, the typical exposures to OPFRs via inhalation in car cabins ranged from 9.0×10 -4 to 7.8×10 -1 ng kg-bw -1 day -1 . The typical exposures to OPFRs via dust ingestion ranged from 9.2×10 -4 to 8.8×10 -1 ng kg-bw -1 day -1 . We compared these results with the ref-erence doses for OPFRs and found that, based on cur-rent information about the toxicities of OPFRs, exposure to OPFRs in car cabins via inhalation and dust ingestion is unlikely to have adverse human health effects.
Exposure assessment of heavy metals in an e-waste processing area in northern Vietnam.
Oguri, Tomoko; Suzuki, Go; Matsukami, Hidenori; Uchida, Natsuyo; Tue, Nguyen Minh; Tuyen, Le Huu; Viet, Pham Hung; Takahashi, Shin; Tanabe, Shinsuke; Takigami, Hidetaka
2018-04-15
In developing countries, inappropriate recycling of e-waste has resulted in the environmental release of toxicants, including heavy metals, that may have deleterious health effects. In this study, we estimated daily metal intakes in five households in a Vietnamese village located in an e-waste processing area and assessed the health risk posed by exposure to the metals. Garden soil, floor dust, 24-h duplicate diet, and ambient air samples were collected from five households in northern Vietnam in January 2014. All samples were acid-digested, and contents of Cd, Cu, Mn, Pb, Sb, and Zn were measured by using ICP mass spectrometry and ICP atomic emission spectroscopy. In addition, the soil, dust, and diet samples were subjected to an bioaccessibility extraction test to determine bioaccessible metal concentrations. Hazard quotients were estimated from bioaccessible metal concentrations, provisional tolerable weekly intakes, and reference doses. Garden soil and floor dust were estimated to be mainly contributors to daily Pb intake, as indicated by calculations using bioaccessible metal concentrations and the U.S. Environmental Protection Agency soil plus dust ingestion rate. Diet was suggested to contribute significantly to daily Cd, Cu, Mn, Sb, and Zn intake. Estimated metal exposures via inhalation were negligible, as indicated by calculations using International Atomic Energy Agency reference inhalation rates. The maximum hazard quotients were calculated as 0.2 (Cd), 0.09 (Cu), 0.3 (Mn), 0.6 (Pb), 0.2 (Sb), and 0.5 (Zn), on the basis of bioaccessible metal concentrations. The contributions of Cd, Cu, Mn, Sb, and Zn except Pb to potential noncancer risk for adult residents of the five households in the e-waste processing area may be low. Copyright © 2017 Elsevier B.V. All rights reserved.
Efficiency of wipe sampling on hard surfaces for pesticides and PCB residues in dust.
Cettier, Joane; Bayle, Marie-Laure; Béranger, Rémi; Billoir, Elise; Nuckols, John R; Combourieu, Bruno; Fervers, Béatrice
2015-02-01
Pesticides and polychlorinated biphenyls (PCBs) are commonly found in house dust and have been described as a valuable matrix to assess indoor pesticide and PCB contamination. The aim of this study was to assess the efficiency and precision of cellulose wipe for collecting 48 pesticides, eight PCBs, and one synergist at environmental concentrations. First, the efficiency and repeatability of wipe collection were determined for pesticide and PCB residues that were directly spiked onto three types of household floors (tile, laminate, and hardwood). Second, synthetic dust was used to assess the capacity of the wipe to collect dust. Third, we assessed the efficiency and repeatability of wipe collection of pesticides and PCB residues that was spiked onto synthetic dust and then applied to tile. In the first experiment, the overall collection efficiency was highest on tile (38%) and laminate (40%) compared to hardwood (34%), p<0.001. The second experiment confirmed that cellulose wipes can efficiently collect dust (82% collection efficiency). The third experiment showed that the overall collection efficiency was higher in the presence of dust (72% vs. 38% without dust, p<0.001). Furthermore, the mean repeatability also improved when compounds were spiked onto dust (<30% for the majority of compounds). To our knowledge, this is the first study to assess the efficiency of wipes as a sampling method using a large number of compounds at environmental concentrations and synthetic dust. Cellulose wipes appear to be efficient to sample the pesticides and PCBs that adsorb onto dust on smooth and hard surfaces. Copyright © 2014 Elsevier B.V. All rights reserved.
Dustborne and airborne gram-positive and gram-negative bacteria in high versus low ERMI homes
The study aimed at investigating Gram-positive and Gram-negative bacteria in moldy and non-moldy homes, as defined by the home's Environmental Relative Moldiness Index (ERMI) value. The ERMI values were determined from floor dust samples in 2010 and 2011 and homes were classified...
Endotoxins in indoor air and settled dust in primary schools in a subtropical climate.
Salonen, Heidi; Duchaine, Caroline; Létourneau, Valérie; Mazaheri, Mandana; Clifford, Sam; Morawska, Lidia
2013-09-03
Endotoxins can significantly affect the air quality in school environments. However, there is currently no reliable method for the measurement of endotoxins, and there is a lack of reference values for endotoxin concentrations to aid in the interpretation of measurement results in school settings. We benchmarked the "baseline" range of endotoxin concentration in indoor air, together with endotoxin load in floor dust, and evaluated the correlation between endotoxin levels in indoor air and settled dust, as well as the effects of temperature and humidity on these levels in subtropical school settings. Bayesian hierarchical modeling indicated that the concentration in indoor air and the load in floor dust were generally (<95th percentile) <13 EU/m(3) and <24,570 EU/m(2), respectively. Exceeding these levels would indicate abnormal sources of endotoxins in the school environment and the need for further investigation. Metaregression indicated no relationship between endotoxin concentration and load, which points to the necessity for measuring endotoxin levels in both the air and settled dust. Temperature increases were associated with lower concentrations in indoor air and higher loads in floor dust. Higher levels of humidity may be associated with lower airborne endotoxin concentrations.
Transport of lawn-applied 2,4-D into 13 actual homes was measured following both homeowner and commercial application of this herbicide to residential lawns. Collection of floor dust in five rooms of each house, corresponding to an entryway, living room, dining room, kitchen, a...
Molds and mycotoxins in indoor environments--a survey in water-damaged buildings.
Bloom, Erica; Nyman, Eva; Must, Aime; Pehrson, Christina; Larsson, Lennart
2009-11-01
Mycotoxins are toxic, secondary metabolites frequently produced by molds in water-damaged indoor environments. We studied the prevalence of selected, potent mycotoxins and levels of fungal biomass in samples collected from water-damaged indoor environments in Sweden during a 1-year period. One hundred samples of building materials, 18 samples of settled dust, and 37 samples of cultured dust were analyzed for: (a) mycoflora by microscopy and culture; (b) fungal chemical marker ergosterol and hydrolysis products of macrocyclic trichothecenes and trichodermin (verrucarol and trichodermol) by gas chromatography-tandem mass spectrometry; and (c) sterigmatocystin, gliotoxin, aflatoxin B(1), and satratoxin G and H by high performance liquid chromatography-tandem mass spectrometry. Sixty-six percent of the analyzed building materials samples, 11% of the settled dust samples, and 51% of the cultured dust samples were positive for at least one of the studied mycotoxins. In addition, except in the case of gliotoxin, mycotoxin-positive building material samples contained 2-6 times more ergosterol than mycotoxin-negative samples. We show that (a) molds growing on a range of different materials indoors in water-damaged buildings generally produce mycotoxins, and (b) mycotoxin-containing particles in mold-contaminated environments may settle on surfaces above floor level. The mass spectrometry methods used in this study are valuable tools in further research to survey mycotoxin exposure and investigate potential links with health effects.
Radioactive Iron Rain: Transporting 60Fe in Supernova Dust to the Ocean Floor
NASA Astrophysics Data System (ADS)
Fry, Brian J.; Fields, Brian D.; Ellis, John R.
2016-08-01
Several searches have found evidence of {}60{{Fe}} deposition, presumably from a near-Earth supernova (SN), with concentrations that vary in different locations on Earth. This paper examines various influences on the path of interstellar dust carrying {}60{{Fe}} from an SN through the heliosphere, with the aim of estimating the final global distribution on the ocean floor. We study the influences of magnetic fields, angle of arrival, wind, and ocean cycling of SN material on the concentrations at different locations. We find that the passage of SN material through the mesosphere/lower thermosphere has the greatest influence on the final global distribution, with ocean cycling causing lesser alteration as the SN material sinks to the ocean floor. SN distance estimates in previous works that assumed a uniform distribution are a good approximation. Including the effects on surface distributions, we estimate a distance of {46}-6+10 pc for an 8{--}10 {M}⊙ SN progenitor. This is consistent with an SN occurring within the Tuc-Hor stellar group ˜2.8 Myr ago, with SN material arriving on Earth ˜2.2 Myr ago. We note that the SN dust retains directional information to within 1◦ through its arrival in the inner solar system, so that SN debris deposition on inert bodies such as the Moon will be anisotropic, and thus could in principle be used to infer directional information. In particular, we predict that existing lunar samples should show measurable {}60{{Fe}} differences.
Organophosphorus flame retardants and plasticizers in air from various indoor environments.
Marklund, Anneli; Andersson, Barbro; Haglund, Peter
2005-08-01
Eleven organophosphorus compounds (OPs) that are used as plasticizers and flame retardants were analysed in duplicate samples of indoor air from 17 domestic and occupational environments. Solid-phase extraction (SPE) columns were used as adsorbents and analysis was performed using GC with a nitrogen phosphorus selective detector. The total amounts of OPs in the air samples ranged between 36 and 950 ng m(-3); tris(chloropropyl) phosphate (TCPP) and tris(2-chloroethyl) phosphate (TCEP) being the most abundant (0.4 to 730 ng m(-3)), followed by tributyl phosphate (0.5-120 ng m(-3)). Public buildings tended to have about 3-4 times higher levels of OPs than domestic buildings. The relative amounts of individual OPs varied between the sites and generally reflected the building materials, furniture and consumer products used in the sampled environments. Potential sources of these compounds include, inter alia, acoustic ceilings, upholstered furniture, wall coverings, floor polish and polyvinylchloride floor coverings. A correlation was observed between the TCEP concentrations in the air in the sampled environments and previously reported concentrations in dust, but no such correlation was seen for the heavier and less volatile tris(2-butoxyethyl) phosphate (TBEP). Based on estimated amounts of indoor air inhaled and dust ingested, adults and children in the sampled environments would be exposed to up to 5.8 microg kg(-1) day(-1) and 57 microg kg(-1) day(-1) total OPs, respectively.
Household characteristics and allergen and endotoxin levels in Aleppo, Syrian Arab Republic.
Al Ali, W; Custovic, A; Simpson, A; Khoury, A; Woodcock, A
2010-07-01
Few data are available from Eastern Mediterranean countries about levels of domestic allergens and endotoxins. Dust samples were collected from mattresses and floors of 457 homes in the Syrian city of Aleppo and analysed for antigens and endotoxins. The most important predictors for detectable levels of house-dust mite allergen Der p 1 were Arabic-style houses (OR 3.21) and newer houses (OR 1.56). In homes without cats, rubber mattresses were associated with detectable cat allergen Fel d 1 in mattress dust (OR 1.6). Cockroach allergen Bla g 2 was significantly more likely to be detected in houses over 20 years old than newer houses. Endotoxin levels were significantly higher in wool/cotton mattresses and older houses.
Assessment of Child Lead Exposure in a Philadelphia Community, 2014.
Dignam, Timothy; Pomales, Ana; Werner, Lora; Newbern, E Claire; Hodge, James; Nielsen, Jay; Grober, Aaron; Scruton, Karen; Young, Rand; Kelly, Jack; Brown, Mary Jean
2018-01-10
Several urban neighborhoods in Philadelphia, Pennsylvania, have a history of soil, household lead paint, and potential lead-emitting industry contamination. To (1) describe blood lead levels (BLLs) in target neighborhoods, (2) identify risk factors and sources of lead exposure, (3) describe household environmental lead levels, and (4) compare results with existing data. A simple, random, cross-sectional sampling strategy was used to enroll children 8 years or younger living in selected Philadelphia neighborhoods with a history of lead-emitting industry during July 2014. Geometric mean of child BLLs and prevalence of BLLs of 5 μg/dL or more were calculated. Linear and logistic regression analyses were used to ascertain risk factors for elevated BLLs. Among 104 children tested for blood lead, 13 (12.4%; 95% confidence interval [CI], 7.5-20.2) had BLLs of 5 μg/dL or more. The geometric mean BLL was 2.0 μg/dL (95% CI, 1.7-2.3 μg/dL). Higher geometric mean BLLs were significantly associated with front door entryway dust lead content, residence built prior to 1900, and a child currently or ever receiving Medicaid. Seventy-one percent of households exceeded the screening level for soil, 25% had an elevated front door floor dust lead level, 28% had an elevated child play area floor dust lead level, and 14% had an elevated interior window dust lead level. Children in households with 2 to 3 elevated environmental lead samples were more likely to have BLLs of 5 μg/dL or more. A spatial relationship between household proximity to historic lead-emitting facilities and child BLL was not identified. Entryway floor dust lead levels were strongly associated with blood lead levels in participants. Results underscore the importance to make housing lead safe by addressing all lead hazards in and around the home. Reduction of child lead exposure is crucial, and continued blood lead surveillance, testing, and inspection of homes of children with BLLs of 5 μg/dL or more to identify and control lead sources are recommended. Pediatric health care providers can be especially vigilant screening Medicaid-eligible/enrolled children and children living in very old housing.
Removal of lead contaminated dusts from hard surfaces.
Lewis, Roger D; Condoor, Sridhar; Batek, Joe; Ong, Kee Hean; Backer, Denis; Sterling, David; Siria, Jeff; Chen, John J; Ashley, Peter
2006-01-15
Government guidelines have widely recommended trisodium phosphate (TSP) or "lead-specific" cleaning detergents for removal of lead-contaminated dust (LCD) from hard surfaces, such as floors and window areas. The purpose of this study was to determine if low-phosphate, non-lead-specific cleaners could be used to efficiently remove LCD from 3 types of surfaces (vinyl flooring, wood, and wallpaper). Laboratory methods were developed and validated for simulating the doping, embedding, and sponge cleaning of the 3 surface types with 4 categories of cleaners: lead-specific detergents, nonionic cleaners, anionic cleaners, and trisodium phosphate (TSP). Vinyl flooring and wood were worn using artificial means. Materials were ashed, followed by ultrasound extraction, and anodic stripping voltammetry (ASV). One-way analysis of variance approach was used to evaluate the surface and detergent effects. Surface type was found to be a significant factor in removal of lead (p < 0.001). Vinyl flooring cleaned better than wallpaper by over 14% and wood cleaned better than wallpaper by 13%. There was no difference between the cleaning action of vinyl flooring and wood. No evidence was found to support the use of TSP or lead-specific detergents over all-purpose cleaning detergents for removal of lead-contaminated dusts. No-phosphate, non-lead-specific detergents are effective in sponge cleaning of lead-contaminated hard surfaces and childhood lead prevention programs should consider recommending all-purpose household detergents for removal of lead-contaminated dust after appropriate vacuuming.
Report of sampling and analysis results, Addison Army housing units, Addison, Illinois. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1990-09-01
The objectives of this sampling and analysis effort include further characterization of environmental contamination identified in an enhanced preliminary assessment carried out in 1989. The specific activities performed at this site were identification, evaluation of the condition, and collection of samples from specific suspected asbestos-containing materials, including floor tiles, pipe run and pipe fitting insulation, dust in the ductwork, and exterior siding, where present. These evaluation were necessary to clarify potential environmental issues identified in the earlier report, prior to the sale or realignment of the property.
Associations between PBDEs in Office Air, Dust, and Surface Wipes
Watkins, Deborah J.; McClean, Michael D.; Fraser, Alicia J.; Weinberg, Janice; Stapleton, Heather M.; Webster, Thomas F.
2013-01-01
Increased use of flame-retardants in office furniture may increase exposure to PBDEs in the office environment. However, partitioning of PBDEs within the office environment is not well understood. Our objectives were to examine relationships between concurrent measures of PBDEs in office air, floor dust, and surface wipes. We collected air, dust, and surface wipe samples from 31 offices in Boston, MA. Correlation and linear regression were used to evaluate associations between variables. Geometric mean (GM) concentrations of individual BDE congeners in air and congener specific octanol-air partition coefficients (Koa) were used to predict GM concentrations in dust and surface wipes and compared to the measured concentrations. GM concentrations of PentaBDEs in office air, dust, and surface wipes were 472 pg/m3, 2411 ng/g, and 77 pg/cm2, respectively. BDE209 was detected in 100% of dust samples (GM=4202 ng/g), 93% of surface wipes (GM=125 pg/cm2), and 39% of air samples. PentaBDEs in dust and air were moderately correlated with each other (r=0.60, p=0.0003), as well as with PentaBDEs in surface wipes (r=0.51, p=0.003 for both dust and air). BDE209 in dust was correlated with BDE209 in surface wipes (r=0.69, p=0.007). Building (three categories) and PentaBDEs in dust were independent predictors of PentaBDEs in both air and surface wipes, together explaining 50% (p=0.0009) and 48% (p=0.001) of the variation respectively. Predicted and measured concentrations of individual BDE congeners were highly correlated in dust (r=0.98, p<0.0001) and surface wipes (r=0.94, p=002). BDE209 provided an interesting test of this equilibrium partitioning model as it is a low volatility compound. Associations between PentaBDEs in multiple sampling media suggest that collecting dust or surface wipes may be a convenient method of characterizing exposure in the indoor environment. The volatility of individual congeners, as well as physical characteristics of the indoor environment, influence relationships between PBDEs in air, dust, and surface wipes. PMID:23797055
Genesis: Removing Contamination from Sample Collectors
NASA Technical Reports Server (NTRS)
Lauer, H. V.; McNamara, K. M.; Westphal, Andrew; Butterworth, A. L.; Burnett, D. S.; Jurewicz, A.; Woolum, D.; Allton, J. H.
2005-01-01
The Genesis mission returned to Earth on September 8, 2004, experiencing a non-nominal reentry. The parachutes which were supposed to slow and stabilize the capsule throughout the return failed to deploy, causing the capsule to impact the desert floor at a speed of nearly 200 MPH. Both the science canister and the major components of the SRC were returned before nightfall on September 8 to the prestaged cleanroom at UTTR , avoiding prolonged exposure or pending weather changes which might further contaminate the samples. The majority of the contaminants introduced as a result of the anomalous landing were in the form of particulates, including UTTR dust and soil, carbon-carbon heat shield material, and shattered collector dust (primarily silicon and germanium). Additional information is included in the original extended abstract.
30 CFR 75.403 - Maintenance of incombustible content of rock dust.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Maintenance of incombustible content of rock... Materials and Rock Dusting § 75.403 Maintenance of incombustible content of rock dust. [Statutory Provision] Where rock dust is required to be applied, it shall be distributed upon the top, floor, and sides of all...
Clausen, Per Axel; Hansen, Vivi; Gunnarsen, Lars; Afshari, Alireza; Wolkoff, Peder
2004-05-01
The emission of di-2-ethylhexyl phthalate (DEHP) from a PVC flooring was studied for up to 472 days in both the FLEC (Field and Laboratory Emission Cell) and the CLIMPAQ (Chamberfor Laboratory Investigations of Materials, Pollution, and Air Quality). The loading of the CLIMPAQs was varied but was constant in the FLECs. The sorption properties of FLEC and CLIMPAQ were investigated using different methods. In addition, the uptake of DEHP by office floor dust on the PVC flooring was studied in CLIMPAQ experiments. The concentration versus time curves in both FLECs and CLIMPAQs increased slowly over about 150 days and reached a quasi-static equilibrium at 1 microg m(-3). The main conclusions were that (i) the emission rate of DEHP was limited by gas-phase mass transport and (ii) the dust layer increased the emission rate by increasing the external concentration gradient above the surface of the PVC. These conclusions were based on the facts that the specific emission rate was inversely proportional to the loading and that the dust had sorbed about four times as much DEHP over a 68-day period as emitted in the gas-phase experiments. About one-half of the emitted DEHP was deposited on the internal surfaces of both the FLEC and the CLIMPAQ.
Johnston, J D; Kruman, B A; Nelson, M C; Merrill, R M; Graul, R J; Hoybjerg, T G; Tuttle, S C; Myers, S J; Cook, R B; Weber, K S
2017-09-01
Residential endotoxin exposure is associated with protective and pathogenic health outcomes. Evaporative coolers, an energy-efficient type of air conditioner used in dry climates, are a potential source of indoor endotoxins; however, this association is largely unstudied. We collected settled dust biannually from four locations in homes with evaporative coolers (n=18) and central air conditioners (n=22) in Utah County, Utah (USA), during winter (Jan-Apr) and summer (Aug-Sept), 2014. Dust samples (n=281) were analyzed by the Limulus amebocyte lysate test. Housing factors were measured by survey, and indoor temperature and relative humidity measures were collected during both seasons. Endotoxin concentrations (EU/mg) were significantly higher in homes with evaporative coolers from mattress and bedroom floor samples during both seasons. Endotoxin surface loads (EU/m 2 ) were significantly higher in homes with evaporative coolers from mattress and bedroom floor samples during both seasons and in upholstered furniture during winter. For the nine significant season-by-location comparisons, EU/mg and EU/m 2 were approximately three to six times greater in homes using evaporative coolers. A plausible explanation for these findings is that evaporative coolers serve as a reservoir and distribution system for Gram-negative bacteria or their cell wall components in homes. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Silicon Carbide Found in K/T Boundary Layer: Implication for Asteroid Collision with Planet Earth
NASA Astrophysics Data System (ADS)
Leung, I. S.; Tsao, C.
2016-12-01
An event at the end of the Cretaceous Period 65.5 m.y. ago produced an impact structure 300 km in diameter designated the Chicxulub Crater, located partly on the Yucatan Peninsula and the Caribbian Sea floor. Mass extinction following that event killed 75% of Earth's living species, including dinosaurs. To this date, the killer space object has not been identified, but it was frequently conjectured to be a comet or an asteroid. The goal of our study was to search for evidence which might implicate the culprit. The Chicxulub impact caused extensive wildfires producing Ir-rich dust fallouts in worldwide localities, among which the least contaminated by land-derived sediments may be situated on deep ocean floors. Our study is based on a sample of pelagic clay from the giant piston core LL44-GPC3 taken from the Pacific Plate, north of the Hawaiian Islands (Woods Hole Oceanographic Institution). The 1-cm thick Ir-rich layer was located at a downcore depth of 1055-1056 cm below sea floor. From a 5 cubic cm sample provided by Jim Broda, we found 29 impact glass spherules and 4 silicon carbide (SiC) crystals. SiC has been reported in carbonaceous meteorites. Our findings of SiC in the K/T boundary layer seem to implicate that an asteroid having composition akin to that of carbonaceous chondrites might have been the killer projectile during the Chicxulub event. However, impact by a comet cannot be ruled out, since the mineralogy of cometary dust is as yet unknown.
Prevention of Salmonella cross-contamination in an oilmeal manufacturing plant.
Morita, T; Kitazawa, H; Iida, T; Kamata, S
2006-08-01
The mechanisms of Salmonella contamination in an oilmeal plant were investigated and the basic data were collected in order to achieve control of Salmonella in oilmeal. Salmonella was detected in all contamination vectors and environmental factors investigated, namely: operators, processing floor, dust in the air and rodents. In particular, high concentrations of Salmonella were detected on the processing floor of the manufacturing area, which has high oil content. Steam was the most effective disinfection method used for the processing floor, as the effects of heat sterilization and disinfection may work in tandem. In addition, restricting the movement of operators of the production chain remarkably reduced Salmonella contamination, even in areas of otherwise high contamination. Within the oilmeal plant, high Salmonella contamination rates for the processing floor represent the greatest risk of contamination of oilmeal via operators, dust in the air and rodents. Therefore, control of the processing floor is the most important means for reducing the oilmeal contamination rate. Specific Salmonella control methods for oilmeal plants have been established.
Materials characterization of dusts generated by the collapse of the World Trade Center
Meeker, Gregory P.; Sutley, Stephen J.; Brownfield, Isabelle; Lowers, Heather; Bern, Amy M.; Swayze, Gregg A.; Hoefen, Todd M.; Plumlee, Geoffrey S.; Clark, Roger N.; Gent, Carol A.
2009-01-01
The major inorganic components of the dusts generated from the collapse of the World Trade Center buildings on September 11, 2001 were concrete materials, gypsum, and man-made vitreous fibers. These components were likely derived from lightweight Portland cement concrete floors, gypsum wallboard, and spray-on fireproofing and ceiling tiles, respectively. All of the 36 samples collected by the USGS team had these materials as the three major inorganic components of the dust. Components found at minor and trace levels include chrysotile asbestos, lead, crystalline silica, and particles of iron and zinc oxides. Other heavy metals, such as lead, bismuth, copper, molybdenum, chromium, and nickel, were present at much lower levels occurring in a variety of chemical forms. Several of these materials have health implications based on their chemical composition, morphology, and bioaccessibility.
Fungal and bacterial growth in floor dust at elevated relative humidity levels.
Dannemiller, K C; Weschler, C J; Peccia, J
2017-03-01
Under sustained, elevated building moisture conditions, bacterial and fungal growth occurs. The goal of this study was to characterize microbial growth in floor dust at variable equilibrium relative humidity (ERH) levels. Floor dust from one home was embedded in coupons cut from a worn medium-pile nylon carpet and incubated at 50%, 80%, 85%, 90%, 95%, and 100% ERH levels. Quantitative PCR and DNA sequencing of ribosomal DNA for bacteria and fungi were used to quantify growth and community shifts. Over a 1-wk period, fungal growth occurred above 80% ERH. Growth rates at 85% and 100% ERH were 1.1 × 10 4 and 1.5 × 10 5 spore equivalents d -1 mg dust -1 , respectively. Bacterial growth occurred only at 100% ERH after 1 wk (9.0 × 10 4 genomes d -1 mg dust -1 ). Growth resulted in significant changes in fungal (P<.00001) and bacterial community structure (P<.00001) at varying ERH levels. Comparisons between fungal taxa incubated at different ERH levels revealed more than 100 fungal and bacterial species that were attributable to elevated ERH. Resuspension modeling indicated that more than 50% of airborne microbes could originate from the resuspension of fungi grown at ERH levels of 85% and above. © 2016 The Authors. Indoor Air published by John Wiley & Sons Ltd.
Wang, Wenzheng; Wang, Yanming; Shi, Guoqing
2015-12-10
Comprehensive experimental research on the fundamental optical properties of dust pollution in a coal mine is presented. Rock dust generated in a tunneling roadway was sampled and the spectral complex refractive index within an infrared range of 2.5-25 μm was obtained by Fourier transform infrared spectroscopy measurement and Kramers-Kronig relation. Experimental results were validated to be consistent with equivalent optical constants simulated by effective medium theory based on component analysis of x-ray fluorescence, which illustrates that the top three mineral components are SiO2 (62.06%), Al2O3 (21.26%), and Fe2O3 (4.27%). The complex refractive index and the spatial distribution tested by a filter dust and particle size analyzer were involved in the simulation of extinction properties of rock dust along the tunneling roadway solved by the discrete ordinates method and Mie scattering model. The compared results illustrate that transmission is obviously enhanced with the increase of height from the floor but weakened with increasing horizontal distance from the air duct.
Dust-bathing behavior of laying hens in enriched colony housing systems and an aviary system
Louton, H.; Bergmann, S.; Reese, S.; Erhard, M. H.; Rauch, E.
2016-01-01
The dust-bathing behavior of Lohmann Selected Leghorn hens was compared in 4 enriched colony housing systems and in an aviary system. The enriched colony housing systems differed especially in the alignment and division of the functional areas dust bath, nest, and perches. Forty-eight-hour video recordings were performed at 3 time-points during the laying period, and focal animal sampling and behavior sampling methods were used to analyze the dust-bathing behavior. Focal animal data included the relative fractions of dust-bathing hens overall, of hens bathing in the dust-bath area, and of those bathing on the wire floor throughout the day. Behavior data included the number of dust-bathing bouts within a predefined time range, the duration of 1 bout, the number of and reasons for interruptions, and the number of and reasons for the termination of dust-bathing bouts. Results showed that the average duration of dust bathing varied between the 4 enriched colony housing systems compared with the aviary system. The duration of dust-bathing bouts was shorter than reported under natural conditions. A positive correlation between dust-bathing activity and size of the dust-bath area was observed. Frequently, dust baths were interrupted and terminated by disturbing influences such as pecking by other hens. This was especially observed in the enriched colony housing systems. In none of the observed systems, neither in the enriched colony housing nor in the aviary system, were all of the observed dust baths terminated “normally.” Dust bathing behavior on the wire mesh rather than in the provided dust-bath area generally was observed at different frequencies in all enriched colony housing systems during all observation periods, but never in the aviary system. The size and design of the dust-bath area influenced the prevalence of dust-bathing behavior in that small and subdivided dust-bath areas reduced the number of dust-bathing bouts but increased the incidence of sham dust bathing on the wire mesh. PMID:27044875
Rare earth elements and select actinoids in the Canadian House Dust Study.
Rasmussen, P E; Levesque, C; Chénier, M; Gardner, H D
2017-09-01
Nationally representative baseline data are presented for rare earth elements (REE), thorium (Th) and uranium (U) in house dust sampled from 1025 urban homes, in units of concentrations (μg g -1 ), loadings (μg m -2 ), and loading rates (ng m -2 d -1 ). Spearman rank correlations indicate that, in addition to outdoor sources, consumer products and building materials can influence indoor dust concentrations of REE, Th, and U. Correlations (P<.01) with numbers of occupants, dogs, and cats suggest soil track-in. Correlations (P<.01) with hardwood floors suggest release of REE additives used in pigments and coatings during daily wear and tear. Concentrations of light REE are elevated in smokers' homes compared to non-smokers' homes (P<.001), suggesting that a key source is "mischmetal," the REE alloy used in cigarette-lighter flints. Indoor sources include geological impurities in raw materials used in consumer products, such as U and Th impurities in bentonite clay used in cat litter, and REE impurities in phosphates used for a variety of applications including dog food and building materials. Median gastric bioaccessibility (pH 1.5) of most REE in dust ranges from about 20% to 29%. Household vacuum samples correlate with fresh dust samples from the same homes (P<.001 for all investigated elements). © 2017 Her Majesty the Queen in Right of Canada Indoor Air © 2017 John Wiley & Sons Ltd.
No Concentration Decrease of House Dust Mite Allergens With Rising Altitude in Alpine Regions
Grafetstätter, Carina; Prossegger, Johanna; Braunschmid, Herbert; Sanovic, Renata; Hahne, Penelope; Pichler, Christina; Thalhamer, Josef
2016-01-01
Purpose Several studies over the past 4 decades have indicated a significant reduction in house dust mite (HDM) and HDM allergen concentration in areas higher than 1,500 m above sea level. These have served as basis of allergen avoidance therapies for HDM allergy and asthma. However, modern construction techniques used in the insulation, heating, and glazing of buildings as well as global warming have changed the environmental parameters for HDM living conditions. The present study revisits the paradigm of decreasing HDM allergen concentrations with increasing altitude in the alpine region of Germany and Austria. Methods A total of 122 dust samples from different abodes (hotels, privates and mountain huts) at different altitudes (400-2,600 m) were taken, and concentrations of HDM allergens were analyzed. Humidity and temperature conditions, and numerous indoor environmental parameters such as fine dust, type of flooring, age of building, and frequency of cleaning were determined. Results HDM allergen concentrations did not significantly change with increasing altitude or relative humidity. At the level of indoor parameters, correlations could be found for different flooring types and the concentration of HDM allergens. Conclusions In contrast to the widespread view of the relationship between altitude and HDM allergen concentrations, clinically relevant concentrations of HDM allergens could be detected in high-lying alpine regions in Austria and Germany. These results indicate that improvement in conditions of asthmatic patients sensitized against HDMs during a stay at high altitude can no longer be ascribed to decreased levels of HDM allergens, instead, other mechanisms may trigger the beneficial effect. PMID:27126724
No Concentration Decrease of House Dust Mite Allergens With Rising Altitude in Alpine Regions.
Grafetstätter, Carina; Prossegger, Johanna; Braunschmid, Herbert; Sanovic, Renata; Hahne, Penelope; Pichler, Christina; Thalhamer, Josef; Hartl, Arnulf
2016-07-01
Several studies over the past 4 decades have indicated a significant reduction in house dust mite (HDM) and HDM allergen concentration in areas higher than 1,500 m above sea level. These have served as basis of allergen avoidance therapies for HDM allergy and asthma. However, modern construction techniques used in the insulation, heating, and glazing of buildings as well as global warming have changed the environmental parameters for HDM living conditions. The present study revisits the paradigm of decreasing HDM allergen concentrations with increasing altitude in the alpine region of Germany and Austria. A total of 122 dust samples from different abodes (hotels, privates and mountain huts) at different altitudes (400-2,600 m) were taken, and concentrations of HDM allergens were analyzed. Humidity and temperature conditions, and numerous indoor environmental parameters such as fine dust, type of flooring, age of building, and frequency of cleaning were determined. HDM allergen concentrations did not significantly change with increasing altitude or relative humidity. At the level of indoor parameters, correlations could be found for different flooring types and the concentration of HDM allergens. In contrast to the widespread view of the relationship between altitude and HDM allergen concentrations, clinically relevant concentrations of HDM allergens could be detected in high-lying alpine regions in Austria and Germany. These results indicate that improvement in conditions of asthmatic patients sensitized against HDMs during a stay at high altitude can no longer be ascribed to decreased levels of HDM allergens, instead, other mechanisms may trigger the beneficial effect.
3. SIXTH FLOOR VIEW TO WEST, WITH FACE POWDER MAKING ...
3. SIXTH FLOOR VIEW TO WEST, WITH FACE POWDER MAKING UNIT: CHARGE HOPPER (CENTER FOREGROUND), PERFUME MIXER (LEFT), AND DUST COLLECTOR (REAR CENTER) - Colgate & Company Jersey City Plant, G Block, 81-95 Greene Street, Jersey City, Hudson County, NJ
A first generation dynamic ingress, redistribution and transport model of soil track-in: DIRT.
Johnson, D L
2008-12-01
This work introduces a spatially resolved quantitative model, based on conservation of mass and first order transfer kinetics, for following the transport and redistribution of outdoor soil to, and within, the indoor environment by track-in on footwear. Implementations of the DIRT model examined the influence of room size, rug area and location, shoe size, and mass transfer coefficients for smooth and carpeted floor surfaces using the ratio of mass loading on carpeted to smooth floor surfaces as a performance metric. Results showed that in the limit for large numbers of random steps the dual aspects of deposition to and track-off from the carpets govern this ratio. Using recently obtained experimental measurements, historic transport and distribution parameters, cleaning efficiencies for the different floor surfaces, and indoor dust deposition rates to provide model boundary conditions, DIRT predicts realistic floor surface loadings. The spatio-temporal variability in model predictions agrees with field observations and suggests that floor surface dust loadings are constantly in flux; steady state distributions are hardly, if ever, achieved.
Vredegoor, Doris W; Willemse, Ton; Chapman, Martin D; Heederik, Dick J J; Krop, Esmeralda J M
2012-10-01
Certain dog breeds are described and marketed as being "hypoallergenic" on the basis of anecdotal reports that these dogs are better tolerated by patients allergic to dogs. These observations were investigated by comparing Can f 1 (major dog [Canis familiaris] allergen) levels in hair and coat samples and in the home environment of various hypoallergenic (Labradoodle, Poodle, Spanish Waterdog, and Airedale terrier) and non-hypoallergenic dogs (Labrador retriever and a control group). Hair and coat samples were obtained from dogs, and settled floor and airborne dust samples were taken from the dogs' homes. Can f 1 concentrations were measured by using ELISA, and results were analyzed by using multiple linear regression analyses. Significantly higher Can f 1 concentrations were found in hair and coat samples of hypoallergenic dogs (n = 196, geometric mean [GM], 2.26 μg/g, geometric standard deviation [GSD], 0.73, and GM, 27.04 μg/g, GSD, 0.57, respectively) than of non-hypoallergenic dogs (n = 160, GM, 0.77 μg/g, GSD, 0.71, and GM, 12.98 μg/g, GSD, 0.76, respectively). Differences between breeds were small, relative to the variability within a breed. Can f 1 levels in settled floor dust samples were lower for Labradoodles, but no differences were found between the other groups. No differences in airborne levels were found between breeds. So-called hypoallergenic dogs had higher Can f 1 levels in hair and coat samples than did control breeds. These differences did not lead to higher levels of environmental exposure to dog allergens. There is no evidence for the classification of certain dog breeds as being "hypoallergenic." Copyright © 2012 American Academy of Allergy, Asthma & Immunology. Published by Mosby, Inc. All rights reserved.
House dust mites, our intimate associates.
Nadchatram, M
2005-06-01
House dust mites have lived in human contact from time immemorial. Human dander or dead skin constitutes the major organic component of the house dust ecosystem. Because the mites feed on dander, dust mites and human association will continue to co-exist as part of our environment. Efficient house-keeping practice is the best form of control to reduce infestation. However, special precautions are important when individuals are susceptible or sensitive to dust mites. House dust mites are responsible for causing asthma, rhinitis and contact dermatitis. The respiratory allergies are caused by the inhalation of dead or live mites, their faecal matter or other byproducts. Immune factors are of paramount importance in the development of dust related or mite induced respiratory diseases. House dust mites were found in some 1,000 samples of dust taken from approximately 330 dwellings in Peninsular Malaysia and Singapore. Mattresses, carpets, corners of a bedroom, and floor beneath the bed are favourable dust mite habitats. The incriminating species based on studies here and elsewhere, as well as many other species of dust mites of unknown etiological importance are widely distributed in Malaysian homes. Density of dust mites in Malaysia and Singapore is greater than in temperate countries. Prevention and control measures with reference to subjects sensitive to dust mite allergies, including chemical control described in studies conducted in Europe and America are discussed. However, a cost free and most practical way to remove mites, their faecal matter and other products is to resort to sunning the bedding and carpets to kill the living mites, and then beaten and brushed to remove the dust and other components.
Shahan, M R; Seaman, C E; Beck, T W; Colinet, J F; Mischler, S E
2017-09-01
Float coal dust is produced by various mining methods, carried by ventilating air and deposited on the floor, roof and ribs of mine airways. If deposited, float dust is re-entrained during a methane explosion. Without sufficient inert rock dust quantities, this float coal dust can propagate an explosion throughout mining entries. Consequently, controlling float coal dust is of critical interest to mining operations. Rock dusting, which is the adding of inert material to airway surfaces, is the main control technique currently used by the coal mining industry to reduce the float coal dust explosion hazard. To assist the industry in reducing this hazard, the Pittsburgh Mining Research Division of the U.S. National Institute for Occupational Safety and Health initiated a project to investigate methods and technologies to reduce float coal dust in underground coal mines through prevention, capture and suppression prior to deposition. Field characterization studies were performed to determine quantitatively the sources, types and amounts of dust produced during various coal mining processes. The operations chosen for study were a continuous miner section, a longwall section and a coal-handling facility. For each of these operations, the primary dust sources were confirmed to be the continuous mining machine, longwall shearer and conveyor belt transfer points, respectively. Respirable and total airborne float dust samples were collected and analyzed for each operation, and the ratio of total airborne float coal dust to respirable dust was calculated. During the continuous mining process, the ratio of total airborne float coal dust to respirable dust ranged from 10.3 to 13.8. The ratios measured on the longwall face were between 18.5 and 21.5. The total airborne float coal dust to respirable dust ratio observed during belt transport ranged between 7.5 and 21.8.
Enhanced Saharan dust input to the Levant during Heinrich stadials
NASA Astrophysics Data System (ADS)
Torfstein, Adi; Goldstein, Steven L.; Stein, Mordechai
2018-04-01
The history of dust transport to the Levant during the last glacial period is reconstructed using the isotope ratios of Pb, Sr, Nd, and Hf in sediments of Lake Lisan, the last glacial Dead Sea. Exposed marginal sections of the Lisan Formation were sampled near Masada, the Perazim Valley and from a core drilled at the deep floor of the modern lake. Bulk samples and size fractions display unique isotopic fingerprints: the finest detritus fraction (<5 μm) displays higher 87Sr/86Sr and lower εNd values (0.710-0.713 and -7.0 to -9.8, respectively) relative to the coarser fractions (5-20 μm and <20 μm; 0.708-0.710 and -3.4 to -8.3) and the bulk detritus samples (0.709-0.711 and -6 to -7.5). Similarly, the 206Pb/204Pb, 207Pb/204Pb and 208Pb/204Pb ratios (18.26-19.02, 15.634-15.68, and 38.25-38.82, respectively) are systematically higher in the finest detritus fraction relative to corresponding coarser fractions and bulk samples. The 87Sr/86Sr and εNd values of the finest fraction correspond with those of atmospheric dust originating from the Sahara Desert, while those of the coarse fractions are similar to loess deposits exposed in the Sinai and Negev Deserts. Pronounced excursions in the Sr-Nd-Pb isotope ratios toward more Sahara-like values coincide with the Heinrich (H) stadials 6, 5 and 1, reflecting significant increases in Saharan dust fluxes during regionally arid intervals, reflected by sharp lake level drops. Moreover, during H6 the dust came from different Saharan sources than during H1 and H5. While the relatively wet glacial climate in the Levant suppressed the transport of dust to the lake watershed, short-term hyper-arid spells during H-stadial intervals were accompanied by enhanced supply of fine Sahara dust to this region.
Hering, Johanna; Hille, Katja; Frömke, Cornelia; von Münchhausen, Christiane; Hartmann, Maria; Schneider, Bettina; Friese, Anika; Roesler, Uwe; Merle, Roswitha; Kreienbrock, Lothar
2014-09-01
A cross-sectional study concerning farm prevalence and risk factors for the count of cefotaxime resistant Escherichia coli (E. coli) (CREC) positive samples per sampling group on German fattening pig farms was performed in 2011 and 2012. Altogether 48 farms in four agricultural regions in the whole of Germany were investigated. Faecal samples, boot swabs and dust samples from two sampling groups per farm were taken and supplemental data were collected using a questionnaire. On 85% of the farms, at least one sample contained cefotaxime resistant E. coli colonies. Positive samples were more frequent in faeces (61%) and boot swabs (54%) than in dust samples (11%). Relevant variables from the questionnaire were analysed in a univariable mixed effect Poisson regression model. Variables that were related to the number (risk) of positive samples per sampling group with a p-value <0.2 were entered in a multivariable model. This model was reduced to statistically significant variables via backward selection. Factors that increased the risk for positive samples involved farm management and hygienic aspects. Farms that had a separate pen for diseased pigs had a 2.8 higher mean count of positive samples (95%-CI [1.71; 4.58], p=0.001) than farms without an extra pen. The mean count was increased on farms with under-floor exhaust ventilation compared to farms with over floor ventilation (2.22 [1.43; 3.46], p=0.001) and more positive samples were observed on farms that controlled flies with toxin compared to farms that did not (1.86 [1.24; 2.78], p=0.003). It can be concluded, that CREC are wide spread on German fattening pig farms. In addition the explorative approach of the present study suggests an influence of management strategies on the occurrence of cefotaxime resistant E. coli. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
2002-01-01
(Released 29 May 2002) The Science Today's THEMIS release captures Mangala Fossa. Mangala Fossa is a graben, which in geologic terminology translates into a long parallel to semi-parallel fracture or trough. Grabens are dropped or downthrown areas relative to the rocks on either side and these features are generally longer than they are wider. There are numerous dust devil trails seen in this image. In the lower portion of this image several dust devil tracks can be seen cutting across the upper surface then down the short stubby channel and finally back up and over to the adjacent upper surface. Some dust avalanche streaks on slopes are also visible. The rough material in the upper third of the image contains a portion of the rim of a 90 km diameter crater located in Daedalia Planum. The smooth crater floor has a graben (up to 7 km wide) and channel (2 km wide) incised into its surface. In the middle third and right of this image one can see ripples (possibly fossil dunes) on the crater floor material just above the graben. The floor of Mangala Fossa and the southern crater floor surface also have smaller linear ridges trending from the upper left to lower right. These linear ridges could be either erosional (yardangs) or depositional (dunes) landforms. The lower third of the scene contains a short stubby channel (near the right margin) and lava flow front (lower left). The floor of this channel is fairly smooth with some linear crevasses located along its course. One gets the impression that the channel floor is mantled with some type of indurated material that permits cracks to form in its surface. The Story In the Daedalia Plains on Mars, the rim of an old eroded crater rises up, a wreck of its former self (see context image at right). From the rough, choppy crater rim (top of the larger THEMIS image), the terrain descends to the almost smooth crater floor, gouged deeply by a trough, a channel, and the occasional dents of small, scattered craters. The deep trough running from southwest to northeast across the middle of this image is called 'Mangala Fossa.' Mangala Fossa is a graben, a land feature created by tectonic processes that worked to create a depression in the landscape. This graben is a little more than 4 miles wide at its maximum, but like most grabens, is much longer than it is wide. You can see from the context image that it runs across much of the width of the crater. Running southward from the graben (lower right-hand side of the larger THEMIS image) is a branching channel a little over a mile wide. The floor of this channel is fairly smooth with some linear crevasses along its course. These features suggest that the channel floor might be layered with some type of cemented material that permits cracks to form in its surface. Between the rough crater rim and the depressed graben, tiny crackles on the otherwise smooth surface appear. They might be the ripples of fossil dunes, hardened remains from a more active time. The floor of Mangala Fossa and the southern crater floor surface also feature small lines that seem to crease the surface. We know that they are ridges on the surface, but how did they form? Were higher surfaces carved away in grooves by the wind and scouring sand, forming ridges called yardangs? Or were dunes deposited on the smooth, lower terrain? No one knows for sure. Look closely for faint details as well. Do you see the subtle, scalloped pattern that laps at the lower left of the image, almost too muted to be seen? That's the sign of an ancient lava flow that stopped just there. And the shadowy gray streaks? Some are smudges caused by dust avalanches running down the slopes of the channel. Others are the tracks of dust devils that pass across the land, lifting and carrying away brighter dust to reveal the darker surface beneath. For a good example of a dust devil track, check out the faint gray line that cuts across the upper part of the channel, just below the point where it meets the graben.
Viegas, Carla; Faria, Tiago; Monteiro, Ana; Caetano, Liliana Aranha; Carolino, Elisabete; Quintal Gomes, Anita; Viegas, Susana
2017-12-27
Swine production has been associated with health risks and workers' symptoms. In Portugal, as in other countries, large-scale swine production involves several activities in the swine environment that require direct intervention, increasing workers' exposure to organic dust. This study describes an updated protocol for the assessment of occupational exposure to organic dust, to unveil an accurate scenario regarding occupational and environmental risks for workers' health. The particle size distribution was characterized regarding mass concentration in five different size ranges (PM0.5, PM1, PM2.5, PM5, PM10). Bioburden was assessed, by both active and passive sampling methods, in air, on surfaces, floor covering and feed samples, and analyzed through culture based-methods and qPCR. Smaller size range particles exhibited the highest counts, with indoor particles showing higher particle counts and mass concentration than outdoor particles. The limit values suggested for total bacteria load were surpassed in 35.7% (10 out of 28) of samples and for fungi in 65.5% (19 out of 29) of samples. Among Aspergillus genera, section Circumdati was the most prevalent (55%) on malt extract agar (MEA) and Versicolores the most identified (50%) on dichloran glycerol (DG18). The results document a wide characterization of occupational exposure to organic dust on swine farms, being useful for policies and stakeholders to act to improve workers' safety. The methods of sampling and analysis employed were the most suitable considering the purpose of the study and should be adopted as a protocol to be followed in future exposure assessments in this occupational environment.
Activation of human peroxisome-activated receptor-gamma (PPARy) by house dust extracts
Obesity in children has become an epidemic and recent research suggests a possible contribution from exposure to environmental chemicals. Several chemicals, such as phthalates, brominated flame retardants, and perfluorinated chemicals, are common in house dust on floors where chi...
Endotoxin Exposure: Predictors and Prevalence of Associated Asthma Outcomes in the United States
Mendy, Angelico; Metwali, Nervana; Salo, Päivi; Co, Caroll; Jaramillo, Renee; Rose, Kathryn M.; Zeldin, Darryl C.
2015-01-01
Rationale: Inhaled endotoxin induces airway inflammation and is an established risk factor for asthma. The 2005–2006 National Health and Nutrition Examination Survey included measures of endotoxin and allergens in homes as well as specific IgE to inhalant allergens. Objectives: To understand the relationships between endotoxin exposure, asthma outcomes, and sensitization status for 15 aeroallergens in a nationally representative sample. Methods: Participants were administered questionnaires in their homes. Reservoir dust was vacuum sampled to generate composite bedding and bedroom floor samples. We analyzed 7,450 National Health and Nutrition Examination Survey dust and quality assurance samples for their endotoxin content using extreme quality assurance measures. Data for 6,963 subjects were available, making this the largest study of endotoxin exposure to date. Log-transformed endotoxin concentrations were analyzed using logistic models and forward stepwise linear regression. Analyses were weighted to provide national prevalence estimates and unbiased variances. Measurements and Main Results: Endotoxin exposure was significantly associated with wheeze in the past 12 months, wheeze during exercise, doctor and/or emergency room visits for wheeze, and use of prescription medications for wheeze. Models adjusted for age, sex, race and/or ethnicity, and poverty-to-income ratio and stratified by allergy status showed that these relationships were not dependent upon sensitization status but were worsened among those living in poverty. Significant predictors of higher endotoxin exposures were lower family income; Hispanic ethnicity; participant age; dog(s), cat(s), cockroaches, and/or smoker(s) in the home; and carpeted floors. Conclusions: In this U.S. nationwide representative sample, higher endotoxin exposure was significantly associated with measures of wheeze, with no observed protective effect regardless of sensitization status. PMID:26258643
Breysse, Jill; Wendt, Jean; Dixon, Sherry; Murphy, Amy; Wilson, Jonathan; Meurer, John; Cohn, Jennifer; Jacobs, David E.
2011-01-01
Objective We examined the impact of a combination of home environmental interventions and nurse case management services on total settled dust loadings and on allergen concentrations in the homes of asthmatic children. Methods Using a randomized longitudinal controlled trial study design, we randomly assigned homes of asthmatic children in Milwaukee to either a control (n=64) or an intervention (n=57) group. Control group homes received a visual assessment, education, bed/pillow dust mite encasings, and treatment of lead-based paint hazards. The intervention group received these same services plus nurse case management that included tailored, individual asthma action plans, provision of minor home repairs, home cleaning using special vacuuming and wet washing, and integrated pest management. Dust vacuum samples were collected from measured surface areas of floors in the TV room, kitchen, and child's bedroom at baseline and at three-, six-, and 12-month follow-up visits. Dust loading (mass per surface area) is a means of measuring total dust and the total amount of allergen present. Results For the intervention group, geometric mean dust loadings declined significantly from baseline (39 milligrams per square foot [mg/ft2]) to post-intervention (11 mg/ft2) (p<0.001). Baseline dust loading, treatment group, visit, and season were significant predictors of follow-up dust loadings. Mean post-intervention dust loadings were 72% higher in the control group. The total amount of allergen in settled house dust declined significantly following the intervention because total dust loading declined; the concentration of allergens in settled dust did not change significantly. Conclusion The combination of nurse case management and home environmental interventions promotes collaboration between health and housing professionals and is effective in reducing exposures to allergens in settled dust. PMID:21563716
Sever, Michelle L; Arbes, Samuel J; Gore, J Chad; Santangelo, Richard G; Vaughn, Ben; Mitchell, Herman; Schal, Coby; Zeldin, Darryl C
2007-10-01
We previously reported significant reductions in cockroach allergen concentrations in urban homes by reducing cockroach infestations. To determine the effectiveness of pest control performed by professional entomologists, compared with commercial companies, in reducing cockroach allergen. This 3-arm randomized controlled trial enrolled 60 cockroach-infested homes in North Carolina. Homes were randomly assigned to a control group or 1 of 2 treatment groups. Treatment 1 had insecticide baits placed by entomologists from North Carolina State University. Treatment 2 received pest control from a randomly assigned commercial company. Vacuumed dust sampling and cockroach trapping were conducted at 0, 6, and 12 months. Dust samples were analyzed by ELISA. In treatment 1 homes, there were significant reductions in geometric mean trap counts compared with control and treatment 2 homes at 12 months. Relative to control, significant 12-month reductions in Bla g 1 were evident in treatment 1 homes at all sampled sites, except bedroom floor. From baseline to month 12, geometric mean Bla g 1 concentrations (U/g) decreased from 64.2 to 5.6 in kitchen, 10.6 to 1.1 in living room, 10.7 to 1.9 on bedroom floor, and 3.6 to 2.3 in bed. Treatment 2 homes showed no significant 12-month allergen reductions versus control. Reductions in Bla g 1 in cockroach-infested homes can be achieved by reducing infestations; however, the magnitude of allergen reduction is dependent on the thoroughness and effectiveness of cockroach eradication efforts. Elimination of cockroaches is an effective method for reducing exposure to cockroach allergen.
Leung, Anna O W; Zheng, Jinshu; Yu, Chik Kin; Liu, Wing Keung; Wong, Chris K C; Cai, Zongwei; Wong, Ming H
2011-07-01
Surface dust collected from printed circuit board recycling workshop floors, roads, a schoolyard, and an outdoor food market in Guiyu, China, a village intensely involved in e-waste processing, were investigated for levels of polybrominated diphenyl ethers (PBDEs) and polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). PBDE concentrations in dust from workshop-floors (14,800 ± 5130 ng/g) and on adjacent roads to the workshops (24,900 ± 31,600 ng/g) were highest among the study sites whereas PCDD/F concentrations were highest at the schoolyard (1316 pg/g) and in a workshop (1264 pg/g). Analyses of <2 mm and <53 μm dust particle sizes did not show any significant differences in PBDE concentrations. The cytotoxicity was investigated using two bioassays: 7-ethoxyresorufin O-deethylase (EROD-TEQ) and MTT. EROD-TEQ values ranged from 260 to 432 pg/g, with the highest in dust collected from a street lined with workshops. Using the MTT assay, cytoxicity of dust from the plastic chips drying district in Guiyu was higher than dust from the other sites investigated. This study showed that the primitive recycling of e-waste introduced toxic pollutants into the environment which are potentially harmful to the health of e-waste workers and local residents, especially children, and warrants an urgent investigation into POPs related health impacts.
Dzieciol, Monika; Schornsteiner, Elisa; Muhterem-Uyar, Meryem; Stessl, Beatrix; Wagner, Martin; Schmitz-Esser, Stephan
2016-04-16
Sanitation protocols are applied on a daily basis in food processing facilities to prevent the risk of cross-contamination with spoilage organisms. Floor drain water serves along with product-associated samples (slicer dust, brine or cheese smear) as an important hygiene indicator in monitoring Listeria monocytogenes in food processing facilities. Microbial communities of floor drains are representative for each processing area and are influenced to a large degree by food residues, liquid effluents and washing water. The microbial communities of drain water are steadily changing, whereas drain biofilms provide more stable niches. Bacterial communities of four floor drains were characterized using 16S rRNA gene pyrosequencing to better understand the composition and exchange of drain water and drain biofilm communities. Furthermore, the L. monocytogenes contamination status of each floor drain was determined by applying cultivation-independent real-time PCR quantification and cultivation-dependent detection according to ISO11290-1. Pyrosequencing of 16S rRNA genes of drain water and drain biofilm bacterial communities yielded 50,611 reads, which were clustered into 641 operational taxonomic units (OTUs), affiliated to 16 phyla dominated by Proteobacteria, Firmicutes and Bacteroidetes. The most abundant OTUs represented either product- (Lactococcus lactis) or fermentation- and food spoilage-associated phylotypes (Pseudomonas mucidolens, Pseudomonas fragi, Leuconostoc citreum, and Acetobacter tropicalis). The microbial communities in DW and DB samples were distinct in each sample type and throughout the whole processing plant, indicating the presence of indigenous specific microbial communities in each processing compartment. The microbiota of drain biofilms was largely different from the microbiota of the drain water. A sampling approach based on drain water alone may thus only provide reliable information on planktonic bacterial cells but might not allow conclusions on the bacterial composition of the microbiota in biofilms. Copyright © 2016. Published by Elsevier B.V.
Bla g 1 allergen levels in Zagreb area household dust.
Prester, Ljerka; Macan, Jelena
2011-03-01
Cockroach allergy is a health problem in many parts of the world. In urban environments, indoor exposure to cockroach allergens involves a risk of asthma. The aim of this study was to measure the mass fraction of Bla g 1, a major allergen of the German cockroach (Blatella germanica) in 30 house samples, collected at random from Zagreb area households, Croatia. Dust samples were collected on cellulose filters by vacuuming living rooms floors. After extraction, Bla g 1 was detected using the commercial enzyme-linked immunosorbent assay (ELISA). Only four of the thirty households had detectable Bla g 1 levels, and only in one was its concentration higher than 2.0 U g(-1), the threshold associated with sensitisation. The Bla g 1 ELISA proved highly sensitive, with the detection limit of 0.12 U g(-1). The within- and between-assay imprecision was 8.9 % and 14.4 %, respectively, and accuracy 85 % to 120 %. Low Bla g 1 levels in the household dust support previously reported low prevalence of skin sensitisation to B. germanica among Zagreb residents. Further monitoring should reveal if there are differences in cockroach allergen exposure and sensitisation between households from other geographic areas in Croatia.
Hazardous substances in indoor dust emitted from waste TV recycling facility.
Deng, Jingjing; Guo, Jie; Zhou, Xiaoyu; Zhou, Peng; Fu, Xiaoxu; Zhang, Wei; Lin, Kuangfei
2014-06-01
Various hazardous substances contained in waste TV sets might be released into environment via dust during recycling activities. Two brominated flame retardants (BFRs), polybrominated diphenyl ethers (PBDEs), and tetrabromobisphenol A (TBBPA), and five kinds of heavy metals (Cu, Pb, Cd, Cr, and Ni) were detected in indoor dust collected from two workshops (TV dismantling workshop and subsequent recycling workshop). PBDEs concentrations in dust from waste wires recycling line (722,000 ng/g) were the highest among the studied sites, followed by those in manual dismantling-sorting line (117,000 ng/g), whereas TBBPA concentrations were the highest in manual dismantling-sorting line (557 ng/g) and printed circuit board (PCB) recycling line (428 ng/g). For heavy metals, Cu and Pb were the most enriched metals in all dust samples. The highest concentration of Pb (22,900 mg/kg) was found in TV dismantling workshop-floor dust. Meanwhile, Cu was the predominant metal in dust from the PCB recycling line, especially in dust collected from electrostatic separation area (42,700 mg/kg). Occupational exposure assessment results showed that workers were the most exposed to BDE-209 among the four PBDE congeners (BDE-47, BDE-99, BDE-153, and BDE-209) in both workshops. The hazard quotient (HQ) indicated that noncancerous effects were unlikely for both BFRs and heavy metals (HQ < 1), and carcinogenic risks for Cd, Cr, and Ni (risk < 10(-6)) on workers in two workshops were relatively low.
Shahan, M.R.; Seaman, C.E.; Beck, T.W.; Colinet, J.F.; Mischler, S.E.
2017-01-01
Float coal dust is produced by various mining methods, carried by ventilating air and deposited on the floor, roof and ribs of mine airways. If deposited, float dust is re-entrained during a methane explosion. Without sufficient inert rock dust quantities, this float coal dust can propagate an explosion throughout mining entries. Consequently, controlling float coal dust is of critical interest to mining operations. Rock dusting, which is the adding of inert material to airway surfaces, is the main control technique currently used by the coal mining industry to reduce the float coal dust explosion hazard. To assist the industry in reducing this hazard, the Pittsburgh Mining Research Division of the U.S. National Institute for Occupational Safety and Health initiated a project to investigate methods and technologies to reduce float coal dust in underground coal mines through prevention, capture and suppression prior to deposition. Field characterization studies were performed to determine quantitatively the sources, types and amounts of dust produced during various coal mining processes. The operations chosen for study were a continuous miner section, a longwall section and a coal-handling facility. For each of these operations, the primary dust sources were confirmed to be the continuous mining machine, longwall shearer and conveyor belt transfer points, respectively. Respirable and total airborne float dust samples were collected and analyzed for each operation, and the ratio of total airborne float coal dust to respirable dust was calculated. During the continuous mining process, the ratio of total airborne float coal dust to respirable dust ranged from 10.3 to 13.8. The ratios measured on the longwall face were between 18.5 and 21.5. The total airborne float coal dust to respirable dust ratio observed during belt transport ranged between 7.5 and 21.8. PMID:28936001
Dust Studies in DIII-D and TEXTOR
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rudakov, D L; Litnovsky, A; West, W P
2009-02-17
Studies of naturally occurring and artificially introduced carbon dust are conducted in DIII-D and TEXTOR. In DIII-D, dust does not present operational concerns except immediately after entry vents. Submicron sized dust is routinely observed using Mie scattering from a Nd:Yag laser. The source is strongly correlated with the presence of Type I edge localized modes (ELMs). Larger size (0.005-1 mm diameter) dust is observed by optical imaging, showing elevated dust levels after entry vents. Inverse dependence of the dust velocity on the inferred dust size is found from the imaging data. Direct heating of the dust particles by the neutralmore » beam injection (NBI) and acceleration of dust particles by the plasma flows are observed. Energetic plasma disruptions produce significant amounts of dust. Large flakes or debris falling into the plasma may result in a disruption. Migration of pre-characterized carbon dust is studied in DIII-D and TEXTOR by introducing micron-size dust in plasma discharges. In DIII-D, a sample holder filled with {approx}30 mg of dust is introduced in the lower divertor and exposed to high-power ELMing H-mode discharges with strike points swept across the divertor floor. After a brief exposure ({approx}0.1 s) at the outer strike point, part of the dust is injected into the plasma, raising the core carbon density by a factor of 2-3 and resulting in a twofold increase of the radiated power. In TEXTOR, instrumented dust holders with 1-45 mg of dust are exposed in the scrape-off layer 0-2 cm radially outside of the last closed flux surface in discharges heated with neutral beam injection (NBI) power of 1.4 MW. At the given configuration of the launch, the dust did not penetrate the core plasma and only moderately perturbed the edge plasma, as evidenced by an increase of the edge carbon content.« less
Wu, J; Liu, Z G; Ran, P X; Wang, B
2009-12-01
To investigate mites in the dust of air-conditioner filters (MACF) in China, a total of 652 dust samples were collected from six cities: Guangzhou (n = 129), Nanchang (n = 127), Shanghai (n = 113), Xian (n = 93), Beijing (n = 93), and Shenyang (n = 79). Tarsonemus granarius was the most dominant species (87.2%). Dermatophagoides pteronyssinus and Dermatophagoides farinae only represented 7.0 and 3.0% of total mites, respectively. With latitude increasing, both mite occurrence rate (P < 0.001) and density (mites/g dust) (P < 0.001) were significantly decreasing. Multivariate regression analysis suggested that the annual average temperature and minimum temperature in different cities had dominant influences on MACF density. The logistic regression analysis revealed that the presence of MACF was positively associated with air-conditioner age, utilization time and power. Wall and window type air-conditioner had higher risk of finding MACF than the floor type air-conditioner. As far as the cleaning interval time of ACF was concerned, higher risk ratio and the highest density of MACF were found in the time stage of >3, < or =12 months. It was also suggested that house type could influence the presence of MACF. A negative association between the house floor and the MACF prevalence was found as well. Mites present in the dust of air-conditioner filters are potential indoor threat to asthma and allergy sufferers. In this study, we find that the storage mite Tarsonemus granarius is the predominant species of mites in the dust of air-conditioner filters (MACF). Thus, the possible clinical importance of T. granarius should cause more our attentions in the future. The abundance and distribution of MACF are also found significantly varied in different climatic regions of China. When we try to assess the possible risk of MACF, more attentions should be focused on subtropical region than temperate region. The influence analysis of environmental characteristics on the prevalence of MACF will shed light on the establishment of mite control strategy and the design of mite defense air-conditioner.
NASA Astrophysics Data System (ADS)
Salonen, Heidi; Duchaine, Caroline; Létourneau, Valérie; Mazaheri, Mandana; Laitinen, Sirpa; Clifford, Sam; Mikkola, Raimo; Lappalainen, Sanna; Reijula, Kari; Morawska, Lidia
2016-10-01
As endotoxin exposure has known effects on human health, it is important to know the generally existing levels of endotoxins as well as their contributing factors. This work reviews current knowledge on the endotoxin loads in settled floor dust, concentrations of endotoxins in indoor air, and different environmental factors potentially affecting endotoxin levels. The literature review consists of peer-reviewed manuscripts located using Google and PubMed, with search terms based on individual words and combinations. References from relevant articles have also been searched. Analysis of the data showed that in residential, school, and office environments, the mean endotoxin loads in settled floor dust varied between 660 and 107,000 EU/m2, 2180 and 48,000 EU/m2, and 2700 and 12,890 EU/m2, respectively. Correspondingly, the mean endotoxin concentrations in indoor air varied between 0.04 and 1610 EU/m3 in residences, and 0.07 and 9.30 EU/m3 in schools and offices. There is strong scientific evidence indicating that age of houses (or housing unit year category), cleaning, farm or rural living, flooring materials (the presence of carpets), number of occupants, the presence of dogs or cats indoors, and relative humidity affect endotoxin loads in settled floor dust. The presence of pets (especially dogs) was extremely strongly associated with endotoxin concentrations in indoor air. However, as reviewed articles show inconsistency, additional studies on these and other possible predicting factors are needed.
[Mites in mattress dust and relevant environmental factors in student dormitories in Shenzhen].
Wang, Bin; Wu, Jie; Liu, Zhi-gang; Ran, Pi-xin; Gao, Qiao; Luo, Chun-hui; Ai, Mei
2009-02-28
Three hundred and eight mattress dust samples were collected from college dormitories in Shenzhen with a mite prevalence of 88% (271/308). From the samples, 6163 mites were isolated and identified. Dermatophagoides farinae, D. pteronyssinus and Blomia tropicalis were three most abundant species, occupying 29.7%, 21.7% and 17.9%, respectively. It was found that sex of the students, mattress cover (bamboo mat or bed sheet), with or without air conditioner installation, and daily using of air conditioner (<2 h, 2-8 h and >8 h) had no significant influence on the mite prevalence (P>0.05). However, logistic regression analysis revealed that the risk of mite sensitization in male student dormitory was significantly lower than that in female dormitory (OR=0.55, P=0.038), and the risk of using bed sheets was significantly higher than using bamboo mats (OR=2.13, P=0.040). Both mite prevalence and the risk of mite sensitization significantly decreased with higher floor of the dormitory building.
12. BUILDING 621, INTERIOR, GROUND FLOOR, LOOKING NORTHWEST AT SCREENING ...
12. BUILDING 621, INTERIOR, GROUND FLOOR, LOOKING NORTHWEST AT SCREENING MACHINE THAT REMOVES SHELL FRAGMENTS. METALLIC DUST REMOVED BY MAGNETIC SEPERATOR UNDERNEATH SCREEN. SAWDUST IS RETURNED TO SAWDUST HOPPER BY ELEVATOR. HOODS OVER SCREENING MACHINE AT WORKBENCH REMOVE FINE SAWDUST. - Picatinny Arsenal, 600 Area, Test Areas District, State Route 15 near I-80, Dover, Morris County, NJ
Foarde, Karin; Berry, Michael
2004-01-01
Choosing the appropriate floor surface for a school environment is a complex issue. To assist school personnel in determining which flooring is best for their school, we studied the biocontaminant levels associated with carpeted and hard surface flooring. Two schools were selected, one predominantly tiled and one predominantly carpeted, as similar as possible with the exception of their floor coverings. Neither school was a "problem" building. Multiple biocontaminants were measured. For flooring, there were statistically significant differences for all the tested biocontaminants except fungi. The carpeted surfaces, being strong sinks, generally had higher surface loadings of the biocontaminants, while the airborne levels were significantly higher over tiled floors. Significant differences in airborne levels were found for dust mass, spores, fungi, beta-1,3 glucans, and endotoxins. The results suggest that carpet flooring was not the major contributor to airborne levels of biocontaminants in these two nonproblem schools.
Indoor dust and air concentrations of endotoxin in urban and rural environments.
Barnig, C; Reboux, G; Roussel, S; Casset, A; Sohy, C; Dalphin, J-C; de Blay, F
2013-03-01
Rural dairy farming is associated with high exposure to indoor endotoxins as compared to rural nonfarming houses and urban houses. The time spent on the mattress (7 h for an adult) and of the proximity of the contaminated source should be taken into account with the other causes of exposure. Studies in European children from a farming background have shown that these children have a reduced risk of asthma and atopic sensitization compared to their urban counterparts. It has been suggested that this might be due to exposure to high levels of endotoxin in the farming environment. The aim of this study was to compare indoor endotoxin concentrations in air and dust samples from randomly selected urban and rural dwellings. In the rural area, endotoxins were analysed in farmhouses and nonfarmhouses as well as housing characteristics, lifestyle factors and agricultural practices likely to influence air and dust endotoxin levels. Endotoxin levels were significantly higher in floor (6600 ± 6100 vs 3600 ± 5600 and 3800 ± 17,000 ng g⁻¹; P < 0·001) and mattress dust (2900 ± 4100 vs 1100 ± 2400 and 800 ± 2600 ng g⁻¹; P < 0·001) from farmhouses compared to other rural and urban homes. However, no difference was observed between endotoxin concentrations in the air of urban and rural houses, and airborne endotoxin levels did not correlate to dust levels. Lack of ventilation and direct entry into the house were correlated with an increase in dust endotoxin levels. These results confirm that dairy farming is associated with high exposure to endotoxins in indoor dust samples. No difference was observed between indoor airborne concentrations between urban and rural houses. These results suggest that measuring endotoxin in dust is the most relevant method to assess endotoxin exposure. © 2012 The Society for Applied Microbiology.
Temporal variation of indoor air quality in an enclosed swine confinement building.
O'Shaughnessy, P T; Achutan, C; Karsten, A W
2002-11-01
Human health hazards can exist in swine confinement buildings due to poor indoor air quality (IAQ). During this study, airborne dust and ammonia concentrations were monitored within a working farrowing facility as indicators of IAQ. The purposes of this study were to assess the temporal variability of the airborne dust and ammonia levels over both a daily and seasonal basis, and to determine the accuracy of real-time sensors relative to actively sampled data. An ammonia sensor, aerosol photometer, indoor relative humidity sensor, and datalogger containing an indoor temperature sensor were mounted on a board 180 cm above the floor in the center of a room in the facility. Sensor readings were taken once every 4 minutes during animal occupancy (3-week intervals). Measurements of total and respirable dust concentrations by standard method, aerosol size distribution, and ammonia concentrations were taken once per week, in addition to temperature and relative humidity measurements using a thermometer and sling psychrometer, respectively. Samples were taken between September 1999 and August 2000. Diurnal variations in airborne dust revealed an inverse relationship with changes in indoor temperature and, by association, changes in airflow rate. Ammonia levels changed despite relatively stable internal temperatures. This change may be related to both changes in flow rates and in volatility rates. As expected, contaminant concentrations increased during the cold weather months, but these differences were not significantly different from other seasons. However, total dust concentrations were very low (geometric mean = 0.8 mg/m3) throughout the year. Likewise, ammonia concentrations averaged only 3.6 ppm in the well-maintained study site.
2015-02-12
This image captured by NASA 2001 Mars Odyssey spacecraft is of an unnamed crater in Noachis Terra. Part of the crater floor contains a dune field. Dust devil tracks are visible east of the dunes. Orbit Number: 57931 Latitude: -52.1733 Longitude: 18.0624 Instrument: VIS Captured: 2015-01-04 18:28 http://photojournal.jpl.nasa.gov/catalog/PIA19199
14. INTERIOR VIEW OF THIRD FLOOR OF FACTORY ADDITION, NORTHWEST ...
14. INTERIOR VIEW OF THIRD FLOOR OF FACTORY ADDITION, NORTHWEST CORNER OF BUILDING. AT THE CENTER IS THE BUFFING MACHINE, MANUFACTURED BY THE ACME CO. OF DETROIT, MICHIGAN. IT WAS HERE THAT ALUMINUM WARES WERE BROUGHT FOR FINAL GRINDING AND BUFFING. THE HOSES REMOVED DUST AND DEBRIS. - Illinois Pure Aluminum Company, 109 Holmes Street, Lemont, Cook County, IL
Microanalytical study of some cosmic dust discovered in sea-floor sediments in China
NASA Technical Reports Server (NTRS)
Shijie, Z.; Hanchang, P.; Zhong, Y.
1984-01-01
The study of cosmic dust can provide useful data in the investigation of the origin of the Earth and the evolution of celestial bodies. Three types of cosmic dust (ferriginous, siliceous, and glassy) were discovered in the seafloor sediments near China. Their chemical composition and microstructure were examined by X-ray diffraction, fractography, and electron microscopy. The major mineral in an iron-containing cosmic dust is magnetite. The silicate spheres contain sundry metals and metal oxides. Glassy microtektites are similar in composition to tektites, and are found in all the major meteorite areas worldwide.
Predictors of Airborne Endotoxin Concentrations in Inner City Homes
Mazique, D; Diette, GB; Breysse, PN; Matsui, EC; McCormack, MC; Curtin-Brosnan, J; Williams, D; Peng, RD; Hansel, NN
2011-01-01
Few studies have assessed in-home factors which contribute to airborne endotoxin concentrations. In 85 inner-city Baltimore homes, we found no significant correlation between settled dust and airborne endotoxin concentrations. Certain household activities and characteristics, including frequency of dusting, air conditioner use and type of flooring, explained 36–42% of the variability of airborne concentrations. Measurements of both airborne and settled dust endotoxin concentrations may be needed to fully characterize domestic exposure in epidemiologic investigations. PMID:21429483
NASA Technical Reports Server (NTRS)
2004-01-01
31 January 2004 This Mars Global Surveyor (MGS) Mars Orbiter Camera (MOC) image shows a dark sand dune patch that occurs on the floor of a southern hemisphere crater near 64.1oS, 197.2oW. Passing dust devils have disrupted the fine, bright dust that coats the surrounding terrain, leaving wildly-varied streak patterns. Dark dots to the left (west) of the dune are boulders. The picture covers an area 3 km (1.9 mi) wide; sunlight illuminates the scene from the upper left.
Mining cosmic dust from the blue ice lakes of Greenland
NASA Technical Reports Server (NTRS)
Maurette, M.; Brownlee, D. E.; Fehrenback, L.; Hammer, C.; Jehano, C.; Thomsen, H. H.
1985-01-01
Extraterrestrial material, most of which invisible settles to Earth's surface as dust particles smaller than a millimeter in size were investigated. Particles of 1/10 millimeter size fall at a rate of one/sq m/yr collection of extraterrestrial dust is important because the recovered cosmic dust particles can provide important information about comets. Comets are the most important source of dust in the solar system and they are probably the major source of extraterrestrial dust that is collectable at the Earth's surface. A new collection site for cosmic dust, in an environment where degradation by weathering is minimal is reported. It is found that the blue ice lakes on the Greenland ice cap provide an ideal location for collection of extraterrestrial dust particles larger than 0.1 mm in size. It is found that the lakes contain large amounts of cosmic dust which is much better preserved than similar particles recovered from the ocean floor.
Fungal and Bacterial Communities in Indoor Dust Follow Different Environmental Determinants.
Weikl, Fabian; Tischer, Christina; Probst, Alexander J; Heinrich, Joachim; Markevych, Iana; Jochner, Susanne; Pritsch, Karin
2016-01-01
People spend most of their time inside buildings and the indoor microbiome is a major part of our everyday environment. It affects humans' wellbeing and therefore its composition is important for use in inferring human health impacts. It is still not well understood how environmental conditions affect indoor microbial communities. Existing studies have mostly focussed on the local (e.g., building units) or continental scale and rarely on the regional scale, e.g. a specific metropolitan area. Therefore, we wanted to identify key environmental determinants for the house dust microbiome from an existing collection of spatially (area of Munich, Germany) and temporally (301 days) distributed samples and to determine changes in the community as a function of time. To that end, dust samples that had been collected once from the living room floors of 286 individual households, were profiled for fungal and bacterial community variation and diversity using microbial fingerprinting techniques. The profiles were tested for their association with occupant behaviour, building characteristics, outdoor pollution, vegetation, and urbanization. Our results showed that more environmental and particularly outdoor factors (vegetation, urbanization, airborne particulate matter) affected the community composition of indoor fungi than of bacteria. The passage of time affected fungi and, surprisingly, also strongly affected bacteria. We inferred that fungal communities in indoor dust changed semi-annually, whereas bacterial communities paralleled outdoor plant phenological periods. These differences in temporal dynamics cannot be fully explained and should be further investigated in future studies on indoor microbiomes.
Fungal and Bacterial Communities in Indoor Dust Follow Different Environmental Determinants
Weikl, Fabian; Tischer, Christina; Probst, Alexander J.; Heinrich, Joachim; Markevych, Iana; Jochner, Susanne; Pritsch, Karin
2016-01-01
People spend most of their time inside buildings and the indoor microbiome is a major part of our everyday environment. It affects humans’ wellbeing and therefore its composition is important for use in inferring human health impacts. It is still not well understood how environmental conditions affect indoor microbial communities. Existing studies have mostly focussed on the local (e.g., building units) or continental scale and rarely on the regional scale, e.g. a specific metropolitan area. Therefore, we wanted to identify key environmental determinants for the house dust microbiome from an existing collection of spatially (area of Munich, Germany) and temporally (301 days) distributed samples and to determine changes in the community as a function of time. To that end, dust samples that had been collected once from the living room floors of 286 individual households, were profiled for fungal and bacterial community variation and diversity using microbial fingerprinting techniques. The profiles were tested for their association with occupant behaviour, building characteristics, outdoor pollution, vegetation, and urbanization. Our results showed that more environmental and particularly outdoor factors (vegetation, urbanization, airborne particulate matter) affected the community composition of indoor fungi than of bacteria. The passage of time affected fungi and, surprisingly, also strongly affected bacteria. We inferred that fungal communities in indoor dust changed semi-annually, whereas bacterial communities paralleled outdoor plant phenological periods. These differences in temporal dynamics cannot be fully explained and should be further investigated in future studies on indoor microbiomes. PMID:27100967
Malcoe, Lorraine Halinka; Lynch, Robert A; Keger, Michelle Crozier; Skaggs, Valerie J
2002-04-01
Lead poisoning prevention requires knowledge of lead sources and of appropriate residential lead standards. Data are severely lacking on lead sources for Native American children, many of whom live in rural areas. Further, the relation of mining waste to blood lead concentrations (BPbs) of rural children is controversial. In collaboration with the eight tribes of northeastern Oklahoma, we assessed lead sources and their effects on BPbs for rural Native American and White children living in a former mining region. Venous blood lead, residential environmental (soil, dust, paint, water), and caregiver interview (e.g., hand-to-mouth behaviors, socioeconomic conditions) data were obtained from a representative sample of 245 children 1-6 years of age. BPbs ranged from 1 to 24 microg/dL. There were no ethnic differences in BPbs (p= 0.48) nor any patterns of excess lead sources for Native American or White children. Multiple linear regression analyses indicated that mean soil lead, mean floor lead loading, mouthing behaviors, caregivers' education, and residence in former mining towns were all strongly associated with BPbs. Logistic regression results showed mean floor dust lead loading greater than or equal to 10.1 microg/ft(2) (odds ratio [OR], 11.4; 95% confidence interval [CI], 3.5-37.3), and yard soil lead >165.3 mg/kg (OR, 4.1; CI, 1.3-12.4) were independently associated with BPbs greater than or equal to 10 microg/dL. We also found strong interactions between soil lead and poverty (p= 0.005), and dust and soil sources (p= 0.02). Our findings indicate that soil and dust lead derived largely from mining waste pose a health hazard to Native American and White children, and that current residential dust lead standards are insufficient to adequately protect children. Moreover, our finding that poor children are especially vulnerable to lead exposures suggests that residential standards should consider interactions among socioeconomic conditions and lead sources if environmental justice is to be achieved.
Wouters, Inge M.; Douwes, Jeroen; Doekes, Gert; Thorne, Peter S.; Brunekreef, Bert; Heederik, Dick J. J.
2000-01-01
As part of environmental management policies in Europe, separate collection of organic household waste and nonorganic household waste has become increasingly common. As waste is often stored indoors, this policy might increase microbial exposure in the home environment. In this study we evaluated the association between indoor storage of organic waste and levels of microbial agents in house dust. The levels of bacterial endotoxins, mold β(1→3)-glucans, and fungal extracullar polysaccharides (EPS) of Aspergillus and Penicillium species were determined in house dust extracts as markers of microbial exposure. House dust samples were collected in 99 homes in The Netherlands selected on the basis of whether separated organic waste was present in the house. In homes in which separated organic waste was stored indoors for 1 week or more the levels of endotoxin, EPS, and glucan were 3.2-, 7.6-, and 4.6-fold higher, respectively (all P < 0.05), on both living room and kitchen floors than the levels in homes in which only nonorganic residual waste was stored indoors. Increased levels of endotoxin and EPS were observed, 2.6- and 2.1-fold (P < 0.1), respectively, when separated organic waste was stored indoors for 1 week or less, whereas storage of nonseparated waste indoors had no effect on microbial agent levels (P > 0.2). The presence of textile floor covering was another major determinant of microbial levels (P < 0.05). Our results indicate that increased microbial contaminant levels in homes are associated with indoor storage of separated organic waste. These increased levels might increase the risk of bioaerosol-related respiratory symptoms in susceptible people. PMID:10653727
[Dust mites as occupational allergens in two bakeries of La Habana, Cuba].
Fernández-Duro, Bárbara I; Alvarez-Castelló, Mirta; Mateo-Morejón, Mayteé; Luis-Rodríguez, Bárbara; Labrada-Rosado, Alexis
2014-01-01
Occupational allergies are becoming more frequent. The allergens present in the working environment of bakeries, such as mites, are not well identified despite being known risk factors of respiratory diseases. To isolate and identify the species of mites present in two bakeries in La Habana, Cuba, with high sensitization of mites on their workers. A descriptive study was done in which samples were taken by tripled from potential sources of mites in bakeries -as flourin use, spills of wheat on the floors, wheat flour stored in sealed bags, sugar, yeast, granulated baker- that were processed, according to the method of flotation of Hart and Fain (1987) to isolate, identify and count the mites present. Mites were found in samples of wheat flourin use, spills on the floorsand in the wheat flourstored in sealed bags. The species identified were Blomia tropicalis (70%), Tyrophagus putrescentiae (20%) and to a lesser degree Dermatophagoides pteronyssinus and Dermatophagoides siboney. There is a high exposure to house dust mites, particularly to store mites, which constitute a risk factor of occupational allergy to consider.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-16
... lead in dust on floors and window sills in such housing and in pre-1978 child-occupied facilities below... window troughs of 400 mg/ft2 (40 CFR 45.227(e)(8)(viii), and 24 CFR 35.1320(b)(2)(i)). The HUD Secretary... levels for floors and window sills are the same as the lead hazard standards. This survey will question...
NASA Astrophysics Data System (ADS)
Wang, Longlong; Gregorič, Asta; Stanič, Samo; Mole, Maruška; Bergant, Klemen; Močnik, Griša; Drinovec, Luka; Vaupotič, Janja; Miler, Miloš; Gosar, Mateja
2017-04-01
Atmospheric aerosols influence Earth's radiation budget, visibility and air quality, as well as the cloud formation processes and precipitation. The structure of the vertical aerosol distribution, in particular that of black carbon, significantly influences the aerosol direct radiative effect, followed by feedbacks on cloud and planetary boundary layer dynamics. The knowledge on aerosol vertical distribution and properties therefore provides an important insight into many atmospheric processes. In order to retrieve the vertical distribution of aerosol properties in the Vipava valley (Slovenia) and the influence of planetary boundary layer height on the local air quality, in-situ and LIDAR measurements were performed. In-situ methods consisted of aerosol size distribution and number concentration and black carbon concentration measurements which were performed during a one-month extensive measurement campaign in spring 2016. Aerosol size distribution (10 nm to 30 µm) was measured at the valley floor using scanning mobility particle sizer (SMPS, Grimm Aerosol Technique, Germany) and optical particle counter (OPC, Grimm Aerosol Technique, Germany). Black carbon concentrations were measured by Aethalometer AE33 (Aerosol d.o.o., Slovenia) at the valley floor (125 m a.s.l.) and at the top of the adjacent mountain ridge (951 m a.s.l.), the later representing regional background conditions. The in-situ measurements were combined with LIDAR remote sensing, where the vertical profiles of aerosol backscattering coefficients were retrieved using the Klett method. In addition, aerosol samples were analyzed by SEM-EDX to obtain aerosol morphology and chemical composition. Two different cases with expected dominant presence of specific aerosol types were investigated in more detail. They show significantly different aerosol properties and distributions within the valley, which has an important implication for the direct radiative effect. In the first case, during a Saharan dust event on 5-6 April 2016 the prevailing aerosols were expected to be mineral dust, while in the second case, during traditional bonfires on 30 April 30 - 1 May 2016 carbonaceous aerosol from biomass burning prevailed. In the Saharan dust case, the height of the mineral dust layer decreased from 2 km to 1 km, causing the mixing of mineral dust within the planetary boundary layer, which resulted in its spreading within the valley. Increased fraction of relatively large mineral aerosols was observed (2.5-10 µm) and their identity was confirmed by SEM-EDX analysis of the collected samples. No significant increase of black carbon concentration was detected, indicating dry deposition of mineral dust and good mixing with the locally emitted black carbon. In the biomass burning case, the LIDAR backscattering coefficient gradually increased due to intensive local emissions within the valley. After 10PM the increasing wind caused the dispersion of aerosols and the total particle concentration of particles smaller than 1 µm indicates smaller sizes of black carbon aerosols in comparison to mineral dust particles.
Are nursery schools and kindergartens safe for our kids? The Hong Kong study.
Tong, S T; Lam, K C
1998-05-27
Pediatric heavy metal (particularly lead) poisoning is a widespread, yet preventable problem in many parts of the world. Interior floor dust is found to be one of the major pathways of childhood exposure. However, school and health authorities in most countries do not have any stipulations nor guidelines in regulating heavy metal contamination in floor dusts in schools. This study attempts to examine the level of heavy metal contamination in 53 nursery schools and kindergartens in Hong Kong and study its relationship with the environmental factors. The results of this study reveal that the arithmetic mean level of lead in exterior dust is 280.01 mg/kg, with a minimum level of 48.80 mg/kg and a maximum of 2108.31 mg/kg, which is somewhat lower than other studies, such as those reported by Chan et al. (Biomed. Environ. Sci. 1989;2:131-140) and Akhter and Madany (Water Air Soil Pollut. 1993;66:111-119), but those of the manganese (mean = 532.16 mg/kg, range = 102.51-1736.25 mg/kg) and zinc levels (mean = 2694.23 mg/kg, range = 898.33-9899.85 mg/kg) are much higher. Out of the 10 districts examined, Kwun Tong and North Point are found to be the most polluted. They are older districts with polluting industries and heavy traffic. The results of the analysis of variance suggest that the heavy metal particulate may originate from the exterior. Auto-vehicles are a likely source. The toxins are blown inside through the opened windows. Other factors that may affect the content of metal in floor dusts are the time since the school was last painted, the age of the housing complex, the condition of the school and the use of vacuum cleaners.
Aeolian processes in Proctor Crater on Mars: Sedimentary history as analyzed from multiple data sets
Fenton, L.K.; Bandfield, J.L.; Ward, A.W.
2003-01-01
Proctor Crater is a 150 km diameter crater in Noachis Terra, within the southern highlands of Mars. The analysis leading to the sedimentary history incorporates several data sets including imagery, elevation, composition, and thermal inertia, mostly from the Mars Global Surveyor mission. The resulting stratigraphy reveals that the sedimentary history of Proctor Crater has involved a complex interaction of accumulating and eroding sedimentation. Aeolian features spanning much of the history of the crater interior dominate its surface, including large erosional pits, stratified beds of aeolian sediment, sand dunes, erosional and depositional streaks, dust devil tracks, and small bright bed forms that are probably granule ripples. Long ago, up to 450 m of layered sediment filled the crater basin, now exposed in eroded pits on the crater floor. These sediments are probably part of an ancient deposit of aeolian volcaniclastic material. Since then, some quantity of this material has been eroded from the top layers of the strata. Small, bright dune forms lie stratigraphically beneath the large dark dune field. Relative to the large dark dunes, the bright bed forms are immobile, although in places, their orientations are clearly influenced by the presence of the larger dunes. Their prevalence in the crater and their lack of compositional and thermal distinctiveness relative to the crater floor suggests that these features were produced locally from the eroding basin fill. Dust devil tracks form during the spring and summer, following a west-southwesterly wind. Early in the spring the dust devils are largely restricted to dark patches of sand. As the summer approaches, dust devil tracks become more plentiful and spread to the rest of the crater floor, indicating that the entire region acquires an annual deposit of dust that is revealed by seasonal dust devils. The dark dunes contain few dust devil tracks, suggesting that accumulated dust is swept away directly by saltation, rather than by the passage of dust devils. Spectral deconvolution indicates that the dark dunes have infrared spectra consistent with basalt-like materials. The average thermal inertia calculated from Thermal Emission Spectrometer bolometric temperatures is 277 ?? 17 J m-2 s-0.5 K-1, leading to an effective grain size of 740 ?? 170 ??m, which is consistent with coarse sand and within the range expected for Martian sand. The coarse sand that composes the large dune field may have originated from outside the crater, saltating in from the southwest. Most of the transport pathway that delivered this sand to the dune field has since been eroded away or buried. The sand was transported to the east center of the crater floor, where beneath the present-day dunes a 50 m high mound of sand has accumulated. Dune slip faces indicate a wind regime consisting of three opposing winds. Some of these wind directions are correlated with the orientations of dust devil tracks and bright bed forms. The combination of a tall mound of sand and three opposing winds is consistent with a convergent wind regime, which produces the large reversing transverse and star dunes that dominate the dune field. The dark dunes have both active slip faces and seemingly inactive slip faces, suggesting that the dunes vary spatially in their relative activity. Nevertheless, the aeolian activity that has dominated the history of Proctor Crater still continues today. Copyright 2003 by the American Geophysical Union.
NASA Technical Reports Server (NTRS)
2003-01-01
MGS MOC Release No. MOC2-363, 17 May 2003
This summertime Mars Global Surveyor (MGS) Mars Orbiter Camera (MOC) view of the floor of Argyre Basin shows a plethora of dark streaks thought to have been created by the passage of dust devils. Dust devils are vortices of wind--just as a tornado is a vortex of wind associated with stormy weather on Earth, and the spiraling of water down a bathtub drain is a vortex in a liquid. Dust devils usually form on Mars on relatively calm, quiet, spring and summer afternoons. The passage of a dust devil picks up and disturbs the thin coatings of dust on the martian surface, forming streaks that mark the path that the moving dust devil took. This picture covers an area 3 km (1.9 mi) wide and is located near 48.5oS, 43.0oW. Sunlight illuminates the scene from the upper left.Asthma and the hygiene hypothesis. Does cleanliness matter?
Weber, Juliane; Illi, Sabina; Nowak, Dennis; Schierl, Rudolf; Holst, Otto; von Mutius, Erika; Ege, Markus J
2015-03-01
The early hygiene hypothesis explained the development of allergies by a lack of infections; nowadays, the aspect of excessive cleanliness in affluent populations seems to have replaced this concept. Yet, no investigation has shown that home or personal cleanliness relate to allergic diseases. To relate personal and home cleanliness to risk of asthma and allergies. Comprehensive questionnaire information on home or personal cleanliness and allergic health conditions at school age was collected in 399 participants of the urban Perinatale Asthma Umwelt Langzeit Allergie Studie (PAULA) birth cohort. Bacterial markers were assessed in floor and mattress dust and were related to cleanliness and allergic diseases. Personal cleanliness was inversely related to bacterial compounds on floors and mattresses, whereas home cleanliness effectively reduced dust amount but not microbial markers. Exposure to muramic acid related to a lower prevalence of school-age asthma (adjusted odds ratio, 0.59 [95% confidence interval, 0.39; 0.90]). Mattress endotoxin in the first year of life was inversely associated with atopic sensitization (0.73 [0.56-0.96]) and asthma at school age (0.72 [0.55-0.95]). Despite the associations of dust parameters both with cleanliness and allergic health conditions, the development of allergies was not related to home and personal cleanliness. Bacterial exposure in house dust determined childhood asthma and allergies. Personal cleanliness, such as washing hands, and home cleanliness were objectively reflected by dust parameters in homes. However, neither personal nor home cleanliness was associated with a risk for asthma and allergies. Other microbial components in house dust not affected by personal hygiene are likely to play a role.
Faria, Tiago; Monteiro, Ana; Carolino, Elisabete; Quintal Gomes, Anita
2017-01-01
Swine production has been associated with health risks and workers’ symptoms. In Portugal, as in other countries, large-scale swine production involves several activities in the swine environment that require direct intervention, increasing workers’ exposure to organic dust. This study describes an updated protocol for the assessment of occupational exposure to organic dust, to unveil an accurate scenario regarding occupational and environmental risks for workers’ health. The particle size distribution was characterized regarding mass concentration in five different size ranges (PM0.5, PM1, PM2.5, PM5, PM10). Bioburden was assessed, by both active and passive sampling methods, in air, on surfaces, floor covering and feed samples, and analyzed through culture based-methods and qPCR. Smaller size range particles exhibited the highest counts, with indoor particles showing higher particle counts and mass concentration than outdoor particles. The limit values suggested for total bacteria load were surpassed in 35.7% (10 out of 28) of samples and for fungi in 65.5% (19 out of 29) of samples. Among Aspergillus genera, section Circumdati was the most prevalent (55%) on malt extract agar (MEA) and Versicolores the most identified (50%) on dichloran glycerol (DG18). The results document a wide characterization of occupational exposure to organic dust on swine farms, being useful for policies and stakeholders to act to improve workers’ safety. The methods of sampling and analysis employed were the most suitable considering the purpose of the study and should be adopted as a protocol to be followed in future exposure assessments in this occupational environment. PMID:29280976
Takaoka, Motoko; Suzuki, Kyoko; Norbäck, Dan
2017-08-01
To study associations between the school and home environment and current asthma, respiratory symptoms and airway infections among Japanese students. Japanese students (12-15 y) (N = 1048) in four schools responded to a questionnaire on respiratory health, allergy and the home environment. Temperature, relative air humidity (RH) and student density (students/m 2 floor area) was measured in the classrooms: dust was collected from floors and in classroom air and analysed for cat (Fel d 1) and dog (Can f 1) allergens. Health associations were analysed by multi-level logistic regression. Doctor's diagnosed asthma was common (13.4%), 8.8% reported cat allergy and 6.1% dog allergy. The median level in floor dust was 41 ng/g (IQR 23-92) for Fel d 1 and 101 ng/g (IQR 54-101) for Can f 1. The median level in air was 18.6 ng/ m 2 / day (IQR5.9-25.1) for Fel d 1 and 18.6 ng/ m 2 / day (IQR 6.0-13.3) for Can f 1. High RH, high student density and airborne cat allergen was associated with airway infections. In the home environment, recent indoor painting, new floor materials, odour, having cats as pets, window pane condensation in winter, and dampness in floor construction were associated with respiratory illness. High relative air humidity, high student density and airborne cat allergens at school may increase the risk of airway infections. Having cats as pets, chemical emissions from paint and new floor materials, odour and dampness can constitute domestic risk factors for respiratory symptoms while having dogs as pets could be protective.
Levallois, Patrick; St-Laurent, Julie; Gauvin, Denis; Courteau, Marilène; Prévost, Michèle; Campagna, Céline; Lemieux, France; Nour, Shokoufeh; D'Amour, Monique; Rasmussen, Pat E
2014-01-01
Lead is neurotoxic at very low dose and there is a need to better characterize the impact of domestic sources of lead on the biological exposure of young children. A cross-sectional survey evaluated the contribution of drinking water, house dust and paint to blood lead levels (BLLs) of young children living in old boroughs of Montréal (Canada). Three hundred and six children aged 1 to 5 years and currently drinking tap water participated in the study. For each participant, residential lead was measured in kitchen tap water, floor dust, windowsill dust and house paint and a venous blood sample was analyzed. Multivariate logistic regression was used to evaluate the association between elevated BLL in the children (≥ 75th percentile) and indoor lead contamination by means of odds ratios (OR) using 95% confidence intervals (CI). There was an association between BLL ≥75th percentile (1.78 μg/dL) and water lead when the mean water concentration was >3.3 μg/L: adjusted OR=4.7 (95% CI: 2.1–10.2). Windowsill dust loading >14.1 μg/ft2 was also associated with BLL ≥1.78 μg/dL: adjusted OR=3.2 (95% CI: 1.3–7.8). Despite relatively low BLLs, tap water and house dust lead contribute to an increase of BLLs in exposed young children. PMID:23361441
Park, J-H; Sulyok, M; Lemons, A R; Green, B J; Cox-Ganser, J M
2018-05-04
Recent developments in molecular and chemical methods have enabled the analysis of fungal DNA and secondary metabolites, often produced during fungal growth, in environmental samples. We compared 3 fungal analytical methods by analysing floor dust samples collected from an office building for fungi using viable culture, internal transcribed spacer (ITS) sequencing and secondary metabolites using liquid chromatography-tandem mass spectrometry. Of the 32 metabolites identified, 29 had a potential link to fungi with levels ranging from 0.04 (minimum for alternariol monomethylether) to 5700 ng/g (maximum for neoechinulin A). The number of fungal metabolites quantified per sample ranged from 8 to 16 (average = 13/sample). We identified 216 fungal operational taxonomic units (OTUs) with the number per sample ranging from 6 to 29 (average = 18/sample). We identified 37 fungal species using culture, and the number per sample ranged from 2 to 13 (average = 8/sample). Agreement in identification between ITS sequencing and culturing was weak (kappa = -0.12 to 0.27). The number of cultured fungal species poorly correlated with OTUs, which did not correlate with the number of metabolites. These suggest that using multiple measurement methods may provide an improved understanding of fungal exposures in indoor environments and that secondary metabolites may be considered as an additional source of exposure. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
2006-06-11
This MOC image shows a wide, flat-floored trough flanked by several smaller, branching troughs in the Olympica Fossae region of Mars. Dark- and intermediate-toned slope streaks -- created by dry avalanches of dust -- occur on the trough walls
PVC flooring is related to human uptake of phthalates in infants.
Carlstedt, F; Jönsson, B A G; Bornehag, C-G
2013-02-01
Polyvinyl chloride (PVC) flooring material contains phthalates, and it has been shown that such materials are important sources for phthalates in indoor dust. Phthalates are suspected endocrine-disrupting chemicals (EDCs). Consecutive infants between 2 and 6 months old and their mothers were invited. A questionnaire about indoor environmental factors and family lifestyle was used. Urinary metabolites of the phthalates diethyl phthalate (DEP), dibutyl phthalate (DBP), butylbenzyl phthalate (BBzP), and dietylhexyl phthalate (DEHP) were measured in the urine of the children. Of 209 invited children, 110 (52%) participated. Urine samples were obtained from 83 of these. Urine levels of the BBzP metabolite monobenzyl phthalate (MBzP) was significantly higher in infants with PVC flooring in their bedrooms (P < 0.007) and related to the body area of the infant. Levels of the DEHP metabolites MEHHP (P < 0.01) and MEOHP (P < 0.04) were higher in the 2-month-old infants who were not exclusively breast-fed when compared with breast-fed children. The findings indicate that the use of soft PVC as flooring material may increase the human uptake of phthalates in infants. Urinary levels of phthalate metabolites during early life are associated with the use of PVC flooring in the bedroom, body area, and the use of infant formula. This study shows that the uptake of phthalates is not only related to oral uptake from, for example, food but also to environmental factors such as building materials. This new information should be considered when designing indoor environment, especially for children. © 2012 John Wiley & Sons A/S.
Electrical Evolution of a Dust Plume from a Low Energy Lunar Impact: A Model Analog to LCROSS
NASA Technical Reports Server (NTRS)
Farrell, W. M.; Stubbs, T. J.; Jackson, T. L.; Colaprete, A.; Heldmann, J. L.; Schultz, P. H.; Killen, R. M.; Delory, G. T.; Halekas, J. S.; Marshall, J. R.;
2011-01-01
A Monte Carlo test particle model was developed that simulates the charge evolution of micron and sub-micron sized dust grains ejected upon low-energy impact of a moderate-size object onto a lunar polar crater floor. Our analog is the LCROSS impact into Cabeus crater. Our primary objective is to model grain discharging as the plume propagates upwards from shadowed crater into sunlight.
Binns, Helen J; Gray, Kimberly A; Chen, Tianyue; Finster, Mary E; Peneff, Nicholas; Schaefer, Peter; Ovsey, Victor; Fernandes, Joyce; Brown, Mavis; Dunlap, Barbara
2004-10-01
This study was designed primarily to evaluate the effectiveness of landscape coverings to reduce the potential for exposure to lead-contaminated soil in an urban neighborhood. Residential properties were randomized in to three groups: application of ground coverings/barriers plus placement of a raised garden bed (RB), application of ground coverings/barriers only (no raised bed, NRB), and control. Outcomes evaluated soil lead concentration (employing a weighting method to assess acute hazard soil lead [areas not fully covered] and potential hazard soil lead [all soil surfaces regardless of covering status]), density of landscape coverings (6 = heavy, > 90% covered; 1 = bare, < 10% covered), lead tracked onto carpeted entryway floor mats, and entryway floor dust lead loadings. Over 1 year, the intervention groups had significantly reduced acute hazard soil lead concentration (median change: RB, -478 ppm; NRB, -698 ppm; control, +52 ppm; Kruskal-Wallis, P = 0.02), enhanced landscape coverings (mean change in score: RB, +0.6; NRB, +1.5; control, -0.6; ANOVA, P < 0.001), and a 50% decrease in lead tracked onto the floor mats. The potential hazard soil lead concentration and the entryway floor dust lead loading did not change significantly. Techniques evaluated by this study are feasible for use by property owners but will require continued maintenance. The long-term sustainability of the method needs further examination.
NASA Technical Reports Server (NTRS)
2005-01-01
This movie clip shows a dust devil seen by NASA's Mars Exploration Rover Spirit during the rover's 532nd martian day, or sol (July 2, 2005). The dust-carrying whirlwind is moving across a plain inside Gusev Crater and viewed from Spirit's vantage point on hills rising from the plain. The clip consists of frames taken by Spirit's navigation camera, processed to enhance contrast for anything in the images that changes from frame to frame. The total elapsed time during the taking of these frames was 8 minutes, 48 seconds. Spirit began seeing dust devil activity around the beginning of Mars' spring season. Activity increased as spring continued, but fell off again for about two weeks during a dust storm. As the dust storm faded away, dust devil activity came back. In the mid-afternoons as the summer solstice approached, dust devils were a very common occurrence on the floor of Gusev crater. The early-spring dust devils tended to move southwest-to-northeast, across the dust devil streaks in Gusev seen from orbit. Increasingly as the season progresses, the dust devils are seen moving northwest-to-southeast, in the same direction as the streaks. Scientists are watching for the big dust devils that leave those streaks.Arbes, Samuel J.; Cohn, Richard D.; Yin, Ming; Muilenberg, Michael L.; Friedman, Warren; Zeldin, Darryl C.
2017-01-01
Background Exposures to dog and cat allergens are believed to play important roles in the etiology of asthma; however, the levels of these allergens have never been assessed in a representative sample of US homes. Objective The objective of this study was to estimate and characterize exposures to Can f 1 (dog allergen) and Fel d 1 (cat allergen) in US homes. Methods Data were obtained from the National Survey of Lead and Allergens in Housing, a nationally representative survey of 831 US homes. Vacuumed-collected dust samples from the bed, bedroom floor, living room floor, and living room sofa were analyzed for concentrations of Can f 1 and Fel d 1 (micrograms of allergen per gram of dust). Results Although a dog or cat had lived in only 49.1% of homes in the previous 6 months, Can f 1 and Fel d 1 were detected in 100% and 99.9% of homes, respectively. Averaged over the sampled sites, geometric mean concentrations (µg/g) were 4.69 for Can f 1 and 4.73 for Fel d 1. Among homes with an indoor dog and cat, respectively, geometric mean concentrations were 69 for Can f 1 and 200 for Fel d 1. Among homes without the indoor pet, geometric mean concentrations were above 1.0. The independent predictors of elevated concentrations in homes without pets were all demographic variables that were also linked to a higher prevalence of pet ownership. Conclusions Can f 1 and Fel d 1 are universally present in US homes. Levels that have been associated with an increased risk of allergic sensitization were found even in homes without pets. Because of the transportability of these allergens on clothing, elevated levels in homes without pets, particularly among demographic groups in which pet ownership is more prevalent, implicate the community as an important source of these pet allergens. PMID:19055206
Wickens, K; Mason, K; Fitzharris, P; Siebers, R; Hearfield, M; Cunningham, M; Crane, J
2001-06-01
A previous study of homes in Wellington, New Zealand showed that having carpets on floors was the most important determinant of floor Der p 1 levels, but there was much unexplained variability between houses in carpet levels. To determine to what extent housing characteristics might explain this variability in Der p 1 levels between houses. We returned to a selection of houses with carpets and sampled living room dust from 1 square metre for 1 min and from the whole floor at 5 m(2) per min. Der p 1 levels were estimated by double monoclonal antibody ELISA and are expressed as geometric mean microg/g and microg/m(2) (95% confidence intervals). Questionnaires were used to collect information on housing characteristics. Der p 1 levels were significantly higher in the 1 square metre sample (40.0, 31.9-50.2 microg/g; 53.4, 41.4-68.9 microg/m(2)) than in the whole room (25.8, 21.3-31.1 microg/g; 5.3, 3.8-7.4 microg/m(2)). However, results from the different sampling methods were correlated (r = 0.51, P = 0.001 for microg/g and r = 0.58, P = 0.001 for microg/m(2)). After controlling for possible confounders, houses with insulation or a room or garage below the living room had approximately half the Der p 1 concentration (P = 0.05 for both samples) and the amount of Der p 1 per m(2) (P = 0.004 for the 1 square meter sample, P = 0.06 for the whole room sample) than houses without these features. Having more than two children was associated with higher levels of Der p 1 in 1 square meter, significant (P = 0.05) for microg/m(2). Carpet underlay less than 8 mm thick was associated with an almost 3-fold increase in microg/m(2) Der p 1 (P = 0.03) and a 1.6-fold increase in microg/g Der p 1 (P = 0.08) in the whole room sample, when compared with thicker carpet underlays. The presence of insulation is the single most important housing characteristic explaining the between-house variability in Der p 1 levels on carpeted living room floors.
Tsurikisawa, Naomi; Saito, Akemi; Oshikata, Chiyako; Yasueda, Hiroshi; Akiyama, Kazuo
2016-10-01
We investigated the best strategy for adult asthmatics to avoid exposure to Dermatophagoides group (Der-1) allergens. Adult atopic asthmatics (n = 111) followed a 32-item checklist for avoiding Der-1 allergen exposure. Twenty-five patients were excluded through incomplete sampling; 50 remaining patients encased their pillows/futons/mattresses in microfine-fiber covers, 13 used vacuum cleaners with dust-mite-collection nozzles, and 23 acted as non-intervention controls. During August-October 2010 and August-October 2011, dust samples were collected in Petri dishes placed in bedrooms for 2 weeks and from mattresses/futons by using adhesive tape on one morning. A Der-1 level decrease was defined as a mean 2011 Der-1 level of <1 as a ratio of the 2010 level on tape or Petri dish samples. We analyzed the associations between Der-1 level change (by ELISA) and % weekly variability in peak expiratory flow (PEF) or fraction of exhaled nitric oxide (FeNO) after intervention. Der-1 levels decreased significantly in the covers group but not the vacuuming group. FeNO levels and PEF variability were unchanged in both groups. In patients whose Petri dish or tape samples showed decreased Der-1 levels, the % PEF variability was lower in 2011 than in 2010, but FeNO levels were unchanged. Three interventions (vacuuming all family members' mattress/futon surfaces at least weekly or after exposure of the futons to sunlight, and floor wiping before vacuuming), plus using covers, were the most effective management strategy in reducing Der-1 levels. This environmental and bedding maintenance program may help manage adult atopic asthma.
Identification of potential hazards associated with new residential construction.
Methner, M M
2000-02-01
There were several advantages and limitations of this observational study. The most important advantage of this study was the opportunity to observe residential construction workers performing their jobs. By observing work practices, valuable information was gathered about specific trades and their potential exposure to various chemical and physical agents. This information will be useful in guiding subsequent exposure assessments. Probably the greatest limitation of this study was the lack of participation by homebuilders. Ideally, observations of construction processes would have been more objective if the study included the participation of more than one homebuilder. Aside from one worker who was observed to wear safety glasses, leather gloves, and a dust mask, virtually no personal protective equipment (PPE) was observed onsite. Often small contractors do not have the financial resources necessary to procure the appropriate PPE and issue these items to the workers. Based on hazard prevalence, professional judgement, and the degree of hazardous product use, potential exposures that warrant quantitative sampling efforts during Phase 2 of this study are: bulldozer/backhoe operators--noise, vibration, diesel exhaust; concrete workers--naphtha, mineral spirits, Portland cement; asphalt workers--petroleum hydrocarbons, asphalt, mineral spirits; plumbers--methylethyl ketone, acetone, tetrahydrofuran, cyclohexanone; drywall finishers--total and respirable dust, hexane, acetone; painters--ethylene glycol, VOCs; masons--dust (during the preparation of mortar); floor preparation technicians--total and respirable dust; and ceramic tile installers--toluene, naphtha, silica (from grout powder).
Sol 568 Dust Devil in Gusev, Unenhanced
NASA Technical Reports Server (NTRS)
2005-01-01
This movie clip shows several dust devils moving from right to left across a plain inside Mars' Gusev Crater, as seen from the vantage point of NASA's Mars Exploration Rover Spirit in hills rising from the plain. The clip consists of frames taken by Spirit's navigation camera during the rover's 543rd martian day, or sol (July 13, 2005). Unlike some other movie clips of dust devils seen by Spirit, the images in this clip have not been processed to enhance contrast of the dust devils. The total time elapsed during the taking of these frames was 12 minutes, 17 seconds. Spirit began seeing dust devil activity around the beginning of Mars' spring season. Activity increased as spring continued, but fell off again for about two weeks during a dust storm. As the dust storm faded away, dust devil activity came back. In the mid-afternoons as the summer solstice approached, dust devils were a very common occurrence on the floor of Gusev crater. The early-spring dust devils tended to move southwest-to-northeast, across the dust devil streaks in Gusev seen from orbit. Increasingly as the season progresses, the dust devils are seen moving northwest-to-southeast, in the same direction as the streaks. Scientists are watching for the big dust devils that leave those streaks.Chulada, Patricia C.; Kennedy, Suzanne; White, LuAnn; Wildfire, Jeremy; Cohn, Richard D.; Mitchell, Herman; Thornton, Eleanor; El-Dahr, Jane; Mvula, Mosanda M.; Sterling, Yvonne; Martin, William J.; Stephens, Kevin U.; Lichtveld, Maureen
2012-01-01
Background: Rain and flooding from Hurricane Katrina resulted in widespread growth of mold and bacteria and production of allergens in New Orleans, Louisiana, which may have led to increased exposures and morbidity in children with asthma. Objectives: The goal of the Head-off Environmental Asthma in Louisiana (HEAL) study was to characterize post-Katrina exposures to mold and allergens in children with asthma. Methods: The homes of 182 children with asthma in New Orleans and surrounding parishes were evaluated by visual inspection, temperature and moisture measurements, and air and dust sampling. Air was collected using vacuum-pump spore traps and analyzed for > 30 mold taxa using bright field microscopy. Dust was collected from the children’s beds and bedroom floors and analyzed for mouse (Mus m 1), dust mite (Der p 1), cockroach (Bla g 1), and mold (Alternaria mix) allergens using ELISA. Results: More than half (62%) of the children were living in homes that had been damaged by rain, flooding, or both. Geometric mean indoor and outdoor airborne mold levels were 501 and 3,958 spores/m3, respectively. Alternaria antigen was detected in dust from 98% of homes, with 58% having concentrations > 10 µg/g. Mus m 1, Der p 1, and Bla g 1 were detected in 60%, 35%, and 20% of homes, respectively, at low mean concentrations. Conclusions: Except for Alternaria antigen in dust, concentrations of airborne mold (ratio of indoor to outdoor mold) and dust allergens in the homes of HEAL children were lower than measurements found in other studies, possibly because of extensive post-Katrina mold remediation and renovations, or because children moved into cleaner homes upon returning to New Orleans. PMID:22894816
Grimsley, L Faye; Chulada, Patricia C; Kennedy, Suzanne; White, LuAnn; Wildfire, Jeremy; Cohn, Richard D; Mitchell, Herman; Thornton, Eleanor; El-Dahr, Jane; Mvula, Mosanda M; Sterling, Yvonne; Martin, William J; Stephens, Kevin U; Lichtveld, Maureen
2012-11-01
Rain and flooding from Hurricane Katrina resulted in widespread growth of mold and bacteria and production of allergens in New Orleans, Louisiana, which may have led to increased exposures and morbidity in children with asthma. The goal of the Head-off Environmental Asthma in Louisiana (HEAL) study was to characterize post-Katrina exposures to mold and allergens in children with asthma. The homes of 182 children with asthma in New Orleans and surrounding parishes were evaluated by visual inspection, temperature and moisture measurements, and air and dust sampling. Air was collected using vacuum-pump spore traps and analyzed for > 30 mold taxa using bright field microscopy. Dust was collected from the children's beds and bedroom floors and analyzed for mouse (Mus m 1), dust mite (Der p 1), cockroach (Bla g 1), and mold (Alternaria mix) allergens using ELISA. More than half (62%) of the children were living in homes that had been damaged by rain, flooding, or both. Geometric mean indoor and outdoor airborne mold levels were 501 and 3,958 spores/m3, respectively. Alternaria antigen was detected in dust from 98% of homes, with 58% having concentrations > 10 µg/g. Mus m 1, Der p 1, and Bla g 1 were detected in 60%, 35%, and 20% of homes, respectively, at low mean concentrations. Except for Alternaria antigen in dust, concentrations of airborne mold (ratio of indoor to outdoor mold) and dust allergens in the homes of HEAL children were lower than measurements found in other studies, possibly because of extensive post-Katrina mold remediation and renovations, or because children moved into cleaner homes upon returning to New Orleans.
Xu, Ying; Hubal, Elaine A Cohen; Clausen, Per A; Little, John C
2009-04-01
A two-room model is developed to estimate the emission rate of di-2-ethylhexyl phthalate (DEHP) from vinyl flooring and the evolving gas-phase and adsorbed surface concentrations in a realistic indoor environment. Because the DEHP emission rate measured in a test chamber may be quite different from the emission rate from the same material in the indoor environment the model provides a convenient means to predict emissions and transport in a more realistic setting. Adsorption isotherms for phthalates and plasticizers on interior surfaces, such as carpet, wood, dust, and human skin, are derived from previous field and laboratory studies. Log-linear relationships between equilibrium parameters and chemical vapor pressure are obtained. The predicted indoor air DEHP concentration at steady state is 0.15 microg/m3. Room 1 reaches steady state within about one year, while the adjacent room reaches steady state about three months later. Ventilation rate has a strong influence on DEHP emission rate while total suspended particle concentration has a substantial impact on gas-phase concentration. Exposure to DEHP via inhalation, dermal absorption, and oral ingestion of dust is evaluated. The model clarifies the mechanisms that govern the release of DEHP from vinyl flooring and the subsequent interactions with interior surfaces, airborne particles, dust, and human skin. Although further model development, parameter identification, and model validation are needed, our preliminary model provides a mechanistic framework that elucidates exposure pathways for phthalate plasticizers, and can most likely be adapted to predict emissions and transport of other semivolatile organic compounds, such as brominated flame retardants and biocides, in a residential environment.
2010-11-15
This image from NASA Mars Reconnaissance Orbiter shows the funnel-shaped terminus of Lethe Vallis, a winding channel in the Elysium Planitia region of Mars; the floor is covered in solidified lava and blanketed by a thin layer of light-toned dust.
House dust in seven Danish offices
NASA Astrophysics Data System (ADS)
Mølhave, L.; Schneider, T.; Kjærgaard, S. K.; Larsen, L.; Norn, S.; Jørgensen, O.
Floor dust from Danish offices was collected and analyzed. The dust was to be used in an exposure experiment. The dust was analyzed to show the composition of the dust which can be a source of airborne dust indoors. About 11 kg of dust from vacuum cleaner bags from seven Danish office buildings with about 1047 occupants (12 751 m 2) was processed according to a standardized procedure yielding 5.5 kg of processed bulk dust. The bulk dust contained 130.000-160.000 CFU g -1 microorganisms and 71.000-90.000 CFU g -1 microfungi. The content of culturable microfungi was 65-123 CFU 30 g -1 dust. The content of endotoxins ranged from 5.06-7.24 EU g -1 (1.45 ng g -1 to 1.01 ng g -1). Allergens (ng g -1) were from 147-159 (Mite), 395-746 (dog) and 103-330 (cat). The macro molecular organic compounds (the MOD-content) varied from 7.8-9.8 mg g -1. The threshold of release of histamine from basophil leukocytes provoked by the bulk dust was between 0.3 and 1.0 mg ml -1. The water content was 2% (WGT) and the organic fraction 33%. 6.5-5.9% (dry) was water soluble. The fiber content was less than 0.2-1.5% (WGT) and the desorbable VOCs was 176-319 μg g -1. Most of the VOC were aldehydes. However, softeners for plastic (DBP and DEHP) were present. The chemical composition includes human and animal skin fragments, paper fibers, glass wool, wood and textilefibers and inorganic and metal particles. The sizes ranged from 0.001-1 mm and the average specific density was 1.0 g m -3. The bulk dust was resuspended and injected into an exposure chamber. The airborne dust was sampled and analyzed to illustrate the exposures that can result from sedimented dirt and dust. The airborne dust resulting from the bulk dust reached concentrations ranging from 0.26-0.75 mg m -3 in average contained 300-170 CFU m -3. The organic fraction was from 55-70% and the water content about 2.5% (WGT). The content of the dust was compared to the similar results reported in the literature and its toxic potency is estimated to be relatively low. The storage of the bulk dust during the experiment had little effect on the specific biological and chemical composition.
Ventilation in homes infested by house-dust mites.
Sundell, J; Wickman, M; Pershagen, G; Nordvall, S L
1995-02-01
Thirty single-family homes with either high (> or = 2000 ng/g) or low (< or = 1000 ng/g) house-dust mite (HDM) allergen levels in mattress dust were examined for ventilation, thermal climate, and air quality (formaldehyde and total volatile organic compounds (TVOC). Elevated concentrations of HDM allergen in mattress and floor dust were associated with the difference in absolute humidity between indoor and outdoor air, as well as with low air-change rates of the home, particularly the bedroom. No correlation was found between concentration of TVOC or formaldehyde in bedroom air and HDM allergen concentration. In regions with a cold winter climate, the air-change rate of the home and the infiltration of outdoor air into the bedroom appear to be important for the infestation of HDM.
2006-06-01
This MOC image shows windblown ripples on the floor of Auqakuh Vallis. The light-toned area, running diagonally across the scene from the lower left to the upper right, may be dust that has accumulated in the bottom of the valley and on top of the ripples
Muenhor, Dudsadee; Harrad, Stuart; Ali, Nadeem; Covaci, Adrian
2010-10-01
This study reports concentrations of brominated flame retardants in dust samples (n=25) and in indoor (n=5) and outdoor air (n=10) (using PUF disk passive air samplers) from 5 electronic and electrical waste (e-waste) storage facilities in Thailand. Concentrations of Sigma(10)PBDEs (BDEs 17, 28, 47, 49, 66, 85, 99, 100, 153 and 154) in outdoor air in the vicinity of e-waste storage facilities ranged from 8 to 150 pg m(-3). Indoor air concentrations ranged from 46 to 350 pg m(-3), with highest concentrations found in a personal computer and printer waste storage room at an e-waste storage facility. These are lower than reported previously for electronic waste treatment facilities in China, Sweden, and the US. Concentrations of Sigma(21)PBDEs (Sigma(10)PBDEs+BDEs 181, 183, 184, 191, 196, 197, 203, 206, 207, 208 and 209), decabromodiphenylethane (DBDPE), decabromobiphenyl (BB-209) in dust were 320-290,000, 43-8700 and <20-2300 ng g(-1) respectively, with the highest concentrations of Sigma(21)PBDEs, BDE-209 and DBDPE in a room used to house discarded TVs, stereos and radios. PBDE concentrations in dust were slightly higher but within the range of those detected in workshop floor dust from an e-waste recycling centre in China. The highest concentration of BB-209 was detected in a room storing discarded personal computers and printers. Consistent with recent reports of elevated ratios of BDE-208:BDE-209 and BDE-183:BDE-209 in household electronics from South China, percentage ratios of BDE-208:BDE-209 (0.64-2.9%) and of BDE-208:BDE-183 (2.8-933%) in dust samples exceeded substantially those present in commercial deca-BDE and octa-BDE formulations. This suggests direct migration of BDE-208 and other nonabrominated BDEs from e-waste to the environment. Under realistic high-end scenarios of occupational exposure to BDE-99, workers in the facilities were exposed above a recently-published Health Based Limit Value for this congener. Reassuringly, estimated exposures to BDE-209 were below the USEPA's reference dose for this congener. Copyright 2010 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Cambra-López, María; Winkel, Albert; Mosquera, Julio; Ogink, Nico W. M.; Aarnink, André J. A.
2015-06-01
The objective of this study was to compare co-located real-time light scattering devices and equivalent gravimetric samplers in poultry and pig houses for PM10 mass concentration, and to develop animal-specific calibration factors for light scattering samplers. These results will contribute to evaluate the comparability of different sampling instruments for PM10 concentrations. Paired DustTrak light scattering device (DustTrak aerosol monitor, TSI, U.S.) and PM10 gravimetric cyclone sampler were used for measuring PM10 mass concentrations during 24 h periods (from noon to noon) inside animal houses. Sampling was conducted in 32 animal houses in the Netherlands, including broilers, broiler breeders, layers in floor and in aviary system, turkeys, piglets, growing-finishing pigs in traditional and low emission housing with dry and liquid feed, and sows in individual and group housing. A total of 119 pairs of 24 h measurements (55 for poultry and 64 for pigs) were recorded and analyzed using linear regression analysis. Deviations between samplers were calculated and discussed. In poultry, cyclone sampler and DustTrak data fitted well to a linear regression, with a regression coefficient equal to 0.41, an intercept of 0.16 mg m-3 and a correlation coefficient of 0.91 (excluding turkeys). Results in turkeys showed a regression coefficient equal to 1.1 (P = 0.49), an intercept of 0.06 mg m-3 (P < 0.0001) and a correlation coefficient of 0.98. In pigs, we found a regression coefficient equal to 0.61, an intercept of 0.05 mg m-3 and a correlation coefficient of 0.84. Measured PM10 concentrations using DustTraks were clearly underestimated (approx. by a factor 2) in both poultry and pig housing systems compared with cyclone pre-separators. Absolute, relative, and random deviations increased with concentration. DustTrak light scattering devices should be self-calibrated to investigate PM10 mass concentrations accurately in animal houses. We recommend linear regression equations as animal-specific calibration factors for DustTraks instead of manufacturer calibration factors, especially in heavily dusty environments such as animal houses.
PBDEs emission from waste printed wiring boards during thermal process.
Guo, Jie; Zhang, Ran; Xu, Zhenming
2015-03-03
Polybrominated diphenyl ethers (PBDEs) contained in waste printed wiring board (PWB) matrix and surface dust can be emitted into the air during thermal process, which is widely used to detach the electronic components from the base boards of waste PWB. In this study, PBDEs concentrations in air and dust samples were detected in a PWB-heating workshop, and then heating experiments of PBDEs-containing materials in a quartz tube furnace were performed to investigate the PBDEs emission mechanism. The results showed that the mean concentrations of Σ8PBDEs in PM10 and TSP were 479 and 1670 ng/m(3), respectively. Compared with surface dust collected from waste PWB (15600 ng/g), PBDEs concentrations in dust from the workshop floor (31,100 ng/g), heating machine inside (84,700 ng/g), and the cyclone extractor (317,000 ng/g), were condensed after thermal process. Heating experiments showed that the emission rates of PBDEs from PBDEs-containing dust were obviously higher than those from PWB fragments in the first 1-h time. The cumulative amounts of PBDEs emitted from dust increased rapidly at first, and then leveled off to become asymptotic to the maximum amounts. At the temperature of 300 °C, the PBDEs emission from dust mainly occurred within the first 5 min, and the average emission rates for BDE-28, -47, and -99 among the first 5 min were 1230, 4480, and 1950 ng/(g·min), respectively. During the initial 1-h period, the trends of PBDEs emission from PWB fragments had a linear increase, and the emission rates of penta-BDE (BDE-47, -99, -100) at different temperatures were at a range of 9.75-11.5 ng/(g·min). All the results showed that PBDEs emission from PWB waste happened during thermal process, and management strategies were provided to reduce the occupational exposure level of PBDEs for workers.
NASA Technical Reports Server (NTRS)
Gaier, James R.; deLeon, Pablo G.; Lee, Pascal; McCue, Terry R.; Hodgson, Edward W.; Thrasher, Jeff
2010-01-01
In August 2009 YAP Films (Toronto) received permission from all entities involved to create a documentary film illustrating what it might be like to be on the surface of Mars in a space suit during a dust storm or in a dust devil. The science consultants on this project utilized this opportunity to collect data which could be helpful to assess the durability of current space suit construction to the Martian environment. The NDX?1 prototype planetary space suit developed at the University of North Dakota was used in this study. The suit features a hard upper torso garment, and a soft lower torso and boots assembly. On top of that, a nylon-cotton outer layer is used to protect the suit from dust. Unmanned tests were carried out in the Martian Surface Wind Tunnel (MARSWIT) at the NASA Ames Research Center, with the suit pressurized to 10 kPa gauge. These tests blasted the space suit upper torso and helmet, and a collection of nine candidate outer layer fabrics, with wind-borne simulant for five different 10 minute tests under both terrestrial and Martian surface pressures. The infiltration of the dust through the outer fabric of the space suit was photographically documented. The nine fabric samples were analyzed under light and electron microscopes for abrasion damage. Manned tests were carried out at Showbiz Studios (Van Nuys, CA) with the pressure maintained at 20?2 kPa gauge. A large fan-created vortex lifted Martian dust simulant (Fullers Earth or JSC Mars?1) off of the floor, and one of the authors (Lee) wearing the NDX?1 space suit walked through it to judge both subjectively and objectively how the suit performed under these conditions. Both the procedures to scale the tests to Martian conditions and the results of the infiltration and abrasion studies will be discussed.
NASA Technical Reports Server (NTRS)
Gaier, James R.; deLeon, Pablo G.; Lee, Pascal; McCue, Terry R.; Hodgson, Edward W.; Thrasher, Jeff
2010-01-01
In August 2009 YAP Films (Toronto) received permission from all entities involved to create a documentary film illustrating what it might be like to be on the surface of Mars in a space suit during a dust storm or in a dust devil. The science consultants on this project utilized this opportunity to collect data which could be helpful to assess the durability of current space suit construction to the Martian environment. The NDX-1 prototype planetary space suit developed at the University of North Dakota was used in this study. The suit features a hard upper torso garment, and a soft lower torso and boots assembly. On top of that, a nylon-cotton outer layer is used to protect the suit from dust. Unmanned tests were carried out in the Martian Surface Wind Tunnel (MARSWIT) at the NASA Ames Research Center, with the suit pressurized to 10 kPa gauge. These tests blasted the space suit upper torso and helmet, and a collection of nine candidate outer layer fabrics, with wind-borne simulant for five different 10 min tests under both terrestrial and Martian surface pressures. The infiltration of the dust through the outer fabric of the space suit was photographically documented. The nine fabric samples were analyzed under light and electron microscopes for abrasion damage. Manned tests were carried out at Showbiz Studios (Van Nuys, California) with the pressure maintained at 20 2 kPa gauge. A large fan-created vortex lifted Martian dust simulant (Fullers Earth or JSC Mars-1) off of the floor, and one of the authors (Lee) wearing the NDX-1 space suit walked through it to judge both subjectively and objectively how the suit performed under these conditions. Both the procedures to scale the tests to Martian conditions and the results of the infiltration and abrasion studies will be discussed.
Environmental and dietary exposure of young children to inorganic trace elements.
Glorennec, Philippe; Lucas, Jean-Paul; Mercat, Anne-Camille; Roudot, Alain-Claude; Le Bot, Barbara
2016-12-01
Children are exposed to toxic metals and metalloids via their diet and environment. Our objective was to assess the aggregate chronic exposure of children aged 3-6years, living in France, to As, Cd, Cr, Cu, Mn, Pb, Sb, Sr, and V present in diet, tap water, air, soil and floor dust in the years 2007-2009. Dietary data came from the French Total Diet Study, while concentrations in residential tap water, soil and indoor floor dust came from the 'Plomb-Habitat' nationwide representative survey on children's lead exposure at home. Indoor air concentrations were assumed to be equal to outdoor air concentrations, which were retrieved from regulatory measurements networks. Human exposure factors were retrieved from literature. Data were combined with Monte Carlo simulations. Median exposures were 1.7, 0.3, 10.2, 34.1, 60.3, 0.7, 0.1, 44.3, 1.5 and 95th percentiles were 4.4, 0.5, 15.8, 61.3, 98.3, 2.5, 0.1, 111.1, 2.9μg/kgbw/d for As, Cd, Cr, Cu, Mn, Pb, Sb, Sr, and V respectively. Dietary exposures dominate aggregate exposures, with the notable exception of Pb - for which soils and indoor floor dust ingestion contribute most at the 95th percentile. The strengths of this study are that it aggregates exposures that are often estimated separately, and uses a large amount of representative data. This assessment is limited to main diet and residential exposure, and does not take into account the relative bioavailability of compounds. These results could be used to help target prevention strategies. Copyright © 2016 Elsevier Ltd. All rights reserved.
Hyperspectral characterisation of the Martian south polar residual cap using CRISM
NASA Astrophysics Data System (ADS)
Campbell, J. D.; Sidiropoulos, P.; Muller, J.-P.
2017-09-01
We present our research on hyperspectral characterization of the Martian South Polar Residual Cap (SPRC), with a focus on the detection of organic signatures within the dust content of the ice. The SPRC exhibits unique CO2 ice sublimation features known colloquially as 'Swiss Cheese Terrain' (SCT). These flat floored, circular depressions are highly dynamic, and may expose dust particles previously trapped within the ice in the depression walls and partially on the floors. Here we identify suitable regions for potential dust exposure on the SPRC, and utilise data from the Compact Reconnaissance Imaging Spectrometer for Mars (CRISM) on board NASA's Mars Reconnaissance Orbiter (MRO) satellite to examine infrared spectra of dark regions to establish their mineral composition, to eliminate the effects of ices on sub-pixel dusty features, and to assess whether ther might be signatures indicative of Polycyclic Aromatic Hydrocarbons (PAHs). Spectral mapping has identified compositional differences between depression rims and the majority of the SPRC and CRISM spectra have been corrected to minimise the influence of CO2 and H2O ice. Whilst no conclusive evidence for PAHs has been found, depression rims are shown to have higher water content than regions of featureless ice, and there are indications of magnesium carbonate within the dark, dusty regions.
Hypersensitivity pneumonitis in a hardwood processing plant related to heavy mold exposure.
Veillette, Marc; Cormier, Yvon; Israël-Assayaq, Evelyne; Meriaux, Anne; Duchaine, Caroline
2006-06-01
Two workers employed in a hardwood floor plant presented symptoms suggestive of hypersensitivity pneumonitis (HP). At that plant, kiln-dried wood often shows moldy growth and is subsequently brought inside for processing. This study evaluated the environment in attempt to identify the causative antigen and verify whether other workers of this and similar plants had or were at risk of developing HP. Dust from dust-removing systems and molds on the surface of wood planks were collected and air samples taken from a sister plant. Blood samples, spirometry, and symptoms' questionnaires were obtained from 11 co-workers. Dense Paecilomyces growth was observed on the surface of the dried processed wood in the index plant. This fungal genus was not detected in the sister plant. An additional worker had symptoms suggestive of HP, and his bronchoalveolar lavage revealed a lymphocytic alveolitis. The 3 confirmed cases of HP and the other 10 workers had positive specific IgG antibodies to Paecilomyces. We report 3 cases of HP out of 13 workers and a 100% sensitization to molds in workers of a hardwood processing plant. This rate is much higher than what is commonly seen in other environments associated with HP. The drying process is suspected of being responsible for the massive Paecilomyces contamination likely responsible for the HP.
Determinants of endotoxin levels in carpets in New Zealand homes.
Wickens, K; Douwes, J; Siebers, R; Fitzharris, P; Wouters, I; Doekes, G; Mason, K; Hearfield, M; Cunningham, M; Crane, J
2003-06-01
Endotoxin in house dust has been shown to be associated with asthma severity. Little is known about the influence of housing characteristics on endotoxin distribution. Using standardized methods, dust was sampled from a 1m(2) site and the whole accessible carpet area in selected Wellington, New Zealand homes (n = 77). Endotoxin was measured using a Limulus Amoebocyte Lysate assay. Relative humidity and temperature were recorded using sensors placed in carpet bases. Questionnaires were used to collect information on housing characteristics. All analyses were performed for endotoxin units (EU)/mg and EU/m2 for each site. Geometric mean endotoxin levels were 22.7 EU/mg [geometric standard deviation (GSD) = 2.4] or 30,544 EU/m2 (GSD = 3.2) from the 1m(2) site, and 28.4 EU/mg (GSD = 3.4) or 5653 EU/m2 (GSD = 6.4) from the whole room. After controlling for confounding, endotoxin was positively associated with dogs inside [geometric mean ratio (GMR): 0.9-2.0], total household occupants (GMR: 1.7-2.0, for 1 m2 sample only), vacuum cleaners <1-year old (GMR: 2.3-2.7), reusing vacuum dust collection bags (GMR: 1.4-3.1), steamcleaning or shampooing the carpet (GMR: 1.4-2.2) and high relative humidity (GMR: 1.4-1.6). Lower endotoxin was associated with floor insulation (GMR: 0.4-0.8), and north-facing living rooms (GMR: 0.4-0.8). This study has identified home characteristics that could be modified to reduce endotoxin exposure.
NASA Astrophysics Data System (ADS)
Pingitore, N. E.; Clague, J.; Amaya, M. A.
2006-12-01
Understanding the interplay of indoor and outdoor sources of lead in an urban setting is one foundation in establishing risk for lead exposure in children in our cities. A household may be the source for lead contamination due to the deterioration of interior lead-based paint, or a sink if lead particles are tracked or blown into the home from such potential ambient sources as yard soil or urban street dust. In addressing this issue, X-Ray Absorption Spectroscopy (XAS) presents the opportunity to directly and quantitatively speciate lead at low concentrations in bulk samples. We performed XAS analyses on dust wipes from window sills or floors from 8 houses that exceeded Federal standards for lead in dust. We entered these data into a Principal Components Analysis (PCA) that also included El Paso environmental samples: lead-based paints, soils, and airborne particulate matter. A simple two-component mixing system accounted for more than 95% of the variance of this data set. Paint and lead oxide appear to be the principal components, with all the samples falling in a compositional range from pure paint to 75% paint, 25% lead oxide. Note that several different lead compounds are possible constituents of a given lead-based paint. The paints spread from one end out along perhaps a fifth of the range of the compositional axis, followed closely, but not overlapped, by the soil samples, which covered the remainder of the compositional range. Two of the dust wipes plotted within the paint range, and the remaining 6 dust wipes plotted randomly through the soil range. Samples of airborne particulate matter plotted in both the paint and soil ranges. These observations suggest that the lead on most of the dust wipes originated outside the house, probably from deteriorated exterior lead-based paint deposited in adjacent yards. This paint mixed with lead oxide present in the soil and entered the houses by the airborne route. The probable source of the oxide in the soil is former airborne deposition of automobile exhaust from leaded gasoline (lead halides quickly react to form oxide). The dust wipes that fall within the compositional range of the paints may have originated from deterioration of interior paint. The XAS findings are consistent with our tests of several hundred houses in El Paso: most of the wipes that exceeded Federal lead standards came from houses in the oldest neighborhoods of the city, where lead paint is still present. X-Ray absorption spectroscopy experiments were conducted at the Stanford Synchrotron Radiation Laboratory on beam lines 7-3 and 10-2. Spectra were collected at the Pb L-III absorption edge in fluorescence mode using a 13-element or a 30-element Ge solid-state detector. This publication was made possible by grant numbers 1RO1-ES11367 and 1 S11 ES013339-01A1 from the National Institute of Environmental Health Sciences (NIEHS), NIH. Its contents are solely the responsibility of the authors and do not necessarily represent the official views of the NIEHS, NIH.
Malysheva, A G; Abramov, E G
2006-01-01
The high concentrations of lead were reveled in the air and dust of some premises and on the filters of a combined air-conditioning extract-and-input system in the high-rise office buildings located in the ecologically lead favorable environment. The dust content of lead in some premises on the first floors dust was as high as 200 mg/kg, which was more than 6 times higher than that in the soil at the highway near the office buildings. The use of new technologies and devices for cleaning and optimizing the air in the premises requires analytical studies to assess the quality of the environment, by taking into account the optimal conditions of their operation.
Thermal and visible studies of Mars using the Termoskan data set
NASA Astrophysics Data System (ADS)
Betts, Bruce Harold
1994-01-01
In 1989, the Soviet Phobos '88 Termoskan instrument acquired the highest spatial resolution thermal data ever for Mars, (300 m to 3 km per pixel), and simultaneous broad band visible data. The panoramas cover a large portion of the equatorial region from 30 deg S to 6 deg N. This thesis presents new and unique analyses facilitated by Termoskan and describes the instrument, data, and validation. Ejecta blankets distinct in the thermal infrared (EDITHs), a newly recognized type of feature, show a strong dependence upon Hesperian aged terrains. I postulate that most of the observed EDITHs are due to excavation of thermally distinctive Noachian age material from beneath a relatively thin layer of younger, more consolidated Hesperian volcanic material. EDITHs are excellent targets for future landers and orbiters because of relatively dust free surface exposures of material excavated from depth. Most observed channels have higher inertias than their surroundings. Channel inertia lower bounds range from 8.4 to 12.5 (10-3 cal/sq cm s-1/2/K. Channel floor inertia enhancements are strongly associated with channels showing fretted morphologies such as wide, flat floors. Fretting may have emplaced more blocks on channel floors or caused increased bonding of fines due to increased availability of water. The coupling to morphology of EDITH and channel inertias is unlike most Martian inertia variations. Termoskan observed fine thermal structure at the limit of its spatial resolution, implying there cannot be global scale dust blanketing deeper than about one centimeter. Morning limb brightening in the thermal channel is likely due to a water ice or dust hare that is warmer than the surface at the time of the observations. In the visible channel, scattering is significant to 70 km and localized high altitude stratospheric clouds are observed. Termoskan obtained the first ever thermal images of Phobos' shadow on the surface of Mars. I used the observed cooling to calculate thermal inertias in the upper mm of the Martian surface. Most of the derived inertias on the flanks of Arsia Mons fall within the range 0.9 to 1.4, corresponding to 5 to 10 micron dust particles for a homogeneous surface.
Mite fauna and fungal flora in house dust from homes of asthmatic children.
Ishii, A; Takaoka, M; Ichinoe, M; Kabasawa, Y; Ouchi, T
1979-12-01
Mite fauna and fungal flora in the house dust from homes of asthmatic children with positive and negative skin test to house dust allergen and non-asthmatic controls were examined. There was no conspicuous difference in mite species distribution among the three groups. Pyroglyphid mites dominate the mite fauna in house dust more than half of which being Dermatophagoides: D. pteronyssinus and D. farinae. There was no statistically significant difference in numbers between the two species and either species could dominate depending on the conditions of the individual houses. The average number of acarina in 0.5 g of fine dust did not differ statistically among the three groups; however, mite number per square meter floor differed between patients with positive skin test and negative skin test. The results suggest that house-cleaning might influence the possible sensitization of children. The genetic distribution of mould fungi in house dust was largely similar to that of airborne fungi. The average number of fungal colonies detected in 0.5 g of dust did not differ statistically among the three groups. Wallemia with its minute spores may cause sensitization but has so far been insufficiently investigated.
Control technology for Richard Klinger, Inc. , Sidney, Ohio. Indepth survey report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heitbrink, W.A.
1984-06-25
Environmental and breathing zone samples were analyzed for asbestos (1332214) at Richard Klinger Incorporated (SIC-3069), Sidney, Ohio in August 1983 as part of an in depth study of dust control during bag opening, dumping, and disposal. Asbestos control technology was inspected. Control of asbestos at the facility was achieved by using an automatic cleaner to clean spills and routinely remove settled and spilled asbestos from the floor. During periods of peak exposure, workers wore NIOSH approved respirators and disposable coveralls. Air sampling was used to identify any asbestos control problems. Closed bales of asbestos were torn. The author concludes thatmore » operation of the bag slitter does not increase asbestos concentrations. Closed bales of asbestos may be an emission source. Improving the quality of the wrapping around the bales and handling techniques during shipment are recommended.« less
Fromme, H; Heitmann, D; Dietrich, S; Schierl, R; Körner, W; Kiranoglu, M; Zapf, A; Twardella, D
2008-02-01
Children are assumed to be more vulnerable to health hazards and spend a large part of their time in schools. To assess the exposure situation in this microenvironment, we evaluated the indoor air quality in winter 2004/5 in 92 classrooms, and in 75 classrooms in summer 2005 in south Bavaria, Germany. Indoor air climate parameters (temperature, relative humidity), carbon dioxide (CO2) and various volatile organic compounds, aldehydes and ketones were measured. Additionally, cat allergen (Fel d1) and endotoxin (LAL-test) were analysed in the settled dust of school rooms. Data on room and building characteristics were collected by use of a standardised form. Only data collected during teaching hours were considered in analysis. The median indoor CO2 concentration in the classrooms ranged in the winter and summer period from 598 to 4 172 ppm and 480 to 1 875 ppm, respectively. While during the winter period in 92% of the classrooms the CO2 daily medians went above 1 000 ppm, the percentage of classrooms with increased CO2 concentration fell to 28% in summer. In winter, in 60% of classes the daily median CO2 concentration exceeded 1 500 ppm, while in summer this threshold was reached by only 9%. A high concentration of CO2 was associated with a high number of pupils, a low room surface area and a low room volume. The levels of total volatile organic compounds (TVOC) in classrooms ranged between 110 and 1 000 microg/m3 (median in winter 345 microg/m3, in summer 260 microg/m3). Acetone, formaldehyde and acetaldehyde were measured in concentrations from 14.0 to 911 microg/m3, from 3.1 to 46.1 microg/m3, and from 2.9 to 78 microg/m3, respectively. The other aldehydes were detected in minor amounts only. The median Fel d1 level in winter was 485 ng/g dust (20 to 45 160 ng/g) and in summer it was 417 ng/g (40-7 470 ng/g). We observed no marked differences between the two sampling periods and between smooth floors and rooms with carpeted floors. No differences were found according to room surface area and room volume. The median endotoxin contents in winter and summer were 19.7 EU/mg dust (6.6 to 154 EU/mg) and 32.2 EU/mg (9.6 to 219 EU/mg), respectively. The levels varied significantly between the sampling periods, but were independent of room surface area, room volume and surface floorings. Overall the results of VOC, aldehydes, ketones and endotoxin indicate, in general, a low exposure level in classrooms. The observed concentrations of cat allergens should be considered as a meaningful exposure route and thus could be tackled within preventive programs.
Majumdar, Deepanjan; William, S P M Prince
2009-01-01
The study was undertaken to examine the nature of particulate chalk dust settled on classroom floor during traditional teaching with dusting and non-dusting chalks on two types of boards viz. rough and smooth. Settling chalk particles were collected for 30 min during teaching in glass Petri plates placed in classrooms within 3 m distance from the teaching boards. Particle size distribution, scanning electron microscopic images of chalk dusts and compressive strength of two types of chalks were tested and evaluated. Results showed that a larger proportion of dusts generated from anti-dusting chalks were of <4.5 and <2.5 microm size on both smooth and rough boards, as compared to dusting chalks. Non-dusting chalks, on an average, produced about 56% and 62% (by volume) of <4.5 microm (respirable) diameter, on rough and smooth boards, respectively, while the corresponding values for dusting chalks were 36% and 45%. Also, on an average, 83% and 94% (by volume) of the particles were <11 microm (thoracic) in case of non-dusting chalks against 61% and 72% for dusting chalks on rough and smooth boards, respectively. Interestingly, taking into account the mass of chalk dust produced per unit time, which was higher in dusting chalks than non dusting chalks, the former was actually producing higher amount of PM <4.5 and <11 particles from both types of boards. Scanning electron microscope images revealed that chalk particles had random shape, although in dusting chalks prevalence of elongated particles was observed, apparently due to the longitudinal breaking of the chalks during writing, which was confirmed during compressive strength testing. We could conclude that dusting chalks could be potentially more harmful than anti dusting chalks, as they produced higher amount of potentially dangerous PM 4.5 and PM 11.
Earth Observations taken by the Expedition 16 Crew
2007-10-21
ISS016-E-005526 (21 Oct. 2007) --- Dust plumes, Baja California, Mexico are featured in this image photographed by an Expedition 16 crewmember on the International Space Station. A major dust plume and several minor plumes were raised during the strong, dry Santa Ana winds of October 2007. The light brown dust was transported west out to the Pacific Ocean (top right). According to meteorologists, Santa Ana winds, because they are warm, dry and strong, reduce soil moisture and generate frequent dust storms such as this. On this occasion, the Santa Anas supported the outbreak of fires in southern California resulting in significant damage to homes in hilly, wooded country. Dust plumes are known to start from relatively small, dust-prone areas. Here the plumes rise from the Real del Castillo agricultural valley--25 miles long, and part of Mexico's wine-producing region--surrounded by rocky hills in northern Baja California. Specifically, the dust is rising from spreads of loose sediment known as alluvial fans. Small streams from the local hills carry sediment with every rainstorm and deposit it at the foot of small canyons on the east side of the valley. It is notable that the vegetated farmland itself--the small rectangular pattern on the valley floor--protects the soil from the wind and is not producing dust plumes.
Evaluating the All-Ages Lead Model Using SiteSpecific Data ...
Lead (Pb) exposure continues to be a problem in the United States. Even after years of progress in reducing environmental levels, CDC estimates at least 500,000 U.S. children ages 1-5 years have blood Pb levels (BLL) above the CDC reference level of 5 µg/dL. Childhood Pb exposure is associated with neurological consequences and public health professionals continue to work to reduce Pb exposures. To better understand the relationship between exposure and BLL, the USEPA has developed a beta version of the All-Ages Lead Model (AALM). Compared to the Integrated Exposure Uptake Biokinetics (IEUBK) Model for lead in children, the AALM provides greater flexibility to describe Pb exposures (acute or chronic, constant or intermittent) for any age. At this time, the AALM has the capability to predict exposure in each of the following media: dust/soil, water, air, food, and other. As part of an interagency test group, we evaluated the ability of the AALM beta v4.2 (Leggett version) to predict BLLs for children that were exposed to Pb in their environment near the John T. Lewis and Bros Lead Smelter Superfund site. The model predicted that fourteen children met our inclusion criteria that spent less than 20 hours a week away from the home (e.g., no daycare or school) and had paired BLL and environmental sampling data (i.e., Pb in soil, window sill dust, front door dust, floor dust, and drinking water). The model can predict average BLLs, but it remains difficult to predic
Campbell, D. L. M; Ali, A. B. A; Karcher, D. M; Siegford, J. M
2017-01-01
Abstract The tiered aviary for laying hens includes a floor litter area to promote foraging and dust bathing. Data are needed on hens’ use of different litter substrates and effectiveness of substrates in removing excess feather lipids to ensure a suitable litter area. Bovans White hens were housed in commercial-style aviaries with access to one of 3 litter substrates (wood shavings, straw, or plastic turf mats—AstroTurf®, n = 4 aviary pens per substrate, 144 cage-reared hens populated per pen). Litter areas were videoed across 2 d each at 4 ages: immediately following first aviary opening (25 wk), then at 28, 50, and 68 weeks. Observations of hens throughout the d included percentages of all hens in each pen on the litter area, foraging and transitioning between the tiered enclosure and litter area. Percentages of hens dust bathing were observed from 11:00 to 15:00. Breast and back feather samples from 7 birds per pen at 28, 50, and 68 wk were analyzed for lipid content. Overall, fewer hens simultaneously accessed the AstroTurf® (P < 0.0001), but flocks showed relatively balanced transitions between the tiered enclosure and the litter area throughout the d, regardless of substrate. On average, less than 5% of all hens were observed dust bathing (peaks up to 15% of hens) with no differences among litter substrates or ages (P ≥ 0.18). On average, less than 2% of hens were observed foraging (peaks up to 4% of hens) with fewer hens foraging on AstroTurf® (P < 0.0001). Feather lipid differences among litter substrates (P < 0.0001) were inconsistent across sampling periods, possibly due to different birds sampled across time. At all ages, lipid levels were higher on the back over breast feathers (P < 0.0001) for hens housed with AstroTurf®. AstroTurf® may be suitable for nest boxes, but straw and shavings are more ideal litter substrates. Further study should investigate alternative substrates or regular substrate addition to encourage more foraging and dust bathing. PMID:29050413
Measurement of flow inside a vacuum cleaner head
NASA Astrophysics Data System (ADS)
Iguchi, Ryotaro; Ban, Hisataka; Sakakibara, Jun
2017-11-01
Vacuum cleaner head with rotating brushes is widely used as a home appliance. Although it efficiently collects dusts from the floor, flow field of the air and motion of the dust inside the head have not been fully investigated. In this study, we performed 3D-PIV (particle tracking velocimetry) measurement of velocity field inside the head. Water was used as working fluid, which allows a use of fluorescent particle to reduce unwanted reflection from the brushes and inner surface of the head. Mean velocity field and turbulence statistics in the head with and without the brush will be presented.
NASA Technical Reports Server (NTRS)
2003-01-01
MGS MOC Release No. MOC2-504, 5 October 2003
This August 2003 Mars Global Surveyor (MGS) Mars Orbiter Camera (MOC) image shows a valley near Nilus Chaos, around 25.2oN, 80.3oW. The scene has a uniform albedo, indicating that all of the landforms are probably mantled by fine, bright dust. Dark streaks on the valley walls indicate places where recent dust avalanches have occurred. The ripple-like dune features on the valley floor were formed by wind, but today they are inactive and covered with dust. A few craters, created by impacting debris, have formed on the dunes, again attesting to their inactivity in the modern martian environment. The image covers an area 3 km (1.9 mi) wide; it is illuminated by sunlight from the lower left.This SOP describes the method to collect transferable residues from indoor floor surfaces. The sampling procedures described are applicable to bare floors or covered floor surfaces, e.g., carpeting and vinyl flooring. The samples will be collected only in the day care centers o...
There is an urgent need to characterize potential risk to human health and the environment that arises from the manufacture and use of tens of thousands of chemicals. Computational tools and approaches for characterizing and prioritizing exposure are required: to provide input f...
Brominated flame retardants in offices in Michigan, U.S.A.
Batterman, Stuart; Godwin, Christopher; Chernyak, Sergei; Jia, Chunrong; Charles, Simone
2015-01-01
Brominated flame retardants (BFRs) are now ubiquitous contaminants with large reservoirs and high concentrations in buildings. Most of the information documenting BFR levels has been obtained in residences, and other environments that can lead to exposure have received relatively little attention, including offices that contain numerous BFR sources and where individuals spend considerable time. The aim of this study is to characterize BFR concentrations, potential emission sources, and migration pathways in office environments. We measure BFR levels in floor dust, indoor air, ventilation filter dust, and carpets in ten commercial and institutional buildings in Michigan, U.S.A. The median concentration of total BDEs in settled dust was 8754 ng g−1, at the upper range of levels previously reported. Especially elevated levels were found in offices in buildings that contained known or likely BFR sources, e.g., computer servers. A trends analysis in a newly constructed building showed remarkable increases in concentrations of BFRs in settled dust and indoor air, and apparent steady-state levels were reached 5 to 8 months after building completion, a particularly striking finding given that the building was constructed and furnished several years after the voluntary phase-out of the penta- and octa-mixtures. Airborne particulate matter collected in a building's HVAC system filters contained PBDEs, including BDE-209, at levels exceeding the concentration of floor dust. In conjunction with estimates of building air flow rates, filter efficiency and other parameters, mass balance calculations for this building were used to estimate the emission rates and reservoirs of PBDEs. The widespread distribution of BFRs found in offices in both new and old buildings suggests the significance of workplace exposures, the need for controls to minimize human exposure, intra-building migration, and environmental releases of these chemicals, and the need for monitoring in new buildings to confirm the effectiveness of the PBDE phase-out. PMID:20483456
Loh, Miranda M.; Sugeng, Anastasia; Lothrop, Nathan; Klimecki, Walter; Cox, Melissa; Wilkinson, Sarah T.; Lu, Zhenqiang; Beamer, Paloma I.
2016-01-01
Children living near contaminated mining waste areas may have high exposures to metals from the environment. This study investigates whether exposure to arsenic and lead is higher in children in a community near a legacy mine and smelter site in Arizona compared to children in other parts of the United States and the relationship of that exposure to the site. Arsenic and lead were measured in residential soil, house dust, tap water, urine, and toenail samples from 70 children in 34 households up to 7 miles from the site. Soil and house dust were sieved, digested, and analyzed via ICP-MS. Tap water and urine were analyzed without digestion, while toenails were washed, digested and analyzed. Blood lead was analyzed by an independent, certified laboratory. Spearman correlation coefficients were calculated between each environmental media and urine and toenails for arsenic and lead. Geometric mean arsenic (standard deviation) concentrations for each matrix were: 22.1 (2.59) ppm and 12.4 (2.27) ppm for soil and house dust (<63 μm), 5.71 (6.55) ppb for tap water, 14.0 (2.01) μg/L for specific gravity-corrected total urinary arsenic, 0.543 (3.22) ppm for toenails. Soil and vacuumed dust lead concentrations were 16.9 (2.03) ppm and 21.6 (1.90) ppm. The majority of blood lead levels were below the limit of quantification. Arsenic and lead concentrations in soil and house dust decreased with distance from the site. Concentrations in soil, house dust, tap water, along with floor dust loading were significantly associated with toenail and urinary arsenic but not lead. Mixed models showed that soil and tap water best predicted urinary arsenic. In our study, despite being present in mine tailings at similar levels, internal lead exposure was not high, but arsenic exposure was of concern, particularly from soil and tap water. Naturally occurring sources may be an additional important contributor to exposures in certain legacy mining areas. PMID:26803211
Sudden death caused by 1,1-difluoroethane inhalation.
Xiong, Zhenggang; Avella, Joseph; Wetli, Charles V
2004-05-01
A 20-year-old man was found dead on the floor next to a computer, with a nearly full can of "CRC Duster" dust remover located next to the deceased on the floor, and an empty can of the same product on the computer desk. Toxicologic evaluation using either gas chromatography/mass spectrometry (GC/MS) or gas chromatography/flame ionization detector (GC/FID) method identified the active ingredient 1,1-difluoroethane (Freon 152a) in all tissues analyzed. Tissue distribution studies revealed highest concentration in central blood, lung, and liver. It is believed that the 1,1-difluoroethane inhalation was the cause of death.
Microwave heating apparatus and method
Johnson, Andrew J.; Petersen, Robert D.; Swanson, Stephen D.
1990-01-01
An apparatus is provided for heating and melting materials using microwave energy, and for permitting them to solidify. The apparatus includes a microwave energy source, a resonant cavity having an opening in its floor, a microwave energy choke encompassing the opening in the floor of the cavity, a metal container to hold the materials to be heated and melted, a turntable, and a lift-table. During operation, the combined action of the turntable and the lift-table position the metal container so that the top of the container is level with the floor of the cavity, is in substantial registration with the floor opening, and is encompassed by the microwave energy choke; thus, during operation, the interior of the container defines part of the resonant cavity. Additionally, a screw feeder, extending into the cavity and sheltered from microwave energy by a conveyor choke, may convey the materials to be heated to the container. Also, preferably, the floor of the resonant cavity may include perforatins, so that the offgases and dust generated in the apparatus may be removed from the resonant cavity by pulling outside air between the container choke and the exterior wall of the container into the resonant cavity and out from the cavity through the perforations.
Lunar Dust Separation for Toxicology Studies
NASA Technical Reports Server (NTRS)
Cooper, Bonnie L.; McKay, D. S.; Riofrio, L. M.; Taylor, L. A.; Gonzalex, C. P.
2010-01-01
During the Apollo missions, crewmembers were briefly exposed to dust in the lunar module, brought in after extravehicular activity. When the lunar ascent module returned to micro-gravity, the dust that had settled on the floor now floated into the air, causing eye discomfort and occasional respiratory symptoms. Because our goal is to set an exposure standard for 6 months of episodic exposure to lunar dust for crew on the lunar surface, these brief exposures of a few days are not conclusive. Based on experience with industrial minerals such as sandblasting quartz, an exposure of several months may cause serious damage, while a short exposure may cause none. The detailed characteristics of sub-micrometer lunar dust are only poorly known, and this is the size range of particles that are of greatest concern. We have developed a method for extracting respirable dust (<2.5 micron) from Apollo lunar soils. This method meets stringent requirements that the soil must be kept dry, exposed only to pure nitrogen, and must conserve and recover the maximum amount of both respirable dust and coarser soil. In addition, we have developed a method for grinding coarser lunar soil to produce sufficient respirable soil for animal toxicity testing while preserving the freshly exposed grain surfaces in a pristine state.
A BASIS FOR MODIFYING THE TANK 12 COMPOSITE SAMPLING DESIGN
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shine, G.
The SRR sampling campaign to obtain residual solids material from the Savannah River Site (SRS) Tank Farm Tank 12 primary vessel resulted in obtaining appreciable material in all 6 planned source samples from the mound strata but only in 5 of the 6 planned source samples from the floor stratum. Consequently, the design of the compositing scheme presented in the Tank 12 Sampling and Analysis Plan, Pavletich (2014a), must be revised. Analytical Development of SRNL statistically evaluated the sampling uncertainty associated with using various compositing arrays and splitting one or more samples for compositing. The variance of the simple meanmore » of composite sample concentrations is a reasonable standard to investigate the impact of the following sampling options. Composite Sample Design Option (a). Assign only 1 source sample from the floor stratum and 1 source sample from each of the mound strata to each of the composite samples. Each source sample contributes material to only 1 composite sample. Two source samples from the floor stratum would not be used. Composite Sample Design Option (b). Assign 2 source samples from the floor stratum and 1 source sample from each of the mound strata to each composite sample. This infers that one source sample from the floor must be used twice, with 2 composite samples sharing material from this particular source sample. All five source samples from the floor would be used. Composite Sample Design Option (c). Assign 3 source samples from the floor stratum and 1 source sample from each of the mound strata to each composite sample. This infers that several of the source samples from the floor stratum must be assigned to more than one composite sample. All 5 source samples from the floor would be used. Using fewer than 12 source samples will increase the sampling variability over that of the Basic Composite Sample Design, Pavletich (2013). Considering the impact to the variance of the simple mean of the composite sample concentrations, the recommendation is to construct each sample composite using four or five source samples. Although the variance using 5 source samples per composite sample (Composite Sample Design Option (c)) was slightly less than the variance using 4 source samples per composite sample (Composite Sample Design Option (b)), there is no practical difference between those variances. This does not consider that the measurement error variance, which is the same for all composite sample design options considered in this report, will further dilute any differences. Composite Sample Design Option (a) had the largest variance for the mean concentration in the three composite samples and should be avoided. These results are consistent with Pavletich (2014b) which utilizes a low elevation and a high elevation mound source sample and two floor source samples for each composite sample. Utilizing the four source samples per composite design, Pavletich (2014b) utilizes aliquots of Floor Sample 4 for two composite samples.« less
Teaching-materials study of the elementary science using an extraterrestrial material
NASA Astrophysics Data System (ADS)
Shida, N.; Matsumoto, I.
2013-12-01
The schoolchild of a Japan likes the universe primarily and an inquisitive mind is also considered to be a high. It appears also in children having raised interest concern to astronomical phenomena, such as the space probe "Hayabusa", solar eclipse, and solar Face passage of Venus, in recent Japan. However, generally aside from a child's interest concern, a time and a space concept are difficult for the astronomical phenomenon requested by school education. It is a big problem not only for student but also for teacher. In this presentation, we propose the teaching-materials development which used a meteorite and cosmic dust. Since these teaching materials can touch thing, a student actually taking in his hand, or observing under a microscope, leading to the study understanding accompanied by realization is expected. It looks up at and observes a Star Burst and a constellation. However, acquisition of recognition that it is possible to take in its hand simultaneously and to observe is important. About the meteorite to observe, we can purchase from a special contractor. About cosmic dust, the sample extraction from the concrete floor of the roof of a school building is possible.
NASA Technical Reports Server (NTRS)
2005-01-01
1 September 2005 This Mars Global Surveyor (MGS) Mars Orbiter Camera (MOC) image shows an impact crater cut by troughs which formed after the crater formed. The crater and troughs have large windblown ripples on their floors. The ripples, troughs, craters, and other surfaces in this scene have all been mantled by dust. Dark streaks on slopes indicate areas where avalanches of dry dust have occurred. These features are located on Sacra Mena, a large mesa in the Kasei Valles region. Location near: 25.4oN, 66.8oW Image width: width: 3 km (1.9 mi) Illumination from: lower left Season: Northern AutumnTransport of 2,4-D from the residential lawn into the home was measured following both homeowner and commercial application of this herbicide. Collection of floor dust in five rooms of each house, both prior to and after application, indicated that turf residues are transported...
Comparison of coarse coal dust sampling techniques in a laboratory-simulated longwall section.
Patts, Justin R; Barone, Teresa L
2017-05-01
Airborne coal dust generated during mining can deposit and accumulate on mine surfaces, presenting a dust explosion hazard. When assessing dust hazard mitigation strategies for airborne dust reduction, sampling is done in high-velocity ventilation air, which is used to purge the mining face and gallery tunnel. In this environment, the sampler inlet velocity should be matched to the air stream velocity (isokinetic sampling) to prevent oversampling of coarse dust at low sampler-to-air velocity ratios. Low velocity ratios are often encountered when using low flow rate, personal sampling pumps commonly used in underground mines. In this study, with a goal of employing mine-ready equipment, a personal sampler was adapted for area sampling of coarse coal dust in high-velocity ventilation air. This was done by adapting an isokinetic nozzle to the inlet of an Institute of Occupational Medicine (Edinburgh, Scotland) sampling cassette (IOM). Collected dust masses were compared for the modified IOM isokinetic sampler (IOM-MOD), the IOM without the isokinetic nozzle, and a conventional dust sampling cassette without the cyclone on the inlet. All samplers were operated at a flow rate typical of personal sampling pumps: 2 L/min. To ensure differences between collected masses that could be attributed to sampler design and were not influenced by artifacts from dust concentration gradients, relatively uniform and repeatable dust concentrations were demonstrated in the sampling zone of the National Institute for Occupational Safety and Health experimental mine gallery. Consistent with isokinetic theory, greater differences between isokinetic and non-isokinetic sampled masses were found for larger dust volume-size distributions and higher ventilation air velocities. Since isokinetic sampling is conventionally used to determine total dust concentration, and isokinetic sampling made a difference in collected masses, the results suggest when sampling for coarse coal dust the IOM-MOD may improve airborne coarse dust assessments over "off-the-shelf" sampling cassettes.
Comparison of coarse coal dust sampling techniques in a laboratory-simulated longwall section
Patts, Justin R.; Barone, Teresa L.
2017-01-01
Airborne coal dust generated during mining can deposit and accumulate on mine surfaces, presenting a dust explosion hazard. When assessing dust hazard mitigation strategies for airborne dust reduction, sampling is done in high-velocity ventilation air, which is used to purge the mining face and gallery tunnel. In this environment, the sampler inlet velocity should be matched to the air stream velocity (isokinetic sampling) to prevent oversampling of coarse dust at low sampler-to-air velocity ratios. Low velocity ratios are often encountered when using low flow rate, personal sampling pumps commonly used in underground mines. In this study, with a goal of employing mine-ready equipment, a personal sampler was adapted for area sampling of coarse coal dust in high-velocity ventilation air. This was done by adapting an isokinetic nozzle to the inlet of an Institute of Occupational Medicine (Edinburgh, Scotland) sampling cassette (IOM). Collected dust masses were compared for the modified IOM isokinetic sampler (IOM-MOD), the IOM without the isokinetic nozzle, and a conventional dust sampling cassette without the cyclone on the inlet. All samplers were operated at a flow rate typical of personal sampling pumps: 2 L/min. To ensure differences between collected masses that could be attributed to sampler design and were not influenced by artifacts from dust concentration gradients, relatively uniform and repeatable dust concentrations were demonstrated in the sampling zone of the National Institute for Occupational Safety and Health experimental mine gallery. Consistent with isokinetic theory, greater differences between isokinetic and non-isokinetic sampled masses were found for larger dust volume-size distributions and higher ventilation air velocities. Since isokinetic sampling is conventionally used to determine total dust concentration, and isokinetic sampling made a difference in collected masses, the results suggest when sampling for coarse coal dust the IOM-MOD may improve airborne coarse dust assessments over “off-the-shelf” sampling cassettes. PMID:27792474
Lead dust in Broken Hill homes: effect of remediation on indoor lead levels.
Boreland, F; Lyle, D M
2006-02-01
This study was undertaken to determine whether home remediation effectively reduced indoor lead levels in Broken Hill, a long-established silver-lead-zinc mining town in outback Australia. A before-after study of the effect of home remediation on indoor lead levels was embedded into a randomized controlled trial of the effectiveness of remediation for reducing elevated blood lead levels in young children. Moist towelettes were used to measure lead loading (microg/m2) on internal windowsills and internal and entry floors of 98 homes; samples were collected before, immediately after, and 2, 4, 6, 8, and 10 months after remediation. Data were log(10) transformed for the analysis. Remediation reduced average indoor lead levels by approximately 50%, and lead levels remained low for the duration of the follow-up period (10 months). The greatest gains were made in homes with the highest initial lead levels; homes with low preremediation lead levels showed little or no benefit. Before remediation, homes located in areas with high soil lead levels or with "poor" dust proofing had higher lead levels than those in areas with lower soil lead levels or with "medium" or "good" dust proofing; these relative differences remained after remediation. There was no evidence that lead loading was reduced by an increased opportunity to become aware of lead issues. We conclude that remediation is an effective strategy for reducing the lead exposure of children living in homes with high indoor lead levels.
A simple lead dust fall method predicts children's blood lead level: New evidence from Australia.
Gulson, Brian; Taylor, Alan
2017-11-01
We have measured dust fall accumulation in petri dishes (PDD) collected 6 monthly from inside residences in Sydney urban area, New South Wales, Australia as part of a 5-year longitudinal study to determine environmental associations, including soil. with blood lead (PbB) levels. The Pb loading in the dishes (n = 706) had geometric means (GM) of 24µg/m 2 /30d, a median value of 22µg/m 2 /30d with a range from 0.2 to 11,390µg/m 2 /30d. Observed geometric mean PbB was 2.4µg/dL at ages 2-3 years. Regression analyses showed a statistically significant relationship between predicted PbB and PDD. The predicted PbB values from dust in our study are consistent with similar analyses from the US in which floor dust was collected by wipes. Predicted PbB values from PDD indicate that an increase in PDD of about 100µg/m 2 /30d would increase PbB by about 1.5µg/dL or a doubling PbB at the low levels currently observed in many countries. Predicted PbB values from soil indicate that a change from 0 to 1000mg Pb/kg results in an increase of 1.7µg/dL in PbB, consistent with earlier investigations. Blood Pb levels can be predicted from dust fall accumulation (and soil) in cases where blood sampling is not always possible, especially in young children. Petri dish loading data could provide an alternative or complementary "action level" at about 100µg Pb/m 2 /30 days, similar to the suggested level of about 110µg Pb/m 2 for surface wipes, for use in monitoring activities such as housing rehabilitation, demolition or soil resuspension. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Tang, Kai; Huang, Zhongwei; Huang, Jianping; Maki, Teruya; Zhang, Shuang; Shimizu, Atsushi; Ma, Xiaojun; Shi, Jinsen; Bi, Jianrong; Zhou, Tian; Wang, Guoyin; Zhang, Lei
2018-05-01
Previous studies have shown that bioaerosols are injected into the atmosphere during dust events. These bioaerosols may affect leeward ecosystems, human health, and agricultural productivity and may even induce climate change. However, bioaerosol dynamics have rarely been investigated along the transport pathway of Asian dust, especially in China where dust events affect huge areas and massive numbers of people. Given this situation, the Dust-Bioaerosol (DuBi) Campaign was carried out over northern China, and the effects of dust events on the amount and diversity of bioaerosols were investigated. The results indicate that the number of bacteria showed remarkable increases during the dust events, and the diversity of the bacterial communities also increased significantly, as determined by means of microscopic observations with 4,6-diamidino-2-phenylindole (DAPI) staining and MiSeq sequencing analysis. These results indicate that dust clouds can carry many bacteria of various types into downwind regions and may have potentially important impacts on ecological environments and climate change. The abundances of DAPI-stained bacteria in the dust samples were 1 to 2 orders of magnitude greater than those in the non-dust samples and reached 105-106 particles m-3. Moreover, the concentration ratios of DAPI-stained bacteria to yellow fluorescent particles increased from 5.1 % ± 6.3 % (non-dust samples) to 9.8 % ± 6.3 % (dust samples). A beta diversity analysis of the bacterial communities demonstrated the distinct clustering of separate prokaryotic communities in the dust and non-dust samples. Actinobacteria, Bacteroidetes, and Proteobacteria remained the dominant phyla in all samples. As for Erenhot, the relative abundances of Acidobacteria and Chloroflexi had a remarkable rise in dust events. In contrast, the relative abundances of Acidobacteria and Chloroflexi in non-dust samples of R-DzToUb were greater than those in dust samples. Alphaproteobacteria made the major contribution to the increasing relative abundance of the phylum Proteobacteria in all dust samples. The relative abundance of Firmicutes did not exceed 5 % in all the air samples, even though it is the predominant phylum in the surface sand samples from the Gobi Desert. These results illustrate that the bacterial community contained in dust aerosol samples has a different pattern compared with non-dust aerosol samples, and the relative abundances of airborne bacteria are different from those in the surface sand or soil and differ by location and transmitting vector.
Qian, Peng; Zheng, Xiang-min; Zhou, Li-min
2013-05-01
Atmospheric particulates were sampled from three sampling sites of Putuo, Minhang and Qingpu Districts in Shanghai between Oct. , 2009 and Oct. , 2010. In addition, particulate samples were also collected from Nantong, Zhengzhou, Xi'an, and Beijing city where dust storm dust transported along during spring. Element compositions of atmospheric particulates were determined by XRF and ICP-MS. The concentrations of major and trace elements in atmospheric particulates from Putuo, Minhang and Qingpu Districts were similar, indicating their common source. The UCC standardization distribution map showed that the major element composition of dust storm samples was similar to that of loess in northwestern China, indicating that the dust storm dust was mainly derived from Western desert and partly from local area. The REE partition patterns of dust storm dusts among different cities along dust transport route were similar to each other, as well as to those of northern loess, which indicates that the dust storm samples may have the same material source as loess, which mainly comes from crust material. However, the REE partition patterns of non-dust storm particulates were different among the studied cities, and different from those of loess, which suggests that the non-dust storm samples may be mixed with non-crust source material, which is different from dust storm dust and loess. The major element composition and REE partition pattern are effective indicators for source tracing of dust storm dust.
Speciation of airborne dust from a nickel refinery roasting operation.
Andersen, I; Berge, S R; Resmann, F
1998-04-01
Earlier work-related lung and nasal cancer studies included estimates of exposures to different nickel species in the refinery. Based on the metallurgy, only insoluble nickel was believed to be present around the roasters but mixed exposure was assumed in most areas, including the tankhouse. Occasional leaching tests of samples from the roaster area have indicated the presence of soluble nickel. This study reports on five parallel sets of dust samples collected from different floors with standard equipment and treated as follows. Two sets were leached with an ammonium citrate buffer at pH 4.4. Undissolved material was treated with HClO4/HNO3, evaporated to dryness and dissolved in HCl, Ni, Cu, Co, Fe, Se, and As were determined in both fractions. Water soluble Ni was found in all samples, ranging from 5-35%. Sulfate in the solutions correlated nearly stoichiometrically to the total metal content. The three remaining sets were investigated by, respectively, differential leaching, X-ray diffraction and scanning electron microscopy. The percentage of soluble nickel found by differential leaching corresponded well with those obtained by the simplified procedure. X-Ray diffraction analysis showed the presence of NiSO4.6H2O as well as oxides of Ni and Cu. This study indicates mixed exposures also in the roaster area. It also clearly indicates that basing exposure on the metallurgy alone can lead to serious misjudgements. The impact of this new information on the interpretation of cancer incidence at this refinery must await the analysis in an ongoing case-reference study.
The Martian Story Ares 4 Landing Site
2015-10-05
This image from the High Resolution Imaging Science Experiment (HiRISE) camera on NASA's Mars Reconnaissance Orbiter shows a location on Mars associated with the best-selling novel and Hollywood movie, "The Martian." It is the science-fiction tale's planned landing site for the Ares 4 mission. The novel placed the Ares 4 site on the floor of a very shallow crater in the southwestern corner of Schiaparelli Crater. This HiRISE image shows a flat region there entirely mantled by bright Martian dust. There are no color variations, just uniform reddish dust. A pervasive, pitted texture visible at full resolution is characteristic of many dust deposits on Mars. No boulders are visible, so the dust is probably at least a meter thick. Past Martian rover and lander missions from NASA have avoided such pervasively dust-covered regions for two reasons. First, the dust has a low thermal inertia, meaning that it gets extra warm in the daytime and extra cold at night, a thermal challenge to survival of the landers and rovers (and people). Second, the dust hides the bedrock, so little is known about the bedrock composition and whether it is of scientific interest. This view is one image product from HiRISE observation ESP_042014_1760, taken July 14, 2015, at 3.9 degrees south latitude, 15.2 degrees east longitude. http://photojournal.jpl.nasa.gov/catalog/PIA19914
The mechanics of large meteoroid impacts in the earth's oceans
NASA Technical Reports Server (NTRS)
Melosh, H. J.
1982-01-01
The sequence of events subsequent to the impact of a large meteoroid in an ocean differs in several respects from an impact on land. Even if the meteoroid is large enough to produce a crater on the sea floor (that is, larger than a few km in diameter), the presence of water affects the character of the early-time events. The principal difference between land and oceanic impacts is the expansion of shock-vaporized water following an oceanic impact. A steam explosion follows the meteoroid's deposition of energy in the target. Shocked water expands from an initial pressure of 3 to 6 Mbar for 20-30 km/second impacts, ejecting water vapor and dust from the vaporized meteoroid several hundred km into the atmosphere. The violent vapor plume thus formed may explain how dust with a dominantly meteoritic composition can be dispersed to form a world-wide dust layer, as required by the Alvarez hypothesis.
Schram-Bijkerk, D; Doekes, G; Boeve, M; Douwes, J; Riedler, J; Ublagger, E; von Mutius, E; Benz, M; Pershagen, G; Wickman, M; Alfvén, T; Braun-Fahrländer, C; Waser, M; Brunekreef, B
2006-12-01
Dust collection by study participants instead of fieldworkers would be a practical and cost-effective alternative in large-scale population studies estimating exposure to indoor allergens and microbial agents. We aimed to compare dust weights and biological agent levels in house dust samples taken by study participants with nylon socks, with those in samples taken by fieldworkers using the sampling nozzle of the Allergology Laboratory Copenhagen (ALK). In homes of 216 children, parents and fieldworkers collected house dust within the same year. Dust samples were analyzed for levels of allergens, endotoxin, (1-->3)-beta-D-glucans and fungal extracellular polysaccharides (EPS). Socks appeared to yield less dust from mattresses at relatively low dust amounts and more dust at high dust amounts than ALK samples. Correlations between the methods ranged from 0.47-0.64 for microbial agents and 0.64-0.87 for mite and pet allergens. Cat allergen levels were two-fold lower and endotoxin levels three-fold higher in socks than in ALK samples. Levels of allergens and microbial agents in sock samples taken by study participants are moderately to highly correlated to levels in ALK samples taken by fieldworkers. Absolute levels may differ, probably because of differences in the method rather than in the person who performed the sampling. Practical Implications Dust collection by participants is a reliable and practical option for allergen and microbial agent exposure assessment. Absolute levels of biological agents are not (always) comparable between studies using different dust collection methods, even when expressed per gram dust, because of potential differences in particle-size constitution of the collected dust.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Que Hee, S.S.; Peace, B.; Clark, C.S.
Efficient sampling methods to recover lead-containing house dust and hand dust have been evolved so that sufficient lead is collected for analysis and to ensure that correlational analyses linking these two parameters to blood lead are not dependent on the efficiency of sampling. Precise collection of loose house dust from a 1-unit area (484 cmS) with a Tygon or stainless steel sampling tube connected to a portable sampling pump (1.2 to 2.5 liters/min) required repetitive sampling (three times). The Tygon tube sampling technique for loose house dust <177 m in diameter was around 72% efficient with respect to dust weightmore » and lead collection. A representative house dust contained 81% of its total weight in this fraction. A single handwipe for applied loose hand dust was not acceptably efficient or precise, and at least three wipes were necessary to achieve recoveries of >80% of the lead applied. House dusts of different particle sizes <246 m adhered equally well to hands. Analysis of lead-containing material usually required at least three digestions/decantations using hot plate or microwave techniques to allow at least 90% of the lead to be recovered. It was recommended that other investigators validate their handwiping, house dust sampling, and digestion techniques to facilitate comparison of results across studies. The final methodology for the Cincinnati longitudinal study was three sampling passes for surface dust using a stainless steel sampling tube; three microwave digestion/decantations for analysis of dust and paint; and three wipes with handwipes with one digestion/decantation for the analysis of six handwipes together.« less
Campbell, D L M; Ali, A B A; Karcher, D M; Siegford, J M
2017-09-01
The tiered aviary for laying hens includes a floor litter area to promote foraging and dust bathing. Data are needed on hens' use of different litter substrates and effectiveness of substrates in removing excess feather lipids to ensure a suitable litter area. Bovans White hens were housed in commercial-style aviaries with access to one of 3 litter substrates (wood shavings, straw, or plastic turf mats-AstroTurf®, n = 4 aviary pens per substrate, 144 cage-reared hens populated per pen). Litter areas were videoed across 2 d each at 4 ages: immediately following first aviary opening (25 wk), then at 28, 50, and 68 weeks. Observations of hens throughout the d included percentages of all hens in each pen on the litter area, foraging and transitioning between the tiered enclosure and litter area. Percentages of hens dust bathing were observed from 11:00 to 15:00. Breast and back feather samples from 7 birds per pen at 28, 50, and 68 wk were analyzed for lipid content. Overall, fewer hens simultaneously accessed the AstroTurf® (P < 0.0001), but flocks showed relatively balanced transitions between the tiered enclosure and the litter area throughout the d, regardless of substrate. On average, less than 5% of all hens were observed dust bathing (peaks up to 15% of hens) with no differences among litter substrates or ages (P ≥ 0.18). On average, less than 2% of hens were observed foraging (peaks up to 4% of hens) with fewer hens foraging on AstroTurf® (P < 0.0001). Feather lipid differences among litter substrates (P < 0.0001) were inconsistent across sampling periods, possibly due to different birds sampled across time. At all ages, lipid levels were higher on the back over breast feathers (P < 0.0001) for hens housed with AstroTurf®. AstroTurf® may be suitable for nest boxes, but straw and shavings are more ideal litter substrates. Further study should investigate alternative substrates or regular substrate addition to encourage more foraging and dust bathing. © The Author 2017. Published by Oxford University Press on behalf of Poultry Science Association.
Semivolatile compounds in schools and their influence on cognitive performance of children.
Hutter, Hans-Peter; Haluza, Daniela; Piegler, Kathrin; Hohenblum, Philipp; Fröhlich, Marina; Scharf, Sigrid; Uhl, Maria; Damberger, Bernhard; Tappler, Peter; Kundi, Michael; Wallner, Peter; Moshammer, Hanns
2013-08-01
WHO's Children's Environment and Health Action Plan for Europe (CEHAPE) focuses on improvements of indoor environments where children spend most of their time. To investigate the relationship between school indoor air pollutants and cognitive performance in elementary school children, a multidisciplinary study was planned in all-day schools in Austria. In a cross-sectional study (LuKi study: Air and Children) indoor air pollutants were monitored in nine elementary all-day schools in urban and rural regions of Austria. In addition, school dust and suspended particulates (PM10, PM2.5) were measured, focusing on semivolatile compounds (e.g. phthalates, phosphororganic compounds [POC]). Health status and environmental conditions were determined by parents' questionnaire, cognitive function was measured by Standard Progressive Matrices (SPM). Overall, 596 children (6-8 years of age) were eligible for the study. Cognitive tests were performed in 436 children. Analysis showed significant correlations of tris(2-chlorethyl)-phosphate (TCEP) in PM10 and PM2.5 and school dust samples with cognitive performance. Cognitive performance decreased with increasing concentrations of TCEP. Furthermore, cognitive function decreased significantly with increasing CO2 levels. POC are widely used as plasticizers, flame retardants and floor sealing. This is the first report of a correlation between TCEP in indoor air samples and impairment of cognitive performance in school children. As a precautionary measure, it is recommended to prohibit the use of toxic chemicals and those suspected of a toxic potential in children's environments such as schools.
Swaddiwudhipong, Witaya; Kavinum, Suporn; Papwijitsil, Ratchadaporn; Tontiwattanasap, Worawit; Khunyotying, Wanlee; Umpan, Jiraporn; BoonthuM, Ratchaneekorn; Kaewnate, Yingyot; Boonmee, Sasis; Thongchub, Winai; Rodsung, Thassanee
2014-11-01
A community-based study was conducted to determine personal risk factors and environmental sources of lead exposure for elevated blood lead levels (≥ 10 µg/dl, EBLLs) among rural children living at the Thailand-Myanmar border in Tak Province, northwestern Thailand. Six hundred ninety-five children aged 1-14 years old were screened for BLLs. Environmental specimens for lead measurements included samples of water from the streams, taps, and household containers, house floor dust, and foods. Possible lead release from the cooking ware was determined using the leaching method with acetic acid. The overall prevalence of EBLLs was 47.1% and the geometric mean level of blood lead was 9.16 µg/dl. Personal risk factors significantly associated with EBLLs included being male, younger age, anemia, and low weight-for-age. Significant environmental risk factors were exposure to a lead-acid battery of solar energy system and use of a non-certified metal cooking pot. Some families whose children had high BLLs reported production of lead bullets from the used batteries at home. About one-third of the house dust samples taken near batteries contained lead content above the recommended value, compared with none of those taken from other areas and from the houses with no batteries. The metal pots were safe for cooking rice but might be unsafe for acidic food preparation. Both nutritional intervention and lead exposure prevention programs are essential to reduce EBLLs in this population.
Overview of the Atmosphere and Environment within Gale Crater on Mars
NASA Astrophysics Data System (ADS)
Vasavada, A. R.; Grotzinger, J. P.; Crisp, J. A.; Gomez-Elvira, J.; Mahaffy, P. R.; Webster, C. R.
2012-12-01
Curiosity's mission at Gale Crater places a number of highly capable atmospheric and environmental sensors within a dynamic setting: next to a 5-km mountain within a 150-km diameter impact crater whose floor is -4.5 km. Curiosity's scientific payload was chosen primarily to allow a geologic and geochemical investigation of Mars' environmental history and habitability, as preserved in the layered sediments on the crater floor and mound. Atmospheric and environmental sensors will contribute by measuring the bulk atmospheric chemical and isotopic composition, the flux of high-energy particle and ultraviolet radiation after modification by the atmosphere, and modern processes related to meteorology and climate over at least one Mars year. The Sample Analysis at Mars instrument will analyze the atmosphere with its mass spectrometer and tunable laser spectrometer. The former is capable of providing bulk composition and isotopic ratios of relevance to planetary evolution, such as nitrogen and noble gases. The latter is designed to acquire high-precision measurements of atmospheric species including CH4, CO2, and H2O, and key isotope ratios in H, C, and O. An important goal will be to compare CH4 abundance and time variability over the mission with the reported detections from the Mars Express orbiter and ground-based observations. The Radiation Assessment Detector (RAD) measures a broad spectrum of high-energy radiation incident at the surface, including secondary particles created via interactions of galactic cosmic rays and solar protons with Mars' atmospheric constituents. Curiosity's Rover Environmental Monitoring Station (REMS) carries six ultraviolet sensors, spanning 200-380 nm. For the first time, both the high-energy and ultraviolet radiation measured at the surface can be compared with measurements above the atmosphere, acquired by other platforms. Modern meteorology and the climatology of dust and water will be studied using the rover's cameras and REMS instrument package. The Mast Cameras are equipped with filters to allow optical measurements of dust and water ice aerosol opacity. Sky images and video clips will illuminate winds (via aerosols) and the dynamics of water ice and dust, including dust devils and dust storms. REMS can measure wind speed and direction in three dimensions, atmospheric pressure, air temperature, ground temperature, and humidity around the clock, independent of the rover's wake/sleep cycles. The meteorological measurements of REMS will be especially interesting given the setting at Gale Crater. Mesoscale modeling of the site indicates a strong influence of the regional topography. As the rover traverses toward Mount Sharp, it will sample different portions of a complex wind field forced by diurnal heating of the surface, ascending and descending catabatic flows from the crater wall and Mt. Sharp, and influences of local variations in albedo, thermal inertia, and topography. The combination of a broad meteorological package, a mobile rover, and a topographically diverse site will provide a wealth of raw data for understanding joint influences of the atmosphere and the surface. For example, orbital imagery indicates active dune migration at the margins of Mt. Sharp. REMS will illuminate the present-day surface stress of winds as a function of position, time, and season. Such correlations are key to understanding the geologic processes that have shaped Mount Sharp and Gale Crater.
NASA Astrophysics Data System (ADS)
Palchan, Daniel; Stein, Mordechai; Goldstein, Steven L.; Almogi-Labin, Ahuva; Tirosh, Ofir; Erel, Yigal
2018-01-01
The sediments deposited at the depocenter of the Dead Sea comprise high-resolution archive of hydrological changes in the lake's watershed and record the desert dust transport to the region. This paper reconstructs the dust transport to the region during the termination of glacial Marine Isotope Stage 6 (MIS 6; ∼135-129 ka) and the last interglacial peak period (MIS5e, ∼129-116 ka). We use chemical and Nd and Sr isotope compositions of fine detritus material recovered from sediment core drilled at the deepest floor of the Dead Sea. The data is integrated with data achieved from cores drilled at the floor of the Red Sea, thus, forming a Red Sea-Dead Sea transect extending from the desert belt to the Mediterranean climate zone. The Dead Sea accumulated flood sediments derived from three regional surface cover types: settled desert dust, mountain loess-soils and loess-soils filling valleys in the Dead Sea watershed termed here "Valley Loess". The Valley Loess shows a distinct 87Sr/86Sr ratio of 0.7081 ± 1, inherited from dissolved detrital calcites that originate from dried waterbodies in the Sahara and are transported with the dust to the entire transect. Our hydro-climate and synoptic conditions reconstruction illustrates the following history: During glacial period MIS6, Mediterranean cyclones governed the transport of Saharan dust and rains to the Dead Sea watershed, driving the development of both mountain soils and Valley Loess. Then, at Heinrich event 11, dry western winds blew Saharan dust over the entire Red Sea - Dead Sea transect marking latitudinal expansion of the desert belt. Later, when global sea-level rose, the Dead Sea watershed went through extreme aridity, the lake retreated, depositing salt and accumulating fine detritus of the Valley Loess. During peak interglacial MIS 5e, enhanced flooding activity flushed the mountain soils and fine detritus from all around the Dead Sea and Red Sea, marking a significant "contraction" of the desert belt. At the end of MIS 5e the effect of the regional precipitation diminished and the Dead Sea and Red Sea areas re-entered sever arid conditions with extensive salt deposition at the Dead Sea.
Microbiological and meteorological analysis of two Australian dust storms in April 2009.
Lim, Natalie; Munday, Chris I; Allison, Gwen E; O'Loingsigh, Tadhg; De Deckker, Patrick; Tapper, Nigel J
2011-12-15
Dust is an important source of bioaerosols including bacteria. In this study, the microbiology and meteorology of specific dust storms in Australia were investigated. The samples were collected from two dust events in April 2009 that were characterised by intense cold fronts that entrained dust from the highly erodible and drought-stricken Mallee and Riverina regions of Victoria and central NSW. In the first storm, the dust travelled eastward over Canberra and Sydney, and in the second storm, the dust travelled east/southeastward over Canberra and Melbourne. Rain fell on both cities during the second dust storm. Dust and rain samples were collected, cultured, and the composition compared using polymerase chain reaction denaturing gradient gel electrophoresis (PCR-DGGE). Multiple bands were evident on DGGE indicative of a diverse microflora, and identification of several bands confirmed the presence of multiple genera and species representing three phyla. Numerous bands represented Bacillus species, and these were present in multiple dust samples collected from both Canberra and Melbourne. Interestingly, the microflora present in rain samples collected in Canberra during the second dust storm was quite different and the DGGE banding patterns from these samples clustered separately to most dust samples collected at the same time. Identification of several DGGE bands and PCR products from these rain samples indicated the presence of Pseudomonas species. These results indicate that Australian dust and rain have a diverse microflora and highlights the contribution of dust events to the distribution of microbes in the environment. Copyright © 2011 Elsevier B.V. All rights reserved.
Lack of viable seeds in the forest floor after clearcutting
Robert M. Frank; Lawrence O. Safford
1970-01-01
The viability of seeds o[ northern conifers apparently does not persist in the forest floor for more than one year. A set of forest-floor samples collected two years alter a heavy seed crop and one year alter a seedcrop failure did not produce any conifer germinants, regardless of whether or not the surfaces of the samples were disturbed. A second set of forest-floor...
Investigating Mars: Tithonium Chasma
2018-02-06
This VIS image shows part of Tithonium Chasma. The ridge visible at the top of the image is not the top of the canyon. The top of the canyon is off the image to the north. A lobate "tongue" visible between the ridge and the top of the canyon is the deposit left by a landslide event. This material is more resistant and forms the ridges extending down the canyon walls. Eroded materials cover much of the canyon floor. The initial formation of layered floor desposits was possibly created of air fall of dust, sand, and volcanic materials and water lain materials. The weathering of these deposits is probably by the wind. Loose sand and dust can be seen in other portions of this image. Tithonium Chasma is at the western end of Valles Marineris. Valles Marineris is over 4000 kilometers long, wider than the United States. Tithonium Chasma is almost 810 kilometers long (499 miles), 50 kilometers wide and over 6 kilometers deep. In comparison, the Grand Canyon in Arizona is about 175 kilometers long, 30 kilometers wide, and only 2 kilometers deep. The canyons of Valles Marineris were formed by extensive fracturing and pulling apart of the crust during the uplift of the vast Tharsis plateau. Landslides have enlarged the canyon walls and created deposits on the canyon floor. Weathering of the surface and influx of dust and sand have modified the canyon floor, both creating and modifying layered materials. The Odyssey spacecraft has spent over 15 years in orbit around Mars, circling the planet more than 71,000 times. It holds the record for longest working spacecraft at Mars. THEMIS, the IR/VIS camera system, has collected data for the entire mission and provides images covering all seasons and lighting conditions. Over the years many features of interest have received repeated imaging, building up a suite of images covering the entire feature. From the deepest chasma to the tallest volcano, individual dunes inside craters and dune fields that encircle the north pole, channels carved by water and lava, and a variety of other feature, THEMIS has imaged them all. For the next several months the image of the day will focus on the Tharsis volcanoes, the various chasmata of Valles Marineris, and the major dunes fields. We hope you enjoy these images! Orbit Number: 3212 Latitude: -4.46108 Longitude: 271.004 Instrument: VIS Captured: 2002-09-04 22:56 https://photojournal.jpl.nasa.gov/catalog/PIA22268
Yiin, Lih-Ming; Millette, James R; Vette, Alan; Ilacqua, Vito; Quan, Chunli; Gorczynski, John; Kendall, Michaela; Chen, Lung Chi; Weisel, Clifford P; Buckley, Brian; Yang, Ill; Lioy, Paul J
2004-05-01
The collapse of the World Trade Center (WTC) on September 11, 2001, generated large amounts of dust and smoke that settled in the surrounding indoor and outdoor environments in southern Manhattan. Sixteen dust samples were collected from undisturbed locations inside two uncleaned buildings that were adjacent to Ground Zero. These samples were analyzed for morphology, metals, and organic compounds, and the results were compared with the previously reported outdoor WTC dust/smoke results. We also analyzed seven additional dust samples provided by residents in the local neighborhoods. The morphologic analyses showed that the indoor WTC dust/smoke samples were similar to the outdoor WTC dust/smoke samples in composition and characteristics but with more than 50% mass in the <53-microm size fraction. This was in contrast to the outdoor samples that contained >50% of mass above >53 microm. Elemental analyses also showed the similarities, but at lower concentrations. Organic compounds present in the outdoor samples were also detected in the indoor samples. Conversely, the resident-provided convenience dust samples were different from either the WTC indoor or outdoor samples in composition and pH, indicating that they were not WTC-affected locations. In summary, the indoor dust/smoke was similar in concentration to the outdoor dust/smoke but had a greater percentage of mass <53 microm in diameter.
A Submillimeter Continuum Survey of Local Dust-obscured Galaxies
NASA Astrophysics Data System (ADS)
Lee, Jong Chul; Hwang, Ho Seong; Lee, Gwang-Ho
2016-12-01
We conduct a 350 μm dust continuum emission survey of 17 dust-obscured galaxies (DOGs) at z = 0.05-0.08 with the Caltech Submillimeter Observatory (CSO). We detect 14 DOGs with S 350 μm = 114-650 mJy and signal-to-noise > 3. By including two additional DOGs with submillimeter data in the literature, we are able to study dust content for a sample of 16 local DOGs, which consist of 12 bump and four power-law types. We determine their physical parameters with a two-component modified blackbody function model. The derived dust temperatures are in the range 57-122 K and 22-35 K for the warm and cold dust components, respectively. The total dust mass and the mass fraction of the warm dust component are 3-34 × 107 M ⊙ and 0.03%-2.52%, respectively. We compare these results with those of other submillimeter-detected infrared luminous galaxies. The bump DOGs, the majority of the DOG sample, show similar distributions of dust temperatures and total dust mass to the comparison sample. The power-law DOGs show a hint of smaller dust masses than other samples, but need to be tested with a larger sample. These findings support that the reason DOGs show heavy dust obscuration is not an overall amount of dust content, but probably the spatial distribution of dust therein.
Effect of ground control mesh on dust sampling and explosion mitigation.
Alexander, D W; Chasko, L L
2015-07-01
Researchers from the National Institute for Occupational Safety and Health's Office of Mine Safety and Health Research conducted an assessment of the effects that ground control mesh might have on rock and float coal dust distribution in a coal mine. The increased use of mesh to control roof and rib spall introduces additional elevated surfaces on which rock or coal dust can collect. It is possible to increase the potential for dust explosion propagation if any float coal dust is not adequately inerted. In addition, the mesh may interfere with the collection of representative dust samples when using the pan-and-brush sampling method developed by the U.S. Bureau of Mines and used by the Mine Safety and Health Administration for band sampling. This study estimates the additional coal or rock dust that could accumulate on mesh and develops a means to collect representative dust samples from meshed entries.
Effect of ground control mesh on dust sampling and explosion mitigation
Alexander, D.W.; Chasko, L.L.
2017-01-01
Researchers from the National Institute for Occupational Safety and Health’s Office of Mine Safety and Health Research conducted an assessment of the effects that ground control mesh might have on rock and float coal dust distribution in a coal mine. The increased use of mesh to control roof and rib spall introduces additional elevated surfaces on which rock or coal dust can collect. It is possible to increase the potential for dust explosion propagation if any float coal dust is not adequately inerted. In addition, the mesh may interfere with the collection of representative dust samples when using the pan-and-brush sampling method developed by the U.S. Bureau of Mines and used by the Mine Safety and Health Administration for band sampling. This study estimates the additional coal or rock dust that could accumulate on mesh and develops a means to collect representative dust samples from meshed entries. PMID:28936000
Cha, Seho; Srinivasan, Sathiyaraj; Jang, Jun Hyeong; Lee, Dongwook; Lim, Sora; Kim, Kyung Sang; Jheong, Weonhwa; Lee, Dong-Won; Park, Eung-Roh; Chung, Hyun-Mi; Choe, Joonho; Kim, Myung Kyum; Seo, Taegun
2017-01-01
Asian dust or yellow sand events in East Asia are a major issue of environmental contamination and human health, causing increasing concern. A high amount of dust particles, especially called as particulate matter 10 (PM10), is transported by the wind from the arid and semi-arid tracks to the Korean peninsula, bringing a bacterial population that alters the terrestrial and atmospheric microbial communities. In this study, we aimed to explore the bacterial populations of Asian dust samples collected during November-December 2014. The dust samples were collected using the impinger method, and the hypervariable regions of the 16S rRNA gene were amplified using PCR followed by pyrosequencing. Analysis of the sequencing data were performed using Mothur software. The data showed that the number of operational taxonomic units and diversity index during Asian dust events were higher than those during non-Asian dust events. At the phylum level, the proportions of Proteobacteria, Actinobacteria, and Firmicutes were different between Asian dust and non-Asian dust samples. At the genus level, the proportions of the genus Bacillus (6.9%), Arthrobacter (3.6%), Blastocatella (2%), Planomicrobium (1.4%) were increased during Asian dust compared to those in non-Asian dust samples. This study showed that the significant relationship between bacterial populations of Asian dust samples and non-Asian dust samples in Korea, which could significantly affect the microbial population in the environment.
Cha, Seho; Srinivasan, Sathiyaraj; Jang, Jun Hyeong; Lee, Dongwook; Lim, Sora; Kim, Kyung Sang; Jheong, Weonhwa; Lee, Dong-Won; Park, Eung-Roh; Chung, Hyun-Mi; Choe, Joonho; Kim, Myung Kyum; Seo, Taegun
2017-01-01
Asian dust or yellow sand events in East Asia are a major issue of environmental contamination and human health, causing increasing concern. A high amount of dust particles, especially called as particulate matter 10 (PM10), is transported by the wind from the arid and semi-arid tracks to the Korean peninsula, bringing a bacterial population that alters the terrestrial and atmospheric microbial communities. In this study, we aimed to explore the bacterial populations of Asian dust samples collected during November–December 2014. The dust samples were collected using the impinger method, and the hypervariable regions of the 16S rRNA gene were amplified using PCR followed by pyrosequencing. Analysis of the sequencing data were performed using Mothur software. The data showed that the number of operational taxonomic units and diversity index during Asian dust events were higher than those during non-Asian dust events. At the phylum level, the proportions of Proteobacteria, Actinobacteria, and Firmicutes were different between Asian dust and non-Asian dust samples. At the genus level, the proportions of the genus Bacillus (6.9%), Arthrobacter (3.6%), Blastocatella (2%), Planomicrobium (1.4%) were increased during Asian dust compared to those in non-Asian dust samples. This study showed that the significant relationship between bacterial populations of Asian dust samples and non-Asian dust samples in Korea, which could significantly affect the microbial population in the environment. PMID:28122054
Lead isotopes and trace metals in dust at Yucca Mountain
Kwak, Loretta; Neymark, Leonid A.; Peterman, Zell E.
2008-01-01
Lead (Pb)-isotope compositions and trace-metal concentrations were determined for samples of dust collected from underground and surface locations at and near the proposed radioactive waste repository at Yucca Mountain, Nevada. Rare earth element concentrations in the dust samples from the underground tunnels are similar to those in wholerock samples of the repository host rocks (Miocene Tiva Canyon Tuff and Topopah Spring Tuff), supporting interpretation that the subsurface dust is mainly composed of rock comminuted during tunnel construction. Other trace metals (arsenic, cadmium, cobalt, chromium, copper, manganese, nickel, lead, antimony, thallium, and zinc) are variably enriched in the subsurface dust samples relative to the average concentrations in the host rocks. Average concentrations of arsenic and lead in dust samples, high concentrations of which can cause corrosion of waste canisters, have enrichment factors from 1.2 to 1.6 and are insignificant relative to the range of concentrations for these metals observed in the host rock samples. Most dust samples from surface sites also are enriched in many of these trace metals relative to average repository host rocks. At least some of these enrichments may be artifacts of sampling. Plotted on a 208Pb/206Pb-207Pb/206Pb graph, Pb-isotope compositions of dust samples from underground sites form a mixing line extending from host-rock Pb-isotope compositions towards compositions of many of the dust samples from surface sites; however, combined Pb concentration and isotope data indicate the presence of a Pbenriched component in the subsurface dust that is not derived from host rock or surface dust and may derive from anthropogenic materials introduced into the underground environment.
3 MV hypervelocity dust accelerator at the Colorado Center for Lunar Dust and Atmospheric Studies.
Shu, Anthony; Collette, Andrew; Drake, Keith; Grün, Eberhard; Horányi, Mihály; Kempf, Sascha; Mocker, Anna; Munsat, Tobin; Northway, Paige; Srama, Ralf; Sternovsky, Zoltán; Thomas, Evan
2012-07-01
A hypervelocity dust accelerator for studying micrometeorite impacts has been constructed at the Colorado Center for Lunar Dust and Atmospheric Studies (CCLDAS) at the University of Colorado. Based on the Max-Planck-Institüt für Kernphysik (MPI-K) accelerator, this accelerator is capable of emitting single particles of a specific mass and velocity selected by the user. The accelerator consists of a 3 MV Pelletron generator with a dust source, four image charge pickup detectors, and two interchangeable target chambers: a large high-vacuum test bed and an ultra-high vacuum impact study chamber. The large test bed is a 1.2 m diameter, 1.5 m long cylindrical vacuum chamber capable of pressures as low as 10(-7) torr while the ultra-high vacuum chamber is a 0.75 m diameter, 1.1 m long chamber capable of pressures as low as 10(-10) torr. Using iron dust of up to 2 microns in diameter, final velocities have been measured up to 52 km/s. The spread of the dust particles and the effect of electrostatic focusing have been measured using a long exposure CCD and a quartz target. Furthermore, a new technique of particle selection is being developed using real time digital filtering techniques. Signals are digitized and then cross-correlated with a shaped filter, resulting in a suppressed noise floor. Improvements over the MPI-K design, which include a higher operating voltage and digital filtering for detection, increase the available parameter space of dust emitted by the accelerator. The CCLDAS dust facility is a user facility open to the scientific community to assist with instrument calibrations and experiments.
Endotoxin in inner-city homes: associations with wheeze and eczema in early childhood.
Perzanowski, Matthew S; Miller, Rachel L; Thorne, Peter S; Barr, R Graham; Divjan, Adnan; Sheares, Beverley J; Garfinkel, Robin S; Perera, Frederica P; Goldstein, Inge F; Chew, Ginger L
2006-05-01
An inverse association between domestic exposure to endotoxin and atopy in childhood has been observed. The relevance of this aspect of the hygiene hypothesis to US inner-city communities that have disproportionately high asthma prevalence has not been determined. To measure endotoxin in the dust from inner-city homes, evaluate associations between endotoxin and housing/lifestyle characteristics, and determine whether endotoxin exposure predicted wheeze, allergic rhinitis, and eczema over the first 3 years of life. As part of an ongoing prospective birth cohort study, children of Dominican and African-American mothers living in New York City underwent repeated questionnaire measures. Dust samples collected from bedroom floors at age 12 or 36 months were assayed for endotoxin. Among the samples collected from 301 participants' homes, the geometric mean endotoxin concentration (95% CI) was 75.9 EU/mg (66-87), and load was 3892 EU/m2 (3351-4522). Lower endotoxin concentrations were associated with wet mop cleaning and certain neighborhoods. Endotoxin concentration correlated weakly with cockroach (Bla g 2: r = 0.22, P < .001) and mouse (mouse urinary protein: r = 0.28; P < .001) allergens in the dust. Children in homes with higher endotoxin concentration were less likely to have eczema at age 1 year (odds ratio, 0.70 [0.53-0.93]) and more likely to wheeze at age 2 years (odds ratio, 1.34 [1.01-1.78]). These associations were stronger among children with a maternal history of asthma. Endotoxin levels in this inner-city community are similar to those in nonfarm homes elsewhere. In this community, domestic endotoxin exposure was inversely associated with eczema at age 1 year, but positively associated with wheeze at age 2 years. Endotoxin exposure in the inner-city community may be related to wheeze in the early life; however, given the inverse association seen with eczema, the long-term development of allergic disease is still in question.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-28
... for OMB Review; Comment Request; Respirable Coal Mine Dust Sampling ACTION: Notice. SUMMARY: The... information collection request (ICR) titled, ``Respirable Coal Mine Dust Sampling,'' to the Office of... operator to protect miners from exposure to excessive dust levels. The respirable coal mine dust sampling...
Krysińska-Traczyk, Ewa; Perkowski, Juliusz; Dutkiewicz, Jacek
2007-01-01
During combine harvesting of 5 various cereal crops (rye, barley, oats, buckwheat, corn) 24 samples of grain and 24 samples of settled grain dust were collected on farms located in the Lublin province of eastern Poland. The samples were examined for the concentration of total microfungi, Fusarium species, deoxynivalenol (DON), nivalenol (NIV), and ochratoxin A (OTA). Microfungi able to grow on malt agar were present in 79.2% of grain samples and in 91.7% of grain dust samples in the concentrations of 1.0-801.3x10(3) cfu/g and 1.5-12440.0x10(3) cfu/g, respectively. The concentration of microfungi in grain dust samples was significantly greater than in grain samples (p<0.01). Fusarium strains were isolated from 54.2% of grain samples and from 58.3% of grain dust samples in the concentrations of 0.1-375.0x10(3) cfu/g and 4.0-7,700.0x10(3) cfu/g, respectively. They were found in all samples of grain and grain dust from rye, barley and corn, but only in 0-16.7% of samples of grain and grain dust from oats and buckwheat. DON was found in 79.2% of grain samples and in 100% of grain dust samples in the concentrations of 0.001-0.18 microg/g and 0.006-0.283 microg/g, respectively. NIV was detected in 62.5% of grain samples and in 94.4% of grain dust samples in the concentrations of 0.004-0.502 microg/g and 0.005-0.339 microg/g, respectively. OTA was detected in 58.3% of grain samples and in 91.7% of grain dust samples in the concentrations of 0.00039- 0.00195 microg/g and 0.00036-0.00285 microg/g, respectively. The concentrations of DON, total fusariotoxins (DON+NIV) and OTA were significantly greater in grain dust samples than in grain samples (p<0.05, p<0.05, and p<0.001, respectively). The concentration of Fusarium poae in the samples of rye grain and dust was significantly correlated with the concentrations of DON (p<0.05), NIV (p<0.01), and total fusariotoxins (p<0.05). Similarly, the concentration of Fusarium culmorum in the samples of barley grain and dust was significantly correlated with the concentration of total fusariotoxins (p<0.05). A significant correlation was also found between the concentration of total fungi grown on malt agar and the concentration of OTA (p<0.05). In conclusion, although the concentration of DON, NIV and OTA in the samples of grain dust collected from 5 various cereals on farms in eastern Poland was not large, the persistent presence of these mycotoxins in over 90% of examined samples poses a potential health risk of chronic respiratory intoxication for exposed grain farmers.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kendall, J.; Hams, J.E.; Buck, S.P.
1990-05-01
Advances in high resolution side-scan sonar imaging technology are so effective at imaging sea-floor geology that they have greatly improved the efficiency of a bottom sampling program The traditional sea-floor geology methodology of shooting a high-resolution seismic survey and sampling along the seismic grid was considered successful if outcrops were sampled on 20% of the attempts. A submersible was used sparingly because of the inability to consistently locate sea-floor outcrops. Side-scan sonar images have increased the sampling success ratio to 70-95% and allow the cost-effective use of a submersible even in areas of sparse sea-floor outcrops. In offshore basins thismore » new technology has been used in consolidated and semiconsolidated rock terranes. When combined with observations from a two-man submersible, SCUBA traverses, seismic data, and traditional sea-floor bottom sampling techniques, enough data are provided to develop an integrated sea-floor geologic interpretation. On individual prospects, side-scan sonar has aided the establishment of critical dip in poor seismic data areas, located seeps and tar mounds, and determined erosional breaching of a prospect. Over a mature producing field, side-scan sonar has influenced the search for field extension by documenting the orientation and location of critical trapping cross faults. These relatively inexpensive techniques can provide critical data in any marine basin where rocks crop out on the sea floor.« less
NASA Astrophysics Data System (ADS)
Durda, Daniel D.; Flynn, George J.; Sandel, L. Erica; Strait, Melissa M.
2007-01-01
We present mass-frequency data for fragments from the impact disruption of four chondritic meteorites, extending to masses several orders of magnitude smaller the mass-frequency data that are usually measured in similar impact experiments. Masses of mm- to cm-scale fragments were determined by directly weighing debris collected from the floor of the Ames Vertical Gun Range impact chamber. Masses of sub-mm to dust-size fragments were determined from analysis of foil penetration data. The mass-frequency distributions display a range of morphologies ranging from nearly linear power-law distributions to `broken' power laws with progressively shallower slopes at smaller fragment masses, apparently dependent on the magnitude of the impact specific energy.
A SUBMILLIMETER CONTINUUM SURVEY OF LOCAL DUST-OBSCURED GALAXIES
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Jong Chul; Hwang, Ho Seong; Lee, Gwang-Ho, E-mail: jclee@kasi.re.kr
We conduct a 350 μ m dust continuum emission survey of 17 dust-obscured galaxies (DOGs) at z = 0.05–0.08 with the Caltech Submillimeter Observatory (CSO). We detect 14 DOGs with S{sub 350μm} = 114–650 mJy and signal-to-noise > 3. By including two additional DOGs with submillimeter data in the literature, we are able to study dust content for a sample of 16 local DOGs, which consist of 12 bump and four power-law types. We determine their physical parameters with a two-component modified blackbody function model. The derived dust temperatures are in the range 57–122 K and 22–35 K for themore » warm and cold dust components, respectively. The total dust mass and the mass fraction of the warm dust component are 3–34 × 10{sup 7} M {sub ⊙} and 0.03%–2.52%, respectively. We compare these results with those of other submillimeter-detected infrared luminous galaxies. The bump DOGs, the majority of the DOG sample, show similar distributions of dust temperatures and total dust mass to the comparison sample. The power-law DOGs show a hint of smaller dust masses than other samples, but need to be tested with a larger sample. These findings support that the reason DOGs show heavy dust obscuration is not an overall amount of dust content, but probably the spatial distribution of dust therein.« less
Airborne desert dust and aeromicrobiology over the Turkish Mediterranean coastline
Griffin, Dale W.; Kubilay, Nilgün; Kocak, Mustafa; Gray, Mike A.; Borden, Timothy C.; Shinn, Eugene A.
2007-01-01
Between 18 March and 27 October 2002, 220 air samples were collected on 209 of 224 calendar days, on top of a coastal atmospheric research tower in Erdemli, Turkey. The volume of air filtered for each sample was 340 liters. Two hundred fifty-seven bacterial and 2598 fungal colony forming units (CFU) were enumerated from the samples using a low-nutrient agar. Ground-based dust measurements demonstrated that the region is routinely impacted by dust generated regionally and from North Africa and that the highest combined percent recovery of total CFU and African dust deposition occurred in the month of April (93.4% of CFU recovery and 91.1% of dust deposition occurred during African dust days versus no African dust present, for that month). A statistically significant correlation was observed (peak regional African dust months of March, April and May; rs=0.576, P=0.000) between an increase in the prevalence of microorganisms recovered from atmospheric samples on dust days (regional and African as determined by ground-based dust measurements), versus that observed on non-dust days. Given the prevalence of atmospherically suspended desert dust and microorganisms observed in this study, and that culture-based studies typically only recover a small fraction (
Comparison of methods to control floor contamination in an animal research facility.
Allen, Kenneth P; Csida, Tarrant; Leming, Jeaninne; Murray, Kathleen; Gauld, Stephen B; Thulin, Joseph
2012-10-01
The authors evaluated the effectiveness of adhesive mats, contamination control flooring, and shoe covers in decreasing the presence of microbial agents on animal holding room floors and footwear. Swab samples taken from animal holding room floors after the use of each product were compared with samples taken from rooms after no products were used. Swab samples were also taken from the heels and soles of the footwear of animal care staff before and after use of each product. The use of contamination control flooring or shoe covers significantly reduced the amount of organic material (as indicated by ATP levels measured by a luminometer) present on floors. Bacterial and ATP contamination of footwear was significantly lower after the use of shoe covers than after the use of adhesive mats or contamination control flooring, and the use of shoe covers led to a greater decrease in contamination before and after use than did use of either of the other two products. Although shoe covers were superior to both adhesive mats and contamination control flooring for decreasing contamination of animal room floors and footwear, facilities must take into account the contamination control standards required, the cost of the product, and the labor and time associated with product use when deciding which contamination control practices to implement.
40 CFR 745.90 - Renovator certification and dust sampling technician certification.
Code of Federal Regulations, 2010 CFR
2010-07-01
... sampling technician certification. 745.90 Section 745.90 Protection of Environment ENVIRONMENTAL PROTECTION... RESIDENTIAL STRUCTURES Residential Property Renovation § 745.90 Renovator certification and dust sampling technician certification. (a) Renovator certification and dust sampling technician certification. (1) To...
MGS-TES thermal inertia study of the Arsia Mons Caldera
Cushing, G.E.; Titus, T.N.
2008-01-01
Temperatures of the Arsia Mons caldera floor and two nearby control areas were obtained by the Mars Global Surveyor (MGS) Thermal Emission Spectrometer (TES). These observations revealed that the Arsia Mons caldera floor exhibits thermal behavior different from the surrounding Tharsis region when compared with thermal models. Our technique compares modeled and observed data to determine best fit values of thermal inertia, layer depth, and albedo. Best fit modeled values are accurate in the two control regions, but those in the Arsia Mons' caldera are consistently either up to 15 K warmer than afternoon observations, or have albedo values that are more than two standard deviations higher than the observed mean. Models of both homogeneous and layered (such as dust over bedrock) cases were compared, with layered-cases indicating a surface layer at least thick enough to insulate itself from diurnal effects of an underlying substrate material. Because best fit models of the caldera floor poorly match observations, it is likely that the caldera floor experiences some physical process not incorporated into our thermal model. Even on Mars, Arsia Mons is an extreme environment where CO2 condenses upon the caldera floor every night, diurnal temperatures range each day by a factor of nearly 2, and annual average atmospheric pressure is only around one millibar. Here, we explore several possibilities that may explain the poor modeled fits to caldera floor and conclude that temperature dependent thermal conductivity may cause thermal inertia to vary diurnally, and this effect may be exaggerated by presence of water-ice clouds, which occur frequently above Arsia Mons. Copyright 2008 by the American Geophysical Union.
Ackerman, Seth D.; Pappal, Adrienne L.; Huntley, Emily C.; Blackwood, Dann S.; Schwab, William C.
2015-01-01
Sea-floor sample collection is an important component of a statewide cooperative mapping effort between the U.S. Geological Survey (USGS) and the Massachusetts Office of Coastal Zone Management (CZM). Sediment grab samples, bottom photographs, and video transects were collected within Vineyard Sound and Buzzards Bay in 2010 aboard the research vesselConnecticut. This report contains sample data and related information, including analyses of surficial-sediment grab samples, locations and images of sea-floor photography, survey lines along which sea-floor video was collected, and a classification of benthic biota observed in sea-floor photographs and based on the Coastal and Marine Ecological Classification Standard (CMECS). These sample data and analyses information are used to verify interpretations of geophysical data and are an essential part of geologic maps of the sea floor. These data also provide a valuable inventory of benthic habitat and resources. Geographic information system (GIS) data, maps, and interpretations, produced through the USGS and CZM mapping cooperative, are intended to aid efforts to manage coastal and marine resources and to provide baseline information for research focused on coastal evolution and environmental change.
[Free crystalline silica: a comparison of methods for its determination in total dust].
Maciejewska, Aleksandra; Szadkowska-Stańczyk, Irena; Kondratowicz, Grzegorz
2005-01-01
The major objective of the study was to compare and investigate the usefulness of quantitative analyses of free crystalline silica (FCS) in the assessment of dust exposure in samples of total dust of varied composition, using three methods: chemical method in common use in Poland; infrared spectrometry; and x-ray powder diffraction. Mineral composition and FCS contents were investigated in 9 laboratory samples of raw materials, materials, and industrial wastes, containing from about 2 to over 80% of crystalline silica and reduced to particles of size corresponding with that of total dust. Sample components were identified using XRD and FT-IR methods. Ten independent determinations of FCS with each of the three study methods were performed in dust samples. An analysis of linear correlation was applied to investigate interrelationship between mean FCS determinations. In analyzed dust samples, along with silica dust there were numerous minerals interfering with silica during the quantitative analysis. Comparison of mean results of FCS determinations showed that the results obtained using the FT-IR method were by 12-13% lower than those obtained with two other methods. However, the differences observed were within the limits of changeability of results associated with their precision and dependence on reference materials used. Assessment of occupational exposure to dusts containing crystalline silica can be performed on the basis of quantitative analysis of FCS in total dusts using each of the compared methods. The FT-IR method is most appropriate for the FCS determination in samples of small amount of silica or collected at low dust concentrations; the XRD method for the analysis of multicomponent samples; and the chemical method in the case of medium and high FCS contents in samples or high concentrations of dusts in the work environment.
Li, Yiwen; Liao, Ruoying; Gan, Zhiwei; Qu, Bing; Wang, Rong; Chen, Mengqin; Ding, Sanglan; Su, Shijun
2018-04-25
A total of 97 paired soil, outdoor dust, and indoor dust samples were collected in the national scale of China in summer, and the perchlorate levels were compared with those in soil and outdoor dust samples collected in winter in our previous study. The median perchlorate concentrations in the outdoor dust, indoor dust, and soil samples were 8.10, 11.4, and 0.05 mg/kg, respectively, which were significantly lower than those in the winter samples due to the natural factors and human activities. No significant differences in perchlorate concentrations were found between Northern and Southern China in the dust samples, whereas the difference was obtained in the soil samples. In the terms of possible source, the perchlorate levels in the outdoor dust exhibited strong correlation with SO 4 2- (r 2 = 0.458**) and NO 3 - (r 2 = 0.389**), indicating part of perchlorate in outdoor environment was likely from atmospheric oxidative process in summer. The perchlorate, SO 4 2- , and Cl - levels in the indoor dust were significantly related to those in the outdoor dust, suggesting that outdoor contaminants might be an important source for indoor environment. Furthermore, the human exposure to perchlorate was under relatively safe state in China except for special sites or periods with high perchlorate levels. Dust made an unexpected contribution of 41.3% to the total daily perchlorate intake for children, whereas 2.46% for adults in China based on biomonitoring, which deserves more attention.
PERFLUORINATED COMPOUNDS IN ARCHIVED HOUSE-DUST SAMPLES
Archived house-dust samples were analyzed for 13 perfluorinated compounds (PFCs). Results show that PFCs are found in house-dust samples, and the data are log-normally distributed. PFOS/PFOA were present in 94.6% and 96.4% of the samples respectively. Concentrations ranged fro...
RECOMMENDATIONS FOR SAMPLING OF TANK 18 IN F TANK FARM
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shine, G.
2009-12-14
Representative sampling is required for characterization of the residual floor material in Tank 18 prior to operational closure. Tank 18 is an 85-foot diameter, 34-foot high carbon steel tank with nominal operating volume of 1,300,000 gallons. It is a Type IV tank, and has been in service storing radioactive materials since 1959. Recent mechanical cleaning of the tank removed all mounds of material. Anticipating a low level of solids in the residual material, Huff and Thaxton [2009] developed a plan to sample the material during the final clean-up process while it would still be resident in sufficient quantities to supportmore » analytical determinations in four quadrants of the tank. Execution of the plan produced fewer solids than expected to support analytical determinations in all four quadrants. Huff and Thaxton [2009] then restructured the plan to characterize the residual floor material separately in the North and the South regions: two 'hemispheres.' This document provides sampling recommendations to complete the characterization of the residual material on the tank bottom following the guidance in Huff and Thaxton [2009] to split the tank floor into a North and a South hemisphere. The number of samples is determined from a modification of the formula previously published in Edwards [2001] and the sample characterization data for previous sampling of Tank 18 described by Oji [2009]. The uncertainty is quantified by an upper 95% confidence limit (UCL95%) on each analyte's mean concentration in Tank 18. The procedure computes the uncertainty in analyte concentration as a function of the number of samples, and the final number of samples is determined when the reduction in the uncertainty from an additional sample no longer has a practical impact on results. The characterization of the full suite of analytes in the North hemisphere is currently supported by a single Mantis rover sample obtained from a compact region near the center riser. A floor scrape sample was obtained from a compact region near the northeast riser and has been analyzed for a shortened list of key analytes. Since the unused portion of the floor scrape sample material is archived and available in sufficient quantity, additional analyses need to be performed to complete results for the full suite of constituents. The characterization of the full suite of analytes in the South hemisphere is currently supported by a single Mantis rover sample; there have been no floor scrape samples previously taken from the South hemisphere. The criterion to determine the number of additional samples was based on the practical reduction in the uncertainty when a new sample is added. This was achieved when five additional samples are obtained. In addition, two archived samples will be used if a contingency such as failing to demonstrate the comparability of the Mantis samples to the floor scrape samples occurs. To complete sampling of the Tank 18 residual floor material, three additional samples should be taken from the North hemisphere and four additional samples should be taken from the South hemisphere. One of the samples from each hemisphere will be archived in case of need. Two of the three additional samples from the North hemisphere and three of the four additional samples from the South hemisphere will be analyzed. Once the results are available, differences between the Mantis and three floor scrape samples (the sample previously obtained near NE riser plus the two additional samples that will be analyzed) results will be evaluated. If there are no statistically significant analyte concentration differences between the Mantis and floor scrape samples, those results will be combined and then UCL95%s will be calculated. If the analyte concentration differences between the Mantis and floor scrape samples are statistically significant, the UCL95%s will be calculated without the Mantis sample results. If further reduction in the upper confidence limits is needed and can be achieved by the addition of the archived samples, they will be analyzed and included in the statistical computations. Initially, the analyte concentrations in the residual material on the floor of Tank 18 will be determined separately in the North and the South hemispheres. However, if final sampling results show that differences between the North and South samples are consistent within sampling variation, then the final computations can be based on consolidating all sample results from the tank floor. Recommended locations may be subject to physical tank access and sampling constraints for the additional samples. The recommendations have been discussed in Section 4 and are based on partitioning the Tank 18 floor into an inner and an outer ring and six 60{sup o} sectors depicted in Figure 1. The location of the border between the inner and outer rings is based on dividing the residual material into two approximately equal volumes.« less
Comet 67p/Churyumov-Gerasimenko, possible origin of the depression Hatmehit
NASA Astrophysics Data System (ADS)
Kossacki, Konrad J.; Czechowski, Leszek
2018-05-01
On the nucleus of comet 67P/Churyumov-Gerasimenko numerous pits and depressions of different sizes are identified. In the present work the origin of depression Hatmehit is investigated. We propose a mechanism that includes recession of the surface due to sub-dust sublimation together with formation of cavities. Recession of the surface is calculated taking into account the sub-dust sublimation of water ice with volatile organic components, formation of a strengthened ice-dust crust due to sintering of ice grains and the increase of the gas pressure in pores due to release of gaseous CO. Our simulations indicate, that the formation of a 300 m deep depression due to the sub-dust sublimation of ice can take as little as 50 orbital periods assuming that the heliocentric distance at perihelion is close to its present value (Ip. et al., 2016). When amorphous water ice is present at small depth the release of gaseous CO may cause either compression of low-strength material beneath the strengthened crust, or ejection of the crust. In both cases a cavity is formed and grows due to the sublimation of ice from the wall and the floor.
Jafta, Nkosana; Batterman, Stuart A.; Gqaleni, Nceba; Naidoo, Rajen N.; Robins, Thomas G.
2012-01-01
The South Durban Health Study is a population-based study that examined the relationship between exposure to ambient air pollutants and respiratory disease among school children with high prevalence of asthma who resided in two purposely-selected communities in north and south Durban, KwaZulu-Natal, South Africa. From these participants, a subgroup of 135 families was selected for investigation of household characteristics potentially related to respiratory health. In these households, a walkthrough investigation was conducted, and settled dust and air samples were collected for allergen and fungal measurements using standardised techniques. Asp f1 allergen was detected in all homes, and Bla g1 allergen was detected in half of the homes. House dust allergens, Der f1 and Der p1 exceeded concentrations associated with risk of sensitization and exacerbation of asthma in 3 and 13%, respectively, of the sampled homes, while Bla g1 exceeded guidance values in 13% of the homes. Although airborne fungal concentrations in sleep areas and indoors were lower than outdoor concentrations, they exceeded 1000 CFU/m3 in 29% of the homes. Multivariate analyses identified several home characteristics that were predictors of airborne fungal concentrations, including moisture, ventilation, floor type and bedding type. Airborne fungal concentrations were similar indoors and outdoors, which likely reduced the significance of housing and indoor factors as determinants of indoor concentrations. Conclusion Allergen concentrations were highly variable in homes, and a portion of the variability can be attributed to easily-recognised conditions. PMID:22674665
Assessment of Workers’ Occupational Exposure in The Context of Industrial Toxicology
NASA Astrophysics Data System (ADS)
Călămar, Angelica; Găman, George Artur; Toth, Lorand; Pupăzan, Daniel; Simion, Sorin
2016-10-01
Knowledge and assessment of occupational risks in every workplace is the main objective of the prevention of occupational illnesses. The ultimate goal of safety and health at work is to protect life, integrity and health of workers against the risks of accidents and professional diseases that may occur in the workplace. This paper approaches the measurement of workplace respirable dust and microclimate parameters at a Romanian branch of a multinational company, in order to analyse the results in terms of safety and health of workers. The means of investigating the studied objective involved knowledge of the working environment, choice of pollutants, sampling, analysis and interpretation of sampled materials, as well as equipment and working methods. The research started as a result of an employee complaining about headache, respiratory discomfort and nasal congestion. The most frequent noxae measuring takes place in a working environment with developed industrial activities generating physical and chemical agents. This paper investigated the presence of noxae in workplaces located in Open Space offices where the main activity is IT. These spaces are ventilated by an air conditioning system, windows are fixed and the floor is carpeted on the entire surface. Research has led to the fact that the measured noxae (dusts, microclimate) have exceeded the maximum permissible concentration required by national legislation, this being an unexpected out coming for the company manager. These concentrations may be due to staff traffic, high number of employees and lack of natural ventilation. Following the evaluation results, a number of technical and organizational measures, aimed at improving the workplace atmosphere, was recommended.
STATISTICAL ANALYSIS OF TANK 18F FLOOR SAMPLE RESULTS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harris, S.
2010-09-02
Representative sampling has been completed for characterization of the residual material on the floor of Tank 18F as per the statistical sampling plan developed by Shine [1]. Samples from eight locations have been obtained from the tank floor and two of the samples were archived as a contingency. Six samples, referred to in this report as the current scrape samples, have been submitted to and analyzed by SRNL [2]. This report contains the statistical analysis of the floor sample analytical results to determine if further data are needed to reduce uncertainty. Included are comparisons with the prior Mantis samples resultsmore » [3] to determine if they can be pooled with the current scrape samples to estimate the upper 95% confidence limits (UCL{sub 95%}) for concentration. Statistical analysis revealed that the Mantis and current scrape sample results are not compatible. Therefore, the Mantis sample results were not used to support the quantification of analytes in the residual material. Significant spatial variability among the current sample results was not found. Constituent concentrations were similar between the North and South hemispheres as well as between the inner and outer regions of the tank floor. The current scrape sample results from all six samples fall within their 3-sigma limits. In view of the results from numerous statistical tests, the data were pooled from all six current scrape samples. As such, an adequate sample size was provided for quantification of the residual material on the floor of Tank 18F. The uncertainty is quantified in this report by an upper 95% confidence limit (UCL{sub 95%}) on each analyte concentration. The uncertainty in analyte concentration was calculated as a function of the number of samples, the average, and the standard deviation of the analytical results. The UCL{sub 95%} was based entirely on the six current scrape sample results (each averaged across three analytical determinations).« less
STATISTICAL ANALYSIS OF TANK 19F FLOOR SAMPLE RESULTS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harris, S.
2010-09-02
Representative sampling has been completed for characterization of the residual material on the floor of Tank 19F as per the statistical sampling plan developed by Harris and Shine. Samples from eight locations have been obtained from the tank floor and two of the samples were archived as a contingency. Six samples, referred to in this report as the current scrape samples, have been submitted to and analyzed by SRNL. This report contains the statistical analysis of the floor sample analytical results to determine if further data are needed to reduce uncertainty. Included are comparisons with the prior Mantis samples resultsmore » to determine if they can be pooled with the current scrape samples to estimate the upper 95% confidence limits (UCL95%) for concentration. Statistical analysis revealed that the Mantis and current scrape sample results are not compatible. Therefore, the Mantis sample results were not used to support the quantification of analytes in the residual material. Significant spatial variability among the current scrape sample results was not found. Constituent concentrations were similar between the North and South hemispheres as well as between the inner and outer regions of the tank floor. The current scrape sample results from all six samples fall within their 3-sigma limits. In view of the results from numerous statistical tests, the data were pooled from all six current scrape samples. As such, an adequate sample size was provided for quantification of the residual material on the floor of Tank 19F. The uncertainty is quantified in this report by an UCL95% on each analyte concentration. The uncertainty in analyte concentration was calculated as a function of the number of samples, the average, and the standard deviation of the analytical results. The UCL95% was based entirely on the six current scrape sample results (each averaged across three analytical determinations).« less
Mielke, Howard W; Gonzales, Christopher; Powell, Eric; Mielke, Paul W
2014-07-21
In 2012 the U.S. Centers for Disease Control (CDC) set the blood Pb reference value at ≥5 µg/dL. Clinical analysis of children's blood Pb levels is the common way to diagnose environmental Pb contamination, and intervention ensues with education and household dust cleanup. Recent review indicates that education and household dust cleanup are not effective at reducing children's Pb exposure. Here we review mapping environmental Pb and children's blood Pb response as an alternative approach for proactive Pb dust intervention. New Orleans was divided into a high (≥100 mg/kg) and low (<100 mg/kg) soil Pb communities. The children's blood Pb prevalence ≥5 µg/dL for the high and low Pb domains were 58.5% and 24.8% respectively pre-Katrina vs. 29.6% and 7.5% post-Katrina. Elevated soil Pb (mg/kg) and consequently Pb loading (µg/square area) permeates the high Pb domain and outdoor locations lack Pb dust safe play areas. The U.S. EPA 400 mg/kg soil Pb standard poses an outside Pb dust loading burden >37 times larger than allowed on interior residential floor environments. Environmental Pb dust is decreasing because of the transfer of large quantities of low Pb soil into selected communities. City-scale soil Pb mapping is an alternative diagnostic tool that provides information for planning proactive medicine to prevent clinical Pb exposure in the first place.
Mielke, Howard W.; Gonzales, Christopher; Powell, Eric; Mielke, Paul W.
2014-01-01
In 2012 the U.S. Centers for Disease Control (CDC) set the blood Pb reference value at ≥5 µg/dL. Clinical analysis of children’s blood Pb levels is the common way to diagnose environmental Pb contamination, and intervention ensues with education and household dust cleanup. Recent review indicates that education and household dust cleanup are not effective at reducing children’s Pb exposure. Here we review mapping environmental Pb and children’s blood Pb response as an alternative approach for proactive Pb dust intervention. New Orleans was divided into a high (≥100 mg/kg) and low (<100 mg/kg) soil Pb communities. The children’s blood Pb prevalence ≥5 µg/dL for the high and low Pb domains were 58.5% and 24.8% respectively pre-Katrina vs. 29.6% and 7.5% post-Katrina. Elevated soil Pb (mg/kg) and consequently Pb loading (µg/square area) permeates the high Pb domain and outdoor locations lack Pb dust safe play areas. The U.S. EPA 400 mg/kg soil Pb standard poses an outside Pb dust loading burden >37 times larger than allowed on interior residential floor environments. Environmental Pb dust is decreasing because of the transfer of large quantities of low Pb soil into selected communities. City-scale soil Pb mapping is an alternative diagnostic tool that provides information for planning proactive medicine to prevent clinical Pb exposure in the first place. PMID:25050655
Deposition Rates and Characterization of Arabian Mineral Dust
NASA Astrophysics Data System (ADS)
Puthan Purakkal, J.; Stenchikov, G. L.; Engelbrecht, J. P.
2015-12-01
Airborne mineral dust directly and indirectly impacts on global climate, continental and marine biochemistry, human and animal health, agriculture, equipment, and visibility. Annual global dust emissions are poorly known with estimates differing by a factor of at least two. Local dust emission and deposition rates are even less quantified. Dust deposition rate is a key parameter, which helps to constrain the modeled dust budget of the atmosphere. However, dust deposition remains poorly known, due to the limited number of reliable measurements. Simulations and satellite observations suggest that coastal dusts contribute substantially to the total deposition flux into the Red Sea. Starting December 2014, deposition samplers, both the "frisbee" type, and passive samplers for individual particle scanning electron microscopy were deployed at King Abdullah University of Science and Technology (KAUST), along the Red Sea in Saudi Arabia. Sampling periods of one month were adopted. The deposition rates range from 3 g m-2 month-1 for fair weather conditions to 23 g m-2 month-1 for high dust events. The X-ray diffraction (XRD) analyses of deposited dust samples show mineralogical compositions different from any of the parent soils, the former consisting mainly of gypsum, calcite, and smaller amounts of albite, montmorillonite, chlorite, quartz and biotite. The deposited dust samples on the other hand contain more gypsum and less quartz than the previously collected soil samples. This presentation discusses the results from XRD, chemical analysis and SEM-based individual particle analysis of the soils and the deposited dust samples. The monthly dust accumulation rates and their seasonal and spatial variability are compared with the regional model predictions. Data from this study provide an observational basis for validating the regional dust mass balance along the Arabian Red Sea coastal plain.
NASA Technical Reports Server (NTRS)
2004-01-01
3 February 2004 Wind is the chief agent of change on Mars today. Wind blows dust and it can move coarser sediment such as sand and silt. This Mars Global Surveyor (MGS) Mars Orbiter Camera (MOC) image shows bright ripples or small dunes on the floors of troughs northeast of Isidis Planitia near 31.1oN, 244.6oW. The picture covers an area 3 km (1.9 mi) wide; sunlight illuminates the scene from the lower left.
Assessment of exposure to oak wood dust using gallic acid as a chemical marker.
Carrieri, Mariella; Scapellato, Maria Luisa; Salamon, Fabiola; Gori, Giampaolo; Trevisan, Andrea; Bartolucci, Giovanni Battista
2016-01-01
The American Conference of Governmental Industrial Hygienists (ACGIH) has classified oak dust as a human carcinogen (A1), based on increased sinus and nasal cancer rates among exposed workers. The aims of this study were to investigate the use of gallic acid (GA) as a chemical marker of occupational exposure to oak dusts, to develop a high-performance liquid chromatography-diode array detector method to quantify GA and to apply the method in the analysis of oak dust samples collected in several factories. A high-performance liquid chromatography method was developed to detect GA in oak wood dust. The method was tested in the field, and GA was extracted from inhalable oak wood dust collected using the Institute of Occupational Medicine inhalable dust sampler in the air of five woodworking plants where only oak wood is used. A total of 57 samples with dust concentrations in the range of 0.27-11.14 mg/m(3) were collected. Five of these samples exceeded the Italian threshold limit value of 5 mg/m(3), and 30 samples exceeded the ACGIH TLV of 1 mg/m(3). The GA concentrations were in the range 0.02-4.18 µg/m(3). The total oak dust sampled was correlated with the GA content with a correlation coefficient (r) of 0.95. The GA in the tannic extracts of oak wood may be considered a good marker for this type of wood, and its concentration in wood dust sampled in the work environment is useful in assessing the true exposure to carcinogenic oak dust.
Taylor, C D; Reynolds, S J
2001-01-01
The production of livestock in enclosed facilities has become an accepted practice, driven by the need for increased efficiency. Exposure to organic dusts, containing various bioactive components, has been identified an important risk factor for the high rate of lung disease found among workers in these environments. Assessment of organic dust exposure requires technical skills and instrumentation not readily available to most agricultural enterprises. Development of a simple, cost-effective method for measuring organic dust levels would be useful in evaluating and controlling exposures in these environments. The objective of this study was to evaluate the usefulness of the direct reading MIE PDM-3 Miniram for estimating organic dust concentrations in enclosed swine production facilities. Responses from the MIE PDM-3 Miniram were compared to gravimetric methods for total and inhalable dust. Total dust determinations were conducted in accordance with the National Institute for Occupational Safety and Health (NIOSH) method 0500. Inhalable particulate mass (IPM) sampling was conducted using SKC brand IOM (Institute of Occupational Medicine) sampling cassettes, which meet the American Conference of Governmental Industrial Hygienists ACGIH criteria for inhalable dust sampling. This study design also allowed for the comparison of traditional total dust method to the IPM method, in collecting organic dusts in an agricultural setting. Fifteen sets of side-by-side samples (Miniram, total dust, and IPM) were collected over a period of six months in a swine confinement building. There were statistically significant differences in the results provided by the three sampling methods. Measurements for inhalable dust exceeded those for total dust in eleven of fifteen samples. The Miniram time-weighted average (TWA) response to the organic dust was always the lower of the three methods. A high degree of correlation was found among all three methods. The Miniram performed well under field conditions of varying temperature and humidity. The Miniram has the potential to predict the inhalable and total dust concentrations, assuming a correction factor for the organic dust being measured is applied.
NHEXAS PHASE I REGION 5 STUDY--METALS IN DUST ANALYTICAL RESULTS
This data set includes analytical results for measurements of metals in 1,906 dust samples. Dust samples were collected to assess potential residential sources of dermal and inhalation exposures and to examine relationships between analyte levels in dust and in personal and bioma...
In Situ Sampling of Terrestrial Dust Devils and Implications for Mars
NASA Astrophysics Data System (ADS)
Raack, J.; Reiss, D.; Balme, M. R.; Taj-Eddine, K.; Ori, G. G.
2017-09-01
We report on first very detailed in situ samples of the relative dust load and the vertical grain size distribution of terrestrial dust devils sampled during two field campaigns in Morocco and their implications for Mars. Our measurements imply, i.e., a similar internal structure for sampled dust devils, despite their different strenghts and dimensions; an exponential decreasing of particle size with height; and that between 60 and 70% of all lifted particles can go into atmospheric suspension.
Plumlee, Geoffrey S.; Hageman, Philip L.; Lamothe, Paul J.; Ziegler, Thomas L.; Meeker, Gregory P.; Theodorakos, Peter M.; Brownfield, Isabelle; Adams, Monique G.; Swayze, Gregg A.; Hoefen, Todd M.; Taggart, Joseph E.; Clark, Roger N.; Wilson, S.; Sutley, Stephen J.
2009-01-01
Samples of dust deposited around lower Manhattan by the September 11, 2001, World Trade Center (WTC) collapse have inorganic chemical compositions that result in part from the variable chemical contributions of concrete, gypsum wallboard, glass fibers, window glass, and other materials contained in the buildings. The dust deposits were also modified chemically by variable interactions with rain water or water used in street washing and fire fighting. Chemical leach tests using deionized water as the extraction fluid show the dust samples can be quite alkaline, due primarily to reactions with calcium hydroxide in concrete particles. Calcium and sulfate are the most soluble components in the dust, but many other elements are also readily leached, including metals such as Al, Sb, Mo Cr, Cu, and Zn. Indoor dust samples produce leachates with higher pH, alkalinity, and dissolved solids than outdoor dust samples, suggesting most outdoor dust had reacted with water and atmospheric carbon dioxide prior to sample collection. Leach tests using simulated lung fluids as the extracting fluid suggest that the dust might also be quite reactive in fluids lining the respiratory tract, resulting in dissolution of some particles and possible precipitation of new phases such as phosphates, carbonates, and silicates. Results of these chemical characterization studies can be used by health scientists as they continue to track and interpret health effects resulting from the short-term exposure to the initial dust cloud and the longer-term exposure to dusts resuspended during cleanup.
[Gohieria fusca found in dust of air-conditioner filters].
Qiang, Chai; Xiao-Dong, Zhan; Wei, Guo; Chao-Pin, Li
2017-09-25
To investigate the pollution status of Gohieria fusca in the air conditioner-filters of different places in Wuhu City. The dust samples were collected from the filters of air-conditioners in dining rooms, shopping malls, hotels and households between June and September, 2013, and G. fusca was detected in the dust samples. There were 430 dust samples collected and 98 were G. fusca positive with the breeding rate of 22.79%. The difference of breeding rates of G. fusca were statistically significant among the different places ( χ 2 =18.294, P < 0.05). Among 510.5 g dust samples in total, 783 G. fusca mites were detected with an average breeding density of 1.53 mite/g. G. fusca breeds in the dust of air-conditioner filters in Wuhu City gravely.
Carpeting in hospitals: an epidemiological evaluation.
Anderson, R L; Mackel, D C; Stoler, B S; Mallison, G F
1982-01-01
Epidemiological and microbiological studies were conducted in a hospital room with carpet (CR) and in one with carpet (NCR). Microbiological profiles were determined with specimens obtained from patients admitted to these rooms. Patient records were reviewed to note infection status and other case identities. Eleven-millimeter cylindrical core samples of carpet were obtained, and swab template techniques were used on the bare floor for subsequent enumeration and identification of contaminating microorganisms. In each sampling period, higher microbial counts per square inch (1 in(2) = ca 6.452 cm(2)) were measured for the carpet than for the bare floor. Recovery rates of Enterobacter spp., Klebsiella pneumoniae, and Escherichia coli were higher from carpet samples than from bare floor samples. Typable organisms (such as E. coli, Pseudomonas aeruginosa, K. pneumoniae, and Staphylococcus aureus) obtained from patients were also more frequently recovered from the carpet than from the bare flooring. Patients who stayed in the CR were shown to be colonized with the same types of organisms as those initially recovered from the carpet. However, no statistically significant differences were found in patients in the CR versus NCR in colonization with all typable and nontypable organisms first found on the floor. Disease in patients was found not to be associated with organisms found as contaminants of the carpet or the bare floor. Air above carpeting contained more consistent concentrations of organisms than air above the bare flooring. PMID:7076814
Wet Dust Deposition Across Texas, USA
NASA Astrophysics Data System (ADS)
Collins, J. D., Jr.; Ponette-González, A.; Gill, T. E.; Glass, G. A.; Weathers, K. C.
2016-12-01
Atmospheric dust deposition is of critical importance in terrestrial biogeochemical cycles, supplying essential limiting nutrients, such as calcium and phosphorus as well as pollutants, such as lead, to ecosystems. Dust particles are delivered to terrestrial ecosystems directly as dry deposition or in precipitation (wet deposition) as a result of rainout (particles incorporated into cloud droplets) and washout (particles that collide with raindrops as they fall). Compared to dry deposition, wet dust deposition (dissolved + particulate) is a poorly understood yet potentially significant pathway for dust input, especially in humid regions. We quantified wet dust deposition to two National Atmospheric Deposition Monitoring (NADP) sites across Texas-one in west (Guadalupe Mountains) and one in east (near Houston) Texas-with contrasting climate/dust regimes and land cover. We focused on 2012 during one of the most severe droughts in Texas since 1895. Dust event days (DEDs) were identified using meteorological data for stations within 150 km of the NADP sites where wet deposition was sampled weekly. DEDs were defined using the following criteria: visibility <10 km, <30% relative humidity, and wind speed >50 km, supplemented with other Saharan dust incursion and dust observations. A total of 34 DEDs (20 sample weeks) were identified for the west and 5 DEDs (4 sample weeks) for the east Texas sites. Bulk elemental composition of washout particles is analyzed using Particle Induced X-ray Emission (PIXE) spectroscopy and X-ray Fluorescence (XRF) spectroscopy. Using these data, we will examine differences in the chemical composition of rainwater and aerosol particles filtered from rain samples for dust versus non-dust event days at each study site. Deposition fluxes for dust and non-dust event weeks are also compared. Quantifying the magnitude of wet dust deposition is necessary to improve evaluation of dust impacts on biogeochemical cycles.
NASA Astrophysics Data System (ADS)
De Vis, P.; Gomez, H. L.; Schofield, S. P.; Maddox, S.; Dunne, L.; Baes, M.; Cigan, P.; Clark, C. J. R.; Gomez, E. L.; Lara-López, M.; Owers, M.
2017-10-01
We combine samples of nearby galaxies with Herschel photometry selected on their dust, metal, H I and stellar mass content, and compare these to chemical evolution models in order to discriminate between different dust sources. In a companion paper, we used an H I-selected sample of nearby galaxies to reveal a subsample of very gas-rich (gas fraction >80 per cent) sources with dust masses significantly below predictions from simple chemical evolution models, and well below Md/M* and Md/Mgas scaling relations seen in dust and stellar-selected samples of local galaxies. We use a chemical evolution model to explain these dust-poor, but gas-rich, sources as well as the observed star formation rates (SFRs) and dust-to-gas ratios. We find that (I) a delayed star formation history is required to model the observed SFRs; (II) inflows and outflows are required to model the observed metallicities at low gas fractions; (III) a reduced contribution of dust from supernovae (SNe) is needed to explain the dust-poor sources with high gas fractions. These dust-poor, low stellar mass galaxies require a typical core-collapse SN to produce 0.01-0.16 M⊙ of dust. To match the observed dust masses at lower gas fractions, significant grain growth is required to counteract the reduced contribution from dust in SNe and dust destruction from SN shocks. These findings are statistically robust, though due to intrinsic scatter it is not always possible to find one single model that successfully describes all the data. We also show that the dust-to-metal ratio decreases towards lower metallicity.
Wang, Liulin; Hou, Meiling; An, Jing; Zhong, Yufang; Wang, Xuetong; Wang, Yangjun; Wu, Minghong; Bi, Xinhui; Sheng, Guoying; Fu, Jiamo
2011-10-01
Electrical and electronic waste (E-waste) has now become the fastest growing solid waste around the world. Primitive recycling operations for E-waste have resulted in severe contamination of toxic metals and organic chemicals in the related areas. In this study, six dust and soil samples collected from E-waste recycling workshops and open-burning sites in Longtang were analyzed to investigate their cytotoxicity and genotoxicity on L02 cells. These six samples were: dust No. 1 collected at the gate of the workshop; dust No. 2 collected from air conditioning compressor dismantling site; dust No. 3 collected from where some motors, wires, and aluminium products since the 1980s were dismantled; soil No. 1 collected at the circuit board acid washing site; soil No. 2 collected from a wire open-burning site; soil No. 3 collected near a fiber open-burning site. At the same time, two control soil samples were collected from farmlands approximately 8 km away from the dismantling workshops. The results showed that all of these samples could inhibit cell proliferation and cause cell membrane lesion, among which dust No. 3 and soil No. 2 had the strongest toxicity. Moreover, the comet assay showed that the dust No. 3 had the most significant capability to cause DNA single-strand beaks (SSB), while the road dust (dust No. 1) collected at the gate of the workshop, a relatively farer site, showed the slightest capability to induce DNA SSB. The intracellular reactive oxygen species (ROS) detection showed that ROS level was elevated with the increase of dust and soil samples concentration. Dust No. 3 and soil No. 2 had the highest ROS level, followed by dust No. 2 and 1, soil No. 3 and 1. All of the above results indicated that polluted soil and dust from the E-waste area had cytotoxicity and genotoxicity on L02 cells, the mechanism might involve the increased ROS level and consequent DNA SSB.
Airborne desert dust and aeromicrobiology over the Turkish Mediterranean coastline
NASA Astrophysics Data System (ADS)
Griffin, Dale W.; Kubilay, Nilgün; Koçak, Mustafa; Gray, Mike A.; Borden, Timothy C.; Shinn, Eugene A.
Between 18 March and 27 October 2002, 220 air samples were collected on 209 of 224 calendar days, on top of a coastal atmospheric research tower in Erdemli, Turkey. The volume of air filtered for each sample was 340 liters. Two hundred fifty-seven bacterial and 2598 fungal colony forming units (CFU) were enumerated from the samples using a low-nutrient agar. Ground-based dust measurements demonstrated that the region is routinely impacted by dust generated regionally and from North Africa and that the highest combined percent recovery of total CFU and African dust deposition occurred in the month of April (93.4% of CFU recovery and 91.1% of dust deposition occurred during African dust days versus no African dust present, for that month). A statistically significant correlation was observed (peak regional African dust months of March, April and May; rs=0.576, P=0.000) between an increase in the prevalence of microorganisms recovered from atmospheric samples on dust days (regional and African as determined by ground-based dust measurements), versus that observed on non-dust days. Given the prevalence of atmospherically suspended desert dust and microorganisms observed in this study, and that culture-based studies typically only recover a small fraction (<1.0%) of the actual microbial population in any given environment, dust-borne microorganisms and other associated constituents (organic detritus, toxins, etc.) may play a significant role in the regional human and ecosystem health.
78 FR 25308 - Proposed Collection; Comment Request; Coal Mine Dust Sampling Devices
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-30
...; Coal Mine Dust Sampling Devices AGENCY: Mine Safety and Health Administration, Labor. ACTION: 60-Day.... Background Continuous Personal Dust Monitors (CPDMs) determine the concentration of respirable dust in coal mines. CPDMs must be designed and constructed for coal miners to wear and operate without impeding their...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-19
...The Mine Safety and Health Administration (MSHA) proposes to lower miners' exposure to respirable coal mine dust by revising the Agency's existing standards on miners' occupational exposure to respirable coal mine dust. The major provisions of the proposal would lower the existing exposure limit; provide for full-shift sampling; redefine the term ``normal production shift; '' and add reexamination and decertification requirements for persons certified to sample, and maintain and calibrate sampling devices. In addition, the proposed rule would provide for single shift compliance sampling under the mine operator and MSHA's inspector sampling programs, and would establish sampling requirements for use of the Continuous Personal Dust Monitor (CPDM) and expanded requirements for medical surveillance. The proposed rule would significantly improve health protections for this Nation's coal miners by reducing their occupational exposure to respirable coal mine dust and lowering the risk that they will suffer material impairment of health or functional capacity over their working lives.
A survey of spatially distributed exterior dust lead loadings in New York City
DOE Office of Scientific and Technical Information (OSTI.GOV)
Caravanos, Jack; Weiss, Arlene L.; School of Medicine, New York University, NY 10016
This work documents ambient lead dust deposition values (lead loading) for the boroughs of New York City in 2003-2004. Currently, no regulatory standards exist for exterior concentrations of lead in settled dust. This is in contrast to the clearance and risk assessment standards that exist for interior residential dust. The reported potential for neurobehavioral toxicity and adverse cognitive development in children due to lead exposure prompts public health concerns about undocumented lead sources. Such sources may include settled dust of outdoor origin. Dust sampling throughout the five boroughs of NYC was done from the top horizontal portion of pedestrian trafficmore » control signals (PTCS) at selected street intersections along main thoroughfares. The data (n=214 samples) show that lead in dust varies within each borough with Brooklyn having the highest median concentration (730{mu}g/ft{sup 2}), followed in descending order by Staten Island (452{mu}g/ft{sup 2}), the Bronx (382{mu}g/ft{sup 2}), Queens (198{mu}g/ft{sup 2}) and finally, Manhattan (175{mu}g/ft{sup 2}). When compared to the HUD/EPA indoor lead in dust standard of 40{mu}g/ft{sup 2}, our data show that this value is exceeded in 86% of the samples taken. An effort was made to determine the source of the lead in the dust atop of the PTCS. The lead in the dust and the yellow signage paint (which contains lead) were compared using isotopic ratio analysis. Results showed that the lead-based paint chip samples from intact signage did not isotopically match the dust wipe samples taken from the same surface. We know that exterior dust containing lead contributes to interior dust lead loading. Therefore, settled leaded dust in the outdoor environment poses a risk for lead exposure to children living in urban areas, namely, areas with elevated childhood blood lead levels and background lead dust levels from a variety of unidentified sources.« less
NASA Astrophysics Data System (ADS)
Goodman, M.; Carling, G. T.; Fernandez, D. P.; Rey, K.; Hale, C. A.; Nelson, S.; Hahnenberger, M.
2017-12-01
Desert playas are important dust sources globally, with potential harmful health impacts for nearby urban areas. The Wasatch Front (population >2 million) in western Utah, USA, is located directly downwind of several playas that contribute to poor air quality on dust event days. Additionally, the exposed lakebed of nearby Great Salt Lake is a growing dust source as water levels drop in response to drought and river diversions. To investigate contributions of playa dust to the Wasatch Front, we sampled dust emissions from the exposed lakebed of Great Salt Lake and seven playas in western Utah, including Sevier Dry Lake, and dust deposition at four locations stretching 160 km from south to north along the Wasatch Front, including Provo, Salt Lake City, Ogden, and Logan. The samples were analyzed for mineralogy, bulk chemistry, and 87Sr/86Sr ratios for source apportionment. The mineralogy of playa dust and Wasatch Front dust samples was dominated by quartz, feldspar, chlorite and calcite. Bulk geochemical composition was similar for all playa dust sources, with higher anthropogenic metal concentrations in the Wasatch Front. Strontium isotope (87Sr/86Sr) ratios in the carbonate fraction of the dust samples were variable in the playa dust sources, ranging from 0.7105 in Sevier Dry Lake to 0.7150 in Great Salt Lake, providing a powerful tool for apportioning dust. Based on 87Sr/86Sr mixing models, Great Salt Lake contributed 0% of the dust flux at Provo, 20% of the dust flux at Salt Lake City, and 40% of the dust flux at Ogden and Logan during Fall 2015. Contrastingly, Great Salt Lake dust was less important in Spring of 2016, contributing 0% of the dust flux at Provo and <10% of the dust flux to Salt Lake City and Logan. Two major dust events that occurred on 3 November 2015 and 23 April 2016 had similar wind and climate conditions as understood by HYSPLIT backward trajectories, meaning that seasonal variability in dust emissions is due to playa surface conditions rather than meteorologic conditions. Further sampling and analysis are needed to understand and quantify patterns in seasonal changes in dust emissions and deposition. These findings suggest that 87Sr/86Sr ratios of the carbonate fraction in dust may be useful for evaluating dust emissions from carbonate-rich playas around the world.
Wang, W; Erf, G F; Wideman, R F
2002-11-01
Intravenous endotoxin has been shown to trigger a delayed pulmonary hypertensive response that varies widely in magnitude and duration among individual broilers. It was proposed that this individual variability may reflect immunological differences acquired during previous respiratory challenges that might have subsequently altered the endotoxin-initiated biochemical cascade. In Experiment 1, we tested the hypothesis that, when compared with broilers reared in clean stainless steel cages (Cage group), broilers reared on floor litter (Floor group) should experience a greater respiratory challenge and therefore may consistently exhibit a more enhanced pulmonary hypertensive response to intravenous endotoxin. Birds in the Cage group were grown in stainless steel cages at a low density (72 birds/8 m2 chamber), and fecal and dander materials were removed daily. Birds in the Floor group were reared on wood-shavings litter at a higher density (110 birds/8 m2 chamber). Pulmonary and systemic mean arterial pressures and blood-gas values were evaluated prior to and following the intravenous administration of 1 mg Salmonella typhimurium endotoxin. Broilers in the Floor and Cage groups exhibited pulmonary hypertensive responses to endotoxin that were very similar in terms of time of onset, duration, and magnitude, as well as variability in the response among individuals. Systemic hypotension also developed similarly in both groups following endotoxin injection. Blood-gas values indicated that the partial pressure of CO2 and the HCO3- concentration in arterial blood were higher (P < 0.05) in the Floor group than in the Cage group prior to and subsequent to the endotoxin injection. In Experiment 2, we reevaluated the effect of a dirty vs. a clean environment on blood-gas values using a different strain of broilers, and confirmed the negative impact of floor rearing on blood-gas values. We conclude that broilers reared on the floor inhaled litter dust and noxious fumes, which impaired pulmonary gas exchange and increased the arterial partial pressure of CO2 when compared with broilers reared in clean stainless steel cages. Nevertheless, the pulmonary hypertensive response to endotoxin did not differ between broilers reared on the floor and those in cages.
75 FR 17511 - Coal Mine Dust Sampling Devices
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-06
... Part III Department of Labor Mine Safety and Health Adminisration 30 CFR Parts 18, 74, and 75 Coal Mine Dust Sampling Devices; High-Voltage Continuous Mining Machine Standard for Underground Coal Mines...-AB61 Coal Mine Dust Sampling Devices AGENCY: Mine Safety and Health Administration, Labor. ACTION...
Extraction of Thermal Performance Values from Samples in the Lunar Dust Adhesion Bell Jar
NASA Technical Reports Server (NTRS)
Gaier, James R.; Siamidis, John; Larkin, Elizabeth M. G.
2008-01-01
A simulation chamber has been developed to test the performance of thermal control surfaces under dusty lunar conditions. The lunar dust adhesion bell jar (LDAB) is a diffusion pumped vacuum chamber (10(exp -8) Torr) built to test material samples less than about 7 cm in diameter. The LDAB has the following lunar dust simulant processing capabilities: heating and cooling while stirring in order to degas and remove adsorbed water; RF air-plasma for activating the dust and for organic contaminant removal; RF H/He-plasma to simulate solar wind; dust sieving system for controlling particle sizes; and a controlled means of introducing the activated dust to the samples under study. The LDAB is also fitted with an in situ Xe arc lamp solar simulator, and a cold box that can reach 30 K. Samples of thermal control surfaces (2.5 cm diameter) are introduced into the chamber for calorimetric evaluation using thermocouple instrumentation. The object of this paper is to present a thermal model of the samples under test conditions and to outline the procedure to extract the absorptance, emittance, and thermal efficiency from the pristine and sub-monolayer dust covered samples.
Extraction of Thermal Performance Values from Samples in the Lunar Dust Adhesion Bell Jar
NASA Technical Reports Server (NTRS)
Gaier, James R.; Siamidis, John; Larkin, Elizabeth M.G.
2008-01-01
A simulation chamber has been developed to test the performance of thermal control surfaces under dusty lunar conditions. The lunar dust adhesion bell jar (LDAB) is a diffusion pumped vacuum chamber (10-8 Torr) built to test material samples less than about 7 cm in diameter. The LDAB has the following lunar dust stimulant processing capabilities: heating and cooling while stirring in order to degas and remove absorbed water; RF air-plasma for activating the dust and for organic contaminant removal; RF H/He-plasma to simulate solar wind; dust sieving system for controlling particle sizes; and a controlled means of introducing the activated dust to the samples under study. The LDAB is also fitted with an in situ Xe arc lamp solar simulator, and a cold box that can reach 30 K. Samples of thermal control surfaces (2.5 cm diameter) are introduced into the chamber for calorimetric evaluation using thermocouple instrumentation. The object of this paper is to present a thermal model of the samples under test conditions, and to outline the procedure to extract the absorptance, emittance, and thermal efficiency from the pristine and sub-monolayer dust covered samples
Extraction of Thermal Performance Values from Samples in the Lunar Dust Adhesion Bell Jar
NASA Technical Reports Server (NTRS)
Gaier, James R.; Siamidis, John; Larkin, Elizabeth M. G.
2010-01-01
A simulation chamber has been developed to test the performance of thermal control surfaces under dusty lunar conditions. The lunar dust adhesion bell jar (LDAB) is a diffusion pumped vacuum chamber (10(exp -8) Torr) built to test material samples less than about 7 cm in diameter. The LDAB has the following lunar dust simulant processing capabilities: heating and cooling while stirring in order to degas and remove adsorbed water; RF air-plasma for activating the dust and for organic contaminant removal; RF H/He-plasma to simulate solar wind; dust sieving system for controlling particle sizes; and a controlled means of introducing the activated dust to the samples under study. The LDAB is also fitted with an in situ Xe arc lamp solar simulator, and a cold box that can reach 30 K. Samples of thermal control surfaces (2.5 cm diameter) are introduced into the chamber for calorimetric evaluation using thermocouple instrumentation. The object of this paper is to present a thermal model of the samples under test conditions and to outline the procedure to extract the absorptance, emittance, and thermal efficiency from the pristine and sub-monolayer dust covered samples.
Chuvochina, Maria S; Marie, Dominique; Chevaillier, Servanne; Petit, Jean-Robert; Normand, Philippe; Alekhina, Irina A; Bulat, Sergey A
2011-01-01
Microorganisms uplifted during dust storms survive long-range transport in the atmosphere and could colonize high-altitude snow. Bacterial communities in alpine snow on a Mont Blanc glacier, associated with four depositions of Saharan dust during the period 2006-2009, were studied using 16S rRNA gene sequencing and flow cytometry. Also, sand from the Tunisian Sahara, Saharan dust collected in Grenoble and Mont Blanc snow containing no Saharan dust (one sample of each) were analyzed. The bacterial community composition varied significantly in snow containing four dust depositions over a 3-year period. Out of 61 phylotypes recovered from dusty snow, only three phylotypes were detected in more than one sample. Overall, 15 phylotypes were recognized as potential snow colonizers. For snow samples, these phylotypes belonged to Actinobacteria, Proteobacteria and Cyanobacteria, while for Saharan sand/dust samples they belonged to Actinobacteria, Bacteroidetes, Deinococcus-Thermus and Proteobacteria. Thus, regardless of the time-scale, Saharan dust events can bring different microbiota with no common species set to alpine glaciers. This seems to be defined more by event peculiarities and aeolian transport conditions than by the bacterial load from the original dust source.
NASA Astrophysics Data System (ADS)
Moores, John E.; Lemmon, Mark T.; Kahanpää, Henrik; Rafkin, Scot C. R.; Francis, Raymond; Pla-Garcia, Jorge; Bean, Keri; Haberle, Robert; Newman, Claire; Mischna, Michael; Vasavada, Ashwin R.; de la Torre Juárez, Manuel; Rennó, Nilton; Bell, Jim; Calef, Fred; Cantor, Bruce; Mcconnochie, Timothy H.; Harri, Ari-Matti; Genzer, Maria; Wong, Michael H.; Smith, Michael D.; Martín-Torres, F. Javier; Zorzano, María-Paz; Kemppinen, Osku; McCullough, Emily
2015-03-01
The Navigation Cameras (Navcam) of the Mars Science Laboratory rover, Curiosity, have been used to examine two aspects of the planetary boundary layer: vertical dust distribution and dust devil frequency. The vertical distribution of dust may be obtained by using observations of the distant crater rim to derive a line-of-sight optical depth within Gale Crater and comparing this optical depth to column optical depths obtained using Mastcam observations of the solar disc. The line of sight method consistently produces lower extinctions within the crater compared to the bulk atmosphere. This suggests a relatively stable atmosphere in which dust may settle out leaving the air within the crater clearer than air above and explains the correlation in observed column opacity between the floor of Gale Crater and the higher elevation Meridiani Planum. In the case of dust devils, despite an extensive campaign only one optically thick vortex (τ = 1.5 ± 0.5 × 10-3) was observed compared to 149 pressure events >0.5 Pa observed in REMS pressure data. Correcting for temporal coverage by REMS and geographic coverage by Navcam still suggests 104 vortices should have been viewable, suggesting that most vortices are dustless. Additionally, the most intense pressure excursions observed on other landing sites (pressure drop >2.5 Pa) are lacking from the observations by the REMS instrument. Taken together, these observations are consistent with pre-landing circulation modeling of the crater showing a suppressed, shallow boundary layer. They are further consistent with geological observations of dust that suggests the northern portion of the crater is a sink for dust in the current era.
Degradation of radiator performance on Mars due to dust
NASA Technical Reports Server (NTRS)
Gaier, James R.; Perez-Davis, Marla E.; Rutledge, Sharon K.; Forkapa, Mark
1992-01-01
An artificial mineral of the approximate elemental composition of Martian soil was manufactured, crushed, and sorted into four different size ranges. Dust particles from three of these size ranges were applied to arc-textured Nb-1 percent Zr and Cu radiator surfaces to assess their effect on radiator performance. Particles larger than 75 microns did not have sufficient adhesive forces to adhere to the samples at angles greater than about 27 deg. Pre-deposited dust layers were largely removed by clear wind velocities greater than 40 m/s, or by dust-laden wind velocities as low as 25 m/s. Smaller dust grains were more difficult to remove. Abrasion was found to be significant only in high velocity winds (89 m/s or greater). Dust-laden winds were found to be more abrasive than clear wind. Initially dusted samples abraded less than initially clear samples in dust laden wind. Smaller dust particles of the simulant proved to be more abrasive than large. This probably indicates that the larger particles were in fact agglomerates.
Using an Instrumented Drone to Sample Dust Devils
NASA Astrophysics Data System (ADS)
Jackson, Brian; Lorenz, Ralph; Davis, Karan; Lipple, Brock
2017-10-01
Dust devils are low-pressure, small (many to tens of meters) convective vortices powered by surface heating and rendered visible by lofted dust. Dust devils occur in arid climates on Earth, where they degrade air quality and pose a hazard to small aircraft. They also occur ubiquitously on Mars, where they may dominate the supply of atmospheric dust. Since dust contributes significantly to Mars’ atmospheric heat budget, dust devils probably play an important role in its climate. The dust-lifting capacity of a devil likely depends sensitively on its structure, particularly the wind and pressure profiles, but the exact dependencies are poorly constrained. Thus, the exact contribution to Mars’ atmosphere remains unresolved. Moreover, most previous studies of martian dust devils have relied on passive sampling of the profiles via meteorology packages on landed spacecraft, resulting in random encounter geometries which non-trivially skew the retrieved profiles. Analog studies of terrestrial devils have employed more active sampling (instrumented vehicles or manned aircraft) but have been limited to near-surface (few meters) or relatively high altitude (hundreds of meters) sampling. Unmanned aerial vehicles (UAVs) or drones, combined with miniature, digital instrumentation, promise a novel and uniquely powerful platform from which to sample dust devils via (relatively) controlled geometries at a wide variety of altitudes. In this presentation, we will describe a pilot study using an instrumented quadcopter on an active field site in southeastern Oregon, which (to our knowledge) has not previously been surveyed for dust devils. We will present preliminary results from the resulting encounters, including stereo image analysis and encounter footage collected onboard the drone.
Biogenic lipids in particulates from the lower atmosphere over the eastern Atlantic
NASA Technical Reports Server (NTRS)
Simoneit, B. R. T.; Chester, R.; Eglinton, G.
1977-01-01
The occurrence, isolation, and characterization of terrigenous lipids in aeolian dusts from the eastern Atlantic are discussed. It is pointed out that such lipids have also been found in aeolian dust from other oceanic areas. A description is presented of the collection and extraction of samples. The dust samples were extracted with two aliquots of toluene and methanol (3:1) for lipid analysis. The extracts were concentrated on a rotary evaporator. General aeolian dust collection data and sample descriptions are presented in a table. The origin of the samples is discussed.
PVC--as flooring material--and its association with incident asthma in a Swedish child cohort study.
Larsson, M; Hägerhed-Engman, L; Kolarik, B; James, P; Lundin, F; Janson, S; Sundell, J; Bornehag, C G
2010-12-01
The Dampness in Buildings and Health study (DBH) started in the year 2000 in Värmland, Sweden, with a baseline questionnaire sent to all children (n = 14,077) aged 1-6. Five years later, a follow-up questionnaire was sent to the children who were 1-3 years at baseline. A total of 4779 children participated in both the baseline and the follow-up studies and constitute the study population in this cohort study. The aim of this study was to examine the association between exposure to PVC-flooring in the child's and parent's bedroom in homes of children aged 1-3 and the incidence of asthma, rhinitis, and eczema during the following 5-year period. Adjusted analyses showed that the incidence of asthma among children was associated with PVC-flooring in the child's bedroom (AOR 1.52; 95% CI 0.99-2.35) and in the parent's bedroom (1.46; 0.96-2.23). The found risks were on borderline of significance and should therefore be interpreted with caution. There was further a positive relationship between the number of rooms with PVC-flooring and the cumulative incidence of asthma. PVC-flooring was found to be a stronger risk factor for incident asthma in multifamily homes when compared with single-family houses and in smoking families compared with non-smoking families and in women. These longitudinal data from the DBH study found an association between the presence of PVC-flooring in the home and incident asthma in children. However, earlier results from the DBH study have shown that PVC-flooring is one important source for phthalates in indoor dust, and exposure to such phthalates was found to be associated with asthma and allergy among children. This emphasizes the need for prospective studies that focus on the importance of prenatal and neonatal exposure to phthalates in the development of asthma and allergy in children. © 2010 John Wiley & Sons A/S.
Exum, Natalie G; Olórtegui, Maribel Paredes; Yori, Pablo Peñataro; Davis, Meghan F; Heaney, Christopher D; Kosek, Margaret; Schwab, Kellogg J
2016-07-19
Over two billion people worldwide lack access to an improved sanitation facility that adequately retains or treats feces. This results in the potential for fecal material containing enteric pathogens to contaminate the environment, including household floors. This study aimed to assess how floor type and sanitation practices impacted the concentration of fecal contamination on household floors. We sampled 189 floor surfaces within 63 households in a peri-urban community in Iquitos, Peru. All samples were analyzed for colony forming units (CFUs) of E. coli, and households were evaluated for their water, sanitation, and hygiene characteristics. Results of multivariate linear regression indicated that households with improved sanitation and cement floors in the kitchen area had reduced fecal contamination to those with unimproved sanitation and dirt floors (Beta: -1.18 log10 E. coli CFU/900 cm(2); 95% confidence interval [CI]: -1.77, -0.60). Households that did not versus did share their sanitation facility also had less contaminated kitchen floors (Beta: -0.65 log10 E. coli CFU/900 cm(2); 95% CI: -1.15, -0.16). These findings suggest that the sanitation facilities of a home may impact the microbial load found on floors, contributing to the potential for household floors to serve as an indirect route of fecal pathogen transmission to children.
Assessing airborne aflatoxin B1 during on-farm grain handling activities.
Selim, M I; Juchems, A M; Popendorf, W
1998-04-01
The presence of aflatoxin in corn and corn dust during relatively normal years and the increased risk of Aspergillus flavus infestation during drought conditions suggest that airborne agricultural exposures should be of considerable concern. Liquid extraction, thin layer chromatography, and high pressure liquid chromatography were used for the analysis of aflatoxin B1 in grain dust and bulk corn samples. A total of 24 samples of airborne dust were collected from 8 farms during harvest, 22 samples from 9 farms during animal feeding, and 14 sets of Andersen samples from 11 farms during bin cleaning. A total of 14 samples of settled dust and 18 samples of bulk corn were also collected and analyzed. The airborne concentration of aflatoxin B1 found in dust collected during harvest and grain unloading ranged from 0.04 to 92 ng/m3. Higher levels of aflatoxin B1 were found in the airborne dust samples collected from enclosed animal feeding buildings (5-421 ng/m3) and during bin cleaning (124-4849 ng/m3). Aflatoxin B1 up to 5100 ng/g were detected in settled dust collected from an enclosed animal feeding building; however, no apparent correlation was found between the airborne concentration of aflatoxin B1 and its concentration in settled dust or bulk corn. The data demonstrate that farmers and farm workers may be exposed to potentially hazardous concentrations of aflatoxin B1, particularly during bin cleaning and animal feeding in enclosed buildings.
Spectroscopic and x-ray diffraction analyses of asbestos in the World Trade Center dust:
Swayze, Gregg A.; Clark, Roger N.; Sutley, Stephen J.; Hoefen, Todd M.; Plumlee, Geoffrey S.; Meeker, Gregory P.; Brownfield, Isabelle; Livo, Keith E.; Morath, Laurie C.
2009-01-01
On September 17 and 18, 2001, samples of settled dust and airfall debris were collected from 34 sites within a 1-km radius of the WTC collapse site, including a sample from an indoor location unaffected by rainfall, and samples of insulation from two steel beams at Ground Zero. Laboratory spectral and x-ray diffraction analyses of the field samples detected trace levels of serpentine minerals, including chrysotile asbestos, in about two-thirds of the dust samples at concentrations at or below ~1 wt%. One sample of a beam coating material contained up to 20 wt% chrysotile asbestos. Analyses indicate that trace levels of chrysotile were distributed with the dust radially to distances greater than 0.75 km from Ground Zero. The chrysotile content of the dust is variable and may indicate that chrysotile asbestos was not distributed uniformly during the three collapse events.
Estimation of respirable dust exposure among coal miners in South Africa.
Naidoo, Rajen; Seixas, Noah; Robins, Thomas
2006-06-01
The use of retrospective occupational hygiene data for epidemiologic studies is useful in determining exposure-outcome relationships, but the potential for exposure misclassification is high. Although dust sampling in the South African coal industry has been a legal requirement for several decades, these historical data are not readily adequate for estimating past exposures. This study describes the respirable coal mine dust levels in three South African coal mines over time. Each of the participating mining operations had well-documented dust sampling information that was used to describe historical trends in dust exposure. Investigator-collected personal dust samples were taken using standardized techniques from the face, backbye (underground jobs not at the coal face), and surface from 50 miners at each mine, repeated over three sampling cycles. Job histories and exposure information was obtained from a sample of 684 current miners and 188 ex-miners. Linear models were developed to estimate the exposure levels associated with work in each mine, exposure zone, and over time using a combination of operator-collected historical data and investigator-collected samples. The estimated levels were then combined with work history information to calculate cumulative exposure metrics for the miner cohort. The mean historical and investigator-collected respirable dust levels were within international norms and South African standards. Silica content of the dust samples was also below the 5% regulatory action level. Mean respirable dust concentrations at the face, based on investigator-collected samples, were 0.9 mg/m(3), 1.3 mg/m(3), and 1.9 mg/m(3) at Mines 1, 2, and 3, respectively. The operator-collected samples showed considerable variability across exposure zones, mines, and time, with the annual means at the face ranging from 0.4 mg/m(3) to 2.9 mg/m(3). Statistically significant findings were found between operator- and investigator-collected dust samples. Model-based arithmetic mean dust estimates at the face were 1.2 mg/m(3), 2.0 mg/m(3), and 0.9 mg/m(3) for Mines 1, 2, and 3, respectively. Using these levels, the mean cumulative exposure for the cohort was 56.8 mg-years/m(3). Current miners had a mean cumulative exposure of 66.5 mg-years/m(3), compared with ex-miners of 26.8 mg-years/m(3). Improvements in dust management or the use of different sampling equipment could account for the significant differences seen between operator- and investigator-collected data. Regression modeling for estimating mean dust levels over time using combined historical and investigator-collected data seems a reasonable method and useful in constructing models to describe cumulative exposures in a cohort of current and ex-miners.
Oil refinery dusts: morphological and size analysis by TEM.
Sielicki, Przemysław; Janik, Helena; Guzman, Agnieszka; Broniszewski, Mieczysław; Namieśnik, Jacek
2011-03-01
The objectives of this work were to develop a means of sampling atmospheric dusts on the premises of an oil refinery for electron microscopic study to carry out preliminary morphological analyses and to compare these dusts with those collected at sites beyond the refinery limits. Carbon and collodion membranes were used as a support for collection of dust particles straight on transmission electron microscopy (TEM) grids. Micrographs of the dust particles were taken at magnifications from ×4,000 to ×80,000 with a Tesla BS500 transmission electron microscope. Four parameters were defined on the basis of the micrographs: surface area, Feret diameter, circumference, and shape coefficient. The micrographs and literature data were used to classify the atmospheric dusts into six groups: particles with an irregular shape and rounded edges; particles with an irregular shape and sharp edges; soot and its aggregates; spherical particles; singly occurring, ultrafine dust particles; and particles not allocated to any of the previous five groups. The types of dusts found in all the samples were similar, although differences did exist between the various morphological parameters. Dust particles with the largest Feret diameter were present in sample 3 (mean, 0.739 μm)-these were collected near the refinery's effluent treatment plant. The particles with the smallest diameter were found in the sample that had been intended to be a reference sample for the remaining results (mean, 0.326 μm). The dust particles collected in the refinery had larger mean Feret diameters, even 100% larger, than those collected beyond it. Particles with diameters from 0.1 to 0.2 μm made up the most numerous group in all the samples collected in the refinery.
Garrison, Virginia; Lamothe, Paul; Morman, Suzette; Plumlee, Geoffrey S.; Gilkes, Robert; Prakongkep, Nattaporn
2010-01-01
The Sahara and Sahel lose billions of tons of eroded mineral soils annually to the Americas and Caribbean, Europe and Asia via atmospheric transport. African dust was collected from a dust source region (Mali, West Africa) and from downwind sites in the Caribbean [Trinidad-Tobago (TT) and U.S. Virgin Islands (VI)] and analysed for 32 trace-elements. Elemental composition of African dust samples was similar to that of average upper continental crust (UCC), with some enrichment or depletion of specific trace-elements. Pb enrichment was observed only in dust and dry deposition samples from the source region and was most likely from local use of leaded gasoline. Dust particles transported long-distances (VI and TT) exhibited increased enrichment of Mo and minor depletion of other elements relative to source region samples. This suggests that processes occurring during long-distance transport of dust produce enrichment/depletion of specific elements. Bioaccessibility of trace-metals in samples was tested in simulated human fluids (gastric and lung) and was found to be greater in downwind than source region samples, for some metals (e.g., As). The large surface to volume ratio of the dust particles (<2.5 µm) at downwind sites may be a factor.
NASA Astrophysics Data System (ADS)
Laurent, B.; Losno, R.; Chevaillier, S.; Vincent, J.; Roullet, P.; Bon Nguyen, E.; Ouboulmane, N.; Triquet, S.; Fornier, M.; Raimbault, P.; Bergametti, G.
2015-07-01
Deposition is one of the key terms of the mineral dust cycle. However, dust deposition remains poorly constrained in transport models simulating the atmospheric dust cycle. This is mainly due to the limited number of relevant deposition measurements. This paper aims to present an automatic collector (CARAGA), specially developed to sample the total (dry and wet) atmospheric deposition of insoluble dust in remote areas. The autonomy of the CARAGA can range from 25 days to almost 1 year depending on the programmed sampling frequency (from 1 day to 2 weeks respectively). This collector is used to sample atmospheric deposition of Saharan dust on the Frioul islands in the Gulf of Lions in the Western Mediterranean. To quantify the mineral dust mass in deposition samples, a weighing and ignition protocol is applied. Almost 2 years of continuous deposition measurements performed on a weekly sampling basis on Frioul Island are presented and discussed with air mass trajectories and satellite observations of dust. Insoluble mineral deposition measured on Frioul Island was 2.45 g m-2 for February to December 2011 and 3.16 g m-2 for January to October 2012. Nine major mineral deposition events, measured during periods with significant MODIS aerosol optical depths, were associated with air masses coming from the southern Mediterranean Basin and North Africa.
Herich, Hanna; Tritscher, Torsten; Wiacek, Aldona; Gysel, Martin; Weingartner, Ernest; Lohmann, Ulrike; Baltensperger, Urs; Cziczo, Daniel J
2009-09-28
Airborne mineral dust particles serve as cloud condensation nuclei (CCN), thereby influencing the formation and properties of warm clouds. It is therefore of atmospheric interest how dust aerosols with different mineralogy behave when exposed to high relative humidity (RH) or supersaturation (SS) with respect to liquid water. In this study the subsaturated hygroscopic growth and the supersaturated cloud condensation nucleus activity of pure clays and real desert dust aerosols were determined using a hygroscopicity tandem differential mobility analyzer (HTDMA) and a cloud condensation nuclei counter (CCNC), respectively. Five different illite, montmorillonite and kaolinite clay samples as well as three desert dust samples (Saharan dust (SD), Chinese dust (CD) and Arizona test dust (ATD)) were investigated. Aerosols were generated both with a wet and a dry disperser. The water uptake was parameterized via the hygroscopicity parameter kappa. The hygroscopicity of dry generated dust aerosols was found to be negligible when compared to processed atmospheric aerosols, with CCNC derived kappa values between 0.00 and 0.02 (the latter corresponds to a particle consisting of 96.7% by volume insoluble material and approximately 3.3% ammonium sulfate). Pure clay aerosols were generally found to be less hygroscopic than natural desert dust particles. The illite and montmorillonite samples had kappa approximately 0.003. The kaolinite samples were less hygroscopic and had kappa=0.001. SD (kappa=0.023) was found to be the most hygroscopic dry-generated desert dust followed by CD (kappa=0.007) and ATD (kappa=0.003). Wet-generated dust showed an increased water uptake when compared to dry-generated samples. This is considered to be an artifact introduced by redistribution of soluble material between the particles. Thus, the generation method is critically important when presenting such data. These results indicate any atmospheric processing of a fresh mineral dust particle which leads to the addition of more than approximately 3% soluble material will significantly enhance its hygroscopicity and CCN activity.
Evaluation of Dust Exposure among the Workers in Agricultural Industries in North-East India.
Dewangan, Krishna N; Patil, Mahesh R
2015-11-01
This study aims to quantify dust exposure among the workers in four different industrial settings: rice mills, flour mills, oil mills, and tea factories and to compare the obtained data with the permissible exposure limit (PEL) of Indian Union Ministry of Labour as well as to compare the dust exposure across activities and seasons. RespiCon(TM) particle sampler was used for collecting dust concentration in the breathing zone of the workers. In total, 149 workers participated in the study and 204 samples were collected. Samples were collected in the vicinity of different processing operations. Samples in the rice mills were collected for two consecutive years in two seasons; however samples from other industries were collected for 1 year. The results indicate that geometric mean (GM) of dust exposure was significantly (P < 0.0001) different among industrial settings. Respirable dust were 8.22, 5.76, 2.98, and 6.34mg m(-3) and total dust exposure were 81.05, 111.02, 56.68, and 39.85mg m(-3) in the rice mills, oil mills, flour mills, and tea factories, respectively. Considerable variations in dust exposure were observed in different activities in the rice and oil mills; however variation was relatively less in the flour mills and tea factories. In the rice mills, dust concentration was higher in winter than those obtained in autumn and it is significantly different (P < 0.05) for inhalable dust and total dust. Positive correlation was obtained in thoracic dust (r (2) = 0.94) and inhalable dust (r (2) = 0.97) with total dust and thoracic dust with inhalable dust (r (2) = 0.89). The results show that majority of the workers are exposed to higher level of respirable dust as compared to the PEL, while total dust exposure to all the workers were higher than the PEL; thus, immediate reduction of dust exposure among the workers is necessary for preventing respiratory system impairment. © The Author 2015. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.
NASA Astrophysics Data System (ADS)
Kumar, S.; Aggarwal, S. G.; Fu, P. Q.; Kang, M.; Sarangi, B.; Sinha, D.; Kotnala, R. K.
2017-06-01
During March 20-22, 2012 Delhi experienced a massive dust-storm which originated in Middle-East. Size segregated sampling of these dust aerosols was performed using a nine staged Andersen sampler (5 sets of samples were collected including before dust-storm (BDS)), dust-storm day 1 to 3 (DS1 to DS3) and after dust storm (ADS). Sugars (mono and disaccharides, sugar-alcohols and anhydro-sugars) were determined using GC-MS technique. It was observed that on the onset of dust-storm, total suspended particulate matter (TSPM, sum of all stages) concentration in DS1 sample increased by > 2.5 folds compared to that of BDS samples. Interestingly, fine particulate matter (sum of stages with cutoff size < 2.1 μm) loading in DS1 also increased by > 2.5 folds as compared to that of BDS samples. Sugars analyzed in DS1 coarse mode (sum of stages with cutoff size > 2.1 μm) samples showed a considerable increase ( 1.7-2.8 folds) compared to that of other samples. It was further observed that mono-saccharides, disaccharides and sugar-alcohols concentrations were enhanced in giant (> 9.0 μm) particles in DS1 samples as compared to other samples. On the other hand, anhydro-sugars comprised 13-27% of sugars in coarse mode particles and were mostly found in fine mode constituting 66-85% of sugars in all the sample types. Trehalose showed an enhanced ( 2-4 folds) concentration in DS1 aerosol samples in both coarse (62.80 ng/m3) and fine (8.57 ng/m3) mode. This increase in Trehalose content in both coarse and fine mode suggests their origin to the transported desert dust and supports their candidature as an organic tracer for desert dust entrainments. Further, levoglucosan to mannosan (L/M) ratios which have been used to predict the type of biomass burning influences on aerosols are found to be size dependent in these samples. These ratios are higher for fine mode particles, hence should be used with caution while interpreting the sources using this tool.
Silica dust exposure: Effect of filter size to compliance determination
NASA Astrophysics Data System (ADS)
Amran, Suhaily; Latif, Mohd Talib; Khan, Md Firoz; Leman, Abdul Mutalib; Goh, Eric; Jaafar, Shoffian Amin
2016-11-01
Monitoring of respirable dust was performed using a set of integrated sampling system consisting of sampling pump attached with filter media and separating device such as cyclone or special cassette. Based on selected method, filter sizes are either 25 mm or 37 mm poly vinyl chloride (PVC) filter. The aim of this study was to compare performance of two types of filter during personal respirable dust sampling for silica dust under field condition. The comparison strategy focused on the final compliance judgment based on both dataset. Eight hour parallel sampling of personal respirable dust exposure was performed among 30 crusher operators at six quarries. Each crusher operator was attached with parallel set of integrated sampling train containing either 25 mm or 37 mm PVC filter. Each set consisted of standard flow SKC sampler, attached with SKC GS3 cyclone and 2 pieces cassette loaded with 5.0 µm of PVC filter. Samples were analyzed by gravimetric technique. Personal respirable dust exposure between the two types of filters indicated significant positive correlation (p < 0.05) with moderate relationship (r2 = 0.6431). Personal exposure based on 25 mm PVC filter indicated 0.1% non-compliance to overall data while 37 mm PVC filter indicated similar findings at 0.4 %. Both data showed similar arithmetic mean(AM) and geometric mean(GM). In overall we concluded that personal respirable dust exposure either based on 25mm or 37mm PVC filter will give similar compliance determination. Both filters are reliable to be used in respirable dust monitoring for silica dust related exposure.
NASA Astrophysics Data System (ADS)
Mockford, T.; Zobeck, T. M.; Lee, J. A.; Gill, T. E.; Dominguez, M. A.; Peinado, P.
2012-12-01
Understanding the controls of mineral dust emissions and their particle size distributions during wind-erosion events is critical as dust particles play a significant impact in shaping the earth's climate. It has been suggested that emission rates and particle size distributions are independent of soil chemistry and soil texture. In this study, 45 samples of wind-erodible surface soils from the Southern High Plains and Chihuahuan Desert regions of Texas, New Mexico, Colorado and Chihuahua were analyzed by the Lubbock Dust Generation, Analysis and Sampling System (LDGASS) and a Beckman-Coulter particle multisizer. The LDGASS created dust emissions in a controlled laboratory setting using a rotating arm which allows particle collisions. The emitted dust was transferred to a chamber where particulate matter concentration was recorded using a DataRam and MiniVol filter and dust particle size distribution was recorded using a GRIMM particle analyzer. Particle size analysis was also determined from samples deposited on the Mini-Vol filters using a Beckman-Coulter particle multisizer. Soil textures of source samples ranged from sands and sandy loams to clays and silts. Initial results suggest that total dust emissions increased with increasing soil clay and silt content and decreased with increasing sand content. Particle size distribution analysis showed a similar relationship; soils with high silt content produced the widest range of dust particle sizes and the smallest dust particles. Sand grains seem to produce the largest dust particles. Chemical control of dust emissions by calcium carbonate content will also be discussed.
Seasonal provenance changes in present-day Saharan dust collected in and off Mauritania
NASA Astrophysics Data System (ADS)
Friese, Carmen A.; van Hateren, Johannes A.; Vogt, Christoph; Fischer, Gerhard; Stuut, Jan-Berend W.
2017-08-01
Saharan dust has a crucial influence on the earth climate system and its emission, transport and deposition are intimately related to, e.g., wind speed, precipitation, temperature and vegetation cover. The alteration in the physical and chemical properties of Saharan dust due to environmental changes is often used to reconstruct the climate of the past. However, to better interpret possible climate changes the dust source regions need to be known. By analysing the mineralogical composition of transported or deposited dust, potential dust source areas can be inferred. Summer dust transport off northwest Africa occurs in the Saharan air layer (SAL). In continental dust source areas, dust is also transported in the SAL; however, the predominant dust input occurs from nearby dust sources with the low-level trade winds. Hence, the source regions and related mineralogical tracers differ with season and sampling location. To test this, dust collected in traps onshore and in oceanic sediment traps off Mauritania during 2013 to 2015 was analysed. Meteorological data, particle-size distributions, back-trajectory and mineralogical analyses were compared to derive the dust provenance and dispersal. For the onshore dust samples, the source regions varied according to the seasonal changes in trade-wind direction. Gibbsite and dolomite indicated a Western Saharan and local source during summer, while chlorite, serpentine and rutile indicated a source in Mauritania and Mali during winter. In contrast, for the samples that were collected offshore, dust sources varied according to the seasonal change in the dust transporting air layer. In summer, dust was transported in the SAL from Mauritania, Mali and Libya as indicated by ferroglaucophane and zeolite. In winter, dust was transported with the trades from Western Sahara as indicated by, e.g., fluellite.
NASA Technical Reports Server (NTRS)
Westphal, Andrew J.; Butterworth, Anna L.; Snead, Christopher J.; Craig, Nahide; Anderson, David; Jones, Steven M.; Brownlee, Donald E.; Farnsworth, Richard; Zolensky, Michael E.
2005-01-01
In January 2006, the Stardust mission will return the first samples from a solid solar system body beyond the Moon. Stardust was in the news in January 2004, when it encountered comet Wild2 and captured a sample of cometary dust. But Stardust carries an equally important payload: the first samples of contemporary interstellar dust ever collected. Although it is known that interstellar (IS) dust penetrates into the inner solar system [2, 3], to date not even a single contemporary interstellar dust particle has been captured and analyzed in the laboratory. Stardust uses aerogel collectors to capture dust samples. Identification of interstellar dust impacts in the Stardust Interstellar Dust Collector probably cannot be automated, but will require the expertise of the human eye. However, the labor required for visual scanning of the entire collector would exceed the resources of any reasonably-sized research group. We are developing a project to recruit the public in the search for interstellar dust, based in part on the wildly popular SETI@home project, which has five million subscribers. We call the project Stardust@home. Using sophisticated chemical separation techniques, certain types of refractory ancient IS particles (so-called presolar grains) have been isolated from primitive meteorites (e.g., [4] ). Recently, presolar grains have been identified in Interplanetary Dust Particles[6]. Because these grains are not isolated chemically, but are recognized only by their unusual isotopic compositions, they are probably less biased than presolar grains isolated from meteorites. However, it is entirely possible that the typical interstellar dust particle is isotopically solar in composition. The Stardust collection of interstellar dust will be the first truly unbiased one.
Atmospheric microbiology in the northern Caribbean during African dust events
Griffin, Dale W.; Kellogg, C.A.; Garrison, V.H.; Lisle, J.T.; Borden, T.C.; Shinn, E.A.
2003-01-01
Between July 2000 and August 2001 forty-three air samples were collected in the northern Caribbean: Twenty-six in the US Virgin Islands, and 17 samples aboard ship during two 1-week cruises. Samples were collected during African dust events and non-dust conditions and screened for the presence of culturable bacteria and fungi. A total of 3,652 liters of air were collected during non-dust conditions, with 19 bacteria and 28 fungi being recovered. During dust conditions a total of 2,369 liters of air were screened resulting in the recovery of 171 bacteria and 76 fungi. A statistically significant difference was found between the two data sets. These results support previous African dust research and further demonstrate that dust particles can serve as a vessel for the global dispersion of bacteria and fungi. Dustborne microorganisms may play a significant role in the ecology and health of downwind ecosystems.
NASA Technical Reports Server (NTRS)
2006-01-01
2 February 2006 This Mars Global Surveyor (MGS) Mars Orbiter Camera (MOC) image shows polygonally patterned ground on the floor of a trough in the southern hemisphere of Mars. The polygons could be an indicator that ground ice is or was present at this location. The dark streaks were formed by passing dust devils. Location near: 67.4oS, 240.3oW Image width: 3 km (1.9 mi) Illumination from: upper left Season: Southern SummerNASA Technical Reports Server (NTRS)
2005-01-01
29 December 2005 This Mars Global Surveyor (MGS) Mars Orbiter Camera (MOC) image shows house-sized boulders and layered volcanic rock exposed in a pit on the north flank of the giant Tharsis volcano, Ascraeus Mons. The pit most likely formed by collapse. Dust mantles much of the surrounding terrain and the pit floor. Location near: 12.9oN, 101.6oW Image width: 3 km (1.9 mi) Illumination from: lower left Season: Southern WinterRECOMMENDATIONS FOR SAMPLING OF TANK 19 IN F TANK FARM
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harris, S.; Shine, G.
2009-12-14
Representative sampling is required for characterization of the residual material in Tank 19 prior to operational closure. Tank 19 is a Type IV underground waste storage tank located in the F-Tank Farm. It is a cylindrical-shaped, carbon steel tank with a diameter of 85 feet, a height of 34.25 feet, and a working capacity of 1.3 million gallons. Tank 19 was placed in service in 1961 and initially received a small amount of low heat waste from Tank 17. It then served as an evaporator concentrate (saltcake) receiver from February 1962 to September 1976. Tank 19 also received the spentmore » zeolite ion exchange media from a cesium removal column that once operated in the Northeast riser of the tank to remove cesium from the evaporator overheads. Recent mechanical cleaning of the tank removed all mounds of material. Anticipating a low level of solids in the residual waste, Huff and Thaxton [2009] developed a plan to sample the waste during the final clean-up process while it would still be resident in sufficient quantities to support analytical determinations in four quadrants of the tank. Execution of the plan produced fewer solids than expected to support analytical determinations in all four quadrants. Huff and Thaxton [2009] then restructured the plan to characterize the residual separately in the North and the South regions: two 'hemispheres.' This document provides sampling recommendations to complete the characterization of the residual material on the tank bottom following the guidance in Huff and Thaxton [2009] to split the tank floor into a North and a South hemisphere. The number of samples is determined from a modification of the formula previously published in Edwards [2001] and the sample characterization data for previous sampling of Tank 19 described by Oji [2009]. The uncertainty is quantified by an upper 95% confidence limit (UCL95%) on each analyte's mean concentration in Tank 19. The procedure computes the uncertainty in analyte concentration as a function of the number of samples, and the final number of samples is determined when the reduction in the uncertainty from an additional sample no longer has a practical impact on results. The characterization of the full suite of analytes in the North and South hemispheres is currently supported by a single Mantis rover sample in each hemisphere. A floor scrape sample was obtained from a compact region near the center riser slightly in the South hemisphere and has been analyzed for a shortened list of key analytes. There is not enough additional material from the floor scrape sample material for completing the full suite of constituents. No floor scrape samples have been previously taken from the North hemisphere. The criterion to determine the number of additional samples was based on the practical reduction in the uncertainty when a new sample is added. This was achieved when five additional samples are obtained. In addition, two archived samples will be used if a contingency such as failing to demonstrate the comparability of the Mantis samples to the floor scrape samples occurs. To complete sampling of the Tank 19 residual floor material, four additional samples should be taken from the North hemisphere and four additional samples should be taken from the South hemisphere. One of the samples from each hemisphere will be archived in case of need. Three of the four additional samples from each hemisphere will be analyzed. Once the results are available, differences between the Mantis and three floor scrape sample results will be evaluated. If there are no statistically significant analyte concentration differences between the Mantis and floor scrape samples, those results will be combined and then UCL95%s will be calculated. If the analyte concentration differences between the Mantis and floor scrape samples are statistically significant, the UCL95%s will be calculated without the Mantis sample results. If further reduction in the upper confidence limits is needed and can be achieved by the addition of the archived samples, they will be analyzed and included in the statistical computations. Initially the analyte concentrations in the residual material on the floor of Tank 19 will be determined separately in the North and the South hemispheres. However, if final sampling results show that differences between the North and South samples are consistent within sampling variation, then the final computations can be based on consolidating all sample results from the tank floor. Recommended locations may be subject to physical tank access and sampling constraints for the additional samples. The recommendations have been discussed in Section 4 and are based on partitioning the Tank 19 floor into an inner and an outer ring and six 60{sup o} sectors depicted in Figure 1. The location of the border between the inner and outer rings is based on dividing the residual material into two approximately equal volumes.« less
30 CFR 70.209 - Respirable dust samples; transmission by operator.
Code of Federal Regulations, 2010 CFR
2010-07-01
... operator shall not open or tamper with the seal of any filter cassette or alter the weight of any filter... accordance with § 70.202 (Certified person; sampling) shall properly complete the dust data card that is.... Respirable dust samples with data cards not properly completed will be voided by MSHA. (d) All respirable...
30 CFR 70.209 - Respirable dust samples; transmission by operator.
Code of Federal Regulations, 2011 CFR
2011-07-01
... operator shall not open or tamper with the seal of any filter cassette or alter the weight of any filter... accordance with § 70.202 (Certified person; sampling) shall properly complete the dust data card that is.... Respirable dust samples with data cards not properly completed will be voided by MSHA. (d) All respirable...
Geochemical evidence for diversity of dust sources in the southwestern United States
Reheis, M.C.; Budahn, J.R.; Lamothe, P.J.
2002-01-01
Several potential dust sources, including generic sources of sparsely vegetated alluvium, playa deposits, and anthropogenic emissions, as well as the area around Owens Lake, California, affect the composition of modern dust in the southwestern United States. A comparison of geochemical analyses of modern and old (a few thousand years) dust with samples of potential local sources suggests that dusts reflect four primary sources: (1) alluvial sediments (represented by Hf, K, Rb, Zr, and rare-earth elements, (2) playas, most of which produce calcareous dust (Sr, associated with Ca), (3) the area of Owens (dry) Lake, a human-induced playa (As, Ba, Li, Pb, Sb, and Sr), and (4) anthropogenic and/or volcanic emissions (As, Cr, Ni, and Sb). A comparison of dust and source samples with previous analyses shows that Owens (dry) Lake and mining wastes from the adjacent Cerro Gordo mining district are the primary sources of As, Ba, Li, and Pb in dusts from Owens Valley. Decreases in dust contents of As, Ba, and Sb with distance from Owens Valley suggest that dust from southern Owens Valley is being transported at least 400 km to the east. Samples of old dust that accumulated before European settlement are distinctly lower in As, Ba, and Sb abundances relative to modern dust, likely due to modern transport of dust from Owens Valley. Thus, southern Owens Valley appears to be an important, geochemically distinct, point source for regional dust in the southwestern United States. Copyright ?? 2002 Elsevier Science Ltd.
Stardust Imaging of Comet Wild 2: First Look
NASA Technical Reports Server (NTRS)
Newburn, R.; Acton, C.; Bhaskaran, S.; Brownlee, D.; Cheuvront, A.; Duxbury, T.; Hanner, M.; Semenov, B.; Sandford, S.; Tsou, P.
2004-01-01
On 2 January 2004 during its historic flight to return cometary dust samples to earth, the STARDUST spacecraft flew within the coma of comet Wild 2 and also took 72 images where the surface was resolved during the flyby. A combination of long and short exposures was used to observe the jets and the surface. Comet Surface: The images revealed a planetary body, one not having a significant atmosphere, quite different from any other such body seen from other spacecraft. Surface depressions, potentially a combination of craters and vents, were not bowl-shaped but typically had steep walls and flattened floors. One depression considered to be a vent, the source of a jet, had a depth to diameter ratio of approx.0.4, with near vertical walls. Jets: At least 10 to possibly 20 jets were active during the flyby. Some were traced back to the surface where they seem to originate from the near vertical walls of depressions (vents) that were facing the sun, having the highest solar insolation.
Fungal Microbiomes Associated with Green and Non-Green Building Materials
Coombs, Kanistha; Vesper, Stephen; Green, Brett J.; Yermakov, Mikhail; Reponen, Tiina
2018-01-01
Water-damaged buildings can lead to fungal growth and occupant health problems. Green building materials, derived from renewable sources, are increasingly utilized in construction and renovations. However, the question as to what fungi will grow on these green compared to non-green materials, after they get wet, has not been adequately studied. By determining what fungi grow on each type of material, the potential health risks can be more adequately assessed. In this study, we inoculated green and non-green pieces of ceiling tile, composite board, drywall, and flooring with indoor dust containing a complex mixture of naturally occurring fungi. The materials were saturated with water and incubated for two months in a controlled environment. The resulting fungal microbiomes were evaluated using ITS amplicon sequencing. Overall, the richness and diversity of the mycobiomes on each pair of green and non-green pieces were not significantly different. However, different genera dominated on each type of material. For example, Aspergillus spp. had the highest relative abundance on green and non-green ceiling tiles and green composite boards, but Peniophora spp. dominated the non-green composite board. In contrast, Penicillium spp. dominated green and non-green flooring samples. Green gypsum board was dominated by Phialophora spp. and Stachybotrys spp., but non-green gypsum board by Myrothecium spp. These data suggest that water-damaged green and non-green building materials can result in mycobiomes that are dominated by fungal genera whose member species pose different potentials for health risks. PMID:29681691
Fungal Microbiomes Associated with Green and Non-Green Building Materials.
Coombs, Kanistha; Vesper, Stephen; Green, Brett J; Yermakov, Mikhail; Reponen, Tiina
2017-01-01
Water-damaged buildings can lead to fungal growth and occupant health problems. Green building materials, derived from renewable sources, are increasingly utilized in construction and renovations. However, the question as to what fungi will grow on these green compared to non-green materials, after they get wet, has not been adequately studied. By determining what fungi grow on each type of material, the potential health risks can be more adequately assessed. In this study, we inoculated green and non-green pieces of ceiling tile, composite board, drywall, and flooring with indoor dust containing a complex mixture of naturally occurring fungi. The materials were saturated with water and incubated for two months in a controlled environment. The resulting fungal microbiomes were evaluated using ITS amplicon sequencing. Overall, the richness and diversity of the mycobiomes on each pair of green and non-green pieces were not significantly different. However, different genera dominated on each type of material. For example, Aspergillus spp. had the highest relative abundance on green and non-green ceiling tiles and green composite boards, but Peniophora spp. dominated the non-green composite board. In contrast, Penicillium spp. dominated green and non-green flooring samples. Green gypsum board was dominated by Phialophora spp. and Stachybotrys spp., but non-green gypsum board by Myrothecium spp. These data suggest that water-damaged green and non-green building materials can result in mycobiomes that are dominated by fungal genera whose member species pose different potentials for health risks.
Dust: a metric for use in residential and building exposure assessment and source characterization.
Lioy, Paul J; Freeman, Natalie C G; Millette, James R
2002-01-01
In this review, we examine house dust and residential soil and their use for identifying sources and the quantifying levels of toxicants for the estimation of exposure. We answer critical questions that focus on the selection of samples or sampling strategies for collection and discuss areas of uncertainty and gaps in knowledge. We discuss the evolution of dust sampling with a special emphasis on work conducted after the publication of the 1992 review by McArthur [Appl Occup Environ Hyg 7(9):599-606 (1992)]. The approaches to sampling dust examined include surface wipe sampling, vacuum sampling, and other sampling approaches, including attic sampling. The metrics of presentation of results for toxicants in dust surface loading (micrograms per square centimeter) or surface concentration (micrograms per gram) are discussed. We evaluate these metrics in terms of how the information can be used in source characterization and in exposure characterization. We discuss the types of companion information on source use and household or personal activity patterns required to assess the significance of the dust exposure. The status and needs for wipe samplers, surface samplers, and vacuum samplers are summarized with some discussion on the strengths and weaknesses of each type of sampler. We also discuss needs for research and development and the current status of standardization. Case studies are provided to illustrate the use of house dust and residential soil in source characterization, forensic analyses, or human exposure assessment. PMID:12361921
Dust: a metric for use in residential and building exposure assessment and source characterization.
Lioy, Paul J; Freeman, Natalie C G; Millette, James R
2002-10-01
In this review, we examine house dust and residential soil and their use for identifying sources and the quantifying levels of toxicants for the estimation of exposure. We answer critical questions that focus on the selection of samples or sampling strategies for collection and discuss areas of uncertainty and gaps in knowledge. We discuss the evolution of dust sampling with a special emphasis on work conducted after the publication of the 1992 review by McArthur [Appl Occup Environ Hyg 7(9):599-606 (1992)]. The approaches to sampling dust examined include surface wipe sampling, vacuum sampling, and other sampling approaches, including attic sampling. The metrics of presentation of results for toxicants in dust surface loading (micrograms per square centimeter) or surface concentration (micrograms per gram) are discussed. We evaluate these metrics in terms of how the information can be used in source characterization and in exposure characterization. We discuss the types of companion information on source use and household or personal activity patterns required to assess the significance of the dust exposure. The status and needs for wipe samplers, surface samplers, and vacuum samplers are summarized with some discussion on the strengths and weaknesses of each type of sampler. We also discuss needs for research and development and the current status of standardization. Case studies are provided to illustrate the use of house dust and residential soil in source characterization, forensic analyses, or human exposure assessment.
Argyraki, Ariadne
2014-08-01
The relationships between two exposure media, garden soil and house dust, were studied for Pb uptake in Stratoni village in northern Greece, an industrial area of mining and processing of sulphide ore. Lead data for the two media were assessed in terms of total and bioaccessible content, measurement and geochemical variability, and mineralogical composition. It was found that total Pb was enriched in house dust samples by a factor of 2 on average. Total Pb concentration in soil samples had a maximum of 2,040 mg/kg and reached a maximum of 7,000 mg/kg in house dust samples. The estimated variability due to measurement uncertainty was dominated by the sampling process, and the proportion of sampling variance was greater for soil samples, indicating a higher degree of Pb heterogeneity in soil on the given spatial scale of sampling strata. Although the same general spatial trend was observed for both sampling media with decreasing Pb concentration by increasing distance from the ore-processing plant, Pb in dust samples displayed the highest concentrations within a 300-600-m zone from the ore-processing facility. The significant differences which were observed in Pb speciation between the studied media were explained by differences in mineralogical composition of outdoor soil and indoor dust. Lead-enriched Fe and Mn oxides predominated in soil samples while fine galena grains (<10-20 μm diameter) were the major Pb-bearing phase in dust samples. The integrated exposure uptake biokinetic model was used to predict the risk of elevated blood lead levels in children of Stratoni. Model prediction indicated an average probability of 61 % for blood-Pb to exceed 10 μg/dl. The results underline the importance of house dust in risk assessment and highlight the effect of outdoor and indoor conditions on the fate of Pb in the particular environment of Stratoni.
Saharan dust - A carrier of persistent organic pollutants, metals and microbes to the Caribbean?
Garrison, V.H.; Foreman, W.T.; Genualdi, S.; Griffin, Dale W.; Kellogg, C.A.; Majewski, M.S.; Mohammed, A.; Ramsubhag, A.; Shinn, E.A.; Simonich, S.L.; Smith, G.W.
2006-01-01
An international team of scientists from government agencies and universities in the United States, U.S. Virgin Islands (USVI), Trinidad & Tobago, the Republic of Cape Verde, and the Republic of Mali (West Africa) is working together to elucidate the role Saharan dust may play in the degradation of Caribbean ecosystems. The first step has been to identify and quantify the persistent organic pollutants (POPs), trace metals, and viable microorganisms in the atmosphere in dust source areas of West Africa, and in dust episodes at downwind sites in the eastern Atlantic (Cape Verde) and the Caribbean (USVI and Trinidad & Tobago). Preliminary findings show that air samples from Mali contain a greater number of pesticides, polychlorinated biphenyls (PCBs) and polycyclic aromatic hydrocarbons (PAHs) and in higher concentrations than the Caribbean sites. Overall, POP concentrations were similar in USVI and Trinidad samples. Trace metal concentrations were found to be similar to crustal composition with slight enrichment of lead in Mali. To date, hundreds of cultureable micro-organisms have been identified from Mali, Cape Verde, USVI, and Trinidad air samples. The sea fan pathogen, Aspergillus sydowii, has been identified in soil from Mali and in air samples from dust events in the Caribbean. We have shown that air samples from a dust-source region contain orders of magnitude more cultureable micro-organisms per volume than air samples from dust events in the Caribbean, which in turn contain 3-to 4-fold more cultureable microbes than during non-dust conditions.
Dust emissions of organic soils observed in the field and laboratory
NASA Astrophysics Data System (ADS)
Zobeck, T. M.; Baddock, M. C.; Guo, Z.; Van Pelt, R.; Acosta-Martinez, V.; Tatarko, J.
2011-12-01
According to the U.S. Soil Taxonomy, Histosols (also known as organic soils) are soils that are dominated by organic matter (>20% organic matter) in half or more of the upper 80 cm. These soils, when intensively cropped, are subject to wind erosion resulting in loss in crop productivity and degradation of soil, air, and water quality. Estimating wind erosion on Histosols has been determined by USDA-Natural Resources Conservation Service as a critical need for the Wind Erosion Prediction System (WEPS) model. WEPS has been developed to simulate wind erosion on agricultural land in the US, including soils with organic soil material surfaces. However, additional field measurements are needed to calibrate and validate estimates of wind erosion of organic soils using WEPS. In this study, we used a field portable wind tunnel to generate suspended sediment (dust) from agricultural surfaces for soils with a range of organic contents. The soils were tilled and rolled to provide a consolidated, friable surface. Dust emissions and saltation were measured using an isokinetic vertical slot sampler aspirated by a regulated suction source. Suspended dust was collected on filters of the dust slot sampler and sampled at a frequency of once every six seconds in the suction duct using a GRIMM optical particle size analyzer. In addition, bulk samples of airborne dust were collected using a sampler specifically designed to collect larger dust samples. The larger dust samples were analyzed for physical, chemical, and microbiological properties. In addition, bulk samples of the soils were tested in a laboratory wind tunnel similar to the field wind tunnel and a laboratory dust generator to compare field and laboratory results. For the field wind tunnel study, there were no differences between the highest and lowest organic content soils in terms of their steady state emission rate under an added abrader flux, but the soil with the mid-range of organic matter had less emission by one third. In the laboratory wind tunnel, samples with the same ratio of erodible to non-erodible aggregates as the field soils were abraded and dust emissions were observed with the same sampling system as used in the field wind tunnel. In the dust generator, 5 gm samples < 8 mm diameter of each organic soil were rotated in a 50 cm long tube and the dust generated was observed with the GRIMM during a 20 minute run. Comparisons of the field dust emission rates with the laboratory results will be presented.
Sea-floor morphology and sedimentary environments in southern Narragansett Bay, Rhode Island
McMullen, Katherine Y.; Poppe, Lawrence J.; Blackwood, Dann S.; Nardi, Matthew J.; Andring, Matthew A.
2015-09-09
Multibeam echosounder data collected by the National Oceanic and Atmospheric Administration along with sediment samples and still and video photography of the sea floor collected by the U.S. Geological Survey were used to interpret sea-floor features and sedimentary environments in southern Narragansett Bay, Rhode Island, as part of a long-term effort to map the sea floor along the northeastern coast of the United States. Sea-floor features include rocky areas and scour depressions in high-energy environments characterized by erosion or nondeposition, and sand waves and megaripples in environments characterized by coarse-grained bedload transport. Two shipwrecks are also located in the study area. Much of the sea floor is relatively featureless within the resolution of the multibeam data; sedimentary environments in these areas are characterized by processes associated with sorting and reworking. This report releases bathymetric data from the multibeam echosounder, grain-size analyses of sediment samples, and photographs of the sea floor and interpretations of the sea-floor features and sedimentary environments. It provides base maps that can be used for resource management and studies of topics such as benthic ecology, contaminant inventories, and sediment transport.
2003-03-13
This false-color infrared image was taken by the camera system on the Mars Odyssey spacecraft over part of Ganges Chasma in Valles Marineris (approximately 13 degrees S, 318 degrees E). The infrared image has been draped over topography data obtained by Mars Global Surveyor. The color differences in this image show compositional variations in the rocks exposed in the wall and floor of Ganges (blue and purple) and in the dust and sand on the rim of the canyon (red and orange). The floor of Ganges is covered by rocks and sand composed of basaltic lava that are shown in blue. A layer that is rich in the mineral olivine can be seen as a band of purple in the walls on both sides of the canyon, and is exposed as an eroded layer surrounding a knob on the floor. Olivine is easily destroyed by liquid water, so its presence in these ancient rocks suggests that this region of Mars has been very dry for a very long time. The mosaic was constructed using infrared bands 5, 7, and 8, and covers an area approximately 150 kilometers (90 miles) on each side. This simulated view is toward the north. http://photojournal.jpl.nasa.gov/catalog/PIA04262
Tran, Tri Manh; Abualnaja, Khalid O; Asimakopoulos, Alexandros G; Covaci, Adrian; Gevao, Bondi; Johnson-Restrepo, Boris; Kumosani, Taha A; Malarvannan, Govindan; Minh, Tu Binh; Moon, Hyo-Bang; Nakata, Haruhiko; Sinha, Ravindra K; Kannan, Kurunthachalam
2015-05-01
Siloxanes are used widely in a variety of consumer products, including cosmetics, personal care products, medical and electrical devices, cookware, and building materials. Nevertheless, little is known on the occurrence of siloxanes in indoor dust. In this survey, five cyclic (D3-D7) and 11 linear (L4-L14) siloxanes were determined in 310 indoor dust samples collected from 12 countries. Dust samples collected from Greece contained the highest concentrations of total cyclic siloxanes (TCSi), ranging from 118 to 25,100ng/g (median: 1380), and total linear siloxanes (TLSi), ranging from 129 to 4990ng/g (median: 772). The median total siloxane (TSi) concentrations in dust samples from 12 countries were in the following decreasing order: Greece (2970ng/g), Kuwait (2400), South Korea (1810), Japan (1500), the USA (1220), China (1070), Romania (538), Colombia (230), Vietnam (206), Saudi Arabia (132), India (116), and Pakistan (68.3). TLSi concentrations as high as 42,800ng/g (Kuwait) and TCSi concentrations as high as 25,000ng/g (Greece) were found in indoor dust samples. Among the 16 siloxanes determined, decamethylcyclopentasiloxane (D5) was found at the highest concentration in dust samples from all countries, except for Japan and South Korea, with a predominance of L11; Kuwait, with L10; and Pakistan and Romania, with L12. The composition profiles of 16 siloxanes in dust samples varied by country. TCSi accounted for a major proportion of TSi concentrations in dust collected from Colombia (90%), India (80%) and Saudi Arabia (70%), whereas TLSi predominated in samples collected from Japan (89%), Kuwait (85%), and South Korea (78%). Based on the measured median TSi concentrations in indoor dust, we estimated human exposure doses through indoor dust ingestion for various age groups. The exposure doses ranged from 0.27 to 11.9ng/kg-bw/d for toddlers and 0.06 to 2.48ng/kg-bw/d for adults. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Qi, Jianhua; Liu, Xiaohuan; Yao, Xiaohong; Zhang, Ruifeng; Chen, Xiaojing; Lin, Xuehui; Gao, Huiwang; Liu, Ruhai
2018-01-01
Asian dust has been reported to carry anthropogenic reactive nitrogen during transport from source areas to the oceans. In this study, we attempted to characterize NH4+ and NO3- in atmospheric particles collected at a coastal site in northern China during spring dust events from 2008 to 2011. Based on the mass concentrations of NH4+ and NO3- in each total suspended particle (TSP) sample, the samples can be classified into increasing or decreasing types. In Category 1, the concentrations of NH4+ and NO3- were 20-440 % higher in dust day samples relative to samples collected immediately before or after a dust event. These concentrations decreased by 10-75 % in the dust day samples in Categories 2 and 3. Back trajectory analysis suggested that multiple factors, such as the transport distance prior to the reception site, the mixing layer depth on the transport route and the residence time across highly polluted regions, might affect the concentrations of NH4+ and NO3-. NH4+ in the dust day samples was likely either in the form of ammonium salts existing separately to dust aerosols or as the residual of incomplete reactions between ammonium salts and carbonate salts. NO3- in the dust day samples was attributed to various formation processes during the long-range transport. The positive matrix factorization (PMF) receptor model results showed that the contribution of soil dust increased from 23 to 36 % on dust days, with decreasing contributions from local anthropogenic inputs and associated secondary aerosols. The estimated deposition flux of NNH4++NO3- varied greatly from event to event; e.g., the dry deposition flux of NNH4++NO3- increased by 9-285 % in Category 1 but decreased by 46-73 % in Category 2. In Category 3, the average dry deposition fluxes of particulate nitrate and ammonium decreased by 46 % and increased by 10 %, respectively, leading to 11-48 % decrease in the fluxes of NNH4++NO3-.
In Situ Sampling of Relative Dust Devil Particle Loads and Their Vertical Grain Size Distributions.
Raack, Jan; Reiss, Dennis; Balme, Matthew R; Taj-Eddine, Kamal; Ori, Gian Gabriele
2017-04-19
During a field campaign in the Sahara Desert in southern Morocco, spring 2012, we sampled the vertical grain size distribution of two active dust devils that exhibited different dimensions and intensities. With these in situ samples of grains in the vortices, it was possible to derive detailed vertical grain size distributions and measurements of the lifted relative particle load. Measurements of the two dust devils show that the majority of all lifted particles were only lifted within the first meter (∼46.5% and ∼61% of all particles; ∼76.5 wt % and ∼89 wt % of the relative particle load). Furthermore, ∼69% and ∼82% of all lifted sand grains occurred in the first meter of the dust devils, indicating the occurrence of "sand skirts." Both sampled dust devils were relatively small (∼15 m and ∼4-5 m in diameter) compared to dust devils in surrounding regions; nevertheless, measurements show that ∼58.5% to 73.5% of all lifted particles were small enough to go into suspension (<31 μm, depending on the used grain size classification). This relatively high amount represents only ∼0.05 to 0.15 wt % of the lifted particle load. Larger dust devils probably entrain larger amounts of fine-grained material into the atmosphere, which can have an influence on the climate. Furthermore, our results indicate that the composition of the surface, on which the dust devils evolved, also had an influence on the particle load composition of the dust devil vortices. The internal particle load structure of both sampled dust devils was comparable related to their vertical grain size distribution and relative particle load, although both dust devils differed in their dimensions and intensities. A general trend of decreasing grain sizes with height was also detected. Key Words: Mars-Dust devils-Planetary science-Desert soils-Atmosphere-Grain sizes. Astrobiology 17, xxx-xxx.
TRW RECOMMENDATIONS FOR THE SAMPLING AND ANALYSIS OF INDOOR RESIDENTIAL DUST FOR THE IEUBK MODEL
The purpose of this guidance document is to recommend methods for collecting and analyzing residential dust lead data specifically for use in the IEUBK model. A discussion of other dust sampling methods is also included.
Characterizing Mineral Dust from the Arabian Coast of the Red Sea
NASA Astrophysics Data System (ADS)
Puthan Purakkal, J.; Stenchikov, G. L.; Engelbrecht, J. P.
2014-12-01
The Arabian Peninsula is one of the Earth's major sources of atmospheric dust. Along with profound negative effects on human activity and natural processes in this region, dust is an important nutrient source for the oligothrophic northern Red Sea. From preliminary observations it is estimated that some 18-20 major dust storms per year deposit about 6 Mt of mineral dust into the Red Sea. To better understand the optical properties, health, and ecological impacts of dust, we study the mineralogical, chemical and morphological properties of surface soil samples collected at prevbiously identified potential dust sources along the Arabian coast of the Red Sea. Many of these dust sources lie within a narrow coastal region and because of their proximity to the Red Sea, are important contributors to the dust/nutrient balance, during both dusty and fair weather conditions. Bulk samples were collected from the top 10 mm of soils from three sites along the Arabian coast of the Red Sea. The soil samples were sieved to separate the < 38μm particle fractions for chemical and mineralogical analysis. X-ray diffractometry (XRD) was applied to measure the mineral content of the dust. The chemical composition of individual particles was analyzed using scanning electron microscopy (SEM) with energy dispersive spectroscopy (EDS). From the XRD analysis of the sieved samples from An Masayat (23.3322 N, 38.9481 E), Buthna (23.2960 N, 38.9384 E) and Rabugh pipeline Road (23.292 N, 38.91 E), it was found that the dust was composed largely of hematite, goethite, calcite, dolomite, quartz, chlorite, muscovite, amphibole, epidote and plagioclase. Our results are being compared to, and show similarities to those of Engelbrecht et al. , collected at 15 Middle East sites. Both the mineralogical content and chemical composition of samples bear the signatures of the regional geology. Engelbrecht, J. P., McDonald, E. V., Gillies, J. A., Jayanty, R. K. M., Casuccio, G., and Gertler, A. W., 2009, Characterizing mineral dusts and other aerosols from the Middle East - Part 2: Grab samples and re-suspensions: Inhalation Toxicology, v. 21, p. 327-336.
A randomized trial of the effect of dust control on children's blood lead levels.
Lanphear, B P; Winter, N L; Apetz, L; Eberly, S; Weitzman, M
1996-07-01
Dust control is recommended as one of the cornerstones of controlling childhood lead exposure; however, the effectiveness of dust control has not been demonstrated for children who have low to mild elevations in blood lead (ie, less than 25 micrograms/dL). The objective of this study was to determine whether dust control, as performed by families, had an effect on children's blood lead levels and dust lead levels in children's homes. Randomized, controlled trial. Community-based trial in Rochester, NY. One hundred four children, 12 to 31 months of age at baseline. Families and children were randomized to one of two groups. Families of children in the intervention group received cleaning supplies, information about cleaning areas that are often contaminated with lead, and a cleaning demonstration. Families in the control group received only a brochure about lead poisoning prevention. Baseline measurements of lead in blood, house dust, soil, water, and paint were taken from both groups. Seven months after enrollment, a second blood lead assay was obtained, and lead levels in household dust were measured. The main outcome measures were change in blood lead levels and dust lead levels by treatment group. The median blood lead level of children enrolled in the study was 6.7 micrograms/dL (range, 1.7 to 30.6 micrograms/dL). There was no significant difference in the change of children's blood lead levels or dust lead levels by treatment group. The median change in blood lead levels among children in the intervention group was -0.05 micrograms/dL compared with -0.60 micrograms/dL among those in the control group. There also was no significant difference in the change of dust lead by group assignment, although there was a trend toward a significant difference in the percentage of change in dust lead levels on noncarpeted floors, which was greater among houses in the intervention group. These data suggest that an intervention that consists only of providing cleaning supplies and a brief description of dust control is not effective at reducing blood lead levels among urban children with low to mild elevations in blood lead levels at a 7-month follow-up.
WAGNER, JEFF; GHOSAL, SUTAPA; WHITEHEAD, TODD; METAYER, CATHERINE
2013-01-01
We characterized flame retardant (FR) morphologies and spatial distributions in 7 consumer products and 7 environmental dusts to determine their implications for transfer mechanisms, human exposure, and the reproducibility of gas chromatography-mass spectrometry (GC-MS) dust measurements. We characterized individual particles using scanning electron microscopy / energy dispersive x-ray spectroscopy (SEM/EDS) and Raman micro-spectroscopy (RMS). Samples were screened for the presence of 3 FR constituents (bromine, phosphorous, non-salt chlorine) and 2 metal synergists (antimony and bismuth). Subsequent analyses of select samples by RMS enabled molecular identification of the FR compounds and matrix materials. The consumer products and dust samples possessed FR elemental weight percents of up to 36% and 31%, respectively. We identified 24 FR-containing particles in the dust samples and classified them into 9 types based on morphology and composition. We observed a broad range of morphologies for these FR-containing particles, suggesting FR transfer to dust via multiple mechanisms. We developed an equation to describe the heterogeneity of FR-containing particles in environmental dust samples. The number of individual FR-containing particles expected in a 1-mg dust sample with a FR concentration of 100 ppm ranged from <1 to >1000 particles. The presence of rare, high-concentration bromine particles was correlated with decabromodiphenyl ether concentrations obtained via GC-MS. When FRs are distributed heterogeneously in highly concentrated dust particles, human exposure to FRs may be characterized by high transient exposures interspersed by periods of low exposure, and GC-MS FR concentrations may exhibit large variability in replicate subsamples. Current limitations of this SEM/EDS technique include potential false negatives for volatile and chlorinated FRs and greater quantitation uncertainty for brominated FR in aluminum-rich matrices. PMID:23739093
Toxicity of Lunar Dust in Lungs Assessed by Examining Biomarkers in Exposed Mice
NASA Technical Reports Server (NTRS)
Lam, C.-W.; James, J. T.; Zeidler-Erdely, P. C.; Castranova, V.; Young, S. H.; Quan, C. L.; Khan-Mayberry, N.; Taylor, L. A.
2009-01-01
NASA plans to build an outpost on the Moon for prolonged human habitation and research. The lunar surface is covered by a layer of soil, of which the finest portion is highly reactive dust. NASA has invited NIOSH to collaboratively investigate the toxicity of lunar dust. Dust samples of respirable sizes were aerodynamically isolated from two lunar soil samples of different maturities (cosmic exposure ages) collected during the Apollo 16 mission. The lunar dust samples, titanium dioxide, or quartz, suspended in normal saline or in Survanta (a bovine lung surfactant), were given to groups of 5 mice (C-57 male) by intrapharyngeal aspiration at 1, 0.3, or 0.1 mg/mouse. The mice were euthanized 7 or 30 days later, and their lungs were lavaged to assess the toxicity biomarkers in bronchioalveolar lavage fluids. The acellular fractions were assayed for total proteins, lactate dehydrogenase activities, and cytokines; the cellular portions were assessed for total cell counts and cell differentials. Results from the high-dose groups showed that lunar dust, suspended in saline, was more toxic than TiO 2, but less toxic than quartz. Lunar dust particles aggregate and settle out rapidly in water or saline, but not in Survanta. Lunar dust suspended in Survanta manifested greater toxicity than lunar dust in saline. The increase in toxicity presumably was due to that Survanta gave a better particle dispersion in the lungs. The two lunar dust samples showed similar toxicity. The overall results showed that lunar dust is more toxic than TiO 2 but less toxic than quartz.
Seasonal and occupational trends of five organophosphate pesticides in house dust.
Smith, Marissa N; Workman, Tomomi; McDonald, Katie M; Vredevoogd, Melinda A; Vigoren, Eric M; Griffith, William C; Thompson, Beti; Coronado, Gloria D; Barr, Dana; Faustman, Elaine M
2017-07-01
Since 1998, the University of Washington's Center for Child Environmental Health Risks Research has followed a community-based participatory research strategy in the Lower Yakima Valley of Washington State to assess pesticide exposure among families of Hispanic farmworkers. As a part of this longitudinal study, house dust samples were collected from both farmworker and non-farmworker households, across three agricultural seasons (thinning, harvest and non-spray). The household dust samples were analyzed for five organophosphate pesticides: azinphos-methyl, phosmet, malathion, diazinon, and chlorpyrifos. Organophosphate pesticide levels in house dust were generally reflective of annual use rates and varied by occupational status and agricultural season. Overall, organophosphate pesticide concentrations were higher in the thinning and harvest seasons than in the non-spray season. Azinphos-methyl was found in the highest concentrations across all seasons and occupations. Farmworker house dust had between 5- and 9-fold higher concentrations of azinphos-methyl than non-farmworker house dust. Phosmet was found in 5-7-fold higher concentrations in farmworker house dust relative to non-farmworker house dust. Malathion and chlorpyriphos concentrations in farmworker house dust ranged between 1.8- and 9.8-fold higher than non-farmworker house dust. Diazinon showed a defined seasonal pattern that peaked in the harvest season and did not significantly differ between farmworker and non-farmworker house dust. The observed occupational differences in four out of five of the pesticide residues measured provides evidence supporting an occupational take home pathway, in which workers may bring pesticides home on their skin or clothing. Further, these results demonstrate the ability of dust samples to inform the episodic nature of organophosphate pesticide exposures and the need to collect multiple samples for complete characterization of exposure potential.
Distribution and determinants of mouse allergen exposure in low-income New York City apartments.
Chew, Ginger L; Perzanowski, Matthew S; Miller, Rachel L; Correa, Juan C; Hoepner, Lori A; Jusino, Carlos M; Becker, Mark G; Kinney, Patrick L
2003-01-01
Previous studies of mouse allergens and laboratory-animal-worker-related allergy and asthma suggest that quantifying mouse allergen levels in homes could augment our understanding of inner-city asthma. We hypothesized that levels of mouse allergen in inner-city homes would be related to certain household characteristics. Dust samples were collected from the kitchens and beds of 221 mothers enrolled in a prospective birth cohort study, 92 of African American and 129 of Dominican ethnicity. Samples were analyzed for mouse urinary protein. The geometric mean for kitchen samples was 4.6 micro g/g [95% confidence interval (95% CI), 3.2-6.5] and for bed samples was 0.9 micro g/g (95% CI, 0.8-1.1). The variables associated with mouse allergen levels in the home were frequency of mouse sightings, use of traps or pesticides for mice, presence of holes in ceilings or walls, absence of a cat, and living in a building with fewer than eight floors. Statistically significant neighborhood differences in levels of mouse allergen and report of rodents in the home were also observed. In conclusion, mouse allergen was prevalent among inner-city apartments, and the positive predictive value of self-reported frequent mouse sightings was high (90% for kitchens). However, high levels of mouse allergen were also found in many homes where mothers reported never seeing mice. PMID:12896857
Filter forensics: microbiota recovery from residential HVAC filters.
Maestre, Juan P; Jennings, Wiley; Wylie, Dennis; Horner, Sharon D; Siegel, Jeffrey; Kinney, Kerry A
2018-01-30
Establishing reliable methods for assessing the microbiome within the built environment is critical for understanding the impact of biological exposures on human health. High-throughput DNA sequencing of dust samples provides valuable insights into the microbiome present in human-occupied spaces. However, the effect that different sampling methods have on the microbial community recovered from dust samples is not well understood across sample types. Heating, ventilation, and air conditioning (HVAC) filters hold promise as long-term, spatially integrated, high volume samplers to characterize the airborne microbiome in homes and other climate-controlled spaces. In this study, the effect that dust recovery method (i.e., cut and elution, swabbing, or vacuuming) has on the microbial community structure, membership, and repeatability inferred by Illumina sequencing was evaluated. The results indicate that vacuum samples captured higher quantities of total, bacterial, and fungal DNA than swab or cut samples. Repeated swab and vacuum samples collected from the same filter were less variable than cut samples with respect to both quantitative DNA recovery and bacterial community structure. Vacuum samples captured substantially greater bacterial diversity than the other methods, whereas fungal diversity was similar across all three methods. Vacuum and swab samples of HVAC filter dust were repeatable and generally superior to cut samples. Nevertheless, the contribution of environmental and human sources to the bacterial and fungal communities recovered via each sampling method was generally consistent across the methods investigated. Dust recovery methodologies have been shown to affect the recovery, repeatability, structure, and membership of microbial communities recovered from dust samples in the built environment. The results of this study are directly applicable to indoor microbiota studies utilizing the filter forensics approach. More broadly, this study provides a better understanding of the microbial community variability attributable to sampling methodology and helps inform interpretation of data collected from other types of dust samples collected from indoor environments.
The relationship between gorgonian coral (Cnidaria: Gorgonacea) diseases and African dust storms
Weir-Brush, J. R.; Garrison, V.H.; Smith, G.W.; Shinn, E.A.
2004-01-01
The number of reports of coral diseases has increased throughout the world in the last 20 years. Aspergillosis, which primarily affects Gorgonia ventalina and G. flabellum, is one of the few diseases to be characterized. This disease is caused by Aspergillus sydowii, a terrestrial fungus with a worldwide distribution. Upon infection, colonies may lose tissue, and ultimately, mortality may occur if the infection is not sequestered. The spores of A. sydowii are <5 ??m, small enough to be easily picked up by winds and dispersed over great distances. Aspergillosis is prevalent in the Caribbean, and it appears that this primarily terrestrial fungus has adapted to a marine environment. It has been proposed that dust storms originating in Africa may be one way in which potential coral pathogens are distributed and deposited into the marine environments of the Caribbean. To test the hypothesis that African dust storms transport and deposit pathogens, we collected air samples from both dust storms and periods of nondust in St. John, U.S. Virgin Islands. Because we focused on fungal pathogens and used A. sydowii as a model, we isolated and cultured fungi on various types of media. Fungi including Aspergillus spp. were isolated from air samples taken from dust events and non-dust events. Twenty-three separate cultures and seven genera were isolated from dust event samples whereas eight cultures from five genera were isolated from non-dust air samples. Three isolates from the Virgin Islands dust event samples morphologically identified as Aspergillus spp. produced signs of aspergillosis in seafans, and the original pathogens were re-isolated from those diseased seafans fulfilling Koch's Postulates. This research supports the hypothesis that African dust storms transport across the Atlantic Ocean and deposit potential coral pathogens in the Caribbean.
NASA Astrophysics Data System (ADS)
Wong, B.; Kilthau, W.; Knopf, D. A.
2017-12-01
Immersion freezing is recognized as the most important ice crystal formation process in mixed-phase cloud environments. It is well established that mineral dust species can act as efficient ice nucleating particles. Previous research has focused on determination of the ice nucleation propensity of individual mineral dust species. In this study, the focus is placed on how different mineral dust species such as illite, kaolinite and feldspar, initiate freezing of water droplets when present in internal and external mixtures. The frozen fraction data for single and multicomponent mineral dust droplet mixtures are recorded under identical cooling rates. Additionally, the time dependence of freezing is explored. Externally and internally mixed mineral dust droplet samples are exposed to constant temperatures (isothermal freezing experiments) and frozen fraction data is recorded based on time intervals. Analyses of single and multicomponent mineral dust droplet samples include different stochastic and deterministic models such as the derivation of the heterogeneous ice nucleation rate coefficient (Jhet), the single contact angle (α) description, the α-PDF model, active sites representation, and the deterministic model. Parameter sets derived from freezing data of single component mineral dust samples are evaluated for prediction of cooling rate dependent and isothermal freezing of multicomponent externally or internally mixed mineral dust samples. The atmospheric implications of our findings are discussed.
Bern, A.M.; Lowers, H.A.; Meeker, G.P.; Rosati, J.A.
2009-01-01
The collapse of the World Trade Center Towers on September 11, 2001, sent dust and debris across much of Manhattan and in the surrounding areas. Indoor and outdoor dust samples were collected and characterized by U.S. Geological Survey (USGS) scientists using scanning electron microscopy with energy-dispersive spectrometry (SEM/EDS). From this characterization, the U.S. Environmental Protection Agency and USGS developed a particulate screening method to determine the presence of residual World Trade Center dust in the indoor environment using slag wool as a primary "signature". The method describes a procedure that includes splitting, ashing, and sieving of collected dust. From one split, a 10 mg/mL dust/ isopropanol suspension was prepared and 10-30 ??L aliquots of the suspension placed on an SEM substrate. Analyses were performed using SEM/EDS manual point counting for slag wool fibers. Poisson regression was used to identify some of the sources of uncertainty, which are directly related to the small number of fibers present on each sample stub. Preliminary results indicate that the procedure is promising for screening urban background dust for the presence of WTC dust. Consistent sample preparation of reference materials and samples must be performed by each laboratory wishing to use this method to obtain meaningful and accurate results. ?? 2009 American Chemical Society.
A DUST-SETTLING CHAMBER FOR SAMPLING-INSTRUMENT COMPARISON STUDIES
Introduction: Few methods exist that can evenly and reproducibly deposit dusts onto surfaces for surface-sampling methodological studies. A dust-deposition chamber was designed for that purpose.
Methods: A 1-m3 Rochester-type chamber was modified to produce high airborne d...
Identification of dust storm origin in South -West of Iran.
Broomandi, Parya; Dabir, Bahram; Bonakdarpour, Babak; Rashidi, Yousef
2017-01-01
Deserts are the main sources of emitted dust, and are highly responsive to wind erosion. Low content of soil moisture and lack of vegetation cover lead to fine particle's release. One of the semi-arid bare lands in Iran, located in the South-West of Iran in Khoozestan province, was selected to investigate Sand and Dust storm potential. This paper focused on the metrological parameters of the sampling site, their changes and the relationship between these changes and dust storm occurrence, estimation of Reconaissance Drought Index, the Atterberg limits of soil samples and their relation with soil erosion ability, the chemical composition, size distribution of soil and airborne dust samples, and estimation of vertical mass flux by COMSALT through considering the effect of saffman force and interparticle cohesion forces during warm period (April-September) in 2010. The chemical compositions are measured with X-ray fluorescence, Atomic absorption spectrophotometer and X-ray diffraction. The particle size distribution analysis was conducted by using Laser particle size and sieve techniques. There was a strong negative correlation between dust storm occurrence and annual and seasonal rainfall and relative humidity. Positive strong correlation between annual and seasonal maximum temperature and dust storm frequency was seen. Estimation of RDI st in the studied period showed an extremely dry condition. Using the results of particle size distribution and soil consistency, the weak structure of soil was represented. X-ray diffraction analyses of soil and dust samples showed that soil mineralogy was dominated mainly by Quartz and calcite. X-ray fluorescence analyses of samples indicated that the most important major oxide compositions of the soil and airborne dust samples were SiO 2 , Al 2 O 3 , CaO, MgO, Na 2 O, and Fe 2 O 3 , demonstrating similar percentages for soil and dust samples. Estimation of Enrichment Factors for all studied trace elements in soil samples showed Br, Cl, Mo, S, Zn, and Hg with EF values higher than 10. The findings, showed the possible correlation between the degree of anthropogenic soil pollutants, and the remains of Iraq-Iran war. The results expressed sand and dust storm emission potential in this area, was illustrated with measured vertical mass fluxes by COMSALT.
Cherneva, P; Lukanova, R
1994-01-01
The variability of the dust concentration in time and space, as well as the change of worker's place during the working process, define the necessity of introducing personal sampling in the hygiene control practice. However, the laboratory equipment with personal devices is still not sufficient. The aim of this work is to assess the dust exposure of the basic professional groups from the ore- and coal production in Bulgaria by personal sampling in comparative studies of the static ambient sampling used up to now. 63 full-shift investigations of the dust factor were performed on professional groups of miners of the polymetal and coal pits by static ambient devices-[Hygitest production] and personal [from firms "Casella", "Strolein" and "Gilian"] devices, after standardized methods. The results are data processed-by means of logarithmic normal distribution of the relation of the respirable dust concentrations, determined personally and by static ambient sampling. The limits of variation of this correlation are from 0.5 to 4.1 at average geometric value -0.95 and standard geometric deviation-1.8 i.e. both types of sampling are intersubstitutional for the examined groups and sites, as in the underground ores the professional risk of respirable dust is underestimated up to 4 times at static ambient sampling.
Stardust Sample Collection at Wild 2 and Its Preliminary Examination
NASA Technical Reports Server (NTRS)
Tsou, P.; Brownlee, D. E.; Hoerz, F.; Newburn, R. L.; Sandford, S. A.; Sekanina, Z.; Zolensky, M. E.
2004-01-01
The primary objective of STARDUST is to collect coma samples from 81P/Wild 2. This was made on January 2, 2004. Before the encounter three significant model predictions existed for the number and size of samples to be captured. Three investigations during the Wild 2 encounter (Dust Flux Monitor, Comet and Interstellar Dust Analyzer and Dynamic Science) made in situ measurements of the dust. Spectacular images were captured of the Wild 2 nucleus and dust jets. This abstract compares the model predictions with the in situ measurements and Wild 2 images and assesses the likely samples to be returned for analysis on January 15, 2006. To give some lead time for sample analysts to prepare for the analyses of the returned samples, the organization of the Preliminary Examination is presented.
Evaluation of impermeable covers for bedding in patients with allergic rhinitis.
Terreehorst, Ingrid; Hak, Eelko; Oosting, Albert J; Tempels-Pavlica, Zana; de Monchy, Jan G R; Bruijnzeel-Koomen, Carla A F M; Aalberse, Rob C; Gerth van Wijk, Roy
2003-07-17
Encasing bedding in impermeable covers reduces exposure to house-dust mites, but the clinical benefit of this intervention as part of mite-avoidance measures for patients with allergic rhinitis is not known. We performed a multicenter, randomized, placebo-controlled trial of one year of use of impermeable bedding covers in the bedrooms of patients with rhinitis who were sensitized to house-dust mites to determine the effects on the signs and symptoms of disease. Three participating university medical centers enrolled 279 patients with allergic rhinitis who were randomly assigned to receive impermeable or non-impermeable (control) covers for their mattress, pillow, and duvet or blanket. At the start of the study, all participants received information on general allergen-avoidance measures. The severity of rhinitis was measured on a rhinitis-specific visual-analogue scale and by means of a daily symptom score and nasal allergen provocation testing. We also measured the concentrations of Dermatophagoides pteronyssinus (Der p1) and D. farinae (Der f1) in dust from patients' mattresses, bedroom floors, and living-room floors at base line and after 12 months as a measure of the efficacy of the intervention. A total of 232 patients completed the study. There was a significant reduction in Der p1 and Der f1 concentrations in the mattresses of the impermeable-cover group, whereas there was no significant reduction in the control group. However, there was no significant effect on the clinical outcome measures. Analyses of subgroups defined according to age, level of exposure, type and severity of sensitization, or characteristics of the patient's home had similar results. Mite-proof bedding covers, as part of a structured allergy-control program, reduced the level of exposure to mite allergens. Despite the success of the intervention, this single avoidance measure did not lead to a significant improvement of clinical symptoms in patients with allergic rhinitis. Copyright 2003 Massachusetts Medical Society
Investigating Mars: Tithonium Chasma
2018-02-07
This VIS image shows part of the floor of Tithonium Chasma. Eroded materials cover most of the image. The initial formation of layered floor deposits was possibly created of air fall of dust, sand, and volcanic materials and water lain materials. The weathering of these deposits is probably by the wind. The bottom part of the image has complex, hummocky material, probably very old landslide deposits. At the top of the image is a large mound of material that has been eroded mainly by wind action. The overlapping of these surfaces indicates a long history of modication of Tithonium Chasma. Tithonium Chasma is at the western end of Valles Marineris. Valles Marineris is over 4000 kilometers long, wider than the United States. Tithonium Chasma is almost 810 kilometers long (499 miles), 50 kilometers wide and over 6 kilometers deep. In comparison, the Grand Canyon in Arizona is about 175 kilometers long, 30 kilometers wide, and only 2 kilometers deep. The canyons of Valles Marineris were formed by extensive fracturing and pulling apart of the crust during the uplift of the vast Tharsis plateau. Landslides have enlarged the canyon walls and created deposits on the canyon floor. Weathering of the surface and influx of dust and sand have modified the canyon floor, both creating and modifying layered materials. The Odyssey spacecraft has spent over 15 years in orbit around Mars, circling the planet more than 71,000 times. It holds the record for longest working spacecraft at Mars. THEMIS, the IR/VIS camera system, has collected data for the entire mission and provides images covering all seasons and lighting conditions. Over the years many features of interest have received repeated imaging, building up a suite of images covering the entire feature. From the deepest chasma to the tallest volcano, individual dunes inside craters and dune fields that encircle the north pole, channels carved by water and lava, and a variety of other feature, THEMIS has imaged them all. For the next several months the image of the day will focus on the Tharsis volcanoes, the various chasmata of Valles Marineris, and the major dunes fields. We hope you enjoy these images! Orbit Number: 3936 Latitude: -5.06026 Longitude: 271.813 Instrument: VIS Captured: 2002-11-03 13:15 https://photojournal.jpl.nasa.gov/catalog/PIA22269
Comparison of comet 81P/Wild 2 dust with interplanetary dust from comets.
Ishii, Hope A; Bradley, John P; Dai, Zu Rong; Chi, Miaofang; Kearsley, Anton T; Burchell, Mark J; Browning, Nigel D; Molster, Frank
2008-01-25
The Stardust mission returned the first sample of a known outer solar system body, comet 81P/Wild 2, to Earth. The sample was expected to resemble chondritic porous interplanetary dust particles because many, and possibly all, such particles are derived from comets. Here, we report that the most abundant and most recognizable silicate materials in chondritic porous interplanetary dust particles appear to be absent from the returned sample, indicating that indigenous outer nebula material is probably rare in 81P/Wild 2. Instead, the sample resembles chondritic meteorites from the asteroid belt, composed mostly of inner solar nebula materials. This surprising finding emphasizes the petrogenetic continuum between comets and asteroids and elevates the astrophysical importance of stratospheric chondritic porous interplanetary dust particles as a precious source of the most cosmically primitive astromaterials.
Reconciling PM10 analyses by different sampling methods for Iron King Mine tailings dust.
Li, Xu; Félix, Omar I; Gonzales, Patricia; Sáez, Avelino Eduardo; Ela, Wendell P
2016-03-01
The overall project objective at the Iron King Mine Superfund site is to determine the level and potential risk associated with heavy metal exposure of the proximate population emanating from the site's tailings pile. To provide sufficient size-fractioned dust for multi-discipline research studies, a dust generator was built and is now being used to generate size-fractioned dust samples for toxicity investigations using in vitro cell culture and animal exposure experiments as well as studies on geochemical characterization and bioassay solubilization with simulated lung and gastric fluid extractants. The objective of this study is to provide a robust method for source identification by comparing the tailing sample produced by dust generator and that collected by MOUDI sampler. As and Pb concentrations of the PM10 fraction in the MOUDI sample were much lower than in tailing samples produced by the dust generator, indicating a dilution of Iron King tailing dust by dust from other sources. For source apportionment purposes, single element concentration method was used based on the assumption that the PM10 fraction comes from a background source plus the Iron King tailing source. The method's conclusion that nearly all arsenic and lead in the PM10 dust fraction originated from the tailings substantiates our previous Pb and Sr isotope study conclusion. As and Pb showed a similar mass fraction from Iron King for all sites suggesting that As and Pb have the same major emission source. Further validation of this simple source apportionment method is needed based on other elements and sites.
Characterization of aerosolized bacteria and fungi from desert dust events in Mali, West Africa
Kellogg, C.A.; Griffin, Dale W.; Garrison, V.H.; Peak, K.K.; Royall, N.; Smith, R.R.; Shinn, E.A.
2004-01-01
Millions of metric tons of African desert dust blow across the Atlantic Ocean each year, blanketing the Caribbean and southeastern United States. Previous work in the Caribbean has shown that atmospheric samples collected during dust events contain living microbes, including plant and opportunistic human pathogens. To better understand the potential downwind public health and ecosystem effects of the dust microbes, it is important to characterize the source population. We describe 19 genera of bacteria and 3 genera of fungi isolated from air samples collected in Mali, a known source region for dust storms, and over which large dust storms travel.
Mite and pet allergen exposure in hotels in Uberlândia, Midwestern Brazil.
Simplício, E C; Silva, D A O; Braga, I A; Sopelete, M C; Sung, S J; Taketomi, E A
2007-08-01
Mite allergens are involved in airway sensitization and allergic diseases. We evaluated the exposure to house dust-mite (Der p 1 and Der f 1) and pet (Fel d 1 and Can f 1) allergens in hotels in Uberlândia, Midwestern Brazil. A total of 140 dust samples were collected from bedding (n = 98) and carpet (n = 42) of bedrooms in 20 hotels enrolled for this study. Geometric mean (GM) levels of Der f 1 (11.30 microg/g of dust; 95% CI: 8.34-15.30 microg/g) were significantly higher than Der p 1 (0.15 microg/g of dust; 95% CI: 0.13-0.18 microg/g) in bedding dust samples (P < 0.001), regardless of the hotel classes. Der f 1 levels were significantly higher in bedding (11.30 microg/g of dust; 95% CI: 8.34-15.30 microg/g) than carpet (6.32 microg/g of dust; 95% CI: 4.31-9.26 microg/g) dust samples (P < 0.05). High levels of Der f 1 (>10 microg/g of dust) were found in 58%, 76%, and 69% of dust samples from Simple, Economical, and Tourist/Superior hotels, respectively, while GM levels of Fel d 1 (0.11 microg/g of dust; 95% CI: 0.09-0.14 microg/g) and Can f 1 (0.30 microg/g of dust; 95% CI: 0.20-0.44 microg/g) were relatively low. These results indicate that Der f 1 is the predominant allergen in hotels in Uberlândia, especially in bedding dust samples, regardless of the hotel classes and could represent an important risk factor for exacerbation of allergic symptoms in previously mite-sensitized guests. Mites and pets are important sources of indoor allergens. Most people spend the greatest part of their time indoors. Hotels can constitute an important allergen reservoir of the indoor environment and could represent an important risk for exacerbation of allergic symptoms in previously sensitized guests. Thus, hotels should also be included for planning indoor allergen avoidance as part of a global management strategy, especially in patients with respiratory allergy.
Microbial secondary metabolites in homes in association with moisture damage and asthma.
Kirjavainen, P V; Täubel, M; Karvonen, A M; Sulyok, M; Tiittanen, P; Krska, R; Hyvärinen, A; Pekkanen, J
2016-06-01
We aimed to characterize the presence of microbial secondary metabolites in homes and their association with moisture damage, mold, and asthma development. Living room floor dust was analyzed by LC-MS/MS for 333 secondary metabolites from 93 homes of 1-year-old children. Moisture damage was present in 15 living rooms. At 6 years, 8 children had active and 15 lifetime doctor-diagnosed asthma. The median number of different metabolites per house was 17 (range 8-29) and median sum load 65 (4-865) ng/m(2) . Overall 42 different metabolites were detected. The number of metabolites present tended to be higher in homes with mold odor or moisture damage. The higher sum loads and number of metabolites with loads over 10 ng/m(2) were associated with lower prevalence of active asthma at 6 years (aOR 0.06 (95% CI <0.001-0.96) and 0.05 (<0.001-0.56), respectively). None of the individual metabolites, which presence tended (P < 0.2) to be increased by moisture damage or mold, were associated with increased risk of asthma. Microbial secondary metabolites are ubiquitously present in home floor dust. Moisture damage and mold tend to increase their numbers and amount. There was no evidence indicating that the secondary metabolites determined would explain the association between moisture damage, mold, and the development of asthma. © 2015 The Authors. Indoor Air published by John Wiley & Sons Ltd.
Airway toxicity of house dust and its fungal composition.
Piecková, Elena; Wilkins, Ken
2004-01-01
House dust is an important source of different toxic metabolites as well as allergens, including those of fungal origin, in the indoor environment. A bio-assay employing 1-day-old chick tracheas was used to characterize airway effects of 2-butanone and dimethylsulphoxide (Me2SO) extracts of 23 dust samples collected from water damaged (13) and control (10) Danish schools. Direct microscopical analysis of samples, followed by cultivation on dichloran 18 % glycerol agar at 25 degrees C for 10 days to establish their mycoflora, was performed. The in vitro ciliostatic potential of the chloroform-extractable endo- and exometabolites of 41 representative fungal isolates was determined. Nine dust extracts in 2-butanone (2 from damp rooms) or 10 (6) in Me(2)SO showed some ciliostatic activity in the 3-days' experiment. Fungal composition of dust from buildings with leakage was almost identical with that from undamaged houses, as well as the fungal colony counts from the damp schools and the control samples. Aspergillus spp. were prevalent in the samples - 31 or 40 % of all fungi, followed by Penicillium spp. and Cladosporium cladosporioides. Alternaria spp., Chaetomium spp., Mucor spp., Mycelia sterilia, Paecilomyces variotii, Rhizopus sp., Ulocladium sp. and yeasts were each isolated in less than 8 % of the fungal content. No Aspergillus flavus isolate (8 in total) was aflatoxigenic,em>in vitro. Alternaria spp., Aspergillus spp., Botrytis cinerea, Penicillium spp., C. cladosporioides, Chaetomium spp. and Ulocladium sp.; in total, 88 % of all fungi tested, produced ciliostatically active metabolites. These toxigenic strains were also present in 4 dust samples from controls and 5 dust samples from water damaged buildings. Extracts of these dust samples were also toxic in bioassay. There were bio-detectable concentrations (10-20 microg of extracts/ml of the organ culture medium) of toxic compounds in house dust. Contribution of fungal metabolites to its toxic effect should be studied further.
Common Warm Dust Temperatures Around Main Sequence Stars
NASA Technical Reports Server (NTRS)
Morales, Farisa; Rieke, George; Werner, Michael; Stapelfeldt, Karl; Bryden, Geoffrey; Su, Kate
2011-01-01
We compare the properties of warm dust emission from a sample of main-sequence A-type stars (B8-A7) to those of dust around solar-type stars (F5-KO) with similar Spitzer Space Telescope Infrared Spectrograph/MIPS data and similar ages. Both samples include stars with sources with infrared spectral energy distributions that show evidence of multiple components. Over the range of stellar types considered, we obtain nearly the same characteristic dust temperatures (∼ 190 K and ∼60 K for the inner and outer dust components, respectively)-slightly above the ice evaporation temperature for the inner belts. The warm inner dust temperature is readily explained if populations of small grains are being released by sublimation of ice from icy planetesimals. Evaporation of low-eccentricity icy bodies at ∼ 150 K can deposit particles into an inner/warm belt, where the small grains are heated to dust Temperatures of -190 K. Alternatively, enhanced collisional processing of an asteroid belt-like system of parent planetesimals just interior to the snow line may account for the observed uniformity in dust temperature. The similarity in temperature of the warmer dust across our B8-KO stellar sample strongly suggests that dust-producing planetesimals are not found at similar radial locations around all stars, but that dust production is favored at a characteristic temperature horizon.
Lewis, R G; Fortune, C R; Blanchard, F T; Camann, D E
2001-03-01
Post-application temporal and spatial distributions of two organophosphorus pesticides, diazinon (O,O-diethyl O-[6-methyl-2-(1-methylethyl)-4-pyrimidinyl] phosphorothioate, CAS No. 333-41-5) and chlorpyrifos [O,O-diethyl-O-(2-isopropyl-6-methyl-4-pyrimidinyl) phosphorothioate, CAS No. 2921-88-2], were monitored after homeowner applications for indoor and outdoor insect control. Samples of indoor air, vacuumable carpet dust, carpet dislodgeable residues, deposits on bare floors, table tops and dinnerware, surrogate food, and residues on children's hands and toys were taken before and up to 12 days after treatments in the family room, kitchen, and child's bedroom. Results from the study demonstrate the nature and magnitude of translocation of pesticides from the areas of application to surfaces accessible for human contact and permit comparisons of potential exposures via respiration and dermal contact/oral ingestion. Potential indoor inhalation exposures were estimated to be as high as 0.5 microg/kg/day for diazinon applied indoors and 0.05 microg/kg/day for chlorpyrifos applied to the outside perimeter of the house. While ingestion of carpet dust at the rate of 100 microg/day would have added a maximum of only approximately 0.01 microg/kg/day to the daily dose, residues found on the children's hands suggest that repeated mouthing could have contributed as much as 1-1.5 microg/kg/day. These estimates are below the U.S. Environmental Protection Agency (EPA) reference dose for chlorpyrifos, but exceed those for diazinon.
Martian Dust Devils: 2 Mars Years of MGS MOC Observations
NASA Astrophysics Data System (ADS)
Cantor, B. A.; Edgett, K. S.
2002-12-01
Mars Global Surveyor (MGS) Mars Orbiter Camera (MOC) wide and narrow angle images have captured more than 1000 active dust devils over 2 Mars years. In the most recent Mars year, we repeatedly imaged (and are continuing to image) several areas to monitor dust devil occurrence. Some Mars dust devils are as small as a few to 10s of meters across, others are 100s of meters across and over 6 km high. Each Martian hemisphere has a "dust devil season" that generally follows the subsolar latitude. An exception is NW Amazonis, which has frequent, large dust devils throughout northern spring and summer (probably every afternoon; observations are acquired 2-3 times a week). The Amazonis and other MOC observations show no evidence that dust devils cause, lead to, or have a systematic relationship with dust storms. However, dust devils sometimes do occur near small, localized storms; and one specific relation occurred during the onset of the global dust events of 2001: slightly elevated levels of atmospheric dust (an optically thin cloud) triggered a very short period of dust devil activity in NW Amazonis in early northern autumn. The redistribution of dust by the 2001 global events may have also affected subsequent spring and summer dust devil activity in Hellas, where considerably fewer dust devils occurred in 2001-2002 than 1999-2000. In SW Syria, frequent, large dust devils occurred after the 2001 global events and persisted through southern summer. While dust devils have no specific relation to dust storms, they might play a role in the seasonal "wave of darkening" at middle and high latitudes by removing or disrupting thin veneers of dust. Dust devils have been observed to create thin, filamentary streaks. Some streaks are darker than their surroundings, while others are lighter. Some dust devils do not create streaks. At mid-latitudes, surfaces darken in spring as 100s of crisscrossing streaks form on widely-varied terrain. Some rare streaks exhibit cycloidal patterns similar to those created on Earth by tornadoes with multiple sub-vortices. The streaks occur at nearly all latitudes and elevations, from north polar dunes to the south polar layered terrain, from the summit of Olympus Mons to the floor of Hellas. During "dust devil season" at a given latitude, tremendous changes in streak patterns occur in periods as short as 1 month. These observations, along with repeated imaging in NW Amazonis and SW Syria, provide some idea of the frequency of dust devils. Uncertain is whether dust devils are responsible for all thin, filamentary streaks: while active vortices have been seen creating the plethora of streaks at southern mid-latitudes, none have been observed on the northern plains, despite observation of similar streak patterns. Perhaps northern plains dust devils occur at a different time of day relative to the MGS 1400 LT orbit, or perhaps dust devils did not form them. We monitored removal of dust from surfaces after the 2001 global dust events in several locations. Of particular interest was western Syrtis Major, which had brightened considerably after the 2001 storms. We observed this area for several months while very little change occurred. Finally, in January 2002, the surface was swept clean of most of its 2001 veneer of dust in a period of about 1 week. Dust devils played no role in this process; instead, regional surface winds were responsible.
Combustibility Determination for Cotton Gin Dust and Almond Huller Dust.
Hughs, Sidney E; Wakelyn, Phillip J
2017-04-26
It has been documented that some dusts generated while processing agricultural products, such as grain and sugar, can constitute combustible dust hazards. After a catastrophic dust explosion in a sugar refinery in 2008, the Occupational Safety and Health Administration (OSHA) initiated action to develop a mandatory standard to comprehensively address the fire and explosion hazards of combustible dusts. Cotton fiber and related materials from cotton ginning, in loose form, can support smoldering combustion if ignited by an outside source. However, dust fires and other more hazardous events, such as dust explosions, are unknown in the cotton ginning industry. Dust material that accumulates inside cotton gins and almond huller plants during normal processing was collected for testing to determine combustibility. Cotton gin dust is composed of greater than 50% inert inorganic mineral dust (ash content), while almond huller dust is composed of at least 7% inert inorganic material. Inorganic mineral dust is not a combustible dust. The collected samples of cotton gin dust and almond huller dust were sieved to a known particle size range for testing to determine combustibility potential. Combustibility testing was conducted on the cotton gin dust and almond huller dust samples using the UN test for combustibility suggested in NFPA 652.. This testing indicated that neither the cotton gin dust nor the almond huller dust should be considered combustible dusts (i.e., not a Division 4.1 flammable hazard per 49 CFR 173.124). Copyright© by the American Society of Agricultural Engineers.
Dust Concentrations and Composition During African Dust Incursions in the Caribbean Region
NASA Astrophysics Data System (ADS)
Mayol-Bracero, O. L.; Santos-Figueroa, G.; Morales-Garcia, F.
2016-12-01
The World Health Organization (WHO) indicates that exposure to PM10 concentrations higher than 50 µg/m³ 24-hour mean in both developed and developing countries could have an adverse impact on public health. Recent studies showed that in the Caribbean region the PM10 concentrations often exceed the WHO guidelines for PM10. These exceedances are largely driven by the presence of African Dust particles that reach the Caribbean region every year during the summer months. These dust particles also influence the Earth's radiative budget directly by scattering solar radiation in the atmosphere and indirectly by affecting cloud formation and, thus, cloud albedo. In order to have a better understanding of the impacts of African Dust on public health and climate, we determine the concentration of dust particles, the carbonaceous fraction (total, elemental and organic carbon: TC, EC, and OC) and water-soluble ions (e.g., Na+, Cl-, Ca+2, NH4+, SO4-2) of aerosol samples in the presence and absence of African Dust. Samples were collected using a Hi-Vol and Stacked-Filter Units for the sampling of total suspended particles (TSP) at two stations in Puerto Rico: a marine site located at Cabezas de San Juan (CSJ) Nature Reserve, in Fajardo, and an urban site located at the University of Puerto Rico, in San Juan. The presence of African Dust was supported with Saharan Air Layer (SAL) imagery and with the results from the air mass backward trajectories calculated with the NOAA Hybrid Single Particle Lagrangian Integrated Trajectory Model (HYSPLIT). Preliminary results showed that the total mass concentration of aerosols obtained at the urban site is about two times that at the marine site for SFU samples during African Dust incursions. The average dust concentration obtained at CSJ for Hi Vol samples was 22 µg/m³ during the summer 2015. African Dust concentrations, TC, EC, OC, and ionic speciation results for the marine and urban sites will be presented at the conference.
NASA Technical Reports Server (NTRS)
Harrington, A. D.; McCubbin, F. M.
2018-01-01
Manned missions to the Moon highlight a major hazard for future human exploration of the Moon and beyond: surface dust. Not only did the dust cause mechanical and structural integrity issues with the suits, the dust 'storm' generated upon reentrance into the crew cabin caused "lunar hay fever" and "almost blindness" . It was further reported that the allergic response to the dust worsened with each exposure. Due to the prevalence of these high exposures, the Human Research Roadmap developed by NASA identifies the Risk of Adverse Health and Performance Effects of Celestial Dust Exposure as an area of concern. Extended human exploration will further increase the probability of inadvertent and repeated exposures to celestial dusts. Going forward, hazard assessments of celestial dusts will be determined through sample return efforts prior to astronaut deployment.
MOHAMED, Sabrein H.; EL-ANSARY, Aida L.; EL-AZIZ, Eman M. Abd
2017-01-01
Crystalline free silica is considered as a lung carcinogen and the occupational exposure to its dust is a health hazard to workers employed in industries that involve ores of mineral dust. In Egypt, thousands of people work under conditions of silica dust exposure exceeding the occupational exposure limit, as a result the monitoring of this occupational exposure to crystalline silica dust is required by government legislation. The assessment of the later is a multi-phase process, depend on workplace measurements, quantitative analyses of samples, and comparison of results with the permissible limits. This study aims to investigate occupational exposure to crystalline silica dust at 22 factories in Egypt with different industrial activities like stone cutting, glass making, ceramic, and sand blasting. Dust samples were collected from work sites at the breathing zone using a personal sampling pump and a size-selective cyclone and analyzed using FTIR. The sampling period was 60–120 min. The results show that the exposure at each of the industrial sectors is very much higher than the current national and international limits, and that lead to a great risk of lung cancer and mortality to workers. PMID:29199263
Spatial Distribution of Elemental Concentrations in Street Dust of Hanoi, Vietnam.
Phi, Thai Ha; Chinh, Pham Minh; Hung, Nguyen The; Ly, Luong Thi Mai; Thai, Phong K
2017-02-01
Street dust samples were collected at 163 locations across four different zones of Hanoi, Vietnam, covering different traffic and population densities. Samples were sieved into three fractions of different particle sizes and analyzed for elemental concentrations (K, Ca, Mn, Fe, Zn, Pb) using an X-ray fluorescence (XRF) instrument. The metal concentrations in street dust were compared among different sampling zones and with samples from background to evaluate the degree of pollution. The smallest size particle fraction (diameter <75 μm) contained higher concentrations of metals than the coarser ones (diameters = 75-180 and >180 μm). While concentrations of metals like Ca and Fe are spatially similar, concentrations of Pb and Zn in street dust varied between different zones, with the highest concentrations observed in dust from the downtown area, and lowest levels in the new suburb areas. Overall, compared to studies from cities in other countries, the mean concentration of Pb in street dust in Hanoi was relatively low, suggesting a lower risk to human health due to inhalation or ingestion of Pb-containing dust particles than in cities where Pb concentrations were several times higher.
Toxicity of Lunar Dust in Lungs Assessed by Examining Biomarkers in Exposed Mice
NASA Technical Reports Server (NTRS)
Lam, C.-W.; James, J. T.; Zeidler-Erdely, P. C.; Castranova, V.; Young, S. H.; Quan, C. L.; Khan-Mayberry, N.; Taylor, L. A.
2010-01-01
NASA is contemplating to build an outpost on the Moon for prolonged human habitation and research. The lunar surface is covered by a layer of soil, of which the finest portion is highly reactive dust. Dust samples of respirable sizes were aerodynamically isolated from two lunar soil samples of different maturities (cosmic exposure ages) collected during the Apollo 16 mission. The lunar dust samples, TiO2, or quartz, suspended in normal saline were given to groups of 5 C57 male mice by intrapharyngeal aspiration at 0. 1, 0.3, or 1.0 mg/mouse. Because lunar dust aggregates rapidly in aqueous media, some tests were conducted with dusts suspended in Survanta/saline (1:1). The mice were euthanized 7 or 30 days later, and their lungs were lavaged to assess the presence of toxicity biomarkers in bronchioalveolar lavage fluids. The overall results showed that the two lunar dust samples were similar in toxicity, they were more toxic than T102 , but less toxic than quartz. This preliminary study is a part of the large study to obtain data for setting exposure limits for astronauts living on the Moon
An inhibition enzyme-linked immunosorbent assay (ELISA) was used to determine polychlorinated biphenyls (PCBs) in house dust and soil. Soil and house dust samples were analyzed for PCB by both gas chromatography/electron capture detection (GC/ECD) and ELISA methods. A correlati...
An efficient and reliable analytical method was developed for the sensitive and selective quantification of pyrethroid pesticides (PYRs) in house dust samples. The method is based on selective pressurized liquid extraction (SPLE) of the dust-bound PYRs into dichloromethane (DCM) wi...
Do Carpets Impair Indoor Air Quality and Cause Adverse Health Outcomes: A Review.
Becher, Rune; Øvrevik, Johan; Schwarze, Per E; Nilsen, Steinar; Hongslo, Jan K; Bakke, Jan Vilhelm
2018-01-23
Several earlier studies have shown the presence of more dust and allergens in carpets compared with non-carpeted floors. At the same time, adverse effects of carpeted floors on perceived indoor air quality as well as worsening of symptoms in individuals with asthma and allergies were reported. Avoiding extensive carpet use in offices, schools, kindergartens and bedrooms has therefore been recommended by several health authorities. More recently, carpet producers have argued that former assessments were obsolete and that modern rugs are unproblematic, even for those with asthma and allergies. To investigate whether the recommendation to be cautious with the use of carpets is still valid, or whether there are new data supporting that carpet flooring do not present a problem for indoor air quality and health, we have reviewed the literature on this matter. We have not found updated peer reviewed evidence that carpeted floor is unproblematic for the indoor environment. On the contrary, also more recent data support that carpets may act as a repository for pollutants which may become resuspended upon activity in the carpeted area. Also, the use of carpets is still linked to perception of reduced indoor air quality as well as adverse health effects as previously reported. To our knowledge, there are no publications that report on deposition of pollutants and adverse health outcomes associated with modern rugs. However, due to the three-dimensional structure of carpets, any carpet will to some extent act like a sink. Thus, continued caution should still be exercised when considering the use of wall-to-wall carpeted floors in schools, kindergartens and offices, as well as in children's bedrooms unless special needs indicate that carpets are preferable.
Do Carpets Impair Indoor Air Quality and Cause Adverse Health Outcomes: A Review
Becher, Rune; Øvrevik, Johan; Schwarze, Per E.; Nilsen, Steinar; Hongslo, Jan K.; Bakke, Jan Vilhelm
2018-01-01
Several earlier studies have shown the presence of more dust and allergens in carpets compared with non-carpeted floors. At the same time, adverse effects of carpeted floors on perceived indoor air quality as well as worsening of symptoms in individuals with asthma and allergies were reported. Avoiding extensive carpet use in offices, schools, kindergartens and bedrooms has therefore been recommended by several health authorities. More recently, carpet producers have argued that former assessments were obsolete and that modern rugs are unproblematic, even for those with asthma and allergies. To investigate whether the recommendation to be cautious with the use of carpets is still valid, or whether there are new data supporting that carpet flooring do not present a problem for indoor air quality and health, we have reviewed the literature on this matter. We have not found updated peer reviewed evidence that carpeted floor is unproblematic for the indoor environment. On the contrary, also more recent data support that carpets may act as a repository for pollutants which may become resuspended upon activity in the carpeted area. Also, the use of carpets is still linked to perception of reduced indoor air quality as well as adverse health effects as previously reported. To our knowledge, there are no publications that report on deposition of pollutants and adverse health outcomes associated with modern rugs. However, due to the three-dimensional structure of carpets, any carpet will to some extent act like a sink. Thus, continued caution should still be exercised when considering the use of wall-to-wall carpeted floors in schools, kindergartens and offices, as well as in children’s bedrooms unless special needs indicate that carpets are preferable. PMID:29360764
An, Jae-Yoon; Kim, Sumin; Kim, Hyun-Joong
2011-03-15
Formaldehyde was measured with a desiccator, a 20 L chamber and the FLEC method. The formaldehyde emission rate from laminate was the highest at 32 °C using the desiccator, which then decreased with time. The formaldehyde emission using the 20 L small chamber and FLEC showed a similar tendency. There was a strong correlation between the formaldehyde and total volatile organic compounds (TVOCs) with both types of floorings using the two different methods. The formaldehyde emission rate and TVOC results were higher when tested using the FLEC method than with the 20 L small chamber method. The emission rate was affected by the joint edge length in laminate flooring. Toluene, ethylbenzene and xylene were the main VOCs emitted from laminate flooring, and there were more unidentified VOCs emitted than identified VOCs. The samples heated with a floor heating system emitted more formaldehyde than those heated using an air circulation system due to the temperature difference between the bottom panel and flooring. The TVOC emission level of the samples was higher when an air circulation system was used than when a floor heating system was used due to the high ventilation rate. Copyright © 2010 Elsevier B.V. All rights reserved.
30 CFR 90.202 - Certified person; sampling.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Certified person; sampling. 90.202 Section 90... Sampling Procedures § 90.202 Certified person; sampling. (a) The respirable dust sampling required by this... on sampling of respirable coal mine dust. (c) A person may be temporarily certified by MSHA to take...
30 CFR 71.202 - Certified person; sampling.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Certified person; sampling. 71.202 Section 71... Sampling Procedures § 71.202 Certified person; sampling. (a) The respirable dust sampling required by this... on sampling of respirable coal mine dust. (c) A person may be temporarily certified by MSHA to take...
30 CFR 71.202 - Certified person; sampling.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Certified person; sampling. 71.202 Section 71... Sampling Procedures § 71.202 Certified person; sampling. (a) The respirable dust sampling required by this... on sampling of respirable coal mine dust. (c) A person may be temporarily certified by MSHA to take...
30 CFR 90.202 - Certified person; sampling.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Certified person; sampling. 90.202 Section 90... Sampling Procedures § 90.202 Certified person; sampling. (a) The respirable dust sampling required by this... on sampling of respirable coal mine dust. (c) A person may be temporarily certified by MSHA to take...
A search for polycyclic aromatic hydrocarbons over the Martian South Polar Residual Cap
NASA Astrophysics Data System (ADS)
Campbell, J. D.; Sidiropoulos, P.; Muller, J.-P.
2018-07-01
We present our research on compositional mapping of the Martian South Polar Residual Cap (SPRC), especially the detection of organic signatures within the dust content of the ice, based on hyperspectral data analysis. The SPRC is the main region of interest for this investigation, because of the unique CO2 ice sublimation features that cover the surface. These flat floored, circular depressions are highly dynamic, and we infer frequently expose dust particles previously trapped within the ice during the wintertime. Here we identify suitable regions for potential dust exposure on the SPRC, and utilise data from the Compact Reconnaissance Imaging Spectrometer for Mars (CRISM) on board NASA's Mars Reconnaissance Orbiter (MRO) satellite to examine infrared spectra of dark regions assumed to be composed mainly of dust particles to establish their mineral composition, to eliminate the effects of ices on sub-pixel dusty features, and to look for signatures indicative of Polycyclic Aromatic Hydrocarbons (PAHs). Spectral mapping has identified compositional differences between depression rims and the majority of the SPRC and CRISM spectra have been corrected to minimise the influence of CO2 ice. Whilst no conclusive evidence for PAHs has been found within the detectability limits of the CRISM instrument, depression rims are shown to have higher water content than regions of featureless ice, and there are possible indications of magnesium carbonate within the dark, dusty regions.
Final Reports of the Stardust ISPE: Seven Probable Interstellar Dust Particles
NASA Technical Reports Server (NTRS)
Allen, Carlton; Sans Tresseras, Juan-Angel; Westphal, Andrew J.; Stroud, Rhonda M.; Bechtel, Hans A.; Brenker, Frank E.; Butterworth, Anna L.; Flynn, George J.; Frank, David R.; Gainsforth, Zack;
2014-01-01
The Stardust spacecraft carried the first spaceborne collector specifically designed to capture and return a sample of contemporary interstellar dust to terrestrial laboratories for analysis [1]. The collector was exposed to the interstellar dust stream in two periods in 2000 and 2002 with a total exposure of approximately 1.8 10(exp 6) square meters sec. Approximately 85% of the collector consisted of aerogel, and the remainder consisted of Al foils. The Stardust Interstellar Preliminary Examination (ISPE) was a consortiumbased effort to characterize the collection in sufficient detail to enable future investigators to make informed sample requests. Among the questions to be answered were these: How many impacts are consistent in their characteristics with interstellar dust, with interplanetary dust, and with secondary ejecta from impacts on the spacecraft? Are the materials amorphous or crystalline? Are organics detectable? An additional goal of the ISPE was to develop or refine the techniques for preparation, analysis, and curation of these tiny samples, expected to be approximately 1 picogram or smaller, roughly three orders of magnitude smaller in mass than the samples in other small particle collections in NASA's collections - the cometary samples returned by Stardust, and the collection of Interplanetary Dust Particles collected in the stratosphere.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arnold, S.J.; Markel, H.L.; Morawetz, J.S.
1986-04-01
The International Chemical Workers Union requested an evaluation be made of the health status of employees at the Continental Coffee Products Company, Houston, Texas with particular attention given to potential exposure to pesticide residues on imported coffee beans. Analysis of air samples revealed the following concentration ranges: 29 personal respirable-dust samples ranging from 0.03 to 2.03 milligrams/cubic meter (mg/m3); 27 of 28 personal total dust samples, 0.09 to 2.65 mg/m3; four area respirable-dust samples, 0.11 to 0.53 mg/m3; and four area total dust samples, 0.16 to 2.39 mg/m3. Pesticide exposures were significantly below acceptable daily intakes. The authors conclude thatmore » it would not be expected that employees would be exposed to pesticide levels posing an appreciable threat to health. Recommendations were made to increase the use of local exhaust ventilation; to improve work practices to reduce generation of dust and accumulation; increase ventilation in the basement re-mix operation; and train employees toward the understanding of potential hazards and their role in controlling dust.« less
Fang, Mingliang; Webster, Thomas F.; Gooden, David; Cooper, Ellen M.; McClean, Michael D.; Carignan, Courtney; Makey, Colleen; Stapleton, Heather M.
2013-01-01
With the phase-out of polybrominated diphenyl ether (PBDE) flame retardants, the use of new and alternate flame retardants has been increasing. 2,2-bis(chloromethyl)propane-1,3-diyltetrakis(2-chloroethyl) bisphosphate, known as V6, is a flame retardant applied to polyurethane foam commonly found in furniture and automobile foam. However, to the authors’ knowledge, no research has been conducted on V6 levels in the environment. The intention of this study was to measure the concentration of V6 in foam collected from baby products where it was recently detected, and measure levels in dust samples collected from homes and automobiles in the Boston, MA area. To accomplish this a pure V6 commercial standard was purchased from a Chinese manufacturer and purified (> 98%). An analytical method to measure V6 in dust samples using liquid chromatography tandem mass spectrometry (LC/MS-MS) was developed. Extraction was conducted using Accelerated Solvent Extraction (ASE) and extracts were purified using an ENVI-Florisil SPE column (500 mg, 3mL). V6 was measured in foam samples collected from baby products with a concentration ranging from 24,500,000 to 59,500,000 ng/g of foam (n = 12, average ± sd: 46,500,000 ± 12,000,000 ng/g; i.e., on average, 4.6 % of the foam mass was V6). V6 was also detected in 19 of 20 car dust samples and 14 of 20 house dust samples analyzed. The concentration of V6 in the house dust ranged from < 5 ng/g to 1,110 ng/g with a median of 12.5 ng/g, and < 5 ng/g to 6,160 ng/g in the car dust with a median of 103.0 ng/g. Concentrations in car dust were significantly higher than the house dust, potentially indicating higher use of V6 in automobiles compared to products found in the home. Furthermore, tris (2-chloroethyl) phosphate (TCEP), a known carcinogen, was found in the V6 commercial mixture (14% by weight) as an impurity and was consistently detected with V6 in the foam samples analyzed. A significant correlation was also observed between V6 and TCEP in the dust samples, suggesting that the use of V6 is a significant source of TCEP in the indoor environment. PMID:23565680
NASA Astrophysics Data System (ADS)
Yamamoto, Yuhji; Torii, Masayuki; Natsuhara, Nobuyoshi
2015-05-01
In 1972, a reconstruction experiment of a kiln had been done to reproduce an excavated kiln of the seventh century in Japan. Baked clay samples were taken from the floor surface and -20 cm level, and they have been stored after determinations of the paleomagnetic directions by partial alternating field demagnetizations. We recently applied the Tsunakawa-Shaw method to the samples to assess how reliable archeointensity results are obtained from the samples. A suite of the rock magnetic experiments and the scanning electron microscope observations elucidate that dominant magnetic carriers of the floor surface samples are Ti-poor titanomagnetite grains in approximately 10 nm size with single-domain and/or super-paramagnetic states, whereas contributions of multi-domain grains seem to be relatively large for the -20-cm level samples. From the floor surface samples, six out of the eight successful results were obtained and they give an average of 47.3 μT with a standard deviation of 2.2 μT. This is fairly consistent with the in situ geomagnetic field of 46.4 μT at the time of the reconstruction. They are obtained with a built-in anisotropy correction using anhysteretic remanent magnetization and without any cooling rate corrections. In contrast, only one out of four was successful from the -20-cm level samples. It yields an archeointensity of 31.6 μT, which is inconsistent with the in situ geomagnetic field. Considering from the in situ temperature record during the firing of the kiln and the unblocking temperature spectra of the samples, the floor surface samples acquired full thermoremanent magnetizations (TRMs) as their natural remanent magnetizations whereas the -20-cm level samples only acquired partial TRMs, and these differences probably cause the difference in the archeointensity results between the two sample groups. For archeointensity researches, baked clay samples from a kiln floor are considered to be ideal materials.
Trans boundary transport of pollutants by atmospheric mineral dust.
Erel, Yigal; Dayan, Uri; Rabi, Reut; Rudich, Yinon; Stein, Mordechai
2006-05-01
The transport of anthropogenic pollution by desert dust in the Eastern Mediterranean region was studied by analyzing major and trace element composition, organic species, and Pb isotope ratios in suspended dust samples collected in Jerusalem, Israel. Dust storms in this region are associated with four distinct synoptic conditions (Red Sea Trough (RS), Eastern High (EH), Sharav Cyclone (SC), and Cold Depression (Cyprus low, CD)) that carry dust mostly from North African (SC, CD, EH) and Arabian and Syrian (RS, EH) deserts. Substantial contamination of dust particles by Pb, Cu, Zn, and Ni is observed, while other elements (Na, Ca, Mg, Mn, Sr, Rb, REE, U, and Th) display natural concentrations. Sequential extraction of the abovementioned elements from the dust samples shows that the carbonate and sorbed fractions contain most of the pollution, yet the Al-silicate fraction is also contaminated, implying that soils and sediments in the source terrains of the dust are already polluted. We identified the pollutant sources by using Pb isotopes. It appears that before the beginning of the dust storm, the pollutants in the collected samples are dominated by local sources but with the arrival of dust from North Africa, the proportion of foreign pollutants increases. Organic pollutants exhibit behavior similar and complementary to that of the inorganic tracers, attesting to the importance of anthropogenic-pollutant addition en route of the dust from its remote sources. Pollution of suspended dust is observed under all synoptic conditions, yet it appears that easterly winds carry higher proportions of local pollution and westerly winds carry pollution emitted in the Cairo basin. Therefore, pollution transport by mineral dust should be accounted for in environmental models and in assessing the health-related effects of mineral dust.
Folarin, Bilikis Temitope; Abdallah, Mohamed Abou-Elwafa; Oluseyi, Temilola; Olayinka, Kehinde; Harrad, Stuart
2018-09-01
Concentrations of 7 indicator polychlorinated biphenyls (PCBs) were measured in dust and soil samples from 12 power stations collected over the two major seasons of the Nigerian climate. Median ƩPCB 7 concentrations in soil ranged from 2 ng/g for power station A to 220 ng/g for power station I; while those in dust ranged from 21 ng/g for power station L to 2200 ng/g for power station I. For individual congeners, median PCB concentrations ranged from 3.8 ng/g for PCB 101 to 52 ng/g for PCB 180 in dust, and <0.07 ng/g for PCB 28 to 5.9 ng/g for PCB 153 in soil. The type of power station activity exerted a significant influence on concentrations of ΣPCB 7 in dust and soil (generation > transmission > distribution). Congener patterns in dust and soil samples were compared using principal component analysis (PCA) with those in transformer oil samples from 3 of the power stations studied and with common PCB mixtures (Aroclors). This revealed congener patterns in soil were more closely related to that in the transformer oil than dust. Congener patterns in most samples were similar to Aroclor 1260. Concentrations of PCBs in soil samples close to the transformers significantly exceeded those in soil sampled further away. Copyright © 2018 Elsevier Ltd. All rights reserved.
Klees, Marcel; Hiester, Ernst; Bruckmann, Peter; Schmidt, Torsten C
2013-07-26
Owing to massive pollution with polychlorinated biphenyls in the harbour area of Dortmund (Germany), several dust samples were taken from surfaces at industrial sites and analyzed by the North-Rhine Westphalian State Agency for Nature, Environment, and Consumer Protection (LANUV NRW). This report describes and validates a rapid approach to screening for the presence of polychlorinated biphenyls (PCBs) in street dust. Samples were collected by using a natural bristle brush and stainless steel scoops. Mass recovery of fine-particle sea sand (a dust surrogate) on asphalt and concrete surfaces was used as a criterion for the effectiveness of sampling. Better recoveries of sea sand were achieved on concrete than on asphalt surfaces. Furthermore, temperature optimization for a pressurized liquid extraction (PLE) method used to extract PCBs and polychlorinated dibenzodioxins and polychlorinated furans (PCDD/Fs) from street dust samples was developed and compared with Soxhlet extraction for the analysis of PCBs in real street dust samples. Toluene was used as the extraction solvent in both cases. During this study, a combination of toluene and PLE achieved better extraction efficiencies than Soxhlet extraction. Finally, the performance of the PLE method was evaluated by analysing NIST Standard Reference Material 1649a for PCB and PCDD/F concentrations. This demonstrated that the accuracy of the PLE method for the determination of both substance classes was satisfactory. In addition, concentrations of PCBs and PCDD/Fs in street dust samples from industrial sites are reported. Copyright © 2013. Published by Elsevier B.V.
Polycyclic Aromatic Hydrocarbons in Residential Dust: Sources of Variability
Metayer, Catherine; Petreas, Myrto; Does, Monique; Buffler, Patricia A.; Rappaport, Stephen M.
2013-01-01
Background: There is interest in using residential dust to estimate human exposure to environmental contaminants. Objectives: We aimed to characterize the sources of variability for polycyclic aromatic hydrocarbons (PAHs) in residential dust and provide guidance for investigators who plan to use residential dust to assess exposure to PAHs. Methods: We collected repeat dust samples from 293 households in the Northern California Childhood Leukemia Study during two sampling rounds (from 2001 through 2007 and during 2010) using household vacuum cleaners, and measured 12 PAHs using gas chromatography–mass spectrometry. We used a random- and a mixed-effects model for each PAH to apportion observed variance into four components and to identify sources of variability. Results: Median concentrations for individual PAHs ranged from 10 to 190 ng/g of dust. For each PAH, total variance was apportioned into regional variability (1–9%), intraregional between-household variability (24–48%), within-household variability over time (41–57%), and within-sample analytical variability (2–33%). Regional differences in PAH dust levels were associated with estimated ambient air concentrations of PAH. Intraregional differences between households were associated with the residential construction date and the smoking habits of residents. For some PAHs, a decreasing time trend explained a modest fraction of the within-household variability; however, most of the within-household variability was unaccounted for by our mixed-effects models. Within-household differences between sampling rounds were largest when the interval between dust sample collections was at least 6 years in duration. Conclusions: Our findings indicate that it may be feasible to use residential dust for retrospective assessment of PAH exposures in studies of health effects. PMID:23461863
Relating Optical Properties of Dusts to their Mineralogical and Physical Interrelationships
NASA Astrophysics Data System (ADS)
Engelbrecht, J. P.; Moosmuller, H.; Jayanty, R. K. M.; Casuccio, G.; Pincock, S. L.
2015-12-01
The purpose of the project was to provide information on the mineralogical, chemical and physical interrelationships of re-suspended mineral dust samples collected as grab samples from global dust sources. Surface soil samples were collected from about 65 desert sites, including the southwestern USA (12), Mali (3), Chad (3), Morocco (1), Canary Islands (8), Cape Verde (1), Djibouti (1), Afghanistan (3), Iraq (6), Kuwait (5), Qatar (1), UAE (1), Serbia (3), China (5), Namibia (3), Botswana (4), Australia (3), and Chile (1). The < 38 μm sieved fraction of each sample was re-suspended in an entrainment chamber, from which the airborne mineral dust could be monitored, sampled and analyzed. Instruments integrated into the entrainment facility included two PM10 and two PM2.5 filter samplers, a beta attenuation gauge for the continuous measurement of PM10 and PM2.5particulate mass fractions, an aerodynamic particle size (APS) analyzer, and a three wavelength (405, 532, 781nm) photoacoustic resonator with integrating reciprocal nephelometer for monitoring absorption and scattering coefficients during the dust re-suspension process. Filter sample media included Teflon® membrane and quartz fiber filters for chemical analysis (71 species), and Nuclepore® filters for individual particle analysis by Scanning Electron Microscopy (SEM). The < 38 μm sieved fractions were also analyzed by X-ray diffraction for their mineral content while the > 38 μm, < 125 μm soil fractions were mineralogically characterized by optical microscopy. We will be presenting results on the optical measurements, also showing the relationship between single scattering albedo (SSA) at three different wavelengths, and chemical as well as mineralogical content and interdependencies of the entrained dust samples. Examples showing the relationships between the single scattering albedos of airborne dusts, and iron (Fe) in hematite, goethite, and clay minerals (montmorillonite, illite, palygorskite), will be discussed. Our goal is to establish a database of the optical, mineralogical, and chemical properties of dust samples collected at multiple global dust sources. These data can be for applications in climate modeling, remote sensing, visibility, health (medical geology), ocean fertilization, and damage to equipment.
Evaluation of a Dust Control for a Small Slab-Riding Dowel Drill for Concrete Pavement
Echt, Alan; Mead, Kenneth
2016-01-01
Purpose To assess the effectiveness of local exhaust ventilation to control respirable crystalline silica exposures to acceptable levels during concrete dowel drilling. Approach Personal breathing zone samples for respirable dust and crystalline silica were collected while laborers drilled holes 3.5 cm diameter by 36 cm deep in a concrete slab using a single-drill slab-riding dowel drill equipped with local exhaust ventilation. Data were collected on air flow, weather, and productivity. Results All respirable dust samples were below the 90 µg detection limit which, when combined with the largest sample volume, resulted in a minimum detectable concentration of 0.31 mg m−3. This occurred in a 32-min sample collected when 27 holes were drilled. Quartz was only detected in one air sample; 0.09 mg m−3 of quartz was found on an 8-min sample collected during a drill maintenance task. The minimum detectable concentration for quartz in personal air samples collected while drilling was performed was 0.02 mg m−3. The average number of holes drilled during each drilling sample was 23. Over the course of the 2-day study, air flow measured at the dust collector decreased from 2.2 to 1.7 m3 s−1. Conclusions The dust control performed well under the conditions of this test. The initial duct velocity with a clean filter was sufficient to prevent settling, but gradually fell below the recommended value to prevent dust from settling in the duct. The practice of raising the drill between each hole may have prevented the dust from settling in the duct. A slightly higher flow rate and an improved duct design would prevent settling without regard to the position of the drill. PMID:26826033
Guo, Jiehong; Stubbings, William A; Romanak, Kevin; Nguyen, Linh V; Jantunen, Liisa; Melymuk, Lisa; Arrandale, Victoria; Diamond, Miriam L; Venier, Marta
2018-03-20
A high molecular weight compound, 2,4,6-tris(2,4,6-tribromophenoxy)-1,3,5-triazine (TTBP-TAZ), was detected during the analysis of brominated flame retardants in dust samples collected from an electrical and electronic waste (e-waste) recycling facility in Ontario, Canada. Gas chromatography coupled with both high-resolution and low-resolution mass spectrometry (MS) was used to determine TTBP-TAZ's chemical structure and concentrations. To date, TTBP-TAZ has only been detected in plastic casings of electrical and electronic equipment and house dust from The Netherlands. Here we report on the concentrations of TTBP-TAZ in selected samples from North America: e-waste dust ( n = 7) and air ( n = 4), residential dust ( n = 30), and selected outdoor air ( n = 146), precipitation ( n = 19), sediment ( n = 11) and water ( n = 2) samples from the Great Lakes environment. TTBP-TAZ was detected in all the e-waste dust and air samples, and in 70% of residential dust samples. The median concentrations of TTBP-TAZ in these three types of samples were 5540 ng/g, 5.75 ng/m 3 and 6.76 ng/g, respectively. The flame retardants 2,4,6-tribromophenol, tris(2,3-dibromopropyl) isocyanurate, and 3,3',5,5'-tetrabromobisphenol A bis(2,3-dibromopropyl) ether, BDE-47 and BDE-209 were also measured for comparison. None of these other flame retardants concentrations was significantly correlated with those of TTBP-TAZ in any of the sample types suggesting different sources. TTBP-TAZ was not detected in any of the outdoor environmental samples, which may relate to its application history and physicochemical properties. This is the first report of TTBP-TAZ in North America.
Evaluation of a Dust Control for a Small Slab-Riding Dowel Drill for Concrete Pavement.
Echt, Alan; Mead, Kenneth
2016-05-01
To assess the effectiveness of local exhaust ventilation to control respirable crystalline silica exposures to acceptable levels during concrete dowel drilling. Personal breathing zone samples for respirable dust and crystalline silica were collected while laborers drilled holes 3.5 cm diameter by 36 cm deep in a concrete slab using a single-drill slab-riding dowel drill equipped with local exhaust ventilation. Data were collected on air flow, weather, and productivity. All respirable dust samples were below the 90 µg detection limit which, when combined with the largest sample volume, resulted in a minimum detectable concentration of 0.31 mg m(-3). This occurred in a 32-min sample collected when 27 holes were drilled. Quartz was only detected in one air sample; 0.09 mg m(-3) of quartz was found on an 8-min sample collected during a drill maintenance task. The minimum detectable concentration for quartz in personal air samples collected while drilling was performed was 0.02 mg m(-3). The average number of holes drilled during each drilling sample was 23. Over the course of the 2-day study, air flow measured at the dust collector decreased from 2.2 to 1.7 m(3) s(-1). The dust control performed well under the conditions of this test. The initial duct velocity with a clean filter was sufficient to prevent settling, but gradually fell below the recommended value to prevent dust from settling in the duct. The practice of raising the drill between each hole may have prevented the dust from settling in the duct. A slightly higher flow rate and an improved duct design would prevent settling without regard to the position of the drill. Published by Oxford University Press on behalf of the British Occupational Hygiene Society 2016.
NASA Astrophysics Data System (ADS)
Stein, M.; Palchan, D.; Goldstein, S. L.; Almogi-Labin, A.; Tirosh, O.; Erel, Y.
2017-12-01
The last interglacial peak, Marine Isotope Stage 5e (MIS 5e), was associated with stronger northern hemisphere insolation, higher global sea levels and higher average global temperatures compared to the Holocene, and is considered as an analogue for a future warming world. In this perspective the present-day areas of the Sahara - Arabia deserts (the "desert belt") are of special interest since their margins are densely inhabited and global climate models predict enhanced aridity in these regions due to future warming. The Red Sea situated at the midst of the desert belt and the Dead Sea at the northern fringe of the desert belt comprise sensitive monitors for past hydroclimate changes in the Red Sea-Levant regions as global climate shifted from glacial to interglacial conditions. Here, we reconstruct the synoptic conditions that controlled desert dust transport to the Red Sea and the Dead Sea during MIS5e. The reconstruction is based on Nd-Sr isotopes and chemical composition of carbonate-free detritus recovered from sediment cores drilled at the deep floors of these water-bodies combined with data of contemporaneous dust storms transporting dust to the lake and sea floors. During Termination 2 ( 134-130 ka) the Sahara, Nile River desiccated and the Dead Sea watershed were under extreme dry conditions manifested by lake level drop, deposition of salt and enhanced transport of Sahara dusts to the entire studied transect. At the peak of the interglacial MIS 5e ( 130-120 ka), enhanced flooding activity mobilized local fine detritus from the surroundings of the Red Sea and the Dead Sea watershed into the water-bodies. This interval coincided with the Sapropel event S5 in the Mediterranean that responded to enhanced monsoon rains at the heads of the Blue Nile River. At the end of MIS 5e ( 120-116 ka) the effect of the regional floods faded and the Dead Sea and Red Sea areas re-entered sever arid conditions with salt deposition at the Dead Sea. Overall, the desert margins were under turbulent climate regime during the last interglacial period, fluctuating between contraction and expansions manifested with extreme enhanced flooding and extreme arid spells.
NASA Technical Reports Server (NTRS)
Arvidson, R. E.; Squyres, S. W,; Anderson, R. C.; Bell, J. F., III; Blaney, D.; Brueckner, J.; Cabrol, N. A.; Calvin, W. M.; Carr, M. H.; Christensen, P. R.;
2005-01-01
Spirit landed on the floor of Gusev Crater and conducted initial operations on soil covered, rock-strewn cratered plains underlain by olivine-bearing basalts. Plains surface rocks are covered by wind-blown dust and show evidence for surface enrichment of soluble species as vein and void-filling materials and coatings. The surface enrichment is the result of a minor amount of transport and deposition by aqueous processes. Layered granular deposits were discovered in the Columbia Hills, with outcrops that tend to dip conformably with the topography. The granular rocks are interpreted to be volcanic ash and/or impact ejecta deposits that have been modified by aqueous fluids during and/or after emplacement. Soils consist of basaltic deposits that are weakly cohesive, relatively poorly sorted, and covered by a veneer of wind blown dust. The soils have been homogenized by wind transport over at least the several kilometer length scale traversed by the rover. Mobilization of soluble species has occurred within at least two soil deposits examined. The presence of mono-layers of coarse sand on wind-blown bedforms, together with even spacing of granule-sized surface clasts, suggest that some of the soil surfaces encountered by Spirit have not been modified by wind for some time. On the other hand, dust deposits on the surface and rover deck have changed during the course of the mission. Detection of dust devils, monitoring of the dust opacity and lower boundary layer, and coordinated experiments with orbiters provided new insights into atmosphere-surface dynamics.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-29
... for OMB Review; Comment Request; Coal Mine Dust Sampling Devices ACTION: Notice. SUMMARY: The... information collection request (ICR) titled, ``Coal Mine Dust Sampling Devices,'' to the Office of Management...) determine the concentration of respirable dust in coal mines. CPDMs must be designed and constructed for...
30 CFR 90.209 - Respirable dust samples; transmission by operator.
Code of Federal Regulations, 2010 CFR
2010-07-01
... designated by the District Manager. (b) The operator shall not open or tamper with the seal of any filter... properly complete the dust data card that is provided by the manufacturer for each filter cassette. The... include that person's certification number. Respirable dust samples with data cards not properly completed...
30 CFR 90.209 - Respirable dust samples; transmission by operator.
Code of Federal Regulations, 2011 CFR
2011-07-01
... designated by the District Manager. (b) The operator shall not open or tamper with the seal of any filter... properly complete the dust data card that is provided by the manufacturer for each filter cassette. The... include that person's certification number. Respirable dust samples with data cards not properly completed...
30 CFR 71.209 - Respirable dust samples; transmission by operator.
Code of Federal Regulations, 2010 CFR
2010-07-01
... designated by the District Manager. (b) The operator shall not open or tamper with the seal of any filter... properly complete the dust data card that is provided by the manufacturer for each filter cassette. The... include that person's certification number. Respirable dust samples with data cards not properly completed...
30 CFR 71.209 - Respirable dust samples; transmission by operator.
Code of Federal Regulations, 2011 CFR
2011-07-01
... designated by the District Manager. (b) The operator shall not open or tamper with the seal of any filter... properly complete the dust data card that is provided by the manufacturer for each filter cassette. The... include that person's certification number. Respirable dust samples with data cards not properly completed...
Size Distributions and Characterization of Native and Ground Samples for Toxicology Studies
NASA Technical Reports Server (NTRS)
McKay, David S.; Cooper, Bonnie L.; Taylor, Larry A.
2010-01-01
This slide presentation shows charts and graphs that review the particle size distribution and characterization of natural and ground samples for toxicology studies. There are graphs which show the volume distribution versus the number distribution for natural occurring dust, jet mill ground dust, and ball mill ground dust.
Teschke, K; Hertzman, C; Morrison, B
1994-03-01
Personal respirable (N = 230) and total (N = 237) dust measurements were made in two coastal British Columbia sawmills using a sampling strategy that randomly selected workers from all jobs in the mills over two seasons. Information about job title, department, season, weather conditions, location of the job relative to wood-cutting machines, and control measures also was collected at the time of sampling. Only 16 respirable wood dust samples were above the detection limit of 0.08 mg/m3; all 16 had levels < or = 0.20 mg/m3. Total wood dust concentrations were also low (36% less than the detection limit), with a mean of 0.51 mg/m3, and ranging from < 0.08 to 52 mg/m3. Measurements of exposure taken close to chippers, planers, and multiple saws had the highest total wood dust levels. Sawmill department and booth enclosures also were associated with wood dust concentrations, while local exhaust ventilation and weather conditions were not. Wood dust levels in this study were generally lower than in other studies of this industry, but most sawmill investigations report mean wood dust concentrations lower than those measured in the furniture and cabinetmaking industries, where concerns about wood dust exposures initially were raised.
Shi, Zongbo; Krom, Michael D; Bonneville, Steeve; Baker, Alex R; Jickells, Timothy D; Benning, Liane G
2009-09-01
The formation of iron (Fe) nanoperticles and increase in Fe reactivity in mineral dust during simulated cloud processing was investigated using high-resolution microscopy and chemical extraction methods. Cloud processing of dust was experimentally simulated via an alternation of acidic (pH 2) and circumneutral conditions (pH 5-6) over periods of 24 h each on presieved (<20 microm) Saharan soil and goethite suspensions. Microscopic analyses of the processed soil and goethite samples reveal the neo-formation of Fe-rich nanoparticle aggregates, which were not found initially. Similar Fe-rich nanoparticles were also observed in wet-deposited Saharen dusts from the western Mediterranean but not in dry-deposited dust from the eastern Mediterranean. Sequential Fe extraction of the soil samples indicated an increase in the proportion of chemically reactive Fe extractable by an ascorbate solution after simulated cloud processing. In addition, the sequential extractions on the Mediterranean dust samples revealed a higher content of reactive Fe in the wet-deposited dust compared to that of the dry-deposited dust These results suggestthat large variations of pH commonly reported in aerosol and cloud waters can trigger neo-formation of nanosize Fe particles and an increase in Fe reactivity in the dust
Webster, Thomas F.; Harrad, Stuart; Millette, James R.; Holbrook, R. David; Davis, Jeffrey M.; Stapleton, Heather M.; Allen, Joseph G.; McClean, Michael D.; Ibarra, Catalina; Abdallah, Mohamed Abou-Elwafa; Covaci, Adrian
2009-01-01
Although the presence of polybrominated diphenyl ethers (PBDEs) in house dust has been linked to consumer products, the mechanism of transfer remains poorly understood. We conjecture that volatilized PBDEs will be associated with dust particles containing organic matter and will be homogeneously distributed in house dust. In contrast, PBDEs arising from weathering or abrasion of polymers should remain bound to particles of the original polymer matrix and will be heterogeneously distributed within the dust. We used scanning electron microscopy and other tools of environmental forensic microscopy to investigate PBDEs in dust, examining U.S.A. and U.K. dust samples with extremely high levels of BDE 209 (260–2600 µg/g), a non-volatile compound at room temperature. We found that the bromine in these samples was concentrated in widely scattered, highly contaminated particles. In the house dust samples from Boston (U.S.), bromine was associated with a polymer/organic matrix. These results suggest that the BDE 209 was transferred to dust via physical processes such as abrasion or weathering. In conjunction with more traditional tools of environmental chemistry, such as gas chromatography-mass spectrometry (GC/MS), environmental forensic microscopy provides novel insights into the origins of BDE 209 in dust and their mechanisms of transfer from products. PMID:19534115
Thompson, Katy-Anne; Paton, Susan; Pottage, Thomas; Bennett, Allan
2018-05-09
Four commercially available robotic vacuum cleaners were assessed for sampling efficiency of wet disseminated Bacillus atrophaeus spores on carpet, Polyvinyl Chloride (PVC) and laminate flooring. Furthermore, their operability was evaluated and decontamination efficiency of one robot was assessed using a sodium hypochlorite solution. In an environmental chamber, robots self-navigated around 4 m 2 of flooring containing a single contaminated 0.25 m 2 tile (ca. 10 4 spores per cm 2 ). Contamination levels at pre-determined locations were assessed by macrofoam swabs (PVC and laminate) or water soluble tape (carpet), before and after sampling. Robots were dismantled post-sampling and spore recoveries assessed. Aerosol contamination was also measured during sampling. Robot sampling efficiencies were variable, however, robots recovered most spores from laminate (up to 17.1%), then PVC, and lastly carpet. All robots spread contamination from the 'hotspot' (all robots spread < 0.6% of the contamination to other areas) and became surface contaminated. Spores were detected at low levels during air sampling (<5.6 spores l -1 ). Liquid decontamination inactivated 99.1% of spores from PVC. Robotic vacuum cleaners show promise for both sampling and initial decontamination of indoor flooring. In the event of a bioterror incident, e.g. deliberate release of Bacillus anthracis spores, areas require sampling to determine the magnitude and extent of contamination, and to establish decontamination efficacy. In this study we investigate robotic sampling methods against high concentrations of bacterial spores applied by wet deposition to different floorings, contamination spread to other areas, potential transfer of spores to the operators and assessment of a wet vacuum robot for spore inactivation. The robots' usability was evaluated and how they can be employed in real life scenarios. This will help to reduce the economic cost of sampling and the risk to sampling/decontamination teams. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
NASA Astrophysics Data System (ADS)
Ogundele, Lasun T.; Olasinde, Roseline T.; Owoade, Oyediran K.; Olise, Felix S.
2018-05-01
This study presents the elemental compositions and concentrations of indoor dust and identifies the major sources in some selected indoor environments in Ile-Ife, Nigeria. The dust samples were collected from 16 indoor environments comprising offices, churches, residential and staff quarters using a cyclonic high power vacuum cleaner. The dust samples were analyzed for elemental concentrations using x-ray fluorescences. The data sets were analyzed for the possible sources and their contributions using Principal Component Factor Analysis (PCFA). The result showed that dust samples contained several elements: K, Ca, Ti, Mn, Fe, Ni, Cu, Zn, Ga, As, Rb, Sr, Se, Zr, V, and Sc. The PCFA identified three factors with the percentage variance of 92, 77, 71 and 68%, for the office, church, residential, and staff quarters, respectively, for the combined elemental data of each of the site classes. The identified sources were track-in-soil, road and windblown soil dust, paint debris, household dust from personal care materials, cooking, and cleaning activities. The unintentional track-in-soil due to mobility of the occupants, structural materials, and outdoor air was the major sources contributing to the indoor dust.
Trace-metal accumulation, distribution, and fluxes in forests of the northeastern United States
DOE Office of Scientific and Technical Information (OSTI.GOV)
Friedland, A.J.
1985-01-01
Forest floor was sampled at 78 sites in nine northeastern states in the USA and analyzed for Cu, Zn, Ni, and Cd. Higher levels of trace metals occurred in the southern half of the study region. Earlier work identified that Pb accumulated in the forest floor of the high-elevation regions of New England. The distribution of Pb, Cu, Zn, Ni, and Cd within the forest floor was studied at three different forested states in New England. The greatest concentration of Pb, Cu, Zn, Ni, and Cd occurred in the Oe horizon of the forest floor in all three forests. Thismore » is the zone of greatest biological activity in the forest floor. Because it receives relatively high rates of atmospheric deposition, Camels Hump in northern Vermont was studied in greater detail. Lead concentration and amount in the forest floor increased between 550 and 1160 m elevation. Comparisons with 1966 and 1977 samples from the same stands showed that Pb, Cu, and Zn concentrations increased by as much as 148% in the intervening 14 years. Estimated deposition rates of Pb, Cu, and Zn based on accumulation rates agreed with regional deposition rates reported in the literature. Lead concentrations were an order of magnitude lower in mineral soil and vegetation than in forest floor. Thus the most likely source of forest floor Pb is the atmosphere. Lead was strongly retained by the forest floor and approximately 3% of the current Pb content of the forest floor is added each year by atmospheric deposition. At the current accumulation rates, the amount of Pb in the forest floor will double in three to four decades.« less
NASA Astrophysics Data System (ADS)
Goldstein, H. L.; Reynolds, R. L.; Landry, C.; Derry, J. E.; Kokaly, R. F.; Breit, G. N.
2016-12-01
Dust deposited on mountain snow cover (DOS) changes snow albedo, enhances absorption of solar radiation, and effectively increases rates of snow melt, leading to earlier-than-normal runoff and overall smaller late-season water supplies for tens of millions of people and industries in the American West. Visible-spectrum reflectance of DOS samples is on the order of 0.2 (80% absorption), in stark contrast to the high reflectivity of pure snow which approaches 1.0. Samples of DOS were collected from 12 high-elevation Colorado mountain sites near the end of spring from 2013 through 2016 prior to complete snow melt, when most dust layers had merged into one layer. These samples were analyzed to measure dust properties that affect snow albedo and to link DOS to dust-source areas. Dust mass loadings to snow during water year 2014 varied from 5 to 30 g/m2. Median particle sizes centered around 20 micrometers with more than 80% of the dust <63 micrometers. Dark minerals, carbonaceous matter, and iron oxides, including nano-sized hematite and goethite, together diminished reflectance according to their variable concentrations. Documenting variations in dust-particle masses, sizes, and compositions helps determine their influences on snow-melt and may be useful for modeling snow-melt effects from future dust. Furthermore, variations in dust components and particle sizes lead to new ways to recognize sources of dust by comparison with properties of fine-grained sediments in dust-source areas. Much of the DOS in the San Juan Mountains, Colorado can be linked to southern Colorado Plateau source areas by compositional similarities and satellite imagery. Understanding dust properties that affect snow albedo and recognizing the sources of dust deposited on snow cover may guide mitigation of dust emission that affects water resources of the Colorado River basin.
Wagner, Jeff; Ghosal, Sutapa; Whitehead, Todd; Metayer, Catherine
2013-09-01
We characterized flame retardant (FR) morphologies and spatial distributions in 7 consumer products and 7 environmental dusts to determine their implications for transfer mechanisms, human exposure, and the reproducibility of gas chromatography-mass spectrometry (GC-MS) dust measurements. We characterized individual particles using scanning electron microscopy/energy dispersive x-ray spectroscopy (SEM/EDS) and Raman micro-spectroscopy (RMS). Samples were screened for the presence of 3 FR constituents (bromine, phosphorous, non-salt chlorine) and 2 metal synergists (antimony and bismuth). Subsequent analyses of select samples by RMS enabled molecular identification of the FR compounds and matrix materials. The consumer products and dust samples possessed FR elemental weight percents of up to 36% and 31%, respectively. We identified 24 FR-containing particles in the dust samples and classified them into 9 types based on morphology and composition. We observed a broad range of morphologies for these FR-containing particles, suggesting FR transfer to dust via multiple mechanisms. We developed an equation to describe the heterogeneity of FR-containing particles in environmental dust samples. The number of individual FR-containing particles expected in a 1-mg dust sample with a FR concentration of 100ppm ranged from <1 to >1000 particles. The presence of rare, high-concentration bromine particles was correlated with decabromodiphenyl ether concentrations obtained via GC-MS. When FRs are distributed heterogeneously in highly concentrated dust particles, human exposure to FRs may be characterized by high transient exposures interspersed by periods of low exposure, and GC-MS FR concentrations may exhibit large variability in replicate subsamples. Current limitations of this SEM/EDS technique include potential false negatives for volatile and chlorinated FRs and greater quantitation uncertainty for brominated FR in aluminum-rich matrices. Copyright © 2013 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
2006-01-01
2 July 2006 This Mars Global Surveyor (MGS) Mars Orbiter Camera (MOC) image shows a portion of a trough cutting across a dust-covered plain in the Labeatis Fossae region of Mars. Boulders derived from the layered exposures near the top of the trough walls are resting on the floor, and in some locations, the sloping sidewalls of the dusty trough. Location near: 22.1oN, 94.5oW Image width: 3 km (1.9 mi) Illumination from: lower left Season: Northern Spring50. VIEW OF CRUSHER ADDITION FROM EAST. SHOWS 100TON STEEL ...
50. VIEW OF CRUSHER ADDITION FROM EAST. SHOWS 100-TON STEEL UNOXIDIZED ORE BIN, STEPHENS-ADAMSON 15 TON/HR INCLINED BUCKET ELEVATOR, AND DUST COLLECTION BIN IN UPPER RIGHT QUADRANT. THE ROD MILL CIRCUIT STOOD IN FRONT OF THE BUCKET ELEVATOR AND BEHIND THE BAKER COOLER (LEFT CENTER). MILL SOLUTION TANKS WERE IN FRONT OF THE CRUSHED OXIDIZED ORE BIN (CENTER), AND THE MILL FLOOR WAS THE NEXT LEVEL DOWN (RIGHT). - Bald Mountain Gold Mill, Nevada Gulch at head of False Bottom Creek, Lead, Lawrence County, SD
NASA Astrophysics Data System (ADS)
Clark, C. J. R.; Dunne, L.; Gomez, H. L.; Maddox, S.; De Vis, P.; Smith, M. W. L.; Eales, S. A.; Baes, M.; Bendo, G. J.; Bourne, N.; Driver, S. P.; Dye, S.; Furlanetto, C.; Grootes, M. W.; Ivison, R. J.; Schofield, S. P.; Robotham, A. S. G.; Rowlands, K.; Valiante, E.; Vlahakis, C.; van der Werf, P.; Wright, A. H.; de Zotti, G.
2015-09-01
We present the properties of the first 250 μm blind sample of nearby galaxies (15 < D < 46 Mpc) containing 42 objects from the Herschel Astrophysical Terahertz Large Area Survey. Herschel's sensitivity probes the faint end of the dust luminosity function for the first time, spanning a range of stellar mass (7.4 < M⋆ < 11.3 log10 M⊙), star formation activity (-11.8 < SSFR < -8.9 log10 yr-1), gas fraction (3-96 per cent), and colour (0.6 < FUV-KS < 7.0 mag). The median cold dust temperature is 14.6 K, colder than in the Herschel Reference Survey (18.5 K) and Planck Early Release Compact Source Catalogue (17.7 K). The mean dust-to-stellar mass ratio in our sample is higher than these surveys by factors of 3.7 and 1.8, with a dust mass volume density of (3.7 ± 0.7) × 105 M⊙ Mpc-3. Counter-intuitively, we find that the more dust rich a galaxy, the lower its UV attenuation. Over half of our dust-selected sample are very blue in FUV-KS colour, with irregular and/or highly flocculent morphology; these galaxies account for only 6 per cent of the sample's stellar mass but contain over 35 per cent of the dust mass. They are the most actively star-forming galaxies in the sample, with the highest gas fractions and lowest UV attenuation. They also appear to be in an early stage of converting their gas into stars, providing valuable insights into the chemical evolution of young galaxies.
Study of road dust magnetic phases as the main carrier of potentially harmful trace elements.
Bourliva, Anna; Papadopoulou, Lambrini; Aidona, Elina
2016-05-15
Mineralogical and morphological characteristics and heavy metal content of different fractions (bulk, non-magnetic fraction-NMF and magnetic fraction-MF) of road dusts from the city of Thessaloniki (Northern Greece) were investigated. Main emphasis was given on the magnetic phases extracted from these dusts. High magnetic susceptibility values were presented, whereas the MFs content of road dust samples ranged in 2.2-14.7 wt.%. Thermomagnetic analyses indicated that the dominating magnetic carrier in all road dust samples was magnetite, while the presence of hematite and iron sulphides in the investigated samples cannot be excluded. SEM/EDX analyses identified two groups of ferrimagnetic particles: spherules with various surface morphologies and textures and angular/aggregate particles with elevated heavy metal contents, especially Cr. The road dusts (bulk samples) were dominated by calcium, while the mean concentrations of trace elements decreased in the order Zn > Mn > Cu > Pb > Cr > Ni > V > Sn > As > Sb > Co > Mo > W > Cd. MFs exhibited significantly higher concentrations of trace elements compared to NMFs indicating that these potentially harmful elements (PHEs) are preferentially enriched in the MFs and highly associated with the ferrimagnetic particles. Hazard Index (HI) obtained for both adults and children through exposure to bulk dust samples were lower or close to the safe level (=1). On the contrary, the HIs for the magnetic phases indicated that both children and adults are experiencing potential health risk since HI for Cr was significantly higher than safe level. Cancer risk due to road dust exposure is low. Copyright © 2016 Elsevier B.V. All rights reserved.
Sulfate and nitrate in Asian dust particles observed in desert, coastal and marine air
NASA Astrophysics Data System (ADS)
Zhang, D.; Wu, F.; Junji, C.
2016-12-01
Sulfate and nitrate in dust particles are believed to be two key species which can largely alter the physical and chemical properties of the particles in the atmosphere, in particular under humid conditions. Their occurrence in the particles has usually been considered to be the consequence of particles' aging during their long-distance travel in the air although they are present in some crustal minerals. Our observations at two deserts in China during dust episodes revealed that there were soil-derived sulfate and background-like nitrate in atmospheric dust samples. Sulfate in dust samples was proportional to samples' mass and comprised at steady mass percentages in differently sized samples. In contrast, nitrate concentration was approximately stable and independent from dust loading. Our observations at inland and coastal areas of China during dust episodes revealed that sulfate and nitrate were hardly produced on the surface of dust particles that were originated from the deserts areas in northwestern China. This is because the dust particles were in the postfrontal air, where the temperature was low and the relative humidity was small due to the adiabatic properties of the air mass. There are a number studies reporting that sulfate and nitrate had been efficiently produced on mineral particles in inland areas of China. However, those mineral particles were more likely from the local areas rather than from the desert areas. Our observations in the coastal areas of Japan, which is located in the downstream areas of the Asian continent and surrounded by sea areas revealed that dust particles appearing there frequently contained sulfate and nitrate, indicating sulfate and nitrate had been efficiently produced on the surface of the particles when the particles traveled in the marine air between China and Japan.
NASA Astrophysics Data System (ADS)
Marsden, N. A.; Allan, J. D.; Flynn, M.; Ullrich, R.; Moehler, O.; Coe, H.
2017-12-01
The mineralogy of individual dust particles is important for atmospheric processes because mineralogy influences optical properties, their potential to act as ice nucleating particles (INP) and geochemical cycling of elements to the ocean. Bulk mineralogy of transported mineral dust has been shown to be a reflection of the source area and size fractionation during transport. Online characterisation of single particle mineralogy is highly desirable as the composition of individual particles can be reported at a temporal resolution that is relevant to atmospheric processes. Single particle mass spectrometry (SPMS) has indentified and characterised the composition of ambient dust particles but is hampered by matrix effects that result in a non-quantatative measurement of composition. The work presented describes a comparison of mass spectral characteristics of sub 2.5μm particle fractions generated from; i) nominally pure samples from the clay mineral society (CMS), ii) soil samples collected from potential source areas in North Africa and iii) ambient measurement of transported African dust made at the Cape Verde Islands. Using a novel approach to analyse the mass spectra, the distinct characteristics of the various dust samples are obtained from the online measurements. Using this technique it was observed that dust generated from sources on the North West Margin of the Sahara Desert have distinct characteristics of illite in contrast to the kaolinitic characteristics of dust generated from sources in the Sahel. These methods offer great potential for describing the hourly variation in the source and mineralogy of transported mineral dust and the online differentiation of mineral phase in multi-mineralic dust samples.
Jiang, Hong; Lin, Zhenkun; Wu, Yuanyuan; Chen, Xiangping; Hu, Yabing; Li, Yanyan; Huang, Changjiang; Dong, Qiaoxiang
2014-07-15
This study was designed to estimate the human risk to polybrominated diphenyl ethers (PBDEs) exposure via two main exposure routes (dust and diet) in an e-waste recycling area in southern China. A total of 134 dust samples and 129 food samples were analyzed by gas chromatography/mass spectrometry (GC/MS). The mean concentration of ΣPBDE in in-house dust (38,685ng/g dw) was higher than that in out-house dust (24,595ng/g). For food samples, the highest concentration of ΣPBDE was found in fish and shellfish (2755ng/kg ww), followed in descending order by eggs (2423ng/kg), cereals (2239ng/kg) and meat (1799ng/kg). The estimated total daily dietary intake of PBDEs was 1671ng/day for adults and 952ng/day for children. The present study indicated that dust intake was the dominant PBDE exposure route for children, and the dietary intake was the dominant PBDE exposure route for adults. Our findings revealed high PBDE concentrations in dust and food samples collected at the center of e-waste recycling area, raising significant health concerns for residents in this particular region, especially for children. Copyright © 2014 Elsevier B.V. All rights reserved.
We studied the relationship between dust mite antigen concentrations in house dust samples and the occurrence and frequency of wheezing in 58 children with dust mite allergy (wheal > 4 mm. mean diameter in response to a prick test with either D-. farinae or D pteronyssinus antige...
Evaluation of coral pathogen growth rates after exposure to atmospheric African dust samples
Lisle, John T.; Garrison, Virginia H.; Gray, Michael A.
2014-01-01
Laboratory experiments were conducted to assess if exposure to atmospheric African dust stimulates or inhibits the growth of four putative bacterial coral pathogens. Atmospheric dust was collected from a dust-source region (Mali, West Africa) and from Saharan Air Layer masses over downwind sites in the Caribbean [Trinidad and Tobago and St. Croix, U.S. Virgin Islands (USVI)]. Extracts of dust samples were used to dose laboratory-grown cultures of four putative coral pathogens: Aurantimonas coralicida (white plague type II), Serratia marcescens (white pox), Vibrio coralliilyticus, and V. shiloi (bacteria-induced bleaching). Growth of A. coralicida and V. shiloi was slightly stimulated by dust extracts from Mali and USVI, respectively, but unaffected by extracts from the other dust sources. Lag time to the start of log-growth phase was significantly shortened for A. coralicida when dosed with dust extracts from Mali and USVI. Growth of S. marcescens and V. coralliilyticus was neither stimulated nor inhibited by any of the dust extracts. This study demonstrates that constituents from atmospheric dust can alter growth of recognized coral disease pathogens under laboratory conditions.
Detection of Organophosphate Flame Retardants in Furniture Foam and US House Dust
Stapleton, Heather M.; Klosterhaus, Susan; Eagle, Sarah; Fuh, Jennifer; Meeker, John D.; Blum, Arlene; Webster, Thomas F.
2009-01-01
Restrictions on the use of polybrominated diphenyl ethers (PBDEs) have resulted in the increased use of alternate flame retardant chemicals to meet flammability standards. However, it has been difficult to determine which chemical formulations are currently being used in high volumes to meet flammability standards since the use of flame retardant formulations in consumer products is not transparent (i.e. not provided to customers). To investigate chemicals being used as replacements for PentaBDE in polyurethane foam, we analyzed foam samples from 26 different pieces of furniture purchased in the United States primarily between 2003 and 2009 using gas chromatography mass spectrometry. Samples included foam from couches, chairs, mattress pads, pillows, and, in one case, foam from a sound proofing system of a laboratory grade dust sieve. Fifteen of the foam samples contained the flame retardant tris(1,3-dichloro-2-propyl) phosphate (TDCPP; 1–5% by weight), four samples contained tris(1-chloro-2-propyl) phosphate (TCPP; 0.5 –2.2 % by weight), one sample contained brominated chemicals found in a new flame retardant mixture called Firemaster 550 (4.2% by weight), and one foam sample collected from a futon likely purchased prior to 2004 contained PentaBDE (0.5% by weight). Due to the high frequency of detection of the chlorinated phosphate compounds in furniture foam, we analyzed extracts from 50 house dust samples collected between 2002 and 2007 in the Boston, MA area for TDCPP, TCPP, and another high volume use organophosphate-based flame retardant used in foam, triphenylphosphate (TPP). Detection frequencies for TDCPP and TPP in the dust samples were >96% and were log normally distributed, similar to observations for PBDEs. TCPP was positively detected in dust in only 24% of the samples, but detection was significantly limited by a co-elution problem. The geometric mean concentrations for TCPP, TDCPP and TPP in house dust were 570, 1890, and 7360 ng/g, respectively, and maximum values detected in dust were 5490, 56,080 and 1,798,000 ng/g, respectively. These data suggest that levels of these organophosphate flame retardants are comparable, or in some cases, greater than, levels of PBDEs in house dust. The high prevalence of these chemicals in foam and the high concentrations measured in dust (as high as 1.8 mg/g), warrant further studies to evaluate potential health effects from dust exposure, particularly for children. PMID:19848166
FLOOR PLAN OF MAIN PROCESSING BUILDING (CPP601), FIRST FLOOR SHOWING ...
FLOOR PLAN OF MAIN PROCESSING BUILDING (CPP-601), FIRST FLOOR SHOWING SAMPLE CORRIDORS AND EIGHTEEN CELLS AND ADJOINING REMOTE ANALYTICAL FACILITY (CPP-627) SHOWING REMOTE ANALYTICAL FACILITIES LAB, DECONTAMINATION ROOM, AND MULTICURIE CELL ROOM. TO LEFT ARE LABORATORY BUILDING (CPP-602) AND MAINTENANCE BUILDING (CPP-630). INL DRAWING NUMBER 200-0601-00-706-051979. ALTERNATE ID NUMBER CPP-E-1979. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
Maki, Teruya; Kurosaki, Yasunori; Onishi, Kazunari; Lee, Kevin C; Pointing, Stephen B; Jugder, Dulam; Yamanaka, Norikazu; Hasegawa, Hiroshi; Shinoda, Masato
2017-01-01
Asian dust events transport the airborne bacteria in Chinese desert regions as well as mineral particles and influence downwind area varying biological ecosystems and climate changes. However, the airborne bacterial dynamics were rarely investigated in the Gobi desert area, where dust events are highly frequent. In this study, air samplings were sequentially performed at a 2-m high above the ground at the sampling site located in desert area (Tsogt-Ovoo of Gobi desert; Mongolia 44.2304°N, 105.1700°E). During the dust event days, the bacterial cells and mineral particles increased to more than tenfold of concentrations. MiSeq sequencing targeting 16S ribosomal DNA revealed that the airborne bacteria in desert area mainly belonged to the classes Acidobacteria , Actinobacteria , Bacteroidetes , Chloroflexi , Bacilli , Alpha-proteobacteria , Beta-proteobacteria , and Gamma-proteobacteria. The bacterial community structures were different between dust events and non-dust events. The air samples collected at the dust events indicated high abundance rates of Alpha-proteobacteria , which were reported to dominate on the leaf surfaces of plants or in the saline lake environments. After the dust events, the members of Firmicutes ( Bacilli ) and Bacteroidetes , which are known to form endospore and attach with coarse particles, respectively, increased their relative abundances in the air samples. Presumably, the bacterial compositions and diversities in atmosphere significantly vary during dust events, which carry some particles from grassland (phyllo-sphere), dry lake, and sand surfaces, as well as some bacterial populations such as Firmicutes and Bacteroidetes maintain in the atmosphere for longer time.
Ward, Mary H.; Bell, Erin M.; Whitehead, Todd P.; Gunier, Robert B.; Friesen, Melissa C.; Nuckols, John R.
2013-01-01
Background: Residential pesticide exposure has been linked to adverse health outcomes in adults and children. High-quality exposure estimates are critical for confirming these associations. Past epidemiologic studies have used one measurement of pesticide concentrations in carpet dust to characterize an individual’s average long-term exposure. If concentrations vary over time, this approach could substantially misclassify exposure and attenuate risk estimates. Objectives: We assessed the repeatability of pesticide concentrations in carpet dust samples and the potential attenuation bias in epidemiologic studies relying on one sample. Methods: We collected repeated carpet dust samples (median = 3; range, 1–7) from 21 homes in Fresno County, California, during 2003–2005. Dust was analyzed for 13 pesticides using gas chromatography–mass spectrometry. We used mixed-effects models to estimate between- and within-home variance. For each pesticide, we computed intraclass correlation coefficients (ICCs) and the estimated attenuation of regression coefficients in a hypothetical case–control study collecting a single dust sample. Results: The median ICC was 0.73 (range, 0.37–0.95), demonstrating higher between-home than within-home variability for most pesticides. The expected magnitude of attenuation bias associated with using a single dust sample was estimated to be ≤ 30% for 7 of the 13 compounds evaluated. Conclusions: For several pesticides studied, use of one dust sample to represent an exposure period of approximately 2 years would not be expected to substantially attenuate odds ratios. Further study is needed to determine if our findings hold for longer exposure periods and for other pesticides. PMID:23462689
Determining the spatial variability of personal sampler inlet locations.
Vinson, Robert; Volkwein, Jon; McWilliams, Linda
2007-09-01
This article examines the spatial variability of dust concentrations within a coal miner's breathing zone and the impact of sampling location at the cap lamp, nose, and lapel. Tests were conducted in the National Institute for Safety and Health Pittsburgh Research Laboratory full-scale, continuous miner gallery using three prototype personal dust monitors (PDM). The dust masses detected by the PDMs were used to calculate the percentage difference of dust mass between the cap lamp and the nose and between the lapel and the nose. The calculated percentage differences of the masses ranged from plus 12% to minus 25%. Breathing zone tests were also conducted in four underground coal mines using the torso of a mannequin to simulate a miner. Coal mine dust was sampled with multi-cyclone sampling cans mounted directly in front of the mannequin near the cap lamp, nose, and lapel. These four coal mine tests found that the spatial variability of dust levels and imprecision of the current personal sampler is a greater influence than the sampler location within the breathing zone. However, a one-sample t-test of this data did find that the overall mean value of the cap lamp/nose ratio was not significantly different than 1 (p-value = 0.21). However, when applied to the overall mean value of the lapel/nose ratio there was a significant difference from 1 (p-value < .0001). This finding is important because the lapel has always been the sampling location for coal mine dust samples. But these results suggest that the cap location is slightly more indicative of what is breathed through the nose area.
Jílková, Veronika; Picek, Tomáš; Šestauberová, Martina; Krištůfek, Václav; Cajthaml, Tomáš; Frouz, Jan
2016-10-01
We compared methane (CH4) and carbon dioxide (CO2) fluxes in samples collected from the aboveground parts of wood ant nests and in the organic and mineral layer of the surrounding forest floor. Gas fluxes were measured during a laboratory incubation, and microbial properties (abundance of fungi, bacteria and methanotrophic bacteria) and nutrient contents (total and available carbon and nitrogen) were also determined. Both CO2 and CH4 were produced from ant nest samples, indicating that the aboveground parts of wood ant nests act as sources of both gases; in comparison, the forest floor produced about four times less CO2 and consumed rather than produced CH4 Fluxes of CH4 and CO2 were positively correlated with contents of available carbon and nitrogen. The methanotrophic community was represented by type II methanotrophic bacteria, but their abundance did not explain CH4 flux. Fungal abundance was greater in ant nest samples than in forest floor samples, but bacterial abundance was similar in both kinds of samples, suggesting that the organic materials in the nests may have been too recalcitrant for bacteria to decompose. The results indicate that the aboveground parts of wood ant nests are hot spots of CO2 and CH4 production in the forest floor. © FEMS 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Stipe, Christopher B.; Miller, Arthur L.; Brown, Jonathan; Guevara, Edward; Cauda, Emanuele
2015-01-01
Airborne silica dust (quartz) is common in coal mines and represents a respiratory hazard that can lead to silicosis, a potentially fatal lung disease. With an eye toward developing a portable monitoring device for rapid analysis of silica dust, laser-induced breakdown spectroscopy (LIBS) was used to quantify quartz in coal dust samples collected on filter media. Pure silica (Min-U-Sil™ 5), Georgia kaolin, and Pittsburgh-4 and Illinois-6 coal dusts were deposited separately and at multiple mass loadings onto 37-mm polyvinylchloride (PVC) filters. LIBS-generated silicon emission was monitored at 288.16 nm, and non-silica contributions to that signal from kaolinite were removed by simultaneously detecting aluminum. Measurements of the four samples were used to calculate limits of detection (LOD) for silicon and aluminum of approximately 0.08 µg/cm2 and 0.05 µg/cm2, respectively (corresponding to 0.16 µg/cm2 and 0.20 µg/cm2 for silica and kaolinite, respectively). Relative errors of prediction are around 10%. Results demonstrate that LIBS can dependably quantify silica on filter samples of coal dust and confirm that accurate quantification can be achieved for very lightly loaded samples, which supports the potential application of LIBS for rapid, in-field monitoring. PMID:23146184
Stipe, Christopher B; Miller, Arthur L; Brown, Jonathan; Guevara, Edward; Cauda, Emanuele
2012-11-01
Airborne silica dust (quartz) is common in coal mines and represents a respiratory hazard that can lead to silicosis, a potentially fatal lung disease. With an eye toward developing a portable monitoring device for rapid analysis of silica dust, laser-induced breakdown spectroscopy (LIBS) was used to quantify quartz in coal dust samples collected on filter media. Pure silica (Min-U-Sil™ 5), Georgia kaolin, and Pittsburgh-4 and Illinois-6 coal dusts were deposited separately and at multiple mass loadings onto 37-mm polyvinylchloride (PVC) filters. LIBS-generated silicon emission was monitored at 288.16 nm, and non-silica contributions to that signal from kaolinite were removed by simultaneously detecting aluminum. Measurements of the four samples were used to calculate limits of detection (LOD) for silicon and aluminum of approximately 0.08 μg/cm(2) and 0.05 μg/cm(2), respectively (corresponding to 0.16 μg/cm(2) and 0.20 μg/cm(2) for silica and kaolinite, respectively). Relative errors of prediction are around 10%. Results demonstrate that LIBS can dependably quantify silica on filter samples of coal dust and confirm that accurate quantification can be achieved for very lightly loaded samples, which supports the potential application of LIBS for rapid, in-field monitoring.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Herich, Hanna; Tritscher, Torsten; Wiacek, Aldona
2009-11-01
Airborne mineral dust particles serve as cloud condensation nuclei (CCN), thereby influencing the formation and properties of warm clouds. It is therefore of particular interest how dust aerosols with different mineralogy behave when exposed to high relative humidity (RH) or supersaturation with respect to liquid water similar to atmospheric conditions. In this study the sub-saturated hygroscopic growth and the supersaturated cloud condensation nucleus activity of pure clays and real desert dust aerosols was determined using a hygroscopicity tandem differential mobility analyzer (HTDMA) and a cloud condensation nuclei counter (CCNC), respectively. Five different illite, montmorillonite and kaolinite clay samples as wellmore » as three desert dust samples (Saharan dust (SD), Chinese dust (CD) and Arizona test dust (ATD)) were used. Aerosols were generated both with a wet and a dry disperser and the water uptake was parameterized via the hygroscopicity parameter, κ. The hygroscopicity of dry generated dust aerosols was found to be negligible when compared to processed atmospheric aerosols, with CCNC derived κ values between 0.00 and 0.02. The latter value can be idealized as a particle consisting of 96.7% (by volume) insoluble material and ~3.3% ammonium sulfate. Pure clay aerosols were found to be generally less hygroscopic than real desert dust particles. All illite and montmorillonite samples had κ~0.003, kaolinites were least hygroscopic and had κ=0.001. SD (κ=0.023) was found to be the most hygroscopic dry-generated desert dust followed by CD (κ=0.007) and ATD (κ=0.003). Wet-generated dust showed an increased water uptake when compared to dry-generated samples. This is considered to be an artifact introduced by redistribution of soluble material between the particles while immersed in an aqueous medium during atomization, thus indicating that specification of the generation method is critically important when presenting such data. Any atmospheric processing of fresh mineral dust which leads to the addition of more than ~3% soluble material is expected to significantly enhance hygroscopicity and CCN activity.« less
Permissible Exposure Level for Lunar Dusts: Gaps are Closing
NASA Technical Reports Server (NTRS)
James, John T.; Lam, Chiu-Wing; Scully Robert; Santana, Patricia; Cooper, Bonnie; McKay, David; Zeidler-Erdely, Patti C.; Castranova, Vincent
2010-01-01
Space faring nations plan to return human explorers to the moon within the next decade. Experience during the Apollo flights suggests that lunar dust will invariably get into the habitat where the finest portion (less than 5 micrometers) could be inhaled by the crew before it is cleared from the atmosphere. NASA is developing a database from which a 6-month, episodic exposure standard for lunar dust can be set. Three kinds of moon dust were prepared from a parent sample of Apollo 14 regolith #14003,96. Our goal was to prepare each type of dust sample with a mean diameter less than 2 m, which is suitable for instillation into the lungs of rats. The three samples were prepared as follows: separation from the parent sample using a fluidized bed, grinding using a jet mill grinder, or grinding with a ball-mill grinder. Grinding simulated restoration of surface activation of dust expected to occur at the surface of the moon on native lunar dust. We used two grinding methods because they seemed to produce different modes of activation. The effects of grinding were preserved by maintaining the dust in ultra-pure nitrogen until immediately before it was placed in suspension for administration to rats. The dust was suspended in physiological saline with 10% Survanta, a lung surfactant. Rats were given intratrachael instillations of the dust suspension at three doses. In addition to the three moon dusts (A, C and E), we instilled the same amount of a negative control (TiO2, B) and a highly-toxic, positive control (quartz, D). These additional mineral dusts were selected because they have well-established and very different permissible exposure levels (PELs). Our goal was to determine where lunar dusts fit between these extremes, and then estimate a PEL for each lunar dust. We evaluated many indices of toxicity to the lung. The figure shows the changes in lactate dehydrogenase (LDH), a marker of cell death, for the five dusts. Benchmark dose software (Version 2.1.2) from the Environmental Protection Agency was used to estimate the 10% effect levels (BMD(sub 10)) using five models. The best-fitting model was used to estimate the optimal BMD(sub 10) (table)
Witt, Emitt C; Wronkiewicz, David J; Shi, Honglan
2013-01-01
Fugitive road dust collection for chemical analysis and interpretation has been limited by the quantity and representativeness of samples. Traditional methods of fugitive dust collection generally focus on point-collections that limit data interpretation to a small area or require the investigator to make gross assumptions about the origin of the sample collected. These collection methods often produce a limited quantity of sample that may hinder efforts to characterize the samples by multiple geochemical techniques, preserve a reference archive, and provide a spatially integrated characterization of the road dust health hazard. To achieve a "better sampling" for fugitive road dust studies, a cyclonic fugitive dust (CFD) sampler was constructed and tested. Through repeated and identical sample collection routes at two collection heights (50.8 and 88.9 cm above the road surface), the products of the CFD sampler were characterized using particle size and chemical analysis. The average particle size collected by the cyclone was 17.9 μm, whereas particles collected by a secondary filter were 0.625 μm. No significant difference was observed between the two sample heights tested and duplicates collected at the same height; however, greater sample quantity was achieved at 50.8 cm above the road surface than at 88.9 cm. The cyclone effectively removed 94% of the particles >1 μm, which substantially reduced the loading on the secondary filter used to collect the finer particles; therefore, suction is maintained for longer periods of time, allowing for an average sample collection rate of about 2 g mi. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.
The episodic influx of tin-rich cosmic dust particles during the last ice age
NASA Astrophysics Data System (ADS)
LaViolette, Paul A.
2015-12-01
This paper presents evidence of the first detection of interstellar dust in ice age polar ice. Neutron activation analysis (NAA) results are reported for 15 elements found in dust filtered from eight samples of Camp Century Greenland ice dating from 40 to 78 kyrs BP. High concentrations of Sn, Sb, Au, Ag, Ir, and Ni were found to be present in three out of these eight samples. One compositionally anomalous dust sample from an ice core depth of 1230.5 m (age ∼49 kyrs BP, near the beginning of D/O stadial No. 13) was found to contain tin with an average weight percent of 49% as determined by energy dispersive X-ray analysis (EDS). This sample was also found to contain high concentrations of Pb with an average weight abundance of 8.4% and matching the Sn:Pb ratio observed in interstellar spectra. Dust particles in this sample generally have a platy morphology and range from submicron size up to a size as large as 120 μm, a particle consisting almost entirely of SnO2 and being the largest monomineralic extraterrestrial dust particle so far discovered. One porous aggregate tin-bearing particle was found to contain nanometer sized chondrules indicating an extraterrestrial origin. The extraterrestrial origin for the tin is also indicated by the presence of isotopic anomalies in the 114Sn, 115Sn and 117Sn isotopes. Follow up isotopic measurements of this tin-rich dust need to be performed to improve confidence in the anomalies reported here. High abundances of the low melting point elements Ag, Au, and Sb are also present in this tin-rich sample along with elevated abundances of the siderophiles Ir, Ni, Fe, and Co, the latter being present in chondritic proportions and indicating that about 9% of the dust has a C1 chondrite component. Measurements indicate that about 97% of this dust is of extraterrestrial origin with a 3% residual being composed of terrestrial windblown dust. EDS analysis of another tin-rich Camp Century ice core dust sample dating to ∼130 kyrs BP was found to contain tin-rich particles with a similar platy morphology and to have Sn and Pb weight abundances averaging 39% and 7.5% respectively, again approximating the interstellar Sn:Pb ratio. The relative absence of cosmic microspheres and the unmelted appearance of the tin-rich particles in both of these samples suggests that these particles entered the Earth's atmosphere at low velocity, implicating a gradual accumulation of dust from a dispersed state in the near Earth space environment. The unusual enhancement of Sn and Pb could be explained if these dust particles were originally present in the solar system's interstellar environment in a superconducting native metal state and were preferentially concentrated through Meissner effect forces by the passage of cosmic ray driven hydromagnetic shocks which may also have transported them into the solar system. The 49 kyrs BP event is estimated to have lasted over 6 years and to have deposited dust onto the Earth at a rate 104-105 times higher than present rates. This had a significant cooling effect on climate and resulted in a transient 33 fold increase in snow accumulation. Future discovery of these events in ice cores at other locations should void any lingering thoughts that this heavy metal enhancement may be due to sample contamination.
Li, Junqi; Dong, Zheng; Wang, Ying; Bao, Junsong; Yan, Yijun; Liu, Anming; Jin, Jun
2018-08-01
Brominated flame retardants (BFRs) can accumulate in humans and are associated with adverse health effects. The study was conducted to determine the differences in Polybrominated diphenyl ethers (PBDEs) and alternative brominated flame retardant (Alt-BFR) concentrations between men and women. We analyzed hair samples from 14 male and 20 female university students, paired dust samples from their dormitories (10 for males and 8 for females), and six dust samples from university teaching buildings. The total PBDE concentrations in hair from females were significantly (three times) higher (p = 0.012) than that from males (means 372 and 109 ng/g, respectively). The mean total PBDE concentrations in classroom and dormitory dust were 36100 and 2012 ng/g, respectively. The PBDE patterns were different in the male and female hair samples, as were the patterns in the classroom and dormitory dust. There are no reports concerning human exposure to BFRs through dust that was assessed considering academic and residential environments simultaneously. The differences between BFR exposure for males and females and the differences between BFR concentrations in hair samples from males and females were consistent for 71.4% of the compounds. However, using only dormitory dust in the calculations gave consistent differences only for 28.6% of the compounds, suggesting that the BFR concentration differences in hair were mainly because females spent much more time than males in classrooms. Copyright © 2018 Elsevier Ltd. All rights reserved.
Residential metal contamination and potential health risks of ...
Potosí, Bolivia, is the site of centuries of historic and present-day mining of the Cerro Rico Mountain, known for its rich polymetallic deposits, and was the site of large-scale Colonial era silver refining operations, both of which have left a legacy of pollution. In this study, trace elements were quantified in adobe brick, dirt floor, and surface dust samples from 49 houses. Mean concentrations of total mercury (Hg), lead (Pb), and arsenic (As) were statistically significantly greater than concentrations measured in Sucre, Bolivia, a non-mining town used as a reference site, and exceeded US-based soil screening levels that are designed to be protective of human health. Adobe brick samples were analyzed for bioaccessible concentrations of elements using a simulated gastric fluid (GF) extraction. Mean GF extractable concentrations of Hg, As, and Pb were 0.841, 14.9, and 30.2 percent of the total concentration, respectively. Total and GF extractable concentrations of these elements were used to estimate exposure and potential health risks to children following incidental ingestion of adobe brick particles. Risks were assessed using a range of potential ingestion rates (50-1000 mg/day). Although the majority of households have total Hg, As, and Pb concentrations that represent a potential health risk, fewer are of concern when GF extractable concentrations are considered at lower ingestion rates. For Hg, only a small percentage of the sampled houses have GF ex
[Health risk assessment of heavy metals in atmospheric dust of Qingdao City].
Zhang, Chun-Rong; Wu, Zheng-Long; Yao, Chun-Hui; Gao, Zong-Jun
2014-07-01
Based on the 89 atmospheric dust samples and soil samples that were collected around Qingdao, we tested and analyzed the contents of Cd, Cr, Cu, Hg, Ni, Pb, Zn. Based on these analysis results, the risk of heavy metals in atmospheric dusts to human health were assessed by using the US EPA Health Risk Assessment Model. Analysis showed that the average contents of Cd, Cr, Cu, Hg, Pb, Zn in the atmospheric dust of Shinan, Shibei and Laoshan districts were the highest. Therefore, the air pollution of these districts was more serious than the districts of Licang, Chengyang and Huangdao. Comparing the average contents of heavy metals in atmospheric dust with those in soil, we found that only the content of Hg in atmospheric dust collected from the districts of Shinan, Shibei and Laoshan was lower than that in the corresponding soil. All the contents of other heavy metals in atmospheric dust were higher than those in corresponding soil. As a whole, the heavy metals in atmospheric dust of Qingdao City showed slight difference and were less harmful to human health. However, it was harmful in some samples to human health if the contents of Cr and Pb in atmospheric dusts of Shinan, Laoshan and Chengyang districts were always kept at such high densities. Besides, the accumulation of heavy metals in atmospheric dust through various approaches and categories may obviously increase the risk of damaging human health.
Treated and untreated rock dust: Quartz content and physical characterization.
Soo, Jhy-Charm; Lee, Taekhee; Chisholm, William P; Farcas, Daniel; Schwegler-Berry, Diane; Harper, Martin
2016-11-01
Rock dusting is used to prevent secondary explosions in coal mines, but inhalation of rock dusts can be hazardous if the crystalline silica (e.g., quartz) content in the respirable fraction is high. The objective of this study is to assess the quartz content and physical characteristics of four selected rock dusts, consisting of limestone or marble in both treated (such as treatment with stearic acid or stearates) and untreated forms. Four selected rock dusts (an untreated and treated limestone and an untreated and treated marble) were aerosolized in an aerosol chamber. Respirable size-selective sampling was conducted along with particle size-segregated sampling using a Micro-Orifice Uniform Deposit Impactor. Fourier Transform Infrared spectroscopy and scanning electron microscopy with energy-dispersive X-ray (SEM-EDX) analyses were used to determine quartz mass and particle morphology, respectively. Quartz percentage in the respirable dust fraction of untreated and treated forms of the limestone dust was significantly higher than in bulk samples, but since the bulk percentage was low the enrichment factor would not have resulted in any major change to conclusions regarding the contribution of respirable rock dust to the overall airborne quartz concentration. The quartz percentage in the marble dust (untreated and treated) was very low and the respirable fractions showed no enrichment. The spectra from SEM-EDX analysis for all materials were predominantly from calcium carbonate, clay, and gypsum particles. No free quartz particles were observed. The four rock dusts used in this study are representative of those presented for use in rock dusting, but the conclusions may not be applicable to all available materials.
Pfister, Hugo; Morzadec, Claudie; Le Cann, Pierre; Madec, Laurent; Lecureur, Valérie; Chouvet, Martine; Jouneau, Stéphane; Vernhet, Laurent
2017-10-01
Dairy working increases the prevalence of lower airway respiratory diseases, especially COPD and asthma. Epidemiological studies have reported that chronic inhalation of organic dusts released during specific daily tasks could represent a major risk factor for development of these pathologies in dairy workers. Knowledge on size, nature and biological activity of such organic dusts remain however limited. To compare size distribution, microbial composition and cellular effects of dusts liberated by the spreading of straw bedding in five French dairy farms located in Brittany. Mechanized distribution of straw bedding generated a cloud of inhalable dusts in the five dairy farms' barns. Thoracic particles having a 3-7.5µm size constituted 58.9-68.3% of these dusts. Analyses of thoracic dusts by next generation sequencing showed that the microbial dust composition differed between the five French farms, although Actinobacteria, Bacteroidetes, Firmicutes and Proteobacteria represent more than 97.5% of the bacterial phyla detected in each sample. Several bacteria genera comprising of human pathogenic species, such as Pseudomonas, Staphylococcus, Thermoactinomyces or Saccharopolyspora were identified. Cladosporium and Alternaria fungal genera, which are potent environmental determinants of respiratory symptoms, were detected in dusts collected in the five farms and their levels reached 15.5-51.1% and 9-24.7% of assignable fungal sequences in each sample, respectively. Finally, all dust samples significantly and strongly increased the expression of the pro-inflammatory TNF-α, IL-1β, IL-6 and IL-8 cytokines at both mRNA and protein levels in human monocyte-derived macrophages. Their effects were dose-dependent and detectable from 1µg/ml. The intensity of the macrophage responses however differed according to the samples. Our results strengthen the hypothesis that organic dusts released during the distribution of straw bedding are mainly constituted of thoracic particles which are small enough to deposit on lower bronchial epithelium of dairy farmers and induce inflammation. Copyright © 2017 Elsevier Inc. All rights reserved.
Multidisciplinary studies of the dust storm that affected Sydney in September 2009
NASA Astrophysics Data System (ADS)
De Deckker, P.
2012-04-01
A major dust storm transgressed over southeastern Australia in September 2009 and continued as far as northern Queensland [to the north], New Zealand and New Caledonia [to the east] . We analysed samples of the dust for organic compounds, its microbiological composition, pollen, trace and rare earth elements as well as Sr and Nd isotopes. Grain size analysis was also performed on some of the samples. We also obtained information on the meteorological conditions that led to the large dust plume and its pathway. Our geochemical fingerprinting allowed us to determine the origin of the dust, and this was confirmed by meteorological observations and satellite imagery. As the pathway of the dust plume went over the city of Canberra, located to the southwest of Sydney, we were able to collect samples of dust that fell with rain, and the surprise was that the geochemical composition of the dust varied with time [and dust fall], identifying that as the dust plume transgressed over the landscape, it picked up additional material that was compositionally different from its point of origin. We also compared our data with those obtained from another major dust event that affected Canberra in October 2002, and a number of important differences are noted, particularly with respect of the microbiological composition of the dust, and its chemical composition. Collaborators on this project are: Chris Munday and Gwen Allison [microbiology]: Research School of Biology, ANU; Jochen Brocks and Janet Hope [organic chemistry] and Marc Norman [inorganic geochemistry]: Research School of Earth Sciences, ANU; Tadhg O'Loingsigh and Nigel Tapper [meteorology, satellite imagery] and Sander van der Kaars [palynology]: Geography and Environmental Science, Monash University; and J.-B. Stuut [grain size analysis], NIOZ.
2017-03-22
Hellas is an ancient impact structure and is the deepest and broadest enclosed basin on Mars. It measures about 2,300 kilometers across and the floor of the basin, Hellas Planitia, contains the lowest elevations on Mars. The Hellas region can often be difficult to view from orbit due to seasonal frost, water-ice clouds and dust storms, yet this region is intriguing because of its diverse, and oftentimes bizarre, landforms. This image from eastern Hellas Planitia shows some of the unusual features on the basin floor. These relatively flat-lying "cells" appear to have concentric layers or bands, similar to a honeycomb. This "honeycomb" terrain exists elsewhere in Hellas, but the geologic process responsible for creating these features remains unresolved. The map is projected here at a scale of 50 centimeters (19.7 inches) per pixel. [The original image scale is 52.2 centimeters (20.6 inches) per pixel (with 2 x 2 binning); objects on the order of 157 centimeters (61.8 inches) across are resolved.] North is up. http://photojournal.jpl.nasa.gov/catalog/PIA21570
Fluorescence detection of protein content in house dust: the possible role of keratin.
Voloshina, O V; Shirshin, E A; Lademann, J; Fadeev, V V; Darvin, M E
2017-03-01
We propose a fluorescence method for protein content assessment in fine house dust, which can be used as an indicator of the hygienic state of occupied rooms. The results of the measurements performed with 30 house dust samples, including ultrafiltration experiments, strongly suggest that the fluorescence emission of house dust extracts excited at 350 nm is mainly due to protein fragments, which are presumably keratin hydrolysates. This suggestion is supported by several facts: (i) Spectral band shapes for all the samples under investigation are close and correspond to that of keratin; (ii) fluorescence intensity correlates with the total protein content as provided by Lowry assay; (iii) treatment of the samples with proteinase K, which induces keratin hydrolysis, results in fluorescence enhancement without changing fluorescence band shape; and (iv) Raman spectra of keratin and fine house dust samples exhibit a very similar structure. Based on the obtained results and literature data, we propose a hypothesis that keratin is a major substrate for fluorescence species in fine house dust, which are responsible for emission at 350-nm excitation. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Allergens in Urban Schools and Homes of Children with Asthma
Permaul, Perdita; Hoffman, Elaine B.; Fu, Chunxia; Sheehan, William J.; Baxi, Sachin N.; Gaffin, Jonathan M.; Lane, Jeffrey P.; Bailey, Ann; King, Eva; Chapman, Martin D.; Gold, Diane R.; Phipatanakul, Wanda
2012-01-01
Background Most studies of indoor allergens have focused on the home environment. However, schools may be an important site of allergen exposure for children with asthma. We compared school allergen exposure to home exposure in a cohort of children with asthma. Correlations between settled dust and airborne allergen levels in classrooms were examined. Methods Settled dust and airborne samples from 12 inner-city schools were analyzed for indoor allergens using multiplex array technology (MARIA). School samples were linked to students with asthma enrolled in the School Inner-City Asthma Study (SICAS). Settled dust samples from students’ bedrooms were analyzed similarly. Results From schools, 229 settled dust and 197 airborne samples were obtained. From homes, 118 settled dust samples were obtained. Linear mixed regression models of log-transformed variables showed significantly higher settled dust levels of mouse, cat and dog allergens in schools than homes (545% higher for Mus m 1, estimated absolute difference 0.55 μg/g, p<0.0001; 198% higher for Fel d 1, estimated absolute difference 0.13 μg/g, p=0.0033; and 144% higher for Can f 1, estimated absolute difference 0.05 μg/g, p=0.0008). Airborne and settled dust Mus m 1 levels in classrooms were moderately correlated (r=0.48; p< 0.0001). There were undetectable to very low levels of cockroach and dust mite allergens in both homes and schools. Conclusions Mouse allergen levels in schools were substantial. In general, cat and dog allergen levels were low, but detectable, and were higher in schools. Aerosolization of mouse allergen in classrooms may be a significant exposure for students. Further studies are needed to evaluate the effect of indoor allergen exposure in schools on asthma morbidity in students with asthma. PMID:22672325
NASA Astrophysics Data System (ADS)
Kumar, P.; Sokolik, I. N.; Nenes, A.
2011-04-01
This study reports laboratory measurements of particle size distributions, cloud condensation nuclei (CCN) activity, and droplet activation kinetics of wet generated aerosols from clays, calcite, quartz, and desert soil samples from Northern Africa, East Asia/China, and Northern America. The dependence of critical supersaturation, sc, on particle dry diameter, Ddry, is used to characterize particle-water interactions and assess the ability of Frenkel-Halsey-Hill adsorption activation theory (FHH-AT) and Köhler theory (KT) to describe the CCN activity of the considered samples. Regional dust samples produce unimodal size distributions with particle sizes as small as 40 nm, CCN activation consistent with KT, and exhibit hygroscopicity similar to inorganic salts. Clays and minerals produce a bimodal size distribution; the CCN activity of the smaller mode is consistent with KT, while the larger mode is less hydrophilic, follows activation by FHH-AT, and displays almost identical CCN activity to dry generated dust. Ion Chromatography (IC) analysis performed on regional dust samples indicates a soluble fraction that cannot explain the CCN activity of dry or wet generated dust. A mass balance and hygroscopicity closure suggests that the small amount of ions (of low solubility compounds like calcite) present in the dry dust dissolve in the aqueous suspension during the wet generation process and give rise to the observed small hygroscopic mode. Overall these results identify an artifact that may question the atmospheric relevance of dust CCN activity studies using the wet generation method. Based on a threshold droplet growth analysis, wet generated mineral aerosols display similar activation kinetics compared to ammonium sulfate calibration aerosol. Finally, a unified CCN activity framework that accounts for concurrent effects of solute and adsorption is developed to describe the CCN activity of aged or hygroscopic dusts.
Viegas, Susana; Caetano, Liliana Aranha; Korkalainen, Merja; Faria, Tiago; Pacífico, Cátia; Carolino, Elisabete; Quintal Gomes, Anita; Viegas, Carla
2017-01-01
Organic dust and related microbial exposures are the main inducers of several respiratory symptoms. Occupational exposure to organic dust is very common and has been reported in diverse settings. In vitro tests using relevant cell cultures can be very useful for characterizing the toxicity of complex mixtures present in the air of occupational environments such as organic dust. In this study, the cell viability and the inflammatory response, as measured by the production of pro-inflammatory cytokines tumor necrosis factor-α (TNFα) and interleukin-1 β (IL-1β), were determined in human macrophages derived from THP-1 monocytic cells. These cells were exposed to air samples from five occupational settings known to possess high levels of contamination of organic dust: poultry and swine feed industries, waste sorting, poultry production and slaughterhouses. Additionally, fungi and particle contamination of those settings was studied to better characterize the organic dust composition. All air samples collected from the assessed workplaces caused both cytotoxic and pro-inflammatory effects. The highest responses were observed in the feed industry, particularly in swine feed production. This study emphasizes the importance of measuring the organic dust/mixture effects in occupational settings and suggests that differences in the organic dust content may result in differences in health effects for exposed workers. PMID:29051440
NASA Astrophysics Data System (ADS)
Kutuzov, S.; Shahgedanova, M.; Mikhalenko, V.; Ginot, P.; Lavrentiev, I.; Popov, G.
2013-12-01
We present a study of dust deposition events and its physical and chemical characteristics in Caucasus Mountains as documented by snow and firn pack at Mt Elbrus. Dust samples were collected from the shallow ice cores and snow pits in 2009-2013 at the western Elbrus plateau (5150 m a.s.l.). Particle size distribution and chemical analysis (major ions, trace elements) were completed for each sample using Coulter Counter Multisizer III, scanning electron microscopy (SEM), IC and ICPMS analysis. It was shown that desert dust deposition occurred in Caucasus 4-8 times a year and originates from the Northern Sahara and the deserts of the Middle East. Analysis of volumetric particle size distributions showed that the modal values ranged between 2 μm and 4 μm although most samples were characterised by modal values of 2.0-2.8 μm with an average of 2.6 μm. These values are lower than those obtained from the ice cores in central and southern Asia following the deposition of long-travelled dust and are closer to those reported for the European Alps and the polar ice cores. All samples containing dust have a single mode which is usually interpreted as a single source region. They do not reveal any significant differences between the Saharan and the Middle Eastern sources. The annual average dust mass concentrations were 10-15 mg kg-1 which is higher than the average concentrations reported for other mountain regions and this was strongly affected by dust deposition events. The deposition of dust resulted in elevated concentrations of most ions, especially Ca2+, Mg2+, K+, and sulphates. Dust originated from multiple sources in the Middle East including Mesopotamia or passing over the Middle East was characterised by the elevated concentrations of nitrates and ammonia which is related to a high atmospheric loads of ammonium emitted by agricultural sources and high concentrations of ammonium in dust originating from this region. By contrast, samples of the Saharan dust showed low concentrations consistent with the low ammonium loads in the source region. . The research leading to these results has received funding from the European Union Seventh Framework Programme FP7-PEOPLE-2010-IIF under grant agreement PIIF-GA-2010-275071 Russian Foundation for Basic Research (grants 11-05-00304 and 13-05-10069).
NASA Astrophysics Data System (ADS)
Mohammad, R.; Ramsey, M.; Scheidt, S. P.
2010-12-01
Prior to mineral dust deposition affecting albedo, aerosols can have direct and indirect effects on local to regional scale climate by changing both the shortwave and longwave radiative forcing. In addition, mineral dust causes health hazards, such as respiratory-related illnesses and deaths, loss of agricultural soil, and safety hazards to aviation and motorists due to reduced visibility. Previous work utilized satellite and ground-based TIR data to describe the direct longwave radiative effect of the Saharan Air Layer (SAL) over the Atlantic Ocean originating from dust storms in the Western Sahara. TIR emission spectroscopy was used to identify the spectral absorption features of that dust. The current research focuses on Kuwait and utilizes a comprehensive set of spatial, analytical and geological tools to characterize dust emissions and its radiative effects. Surface mineral composition maps for the Kuwait region were created using ASTER images and GIS datasets in order to identify the possible sources of wind-blown dust. Backward trajectory analysis using the Hybrid Single-Particle Lagrangian Integrated Trajectory (HYSPLIT) model suggests the dust source areas were located in Iraq, Syria, Jordan and Saudi Arabia. Samples collected from two dust storms (May and July 2010) were analyzed for their mineral composition and to validate the dust source areas identified by the modeling and remote sensing analysis. These air fall dust samples were collected in glass containers on a 13 meter high rooftop in the suburb of Rumaithiya in Kuwait. Additional samples will be collected to expand the analysis and their chemical compositions will be characterized by a combination of laboratory X-ray fluorescence (XRF), Scanning Electron Microscopy (SEM) and TIR emission spectroscopy. The overarching objective of this ongoing research is to both characterize the effects of mineral dust on climate as well as establish a predictive tool that can identify dust storm sources and potentially aid in establishing a more accurate prediction and warning system in the Middle East region.
Robert W. Peck; Christine G. Niwa
2005-01-01
Microarthropod densities within late-successional coniferous forests thinned 16-41 yr before sampling were compared with adjacent unthinned stands to identify longer term effects of thinning on this community. Soil and forest floor layers were sampled separately on eight paired sites. Within the forest floor oribatid, mesostigmatid, and to a marginal extent,...
Gutierrez, Benjamin T.; Butman, Bradford; Blackwood, Dann S.
2001-01-01
This CD-ROM contains photographs and sediment sample analyses of the sea floor obtained at 142 sites in western Massachusetts Bay (Figure 1) during a research cruise (USGS cruise ISBL99024) aboard the Fishing Vessel (FV) Isabel S. (Figure 2) conducted July 18-21, 1999. These photographs and samples provide critical ground truth information for the interpretation of shaded relief and backscatter intensity maps created using data collected with a multibeam echo sounder system (Butman and others, in press, a, b, c; Valentine and others, in press, a, b, c). Collection of these photographs and samples was undertaken in support of a large project whose overall objective is to map and describe the sea floor of Massachusetts Bay.
NASA Astrophysics Data System (ADS)
Raack, J.; Dennis, R.; Balme, M. R.; Taj-Eddine, K.; Ori, G. G.
2017-12-01
Dust devils are small vertical convective vortices which occur on Earth and Mars [1] but their internal structure is almost unknown. Here we report on in situ samples of two active dust devils in the Sahara Desert in southern Morocco [2]. For the sampling we used a 4 m high aluminium pipe with sampling areas made of removable adhesive tape. We took samples between 0.1-4 m with a sampling interval of 0.5 m and between 0.5-2 m with an interval of 0.25 m, respectively. The maximum diameter of all particles of the different sampling heights were then measured using an optical microscope to gain vertical grain size distributions and relative particle loads. Our measurements imply that both dust devils have a general comparable internal structure despite their different strengths and dimensions which indicates that the dust devils probably represents the surficial grain size distribution they move over. The particle sizes within the dust devils decrease nearly exponential with height which is comparable to results by [3]. Furthermore, our results show that about 80-90 % of the total particle load were lifted only within the first meter, which is a direct evidence for the existence of a sand skirt. If we assume that grains with a diameter <31 μm can go into suspension [4], our results show that only less than 0.1 wt% can be entrained into the atmosphere. Although this amount seems very low, these values represent between 60 and 70 % of all lifted particles due to the small grain sizes and their low weight. On Mars, the amount of lifted particles will be general higher as the dust coverage is larger [5], although the atmosphere can only suspend smaller grain sizes ( <20 μm) [6] compared to Earth. During our field campaign we observed numerous larger dust devils each day which were up to several hundred meters tall and had diameters of several tens of meters. This implies a much higher input of fine grained material into the atmosphere (which will have an influence on the climate, weather, and human health [7]) compared to the relative small dust devils sampled during our field campaign. [1] Thomas and Gierasch (1985) Science 230 [2] Raack et al. (2017) Astrobiology [3] Oke et al. (2007) J. Arid Environ. 71 [4] Balme and Greeley (2006) Rev. Geophys. 44 [5] Christensen (1986) JGR 91 [6] Newman et al. (2002) JGR 107 [7] Gillette and Sinclair (1990) Atmos. Environ. 24
Channel at Night in Thermal Infrared
NASA Technical Reports Server (NTRS)
2002-01-01
This nighttime thermal infrared image, taken by the thermal emission imaging system on NASA's 2001 Mars Odyssey spacecraft, shows differences in temperature that are due to differences in the abundance of rocks, sand and dust on the surface. Rocks remain warm at night, as seen in the warm (bright) rim of the five kilometer (three mile) diameter crater located on the right of this image.The sinuous channel floor is cold, suggesting that it is covered by material that is more finely grained than the surrounding plains. The interior of the crater shows a great deal of thermal structure, indicating that the distribution of rocks, sand and dust varies across the floor.The presence of rocks on the rim and inner wall indicates that this crater maintains some of its original character, despite erosion and deposition by Martian winds. Nighttime infrared images such as this one will greatly aid in mapping the physical properties of Mars' surface.This image is centered at 2 degrees north, 0.4 degrees west, and was acquired at about 3:15 a.m. local Martian time. North is to the right of the image.NASA's Jet Propulsion Laboratory manages the 2001 Mars Odyssey mission for NASA's Office of Space Science, Washington, D.C. The thermal emission imaging system was provided by Arizona State University, Tempe. Lockheed Martin Astronautics, Denver, is the prime contractor for the project, and developed and built the orbiter. Mission operations are conducted jointly from Lockheed Martin and from JPL, a division of the California Institute of Technology in Pasadena.Resuspension of biological particles from indoor surfaces: Effects of humidity and air swirl.
Salimifard, Parichehr; Rim, Donghyun; Gomes, Carlos; Kremer, Paul; Freihaut, James D
2017-04-01
Human exposure to airborne particles can lead to adverse health outcomes such as respiratory and allergic symptoms. Understanding the transport mechanism of respirable particles in occupied spaces is a first step towards assessing inhalation exposure. Several studies have contributed to the current knowledge of particle resuspension from indoor surfaces; however, few published studies are available on resuspension of biological particles from indoor surfaces. The objective of this study is to investigate the impacts of humidity and air swirl on resuspension of biological particles from floor and duct surfaces. Controlled laboratory experiments were conducted under varying degrees of humidity and airflow conditions. Resuspension rates of five types of particles (quartz, dust mite, cat fur, dog fur, and bacterial spore-Bacillus thuringiensis as an anthrax simulant) were determined for two types of floor surface (carpet and linoleum) and a duct surface (galvanized sheet metal). The results show that the particle property of being hydrophilic or hydrophobic plays an important role in particle resuspension rate. Resuspension rates of hydrophilic dust mite particles increase up to two orders of magnitude as relative humidity (RH) decreased from 80% to 10% at 25°C. However, resuspension rates of cat fur and dog fur particles that are hydrophobic are within the measurement error range (±15%) over 10-80% RH. With regard to resuspension of bacterial spores (Bacillus thuringiensis) from a duct surface, the resuspension rates are substantially affected by air swirl velocity and particle size. However, no discernible increase in particle resuspension was observed with duct vibration. Copyright © 2017 Elsevier B.V. All rights reserved.
Comet coma sample return instrument
NASA Technical Reports Server (NTRS)
Albee, A. L.; Brownlee, Don E.; Burnett, Donald S.; Tsou, Peter; Uesugi, K. T.
1994-01-01
The sample collection technology and instrument concept for the Sample of Comet Coma Earth Return Mission (SOCCER) are described. The scientific goals of this Flyby Sample Return are to return to coma dust and volatile samples from a known comet source, which will permit accurate elemental and isotopic measurements for thousands of individual solid particles and volatiles, detailed analysis of the dust structure, morphology, and mineralogy of the intact samples, and identification of the biogenic elements or compounds in the solid and volatile samples. Having these intact samples, morphologic, petrographic, and phase structural features can be determined. Information on dust particle size, shape, and density can be ascertained by analyzing penetration holes and tracks in the capture medium. Time and spatial data of dust capture will provide understanding of the flux dynamics of the coma and the jets. Additional information will include the identification of cosmic ray tracks in the cometary grains, which can provide a particle's process history and perhaps even the age of the comet. The measurements will be made with the same equipment used for studying micrometeorites for decades past; hence, the results can be directly compared without extrapolation or modification. The data will provide a powerful and direct technique for comparing the cometary samples with all known types of meteorites and interplanetary dust. This sample collection system will provide the first sample return from a specifically identified primitive body and will allow, for the first time, a direct method of matching meteoritic materials captured on Earth with known parent bodies.
Environmental urban lead exposure and blood lead levels in children of Mexico City.
Romieu, I; Carreon, T; Lopez, L; Palazuelos, E; Rios, C; Manuel, Y; Hernandez-Avila, M
1995-01-01
Lead contamination is now a leading public health problem in Mexico. However, there are few data on the lead content of various environmental sources, and little is known about the contribution of these sources to the total lead exposure in the population of children residing in Mexico City. We conducted a cross-sectional study in a random sample of 200 children younger than 5 years of age who lived in one of two areas of Mexico City. Environmental samples of floor, window, and street dust, paint, soil, water, and glazed ceramics were obtained from the participants' households, as well as blood samples and dirt from the hands of the children. Blood lead levels ranged from 1 to 31 micrograms/dl with a mean of 9.9 micrograms/dl (SD 5.8 micrograms/dl). Forty-four percent of the children 18 months of age or older had blood lead levels exceeding 10 micrograms/dl. The lead content of environmental samples was low, except in glazed ceramic. The major predictors of blood lead levels were the lead content of the glazed ceramics used to prepare children's food, exposure to airborne lead due to vehicular emission, and the lead content of the dirt from the children's hands. We conclude that the major sources of lead exposure in Mexico City could be controlled by adequate public health programs to reinforce the use of unleaded gasoline and to encourage production and use of unleaded cookware instead of lead-glazed ceramics. PMID:8605853
Hanson, Blake; Zhou, Yanjiao; Bautista, Eddy J; Urch, Bruce; Speck, Mary; Silverman, Frances; Muilenberg, Michael; Phipatanakul, Wanda; Weinstock, George; Sodergren, Erica; Gold, Diane R; Sordillo, Joanne E
2016-06-15
Environmental microbes have been associated with both protective and adverse health effects in children and adults. Epidemiological studies often rely on broad biomarkers of microbial exposure (i.e. endotoxin, 1 → 3-beta-d-glucan), but fail to identify the taxonomic composition of the microbial community. Our aim was to characterize the bacterial and fungal microbiome in different types of environmental samples collected in studies of human health effects. We determined the composition of microbial communities present in home, school and outdoor air samples by amplifying and sequencing regions of rRNA genes from bacteria (16S) and fungi (18S and ITS). Samples for this pilot study included indoor settled dust (from both a Boston area birth cohort study on Home Allergens and Asthma (HAA) (n = 12) and a study of school exposures and asthma symptoms (SICAS) (n = 1)), as well as fine and coarse concentrated outdoor ambient particulate (CAP) samples (n = 9). Sequencing of amplified 16S, 18S, and ITS regions was performed on the Roche-454 Life Sciences Titanium pyrosequencing platform. Indoor dust samples were dominated by Gram-positive bacteria (Firmicutes and Actinobacteria); the most abundant bacterial genera were those related to human flora (Streptococcus, Staphylococcus, Corynebacterium and Lactobacillus). Outdoor CAPs were dominated by Gram-negative Proteobacteria from water and soil sources, in particular the genera Acidovorax, and Brevundimonas (which were present at very low levels or entirely absent in indoor dust). Phylum-level fungal distributions identified by 18S or ITS regions showed very similar findings: a predominance of Ascomycota in indoor dust and Basidiomycota in outdoor CAPs. ITS sequencing of fungal genera in indoor dust showed significant proportions of Aureobasidium and Leptosphaerulina along with some contribution from Cryptococcus, Epicoccum, Aspergillus and the human commensal Malassezia. ITS sequencing detected more than 70 fungal genera in indoor dust not observed by culture. Microbiome sequencing is feasible for different types of archived environmental samples (indoor dust, and low biomass air particulate samples), and offers the potential to study how whole communities of microbes (including unculturable taxa) influence human health.
Hanson, Blake; Zhou, Yanjiao; Bautista, Eddy J.; Urch, Bruce; Speck, Mary; Silverman, Frances; Muilenberg, Michael; Phipatanakul, Wanda; Weinstock, George; Sodergren, Erica; Gold, Diane R.; Sordillo, Joanne E.
2016-01-01
Environmental microbes have been associated with both protective and adverse health effects in children and adults. Epidemiological studies often rely on broad biomarkers of microbial exposure (i.e. endotoxin, 1→3, Beta-D glucan), but fail to identify the taxonomic composition of the microbial community. Our aim was to characterize the bacterial and fungal microbiome in different types of environmental samples collected in studies of human health effects. We determined the composition of microbial communities present in home, school and outdoor air samples by amplifying and sequencing regions of rRNA genes from bacteria (16S) and fungi (18S and ITS). Samples for this pilot study included indoor settled dust (from both a Boston area birth cohort study on Home Allergens and Asthma (HAA)(n=12) and a study of school exposures and asthma symptoms (SICAS) (n=1)), as well as fine and coarse concentrated outdoor ambient particulate (CAP) samples (n=9). Sequencing of amplified 16S, 18S, and ITS regions was performed on the Roche-454 Life Sciences Titanium pyrosequencing platform. Indoor dust samples were dominated by gram-positive bacteria (Firmicutes and Actinobacteria); the most abundant bacterial genera were those related to human flora (Streptococcus, Staphylococcus, Corynebacterium and Lactobacillus). Outdoor CAPs were dominated by gram-negative Proteobacteria from water and soil sources, in particular the genera Acidovorax, and Brevundimonas (which were present at very low levels or entirely absent in indoor dust). Phylum-level fungal distributions identified by 18S or ITS regions showed very similar findings: a predominance of Ascomycota in indoor dust and Basidiomycota in outdoor CAPs. ITS sequencing of fungal genera in indoor dust showed significant proportions of Aureobasidium and Leptosphaerulina along with some contribution from Cryptococcus, Epicoccum, Aspergillus and the human commensal Malassezia. ITS sequencing detected an additional 70 fungal genera in indoor dust not observed by culture. Microbiome sequencing is feasible for different types of archived environmental samples (indoor dust, and low biomass air particulate samples), and offers the potential to study how whole communities of microbes (including unculturable taxa) influence human health. PMID:27213188
Van Metre, Peter C.; Mahler, Barbara J.; Wilson, Jennifer T.; Burbank, Teresa L.
2008-01-01
Parking lots and driveways are dominant features of the modern urban landscape, and in the United States, sealcoat is widely used on these surfaces. One of the most widely used types of sealcoat contains refined coal tar; coal-tar-based sealcoat products have a mean polycyclic aromatic hydrocarbon (PAH) concentration of about 5 percent. A previous study reported that parking lots in Austin, Texas, treated with coal-tar sealcoat were a major source of PAH compounds in streams. This report presents methods for and data from the analysis of concentrations of PAH compounds in dust from sealed and unsealed pavement from nine U.S. cities, and concentrations of PAH compounds in other related solid materials (sealcoat surface scrapings, nearby street dust, and nearby soil) from three of those same cities and a 10th city. Dust samples were collected by sweeping dust from areas of several square meters with a soft nylon brush into a dustpan. Some samples were from individual lots or driveways, and some samples consisted of approximately equal amounts of material from three lots. Samples were sieved to remove coarse sand and gravel and analyzed by gas chromatography/mass spectrometry. Concentrations of PAHs vary greatly among samples with total PAH (sigmaPAH), the sum of 12 unsubstituted parent PAHs, ranging from nondetection for all 12 PAHs (several samples from Portland, Oregon, and Seattle, Washington; sigmaPAH of less than 36,000 micrograms per kilogram) to 19,000,000 micrograms per kilogram for a sealcoat scraping sample (Milwaukee, Wisconsin). The largest PAH concentrations in dust are from a driveway sample from suburban Chicago, Illinois (sigmaPAH of 9,600,000 micrograms per kilogram).
Higashisaka, Kazuma; Fujimura, Maho; Taira, Mayu; Yoshida, Tokuyuki; Tsunoda, Shin-ichi; Baba, Takashi; Yamaguchi, Nobuyasu; Nabeshi, Hiromi; Yoshikawa, Tomoaki; Nasu, Masao; Tsutsumi, Yasuo
2014-01-01
Asian dust is a springtime meteorological phenomenon that originates in the deserts of China and Mongolia. The dust is carried by prevailing winds across East Asia where it causes serious health problems. Most of the information available on the impact of Asian dust on human health is based on epidemiological investigations, so from a biological standpoint little is known of its effects. To clarify the effects of Asian dust on human health, it is essential to assess inflammatory responses to the dust and to evaluate the involvement of these responses in the pathogenesis or aggravation of disease. Here, we investigated the induction of inflammatory responses by Asian dust particles in macrophages. Treatment with Asian dust particles induced greater production of inflammatory cytokines interleukin-6 and tumor necrosis factor-α (TNF-α) compared with treatment with soil dust. Furthermore, a soil dust sample containing only particles ≤10 μm in diameter provoked a greater inflammatory response than soil dust samples containing particles >10 μm. In addition, Asian dust particles-induced TNF-α production was dependent on endocytosis, the production of reactive oxygen species, and the activation of nuclear factor-κB and mitogen-activated protein kinases. Together, these results suggest that Asian dust particles induce inflammatory disease through the activation of macrophages. PMID:24987712
NASA Astrophysics Data System (ADS)
Clark, Christopher Jonathan Redfern
2015-04-01
Using multiwavelength observations, centred around the unique far-infrared and submillimetre window provided by the Herschel Space Observatory, this thesis investigates the origins and evolution of cosmic dust in the local Universe - by examining individual sources of dust in our own galaxy, and by studying dust in nearby galaxies. I search Herschel observations of the remnants of Kepler’s (SN1604) and Tycho’s (SN1572) supernovæ, both Type-Ia explosions, for evidence of dust creation by these events. Being the only Type-Ia supernovæ known to have occurred in our Galaxy within the past 1,000 years, these remnants are the only ones both close enough to resolve, and young enough that they are dominated by their ejecta dynamics. There is no indication of any recently manufactured dust associated with either supernova remnant. It therefore appears that Type-Ia supernovæ do not contribute significantly to the dust budgets of galaxies. The Crab Nebula, the result of a Type-II supernova (SN1054), is also investigated using Herschel and multiwavelength data. After accounting for other sources of emission, a temperature of Td = 63.1 K and mass of Md = 0.21 M⊙ is derived for the Crab Nebula’s dust component. I create a map of the distribution of dust in the Crab Nebula, the first of its kind, by means of a resolved component separation, revealing that the dust is located in the dense filamentary ejecta. We can be confident that this dust will survive in the long term, and be injected into the galactic dust budget. This is the first detection of manufactured supernova dust for which this can be said. Next I use the Herschel-ATLAS to assemble HAPLESS: the Herschel- ATLAS Phase-1 Limited Extent Spatial Sample - a blind, volume-limited, dust- selected sample of nearby galaxies. The majority of this sample is made up of curious very blue galaxies. Often irregular and/or flocculent in morphology, with extremely blue UV-NIR colours, these galaxies appear to be prominent in the local dusty universe. In the absence of reliable photometry for the HAPLESS galaxies, I describe the function and testing of a purpose-built photometric pipeline - CAAPR: Chris’ Adequate Aperture Photometry Routine. The photometry conducted with CAAPR exhibits flux greater by factors of, on average, 1.6 in the FUV and 1.4 in r-band, relative to the previously-available photometry. In comparison to other surveys of dust in local galaxies, the HAPLESS systems show a strong propensity towards very late morphological types and extremely blue FUV-Ks colours. The dust in the HAPLESS galaxies appears to be very cold, with a median temperature of 14.6 K. They are also exceptionally dust rich, with a median dust mass of 5.3 × 106 M(_{\\odot}) , and a median Md/M(_{\\star}) of 4.4×10-3 - greater by a factor of 1.8-3.7 than that seen in other local surveys. The curious very blue HAPLESS galaxies, whilst accounting for only 6% of the stellar mass in our sample, contain over 35% of the dust mass. I show that the more dust-rich a galaxy (as defined by Md/M(_{\\star})), the smaller the fraction of its UV luminosity that suffers dust absorption - this effect is observed to be particularly dramatic in the case of the curious very blue objects. Either the emissivity or geometry of the dust in these systems must be highly unusual. HAPLESS suggests a dust mass volume density of the local universe of (3.7 ± 0.7) × 105 M(_{\\odot}) Mpc-3; the largest value reported to date. The HAPLESS 250 μm luminosity function is in good agreement with surveys of far larger volumes, suggesting that we do not sample an over-dense region of space. The HAPLESS galaxies are extraordinarily gas rich; the median HAPLESS gas fraction is 0.52, and 19% of the sample have gas fractions >0.8. The median HAPLESS gas-to-dust ratio is ≍260, 2-3 times larger than in other local surveys. The very blue galaxies of the sample are found to be particularly gas rich; a chemical and dust evolution model indicates that they are at an early stage of converting their gas into stars. A dust-selected survey such as H-ATLAS is a particularly efficient way of identifying young systems of this kind, which should therefore provide valuable insights into the chemical evolution of young galaxies.
Mugford, Christopher; Boylstein, Randy; Gibbs, Jenna L
2017-01-01
In 1974, the National Institute for Occupational Safety and Health recommended a ban on the use of silica sand abrasives containing >1% silica due to the risk of silicosis. This gave rise to substitutes including coal slag. An Occupational Safety and Health Administration investigation in 2010 uncovered a case cluster of suspected pneumoconiosis in four former workers at a coal slag processing facility in Illinois, possibly attributable to occupational exposure to coal slag dust. This article presents the results from a National Institute for Occupational Safety and Health industrial hygiene survey at the same coal slag processing facility and a second facility. The industrial hygiene survey consisted of the collection of: a) bulk samples of unprocessed coal slag, finished granule product, and settled dust for metals and silica; b) full-shift area air samples for dust, metals, and crystalline silica; and c) full-shift personal air samples for dust, metals, and crystalline silica. Bulk samples consisted mainly of iron, manganese, titanium, and vanadium. Some samples had detectable levels of arsenic, beryllium, cadmium, and cobalt. Unprocessed coal slags from Illinois and Kentucky contained 0.43–0.48% (4,300–4,800 mg/kg) silica. Full-shift area air samples identified elevated total dust levels in the screen (2–38 mg/m3) and bag house (21 mg/m3) areas. Full-shift area air samples identified beryllium, chromium, cobalt, copper, iron, nickel, manganese, and vanadium. Overall, personal air samples for total and respirable dust (0.1–6.6 mg/m3 total; and 0.1–0.4 mg/m3 respirable) were lower than area air samples. All full-shift personal air samples for metals and silica were below published occupational exposure limits. All bulk samples of finished product granules contained less than 1% silica, supporting the claim coal slag may present less risk for silicosis than silica sand. We note that the results presented here are solely from two coal slag processing facilities, and more in-depth air monitoring is needed to better characterize occupational exposure to coal slag dust, metals, and silica at similar facilities. PMID:27808662
Mugford, Christopher; Boylstein, Randy; Gibbs, Jenna L
2017-05-01
In 1974, the National Institute for Occupational Safety and Health recommended a ban on the use of silica sand abrasives containing >1% silica due to the risk of silicosis. This gave rise to substitutes including coal slag. An Occupational Safety and Health Administration investigation in 2010 uncovered a case cluster of suspected pneumoconiosis in four former workers at a coal slag processing facility in Illinois, possibly attributable to occupational exposure to coal slag dust. This article presents the results from a National Institute for Occupational Safety and Health industrial hygiene survey at the same coal slag processing facility and a second facility. The industrial hygiene survey consisted of the collection of: (a) bulk samples of unprocessed coal slag, finished granule product, and settled dust for metals and silica; (b) full-shift area air samples for dust, metals, and crystalline silica; and (c) full-shift personal air samples for dust, metals, and crystalline silica. Bulk samples consisted mainly of iron, manganese, titanium, and vanadium. Some samples had detectable levels of arsenic, beryllium, cadmium, and cobalt. Unprocessed coal slags from Illinois and Kentucky contained 0.43-0.48% (4,300-4,800 mg/kg) silica. Full-shift area air samples identified elevated total dust levels in the screen (2-38 mg/m 3 ) and bag house (21 mg/m 3 ) areas. Full-shift area air samples identified beryllium, chromium, cobalt, copper, iron, nickel, manganese, and vanadium. Overall, personal air samples for total and respirable dust (0.1-6.6 mg/m 3 total; and 0.1-0.4 mg/m 3 respirable) were lower than area air samples. All full-shift personal air samples for metals and silica were below published occupational exposure limits. All bulk samples of finished product granules contained less than 1% silica, supporting the claim coal slag may present less risk for silicosis than silica sand. We note that the results presented here are solely from two coal slag processing facilities, and more in-depth air monitoring is needed to better characterize occupational exposure to coal slag dust, metals, and silica at similar facilities.
Gaspar, Fraser W; Chevrier, Jonathan; Bornman, Riana; Crause, Madelein; Obida, Muvhulawa; Barr, Dana Boyd; Bradman, Asa; Bouwman, Henk; Eskenazi, Brenda
2015-12-01
Although approximately 123 million people may be exposed to high levels of insecticides through the use of indoor residual spraying (IRS) for malaria control, few studies exist on indoor insecticide contamination due to IRS and its relationship with human exposure. In the present study, we developed a sampling method to collect undisturbed dust from 50 homes in Limpopo, South Africa, a region where dichlorodiphenyltrichloroethane (DDT) has been used in IRS programs to prevent malaria for ~70years. We quantified DDT and its degradation products, dichlorodiphenyldichloroethylene (DDE), and dichlorodiphenyldichloroethane (DDD) in dust samples to determine dust loading levels and compared these levels to paired serum concentrations of p,p'-DDT and p,p'-DDE in women residents. p,p'-DDT and p,p'-DDE had the highest detection frequencies in both dust (58% and 34% detection, respectively) and serum samples (98% and 100% detection, respectively). Significantly higher detection frequencies for o,p'-DDT, p,p'-DDE, and p,p'-DDD were observed in dust samples collected in buildings that had been previously sprayed for malaria control. We also observed a significant, positive association between dust loading and serum concentrations of p,p'-DDT and p,p'-DDE (Spearman's rho=0.68 and 0.54, respectively). Despite the low detection frequency in dust, our results indicate that undisturbed dust may be a good metric to quantify long-term home exposure to DDT-related compounds and that contamination of the home environment may be an important determinant/source of DDT and DDE exposure. Copyright © 2015 Elsevier Ltd. All rights reserved.
Scattering Properties of Large Irregular Cosmic Dust Particles at Visible Wavelengths
DOE Office of Scientific and Technical Information (OSTI.GOV)
Escobar-Cerezo, J.; Palmer, C.; Muñoz, O.
The effect of internal inhomogeneities and surface roughness on the scattering behavior of large cosmic dust particles is studied by comparing model simulations with laboratory measurements. The present work shows the results of an attempt to model a dust sample measured in the laboratory with simulations performed by a ray-optics model code. We consider this dust sample as a good analogue for interplanetary and interstellar dust as it shares its refractive index with known materials in these media. Several sensitivity tests have been performed for both structural cases (internal inclusions and surface roughness). Three different samples have been selected tomore » mimic inclusion/coating inhomogeneities: two measured scattering matrices of hematite and white clay, and a simulated matrix for water ice. These three matrices are selected to cover a wide range of imaginary refractive indices. The selection of these materials also seeks to study astrophysical environments of interest such as Mars, where hematite and clays have been detected, and comets. Based on the results of the sensitivity tests shown in this work, we perform calculations for a size distribution of a silicate-type host particle model with inclusions and surface roughness to reproduce the experimental measurements of a dust sample. The model fits the measurements quite well, proving that surface roughness and internal structure play a role in the scattering pattern of irregular cosmic dust particles.« less
Infrared Luminosities and Dust Properties of z ≈ 2 Dust-obscured Galaxies
NASA Astrophysics Data System (ADS)
Bussmann, R. S.; Dey, Arjun; Borys, C.; Desai, V.; Jannuzi, B. T.; Le Floc'h, E.; Melbourne, J.; Sheth, K.; Soifer, B. T.
2009-11-01
We present SHARC-II 350 μm imaging of twelve 24 μm bright (F 24 μm > 0.8 mJy) Dust-Obscured Galaxies (DOGs) and Combined Array for Research in Millimeter-wave Astronomy (CARMA) 1 mm imaging of a subset of two DOGs. These objects are selected from the Boötes field of the NOAO Deep Wide-Field Survey. Detections of four DOGs at 350 μm imply infrared (IR) luminosities which are consistent to within a factor of 2 of expectations based on a warm-dust spectral energy distribution (SED) scaled to the observed 24 μm flux density. The 350 μm upper limits for the 8 non-detected DOGs are consistent with both Mrk 231 and M82 (warm-dust SEDs), but exclude cold dust (Arp 220) SEDs. The two DOGs targeted at 1 mm were not detected in our CARMA observations, placing strong constraints on the dust temperature: T dust > 35-60 K. Assuming these dust properties apply to the entire sample, we find dust masses of ≈3 × 108 M sun. In comparison to other dusty z ~ 2 galaxy populations such as submillimeter galaxies (SMGs) and other Spitzer-selected high-redshift sources, this sample of DOGs has higher IR luminosities (2 × 1013 L sun versus 6 × 1012 L sun for the other galaxy populations) that are driven by warmer dust temperatures (>35-60 K versus ~30 K) and lower inferred dust masses (3 × 108 M sun versus 3 × 109 M sun). Wide-field Herschel and Submillimeter Common-User Bolometer Array-2 surveys should be able to detect hundreds of these power-law-dominated DOGs. We use the existing Hubble Space Telescope and Spitzer/InfraRed Array Camera data to estimate stellar masses of these sources and find that the stellar to gas mass ratio may be higher in our 24 μm bright sample of DOGs than in SMGs and other Spitzer-selected sources. Although much larger sample sizes are needed to provide a definitive conclusion, the data are consistent with an evolutionary trend in which the formation of massive galaxies at z ~ 2 involves a submillimeter bright, cold-dust, and star-formation-dominated phase followed by a 24 μm bright, warm-dust and AGN-dominated phase.
The Herschel Virgo Cluster Survey. XIII. Dust in early-type galaxies
NASA Astrophysics Data System (ADS)
di Serego Alighieri, S.; Bianchi, S.; Pappalardo, C.; Zibetti, S.; Auld, R.; Baes, M.; Bendo, G.; Corbelli, E.; Davies, J. I.; Davis, T.; De Looze, I.; Fritz, J.; Gavazzi, G.; Giovanardi, C.; Grossi, M.; Hunt, L. K.; Magrini, L.; Pierini, D.; Xilouris, E. M.
2013-04-01
Aims: We study the dust content of a large optical input sample of 910 early-type galaxies (ETG) in the Virgo cluster, also extending to the dwarf ETG, and examine the results in relation to those on the other cold ISM components. Methods: We have searched for far-infrared emission in all galaxies in the input sample using the 250 μm image of the Herschel Virgo Cluster Survey (HeViCS). This image covers a large fraction of the cluster with an area of ~55 square degrees. For the detected ETG we measured fluxes in five bands from 100 to 500 μm, and estimated the dust mass and temperature with modified black-body fits. Results: Dust is detected above the completeness limit of 25.4 mJy at 250 μm in 46 ETG, 43 of which are in the optically complete part of the input sample. In addition, dust is present at fainter levels in another six ETG. We detect dust in the four ETG with synchrotron emission, including M 87. Dust appears to be much more concentrated than stars and more luminous ETG have higher dust temperatures. Considering only the optically complete input sample and correcting for the contamination by background galaxies, dust detection rates down to the 25.4 mJy limit are 17% for ellipticals, about 40% for lenticulars (S0 + S0a), and around 3% for dwarf ETG. Dust mass does not correlate clearly with stellar mass and is often much greater than expected for a passive galaxy in a closed-box model. The dust-to-stars mass ratio anticorrelates with galaxy luminosity, and for some dwarf ETG reaches values as high as for dusty late-type galaxies. In the Virgo cluster slow rotators appear more likely to contain dust than fast ones. Comparing the dust results with those on Hi there are only eight ETG detected both in dust and in Hi in the HeViCS area; 39 have dust but only an upper limit on Hi, and eight have Hi but only an upper limit on dust. The locations of these galaxies in the cluster are different, with the dusty ETG concentrated in the densest regions, while the Hi rich ETG are at the periphery. Herschel is an ESA space observatory with science instruments provided by European-led Principal Investigator consortia and with important participation from NASA.Table A.1 is available in electronic form at http://www.aanda.org
30 CFR 90.210 - Respirable dust samples; report to operator.
Code of Federal Regulations, 2010 CFR
2010-07-01
... MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-COAL MINERS WHO HAVE EVIDENCE OF THE DEVELOPMENT OF PNEUMOCONIOSIS Sampling Procedures § 90.210 Respirable dust samples; report to operator. (a) The Secretary shall... for voiding any samples; and, (7) The Social Security Number of the part 90 miner. (b) Upon receipt...
Shin, Hyeong-Moo; McKone, Thomas E.; Nishioka, Marcia G.; Fallin, M. Daniele; Croen, Lisa A.; Hertz-Picciotto, Irva; Newschaffer, Craig J.; Bennett, Deborah H.
2014-01-01
Consumer products and building materials emit a number of semivolatile organic compounds (SVOCs) in the indoor environment. Because indoor SVOCs accumulate in dust, we explore the use of dust to determine source strength and report here on analysis of dust samples collected in 30 U.S. homes for six phthalates, four personal care product ingredients, and five flame retardants. We then use a fugacity-based indoor mass-balance model to estimate the whole house emission rates of SVOCs that would account for the measured dust concentrations. Di-2-ethylhexyl phthalate (DEHP) and di-iso-nonyl phthalate (DiNP) were the most abundant compounds in these dust samples. On the other hand, the estimated emission rate of diethyl phthalate (DEP) is the largest among phthalates, although its dust concentration is over two orders of magnitude smaller than DEHP and DiNP. The magnitude of the estimated emission rate that corresponds to the measured dust concentration is found to be inversely correlated with the vapor pressure of the compound, indicating that dust concentrations alone cannot be used to determine which compounds have the greatest emission rates. The combined dust-assay modeling approach shows promise for estimating indoor emission rates for SVOCs. PMID:24118221
Pulmonary Toxicity Studies of Lunar Dusts in Rodents
NASA Technical Reports Server (NTRS)
Lam, Chiu-wing; James, John T.; Taylor, Larry
2008-01-01
NASA will build an outpost on the lunar surface for long-duration human habitation and research. The surface of the Moon is covered by a layer of fine, reactive dust, and the living quarters in the lunar outpost are expected to be contaminated by lunar dust. NASA established the Lunar Airborne Dust Toxicity Advisory Group (LADTAG) to evaluate the risk of exposure to the dust and to establish safe exposure limits for astronauts working in the lunar habitat. Because the toxicity of lunar dust is not known, LADTAG has recommended investigating its toxicity in the lungs of laboratory animals. After receiving this recommendation, NASA directed the JSC Toxicology Laboratory to determine the pulmonary toxicity of lunar dust in exposed rodents. The rodent pulmonary toxicity studies proposed here are the same as those proposed by the LADTAG. Studies of the pulmonary toxicity of a dust are generally done first in rodents by intratracheal instillation (ITI). This toxicity screening test is then followed by an inhalation study, which requires much more of the test dust and is labor intensive. We succeeded in completing an ITI study on JSC-1 lunar dust simulant in mice (Lam et al., Inhalation Toxicology 14:901-916, 2002, and Inhalation Toxicology 14: 917-928, 2002), and have conducted a pilot ITI study to examine the acute toxicity of an Apollo lunar (highland) dust sample. Preliminary results obtained by examining lung lavage fluid from dust-treated mice show that lunar dust was somewhat toxic (more toxic than TiO2, but less than quartz dust). More extensive studies have been planned to further examine lung lavage fluid for biomarkers of toxicity and lung tissues for histopathological lesions in rodents exposed to aged and activated lunar dust samples. In these studies, reference dusts (TiO2 and quartz) of known toxicities and have industrial exposure limits will be studied in parallel so the relative toxicity of lunar dust can be determined. The ITI results will also be useful for choosing an exposure concentration for the animal inhalation study on a selected lunar dust sample, which is included as a part of this proposal. The animal inhalation exposure will be conducted with lunar dust simulant prior to the study with the lunar dust. The simulant exposure will ensure that the study techniques used with actual lunar dust will be successful. The results of ITI and inhalation studies will reveal the toxicological risk of exposures and are essential for setting exposure limits on lunar dust for astronauts living in the lunar habitat.
The effect of ozonization on furniture dust: microbial content and immunotoxicity in vitro.
Huttunen, Kati; Kauhanen, Eeva; Meklin, Teija; Vepsäläinen, Asko; Hirvonen, Maija-Riitta; Hyvärinen, Anne; Nevalainen, Aino
2010-05-01
Moisture and mold problems in buildings contaminate also the furniture and other movable property. If cleaning of the contaminated furniture is neglected, it may continue to cause problems to the occupants even after the moisture-damage repairs. The aim of this study was to determine the effectiveness of high-efficiency ozone treatment in cleaning of the furniture from moisture-damaged buildings. In addition, the effectiveness of two cleaning methods was compared. Samples were vacuumed from the padded areas before and after the treatment. The microbial flora and concentrations in the dust sample were determined by quantitative cultivation and QPCR-methods. The immunotoxic potential of the dust samples was analyzed by measuring effects on cell viability and production of inflammatory mediators in vitro. Concentrations of viable microbes decreased significantly in most of the samples after cleaning. Cleaning with combined steam wash and ozonisation was more effective method than ozonising alone, but the difference was not statistically significant. Detection of fungal species with PCR showed a slight but nonsignificant decrease in concentrations after the cleaning. The immunotoxic potential of the collected dust decreased significantly in most of the samples. However, in a small subgroup of samples, increased concentrations of microbes and immunotoxicological activity were detected. This study shows that a transportable cleaning unit with high-efficiency ozonising is in most cases effective in decreasing the concentrations of viable microbes and immunotoxicological activity of the furniture dust. However, the method does not destroy or remove all fungal material present in the dust, as detected with QPCR analysis, and in some cases the cleaning procedure may increase the microbial concentrations and immunotoxicity of the dust. Copyright 2010 Elsevier B.V. All rights reserved.
Application of a Permethrin Immunosorbent Assay Method to Residential Soil and Dust Samples
A low-cost, high throughput bioanalytical screening method was developed for monitoring cis/trans-permethrin in dust and soil samples. The method consisted of a simple sample preparation procedure [sonication with dichloromethane followed by a solvent exchange into methanol:wate...
Occurrence of indoor allergens in Saudi Arabia
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sorensen, H.; Gravesen, S.; Lind, P.
1985-06-01
Investigations on indoor airborne allergens in Saudi Arabia were performed by mold cultures and dust analyses by counter-current immunoelectrophoresis. Twenty fungal genera were isolated, with Aspergillus as the most often encountered. Most of the dust-bound fungi found are ubiquitous and common. Antibodies against Dermatophagoides pteronyssinus, cat- cow- and rat dander, and Cynodon dactylon pollen were used in the dust analyses. Animal antigens were found in five of the ten dust samples. House dust mites were extraordinarily rare. Pollen of Cynodon dactylon (Bermuda grass) was present in nearly all the samples, and in a concurrent clinical study this antigen was foundmore » to be the most common cause of perennial rhinitis.« less
NASA Technical Reports Server (NTRS)
Westphal, A. J.; Allen, C.; Bajit, S.; Bastien, R.; Bechtel, H.; Bleuet, P.; Borg, J.; Brenker, F.; Bridges, J.; Brownlee, D. E.;
2010-01-01
In January 2006, the Stardust sample return capsule returned to Earth bearing the first solid samples from a primitive solar system body, Comet 81P/Wild2, and a collector dedicated to the capture and return of contemporary interstellar dust. Both collectors were approximately 0.1m(exp 2) in area and were composed of aerogel tiles (85% of the collecting area) and aluminum foils. The Stardust Interstellar Dust Collector (SIDC) was exposed to the interstellar dust stream for a total exposure factor of 20 m(exp 2) day. The Stardust Interstellar Preliminary Examination (ISPE) is a three-year effort to characterize the collection using nondestructive techniques.
Sound absorption characteristics of tree bark and forest floor
G. Reethof; O. H. McDaniel; G. M. Heisler
1977-01-01
Results of basic research on absorption of sound by tree bark and forest floors are presented. Amount of sound absorption by tree bark was determined by laboratory experiments with bark samples in a standing-wave tube. A modified portable standing-wave tube was used to measure absorption of sound by forest floors with different moisture contents, with and without leaf...
Need to Identify Parameters of Concrete in the Weakest Zone of the Industrial Floor
NASA Astrophysics Data System (ADS)
Stawiski, Bohdan; Radzik, Łukasz
2017-10-01
The ways in which industrial floors are exploited leads to the requirement for the highest strength of their upper zone. Physical phenomena occurring during the compaction and hardening of the concrete cause different strength distributions. In the top zone of industrial floors, the strength is significantly lower (over a dozen MPa) than the strength in the bottom zone (several dozen MPa). Standard tests of control samples do not detect this fact. Processes for the application and finishing of embedded mineral-aggregate hardeners (dry shakes) can be regarded as uncontrolled. The effects of the use of dry shakes are not evaluated. In combination with the phenomenon of bleeding, they often fail by delamination. This paper presents the results of industrial floor testing. The ultrasonic pulse velocity method with dry point contact transducers was used. The results show how upper layer strength was reduced, and how dry shakes application affected the strength of the floor. The strength distribution in hardened concrete, which delaminated from the rest of the floor was presented as well. The extension of compulsory control tests of concrete samples was proposed. In the authors’ opinion, particular attention should be paid to 3 centimetres of the upper layer.
NASA Astrophysics Data System (ADS)
Engelbrecht, Johann P.; Stenchikov, Georgiy; Jish Prakash, P.; Lersch, Traci; Anisimov, Anatolii; Shevchenko, Illia
2017-09-01
Mineral dust is the most abundant aerosol, having a profound impact on the global energy budget. This research continues our previous studies performed on surface soils in the Arabian Peninsula, focusing on the mineralogical, physical and chemical composition of dust deposits from the atmosphere at the Arabian Red Sea coast. For this purpose, aerosols deposited from the atmosphere are collected during 2015 at six sites on the campus of the King Abdullah University of Science and Technology (KAUST) situated on the Red Sea coastal plain of Saudi Arabia and subjected to the same chemical and mineralogical analysis we conducted on soil samples. Frisbee deposition samplers with foam inserts were used to collect dust and other deposits, for the period December 2014 to December 2015. The average deposition rate measured at KAUST for this period was 14 g m-2 per month, with lowest values in winter and increased deposition rates in August to October. The particle size distributions provide assessments of < 10 and < 2.5 µm dust deposition rates, and it is suggested that these represent proxies for PM10 (coarse) and PM2. 5 (fine) particle size fractions in the dust deposits.X-ray diffraction (XRD) analysis of a subset of samples confirms variable amounts of quartz, feldspars, micas, and halite, with lesser amounts of gypsum, calcite, dolomite, hematite, and amphibole. Freeze-dried samples were re-suspended onto the Teflon® filters for elemental analysis by X-ray fluorescence (XRF), while splits from each sample were analyzed for water-soluble cations and anions by ion chromatography. The dust deposits along the Red Sea coast are considered to be a mixture of dust emissions from local soils and soils imported from distal dust sources. Airborne mineral concentrations are greatest at or close to dust sources, compared to those through medium- and long-range transport. It is not possible to identify the exact origin of deposition samples from the mineralogical and chemical results alone. These aerosol data are the first of their kind from the Red Sea region. They will help assess their potential nutrient input into the Red Sea, as well the impact on human health, industry, and solar panel efficiency. These data will also support dust modeling in this important dust belt source area by better quantifying dust mass balance and optical properties of airborne dust particles.
Forensic analysis of the microbiome of phones and shoes
Lax, Simon; Hampton-Marcell, Jarrad T.; Gibbons, Sean M.; ...
2015-05-12
Background: Microbial interaction between human-associated objects and the environments we inhabit may have forensic implications, and the extent to which microbes are shared between individuals inhabiting the same space may be relevant to human health and disease transmission. In this study, two participants sampled the front and back of their cell phones, four different locations on the soles of their shoes, and the floor beneath them every waking hour over a 2-day period. A further 89 participants took individual samples of their shoes and phones at three different scientific conferences. Results: Samples taken from different surface types maintained significantly differentmore » microbial community structures. The impact of the floor microbial community on that of the shoe environments was strong and immediate, as evidenced by Procrustes analysis of shoe replicates and significant correlation between shoe and floor samples taken at the same time point. Supervised learning was highly effective at determining which participant had taken a given shoe or phone sample, and a Bayesian method was able to determine which participant had taken each shoe sample based entirely on its similarity to the floor samples. Both shoe and phone samples taken by conference participants clustered into distinct groups based on location, though much more so when an unweighted distance metric was used, suggesting sharing of low-abundance microbial taxa between individuals inhabiting the same space. In conclusion, correlations between microbial community sources and sinks allow for inference of the interactions between humans and their environment.« less
Forensic analysis of the microbiome of phones and shoes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lax, Simon; Hampton-Marcell, Jarrad T.; Gibbons, Sean M.
Background: Microbial interaction between human-associated objects and the environments we inhabit may have forensic implications, and the extent to which microbes are shared between individuals inhabiting the same space may be relevant to human health and disease transmission. In this study, two participants sampled the front and back of their cell phones, four different locations on the soles of their shoes, and the floor beneath them every waking hour over a 2-day period. A further 89 participants took individual samples of their shoes and phones at three different scientific conferences. Results: Samples taken from different surface types maintained significantly differentmore » microbial community structures. The impact of the floor microbial community on that of the shoe environments was strong and immediate, as evidenced by Procrustes analysis of shoe replicates and significant correlation between shoe and floor samples taken at the same time point. Supervised learning was highly effective at determining which participant had taken a given shoe or phone sample, and a Bayesian method was able to determine which participant had taken each shoe sample based entirely on its similarity to the floor samples. Both shoe and phone samples taken by conference participants clustered into distinct groups based on location, though much more so when an unweighted distance metric was used, suggesting sharing of low-abundance microbial taxa between individuals inhabiting the same space. In conclusion, correlations between microbial community sources and sinks allow for inference of the interactions between humans and their environment.« less
Building G interior, second floor oblique looking southwest, showing storage ...
Building G interior, second floor oblique looking southwest, showing storage area for samples - Daniel F. Waters Germantown Dye Works, Building G, 37-55 East Wister Street, Philadelphia, Philadelphia County, PA
Reduction of airborne radioactive dust by means of a charged water spray.
Bigu, J; Grenier, M G
1989-07-01
An electrostatic precipitator based on charged water spray technology has been used in an underground uranium mine to control long-lived radioactive dust and short-lived aerosol concentration in a mine gallery where dust from a rock breaking/ore transportation operation was discharged. Two main sampling stations were established: one upstream of the dust precipitator and one downstream. In addition, dust samplers were placed at different locations between the dust discharge and the end of the mine gallery. Long-lived radioactive dust was measured using cascade impactors and nylon cyclone dust samplers, and measurement of the radioactivity on the samples was carried out by conventional methods. Radon and thoron progeny were estimated using standard techniques. Experiments were conducted under a variety of airflow conditions. A maximum radioactive dust reduction of about 40% (approximately 20% caused by gravitational settling) at a ventilation rate of 0.61 m3/sec was obtained as a result of the combined action of water scrubbing and electrostatic precipitation by the charged water spray electrostatic precipitator. This represents the optimum efficiency attained within the range of ventilation rates investigated. The dust reduction efficiency of the charged water spray decreased with increasing ventilation rate, i.e., decreasing air residence time, and hence, reduced dust cloud/charged water droplets mixing time.
Fan, Xinghua; Kubwabo, Cariton; Rasmussen, Pat E; Wu, Fang
2016-04-01
An analytical method was developed for the measurement of 18 novel halogenated flame retardants in house dust. Sample preparation was based on ultrasound-assisted solvent extraction and clean up with solid phase extraction (SPE). Sample extracts were analyzed by gas chromatography-mass spectrometry (GC/MS) operated in electron capture negative ion (ECNI) chemical ionization mode. Baseline data from 351 fresh (active) dust samples collected under the Canadian House Dust Study (CHDS) revealed that five out of 18 target chemicals were present with detection frequencies higher than 90 %. Median (range) concentrations for these five compounds were as follows: 104 (<1.5-13,000) ng/g for 2-ethylhexyl-2,3,4,5-tetrabromobenzoate (EHTBB), 8.5 (<1.7-2390) ng/g for 1,2-bis(2,4,6-tribromophenoxy)ethane (BTBPE), 10.2 (<1.7-430) ng/g for hexabromobenzene (HBB), 2.9 (<1.2-1410) ng/g for syn-dechlorane plus (syn-DP) and 5.6 (<1.9-1570) ng/g for anti-dechlorane plus (anti-DP). A comparison of two sampling methods in a subset of 40 homes showed significant positive correlations between samples of "active" dust and samples taken directly from the household vacuum cleaner for all target compounds having median values above their corresponding method detection limits (MDLs). In addition, the method was also applied to the analysis of the targeted compounds in National Institute of Standards and Technology (NIST) standard reference material (SRM 2585, organic contaminants in house dust). Results from the current study could contribute to the potential certification of target chemicals in SRM 2585.
NASA Astrophysics Data System (ADS)
Webb, N.; Chappell, A.; Van Zee, J.; Toledo, D.; Duniway, M.; Billings, B.; Tedela, N.
2017-12-01
Anthropogenic land use and land cover change (LULCC) influence global rates of wind erosion and dust emission, yet our understanding of the magnitude of the responses remains poor. Field measurements and monitoring provide essential data to resolve aeolian sediment transport patterns and assess the impacts of human land use and management intensity. Data collected in the field are also required for dust model calibration and testing, as models have become the primary tool for assessing LULCC-dust cycle interactions. However, there is considerable uncertainty in estimates of dust emission due to the spatial variability of sediment transport. Field sampling designs are currently rudimentary and considerable opportunities are available to reduce the uncertainty. Establishing the minimum detectable change is critical for measuring spatial and temporal patterns of sediment transport, detecting potential impacts of LULCC and land management, and for quantifying the uncertainty of dust model estimates. Here, we evaluate the effectiveness of common sampling designs (e.g., simple random sampling, systematic sampling) used to measure and monitor aeolian sediment transport rates. Using data from the US National Wind Erosion Research Network across diverse rangeland and cropland cover types, we demonstrate how only large changes in sediment mass flux (of the order 200% to 800%) can be detected when small sample sizes are used, crude sampling designs are implemented, or when the spatial variation is large. We then show how statistical rigour and the straightforward application of a sampling design can reduce the uncertainty and detect change in sediment transport over time and between land use and land cover types.
Non-targeted screening of house dust samples using accurate mass TOFMS
House dust exists as an environmental repository of chemicals to which we are exposed in our homes. A growing number of studies have targeted select persistent organic and inorganic pollutants found in house dust. Many have concluded that dust exists as an important human expos...
Indoor air quality and health problems associated with damp floor coverings.
Tuomainen, Anneli; Seuri, Markku; Sieppi, Anne
2004-04-01
To study the relationship between a high incidence of bronchial asthma among employees working in an office building and an indoor air problem related to the degradation of polyvinyl chloride (PVC) floor coverings in the building. The indoor air measurements and results of renovations are also described. Employees' symptoms were surveyed by a questionnaire, and the incidence of asthma was calculated from the medical records for 1997-2000. The quality of indoor air was assessed by microbial sampling and by investigation of the building for possible moisture damage. Indoor air was sampled for volatile organic compounds (VOCs) through Tenax adsorbent tubes. In situ volatile emission measurements from the concrete floor were performed via the field and laboratory emission cell (FLEC) method. In an office with approximately 150 employees, eight new cases of asthma were found in 4 years. In addition, the workers complained of respiratory, conjunctival and nasal symptoms. Emissions indicating the degradation of plastic floor coverings (e.g. 2-ethyl-1-hexanol, 1-butanol) were found in the indoor air and floor material samples. The plastic floor coverings, adhesives and the levelling layers were carefully removed from 12 rooms. The VOCs had diffused into the underlying concrete slabs. The concrete was warmed to remove the diffused VOCs from these areas. After the repairs the concentrations of the VOCs indicating the degradation of PVC, decreased, as did the prevalence of the employees' symptoms and several asthma patients' need for medication. The workers in the office building complained of several respiratory, conjunctival and dermal symptoms. The incidence of adult-onset asthma was approximately nine-times higher than that among Finns employed in similar work. The most probable single cause of the indoor air problem was the degradation of the plastic floor coverings.
DOE Office of Scientific and Technical Information (OSTI.GOV)
S Walker; H Jamieson; P Rasmussen
2011-12-31
Determination of the source and form of metals in house dust is important to those working to understand human and particularly childhood exposure to metals in residential environments. We report the development of a synchrotron microprobe technique for characterization of multiple metal hosts in house dust. We have applied X-ray fluorescence for chemical characterization and X-ray diffraction for crystal structure identification using microfocused synchrotron X-rays at a less than 10 {micro}m spot size. The technique has been evaluated by application to archived house dust samples containing elevated concentrations of Pb, Zn, and Ba in bedroom dust, and Pb and Asmore » in living room dust. The technique was also applied to a sample of soil from the corresponding garden to identify linkages between indoor and outdoor sources of metals. Paint pigments including white lead (hydrocerussite) and lithopone (wurtzite and barite) are the primary source of Pb, Zn, and Ba in bedroom dust, probably related to renovation activity in the home at the time of sampling. The much lower Pb content in the living room dust shows a relationship to the exterior soil and no specific evidence of Pb and Zn from the bedroom paint pigments. The technique was also successful at confirming the presence of chromated copper arsenate treated wood as a source of As in the living room dust. The results of the study have confirmed the utility of this approach in identifying specific metal forms within the dust.« less
Environmental Sequencing of Biotic Components of Dust in the Chihuahuan Desert
NASA Astrophysics Data System (ADS)
Walsh, E.; Gill, T. E.; Rivas, J. A., Jr.; Leung, M. Y.; Mohl, J.
2015-12-01
A growing number of studies mark the role of wind in dispersing biota. Most of these approaches have used traditional methods to assess taxonomic diversity. Here we used next generation sequencing to characterize microbiota in dust collected from the Chihuahuan Desert. Atmospheric dust was collected during events during 2011-2014 using dry deposition collectors placed at two sites in El Paso Co., TX. In parallel experiments, we rehydrated subsamples of dust and conducted PCR amplifications using conserved primers for 16S and 18S ribosomal genes. Sequenced reads were de-multiplexed, quality filtered, and processed using QIIME. Taxonomy was assigned based on pairwise identity using BLAST for microbial eukaryotes. All samples were rarefied to a set number of sequences per sample prior to downstream analyses. Bioinformatic analysis of four of the dust samples yielded a diversity of biota, including zooplankton, bacteria, fungi, algae, and protists, but fungi predominate (>90% of both 10K and 3K reads). In our rehydrations of dust samples from the U.S. southwest nematodes, gastrotrichs, tardigrades, monogonont and bdelloid rotifers, branchiopods and numerous ciliates have been recovered. Variability in genetic diversity among samples is based, in part, on the source and extent of the particular dust event. We anticipate the same patterns will be seen in the complete data set. These preliminary results indicate that wind is a major transporter of not only fungi, bacteria and other unicellular organisms but may also be important in shaping the distribution patterns of multi-cellular organisms such as those that inhabit aquatic environments in the arid southwestern US.
Fu, Xi; Lindgren, Torsten; Guo, Moran; Cai, Gui-Hong; Lundgren, Håkan; Norbäck, Dan
2013-06-01
There has been concern about the cabin environment in commercial aircraft. We measured cat, dog and horse allergens and fungal DNA in cabin dust and microbial volatile organic compounds (MVOCs) in cabin air. Samples were collected from two European airline companies, one with cabins having textile seats (TSC) and the other with cabins having leather seats (LSC), 9 airplanes from each company. Dust was vacuumed from seats and floors in the flight deck and different parts of the cabin. Cat (Fel d1), dog (Can f1) and horse allergens (Equ cx) were analyzed by ELISA. Five sequences of fungal DNA were analyzed by quantitative PCR. MVOCs were sampled on charcoal tubes in 42 TSC flights, and 17 compounds were analyzed by gas chromatography mass spectrometry (GC-MS) with selective ion monitoring (SIM). MVOC levels were compared with levels in homes from Nordic countries. The weight of dust was 1.8 times larger in TSC cabins as compared to LSC cabins (p < 0.001). In cabins with textile seats, the geometric mean (GM) concentrations of Fel d1, Can f1 and Equ cx were 5359 ng g(-1), 6067 ng g(-1), and 13 703 ng g(-1) (GM) respectively. Levels of Fel d1, Can f1 and Equ cx were 50 times, 27 times and 75 times higher respectively, in TSC cabins as compared to LSC cabins (p < 0.001). GM levels of Aspergillus/Penicillium DNA, Aspergillus versicolor DNA, Stachybotrys chartarum DNA and Streptomyces DNA were all higher in TSC as compared to LSC (p < 0.05). The sum of MVOCs in cabin air (excluding butanols) was 3192 ng m(-3) (GM), 3.7 times higher than in homes (p < 0.001) and 2-methyl-1-butanol and 3-methyl-1-butanol concentrations were 15-17 times higher as compared to homes (p < 0.001). Concentrations of isobutanol, 1-butanol, dimethyldisulfide, 2-hexanone, 2-heptanone, 3-octanone, isobutyl acetate and ethyl-2-methylbutyrate were lower in cabin air as compared to homes (p < 0.05). In conclusion, textile seats are much more contaminated by pet allergens and fungal DNA than leather seats. The use of seats with smooth surfaces should be encouraged. The MVOC levels differed between cabin air and homes.
30 CFR 71.209 - Respirable dust samples; transmission by operator.
Code of Federal Regulations, 2012 CFR
2012-07-01
... operator. 71.209 Section 71.209 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Sampling Procedures § 71.209 Respirable dust samples; transmission by...
30 CFR 71.209 - Respirable dust samples; transmission by operator.
Code of Federal Regulations, 2013 CFR
2013-07-01
... operator. 71.209 Section 71.209 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Sampling Procedures § 71.209 Respirable dust samples; transmission by...
30 CFR 71.209 - Respirable dust samples; transmission by operator.
Code of Federal Regulations, 2014 CFR
2014-07-01
... operator. 71.209 Section 71.209 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Sampling Procedures § 71.209 Respirable dust samples; transmission by...
Characterisation of bio-aerosols during dust storm period in N-NW India
NASA Astrophysics Data System (ADS)
Yadav, Sudesh; Chauhan, M. S.; Sharma, Anupam
Bio-investigations for pollen and spores were performed on dry free-fall dust and PM 10 aerosol samples, collected from three different locations separated by a distance of 600 km, situated in dust storm hit region of N-NW India. Presence of pollen of trees namely Prosopis ( Prosopis juliflora and Prosopis cinearia), Acacia, Syzygium, Pinus, Cedrus, Holoptelea and shrubs namely Ziziphus, Ricinus, Ephedra and members of Fabaceae, Oleaceae families was recorded but with varying proportions in the samples of different locations. Poaceae, Chenopodiaceae/Amaranthaceae, Caryophyllaceae, Brassicaceae and Cyperaceae (sedges) were some of the herb pollen identified in the samples. Among the fungal spores Nigrospora was seen in almost all samples. Nigrospora is a well known allergen and causes health problems. The concentration of trees and shrubs increases in the windward direction just as the climate changes from hot arid to semiarid. The higher frequency of grasses (Poaceae) or herbs could either be a result of the presence of these herbs in the sampling area and hence the higher production of pollen/spores or due to the resuspension from the exposed surface by the high-intensity winds. But we cannot ascertain the exact process at this stage. The overall similarity in the pollen and spore assemblage in our dust samples indicates a common connection or source(s) to the dust in this region. Presence of the pollen of the species of Himalayan origin in our entire samples strongly point towards a Himalayan connection, could be direct or indirect, to the bioaerosols and hence dust in N-NW India. In order to understand the transport path and processes involved therein, present study needs further extension with more number of samples and with reference to meteorological parameters.
Gill, Christina; McEwan, Neil; McGarry, John; Nuttall, Tim
2011-04-01
Dry pet food is a potential source of exposure to house dust and storage mite allergens in canine atopic dermatitis. This study evaluated contamination of house dust and dry dog food stored in paper bags, sealable plastic bags and sealable plastic boxes in 10 households for 90 days using Acarex(®) tests for guanine, a Der p 1 ELISA and mite flotation. Acarex(®) tests were negative in all the food samples but positive in all the house dust samples. The Der p 1 levels and mite numbers significantly increased in food from paper bags (P = 0.0073 and P = 0.02, respectively), but not plastic bags or boxes. Mite numbers and Der p 1 levels were 10-1000 times higher in house dust than the corresponding food samples (P < 0.0001). There were significant correlations between Der p 1 in house dust and food from the paper (P < 0.0001) and plastic bags (P = 0.003), and mite numbers in house dust and food from the paper bags (P = 0.0007). Bedding and carpets were significantly associated with Der p 1 levels in house dust (P = 0.015 and P = 0.01, respectively), and food from the paper (both P = 0.02) and plastic bags (P = 0.03 and P = 0.04, respectively). Mites were identified in six of 10 paper bag, three of 10 plastic bag, one of 10 plastic box and nine of 10 house dust samples. These comprised Dermatophagoides (54%), Tyrophagus (10%; all from food) and unidentified mites (36%). Storage of food in sealable plastic boxes largely prevented contamination for 3 months. Exposure to mites and mite proteins in all the stored food, however, appeared to be trivial compared with house dust. © 2010 The Authors. Journal compilation © 2010 ESVD and ACVD.
SPARCLE: Space Plasma Alleviation of Regolith Concentrations in the Lunar Environment
NASA Astrophysics Data System (ADS)
Clark, P. E.; Keller, J. W.; Curtis, S. A.; Nuth, J. A.; Stubbs, T. J.; Farrell, W. M.
2006-05-01
The return of robotic devices and humans to the Moon will occur in the near future. Based on our previous experience, surface dust is a major problem requiring a solution: During Apollo landings, extensive locally- induced stirring of the regolith caused dust to be suspended long enough to come into contact with conducting surfaces. Dust behaved like abrasive Velcro: it adhered to everything and attempts to remove it by simply brushing did not remove fines (<10) and resulted in severe abrasion. Lunar fines, because of their electrostatic charging, were relatively difficult to collect in sample bags along with other size range particles. Within hours, seals were broken, samples contaminated, and portions of the samples, especially fines, lost. Because of this difficulty, details on lunar dust are relatively sparse. Obviously, the strategies initially implemented to deal with lunar dust failed. A major technological challenge will be developing a dust mitigation strategy. A currently proposed strategy based increased magnetic susceptibility in lunar fines may not work uniformly well for fines of non-mare, or non-lunar, composition. Based on dust behavior already observed on previous missions, we believe the successful strategy will deal with dust dynamics resulting from interaction between mechanical and electrostatic forces. We are planning test and develop an electrostatically-based device to modulate the electrical potential of conducting surfaces, hence to self clean exposed surfaces while collecting dust samples. It would scan a surface constantly to control its potential, and a plate of the opposite potential. As a first step, an experimental low mass, power, and volume device with complimentary electron and ion guns with specially designed self-cleaning nozzles are being designed for to test our concept and develop a working charging and discharging strategy in the lunar environment. Meanwhile, a laboratory simulation will act as a feasibility study for a laboratory breadboard self-cleaning device based on the use of combined electron or ion beams. The compact device would act as plasma dust sweeper.
Lab Analysis of Dust Wipe Samples
Dust wipe samples collected on residential properties near the fenceline of KCBX North and South Terminals in Chicago, which store and handle pet coke, were analyzed for polycyclic aromatic hydrocarbons (PAHs) and trace metals and minerals.
Exposures to quartz, diesel, dust, and welding fumes during heavy and highway construction.
Woskie, Susan R; Kalil, Andrew; Bello, Dhimiter; Virji, M Abbas
2002-01-01
Personal samples for exposure to dust, diesel exhaust, quartz, and welding fume were collected on heavy and highway construction workers. The respirable, thoracic, and inhalable fractions of dust and quartz exposures were estimated from 260 personal impactor samples. Respirable quartz exposures exceeded the National Institute for Occupational Safety and Health (NIOSH) recommended exposure limit (REL) in 7-31% of cases for the trades sampled. More than 50% of the samples in the installation of drop ceilings and wall tiles and concrete finish operations exceeded the NIOSH REL for quartz. Thoracic exposures to quartz and dust exceeded respirable exposures by a factor of 4.5 and 2.8, respectively. Inhalable exposures to quartz and dust exceeded respirable exposures by a factor of 25.6 and 9.3, respectively. These findings are important due to the identification of quartz as a carcinogen by the National Toxicology Program and the International Agency for Research on Cancer. Fourteen percent of the personal samples for EC (n = 261), collected as a marker for diesel exhaust, exceeded the American Conference of Governmental Industrial Hygienists (ACGIH) threshold limit value (TLV) for diesel exhaust. Seventeen of the 22 (77%) samples taken during a partially enclosed welding operation reached or exceeded the ACGIH TLV of 5 mg/m3 for welding fume.
NASA Astrophysics Data System (ADS)
Wu, Feng; Zhang, Daizhou; Cao, Junji; Guo, Xiao; Xia, Yao; Zhang, Ting; Lu, Hui; Cheng, Yan
2017-12-01
Sulfate and nitrate compounds can greatly increase the hygroscopicity of mineral particles in the atmosphere and consequently alter the particles' physical and chemical properties. Their uptake on long-distance-transported Asian dust particles within mainland China has been reported to be substantial in previous studies, but the production was very inefficient in other studies. We compared these two salts in particles collected from a synoptic-scale, mid-latitude, cyclone-induced dust storm plume at the Tengger Desert (38.79° N, 105.38° E) and in particles collected in a postfrontal dust plume at an urban site in Xi'an (34.22° N, 108.87° E) when a front-associated dust storm from the Tengger Desert arrived there approximately 700 km downwind. The results showed that the sulfate concentration was not considerably different at the two sites, while the nitrate concentration was slightly larger at the urban site than that at the desert site. The estimated nitrate production rate was 4-5 ng µg-1 of mineral dust per day, which was much less than that in polluted urban air. The adiabatic process of the dust-loading air was suggested to be the reason for the absence of sulfate formation, and the uptake of background HNO3 was suggested to be the reason for the small nitrate production. According to our investigation of the published literature, the significant sulfate and nitrate in dust-storm-associated samples within the continental atmosphere reported in previous studies cannot be confirmed as actually produced on desert dust particles; the contribution from locally emitted and urban mineral particles or from soil-derived sulfate was likely substantial because the weather conditions in those studies indicated that the collection of the samples was started before dust arrival, or the air from which the samples were collected was a mixture of desert dust and locally emitted mineral particles. These results suggest that the production of nitrate and sulfate on dust particles following cold fronts is likely limited when the particles move from the desert to populated areas within the continent. For an accurate quantification of sulfate and nitrate formed on long-distance-transported desert dust particles at downwind populated areas in eastern China, dust collection efforts are indispensable to minimize any possible influence by locally emitted particles or at least to ensure that the samples are collected after dust arrival.
Atmospheric and surface properties of Mars obtained by infrared spectroscopy on Mariner 9
NASA Technical Reports Server (NTRS)
Conrath, B.; Curran, R. J.; Hanel, R.; Kunde, V. G.; Marguire, W.; Pearl, J.; Pirraglia, J. A.; Welker, J.; Burke, T.
1972-01-01
During the eleven month operational lifetime of Mariner 9, the infrared spectroscopy experiment obtained data over a large portion of Mars. Recently obtained spectra indicate that strong seasonal variations in the water vapor distribution over both polar regions occurred. The wettest atmospheric conditions observed so far contain 20 to 30 precipitable microns of water over the north polar cap during northern spring. A low resolution pressure map is presented which covers that portion of the planet between latitudes -60 deg and +25 deg. A more detailed study of the Coprates canyon indicates that at its lowest point the canyon floor must be at least 5 km below the rim. Applications of tidal theory to temperature fields derived from the spectra indicate diurnal surface pressure fluctuations of as much as 12 percent during the great dust storm of 1971-72. Qualitative arguments based on radiative transfer calculations for model dust clouds composed of spherical quartz particles suggest that particle radii during the storm were of the order of a few microns.
Particle atlas of World Trade Center dust
Lowers, Heather; Meeker, Gregory P.
2005-01-01
The United States Environmental Protection Agency (EPA) has begun a reassessment of the presence of World Trade Center (WTC) dust in residences, public buildings, and office spaces in New York City, New York. Background dust samples collected from residences, public buildings, and office spaces will be analyzed by multiple laboratories for the presence of WTC dust. Other laboratories are currently studying WTC dust for other purposes, such as health effects studies. To assist in inter-laboratory consistency for identification of WTC dust components, this particle atlas of phases in WTC dust has been compiled.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Amblard, A.; Riguccini, L.; Temi, P.
We compute the properties of a sample of 221 local, early-type galaxies with a spectral energy distribution (SED) modeling software, CIGALEMC. Concentrating on the star-forming (SF) activity and dust contents, we derive parameters such as the specific star formation rate (sSFR), the dust luminosity, dust mass, and temperature. In our sample, 52% is composed of elliptical (E) galaxies and 48% of lenticular (S0) galaxies. We find a larger proportion of S0 galaxies among galaxies with a large sSFR and large specific dust emission. The stronger activity of S0 galaxies is confirmed by larger dust masses. We investigate the relative proportionmore » of active galactic nuclei (AGNs) and SF galaxies in our sample using spectroscopic Sloan Digital Sky Survey data and near-infrared selection techniques, and find a larger proportion of AGN-dominated galaxies in the S0 sample than the E one. This could corroborate a scenario where blue galaxies evolve into red ellipticals by passing through an S0 AGN active period while quenching its star formation. Finally, we find a good agreement comparing our estimates with color indicators.« less
Microbes and Microstructure: Dust's Role in the Snowpack Evolution
NASA Astrophysics Data System (ADS)
Lieblappen, R.; Courville, Z.; Fegyveresi, J. M.; Barbato, R.; Thurston, A.
2017-12-01
Dust is a primary vehicle for transporting microbial communities to polar and alpine snowpacks both through wind distribution (dry deposition) and snowfall events (wet deposition). The resulting microbial community diversity in the snowpack may then resemble the source material properties rather than its new habitat. Dust also has a strong influence on the microstructural properties of snow, resulting in changes to radiative and mechanical properties. As local reductions in snowpack albedo lead to enhanced melting and a heterogeneous snow surface, the microbial communities are also impacted. Here we study the impact of the changing microstructure in the snowpack, its influence on microbial function, and the fate of dust particles within the snow matrix. We seek to quantify the changes in respiration and water availability with the onset of melt. Polar samples were collected from the McMurdo Ice Shelf, Antarctica in February, 2017, while alpine samples were collected from Silverton, CO from October to May, 2017 as part of the Colorado Dust on Snow (CDOS) network. At each site, coincident meteorological data provides temperature, wind, and radiative measurements. Samples were collected immediately following dust deposition events and after subsequent snowpack evolution. We used x-ray micro-computed tomography to quantify the microstructural evolution of the snow, while also imaging the microstructural distribution of the dust within the snow. The dust was then collected and analyzed for chemical and microbial activity.
Dust fallout in Kuwait city: deposition and characterization.
Al-Awadhi, Jasem M; Alshuaibi, Arafat A
2013-09-01
Dust fallouts in Kuwait city was monitored on monthly basis during the period from March 2011 to February 2012 at 10 locations. The results of this study reveal that: (1) monthly dust deposition rates ranged from 0.002 to 0.32 kg/m(2) with average deposition rate of 0.053 kg/m(2) and annual average deposition rate of 0.59 kg/m(2), ranking the first out of 56 dust deposition rates observed throughout the world; (2) on average, about 55.9% of the settled dust have fine to very fine sand fraction sizes, while silt and clay comprise an average of 37.4 and 1.4% of the total sample, respectively; (3) the concentrations for Zn and Mo out of 15 other elements analyzed from the dust were up to 11 times higher than their soil background values in Kuwait, while Pb and Ni were about seven times higher; (4) Mo, Ni, Pb and Zn show maximum enrichment relative to the upper continental crustal component (Mn); (5) Sr, Zr and Zn show highest concretions among all collected samples; and (6) quartz and calcite were the dominant minerals in the dust samples. The distribution of the heavy metals in dust seems to be controlled mainly by the land uses and the volume of traffic emissions. Copyright © 2013 Elsevier B.V. All rights reserved.
The distribution of mercury in a forest floor transect across the central United States
Charles H. (Hobie) Perry; Michael C. Amacher; William Cannon; Randall K. Kolka; Laurel Woodruff
2009-01-01
Mercury (Hg) stored in soil organic matter may be released when the forest floor is consumed by fire. Our objective is to document the spatial distribution of forest floor Hg for a transect crossing the central United States. Samples collected by the Forest Service, U.S. Department of Agriculture's Forest Inventory and Analysis Soil Quality Indicator were tested...
Cometary Dust: The Diversity of Primitive Matter
NASA Technical Reports Server (NTRS)
Wooden, D. H.; Ishiiii, H. A.; Zolensky, M. E.
2017-01-01
The connections between comet dust and primitive chondrites from asteroids has strengthened considerably over the past decade. Understanding the importance of the connections between Stardust samples and chondrites requires geochemistry lingo as well as a perspective of other cometary dust samples besides Stardust. We present the principal findings of an extensive review prepared for by us for the June 2016 "Cometary Science After Rosetta" meeting at The Royal Society, London.
Phi, Thai Ha; Chinh, Pham Minh; Cuong, Doan Danh; Ly, Luong Thi Mai; Van Thinh, Nguyen; Thai, Phong K
2018-01-01
There is a need to assess the risk of exposure to metals via roadside dust in Vietnam where many people live along the road/highways and are constantly exposed to roadside dust. In this study, we collected dust samples at 55 locations along two major Highways in north-east Vietnam, which passed through different land use areas. Samples were sieved into three different particle sizes and analyzed for concentrations of eight metals using a X-ray fluorescence instrument. The concentrations and environmental indices (EF, I geo ) of metals were used to evaluate the degree of pollution in the samples. Among different land uses, industrial areas could be highly polluted with heavy metals in roadside dust, followed by commerce and power plants. Additionally, the traffic density probably played an important role; higher concentrations were observed in samples from Highway No. 5 where traffic is several times higher than Highway No. 18. According to the risk assessment, Cr poses the highest noncarcinogenic risk even though the health hazard index values of assessed heavy metals in this study were within the acceptable range. Our assessment also found that the risk of exposure to heavy metals through roadside dust is much higher for children than for adults.
Alpha Air Sample Counting Efficiency Versus Dust Loading: Evaluation of a Large Data Set
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hogue, M. G.; Gause-Lott, S. M.; Owensby, B. N.
Dust loading on air sample filters is known to cause a loss of efficiency for direct counting of alpha activity on the filters, but the amount of dust loading and the correction factor needed to account for attenuated alpha particles is difficult to assess. In this paper, correction factors are developed by statistical analysis of a large database of air sample results for a uranium and plutonium processing facility at the Savannah River Site. As is typically the case, dust-loading data is not directly available, but sample volume is found to be a reasonable proxy measure; the amount of dustmore » loading is inferred by a combination of the derived correction factors and a Monte Carlo model. The technique compares the distribution of activity ratios [beta/(beta + alpha)] by volume and applies a range of correction factors on the raw alpha count rate. The best-fit results with this method are compared with MCNP modeling of activity uniformly deposited in the dust and analytical laboratory results of digested filters. Finally, a linear fit is proposed to evenly-deposited alpha activity collected on filters with dust loading over a range of about 2 mg cm -2 to 1,000 mg cm -2.« less
Alpha Air Sample Counting Efficiency Versus Dust Loading: Evaluation of a Large Data Set
Hogue, M. G.; Gause-Lott, S. M.; Owensby, B. N.; ...
2018-03-03
Dust loading on air sample filters is known to cause a loss of efficiency for direct counting of alpha activity on the filters, but the amount of dust loading and the correction factor needed to account for attenuated alpha particles is difficult to assess. In this paper, correction factors are developed by statistical analysis of a large database of air sample results for a uranium and plutonium processing facility at the Savannah River Site. As is typically the case, dust-loading data is not directly available, but sample volume is found to be a reasonable proxy measure; the amount of dustmore » loading is inferred by a combination of the derived correction factors and a Monte Carlo model. The technique compares the distribution of activity ratios [beta/(beta + alpha)] by volume and applies a range of correction factors on the raw alpha count rate. The best-fit results with this method are compared with MCNP modeling of activity uniformly deposited in the dust and analytical laboratory results of digested filters. Finally, a linear fit is proposed to evenly-deposited alpha activity collected on filters with dust loading over a range of about 2 mg cm -2 to 1,000 mg cm -2.« less
Sorption of Organophosphorus Flame-Retardants on Settled ...
Dust is an important sink for indoor air pollutants, such as organophosphorus flame-retardants (OPFRs) that are used as additives in industrial and consumer products including electrical and electronic products, furniture, plastics, textile, and building/construction materials. This research investigated the sorption of OPFRs, tris(2-chloroethyl) phosphate (TCEP), tris(1-chlor-2-propyl) phosphate (TCPP), and tris(1,3-dichloro-2-propyl) phosphate (TDCPP) on settled Arizona Test Dust (ATD) using a dual small chamber system. During the test, seven free film release paper dust trays covered with ATD were placed in the sink test chamber. Constant gas phase OPFRs from the source chamber were dosed into the test chamber. The dust evenly spread on each dust tray was removed from the test chamber at different exposure times to determine the amount of OPFRs absorbed by the dust. The ATD has been characterized for a nominal particle size and surface area. The mass of dust on each of seven dust trays was weighed before the dust was placed inside the sink chamber. OPFRs concentrations at the inlet and faceplate of the test chamber were monitored by collecting polyurethane foam (PUF) samples. The OPFR exposed dust and PUF samples were extracted by 1:1 ethyl acetate/methylene chloride and analyzed on GC/MS. The data were used to calculate the OPFR sorption concentration on the dust through dust/air partition. Settled dust can adsorb OPFR from air. The sorption concentration wa
Mora, Maximilian; Perras, Alexandra; Alekhova, Tatiana A; Wink, Lisa; Krause, Robert; Aleksandrova, Alina; Novozhilova, Tatiana; Moissl-Eichinger, Christine
2016-12-20
The International Space Station (ISS) represents a unique biotope for the human crew but also for introduced microorganisms. Microbes experience selective pressures such as microgravity, desiccation, poor nutrient-availability due to cleaning, and an increased radiation level. We hypothesized that the microbial community inside the ISS is modified by adapting to these stresses. For this reason, we analyzed 8-12 years old dust samples from Russian ISS modules with major focus on the long-time surviving portion of the microbial community. We consequently assessed the cultivable microbiota of these samples in order to analyze their extremotolerant potential against desiccation, heat-shock, and clinically relevant antibiotics. In addition, we studied the bacterial and archaeal communities from the stored Russian dust samples via molecular methods (next-generation sequencing, NGS) and compared our new data with previously derived information from the US American ISS dust microbiome. We cultivated and identified in total 85 bacterial, non-pathogenic isolates (17 different species) and 1 fungal isolate from the 8-12 year old dust samples collected in the Russian segment of the ISS. Most of these isolates exhibited robust resistance against heat-shock and clinically relevant antibiotics. Microbial 16S rRNA gene and archaeal 16S rRNA gene targeting Next Generation Sequencing showed signatures of human-associated microorganisms (Corynebacterium, Staphylococcus, Coprococcus etc.), but also specifically adapted extremotolerant microorganisms. Besides bacteria, the detection of archaeal signatures in higher abundance was striking. Our findings reveal (i) the occurrence of living, hardy microorganisms in archived Russian ISS dust samples, (ii) a profound resistance capacity of ISS microorganisms against environmental stresses, and (iii) the presence of archaeal signatures on board. In addition, we found indications that the microbial community in the Russian segment dust samples was different to recently reported US American ISS microbiota.
Are building-level characteristics associated with indoor allergens in the household?
Rosenfeld, Lindsay; Chew, Ginger L; Rudd, Rima; Emmons, Karen; Acosta, Luis; Perzanowski, Matt; Acevedo-García, Dolores
2011-02-01
Building-level characteristics are structural factors largely beyond the control of those who live in them. We explored whether building-level characteristics and indoor allergens in the household are related. We examined the relationship between building-level characteristics and indoor allergens: dust mite, cat, cockroach, and mouse. Building-level characteristics measured were presence of pests (seeing cockroaches and rodents), building type (public housing, buildings zoned commercially and residentially, and building size), and building condition (building age and violations). Allergen cutpoints were used for categorical analyses and defined as follows: dust mite: >0.25 μg/g; cat: >1 μg/g; cockroach: >1 U/g; mouse: >1.6 μg/g. In fully adjusted linear analyses, neither dust mite nor cat allergen were statistically significantly associated with any building-level characteristics. Cockroach allergen was associated with the presence of cockroaches (2.07; 95% CI, 1.23, 3.49) and living in public housing (2.14; 95% CI, 1.07, 4.31). Mouse allergen was associated with the presence of rodents (1.70; 95% CI, 1.29, 2.23), and building size: living in a low-rise (<8 floors; 0.60; 95% CI, 0.42, 0.87) or high-rise (8 + floors; 0.50; 95% CI, 0.29, 0.88; compared with house/duplex). In fully adjusted logistic analyses, cat allergen was statistically significantly associated with living in a high-rise (6.29; 95% CI, 1.51, 26.21; compared with a house/duplex). Mouse allergen was associated with living in public housing (6.20; 95% CI, 1.01, 37.95) and building size: living in a low-rise (0.16; 95% CI, 0.05, 0.52) or high-rise (0.06; 95% CI, 0.01, 0.50; compared with a house/duplex). Issues concerning building size and public housing may be particularly critical factors in reducing asthma morbidity. We suggest that future research explore the possible improvement of these factors through changes to building code and violations adherence, design standards, and incentives for landlords.
Four Interstellar Dust Candidates from the Stardust Interstellar Dust Collector
NASA Technical Reports Server (NTRS)
Westphal, A. J.; Allen, C.; Bajt, S.; Bechtel, H. A.; Borg, J.; Brenker, F.; Bridges, J.; Brownlee, D. E.; Burchell, M.; Burghammer, M.;
2011-01-01
In January 2006, the Stardust sample return capsule returned to Earth bearing the first solid samples from a primitive solar system body, Comet 81P/Wild2, and a collector dedicated to the capture and return of contemporary interstellar dust. Both collectors were approx. 0.1 sq m in area and were composed of aerogel tiles (85% of the collecting area) and aluminum foils. The Stardust Interstellar Dust Collector (SIDC) was exposed to the interstellar dust stream for a total exposure factor of 20 sq m/day. The Stardust Interstellar Preliminary Examination (ISPE) is a consortium-based project to characterize the collection using nondestructive techniques. The goals and restrictions of the ISPE are described . A summary of analytical techniques is described.
30 CFR 74.5 - Tests of coal mine dust personal sampler units.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Tests of coal mine dust personal sampler units. 74.5 Section 74.5 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH COAL MINE DUST SAMPLING DEVICES Approval Requirements for Coal Mine Dust...
30 CFR 74.5 - Tests of coal mine dust personal sampler units.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Tests of coal mine dust personal sampler units. 74.5 Section 74.5 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH COAL MINE DUST SAMPLING DEVICES Approval Requirements for Coal Mine Dust...
30 CFR 74.5 - Tests of coal mine dust personal sampler units.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Tests of coal mine dust personal sampler units. 74.5 Section 74.5 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH COAL MINE DUST SAMPLING DEVICES Approval Requirements for Coal Mine Dust...
30 CFR 74.5 - Tests of coal mine dust personal sampler units.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Tests of coal mine dust personal sampler units. 74.5 Section 74.5 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH COAL MINE DUST SAMPLING DEVICES Approval Requirements for Coal Mine Dust...
Reynolds, R.L.; Reheis, M.; Yount, J.; Lamothe, P.
2006-01-01
The recognition and characterization of aeolian dust in soil contribute to a better understanding of landscape and ecosystem dynamics of drylands. Results of this study show that recently deposited dust, sampled in isolated, mostly high-ground settings, is chemically and mineralogically similar on varied geologic substrates over a large area (15 000 km2) in the Mojave Desert. The silt-plus-clay fraction (fines) on these isolated surfaces is closely alike in magnetic-mineral composition, in contrast to greatly dissimilar magnetic compositions of rock surfaces of vastly different lithologies, on which the fines have accumulated. The fines, thus, are predominantly deposited dust. The amounts of potential nutrients in the sampled dust are much more uniform than might be provided by direct, local weathering of bedrock or by dust locally derived from nearby weathered products. The compositional similarity of the dust on these surfaces is interpreted to result from mixing of fines in the atmosphere as well as in fluvial, alluvial, and lacustrine depositional settings prior to dust emission.
Measurement of nicotine in household dust
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Sungroul; Department of Environmental Health Sciences, Johns Hopkins Bloomberg School of Public Health, Baltimore, MD 21205; Aung, Ther
An analytical method of measuring nicotine in house dust was optimized and associations among three secondhand smoking exposure markers were evaluated, i.e., nicotine concentrations of both house dust and indoor air, and the self-reported number of cigarettes smoked daily in a household. We obtained seven house dust samples from self-reported nonsmoking homes and 30 samples from smoking homes along with the information on indoor air nicotine concentrations and the number of cigarettes smoked daily from an asthma cohort study conducted by the Johns Hopkins Center for Childhood Asthma in the Urban Environment. House dust nicotine was analyzed by isotope dilutionmore » gas chromatography-mass spectrometry (GC/MS). Using our optimized method, the median concentration of nicotine in the dust of self-reported nonsmoking homes was 11.7 ng/mg while that of smoking homes was 43.4 ng/mg. We found a substantially positive association (r=0.67, P<0.0001) between house dust nicotine concentrations and the numbers of cigarettes smoked daily. Optimized analytical methods showed a feasibility to detect nicotine in house dust. Our results indicated that the measurement of nicotine in house dust can be used potentially as a marker of longer term SHS exposure.« less
Kamal, Atif; Malik, Riffat Naseem; Martellini, Tania; Cincinelli, Alessandra
2015-08-01
The aim of this study was to determine the abundance and distribution of polycyclic aromatic hydrocarbons (PAHs) in dust samples collected from the selected professional cooking workplaces (WCs) and residential household cooking areas (WRs), where traditional and primitive cooking practices are still prevelent. Another aim of this study was to investigate the carcinogenic risk for Pakistani human exposure to dust-bound PAHs via the routes of inhalation, ingestion, and dermal contact. Generally, the concentration of individual congeners of PAHs in surface dust samples of WC sites was higher than those measured in WR sites (p < 0.05). The benzo(a)pyrene (B(a)P), a very high carcinogenic compound, was present in the dust samples from WC sites in the highest mean concentration (630 ng g(-1) dry weight (d.w.)). The BaP mean concentration in WC workplaces was almost eight times higher than the mean value found in WR exposure sites. Moreover, the average concentration of ∑PAHs, combustion origin PAHs (∑COMB) and sum total of 7-carcinogenic PAHs (∑7-carcinogens) were also significantly higher in WC dusts samples than that in WR workplaces. Principal component analysis (PCA) and diagnostic ratios suggested coal/wood combustion as major PAH emission sources in both exposure sites. The average incremental lifetime cancer risk (ILCR) suggested a moderate to potential high cancer risk for adults and children exposed to dust-bound PAHs in both exposure sites, in particular via both dermal and ingestion contact pathways.
Witt, Emitt C; Wronkiewicz, David J; Pavlowsky, Robert T; Shi, Honglan
2013-09-01
Fugitive dust from 18 unsurfaced roadways in Missouri were sampled using a novel cyclonic fugitive dust collector that was designed to obtain suspended bulk samples for analysis. The samples were analyzed for trace metals, Fe and Al, particle sizes, and mineralogy to characterize the similarities and differences between roadways. Thirteen roads were located in the Viburnum Trend (VT) mining district, where there has been a history of contaminant metal loading of local soils; while the remaining five roads were located southwest of the VT district in a similar rural setting, but without any mining or industrial process that might contribute to trace metal enrichment. Comparison of these two groups shows that trace metal concentration is higher for dusts collected in the VT district. Lead is the dominant trace metal found in VT district dusts representing on average 79% of the total trace metal concentration, and was found moderately to strongly enriched relative to unsurfaced roads in the non-VT area. Fugitive road dust concentrations calculated for the VT area substantially exceed the 2008 Federal ambient air standard of 0.15μgm(-3) for Pb. The pattern of trace metal contamination in fugitive dust from VT district roads is similar to trace metal concentrations patterns observed for soils measured more than 40years ago indicating that Pb contamination in the region is persistent as a long-term soil contaminant. Published by Elsevier Ltd.
NASA Astrophysics Data System (ADS)
Warrier, Anish Kumar; Shankar, R.; Manjunatha, B. R.; Harshavardhana, B. G.
2014-03-01
We have used rock magnetic techniques in this study to assess atmospheric pollution at five stations in and around Mangalore city on the southwestern coast of India. Samples of dust were collected from two suburban areas (Thokkottu and Pumpwell located respectively ~ 10 km and 3 km from the city center), the city center itself (Milagres) and industrial/port areas (Panambur and Mangalore Refinery and Petrochemicals Limited (MRPL)). Low-frequency magnetic susceptibility (χlf), frequency-dependent susceptibility (χfd), susceptibility of anhysteretic remanent magnetization (χARM) and isothermal remanent magnetization (IRM 20 to 1000 mT) were determined on 23 dust samples and inter-parametric ratios calculated. Results show that samples from suburban areas (particularly Thokkottu) are characterized by low χlf (< 314.1 × 10- 8 m3 kg- 1) and up to 6% χfd, suggesting low levels of pollution and the presence of pedogenic magnetite possibly derived from soils by wind erosion. However, the average χlf of Milagres, Panambur and MRPL dust samples is high by factors of 9.2, 3.3 and 2.6 compared to that of the Thokkottu sample. The Milagres sample contains magnetically "soft" minerals like magnetite, possibly indicating its derivation from motor vehicle exhaust. In contrast, the Panambur dust sample is characterized by magnetically "hard" minerals such as hematite and goethite as it has an 8-fold higher HIRM value compared to the Thokkottu sample. This magnetic signature is perhaps the result of dust particles derived from the grinding of hematite-rich iron ore by the Kudremukh Iron Ore Company Limited (KIOCL) at Panambur and its storage and export through the nearby New Mangalore Port. However, the dust sample from MRPL has magnetically "soft" minerals like magnetite. This magnetic mineral may have originated from petroleum refining processes at MRPL. Particulate pollution from industrial activities and motor vehicle exhaust is a threat to human health and is known to cause cardiovascular and respiratory ailments. Therefore, the pollution levels brought out by this study warrant a comprehensive epidemiological study in the area of study.
Brown, F Reber; Whitehead, Todd P; Park, June-Soo; Metayer, Catherine; Petreas, Myrto X
2014-01-01
Eleven novel brominated flame retardants (NBFRs) were analyzed in dust samples from California homes as a part of the Northern California Childhood Leukemia Study (NCCLS) and from the living quarters of California fire stations as a part of the Firefighter Occupational Exposure (FOX) study using high resolution gas chromatography/mass spectrometry. The eleven NBFRs, were: α- and β-1,2-dibromo-4-(1,2-dibromoethyl)cyclohexane (α- and β-DBE-DBCH), 2-bromoallyl 2,3,6-tribromophenylether (BATE), pentabromotoluene (PBT), pentabromoethylbenzene (PBEB), 2,3-dibromopropyl 2,4,6-tribromophenyl ether (TBP-DBPE), hexabromobenzene (HBB), 2-ethylhexyl-2,3,4,5-tetrabromobenzoate (EH-TBB), 1,2-bis(2,4,6-tribromophenoxy) ethane (BTBPE), bis(2-ethylhexyl) tetrabromophthalate (BEH-TEBP), and decabromodiphenylethane (DBDPE). Six of the seven NBFRs that are produced in relatively small quantities (i.e., α−, β−DBE-DBCH, BATE, PBEB, PBT, TBP-DBPE) were measured close to or below the limit of quantitation (0.64 ng/g) in both the NCCLS and FOX samples, and the seventh, HBB, was measured at median concentrations of 1.85 ng/g and 9.40 ng/g in the NCCLS and FOX samples, respectively. The remaining four NBFRs, EH-TBB, BEH-TEBP, BTBPE, and DBDPE, are produced in higher quantities, and were detected at median concentrations of 337 ng/g, 186 ng/g, 22.3, ng/g, and 82.8 ng/g, respectively in the NCCLS samples, and at median concentrations of 2687 ng/g, 2076 ng/g, 28.4 ng/g, and 161 ng/g, respectively, in the FOX samples. Concentrations of NBFRs in the NCCLS and FOX dust samples were several times lower than concentrations of PBDEs previously measured in the same samples. Concentrations of NBFRs in the NCCLS and FOX dust samples were generally comparable to concentrations of NBFRs in other studies of house dust from the US and Canada. PMID:25261858
Compositions of modern dust and surface sediments in the Desert Southwest, United States
Reheis, M.C.; Budahn, J.R.; Lamothe, P.J.; Reynolds, R.L.
2009-01-01
Modern dusts across southwestern United States deserts are compositionally similar to dust-rich Av soil horizons (depths of 0-0.5 cm and 1-4 cm at 35 sites) for common crustal elements but distinctly different for some trace elements. Chemical compositions and magnetic properties of the soil samples are similar among sites relative to dust sources, geographic areas, and lithologic substrates. Exceptions are Li, U, and W, enriched in Owens Valley, California, and Mg and Sr, enriched in soils formed on calcareous fan gravel in southeast Nevada. The Av horizons are dominated by dust and reflect limited mixing with substrate sediments. Modern dust samples are also similar across the region, except that Owens Valley dusts are higher in Mg, Ba, and Li and dusts both there and at sites to the north on volcanic substrates are higher in Sb and W. Thus, dust and Av horizons consist of contributions from many different sources that are well mixed before deposition. Modern dusts contain significantly greater amounts of As, Cd, Cr, Cu, Ni, Pb, and Sb than do Av horizons, which record dust additions over hundreds to thousands of years. These results suggest that modern dust compositions are influenced by anthropogenic sources and emissions from Owens (dry) Lake after its artificial desiccation in 1926. Both modern dusts and Av horizons are enriched in As, Ba, Cu, Li, Sb, Th, U, and W relative to average crustal composition, which we interpret to indicate that the geologic sources of dust in the southwestern United States are geochemically distinctive.
Rock-forming metals and Pb in modern Alaskan snow
Hinkley, Todd K.
1993-01-01
Metal concentrations in annual and subannual increments of snowpack from the accumulation zone of a south central Alaska glacier indicate that the deposition of Pb with and upon snow is decoupled from that of rock dusts. Rock dusts accumulate, apparently as dry deposition, on the topmost, exposed surfaces of snowpacks in spring and summer, whereas Pb does not. Pb concentration is elevated throughout the latest one third of an annual snowpack, whereas that of rock dusts is not. For whole-year snowpacks, there is a generally sympathetic relationship among concentration of Pb, concentration of rock dust, degree of dominance of rock dusts over ocean solutes, and ferromagnesian character of the rock dusts; however, the fractional abundance of Pb in whole year samples may decrease when rock dust masses become large and/or when rock dusts dominate most strongly over salts. The metal suite chosen to characterize rock dusts and to distinguish them from ocean solutes gives detailed information about rock type of dust source areas and about the nature of the degraded rock products that are taken up, transported, and deposited by the atmosphere. Rock dusts are present at concentrations of only about 300 nanograms (ng) of dust per gram of snow in the Alaskan snowpacks. Concentrations of Pb in the Alaska snow samples are moderate, ranging from 0.1 to 0.3 ng Pb/g snow. This contrasts with larger Pb concentrations of 0.4 to 0.9 ng Pb/g snow in whole-year snowpack samples from the Sierra Nevada, California; with similar to smaller concentrations from north and south Greenland of about 0.04 ng Pb/g snow or less, and about 0.2 ng Pb/g snow or less, respectively, and with much smaller concentrations from Antarctica, now believed to range from a minimum of about 0.001 to a maximum of 0.005 (or 0.01) ng Pb/g snow.
Stres, Blaz; Sul, Woo Jun; Murovec, Bostjan; Tiedje, James M.
2013-01-01
Background The Himalaya with its altitude and geographical position forms a barrier to atmospheric transport, which produces much aqueous-particle monsoon precipitation and makes it the largest continuous ice-covered area outside polar regions. There is a paucity of data on high-altitude microbial communities, their native environments and responses to environmental-spatial variables relative to seasonal and deglaciation events. Methodology/Principal Findings Soils were sampled along altitude transects from 5000 m to 6000 m to determine environmental, spatial and seasonal factors structuring bacterial communities characterized by 16 S rRNA gene deep sequencing. Dust traps and fresh-snow samples were used to assess dust abundance and viability, community structure and abundance of dust associated microbial communities. Significantly different habitats among the altitude-transect samples corresponded to both phylogenetically distant and closely-related communities at distances as short as 50 m showing high community spatial divergence. High within-group variability that was related to an order of magnitude higher dust deposition obscured seasonal and temporal rearrangements in microbial communities. Although dust particle and associated cell deposition rates were highly correlated, seasonal dust communities of bacteria were distinct and differed significantly from recipient soil communities. Analysis of closest relatives to dust OTUs, HYSPLIT back-calculation of airmass trajectories and small dust particle size (4–12 µm) suggested that the deposited dust and microbes came from distant continental, lacustrine and marine sources, e.g. Sahara, India, Caspian Sea and Tibetan plateau. Cyanobacteria represented less than 0.5% of microbial communities suggesting that the microbial communities benefitted from (co)deposited carbon which was reflected in the psychrotolerant nature of dust-particle associated bacteria. Conclusions/Significance The spatial, environmental and temporal complexity of the high-altitude soils of the Himalaya generates ongoing disturbance and colonization events that subject heterogeneous microniches to stochastic colonization by far away dust associated microbes and result in the observed spatially divergent bacterial communities. PMID:24086740
High exposure to respirable dust and quartz in a labour-intensive coal mine in Tanzania.
Mamuya, Simon H D; Bråtveit, Magne; Mwaiselage, Julius; Mashalla, Yohana J S; Moen, Bente E
2006-03-01
Labour-intensive mines are numerous in several developing countries, but dust exposure in such mines has not been adequately characterized. The aim of this study was to identify and quantify the determinants of respirable dust and quartz exposure among underground coal mine workers in Tanzania. Personal respirable dust samples (n = 134) were collected from 90 underground workers in June-August 2003 and July-August 2004. The development team had higher exposure to respirable dust and quartz (geometric means 1.80 and 0.073 mg m(-3), respectively) than the mining team (0.47 and 0.013 mg m(-3)), the underground transport team (0.14 and 0.006 mg m(-3)) and the underground maintenance team (0.58 and 0.016 mg m(-3)). The percentages of samples above the threshold limit values (TLVs) of 0.9 mg m(-3) for respirable bituminous coal dust and 0.05 mg m(-3) for respirable quartz, respectively, were higher in the development team (55 and 47%) than in the mining team (20 and 9%). No sample for the underground transport team exceeded the TLV. Drilling in the development was the work task associated with the highest exposure to respirable dust and quartz (17.37 and 0.611 mg m(-3), respectively). Exposure models were constructed using multiple regression model analysis, with log-transformed data on either respirable dust or quartz as the dependent variable and tasks performed as the independent variables. The models for the development section showed that blasting and pneumatic drilling times were major determinants of respirable dust and quartz, explaining 45.2 and 40.7% of the variance, respectively. In the mining team, only blasting significantly determined respirable dust. Immediate actions for improvements are suggested to include implementing effective dust control together with improved training and education programmes for the workers. Dust and quartz in this underground mine should be controlled by giving priority to workers performing drilling and blasting in the development sections of the mine.
Dust Mites Population in Indoor Houses of Suspected Allergic Patients of South Assam, India
Sharma, Dhruba; Dutta, B. K.; Singh, A. B.
2011-01-01
Background. In the present study, quality and quantity of indoor dust mites was evaluated at the residence of 150 atopic allergic patients from four different districts of South Assam. Methods. Suspected patients with case history of allergic disease were selected for indoor survey. Dust samples (500 mg) were collected from the selected patient's house and were analyzed using standard methods. Results. About 60% of the selected patients were found suffering from respiratory disorders and rest 40% from skin allergy. The dominant mites recorded from indoor dust samples were Dermatophagoides followed by Blomia, Acarus, and Cheyletus while Caloglyphus was recorded in least number. The distribution of mites on the basis of housing pattern indicates that RCC type of buildings supports maximum dust mite's population followed by Assam type (semi-RCC) buildings, and the lowest count was observed in wooden houses. Environmental factors like temperature, rainfall, and relative humidity are found to determine the indoor mite's population. Severity of allergic attack in some of the typical cases was found to be proportional to the allergen load of mites in the dust samples. Conclusions. The economic status, housing pattern, and local environmental factors determine the diversity and abundance of dust mites in indoor environment. PMID:23724231
Imaging-based dust sensors: equipment and methods
NASA Astrophysics Data System (ADS)
Bonifazi, Giuseppe; Greco, Sonia
2004-05-01
Dust detection and control in real time, represent one of the most challenging problem in all those environments where fine and ultrafine airborne particulate solids products are present. The presence of such products can be linked to several factors, often directly related and influenced by the working-production actions performed. Independently from the causes generating dust, airborne contaminants are an occupational problem of increasing interest as they are related to a wide number of diseases. In particular, airborne dusts are well known to be associated with several classical occupational lung diseases, such as the pneumoconiosis, especially at high levels of exposure. Nowadays there is also an increasing interest in other dust related diseases, from the most serious as cancer and asthma, to those related with allergies or irritation and other illnesses, also occurring at lower levels of exposure. Among the different critical factors influencing health risk for airborne dust exposure, mainly four have to be considered, that is: i) nature of the dust resulting from working in terms of presence of specific poisoning material, i.e. free silica, and morphological and morphometrical attributes of particulates constituting airborne dust; ii) size of the particles, iii) duration of exposure time and, finally, iv) airborne dust concentration in the breathing zone where the worker performs his activity. A correct dust detection is not easy, especially if some of the previous mentioned factors, have to be detected and quantified in real time in order to define specific "on-line" control actions aimed to reduce the level of the exposure to dust of the workers, as for example: i) modification of aspirating devices operating condition, change of filtering cleaning sequence, etc. . The more severe are the environmental conditions, in terms of dust presence (in quantity and quality) more difficult is to utilize efficient sampling devices. Detection devices, in fact, tend to become "blind" to dust as dust presence increases, on the other hand severe dust production conditions is exactly the case where control strategies have to be applied to realize safer conditions for the workers. In this paper the possibility to utilize a new logic to perform an "on-line" airborne dust sampling and analysis utilizing imaging is described with particular reference to dusts flowing in a duct after the caption and before their abatement by classical mechanical filtering. The study was particularly addressed to define, design and implement a logic able to extract those parameters affecting airborne dust behavior with respect to its efficient abatement. All dust sampling was performed directly in an industrial plant where tests were carried out in a controlled environment.
Hamscher, Gerd; Pawelzick, Heike Theresia; Sczesny, Silke; Nau, Heinz; Hartung, Jörg
2003-10-01
Pig-house dust originates from feed, bedding, feces, and the animals themselves. If the animals receive drugs such as antibiotics, residues of these substances may occur in manure, in the air, or on surfaces of the respective animal house. In a retrospective study, we investigated dust samples collected during two decades from the same piggery for the occurrence of various antibiotics. In 90% of these samples, we detected up to five different antibiotics, including tylosin, various tetracyclines, sulfamethazine, and chloramphenicol, in total amounts up to 12.5 mg/kg dust. High dust exposure in animal confinement buildings is believed to be a respiratory health hazard because of the high content of microorganisms, endotoxins, and allergens. Further risks may arise from the inhalation of dust contaminated with a cocktail of antibiotics. Apart from that, our data provide first evidence for a new route of entry for veterinary drugs in the environment.
'Nuisance Dust' - a Case for Recalibration?
NASA Astrophysics Data System (ADS)
Datson, Hugh; Marker, Brian
2013-04-01
This paper considers the case for a review and recalibration of limit values and acceptability criteria for 'nuisance dust', a widely encountered but poorly defined and regulated aspect of particulate matter pollution. Specific dust fractions such as PM10 and asbestiforms are well characterised and have limit values enshrined in legislation. National, and international, limit values for acceptable concentrations of PM10 and other fractions of particulate matter have been defined and agreed. In the United Kingdom (UK), these apply to both public and workplace exposures. By contrast, there is no standard definition or universal criteria against which acceptable levels for 'nuisance dust' can be assessed. This has implications for land-use planning and resource utilisation. Without meaningful limit values, inappropriate development might take place too near to residential dwellings or land containing economically important mineral resources may be effectively sterilised. Furthermore, the expression 'nuisance dust' is unhelpful in that 'nuisance' has a specific meaning in environmental law whilst 'nuisance dust' is often taken to mean 'generally visible particulate matter'. As such, it is associated with the social and broader environmental impacts of particulate matter. PM10 concentrations are usually expressed as a mass concentration over time. These can be determined using a range of techniques. While results from different instruments are generally comparable, data obtained from alternative methods for measuring 'nuisance dust' are rarely interchangeable. In the UK, many of the methods typically used are derived from approaches developed under the HMIP (Her Majesty's Inspectorate of Pollution) regime in the 1960s onwards. Typical methods for 'nuisance dust' sampling focus on measurement of dust mass (from the weight of dust collected in an open container over time) or dust soiling (from loss of reflectance and or obscuration of a surface discoloured by dust over time). 'Custom and practice' acceptance criteria for dust samples obtained by mass or soiling techniques have been developed and are widely applied even though they were not necessarily calibrated thoroughly and have not been reviewed recently. Furthermore, as sampling techniques have evolved, criteria developed for one method have been adapted for another. Criteria and limit values have sometimes been based on an insufficient knowledge of sampler characteristics. Ideally, limit values should be calibrated for the locality to take differences in dust density and visibility into account. Work is needed on the definition of criteria and limit values, and sampling practices for coarse dust fractions, followed by discussion of good practices for securing effective monitoring that is proportionate and fit for purpose. With social changes and the evolution of environmental controls since the 1960s, the public perception of 'nuisance dust' has changed and needs to be addressed by reviewing existing thresholds in relation to the range of monitoring devices currently in use.