Performance of Radiant Heating Systems of Low-Energy Buildings
NASA Astrophysics Data System (ADS)
Sarbu, Ioan; Mirza, Matei; Crasmareanu, Emanuel
2017-10-01
After the introduction of plastic piping, the application of water-based radiant heating with pipes embedded in room surfaces (i.e., floors, walls, and ceilings), has significantly increased worldwide. Additionally, interest and growth in radiant heating and cooling systems have increased in recent years because they have been demonstrated to be energy efficient in comparison to all-air distribution systems. This paper briefly describes the heat distribution systems in buildings, focusing on the radiant panels (floor, wall, ceiling, and floor-ceiling). Main objective of this study is the performance investigation of different types of low-temperature heating systems with different methods. Additionally, a comparative analysis of the energy, environmental, and economic performances of floor, wall, ceiling, and floor-ceiling heating using numerical simulation with Transient Systems Simulation (TRNSYS) software is performed. This study showed that the floor-ceiling heating system has the best performance in terms of the lowest energy consumption, operation cost, CO2 emission, and the nominal boiler power. The comparison of the room operative air temperatures and the set-point operative air temperature indicates also that all radiant panel systems provide satisfactory results without significant deviations.
An, Jae-Yoon; Kim, Sumin; Kim, Hyun-Joong
2011-03-15
Formaldehyde was measured with a desiccator, a 20 L chamber and the FLEC method. The formaldehyde emission rate from laminate was the highest at 32 °C using the desiccator, which then decreased with time. The formaldehyde emission using the 20 L small chamber and FLEC showed a similar tendency. There was a strong correlation between the formaldehyde and total volatile organic compounds (TVOCs) with both types of floorings using the two different methods. The formaldehyde emission rate and TVOC results were higher when tested using the FLEC method than with the 20 L small chamber method. The emission rate was affected by the joint edge length in laminate flooring. Toluene, ethylbenzene and xylene were the main VOCs emitted from laminate flooring, and there were more unidentified VOCs emitted than identified VOCs. The samples heated with a floor heating system emitted more formaldehyde than those heated using an air circulation system due to the temperature difference between the bottom panel and flooring. The TVOC emission level of the samples was higher when an air circulation system was used than when a floor heating system was used due to the high ventilation rate. Copyright © 2010 Elsevier B.V. All rights reserved.
Hashiguchi, Nobuko; Tochihara, Yutaka; Ohnaka, Tadakatsu; Tsuchida, Chiaki; Otsuki, Tamio
2004-11-01
The purpose of this study was to investigate the effects of a floor heating and air conditioning system on thermal responses of the elderly. Eight elderly men and eight university students sat for 90 minutes in a chair under the following 3 conditions: air conditioning system (A), floor heating system (F) and no heating system (C). The air temperature of sitting head height for condition A was 25 degrees C, and the maximum difference in vertical air temperature was 4 degrees C. The air and floor temperature for condition F were 21 and 29 degrees C, respectively. The air temperature for condition C was 15 degrees C. There were no significant differences in rectal temperature and mean skin temperature between condition A and F. Systolic blood pressure of the elderly men in condition C significantly increased compared to those in condition A and F. No significant differences in systolic blood pressure between condition A and F were found. The percentage of subjects who felt comfortable under condition F was higher than that of those under condition A in both age groups, though the differences between condition F and A was not significant. Relationships between thermal comfort and peripheral (e.g., instep, calf, hand) skin temperature, and the relationship between thermal comfort and leg thermal sensation were significant for both age groups. However, the back and chest skin temperature and back thermal sensation for the elderly, in contrast to that for the young, was not significantly related to thermal comfort. These findings suggested that thermal responses and physiological strain using the floor heating system did not significantly differ from that using the air conditioning system, regardless of the subject age and despite the fact that the air temperature with the floor heating system was lower. An increase in BP for elderly was observed under the condition in which the air temperature was 15 degrees C, and it was suggested that it was necessary for the elderly people to heat the room somehow in winter. Moreover, it is particularly important for elderly people to avoid a decrease in peripheral skin temperature, and maintain awareness of the warmth of peripheral areas, such as the leg, in order to ensure thermal comfort.
Migration of DEHP and DINP into dust from PVC flooring products at different surface temperature.
Jeon, Seunghwan; Kim, Ki-Tae; Choi, Kyungho
2016-03-15
Phthalates are important endocrine disrupting chemicals that have been linked to various adverse human health effects. Phthalates are ubiquitously present in indoor environment and could enter humans. Vinyl or PVC floorings have been recognized as one of important sources of phthalate release to indoor environment including house dust. In the present study, we estimated the migration of di(2-ethylhexyl)phthalate (DEHP) and di-isononyl phthalate (DINP) from the flooring materials into the dust under different heating conditions. For this purpose, a small chamber specifically designed for the present study and a Field and Laboratory Emission Cell (FLEC) were used, and four major types of PVC flooring samples including two UV curing paint coated, an uncoated residential, and a wax-coated commercial type were tested. Migration of DEHP was observed for an uncoated residential type and a wax-coated commercial type flooring. After 14 days of incubation, the levels of DEHP in the dust sample was determined at room temperature on average (standard deviation) at 384 ± 19 and 481 ± 53 μg/g, respectively. In contrast, migration of DINP was not observed. The migration of DEHP was strongly influenced by surface characteristics such as UV curing coating. In the residential flooring coated with UV curing paint, migration of DEHP was not observed at room temperature. But under the heated condition, the release of DEHP was observed in the dust in the FLEC. Migration of DEHP from flooring materials increased when the flooring was heated (50 °C). In Korea, heated flooring system, or 'ondol', is very common mode of heating in residential setting, therefore the contribution of PVC flooring to the total indoor DEHP exposure among general population is expected to be greater especially during winter season when the floor is heated. Copyright © 2015 Elsevier B.V. All rights reserved.
McGlone, J J; Stansbury, W F; Tribble, L F
1988-04-01
Two experiments using 120 sows were conducted to determine the effects during heat stress of two floor types, snout coolers or a water drip system, and a high energy-density diet. During both studies, air temperature was maintained at or above 29 degrees C. Floor types included partially slotted concrete and plastic-coated, expanded metal. In Exp. 1, in addition to floor-type treatments, snout coolers were on or off and the water drip was on for 3 min each 10 min or off. Snout coolers increased (P less than .05) sow feed intake and decreased (P less than .05) sow lactation weight loss. Water drip increased (P less than .002) sow feed intake and reduced lactation weight loss. The drip X floor-type interaction was significant for most measures of piglet performance. Drip was beneficial for piglet weights when piglets were on plastic, whereas drip was detrimental to piglet performance while they were housed on concrete. In Exp. 2, two floor types, drip or no-drip and a high energy-density diet or control diet were examined during heat stress. The high energy-density diet reduced (P less than .01) sow feed intake but provided no measurable increase in piglet performance during heat stress. We conclude that water drip is an effective cooling technique for heat-stressed sows, especially when floors are plastic. Snout coolers, partial concrete slots and high energy-density diets provided only minor benefits to heat-stressed sows and were not of benefit to piglets nursing heat-stressed sows.
7 CFR 1721.104 - Eligible purposes.
Code of Federal Regulations, 2014 CFR
2014-01-01
... measures: (i) Caulking; (ii) Weather-stripping; (iii) Heat pump systems (including water source heat pumps); (iv) Heat pumps, water heaters, and central heating or central air conditioning system replacements or modifications, which reduce energy consumption; (v) Ceiling insulation; (vi) Wall insulation; (vii) Floor...
7 CFR 1721.104 - Eligible purposes.
Code of Federal Regulations, 2012 CFR
2012-01-01
... measures: (i) Caulking; (ii) Weather-stripping; (iii) Heat pump systems (including water source heat pumps); (iv) Heat pumps, water heaters, and central heating or central air conditioning system replacements or modifications, which reduce energy consumption; (v) Ceiling insulation; (vi) Wall insulation; (vii) Floor...
7 CFR 1721.104 - Eligible purposes.
Code of Federal Regulations, 2010 CFR
2010-01-01
... measures: (i) Caulking; (ii) Weather-stripping; (iii) Heat pump systems (including water source heat pumps); (iv) Heat pumps, water heaters, and central heating or central air conditioning system replacements or modifications, which reduce energy consumption; (v) Ceiling insulation; (vi) Wall insulation; (vii) Floor...
7 CFR 1721.104 - Eligible purposes.
Code of Federal Regulations, 2013 CFR
2013-01-01
... measures: (i) Caulking; (ii) Weather-stripping; (iii) Heat pump systems (including water source heat pumps); (iv) Heat pumps, water heaters, and central heating or central air conditioning system replacements or modifications, which reduce energy consumption; (v) Ceiling insulation; (vi) Wall insulation; (vii) Floor...
7 CFR 1721.104 - Eligible purposes.
Code of Federal Regulations, 2011 CFR
2011-01-01
... measures: (i) Caulking; (ii) Weather-stripping; (iii) Heat pump systems (including water source heat pumps); (iv) Heat pumps, water heaters, and central heating or central air conditioning system replacements or modifications, which reduce energy consumption; (v) Ceiling insulation; (vi) Wall insulation; (vii) Floor...
Sandwich Core Heat-Pipe Radiator for Power and Propulsion Systems
NASA Technical Reports Server (NTRS)
Gibson, Marc; Sanzi, James; Locci, Ivan
2013-01-01
Next-generation heat-pipe radiator technologies are being developed at the NASA Glenn Research Center to provide advancements in heat-rejection systems for space power and propulsion systems. All spacecraft power and propulsion systems require their waste heat to be rejected to space in order to function at their desired design conditions. The thermal efficiency of these heat-rejection systems, balanced with structural requirements, directly affect the total mass of the system. Terrestrially, this technology could be used for thermal control of structural systems. One potential use is radiant heating systems for residential and commercial applications. The thin cross section and efficient heat transportability could easily be applied to flooring and wall structures that could evenly heat large surface areas. Using this heat-pipe technology, the evaporator of the radiators could be heated using any household heat source (electric, gas, etc.), which would vaporize the internal working fluid and carry the heat to the condenser sections (walls and/or floors). The temperature could be easily controlled, providing a comfortable and affordable living environment. Investigating the appropriate materials and working fluids is needed to determine this application's potential success and usage.
7 CFR Exhibit D to Subpart A of... - Thermal Performance Construction Standards
Code of Federal Regulations, 2013 CFR
2013-01-01
... floor insulation, the total heat loss attributed to the floor from the heated area shall not exceed the heat loss calculated for floors with required insulation. AInsulation may be omitted from floors over.... Definitions A. British thermal unit (Btu) means the quantity of heat required to raise the temperature of one...
7 CFR Exhibit D to Subpart A of... - Thermal Performance Construction Standards
Code of Federal Regulations, 2014 CFR
2014-01-01
... floor insulation, the total heat loss attributed to the floor from the heated area shall not exceed the heat loss calculated for floors with required insulation. AInsulation may be omitted from floors over.... Definitions A. British thermal unit (Btu) means the quantity of heat required to raise the temperature of one...
7 CFR Exhibit D to Subpart A of... - Thermal Performance Construction Standards
Code of Federal Regulations, 2012 CFR
2012-01-01
... floor insulation, the total heat loss attributed to the floor from the heated area shall not exceed the heat loss calculated for floors with required insulation. AInsulation may be omitted from floors over.... Definitions A. British thermal unit (Btu) means the quantity of heat required to raise the temperature of one...
7 CFR Exhibit D to Subpart A of... - Thermal Performance Construction Standards
Code of Federal Regulations, 2011 CFR
2011-01-01
... floor insulation, the total heat loss attributed to the floor from the heated area shall not exceed the heat loss calculated for floors with required insulation. AInsulation may be omitted from floors over.... Definitions A. British thermal unit (Btu) means the quantity of heat required to raise the temperature of one...
7 CFR Exhibit D to Subpart A of... - Thermal Performance Construction Standards
Code of Federal Regulations, 2010 CFR
2010-01-01
... floor insulation, the total heat loss attributed to the floor from the heated area shall not exceed the heat loss calculated for floors with required insulation. AInsulation may be omitted from floors over.... Definitions A. British thermal unit (Btu) means the quantity of heat required to raise the temperature of one...
Elevated waterproof access floor system and method of making the same
NASA Technical Reports Server (NTRS)
Cohen, Marc M. (Inventor)
1987-01-01
An elevated waterproof access floor system having subfloor channels or compartments for power lines, gas lines or the like is adapted such that it can be opened and subsequently resealed without destroying the waterproofing and without destroying its aesthetic appearance. A multiplicity of tiles are supported on a support grid, and a flooring sheet is supported on the tiles. Attachment means are provided to prevent lateral but not vertical movement of the flooring sheet with respect to the tiles so that the flooring sheet can be lifted off the tiles, but when the flooring sheet is supported on the tiles, no lateral slipping will occur. The flooring sheet is made of a heat resealable material, so that it can be cut away in sections, and the tiles therebelow lifted off, to provide access to subfloor compartments.
The effect of sub-floor heating on house-dust-mite populations on floors and in furniture.
de Boer, Rob
2003-01-01
It is well known that dehydrating conditions for house dust mites can be created by simply raising the temperature, causing loss of body water and eventually death. Thus, it can be expected that conditions for dust mites are less favourable on floors supplied with sub-floor heating. This was examined in a study of 16 houses with sub-floor heating and 21 without. The pattern of changes in air humidity and temperature on the floors was investigated and compared to known data of the tolerance of dust mites. Also the resident mite populations were compared. Floors with sub-floor heating had, on average, fewer mites, but the difference with unheated floors was small. It was remarkable that mite numbers were also lower in upholstered furniture. Another important observation was that some houses with sub-floor heating had high mite numbers, indicating that this type of heating is compatible with a thriving mite population. Temperature and humidity conditions of heated floors may allow mites not only to survive, but also to remain active in winter. A moderate increase in temperature, a moderate decrease in (absolute) air humidity, or a combination of both, will suffice to keep the humidity all winter below the Critical Equilibrium Humidity, the level of air humidity that is critical for mite growth and reproduction, hence for allergen production. However, it is argued that measures to suppress allergen production by house dust mites are likely to be far more effective if taken in summer rather than in winter.
Limited energy study, Buildings 750 and 798, Fort Richardson, Alaska. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-02-01
The purpose of this study is to identify and evaluate Energy Conservation Opportunities (ECOs) for two motor pool facilities, Buildings 750 and 798, to determine their energy savings potential, economic feasibility, and to document results for possible future funding. Buildings 750 and 798 are heated by steam supplied from a central plant. The central plant uses natural gas as a primary fuel source to produce steam for both heating and electrical energy generation. Since power is produced on the base there is not a demand charge for electrical energy. Two ECOs examined the use of natural gas in conjunction withmore » steam as a method of heating the buildings. Annual baseline energy consumption and cost data for each building is presented. The heating system in Building 750 was found to be severely under capacity. This is the result of the disabling of the under-floor heating system and the roof top MAUs. Building 798 also has had the under-floor heating system disabled. However, baseline simulations show that the remaining system is capable of maintaining thermostat setpoints during all but the coldest days of a typical year.« less
On buoyancy-driven natural ventilation of a room with a heated floor
NASA Astrophysics Data System (ADS)
Gladstone, Charlotte; Woods, Andrew W.
2001-08-01
The natural ventilation of a room, both with a heated floor and connected to a cold exterior through two openings, is investigated by combining quantitative models with analogue laboratory experiments. The heated floor generates an areal source of buoyancy while the openings allow displacement ventilation to operate. When combined, these produce a steady state in which the air in the room is well-mixed, and the heat provided by the floor equals the heat lost by displacement. We develop a quantitative model describing this process, in which the advective heat transfer through the openings is balanced with the heat flux supplied at the floor. This model is successfully tested with observations from small-scale analogue laboratory experiments. We compare our results with the steady-state flow associated with a point source of buoyancy: for a given applied heat flux, an areal source produces heated air of lower temperature but a greater volume flux of air circulates through the room. We generalize the model to account for the effects of (i) a cooled roof as well as a heated floor, and (ii) an external wind or temperature gradient. In the former case, the direction of the flow through the openings depends on the temperature of the exterior air relative to an averaged roof and floor temperature. In the latter case, the flow is either buoyancy dominated or wind dominated depending on the strength of the pressure associated with the wind. Furthermore, there is an intermediate multiple-solution regime in which either flow regime may develop.
Solar heating and hot water system installed at Shoney's Restaurant, North Little Rock, Arkansas
NASA Technical Reports Server (NTRS)
1980-01-01
A solar heating system designed to supply a major portion of the space and water heating requirements for a restaurant is described. The restaurant has a floor space of approximately 4,650 square feet and requires approximate 1500 gallons of hot water daily. The solar energy system consists of 1,428 square feet of Chamberlain flat plate liquid collector subsystem, and a 1500 gallon storage subsystem circulating hot water producing 321 x 10 to the 6th power Btu/Yr (specified) building heating and hot water heating.
Solar heating and hot water system installed at Shoney's Restaurant, North Little Rock, Arkansas
NASA Astrophysics Data System (ADS)
1980-08-01
A solar heating system designed to supply a major portion of the space and water heating requirements for a restaurant is described. The restaurant has a floor space of approximately 4,650 square feet and requires approximate 1500 gallons of hot water daily. The solar energy system consists of 1,428 square feet of Chamberlain flat plate liquid collector subsystem, and a 1500 gallon storage subsystem circulating hot water producing 321 x 10 to the 6th power Btu/Yr (specified) building heating and hot water heating.
Solar Space and Water Heating for School -- Dallas, Texas
NASA Technical Reports Server (NTRS)
1982-01-01
90 page report gives overview of retrofitted solar space-heating and hot-water system installation for 61-year-old high school. Description, specifications, modifications, plan drawings for roof, three floors, basement, correspondence, and documents are part of report.
Comparative Cooling Season Performance of Air Distribution Systems in Multistory Townhomes
DOE Office of Scientific and Technical Information (OSTI.GOV)
A. Poerschke; Beach, R.; Beggs, T.
2016-08-26
IBACOS investigated the performance of a small-diameter high velocity heat pump system compared to a conventional system in a new construction triplex townhouse. A ductless heat pump system also was installed for comparison, but the homebuyer backed out because of aesthetic concerns about that system. In total, two buildings, having identical solar orientation and comprised of six townhomes, were monitored for comfort and energy performance. Results show that the small-diameter system provides more uniform temperatures from floor to floor in the three-story townhome. No clear energy consumption benefit was observed from either system. The builder is continuing to explore themore » small-diameter system as its new standard system to provide better comfort and indoor air quality. The homebuilder also explored the possibility of shifting its townhome product to meet the U.S. Department of Energy Challenge Home National Program Requirements.« less
Abd El-Wahab, A; Beineke, A; Beyerbach, M; Visscher, C F; Kamphues, J
2011-09-01
Actions concerning animal health in turkey production are coming more and more to the fore. Litter quality has a great impact on the bird's health and welfare. This study aimed at evaluating the effects of using floor heating, different litter materials, and exposure to litter with a "critical moisture content" of 35% for 16 or 24 hr/day on the severity of foot pad dermatitis (FPD), a widespread disease in fattening turkeys. Four groups of 2-wk-old female turkeys, with 20 birds in each, were reared during 3 wk. All turkeys were fed a commercial pellet diet ad libitum. The first two groups were kept on wood shavings (35% moisture) without and with floor heating. The other two groups were housed on lignocellulose (Soft Cell) of 35% moisture without and with floor heating. In each group, half of the birds were housed for 8 hr/day in adjacent separate boxes where the litter was kept clean and dry throughout the experimental period. Foot pads were assessed weekly for external and at day 35 for histopathologic scoring (scores: 0 = healthy; 7 = ulcer). At day 14 each bird had normal and healthy foot pads. The results indicate that using floor heating resulted in significantly lower FPD scores (0.8 +/- 0.2) compared to groups without floor heating (2.0 +/- 0.8). Using lignocellulose as a litter material resulted in significantly lower histopathologic FPD scores (1.4 +/- 0.7) compared with wood shavings (1.7 +/- 0.8). In all birds housed on dry litter for 8 hr/day, significantly lower FPD scores were found compared to birds housed on wet litter for 24 hr. In conclusion, using floor heating, even with wet litter (35% moisture), independent of the litter type, resulted in reduced severity of FPD compared to those birds housed in pens without using floor heating. Additionally, using lignocellulose as a litter material resulted in lower FPD compared with wood shavings. Keeping litter dry and "warm" could be achieved by using floor heating, which is considered a practical step to enhance animal health and welfare.
Nuclear reactor cavity floor passive heat removal system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Edwards, Tyler A.; Neeley, Gary W.; Inman, James B.
A nuclear reactor includes a reactor core disposed in a reactor pressure vessel. A radiological containment contains the nuclear reactor and includes a concrete floor located underneath the nuclear reactor. An ex vessel corium retention system includes flow channels embedded in the concrete floor located underneath the nuclear reactor, an inlet in fluid communication with first ends of the flow channels, and an outlet in fluid communication with second ends of the flow channels. In some embodiments the inlet is in fluid communication with the interior of the radiological containment at a first elevation and the outlet is in fluidmore » communication with the interior of the radiological containment at a second elevation higher than the first elevation. The radiological containment may include a reactor cavity containing a lower portion of the pressure vessel, wherein the concrete floor located underneath the nuclear reactor is the reactor cavity floor.« less
Code of Federal Regulations, 2012 CFR
2012-10-01
... Flammability of Flexible Cellular Materials Using a Radiant Heat Energy Source. (v) ASTM E 119-00a, Standard... Method for Surface Flammability of Materials Using a Radiant Heat Energy Source. (vii) ASTM E 648-00, Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source...
Code of Federal Regulations, 2013 CFR
2013-10-01
... Flammability of Flexible Cellular Materials Using a Radiant Heat Energy Source. (v) ASTM E 119-00a, Standard... Method for Surface Flammability of Materials Using a Radiant Heat Energy Source. (vii) ASTM E 648-00, Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source...
Code of Federal Regulations, 2011 CFR
2011-10-01
... Flammability of Flexible Cellular Materials Using a Radiant Heat Energy Source. (v) ASTM E 119-00a, Standard... Method for Surface Flammability of Materials Using a Radiant Heat Energy Source. (vii) ASTM E 648-00, Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source...
Code of Federal Regulations, 2014 CFR
2014-10-01
... Flammability of Flexible Cellular Materials Using a Radiant Heat Energy Source. (v) ASTM E 119-00a, Standard... Method for Surface Flammability of Materials Using a Radiant Heat Energy Source. (vii) ASTM E 648-00, Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source...
2002-10-01
proximity to this aluminum bar, then the aluminum element would serve as a heat pipe to rapidly distribute heat to the center sensor and the floor...for a Bent Square Pipe ......................................................... 86 7.3 One-Cell Model for Free Surface Flows...90 7.4.2 Filament Application for Fluid Heating in Microreactor...................................... 91 7.4.3 Model
39. FOURTH FLOOR: DETAIL OF STEAM HEATING PIPES ON NORTHEAST ...
39. FOURTH FLOOR: DETAIL OF STEAM HEATING PIPES ON NORTHEAST WALL OF DINING AND SOCIAL HALL ON NORTHWEST END OF BUILDING LOOKING NORTHEAST - Masonic Temple, 1111-1119 Eleventh Street, Altoona, Blair County, PA
Ahearn, D G; Crow, S A; Simmons, R B; Price, D L; Noble, J A; Mishra, S K; Pierson, D L
1996-05-01
Complaints characteristic of those for sick building syndrome prompted mycological investigations of a modern multi-story office building on the Gulf coast in the Southeastern United States (Houston-Galveston area). The air handling units and fiberglass duct liner of the heating, ventilating and air conditioning system of the building, without a history of catastrophic or chronic water damage, demonstrated extensive colonization with Penicillium spp and Cladosporium herbarum. Although dense fungal growth was observed on surfaces within the heating-cooling system, most air samples yielded fewer than 200 CFU m-3. Several volatile compounds found in the building air were released also from colonized fiberglass. Removal of colonized insulation from the floor receiving the majority of complaints of mouldy air and continuous operation of the units supplying this floor resulted in a reduction in the number of complaints.
NASA Technical Reports Server (NTRS)
Ahearn, D. G.; Crow, S. A.; Simmons, R. B.; Price, D. L.; Noble, J. A.; Mishra, S. K.; Pierson, D. L.
1996-01-01
Complaints characteristic of those for sick building syndrome prompted mycological investigations of a modern multi-story office building on the Gulf coast in the Southeastern United States (Houston-Galveston area). The air handling units and fiberglass duct liner of the heating, ventilating and air conditioning system of the building, without a history of catastrophic or chronic water damage, demonstrated extensive colonization with Penicillium spp and Cladosporium herbarum. Although dense fungal growth was observed on surfaces within the heating-cooling system, most air samples yielded fewer than 200 CFU m-3. Several volatile compounds found in the building air were released also from colonized fiberglass. Removal of colonized insulation from the floor receiving the majority of complaints of mouldy air and continuous operation of the units supplying this floor resulted in a reduction in the number of complaints.
32 CFR 644.450 - Items excluded from usual restoration obligation.
Code of Federal Regulations, 2011 CFR
2011-07-01
... gypsum block walls. (3) Floor joints, roof trusses (including roof boards and roofing), and framing..., ventilators, and metal ceilings. (8) Structural steel or iron. (9) Fire escapes. (10) Heating systems. (11...
32 CFR 644.450 - Items excluded from usual restoration obligation.
Code of Federal Regulations, 2010 CFR
2010-07-01
... gypsum block walls. (3) Floor joints, roof trusses (including roof boards and roofing), and framing..., ventilators, and metal ceilings. (8) Structural steel or iron. (9) Fire escapes. (10) Heating systems. (11...
Comparative Cooling Season Performance of Air Distribution Systems in Multistory Townhomes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poerschke, Andrew; Beach, Rob; Beggs, Timothy
2016-08-01
IBACOS investigated the performance of a small-diameter high velocity heat pump system compared to a conventional system in a new construction triplex townhouse. A ductless heat pump system also was installed for comparison, but the homebuyer backed out because of aesthetic concerns about that system. In total, two buildings, having identical solar orientation and comprised of six townhomes, were monitored for comfort and energy performance. Results show that the small-diameter system provides more uniform temperatures from floor to floor in the three-story townhome. No clear energy consumption benefit was observed from either system. The builder is continuing to explore themore » small-diameter system as its new standard system to provide better comfort and indoor air quality. The homebuilder also explored the possibility of shifting its townhome product to meet the U.S. Department of Energy Challenge Home National Program Requirements. Ultimately, the builder decided that adoption of these practices would be too disruptive midstream in the construction cycle. However, the townhomes met the ENERGY STAR Version 3.0 program requirements.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
IBACOS investigated the performance of a small-diameter high velocity heat pump system compared to a conventional system in a new construction triplex townhouse. A ductless heat pump system also was installed for comparison, but the homebuyer backed out because of aesthetic concerns about that system. In total, two buildings, having identical solar orientation and comprised of six townhomes, were monitored for comfort and energy performance. Results show that the small-diameter system provides more uniform temperatures from floor to floor in the three-story townhome. No clear energy consumption benefit was observed from either system. The builder is continuing to explore themore » small-diameter system as its new standard system to provide better comfort and indoor air quality. The homebuilder also explored the possibility of shifting its townhome product to meet the U.S. Department of Energy Challenge Home National Program Requirements. Ultimately, the builder decided that adoption of these practices would be too disruptive midstream in the construction cycle. However, the townhomes met the ENERGY STAR Version 3.0 program requirements.« less
Steamer of steam circulation system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Onodera, M.
1986-09-23
A conveyor steamer is described which consists of: a room enclosed with heat-insulated walls, floor, and ceiling, the room having an entrance and an exit for goods to be steamed, a conveyor means for carrying the goods to be steamed, the conveyor means traversing into the entrance of the room, through the room, and out of the exit of the room; a source of heated primary steam; first pipe means, arranged beneath the conveyor means, for jetting the heated primary steam upwardly from across the floor of the room; second pipe means disposed across the entire ceiling of the roommore » arranged above the conveyor means, for scavenging spent steam from across the entire ceiling of the room; and an ejector-condenser means, interconnected between the first pipe means, the source of primary heated steam and the second pipe means, for mixing the spent steam from the second pipe means with the heated primary steam in the first pipe means; whereby the spent steam mixed with the heated primary steam is caused to recirculate in the first pipe means through the room, thus saving energy and consuming less heated primary steam so that cost reductions will result.« less
Microwave heating apparatus and method
Johnson, Andrew J.; Petersen, Robert D.; Swanson, Stephen D.
1990-01-01
An apparatus is provided for heating and melting materials using microwave energy, and for permitting them to solidify. The apparatus includes a microwave energy source, a resonant cavity having an opening in its floor, a microwave energy choke encompassing the opening in the floor of the cavity, a metal container to hold the materials to be heated and melted, a turntable, and a lift-table. During operation, the combined action of the turntable and the lift-table position the metal container so that the top of the container is level with the floor of the cavity, is in substantial registration with the floor opening, and is encompassed by the microwave energy choke; thus, during operation, the interior of the container defines part of the resonant cavity. Additionally, a screw feeder, extending into the cavity and sheltered from microwave energy by a conveyor choke, may convey the materials to be heated to the container. Also, preferably, the floor of the resonant cavity may include perforatins, so that the offgases and dust generated in the apparatus may be removed from the resonant cavity by pulling outside air between the container choke and the exterior wall of the container into the resonant cavity and out from the cavity through the perforations.
Benchmark for Performance: Geothermal Applications in Lincoln Public Schools
DOE Office of Scientific and Technical Information (OSTI.GOV)
Durfee, D.J.; Hughes, P.J.; Martin, M.A.
1999-06-19
Vertical-bore, geothermal heat pumps (GHPs) have been providing heating and cooling to four new elementary schools located in Lincoln, Nebraska since 1995. According to representatives of the local utility and school district, the systems are providing a comfortable, complaint-free environment with utility costs that are nearly half of that of other schools in the district. Performance data collected from on-site energy management systems and district billing and utility records for all fifty schools in the Lincoln district indicate that only five consume less energy than the best performing GHP school; however these five cool less than 10% of their totalmore » floor area, while the GHP schools cool 100% of their floor area. When compared to other new schools (with similar ventilation loads), the GHP schools used approximately 26% less source energy per square foot of floor area. Variations in annual energy performance are evident among the four GHP schools, however, together they still consume less source energy than 70% of all schools in the district. These variations are most likely due to operational differences rather than installed equipment, building orientation, or environmental (bore field) conditions.« less
Benchmark for performance: Geothermal applications in Lincoln public schools
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shonder, J.A.; Martin, M.A.; Sharp, T.R.
1999-07-01
Vertical-bore, geothermal heat pumps (GHPs) have been providing heating and cooling to four new elementary schools located in Lincoln, Nebraska since 1995. According to representatives of the local utility and school district, the systems are providing a comfortable, complaint-free environment with utility costs that are nearly half of that of other schools in the district. Performance data collected from on-site energy management systems and district billing and utility records for all fifty schools in the Lincoln district indicate that only five consume less energy than the best performing GHP school; however, these five cool less than 10% of their totalmore » floor area, while the GHP schools cool 100% of their floor area. When compared to other new schools (with similar ventilation loads), the GHP schools used approximately 26% less source energy per square foot of floor area. Variations in annual energy performance are evident amongst the four GHP schools, however, together they still consume less source energy than 70% of all schools in the district. These variations are most likely due to operational differences rather than installed equipment, building orientation, or environmental (bore field) conditions.« less
ETR HEAT EXCHANGER BUILDING, TRA644. FLOOR PLAN AND SECTIONS. PUMP ...
ETR HEAT EXCHANGER BUILDING, TRA-644. FLOOR PLAN AND SECTIONS. PUMP CUBICLES WITH PUMP MOTORS OUTSIDE CUBICLES. HEAT EXCHANGER EQUIPMENT. COOLANT PIPE TUNNEL ENTERS FROM REACTOR BUILDING. KAISER ETR-5582-MTR-644-A-3, 2/1956. INL INDEX NO. 532-0644-00-486-101294, REV. 6. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
11. FIRST FLOOR BLDG. 28B: OVERVIEW SOLVENT PUMPS AND HEATING ...
11. FIRST FLOOR BLDG. 28B: OVERVIEW SOLVENT PUMPS AND HEATING LOOKING WEST. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT
Predictors of summertime heat index levels in New York City apartments
Quinn, Ashlinn; Kinney, Patrick; Shaman, Jeffrey
2018-01-01
Background During heat waves, fatal overexposure to heat most often occurs at home. It is not known how factors such as building size, floor level, and different types of air conditioning (AC) contribute to excess indoor heat. Methods We monitored indoor temperature and humidity in 36 apartments in New York City during summers 2014 and 2015, and used these values to calculate the indoor heat index (HI). We investigated the role of AC type and building-level factors on indoor HI using multilevel regression models. Results 34 of 36 homes had AC. Central and ductless AC types were associated with the coolest indoor conditions; homes with window and portable AC were significantly warmer. Apartments on the top floor of a building were significantly hotter during heat advisory periods than other apartments regardless of the presence of AC. High indoor HI levels persisted in some homes for approximately one day following the end of the two heat advisory periods. Conclusions We provide concrete evidence of higher heat levels in top floor apartments and in homes with certain types of AC. High heat levels that persist indoors after outdoor heat has subsided may present an underappreciated public health risk. PMID:28107558
Initial evaluation of floor cooling on lactating sows under severe acute heat stress
USDA-ARS?s Scientific Manuscript database
The objective was to evaluate the effects of floor cooling on lactating sows under severe summer heat stress. Twelve multiparous sows were provided with a cooling pad built with an aluminum plate surface, high-density polyethylene base and copper pipes. Treatments were randomly allotted to sows to r...
Effect of floor cooling on late lactation sows under acute heat stress
USDA-ARS?s Scientific Manuscript database
The objective was to evaluate the effects of floor cooling on late lactation sows under severe summer heat stress. Ten multiparous sows were provided with a cooling pad built with an aluminum plate surface, high-density polyethylene base and copper pipes. Treatments were randomly allotted to sows to...
Effects of floor cooling on late lactation sows under severe acute heat stress
USDA-ARS?s Scientific Manuscript database
The objective was to evaluate the effects of floor cooling on late lactation sows under severe summer heat stress. Ten multiparous sows were provided with a cooling pad built with an aluminum plate surface, high-density polyethylene base and copper pipes. Treatments were randomly allotted to sows to...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-13
... and reinforced concrete floors acting as diaphragms in distributing loads to vertically resisting... reinforced concrete foundation. The reactor is fueled with standard low-enriched TRIGA (Training, Research... cooled by a light water primary system consisting of the reactor pool and a heat removal system to remove...
Solar heating and hot water system installed at office building, One Solar Place, Dallas, Texas
NASA Technical Reports Server (NTRS)
1980-01-01
A solar heating on cooling system is described which is designed to provide 87 percent of the space heating needs, 100 percent of the potable hot water needs and is sized for future absorption cooling. The collection subsystem consists of 28 solargenics, series 76, flat plate collectors with a total area of 1,596 square feet. The solar loop circulates an ethylene glyco water solution through the collectors into a hot water system exchanger. The water storage subsystem consists of a heat exchanger, two 2,300 gallon concrete hot water storage tanks with built in heat exchangers and a back-up electric boiler. The domestic hot water subsystem sends hot water to the 10,200 square feet floor area office building hot water water fixtures. The building cold water system provides make up to the solar loop, the heating loop, and the hot water concrete storage tanks. The design, construction, cost analysis, operation and maintenance of the solar system are described.
Solar heating and cooling system installed at Leavenworth, Kansas
NASA Technical Reports Server (NTRS)
1980-01-01
A solar heating and cooling is described which is designed to furnish 90 percent of the overall heating load, 70 percent of the cooling load and 100 percent of the domestic hot water load. The building has two floors with a total of 12,000 square feet gross area. The system has 120 flat-plate liquid solar panels with a net area of 2,200 square feet. Five 3 ton Arkla solar assisted absorption units provide the cooling, in conjunction with a 3,000 gallon chilled water storage tank. Two 3,000 gallon storage tanks are provided with one designated for summer use, whereas both tanks are utilized during winter.
Predictors of summertime heat index levels in New York City apartments.
Quinn, A; Kinney, P; Shaman, J
2017-07-01
During heat waves, fatal overexposure to heat most often occurs at home. It is not known how factors such as building size, floor level, and different types of air conditioning (AC) contribute to excess indoor heat. We monitored indoor temperature and humidity in 36 apartments in New York City during summers 2014 and 2015 and used these values to calculate the indoor heat index (HI). We investigated the role of AC type and building-level factors on indoor HI using multilevel regression models. Thirty-four of 36 homes had AC. Central and ductless AC types were associated with the coolest indoor conditions; homes with window and portable AC were significantly warmer. Apartments on the top floor of a building were significantly hotter during heat advisory periods than other apartments regardless of the presence of AC. High indoor HI levels persisted in some homes for approximately 1 day following the end of the two heat advisory periods. We provide concrete evidence of higher heat levels in top floor apartments and in homes with certain types of AC. High heat levels that persist indoors after outdoor heat has subsided may present an underappreciated public health risk. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Sandblom, Erik; Clark, Timothy D; Gräns, Albin; Ekström, Andreas; Brijs, Jeroen; Sundström, L Fredrik; Odelström, Anne; Adill, Anders; Aho, Teija; Jutfelt, Fredrik
2016-05-17
Understanding the resilience of aquatic ectothermic animals to climate warming has been hindered by the absence of experimental systems experiencing warming across relevant timescales (for example, decades). Here, we examine European perch (Perca fluviatilis, L.) from the Biotest enclosure, a unique coastal ecosystem that maintains natural thermal fluctuations but has been warmed by 5-10 °C by a nuclear power plant for over three decades. We show that Biotest perch grow faster and display thermally compensated resting cardiorespiratory functions compared with reference perch living at natural temperatures in adjacent waters. However, maximum cardiorespiratory capacities and heat tolerance limits exhibit limited or no thermal compensation when compared with acutely heated reference perch. We propose that while basal energy requirements and resting cardiorespiratory functions (floors) are thermally plastic, maximum capacities and upper critical heat limits (ceilings) are much less flexible and thus will limit the adaptive capacity of fishes in a warming climate.
Design package for instrumentation of the Decade 80 house in Tucson, Arizona
NASA Technical Reports Server (NTRS)
1978-01-01
A design package covering instrumentation and system design for the Decade 80 House in Tucson, Arizona is presented. The solar house is instrumented for the purpose of gathering data to determine the solar heating and cooling system performance. The use of copper in the construction of the house is a first choice construction material because it conducts heat and resists corrosion better than other materials and therefore provides a more efficient and economical system. Equipment and site specifications are reported, along with floor plans showing the location of the site instrumentation hardware.
77 FR 43382 - Millstone Power Station, Unit 2; Exemption
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-24
... sources consisting primarily of fire retardant cable insulation and limited floor based combustibles. The... smoke detectors. The licensee stated that the smoke and heat detection systems were designed and... insulation and that potential ignition sources for these areas includes electrical faults. The licensee...
Analysis of the performance and space conditioning impacts of dedicated heat pump water heaters
NASA Astrophysics Data System (ADS)
Morrison, L.; Swisher, J.
The development and testing of the newly-marketed dedicated heat pump water heater (HPWH) are described. This system utilizes an air-to-water heat pump, costs about $1,000 installed, and obtains a coefficient of performance (COP) of about 2.0 in laboratory and field tests. To investigate HPWH performance and space conditioning impacts, a simulation was developed to mode the thermal performance of a residence with resistance baseboard heat, air conditioning, and either heat pump or resistance water heating. The building characteristics are adapted for three U.S. geographical areas (Madison, Wisconsin; Washington, D.C.; and Ft. Worth, Texas), and the system is simulated for a year with typical weather data. The thermal network includes both a house node and a basement node so that the water heating equipment can be simulated in an unconditioned basement in Northern cities and in a conditioned first-floor utility room in Southern cities.
Supersonic/Hypersonic Correlations for In-Cavity Transition and Heating Augmentation
NASA Technical Reports Server (NTRS)
Everhart, Joel L.
2011-01-01
Laminar-entry cavity heating data with a non-laminar boundary layer exit flow have been retrieved from the database developed at Mach 6 and 10 in air on large flat plate models for the Space Shuttle Return-To-Flight Program. Building on previously published fully laminar and fully turbulent analysis methods, new descriptive correlations of the in-cavity floor-averaged heating and endwall maximum heating have been developed for transitional-to-turbulent exit flow. These new local-cavity correlations provide the expected flow and geometry conditions for transition onset; they provide the incremental heating augmentation induced by transitional flow; and, they provide the transitional-to-turbulent exit cavity length. Furthermore, they provide an upper application limit for the previously developed fully-laminar heating correlations. An example is provided that demonstrates simplicity of application. Heating augmentation factors of 12 and 3 above the fully laminar values are shown to exist on the cavity floor and endwall, respectively, if the flow exits in fully tripped-to-turbulent boundary layer state. Cavity floor heating data in geometries installed on the windward surface of 0.075-scale Shuttle wind tunnel models have also been retrieved from the boundary layer transition database developed for the Return-To-Flight Program. These data were independently acquired at Mach 6 and Mach 10 in air, and at Mach 6 in CF4. The correlation parameters for the floor-averaged heating have been developed and they offer an exceptionally positive comparison to previously developed laminar-cavity heating correlations. Non-laminar increments have been extracted from the Shuttle data and they fall on the newly developed transitional in-cavity correlations, and they are bounded by the 95% correlation prediction limits. Because the ratio of specific heats changes along the re-entry trajectory, turning angle into a cavity and boundary layer flow properties may be affected, raising concerns regarding the application validity of the heating augmentation predictions.
Soil CO2 emissions as a proxy for heat and mass flow assessment, Taupō Volcanic Zone, New Zealand
Bloomberg, S.; Werner, Cynthia A.; Rissmann, C.F.; Mazot, A.; Horton, Travis B.; Gravley, D; Kennedy, B.; Oze, C
2014-01-01
The quantification of heat and mass flow between deep reservoirs and the surface is important for understanding magmatic and hydrothermal systems. Here, we use high-resolution measurement of carbon dioxide flux (φCO2) and heat flow at the surface to characterize the mass (CO2 and steam) and heat released to the atmosphere from two magma-hydrothermal systems. Our soil gas and heat flow surveys at Rotokawa and White Island in the Taupō Volcanic Zone, New Zealand, include over 3000 direct measurements of φCO2 and soil temperature and 60 carbon isotopic values on soil gases. Carbon dioxide flux was separated into background and magmatic/hydrothermal populations based on the measured values and isotopic characterization. Total CO2 emission rates (ΣCO2) of 441 ± 84 t d−1 and 124 ± 18 t d−1were calculated for Rotokawa (2.9 km2) and for the crater floor at White Island (0.3 km2), respectively. The total CO2 emissions differ from previously published values by +386 t d−1 at Rotokawa and +25 t d−1 at White Island, demonstrating that earlier research underestimated emissions by 700% (Rotokawa) and 25% (White Island). These differences suggest that soil CO2 emissions facilitate more robust estimates of the thermal energy and mass flux in geothermal systems than traditional approaches. Combining the magmatic/hydrothermal-sourced CO2 emission (constrained using stable isotopes) with reservoir H2O:CO2mass ratios and the enthalpy of evaporation, the surface expression of thermal energy release for the Rotokawa hydrothermal system (226 MWt) is 10 times greater than the White Island crater floor (22.5 MWt).
Solar space heating installed at Kansas City, Kansas
NASA Technical Reports Server (NTRS)
1981-01-01
The solar energy system was constructed with the 48,800 square feet warehouse to heat the warehouse area of about 39,000 square feet while an auxiliary energy system heats the office area of about 9,800 square feet. The building is divided into 20 equal units, and each has its own solar system. The modular design permits the flexibility of combining multiple units to form offices or warehouses of various size floor areas as required by a tenant. Each unit has 20 collectors which are mounted in a single row. The collectors are double glazed flat plate collectors with a gross area of 7,800 sq ft. Air is heated either through the collectors or by the electric resistance duct coils. Extracts from the site files, specifications, drawings, installation, operation and maintenance instructions are presented.
Solar heating and hot water system installed at Saint Louis, Missouri
NASA Technical Reports Server (NTRS)
1980-01-01
The solar heating and hot water system installed at the William Tao & Associates, Inc., office building in St. Louis, Missouri is described, including maintenance and construction problems, final drawings, system requirements, and manufacturer's component data. The solar system was designed to provide 50 percent of the hot water requirements and 45 percent of the space heating needs for a 900 sq ft office space and drafting room. The solar facility has 252 sq ft of glass tube concentrator collectors and a 1000 gallon steel storage tank buried below a concrete slab floor. Freeze protection is provided by a propylene glycol/water mixture in the collector loop. The collectors are roof mounted on a variable tilt array which is adjusted seasonally and is connected to the solar thermal storage tank by a tube-in-shell heat exchanger. Incoming city water is preheated through the solar energy thermal storage tank.
This is an ESTE project summary brief. Many of the finished interior surfaces of homes and buildings are composed of materials that are prone to mold growth. These surfaces include gypsum board, wood flooring, insulation, and components of the heating and air conditioning system...
This School Is for Kids and Community.
ERIC Educational Resources Information Center
American School Board Journal, 1982
1982-01-01
In Avon (Indiana), a community lacking public buildings, a middle school was built with community uses in mind. The swimming pool, gymnasium, and commons area can be blocked off for community use by using floor-to-ceiling gates. The school's heating, ventilating, and air conditioning systems are also energy-efficient. (Author/MLF)
Estimated Rock Abundance and Thermophysical Parameters in Oppenheimer Crater on the Moon
NASA Astrophysics Data System (ADS)
Bauch, Karin E.; Hiesinger, Harald; Ivanov, Mikhail; van der Bogert, Carolyn H.; Pasckert, Jan-Hendrik; Weinauer, Julia
2016-04-01
Oppenheimer crater is located in the north-east of the South Pole-Aitken basin (SPA), the largest impact structure on the Moon [e.g., 1]. The crater is ˜215km in diameter and has an estimated age of ˜4.1 Ga [2]. The floor of Oppenheimer shows evidence of dark mantling deposits and a concentric system of graben structures close to the rim of the crater [3]. Image and topography data show that the floor is flat apart from the graben structures and subsequent impacts on the floor. Oppenheimer-U (˜40km) and -H (˜35km) are floor-fractured craters within the north-west and south-east portions of Oppenheimer crater [3]. Dark mantling deposits on the floor are associated with the graben system. [3] estimated an age between ˜3.98Ga and ˜3.66Ga for the pyroclastic activity, based on crater size-frequency distribution (CSFD) measurements on Lunar Reconnaissance Orbiter (LRO) WAC and NAC images. In this study we compare the mapping results of [3] with temperature data of the LRO Diviner experiment [4] using a numerical model [5, 6]. Nighttime temperature variations are directly influenced by the surface and subsurface thermophysical properties, namely bulk density, heat capacity, and thermal conductivity [7, 8]. These properties can be summarized to a thermal inertia, which represents the ability to conduct and store heat [8]. Low thermal inertia units, such as dust and other fine grained material, quickly respond to temperature changes, which results in large temperature amplitudes between the lunar day and night. On the other hand, high thermal inertia material, e.g. rocks or bedrock, take more time to heat up during the day and reradiate the heat during the night [8]. Relative rock abundances are derived from temperature measurements of the same location at different wavelengths. Brightness temperatures are a function of wavelength and increase with decreasing wavelength [9, 10]. This nonlinearity of the Planck radiance can be used to determine the amount of anisothermal surfaces and, thus, the abundance of rocks within a field of view [e.g., 6, 9, 10]. The thermal maps show low temperatures, thus low thermal inertia and low rock abundances on the flat floor of Oppenheimer. Dark mantle deposits have similar thermal signatures as the floor. Higher rock abundances and thermal inertias are associated with the graben structures close to the rim of Oppenheimer and the floors of Oppenheimer-U and -H. We found that the highest values correlate with fresh craters in the northern part of Oppenheimer. High-resolution NAC images confirm the presence of boulders on the surface. References: [1] Petro, N.E., Pieters, C. M. (2004), JGR 109, E6. [2] Hiesinger, H. et al. (2012), LPSC XLIII, #2863. [3] Ivanov, M. et al. (2015), LPSC IIIX, #1070. [4] Paige, D. et al. (2010), Spac. Sci. Rev. 150, Num 1-4, p125-160. [5] Bauch, K.E. et al. (2014), PSS 101, 27-36. [6] Bauch, K.E. at al. (2013), EGU2013-8053. [7] Urquhart, M.L. and Jakosky, B.M. (1997), JGR 102, 10,959-10,969. [8] Mellon, M.T. et al. (2000), Icarus 148, 437-455. [9] Christensen, P.R. (1986), Icarus 68, 217-238. [10] Bandfield, J.L. et al. (2011), JGR 108, E12, 8086.
USDA-ARS?s Scientific Manuscript database
Listeria monocytogenes enters a poultry further processing plant with raw product and colonizes the plant as a resident in floor drains. We have shown that L. monocytogenes can escape floor drains, becoming airborne during wash down, creating potential for contamination of fully cooked product. Li...
Phase Change Energy Storage Material Suitable for Solar Heating System
NASA Astrophysics Data System (ADS)
Li, Xiaohui; Li, Haihua; Zhang, Lihui; Liu, Zhenfa
2018-01-01
Differential scanning calorimetry (DSC) was used to investigate the thermal properties of palmitic acid, myristic acid, laurel acid and the binary composite of palmitic/laurel acid and palmitic/myristic acid. The results showed that the phase transition temperatures of the three monomers were between 46.9-65.9°C, and the latent heats were above 190 J/g, which could be used as solar energy storage material. When the mass ratio of Palmitic acid and myristic was 1:1, the eutectic mixture could be formed. The latent heat of the eutectic mixture was 186.6 J/g, the melting temperature and the solidification temperature was 50.6°C and 43.8°C respectively. The latent heat of phase change and the melting temperature had not obvious variations after 400 thermal cycles, which proved that the binary composite had good thermal stability and was suitable for solar floor radiant heating system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heat transfer to slab foundations has remained an area of building science with poor understanding over the last three decades of energy efficiency research. This is somewhat surprising since the area of floors in single family homes is generally equal to wall, or windows or attics which have been extensively evaluated. Research that has been done has focused in the impact of slab on grade foundations and insulation schemes on heat losses associated with heating in predominantly heating dominated climates. Slab on grade construction is very popular in cooling-dominated southern states where it accounts for 77 percent of new homemore » floors according to U.S. Census data in 2014. There is a widespread conception that tile flooring, as opposed to carpet, makes for a cooler home interior in warm climates. Empirical research is needed as building energy simulations such as DOE-2 and EnergyPlus rely on simplified models to evaluate these influences. BA-PIRC performed experiments over an entire year from 2014-2015 in FSEC's Flexible Residential Test Facilities (FRTF) intended to assess for the first time 1) slab on grade influence in a cooling dominated climate, and 2) how the difference in a carpeted vs. uncarpeted building might influence heating and cooling. Two identical side by side residential buildings were evaluated, the East with pad and carpet and the west with a bare slab floor. A highly detailed grid of temperature measurements were taken on the slab surface at various locations as well as at depths of 1, 2.5, 5, 10 and 20 feet.« less
Evaluation of the Impact of Slab Foundation Heat Transfer on Heating and Cooling in Florida
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parker, D.; Kono, J.; Vieira, R.
During the last three decades of energy-efficiency research, there has been limited study of heat transfer to slab-on-grade foundations in cooling-dominated climates. Most experimental research has focused on the impact of slab-on-grade foundations and insulation schemes on heat losses in heating-dominated climates. This is surprising because the floor area in single-family homes is generally equal to wall area, window area, or attic area, all of which have been extensively evaluated for heat-transfer properties. Moreover, slab foundations are the most common foundation type in cooling-dominated climates. Slab-on-grade construction is very popular in southern states, accounting for 77% of new home floorsmore » according to 2014 U.S. Census data. There is a widespread perception that tile flooring, as opposed to carpet, provides a cooler home interior in warm climates. Empirical research is needed because building energy simulation software programs running DOE-2 and EnergyPlus engines often rely on simplified models to evaluate the influence of flooring on interior temperature, even though in some cases more detailed models exist. The U.S. Department of Energy Building America Partnership for Improved Residential Construction (BA-PIRC) performed experiments in the Florida Solar Energy Center’s Flexible Residential Test Facility intended to assess for the first time (1) how slab-on-grade construction influences interior cooling in a cooling-dominated climate and (2) how the difference in a carpeted versus uncarpeted building might influence heating and cooling energy use. Two nominally identical side-by-side residential buildings were evaluated during the course of 1 year, from 2014 to 2015: the east building with a pad and carpet floor and the west building with a bare slab floor. A detailed grid shows temperature measurements taken on the slab surface at various locations as well as at depths of 1.0 ft, 2 ft, 5.0 ft, 10.0 ft, and 20.0 ft below the surface. Temperature measurements were taken at both buildings for more than 3 years prior to the experiments to ensure that the ground and foundation temperatures had fully come into equilibrium.« less
NASA Astrophysics Data System (ADS)
1982-04-01
A house with approximately 1360 square feet of conditioned space heated by a direct gain system with manually operated insulated curtains is discussed. Solar heating is augmented by electric resistance heating, and a wood burning stove may be installed. Sunlight is admitted through both south facing windows and through clerestory collector panels and is absorbed and stored as heat in a concrete floor and wall. Heat is then distributed by natural convection and radiation. Temperature regulation is assisted by Earth beams. Three modes of operation are described: collector-to-storage, storage-to-space heating, and passive space cooling, which is accomplished by shading, movable insulation, and ventilation. The instrumentation for the National Solar Data Network is described. The solar energy portion of the construction costs is estimated.
NASA Astrophysics Data System (ADS)
Cavanaugh, S.; Bangs, N. L.; Hornbach, M. J.; McIntosh, K. D.
2011-12-01
We use 3D seismic reflection data acquired in April - May 2011 by the R/V Marcus G. Langseth to extract heat flow information using the bottom-simulating reflector across the Costa Rica convergent margin. These data are part of the CRISP Project, which will image the Middle America subduction zone in 3D. The survey was conducted in an area approximately 55 x 11 km, to the northwest of the Osa Peninsula, Costa Rica. For the analysis presented here, 3D seismic data were processed with Paradigm Focus software through post-stack time migration. The bottom-simulating reflector (BSR)-a reverse polarity reflection indicating the base of the gas hydrate phase boundary-is imaged very clearly in two regions within the slope-cover sediments in the accretionary prism. In deep water environments, the BSR acts as a temperature gauge revealing subsurface temperatures across the margin. We predict BSR depth using a true 3D diffusive heat flow model combined with IODP drilling data and compare results with actual BSR depth observations to determine anomalies in heat flow. Uniform heat flow in the region should result in a deepening BSR downslope toward the trench, however our initial results indicate the BSR shoals near the trench to its shallowest level below sea floor of approximately 96 m below the sea floor, suggesting elevated heat flow towards the toe. Landward, the BSR deepens to about 333 m below the sea floor indicating lower heat flow. Both BSR segments display a trend of deepening landward from the trench, however the depth below the sea floor is greater overall for the landward segment than the segment near the toe. We suggest two regimes with differing heat flow exist across the margin that likely represent two separate fluid flow regimes - one from recently accreted sediments near the prism toe and the other through the older materials making up the prism.
Terahop and Lawrence Livermore National LaboratoryStructural Fire RF Testing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haugen, P; Pratt, G
The Georgia Public Safety Training Center's Live Fire Training Facility in Forsyth, GA is a three story structure constructed of rebar-reinforced concrete wall and floors. All the door and window coverings on the building are constructed of thick, plate metal to withstand the high temperatures generated inside the building during training exercises. All of the building's walls and floors are 1-foot thick, and regular concrete columns run up along the inside of the wall increasing the thickness to 20-inches in those locations. A center concrete staircase divides the structure in half. For typical exercises, fires are started in the backmore » right corner of the building on the first floor and in the front right corner on the second floor as shown in Figure 2. Due to the high heat generated during these exercises, measured at 300 F on the floor and 700 F near the ceilings, there were limited locations at which equipment could be placed that did not incorporate heat shielding, such as the Lawrence Livermore National Laboratory's UWB system. However, upon inspection of the building, two preferable locations were identified in which equipment could be placed that would be protected from the temperature extremes generated by the fires. These locations are identified in Figure 2 as the tested TX locations. These were preferred locations because, while they protected the hardware from temperature extremes, they also force the RF transmission path through the building to cross very near the fire locations and anticipated plasma generation regions. Both of the locations listed in Figure 2 were tested by the UWB equipment and found to be suitable deployment locations to establish a solid RF link for data collection. The transmission location on the first floor was ultimately chosen for use during the actual exercises because it was accessible to the data collection team during the exercises. This allowed them to remove the hardware once the testing was complete without having to wait for the entire day of exercises to complete. Unfortunately, RF transmission directly through the central location of the fire on the first floor was not possible, so the transmission path had to be shifted approximately 6-feet off the side of the fire's center. The corner where the fire was located on the first floor was re-enforced with a mixture of concrete and metal fibers for heat resistance. This material was highly reflective, permitting very little RF energy to pass through it. This phenomenon was also observed and verified by Terahop's testing, discussed in the next section. An image of these re-enforced walls and a close up of the actual wall material containing the metal fibers can bee seen in Figure 3.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
D. Parker, E. Martin
Heat transfer to slab foundations has remained an area of building science with poor understanding over the last three decades of energy efficiency research. This is somewhat surprising since the area of floors in single family homes is generally equal to wall, or windows or attics which have been extensively evaluated. Research that has been done has focused in the impact of slab on grade foundations and insulation schemes on heat losses associated with heating in predominantly heating dominated climates. Slab on grade construction is very popular in cooling-dominated southern states where it accounts for 77 percent of new homemore » floors according to U.S. Census data in 2014. There is a widespread conception that tile flooring, as opposed to carpet, makes for a cooler home interior in warm climates. Empirical research is needed as building energy simulations such as DOE-2 and EnergyPlus rely on simplified models to evaluate these influences. BA-PIRC performed experiments over an entire year from 2014-2015 in FSEC's Flexible Residential Test Facilities (FRTF) intended to assess for the first time 1) slab on grade influence in a cooling dominated climate, and 2) how the difference in a carpeted vs. uncarpeted building might influence heating and cooling. Two identical side by side residential buildings were evaluated, the East with pad and carpet and the west with a bare slab floor. A highly detailed grid of temperature measurements were taken on the slab surface at various locations as well as at depths of 1, 2.5, 5, 10 and 20 feet.« less
NASA Astrophysics Data System (ADS)
Doering, E.; Lippe, W.
1982-08-01
The technical and economic performances of a complementary solar heating installation for a new swimming pool added to a two-floor dwelling were examined after measurements were taken over a period of 12 months and analyzed. In particular, the heat absorption and utilization were measured and modifications were carried out to improve pipe insulation and regulation of mixer valve motor running and volume flow. The collector system efficiency was evaluated at 15.4%, the proportion of solar energy of the total consumption being 6.1%. The solar plant and the measuring instruments are described and recommendations are made for improved design and performance, including enlargement of the collector surface area, further modification of the regulation system, utilization of temperature stratification in the storage tanks and avoiding mutual overshadowing of the collectors.
NASA Astrophysics Data System (ADS)
Nemethova, Ema; Stutterecker, Werner; Schoberer, Thomas
2017-06-01
The aim of the study is to evaluate the potential of enhancing thermal comfort and energy consumption created by three different radiant systems in the newly-built Energetikum office building. A representative office, Simulation room 1/1, was selected from 6 areas equipped with portable sensor groups for the indoor environment monitoring. The presented data obtained from 3 reference weeks; the heating, transition and cooling periods indicate overheating, particularly during the heating and transition period. The values of the indoor air temperature during the heating and transition period could not meet the normative criteria according to standard EN 15251:2007 (cat. II.) for 15-30% of the time intervals evaluated. Consequently, a simulation model of the selected office was created and points to the possibilities of improving the control system, which can lead to an elimination of the problem with overheating. Three different radiant systems - floor heating/ cooling, a thermally active ceiling, and a near-surface thermally active ceiling were implemented in the model. A comparison of their effects on thermal comfort and energy consumption is presented in the paper.
Grid-connected integrated community energy system. Volume II. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1977-07-01
A preliminary feasibility analysis of a grid-connected ICES in the City of Independence, Missouri, is presented. It is found that the ICES concept can be made feasible in Independence by employing a 20-MW coal-fired boiler and turbine and using waste heat to provide the energy for heating and cooling commercial facilities with over 3 million square feet of floor space. When fully loaded thermally, the ICES results in favorable fuel utilization and energy conservation in comparison to conventional energy systems. The City of Independence is experienced with all of the institutional factors that may impact the ICES Demonstration Project.
DOE Zero Energy Ready Home Case Study: Amaris Homes, Afton Model
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pacific Northwest National Laboratory
Amaris Homes built this 3,734-ft2 home in Afton, Minnesota, to the performance criteria of the DOE Zero Energy Ready Home (ZERH) program. A high-efficiency gas boiler provides hot water for the zoned radiant floor system as well as for faucets and showers. A high-efficiency heat pump provides zoned cooling.
NASA Astrophysics Data System (ADS)
Krarouch, M.; Hamdi, H.; Lamghari, S.; Outzourhit, A.
2018-05-01
This study was conducted in the framework of the HYBRID-BATH project aiming at improving the energy efficiency of traditional Hammams (Turkish baths) and the reduction of the use of wood energy and therefore of greenhouse gases emissions. The present work focuses on the energetic performance of a two-room Hammam located in Marrakech. The rooms were heated by the ground using a hybrid system Micro-CSP/biomass boiler. The dynamic simulation of the system (Hammam coupled with the hybrid system Micro-CSP/biomass boiler) was conducted using TRNSYS18 software. The parametric study was performed on a Typical Meteorological Year data (TMY). This study is devoted to presenting the results of the dynamic simulation of a part of the Hammam investigated, in order to optimize the underfloor heating system. The models and the results of the simulations will be validated by comparisons with experimental results. The main objective is to optimize the operation of such system and to improve its performance.
2011-01-01
Window film should be considered to control heat gain. Skylights when positioned and spaced properly with the proper lens systems, admit more light...per unit area than windows, and distribute the light more evenly over the space. Skylights are mainly recommended in single floor high bay...facilities such as warehouses, hangars, gymnasiums, and big box stores. The optimum material to use for skylights is either glass or acrylic. Double
Effects of Crack on Heat Flux in Hypersonic Shock/Boundary-Layer Interaction
NASA Astrophysics Data System (ADS)
Ozawa, Hiroshi; Hanai, Katsuhisa; Kitamura, Keiichi; Mori, Koichi; Nakamura, Yoshiaki
A small crack on body surface led to a tragic accident in 2003, which is the Columbia accident. During the shuttle's re-entry, high temperature gas penetrated crack on leading-edge of the left wing and melted the aluminum structure, finally the Columbia blew up. Since early times, there are many fundamental studies about simple cavity-flow formed on body surface in hypersonic speeds. However, an investigation of Shock/Boundary-Layer Interaction (SBLI) on crack has not been researched. For multistage space transportation vehicle such as TSTO, SBLI is an inevitable problem, and then SBLI on crack becomes a critical issue for TSTO development. In this study, the effects of crack, where SBLI occurs, were investigated for TSTO hypersonic speed (M∞ = 8.1). A square crack locates at SBLI point on the TSTO booster. Results show that a crack and its depth strongly effect on peak heat flux and aerodynamic interaction flow-field. In the cases of shallow crack (d/C ≤ 0.10), there exist two high heat flux regions on crack floor, which locates at a flow reattachment region and a back end wall of crack. In this case, a peak heat flux at flow reattachment region becomes about 2 times as large as the stagnation point heat flux, which value becomes larger compared with a peak heat flux in the case of No-Crack TSTO. While in the case of deep crack (d/C = 0.20), overall heat flux on crack floor decreases to below the stagnation point heat flux. These results provide useful data for a development of TSTO thermal protection system (TPS) such as thermal protection tile.
12. SW corner of 2nd floor of Tender Frame Shop ...
12. SW corner of 2nd floor of Tender Frame Shop showing heating duct and diffuser. - Central of Georgia Railway, Savannah Repair Shops & Terminal Facilities, Tender Frame Shop, Bounded by West Broad, Jones, West Boundary & Hull Streets, Savannah, Chatham County, GA
Exterior Insulation Implications for Heating and Cooling Systems in Cold Climates
DOE Office of Scientific and Technical Information (OSTI.GOV)
Herk, Anastasia; Poerschke, Andrew
The New York State Energy Research and Development Authority (NYSERDA) is interested in finding cost-effective solutions for deep energy retrofits (DERs) related to exterior wall insulation in a cold climate, with targets of 50% peak load reduction and 50% space conditioning energy savings. The U.S. Department of Energy Building America team, IBACOS, in collaboration with GreenHomes America, Inc. (GHA), was contracted by NYSERDA to research exterior wall insulation solutions. In addition to exterior wall insulation, the strategies included energy upgrades where needed in the attic, mechanical and ventilation systems, basement, band joist, walls, and floors. Under Building America, IBACOS ismore » studying the impact of a “thermal enclosure” DER on the sizing of the space conditioning system and the occupant comfort if the thermal capacity of the heating and cooling system is dramatically downsized without any change in the existing heating and cooling distribution system (e.g., size, tightness and supply outlet configurations).« less
Solar energy for a community recreation center
DOE Office of Scientific and Technical Information (OSTI.GOV)
Libman, D.E.
1980-01-01
A 58,000 ft/sup 2/ recreation center in Shenandoah, Georgia is described. Rooftop solar collectors and reflectors serve as a basis for the active solar heating and cooling systems. The recreation center clearly demonstrates the technical feasibility of solar application in a recreation setting; economically, however, results are shown to be mixed. Although effective in the heating mode, solar cooling is considered as questionable in terms of a reasonable payoff period. A computer model predicts a payoff period of 11 years based on 1977 energy prices. The design and construction costs of the solar heating and cooling system ($726,000) was 90%more » financed by ERDA. A hockey-size ice rink and a gymnasium plus locker rooms and meeting rooms comprised the major part of the floor space. Problems encountered and operation of the facility are described. (MJJ)« less
Earth tides, global heat flow, and tectonics
Shaw, H.R.
1970-01-01
The power of a heat engine ignited by tidal energy can account for geologically reasonable rates of average magma production and sea floor spreading. These rates control similarity of heat flux over continents and oceans because of an inverse relationship between respective depth intervals for mass transfer and consequent distributions of radiogenic heat production.
Solar energy system performance evaluation: Seasonal report for IBM system 1A, Huntsville, Alabama
NASA Technical Reports Server (NTRS)
1980-01-01
The operational and thermal performance of the solar energy system, Sims Prototype System 1A, is described. The system was designed by IBM to provide 50 to 60 percent of the space heating and domestic hot water preheating load to a 2,000 square foot floor space single family residence in the Huntsville area. The load design temperature inside the building was to be maintained at 70 degrees fahrenheit with auxiliary energy for heating supplied by an electric heat pump assisted by an electric resistance strip heater. In general the disappointing operation of this system is attributed to the manner in which it was used. The system was designed for residential application and used to satisfy the demands of an office environment. The differences were: (1) inside temperature was not maintained at 70 F as expected; and (2) hot water usage was much lower than expected. The conclusion is that the solar energy system must be designed for the type of application in which it is used. Misapplication usually will have an adverse affect on system performance.
Code of Federal Regulations, 2013 CFR
2013-04-01
... temperature in such quarters falls below 68°. (b) Any stoves or other sources of heat utilizing combustible... concrete slab, insulated metal sheet, or other fireproof material on the floor under each stove, extending...
Code of Federal Regulations, 2010 CFR
2010-04-01
... temperature in such quarters falls below 68°. (b) Any stoves or other sources of heat utilizing combustible... concrete slab, insulated metal sheet, or other fireproof material on the floor under each stove, extending...
Code of Federal Regulations, 2011 CFR
2011-04-01
... temperature in such quarters falls below 68°. (b) Any stoves or other sources of heat utilizing combustible... concrete slab, insulated metal sheet, or other fireproof material on the floor under each stove, extending...
Code of Federal Regulations, 2012 CFR
2012-04-01
... temperature in such quarters falls below 68°. (b) Any stoves or other sources of heat utilizing combustible... concrete slab, insulated metal sheet, or other fireproof material on the floor under each stove, extending...
Code of Federal Regulations, 2014 CFR
2014-04-01
... temperature in such quarters falls below 68°. (b) Any stoves or other sources of heat utilizing combustible... concrete slab, insulated metal sheet, or other fireproof material on the floor under each stove, extending...
Assembly room, bunkhouse first floor interior. Vent pipe for missing ...
Assembly room, bunkhouse first floor interior. Vent pipe for missing heating stove exited through opening into chimney, seen on the far wall. Walls are exposed studs and bracing with board and battan on the exterior and interior sides. - Sespe Ranch, Bunkhouse, 2896 Telegraph Road, Fillmore, Ventura County, CA
INTERIOR OF BUILDING 2, TYPICAL OFFICE (#212) WINDOW AND HEAT ...
INTERIOR OF BUILDING 2, TYPICAL OFFICE (#212) WINDOW AND HEAT REGISTER, SECOND FLOOR. FACING SOUTH - Roosevelt Base, Dispensary, Corner of Colorado Street & Richardson Avenue, Long Beach, Los Angeles County, CA
Converting Residential Drawing Courses to Metric.
ERIC Educational Resources Information Center
Goetsch, David L.
1980-01-01
Describes the process of metric conversion in residential drafting courses. Areas of concern are metric paper sizes; metric scale; plot, foundation, floor and electric plans; wall sections; elevations; and heat loss/ heat gain calculations. (SK)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parker, D.; Kono, J.; Vieira, R.
During the last three decades of energy-efficiency research, there has been limited study of heat transfer to slab-on-grade foundations in cooling-dominated climates. Most experimental research has focused on the impact of slab-on-grade foundations and insulation schemes on heat losses in heating-dominated climates. This is surprising because the floor area in single-family homes is generally equal to wall area, window area, or attic area, all of which have been extensively evaluated for heat-transfer properties. Moreover, slab foundations are the most common foundation type in cooling-dominated climates. Slab-on-grade construction is very popular in southern states, accounting for 77% of new home floorsmore » according to 2014 U.S. Census data. There is a widespread perception that tile flooring, as opposed to carpet, provides a cooler home interior in warm climates. Empirical research is needed because building energy simulation software programs running DOE-2 and EnergyPlus engines often rely on simplified models to evaluate the influence of flooring on interior temperature, even though in some cases more detailed models exist. The U.S. Department of Energy Building America Partnership for Improved Residential Construction (BA-PIRC) performed experiments in the Florida Solar Energy Center’s Flexible Residential Test Facility intended to assess for the first time (1) how slab-on-grade construction influences interior cooling in a cooling-dominated climate and (2) how the difference in a carpeted versus uncarpeted building might influence heating and cooling energy use. Two nominally identical side-by-side residential buildings were evaluated during the course of 1 year, from 2014 to 2015: the east building with a pad and carpet floor and the west building with a bare slab floor. A detailed grid shows temperature measurements taken on the slab surface at various locations as well as at depths of 1.0 ft, 2 ft, 5.0 ft, 10.0 ft, and 20.0 ft below the surface. Temperature measurements were taken at both buildings for more than 3 years prior to the experiments to ensure that the ground and foundation temperatures had fully come into equilibrium.« less
DOT National Transportation Integrated Search
2018-01-01
This project was initiated by the ODOT District 2 staff who were looking for more efficient ways to heat and operate their maintenance facilities. This especially applied to the idea of using radiant floor heating as an alternative to todays stand...
Oh, Hyeon-Ju; Jeong, Na-Na; Chi, Woo-Bae; Seo, Ji-Hoon; Jun, Si-Moon; Sohn, Jong-Ryeul
2015-10-01
Particulate matter (PM) in buildings are mostly sourced from the transport of outdoor particles through a heating, ventilation, and air conditioning (HVAC) system and generation of particle within the building itself. We investigated the concentrations and characteristic of indoor and outdoor particles and airborne bacteria concentrations across four floors of a building located in a high-traffic area. In all the floors we studied (first, second, fifth, and eighth), the average concentrations of particles less than 10 μm (PM10) in winter for were higher than those in summer. On average, a seasonal variation in the PM10 level was found for the first, fifth, and eighth floors, such that higher values occurred in the winter season, compared to the summer season. In addition, in winter, the indoor concentrations of PM10 on the first, fifth, and eighth floors were higher than those of the outdoor PM10. The maximum level of airborne bacteria concentration was found in a fifth floor office, which held a private academy school consisting of many students. Results indicated that the airborne bacteria remained at their highest concentration throughout the weekday period and varied by students' activity. The correlation coefficient (R (2)) and slope of linear approximation for the concentrations of particulate matter were used to evaluate the relationship between the indoor and outdoor particulate matter. These results can be used to predict both the indoor particle levels and the risk of personal exposure to airborne bacteria.
Design and fabrication of metal briquette machine for shop floor
NASA Astrophysics Data System (ADS)
Pramod, R.; Kumar, G. B. Veeresh; Prashanth B., N.
2017-07-01
Efforts have to be taken to ensure efficient waste management system in shop floors, with minimum utilization of space and energy when it comes to disposing metal chips formed during machining processes. The salvaging of junk metallic chips and the us e of scrap are important for the economic production of a steelworks. For this purpose, we have fabricated a metal chip compaction machine, which can compact the metal chips into small briquettes. The project started with the survey of chips formed in shop floors and the practices involved in waste management. Study was done on the requirements for a better compaction. The heating chamber was designed taking into consideration the temperature required for an easy compaction of the metal chips. The power source for compaction and the pneumatic design for mechanism was done following the appropriate calculations regarding the air pressure provided and thrust required. The processes were tested under different conditions and found effective. The fabrication of the machine has been explained in detail and the results have been discussed.
A Web-Based Simulation Tool on The Performance of Different Roofing Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Joe; New, Joshua Ryan; Miller, William A
The Roof Savings Calculator (www.roofcalc.com) provides the general public with a web-based program for calculating the energy savings of different roofing and attic systems on four different building types (residential, office, retail, and warehouse) in 239 US TMY2 locations. The core simulation engine of the RSC is doe2attic, which couples the AtticSim program developed by Oak Ridge National Laboratory with the DOE-2.1E program originally developed by Lawrence Berkeley National Laboratory a widely used whole-building simulation program since the 1980 s. Although simulating heat flows through the roof may seem to be an easy task, simulating the net effect of roofingmore » strategies on building heating and cooling energy use can be quite challenging. Few simulation programs can reliably capture dynamics including an attic or plenum with large day-night temperature swings, high ventilation rates, significant radiant exchange between the roof and the attic floor and thermal interactions when there are ducts in the attic, as is typical in North American buildings. The doe2attic program has been tested against detailed measurements gathered in two residential buildings in Fresno, California from cooling energy use to air and surface temperatures, and heat fluxes of the roof and attic floor. The focus of this paper is on the doe2attic simulation tool, but the user interface of the RSC will also be briefly described.« less
Real-time modeling of heat distributions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hamann, Hendrik F.; Li, Hongfei; Yarlanki, Srinivas
Techniques for real-time modeling temperature distributions based on streaming sensor data are provided. In one aspect, a method for creating a three-dimensional temperature distribution model for a room having a floor and a ceiling is provided. The method includes the following steps. A ceiling temperature distribution in the room is determined. A floor temperature distribution in the room is determined. An interpolation between the ceiling temperature distribution and the floor temperature distribution is used to obtain the three-dimensional temperature distribution model for the room.
Hydronic Heating Coil Versus Propane Furnace, Rehoboth Beach, Delaware (Fact Sheet)
DOE Office of Scientific and Technical Information (OSTI.GOV)
None, None
2014-01-01
Insight Homes constructed two houses in Rehoboth Beach, Delaware, with identical floor plans and thermal envelopes but different heating and domestic hot water (DHW) systems. Each house is 1,715-ft 2 with a single story, three bedrooms, two bathrooms, and the heating, ventilation, and air conditioning (HVAC) systems and ductwork located in conditioned crawlspaces. The standard house, which the builder offers as its standard production house, uses an air source heat pump (ASHP) with supplemental propane furnace heating. The Building America test house uses the same ASHP unit with supplemental heat provided by the DHW heater (a combined DHW and hydronicmore » heating system, where the hydronic heating element is in the air handler). Both houses were occupied during the test period. Results indicate that efficiency of the two heating systems was not significantly different. Three issues dominate these results; lower system design performance resulting from the indoor refrigerant coil selected for the standard house, an incorrectly functioning defrost cycle in the standard house, and the low resolution of the natural gas monitoring equipment. The thermal comfort of both houses fell outside the ASHRAE Standard 55 heating range but was within the ACCA room-to-room temperature range when compared to the thermostat temperature. The monitored DHW draw schedules were input into EnergyPlus to evaluate the efficiency of the tankless hot water heater model using the two monitored profiles and the Building America House Simulation Protocols. The results indicate that the simulation is not significantly impacted by the draw profiles.« less
Energy Conservation: Heating Navy Hangars
1984-07-01
temperature, IF Tf Inside air temperature 1 foot above the floor, OF T. Inside design temperature, IF To Hot water temperature setpoint , OF TON Chiller ...systems capable of optimizing energy usage base-wide. An add-on to an existing large scale EMCS is probably the first preference, followed by single...the building comfort conditions are met during hours of building occupancy. 2. Optimized Start/Stop turns on equipment at the latest possible time and
USDA-ARS?s Scientific Manuscript database
Listeria monocytogenes can colonize a poultry processing or further processing plant as a resident in floor drains. Limiting growth and attachment to drain surfaces may help lessen the potential for cross contamination of product. The objective of this study was to compare a synthetic hydrogen per...
MTR WING, TRA604. BASEMENT FLOOR PLAN. FIREPROOF RECORD ROOM BELOW ...
MTR WING, TRA-604. BASEMENT FLOOR PLAN. FIRE-PROOF RECORD ROOM BELOW COUNTING ROOM. HEATING AND COOLING EQUIPMENT. UNSPECIFIED EXPANSION AREA ALONG WEST WALL. BLAW-KNOX 3150-4-1, 7/1950. INL INDEX NO. 531-0604-00-098-100007, REV. 1. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Berrang, Mark E; Hofacre, Charles L; Frank, Joseph F
2014-12-01
Listeria monocytogenes can colonize a poultry processing plant as a resident in floor drains. Limiting growth and attachment to drain surfaces may help lessen the potential for cross-contamination of product. The objective of this study was to compare a hydrogen peroxide-peroxyacetic acid-based chemical to chitosan-arginine or heat to prevent attachment of or destroy existing L. monocytogenes on the inner surface of model floor drains. L. monocytogenes was introduced to result in about 10(9) planktonic and attached cells within untreated polyvinyl chloride model drain pipes. Treatments (0.13 % peroxide-based sanitizer, 0.1 % chitosan-arginine, or 15 s of hot water at 95 to 100°C) were applied immediately after inoculation or after 24 h of incubation. Following treatment, all pipes were incubated for an additional 24 h; planktonic and attached cells were enumerated by plate count. All treatments significantly (P < 0.05) lowered numbers of planktonic and attached cells recovered. Chitosan-arginine resulted in approximately a 6-log reduction in planktonic cells when applied prior to incubation and a 3-log reduction after the inoculum had a chance to grow. Both heat and peroxide significantly outperformed chitosan-arginine (8- to 9-log reduction) and were equally effective before and after incubation. Heat was the only treatment that eliminated planktonic L. monocytogenes. All treatments were less effective against attached cells. Chitosan-arginine provided about a 4.5-log decrease in attached cells when applied before incubation and no significant decrease when applied after growth. Like with planktonic cells, peroxide-peroxyacetic acid and heat were equally effective before or after incubation, causing decreases ranging from 7 to 8.5 log for attached L. monocytogenes. Applied at the most efficacious time, any of these techniques may lessen the potential for L. monocytogenes to remain as a long-term resident in processing plant floor drains.
Air-to-Water Heat Pumps With Radiant Delivery in Low-Load Homes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Backman, C.; German, A.; Dakin, B.
2013-12-01
Space conditioning represents nearly 50% of average residential household energy consumption, highlighting the need to identify alternative cost-effective, energy-efficient cooling and heating strategies. As homes are better built, there is an increasing need for strategies that are particularly well suited for high performance, low load homes. ARBI researchers worked with two test homes in hot-dry climates to evaluate the in-situ performance of air-to-water heat pump (AWHP) systems, an energy efficient space conditioning solution designed to cost-effectively provide comfort in homes with efficient, safe, and durable operation. Two monitoring projects of test houses in hot-dry climates were initiated in 2010 tomore » test this system. Both systems were fully instrumented and have been monitored over one year to capture complete performance data over the cooling and heating seasons. Results are used to quantify energy savings, cost-effectiveness, and system performance using different operating modes and strategies. A calibrated TRNSYS model was developed and used to evaluate performance in various climate regions. This strategy is most effective in tight, insulated homes with high levels of thermal mass (i.e. exposed slab floors).« less
Nondestructive structural evaluation of wood floor systems with a vibration technique.
Xiping Wang; Robert J. Ross; Lawrence Andrew Soltis
2002-01-01
The objective of this study was to determine if transverse vibration methods could be used to effectively assess the structural integrity of wood floors as component systems. A total of 10 wood floor systems, including 3 laboratory-built floor sections and 7 in-place floors in historic buildings, were tested. A forced vibration method was applied to the floor systems...
Evaluation of floor cooling on lactating sows under mild and moderate heat stress
USDA-ARS?s Scientific Manuscript database
The effectiveness of sow cooling pads during lactation was evaluated under mild and moderate heat stress conditions. The moderate heat stress room was targeted to achieve 32°C from 0800 to 1600 h and 27°C for the rest of the day. The mild heat stress room was targeted to achieve 27°C and 22°C for th...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Herk, Anastasia; Poerschke, Andrew
The New York State Energy Research and Development Authority (NYSERDA) is interested in finding cost-effective solutions for deep energy retrofits (DERs) related to exterior wall insulation in a cold climate, with targets of 50% peak load reduction and 50% space conditioning energy savings. The U.S. Department of Energy Building America team, IBACOS, in collaboration with GreenHomes America, Inc. (GHA), was contracted by NYSERDA to research exterior wall insulation solutions. In addition to exterior wall insulation, the strategies included energy upgrades where needed in the attic, mechanical and ventilation systems, basement, band joist, walls, and floors. Under Building America, IBACOS ismore » studying the impact of a “thermal enclosure” DER on the sizing of the space conditioning system and the occupant comfort if the thermal capacity of the heating and cooling system is dramatically downsized without any change in the existing heating and cooling distribution system (e.g., size, tightness and supply outlet configurations).« less
Solar energy system performance evaluaton: Seasonal report for Solaron-Akron, Akron, Ohio
NASA Technical Reports Server (NTRS)
1980-01-01
The operational and thermal performance of the solar energy system by Solaron Corporation is described. The system was designed to provide an 1940 square foot floor area with space heating and domestic hot water for a dual-level single family residence in Akron, Ohio. The solar energy system uses air as the heat transport medium, has a 546 square foot flat plate collector array subsystem, a 270 cubic foot rock thermal storage bin subsystem, a domestic hot water preheat tank, pumps, controls and transport lines. In general, the performance of the Solaron Akron solar energy system was somewhat difficult to assess for the November 1978 through October 1979 time period. The problems relating to the control systems, various solar energy leakages, air flow correction factors and instrumentation cause a significant amount of subjectivity to be involved in the performance assessment for this solar energy system. Had these problems not been present, it is felt that this system would have exhibited a resonably high level of measured performance.
NASA Technical Reports Server (NTRS)
1997-01-01
Under a Space Act Agreement between Boeing North America and BSR Products, Space Shuttle Thermal Protection System (TPS) materials are now used to insulate race cars. BSR has created special TPS blanket insulation kits for use on autos that take part in NASCAR events, and other race cars through its nationwide catalog distribution system. Temperatures inside a race car's cockpit can soar to a sweltering 140 to 160 degrees, with the extreme heat coming through the engine firewall, transmission tunnel, and floor. It is common for NASCAR drivers to endure blisters and burns due to the excessive heat. Tests on a car insulated with the TPS material showed a temperature drop of some 50 degrees in the driver's cockpit. BSR-TPS Products, Inc. now manufactures insulation kits for distribution to race car teams around the world.
Natural convection flows and associated heat transfer processes in room fires
NASA Astrophysics Data System (ADS)
Sargent, William Stapf
This report presents the results of experimental investigations of natural convection flows and associated heat transfer processes produced by small fires in rooms with a single door or window opening. Calculation procedures have been developed to model the major aspects of these flows.Two distinct sets of experiments were undertaken.First, in a roughly 1/4 scale facility, a slightly dense solution of brine was allowed to flow into a tank of fresh water. The resulting density difference produced a flow which simulated a very small fire in a room with adiabatic walls. Second, in an approximately 1/2 scale test room, a nearly stoichioinetric mixture of air and natural gas was burned at floor level to model moderate strength fires. In this latter facility, we directly measured the heat conducted through the walls, in addition to determining the gas temperature and composition throughout the room.These two facilities complemented each other. The former offered good flow visualization and allowed us to observe the basic flow phenomena in the absence of heat transfer effects. On the other hand, the latter, which involved relatively larger fires, was a more realistic simulation of an actual room fire, and allowed us to calculate the convective heat transfer to the ceiling and walls. In addition, the stronger sources present in these 1/2 scale tests produced significant secondary flows. These secondary flows along with heat transfer effects act to modify the gas temperature or density profiles within the room from those observed in the 1/4 scale experiments.Several calculation procedures have been developed, based on the far field properties of plumes when the density differences are small (the Boussinesq approximation). The simple point source plume solution is used along with hydraulic analysis of flow through an orifice to estimate the temperatures of the hot ceiling layer gas and of the cooler floor zone fluid, as well as the height of the interface between them. A finite source plume model is combined with conservation equations across the interface to compute the evolution of the plume above the interface. This calculation then provides the starting point for an integral analysis of the flow and heat transfer in the turbulent ceiling jet.The computed results both for the average floor and ceiling zone gas temperatures, and for the connective heat transfer in the ceiling jet agreed reasonably well with our experimental data. This agreement suggests that our computational procedures can be applied to answer practical questions, such as whether the connective heat flux from a given fire in a real room would be sufficient to trigger sprinklers or other detection systems in a given amount of time.
NASA Astrophysics Data System (ADS)
Jiang, D.; Xiao, W.; Wang, J.; Wang, H.; Zhao, Y.; Wang, Y.
2017-12-01
The heating energy consumption per floor area (HECPA) and heating degree days (HDD) are effective indicators in quantifying the energy demand for heating with climate change. Using the heating energy consumption and meteorological data, an attempt has been made to analyse the relationship between the HECPA and HDD in different regions of northern China by the linear regression model. Based on the constructed model, the effects of one cold wave on heating energy consumption in different regions are evaluated. The results show that the HECPA and HDD in Beijing have a positive correlation with a correlation coefficient of 0.68. During the cold wave in 2016, the heating energy consumption in Beijing approximately increases 2.37 per cent compared with 2014. However, no correlation has been found between the HECPA and HDD in the relatively undeveloped regions. It seems that the cold wave has a greater effect on the developed regions than relatively undeveloped ones. It is considered that the reasons for the little effect of one cold wave on heating energy consumption in the undeveloped regions are outdated heating systems, insufficient energy supply for heating and low living standards.
7 CFR 1436.6 - Eligible storage or handling equipment.
Code of Federal Regulations, 2012 CFR
2012-01-01
... eligible facility loan commodity, such as cleaners, moisture testers, and heat detectors; (4) Electrical... moisture testers, and heat detectors; (vii) Electrical equipment, including labor and materials for..., but are not limited to, the following: An insulated cement slab floor, insulation for walls and...
7 CFR 1436.6 - Eligible storage or handling equipment.
Code of Federal Regulations, 2010 CFR
2010-01-01
... stored eligible facility loan commodity, such as cleaners, moisture testers, and heat detectors; (4... moisture testers, and heat detectors; (vii) Electrical equipment, including labor and materials for..., but are not limited to, the following: An insulated cement slab floor, insulation for walls and...
7 CFR 1436.6 - Eligible storage or handling equipment.
Code of Federal Regulations, 2014 CFR
2014-01-01
... eligible facility loan commodity, such as cleaners, moisture testers, and heat detectors; (4) Electrical... moisture testers, and heat detectors; (vii) Electrical equipment, including labor and materials for..., but are not limited to, the following: An insulated cement slab floor, insulation for walls and...
7 CFR 1436.6 - Eligible storage or handling equipment.
Code of Federal Regulations, 2011 CFR
2011-01-01
... stored eligible facility loan commodity, such as cleaners, moisture testers, and heat detectors; (4... moisture testers, and heat detectors; (vii) Electrical equipment, including labor and materials for..., but are not limited to, the following: An insulated cement slab floor, insulation for walls and...
7 CFR 1436.6 - Eligible storage or handling equipment.
Code of Federal Regulations, 2013 CFR
2013-01-01
... eligible facility loan commodity, such as cleaners, moisture testers, and heat detectors; (4) Electrical... moisture testers, and heat detectors; (vii) Electrical equipment, including labor and materials for..., but are not limited to, the following: An insulated cement slab floor, insulation for walls and...
Oceanic lithosphere and asthenosphere: The thermal and mechanical structure
NASA Technical Reports Server (NTRS)
Schubert, G.; Froidevaux, C.; Yuen, D. A.
1976-01-01
A coupled thermal and mechanical solid state model of the oceanic lithosphere and asthenosphere is presented. The model includes vertical conduction of heat with a temperature dependent thermal conductivity, horizontal and vertical advection of heat, viscous dissipation or shear heating, and linear or nonlinear deformation mechanisms with temperature and pressure dependent constitutive relations between shear stress and strain rate. A constant horizontal velocity u sub 0 and temperature t sub 0 at the surface and zero horizontal velocity and constant temperature t sub infinity at great depth are required. In addition to numerical values of the thermal and mechanical properties of the medium, only the values of u sub 0, t sub 0 and t sub infinity are specified. The model determines the depth and age dependent temperature horizontal and vertical velocity, and viscosity structures of the lithosphere and asthenosphere. In particular, ocean floor topography, oceanic heat flow, and lithosphere thickness are deduced as functions of the age of the ocean floor.
van Krimpen, M M; Binnendijk, G P; van den Anker, I; Heetkamp, M J W; Kwakkel, R P; van den Brand, H
2014-11-01
Environmental factors, such as ambient temperature (T), feather cover (FC), and housing system (HS), probably affect energy requirements of laying hens. Using a 3 × 2 × 2 factorial arrangement, interaction effects of T (11, 16, and 21°C), FC (100 and 50%), and HS (cage and floor housing) on energy partitioning and performance of laying hens were investigated. Six batches of 70 H&N Brown Nick laying hens, divided over 2 respiration chambers, were exposed to the T levels in three 2-wk periods. Heat production (HP) was determined by indirect calorimetry. The ME intake was calculated by subtracting energy in manure/litter from that in feed and wood shavings. The NE was calculated by subtracting HP from ME. The ME intake increased by 1% for each degree reduction in T. In hens with intact plumage, HP was not affected by T, whereas at decreasing T, HP increased in hens with 50% FC (P < 0.01). At 21°C, HP was not affected by HS, whereas in the floor system, HP at 16 and 11°C was 5.8 and 3.0% higher, respectively, than in cages (P < 0.05). The NE for production was 25.7% higher in cages compared to the floor system (P < 0.05). In cages, 24.7% of NE for production was spent on body fat deposition, whereas in the floor system, 9.0% of NE for production was released from body fat reserves. The ME intake was predicted by the equation (R(2) = 0.74) ME intake (kJ/d) = 612 BW(0.75) - (8.54 × T) + (28.36 × ADG) + (10.43 × egg mass) - (0.972 × FC). Hen performances were not affected by treatments, indicating the adaptive capacity of young laying hens to a broad range of environmental conditions.
Fission product transport analysis in a loss of decay heat removal accident at Browns Ferry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wichner, R.P.; Weber, C.F.; Hodge, S.A.
1984-01-01
This paper summarizes an analysis of the movement of noble gases, iodine, and cesium fission products within the Mark-I containment BWR reactor system represented by Browns Ferry Unit 1 during a postulated accident sequence initiated by a loss of decay heat removal (DHR) capability following a scram. The event analysis showed that this accident could be brought under control by various means, but the sequence with no operator action ultimately leads to containment (drywell) failure followed by loss of water from the reactor vessel, core degradation due to overheating, and reactor vessel failure with attendant movement of core debris ontomore » the drywell floor.« less
ERIC Educational Resources Information Center
Franzen, Mark; Gorrell, Kyle
2002-01-01
Based on one school district's experience, discusses raised access flooring systems for schools. Addresses the nuts and bolts of such flooring systems, integrating an air delivery system below the flooring, advantages of floor-level air supply, and design issues. (EV)
Case Study for the ARRA-funded GSHP Demonstration at Furman University
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Xiaobing; Malhotra, Mini
With funding provided by the American Recovery and Reinvestment Act, 26 ground source heat pump (GSHP) projects were competitively selected in 2009 to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. One of the selected demonstration projects was proposed by Furman University for ten student housing buildings—the North Village located on the campus in Greeneville, South Carolina. All ten buildings are identical in floor plan and construction. Each building is conditioned by an identical GSHP system consisting of 25 water-to-air heat pump (WAHP) units, a closed-loop vertical ground heat exchanger (GHX) installed undermore » an adjacent parking lot, and two redundant 7.5 hp variable-speed pumps to circulate water through the GHX and the WAHPs. The actual performance of the GSHP systems is analyzed with available measured data for 2014. The annual energy performance is compared with a baseline scenario in which the building is conditioned by air-source heat pumps (ASHPs) with the minimum allowed efficiencies specified in ASHRAE Standard 90.1-2013 (SEER 13 for cooling and 7.8 HSPF for heating) and supplemental electric heaters. The comparison is made in terms of energy savings, operating cost savings, cost-effectiveness, and environmental benefits. Finally, limitations in conducting this analysis are identified and recommendations for further improving the operational efficiency of the GSHP systems are made.« less
Forced-Air Warming Discontinued: Periprosthetic Joint Infection Rates Drop.
Augustine, Scott D
2017-06-23
Several studies have shown that the waste heat from forced-air warming (FAW) escapes near the floor and warms the contaminated air resident near the floor. The waste heat then forms into convection currents that rise up and contaminate the sterile field above the surgical table. It has been shown that a single airborne bacterium can cause a periprosthetic joint infection (PJI) following joint replacement surgery. We retrospectively compared PJI rates during a period of FAW to a period of air-free conductive fabric electric warming (CFW) at three hospitals. Surgical and antibiotic protocols were held constant. The pooled multicenter data showed a decreased PJI rate of 78% following the discontinuation of FAW and a switch to air-free CFW (n=2034; P=0.002). The 78% reduction in joint implant infections observed when FAW was discontinued suggests that there is a link between the waste FAW heat and PJIs.
Forced-Air Warming Discontinued: Periprosthetic Joint Infection Rates Drop
Augustine, Scott D.
2017-01-01
Several studies have shown that the waste heat from forced-air warming (FAW) escapes near the floor and warms the contaminated air resident near the floor. The waste heat then forms into convection currents that rise up and contaminate the sterile field above the surgical table. It has been shown that a single airborne bacterium can cause a periprosthetic joint infection (PJI) following joint replacement surgery. We retrospectively compared PJI rates during a period of FAW to a period of air-free conductive fabric electric warming (CFW) at three hospitals. Surgical and antibiotic protocols were held constant. The pooled multicenter data showed a decreased PJI rate of 78% following the discontinuation of FAW and a switch to air-free CFW (n=2034; P=0.002). The 78% reduction in joint implant infections observed when FAW was discontinued suggests that there is a link between the waste FAW heat and PJIs. PMID:28713524
Evaluation of different shades to improve dairy cattle well-being in Argentina
NASA Astrophysics Data System (ADS)
Valtorta, S. E.; Leva, Perla E.; Gallardo, Miriam R.
Two tree shades (TS1 and TS2) and an artificial shade structure (AS) were evaluated using black globe temperatures (BGTs) to assess their effectiveness in reducing heat load. The artificial structure consisted of a black woven polypropylene cloth providing 80% shade, mounted on 2.5-m-high eucalyptus posts. The work was carried out at Rafaela Experimental Station, Argentina, during the summer (January and February) 1994. BGTs and floor temperatures were measured in concrete floor holding pens with and without artifical shade. The results showed no difference between TS1, TS2 and AS, their average BGTs being 30.2 (SD 0.58), 29.0 (SD 0.70) and 30.2 (SD 0.74)°C, respectively. BGTs under all three shades were significantly lower (P<0.01) than the average BGT recorded outside: 35.5 (SD 1.12)°C. Average BGTs in holding pens were 32.4 (SD 1.38) and 39.9 (SD 1.91)°C for shaded and non-shaded areas (P<0.01). The corresponding average floor temperatures were 27.8 (SD 0.68)°C and 47.7 (SD 2.13)°C (P<0.01). To assess the effects of shade on animal well-being, afternoon rectal temperatures (RT) and respiratory rate (respirations per minute, RR) of lactating cows were recorded twice a week. Rectal temperatures were significantly higher for non-shaded cows (P<0.01), mean RT being 40.1 (SD 0.65)°C vs 39.3 (SD 0.42)°C for the shaded animals. Corresponding RRs were 78.9 (SD 18.0) and 60.7 (SD 10.6) (P<0.05). It was concluded that: (1) tree and artificial shades produced similar effects, (2) shading the holding pen with an 80% shading cloth was effective in reducing heat load and floor temperatures, and (3) access to shade in our pasture-based system improved animal well-being.
Evaluation of different shades to improve dairy cattle well-being in Argentina.
Valtorta, S E; Leva, P E; Gallardo, M R
1997-11-01
Two tree shades (TS1 and TS2) and an artificial shade structure (AS) were evaluated using black globe temperatures (BGTs) to assess their effectiveness in reducing heat load. The artificial structure consisted of a black woven polypropylene cloth providing 80% shade, mounted on 2.5-m-high eucalyptus posts. The work was carried out at Rafaela Experimental Station, Argentina, during the summer (January and February) 1994. BGTs and floor temperatures were measured in concrete floor holding pens with and without artificial shade. The results showed no difference between TS1, TS2 and AS, their average BGTs being 30.2 (SD 0.58), 29.0 (SD 0.70) and 30.2 (SD 0.74) degrees C, respectively. BGTs under all three shades were significantly lower (P < 0.01) than the average BGT recorded outside: 35.5 (SD 1.12) degrees C. Average BGTs in holding pens were 32.4 (SD 1.38) and 39.9 (SD 1.91) degrees C for shaded and non-shaded areas (P < 0.01). The corresponding average floor temperatures were 27.8 (SD 0.68) degrees C and 47.7 (SD 2.13) degrees C (P < 0.01). To assess the effects of shade on animal well-being, afternoon rectal temperatures (RT) and respiratory rate (respirations per minute, RR) of lactating cows were recorded twice a week. Rectal temperatures were significantly higher for non-shaded cows (P < 0.01), mean RT being 40.1 (SD 0.65) degrees C vs 39.3 (SD 0.42) degrees C for the shaded animals. Corresponding RRs were 78.9 (SD 18.0) and 60.7 (SD 10.6) (P < 0.05). It was concluded that: (1) tree and artificial shades produced similar effects, (2) shading the holding pen with an 80% shading cloth was effective in reducing heat load and floor temperatures, and (3) access to shade in our pasture-based system improved animal well-being.
16 CFR 1209.6 - Test procedures for critical radiant flux.
Code of Federal Regulations, 2011 CFR
2011-01-01
... radiant flux of exposed attic floor insulation using a radiant heat energy source. (a) Apparatus and... ACT REGULATIONS INTERIM SAFETY STANDARD FOR CELLULOSE INSULATION The Standard § 1209.6 Test procedures... radiant heat energy panel or equivalent panel inclined at 30° above and directed at a horizontally-mounted...
16 CFR 1209.6 - Test procedures for critical radiant flux.
Code of Federal Regulations, 2012 CFR
2012-01-01
... radiant flux of exposed attic floor insulation using a radiant heat energy source. (a) Apparatus and... ACT REGULATIONS INTERIM SAFETY STANDARD FOR CELLULOSE INSULATION The Standard § 1209.6 Test procedures... radiant heat energy panel or equivalent panel inclined at 30° above and directed at a horizontally-mounted...
16 CFR 1209.6 - Test procedures for critical radiant flux.
Code of Federal Regulations, 2014 CFR
2014-01-01
... radiant flux of exposed attic floor insulation using a radiant heat energy source. (a) Apparatus and... ACT REGULATIONS INTERIM SAFETY STANDARD FOR CELLULOSE INSULATION The Standard § 1209.6 Test procedures... radiant heat energy panel or equivalent panel inclined at 30° above and directed at a horizontally-mounted...
16 CFR 1209.6 - Test procedures for critical radiant flux.
Code of Federal Regulations, 2010 CFR
2010-01-01
... radiant flux of exposed attic floor insulation using a radiant heat energy source. (a) Apparatus and... ACT REGULATIONS INTERIM SAFETY STANDARD FOR CELLULOSE INSULATION The Standard § 1209.6 Test procedures... radiant heat energy panel or equivalent panel inclined at 30° above and directed at a horizontally-mounted...
24 CFR 3280.802 - Definitions.
Code of Federal Regulations, 2010 CFR
2010-04-01
... protective devices or both, for the control of light, heat, or power circuits of small individual as well as... light, heat, or power circuits; designed to be placed in a cabinet or cutout box placed in or against a..., flexible metal conduit, electrical metallic tubing, underfloor raceways, cellular concrete floor raceways...
24 CFR 3280.802 - Definitions.
Code of Federal Regulations, 2013 CFR
2013-04-01
... protective devices or both, for the control of light, heat, or power circuits of small individual as well as... light, heat, or power circuits; designed to be placed in a cabinet or cutout box placed in or against a..., flexible metal conduit, electrical metallic tubing, underfloor raceways, cellular concrete floor raceways...
NASA Astrophysics Data System (ADS)
Zhou, Xuhong; Cao, Liang; Chen, Y. Frank; Liu, Jiepeng; Li, Jiang
2016-01-01
The developed pre-stressed cable reinforced concrete truss (PCT) floor system is a relatively new floor structure, which can be applied to various long-span structures such as buildings, stadiums, and bridges. Due to the lighter mass and longer span, floor vibration would be a serviceability concern problem for such systems. In this paper, field testing and theoretical analysis for the PCT floor system were conducted. Specifically, heel-drop impact and walking tests were performed on the PCT floor system to capture the dynamic properties including natural frequencies, mode shapes, damping ratios, and acceleration response. The PCT floor system was found to be a low frequency (<10 Hz) and low damping (damping ratio<2 percent) structural system. The comparison of the experimental results with the AISC's limiting values indicates that the investigated PCT system exhibits satisfactory vibration perceptibility, however. The analytical solution obtained from the weighted residual method agrees well with the experimental results and thus validates the proposed analytical expression. Sensitivity studies using the analytical solution were also conducted to investigate the vibration performance of the PCT floor system.
McDonald, Douglas B.; Buchholz, Carol E.
1994-01-01
A shield for restricting molten corium from flowing into a water sump disposed in a floor of a containment vessel includes upper and lower walls which extend vertically upwardly and downwardly from the floor for laterally bounding the sump. The upper wall includes a plurality of laterally spaced apart flow channels extending horizontally therethrough, with each channel having a bottom disposed coextensively with the floor for channeling water therefrom into the sump. Each channel has a height and a length predeterminedly selected for allowing heat from the molten corium to dissipate through the upper and lower walls as it flows therethrough for solidifying the molten corium therein to prevent accumulation thereof in the sump.
NASA Technical Reports Server (NTRS)
1979-01-01
The heating units shown in the accompanying photos are Panelbloc infrared heaters, energy savers which burn little fuel in relation to their effective heat output. Produced by Bettcher Manufacturing Corporation, Cleveland, Ohio, Panelblocs are applicable to industrial or other facilities which have ceilings more than 12 feet high, such as those pictured: at left the Bare Hills Tennis Club, Baltimore, Maryland and at right, CVA Lincoln- Mercury, Gaithersburg, Maryland. The heaters are mounted high above the floor and they radiate infrared energy downward. Panelblocs do not waste energy by warming the surrounding air. Instead, they beam invisible heat rays directly to objects which absorb the radiation- people, floors, machinery and other plant equipment. All these objects in turn re-radiate the energy to the air. A key element in the Panelbloc design is a coating applied to the aluminized steel outer surface of the heater. This coating must be corrosion resistant at high temperatures and it must have high "emissivity"-the ability of a surface to emit radiant energy. The Bettcher company formerly used a porcelain coating, but it caused a production problem. Bettcher did not have the capability to apply the material in its own plant, so the heaters had to be shipped out of state for porcelainizing, which entailed extra cost. Bettcher sought a coating which could meet the specifications yet be applied in its own facilities. The company asked The Knowledge Availability Systems Center, Pittsburgh, Pennsylvania, a NASA Industrial Applications Center (IAC), for a search of NASA's files
Recent geologic history of lake Atitlán, a caldera lake in western Guatemala
Newhall, C.G.; Paull, C.K.; Bradbury, J.P.; Higuera-Gundy, A.; Poppe, L.J.; Self, S.; Bonar, Sharpless N.; Ziagos, J.
1987-01-01
Heat-flow measurements inside and just outside the caldera are high (290 and 230 mW m−2), suggesting hydrothermal convection and a shallow heat source. High heat flow, a geological record of post-caldera silicic eruptions, and unexplained fluctuations of lake level (episodic tumescence ofthe lake floor?) suggest that magma remains beneath Lake Atitlán and that future eruptions are possible.
16 CFR § 1209.6 - Test procedures for critical radiant flux.
Code of Federal Regulations, 2013 CFR
2013-01-01
... radiant flux of exposed attic floor insulation using a radiant heat energy source. (a) Apparatus and... SAFETY ACT REGULATIONS INTERIM SAFETY STANDARD FOR CELLULOSE INSULATION The Standard § 1209.6 Test... radiant heat energy panel or equivalent panel inclined at 30° above and directed at a horizontally-mounted...
Evaluation of Ultra High Pressure (UHP) Firefighting in a Room-and-Contents Fire
2017-03-15
Burn Room and Hangar Temperature Prior to Ignition ............................................... 18 Figure 12. Effect of Temperature on Normalized...Figure 20. Maximum Average Temperature and Heat Flux ......................................................... 22 Figure 21. Effect of Maximum Average...Aspirated Ceiling Temperature .................................... 23 Figure 22. Effect of Maximum Average Floor Heat Flux on Extinguishment Quantity
Initial evaluation of floor cooling on lactating sows under severe acute heat stress
USDA-ARS?s Scientific Manuscript database
The objectives were to evaluate an acute heat stress protocol for lactating sows and evaluate preliminary estimates of water flow rates required to cool sows. Twelve multiparous sows were provided with a cooling pad built with an aluminum plate surface, high-density polyethylene base and copper pipe...
Oceanic lithosphere and asthenosphere - Thermal and mechanical structure
NASA Technical Reports Server (NTRS)
Schubert, G.; Yuen, D. A.; Froidevaux, C.
1976-01-01
A coupled thermomechanical subsolidus model of the oceanic lithosphere and asthenosphere is developed which includes vertical heat conduction, a temperature-dependent thermal conductivity, heat advection by a horizontal and vertical mass flow that depends on depth and age, contributions of viscous dissipation or shear heating, a linear or nonlinear deformation law relating shear stress and strain rate, as well as a temperature- and pressure-dependent viscosity. The model requires a constant horizontal velocity and temperature at the surface, but zero horizontal velocity and constant temperature at great depths. The depth- and age-dependent temperature, horizontal and vertical velocities, and viscosity structure of the lithosphere and asthenosphere are determined along with the age-dependent shear stress in those two zones. The ocean-floor topography, oceanic heat flow, and lithosphere thickness are deduced as functions of ocean-floor age; seismic velocity profiles which exhibit a marked low-velocity zone are constructed from the age-dependent geotherms and assumed values of the elastic parameters. It is found that simple boundary-layer cooling determines the thermal structure at young ages, while effects of viscous dissipation become more important at older ages.
Thermal Analysis for Ion-Exchange Column System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Si Y.; King, William D.
2012-12-20
Models have been developed to simulate the thermal characteristics of crystalline silicotitanate ion exchange media fully loaded with radioactive cesium either in a column configuration or distributed within a waste storage tank. This work was conducted to support the design and operation of a waste treatment process focused on treating dissolved, high-sodium salt waste solutions for the removal of specific radionuclides. The ion exchange column will be installed inside a high level waste storage tank at the Savannah River Site. After cesium loading, the ion exchange media may be transferred to the waste tank floor for interim storage. Models weremore » used to predict temperature profiles in these areas of the system where the cesium-loaded media is expected to lead to localized regions of elevated temperature due to radiolytic decay. Normal operating conditions and accident scenarios (including loss of solution flow, inadvertent drainage, and loss of active cooling) were evaluated for the ion exchange column using bounding conditions to establish the design safety basis. The modeling results demonstrate that the baseline design using one central and four outer cooling tubes provides a highly efficient cooling mechanism for reducing the maximum column temperature. In-tank modeling results revealed that an idealized hemispherical mound shape leads to the highest tank floor temperatures. In contrast, even large volumes of CST distributed in a flat layer with a cylindrical shape do not result in significant floor heating.« less
Prevention of Salmonella cross-contamination in an oilmeal manufacturing plant.
Morita, T; Kitazawa, H; Iida, T; Kamata, S
2006-08-01
The mechanisms of Salmonella contamination in an oilmeal plant were investigated and the basic data were collected in order to achieve control of Salmonella in oilmeal. Salmonella was detected in all contamination vectors and environmental factors investigated, namely: operators, processing floor, dust in the air and rodents. In particular, high concentrations of Salmonella were detected on the processing floor of the manufacturing area, which has high oil content. Steam was the most effective disinfection method used for the processing floor, as the effects of heat sterilization and disinfection may work in tandem. In addition, restricting the movement of operators of the production chain remarkably reduced Salmonella contamination, even in areas of otherwise high contamination. Within the oilmeal plant, high Salmonella contamination rates for the processing floor represent the greatest risk of contamination of oilmeal via operators, dust in the air and rodents. Therefore, control of the processing floor is the most important means for reducing the oilmeal contamination rate. Specific Salmonella control methods for oilmeal plants have been established.
An engineering analysis of a closed cycle plant growth module
NASA Technical Reports Server (NTRS)
Stickford, G. H., Jr.; Jakob, F. E.; Landstrom, D. K.
1986-01-01
The SOLGEM model is a numerical engineering model which solves the flow and energy balance equations for the air flowing through a growing environment, assuming quasi-steady state conditions within the system. SOLGEM provides a dynamic simulation of the controlled environment system in that the temperature and flow conditions of the growing environment are estimated on an hourly basis in response to the weather data and the plant growth parameters. The flow energy balance considers the incident solar flux; incoming air temperature, humidity, and flow rate; heat exchange with the roof and floor; and heat and moisture exchange with the plants. A plant transpiration subroutine was developed based plant growth research facility, intended for the study of bioregenerative life support theories. The results of a performance analysis of the plant growth module are given. The estimated energy requirements of the module components and the total energy are given.
Surfactant effects on heat transfer at gas/liquid interfaces
NASA Astrophysics Data System (ADS)
Lopez, J. M.; Hirsa, A. H.
2000-01-01
A formulation of a canonical model to elucidate the interplay and competition between three primary sources of heat and mass transfer in non-isothermal systems with gas/liquid interfaces is presented. The nonlinear interaction between (i) buoyancy driven flow in the bulk, (ii) thermal Marangoni flow at the gas/liquid interface, and (iii) surfactant Marangoni flow at the interface is considered. A numerical model of the Navier-Stokes and energy equations is being developed for a simple, axisymmetric flow geometry. The boundary conditions for the Navier-Stokes equations are functions of the intrinsic viscoelastic properties of the interface, specifically the surface tension and the surface viscosities. A flow geometry which is amenable to both experiments and computations for elucidating the separate effects of the three mechanisms consists of an annular region bounded by a stationary inner and an outer cylinder and floor, and a free surface. The flow is driven by the temperature difference between the inner and outer cylinder which are set independently, and the floor is insulated. The predictions of the model for earth-g can be compared to laboratory measurements of the velocity field, and the surface temperature distribution. The predictions of the model for arbitrary gravity may be subsequently tested in the microgravity environment. .
Foundation Design against Frost Action in Europe.
1988-03-01
the inside of the foundation wall and consisted of 50mm of ’Rockwool’ (a mineral wool ). This insulation guides heat from the house down toward the...Separation of the floor slab from the inner part of the foundation wall by introducing mineral wool (Fig. 49c) gives a further slight reduction in...construction consisting, for example, of wood and mineral wool and including air spaces. Rt is the thermal resistance of the composite floor from surface to
2016-02-01
complete breaks in the floors, walls, and ceilings that divide the building into discrete sections. The objectives of this inspection were to... ceiling panels, as well as fire suppression pumps, fire alarms, and communications lines. We found other deficiencies not identified by AFCEC that...structural components suspended from the ceiling or floor above, such as heating/cooling equipment, duct work, dropped ceilings , electrical fixtures
Human thermal physiological and psychological responses under different heating environments.
Wang, Zhaojun; Ning, Haoran; Ji, Yuchen; Hou, Juan; He, Yanan
2015-08-01
Anecdotal evidence suggests that many residents of severely cold areas of China who use floor heating (FH) systems feel warmer but drier compared to those using radiant heating (RH) systems. However, this phenomenon has not been verified experimentally. In order to validate the empirical hypothesis, and research the differences of human physiological and psychological responses in these two asymmetrical heating environments, an experiment was designed to mimic FH and RH systems. The subjects participating in the experiment were volunteer college-students. During the experiment, the indoor air temperature, air speed, relative humidity, globe temperature, and inner surface temperatures were measured, and subjects' heart rate, blood pressure and skin temperatures were recorded. The subjects were required to fill in questionnaires about their thermal responses during testing. The results showed that the subjects' skin temperatures, heart rate and blood pressure were significantly affected by the type of heating environment. Ankle temperature had greatest impact on overall thermal comfort relative to other body parts, and a slightly cool FH condition was the most pleasurable environment for sedentary subjects. The overall thermal sensation, comfort and acceptability of FH were higher than that of RH. However, the subjects of FH felt drier than that of RH, although the relative humidity in FH environments was higher than that of the RH environment. In future environmental design, the thermal comfort of the ankles should be scrutinized, and a FH cool condition is recommended as the most comfortable thermal environment for office workers. Consequently, large amounts of heating energy could be saved in this area in the winter. The results of this study may lead to more efficient energy use for office or home heating systems. Copyright © 2015 Elsevier Ltd. All rights reserved.
76 FR 19488 - Exelon Generation Company, LLC, Oyster Creek Nuclear Generating Station; Exemption
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-07
... fuel sources consisting primarily of cable insulation and limited floor based combustibles except areas... heat or smoke that may be produced during a fire event. Additionally, the main combustible in this area... the area is open to the atmosphere with no walls or ceiling to contain the heat or smoke that may be...
The influence of the environment on dairy cow behavior, claw health and herd lameness dynamics.
Cook, Nigel B; Nordlund, Kenneth V
2009-03-01
Free stall housing increases the exposure of dairy cows' claws to concrete walk-ways and to manure between periods of rest, and generally shows the highest rate of lameness compared with other dairy management systems. However, there is great variation within a system, and the rate of new cases of lameness can be reduced to very low levels provided time spent resting per day is maximized through good stall design, access to stalls through stocking density control and comfortable transition cow facilities, limiting the time spent milking, provision of adequate heat abatement, and good leg hygiene. Sand bedded stalls are useful as they also permit lame cows to maintain adequate daily rest. Rubberized alley flooring surfaces benefit the cow by reducing claw wear and trauma compared to concrete, making them ideal for parlor holding areas and long transfer lanes and walk ways. However, caution is required when using rubber floors in pens with uncomfortable stalls due to apparent adverse effects on cow time budgets, which may in turn have a detrimental effect on lameness.
Effect of Different Flooring Designs on the Performance and Foot Pad Health in Broilers and Turkeys.
Chuppava, Bussarakam; Visscher, Christian; Kamphues, Josef
2018-05-03
Litter quality has a significant influence on the performance and foot pad health in poultry. The objective of this study was to evaluate the effects of different types of flooring designs on the performance and foot pad health in fattening broilers and turkeys. Three trials were conducted for each species using a total of 720 Ross 308 broilers and 720 Big 6 turkeys. After day seven, animals were randomly assigned to four groups with three subgroups each: G1—floor pens with litter, G2—floor pens with litter and floor heating, G3—partially-slatted flooring, including a littered area, and G4—fully-slatted flooring with a sand bath (900 cm²). Animals of both species had a significantly higher final body weight at dissection (day 36) after being reared on fully-slatted floors compared to common littered floors. In turkeys, the feed conversion ratio was worse in G4 (1.53 ± 0.04) than in G1 (1.47 ± 0.02) and G2 (1.48 ± 0.03). Water to feed ratio was significantly higher in G2 than other groups. Turkeys’ foot pad health was significantly better in G4 than in other groups beginning at day 21. In turkeys, platforms with slatted floors that allow for temporary separation of the feet from the litter could lead to improvements in foot pad health which could better enable the realization of species-specific behaviours and activities in littered areas.
Dormitory renovation project reduces energy use by 69%
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kokayko, M.J.
1997-06-01
Baldwin Hall is a three-story, 46,000 ft{sup 2} (4,273 m{sup 1}) dormitory on the campus of Allegheny College in Meadville, Pa. The building was originally built in the 1950s; an additional wing was added in the 1970s so that it has about 37,000 ft{sup 2} (3,437 m{sup 2}). The building contains approximately 100 double-occupancy student rooms; three common bathroom groups per floor; central study, lounge, and computer areas; and a laundry. Design for the renovation started in the winter of 1993; construction took place in the summer of 1994. The major goals of the renovation were: (1) to replace themore » entire building heating system (central boiler plant, distribution piping, and room heating terminals); (2) add a ventilation system within the building; (3) upgrade the building electrical system; (4) provide computer data cabling and cable TV wiring to each room; and, (5) improve room and hallway lighting and finishes.« less
Turbulent Supersonic/Hypersonic Heating Correlations for Open and Closed Cavities
NASA Technical Reports Server (NTRS)
Everhart, Joel L.; Greene, Francis A.
2009-01-01
Supersonic/hypersonic laminar heating correlations that were developed for damage assessment analysis of atmospheric re-entry vehicles have been modified and extended to cover fully-turbulent conditions over rectangular cavity geometries that are aligned with the local velocity. Turbulent boundary layer properties were computationally determined and used to develop the cavity geometry parametrics and to correlate experimental closed cavity heating data to yield new relationships for the floor-averaged and centerline endwall peak-heating augmentation. With the form of the closed-cavity correlations established, historical data were used to develop new correlations for turbulent open-cavity heating.
2012-06-01
could either be accomplished by installing a solar heating panel on the roof of each of the 104 buildings or having a solar photovoltaic array...Prior to 1981 , ACMs were used extensively in plaster, wall board, joint compound, felt material , roofing material , floor tile , mastic, piping...5 5.4. Alternative D-lnstall Solar Heating Panels or Solar Photovoltaic Array ......................... 5 5.5. Alternative E
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martin, M.A.; Durfee, D.J.; Hughes, P.J.
1999-06-19
The Lincoln Public School District, in Lincoln, Nebraska, recently installed vertical-bore geothermal heat pump systems in four, new, elementary schools. Because the district has consistent maintenance records and procedures, it was possible to study repair, service and corrective maintenance requests for 20 schools in the district. Each school studied provides cooling to over 70% of its total floor area and uses one of the following heating and cooling systems: vertical-bore geothermal heat pumps (GHPs), air-cooled chiller with gas-fired hot water boiler (ACUGHWB), water-cooled chiller with gas-fired hot water boiler (WCCYGHWB), or water-cooled chiller with gas-fired steam boiler (WCUGSB). Preventative maintenancemore » and capital renewal activities were not included in the available database. GHP schools reported average total costs at 2.13 cents/ft{sup 2}-yr, followed by ACC/GHWB schools at 2.88 cents/ft{sup 2}-yr, WCC/GSB schools at 3.73 cents/ft{sup 2}-yr, and WCC/GHWB schools at 6.07 cents/ft{sup 2}-yr. Because of tax-exemptions on material purchases, a reliance on in-house labor, and the absence of preventative maintenance records in the database, these costs are lower than those reported in previous studies. A strong relationship (R{sup 2}=O.52) was found between costs examined and cooling system age: the newer the cooling equipment, the less it costs to maintain.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martin, M.A.; Durfee, D.J.; Hughes, P.J.
1999-07-01
The Lincoln Public School District, in Lincoln, Nebraska, recently installed vertical-bore geothermal heat pump systems in four new elementary schools. Because the district has consistent maintenance records and procedures, it was possible to study repair, service, and corrective maintenance requests for 20 schools in the district. Each school studied provides cooling to over 70% of its total floor area and uses one of the following heating and cooling systems: vertical-bore geothermal heat pumps (GHPs), air-cooled chiller with gas-fired hot water boiler (ACC/GHWB), water-cooled chiller with gas-fired hot water boiler (WCC/GHWB), or water-cooled chiller with gas-fired steam boiler (WCC/GSB). Preventative maintenancemore » and capital renewal activities were not included in the available database. GHP schools reported average total costs at 2.13{cents}/ft{sup 2}-yr, followed by ACC/GHWB schools at 2.884{cents}/ft{sup 2}-yr, WCC/GSB schools at 3.73{cents}/ft{sup 2}-yr, and WCC/GHWB schools at 6.07{cents}/ft{sup 2}-yr. Because of tax exemptions on material purchases, a reliance on in-house labor, and the absence of preventative maintenance records in the database, these costs are lower than those reported in previous studies. A strong relationship (R{sup 2} = 0.52) was found between costs examined and cooling system age: the newer the cooling equipment, the less it costs to maintain.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
none,
This case study describes a DOE Zero Energy Ready Home in Greenbank, Washington that scored HERS 37 without PV and a -5 with PV. This 1,955 ft2 custom home has 6.5-inch structural insulated panel (SIPs) walls, a 10.25-inch SIPS roof, an R-20 insulated slab, a 2-ton ground source heat pump, radiant floor heat, 7.1 kWh PV, and triple-pane windows.
An experimental parametric study of VOC from flooring systems exposed to alkaline solutions.
Sjöberg, A; Ramnäs, O
2007-12-01
This study outlined the influence of a number of parameters affecting the emission rate from one of the largest sources of VOC in the building stock in the Nordic countries. This source is flooring systems of polyvinyl chloride or linoleum attached to a substrate of moisture damaged or insufficiently dried concrete. The secondary emission rate of degradation products was measured, with the Field and Laboratory Emission Cell, on different flooring systems consisting of three different floorings and three adhesives, exposed to three different aqueous solutions in the range of 11-13.1 pH. The conclusion drawn in this study is that the great majority of the secondary emission originates from the floor adhesive. The occurrence of adhesive and the amount of adhesive used have a significant influence on the emission rate. A critical pH value for degradation of the adhesive seems to lie somewhere between 11 and 13 pH. When designing a floor system or a renovation of a damaged flooring system, it is important to bear in mind the influence of parameters that may drastically shorten the service life. Flooring adhesive may decompose in a moist alkaline environment and give rise to unacceptable secondary emission rates.
Integrated energy system for a high performance building
NASA Astrophysics Data System (ADS)
Jaczko, Kristen
Integrated energy systems have the potential to reduce of the energy consumption of residential buildings in Canada. These systems incorporate components to meet the building heating, cooling and domestic hot water load into a single system in order to reduce energy losses. An integrated energy system, consisting of a variable speed heat pump, cold and hot thermal storage tanks, a photovoltaic/thermal (PV/T) collector array and a battery bank, was designed for the Queen's Solar Design Team's (QSDT) test house. The system uses a radiant floor to provide space- heating and sensible cooling and a dedicated outdoor air system provides ventilation and dehumidifies the incoming fresh air. The test house, the Queen's Solar Education Centre (QSEC), and the integrated energy system were both modelled in TRNSYS. Additionally, a new TRNSYS Type was developed to model the PV/T collectors, enabling the modeling of the collection of energy from the ambient air. A parametric study was carried out in TRNSYS to investigate the effect of various parameters on the overall energy performance of the system. These parameters included the PV/T array size and the slope of the collectors, the heat pump source and load-side inlet temperature setpoints, the compressor speed control and the size of the thermal storage tanks and the battery bank. The controls of the heat pump were found to have a large impact on the performance of the integrated energy system. For example, a low evaporator setpoint improved the overall free energy ratio (FER) of the system but the heat pump performance was lowered. Reducing the heat loss of the PV/T panels was not found to have a large effect on the system performance however, as the heat pump is able to lower the inlet collector fluid temperature, thus reducing thermal losses. From the results of the sensitivity study, a recommended system model was created and this system had a predicted FER of 77.9% in Kingston, Ontario, neglecting the energy consumption of circulation pumps and fans. Simulations of the recommended integrated energy system were also performed in several other Canadian cities and the predicted FER was above 60% in all except for the most northern city investigated, Yellowknife. Thus, the integrated energy system has the potential of reducing the energy consumption of residential buildings in Canada.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-13
..., shapes, grommets, clamps, hose, fittings, floor mats, gaskets, seals, insulation and lenses); v-ribbed...); compressors; fans (blades); turbochargers; air conditioners; heat exchangers; filters; windshield washer...
NASA Astrophysics Data System (ADS)
Lowell, R. P.; Lata, C.
2016-12-01
The aim of this work is to model heat output from a cooling, convective, crystallizing, and replenished basaltic magma sill, representing an axial magma lens (AML) at mid oceanic ridges. As a simplified version of basaltic melt, we have assumed the melt to be a two-component eutectic system composed of diopside and anorthite. Convective vigor is expressed through the Rayleigh number and heat flux is scaled through a classical relationship between the Rayleigh number and Nusselt number, where the temperature difference driving the convective heat flux is derived from a "viscous" temperature scale reflecting the strong temperature dependent viscosity of the system. Viscosity is modeled as a function of melt composition and temperature using the Tammann-Vogel-Fulcher equation, with parameters fit to the values of observed viscosities along the diopside-anorthite liquidus. It was observed for the un-replenished case, in which crystals fall rapidly to the floor of the AML, model results show that the higher initial concentration of diopside, the more vigorous the convection and the faster the rate of crystallization and decay of heat output. Replenishment of the AML accompanied by modest thickening of the melt layer stabilizes the heat output at values similar to those observed at ridge-axis hydrothermal systems. This study is an important step forward in quantitative understanding of thermal evolution of the axial magma lens at a mid-ocean ridge and the corresponding effect on high-temperature hydrothermal systems. Future work could involve improved replenishment mechanisms, more complex melts, and direct coupling with hydrothermal circulation models.
Fraver, Shawn; Jain, Theresa; Bradford, John B; D'Amato, Anthony W; Kastendick, Doug; Palik, Brian; Shinneman, Doug; Stanovick, John
2011-09-01
Although primarily used to mitigate economic losses following disturbance, salvage logging has also been justified on the basis of reducing fire risk and fire severity; however, its ability to achieve these secondary objectives remains unclear. The patchiness resulting from a sequence of recent disturbances-blowdown, salvage logging, and wildfire-provided an excellent opportunity to assess the impacts of blowdown and salvage logging on wildfire severity. We used two fire-severity assessments (tree-crown and forest-floor characteristics) to compare post-wildfire conditions among three treatment combinations (Blowdown-Salvage-Fire, Blowdown-Fire, and Fire only). Our results suggest that salvage logging reduced the intensity (heat released) of the subsequent fire. However, its effect on severity (impact to the system) differed between the tree crowns and forest floor: tree-crown indices suggest that salvage logging decreased fire severity (albeit with modest statistical support), while forest-floor indices suggest that salvage logging increased fire severity. We attribute the latter finding to the greater exposure of mineral soil caused by logging operations; once exposed, soils are more likely to register the damaging effects of fire, even if fire intensity is not extreme. These results highlight the important distinction between fire intensity and severity when formulating post-disturbance management prescriptions.
Fraver, S.; Jain, T.; Bradford, J.B.; D'Amato, A.W.; Kastendick, D.; Palik, B.; Shinneman, D.; Stanovick, J.
2011-01-01
Although primarily used to mitigate economic losses following disturbance, salvage logging has also been justified on the basis of reducing fire risk and fire severity; however, its ability to achieve these secondary objectives remains unclear. The patchiness resulting from a sequence of recent disturbances-blowdown, salvage logging, and ildfire- provided an excellent opportunity to assess the impacts of blowdown and salvage logging on wildfire severity. We used two fire-severity assessments (tree-crown and forest-floor characteristics) to compare post-wildfire conditions among three treatment combinations (Blowdown-Salvage-Fire, Blowdown-Fire, and Fire only). Our results suggest that salvage logging reduced the intensity (heat released) of the subsequent fire. However, its effect on severity (impact to the system) differed between the tree crowns and forest floor: tree-crown indices suggest that salvage logging decreased fire severity (albeit with modest statistical support), while forest-floor indices suggest that salvage logging increased fire severity. We attribute the latter finding to the greater exposure of mineral soil caused by logging operations; once exposed, soils are more likely to register the damaging effects of fire, even if fire intensity is not extreme. These results highlight the important distinction between fire intensity and severity when formulating post-disturbance management prescriptions. ?? 2011 by the Ecological Society of America.
Radon mitigation at Birch Cliff Public School.
Moridi, R; Becker, E
1996-01-01
In 1991, Canadian Institute for Radiation Safety (CAIRS) conducted a radon screening program in all Metropolitan Toronto public schools. Birch Cliff Public School had a radon progeny level higher than the action level of 4.16 x 10(-7) Jm-3 (20 mWL). Follow-up radon testing was carried out at the school. Locations on the ground floor and in the basement were tested. All locations on the ground floor had radon progeny levels below the action level. Six locations in the basement had readings above the action level. All cracks and openings in the basement were sealed and a new heating/ventilating (HV) system for the basement was designed and installed. Then, the basement was tested again. Radon progeny levels are now well below the action level with an average of 7.43 x 10(-8) Jm-3 (3.57 mWL). This is about one fifth of the average radon progeny level found in the first stage of follow-up testing.
NASA Astrophysics Data System (ADS)
Christenson, B. W.; White, S.; Britten, K.; Scott, B. J.
2017-10-01
White Island has a long and varied history of acid spring discharge and shallow ephemeral lake formation on its main crater floor. In the 12 months prior to the onset of the 1976-2000 eruptive episode, mass discharge from the spring system increased ca. 10-fold, pointing to a strong coupling of the hydrothermal environment to the evolving magmatic system. Between 1976 and 1978, the formation of numerous eruption vents to 200 m depth in the Western Sub-crater abruptly changed the hydraulic gradients in the volcano, resulting in the reversal of groundwater flow in the massif towards the newly-formed crater(s). This affected not only the style of volcanic activity (leading to phreatic-phreatomagmatic-magmatic eruption cycles), but also led to the demise of the spring system, with discharge from the main crater declining by a factor > 100 by 1979. Eruptive activity ended shortly after a moderate Strombolian eruption in mid-2000, after which ephemeral lakes started to form in the eruption crater complex. Between 2003 and 2015 there were three complete lake filling and evaporative cycles, reflecting varying heat flow through the conduit system beneath the lake. Over these cycles, lake water concentrations of Cl and SO4 varied between ca. 35-150 and 5-45 g/L respectively, with pH values temporally ranging from + 1.5 to - 1. Springs appeared on the Main Crater floor in 2004, and their discharges varied with lake level, pointing to the lake level being a primary control over the piezometric surface in the crater area. Springs closest to the crater complex show direct evidence of crater lake water infiltration into the crater floor aquifer, whereas distal spring discharges show compositional variations reflecting vertical displacement of the interface between shallow, dilute condensate and underlying acidic brine fluids. Source components for the spring fluids include magmatic vapour, dissolved andesitic host rocks, seawater and meteoric water. Lake waters, on the other hand, consist predominantly of magmatic vapour, meteoric water and solutes derived from host andesites and their altered derivatives. δ2H and δ18O signatures of the enclosing acid brine fluids, indicate they are predominantly seawater which have been affected by both vapour loss, but also mixing with arc-type vapour. An interesting finding of this study is that crater floor deformation correlates directly to both lake level and volatile emissions, in an apparent poroelastic response to the establishment of a hydrostatic water column in the eruption crater complex, and a net decrease in permeability owing to hydrothermal mineralization in the conduit (predominantly elemental sulfur and sulfate minerals). The hydrostatic pressurization of the vent environment also leads to increased gas pressures and flows through fumarolic channels, and consequent expansion of fumarolic areas on the main crater floor. A period of unrest, which commenced in August 2012 and lasted until October 2013, included the extrusion of a small dome into the eruption crater complex. This activity, and related high heat flow, led once again to evaporation of the lake, and ongoing phreatic eruption activity which has provided interesting insights into the role which elemental sulfur, associated hydrothermal alteration minerals and of course water play in regulating pressures in the magmatic-hydrothermal environment.
A pilot study on the improvement of the lying area of finishing pigs by a soft lying mat.
Savary, Pascal; Gygax, Lorenz; Jungbluth, Thomas; Wechsler, Beat; Hauser, Rudolf
2011-01-01
In this pilot study, we tested whether a soft mat (foam covered with a heat-sealed thermoplastic) reduces alterations and injuries at the skin and the leg joints.The soft mat in the lying area of partly slatted pens was compared to a lying area consisting of either bare or slightly littered (100 g straw per pig and day) concrete flooring. In this study we focused on skin lesions on the legs of finishing pigs as indicators of impaired welfare. Pigs were kept in 19 groups of 8-10 individuals and were examined for skin lesions around the carpal and tarsal joints either at a weight of <35 kg, or at close to 100 kg. The likelihood of hairless patches and wounds at the tarsal joints was significantly lower in pens with the soft lying mat than in pens with a bare concrete floor. Pens with a littered concrete floor did not differ compared to pens with a bare concrete floor. The soft lying mat thus improved floor quality in the lying area in terms of preventing skin lesions compared to bare and slightly littered concrete flooring. Such soft lying mats have thus the potential to improve lying comfort and welfare of finishing pigs.
Turbulent Supersonic/Hypersonic Heating Correlations for Open and Closed Cavities
NASA Technical Reports Server (NTRS)
Everhart, Joel L.; Greene, Francis A.
2009-01-01
Supersonic/hypersonic laminar heating correlations that were developed for damage assessment analysis of atmospheric re-entry vehicles have been modified and extended to cover fully-turbulent conditions over rectangular cavity geometries that are aligned with the local velocity. Turbulent boundary layer properties were computationally determined and used to develop the cavity geometry parametrics and to correlate experimental closed cavity heating data to yield new relationships for the floor-averaged and centerline endwall peakheating augmentation. With the form of the closed-cavity correlations established, historical data were used to develop new correlations for turbulent open-cavity heating.
Deterioration of the Floor of Interior Courtyard of Sultan Hassan Mosque in Cairo, Egypt.
NASA Astrophysics Data System (ADS)
Nazel, Tarek
The college- mosque of Sultan Hassan is considered one of the finest examples of Islamic architecture not only in Egypt but also in the East. Its open interior courtyard is paved with three different types of marble slabs. These marble slabs suffer from severe deterioration. Causes of this deterioration were determined accurately through the ocular examination of the courtyard and confirmed by the laboratory tests which were carried out on samples representing the three common types of marble used in the floor namely the white, the red and the black marble. Sun light and heat are the main deterioration factors and the consequent thermal expansion is the main property which led to the detected deterioration phenomena. Types and mechanisms of deterioration affected the floor were described and explained.
Comparison of claw health and milk yield in dairy cows on elastic or concrete flooring.
Kremer, P V; Nueske, S; Scholz, A M; Foerster, M
2007-10-01
This article reports on the effects of elastic (rubber) flooring compared with concrete flooring on claw health and milk yield in dairy cows. Milk yield and activity data of 53 complete lactations from 49 cows were recorded by an automatic milking system in the University of Munich Livestock Center dairy herd. Cows were kept in a loose housing system on concrete-slatted or rubber-matted slatted flooring. Claws were trimmed and measured linearly in combination with claw lesion diagnosis 3 times during one lactation period (including the transition phase). An automatic milking system recorded milk yield and activity. The net horn growth of the claws increased on elastic flooring. Therefore, correct and frequent claw trimming is at least as important for claw health in dairy herds kept on rubber flooring as for those on concrete-slatted flooring. Cows housed on rubber had an increased incidence of sole ulcers. Sole hemorrhages (except for hemorrhages associated with sole ulcers) occurred less frequently on rubber than on concrete. Results concerning digital dermatitis were difficult to assess, because manual manure scraping on rubber required sprinkling the flooring twice daily, which additionally moistened the digital skin of the cows. This might explain the greater incidence of digital dermatitis on elastic flooring. The incidence of clinically lame cows did not differ between flooring types. Cows showed greater activity on rubber, most likely caused by the more comfortable walking surface compared with the concrete-slatted flooring. The greater activity may indicate better overall health of high-yielding dairy cows on rubber flooring. Milk yield, however, did not differ between flooring types.
Thermal oxidation saves $500,000, lifts capacity, upholds compliance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harley, C.G.; Nagy, A.J.; Sendecki, M.
1985-12-01
The age and destruction of the heat recovery system dictated the replacement of the original fume incinerator at the Congoleum Resilient Flooring Division Plant in Trenton, NJ. The original unit, installed in 1967, had a conventional air-to-oil heat recovery system. Plant personnel placed high priority on finding a replacement with a higher thermal efficiency while still maintaining environmental integrity. A proprietary software program was used to obtain values for NPV (net pressure value) for several competitive equipment systems. The NPV allows simple comparison of equipment based on data such as purchase pgsrice, cost of installation, operating costs, and maintenance costsmore » for the predicted life span of each unit. Based on NPV analysis, a regenerative thermal oxidation unit was selected. To assure expansion capability, Congoleum opted for a 30,000 scfm system. The regenerative thermal oxidation unit consists of a central combustion chamber with five lobes extending radially outward. Each lobe is packed with ceramic refractory elements (saddles) which serve as heat exchange media. The elements are retained by perforated refractory blocks on the hot combustion chamber side and by a grating on the cold side. Estimated savings from the system, about a half million dollars the first year, are expected to significantly exceed Congoleum's original estimates. About half of the total savings will result from reduced consumption of natural gas since the unit is fueled mainly by the organic material in the process exhaust. The other half of the savings has resulted from improvements in production efficiency and the recycling of waste heat from the thermal oxidizer.« less
8. Several of the rental rooms are joined by doors, ...
8. Several of the rental rooms are joined by doors, and each room is accessed from the corridor. Originally, the transoms were glazed. When a central heating/cooling system was installed, the transoms were modified to accommodate air grilles that are supplied by a duct located in the corridor. The five-panel door and wood wainscot are original features. However, the wainscot does not occur in every room. The lath and plaster partitions and the wood flooring are typical of the original construction. Credit GADA/MRM. - Stroud Building, 31-33 North Central Avenue, Phoenix, Maricopa County, AZ
2012-06-28
CAPE CANAVERAL, Fla. - The transportation canister holding the Orion crew module rests on the floor of the Operations and Checkout Building high bay at NASA's Kennedy Space Center in Florida. Slated for Exploration Flight Test-1, an uncrewed mission planned for 2014, the capsule will travel farther into space than any human spacecraft has gone in more than 40 years. NASA's Michoud Assembly Facility in New Orleans built the crew module pressure vessel. The Orion production team will prepare the module for flight by installing heat-shielding thermal protection systems, avionics and other subsystems. For more information, visit http://www.nasa.gov/orion. Photo credit: NASA/Charisse Nahser
Navier-Stokes Simulation of Airconditioning Facility of a Large Modem Computer Room
NASA Technical Reports Server (NTRS)
2005-01-01
NASA recently assembled one of the world's fastest operational supercomputers to meet the agency's new high performance computing needs. This large-scale system, named Columbia, consists of 20 interconnected SGI Altix 512-processor systems, for a total of 10,240 Intel Itanium-2 processors. High-fidelity CFD simulations were performed for the NASA Advanced Supercomputing (NAS) computer room at Ames Research Center. The purpose of the simulations was to assess the adequacy of the existing air handling and conditioning system and make recommendations for changes in the design of the system if needed. The simulations were performed with NASA's OVERFLOW-2 CFD code which utilizes overset structured grids. A new set of boundary conditions were developed and added to the flow solver for modeling the roomls air-conditioning and proper cooling of the equipment. Boundary condition parameters for the flow solver are based on cooler CFM (flow rate) ratings and some reasonable assumptions of flow and heat transfer data for the floor and central processing units (CPU) . The geometry modeling from blue prints and grid generation were handled by the NASA Ames software package Chimera Grid Tools (CGT). This geometric model was developed as a CGT-scripted template, which can be easily modified to accommodate any changes in shape and size of the room, locations and dimensions of the CPU racks, disk racks, coolers, power distribution units, and mass-storage system. The compute nodes are grouped in pairs of racks with an aisle in the middle. High-speed connection cables connect the racks with overhead cable trays. The cool air from the cooling units is pumped into the computer room from a sub-floor through perforated floor tiles. The CPU cooling fans draw cool air from the floor tiles, which run along the outside length of each rack, and eject warm air into the center isle between the racks. This warm air is eventually drawn into the cooling units located near the walls of the room. One major concern is that the hot air ejected to the middle isle might recirculate back into the cool rack side and cause thermal short-cycling. The simulations analyzed and addressed the following important elements of the computer room: 1) High-temperature build-up in certain regions of the room; 2) Areas of low air circulation in the room; 3) Potential short-cycling of the computer rack cooling system; 4) Effectiveness of the perforated cooling floor tiles; 5) Effect of changes in various aspects of the cooling units. Detailed flow visualization is performed to show temperature distribution, air-flow streamlines and velocities in the computer room.
Subsurface Hybrid Power Options for Oil & Gas Production at Deep Ocean Sites
DOE Office of Scientific and Technical Information (OSTI.GOV)
Farmer, J C; Haut, R; Jahn, G
2010-02-19
An investment in deep-sea (deep-ocean) hybrid power systems may enable certain off-shore oil and gas exploration and production. Advanced deep-ocean drilling and production operations, locally powered, may provide commercial access to oil and gas reserves otherwise inaccessible. Further, subsea generation of electrical power has the potential of featuring a low carbon output resulting in improved environmental conditions. Such technology therefore, enhances the energy security of the United States in a green and environmentally friendly manner. The objective of this study is to evaluate alternatives and recommend equipment to develop into hybrid energy conversion and storage systems for deep ocean operations.more » Such power systems will be located on the ocean floor and will be used to power offshore oil and gas exploration and production operations. Such power systems will be located on the oceans floor, and will be used to supply oil and gas exploration activities, as well as drilling operations required to harvest petroleum reserves. The following conceptual hybrid systems have been identified as candidates for powering sub-surface oil and gas production operations: (1) PWR = Pressurized-Water Nuclear Reactor + Lead-Acid Battery; (2) FC1 = Line for Surface O{sub 2} + Well Head Gas + Reformer + PEMFC + Lead-Acid & Li-Ion Batteries; (3) FC2 = Stored O2 + Well Head Gas + Reformer + Fuel Cell + Lead-Acid & Li-Ion Batteries; (4) SV1 = Submersible Vehicle + Stored O{sub 2} + Fuel Cell + Lead-Acid & Li-Ion Batteries; (5) SV2 = Submersible Vehicle + Stored O{sub 2} + Engine or Turbine + Lead-Acid & Li-Ion Batteries; (6) SV3 = Submersible Vehicle + Charge at Docking Station + ZEBRA & Li-Ion Batteries; (7) PWR TEG = PWR + Thermoelectric Generator + Lead-Acid Battery; (8) WELL TEG = Thermoelectric Generator + Well Head Waste Heat + Lead-Acid Battery; (9) GRID = Ocean Floor Electrical Grid + Lead-Acid Battery; and (10) DOC = Deep Ocean Current + Lead-Acid Battery.« less
RDI's Wisdom Way Solar Village Final Report: Includes Utility Bill Analysis of Occupied Homes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robb Aldrich, Steven Winter Associates
2011-07-01
In 2010, Rural Development, Inc. (RDI) completed construction of Wisdom Way Solar Village (WWSV), a community of ten duplexes (20 homes) in Greenfield, MA. RDI was committed to very low energy use from the beginning of the design process throughout construction. Key features include: 1. Careful site plan so that all homes have solar access (for active and passive); 2. Cellulose insulation providing R-40 walls, R-50 ceiling, and R-40 floors; 3. Triple-pane windows; 4. Airtight construction (~0.1 CFM50/ft2 enclosure area); 5. Solar water heating systems with tankless, gas, auxiliary heaters; 6. PV systems (2.8 or 3.4kWSTC); 7. 2-4 bedrooms, 1,100-1,700more » ft2. The design heating loads in the homes were so small that each home is heated with a single, sealed-combustion, natural gas room heater. The cost savings from the simple HVAC systems made possible the tremendous investments in the homes' envelopes. The Consortium for Advanced Residential Buildings (CARB) monitored temperatures and comfort in several homes during the winter of 2009-2010. In the Spring of 2011, CARB obtained utility bill information from 13 occupied homes. Because of efficient lights, appliances, and conscientious home occupants, the energy generated by the solar electric systems exceeded the electric energy used in most homes. Most homes, in fact, had a net credit from the electric utility over the course of a year. On the natural gas side, total gas costs averaged $377 per year (for heating, water heating, cooking, and clothes drying). Total energy costs were even less - $337 per year, including all utility fees. The highest annual energy bill for any home evaluated was $458; the lowest was $171.« less
Zhiyong Cai; Robert J. Ross; Michael O. Hunt; Lawrence A. Soltis
2002-01-01
Evaluation of existing timber structures requires procedures to evaluate in situ structural members and components. This report evaluates the transverse vibration response of laboratory-built floor systems with new and salvaged joists. The objectives were to 1) compare floor system response to individual member response; 2) examine response sensitivity to location of...
Evaluation of conductive concrete for anti-static flooring applications
NASA Astrophysics Data System (ADS)
Yehia, Sherif; Qaddoumi, Nasser; Hassan, Mohamed; Swaked, Bassam
2015-04-01
Static electricity, exchange of electrons, and retention of charge between any two materials due to contact and separation are affected by the condition of the materials being nonconductive or insulated from ground. Several work environments, such as electronics industry, hospitals, offices, and computer rooms all require electro-static discharge (ESD) mitigation. Carpet Tile, Carpet Broadloom, Vinyl Tile, Vinyl sheet, Epoxy and Rubber are examples of existing flooring systems in the market. However, each system has its advantages and limitations. Conductive concrete is a relatively new material technology developed to achieve high electrical conductivity and high mechanical strength. The conductive concrete material can be an economical alternative for these ESD flooring systems. In this paper, the effectiveness of conductive concrete as an anti-static flooring system was evaluated. The initial results indicated that the proposed conductive concrete flooring and ground system met the acceptance criteria stated by ASTM F150.
The image acquisition system design of floor grinder
NASA Astrophysics Data System (ADS)
Wang, Yang-jiang; Liu, Wei; Liu, Hui-qin
2018-01-01
Based on linear CCD, high resolution image real-time acquisition system serves as designing a set of image acquisition system for floor grinder through the calculation of optical imaging system. The entire image acquisition system can collect images of ground before and after the work of the floor grinder, and the data is transmitted through the Bluetooth system to the computer and compared to realize real-time monitoring of its working condition. The system provides technical support for the design of unmanned ground grinders.
Groups and the Entropy Floor: XMM-Newton Observations of Two Groups
NASA Technical Reports Server (NTRS)
Mushotzky, R. F.; Figueroa-Feliciano, E.; Loewenstein, M.; Snowden, S. L.
2002-01-01
Using XMM-Newton spatially resolved X-ray imaging spectroscopy we obtain the temperature, density, entropy, gas mass, and total mass profiles for two groups of galaxies out to approximately 0.3 R(sub vir)(R(sub vir), the virial radius). Our density profiles agree well with those derived previously, and the temperature data are broadly consistent with previous results but are considerably more precise. Both of these groups are at the mass scale of 2x10(exp 13) M(solar mass), but have rather different properties. Both have considerably lower gas mass fractions at r < 0.3 R(sub vir), than the rich clusters. NGC2563, one of the least luminous groups for its X-ray temperature, has a very low gas mass fraction of approximately 0.004 inside 0.1 R(sub vir), which increases with radius. NGC4325, one of the most luminous groups at the same average temperature, has a higher gas mass fraction of 0.02. The entropy profiles and the absolute values of the entropy as a function of virial radius also differ, with NGC4325 having a value of approximately 100 keV cm(exp -2) and NGC2563 a value of approximately 300 keV cm(exp -2) at r approximately 0.1 R(sub vir). For both groups the profiles rise monotonically with radius and there is no sign of an entropy 'floor'. These results are inconsistent with pre-heating scenarios that have been developed to explain a possible entropy floor in groups, but are broadly consistent with models of structure formation that include the effects of heating and/or the cooling of the gas. The total entropy in these systems provides a strong constraint on all models of galaxy and group formation, and on the poorly defined feedback process that controls the transformation of gas into stars and thus the formation of structure in the universe.
Thermal Models of the Ocean Floor: from Wegener to Cerro Prieto
NASA Astrophysics Data System (ADS)
Sclater, J. G.; Negrete-Aranda, R.
2017-12-01
Wegener (1925) argued that hot rock could explain the shallower depths of ridges in the center of the Atlantic Ocean. Hess (1963) proposed that the intrusion of molten rock occurred at a world encircling mid-ocean ridge system. However, he accounted for the elevation of the ridges by the formation of serpentinite and thermal convection. Langseth et al. (1966) provided the major advance by using a 100 km thick plate to argue such a concept could not explain the depth, heat flow versus distance relations. They had the correct model but misinterpreted the data. Reformulating theoretically, McKenzie (1967) created the generally accepted thermal model for the ocean floor. Unfortunately, in attempting to match erroneously low heat flow data, he used a 50 km thick plate. Addition of the effect of water and the realization of the importance of advective flow, enabled various groups to create thermal plate models that accounted for the heat flow and depth age relations. From this came the understanding of hydrothermal circulation in the oceanic crust, the thermal boundary layer concept of the oceanic plate and the realization that all thermal models differed only in the way the different groups had chosen to analyze the data. During the past 40 years many have applied similar concepts to continental margins: (1) Measurement of subsidence of the Atlantic margin, continental stretching and a Time Temperature, Depth and Maturation analysis of continental basins have created the field of Basin Analysis; (2) Changes in heat flow at ocean continent boundaries have determined the position of the transition and (3) In attempting to examine the ocean continent transition process in the northernmost basin of the Gulf of California, Neumann et al (in press) observed conductive heat flow values greater than 0.75 Watts, at a depth of < 150 m, along a 10 km section of a profile across the southern extension of the Cerro Prieto fault. The magnitude of these values overwhelms local environmental effects and indicates a very large thermal output. Their full potential depends upon the amount of advective flow. Whatever the case, these measurements have opened up shallow continental margins as a new area for geothermic investigation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hunn, B. D.; Diamond, S. C.; Bennett, G. A.
1977-10-01
A set of computer programs, called Cal-ERDA, is described that is capable of rapid and detailed analysis of energy consumption in buildings. A new user-oriented input language, named the Building Design Language (BDL), has been written to allow simplified manipulation of the many variables used to describe a building and its operation. This manual provides the user with information necessary to understand in detail the Cal-ERDA set of computer programs. The new computer programs described include: an EXECUTIVE Processor to create computer system control commands; a BDL Processor to analyze input instructions, execute computer system control commands, perform assignments andmore » data retrieval, and control the operation of the LOADS, SYSTEMS, PLANT, ECONOMICS, and REPORT programs; a LOADS analysis program that calculates peak (design) zone and hourly loads and the effect of the ambient weather conditions, the internal occupancy, lighting, and equipment within the building, as well as variations in the size, location, orientation, construction, walls, roofs, floors, fenestrations, attachments (awnings, balconies), and shape of a building; a Heating, Ventilating, and Air-Conditioning (HVAC) SYSTEMS analysis program capable of modeling the operation of HVAC components including fans, coils, economizers, humidifiers, etc.; 16 standard configurations and operated according to various temperature and humidity control schedules. A plant equipment program models the operation of boilers, chillers, electrical generation equipment (diesel or turbines), heat storage apparatus (chilled or heated water), and solar heating and/or cooling systems. An ECONOMIC analysis program calculates life-cycle costs. A REPORT program produces tables of user-selected variables and arranges them according to user-specified formats. A set of WEATHER ANALYSIS programs manipulates, summarizes and plots weather data. Libraries of weather data, schedule data, and building data were prepared.« less
DOE ZERH Case Study: TC Legend Homes, Bellingham Power House, Bellingham, WA
DOE Office of Scientific and Technical Information (OSTI.GOV)
none,
Case study of a DOE 2015 Housing Innovation Award winning custom home in the marine climate that got HERS 34 without PV or HERS -12 with PV, with 6” SIP walls and 10” SIP roof; R-28 ICF around slab, R-20 rigid foam under slab; radiant floor heat and passive design; air-to-water heat pump COP 4.4; HRV; earth tube ventilation; triple-pane windows, 100% LED.
Ip, Kenneth; She, Kaiming; Adeyeye, Kemi
2017-10-18
Recovering heat from waste water discharged from showers to preheat the incoming cold water has been promoted as a cost-effective, energy-efficient, and low-carbon design option which has been included in the UK's Standard Assessment Procedure (SAP) for demonstrating compliance with the Building Regulation for dwellings. Incentivized by its carbon cost-effectiveness, waste water heat exchangers (WWHX) have been selected and incorporated in a newly constructed Sports Pavilion at the University of Brighton in the UK. This £2-m sports development serving several football fields was completed in August 2015 providing eight water- and energy-efficient shower rooms for students, staff, and external organizations. Six of the shower rooms are located on the ground floor and two on the first floor, each fitted with five or six thermostatically controlled shower units. Inline type of WWHX were installed, each consisted of a copper pipe section wound by an external coil of smaller copper pipe through which the cold water would be warmed before entering the shower mixers. Using the installation at Sport Pavilion as the case study, this research aims to evaluate the environmental and financial sustainability of a vertical waste heat recovery device, over a life cycle of 50 years, with comparison to the normal use of a PVC-u pipe. A heat transfer mathematical model representing the system has been developed to inform the development of the methodology for measuring the in-situ thermal performance of individual and multiple use of showers in each changing room. Adopting a system thinking modeling technique, a quasi-dynamic simulation computer model was established enabling the prediction of annual energy consumptions under different shower usage profiles. Data based on the process map and inventory of a functional unit of WWHX were applied to a proprietary assessment software to establish the relevant outputs for the life-cycle environmental impact assessment. Life-cycle cost models were developed and industry price book data were applied. The results indicated that the seasonal thermal effectiveness was over 50% enabling significant energy savings through heat recovery that led to short carbon payback time of less than 2 years to compensate for the additional greenhouse gas emissions associated with the WWHX. However, the life-cycle cost of the WWHX is much higher than using the PVC pipe, even with significant heat recovered under heavy usage, highlighting the need to adopt more economic configurations, such as combining waste water through fewer units, in order to maximize the return on investment and improve the financial viability.
Basking Behavior of Painted Turtles.
ERIC Educational Resources Information Center
Zipko, Stephen J.
1982-01-01
Examines the basking postures of captive eastern painted turtles exposed to two different sources of illumination (white floor lamps and infrared heat lamps) and three types of substrates (sphagnum, rock, wood) and discusses possible ecological and evolutionary significance of these behaviors. (Author/JN)
Ellingson, Roger M.; Gallun, Frederick J.; Bock, Guillaume
2015-01-01
It can be problematic to measure stationary acoustic sound pressure level in any environment when the target level approaches or lies below the minimum measureable sound pressure level of the measurement system itself. This minimum measureable level, referred to as the inherent measurement system noise floor, is generally established by noise emission characteristics of measurement system components such as microphones, preamplifiers, and other system circuitry. In this paper, methods are presented and shown accurate measuring stationary levels within 20 dB above and below this system noise floor. Methodology includes (1) measuring inherent measurement system noise, (2) subtractive energy based, inherent noise adjustment of levels affected by system noise floor, and (3) verifying accuracy of inherent noise adjustment technique. While generalizable to other purposes, the techniques presented here were specifically developed to quantify ambient noise levels in very quiet rooms used to evaluate free-field human hearing thresholds. Results obtained applying the methods to objectively measure and verify the ambient noise level in an extremely quiet room, using various measurement system noise floors and analysis bandwidths, are presented and discussed. The verified results demonstrate the adjustment method can accurately extend measurement range to 20 dB below the measurement system noise floor, and how measurement system frequency bandwidth can affect accuracy of reported noise levels. PMID:25786932
36 CFR 1192.79 - Floors, steps and thresholds.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Light Rail Vehicles and Systems § 1192.79 Floors, steps and thresholds. (a) Floor surfaces on aisles... accommodated shall be slip-resistant. (b) All thresholds and step edges shall have a band of color(s) running... floor, either light-on-dark or dark-on-light. ...
36 CFR 1192.79 - Floors, steps and thresholds.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Light Rail Vehicles and Systems § 1192.79 Floors, steps and thresholds. (a) Floor surfaces on aisles... accommodated shall be slip-resistant. (b) All thresholds and step edges shall have a band of color(s) running... floor, either light-on-dark or dark-on-light. ...
36 CFR 1192.79 - Floors, steps and thresholds.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Light Rail Vehicles and Systems § 1192.79 Floors, steps and thresholds. (a) Floor surfaces on aisles... accommodated shall be slip-resistant. (b) All thresholds and step edges shall have a band of color(s) running... floor, either light-on-dark or dark-on-light. ...
Karcher, D M; Makagon, M M; Fraley, G S; Fraley, S M; Lilburn, M S
2013-03-01
Commercial poultry production management practices have been under increased public scrutiny driven by concerns for food safety and animal welfare. Within the United States, wood shavings and raised plastic floors are common flooring systems used in duck production. It is intuitive that each flooring type would present different management challenges influencing physical characteristics of growing ducks. This study evaluated the relationship between flooring type and duck condition during the winter. Random samples of 20 ducks from 5 predetermined areas (n = 100) were examined in commercial duck houses (n = 9, litter; n = 11, raised plastic slats). Ducks were assessed at 7, 21, and 32 d of age for eye, nostril, and feather cleanliness, feather and foot pad quality, and gait. The data were analyzed to determine the proportion of ducks with a given score. In both housing types, the proportion of 0 scores for foot pad quality improved during the production cycle (P < 0.0001). Feather hygiene declined with age in ducks reared on litter flooring, whereas ducks reared on slatted flooring had cleaner feathers at d 32 (P < 0.011). With the exception of foot pad scores, the majority of ducks had no detectable problems for any single trait. The only main effect due to flooring pertained to feather quality with the proportion of ducks having a 0 or 1 score greater in litter flooring systems than slats (P < 0.05). Overall, the condition of ducks reared, regardless of flooring system, was considered to be good.
Factors influencing indoor PM2.5 concentration in rural houses of northern China
NASA Astrophysics Data System (ADS)
Zhang, Xueyan; Chen, Bin
2018-02-01
In traditional houses in rural areas of Northern China, most traditional heating systems, heated by mini-stove in the kitchen, usually take agricultural residues as fuels resources. Besides, burning cave under the ground-floor of a rural house is also widely used. The higher PM2.5 concentration is crisis for human health. In this study, PM2.5 concentration, temperature, relative humidity inside and outside the houses have been measured, moreover the factors impact on I/O rate coefficient has been discussed. The results show that the I/O rate coefficient in the evening is 2.5 times greater than the I/O rate coefficient in the daytime. I/O rate coefficient of PM2.5 concentration is positive related to air temperature difference between indoor and outdoor. In addition, the impact of outdoor wind speed and predominant wind direction on the PM2.5 emission has been studied.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
This appendix summarizes building characteristics used to determine heating and cooling loads for each of the five building types in each of the four regions. For the selected five buildings, the following data are attached: new and existing construction characteristics; new and existing construction thermal resistance; floor plan and elevation; people load schedule; lighting load schedule; appliance load schedule; ventilation schedule; and hot water use schedule. For the five building types (single family, apartment buildings, commercial buildings, office buildings, and schools), data are compiled in 10 appendices. These are Building Characteristics; Alternate Energy Sources and Energy Conservation Techniques Description, Costs,more » Fuel Price Scenarios; Life Cycle Cost Model; Simulation Models; Solar Heating/Cooling System; Condensed Weather; Single and Multi-Family Dwelling Characteristics and Energy Conservation Techniques; Mixed Strategies for Energy Conservation and Alternative Energy Utilization in Buildings. An extensive bibliography is given in the final appendix. (MCW)« less
Sloto, Ronald A.
1997-01-01
A suite of borehole geophysical logs and heat-pulse-flowmeter measurements run in the former production well at the John Wagner and Sons, Inc. plant indicate two zones of borehole flow. In the upper part of the well, water enters the borehole through a fracture at 90 ft (feet) below floor level, moves upward, and exits the borehole through a fracture at 72 ft below floor level. Water also enters the borehole through fractures at 205-213, 235, and 357 ft below floor level; moves downward; and exits the borehole through fractures at 450-459, 468-470, and 483-490 ft below floor level. Five zones were selected for aquifer-isolation (packer) tests on the basis of borehole geophysical logs. The zones were isolated using a straddle-packer assembly. The lowermost three zones (below 248, 223 to 248, and 198 to 223 ft below floor level) were hydraulically isolated from zones above and below. Specific capacities were 0.12, 0.034, and 0.15 gallons per minute per foot, respectively. The hydrograph from zone 2 (223 to 248 ft below floor level) showed interference from a nearby pumping well. For the upper two zones (81 to 106 and 57 to 81 ft below floor level), similar drawdowns in the isolated zone and the zones above and below the isolated zone indicate that these fractures are hydraulically connected outside the borehole in the unconfined part of the Stockton Formation. The specific capacity of zones 4 and 5 are similar—0.82 and 0.61, respectively.
Walking beam furnace well-way slot covers at Rouge Steel
DOE Office of Scientific and Technical Information (OSTI.GOV)
Campbell, F. Jr.; Meinzinger, A.D.; Faust, C.H.
1993-07-01
Rouge Steel's 68-in. hot strip mill is served by three walking beam slab reheat furnaces. The first two were commissioned in 1974 and the third was installed in 1980. During the period 1979 to 1981, an intensive plant-wide energy management program to reduce energy consumption was undertaken. A major part of that program involved a comprehensive upgrading of refractory and insulation systems utilized in the walking beam reheat furnaces. A durable system for reducing heat losses through the well-way floor openings associated with walking beam slab reheat furnaces has, in addition to 4 to 5% savings in fuel consumption, reducedmore » maintenance costs. Payback is achieved in four to five months.« less
Best, R
1981-01-01
If the arsonist who set fire to the fourth floor of this hospital intended to destroy the whole hospital, his plans were foiled by the hospital's lifesafety systems and the quick action of the hospital staff. Corridor smoke detectors activated the building fire alarm system, notified the hospital fire brigade and staff, notified the fire department, and closed the corridor smokestop doors. Members of the staff immediately closed the doors to all patient rooms in the area of the fire that were exposed to smoke and heat, and then began evacuating patients from the area. There were no fatalities in this fire. Although this fire is four years old, we think it is worth studying for its contrasts with Mississauga.
36 CFR § 1192.79 - Floors, steps and thresholds.
Code of Federal Regulations, 2013 CFR
2013-07-01
... VEHICLES Light Rail Vehicles and Systems § 1192.79 Floors, steps and thresholds. (a) Floor surfaces on... accommodated shall be slip-resistant. (b) All thresholds and step edges shall have a band of color(s) running... floor, either light-on-dark or dark-on-light. ...
7. INTERIOR OF SECONDFLOOR MAIN SECTION OF BUILDING 321. VIEW ...
7. INTERIOR OF SECOND-FLOOR MAIN SECTION OF BUILDING 321. VIEW TO WEST. - Rocky Mountain Arsenal, Boiler Plant-Central Gas Heat Plant, 1022 feet South of December Seventh Avenue; 525 feet West of D Street, Commerce City, Adams County, CO
4. INTERIOR OF FIRSTFLOOR WEST SECTION OF BUILDING 321. VIEW ...
4. INTERIOR OF FIRST-FLOOR WEST SECTION OF BUILDING 321. VIEW TO NORTH. - Rocky Mountain Arsenal, Boiler Plant-Central Gas Heat Plant, 1022 feet South of December Seventh Avenue; 525 feet West of D Street, Commerce City, Adams County, CO
6. INTERIOR OF THIRDFLOOR MAIN SECTION OF BUILDING 321. VIEW ...
6. INTERIOR OF THIRD-FLOOR MAIN SECTION OF BUILDING 321. VIEW TO WEST. - Rocky Mountain Arsenal, Boiler Plant-Central Gas Heat Plant, 1022 feet South of December Seventh Avenue; 525 feet West of D Street, Commerce City, Adams County, CO
9 CFR 590.548 - Drying, blending, packaging, and heat treatment rooms and facilities.
Code of Federal Regulations, 2010 CFR
2010-01-01
... rooms shall be well-lighted and have ceilings and walls of a tile surface, enamel paint, or other water-resistant material. (1) The floors shall be free from cracks or rough surfaces where water or dirt could...
Package Up Your Troubles--An Introduction to Package Libraries
ERIC Educational Resources Information Center
Frank, Colin
1978-01-01
Discusses a "package deal" library--a prefabricated building including interior furnishing--in terms of costs, fitness for purpose, and interior design, i.e., shelving, flooring, heating, lighting, and humidity. Advantages and disadvantages of the package library are also considered. (Author/MBR)
ERIC Educational Resources Information Center
AIA Journal, 1981
1981-01-01
At the Telluride (Colorado) school, the classroom wing was outfitted with a thick floor slab and a greenhouse space where heat is stored in waterfilled tubes. The gymnasium's southwestern wall was transformed into a Trombe wall by applying 2,000 square feet of glazing. (Author/MLF)
Pulsations, interpulsations, and sea-floor spreading.
NASA Technical Reports Server (NTRS)
Pessagno, E. A., Jr.
1973-01-01
It is postulated that worldwide transgressions (pulsations) and regressions (interpulsations) through the course of geologic time are related to the elevation and subsidence of oceanic ridge systems and to sea-floor spreading. Two multiple working hypotheses are advanced to explain major transgressions and regressions and the elevation and subsidence of oceanic ridge systems. One hypothesis interrelates the sea-floor spreading hypothesis to the hypothesis of sub-Mohorovicic serpentinization. The second hypothesis relates the sea-floor spreading hypothesis to a hypothesis involving thermal expansion and contraction.
Razak, A A; Harrison, A
1997-04-01
Dimensional accuracy of a composite inlay restoration is important to ensure an accurate fit and to minimize cementation stresses. A method was developed to measure dimensional accuracy and stability of a composite inlay. A standard Class II (MOD) inlay cavity stainless steel mold was made with six circular indentations placed on the occlusal floor of the cavity and four indentations on each gingival floor to act as datum points in the measurement of linear polymerization shrinkage. The inlay restorations were prepared from an inlay-onlay composite material of different filler contents (50%, 65%, and 79% by weight). For each filler content group, three curing methods were used: light curing only, light curing and heat curing at 100 degrees C for 5 minutes, and light curing and heat curing at 100 degrees C for 5 minutes and then storage in distilled water for 7 days. The accuracy of the MOD inlays was determined by measuring the shrinkage of the restoration on the occlusal floor areas and the gingival seats. The results demonstrated an inverse linear relationship between filler content and polymerization shrinkage. There was a tendency for the light-curing and heat-curing method to show an increase in polymerization shrinkage. An expansion was recorded between the mesial and distal boxes when the specimens were soaked in water for 7 days. This study suggested that the inlay mold limits the physical shrinkage that can occur between the mesial and distal axial walls of the inlay restoration because the inlay cannot shrink to a smaller dimension than the mold. Water sorption then causes hygroscopic expansion, which enlarges the distance between the mesial and distal walls.
36 CFR 1192.79 - Floors, steps and thresholds.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Floors, steps and thresholds... Light Rail Vehicles and Systems § 1192.79 Floors, steps and thresholds. (a) Floor surfaces on aisles, step treads, places for standees, and areas where wheelchair and mobility aid users are to be...
49 CFR 38.79 - Floors, steps and thresholds.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 1 2010-10-01 2010-10-01 false Floors, steps and thresholds. 38.79 Section 38.79... SPECIFICATIONS FOR TRANSPORTATION VEHICLES Light Rail Vehicles and Systems § 38.79 Floors, steps and thresholds. (a) Floor surfaces on aisles, step treads, places for standees, and areas where wheelchair and...
49 CFR 38.99 - Floors, steps and thresholds.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 1 2010-10-01 2010-10-01 false Floors, steps and thresholds. 38.99 Section 38.99... SPECIFICATIONS FOR TRANSPORTATION VEHICLES Commuter Rail Cars and Systems § 38.99 Floors, steps and thresholds. (a) Floor surfaces on aisles, step treads, places for standees, and areas where wheelchair and...
49 CFR 38.117 - Floors, steps and thresholds.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 1 2010-10-01 2010-10-01 false Floors, steps and thresholds. 38.117 Section 38...) ACCESSIBILITY SPECIFICATIONS FOR TRANSPORTATION VEHICLES Intercity Rail Cars and Systems § 38.117 Floors, steps and thresholds. (a) Floor surfaces on aisles, step treads and areas where wheelchair and mobility aid...
Potential for a significant deep basin geothermal system in Tintic Valley, Utah
NASA Astrophysics Data System (ADS)
Hardwick, C.; Kirby, S.
2014-12-01
The combination of regionally high heat flow, deep basins, and permeable reservoir rocks in the eastern Great Basin may yield substantial new geothermal resources. We explore a deep sedimentary basin geothermal prospect beneath Tintic Valley in central Utah using new 2D and 3D models coupled with existing estimates of heat flow, geothermometry, and shallow hydrologic data. Tintic Valley is a sediment-filled basin bounded to the east and west by bedrock mountain ranges where heat-flow values vary from 85 to over 240 mW/m2. Based on modeling of new and existing gravity data, a prominent 30 mGal low indicates basin fill thickness may exceed 2 km. The insulating effect of relatively low thermal conductivity basin fill in Tintic Valley, combined with typical Great Basin heat flow, predict temperatures greater than 150 °C at 3 km depth. The potential reservoir beneath the basin fill is comprised of Paleozoic carbonate and clastic rocks. The hydrology of the Tintic Valley is characterized by a shallow, cool groundwater system that recharges along the upper reaches of the basin and discharges along the valley axis and to a series of wells. The east mountain block is warm and dry, with groundwater levels just above the basin floor and temperatures >50 °C at depth. The west mountain block contains a shallow, cool meteoric groundwater system. Fluid temperatures over 50 °C are sufficient for direct-use applications, such as greenhouses and aquaculture, while temperatures exceeding 140°C are suitable for binary geothermal power plants. The geologic setting and regionally high heat flow in Tintic Valley suggest a geothermal resource capable of supporting direct-use geothermal applications and binary power production could be present.
2012-06-28
CAPE CANAVERAL, Fla. - The transportation canister holding the Orion crew module is lowered onto the floor of the Operations and Checkout Building high bay at NASA's Kennedy Space Center in Florida. Slated for Exploration Flight Test-1, an uncrewed mission planned for 2014, the capsule will travel farther into space than any human spacecraft has gone in more than 40 years. NASA's Michoud Assembly Facility in New Orleans built the crew module pressure vessel. The Orion production team will prepare the module for flight by installing heat-shielding thermal protection systems, avionics and other subsystems. For more information, visit http://www.nasa.gov/orion. Photo credit: NASA/Charisse Nahser
Fraley, S M; Fraley, G S; Karcher, D M; Makagon, M M; Lilburn, M S
2013-07-01
The management and well-being of commercial Pekin ducks has been studied in the European Union where straw is the predominant litter source. In the United States, however, the most prevalent litter is wood shavings, with a recent trend toward using plastic slatted flooring. A previous study in the United States evaluated the relationship between flooring type (litter, slats) and duck condition during winter months and found very few differences between the 2 in terms of overall duck condition. The purpose of the current study was to reevaluate the 2 flooring systems during the summer months to determine if seasonal differences would interact with flooring type to have an impact on duck condition. Eighteen commercial barns that produce Pekin ducks for Maple Leaf Farms Inc. (Leesburg, IN), located in northern Indiana and southern Wisconsin (n = 9 litter; n = 9 raised slatted floor), were used for this study. Twenty ducks were randomly selected from 5 predetermined areas within each house (n = 100 total) and scored for eye condition, nostril and feather cleanliness, and feather and foot pad quality at 7, 21, and 32 d of age. Environmental data, including carbon monoxide, ammonia, RH, and temperature, were also obtained at each collection day. The only statistical differences in body condition occurred at 7 d; there were more ducks with clear eyes and eye rings on the litter flooring, whereas average nostril scores were better on the plastic slatted floors. Live weight, weight gain per day, flock mortality, and condemnations at the plant were collected, and the only statistical difference was a higher gain per day for ducks reared on slatted floors compared with litter (P < 0.05). There were no differences between flooring systems in the environmental parameters measured within the barns. In summary, there were very few differences between the litter and slatted flooring systems, indicating that there may not be clear advantages for one particular flooring system over the other from the point of view of duck well-being and production.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
Designing a superinsulated home has many benefits including improved comfort, reduced exterior noise penetration, lower energy bills, and the ability to withstand power and fuel outages under much more comfortable conditions than a typical home. Extremely low heating and cooling loads equate to much smaller HVAC equipment than conventionally required. Sizing the mechanical system to these much lower loads reduces first costs and the size of the distribution system needed. While these homes aren't necessarily constructed with excessive mass in the form of concrete floors and walls, the amount of insulation and the increase in the thickness of the buildingmore » envelope can lead to a mass effect, resulting in the structures ability to store much more heat than a code built home. This results in a very low thermal inertia making the building much less sensitive to drastic temperature swings thereby decreasing the peak heating load demand. Alternative methods that take this inertia into account along with solar and internal gains result in smaller more appropriate design loads than those calculated using Manual J version 8. During the winter of 2013/2014, CARB monitored the energy use of three homes in climate zone 6 in an attempt to evaluate the accuracy of two different mechanical system sizing methods for low load homes. Based on the results, it is recommended that internal and solar gains be included and some credit for thermal inertia be used in sizing calculations for superinsulated homes.« less
5. INTERIOR OF SECONDAND THIRDFLOOR MAIN SECTION OF BUILDING 321. ...
5. INTERIOR OF SECOND-AND THIRD-FLOOR MAIN SECTION OF BUILDING 321. VIEW TO WEST. - Rocky Mountain Arsenal, Boiler Plant-Central Gas Heat Plant, 1022 feet South of December Seventh Avenue; 525 feet West of D Street, Commerce City, Adams County, CO
Winters, William J.; Lorenson, T.D.; Paull, Charles K.
2007-01-01
The northern Gulf of Mexico contains many documented gas hydrate deposits near the sea floor. Although gas hydrate often is present in shallow subbottom sediment, the extent of hydrate occurrence deeper than 10 meters below sea floor in basins away from vents and other surface expressions is unknown. We obtained giant piston cores, box cores, and gravity cores and performed heat-flow analyses to study these shallow gas hydrate deposits aboard the RV Marion Dufresne in July 2002. This report presents measurements and interpretations from that cruise. Our results confirm the presence of gas hydrate in vent-related sediments near the sea bed. The presence of gas hydrate near the vents is governed by the complex interaction of regional and local factors, including heat flow, fluid flow, faults, pore-water salinity, gas concentrations, and sediment properties. However, conditions appropriate for extensive gas hydrate formation were not found away from the vents.
Energy harvesting from wood floor vibration using a piezoelectric generator
Jiangming Kan; Robert J. Ross; Xiping Wang; Wenbin Li
2017-01-01
Vibration can occur in wood floor systems as a consequence of a variety of human activities, ranging from common daily movements associated with individuals living in homes to high-intensity activities associated with sporting events that are held in large sports arenas. For example, the potential for harvesting energy from a wooden floor system in public buildings...
NASA Technical Reports Server (NTRS)
Everhart, Joel L.
2008-01-01
Impact and debris damage to the Space Shuttle Orbiter Thermal Protection System tiles is a random phenomenon, occurring at random locations on the vehicle surface, resulting in random geometrical shapes that are exposed to a definable range of surface flow conditions. In response to the 2003 Final Report of the Columbia Accident Investigation Board, wind tunnel aeroheating experiments approximating a wide range of possible damage scenarios covering both open and closed cavity flow conditions were systematically tested in hypersonic ground based facilities. These data were analyzed and engineering assessment tools for damage-induced fully-laminar heating were developed and exercised on orbit. These tools provide bounding approximations for the damaged-surface heating environment. This paper presents a further analysis of the baseline, zero-pressure-gradient, idealized, rectangular-geometry cavity heating data, yielding new laminar correlations for the floor-averaged heating, peak cavity endwall heating, and the downstream decay rate. Correlation parameters are derived in terms of cavity geometry and local flow conditions. Prediction Limit Uncertainty values are provided at the 95%, 99% and 99.9% levels of significance. Non-baseline conditions, including non-rectangular geometries and flows with known pressure gradients, are used to assess the range of applicability of the new correlations. All data variations fall within the 99% Prediction Limit Uncertainty bounds. Importantly, both open-flow and closed-flow cavity heating are combined into a single-curve parameterization of the heating predictions, and provide a concise mathematical model of the laminar cavity heating flow field with known uncertainty.
36 CFR 1192.99 - Floors, steps and thresholds.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Floors, steps and thresholds... Commuter Rail Cars and Systems § 1192.99 Floors, steps and thresholds. (a) Floor surfaces on aisles, step... shall be slip-resistant. (b) All thresholds and step edges shall have a band of color(s) running the...
Lachance, Chantelle C; Korall, Alexandra M B; Russell, Colin M; Feldman, Fabio; Robinovitch, Stephen N; Mackey, Dawn C
2016-09-01
The aim of this study was to investigate the effects of flooring type and resident weight on external hand forces required to push floor-based lifts in long-term care (LTC). Novel compliant flooring is designed to reduce fall-related injuries among LTC residents but may increase forces required for staff to perform pushing tasks. A motorized lift may offset the effect of flooring on push forces. Fourteen female LTC staff performed straight-line pushes with two floor-based lifts (conventional, motor driven) loaded with passengers of average and 90th-percentile resident weights over four flooring systems (concrete+vinyl, compliant+vinyl, concrete+carpet, compliant+carpet). Initial and sustained push forces were measured by a handlebar-mounted triaxial load cell and compared to participant-specific tolerance limits. Participants rated pushing difficulty. Novel compliant flooring increased initial and sustained push forces and subjective ratings compared to concrete flooring. Compared to the conventional lift, the motor-driven lift substantially reduced initial and sustained push forces and perceived difficulty of pushing for all four floors and both resident weights. Participants exerted forces above published tolerance limits only when using the conventional lift on the carpet conditions (concrete+carpet, compliant+carpet). With the motor-driven lift only, resident weight did not affect push forces. Novel compliant flooring increased linear push forces generated by LTC staff using floor-based lifts, but forces did not exceed tolerance limits when pushing over compliant+vinyl. The motor-driven lift substantially reduced push forces compared to the conventional lift. Results may help to address risk of work-related musculoskeletal injury, especially in locations with novel compliant flooring. © 2016, Human Factors and Ergonomics Society.
[Analysis of ancient literature on baliao points for pelvic floor diseases].
Liu, Hairong; Zhang, Jianbin
2016-12-12
The relationship between baliao points and pelvis floor diseases was explored based on the ancient literature review on these acupoints' targeted diseases. It is considered that baliao points are applied to treat various pelvis floor diseases and symptoms of different systems. Each point has similar function but with unique feature. Shangliao (BL 31) is mainly used to treat gynecologic diseases;Ciliao (BL 32) and Zhongliao (BL 33),urologic system and reproductive system diseases;Zhongliao (BL 33) and Xialiao (BL 34),reproductive system and anorectal system diseases.
Lachance, Chantelle C; Jurkowski, Michal P; Dymarz, Ania C; Robinovitch, Stephen N; Feldman, Fabio; Laing, Andrew C; Mackey, Dawn C
2017-01-01
Compliant flooring, broadly defined as flooring systems or floor coverings with some level of shock absorbency, may reduce the incidence and severity of fall-related injuries in older adults; however, a lack of synthesized evidence may be limiting widespread uptake. Informed by the Arksey and O'Malley framework and guided by a Research Advisory Panel of knowledge users, we conducted a scoping review to answer: what is presented about the biomechanical efficacy, clinical effectiveness, cost-effectiveness, and workplace safety associated with compliant flooring systems that aim to prevent fall-related injuries in healthcare settings? We searched academic and grey literature databases. Any record that discussed a compliant flooring system and at least one of biomechanical efficacy, clinical effectiveness, cost-effectiveness, or workplace safety was eligible for inclusion. Two independent reviewers screened and abstracted records, charted data, and summarized results. After screening 3611 titles and abstracts and 166 full-text articles, we included 84 records plus 56 companion (supplementary) reports. Biomechanical efficacy records (n = 50) demonstrate compliant flooring can reduce fall-related impact forces with minimal effects on standing and walking balance. Clinical effectiveness records (n = 20) suggest that compliant flooring may reduce injuries, but may increase risk for falls. Preliminary evidence suggests that compliant flooring may be a cost-effective strategy (n = 12), but may also result in increased physical demands for healthcare workers (n = 17). In summary, compliant flooring is a promising strategy for preventing fall-related injuries from a biomechanical perspective. Additional research is warranted to confirm whether compliant flooring (i) prevents fall-related injuries in real-world settings, (ii) is a cost-effective intervention strategy, and (iii) can be installed without negatively impacting workplace safety. Avenues for future research are provided, which will help to determine whether compliant flooring is recommended in healthcare environments.
Jurkowski, Michal P.; Dymarz, Ania C.; Robinovitch, Stephen N.; Feldman, Fabio; Laing, Andrew C.; Mackey, Dawn C.
2017-01-01
Background Compliant flooring, broadly defined as flooring systems or floor coverings with some level of shock absorbency, may reduce the incidence and severity of fall-related injuries in older adults; however, a lack of synthesized evidence may be limiting widespread uptake. Methods Informed by the Arksey and O’Malley framework and guided by a Research Advisory Panel of knowledge users, we conducted a scoping review to answer: what is presented about the biomechanical efficacy, clinical effectiveness, cost-effectiveness, and workplace safety associated with compliant flooring systems that aim to prevent fall-related injuries in healthcare settings? We searched academic and grey literature databases. Any record that discussed a compliant flooring system and at least one of biomechanical efficacy, clinical effectiveness, cost-effectiveness, or workplace safety was eligible for inclusion. Two independent reviewers screened and abstracted records, charted data, and summarized results. Results After screening 3611 titles and abstracts and 166 full-text articles, we included 84 records plus 56 companion (supplementary) reports. Biomechanical efficacy records (n = 50) demonstrate compliant flooring can reduce fall-related impact forces with minimal effects on standing and walking balance. Clinical effectiveness records (n = 20) suggest that compliant flooring may reduce injuries, but may increase risk for falls. Preliminary evidence suggests that compliant flooring may be a cost-effective strategy (n = 12), but may also result in increased physical demands for healthcare workers (n = 17). Conclusions In summary, compliant flooring is a promising strategy for preventing fall-related injuries from a biomechanical perspective. Additional research is warranted to confirm whether compliant flooring (i) prevents fall-related injuries in real-world settings, (ii) is a cost-effective intervention strategy, and (iii) can be installed without negatively impacting workplace safety. Avenues for future research are provided, which will help to determine whether compliant flooring is recommended in healthcare environments. PMID:28166265
NASA Astrophysics Data System (ADS)
Su, Rose Mary; Tocci, Gregory
2005-09-01
The measurement of the Impact Insulation Class (IIC) rating of any floor/ceiling construction requires the use of a certified laboratory space. In a recent investigation into the IIC rating of a new floor system, several tests were conducted in a certified laboratory. In many tests, the IIC rating was controlled by the 100-Hz 1/3-octave frequency band, despite changes in the floor/ceiling construction. The base floor/ceiling construction included a wood structural floor on open-web wood joists and a GWB ceiling below. This paper will investigate the possibility that room resonances influenced the IIC ratings of the several floor systems tested. These data will be compared with IIC data collected for the same floor construction with the GWB ceiling removed. The removal of the GWB ceiling increased the receiver room volume and exposed the glass fiber insulation to the receiver room, thus eliminating the control of the 100-Hz 1/3-octave band over the IIC rating.
Fire and Heat Spreading Model Based on Cellular Automata Theory
NASA Astrophysics Data System (ADS)
Samartsev, A. A.; Rezchikov, A. F.; Kushnikov, V. A.; Ivashchenko, V. A.; Bogomolov, A. S.; Filimonyuk, L. Yu; Dolinina, O. N.; Kushnikov, O. V.; Shulga, T. E.; Tverdokhlebov, V. A.; Fominykh, D. S.
2018-05-01
The distinctive feature of the proposed fire and heat spreading model in premises is the reduction of the computational complexity due to the use of the theory of cellular automata with probability rules of behavior. The possibilities and prospects of using this model in practice are noted. The proposed model has a simple mechanism of integration with agent-based evacuation models. The joint use of these models could improve floor plans and reduce the time of evacuation from premises during fires.
2012-06-01
insulation, boiler, holding tank and duct coverings, floor tiles , window caulking/glazing, and corrugated building siding. The asbestos insulation and...facility, with the Bulk Fuel Storage area and the golf course located between them. BOMARC is located several miles from the proposed solar sites...Architectural Resources The Central Heat Plant was constructed in 1956. It is a flat- roofed building originally rectangular in form, and is now L-shaped. The
DOE Office of Scientific and Technical Information (OSTI.GOV)
none,
This case study describes a DOE Zero Energy Ready Home in Seattle, WA, that scored HERS 42 without PV and a -1 with PV. This 3,192 ft2 custom home has 6-inch SIP walls, a 12-inch SIP roof, an R-28 ICF-insulated foundation slab edge with R-20 rigid foam under the slab; an air-to-water heat pump plus radiant floor heat; 100% LED lighting; filtered-fan-powered fresh air intake; triple-pane windows, 9.7 kWh PV for electric car charging station.
77 FR 76542 - Millstone Power Station, Unit 2; Exemption
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-28
... cable insulation and limited floor based combustibles. The licensee also stated that two of the fire... are provided with ionization smoke detectors. The licensee stated that the smoke and heat detection... combustible loading that predominantly consists of cable insulation and that potential ignition sources for...
24 CFR 3280.4 - Incorporation by reference.
Code of Federal Regulations, 2011 CFR
2011-04-01
... Floor, Arlington, VA 22209-2403 ASCE—American Society of Civil Engineers, 345 East 47th Street, New York, New York 10017-2398 ASHRAE—American Society of Heating, Refrigeration and Air Conditioning Engineers, 1791 Tulle Circle, NE., Atlanta, Georgia 30329 ASME—American Society of Mechanical Engineers, 345 East...
41 CFR 102-80.145 - What is meant by “flashover”?
Code of Federal Regulations, 2010 CFR
2010-07-01
...”? Flashover means fire conditions in a confined area where the upper gas layer temperature reaches 600 °C (1100 °F) and the heat flux at floor level exceeds 20 kW/m2 (1.8 Btu/ft2/sec). Reasonable Worst Case...
41 CFR 102-80.145 - What is meant by “flashover”?
Code of Federal Regulations, 2011 CFR
2011-01-01
...”? Flashover means fire conditions in a confined area where the upper gas layer temperature reaches 600 °C (1100 °F) and the heat flux at floor level exceeds 20 kW/m2 (1.8 Btu/ft2/sec). Reasonable Worst Case...
The Marcraft floor-leveling system for urban rehabilitation
David G. Martens; E. Paul Craft
1967-01-01
A speedy and efficient system has been developed for installing wooden screeds that can be used as a base for laying a level new floor over an old sagging floor. The screeds are held in position by means of a new leveling device, and rigid urethane foam is sprayed under the screeds to hold them permanently in a level position.
Zhiyong Cai; Michael O. Hunt; Robert J. Ross; Lawrence A. Soltis
1999-01-01
To date, there is no standard method for evaluating the structural integrity of wood floor systems using nondestructive techniques. Current methods of examination and assessment are often subjective and therefore tend to yield imprecise or variable results. For this reason, estimates of allowable wood floor loads are often conservative. The assignment of conservatively...
36 CFR 1192.117 - Floors, steps and thresholds.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Floors, steps and thresholds... Intercity Rail Cars and Systems § 1192.117 Floors, steps and thresholds. (a) Floor surfaces on aisles, step.... (b) All step edges and thresholds shall have a band of color(s) running the full width of the step or...
Effect of different flooring systems on claw conformation of dairy cows.
Telezhenko, E; Bergsten, C; Magnusson, M; Nilsson, C
2009-06-01
The effect of different flooring surfaces in walking and standing areas on claw conformation, claw horn growth, and wear was studied in 2 experiments during 2 consecutive housing seasons in a research dairy herd of 170 cows. In experiment 1, the flooring systems tested were solid rubber mats, mastic asphalt with and without rubber-matted feed-stalls, and aged concrete slats. In experiment 2, slatted concrete flooring was compared with slatted rubber flooring. The cows were introduced to the respective flooring systems in early lactation and their claws were trimmed before the exposure period. Toe length, toe angle, sole concavity, and claw width, as well as claw growth and wear rates were recorded for lateral and medial claws of the left hind limb. Claw asymmetry calculations were based on these claw measurements and on differences in sole protrusion between lateral and medial soles. Asphalt floors caused shorter toe length and steeper toe angle. They also increased wear on rear claws (5.30 +/- 0.31 and 5.95 +/- 0.33 mm/mo for lateral and medial claw, respectively; LSM +/- SE) and horn growth rate (5.12 +/- 0.36 and 5.83 +/- 0.31 mm/mo of lateral and medial claws, respectively). Rubber mats instead of asphalt in walking areas reduced wear (1.36 +/- 0.19 and 2.02 +/- 0.20 mm/mo for lateral and medial claw, respectively) and claw growth (3.83 +/- 0.23 and 3.94 +/- 0.17 mm/mo for lateral and medial claw, respectively). Rubber-matted feed-stalls together with asphalt walkways decreased claw wear (3.29 +/- 0.31 and 4.10 +/- 0.32 mm/mo for lateral and medial claw, respectively). The concavity of claw soles was reduced on asphalt, especially in the lateral rear claws. Rubber matting in feed-stalls prevented loss of sole concavity compared with asphalt. Claw asymmetry did not differ between flooring systems. While different access to abrasive flooring affected claw conformation, there was no evidence that flooring system influenced the disproportion between lateral and medial claws.
Deflections of Uniformly Loaded Floors. A Beam-Spring Analog.
1984-09-01
joist floor systems have long been analyzed and Recently, the FEAFLO program was used to predict the designed by assuming that the joists act as...simple beams in behavior of floors constructed with joists whose properties carrying the design load. This simple method neglects many were determined in...uniform joist properties.) Designated N-3 for the floor with ’. nailed sheathing and G-3 for the floor with the sheathing 02 attached by means of a rigid
25. VIEW FOURTH FLOOR, ELEVATOR PULLEY TRANSPORT SYSTEM, LOOKING AT ...
25. VIEW FOURTH FLOOR, ELEVATOR PULLEY TRANSPORT SYSTEM, LOOKING AT TOP MAIN WOOD AND STEEL BEAM SUPPORT SYSTEM, NORTHWEST - Bates Manufacturing Company, Storehouse, Northeast corner of Chestnut Street & Hines Alley, Lewiston, Androscoggin County, ME
Attic floor; view west showing roof structural system North ...
Attic floor; view west showing roof structural system - North Philadelphia Station, 2900 North Broad Street, on northwest corner of Broad Street & Glenwood Avenue, Philadelphia, Philadelphia County, PA
Localized Electrical Heating System for Various Types of Buildings
NASA Astrophysics Data System (ADS)
Shelehov, I. Y.; Smirnov, E. I.; Inozemsev, V. P.
2017-11-01
The article presents an overview of the factors determining the establishment of zones with high temperature in industrial, public and administrative buildings. The authors state the task on the improvement of the electric energy use efficiency and cost savings associated with the heating of these buildings by infrared electric heater devices. Materials and methods: The experiments were conducted in a room with the sizes of 3x6 m2 with a ceiling height of 3 m, the concrete floor was covered with laminate, in which increments of 250 mm were drilled and installed the thermocouple. In the process, had used the patented heating element with distributed heating layer. Signals from the thermocouples were recorded by instruments of the firm “ARIES” brand TPM138 with the standard software delivered together with devices (Owen Process Manager). The obtained distributions of the temperature fields were imported into MS Excel. Control voltage, current consumption, power was carried out by the device of firm “ARIES” brand of IMS. The results of the study: the article defines the purpose of the study and carried out the characterization of infrared heaters with various types of heating elements. The authors detail the main parameters of different types of infrared heaters, evaluated its possibility for application in other areas where the need to create areas of increased temperature. Discussion and conclusion: the result of this work it was determined that heating appliances that use patented heating element with distributed heating layer, improve thermal performance and bring you maximum comfort at a much greater distance compared to existing similar devices
1988-05-01
OF EXTRUSION HLSGFLN XRSO ICO-F XTUINPPER PATE CUT-OFF EXTRUSION I I 7 TUMBLE S TUMBLE HEAT &SORT TML I IEC SPANK & PIERCE P A SPANK & PIERCEI IF...implementation, the Walnut Cell will utilize 50% of the "As-Is" floor space. 106 -EGREflSEII HSL 59 i.CUT OFF EXTRUSION 2. SPANK & PIERCE I 3.DEGREASE 4...FEMALE MALE CUT-OFF EXTRUSION I HOUSNG HOUNG I SPANK & PIERCE SPANK & PIERCE I CLEAN I DEG SE I I DEGREASEI I C P P E R PL A TE I HEAT TREAT I HEAT
Energy Efficiency and Sustainability of Different Building Structures in Latvian Climate
NASA Astrophysics Data System (ADS)
Jakovičs, A.; Gendelis, S.; Bandeniece, L.
2015-11-01
Five experimental test buildings have been built in Riga, Latvia. They are identical except external walls for which different mainly regional building materials are used. Calculated U-values of the other walls, floor and ceiling are the same for each test building. Initial moisture influences the relative humidity of indoor air, which can be higher in the initial time period; as a result, heat transmittances are also very different and cause different heating/cooling energy consumption. Overheating risk in summer exists for test buildings with the smallest thermal inertia. Both summer and heating seasons have been analysed and differences between five test houses have been discussed in details.
16 Photocopy of architectural drawing (from Albuquerque Area Indian Health ...
16 Photocopy of architectural drawing (from Albuquerque Area Indian Health Service, Division of Health Facilities, Albuquerque, New Mexico) Mayers Murray, and Phillip, Architects, New York, NY, 1934 first floor mechanical plan - heating - Taos Indian Health Center, 0.3 mile south-southwest of Pueblos Plaza, Taos Pueblo, Taos County, NM
10 CFR Appendix A to Part 440 - Standards for Weatherization Materials
Code of Federal Regulations, 2014 CFR
2014-01-01
...] Insulate tank and distribution piping (See insulation section of this appendix). Install heat traps on..., Ceilings, Attics, and Roofs Insulation—organic fiber—conformance to Interim Safety Standard in 16 CFR part 1209; Fire Safety Requirements for Thermal Insulating Materials According to Insulation Use—Attic Floor...
10 CFR Appendix A to Part 440 - Standards for Weatherization Materials
Code of Federal Regulations, 2011 CFR
2011-01-01
...] Insulate tank and distribution piping (See insulation section of this appendix). Install heat traps on..., Ceilings, Attics, and Roofs Insulation—organic fiber—conformance to Interim Safety Standard in 16 CFR part 1209; Fire Safety Requirements for Thermal Insulating Materials According to Insulation Use—Attic Floor...
10 CFR Appendix A to Part 440 - Standards for Weatherization Materials
Code of Federal Regulations, 2013 CFR
2013-01-01
...] Insulate tank and distribution piping (See insulation section of this appendix). Install heat traps on..., Ceilings, Attics, and Roofs Insulation—organic fiber—conformance to Interim Safety Standard in 16 CFR part 1209; Fire Safety Requirements for Thermal Insulating Materials According to Insulation Use—Attic Floor...
10 CFR Appendix A to Part 440 - Standards for Weatherization Materials
Code of Federal Regulations, 2012 CFR
2012-01-01
...] Insulate tank and distribution piping (See insulation section of this appendix). Install heat traps on..., Ceilings, Attics, and Roofs Insulation—organic fiber—conformance to Interim Safety Standard in 16 CFR part 1209; Fire Safety Requirements for Thermal Insulating Materials According to Insulation Use—Attic Floor...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Yixing; Hong, Tianzhen
We present that urban-scale building energy modeling (UBEM)—using building modeling to understand how a group of buildings will perform together—is attracting increasing attention in the energy modeling field. Unlike modeling a single building, which will use detailed information, UBEM generally uses existing building stock data consisting of high-level building information. This study evaluated the impacts of three zoning methods and the use of floor multipliers on the simulated energy use of 940 office and retail buildings in three climate zones using City Building Energy Saver. The first zoning method, OneZone, creates one thermal zone per floor using the target building'smore » footprint. The second zoning method, AutoZone, splits the building's footprint into perimeter and core zones. A novel, pixel-based automatic zoning algorithm is developed for the AutoZone method. The third zoning method, Prototype, uses the U.S. Department of Energy's reference building prototype shapes. Results show that simulated source energy use of buildings with the floor multiplier are marginally higher by up to 2.6% than those modeling each floor explicitly, which take two to three times longer to run. Compared with the AutoZone method, the OneZone method results in decreased thermal loads and less equipment capacities: 15.2% smaller fan capacity, 11.1% smaller cooling capacity, 11.0% smaller heating capacity, 16.9% less heating loads, and 7.5% less cooling loads. Source energy use differences range from -7.6% to 5.1%. When comparing the Prototype method with the AutoZone method, source energy use differences range from -12.1% to 19.0%, and larger ranges of differences are found for the thermal loads and equipment capacities. This study demonstrated that zoning methods have a significant impact on the simulated energy use of UBEM. Finally, one recommendation resulting from this study is to use the AutoZone method with floor multiplier to obtain accurate results while balancing the simulation run time for UBEM.« less
Chen, Yixing; Hong, Tianzhen
2018-02-20
We present that urban-scale building energy modeling (UBEM)—using building modeling to understand how a group of buildings will perform together—is attracting increasing attention in the energy modeling field. Unlike modeling a single building, which will use detailed information, UBEM generally uses existing building stock data consisting of high-level building information. This study evaluated the impacts of three zoning methods and the use of floor multipliers on the simulated energy use of 940 office and retail buildings in three climate zones using City Building Energy Saver. The first zoning method, OneZone, creates one thermal zone per floor using the target building'smore » footprint. The second zoning method, AutoZone, splits the building's footprint into perimeter and core zones. A novel, pixel-based automatic zoning algorithm is developed for the AutoZone method. The third zoning method, Prototype, uses the U.S. Department of Energy's reference building prototype shapes. Results show that simulated source energy use of buildings with the floor multiplier are marginally higher by up to 2.6% than those modeling each floor explicitly, which take two to three times longer to run. Compared with the AutoZone method, the OneZone method results in decreased thermal loads and less equipment capacities: 15.2% smaller fan capacity, 11.1% smaller cooling capacity, 11.0% smaller heating capacity, 16.9% less heating loads, and 7.5% less cooling loads. Source energy use differences range from -7.6% to 5.1%. When comparing the Prototype method with the AutoZone method, source energy use differences range from -12.1% to 19.0%, and larger ranges of differences are found for the thermal loads and equipment capacities. This study demonstrated that zoning methods have a significant impact on the simulated energy use of UBEM. Finally, one recommendation resulting from this study is to use the AutoZone method with floor multiplier to obtain accurate results while balancing the simulation run time for UBEM.« less
Operational Testing of Floor Cleaning Cloths for Household ...
Report The objective of this study was to evaluate the Swiffer® Sweeper® floor mop system (SSFMS) as a low-tech method to clean indoor residential floors contaminated with B. anthracis spores (the causative agent of anthrax).
Chikwanda, Allen Tapiwa; Muchenje, Voster
2017-01-01
Objective Purpose was to determine the effects of grazing system and floor type on concentrations of blood metabolites, activity of creatine kinase, body weight and carcass characteristics of castrated Nguni goats. Methods Forty eight, 7 month old goats were randomly allocated to herding and tethering treatments from 0800 to 1300 hours and accommodated on slatted and earth floors daily. Blood samples were collected by jugular venipuncture every fifteenth day for metabolite analysis. Slaughter was done at a commercial abattoir following 5 months of monitoring. Results Tethered goats had significantly higher concentrations of urea (5.19 mmol/L) (p< 0.001), creatinine (55.87 μmol/L) (p<0.05), total protein (64.60 g/L) (p<0.01), and globulin (49.79 g/L) (p<0.001), whereas herded goats had higher glucose (3.38 mmol/L) (p<0.001), albumin (15.33 g/L) (p<0.05), albumin/globulin ratio (0.34) (p<0.01), and body weight (24.87 kg) (p< 0.001). Slatted floors caused higher (p<0.01) albumin at 15.37 g/L. The interaction of grazing system and floor type affected creatinine, total protein, globulin at (p<0.01) and albumen/globulin ratio at (p<0.01). The least creatinine concentration and albumin/globulin ratio was in herded and tethered goats that were accommodated on earth floors, respectively. The highest total protein and globulin concentrations were in serum of tethered goats that were accommodated on earth floors. The highest (p<0.05) dressing percentage (45.26%) was in herded goats accommodated on slatted floors. Conclusion Herding of goats lowered globulin concentration, improved estimated feed intake, blood glucose and albumin concentrations, albumin globulin ratio, increased body weights and weight related carcass characteristics. Floor type had very little effects on metabolites where earth floors only reduced albumin concentration. Tethering and housing goats on earth floors resulted in double stress that increased chronic infections. PMID:28002930
Wright, Alexander D; Laing, Andrew C
2012-10-01
Novel compliant flooring systems are a promising approach for reducing fall-related injuries in seniors, as they may provide up to 50% attenuation in peak force during simulated hip impacts while eliciting only minimal influences on balance. This study aimed to determine the protective capacity of novel compliant floors during simulated 'high severity' head impacts compared to common flooring systems. A headform was impacted onto a common Commercial-Carpet at 1.5, 2.5, and 3.5 m/s in front, back, and side orientations using a mechanical drop tower. Peak impact force applied to the headform (F(max)), peak linear acceleration of the headform (g(max)) and Head Injury Criterion (HIC) were determined. For the 3.5 m/s trials, backwards-oriented impacts were associated with the highest F(max) and HIC values (p<0.001); accordingly, this head orientation was used to complete additional trials on three common floors (Resilient Rubber, Residential-Loop Carpet, Berber Carpet) and six novel compliant floors at each impact velocity. ANOVAs indicated that flooring type was associated with all parameters at each impact velocity (p<0.001). Compared to impacts on the Commercial Carpet, Dunnett's post hoc indicated all variables were smaller (25-80%) for the novel compliant floors (p<0.001), but larger for Resilient Rubber (31-159%, p<0.01). This study demonstrates that during 'high severity' simulated impacts, novel compliant floors can substantially reduce the forces and accelerations applied to a headform compared to common floors including carpet and resilient rubber. In combination with reports of minimal balance impairments, these findings support the promise of novel compliant floors as a biomechanically effective strategy for reducing fall-related injuries including traumatic brain injuries and skull fractures. Copyright © 2011 IPEM. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Apte, Michael G.; Apte, Joshua S.
2010-04-27
The Paharpur Business Centre and Software Technology Incubator Park (PBC) is a 7 story, 50,400 ft{sup 2} office building located near Nehru Place in New Delhi India. The occupancy of the building at full normal operations is about 500 people. The building management philosophy embodies innovation in energy efficiency while providing full service and a comfortable, safe, healthy environment to the occupants. Provision of excellent Indoor Air Quality (IAQ) is an expressed goal of the facility, and the management has gone to great lengths to achieve it. This is particularly challenging in New Delhi, where ambient urban pollution levels rankmore » among the worst on the planet. The approach to provide good IAQ in the building includes a range of technical elements: air washing and filtration of ventilation intake air from rooftop air handler, the use of an enclosed rooftop greenhouse with a high density of potted plants as a bio-filtration system, dedicated secondary HVAC/air handling units on each floor with re-circulating high efficiency filtration and UVC treatment of the heat exchanger coils, additional potted plants for bio-filtration on each floor, and a final exhaust via the restrooms located at each floor. The conditioned building exhaust air is passed through an energy recovery wheel and chemisorbent cartridge, transferring some heat to the incoming air to increase the HVAC energy efficiency. The management uses 'green' cleaning products exclusively in the building. Flooring is a combination of stone, tile and 'zero VOC' carpeting. Wood trim and finish appears to be primarily of solid sawn materials, with very little evidence of composite wood products. Furniture is likewise in large proportion constructed from solid wood materials. The overall impression is that of a very clean and well-kept facility. Surfaces are polished to a high sheen, probably with wax products. There was an odor of urinal cake in the restrooms. Smoking is not allowed in the building. The plants used in the rooftop greenhouse and on the floors were made up of a number of species selected for the following functions: daytime metabolic carbon dioxide (CO{sub 2}) absorption, nighttime metabolic CO{sub 2} absorption, and volatile organic compound (VOC) and inorganic gas absorption/removal for air cleaning. The building contains a reported 910 indoor plants. Daytime metabolic species reported by the PBC include Areca Palm, Oxycardium, Rubber Plant, and Ficus alii totaling 188 plants (21%). The single nighttime metabolic species is the Sansevieria with a total of 28 plants (3%). The 'air cleaning' plant species reported by the PBC include the Money Plant, Aglaonema, Dracaena Warneckii, Bamboo Palm, and Raphis Palm with a total of 694 plants (76%). The plants in the greenhouse (Areca Palm, Rubber Plant, Ficus alii, Bamboo Palm, and Raphis Palm) numbering 161 (18%) of those in the building are grown hydroponically, with the room air blown by fan across the plant root zones. The plants on the building floors are grown in pots and are located on floors 1-6. We conducted a one-day monitoring session in the PBC on January 1, 2010. The date of the study was based on availability of the measurement equipment that the researchers had shipped from Lawrence Berkeley National Lab in the U.S.A. The study date was not optimal because a large proportion of the regular building occupants were not present being New Year's Day. An estimated 40 people were present in the building all day during January 1. This being said, the building systems were in normal operations, including the air handlers and other HVAC components. The study was focused primarily on measurements in the Greenhouse and 3rd and 5th floor environments as well as rooftop outdoors. Measurements included a set of volatile organic compounds (VOCs) and aldehydes, with a more limited set of observations of indoor and outdoor particulate and carbon dioxide concentrations. Continuous measurements of Temperature (T) and relative humidity (RH) were made selected indoor and outdoor locations.« less
NASA Astrophysics Data System (ADS)
Schnepp, Elisabeth; Lanos, Philippe; Chauvin, Annick
2009-08-01
Geomagnetic paleointensities have been determined from a single archaeological site in Lübeck, Germany, where a sequence of 25 bread oven floors has been preserved in a bakery from medieval times until today. Age dating confines the time interval from about 1300 A.D. to about 1750 A.D. Paleomagnetic directions have been published from each oven floor and are updated here. The specimens have very stable directions and no or only weak secondary components. The oven floor material was characterized rock magnetically using Thellier viscosity indices, median destructive field values, Curie point determinations, and hysteresis measurements. Magnetic carriers are mixtures of SD, PSD, and minor MD magnetite and/or maghemite together with small amounts of hematite. Paleointensity was measured from selected specimens with the double-heating Thellier method including pTRM checks and determination of TRM anisotropy tensors. Corrections for anisotropy as well as for cooling rate turned out to be unnecessary. Ninety-two percent of the Thellier experiments passed the assigned acceptance criteria and provided four to six reliable paleointensity estimates per oven floor. Mean paleointensity values derived from 22 oven floors show maxima in the 15th and early 17th centuries A.D., followed by a decrease of paleointensity of about 20% until 1750 A.D. Together with the directions the record represents about 450 years of full vector secular variation. The results compare well with historical models of the Earth's magnetic field as well as with a selected high-quality paleointensity data set for western and central Europe.
Reducing Floor Impact Vibration and Sound Using a Momentum Exchange Impact Damper
NASA Astrophysics Data System (ADS)
Son, Lovely; Kawachi, Makoto; Matsuhisa, Hiroshi; Utsuno, Hideo
This paper deals with reducing floor impact vibration and sound by using a momentum exchange impact damper. The impact damper consists of a spring and a mass that is contact with the floor. When a falling object collides with the floor, the floor interacts with the damper mass, and the momentum of the falling object is transferred to the damper. In this works a computational model is formulated to simulate dynamic floor vibration induced by impact. The floor vibration is simulated for various sized damper masses. A proof-of-concept experimental apparatus was fabricated to represent a floor with an impact damper. This example system consists of an acrylic plate, a ball for falling object, and an impact damper. A comparison between simulated and experimental results were in good agreement in suggesting that the proposed impact damper is effective at reducing floor impact vibration and sound by 25% and 63%, respectively.
Samuel V. Glass; Charles G. Carll; Jay P. Curole; Matthew D. Voitier
2010-01-01
In flood-prone areas, elevating a buildingâs floor system above the anticipated flood level can significantly limit the extent of property damage associated with flooding. In hot and humid climates, such as the Gulf Coast region, raised floor systems may, however, be at risk for seasonal moisture accumulation, as the majority of residential buildings in such climates...
6. Main span (parker through truss, detail of floor system ...
6. Main span (parker through truss, detail of floor system and bottom lateral bracing; looking northwest. - Bridge 4666, Minnesota Trunk Highway 19 spanning Minnesota River, North Redwood, Redwood County, MN
Third floor, showing monorail system, scale (center left), alum dump ...
Third floor, showing monorail system, scale (center left), alum dump bucket, and dissolving tanks - Division Avenue Pumping Station & Filtration Plant, West 45th Street and Division Avenue, Cleveland, Cuyahoga County, OH
Floor Plans Rolling Platform, Tech Systems Platform, and Load ...
Floor Plans - Rolling Platform, Tech Systems Platform, and Load Platform Plans - Marshall Space Flight Center, F-1 Engine Static Test Stand, On Route 565 between Huntsville and Decatur, Huntsville, Madison County, AL
Falls from height during the floor slab formwork of buildings: current situation in Spain.
Adam, Jose M; Pallarés, Francisco J; Calderón, Pedro A
2009-01-01
One of the phases with the highest risk of falls from a height in the construction of a building is during the floor slab formwork stage. This paper analyzes this particular risk, as well as the most frequently used fall-protection systems. A survey was carried out to define the current situation in Spain with regard to falls from a height during floor slab formwork and the fall-protection systems used to prevent such a risk. The results of the survey clarified the current situation in Spain with regard to this risk, and made it clear that there is considerable risk of falling from a height during the floor slab formwork stage. All the safety systems analyzed presented a series of weak points that should be studied in detail before they can be used on building sites. The risk of falling associated with floor slab formwork and the most frequently used protection systems are analyzed. As no research had been carried out to date on this type of risk, we consider the research presented in this article to be a pioneer in the field.
Characterization of the protective capacity of flooring systems using force-deflection profiling.
Glinka, Michal N; Karakolis, Thomas; Callaghan, Jack P; Laing, Andrew C
2013-01-01
'Safety floors' aim to decrease the risk of fall-related injuries by absorbing impact energy during falls. Ironically, excessive floor deflection during walking or standing may increase fall risk. In this study we used a materials testing system to characterize the ability of a range of floors to absorb energy during simulated head and hip impacts while resisting deflection during simulated single-leg stance. We found that energy absorption for all safety floors (mean (SD)=14.8 (4.9)J) and bedside mats (25.1 (9.3)J) was 3.2- to 5.4-fold greater than the control condition (commercial carpet). While footfall deflections were not significantly different between safety floors (1.8 (0.7)mm) and the control carpet (3.7 (0.6)mm), they were significantly higher for two bedside mats. Finally, all of the safety floors, and two bedside mats, displayed 3-10 times the energy-absorption-to-deflection ratios observed for the baseline carpet. Overall, these results suggest that the safety floors we tested effectively addressed two competing demands required to reduce fall-related injury risk; namely the ability to absorb substantial impact energy without increasing footfall deflections. This study contributes to the literature suggesting that safety floors are a promising intervention for reducing fall-related injury risk in older adults. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.
The effect of non-gravitational gas heating in groups and clusters of galaxies
NASA Astrophysics Data System (ADS)
Borgani, S.; Governato, F.; Wadsley, J.; Menci, N.; Tozzi, P.; Quinn, T.; Stadel, J.; Lake, G.
2002-10-01
We present a detailed study of a set of gas-dynamical simulations of galaxy groups and clusters in a flat, Λ-cold dark matter (ΛCDM) model with Ωm= 0.3, aimed at exploring the effect of non-gravitational heating on the observable properties of the intracluster medium (ICM). We use GASOLINE, a version of the code PKDGRAV that includes a smoothed particle hydrodynamics description of hydrodynamics to simulate the formation of four haloes with virial temperatures in the range 0.5 <~T<~ 8 keV. These simulations resolve the structure and properties of the ICM down to a small fraction of the virial radius, Rvir. At our resolution X-ray luminosities, LX, of runs with gravitational heating only are in good agreement with analytical predictions, which assume a universal profile for CDM haloes, over almost two orders of magnitude in mass. For each simulated structure, non-gravitational heating of the ICM is implemented in two different ways: (i) by imposing a minimum-entropy floor, Sfl, at a given redshift, which we take in the range 1<=z<= 5; (ii) by gradually heating gas within collapsed regions, proportionally to the supernova rate expected from semi-analytical modelling of galaxy formation in haloes having mass equal to that of the simulated systems. Our main results are the following. (i) An extra heating energy Eh>~ 1 keV per gas particle within Rvir at z= 0 is required to reproduce the observed LX-T relation, independent of whether it is provided in an impulsive way to create an entropy floor Sfl= 50-100 keV cm2, or is modulated in redshift according to the star formation rate; our supernova (SN) feedback recipe provides at most Eh~= 1/3 keV particle-1 and, therefore, its effect on the LX-T relation is too small to account for the observed LX-T relation. (ii) The required heating implies, in small groups with T~ 0.5 keV, a baryon fraction as low as <~40 per cent of the cosmic value at Rvir/2 this fraction increases to about 80 per cent for a T~= 3 keV cluster. (iii) Temperature profiles are almost scale-free across the whole explored mass range, with T decreasing by a factor of 3 at the virial radius. (iv) The mass-temperature relation is almost unaffected by non-gravitational heating and follows quite closely the M~T3/2 scaling; however, when compared with data on the M500-Tew relation, it has a ~40 per cent higher normalization. This discrepancy is independent of the heating scheme adopted. The inclusion of cooling in a run of a small group steepens the central profile of the potential well while removing gas from the diffuse phase. This has the effects of increasing Tew by ~30 per cent, possibly reconciling the simulated and the observed M500-Tew relations, and of decreasing LX by ~40 per cent. However, in spite of the inclusion of SN feedback energy, almost 40 per cent of the gas drops out from the hot diffuse phase, in excess of current observational estimates of the number of cold baryons in galaxy systems. It is likely that only a combination of different heating sources (SNe and active galactic nuclei) and cooling will be able to reproduce both the LX-Tew and M500-Tew relations, as observed in groups and clusters, while balancing the cooling runaway.
Seasonal performance for Heat pump with vertical ground heat exchanger in Riga
NASA Astrophysics Data System (ADS)
Jaundālders, S.; Stanka, P.; Rusovs, D.
2017-10-01
Experimental measurements of Seasonal Coefficient of Performance (SCOP) for heating of 160 m2 household in Riga were conducted for operation of brine-water heat pump with vertical ground heat exchangers (GHE). Data regarding heat and electrical power consumption were recorded during three-year period from 2013 to 2016. Vapor compression heat pump has heat energy output of 8 kW. GHE consists of three boreholes. Each borehole is 60 m deep. Data regarding brine temperature for borehole input and output were presented and discussed. As far as house had floor heating, there were presented data about COP for B0/W35 and its dependence from room and outdoor temperature during heating season. Empirical equation was created. Average heat energy consumption during one year for heating was 72 kWh/m2 measured by heat meter. Detected primary energy consumption (electrical energy from grid) was 21 kWh/m2 which resulted in SCOP=3.8. These data were compared with SCOP for air-to-water heat pump in Latvia and available configuration software for heat pumps operation. Good agreement between calculated performance and reported experimental data were founded.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
Designing a superinsulated home has many benefits including improved comfort, reduced exterior noise penetration, lower energy bills, and the ability to withstand power and fuel outages under much more comfortable conditions than a typical home. Extremely low heating and cooling loads equate to much smaller HVAC equipment than conventionally required. Sizing the mechanical system to these much lower loads reduces first costs and the size of the distribution system needed. While these homes aren't necessarily constructed with excessive mass in the form of concrete floors and walls, the amount of insulation and the increase in the thickness of the buildingmore » envelope can lead to a mass effect, resulting in the structures ability to store much more heat than a code built home. This results in a very low thermal inertia making the building much less sensitive to drastic temperature swings thereby decreasing the peak heating load demand. Alternative methods that take this inertia into account along with solar and internal gains result in smaller more appropriate design loads than those calculated using Manual J version 8. During the winter of 2013/2014, the Consortium for Advanced Residential Buildings team monitored the energy use of three homes in climate zone 6 in an attempt to evaluate the accuracy of two different mechanical system sizing methods for low load homes. Based on the results, it is recommended that internal and solar gains be included and some credit for thermal inertia be used in sizing calculations for superinsulated homes.« less
Heat flow anomalies and their interpretation
NASA Astrophysics Data System (ADS)
Chapman, David S.; Rybach, Ladislaus
1985-12-01
More than 10,000 heat flow determinations exist for the earth and the data set is growing steadily at about 450 observations per year. If heat flow is considered as a surface expression of geothermal processes at depth, the analysis of the data set should reveal properties of those thermal processes. They do, but on a variety of scales. For this review heat flow maps are classified by 4 different horizontal scales of 10 n km (n = 1, 2, 3 and 4) and attention is focussed on the interpretation of anomalies which appear with characteristic dimensions of 10 (n - 1) km in the respective representations. The largest scale of 10 4 km encompasses heat flow on a global scale. Global heat loss is 4 × 10 13 W and the process of sea floor spreading is the principal agent in delivering much of this heat to the surface. Correspondingly, active ocean ridge systems produce the most prominent heat flow anomalies at this scale with characteristic widths of 10 3 km. Shields, with similar dimensions, exhibit negative anomalies. The scale of 10 3 km includes continent wide displays. Heat flow patterns at this scale mimic tectonic units which have dimensions of a few times 10 2 km, although the thermal boundaries between these units are sometimes sharp. Heat flow anomalies at this scale also result from plate tectonic processes, and are associated with arc volcanism, back arc basins, hot spot traces, and continental rifting. There are major controversies about the extent to which these surface thermal provinces reflect upper mantle thermal conditions, and also about the origin and evolution of the thermal state of continental lithosphere. Beginning with map dimensions of 10 2 km thermal anomalies of scale 10 1 km, which have a definite crustal origin, become apparent. The origin may be tectonic, geologic, or hydrologic. Ten kilometers is a common wavelength of topographic relief which drives many groundwater flow systems producing thermal anomalies. The largest recognized continental geothermal systems have thermal anomalies 10 1 km wide and are capable of producing hundreds of megawatts of thermal energy. The smallest scale addressed in this paper is 10 1 km. Worldwide interest in exploiting geothermal systems has been responsible for a recent accumulation of heat flow data on the smallest of scales considered here. The exploration nature of the surveys involve 10's of drillholes and reveal thermal anomalies having widths of 10 0 km. These are almost certainly connected to surface and subsurface fluid discharge systems which, in spite of their restricted size, are typically delivering 10 MW of heat to the near surface environment.
Monitoring a supervolcano in repose: Heat and volatile flux at the yellostone caldera
Lowenstern, J. B.; Hurwitz, S.
2008-01-01
Although giant calderas ("supervolcanoes") may slumber for tens of thousands of years between eruptions, their abundant earthquakes and crustal deformation reveal the potential for future upheaval. Any eventual supereruption could devastate global human populations, so these systems must be carefully scrutinized. Insight into dormant but restless calderas can be gained by monitoring their output of heat and gas. At Yellowstone, the large thermal and CO2 fluxes require massive input of basaltic magma, which continues to invade the lower to mid-crust, sustains the overlying high-silica magma reservoir, and may result in volcanic hazard for millennia to come. The high flux of CO2 may contribute to the measured deformation of the caldera floor and can also modify the pressure, thermal, and chemical signals emitted from the magma. In order to recognize precursors to eruption, we must scrutinize the varied signals emerging from restless calderas with the goal of discriminating magmatic, hydrothermal, and hybrid phenomena.
Small scale power generation from biomass-technical potential
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lepori, W.A.; Cardenas, M.M.; Carney, O.B.
1983-12-01
System and nursery pig performance data for the Winter of 1983 were collected for a 96-pig capacity modified-open-front (MOF) naturally ventilated and a 96-pig capacity mechanically ventilated swine nurseries. Both nurseries utilized active solar collectors to provide in-floor heating at the rear of each pen along with hovers. The mechanically ventilated nursery utilized solar preheated ventilation air. The naturally ventilated nursery had double glazed solar windows to passively heat the interior space. The relative humidity in the naturally ventilated (NV) nursery averaged 20 percentage points higher than the mechanically ventilated (MV) nursery with no significant differences in air temperature. Themore » MV nursery used 50% more energy than the NV nursery and the NV nursery required 1.9 kWh/pig marketed less than that needed for the MV nursery. Pig performance figure were not significantly different between the two buildings. The feed to gain ration were 2.0 + or - 0.35 and 1.96 + or 0.38 for the MV and NV nurseries respectively.« less
Air temperature gradient in large industrial hall
NASA Astrophysics Data System (ADS)
Karpuk, Michał; Pełech, Aleksander; Przydróżny, Edward; Walaszczyk, Juliusz; Szczęśniak, Sylwia
2017-11-01
In the rooms with dominant sensible heat load, volume airflow depends on many factors incl. pre-established temperature difference between exhaust and supply airflow. As the temperature difference is getting higher, airflow volume drops down, consequently, the cost of AHU is reduced. In high industrial halls with air exhaust grids located under the ceiling additional temperature gradient above working zone should be taken into consideration. In this regard, experimental research of the vertical air temperature gradient in high industrial halls were carried out for the case of mixing ventilation system The paper presents the results of air temperature distribution measurements in high technological hall (mechanically ventilated) under significant sensible heat load conditions. The supply airflow was delivered to the hall with the help of the swirl diffusers while exhaust grids were located under the hall ceiling. Basing on the air temperature distribution measurements performed on the seven pre-established levels, air temperature gradient in the area between 2.0 and 7.0 m above the floor was calculated and analysed.
23. VIEW OF THE FIRST FLOOR PLAN. THE FIRST FLOOR ...
23. VIEW OF THE FIRST FLOOR PLAN. THE FIRST FLOOR HOUSED ADMINISTRATIVE OFFICES, THE CENTRAL COMPUTING, UTILITY SYSTEMS, ANALYTICAL LABORATORIES, AND MAINTENANCE SHOPS. THE ORIGINAL DRAWING HAS BEEN ARCHIVED ON MICROFILM. THE DRAWING WAS REPRODUCED AT THE BEST QUALITY POSSIBLE. LETTERS AND NUMBERS IN THE CIRCLES INDICATE FOOTER AND/OR COLUMN LOCATIONS. - Rocky Flats Plant, General Manufacturing, Support, Records-Central Computing, Southern portion of Plant, Golden, Jefferson County, CO
20. Photocopy of architectural drawing, September 1942 (original on file ...
20. Photocopy of architectural drawing, September 1942 (original on file at U.S. Army Intelligence Security Command, Fort Belvoir, Virginia). OPERATIONS BUILDING 'A', ARLINGTON HALL STATION. OFFICE BUILDING -- SECOND FLOOR PLAN -- HEATING. DRAWING M-24-161-26. - Arlington Hall Station, Building No. 401, 4000 Arlington Boulevard, Arlington, Arlington County, VA
19. Photocopy of architectural drawing, September 1942 (original on file ...
19. Photocopy of architectural drawing, September 1942 (original on file at U.S. Army Intelligence Security Command, Fort Belvoir, Virginia). OPERATIONS BUILDING 'A', ARLINGTON HALL STATION. OFFICE BUILDING -- FIRST FLOOR PLAN -- HEATING. DRAWING M-24-161-25. - Arlington Hall Station, Building No. 401, 4000 Arlington Boulevard, Arlington, Arlington County, VA
Wolfhounds and Polar Bears in Siberia: America’s Military Intervention, 1918-1920
1986-01-01
including sable, sea otter, otter, beaver, mink, muskrat, squirrel, fox, skunk, woodchuck, marmot , badger, glutton, and rabbit. Vast forests provided wood for...venti- lated, heated, and lighted. A kitchen was found on the end of each floor in the barracks. Latrines drained into open cesspools. Wood burning
NASA Astrophysics Data System (ADS)
Cardinale, Tiziana; Rospi, Gianluca; Cardinale, Nicola; Paterino, Lucia; Persia, Ivan
2014-05-01
The Matera Cathedral was built in Apulian-Romanesque style in the thirteenth century on the highest spur of the "Civita" that divides "Sassi" district in two parts. The constructive material is the calcareous stone of the Vaglia, extracted from quarries in the area of Matera. The interior is Baroque and presents several artworks, including: mortars covered with a golden patina, a wooden ceiling, painted canvas and painting frescoes, three minor altars and a major altar of precious white marble, a nativity scene made of local painted limestone. The research had to evaluate the indoor microclimate during and after the restoration works, that also concern the installation of floor heating system to heat the indoor environments. Specifically, we have analyzed the thermal comfort and the effect that the artwork and construction materials inside the Cathedral of Matera have undergone. This evaluation was carried out in two different phases: in the first one we have investigated the state of the art (history of the site, constructive typology and artworks); in the second one we have done a systematic diagnosis and an instrumental one. The analysis were carried out in a qualitative and quantitative way and have allowed us to test indoor microclimatic parameters (air temperature, relative humidity and indoor air velocity), surface temperatures of the envelope and also Fanger's comfort indices (PMV and PPD) according to the UNI EN ISO 7730. The thermal mapping of the wall surface and of the artworks, carried out through thermal imaging camera, and the instrumental measurement campaigns were made both before restoration and after installation of the heating system; in addition measurements were taken with system on and off. The analysis thus made possible to verify that the thermo-hygrometric parameters found, as a result of the recovery operations, meet the limits indicated by the regulations and international studies. In this way, we can affirm that the indoor environment of the Cathedral of Matera is suitable both from the point of view of indoor comfort (both during the summer and the winter season) and of microclimatic parameters that are in the intervals prescribed by the regulations on the conservation of artworks of art (Ministerial Decree of 10/05/2001 dictated by the Ministry for heritage and cultural activities). Moreover the energy performance of the building-plant system was evaluated according to the Italian Norm UNI TS 11300. In particular the summer comfort is guaranteed by the huge thermal inertia of the structure that reduces the internal temperature fluctuation. Instead, the winter comfort is guaranteed by the floor heating system, which through the use of evolving fluid at low temperatures, also ensures higher efficiency and significant energy savings, as well as the protection and conservation of the artistic heritage present in the Cathedral.
NASA Astrophysics Data System (ADS)
Aghababaei, Sajjad; Saeedi, Gholamreza; Jalalifar, Hossein
2016-05-01
The floor failure at longwall face decreases productivity and safety, increases operation costs, and causes other serious problems. In Parvadeh-I coal mine, the timber is used to prevent the puncture of powered support base into the floor. In this paper, a rock engineering system (RES)-based model is presented to evaluate the risk of floor failure mechanisms at the longwall face of E 2 and W 1 panels. The presented model is used to determine the most probable floor failure mechanism, effective factors, damaged regions and remedial actions. From the analyzed results, it is found that soft floor failure is dominant in the floor failure mechanism at Parvadeh-I coal mine. The average of vulnerability index (VI) for soft, buckling and compressive floor failure mechanisms was estimated equal to 52, 43 and 30 for both panels, respectively. By determining the critical VI for soft floor failure mechanism equal to 54, the percentage of regions with VIs beyond the critical VI in E 2 and W 1 panels is equal to 65.5 and 30, respectively. The percentage of damaged regions showed that the excess amount of used timber to prevent the puncture of weak floor below the powered support base is equal to 4,180,739 kg. RES outputs and analyzed results showed that setting and yielding load of powered supports, length of face, existent water at face, geometry of powered supports, changing the cutting pattern at longwall face and limiting the panels to damaged regions with supercritical VIs could be considered to control the soft floor failure in this mine. The results of this research could be used as a useful tool to identify the damaged regions prior to mining operation at longwall panel for the same conditions.
Floor Proximity Emergency Escape Path Marking Systems Incorporating Photoluminescent Elements
DOT National Transportation Integrated Search
1997-07-24
This advisory circular (AC) provides guidance material for use in demonstrating : compliance with the provisions of part 25 of the Federal Aviation Regulations : (FAR) regarding floor proximity emergency escape path marking systems (FPEEPMS) : which ...
VIEW OF NORTH SAN GABRIEL RIVER BRIDGE, FLOOR SYSTEM AND ...
VIEW OF NORTH SAN GABRIEL RIVER BRIDGE, FLOOR SYSTEM AND LATERAL BRACING, LOOKING SOUTH. - North San Gabriel River Bridge, Spanning North Fork of San Gabriel River at Business Route 35, Georgetown, Williamson County, TX
Floor Identification with Commercial Smartphones in Wifi-Based Indoor Localization System
NASA Astrophysics Data System (ADS)
Ai, H. J.; Liu, M. Y.; Shi, Y. M.; Zhao, J. Q.
2016-06-01
In this paper, we utilize novel sensors built-in commercial smart devices to propose a schema which can identify floors with high accuracy and efficiency. This schema can be divided into two modules: floor identifying and floor change detection. Floor identifying module starts at initial phase of positioning, and responsible for determining which floor the positioning start. We have estimated two methods to identify initial floor based on K-Nearest Neighbors (KNN) and BP Neural Network, respectively. In order to improve performance of KNN algorithm, we proposed a novel method based on weighting signal strength, which can identify floors robust and quickly. Floor change detection module turns on after entering into continues positioning procedure. In this module, sensors (such as accelerometer and barometer) of smart devices are used to determine whether the user is going up and down stairs or taking an elevator. This method has fused different kinds of sensor data and can adapt various motion pattern of users. We conduct our experiment with mobile client on Android Phone (Nexus 5) at a four-floors building with an open area between the second and third floor. The results demonstrate that our scheme can achieve an accuracy of 99% to identify floor and 97% to detecting floor changes as a whole.
ERIC Educational Resources Information Center
Cohen, Andrew
1998-01-01
Discusses wood-flooring components for athletic facilities, what materials make up these floors, and how they affect a floor's performance once installed. The pros and cons of anchored versus floating systems are examined, including the issue of moisture resistance. Also discussed is the influence of Deutsches Institut fur Normans (DIN) standards…
Maximizing Hard Floor Maintenance.
ERIC Educational Resources Information Center
Steger, Michael
2000-01-01
Explains the maintenance options available for hardwood flooring that can help ensure long life cycles and provide inviting spaces. Developing a maintenance system, knowing the type of traffic that the floor must endure, using entrance matting, and adhering to manufacturers guidelines are discussed. Daily, monthly or quarterly, and long-term…
Using artificial neural networks to model aluminium based sheet forming processes and tools details
NASA Astrophysics Data System (ADS)
Mekras, N.
2017-09-01
In this paper, a methodology and a software system will be presented concerning the use of Artificial Neural Networks (ANNs) for modeling aluminium based sheet forming processes. ANNs models’ creation is based on the training of the ANNs using experimental, trial and historical data records of processes’ inputs and outputs. ANNs models are useful in cases that processes’ mathematical models are not accurate enough, are not well defined or are missing e.g. in cases of complex product shapes, new material alloys, new process requirements, micro-scale products, etc. Usually, after the design and modeling of the forming tools (die, punch, etc.) and before mass production, a set of trials takes place at the shop floor for finalizing processes and tools details concerning e.g. tools’ minimum radii, die/punch clearance, press speed, process temperature, etc. and in relation with the material type, the sheet thickness and the quality achieved from the trials. Using data from the shop floor trials and forming theory data, ANNs models can be trained and created, and can be used to estimate processes and tools final details, hence supporting efficient set-up of processes and tools before mass production starts. The proposed ANNs methodology and the respective software system are implemented within the EU H2020 project LoCoMaTech for the aluminium-based sheet forming process HFQ (solution Heat treatment, cold die Forming and Quenching).
Feasibility Evaluation of an On-site Generator Network by the Cooperative Game Theory
NASA Astrophysics Data System (ADS)
Komiyama, Ryoichi; Hayashi, Taketo; Fujii, Yasumasa; Yamaji, Kenji
On-site generator, such as CGS (cogeneration system), is allegedly considered to be an effective end-use energy system in order to accomplish primary energy conservation, CO2 emission mitigation and system cost reduction, which characteristics eventually improve the whole performance of an existing energy system for the future. Considering the drawback of installing an end-use CGS into the customer with small or middle scale floor space, however, it is difficult to achieve those distinctive features because the thermal-electricity ratio of CGS does not always be in agreement with that of customer energy demand. In order to overcome that matching deficiency, it is hence better to organize an on-site generator network based on mutual electricity and heating transmission. But focusing on some cogenerators underlying their behaviors on maximizing their own profits, this on-site network, which situation corresponds to a grand coalition, is not necessarily established because of each cogenerator’s motivation to form a partial coalition and acquire its own profit as much as possible. In this paper, we attempt to analyze the optimal operation of an on-site generator network and identify by applying the nucleolus of the cooperative game theory the optimal benefit allocation strategy in order for the cogenerators to construct the network. Regarding the installation site of this network, the center of Tokyo area is assumed, which locational information includes floor space and so forth through a GIS (geographic information system) database. The results from the nucleolus suggest that all districts should impartially obtain the benefit from organizing network for the purpose of jointly attaining the system total cost reduction.
2011-07-12
CAPE CANAVERAL, Fla. -- At NASA's Kennedy Space Center in Florida, a forklift positions the protective mesh container enclosing the multi-mission radioisotope thermoelectric generator (MMRTG) for NASA's Mars Science Laboratory (MSL) mission onto the floor of the airlock of the Payload Hazardous Servicing Facility (PHSF). The container, known as the "gorilla cage," protects the MMRTG and allows any excess heat generated to dissipate into the air. In the PHSF, the MMRTG temporarily will be installed on the MSL rover, Curiosity, for a fit check but will be installed on the rover for launch at the pad. The MMRTG will generate the power needed for the mission from the natural decay of plutonium-238, a non-weapons-grade form of the radioisotope. Heat given off by this natural decay will provide constant power through the day and night during all seasons. Curiosity, MSL's car-sized rover, has 10 science instruments designed to search for signs of life, including methane, and help determine if the gas is from a biological or geological source. Waste heat from the MMRTG will be circulated throughout the rover system to keep instruments, computers, mechanical devices and communications systems within their operating temperature ranges. Launch of MSL aboard a United Launch Alliance Atlas V rocket is planned for Nov. 25 from Space Launch Complex 41 on Cape Canaveral Air Force Station. For more information, visit http://www.nasa.gov/msl. Photo credit: NASA/Cory Huston
2011-06-30
CAPE CANAVERAL, Fla. -- In the RTG storage facility at NASA's Kennedy Space Center in Florida, the multi-mission radioisotope thermoelectric generator (MMRTG) for NASA's Mars Science Laboratory mission, with guide rods still installed on its support base, has been uncovered on the high bay floor. The MMRTG no longer needs supplemental cooling since any excess heat generated can dissipate into the air in the high bay. The MMRTG will generate the power needed for the mission from the natural decay of plutonium-238, a non-weapons-grade form of the radioisotope. Heat given off by this natural decay will provide constant power through the day and night during all seasons. Waste heat from the MMRTG will be circulated throughout the rover system to keep instruments, computers, mechanical devices and communications systems within their operating temperature ranges. MSL's components include a compact car-sized rover, Curiosity, which has 10 science instruments designed to search for evidence on whether Mars has had environments favorable to microbial life, including chemical ingredients for life. The unique rover will use a laser to look inside rocks and release its gasses so that the rover’s spectrometer can analyze and send the data back to Earth. Launch of MSL aboard a United Launch Alliance Atlas V rocket is scheduled for Nov. 25 from Space Launch Complex 41 on Cape Canaveral Air Force Station in Florida. For more information, visit http://www.nasa.gov/msl. Photo credit: NASA/Frankie Martin
2011-07-14
CAPE CANAVERAL, Fla. -- A forklift moves into position to lift the multi-mission radioisotope thermoelectric generator (MMRTG) for NASA's Mars Science Laboratory (MSL) mission from the floor of the Payload Hazardous Servicing Facility (PHSF) airlock at NASA's Kennedy Space Center in Florida. The MMRTG is enclosed in a mesh container, known as the "gorilla cage," which protects it during transport and allows any excess heat generated to dissipate into the air. The MMRTG is being transported to the RTG storage facility following a fit check on MSL's Curiosity rover in the PHSF. The MMRTG will generate the power needed for the mission from the natural decay of plutonium-238, a non-weapons-grade form of the radioisotope. Heat given off by this natural decay will provide constant power through the day and night during all seasons. MSL's components include a compact car-sized rover, Curiosity, which has 10 science instruments designed to search for signs of life, including methane, and help determine if the gas is from a biological or geological source. Waste heat from the MMRTG will be circulated throughout the rover system to keep instruments, computers, mechanical devices and communications systems within their operating temperature ranges. Launch of MSL aboard a United Launch Alliance Atlas V rocket is targeted for Nov. 25 from Space Launch Complex 41 on Cape Canaveral Air Force Station. For more information, visit http://www.nasa.gov/msl. Photo credit: NASA/Troy Cryder
2011-07-14
CAPE CANAVERAL, Fla. -- A forklift moves into position to lift the multi-mission radioisotope thermoelectric generator (MMRTG) for NASA's Mars Science Laboratory (MSL) mission from the floor of the Payload Hazardous Servicing Facility (PHSF) airlock at NASA's Kennedy Space Center in Florida. The MMRTG is enclosed in a mesh container, known as the "gorilla cage," which protects it during transport and allows any excess heat generated to dissipate into the air. The MMRTG is being moved to the RTG storage facility following a fit check on MSL's Curiosity rover in the PHSF. The MMRTG will generate the power needed for the mission from the natural decay of plutonium-238, a non-weapons-grade form of the radioisotope. Heat given off by this natural decay will provide constant power through the day and night during all seasons. MSL's components include a compact car-sized rover, Curiosity, which has 10 science instruments designed to search for signs of life, including methane, and help determine if the gas is from a biological or geological source. Waste heat from the MMRTG will be circulated throughout the rover system to keep instruments, computers, mechanical devices and communications systems within their operating temperature ranges. Launch of MSL aboard a United Launch Alliance Atlas V rocket is targeted for Nov. 25 from Space Launch Complex 41 on Cape Canaveral Air Force Station. For more information, visit http://www.nasa.gov/msl. Photo credit: NASA/Troy Cryder
Brodersen, Søsser; Lindegaard, Hanne
2015-01-01
Currently, a wide variety of healthcare technologies are being implemented in private homes, hospitals, nursing homes, etc. with the triple aim of improving people's health, improving the quality of care, and reducing costs related to healthcare services. In this chapter, we discuss how different actors in a public-private partnership co-developed a heterogeneous system around the Smart Floor to ensure that both new healthcare practices and residents' routines were inscribed into the new healthcare technology. We argue that implementing the Smart Floor was not just a question of buying a technology and integrating it during construction-it required co-development with the healthcare staff. The floor is more than a technology placed under the floor surface in a resident's apartment; rather, it is a heterogeneous network of human and non-human actors communicating with each other. In this chapter, we illustrate how the heterogeneous technological system was co-developed and redesigned during knowledge sharing processes with companies, lead-users, and healthcare staff. We also discuss how care practices have changed as a result of the Smart Floor system. In particular, healthcare staff members no longer feel a need to disturb elderly residents with routine in-person checks. Domesticating the technologies for different groups of actors required not only coordinating communication among sensors, the interface, the portable nurse call (smartphones), and alarms, but also accepting the use of surveillance technology.
Effect of different flooring systems on weight and pressure distribution on claws of dairy cows.
Telezhenko, E; Bergsten, C; Magnusson, M; Ventorp, M; Nilsson, C
2008-05-01
Weight and pressure distribution on the claw were studied in Swedish Holsteins housed in different flooring systems. A total of 127 cows housed in different sections of the experimental barn were used. Each section had different flooring in the walking and standing areas. There were rubber mats or abrasive mastic asphalt flooring on the alleys or a low-abrasive slatted concrete floor. Some sections had feed-stalls equipped with rubber mats; other sections did not. The vertical ground reaction force, contact area, and average contact pressure were determined on the left hind foot using the I-Scan system and analyzed with the F-scan system. These determinations were made in each of the following 3 zones of the claw: bulb, wall, and sole. Most of the weight on claws exposed to concrete floors was carried by the bulb (37.4 +/- 3.5 and 18.3 +/- 2.9% of weight exerted on the foot in the lateral and medial claw, respectively) and the wall zone (20.0 +/- 2.6 and 13.4 +/- 2.4% on lateral and medial claw, respectively). The weight and pressure distribution in cows kept on sections with rubber covered alleys but passing daily over the asphalt floor on their way to the milking parlor did not differ in any zones, except for lateral bulbs, compared with those exposed to slatted concrete alone. Still, the weight bearing of the sole zone in cows kept on rubber mats without access to asphalt was less than that of cows kept on concrete slatted floors (5.1 +/- 0.7 vs. 12.7 +/- 1.1% and 1.1 +/- 0.5 vs. 8.7 +/- 0.7% in lateral and medial claws, respectively). In cows kept on asphalt flooring without feed-stalls, most weight was exerted to the sole zone (36.2 +/- 2.9 and 22.2 +/- 1.8% in lateral and medial claws, respectively). Feed-stalls in combination with asphalt flooring yielded a decreased total contact area (30.1 +/- 1.2 cm(2)) compared with asphalt floors without feed-stalls (35.7 +/- 1.2 cm(2)). The largest total contact area was obtained on the asphalt floor without feed-stalls, resulting in a lower contact pressure (39.8 +/- 2.3 N/cm(2)) than in claws exposed to concrete (66.0 +/- 2.7 N/ cm(2)) or rubber mats (56.7 +/- 1.7 N/cm(2)). In conclusion, housing with abrasive floors resulted in claws with increased contact area at the sole surface and therefore, decreased contact pressure, but reduced the weight-bearing role of the strongest part of the claw capsule, the claw wall.
12. INTERIOR OF COVERED WALKWAY BEHIND SECOND FLOOR APARTMENTS FROM ...
12. INTERIOR OF COVERED WALKWAY BEHIND SECOND FLOOR APARTMENTS FROM OPPOSITE VIEW OF CA-XXX-11. DOOR AT PHOTO LEFT OPENS INTO THE KITCHEN OF THE WEST SIDE SECOND FLOOR APARTMENT. VIEW TO EAST. - Lee Vining Creek Hydroelectric System, Triplex Cottage, Lee Vining Creek, Lee Vining, Mono County, CA
49 CFR 38.79 - Floors, steps and thresholds.
Code of Federal Regulations, 2014 CFR
2014-10-01
... SPECIFICATIONS FOR TRANSPORTATION VEHICLES Light Rail Vehicles and Systems § 38.79 Floors, steps and thresholds... have a band of color(s) running the full width of the step or threshold which contrasts from the step tread and riser or adjacent floor, either light-on-dark or dark-on-light. ...
49 CFR 38.79 - Floors, steps and thresholds.
Code of Federal Regulations, 2011 CFR
2011-10-01
... SPECIFICATIONS FOR TRANSPORTATION VEHICLES Light Rail Vehicles and Systems § 38.79 Floors, steps and thresholds... have a band of color(s) running the full width of the step or threshold which contrasts from the step tread and riser or adjacent floor, either light-on-dark or dark-on-light. ...
49 CFR 38.79 - Floors, steps and thresholds.
Code of Federal Regulations, 2012 CFR
2012-10-01
... SPECIFICATIONS FOR TRANSPORTATION VEHICLES Light Rail Vehicles and Systems § 38.79 Floors, steps and thresholds... have a band of color(s) running the full width of the step or threshold which contrasts from the step tread and riser or adjacent floor, either light-on-dark or dark-on-light. ...
49 CFR 38.79 - Floors, steps and thresholds.
Code of Federal Regulations, 2013 CFR
2013-10-01
... SPECIFICATIONS FOR TRANSPORTATION VEHICLES Light Rail Vehicles and Systems § 38.79 Floors, steps and thresholds... have a band of color(s) running the full width of the step or threshold which contrasts from the step tread and riser or adjacent floor, either light-on-dark or dark-on-light. ...
VIEW OF SOUTH SAN GABRIEL RIVER BRIDGE, FLOOR SYSTEM AND ...
VIEW OF SOUTH SAN GABRIEL RIVER BRIDGE, FLOOR SYSTEM AND LATERAL BRACING, LOOKING NORTH. - South San Gabriel River Bridge, Spanning South Fork of San Gabriel River at Georgetown at Business Route 35, Georgetown, Williamson County, TX
Low-cost three-dimensional gait analysis system for mice with an infrared depth sensor.
Nakamura, Akihiro; Funaya, Hiroyuki; Uezono, Naohiro; Nakashima, Kinichi; Ishida, Yasumasa; Suzuki, Tomohiro; Wakana, Shigeharu; Shibata, Tomohiro
2015-11-01
Three-dimensional (3D) open-field gait analysis of mice is an essential procedure in genetic and nerve regeneration research. Existing gait analysis systems are generally expensive and may interfere with the natural behaviors of mice because of optical markers and transparent floors. In contrast, the proposed system captures the subjects shape from beneath using a low-cost infrared depth sensor (Microsoft Kinect) and an opaque infrared pass filter. This means that we can track footprints and 3D paw-tip positions without optical markers or a transparent floor, thereby preventing any behavioral changes. Our experimental results suggest with healthy mice that they are more active on opaque floors and spend more time in the center of the open-field, when compared with transparent floors. The proposed system detected footprints with a comparable performance to existing systems, and precisely tracked the 3D paw-tip positions in the depth image coordinates. Copyright © 2015 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.
Bhan, Shivam; Levine, Iris; Laing, Andrew C
2013-12-01
The biomechanical effectiveness of safety floors has never been assessed during sideways falls with human volunteers. Furthermore, the influence of body mass index (BMI) and gender on the protective capacity of safety floors is unknown. The purpose of this study was to test whether safety floors provide greater impact attenuation compared with traditional flooring, and whether BMI and gender modify their impact attenuation properties. Thirty participants (7 men and 7 women of low BMI; 7 men and 9 women of high BMI) underwent lateral pelvis release trials on 2 common floors and 4 safety floors. As a group, the safety floors reduced peak force (by up to 11.7%), and increased the time to peak force (by up to 25.5%) compared with a traditional institutional grade floor. Force attenuation was significantly higher for the low BMI group, and for males. Force attenuation was greatest for the low BMI males, averaging 26.5% (SD = 3.0) across the safety floors. These findings demonstrate an overall protective effect of safety floors during lateral falls on the pelvis, but also suggest augmented benefits for frail older adults (often with low body mass) who are at an increased risk of hip fracture.
Deflection of Resilient Materials for Reduction of Floor Impact Sound
Lee, Jung-Yoon; Kim, Jong-Mun
2014-01-01
Recently, many residents living in apartment buildings in Korea have been bothered by noise coming from the houses above. In order to reduce noise pollution, communities are increasingly imposing bylaws, including the limitation of floor impact sound, minimum thickness of floors, and floor soundproofing solutions. This research effort focused specifically on the deflection of resilient materials in the floor sound insulation systems of apartment houses. The experimental program involved conducting twenty-seven material tests and ten sound insulation floating concrete floor specimens. Two main parameters were considered in the experimental investigation: the seven types of resilient materials and the location of the loading point. The structural behavior of sound insulation floor floating was predicted using the Winkler method. The experimental and analytical results indicated that the cracking strength of the floating concrete floor significantly increased with increasing the tangent modulus of resilient material. The deflection of the floating concrete floor loaded at the side of the specimen was much greater than that of the floating concrete floor loaded at the center of the specimen. The Winkler model considering the effect of modulus of resilient materials was able to accurately predict the cracking strength of the floating concrete floor. PMID:25574491
Deflection of resilient materials for reduction of floor impact sound.
Lee, Jung-Yoon; Kim, Jong-Mun
2014-01-01
Recently, many residents living in apartment buildings in Korea have been bothered by noise coming from the houses above. In order to reduce noise pollution, communities are increasingly imposing bylaws, including the limitation of floor impact sound, minimum thickness of floors, and floor soundproofing solutions. This research effort focused specifically on the deflection of resilient materials in the floor sound insulation systems of apartment houses. The experimental program involved conducting twenty-seven material tests and ten sound insulation floating concrete floor specimens. Two main parameters were considered in the experimental investigation: the seven types of resilient materials and the location of the loading point. The structural behavior of sound insulation floor floating was predicted using the Winkler method. The experimental and analytical results indicated that the cracking strength of the floating concrete floor significantly increased with increasing the tangent modulus of resilient material. The deflection of the floating concrete floor loaded at the side of the specimen was much greater than that of the floating concrete floor loaded at the center of the specimen. The Winkler model considering the effect of modulus of resilient materials was able to accurately predict the cracking strength of the floating concrete floor.
NASA Technical Reports Server (NTRS)
Kanemitsu, Yoichi; Watanabe, Katsuhide; Yano, Kenichi; Mizuno, Takayuki
1994-01-01
This paper introduces a study on an Electromagnetically Levitated Vibration Isolation System (ELVIS) for isolation control of large-scale vibration. This system features no mechanical contact between the isolation table and the installation floor, using a total of four electromagnetic actuators which generate magnetic levitation force in the vertical and horizontal directions. The configuration of the magnet for the vertical direction is designed to prevent any generation of restoring vibratory force in the horizontal direction. The isolation system is set so that vibration control effects due to small earthquakes can be regulated to below 5(gal) versus horizontal vibration levels of the installation floor of up t 25(gal), and those in the horizontal relative displacement of up to 30 (mm) between the floor and levitated isolation table. In particular, studies on the relative displacement between the installation floor and the levitated isolation table have been made for vibration control in the horizontal direction. In case of small-scale earthquakes (Taft wave scaled: max. 25 gal), the present system has been confirmed to achieve a vibration isolation to a level below 5 gal. The vibration transmission ratio of below 1/10 has been achieved versus continuous micro-vibration (approx. one gal) in the horizontal direction on the installation floor.
Floor cleaning: effect on bacteria and organic materials in hospital rooms.
Andersen, B M; Rasch, M; Kvist, J; Tollefsen, T; Lukkassen, R; Sandvik, L; Welo, A
2009-01-01
Routine surface cleaning is recommended to control the spread of pathogens in hospital environments. In Norway, ordinary cleaning of patient rooms is traditionally performed with soap and water. In this study, four floor-mopping methods--dry, spray, moist and wet mopping--were compared by two systems using adenosine triphosphate (ATP) bioluminescence (Hygiena and Biotrace). These systems assess residual organic soil on surfaces. The floor-mopping methods were also assessed by microbiological samples from the floor and air, before and after cleaning. All methods reduced organic material on the floors but wet and moist mopping seemed to be the most effective (P < 0.001, P < 0.011, respectively, ATP Hygiena). The two ATP methods were easy to use, although each had their own reading scales. Cleaning reduced organic material to 5-36% of the level present before cleaning, depending upon mopping method. All four mopping methods reduced bacteria on the floor from about 60-100 to 30-60 colony-forming units (cfu)/20cm2 floor. Wet, moist and dry mopping seemed to be more effective in reducing bacteria on the floor, than the spray mopping (P=0.007, P=0.002 and P=0.011, respectively). The burden of bacteria in air increased for all methods just after mopping. The overall best cleaning methods seemed to be moist and wet mopping.
Fisher, A.T.; Narasimhan, T.N.
1991-01-01
A two-dimensional, one by two-kilometer section through the seafloor was simulated with a numerical model to investigate coupled fluid and heat flow resulting from basalt intrusions in a buried spreading center. Boundary and initial conditions and physical properties of both sediments and basalt were constrained by field surveys and drilling in the Guaymas Basin, central Gulf of California. Parametric variations in these studies included sediment and basalt permeability, anisotropy in sediment permeability, and the size of heat sources. Faults were introduced through new intrusions both before and after cooling.Background heat input caused fluid convection at velocities ≤ 3 cm a−1 through shallow sediments. Eighty to ninety percent of the heat introduced at the base of the simulations exited through the upper, horizontal surface, even when the vertical boundaries were made permeable to fluid flow. The simulated injection of a 25–50 m thick basalt intrusion at a depth of 250 m resulted in about 10 yr of pore-fluid expulsion through the sea-floor in all cases, leaving the sediments above the intrusions strongly underpressured. A longer period of fluid recharge followed, sometimes accompanied by reductions in total seafloor heat output of 10% in comparison to pre-intrusion values. Additional discharge-recharge events were dispersed chaotically through the duration of the cooling period. These cycles in heat and fluid flow resulted from the response of the simulated system to a thermodynamic shock, the sudden emplacement of a large heat source, and not from mechanical displacement of sediments and pore fluids, which was not simulated.Water/rock mass ratios calculated from numerical simulations are in good agreement with geochemical estimates from materials recovered from the Guaymas Basin, assuming a bulk basalt permeability value of at least 10−17 m2/(10−2 mD). The addition of faults through intrusions and sediments in these simulations did not facilitate continuous, rapid venting. Increased heat input at the base of the faults resulted in temporarily greater fluid discharge, but the flow could not be sustained because the modeled system could not recharge cold fluid quickly enough to remove sufficient heat through the vents.
10 CFR 431.306 - Energy conservation standards and their effective dates.
Code of Federal Regulations, 2014 CFR
2014-01-01
..., ceiling, and door insulation of at least R-25 for coolers and R-32 for freezers, except that this... energy consumption; (4) Contain floor insulation of at least R-28 for freezers; (5) For evaporator fan... triple-pane glass with either heat-reflective treated glass or gas fill. (2) Transparent reach-in doors...
Simplified Floor-Area-Based Energy-Moisture-Economic Model for Residential Buildings
ERIC Educational Resources Information Center
Martinez, Luis A.
2009-01-01
In the United States, 21% of all energy is used in residential buildings (40% of which is for heating and cooling homes). Promising improvements in residential building energy efficiency are underway such as the Building America Program and the Passive House Concept. The ability of improving energy efficiency in buildings is enhanced by building…
Blood on the Gym Floor: Application of Universal Precautions
ERIC Educational Resources Information Center
Clark, Gary
2008-01-01
A student or an athlete bleeding does not mean that the teacher or coach is necessarily bad or irresponsible. Most have had students (probably from dry heat in the winter) who develop a nosebleed for no apparent reason. Obviously there are also physical activities and sports with a higher chance of physical contact, and thus potential for…
Goodbye, Orlando? Heat and Hot Issues, Theme Parks, and a Busy Show Floor
ERIC Educational Resources Information Center
Berry, John; Blumenstein, Lynn; DiMattia, Susan; Kenney, Brian; Oder, Norman; Rogers, Michael
2004-01-01
The American Library Association's (ALA) Annual Conference, June 24?30, in steamy Orlando, drew 19,575 people, including 5,739 exhibitors, the lowest total since Miami in 1994, not counting the SARS-shadowed conference in Toronto last year (see statistics, p. 15). Although this years conference was filled with exciting events, this abstract is…
Zhen, Xiaofei; Osman, Yassir Idris Abdalla; Feng, Rong; Si, Zetian
2018-01-01
Ample quantities of solar and local biomass energy are available in the rural regions of northwest China to satisfy the energy needs of farmers. In this work, low-temperature solar thermal collectors, photovoltaic solar power generators, and solar-powered thermostatic biogas digesters were combined to create a heat, electricity, and biogas cogeneration system and were experimentally studied through two buildings in a farming village in northwestern China. The results indicated that the floor heater had the best heating effect. And the fraction of the energy produced by the solar elements of the system was 60.3%. The photovoltaic power-generation system achieved photovoltaic (PV) conversion efficiencies of 8.3% and 8.1% during the first and second season, respectively. The intrinsic power consumption of the system was 143.4 kW·h, and 115.7 kW·h of electrical power was generated by the system in each season. The average volume of biogas produced daily was approximately 1.0 m3. Even though the ambient temperature reached −25°C, the temperature of the biogas digester was maintained at 27°C ± 2 for thermostatic fermentation. After optimization, the energy-saving rate improved from 66.2% to 85.5%. The installation reduced CO2 emissions by approximately 27.03 t, and the static payback period was 3.1 yr. Therefore, the system is highly economical, energy efficient, and beneficial for the environment. PMID:29862289
Kang, Jian; Li, Jinping; Zhen, Xiaofei; Osman, Yassir Idris Abdalla; Feng, Rong; Si, Zetian
2018-01-01
Ample quantities of solar and local biomass energy are available in the rural regions of northwest China to satisfy the energy needs of farmers. In this work, low-temperature solar thermal collectors, photovoltaic solar power generators, and solar-powered thermostatic biogas digesters were combined to create a heat, electricity, and biogas cogeneration system and were experimentally studied through two buildings in a farming village in northwestern China. The results indicated that the floor heater had the best heating effect. And the fraction of the energy produced by the solar elements of the system was 60.3%. The photovoltaic power-generation system achieved photovoltaic (PV) conversion efficiencies of 8.3% and 8.1% during the first and second season, respectively. The intrinsic power consumption of the system was 143.4 kW·h, and 115.7 kW·h of electrical power was generated by the system in each season. The average volume of biogas produced daily was approximately 1.0 m 3 . Even though the ambient temperature reached -25°C, the temperature of the biogas digester was maintained at 27°C ± 2 for thermostatic fermentation. After optimization, the energy-saving rate improved from 66.2% to 85.5%. The installation reduced CO 2 emissions by approximately 27.03 t, and the static payback period was 3.1 yr. Therefore, the system is highly economical, energy efficient, and beneficial for the environment.
Widespread Magmatism as a Result of Impact Related Decompression Melting on Early Mars
NASA Astrophysics Data System (ADS)
Edwards, C. S.; Bandfield, J. L.; Christensen, P. R.; Rogers, D.
2012-12-01
Flat-floored craters on Mars have been observed since early spacecraft viewed the surface. Early work characterized these craters as infilled by sedimentary materials [e.g. Christensen, 1983] but later work using THEMIS thermal inertia determined these craters contain some of the rockiest materials on the planet and not sedimentary materials [Edwards et al., 2009]. Here we investigate the distribution, physical properties (morphology and thermal inertia), and composition of these craters over the entire planet. We find the majority of rocky crater floors identified (~3300) are concentrated in the low albedo (0.1-0.17), cratered southern highlands. These craters are associated with the highest thermal inertia values (e.g. > 500 to 2000 J m-2 K-1 s-1/2), some of the most mafic materials on the planet (enriched in olivine/pyroxene vs. high-Si phases/plagioclase, often with >10-15% olivine areal abundance), and formed ~3.5 billion years ago. Based on the properties of the crater fill materials described, three mechanisms are considered for the formation of flat-floored, high thermal inertia crater floors on Mars including: 1) the lithification/induration of sediments, 2) the ponding of crustal melt material related to the heat generated during the impact process, and 3) infilling by volcanic materials. We find the only likely scenario is volcanic infilling through fractures created in the impact event. Furthermore, we find the generation of the primitive magma would be directly sourced from the decompression melting of the martian mantle due to the removal of several kilometers of overlying crustal material by the impactor. As the ancient martian crust was likely thin and the geothermal gradients were significantly higher than present day [e.g. Zuber, 2001], the decompression melting of the mantle [Bertka and Holloway, 1994] would be more likely to occur on early Mars then under present day conditions. This is borne out by the ancient ages (~3-4Ga) of the crater floors that indicates their formation early in martian history and not after the crustal thickening of the southern highlands and reduction of the geothermal gradient. Based on the distribution of these crater floors, we find that this process occurred over much of the surface of early Mars, during or shortly thereafter the Late Heavy Bombardment when the crust was still relatively thin and heat flow was high. We have shown that this process was widespread and ubiquitous, responsible for the eruption of significant volumes of primitive mantle material, both inside and outside of craters, and is an important planetary process that has gone previously undocumented. However, this process is likely not unique to Mars and while we have not examined other planetary bodies in detail, craters on Earth's moon and Mercury show distinctive morphologic similarities [e.g. Schultz, 1976] that suggest this process occurred throughout the early solar system on many rocky bodies. References: Bertka, C. M., et al. (1994), Contributions to Mineralogy and Petrology, 115(3), 313-322. Christensen, P. R. (1983), Icarus, 56(3), 496-518. Edwards, C. S., et al. (2009), J. Geophys. Res, 114, E11001. Schultz, P. H. (1976), The Moon, 15, 241-273. Zuber, M. T. (2001), Nature, 412, 220-227.
Structure-borne sound from magnetic resonance imaging systems
NASA Astrophysics Data System (ADS)
Ungar, Eric E.; Zapfe, Jeffrey A.
2003-10-01
Magnetic resonance imaging (MRI) systems are known to produce a considerable amount of audible noise. The recent tendency to install such systems on above-grade floors has led to increasing concerns about structure-borne noise transmission from the MRI to adjacent occupied areas. This paper presents the results of a study in which structure-borne noise forces produced by two operational MRI systems were determined via measurement of the floor vibrations induced by the systems and of the impedance of their supporting floors. Forces with known spectra were applied to the floors of planned MRI suites in a hospital extension and the corresponding noise in adjacent areas was measured. Similarly, airborne noise was introduced in the planned suites and the related noise in adjacent areas was measured. The results then were scaled to correspond to the measured MRI forces and airborne noise. It was found that in areas below the planned MRI installations structure-borne noise would predominate, unless it is mitigated. Structure-borne noise isolation of MRI systems, whose environments must meet stringent vibration criteria, is discussed briefly.
Gettings, M.E.
1982-01-01
The heat-flow profile across the Arabian Shield from Ar Riyad to Ad Darb and across the Red Sea is examined for compatibility with the lithospheric structure of the area as deduced from geologic and other geophysical data. Broad continental uplift associated with Red Sea rifting is symmetric about the Red Sea axis, and geologic and geochronologic evidence indicate that uplift has occurred mainly in the interval 25-13 Ma (mega-annum) ago. Thermal-profile changes in the upper mantle resulting from an influx of hot material associated with rifting yield the correct order of magnitude of uplift, and this mechanism is suggested as the explanation for the regional doming. A lithospheric section, constructed from seismic refraction, gravity, and regional geologic data, provides the framework for construction of thermal models. Thermal gradient measurements were made in drill holes at five shot points. Geotherms for the Shield, which assume a radiogenic heat-source distribution that decreases exponentially with depth, yield temperatures of about 450?C at a depth of 40 km (base of the crust) for shot points 2 (Sabhah) and 3. The geotherm for shot point 4 (near Bishah) yields a distinctly higher temperature (about 580?C) for the same depth. Static models used to model the heat flow in the oceanic crust of the Red Sea shelf and coastal plain either yield too small a heat flow to match the observed heat flow or give lithosphere thicknesses that are so thin as to be improbable. Dynamic (solid-state accretion) models, which account for mantle flow at the base of the lithosphere, adequately match the observed heat-flow values. In the deep-water trough of the Red Sea, which is presently undergoing active sea-floor spreading, classical models of heat flow for a moving slab with accretion at the spreading center are adequate to explain the average heat-flow level. At shot point 5 (Ad Darb), the anomalous heat flow of 2 HFU (heat-flow units) can be explained in terms of a Shield component (0.8-1.0 HFU) and a component related to heating by the abutting oceanic crust a few kilometers away for periods exceeding 10 Ma. Analytical results are included for: 1) the cooling of a static sheet with an initial temperature distribution characteristic of a moving slab in a sea-floor spreading environment, and 2) the heating of a homogeneous quarter-space at its vertical boundary.
Bhan, Shivam; Levine, Iris C; Laing, Andrew C
2014-07-18
Impact mechanics theory suggests that peak loads should decrease with increase in system energy absorption. In light of the reduced hip fracture risk for persons with high body mass index (BMI) and for falls on soft surfaces, the purpose of this study was to characterize the effects of participant BMI, gender, and flooring surface on system energy absorption during lateral falls on the hip with human volunteers. Twenty university-aged participants completed the study with five men and five women in both low BMI (<22.5 kg/m(2)) and high BMI (>27.5 kg/m(2)) groups. Participants underwent lateral pelvis release experiments from a height of 5 cm onto two common floors and four safety floors mounted on a force plate. A motion-capture system measured pelvic deflection. The energy absorbed during the initial compressive phase of impact was calculated as the area under the force-deflection curve. System energy absorption was (on average) 3-fold greater for high compared to low BMI participants, but no effects of gender were observed. Even after normalizing for body mass, high BMI participants absorbed 1.8-fold more energy per unit mass. Additionally, three of four safety floors demonstrated significantly increased energy absorption compared to a baseline resilient-rolled-sheeting system (% increases ranging from 20.7 to 28.3). Peak system deflection was larger for high BMI persons and for impacts on several safety floors. This study indicates that energy absorption may be a common mechanism underlying the reduced risk of hip fracture for persons with high BMI and for those who fall on soft surfaces. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.
Measurements of carbonyls in a 13-story building.
Báez, Armando P; Padilla, Hugo G; García, Rocío M; Belmont, Raúl D; Torres, Maria del Carmen B
2004-01-01
Formaldehyde and acetaldehyde are emitted by many mobile and stationary sources and secondary aldehydes are intermediates in the photo-oxidation of organic compounds in the atmosphere. These aldehydes are emitted indoors by many materials such as furniture, carpets, heating and cooling systems, an by smoking. Carbonyls, mainly formaldehyde and acetaldehyde, have been studied because of their adverse health effects. In addition, formaldehyde is a suspected carcinogen. Therefore, the concentrations of formaldehyde and acetaldehyde were determined to assess the inhalation exposure doses to carbonyls for people who work in a 13-story building and in order to evaluate the cancer hazard. Carbonyl compounds in indoor and outdoor air were measured at a 13-story building located in Mexico City. The mezzanine, fifth and tenth floors, and the third level-parking garage were selected for sampling. Samples were collected in two sampling periods, the first from April 20 to 29, 1998 and the second from December 1 to 20, 1998. Carbonyls were sampled by means of DNHP-coated cartridges at a flow rate of 1 l min(-1) from 9:00 to 19:00 hours, during 2-hour time intervals and analyzed by HPLC with hours, during 2-hour time intervals and analyzed by HPLC with UV/VIS detection. Mean carbonyl concentrations were highest in the 3rd level-parking garage, with the formaldehyde concentration being the highest ranging from 108 to 418 microg m(-3). In working areas, the highest carbonyl arithmetic mean concentrations (AM) were observed on the 5th floor. Acetone and formaldehyde concentrations were highest in April ranging from 161 to 348 microg m(-3) (AM = 226) and from 157 to 270 microg m(-3) (AM = 221), respectively. Propionaldehyde and butyraldehyde were present in smaller concentrations ranging from 2 to 25 and 1 to 28 microg m(-3), respectively, considering all the samples. Mean indoor/outdoor ratios of carbonyls ranged from 1.8 to 9.6. A reduction of inhalation exposure doses of 41% and 45% was observed in the fifth floor air after the air conditioning systems had been repaired. Formaldehyde and acetaldehyde concentrations were higher in smoking environments. Indoor carbonyl concentrations were significantly greater than outdoor concentrations. Tobacco smoke seems to be the main indoor source of formaldehyde. After the air conditioning system was maintained and repaired (as was recommended), an important reduction in the emission of formaldehyde and acetaldehyde was achieved on all floors, except for the 3rd level parking garage, thereby reducing the inhalation exposure doses. The results obtained in this research demonstrated that maintenance of air conditioning systems must be carried out regularly in order to avoid possible adverse effects on health. Additionally, it is mandatory that isolated smoking areas, with air extraction systems, be installed in every public building.
NASA Astrophysics Data System (ADS)
Ghafar, NH Abd; Sahban, N. M.
2017-11-01
This research was conducted on 2 m LVL - concrete composite (LCC) floor consisting of two parts between concrete floor and laminated veneer lumber (LVL) timber joist. The floor system was model using SAP 2000 software package. The aim of this research to study the vibration behaviour of the LCC floor with different concrete topping thickness which 25 mm, 65 mm and from 20 mm until 200 mm in every 20 mm interval. Natural frequency decision produced through SAP 2000 in thickness 25 mm and 65 mm is 57.45 Hz and 57.19 Hz. In thickness from 20 mm until 200 mm in every 20 mm interval, optimum value which found is during thickness reach 65 mm. For concrete topping below 65 mm thickness, the mass will be domain the behavior of the floor. When concrete topping increased more than 65 mm, the behavior of the floor will be domain by floor stiffness.
[Emergency medicine after a catastrophic disaster: from a view of geriatrics and gerontology].
Okinaga, Shoji; Daito, Hisayoshi; Suzuki, Motoi; Shiihara, Jun; Arai, Hiroyuki
2013-06-01
The megathrust earthquake and the towering tsunami hit the east coast of Japan on March 11th of 2011 after intervals of 1,142 years. About 90 % of nearly 20,000 victims were drowned in devastating waves, while every town and city along the coast turned out to be a ruin. Over 400,000 people were forced to move to the evacuation centers where the evacuees slept on the floor without electricity, running water or heating systems at freezing nights. Emergency medicine, therefore, was more required during the evacuation phase than during the acute phase of the tsunami disaster. Here discussed is the phenomenon that the events happened mostly to the elderly evacuees especially in the swept area by silty polluted seawater.
NASA Astrophysics Data System (ADS)
Stucker, V. K.; Tivey, M.; Lupton, J. E.; Walker, S. L.; Fornari, D. J.; de Ronde, C. E. J.
2014-12-01
Lake Rotomahana (North Island, New Zealand) is a crater lake with prominent hydrothermal venting. Water column studies were conducted in 2011 and 2014 to complement magnetic, seismic, bathymetric and heat flux surveys, respectively. Results from the heat flow survey indicate that Lake Rotomahana is getting warmer relative to historic measurements, with individual stations within the lake releasing heat in excess of 60 Watts/m2. Helium sources are found at the lake floor at depths of ~50 meters and ~100m. Helium concentrations below 50 m depth have increased with high statistical significance over the three years between surveys and represent some of the highest concentrations ever measured at 6x107 ccSTP/g with an end-member 3He/4He value of 7.1 Ra. Hydrothermal activity comprises a significant portion of the inputs to Lake Rotomahana, as evidenced by δD and δ18O values, as well as ratios of conservative elements such as boron and chloride. Waters collected from lakeshore hot springs show geographic differences in geothermal source temperature using a Na-K geothermometer, with inferred reservoir temperatures ranging from 200 to 230°C. Lake Rotomahana was in part the focus of the 1886 Tarawera eruption; our results show both pre-eruption hydrothermal sites and newly created post-eruption sites are active and should be monitored for continued changes.
Light-frame wall and floor systems : analysis and performance
G. Sherwood; R. C. Moody
1989-01-01
This report describes methods of predicting the performance of light-frame wood structures with emphasis on floor and wall systems. Methods of predicting structural performance, fire safety, and environmental concerns including thermal, moisture, and acoustic performance are addressed in the three major sections.
Hydrothermal systems on Mars: an assessment of present evidence
NASA Technical Reports Server (NTRS)
Farmer, J. D.
1996-01-01
Hydrothermal processes have been suggested to explain a number of observations for Mars, including D/H ratios of water extracted from Martian meteorites, as a means for removing CO2 from the Martian atmosphere and sequestering it in the crust as carbonates, and as a possible origin for iron oxide-rich spectral units on the floors of some rifted basins (chasmata). There are numerous examples of Martian channels formed by discharges of subsurface water near potential magmatic heat sources, and hydrothermal processes have also been proposed as a mechanism for aquifer recharge needed to sustain long term erosion of sapping channels. The following geological settings have been identified as targets for ancient hydrothermal systems on Mars: channels located along the margins of impact crater melt sheets and on the slopes of ancient volcanoes; chaotic and fretted terranes where shallow subsurface heat sources are thought to have interacted with ground ice; and the floors of calderas and rifted basins (e.g. chasmata). On Earth, such geological environments are often a locus for hydrothermal mineralization. But we presently lack the mineralogical information needed for a definitive evaluation of hypotheses. A preferred tool for identifying minerals by remote sensing methods on Earth is high spatial resolution, hyperspectral, near-infrared spectroscopy, a technique that has been extensively developed by mineral explorationists. Future efforts to explore Mars for ancient hydrothermal systems would benefit from the application of methods developed by the mining industry to look for similar deposits on Earth. But Earth-based exploration models must be adapted to account for the large differences in the climatic and geological history of Mars. For example, it is likely that the early surface environment of Mars was cool, perhaps consistently below freezing, with the shallow portions of hydrothermal systems being dominated by magma-cryosphere interactions. Given the smaller gravitational field, declining atmospheric pressure, and widespread, permeable megaregolith on Mars, volatile outgassing and magmatic cooling would have been more effective than on Earth. Thus, hydrothermal systems are likely to have had much lower average surface temperatures than comparable geological settings on Earth. The likely predominance of basaltic crust on Mars suggests that hydrothermal fluids and associated deposits should be enriched in Fe, Mg, Si and Ca, with surficial deposits being dominated by lower temperature, mixed iron oxide and carbonate mineralogies.
Hydrothermal systems on Mars: an assessment of present evidence.
Farmer, J D
1996-01-01
Hydrothermal processes have been suggested to explain a number of observations for Mars, including D/H ratios of water extracted from Martian meteorites, as a means for removing CO2 from the Martian atmosphere and sequestering it in the crust as carbonates, and as a possible origin for iron oxide-rich spectral units on the floors of some rifted basins (chasmata). There are numerous examples of Martian channels formed by discharges of subsurface water near potential magmatic heat sources, and hydrothermal processes have also been proposed as a mechanism for aquifer recharge needed to sustain long term erosion of sapping channels. The following geological settings have been identified as targets for ancient hydrothermal systems on Mars: channels located along the margins of impact crater melt sheets and on the slopes of ancient volcanoes; chaotic and fretted terranes where shallow subsurface heat sources are thought to have interacted with ground ice; and the floors of calderas and rifted basins (e.g. chasmata). On Earth, such geological environments are often a locus for hydrothermal mineralization. But we presently lack the mineralogical information needed for a definitive evaluation of hypotheses. A preferred tool for identifying minerals by remote sensing methods on Earth is high spatial resolution, hyperspectral, near-infrared spectroscopy, a technique that has been extensively developed by mineral explorationists. Future efforts to explore Mars for ancient hydrothermal systems would benefit from the application of methods developed by the mining industry to look for similar deposits on Earth. But Earth-based exploration models must be adapted to account for the large differences in the climatic and geological history of Mars. For example, it is likely that the early surface environment of Mars was cool, perhaps consistently below freezing, with the shallow portions of hydrothermal systems being dominated by magma-cryosphere interactions. Given the smaller gravitational field, declining atmospheric pressure, and widespread, permeable megaregolith on Mars, volatile outgassing and magmatic cooling would have been more effective than on Earth. Thus, hydrothermal systems are likely to have had much lower average surface temperatures than comparable geological settings on Earth. The likely predominance of basaltic crust on Mars suggests that hydrothermal fluids and associated deposits should be enriched in Fe, Mg, Si and Ca, with surficial deposits being dominated by lower temperature, mixed iron oxide and carbonate mineralogies.
9. Detail of pin truss and floor board system, from ...
9. Detail of pin truss and floor board system, from Minnesota end of the bridge, looking at the bridge's southwest side - Enloe Bridge No. 90021, Spanning Red River of North between Minnesota & North Dakota on County State Aid Highway 28, Wolverton, Wilkin County, MN
Wagenlehner, Florian Martin Erich; Fröhlich, Oliver; Bschleipfer, Thomas; Weidner, Wolfgang; Perletti, Gianpaolo
2014-06-01
Anatomical damage to pelvic floor structures may cause multiple symptoms. The Integral Theory System Questionnaire (ITSQ) is a holistic questionnaire that uses symptoms to help locate damage in specific connective tissue structures as a guide to reconstructive surgery. It is based on the integral theory, which states that pelvic floor symptoms and prolapse are both caused by lax suspensory ligaments. The aim of the present study was to psychometrically validate the ITSQ. Established psychometric properties including validity, reliability, and responsiveness were considered for evaluation. Criterion validity was assessed in a cohort of 110 women with pelvic floor dysfunctions by analyzing the correlation of questionnaire responses with objective clinical data. Test-retest was performed with questionnaires from 47 patients. Cronbach's alpha and "split-half" reliability coefficients were calculated for inner consistency analysis. Psychometric properties of ITSQ were comparable to the ones of previously validated Pelvic Floor Questionnaires. Face validity and content validity were approved by an expert group of the International Collaboration of Pelvic Floor surgeons. Convergent validity assessed using Bayesian method was at least as accurate as the expert assessment of anatomical defects. Objective data measurement in patients demonstrated significant correlations with ITSQ domains fulfilling criterion validity. Internal consistency values ranked from 0.85 to 0.89 in different scenarios. The ITSQ proofed accurate and is able to serve as a holistic Pelvic Floor Questionnaire directing symptoms to site-specific pelvic floor reconstructive surgery.
Evaluation of Production Processes to Identify Essential Equipment
1986-06-01
of Severe Dmae AMRed Sevre DUMP Suultlvity Drop Ht Imfpat vel Drap Ht Impact Val (ft) (ft/see) (ft) (ft/see) High 0.75 7 6 20 Normal 1.5 10 14 30 Low...below and overhead shnuld not contain any major structural defects . V-35 S. •. .’,’,....,, ,.- ./ ’•’ % .. ,. •/•/. .. /.: ... /.’•.,,..,•..,’’./ ¢.€ 3...included as one of the floor systems listed herein. 4. The floor system must have no serious structural defects . 5. The floor-to-ceiling height mat not
The deep structure of a sea-floor hydrothermal deposit
Zierenberg, R.A.; Fouquet, Y.; Miller, D.J.; Bahr, J.M.; Baker, P.A.; Bjerkgard, T.; Brunner, C.A.; Duckworth, R.C.; Gable, R.; Gieskes, J.; Goodfellow, W.D.; Groschel-Becker, H. M.; Guerin, G.; Ishibashi, J.; Iturrino, G.; James, R.H.; Lackschewitz, K.S.; Marquez, L.L.; Nehlig, P.; Peter, J.M.; Rigsby, C.A.; Schultheiss, P.; Shanks, Wayne C.; Simoneit, B.R.T.; Summit, M.; Teagle, D.A.H.; Urbat, M.; Zuffa, G.G.
1998-01-01
Hydrothermal circulation at the crests of mid-ocean ridges plays an important role in transferring heat from the interior of the Earth. A consequence of this hydrothermal circulation is the formation of metallic ore bodies known as volcanic-associated massive sulphide deposits. Such deposits, preserved on land, were important sources of copper for ancient civilizations and continue to provide a significant source of base metals (for example, copper and zinc). Here we present results from Ocean Drilling Program Leg 169, which drilled through a massive sulphide deposit on the northern Juan de Fuca spreading centre and penetrated the hydrothermal feeder zone through which the metal-rich fluids reached the sea floor. We found that the style of feeder-zone mineralization changes with depth in response to changes in the pore pressure of the hydrothermal fluids and discovered a stratified zone of high-grade copper-rich replacement mineralization below the massive sulphide deposit. This copper-rich zone represents a type of mineralization not previously observed below sea-floor deposits, and may provide new targets for land-based mineral exploration.
Exclusive queueing model including the choice of service windows
NASA Astrophysics Data System (ADS)
Tanaka, Masahiro; Yanagisawa, Daichi; Nishinari, Katsuhiro
2018-01-01
In a queueing system involving multiple service windows, choice behavior is a significant concern. This paper incorporates the choice of service windows into a queueing model with a floor represented by discrete cells. We contrived a logit-based choice algorithm for agents considering the numbers of agents and the distances to all service windows. Simulations were conducted with various parameters of agent choice preference for these two elements and for different floor configurations, including the floor length and the number of service windows. We investigated the model from the viewpoint of transit times and entrance block rates. The influences of the parameters on these factors were surveyed in detail and we determined that there are optimum floor lengths that minimize the transit times. In addition, we observed that the transit times were determined almost entirely by the entrance block rates. The results of the presented model are relevant to understanding queueing systems including the choice of service windows and can be employed to optimize facility design and floor management.
Bergsten, Christer; Telezhenko, Evgenij; Ventorp, Michael
2015-01-01
Simple Summary In this study the effect of different flooring systems on locomotion, claw conformation, loading, claw- and leg disorders was assessed in heifers from one year before to one year after calving. After calving, heifers kept on alleys covered with rubber flooring were found to develop less lameness, fewer claw disorders of the sole horn and fewer leg lesions than those kept on concrete alleys. Recruitment heifers reared on soft deep straw bedding had fewer sole horn lesions and more overgrown claws before calving, but were more prone to severe sole horn lesions after calving, than those reared in cubicles with hard concrete floors. Abstract Claw health, an important dairy cow welfare parameter, may be affected by early-life foot/leg stresses. To investigate this, groups of pregnant heifers were allocated to deep straw bedding (Soft) or cubicles (Hard), both with scraped concrete feeding alleys. After the grazing season, they were re-housed in cubicle systems, half on slatted concrete (Hard) and half on slatted rubber (Soft) alleys. Claw measurements, contact area and pressure distribution claw/flooring, claw disorders and leg lesions were recorded at the start and end of each housing season. Locomotion and leg lesions were also scored monthly after calving. Prevalence of sole haemorrhages was higher among pregnant heifers in cubicles than in deep straw. After calving, first-calvers on Hard floors had higher odds for lameness (OR = 3.6; p < 0.01), sole haemorrhages/ulcers (OR = 2.2; p < 0.05), white-line haemorrhages (OR = 2.8; p < 0.01) and leg lesions (OR = 2.6; p < 0.02) than those on Soft floors. Lowest prevalence and severity of sole and white-line haemorrhages (non-significant) in first-calvers was found in those on Soft floors and reared on Hard floors and the highest prevalence and severity on those on Hard floors reared on Soft floors. Soft flooring after calving is of most importance for healthy feet and legs. PMID:26479380
NASA Astrophysics Data System (ADS)
Norini, G.; Groppelli, G.; Sulpizio, R.; Carrasco-Núñez, G.; Dávila-Harris, P.; Pellicioli, C.; Zucca, F.; De Franco, R.
2015-08-01
The Los Humeros Volcanic Complex (LHVC) is an important geothermal target in the Trans-Mexican Volcanic Belt. Understanding the structure of the LHVC and its influence on the occurrence of thermal anomalies and hydrothermal fluids is important to get insights into the interplay between the volcano-tectonic setting and the characteristics of the geothermal resources in the area. In this study, we present a structural analysis of the LHVC, focused on Quaternary tectonic and volcano-tectonic features, including the areal distribution of monogenetic volcanic centers. Morphostructural analysis and structural field mapping revealed the geometry, kinematics and dynamics of the structural features in the study area. Also, thermal infrared remote sensing analysis has been applied to the LHVC for the first time, to map the main endogenous thermal anomalies. These data are integrated with newly proposed Unconformity Bounded Stratigraphic Units, to evaluate the implications for the structural behavior of the caldera complex and geothermal field. The LHVC is characterized by a multistage formation, with at least two major episodes of caldera collapse: Los Humeros Caldera (460 ka) and Los Potreros Caldera (100 ka). The study suggests that the geometry of the first collapse recalls a trap-door structure and impinges on a thick volcanic succession (10.5-1.55 Ma), now hosting the geothermal reservoir. The main ring-faults of the two calderas are buried and sealed by the widespread post-calderas volcanic products, and for this reason they probably do not have enough permeability to be the main conveyers of the hydrothermal fluid circulation. An active, previously unrecognized fault system of volcano-tectonic origin has been identified inside the Los Potreros Caldera. This fault system is the main geothermal target, probably originated by active resurgence of the caldera floor. The active fault system defines three distinct structural sectors in the caldera floor, where the occurrence of hydrothermal fluids is controlled by fault-induced secondary permeability. The resurgence of the caldera floor could be induced by an inferred magmatic intrusion, representing the heat source of the geothermal system and feeding the simultaneous monogenetic volcanic activity around the deforming area. The operation of the geothermal field and the plans for further exploration should focus on, both, the active resurgence fault system and the new endogenous thermal anomalies mapped outside the known boundaries of the geothermal field.
Sally M. Haase; Stephen S. Sackett
1998-01-01
Many national parks have incorporated the use of management-ignited prescribed fire in their management plans. Soil and cambium heating, forest floor fuel reduction, and soil nutrient increases have been measured on eight independent, planned management fires over a 9-year period in Sequoia and Kings Canyon National Parks. Findings show that instantaneous lethal...
Code of Federal Regulations, 2011 CFR
2011-01-01
... concrete, usually reinforced, poured over gravel and a vapor barrier with perimeter insulation to prevent heat loss. 4. Subflooring 0 1 1 The installation of materials used for flooring that is laid directly..., and before the insulation is placed in the walls and ceiling. 14. Insulation 2 2 2 The installation of...
Code of Federal Regulations, 2010 CFR
2010-01-01
... concrete, usually reinforced, poured over gravel and a vapor barrier with perimeter insulation to prevent heat loss. 4. Subflooring 0 1 1 The installation of materials used for flooring that is laid directly..., and before the insulation is placed in the walls and ceiling. 14. Insulation 2 2 2 The installation of...
Code of Federal Regulations, 2012 CFR
2012-01-01
... concrete, usually reinforced, poured over gravel and a vapor barrier with perimeter insulation to prevent heat loss. 4. Subflooring 0 1 1 The installation of materials used for flooring that is laid directly..., and before the insulation is placed in the walls and ceiling. 14. Insulation 2 2 2 The installation of...
Code of Federal Regulations, 2013 CFR
2013-01-01
... concrete, usually reinforced, poured over gravel and a vapor barrier with perimeter insulation to prevent heat loss. 4. Subflooring 0 1 1 The installation of materials used for flooring that is laid directly..., and before the insulation is placed in the walls and ceiling. 14. Insulation 2 2 2 The installation of...
Code of Federal Regulations, 2014 CFR
2014-01-01
... concrete, usually reinforced, poured over gravel and a vapor barrier with perimeter insulation to prevent heat loss. 4. Subflooring 0 1 1 The installation of materials used for flooring that is laid directly..., and before the insulation is placed in the walls and ceiling. 14. Insulation 2 2 2 The installation of...
European Foundation Designs for Seasonally Frozen Ground
1992-03-01
104 173. Design thermal conductivity of mineral wool for frost protection...inside of theo - foundation wall, consisted of 50 mm of Rockwool o3 wallo -"o 0 ° (a mineral wool ). This insulation guides heat from the house down...Thermal Insulation Laboratory 1982.) by introducing mineral wool (Fig. 49c) gives a Table 4. Relationship between floor surface tempera- further slight
Asbestos Workshop: Sampling, Analysis, and Risk Assessment
2012-03-01
coatings Vinyl/asbestos floor tile Automatic transmission components Clutch facings Disc brake pads Drum brake linings Brake blocks Commercial and...A naturally-occurring pliant and fibrous mineral with heat-resistant properties • Serpentine Class: joint compound,‘popcorn’ceilings, brake pads...fabrics, and is used in fire-resistant and insulating materials such as brake linings. The asbestos minerals include chrysotile (white asbestos) and
16. Interior view, greenhouse, south wall taken from the ground. ...
16. Interior view, greenhouse, south wall taken from the ground. The original floor height is indicated by the joists on the left. The large opening on the right was formerly fitted with an exterior-fed iron stove used to heat the space on particularly cold days. - John Bartram House & Garden, Greenhouse, 54th Street & LIndbergh Boulevard, Philadelphia, Philadelphia County, PA
Code of Federal Regulations, 2013 CFR
2013-04-01
... under the HUD building product standard and certification program for construction adhesives for wood... program for construction adhesives for wood floor systems. (a) Applicable standards. (1) All construction adhesives for field glued wood floor systems shall be designed, manufactured, and tested in compliance with...
Code of Federal Regulations, 2014 CFR
2014-04-01
... under the HUD building product standard and certification program for construction adhesives for wood... program for construction adhesives for wood floor systems. (a) Applicable standards. (1) All construction adhesives for field glued wood floor systems shall be designed, manufactured, and tested in compliance with...
11. UNDERSIDE, VIEW PERPENDICULAR TO PIERS, SHOWING FLOOR SYSTEM OBLIQUELY ...
11. UNDERSIDE, VIEW PERPENDICULAR TO PIERS, SHOWING FLOOR SYSTEM OBLIQUELY AND NORTH PIER. LOOKING NORTH. - Route 31 Bridge, New Jersey Route 31, crossing disused main line of Central Railroad of New Jersey (C.R.R.N.J.) (New Jersey Transit's Raritan Valley Line), Hampton, Hunterdon County, NJ
10. UNDERSIDE, VIEW PARALLEL TO BRIDGE, SHOWING FLOOR SYSTEM AND ...
10. UNDERSIDE, VIEW PARALLEL TO BRIDGE, SHOWING FLOOR SYSTEM AND SOUTH PIER. LOOKING SOUTHEAST. - Route 31 Bridge, New Jersey Route 31, crossing disused main line of Central Railroad of New Jersey (C.R.R.N.J.) (New Jersey Transit's Raritan Valley Line), Hampton, Hunterdon County, NJ
Code of Federal Regulations, 2010 CFR
2010-04-01
... under the HUD building product standard and certification program for construction adhesives for wood... program for construction adhesives for wood floor systems. (a) Applicable standards. (1) All construction adhesives for field glued wood floor systems shall be designed, manufactured, and tested in compliance with...
INTERIOR SECOND FLOOR EAST ENGINEERING DESIGN AREA DETAIL VIEW, FACING ...
INTERIOR SECOND FLOOR EAST ENGINEERING DESIGN AREA DETAIL VIEW, FACING NORTH. - NASA Industrial Plant, Systems Integration & Checkout Facility, 12214 Lakewood Boulevard, Downey, Los Angeles County, CA
In-ground optical fibre Bragg grating pressure switch for security applications
NASA Astrophysics Data System (ADS)
Allwood, Gary; Wild, Graham; Hinckley, Steven
2012-02-01
In this study, a fibre Bragg grating (FBG) was embedded beneath three common flooring materials acting as a pressure switch for in-ground intrusion detection. This is achieved using an intensiometric detection system, where a laser diode and FBG were optically mismatched so that there was a static dc offset from the transmitted and reflected optical power signals. As pressure was applied, in the form of a footstep, a strain induced wavelength shift occurred that could then be detected by converting the wavelength shift into an intensity change. The change in intensity caused a significant change in the DC offset which behaved as on optical switch. This switch could easily be configured to trigger an alarm if required. The intention is to use the FBG sensor as an in-ground intrusion detection pressure switch to detect an intruder walking within range of the sensor. This type of intrusion detection system can be applied to both external (in soil, etc) and internal (within the foundations or flooring of the home) security systems. The results show that a person's footstep can clearly be detected through solid wood flooring, laminate flooring, and ceramic floor tiles.
Grenne, Tor; Slack, John F.
2003-01-01
The jaspers are interpreted to record colloidal fallout from one or more hydrothermal plumes, followed by maturation (ageing) of an Si-Fe-oxyhydroxide gel, on and beneath the Ordovician sea floor. Small hematitic filaments in the jaspers reflect bacteria-catalysed oxidation of Fe2+ within the plume. The larger tubular filaments resulted from either microbial activity or inorganic self-organized mineral growth of Fe-oxyhydroxide within the Si-Fe-oxyhydroxide gel after deposition on the sea floor, prior to more advanced maturation of the gel as represented by the spheroidal and botryoidal silica-hematite textures. Bleaching and hematite±epidote growth are interpreted to reflect heat and fluids generated during deposition of basaltic sheet flows on top of the gels.
The influence of novel compliant floors on balance control in elderly women--A biomechanical study.
Wright, Alexander D; Laing, Andrew C
2011-07-01
Novel compliant floors aim to decrease the risk for fall-related injury by providing substantial force attenuation during the impact phase of falls. Certain models of compliant flooring have been shown to have limited influence on postural sway and successful completion of dynamic balance tasks. However, the effects of these products on balance recovery mechanisms following an externally induced perturbation have yet to be quantified. We used a floor translation paradigm to induce a balance perturbation to thirteen elderly community-dwelling women. Outcome measures included the displacement rates and margins of safety for both the underfoot centre-of-pressure and whole-body centre-of-mass across two novel compliant floors (SmartCell, SofTile), two basic foam surfaces (Firm-Foam, Soft-Foam) and a standard 'Rigid' floor as a control condition. The centre-of-mass and centre-of-pressure margins of safety, and all centre-of-mass displacement rates, were not significantly lower for the two novel compliant flooring systems compared to the control floor. The centre-of-pressure displacement rates were similar to the control floor for the SmartCell floor condition. The majority of the margin of safety and displacement rate variables for the foam floors were significantly lower than the control condition. This study illustrates that the SmartCell and SofTile novel compliant floors have minimal influences on balance and balance control responses following externally induced perturbations in older community-dwelling women, and supports pilot installations of these floors to inform decisions regarding the development of clinical trials. Crown Copyright © 2011. Published by Elsevier Ltd. All rights reserved.
The influence of novel compliant floors on balance control in elderly women—A biomechanical study
Wright, Alexander D.; Laing, Andrew C.
2012-01-01
Novel compliant floors aim to decrease the risk for fall-related injury by providing substantial force attenuation during the impact phase of falls. Certain models of compliant flooring have been shown to have limited influence on postural sway and successful completion of dynamic balance tasks. However, the effects of these products on balance recovery mechanisms following an externally induced perturbation have yet to be quantified. We used a floor translation paradigm to induce a balance perturbation to thirteen elderly community-dwelling women. Outcome measures included the displacement rates and margins of safety for both the underfoot centre-of-pressure and whole-body centre-of-mass across two novel compliant floors (Smart-Cell, SofTile), two basic foam surfaces (Firm-Foam, Soft-Foam) and a standard ‘Rigid’ floor as a control condition. The centre-of-mass and centre-of-pressure margins of safety, and all centre-of-mass displacement rates, were not significantly lower for the two novel compliant flooring systems compared to the control floor. The centre-of-pressure displacement rates were similar to the control floor for the SmartCell floor condition. The majority of the margin of safety and displacement rate variables for the foam floors were significantly lower than the control condition. This study illustrates that the SmartCell and SofTile novel compliant floors have minimal influences on balance and balance control responses following externally induced perturbations in older community-dwelling women, and supports pilot installations of these floors to inform decisions regarding the development of clinical trials. PMID:21545881
Latimer, Nicholas; Dixon, Simon; Drahota, Amy Kim; Severs, Martin
2013-09-01
hospital falls place a substantial burden on healthcare systems. There has been limited research into the use of hospital flooring as an intervention against fall-related injuries. to assess the cost-effectiveness of shock-absorbing flooring compared with standard hospital flooring in hospital wards for older people. a cost-utility analysis was undertaken drawing upon data collected in a pilot cluster randomised controlled trial and the wider literature. the trial included eight hospital sites across England. Four sites installed shock-absorbing flooring in one bay, and four maintained their standard flooring. falls and resulting injuries and treatment were reported by hospital staff. Data on destination of discharge were collected. Patients were followed up at 3 months and further resource use data were collected. Health-related quality of life was assessed, allowing quality-adjusted life years (QALYs) to be estimated. The incremental cost-effectiveness ratio of the shock-absorbing flooring was assessed compared with the standard hospital flooring. in the base case, the shock-absorbing flooring was cost saving, but generated QALY losses due to an increase in the faller rate reported in the intervention arm. Scenario analysis showed that if the shock-absorbing flooring does not increase the faller rate it is likely to represent a dominant economic strategy-generating cost savings and QALY gains. the shock-absorbing flooring intervention has the potential to be cost-effective but further research is required on whether the intervention flooring results in a higher faller rate than standard flooring.
The Medusa Sea Floor Monitoring System
NASA Astrophysics Data System (ADS)
Flynn, F. T.; Schultz, A.; Gupta, M.; Powers, L.; Klinkhammer, G.
2004-12-01
The Medusa Sea Floor Monitoring System (MSMS) is a technology development project that is designed to enable fundamental research into understanding the potential for and limits to chemolithoautotrophic life. This is life within which inorganic carbon is converted to organic carbon and where only inorganic compounds serve as electron acceptors and electron donors. Such life forms are postulated to be capable of surviving in a Europan ocean. If we can prove that such life forms exist on Earth it would provide credence to the hypothesis that they might exist on other planets or moons in our Solar System. It has been hypothesized that one environment which might foster such life is associated with sub-seafloor hydrothermal vent structures. The goal of the MSMS project is to develop an instrument capable of testing this hypothesis. The MSMS instrument is an evolution of a sea floor monitoring system developed by Dr. Adam Schultz. Its design is the result of many generations of hardware and dive programs. Medusa provides the capability to measure and sample effluent and influent sea floor hydraulic flows associated with hydrothermal vent structures, active sea mounds, and sea floor bore holes. Through this proposal we are developing the next generation Medusa system and initiating the integration of several select chemical and biological sensors into the Medusa backbone. These sensors are an in situ flow-through spectral chemistry system, a cavity ringdown 12C/13C system, and an intrinsic fluorescence instrument. der way. This instrument can be used to target and discriminate between biological samples for automated sample collection
The Penn State Safety Floor: Part I--Design parameters associated with walking deflections.
Casalena, J A; Ovaert, T C; Cavanagh, P R; Streit, D A
1998-08-01
A new flooring system has been developed to reduce peak impact forces to the hips when humans fall. The new safety floor is designed to remain relatively rigid under normal walking conditions, but to deform elastically when impacted during a fall. Design objectives included minimizing peak force experienced by the femur during a fall-induced impact, while maintaining a maximum of 2 mm of floor deflection during walking. Finite Element Models (FEMs) were developed to capture the complex dynamics of impact response between two deformable bodies. Validation of the finite element models included analytical calculations of theoretical buckling column response, experimental quasi-static loading of full-scale flooring prototypes, and flooring response during walking trials. Finite Element Method results compared well with theoretical and experimental data. Both finite element and experimental data suggest that the proposed safety floor can effectively meet the design goal of 2 mm maximum deflection during walking, while effectively reducing impact forces during a fall.
Fujita, S; Obara, T; Tanaka, I; Yamauchi, C
1981-01-01
The relation of the rate of circulating air change to room temperature and relative humidity in animal quarters with a central air-conditioning system during heating and cooling seasons was investigated, with the results as follows: During the period of heating, the ambient temperature generally rose with a fall of relative humidity as the number of conditioned air changes per hour was increased. Vertical differences in temperature and humidity between levels of 0.5 and 1.5 m above the floor also diminished with increasing air change rate. This tendency was more conspicuous in small animals rooms with outer walls facing north and west. With increasing rate of air changes, the room temperature was prone to decline and the relative humidity to rise during the period of cooling. There were less vertical differences in temperature and humidity during this period. The velocity of air circulation within the animal quarters and its variations tended to increase progressively with increasing rate of ventilation, though the changes were modest.
Measure Guideline: Implementing a Plenum Truss for a Compact Air Distribution System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burdick, A.
2013-10-01
This Measure Guideline presents the steps to implement a compact duct system inside an attic bulkhead (plenum truss) of a one-story, slab-on-grade (SOG) home. In a compact duct design, ductwork runs are reduced in length to yield a smaller and more compact duct system. Less energy will be lost through ductwork if the ducts are contained within the thermal enclosure of the house. These measures are intended for the production builder working to meet the 2012 International Energy Conservation Code (IECC) requirements and keep the ductwork within the thermal enclosure of the house. This measure of bringing the heating, ventilationmore » and air conditioning (HVAC) equipment and ductwork within the thermal enclosure of the house is appropriate for the builder wishing to avoid cathedralizing the insulation in the attic space (i.e., locating it at the underside of the roof deck rather than along the attic floor) or adding dropped soffits.« less
Measure Guideline: Implementing a Plenum Truss for a Compact Air Distribution System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burdick, A.
2013-10-01
This Measure Guideline presents the steps to implement a compact duct system inside an attic bulkhead (plenum truss) of a one-story, slab-on-grade home. In a compact duct design, ductwork runs are reduced in length to yield a smaller and more compact duct system. Less energy will be lost through ductwork if the ducts are contained within the thermal enclosure of the house. These measures are intended for the production builder working to meet the 2012 International Energy Conservation Code (IECC) requirements and keep the ductwork within the thermal enclosure of the house. This measure of bringing the heating, ventilation andmore » air conditioning (HVAC) equipment and ductwork within the thermal enclosure of the house is appropriate for the builder wishing to avoid cathedralizing the insulation in the attic space (i.e., locating it at the underside of the roof deck rather than along the attic floor) or adding dropped soffits.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Charbonneau, Mark William
Processes of controlling submerged combustion melters, and systems for carrying out the methods. One process includes feeding vitrifiable material into a melter vessel, the melter vessel including a fluid-cooled refractory panel in its floor, ceiling, and/or sidewall, and heating the vitrifiable material with a burner directing combustion products into the melting zone under a level of the molten material in the zone. Burners impart turbulence to the molten material in the melting zone. The fluid-cooled refractory panel is cooled, forming a modified panel having a frozen or highly viscous material layer on a surface of the panel facing the moltenmore » material, and a sensor senses temperature of the modified panel using a protected thermocouple positioned in the modified panel shielded from direct contact with turbulent molten material. Processes include controlling the melter using the temperature of the modified panel. Other processes and systems are presented.« less
A marine dynamic penetrometer for the determination of sea floor geotechnical properties
NASA Astrophysics Data System (ADS)
Stephan, S.; Kaul, N. E.; Villinger, H. W.
2013-12-01
We present a seafloor lance penetration monitoring system: the Lance Insertion Retardation Meter (LIRmeter). The device can be used to infer geotechnical seafloor properties, such as bearing capacity by monitoring the deceleration of a free-fall penetrating lance. The deceleration record can be furthermore used to estimate mean grain size and mud content of the sea floor as well as total penetration depth. The LIRmeter is contained in a pressure vessel (440 x 110 mm) and equipped with accelerometers of different sensitivities to (i) determine sea floor resistance during penetration and (ii) to generate a depth axis. Typically, measurements are carried out in a pogo style fashion to allow a rapid measurement progress during field campaigns. The LIRmeter is intended to determine sea floor properties on the sole basis of deceleration measurements in order to achieve a mechanically and electronically robust system. Data is sampled at a resolution of 16 bit and at a rate of typically 500 Hz for each channel. The device can either be installed in any type of lance i.e. marine heat flow probes, gravity corers, piston corers or can be used in combination with a purpose built lance as a standalone instrument. It has a usable length of four meters, a total weight of 280 kg in air and can be operated up to full ocean depth (6000m). The bearing capacity of the sea floor is a critical factor for marine engineering projects such as burial of marine cables, pipeline laying and foundations. Knowledge of the mud content can provide constraints for the estimation of hydraulic conductivity. The identification of weak zones along a slope can moreover provide vital information for risk assessment studies. Traditionally, frame based, quasi static Cone Penetration Tests (CPT) or sampling methods like gravity coring are used to conduct these types of investigation. In comparison to established but time consuming and rather costly methods, the LIRmeter is intended (i) for near surface investigations and/or (ii) to complement and connect conventional but isolated CPT measurements in a very efficient and rapid way. We show results from measurements in the North Sea, as well as results of laboratory experiments. During sea trials, the LIRmeter was equipped with an additional CPT sensor, which delivered data for cone (tip) resistance, sleeve friction and pore pressure, thus allowing a direct comparison between results of the acceleration measurements and results from conventional CPT sensors. The laboratory measurements were also carried out using both acceleration and tip resistance sensors. Resulting values show a very good agreement between tip resistance calculated from deceleration data and tip resistance from direct laboratory and field measurements. The influence of sediment type (mainly mud content) will be discussed within the context of laboratory measurements.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-14
... new Options Floor Broker Management System. II. Self-Regulatory Organization's Statement of the... SECURITIES AND EXCHANGE COMMISSION [Release No. 34-70141; File No. SR-Phlx-2013-83] Self... Change To Delay the Implementation of the Options Floor Broker Management System Until the End of...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-26
... Floor Broker Management System. II. Self-Regulatory Organization's Statement of the Purpose of, and... SECURITIES AND EXCHANGE COMMISSION [Release No. 34-69811; File No. SR-Phlx-2013-67] Self... Change To Delay the Implementation of its New Options Floor Broker Management System June 20, 2013...
24. View of lobby area on first floor transmitter building ...
24. View of lobby area on first floor transmitter building no. 102 looking into controlled access corridor and door system - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK
16. Photocopy of drawing, floor system plan, Bridge No. 79B, ...
16. Photocopy of drawing, floor system plan, Bridge No. 79B, Main & Washington Sts., So. Norwalk, Ct., N. Y. Division, N.Y., N.H. and H.R.R., dated April 23, 1895. Original on file with Metro North Commuter Railroad. - South Norwalk Railroad Bridge, South Main & Washington Streets, Norwalk, Fairfield County, CT
Dynamic compensation in the central Pacific Ocean
NASA Technical Reports Server (NTRS)
Hinojosa, Juan Homero; Marsh, Bruce D.
1988-01-01
The intermediate-wavelength geoid (lambda similar to 2000 km) and sea-floor topography fields in the central Pacific Ocean were studied in terms of static and dynamic compensation models. Topographic features on the sea-floor with lambda less than 1000 km were found to be compensated both regionally, by the elastic strength of the lithosphere, and locally, by displacing mantle material to reach isostatic adjustment. The larger-scale sea-floor topography and the corresponding geoid anomalies with lambda similar to 2000 km cannot be explained by either local or regional compensation. The topography and the resulting geoid anomaly at this wavelength were modeled by considering the dynamic effects arising from viscous stresses in a layer of fluid with a highly temperature-dependent viscosity for the cases of: (1) surface cooling, and (2) basal heating. In this model, the mechanical properties of the elastic part of the lithosphere were taken into account by considering an activation energy of about 520 kJ/mol in the Arrhenius law for the viscosity. Numerical predictions of the topography, total geoid anomaly, and admittance were obtained, and the results show that the thermal perturbation in the layer, which accounts for the mass deficit, must be located close to the surface to compensate the gravitational effect of the surface deformation. For the case of basal heating, the temperature dependence of viscosity results in a separation of the upper, quasi-rigid lid from the lower mobile fluid, hence inhibiting the development of a compensating thermal perturbation at shallow depths. The results clearly rule out small-scale, upper-mantle convection as the source of these anomalies. Instead, the geophysical observables can be well explained by a shallow, transient thermal perturbation.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-08
... LLC To Increase the Maximum Order Size Accepted by Floor Broker Systems From 25,000,000 Shares to 99... order size accepted by Floor broker systems from 25,000,000 shares to 99,000,000 shares. The text of the... systems shall accept a maximum order size of 99,000,000, an increase from the current 25,000,000 share...
VIEW FROM CHARGING FLOOR LOOKING EAST AT COAL HOPPER, AND ...
VIEW FROM CHARGING FLOOR LOOKING EAST AT COAL HOPPER, AND PHYSICAL REMAINS OF GAS PRODUCER SYSTEM. - Pittsburgh Steel Company, Monessen Works, Open Hearth Plant, Donner Avenue, Monessen, Westmoreland County, PA
A Study of the Energy-Saving Potential of Metal Roofs Incorporating Dynamic Insulation Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Biswas, Kaushik; Miller, William A; Kriner, Scott
2013-01-01
This article presents various metal roof configurations that were tested at Oak Ridge National Laboratory in Tennessee, U.S. between 2009 and 2013, and describes their potential for reducing the attic-generated space-conditioning loads. These roofs contained different combinations of phase-change material, rigid insulation, low emittance surface, and above-sheathing ventilation with standing-seam metal panels on top. These roofs were designed to be installed on existing roofs decks, or on top of asphalt shingles for retrofit construction. All the tested roofs showed the potential for substantial energy savings compared to an asphalt shingle roof, which was used as a control for comparison. Themore » roofs were constructed on a series of adjacent attics separated at the gables using thick foam insulation. The attics were built on top of a conditioned room. All attics were vented at the soffit and ridge. The test roofs and attics were instrumented with an array of thermocouples. Heat flux transducers were installed in the roof deck and attic floor (ceiling) to measure the heat flows through the roof and between the attic and conditioned space below. Temperature and heat flux data were collected during the heating, cooling and swing seasons over a three-year period. Data from previous years of testing have been published. Here, data from the latest roof configurations being tested in year three of the project are presented. All test roofs were highly effective in reducing the heat flows through the roof and ceiling, and in reducing the diurnal attic-temperature fluctuations.« less
Interactive computation of coverage regions for indoor wireless communication
NASA Astrophysics Data System (ADS)
Abbott, A. Lynn; Bhat, Nitin; Rappaport, Theodore S.
1995-12-01
This paper describes a system which assists in the strategic placement of rf base stations within buildings. Known as the site modeling tool (SMT), this system allows the user to display graphical floor plans and to select base station transceiver parameters, including location and orientation, interactively. The system then computes and highlights estimated coverage regions for each transceiver, enabling the user to assess the total coverage within the building. For single-floor operation, the user can choose between distance-dependent and partition- dependent path-loss models. Similar path-loss models are also available for the case of multiple floors. This paper describes the method used by the system to estimate coverage for both directional and omnidirectional antennas. The site modeling tool is intended to be simple to use by individuals who are not experts at wireless communication system design, and is expected to be very useful in the specification of indoor wireless systems.
ERIC Educational Resources Information Center
Stoever, Edward C., Jr.
Crustal Evolution Education Project (CEEP) modules were designed to: (1) provide students with the methods and results of continuing investigations into the composition, history, and processes of the earth's crust and the application of this knowledge to man's activities and (2) to be used by teachers with little or no previous background in the…
2011-06-30
CAPE CANAVERAL, Fla. -- In the RTG storage facility at NASA's Kennedy Space Center in Florida, the shipping cask enclosing the multi-mission radioisotope thermoelectric generator (MMRTG) for NASA's Mars Science Laboratory mission is lowered to the floor of the high bay in preparation for lifting the cask from around the MMRTG. The MMRTG will generate the power needed for the mission from the natural decay of plutonium-238, a non-weapons-grade form of the radioisotope. Heat given off by this natural decay will provide constant power through the day and night during all seasons. Waste heat from the MMRTG will be circulated throughout the rover system to keep instruments, computers, mechanical devices and communications systems within their operating temperature ranges. MSL's components include a compact car-sized rover, Curiosity, which has 10 science instruments designed to search for evidence on whether Mars has had environments favorable to microbial life, including chemical ingredients for life. The unique rover will use a laser to look inside rocks and release its gasses so that the rover’s spectrometer can analyze and send the data back to Earth. Launch of MSL aboard a United Launch Alliance Atlas V rocket is scheduled for Nov. 25 from Space Launch Complex 41 on Cape Canaveral Air Force Station in Florida. For more information, visit http://www.nasa.gov/msl. Photo credit: NASA/Frankie Martin
Design and Control of Hydronic Radiant Cooling Systems
NASA Astrophysics Data System (ADS)
Feng, Jingjuan
Improving energy efficiency in the Heating Ventilation and Air conditioning (HVAC) systems in buildings is critical to achieve the energy reduction in the building sector, which consumes 41% of all primary energy produced in the United States, and was responsible for nearly half of U.S. CO2 emissions. Based on a report by the New Building Institute (NBI), when HVAC systems are used, about half of the zero net energy (ZNE) buildings report using a radiant cooling/heating system, often in conjunction with ground source heat pumps. Radiant systems differ from air systems in the main heat transfer mechanism used to remove heat from a space, and in their control characteristics when responding to changes in control signals and room thermal conditions. This dissertation investigates three related design and control topics: cooling load calculations, cooling capacity estimation, and control for the heavyweight radiant systems. These three issues are fundamental to the development of accurate design/modeling tools, relevant performance testing methods, and ultimately the realization of the potential energy benefits of radiant systems. Cooling load calculations are a crucial step in designing any HVAC system. In the current standards, cooling load is defined and calculated independent of HVAC system type. In this dissertation, I present research evidence that sensible zone cooling loads for radiant systems are different from cooling loads for traditional air systems. Energy simulations, in EnergyPlus, and laboratory experiments were conducted to investigate the heat transfer dynamics in spaces conditioned by radiant and air systems. The results show that the magnitude of the cooling load difference between the two systems ranges from 7-85%, and radiant systems remove heat faster than air systems. For the experimental tested conditions, 75-82% of total heat gain was removed by radiant system during the period when the heater (simulating the heat gain) was on, while for air system, 61-63% were removed. From a heat transfer perspective, the differences are mainly because the chilled surfaces directly remove part of the radiant heat gains from a zone, thereby bypassing the time-delay effect caused by the interaction of radiant heat gain with non-active thermal mass in air systems. The major conclusions based on these findings are: 1) there are important limitations in the definition of cooling load for a mixing air system described in Chapter 18 of ASHRAE Handbook of Fundamentals when applied to radiant systems; 2) due to the obvious mismatch between how radiant heat transfer is handled in traditional cooling load calculation methods compared to its central role in radiant cooling systems, this dissertation provides improvements for the current cooling load calculation method based on the Heat Balance procedure. The Radiant Time Series method is not appropriate for radiant system applications. The findings also directly apply to the selection of space heat transfer modeling algorithms that are part of all energy modeling software. Cooling capacity estimation is another critical step in a design project. The above mentioned findings and a review of the existing methods indicates that current radiant system cooling capacity estimation methods fail to take into account incident shortwave radiation generated by solar and lighting in the calculation process. This causes a significant underestimation (up to 150% for some instances) of floor cooling capacity when solar load is dominant. Building performance simulations were conducted to verify this hypothesis and quantify the impacts of solar for different design scenarios. A new simplified method was proposed to improve the predictability of the method described in ISO 11855 when solar radiation is present. The dissertation also compares the energy and comfort benefits of the model-based predictive control (MPC) method with a fine-tuned heuristic control method when applied to a heavyweight embedded surface system. A first order dynamic model of a radiant slab system was developed for implementation in model predictive controllers. A calibrated EnergyPlus model of a typical office building in California was used as a testbed for the comparison. The results indicated that MPC is able to reduce the cooling tower energy consumption by 55% and pumping power consumption by 26%, while maintaining equivalent or even better thermal comfort conditions. In summary, the dissertation work has: (1) provided clear evidence that the fundamental heat transfer mechanisms differ between radiant and air systems. These findings have important implications for the development of accurate and reliable design and energy simulation tools; (2) developed practical design methods and guidance to aid practicing engineers who are designing radiant systems; and (3) outlined future research and design tools need to advance the state-of-knowledge and design and operating guidelines for radiant systems.
Individual variation in prelaying behaviour and the incidence of floor eggs.
Cooper, J J; Appleby, M C
1996-05-01
1. Floor eggs are a problem in non-cage systems for laying hens, as they require secondary egg collecting. Failure to lay in a well-defined nest site may also be a welfare problem for the hens, but only if their nesting motivation has been thwarted. We investigated the relationships between a hen's prelaying behaviour and its tendency to lay on the floor by recording the behaviour of 20 hens housed individually in wire cages with single littered nest boxes. 3. Most floor eggs (80%) were laid by the same 6 hens. These 6 "floor-layers" performed more nest seeking behaviour, less nest-building behaviour and less sitting prior to oviposition than the 14 hens that consistently laid in nest boxes. 4. The incidence of floor eggs declined with age. Both nest and floor laying hens performed less nest seeking behaviour with age. Floor layers, however, increased their performance of nesting behaviour, whilst nest layers performed less nesting behaviour with age. 5. Floor laying hens behaved as if they found the nest box less attractive than nest-laying hens; perhaps because they had lower nesting motivation, or perhaps because their nesting motivation was as high, but they less readily perceived the nest box as an appropriate nest site.
Description and modelling of the solar-hydrogen-biogas-fuel cell system in GlashusEtt
NASA Astrophysics Data System (ADS)
Hedström, L.; Wallmark, C.; Alvfors, P.; Rissanen, M.; Stridh, B.; Ekman, J.
The need to reduce pollutant emissions and utilise the world's available energy resources more efficiently has led to increased attention towards e.g. fuel cells, but also to other alternative energy solutions. In order to further understand and evaluate the prerequisites for sustainable and energy-saving systems, ABB and Fortum have equipped an environmental information centre, located in Hammarby Sjöstad, Stockholm, Sweden, with an alternative energy system. The system is being used to demonstrate and evaluate how a system based on fuel cells and solar cells can function as a complement to existing electricity and heat production. The stationary energy system is situated on the top level of a three-floor glass building and is open to the public. The alternative energy system consists of a fuel cell system, a photovoltaic (PV) cell array, an electrolyser, hydrogen storage tanks, a biogas burner, dc/ac inverters, heat exchangers and an accumulator tank. The fuel cell system includes a reformer and a polymer electrolyte fuel cell (PEFC) with a maximum rated electrical output of 4 kW el and a maximum thermal output of 6.5 kW th. The fuel cell stack can be operated with reformed biogas, or directly using hydrogen produced by the electrolyser. The cell stack in the electrolyser consists of proton exchange membrane (PEM) cells. To evaluate different automatic control strategies for the system, a simplified dynamic model has been developed in MATLAB Simulink. The model based on measurement data taken from the actual system. The evaluation is based on demand curves, investment costs, electricity prices and irradiation. Evaluation criteria included in the model are electrical and total efficiencies as well as economic parameters.
14. Interior view of the first floor, facing southwest, and ...
14. Interior view of the first floor, facing southwest, and showing elements of the cold storage refrigeration system attached to the ceiling. - Armour & Company Building, 100 Harris Avenue, Providence, Providence County, RI
French, David; Nadji, Nabil; Liu, Shawn X; Larjava, Hannu
2015-06-01
A novel osteotome trifactorial classification system is proposed for transcrestal osteotome-mediated sinus floor elevation (OSFE) sites that includes residual bone height (RBH), sinus floor anatomy (contour), and multiple versus single sites OSFE (tenting). An analysis of RBH, contour, and tenting was retrospectively applied to a cohort of 926 implants placed using OSFE without added bone graft and followed up to 10 years. RBH was divided into three groups: high (RBH > 6 mm), mid (RBH = 4.1 to 6 mm), and low (RBH = 2 to 4 mm). The sinus "contour" was divided into four groups: flat, concave, angle, and septa. For "tenting", single versus multiple adjacent OSFE sites were compared. The prevalence of flat sinus floors increased as RBH decreased. RBH was a significant predictor of failure with rates as follows: low- RBH = 5.1%, mid-RBH = 1.5%, and high-RBH = 0.4%. Flat sinus floors and single sites as compared to multiple sites had higher observed failure rates but neither achieved statistical significance; however, the power of the study was limited by low numbers of failures. The osteotome trifactorial classification system as proposed can assist planning OSFE cases and may allow better comparison of future OSFE studies.
Assessment of in-place wood floor systems
Michael O. Hunt; Robert J. Ross; Xiping Wang; Lawrence Andrew Soltis; R. R. Leavitt; Zhiyong Cai
2007-01-01
Structural assessment of in-place wood floors is currently limited to inspection of individual members. This is costly and laborious. Consequently, the continued use or adaptive reuse of old/historic buildings is often in jeopardy because of the lack of an efficient and economical assessment method. A systems approach of assessment is the subject of this research....
Could Zinc Whiskers Be Impacting Your Electronic Systems? Raise Your Awareness. Revision D
NASA Technical Reports Server (NTRS)
Sampson, Michael; Brusse, Jay
2003-01-01
During the past several decades electrical short circuits induced by "Zinc Whiskers" have been cited as the root cause of failure for various electronic systems (e.g., apnea monitors, telecom switches). These tiny filaments of zinc that may grow from some zinc-coated items (especially those coated by electroplating processes) have the potential to induce electrical shorts in exposed circuitry. Through this article, the authors describe a particular failure scenario attributed to zinc whiskers that has affected many facilities (including some NASA facilities) that utilized zinc-coated raised "access" floor tiles and support structures. Zinc whiskers that may be growing beneath your raised floor have the potential to wreak havoc on electronic systems operating above the floor.
NASA Astrophysics Data System (ADS)
Fontaine, F.; Peltier, A.; Kowalski, P.; Di Muro, A.; Villeneuve, N.; Ferrazzini, V.; Staudacher, T.
2017-12-01
Piton de la Fournaise, located on La Réunion Island in the South East Indian Ocean, is one of the most active basaltic volcanoes (hotspot) of the world with a mean eruption frequency <6 months over the last 20 years. The central dome of the shield is thought to host an active hydrothermal system evidenced by self-potential techniques early in the 90's and mining heat from a magmatic source located about 2-2.5 km below the summit. Surface manifestations of this activity such as fumeroles or hot grounds have however never been observed before 2007 when deep magma withdrawal from the magmatic horizon during the "eruption of the century" (>100×106 m3) on the island, led to the formation of a 400-m-deep, 1000-m-large, funnel-shaped summit caldera. Since then, the floor and inner flanks of this summit depression hosting hot grounds and active fumaroles, are monitored using an infra-red camera device permanently installed on the caldera rim.This thermal dataset constitutes the first opportunity to understand the structure and dynamics of the hydrothermal system and its ability to relay deep-seated heat and mass perturbations. We present in this communication an overview of this thermal datasets focusing on ground/fumaroles temperature evolution during volcanic crisis and rest periods and analyzing correlations with the other permanently acquired data such as the temporal evolution of gas geochemistry (CO2, SO2, H2S), ground deformation and micro-seismic activity. We finally propose a conceptual model of fluid flow architecture within the edifice which paves the way for future quantitative models of hydrothermal heat and mass transfers.
29. SECOND FLOOR EAST SIDE APARTMENT EAST BEDROOM INTERIOR. ALUMINUMFRAME ...
29. SECOND FLOOR EAST SIDE APARTMENT EAST BEDROOM INTERIOR. ALUMINUM-FRAME SLIDING-GLASS WINDOWS ARE REPLACEMENTS. VIEW TO NORTHEAST. - Lee Vining Creek Hydroelectric System, Triplex Cottage, Lee Vining Creek, Lee Vining, Mono County, CA
97. VIEW NORTHWEST OF 4TH FLOOR OF BUILDING 112; NOTE ...
97. VIEW NORTHWEST OF 4TH FLOOR OF BUILDING 112; NOTE REMNANTS OF BEARING SUPPORTS FOR OVERHEAD BELT AND PULLEY POWER TRANSMISSION SYSTEM - Scovill Brass Works, 59 Mill Street, Waterbury, New Haven County, CT
Network support for turn-taking in multimedia collaboration
NASA Astrophysics Data System (ADS)
Dommel, Hans-Peter; Garcia-Luna-Aceves, Jose J.
1997-01-01
The effectiveness of collaborative multimedia systems depends on the regulation of access to their shared resources, such as continuous media or instruments used concurrently by multiple parties. Existing applications use only simple protocols to mediate such resource contention. Their cooperative rules follow a strict agenda and are largely application-specific. The inherent problem of floor control lacks a systematic methodology. This paper presents a general model on floor control for correct, scalable, fine-grained and fair resource sharing that integrates user interaction with network conditions, and adaptation to various media types. The motion of turn-taking known from psycholinguistics in studies on discourse structure is adapted for this framework. Viewed as a computational analogy to speech communication, online collaboration revolves around dynamically allocated access permissions called floors. The control semantics of floors derives from concurrently control methodology. An explicit specification and verification of a novel distributed Floor Control Protocol are presented. Hosts assume sharing roles that allow for efficient dissemination of control information, agreeing on a floor holder which is granted mutually exclusive access to a resource. Performance analytic aspects of floor control protocols are also briefly discussed.
General engineering specifications for 6000 tpd SRC-I Demonstration Plant
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
This volume contains specifications for architectural features of buildings for the SRC-1 Demonstration Plant: skylights, ventilators, sealants, doors, mirrors, furring and lathing, gypsum plaster, lightweight plaster, wallboard, ceramic tile, acoustic ceiling systems, resilient flooring, carpeting, brick flooring, architectural painting, vinyl wall covering, chalkboards, tackboards, toilets, access flooring, lockers, partitions, washroom accessories, unit kitchens, dock levels, seals, shelters, custom casework, auditorium seats, drapery tacks, prefabricated buildings, stairs, elevators, shelves, etc. (LTN).
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
In many two-story homes, there are attic spaces above the first-floor of the home that border portions of the second-story conditioned space. These spaces have breaches of the air and thermal boundaries, creating a phenomenon known as wind washing. This can cause attic air above the first-floor space to be driven into the cavity between the first and second floors by wind, thermal buoyancy forces, or mechanical driving forces as well as circulation of hot attic air against the wallboard because of gaps between insulation batts installed on knee walls and the gypsum wallboard. In this project, the U.S. Departmentmore » of Energy team Building America Partnership for Improved Residential Construction (BA-PIRC) investigated wind washing in 56 homes. The goals were to identify the failure mechanisms that lead to wind washing, characterize the pathways for air and heat to enter the house, and evaluate the seasonal energy savings and peak demand reduction that can result from repairing these wind washing problems. Based on this research, the team developed recommendations for cost-effective retrofit solutions and information that can help avoid these problems in new construction.« less
Major off-axis hydrothermal activity on the northern Gorda Ridge
Rona, Peter A.; Denlinger, Roger P.; Fisk, M. R.; Howard, K. J.; Taghon, G. L.; Klitgord, Kim D.; McClain, James S.; McMurray, G. R.; Wiltshire, J. C.
1990-01-01
The first hydrothermal field on the northern Gorda Ridge, the Sea Cliff hydrothermal field, was discovered and geologic controls of hydrothermal activity in the rift valley were investigated on a dive series using the DSV Sea Cliff. The Sea Cliff hydrothermal field was discovered where predicted at the intersection of axis-oblique and axis-parallel faults at the south end of a linear ridge at mid-depth (2700 m) on the east wall. Preliminary mapping and sampling of the field reveal: a setting nested on nearly sediment-free fault blocks 300 m above the rift valley floor 2.6 km from the axis; a spectrum of venting types from seeps to black smokers; high conductive heat flow estimated to be equivalent to the convective flux of multiple black smokers through areas of the sea floor sealed by a caprock of elastic breccia primarily derived from basalt with siliceous cement and barite pore fillings; and a vent biota with Juan de Fuca Ridge affinites. These findings demonstrate the importance of off-axis hydrothermal activity and the role of the intersection of tectonic lineations in controlling hydrothermal sites at sea-floor spreading centers.
Comparison among NH3 and GHGs emissive patterns from different housing solutions of dairy farms
NASA Astrophysics Data System (ADS)
Baldini, Cecilia; Borgonovo, Federica; Gardoni, Davide; Guarino, Marcella
2016-09-01
Agriculture and livestock farming are known to be activities emitting relevant quantities of atmospheric pollutants. In particular, in intensive animal farming, buildings can be identified as a relevant source of ammonia and greenhouse gases. This study aimed at: i) determining the emission factors of NH3, N2O, CH4, and CO2 from different dairy farms in Italy, and ii) assessing the effects of the different floor types and manure-handling systems used, in order to minimize the impact of this important productive sector. A measurement campaign was carried out for 27 months in four naturally ventilated dairy cattle buildings with different floor types, layouts and manure management systems, representative of the most common technologies in the north of Italy. Gas emissions were measured with the ;static chamber method;: a chamber was placed above the floor farm and an infrared photoacoustic detector (IPD) was used to monitor gas accumulation over time. In the feeding alleys, emissions of NH3 were higher from solid floors than from flushing systems and perforated floors. N2O emissions were significantly different among farms but the absolute values were relatively low. CH4 and CO2 emissions were higher from perforated floors than from other types of housing solution. Regarding the cubicles, the emissions of NH3 were approximately equal from the two housing solution studied. Contrariwise, N2O, CH4 and CO2 emissions were different between the cubicles with rubber mat and those with straw where the highest values were found.
Anhydrite precipitation in seafloor hydrothermal systems
NASA Astrophysics Data System (ADS)
Theissen-Krah, Sonja; Rüpke, Lars H.
2016-04-01
The composition and metal concentration of hydrothermal fluids venting at the seafloor is strongly temperature-dependent and fluids above 300°C are required to transport metals to the seafloor (Hannington et al. 2010). Ore-forming hydrothermal systems and high temperature vents in general are often associated with faults and fracture zones, i.e. zones of enhanced permeabilities that act as channels for the uprising hydrothermal fluid (Heinrich & Candela, 2014). Previous numerical models (Jupp and Schultz, 2000; Andersen et al. 2015) however have shown that high permeabilities tend to decrease fluid flow temperatures due to mixing with cold seawater and the resulting high fluid fluxes that lead to short residence times of the fluid near the heat source. A possible mechanism to reduce the permeability and thereby to focus high temperature fluid flow are mineral precipitation reactions that clog the pore space. Anhydrite for example precipitates from seawater if it is heated to temperatures above ~150°C or due to mixing of seawater with hydrothermal fluids that usually have high Calcium concentrations. We have implemented anhydrite reactions (precipitation and dissolution) in our finite element numerical models of hydrothermal circulation. The initial results show that the precipitation of anhydrite efficiently alters the permeability field, which affects the hydrothermal flow field as well as the resulting vent temperatures. C. Andersen et al. (2015), Fault geometry and permeability contrast control vent temperatures at the Logatchev 1 hydrothermal field, Mid-Atlantic Ridge, Geology, 43(1), 51-54. M. D. Hannington et al. (2010), Modern Sea-Floor Massive Sulfides and Base Metal Resources: Toward an Estimate of Global Sea-Floor Massive Sulfide Potential, in The Challenge of Finding New Mineral Resources: Global Metallogeny, Innovative Exploration, and New Discoveries, edited by R. J. Goldfarb, E. E. Marsh and T. Monecke, pp. 317-338, Society of Economic Geologists. Heinrich, C. A., and P. A. Candela (2014), 13.1 - Fluids and Ore Formation in the Earth's Crust, in Treatise on Geochemistry (Second Edition), edited by H. D. Holland and K. K. Turekian, pp. 1-28, Elsevier, Oxford. Jupp, T., and A. Schultz (2000), A thermodynamic explanation for black smoker temperatures, Nature, 403(6772), 880-883.
Ryen, Linda; Svensson, Mikael
2016-06-01
Fall-related injuries among the elderly, specifically hip fractures, cause significant morbidity and mortality as well as imposing a substantial financial cost on the health care system. Impact-absorbing flooring has been advocated as an effective method for preventing hip fractures resulting from falls. This study identifies the cost-effectiveness of impact-absorbing flooring compared to standard flooring in residential care facilities for the elderly in a Swedish setting. An incremental cost-effectiveness analysis was performed comparing impact-absorbing flooring to standard flooring using a Markov decision model. A societal perspective was adopted and incremental costs were compared to incremental gains in quality-adjusted life years (QALYs). Data on costs, probability transitions and health-related quality of life measures were retrieved from the published literature and from Swedish register data. Probabilistic sensitivity analysis was performed through a Monte Carlo simulation. The base-case analysis indicates that the impact-absorbing flooring reduces costs and increases QALYs. When allowing for uncertainty we find that 60% of the simulations indicate that impact-absorbing flooring is cost-saving compared to standard flooring and an additional 20% that it has a cost per QALY below a commonly used threshold value : Using a modelling approach, we find that impact-absorbing flooring is a dominant strategy at the societal level considering that it can save resources and improve health in a vulnerable population. © The Author 2015. Published by Oxford University Press on behalf of the European Public Health Association. All rights reserved.
Robert M. Loomis; William A. Main
1980-01-01
Relations between certain slash and forest floor moisture contents and the applicable estimated time lag fuel moistures of the National Fire Danger Rating System were investigated for 1-year-old jack pine fuel types in northeastern Minnesota and central Lower Michigan. Only approximate estimates of actual fuel moisture are possible fore the relations determined, thus...
Creating Library Interiors: Planning and Design Considerations.
ERIC Educational Resources Information Center
Jones, Plummer Alston, Jr.; Barton, Phillip K.
1997-01-01
Examines design considerations for public library interiors: access; acoustical treatment; assignable and nonassignable space; building interiors: ceilings, clocks, color, control, drinking fountains; exhibit space: slotwall display, floor coverings, floor loading, furniture, lighting, mechanical systems, public address, copying machines,…
INTERIOR, FIRST FLOOR, A view looking toward the north wall ...
INTERIOR, FIRST FLOOR, A view looking toward the north wall of Room 164, showing the intricate mechanical systems which supported the operation - Department of Energy, Mound Facility, B Building, One Mound Road, Miamisburg, Montgomery County, OH
Experimental Building Information Models
2011-09-01
ER D C/ CE RL C R- 11 -2 Experimental Building Information Models Co ns tr uc tio n En gi ne er in g R es ea rc h La bo ra to ry...Foundations, floor slabs , framing, stairs and elevators. • Mechanical: Heating, ventilating, and air conditioning equipment, thermostats, ducts, and...Single Flush .rvt Other standards and considerations – In a traditional cad environment, drawing layers are used to organize drawing objects and
10. Looking northwest at the "community" area at the center ...
10. Looking northwest at the "community" area at the center of the store, and beyond at the main sales counters along the west wall; metal sheathing to protect the wood floor from the former heating stove can be seen in the foreground, and a wooden drawer unit for seeds is beyond the chairs - Horsepasture Store, U.S. Route 58 & State Route 687, Horse Pasture, Henry County, VA
Patrick J. McHale; Myron J. Mitchell; Dudley J. Raynal; Francis P. Bowles
1996-01-01
To investigate the effects of elevated soil temperatures on a forest ecosystem, heating cables were buried at a depth of 5 cm within the forest floor of a northern hardwood forest at the Huntington Wildlife Forest (Adirondack Mountains, New York). Temperature was elevated 2.5, 5.0 and 7.5?C above ambient, during May - September in both 1993 and 1994. Various aspects of...
NASA Astrophysics Data System (ADS)
Dixon, T. H.; Xie, S.; Malservisi, R.; Lembke, C.; Iannaccone, G.; Law, J.; Rodgers, M.; Russell, R.; Voss, N. K.
2017-12-01
A GPS-buoy system has been built and is currently undergoing test to measure precise 3D sea floor motion in the shallow (less than 200 m) continental shelf environment. Offshore deformation is undersampled in most subduction zones. In Cascadia, the shallow shelf environment constitutes roughly 20%-25% of the offshore area between the coastline and the trench. In the system being tested, the GPS receiver at the top of the buoy is connected to the sea floor through a rigid structure supported by a float. A similar design has been used by INGV (Italy) to measure vertical deformation on the sea floor near the Campi Flegrei caldera. Synthetic analysis shows that by adding a 3-axis digital compass to measure heading and tilt, along with kinematic GPS measurements, position of the anchor can be recovered to an accuracy of several centimeters or better, depending on water depth and GPS baseline length. Synthetic resolution tests show that our ability to detect shallow slow slip events on subduction plate boundaries can be greatly improved by adding offshore GPS-buoy sites.
A new idea: The possibilities of offshore geothermal system in Indonesia marine volcanoes
NASA Astrophysics Data System (ADS)
Rahat Prabowo, Teguh; Fauziyyah, Fithriyani; Suryantini; Bronto, Sutikno
2017-12-01
High temperature geothermal systems in Indonesia are commonly associated with volcanic systems. It is believed that volcanoes are acting as the heat source for a geothermal system. Right now, most of the operating geothermal fields in the world are assosiating with volcanic settings which known as the conventional geothermal system. Volcanoes are created in active tectonic zone such as collision zone and MOR (mid oceanic ridge). The later is the one which formed the marine volcanoes on the sea floor. The advances of today’s technology in geothermal energy has created many ideas regarding a new kind of geothermal system, including the ideas of developing the utilization of marine volcanoes. These marine volcanoes are predicted to be hotter than the land system due to the shorter distance to the magma chamber. Seamounts like NEC, Banua Wuhu, and Kawio Barat in Indonesia Sea are good spots to be studied. Methods such as remote sensing using NOAA images, sonar, and MAPR are commonly used, eventhough these would be more accurate with more detailed techniques. This has become the challenge for all geothermal scientists to overcome for a better study result.
Riber, A B; Hinrichsen, L K
2016-07-01
Feather eating has been associated with feather pecking, which continues to pose economic and welfare problems in egg production. Knowledge on feather eating is limited and studies of feather eating in commercial flocks of laying hens have not been performed previously. Therefore, the main objective was to investigate feather eating and its association with plumage damage and floor feather characteristics in commercial flocks of layers in barn and organic production systems. The study was performed in 13 flocks of barn layers and 17 flocks of organic layers. Each flock was visited at around 32 and 62 weeks of age. During both visits, the plumage condition was assessed and the density of floor feathers recorded. In week 62, droppings and floor feathers were collected. Droppings were examined for presence of feather content, whereas length, downiness and pecking damage were recorded for each floor feather. In week 62, a higher prevalence of hens with poor plumage condition was found in barn (22.2%) compared with organic production systems (7.4%; P<0.001), but the prevalence of droppings with feather content did not differ between the two production systems (8.5% in barn v. 4.3% in organic; P=0.99). Our hypothesis about a positive correlation between feather eating and plumage damage was not supported as no correlation was found between the prevalence of poor plumage condition and the prevalence of droppings with feather content. However, the prevalence of pecking damaged floor feathers was positively correlated both with prevalence of droppings with feather content (P<0.05) and poor plumage condition (P<0.01), indicating a possible association between feather eating and feather pecking. In conclusion, it was confirmed that feather eating occurs on-farm, but feather eating was only found to be positively correlated to the number of floor feathers with pecking damage and not as expected to the prevalence of plumage damage. More research is needed into the sources from where feathers are selected for ingestion, that is, whether they are picked from the floor litter, plucked directly from other hens or dislodged during preening of own feathers.
Wang, W; Wideman, R F; Chapman, M E; Bersi, T K; Erf, G F
2003-12-01
Commercial broilers are constantly exposed to airborne microorganisms and endotoxin (lipopolysaccharide, LPS). It has been shown that microbial contamination of the air was higher in broiler houses using floor litter than in broiler houses using netting-type floors. The current study evaluated the effect of housing conditions on blood leukocyte profiles and tested the hypothesis that, when compared to broilers reared in clean stainless steel cages (Cage group), broilers raised on floor litter (Floor group) should experience a higher environmental challenge and have a desensitized immune system that may exhibit better tolerance/resistance to subsequent intravenous LPS challenge. Hematological parameters were evaluated prior to and following i.v. administration of 1 mg/kg BW Salmonella typhimurium LPS (dissolved at 1 mg/0.25 mL in PBS) or i.v. injection of 0.25 mL/kg BW PBS alone. The results showed that prior to LPS/PBS injection, broilers in the cage group had higher heterophil and monocyte concentrations, a higher B cell percentage within the lymphocyte population, and a higher heterophil to lymphocyte (H:L) ratio in the blood. The i.v. LPS injection resulted in 25% mortality in the cage group and 42% mortality in the floor group within 8 h post-injection. LPS reduced the concentrations of total white blood cells (WBC) and all differential WBC except eosinophils and increased thrombocyte concentrations within 1 h post-injection in both groups. All of these values returned to their respective pre-injection levels within 48 h post-injection in the surviving birds. The two groups exhibited similar overall hematological changes after LPS injection except that the cage group showed a higher H:L ratio at 8 h post-injection and a lower B-cell percentage within the lymphocyte population at 48 h post-injection when compared with the floor group. We concluded that the immune systems of broilers reared on floor litter were desensitized and exhibited less pronounced leukocyte responses to i.v. LPS when compared with those of broilers reared in clean stainless steel cages. However, such desensitization of the immune system did not help broilers survive subsequent i.v. LPS challenge.
2011-07-12
CAPE CANAVERAL, Fla. -- In the airlock of the Payload Hazardous Servicing Facility (PHSF) at NASA's Kennedy Space Center in Florida, the protective mesh container enclosing the multi-mission radioisotope thermoelectric generator (MMRTG) for NASA's Mars Science Laboratory (MSL) mission is lowered to the floor of the airlock beside the MMRTG. The container, known as the "gorilla cage," protects the MMRTG during transport and allows any excess heat generated to dissipate into the air. Next, the airlock will be transitioned into a clean room by purging the air of any particles. In the PHSF, the MMRTG temporarily will be installed on the MSL rover, Curiosity, for a fit check but will be installed on the rover for launch at the pad. The MMRTG will generate the power needed for the mission from the natural decay of plutonium-238, a non-weapons-grade form of the radioisotope. Heat given off by this natural decay will provide constant power through the day and night during all seasons. Curiosity, MSL's car-sized rover, has 10 science instruments designed to search for signs of life, including methane, and help determine if the gas is from a biological or geological source. Waste heat from the MMRTG will be circulated throughout the rover system to keep instruments, computers, mechanical devices and communications systems within their operating temperature ranges. Launch of MSL aboard a United Launch Alliance Atlas V rocket is planned for Nov. 25 from Space Launch Complex 41 on Cape Canaveral Air Force Station. For more information, visit http://www.nasa.gov/msl. Photo credit: NASA/Cory Huston
Inohaya, Keiji; Takano, Yoshiro; Kudo, Akira
2010-06-01
The floor plate is a key organizer that controls the specification of neurons in the central nervous system. Here, we show a new role of the floor plate: segmental pattern formation of the vertebral column. Analysis of a spontaneous medaka mutant, fused centrum (fsc), which exhibits fused centra and the absence of the intervertebral ligaments, revealed that fsc encodes wnt4b, which was expressed exclusively in the floor plate. In fsc mutants, we found that wnt4b expression was completely lost in the floor plate and that abnormal conversion of the intervertebral ligament cells into osteoblasts appeared to cause a defect of the intervertebral ligaments. The establishment of the transgenic rescue lines and mosaic analyses allowed the conclusion to be drawn that production of wnt4b by floor plate cells is essential for the segmental patterning of the vertebral column. Our findings provide a novel perspective on the mechanism of vertebrate development.
Performance Support on the Shop Floor.
ERIC Educational Resources Information Center
Kasvi, Jyrki J. J.; Vartiainen, Matti
2000-01-01
Discussion of performance support on the shop floor highlights four support systems for assembly lines that incorporate personal computer workstations in local area networks and use multimedia documents. Considers new customer-focused production paradigms; organizational learning; knowledge development; and electronic performance support systems…
22. FIRST FLOOR APARTMENT SOUTH BEDROOM INTERIOR SHOWING PAIRED 6LIGHT ...
22. FIRST FLOOR APARTMENT SOUTH BEDROOM INTERIOR SHOWING PAIRED 6-LIGHT OVER 6-LIGHT DOUBLE-HUNG, WOOD-FRAMED WINDOWS. VIEW TO SOUTH. - Lee Vining Creek Hydroelectric System, Triplex Cottage, Lee Vining Creek, Lee Vining, Mono County, CA
Post-speleogenetic biogenic modification of Gomantong Caves, Sabah, Borneo
NASA Astrophysics Data System (ADS)
Lundberg, Joyce; McFarlane, Donald A.
2012-07-01
The Gomantong cave system of eastern Sabah, Malaysia, is well-known as an important site for harvesting edible bird-nests and, more recently, as a tourist attraction. Although the biology of the Gomantong system has been repeatedly studied, very little attention has been given to the geomorphology. Here, we report on the impact of geobiological modification in the development of the modern aspect of the cave, an important but little recognized feature of tropical caves. Basic modeling of the metabolic outputs from bats and birds (CO2, H2O, heat) reveals that post-speleogenetic biogenic corrosion can erode bedrock by between ~ 3.0 mm/ka (1 m/~300 ka) and ~ 4.6 mm/ka (1 m/~200 ka). Modeling at high densities of bats yields rates of corrosion of ~ 34 mm/ka (or 1 m/~30 ka). Sub-aerial corrosion creates a previously undescribed speleological feature, the apse-flute, which is semicircular in cross-section and ~ 80 cm wide. It is vertical regardless of rock properties, developing in parallel but apparently completely independently, and often unbroken from roof to floor. They end at a blind hemi-spherical top with no extraneous water source. Half-dome ceiling conch pockets are remnants of previous apse-fluting. Sub-cutaneous corrosion creates the floor-level guano notch formed by organic acid dissolution of bedrock in contact with guano. Speleogenetic assessment suggests that as much as 70-95% of the total volume of the modern cave may have been opened by direct subaerial biogenic dissolution and biogenically-induced collapse, and by sub-cutaneous removal of limestone, over a timescale of 1-2 Ma.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kendall, P.W.
The El Toro Library is a one-story facility that contains 10,000 square feet of floor area. The solar energy system was designed to provide 97% of the space heating load and 60% of the space cooling load. The solar energy system incorporates 82 panels with a gross area of 1427 square feet of evacuated tubular glass collectors (TC-100) manufactured by General Electric. The storage tank is a 1500-gallon insulated steel tank which is located outside, above ground level. The space heating subsystem uses solar energy from storage and/or thermal energy from the natural-gas-fired boiler. The space cooling subsystem uses anmore » absorption chiller to provide chilled water to the air-handling unit. As compared to the previous year, performance over the nine-month monitoring period was improved, based on overall solar contribution to the load. When compared to design values, the overall performance was poor. Overall solar fraction was an estimated 22% of the 220 million Btu system load. A total of 122 million Btu of solar energy was used by the space conditioning system. Auxiliary fossil fuel consumption was 608 million Btu, or 595,800 cubic feet of natural gas. Auxiliary thermal energy was a measured 68% of the auxiliary fossil fuel consumed. The solar savings ratio, a measure of the solar contribution to the load discounted by solar operating energy, averaged 19% during the analysis period. The previous year, the solar savings ratio was 16%.« less
Hakin, K N; Ham, J; Lightman, S L
1991-01-01
Most cases of non-necrotising scleritis can be successfully treated with non-steroidal anti-inflammatory drugs. If these are ineffective, then high-dose systemic corticosteroids, with all their attendant side-effects, are usually required. We have used orbital floor injections of depot steroid in the management of nine patients with non-necrotising scleritis in an attempt to avoid the use of systemic steroids, or to allow the dose of steroids to be reduced while maintaining disease control. A temporary reduction in inflammation was achieved in all cases, which allowed the use of systemic steroids to be avoided altogether in two patients and delayed in the others. Non-steroidal anti-inflammatory drugs and systemic corticosteroids remain the mainstay of treatment for non-necrotising scleritis, but orbital floor injections may be a useful adjunct in certain cases. Images PMID:2043574
NASA Technical Reports Server (NTRS)
Froidevaux, C.; Schubert, G.; Yuen, D. A.
1976-01-01
Temperature, velocity, and viscosity profiles for coupled thermal and mechanical models of the upper mantle beneath continental shields and old ocean basins show that under the continents, both tectonic plates and the asthenosphere, are thicker than they are beneath the oceans. The minimum value of viscosity in the continental asthenosphere is about an order of magnitude larger than in the shear zone beneath oceans. The shear stress or drag underneath continental plates is also approximately an order of magnitude larger than the drag on oceanic plates. Effects of shear heating may account for flattening of ocean floor topography and heat flux in old ocean basins.
Carbon dioxide and methane emissions from the scale model of open dairy lots.
Ding, Luyu; Cao, Wei; Shi, Zhengxiang; Li, Baoming; Wang, Chaoyuan; Zhang, Guoqiang; Kristensen, Simon
2016-07-01
To investigate the impacts of major factors on carbon loss via gaseous emissions, carbon dioxide (CO2) and methane (CH4) emissions from the ground of open dairy lots were tested by a scale model experiment at various air temperatures (15, 25, and 35 °C), surface velocities (0.4, 0.7, 1.0, and 1.2 m sec(-1)), and floor types (unpaved soil floor and brick-paved floor) in controlled laboratory conditions using the wind tunnel method. Generally, CO2 and CH4 emissions were significantly enhanced with the increase of air temperature and velocity (P < 0.05). Floor type had different effects on the CO2 and CH4 emissions, which were also affected by air temperature and soil characteristics of the floor. Although different patterns were observed on CH4 emission from the soil and brick floors at different air temperature-velocity combinations, statistical analysis showed no significant difference in CH4 emissions from different floors (P > 0.05). For CO2, similar emissions were found from the soil and brick floors at 15 and 25 °C, whereas higher rates were detected from the brick floor at 35 °C (P < 0.05). Results showed that CH4 emission from the scale model was exponentially related to CO2 flux, which might be helpful in CH4 emission estimation from manure management. Gaseous emissions from the open lots are largely dependent on outdoor climate, floor systems, and management practices, which are quite different from those indoors. This study assessed the effects of floor types and air velocities on CO2 and CH4 emissions from the open dairy lots at various temperatures by a wind tunnel. It provided some valuable information for decision-making and further studies on gaseous emissions from open lots.
25. Similar view of lobby area on first floor transmitter ...
25. Similar view of lobby area on first floor transmitter building no. 102 looking at door in photograph AK-30-A-24 in closed position showing locking system and restricted access notification. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK
NASA Technical Reports Server (NTRS)
Thate, Robert
2012-01-01
The modular flooring system (MFS) was developed to provide a portable, modular, durable carpeting solution for NASA fs Robotics Alliance Project fs (RAP) outreach efforts. It was also designed to improve and replace a modular flooring system that was too heavy for safe use and transportation. The MFS was developed for use as the flooring for various robotics competitions that RAP utilizes to meet its mission goals. One of these competitions, the FIRST Robotics Competition (FRC), currently uses two massive rolls of broadloom carpet for the foundation of the arena in which the robots are contained during the competition. The area of the arena is approximately 30 by 72 ft (approximately 9 by 22 m). This carpet is very cumbersome and requires large-capacity vehicles, and handling equipment and personnel to transport and deploy. The broadloom carpet sustains severe abuse from the robots during a regular three-day competition, and as a result, the carpet is not used again for competition. Similarly, broadloom carpets used for trade shows at convention centers around the world are typically discarded after only one use. This innovation provides a green solution to this wasteful practice. Each of the flooring modules in the previous system weighed 44 lb (.20 kg). The improvements in the overall design of the system reduce the weight of each module by approximately 22 lb (.10 kg) (50 %), and utilize an improved "module-to-module" connection method that is superior to the previous system. The MFS comprises 4-by-4-ft (.1.2-by- 1.2-m) carpet module assemblies that utilize commercially available carpet tiles that are bonded to a lightweight substrate. The substrate surface opposite from the carpeted surface has a module-to-module connecting interface that allows for the modules to be connected, one to the other, as the modules are constructed. This connection is hidden underneath the modules, creating a smooth, co-planar flooring surface. The modules are stacked and strapped onto durable, commercially available drywall carts for storage and/or transportation. This method of storage and transportation makes it very convenient and safe when handling large quantities of modules.
Neonates in Ahmedabad, India, during the 2010 heat wave: a climate change adaptation study.
Kakkad, Khyati; Barzaga, Michelle L; Wallenstein, Sylvan; Azhar, Gulrez Shah; Sheffield, Perry E
2014-01-01
Health effects from climate change are an international concern with urban areas at particular risk due to urban heat island effects. The burden of disease on vulnerable populations in non-climate-controlled settings has not been well studied. This study compared neonatal morbidity in a non-air-conditioned hospital during the 2010 heat wave in Ahmedabad to morbidity in the prior and subsequent years. The outcome of interest was neonatal intensive care unit (NICU) admissions for heat. During the months of April, May, and June of 2010, 24 NICU admissions were for heat versus 8 and 4 in 2009 and 2011, respectively. Both the effect of moving the maternity ward and the effect of high temperatures were statistically significant, controlling for each other. Above 42 degrees Celsius, each daily maximum temperature increase of a degree was associated with 43% increase in heat-related admissions (95% CI 9.2-88%). Lower floor location of the maternity ward within hospital which occurred after the 2010 heat wave showed a protective effect. These findings demonstrate the importance of simple surveillance measures in motivating a hospital policy change for climate change adaptation-here relocating one ward-and the potential increasing health burden of heat in non-climate-controlled institutions on vulnerable populations.
Pressure gradient effects on heat transfer to reusable surface insulation tile-array gaps
NASA Technical Reports Server (NTRS)
Throckmorton, D. A.
1975-01-01
An experimental investigation was performed to determine the effect of pressure gradient on the heat transfer within space shuttle reusable surface insulation (RSI) tile-array gaps under thick, turbulent boundary-layer conditions. Heat-transfer and pressure measurements were obtained on a curved array of full-scale simulated RSI tiles in a tunnel-wall boundary layer at a nominal free-stream Mach number and free-stream Reynolds numbers. Transverse pressure gradients of varying degree were induced over the model surface by rotating the curved array with respect to the flow. Definition of the tunnel-wall boundary-layer flow was obtained by measurement of boundary-layer pitot pressure profiles, wall pressure, and heat transfer. Flat-plate heat-transfer data were correlated and a method was derived for prediction of heat transfer to a smooth curved surface in the highly three-dimensional tunnel-wall boundary-layer flow. Pressure on the floor of the RSI tile-array gap followed the trends of the external surface pressure. Heat transfer to the surface immediately downstream of a transverse gap is higher than that for a smooth surface at the same location. Heating to the wall of a transverse gap, and immediately downstream of it, at its intersection with a longitudinal gap is significantly greater than that for the simple transverse gap.
Neonates in Ahmedabad, India, during the 2010 Heat Wave: A Climate Change Adaptation Study
Kakkad, Khyati; Barzaga, Michelle L.; Wallenstein, Sylvan; Sheffield, Perry E.
2014-01-01
Health effects from climate change are an international concern with urban areas at particular risk due to urban heat island effects. The burden of disease on vulnerable populations in non-climate-controlled settings has not been well studied. This study compared neonatal morbidity in a non-air-conditioned hospital during the 2010 heat wave in Ahmedabad to morbidity in the prior and subsequent years. The outcome of interest was neonatal intensive care unit (NICU) admissions for heat. During the months of April, May, and June of 2010, 24 NICU admissions were for heat versus 8 and 4 in 2009 and 2011, respectively. Both the effect of moving the maternity ward and the effect of high temperatures were statistically significant, controlling for each other. Above 42 degrees Celsius, each daily maximum temperature increase of a degree was associated with 43% increase in heat-related admissions (95% CI 9.2–88%). Lower floor location of the maternity ward within hospital which occurred after the 2010 heat wave showed a protective effect. These findings demonstrate the importance of simple surveillance measures in motivating a hospital policy change for climate change adaptation—here relocating one ward—and the potential increasing health burden of heat in non-climate-controlled institutions on vulnerable populations. PMID:24734050
NASA Technical Reports Server (NTRS)
1978-01-01
Like nature's honeycomb, foam is a structure of many-sided cells, apparently solid but actually only three percent material and 97 percent air. Foam is made by a heat-producing chemical reaction which expands a plastic material in a manner somewhat akin to the heat-induced rising of a loaf of bread. The resulting structure of interconnected cells is flexible yet strong and extremely versatile in applicati6n. Foam can, for example, be a sound absorber in one form, while in another it allows sound to pass through it. It can be a very soft powder puff material and at the same time a highly abrasive scrubber. A sampling of foam uses includes stereo speaker grilles, applying postage meter ink, filtering lawnmower carburetor air; deadening noise in trucks and tractors, applying cosmetics, releasing fabric softener and antistatic agents in home clothes dryers, painting, filtering factory heating and ventilating systems, shining shoes, polishing cars, sponge-mopping floors, acting as pre-operative surgical scrubbers-the list is virtually limitless. The process by which foam is made produces "windows," thin plastic membranes connecting the cell walls. Windowed foam is used in many applications but for certain others-filtering, for example-it is desirable to have a completely open network. Scott Paper Company's Foam Division, Chester, Pennsylvania, improved a patented method of "removing the windows," to create an open structure that affords special utility in filtering applications. NASA technology contributed to Scott's improvement.
9. VIEW OF FLOOR 2 LOOKING EAST; SHOWS GREAT SPUR ...
9. VIEW OF FLOOR 2 LOOKING EAST; SHOWS GREAT SPUR WHEEL AND TWO STONE NUTS, AND THE CHUTES, HOPPERS, HORSES AND SHOES OF THE GRAIN FEED SYSTEM - Hook Windmill, North Main Street at Pantigo Road, East Hampton, Suffolk County, NY
15. FIRST FLOOR APARTMENT LIVING ROOM INTERIOR. OPEN DOORWAY AT ...
15. FIRST FLOOR APARTMENT LIVING ROOM INTERIOR. OPEN DOORWAY AT PHOTO CENTER OPENS TO KITCHEN. OPEN DOORWAY AT PHOTO LEFT OPENS TO BATHROOM. VIEW TO NORTHWEST. - Lee Vining Creek Hydroelectric System, Triplex Cottage, Lee Vining Creek, Lee Vining, Mono County, CA
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-09
... equity trading system. The Exchange ceased operation of the technology used to operate XLE on October 24... cleaning, HVAC and general maintenance. All other floor members would be assessed the Floor Facility Fee of...
Clay mineral formation and transformation in rocks and soils
Eberl, D.D.
1983-01-01
Three mechanisms for clay mineral formation (inheritance, neoformation, and transformation) operating in three geological environments (weathering, sedimentary, and diagenetic-hydrothermal) yield nine possibilities for the origin of clay minerals in nature. Several of these possibilities are discussed in terms of the rock cycle. The mineralogy of clays neoformed in the weathering environment is a function of solution chemistry, with the most dilute solutions favoring formation of the least soluble clays. After erosion and transportation, these clays may be deposited on the ocean floor in a lateral sequence that depends on floccule size. Clays undergo little reaction in the ocean, except for ion exchange and the neoformation of smectite; therefore, most clays found on the ocean floor are inherited from adjacent continents. Upon burial and heating, however, dioctahedral smectite reacts in the diagenetic environment to yield mixed-layer illite-smectite, and finally illite. With uplift and weathering, the cycle begins again. Refs.
Budget impact analysis of insulin therapies and associated delivery systems.
Lee, Lauren J; Smolen, Lee J; Klein, Timothy M; Foster, Shonda A; Whiteman, Doug; Jorgenson, James A; Hultgren, Steve
2012-06-01
A budget impact analysis of insulin therapies and associated delivery systems is presented. Based on inputted procurement totals, per-item costs (based on 2011 average wholesale price), insulin distribution system (floor stock or individual patient supply), waste, and treatment protocols for a specified time frame, the budget impact model approximated the number of patients treated with subcutaneous insulin, costs, utilization, waste, and injection mechanism (pen safety needle or syringe) costs. To calculate net changes, results of one-year 3-mL vial use were subtracted from one-year 10-mL vial or 3-mL pen use. Switching from a 10-mL vial to a 3-mL vial was associated with reductions in both costs and waste. The net reductions in costs and waste ranged from $15,482 and 120,000 IU, respectively, for floor-stock 10-mL vial to floor-stock 3-mL vial conversion to $871,548 and 6,750,000 IU, respectively, for individual patient supply 10-mL vial to floor-stock 3-mL vial conversion. Switching from floor-stock 10-mL vials to individual patient supply 3-mL vials increased costs and waste by $164,659 and 1,275,000 IU, respectively. Converting from individual patient supply 3-mL pens to individual patient supply 3-mL vials reduced costs by $117,236 but did not decrease waste. A budget impact analysis of the conversion of either 10-mL insulin vials or 3-mL insulin pens to 3-mL insulin vials found reductions in both cost and waste, except when converting from floor-stock 10-mL vials to individual patient supply 3-mL vials.
2010-01-01
Background Stair climbing up and down is an essential part of everyday's mobility. To enable wheelchair-dependent patients the repetitive practice of this task, a novel gait robot, G-EO-Systems (EO, Lat: I walk), based on the end-effector principle, has been designed. The trajectories of the foot plates are freely programmable enabling not only the practice of simulated floor walking but also stair climbing up and down. The article intended to compare lower limb muscle activation patterns of hemiparetic subjects during real floor walking and stairs climbing up, and during the corresponding simulated conditions on the machine, and secondly to demonstrate gait improvement on single case after training on the machine. Methods The muscle activation pattern of seven lower limb muscles of six hemiparetic patients during free and simulated walking on the floor and stair climbing was measured via dynamic electromyography. A non-ambulatory, sub-acute stroke patient additionally trained on the G-EO-Systems every workday for five weeks. Results The muscle activation patterns were comparable during the real and simulated conditions, both on the floor and during stair climbing up. Minor differences, concerning the real and simulated floor walking conditions, were a delayed (prolonged) onset (duration) of the thigh muscle activation on the machine across all subjects. Concerning stair climbing conditions, the shank muscle activation was more phasic and timely correct in selected patients on the device. The severely affected subject regained walking and stair climbing ability. Conclusions The G-EO-Systems is an interesting new option in gait rehabilitation after stroke. The lower limb muscle activation patterns were comparable, a training thus feasible, and the positive case report warrants further clinical studies. PMID:20584307
Hesse, Stefan; Waldner, Andreas; Tomelleri, Christopher
2010-06-28
Stair climbing up and down is an essential part of everyday's mobility. To enable wheelchair-dependent patients the repetitive practice of this task, a novel gait robot, G-EO-Systems (EO, Lat: I walk), based on the end-effector principle, has been designed. The trajectories of the foot plates are freely programmable enabling not only the practice of simulated floor walking but also stair climbing up and down. The article intended to compare lower limb muscle activation patterns of hemiparetic subjects during real floor walking and stairs climbing up, and during the corresponding simulated conditions on the machine, and secondly to demonstrate gait improvement on single case after training on the machine. The muscle activation pattern of seven lower limb muscles of six hemiparetic patients during free and simulated walking on the floor and stair climbing was measured via dynamic electromyography. A non-ambulatory, sub-acute stroke patient additionally trained on the G-EO-Systems every workday for five weeks. The muscle activation patterns were comparable during the real and simulated conditions, both on the floor and during stair climbing up. Minor differences, concerning the real and simulated floor walking conditions, were a delayed (prolonged) onset (duration) of the thigh muscle activation on the machine across all subjects. Concerning stair climbing conditions, the shank muscle activation was more phasic and timely correct in selected patients on the device. The severely affected subject regained walking and stair climbing ability. The G-EO-Systems is an interesting new option in gait rehabilitation after stroke. The lower limb muscle activation patterns were comparable, a training thus feasible, and the positive case report warrants further clinical studies.
2014-05-15
of the following tasks: sweep floors daily, mop floors with soap and water one time per week, wax floors one time per quarter, remove trash from...officer, nor does he/she hold any contracting authority. The FAR specifically states that a COR “has no authority to make any commitments or...key requirements to make sure everyone has the same view of the performance requirements. The customer states that they want the vendor to check
2014-06-01
sweep floors daily, mop floors with soap and water one time per week, wax floors one time per quarter, remove trash from garbage bins every Thursday...authority. The FAR specifically states that a COR “has no authority to make any commitments or changes that affect price, quality, quantity, delivery, or...to define key requirements to make sure everyone has the same view of the performance requirements. The customer states that they want the vendor
Super Boiler: Packed Media/Transport Membrane Boiler Development and Demonstration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liss, William E; Cygan, David F
2013-04-17
Gas Technology Institute (GTI) and Cleaver-Brooks developed a new gas-fired steam generation system the Super Boiler for increased energy efficiency, reduced equipment size, and reduced emissions. The system consists of a firetube boiler with a unique staged furnace design, a two-stage burner system with engineered internal recirculation and inter-stage cooling integral to the boiler, unique convective pass design with extended internal surfaces for enhanced heat transfer, and a novel integrated heat recovery system to extract maximum energy from the flue gas. With these combined innovations, the Super Boiler technical goals were set at 94% HHV fuel efficiency, operation on naturalmore » gas with <5 ppmv NOx (referenced to 3%O2), and 50% smaller than conventional boilers of similar steam output. To demonstrate these technical goals, the project culminated in the industrial demonstration of this new high-efficiency technology on a 300 HP boiler at Clement Pappas, a juice bottler located in Ontario, California. The Super Boiler combustion system is based on two stage combustion which combines air staging, internal flue gas recirculation, inter-stage cooling, and unique fuel-air mixing technology to achieve low emissions rather than external flue gas recirculation which is most commonly used today. The two-stage combustion provides lower emissions because of the integrated design of the boiler and combustion system which permit precise control of peak flame temperatures in both primary and secondary stages of combustion. To reduce equipment size, the Super Boiler's dual furnace design increases radiant heat transfer to the furnace walls, allowing shorter overall furnace length, and also employs convective tubes with extended surfaces that increase heat transfer by up to 18-fold compared to conventional bare tubes. In this way, a two-pass boiler can achieve the same efficiency as a traditional three or four-pass firetube boiler design. The Super Boiler is consequently up to 50% smaller in footprint, has a smaller diameter, and is up to 50% lower in weight, resulting in very compact design with reduced material cost and labor costs, while requiring less boiler room floor space. For enhanced energy efficiency, the heat recovery system uses a transport membrane condenser (TMC), a humidifying air heater (HAH), and a split-stage economizer to extract maximum energy from the flue gas. The TMC is a new innovation that pulls a major portion of water vapor produced by the combustion process from the flue gases along with its sensible and latent heat. This results in nearly 100% transfer of heat to the boiler feed water. The HAH improves the effectiveness of the TMC, particularly in steam systems that do not have a large amount of cold makeup water. In addition, the HAH humidifies the combustion air to reduce NOx formation. The split-stage economizer preheats boiler feed water in the same way as a conventional economizer, but extracts more heat by working in tandem with the TMC and HAH to reduce flue gas temperature. These components are designed to work synergistically to achieve energy efficiencies of 92-94% which is 10-15% higher than today's typical firetube boilers.« less
Equilibrium polymerization models of re-entrant self-assembly
NASA Astrophysics Data System (ADS)
Dudowicz, Jacek; Douglas, Jack F.; Freed, Karl F.
2009-04-01
As is well known, liquid-liquid phase separation can occur either upon heating or cooling, corresponding to lower and upper critical solution phase boundaries, respectively. Likewise, self-assembly transitions from a monomeric state to an organized polymeric state can proceed either upon increasing or decreasing temperature, and the concentration dependent ordering temperature is correspondingly called the "floor" or "ceiling" temperature. Motivated by the fact that some phase separating systems exhibit closed loop phase boundaries with two critical points, the present paper analyzes self-assembly analogs of re-entrant phase separation, i.e., re-entrant self-assembly. In particular, re-entrant self-assembly transitions are demonstrated to arise in thermally activated equilibrium self-assembling systems, when thermal activation is more favorable than chain propagation, and in equilibrium self-assembly near an adsorbing boundary where strong competition exists between adsorption and self-assembly. Apparently, the competition between interactions or equilibria generally underlies re-entrant behavior in both liquid-liquid phase separation and self-assembly transitions.
24. SECOND FLOOR EAST SIDE APARTMENT LIVING ROOM INTERIOR SHOWING ...
24. SECOND FLOOR EAST SIDE APARTMENT LIVING ROOM INTERIOR SHOWING DOORWAY INTO KITCHEN AT PHOTO CENTER LEFT AND OPEN DOORWAY INTO BATHROOM AT PHOTO RIGHT. VIEW TO SOUTHWEST. - Lee Vining Creek Hydroelectric System, Triplex Cottage, Lee Vining Creek, Lee Vining, Mono County, CA
32. SECOND FLOOR WEST SIDE APARTMENT LIVING ROOM INTERIOR SHOWING ...
32. SECOND FLOOR WEST SIDE APARTMENT LIVING ROOM INTERIOR SHOWING DOORWAY INTO KITCHEN AT PHOTO CENTER RIGHT, AND OPEN DOORWAY IN BATHROOM AT PHOTO LEFT. VIEW TO SOUTHWEST. - Lee Vining Creek Hydroelectric System, Triplex Cottage, Lee Vining Creek, Lee Vining, Mono County, CA
42. Fixed Span; General View of the Floor Beam, Stringer, ...
42. Fixed Span; General View of the Floor Beam, Stringer, & Lateral Bracing System; looking S. (from near to far: 6L & R, 5L & R, 4 L & R). - Pacific Shortline Bridge, U.S. Route 20,spanning Missouri River, Sioux City, Woodbury County, IA
43. FLOOR PLAN OF POWER HOUSE, EXHIBIT L, SANTA ANA ...
43. FLOOR PLAN OF POWER HOUSE, EXHIBIT L, SANTA ANA RIVER NO. 2 PROJECT, APR. 30, 1945. SCE drawing no. 523643 (sheet no. 14; for filing with Federal Power Commission). - Santa Ana River Hydroelectric System, SAR-2 Powerhouse, Redlands, San Bernardino County, CA
37. SECOND FLOOR WEST SIDE APARTMENT EAST BEDROOM INTERIOR SHOWING ...
37. SECOND FLOOR WEST SIDE APARTMENT EAST BEDROOM INTERIOR SHOWING PAIRED 6-LIGHT OVER 6-LIGHT DOUBLE-HUNG, WOOD-FRAME WINDOWS ON NORTH WALL. VIEW TO NORTHEAST. - Lee Vining Creek Hydroelectric System, Triplex Cottage, Lee Vining Creek, Lee Vining, Mono County, CA
Distribution and Room Air Mixing Risks to Retrofitted Homes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burdick, A.
2014-12-01
An energy efficiency upgrade reduces a home’s heating and cooling load. If the load reduction is great enough and the heating, ventilation, and air conditioning system warrants replacement, that system is often upgraded with a more efficient, lower capacity system that meets the load of the upgraded house. For a single-story house with floor supply air diffusers, the ducts often are removed and upgraded. For houses with ducts that are embedded in walls, the cost of demolition precludes the replacement of ducts. The challenge with the use of existing ducts is that the reduced airflow creates a decreased throw atmore » the supply registers, and the supply air and room air do not mix well, leading to potential thermal comfort complaints. This project investigates this retrofit scenario. The issues and solutions discussed here are relevant to all climate zones, with emphasis on climates that require cooling. In this project, IBACOS performed load calculations for a two-story 1960s house and characterized duct sizes and layouts based on industry “rules of thumb” (Herk et al. 2014). The team performed duct-sizing calculations for unaltered ducts and post-retrofit airflows and examined airflow velocities and pressure changes with respect to various factors. The team then used a mocked-up duct and register setup to measure the characteristics of isothermal air—to reduce the effects of buoyancy from the observations—passing through the duct and leaving the register.« less
Distortion of Digital Image Correlation (DIC) Displacements and Strains from Heat Waves
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jones, E. M. C.; Reu, P. L.
“Heat waves” is a colloquial term used to describe convective currents in air formed when different objects in an area are at different temperatures. In the context of Digital Image Correlation (DIC) and other optical-based image processing techniques, imaging an object of interest through heat waves can significantly distort the apparent location and shape of the object. We present that there are many potential heat sources in DIC experiments, including but not limited to lights, cameras, hot ovens, and sunlight, yet error caused by heat waves is often overlooked. This paper first briefly presents three practical situations in which heatmore » waves contributed significant error to DIC measurements to motivate the investigation of heat waves in more detail. Then the theoretical background of how light is refracted through heat waves is presented, and the effects of heat waves on displacements and strains computed from DIC are characterized in detail. Finally, different filtering methods are investigated to reduce the displacement and strain errors caused by imaging through heat waves. The overarching conclusions from this work are that errors caused by heat waves are significantly higher than typical noise floors for DIC measurements, and that the errors are difficult to filter because the temporal and spatial frequencies of the errors are in the same range as those of typical signals of interest. In conclusion, eliminating or mitigating the effects of heat sources in a DIC experiment is the best solution to minimizing errors caused by heat waves.« less
Distortion of Digital Image Correlation (DIC) Displacements and Strains from Heat Waves
Jones, E. M. C.; Reu, P. L.
2017-11-28
“Heat waves” is a colloquial term used to describe convective currents in air formed when different objects in an area are at different temperatures. In the context of Digital Image Correlation (DIC) and other optical-based image processing techniques, imaging an object of interest through heat waves can significantly distort the apparent location and shape of the object. We present that there are many potential heat sources in DIC experiments, including but not limited to lights, cameras, hot ovens, and sunlight, yet error caused by heat waves is often overlooked. This paper first briefly presents three practical situations in which heatmore » waves contributed significant error to DIC measurements to motivate the investigation of heat waves in more detail. Then the theoretical background of how light is refracted through heat waves is presented, and the effects of heat waves on displacements and strains computed from DIC are characterized in detail. Finally, different filtering methods are investigated to reduce the displacement and strain errors caused by imaging through heat waves. The overarching conclusions from this work are that errors caused by heat waves are significantly higher than typical noise floors for DIC measurements, and that the errors are difficult to filter because the temporal and spatial frequencies of the errors are in the same range as those of typical signals of interest. In conclusion, eliminating or mitigating the effects of heat sources in a DIC experiment is the best solution to minimizing errors caused by heat waves.« less
31. View of mezzanine floor level in transmitter building no. ...
31. View of mezzanine floor level in transmitter building no. 102 showing various electronic central indicator panel to control building air conditioning, steam pressure, supply temperature, discharge temperature, supply pressure, transformer vault status, and radome conditioning system. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK
Blackwood, C.B.; Waldrop, M.P.; Zak, D.R.; Sinsabaugh, R. L.
2007-01-01
The fungal community of the forest floor was examined as the cause of previously reported increases in soil organic matter due to experimental N deposition in ecosystems producing predominantly high-lignin litter, and the opposite response in ecosystems producing low-lignin litter. The mechanism proposed to explain this phenomenon was that white-rot basidiomycetes are more important in the degradation of high-lignin litter than of low-lignin litter, and that their activity is suppressed by N deposition. We found that forest floor mass in the low-lignin sugar-maple dominated system decreased in October due to experimental N deposition, whereas forest floor mass of high-lignin oak-dominated ecosystems was unaffected by N deposition. Increased relative abundance of basidiomycetes in high-lignin forest floor was confirmed by denaturing gradient gel electrophoresis (DGGE) and sequencing. Abundance of basidiomycete laccase genes, encoding an enzyme used by white-rot basidiomycetes in the degradation of lignin, was 5-10 times greater in high-lignin forest floor than in low-lignin forest floor. While the differences between the fungal communities in different ecosystems were consistent with the proposed mechanism, no significant effects of N deposition were detected on DGGE profiles, laccase gene abundance, laccase length heterogeneity profiles, or phenol oxidase activity. Our observations indicate that the previously detected accumulation of soil organic matter in the high-lignin system may be driven by effects of N deposition on organisms in the mineral soil, rather than on organisms residing in the forest floor. However, studies of in situ gene expression and temporal and spatial variability within forest floor communities will be necessary to further relate the ecosystem dynamics of organic carbon to microbial communities and atmospheric N deposition. ?? 2007 The Authors; Journal compilation ?? 2007 Society for Applied Microbiology and Blackwell Publishing Ltd.
Development and Testing of a Mobile Platform for Tank Remediation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nance, T.A.
2001-01-16
The Department of Energy (DOE) is committed to removing millions of gallons of high level radioactive waste from waste storage tanks at the Savannah River Site (SRS). SRS was the first site in the DOE complex to have emptied and closed high level waste tanks. Tank closure at the Site is now progressing to tanks containing waste composed of liquid and large deposits of solids, including a tank that has a potential ''heel''. A heel is a hardened mass of solid waste material spread across the tank bottom. Tank closure requires breaking up this heel and moving the material tomore » the intake of a pumping system for transfer from the tank. In the past, overhead spray systems have been used with some success at moving waste. But the limited number of risers restricts the coverage area of the overhead spray system. Therefore, a floor- level spray system will be used to separate manageable size chunks of the material from the heel. The chunks will be guided into the pump's intake to be remove from the tank. The floor-level spray system movement will be accomplished by using a mobile platform, a crawler, which provides transport to nearly every point on the tank floor. Transport of the spray system will allow the system to ''corral'' the waste away from the tank walls and control the movement of the material across the tank floor. Because the available access riser is small, and a wide crawler platform is required to support the spray system, the crawler's frame must fold to enter the tank. After entry into the tank, the crawler unfolds on the tank floor using the crawler drive tracks to expand the frame and position the mobile platform under the entry riser. The spray system will then be lowered separately through the entry riser and mated onto the crawler on the tank floor. The crawler and spray system are tethered and controlled remotely by personnel at the control station. Motorized cable reels will also be remotely controlled to pay out, retrieve, and manage the tethers as the mobile platform moves the spray system across the tank floor. Both the crawler and spray systems are designed to be retrievable. Development of the tank cleaning system was evaluated using a performance test program. The tests evaluated the spray system dynamics, the crawler's fit through the riser, the crawler landing in mocked up tank with simulant, the crawler's traction, and the crawler and spray system mating. Initial testing verified the crawler platform was compatible with the dynamics produced by the spray system. The riser fit test confirmed that a dedicated riser is required for deployment of the crawler and the spray system. The crawler traction test defined the capabilities of the crawler at different levels of simulant. Deployment testing through a mockup riser verified the basic system processes. Finally, testing of the complete system in a full-scale mockup with sludge simulant was performed to evaluate the tank cleaning ability of the crawler. This paper describes th e tank conditions, the tank closure process, the development of the crawler and spray system, and the testing program and results used to evaluate the mobile platform and spray system.« less
Wang, W; Erf, G F; Wideman, R F
2002-11-01
Intravenous endotoxin has been shown to trigger a delayed pulmonary hypertensive response that varies widely in magnitude and duration among individual broilers. It was proposed that this individual variability may reflect immunological differences acquired during previous respiratory challenges that might have subsequently altered the endotoxin-initiated biochemical cascade. In Experiment 1, we tested the hypothesis that, when compared with broilers reared in clean stainless steel cages (Cage group), broilers reared on floor litter (Floor group) should experience a greater respiratory challenge and therefore may consistently exhibit a more enhanced pulmonary hypertensive response to intravenous endotoxin. Birds in the Cage group were grown in stainless steel cages at a low density (72 birds/8 m2 chamber), and fecal and dander materials were removed daily. Birds in the Floor group were reared on wood-shavings litter at a higher density (110 birds/8 m2 chamber). Pulmonary and systemic mean arterial pressures and blood-gas values were evaluated prior to and following the intravenous administration of 1 mg Salmonella typhimurium endotoxin. Broilers in the Floor and Cage groups exhibited pulmonary hypertensive responses to endotoxin that were very similar in terms of time of onset, duration, and magnitude, as well as variability in the response among individuals. Systemic hypotension also developed similarly in both groups following endotoxin injection. Blood-gas values indicated that the partial pressure of CO2 and the HCO3- concentration in arterial blood were higher (P < 0.05) in the Floor group than in the Cage group prior to and subsequent to the endotoxin injection. In Experiment 2, we reevaluated the effect of a dirty vs. a clean environment on blood-gas values using a different strain of broilers, and confirmed the negative impact of floor rearing on blood-gas values. We conclude that broilers reared on the floor inhaled litter dust and noxious fumes, which impaired pulmonary gas exchange and increased the arterial partial pressure of CO2 when compared with broilers reared in clean stainless steel cages. Nevertheless, the pulmonary hypertensive response to endotoxin did not differ between broilers reared on the floor and those in cages.
Constructing an Indoor Floor Plan Using Crowdsourcing Based on Magnetic Fingerprinting
Zhao, Fang; Jiang, Mengling; Ma, Hao; Zhang, Yuexia
2017-01-01
A large number of indoor positioning systems have recently been developed to cater for various location-based services. Indoor maps are a prerequisite of such indoor positioning systems; however, indoor maps are currently non-existent for most indoor environments. Construction of an indoor map by external experts excludes quick deployment and prevents widespread utilization of indoor localization systems. Here, we propose an algorithm for the automatic construction of an indoor floor plan, together with a magnetic fingerprint map of unmapped buildings using crowdsourced smartphone data. For floor plan construction, our system combines the use of dead reckoning technology, an observation model with geomagnetic signals, and trajectory fusion based on an affinity propagation algorithm. To obtain the indoor paths, the magnetic trajectory data obtained through crowdsourcing were first clustered using dynamic time warping similarity criteria. The trajectories were inferred from odometry tracing, and those belonging to the same cluster in the magnetic trajectory domain were then fused. Fusing these data effectively eliminates the inherent tracking errors originating from noisy sensors; as a result, we obtained highly accurate indoor paths. One advantage of our system is that no additional hardware such as a laser rangefinder or wheel encoder is required. Experimental results demonstrate that our proposed algorithm successfully constructs indoor floor plans with 0.48 m accuracy, which could benefit location-based services which lack indoor maps. PMID:29156639
Obstacle Detection in Indoor Environment for Visually Impaired Using Mobile Camera
NASA Astrophysics Data System (ADS)
Rahman, Samiur; Ullah, Sana; Ullah, Sehat
2018-01-01
Obstacle detection can improve the mobility as well as the safety of visually impaired people. In this paper, we present a system using mobile camera for visually impaired people. The proposed algorithm works in indoor environment and it uses a very simple technique of using few pre-stored floor images. In indoor environment all unique floor types are considered and a single image is stored for each unique floor type. These floor images are considered as reference images. The algorithm acquires an input image frame and then a region of interest is selected and is scanned for obstacle using pre-stored floor images. The algorithm compares the present frame and the next frame and compute mean square error of the two frames. If mean square error is less than a threshold value α then it means that there is no obstacle in the next frame. If mean square error is greater than α then there are two possibilities; either there is an obstacle or the floor type is changed. In order to check if the floor is changed, the algorithm computes mean square error of next frame and all stored floor types. If minimum of mean square error is less than a threshold value α then flour is changed otherwise there exist an obstacle. The proposed algorithm works in real-time and 96% accuracy has been achieved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hughes, Patrick; Im, Piljae
2012-04-01
Geothermal heat pumps, sometimes called ground-source heat pumps (GSHPs), have been proven capable of significantly reducing energy use and peak demand in buildings. Conventional equipment for controlling the temperature and humidity of a building, or supplying hot water and fresh outdoor air, must exchange energy (or heat) with the building's outdoor environment. Equipment using the ground as a heat source and heat sink consumes less non-renewable energy (electricity and fossil fuels) because the earth is cooler than outdoor air in summer and warmer in winter. The most important barrier to rapid growth of the GSHP industry is high first costmore » of GSHP systems to consumers. The most common GSHP system utilizes a closed-loop ground heat exchanger. This type of GSHP system can be used almost anywhere. There is reason to believe that reducing the cost of closed-loop systems is the strategy that would achieve the greatest energy savings with GSHP technology. The cost premium of closed-loop GSHP systems over conventional space conditioning and water heating systems is primarily associated with drilling boreholes or excavating trenches, installing vertical or horizontal ground heat exchangers, and backfilling the excavations. This project investigates reducing the cost of horizontal closed-loop ground heat exchangers by installing them in the construction excavations, augmented when necessary with additional trenches. This approach applies only to new construction of residential and light commercial buildings or additions to such buildings. In the business-as-usual scenario, construction excavations are not used for the horizontal ground heat exchanger (HGHX); instead the HGHX is installed entirely in trenches dug specifically for that purpose. The potential cost savings comes from using the construction excavations for the installation of ground heat exchangers, thereby minimizing the need and expense of digging additional trenches. The term foundation heat exchanger (FHX) has been coined to refer exclusively to ground heat exchangers installed in the overcut around the basement walls. The primary technical challenge undertaken by this project was the development and validation of energy performance models and design tools for FHX. In terms of performance modeling and design, ground heat exchangers in other construction excavations (e.g., utility trenches) are no different from conventional HGHX, and models and design tools for HGHX already exist. This project successfully developed and validated energy performance models and design tools so that FHX or hybrid FHX/HGHX systems can be engineered with confidence, enabling this technology to be applied in residential and light commercial buildings. The validated energy performance model also addresses and solves another problem, the longstanding inadequacy in the way ground-building thermal interaction is represented in building energy models, whether or not there is a ground heat exchanger nearby. Two side-by-side, three-level, unoccupied research houses with walkout basements, identical 3,700 ft{sup 2} floor plans, and hybrid FHX/HGHX systems were constructed to provide validation data sets for the energy performance model and design tool. The envelopes of both houses are very energy efficient and airtight, and the HERS ratings of the homes are 44 and 45 respectively. Both houses are mechanically ventilated with energy recovery ventilators, with space conditioning provided by water-to-air heat pumps with 2 ton nominal capacities. Separate water-to-water heat pumps with 1.5 ton nominal capacities were used for water heating. In these unoccupied research houses, human impact on energy use (hot water draw, etc.) is simulated to match the national average. At House 1 the hybrid FHX/HGHX system was installed in 300 linear feet of excavation, and 60% of that was construction excavation (needed to construct the home). At House 2 the hybrid FHX/HGHX system was installed in 360 feet of excavation, 50% of which was construction excavation. There are six pipes in all excavations (three parallel circuits - out and back), and the multiple instances of FHX and/or HGHX are all connected in series. The working fluid is 20% by weight propylene glycol in water. Model and design tool development was undertaken in parallel with constructing the houses, installing instrumentation, and monitoring performance for a year. Several detailed numerical models for FHX were developed as part of the project. Essentially the project team was searching for an energy performance model accurate enough to achieve project objectives while also having sufficient computational efficiency for practical use in EnergyPlus. A 3-dimensional, dual-coordinate-system, finite-volume model satisfied these criteria and was included in the October 2011 EnergyPlus Version 7 public release after being validated against measured data.« less
31. PETIBONE SAND THROWING MACHINE BOX FLOOR GREY IRON FOUNDRY ...
31. PETIBONE SAND THROWING MACHINE BOX FLOOR GREY IRON FOUNDRY FORCES CONDITIONED MOLDING SAND, AT HIGH VELOCITY, INTO MOLDS TOO BIG TO BE MADE ON ONE OF THE CONVEYOR SYSTEMS. - Stockham Pipe & Fittings Company, Grey Iron Foundry, 4000 Tenth Avenue North, Birmingham, Jefferson County, AL
VIEW OF #2 EXCITER WITH GOVERNOR ON GENERATOR FLOOR. THIS ...
VIEW OF #2 EXCITER WITH GOVERNOR ON GENERATOR FLOOR. THIS EXCITER IS DRIVEN BY A HORIZONTAL KAPLAN WHEEL LOCATED ON OPPOSITE SIDE OF WALL IN WHEELROOM. PHOTO BY JET LOWE, HAER, 1995. - Elwha River Hydroelectric System, Elwha Hydroelectric Dam & Plant, Port Angeles, Clallam County, WA
29. SITE BUILDING 002 SCANNER BUILDING FLOOR 3A ...
29. SITE BUILDING 002 - SCANNER BUILDING - FLOOR 3A ("A" FACE) AT SYSTEM LAYOUT GRID 17. GENERAL OBLIQUE VIEW OF "A" FACE INTERIOR SHOWING RADAR EMITTER/ANTENNA INTERFACE ELECTRONICS. - Cape Cod Air Station, Technical Facility-Scanner Building & Power Plant, Massachusetts Military Reservation, Sandwich, Barnstable County, MA
16. FIRST FLOOR APARTMENT KITCHEN INTERIOR SHOWING OPEN DOORWAY TO ...
16. FIRST FLOOR APARTMENT KITCHEN INTERIOR SHOWING OPEN DOORWAY TO LIVING ROOM AND PAIRED 6-LIGHT OVER 6-LIGHT DOUBLE-HUNG, WOOD-FRAME WINDOWS OVER SINK. VIEW TO EAST. - Lee Vining Creek Hydroelectric System, Triplex Cottage, Lee Vining Creek, Lee Vining, Mono County, CA
Beaulieu, Harry J; Beaulieu, Serrita; Brown, Chris
2008-06-01
Phenyl mercuric acetate (PMA) historically has been used as a catalyst in polyurethane systems. In the 1950s-1970s, PMA was used as a catalyst in the 3M Tartan brand polyurethane flexible floors that were installed commonly in school gymnasiums. Mercury vapor is released into air above the surface of these floors. Sampling mercury in bulk flooring material and mercury vapor in air was conducted in nine Idaho schools in the spring of 2006. These evaluations were conducted in response to concerns by school officials that the floors could contain mercury and could release the mercury vapor into the air, presenting a potential health hazard for students, staff, and visitors. Controlled abatement was conducted in one school where remodeling would impact the mercury-bearing flexible gym floors ( approximately 9,000 ft(2) total). The controlled abatement consisted of containment of the work area with negative air technology; worker protection, including mercury-specific training, use of personal protective equipment, and biological and exposure monitoring; and environmental protection, including proper disposal of mercury-bearing hazardous waste material.
Gunnarsson, S; Keeling, L J; Svedberg, J
1999-03-01
1. Effects of rearing conditions on behavioural problems were investigated in a cohort study of commercial flocks of laying hens housed in 2 different loose housing systems. The sample population was 120 385 laying hens from 59 flocks of various hybrids at 21 different farms. 2. Logistic regression modelling was used to test the effects of selected factors on floor eggs, cloacal cannibalism and feather pecking. In addition to early access to perches or litter, models included hybrid, stocking density, group size, housing system, age at delivery, identical housing system at the rearing farm and at the production farm and, in models for floor eggs and cloacal cannibalism, nest area per hen. Odds ratios were calculated from the results of the models to allow risk assessment. 3. No significant correlations were found between the prevalence of floor eggs, cloacal cannibalism and feather pecking. 4. Access to perches from not later than the 4th week of age decreased the prevalence of floor eggs during the period from start-of-lay until 35 weeks of age, odds ratio 0-30 (P<0-001). Furthermore, early access to perches decreased the prevalence of cloacal cannibalism during the production period, odds ratio 0-46 (P=0.03). 5. No other factor had a significant effect in these models. Although it was not significant, early access to litter had a non-significant tendency to reduce the prevalence of feather pecking.
Tian, Jing; Yam, Caleb; Balasundaram, Gayathri; Wang, Hui; Gore, Aniket; Sampath, Karuna
2003-07-01
The floor plate, a specialized group of cells in the ventral midline of the neural tube of vertebrates, plays crucial roles in patterning the central nervous system. Recent work from zebrafish, chick, chick-quail chimeras and mice to investigate the development of the floor plate have led to several models of floor-plate induction. One model suggests that the floor plate is formed by inductive signalling from the notochord to the overlying neural tube. The induction is thought to be mediated by notochord-derived Sonic hedgehog (Shh), a secreted protein, and requires direct cellular contact between the notochord and the neural tube. Another model proposes a role for the organizer in generating midline precursor cells that produce floor plate cells independent of notochord specification, and proposes that floor plate specification occurs early, during gastrulation. We describe a temperature-sensitive mutation that affects the zebrafish Nodal-related secreted signalling factor, Cyclops, and use it to address the issue of when the floor plate is induced in zebrafish. Zebrafish cyclops regulates the expression of shh in the ventral neural tube. Although null mutations in cyclops result in the lack of the medial floor plate, embryos homozygous for the temperature-sensitive mutation have floor plate cells at the permissive temperature and lack floor plate cells at the restrictive temperature. We use this mutant allele in temperature shift-up and shift-down experiments to answer a central question pertaining to the timing of vertebrate floor plate induction. Abrogation of Cyc/Nodal signalling in the temperature-sensitive mutant embryos at various stages indicates that the floor plate in zebrafish is induced early in development, during gastrulation. In addition, continuous Cyclops signalling is required through gastrulation for a complete ventral neural tube throughout the length of the neuraxis. Finally, by modulation of Nodal signalling levels in mutants and in ectopic overexpression experiments, we show that, similar to the requirements for prechordal plate mesendoderm fates, uninterrupted and high levels of Cyclops signalling are required for induction and specification of a complete ventral neural tube.
2014-04-03
CAPE CANAVERAL, Fla. – The Ground Systems Development and Operations Program is overseeing efforts to create a new multi-user firing room in Firing Room 4 in the Launch Control Center at NASA's Kennedy Space Center in Florida. The main floor consoles, cabling and wires below the floor and ceiling tiles have been removed. Sub-flooring has been installed and the room is marked off to create four separate rooms on the main floor. The design of Firing Room 4 will incorporate five control room areas that are flexible to meet current and future NASA and commercial user requirements. The equipment and most of the consoles from Firing Room 4 were moved to Firing Room 2 for possible future reuse. Photo credit: NASA/Ben Smegelsky
Predictive models of energy consumption in multi-family housing in College Station, Texas
NASA Astrophysics Data System (ADS)
Ali, Hikmat Hummad
Patterns of energy consumption in apartment buildings are different than those in single-family houses. Apartment buildings have different physical characteristics, and their inhabitants have different demographic attributes. This study develops models that predict energy usage in apartment buildings in College Station. This is accomplished by analyzing and identifying the predictive variables that affect energy usage, studying the consumption patterns, and creating formulas based on combinations of these variables. According to the hypotheses and the specific research context, a cross-sectional design strategy is adopted. This choice implies analyses across variations within a sample of fourplex apartments in College Station. The data available for analysis include the monthly billing data along with the physical characteristics of the building, climate data for College Station, and occupant demographic characteristics. A simple random sampling procedure is adopted. The sample size of 176 apartments is drawn from the population in such a way that every possible sample has the same chance of being selected. Statistical methods used to interpret the data include univariate analysis (mean, standard deviation, range, and distribution of data), correlation analysis, regression analysis, and ANOVA (analyses of variance). The results show there are significant differences in cooling efficiency and actual energy consumption among different building types, but there are no significant differences in heating consumption. There are no significant differences in actual energy consumption between student and non-student groups or among ethnic groups. The findings indicate that there are significant differences in actual energy consumption among marital status groups and educational level groups. The multiple regression procedures show there is a significant relationship between normalized annual consumption and the combined variables of floor area, marital status, dead band, construction material, summer thermostat setting, heating, slope, and base load, as well as a relationship between cooling slope and the combined variables of share wall, floor level, summer thermostat setting, external wall, and American household. In addition, there is a significant relationship between heating slope and the combined variables of winter thermostat setting, market value, student, and rent. The results also indicate there is a relationship between base load and the combined variables of floor area, market value, age of the building, marital status, student, and summer thermostat setting.
34. SECOND FLOOR WEST SIDE APARTMENT KITCHEN INTERIOR. DOORWAY AT ...
34. SECOND FLOOR WEST SIDE APARTMENT KITCHEN INTERIOR. DOORWAY AT PHOTO LEFT LEADS TO PANTRY. GROUP OF THREE 6-LIGHT WOOD-FRAME CASEMENT WINDOWS OPEN TO WALKWAY AT REAR OF BUILDING. VIEW TO SOUTH. - Lee Vining Creek Hydroelectric System, Triplex Cottage, Lee Vining Creek, Lee Vining, Mono County, CA
30 CFR 822.12 - Protection of agricultural activities.
Code of Federal Regulations, 2011 CFR
2011-07-01
... alluvial valley floors; or (2) cause material damage to the quantity or quality of water in surface or underground water systems that supply alluvial valley floors. (b) Statutory exclusions. The prohibitions of... be of negligible impact on the farm's agricultural production; (3) To any surface coal mining and...
30 CFR 822.12 - Protection of agricultural activities.
Code of Federal Regulations, 2010 CFR
2010-07-01
... alluvial valley floors; or (2) cause material damage to the quantity or quality of water in surface or underground water systems that supply alluvial valley floors. (b) Statutory exclusions. The prohibitions of... be of negligible impact on the farm's agricultural production; (3) To any surface coal mining and...
36. SECOND FLOOR WEST SIDE APARTMENT EAST BEDROOM INTERIOR. OPEN ...
36. SECOND FLOOR WEST SIDE APARTMENT EAST BEDROOM INTERIOR. OPEN DOORWAY AT PHOTO LEFT CENTER LEADS TO CLOSET, AND OPEN DOORWAY AT PHOTO RIGHT CENTER LEADS TO LIVING ROOM. VIEW TO SOUTH. - Lee Vining Creek Hydroelectric System, Triplex Cottage, Lee Vining Creek, Lee Vining, Mono County, CA
23. SECOND FLOOR EAST SIDE APARTMENT LIVING ROOM INTERIOR. PAIRED ...
23. SECOND FLOOR EAST SIDE APARTMENT LIVING ROOM INTERIOR. PAIRED 4-LIGHT OVER 1-LIGHT DOUBLE-HUNG, WOOD-FRAME WINDOWS FLANK ENTRY DOOR. DOORWAY AT PHOTO RIGHT OPENS TO KITCHEN. VIEW TO SOUTHEAST. - Lee Vining Creek Hydroelectric System, Triplex Cottage, Lee Vining Creek, Lee Vining, Mono County, CA
38. SECOND FLOOR WEST SIDE APARTMENT WEST BEDROOM INTERIOR SHOWING ...
38. SECOND FLOOR WEST SIDE APARTMENT WEST BEDROOM INTERIOR SHOWING PAIRED 6-LIGHT OVER 6-LIGHT DOUBLE-HUNG, WOOD-FRAME WINDOWS ON WEST WALL AND OPEN DOORWAY TO LIVING ROOM. VIEW TO WEST. - Lee Vining Creek Hydroelectric System, Triplex Cottage, Lee Vining Creek, Lee Vining, Mono County, CA
33. SECOND FLOOR WEST SIDE APARTMENT KITCHEN INTERIOR. 6LIGHT PANEL ...
33. SECOND FLOOR WEST SIDE APARTMENT KITCHEN INTERIOR. 6-LIGHT PANEL DOOR AND 6-LIGHT CASEMENT WINDOW AT PHOTO CENTER AND PHOTO RIGHT RESPECTIVELY OPEN TO EXTERIOR STAIRWAY LANDING. VIEW TO WEST. - Lee Vining Creek Hydroelectric System, Triplex Cottage, Lee Vining Creek, Lee Vining, Mono County, CA
6. FLOOR 1; LOOKING WEST; SHOWS UNDERDRIFT SYSTEM, FOUR POSTS ...
6. FLOOR 1; LOOKING WEST; SHOWS UNDERDRIFT SYSTEM, FOUR POSTS SUPPORT BRIDGE BEAM FOR FOOT BEARING OF UPRIGHT SHAFT, SPUR PINION STONE NUTS SLIDE DOWN STONE SPINDLE TO ENGAGE, CENTRIFUGAL GOVERNOR IS MOUNTED ON A SEPARATE SPINDLE DRIVEN BY A BELT FROM THE STONE SPINDLE; ALSO SHOWN ARE THE GREAT SPUR WHEEL AND A LAYSHAFT RUNNING OFF A CROWN WHEEL JUST ABOVE THE GREAT SPUR WHEEL - Gardiner Windmill, East Hampton, Suffolk County, NY
Engineering and Design: Indoor Radon Prevention and Mitigation
1993-09-15
slabs on grade, capillary water barrier below floor slabs on grade, dampproofing or waterproofing and protection board on below grade walls, sealants in...will be lapped 12 inches and sealed with adhesives or pressure sensitive tape and sealed at foundation walls with mastic. Capillary water barrier will...Systems, Letter Codes B, C, and D. Sub- slab suction systems consist of 4 inch diameter perforated PVC pipe laid in the capillary water barrier below floor
NASA Astrophysics Data System (ADS)
Yu, Lu; Zhou, Jin; Mabu, Shingo; Hirasawa, Kotaro; Hu, Jinglu; Markon, Sandor
The Elevator Group Supervisory Control Systems (EGSCS) are the control systems that systematically manage three or more elevators in order to efficiently transport the passengers in buildings. Double-deck elevators, where two elevators are connected with each other, serve passengers at two consecutive floors simultaneously. Double-deck Elevator systems (DDES) become more complex in their behavior than conventional single-deck elevator systems (SDES). Recently, Artificial Intelligence (AI) technology has been used in such complex systems. Genetic Network Programming (GNP), a graph-based evolutionary method, has been applied to EGSCS and its advantages are shown in some papers. GNP can obtain the strategy of a new hall call assignment to the optimal elevator when it performs crossover and mutation operations to judgment nodes and processing nodes. Meanwhile, Destination Floor Guidance System (DFGS) is installed in DDES, so that passengers can also input their destinations at elevator halls. In this paper, we have applied GNP to DDES and compared DFGS with normal systems. The waiting time and traveling time of DFGS are all improved because of getting more information from DFGS. The simulations showed the effectiveness of the double-deck elevators with DFGS in different building traffics.
Novel safety floors do not influence early compensatory balance reactions in older adults.
Wright, Alexander D; Heckman, George A; McIlroy, William E; Laing, Andrew C
2014-01-01
Novel safety flooring systems are a promising approach for reducing fall-related injuries in seniors, as they have been demonstrated to substantially reduce impact severity during falls, while minimally impairing balance control in community-dwelling older women. This pilot study aimed to characterize the potential effects of flooring conditions on dynamic balance control in retirement home-dwellers with more limited mobility. A tether-release paradigm was used to simulate a trip-type perturbation in 15 seniors across five flooring surfaces (three novel safety floors and one carpet compared to institutional-grade resilient rolled-sheeting). Kinetic and kinematic data tracked the displacement profiles of the underfoot centre-of-pressure and whole-body centre-of-mass, which were used to characterize compensatory balance reactions. Difference tests (ANOVA) found that the onset of the compensatory balance reaction was not associated with floor condition, nor were the timing and magnitude of peak centre-of-pressure excursion (minimum margin of safety) and velocity. Accordingly, the minimum margin of safety of the centre-of-mass was not significantly different across floors. Equivalence tests supported these findings. This study provides evidence that the carpet and novel safety floors tested do not negatively influence characteristics of initial dynamic balance responses following a lean-and-release perturbation compared to an institutional-grade resilient rolled-sheeting surface. In combination with reports of substantial force attenuative properties during fall-related impacts, these findings support the promise of novel safety floors as a biomechanically effective strategy for reducing fall-related injuries. Crown Copyright © 2014. Published by Elsevier B.V. All rights reserved.
Validity of the Jump-and-Reach Test in Subelite Adolescent Handball Players.
Muehlbauer, Thomas; Pabst, Jan; Granacher, Urs; Büsch, Dirk
2017-05-01
Muehlbauer, T, Pabst, J, Granacher, U, and Büsch, D. Validity of the jump-and-reach test in subelite adolescent handball players. J Strength Cond Res 31(5): 1282-1289, 2017-The primary purpose of this study was to examine concurrent validity of the jump-and-reach (JaR) test using the Vertec system and a criterion device (i.e., Optojump system). In separate subanalyses, we investigated the influence of gym floor condition and athletes' sex on the validity of vertical jump height. Four hundred forty subelite adolescent female (n = 222, mean age: 14 ± 1 year, age range: 13-15 years) and male (n = 218, mean age: 15 ± 1 year, age range: 14-16 years) handball players performed the JaR test in gyms with region or point elastic floors. Maximal vertical jump height was simultaneously assessed using the Vertec and the Optojump systems. In general, significantly higher jump heights were obtained for the Vertec compared with the Optojump system (11.2 cm, Δ31%, Cohen's d = 2.58). The subanalyses revealed significantly larger jump heights for the Vertec compared with the Optojump system irrespective of gym floor condition and players' sex. The association between Optojump- and Vertec-derived vertical jump heights amounted to rP = 0.84, with a coefficient of determination (R) of 0.71. The subanalyses indicated significantly larger correlations in males (rP = 0.75, R = 0.56) than in females (rP = 0.63, R = 0.40). Yet, correlations were not significantly different between region (rP = 0.83, R = 0.69) as opposed to point elastic floor (rP = 0.87, R = 0.76). Our findings indicate that the 2 apparatuses cannot be used interchangeably. Consequently, gym floor and sex-specific regression equations were provided to estimate true (Optojump system) vertical jump height from Vertec-derived data.
30. SITE BUILDING 002 SCANNER BUILDING FLOOR 3A ...
30. SITE BUILDING 002 - SCANNER BUILDING - FLOOR 3A ("A" FACE) INTERIOR BETWEEN GRIDS 17-A1 AND 18-A1, SHOWING REAR OF RADAR EMITTER ELECTRONIC INTERFACE TERMINAL NO. 3147-20, "RECEIVER TRANSMITTER RADAR" MODULE. VIEW IS ALSO SHOWING BUILDING FIRE STOP MATERIAL AT BOTTOM OF FLOOR. NOTE: WALL SLOPES BOTTOM TO TOP INWARD; STRUCTURAL ELEMENT IN FOREGROUND. VIEW ALSO SHOWS PIPING GRID OF CHILLED WATER LINES FOR ELECTRONIC SYSTEMS COOLING. - Cape Cod Air Station, Technical Facility-Scanner Building & Power Plant, Massachusetts Military Reservation, Sandwich, Barnstable County, MA
Sensitization to epoxy resin systems in special flooring workers.
Condé-Salazar, L; Gonzalez de Domingo, M A; Guimaraens, D
1994-09-01
The use of new products in building and public works is increasing, among them being special floor coverings containing epoxy resins and derivatives. These are used principally in heavily frequented areas, such as shopping precincts, hospitals, civic centres, etc., due to their high resistance to wear and tear, environmental factors, etc. In the last 2 years, we have studied 15 cases of men sensitized to epoxy resin, or derivatives, who worked with special floorings. Speed of sensitization, severity of lesions, and localization to the hands, face and legs were characteristic.
Analysis of Marketing and Customer Satisfaction in Base Housing Communities of the Monterey Bay Area
2011-06-01
the U.S. Government. IRB Protocol number NPS.2010.0003- IR -EP7-A. 12a. DISTRIBUTION / AVAILABILITY STATEMENT Approved for public release...Reese, thank you for answering all my late-night phone calls and reminding me I should be working on my paper instead of venting. This report is...amenities include: ceiling fans, central heating, private balcony, hardwood floors, master bedroom suite, washer/ dryer hookups, media boxes for
NASA Astrophysics Data System (ADS)
Fedorovich, Evgeni; Kaiser, Rolf; Rau, Matthias; Plate, Erich
1996-05-01
Experiments on simulating the atmospheric convective boundary layer (CBL), capped by a temperature inversion and affected by surface shear, were carried out in the thermally stratified wind tunnel of the Institute of Hydrology and Water Resources, University of Karlsruhe. The tunnel is of the closed-circuit type, with a test section 10 m long, 1.5 m wide, and 1.5 m high. The return section of the tunnel is subdivided into 10 layers, each driven by its own fan and heating system. By this means, velocity and temperature profiles can be preshaped at the inlet of the test section, which allows for the reproduction of developed CBL over comparatively short fetches. The bottom heating is controlled to produce the constant heat flux through the floor of the test section. The flow velocity components in the tunnel are measured with a laser Doppler system; for temperature measurements, the resistance-wire technique is employed.A quasi-stationary, horizontally evolving CBL was reproduced in the tunnel, with convective Richardson numbers RiT and RiN up to 10 and 20, respectively, and the shear/buoyancy dynamic ratio u(/w( in the range of 0.2-0.5. Within the employed modeling approach, means and other statistics of the flow were calculated by temporal averaging. Deardorff mixed-layer scaling was used as a framework for processing and interpreting the experimental results. The comparison of the wind tunnel data with results of atmospheric, water tank, and numerical studies of the CBL shows the crucial dependence of the turbulence statistics in the upper part of the layer on the parameters of entrainment, as well as the modification of the CBL turbulence regime by the surface shear.
Heating facilities: Klamath Lutheran Church, Klamath Falls, Oregon
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1980-08-01
The Klamath Lutheran Church is a masonry structure with cathedral ceiling containing approximately 5800 sq ft of floor area. This building is currently heated by two duct furnaces and a unit heater all of which are gas fired. An Educational Wing of approximately 6300 sq ft was added in 1958. This building, containing 2 assembly rooms and a number of classrooms is of uninsulated frame construction, with extensive glass area. A gas-fired boiler supplying finned tube radiators currently heats this wing. Four specific options for displacing all or part of the heating duty with geothermal were examined. These options are:more » case 1 - drilling a production and injection well on the property and using the resultant hot water (180/sup 0/F) to heat the entire facility; case 3 - using effluent from the Klamath Union High School to heat the entire facility; no well drilling required; case 2 - using effluent from the Klamath Union High School to heat only the church building; the present gas boiler would heat the Educational Wing; and case 4 - drilling a production and injection well on the property and using the resulting water (70/sup 0/F) to supply a water-to-water heat pump. Of the four cases examined, case 3 (heating of both the church building and educational wing with effluent from the Klamath Union High School) seems to offer the greatest potential and earliest simple payback period. (MHR)« less
Li, Junyou
2017-01-01
Antibiotics have long been of great benefit for people, both in the medical treatment of human disease and in animal food where they improve the growth performance and feed utilization during animal production. Antibiotics as in-feed supplements affect all stages of pork production, including the gestation, nursing, growing, and finishing stages, although the effects show stage-dependent differences. However, the use of antibiotics in animal feed has become a worldwide concern. This review describes why sub-therapeutic levels of antibiotic additives in animal feed have become an integral part of animal feeding programs for more than 70 years, particularly in pork production. It also discusses the threat of the long-term use of sub-therapeutic levels of antibiotics in pork production. In recent years, the effectiveness of in-feed antibiotics has tended to decrease. This review analyzes this change from various perspectives. First, the equipment used at pig farms has improved dramatically and is more sanitary. Worldwide, more pig farms use pig farrowing crates, gestation crates, piglet nursery crates, flooring devices, piggery ventilation and cooler systems, automatic pig feeders, piggery heating equipment, and artificial insemination systems. In addition, scientists have replaced the use of antibiotics with organic acids, fermented mash, probiotics, prebiotics, minerals, oligosaccharides, enzymes, herbs/flavors, and protein/amino acids, and have improved management and husbandry techniques. In addition, animal welfare legislation has been aimed at improving the quality of the floors and living space, ensuring that animals have permanent access to fresh water, and setting a minimum weaning age. Finally, the prospects and the possibility of replacing antibiotics in pork production are described, in line with recent research results. PMID:28823126
Alshami, Iyad Husni; Sahibuddin, Shamsul; Firdaus, Firdaus
2017-01-01
The Global Positioning System demonstrates the significance of Location Based Services but it cannot be used indoors due to the lack of line of sight between satellites and receivers. Indoor Positioning Systems are needed to provide indoor Location Based Services. Wireless LAN fingerprints are one of the best choices for Indoor Positioning Systems because of their low cost, and high accuracy, however they have many drawbacks: creating radio maps is time consuming, the radio maps will become outdated with any environmental change, different mobile devices read the received signal strength (RSS) differently, and peoples’ presence in LOS between access points and mobile device affects the RSS. This research proposes a new Adaptive Indoor Positioning System model (called DIPS) based on: a dynamic radio map generator, RSS certainty technique and peoples’ presence effect integration for dynamic and multi-floor environments. Dynamic in our context refers to the effects of people and device heterogeneity. DIPS can achieve 98% and 92% positioning accuracy for floor and room positioning, and it achieves 1.2 m for point positioning error. RSS certainty enhanced the positioning accuracy for floor and room for different mobile devices by 11% and 9%. Then by considering the peoples’ presence effect, the error is reduced by 0.2 m. In comparison with other works, DIPS achieves better positioning without extra devices. PMID:28783047
NASA Astrophysics Data System (ADS)
Cao, Liang; Liu, Jiepeng; Li, Jiang; Zhang, Ruizhi
2018-04-01
An extensive experimental and theoretical research study was undertaken to study the vibration serviceability of a long-span prestressed concrete floor system to be used in the lounge of a major airport. Specifically, jumping impact tests were carried out to obtain the floor's modal parameters, followed by an analysis of the distribution of peak accelerations. Running tests were also performed to capture the acceleration responses. The prestressed concrete floor was found to have a low fundamental natural frequency (≈ 8.86 Hz) corresponding to the average modal damping ratio of ≈ 2.17%. A coefficients β rp is proposed for convenient calculation of the maximum root-mean-square acceleration for running. In the theoretical analysis, the prestressed concrete floor under running excitation is treated as a two-span continuous anisotropic rectangular plate with simply-supported edges. The calculated analytical results (natural frequencies and root-mean-square acceleration) agree well with the experimental ones. The analytical approach is thus validated.
2014-04-03
CAPE CANAVERAL, Fla. – The Mobile Launcher is visible through a window inside Firing Room 4 in the Launch Control Center at NASA's Kennedy Space Center in Florida. The Ground Systems Development and Operations Program is overseeing efforts to create a new multi-user firing room in Firing Room 4. The main floor consoles, cabling and wires below the floor and ceiling tiles above have been removed. Sub-flooring has been installed and the room is marked off to create four separate rooms on the main floor. The design of Firing Room 4 will incorporate five control room areas that are flexible to meet current and future NASA and commercial user requirements. The equipment and most of the consoles from Firing Room 4 were moved to Firing Room 2 for possible future reuse. Photo credit: NASA/Ben Smegelsky
USDA-ARS?s Scientific Manuscript database
Binucleate Rhizoctonia fungi cause web blight on azaleas and other woody ornamental plants. This research focused on one aspect of how the pathogen may spread from contaminated floors of propagation houses into trays containing clean azalea stem cuttings that generate new root systems. Rhizoctonia w...
Forest Floor CO2 Flux From Two Contrasting Ecosystems in the Southern Appalachians
James M. Vose; Barton D. Clinton; Verl Emrick
1995-01-01
We measured forest floor CO2 flux in two contrasting ecosystems (white pine plantation and northern hardwood ecosystems at low and high elevations, respectively) in May and September 1993 to quantify differences and determine factors regulating CO2 fluxes. An automated IRGA based, flow through system was used with chambers...
General view of the shop floor looking north in the ...
General view of the shop floor looking north in the Vertical Processing Area of the Space Shuttle Main Engine (SSME) Processing Facility at Kennedy Space Center. SSME number 2061 is in the foreground. - Space Transportation System, Space Shuttle Main Engine, Lyndon B. Johnson Space Center, 2101 NASA Parkway, Houston, Harris County, TX
30. View of mezzanine floor level in transmitter building no. ...
30. View of mezzanine floor level in transmitter building no. 102 showing control transmitter electronic cabinets and control modules. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK
Floor Plans Engine Removal Platform, Hold Down Arm Platform, ...
Floor Plans - Engine Removal Platform, Hold Down Arm Platform, Hydraulic Equipment Platforms, Isometric Cutaway of Engine Removal Platform, Isometric Cutaway of Hold Down Arm Platform, Isometric Cutaway of Hydraulic Platforms and Engine Support System Access - Marshall Space Flight Center, Saturn V S-IC Static Test Facility, West Test Area, Huntsville, Madison County, AL
ETR BUILDING, TRA642, INTERIOR. CONSOLE FLOOR, SOUTH HALF. SOUTH SIDE ...
ETR BUILDING, TRA-642, INTERIOR. CONSOLE FLOOR, SOUTH HALF. SOUTH SIDE OF ETR REACTOR, CAMERA FACING NORTH. CABINET CONTAINING "NUCLEAR INSTRUMENT SYSTEMS" IS RESTRICTED. INL NEGATIVE NO. HD46-18-4. Mike Crane, Photographer, 2/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
30. SECOND FLOOR EAST SIDE APARTMENT WEST BEDROOM INTERIOR SHOWING ...
30. SECOND FLOOR EAST SIDE APARTMENT WEST BEDROOM INTERIOR SHOWING PAIRED 6-LIGHT OVER 6-LIGHT DOUBLE-HUNG, WOOD-FRAME WINDOWS THROUGH NORTH WALL. ORIGINAL LOUVERED DOORS FRAME CLOSET AT PHOTO LEFT. VIEW TO NORTH. - Lee Vining Creek Hydroelectric System, Triplex Cottage, Lee Vining Creek, Lee Vining, Mono County, CA
9. EXTERIOR OF ENCLOSED PORTION OF SECOND FLOOR WEST SIDE ...
9. EXTERIOR OF ENCLOSED PORTION OF SECOND FLOOR WEST SIDE APARTMENT ENTRYWAY SHOWING STAIR LANDING AND OPEN FRONT DOOR FLANKED BY PAIRED 4-LIGHT OVER 4-LIGHT DOUBLE-HUNG, WOOD-FRAME WINDOWS. VIEW TO NORTHEAST. - Lee Vining Creek Hydroelectric System, Triplex Cottage, Lee Vining Creek, Lee Vining, Mono County, CA
20. FIRST FLOOR APARTMENT NORTH BEDROOM INTERIOR LOOKING THROUGH DOOR ...
20. FIRST FLOOR APARTMENT NORTH BEDROOM INTERIOR LOOKING THROUGH DOOR FROM LIVING ROOM. GROUP OF THREE 6-LIGHT OVER 6-LIGHT DOUBLE-HUNG, WOOD-FRAME WINDOWS AT PHOTO CENTER THROUGH NORTH (FRONT) WALL OF HOUSE. VIEW TO EAST. - Lee Vining Creek Hydroelectric System, Triplex Cottage, Lee Vining Creek, Lee Vining, Mono County, CA
Al-Rubaye, Adnan A K; Ekesi, Nnamdi S; Zaki, Sura; Emami, Nima K; Wideman, Robert F; Rhoads, Douglas D
2017-02-01
Lameness in broiler chickens is a significant animal welfare and financial issue. Bacterial chondronecrosis with osteomyelitis (BCO) leading to lameness can be enhanced by rearing young broilers on wire flooring. Using the wire floor system, we identified Staphylococcus agnetis as the predominant isolate in BCO of the proximal tibiae and femora, and blood of lame broilers. Administration of S. agnetis isolates in water can induce lameness. We now report that the wire floor system increases bacterial translocation into the blood stream. We have also determined that approximately 10 5 CFU/mL is the minimum effective dose in the drinking water and that challenge at 10, 20, or 30 days of age produces similar incidences of lameness. BCO isolates of S. agnetis are much more effective than other Staphylococcus species and can overwhelm the protective effects of some commercial probiotics. Finally, we also demonstrated that the BCO lameness induced by administration of S. agnetis in the drinking water is transmissible to unchallenged broilers in the same pen. © 2016 Poultry Science Association Inc.
Spring tube braces for seismic isolation of buildings
NASA Astrophysics Data System (ADS)
Karayel, V.; Yuksel, Ercan; Gokce, T.; Sahin, F.
2017-01-01
A new low-cost seismic isolation system based on spring tube bracings has been proposed and studied at the Structural and Earthquake Engineering Laboratory of Istanbul Technical University. Multiple compression-type springs are positioned in a special cylindrical tube to obtain a symmetrical response in tension and compression-type axial loading. An isolation floor, which consists of pin-ended steel columns and spring tube bracings, is constructed at the foundation level or any intermediate level of the building. An experimental campaign with three stages was completed to evaluate the capability of the system. First, the behavior of the spring tubes subjected to axial displacement reversals with varying frequencies was determined. In the second phase, the isolation floor was assessed in the quasi-static tests. Finally, a ¼ scaled 3D steel frame was tested on the shake table using actual acceleration records. The transmitted acceleration to the floor levels is greatly diminished because of the isolation story, which effects longer period and higher damping. There are no stability and self-centering problems in the isolation floor.
Near-field entrainment in black smoker plumes
NASA Astrophysics Data System (ADS)
Smith, J. E.; Germanovich, L. N.; Lowell, R. P.
2013-12-01
In this work, we study the entrainment rate of the ambient fluid into a plume in the extreme conditions of hydrothermal venting at ocean floor depths that would be difficult to reproduce in the laboratory. Specifically, we investigate the flow regime in the lower parts of three black smoker plumes in the Main Endeavour Field on the Juan de Fuca Ridge discharging at temperatures of 249°C, 333°C, and 336°C and a pressure of 21 MPa. Such flow conditions are typical for ocean floor hydrothermal venting but would be difficult to reproduce in the laboratory. The centerline temperature was measured at several heights in the plume above the orifice. Using a previously developed turbine flow meter, we also measured the mean flow velocity at the orifice. Measurements were conducted during dives 4452 and 4518 on the submersible Alvin. Using these measurements, we obtained a range of 0.064 - 0.068 for values of the entrainment coefficient α, which is assumed constant near the orifice. This is half the value of α ≈ 0.12 - 0.13 that would be expected for plume flow regimes based on the existing laboratory results and field measurements in lower temperature and pressure conditions. In fact, α = 0.064 - 0.068 is even smaller than the value of α ≈ 0.075 characteristic of jet flow regimes and appears to be the lowest reported in the literature. Assuming that the mean value α = 0.066 is typical for hydrothermal venting at ocean floor depths, we then characterized the flow regimes of 63 black smoker plumes located on the Endeavor Segment of the Juan de Fuca Ridge. Work with the obtained data is ongoing, but current results indicate that approximately half of these black smokers are lazy in the sense that their plumes exhibit momentum deficits compared to the pure plume flow that develops as the plume rises. The remaining half produces forced plumes that show the momentum excess compared to the pure plumes. The lower value of the entrainment coefficient has important implications for measurements of mass and heat output at mid-oceanic ridges. For example, determining heat output based on the maximum height of plume rise has become a common method of measuring heat flux produced by hydrothermal circulation at mid-oceanic ridges. The fundamental theory for the rise and spreading of turbulent buoyant plumes suggests that the heat output in this method is proportional to α2 and is, therefore, sensitive to the value of α. The considerably different entrainment rates in lazy and forced black smoker plumes may be important for understanding larvae transport mechanism in the life cycle of macrofauna near hydrothermal vents.
Predictions of VRF on a Langmuir Probe under the RF Heating Spiral on the Divertor Floor on NSTX-U
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hosea, J C; Perkins, R J; Jaworski, M A
RF heating deposition spirals are observed on the divertor plates on NSTX as shown in for a NB plus RF heating case. It has been shown that the RF spiral is tracked quite well by the spiral mapping of the strike points on the divertor plate of magnetic field lines passing in front of the high harmonic fast wave (HHFW) antenna on NSTX. Indeed, both current instrumented tiles and Langmuir probes respond to the spiral when it is positioned over them. In particular, a positive increment in tile current (collection of electrons) is obtained when the spiral is over themore » tile. This current can be due to RF rectification and/or RF heating of the scrape off layer (SOL) plasma along the magnetic field lines passing in front of the the HHFW antenna. It is important to determine quantitatively the relative contributions of these processes. Here we explore the properties of the characteristics of probes on the lower divertor plate to determine the likelyhood that the primary cause of the RF heat deposition is RF rectification.« less
How to define pathologic pelvic floor descent in MR defecography during defecation?
Schawkat, Khoschy; Heinrich, Henriette; Parker, Helen L; Barth, Borna K; Mathew, Rishi P; Weishaupt, Dominik; Fox, Mark; Reiner, Caecilia S
2018-06-01
To assess the extents of pelvic floor descent both during the maximal straining phase and the defecation phase in healthy volunteers and in patients with pelvic floor disorders, studied with MR defecography (MRD), and to define specific threshold values for pelvic floor descent during the defecation phase. Twenty-two patients (mean age 51 ± 19.4) with obstructed defecation and 20 healthy volunteers (mean age 33.4 ± 11.5) underwent 3.0T MRD in supine position using midsagittal T2-weighted images. Two radiologists performed measurements in reference to PCL-lines in straining and during defecation. In order to identify cutoff values of pelvic floor measurements for diagnosis of pathologic pelvic floor descent [anterior, middle, and posterior compartments (AC, MC, PC)], receiver-operating characteristic (ROC) curves were plotted. Pelvic floor descent of all three compartments was significantly larger during defecation than at straining in patients and healthy volunteers (p < 0.002). When grading pelvic floor descent in the straining phase, only two healthy volunteers showed moderate PC descent (10%), which is considered pathologic. However, when applying the grading system during defecation, PC descent was overestimated with 50% of the healthy volunteers (10 of 20) showing moderate PC descent. The AUC for PC measurements during defecation was 0.77 (p = 0.003) and suggests a cutoff value of 45 mm below the PCL to identify patients with pathologic PC descent. With the adapted cutoff, only 15% of healthy volunteers show pathologic PC descent during defecation. MRD measurements during straining and defecation can be used to differentiate patients with pelvic floor dysfunction from healthy volunteers. However, different cutoff values should be used during straining and during defecation to define normal or pathologic PC descent.
NASA Technical Reports Server (NTRS)
Zhou, Yuyu; Weng, Qihao; Gurney, Kevin R.; Shuai, Yanmin; Hu, Xuefei
2012-01-01
This paper examined the relationship between remotely sensed anthropogenic heat discharge and energy use from residential and commercial buildings across multiple scales in the city of Indianapolis, Indiana, USA. The anthropogenic heat discharge was estimated with a remote sensing-based surface energy balance model, which was parameterized using land cover, land surface temperature, albedo, and meteorological data. The building energy use was estimated using a GIS-based building energy simulation model in conjunction with Department of Energy/Energy Information Administration survey data, the Assessor's parcel data, GIS floor areas data, and remote sensing-derived building height data. The spatial patterns of anthropogenic heat discharge and energy use from residential and commercial buildings were analyzed and compared. Quantitative relationships were evaluated across multiple scales from pixel aggregation to census block. The results indicate that anthropogenic heat discharge is consistent with building energy use in terms of the spatial pattern, and that building energy use accounts for a significant fraction of anthropogenic heat discharge. The research also implies that the relationship between anthropogenic heat discharge and building energy use is scale-dependent. The simultaneous estimation of anthropogenic heat discharge and building energy use via two independent methods improves the understanding of the surface energy balance in an urban landscape. The anthropogenic heat discharge derived from remote sensing and meteorological data may be able to serve as a spatial distribution proxy for spatially-resolved building energy use, and even for fossil-fuel CO2 emissions if additional factors are considered.
Error floor behavior study of LDPC codes for concatenated codes design
NASA Astrophysics Data System (ADS)
Chen, Weigang; Yin, Liuguo; Lu, Jianhua
2007-11-01
Error floor behavior of low-density parity-check (LDPC) codes using quantized decoding algorithms is statistically studied with experimental results on a hardware evaluation platform. The results present the distribution of the residual errors after decoding failure and reveal that the number of residual error bits in a codeword is usually very small using quantized sum-product (SP) algorithm. Therefore, LDPC code may serve as the inner code in a concatenated coding system with a high code rate outer code and thus an ultra low error floor can be achieved. This conclusion is also verified by the experimental results.
Processing of SeaMARC swath sonar imagery
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pratson, L.; Malinverno, A.; Edwards, M.
1990-05-01
Side-scan swath sonar systems have become an increasingly important means of mapping the sea floor. Two such systems are the deep-towed, high-resolution SeaMARC I sonar, which has a variable swath width of up to 5 km, and the shallow-towed, lower-resolution SeaMARC II sonar, which has a swath width of 10 km. The sea-floor imagery of acoustic backscatter output by the SeaMARC sonars is analogous to aerial photographs and airborne side-looking radar images of continental topography. Geologic interpretation of the sea-floor imagery is greatly facilitated by image processing. Image processing of the digital backscatter data involves removal of noise by medianmore » filtering, spatial filtering to remove sonar scans of anomalous intensity, across-track corrections to remove beam patterns caused by nonuniform response of the sonar transducers to changes in incident angle, and contrast enhancement by histogram equalization to maximize the available dynamic range. Correct geologic interpretation requires submarine structural fabrics to be displayed in their proper locations and orientations. Geographic projection of sea-floor imagery is achieved by merging the enhanced imagery with the sonar vehicle navigation and correcting for vehicle attitude. Co-registration of bathymetry with sonar imagery introduces sea-floor relief and permits the imagery to be displayed in three-dimensional perspectives, furthering the ability of the marine geologist to infer the processes shaping formerly hidden subsea terrains.« less
1989-12-22
and Floor Space Utilization for the Arc Weld and Heat Treat Shop," proposes that a bridge crane be installed in this area to move large heavy parts...levels. It is difficult to quantify the effects of this environment, but they certainly include increased stress and lowered productivity. 8.1.1.3...team study, under the QP4 program. While MABPSA makes some use of powered material handling equipment (forklift trucks and overhead cranes ) most
DOE Office of Scientific and Technical Information (OSTI.GOV)
none,
2015-09-01
Case study of two DOE 2015 Housing Innovation Award winning custom homes in the marine climate that got HERS 39 and 38 without PV or HERS 2-12 and -9 with PV, with 6.5” SIP walls and 10.25” SIP roof; 11.75 ICF around slab, R-20 rigid foam under slab; radiant floor heat and passive design; air-to-water heatpump, fresh air intake with fan, triple-pane windows, 100% LED.
Polymeric compositions incorporating polyethylene glycol as a phase change material
Salyer, Ival O.; Griffen, Charles W.
1989-01-01
A polymeric composition comprising a polymeric material and polyethylene glycol or end-capped polyethylene glycol as a phase change material, said polyethylene glycol and said end-capped polyethylene glycol having a molecular weight greater than about 400 and a heat of fusion greater than about 30 cal/g; the composition is useful in making molded and/or coated materials such as flooring, tiles, wall panels and the like; paints containing polyethylene glycols or end-capped polyethylene glycols are also disclosed.
Preventing spontaneous combustion after mine closing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lewicki, G.
1987-11-01
The author explains how the Northern Coal Company and a Houston-based firefighting firm developed an innovative technique to reduce the risk of spontaneous combustion after mine closing in its Rienau number2 Mine. The ''Light Water TM'' ATC series of firefighting foam concentrates were designed for extinguishing flammable liquid fires. By slightly altering the chemicals, the concentrates could be used to seal the coal ribs, floor, and roof, reducing the risk of combustion. Subsequent monitoring of the mine has identified no signs of heating.
NASA Technical Reports Server (NTRS)
Shields, N. L., Jr.; Martin, M. F.; Paulukaitis, K. R.; Haslam, J. W., Jr.; Henderson, D. E.
1986-01-01
The teleoperator and Robotics Evaluation Facility (TOREF) is composed of a 4,000 square foot precision air bearing floor, the Teleoperator Motion Base, the Target Motion and Support Simulator, the mock-ups of the Hubble Space Telescope, Multi-mission Modular Spacecraft, and the Orbital Maneuvering Vehicle (OMV). The TOREF and its general capabilities to support the OMV and other remote system simulations; the facility operating procedures and requirements; and the results of generic OMV investigations are summarized.
92. View of transmitter building no. 102 first floor coolant ...
92. View of transmitter building no. 102 first floor coolant process water tanks (sodium bisulfate solution), stainless steel, for electronic systems cooling in transmitter and MIP rooms. RCA Services Company 29 September, 1960, official photograph BMEWS Project by unknown photograph, Photographic Services, Riverton, NJ, BMEWS, clear as negative no. A-1226 - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK
Frequency-noise cancellation in semiconductor lasers by nonlinear heterodyne detection.
Bondurant, R S; Welford, D; Alexander, S B; Chan, V W
1986-12-01
The bit-error-rate (BER) performance of conventional noncoherent, heterodyne frequency-shift-keyed (FSK) optical communications systems can be surpassed by the use of a differential FSK modulation format and nonlinear postdetection processing at the receiver. A BER floor exists for conventional frequency-shift keying because of the frequency noise of the transmitter and local oscillator. The use of differential frequency-shift keying with nonlinear postdetection processing suppresses this BER floor for the semiconductor laser system considered here.
Method to prevent/mitigate steam explosions in casting pits
Taleyarkhan, Rusi P.
1996-01-01
Steam explosions can be prevented or mitigated during a metal casting process by the placement of a perforated flooring system in the casting pit. An upward flow of compressed gas through this perforated flooring system is introduced during the casting process to produce a buffer layer between any spilled molten metal and the cooling water in the reservoir. This buffer layer provides a hydrodynamic layer which acts to prevent or mitigate steam explosions resulting from hot, molten metal being spilled into or onto the cooling water.
Modeling of fire smoke movement in multizone garments building using two open source platforms
NASA Astrophysics Data System (ADS)
Khandoker, Md. Arifur Rahman; Galib, Musanna; Islam, Adnan; Rahman, Md. Ashiqur
2017-06-01
Casualty of garment factory workers from factory fire in Bangladesh is a recurring tragedy. Smoke, which is more fatal than fire itself, often propagates through different pathways from lower to upper floors during building fire. Among the toxic gases produced from a building fire, carbon monoxide (CO) can be deadly, even in small amounts. This paper models the propagation and transportation of fire induced smoke (CO) that resulted from the burning of synthetic polyester fibers using two open source platforms, CONTAM and Fire Dynamics Simulator (FDS). Smoke migration in a generic multistoried garment factory building in Bangladesh is modeled using CONTAM where each floor is compartmentalized by different zones. The elevator and stairway shafts are modeled by phantom zones to simulate contaminant (CO) transport from one floor to upper floors. FDS analysis involves burning of two different stacks of polyester jacket of six feet height and with a maximum heat release rate per unit area of 1500kw/m2 over a storage area 50m2 and 150m2, respectively. The resulting CO generation and removal rates from FDS are used in CONTAM to predict fire-borne CO propagation in different zones of the garment building. Findings of the study exhibit that the contaminant flow rate is a strong function of the position of building geometry, location of initiation of fire, amount of burnt material, presence of AHU and contaminant generation and removal rate of CO from the source location etc. The transport of fire-smoke in the building Hallways, stairways and lifts are also investigated in detail to examine the safe egress of the occupants in case of fire.
Kahyaoglu Sut, Hatice; Balkanli Kaplan, Petek
2016-03-01
The aim of this study was to investigate the effects of pelvic floor muscle exercise during pregnancy and the postpartum period on pelvic floor muscle activity and voiding functions. Pregnant women (n = 60) were randomly assigned into two groups (Training [n = 30] and Control [n = 30]) using a computer-based system. Pelvic floor muscle strength was measured using a perineometry device. Urinary symptoms were measured using the Urinary Distress Inventory (UDI-6), Incontinence Impact Questionnaire (IIQ-7), and the Overactive Bladder Questionnaire (OAB-q). Voiding functions were measured using uroflowmetry and 3-day voiding diaries. Measurements were obtained at week 28, weeks 36-38 of pregnancy, and postpartum weeks 6-8. Pelvic floor muscle strength significantly decreased during the pregnancy (P < 0.001). However, pelvic floor muscle strength improvement was significantly higher in the Training group compared to the Control group (P < 0.001). The UDI-6, IIQ-7, and OAB-q scores did not significantly change during weeks 36-38 of pregnancy in the Training group (P > 0.05). However, UDI-6, coping, concern, and total scores of OAB-q were significantly decreased during weeks 36-38 of pregnancy in the Control group (P < 0.05). The UDI-6 and OAB-q scores were significantly improved during postpartum weeks 6-8 (P < 0.05). Voiding functions were negatively affected in both groups, decreasing during weeks 36-38 of pregnancy and improving during the postpartum period. Pregnancy and delivery affect pelvic floor muscle strength, urinary symptoms, quality of life, and voiding functions. Pelvic floor muscle exercises applied during pregnancy and the postpartum period increase pelvic floor muscle strength and prevent deterioration of urinary symptoms and quality of life in pregnancy. © 2015 Wiley Periodicals, Inc.
Özengin, Nuriye; Ün Yıldırım, Necmiye; Duran, Bülent
2015-03-01
This study aimed to compare the effectiveness of stabilization exercises and pelvic floor muscle training in women with stage 1 and 2 pelvic organ prolapse. In a total 38 women with pelvic organ prolapse whose average age was 45.60 years, pelvic floor muscles were evaluated with electromyography, and prolapse with pelvic organ prolapse quantification system, and the quality of life with prolapse quality of life questionnaire. Afterwards, the subjects were divided into two groups; stabilization exercise group (n=19) and pelvic floor muscle training group (n=19). Stabilization exercise group were given training for 8 weeks, 3 times a week. Pelvic floor muscle training group were given eight-week home exercises. Each group was assessed before training and after eight weeks. An increase was found in the pelvic muscle activation response in the 2 groups (p≤0.05). There was no difference in EMG activity values between the groups (p>0.05). A difference was found in the values Aa, Ba and C in subjects of each group (p≤0.05), and the TVL, Ap, Bp and D values of subjects in pelvic floor muscle training group (p≤0.05) in the before and after pelvic organ prolapse quantification system assessment, however, no difference was found between the groups (p≤0.05). A positive difference was found in the effect of prolapse sub parameter in each of the two groups, and in general health perception sub parameter in subjects of stabilization exercise group (p<0.05) in the prolapse quality of life questionnaire. It was concluded that both training programs increased the pelvic floor muscle strength, provided a decline in prolapse stages. Stabilization exercise has increased general health perception unlike home training, thus, these exercises can be added to the treatment of women with prolapse.
Özengin, Nuriye; Ün Yıldırım, Necmiye; Duran, Bülent
2015-01-01
Objective: This study aimed to compare the effectiveness of stabilization exercises and pelvic floor muscle training in women with stage 1 and 2 pelvic organ prolapse. Materials and Methods: In a total 38 women with pelvic organ prolapse whose average age was 45.60 years, pelvic floor muscles were evaluated with electromyography, and prolapse with pelvic organ prolapse quantification system, and the quality of life with prolapse quality of life questionnaire. Afterwards, the subjects were divided into two groups; stabilization exercise group (n=19) and pelvic floor muscle training group (n=19). Stabilization exercise group were given training for 8 weeks, 3 times a week. Pelvic floor muscle training group were given eight-week home exercises. Each group was assessed before training and after eight weeks. Results: An increase was found in the pelvic muscle activation response in the 2 groups (p≤0.05). There was no difference in EMG activity values between the groups (p>0.05). A difference was found in the values Aa, Ba and C in subjects of each group (p≤0.05), and the TVL, Ap, Bp and D values of subjects in pelvic floor muscle training group (p≤0.05) in the before and after pelvic organ prolapse quantification system assessment, however, no difference was found between the groups (p≤0.05). A positive difference was found in the effect of prolapse sub parameter in each of the two groups, and in general health perception sub parameter in subjects of stabilization exercise group (p<0.05) in the prolapse quality of life questionnaire. Conclusions: It was concluded that both training programs increased the pelvic floor muscle strength, provided a decline in prolapse stages. Stabilization exercise has increased general health perception unlike home training, thus, these exercises can be added to the treatment of women with prolapse. PMID:28913034
Overview of the Westinghouse Small Modular Reactor building layout
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cronje, J. M.; Van Wyk, J. J.; Memmott, M. J.
The Westinghouse Small Modular Reactor (SMR) is an 800 MWt (>225 MWe) integral pressurized water reactor (iPWR), in which all of the components typically associated with the nuclear steam supply system (NSSS) of a nuclear power plant are incorporated within a single reactor pressure vessel. This paper is the third in a series of four papers, which describe the design and functionality of the Westinghouse SMR. It focuses in particular upon the plant building layout and modular design of the Westinghouse SMR. In the development of small modular reactors, the building layout is an area where the safety of themore » plant can be improved by applying new design approaches. This paper will present an overview of the Westinghouse SMR building layout and indicate how the design features improve the safety and robustness of the plant. The Westinghouse SMR is designed with no shared systems between individual reactor units. The main buildings inside the security fence are the nuclear island, the rad-waste building, the annex building, and the turbine building. All safety related equipment is located in the nuclear island, which is a seismic class 1 building. To further enhance the safety and robustness of the design, the reactor, containment, and most of the safety related equipment are located below grade on the nuclear island. This reduces the possibility of severe damage from external threats or natural disasters. Two safety related ultimate heat sink (UHS) water tanks that are used for decay heat removal are located above grade, but are redundant and physically separated as far as possible for improved safety. The reactor and containment vessel are located below grade in the center of the nuclear island. The rad-waste and other radioactive systems are located on the bottom floors to limit the radiation exposure to personnel. The Westinghouse SMR safety trains are completely separated into four unconnected quadrants of the building, with access between quadrants only allowed above grade. This is an improvement to conventional reactor design since it prevents failures of multiple trains during floods or fires and other external events. The main control room is located below grade, with a remote shutdown room in a different quadrant. All defense in depth systems are placed on the nuclear island, primarily above grade, while the safety systems are located on lower floors. The economics of the Westinghouse SMR challenges the established approach of large Light Water Reactors (LWR) that utilized the economies of scale to reach economic competitiveness. To serve the market expectation of smaller capital investment and cost competitive energy, a modular design approach is implemented within the Westinghouse SMR. The Westinghouse SMR building layout integrates the three basic design constraints of modularization; transportation, handling and module-joining technology. (authors)« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ohata, Tetsuo; Furukawa, Teruo; Higuchi, Keiji
1994-08-01
Perennial cave ice in a cave located at Mt. Fuji in central Japan was studied to investigate the basic characteristics and the cause for existence of such ice under warm ground-level climate considering the ice cave as a thermal and hydrological system. Fuji Ice Cave is a lava tube cave 150 m in length with a collapsed part at the entrance. Measurements from 1984 to 1986 showed that the surface-level change of floor ice occurred due to freezing and melting at the surface and that melting at the bottom of the ice was negligible. The annual amplitude of change inmore » surface level was larger near the entrance. Meterological data showed that the cold air inflow to the cave was strong in winter, but in summer the cave was maintained near 0[degrees]C with only weak inflow of warm air. The predominant wind system was from the entrance to the interior in both winter and summer, but the spatial scale of the wind system was different. Heat budget consideration of the cave showed that the largest component was the strong inflow of subzero dry air mass in winter. Cooling in winter was compensated for by summer inflow of warm air, heat transport from the surrounding ground layer, and loss of sensible heat due to cooling of the cave for the observed year. Strong inflow of cold air and weak inflow of warm air, which is extremely low compared to the ground level air, seemed to be the most important condition. Thus the thermal condition of the cave is quasi-balanced at the presence condition below 0[degrees]C with ice. It can be said that the interrelated result of the climatological and special structural conditions makes this cave very cold, and allows perennial ice to exist in the cave. Other climatological factors such as precipitation seem to be minor factors. 17 refs., 3 figs., 3 tabs.« less
Can deformation of a polymer film with a rigid coating model geophysical processes?
NASA Astrophysics Data System (ADS)
Volynskii, A. L.; Bazhenov, S. L.
2007-12-01
The structural and mechanical behavior of polymer films with a thin rigid coating is analyzed. The behavior of such systems under applied stress is accompanied by the formation of a regular wavy surface relief and by regular fragmentation of the coating. The above phenomena are shown to be universal. Both phenomena (stress-induced development of a regular wavy surface relief and regular fragmentation of the coating) are provided by the specific features of mechanical stress transfer from a compliant soft support to a rigid thin coating. The above phenomena are associated with a specific structure of the system, which is referred to as “a rigid coating on a soft substratum” system (RCSS). Surface microrelief in RCSS systems is similar to the ocean floor relief in the vicinity of mid-oceanic ridges. Thus, the complex system composed of a young oceanic crust and upper Earth's mantle may be considered as typically “a solid coating on a soft substratum” system. Specific features of the ocean floor relief are analyzed in terms of the approach advanced for the description of the structural mechanical behavior of polymer films with a rigid coating. This analysis allowed to estimate the strength of an ocean floor.
Wan, M P; Chao, C Y H
2007-06-01
Expiratory droplets and droplet nuclei can be pathogen carriers for airborne diseases. Their transport characteristics were studied in detail in two idealized floor-supply-type ventilation flow patterns: Unidirectional-upward and single-side-floor, using a multiphase numerical model. The model was validated by running interferometric Mie imaging experiments using test droplets with nonvolatile content, which formed droplet nuclei, ultimately, in a class-100 clean-room chamber. By comparing the droplet dispersion and removal characteristics with data of two other ceiling-supply ventilation systems collected from a previous work, deviations from the perfectly mixed ventilation condition were found to exist in various cases to different extent. The unidirectional-upward system was found to be more efficient in removing the smallest droplet nuclei (formed from 1.5 mum droplets) by air extraction, but it became less effective for larger droplets and droplet nuclei. Instead, the single-side-floor system was shown to be more favorable in removing these large droplets and droplet nuclei. In the single-side-floor system, the lateral overall dispersion coefficients for the small droplets and nuclei (initial size =45 mum) were about an order of magnitude higher than those in the unidirectional-upward system. It indicated that bulk lateral airflow transport in the single-side-floor system was much stronger than the lateral dispersion mechanism induced mainly by air turbulence in the unidirectional-upward system. The time required for the droplets and droplet nuclei to be transported to the exhaust vent or deposition surfaces for removal varied with different ventilation flow patterns. Possible underestimation of exposure level existed if the perfectly mixed condition was assumed. For example, the weak lateral dispersion in the unidirectional ventilation systems made expiratory droplets and droplet nuclei stay at close distance to the source leading to highly nonuniform spatial distributions. The distance between the source and susceptible patients became an additional concern in exposure analysis. Relative significance of the air-extraction removal mechanism was studied. This can have impact to the performance evaluation of filtration and disinfection systems installed in the indoor environment. These findings revealed the need for further development in a risk-assessment model incorporating the effect of different ventilation systems on distributing expiratory droplets and droplet nuclei nonuniformly in various indoor spaces, such as buildings, aircraft cabins, trains, etc.
21. INTERIOR VIEW, UNDER THE MAIN FLOOR SHOWING THE LINESHAFT ...
21. INTERIOR VIEW, UNDER THE MAIN FLOOR SHOWING THE LINESHAFT SYSTEM ONCE POWERED BY A STEAM ENGINE AND LATER BY TWO LARGE ELECTRICAL MILL MOTORS (NOTICE LARGE GEAR IN FOREGROUND) THAT OPERATED EACH NAIL MACHINE; PRESENTLY THE NAIL MACHINES ARE DRIVEN BY INDIVIDUAL ELECTRICAL MOTORS - LaBelle Iron Works, Thirtieth & Wood Streets, Wheeling, Ohio County, WV
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-01
... publication of the Commission's order approving the proposed Plan in the Federal Register. D. Development and..., Illinois 60605 (5) EDGA Exchange, Inc., 545 Washington Boulevard, Sixth Floor, Jersey City, NJ 07310 (6) EDGX Exchange, Inc., 545 Washington Boulevard, Sixth Floor, Jersey City, NJ 07310 (7) Financial...
Getting Clever with the Sliding Ladder
ERIC Educational Resources Information Center
De, Subhranil
2014-01-01
The familiar system involving a uniform ladder sliding against a vertical wall and a horizontal floor is considered again. The floor is taken to be smooth and the wall to be possibly rough--a situation where no matter how large the static friction coefficient between the ladder and the wall, the ladder cannot lean at rest and must slide down.…
77 FR 15835 - Privacy Act of 1974: Revision of Privacy Act System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-16
... 333 E. Water St., 4th Floor, Elmira, NY 14901. Long Island Branch Office 350 Motor Parkway, Suite 109..., TX 76155. El Paso District Office 211 North Florence St., 2nd Floor Suite 201, El Paso, TX 79901... Center 801 Tom Martin Drive, Suite 120, Birmingham, AL 35211. [[Page 15838
31. SECOND FLOOR WEST SIDE APARTMENT LIVING ROOM INTERIOR SHOWING ...
31. SECOND FLOOR WEST SIDE APARTMENT LIVING ROOM INTERIOR SHOWING PAIRED 4-LIGHT OVER 4-LIGHT DOUBLE-HUNG, WOOD-FRAME WINDOWS FLANKING ENTRY DOOR WITH UNUSUAL 8-LIGHT WINDOW. OPEN DOORWAY TO PHOTO LEFT LEADS TO KITCHEN. VIEW TO WEST. - Lee Vining Creek Hydroelectric System, Triplex Cottage, Lee Vining Creek, Lee Vining, Mono County, CA
DOE Office of Scientific and Technical Information (OSTI.GOV)
Elhajj, N.R.
1999-03-01
Since 1992, the US Department of Housing and Urban Development has sponsored numerous studies to identify, evaluate, and implement innovative structural materials, such as cold-formed steel (CFS), in the residential market. The use of CFS is still very limited, partly because steel is not being effectively integrated into conventional home construction. One of the major barriers to the use of CFS floor joists is the impact it has on placement of large waste drains and ductwork installed in floor systems. This report provides an overview of tests conducted by the NAHB to integrate these systems with CFS. A brief literaturemore » review of relevant work followed by a detailed overview of the experimental and analytical approach are also provided. The report recommends adoption of the research findings in residential and commercial applications.« less
Dynamic assessment of women pelvic floor function by using a fiber Bragg grating sensor system
NASA Astrophysics Data System (ADS)
Ferreira, Luis A.; Araújo, Francisco M.; Mascarenhas, Teresa; Natal Jorge, Renato M.; Fernandes, António A.
2006-02-01
We present a novel sensing system consisting of an intravaginal probe and an optoelectronic measurement unit, which allows an easy, comfortable and quantitative dynamic evaluation of women pelvic floor muscle strength. The sensing probe is based on a silicone cylinder that transduces radial muscle pressure into axial load applied to a fiber Bragg grating strain sensor. The performance of a first sensor probe prototype with temperature referentiation and of the autonomous, portable optoelectronic measurement unit with data logging capabilities and graphical user interface is disclosed. The presented results refer to an ongoing collaboration work between researchers from the Medical, Optoelectronics and Mechanical areas, directed to the development of equipment that can assist in medical practice and help in the research of primary mechanisms responsible for several pelvic floor disorders, in particular urogenital prolapses.
2014-04-03
CAPE CANAVERAL, Fla. – The Ground Systems Development and Operations Program is overseeing efforts to create a new multi-user firing room in Firing Room 4 in the Launch Control Center at NASA's Kennedy Space Center in Florida. The main floor consoles, cabling and wires below the floor and ceiling tiles above have been removed. Sub-flooring has been installed and the room is marked off to create four separate rooms on the main floor. In view along the soffit are space shuttle launch plaques for 21 missions launched from Firing Room 4. The design of Firing Room 4 will incorporate five control room areas that are flexible to meet current and future NASA and commercial user requirements. The equipment and most of the consoles from Firing Room 4 were moved to Firing Room 2 for possible future reuse. Photo credit: NASA/Ben Smegelsky
STS-121: Discovery Pre-Launch Mission Management Team Press Briefing
NASA Technical Reports Server (NTRS)
2006-01-01
The briefing began with Allard Buetel (NASA Public Affairs) introducing Bill Gerstenmaier (Associate Administrator for Space Operations) who provided an update of the Mission Management team meeting. The 3 criteria reviewed by the team were: a) ascent heating; b) ice formation and c) remaining foam still intact. The ascent heating had a safety factor of 5 and posed no concern. Ice formation was not a concern. In order to insure there was no damage to the remaining foam, an 8ft. pipe with a camera attached was used to provide pictures. The boroscope pictures showed there was no damage to the brackets or foam. The inspection went very well and the foam was acceptable and ready to fly. Then the floor was open to questions from the press.
Automated Visual Cognitive Tasks for Recording Neural Activity Using a Floor Projection Maze
Kent, Brendon W.; Yang, Fang-Chi; Burwell, Rebecca D.
2014-01-01
Neuropsychological tasks used in primates to investigate mechanisms of learning and memory are typically visually guided cognitive tasks. We have developed visual cognitive tasks for rats using the Floor Projection Maze1,2 that are optimized for visual abilities of rats permitting stronger comparisons of experimental findings with other species. In order to investigate neural correlates of learning and memory, we have integrated electrophysiological recordings into fully automated cognitive tasks on the Floor Projection Maze1,2. Behavioral software interfaced with an animal tracking system allows monitoring of the animal's behavior with precise control of image presentation and reward contingencies for better trained animals. Integration with an in vivo electrophysiological recording system enables examination of behavioral correlates of neural activity at selected epochs of a given cognitive task. We describe protocols for a model system that combines automated visual presentation of information to rodents and intracranial reward with electrophysiological approaches. Our model system offers a sophisticated set of tools as a framework for other cognitive tasks to better isolate and identify specific mechanisms contributing to particular cognitive processes. PMID:24638057
Subseabed storage of radioactive waste
NASA Astrophysics Data System (ADS)
Bell, Peter M.
The subject of the storage of nuclear wastes products incites emotional responses from the public, and thus the U.S. Subseabed Disposal Program will have to make a good case for waste storage beneath the ocean floor. The facts attendant, however, describe circumstances necessitating cool-headed analysis to achieve a solution to the growing nuclear waste problem. Emotion aside, a good case indeed is being made for safe disposal beneath the ocean floor.The problems of nuclear waste storage are acute. A year ago, U.S. military weapons production had accumulated over seventy-five million gallons of high-level radioactive liquid waste; solid wastes, such as spent nuclear fuel rods from reactors, amounted to more than 12,000 tons. These wastes are corrosive and will release heat for 1000 years or more. The wastes will remain dangerously radioactive for a period of 10,000 years. There are advantages in storing the wastes on land, in special underground repositories, or on the surface. These include the accessibility to monitor the waste and the possibility of taking action should a container rupture occur, and thus the major efforts to determine suitable disposal at this time are focused on land-based storage. New efforts, not to be confused with ocean dumping practices of the past, are demonstrating that waste containers isolated in the clays and sediments of the ocean floor may be superior (Environ. Sci. Tech., 16, 28A-37A 1982).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paul Higley; J. Robert Woolsey; Ralph Goodman
A Consortium, designed to assemble leaders in gas hydrates research, has been established at the University of Mississippi's Center for Marine Resources and Environmental Technology, CMRET. The primary objective of the group is to design and emplace a remote monitoring station on the sea floor in the northern Gulf of Mexico by the year 2005, in an area where gas hydrates are known to be present at, or just below, the sea floor. This mission necessitates assembling a station that will monitor physical and chemical parameters of the sea water and sea floor sediments on a more-or-less continuous basis overmore » an extended period of time. Development of the station allows for the possibility of expanding its capabilities to include biological monitoring, as a means of assessing environmental health. Establishment of the Consortium has succeeded in fulfilling the critical need to coordinate activities, avoid redundancies and communicate effectively among researchers in this relatively new research arena. Complementary expertise, both scientific and technical, has been assembled to promote innovative research methods and construct necessary instrumentation. Noteworthy achievements one year into the extended life of this cooperative agreement include: (1) Progress on the vertical line array (VLA) of sensors: (1a) Repair attempts of the VLA cable damaged in the October >1000m water depth deployment failed; a new design has been tested successfully. (1b) The acoustic modem damaged in the October deployment was repaired successfully. (1c) Additional acoustic modems with greater depth rating and the appropriate surface communications units have been purchased. (1d) The VLA computer system is being modified for real time communications to the surface vessel using radio telemetry and fiber optic cable. (1e) Positioning sensors--including compass and tilt sensors--were completed and tested. (1f) One of the VLAs has been redesigned to collect near sea floor geochemical data. (2) Progress on the Sea Floor Probe: (2a) With the Consortium's decision to divorce its activities from those of the Joint Industries Program (JIP), due to the JIP's selection of a site in 1300m of water, the Sea Floor Probe (SFP) system was revived as a means to emplace arrays in the shallow subsurface until arrangements can be made for boreholes at >1000m water depth. (2b) The SFP penetrometer has been designed and construction begun. (2c) The SFP geophysical and pore-fluid probes have been designed. (3) Progress on the Acoustic Systems for Monitoring Gas Hydrates: (3a) Video recordings of bubbles emitted from a seep in Mississippi Canyon have been analyzed for effects of currents and temperature changes. (3b) Several acoustic monitoring system concepts have been evaluated for their appropriateness to MC118, i.e., on the deep sea floor. (3c) A mock-up system was built but was rejected as too impractical for deployment on the sea floor. (4) Progress on the Electromagnetic Bubble Detector and Counter: (4a) Laboratory tests were performed using bubbles of different sizes in waters of different salinities to test the sensitivity of the. Differences were detected satisfactorily. (4b) The system was field tested, first at the dock and then at the shallow water test site at Cape Lookout Bight where methane bubbles from the sea floor, naturally, in 10m water depth. The system successfully detected peaks in bubbling as spike decreases in conductivity. (5) Progress on the Mid-Infrared Sensor for Continuous Methane Monitoring: (5a) Modeling and design of an optics platform complementary to the constructed electronics platform for successful incorporation into ''sphereIR'' continues. AutoCAD design and manual construction of mounting pieces for major optical components have been completed. (5b) Initial design concepts for IR-ATR sensor probe geometries have been established and evaluated. Initial evaluations of a horizontal ATR (HATR) sensing probe with fiber optic guiding light have been performed and validate the design concept as a potentially viable deep sea sensing probe. (5c) Ray tracing simulations have been performed to evaluate light propagation through HATR elements to facilitate the optimal design of both the sensing probe and optical configuration of ''sphereIR''. (5d) The highly permeable polymer, polydimethylsiloxane (PDMS), was investigated as a potential methane enrichment membrane for IR-ATR sensors. (6) Progress on the Seismo-acoustic Characterization of Sea Floor Properties and Processes at the Hydrate Monitoring Station: (6a) All system components underwent extensive testing in preparation for determining sea floor acoustic reflection responses at the Gas Hydrate Monitoring Station. (6b) Final testing and commissioning have been completed.« less
Stratification of a closed region containing two buoyancy sources
NASA Astrophysics Data System (ADS)
Thompson, Andrew; Linden, Paul
2005-11-01
Many closed systems such as lakes, ocean basins, rooms etc. have inputs of buoyancy at different levels. We address the question of how the resulting stratification depends on the location of these sources. For example a lake is heated and cooled at the surface, while for a room cool air may be applied at the ceiling but the heat source may be a person standing on the floor. We present an experimental study of convection in a finite box in which we systematically vary the vertical location of two well-separated, constant buoyancy sources. We specifically consider the case of a dense source and a light source so that there is no net buoyancy flux into the tank. We study the development of the large-time stratification in the tank, which falls between one of two limits. When the location of the dense source is significantly higher than the light source, the fluid is well mixed and the system remains largely unstratified. When the location of the light source is significantly higher than the dense source, a two- layer stratification develops. We find that the circulation pattern is dominated by counter-flowing shear layers (Wong, Griffiths & Hughes, 2001), whose number and strength are strongly influenced by the buoyancy source locations. The shear layers are the primary means of communication between the plumes and thus play a large role in the resulting stratification. We support our findings with a simple numerical model.
Convection and thermal radiation analytical models applicable to a nuclear waste repository room
DOE Office of Scientific and Technical Information (OSTI.GOV)
Davis, B.W.
1979-01-17
Time-dependent temperature distributions in a deep geologic nuclear waste repository have a direct impact on the physical integrity of the emplaced canisters and on the design of retrievability options. This report (1) identifies the thermodynamic properties and physical parameters of three convection regimes - forced, natural, and mixed; (2) defines the convection correlations applicable to calculating heat flow in a ventilated (forced-air) and in a nonventilated nuclear waste repository room; and (3) delineates a computer code that (a) computes and compares the floor-to-ceiling heat flow by convection and radiation, and (b) determines the nonlinear equivalent conductivity table for a repositorymore » room. (The tables permit the use of the ADINAT code to model surface-to-surface radiation and the TRUMP code to employ two different emissivity properties when modeling radiation exchange between the surface of two different materials.) The analysis shows that thermal radiation dominates heat flow modes in a nuclear waste repository room.« less