Sample records for floor plan sections

  1. 31. Stair Plans / First Floor, Second Floor, Section Stair ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    31. Stair Plans / First Floor, Second Floor, Section Stair Bulkhead, F.S. Tread & Riser (drawing 8) - Whittier State School, Hospital & Receiving Building, 11850 East Whittier Boulevard, Whittier, Los Angeles County, CA

  2. Refrigeration Plant, North Elevation, Second Floor Plan, East Elevation, Ground ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Refrigeration Plant, North Elevation, Second Floor Plan, East Elevation, Ground Floor Plan, Section A-A - Kennecott Copper Corporation, On Copper River & Northwestern Railroad, Kennicott, Valdez-Cordova Census Area, AK

  3. 18. FLOOR PLAN AND SECTION DRAWING OF POWERHOUSE FOUNDATION AND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    18. FLOOR PLAN AND SECTION DRAWING OF POWERHOUSE FOUNDATION AND DRAFT TUBE Power House Plan and Sections, drawing E-965. Prepared by the Washington Water Power Company, December 27, 1922, revised January 5, 1926. - Enloe Dam, Power House, On Similkameen River, Oroville, Okanogan County, WA

  4. One Bedroom Units: Floor Plan, South Elevation (As Built), North ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    One Bedroom Units: Floor Plan, South Elevation (As Built), North Elevation (As Built), Section A-A (As Built), Section AA (Existing) - Aluminum City Terrace, East Hill Drive, New Kensington, Westmoreland County, PA

  5. Ground Floor Plan (Section A) U.S. Veterans Hospital, Jefferson ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Ground Floor Plan (Section A) - U.S. Veterans Hospital, Jefferson Barracks, Spinal Cord Injury Unit and Tuberculosis Neuropsychiatric Building, VA Medical Center, Jefferson Barracks Division 1 Jefferson Barracks Drive, Saint Louis, Independent City, MO

  6. Ground Floor Plan (Section B) U.S. Veterans Hospital, Jefferson ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Ground Floor Plan (Section B) - U.S. Veterans Hospital, Jefferson Barracks, Spinal Cord Injury Unit and Tuberculosis Neuropsychiatric Building, VA Medical Center, Jefferson Barracks Division 1 Jefferson Barracks Drive, Saint Louis, Independent City, MO

  7. First Floor Plan (Section A) U.S. Veterans Hospital, Jefferson ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    First Floor Plan (Section A) - U.S. Veterans Hospital, Jefferson Barracks, Spinal Cord Injury Unit and Tuberculosis Neuropsychiatric Building, VA Medical Center, Jefferson Barracks Division 1 Jefferson Barracks Drive, Saint Louis, Independent City, MO

  8. First Floor Plan (Section B) U.S. Veterans Hospital, Jefferson ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    First Floor Plan (Section B) - U.S. Veterans Hospital, Jefferson Barracks, Spinal Cord Injury Unit and Tuberculosis Neuropsychiatric Building, VA Medical Center, Jefferson Barracks Division 1 Jefferson Barracks Drive, Saint Louis, Independent City, MO

  9. Second Floor Plan (Section A) U.S. Veterans Hospital, Jefferson ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Second Floor Plan (Section A) - U.S. Veterans Hospital, Jefferson Barracks, Spinal Cord Injury Unit and Tuberculosis Neuropsychiatric Building, VA Medical Center, Jefferson Barracks Division 1 Jefferson Barracks Drive, Saint Louis, Independent City, MO

  10. Second Floor Plan (Section B) U.S. Veterans Hospital, Jefferson ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Second Floor Plan (Section B) - U.S. Veterans Hospital, Jefferson Barracks, Spinal Cord Injury Unit and Tuberculosis Neuropsychiatric Building, VA Medical Center, Jefferson Barracks Division 1 Jefferson Barracks Drive, Saint Louis, Independent City, MO

  11. SECTION BB, FLOOR PLAN Dyess Air Force Base, Atlas ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    SECTION B-B, FLOOR PLAN - Dyess Air Force Base, Atlas F Missle Site S-8, Launch Facility, Approximately 3 miles east of Winters, 500 feet southwest of Highway 1770, center of complex, Winters, Runnels County, TX

  12. HOT CELL BUILDING, TRA632. FIRST FLOOR FOUNDATION PLAN SHOWS SECTIONALIZED ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    HOT CELL BUILDING, TRA-632. FIRST FLOOR FOUNDATION PLAN SHOWS SECTIONALIZED FLOOR LOADINGS AND CONCRETE SLAB THICKNESSES, A TYPICAL FEATURE OF NUCLEAR ARCHITECTURE. IDAHO OPERATIONS OFFICE MTR-632-IDO-2, 11/1952. INL INDEX NO. 531-0632-62-396-110561, REV. 1. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  13. ETR ELECTRICAL BUILDING, TRA648. FLOOR PLANS FOR FIRST FLOOR AND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    ETR ELECTRICAL BUILDING, TRA-648. FLOOR PLANS FOR FIRST FLOOR AND BASEMENT. SECTIONS. KAISER ETR-5528-MTR-648-A-2, 12/1955. INL INDEX NO. 532-0648-00-486-101402, REV. 6. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  14. 60. FIFTH FLOOR PLAN, SECTIONS AND DETAILS OF 1937 ADDITION ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    60. FIFTH FLOOR PLAN, SECTIONS AND DETAILS OF 1937 ADDITION TO BUILDINGS No. 2 and 4, DATED JUNE 24, 1937: SCHMIDT, GARDEN AND ERICKSON, ARCHITECTS - Underwriters' Laboratories, 207-231 East Ohio Street, Chicago, Cook County, IL

  15. 59. FOURTH FLOOR PLAN, SECTIONS AND DETAILS OF 1937 ADDITION ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    59. FOURTH FLOOR PLAN, SECTIONS AND DETAILS OF 1937 ADDITION TO BUILDINGS NO. 2 and 4, DATED JUNE 24, 1937; SCHMIDT, GARDEN AND ERICKSON, ARCHITECTS - Underwriters' Laboratories, 207-231 East Ohio Street, Chicago, Cook County, IL

  16. 4. FLOOR PLAN AND SECTIONS, ADDITION TO POWER HOUSE. United ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. FLOOR PLAN AND SECTIONS, ADDITION TO POWER HOUSE. United Engineering Company Ltd., Alameda Shipyard. Also includes plot plan at 1 inch to 100 feet. John Hudspeth, architect, foot of Main Street, Alameda, California. Sheet 3. Plan no. 10,548. Scale 1/4 inch and h inch to the foot. April 30, 1945, last revised 6/22/45. pencil on vellum - United Engineering Company Shipyard, Boiler House, 2900 Main Street, Alameda, Alameda County, CA

  17. LPT. Guard House (TAN642). Elevations, floor plan, sections, details. Ralph ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    LPT. Guard House (TAN-642). Elevations, floor plan, sections, details. Ralph M. Parsons 1229-12 ANP/GE-7-642-A-S-H7V-1. November 1956. Approved by INEEL Classification Office for public release. INEEL index code no. 038-0642-00-693-107306 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  18. 41. 'Firing Pier, Second Floor Plan, Section No. 2,' submitted ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    41. 'Firing Pier, Second Floor Plan, Section No. 2,' submitted 29 December 1941 by John Brackett, Consulting Engineer, to Public Works Department, Bureau of Yards & Docks. PW Drawing 3867-46, Y&D Drawing 190841. Scale 1/4' = 1'. - Naval Torpedo Station, Firing Pier, North end of Gould Island in Narragansett Bay, Newport, Newport County, RI

  19. 42. 'Firing Pier, Second Floor Plan, Section No. 3,' submitted ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    42. 'Firing Pier, Second Floor Plan, Section No. 3,' submitted 29 December 1941 by John Brackett, Consulting Engineer, to Public Works Department, Bureau of Yards & Docks. PW Drawing 3868-46, Y&D Drawing 190842. Scale 1/4' = 1'. - Naval Torpedo Station, Firing Pier, North end of Gould Island in Narragansett Bay, Newport, Newport County, RI

  20. 36. 'Firing Pier, First Floor Plan, Section No. 1,' submitted ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    36. 'Firing Pier, First Floor Plan, Section No. 1,' submitted 29 December 1941 by John Brackett, Consulting Engineer, to Public Works Department, Bureau of Yards & Docks. PW Drawing 3862-46, Y&D Drawing 190836. Scale 1/4' = 1'. - Naval Torpedo Station, Firing Pier, North end of Gould Island in Narragansett Bay, Newport, Newport County, RI

  1. 38. 'Firing Pier, First Floor Plan, Section No. 3,' submitted ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    38. 'Firing Pier, First Floor Plan, Section No. 3,' submitted 29 December 1941 by John Brackett, Consulting Engineer, to Public Works Department, Bureau of Yards & Docks. PW Drawing 3864-46, Y&D Drawing 190838. Scale 1/4' = 1'. - Naval Torpedo Station, Firing Pier, North end of Gould Island in Narragansett Bay, Newport, Newport County, RI

  2. 40. 'Firing Pier, Second Floor Plan, Section No. 1,' submitted ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    40. 'Firing Pier, Second Floor Plan, Section No. 1,' submitted 29 December 1941 by John Brackett, Consulting Engineer, to Public Works Department, Bureau of Yards & Docks. PW Drawing 3866-46, Y&D Drawing 190840. Scale 1/4' = 1'. - Naval Torpedo Station, Firing Pier, North end of Gould Island in Narragansett Bay, Newport, Newport County, RI

  3. 39. 'Firing Pier, First Floor Plan, Section No. 4,' submitted ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    39. 'Firing Pier, First Floor Plan, Section No. 4,' submitted 29 December 1941 by John Brackett, Consulting Engineer, to Public Works Department, Bureau of Yards & Docks. PW Drawing 3865-46, Y&D Drawing 190839. Scale 1/4' = 1'. - Naval Torpedo Station, Firing Pier, North end of Gould Island in Narragansett Bay, Newport, Newport County, RI

  4. 37. 'Firing Pier, First Floor Plan, Section No. 2,' submitted ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    37. 'Firing Pier, First Floor Plan, Section No. 2,' submitted 29 December 1941 by John Brackett, Consulting Engineer, to Public Works Department, Bureau of Yards & Docks. PW Drawing 3863-46, Y&D Drawing 190837. Scale 1/4' = 1. - Naval Torpedo Station, Firing Pier, North end of Gould Island in Narragansett Bay, Newport, Newport County, RI

  5. Front Elevation and Floor Plan in 1893, 1894, and 1909; ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Front Elevation and Floor Plan in 1893, 1894, and 1909; Office End Elevation, Waiting End Elevation, Section A (1894), Section B (1894), Signage (ca. 1908-1911), Map of Rail Lines & Depots on Soldiers' Home - National Home for Disabled Volunteer Soldiers, Pacific Branch, Streetcar Depot, Corner of Pershing & Dewey Avenues, Los Angeles, Los Angeles County, CA

  6. This photographic copy of an engineering drawing shows floor plans, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    This photographic copy of an engineering drawing shows floor plans, sections and elevations of Building E-86, with details typical of the steel frame and "Transite" building construction at JPL Edwards Facility. California Institute of Technology, Jet Propulsion Laboratory, Facilities Engineering and Construction Office: "Casting & Curing, Building E-86, Floor Plan, Elevations & Section," drawing no. E86/6, 25 February 1977. California Institute of Technology, Jet Propulsion Laboratory, Plant Engineering: engineering drawings of structures at JPL Edwards Facility. Drawings on file at JPL Plant Engineering, Pasadena, California - Jet Propulsion Laboratory Edwards Facility, Casting & Curing Building, Edwards Air Force Base, Boron, Kern County, CA

  7. 21. VIEW OF THE FIRST FLOOR PLAN. THE FIRST FLOOR ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    21. VIEW OF THE FIRST FLOOR PLAN. THE FIRST FLOOR WAS USED FOR DEPLETED AND ENRICHED URANIUM FABRICATION. THE ORIGINAL DRAWING HAS BEEN ARCHIVED ON MICROFILM. THE DRAWING WAS REPRODUCED AT THE BEST QUALITY POSSIBLE. LETTERS AND NUMBERS IN THE CIRCLES INDICATE FOOTER AND/OR COLUMN LOCATIONS. - Rocky Flats Plant, Uranium Rolling & Forming Operations, Southeast section of plant, southeast quadrant of intersection of Central Avenue & Eighth Street, Golden, Jefferson County, CO

  8. 22. VIEW OF THE SECOND FLOOR PLAN. THE SECOND FLOOR ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    22. VIEW OF THE SECOND FLOOR PLAN. THE SECOND FLOOR CONTAINS THE AIR PLENUM ND SOME OFFICE SPACE. THE ORIGINAL DRAWING HAS BEEN ARCHIVED ON MICROFILM. THE DRAWING WAS REPRODUCED AT THE BEST QUALITY POSSIBLE. LETTERS AND NUMBERS IN THE CIRCLES INDICATE FOOTER AND/OR COLUMN LOCATIONS. - Rocky Flats Plant, Uranium Rolling & Forming Operations, Southeast section of plant, southeast quadrant of intersection of Central Avenue & Eighth Street, Golden, Jefferson County, CO

  9. FAST CHOPPER DETECTOR HOUSE, TRA665. SECOND FLOOR ADDITION: PLAN, SECTIONS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FAST CHOPPER DETECTOR HOUSE, TRA-665. SECOND FLOOR ADDITION: PLAN, SECTIONS AND DETAILS AS ADDED TO THE EXISTING CHOPPER HOUSE IN 1962. F.C. TORKELSON 842-MTR-665-S-3, 4/1962. INL INDEX NO. 531-0665-60-851-150997, REV. 3. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  10. A&M. TAN633. Hot cell floor plans, elevations, sections. Hole schedule ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    A&M. TAN-633. Hot cell floor plans, elevations, sections. Hole schedule (penetrations through concrete). Swing-door details. Ralph M. Parsons 1229-13-ANP/GE-3-633-A-3. Date: December 1956. Approved by INEEL Classification Office for public release. INNEL index code no. 034-0633-00-693-107317 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  11. ETR HEAT EXCHANGER BUILDING, TRA644. FLOOR PLAN AND SECTIONS. PUMP ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    ETR HEAT EXCHANGER BUILDING, TRA-644. FLOOR PLAN AND SECTIONS. PUMP CUBICLES WITH PUMP MOTORS OUTSIDE CUBICLES. HEAT EXCHANGER EQUIPMENT. COOLANT PIPE TUNNEL ENTERS FROM REACTOR BUILDING. KAISER ETR-5582-MTR-644-A-3, 2/1956. INL INDEX NO. 532-0644-00-486-101294, REV. 6. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  12. PUMP HOUSE FOR MTR WELL NO. 1, TRA601. FLOOR PLAN, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    PUMP HOUSE FOR MTR WELL NO. 1, TRA-601. FLOOR PLAN, ELEVATIONS, SECTION SHOWING WELL CASING, ROOF FRAMING PLAN. AS BUILT. WELL HOUSE FOR WELL NO. 2, TRA-602, WAS IDENTICAL IN ALL PARTICULARS EXCEPT FLOOR DIMENSIONS AND ARRANGEMENT OF PUMP AND ELECTRICAL EQUIPMENT INSIDE. IDAHO OPERATIONS OFFICE MTR-601-IDO-1, 12/1954. INL INDEX NO. 531-0601-00-396-110463, REV. 2. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  13. PROCESS WATER BUILDING, TRA605. FLOOR PLAN AND SECTION OF FLASH ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    PROCESS WATER BUILDING, TRA-605. FLOOR PLAN AND SECTION OF FLASH EVAPORATOR ROOM SHOWING ITS LOCATION ABOVE THE SEAL AND SUMP TANKS. PIPING TAKES WATER FROM SEAL TANK UPWARD TO FLASH EVAPORATORS AND THEN BACK DOWN TO SUMP TANK. BLAW-KNOX 3150-5-6, 8/1950. INL INDEX NO. 531-605-00-098-100011, REV. 3. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  14. 3. Photograph of a line drawing. SHEET 3, FLOOR PLAN, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. Photograph of a line drawing. SHEET 3, FLOOR PLAN, DETAILS OF S EAST AND S WEST CORNERS, TYPICAL DETAIL AT COLUMN U-49 and U-25, TYPICAL SECTION THRU R. R. TRACK IN S WEST CORNER, SECTION THRU PIPE PIT AT COLUMN #P-1; 9-16-1940. Assembly Building for Tank Plant for the Chrysler Corporation, Macomb County, Michigan. Delineator: H. C. B. - Detroit Arsenal, 6501 East Eleven Mile Road, Warren, Macomb County, MI

  15. 160. ARAIII Service building (ARA610). Includes floor plan, north and ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    160. ARA-III Service building (ARA-610). Includes floor plan, north and west elevations, and section details. Aerojet-general 880-area/GCRE-610-A-1. Date: February 1958. Ineel index code no. 063-0610-00-013-102684. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID

  16. 11. Photographic copy of drawing dated February 17, 1908 (Source: ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. Photographic copy of drawing dated February 17, 1908 (Source: Salt River Project) Transformer building, first floor plan and sections (Transformer floor) - Theodore Roosevelt Dam, Transformer House, Salt River, Tortilla Flat, Maricopa County, AZ

  17. FAST CHOPPER DETECTOR HOUSE, TRA665. FIRST FLOOR, PLAN AND SECTION, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FAST CHOPPER DETECTOR HOUSE, TRA-665. FIRST FLOOR, PLAN AND SECTION, AS PROPOSED FOR MODIFICATION IN 1962. CONCRETE WALLS THREE FEET THICK. EXISTING WINDOWS IN MTR AND DETECTOR HOUSE WALLS WERE TO BE FILLED IN WITH HIGH-DENSITY BRICK. NOTE 20-METER MARK, WHERE THE FAST CHOPPER DETECTOR HAD BEEN LOCATED. F.C. TORKELSON 842-MTR-665-S-2, 4/1962. INL INDEX NO. 531-0665-60-851-150996, REV. 5. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  18. SPERTI Gate House at control area (PER603). Floor plan, elevations, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    SPERT-I Gate House at control area (PER-603). Floor plan, elevations, sections. This Gate House replaced the original gate house, for which drawings are no longer extant. F.C. Torkelson 842-SPERT-603-A-1. Date: February 1962. INEEL index no. 760-0603-00-851-151336 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID

  19. 55. Photograph of Original Plan (original plans in the possession ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    55. Photograph of Original Plan (original plans in the possession of the Los Angeles Union Passenger Terminal Corporation) BAGGAGE AND EXPRESS UNITY, STREET LEVEL FLOOR PLAN, SECTION III - Los Angeles Union Passenger Terminal, Tracks & Shed, 800 North Alameda Street, Los Angeles, Los Angeles County, CA

  20. 36 CFR 910.60 - Gross floor area.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 36 Parks, Forests, and Public Property 3 2011-07-01 2011-07-01 false Gross floor area. 910.60 Section 910.60 Parks, Forests, and Public Property PENNSYLVANIA AVENUE DEVELOPMENT CORPORATION GENERAL GUIDELINES AND UNIFORM STANDARDS FOR URBAN PLANNING AND DESIGN OF DEVELOPMENT WITHIN THE PENNSYLVANIA AVENUE...

  1. 36 CFR 910.60 - Gross floor area.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Gross floor area. 910.60 Section 910.60 Parks, Forests, and Public Property PENNSYLVANIA AVENUE DEVELOPMENT CORPORATION GENERAL GUIDELINES AND UNIFORM STANDARDS FOR URBAN PLANNING AND DESIGN OF DEVELOPMENT WITHIN THE PENNSYLVANIA AVENUE...

  2. Dyadic planning of health-behavior change after prostatectomy: a randomized-controlled planning intervention.

    PubMed

    Burkert, Silke; Scholz, Urte; Gralla, Oliver; Roigas, Jan; Knoll, Nina

    2011-09-01

    In this study, we investigated the role of dyadic planning for health-behavior change. Dyadic planning refers to planning health-behavior change together with a partner. We assumed that dyadic planning would affect the implementation of regular pelvic-floor exercise (PFE), with other indicators of social exchange and self-regulation strategies serving as mediators. In a randomized-controlled trial at a German University Medical Center, 112 prostatectomy-patients with partners were randomly assigned to a dyadic PFE-planning condition or one of three active control conditions. Questionnaire data were assessed at multiple time points within six months post-surgery, measuring self-reported dyadic PFE-planning and pelvic-floor exercise as primary outcomes and social exchange (support, control) and a self-regulation strategy (action control) as mediating mechanisms. There were no specific intervention effects with regard to dyadic PFE-planning or pelvic-floor exercise, as two active control groups also showed increases in either of these variables. However, results suggested that patients instructed to plan dyadically still benefited from self-reported dyadic PFE-planning regarding pelvic-floor exercise. Cross-sectionally, received negative control from partners was negatively related with PFE only in control groups and individual action control mediated between self-reported dyadic PFE-planning and PFE for participants instructed to plan PFE dyadically. Longitudinally, action control mediated between self-reported dyadic PFE-planning and pelvic-floor exercise for all groups. Findings provide support for further investigation of dyadic planning in health-behavior change with short-term mediating effects of behavior-specific social exchange and long-term mediating effects of better self-regulation. Copyright © 2011 Elsevier Ltd. All rights reserved.

  3. 7 CFR 1753.26 - Plans and specifications (P&S).

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 11 2011-01-01 2011-01-01 false Plans and specifications (P&S). 1753.26 Section 1753... Buildings § 1753.26 Plans and specifications (P&S). (a) For headquarters and commercial office buildings only, the borrower shall prepare preliminary P&S showing the floor plan and general architectural...

  4. 7 CFR 1753.26 - Plans and specifications (P&S).

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 11 2014-01-01 2014-01-01 false Plans and specifications (P&S). 1753.26 Section 1753... Buildings § 1753.26 Plans and specifications (P&S). (a) For headquarters and commercial office buildings only, the borrower shall prepare preliminary P&S showing the floor plan and general architectural...

  5. 7 CFR 1753.26 - Plans and specifications (P&S).

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 11 2013-01-01 2013-01-01 false Plans and specifications (P&S). 1753.26 Section 1753... Buildings § 1753.26 Plans and specifications (P&S). (a) For headquarters and commercial office buildings only, the borrower shall prepare preliminary P&S showing the floor plan and general architectural...

  6. 7 CFR 1753.26 - Plans and specifications (P&S).

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 11 2012-01-01 2012-01-01 false Plans and specifications (P&S). 1753.26 Section 1753... Buildings § 1753.26 Plans and specifications (P&S). (a) For headquarters and commercial office buildings only, the borrower shall prepare preliminary P&S showing the floor plan and general architectural...

  7. 16. 'Concrete Bridge Over Salt River, Port Kenyon, Humboldt County, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    16. 'Concrete Bridge Over Salt River, Port Kenyon, Humboldt County, California, A.J. Logan, County Surveyor, H.J. Brunnier, Consulting Engineer, March 7, 1919,' showing detail of floor beam at central pier, half section of cantilever slab at end of bridge, floor beam end panels, slab reinforcing, plan of slab reinforcing, diagram of slab bars, typical floor girder. - Salt River Bridge, Spanning Salt River at Dillon Road, Ferndale, Humboldt County, CA

  8. 20. VIEW OF THE BASEMENT FLOOR PLAN. THE BASEMENT AREA ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    20. VIEW OF THE BASEMENT FLOOR PLAN. THE BASEMENT AREA INCLUDES A UTILITY ROOM, PROCESS WASTE STORAGE AND MAINTENANCE AREAS, AND THE ENTRANCE TO AN UNDERGROUND TUNNEL LEADING TO BUILDING 881. THE ORIGINAL DRAWING HAS BEEN ARCHIVED ON MICROFILM. THE DRAWING WAS REPRODUCED AT THE BEST QUALITY POSSIBLE. LETTERS AND NUMBERS IN THE CIRCLES INDICATE FOOTER AND/OR COLUMN LOCATIONS. - Rocky Flats Plant, Uranium Rolling & Forming Operations, Southeast section of plant, southeast quadrant of intersection of Central Avenue & Eighth Street, Golden, Jefferson County, CO

  9. 9 CFR 590.146 - Application for continuous inspection in official plants; approval.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... copies of each print drawing as specified in this section of the complete floor plan, plot plan... zip code or an accurate description of the location. (3) Plot plan of entire premises shall include..., and vehicular loading areas. The plot plan may be drawn to a scale of one-thirty-second inch per foot...

  10. 36. Photocopy of drawing (November 1934 architectural drawings by Burge ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    36. Photocopy of drawing (November 1934 architectural drawings by Burge and Stevens, in possession of the Engineering and Capital Improvements Department of the Atlanta Housing Authority, Atlanta, Georgia). FIRST FLOOR PLAN (WITH VIGNETTES OF THIRD FLOOR) AND BATHROOM SECTIONS OF TECHWOOD PROJECT # 1101, SHEET A-46. - Techwood Homes, McDaniel Dormitory, 581-587 Techwood Drive, Atlanta, Fulton County, GA

  11. 4. "ARCHITECTURAL, FLOOR PLANELEVATIONSSECTIONS, OBSERVATION BUNKERS." Specifications No. ENG (NASA)04353631; ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. "ARCHITECTURAL, FLOOR PLAN-ELEVATIONS-SECTIONS, OBSERVATION BUNKERS." Specifications No. ENG (NASA)04-353-63-1; Drawing No. 60-09-34; sheet 325. Ref. No. A-13. D.O. SERIES 1597/87. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Observation Bunker 1-D-3, Test Area 1-125, northwest end of Altair Boulevard, Boron, Kern County, CA

  12. IET. Coupling station (TAN620), plans and sections. Concrete shielding walls ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    IET. Coupling station (TAN-620), plans and sections. Concrete shielding walls and boron surface treatment. Elevation shows two floor levels, position of periscopes, and stairways. Ralph M. Parsons 902-4-ANP-602-A 325. Date: February 1954. Approved by INEEL Classification Office for public release. INEEL index code no. 035-0620-00-693-106910 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  13. Egade, Mexico.

    ERIC Educational Resources Information Center

    Kubany, Elizabeth

    2001-01-01

    Presents a business school design in Mexico, whose spiral building sits atop a parking structure creating a compact, symbolic form for an arid urban landscape. Includes seven photographs, a floor plan, and sectional drawing. (GR)

  14. Converting Residential Drawing Courses to Metric.

    ERIC Educational Resources Information Center

    Goetsch, David L.

    1980-01-01

    Describes the process of metric conversion in residential drafting courses. Areas of concern are metric paper sizes; metric scale; plot, foundation, floor and electric plans; wall sections; elevations; and heat loss/ heat gain calculations. (SK)

  15. Cool Jazz.

    ERIC Educational Resources Information Center

    Speck, Lawrence W.

    2001-01-01

    Describes the distinctive architectural style of a new dormitory at New Orleans' Tulane University, where architects had to deal with a difficult site, a tightly defined program, a venerable institution, and a colorful locale. Includes nine photographs, floor-plans and sectional drawings. (GR)

  16. Photocopy of plan (in collection of U.S. Coast Guard Civil ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of plan (in collection of U.S. Coast Guard Civil Engineering Unit Providence, Warwick, RI), U.S. Coast Guard Civil Engineering, third district, Sandy Hook L/B Station, Fort Hancock, NJ, boathouse, plot plan, floor plan, elevation. & section., November 8, 1963 Proposed boathouse wharf B, L.A.S. building shown on wharf A - U.S. Coast Guard Sandy Hook Station, Western Docking Structure, West of intersection of Canfield Road & Hartshorne Drive, Highlands, Monmouth County, NJ

  17. Historic American Buildings Survey PHOTOCOPY OF MEASURED DRAWING BY DIETER ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Historic American Buildings Survey PHOTOCOPY OF MEASURED DRAWING BY DIETER SENGLER, 1964 ELEVATION, PLAN AND SECTION OF TYPICAL BAY SHOWING SECOND, THIRD, FIFTEENTH AND SIXTEENTH FLOORS - Monadnock Block, 53 West Jackson Boulevard, Chicago, Cook County, IL

  18. Photocopy of drawing, May 22, 1919. Machine shop alterations, east ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of drawing, May 22, 1919. Machine shop alterations, east wing, first and second floor plans and section. Watertown arsenal engineering division. Drawing number 9222. - Watertown Arsenal, Building No. 313, Talcott Avenue, Watertown, Middlesex County, MA

  19. 75 FR 32673 - Finding of Failure To Submit Section 110 State Implementation Plans for Interstate Transport for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-09

    ... Ms. Gobeail McKinley, Office of Air Quality Planning and Standards, Geographic Strategies Group, Mail... and the U.S. Region II, 290 Broadway, 25th Floor, New Virgin Islands. York, NY 10007-1866. Cristina... Northern Mariana Islands, Guam, Puerto Rico, and the U.S. Virgin Islands. EPA is making a finding of...

  20. 75 FR 70061 - Dealer Floor Plan Pilot Program Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-16

    ... SMALL BUSINESS ADMINISTRATION Dealer Floor Plan Pilot Program Meeting AGENCY: U.S. Small Business... location, date, time, and agenda for a meeting regarding the Dealer Floor Plan Pilot Program established in... Plan Pilot Program meeting will be held on November 16, 2010 from approximately 9 a.m. to 12 p.m...

  1. Accessibility Standards, Illustrated.

    ERIC Educational Resources Information Center

    Jones, Michael A.

    The book sets forth Illinois environmental accessibility standards for disabled persons based on observation and interview data. Photographs, drawings, and detailed floor plans are included in sections dealing with human data (including space requirements for maneuvering wheelchairs, color blindness, incontinence, and severe auditory or visual…

  2. 4. JOB NO. 1347B, SHEET 1, 1927, OIL HOUSE; FORD ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. JOB NO. 1347-B, SHEET 1, 1927, OIL HOUSE; FORD MOTOR COMPANY; FLOOR PLAN, ELEVATIONS AND SECTIONS - Ford Motor Company Long Beach Assembly Plant, Oil House, 700 Henry Ford Avenue, Long Beach, Los Angeles County, CA

  3. Floor Plans Foundation Plan at Bedrock and Subgrade Level ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Floor Plans - Foundation Plan at Bedrock and Subgrade Level Plan - Marshall Space Flight Center, F-1 Engine Static Test Stand, On Route 565 between Huntsville and Decatur, Huntsville, Madison County, AL

  4. 7. Photographic copy of floor plan drawing, dated September 26, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. Photographic copy of floor plan drawing, dated September 26, 1975, Selfridge ANG Base, in possession of Selfridge Base Museum, Mt. Clemens, Michigan. FLOOR PLAN BLDG. 1583. - Selfridge Field, Building Nos. 1582, 1583, 1584, South of East Joy Boulevard, west of Taxiway C, Mount Clemens, Macomb County, MI

  5. 6. Photographic copy of floor plan drawing, dated August 10, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. Photographic copy of floor plan drawing, dated August 10, 1968, Selfridge ANG Base, in possession of Selfridge Base Museum, Mt. Clemens, Michigan. FLOOR PLANS BLDGS. 1582 & 1584. - Selfridge Field, Building Nos. 1582, 1583, 1584, South of East Joy Boulevard, west of Taxiway C, Mount Clemens, Macomb County, MI

  6. 9. Photographic copy of first and second floor plans, undated, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. Photographic copy of first and second floor plans, undated, Department of the Air Force, Air Defense Command Installations, Washington, D.C., in possession of Selfridge Base Museum, Mt. Clemens, Michigan. FLOOR PLANS. - Selfridge Field, Building No. 509, Sugarbush Road east of West Perimeter Road, Mount Clemens, Macomb County, MI

  7. 6. Photographic copy of floor plan drawing, dated August 18, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. Photographic copy of floor plan drawing, dated August 18, 1968, Department of the Air Force Air Defense Command Installations, in possession of Selfridge Base Museum, Mt. Clemens, Michigan. FLOOR PLAN BLDG. 1585. - Selfridge Field, Building No. 1585, South of East Joy Boulevard, west of Taxiway C, Mount Clemens, Macomb County, MI

  8. Photographic copy of floor plan drawing, dated March 7, 1968, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photographic copy of floor plan drawing, dated March 7, 1968, Department of the Air Force Air Defense Command Installations, in possession of Selfridge Base Museum, Mt. Clemens, Michigan. FLOOR PLAN BLDG. 1575 - Selfridge Field, Building No. 1575, South of East Joy Boulevard, west of Taxiway C, Mount Clemens, Macomb County, MI

  9. Middle-Level Preservice Mathematics Teachers' Mental Representations of Classroom Floor Plans

    ERIC Educational Resources Information Center

    Matteson, Shirley M.; Ganesh, Bibi S.; Coward, Fanni L.; Patrick, Patricia

    2012-01-01

    This study reports the results of an innovative assignment in which preservice teachers' mental representations were examined through drawing floor plans of an "ideal middle-level mathematics classroom." The 41 middle-level mathematics preservice teachers created two floor plans, one at the beginning of the semester and the other for the…

  10. ETR, TRA642. FLOOR PLAN UNDER BALCONY ON CONSOLE FLOOR. MOTORGENERATOR ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    ETR, TRA-642. FLOOR PLAN UNDER BALCONY ON CONSOLE FLOOR. MOTOR-GENERATOR SETS AND OTHER ELECTRICAL EQUIPMENT. PHILLIPS PETROLEUM COMPANY ETR-D-1781, 7/1960. INL INDEX NO. 532-0642-00-706-020384, REV. 1. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  11. 6. Photocopy of drawing (1976 structural drawing by the Space ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. Photocopy of drawing (1976 structural drawing by the Space and Missile Test Center, VAFB, USAF) FLOOR PLAN, ELEVATIONS, SECTIONS, AND DETAILS FOR THE PYROTEST AND STORAGE BUILDING, SHEET S22 - Vandenberg Air Force Base, Space Launch Complex 3, Pyrotechnic Shed, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  12. 114. Photocopy of drawing (1964 architectural drawing by Koebig & ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    114. Photocopy of drawing (1964 architectural drawing by Koebig & Koebig Inc.) ADDITION TO LAUNCH OPERATIONS BUILDING; POINT ARGUELLO LAUNCH COMPLEX ONE; FLOOR PLANS, SECTIONS, AND DETAILS; SHEET A-1 - Vandenberg Air Force Base, Space Launch Complex 3, Launch Operations Building, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  13. 137. ARAII Building ARA602 floor plan as it appeared in ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    137. ARA-II Building ARA-602 floor plan as it appeared in 1980 when electrical modifications were being made. Shows partial layout of floor plan. EG&G Idaho, Inc. 1570-ARA-II-602-E-3. Date: April 1980. Ineel index code no. 070--0602-10-220-159761. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID

  14. 29. FLOOR PLAN OF WASTE CALCINATION FACILITY SHOWING MAIN ABOVEGRADE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    29. FLOOR PLAN OF WASTE CALCINATION FACILITY SHOWING MAIN ABOVE-GRADE FLOOR LEVEL. INEEL DRAWING NUMBER 200-0633-00-287-106354. FLUOR NUMBER 5775-CPP-633-A-4. - Idaho National Engineering Laboratory, Old Waste Calcining Facility, Scoville, Butte County, ID

  15. SECOND FLOOR AND ROOF PLANS. United Engineering Company Ltd., Alameda ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    SECOND FLOOR AND ROOF PLANS. United Engineering Company Ltd., Alameda Shipyard, Ship Repair Facilities, Office Building. Second floor plan, and roof plan. John Hudspeth, Architect, at foot of Main Street, Alameda, Calif. Sheet no. A2 of 8 sheets, Plan no. 10,007. Scale 1/8 inch to the foot. March 18, 1942, last revised 9/22/43. U.S. Navy, Bureau of Yards & Docks, Contract no. bs 76. Approved for construction October 9, 1943. blueprint - United Engineering Company Shipyard, Office Building No. 137, 2900 Main Street, Alameda, Alameda County, CA

  16. LOFT. Containment and service building (TAN650) ground floor plan. Penetrations ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    LOFT. Containment and service building (TAN-650) ground floor plan. Penetrations in dome wall. Shielded personnel maze at airlock door. Reactor chamber floor hatches and holddowns. Rails in concrete floor. Kaiser engineers 6413-11-STEP/LOFT-650-A-2. Date: October 1964. INEEL index code no. 036-650-00-486-122214 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  17. 131. ARAII Administration building (ARA613) floor plans for first and ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    131. ARA-II Administration building (ARA-613) floor plans for first and second floors. Includes roof plan. Shows use of rooms as offices, laboratory, conference room. F.C. Torkelson Company 842-area/SL-1-613-A-1. Date: October 1958. Ineel index code no. 070-0613-00-851-150718. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID

  18. Floor Plans Fuel Tank Support, Fuel Platform, and LOX ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Floor Plans - Fuel Tank Support, Fuel Platform, and LOX Platform Plans - Marshall Space Flight Center, F-1 Engine Static Test Stand, On Route 565 between Huntsville and Decatur, Huntsville, Madison County, AL

  19. Floor Plans Rolling Platform, Tech Systems Platform, and Load ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Floor Plans - Rolling Platform, Tech Systems Platform, and Load Platform Plans - Marshall Space Flight Center, F-1 Engine Static Test Stand, On Route 565 between Huntsville and Decatur, Huntsville, Madison County, AL

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pool, Karl N.; Minette, Michael J.; Wahl, Jon H.

    On September 28, 2015, debris collected from the PRF (236-Z) canyon floor, Pan J, was observed to exhibit chemical reaction. The material had been transferred from the floor pan to a collection tray inside the canyon the previous Friday. Work in the canyon was stopped to allow Industrial Hygiene to perform monitoring of the material reaction. Canyon floor debris that had been sealed out was sequestered at the facility, a recovery plan was developed, and drum inspections were initiated to verify no additional reactions had occurred. On October 13, in-process drums containing other Pan J material were inspected and showedmore » some indication of chemical reaction, limited to discoloration and degradation of inner plastic bags. All Pan J material was sealed back into the canyon and returned to collection trays. Based on the high airborne levels in the canyon during physical debris removal, ETGS (Encapsulation Technology Glycerin Solution) was used as a fogging/lock-down agent. On October 15, subject matter experts confirmed a reaction had occurred between nitrates (both Plutonium Nitrate and Aluminum Nitrate Nonahydrate (ANN) are present) in the Pan J material and the ETGS fixative used to lower airborne radioactivity levels during debris removal. Management stopped the use of fogging/lock-down agents containing glycerin on bulk materials, declared a Management Concern, and initiated the Potential Inadequacy in the Safety Analysis determination process. Additional drum inspections and laboratory analysis of both reacted and unreacted material are planned. This report compiles the results of many different sample analyses conducted by the Pacific Northwest National Laboratory on samples collected from the Plutonium Reclamation Facility (PRF) floor pans by the CH2MHill’s Plateau Remediation Company (CHPRC). Revision 1 added Appendix G that reports the results of the Gas Generation Rate and methodology. The scope of analyses requested by CHPRC includes the determination of common anions, gamma spectrometry, metals, corrosivity, organics and alpha spectrometry (note: alpha spectrometry was cancelled during the performance of this work with concurrence from CHPRC). Results may help elucidate the components that led to the unexpected reaction in the canyon as well as inform the radiological and hazardous characteristics. The specific anions, gamma emitters, organics and metals requested by CHPRC are provided in the analytical reports sections. The individual analyses were conducted under the Plutonium Finishing Plant (PFP) Floor Pan Evaluation Project Quality Assurance Project Plan (PFP Floor Pan Evaluation QAPP, Revision 0.) developed by PNNL specifically for this project. The final reports for each analysis set are included in this compilation of the results. Each package was reviewed under the PFP Floor Pan Evaluation Project Quality Assurance Project Plan so no additional reviews were conducted in this compilation task. The Gas Generation Rates in Appendix G were conducted under the PNNL “How Do I…” quality assurance program and were NOT conducted under the Plutonium Finishing Plant (PFP) Floor Pan Evaluation Project Quality Assurance Project Plan (PFP Floor Pan Evaluation QAPP, Revision 0.).« less

  1. 23. VIEW OF THE FIRST FLOOR PLAN. THE FIRST FLOOR ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    23. VIEW OF THE FIRST FLOOR PLAN. THE FIRST FLOOR HOUSED ADMINISTRATIVE OFFICES, THE CENTRAL COMPUTING, UTILITY SYSTEMS, ANALYTICAL LABORATORIES, AND MAINTENANCE SHOPS. THE ORIGINAL DRAWING HAS BEEN ARCHIVED ON MICROFILM. THE DRAWING WAS REPRODUCED AT THE BEST QUALITY POSSIBLE. LETTERS AND NUMBERS IN THE CIRCLES INDICATE FOOTER AND/OR COLUMN LOCATIONS. - Rocky Flats Plant, General Manufacturing, Support, Records-Central Computing, Southern portion of Plant, Golden, Jefferson County, CO

  2. Building Type Basics for College and University Facilities. Building Type Basics.

    ERIC Educational Resources Information Center

    Neuman, David J.; Kliment, Stephen A.

    This book provides indepth information that is needed to initiate a variety of building projects on a diverse range of college and university campuses. Filled with project photographs, diagrams, floor plans, sections, and details, the book combines highly illustrative, specialized material from industry leaders with nuts-and-bolts design…

  3. 115. Stage Level floor structure. Detail of the ends of ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    115. Stage Level floor structure. Detail of the ends of three movable stage floor sections. An inclined steel angle track attached to the web of the floor beam allows the sections to roll under the fixed floor. The upper section of the inclined track is hinged so it can be moved upward by a cam mechanism to raise the end of the movable section level with the stage floor. A similar mechanism was used to open and close the floor sections for the star lifts (see sheet 4 of 9, note 6; sheet 8 of 9, details 5, 6A and 6B; sheet 6 of 9, notes 2A, 2B, and 3; and photo IL-1007-120). The pulley, and tongue extending out from the end of the movable section, were used to move the sections back and forth. - Auditorium Building, 430 South Michigan Avenue, Chicago, Cook County, IL

  4. 7. FLOOR PLAN, PLOT PLAN, ELEVATIONS, SHEET NO. 11044/1 OF ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. FLOOR PLAN, PLOT PLAN, ELEVATIONS, SHEET NO. 1-10-44/1 OF 11. (NOTE: BUILDINGS 821-823 WERE CONSTRUCTED FROM A SINGLE SET OF PLANS. SOME DRAWINGS ARE TYPICAL OF ALL 3 STRUCTURES, CERTAIN OTHER DRAWINGS IN THE SAME SET ARE BUILDING-SPECIFIC.) - Oakland Army Base, Storehouse Type, Ukraine & Maritime Streets, Oakland, Alameda County, CA

  5. FLOOR PLAN OF MAIN PROCESSING BUILDING (CPP601), SECOND FLOOR SHOWING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FLOOR PLAN OF MAIN PROCESSING BUILDING (CPP-601), SECOND FLOOR SHOWING PROCESS MAKEUP AREA AND EIGHTEEN CELLS AND ADJOINING REMOTE ANALYTICAL FACILITY (CPP-627) SHOWING COLD LAB, DECONTAMINATION ROOM, MULTICURIE CELL ROOM, AND OFFICES. TO LEFT ARE LABORATORY BUILDING (CPP-602) AND MAINTENANCE BUILDING (CPP-630). INL DRAWING NUMBER 200-0601-00-706-051980. ALTERNATE ID NUMBER CPP-E-1980. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID

  6. FLOOR PLAN OF MAIN PROCESSING BUILDING (CPP601), FIRST FLOOR SHOWING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FLOOR PLAN OF MAIN PROCESSING BUILDING (CPP-601), FIRST FLOOR SHOWING SAMPLE CORRIDORS AND EIGHTEEN CELLS AND ADJOINING REMOTE ANALYTICAL FACILITY (CPP-627) SHOWING REMOTE ANALYTICAL FACILITIES LAB, DECONTAMINATION ROOM, AND MULTICURIE CELL ROOM. TO LEFT ARE LABORATORY BUILDING (CPP-602) AND MAINTENANCE BUILDING (CPP-630). INL DRAWING NUMBER 200-0601-00-706-051979. ALTERNATE ID NUMBER CPP-E-1979. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID

  7. FIRST FLOOR PLAN AND SCHEDULES. United Engineering Company Ltd., Alameda ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FIRST FLOOR PLAN AND SCHEDULES. United Engineering Company Ltd., Alameda Shipyard, Ship Repair Facilities, Office Building. First floor plan, door transom schedule, interior finish schedule, sash schedule, exterior color schedule, and location plot plan. John Hudspeth, Architect, at foot of Main Street, Alameda, Calif. Sheet no. Al of 8 sheets, Plan no. 10,007. Scale 1/8 inch to the foot. March 18, 1942, last revised 9/25/43. U.S. Navy, Bureau of Yards & Docks, Contract no. bs 76. Approved for construction October 9, 1943. blueprint - United Engineering Company Shipyard, Office Building No. 137, 2900 Main Street, Alameda, Alameda County, CA

  8. A&M. TAN607 floor plans. Shows three floor levels of pool, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    A&M. TAN-607 floor plans. Shows three floor levels of pool, hot shop, and warm shop. Includes view of pool vestibule, personnel labyrinth, location of floor rails, and room numbers of office areas, labs, instrument rooms, and stairways. This drawing was re-drawn to show as-built features in 1993. Ralph M. Parsons 902-3-ANP-607-A 96. Date of original: December 1952. Approved by INEEL Classification Office for public release. INEEL index code no. 034-0607-00-693-106748 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  9. 3. PHOTOCOPY OF DRAWING (1960 ARCHITECTURAL DRAWING BY THE RALPH ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. PHOTOCOPY OF DRAWING (1960 ARCHITECTURAL DRAWING BY THE RALPH M. PARSONS COMPANY) FLOOR PLAN, ELEVATIONS, AND SECTION FOR THE SAMOS TECHNICAL SUPPORT BUILDING (BLDG. 761; NOW CALLED SLC-3 AIR FORCE BUILDING), SHEET A14 - Vandenberg Air Force Base, Space Launch Complex 3, SLC-3 Air Force Building, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  10. Photocopy of drawing (original drawing of Sewage Treatment Plant ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of drawing (original drawing of Sewage Treatment Plant - No. 1 Pump House in possession of MacDill Air Force Base, Civil Engineering, Tampa, Florida; 1940 architectural drawings by Construction Division, Office of the Quartermaster General) FLOOR PLANS AND SECTIONS - MacDill Air Force Base, Pump House No. 1, Hillsborough Garden Drive & Tampa Boulevard, Tampa, Hillsborough County, FL

  11. First Floor Plan U.S. Veterans Hospital, Jefferson Barracks, Therapeutic ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    First Floor Plan - U.S. Veterans Hospital, Jefferson Barracks, Therapeutic Exercise Building, VA Medical Center, Jefferson Barracks Division 1 Jefferson Barracks Drive, Saint Louis, Independent City, MO

  12. MTRETR MAINTENANCE SHOP, TRA653. FLOOR PLAN FOR FIRST FLOOR: MACHINE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    MTR-ETR MAINTENANCE SHOP, TRA-653. FLOOR PLAN FOR FIRST FLOOR: MACHINE SHOP, ELECTRICAL AND INSTRUMENT SHOP, TOOL CRIB, ELECTRONIC SHOP, LOCKER ROOM, SPECIAL TEMPERATURE CONTROLLED ROOM, AND OFFICES. "NEW" ON DRAWING REFERS TO REVISION OF 11/1956 DRAWING ON WHICH AREAS WERE DESIGNATED AS "FUTURE." HUMMEL HUMMEL & JONES 810-MTR-ETR-653-A-7, 5/1957. INL INDEX NO. 532-0653-00-381-101839, REV. 2. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  13. A&M. TAN607 floor plan for first floor. Shows stepped door ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    A&M. TAN-607 floor plan for first floor. Shows stepped door plug design from hot shop into special services cubicle, cubicle windows, and other details. This drawing was re-drawn to show as-built conditions in 1985. Ralph M. Parsons 902-3-ANP-607-A 99. Date of original: January 1955. Approved by INEEL Classification Office for public release. INEEL index code no. 034-0607-00-693-106751 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  14. Section NN, showing steel roof trusses, mezzanine iron railing, first ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Section NN, showing steel roof trusses, mezzanine iron railing, first floor doors, etc. San Bernardino Valley Union Junior College, Library Building. Also includes steel truss roof plan and a small stress diagram of the truss. Howard E. Jones, Architect, San Bernardino, California. Sheet 8, job no. 315. Scales 1/2 inch to the foot (section), and 1/8 and 1/16 inch to the foot. No date given on sheet (probably March or April, 1927). - San Bernardino Valley College, Library, 701 South Mount Vernon Avenue, San Bernardino, San Bernardino County, CA

  15. 5. Photographic copy of architectural floor plans for Officers' Quarters ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. Photographic copy of architectural floor plans for Officers' Quarters "A" & "B": Taylor & Barnes, Architects & Engineers, 803 W. Third Street, Los Angeles California, O.C.E. Office of Civil Engineer Job No. Muroc ESA 210-48 and 210-49, Military Construction: Muroc Flight Test Base, Muroc, California, Warehouses and Additional Housing for Officers: Officers Quarters, Floor Plan, Foundation Plan & Details, Sheet No. 12 of 16, May 1945. Reproduced from the holdings of the National Archives, Pacific Southwest Region - Edwards Air Force Base, North Base, Officers' Quarters A, North Base Road, Boron, Kern County, CA

  16. 7. ARCHITECTURAL ELEVATIONS AND FLOOR PLANS OF OFFICE, SHEET 1 ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. ARCHITECTURAL ELEVATIONS AND FLOOR PLANS OF OFFICE, SHEET 1 OF 1, 8' X 10' NEGATIVE MADE FROM COPIES OF ORIGINAL PLANS, MAY 21, 1913; WALLOWA-WHITMAN NATIONAL FOREST SUPERVISOR'S OFFICE, BAKER CITY, OREGON - Wallowa Ranger Station, Office, 602 First Street, Wallowa, Wallowa County, OR

  17. Photocopy of floor plan of the C.B. & Q. R.R ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of floor plan of the C.B. & Q. R.R roundhouse and locomotive shops. June 1980. - Chicago, Burlington & Quincy Railroad, Roundhouse & Shops, Broadway & Spring Streets, Aurora, Kane County, IL

  18. 145. ELECTRONICS SHOP (BUILDING 60), FIRST FLOOR PLAN AND ELEVATION, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    145. ELECTRONICS SHOP (BUILDING 60), FIRST FLOOR PLAN AND ELEVATION, CHARLES A. MAGUIRE, MARCH 25, 1952. PWD 10332. - Quonset Point Naval Air Station, Roger Williams Way, North Kingstown, Washington County, RI

  19. 5. ARCHITECTURAL ELEVATIONS AND FLOOR PLANS OF GARAGE, SHEET 1 ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. ARCHITECTURAL ELEVATIONS AND FLOOR PLANS OF GARAGE, SHEET 1 OF 1, 8' X 10' NEGATIVE AND PRINT MADE FROM COPIES OF ORIGINAL PLANS, MAY 15, 1936, WALLOWA-WHITMAN NATIONAL FOREST SUPERVISOR'S, OFFICE, BAKER CITY, OREGON. - Wallowa Ranger Station, Garage, 602 First Street, Wallowa, Wallowa County, OR

  20. 5. ARCHITECTURAL ELEVATIONS AND FLOOR PLAN OF GAS HOUSE, SHEET ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. ARCHITECTURAL ELEVATIONS AND FLOOR PLAN OF GAS HOUSE, SHEET 1 OF 1, 8' X 10' NEGATIVE AND PRINT MADE FROM COPIES OF ORIGINAL PLANS, MAY 18, 1936, WALLOWA-WHITMAN NATIONAL FOREST SUPERVISOR'S, OFFICE, BAKER CITY, OREGON. - Wallowa Ranger Station, Gas House, 602 First Street, Wallowa, Wallowa County, OR

  1. 8. FLOOR PLANS OF FIRE EQUIPMENT BUILDING, SHEET 2 OF ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. FLOOR PLANS OF FIRE EQUIPMENT BUILDING, SHEET 2 OF 2, 8' X 10' NEGATIVE AND PRINT MADE FROM COPIES OF ORIGINAL PLANS, MAY 6, 1936, WALLOWA-WHITMAN NATIONAL FOREST SUPERVISOR'S OFFICE, BAKER CITY, OREGON. - Wallowa Ranger Station, Fire Equipment Building, 602 First Street, Wallowa, Wallowa County, OR

  2. 11. Historic American Buildings Survey Photocopy PRINCIPAL FLOOR PLAN, SOUTH ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. Historic American Buildings Survey Photocopy PRINCIPAL FLOOR PLAN, SOUTH SIDE ELEVATION ARCHITECT'S ORIGINAL PLAN Restricted: Not to be reproduced without written permission from Beinecke Rare Books Library, Yale University, New Haven, Connecticut - John Pitkin Norton House, 52 Hillhouse Avenue, New Haven, New Haven County, CT

  3. 18. Historic American Buildings Survey, 1932 measured drawing from old ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    18. Historic American Buildings Survey, 1932 measured drawing from old Philadelphia Survey, photocopy courtesy of the Free Library of Philadelphia BASEMENT FLOOR PLAN AND THIRD FLOOR PLAN. - Woodford, Philadelphia, Philadelphia County, PA

  4. 17. Historic American Buildings Survey, 1932 measured drawing from old ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    17. Historic American Buildings Survey, 1932 measured drawing from old Philadelphia Survey, photocopy courtesy of the Free Library of Philadelphia FIRST FLOOR PLAN AND SECOND FLOOR PLAN. - Woodford, Philadelphia, Philadelphia County, PA

  5. 18. Power plant engine piping floor plan, sheet 71 of ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    18. Power plant engine piping floor plan, sheet 71 of 130 - Naval Air Station Fallon, Power Plant, 800 Complex, off Carson Road near intersection of Pasture & Berney Roads, Fallon, Churchill County, NV

  6. 9. PHOTOCOPY, FOUNDATION AND FLOORING PLANS FOR ADMINISTRATION BUILDING. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. PHOTOCOPY, FOUNDATION AND FLOORING PLANS FOR ADMINISTRATION BUILDING. - NIKE Missile Base SL-40, Administration Building, East central portion of base, southeast of Mess Hall, northeast of HIPAR Equipment Building, Hecker, Monroe County, IL

  7. Photocopy of drawing (this photograph is an 8" x 10" ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of drawing (this photograph is an 8" x 10" copy of an 8" x 10" negative; 1990 original architectural drawing located at Building No. 458, NAS Pensacola, Florida) Quarters "4" as built floor plans, architectural floor plan (first floor), sheet 1 of 2 - U.S. Naval Air Station, Senior Officers' Quarters Q-4, Q-4 North Avenue, Pensacola, Escambia County, FL

  8. Photocopy of drawing (this photograph is an 8" x 10" ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of drawing (this photograph is an 8" x 10" copy of an 8" x 10" negative; 1990 original architectural drawing located at Building No. 458, NAS Pensacola, Florida) Quarters "4" as built floor plans, architectural floor plan (second floor), sheet 2 of 2 - U.S. Naval Air Station, Senior Officers' Quarters Q-4, Q-4 North Avenue, Pensacola, Escambia County, FL

  9. Photocopy of drawing (this photograph is an 8" x 10" ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of drawing (this photograph is an 8" x 10" copy of an 8" x 10" negative; 1991 original architectural drawing located at Building No. 458, NAS Pensacola, Florida) INTERIOR MODIFICATION SECOND FLOOR, BUILDING NO. 1, ARCHITECTURAL PLANS, SECTIONS AND SCHEDULES, SHEET 1 OF 3 - U.S. Naval Air Station, Ship Carpenter's Workshop, 368 South Avenue, Pensacola, Escambia County, FL

  10. Photocopy of drawing (original drawing of Armament & Instrument Inspection ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of drawing (original drawing of Armament & Instrument Inspection and Adjustment Bldg. in possession of MacDill Air Force Base, Civil Engineering, Tampa, Florida; 1941 architectural drawings by Construction Division, Office of the Quartermaster General) FIRST FLOOR PLAN, SECTIONS, AND DETAILS - MacDill Air Force Base, Armament & Instrument Inspection & Adjustment Building, 7807 Hanger Loop Drive, Tampa, Hillsborough County, FL

  11. The Langley 14- by 22-Foot Subsonic Tunnel: Description, Flow Characteristics, and Guide for Users

    NASA Technical Reports Server (NTRS)

    Gentry, Garl L., Jr.; Quinto, P. Frank; Gatlin, Gregory M.; Applin, Zachary T.

    1990-01-01

    The Langley 14- by 22-foot Subsonic Tunnel is a closed circuit, single-return atmospheric wind tunnel with a test section that can be operated in a variety of configurations (closed, slotted, partially open, and open). The closed test section configuration is 14.5 ft high by 21.75 ft wide and 50 ft long with a maximum speed of about 338 ft/sec. The open test section configuration has a maximum speed of about 270 ft/sec, and is formed by raising the ceiling and walls, to form a floor-only configuration. The tunnel may be configured with a moving-belt ground plane and a floor boundary-layer removal system at the entrance to the test section for ground effect testing. In addition, the tunnel had a two-component laser velocimeter, a frequency modulated (FM) tape system for dynamic data acquisition, flow visualization equipment, and acoustic testing capabilities. Users of the 14- by 22-foot Subsonic Tunnel are provided with information required for planning of experimental investigations including test hardware and model support systems.

  12. Second floor plan. (Also includes a roof plan and finish ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Second floor plan. (Also includes a roof plan and finish schedule.) March Air Force Base, Riverside, California, Combat Operations Center, Combat Operations Building. By Moffatt and Nichol, Engineers, 122 West Fifth Street, Long Beach, California; for the Corps of Engineers, U.S. Army, Office of the District Engineer, Los Angeles, California. Drawing no. AW-60-02-03, sheet no. 13, approved March, 1962; specifications no. OCI-62-66; D.O. series AW 1596/13, Rev. "C"; file drawer 1290. Last revised 7 February 1984. Roof plan scale one-sixteenth inch to one foot; second floor plan scale one-eighth inch to one foot. 28.75x41 inches. pencil on paper - March Air Force Base, Strategic Air Command, Combat Operations Center, 5220 Riverside Drive, Moreno Valley, Riverside County, CA

  13. FLOOR PLAN Dyess Air Force Base, Atlas F Missle ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FLOOR PLAN - Dyess Air Force Base, Atlas F Missle Site S-8, Launch Control Center (LCC), Approximately 3 miles east of Winters, 500 feet southwest of Highway 17700, northwest of Launch Facility, Winters, Runnels County, TX

  14. 57. PLANS OF FOURTH AND FIFTH FLOOR ADDITIONS TO BUILDINGS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    57. PLANS OF FOURTH AND FIFTH FLOOR ADDITIONS TO BUILDINGS No. 2 and 4, DATED JUNE 24, 1937; SCHMIDT, GARDEN AND ERICKSON, ARCHITECTS - Underwriters' Laboratories, 207-231 East Ohio Street, Chicago, Cook County, IL

  15. Floor Plans Level 15 Load Platform, Level 17 Lower ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Floor Plans - Level 15 Load Platform, Level 17 Lower Platform, Level 22 and Upper Platform, and Level 27 - Marshall Space Flight Center, Saturn V S-IC Static Test Facility, West Test Area, Huntsville, Madison County, AL

  16. 276. Photocopied July 1978. (QMC) FLOOR PLANS AND FRONT ELEVATION ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    276. Photocopied July 1978. (QMC) FLOOR PLANS AND FRONT ELEVATION OF THE QUINCY SCHOOL (C. 1895), SHOWING ADDITION TO ORIGINAL STRUCTURE, BUILT C. 1867. BURNED IN 1927. - Quincy Mining Company, Hancock, Houghton County, MI

  17. 9. BUILDING 65 ADDITION. LASER SAFETY TEAM. FLOOR PLAN, ELEVATIONS, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. BUILDING 65 ADDITION. LASER SAFETY TEAM. FLOOR PLAN, ELEVATIONS, ETC. March 21, 1973 - Frankford Arsenal, Building No. 65, South of Tacony Street between Bridge Street & tracks of former Pennsylvania Railroad, Philadelphia, Philadelphia County, PA

  18. Floor Plan, Axonometric View, Site Location Key, Cesar Chavez Fasting ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Floor Plan, Axonometric View, Site Location Key, Cesar Chavez Fasting Room Diagram - Forty Acres, Tomasa Zapata Mireles Co-op Building , 30168 Garces Highway (Northwest Corner of Garces Highway and Mettler Avenue), Delano, Kern County, CA

  19. Crashworthy airframe design concepts: Fabrication and testing

    NASA Technical Reports Server (NTRS)

    Cronkhite, J. D.; Berry, V. L.

    1982-01-01

    Crashworthy floor concepts applicable to general aviation aircraft metal airframe structures were investigated. Initially several energy absorbing lower fuselage structure concepts were evaluated. Full scale floor sections representative of a twin engine, general aviation airplane lower fuselage structure were designed and fabricated. The floors featured an upper high strength platform with an energy absorbing, crushable structure underneath. Eighteen floors were fabricated that incorporated five different crushable subfloor concepts. The floors were then evaluated through static and dynamic testing. Computer programs NASTRAN and KRASH were used for the static and dynamic analysis of the floor section designs. Two twin engine airplane fuselages were modified to incorporate the most promising crashworthy floor sections for test evaluation.

  20. 24. VIEW OF THE SECOND FLOOR PLAN. ENRICHED URANIUM AND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    24. VIEW OF THE SECOND FLOOR PLAN. ENRICHED URANIUM AND STAINLESS STEEL WEAPONS COMPONENT PRODUCTION-RELATED ACTIVITIES OCCURRED PRIMARILY ON THE SECOND FLOOR. THE ORIGINAL DRAWING HAS BEEN ARCHIVED ON MICROFILM. THE DRAWING WAS REPRODUCED AT THE BEST QUALITY POSSIBLE. LETTERS AND NUMBERS IN THE CIRCLES INDICATE FOOTER AND/OR COLUMN LOCATIONS. - Rocky Flats Plant, General Manufacturing, Support, Records-Central Computing, Southern portion of Plant, Golden, Jefferson County, CO

  1. 40 CFR Table 5 to Subpart IIIii of... - Required Elements of Floor-Level Mercury Vapor Measurement and Cell Room Monitoring Plans

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Mercury Vapor Measurement and Cell Room Monitoring Plans 5 Table 5 to Subpart IIIII of Part 63 Protection... Hazardous Air Pollutants: Mercury Emissions From Mercury Cell Chlor-Alkali Plants Pt. 63, Subpt. IIIII... and Cell Room Monitoring Plans Your Floor-Level Mercury Vapor Measurement Plan required by § 63.8192(d...

  2. 40 CFR Table 5 to Subpart IIIii of... - Required Elements of Floor-Level Mercury Vapor Measurement and Cell Room Monitoring Plans

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Mercury Vapor Measurement and Cell Room Monitoring Plans 5 Table 5 to Subpart IIIII of Part 63 Protection... Hazardous Air Pollutants: Mercury Emissions From Mercury Cell Chlor-Alkali Plants Pt. 63, Subpt. IIIII... and Cell Room Monitoring Plans Your Floor-Level Mercury Vapor Measurement Plan required by § 63.8192(d...

  3. 40 CFR Table 5 to Subpart IIIii of... - Required Elements of Floor-Level Mercury Vapor Measurement and Cell Room Monitoring Plans

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Mercury Vapor Measurement and Cell Room Monitoring Plans 5 Table 5 to Subpart IIIII of Part 63 Protection... Hazardous Air Pollutants: Mercury Emissions From Mercury Cell Chlor-Alkali Plants Pt. 63, Subpt. IIIII... and Cell Room Monitoring Plans Your Floor-Level Mercury Vapor Measurement Plan required by § 63.8192(d...

  4. 40 CFR Table 5 to Subpart IIIii of... - Required Elements of Floor-Level Mercury Vapor Measurement and Cell Room Monitoring Plans

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Mercury Vapor Measurement and Cell Room Monitoring Plans 5 Table 5 to Subpart IIIII of Part 63 Protection... Hazardous Air Pollutants: Mercury Emissions From Mercury Cell Chlor-Alkali Plants Pt. 63, Subpt. IIIII... and Cell Room Monitoring Plans Your Floor-Level Mercury Vapor Measurement Plan required by § 63.8192(d...

  5. 40 CFR Table 5 to Subpart IIIii of... - Required Elements of Floor-Level Mercury Vapor Measurement and Cell Room Monitoring Plans

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Mercury Vapor Measurement and Cell Room Monitoring Plans 5 Table 5 to Subpart IIIII of Part 63 Protection... Hazardous Air Pollutants: Mercury Emissions From Mercury Cell Chlor-Alkali Plants Pt. 63, Subpt. IIIII... and Cell Room Monitoring Plans Your Floor-Level Mercury Vapor Measurement Plan required by § 63.8192(d...

  6. 8. Photocopy of Station Grounding drawing showing floor plans (from ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. Photocopy of Station Grounding drawing showing floor plans (from the BPA Engineering Vault, Drawing 005319, 3 May 1939) - Bonneville Power Administration South Bank Substation, I-84, South of Bonneville Dam Powerhouse, Bonneville, Multnomah County, OR

  7. 73. New addition building 500 floor plan, drawing number AW600201, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    73. New addition building 500 floor plan, drawing number AW-60-02-01, dated 26 January, 1970 - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Headquarters Building, 901 SAC Boulevard, Bellevue, Sarpy County, NE

  8. 72. SAC control center underground structure lower floor plan, drawing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    72. SAC control center underground structure lower floor plan, drawing number 32-02-03, dated 1 February 1955 - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Headquarters Building, 901 SAC Boulevard, Bellevue, Sarpy County, NE

  9. 7. Photo copy of blue print, (original in Forest Service ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. Photo copy of blue print, (original in Forest Service Office, Elkins, WV), November 1933. FIRST FLOOR PLAN, SECOND FLOOR PLAN. - Parsons Nursery, Manager's Residence, South side of U.S. Route 219, Parsons, Tucker County, WV

  10. 8. PHOTOCOPY, ARCHITECTURAL FLOOR PLAN AND DETAIL DRAWING OF UNDERGROUND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. PHOTOCOPY, ARCHITECTURAL FLOOR PLAN AND DETAIL DRAWING OF UNDERGROUND STORAGE MAGAZINES AND LAUNCHER-LOADER ASSEMBLIES. - NIKE Missile Base SL-40, Underground Storage Magazines & Launcher-Loader Assemblies, Southwesternmost end of launch area, Hecker, Monroe County, IL

  11. Weather support area, floor plan and details. ("Alter COC, Bldg. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Weather support area, floor plan and details. ("Alter COC, Bldg. 2605, Weather Support Area, Floor Plan & Details" Also includes a site plan and a finish schedule. The exact location of this construction is obscure, but it appears to be the enclosure of space at the north end of room 101, the "Display Area" or "War Room") Strategic Air Command, Civil Engineering. Drawing no. B-1081, sheet no. 1 of 2, 9 July 1968; project no. MAR-132-8; CE-562; file drawer 2605-9, also 1315. Various scales. 29x41 inches. pencil on paper - March Air Force Base, Strategic Air Command, Combat Operations Center, 5220 Riverside Drive, Moreno Valley, Riverside County, CA

  12. 76 FR 31647 - Joint Industry Plan; Notice of Filing of a National Market System Plan to Address Extraordinary...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-01

    ... publication of the Commission's order approving the proposed Plan in the Federal Register. D. Development and..., Illinois 60605 (5) EDGA Exchange, Inc., 545 Washington Boulevard, Sixth Floor, Jersey City, NJ 07310 (6) EDGX Exchange, Inc., 545 Washington Boulevard, Sixth Floor, Jersey City, NJ 07310 (7) Financial...

  13. PBF Control Building (PER619) floor plan and elevations. Room numbers ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    PBF Control Building (PER-619) floor plan and elevations. Room numbers and functions. Roof plans for "high" roof and rest of roof. Ebasco Services 1205-PER/PER 619-A-1. Date: July 1965. INEEL index no. 760-0619-00-205-123022 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID

  14. 13. Architectural First Floor Plan Buildings 185189 D, U.S. Atomic ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    13. Architectural First Floor Plan Buildings 185-189 D, U.S. Atomic Energy Commission, General Electric Company, Dwg. NO. H-1-11825, 1959. - D-Reactor Complex, Deaeration Plant-Refrigeration Buildings, Area 100-D, Richland, Benton County, WA

  15. 12. Architectural Floor Plans, 233S, U.S. Atomic Energy Commission, Hanford ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    12. Architectural Floor Plans, 233-S, U.S. Atomic Energy Commission, Hanford Atomic Products Operations, General Electric Company, Dwg. H-2-30464, 1956. - Reduction-Oxidation Complex, Plutonium Concentration Facility, 200 West Area, Richland, Benton County, WA

  16. Photographic copy of floor plan, undated, Civil Engineers Office, in ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photographic copy of floor plan, undated, Civil Engineers Office, in possession of Selfridge Base Civil Engineers Office, Mt. Clemens, Michigan - Selfridge Field, Building No. 833, West of Mulberry Street north of George Avenue, Mount Clemens, Macomb County, MI

  17. 10. Historic American Buildings Survey Photocopy of Unsigned, Undated Drawing, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey Photocopy of Unsigned, Undated Drawing, Courtesy, The Cosmos Club PROPOSED FLOOR PLANS, 2121 MASSACHUSETTS AVENUE, N.W., BLUEPRINT #11, THIRD FLOOR PLAN - Townsend House, 2121 Massachusetts Avenue Northwest, Washington, District of Columbia, DC

  18. 11. Historic American Buildings Survey Photocopy of Unsigned, Undated Drawing, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. Historic American Buildings Survey Photocopy of Unsigned, Undated Drawing, Courtesy, The Cosmos Club PROPOSED FLOOR PLANS, 2121 MASSACHUSETTS AVENUE, N.W., BLUEPRINT #11, FOURTH FLOOR PLAN - Townsend House, 2121 Massachusetts Avenue Northwest, Washington, District of Columbia, DC

  19. 9. Historic American Buildings Survey Photocopy of Unsigned, Undated Drawing, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. Historic American Buildings Survey Photocopy of Unsigned, Undated Drawing, Courtesy, The Cosmos Club PROPOSED FLOOR PLANS, 2121 MASSACHUSETTS AVENUE, N.W., BLUEPRING #11, SECOND FLOOR PLAN - Townsend House, 2121 Massachusetts Avenue Northwest, Washington, District of Columbia, DC

  20. 8. Historic American Buildings Survey Photocopy of Unsigned, Undated Drawing, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. Historic American Buildings Survey Photocopy of Unsigned, Undated Drawing, Courtesy, The Cosmos Club PROPOSED FLOOR PLANS, 2121 MASSACHUSETTS AVENUE, N.W., BLUEPRINT #11, FIRST-FLOOR PLAN - Townsend House, 2121 Massachusetts Avenue Northwest, Washington, District of Columbia, DC

  1. ETR, TRA642 AND TRA647. FLOOR PLANS FOR FIRST AND SECOND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    ETR, TRA-642 AND TRA-647. FLOOR PLANS FOR FIRST AND SECOND FLOORS OF THE OFFICE AND CONTROL BUILDING ALONG THE NORTH WALL OF THE ETR BUILDING. HEALTH PHYSICS, OPERATIONS, AND CONTROL ROOM. AIRLOCK DOOR. OFFICES. STAIRWAY LOCATIONS. KAISER ETR-5528-MTR-642-A-3, 10/1955. INL INDEX NO. 532-0642-00-100911, REV. 0. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  2. HOT CELL BUILDING, TRA632. FLOOR PLAN OF EXPANSION SHOWS LOCATION ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    HOT CELL BUILDING, TRA-632. FLOOR PLAN OF EXPANSION SHOWS LOCATION OF NEW CELLS, "HEAVY" CELL AT WEST END, "LIGHT" CELLS AT EAST. MOCK-UP AND STORAGE AREAS IN SOUTH HALF OF FLOOR. H.K. FERGUSON 895-MTR-ETR-632-A1, 12/1958. INL INDEX NO. 531-0632-00-279-101924, REV. 4. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  3. PROCESS WATER BUILDING, TRA605. FLOOR AND ROOF PLANS FOR SECOND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    PROCESS WATER BUILDING, TRA-605. FLOOR AND ROOF PLANS FOR SECOND FLOOR. DETAILS OF CONCRETE ROOF SLABS. FLASH EVAPORATOR SUPPORTS AND PIPE OPENINGS TO TANKS BELOW. NOTE SPECIFIES THAT EQUIPMENT IS TO BE INSTALLED BEFORE ERECTION OF ROOF AND WALLS. BLAW-KNOX 3150-805-4, 1/1951. INL INDEX NO. 531-0605-62-098-100660, REV. 2. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  4. Library Survival. Workbook in Library Skills: A Self-Directed Course in the Use of the Marriott Library. General Studies 101.

    ERIC Educational Resources Information Center

    Gittins, Gwen; Dusenbury, Carolyn

    Designed to acquaint undergraduate students at the University of Utah with basic library resources and materials, the program of instruction presented can be used as a self-paced tool either in course related instruction or as an independent offering. A section containing floor plans of the University's Marriott Library illustrates the location of…

  5. 120. Back side technical facilities S.R. radar transmitter & computer ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    120. Back side technical facilities S.R. radar transmitter & computer building no. 102, section II "foundation & first floor plan" - structural, AS-BLT AW 35-46-04, sheet 65, dated 23 January, 1961. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK

  6. Plan of the entresol (third floor) of the Masonic Temple, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Plan of the entresol (third floor) of the Masonic Temple, ca. 1872, showing the original layout of the Asylum of the Knights Templar and the original Grand Staircase ceiling design - Masonic Temple, 1 North Broad Street, Philadelphia, Philadelphia County, PA

  7. SPERTI Control Building (PER601) floor plan. Detail of cable inlet. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    SPERT-I Control Building (PER-601) floor plan. Detail of cable inlet. Idaho Operations Office. Date: February 1955. INEEL index no. 760-0601-00-396-109139 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID

  8. 37. Historic American Buildings Survey ORIGINAL DRAWING, SECOND FLOOR PLAN ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    37. Historic American Buildings Survey ORIGINAL DRAWING, SECOND FLOOR PLAN (FROM AN ORIGINAL IN THE OFFICE OF THE VICE PRESIDENT FOR DEVELOPMENT AND PHYSICAL PLANT, GEORGETOWN UNIVERSITY) - Georgetown University, Healy Building, Thirty-seventh & O Streets, Northwest, Washington, District of Columbia, DC

  9. 36. Historic American Buildings Survey ORIGINAL DRAWING, FIRST FLOOR PLAN ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    36. Historic American Buildings Survey ORIGINAL DRAWING, FIRST FLOOR PLAN (FROM AN ORIGINAL IN THE OFFICE OF THE VICE PRESIDENT FOR DEVELOPMENT AND PHYSICAL PLANT, GEORGETOWN UNIVERSITY) - Georgetown University, Healy Building, Thirty-seventh & O Streets, Northwest, Washington, District of Columbia, DC

  10. 38. Historic American Buildings Survey ORIGINAL DRAWING, THIRD FLOOR PLAN ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    38. Historic American Buildings Survey ORIGINAL DRAWING, THIRD FLOOR PLAN (FROM THE ORIGINAL IN THE FILES OF THE VICE PRESIDENT FOR DEVELOPMENT AND PHYSICAL PLANT, GEORGETOWN UNIVERSITY) - Georgetown University, Healy Building, Thirty-seventh & O Streets, Northwest, Washington, District of Columbia, DC

  11. Prevention of childbirth injuries to the pelvic floor.

    PubMed

    Heit, M; Mudd, K; Culligan, P

    2001-08-01

    The majority of childbirth injuries to the pelvic floor occur after the first vaginal delivery. Cesarean sections performed after the onset of labor may not protect the pelvic floor. Elective cesarean section is the only true primary prevention strategy for childbirth injuries to the pelvic floor. Alternative primary prevention strategies include elective cesarean section for women with nonmodifiable risks for childbirth injuries to the pelvic floor, antepartum pelvic floor exercises, or intrapartum pudendal nerve monitoring. Secondary prevention strategies must focus on modifying obstetric practices that predispose women to pelvic floor injury. These factors are best delineated for anal incontinence and include restrictive use of episiotomy, mediolateral episiotomy when necessary, spontaneous over forceps-assisted vaginal delivery, vacuum extraction over forceps delivery, and antepartum perineal massage. Finally, tertiary prevention strategies should address the mode of delivery made for women with childbirth injuries to the pelvic floor who desire future fertility.

  12. ADM. Fuel Pump House (TAN611). Elevations, floor plan. Drawing includes ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    ADM. Fuel Pump House (TAN-611). Elevations, floor plan. Drawing includes elevation and plans for "H.M." structures (Hose Storage?). Ralph M. Parsons 902-2-ANP-611-A 78 Date: December 1952. Approved by INEEL Classification Office for public release. INEEL index code no. 035-0611-00-693-106741 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  13. 31. FLOOR PLANS OF WASTE CALCINATION FACILITY. SHOWS ACCESS CORRIDOR ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    31. FLOOR PLANS OF WASTE CALCINATION FACILITY. SHOWS ACCESS CORRIDOR AT MEZZANINE AND LOWER LEVELS. INEEL DRAWING NUMBER 200-0633-00-287-106352. FLUOR NUMBER 5775-CPP-633-A-2. - Idaho National Engineering Laboratory, Old Waste Calcining Facility, Scoville, Butte County, ID

  14. ARCHITECTURAL FLOOR PLAN OF OPERATING AREA HOT PILOT PLANT (CPP640). ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    ARCHITECTURAL FLOOR PLAN OF OPERATING AREA HOT PILOT PLANT (CPP-640). INL DRAWING NUMBER 200-0640-00-279-111678. ALTERNATE ID NUMBER 8952-CPP-640-A-1. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID

  15. 14. FIRST FLOOR PLAN. MONOMOY POINT LT. STATION, MASS., SHOWING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    14. FIRST FLOOR PLAN. MONOMOY POINT LT. STATION, MASS., SHOWING PROPOSED ALTERATION AND IMPROVEMENT OF DWELLING. No. 1343. SHEET 1 of 5. July 1899. - Monomoy Point Light Station, Approximately 3500 feet Northeast Powder Hole Pond, Monomoy National Wildlife Refuge, Chatham, Barnstable County, MA

  16. 15. SECOND FLOOR PLAN. MONOMOY POINT LT. STATION, MASS., SHOWING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    15. SECOND FLOOR PLAN. MONOMOY POINT LT. STATION, MASS., SHOWING PROPOSED ALTERATION AND IMPROVEMENT OF DWELLING. No. 1343. SHEET 2 OF 5. July 1899. - Monomoy Point Light Station, Approximately 3500 feet Northeast Powder Hole Pond, Monomoy National Wildlife Refuge, Chatham, Barnstable County, MA

  17. 43. FLOOR PLAN OF POWER HOUSE, EXHIBIT L, SANTA ANA ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    43. FLOOR PLAN OF POWER HOUSE, EXHIBIT L, SANTA ANA RIVER NO. 2 PROJECT, APR. 30, 1945. SCE drawing no. 523643 (sheet no. 14; for filing with Federal Power Commission). - Santa Ana River Hydroelectric System, SAR-2 Powerhouse, Redlands, San Bernardino County, CA

  18. Distribution of maple strip flooring in 1969

    Treesearch

    William C. Miller; William C. Miller

    1971-01-01

    This paper is the second in a series on the residential and commercial hardwood flooring industry. Unlike the first paper in the series, which dealt with oak strip flooring industry, this paper analyzes several qualitative questions pertaining to the maple flooring industry. The next paper planned for this series will analyze quantitative as well as qualitative...

  19. Floor vibration evaluations for medical facilities

    NASA Astrophysics Data System (ADS)

    Himmel, Chad N.

    2003-10-01

    The structural floor design for new medical facilities is often selected early in the design phase and in renovation projects, the floor structure already exists. Because the floor structure can often have an influence on the location of vibration sensitive medical equipment and facilities, it is becoming necessary to identify the best locations for equipment and facilities early in the design process. Even though specific criteria for vibration-sensitive uses and equipment may not always be available early in the design phase, it should be possible to determine compatible floor structures for planned vibration-sensitive uses by comparing conceptual layouts with generic floor vibration criteria. Relatively simple evaluations of planned uses and generic criteria, combined with on-site vibration and noise measurements early in design phase, can significantly reduce future design problems and expense. Concepts of evaluation procedures and analyses will be presented in this paper. Generic floor vibration criteria and appropriate parameters to control resonant floor vibration and noise will be discussed for typical medical facilities and medical research facilities. Physical, economic, and logistical limitations that affect implementation will be discussed through case studies.

  20. 11. BUILDING 1: FIRST FLOOR (Center Section), WEST AND NORTH ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. BUILDING 1: FIRST FLOOR (Center Section), WEST AND NORTH WALLS, SHOWING TWO TIERS OF COLUMNS WITH SECOND FLOOR REMOVED - Boston Beer Company, 225-249 West Second Street, South Boston, Suffolk County, MA

  1. 30. FLOOR PLANS OF WASTE CALCINATION FACILITY. SHOWS LEVELS ABOVE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    30. FLOOR PLANS OF WASTE CALCINATION FACILITY. SHOWS LEVELS ABOVE GRADE AND AT LEVEL OF OPERATING CORRIDOR. INEEL DRAWING NUMBER 200-0633-00-287-106351. FLUOR NUMBER 5775-CPP-633-A-1. - Idaho National Engineering Laboratory, Old Waste Calcining Facility, Scoville, Butte County, ID

  2. ARCHITECTURAL FLOOR PLAN OF PROCESS AND ACCESS AREAS HOT PILOT ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    ARCHITECTURAL FLOOR PLAN OF PROCESS AND ACCESS AREAS HOT PILOT PLANT (CPP-640). INL DRAWING NUMBER 200-0640-00-279-111679. ALTERNATE ID NUMBER 8952-CPP-640-A-2. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID

  3. 18. EXISTING FIRST FLOOR PLAN. MONOMOY POINT LT. STATION, MASS., ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    18. EXISTING FIRST FLOOR PLAN. MONOMOY POINT LT. STATION, MASS., SHOWING PROPOSED ALTERATION AND IMPROVEMENT OF DWELLING. No. 1343. Sheet 5 of 5. July 1899. - Monomoy Point Light Station, Approximately 3500 feet Northeast Powder Hole Pond, Monomoy National Wildlife Refuge, Chatham, Barnstable County, MA

  4. 9. First floor plan,published in 'Architectural Record',Vol 31,No. 4, April ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. First floor plan,published in 'Architectural Record',Vol 31,No. 4, April 1912,p 356,courtesy of the Art Institute of Chicago,permission to duplicate courtesy of'Architectural Record' - Chicago City Hall, 121 North LaSalle Street, Chicago, Cook County, IL

  5. 10. Fifth floor plan,published in 'Architectural Record',Vol 31,No. 4, April ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Fifth floor plan,published in 'Architectural Record',Vol 31,No. 4, April 1912,p. 356 (?),courtesy of Art Institute of Chicago, permission to duplicate courtesy of 'Architectural Record' - Chicago City Hall, 121 North LaSalle Street, Chicago, Cook County, IL

  6. 1. FLOOR PLANS (from sheet of drawings titled 'Alterations for ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. FLOOR PLANS (from sheet of drawings titled 'Alterations for Miss Alice Lee, San Diego California, 1911.' Original in the Art Galleries, University of California, Santa Barbara. Copied for the HABS Collection, 1975) - Alice Lee House, 3578 Seventh Avenue, San Diego, San Diego County, CA

  7. 7. Photographic copy of floor plan sketch, undated, Selfridge Air ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. Photographic copy of floor plan sketch, undated, Selfridge Air National Guard Base Civil Engineers Office in possession of Selfridge Base Civil Engineers Office, Mt. Clemens, Michigan. - Selfridge Field, Building No. 1514, Schoolhouse Road north of South Perimeter Road, Mount Clemens, Macomb County, MI

  8. 4. This photographic copy of an engineering drawing shows the ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. This photographic copy of an engineering drawing shows the plan and details for Test Stand "G" and the placement of the vibrator. California Institute of Technology, Jet Propulsion Laboratory, Plant Engineering: "Vibration Test Facility-Bldg E-72, Floor & Roof Plans, Sections, Details & Door Schedule," drawing no. E72/2-5, 21 May 1964. California Institute of Technology, Jet Propulsion Laboratory, Plant Engineering: engineering drawings of structures at JPL Edwards Facility. Drawings on file at JPL Plant Engineering, Pasadena, California. - Jet Propulsion Laboratory Edwards Facility, Test Stand G, Edwards Air Force Base, Boron, Kern County, CA

  9. 5. EAST SECTION OF BUILDING, FIRST FLOOR, WEST ROOM. NOTE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. EAST SECTION OF BUILDING, FIRST FLOOR, WEST ROOM. NOTE OVEN AT LEFT. All construction original except wood flooring, plumbing and electricity. - Ralph Izard House, Kitchen Building, 110 Broad Street, Charleston, Charleston County, SC

  10. Impact evaluation of composite floor sections

    NASA Technical Reports Server (NTRS)

    Boitnott, Richard L.; Fasanella, Edwin L.

    1989-01-01

    Graphite-epoxy floor sections representative of aircraft fuselage construction were statically and dynamically tested to evaluate their response to crash loadings. These floor sections were fabricated using a frame-stringer design typical of present aluminum aircraft without features to enhance crashworthiness. The floor sections were tested as part of a systematic research program developed to study the impact response of composite components of increasing complexity. The ultimate goal of the research program is to develop crashworthy design features for future composite aircraft. Initially, individual frames of six-foot diameter were tested both statically and dynamically. The frames were then used to construct built-up floor sections for dynamic tests at impact velocities of approximately 20 feet/sec to simulate survivable crash velocities. In addition, static tests were conducted to gain a better understanding of the failure mechanisms seen in the dynamic tests.

  11. LOFT, TAN650. Service building preamp tower, top three floors. Floor ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    LOFT, TAN-650. Service building pre-amp tower, top three floors. Floor plan, cable mazes, duct labyrinth. Borated water tank enclosure on roof. Kaiser engineers 6413-11-STEP/LOFT-650-A-3. Date: October 1964. INEEL index code no. 036-650-00-486-122215 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  12. 7. Photographic copy of floor plan drawing, dated August 10, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. Photographic copy of floor plan drawing, dated August 10, 1968, Department of the Air Force Air Defense Command Installations, in possession of Selfridge Base Museum, Mt. Clemens, Michigan. - Selfridge Field, Building No. 592, South of East Joy Boulevard, west of Taxiway C, Mount Clemens, Macomb County, MI

  13. 6. Photographic copy of floor plan, dated August 10, 1968, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. Photographic copy of floor plan, dated August 10, 1968, Department of the Air Force Air Defense Command Installation, in possession of Selfridge Base Museum, Mt. Clemens, Michigan. - Selfridge Field, Building No. 1576, South of East Joy Boulevard, west of Taxiway C, Mount Clemens, Macomb County, MI

  14. Photographic copy of floor plan drawing, dated August 10, 1968, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photographic copy of floor plan drawing, dated August 10, 1968, Department of the Air Force Air Defense Command Installations, in possession of Selfridge Base Museum, Mt. Clemens, Michigan - Selfridge Field, Building No. 1580, South of East Joy Boulevard, west of Taxiway C, Mount Clemens, Macomb County, MI

  15. FIRST FLOOR PLAN OF REMOTE ANALYTICAL FACILITY (CPP627) SHOWING REMOTE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FIRST FLOOR PLAN OF REMOTE ANALYTICAL FACILITY (CPP-627) SHOWING REMOTE ANALYTICAL LABORATORY, DECONTAMINATION ROOM, AND MULTICURIE CELL ROOM. INL DRAWING NUMBER 200-0627-00-008-105065. ALTERNATE ID NUMBER 4272-14-102. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID

  16. 6. 1859 sketch of the hospital's ground floor plan, before ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. 1859 sketch of the hospital's ground floor plan, before construction commenced in 1860. Photocopied from Report of the Board of Managers of the Hospital of the Protestant Episcopal Church, 1859 - Hospital of Protestant Episcopal Church in Philadelphia, Front Street & Lehigh Avenue, Philadelphia, Philadelphia County, PA

  17. GUARD HOUSE AND BARRACKS; SECOND FLOOR PLAN AND DOOR FRAME ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    GUARD HOUSE AND BARRACKS; SECOND FLOOR PLAN AND DOOR FRAME AND WINDOW DETAILS. Navy Department, Bureau of Yards & Docks, Navy Yard, Mar Island, CA. Albert F. Roller, Architect, San Francisco, CA. H.J. Brunnier, Structural Engineer, Sharon Building, San Francisco, CA. Sheet 2 of 15, accompanying specification Noy-4675. Submitted May 8, 1941, last revised July 14, 1941. Yards & Docks drawing no. 160687; P.W. (Public Works) drawing no. 10388-26; file no. 930-CR-4. Scale one eighth inch to one foot (floor plan) and 3 inches to one foot (details). 73 cm x 129 cm. Ink on vellum - Mare Island Naval Shipyard, Guard House & Barracks, Railroad Avenue near Eighteenth Street, Vallejo, Solano County, CA

  18. 26. Photographic copy of Second Floor Plan (The Ballinger Company, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    26. Photographic copy of Second Floor Plan (The Ballinger Company, April 12, 1955), In files of the City of Philadelphia. Division of Aviation, Terminal E. Philadelphia International Airport. Reprinted with permission of Division of Aviation. - TWA Maintenance Hangar, South side of Tinicum Island Road, Philadelphia International Airport, Philadelphia, Philadelphia County, PA

  19. 25. Photographic copy of First Floor Plan (The Ballinger Company, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    25. Photographic copy of First Floor Plan (The Ballinger Company, April 12, 1955). In files of the City of Philadelphia, Division of Aviation, Terminal E, Philadelphia International Airport. Reprinted with permission of the Division of Aviation. - TWA Maintenance Hangar, South side of Tinicum Island Road, Philadelphia International Airport, Philadelphia, Philadelphia County, PA

  20. SAFETY AND SECURITY BUILDING, TRA614. FLOOR, ROOF, AND FOUNDATION PLANS. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    SAFETY AND SECURITY BUILDING, TRA-614. FLOOR, ROOF, AND FOUNDATION PLANS. ROOM FUNCTIONS. DOOR AND ROOM FINISH SCHEDULE. BLAW-KNOX 3150-814-1, 3/1950. INL INDEX NO. 531-0614-00-098-100702, REV. 6. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  1. LPT. EBOR (TAN646). Floor plan for new helium management wing. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    LPT. EBOR (TAN-646). Floor plan for new helium management wing. Detail of sample vault and basement switch room. Kaiser engineers EBOR/GA-646-A-101. Date: May 1963. INEEL index code no. 037-0646-00-486-119115 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  2. ADM. Service Building (TAN603). Floor plan. Names of functional areas. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    ADM. Service Building (TAN-603). Floor plan. Names of functional areas. Ralph M. Parsons 902-2-ANY-603-A 43. Date: December 1952. Approved by INEEL Classification Office for public release. INEEL index code no. 033-0603-00-693-106718 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  3. ADM. Change House (TAN606). Elevations and floor plan. Room Names. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    ADM. Change House (TAN-606). Elevations and floor plan. Room Names. Ralph M. Parsons 902-2-ANP-606-A 65. Date: December 1952. Approved by INEEL Classification Office for public release. INEEL index code no. 035-0606-00-693-106733 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  4. ADM. Warehouse (TAN604) Floor plan. General warehouse and chemical storage. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    ADM. Warehouse (TAN-604) Floor plan. General warehouse and chemical storage. Ralph M. Parsons 902-2-ANP-604-A 55. Date: December 1952. Approved by INEEL Classification Office for public release. INEEL index code no. 035-0604-00-693-106727 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  5. Building Trades. Block III. Floor Framing.

    ERIC Educational Resources Information Center

    Texas A and M Univ., College Station. Vocational Instructional Services.

    This document contains three units of a course on floor framing to be used as part of a building trades program. Each unit consists, first, of an informational lesson, with complete lesson plan for the teacher's use. Included in each lesson plan are the lesson aim; lists of teaching aids, materials, references, and prerequisites for students;…

  6. FLOOR PLAN OF MAIN PROCESSING BUILDING (CPP601) BASEMENT SHOWING PROCESS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FLOOR PLAN OF MAIN PROCESSING BUILDING (CPP-601) BASEMENT SHOWING PROCESS CORRIDOR AND EIGHTEEN CELLS. TO LEFT IS LABORATORY BUILDING (CPP-602). INL DRAWING NUMBER 200-0601-00-706-051981. ALTERNATE ID NUMBER CPP-E-1981. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID

  7. SECOND FLOOR PLAN OF REMOTE ANALYTICAL FACILITY (CPP627) WARM LABORATORY ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    SECOND FLOOR PLAN OF REMOTE ANALYTICAL FACILITY (CPP-627) WARM LABORATORY ROOM, DECONTAMINATION ROOM, HOT CHEMISTRY LABORATORY, AND MULTICURIE CELL ROOM. INL DRAWING NUMBER 200-0627-00-098-105066. ALTERNATE ID NUMBER 4272-14-103. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID

  8. 16. Photocopy of drawing, floor system plan, Bridge No. 79B, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    16. Photocopy of drawing, floor system plan, Bridge No. 79B, Main & Washington Sts., So. Norwalk, Ct., N. Y. Division, N.Y., N.H. and H.R.R., dated April 23, 1895. Original on file with Metro North Commuter Railroad. - South Norwalk Railroad Bridge, South Main & Washington Streets, Norwalk, Fairfield County, CT

  9. LOFT. Containment and service building (TAN650) basement floor plan. Basement ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    LOFT. Containment and service building (TAN-650) basement floor plan. Basement airlock, shielded roadway, service areas, connection to control building. Kaiser engineers 6413-11-STEP/LOFT-650-A-1. Date: October 1964. INEEL index code no. 036-650-00-416-122213 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  10. A&M. Technical service laboratory in administration building (TAN602). Floor plan, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    A&M. Technical service laboratory in administration building (TAN-602). Floor plan, reception desk, door and finish schedules. Ralph M. Parsons 1480-12-ANP/GE-3-602-A-1. INEEL index code no. 033-0602-00-693-107488 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  11. 36. AS BUILT DRAWING OF TAN 629 HANGAR SHOWING FLOOR ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    36. AS BUILT DRAWING OF TAN 629 HANGAR SHOWING FLOOR PLAN AND VICINITY PLAN RELATIONSHIP TO ADMINISTRATION AND MAINTENANCE AREA. RALPH M. PARSONS DRAWING NUMBER: 1229-2 ANP/GE 5-629-A-2. DATED MARCH 15, 1957. - Idaho National Engineering Laboratory, Test Area North, Hangar No. 629, Scoville, Butte County, ID

  12. Floor Plans Engine Removal Platform, Hold Down Arm Platform, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Floor Plans - Engine Removal Platform, Hold Down Arm Platform, Hydraulic Equipment Platforms, Isometric Cutaway of Engine Removal Platform, Isometric Cutaway of Hold Down Arm Platform, Isometric Cutaway of Hydraulic Platforms and Engine Support System Access - Marshall Space Flight Center, Saturn V S-IC Static Test Facility, West Test Area, Huntsville, Madison County, AL

  13. FloorPlan. Courseware Evaluation for Vocational and Technical Education.

    ERIC Educational Resources Information Center

    Rosenfeld, Vila M.; And Others

    This courseware evaluation rates the "FloorPlan" program developed by the Learning Seed. (The program--not included in this document--allows room design and arrangement to be performed on the computer screen.) The courseware was rated by a team of home economists participating in a network for the dissemination of courseware reviews.…

  14. 45. Master plan of 4th floor, building 1, U.S. Naval ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    45. Master plan of 4th floor, building 1, U.S. Naval supply activities, New York, Brooklyn, New York, public works department, March 2, 1953. Drawing #BK-S1-4. Scale 1/16=1. - U.S. Navy Fleet Supply Base, Storehouse No. 1, 830 Third Avenue, Brooklyn, Kings County, NY

  15. Dose rate evaluation of workers on the operation floor in Fukushima-Daiichi Unit 3

    NASA Astrophysics Data System (ADS)

    Matsushita, Kaoru; Kurosawa, Masahiko; Shirai, Keisuke; Matsuoka, Ippei; Mukaida, Naoki

    2017-09-01

    At Fukushima Daiichi Nuclear Power Plant Unit 3, installation of a fuel handling machine is planned to support the removal of spent fuel. The dose rates at the workplace were calculated based on the source distribution measured using a collimator in order to confirm that the dose rates on the operation floor were within a manageable range. It was confirmed that the accuracy of the source distribution was C/M = 1.0-2.4. These dose rates were then used to plan the work on the operation floor.

  16. LPT. Shield test facility (TAN645 and 646). Floor plan and ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    LPT. Shield test facility (TAN-645 and -646). Floor plan and room names. Ralph M. Parsons 1229-17 ANP/GE-6-645-A-1. April 1957. Approved by INEEL Classification Office for public release. INEEL index code no. 037-0645/0646-00-693-107347 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  17. A&M. Demineralization plant, TAN649. Floor plan, elevation details. Ralph M. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    A&M. Demineralization plant, TAN-649. Floor plan, elevation details. Ralph M. Parsons 1480-4-ANP/GE-3-649-A-1. Date: October 1958. Approved by INEEL Classification Office for public release. INEEL index code no. 034-0649-00-693-107439 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  18. IET. Control and equipment building (TAN620) floor plan. Schedule of ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    IET. Control and equipment building (TAN-620) floor plan. Schedule of furniture and equipment. Ralph M. Parsons 902-4-ANP-A 320. Date: February 1954. Approved by INEEL Classification Office for public release. INEEL index code no. 035-0620-00-693-106905 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  19. Plan of the principal (second) floor of James H. Windrim ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Plan of the principal (second) floor of James H. Windrim and George Summers’s competition design for the New Masonic Temple, Philadelphia, 1867. The exterior wall outline of the architects’ Early Norman alternative design is shown overlaid across the left third of the drawing. - Masonic Temple, 1 North Broad Street, Philadelphia, Philadelphia County, PA

  20. MTR WING, TRA604. BASEMENT FLOOR PLAN. FIREPROOF RECORD ROOM BELOW ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    MTR WING, TRA-604. BASEMENT FLOOR PLAN. FIRE-PROOF RECORD ROOM BELOW COUNTING ROOM. HEATING AND COOLING EQUIPMENT. UNSPECIFIED EXPANSION AREA ALONG WEST WALL. BLAW-KNOX 3150-4-1, 7/1950. INL INDEX NO. 531-0604-00-098-100007, REV. 1. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  1. 43. 'Firing Pier, Third and Fourth Floors and Roof Plan,' ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    43. 'Firing Pier, Third and Fourth Floors and Roof Plan,' submitted 29 December 1941 by John Brackett, Consulting Engineer, to Public Works Department, Bureau of Yards & Docks. PW Drawing 3869-46, Y&D Drawing 190843. Scale 1/4' = 1'. - Naval Torpedo Station, Firing Pier, North end of Gould Island in Narragansett Bay, Newport, Newport County, RI

  2. 138. ARAII Building ARA606 floor plan for remodel as Inel ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    138. ARA-II Building ARA-606 floor plan for remodel as Inel Welding Laboratory. Shows room divisions and welding stations to be installed. Aerojet Nuclear Company 1375-ARA-II-606-E-2. Date: June 1976. Ineel index code no. 070-0606-10-400-156552. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID

  3. Impact of Distance to Treatment Center on Care Seeking for Pelvic Floor Disorders.

    PubMed

    English, Emily; Rogo-Gupta, Lisa

    The aim of this study was to evaluate the impact of distance from residence to treatment center on access to care for female pelvic floor disorders at an academic institution. A retrospective cross-sectional study was conducted of women seen for pelvic floor disorders at an academic institution from 2008 to 2014. Patient characteristics were extracted from charts. Geographical and US census data was obtained from public records and used to calculate distance from patient residence to physician office. Statistical analysis was performed using R Software (Version 0.98.1102) and Microsoft Excel (Version 14.4.7). Statistical significance was defined as a 2-sided P value of less than 0.05, and the χ test was used to determine associations of categorical variables. A total of 3015 patients were included in the analysis. The mean distance traveled was 93 miles. Thirty percent of patients traveled more than 50 miles. Many patients (43%) reported having the symptoms for more than 2 years. Patients who traveled farther were significantly more likely to be white, English-speaking, and with pelvic organ prolapse as primary complaint. These patients were more likely to plan surgery at the first visit than patients who traveled less far (29% vs 14%). Patients who traveled farther were also more likely to live in counties with a low percentage of persons older than 65 years and low percentage of female inhabitants. Women who travel the farthest for treatment of pelvic floor disorders have experienced the symptoms for longer duration and are more willing to plan surgery at presentation. These women also come from counties with fewer elderly women, suggesting future outreach care should focus on similar geographic areas.

  4. A Novel Method of Orbital Floor Reconstruction Using Virtual Planning, 3-Dimensional Printing, and Autologous Bone.

    PubMed

    Vehmeijer, Maarten; van Eijnatten, Maureen; Liberton, Niels; Wolff, Jan

    2016-08-01

    Fractures of the orbital floor are often a result of traffic accidents or interpersonal violence. To date, numerous materials and methods have been used to reconstruct the orbital floor. However, simple and cost-effective 3-dimensional (3D) printing technologies for the treatment of orbital floor fractures are still sought. This study describes a simple, precise, cost-effective method of treating orbital fractures using 3D printing technologies in combination with autologous bone. Enophthalmos and diplopia developed in a 64-year-old female patient with an orbital floor fracture. A virtual 3D model of the fracture site was generated from computed tomography images of the patient. The fracture was virtually closed using spline interpolation. Furthermore, a virtual individualized mold of the defect site was created, which was manufactured using an inkjet printer. The tangible mold was subsequently used during surgery to sculpture an individualized autologous orbital floor implant. Virtual reconstruction of the orbital floor and the resulting mold enhanced the overall accuracy and efficiency of the surgical procedure. The sculptured autologous orbital floor implant showed an excellent fit in vivo. The combination of virtual planning and 3D printing offers an accurate and cost-effective treatment method for orbital floor fractures. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  5. [Prevent postnatal urinary incontinence by prenatal pelvic floor exercise? Rationale and protocol of the multicenter randomized study PreNatal Pelvic floor Prevention (3PN)].

    PubMed

    Fritel, X; Fauconnier, A; de Tayrac, R; Amblard, J; Cotte, L; Fernandez, H

    2008-09-01

    Female urinary incontinence (UI) is a frequent affection that generates handicap and expenses. There is a link between UI and pregnancy; onset of UI during pregnancy is a risk factor for permanent UI. Postnatal pelvic floor exercise has shown efficacy to improve postnatal UI. However, it remains uncertain if benefits last more than few months. Publication of our rationale for prenatal pelvic floor exercise is an opportunity to expose our pre-specified hypotheses and help health professionals' awareness. The purpose of PreNatal Pelvic floor Prevention (3PN) is to compare the effects of prenatal pelvic floor exercise versus sole written instructions on UI one year after delivery. It is a multicenter, randomized, single blind study. Main inclusion criteria are first, single and non-complicated pregnancy over 18 years. Women randomized in pelvic floor exercise group will undergo eight sessions with a physiotherapist between six and eight months of pregnancy. Our principal criterion is UI score (International Consultation on Incontinence Questionnaire Short Form [ICIQ-SF]) one year after delivery. We plan to include 280 pregnant women in five centers over a 12-month screening period to show a one-point difference on UI score. ETHIC AND FINANCING: The study was approved by the IRB Comité de protection des personnes Sud-Ouest et Outre-Mer. It was registered by French Health Products Safety Agency (AFSSAPS) and Clinical Trials.gov. It is supported by the French Ministry of Health through the 2007 Hospital Plan for Clinical Research (PHRC). We plan to assess if prenatal pelvic floor exercise reduces postnatal medical consultations or physiotherapy sessions.

  6. Equipment Location Plan, partial first floor plan. (Includes identification of ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Equipment Location Plan, partial first floor plan. (Includes identification of each separate CPU, tape drive, hard drive, printer, keyboard, etc., within the data processing center in the southwest part of the first floor.) March Air Force Base, Riverside, California, Combat Operations Center, 465-L EDTCC/EDLCC. By International Electric Corporation, Paramus, New Jersey (3/5/62); for Moffatt and Nichol, Engineers, 122 West Fifth Street, Long Beach, California; for the Corps of Engineers, U.S. Army, Office of the District Engineer, Los Angeles, California. Drawing no. AW-60-02-03, sheet no. 85, approved March, 1962; specifications no. OCI-62-66; D.O. series AW 1596/85, Rev. "A"; file drawer 1290. Last revised 3 October 1966. Scale one-quarter inch to one foot. 28.75x40.5 inches. ink on linen - March Air Force Base, Strategic Air Command, Combat Operations Center, 5220 Riverside Drive, Moreno Valley, Riverside County, CA

  7. 19. Photocopy of Drawing (November 1934 Architectural Drawings by Burge ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    19. Photocopy of Drawing (November 1934 Architectural Drawings by Burge and Stevens, in Possession of the Engineering and Capital Improvements Department of the Atlanta Housing Authority, Atlanta, Georgia). FLOOR PLANS, TYPE 'A' APARTMENTS, FLOOR PLANS, TYPE 'B' APARTMENTS, KITCHEN ELEVATIONS, TECHWOOD PROJECT #1101, SHEET A-52. - Techwood Homes, Building No. 1, 575-579 Techwood Drive, Atlanta, Fulton County, GA

  8. FET. Control and equipment building (TAN630). Basement floor plan. Tunnel ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FET. Control and equipment building (TAN-630). Basement floor plan. Tunnel to hangar (TAN-629). Electrical and chemical services. Ralph M. Parsons 1229-2 ANP/GE-630-A-1. Date: March 1957. Approved by INEEL Classification Office for public release. INEEL index code no. 036-0630-00-693-107080 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  9. MTR WING, TRA604. FIRST FLOOR PLAN. ENTRY LOBBY, MACHINE SHOP, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    MTR WING, TRA-604. FIRST FLOOR PLAN. ENTRY LOBBY, MACHINE SHOP, INSTRUMENT SHOP, COUNTING ROOM, HEALTH PHYSICS LAB, LABS AND OFFICES, STORAGE, SHIPPING AND RECEIVING. BLAW-KNOX 3150-4-2, 7/1950. INL INDEX NO. 053-604-00-099-100008, REV. 7. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  10. FET. Control and equipment building, TAN630. Main floor plan. Control ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FET. Control and equipment building, TAN-630. Main floor plan. Control room. Room numbers and functions. Ralph M. Parsons. 1229-2-ANP/GE-5-630-A-2. Date: March 1957. Approved by INEEL Classification Office for public release. INEEL index code no. 036-0630-00-693-107081 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  11. A&M. TAN607. Foundation plan for hot shop floor and pool. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    A&M. TAN-607. Foundation plan for hot shop floor and pool. Tunnels to turntable. Motor pit. Ralph M. Parsons 902-3-ANP-607-S128. Date: December 1952. Approved by INEEL Classification Office for public release. INEEL index code no. 034-0607-62-693-160722 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  12. 148. ARAIII Reactor building (ARA608) Floor plan. Shows location of ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    148. ARA-III Reactor building (ARA-608) Floor plan. Shows location of reactor, heater, and mechanical loop pits; mechanical and electrical equipment rooms; and other work areas. Aerojet-general 880-area/GCRE-608-A-1. Date: February 1958. Ineel index code no. 063-0608-00-013-102612. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID

  13. 61. Photocopy of Engine Room Floor Plan, White Alder. The ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    61. Photocopy of Engine Room Floor Plan, White Alder. The Niagara Shipbuilding Corp. Engineering Department, Buffalo, New York. Coast Guard Headquarters Drawing No. 540-WAGL-1604-10, dated February 1943; revised January 1963. Original drawing property of the U.S. Coast Guard. - U.S. Coast Guard Cutter WHITE HEATH, USGS Integrated Support Command Boston, 427 Commercial Street, Boston, Suffolk County, MA

  14. Reducing Operating Costs by Optimizing Space in Facilities

    DTIC Science & Technology

    2012-03-01

    Base level 5 engineering units will provide facility floor plans, furniture layouts, and staffing documentation as necessary. One obstacle...due to the quantity and diverse locations. Base level engineering units provided facility floor plans, furniture layouts, and staffing documentation... furniture purchases and placement 5. Follow a quality systematic process in all decisions The per person costs can be better understood with a real

  15. A&M. TAN607 second floor plan for cold assembly area. Metallurgical ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    A&M. TAN-607 second floor plan for cold assembly area. Metallurgical lab, chemistry lab, nuclear instrument lab, equipment rooms. Ralph M. Parsons 902-ANP-607-A 102. Date: December 1952. Approved by INEEL Classification Office for public release. INEEL index code no. 034-0607-693-106754 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  16. 21. VIEW OF THE FIRST FLOOR PLAN. THE ORIGINAL DRAWING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    21. VIEW OF THE FIRST FLOOR PLAN. THE ORIGINAL DRAWING HAS BEEN ARCHIVED ON MICROFILM. THE DRAWING WAS REPRODUCED AT THE BEST QUALITY POSSIBLE. LETTERS AND NUMBERS IN THE CIRCLES INDICATE FOOTER AND/OR COLUMN LOCATIONS. - Rocky Flats Plant, Non-Nuclear Production Facility, South of Cottonwood Avenue, west of Seventh Avenue & east of Building 460, Golden, Jefferson County, CO

  17. MTRETR MAINTENANCE SHOP, TRA653. FLOOR PLAN FOR MEZZANINE: LUNCH AND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    MTR-ETR MAINTENANCE SHOP, TRA-653. FLOOR PLAN FOR MEZZANINE: LUNCH AND CONFERENCE ROOM, STORAGE AREA, OFFICES FOR FOREMEN, STENOS, ENGINEERS, DISPATCHER, WOMEN'S RESTROOM. HUMMEL HUMMEL & JONES 810-MTR-ETR-653-A-12, 2/1958. INL INDEX NO. 532-0653-00-381-102837, REV. 3. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  18. South elevation and main floor plan. San Bernardino Valley Union ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    South elevation and main floor plan. San Bernardino Valley Union Junior College, Science Building. Includes chemistry and botany departments. Howard E. Jones, Architect, San Bernardino, California. Sheet 2, job no. 311. Scale 1/8 inch to the foot. February 15, 1927. - San Bernardino Valley College, Life Science Building, 701 South Mount Vernon Avenue, San Bernardino, San Bernardino County, CA

  19. 91. Photographic copy of drawing (16 February 1905, reproduction of ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    91. Photographic copy of drawing (16 February 1905, reproduction of original drawing in Archives, Public Affairs Department, Sears Merchandise Group, Hoffman Estates, Illinois). Nimmons and Fellows. 1/16 inch to one foot. Plan dimensions are given on this floor plan of the first four bays of warehouse west of Homan Avenue. This drawing is excerpted from a blueprint set. FIRST FLOOR PLAN - Sears Roebuck & Company Mail Order Plant, Merchandise Building, 924 South Homan Avenue, Chicago, Cook County, IL

  20. This photocopy of an engineering drawing shows the floor plan ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    This photocopy of an engineering drawing shows the floor plan of the Liner Lab, including room functions. Austin, Field & Fry, Architects Engineers, 22311 West Third Street, Los Angeles 57, California: Edwards Test Station Complex Phase II, Jet Propulsion Laboratory, California Institute of Technology, Edwards Air Force Base, Edwards, California: "Liner Laboratory, Floor Plan and Schedules," drawing no. E33/4-2, 26 June 1962. California Institute of Technology, Jet Propulsion Laboratory, Plant Engineering: engineering drawings of structures at JPL Edwards Facility. Drawings on file at JPL Plant Engineering, Pasadena, California. California Institute of Technology, Jet Propulsion Laboratory, Plant Engineering: engineering drawings of structures at JPL Edwards Facility. Drawings on file at JPL Plant Engineering, Pasadena, California - Jet Propulsion Laboratory Edwards Facility, Liner Laboratory, Edwards Air Force Base, Boron, Kern County, CA

  1. Magnetic resonance imaging of pelvic floor dysfunction.

    PubMed

    Lalwani, Neeraj; Moshiri, Mariam; Lee, Jean H; Bhargava, Puneet; Dighe, Manjiri K

    2013-11-01

    Pelvic floor dysfunction is largely a complex problem of multiparous and postmenopausal women and is associated with pelvic floor or organ descent. Physical examination can underestimate the extent of the dysfunction and misdiagnose the disorders. Functional magnetic resonance (MR) imaging is emerging as a promising tool to evaluate the dynamics of the pelvic floor and use for surgical triage and operative planning. This article reviews the anatomy and pathology of pelvic floor dysfunction, typical imaging findings, and the current role of functional MR imaging. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. Nondestructive structural evaluation of wood floor systems with a vibration technique.

    Treesearch

    Xiping Wang; Robert J. Ross; Lawrence Andrew Soltis

    2002-01-01

    The objective of this study was to determine if transverse vibration methods could be used to effectively assess the structural integrity of wood floors as component systems. A total of 10 wood floor systems, including 3 laboratory-built floor sections and 7 in-place floors in historic buildings, were tested. A forced vibration method was applied to the floor systems...

  3. 28. Photocopy of 1921 architectural drawing titled: BUILDING 59, PATTERN ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    28. Photocopy of 1921 architectural drawing titled: BUILDING 59, PATTERN SHOP, PROPOSED EXTENSION SHOWING floor plans for the first and second floors, elevation detail of how the north extension would fit the existing building, and a plan view of site with adjacent buildings. Drawing No. 6167, File No. 651-23. - Puget Sound Naval Shipyard, Pattern Shop, Farragut Avenue, Bremerton, Kitsap County, WA

  4. Instrumentation and control building, architectural, floor plans. Specifications no. Eng043535572; ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Instrumentation and control building, architectural, floor plans. Specifications no. Eng-04-353-55-72; Drawing No. 60-09-12' sheet 64 of 148; file no. 1321/15. Stamped: record drawing - as constructed. Below stamp: Contract no. 4338, no change. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Control Center, Test Area 1-115, near Altair & Saturn Boulevards, Boron, Kern County, CA

  5. 143. ARAIII Control building (ARA607) Floor plan. Shows control room, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    143. ARA-III Control building (ARA-607) Floor plan. Shows control room, contaminated work area, counting and computer room, health physics room, instrument repair room, offices, and other rooms. Aerojet-general 880-area/GCRE-607-A-1. Date: February 1958. Ineel index code no. 063-0607-00-013-102546. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID

  6. LPT. Shield test facility (TAN646). Floor plan for water treatment ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    LPT. Shield test facility (TAN-646). Floor plan for water treatment room on west facade, tank and filter locations in basement along service tunnel and in coupling station. Ralph M. Parsons 1229-17 ANP/GE-6-646-P-2. April 1957. INEEL Index code no. 037-0645/0646-51-693-107387 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  7. MTR, TRA603. SECOND FLOOR PLAN. OFFICES AND INSTRUMENT ROOM. STEEL ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    MTR, TRA-603. SECOND FLOOR PLAN. OFFICES AND INSTRUMENT ROOM. STEEL PARTITIONS ON EAST SIDE OF INSTRUMENT ROOM. DETAIL OF COLUMN ENCASEMENTS. STAIRWAYS IN NORTH AND SOUTH CORNERS. PASSENGER ELEVATION. BLAW-KNOX 3150-803-3, 7/1950. INL INDEX NO. 531-0603-00-098-100562, REV. 6. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  8. 22. VIEW OF THE BASEMENT FLOOR PLAN. THE BASEMENT TUNNELS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    22. VIEW OF THE BASEMENT FLOOR PLAN. THE BASEMENT TUNNELS WERE DESIGNED AS FALLOUT SHELTERS AND USED FOR STORAGE. THE ORIGINAL DRAWING HAS BEEN ARCHIVED ON MICROFILM. THE DRAWING WAS REPRODUCED AT THE BEST QUALITY POSSIBLE. LETTERS AND NUMBERS IN THE CIRCLES INDICATE FOOTER AND/OR COLUMN LOCATIONS. - Rocky Flats Plant, General Manufacturing, Support, Records-Central Computing, Southern portion of Plant, Golden, Jefferson County, CO

  9. 75 FR 31482 - Self-Regulatory Organizations; NYSE Amex LLC; Notice of Filing and Immediate Effectiveness of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-03

    ... Rule Violation Plan. Background Effective October 1, 2008, NYSE Euronext, acquired the parent company... Floor, or use an Exchange issued and authorized portable phone, to communicate with non- members off the... authorized portable phone may communicate directly from the point of sale on the Floor with someone off-Floor...

  10. An exploration of the motivation of pregnant women to perform pelvic floor exercises using the revised theory of planned behaviour.

    PubMed

    Whitford, Heather M; Jones, Martyn

    2011-11-01

    To investigate the motivation of pregnant women towards the practice of pelvic floor exercises during pregnancy using the revised Theory of Planned Behaviour (RTPB), incorporating measures of past behaviour. Longitudinal cohort study. Women (n= 289) attending antenatal clinics in the North-East of Scotland were interviewed in the third trimester of pregnancy regarding their practice of pelvic floor exercises. Beliefs and attitudes about the exercises were investigated by self-administered questionnaire using the RTPB as a framework. A follow-up postal questionnaire was sent between 6 and 12 months after delivery. TPB variables (attitude, subjective norm, and self-efficacy) explained 53.1% of the variance in intention to practise pelvic floor exercises during pregnancy. Perceived vulnerability to incontinence (attitude to the current behaviour) had no relationship with intention. Measures of past behaviour significantly improved the percentage of explained variance in intention. Confidence in ability to perform pelvic floor exercises correctly (self-efficacy) reliably predicted subsequent practice. Future compliance with pelvic floor exercises may be enhanced by effective instruction to enhance confidence in ability to contract the correct muscles and promotion of measures to help establish a habit of exercising the pelvic floor muscles. ©2011 The British Psychological Society.

  11. Optimization of Typological Requirements for Low-Cost Detached Houses

    NASA Astrophysics Data System (ADS)

    Kuráň, Jozef

    2017-09-01

    The presented paper deals with an analysis of the legislative, hygienic, functional and operational requirements for the design of detached houses and individual dwellings in terms of typological requirements. The article also presents a sociological survey about the preferences and subjective requirements of relevant public group segments in terms of living in a detached house or an individual dwelling. The aim of the paper is to define the possibilities for the optimization of typological requirements. The optimization methods are based on principles already applied to contemporary detached house preferences and trends. The main idea is to reduce the amount of floor space, thus lowering construction and operating costs. The goal is to design an optimized floor plan, while preserving the hygienic criteria for individual residential dwellings. By applying optimization methods, a so-called rationalized and conditioned floor plan results in an individual dwelling floor plan design that can be compared to a reference model with an accurate quantification comparison. The significant sources of research are the legislative and normative requirements in the field of house construction in Slovakia, the Czech Republic and abroad.

  12. Structure-borne sound from magnetic resonance imaging systems

    NASA Astrophysics Data System (ADS)

    Ungar, Eric E.; Zapfe, Jeffrey A.

    2003-10-01

    Magnetic resonance imaging (MRI) systems are known to produce a considerable amount of audible noise. The recent tendency to install such systems on above-grade floors has led to increasing concerns about structure-borne noise transmission from the MRI to adjacent occupied areas. This paper presents the results of a study in which structure-borne noise forces produced by two operational MRI systems were determined via measurement of the floor vibrations induced by the systems and of the impedance of their supporting floors. Forces with known spectra were applied to the floors of planned MRI suites in a hospital extension and the corresponding noise in adjacent areas was measured. Similarly, airborne noise was introduced in the planned suites and the related noise in adjacent areas was measured. The results then were scaled to correspond to the measured MRI forces and airborne noise. It was found that in areas below the planned MRI installations structure-borne noise would predominate, unless it is mitigated. Structure-borne noise isolation of MRI systems, whose environments must meet stringent vibration criteria, is discussed briefly.

  13. 40 CFR 427.70 - Applicability; description of the asbestos floor tile subcategory.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... asbestos floor tile subcategory. 427.70 Section 427.70 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS ASBESTOS MANUFACTURING POINT SOURCE CATEGORY Asbestos Floor Tile Subcategory § 427.70 Applicability; description of the asbestos floor tile subcategory...

  14. 40 CFR 427.70 - Applicability; description of the asbestos floor tile subcategory.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... asbestos floor tile subcategory. 427.70 Section 427.70 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS (CONTINUED) ASBESTOS MANUFACTURING POINT SOURCE CATEGORY Asbestos Floor Tile Subcategory § 427.70 Applicability; description of the asbestos floor tile...

  15. 40 CFR 427.70 - Applicability; description of the asbestos floor tile subcategory.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... asbestos floor tile subcategory. 427.70 Section 427.70 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS ASBESTOS MANUFACTURING POINT SOURCE CATEGORY Asbestos Floor Tile Subcategory § 427.70 Applicability; description of the asbestos floor tile subcategory...

  16. 40 CFR 427.70 - Applicability; description of the asbestos floor tile subcategory.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... asbestos floor tile subcategory. 427.70 Section 427.70 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS (CONTINUED) ASBESTOS MANUFACTURING POINT SOURCE CATEGORY Asbestos Floor Tile Subcategory § 427.70 Applicability; description of the asbestos floor tile...

  17. 40 CFR 427.70 - Applicability; description of the asbestos floor tile subcategory.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... asbestos floor tile subcategory. 427.70 Section 427.70 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS (CONTINUED) ASBESTOS MANUFACTURING POINT SOURCE CATEGORY Asbestos Floor Tile Subcategory § 427.70 Applicability; description of the asbestos floor tile...

  18. A&M. TAN607 third floor plan for hot shop. Crane control ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    A&M. TAN-607 third floor plan for hot shop. Crane control rooms and their shielding windows. Plenum. Wall rack for manipulators in hot shop. Ralph M. Parsons 902-3-ANP-607-A 103. Date: December 1952. Approved by INEEL Classification Office for public release. INEEL index code no. 034-0607-00-693-106755 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  19. 8. "TEST STAND, ARCHITECTURAL, FLOOR PLANS AND SCHEDULES." Specifications No. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. "TEST STAND, ARCHITECTURAL, FLOOR PLANS AND SCHEDULES." Specifications No. ENG-04-353-55-72; Drawing No. 60-0912; sheet 22 of 148; file no. 1320/73. Stamped: RECORD DRAWING - AS CONSTRUCTED. Below stamp: Contract no. 4338, no change. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A Terminal Room, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  20. 22. VIEW OF THE BASEMENT AND MEZZANINE FLOOR PLANS. ALL ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    22. VIEW OF THE BASEMENT AND MEZZANINE FLOOR PLANS. ALL MECHANICAL AND ELECTRICAL UTILITY EQUIPMENT IS CONTAINED IN THE BASEMENT. THE MEZZANINE CONTAINS OFFICES. THE DRAWING WAS REPRODUCED AT THE BEST QUALITY POSSIBLE. LETTERS AND NUMBERS IN THE CIRCLES INDICATE FOOTER AND/OR COLUMN LOCATIONS. - Rocky Flats Plant, Non-Nuclear Production Facility, South of Cottonwood Avenue, west of Seventh Avenue & east of Building 460, Golden, Jefferson County, CO

  1. Maintenance of Vinyl Asbestos and Asphalt Tile Floors in Institutional, Industrial and Commercial Buildings.

    ERIC Educational Resources Information Center

    Asphalt and Vinyl Asbestos Tile Inst., New York, NY.

    The claim is made that proper planning and modest outlays of time, labor, and material costs can provide and maintain a high appearance level for floors in institutional, commercial, and industrial buildings. Instructions for four basic steps in maintaining the good looks of vinyl asbestos and asphalt tile floors are treated in the booklet--(1)…

  2. 22. INTERIOR, FIRST FLOOR, EAST SECTION, NORTHEAST ROOM, NORTHWEST CORNER ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    22. INTERIOR, FIRST FLOOR, EAST SECTION, NORTHEAST ROOM, NORTHWEST CORNER (NOTE EXPOSED BRICK NOGGING) - Peter Burr House, Vicinity of State Route 9 & Ridge Road, Shenandoah Junction, Jefferson County, WV

  3. 17. Truss suspended column, industrial loft building, looking at southeast ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    17. Truss suspended column, industrial loft building, looking at southeast corner. Note open floor plan as a result of the floor beams being suspended from above. - Dry Dock Engine Works, 1801 Atwater Street, Detroit, MI

  4. 49 CFR 38.79 - Floors, steps and thresholds.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false Floors, steps and thresholds. 38.79 Section 38.79... SPECIFICATIONS FOR TRANSPORTATION VEHICLES Light Rail Vehicles and Systems § 38.79 Floors, steps and thresholds. (a) Floor surfaces on aisles, step treads, places for standees, and areas where wheelchair and...

  5. 49 CFR 38.99 - Floors, steps and thresholds.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false Floors, steps and thresholds. 38.99 Section 38.99... SPECIFICATIONS FOR TRANSPORTATION VEHICLES Commuter Rail Cars and Systems § 38.99 Floors, steps and thresholds. (a) Floor surfaces on aisles, step treads, places for standees, and areas where wheelchair and...

  6. 49 CFR 38.117 - Floors, steps and thresholds.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false Floors, steps and thresholds. 38.117 Section 38...) ACCESSIBILITY SPECIFICATIONS FOR TRANSPORTATION VEHICLES Intercity Rail Cars and Systems § 38.117 Floors, steps and thresholds. (a) Floor surfaces on aisles, step treads and areas where wheelchair and mobility aid...

  7. 15. Interior view of first floor aisle in 1904 middle ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    15. Interior view of first floor aisle in 1904 middle section. Camera pointed south from near juncture with 1922 north section. - Puget Sound Naval Shipyard, Pattern Shop, Farragut Avenue, Bremerton, Kitsap County, WA

  8. Repair Air Conditioning, COC Bldg 2605, First Floor Plan. By ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Repair Air Conditioning, COC Bldg 2605, First Floor Plan. By Strategic Air Command, Civil Engineering. Drawing no. R-156, sheet no. 2 of 4, 15 August 1968; project no. MAR-125-8;CE-572; file drawer 2605-6. Scale one-eighth inch to one foot. 29x41 inches. pencil on paper 405 - March Air Force Base, Strategic Air Command, Combat Operations Center, 5220 Riverside Drive, Moreno Valley, Riverside County, CA

  9. A&M. TAN607 second floor plan for hot shop. Roof of ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    A&M. TAN-607 second floor plan for hot shop. Roof of pool. Viewing window locations. Special equipment room. This drawing was re-drawn to show conditions in 1994. Ralph M. Parsons 902-3-ANP-607-A 101. Date: December 1952. Approved by INEEL Classification Office for public release. INEEL index code no. 034-060-00-693-106753 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  10. LPT. Low power test (TAN640 and 641) floor plan. Cells ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    LPT. Low power test (TAN-640 and -641) floor plan. Cells 101 and 102, control rooms, shielded counting room, generator room, list of room numbers and names. Door details. Ralph M. Parsons 1229-12 ANP/GE-7-640-A-1. November 1956. Approved by INEEL Classification Office for public release. INEEL index code no. 038-0640-00-693-107274 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  11. 7. "CONTROL BUILDING; FLOOR PLAN, ELEVATIONS AND DETAILS." Specifications No. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. "CONTROL BUILDING; FLOOR PLAN, ELEVATIONS AND DETAILS." Specifications No. OC1-59-53; Drawing No. 5841-A-1; D.O. SERIES AW1525/2 Rev. B. Stamped: RECORD DRAWING AS CONSTRUCTED. Below stamp: Contract No. 5619, Rev. B. Date: 7-8-59. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Firing Control Building, Test Area 1-100, northeast end of Test Area 1-100 Road, Boron, Kern County, CA

  12. North elevation and second floor plan. San Bernardino Valley Union ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    North elevation and second floor plan. San Bernardino Valley Union Junior College, Science Building. Includes physics, geology, and zoology departments shelving. Howard E. Jones, Architect, San Bernardino, California. Sheet 4, job no. 311. Scales 1/8 inch to the foot (elevations) and 1/2 inch to the foot (shelving). February 15, 1927. - San Bernardino Valley College, Life Science Building, 701 South Mount Vernon Avenue, San Bernardino, San Bernardino County, CA

  13. Creating Library Interiors: Planning and Design Considerations.

    ERIC Educational Resources Information Center

    Jones, Plummer Alston, Jr.; Barton, Phillip K.

    1997-01-01

    Examines design considerations for public library interiors: access; acoustical treatment; assignable and nonassignable space; building interiors: ceilings, clocks, color, control, drinking fountains; exhibit space: slotwall display, floor coverings, floor loading, furniture, lighting, mechanical systems, public address, copying machines,…

  14. 10. BUILDING: SECOND FLOOR (East Section), VIEW SOUTH: EAST, SOUTH ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. BUILDING: SECOND FLOOR (East Section), VIEW SOUTH: EAST, SOUTH AND WEST WALLS OF COLD STORAGE, ALSO SHOWING REMNANTS OF COOLING PIPES - Boston Beer Company, 225-249 West Second Street, South Boston, Suffolk County, MA

  15. Photographic copy of floor plans for Bachelor Officers' Quarters (Tl) ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photographic copy of floor plans for Bachelor Officers' Quarters (T-l) known as the "Desert Rat Hotel" in the early days of the Muroc Flight Test Base (North Base). The plans show the layout of quarters, lavatories, mess as well as, the cooling system installation. Contract W-509-Eng 2937, Military Construction; Muroc Bombing Range, Muroc Lake, Calif; Materiel Test Site, Officers Quarters, Evaporative Coolers, Sheet 5 of 11, May 1942. Reproduced from the holdings of the National Archives, Pacific Southwest Region - Edwards Air Force Base, North Base, Bachelor Officers' Quarters T-1, Second & C Streets, Boron, Kern County, CA

  16. A&M. Hot cell addition (TAN633). Floor plan, elevations. Arrangement of ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    A&M. Hot cell addition (TAN-633). Floor plan, elevations. Arrangement of monorail along corridor, four hot cells, plug access openings, viewing windows, photo darkroom. Ralph M. Parsons 1229-13-ANP/GE-3-633-A-1. Date: December 1956 as redrawn in August 1998. Approved by INEEL Classification Office for public release. INEEL index code no. 034-0633-00-693-107315 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  17. 58. SECTION AND DETAILS OF FOURTH AND FIFTH FLOOR ADDITIONS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    58. SECTION AND DETAILS OF FOURTH AND FIFTH FLOOR ADDITIONS TO BUILDINGS NO. 2 AND 4, DATED JUNE 24, 1937; SCHMIDT, GARDEN AND ERICKSON, ARCHITECTS - Underwriters' Laboratories, 207-231 East Ohio Street, Chicago, Cook County, IL

  18. 15. BUILDING 1: FOURTH FLOOR (West Section), TOP LEVEL OF ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    15. BUILDING 1: FOURTH FLOOR (West Section), TOP LEVEL OF TUBS, SOUTH AND WEST WALLS. OPEN METAL BREWER'S STAIR VISIBLE ALONG WEST WALL - Boston Beer Company, 225-249 West Second Street, South Boston, Suffolk County, MA

  19. Constructing an Indoor Floor Plan Using Crowdsourcing Based on Magnetic Fingerprinting

    PubMed Central

    Zhao, Fang; Jiang, Mengling; Ma, Hao; Zhang, Yuexia

    2017-01-01

    A large number of indoor positioning systems have recently been developed to cater for various location-based services. Indoor maps are a prerequisite of such indoor positioning systems; however, indoor maps are currently non-existent for most indoor environments. Construction of an indoor map by external experts excludes quick deployment and prevents widespread utilization of indoor localization systems. Here, we propose an algorithm for the automatic construction of an indoor floor plan, together with a magnetic fingerprint map of unmapped buildings using crowdsourced smartphone data. For floor plan construction, our system combines the use of dead reckoning technology, an observation model with geomagnetic signals, and trajectory fusion based on an affinity propagation algorithm. To obtain the indoor paths, the magnetic trajectory data obtained through crowdsourcing were first clustered using dynamic time warping similarity criteria. The trajectories were inferred from odometry tracing, and those belonging to the same cluster in the magnetic trajectory domain were then fused. Fusing these data effectively eliminates the inherent tracking errors originating from noisy sensors; as a result, we obtained highly accurate indoor paths. One advantage of our system is that no additional hardware such as a laser rangefinder or wheel encoder is required. Experimental results demonstrate that our proposed algorithm successfully constructs indoor floor plans with 0.48 m accuracy, which could benefit location-based services which lack indoor maps. PMID:29156639

  20. Effect of different flooring systems on weight and pressure distribution on claws of dairy cows.

    PubMed

    Telezhenko, E; Bergsten, C; Magnusson, M; Ventorp, M; Nilsson, C

    2008-05-01

    Weight and pressure distribution on the claw were studied in Swedish Holsteins housed in different flooring systems. A total of 127 cows housed in different sections of the experimental barn were used. Each section had different flooring in the walking and standing areas. There were rubber mats or abrasive mastic asphalt flooring on the alleys or a low-abrasive slatted concrete floor. Some sections had feed-stalls equipped with rubber mats; other sections did not. The vertical ground reaction force, contact area, and average contact pressure were determined on the left hind foot using the I-Scan system and analyzed with the F-scan system. These determinations were made in each of the following 3 zones of the claw: bulb, wall, and sole. Most of the weight on claws exposed to concrete floors was carried by the bulb (37.4 +/- 3.5 and 18.3 +/- 2.9% of weight exerted on the foot in the lateral and medial claw, respectively) and the wall zone (20.0 +/- 2.6 and 13.4 +/- 2.4% on lateral and medial claw, respectively). The weight and pressure distribution in cows kept on sections with rubber covered alleys but passing daily over the asphalt floor on their way to the milking parlor did not differ in any zones, except for lateral bulbs, compared with those exposed to slatted concrete alone. Still, the weight bearing of the sole zone in cows kept on rubber mats without access to asphalt was less than that of cows kept on concrete slatted floors (5.1 +/- 0.7 vs. 12.7 +/- 1.1% and 1.1 +/- 0.5 vs. 8.7 +/- 0.7% in lateral and medial claws, respectively). In cows kept on asphalt flooring without feed-stalls, most weight was exerted to the sole zone (36.2 +/- 2.9 and 22.2 +/- 1.8% in lateral and medial claws, respectively). Feed-stalls in combination with asphalt flooring yielded a decreased total contact area (30.1 +/- 1.2 cm(2)) compared with asphalt floors without feed-stalls (35.7 +/- 1.2 cm(2)). The largest total contact area was obtained on the asphalt floor without feed-stalls, resulting in a lower contact pressure (39.8 +/- 2.3 N/cm(2)) than in claws exposed to concrete (66.0 +/- 2.7 N/ cm(2)) or rubber mats (56.7 +/- 1.7 N/cm(2)). In conclusion, housing with abrasive floors resulted in claws with increased contact area at the sole surface and therefore, decreased contact pressure, but reduced the weight-bearing role of the strongest part of the claw capsule, the claw wall.

  1. 123. Photographic copy of drawing (6 October 1916, original drawing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    123. Photographic copy of drawing (6 October 1916, original drawing in Archives, Office of the Building, Administration Building, Sears Roebuck and Company Mail Order Plant, Chicago, Illinois). Drawn by Sears Department 213 (engineer unknown). 1/16 inch to one foot. Partial fourth/fifth floor plan and schematic building section showing the relationship of the gravity conveyors in the warehouse space to the spiral chutes. GENERAL LAYOUT OF ALL MDSE DEPT. CONVEYORS - Sears Roebuck & Company Mail Order Plant, Merchandise Building, 924 South Homan Avenue, Chicago, Cook County, IL

  2. 9 CFR 91.26 - Concrete flooring.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    .... Flooring shall be laid athwartship and secured by placing ends beneath the under side of foot and rump... raised. The flush type shall be constructed of not less than 1″ thick lumber laid flat on the deck. The...″ dimensions laid 2 feet 6 inches apart. If desired, flooring may be laid in portable sections. Flooring will...

  3. 26. GRAINELEVATOR SECTION, SECOND FLOOR, INTERIOR, DETAIL OF GRAIN CRIB ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    26. GRAIN-ELEVATOR SECTION, SECOND FLOOR, INTERIOR, DETAIL OF GRAIN CRIB FRAMING; ELECTRICAL EQUIPMENT IS MOUNTED ON WHAT WAS ONCE THE INTERIOR OF BIN NUMBER NINE; LOOKING SOUTHEAST - Standard Mill, 116-118 Portland Avenue South, Minneapolis, Hennepin County, MN

  4. 7. Photocopy of measured drawing dated December, 1947 SECOND FLOOR ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. Photocopy of measured drawing dated December, 1947 SECOND FLOOR PLAN An addendum to Hanson-Cramer House, Sea Street, south end, Rockport, Knox County, Maine - Hanson-Cramer House, End of Sea Street (moved from Pascal's Avenue), Rockport, Knox County, ME

  5. 6. Photocopy of measured drawing dated December, 1947 FIRST FLOOR ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. Photocopy of measured drawing dated December, 1947 FIRST FLOOR PLAN An addendum to Hanson-Cramer House, Sea Street, south end, Rockport, Knox County, Maine - Hanson-Cramer House, End of Sea Street (moved from Pascal's Avenue), Rockport, Knox County, ME

  6. MTR, TRA603. FIRST FLOOR PLAN. REACTOR AT CENTER. TWENTYMETER CHOPPER ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    MTR, TRA-603. FIRST FLOOR PLAN. REACTOR AT CENTER. TWENTY-METER CHOPPER HOUSE. COFFIN TURNING ROLLS. REMOVABLE PANEL OVER CANAL ON EAST SIDE. NEW PLUG STORAGE ACCESS. DOOR SCHEDULE INDICATES STEEL (FOR VAULT), WIRE MESH, AND HOLLOW METAL TYPES. STORAGE AND ISSUE ROOM. SAFETY SHOWERS. DOORWAY TO WING, TRA-604. BLAW-KNOX 3150-803-2, 7/1950. INL INDEX NO. 531-0603-00-098-100561, REV. 10. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  7. A&M. TAN607 first floor plan for cold assembly area. Shows ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    A&M. TAN-607 first floor plan for cold assembly area. Shows special source vaults, X-ray room, instrument shops, and positions of large machines in component test laboratory. This drawing was re-drawn to show conditions in 1994. Ralph M. Parsons 902-3-ANP-607-A 100. Date of original: December 1952. Approved by INEEL Classification Office for public release. INEEL index code no. 034-060-00-693-106752 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  8. Field Evaluation of the Performance of the RTU Challenge Unit: Daikin Rebel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Katipamula, Srinivas; Wang, W.; Ngo, Hung

    2017-05-31

    Packaged rooftop air-conditioning units (RTUs) are used in 44% (2.5 million) of all commercial buildings, serving over 57% (46 billion square feet) of the commercial building floor space in the United States (EIA 2012). The primary energy consumption associated with RTUs is over 2.2 quads annually. Therefore, even a small improvement in efficiency or part-load operation of these units can lead to significant reductions in energy use and carbon emissions. Starting in 2011, the U.S. Department of Energy’s (DOE’s) Building Technologies Office funded a series of projects related to RTUs. Some projects were intended to improve the operating efficiency ofmore » the existing RTUs, while others were focused on improving the operating efficiency of new units. This report documents the field-testing and comparison of the seasonal efficiency of a state-of-art RTU Challenge unit and a standard unit. Section II provides the background for the work. Section III describes the measurement and verification plan for the field tests. Section IV describes the measurement and verification evaluation plan. The results are described in Section V. The lessons learned and recommendations for future work are presented in Section VI. A list of references is provided in Section VII.« less

  9. Digging up the Dirt.

    ERIC Educational Resources Information Center

    Knuffman, Susan M.

    1997-01-01

    Explores ways of maintaining school floors and carpeting that ensure students and staff are comfortable, safe, and healthy. Carpet maintenance for high- to low-traffic areas and cleaning procedures are examined, as are ways maintenance staff can work together to help ensure a successful flooring-maintenance plan. (GR)

  10. Dairy cow preferences for soft or hard flooring when standing or walking.

    PubMed

    Telezhenko, E; Lidfors, L; Bergsten, C

    2007-08-01

    Concrete is the most commonly used alley flooring in confined dairy herds because of its qualities of construction and ease of cleaning. Nevertheless, the hardness, abrasiveness, and slipperiness of concrete floors have adverse effects on animal well-being and health, and yielding rubber flooring is becoming popular as a way of improving the flooring conditions on walkways. The aim of this study was to investigate preferences of dairy cows for rubber compared with concrete flooring under the conditions of a commercial dairy farm. The study was conducted in an organic dairy herd with free-stall housing. Floor preference was tested on groups of standing cows in a 120-m2 holding pen before milking, and 1 yr later on a 12- x 3-m walkway. The holding pen and the walkway were divided lengthwise into 2 identical sections. Two types of solid rubber mats (soft and extra soft) were tested against solid concrete in the holding pen. Slatted and solid rubber mats were tested against slatted concrete in the walkway. Each floor type was tested over 4 d on the left side and 4 d on the right side of the holding pen and the walkway, respectively. Concrete flooring on both sides of the sections was tested as a control before the testing of different section materials. All observations of the distribution of cows in the sections were made from video recordings captured in association with the afternoon milking. The number of cows on each section was recorded approximately every 7 min in the holding pen, and continuously on the walkway. A significantly higher proportion of cows stood on the side with the soft and extra soft rubber mats (65.1 +/- 2.7 and 69.3 +/- 2.6%, respectively, mean +/- SEM) compared with the control distribution when only the solid concrete was available (50.9 +/- 3.9%). A significantly higher proportion of nonlame cows walked exclusively on the side with the slatted (64.5 +/- 5.4%, d 4) or solid rubber mats (68.2 +/- 5.1%, d 4) compared with controls (28.9 +/- 4.3%). Lame cows within a group of walking cows did not show a higher preference for soft flooring as distinct as nonlame cows (52.7 +/- 6.9 and 59.4 +/- 6.2% for the solid and slatted rubber mats, respectively, at d 4 vs. 40.3 +/- 6.2% for control), presumably because of competition with other, higher ranked cows. It was concluded that the majority of cows preferred to walk and stand on soft rubber rather than on concrete flooring.

  11. High-resolution geologic mapping of the inner continental shelf: Boston Harbor and approaches, Massachusetts

    USGS Publications Warehouse

    Ackerman, Seth D.; Butman, Bradford; Barnhardt, Walter A.; Danforth, William W.; Crocker, James M.

    2006-01-01

    This report presents the surficial geologic framework data and information for the sea floor of Boston Harbor and Approaches, Massachusetts (fig. 1.1). This mapping was conducted as part of a cooperative program between the U.S. Geological Survey (USGS), the Massachusetts Office of Coastal Zone Management (CZM), and the National Oceanic and Atmospheric Administration (NOAA). The primary objective of this project was to provide sea floor geologic information and maps of Boston Harbor to aid resource management, scientific research, industry and the public. A secondary objective was to test the feasibility of using NOAA hydrographic survey data, normally collected to update navigation charts, to create maps of the sea floor suitable for geologic and habitat interpretations. Defining sea-floor geology is the first steps toward managing ocean resources and assessing environmental changes due to natural or human activity. The geophysical data for these maps were collected as part of hydrographic surveys carried out by NOAA in 2000 and 2001 (fig. 1.2). Bottom photographs, video, and samples of the sediments were collected in September 2004 to help in the interpretation of the geophysical data. Included in this report are high-resolution maps of the sea floor, at a scale of 1:25,000; the data used to create these maps in Geographic Information Systems (GIS) format; a GIS project; and a gallery of photographs of the sea floor. Companion maps of sea floor to the north Boston Harbor and Approaches are presented by Barnhardt and others (2006) and to the east by Butman and others (2003a,b,c). See Butman and others (2004) for a map of Massachusetts Bay at a scale of 1:125,000. The sections of this report are listed in the navigation bar along the left-hand margin of this page. Section 1 (this section) introduces the report. Section 2 presents the large-format map sheets. Section 3 describes data collection, processing, and analysis. Section 4 summarizes the geologic history of the region and discusses geomorphic and anthropogenic features within the study area. Section 4 also provides references that contain additional information about the region. Appendix 1 provides GIS layers of all the data collected in this study, Appendix 2 contains the grain size textural analyses of sediment samples, and Appendix 3 contains bottom photographs of the sea floor in JPG format.

  12. 33. Photographic copy of architects plan dated October 1919 (original ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    33. Photographic copy of architects plan dated October 1919 (original in Possession of Montana State University, Bozeman Montana.) SECOND FLOOR PLAN - Hardin City Water Works, 101 East Fourth Street, Hardin, Big Horn County, MT

  13. 32. Photographic copy of architects plan dated October 1919 (original ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    32. Photographic copy of architects plan dated October 1919 (original in possession of Montana State University, Bozeman, Montana.) FIRST FLOOR PLAN - Hardin City Water Works, 101 East Fourth Street, Hardin, Big Horn County, MT

  14. Modification of one man life raft

    NASA Technical Reports Server (NTRS)

    Soter, E. J. (Inventor)

    1974-01-01

    A one man inflatable life raft is described. The raft has an inflatable tube perimetrically bounding the occupant receiving space with a flexible floor member. A zippered opening in the floor allows entry and facilitates the use of a constant diameter tube. An airtight fabric bulkhead divides the peripheral tube longitudinally into inflatable tube sections, where if either tube section were punctured, the bulkhead would move into the punctured section to substitute for the punctured wall portion and maintain the inflatable volume of the tube. The floor member is attached to the central portion of the tube wall so that either side of the raft can be the up side.

  15. Toward Autonomous Multi-floor Exploration: Ascending Stairway Localization and Modeling

    DTIC Science & Technology

    2013-03-01

    robots have traditionally been restricted to single floors of a building or outdoor areas free of abrupt elevation changes such as curbs and stairs ...solution to this problem and is motivated by the rich potential of an autonomous ground robot that can climb stairs while exploring a multi-floor...parameters of the stairways, the robot could plan a path that traverses the stairs in order to explore the frontier at other elevations that were previously

  16. 11. Interior view of first floor of 1922 north section, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. Interior view of first floor of 1922 north section, showing east wall and windows at far north end of building. Camera pointed E. Rear of building is partially visible on far left. - Puget Sound Naval Shipyard, Pattern Shop, Farragut Avenue, Bremerton, Kitsap County, WA

  17. View southeast of weldment assembly floor in structures shop, building ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View southeast of weldment assembly floor in structures shop, building 57; the floor is fabricated of cast iron and features a grillwork of 1 1/2 square holes which are used as sockets for gripping positioning or lock down pins; a lock down pin is shown left and below the center of the photograph; the vertical section of the pin is placed into a hole in the cast steel floor while the angles section of the pin rests on the piece under construction; the pin is hammered into the hole and spring tension in the pin holds the work piece in position. - Naval Base Philadelphia-Philadelphia Naval Shipyard, Structure Shop, League Island, Philadelphia, Philadelphia County, PA

  18. 24 CFR 3280.109 - Room requirements.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Planning Considerations § 3280.109 Room requirements. (a) Every manufactured home shall have at least one living area with not less than 150 sq. ft. of gross floor area. (b) Rooms designed for sleeping purposes shall have a minimum gross square foot floor...

  19. Materials for School Construction.

    ERIC Educational Resources Information Center

    Texas Education Agency, Austin.

    As an assist to the superintendent and members of his staff, this booklet has been prepared for obtaining information in the field of building, planning and construction. Topics discussed are--(1) structure, (2) roofs, (3) floor construction, (4) floor finishes, (5) ceilings, (6) exterior wall construction, (7) interior walls and partitions, (8)…

  20. 36 CFR 28.23 - Certificates of suspension of authority for acquisition by condemnation.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... developed area on the ground level; (2) On the survey, the line of mean high water, the toe of the dune, and the crest of the dune shall be identified if they traverse the lot; (3) A floor plan of each floor of...

  1. 7 CFR 3201.39 - Floor strippers.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 15 2013-01-01 2013-01-01 false Floor strippers. 3201.39 Section 3201.39 Agriculture... Items § 3201.39 Floor strippers. (a) Definition. Products that are formulated to loosen waxes, resins... strippers. By that date, Federal agencies that have the responsibility for drafting or reviewing...

  2. 7 CFR 3201.39 - Floor strippers.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 15 2014-01-01 2014-01-01 false Floor strippers. 3201.39 Section 3201.39 Agriculture... Items § 3201.39 Floor strippers. (a) Definition. Products that are formulated to loosen waxes, resins... strippers. By that date, Federal agencies that have the responsibility for drafting or reviewing...

  3. 7 CFR 3201.39 - Floor strippers.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 15 2012-01-01 2012-01-01 false Floor strippers. 3201.39 Section 3201.39 Agriculture... Items § 3201.39 Floor strippers. (a) Definition. Products that are formulated to loosen waxes, resins... strippers. By that date, Federal agencies that have the responsibility for drafting or reviewing...

  4. Use of high-resolution geophysical and geotechnical techniques for artificial reef site selection, west Cameron planning area, offshore Louisiana

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pope, D.L.; Wagner, J.B.

    1988-09-01

    Before siting oil and gas platforms on the sea floor as artificial reefs offshore Louisiana, potentially hazardous and unstable geologic conditions must be identified and evaluated to assess their possible impacts on platform stability. Geologic and man-made features can be identified and assessed from high-resolution geophysical techniques (3.5-7.0 kHz echograms, single-channel seismic, and side-scan sonar). Such features include faults, diapirs, scarps, channels, gas seeps, irregular sea floor topography, mass wasting deposits (slumps, slides, and debris flows), pipelines, and other subsea marine equipment. Geotechnical techniques are utilized to determine lithologic and physical properties of the sediments for correlation with the geophysicalmore » data. These techniques are used to develop a series of geologic maps, cross sections, and pipeline and platform-location maps. Construction of echo-character maps from 3.5-kHz data provides an analysis of near-bottom sedimentation processes (turbidity currents and debris flows).« less

  5. BUILDING A196 BARRACKS, FIRST FLOOR PLAN. Naval Guided Missile and ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    BUILDING A-196 BARRACKS, FIRST FLOOR PLAN. Naval Guided Missile and Tactical Data System School, Naval Schools Command, Mare Island, California. Milton T. Pflueger, Architect, 580 Market Street, San Francisco, CA. Sheet 126 of 145, specification 36050-61, approved for the Bureau of Yards and Docks, October 26, 1961. Yards and Docks drawing no. 892274; DPWO drawing no. B-75274; file no. 930-CR-1. 72 cm x 98 xm. Sepia tone print - Mare Island Naval Shipyard, Guard House & Barracks, Railroad Avenue near Eighteenth Street, Vallejo, Solano County, CA

  6. BUILDING A196 BARRACKS, SECOND FLOOR PLAN. Naval Guided Missile and ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    BUILDING A-196 BARRACKS, SECOND FLOOR PLAN. Naval Guided Missile and Tactical Data System School, Naval Schools Command, Mare Island, CA. Milton T. Pflueger, Architect, 580 Market Street, San Francisco, CA. Sheet 127 to 145, specification 36050/61, approved for the Bureau of Yards and Docks, October 26, 1961. Yards and Docks drawing no. 892275; DPWO drawing no. B-75275; file no. 930-CR-2. 72 cm x 98 cm. Sepia tone print - Mare Island Naval Shipyard, Guard House & Barracks, Railroad Avenue near Eighteenth Street, Vallejo, Solano County, CA

  7. Secondary Maxillary and Orbital Floor Reconstruction With a Free Scapular Flap Using Cutting and Fixation Guides Created by Computer-Aided Design/Computer-Aided Manufacturing.

    PubMed

    Morita, Daiki; Numajiri, Toshiaki; Tsujiko, Shoko; Nakamura, Hiroko; Yamochi, Ryo; Sowa, Yoshihiro; Yasuda, Makoto; Hirano, Shigeru

    2017-11-01

    Computer-aided design/computer-aided manufacturing (CAD/CAM) guides are now widely used in maxillofacial reconstruction. However, there are few reports of CAD/CAM guides being used for scapular flaps. The authors performed the secondary maxillary and orbital floor reconstruction using a free latissimus dorsi muscle, cutaneous tissue, and scapular flap designed using CAD/CAM techniques in a 72-year-old man who had undergone partial maxillectomy four years previously. The patient had diplopia, the vertical dystopia of eye position, and a large oral-nasal-cutaneous fistula. After the operation, the authors confirmed that the deviation between the postoperative and preoperative planning three-dimensional images was less than 2 mm. Because scapular guides require 3 cutting surfaces, the shape of the scapular guide is more complex than that of a conventional fibular guide. In orbital floor reconstruction, the use of a CAM technique such as that used to manufacture the authors' fixation guide is as necessary for accurate, safe, and easy reconstruction as is preoperative CAD planning. The production of a fixation guide as well as a cutting guide is particularly useful because it is difficult to determine the angle for reconstructing the orbital floor by freehand techniques. In this case, the orbital floor was reconstructed based on a mirror image of the healthy side to avoid overcompression of the orbital tissue. Although the patient's vertical dystopia of eye position was improved, diplopia was not improved because, for greater safety, the authors did not plan overcorrection of the orbital volume.

  8. 9 CFR 91.26 - Concrete flooring.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Concrete flooring. 91.26 Section 91.26... LIVESTOCK FOR EXPORTATION Inspection of Vessels and Accommodations § 91.26 Concrete flooring. (a) Pens aboard an ocean vessel shall have a 3 inch concrete pavement, proportioned and mixed to give 2000 psi...

  9. 24. Interior view of third floor attic of 1896 south ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    24. Interior view of third floor attic of 1896 south section of building. Note steel truss supports and wooden roof. Top floor round window in seen from outside in photo WA-116-A-2. - Puget Sound Naval Shipyard, Pattern Shop, Farragut Avenue, Bremerton, Kitsap County, WA

  10. 15. Photograph of line drawing in possession of Engineering Plans ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    15. Photograph of line drawing in possession of Engineering Plans and Services Division, Rock Island Arsenal. SECOND FLOOR PLAN, 1920. - Rock Island Arsenal, Building No. 90, East Avenue between North Avenue & King Drive, Rock Island, Rock Island County, IL

  11. 14. Photograph of line drawing in possession of Engineering Plans ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    14. Photograph of line drawing in possession of Engineering Plans and Services Division, Rock Island Arsenal. FIRST FLOOR PLAN, 1920. - Rock Island Arsenal, Building No. 90, East Avenue between North Avenue & King Drive, Rock Island, Rock Island County, IL

  12. Planning and Equipping a New Machine Shop

    ERIC Educational Resources Information Center

    Bloom, Nick

    1978-01-01

    The author describes the planning and equipping of a new machine shop facility at the East Los Angeles Occupational Center. Lists of machine shop and classroom equipment, a floor plan of the facility, and some new shop curriculum approaches are included. (MF)

  13. 34. Photographic copy of architects plan dated October 1919, (original ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    34. Photographic copy of architects plan dated October 1919, (original in possession of Montana State University, Bozeman, Montana.) REVISED PLAN AT 2nd FLOOR MAIN STAIRS - Hardin City Water Works, 101 East Fourth Street, Hardin, Big Horn County, MT

  14. Architectural Drafting, Drafting 2: 9255.04.

    ERIC Educational Resources Information Center

    Dade County Public Schools, Miami, FL.

    The course covers the basic fundamentals of architectural drafting and is not intended to delve into the more advanced phases of architecture. The student is presented with standards and procedures, and will become proficient in layout of floor plans, electrical plans, roof construction, foundation plans, typical wall construction, plot plans, and…

  15. 117. ARAI Shop and maintenance (ARA627) building roof and floor ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    117. ARA-I Shop and maintenance (ARA-627) building roof and floor plan. Includes room finish and equipment schedule. Norman Engineering Company 961-area/SF-627-A-1. Date: January 1959. Ineel index code no. 068-0627-00-613-102759. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID

  16. 77 FR 32151 - Self-Regulatory Organizations; NASDAQ OMX PHLX LLC; Notice of Filing and Immediate Effectiveness...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-31

    ... proposed rule change is to correct Rule 616 to correspond to amended Equity Floor Procedure Advice (``EFPA'') A-7 and Options Floor Procedure Advice (``OFPA'') F-34 (together, the ``Advices'').\\5\\ \\5\\ The... plans for the abbreviated reporting of minor disciplinary infractions. Any disciplinary action taken by...

  17. 7. Photocopy of War Department drawing (original located at Fort ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. Photocopy of War Department drawing (original located at Fort McCoy, Wisconsin). FLOOR PLAN & ROOF FRAMING PLAN, PLAN NUMBER 1496 - Fort McCoy, Building No. T-1033, North side of South Tenth Avenue, Block 10, Sparta, Monroe County, WI

  18. 49 CFR 214.519 - Floors, decks, stairs, and ladders of on-track roadway maintenance machines.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... roadway maintenance machines. 214.519 Section 214.519 Transportation Other Regulations Relating to... SAFETY On-Track Roadway Maintenance Machines and Hi-Rail Vehicles § 214.519 Floors, decks, stairs, and ladders of on-track roadway maintenance machines. Floors, decks, stairs, and ladders of on-track roadway...

  19. 49 CFR 214.519 - Floors, decks, stairs, and ladders of on-track roadway maintenance machines.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... roadway maintenance machines. 214.519 Section 214.519 Transportation Other Regulations Relating to... SAFETY On-Track Roadway Maintenance Machines and Hi-Rail Vehicles § 214.519 Floors, decks, stairs, and ladders of on-track roadway maintenance machines. Floors, decks, stairs, and ladders of on-track roadway...

  20. [Pelvic floor and pregnancy].

    PubMed

    Fritel, X

    2010-05-01

    Congenital factor, obesity, aging, pregnancy and childbirth are the main risk factors for female pelvic floor disorders (urinary incontinence, anal incontinence, pelvic organ prolapse, dyspareunia). Vaginal delivery may cause injury to the pudendal nerve, the anal sphincter, or the anal sphincter. However the link between these injuries and pelvic floor symptoms is not always determined and we still ignore what might be the ways of prevention. Of the many obstetrical methods proposed to prevent postpartum symptoms, episiotomy, delivery in vertical position, delayed pushing, perineal massage, warm pack, pelvic floor rehabilitation, results are disappointing or limited. Caesarean section is followed by less postnatal urinary incontinence than vaginal childbirth. However this difference tends to disappear with time and following childbirth. Limit the number of instrumental extractions and prefer the vacuum to forceps could reduce pelvic floor disorders after childbirth. Ultrasound examination of the anal sphincter after a second-degree perineal tear is useful to detect and repair infra-clinic anal sphincter lesions. Scientific data is insufficient to justify an elective cesarean section in order to avoid pelvic floor symptoms in a woman without previous disorders. Copyright 2010 Elsevier Masson SAS. All rights reserved.

  1. Dose-Effect Relationships for Individual Pelvic Floor Muscles and Anorectal Complaints After Prostate Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smeenk, Robert Jan, E-mail: r.smeenk@rther.umcn.nl; Hoffmann, Aswin L.; Hopman, Wim P.M.

    2012-06-01

    Purpose: To delineate the individual pelvic floor muscles considered to be involved in anorectal toxicity and to investigate dose-effect relationships for fecal incontinence-related complaints after prostate radiotherapy (RT). Methods and Materials: In 48 patients treated for localized prostate cancer, the internal anal sphincter (IAS) muscle, the external anal sphincter (EAS) muscle, the puborectalis muscle (PRM), and the levator ani muscles (LAM) in addition to the anal wall (Awall) and rectal wall (Rwall) were retrospectively delineated on planning computed tomography scans. Dose parameters were obtained and compared between patients with and without fecal urgency, incontinence, and frequency. Dose-effect curves were constructed.more » Finally, the effect of an endorectal balloon, which was applied in 28 patients, was investigated. Results: The total volume of the pelvic floor muscles together was about three times that of the Awall. The PRM was exposed to the highest RT dose, whereas the EAS received the lowest dose. Several anal and rectal dose parameters, as well as doses to all separate pelvic floor muscles, were associated with urgency, while incontinence was associated mainly with doses to the EAS and PRM. Based on the dose-effect curves, the following constraints regarding mean doses could be deduced to reduce the risk of urgency: {<=}30 Gy to the IAS; {<=}10 Gy to the EAS; {<=}50 Gy to the PRM; and {<=}40 Gy to the LAM. No dose-effect relationships for frequency were observed. Patients treated with an endorectal balloon reported significantly less urgency and incontinence, while their treatment plans showed significantly lower doses to the Awall, Rwall, and all pelvic floor muscles. Conclusions: Incontinence-related complaints show specific dose-effect relationships to individual pelvic floor muscles. Dose constraints for each muscle can be identified for RT planning. When only the Awall is delineated, substantial components of the continence apparatus are excluded.« less

  2. Dose-effect relationships for individual pelvic floor muscles and anorectal complaints after prostate radiotherapy.

    PubMed

    Smeenk, Robert Jan; Hoffmann, Aswin L; Hopman, Wim P M; van Lin, Emile N J Th; Kaanders, Johannes H A M

    2012-06-01

    To delineate the individual pelvic floor muscles considered to be involved in anorectal toxicity and to investigate dose-effect relationships for fecal incontinence-related complaints after prostate radiotherapy (RT). In 48 patients treated for localized prostate cancer, the internal anal sphincter (IAS) muscle, the external anal sphincter (EAS) muscle, the puborectalis muscle (PRM), and the levator ani muscles (LAM) in addition to the anal wall (Awall) and rectal wall (Rwall) were retrospectively delineated on planning computed tomography scans. Dose parameters were obtained and compared between patients with and without fecal urgency, incontinence, and frequency. Dose-effect curves were constructed. Finally, the effect of an endorectal balloon, which was applied in 28 patients, was investigated. The total volume of the pelvic floor muscles together was about three times that of the Awall. The PRM was exposed to the highest RT dose, whereas the EAS received the lowest dose. Several anal and rectal dose parameters, as well as doses to all separate pelvic floor muscles, were associated with urgency, while incontinence was associated mainly with doses to the EAS and PRM. Based on the dose-effect curves, the following constraints regarding mean doses could be deduced to reduce the risk of urgency: ≤ 30 Gy to the IAS; ≤ 10 Gy to the EAS; ≤ 50 Gy to the PRM; and ≤ 40 Gy to the LAM. No dose-effect relationships for frequency were observed. Patients treated with an endorectal balloon reported significantly less urgency and incontinence, while their treatment plans showed significantly lower doses to the Awall, Rwall, and all pelvic floor muscles. Incontinence-related complaints show specific dose-effect relationships to individual pelvic floor muscles. Dose constraints for each muscle can be identified for RT planning. When only the Awall is delineated, substantial components of the continence apparatus are excluded. Copyright © 2012 Elsevier Inc. All rights reserved.

  3. Finite Element Analysis of an Energy Absorbing Sub-floor Structure

    NASA Technical Reports Server (NTRS)

    Moore, Scott C.

    1995-01-01

    As part of the Advanced General Aviation Transportation Experiments program, the National Aeronautics and Space Administration's Langley Research Center is conducting tests to design energy absorbing structures to improve occupant survivability in aircraft crashes. An effort is currently underway to design an Energy Absorbing (EA) sub-floor structure which will reduce occupant loads in an aircraft crash. However, a recent drop test of a fuselage specimen with a proposed EA sub-floor structure demonstrated that the effects of sectioning the fuselage on both the fuselage section's stiffness and the performance of the EA structure were not fully understood. Therefore, attempts are underway to model the proposed sub-floor structure on computers using the DYCAST finite element code to provide a better understanding of the structure's behavior in testing, and in an actual crash.

  4. 7. This photographic copy of an engineering drawing displays the ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. This photographic copy of an engineering drawing displays the building's floor plan in its 1995 arrangement, with rooms designated. California Institute of Technology, Jet Propulsion Laboratory, Facilities Engineering and Construction Office, "Addition to Weigh & Control Bldg. E-35, Demolition, Floor and Roof Plans," drawing no. E35/3-0, October 5, 1983. California Institute of Technology, Jet Propulsion Laboratory, Plant Engineering: engineering drawings of structures at JPL Edwards Facility. Drawings on file at JPL Plant Engineering, Pasadena, California. - Jet Propulsion Laboratory Edwards Facility, Weigh & Control Building, Edwards Air Force Base, Boron, Kern County, CA

  5. 7 CFR Exhibit B to Subpart A of... - Requirements for Modular/Panelized Housing Units

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ..., log wall houses, trussed roof rafters or floor trusses; open panel walls, and other types that can be... windows or crawl space vents with all sizes indicated. 2. Floor Plans of all levels. Show square footage... levels is required to indicate intended occupancy functions of the design. A window and door schedule...

  6. 7 CFR Exhibit B to Subpart A of... - Requirements for Modular/Panelized Housing Units

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ..., log wall houses, trussed roof rafters or floor trusses; open panel walls, and other types that can be... windows or crawl space vents with all sizes indicated. 2. Floor Plans of all levels. Show square footage... levels is required to indicate intended occupancy functions of the design. A window and door schedule...

  7. 15. Photocopy of Sheet 1 of Building Plan R41A, (USDA, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    15. Photocopy of Sheet 1 of Building Plan R4-1A, (USDA, Forest Service, Intermountain Region, Ogden. File 7300, 'Buildings'.) FRONT ELEVATION AND FLOOR PLAN - Buffalo Guard Station, Residence, U.S. Highway 20/191 at Buffalo River, Island Park, Fremont County, ID

  8. 10. Photocopy of Sheet 1 of Building Plan R453 (USDA, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Photocopy of Sheet 1 of Building Plan R4-53 (USDA, Forest Service, Intermountain Region, Ogden. File 7300, 'Buildings'.) FRONT AND SIDE ELEVATIONS AND FLOOR PLAN - Buffalo Guard Station, Residence, U.S. Highway 20/191 at Buffalo River, Island Park, Fremont County, ID

  9. A BASIS FOR MODIFYING THE TANK 12 COMPOSITE SAMPLING DESIGN

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shine, G.

    The SRR sampling campaign to obtain residual solids material from the Savannah River Site (SRS) Tank Farm Tank 12 primary vessel resulted in obtaining appreciable material in all 6 planned source samples from the mound strata but only in 5 of the 6 planned source samples from the floor stratum. Consequently, the design of the compositing scheme presented in the Tank 12 Sampling and Analysis Plan, Pavletich (2014a), must be revised. Analytical Development of SRNL statistically evaluated the sampling uncertainty associated with using various compositing arrays and splitting one or more samples for compositing. The variance of the simple meanmore » of composite sample concentrations is a reasonable standard to investigate the impact of the following sampling options. Composite Sample Design Option (a). Assign only 1 source sample from the floor stratum and 1 source sample from each of the mound strata to each of the composite samples. Each source sample contributes material to only 1 composite sample. Two source samples from the floor stratum would not be used. Composite Sample Design Option (b). Assign 2 source samples from the floor stratum and 1 source sample from each of the mound strata to each composite sample. This infers that one source sample from the floor must be used twice, with 2 composite samples sharing material from this particular source sample. All five source samples from the floor would be used. Composite Sample Design Option (c). Assign 3 source samples from the floor stratum and 1 source sample from each of the mound strata to each composite sample. This infers that several of the source samples from the floor stratum must be assigned to more than one composite sample. All 5 source samples from the floor would be used. Using fewer than 12 source samples will increase the sampling variability over that of the Basic Composite Sample Design, Pavletich (2013). Considering the impact to the variance of the simple mean of the composite sample concentrations, the recommendation is to construct each sample composite using four or five source samples. Although the variance using 5 source samples per composite sample (Composite Sample Design Option (c)) was slightly less than the variance using 4 source samples per composite sample (Composite Sample Design Option (b)), there is no practical difference between those variances. This does not consider that the measurement error variance, which is the same for all composite sample design options considered in this report, will further dilute any differences. Composite Sample Design Option (a) had the largest variance for the mean concentration in the three composite samples and should be avoided. These results are consistent with Pavletich (2014b) which utilizes a low elevation and a high elevation mound source sample and two floor source samples for each composite sample. Utilizing the four source samples per composite design, Pavletich (2014b) utilizes aliquots of Floor Sample 4 for two composite samples.« less

  10. Pelvic floor muscle strength of women consulting at the gynecology outpatient clinics and its correlation with sexual dysfunction: A cross-sectional study.

    PubMed

    Ozdemir, Filiz Ciledag; Pehlivan, Erkan; Melekoglu, Rauf

    2017-01-01

    To investigate the pelvic floor muscle strength of the women andevaluateits possible correlation with sexual dysfunction. In this cross-sectional type study, stratified clusters were used for the sampling method. Index of Female Sexual Function (IFSF) worksheetwere used for questions on sexual function. The pelvic floor muscle strength of subjects was assessed byperineometer. The chi-squared test, logistic regression and Pearson's correlation analysis were used for the statistical analysis. Four hundred thirty primiparous women, mean age 38.5 participated in this study. The average pelvic floor muscle strength value was found 31.4±9.6 cm H 2 O and the average Index of Female Sexual Function (IFSF) score was found 26.5±6.9. Parity (odds ratio OR=5.546) and age 40 or higher (OR=3.484) were found correlated with pelvic floor muscle weakness (p<0.05). The factors directly correlated with sexual dysfunction were found being overweight (OR=2.105) and age 40 or higher (OR=2.451) (p<0.05). Pearson's correlation analysis showed that there was a statistically significantlinear correlation between the muscular strength of the pelvic floor and sexual function (p=0.001). The results suggested subjects with decreased pelvic floor muscle strength value had higher frequency of sexual dysfunction.

  11. LOFT. Containment and service building (TAN650). Section through north/south axis. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    LOFT. Containment and service building (TAN-650). Section through north/south axis. Shows basement and four additional levels of pre-amp tower, shielded roadway, chambers below reactor floor, railroad door, sumps, shielding. Section C shows basement sumps and chambers below reactor floor. Kaiser engineers 6413-11-STEP/LOFT-650-A-5. Date: October 1964. INEEL index code no. 036-650-00-486-122217 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  12. Role of conventional radiology and MRi defecography of pelvic floor hernias

    PubMed Central

    2013-01-01

    Background Purpose of the study is to define the role of conventional radiology and MRI in the evaluation of pelvic floor hernias in female pelvic floor disorders. Methods A MEDLINE and PubMed search was performed for journals before March 2013 with MeSH major terms 'MR Defecography' and 'pelvic floor hernias'. Results The prevalence of pelvic floor hernias at conventional radiology was higher if compared with that at MRI. Concerning the hernia content, there were significantly more enteroceles and sigmoidoceles on conventional radiology than on MRI, whereas, in relation to the hernia development modalities, the prevalence of elytroceles, edroceles, and Douglas' hernias at conventional radiology was significantly higher than that at MRI. Conclusions MRI shows lower sensitivity than conventional radiology in the detection of pelvic floor hernias development. The less-invasive MRI may have a role in a better evaluation of the entire pelvic anatomy and pelvic organ interaction especially in patients with multicompartmental defects, planned for surgery. PMID:24267789

  13. 46. Photograph of an original construction drawing, dated August 1927, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    46. Photograph of an original construction drawing, dated August 1927, in the possession of Facilities planning Office, Iowa State University, Ames, Iowa. SECOND FLOOR PLAN, ROOF PLANS, AND ROOF DETAILS; SHEET NO. 4 OF 10 - Dairy Industry Building, Iowa State University campus, Ames, Story County, IA

  14. 9. Photocopy of Sheet 1 of Building Plan R451, (USDA, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. Photocopy of Sheet 1 of Building Plan R4-51, (USDA, Forest Service, Intermountain Region, Ogden. File 7300, 'Buildings'.) Front, Rear, and Side Elevations and Floor Plan. - Buffalo Guard Station, Office, U.S. Highway 20/191 at Buffalo River, Island Park, Fremont County, ID

  15. 4. Photocopy of Sheet 1 of Building Plan R421, (USDA, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. Photocopy of Sheet 1 of Building Plan R4-21, (USDA, Forest Service, Intermountain Region, Ogden. File 7300, 'Buildings') FRONT AND SIDE ELEVATIONS, FLOOR AND FOUNDATION PLANS. - Buffalo Guard Station, Garage, U.S. Highway 20/191 at Buffalo River, Island Park, Fremont County, ID

  16. 16. Interior view on first floor in 1904 middle section, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    16. Interior view on first floor in 1904 middle section, east side, showing various machinery, including Post Lathe (Bull Lathe) with Large wheel and smaller lathe on left. Camera pointed S on east side building. See photos WA-116-A-17 through WA-116-A-20. - Puget Sound Naval Shipyard, Pattern Shop, Farragut Avenue, Bremerton, Kitsap County, WA

  17. Graduate House, University of Toronto, Ontario.

    ERIC Educational Resources Information Center

    Stephens, Suzanne

    2002-01-01

    Illustrates how the University of Toronto combined the modernist architectural typologies of perimeter block and the skip- stop plan to create a dormitory that served as a gateway to its campus. Photos and a floor plan are included. (GR)

  18. Searching for Planning and Design Solutions.

    ERIC Educational Resources Information Center

    Roark, Steven

    2001-01-01

    Presents the fourth article in a series on the Longview Community College (Kansas City, Missouri) Liberal Arts building project. How architects are revising floor plans, evaluating building systems, deciding on furniture, and dealing with building codes are discussed. (GR)

  19. Supervised pelvic floor muscle training versus attention-control massage treatment in patients with faecal incontinence: Statistical analysis plan for a randomised controlled trial.

    PubMed

    Ussing, Anja; Dahn, Inge; Due, Ulla; Sørensen, Michael; Petersen, Janne; Bandholm, Thomas

    2017-12-01

    Faecal incontinence affects approximately 8-9% of the adult population. The condition is surrounded by taboo; it can have a devastating impact on quality of life and lead to major limitations in daily life. Pelvic floor muscle training in combination with information and fibre supplements is recommended as first-line treatment for faecal incontinence. Despite this, the effect of pelvic floor muscle training for faecal incontinence is unclear. No previous trials have investigated the efficacy of supervised pelvic floor muscle training in combination with conservative treatment and compared this to an attention-control massage treatment including conservative treatment. The aim of this trial is to investigate if 16 weeks of supervised pelvic floor muscle training in combination with conservative treatment is superior to attention-control massage treatment and conservative treatment in patients with faecal incontinence. Randomised, controlled, superiority trial with two parallel arms. 100 participants with faecal incontinence will be randomised to either (1) individually supervised pelvic floor muscle training and conservative treatment or (2) attention-control massage treatment and conservative treatment. The primary outcome is participants' rating of symptom changes after 16 weeks of treatment using the Patient Global Impression of Improvement Scale. Secondary outcomes are the Vaizey Incontinence Score, the Fecal Incontinence Severity Index, the Fecal Incontinence Quality of Life Scale, a 14-day bowel diary, anorectal manometry and rectal capacity measurements. Follow-up assessment at 36 months will be conducted. This paper describes and discusses the rationale, the methods and in particular the statistical analysis plan of this trial.

  20. Turbine blade squealer tip rail with fence members

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Little, David A

    2012-11-20

    A turbine blade includes an airfoil, a blade tip section, a squealer tip rail, and a plurality of chordally spaced fence members. The blade tip section includes a blade tip floor located at an end of the airfoil distal from the root. The blade tip floor includes a pressure side and a suction side joined together at chordally spaced apart leading and trailing edges of the airfoil. The squealer tip rail extends radially outwardly from the blade tip floor adjacent to the suction side and extends from a first location adjacent to the airfoil trailing edge to a second locationmore » adjacent to the airfoil leading edge. The fence members are located between the airfoil leading and trailing edges and extend radially outwardly from the blade tip floor and axially from the squealer tip rail toward the pressure side.« less

  1. Evaluation of common cleaning and disinfection programmes in battery cage and on-floor layer houses in France.

    PubMed

    Huneau-Salaün, A; Michel, V; Balaine, L; Petetin, I; Eono, F; Ecobichon, F; Bouquin, S Le

    2010-04-01

    1. The aim in this study was to evaluate cleaning and disinfection programmes in battery cage and on-floor layer houses in France. 2. Cleaning and disinfection efficiency was assessed by a visual evaluation of cleaning and a bacteriological monitoring of surface contamination from counts of thermotolerant streptococci on contact agar plates. 3. In battery cage houses, dropping belts, manure conveyors, and house floors remained highly contaminated due to poor cleaning in half of the buildings examined. 4. In on-floor houses, a high standard of cleaning was achieved but errors in the planning of cleaning and disinfection operations sometimes led to a high residual contamination of nest boxes and egg sorting tables.

  2. 48. Photocopy of copy of original Officers' Duplex Quarters drawing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    48. Photocopy of copy of original Officers' Duplex Quarters drawing by Turner, 7 April 1932 (original in possession of Veterans Administration, Wichita, Kansas, copy at Ablah Library, Wichita State University). Attic and roof, basement, first floor, and second floor plans - Veterans Administration Center, Officers Duplex Quarters, 5302 East Kellogg (Legal Address); 5500 East Kellogg (Common Address), Wichita, Sedgwick County, KS

  3. 127. ARAII Administrative and technical support building (ARA606) ground floor ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    127. ARA-II Administrative and technical support building (ARA-606) ground floor plan. Indicates use of rooms for classrooms, offices, and lunch room. C.A. Sundberg and Associates 866-area-ALPR-606-A-2. Date: June 1958. Ineel index code no. 070-0606-00-822-102825. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID

  4. ICU fire evacuation preparedness in London: a cross-sectional study.

    PubMed

    Murphy, G R F; Foot, C

    2011-05-01

    Hospital fires present a sporadic but significant threat to patients and staff. This is especially so within an intensive care unit (ICU) setting, due to the complexity of moving acutely unwell patients reliant on invasive monitoring and organ support. Despite an average of 500 in-hospital fires reported to the UK department of health per annum, causing 65 injuries and 1-2 fatalities, the readiness of ICUs for urgent evacuation has not been assessed. A cross-sectional survey of all 50 adult and paediatric ICUs within the London Postgraduate Deanery was conducted; neonatal units were excluded. The senior nurse at each unit was asked to complete a 90-question structured questionnaire, covering unit patient characteristics, design, equipment, training, and their evacuation plan. Thirty-five of 50 (70%) responded within 2 months of the study. Significant weaknesses were reported in unit design, equipment, and planning. Unit design was compromised by inadequate fire doors (20%), ventilation cut-outs (17%), and escape routes (up to 60%). The ability to evacuate multiple patients simultaneously may be limited by a lack of portable monitoring equipment (49% of beds) and emergency drug supplies (20% of beds). Evacuation plans were often limited in their scope (96% expected to remain on their floor; 14% had plans to obtain medications after evacuation), and not rehearsed (60%). Staff training, while well provided for permanent staff, is less so for temporary staff (34%). Forward planning for an urgent evacuation can be improved.

  5. Elevated waterproof access floor system and method of making the same

    NASA Technical Reports Server (NTRS)

    Cohen, Marc M. (Inventor)

    1987-01-01

    An elevated waterproof access floor system having subfloor channels or compartments for power lines, gas lines or the like is adapted such that it can be opened and subsequently resealed without destroying the waterproofing and without destroying its aesthetic appearance. A multiplicity of tiles are supported on a support grid, and a flooring sheet is supported on the tiles. Attachment means are provided to prevent lateral but not vertical movement of the flooring sheet with respect to the tiles so that the flooring sheet can be lifted off the tiles, but when the flooring sheet is supported on the tiles, no lateral slipping will occur. The flooring sheet is made of a heat resealable material, so that it can be cut away in sections, and the tiles therebelow lifted off, to provide access to subfloor compartments.

  6. Role of chronic exercise on pelvic floor support and function

    PubMed Central

    Shaw, Janet M.; Nygaard, Ingrid E.

    2017-01-01

    Purpose of review To summarize recent literature about the potential role of chronic exercise on pelvic floor support and function. Recent findings Stress urinary incontinence is common during physical activity. Scant evidence suggests a dose-response association between higher volumes of exercise and urinary incontinence. Athletes do not appear to have greater pelvic floor muscle strength or worse pelvic floor support compared to non-athletes. Pelvic floor muscle electromyographic activity increases substantially as running speeds increase. Summary Based on the current literature, no strong conclusions can be drawn about whether chronic exercise exerts a positive or negative influence on pelvic floor support and function. Adopting longitudinal research methodology that prospectively monitors exercise exposure and subsequent changes in pelvic floor support and function would help to reduce selection bias associated with cross sectional studies on groups of athletes. PMID:28212118

  7. RECOMMENDATIONS FOR SAMPLING OF TANK 18 IN F TANK FARM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shine, G.

    2009-12-14

    Representative sampling is required for characterization of the residual floor material in Tank 18 prior to operational closure. Tank 18 is an 85-foot diameter, 34-foot high carbon steel tank with nominal operating volume of 1,300,000 gallons. It is a Type IV tank, and has been in service storing radioactive materials since 1959. Recent mechanical cleaning of the tank removed all mounds of material. Anticipating a low level of solids in the residual material, Huff and Thaxton [2009] developed a plan to sample the material during the final clean-up process while it would still be resident in sufficient quantities to supportmore » analytical determinations in four quadrants of the tank. Execution of the plan produced fewer solids than expected to support analytical determinations in all four quadrants. Huff and Thaxton [2009] then restructured the plan to characterize the residual floor material separately in the North and the South regions: two 'hemispheres.' This document provides sampling recommendations to complete the characterization of the residual material on the tank bottom following the guidance in Huff and Thaxton [2009] to split the tank floor into a North and a South hemisphere. The number of samples is determined from a modification of the formula previously published in Edwards [2001] and the sample characterization data for previous sampling of Tank 18 described by Oji [2009]. The uncertainty is quantified by an upper 95% confidence limit (UCL95%) on each analyte's mean concentration in Tank 18. The procedure computes the uncertainty in analyte concentration as a function of the number of samples, and the final number of samples is determined when the reduction in the uncertainty from an additional sample no longer has a practical impact on results. The characterization of the full suite of analytes in the North hemisphere is currently supported by a single Mantis rover sample obtained from a compact region near the center riser. A floor scrape sample was obtained from a compact region near the northeast riser and has been analyzed for a shortened list of key analytes. Since the unused portion of the floor scrape sample material is archived and available in sufficient quantity, additional analyses need to be performed to complete results for the full suite of constituents. The characterization of the full suite of analytes in the South hemisphere is currently supported by a single Mantis rover sample; there have been no floor scrape samples previously taken from the South hemisphere. The criterion to determine the number of additional samples was based on the practical reduction in the uncertainty when a new sample is added. This was achieved when five additional samples are obtained. In addition, two archived samples will be used if a contingency such as failing to demonstrate the comparability of the Mantis samples to the floor scrape samples occurs. To complete sampling of the Tank 18 residual floor material, three additional samples should be taken from the North hemisphere and four additional samples should be taken from the South hemisphere. One of the samples from each hemisphere will be archived in case of need. Two of the three additional samples from the North hemisphere and three of the four additional samples from the South hemisphere will be analyzed. Once the results are available, differences between the Mantis and three floor scrape samples (the sample previously obtained near NE riser plus the two additional samples that will be analyzed) results will be evaluated. If there are no statistically significant analyte concentration differences between the Mantis and floor scrape samples, those results will be combined and then UCL95%s will be calculated. If the analyte concentration differences between the Mantis and floor scrape samples are statistically significant, the UCL95%s will be calculated without the Mantis sample results. If further reduction in the upper confidence limits is needed and can be achieved by the addition of the archived samples, they will be analyzed and included in the statistical computations. Initially, the analyte concentrations in the residual material on the floor of Tank 18 will be determined separately in the North and the South hemispheres. However, if final sampling results show that differences between the North and South samples are consistent within sampling variation, then the final computations can be based on consolidating all sample results from the tank floor. Recommended locations may be subject to physical tank access and sampling constraints for the additional samples. The recommendations have been discussed in Section 4 and are based on partitioning the Tank 18 floor into an inner and an outer ring and six 60{sup o} sectors depicted in Figure 1. The location of the border between the inner and outer rings is based on dividing the residual material into two approximately equal volumes.« less

  8. 19. NORTH STAIRHALL (THERE ARE TWO FIRST FLOOR STAIRHALLS IN ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    19. NORTH STAIRHALL (THERE ARE TWO FIRST FLOOR STAIRHALLS IN THE HOUSE, ONE IN THE WEST SECTION AND THE OTHER IN THE NORTH SECTION). NOTE ARTIFICALLY GRAINED DOOR SURROUND. ON THE WALL IS LATE NINETEENTH OR EARLY TWENTIETH CENTURY KNOB AND TUBE WIRING WITH ORIGINAL WOOD FUSE BOX. MODERN JUNCTION BOX IS AT LEFT. - Colonel McNeal House, Union & Bills Streets, Bolivar, Hardeman County, TN

  9. a Schema for Extraction of Indoor Pedestrian Navigation Grid Network from Floor Plans

    NASA Astrophysics Data System (ADS)

    Niu, Lei; Song, Yiquan

    2016-06-01

    The requirement of the indoor navigation related tasks such emergency evacuation calls for efficient solutions for handling data sources. Therefore, the navigation grid extraction from existing floor plans draws attentions. To this, we have to thoroughly analyse the source data, such as Autocad dxf files. Then, we could establish a sounding navigation solution, which firstly complements the basic navigation rectangle boundaries, secondly subdivides these rectangles and finally generates accessible networks with these refined rectangles. Test files are introduced to validate the whole workflow and evaluate the solution performance. In conclusion, we have achieved the preliminary step of forming up accessible network from the navigation grids.

  10. ARCHITECTURE FOR ADULT EDUCATION. A GRAPHIC GUIDE FOR THOSE WHO ARE PLANNING PHYSICAL FACILITIES FOR ADULT EDUCATION.

    ERIC Educational Resources Information Center

    BECKER, JOHN W.

    THIS BOOK IS DESIGNED PARTICULARLY FOR THOSE PLANNING PHYSICAL FACILITIES FOR ADULT EDUCATION. FLOOR PLANS, PHOTOGRAPHS AND DISCUSSION ARE GIVEN FOR BUILDINGS USED FOR HOSPITALS, HEALTH CENTERS, INDUSTRY, ELEMENTARY SCHOOLS, HIGH SCHOOLS, COLLEGE BUILDINGS, FINE ARTS, LIBRARIES, RECREATION COMMUNITY CENTERS, AND ADULT EDUCATION. COPIES OF THIS…

  11. 24. PHOTOCOPY OF PLAN DRAWING. Quartermaster Research and Development Laboratory, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    24. PHOTOCOPY OF PLAN DRAWING. Quartermaster Research and Development Laboratory, Natick, Mass, Climatic Building, First Floor Plan, Architectural. Drawing No. 35-07-01, Sheet 2 of 72, 1952, updated to 1985. (Source: NRDEC). - Natick Research & Development Laboratories, Climatic Chambers Building, U.S. Army Natick Research, Development & Engineering Center (NRDEC), Natick, Middlesex County, MA

  12. Athletic Facilities: Planning, Designing, and Operating Today's Physical-Education Centers.

    ERIC Educational Resources Information Center

    Spoor, Dana L.

    1998-01-01

    Examines what should be featured in an athletic facility, how to plan for the many different sports and activities that will be housed, and how to get the community involved. Areas addressed include planning for locker rooms and storage, flooring and lighting, building code adherence, spectator seating, building security, and outdoor recreation…

  13. 25. PHOTOCOPY OF PLAN DRAWING. Quartermaster Research and Development Laboratory, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    25. PHOTOCOPY OF PLAN DRAWING. Quartermaster Research and Development Laboratory, Natick, Mass. Climatic Building, First Floor Plan, Refrigeration and Engineering. Drawing No. 35-07-01, Sheet 52 of 72, 1952. (Source: NRDEC). - Natick Research & Development Laboratories, Climatic Chambers Building, U.S. Army Natick Research, Development & Engineering Center (NRDEC), Natick, Middlesex County, MA

  14. Residential smoke alarms and fire escape plans.

    PubMed

    Harvey, P A; Sacks, J J; Ryan, G W; Bender, P F

    1998-01-01

    To estimate the proportion of U.S. homes with installed smoke alarms, smoke alarms on the same floor as occupants' bedrooms, and fire escape plans. The authors analyzed data on smoke alarm use and fire escape planning from a 1994 stratified random telephone survey of 5238 U.S. households. Respondents from 91% of surveyed households reported the presence of at least one installed smoke alarm, and 94% of respondents reported having an alarm on the same level of the home as their sleeping area. The prevalence of installed smoke alarms varied by highest education level in the household and income level. Sixty percent of all households had designed or discussed a fire escape plan at least once; only 17% of these households had actually practiced one. Although overall use of smoke alarms was high, certain population subgroups were less likely to have smoke alarms or to have them installed on the same floor as bedrooms. Fire escape planning, another important safety measure, was somewhat less common, and very few respondents reported having practiced a fire escape plan with the members of their household.

  15. Residential smoke alarms and fire escape plans.

    PubMed Central

    Harvey, P A; Sacks, J J; Ryan, G W; Bender, P F

    1998-01-01

    OBJECTIVE: To estimate the proportion of U.S. homes with installed smoke alarms, smoke alarms on the same floor as occupants' bedrooms, and fire escape plans. METHODS: The authors analyzed data on smoke alarm use and fire escape planning from a 1994 stratified random telephone survey of 5238 U.S. households. RESULTS: Respondents from 91% of surveyed households reported the presence of at least one installed smoke alarm, and 94% of respondents reported having an alarm on the same level of the home as their sleeping area. The prevalence of installed smoke alarms varied by highest education level in the household and income level. Sixty percent of all households had designed or discussed a fire escape plan at least once; only 17% of these households had actually practiced one. CONCLUSIONS: Although overall use of smoke alarms was high, certain population subgroups were less likely to have smoke alarms or to have them installed on the same floor as bedrooms. Fire escape planning, another important safety measure, was somewhat less common, and very few respondents reported having practiced a fire escape plan with the members of their household. PMID:9769771

  16. 13. GROOVED FOOTING (CONSTRUCTION KEY) EXTENDING ABOVE CEMENT FLOOR IN ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    13. GROOVED FOOTING (CONSTRUCTION KEY) EXTENDING ABOVE CEMENT FLOOR IN FIRST UNLINED SECTION BEYOND SOUTH PORTAL. - Salinas River Project, Cuesta Tunnel, Southeast of U.S. 101, San Luis Obispo, San Luis Obispo County, CA

  17. 23. Interior view of SE corner of first floor of ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    23. Interior view of SE corner of first floor of 1896 south section of building, showing windows and column. Camera pointed SE. - Puget Sound Naval Shipyard, Pattern Shop, Farragut Avenue, Bremerton, Kitsap County, WA

  18. 25. Interior view of third floor attic of 1904 middle ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    25. Interior view of third floor attic of 1904 middle section showing concrete roof and storage of wooden patterns for ship parts. - Puget Sound Naval Shipyard, Pattern Shop, Farragut Avenue, Bremerton, Kitsap County, WA

  19. ARCHITECTURAL, 777M, PHYSICS ASSEMBLY LABORATORY BUILDING, PLAN OF +13’1” AND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    ARCHITECTURAL, 777-M, PHYSICS ASSEMBLY LABORATORY BUILDING, PLAN OF +13’-1” AND +27’-0” FLOOR LEVELS (W157114) - Physics Assembly Laboratory, Area A/M, Savannah River Site, Aiken, Aiken County, SC

  20. 8. Photocopy of War Department drawing (original located at Fort ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. Photocopy of War Department drawing (original located at Fort McCoy, Wisconsin). FLOOR PLAN, PLAN NUMBER 800-1514 - Fort McCoy, Building No. T-1032, North side of South Tenth Avenue, Block 10, Sparta, Monroe County, WI

  1. Photocopy of War Department (original located at Fort McCoy, Wisconsin) ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of War Department (original located at Fort McCoy, Wisconsin) FOUNDATION, FRAMING & FLOOR PLANS, PLAN NUMBER 1100-660 - Fort McCoy, Building No. T-1039, North side of Tenth Avenue, Block 10, Sparta, Monroe County, WI

  2. Photocopy of War Department drawing (original located at Fort McCoy, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of War Department drawing (original located at Fort McCoy, Wisconsin). FLOOR PLAN & ELEVATIONS, PLAN NUMBER 700-484 - Fort McCoy, Building No. T-1003, South Side of Eleventh Avenue, Block 10, Sparta, Monroe County, WI

  3. 5. Photocopy of War Department drawing (original located at Fort ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. Photocopy of War Department drawing (original located at Fort McCoy, Wisconsin) FLOOR PLAN & ELEVATIONS, PLAN NUMBER 700-438 - Fort McCoy, Building No. T-1054, South side of South Tenth Avenue, Block 10, Sparta, Monroe County, WI

  4. Photocopy of War Department drawing (original located at Fort McCoy, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of War Department drawing (original located at Fort McCoy, Wisconsin) FLOOR PLAN & ELEVATIONS, PLAN NUMBER 700-463 - Fort McCoy, Building No. T-1022, North side of South Tenth Avenue, Block 10, Sparta, Monroe County, WI

  5. Photocopy of War Department drawing (original located at Fort McCoy, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of War Department drawing (original located at Fort McCoy, Wisconsin) FLOOR PLAN & ELEVATIONS, PLAN NUMBER 700-1240 - Fort McCoy, Building No. T-1006, South Side of South Eleventh Avenue, Block 10, Sparta, Monroe County, WI

  6. Photocopy of War Department drawing (original located at Fort McCoy, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of War Department drawing (original located at Fort McCoy, Wisconsin), FLOOR PLAN & ELEVATIONS, PLAN NUMBER 700-462 - Fort McCoy, Building No. T-1027, North side of South Tenth Avenue, Block 10, Sparta, Monroe County, WI

  7. Photocopy of War Department drawing (original located at Fort McCoy, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of War Department drawing (original located at Fort McCoy, Wisconsin). FLOOR PLANS & DETAILS, PLAN NUMBER 800-1531 - Fort McCoy, Building No. T-1005, South Side of South Eleventh Avenue, Block 10, Sparta, Monroe County, WI

  8. Photocopy of drawing (this photograph is an 8" x 10" ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of drawing (this photograph is an 8" x 10" copy of an 8" x 10" negative; 1989 original architectural drawing located at Building No. 458, NAS Pensacola, Florida) Renovation and revised office layout, Building No. 45, third floor, architectural floor plans, details and schedules, Sheet 1 of 3 - U.S. Naval Air Station, Equipment Shops & Offices, 206 South Avenue, Pensacola, Escambia County, FL

  9. Space architecture monograph series. Volume 4: Genesis 2: Advanced lunar outpost

    NASA Technical Reports Server (NTRS)

    Fieber, Joseph P.; Huebner-Moths, Janis; Paruleski, Kerry L.; Moore, Gary T. (Editor)

    1991-01-01

    This research and design study investigated advanced lunar habitats for astronauts and mission specialists on the Earth's moon. Design recommendations are based on environmental response to the lunar environment, human habitability (human factors and environmental behavior research), transportability (structural and materials system with least mass), constructability (minimizing extravehicular time), construction dependability and resilience, and suitability for NASA launch research missions in the 21st century. The recommended design uses lunar lava tubes, with construction being a combination of Space Station Freedom derived hard modules and light weight Kevlar laminate inflatable structures. The proposed habitat includes research labs and a biotron, crew quarters and crew support facility, mission control, health maintenance facility, maintenance work areas for psychological retreat, privacy, and comtemplation. Furniture, specialized equipment, and lighting are included in the analysis and design. Drawings include base master plans, construction sequencing, overall architectural configuration, detailed floor plans, sections and axonometrics, with interior perspectives.

  10. Mydriasis during Orbital Floor Fracture Reconstruction: A Novel Diagnostic and Treatment Algorithm

    PubMed Central

    Yeo, Matthew S.; Al-Mousa, Radwan; Sundar, Gangadhara; Lim, Thiam Chye

    2010-01-01

    Orbital floor fractures are the most commonly encountered traumatic fractures in the facial skeleton. Mydriasis that is detected during orbital floor fracture reconstruction may cause significant distress to surgeons, as it may be associated with sinister events such as visual loss. It is not an uncommon problem; previous studies have shown the incidence of mydriasis to be 2.1%. The combination of careful preoperative evaluation and planning, as well as specific intraoperative investigations when mydriasis is encountered, can be immensely valuable in allaying surgeons' anxiety during orbital floor fracture reconstruction. In this review article, the authors discuss the common causes of mydriasis and present a novel systematic approach to its diagnostic evaluation devised by our unit that has been successfully implemented since 2008. PMID:22132259

  11. PROCESS WATER BUILDING, TRA605. SECTIONS B, C AND D SHOW ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    PROCESS WATER BUILDING, TRA-605. SECTIONS B, C AND D SHOW RELATIONSHIP BETWEEN FLASH EVAPORATORS (ABOVE) AND SEAL AND SUMP TANKS (BELOW). BASEMENT FLOOR IS BELOW GRADE; FIRST FLOOR, ABOVE GRADE. SHIELDING TOLERANCES. BLAW-KNOX 3150-5-7, 8/1950. INL INDEX NO. 531-605-00-098-100012, REV. 2. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  12. Advanced low-floor vehicle (ALFV) specification research.

    DOT National Transportation Integrated Search

    2015-08-01

    This report details the results of research on market comparison, operational cost efficiencies, and prototype tests conducted on : a novel design for an Advanced Low Floor Vehicle (ALFV), flex-route transit bus. Section I describes how the need for ...

  13. Dark matter vs. neutrinos: the effect of astrophysical uncertainties and timing information on the neutrino floor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davis, Jonathan H., E-mail: jonathan.h.m.davis@gmail.com

    2015-03-01

    Future multi-tonne Direct Detection experiments will be sensitive to solar neutrino induced nuclear recoils which form an irreducible background to light Dark Matter searches. Indeed for masses around 6 GeV the spectra of neutrinos and Dark Matter are so similar that experiments are said to run into a neutrino floor, for which sensitivity increases only marginally with exposure past a certain cross section. In this work we show that this floor can be overcome using the different annual modulation expected from solar neutrinos and Dark Matter. Specifically for cross sections below the neutrino floor the DM signal is observable throughmore » a phase shift and a smaller amplitude for the time-dependent event rate. This allows the exclusion power to be improved by up to an order of magnitude for large exposures. In addition we demonstrate that, using only spectral information, the neutrino floor exists over a wider mass range than has been previously shown, since the large uncertainties in the Dark Matter velocity distribution make the signal spectrum harder to distinguish from the neutrino background. However for most velocity distributions it can still be surpassed using timing information, and so the neutrino floor is not an absolute limit on the sensitivity of Direct Detection experiments.« less

  14. Dark matter vs. neutrinos: the effect of astrophysical uncertainties and timing information on the neutrino floor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davis, Jonathan H.

    2015-03-09

    Future multi-tonne Direct Detection experiments will be sensitive to solar neutrino induced nuclear recoils which form an irreducible background to light Dark Matter searches. Indeed for masses around 6 GeV the spectra of neutrinos and Dark Matter are so similar that experiments are said to run into a neutrino floor, for which sensitivity increases only marginally with exposure past a certain cross section. In this work we show that this floor can be overcome using the different annual modulation expected from solar neutrinos and Dark Matter. Specifically for cross sections below the neutrino floor the DM signal is observable throughmore » a phase shift and a smaller amplitude for the time-dependent event rate. This allows the exclusion power to be improved by up to an order of magnitude for large exposures. In addition we demonstrate that, using only spectral information, the neutrino floor exists over a wider mass range than has been previously shown, since the large uncertainties in the Dark Matter velocity distribution make the signal spectrum harder to distinguish from the neutrino background. However for most velocity distributions it can still be surpassed using timing information, and so the neutrino floor is not an absolute limit on the sensitivity of Direct Detection experiments.« less

  15. Targeted Cleaning.

    ERIC Educational Resources Information Center

    Frank, David J.

    1998-01-01

    Discusses the creation of an effective carpet vacuuming program by combining area usage assessment and vacuuming requirements with a scheduling plan. Also explains vacuum cleaner suction and filtration and how it makes custodian work more efficient. A complementary article discusses creating an effective floor-maintenance plan for resilient…

  16. 44. Photograph of an original construction drawing, dated August 1927, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    44. Photograph of an original construction drawing, dated August 1927, in the possession of Facilities Planning Office, Iowa State University, Ames, Iowa. GROUND FLOOR PLAN; SHEET NO. 2 OF 10 - Dairy Industry Building, Iowa State University campus, Ames, Story County, IA

  17. 76 FR 57068 - Board Meeting; Sunshine Act Meetings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-15

    ..., 9 a.m.-1:30 p.m. PLACE: 901 N. Stuart Street, Tenth Floor, Arlington, Virginia 22203. STATUS: Open... Directors Strategic Planning President and Management Report Communications Strategy Advisory Council Next... Board of Directors Strategic Planning President and Management Report Communications Strategy Advisory...

  18. Photocopy of War Department drawing (original located at Fort McCoy, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of War Department drawing (original located at Fort McCoy, Wisconsin) FOUNDATION, FRAMING & FLOOR PLANS, PLAN NUMBER 800-1412 - Fort McCoy, Building No. T-1055, South side of South Tenth Avenue, Block 10, Sparta, Monroe County, WI

  19. Photocopy of War Department drawing (original located at Fort McCoy, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of War Department drawing (original located at Fort McCoy, Wisconsin). FLOOR & FRAMING PLANS, PLAN NUMBER 700-1204 - Fort McCoy, Building No. T-1088, Intersection of South Ninth & South Eighth Avenues, Block 10, Sparta, Monroe County, WI

  20. 11. Photocopy of War Department drawing (original located at Fort ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. Photocopy of War Department drawing (original located at Fort McCoy, Wisconsin). SECOND FLOOR PLAN, PLAN NUMBER 700-1276 - Fort McCoy, Building No. T-101, 400' North of intersection of East & West Headquarters Roads, Sparta, Monroe County, WI

  1. 10. Photocopy of War Department drawing (original located at Fort ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Photocopy of War Department drawing (original located at Fort McCoy, Wisconsin). FIRST FLOOR PLAN, PLAN NUMBER 700-1275 - Fort McCoy, Building No. T-101, 400' North of intersection of East & West Headquarters Roads, Sparta, Monroe County, WI

  2. 6. Photocopy of War Department drawing (original located at Fort ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. Photocopy of War Department drawing (original located at Fort McCoy, Wisconsin) FLOOR & CEILING PLANS AND DETAILS, PLAN NUMBER 800-1520 - Fort McCoy, Building No. T-1031, North side of South Tenth Avenue, Block 10, Sparta, Monroe County, WI

  3. Photocopy of War Department drawing (original located at Fort McCoy, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of War Department drawing (original located at Fort McCoy, Wisconsin). FLOOR PLANS, SCHEDULES & DETAILS, PLAN NUMBER 800-1537 - Fort McCoy, Building No. T-1081, North side of South Ninth Avenue, Block 10, Sparta, Monroe County, WI

  4. Dips, ramps, and rolls- Evidence for paleotopographic and syn-depositional fault control on the Western Kentucky No. 4 coal bed, tradewater formation (Bolsovian) Illinois Basin

    USGS Publications Warehouse

    Greb, S.F.; Eble, C.F.; Williams, D.A.; Nelson, W.J.

    2001-01-01

    The Western Kentucky No. 4 coal is a high-volatile B to high-volatile C bituminous coal that has been heavily mined along the southern margin of the Western Kentucky Coal Field. The seam has a reputation for rolling floor elevation. Elongate trends of floor depressions are referred to as "dips" and "rolls" by miners. Some are relatively narrow and straight to slightly curvilinear in plan view, with generally symmetric to slightly asymmetric cross-sections. Others are broader and asymmetric in section, with sharp dips on one limb and gradual, ramp-like dips on the other. Some limbs change laterally from gradual dip, to sharp dip, to offset of the coal. Lateral changes in the rate of floor elevation dip are often associated with changes in coal thickness, and in underground mines, changes in floor elevation are sometimes associated with roof falls and haulage problems. In order to test if coal thickness changes within floor depressions were associated with changes in palynology, petrography and coal quality, the coal was sampled at a surface mine across a broad. ramp-like depression that showed down-dip coal thickening. Increment samples of coal from a thick (150 cm), down-ramp and thinner (127 cm), up-ramp position at one surface mine correlate well between sample sites (a distance of 60 m) except for a single increment. The anomalous increment (31 cm) in the lower-middle part of the thick coal bed contained 20% more Lycospora orbicula spores. The rolling floor elevations noted in the study mines are inferred to have been formed as a result of pre-peat paleotopographic depressions, syn-depositional faulting, fault-controlled pre-peat paleotopography, and from compaction beneath post-depositional channels and slumps. Although the association of thick coal with linear trends and inferred faults has been used in other basins to infer syn-depositional faulting, changes in palynology within increment samples of the seam along a structural ramp in this study provide subtle evidence of faulting within a specific increment of the coal itself. The sudden increase in L. orbicula (produced by Paralycopodites) in a single increment of a down-ramp sample of the Western Kentucky No. 4 coal records the reestablishment of a rheotrophic mire following a sudden change in edaphic conditions. Paralycopodites was a colonizing lycopod, which in this case became locally abundant after the peat was well established along a fault with obvious growth during peat accumulation. Because many coal-mire plants were susceptible to sudden edaphic changes as might accompany faulting or flooding, changes in palynology would be expected in coals affected by syn-depositional faulting. ?? 2001 Elsevier Science B.V. All rights reserved.

  5. Photographic copy of plan drawing, Department of the Air Force, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photographic copy of plan drawing, Department of the Air Force, Air Defense Command Directorate of Installations, May 28, 1954, Civil Engineers Office, in possession of Selfridge Base Museum, Mt. Clemens, Michigan. FLOOR PLAN, 826-198-4 - Selfridge Field, Building No. 199, South of George Avenue between Walnut & Birch Streets, Mount Clemens, Macomb County, MI

  6. Six Basic Plan Concepts Used for California School Housing. A Sequential Development from 1900 to Today.

    ERIC Educational Resources Information Center

    California State Dept. of Education, Sacramento. Bureau of School Planning.

    A floor plan accompanies each of six chronologically arranged schemes for housing educational programs. Scheme A represents the in-line corridor plan whose main characteristics are--(1) double loaded corridors with fixed bearing walls, (2) single window walls providing minimal light and ventilation, and (3) small classrooms with fixed desks and…

  7. 7 CFR 993.107 - Floor inspection.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 8 2011-01-01 2011-01-01 false Floor inspection. 993.107 Section 993.107 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements and Orders; Fruits, Vegetables, Nuts), DEPARTMENT OF AGRICULTURE DRIED PRUNES PRODUCED IN CALIFORNIA...

  8. 7 CFR 993.505 - Floor inspection.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 8 2014-01-01 2014-01-01 false Floor inspection. 993.505 Section 993.505 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING AGREEMENTS AND ORDERS; FRUITS, VEGETABLES, NUTS), DEPARTMENT OF AGRICULTURE DRIED PRUNES PRODUCED IN CALIFORNIA...

  9. 7 CFR 993.107 - Floor inspection.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 8 2012-01-01 2012-01-01 false Floor inspection. 993.107 Section 993.107 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements and Orders; Fruits, Vegetables, Nuts), DEPARTMENT OF AGRICULTURE DRIED PRUNES PRODUCED IN CALIFORNIA...

  10. 7 CFR 993.107 - Floor inspection.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 8 2013-01-01 2013-01-01 false Floor inspection. 993.107 Section 993.107 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING AGREEMENTS AND ORDERS; FRUITS, VEGETABLES, NUTS), DEPARTMENT OF AGRICULTURE DRIED PRUNES PRODUCED IN CALIFORNIA...

  11. WINDOW WITH ORIGINAL PANELED FOLDING SHUTTERS, SECOND FLOOR FRONT ROOM, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    WINDOW WITH ORIGINAL PANELED FOLDING SHUTTERS, SECOND FLOOR FRONT ROOM, LOOKING OUT WALNUT STREET (SOUTH). NOTE ALTERED LOWER SECTION MADE CA. 1840. Compare window in PA-1436 A-37 - Kid-Chandler House, 323 Walnut Street, Philadelphia, Philadelphia County, PA

  12. HEALTH AND SAFETY BUILDING, TRA667. SOUTH AND WEST ELEVATIONS. FLOOR ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    HEALTH AND SAFETY BUILDING, TRA-667. SOUTH AND WEST ELEVATIONS. FLOOR PLAN AND ROOM DESIGNATIONS. NOTE PAIR OF ENTRY DOORS IN WEST ELEVATION FOR MEN AND WOMEN. CONCRETE T-BEAMS. F.C. TORKELSON CO. 842-MTR-667-A1, 1/1963. INL INDEX NO. 531-0667-00-851-151143, REV. 4. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  13. 6. Photographic copy of blueprint dated 1929; Henschien & McLaren, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. Photographic copy of blueprint dated 1929; Henschien & McLaren, Chicago, architects; Original in collection of Rath drawings and blueprints owned by Waterloo Community Development Board, Waterloo, Iowa; PLAN OF KILLING FLOOR IN 1929 BEEF HOUSE; CATTLE WERE SKINNED ON THE FLOOR IN PRITCHING AREA NEAR CENTER OF DRAWING - Rath Packing Company, Cooler Building-1929 Beef House, Sycamore Street between Elm & Eighteenth Streets, Waterloo, Black Hawk County, IA

  14. Collaborative Manufacturing Management in Networked Supply Chains

    NASA Astrophysics Data System (ADS)

    Pouly, Michel; Naciri, Souleiman; Berthold, Sébastien

    ERP systems provide information management and analysis to industrial companies and support their planning activities. They are currently mostly based on theoretical values (averages) of parameters and not on the actual, real shop floor data, leading to disturbance of the planning algorithms. On the other hand, sharing data between manufacturers, suppliers and customers becomes very important to ensure reactivity towards markets variability. This paper proposes software solutions to address these requirements and methods to automatically capture the necessary corresponding shop floor information. In order to share data produced by different legacy systems along the collaborative networked supply chain, we propose to use the Generic Product Model developed by Hitachi to extract, translate and store heterogeneous ERP data.

  15. First floor plan. (Also includes a door schedule and door ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    First floor plan. (Also includes a door schedule and door elevations). March Air Force Base, Riverside, California, Combat Operations Center, Combat Operations Building. By Moffatt and Nichol, Engineers, 122 West Fifth Street, Long Beach, California; for the Corps of Engineers, U.S. Army, Office of the District Engineer, Los Angeles, California. Drawing no. AW-60-02-03, sheet no. 12, approved March 1962; specifications no. OCI-62-66; D.O. series AW 1596/12, Rev. "C"; file drawer 1290. Last revised 25 August 1975. Scale one-eighth inch to one foot. 28.5x 41 inches. pencil on paper - March Air Force Base, Strategic Air Command, Combat Operations Center, 5220 Riverside Drive, Moreno Valley, Riverside County, CA

  16. A Case Study of the United States Navy’s Enterprise Resource Planning System

    DTIC Science & Technology

    2006-06-01

    incarnations, MRP-II added the capabilities of shop-floor management and distribution management activities. Later versions included the ability to manage ... finances , human resources, engineering, and project management. Enterprise Resource Planning systems were then developed as an integrated system

  17. 45. Photograph of an original construction drawing, dated August 1927, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    45. Photograph of an original construction drawing, dated August 1927, in the possession of Facilities Planning Office, Iowa State University, Ames, Iowa. FIRST FLOOR PLAN AND DETAILS; SHEET NO. 3 OF 10 - Dairy Industry Building, Iowa State University campus, Ames, Story County, IA

  18. 4. Photocopy of War Department drawing (original located at Fort ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. Photocopy of War Department drawing (original located at Fort McCoy, Wisconsin). FLOOR PLANS, PLAN NUMBER 800-1487 - Fort McCoy, Building No. T-1056, Southwest of intersection of South Tenth Avenue & South "X" Street, Block 10, Sparta, Monroe County, WI

  19. 3. Photocopy of War Department drawing (original located at Fort ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. Photocopy of War Department drawing (original located at Fort McCoy, Wisconsin) FLOOR PLAN, PLAN NUMBER 800-1424 - Fort McCoy, Building No. T-1065, Northeast of Intersection of South Ninth Avenue & South "Y" Street, Block 10, Sparta, Monroe County, WI

  20. 11. Photocopy of Sheet 3 of Building Plan R451, (USDA, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. Photocopy of Sheet 3 of Building Plan R4-51, (USDA, Forest Service, Intermountain Region, Ogden. File 7300, 'Buildings'.) Construction Details and Floor Framing. - Buffalo Guard Station, Office, U.S. Highway 20/191 at Buffalo River, Island Park, Fremont County, ID

  1. 17. Photographic copy of original remodeling drawings dated July 8, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    17. Photographic copy of original remodeling drawings dated July 8, 1988 (original sepia in plan room of Base Civil Engineer, Scott AFB) First and second floor plans - Scott Air Force Base, General Officer Quarters, 229 Birchard Street, O'Fallon, St. Clair County, IL

  2. Prevention of Labour-Associated Pelvic Floor Injuries – What is Known for Sure

    PubMed Central

    Franz, H. B.G.; Erxleben, C.; Franz, A.; Hofmann, R.

    2012-01-01

    In order to avoid pelvic floor injuries a caesarean section is on the one hand often requested by the pregnant women and, on the other hand, offered by obstetric staff. For both forms of delivery, comprehensive risk-benefit analyses should be carried out before deciding in favour of the surgical procedure. The present brief review summarizes the current evidence on the avoidance of pelvic floor injuries. PMID:26640288

  3. Physical and chemical test results of electrostatic safe flooring materials

    NASA Technical Reports Server (NTRS)

    Gompf, R. H.

    1988-01-01

    This test program was initiated because a need existed at the Kennedy Space Center (KSC) to have this information readily available to the engineer who must make the choice of which electrostatic safe floor to use in a specific application. The information, however, should be of value throughout both the government and private industry in the selection of a floor covering material. Included are the test results of 18 floor covering materials which by test evaluation at KSC are considered electrostatically safe. Tests were done and/or the data compiled in the following areas: electrostatics, flammability, hypergolic compatibility, outgassing, floor type, material thickness, and available colors. Each section contains the test method used to gather the data and the test results.

  4. Comparisons of the Impact Responses of a 1/5-Scale Model and a Full-Scale Crashworthy Composite Fuselage Section

    NASA Technical Reports Server (NTRS)

    Jackson, Karen E.; Fasanella, Edwin L.; Lyle, Karen H.

    2003-01-01

    A 25-fps vertical drop test of a 1/5-scale model composite fuselage section was conducted to replicate a previous test of a full-scale fuselage section. The purpose of the test was to obtain experimental data characterizing the impact response of the 1/5-scale model fuselage section for comparison with the corresponding full-scale data. This comparison is performed to assess the scaling procedures and to determine if scaling effects are present. For the drop test, the 1/5-scale model fuselage section was configured in a similar manner as the full-scale section, with lead masses attached to the floor through simulated seat rails. Scaled acceleration and velocity responses are compared and a general assessment of structural damage is made. To further quantify the data correlation, comparisons of the average acceleration data are made as a function of floor location and longitudinal position. Also, the percentage differences in the velocity change (area under the acceleration curve) and the velocity change squared (proportional to kinetic energy) are compared as a function of floor location. Finally, correlation coefficients are calculated for corresponding 1/5- and full-scale data channels and these values are plotted versus floor location. From a scaling perspective, the differences between the 1/5- and full-scale tests are relatively small, indicating that appropriate scaling procedures were used in fabricating the test specimens and in conducting the experiments. The small differences in the scaled test data are attributed to minor scaling anomalies in mass, potential energy, and impact attitude.

  5. Guidelines for Interpretive Building Design.

    ERIC Educational Resources Information Center

    Manly, Richard J., Ed.

    This booklet is intended to assist those planning nature centers to choose building designs appropriate for intended purposes. The publication presents a set of general interpretive building-site and design considerations compiled over years of experience in nature center design. These generalizations are complemented by examples of floor plans,…

  6. 14. Photographic copy of sepia of original construction drawing dated ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    14. Photographic copy of sepia of original construction drawing dated September 15, 1938 (Original sepia in plan room of Base Civil Engineer, Scott AFB) First and second floor plans - Scott Air Force Base, General Officer Quarters, 229 Birchard Street, O'Fallon, St. Clair County, IL

  7. Photocopy of drawing (this photograph is an 8" x 10" ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of drawing (this photograph is an 8" x 10" copy of an 8" x 10" negative; 1975 architectural drawing located at NAS Pensacola, Florida, Building No. 458) MECHANICAL PLAN, ELECTRICAL PLAN, FLOOR PLAN AND DETAILS FOR ALTERATIONS TO BUILDING NO. 322, SHEET 1 OF 1. - U.S. Naval Air Station, YMCA Building, West Avenue, Pensacola, Escambia County, FL

  8. Pedestrian mobile mapping system for indoor environments based on MEMS IMU and range camera

    NASA Astrophysics Data System (ADS)

    Haala, N.; Fritsch, D.; Peter, M.; Khosravani, A. M.

    2011-12-01

    This paper describes an approach for the modeling of building interiors based on a mobile device, which integrates modules for pedestrian navigation and low-cost 3D data collection. Personal navigation is realized by a foot mounted low cost MEMS IMU, while 3D data capture for subsequent indoor modeling uses a low cost range camera, which was originally developed for gaming applications. Both steps, navigation and modeling, are supported by additional information as provided from the automatic interpretation of evacuation plans. Such emergency plans are compulsory for public buildings in a number of countries. They consist of an approximate floor plan, the current position and escape routes. Additionally, semantic information like stairs, elevators or the floor number is available. After the user has captured an image of such a floor plan, this information is made explicit again by an automatic raster-to-vector-conversion. The resulting coarse indoor model then provides constraints at stairs or building walls, which restrict the potential movement of the user. This information is then used to support pedestrian navigation by eliminating drift effects of the used low-cost sensor system. The approximate indoor building model additionally provides a priori information during subsequent indoor modeling. Within this process, the low cost range camera Kinect is used for the collection of multiple 3D point clouds, which are aligned by a suitable matching step and then further analyzed to refine the coarse building model.

  9. Photocopy of photograph (original negative located in LBNL Photo Lab ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of photograph (original negative located in LBNL Photo Lab Collection). March 2005. STAIRWAY BETWEEN MAIN FLOOR OF MAGNET ROOM AND SECOND FLOOR OF OFFICE-AND-SHOP SECTION, BEVATRON - University of California Radiation Laboratory, Bevatron, 1 Cyclotron Road, Berkeley, Alameda County, CA

  10. 55. TOP (4TH) FLOOR OF 187380 WING LOOKING NORTH, WEST ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    55. TOP (4TH) FLOOR OF 1873-80 WING LOOKING NORTH, WEST SIDE. NOTE SECTION, LEFT SIDE, MIDDLEGROUND, WHERE SMALL HIGH WINDOWS INDICATE POINT AT WHICH 1852 WING JOINS THIS WING. - Boston Manufacturing Company, 144-190 Moody Street, Waltham, Middlesex County, MA

  11. 18. VIEW OF THE CEILING, THE PIPING TRANSPORTED CHEMICALS FROM ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    18. VIEW OF THE CEILING, THE PIPING TRANSPORTED CHEMICALS FROM A CHEMICAL PREPARATION ROOM ON THE SECOND FLOOR TO THE FIRST FLOOR PROCESS AREAS. (6/12/73) - Rocky Flats Plant, Plutonium Recovery & Fabrication Facility, North-central section of plant, Golden, Jefferson County, CO

  12. 7 CFR 993.107 - Floor inspection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Floor inspection. 993.107 Section 993.107 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... containers. Effective Date Note: At 70 FR 30613, May 27, 2005, § 993.107 was suspended indefinitely. ...

  13. Light-frame wall and floor systems : analysis and performance

    Treesearch

    G. Sherwood; R. C. Moody

    1989-01-01

    This report describes methods of predicting the performance of light-frame wood structures with emphasis on floor and wall systems. Methods of predicting structural performance, fire safety, and environmental concerns including thermal, moisture, and acoustic performance are addressed in the three major sections.

  14. 13. Photocopy of 1920 drawing titled: BUILDING 78, 3RD FLOOR ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    13. Photocopy of 1920 drawing titled: BUILDING 78, 3RD FLOOR BALCONY AND FIRE ESCAPES, including plans for skylight and North Elevation. HABS photograph is an 8x10' contact print made from a high contrast negative of an enlargement made from microfiche. Original is in the collection of Department of Public Works, Puget Sound Naval Shipyard, Bremerton, WA. - Puget Sound Naval Shipyard, Administration Building, Farragut Avenue, Bremerton, Kitsap County, WA

  15. Green Giant.

    ERIC Educational Resources Information Center

    Polo, Marco

    2003-01-01

    Details the design of the Bahen Centre for Information Technology at the University of Toronto, particularly its emphasis on "green," or sustainable, design. Includes floor plans and photographs. (EV)

  16. RECOMMENDATIONS FOR SAMPLING OF TANK 19 IN F TANK FARM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harris, S.; Shine, G.

    2009-12-14

    Representative sampling is required for characterization of the residual material in Tank 19 prior to operational closure. Tank 19 is a Type IV underground waste storage tank located in the F-Tank Farm. It is a cylindrical-shaped, carbon steel tank with a diameter of 85 feet, a height of 34.25 feet, and a working capacity of 1.3 million gallons. Tank 19 was placed in service in 1961 and initially received a small amount of low heat waste from Tank 17. It then served as an evaporator concentrate (saltcake) receiver from February 1962 to September 1976. Tank 19 also received the spentmore » zeolite ion exchange media from a cesium removal column that once operated in the Northeast riser of the tank to remove cesium from the evaporator overheads. Recent mechanical cleaning of the tank removed all mounds of material. Anticipating a low level of solids in the residual waste, Huff and Thaxton [2009] developed a plan to sample the waste during the final clean-up process while it would still be resident in sufficient quantities to support analytical determinations in four quadrants of the tank. Execution of the plan produced fewer solids than expected to support analytical determinations in all four quadrants. Huff and Thaxton [2009] then restructured the plan to characterize the residual separately in the North and the South regions: two 'hemispheres.' This document provides sampling recommendations to complete the characterization of the residual material on the tank bottom following the guidance in Huff and Thaxton [2009] to split the tank floor into a North and a South hemisphere. The number of samples is determined from a modification of the formula previously published in Edwards [2001] and the sample characterization data for previous sampling of Tank 19 described by Oji [2009]. The uncertainty is quantified by an upper 95% confidence limit (UCL95%) on each analyte's mean concentration in Tank 19. The procedure computes the uncertainty in analyte concentration as a function of the number of samples, and the final number of samples is determined when the reduction in the uncertainty from an additional sample no longer has a practical impact on results. The characterization of the full suite of analytes in the North and South hemispheres is currently supported by a single Mantis rover sample in each hemisphere. A floor scrape sample was obtained from a compact region near the center riser slightly in the South hemisphere and has been analyzed for a shortened list of key analytes. There is not enough additional material from the floor scrape sample material for completing the full suite of constituents. No floor scrape samples have been previously taken from the North hemisphere. The criterion to determine the number of additional samples was based on the practical reduction in the uncertainty when a new sample is added. This was achieved when five additional samples are obtained. In addition, two archived samples will be used if a contingency such as failing to demonstrate the comparability of the Mantis samples to the floor scrape samples occurs. To complete sampling of the Tank 19 residual floor material, four additional samples should be taken from the North hemisphere and four additional samples should be taken from the South hemisphere. One of the samples from each hemisphere will be archived in case of need. Three of the four additional samples from each hemisphere will be analyzed. Once the results are available, differences between the Mantis and three floor scrape sample results will be evaluated. If there are no statistically significant analyte concentration differences between the Mantis and floor scrape samples, those results will be combined and then UCL95%s will be calculated. If the analyte concentration differences between the Mantis and floor scrape samples are statistically significant, the UCL95%s will be calculated without the Mantis sample results. If further reduction in the upper confidence limits is needed and can be achieved by the addition of the archived samples, they will be analyzed and included in the statistical computations. Initially the analyte concentrations in the residual material on the floor of Tank 19 will be determined separately in the North and the South hemispheres. However, if final sampling results show that differences between the North and South samples are consistent within sampling variation, then the final computations can be based on consolidating all sample results from the tank floor. Recommended locations may be subject to physical tank access and sampling constraints for the additional samples. The recommendations have been discussed in Section 4 and are based on partitioning the Tank 19 floor into an inner and an outer ring and six 60{sup o} sectors depicted in Figure 1. The location of the border between the inner and outer rings is based on dividing the residual material into two approximately equal volumes.« less

  17. How to Manage an Extensive Laserdisk Installation: The Texas A&M Experience.

    ERIC Educational Resources Information Center

    Tucker, Sandra L.; And Others

    1988-01-01

    The second of two articles on the acquisition and implementation of a large laserdisk service at Texas A&M University covers equipment and supplies, future plans, service, staffing, training of staff and patrons, and statistics. A floor plan, user instruction sheet, and news release are included. (MES)

  18. 43. Photograph of an original construction drawing, dated October 1927, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    43. Photograph of an original construction drawing, dated October 1927, in the possession of Facilities Planning Office, Iowa State University, Ames, Iowa. GROUND FLOOR PLAN, REFRIGERATION LAYOUT AND DETAILS; SHEET R-1 OF 1 SHEET - Dairy Industry Building, Iowa State University campus, Ames, Story County, IA

  19. Planning Guidelines for Primary Schools, Issue 1.

    ERIC Educational Resources Information Center

    Department of Education and Science, Tullamore (Ireland). Planning and Building Unit.

    This planning guide, reflecting recent changes in the educational system in Ireland, offers guidelines for designing primary schools that need to provide additional space for the growing range of teaching and support services. It addresses increased sizes of general purpose rooms, extra floor area provision for classroom storage, administration,…

  20. Photograph of original drawing (original in possession of National Passenger ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photograph of original drawing (original in possession of National Passenger Railroad Corporation). STATION BUILDING: Basement Floor Plan / Alterations and Additions (dated 5/1913). Proposed plan - not used - North Philadelphia Station, 2900 North Broad Street, on northwest corner of Broad Street & Glenwood Avenue, Philadelphia, Philadelphia County, PA

  1. 18. Photographic copy of original remodeling drawings dated July 8, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    18. Photographic copy of original remodeling drawings dated July 8, 1988 (original sepia in plan room of Base Civil Engineer, Scott AFB) First and second floor demolition and framing plan - Scott Air Force Base, General Officer Quarters, 229 Birchard Street, O'Fallon, St. Clair County, IL

  2. Survey Available Computer Software for Automated Production Planning and Inventory Control, and Software and Hardware for Data Logging and Monitoring Shop Floor Activities

    DTIC Science & Technology

    1993-08-01

    pricing and sales, order processing , and purchasing. The class of manufacturing planning functions include aggregate production planning, materials...level. I Depending on the application, each control level will have a number of functions associated with it. For instance, order processing , purchasing...include accounting, sales forecasting, product costing, pricing and sales, order processing , and purchasing. The class of manufacturing planning functions

  3. 7 CFR 993.505 - Floor inspection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Floor inspection. 993.505 Section 993.505 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... packing containers for later packaging. Effective Date Note: At 70 FR 30613, May 27, 2005, § 993.505 was...

  4. 7 CFR 2902.39 - Floor strippers.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 15 2011-01-01 2011-01-01 false Floor strippers. 2902.39 Section 2902.39 Agriculture Regulations of the Department of Agriculture (Continued) OFFICE OF ENERGY POLICY AND NEW USES, DEPARTMENT OF... mechanical assistance. (b) Minimum biobased content. The preferred procurement product must have a minimum...

  5. 18. VIEW OF THE SECOND FLOOR OF BUILDING 707. AIR ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    18. VIEW OF THE SECOND FLOOR OF BUILDING 707. AIR EXHAUST FANS ARE USED TO MAINTAIN PRESSURE DIFFERENTIALS WITHIN THE BUILDING. (5/70) - Rocky Flats Plant, Plutonium Manufacturing Facility, North-central section of Plant, just south of Building 776/777, Golden, Jefferson County, CO

  6. 76 FR 7098 - Dealer Floor Plan Pilot Program

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-09

    ... inventory, including but not limited to automobiles, motorcycles, boats (including boat trailers..., including but not limited to automobiles, motorcycles, boats (including boat trailers), recreational...

  7. Shadows of Previous Days - a Journey Into Digital Reconstruction

    NASA Astrophysics Data System (ADS)

    Linsinger, S.

    2013-02-01

    In November 2011 the listed state rooms on the second floor of the Viennese city palace Am Hof 2 were largely destroyed by fire. The historic rooms on the ground floor, the monumental, marble-clad bank service hall and the wood-panelled club rooms all suffered badly from other consequences of the fire such as water and smoke damage. Planning and concept development for the reconstruction of the interior elements made of various materials was carried out be a team of specialist conservators in close collaboration with the Bundesdenkmalamt (Federal Monuments Office). This paper will confine itself to describing the planning, concept development and production of the sample areas for the wooden elements although in practice concept development for all materials ran parallel.

  8. Vibrating vaginal balls to improve pelvic floor muscle performance in women after childbirth: a protocol for a randomised controlled feasibility trial.

    PubMed

    Oblasser, Claudia; McCourt, Christine; Hanzal, Engelbert; Christie, Janice

    2016-04-01

    This paper presents a feasibility trial protocol the purpose of which is to prepare for a future randomised controlled trial to determine the effectiveness of vibrating vaginal pelvic floor training balls for postpartum pelvic floor muscle rehabilitation. Vibrating vaginal pelvic floor training balls are available in Austria to enhance women's pelvic floor muscles and thus prevent or treat urinary incontinence and other pelvic floor problems following childbirth. Nonetheless, there is currently little empirical knowledge to substantiate their use or assess their relative effectiveness in comparison to current standard care, which involves pelvic floor muscle exercises. Single blind, randomised controlled feasibility trial with two parallel groups. It is planned to recruit 56 postpartum women in Vienna, who will be randomised into one of two intervention groups to use either vibrating vaginal balls or a comparator pelvic floor muscle exercises for 12 weeks. As this is a feasibility study, study design features (recruitment, selection, randomisation, intervention concordance, data collection methods and tools) will be assessed and participants' views and experiences will be surveyed. Tested outcome measures, collected before and after the intervention, will be pelvic floor muscle performance as reported by participants and measured by perineometry. Descriptive and inferential statistics and content analysis will serve the preparation of the future trial. The results of this feasibility trial will inform the design and conduct of a full randomised controlled trial and provide insight into the experiences of women regarding the interventions and study participation. © 2015 John Wiley & Sons Ltd.

  9. 129. Photographic copy of drawing (24 June 1963, original drawing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    129. Photographic copy of drawing (24 June 1963, original drawing in Archives, Public Affairs Departmentm, Sears Merchandise Group, Hoffman Estates, Illinois). Swain and Meyers, Inc. 1/4 inch to one foot. Partial floor plan illustrating the layout of the large package handling area. Tables and equipment not present at the time of the survey are shown. SECOND FLOOR, SECTON B - Sears Roebuck & Company Mail Order Plant, Merchandise Building, 924 South Homan Avenue, Chicago, Cook County, IL

  10. 35. SECOND FLOOR WEST ROOM LOOKING NORTH. The two trusses ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    35. SECOND FLOOR WEST ROOM LOOKING NORTH. The two trusses above this room date from 1812. They differ from the 1755 salvaged trusses in that they are made of pine rather than poplar, their numbering system differs, and they do not have pockets for joists. These two trusses were added to extend the plan of the building when it was re-erected in 1812. - Twelfth Street Meeting House, 20 South Twelfth Street, Philadelphia, Philadelphia County, PA

  11. 30 CFR 822.11 - Essential hydrologic functions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false Essential hydrologic functions. 822.11 Section... IN ALLUVIAL VALLEY FLOORS § 822.11 Essential hydrologic functions. (a) The operator of a surface coal... throughout the mining and reclamation process the essential hydrologic functions of an alluvial valley floor...

  12. 29 CFR 1910.68 - Manlifts.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... floor to floor. (6) Rated speed. Rated speed is the speed for which the device is designed and installed... purpose of this section is to provide reasonable safety for life and limb. (3) Design requirements. All... meet the design requirements of the “American National Safety Standard for Manlifts ANSI A90.1-1969...

  13. 29 CFR 1910.68 - Manlifts.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... floor to floor. (6) Rated speed. Rated speed is the speed for which the device is designed and installed... purpose of this section is to provide reasonable safety for life and limb. (3) Design requirements. All... meet the design requirements of the “American National Safety Standard for Manlifts ANSI A90.1-1969...

  14. INTERIOR PHOTO OF HOT PILOT PLANT SECOND FLOOR WITH SOUTH ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    INTERIOR PHOTO OF HOT PILOT PLANT SECOND FLOOR WITH SOUTH SECTION OF SHIELDED CAVE IN FOREGROUND (CPP-640) LOOKING NORTHWEST. INL PHOTO NUMBER HD-54-40-1. Mike Crane, Photographer, 7/2006 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID

  15. 12. Interior view of first floor aisle in 1922 north ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    12. Interior view of first floor aisle in 1922 north section. Camera is pointed south from rear of building. Post at far left is also seen on right in photo WA-116-A-11. - Puget Sound Naval Shipyard, Pattern Shop, Farragut Avenue, Bremerton, Kitsap County, WA

  16. 29 CFR 1926.754 - Structural steel assembly.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... connectors on composite floors, roofs and bridge decks. When shear connectors are used in construction of composite floors, roofs and bridge decks, employees shall lay out and install the shear connectors after the... requirements of paragraph (e)(3)(i) of this section. (4) Decking gaps around columns. Wire mesh, exterior...

  17. 29 CFR 1926.754 - Structural steel assembly.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... connectors on composite floors, roofs and bridge decks. When shear connectors are used in construction of composite floors, roofs and bridge decks, employees shall lay out and install the shear connectors after the... requirements of paragraph (e)(3)(i) of this section. (4) Decking gaps around columns. Wire mesh, exterior...

  18. 29 CFR 1926.754 - Structural steel assembly.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... connectors on composite floors, roofs and bridge decks. When shear connectors are used in construction of composite floors, roofs and bridge decks, employees shall lay out and install the shear connectors after the... requirements of paragraph (e)(3)(i) of this section. (4) Decking gaps around columns. Wire mesh, exterior...

  19. 9 CFR 91.26 - Concrete flooring.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 9 Animals and Animal Products 1 2014-01-01 2014-01-01 false Concrete flooring. 91.26 Section 91.26 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE EXPORTATION AND IMPORTATION OF ANIMALS (INCLUDING POULTRY) AND ANIMAL PRODUCTS INSPECTION AND HANDLING OF LIVESTOCK FOR EXPORTATION Inspection of...

  20. 9 CFR 91.26 - Concrete flooring.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 9 Animals and Animal Products 1 2013-01-01 2013-01-01 false Concrete flooring. 91.26 Section 91.26 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE EXPORTATION AND IMPORTATION OF ANIMALS (INCLUDING POULTRY) AND ANIMAL PRODUCTS INSPECTION AND HANDLING OF LIVESTOCK FOR EXPORTATION Inspection of...

  1. 9 CFR 91.26 - Concrete flooring.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 9 Animals and Animal Products 1 2012-01-01 2012-01-01 false Concrete flooring. 91.26 Section 91.26 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE EXPORTATION AND IMPORTATION OF ANIMALS (INCLUDING POULTRY) AND ANIMAL PRODUCTS INSPECTION AND HANDLING OF LIVESTOCK FOR EXPORTATION Inspection of...

  2. 29 CFR 1926.856 - Removal of walls, floors, and material with equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....856 Section 1926.856 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Demolition § 1926... the imposed load. (b) Floor openings shall have curbs or stop-logs to prevent equipment from running...

  3. 29 CFR 1926.856 - Removal of walls, floors, and material with equipment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ....856 Section 1926.856 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Demolition § 1926... the imposed load. (b) Floor openings shall have curbs or stop-logs to prevent equipment from running...

  4. Dance floor mechanical properties and dancer injuries in a touring professional ballet company.

    PubMed

    Hopper, Luke S; Allen, Nick; Wyon, Matthew; Alderson, Jacqueline A; Elliott, Bruce C; Ackland, Timothy R

    2014-01-01

    The mechanical properties of the floors used by dancers have often been suggested to be associated with injury, yet limited etiological evidence is available to support this hypothesis. The dance floors at three theatres regularly used by a touring professional ballet company were mechanically quantified with the aim of comparing floor properties with injury incidence in dancers. Cross sectional. Test points on the floors were quantified in accordance with European Sports Surface Standard protocols for force reduction. Injuries and associated variables occurring within the ballet company dancers during activity on the three floors were recorded by the company's medical staff. An injury was recorded if a dancer experienced an incident that restricted the dancer from performing all normal training or performance activities for a 24 h period. Injuries were delimited to those occurring in the lower limbs or lumbar region during non-lifting tasks. Floor construction varied between venues and a range of floor mechanical properties were observed. None of the floors complied with the range of force reduction values required by the European Sport Surface Standards. The highest injury rate was observed on the floor with the greatest variability of force reduction magnitudes. No difference in injury frequency was observed between the venues with the highest and lowest mean force reduction magnitudes. Professional dancers can be required to perform on floors that may be inadequate for safe dance practice. Intra-floor force reduction variability may have a stronger association with injury risk than mean floor force reduction magnitude. Copyright © 2013 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  5. The installation of a sub sea floor observatory using the sea floor drill rig MeBo

    NASA Astrophysics Data System (ADS)

    Wefer, G.; Freudenthal, T.; Kopf, A.

    2012-04-01

    Sea floor drill rigs that can be deployed from standard research vessels are bridging the gap between dedicated drill ships that are used for deep drillings in the range of several hundred meters below sea floor and conventional sampling tools like gravity corers, piston corer or dredges that only scratch the surface of the sea floor. A major advantage of such robotic drill rigs is that the drilling action is conducted from a stable platform at the sea bed independent of any ship movements due to waves, wind or currents. At the MARUM Center for Marine Environmental Sciences at the University of Bremen we developed the sea bed drill rig MeBo that can be deployed from standard research vessels. The drill rig is deployed on the sea floor and controlled from the vessel. Drilling tools for coring the sea floor down to 70 m can be stored on two magazines on the rig. A steel-armoured umbilical is used for lowering the rig to the sea bed in water depths up to 2000 m in the present system configuration. It was successfully operated on ten expeditions since 2005 and drilled more than 1000 m in different types of geology including hemipelagic mud, glacial till as well as sedimentary and crystalline rocks. MeBo boreholes be equipped with sensors and used for long term monitoring are planned. Depending on the scientific demands, a MeBoCORK monitoring system will allow in situ measurements of eg. temperature and pressure. The "MeBoCORK" will be equipped with data loggers and data transmission interface for reading out the collected data from the vessel. By additional payload installation on the MeBoCORK with an ROV it will be possible to increase the energy capacity as well as to conduct fluid sampling in the bore hole for geochemical analyses. It is planned to install a prototype of this additional payload with the MARUM ROV QUEST4000M during the following R/V SONNE cruise in July 2012.

  6. Knowledge of the pelvic floor in nulliparous women

    PubMed Central

    Neels, Hedwig; Wyndaele, Jean-Jacques; Tjalma, Wiebren A. A.; De Wachter, Stefan; Wyndaele, Michel; Vermandel, Alexandra

    2016-01-01

    [Purpose] Proper pelvic floor function is important to avoid serious dysfunctions including incontinence, prolapse, and sexual problems. The current study evaluated the knowledge of young nulliparous women about their pelvic floor and identified what additional information they wanted. [Subjects and Methods] In this cross-sectional survey, a validated, 36 item questionnaire was distributed to 212 nulliparous women. The questionnaire addressed demography, pelvic floor muscles, pelvic floor dysfunction, and possible information sources. Descriptive statistics were generated for all variables. Stability and validity testing were performed using Kappa statistics and intra class correlation coefficients to define agreement for each question. The study was approved by the ethics Committee (B300201318334). [Results] Using a VAS scale (0 to 10), the women rated their knowledge about the pelvic floor as a mean of 2.4 (SD 2.01). A total of 93% of the women were insufficiently informed and requested more information; 25% had concerns about developing urinary incontinence, and 14% about fecal incontinence. Many of the women were unaware what pelvic floor training meant. [Conclusion] There was a significant lack of knowledge about pelvic floor function among nulliparous women. The majority of nulliparous women expressed a need for education, which might offer a way to reduce dysfunction. PMID:27313364

  7. Effects of roughness and compressibility of flooring on cow locomotion.

    PubMed

    Rushen, J; de Passillé, A M

    2006-08-01

    We examined the effects of roughness and degree of compressibility of flooring on the locomotion of dairy cows. We observed 16 cows walking down specially constructed walkways with materials that differed in surface roughness and degree of compressibility. Use of a commercially available soft rubber flooring material decreased slipping, number of strides, and time to traverse the corridor. These effects were most apparent at difficult sections of the corridor, such as at the start, at a right-angle turn, and across a gutter. Covering the walkway with a thin layer of slurry increased frequency of slipping, number of strides, and time taken to traverse the walkway. Effects of adding slurry were not overcome by increasing surface roughness or compressibility. Placing more compressible materials under a slip-resistant material reduced the time and number of steps needed to traverse the corridor but did not reduce slips, and the effects on cow locomotion varied nonlinearly with the degree of compressibility of the floor. Use of commercially available rubber floors improved cow locomotion compared with concrete floors. However, standard engineering measures of the floor properties may not predict effects of the floor on cow behavior well. Increasing compressibility of the flooring on which cows walk, independently of the roughness of the surface, can improve cow locomotion.

  8. Librarians as Interior Designers: The Icing on the Cake (Profile of a Community College LRC: Palomar College).

    ERIC Educational Resources Information Center

    Arnsan, Dan

    1985-01-01

    Describes how staff at Palomar College Library participated in planning the interior of the library building in areas such as designing the floor plans, writing furniture specifications, choosing colors, and making structural changes in the facility. Offers advice for other librarians participating in building projects. (DMM)

  9. 11. Photographic copy of construction drawing, dated July 29, 1932, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. Photographic copy of construction drawing, dated July 29, 1932, Construction Division Office of the Quartermaster General, in possession of Selfridge Base Museum, Mt. Clemens, Michigan. PLAN 625-2511 SDO 139 (FLOOR PLANS) - Selfridge Field, Building Nos. 246 & 253, 246 Birch Street & 253 Wagner Street, Mount Clemens, Macomb County, MI

  10. 10. Photographic copy of construction drawing, dated February 6, 1931, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Photographic copy of construction drawing, dated February 6, 1931, Construction Division Office of the Quartermaster General, in possession of Selfridge Base Museum, Mt. Clemens, Michigan. FOUNDATION, FIRST FLOOR PLANS, ELEVATIONS, DETAILS, PLAN NO. 6658-130. - Selfridge Field, Building No. 121, Wilbur Wright Avenue west of Ash Street, Mount Clemens, Macomb County, MI

  11. Make the Right Choices When You Plan that New Gym.

    ERIC Educational Resources Information Center

    Reecer, Marcia

    1988-01-01

    Emphasizes the need for intimate faculty involvement in planning a new school gymnasium. Once an architect has been chosen, planners should consider flexibility for newer sports and other functions and be aware of choices regarding size, flooring, use of dividers, and maintenance. Because gym requirements vary by region and school system, careful…

  12. 51. Photograph of an original construction drawing, dated August 1927, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    51. Photograph of an original construction drawing, dated August 1927, in the possession of Facilities planning Office, Iowa State University, Ames, Iowa. GROUND FLOOR PLAN, MECHANICAL FAN ROOM LAYOUT, ELECTRICAL WIRING DIAGRAM, RADIATOR, FANS 1 & 2, DETAILS; SHEET NO. 202 OF 3 - Dairy Industry Building, Iowa State University campus, Ames, Story County, IA

  13. 14. Photographic copy of construction drawing, Trowbridge & Livingston, Architects, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    14. Photographic copy of construction drawing, Trowbridge & Livingston, Architects, New York, 22 August 1941 (original print located at F.E. Warren Air Force Base Archives, Cheyenne, Wyoming). FIRST FLOOR PLAN AND CELLAR PLAN. - Fort David A. Russell, Red Cross Building, Third Street between Randall Avenue & Tenth Cavalry Avenue, Cheyenne, Laramie County, WY

  14. Basin-floor Lake Bonneville stratigraphic section as revealed in paleoseismic trenches at the Baileys Lake site, West Valley fault zone, Utah

    USGS Publications Warehouse

    Hylland, Michael D.; DuRoss, Christopher B.; McDonald, Greg N.; Olig, Susan S.; Oviatt, Charles G.; Mahan, Shannon; Crone, Anthony J.; Personius, Stephen

    2012-01-01

     Recent paleoseismic trenching on the Granger fault of the West Valley fault zone in Salt Lake County, Utah, exposed a nearly complete section of late Pleistocene Lake Bonneville deposits, and highlights challenges related to accurate interpretation of basin-floor stratigraphy in the absence of numerical age constraints. We used radiocarbon and luminescence dating as well as ostracode biostratigraphy to provide chronostratigraphic control on the Lake Bonneville section exposed at the Baileys Lake trench site. The fault trenches exposed folded and faulted pre- to post- Bonneville sediments, including about 0.7 m of pre-Bonneville wetland/fluvial-marsh deposits, a nearly complete Bonneville section 2.5–4.0 m thick, and 0.4–1.0 m of post-Bonneville deposits consisting primarily of loess with minor scarp-derived colluvium. The relatively thin Bonneville section compares favorably with basin-floor Bonneville sections documented in boreholes and seismic reflection profiles beneath Great Salt Lake. Distinctive features of the Bonneville section at the Baileys Lake site include a sequence of turbidites in the upper part of the Bonneville transgressive deposits, evidence for an earthquake during Provo-shoreline time that disturbed lake-bottom sediments and destroyed any stratigraphic signature of the Bonneville Flood, tufa deposition associated with Gilbert-phase shoreline transgression, and stratigraphic evidence for two Gilbert transgressions across the site.

  15. Geological Mapping of Impact Melt Deposits at Lunar Complex Craters: New Insights into Morphological Diversity, Distribution and the Cratering Process

    NASA Astrophysics Data System (ADS)

    Dhingra, D.; Head, J. W., III; Pieters, C. M.

    2014-12-01

    We have completed high resolution geological mapping of impact melt deposits at the young lunar complex craters (<1 billion years) Copernicus, Jackson and Tycho using data from recent missions. Crater floors being the largest repository of impact melt, we have mapped their morphological diversity expressed in terms of varied surface texture, albedo, character and occurrence of boulder units as well as relative differences in floor elevation. Examples of wall and rim impact melt units and their relation to floor units have also been mapped. Among the distinctive features of these impact melt deposits are: 1) Impact Melt Wave Fronts: These are extensive (sometimes several kilometers in length) and we have documented their occurrence and distribution in different parts of the crater floor at Jackson and Tycho. These features emphasize melt mobility and style of emplacement during the modification stage of the craters. 2) Variations in Floor Elevations: Spatially extensive and coherent sections of crater floors have different elevations at all the three craters. The observed elevation differences could be caused by subsidence due to cooling of melt and/or structural failure, together with a contribution from regional slope. 3) Melt-Covered Megablocks: We also observe large blocks/rock-fragments (megablocks) covered in impact melt, which could be sections of collapsed wall or in some cases, subdued sections of central peaks. 4) Melt-Covered Central Peaks: Impact melt has also been mapped on the central peaks but varies in spatial extent among the craters. The presence of melt on peaks must be taken into account when interpreting peak mineralogy as exposures of deeper crust. 5) Boulder Distribution: Interesting trends are observed in the distribution of boulder units of various sizes; some impact melt units have spatially extensive boulders, while boulder distribution is very scarce in other units on the floor. We interpret these distributions to be influenced by a) the differential collapse of the crater walls during the modification stage, and b) the amount of relative melt volume retained in different parts of the crater floor. These observations provide important documentation of the morphological diversity and better understanding of the emplacement and final distribution of impact melt deposits.

  16. SOUTH FIRE HOUSE, FIRST FLOOR FRAMING AND DETAILS, BUILDING NO. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    SOUTH FIRE HOUSE, FIRST FLOOR FRAMING AND DETAILS, BUILDING NO. 726 (Also includes a foundation plan). Navy Yard, Mare Island, CA. Y & D (Yards & Docks) drawing no. 282852, approved October 22, 194_ (year not given); file no. 726-S-1; stamped "Record drawing to accompany technical report on contract no. 4550, project no. 16." Various scales. 71 cm x 86 cm. Ink on vellum. - Mare Island Naval Shipyard, South Fire Station, Railroad Avenue near Eighteenth Street, Vallejo, Solano County, CA

  17. When the library is located in prime real estate: a case study on the loss of space from the Duke University Medical Center Library and Archives.

    PubMed

    Thibodeau, Patricia L

    2010-01-01

    The Duke University Medical Center Library and Archives is located in the heart of the Duke Medicine campus, surrounded by Duke Hospital, ambulatory clinics, and numerous research facilities. Its location is considered prime real estate, given its adjacency to patient care, research, and educational activities. In 2005, the Duke University Library Space Planning Committee had recommended creating a learning center in the library that would support a variety of educational activities. However, the health system needed to convert the library's top floor into office space to make way for expansion of the hospital and cancer center. The library had only five months to plan the storage and consolidation of its journal and book collections, while working with the facilities design office and architect on the replacement of key user spaces on the top floor. Library staff worked together to develop plans for storing, weeding, and consolidating the collections and provided input into renovation plans for users spaces on its mezzanine level. The library lost 15,238 square feet (29%) of its net assignable square footage and a total of 16,897 (30%) gross square feet. This included 50% of the total space allotted to collections and over 15% of user spaces. The top-floor space now houses offices for Duke Medicine oncology faculty and staff. By storing a large portion of its collection off-site, the library was able to remove more stacks on the remaining stack level and convert them to user spaces, a long-term goal for the library. Additional space on the mezzanine level had to be converted to replace lost study and conference room spaces. While this project did not match the recommended space plans for the library, it underscored the need for the library to think creatively about the future of its facility and to work toward a more cohesive master plan.

  18. 9 CFR 91.14 - Ports of embarkation and export inspection facilities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... paragraph (b) of this section, shall meet the following requirements: (1) Materials. Floors of pens, alleys, and chutes shall be made of impervious materials and finished so as to be skid-resistant. Impervious floors are those constructed of a material that resists the absorption of fluids. Such materials include...

  19. 24. Interior view of entrance corridor looking down east corridor; ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    24. Interior view of entrance corridor looking down east corridor; showing unoccupied corner office space and stairs going down to lower floor; center of main section of building on main floor; view to northeast. - Ellsworth Air Force Base, Group Administration & Secure Storage Building, 2372 Westover Avenue, Blackhawk, Meade County, SD

  20. 26 CFR 48.6412-1 - Floor stocks credit or refund.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...; and (D) The quantity of articles held by the dealer as floor stocks on the inventory date. (3) Actual... Revenue Code of 1954 with respect to the articles in my inventory on _____. (Name) By (Signature of... refund authorized by section 6412 for manufacturers excise taxes paid in respect of certain articles held...

  1. 17. Detail view of ceiling and beams on third floor ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    17. Detail view of ceiling and beams on third floor of south section of mill. Note the broom attached to the ceiling, which was used to sweep the leather belts used for power transmission, and the bearing pads bolted to the ceiling as well. - Lowe Mill, Eighth Avenue, Southwest, Huntsville, Madison County, AL

  2. Study Guide for Floorcovering [and Instructor's Key]. V&TECC Curriculum Guide.

    ERIC Educational Resources Information Center

    Duenk, Lester G.; And Others

    Designed for use with industrial cooperative training programs, this study guide on floor covering installation presents the basic foundation knowledge which must be put to practice on the job. The guide begins with a floor covering occupational brief. Specific topics in this section include status of the occupation, working conditions, salary,…

  3. Human Factors Evaluations of Two-Dimensional Spacecraft Conceptual Layouts

    NASA Technical Reports Server (NTRS)

    Kennedy, Kriss J.; Toups, Larry D.; Rudisill, Marianne

    2010-01-01

    Much of the human factors work done in support of the NASA Constellation lunar program has been with low fidelity mockups. These volumetric replicas of the future lunar spacecraft allow researchers to insert test subjects from the engineering and astronaut population and evaluate the vehicle design as the test subjects perform simulations of various operational tasks. However, lunar outpost designs must be evaluated without the use of mockups, creating a need for evaluation tools that can be performed on two-dimension conceptual spacecraft layouts, such as floor plans. A tool based on the Cooper- Harper scale was developed and applied to one lunar scenario, enabling engineers to select between two competing floor plan layouts. Keywords: Constellation, human factors, tools, processes, habitat, outpost, Net Habitable Volume, Cooper-Harper.

  4. Virtual Factory Framework for Supporting Production Planning and Control.

    PubMed

    Kibira, Deogratias; Shao, Guodong

    2017-01-01

    Developing optimal production plans for smart manufacturing systems is challenging because shop floor events change dynamically. A virtual factory incorporating engineering tools, simulation, and optimization generates and communicates performance data to guide wise decision making for different control levels. This paper describes such a platform specifically for production planning. We also discuss verification and validation of the constituent models. A case study of a machine shop is used to demonstrate data generation for production planning in a virtual factory.

  5. 1. Photographic copy of architectural plan for Building 4505, Taylor ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. Photographic copy of architectural plan for Building 4505, Taylor & Barnes, Architects & Engineers, 803 W. Third Street, Los Angeles California, O.C.E. Office of Civil Engineer Job No. A(9-10), Military Construction: Materiel Command Flight Test Base, Muroc, California, Hangar and Auxiliary Buildings: Hangar Type P-A, Floor Plan & Roof Plan, Sheet No. 16, March 1944. Reproduced from the holdings of the National Archives, Pacific Southwest Region - Edwards Air Force Base, North Base, Hangar, End of North Base Road, Boron, Kern County, CA

  6. Web-enabling technologies for the factory floor: a web-enabling strategy for emanufacturing

    NASA Astrophysics Data System (ADS)

    Velez, Ricardo; Lastra, Jose L. M.; Tuokko, Reijo O.

    2001-10-01

    This paper is intended to address the different technologies available for Web-enabling of the factory floor. It will give an overview of the importance of Web-enabling of the factory floor, in the application of the concepts of flexible and intelligent manufacturing, in conjunction with e-commerce. As a last section, it will try to define a Web-enabling strategy for the application in eManufacturing. This is made under the scope of the electronics manufacturing industry, so every application, technology or related matter is presented under such scope.

  7. Gopher Goal.

    ERIC Educational Resources Information Center

    Gilyard, Burl

    2002-01-01

    Describes the design of the University of Minnesota's expansion of its Gibson-Nagurski Football Complex, which included a new entrance (the Hall of Traditions) and weight-training gym. Includes the floor plan and photographs. (EV)

  8. Building Blueprints: Looking Toward the Future.

    ERIC Educational Resources Information Center

    College Planning & Management, 2001

    2001-01-01

    Highlights Kent State University's (Ohio) conversion of its physical education building to a technology building that features fiber optics and advanced cabling systems. Photos and a floor plan are included. (GR)

  9. Art Forms.

    ERIC Educational Resources Information Center

    Hoekstra, Joel

    2002-01-01

    Describes the Fine Arts Interdisciplinary Resource (FAIR) Arts Middle School in Crystal, Minnesota, an award-winning school building that the architects hope will create a more conducive learning environment. Includes photographs and floor plans. (EV)

  10. Photographic copy of construction drawing, dated November 17, 1961, Department ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photographic copy of construction drawing, dated November 17, 1961, Department of the Air Force, Air Defense Command Installations, in possession of Selfridge Base Museum, Mt. Clemens, Michigan. FLOOR PLAN, EQUIPMENT LAYOUT, SITE PLAN, DRAWING NO. P20-130-002 - Selfridge Field, Building No. 1025, Doolittle Drive north of D Street, Mount Clemens, Macomb County, MI

  11. 13. Photocopy of a 1937 plan view drawing of the ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    13. Photocopy of a 1937 plan view drawing of the Basement, First Floor and Balcony of Building No. 701, the Chapel. The HABS film is a high-contrast 8x10' litho negative made from a document in the collection of Vancouver Barracks, Vancouver, WA. - Vancouver Barracks, Chapel, McClelland & McLoughlin Roads, Vancouver, Clark County, WA

  12. 121. ARAI Guard house (ARA628). Drawing shows north, south, east, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    121. ARA-I Guard house (ARA-628). Drawing shows north, south, east, and west elevations, floor plan, counter details, and roof plan. Norman Engineering Corporation 961-area/SF-628-A-1. Date: January 1959. Ineel index code no. 063-0628-00-613-102772. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID

  13. 12. Photographic copy of construction drawing, dated June 7, 1933, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    12. Photographic copy of construction drawing, dated June 7, 1933, Construction Division Office of the Quartermaster General, in possession of Selfridge Base Museum, Mt. Clemens, Michigan. PLAN 625-2517, SDO 186 F41 (FLOOR PLAN) - Selfridge Field, Building Nos. 248, 252 & 254, 248 Birch Street & 252, 254 Wagner Street, Mount Clemens, Macomb County, MI

  14. Simmons Hall, Massachusetts.

    ERIC Educational Resources Information Center

    Amelar, Sarah

    2003-01-01

    Describes the design of Simmons Hall, an undergraduate dormitory at the Massachusetts Institute of Technology, including the educational context and design goals. Includes information on the architects, as well as floor plans and photographs. (EV)

  15. Automatic Generation of Indoor Navigable Space Using a Point Cloud and its Scanner Trajectory

    NASA Astrophysics Data System (ADS)

    Staats, B. R.; Diakité, A. A.; Voûte, R. L.; Zlatanova, S.

    2017-09-01

    Automatic generation of indoor navigable models is mostly based on 2D floor plans. However, in many cases the floor plans are out of date. Buildings are not always built according to their blue prints, interiors might change after a few years because of modified walls and doors, and furniture may be repositioned to the user's preferences. Therefore, new approaches for the quick recording of indoor environments should be investigated. This paper concentrates on laser scanning with a Mobile Laser Scanner (MLS) device. The MLS device stores a point cloud and its trajectory. If the MLS device is operated by a human, the trajectory contains information which can be used to distinguish different surfaces. In this paper a method is presented for the identification of walkable surfaces based on the analysis of the point cloud and the trajectory of the MLS scanner. This method consists of several steps. First, the point cloud is voxelized. Second, the trajectory is analysing and projecting to acquire seed voxels. Third, these seed voxels are generated into floor regions by the use of a region growing process. By identifying dynamic objects, doors and furniture, these floor regions can be modified so that each region represents a specific navigable space inside a building as a free navigable voxel space. By combining the point cloud and its corresponding trajectory, the walkable space can be identified for any type of building even if the interior is scanned during business hours.

  16. 76 FR 45491 - Creation of a Low Power Radio Service; Amendment of Service and Eligibility Rules for FM...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-29

    ... channel floors for the top 150 markets, and proposes to dismiss all translator applications in markets where the number of available LPFM channels is below the channel floor. The item also considers whether... operating on ``third-adjacent'' channels. Section 5 of the LCRA requires the Commission, when licensing FM...

  17. A corridor on the first floor of the building, looking ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    A corridor on the first floor of the building, looking west, shows some of the typical interior finishes in this section. At the end of the hallway, the corridor turns right after entering the next adjacent structure - Department of Energy, Mound Facility, Electronics Laboratory Building (E Building), One Mound Road, Miamisburg, Montgomery County, OH

  18. Impact of vaginal parity and aging on the architectural design of pelvic floor muscles.

    PubMed

    Alperin, Marianna; Cook, Mark; Tuttle, Lori J; Esparza, Mary C; Lieber, Richard L

    2016-09-01

    Vaginal delivery and aging are key risk factors for pelvic floor muscle dysfunction, which is a critical component of pelvic floor disorders. However, alterations in the pelvic floor muscle intrinsic structure that lead to muscle dysfunction because of childbirth and aging remain elusive. The purpose of this study was to determine the impact of vaginal deliveries and aging on human cadaveric pelvic floor muscle architecture, which is the strongest predictor of active muscle function. Coccygeus, iliococcygeus, and pubovisceralis were obtained from younger donors who were ≤51 years old, vaginally nulliparous (n = 5) and vaginally parous (n = 6) and older donors who were >51 years old, vaginally nulliparous (n = 6) and vaginally parous (n = 6), all of whom had no history of pelvic floor disorders. Architectural parameters, which are predictive of muscle's excursion and force-generating capacity, were determined with the use of validated methods. Intramuscular collagen content was quantified by hydroxyproline assay. Main effects of parity and aging and the interactions were determined with the use of 2-way analysis of variance, with Tukey's post-hoc testing and a significance level of .05. The mean age of younger and older donors differed by approximately 40 years (P = .001) but was similar between nulliparous and parous donors within each age group (P > .9). The median parity was 2 (range, 1-3) in younger and older vaginally parous groups (P = .7). The main impact of parity was increased fiber length in the more proximal coccygeus (P = .03) and iliococcygeus (P = .04). Aging changes manifested as decreased physiologic cross-sectional area across all pelvic floor muscles (P < .05), which substantially exceeded the age-related decline in muscle mass. The physiologic cross-sectional area was lower in younger vaginally parous, compared with younger vaginally nulliparous, pelvic floor muscles; however, the differences did not reach statistical significance. Pelvic floor muscle collagen content was not altered by parity but increased dramatically with aging (P < .05). Increased fiber length in more proximal pelvic floor muscles likely represents an adaptive response to the chronically increased load placed on these muscles by the displaced apical structures, presumably as a consequence of vaginal delivery. In younger specimens, a consistent trend towards decrease in force-generating capacity of all pelvic floor muscles in the parous group suggests a potential mechanism for clinically identified pelvic floor muscle weakness in vaginally parous women. The substantial decrease in predicted muscle force production and fibrosis with aging represent likely mechanisms for the pelvic floor muscle dysfunction in older women. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Complete Midline Cleft of Lower Lip, Mandible, Tongue, Floor of Mouth with Neck Contracture: A Case Report and Review of Literature

    PubMed Central

    Rao, Anantheswar Y. N.

    2015-01-01

    Midline cleft of the lower lip and mandible is an extremely rare condition. Since 1819, when the first case was reported by Couronne, fewer than 80 cases have been described in the world literature so far. The cleft has also been described as facial cleft no. 30 by Paul Tessier. The condition varies in severity from a mild variety in which there is a submucous cleft and notching in the lower lip to a severe variety, involving the tongue, floor of the mouth, mandible, absent hyoid, atrophic neck muscles, and sternum. In this case report, a female child having complete midline cleft of the lower lip and mandible, with bifid tongue stuck to the floor of the mouth, absent hyoid bone and flexion contracture band extending from the confluence of the tip of the tongue, floor of the mouth, cleft mandible to the manubrium sterni is described, with special emphasis on surgical planning and management. PMID:26576245

  20. Photocopy of drawing (original in possession of Allegany County, Cumberland, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of drawing (original in possession of Allegany County, Cumberland, MD) CEMENT HOUSE FLOOR PLAN, 1942 - Kelly-Springfield Tire Plant, Cement House, 701 Kelly Road, Cumberland, Allegany County, MD

  1. University of Hull Library

    ERIC Educational Resources Information Center

    Architect Design, 1970

    1970-01-01

    The problems of enlarging the existing library facilities are described. The requirement for complete air-conditioning of the extension caused special design of the external cladding system. Detailed floor plans and photographs are provided. (JW)

  2. Learning Experience.

    ERIC Educational Resources Information Center

    Kapelos, George Thomas

    2001-01-01

    Considers how a controversial new student residence hall at the University of Toronto, Canada, has focused the community's attention on the use of contemporary architecture in dormitory design. Photos and site and floor plans are provided. (GR)

  3. Sales Training Center

    ERIC Educational Resources Information Center

    Training in Business and Industry, 1971

    1971-01-01

    After a year of planning, the American Republic Insurance Company has opened a new training facility which occupies a complete floor of the National Headquarters building in Des Moines. Pictures of the facilities are shown. (EB)

  4. Pelvic floor muscle strength in primiparous women according to the delivery type: cross-sectional study 1

    PubMed Central

    Mendes, Edilaine de Paula Batista; de Oliveira, Sonia Maria Junqueira Vasconcellos; Caroci, Adriana de Souza; Francisco, Adriana Amorim; Oliveira, Sheyla Guimaraes; da Silva, Renata Luana

    2016-01-01

    ABSTRACT Objectives: to compare the pelvic floor muscle strength in primiparous women after normal birth and cesarean section, related to the socio-demographic characteristics, nutritional status, dyspareunia, urinary incontinence, perineal exercise in pregnancy, perineal condition and weight of the newborn. Methods: this was a cross-sectional study conducted after 50 - 70 postpartum days, with 24 primiparous women who underwent cesarean delivery and 72 who had a normal birth. The 9301 PeritronTM was used for analysis of muscle strength. The mean muscle strength was compared between the groups by two-way analysis of variance. Results: the pelvic floor muscle strength was 24.0 cmH2O (±16.2) and 25.4 cmH2O (±14.7) in postpartum primiparous women after normal birth and cesarean section, respectively, with no significant difference. The muscular strength was greater in postpartum women with ≥ 12 years of study (42.0 ±26.3 versus 14.6 ±7.7 cmH2O; p= 0.036) and in those who performed perineal exercises (42.6±25.4 11.8±4.9 vs. cmH2O; p = 0.010), compared to caesarean. There was no difference in muscle strength according to delivery type regarding nutritional status, dyspareunia, urinary incontinence, perineal condition or newborn weight. Conclusion: pelvic floor muscle strength does not differ between primiparous women based on the type of delivery. Postpartum women with normal births, with higher education who performed perineal exercise during pregnancy showed greater muscle strength. PMID:27533267

  5. 20. Photocopy of ink and wash drawing by Richard Upjohn, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    20. Photocopy of ink and wash drawing by Richard Upjohn, circa 1839, in Avery Library, Columbia University FIRST AND SECOND FLOOR PLANS - Kingscote, Bellevue Avenue & Bowery Street, Newport, Newport County, RI

  6. 6. Photocopy of original drawing by Barney & Chapman, Architects, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. Photocopy of original drawing by Barney & Chapman, Architects, 1901 PLAN OF FIRST FLOOR, DORMITORY BUILDING - Thomas Asylum for Orphan & Destitute Indians, Dormitory, Route 438, Cattaraugas Reservation, Irving, Chautauqua County, NY

  7. Studies in Interior Design

    ERIC Educational Resources Information Center

    Environ Planning Design, 1970

    1970-01-01

    Floor plans and photographs illustrate a description of the Samuel C. Williams Library at Stevens Institute of Technology, Hoboken, N.J. The unusual interior design allows students to take full advantage of the library's resources. (JW)

  8. Manufacture of industrial products from oak

    Treesearch

    Hugh W. Reynolds

    1971-01-01

    The three largest and fastest growing markets for oak are railroad crossties, reusable pallets, and truck and container flooring. Manufacturers of oak lumber are advised to keep these products in mind when planning their production.

  9. Northeastern Exterior, Northwestern Exterior, & Southwestern Exterior Elevations, Northeastern Interior, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Northeastern Exterior, Northwestern Exterior, & Southwestern Exterior Elevations, Northeastern Interior, Southeastern Interior, & Southwestern Interior Elevations, Floor Plan, and Eastern Corner Detail - Manatoc Reservation, Vale Edge Adirondack, 1075 Truxell Road, Peninsula, Summit County, OH

  10. Shopping Mall to Study Hall.

    ERIC Educational Resources Information Center

    Rittner-Heir, Robbin M.

    1999-01-01

    Discusses how the Burnsville (Minnesota) expanded its high school classroom space by buying a shopping mall and converting it into classrooms. Renovation costs and classroom layout are briefly discussed; a floor plan is included. (GR)

  11. Structural and Functional Concepts in Current Mouse Phenotyping and Archiving Facilities

    PubMed Central

    Kollmus, Heike; Post, Rainer; Brielmeier, Markus; Fernández, Julia; Fuchs, Helmut; McKerlie, Colin; Montoliu, Lluis; Otaegui, Pedro J; Rebelo, Manuel; Riedesel, Hermann; Ruberte, Jesús; Sedlacek, Radislav; de Angelis, Martin Hrabě; Schughart, Klaus

    2012-01-01

    Collecting and analyzing available information on the building plans, concepts, and workflow from existing animal facilities is an essential prerequisite for most centers that are planning and designing the construction of a new animal experimental research unit. Here, we have collected and analyzed such information in the context of the European project Infrafrontier, which aims to develop a common European infrastructure for high-throughput systemic phenotyping, archiving, and dissemination of mouse models. A team of experts visited 9 research facilities and 3 commercial breeders in Europe, Canada, the United States, and Singapore. During the visits, detailed data of each facility were collected and subsequently represented in standardized floor plans and descriptive tables. These data showed that because the local needs of scientists and their projects, property issues, and national and regional laws require very specific solutions, a common strategy for the construction of such facilities does not exist. However, several basic concepts were apparent that can be described by standardized floor plans showing the principle functional units and their interconnection. Here, we provide detailed information of how individual facilities addressed their specific needs by using different concepts of connecting the principle units. Our analysis likely will be valuable to research centers that are planning to design new mouse phenotyping and archiving facilities. PMID:23043807

  12. Management of disorders of the posterior pelvic floor.

    PubMed Central

    Berman, Loren; Aversa, John; Abir, Farshad; Longo, Walter E.

    2005-01-01

    INTRODUCTION: Constipation is a relatively common problem affecting 15 percent of adults in the Western world, and over half of these cases are related to pelvic floor disorders. This article reviews the clinical presentation and diagnostic approach to posterior pelvic floor disorders, including how to image and treat them. METHODS: A Pubmed search using keywords "rectal prolapse," "rectocele," "perineal hernia," and "anismus" was performed, and bibliographies of the revealed articles were cross-referenced to obtain a representative cross-section of the literature, both investigational studies and reviews, that are currently available on posterior pelvic floor disorders. DISCUSSION: Pelvic floor disorders can occur with or without concomitant physical anatomical defects, and there are a number of imaging modalities available to detect such abnormalities in order to decide on the appropriate course of treatment. Depending on the nature of the disorder, operative or non-operative therapy may be indicated. CONCLUSION: Correctly diagnosing pelvic floor disorders can be complex and challenging, and the various imaging modalities as well as clinical history and exam must be considered together in order to arrive at a diagnosis. PMID:16720016

  13. Finite Element Models and Properties of a Stiffened Floor-Equipped Composite Cylinder

    NASA Technical Reports Server (NTRS)

    Grosveld, Ferdinand W.; Schiller, Noah H.; Cabell, Randolph H.

    2010-01-01

    Finite element models were developed of a floor-equipped, frame and stringer stiffened composite cylinder including a coarse finite element model of the structural components, a coarse finite element model of the acoustic cavities above and below the beam-supported plywood floor, and two dense models consisting of only the structural components. The report summarizes the geometry, the element properties, the material and mechanical properties, the beam cross-section characteristics, the beam element representations and the boundary conditions of the composite cylinder models. The expressions used to calculate the group speeds for the cylinder components are presented.

  14. Effects of prescribed fire in giant sequoia-mixed conifer stands in Sequoia and Kings Canyon National Parks

    Treesearch

    Sally M. Haase; Stephen S. Sackett

    1998-01-01

    Many national parks have incorporated the use of management-ignited prescribed fire in their management plans. Soil and cambium heating, forest floor fuel reduction, and soil nutrient increases have been measured on eight independent, planned management fires over a 9-year period in Sequoia and Kings Canyon National Parks. Findings show that instantaneous lethal...

  15. 40 CFR Table 7 to Subpart IIIii of... - Required Elements of Washdown Plans

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... baskets 6. Hydrogen system piping 7. Basement floor of cell rooms 8. Tanks 9. Pillars and beams in cell... Mercury Cell Chlor-Alkali Plants Pt. 63, Subpt. IIIII, Table 7 Table 7 to Subpart IIIII of Part 63... following as part of your plan . . . 1. Center aisles of cell rooms A description of the manner of washdown...

  16. 40 CFR Table 7 to Subpart IIIii of... - Required Elements of Washdown Plans

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... baskets 6. Hydrogen system piping 7. Basement floor of cell rooms 8. Tanks 9. Pillars and beams in cell... Mercury Cell Chlor-Alkali Plants Pt. 63, Subpt. IIIII, Table 7 Table 7 to Subpart IIIII of Part 63... following as part of your plan . . . 1. Center aisles of cell rooms A description of the manner of washdown...

  17. ADM. Water well pump houses (TAN612 and TAN613). Plans, elevations, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    ADM. Water well pump houses (TAN-612 and TAN-613). Plans, elevations, floor and other details. Ralph M. Parsons 902-2-ANP-612-613-A S & P 82. Date: December 1952. Approved by INEEL Classification Office for public release. INEEL index code no. 035-0612-00-693-106743 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  18. 40 CFR Table 7 to Subpart IIIii of... - Required Elements of Washdown Plans

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Mercury Cell Chlor-Alkali Plants Pt. 63, Subpt. IIIII, Table 7 Table 7 to Subpart IIIII of Part 63... following as part of your plan . . . 1. Center aisles of cell rooms A description of the manner of washdown... baskets 6. Hydrogen system piping 7. Basement floor of cell rooms 8. Tanks 9. Pillars and beams in cell...

  19. Ventilation Surge Techniques. Volume I

    DTIC Science & Technology

    1981-12-01

    studying wind-driven ventilation. S-I - . .--. .-.. .F 77I I11. EXPERIMENTAL DESIGN The full-scale model used in the experimental portion of the study was... designed to represent a typical host-area shelter. It had plan dimensions of 32 feet by 48 feet. Three floor plans were used within the same exterior...11-12 III. EXPERIMENTAL DESIGN . . . . . . . . . . . . . . . . . . . III-1 A. Literature Review . . . . . . . . . . . . . . . . . III

  20. 40 CFR Table 7 to Subpart IIIii of... - Required Elements of Washdown Plans

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Mercury Cell Chlor-Alkali Plants Pt. 63, Subpt. IIIII, Table 7 Table 7 to Subpart IIIII of Part 63... following as part of your plan . . . 1. Center aisles of cell rooms A description of the manner of washdown... baskets 6. Hydrogen system piping 7. Basement floor of cell rooms 8. Tanks 9. Pillars and beams in cell...

  1. 40 CFR Table 7 to Subpart IIIii of... - Required Elements of Washdown Plans

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Mercury Cell Chlor-Alkali Plants Pt. 63, Subpt. IIIII, Table 7 Table 7 to Subpart IIIII of Part 63... following as part of your plan . . . 1. Center aisles of cell rooms A description of the manner of washdown... baskets 6. Hydrogen system piping 7. Basement floor of cell rooms 8. Tanks 9. Pillars and beams in cell...

  2. 76 FR 35066 - Self-Regulatory Organizations; Chicago Board Options Exchange, Incorporated; Notice of Filing and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-15

    ... an Exchange-sponsored terminal (e.g. a Floor Broker Workstation).\\3\\ However, the institution of this... Floor Broker Workstation) will still be exempt from such fees. This change is consistent with the... the objectives of Section 6(b)(4) \\5\\ of the Act in particular, in that it is designed to provide for...

  3. 78 FR 62825 - Self-Regulatory Organizations; New York Stock Exchange LLC; Notice of Filing and Immediate...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-22

    ... Permit Floor Brokers To Use Personal Portable Phone Devices on The Trading Floor Due to the Unavailability of Exchange- Provided Cell Phones Beginning on October 10, 2013 Until the Earlier of When Cell Phone Service Is Restored or October 11, 2013 October 16, 2013. Pursuant to Section 19(b)(1) \\1\\ of the...

  4. 78 FR 62802 - Self-Regulatory Organizations; NYSE MKT LLC; Notice of Filing and Immediate Effectiveness of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-22

    ... Not Permit Floor Brokers To Use Personal Portable Phone Devices on the Trading Floor Due to the Unavailability of Exchange-Provided Cell Phones Beginning on October 10, 2013 Until the Earlier of When Cell Phone Service Is Restored or October 11, 2013 October 16, 2013. Pursuant to Section 19(b)(1) \\1\\ of the...

  5. Abundance and distribution of vegetation under four hardwood stands in north-central West Virginia

    Treesearch

    G.W. Wendel; G.W. Wendel

    1987-01-01

    Forest floor samples were collected from four hardwood forest stands in West Virginia to study species composition, abundance, and distribution of vegetation that originated from seeds, rootstocks, rhizomes, and so on. The abundance and distribution of plants on square-foot sections of forest floor that were lifted and moved to the greenhouse indicate that under the...

  6. 7 CFR 29.75a - Display of burley tobacco on auction warehouse floors in designated markets.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... in designated markets. 29.75a Section 29.75a Agriculture Regulations of the Department of Agriculture... § 29.75a Display of burley tobacco on auction warehouse floors in designated markets. (a)(1) Each lot... arrayed sequence of lots and rows of tobacco, shall have prior approval of the Set Work Leader or Circuit...

  7. Pelvic Floor Disorders After Childbirth: Effect of Episiotomy, Perineal Laceration, and Operative Birth

    PubMed Central

    Handa, Victoria L.; Blomquist, Joan L.; McDermott, Kelly C.; Friedman, Sarah; Muñoz, Alvaro

    2011-01-01

    Objective To investigate whether episiotomy, perineal laceration, and operative delivery are associated with pelvic floor disorders after vaginal childbirth. Methods This is a planned analysis of data for a cohort study of pelvic floor disorders. Participants who had experienced at least one vaginal birth were recruited 5–10 years after delivery of their first child. Obstetric exposures were classified by review of hospital records. At enrollment, pelvic floor outcomes, including stress incontinence, overactive bladder, anal incontinence, and prolapse symptoms were assessed with a validated questionnaire. Pelvic organ support was assessed using the Pelvic Organ Prolapse Quantification system. Logistic regression analysis was used to estimate the relative odds of each pelvic floor disorder by obstetric history, adjusting for relevant confounders. Results Of 449 participants, 71 (16%) had stress incontinence, 45 (10%) had overactive bladder, 56 (12%) had anal incontinence, 19 (4%) had prolapse symptoms and 64 (14%) had prolapse to or beyond the hymen on examination. Forceps delivery increased the odds of each pelvic floor disorder considered, especially overactive bladder (odds ratio 2.92, 95% confidence interval 1.44, 5.93) and prolapse (odds ratio 1.95, 95% confidence interval 1.03, 3.70). Episiotomy was not associated with any of these pelvic floor disorders. In contrast, women with a history of more than one spontaneous perineal laceration were significantly more likely to have prolapse to or beyond the hymen (odds ratio 2.34, 95% confidence interval 1.13, 4.86). Our multivariable results suggest that one additional woman would develop prolapse for every 8 women who experienced at least one forceps birth (versus delivering all her children by spontaneous vaginal birth). Conclusion Forceps deliveries and perineal lacerations, but not episiotomies, were associated with pelvic floor disorders 5–10 years after a first delivery. PMID:22227639

  8. Model-based tomographic reconstruction

    DOEpatents

    Chambers, David H; Lehman, Sean K; Goodman, Dennis M

    2012-06-26

    A model-based approach to estimating wall positions for a building is developed and tested using simulated data. It borrows two techniques from geophysical inversion problems, layer stripping and stacking, and combines them with a model-based estimation algorithm that minimizes the mean-square error between the predicted signal and the data. The technique is designed to process multiple looks from an ultra wideband radar array. The processed signal is time-gated and each section processed to detect the presence of a wall and estimate its position, thickness, and material parameters. The floor plan of a building is determined by moving the array around the outside of the building. In this paper we describe how the stacking and layer stripping algorithms are combined and show the results from a simple numerical example of three parallel walls.

  9. 44. Photocopy of drawing (Source unknown, 1928) Rapid Blue Print ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    44. Photocopy of drawing (Source unknown, 1928) Rapid Blue Print Co., Los Angeles, CA, Photographer, Date unknown FIRST FLOOR PLAN - Richfield Oil Building, 555 South Flower Street, Los Angeles, Los Angeles County, CA

  10. 45. Photocopy of drawing (Source unknown, 1928) Rapid Blue Print ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    45. Photocopy of drawing (Source unknown, 1928) Rapid Blue Print Co., Los Angeles, CA, Photographer, Date unknown SECOND FLOOR PLAN - Richfield Oil Building, 555 South Flower Street, Los Angeles, Los Angeles County, CA

  11. 10. Historic American Buildings Survey CFA Staff, Photographer, 1972 FIRST ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey CFA Staff, Photographer, 1972 FIRST- SECOND- FLOOR PLAN J. L. S. Jennings, Jr., Delineator - Edward H. Everett House, 1606 Twenty-third Street Northwest, Washington, District of Columbia, DC

  12. 2. Historic American Buildings Survey Photocopy: Albern Color Research, Inc. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. Historic American Buildings Survey Photocopy: Albern Color Research, Inc. August, 1960 FIRST AND SECOND FLOOR PLANS DATED OCTOBER 28, 1914 - Dartmouth College, Webster Cottage, 27B Main Street, Hanover, Grafton County, NH

  13. 14. NORTHWEST PARLOR, SHOWING BAY WINDOW AND DRYWALLED ENTRY TO ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    14. NORTHWEST PARLOR, SHOWING BAY WINDOW AND DRYWALLED ENTRY TO ADJACENT PARLOR. ROOM 2, HIRSHEN TRUMBO SECOND FLOOR PLAN. VIEW TO NORTH. - Davis-Byrne Building, 2134-2140 Dwight Way, Berkeley, Alameda County, CA

  14. 12. Photographic copy of architect's rendering, from the pencil tracings ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    12. Photographic copy of architect's rendering, from the pencil tracings in the possession of Potter, Lawson and Pawlowsky, TYPICAL FLOOR PLAN - Manchester's Department Store Building, 2 East Mifflin Street, Madison, Dane County, WI

  15. Molds in floor dust and building-related symptoms among adolescent school children: a problem for boys only?

    PubMed

    Meyer, H W; Würtz, H; Suadicani, P; Valbjørn, O; Sigsgaard, T; Gyntelberg, F

    2005-01-01

    In this stratified cross-sectional study in eight 'wet' and seven 'dry' schools, 1024 adolescent school children reported potentially building-related symptoms (BRS) in self-administrated questionnaires. From their classrooms dust samples were collected from floors, ventilation ducts, and air; settled dust was collected in cardboard boxes over a period of 5 months. Measurements of temperature, relative humidity and CO2 were performed. BRS were strongly associated with personal factors like recent airway infections, hay fever, asthma and psycho-social work load, but also to molds in floor dust and presence of mechanical ventilation. The association between molds in floor dust and BRS has in stratified analyses shown a strong association among adolescent school boys, and no association among adolescent school girls using multivariable analyses controlling for relevant confounders. In contrast to the menstruating school girls, the symptoms among the small group of not yet menstruating girls were associated with the levels of molds in floor dust. Their symptom prevalences were very similar to those of the boys. This finding makes us suggest a new hypothesis: The higher endogenous estrogen levels of sexually matured adolescent females seems to protect them from the effects of molds in dust, despite their overall higher symptom prevalence. In this cross-sectional epidemiological study of adolescent school children we found independent significant positive associations between building-related symptoms and viable molds in floor dust in boys and non-menstruating girls. In contrast, no such associations were seen among menstruating girls. The identification of these two susceptible groups adds further support the relevance of minimizing sources of dust and mold exposure.

  16. Ultrasound imaging of the pelvic floor: changes in anatomy during and after first pregnancy.

    PubMed

    van Veelen, G A; Schweitzer, K J; van der Vaart, C H

    2014-10-01

    To describe changes in the absolute values of levator hiatal dimensions and in the contractility and distensibility of the levator hiatus during pelvic floor contraction and Valsalva maneuver, using three/four-dimensional (3D/4D) transperineal ultrasound in women during and after their first pregnancy. Two-hundred and eighty nulliparous pregnant women underwent ultrasound examination at 12 and 36 weeks' gestation and 6 months postpartum. Hiatal dimensions were measured at rest, on pelvic floor contraction and on Valsalva maneuver. The contractility and distensibility were determined by the difference between hiatal dimensions at rest and those on contraction or Valsalva, respectively. After exclusions, there were 231 datasets from women at rest, 199 for pelvic floor contraction and 230 for Valsalva maneuver. Data at 36 weeks' gestation and 6 months postpartum were compared with data at 12 weeks' gestation. At 36 weeks' gestation, the absolute values of hiatal dimensions and the contractility and distensibility of the levator hiatus were significantly increased compared with those at 12 weeks' gestation. Women who delivered vaginally showed a persistent significant increase in hiatal dimensions on Valsalva, whereas women who delivered by prelabor or first-stage Cesarean section showed no significant changes in hiatal dimensions on Valsalva. After both vaginal and Cesarean section delivery, there was a persistent increase in the distensibility of the hiatus during Valsalva compared with in early pregnancy. During first pregnancy, the absolute values of levator hiatal dimensions and the contractility and distensibility of the levator hiatus increase. Regardless of delivery mode, increased distensibility of the levator hiatus during Valsalva persists after childbirth. This increased pelvic floor distensibility may play a role in the development of pelvic floor dysfunction in later life. Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.

  17. Investigation of Seal-to-Floor Effects on Semi-Span Transonic Models

    NASA Technical Reports Server (NTRS)

    Sleppy, Mark A.; Engel, Eric A.; Watson, Kevin T.; Atler, Douglas M.

    2009-01-01

    In an effort to achieve the maximum possible Reynolds number (Re) when conducting production testing for flight loads aerodynamic databases, it has been the preferred practice of The Boeing Company / Commercial Airplanes (BCA) -- Loads and Dynamics Group since the early 1990's to test large scale semi-span models in the 11- By 11-Foot Transonic Wind Tunnel (TWT) leg of the Unitary Plan Wind Tunnel (UPWT) at the NASA Ames Research Center (ARC). There are many problems related to testing large scale semi-span models of high aspect ratio flexible transport wings, such as; floor boundary layer effects, wing spanwise wall effects, solid blockage buoyancy effects, floor mechanical interference effects, airflow under the model effects, or tunnel flow gradient effects. For most of these issues, BCA has developed and implemented either standard testing methods or numerical correction schemes and these will not be discussed in this document. Other researchers have reported on semi-span transonic testing correction issues, however most of the reported research has been for low Mach testing. Some of the reports for low Mach testing address the difficult problem of preventing undesirable airflow under a semi-span model while ensuring unrestricted main balance functionality, however, for transonic models this issue has gone unresolved. BCA has been cognizant for sometime that there are marked differences in wing pressure distributions from semi-span transonic model testing than from full model or flight testing. It has been suspected that these differences are at least in part due to airflow under the model. Previous efforts by BCA to address this issue have proven to be ineffective or inconclusive and in one situation resulted in broken hardware. This paper reports on a Boeing-NASA collaborative investigation based on a series of small tests conducted between June 2006 and November 2007 in the 11 by 11 foot Transonic Wind Tunnel at NASA Ames on three large commercial jet transport configurations to assess the effects of sealing a semi-span model to the floor and to investigate efficient sealing and testing techniques. This document will show how sealing the model to the floor has a small but remarkably far reaching spanwise effect on wing pressures, wing local section forces and wing force summations.

  18. Advantages and limitations of remotely operated sea floor drill rigs

    NASA Astrophysics Data System (ADS)

    Freudenthal, T.; Smith, D. J.; Wefer, G.

    2009-04-01

    A variety of research targets in marine sciences including the investigation of gas hydrates, slope stability, alteration of oceanic crust, ore formation and palaeoclimate can be addressed by shallow drilling. However, drill ships are mostly used for deep drillings, both because the effort of building up a drill string from a drill ship to the deep sea floor is tremendous and control on drill bit pressure from a movable platform and a vibrating drill string is poor especially in the upper hundred meters. During the last decade a variety of remotely operated drill rigs have been developed, that are deployed on the sea bed and operated from standard research vessels. These developments include the BMS (Bentic Multicoring System, developed by Williamson and Associates, operated by the Japanese Mining Agency), the PROD (Portable Remotely Operated Drill, developed and operated by Benthic Geotech), the Rockdrill 2 (developed and operated by the British geological Survey) and the MeBo (German abbreviation for sea floor drill rig, developed and operated by Marum, University of Bremen). These drill rigs reach drilling depths between 15 and 100 m. For shallow drillings remotely operated drill rigs are a cost effective alternative to the services of drill ships and have the major advantage that the drilling operations are performed from a stable platform independent of any ship movements due to waves, wind or currents. Sea floor drill rigs can be deployed both in shallow waters and the deep sea. A careful site survey is required before deploying the sea floor drill rig. Slope gradient, small scale topography and soil strength are important factors when planning the deployment. The choice of drill bits and core catcher depend on the expected geology. The required drill tools are stored on one or two magazines on the drill rig. The MeBo is the only remotely operated drill rig world wide that can use wire line coring technique. This method is much faster than conventional drilling. It has the advantage that the drill string stays in the drilled hole during the entire drilling process and prevents the drilled hole from collapsing while the inner core barrels comprising the drilled core sections are hooked up inside the drill string using a wire.

  19. The prevalence of pelvic floor disorders and their relationship to gender, age, parity and mode of delivery.

    PubMed

    MacLennan, A H; Taylor, A W; Wilson, D H; Wilson, D

    2000-12-01

    To define the prevalence of pelvic floor disorders in a non-institutionalised community and to determine the relationship to gender, age, parity and mode of delivery. A representative population survey using the 1998 South Australian Health Omnibus Survey. Random selection of 4400 households; 3010 interviews were conducted in the respondents' homes by trained female interviewers. This cross sectional survey included men and women aged 15-97 years. The prevalence of all types of self-reported urinary incontinence in men was 4.4% and in women was 35.3% (P<0.001). Urinary incontinence was more commonly reported in nulliparous women than men and increased after pregnancy according to parity and age. The highest prevalence (51.9%) was reported in women aged 70-74 years. The prevalence of flatus and faecal incontinence was 6.8% and 2.3% in men and 10.9% and 3.5% in women, respectively. Pregnancy (> 20 weeks), regardless of the mode of delivery, greatly increased the prevalence of major pelvic floor dysfunction, defined as any type of incontinence, symptoms of prolapse or previous pelvic floor surgery. Multivariate logistic regression showed that, compared with nulliparity, pelvic floor dysfunction was significantly associated with caesarean section (OR 2.5, 95% CI 1.5-4.3), spontaneous vaginal delivery (OR 3.4, 95% CI 2.4-4.9) and at least one instrumental delivery (OR 4.3, 95% CI 2.8-6.6). The difference between caesarean and instrumental delivery was significant (P<0.03) but was not for caesarean and spontaneous delivery. Other associations with pelvic floor morbidity were age, body mass index, coughing, osteoporosis, arthritis and reduced quality of life scores. Symptoms of haemorrhoids also increased with age and parity and were reported in 19.9% of men and 30.2% of women. Pelvic floor disorders are very common and are strongly associated with female gender, ageing, pregnancy, parity and instrumental delivery. Caesarean delivery is not associated with a significant reduction in long term pelvic floor morbidity compared with spontaneous vaginal delivery.

  20. Modelling the pelvic floor for investigating difficulties during childbirth

    NASA Astrophysics Data System (ADS)

    Li, Xinshan; Kruger, Jennifer A.; Chung, Jae-Hoon; Nash, Martyn P.; Nielsen, Poul M. F.

    2008-03-01

    Research has suggested that athletes involved in high-intensity sports for sustained periods have a higher probability of experiencing prolonged second stage of labour compared to non-athletes. The mechanism responsible for this complication is unknown but may depend on the relative size or tone of the pelvic floor muscles. Prolonged training can result in enlargement and stiffening of these muscles, providing increased resistance as the fetal head descends through the birth canal during a vaginal birth. On the other hand, recent studies have suggested an association between increased muscle bulk in athletes and higher distensibility. This project aims to use mathematical modelling to study the relationship between the size and tone of the pelvic floor muscles and the level of difficulty during childbirth. We obtained sets of magnetic resonance (MR) images of the pelvic floor region for a female athlete and a female non-athlete. Thirteen components of the pelvic floor were segmented and used to generate finite element (FE) models. The fetal head data was obtained by laser scanning a skull replica and a FE model was fitted to these data. We used contact mechanics to simulate the motion of the fetal head moving through the pelvic floor, constructed from the non-athlete data. A maximum stretch ratio of 3.2 was induced in the muscle at the left lateral attachment point to the pubis. We plan to further improve our modelling framework to include active muscle contraction and fetal head rotations in order to address the hypotheses that there is a correlation between the level of difficulty and the size or tone of the pelvic floor muscles.

Top