Integration of a molten carbonate fuel cell with a direct exhaust absorption chiller
NASA Astrophysics Data System (ADS)
Margalef, Pere; Samuelsen, Scott
A high market value exists for an integrated high-temperature fuel cell-absorption chiller product throughout the world. While high-temperature, molten carbonate fuel cells are being commercially deployed with combined heat and power (CHP) and absorption chillers are being commercially deployed with heat engines, the energy efficiency and environmental attributes of an integrated high-temperature fuel cell-absorption chiller product are singularly attractive for the emerging distributed generation (DG) combined cooling, heating, and power (CCHP) market. This study addresses the potential of cooling production by recovering and porting the thermal energy from the exhaust gas of a high-temperature fuel cell (HTFC) to a thermally activated absorption chiller. To assess the practical opportunity of serving an early DG-CCHP market, a commercially available direct fired double-effect absorption chiller is selected that closely matches the exhaust flow and temperature of a commercially available HTFC. Both components are individually modeled, and the models are then coupled to evaluate the potential of a DG-CCHP system. Simulation results show that a commercial molten carbonate fuel cell generating 300 kW of electricity can be effectively coupled with a commercial 40 refrigeration ton (RT) absorption chiller. While the match between the two "off the shelf" units is close and the simulation results are encouraging, the match is not ideal. In particular, the fuel cell exhaust gas temperature is higher than the inlet temperature specified for the chiller and the exhaust flow rate is not sufficient to achieve the potential heat recovery within the chiller heat exchanger. To address these challenges, the study evaluates two strategies: (1) blending the fuel cell exhaust gas with ambient air, and (2) mixing the fuel cell exhaust gases with a fraction of the chiller exhaust gas. Both cases are shown to be viable and result in a temperature drop and flow rate increase of the gases before the chiller inlet. The results show that no risk of cold end corrosion within the chiller heat exchanger exists. In addition, crystallization is not an issue during system operation. Accounting for the electricity and the cooling produced and disregarding the remaining thermal energy, the second strategy is preferred and yields an overall estimated efficiency of 71.7%.
Commercial absorption chiller models for evaluation of control strategies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koeppel, E.A.; Klein, S.A.; Mitchell, J.W.
1995-08-01
A steady-state computer simulation model of a direct fired double-effect water-lithium bromide absorption chiller in the parallel-flow configuration was developed from first principles. Unknown model parameters such as heat transfer coefficients were determined by matching the model`s calculated state points and coefficient of performance (COP) against nominal full-load operating data and COPs obtained from a manufacturer`s catalog. The model compares favorably with the manufacturer`s performance ratings for varying water circuit (chilled and cooling) temperatures at full load conditions and for chiller part-load performance. The model was used (1) to investigate the effect of varying the water circuit flow rates withmore » the chiller load and (2) to optimize chiller part-load performance with respect to the distribution and flow of the weak solution.« less
Improvement of the COP of the LiBr-Water Double-Effect Absorption Cycles
NASA Astrophysics Data System (ADS)
Shitara, Atsushi
Prevention of the global warming has called for a great necessity for energy saving. This applies to the improvement of the COP of absorption chiller-heaters. We started the development of the high efficiency gas-fired double-effect absorption chiller-heater using LiBr-H2O to achieve target performance in short or middle term. To maintain marketability, the volume of the high efficiency machine has been set below the equal to the conventional machine. The absorption cycle technology for improving the COP and the element technology for downsizing the machine is necessary in this development. In this study, the former is investigated. In this report, first of all the target performance has been set at cooling COP of 1.35(on HHV), which is 0.35 higher than the COP of 1.0 for conventional machines in the market. This COP of 1.35 is practically close to the maximum limit achievable by double-effect absorption chiller-heater. Next, the design condition of each element to achieve the target performance and the effect of each mean to improve the COP are investigated. Moreover, as a result of comparing the various flows(series, parallel, reverse)to which the each mean is applied, it has been found the optimum cycle is the parallel flow.
Heat and Mass Transfer in a Falling Film Evaporator with Aqueous Lithium Bromide Solution
NASA Astrophysics Data System (ADS)
Olbricht, M.; Addy, J.; Luke, A.
2016-09-01
Horizontal tube bundles are often used as falling film evaporators in absorption chillers, especially for systems working at low pressure as H2O/LiBr. Experimental investigations are carried out in a falling film evaporator consisting of a horizontal tube bundle with eighty horizontal tubes installed in an absorption chiller because of a lack of consistent data for heat and mass transfer in the literature. The heat and mass transfer mechanisms and the flow pattern in the falling film are analysed and compared with correlations from literature. The deviations of the experimental data from those of the correlations are within a tolerance of 30%. These deviations may be explained by a change of the flow pattern at a lower Reynolds number than compared to the literature.
Site dependent factors affecting the economic feasibility of solar powered absorption cooling
NASA Technical Reports Server (NTRS)
Bartlett, J. C.
1978-01-01
A procedure was developed to evaluate the cost effectiveness of combining an absorption cycle chiller with a solar energy system. A basic assumption of the procedure is that a solar energy system exists for meeting the heating load of the building, and that the building must be cooled. The decision to be made is to either cool the building with a conventional vapor compression cycle chiller or to use the existing solar energy system to provide a heat input to the absorption chiller. Two methods of meeting the cooling load not supplied by solar energy were considered. In the first method, heat is supplied to the absorption chiller by a boiler using fossil fuel. In the second method, the load not met by solar energy is net by a conventional vapor compression chiller. In addition, the procedure can consider waste heat as another form of auxiliary energy. Commercial applications of solar cooling with an absorption chiller were found to be more cost effective than the residential applications. In general, it was found that the larger the chiller, the more economically feasible it would be. Also, it was found that a conventional vapor compression chiller is a viable alternative for the auxiliary cooling source, especially for the larger chillers. The results of the analysis gives a relative rating of the sites considered as to their economic feasibility of solar cooling.
The economics of solar powered absorption cooling
NASA Technical Reports Server (NTRS)
Bartlett, J. C.
1978-01-01
Analytic procedure evaluates cost of combining absorption-cycle chiller with solar-energy system in residential or commercial application. Procedure assumes that solar-energy system already exists to heat building and that cooling system must be added. Decision is whether to cool building with conventional vapor-compression-cycle chiller or to use solar-energy system to provide heat input to absorption chiller.
Low-cost thin-film absorber/evaporator for an absorption chiller. Final report, May 1992-April 1993
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lowenstein, A.; Sibilia, M.
1993-04-01
The feasibility of making the absorber and evaporator of a small lithium-bromide absorption chiller from thin plastic films was studied. Tests were performed to measure (1) pressure limitations for a plastic thin-film heat exchanger, (2) flow pressure-drop characteristics, (3) air permeation rates across the plastic films, and (4) creep characteristics of the plastic films. Initial tests were performed on heat exchangers made of either low-density polyethylene (LDPE), high-density polyethylene (HDPE), or a LDPE/HDPE blend. While initial designs for the heat exchanger failed at internal pressures of only 5 to 6 psi, the final design could withstand pressures of 34 psi.
Corrosion Problems in Absorption Chillers
ERIC Educational Resources Information Center
Stetson, Bruce
1978-01-01
Absorption chillers use a lithium bromide solution as the medium of absorption and water as the refrigerant. Discussed are corrosion and related problems, tests and remedies, and cleaning procedures. (Author/MLF)
LiCl Dehumidifier LiBr absorption chiller hybrid air conditioning system with energy recovery
Ko, Suk M.
1980-01-01
This invention relates to a hybrid air conditioning system that combines a solar powered LiCl dehumidifier with a LiBr absorption chiller. The desiccant dehumidifier removes the latent load by absorbing moisture from the air, and the sensible load is removed by the absorption chiller. The desiccant dehumidifier is coupled to a regenerator and the desiccant in the regenerator is heated by solar heated hot water to drive the moisture therefrom before being fed back to the dehumidifier. The heat of vaporization expended in the desiccant regenerator is recovered and used to partially preheat the driving fluid of the absorption chiller, thus substantially improving the overall COP of the hybrid system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurnik, Charles W; Tiessen, Alex
This protocol defines a chiller measure as a project that directly impacts equipment within the boundary of a chiller plant. A chiller plant encompasses a chiller - or multiple chillers - and associated auxiliary equipment. This protocol primarily covers electric-driven chillers and chiller plants. It does not include thermal energy storage and absorption chillers fired by natural gas or steam, although a similar methodology may be applicable to these chilled water system components.
Solid oxide fuel cell/gas turbine trigeneration system for marine applications
NASA Astrophysics Data System (ADS)
Tse, Lawrence Kar Chung; Wilkins, Steven; McGlashan, Niall; Urban, Bernhard; Martinez-Botas, Ricardo
2011-03-01
Shipping contributes 4.5% to global CO2 emissions and is not covered by the Kyoto Agreement. One method of reducing CO2 emissions on land is combined cooling heating and power (CCHP) or trigeneration, with typical combined thermal efficiencies of over 80%. Large luxury yachts are seen as an ideal entry point to the off-shore market for this developing technology considering its current high cost. This paper investigates the feasibility of combining a SOFC-GT system and an absorption heat pump (AHP) in a trigeneration system to drive the heating ventilation and air conditioning (HVAC) and electrical base-load systems. A thermodynamic model is used to simulate the system, with various configurations and cooling loads. Measurement of actual yacht performance data forms the basis of this system simulation. It is found that for the optimum configuration using a double effect absorption chiller in Ship 1, the net electric power increases by 47% relative to the electrical power available for a conventional SOFC-GT-HVAC system. This is due to more air cooled to a lower temperature by absorption cooling; hence less electrical cooling by the conventional HVAC unit is required. The overall efficiency is 12.1% for the conventional system, 34.9% for the system with BROAD single effect absorption chiller, 43.2% for the system with double effect absorption chiller. This shows that the overall efficiency of a trigeneration system is far higher when waste heat recovery happens. The desiccant wheel hardly reduces moisture from the outdoor air due to a relative low mass flow rate of fuel cell exhaust available to dehumidify a very large mass flow rate of HVAC air, Hence, desiccant wheel is not recommended for this application.
A Lithium Bromide Absorption Chiller with Cold Storage
2011-01-15
Research ABSTRACT A LiBr -based absorption chiller can use waste heat or solar energy to produce useful space cooling for small buildings...high wa- ter consumption for heat rejection to the ambient. To alleviate these issues, a novel LiBr - based absorption chiller with cold storage is...proposed in this study. The cold storage includes tanks for storing liquid water and LiBr solution, associated piping, and control devices. The cold
DOE Office of Scientific and Technical Information (OSTI.GOV)
Calise, F.; Dentice d'Accadia, M.; Palombo, A.
2010-03-15
In this paper, a transient simulation model of solar-assisted heating and cooling systems (SHC) is presented. A detailed case study is also discussed, in which three different configurations are considered. In all cases, the SHC system is based on the coupling of evacuated solar collectors with a single-stage LiBr-H{sub 2}O absorption chiller, and a gas-fired boiler is also included for auxiliary heating, only during the winter season. In the first configuration, the cooling capacity of the absorption chiller and the solar collector area are designed on the basis of the maximum cooling load, and an electric chiller is used asmore » the auxiliary cooling system. The second layout is similar to the first one, but, in this case, the absorption chiller and the solar collector area are sized in order to balance only a fraction of the maximum cooling load. Finally, in the third configuration, there is no electric chiller, and the auxiliary gas-fired boiler is also used in summer to feed the absorption chiller, in case of scarce solar irradiation. The simulation model was developed using the TRNSYS software, and included the analysis of the dynamic behaviour of the building in which the SHC systems were supposed to be installed. The building was simulated using a single-lumped capacitance model. An economic model was also developed, in order to assess the operating and capital costs of the systems under analysis. Furthermore, a mixed heuristic-deterministic optimization algorithm was implemented, in order to determine the set of the synthesis/design variables that maximize the energy efficiency of each configuration under analysis. The results of the case study were analyzed on monthly and weekly basis, paying special attention to the energy and monetary flows of the standard and optimized configurations. The results are encouraging as for the potential of energy saving. On the contrary, the SHC systems appear still far from the economic profitability: however, this is notoriously true for the great majority of renewable energy systems. (author)« less
NASA Astrophysics Data System (ADS)
Misenheimer, Corey Thomas
The intermittency of wind and solar power puts strain on electric grids, often forcing carbonbased and nuclear sources of energy to operate in a load-follow mode. Operating nuclear reactors in a load-follow fashion is undesirable due to the associated thermal and mechanical stresses placed on the fuel and other reactor components. Various Thermal Energy Storage (TES) elements and ancillary energy applications can be coupled to nuclear (or renewable) power sources to help absorb grid instabilities caused by daily electric demand changes and renewable intermittency, thereby forming the basis of a candidate Nuclear Hybrid Energy System (NHES). During the warmer months of the year in many parts of the country, facility air-conditioning loads are significant contributors to the increase in the daily peak electric demand. Previous research demonstrated that a stratified chilled-water storage tank can displace peak cooling loads to off-peak hours. Based on these findings, the objective of this work is to evaluate the prospect of using a stratified chilled-water storage tank as a potential TES reservoir for a nuclear reactor in a NHES. This is accomplished by developing time-dependent models of chilled-water system components, including absorption chillers, cooling towers, a storage tank, and facility cooling loads appropriate for a large office space or college campus, as a callable FORTRAN subroutine. The resulting TES model is coupled to a high-fidelity mPower-sized Small Modular Reactor (SMR) Simulator, with the goal of utilizing excess reactor capacity to operate several sizable chillers in order to keep reactor power constant. Chilled-water production via single effect, lithium bromide (LiBr) absorption chillers is primarily examined in this study, although the use of electric chillers is briefly explored. Absorption chillers use hot water or low-pressure steam to drive an absorption-refrigeration cycle. The mathematical framework for a high-fidelity dynamic absorption chiller model is presented. The transient FORTRAN model is grounded on time-dependent mass, species, and energy conservation equations. Due to the vast computational costs of the high-fidelity model, a low-fidelity absorption chiller model is formulated and calibrated to mimic the behavior of the high-fidelity model. Stratified chilled-water storage tank performance is characterized using Computational Fluid Dynamics (CFD). The geometry employed in the CFD model represents a 5-million-gallon storage tank currently in use at a North Carolina college campus. Simulation results reveal the laminar numerical model most closely aligns with actual tank charging and discharging data. A subsequent parametric study corroborates storage tank behavior documented throughout literature and industry. Two absorption chiller configurations are considered. The first involves bypassing lowpressure steam from the low-pressure turbine to absorption chillers during periods of excess reactor capacity in order to keep reactor power constant. Simulation results show steam conditions downstream of the turbine control valves are a strong function of turbine load, and absorption chiller performance is hindered by reduced turbine impulse pressures at reduced turbine demands. A more suitable configuration entails integrating the absorption chillers into a flash vessel system that is thermally coupled to a sensible heat storage system. The sensible heat storage system is able to maintain reactor thermal output constant at 100% and match turbine output with several different electric demand profiles. High-pressure condensate in the sensible heat storage system is dropped across a let-down orifice and flashed in an ideal separator. Generated steam is sent to a bank of absorption chillers. Simulation results show enough steam is available during periods of reduced turbine demand to power four large absorption chillers to charge a 5-million-gallon stratified chilled-water storage tank, which is used to offset cooling loads in an adjacent facility. The coupled TES systems operating in conjunction with an SMR comprise the foundation of a tightly coupled NHES.
NASA Astrophysics Data System (ADS)
Olbricht, Michael; Luke, Andrea
2018-05-01
The design of the absorber of absorption chillers is still subject to great uncertainty since the coupled processes of heat and mass transfer as well as the influence of systemic interactions on the absorption process are not fully understood. Unfortunately, only a few investigations on the transport phenomena in the absorber during operation in an absorption chiller are reported in the literature. Therefore, experimental investigations on the heat and mass transfer during falling film absorption of steam in aqueous LiBr-solution are carried out in an absorber installed in an absorption chiller in this work. An improvement of heat and mass transfer due to the increase in convective effects are observed as the Ref number increases. Furthermore, an improvement of the heat transfer in the absorber with increasing coolant temperature can be identified in the systemic context. This is explained by a corresponding reduction in the average viscosity of the solution in the absorber. A comparison with experimental data from literature obtained from so-called absorber-generator test rigs shows a good consistency. Thus, it has been shown that the findings obtained on these simplified experimental setups can be transferred to the absorber in an absorption chiller. However, a comparison with correlations from the literature reveals a strong deviation between experimental and calculated results. Hence, further research activities on the development of better correlations are required in future.
How gas cools (or, apples can fall up)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1987-01-01
This primer on gas cooling systems explains the basics of heat exchange within a refrigeration system, the principle of reverse-cycle refrigeration, and how a gas-engine-driven heat pump can provide cooling, additional winter heating capacity, and hot water year-round. Gas cooling equipment available or under development include natural gas chillers, engine-driven chillers, and absorption chillers. In cogeneration systems, heat recovered from an engine's exhaust and coolant may be used in an absorption chiller to provide air-conditioning. Gas desiccant cooling systems may be used in buildings and businesses that are sensitive to high humidity levels.
Study of component technologies for fuel cell on-site integrated energy systems
NASA Technical Reports Server (NTRS)
Lee, W. D.; Mathias, S.
1980-01-01
Heating, ventilation and air conditioning equipment are integrated with three types of fuel cells. System design and computer simulations are developed to utilize the thermal energy discharge of the fuel in the most cost effective manner. The fuel provides all of the electric needs and a loss of load probability analysis is used to ensure adequate power plant reliability. Equipment cost is estimated for each of the systems analyzed. A levelized annual cost reflecting owning and operating costs including the cost of money was used to select the most promising integrated system configurations. Cash flows are presented for the most promising 16 systems. Several systems for the 96 unit apartment complex (a retail store was also studied) were cost competitive with both gas and electric based conventional systems. Thermal storage is shown to be beneficial and the optimum absorption chiller sizing (waste heat recovery) in connection with electric chillers are developed. Battery storage was analyzed since the system is not electric grid connected. Advanced absorption chillers were analyzed as well. Recommendations covering financing, technical development, and policy issues are given to accelerate the commercialization of the fuel cell for on-site power generation in buildings.
NASA Astrophysics Data System (ADS)
Hosford, Kyle S.
Clean distributed generation power plants can provide a much needed balance to our energy infrastructure in the future. A high-temperature fuel cell and an absorption chiller can be integrated to create an ideal combined cooling, heat, and power system that is efficient, quiet, fuel flexible, scalable, and environmentally friendly. With few real-world installations of this type, research remains to identify the best integration and operating strategy and to evaluate the economic viability and market potential of this system. This thesis informs and documents the design of a high-temperature fuel cell and absorption chiller demonstration system at a generic office building on the University of California, Irvine (UCI) campus. This work details the extension of prior theoretical work to a financially-viable power purchase agreement (PPA) with regard to system design, equipment sizing, and operating strategy. This work also addresses the metering and monitoring for the system showcase and research and details the development of a MATLAB code to evaluate the economics associated with different equipment selections, building loads, and economic parameters. The series configuration of a high-temperature fuel cell, heat recovery unit, and absorption chiller with chiller exhaust recirculation was identified as the optimal system design for the installation in terms of efficiency, controls, ducting, and cost. The initial economic results show that high-temperature fuel cell and absorption chiller systems are already economically competitive with utility-purchased generation, and a brief case study of a southern California hospital shows that the systems are scalable and viable for larger stationary power applications.
CFCS and electric chillers: Selection of large-capacity water chillers in the 1990s. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Niess, R.C.
1992-03-01
This handbook offers a single source of useful information for understanding CFC and HCFC phaseout issues and selecting large-capacity water chillers for cooling commercial buildings. It evaluates the performance of electric, absorption, and natural-gas-engine driven water chillers. An economic evaluation checklist and example are included, using the EPRI COMTECH screening tool. Peak shaving with gas chillers and load shifting with chilled water storage are examined. The handbook, written for a diverse audience, covers chiller hardware, function, performance, and typical installed costs. It provides guidelines and checklists for chiller selection, economic comparison, and operation and maintenance.
CFCS and electric chillers: Selection of large-capacity water chillers in the 1990s
DOE Office of Scientific and Technical Information (OSTI.GOV)
Niess, R.C.
1992-03-01
This handbook offers a single source of useful information for understanding CFC and HCFC phaseout issues and selecting large-capacity water chillers for cooling commercial buildings. It evaluates the performance of electric, absorption, and natural-gas-engine driven water chillers. An economic evaluation checklist and example are included, using the EPRI COMTECH screening tool. Peak shaving with gas chillers and load shifting with chilled water storage are examined. The handbook, written for a diverse audience, covers chiller hardware, function, performance, and typical installed costs. It provides guidelines and checklists for chiller selection, economic comparison, and operation and maintenance.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-31
...: The U.S. Department of Energy (DOE) has preliminarily determined that wine chillers and other... Wine Chillers 2. Thermoelectric Refrigeration Products 3. Absorption Refrigeration Products V... to separate them from other miscellaneous residential refrigeration products such as wine chillers...
Cycle simulation of the low-temperature triple-effect absorption chiller with vapor compression unit
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, J.S.; Lee, H.
1999-07-01
The construction of a triple-effect absorption chiller machine using the lithium bromide-water solution as a working fluid is strongly limited by corrosion problems caused by the high generator temperature. In this work, three new cycles having the additional vapor compression units were suggested in order to lower the generator temperature of a triple-effect absorption chiller. Each new cycle has one compressor located at the different position which was used to elevate the pressure of the refrigerant vapor. Computer simulations were carried out in order to examine both the basic triple-effect cycle and three new cycles. All types of triple-effect absorptionmore » chiller cycles were found to be able to lower the temperature of high-temperature generator to the more favorable operation range. The COPs of three cycles calculated by considering the additional compressor works showed a small level of decrease or increase compared with that of the basic triple-effect cycle. Consequently, a low-temperature triple-effect absorption chiller can be possibly constructed by adapting one of three new cycles. A great advantage of these new cycles over the basic one is that the conventionally used lithium bromide-water solution can be successfully used as a working fluid without the danger of corrosion.« less
NASA Technical Reports Server (NTRS)
Namkoong, D.
1976-01-01
A three ton lithium bromide absorption water chiller was tested for a number of conditions involving hot water input, chilled water, and the cooling water. The primary influences on chiller capacity were the hot water inlet temperature and the cooling water inlet temperature. One combination of these two parameters extended the output to as much as 125% of design capacity, but no combination could lower the capacity to below 60% of design. A cooling system was conceptually designed so that it could provide several modes of operation. Such flexibility is needed for any solar cooling system to be able to accommodate the varying solar energy collection and the varying building demand. It was concluded that a three-ton absorption water chiller with the kind of performance that was measured can be incorporated into a cooling system such as that proposed, to provide efficient cooling over the specified ranges of operating conditions.
NASA Technical Reports Server (NTRS)
Namkoong, D.
1976-01-01
A 3-ton lithium bromide absorption water chiller was tested for a number of conditions involving hot-water input, chilled water, and the cooling water. The primary influences on chiller capacity were the hot water inlet temperature and the cooling water inlet temperature. One combination of these two parameters extended the output to as much as 125% of design capacity, but no combination could lower the capacity to below 60% of design. A cooling system was conceptually designed so that it could provide several modes of operation. Such flexibility is needed for any solar cooling system to be able to accommodate the varying solar energy collection and the varying building demand. It is concluded that a 3-ton absorption water chiller with the kind of performance that was measured can be incorporated into a cooling system such as that proposed, to provide efficient cooling over the specified ranges of operating conditions.
Evaluation of solar thermal driven cooling system in office buildings in Saudi Arabia
NASA Astrophysics Data System (ADS)
Linjawi, Majid T.; Talal, Qazi; Al-Sulaiman, Fahad A.
2017-11-01
In this study solar driven absorption chiller is used to reduce the peak cooling load in office buildings in Saudi Arabia for different selected cities. The study is conducted for six cities of Abha, Dhahran, Hail, Jeddah, Nejran and Riyadh under three operating durations of 4, 6, and 8 hours using flat plate or evacuated tube collectors. The energy analysis concluded that flat plate collectors are better than evacuated tube collectors. However, the results from economic analysis suggest that while proposing a gas fired absorption chiller will reduce running costs, further reduction by using solar collectors is not feasible because of its high initial cost. At the best case scenario the Net Present Value of a 10 Ton Absorption chiller operated by natural gas boiler and two large flat plate collectors (12m2 each) running for 8 hours/day, 5days/week has a value of 117,000 and Internal Rate of Return (IRR) of 12%. Solar driven absorption chiller could be more feasible if the gas prices increases or the solar collector prices decreases significantly. Finally, government economic incentives and taxes are recommended to provide a boost for the feasibility of such projects.
40 CFR 1066.135 - Linearity verification.
Code of Federal Regulations, 2014 CFR
2014-07-01
... CVS, double-dilution, and partial-flow systems. (3) PM sample. (4) Chiller sample, for gaseous sampling systems that use thermal chillers to dry samples, and that use chiller temperature to calculate dewpoint at the chiller outlet. For testing, if you choose to use the high alarm temperature setpoint for...
NASA Astrophysics Data System (ADS)
Mysore, Abhishek Arun Babu
A medium data center consists of servers performing operations such as file sharing, collaboration and email. There are a large number of small and medium data centers across the world which consume more energy and are less efficient when compared to large data center facilities of companies such as GOOGLE, APPLE and FACEBOOK. Such companies are making their data center facilities more environmental friendly by employing renewable energy solutions such as wind and solar to power the data center or in data center cooling. This not only reduces the carbon footprint significantly but also decreases the costs incurred over a period of time. Cooling of data center play a vital role in proper functioning of the servers. It is found that cooling consumes about 50% of the total power consumed by the data center. Traditional method of cooling includes the use of mechanical compression chillers which consume lot of power and is not desirable. In order to eliminate the use of mechanical compressor chillers renewable energy resources such as solar and wind should be employed. One such technology is solar thermal cooling by means of absorption chiller which is powered by solar energy. The absorption chiller unit can be coupled with either flat plate or evacuated tube collectors in order to achieve the required inlet temperature for the generator of the absorption chiller unit. In this study a modular data center is considered having a cooling load requirement of 23kw. The performance characteristics of a single stage Lithium Bromide/ water refrigeration is presented in this study considering the cooling load of 23kw. Performance characteristics of each of the 4 heat exchangers within the unit is discussed which helps in customizing the unit according to the users' specific needs. This analysis helps in studying the importance of different properties such as the effect of inlet temperatures of hot water for generator, inlet temperatures of cooling water for absorber and condenser and outlet chilled water temperatures of the evaporator.
NASA Astrophysics Data System (ADS)
Song, Jinghui; Yuan, Hui; Xia, Yunfeng; Kan, Weimin; Deng, Xiaowen; Liu, Shi; Liang, Wanlong; Deng, Jianhua
2018-03-01
This paper introduces the working principle and system constitution of the linear Fresnel solar lithium bromide absorption refrigeration cycle, and elaborates several typical structures of absorption refrigeration cycle, including single-effect, two-stage cycle and double-effect lithium bromide absorption refrigeration cycle A 1.n effect absorption chiller system based on the best parameters was introduced and applied to a linear Fresnel solar absorption chiller system. Through the field refrigerator performance test, the results show: Based on this heat cycle design and processing 1.n lithium bromide absorption refrigeration power up to 35.2KW, It can meet the theoretical expectations and has good flexibility and reliability, provides guidance for the use of solar thermal energy.
Rethinking chiller plant design
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meckler, M.
1998-07-01
While most refrigeration chillers operate today on electricity, the use of natural gas is becoming an increasingly attractive alternative. This is largely because electricity does not use energy very efficiency (because of transmission and combustion fuel losses), high demand charges, and the high incremental cost of electricity to operate chillers. The use of gas engine-driven chillers eliminates the high incremental cost of electricity. Additionally, gas engine-driven systems can operate with COPs up to 1.8 and, therefore, are economically viable alternatives. Recent advances in gas engine-driven and DFA absorption chillers, and in commercially viable solid and liquid desiccant-cooling systems, suggest amore » bright future for the gas industry. The use of such equipment in conjunction with or in place of commercially available electrical-powered alternatives can significantly impact demand-side management savings for utility ratepayers in the short run and provide significant hybrid opportunities for deregulated markets in the intermediate to long term.« less
Rethinking chiller plant design
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meckler, M.
1998-01-01
While most refrigeration chillers operate today on electricity, the use of natural gas is becoming an increasingly attractive alternative. This is largely because electricity does not use energy very efficiently (due to transmission and combustion fuel losses), high demand charges, and the high incremental cost of electricity to operate chillers. The use of gas engine-driven chillers eliminates the high incremental cost of electricity. Additionally, gas engine-driven systems can operate with COPs up to 1.8 and therefore are economically viable alternatives. Recent advances in gas engine-driven and direct-fired absorption chillers and in commercially viable solid- and liquid-desiccant cooling systems suggest amore » bright future for the gas industry. The use of such equipment in conjunction with or in place of commercially available electrical-powered alternatives can significantly impact demand-side management savings for utility ratepayers in the short run and provide significant hybrid opportunities for deregulated markets in the intermediate to long term.« less
Triple-effect absorption chiller cycle: A step beyond double-effect cycles
DOE Office of Scientific and Technical Information (OSTI.GOV)
DeVault, R.C.
1990-01-01
Many advanced'' absorption cycles have been proposed during the current century. Of the hundreds of absorption cycles which have been patented throughout the world, all commercially manufactured products for air conditioning buildings have been variations of just two basic absorption cycles: single-effect and condenser-coupled double-effect cycles. The relatively low cooling coefficients of performance (COPs) inherent in single-effect and double-effect cycles limits the economic applicability of absorption air conditioners (chillers) in the United States. A triple-effect absorption chiller cycle is discussed. This cycle uses two condensers and two absorbers to achieve the triple effect.'' Depending on the absorption fluids selected, thismore » triple-effect cycle is predicted to improve cooling COPs by 18% to 60% compared with the equivalent double-effect cycle. This performance improvement is obtained without increasing the total amount of heat-transfer surface area needed for the heat exchangers. A comparison between the calculated performances of a double-effect cycle and a triple-effect cycle (both using ammonia-water (NH{sub 3}/H{sub 2}O) as the absorption fluid pair) is presented. The triple-effect cycle is predicted to have an 18% higher cooling COP (1.41 compared with 1.2 for a double-effect), lower pressure (47.70 atm (701 psi) instead of 68.05 atm (1000 psi)), significantly reduced pumping power (less than one-half that of the double-effect cycle), and potentially lower construction cost (33% less total heat exchange needed). Practical implications for this triple-effect cycle are discussed. 16 refs., 5 figs., 1 tab.« less
Analysis of advanced conceptual designs for single-family-size absorption chillers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Macriss, R.A.; Zawacki, T.S.; Kouo, M.T.
1978-01-01
The objective of this research study is the development of radically new fluid systems, specifically tailored to the needs and requirements of solar-absorption cooling for single-family-size residences. Progress is reported.
Evaluation of Aqua-Ammonia Chiller Technologies and Field Site Installation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zaltash, Abdolreza
2007-09-01
The Naval Facilities Engineering Service Center (NFESC) has sponsored Oak Ridge National Laboratory (ORNL) to review, select, and evaluate advanced, gas-fired, 5-ton, aqua-ammonia, chiller technologies. The selection criteria was that units have COP values of 0.67 or better at Air-conditioning and Refrigeration Institute (ARI) 95 F outdoor rating conditions, an active refrigerant flow control, and a variable-speed condenser fan. These features are expected to allow these units to operate at higher ambient temperatures (up to the maximum operating temperature of 110 F) with minimal degradation in performance. ORNL evaluated three potential manufacturers of advanced, gas-fired, 5-ton, aqua-ammonia chillers-Robur, Ambian, andmore » Cooling Technologies. Unfortunately, Robur did not meet the COP requirements and Cooling Technologies could not deliver a unit to be tested at the U.S. Department of Energy (DOE)-ORNL environmental chamber testing facility for thermally activated heat pumps. This eliminated these two technologies from further consideration, leaving only the Ambian chillers for evaluation. Two Ambian chillers were evaluated at the DOE-ORNL test facility. Overall these chillers operated well over a wide range of ambient conditions with minimal degradation in performance due to several control strategies used such as a variable speed condenser fan, a modulating burner, and active refrigerant flow control. These Ambian pre-commercial units were selected for installation and field testing at three federal facilities. NFESC worked with ORNL to assist with the site selection for installation and evaluation of these chillers. Two sites (ORNL and Naval Surface Warfare Center [NSWC] Corona) had a single chiller unit installed; and at one site (Naval Amphibious Base [NAB] Little Creek), two 5-ton chillers linked together were installed to provide 10 tons of cooling. A chiller link controller developed under this project was evaluated in the field test at Little Creek.« less
Triple effect absorption chiller utilizing two refrigeration circuits
DeVault, Robert C.
1988-01-01
A triple effect absorption method and apparatus having a high coefficient of performance. Two single effect absorption circuits are combined with heat exchange occurring between a condenser and absorber of a high temperature circuit, and a generator of a low temperature circuit. The evaporators of both the high and low temperature circuits provide cooling to an external heat load.
Current fluctuations in quantum absorption refrigerators
NASA Astrophysics Data System (ADS)
Segal, Dvira
2018-05-01
Absorption refrigerators transfer thermal energy from a cold bath to a hot bath without input power by utilizing heat from an additional "work" reservoir. Particularly interesting is a three-level design for a quantum absorption refrigerator, which can be optimized to reach the maximal (Carnot) cooling efficiency. Previous studies of three-level chillers focused on the behavior of the averaged cooling current. Here, we go beyond that and study the full counting statistics of heat exchange in a three-level chiller model. We explain how to obtain the complete cumulant generating function of the refrigerator in a steady state, then derive a partial cumulant generating function, which yields closed-form expressions for both the averaged cooling current and its noise. Our analytical results and simulations are beneficial for the design of nanoscale engines and cooling systems far from equilibrium, with their performance optimized according to different criteria, efficiency, power, fluctuations, and dissipation.
Simulation model of stratified thermal energy storage tank using finite difference method
NASA Astrophysics Data System (ADS)
Waluyo, Joko
2016-06-01
Stratified TES tank is normally used in the cogeneration plant. The stratified TES tanks are simple, low cost, and equal or superior in thermal performance. The advantage of TES tank is that it enables shifting of energy usage from off-peak demand for on-peak demand requirement. To increase energy utilization in a stratified TES tank, it is required to build a simulation model which capable to simulate the charging phenomenon in the stratified TES tank precisely. This paper is aimed to develop a novel model in addressing the aforementioned problem. The model incorporated chiller into the charging of stratified TES tank system in a closed system. The model was developed in one-dimensional type involve with heat transfer aspect. The model covers the main factors affect to degradation of temperature distribution namely conduction through the tank wall, conduction between cool and warm water, mixing effect on the initial flow of the charging as well as heat loss to surrounding. The simulation model is developed based on finite difference method utilizing buffer concept theory and solved in explicit method. Validation of the simulation model is carried out using observed data obtained from operating stratified TES tank in cogeneration plant. The temperature distribution of the model capable of representing S-curve pattern as well as simulating decreased charging temperature after reaching full condition. The coefficient of determination values between the observed data and model obtained higher than 0.88. Meaning that the model has capability in simulating the charging phenomenon in the stratified TES tank. The model is not only capable of generating temperature distribution but also can be enhanced for representing transient condition during the charging of stratified TES tank. This successful model can be addressed for solving the limitation temperature occurs in charging of the stratified TES tank with the absorption chiller. Further, the stratified TES tank can be charged with the cooling energy of absorption chiller that utilizes from waste heat from gas turbine of the cogeneration plant.
Theoretical and testing performance of an innovative indirect evaporative chiller
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jiang, Yi; Xie, Xiaoyun
2010-12-15
An indirect evaporative chiller is a device used to produce chilled water at a temperature between the wet bulb temperature and dew point of the outdoor air, which can be used in building HVAC systems. This article presents a theoretical analysis and practical performance of an innovative indirect evaporative chiller. First, the process of the indirect evaporative chiller is introduced; then, the matching characteristics of the process are presented and analyzed. It can be shown that the process that produces cold water by using dry air is a nearly-reversible process, so the ideal produced chilled water temperature of the indirectmore » evaporative chiller can be set close to the dew point temperature of the chiller's inlet air. After the indirect evaporative chiller was designed, simulations were done to analyze the output water temperature, the cooling efficiency relative to the inlet dew point temperature, and the COP that the chiller can performance. The first installation of the indirect evaporative chiller of this kind has been run for 5 years in a building in the city of Shihezi. The tested output water temperature of the chiller is around 14-20 C, which is just in between of the outdoor wet bulb temperature and dew point. The tested COP{sub r,s} of the developed indirect evaporative chiller reaches 9.1. Compared with ordinary air conditioning systems, the indirect evaporative chiller can save more than 40% in energy consumption due to the fact that the only energy consumed is from pumps and fans. An added bonus is that the indirect evaporative chiller uses no CFCs that pollute to the aerosphere. The tested internal parameters, such as the water-air flow rate ratio and heat transfer area for each heat transfer process inside the chiller, were analyzed and compared with designed values. The tested indoor air conditions, with a room temperature of 23-27 C and relative humidity of 50-70%, proved that the developed practical indirect evaporative chiller successfully satisfy the indoor air conditioning load for the demo building. The indirect evaporative chiller has a potentially wide application in dry regions, especially for large scale commercial buildings. Finally, this paper presented the geographic regions suitable for the technology worldwide. (author)« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
A partial acceptance test was conducted on the El Toro Library Solar Energy System, and the detailed results of the various mode acceptance tests are given. All the modes tested function as designed. Collector array efficiencies were calculated at approximately 40%. Chiller COP was estimated at .50, with chiller loop flow rates approximately 85 to 90% of design flow. The acceptance test included visual inspection, preoperational testing and procedure verification, operational mode checkout, and performance testing. (LEW)
Chiller Controls-related Energy Saving Opportunities in FederalFacilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Webster, Tom
2003-01-01
Chillers are a significant component of large facility energy use. The focus of much of the development of chilled water systems in recent years has been on optimization of set point and staging controls, improvements in chiller design to increase efficiency and accommodate chlorofluorocarbon (CFC) refrigerant replacements. Other improvements have been made by upgrading controls to the latest digital technologies, improving access and monitoring via communications and sophisticated liquid crystal displays (LCD), more robust fault diagnostics and operating and maintenance information logging. Advances have also been made in how chiller plant systems are designed and operated, and in the diversitymore » of chiller products that are available to support innovative approaches. As in many industries, these improvements have been facilitated by advances in, and lower costs for, enabling technologies, such as refrigerants, compressor design, electronics for controls and variable frequency drives (VFD). Along with the improvements in electronics one would expect that advances have also been made in the functionality of unit controls included with chillers. Originally, the primary purpose of this project was to investigate the state of practice of chiller unit controllers in terms of their energy saving capabilities. However, early in the study it was discovered that advances in this area did not include incorporation of significantly different capabilities than had existed 10-15 years ago. Thus the scope has been modified to provide an overview of some of the basic controls-related energy saving strategies that are currently available along with guideline estimates of their potential and applicability. We have minimized consideration of strategies that could be primarily implemented via design practices such as chiller selection and plant design, and those that can only be implemented by a building management system (BMS). Also, since most of the floor space of federal buildings occurs in large buildings, we have focused on water-cooled screw and centrifugal chillers of 100 ton capacity and greater. However, the role of reciprocating and gas chillers (absorption and engine driven) is discussed briefly. Understanding the demographics of chiller deployment in the federal sector, state of practice of energy savings strategies and control features availability will help federal energy managers and program implementers to make informed decisions in support of energy saving performance contracting (ESPC) and other programs.« less
Combined solar collector and energy storage system
NASA Technical Reports Server (NTRS)
Jensen, R. N. (Inventor)
1980-01-01
A combined solar energy collector, fluid chiller and energy storage system is disclosed. A movable interior insulated panel in a storage tank is positionable flush against the storage tank wall to insulate the tank for energy storage. The movable interior insulated panel is alternately positionable to form a solar collector or fluid chiller through which the fluid flows by natural circulation.
Scoring LEED® Points with CHP (Webinar) – July 21, 2015
This webinar provides information about how to earn points with CHP in the LEED green building rating system, describes modern absorption chillers and their role with CHP and LEED, and presents case studies.
INNOVATIVE HYBRID GAS/ELECTRIC CHILLER COGENERATION
DOE Office of Scientific and Technical Information (OSTI.GOV)
Todd Kollross; Mike Connolly
2004-06-30
Engine-driven chillers are quickly gaining popularity in the market place (increased from 7,000 tons in 1994 to greater than 50,000 tons in 1998) due to their high efficiency, electric peak shaving capability, and overall low operating cost. The product offers attractive economics (5 year pay back or less) in many applications, based on areas cooling requirements and electric pricing structure. When heat is recovered and utilized from the engine, the energy resource efficiency of a natural gas engine-driven chiller is higher than all competing products. As deregulation proceeds, real time pricing rate structures promise high peak demand electric rates, butmore » low off-peak electric rates. An emerging trend with commercial building owners and managers who require air conditioning today is to reduce their operating costs by installing hybrid chiller systems that combine gas and electric units. Hybrid systems not only reduce peak electric demand charges, but also allow customers to level their energy load profiles and select the most economical energy source, gas or electricity, from hour to hour. Until recently, however, all hybrid systems incorporated one or more gas-powered chillers (engine driven and/or absorption) and one or more conventional electric units. Typically, the cooling capacity of hybrid chiller plants ranges from the hundreds to thousands of refrigeration tons, with multiple chillers affording the user a choice of cooling systems. But this flexibility is less of an option for building operators who have limited room for equipment. To address this technology gap, a hybrid chiller was developed by Alturdyne that combines a gas engine, an electric motor and a refrigeration compressor within a single package. However, this product had not been designed to realize the full features and benefits possible by combining an engine, motor/generator and compressor. The purpose of this project is to develop a new hybrid chiller that can (1) reduce end-user energy costs, (2) lower building peak electric load, (3) increase energy efficiency, and (4) provide standby power. This new hybrid product is designed to allow the engine to generate electricity or drive the chiller's compressor, based on the market price and conditions of the available energy sources. Building owners can minimize cooling costs by operating with natural gas or electricity, depending on time of day energy rates. In the event of a backout, the building owner could either operate the product as a synchronous generator set, thus providing standby power, or continue to operate a chiller to provide air conditioning with support of a small generator set to cover the chiller's electric auxiliary requirements. The ability to utilize the same piece of equipment as a hybrid gas/electric chiller or a standby generator greatly enhances its economic attractiveness and would substantially expand the opportunities for high efficiency cooling products.« less
NASA Astrophysics Data System (ADS)
Cola, Fabrizio; Romagnoli, Alessandro; Hey, Jonathan
2018-05-01
Absorber downsizing for the development of compact absorption chillers is a known challenge of this type of refrigerator. Past studies have revealed how a droplet flow regime can increase the interface area and enhance absorption rates, especially during the droplet formation. This study proposes a space-efficient design for an adiabatic absorber based on a bank of solid pins coupled with a droplet flow regime. Manufacturing through 3D printing technique is used to study the effect of different fin shapes during droplet formation. Droplet behavior is firstly studied analytically through a variational approach. Experiments on pure water are then carried out to validate the model and produce design guidelines for a H2O-LiBr absorber. Results show that the analytical model is more accurate in the regions close to the droplet bottom. The rhomboidal geometry with 120° returned the smallest droplet volume without allowing coalescence of more droplets, ensuring the maintenance of droplet flow and a high surface area for mass transfer. Disturbances in the droplet profiles were observed, caused by the pin-droplet interaction. A map has been then created to allow a quick sizing of the absorber and find its main geometrical and operational features.
NASA Astrophysics Data System (ADS)
Wojdyga, Krzysztof; Malicki, Marcin
2017-11-01
Constant strive to improve the energy efficiency forces carrying out activities aimed at reduction of energy consumption hence decreasing amount of contamination emissions to atmosphere. Cooling demand, both for air-conditioning and process cooling, plays an increasingly important role in the balance of Polish electricity generation and distribution system in summer. During recent years' demand for electricity during summer months has been steadily and significantly increasing leading to deficits of energy availability during particularly hot periods. This causes growing importance and interest in trigeneration power generation sources and heat recovery systems producing chilled water. Key component of such system is thermally driven chiller, mostly absorption, based on lithium-bromide and water mixture. Absorption cooling systems also exist in Poland as stand-alone systems, supplied with heating from various sources, generated solely for them or recovered as waste or useless energy. The publication presents a simple algorithm, designed to reduce the amount of heat for the supply of absorption chillers producing chilled water for the purposes of air conditioning by reducing the temperature of the cooling water, and its impact on decreasing emissions of harmful substances into the atmosphere. Scale of environmental advantages has been rated for specific sources what enabled evaluation and estimation of simple algorithm implementation to sources existing nationally.
NASA Astrophysics Data System (ADS)
Javed, Hassan; Armstrong, Peter
2015-08-01
The efficiency bar for a Minimum Equipment Performance Standard (MEPS) generally aims to minimize energy consumption and life cycle cost of a given chiller type and size category serving a typical load profile. Compressor type has a significant chiller performance impact. Performance of screw and reciprocating compressors is expressed in terms of pressure ratio and speed for a given refrigerant and suction density. Isentropic efficiency for a screw compressor is strongly affected by under- and over-compression (UOC) processes. The theoretical simple physical UOC model involves a compressor-specific (but sometimes unknown) volume index parameter and the real gas properties of the refrigerant used. Isentropic efficiency is estimated by the UOC model and a bi-cubic, used to account for flow, friction and electrical losses. The unknown volume index, a smoothing parameter (to flatten the UOC model peak) and bi-cubic coefficients are identified by curve fitting to minimize an appropriate residual norm. Chiller performance maps are produced for each compressor type by selecting optimized sub-cooling and condenser fan speed options in a generic component-based chiller model. SEER is the sum of hourly load (from a typical building in the climate of interest) and specific power for the same hourly conditions. An empirical UAE cooling load model, scalable to any equipment capacity, is used to establish proposed UAE MEPS. Annual electricity use and cost, determined from SEER and annual cooling load, and chiller component cost data are used to find optimal chiller designs and perform life-cycle cost comparison between screw and reciprocating compressor-based chillers. This process may be applied to any climate/load model in order to establish optimized MEPS for any country and/or region.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haves, Phillip; Hencey, Brandon; Borrell, Francesco
2010-06-29
A Model Predictive Control algorithm was developed for the UC Merced campus chilled water plant. Model predictive control (MPC) is an advanced control technology that has proven successful in the chemical process industry and other industries. The main goal of the research was to demonstrate the practical and commercial viability of MPC for optimization of building energy systems. The control algorithms were developed and implemented in MATLAB, allowing for rapid development, performance, and robustness assessment. The UC Merced chilled water plant includes three water-cooled chillers and a two million gallon chilled water storage tank. The tank is charged during themore » night to minimize on-peak electricity consumption and take advantage of the lower ambient wet bulb temperature. The control algorithms determined the optimal chilled water plant operation including chilled water supply (CHWS) temperature set-point, condenser water supply (CWS) temperature set-point and the charging start and stop times to minimize a cost function that includes energy consumption and peak electrical demand over a 3-day prediction horizon. A detailed model of the chilled water plant and simplified models of the buildings served by the plant were developed using the equation-based modeling language Modelica. Steady state models of the chillers, cooling towers and pumps were developed, based on manufacturers performance data, and calibrated using measured data collected and archived by the control system. A detailed dynamic model of the chilled water storage tank was also developed and calibrated. Simple, semi-empirical models were developed to predict the temperature and flow rate of the chilled water returning to the plant from the buildings. These models were then combined and simplified for use in a model predictive control algorithm that determines the optimal chiller start and stop times and set-points for the condenser water temperature and the chilled water supply temperature. The report describes the development and testing of the algorithm and evaluates the resulting performance, concluding with a discussion of next steps in further research. The experimental results show a small improvement in COP over the baseline policy but it is difficult to draw any strong conclusions about the energy savings potential for MPC with this system only four days of suitable experimental data were obtained once correct operation of the MPC system had been achieved. These data show an improvement in COP of 3.1% {+-} 2.2% relative to a baseline established immediately prior to the period when the MPC was run in its final form. This baseline includes control policy improvements that the plant operators learned by observing the earlier implementations of MPC, including increasing the temperature of the water supplied to the chiller condensers from the cooling towers. The process of data collection and model development, necessary for any MPC project, resulted in the team uncovering various problems with the chilled water system. Although it is difficult to quantify the energy savings resulting from these problems being remedied, they were likely on the same order as the energy savings from the MPC itself. Although the types of problems uncovered and the level of energy savings may differ significantly from other projects, some of the benefits of detecting and diagnosing problems are expected from the use of MPC for any chilled water plant. The degree of chiller loading was found to be a key factor for efficiency. It is more efficient to operate the chillers at or near full load. In order to maximize the chiller load, one would maximize the temperature difference across chillers and the chilled water flow rate through the chillers. Thus, the CHWS set-point and the chilled water flow-rate can be used to limit the chiller loading to prevent chiller surging. Since the flow rate has an upper bound and the CHWS set point has a lower bound, the chiller loading is constrained and often determined by the chilled water return temperature (CHWR). The CHWR temperature is primarily comprised of warm water from the top of the TES tank. The CHWR temperature falls substantially as the thermocline approaches the top of the tank, which reduces the chiller loading. As a result, it has been determined that overcharging the TES tank can be detrimental to the chilled water plant efficiency. The resulting MPC policy differs from the current practice of fully charging the TES tank. A heuristic rule could possible avoid this problem without using predictive control. Similarly, the COP improvements from the change in CWS set-point were largely captured by a static set-point change by the operators. Further research is required to determine how much of the MPC savings could be garnered through simplified rules (based on the MPC study), with and without prediction.« less
Calculation tool for transported geothermal energy using two-step absorption process
Kyle Gluesenkamp
2016-02-01
This spreadsheet allows the user to calculate parameters relevant to techno-economic performance of a two-step absorption process to transport low temperature geothermal heat some distance (1-20 miles) for use in building air conditioning. The parameters included are (1) energy density of aqueous LiBr and LiCl solutions, (2) transportation cost of trucking solution, and (3) equipment cost for the required chillers and cooling towers in the two-step absorption approach. More information is available in the included public report: "A Technical and Economic Analysis of an Innovative Two-Step Absorption System for Utilizing Low-Temperature Geothermal Resources to Condition Commercial Buildings"
Performance and operational analysis of a liquid desiccant open-flow solar collector
NASA Astrophysics Data System (ADS)
Grodzka, P. G.; Rico, S. S.
1982-10-01
Theoretical predictions of the heat and mass transfer in an open flow solar collector used in conjunction with an absorption chiller are compared with performance data from a rooftop system. The study focuses on aqueous solutions of a hygroscopic salt, e.g., LiCl, flowing continuously over a solar absorbing surface. Water in the solution sublimes to a region of lower vapor pressure, i.e., the atmosphere. Direction of the water-depleted dessiccant to a storage volume and then to circulation around an evaporator unit permits operation of a solar-powered air conditioner. A closed form solution was defined for the heat and mass transfer, along with a finite difference solution. The system studied comprised a sloped roof top with 2500 sq ft of asphalt shingles, collector pipes beneath the shingles, and two 500 gal storage tanks. Relatively good agreement was found between the models and the recorded data, although some discrepancies were present when considering temperatures and performance at specific times of day. The measured 30-40% efficiencies indicated that further development of the system is warranted.
Preconcentrator with high volume chiller for high vapor pressure particle detection
Linker, Kevin L
2013-10-22
Apparatus and method for collecting particles of both high and low vapor pressure target materials entrained in a large volume sample gas stream. Large volume active cooling provides a cold air supply which is mixed with the sample gas stream to reduce the vapor pressure of the particles. In embodiments, a chiller cools air from ambient conditions to 0-15.degree. C. with the volumetric flow rate of the cold air supply being at least equal to the volumetric flow rate of the sample gas stream. In further embodiments an adsorption media is heated in at least two stages, a first of which is below a threshold temperature at which decomposition products of the high vapor pressure particle are generated.
The immediate goal is a system based on the integration of the suite of modules developed solar thermal, biogas, ORC, absorption-chiller) that can be assembled together to create systems tailored to the unique demands of individual communities and climates, optimized for effic...
Solar-Heated and Cooled Office Building--Columbus, Ohio
NASA Technical Reports Server (NTRS)
1982-01-01
Final report documents solar-energy system installed in office building to provide space heating, space cooling and domestic hot water. Collectors mounted on roof track Sun and concentrate rays on fluid-circulating tubes. Collected energy is distributed to hot-water-fired absorption chiller and space-heating and domestic-hot-water preheating systems.
NASA Astrophysics Data System (ADS)
Ghaebi, Hadi; Abbaspour, Ghader
2018-05-01
In this research, thermoeconomic analysis of a multi-effect desalination thermal vapor compression (MED-TVC) system integrated with a trigeneration system with a gas turbine prime mover is carried out. The integrated system comprises of a compressor, a combustion chamber, a gas turbine, a triple-pressure (low, medium and high pressures) heat recovery steam generator (HRSG) system, an absorption chiller cycle (ACC), and a multi-effect desalination (MED) system. Low pressure steam produced in the HRSG is used to drive absorption chiller cycle, medium pressure is used in desalination system and high pressure superheated steam is used for heating purposes. For thermodynamic and thermoeconomic analysis of the proposed integrated system, Engineering Equation Solver (EES) is used by employing mass, energy, exergy, and cost balance equations for each component of system. The results of the modeling showed that with the new design, the exergy efficiency in the base design will increase to 57.5%. In addition, thermoeconomic analysis revealed that the net power, heating, fresh water and cooling have the highest production cost, respectively.
Solar Energy system performance evaluation: El Toro, California, March 1981-November 1981
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pakkala, P.A.
The El Toro Library is a public library facility in California with an active solar energy system designed to supply 97% of the heating load and 60% of the cooling load. The system is equipped with 1427 square feet of evacuated tube collectors, a 1500-gallon steel storage tank, and an auxiliary natural-gas-fired heating unit. During the period from March 1981 through November 1981 the system supplied only 16% of the space cooling load, far short of the 60% design value. Problems are reported related to control of a valve and of collection, low absorption chiller coefficient of performance during partmore » of the period, and small collector area. Performance data are reported for the system, including solar savings ratio, conventional fuel savings, system performance factor, system coefficient of performance, solar energy utilization, and system operation. Subsystem performance data are also given for the collector, storage, and space cooling subsystems and absorption chiller. The system is briefly described along with performance evaluation techniques and sensors, and typical data are presented for one month. Some weather data are also included. (LEW)« less
Evaporatively cooled chiller for solar air conditioning systems design and field test
NASA Astrophysics Data System (ADS)
Merrick, R. H.; Murray, J. G.
1984-06-01
Design changes to improve reliability, part load performance, and manufacturability characteristics of the chiller are focused upon. Low heat flux was achieved by large transfer area allows scale formation without being a thermal barrier: 80 mils = 1 deg. The scaling rate is minimized by keeping surface temperatures below 100 F and a generous water recirculation flow rate. By integrating the cooling tower function into the chiller itself parasitic power consumption was reduced 35%. This system also provided the winter freeze protection without the specific manual shut down procedures required by separate water cooled units and their towers. The severe reduction in cumulative coefficient of performance (COP) due to cycling conditions has been substantially reduced using the spin down control scheme. The major disappointment was the failure to develop a satisfactory inexpensive protective coating. Hot dip galvanizing was demonstrated to be effective but costly, partially due to transportation expense.
Economic optimization software applied to JFK airport heating and cooling plant
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gay, R.R.; McCoy, L.
This paper describes the on-line economic optimization routine developed by Enter Software, Inc. for application at the heating and cooling plant for the JFK International Airport near New York City. The objective of the economic optimization is to find the optimum plant configuration (which gas turbines to run, power levels of each gas turbine, duct firing levels, which auxiliary water heaters to run, which electric chillers to run, and which absorption chillers to run) which produces maximum net income at the plant as plant loads and the prices vary. The routines also include a planner which runs a series ofmore » optimizations over multiple plant configurations to simulate the varying plant operating conditions for the purpose of predicting the overall plant results over a period of time.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-09
... Temperature Thermostat (range of 15-55 Fahrenheit, automatic reset); (3) Two-stage, steam heated absorption chillers rated at 450 tons; and (4) 4 Watt 325 lumen dock lamp LED replacement bulbs. DATES: Effective Date...), the head of a Federal department or agency may issue a ``determination of inapplicability'' (a waiver...
Solar cooling - comparative study between thermal and electrical use in industrial buildings
NASA Astrophysics Data System (ADS)
Badea, N.; Badea, G. V.; Epureanu, A.; Frumuşanu, G.
2016-08-01
The increase in the share of renewable energy sources together with the emphasis on the need for energy security bring to a spotlight the field of trigeneration autonomous microsystems, as a solution to cover the energy consumptions, not only for isolated industrial buildings, but also for industrial buildings located in urban areas. The use of solar energy for cooling has been taken into account to offer a cooling comfort in the building. Cooling and air- conditioned production are current applications promoting the use of solar energy technologies. Solar cooling systems can be classified, depending on the used energy, in electrical systems using mechanical compression chillers and systems using thermal compression by absorption or adsorption. This comparative study presents the main strengths and weaknesses of solar cooling obtained: i) through the transformation of heat resulted from thermal solar panels combined with adsorption chillers, and ii) through the multiple conversion of electricity - photovoltaic panels - battery - inverter - combined with mechanical compression chillers. Both solutions are analyzed from the standpoints of energy efficiency, dynamic performances (demand response), and costs sizes. At the end of the paper, experimental results obtained in the climatic condition of Galafi city, Romania, are presented.
Economic analysis of solar assisted absorption chiller for a commercial building
NASA Astrophysics Data System (ADS)
Antonyraj, Gnananesan
Dwindling fossil fuels coupled with changes in global climate intensified the drive to make use of renewable energy resources that have negligible impact on the environment. In this attempt, the industrial community produced various devices and systems to make use of solar energy for heating and cooling of building space as well as generate electric power. The most common components employed for collection of solar energy are the flat plate and evacuated tube collectors that produce hot water that can be employed for heating the building space. In order to cool the building, the absorption chiller is commonly employed that requires hot water at high temperatures for its operation. This thesis deals with economic analysis of solar collector and absorption cooling system to meet the building loads of a commercial building located in Chattanooga, Tennessee. Computer simulations are employed to predict the hourly building loads and performance of the flat plate and evacuated tube solar collectors using the hourly weather data. The key variables affecting the economic evaluation of such system are identified and the influence of these parameters is presented. The results of this investigation show that the flat plate solar collectors yield lower payback period compared to the evacuated tube collectors and economic incentives offered by the local and federal agencies play a major role in lowering the payback period.
Experiences in solar cooling systems
NASA Astrophysics Data System (ADS)
Ward, D. S.
The results of performance evaluations for nine solar cooling systems are presented, and reasons fow low or high net energy balances are discussed. Six of the nine systems are noted to have performed unfavorably compared to standard cooling systems due to thermal storage losses, excessive system electrical demands, inappropriate control strategies, poor system-to-load matching, and poor chiller performance. A reduction in heat losses in one residential unit increased the total system efficiency by 2.5%, while eliminating heat losses to the building interior increased the efficiency by 3.3%. The best system incorporated a lithium bromide absorption chiller and a Rankine cycle compression unit for a commercial application. Improvements in the cooling tower and fan configurations to increase the solar cooling system efficiency are indicated. Best performances are expected to occur in climates inducing high annual cooling loads.
Electric chiller handbook. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-02-01
Electric chillers have dominated the market for large commercial cooling systems due to their history of reliable, economical operation. The phaseout of CFCs and deregulation of the utility industry are two factors that significantly impact the chiller market. The CFC phaseout is resulting in the upgrading or replacement of thousands of electric chillers nationwide. In a deregulated environment, utilities are finding increasing need to provide services that can win and retain new customers. Utility representatives need current information on applying and selecting cost-effective chiller systems. The objective of this report was to develop a comprehensive handbook that helps utility technicalmore » and marketing staff, their customers, and design professionals evaluate and select the best options for chilled-water systems in commercial buildings. Investigators used a variety of industry data sources to develop market-share information for electric and gas chiller systems and to determine applications according to building age, type, and region. Discussions with chiller manufacturers provided information on product availability, performance, and ownership cost. Using EPRI`s COMTECH software, investigators performed comprehensive cost analyses for placement of large and small chillers in three representative cities. Case studies of actual installations support these analyses. Electric Chiller Handbook provides a single source of current information on all major issues associated with chiller selection and application. Key issues include chiller availability and markets, rated performance, future viability of various refrigerant options, the cost-effectiveness of alternative chillers, and chilled-water system optimization. The Handbook also describes available hardware, outlines the features and costs of gas-fired competitive systems, and provides methods and comparisons of life-cycle costing of various chiller system options. Analyses of chiller features and economics show that electric chillers are preferable to gas chillers in the large majority of applications, consistent with current market trends. Furthermore, today`s chillers offer a wide range of efficiencies and refrigerant options to serve cooling system needs for the 20-year lifetime of the chiller. Finally, new higher-efficiency models of electric chillers offer very attractive paybacks.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kolo, Daniel
The activities funded by this grant helped educate and inform approximately six thousand individuals who participated in guided tours of the geothermal chiller plant at Johnson Controls Corporate Headquarters in Glendale, Wisconsin over the three year term of the project. In addition to those who took the formal tour, thousands more were exposed to hands-on learning at the self-service video kiosks located in the headquarters building and augmented reality tablet app that allowed for self-guided tours. The tours, video, and app focused on the advantages of geothermal heat pump chillers, including energy savings and environmental impact. The overall tour andmore » collateral also demonstrated the practical application of this technology and how it can be designed into a system that includes many other sustainable technologies without sacrificing comfort or health of building occupants Among tour participants were nearly 1,000 individuals, representing 130 organizations identified as potential purchasers of geothermal heat pump chillers. In addition to these commercial clients, tours were well attended by engineering, facilities, and business trade groups. This has also been a popular tour for groups from Universities around the Midwest and K-12 schools from Wisconsin and Northern Illinois A sequence of operations was put into place to control the chillers and they have been tuned and maintained to optimize the benefit from the geothermal water loop. Data on incoming and outgoing water temperature and flow from the geothermal field was logged and sent to DOE monthly during the grant period to demonstrate energy savings.« less
Design and development of a freezer and chiller delivery box
NASA Astrophysics Data System (ADS)
Zakaria, Mohd Zakimi; Hung, Goh Chung; Dawi, Mohd Syedi Imran Mohd; Hussin, Radhwan; Khalil, Ahmad Nabil Mohd; Naim, Muhammad Khairy Md; Hilmi, Ahmad Humaizi
2017-09-01
This paper presents an action research of designed and fabricated using well insulating materials in order to ensure the coolness inside the freezer and chiller delivery box is as good minimize temperature raised. The main purpose of this study is to develop freeze and chiller delivery box that will be able to keep fresh meat during travelling long delivery. A range of freeze and chill solutions exists for that must be kept within a specific temperature range throughout the supply-and-distribution chain. This will help to minimize the activeness of bacteria to spoil the meats, at the same time it can linger the duration for meats to spoil. All affecting parameter such as temperature inside the delivery box, heat transfer rate, and natural convection flow pattern has been studied to design and development of the delivery box. Finally, temperature distribution analysis has been conducted which showed that in operating condition inside temperature are suitable to keep the fresh meats condition.
40 CFR 1065.376 - Chiller NO2 penetration.
Code of Federal Regulations, 2013 CFR
2013-07-01
... residual water vapor that passed through the chiller at the chiller's outlet temperature and pressure. (3... after major maintenance. (b) Measurement principles. A chiller removes water, which can otherwise interfere with a NOX measurement. However, liquid water remaining in an improperly designed chiller can...
40 CFR 1065.376 - Chiller NO2 penetration.
Code of Federal Regulations, 2011 CFR
2011-07-01
... residual water vapor that passed through the chiller at the chiller's outlet temperature and pressure. (3... after major maintenance. (b) Measurement principles. A chiller removes water, which can otherwise interfere with a NOX measurement. However, liquid water remaining in an improperly designed chiller can...
40 CFR 1065.376 - Chiller NO2 penetration.
Code of Federal Regulations, 2012 CFR
2012-07-01
... residual water vapor that passed through the chiller at the chiller's outlet temperature and pressure. (3... after major maintenance. (b) Measurement principles. A chiller removes water, which can otherwise interfere with a NOX measurement. However, liquid water remaining in an improperly designed chiller can...
Selection and Implementation of Single Building EMCS (Energy Monitoring and Control Systems).
1983-08-01
Setpoint Night Setback 161 Figure 20: Dual Setpoint Night Setback/up 162 Figure 21: Centrifugal Chiller Reset 166 Figure 22: Centrifugal Chiller Capacity...Program outputs. Hot water temperature. Application notes. A dedicated local loop controller may be implemented. Chiller optimization . The chiller ... optimization program can be implemented in chilled water plants with multiple chillers . Based on chiller operating data and the energy input requirements
Enhanced absorption cycle computer model
NASA Astrophysics Data System (ADS)
Grossman, G.; Wilk, M.
1993-09-01
Absorption heat pumps have received renewed and increasing attention in the past two decades. The rising cost of electricity has made the particular features of this heat-powered cycle attractive for both residential and industrial applications. Solar-powered absorption chillers, gas-fired domestic heat pumps, and waste-heat-powered industrial temperature boosters are a few of the applications recently subjected to intensive research and development. The absorption heat pump research community has begun to search for both advanced cycles in various multistage configurations and new working fluid combinations with potential for enhanced performance and reliability. The development of working absorption systems has created a need for reliable and effective system simulations. A computer code has been developed for simulation of absorption systems at steady state in a flexible and modular form, making it possible to investigate various cycle configurations with different working fluids. The code is based on unit subroutines containing the governing equations for the system's components and property subroutines containing thermodynamic properties of the working fluids. The user conveys to the computer an image of his cycle by specifying the different subunits and their interconnections. Based on this information, the program calculates the temperature, flow rate, concentration, pressure, and vapor fraction at each state point in the system, and the heat duty at each unit, from which the coefficient of performance (COP) may be determined. This report describes the code and its operation, including improvements introduced into the present version. Simulation results are described for LiBr-H2O triple-effect cycles, LiCl-H2O solar-powered open absorption cycles, and NH3-H2O single-effect and generator-absorber heat exchange cycles. An appendix contains the user's manual.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-04-01
Commercial chillers are used in space and industrial process cooling. Approximately 3% of commercial buildings, representing 19% of all commercial floor space, are cooled by chillers. Consequently, every chiller represents significant electric (or gas) consumption. Chillers can comprise as much as 30% of a large office building`s electrical load. The selection decisions (electric versus gas, standard versus high efficiency, thermal storage or no thermal storage, etc.) for a new or replacement chiller will affect the customer`s energy consumption for twenty to thirty years. Consequently, this decision can play a major role in the customer`s relationship with the energy provider. However,more » even though these chiller decisions have a significant impact on the utility, today the utility has limited influence over these decisions. EPRI commissioned this study to develop understanding that will help utilities increase their influence over chiller decisions. To achieve this objective, this study looks at the customer`s behavior -- how they make chiller decisions, how the customer`s behavior and decisions are influenced today, and how these decisions might change in the future due to the impact of deregulation and changes in customer goals. The output of this project includes a list of product and service offerings that utilities and EPRI could offer to increase their influence over chiller decisions.« less
40 CFR 1065.376 - Chiller NO2 penetration.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Chiller NO2 penetration. 1065.376... Chiller NO2 penetration. (a) Scope and frequency. If you use a chiller to dry a sample upstream of a NOX measurement instrument, but you don't use an NO2-to-NO converter upstream of the chiller, you must perform...
NASA Astrophysics Data System (ADS)
Liu, Minsheng; Lin, Mark Chingcheng; Wang, Chichuan
2011-12-01
In this study, enhancements of thermal conductivities of ethylene glycol, water, and synthetic engine oil in the presence of copper (Cu), copper oxide (CuO), and multi-walled carbon nanotube (MWNT) are investigated using both physical mixing method (two-step method) and chemical reduction method (one-step method). The chemical reduction method is, however, used only for nanofluid containing Cu nanoparticle in water. The thermal conductivities of the nanofluids are measured by a modified transient hot wire method. Experimental results show that nanofluids with low concentration of Cu, CuO, or carbon nanotube (CNT) have considerably higher thermal conductivity than identical base liquids. For CuO-ethylene glycol suspensions at 5 vol.%, MWNT-ethylene glycol at 1 vol.%, MWNT-water at 1.5 vol.%, and MWNT-synthetic engine oil at 2 vol.%, thermal conductivity is enhanced by 22.4, 12.4, 17, and 30%, respectively. For Cu-water at 0.1 vol.%, thermal conductivity is increased by 23.8%. The thermal conductivity improvement for CuO and CNT nanofluids is approximately linear with the volume fraction. On the other hand, a strong dependence of thermal conductivity on the measured time is observed for Cu-water nanofluid. The system performance of a 10-RT water chiller (air conditioner) subject to MWNT/water nanofluid is experimentally investigated. The system is tested at the standard water chiller rating condition in the range of the flow rate from 60 to 140 L/min. In spite of the static measurement of thermal conductivity of nanofluid shows only 1.3% increase at room temperature relative to the base fluid at volume fraction of 0.001 (0.1 vol.%), it is observed that a 4.2% increase of cooling capacity and a small decrease of power consumption about 0.8% occur for the nanofluid system at a flow rate of 100 L/min. This result clearly indicates that the enhancement of cooling capacity is not just related to thermal conductivity alone. Dynamic effect, such as nanoparticle dispersion may effectively augment the system performance. It is also found that the dynamic dispersion is comparatively effective at lower flow rate regime, e.g., transition or laminar flow and becomes less effective at higher flow rate regime. Test results show that the coefficient of performance of the water chiller is increased by 5.15% relative to that without nanofluid.
2011-01-01
In this study, enhancements of thermal conductivities of ethylene glycol, water, and synthetic engine oil in the presence of copper (Cu), copper oxide (CuO), and multi-walled carbon nanotube (MWNT) are investigated using both physical mixing method (two-step method) and chemical reduction method (one-step method). The chemical reduction method is, however, used only for nanofluid containing Cu nanoparticle in water. The thermal conductivities of the nanofluids are measured by a modified transient hot wire method. Experimental results show that nanofluids with low concentration of Cu, CuO, or carbon nanotube (CNT) have considerably higher thermal conductivity than identical base liquids. For CuO-ethylene glycol suspensions at 5 vol.%, MWNT-ethylene glycol at 1 vol.%, MWNT-water at 1.5 vol.%, and MWNT-synthetic engine oil at 2 vol.%, thermal conductivity is enhanced by 22.4, 12.4, 17, and 30%, respectively. For Cu-water at 0.1 vol.%, thermal conductivity is increased by 23.8%. The thermal conductivity improvement for CuO and CNT nanofluids is approximately linear with the volume fraction. On the other hand, a strong dependence of thermal conductivity on the measured time is observed for Cu-water nanofluid. The system performance of a 10-RT water chiller (air conditioner) subject to MWNT/water nanofluid is experimentally investigated. The system is tested at the standard water chiller rating condition in the range of the flow rate from 60 to 140 L/min. In spite of the static measurement of thermal conductivity of nanofluid shows only 1.3% increase at room temperature relative to the base fluid at volume fraction of 0.001 (0.1 vol.%), it is observed that a 4.2% increase of cooling capacity and a small decrease of power consumption about 0.8% occur for the nanofluid system at a flow rate of 100 L/min. This result clearly indicates that the enhancement of cooling capacity is not just related to thermal conductivity alone. Dynamic effect, such as nanoparticle dispersion may effectively augment the system performance. It is also found that the dynamic dispersion is comparatively effective at lower flow rate regime, e.g., transition or laminar flow and becomes less effective at higher flow rate regime. Test results show that the coefficient of performance of the water chiller is increased by 5.15% relative to that without nanofluid. PMID:21711787
Liu, Minsheng; Lin, Mark Chingcheng; Wang, Chichuan
2011-04-05
In this study, enhancements of thermal conductivities of ethylene glycol, water, and synthetic engine oil in the presence of copper (Cu), copper oxide (CuO), and multi-walled carbon nanotube (MWNT) are investigated using both physical mixing method (two-step method) and chemical reduction method (one-step method). The chemical reduction method is, however, used only for nanofluid containing Cu nanoparticle in water. The thermal conductivities of the nanofluids are measured by a modified transient hot wire method. Experimental results show that nanofluids with low concentration of Cu, CuO, or carbon nanotube (CNT) have considerably higher thermal conductivity than identical base liquids. For CuO-ethylene glycol suspensions at 5 vol.%, MWNT-ethylene glycol at 1 vol.%, MWNT-water at 1.5 vol.%, and MWNT-synthetic engine oil at 2 vol.%, thermal conductivity is enhanced by 22.4, 12.4, 17, and 30%, respectively. For Cu-water at 0.1 vol.%, thermal conductivity is increased by 23.8%. The thermal conductivity improvement for CuO and CNT nanofluids is approximately linear with the volume fraction. On the other hand, a strong dependence of thermal conductivity on the measured time is observed for Cu-water nanofluid. The system performance of a 10-RT water chiller (air conditioner) subject to MWNT/water nanofluid is experimentally investigated. The system is tested at the standard water chiller rating condition in the range of the flow rate from 60 to 140 L/min. In spite of the static measurement of thermal conductivity of nanofluid shows only 1.3% increase at room temperature relative to the base fluid at volume fraction of 0.001 (0.1 vol.%), it is observed that a 4.2% increase of cooling capacity and a small decrease of power consumption about 0.8% occur for the nanofluid system at a flow rate of 100 L/min. This result clearly indicates that the enhancement of cooling capacity is not just related to thermal conductivity alone. Dynamic effect, such as nanoparticle dispersion may effectively augment the system performance. It is also found that the dynamic dispersion is comparatively effective at lower flow rate regime, e.g., transition or laminar flow and becomes less effective at higher flow rate regime. Test results show that the coefficient of performance of the water chiller is increased by 5.15% relative to that without nanofluid.
Standardized EMCS Energy Savings Calculations.
1982-09-01
Reset 56 4.12 Boiler Optimization 57 4.13 Chiller Optimization 58 4.14 Chiller Water Temperature Reset 58 4.15 Condenser Water Temperature.Reset 59...gal, Btu/kwh, etc. (See page 32) 4.13 CHILLER OPTIMIZATION These savings are applicable only to chilled water plants with multiple chillers . The...temperature at end of shutdown period in OF To = hot water temperature setpoint in °F TON = chiller capacity in tons Ts = average temperature of surroundings in
Site-specific investigations on aquifer thermal energy storage for space and process cooling
NASA Astrophysics Data System (ADS)
Brown, D. R.
1991-08-01
The Pacific Northwest Laboratory (PNL) has completed three preliminary site-specific feasibility studies that investigated aquifer thermal energy storage (ATES) for reducing space and process cooling costs. Chilled water stored in an ATES system could be used to meet all or part of the process and/or space cooling loads at the three facilities investigated. Seasonal or diurnal chill ATES systems could be significantly less expensive than a conventional electrically-driven, load-following chiller system at one of the three sites, depending on the cooling water loop return temperature and presumed future electricity escalation rate. For the other two sites investigated, a chill ATES system would be economically competitive with conventional chillers if onsite aquifer characteristics were improved. Well flow rates at one of the sites were adequate, but the expected thermal recovery efficiency was too low. The reverse of this situation was found at the other site, where the thermal recovery efficiency was expected to be adequate, but well flow rates were too low.
Turbocharger chiller modeling and test evaluation. Final report, March-November 1993
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kountz, K.J.; Wurm, J.
1996-07-01
The objectives of this project were: To determine the technoeconomic feasibility of a natural gas-fired turbocharger-based chiller system, arranged in a combined-fluid Rankine/Rankine cycle; To design the turbocharger chiller system for a 50 RT cooling rating point capacity, using available vehicle turbocharges and standard chiller heat exchanger technology; and To evaluate several low, medium, and high pressure refrigerants and refrigerant/lubricant pairs for their thermodynamic and thermal stability characteristics and applicability to the chiller cycle.
Central cooling: compressive chillers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Christian, J.E.
1978-03-01
Representative cost and performance data are provided in a concise, useable form for three types of compressive liquid packaged chillers: reciprocating, centrifugal, and screw. The data are represented in graphical form as well as in empirical equations. Reciprocating chillers are available from 2.5 to 240 tons with full-load COPs ranging from 2.85 to 3.87. Centrifugal chillers are available from 80 to 2,000 tons with full load COPs ranging from 4.1 to 4.9. Field-assemblied centrifugal chillers have been installed with capacities up to 10,000 tons. Screw-type chillers are available from 100 to 750 tons with full load COPs ranging from 3.3more » to 4.5.« less
Study of a two-bed silica gel-water adsorption chiller: performance analysis
NASA Astrophysics Data System (ADS)
Sah, Ramesh P.; Choudhury, Biplab; Das, Ranadip K.
2018-01-01
In this study, a lumped parameter simulation model has been developed for analysis of the thermal performance of a single-stage two-bed adsorption chiller. Since silica gel has low regeneration temperature and water has high latent heat of vaporisation, silica gel-water pair has been chosen as the working pair of the adsorption chiller. Low-grade waste heat or solar heat at around 70-80°C can be used to run this adsorption chiller. In this model, the effects of operating parameters on the performance of the chiller have been studied. The simulated results show that the cooling capacity of the chiller has an optimum value of 5.95 kW for a cycle time of 1600 s with the hot, cooling, and chilled water inlet temperatures at 85°C, 25°C, and 14°C, respectively. The present model can be utilised to investigate and optimise adsorption chillers.
Chiller plant design rules...Have they changed?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eppelheimer, D.
1995-09-01
Chilled water plants are often viewed as energy consumers, actually they are only energy movers. In just the simple process of chilling water, there are four discrete energy moving functions. The chilled water pumps, condenser water pumps, and cooling tower fans are all forms of transport energy. The chiller is a heat pump where energy is consumed to raise the temperature of the heat stream. Insight into improved chiller plant performance can be obtained by tracking the power consumption of these four functions. The performance of centrifugal chillers has improved dramatically in the past 25 years. Certainly some of thismore » improvement is due to technology improvements in heat transfer and compressor efficiency. However, the lion`s share of gain in chiller efficiency is a result of chiller owners budgeting more funds to energy conservation and purchasing more efficient chillers. Since 1970, the efficiency of electric water chillers has improved by nearly 4 percent! The intent of this presentation is to review the energy cost associated with central chilled water plants and identify opportunities in design that may reduce energy costs.« less
NASA Technical Reports Server (NTRS)
Mougin, L. J.
1983-01-01
The best HVAC (heating, ventilating and air conditioning) subsystem to interface with the Engelhard fuel cell system for application in commercial buildings was determined. To accomplish this objective, the effects of several system and site specific parameters on the economic feasibility of fuel cell/HVAC systems were investigated. An energy flow diagram of a fuel cell/HVAC system is shown. The fuel cell system provides electricity for an electric water chiller and for domestic electric needs. Supplemental electricity is purchased from the utility if needed. An excess of electricity generated by the fuel cell system can be sold to the utility. The fuel cell system also provides thermal energy which can be used for absorption cooling, space heating and domestic hot water. Thermal storage can be incorporated into the system. Thermal energy is also provided by an auxiliary boiler if needed to supplement the fuel cell system output. Fuel cell/HVAC systems were analyzed with the TRACE computer program.
21 CFR 173.325 - Acidified sodium chlorite solutions.
Code of Federal Regulations, 2012 CFR
2012-04-01
... a prechiller or chiller tank; (ii) In a prechiller or chiller solution for application to the intact... a prechiller or chiller solution for application to poultry carcass parts; or (v) As a component of... a level sufficient to achieve a solution pH of 2.3 to 2.9. (3) When used in a prechiller or chiller...
Chillers typically cool water, which is then circulated to provide comfort cooling throughout a building or other location. Chillers can be classified by compressor type, including centrifugal, reciprocating, screw, and scroll.
ASHRAE's new Chiller Heat Recovery Application Guide
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dorgan, C.B.; Dorgan, C.E.
2000-07-01
The new Chiller Heat Recovery Application Guide, published by the American Society of Heating, Refrigerating and Air-conditioning Engineers (ASHRAE), provides a comprehensive reference manual on the options available for chiller heat recovery. The information in the guide will assist engineers, owners, and system operators in evaluating the potential of integrating chiller heat recovery into their cooling and heating systems. The primary focus is on new construction and applications where a chiller is being replaced due to inefficiency, high operating and maintenance (O and M) costs, or elimination of refrigerants containing ozone-depleting chemicals known as CFC/HCFCs. While chiller systems for commercialmore » buildings are the primary focus of the guide, the information and procedures also apply to industrial heat pumps. The function of this paper is to highlight key information contained in the guide, including the major benefits of chiller heat recovery, primary candidates, and application procedures. A description of the guide's general format and contents is also provided.« less
Microbiology of broiler carcasses and chemistry of chiller water as affected by water reuse.
Northcutt, J K; Smith, D; Huezo, R I; Ingram, K D
2008-07-01
A study was conducted to determine the effects of treating and reusing poultry chiller water in a commercial poultry processing facility. Broiler carcasses and chiller water were obtained from a commercial processing facility which had recently installed a TOMCO Pathogen Management System to recycle water in sections 2 and 3 of two 3-compartment chillers. In this system, reused water is blended with fresh water to maintain the chiller volume. Carcasses were sampled prechill and postchill (final exit), and chiller water was sampled from the beginning and end of each of the 3 sections. Carcasses were subjected to a whole carcass rinse (WCR) in 0.1% peptone. Numbers of Escherichia coli (EC), coliforms (CF), and Campylobacter (CPY) were determined from the WCR and chiller water samples. Prevalence of Salmonella (SAL) was also determined on the WCR and chiller water samples. On average, prechill levels of bacteria recovered from rinses were 2.6, 2.9, and 2.6 log10 cfu/mL for EC, CF, and CPY, respectively. Ten out of 40 (25%) prechill carcasses were positive for SAL. After chilling, numbers of EC, CF, and CPY recovered from carcass rinses decreased by 1.5, 1.5, and 2.0 log10 cfu/mL, respectively. However, 9 out of 40 (22%) postchill carcasses were positive for SAL. When the chiller water samples were tested, counts of EC, CF, and CPY were found only in water collected from the first section of the chiller (inlet and outlet). Two of 4 water samples collected from the inlet of the first section tested positive for SAL. This study shows that fresh and reused water can be used to cool poultry in chiller systems to achieve a reduction in numbers of bacteria (EC, CF, and CPY) or equivalent prevalence (SAL) of bacteria recovered from broiler carcasses.
Metal glass vacuum tube solar collectors are approaching lower-medium temperature heat application.
Jiang, Xinian
2010-04-26
Solar thermal collectors are widely used worldwide mainly for hot water preparation at a low temperature (less than 80?C). Applications including many industrial processes and central air conditioning with absorption chillers, instead require lower-medium temperature heat (between 90 degrees C and 150 degrees C) to be driven when using solar thermal energy. The metal absorber glass vacuum tube collectors (MGVT) are developed for this type of applications. Current state-of-art and possible future technology development of MGVT are presented.
Solar heating and cooling system installed at Columbus, Ohio
NASA Technical Reports Server (NTRS)
1980-01-01
The Solar Energy System was installed as a part of a new construction of a college building. The building will house classrooms and laboratories, administrative offices and three lecture halls. The Solar Energy System consists of 4,096 square feet (128 panels) Owens/Illinois Evacuated Glass Tube Collector Subsystem, and a 5,000 gallon steel tank below ground storage system. Hot water is circulated between the collectors and storage tank, passing through a water/lithium bromide absorption chiller to cool the building.
Validating the efficacy of peracetic acid mixture as an antimicrobial in poultry chillers.
Bauermeister, Laura J; Bowers, Jordan W J; Townsend, Julie C; McKee, Shelly R
2008-06-01
Peracetic acid mixture (PAHP), which is a combination of peracetic acid and hydrogen peroxide, has been approved as an antimicrobial for use in poultry chillers. To validate its effectiveness, 85 ppm of PAHP was compared with the 30-ppm chlorine treatment in a commercial setting. In this trial, 100 carcasses were sampled for Salmonella and Campylobacter spp. prior to chilling and 100 carcasses were sampled after chilling. In all, 400 carcasses were sampled using 85 ppm of PAHP in the chiller and 400 carcasses were sampled using the chlorine treatment. PAHP at 85 ppm reduced Salmonella-positive carcasses by 92% exiting the chiller, whereas treatment with 30 ppm of chlorine reduced Salmonella by 57%. Additionally, PAHP reduced Campylobacter species-positive carcasses exiting the chiller by 43% while chlorine resulted in a 13% reduction. These results suggest that peracetic acid in combination with hydrogen peroxide may be an effective antimicrobial in poultry chiller applications.
Energy and environmental evaluation of combined cooling heating and power system
NASA Astrophysics Data System (ADS)
Bugaj, Andrzej
2017-11-01
The paper addresses issues involving problems of implementing combined cooling, heating and power (CCHP) system to industrial facility with well-defined demand profiles of cooling, heating and electricity. The application of CCHP system in this particular industrial facility is being evaluated by comparison with the reference system that consists of three conventional methods of energy supply: (a) electricity from external grid, (b) heat from gas-fired boilers and (c) cooling from vapour compression chillers run by electricity from the grid. The CCHP system scenario is based on the combined heat and power (CHP) plant with gas turbine-compressor arrangement and water/lithium bromide absorption chiller of a single-effect type. Those two scenarios are analysed in terms of annual primary energy usage as well as emissions of CO2. The results of the analysis show an extent of primary energy savings of the CCHP system in comparison with the reference system. Furthermore, the environmental impact of the CCHP usage, in the form of greenhouse gases emission reductions, compares quite favourably with the reference conventional option.
NASA Astrophysics Data System (ADS)
Alhamid, M. Idrus; Nasruddin, Aisyah, Nyayu; Sholahudin
2017-03-01
This paper discussed the use of solar thermal collector as an input energy for cooling system. The experimental investigation was undertaken to characterize solar collectors that have been integrated with an absorption chiller. About 62 modules of solar collectors connected in series and parallel are placed on the roof top of MRC building. Thermistors were used to measure the fluid temperature at inlet, inside and outlet of each collector, inside the water tank and ambient temperature. Water flow that circulated from the storage was measured by flow meter, while solar radiation was measured by a pyranometer that was mounted parallel to the collector. Experimental data for a data set was collected in March 2016, during the day time hours of 08:00 - 17:00. This data set was used to calculate solar collector efficiency. The results showed that in the maximum solar radiation, the outlet temperature that can be reached is about 78°C, the utilized energy is about 70 kW and solar collector has an efficiency of 64%. While in the minimum solar radiation, the outlet temperature that can be reached is about 53°C, the utilized energy is about 28 kW and solar collector has an efficiency of 43%.
Performance Analysis of XCPC Powered Solar Cooling Demonstration Project
NASA Astrophysics Data System (ADS)
Widyolar, Bennett K.
A solar thermal cooling system using novel non-tracking External Compound Parabolic Concentrators (XCPC) has been built at the University of California, Merced and operated for two cooling seasons. Its performance in providing power for space cooling has been analyzed. This solar cooling system is comprised of 53.3 m2 of XCPC trough collectors which are used to power a 23 kW double effect (LiBr) absorption chiller. This is the first system that combines both XCPC and absorption chilling technologies. Performance of the system was measured in both sunny and cloudy conditions, with both clean and dirty collectors. It was found that these collectors are well suited at providing thermal power to drive absorption cooling systems and that both the coinciding of available thermal power with cooling demand and the simplicity of the XCPC collectors compared to other solar thermal collectors makes them a highly attractive candidate for cooling projects.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-13
... Conservation Standards for Wine Chillers and Miscellaneous Refrigeration Products: Public Meeting and.... Department of Energy (DOE) is considering establishing energy conservation standards for residential wine... Conservation Standards for Wine Chillers and Miscellaneous Refrigeration Products, and provide docket number...
40 CFR 1065.376 - Chiller NO2 penetration.
Code of Federal Regulations, 2010 CFR
2010-07-01
... CONTROLS ENGINE-TESTING PROCEDURES Calibrations and Verifications Nox and N2o Measurements § 1065.376... measurement instrument, but you don't use an NO2-to-NO converter upstream of the chiller, you must perform... after major maintenance. (b) Measurement principles. A chiller removes water, which can otherwise...
Solar cooling system performance, Frenchman's Reef Hotel, Virgin Islands
NASA Astrophysics Data System (ADS)
Harber, H.
1981-09-01
The operational and thermal performance of a variety of solar systems are described. The Solar Cooling System was installed in a hotel at St. Thomas, U. S. Virgin Islands. The system consists of the evacuated glass tube collectors, two 2500 gallon tanks, pumps, computerized controller, a large solar optimized industrial sized lithium bromide absorption chiller, and associated plumbing. Solar heated water is pumped through the system to the designed public areas such as lobby, lounges, restaurant and hallways. Auxiliary heat is provided by steam and a heat exchanger to supplement the solar heat.
Solar cooling system performance, Frenchman's Reef Hotel, Virgin Islands
NASA Technical Reports Server (NTRS)
Harber, H.
1981-01-01
The operational and thermal performance of a variety of solar systems are described. The Solar Cooling System was installed in a hotel at St. Thomas, U. S. Virgin Islands. The system consists of the evacuated glass tube collectors, two 2500 gallon tanks, pumps, computerized controller, a large solar optimized industrial sized lithium bromide absorption chiller, and associated plumbing. Solar heated water is pumped through the system to the designed public areas such as lobby, lounges, restaurant and hallways. Auxiliary heat is provided by steam and a heat exchanger to supplement the solar heat.
Metal glass vacuum tube solar collectors are approaching lower-medium temperature heat application.
Jiang, Xinian
2010-04-26
Solar thermal collectors are widely used worldwide mainly for hot water preparation at a low temperature (less than 80 degrees C). Applications including many industrial processes and central air conditioning with absorption chillers, instead require lower-medium temperature heat (between 90 degrees C and 150 degrees C) to be driven when using solar thermal energy. The metal absorber glass vacuum tube collectors (MGVT) are developed for this type of applications. Current state-of-art and possible future technology development of MGVT are presented.
Solar heating and cooling system installed at RKL Controls Company, Lumberton, New Jersey
NASA Technical Reports Server (NTRS)
1981-01-01
The final results of the design and operation of a computer controlled solar heated and cooled 40,000 square foot manufacturing building, sales office, and computer control center/display room are summarized. The system description, test data, major problems and resolutions, performance, operation and maintenance manual, equipment manufacturers' literature, and as-built drawings are presented. The solar system is composed of 6,000 square feet of flat plate collectors, external above ground storage subsystem, controls, absorption chiller, heat recovery, and a cooling tower.
Installation-Wide Energy Conservation Demonstration at Fort McClellan, Alabama
1988-11-01
Inefficient Electrical Motors 12 Dispensary Chiller Installation 12 Combustion Optimization of Gas-fired Heating Equipment 12 Infiltration Study of Family... Chiller Installation 34 5 FAMILY HOUSING .................................................... 37 Combustion Optimization of Gas-fired Heating...in Outdoor Air Ventilation 59 Replacement of Inefficient Electric Motors 59 Dispensary Chiller Installation 60 Combustion Optimization of Gas-fired
Chilled water study EEAP program for Walter Reed Army Medical Center. Book 1. Final Submission
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-02-01
The Energy Engineering Analysis Program (EEAP) Study for Walter Reed Army Medical Center (WRAMC) was to provide a thorough examination of the central chilled water plants on site. WRAMC is comprised of seventy-one (71) buildings located on a 113-acre site in Washington, D.C. There are two (2) central chilled water plants (Buildings 48 and 49) each with a primary chilled water distribution system. In addition to the two (2) central plants, three (3) buildings utilize their own independent chillers. Two (2) of the independent chillers (Buildings 7 and T-2), one of which is inoperative (T-2), are smaller air-cooled units, whilemore » the third (Building 54) has a 1,900-ton chilled water plant comprised of three (3) centrifugal chillers. Of the two (2) central chilled water plants, Building 48 houses six (6) chillers totalling 7,080 tons of cooling and Building 49 houses one (1) chiller with 660 tons of cooling. The total chiller cooling capacity available on site is 9,840 tons.« less
Multistage quantum absorption heat pumps.
Correa, Luis A
2014-04-01
It is well known that heat pumps, while being all limited by the same basic thermodynamic laws, may find realization on systems as "small" and "quantum" as a three-level maser. In order to quantitatively assess how the performance of these devices scales with their size, we design generalized N-dimensional ideal heat pumps by merging N-2 elementary three-level stages. We set them to operate in the absorption chiller mode between given hot and cold baths and study their maximum achievable cooling power and the corresponding efficiency as a function of N. While the efficiency at maximum power is roughly size-independent, the power itself slightly increases with the dimension, quickly saturating to a constant. Thus, interestingly, scaling up autonomous quantum heat pumps does not render a significant enhancement beyond the optimal double-stage configuration.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2010-09-01
BEETIT Project: Penn State is designing a freezer that substitutes the use of sound waves and environmentally benign refrigerant for synthetic refrigerants found in conventional freezers. Called a thermoacoustic chiller, the technology is based on the fact that the pressure oscillations in a sound wave result in temperature changes. Areas of higher pressure raise temperatures and areas of low pressure decrease temperatures. By carefully arranging a series of heat exchangers in a sound field, the chiller is able to isolate the hot and cold regions of the sound waves. Penn State’s chiller uses helium gas to replace synthetic refrigerants. Becausemore » helium does not burn, explode or combine with other chemicals, it is an environmentally-friendly alternative to other polluting refrigerants. Penn State is working to apply this technology on a large scale.« less
NASA Astrophysics Data System (ADS)
DiMola, Ashley M.
Buildings account for over 18% of the world's anthropogenic Greenhouse Gas (GHG) emissions. As a result, a technology that can offset GHG emissions associated with buildings has the potential to save over 9 Giga-tons of GHG emissions per year. High temperature fuel cell and absorption chiller (HTFC/AC) technology offers a relatively low-carbon option for meeting cooling and electric loads for buildings while producing almost no criteria pollutants. GHG emissions in the state of California would decrease by 7.48 million metric tons per year if every commercial building in the State used HTFC/AC technology to meet its power and cooling requirements. In order to realize the benefits of HTFC/AC technology on a wide scale, the distributed generation market needs to be exposed to the technology and informed of its economic viability and real-world potential. This work characterizes the economics associated with HTFC/AC technology using select scenarios that are representative of realistic applications. The financial impacts of various input factors are evaluated and the HTFC/AC simulations are compared to the economics of traditional building utilities. It is shown that, in addition to the emissions reductions derived from the systems, HTFC/AC technology is financially preferable in all of the scenarios evaluated. This work also presents the design of a showcase environment, centered on a beta-test application, that presents (1) system operating data gathered using a custom data acquisition module, and (2) HTFC/AC technology in a clear and approachable manner in order to serve the target audience of market stakeholders.
The optimal operation of cooling tower systems with variable-frequency control
NASA Astrophysics Data System (ADS)
Cao, Yong; Huang, Liqing; Cui, Zhiguo; Liu, Jing
2018-02-01
This study investigates the energy performance of chiller and cooling tower systems integrated with variable-frequency control for cooling tower fans and condenser water pumps. With regard to an example chiller system serving an office building, Chiller and cooling towers models were developed to assess how different variable-frequency control methods of cooling towers fans and condenser water pumps influence the trade-off between the chiller power, pump power and fan power under various operating conditions. The matching relationship between the cooling tower fans frequency and condenser water pumps frequency at optimal energy consumption of the system is introduced to achieve optimum system performance.
Comparison of chiller models for use in model-based fault detection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sreedharan, Priya; Haves, Philip
Selecting the model is an important and essential step in model based fault detection and diagnosis (FDD). Factors that are considered in evaluating a model include accuracy, training data requirements, calibration effort, generality, and computational requirements. The objective of this study was to evaluate different modeling approaches for their applicability to model based FDD of vapor compression chillers. Three different models were studied: the Gordon and Ng Universal Chiller model (2nd generation) and a modified version of the ASHRAE Primary Toolkit model, which are both based on first principles, and the DOE-2 chiller model, as implemented in CoolTools{trademark}, which ismore » empirical. The models were compared in terms of their ability to reproduce the observed performance of an older, centrifugal chiller operating in a commercial office building and a newer centrifugal chiller in a laboratory. All three models displayed similar levels of accuracy. Of the first principles models, the Gordon-Ng model has the advantage of being linear in the parameters, which allows more robust parameter estimation methods to be used and facilitates estimation of the uncertainty in the parameter values. The ASHRAE Toolkit Model may have advantages when refrigerant temperature measurements are also available. The DOE-2 model can be expected to have advantages when very limited data are available to calibrate the model, as long as one of the previously identified models in the CoolTools library matches the performance of the chiller in question.« less
Evaluation of chiller modeling approaches and their usability for fault detection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sreedharan, Priya
Selecting the model is an important and essential step in model based fault detection and diagnosis (FDD). Several factors must be considered in model evaluation, including accuracy, training data requirements, calibration effort, generality, and computational requirements. All modeling approaches fall somewhere between pure first-principles models, and empirical models. The objective of this study was to evaluate different modeling approaches for their applicability to model based FDD of vapor compression air conditioning units, which are commonly known as chillers. Three different models were studied: two are based on first-principles and the third is empirical in nature. The first-principles models are themore » Gordon and Ng Universal Chiller model (2nd generation), and a modified version of the ASHRAE Primary Toolkit model, which are both based on first principles. The DOE-2 chiller model as implemented in CoolTools{trademark} was selected for the empirical category. The models were compared in terms of their ability to reproduce the observed performance of an older chiller operating in a commercial building, and a newer chiller in a laboratory. The DOE-2 and Gordon-Ng models were calibrated by linear regression, while a direct-search method was used to calibrate the Toolkit model. The ''CoolTools'' package contains a library of calibrated DOE-2 curves for a variety of different chillers, and was used to calibrate the building chiller to the DOE-2 model. All three models displayed similar levels of accuracy. Of the first principles models, the Gordon-Ng model has the advantage of being linear in the parameters, which allows more robust parameter estimation methods to be used and facilitates estimation of the uncertainty in the parameter values. The ASHRAE Toolkit Model may have advantages when refrigerant temperature measurements are also available. The DOE-2 model can be expected to have advantages when very limited data are available to calibrate the model, as long as one of the previously identified models in the CoolTools library matches the performance of the chiller in question.« less
Marination and Physicochemical Characteristics of Vacuum-aged Duck Breast Meat.
Khan, Muhammad Issa; Lee, Hyun Jung; Kim, Hyun-Joo; Young, Hae In; Lee, Haelim; Jo, Cheorun
2016-11-01
We investigated marinade absorption and physicochemical characteristics of vacuum-aged duck breasts that were halved and individually vacuum-packed for chiller aging at 4°C for 14 d. One half was marinated for 0, 7, or 14 d, while the second half was used as a control. Marinade absorption, cooking loss, cooking yield, texture profile, pH, color, protein solubility, and thiobarbituric acid reactive substances (TBARS) values were evaluated, and protein sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) was performed. Marinade absorption and pH did not vary significantly after 14 d of aging. Marination increased the pH, color (a* and b*) values, and cooking yield and reduced cooking loss. TBARS values significantly increased with aging time, but were significantly reduced by marination. Myofibril and total protein solubility increased with aging and marination, while SDS-PAGE showed protein degradation. Hence, aging and marination can be used simultaneously to improve physicochemical quality and cooking yield of vacuum-aged duck breast.
Energy savings potential in air conditioners and chiller systems
Kaya, Durmus; Alidrisi, Hisham
2014-01-22
In the current paper we quantified and evaluated the energy saving potential in air conditioners and chiller systems. Here, we also showed how to reduce the cost of air conditioners and chiller systems in existing facilities on the basis of payback periods. Among the measures investigated were: (1) installing higher efficiency air conditioners, (2) installing higher efficiency chillers, (3) duty cycling air conditioning units, and (4) utilizing existing economizers on air conditioning units. For each method, examples were provided from Arizona, USA. In these examples, the amount of saved energy, the financial evaluation of this energy, and the investment costmore » and pay back periods were calculated.« less
NASA Technical Reports Server (NTRS)
1980-01-01
The solar energy system installed in the building has 2,978 sq ft of single axis tracking, concentrating collectors and provides solar energy for space heating, space cooling and domestic hot water. A 1,200,000 Btu/hour water tube gas boiler provides hot water for space heating. Space cooling is provided by a 100 ton hot water fired absorption chiller. Domestic hot water heating is provided by a 50 gallon natural gas domestic storage water heater. Extracts from the site files, specification references, drawings, installation, operation and maintenance instructions are included.
Triple effect absorption cycles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Erickson, D.C.; Potnis, S.V.; Tang, J.
1996-12-31
Triple effect absorption chillers can achieve 50% COP improvement over double-effect systems. However, to translate this potential into cost-effective hardware, the most promising embodiments must be identified. In this study, 12 generic triple effect cycles and 76 possible hermetic loop arrangements of those 12 generic cycles were identified. The generic triple effect cycles were screened based on their pressure and solubility field requirements, generic COPs, risk involved in the component design, and number of components in a high corrosive environment. This screening identified four promising arrangements: Alkitrate Topping cycle, Pressure Staged Envelope cycle, High Pressure Overlap cycle, and Dual Loopmore » cycle. All of these arrangements have a very high COP ({approximately} 1.8), however the development risk and cost involved is different for each arrangement. Therefore, the selection of a particular arrangement will depend upon the specific situation under consideration.« less
Creating an automated chiller fault detection and diagnostics tool using a data fault library.
Bailey, Margaret B; Kreider, Jan F
2003-07-01
Reliable, automated detection and diagnosis of abnormal behavior within vapor compression refrigeration cycle (VCRC) equipment is extremely desirable for equipment owners and operators. The specific type of VCRC equipment studied in this paper is a 70-ton helical rotary, air-cooled chiller. The fault detection and diagnostic (FDD) tool developed as part of this research analyzes chiller operating data and detects faults through recognizing trends or patterns existing within the data. The FDD method incorporates a neural network (NN) classifier to infer the current state given a vector of observables. Therefore the FDD method relies upon the availability of normal and fault empirical data for training purposes and therefore a fault library of empirical data is assembled. This paper presents procedures for conducting sophisticated fault experiments on chillers that simulate air-cooled condenser, refrigerant, and oil related faults. The experimental processes described here are not well documented in literature and therefore will provide the interested reader with a useful guide. In addition, the authors provide evidence, based on both thermodynamics and empirical data analysis, that chiller performance is significantly degraded during fault operation. The chiller's performance degradation is successfully detected and classified by the NN FDD classifier as discussed in the paper's final section.
Evaluating best practices for Campylobacter and Salmonella reduction in poultry processing plants.
Wideman, N; Bailey, M; Bilgili, S F; Thippareddi, H; Wang, L; Bratcher, C; Sanchez-Plata, M; Singh, M
2016-02-01
Poultry processing plants in the United States were surveyed on their current Campylobacter and Salmonella control practices. Following surveys, data were collected to develop a baseline for prevalence rates of Salmonella and Campylobacter; then changes in practices were implemented and evaluated for improvements in pathogen control. Surveys were sent to the plant Quality Assurance managers to determine production levels, antimicrobial interventions, and current pathogen testing practices. Initial sampling was performed at 6 plants with similar production volumes, at sites that included carcass samples before any pre-evisceration intervention, after exiting the inside-outside bird washer (IOBW), after exiting the pre-chiller, after exiting the primary chiller, and after exiting any post-chill intervention, as well as a water sample from each scalder, pre-chiller, primary chiller, and post-chill dip tank or finishing chiller. Enumerations and enrichments were performed for Campylobacter and Salmonella. Following the baseline sampling, changes in practices were suggested for each plant and a second sampling was conducted to determine their effectiveness. Results demonstrated that peracetic acid (PAA) was the most effective (P < 0.05) antimicrobial currently in use. The use of a post-chill antimicrobial immersion tank and/or use of a cetylpyridinium chloride (CPC) spray cabinet also displayed a further reduction in microbial levels (P < 0.05) when the primary chiller was not sufficient (P > 0.05). Microbial buildup in the immersion tanks demonstrates the need for effective cleaning, sanitation practices, and chiller maintenance to reduce contamination of poultry with Campylobacter and Salmonella. © 2015 Poultry Science Association Inc.
Control Strategy: Wind Energy Powered Variable Chiller with Thermal Ice Storage
2014-12-01
New York, 2013. [8] A. Togelou et al., “Wind power forecasting in the absence of historical data,” IEEE trans. on sustainable energy, vol. 3, no...WIND ENERGY POWERED VARIABLE CHILLER WITH THERMAL ICE STORAGE by Rex A. Boonyobhas December 2014 Thesis Advisor: Anthony J. Gannon Co...AND DATES COVERED December 20 14 Master ’s Thesis 4. TITLE AND SUBTITLE 5. FUNDING NUMBERS CONTROL STRATEGY: WIND ENERGY POWERED VARIABLE CHILLER
Systems-Level Energy Audit for Main Complex, Construction Engineering Research Laboratory
2003-08-01
gas-fired boilers. Cooling is provided by two York electric chillers housed in the Utilities Building. Electric- ity and gas are metered by...small “instant recovery” electric water heater with a 20-gal size tank. Cooling In the spring of 1993, two R-22 (HCFC) York chiller units (rated at 180...tons each, but which can be peaked at 230 tons under favorable conditions) were in- stalled to replace the old chiller in the Utilities Building
Real-time performance assessment and adaptive control for a water chiller unit in an HVAC system
NASA Astrophysics Data System (ADS)
Bai, Jianbo; Li, Yang; Chen, Jianhao
2018-02-01
The paper proposes an adaptive control method for a water chiller unit in a HVAC system. Based on the minimum variance evaluation, the adaptive control method was used to realize better control of the water chiller unit. To verify the performance of the adaptive control method, the proposed method was compared with an a conventional PID controller, the simulation results showed that adaptive control method had superior control performance to that of the conventional PID controller.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Qian, Mr. Suxin; Gluesenkamp, Kyle R; Hwang, Dr. Yunho
Adsorption chillers are capable of utilizing inexpensive or free low grade thermal energy such as waste heat and concentrated solar thermal energy. Recently developed low regeneration temperature working pairs allow adsorption chillers to be driven by even lower temperature sources such as engine coolant and flat plate solar collectors. In this work, synthetic zeolite/water was implemented into a 3kW adsorption chiller test facility driven by hot water at 70 C. The zeolite was coated onto two fin-and-tube heat exchangers, with heat recovery employed between the two. Cyclic steady state parametric studies were experimentally conducted to evaluate the chiller's performance, resultingmore » in a cooling coefficient of performance (COP) ranging from 0.1 to 0.6 at different operating conditions. Its performance was compared with published values for other low regeneration temperature working pairs. The physical limitations of the synthetic zeolite revealed by parametric study results were then discussed. A novel operating control strategy was proposed based on the unique characteristics of synthetic zeolite. In addition, a physics-based COP prediction model was derived to predict the performance of the chiller under equilibrium loading, and was validated by the experiment results. This analytical expression can be used to estimate the cyclic steady state performance for future studies.« less
The Air Force Did Not Monitor the Energy Savings Performance Contract at Joint Base McGuire
2015-06-29
4: Chiller Plant Upgrade (see Figure 2) • ECM 5: Natural Gas Rate Reduction4 3 ETL 08-5, April 14, 2008; ETL 11-24, July 18, 2011; and ETL 13-13...2009. 6 DOE contract number: DE-AM36-99EE73682. Figure 1. ECM 1 Boiler in Building 2784 Source: DoD OIG Figure 2. ECM 4 Chiller in Building 1908...personnel were unaware of the problem. Furthermore, while reviewing ECM-4, the chiller plant upgrade, we found an additional boiler that contractor
53. Interior of launch support building, brine chiller, view towards ...
53. Interior of launch support building, brine chiller, view towards south - Ellsworth Air Force Base, Delta Flight, Launch Facility, On County Road T512, south of Exit 116 off I-90, Interior, Jackson County, SD
21 CFR 173.375 - Cetylpyridinium chloride.
Code of Federal Regulations, 2014 CFR
2014-04-01
... aqueous solution applied to raw poultry carcasses prior to immersion in a chiller, at a level not to... immersion in a chiller, the treatment will be followed by a potable water rinse of the carcass. [72 FR 67576...
Fault Diagnosis in HVAC Chillers
NASA Technical Reports Server (NTRS)
Choi, Kihoon; Namuru, Setu M.; Azam, Mohammad S.; Luo, Jianhui; Pattipati, Krishna R.; Patterson-Hine, Ann
2005-01-01
Modern buildings are being equipped with increasingly sophisticated power and control systems with substantial capabilities for monitoring and controlling the amenities. Operational problems associated with heating, ventilation, and air-conditioning (HVAC) systems plague many commercial buildings, often the result of degraded equipment, failed sensors, improper installation, poor maintenance, and improperly implemented controls. Most existing HVAC fault-diagnostic schemes are based on analytical models and knowledge bases. These schemes are adequate for generic systems. However, real-world systems significantly differ from the generic ones and necessitate modifications of the models and/or customization of the standard knowledge bases, which can be labor intensive. Data-driven techniques for fault detection and isolation (FDI) have a close relationship with pattern recognition, wherein one seeks to categorize the input-output data into normal or faulty classes. Owing to the simplicity and adaptability, customization of a data-driven FDI approach does not require in-depth knowledge of the HVAC system. It enables the building system operators to improve energy efficiency and maintain the desired comfort level at a reduced cost. In this article, we consider a data-driven approach for FDI of chillers in HVAC systems. To diagnose the faults of interest in the chiller, we employ multiway dynamic principal component analysis (MPCA), multiway partial least squares (MPLS), and support vector machines (SVMs). The simulation of a chiller under various fault conditions is conducted using a standard chiller simulator from the American Society of Heating, Refrigerating, and Air-conditioning Engineers (ASHRAE). We validated our FDI scheme using experimental data obtained from different types of chiller faults.
Chilled water study EEAP program for Walter Reed Army Medical Center: Book 2. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-02-01
The Energy Engineering Analysis Program (EEAP) Study for Walter Reed Army Medical Center (WRAMC) was to provide a thorough examination of the central chilled water plants on site. WRAMC is comprised of seventy-one (71) buildings located on a 113-acre site in Washington, D.C. There are two (2) central chilled water plants (Buildings 48 and 49) each with a primary chilled water distribution system. In addition to the two (2) central plants, three (3) buildings utilize their own independent chillers. Two (2) of the independent chillers (Buildings 7 and T-2), one of which is inoperative (T-2), are smaller air-cooled units, whilemore » the third (Building 54) has a 1,900-ton chilled water plant comprised of three (3) centrifugal chillers. Of the two (2) central chilled water plants, Building 48 houses six (6) chillers totalling 7,080 tons of cooling and Building 49 houses one (1) chiller with 660 tons of cooling. The total chiller cooling capacity available on site is 9,840 tons. The chilled water systems were reviewed for alternative ways of conserving energy on site and reducing the peak-cooling load. Distribution systems were reviewed to determine which buildings were served by each of the chilled water plants and to determine chilled water usage on site. Evaluations were made of building exterior and interior composition in order to estimate cooling loads. Interviews with site personnel helped Entech better understand the chilled water plants, the distribution systems, and how each system was utilized.« less
19. INTERIOR, 'CHILLER NO. 2' (G.S.A. PHOTOCOPY, N.D.) (4 x ...
19. INTERIOR, 'CHILLER NO. 2' (G.S.A. PHOTOCOPY, N.D.) (4 x 5 NEGATIVE) - U.S. General Services Administration, Central Heating Plant, C & D Streets between Twelfth & Thirteenth Streets Southwest, Washington, District of Columbia, DC
40 CFR 1065.272 - Nondispersive ultraviolet analyzer.
Code of Federal Regulations, 2014 CFR
2014-07-01
... configurations: (1) Connect an NDUV downstream of any dryer or chiller that is downstream of an NO2-to-NO... chiller that meets the verification in § 1065.376. [70 FR 40516, July 13, 2005, as amended at 73 FR 59323...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Jian; Zheng, Jian; Barpaga, Dushyant
A mixed metal strategy, in which two different metal nodes coexist in one MOF framework, was examined using MOF-74. The Ni salt precursor for the MOF-74(Ni) analogue was partially replaced during synthesis with relatively inexpensive Zn salt. These bimetallic MOFs were developed and examined for water sorption for potential use in adsorption cooling/chiller applications. Varying concentration ratios of Ni:Zn in MOF-74 achieved using this mixed metal strategy were shown to provide unique impacts on H2O uptake while significantly mitigating the costs of synthesis
Preliminary design of a supercritical CO2 wind tunnel
NASA Astrophysics Data System (ADS)
Re, B.; Rurale, A.; Spinelli, A.; Guardone, A.
2017-03-01
The preliminary design of a test-rig for non-ideal compressible-fluid flows of carbon dioxide is presented. The test-rig is conceived to investigate supersonic flows that are relevant to the study of non-ideal compressible-fluid flows in the close proximity of the critical point and of the liquid-vapor saturation curve, to the investigation of drop nucleation in compressors operating with supercritical carbon dioxide and and to the study of flow conditions similar to those encountered in turbines for Organic Rankine Cycle applications. Three different configurations are presented and examined: a batch-operating test-rig, a closed-loop Brayton cycle and a closed-loop Rankine cycle. The latter is preferred for its versatility and for economic reasons. A preliminary design of the main components is reported, including the heat exchangers, the chiller, the pumps and the test section.
22. DETAIL OF CHILLERS 1 AND 2 (MST AIRCONDITIONING SYSTEM) ...
22. DETAIL OF CHILLERS 1 AND 2 (MST AIR-CONDITIONING SYSTEM) INTERIOR, NORTHEAST CORNER, STATION 30, SLC-3W MST - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA
Code of Federal Regulations, 2013 CFR
2013-01-01
... Refrigerated Volume and Total Shelf Area of Household Refrigerators and Household Wine Chillers,” and sections... Chillers and Freezers.” [70 FR 60414, Oct. 18, 2005, as amended at 77 FR 10318, Feb. 21, 2012] Energy...
Code of Federal Regulations, 2014 CFR
2014-01-01
... Refrigerated Volume and Total Shelf Area of Household Refrigerators and Household Wine Chillers,” and sections... Chillers and Freezers.” [70 FR 60414, Oct. 18, 2005, as amended at 77 FR 10318, Feb. 21, 2012] Energy...
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1991-03-01
This document constitutes the Pre-Final Submittal for Contract DACA21-84-C-0603, Energy Audits of Boiler/Chiller Plants, Ft. Bragg, North Carolina. The purpose of this report is to indicate the work accomplished to date, show samples of field data collected, illustrate the methods and justifications of the approaches taken, outline the present conditions, and make recommendations for the potential energy efficiency improvements to the central energy plants of Fort Bragg. The specific buildings analyzed are: (1) Building C-1432 82nd Heating Plant; (2) Building D-3529 JFK Heating Cooling Plant, and (3) Building C-6039 82nd Chiller Plant. The following buildings were part of the originalmore » scope of work, but were deleted for reasons explained further in Section 1.0 of this report: (1) Building C-7549 Standby Plant for C-1432; (2) Building N-6002 New EM Barracks Complex; and (3) Building H-6240 `H` Area Chiller Plant.« less
34. SITE BUILDING 002 SCANNER BUILDING ROOM 105 ...
34. SITE BUILDING 002 - SCANNER BUILDING - ROOM 105 - CHILLER ROOM, SHOWING SINGLE COMPRESSOR, LIQUID CHILLERS AND "CHILLED WATER RETURN", COOLING TOWER 'TOWER WATER RETURN" AND 'TOWER WATER SUPPLY" LINES. - Cape Cod Air Station, Technical Facility-Scanner Building & Power Plant, Massachusetts Military Reservation, Sandwich, Barnstable County, MA
Eglezos, Sofroni; Dykes, Gary A; Huang, Bixing; Turner, Mark S; Seale, Richard
2013-08-01
Possible selection for and establishment of stress-resistant Listeria monocytogenes variants as a consequence of heating interventions is of concern to the food industry. Lineage analysis and multilocus variable number tandem repeat analysis (MLVA) was performed on 20 L. monocytogenes isolates, of which 15 were obtained before and 5 were obtained after heat treatment of a postcook meat chiller. The ctsR gene (a class III heat shock gene regulator) from 14 isolates was amplified and sequenced because previous work has indicated that spontaneous mutations can occur in this gene during heat treatment. Heat treatment of the meat chiller did not significantly change the relative abundance of the various L. monocytogenes lineages; lineage II strains (less-heat-resistant isolates) dominated both before and after heat treatment. MLVA typing confirmed that some isolates of L. monocytogenes occur both before and after heat treatment of the chiller. No isolate of L. monocytogenes indicated any likely functionally significant mutations in ctsR. This study indicates the absence of any obvious difference in the profiles of L. monocytogenes strains obtained before and after heat treatment of a meat chiller, based on the characteristics examined. Although this finding supports the effectiveness of heat treatment, the limited number of strains used and characteristics examined mean that further study on a larger scale is required before firm conclusions can be drawn.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-22
... collectors for solar thermal systems (when used in an educational context for the purposes of comparing relative efficiency of solar thermal technologies); (3) 2-ton adsorption chillers (for educational purposes... thermal technologies); (3) 2- ton adsorption chillers (for educational purposes, or where alternative...
Variable-Speed Screw Chiller, Sidney Yates Building, Washington, DC
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ostrouchov, George; Adams, Mark B.; Howett, Daniel H.
2017-07-01
This report captures the findings from an evaluation ORNL performed on a new chiller technology as part of GSA's Proving Ground Program. Note: Appendices B&C were removed from this report while the author looks for a way to insert them without consuming over 200MB of file size.
Simulation of adsorber tube diameter's effect on new design silica gel-water adsorption chiller
NASA Astrophysics Data System (ADS)
Nasruddin, Taufan, A.; Manga, A.; Budiman, D.
2017-03-01
A new design of silica gel-water adsorption chiller is proposed. The design configuration is composed of two sorption chambers with compact fin tube heat exchangers as adsorber, condenser, and evaporator. Heat and mass recovery were adopted in order to increase the cooling capacity. Numerical modelling and calculation were used to show the performance of the chiller with different adsorber tube diameter. Under typical condition for hot water inlet/cooling water inlet/chilled water outlet temperatures are 90/30/7°C, respectively, the simulation results showed the best average value of COP, SCP, and cooling power are 0.19, 15.88 W/kg and 279.89 W using 3/8 inch tube.
IDENTIFYING AND EVALUATING ALTERNATIVES TO CFC-114 FOR NAVY SHIPBOARD CHILLERS
The paper outlines EPA's role in investigating alternatives to replace the chlorofluorocarbon CFC-114 (1,1,2,2-tetrafluorodichloroethane) as the refrigerant in retrofitted Navy shipboard chillers. The isomers HFC-236ea (1,1,1,2,3,3-hexafluoropropane) and HFC-236fa (1,1,1,3,3,3-he...
19. Perimeter acquisition radar building room #105, sign reads: Three ...
19. Perimeter acquisition radar building room #105, sign reads: Three 660-ton trane chillers, each chiller can supply enough cooling for approximately 250 average air-conditioned homes - Stanley R. Mickelsen Safeguard Complex, Perimeter Acquisition Radar Building, Limited Access Area, between Limited Access Patrol Road & Service Road A, Nekoma, Cavalier County, ND
Sinclair Stockpiles CFCs for Future Use.
ERIC Educational Resources Information Center
George, Stephen C.
1996-01-01
A Dayton (Ohio) community college's 21 buildings were cooled by a network of 5 chillers, all of which used soon-to-be-banned chlorofluorocarbons (CFCs). A reclamation program provides the college with reusable refrigerant and eliminates chiller replacement costs. Refrigerant from three of the old units is stockpiled for use in the two other…
Development of an energy storage tank model
NASA Astrophysics Data System (ADS)
Buckley, Robert Christopher
A linearized, one-dimensional finite difference model employing an implicit finite difference method for energy storage tanks is developed, programmed with MATLAB, and demonstrated for different applications. A set of nodal energy equations is developed by considering the energy interactions on a small control volume. The general method of solving these equations is described as are other features of the simulation program. Two modeling applications are presented: the first using a hot water storage tank with a solar collector and an absorption chiller to cool a building in the summer, the second using a molten salt storage system with a solar collector and steam power plant to generate electricity. Recommendations for further study as well as all of the source code generated in the project are also provided.
Smith, D P; Cason, J A; Berrang, M E
2005-07-01
The effect of prechill fecal contamination on numbers of bacteria on immersion-chilled carcasses was tested in each of three replicate trials. For each trial, 16 eviscerated broiler carcasses were split into 32 halves and assigned to one of two groups. Cecal contents (0.1 g inoculated with Campylobacter and nalidixic acid-resistant Salmonella) were applied to each of eight halves in one group (direct contamination) that were placed into one paddle chiller (contaminated), whereas the other paired halves were placed into another chiller (control). From the second group of eight split birds, one of each paired half was placed in the contaminated chiller (to determine cross-contamination) and the other half was placed in the control chiller. Postchill carcass halves were sampled by a 1-min rinse in sterile water, which was collected and cultured. Bacterial counts were reported as log CFU per milliliter of rinsate. There were no significant statistical differences (paired t test, P < 0.05) from direct contamination for coliforms (mean 3.0 log CFU) and Escherichia coli (mean 2.7 log CFU), although Campylobacter numbers significantly increased from control values because of direct contamination (1.5 versus 2.1 log CFU), and the incidence increased from 79 to 100%. There was no significant effect of cross-contamination on coliform (mean 2.9 log CFU) or E. coli (mean 2.6 log CFU) numbers. Nevertheless, Campylobacter levels were significantly higher after exposure to cross-contamination (1.6 versus 2.0 log CFU), and the incidence of this bacterium increased from 75 to 100%. Salmonella-positive halves increased from 0 to 42% postchill because of direct contamination and from 0 to 25% as a result of cross-contamination after chilling. Water samples and surface swabs taken postchill from the contaminated chiller were higher for Campylobacter than those taken from the control chiller. Immersion chilling equilibrated bacterial numbers between contaminated and control halves subjected to either direct contamination or cross-contamination for coliforms and E. coli. Campylobacter numbers, Campylobacter incidence, and Salmonella incidence increased because of both direct contamination and cross-contamination in the chiller. Postchill E. coli numbers did not indicate which carcass halves were contaminated with feces before chilling.
Waste heat recovery options in a large gas-turbine combined power plant
NASA Astrophysics Data System (ADS)
Upathumchard, Ularee
This study focuses on power plant heat loss and how to utilize the waste heat in energy recovery systems in order to increase the overall power plant efficiency. The case study of this research is a 700-MW natural gas combined cycle power plant, located in a suburban area of Thailand. An analysis of the heat loss of the combustion process, power generation process, lubrication system, and cooling system has been conducted to evaluate waste heat recovery options. The design of the waste heat recovery options depends to the amount of heat loss from each system and its temperature. Feasible waste heat sources are combustion turbine (CT) room ventilation air and lubrication oil return from the power plant. The following options are being considered in this research: absorption chillers for cooling with working fluids Ammonia-Water and Water-Lithium Bromide (in comparison) and Organic Rankine Cycle (ORC) with working fluids R134a and R245fa. The absorption cycles are modeled in three different stages; single-effect, double-effect and half-effect. ORC models used are simple ORC as a baseline, ORC with internal regenerator, ORC two-phase flash expansion ORC and ORC with multiple heat sources. Thermodynamic models are generated and each system is simulated using Engineering Equation Solver (EES) to define the most suitable waste heat recovery options for the power plant. The result will be synthesized and evaluated with respect to exergy utilization efficiency referred as the Second Law effectiveness and net output capacity. Results of the models give recommendation to install a baseline ORC of R134a and a double-effect water-lithium bromide absorption chiller, driven by ventilation air from combustion turbine compartment. The two technologies yield reasonable economic payback periods of 4.6 years and 0.7 years, respectively. The fact that this selected power plant is in its early stage of operation allows both models to economically and effectively perform waste heat recovery during the power plant's life span. Furthermore, the recommendation from this research will be submitted to the Electricity Generating Authority of Thailand (EGAT) for implementation. This study will also be used as an example for other power plants in Thailand to consider waste energy utilization to improve plant efficiency and sustain fuel resources in the future.
1985-02-01
Deck - Cold Deck Reset Reheat Coil Reset Steam Boiler Optimization [lot Water Outside Air Reset Chiller Optimization Chiller Water Temperature Reset...with programming techniques for each type of installed DDC in order to effect changes in operating setpoints and application programs. *Communication...can be changed without recailbration of instrumentation devices. Changes to the application software, operating setpoints and parameters require the
USDA-ARS?s Scientific Manuscript database
In poultry processing plants, chicken carcasses were processed through a succession of steps including their immersion in scalder and chiller water tanks. Water tank microbiota may impact the microbiological quality of carcasses and the occurrence of pathogens or spoilage bacteria may lead to their ...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-08
... use for such products, (e.g., thermoelectric wine chillers) is likely to exceed the 100 kilowatt-hour.... DOE's analysis describes both the burdens and benefits of potential standards, pursuant to 42 U.S.C... efforts to amend the standards for these products, interested parties urged DOE to include wine chillers...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gayeski, N.; Armstrong, Peter; Alvira, M.
2011-11-30
KGS Buildings LLC (KGS) and Pacific Northwest National Laboratory (PNNL) have developed a simplified control algorithm and prototype low-lift chiller controller suitable for model-predictive control in a demonstration project of low-lift cooling. Low-lift cooling is a highly efficient cooling strategy conceived to enable low or net-zero energy buildings. A low-lift cooling system consists of a high efficiency low-lift chiller, radiant cooling, thermal storage, and model-predictive control to pre-cool thermal storage overnight on an optimal cooling rate trajectory. We call the properly integrated and controlled combination of these elements a low-lift cooling system (LLCS). This document is the final report formore » that project.« less
2013-12-01
capacities ranging from 3-330 tons using silica gel or 250-450 tons using zeolite desiccant. Adsorption chillers are also currently manufactured by...Mayekawa (20-100 tons using zeolite desiccant) • Union (10-125 tons using silica gel) Sortech - 2 ton units for residential use • InvenSor - 3 ton
DOE Office of Scientific and Technical Information (OSTI.GOV)
Armstrong, Peter; Jiang, Wei; Winiarski, David W.
2009-03-31
this paper develops component and subsystem models used to evaluat4e the performance of a low-lift cooling system with an air-colled chiller optimized for variable-speed and low-pressure-ratio operation, a hydronic radient distribution system, variable-speed transport miotor controls, and peak-shifting controls.
Simulation and Experimental Study of Metal Organic Frameworks Used in Adsorption Cooling
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jenks, Jeromy J.; Motkuri, Radha K.; TeGrotenhuis, Ward
2016-10-11
Metal-organic frameworks (MOFs) have recently attracted enormous interest over the past few years in energy storage and gas separation, yet there have been few reports for adsorption cooling applications. Adsorption cooling technology is an established alternative to mechanical vapor compression refrigeration systems and is an excellent alternative in industrial environments where waste heat is available. We explored the use of MOFs that have very high mass loading and relatively low heats of adsorption, with certain combinations of refrigerants to demonstrate a new type of highly efficient adsorption chiller. Computational fluid dynamics combined with a system level lumped-parameter model have beenmore » used to project size and performance for chillers with a cooling capacity ranging from a few kW to several thousand kW. These systems rely on stacked micro/mini-scale architectures to enhance heat and mass transfer. Recent computational studies of an adsorption chiller based on MOFs suggests that a thermally-driven coefficient of performance greater than one may be possible, which would represent a fundamental breakthrough in performance of adsorption chiller technology. Presented herein are computational and experimental results for hydrophyilic and fluorophilic MOFs.« less
NASA Astrophysics Data System (ADS)
Wijaya Sunu, Putu; Made Rasta, I.; Anakottapary, Daud Simon; Made Suarta, I.; Cipta Santosa, I. D. M.
2018-01-01
The aims of this study to compares the performance characteristics of a water chiller air conditioning simulation equipped with thermostatic expansion valve (TEV) with those of a capillary tube. Water chiller system filled with the same charge of refrigerant. Comparative analyses were performed based on coefficient of performance (COP) and performance parameter of the refrigeration system, carried out at medium cooling load level with the ambient temperature of 29-31°C, constant compressor speed and fixed chilled water volume flowrate at 15 lpm. It was shown that the TEV system showed better energy consumption compared to that of capillary tube. From the coefficient of performance perspective, the thermostatic expansion valve system showed higher COP (± 21.4%) compared to that of capillary tube system.
NASA Astrophysics Data System (ADS)
Yoshikawa, Choiku; Hattori, Kazuhiro; Jeong, Jongsoo; Saito, Kiyoshi; Kawai, Sunao
An ejector can transform the expansion energy of the driving flow into the pressure build-up energy of the suction flow. Therefore, by utilizing the ejector instead of the expansion valve for the vapor compression cycle, the performance of the cycle can be greatly improved. Until now, the performance of the vapor compression cycle with the ejector has not been examined sufficiently. Therefore, this paper constructs the simulation model of the vapor compression cycle with the ejector and investigates the performance of that cycle by the simulation. Working fluids are ammonia and CO2. As a result, in case of the ejector efficiency 90%, COP of the vapor compression cycle using ammonia with the ejector is 5% higher than that of the conventional cycle and COP using CO2 with the ejector is 22% higher than that of the conventional cycle.
NASA Astrophysics Data System (ADS)
Wijaya Sunu, Putu; Anakottapary, Daud Simon; Mulawarman, A. A. N. B.; Cipta Santosa, I. D. M.; Putu Sastra Negara, I.
2018-01-01
In this paper, the volume flowrate of chilled water in the water chiller simulation apparatus was optimized using experimental studied. The experimental analysis was performed on the fan coil unit (FCU) of the system. The chilled water flows in tube side and the air as a hot fluid flows throughout the tube and fin of FCU. The thermal performance and analysis of the heat transfer is examined using various chilled water flowrate e.g. 11, 12, 13, 14, 15 lpm. The effect of the flowrate to the important parameter such as LMTD temperature, heat absorb used for investigate the heat transfer characteristics. The result showed that the heat transfer characteristics has been increased with the increased of chilled water volume flowrate.
1983-03-01
economizer and enthalpy cycles, scheduled temperature reset, chiller control and chilled water reset, boiler control and hot water temperature reset...temperature reset, chiller control and chilled water reset, boiler control and hot water temperature reset, and condenser water temperature reset. Recent...day-night setback. Day-night setback is the strategy of reducing the heating space temperature setpoint or raising the cooling space temperature
Design and Analysis of a Two-Stage Adsorption Air Chiller
NASA Astrophysics Data System (ADS)
Benrajesh, P.; Rajan, A. John
2017-05-01
The objective of this article is to design and build a bio-friendly air-conditioner, by using adsorption method in the presence of 15% of calcium carbide in water. Aluminum sheet metals are used to form three identical tunnels, to pass the air for processing. Exhaust heat generated from the dairy sterilizing unit process is reutilized, for cooling the environment through this equipment. This equipment is designed, and the analysis is carried out to quantify the COP, SCP, and cooling power. Heat exchangers are designed; its Performance Parameters are quantified and correlated with the conventional designs. It is observed that the new adsorption chiller can produce the coefficient of performance of chiller as 1.068; the Specific cooling power of 10.66 (W/Kg); and the Cooling power of 4.2 KW. This equipment needs 0 to 15 minutes to reach the desired cool breeze (24°c) from the existing room temperature (29°c).
NASA Technical Reports Server (NTRS)
1980-01-01
The building has approximately 5600 square feet of conditioned space. Solar energy was used for space heating, space cooling, and preheating domestic hot water (DHW). The solar energy system had an array of evacuated tube-type collectors with an area of 1068 square feet. A 50/50 solution of ethylene glycol and water was the transfer medium that delivered solar energy to a tube-in-shell heat exchanger that in turn delivered solar heated water to a 1100 gallon pressurized hot water storage tank. When solar energy was insufficient to satisfy the space heating and/or cooling demand, a natural gas-fired boiler provided auxiliary energy to the fan coil loops and/or the absorption chillers. Extracts from the site files, specification references, drawings, and installation, operation and maintenance instructions are presented.
System effects of primary energy reduction connected with operation of the CHP plants
NASA Astrophysics Data System (ADS)
Ziębik, Andrzej; Gładysz, Paweł
2017-06-01
The paper is devoted to explication of one of the advantages of heat and electricity cogeneration, rarely considered in technical literature. Usually attention is paid to the fact that heat losses of the heat distribution network are less severe in the case of cogeneration of heat in comparison with its separate production. But this conclusion is also true in other cases when the internal consumption of heat is significant. In this paper it has been proved in the case of two examples concerning trigeneration technology with an absorption chiller cooperating with a combined heat and power (CHP) plant and CHP plant integrated with amine post-combustion CO2 processing unit. In both considered cases it might be said that thanks to cogeneration we have to do with less severe consequences of significant demand of heat for internal purposes.
1982-06-01
start/stop chiller optimization , and demand limiting were added. The system monitors a 7,000 ton chiller plant and controls 74 air handlers. The EMCS does...Modify analog limits. g. Adjust setpoints of selected controllers. h. Select manual or automatic control modes. i. Enable and disable individual points...or event schedules and controller setpoints ; make nonscheduled starts and stops of equipment or disable field panels when required for routine
Using the adsorption chillers for waste heat utilisation from the CCS installation
NASA Astrophysics Data System (ADS)
Sztekler, Karol; Kalawa, Wojciech; Nowak, Wojciech; Stefański, Sebastian; Krzywański, Jarosław; Grabowska, Karolina
2018-06-01
Worldwide tendencies in the scope of environmental protection demonstrate the requirement for the limited carbon dioxide emission, that influences on the development of greenhouse effect. As a result of coal as a basic fuel used in the professional power industry, this industry sector is the greatest CO2 polluter and it means that works on the reduction of carbon dioxide in such industry are completely justified. In the IPSEpro programming environment, a reference block model for a conventional coal power station was elaborated, including the CO2 separation unit basing on the adsorption methods with the CO2 preparation installation to liquid state. Simulation researches were conducted with means of numeric techniques, that enabled the system analysis for the CO2 separation unit with the CO2 preparation system to the liquid state, as well as analysis was made for the use of chiller systems, basing on the adsorption technology for waste heat use originating from the compression of CO2 in a cascade system, as well as for potential opportunities for further exploitation of the produced chilled water in the CCS cycle. We analysed in these papers the opportunities for chiller systems application, based on the adsorption chillers in the CCS installation used for the reduction of CO2 emission in the coal power station and its influence on the operation of a power station cycle.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Conklin, Shane
2013-09-30
Shell space fit out included faculty office advising space, student study space, staff restroom and lobby cafe. Electrical, HVAC and fire alarm installations and upgrades to existing systems were required to support the newly configured spaces. These installations and upgrades included audio/visual equipment, additional electrical outlets and connections to emergency generators. The project provided increased chilled water capacity with the addition of an electric centrifugal chiller. Upgrades associated with chiller included upgrade of exhaust ventilation fan, electrical conductor and breaker upgrades, piping and upgrades to air handling equipment.
1989-05-01
Typical ranges are from 50 to 70 OF. If a chiller is dedicated to serving water-cooled electronic equipment, the chilled water temperature setpoint can...can be satisfied with 50 OF chilled water. The COP of the dedicated chiller is improved by raising the chilled water setpoint , and the total life-cycle...USACERL TECHNICAL REPORT E-89/10 May 1989 Studies in Optimizing HVAC Hardware for C31 Facilities US Army Corps of Engineers Construction Engineering
NASA Astrophysics Data System (ADS)
Choudhury, Biplab; Chatterjee, Pradip Kumar; Habib, Khairul; Saha, Bidyut Baran
2018-06-01
The demand for cooling, especially in the developing economies, is rising at a fast rate. Fast-depleting sources of fossil fuel and environmental concerns necessitate looking for alternative cooling solutions. Solar heat driven adsorption based cooling cycles are environmentally friendly due to their use of natural refrigerants and the thermal compression process. In this paper, a performance simulation study of a basic two-bed solar adsorption chiller has been performed through a transient model for two different climatic locations in India. Effect of operating temperatures and cycle time on the chiller performance has been studied. It is observed that the solar hot water temperature obtained in the composite climate of Delhi (28.65°N, 77.25°E) can run the basic adsorption cooling cycle efficiently throughout the year. Whereas, the monsoon months of July and August in the warm and humid climate of Durgapur (23.48°N, 87.32°E) are unable to supply the required driving heat.
NASA Astrophysics Data System (ADS)
Hongqi, Jing; Li, Zhong; Yuxi, Ni; Junjie, Zhang; Suping, Liu; Xiaoyu, Ma
2015-10-01
A novel high-efficiency cooling mini-channel heat-sink structure has been designed to meet the package technology demands of high power density laser diode array stacks. Thermal and water flowing characteristics have been simulated using the Ansys-Fluent software. Owing to the increased effective cooling area, this mini-channel heat-sink structure has a better cooling effect when compared with the traditional macro-channel heat-sinks. Owing to the lower flow velocity in this novel high efficient cooling structure, the chillers' water-pressure requirement is reduced. Meanwhile, the machining process of this high-efficiency cooling mini-channel heat-sink structure is simple and the cost is relatively low, it also has advantages in terms of high durability and long lifetime. This heat-sink is an ideal choice for the package of high power density laser diode array stacks. Project supported by the Defense Industrial Technology Development Program (No. B1320133033).
Energy conservation and solar retrofit analysis of a large office building
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arasteh, D.; Hepner, M.
1981-01-01
During the winter and spring of 1981, a technical energy conservation and solar analysis of the JFK Federal Office Building in Boston was conducted. To reduce the building's energy consumption of a total of nineteen Energy Conservation Measures (ECM's) were analyzed. Among the measures studied were: reduction of ventilation and supply air, central automation controls, programmable lighting, absorption chiller replacement, fenestration modification and heat recovery. The results of the analyse show that implementation of all recommended ECM's would reduce energy consumption by 50% from a raw source Annual Energy Index (AEI) of 33.9 x 10/sup 8/ J/m/sup 2/ (299 MBtu/sf)more » to 17.2 10/sup 8/ j/m/sup 2/ (152 MBtu/sf). This relates to a savings of approximately $950,000 annually at April 1981 energy costs for a total construction cost of three million dollars.« less
Solar heating, cooling, and hot water systems installed at Richland, Washington
NASA Technical Reports Server (NTRS)
1979-01-01
The project described is part of the U. S. Department of Energy's solar demonstration program, and became operational in April 1978. The solar system uses 6,000 square feet of flat-plate liquid collectors in a closed loop to deliver solar energy through a liquid-liquid heat exchanger to the building heat-pump duct work or 9,000-gallon thermal energy storage tank. A 25-ton Arkla solar-driven absorption chiller provides the cooling, in conjunction with a 2,000 gallon chilled water storage tank and reflective ponds on three sides of the building surplus heat. A near-by building is essentially identical except for having conventional heat-pump heating and cooling, and can serve as an experimental control. An on-going public relations program was provided from the beginning of the program, and resulted in numerous visitors and tour groups.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Auslander, David; Culler, David; Wright, Paul
The goal of the 2.5 year Distributed Intelligent Automated Demand Response (DIADR) project was to reduce peak electricity load of Sutardja Dai Hall at UC Berkeley by 30% while maintaining a healthy, comfortable, and productive environment for the occupants. We sought to bring together both central and distributed control to provide “deep” demand response1 at the appliance level of the building as well as typical lighting and HVAC applications. This project brought together Siemens Corporate Research and Siemens Building Technology (the building has a Siemens Apogee Building Automation System (BAS)), Lawrence Berkeley National Laboratory (leveraging their Open Automated Demand Responsemore » (openADR), Auto-Demand Response, and building modeling expertise), and UC Berkeley (related demand response research including distributed wireless control, and grid-to-building gateway development). Sutardja Dai Hall houses the Center for Information Technology Research in the Interest of Society (CITRIS), which fosters collaboration among industry and faculty and students of four UC campuses (Berkeley, Davis, Merced, and Santa Cruz). The 141,000 square foot building, occupied in 2009, includes typical office spaces and a nanofabrication laboratory. Heating is provided by a district heating system (steam from campus as a byproduct of the campus cogeneration plant); cooling is provided by one of two chillers: a more typical electric centrifugal compressor chiller designed for the cool months (Nov- March) and a steam absorption chiller for use in the warm months (April-October). Lighting in the open office areas is provided by direct-indirect luminaries with Building Management System-based scheduling for open areas, and occupancy sensors for private office areas. For the purposes of this project, we focused on the office portion of the building. Annual energy consumption is approximately 8053 MWh; the office portion is estimated as 1924 MWh. The maximum peak load during the study period was 1175 kW. Several new tools facilitated this work, such as the Smart Energy Box, the distributed load controller or Energy Information Gateway, the web-based DR controller (dubbed the Central Load-Shed Coordinator or CLSC), and the Demand Response Capacity Assessment & Operation Assistance Tool (DRCAOT). In addition, an innovative data aggregator called sMAP (simple Measurement and Actuation Profile) allowed data from different sources collected in a compact form and facilitated detailed analysis of the building systems operation. A smart phone application (RAP or Rapid Audit Protocol) facilitated an inventory of the building’s plug loads. Carbon dioxide sensors located in conference rooms and classrooms allowed demand controlled ventilation. The extensive submetering and nimble access to this data provided great insight into the details of the building operation as well as quick diagnostics and analyses of tests. For example, students discovered a short-cycling chiller, a stuck damper, and a leaking cooling coil in the first field tests. For our final field tests, we were able to see how each zone was affected by the DR strategies (e.g., the offices on the 7th floor grew very warm quickly) and fine-tune the strategies accordingly.« less
Integrated Reconfigurable Intelligent Systems (IRIS) for Complex Naval Systems
2009-10-31
water system. This simplified chilled water system includes one chiller -pump plant and two service loads. • X- p«cM*MJ<w*4tf -a ’.•.wVlniX’i • V...and valve7. Pumps and chiller operation states are observable. Valve 7 is STUCKCLOSE at time / = 440sec (me 11th iteration). Valve 11 is STUCKCLOSE...framework is a product from Adobe called Flex. The product is a mixture of the Adobe Action script programming language and a markup language call MXML
Predictions of Energy Savings in HVAC Systems by Lumped Models (Preprint)
2010-04-14
various control devices into a simulated HVAC system. Con- trols contain a setpoint of 26.7oC. The adjustable damper, variable chiller work input, and variable fanspeed contain values of αP of -1.0, 0.1, and 1.0, respectively. 25 ...Villanova, PA 19085 bCode 985, Naval System Warfare Center, Carderock Division, Philadelphia, PA 19112 Abstract An approach to optimizing the energy...suggest an order of mag- nitude greater energy savings using a variable chiller power control approach compared to control damper and variable-drive
Optimizing Performance of a Thermal Energy Storage System
NASA Astrophysics Data System (ADS)
Subirats Soler, Monica
In this thesis, the problem of electricity demand shifting for the cooling needs of a large institution using a thermal energy storage (TES) tank is considered. The system is formed by electric chillers, cooling towers and a TES tank that can store energy for the cooling demand of most days, but not for the hottest ones. The goal is to supply all the cooling needed while minimizing the cost. This is done by shifting the cooling demand to night and early morning hours, when electricity is cheaper and due to lower temperatures, the chillers work more efficiently. This is all done with the help of the TES tank, that acts as a buffer storing chilled water. After a series of assumptions and simplifications, the cost function becomes convex and thus a minimum solution exists. However, from previous work only the chillers were considered, omitting the negative effect that other components of the system, such as cooling towers, had on the overall cost of operation. Using data from the operation of the power plant under real conditions, a method to model the whole system is presented in this thesis. In addition, the algorithm relied on the knowledge of an accurate prediction of the cooling demand, which obviously is not known in advance. A method to predict it starting from a forecasting of the temperature is presented. Finally, the algorithm can be easily modified to allow the imposition constraints that limit the maximum power use of chillers, during specific periods, in response to the overall needs of the micro-grid.
King, Christopher; Robinson, Timothy; Dixon, C Edward; Rao, Gutti R; Larnard, Donald; Nemoto, C Edwin M
2010-10-01
Therapeutic hypothermia remains a promising treatment for patients with severe traumatic brain injury (TBI). Multiple animal studies have suggested that hypothermia is neuroprotective after TBI, but clinical trials have been inconclusive. Systemic hypothermia, the method used in almost all major clinical trials, is limited by the time to target temperature, the depth of hypothermia, and complications, problems that may be solved by selective brain cooling. We evaluated the effects on brain temperature of a cooling device called the ChillerPad,™ which is applied to the dura in a non-human primate TBI model using controlled cortical impact (CCI). The cortical surface was rapidly cooled to approximately 15°C and maintained at that level for 24 h, followed by rewarming over about 10 h. Brain temperatures fell to 34-35°C at a depth of 15 mm at the cortical gray/white matter interface, and to 28-32°C at 10 mm deep. Intracranial pressure was mildly elevated (8-12 mm Hg) after cooling and rewarming, likely due to TBI. Other physiological variables were unchanged. Cooling was rapidly diminished at points distant from the cooling pad. The ChillerPad may be useful for highly localized cooling of the brain in circumstances in which a craniotomy is clinically indicated. However, because of the delay required by the craniotomy, other methods that are more readily available for inducing hypothermia may be used as a bridge between the time of injury to placement of the ChillerPad.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jenks, Jeromy WJ; TeGrotenhuis, Ward E.; Motkuri, Radha K.
2015-07-09
Metal-organic frameworks (MOFs) have recently attracted enormous interest over the past few years due to their potential applications in energy storage and gas separation. However, there have been few reports on MOFs for adsorption cooling applications. Adsorption cooling technology is an established alternative to mechanical vapor compression refrigeration systems. Adsorption cooling is an excellent alternative in industrial environments where waste heat is available. Applications also include hybrid systems, refrigeration, power-plant dry cooling, cryogenics, vehicular systems and building HVAC. Adsorption based cooling and refrigeration systems have several advantages including few moving parts and negligible power consumption. Key disadvantages include large thermalmore » mass, bulkiness, complex controls, and low COP (0.2-0.5). We explored the use of metal organic frameworks that have very high mass loading and relatively low heats of adsorption, with certain combinations of refrigerants to demonstrate a new type of highly efficient adsorption chiller. An adsorption chiller based on MOFs suggests that a thermally-driven COP>1 may be possible with these materials, which would represent a fundamental breakthrough in performance of adsorption chiller technology. Computational fluid dynamics combined with a system level lumped-parameter model have been used to project size and performance for chillers with a cooling capacity ranging from a few kW to several thousand kW. In addition, a cost model has been developed to project manufactured cost of entire systems. These systems rely on stacked micro/mini-scale architectures to enhance heat and mass transfer. Presented herein are computational and experimental results for hydrophyilic MOFs, fluorophilic MOFs and also flourophilic Covalent-organic frameworks (COFs).« less
Manufacturing Competitiveness and Supply Chain Analyses for Hydrogen Refueling Stations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mayyas, Ahmad T; Garland, Nancy
This slide deck was presented in the monthly FCTO webinar series (May 2017). The goal of this presentation was to share our latest results and remarks on the manufacturing competitiveness analysis of the hydrogen refueling stations (HRS). Manufacturing cost models were developed for major systems in the HRS such as compressors, storage tanks, chillers, heat exchangers, and dispensers. In addition to the cost models, we also discussed important remarks from our analysis for the international trade flows and global supply chain for the hydrogen refueling stations. The last part of the presentation also highlights effect of economies of scale andmore » high production volumes on lowering the cost of the hydrogen at the pump.« less
NASA Astrophysics Data System (ADS)
Finley, Christopher
Power generation using wind turbines increases the electrical system balancing, regulation and ramp rate requirements due to the minute to minute variability in wind speed and the difficulty in accurately forecasting wind speeds. The addition of thermal energy storage, such as ice storage, to a building's space cooling equipment increases the operational flexibility of the equipment by allowing the owner to choose when the chiller is run. The ability of the building owner to increase the power demand from the chiller (e.g. make ice) or to decrease the power demand (e.g. melt ice) to provide electrical system ancillary services was evaluated.
Advances in thermal control and performance of the MMT M1 mirror
NASA Astrophysics Data System (ADS)
Gibson, J. D.; Williams, G. G.; Callahan, S.; Comisso, B.; Ortiz, R.; Williams, J. T.
2010-07-01
Strategies for thermal control of the 6.5-meter diameter borosilicate honeycomb primary (M1) mirror at the MMT Observatory have included: 1) direct control of ventilation system chiller setpoints by the telescope operator, 2) semiautomated control of chiller setpoints, using a fixed offset from the ambient temperature, and 3) most recently, an automated temperature controller for conditioned air. Details of this automated controller, including the integration of multiple chillers, heat exchangers, and temperature/dew point sensors, are presented here. Constraints and sanity checks for thermal control are also discussed, including: 1) mirror and hardware safety, 2) aluminum coating preservation, and 3) optimization of M1 thermal conditions for science acquisition by minimizing both air-to-glass temperature differences, which cause mirror seeing, and internal glass temperature gradients, which cause wavefront errors. Consideration is given to special operating conditions, such as high dew and frost points. Precise temperature control of conditioned ventilation air as delivered to the M1 mirror cell is also discussed. The performance of the new automated controller is assessed and compared to previous control strategies. Finally, suggestions are made for further refinement of the M1 mirror thermal control system and related algorithms.
NASA Astrophysics Data System (ADS)
Wang, Qingze; Chen, Xingying; Ji, Li; Liao, Yingchen; Yu, Kun
2017-05-01
The air-conditioning system of office building is a large power consumption terminal equipment, whose unreasonable operation mode leads to low energy efficiency. Realizing the optimization of the air-conditioning system has become one of the important research contents of the electric power demand response. In this paper, in order to save electricity cost and improve energy efficiency, bi-level optimization method of air-conditioning system based on TOU price is put forward by using the energy storage characteristics of the office building itself. In the upper level, the operation mode of the air-conditioning system is optimized in order to minimize the uses’ electricity cost in the premise of ensuring user’ comfort according to the information of outdoor temperature and TOU price, and the cooling load of the air-conditioning is output to the lower level; In the lower level, the distribution mode of cooling load among the multi chillers is optimized in order to maximize the energy efficiency according to the characteristics of each chiller. Finally, the experimental results under different modes demonstrate that the strategy can improve the energy efficiency of chillers and save the electricity cost for users.
Efficiency analysis of semi-open sorption heat pump systems
Gluesenkamp, Kyle R.; Chugh, Devesh; Abdelaziz, Omar; ...
2016-08-10
Sorption systems traditionally fall into two categories: closed (heat pumps and chillers) and open (dehumidification). Recent work has explored the possibility of semi-open systems, which can perform heat pumping or chilling while utilizing ambient humidity as the working fluid of the cycle, and are still capable of being driven by solar, waste, or combustion heat sources. The efficiencies of closed and open systems are well characterized, and can typically be determined from four temperature s. In this work, the performance potential of semi-open systems is explored by adapting expressions for the efficiency of closed and open systems to the novelmore » semi-open systems. A key new parameter is introduced, which involves five temperatures, since both the ambient dry bulb and ambient dew point are used. Furthermore, this additional temperature is necessary to capture the open absorber performance in terms of both the absorption of humidity and sensible heat transfer with surrounding air.« less
Smart grid integration of small-scale trigeneration systems
NASA Astrophysics Data System (ADS)
Vacheva, Gergana; Kanchev, Hristiyan; Hinov, Nikolay
2017-12-01
This paper presents a study on the possibilities for implementation of local heating, air-conditioning and electricity generation (trigeneration) as distributed energy resource in the Smart Grid. By the means of microturbine-based generators and absorption chillers buildings are able to meet partially or entirely their electrical load curve or even supply power to the grid by following their heating and air-conditioning daily schedule. The principles of small-scale cooling, heating and power generation systems are presented at first, then the thermal calculations of an example building are performed: the heat losses due to thermal conductivity and the estimated daily heating and air-conditioning load curves. By considering daily power consumption curves and weather data for several winter and summer days, the heating/air-conditioning schedule is estimated and the available electrical energy from a microturbine-based cogeneration system is estimated. Simulation results confirm the potential of using cogeneration and trigeneration systems for local distributed electricity generation and grid support in the daily peaks of power consumption.
Efficiency analysis of semi-open sorption heat pump systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gluesenkamp, Kyle R.; Chugh, Devesh; Abdelaziz, Omar
Sorption systems traditionally fall into two categories: closed (heat pumps and chillers) and open (dehumidification). Recent work has explored the possibility of semi-open systems, which can perform heat pumping or chilling while utilizing ambient humidity as the working fluid of the cycle, and are still capable of being driven by solar, waste, or combustion heat sources. The efficiencies of closed and open systems are well characterized, and can typically be determined from four temperature s. In this work, the performance potential of semi-open systems is explored by adapting expressions for the efficiency of closed and open systems to the novelmore » semi-open systems. A key new parameter is introduced, which involves five temperatures, since both the ambient dry bulb and ambient dew point are used. Furthermore, this additional temperature is necessary to capture the open absorber performance in terms of both the absorption of humidity and sensible heat transfer with surrounding air.« less
Levitt, Michael D.; Levitt, David G.
1973-01-01
Measurement of the relative absorption rates of inert gases (H2, He, CH4, SF6, and 133Xe) was used to investigate the interaction between diffusion and blood flow during passive absorption from the stomach, small bowel, and colon of the rat. If uptake is blood flow limited, the gases should be absorbed in proportion to their solubilities in blood, but if diffusion limited, uptake should be proportional to the diffusion rate of the gases in mucosal tissues. The observed absorption data were fitted to a series of models of interaction between perfusion and diffusion. A simple model accurately predicted the absorption rates of the gases from all segments of bowel. In this model, gas is absorbed into two distinct blood flows: one which flows in proximity to the lumen and completely equilibrates with the lumen, and a second which is sufficiently rapid and distant from the lumen that its gas uptake is entirely diffusion limited. The fraction of the total absorption attributable to the equilibrating flow can be readily calculated and equalled 93%, 77%, and 33% for the small bowel, colon, and stomach, respectively. Thus the rate of passive absorption of gases from the small bowel is limited almost entirely by the blood flow to the mucosa, and absorption from the stomach is largely limited by the diffusion rate of the gases. The flow which equilibrates with the lumen can be quantitated, and this flow may provide a useful measure of “effective” mucosal blood flow. Images PMID:4719667
Radiant energy absorption studies for laser propulsion. [gas dynamics
NASA Technical Reports Server (NTRS)
Caledonia, G. E.; Wu, P. K. S.; Pirri, A. N.
1975-01-01
A study of the energy absorption mechanisms and fluid dynamic considerations for efficient conversion of high power laser radiation into a high velocity flow is presented. The objectives of the study are: (1) to determine the most effective absorption mechanisms for converting laser radiation into translational energy, and (2) to examine the requirements for transfer of the absorbed energy into a steady flow which is stable to disturbances in the absorption zone. A review of inverse Bremsstrahlung, molecular and particulate absorption mechanisms is considered and the steady flow and stability considerations for conversion of the laser power to a high velocity flow in a nozzle configuration is calculated. A quasi-one-dimensional flow through a nozzle was formulated under the assumptions of perfect gas.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-05-31
The Scope of Work called for the study of the economic feasibility of providing a cold thermal storage system at the central chiller plant serving the Fort Leonard Wood 600 Area in order to reduce electrical demand charges. In the Entry Interview, Mr. Doug Cage requested that the analysis include the potential for expansion of such a system to serve the 700 and 800 Areas as well. It was agreed that this would be done if the analysis indicated that a cold thermal storage system would be economically feasible for Area 600. The 600 Area study area is comprised ofmore » two different build types, mess halls and barracks. The mess halls are all essentially identical with the exception that site orientation varies by building. The same is true for the barracks buildings. A baseline case was calculated under the basis that the future chilled water plant for the area under analysis would be served by a centrifugal chiller. This was done because there is no existing baseline condition against which thermal storage systems may be compared. The existing chiller serves Area 600 plus a portion of Area 700. In addition, its age is such that it is reasonable to expect that it will be replaced in the near future.« less
Solar Thermal Demonstration Project
DOE Office of Scientific and Technical Information (OSTI.GOV)
Biesinger, K; Cuppett, D; Dyer, D
2012-01-30
HVAC Retrofit and Energy Efficiency Upgrades at Clark High School, Las Vegas, Nevada The overall objectives of this project are to increase usage of alternative/renewable fuels, create a better and more reliable learning environment for the students, and reduce energy costs. Utilizing the grant resources and local bond revenues, the District proposes to reduce electricity consumption by installing within the existing limited space, one principal energy efficient 100 ton adsorption chiller working in concert with two 500 ton electric chillers. The main heating source will be primarily from low nitrogen oxide (NOX), high efficiency natural gas fired boilers. With themore » use of this type of chiller, the electric power and cost requirements will be greatly reduced. To provide cooling to the information technology centers and equipment rooms of the school during off-peak hours, the District will install water source heat pumps. In another measure to reduce the cooling requirements at Clark High School, the District will replace single pane glass and metal panels with Kalwall building panels. An added feature of the Kalwall system is that it will allow for natural day lighting in the student center. This system will significantly reduce thermal heat/cooling loss and control solar heat gain, thus delivering significant savings in heating ventilation and air conditioning (HVAC) costs.« less
Truck Thermoacoustic Generator and Chiller
DOE Office of Scientific and Technical Information (OSTI.GOV)
Keolian, Robert
2011-03-31
This Final Report describes the accomplishments of the US Department of Energy (DOE) cooperative agreement project DE-FC26-04NT42113 - Truck Thermoacoustic Generator and Chiller - whose goal is to design, fabricate and test a thermoacoustic piezoelectric generator and chiller system for use on over-the-road heavy-duty-diesel trucks, driven alternatively by the waste heat of the main diesel engine exhaust or by a burner integrated into the thermoacoustic system. The thermoacoustic system would utilize engine exhaust waste heat to generate electricity and cab air conditioning, and would also function as an auxiliary power unit (APU) for idle reduction. The unit was to bemore » tested in Volvo engine performance and endurance test cells and then integrated onto a Class 8 over-the-road heavy-duty-diesel truck for further testing on the road. The project has been a collaboration of The Pennsylvania State University Applied Research Laboratory, Los Alamos National Laboratory, Clean Power Resources Inc., and Volvo Powertrain (Mack Trucks Inc.). Cost share funding was provided by Applied Research Laboratory, and by Clean Power Resources Inc via its grant from Innovation Works - funding that was derived from the Commonwealth of Pennsylvania. Los Alamos received its funding separately through DOE Field Work Proposal 04EE09.« less
de Lange, Martijn F; van Velzen, Benjamin L; Ottevanger, Coen P; Verouden, Karlijn J F M; Lin, Li-Chiang; Vlugt, Thijs J H; Gascon, Jorge; Kapteijn, Freek
2015-11-24
A large fraction of global energy is consumed for heating and cooling. Adsorption-driven heat pumps and chillers could be employed to reduce this consumption. MOFs are often considered to be ideal adsorbents for heat pumps and chillers. While most published works to date on this topic have focused on the use of water as a working fluid, the instability of many MOFs to water and the fact that water cannot be used at subzero temperatures pose certain drawbacks. The potential of using alcohol-MOF pairs in adsorption-driven heat pumps and chillers is investigated. To this end, 18 different selected MOF structures in combination with either methanol or ethanol as a working fluid are considered, and their potential is assessed on the basis of adsorption measurements and thermodynamic efficiencies. If alcohols are used instead of water, then (1) adsorption occurs at lower relative pressures for methanol and even lower pressure for ethanol, (2) larger pores can be utilized efficiently, as hysteresis is absent for pores smaller than 3.4 nm (2 nm for water), (3) larger pore sizes need to be employed to ensure the desired stepwise adsorption, (4) the effect of (polar/apolar) functional groups in the MOF is far less pronounced, (5) the energy released or taken up per cycle is lower, but heat and mass transfer may be enhanced, (6) stability of MOFs seems to be less of an issue, and (7) cryogenic applications (e.g., ice making) become feasible. From a thermodynamic perspective, UiO-67, CAU-3, and ZIF-8 seem to be the most promising MOFs for both methanol and ethanol as working fluids. Although UiO-67 might not be completely stable, both CAU-3 and ZIF-8 have the potential to be applied, especially in subzero-temperature adsorption chillers (AC).
Case Study for the ARRA-Funded Ground Source Heat Pump Demonstration at Ball State University
DOE Office of Scientific and Technical Information (OSTI.GOV)
Im, Piljae; Liu, Xiaobing; Henderson, Jr., Hugh
With funding provided by the American Recovery and Reinvestment Act (ARRA), 26 ground-source heat pump (GSHP) projects were competitively selected in 2009 to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. One of the selected demonstration projects is a district central GSHP system installed at Ball State University (BSU) in Muncie, IN. Prior to implementing the district GSHP system, 47 major buildings in BSU were served by a central steam plant with four coal-fired and three natural-gas-fired steam boilers. Cooling was provided by five water-cooled centrifugal chillers at the District Energy Station Southmore » (DESS). The new district GSHP system replaced the existing coal-fired steam boilers and conventional water-cooled chillers. It uses ground-coupled heat recovery (HR) chillers to meet the simultaneous heating and cooling demands of the campus. The actual performance of the GSHP system was analyzed based on available measured data from August 2015 through July 2016, construction drawings, maintenance records, personal communications, and construction costs. Since Phase 1 was funded in part by the ARRA grant, it is the focus of this case study. The annual energy consumption of the GSHP system was calculated based on the available measured data and other related information. It was compared with the performance of a baseline scenario— a conventional water-cooled chiller and natural-gas-fired boiler system, both of which meet the minimum energy efficiencies allowed by the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE 90.1-2013). The comparison was made to determine source energy savings, energy cost savings, and CO2 emission reductions achieved by the GSHP system. A cost analysis was performed to evaluate the simple payback of the GSHP system. The following sections summarize the results of the analysis, the lessons learned, and recommendations for improvement in the operation of this district GSHP system.« less
Split-flow regeneration in absorptive air separation
Weimer, Robert F.
1987-01-01
A chemical absorptive separation of air in multiple stage of absorption and desorption is performed with partial recycle of absorbent between stages of desorption necessary to match equilibrium conditions in the various stages of absorption. This allows reduced absorbent flow, reduced energy demand and reduced capital costs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Qu, Ming; Abdelaziz, Omar; Yin, Hongxi
2014-11-01
Conventional natural gas-fired boilers exhaust flue gas direct to the atmosphere at 150 200 C, which, at such temperatures, contains large amount of energy and results in relatively low thermal efficiency ranging from 70% to 80%. Although condensing boilers for recovering the heat in the flue gas have been developed over the past 40 years, their present market share is still less than 25%. The major reason for this relatively slow acceptance is the limited improvement in the thermal efficiency of condensing boilers. In the condensing boiler, the temperature of the hot water return at the range of 50 60more » C, which is used to cool the flue gas, is very close to the dew point of the water vapor in the flue gas. Therefore, the latent heat, the majority of the waste heat in the flue gas, which is contained in the water vapor, cannot be recovered. This paper presents a new approach to improve boiler thermal efficiency by integrating absorption heat pumps with natural gas boilers for waste heat recovery (HRAHP). Three configurations of HRAHPs are introduced and discussed. The three configurations are modeled in detail to illustrate the significant thermal efficiency improvement they attain. Further, for conceptual proof and validation, an existing hot water-driven absorption chiller is operated as a heat pump at operating conditions similar to one of the devised configurations. An overall system performance and economic analysis are provided for decision-making and as evidence of the potential benefits. These three configurations of HRAHP provide a pathway to achieving realistic high-efficiency natural gas boilers for applications with process fluid return temperatures higher than or close to the dew point of the water vapor in the flue gas.« less
Split-flow regeneration in absorptive air separation
Weimer, R.F.
1987-11-24
A chemical absorptive separation of air in multiple stage of absorption and desorption is performed with partial recycle of absorbent between stages of desorption necessary to match equilibrium conditions in the various stages of absorption. This allows reduced absorbent flow, reduced energy demand and reduced capital costs. 4 figs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Isfahani, RN; Moghaddam, S
An experimental study on absorption characteristics of water vapor into a thin lithium bromide (LiBr) solution flow is presented. The LiBr solution flow is constrained between a superhydrophobic vapor permeable wall and a solid surface that removes the heat of absorption. As opposed to conventional falling film absorbers, in this configuration, the solution film thickness and velocity can be controlled independently to enhance the absorption rate. The effects of water vapor pressure, cooling surface temperature, solution film thickness, and solution flow velocity on the absorption rate are studied. An absorption rate of approximately 0.006 kg/m(2) s was measured at amore » LiBr solution channel thickness and flow velocity of 100 mu m and 5 mm/s, respectively. The absorption rate increased linearly with the water vapor driving potential at the test conditions of this study. It was demonstrated that decreasing the solution film thickness and increasing the solution velocity enhance the absorption rate. The high absorption rate and the inherently compact form of the proposed,absorber facilitate development of compact small-scale waste heat or solar-thermal driven cooling systems. Published by Elsevier Ltd.« less
48 CFR 23.804 - Contract clauses.
Code of Federal Regulations, 2010 CFR
2010-10-01
... refrigerant, such as air conditioners, including motor vehicles, refrigerators, chillers, or freezers. [61 FR... Equipment and Air Conditioners, in solicitations and contracts for services when the contract includes the...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kucha, E.I.
1984-01-01
A general method was developed to calculate two dimensional (axisymmetric) mixing of a compressible jet in a variable cross-sectional area mixing channel of the ejector. The analysis considers mixing of the primary and secondary fluids at constant pressure and incorporates finite difference approximations to the conservation equations. The flow model is based on the mixing length approximations. A detailed study and modeling of the flow phenomenon determines the best (optimum) mixing channel geometry of the ejector. The detailed ejector performance characteristics are predicted by incorporating the flow model into a solar-powered ejector cycle cooling system computer model. Freon-11 is usedmore » as both the primary and secondary fluids. Performance evaluation of the cooling system is examined for its coefficient of performance (COP) under a variety of operating conditions. A study is also conducted on a modified ejector cycle in which a secondary pump is introduced at the exit of the evaporator. Results show a significant improvement in the overall performance over that of the conventional ejector cycle (without a secondary pump). Comparison between one and two-dimensional analyses indicates that the two-dimensional ejector fluid flow analysis predicts a better overall system performance. This is true for both the conventional and modified ejector cycles.« less
The measurement of energy consumption by exercise bikes
NASA Astrophysics Data System (ADS)
Jwo, Ching-Song; Chien, Chao-Chun; Jeng, Lung-Yue
2006-11-01
This paper is intended as an investigation is that to measure the amount of energy consumption can be consumed by riding bikes and also could recycle the consuming energy during exercising. Exercisers ride the bicycle inputting the driving force through a compressor of refrigeration system, which can circulate the refrigerant in the system and calculate the calorific capacity from the spread of the condenser. In addition, we can make up chiller water in the evaporator. Experiments were performed to prove the hypotheses. Therefore, this experiment has designed the sports goods which reach the purpose of doing exercise, measuring accurately the consuming calorific capacity and having the function of making chiller water. After exercising, you can drink the water producing during exercise and apply on the system of air conditioner, which attains two objectives.
NASA Astrophysics Data System (ADS)
Di, Yue; Jin, Yi; Jiang, Hong-liang; Zhai, Chao
2013-09-01
Due to the particularity of the high-speed flow, in order to accurately obtain its' temperature, the measurement system should has some characteristics of not interfereing with the flow, non-contact measurement and high time resolution. The traditional measurement method cannot meet the above requirements, however the measurement method based on tunable diode laser absorption spectroscopy (TDLAS) technology can meet the requirements for high-speed flow temperature measurement. When the near-infared light of a specific frequency is through the media to be measured, it will be absorbed by the water vapor molecules and then the transmission light intensity is detected by the detector. The temperature of the water vapor which is also the high-speed flow temperature, can be accurately obtained by the Beer-Lambert law. This paper focused on the research of absorption spectrum method for high speed flow temperature measurement with the scope of 250K-500K. Firstly, spectral line selection method for low temperature measurement of high-speed flow is discussed. Selected absorption lines should be isolated and have a high peak absorption within the range of 250-500K, at the same time the interference of the other lines should be avoided, so that a high measurement accuracy can be obtained. According to the near-infrared absorption spectra characteristics of water vapor, four absorption lines at the near 1395 nm and 1409 nm are selected. Secondly, a system for the temperature measurement of the water vapor in the high-speed flow is established. Room temperature are measured through two methods, direct absorption spectroscopy (DAS) and wavelength modulation spectroscopy (WMS) ,the results show that this system can realize on-line measurement of the temperature and the measurement error is about 3%. Finally, the system will be used for temperature measurement of the high-speed flow in the shock tunnel, its feasibility of measurement is analyzed.
Lü, Xiao-jing; Li, Ning; Weng, Chun-sheng
2016-03-01
Compared with traditional sampling-based sensing method, absorption spectroscopy technology is well suitable for detonation flow diagnostics, since it can provide with us fast response, nonintrusive, sensitive solution for situ measurements of multiple flow-field parameters. The temperature and concentration test results are the average values along the laser path with traditional absorption spectroscopy technology, while the boundary of detonation flow external field is unknown and it changes all the time during the detonation engine works, traditional absorption spectroscopy technology is no longer suitable for detonation diagnostics. The trend of line strength with temperature varies with different absorption lines. By increasing the number of absorption lines in the test path, more information of the non-uniform flow field can be obtained. In this paper, based on multispectral absorption technology, the reconstructed model of detonation flow external field distribution was established according to the simulation results of space-time conservation element and solution element method, and a diagnostic method of detonation flow external field was given. The model deviation and calculation error of the least squares method adopted were studied by simulation, and the maximum concentration and temperature calculation error was 20.1% and 3.2%, respectively. Four absorption lines of H2O were chosen and detonation flow was scanned at the same time. The detonation external flow testing system was set up for the valveless gas-liquid continuous pulse detonation engine with the diameter of 80 mm. Through scanning H2O absorption lines with a high frequency of 10 kHz, the on-line detection of detonation external flow was realized by direct absorption method combined with time-division multiplexing technology, and the reconstruction of dynamic temperature distribution was realized as well for the first time, both verifying the feasibility of the test method. The test results show that both of the temperature and H2O concentration rose with the arrival of detonation wave. With the increase of the vertical distance between the detonation tube nozzle and the laser path, the time of temperature and concentration coming to the peak delayed, and the temperature variation trend tended to slow down. At 20 cm from detonation tube nozzle, the maximum temperature hit 1 329 K and the maximum H2O concentration of 0.19 occurred at 4 ms after ignition. The research can provide with us the support for expanding the detonation test field with absorption spectroscopy technology, and can also help to promote the detonation mechanism research and to enhance the level of detonation engine control technology.
Leveraging gigawatt potentials by smart heat-pump technologies using ionic liquids.
Wasserscheid, Peter; Seiler, Matthias
2011-04-18
One of the greatest challenges to science in the 21 st century is the development of efficient energy production, storage, and transformation systems with minimal ecological footprints. Due to the lack of efficient heat-transformation technologies, industries around the world currently waste energy in the gigawatt range at low temperatures (40-80 °C). These energy potentials can be unlocked or used more efficiently through a new generation of smart heat pumps operating with novel ionic liquid (IL)-based working pairs. The new technology is expected to allow revolutionary technical progress in heat-transformation devices, for example, significantly higher potential efficiencies, lower specific investments, and broader possibilities to incorporate waste energy from renewable sources. Furthermore, due to drastically reduced corrosion rates and excellent thermal stabilities of the new, IL-based working pairs, the high driving temperatures necessary for multi-effect cycles such as double- or triple-effect absorption chillers, can also be realized. The details of this novel and innovative heat-transformation technology are described. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
A program for solar energy utilization in spain
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perches-Escandell, J.; Lorsch, H.G.
1983-06-01
The Spanish Association of Electric Utilities (UNESA) and the state-owned industrial holding company (INI) have undertaken a 5-year program for the more efficient utilization of energy through solar energy and other energy conserving technologies. Among the tasks undertaken was the design of a solar collector particularly well suited to Spanish conditions. More than 28,000 m/sup 2/ of this collector have been installed, accounting for 42% of the Spanish market over the past three years. In cooperation with the Franklin Research Center of Philadelphia, PA, the UNESA-INI staff has carried out a binational program of solar energy utilization, funded under themore » U.S. -Spanish Treaty of Friendship and Cooperation. As a part of this program, five demonstration projects have been constructed or are under construction. Four of them provide space heating and cooling and service water heating by means of evacuated tube collectors, EPDM collectors, air heating collectors, a water-to-water heat pump, and an absorption chiller; a fifth generates electricity by means of photovoltaic cells.« less
Bond, John H.; Levitt, David G.; Levitt, Michael D.
1974-01-01
The purpose of the present study was to quantitate the influence of countercurrent exchange on passive absorption of highly diffusible substances from the small intestine of the rabbit. The absorption of carbon monoxide, which is tightly bound to hemoglobin and therefore cannot exchange, was compared to the absorption of four unbound gases (H2, He, CH4, and 133Xe), which should exchange freely. The degree to which the observed absorption of the unbound gases falls below that predicted from CO absorption should provide a quantitative measure of countercurrent exchange. CO uptake at high luminal Pco is flow-limited and, assuming that villus and central hemoglobin concentrations are equal, the flow that equilibrates with CO (Fco) was calculated to equal 7.24 ml/min/100 g. The observed absorption rate of the unbound gases was from two to four times greater than would have been predicted had their entire uptake been accounted for by equilibration with Fco. This is the opposite of what would occur if countercurrent exchange retarded absorption of the unbound gases. The unbound gases have both flow- and diffusion-limited components, and Fco should account for only the fraction of absorption that is flow limited. A simple model of perfusion and diffusion made it possible to calculate the fraction of the total uptake of unbound gases that was flow limited. This fraction of the total observed absorption rate was still about 1.8 times greater than predicted by CO absorption. A possible explanation for this discrepancy is that plasma skimming reduces the hemoglobin of villus blood to about 60% of that of central blood. Thus, Fco is actually about 1.7 times greater than initially calculated, and with this correction, there is close agreement between the predicted and observed rates of absorption of each of the unbound gases. We conclude that countercurrent exchange does not influence passive absorption under the conditions of this study. PMID:4436431
33. SITE BUILDING 002 SCANNER BUILDING MECHANICAL ROOM ...
33. SITE BUILDING 002 - SCANNER BUILDING - MECHANICAL ROOM 105, VIEW OF CHILLER ROOM MOTOR CONTROL CENTER. - Cape Cod Air Station, Technical Facility-Scanner Building & Power Plant, Massachusetts Military Reservation, Sandwich, Barnstable County, MA
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martin, M.A.; Durfee, D.J.; Hughes, P.J.
1999-06-19
The Lincoln Public School District, in Lincoln, Nebraska, recently installed vertical-bore geothermal heat pump systems in four, new, elementary schools. Because the district has consistent maintenance records and procedures, it was possible to study repair, service and corrective maintenance requests for 20 schools in the district. Each school studied provides cooling to over 70% of its total floor area and uses one of the following heating and cooling systems: vertical-bore geothermal heat pumps (GHPs), air-cooled chiller with gas-fired hot water boiler (ACUGHWB), water-cooled chiller with gas-fired hot water boiler (WCCYGHWB), or water-cooled chiller with gas-fired steam boiler (WCUGSB). Preventative maintenancemore » and capital renewal activities were not included in the available database. GHP schools reported average total costs at 2.13 cents/ft{sup 2}-yr, followed by ACC/GHWB schools at 2.88 cents/ft{sup 2}-yr, WCC/GSB schools at 3.73 cents/ft{sup 2}-yr, and WCC/GHWB schools at 6.07 cents/ft{sup 2}-yr. Because of tax-exemptions on material purchases, a reliance on in-house labor, and the absence of preventative maintenance records in the database, these costs are lower than those reported in previous studies. A strong relationship (R{sup 2}=O.52) was found between costs examined and cooling system age: the newer the cooling equipment, the less it costs to maintain.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martin, M.A.; Durfee, D.J.; Hughes, P.J.
1999-07-01
The Lincoln Public School District, in Lincoln, Nebraska, recently installed vertical-bore geothermal heat pump systems in four new elementary schools. Because the district has consistent maintenance records and procedures, it was possible to study repair, service, and corrective maintenance requests for 20 schools in the district. Each school studied provides cooling to over 70% of its total floor area and uses one of the following heating and cooling systems: vertical-bore geothermal heat pumps (GHPs), air-cooled chiller with gas-fired hot water boiler (ACC/GHWB), water-cooled chiller with gas-fired hot water boiler (WCC/GHWB), or water-cooled chiller with gas-fired steam boiler (WCC/GSB). Preventative maintenancemore » and capital renewal activities were not included in the available database. GHP schools reported average total costs at 2.13{cents}/ft{sup 2}-yr, followed by ACC/GHWB schools at 2.884{cents}/ft{sup 2}-yr, WCC/GSB schools at 3.73{cents}/ft{sup 2}-yr, and WCC/GHWB schools at 6.07{cents}/ft{sup 2}-yr. Because of tax exemptions on material purchases, a reliance on in-house labor, and the absence of preventative maintenance records in the database, these costs are lower than those reported in previous studies. A strong relationship (R{sup 2} = 0.52) was found between costs examined and cooling system age: the newer the cooling equipment, the less it costs to maintain.« less
Teaching Political Science with Chillers and Thrillers.
ERIC Educational Resources Information Center
Neuse, Steven M.
1980-01-01
Discusses using popular detective and espionage fiction in courses related to area politics, international relations, political terrorism, socialization, and bureaucratic politics. Suggests several novels and ways in which they may be integrated into courses. (KC)
NASA Astrophysics Data System (ADS)
Purba, Elida; Agustina, Dewi; Putri Pertama, Finka; Senja, Fita
2018-03-01
This research was carried out on the absorption of CO2 from the modified flue gases of power generation Tarahan using NaOH (sodium hydroxide) and Na2CO3 (sodium carbonate). The operation was conducted in a packed column absorber and then the output gases from the packed column was fed into photo-bioreactor for biological absorption. In the photo-bioreactor, two species of microalgae, N. occulata and T. chuii, were cultivated to both absorb CO2 gas and to produce biomass for algal oil. The aims of this research were, first, to determine the effect of absorbent flow rate on the reduction of CO2 and on the decrease of output gas temperature, second, to determine the characteristics of methyl ester obtained from biological absorption process. Flow rates of the absorbent were varied as 1, 2, and 3 l/min. The concentrations of NaOH and Na2CO3 were 1 M at a constant gas flow rate of 6 l/min. The output concentrations of CO2 from the absorber was analyzed using Gas Chromatography 2014-AT SHIMADZU Corp 08128. The results show that both of the absorbents give different trends. From the absorption using NaOH, it can be concluded that the higher the flow rate, the higher the absorption rate obtained. The highest flow rate achieved maximum absorption of 100%. On the other hand, absorption with Na2CO3 revealed the opposite trend where the higher the flow rates the lower the absorption rate. The highest absorption using Na2CO3 was obtained with the lowest flow rate, 1 l/min, that was 45,5%. As the effect of flow rate on output gas temperature, the temperature decreased with increasing flow rates for both absorbents. The output gas temperature for NaOH and Na2CO3 were consecutively 35 °C and 31 °C with inlet gas temperature of 50°C. Absorption of CO2 biologically resulted a reduction of CO2 up to 60% from the input gas concentration. Algal oil was extracted with mixed hexane and chloroform to obtain algal oil. Extracted oil was transesterified to methyl ester using sodium hydroxide as a catalyst. The results of in-situ transesterification method cannot be identified. Both microalgae achieved maximum yield at 2% catalyst concentration. Nannochloropsis occulata achieved the highest yield of algal oil that is 88.5%. The highest content of methyl ester from Nannochloropsis occulata was undecanoic acid methyl ester by 55.42% and the result from Tetraselmis chuii was palmitic acid methyl ester by 81.58%.
Mass transfer in thin films under counter-current gas: experiments and numerical study
NASA Astrophysics Data System (ADS)
Lucquiaud, Mathieu; Lavalle, Gianluca; Schmidt, Patrick; Ausner, Ilja; Wehrli, Marc; O Naraigh, Lennon; Valluri, Prashant
2016-11-01
Mass transfer in liquid-gas stratified flows is strongly affected by the waviness of the interface. For reactive flows, the chemical reactions occurring at the liquid-gas interface also influence the mass transfer rate. This is encountered in several technological applications, such as absorption units for carbon capture. We investigate the absorption rate of carbon dioxide in a liquid solution. The experimental set-up consists of a vertical channel where a falling film is sheared by a counter-current gas flow. We measure the absorption occurring at different flow conditions, by changing the liquid solution, the liquid flow rate and the gas composition. With the aim to support the experimental results with numerical simulations, we implement in our level-set flow solver a novel module for mass transfer taking into account a variant of the ghost-fluid formalism. We firstly validate the pure mass transfer case with and without hydrodynamics by comparing the species concentration in the bulk flow to the analytical solution. In a final stage, we analyse the absorption rate in reactive flows, and try to reproduce the experimental results by means of numerical simulations to explore the active role of the waves at the interface.
A modeling study of a centrifugal compressor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Popovic, P.; Shapiro, H.N.
1998-12-31
A centrifugal compressor, which is part of a chlorofluorocarbon R-114 chiller installation, was investigated, operating with a new refrigerant, hydrofluorocarbon R-236ea, a proposed alternative to R-114. A large set of R-236ea operating data, as well as a limited amount of R-114 data, were available for this study. A relatively simple analytical compressor model was developed to describe compressor performance. The model was built upon a thorough literature search, experimental data, and some compressor design parameters. Two original empirical relations were developed, providing a new approach to the compressor modeling. The model was developed in a format that would permit itmore » to be easily incorporated into a complete chiller simulation. The model was found to improve somewhat on the quantitative and physical aspects of a compressor model of the same format found in the literature. It was found that the compressor model is specific to the particular refrigerant.« less
Bonaccorsi, Guglielmo; Lorini, Chiara; Pieralli, Francesca; Pieri, Luca; Sala, Antonino; Tanini, Tommaso; Nasali, Marco; Dall'Olio, Beatrice; Santomauro, Francesca
2016-01-01
The aim of this study is to understand whether the freezing without a rapid blast chiller represents a storage method for food at the end of shelf life that guarantees microbiological food safety, so to be considered an effective tool for the appropriate management of food in charitable organizations. The study has been performed on 90 food samples, among those that a charitable foodservice trust receives by the large-scale distribution. The products have been frozen using a domestic refrigerator. The indicators used were: total aerobic microbial count, Escherichia coli, Salmonella spp, Staphylococcus aureus, Campylobacter spp, sulphite reducing clostridia. The results show that the preservation of the chosen fresh products at the end of shelf life in refrigerators, frozen without the use of chillers, is a potential management strategy to avoid the loss of edible food, while maintaining the safety standards.
Glasser, F; Schmidely, P; Sauvant, D; Doreau, M
2008-05-01
In ruminants, dietary lipids are extensively hydrogenated by rumen micro-organisms, and the extent of this biohydrogenation is a major determinant of long-chain fatty acid profiles of animal products (milk, meat). This paper reports on the duodenal flows of C18 fatty acids and their absorption in the small intestine, using a meta-analysis of a database of 77 experiments (294 treatments). We established equations for the prediction of duodenal flows of various 18-carbon (C18) fatty acids as a function of the intakes of their precursors and other dietary factors (source and/or technological treatment of dietary lipids). We also quantified the influence of several factors modifying rumen metabolism (pH, forage : concentrate ratio, level of intake, fish oil supplementation). We established equations for the apparent absorption of these fatty acids in the small intestine as a function of their duodenal flows. For all C18 unsaturated fatty acids, apparent absorption was a linear function of duodenal flow. For 18:0, apparent absorption levelled off for high duodenal flows. From this database, with fatty acid flows expressed in g/kg dry matter intake, we could not find any significant differences between animal categories (lactating cows, other cattle or sheep) in terms of rumen metabolism or intestinal absorption of C18 fatty acids.
ERIC Educational Resources Information Center
Mineo, Ronald W.; Stehn, John L.
1998-01-01
Discusses the effects of electric power deregulation on an educational facility's planning and purchasing for future power needs. Highlights ways schools can take advantage of deregulation. Examines various chiller technologies and economically assessing these technologies on a life-cycle cost basis. (GR)
High enthalpy arc-heated plasma flow diagnostics by tunable diode laser absorption spectroscopy
NASA Astrophysics Data System (ADS)
Lin, Xin; Chen, Lianzhong; Zeng, Hui; Ou, Dongbin; Dong, Yonghui
2017-05-01
This paper reports the laser absorption measurements of atomic oxygen in the FD04 arc-heater at China Academy of Aerospace Aerodynamics (CAAA). An atomic oxygen absorption line at 777.19 nm is utilizied for detecting the population of electronically excited oxygen atom in an air plasma flow. A scanned-wavelength direct absorption mode is used in this study. The laser is scanned in wavelength across the absorption feature at a rate of 200 Hz. Under the assumption of thermal equilibrium, time-resolved temperature measurements are obtained on one line-of-sight in the arc-heater. The good agreement of the temperature inferred from the sonic throat method suggests the equilibrium assumption is valid. These results illustrate the feasibility of the diode laser sensors for flow parameters in high enthalpy arc-heated facilities.
Absorption coefficients for water vapor at 193 nm from 300 to 1073 K
NASA Technical Reports Server (NTRS)
Kessler, W. J.; Carleton, K. L.; Marinelli, W. J.
1993-01-01
Measurements of the water absorption coefficient at 193 nm from 300 to 1073 K are reported. The measurements were made using broadband VUV radiation and a monochromator-based detection system. The water vapor was generated by a saturator and metered into a flowing, 99 cm absorption cell via a water vapor mass flow meter. The 193 nm absorption coefficient measurements are compared to room temperature and high temperature shock tube measurements with good agreement. The absorption can be parameterized by a nu3 vibrational mode reaction coordinate and the thermal population of the nu3 mode.
Improving turbine performance by cooling inlet air using a waste heat powered ejector refrigerator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kowalski, G.J.
1996-12-31
Stationary turbines are used to produce electricity in many areas of the world. Their performance is adversely affected by high ambient temperatures. Several means of reducing the turbine inlet temperature (offpeak water chiller and ice storage and absorption refrigeration systems) are being proposed as a means of increasing turbine output. In the present investigation the feasibility of increasing turbine output power by using its exhaust gases to power an ejector refrigeration system is demonstrated. The advantages of the ejector refrigeration are: it operates on a non-CFC fluid, its small number of moving parts and its small size. The analysis focusesmore » on United Technologies FT4 turbine with a base load output of 21.6 MW. It is demonstrated that the proposed system can decrease the turbine inlet temperature from 296.2 K to 277.6 K which increases the turbine output by 12.8% during periods of high ambient temperature and improves yearly averaged power output by 5.5% in a temperature climate. It is shown that the energy in the turbine exhaust has the potential of producing additional cooling beyond that required to reduce the inlet temperature.« less
A study of poultry processing plant noise characteristics and potential noise control techniques
NASA Technical Reports Server (NTRS)
Wyvill, J. C.; Jape, A. D.; Moriarity, L. J.; Atkins, R. D.
1980-01-01
The noise environment in a typical poultry processing plant was characterized by developing noise contours for two representative plants: Central Soya of Athens, Inc., Athens, Georgia, and Tip Top Poultry, Inc., Marietta, Georgia. Contour information was restricted to the evisceration are of both plants because nearly 60 percent of all process employees are stationed in this area during a normal work shift. Both plant evisceration areas were composed of tile walls, sheet metal ceilings, and concrete floors. Processing was performed in an assembly-line fashion in which the birds travel through the area on overhead shackles while personnel remain at fixed stations. Processing machinery was present throughout the area. In general, the poultry processing noise problem is the result of loud sources and reflective surfaces. Within the evisceration area, it can be concluded that only a few major sources (lung guns, a chiller component, and hock cutters) are responsible for essentially all direct and reverberant sound pressure levels currently observed during normal operations. Consequently, any effort to reduce the noise problem must first address the sound power output of these sources and/or the absorptive qualitities of the room.
NASA Astrophysics Data System (ADS)
Bando, Shigeru; Watanabe, Hiroki; Asano, Hiroshi; Tsujita, Shinsuke
A methodology was developed to design the number and capacity for each piece of equipment (e.g. gas engines, batteries, thermal storage tanks) in microgrids with combined heat and power systems. We analyzed three types of microgrids; the first one consists of an office building and an apartment, the second one consists of a hospital and an apartment, the third one consists of a hotel, office and retails. In the methodology, annual cost is minimized by considering the partial load efficiency of a gas engine and its scale economy, and the optimal number and capacity of each piece of equipment and the annual operational schedule are determined by using the optimal planning method. Based on calculations using this design methodology, it is found that the optimal number of gas engines is determined by the ratio of bottom to peak of the electricity demand and the ratio of heat to electricity demand. The optimal capacity of a battery required to supply electricity for a limited time during a peak demand period is auxiliary. The thermal storage tank for space cooling and space heating is selected to minimize the use of auxiliary equipment such as a gas absorption chiller.
Sound attenuations of axial fan blade tones using flow-driven tunable resonator arrays
NASA Astrophysics Data System (ADS)
Gorny, Lee James
Flow-excited, tunable quarter-wavelength resonators can be integrated into the shrouds of ducted subsonic axial fans. This study explores their effectiveness in reducing propagations of tonal noise by means of acoustic wave cancellation. Resonators are a non-intrusive method of generating a secondary sound field near the plane of a rotor. As they can be strategically tuned to reduce radiated noise at the blade passage frequency (BPF) and its harmonics, resonators can be useful for a variety of applications to quiet existing and future turbomachinery. Experiments have demonstrated that a single quarter wave resonator is effective in reducing unidirectional plane wave propagations for long wavelength ducted applications while an array is effective for shorter wavelength or un-ducted facilities where shrouded fans are used. Testing conducted at Center for Acoustics and Vibrations (CAV) at the Pennsylvania State University the Deutsches Zentrum fur Luft und Raumfahrt (DLR) in Berlin, Germany demonstrated that resonator arrays were effective in attenuating shorter wavelength plane-wave and higher order modal propagations of blade tone noise. A chiller fan enclosure, constructed in the CAV laboratory emulated an industrial chiller in its operation. Using this facility, resonators were observed to attenuate blade tone noise from a non-ideal ducted geometry. The approaches used in this study evolved from Helmholtz resonators to conventional quarter wave tubes, to mouth tunable resonators, and finally to back-wall tunable resonators. These developments in tuning allowed for independent control of a resonator's magnitude and phase of the secondary sound field produced by the resonators. It was demonstrated that the use of two tunable resonator chambers oriented axially on either side of the blade region enables a dipole-like secondary sound field to be passively generated and bi-directional attenuations of plane wave noise to be achieved. Tonal attenuations of 28 dB were attained and BPF tones were reduced to less than 5 dB from the broadband noise floor for each case discussed above. In parallel with experimental work, analytical models were developed to effectively model and predict optimal resonator configurations for a given fan in operation. Interactions between resonators and the driving pressure field from the rotor blades are modeled using transmission line (TL) theory. Blade tone acoustic pressure is obtained using a finite element method (FEM) propagation code. By combining of these two methods, a resonator configuration that achieves optimal attenuation can be numerically obtained. The use of resonators has been shown to significantly attenuate fan noise in the conditions explored in the considered experiments. Numerical modeling has shown consistency in the response of flow driven resonators and their. These results indicate a strong potential for active control of fan noise using resonators and an approach to applying this control is presented.
NASA Astrophysics Data System (ADS)
Owens, F. J.
1990-12-01
Direct measurements of microwave absorption without use of rf H field modulation in granular composites of the 115 K superconductor Bi 2-XPb XSr 2Ca N-1Cu NO 4+2N as a function of magnetic field above 0.1 T reveal a continuing increase of absorption of microwave energy increasing magnetic field. The temperature and magnetic field dependence of the absorption are very different from the low magnetic field (<0.01 T) absorption arising from weak links in the material. The magnetic field and temperature dependence are consistent with the behavior of thermally activated flux flow resistance suggesting the absorption is due to flux creep.
Higher Education Facilities: The SmartGrid Earns a Doctorate in Economics
ERIC Educational Resources Information Center
Tysseling, John C.; Zibelman, Audrey; Freifeld, Allen
2011-01-01
Most higher education facilities have already accomplished some measure of a "microgrid" investment with building control systems (BCS), energy management systems (EMS), and advanced metering infrastructure (AMI) installations. Available energy production facilities may include boilers, chillers, cogeneration, thermal storage, electrical…
Energy Management: Money in the Bank.
ERIC Educational Resources Information Center
Have, Pete van der
2001-01-01
Discusses how the University of Utah developed a new chiller plant that could handle the existing and future loads of energy requirements while being totally financed via the implementation of energy saving retrofits, but not benefitting from the operations savings generated by their implementation. (GR)
Project W-320, tank 241-C-106 sluicing acceptance for beneficial use
DOE Office of Scientific and Technical Information (OSTI.GOV)
BAILEY, J.W.
The purpose of this document is to identify the Project W-320 Chiller Documentation required to be turned over from the Projects Organization to Tank Farm Operations as part of the acceptance of the new equipment for beneficial use.
Rothrock, M J; Locatelli, A; Glenn, T C; Thomas, J C; Caudill, A C; Kiepper, B H; Hiett, K L
2016-10-01
The commercial poultry processing environment plays a significant role in reducing foodborne pathogens and spoilage organisms from poultry products prior to being supplied to consumers. While understanding the microbiological quality of these products is essential, little is known about the microbiota of processing water tanks within the processing plant. Therefore, the goal of this study was to assess the microbiomes of the scalder and chiller tanks during a typical commercial processing d, and determine how bacterial populations, including foodborne pathogens and spoilage organisms, change during the processing day in relation to the bacterial communities as a whole. Additionally, considering this is the first microbiomic analysis of processing tank waters, 2 water sampling methods also were compared. Results of this study show that Proteobacteria and Firmicutes represented over half of the sequences recovered from both tanks at the phylum level, but the microbiomic profiles needed to be analyzed at the genus level to observe more dynamic population shifts. Bacteria known to predominate in the live production environment were found to increase in the scalder tank and gram negative spoilage-related bacteria were found to decrease in the chiller tank throughout the processing day. Directly sampling the scalder water, as compared to analyzing filtered samples, resulted in significantly different microbiomic profiles dominated by Anoxybacillus species. While no sequences related to major foodborne pathogens were found, further sampling collection and processing optimization should provide researchers and the poultry industry a new tool to understand the ecological role of spoilage and pathogenic bacteria within processing tank waters. Published by Oxford University Press on behalf of Poultry Science Association 2016. This work is written by (a) US Government employee(s) and is in the public domain in the US.
Survival of Listeria monocytogenes in a simulated recirculating brine chiller system.
Gailey, J K; Dickson, J S; Dorsa, W
2003-10-01
Contamination by Listeria monocytogenes of processed meats after cooking presents a significant food safety risk. The purpose of this study was to determine the survival of L. monocytogenes in a simulated recirculating brine chiller system using pH values of 5, 6, and 7 with free chlorine concentrations of 0, 3, 5, and 10 ppm in 20% salt brine at -12 degrees C. At pH values of 5, 6, and 7 with chlorine concentrations of 2 and 3 ppm, using 10(8) CFU in a test tube system, an immediate drop of 0.28 log CFU/ml with no significance between treatments (P > 0.05), followed by a steady survival phase with a slope close to 0, was observed. In brine at a pH of 5 with 5 and 10 ppm of chlorine, an initial drop of 0.8 log CFU/ml was observed, which was followed by a steady survival phase with a destruction slope close to zero. At an inoculation concentration of 10(2) CFU in a test tube system (pH values of 5 and 7 with 0 and 10 ppm of chlorine), the average initial drop for all treatments was 0.1 log CFU/ml, which was followed by a steady survival phase. In a recirculating system, very few cells were destroyed during the brine chilling process, but only low numbers of L. monocytogenes were recovered from the brine and uninoculated hot dogs. Although little destruction of L. monocytogenes was noted, the dilution effect observed during the study indicates that environmental contamination of a brine chiller system poses little danger of postcooking contamination for processed meats if the system is regularly cleaned and sanitized.
Analysis of electrical audit and energy efficiency in building Hotel BC, North Jakarta
NASA Astrophysics Data System (ADS)
Wahyudi Biantoro, Agung
2018-03-01
The Hotel BC is using power source from PLN with capacity of 4300 kVA which is divided into 3 units of 2000 kVA transformer. Transformers are used to supply the load of Mall tenants, and Utility loads, such as Chiller, pumps and others. Problems found in the field are complaints from the hotel regarding the safety of electrical installations and wasteful, inefficient electrical costs. The purpose of this study is to check the electrical installation in the building and determine the Energy Use Intensity (EUI) and the cost of payment according to usage based on historical data of the building then compare it with the EUI standard of Ministry of Energy and Mineral Resources of Indonesia. The method used is survey measurement method and quantitative descriptive analysis by comparing in general condition of energy consumption of this building with standard issued by Ministry of Energy and Mineral Resources of Indonesia. The EUI is average 645.58 kWh/m2/year, or 53.79 kWh/m2/month, this is inefficient category, because its EUI value is > 24 kWh / m2 / month. For Electrical audit on imaging thermal test at Panel Out Going of chiller pump, 200 ampere, the highest temperature is 97.3° C, at 200 ampere phase S termination, and this is included in the major category. The numbers of hot spots on the Capacitor bank panels are 10 major points and Chiller panel has 10 major. There are many major points and they are quite dangerous because they can cause fire hazard on the panel. The AC average temperature and humidity distribution did not meet the standard of SNI (Indonesia National Standard).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Malov, Aleksei N; Orishich, Anatolii M
Results of optimisation of repetitively pulsed CO{sub 2}-laser generation are presented for finding physical conditions of forming stable burning of an optical pulsed discharge (OPD) in a supersonic air flow and for studying the influence of pulse parameters on the energy absorption efficiency of laser radiation in plasma. The optical discharge in a supersonic air flow was formed by radiation of a repetitively pulsed CO{sub 2} laser with mechanical Q-switching excited by a discharge with a convective cooling of the working gas. For the first time the influence of radiation pulse parameters on the ignition conditions and stable burning ofmore » the OPD in a supersonic air flow was investigated and the efficiency of laser radiation absorption in plasma was studied. The influence of the air flow velocity on stability of plasma production was investigated. It was shown that stable burning of the OPD in a supersonic flow is realised at a high pulse repetition rate where the interval between radiation pulses is shorter than the time of plasma blowing-off. Study of the instantaneous value of the absorption coefficient shows that after a breakdown in a time lapse of 100 - 150 ns, a quasi-stationary 'absorption phase' is formed with the duration of {approx}1.5 ms, which exists independently of air flow and radiation pulse repetition rate. This phase of strong absorption is, seemingly, related to evolution of the ionisation wave. (laser applications and other topics in quantum electronics)« less
Counter flow cooling drier with integrated heat recovery
Shivvers, Steve D [Prole, IA
2009-08-18
A drier apparatus for removing water or other liquids from various materials includes a mixer, drying chamber, separator and regenerator and a method for use of the apparatus. The material to be dried is mixed with a heated media to form a mixture which then passes through the chamber. While passing through the chamber, a comparatively cool fluid is passed counter current through the mixture so that the mixture becomes cooler and drier and the fluid becomes hotter and more saturated with moisture. The mixture is then separated into drier material and media. The media is transferred to the regenerator and heated therein by the hot fluid from the chamber and supplemental heat is supplied to bring the media to a preselected temperature for mixing with the incoming material to be dried. In a closed loop embodiment of the apparatus, the fluid is also recycled from the regenerator to the chamber and a chiller is utilized to reduce the temperature of the fluid to a preselected temperature and dew point temperature.
49. Environmental equipment room, cbr filter at left, ventilation control ...
49. Environmental equipment room, cbr filter at left, ventilation control panel in center, brine chiller controls at right, looking southeast - Ellsworth Air Force Base, Delta Flight, Launch Control Facility, County Road CS23A, North of Exit 127, Interior, Jackson County, SD
NASA Technical Reports Server (NTRS)
Buist, R. J.
1977-01-01
The design and fabrication of a thermoelectric chiller for use in chilling a liquid reservoir is described. Acceptance test results establish the accuracy of the thermal model and predict the unit performance under various conditions required by the overall spacelab program.
20. Perimeter acquisition radar building room #105, shockisolated platform for ...
20. Perimeter acquisition radar building room #105, shock-isolated platform for chillers is easily seen on the right - Stanley R. Mickelsen Safeguard Complex, Perimeter Acquisition Radar Building, Limited Access Area, between Limited Access Patrol Road & Service Road A, Nekoma, Cavalier County, ND
Regenerator-based thermoacoustic refrigerator for ice cream storage applications
NASA Astrophysics Data System (ADS)
Poese, Matthew E.; Smith, Robert W. M.; Garrett, Steven L.
2003-10-01
A regenerator-based chiller has been built in the ``bellows bounce'' style [J. Acoust. Soc. Am. 112, 15 (2002)] to replace the vapor compression system in an ice cream sales cabinet. It utilizes a 6-in.-diam metal bellows to form a compliant cavity that contains the dynamic pressure oscillation (>50 kPa). The stiffness of the gas trapped in the bellows is resonated against the mass of the bellows-cap and the mass of a moving-magnet linear motor which is capable of high (>85%) electro-acoustic efficiency. A second resonator, operated well below its natural frequency, uses the gas stiffness of a 1-l volume nested within the bellows and the inertia of an ordinary loudspeaker cone to create the pressure difference across the regenerator that drives gas flow that is in-phase with pressure. The mass of the cone can be adjusted to vary the multiplication factor that is typically 5%-10% greater than the dynamic pressure within the bellows. The loudspeaker cone suffers none of the hydrodynamic losses associated with an acoustic inertance and eliminates problems with dc gas flow in the energy feedback path. The cold heat exchanger forms one surface of the pressure vessel permitting direct contact with any thermal load. [Work supported by Ben and Jerry's Homemade.
Ergot alkaloids reduce rumen epithelial blood flow and volatile fatty acid absorption
USDA-ARS?s Scientific Manuscript database
Ergot alkaloids have been shown to induce vasoconstriction of both peripheral and ruminal vessels. Constriction of ruminal vessels could lead to a reduction in epithelial blood flow thereby reducing nutrient absorption. The objectives of this experiment were to determine if steers receiving endophyt...
Real-time Data Center Energy Efficiency At Pacific Northwest National Laboratory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sisk, Daniel R.; Khaleel, Mohammad A.; Marquez, Andres
2009-05-26
The escalating consumption of power in data centers worldwide has brought the issue of data center energy efficiency to the forefront. Data center owners and operators now regard detailed knowledge of the energy efficiencies of their data centers as a competitive advantage. With funding from the Department of Energy (NNSA), PNNL has undertaken an in-depth analysis of the real-time energy efficiency for its Energy Smart Data Center Test Bed(ESDC-TB), which is housed in the mixed-use EMSL. The analysis is centered around the real-time display of The Green Grid’s proposed DCiE metric. To calculate this metric, PNNL relies on a varietymore » of sources of data. At the ESDC-TB level, the data center is instrumented to the 100% level (all power consumption, and water temperatures and flow rates are measured). Most of this data is monitored in real-time, but the exception to this is with the CRAHs, which rely on a one-time power consumption measurement for the blowers (these are single speed blowers, so a one-time measurement suffices.). Outside of the data center (EMSL facility level), PNNL relies on the following: • Real-time data from the entire chiller plant (five chillers), six chilled water pumps, and one of four cooling towers (blowers only). • One-time power measurements for a single fixed speed pump that is representative of each grouping of pumps (the other pumps are assumed to possess the same power consumption levels). • One-time power measurements for a single two-speed cooling tower blower. This same blower model is deployed in three of the four cooling towers, so is assumed to be representative for all these blowers. • One-time power measurements for a single fixed speed cooling tower pump. This same pump model is deployed in all four cooling towers, so is assumed to be representative for all these pumps. A software tool named FRED was developed by PNNL to acquire, reduce, display, and archive all the data acquired from the ESDC-TB and EMSL. FRED provides the ability to display various levels of real-time data starting at the ESDC-TB and EMSL levels, then to lower levels as desired. For example, for the ESDC-TB, graphical screens are provided at the data center level, the rack level, the server level, and even the component level. In the near-term, FRED will also display the real-time DCiE. One of the major challenges to doing this in a mixed-use facility has been to quantify the power consumption of each major mechanical or electrical subsystem that is attributable to the IT equipment housed within the ESDC-TB (i.e., NW-ICE). PNNL has tackled this issue for its five chiller plant, and the analysis is presented in the paper. The analysis for all the remaining mechanical and electrical subsystems is now underway and will be presented in future publications.« less
Nonintrusive fast response oxygen monitoring system for high temperature flows
NASA Technical Reports Server (NTRS)
Oh, Daniel B.; Stanton, Alan C.
1993-01-01
A new technique has been developed for nonintrusive in situ measurement of oxygen concentration, gas temperature, and flow velocity of the test media in hypersonic wind tunnels. It is based on absorption of near-infrared radiation from inexpensive GaAlAs laser diodes used in optoelectronics industry. It is designed for simultaneous measurements along multiple lines of sight accessed by fiber optics. Molecular oxygen concentration is measured from the magnitude of absorption signals; rotational gas temperature is measured from the intensity ratio of two oxygen absorption lines; and the flow velocity is measured from the Doppler shift of the absorption line positions. This report describes the results of an extensive series of tests of the prototype instrument in laboratory flames emphasizing assessment of the instruments capabilities for quantitative measurement of O2 concentration (mole fraction) and gas temperature.
Stretching Energy Dollars for Healthy Schools
ERIC Educational Resources Information Center
Angerame, Timothy
2011-01-01
When financial savings are critical to every institution, facility managers demand even more from their energy systems while looking to spend less. One way to achieve significant energy savings and healthy schools without making a substantial capital investment is through energy monitoring and chiller plant optimization. The greatest energy…
HEAT TRANSFER EVALUATION OF HFC-236FA IN CONDENSATION AND EVAPORATION
The report gives results of an evaluation of the shell-side heat transfer performance of hydrofluorocarbon (HFC)-236fa, which is considered to be a potential substitute for chlorofluorocarbon (CFC)-114 in Navy shipboard chillers, for both conventional finned [1024- and 1575-fpm (...
Microbial contamination in poultry chillers estimated by Monte Carlo simulations
USDA-ARS?s Scientific Manuscript database
Recent bacterial outbreaks in fresh and processed foods have increased awareness of food safety among consumers, regulatory agencies, and the food industry. The risk of contamination exists in meat processing facilities where bacteria that are normally associated with the animal are transferred to t...
Sound Absorption of a 2DOF Resonant Liner with Negative Bias Flow
NASA Technical Reports Server (NTRS)
Ahuja, K. K.; Cataldi, P.; Gaeta, R. J., Jr.
2000-01-01
This report describes an experimental study conducted to determine the effect of negative bias flow on the sound absorption of a two degree-of-freedom liner. The backwall for the liner was designed to act as a double-Helmholtz resonator so as to act as a hard wall at all frequencies except at its resonant frequencies. The effect of bias flow is investigated for a buried septum porosity of 2% and 19.5% for bias flow orifice Mach numbers up to 0.311. The bias flow appears to modify the resistance and reactance of the backwall alone at lower frequencies up to about 2 kHz, with marginal effects at higher frequencies. Absorption coefficients close to unity are achieved for a frequency range of 500 - 4000 Hz for the overall liner for a septum porosity of 2% and orifice Mach number of 0.128. Insertion loss tests performed in a flow duct facility for grazing flow Mach numbers up to 0.2 and septum Mach numbers up to 0.15 showed that negative bias flow can increase insertion loss by as much as 10 dB at frequencies in the range of 500 D 1400 Hz compared to no grazing flow. The effectiveness of the negative bias flow is diminished as the grazing flow velocity is increased.
Shachar-Hill, B; Hill, A E
1993-01-01
1. Bidirectional paracellular fluxes using radioactive dextrans as inert molecular probes have been measured across Necturus gall-bladder epithelium during conditions of normal fluid absorption. There is a net flux at all radii analysed (0.4-2.2 nm) in the direction of fluid absorption. 2. The net flux is substantial at all radii within the range. The data extraplate to 2 x 10(-6) cm s-1 at zero probe radius, which is very close to the rate of epithelial fluid absorption. 3. The unstirred layers at the epithelial faces during transport have been determined; their contribution to the net fluxes is negligible. 4. Two possible mechanisms for the net flow of probes are considered: (i) that the probes diffuse across the junctions and are then entrained in a local osmotic flow along the interspaces and subepithelium; (ii) that the probes are entrained in volume flow across the junctions and the emergent solution subsequently passes through the interspaces and subepithelium. Model calculations clearly rule out mechanism (i) in which the maximum net flow obtainable is less than 10% of that observed. In addition the presence of leak paths shunting the junctions is not compatible with the observed fluxes. With mechanism (ii) the net flows are correctly predicted with all the fluid flow being transjunctional. The fluid absorption is therefore entirely paracellular. 5. The slope of the net flow curve shows no apparent change in magnitude over the range of the probe radii, indicating that effectively only one population of convective channels is present with parallel walls separated by about 7.7 nm. This agrees with the width previously determined by electron microscopy. 6. If the fluid absorption is junctional then the cellular route offers little if any relative contribution. The hydraulic conductivity of the junctions is not high enough, or the osmotic permeability of the membranes low enough, to accommodate this by osmosis and therefore the junctional fluid absorption must be non-osmotic. Images Fig. 1 Fig. 4 PMID:7504731
Computed tomography measurement of gaseous fuel concentration by infrared laser light absorption
NASA Astrophysics Data System (ADS)
Kawazoe, Hiromitsu; Inagaki, Kazuhisa; Emi, Y.; Yoshino, Fumio
1997-11-01
A system to measure gaseous hydrocarbon distributions was devised, which is based on IR light absorption by C-H stretch mode of vibration and computed tomography method. It is called IR-CT method in the paper. Affection of laser light power fluctuation was diminished by monitoring source light intensity by the second IR light detector. Calibration test for methane fuel was carried out to convert spatial data of line absorption coefficient into quantitative methane concentration. This system was applied to three flow fields. The first is methane flow with lifted flame which is generated by a gourd-shaped fuel nozzle. Feasibility of the IR-CT method was confirmed through the measurement. The second application is combustion field with diffusion flame. Calibration to determine absorptivity was undertaken, and measured line absorption coefficient was converted spatial fuel concentration using corresponding temperature data. The last case is modeled in cylinder gas flow of internal combustion engine, where gaseous methane was led to the intake valve in steady flow state. The fuel gas flow simulates behavior of gaseous gasoline which is evaporated at intake valve tulip. Computed tomography measurement of inner flow is essentially difficult because of existence of surrounding wall. In this experiment, IR laser beam was led to planed portion by IR light fiber. It is found that fuel convection by airflow takes great part in air-fuel mixture formation and the developed IR-CT system to measure fuel concentration is useful to analyze air-fuel mixture formation process and to develop new combustors.
Ideas that Work!. Retuning the Building Automation System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parker, Steven
A building automation system (BAS) can save considerable energy by effectively and efficiently operating building energy systems (fans, pumps, chillers boilers, etc.), but only when the BAS is properly set up and operated. Tuning, or retuning, the BAS is a cost effective process worthy of your time and attention.
9 CFR 441.10 - Retained water.
Code of Federal Regulations, 2014 CFR
2014-01-01
... standard for Salmonella as set forth in the PR/HACCP regulations (9 CFR 310.25(b), 381.94(b)) and the time... chillers in a series and arrangements of chilling system components, and the number of evisceration lines... equipment used should be accurately described. Any mechanical or design changes made to the chilling...
USDA-ARS?s Scientific Manuscript database
The commercial poultry processing environment plays a significant role in reducing foodborne pathogens and spoilage organisms from poultry products prior to being supplied to consumers. While understanding the microbiological quality of these products is essential, little is known about the microbi...
The report gives results of an evaluation of the heat transfer performance of pure hydrofluorocarbon (HFC)-236ea for high performance enhanced tubes which had not been previously used in Navy shipboard chillers. Shell-side heat transfer coefficient data are presented for condensa...
NEW CHEMICAL ALTERNATIVE FOR OZONE-DEPLETING SUBSTANCES: HFC-236FA
The report gives results of a preliminary evaluation of a new hydrofluorocarbon (HFC)--HFC-236fa or 1,1,1,3,3,3-hexafluoropropane--as a possible alternative for chlorofluorocarbon (CFC)-114 (1,2-dichloro-1,1,2,2-tetrafluoroethane) refrigerant for chillers and as a possible fire s...
NEW CHEMICAL ALTERNATIVE FOR OZONE-DEPLETING SUBSTANCES: HFC-236EA
The report gives results of a preliminary evaluation of a new hydrofluorocarbon (HFC-236ea or 1, 1, 1, 2, 3, 3-hexafluoropropane) as a possible alternative for chlorofluorocarbon (CFC)-114 (1, 2-dichloro-1, 1, 2, 2-tetrafluoroethane) refrigerant in chillers and high-temperature i...
Energy Systems Integration News | Energy Systems Integration Facility |
for its novel approach to energy reduction. The ultra-efficient ESIF data center features a chiller "chips to bricks" approach to sustainability integrates the data center into the facility systems, rather than trying to optimize each in isolation. Key to the approach was collaboration with
USDA-ARS?s Scientific Manuscript database
Catfish skins, intestines, fresh fillets, processing surfaces at different production stages, chiller water and non-food contact surfaces were sampled for Listeria monocytogenes and other Listeria species. Among 315 samples, prevalence of L. monocytogenes, Listeria innocua and a group of Listeria se...
Ice Storage System for School Complex.
ERIC Educational Resources Information Center
Montgomery, Ross D.
1998-01-01
Describes a project at the Manatee Education Center in Naples, Florida, which won an ASHRAE award. Project involved the implementation of ice-storage technology in 19 schools. Compares the performance of ice-storage systems with traditional chiller designs in two other schools. Tables illustrate costs for the campuses. Addresses the maintenance…
The shelf life of chilled sheep livers packed in closed tubs.
Gill, C O; Penny, N
1984-01-01
Livers incubated at 30°C in closed tubs developed floras dominated by Enterobacteriaceae. At chiller temperatures, floras were ultimately dominated by psychrotrophic lactobacilli. Tub-packed livers can have an extended shelf life similar to that reported for vacuum-packed liver. Copyright © 1984. Published by Elsevier Ltd.
Scalability study of solid xenon
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yoo, J.; Cease, H.; Jaskierny, W. F.
2015-04-01
We report a demonstration of the scalability of optically transparent xenon in the solid phase for use as a particle detector above a kilogram scale. We employed a cryostat cooled by liquid nitrogen combined with a xenon purification and chiller system. A modified {\\it Bridgeman's technique} reproduces a large scale optically transparent solid xenon.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saripalli, Prasad; Brown, Christopher F.; Lindberg, Michael J.
We report on a new Cellular Absorptive Tracers (CATs) method, for a simple, non-destructive characterization of bacterial mass in flow systems. Results show that adsorption of a CAT molecule into the cellular mass results in its retardation during flow, which is a good, quantitative measure of the biomass quantity and distribution. No such methods are currently available for a quantitative characterization of cell mass.
Shehzad, Sabir Ali; Alsaedi, Ahmed; Hayat, Tasawar; Alhuthali, M. Shahab
2013-01-01
This paper looks at the series solutions of three dimensional boundary layer flow. An Oldroyd-B fluid with variable thermal conductivity is considered. The flow is induced due to stretching of a surface. Analysis has been carried out in the presence of heat generation/absorption. Homotopy analysis is implemented in developing the series solutions to the governing flow and energy equations. Graphs are presented and discussed for various parameters of interest. Comparison of present study with the existing limiting solution is shown and examined. PMID:24223780
NASA Technical Reports Server (NTRS)
Zimmermann, M.
1980-01-01
A technique is presented for visualizing and quantitatively measuring velocity, temperature, and pressure by shining a single frequency laser beam into a gaseous flow which is seeded with an atomic species. The laser is tuned through the absorption frequencies of the seeded species and the absorption profile is detected by observing fluorescence as the atoms relax back to the ground state. The flow velocity is determined by observing the Doppler shift in the absorption frequency. Spectroscopic absorption line broadening mechanisms furnish information regarding the static temperature and pressure of the moving gas. Results of experiments conducted in the free stream and in the bow shock of a conical model mounted in a hypersonic wind tunnel indicate that the experimental uncertainties in the measurement of average values for the velocity, temperature and pressure of the flow are 0.1, 5 and 10 percent respectively.
Contaminant transport from point source on water surface in open channel flow with bed absorption
NASA Astrophysics Data System (ADS)
Guo, Jinlan; Wu, Xudong; Jiang, Weiquan; Chen, Guoqian
2018-06-01
Studying solute dispersion in channel flows is of significance for environmental and industrial applications. Two-dimensional concentration distribution for a most typical case of a point source release on the free water surface in a channel flow with bed absorption is presented by means of Chatwin's long-time asymptotic technique. Five basic characteristics of Taylor dispersion and vertical mean concentration distribution with skewness and kurtosis modifications are also analyzed. The results reveal that bed absorption affects both the longitudinal and vertical concentration distributions and causes the contaminant cloud to concentrate in the upper layer. Additionally, the cross-sectional concentration distribution shows an asymptotic Gaussian distribution at large time which is unaffected by the bed absorption. The vertical concentration distribution is found to be nonuniform even at large time. The obtained results are essential for practical implements with strict environmental standards.
Supersonic Mass Flux Measurements via Tunable Diode Laser Absorption and Non-Uniform Flow Modeling
NASA Technical Reports Server (NTRS)
Chang, Leyen S.; Strand, Christopher L.; Jeffries, Jay B.; Hanson, Ronald K.; Diskin, Glenn S.; Gaffney, Richard L.; Capriotti, Diego P.
2011-01-01
Measurements of mass flux are obtained in a vitiated supersonic ground test facility using a sensor based on line-of-sight (LOS) diode laser absorption of water vapor. Mass flux is determined from the product of measured velocity and density. The relative Doppler shift of an absorption transition for beams directed upstream and downstream in the flow is used to measure velocity. Temperature is determined from the ratio of absorption signals of two transitions (lambda(sub 1)=1349 nm and lambda(sub 2)=1341.5 nm) and is coupled with a facility pressure measurement to obtain density. The sensor exploits wavelength-modulation spectroscopy with second-harmonic detection (WMS-2f) for large signal-to-noise ratios and normalization with the 1f signal for rejection of non-absorption related transmission fluctuations. The sensor line-of-sight is translated both vertically and horizontally across the test section for spatially-resolved measurements. Time-resolved measurements of mass flux are used to assess the stability of flow conditions produced by the facility. Measurements of mass flux are within 1.5% of the value obtained using a facility predictive code. The distortion of the WMS lineshape caused by boundary layers along the laser line-of-sight is examined and the subsequent effect on the measured velocity is discussed. A method for correcting measured velocities for flow non-uniformities is introduced and application of this correction brings measured velocities within 4 m/s of the predicted value in a 1630 m/s flow.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kirpich, A.S.
1979-12-01
The General Electric/Sea World Photovoltaic Concentrator Application Experiment will be located at Sea World's Marine Park near Orlando, Florida. The experiment will consist of nine azimuth-tracking turntable arrays, each containing twenty-four elevation-tracking parabolic trough PV concentrators of a type developed on this contract. The system will produce a peak power output of 330 kW and an annual net electrical energy of 355 MWh corresponding to an annual direct normal insolation of 1375.5 kWh/m/sup 2/. A line-commutated DC/AC inverter controlled to operate at the solar array maximum power point will deliver three-phase power through a bidirectional transformer to a 13-kilovolt linemore » serving the Sea World Park. In addition to generating electrical power, the system will produce 3.56 x 10/sup 5/ ton-hours of cooling for air conditioning a nearby shark exhibit by supplying collected thermal energy to a lithium-bromide absorption chiller. With credit included for the amount of electricity that would be required to produce this cooling by a vapor compression cycle, the overall system efficiency is estimated to be 11.7 percent.« less
Sim, Jennifer A; Horowitz, M; Summers, M J; Trahair, L G; Goud, R S; Zaknic, A V; Hausken, T; Fraser, J D; Chapman, M J; Jones, K L; Deane, A M
2013-02-01
To compare nutrient-stimulated changes in superior mesenteric artery (SMA) blood flow, glucose absorption and glycaemia in individuals older than 65 years with, and without, critical illness. Following a 1-h 'observation' period (t (0)-t (60)), 0.9 % saline and glucose (1 kcal/ml) were infused directly into the small intestine at 2 ml/min between t (60)-t (120), and t (120)-t (180), respectively. SMA blood flow was measured using Doppler ultrasonography at t (60) (fasting), t (90) and t (150) and is presented as raw values and nutrient-stimulated increment from baseline (Δ). Glucose absorption was evaluated using serum 3-O-methylglucose (3-OMG) concentrations during, and for 1 h after, the glucose infusion (i.e. t (120)-t (180) and t (120)-t (240)). Mean arterial pressure was recorded between t (60)-t (240). Data are presented as median (25th, 75th percentile). Eleven mechanically ventilated critically ill patients [age 75 (69, 79) years] and nine healthy volunteers [70 (68, 77) years] were studied. The magnitude of the nutrient-stimulated increase in SMA flow was markedly less in the critically ill when compared with healthy subjects [Δt (150): patients 115 (-138, 367) versus health 836 (618, 1,054) ml/min; P = 0.001]. In patients, glucose absorption was reduced during, and for 1 h after, the glucose infusion when compared with health [AUC(120-180): 4.571 (2.591, 6.551) versus 11.307 (8.447, 14.167) mmol/l min; P < 0.001 and AUC(120-240): 26.5 (17.7, 35.3) versus 40.6 (31.7, 49.4) mmol/l min; P = 0.031]. A close relationship between the nutrient-stimulated increment in SMA flow and glucose absorption was evident (3-OMG AUC(120-180) and ∆SMA flow at t (150): r (2) = 0.29; P < 0.05). In critically ill patients aged >65 years, stimulation of SMA flow by small intestinal glucose infusion may be attenuated, which could account for the reduction in glucose absorption.
Influences of the Ratio of Polyol and MDI on the Acoustic Parameters of Polyurethane
NASA Astrophysics Data System (ADS)
Wang, Yonghua; Liu, Zheming; Wu, Haiquan; Zhang, Chengchun; Yu, Huadong; Ren, Luquan; Ichchou, Mohamed
2018-05-01
In this paper, the influence of different ratio of polyol and MDI on the absorption coefficient and acoustic parameters of polyurethane was studied. Ratio of 100:40 and 100:45 show the best sound absorption performance, and the change trend of transmission loss and sound absorption coefficient are opposite. The flow resistance increased with the increasing of the ratio of polyol and MDI, the greater the flow resistance, the worse the high frequency sound absorption property of the polyurethane. When the ratio of polyol and MDI keep 100:45, the minimum porosity of sample, the polyurethane porosity increase with the ratio of polyol and MDI increase.
NASA Astrophysics Data System (ADS)
Mohamed, Muhammad Khairul Anuar; Noar, Nor Aida Zuraimi Md; Ismail, Zulkhibri; Kasim, Abdul Rahman Mohd; Sarif, Norhafizah Md; Salleh, Mohd Zuki; Ishak, Anuar
2017-08-01
Present study solved numerically the velocity slip effect on stagnation point flow past a stretching surface with the presence of heat generation/absorption and Newtonian heating. The governing equations which in the form of partial differential equations are transformed to ordinary differential equations before being solved numerically using the Runge-Kutta-Fehlberg method in MAPLE. The numerical solution is obtained for the surface temperature, heat transfer coefficient, reduced skin friction coefficient as well as the temperature and velocity profiles. The flow features and the heat transfer characteristic for the pertinent parameter such as Prandtl number, stretching parameter, heat generation/absorption parameter, velocity slip parameter and conjugate parameter are analyzed and discussed.
MODELING AND DESIGN STUDY USING HFC-236EA AS AN ALTERNATIVE REFRIGERANT IN A CENTRIFUGAL COMPRESSOR
The report gives results of an investigation of the operation of a centrifugal compressor--part of a chlorofluorocarbon (CFC)-114 chiller installation--with the new refrigerant hydrofluorocarbon (HFC)-236ea, a proposed alternative to CFC-114. A large set of CFC-236ea operating da...
The paper discusses simulation of the performance of chlorine-free fluorinated ethers and fluorinated hydrocarbons as potential long-term replacements for CFC-11 and -114. Modeling has been done with in-house refrigeration models based on the Carnahan-Starling-DeSantis Equation o...
The CFC challenge: chillers to replace, retrofit or ?
Anderson, W D
1995-01-01
Health care facilities are planning for changes in regulations regarding chlorofluorocarbon-based refrigerants. These changes are imminent, leaving little time to figure out what to do with equipment using these refrigerants. This article looks at the background of the CFC phaseout program and reviews options available to engineers in assessing their equipment.
NCI at Frederick's Wye Oak Moves Down the Street | Poster
One of NCI at Frederick’s two offspring of the Wye Oak tree that lived for nearly 500 years in Talbot County, Maryland, has found a new home on campus. The move was necessitated by upgrades to Chiller Plant #5 and the associated water piping routes on the west side of building 560.
41 CFR 102-41.210 - What are some examples of drug paraphernalia?
Code of Federal Regulations, 2013 CFR
2013-07-01
... pipes; (c) Carburetion tubes and devices; (d) Smoking and carburetion masks; (e) Roach clips (objects used to hold burning material, such as a marijuana cigarette, that has become too small or too short to...; (l) Bongs; (m) Ice pipes or chillers; (n) Wired cigarette papers; or (o) Cocaine freebase kits. ...
41 CFR 102-41.210 - What are some examples of drug paraphernalia?
Code of Federal Regulations, 2012 CFR
2012-01-01
... pipes; (c) Carburetion tubes and devices; (d) Smoking and carburetion masks; (e) Roach clips (objects used to hold burning material, such as a marijuana cigarette, that has become too small or too short to...; (l) Bongs; (m) Ice pipes or chillers; (n) Wired cigarette papers; or (o) Cocaine freebase kits. ...
41 CFR 102-41.210 - What are some examples of drug paraphernalia?
Code of Federal Regulations, 2014 CFR
2014-01-01
... pipes; (c) Carburetion tubes and devices; (d) Smoking and carburetion masks; (e) Roach clips (objects used to hold burning material, such as a marijuana cigarette, that has become too small or too short to...; (l) Bongs; (m) Ice pipes or chillers; (n) Wired cigarette papers; or (o) Cocaine freebase kits. ...
Credit PSR. Interior view shows the building equipment room as ...
Credit PSR. Interior view shows the building equipment room as seen looking south southwest (206°) from the doorway. The control console contains switches for chiller pumps, fans, heaters, temperature controls, and alarms - Jet Propulsion Laboratory Edwards Facility, Solid Propellant Conditioning Building, Edwards Air Force Base, Boron, Kern County, CA
High-temperature tenderizing of beef sides: bacterial considerations.
Wilhelm, K E; Marsh, B B; Lochner, J V
1982-01-01
A microbiological study of an experimental beef-tenderizing treatment, in which lean sides are held at 37 degrees C until transfer to a chiller at 3 h postmortem, was made. The treatment did not cause a significant increase in bacterial numbers or a proliferation of potential pathogens or food-spoiling organisms. PMID:7181504
2008-04-01
soil testing labs, farming cooperatives, flood protection walls, veterinary services, solar meat chillers, poultry industry development, fish farms...measuring a PRT’s performance or effectiveness. Many of our sources observed that PRT operations have been and continue to be a “pick up game
Uma, Kasimayan; Pan, Guan-Ting; Yang, Thomas C-K
2017-06-02
Abst r act: Metal organic framework (MOF) of MIL-101(Cr)-Silica (SiO₂) composites with highly mesoporous and uniform dispersions were synthesized by a microwave-assisted hydrothermal method followed by the sol-gel technique. Water vapor adsorption experiments were conducted on the MIL-101(Cr)-SiO₂ composites for industrial adsorption chiller applications. The effects of MIL-101(Cr)-SiO₂ mixing ratios (ranging from 0% to 52%), the surface area and amount of Lewis and Brønsted sites were comprehensively determined through water vapor adsorption experiments and the adsorption mechanism is also explained. The BET and Langmuir results indicate that the adsorption isotherms associated with the various MIL-101(Cr)-SiO₂ ratios demonstrated Type I and IV adsorption behavior, due to the mesoporous structure of the MIL-101(Cr)-SiO₂. It was observed that the increase in the amount of Lewis and Brønsted sites on the MIL-101(Cr)-SiO₂ composites significantly improves the water vapor adsorption efficiency, for greater stability during the water vapor adsorption experiments.
Toyofuku, Chiharu; Alam, Md Shahin; Yamada, Masashi; Komura, Miyuki; Suzuki, Mayuko; Hakim, Hakimullah; Sangsriratanakul, Natthanan; Shoham, Dany; Takehara, Kazuaki
2017-06-16
An alkaline agent, namely food additive grade calcium hydroxide (FdCa(OH) 2 ) in solution at 0.17%, was evaluated for its bactericidal efficacies in chiller water with sodium hypochlorite (NaOCl) at a concentration of 200 ppm total residual chlorine. Without organic material presence, NaOCl could inactivate Salmonella Infantis and Escherichia coli within 5 sec, but in the presence of fetal bovine serum (FBS) at 0.5%, the bactericidal effects of NaOCl were diminished completely. FdCa(OH) 2 solution required 3 min to inactivate bacteria with or without 5% FBS. When NaOCl and FdCa(OH) 2 were mixed at the final concentration of 200 ppm and 0.17%, respectively, the mixed solution could inactivate bacteria at acceptable level (10 3 reduction of bacterial titer) within 30 sec in the presence of 0.5% FBS. The mixed solution also inhibited cross-contamination with S. Infantis or E. coli on chicken meats. It was confirmed and elucidated that FdCa(OH) 2 has a synergistic effect together with NaOCl for inactivating microorganisms.
NASA Astrophysics Data System (ADS)
Winterleitner, Gerd; Schütz, Felina; Huenges, Ernst
2017-04-01
A collaborative research programme between the German Research Centre for Geoscience, Potsdam (GFZ) and The Research Council of Oman (TRC) is underway, which aims to develop and implement an innovative concept of a sustainable thermally driven cooling system in combination with a HT-ATES in northern Oman. The system will use an absorption chiller for cold supply, which nominally requires water of around 100°C as energy source. Solar collectors will provide this thermal energy and energy surpluses during daytimes will be stored to ensure a continuous operation of the cooling system. An integral part of this project is, therefore, the development of an efficient HT-ATES (100°C), which is based on temporary storage and recovery of thermal energy through hot water injection in subsurface aquifer horizons. Thus, an accurate thermal and fluid flow characterisation of potential reservoir horizons is essential to ensure optimal efficiency of the cooling system. The study area is located in the Al Khwad area, approximately 40 km to the west of Muscat. The area is characterised by a thick Cenozoic mixed carbonate-siliciclastic sedimentary succession, containing at least 3 aquifer horizons. We use a multidisciplinary approach for the initial ATES exploration and development phase, including traditional geological fieldwork dovetailed with virtual outcrop geology, thin-section analyses, geological modelling and reservoir fluid flow forecasting analyses. Our first results indicate two potential storage horizons: (1) a Miocene-aged clastic-dominated alluvial fan system and (2) an Eocene carbonate-dominated sequence. The alluvial fan system is characterised by a more than 300 m thick, coarse-clastic succession of coalesced individual fans. Thermal and hydraulic parameters are favourable for gravel and sandstone intervals but reservoir architecture is complex due to multiple generations of interconnecting fans with highly heterogeneous facies distributions. The Eocene carbonates, as second potential storage horizon, were deposited in a carbonate ramp setting. Individual facies belts extend over kilometres and thus horizontal reservoir connectivity is expected to be good with minor facies variability. Thin-section analyses point to the fossil-rich sections with high porosities and permeabilities and thus good storage qualities. Fluid flow and thermal modelling indicate that both potential storage horizons show good to very good storage characteristics but also have challenges such as reservoir heterogeneity and connectivity. In particular the tilting of the thermocline, specific to high-temperature systems poses a major challenge. We investigated scenarios to counterbalance the distortion of the subsurface heat-plume, which includes adjustments of the salinity contrast between injected and aquifer fluid to prohibit buoyancy-driven flow. Additionally, geological structures ("HT-ATES traps" e.g.: fault structures) were modelled in detail in order to analyse their suitability as high-temperature storage system. First results show that an effective HT-ATES trap is necessary in the alluvial fan system in order to keep in control of the heat-plume. Salinity adjustments are sufficient in the carbonate-dominated sequences where vertical permeability contrasts are higher and constitute natural vertical flow barriers.
Ultrasonically Encoded Photoacoustic Flowgraphy in Biological Tissue
NASA Astrophysics Data System (ADS)
Wang, Lidai; Xia, Jun; Yao, Junjie; Maslov, Konstantin I.; Wang, Lihong V.
2013-11-01
Blood flow speed is an important functional parameter. Doppler ultrasound flowmetry lacks sufficient sensitivity to slow blood flow (several to tens of millimeters per second) in deep tissue. To address this challenge, we developed ultrasonically encoded photoacoustic flowgraphy combining ultrasonic thermal tagging with photoacoustic imaging. Focused ultrasound generates a confined heat source in acoustically absorptive fluid. Thermal waves propagate with the flow and are directly visualized in pseudo color using photoacoustic computed tomography. The Doppler shift is employed to calculate the flow speed. This method requires only acoustic and optical absorption, and thus is applicable to continuous fluid. A blood flow speed as low as 0.24mm·s-1 was successfully measured. Deep blood flow imaging was experimentally demonstrated under 5-mm-thick chicken breast tissue.
Dynamics of water absorption through superabsorbent polymer
NASA Astrophysics Data System (ADS)
Chang, Sooyoung; Kim, Wonjung
2017-11-01
Superabsorbent polymers (SAPs) consist of hydrophilic cross-linked polymer networks that can absorb and retain a great amount of water relative to their own mass, so that they are widely used for disposable diapers and holding soil moisture in agriculture. SAPs are typically available in the form of submillimeter-sized particles, and the water absorption is driven by capillary flows between particles as well as diffusion that entail swelling. Although the control of water absorption of SAPs is important in engineering applications, but the dynamics of water absorption in SAP particles has not been fully understood. We examine the dynamics of the water absorption of sodium polyacrylate, one of the most common SAP. We experimentally measured the water absorption of sodium polyacrylate particles in one-dimensional confined channel. The water flows through the particles were analyzed by capillarity dominant at the early stage and by diffusion involving volume expansion critical at a later stage. The results provide a quantitative basis of the hydrodynamic analysis of the water flow through SAP particles from a macroscopic point of view, facilitating the prediction of water uptake of SAPs in hygienic and agricultural applications. This work was supported by the National Research Foundation of Korea (NRF) Grant funded by the Korea government (MSIP) (No.2015R1A2A2A04006181).
Contaminant transport in wetland flows with bulk degradation and bed absorption
NASA Astrophysics Data System (ADS)
Wang, Ping; Chen, G. Q.
2017-09-01
Ecological degradation and absorption are ubiquitous and exert considerable influence on the contaminant transport in natural and constructed wetland flows. It creates an increased demand on models to accurately characterize the spatial concentration distribution of the transport process. This work extends a method of spatial concentration moments by considering the non-uniform longitudinal solute displacements along the vertical direction, and analytically determines the spatial concentration distribution in the very initial stage since source release with effects of bulk degradation and bed absorption. The present method is demonstrated to bear a more accurate prediction especially in the initial stage through convergence analysis of Hermite polynomials. Results reveal that contaminant cloud shows to be more contracted and reformed by bed absorption with increasing damping factor of wetland flows. Tremendous vertical concentration variation especially in the downstream of the contaminant cloud remains great even at asymptotic large times. Spatial concentration evolution by the extended method other than the mean by previous studies is potential for various implements associated with contaminant transport with strict environmental standards.
Sound Absorption of a 2DOF Resonant Liner with Negative Bias Flow
NASA Technical Reports Server (NTRS)
Ahuja, K. K.; Cataldi, P.; Gaeta, R. J., Jr.; Jones, Mike (Technical Monitor)
2000-01-01
This report describes an experimental study conducted to determine the effect of negative bias flow on the sound absorption of a two degree-of-freedom liner. The backwall for the liner was designed to act as a double-Helmholtz resonator so as to act as a hard wall at all frequencies except at its resonant frequencies. All normal incident impedance data presented herein was acquired in an impedance tube. The effect of bias flow is investigated for a buried septum porosity of 2% and 19.5% for bias flow orifice mach numbers up to 03 11. As a porous backwall is needed for the flow to pass through, the effect of bias flow on this backwall all had to be evaluated first. The bias flow appears to modify the resistance and reactance of the backwall alone at lower frequencies up to about 2 kHz, with marginal effects at higher frequencies. Absorption coefficients close to unity are achieved for a frequency range of 500-4000 Hz for the overall liner for a septum porosity of 2% and orifice mach number of 0.128. Insertion loss tests performed in a flow duct facility for grazing flow Mach numbers up to 0.2 and septum mach numbers up to 0.15 showed that negative bias flow can increase insertion loss by as much as 10 dB at frequencies in the range of 500 - 1400 Hz compared to no grazing flow. The effectiveness of the negative bias flow is diminished as the grazing flow velocity is increased.
Ma, Liang; Zhao, Zhi-Huang; Peng, Lv; Yang, Xue-Jing; Fu, Peng-Bo; Liu, Yi; Huang, Yuan
2018-05-31
In this experiment, with stainless steel gas cyclone-liquid jet absorption separator as carrier, NH 3 as experimental gas, and water and H 3 PO 4 solution as absorbents, corresponding NH 3 absorption rate change is obtained through the adjustment of experimental parameters, such as NH 3 inlet concentration, inlet velocity of mixed gas, injection flow rate of absorbent, temperature of absorbent, and H 3 PO 4 absorbent concentration. The NH 3 absorption rate decreases with the increase in NH 3 inlet concentration and inlet gas velocity. The NH 3 absorption rate will increase first and then tends to remain unchanged after reaching a certain degree with the increase in liquid injection flow rate and absorbent concentration. The NH 3 absorption rate will increase first and then decrease with the increase in the absorbent temperature. The maximum NH 3 removal efficiencies of water and H 3 PO 4 were 96% and 99%, respectively.
NASA Technical Reports Server (NTRS)
Cheng, S. W. S.
1982-01-01
The development of the Resonant Doppler Velocimeter (RDV) is discussed. It is a new nonintrusive laser technique for flow diagnosis. The RDV technique is applied to supersonic nitrogen flow with sodium atoms as tracer particles. The measurements are achieved by shining a tunable single frequency laser beam into the flow. The resonant absorption spectrum of the seeded species is determined by observing the fluorescence signal intensity as a function of excitation wavelength. By comparing the peak absorption wavelength with a reference frequency marker, the flow velocity along the excitation beam can be obtained through the Doppler shift relation. By fitting the spectrum with a theoretical line profile, the static temperature and pressure of the flow an be determined.
Absorption Filter Based Optical Diagnostics in High Speed Flows
NASA Technical Reports Server (NTRS)
Samimy, Mo; Elliott, Gregory; Arnette, Stephen
1996-01-01
Two major regimes where laser light scattered by molecules or particles in a flow contains significant information about the flow are Mie scattering and Rayleigh scattering. Mie scattering is used to obtain only velocity information, while Rayleigh scattering can be used to measure both the velocity and the thermodynamic properties of the flow. Now, recently introduced (1990, 1991) absorption filter based diagnostic techniques have started a new era in flow visualization, simultaneous velocity and thermodynamic measurements, and planar velocity measurements. Using a filtered planar velocimetry (FPV) technique, we have modified the optically thick iodine filter profile of Miles, et al., and used it in the pressure-broaden regime which accommodates measurements in a wide range of velocity applications. Measuring velocity and thermodynamic properties simultaneously, using absorption filtered based Rayleigh scattering, involves not only the measurement of the Doppler shift, but also the spectral profile of the Rayleigh scattering signal. Using multiple observation angles, simultaneous measurement of one component velocity and thermodynamic properties in a supersonic jet were measured. Presently, the technique is being extended for simultaneous measurements of all three components of velocity and thermodynamic properties.
Borycki, Dawid; Kholiqov, Oybek; Srinivasan, Vivek J
2017-02-01
Interferometric near-infrared spectroscopy (iNIRS) is a new technique that measures time-of-flight- (TOF-) resolved autocorrelations in turbid media, enabling simultaneous estimation of optical and dynamical properties. Here, we demonstrate reflectance-mode iNIRS for noninvasive monitoring of a mouse brain in vivo. A method for more precise quantification with less static interference from superficial layers, based on separating static and dynamic components of the optical field autocorrelation, is presented. Absolute values of absorption, reduced scattering, and blood flow index (BFI) are measured, and changes in BFI and absorption are monitored during a hypercapnic challenge. Absorption changes from TOF-resolved iNIRS agree with absorption changes from continuous wave NIRS analysis, based on TOF-integrated light intensity changes, an effective path length, and the modified Beer-Lambert Law. Thus, iNIRS is a promising approach for quantitative and noninvasive monitoring of perfusion and optical properties in vivo.
Don't Let a Good Scare Frighten You: Choosing and Using Quality Chillers to Promote Reading.
ERIC Educational Resources Information Center
Richards, Patricia O.; Thatcher, Debra H.; Shreeves, Michelle; Timmons, Peggy; Barker, Sallie
1999-01-01
Investigates why children are attracted to scary books, and what they find scary. Addresses children's fears through scary books and the instructional value of scary books. Discusses successful classroom experiences with scary books and notes selection considerations. Offers literature study ideas and a 100-item bibliography of scary books. (SR)
Packed fluidized bed blanket for fusion reactor
Chi, John W. H.
1984-01-01
A packed fluidized bed blanket for a fusion reactor providing for efficient radiation absorption for energy recovery, efficient neutron absorption for nuclear transformations, ease of blanket removal, processing and replacement, and on-line fueling/refueling. The blanket of the reactor contains a bed of stationary particles during reactor operation, cooled by a radial flow of coolant. During fueling/refueling, an axial flow is introduced into the bed in stages at various axial locations to fluidize the bed. When desired, the fluidization flow can be used to remove particles from the blanket.
Evaluation of the structures size in the liquid-gas flow by gamma-ray absorption
NASA Astrophysics Data System (ADS)
Zych, Marcin; Hanus, Robert; Jaszczur, Marek; Świsulski, Dariusz; Petryka, Leszek; Jodłowski, Paweł; Zych, Piotr
2018-06-01
The rapid development of tomography methods particularly electrical, X and gamma rays allows for a wide range of the information about flow structure. However, all of such methods are quite complicated. At the same time much simpler systems as the measuring system of gamma rays absorption, allows to obtain a all key flow information which describe the two-phase flow. In the article the results of analyzes of radiometric signal that not only allow to recognize the type of flow, but also the assessment of forming structures are presented. Calculation and interpretation of the data were based on the crosscorrelation and cross-spectral density function. In order to verify the calculations the photographic documentation made during the measurements was used.
IR multiphoton absorption of SF6 in flow with Ar at moderate energy fluences
NASA Astrophysics Data System (ADS)
Makarov, G. N.; Ronander, E.; van Heerden, S. P.; Gouws, M.; van der Merwe, K.
1997-10-01
IR multiple photon absorption (MPA) of SF6 in flow with Ar (SF6: Ar=1:100) in conditions of a large vibrational/rotational temperature difference (TV𪒮 K, TR䏐 K) was studied at moderate energy fluences from ۂ.1 to 𪐬 mJ/cm2, which are of interest for isotope selective two-step dissociation of molecules. A 50 cm Laval-type slit nozzle for the flow cooling, and a TEA CO2-laser for excitation of molecules were used in the experiments. The laser energy fluence dependences of the SF6 MPA were studied for several CO2-laser lines which are in a good resonance with the linear absorption spectrum of the Ƚ vibration of SF6 at low temperature. The effect of the laser pulse duration (intensity) on MPA of flow cooled SF6 with Ar was also studied. The results are compared with those obtained in earlier studies.
NASA Astrophysics Data System (ADS)
Kartohardjono, Sutrasno; Alexander, Kevin; Larasati, Annisa; Sihombing, Ivander Christian
2018-03-01
Carbon dioxide is pollutant in natural gas that could reduce the heating value of the natural gas and cause problem in transportation due to corrosive to the pipeline. This study aims to evaluate the effects of feed gas flow rate on CO2 absorption through super hydrophobic hollow fiber contactor. Polyethyleneglycol-300 (PEG-300) solution was used as absorbent in this study, whilst the feed gas used in the experiment was a mixture of 30% CO2 and 70% CH4. There are three super hydrophobic hollow fiber contactors sized 6 cm and 25 cm in diameter and length used in this study, which consists of 1000, 3000 and 5000 fibers, respectively. The super hydrophobic fiber membrane used is polypropylene-based with outer and inner diameter of about 525 and 235 μm, respectively. In the experiments, the feed gas was sent through the shell side of the membrane contactor, whilst the absorbent solution was pumped through the lumen fibers. The experimental results showed that the mass transfer coefficient, flux, absorption efficiency for CO2-N2 system and CO2 loading increased with the feed gas flow rate, but the absorption efficiency for CO2-N2 system decreased. The mass transfer coefficient and the flux, at the same feed gas flow rate, decreased with the number of fibers in the membrane contactor, but the CO2 absorption efficiency and the CO2 loading increased.
NASA Astrophysics Data System (ADS)
Immanuel, Y.; Pullepu, Bapuji; Sambath, P.
2018-04-01
A two dimensional mathematical model is formulated for the transitive laminar free convective, incompressible viscous fluid flow over vertical cone with variable surface heat flux combined with the effects of heat generation and absorption is considered . using a powerful computational method based on thermoelectric analogy called Network Simulation Method (NSM0, the solutions of governing nondimensionl coupled, unsteady and nonlinear partial differential conservation equations of the flow that are obtained. The numerical technique is always stable and convergent which establish high efficiency and accuracy by employing network simulator computer code Pspice. The effects of velocity and temperature profiles have been analyzed for various factors, namely Prandtl number Pr, heat flux power law exponent n and heat generation/absorption parameter Δ are analyzed graphically.
USDA-ARS?s Scientific Manuscript database
An experiment was conducted to determine if ergot alkaloids affect blood flow to the absorptive surface of the rumen. Steers (n = 8) were pair-fed alfalfa cubes and received ground endophyte-infected tall fescue seed (E+; 0.015 mg ergovaline•kg BW-1•d-1) or endophyte-free tall fescue seed (E-) via r...
NASA Astrophysics Data System (ADS)
Bravo, Teresa; Maury, Cédric
2018-03-01
This paper describes analytical and experimental studies carried out to examine the attenuation and absorption properties of rigidly-backed fibrous anisotropic materials in contact with a uniform mean flow. The aim is to provide insights for the development of non-locally reacting wall-treatments able to dissipate the noise induced by acoustic excitations over in-duct or external lining systems. A model of sound propagation in anisotropic bulk-reacting liners is presented that fully accounts for anisotropic losses due to heat conduction, viscous dissipation and diffusion processes along and across the material fibres as well as for the convective effect of an external flow. The propagation constant for the least attenuated mode of the coupled system is obtained using a simulated annealing search method. The predicted acoustical performance is validated in the no-flow case for a wide range of fibre diameters. They are assessed against impedance tube and free-field pressure-velocity measurements of the normal incidence absorption coefficient and surface impedance. Parametric studies are then conducted to determine the key constitutive parameters such as the fibres orientation or the amount of anisotropy that mostly influence the axial attenuation or the normal absorption. They are supported by a low-frequency approximation to the axial attenuation under a low-speed flow.
NASA Astrophysics Data System (ADS)
Wei, Chen-Wei; Xia, Jinjun; Pelivanov, Ivan; Hu, Xiaoge; Gao, Xiaohu; O'Donnell, Matthew
2012-10-01
Results on magnetically trapping and manipulating micro-scale beads circulating in a flow field mimicking metastatic cancer cells in human peripheral vessels are presented. Composite contrast agents combining magneto-sensitive nanospheres and highly optical absorptive gold nanorods were conjugated to micro-scale polystyrene beads. To efficiently trap the targeted objects in a fast stream, a dual magnet system consisting of two flat magnets to magnetize (polarize) the contrast agent and an array of cone magnets producing a sharp gradient field to trap the magnetized contrast agent was designed and constructed. A water-ink solution with an optical absorption coefficient of 10 cm-1 was used to mimic the optical absorption of blood. Magnetomotive photoacoustic imaging helped visualize bead trapping, dynamic manipulation of trapped beads in a flow field, and the subtraction of stationary background signals insensitive to the magnetic field. The results show that trafficking micro-scale objects can be effectively trapped in a stream with a flow rate up to 12 ml/min and the background can be significantly (greater than 15 dB) suppressed. It makes the proposed method very promising for sensitive detection of rare circulating tumor cells within high flow vessels with a highly absorptive optical background.
Radiation Pressure-Driven Magnetic Disk Winds in Broad Absorption Line Quasi-Stellar Objects
NASA Technical Reports Server (NTRS)
DeKool, Martin; Begelman, Mitchell C.
1995-01-01
We explore a model in which QSO broad absorption lines (BALS) are formed in a radiation pressure-driven wind emerging from a magnetized accretion disk. The magnetic field threading the disk material is dragged by the flow and is compressed by the radiation pressure until it is dynamically important and strong enough to contribute to the confinement of the BAL clouds. We construct a simple self-similar model for such radiatively driven magnetized disk winds, in order to explore their properties. It is found that solutions exist for which the entire magnetized flow is confined to a thin wedge over the surface of the disk. For reasonable values of the mass-loss rate, a typical magnetic field strength such that the magnetic pressure is comparable to the inferred gas pressure in BAL clouds, and a moderate amount of internal soft X-ray absorption, we find that the opening angle of the flow is approximately 0.1 rad, in good agreement with the observed covering factor of the broad absorption line region.
Thriller-Dillers & Chillers. Wisconsin Summer Library Program Manual, 1985. Bulletin No. 5212.
ERIC Educational Resources Information Center
Johnson, Debra Wilcox, Ed.
The Wisconsin Summer Library Program was developed to promote use of the library by children during the summer, to familiarize them with the resources of the public library, and to help them retain their reading skills over the summer. Different ways of interpreting the theme of the summer program for 1985 were suggested by librarians throughout…
Development of an automated energy audit protocol for office buildings
NASA Astrophysics Data System (ADS)
Deb, Chirag
This study aims to enhance the building energy audit process, and bring about reduction in time and cost requirements in the conduction of a full physical audit. For this, a total of 5 Energy Service Companies in Singapore have collaborated and provided energy audit reports for 62 office buildings. Several statistical techniques are adopted to analyse these reports. These techniques comprise cluster analysis and development of prediction models to predict energy savings for buildings. The cluster analysis shows that there are 3 clusters of buildings experiencing different levels of energy savings. To understand the effect of building variables on the change in EUI, a robust iterative process for selecting the appropriate variables is developed. The results show that the 4 variables of GFA, non-air-conditioning energy consumption, average chiller plant efficiency and installed capacity of chillers should be taken for clustering. This analysis is extended to the development of prediction models using linear regression and artificial neural networks (ANN). An exhaustive variable selection algorithm is developed to select the input variables for the two energy saving prediction models. The results show that the ANN prediction model can predict the energy saving potential of a given building with an accuracy of +/-14.8%.
Evaluation of Water consumption and savings achieved in Datacenters through Air side Economization
NASA Astrophysics Data System (ADS)
Mishra, Ravi
Recent researches and a few facility owners have focused on eliminating the chiller plant altogether by implementing 'Evaporative Cooling', as an alternative or augmentation to compressor-based air conditioning since the energy consumption is dominated by the compressor work (around 41%) in the chiller plant. Because evaporative cooling systems consume water, when evaluating the energy savings potential of these systems, it is imperative to consider not just their impacts on electricity use, but also their impacts on water consumption as well since Joe Kava, Google's head of data center operations, was quoted as saying that water is the "big elephant in the room" for data center companies. The objective of this study was to calculate the savings achieved in water consumption when these evaporative cooling systems were completely or partially marginalized when the facility is strictly working in the Economizer mode also known as 'free cooling' considering other modes of cooling required only for a part of the time when outside temperature, humidity and pollutant level were unfavorable causing improper functioning and reliability issues. The analysis was done on ASHRAE climatic zones with the help of TMY-3 weather data.
Uma, Kasimayan; Pan, Guan-Ting; Yang, Thomas C.-K.
2017-01-01
Metal organic framework (MOF) of MIL-101(Cr)-Silica (SiO2) composites with highly mesoporous and uniform dispersions were synthesized by a microwave-assisted hydrothermal method followed by the sol-gel technique. Water vapor adsorption experiments were conducted on the MIL-101(Cr)-SiO2 composites for industrial adsorption chiller applications. The effects of MIL-101(Cr)-SiO2 mixing ratios (ranging from 0% to 52%), the surface area and amount of Lewis and Brønsted sites were comprehensively determined through water vapor adsorption experiments and the adsorption mechanism is also explained. The BET and Langmuir results indicate that the adsorption isotherms associated with the various MIL-101(Cr)-SiO2 ratios demonstrated Type I and IV adsorption behavior, due to the mesoporous structure of the MIL-101(Cr)-SiO2. It was observed that the increase in the amount of Lewis and Brønsted sites on the MIL-101(Cr)-SiO2 composites significantly improves the water vapor adsorption efficiency, for greater stability during the water vapor adsorption experiments. PMID:28772969
Vallon, Raphäel; Soutadé, Jacques; Vérant, Jean-Luc; Meyers, Jason; Paris, Sébastien; Mohamed, Ajmal
2010-01-01
Since the beginning of the Mars planet exploration, the characterization of carbon dioxide hypersonic flows to simulate a spaceship's Mars atmosphere entry conditions has been an important issue. We have developed a Tunable Diode Laser Absorption Spectrometer with a new room-temperature operating antimony-based distributed feedback laser (DFB) diode laser to characterize the velocity, the temperature and the density of such flows. This instrument has been tested during two measurement campaigns in a free piston tunnel cold hypersonic facility and in a high enthalpy arc jet wind tunnel. These tests also demonstrate the feasibility of mid-infrared fiber optics coupling of the spectrometer to a wind tunnel for integrated or local flow characterization with an optical probe placed in the flow.
Hart, Roger C; Herring, G C; Balla, R Jeffrey
2007-06-15
Nonintrusive, off-body flow barometry in Mach 2 airflow has been demonstrated in a large-scale supersonic wind tunnel using seedless laser-induced thermal acoustics (LITA). The static pressure of the gas flow is determined with a novel differential absorption measurement of the ultrasonic sound produced by the LITA pump process. Simultaneously, the streamwise velocity and static gas temperature of the same spatially resolved sample volume were measured with this nonresonant time-averaged LITA technique. Mach number, temperature, and pressure have 0.2%, 0.4%, and 4% rms agreement, respectively, in comparison with known free-stream conditions.
NASA Technical Reports Server (NTRS)
Hart, Roger C.; Herring, Gregory C.; Balla, Robert J.
2007-01-01
Nonintrusive, off-body flow barometry in Mach-2 airflow has been demonstrated in a large-scale supersonic wind tunnel using seedless laser-induced thermal acoustics (LITA). The static pressure of the gas flow is determined with a novel differential absorption measurement of the ultrasonic sound produced by the LITA pump process. Simultaneously, stream-wise velocity and static gas temperature of the same spatially-resolved sample volume were measured with this nonresonant time-averaged LITA technique. Mach number, temperature and pressure have 0.2%, 0.4%, and 4% rms agreement, respectively, in comparison with known free-stream conditions.
Smolentsev, Grigory; Guda, Alexander; Zhang, Xiaoyi; Haldrup, Kristoffer; Andreiadis, Eugen; Chavarot-Kerlidou, Murielle; Canton, Sophie E; Nachtegaal, Maarten; Artero, Vincent; Sundstrom, Villy
2013-08-29
A new setup for pump-flow-probe X-ray absorption spectroscopy has been implemented at the SuperXAS beamline of the Swiss Light Source. It allows recording X-ray absorption spectra with a time resolution of tens of microseconds and high detection efficiency for samples with sub-mM concentrations. A continuous wave laser is used for the photoexcitation, with the distance between laser and X-ray beams and velocity of liquid flow determining the time delay, while the focusing of both beams and the flow speed define the time resolution. This method is compared with the alternative measurement technique that utilizes a 1 kHz repetition rate laser and multiple X-ray probe pulses. Such an experiment was performed at beamline 11ID-D of the Advanced Photon Source. Advantages, limitations and potential for improvement of the pump-flow-probe setup are discussed by analyzing the photon statistics. Both methods, with Co K-edge probing were applied to the investigation of a cobaloxime-based photo-catalytic reaction. The interplay between optimizing for efficient photoexcitation and time resolution as well as the effect of sample degradation for these two setups are discussed.
Smolentsev, Grigory; Guda, Alexander; Zhang, XIaoyi; Haldrup, Kristoffer; Andreiadis, Eugen; Chavarot-Kerlidou, Murielle; Canton, Sophie E.; Nachtegaal, Maarten; Artero, Vincent; Sundstrom, Villy
2014-01-01
A new setup for pump-flow-probe X-ray absorption spectroscopy has been implemented at the SuperXAS beamline of the Swiss Light Source. It allows recording X-ray absorption spectra with a time resolution of tens of microseconds and high detection efficiency for samples with sub-mM concentrations. A continuous wave laser is used for the photoexcitation, with the distance between laser and X-ray beams and velocity of liquid flow determining the time delay, while the focusing of both beams and the flow speed define the time resolution. This method is compared with the alternative measurement technique that utilizes a 1 kHz repetition rate laser and multiple X-ray probe pulses. Such an experiment was performed at beamline 11ID-D of the Advanced Photon Source. Advantages, limitations and potential for improvement of the pump-flow-probe setup are discussed by analyzing the photon statistics. Both methods, with Co K-edge probing were applied to the investigation of a cobaloxime-based photo-catalytic reaction. The interplay between optimizing for efficient photoexcitation and time resolution as well as the effect of sample degradation for these two setups are discussed. PMID:24443663
NASA Astrophysics Data System (ADS)
Hayat, Tasawar; Qayyum, Sajid; Shehzad, Sabir Ali; Alsaedi, Ahmed
2018-03-01
The present research article focuses on three-dimensional flow of viscoelastic(second grade) nanofluid in the presence of Cattaneo-Christov double-diffusion theory. Flow caused is due to stretching sheet. Characteristics of heat transfer are interpreted by considering the heat generation/absorption. Nanofluid theory comprises of Brownian motion and thermophoresis. Cattaneo-Christov double-diffusion theory is introduced in the energy and concentration expressions. Such diffusions are developed as a part of formulating the thermal and solutal relaxation times framework. Suitable variables are implemented for the conversion of partial differential systems into a sets of ordinary differential equations. The transformed expressions have been explored through homotopic algorithm. Behavior of sundry variables on the velocities, temperature and concentration are scrutinized graphically. Numerical values of skin friction coefficients are also calculated and examined. Here thermal field enhances for heat generation parameter while reverse situation is noticed for heat absorption parameter.
Laser Velocimeter for Studies of Microgravity Combustion Flowfields
NASA Technical Reports Server (NTRS)
Varghese, P. L.; Jagodzinski, J.
2001-01-01
We are currently developing a velocimeter based on modulated filtered Rayleigh scattering (MFRS), utilizing diode lasers to make measurements in an unseeded gas or flame. MFRS is a novel variation of filtered Rayleigh scattering, utilizing modulation absorption spectroscopy to detect a strong absorption of a weak Rayleigh scattered signal. A rubidium (Rb) vapor filter is used to provide the relatively strong absorption and semiconductor diode lasers generate the relatively weak Rayleigh scattered signal. Alkali metal vapors have a high optical depth at modest vapor pressures, and their narrow linewidth is ideally suited for high-resolution velocimetry; the compact, rugged construction of diode lasers makes them ideally suited for microgravity experimentation. Molecular Rayleigh scattering of laser light simplifies flow measurements as it obviates the complications of flow-seeding. The MFRS velocimeter should offer an attractive alternative to comparable systems, providing a relatively inexpensive means of measuring velocity in unseeded flows and flames.
Laser absorption phenomena in flowing gas devices
NASA Technical Reports Server (NTRS)
Chapman, P. K.; Otis, J. H.
1976-01-01
A theoretical and experimental investigation is presented of inverse Bremsstrahlung absorption of CW CO2 laser radiation in flowing gases seeded with alkali metals. In order to motivate this development, some simple models are described of several space missions which could use laser powered rocket vehicles. Design considerations are given for a test call to be used with a welding laser, using a diamond window for admission of laser radiation at power levels in excess of 10 kW. A detailed analysis of absorption conditions in the test cell is included. The experimental apparatus and test setup are described and the results of experiments presented. Injection of alkali seedant and steady state absorption of the laser radiation were successfully demonstrated, but problems with the durability of the diamond windows at higher powers prevented operation of the test cell as an effective laser powered thruster.
NASA Astrophysics Data System (ADS)
Bravo, Teresa; Maury, Cédric
2018-07-01
Enhancing the attenuation or the absorption of low-frequency noise using lightweight bulk-reacting liners is still a demanding task in surface and air transport systems. The aim of this study is to understand the physical mechanisms involved in the attenuation and absorption properties of partitions made up of a thin micro-perforated panel (MPP) rigidly backed by a cavity filled with anisotropic fibrous material. Such a layout is denoted as a MPPF partition. Analytical models are formulated in the flow and no-flow cases to predict the axial damping of the least attenuated wave in a MPPF partition as well as the plane wave absorption coefficient. They account for a rigid or an elastic MPP facing a bulk-reacting fully-anisotropic material. A cost-efficient solution of the propagation constant for the least attenuated mode is obtained using a simulated annealing search method as well as a low-frequency approximation to the axial attenuation. The normal incidence absorption model is assessed in the no-flow case against pressure-velocity measurements of the surface impedance over a MPPF partition filled with fibreglass material. A parametric study is conducted to evaluate the MPP and the cavity constitutive parameters that mostly enhance the axial attenuation and sound absorption properties, with special interest on the MPP airframe relative velocity. This sensitivity study provides guidelines that could be used to further reduce the search space in parametric or impedance optimization studies.
Borycki, Dawid; Kholiqov, Oybek; Srinivasan, Vivek J.
2017-01-01
Interferometric near-infrared spectroscopy (iNIRS) is a new technique that measures time-of-flight- (TOF-) resolved autocorrelations in turbid media, enabling simultaneous estimation of optical and dynamical properties. Here, we demonstrate reflectance-mode iNIRS for noninvasive monitoring of a mouse brain in vivo. A method for more precise quantification with less static interference from superficial layers, based on separating static and dynamic components of the optical field autocorrelation, is presented. Absolute values of absorption, reduced scattering, and blood flow index (BFI) are measured, and changes in BFI and absorption are monitored during a hypercapnic challenge. Absorption changes from TOF-resolved iNIRS agree with absorption changes from continuous wave NIRS analysis, based on TOF-integrated light intensity changes, an effective path length, and the modified Beer–Lambert Law. Thus, iNIRS is a promising approach for quantitative and non-invasive monitoring of perfusion and optical properties in vivo. PMID:28146535
Diode laser absorption sensors for gas-dynamic and combustion flows
NASA Technical Reports Server (NTRS)
Allen, M. G.
1998-01-01
Recent advances in room-temperature, near-IR and visible diode laser sources for tele-communication, high-speed computer networks, and optical data storage applications are enabling a new generation of gas-dynamic and combustion-flow sensors based on laser absorption spectroscopy. In addition to conventional species concentration and density measurements, spectroscopic techniques for temperature, velocity, pressure and mass flux have been demonstrated in laboratory, industrial and technical flows. Combined with fibreoptic distribution networks and ultrasensitive detection strategies, compact and portable sensors are now appearing for a variety of applications. In many cases, the superior spectroscopic quality of the new laser sources compared with earlier cryogenic, mid-IR devices is allowing increased sensitivity of trace species measurements, high-precision spectroscopy of major gas constituents, and stable, autonomous measurement systems. The purpose of this article is to review recent progress in this field and suggest likely directions for future research and development. The various laser-source technologies are briefly reviewed as they relate to sensor applications. Basic theory for laser absorption measurements of gas-dynamic properties is reviewed and special detection strategies for the weak near-IR and visible absorption spectra are described. Typical sensor configurations are described and compared for various application scenarios, ranging from laboratory research to automated field and airborne packages. Recent applications of gas-dynamic sensors for air flows and fluxes of trace atmospheric species are presented. Applications of gas-dynamic and combustion sensors to research and development of high-speed flows aeropropulsion engines, and combustion emissions monitoring are presented in detail, along with emerging flow control systems based on these new sensors. Finally, technology in nonlinear frequency conversion, UV laser materials, room-temperature mid-IR materials and broadly tunable multisection devices is reviewed to suggest new sensor possibilities.
Naftalin, Richard J.
2016-01-01
A computer model designed to simulate integrated glucose-dependent changes in splanchnic blood flow with small intestinal glucose absorption, hormonal and incretin circulation and hepatic and systemic metabolism in health and metabolic diseases e.g. non-alcoholic fatty liver disease, (NAFLD), non-alcoholic steatohepatitis, (NASH) and type 2 diabetes mellitus, (T2DM) demonstrates how when glucagon-like peptide-1, (GLP-1) is synchronously released into the splanchnic blood during intestinal glucose absorption, it stimulates superior mesenteric arterial (SMA) blood flow and by increasing passive intestinal glucose absorption, harmonizes absorption with its distribution and metabolism. GLP-1 also synergises insulin-dependent net hepatic glucose uptake (NHGU). When GLP-1 secretion is deficient post-prandial SMA blood flow is not increased and as NHGU is also reduced, hyperglycaemia follows. Portal venous glucose concentration is also raised, thereby retarding the passive component of intestinal glucose absorption. Increased pre-hepatic sinusoidal resistance combined with portal hypertension leading to opening of intrahepatic portosystemic collateral vessels are NASH-related mechanical defects that alter the balance between splanchnic and systemic distributions of glucose, hormones and incretins.The model reveals the latent contribution of portosystemic shunting in development of metabolic disease. This diverts splanchnic blood content away from the hepatic sinuses to the systemic circulation, particularly during the glucose absorptive phase of digestion, resulting in inappropriate increases in insulin-dependent systemic glucose metabolism. This hastens onset of hypoglycaemia and thence hyperglucagonaemia. The model reveals that low rates of GLP-1 secretion, frequently associated with T2DM and NASH, may be also be caused by splanchnic hypoglycaemia, rather than to intrinsic loss of incretin secretory capacity. These findings may have therapeutic implications on GLP-1 agonist or glucagon antagonist usage. PMID:27347379
Vallon, Raphäel; Soutadé, Jacques; Vérant, Jean-Luc; Meyers, Jason; Paris, Sébastien; Mohamed, Ajmal
2010-01-01
Since the beginning of the Mars planet exploration, the characterization of carbon dioxide hypersonic flows to simulate a spaceship’s Mars atmosphere entry conditions has been an important issue. We have developed a Tunable Diode Laser Absorption Spectrometer with a new room-temperature operating antimony-based distributed feedback laser (DFB) diode laser to characterize the velocity, the temperature and the density of such flows. This instrument has been tested during two measurement campaigns in a free piston tunnel cold hypersonic facility and in a high enthalpy arc jet wind tunnel. These tests also demonstrate the feasibility of mid-infrared fiber optics coupling of the spectrometer to a wind tunnel for integrated or local flow characterization with an optical probe placed in the flow. PMID:22219703
The absorption of sound by perforated linings
NASA Astrophysics Data System (ADS)
Hughes, I. J.; Dowling, A. P.
1990-09-01
This paper describes a practical application for sound-absorbent perforated screen with a bias flow through the screen. It is postulated that, if a perforated liner with a bias flow of cooling air through the liner is inserted in the afterburner section of a jet engine, all the incident sound may be absorbed at a particular frequency. Experimental results are presented on the absorptive properties of plane liners with circular apertures, showing an agreement with the theoretical model.
An Analysis of Electrical Consumption at Representative Army Installations.
1980-05-01
can be done by analyzing and optimizing HVAC system and building operation. For example, if the minimum hourly usage (demand) of a typical bachelor...equipment. (Major candidates for scheduling are air-handler motors, chillers , air compressors, exhaust fans, exterior lights, hot water heaters, and hot...location: Thermostats Setpoint Measured Limiters Setback Area Temperature Temperature Yes No Yes No Are night setback thermostats recommended? Yes _ No
In-situ Charge Determination for Vapor Cycle Systems in Aircraft (Postprint)
2012-10-22
control and operation in support of the Energy Optimized Aircraft (EOA) initiative and the Integrated Vehicle ENergy Technology (INVENT) program...the Energy Optimized Aircraft (EOA) initiative and the Integrated Vehicle ENergy Technology (INVENT) program. Previous papers on ToTEMS have discussed...stationary chillers include a reduction in cooling capacity due to reduced availability of liquid for evaporation. In addition, the coefficient of
Code of Federal Regulations, 2010 CFR
2010-07-01
... line between the system liquid port and the receiving vessel. 3.7Recycle Rate. The amount of... 80 80 80 80 80 80 80 80 Acid content: PPM by weight of pure refrigerant—(mg KOH per kg refrig... chillers shall be 1.5 in. [38 mm.]. The mixing chamber shall contain various ports for receiving liquid...
Code of Federal Regulations, 2011 CFR
2011-07-01
... line between the system liquid port and the receiving vessel. 3.7Recycle Rate. The amount of... 80 80 80 80 80 80 80 80 Acid content: PPM by weight of pure refrigerant—(mg KOH per kg refrig... chillers shall be 1.5 in. [38 mm.]. The mixing chamber shall contain various ports for receiving liquid...
Treatment with a low pH processing aid to reduce campylobacter counts on broiler parts
USDA-ARS?s Scientific Manuscript database
This study evaluated the low pH processing aid – CMS PoultrypHresh™ (LPPA) to reduce Campylobacter on carcasses (3 groups of 6) collected prior to the chiller that were individually placed into a 38 L container with either 20 L tap water (pH = 7.3) or 20 L of LPPA solution (pH = 1.4) with air agita...
Jones, T H; Johns, M W; Gill, C O
2008-06-10
For better understanding of the complex behaviour of Escherichia coli at chiller temperatures, log phase E. coli grown at 15 degrees C were incubated at 8, 6, or 2 degrees C for 4 days, and were then incubated at 15 degrees C for 12 h. Cultures were sampled after incubation at the lower temperatures, and during subsequent incubation at 15 degrees C. Proteins extracted from the samples were separated by two-dimensional polyacrylamide gel electrophoresis (2D-PAGE). Spots of 45 previously identified proteins that were differentially expressed at 15 or < or =8 degrees C were quantified by image analysis. After incubation at 8 or 6 degrees C for 4 days cells were growing with or without formation of elongated cells (filaments), respectively, but growth did not occur at 2 degrees C. In cells incubated at 8 or 6 degrees C proteins associated with the stress response and energy generation were upregulated and proteins associated with protein synthesis were downregulated, while protein levels in cells incubated at 2 degrees C were little changed. When cells were then incubated at 15 degrees C, the levels of differentially expressed proteins in cells that had been incubated at 8 or 6 degrees C decreased or increased towards the levels found in cells growing at 15 degrees C, but some proteins were still under or over expressed after 12 h. In cells incubated at 15 degrees C after incubation at 2 degrees C, the levels of many of the proteins declined but the levels of proteins associated with protein synthesis increased. The findings indicate that the physiological states of log phase E. coli incubated at < or =2 degrees C or at higher chiller temperature are different, but that for both states incubation at an above chiller temperature for >3 generations is required before protein levels adjusted to those usual for the higher temperature. Cells in these different physiological states may respond differently to other stresses encountered during warming of chilled foods.
The Multistage Compressor Facility
NASA Technical Reports Server (NTRS)
Flegel, Ashlie
2004-01-01
Research and developments of new aerospace technologies is one of Glenn Research Center's specialties. One facility that deals with the research of aerospace technologies is the High-speed Multistage Compressor Facility. This facility will be testing the performance and efficiency of an Ultra Efficient Engine Technology (UEET) two-stage compressor. There is a lot of preparation involved with testing something of this caliber. Before the test article can be installed into the test rig, the facility must be fully operational and ready to run. Meaning all the necessary instrumentation must be calibrated and installed in the facility. The test rig should also be in safe operating condition, and the proper safety permits obtained. In preparation for the test, the Multistage Compressor Facility went through a few changes. For instance the facility will now be utilizing slip rings, the gearbox went through some maintenance, new lubrications systems replaced the old ones, and special instrumentation needs to be fine tuned to achieve the maximum amount of accurate data. Slips rings help gather information off of a rotating device - in this case from a shaft - onto stationary contacts. The contacts (or brushes) need to be cooled to reduce the amount of frictional heat produced between the slip ring and brushes. The coolant being run through the slip ring is AK-225, a material hazardous to the ozone. To abide by the safety regulations the coolant must be run through a closed chiller system. A new chiller system was purchased but the reservoir that holds the coolant was ventilated which doesn t make the system truly closed and sealed. My task was to design and have a new reservoir built for the chiller system that complies with the safety guidelines. The gearbox had some safety issues also. Located in the back of the gearbox an inching drive was set up. When the inching drive is in use the gears and chain are bare and someone can easily get caught up in it. So to prevent anyone from getting hurt in the gears I designed a chain guard. Additional information is included in the original extended abstract.
Axial and radial water flow in the trunks of oak trees: a quantitative and qualitative analysis.
Granier, A; Anfodillo, T; Sabatti, M; Cochard, H; Dreyer, E; Tomasi, M; Valentini, R; Bréda, N
1994-12-01
Axial water flow in the trunks of mature oak trees (Quercus petraea (Matt.) Liebl. and Q. robur L.) was studied by four independent techniques: water absorption from a cut trunk, sap flowmeters, heat pulse velocity (HPV) and thermoimaging. Estimation of the total water flow with sap flowmeters, HPV and water absorption yielded comparable results. We concluded from dye colorations, thermograms and axial profiles of sap flow and heat pulse velocity that, in intact trunks, most of the flow occurred in the current-year ring, where early-wood vessels in the outermost ring were still functional. Nevertheless, there was significant flow in the older rings of the xylem. Total water flow through the trunk was only slightly reduced when air embolisms were artificially induced in early-wood vessels, probably because there was little change in hydraulic conductance in the root-leaf sap pathway. Embolization of the current-year vessels reactivated transport in the older rings.
Singh, Shatrughan; D'Sa, Eurico; Swenson, Erick
2010-01-01
Absorption and fluorescence properties of chromophoric dissolved organic matter (CDOM) along a 124 km transect in the Barataria Basin, a large estuary located in Louisiana, USA, were investigated during high and low flow periods of the Mississippi River in the spring and winter of 2008-2009. Mean CDOM absorption at 355 nm from the marine to the freshwater end member stations ranged from (3.25 +/- 0.56) to (20.76 +/- 2.43) m(-1) for the three month high flow period whereas it varied from (1.48 +/- 1.08) to (25.45 +/- 7.03) m(-1) for the same stations during low flow period. Corresponding salinity values at these stations indicated the influence of river and shelf exchanges in the lower basin and precipitation and runoff in the upper basin. An inverse relationship of CDOM absorbance and fluorescence with salinity observed in the basin could be a useful indicator of salinity. CDOM fluorescence also varied over a large range showing an approximately 8 to 12-fold increase between the marine and freshwater end members for the two flow seasons. Excitation-emission matrix spectral plots indicated the presence of various fluorescence components with highest being the A-peak, lowest the T-peak, and the C and M-peaks showing similar trends along the transect. During low flow season the A/C ratio were well correlated with station locations indicating increased terrestrial influence towards the upper basin. CDOM absorption and fluorescence at 355 nm were highly correlated and independent of CDOM sources suggesting that fluorescence could be used to characterize CDOM in the basin.
NASA Technical Reports Server (NTRS)
Poe, C. H.; Owocki, S. P.; Castor, J. I.
1990-01-01
The steady state solution topology for absorption line-driven flows is investigated for the condition that the Sobolev approximation is not used to compute the line force. The solution topology near the sonic point is of the nodal type with two positive slope solutions. The shallower of these slopes applies to reasonable lower boundary conditions and realistic ion thermal speed v(th) and to the Sobolev limit of zero of the usual Castor, Abbott, and Klein model. At finite v(th), this solution consists of a family of very similar solutions converging on the sonic point. It is concluded that a non-Sobolev, absorption line-driven flow with a realistic values of v(th) has no uniquely defined steady state. To the extent that a pure absorption model of the outflow of stellar winds is applicable, radiatively driven winds should be intrinsically variable.
Wan, Jiangbo; Zhang, Guoan; Qiu, Yuxuan; Wen, Chunquan; Fu, Tairan
2016-05-01
This study aimed to further explore heat dissipation by blood circulation and airway tissue heat absorption in an inhalational thermal injury model. Twelve adult male Beagle dogs were divided into four groups to inhale heated air for 10min: the control group, group I (100.5°C), group II (161.5°C), and group III (218°C). The relative humidity and temperature of the inhaled heated air were measured in the heating tube and trachea, as were blood temperatures and flow velocities in both common jugular veins. Formulas were used to calculate the total heat quantity reduction of the heated air, heat dissipation by the blood, and airway tissue heat absorption. The blood temperatures of both the common jugular veins increased by 0.29°C±0.07°C to 2.96°C±0.24°C and the mean blood flow volume after injury induction was about 1.30-1.74 times greater than before injury induction. The proportions of heat dissipated by the blood and airway tissue heat absorption were 68.92%±14.88% and 31.13%±14.87%, respectively. The heat dissipating ability of the blood circulation was demonstrated and improved upon along with tissue heat absorption owing to increased regional blood flow. Copyright © 2015 Elsevier Ltd and ISBI. All rights reserved.
Zare-Dorabei, Rouholah; Boroun, Shokoufeh; Noroozifar, Meissam
2018-02-01
A new and simple flow injection method followed by atomic absorption spectrometry was developed for indirect determination of sulfite. The proposed method is based on the oxidation of sulfite to sulphate ion using solid-phase manganese dioxide (30% W/W suspended on silica gel beads) reactor. MnO 2 will be reduced to Mn(II) by sample injection in to the column under acidic carrier stream of HNO 3 (pH 2) with flow rate of 3.5mLmin -1 at room temperature. Absorption measurement of Mn(II) which is proportional to the concentration of sulfite in the sample was carried out by atomic absorption spectrometry. The calibration curve was linear up to 25mgL -1 with a detection limit (DL) of 0.08mgL -1 for 400µL injection sample volume. The presented method is efficient toward sulfite determination in sugar and water samples with a relative standard deviation (RSD) less than 1.2% and a sampling rate of about 60h -1 . Copyright © 2017 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bigham, S; Yu, DZ; Chugh, D
2014-02-01
The slow diffusion of an absorbate molecule into an absorbent often makes the absorption process a rate-limiting step in many applications. In cases involving an absorbate with a high heat of phase change, such as water absorption into a LiBr (lithium bromide) solution, the absorption rate is further slowed due to significant heating of the absorbent. Recently, it has been demonstrated that constraining a LiBr solution film by a hydrophobic porous structure enables manipulation of the solution flow thermohydraulic characteristics. Here, it is shown that mass transport mode in a constrained laminar solution flow can be changed from diffusive tomore » advective. This change in mode is accomplished through stretching and folding the laminar streamlines within the solution film via the implementation of micro-scale features on the flow channel surface. The process induces vortices within the solution film, which continuously bring concentrated solution from the bottom and middle of the solution channel to its interface with the vapor phase, thus leading to a significant enhancement in the absorption rate. The detailed physics of the involved transport processes is elucidated using the LBM (Lattice Boltzmann Method). Published by Elsevier Ltd.« less
Simulation model of a single-stage lithium bromide-water absorption cooling unit
NASA Technical Reports Server (NTRS)
Miao, D.
1978-01-01
A computer model of a LiBr-H2O single-stage absorption machine was developed. The model, utilizing a given set of design data such as water-flow rates and inlet or outlet temperatures of these flow rates but without knowing the interior characteristics of the machine (heat transfer rates and surface areas), can be used to predict or simulate off-design performance. Results from 130 off-design cases for a given commercial machine agree with the published data within 2 percent.
[Determination of mercury in Boletus impolitus by flow injection-atomic absorption spectrometry].
Li, Tao; Wang, Yuan-Zhong
2008-04-01
Various test conditions and effect factors for the determination of mercury by flow injection-atomic absorption spectrometry were discussed, and a method for the determination of mercury in Boletus impolitus has been developed. The linear range for mercury is 0-60 microg x L(-1). The relative standard deviation is less than 3.0%, and the recovery is 96%-107%. This method is simple, rapid and has been applied to the determination of mercury in Boletus impolitus samples with satisfactory results.
Wijmans, Johannes G.; Baker, Richard W.; Merkel, Timothy C.
2012-08-21
A gas separation process for treating flue gases from combustion processes, and combustion processes including such gas separation. The invention involves routing a first portion of the flue gas stream to be treated to an absorption-based carbon dioxide capture step, while simultaneously flowing a second portion of the flue gas across the feed side of a membrane, flowing a sweep gas stream, usually air, across the permeate side, then passing the permeate/sweep gas to the combustor.
Experimental Study of Aligned and Staggered Wind Farms in a Convective Boundary Layer
NASA Astrophysics Data System (ADS)
Markfort, Corey; Zhang, Wei; Porte-Agel, Fernando
2011-11-01
Wind farm-atmosphere interaction is complicated by turbine configuration and thermal effects on momentum and kinetic energy fluxes. Wind farms of finite length have been modeled as increased surface roughness or as a sparse canopy; however it is not clear which approach is more appropriate. Experiments were conducted in a thermally controlled boundary layer wind tunnel, using a custom x-wire/cold wire and surface heat flux sensors, to understand the effect of aligned versus staggered turbine configurations on momentum absorption and flow adjustment in a convective boundary layer (CBL). Results for experiments of a large farm show the span-wise averaged flow statistics exhibit similar turbulent transport properties to that of canopy flows. The wake adjusts within and grows over the farm more quickly for a staggered compared to an aligned farm. Using canopy flow scaling, we show that the flow equilibrates faster and the overall momentum absorption is higher in a staggered compared to an aligned farm. Wake recovery behind a single turbine is facilitated by buoyancy in a CBL (Zhang et al. under review). We find a similar effect in wind farms resulting in reduced effective roughness and momentum absorption. We also find a reduction of surface heat flux for both wind farms, but greater for the staggered farm.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bobarykina, T A; Malov, A N; Orishich, A M
We report a study of the wave structure formed by an optical discharge plasma upon the absorption of repetitively pulsed CO{sub 2} laser radiation in a supersonic (M = 1.36) air flow. Experimental data are presented on the configuration of the head shock wave and the geometry and characteristic dimensions of breakdown regions behind a laser plasma pulsating in the flow at a frequency of up to 150 kHz. The data are compared to calculation in a point explosion model with allowance for counterpressure, which makes it possible to identify the relationship between laser radiation and supersonic flow parameters thatmore » ensures quasisteady- state energy delivery and is necessary for extending the possibilities of controlling the structure of supersonic flows. (interaction of laser radiation with matter)« less
Schmidely, P; Glasser, F; Doreau, M; Sauvant, D
2008-05-01
A database built from 95 experiments with 303 treatments was used to quantify the ruminal biohydrogenation (BH) of fatty acids (FA), efficiency of microbial protein synthesis (EMPS), duodenal flow and intestinal absorption of total FA and of FA with 12 to 18 C units, in response to variations in dietary FA content, source or technological treatment of fat supplement. Flows of FA were expressed relative to dry matter intake (DMI) to compile data from bovine and ovine species. BH tended to increase curvilinearly with FA intake, whereas dietary FA did not affect EMPS. A linear relationship between FA intake and duodenal flow of total FA was obtained, with a coefficient of 0.75 ± 0.06 g duodenal FA/kg DMI for each g FA intake/kg DMI. Between experiments, positive balances of total FA (intake - duodenum) were related to low EMPS. Relationships between duodenal flows of FA with 12 to 18 C units and their respective intakes were linear, with a coefficient that increased with the number of C units. Duodenal flow of bacterial FA was linearly related to FA intake (coefficient 0.33 ± 0.13), whereas contribution of bacterial lipid to duodenal flow decreased as FA intake increased. For each FA with 12 to 16 C units, prediction of FA absorption from its respective duodenal flow was linear. For total FA and FA with 18 C units, apparent absorption levelled off at high duodenal flows. All these relationships were discussed according to current knowledge on microbial metabolism in the rumen and on the intestinal digestibility of FA in the intestine.
Hiraguchi, Ryuji; Hazama, Hisanao; Senoo, Kenichirou; Yahata, Yukinori; Masuda, Katsuyoshi; Awazu, Kunio
2014-01-01
A continuous flow atmospheric pressure laser desorption/ionization technique using a porous stainless steel probe and a 6–7-µm-band mid-infrared tunable laser was developed. This ion source is capable of direct ionization from a continuous flow with a high temporal stability. The 6–7-µm wavelength region corresponds to the characteristic absorption bands of various molecular vibration modes, including O–H, C=O, CH3 and C–N bonds. Consequently, many organic compounds and solvents, including water, have characteristic absorption peaks in this region. This ion source requires no additional matrix, and utilizes water or acetonitrile as the solvent matrix at several absorption peak wavelengths (6.05 and 7.27 µm, respectively). The distribution of multiply-charged peptide ions is extremely sensitive to the temperature of the heated capillary, which is the inlet of the mass spectrometer. This ionization technique has potential for the interface of liquid chromatography/mass spectrometry (LC/MS). PMID:24937686
Steam-jet Chiller for Army Field Kitchens
2009-08-01
Steam-Jet Test-Loop Schematic A vacuum pump removes air from the entire system on startup, and is occasionally used to expel air during...delivered to the tube and shell condenser. The steam is condensed and drains to the vacuum sump tank. 11 Periodically, the condensate pump ... Vacuum Roughing Pump The condenser must be held at vacuum to prevent air from insulating the condenser tubes or create a back-pressure that would
Energy Conservation: Heating Navy Hangars
1984-07-01
temperature, IF Tf Inside air temperature 1 foot above the floor, OF T. Inside design temperature, IF To Hot water temperature setpoint , OF TON Chiller ...systems capable of optimizing energy usage base-wide. An add-on to an existing large scale EMCS is probably the first preference, followed by single...the building comfort conditions are met during hours of building occupancy. 2. Optimized Start/Stop turns on equipment at the latest possible time and
1987-01-01
e4run stoag :ahbl’ -ss to -ervice the, IDS equipment a-nd1 tho liFr . F)- fencing ;haill bo prov.id-d iroun,! the IDS area with necessary gats nd roa1d I...will provide enhanced and expanded capabilities. The EMCS (with 2,000 points) will control package boilers at 24 locations, one furnace, chiller
System-level Analysis of Chilled Water Systems Aboard Naval Ships
2015-06-24
developed one-dimensional partial differen- tial equation models that simulate time-dependent hy- drodynamics and heat transport in a piping network...Thermal zone extents. 2) Piping path and diameter. 3) Specifications and locations of chillers, heat ex- changers, pumps and valves. The framework of the... pipes and provides boundary conditions for the end of the connecting pipes . Pumps, valves, bends and heat exchangers are such components. These
Performance analysis and optimization of power plants with gas turbines
NASA Astrophysics Data System (ADS)
Besharati-Givi, Maryam
The gas turbine is one of the most important applications for power generation. The purpose of this research is performance analysis and optimization of power plants by using different design systems at different operation conditions. In this research, accurate efficiency calculation and finding optimum values of efficiency for design of chiller inlet cooling and blade cooled gas turbine are investigated. This research shows how it is possible to find the optimum design for different operation conditions, like ambient temperature, relative humidity, turbine inlet temperature, and compressor pressure ratio. The simulated designs include the chiller, with varied COP and fogging cooling for a compressor. In addition, the overall thermal efficiency is improved by adding some design systems like reheat and regenerative heating. The other goal of this research focuses on the blade-cooled gas turbine for higher turbine inlet temperature, and consequently, higher efficiency. New film cooling equations, along with changing film cooling effectiveness for optimum cooling air requirement at the first-stage blades, and an internal and trailing edge cooling for the second stage, are innovated for optimal efficiency calculation. This research sets the groundwork for using the optimum value of efficiency calculation, while using inlet cooling and blade cooling designs. In the final step, the designed systems in the gas cycles are combined with a steam cycle for performance improvement.
NASA Technical Reports Server (NTRS)
Tiwari, S. N.; Manian, S. V. S.
1976-01-01
Various mathematical models for infrared radiation absorption spectra for atmospheric gases are reviewed, and continuous correlations for the total absorptance of a wide band are presented. Different band absorptance correlations were employed in two physically realistic problems (radiative transfer in gases with internal heat source, and heat transfer in laminar flow of absorbing-emitting gases between parallel plates) to study their influence on final radiative transfer results. This information will be applied to the study of atmospheric pollutants by infrared radiation measurement.
NASA Astrophysics Data System (ADS)
Hayat, T.; Ullah, Siraj; Khan, M. Ijaz; Alsaedi, A.; Zaigham Zia, Q. M.
2018-03-01
Here modeling and computations are presented to introduce the novel concept of Darcy-Forchheimer three-dimensional flow of water-based carbon nanotubes with nonlinear thermal radiation and heat generation/absorption. Bidirectional stretching surface induces the flow. Darcy's law is commonly replace by Forchheimer relation. Xue model is implemented for nonliquid transport mechanism. Nonlinear formulation based upon conservation laws of mass, momentum and energy is first modeled and then solved by optimal homotopy analysis technique. Optimal estimations of auxiliary variables are obtained. Importance of influential variables on the velocity and thermal fields is interpreted graphically. Moreover velocity and temperature gradients are discussed and analyzed. Physical interpretation of influential variables is examined.
Experimental and computational analysis of sound absorption behavior in needled nonwovens
NASA Astrophysics Data System (ADS)
Soltani, Parham; Azimian, Mehdi; Wiegmann, Andreas; Zarrebini, Mohammad
2018-07-01
In this paper application of X-ray micro-computed tomography (μCT) together with fluid simulation techniques to predict sound absorption characteristics of needled nonwovens is discussed. Melt-spun polypropylene fibers of different fineness were made on an industrial scale compact melt spinning line. A conventional batt forming-needling line was used to prepare the needled samples. The normal incidence sound absorption coefficients were measured using impedance tube method. Realistic 3D images of samples at micron-level spatial resolution were obtained using μCT. Morphology of fabrics was characterized in terms of porosity, fiber diameter distribution, fiber curliness and pore size distribution from high-resolution realistic 3D images using GeoDict software. In order to calculate permeability and flow resistivity of media, fluid flow was simulated by numerically solving incompressible laminar Newtonian flow through the 3D pore space of realistic structures. Based on the flow resistivity, the frequency-dependent acoustic absorption coefficient of the needled nonwovens was predicted using the empirical model of Delany and Bazley (1970) and its associated modified models. The results were compared and validated with the corresponding experimental results. Based on morphological analysis, it was concluded that for a given weight per unit area, finer fibers yield to presence of higher number of fibers in the samples. This results in formation of smaller and more tortuous pores, which in turn leads to increase in flow resistivity of media. It was established that, among the empirical models, Mechel modification to Delany and Bazley model had superior predictive ability when compared to that of the original Delany and Bazley model at frequency range of 100-5000 Hz and is well suited to polypropylene needled nonwovens.
Laser-absorption sensing of gas composition of products from coal gasification
NASA Astrophysics Data System (ADS)
Jeffries, Jay B.; Sur, Ritobrata; Sun, Kai; Hanson, Ronald K.
2014-06-01
A prototype in-situ laser-absorption sensor for the real-time composition measurement (CO, CH4, H2O and CO2) of synthesis gas products of coal gasification (called here syngas) was designed, tested in the laboratory, and demonstrated during field-measurement campaigns in a pilot-scale entrained flow gasifier at the University of Utah and in an engineering-scale, fluidized-bed transport gasifier at the National Carbon Capture Center (NCCC). The prototype design and operation were improved by the lessons learned from each field test. Laser-absorption measurements are problematic in syngas flows because efficient gasifiers operate at elevated pressures (10-50 atm) where absorption transitions are collision broadened and absorption transitions that are isolated at 1 atm become blended into complex features, and because syngas product streams can contain significant particulate, producing significant non-absorption scattering losses of the transmission of laser light. Thus, the prototype sensor used a new wavelength-scanned, wavelength-modulation spectroscopy strategy with 2f-detection and 1f-normalization (WMS-2f/1f) that can provide sensitive absorption measurements of species with spectra blended by collision broadening even in the presence of large non-absorption laser transmission losses (e.g., particulate scattering, beam steering, etc.). The design of the sensor for detection of CO, CH4, H2O and CO2 was optimized for the specific application of syngas monitoring at the output of large-scale gasifiers. Sensor strategies, results and lessons learned from these field measurement campaigns are discussed.
NASA Technical Reports Server (NTRS)
Faghri, Amir; Swanson, Theodore D.
1989-01-01
The numerical and experimental analysis of a thin liquid film on a rotating and a stationary disk related to the development of an absorber unit for a high capacity spacecraft absorption cooling system, is described. The creation of artificial gravity by the use of a centrifugal field was focused upon in this report. Areas covered include: (1) One-dimensional computation of thin liquid film flows; (2) Experimental measurement of film height and visualization of flow; (3) Two-dimensional computation of the free surface flow of a thin liquid film using a pressure optimization method; (4) Computation of heat transfer in two-dimensional thin film flow; (5) Development of a new computational methodology for the free surface flows using a permeable wall; (6) Analysis of fluid flow and heat transfer in a thin film in the presence and absence of gravity; and (7) Comparison of theoretical prediction and experimental data. The basic phenomena related to fluid flow and heat transfer on rotating systems reported here can also be applied to other areas of space systems.
NASA Technical Reports Server (NTRS)
Diskin, Glenn S.; Lempert, Walter R.; Miles, Richard B.; Kumar, Vinod; Glesk, Ivan
1991-01-01
Two flow visualization techniques, i.e., simultaneous two-dimensional fluorescence imaging of H2 and O2 in a diffusion flame, and quasi-linear fluorescence imaging of O2, are presented. The first uses an injection-locked argon-fluoride excimer laser and a partial overlap of a two-photon ground state absorption in H2 with a single photon absorption from a vibrational level in O2. The second uses a simple, high-intensity ultraviolet flashlamp which provides a flux of photons in the 180-195 nm range, sufficient to produce a quasi-one-dimensional fluorescence image of hot/room temperature oxygen. Both techniques do not require that a seed material be introduced into the flow, they can image major flow constituents, and provide an instantaneous snapshot of the flow.
Yeung, E.S.; Woodruff, S.D.
1984-06-19
A refractive index and absorption detector are disclosed for liquid chromatography. It is based in part on a Fabry-Perot interferometer and is used for the improved detection of refractive index and absorption. It includes a Fabry-Perot interferometer having a normally fixed first partially reflecting mirror and a movable second partially reflecting mirror. A chromatographic flow-cell is positioned between the mirrors along the optical axis of a monochromatic laser beam passing through the interferometer. A means for deriving information about the interference fringes coming out of the interferometer is used with a mini-computer to compute the refractive index of the specimen injected into the flow cell. The minicomputer continuously scans the interferometer for continuous refractive index readings and outputs the continuous results of the scans on a chart recorder. The absorption of the specimen can concurrently be scanned by including a second optical path for an excitation laser which will not interfere with the first laser, but will affect the specimen so that absorption properties can be detected. By first scanning for the refractive index of the specimen, and then immediately adding the excitation laser and subsequently scanning for the refractive index again, the absorption of the specimen can be computed and recorded. 10 figs.
Yeung, Edward S.; Woodruff, Steven D.
1984-06-19
A refractive index and absorption detector for liquid chromatography. It is based in part on a Fabry-Perot interferometer and is used for the improved detection of refractive index and absorption. It includes a Fabry-Perot interferometer having a normally fixed first partially reflecting mirror and a movable second partially reflecting mirror. A chromatographic flow-cell is positioned between the mirrors along the optical axis of a monochromatic laser beam passing through the interferometer. A means for deriving information about the interference fringes coming out of the interferometer is used with a mini-computer to compute the refractive index of the specimen injected into the flow cell. The minicomputer continuously scans the interferometer for continuous refractive index readings and outputs the continuous results of the scans on a chart recorder. The absorption of the specimen can concurrently be scanned by including a second optical path for an excitation laser which will not interfere with the first laser, but will affect the specimen so that absorption properties can be detected. By first scanning for the refractive index of the specimen, and then immediately adding the excitation laser and subsequently scanning for the refractive index again, the absorption of the specimen can be computed and recorded.
Space Launch System Base Heating Test: Tunable Diode Laser Absorption Spectroscopy
NASA Technical Reports Server (NTRS)
Parker, Ron; Carr, Zak; MacLean, Matthew; Dufrene, Aaron; Mehta, Manish
2016-01-01
This paper describes the Tunable Diode Laser Absorption Spectroscopy (TDLAS) measurement of several water transitions that were interrogated during a hot-fire testing of the Space Launch Systems (SLS) sub-scale vehicle installed in LENS II. The temperature of the recirculating gas flow over the base plate was found to increase with altitude and is consistent with CFD results. It was also observed that the gas above the base plate has significant velocity along the optical path of the sensor at the higher altitudes. The line-by-line analysis of the H2O absorption features must include the effects of the Doppler shift phenomena particularly at high altitude. The TDLAS experimental measurements and the analysis procedure which incorporates the velocity dependent flow will be described.
NASA Astrophysics Data System (ADS)
Qayyum, Sajid; Hayat, Tasawar; Alsaedi, Ahmed
Nonlinear thermal radiation and chemical reaction in magnetohydrodynamic (MHD) flow of third grade nanofluid over a stretching sheet with variable thickness are addressed. Heat generation/absorption and nonlinear convection are considered. The sheet moves with nonlinear velocity. Sheet is convectively heated. In addition zero mass flux condition for nanoparticle concentration is imposed. Results for velocity, temperature, concentration, skin friction and local Nusselt number are presented and examined. It is found that velocity and boundary layer thickness are increasing for Reynolds number. Temperature is a increasing function of the heat generation/absorption parameter while it causes a decrease in the heat transfer rate. Moreover effect of Brownian motion and chemical reaction on the concentration are quite reverse.
High Amplitude Acoustic Behavior of a Slit-Orifice Backed by a Cavity
NASA Technical Reports Server (NTRS)
Ahuja, K. K.; Gaeta, R. J., Jr.; DAgostino, M.; Jones, Mike (Technical Monitor)
2000-01-01
The objective of the study reported here was to acquire detailed acoustic data and limited and flow visualization data for numerical validation a new model of sound absorption by a very narrow rectangular slit backed by a cavity. The sound absorption model is being developed by Dr. C. K. W. Tam of Florida State University. This report documents normal incidence impedance measurements of a singular rectangular slit orifice with no mean flow. All impedance measurements are made within a 1.12 inch (28.5 mm) diameter impedance tube using the two-microphone method for several frequencies in the range 1000-6000Hz and incident sound pressure levels in the range 130 - 150 dB. In the interest of leaving the analysis of the data to the developers of more advanced analytical and computational models of sound absorption by narrow slits, we have refrained from giving our own explanations of the observed results, although many of the observed results can be explained using the classical explanations of sound absorption by orifices.
High Amplitude Acoustic Behavior of a Slit-Orifice Backed by a Cavity
NASA Technical Reports Server (NTRS)
Ahuja, K. K.; Gaeta, R. J., Jr.; DAgostino, M.
2000-01-01
The objective of this study was to acquire detailed acoustic data and limited flow visualization data for numerical validation of a new model of sound absorption by a very narrow rectangular slit backed by a cavity. The sound absorption model is that being developed by Dr. C. K. W. Tam of Florida State University. This report documents normal incidence impedance measurements of a singular rectangular slit orifice with no mean flow. All impedance measurements are made within a 1.12 inch (28.5 mm) diameter impedance tube using the two-microphone method for several frequencies in the range 1000 - 6000Hz and incident sound pressure levels in the range 130 - 150 dB. In the interest of leaving the analysis of the data to the developers of more advanced Analytical and computational models of sound absorption by narrow slits, we authors have refrained from giving our own explanations of the observed results, although many of the observed results can be explained using the classical understanding of sound absorption by orifices.
Measurement of transient gas flow parameters by diode laser absorption spectroscopy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bolshov, M A; Kuritsyn, Yu A; Liger, V V
2015-04-30
An absorption spectrometer based on diode lasers is developed for measuring two-dimension maps of temperature and water vapour concentration distributions in the combustion zones of two mixing supersonic flows of fuel and oxidiser in the single run regime. The method of measuring parameters of hot combustion zones is based on detection of transient spectra of water vapour absorption. The design of the spectrometer considerably reduces the influence of water vapour absorption along the path of a sensing laser beam outside the burning chamber. The optical scheme is developed, capable of matching measurement results in different runs of mixture burning. Amore » new algorithm is suggested for obtaining information about the mixture temperature by constructing the correlation functions of the experimental spectrum with those simulated from databases. A two-dimensional map of temperature distribution in a test chamber is obtained for the first time under the conditions of plasma-induced combusion of the ethylene – air mixture. (laser applications and other topics in quantum electronics)« less
Tunable diode laser measurements of HO2NO2 absorption coefficients near 12.5 microns
NASA Technical Reports Server (NTRS)
May, R. D.; Molina, L. T.; Webster, C. R.
1988-01-01
A tunable diode laser spectrometer has been used to measure absorption coefficients of peroxynitric acid (HO2NO2) near the 803/cm Q branch. HO2NO2 concentrations in a low-pressure flowing gas mixture were determined from chemical titration procedures and UV absorption spectroscopy. The diode laser measured absorption coefficients, at a spectral resolution of better than 0.001/cm, are about 10 percent larger than previous Fourier transform infrared measurements made at a spectral resolution of 0.06/cm.
Central Plant Optimization for Waste Energy Reduction (CPOWER)
2016-12-01
data such as windspeed and solar radiation is recorded in CPOWER. For these periods, the following data fields from the CPOWER database and the weather...The solar radiation data did not appear reliable in the weather dataset for the location, and hence we did not use this. The energy consumption...that several factors affect the total energy consumption of the chiller plant and additional data and additional factors (e.g., solar insolation) may be
Direct Digital Control of HVAC (Heating, Ventilating, and Air Conditioning).
1985-01-01
controller func- tions such as time-of-day, economizer cycles, reset, load shedding, chiller optimization , VAV fan synchronization, and optimum start/stop...control system such as that illustrated in Fig- urc 4. Data on setpoints , reset schedules, and event timing, such as that presented in Figure 6, are...program code (Figure 7). In addition to the control logic, setpoint and other data are readily available. Program logi:, setpoint and schedule data, and
AGOR 28: SIO Shipyard Representative Bi-Weekly Progress Report
2015-01-16
Crane FAT at Sherwood, OR iii. Design Review at Anacortes 2. The following Shipyard Question Submittals were reviewed and commented on: No...include the two Chiller units and the two 100-kw chill water heaters for HVAC winter operation. Report Documentation Page Form ApprovedOMB No. 0704...MLV HVAC Room Foc’sle Deck – Partial installation only in area where machinery has been placed. Most of the overhead and bulkheads have no
Interband cascade (IC) photovoltaic (PV) architecture for PV devices
Yang, Rui Q.; Tian, Zhaobing; Mishima, Tetsuya D.; Santos, Michael B.; Johnson, Matthew B.; Klem, John F.
2015-10-20
A photovoltaic (PV) device, comprising a PV interband cascade (IC) stage, wherein the IC PV stage comprises an absorption region with a band gap, the absorption region configured to absorb photons, an intraband transport region configured to act as a hole barrier, and an interband tunneling region configured to act as an electron barrier. An IC PV architecture for a photovoltaic device, the IC PV architecture comprising an absorption region, an intraband transport region coupled to the absorption region, and an interband tunneling region coupled to the intraband transport region and to the adjacent absorption region, wherein the absorption region, the intraband transport region, and the interband tunneling region are positioned such that electrons will flow from the absorption region to the intraband transport region to the interband tunneling region.
Thermal Nonequilibrium in Hypersonic Separated Flow
2014-12-22
flow duration and steadiness. 15. SUBJECT TERMS Hypersonic Flowfield Measurements, Laser Diagnostics of Gas Flow, Laser Induced...extent than the NS computation. While it would be convenient to believe that the more physically realistic flow modeling of the DSMC gas - surface...index and absorption coefficient. Each of the curves was produced assuming a 0.5 % concentration of lithium at the Condition A nozzle exit conditions
Axisymmetric flow of Casson fluid by a swirling cylinder
NASA Astrophysics Data System (ADS)
Javed, Muhammad Faisal; Khan, Muhammad Imran; Khan, Niaz Bahadur; Muhammad, Riaz; Rehman, Muftooh Ur; Khan, Sajjad Wali; Khan, Tufail A.
2018-06-01
The present communication aims to investigate the influence of heat generation/absorption on axisymmetric Casson liquid flow over a stretched cylinder. Flow is caused due to torsional motion of cylinder. The governing physical problem is modelled and transferred into set of coupled nonlinear ordinary differential equations. These equations are solved numerically using built-in-Shooting method. Influence of sundry variables on the swirling velocity, temperature, coefficient of skin friction and heat transfer rate are computed and analyzed in a physical manner. Magnitude of axial skin friction is enhances for larger Reynold number and magnetic parameter while local Nusselt number decays with the enhancement of Casson parameter, heat generation/absorption and magnetic parameter. Comparison with already existing results is also given in the limiting case.
Nonequilibrium radiation and chemistry models for aerocapture vehicle flowfields, volume 3
NASA Technical Reports Server (NTRS)
Carlson, Leland A.
1991-01-01
The computer programs developed to calculate the shock wave precursor and the method of using them are described. This method calculated the precursor flow field in a nitrogen gas including the effects of emission and absorption of radiation on the energy and composition of gas. The radiative transfer is calculated including the effects of absorption and emission through the line as well as the continuum process in the shock layer and through the continuum processes only in the precursor. The effects of local thermodynamic nonequilibrium in the shock layer and precursor regions are also included in the radiative transfer calculations. Three computer programs utilized by this computational scheme to calculate the precursor flow field solution for a given shock layer flow field are discussed.
Parametric measurements of the effect of in-duct orifice edge shape on its noise damping performance
NASA Astrophysics Data System (ADS)
Ji, Chenzhen; Zhao, Dan; Han, Nuomin; Li, Jing
2016-12-01
Acoustic liners perforated with thousands of millimeter-size orifices are widely used in aero-engines and gas turbine engines as an effective noise damper. In this work, experimental investigations of the acoustic damping effect of in-duct perforated orifices are performed on a cold-flow pipe. A mean flow (also known as bias flow) is applied and its flow rate is variable. Emphasis is placed on the effect of the orifice edge shape. For this, 16 in-duct orifices with different edge shapes and porosities are designed and manufactured by using 3D printing technology and conventional laser cutting technique. The damping effect of these in-duct orifices is characterized by using power absorption coefficient Δ and reflection coefficient χ from 100 to 1000 Hz. The performances of these orifices are found to be either improved or deteriorated, depending on (1) edge shape, (2) the ratio T/d of orifice thickness to its diameter, (3) the bias flow Mach number, (4) downstream pipe length Ld and (5) porosity η via varying either the number N or surface area Ao of the orifices. In addition, modifying orifice edge does not lead to an increase of power absorption at lower frequency (⩽ 700 Hz). However, as the frequency is increased, the orifice with square (S-type) edge is found to be associated with 10 percent more power absorption. It is interesting to find that T/d over the tested range (≤ 0.5) has little influence on its damping capacity. However, the mean bias flow Mach number Ma and porosity η are shown to play critical roles on determining the noise damping performance of these orifices. Maximum power absorption Δmax is found to occur at Ma ≈ 0.018, while the optimum porosity corresponding to Δmax is approximately 7 percent. The present parametric measurements shed light on the roles of orifice edge shape, porosity and mean flow on its noise damping capacity, and facilitate the design of effective perforated liners.
Effective flow resistivity of highway pavements.
Rochat, Judith L; Read, David R
2013-12-01
In the case of highway traffic noise, propagating sound is influenced by the ground over which it travels, whether it is the pavement itself or the ground between the highway and nearby communities. Properly accounting for ground type in modeling can increase accuracy in noise impact determinations and noise abatement design. Pavement-specific effective flow resistivity values are being investigated for inclusion in the Federal Highway Administration Traffic Noise Model, which uses these values in the sound propagation algorithms and currently applies a single effective flow resistivity value to all pavement. Pavement-specific effective flow resistivity values were obtained by applying a modified version of the American National Standards Institute S1.18 standard. The data analysis process was tailored to allow for increased sensitivity and extraction of effective flow resistivity values for a broad range of pavements (sound absorptive to reflective). For porous pavements (sound absorptive), it was determined that examination of the measured data can reveal influence from an underlying structure. Use of such techniques can aid in the design of quieter pavements.
Advanced Diagnostics for Reacting Flows
1993-11-24
time) Dr. J. Seitzman (25% time) Dr. D. Baer (25% time) 4.2 Graduate Research Assistants Tim Birbeck Renato Cedolin (50% time) Andrew Chang Paul...terms of the unsaturated absorption coefficient and an intensity-dependent factor by the relation 4 k,(vo) = ko (vo) 1 + • (8) In the theoretical...variation of the 1.0, the effective saturated absorption coefficient is spectral absorption coefficient that is relative to the 35% (k,/ ko = 0.65) and 44
Fluid mechanics relevant to flow through pretreatment of cellulosic biomass.
Archambault-Léger, Véronique; Lynd, Lee R
2014-04-01
The present study investigates fluid mechanical properties of cellulosic feedstocks relevant to flow through (FT) pretreatment for biological conversion of cellulosic biomass. The results inform identifying conditions for which FT pretreatment can be implemented in a practical context. Measurements of pressure drop across packed beds, viscous compaction and water absorption are reported for milled and not milled sugarcane bagasse, switchgrass and poplar, and important factors impacting viscous flow are deduced. Using biomass knife-milled to pass through a 2mm sieve, the observed pressure drop was highest for bagasse, intermediate for switchgrass and lowest for poplar. The highest pressure drop was associated with the presence of more fine particles, greater viscous compaction and the degree of water absorption. Using bagasse without particle size reduction, the instability of the reactor during pretreatment above 140kg/m(3) sets an upper bound on the allowable concentration for continuous stable flow. Copyright © 2014. Published by Elsevier Ltd.
NASA Technical Reports Server (NTRS)
Jiang, Naibo; Halls, Benjamin R.; Stauffer, Hans U.; Roy, Sukesh; Danehy, Paul M.; Gord, James R.
2016-01-01
Selective Two-Photon Absorptive Resonance Femtosecond-Laser Electronic-Excitation Tagging (STARFLEET), a non-seeded ultrafast-laser-based velocimetry technique, is demonstrated in reactive and non-reactive flows. STARFLEET is pumped via a two-photon resonance in N2 using 202.25-nm 100-fs light. STARFLEET greatly reduces the per-pulse energy required (30 µJ/pulse) to generate the signature FLEET emission compared to the conventional FLEET technique (1.1 mJ/pulse). This reduction in laser energy results in less energy deposited in the flow, which allows for reduced flow perturbations (reactive and non-reactive), increased thermometric accuracy, and less severe damage to materials. Velocity measurements conducted in a free jet of N2 and in a premixed flame show good agreement with theoretical velocities and further demonstrate the significantly less-intrusive nature of STARFLEET.
Methods and systems for detecting gas flow by photoacoustic signal generation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Choudhury, Niloy; Challener, William Albert
A method for the detection of a gas flowing from a location in a structure is described. A hollow-core optical fiber is placed in a position adjacent the structure. The fiber includes a sound-conductive cladding layer; and further includes at least one aperture extending into its cross-sectional diameter. A beam of pulsed, optical is transmitted into the fiber with a tunable laser. The optical energy is characterized by a wavelength that can be absorbed by the gas that flows into the fiber through the aperture. This causes a temperature fluctuation in the region of gas absorption, which in turn generatesmore » an acoustic wave in the absorption region. The acoustic wave travels through the cladding layer, and can be detected with a microphone, so as to provide the location of gas flow, based on the recorded position and movement of the acoustic wave. A related system is also described.« less
NASA Astrophysics Data System (ADS)
Khan, Masood; Ahmad, Latif; Gulzar, M. Mudassar
2018-03-01
The impact of temperature dependent thermal conductivity and convective surface conditions on unsteady 3D Sisko nanofluid flow over a stretching surface is studied in the presence of heat generation/absorption and magnetic field. The numerical solution of nonlinear coupled equations has been carried out to explore the properties of different physical profiles of the fluid flow with varying of parameters. Specifically, the application of generalized Biot numbers and heat generation/absorption parameter in the sketching of temperature and concentration profiles are explored. The effect of all three parameters is noticed in the increasing order for shear thinning (0 < n < 1) and for shear thickening (n > 1) fluids. Moreover, the influence of Biot number γ1 on heat and mass transfer rates, are found in the enhancement and diminishing conducts respectively, in both cases of shear thinning as well as shear thickening fluids and a reverse trend is observed with the variation of Biot number γ2 . Additionally, the present results are validated through skin friction, heat and mass transfer rate values with the comparable values in the existing previous values.
Helium retention and Hydrogen absorption in FLiRE
NASA Astrophysics Data System (ADS)
Schultz, Benjamin
2005-10-01
The FLiRE (Flowing Lithium Retention Experiment) facility consists of a flow loop which contains a two sections to observe flow along ramps in an upper chamber. As the Li exits the upper chamber it makes a vacuum seal isolation of the upper chamber from a lower one where thermal desporption spectroscopy can take place. By applying an ion beam or a plasma pulse to the open-channel Li flow on the ramp, studies can be made of He and H retention by measuring the partial pressure of He in the lower TDS chamber. Previous studies have shown about a 1% to 2% retention of He over a time scale sufficient to exit a potential flowing Li-walled reactor. The significance of such a result is very high and needs to be verified. It is possible that He implanted in the ramp before flow was initiated was absorbed leading to the observed increase. The experiment has been altered to address this and other concerns. Research on hydrogen absorption in liquid lithium exposed to hydrogen plasma has also been conducted. Overall results and their implications towards large scale fusion reactors are given.
Sutherland, John C.
2017-04-15
Linear dichroism provides information on the orientation of chromophores part of, or bound to, an orientable molecule such as DNA. For molecular alignment induced by hydrodynamic shear, the principal axes orthogonal to the direction of alignment are not equivalent. Thus, the magnitude of the flow-induced change in absorption for light polarized parallel to the direction of flow can be more than a factor of two greater than the corresponding change for light polarized perpendicular to both that direction and the shear axis. The ratio of the two flow-induced changes in absorption, the dichroic increment ratio, is characterized using the orthogonalmore » orientation model, which assumes that each absorbing unit is aligned parallel to one of the principal axes of the apparatus. The absorption of the alienable molecules is characterized by components parallel and perpendicular to the orientable axis of the molecule. The dichroic increment ratio indicates that for the alignment of DNA in rectangular flow cells, average alignment is not uniaxial, but for higher shear, as produced in a Couette cell, it can be. The results from the simple model are identical to tensor models for typical experimental configuration. Approaches for measuring the dichroic increment ratio with modern dichrometers are further discussed.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sutherland, John C.
Linear dichroism provides information on the orientation of chromophores part of, or bound to, an orientable molecule such as DNA. For molecular alignment induced by hydrodynamic shear, the principal axes orthogonal to the direction of alignment are not equivalent. Thus, the magnitude of the flow-induced change in absorption for light polarized parallel to the direction of flow can be more than a factor of two greater than the corresponding change for light polarized perpendicular to both that direction and the shear axis. The ratio of the two flow-induced changes in absorption, the dichroic increment ratio, is characterized using the orthogonalmore » orientation model, which assumes that each absorbing unit is aligned parallel to one of the principal axes of the apparatus. The absorption of the alienable molecules is characterized by components parallel and perpendicular to the orientable axis of the molecule. The dichroic increment ratio indicates that for the alignment of DNA in rectangular flow cells, average alignment is not uniaxial, but for higher shear, as produced in a Couette cell, it can be. The results from the simple model are identical to tensor models for typical experimental configuration. Approaches for measuring the dichroic increment ratio with modern dichrometers are further discussed.« less
Sutherland, John C
2017-04-15
Linear dichroism provides information on the orientation of chromophores part of, or bound to, an orientable molecule such as DNA. For molecular alignment induced by hydrodynamic shear, the principal axes orthogonal to the direction of alignment are not equivalent. Thus, the magnitude of the flow-induced change in absorption for light polarized parallel to the direction of flow can be more than a factor of two greater than the corresponding change for light polarized perpendicular to both that direction and the shear axis. The ratio of the two flow-induced changes in absorption, the dichroic increment ratio, is characterized using the orthogonal orientation model, which assumes that each absorbing unit is aligned parallel to one of the principal axes of the apparatus. The absorption of the alienable molecules is characterized by components parallel and perpendicular to the orientable axis of the molecule. The dichroic increment ratio indicates that for the alignment of DNA in rectangular flow cells, average alignment is not uniaxial, but for higher shear, as produced in a Couette cell, it can be. The results from the simple model are identical to tensor models for typical experimental configurations. Approaches for measuring the dichroic increment ratio with modern dichrometers are discussed. Copyright © 2017. Published by Elsevier Inc.
Optofluidic-Tunable Color Filters And Spectroscopy Based On Liquid-Crystal Microflows
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cuennet, J. G.; Vasdekis, Andreas E.; Psaltis, D.
The integration of color filters with microfluidics has attracted substantial attention in recent years, for on-chip absorption, fluorescence, or Raman analysis. We describe such tunable filters based on the micro-flow of liquid crystals. The filter operation is based on the wavelength dependent liquid crystal birefringence that can be tuned by modifying the flow velocity field in the microchannel. The latter is possible both temporally and spatially by varying the inlet pressure and the channel geometry respectively. We explored the use of these optofluidic filters for on-chip absorption spectroscopy; by integrating the distance dependent color filter with a dye-filled micro-channel, themore » absorption spectrum of a dye could be measured. Liquid crystal microflows simplify substantially the optofluidic integration, actuation and tuning of color filters for lab-on-a-chip spectroscopic applications.« less
NASA Astrophysics Data System (ADS)
Hayat, Tasawar; Qayyum, Sumaira; Alsaedi, Ahmed; Ahmad, Bashir
2018-03-01
Flow of second grade fluid by a rotating disk with heat and mass transfer is discussed. Additional effects of heat generation/absorption are also analyzed. Flow is also subjected to homogeneous-heterogeneous reactions. The convergence of computed solution is assured through appropriate choices of initial guesses and auxiliary parameters. Investigation is made for the effects of involved parameters on velocities (radial, axial, tangential), temperature and concentration. Skin friction and Nusselt number are also analyzed. Graphical results depict that an increase in viscoelastic parameter enhances the axial, radial and tangential velocities. Opposite behavior of temperature is observed for larger values of viscoelastic and heat generation/absorption parameters. Concentration profile is increasing function of Schmidt number, viscoelastic parameter and heterogeneous reaction parameter. Magnitude of skin friction and Nusselt number are enhanced for larger viscoelastic parameter.
Evaluation of Renal Blood Flow and Oxygenation in CKD Using Magnetic Resonance Imaging.
Khatir, Dinah S; Pedersen, Michael; Jespersen, Bente; Buus, Niels H
2015-09-01
Animal studies suggest that progression of chronic kidney disease (CKD) is related to renal hypoxia. With renal blood supply determining oxygen delivery and sodium absorption being the main contributor to oxygen consumption, we describe the relationship between renal oxygenation, renal artery blood flow, and sodium absorption in patients with CKD and healthy controls. Cross-sectional study. 62 stable patients with CKD stages 3 to 4 (mean age, 61±13 [SD] years) and 24 age- and sex-matched controls. CKD versus control status. Renal artery blood flow, tissue oxygenation (relative changes in deoxyhemoglobin concentration of the renal medulla [MR2*] and cortex [CR2*]), and sodium absorption. Renal artery blood flow was determined by phase-contrast magnetic resonance imaging (MRI); MR2* and CR2* were determined by blood oxygen level-dependent MRI. Ultrafiltered and reabsorbed sodium were determined from measured glomerular filtration rate (mGFR) and 24-hour urine collections. mGFR in patients was 37% that of controls (36±15 vs 97±23 mL/min/1.73 m(2); P < 0.001), and reabsorbed sodium was 37% that of controls (6.9 vs 19.1 mol/24 h; P < 0.001). Single-kidney patient renal artery blood flow was 72% that of controls (319 vs 443 mL/min; P < 0.001). Glomerular filtration fraction was 9% in patients and 18% in controls (P < 0.001). Patients and controls had similar CR2* (13.4 vs 13.3 s(-1)) and medullary MR2* (26.4 vs 26.5 s(-1)) values. Linear regression analysis demonstrated no associations between R2* and renal artery blood flow or sodium absorption. Increasing arterial blood oxygen tension by breathing 100% oxygen had very small effects on CR2*, but reduced MR2* in both groups. Only renal artery blood flow was determined and thus regional perfusion could not be related to CR2* or MR2*. In CKD, reductions of mGFR and reabsorbed sodium are more than double that of renal artery blood flow, whereas cortical and medullary oxygenation are within the range of healthy persons. Reduction in glomerular filtration fraction may prevent renal hypoxia in CKD. Copyright © 2015 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Martin, Marcel Nations; Chang, Leyen S.; Jeffries, Jay B.; Hanson, Ronald K.; Nawaz, Anuscheh; Taunk, Jaswinder S.; Driver, David M.; Raiche, George
2013-01-01
A tunable diode laser sensor was designed for in situ monitoring of temperature in the arc heater of the NASA Ames IHF arcjet facility (60 MW). An external cavity diode laser was used to generate light at 777.2 nm and laser absorption used to monitor the population of electronically excited oxygen atoms in an air plasma flow. Under the assumption of thermochemical equilibrium, time-resolved temperature measurements were obtained on four lines-of-sight, which enabled evaluation of the temperature uniformity in the plasma column for different arcjet operating conditions.
Users Guide to Direct Digital Control of Heating, Ventilating, and Air Conditioning Equipment,
1985-01-01
cycles, reset, load shedding, chiller optimization , VAV fan synchronization, and optimum start/stop. The prospective buyer of a DDC system should...in Fig- ure 4. Data on setpoints , reset schedules, and event timing, such as that presented in Figure 6, are often even more difficult to find. In con...control logic, setpoint and other data are readily available. Program logic, setpoint and schedule data, and other information stored in a DDC unit
Direct Digital Control of HVAC (Heating, Ventilating, and Air Conditioning Equipment (User’s Guide)
1985-01-01
reset, load shedding, chiller optimization , VAV fan synchronization, and optimum start/stop. The prospective buyer of a DDC system should investigate...current and accurate drawings for a conventional, built-up control system such as that illustrated in Fig- ure 4. Data on setpoints , reset schedules, and...are always available in the form of the computer program code (Figure 7). In addition to the control logic, setpoint and other data are readily
2008-04-29
An exhaust hood is necessary for binder removal. Cooling requires a fan at a second speed setpoint . Firing profiles need to be precisely...29,935.06 from Ohio match. Plasmalab 80 Plus Compact etching system (left) and heater/ chiller unit (right). CAHN TherMax 500 High Pressure TGA...the current research is aimed to optimize parameters of the structure, in order to improve the resonant properties of the periodic layered structures
1981-03-01
AD-A B99 054 CONSTRUCTION EN INEERIN RESEARCH LAB (ARMY) CHAMPAIGN IL F/ 9/2 BUILDING LOADS ANALYSIS AND SYSTEM THERMOD NAMICS (BLAST) PROGR...continued. systems , (11) induction unit systems , (12) direct-drive chillers, and (13) purchased steam from utilities. BLAST Version 3.0 also offers the user...their BLAST input. II UNCLASSIFIED SECURITY CLASSIFICATION OF THIS PAGEftin Date Rnerod) FOREWORD This report was prepared for the Air Force Systems
Integration, commissioning, and performance of the UK FMOS spectrograph
NASA Astrophysics Data System (ADS)
Dalton, Gavin B.; Lewis, Ian J.; Tosh, Ian A. J.; Blackburn, Colin; Bonfield, David G.; Brooks, Charles B.; Holmes, Alan R.; Lee, Hanshin; Froud, Tim R.; Akiyama, Masayuki; Tamura, Naoyuki; Takato, Naruhisa
2008-07-01
The UK FMOS spectrograph forms part of Subaru's FMOS multi-object infrared spectroscopy facility. The spectrograph was shipped to Hilo in component form in August of 2007. We describe the integration sequence for the spectrograph, the results of cooldown tests using a new chiller unit fitted to the spectrograph at the telescope, and alignment tests of the spectrograph, gratings and OH-suppression masks. We present the first-light observations for the spectrograph from May 2008.
Project W-320, 241-C-106 sluicing HVAC calculations, Volume 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bailey, J.W.
1998-08-07
This supporting document has been prepared to make the FDNW calculations for Project W-320, readily retrievable. The report contains the following calculations: Exhaust airflow sizing for Tank 241-C-106; Equipment sizing and selection recirculation fan; Sizing high efficiency mist eliminator; Sizing electric heating coil; Equipment sizing and selection of recirculation condenser; Chiller skid system sizing and selection; High efficiency metal filter shielding input and flushing frequency; and Exhaust skid stack sizing and fan sizing.
Cancer Prevention and Control Research Manpower Development
1998-09-01
CA 1984-1985 ASSOCIATE PROFESSOR CLEVELAND CHIROPRACTIC COLLEGE, L.A., CA 1986-1996 CHIROPRACTIC DIRECTOR: CHIRO-MED WEST, L.A., CA 1986-1996 PHYSICAL ...1971. z 3. Shacks, S.J., Chiller, J. and Granger, G.A.: The In Vitro Role of Thymus Dependent Cells in DNA Synthesis and LT Secretion by PHA- Stimulated ...and Physical Activity A. Low fat dietary intake B. Fruits and vegetables C. Obesity D. Physical Activity IX. Summary An overview of the program w
Fluid-film foil bearings control engine heat
NASA Astrophysics Data System (ADS)
O'Connor, Leo
1993-05-01
The state-of-the-art of fluid-film foil bearings and their current and prospective applications are briefly reviewed. In particular, attention is given to the general design of fluid-film foil bearings, the materials used, and bearing performance. The applications discussed include launch vehicle turbopumps, turbines used to cool aircraft cabins, and turbocompressors and turboexpanders used in the processing of cryogenic fluids. Future applications may include turbochargers, textile spindles, cryocoolers, motor blowers, heat pumps, and solar chillers.
Ba, Hoa Van; Park, KyoungMi; Dashmaa, Dashdorj; Hwang, Inho
2014-02-01
The present study demonstrates the effects of different muscle types and chiller ageing periods on the chemical composition, meat quality parameters, sensory characteristics and volatile compounds of Karean native cattle beed. Longissimus dorsi (LD) and Semitendinosus (ST) muscles aged for 7 days and 28 days were used. Moisture, cooking loss, total collagen and Warner-Bratzler shear force (WBSF) values for the ST were higher than the LD muscle regardless of ageing period (P < 0.05). The LD muscle had higher intramuscular fat (IMF) (P < 0.05). Ageing for 28 days decreased WBSF values whereas it increased thiobarbituric acid of both muscles. Moreover, tenderness, juiciness and flavor scores were significantly higher for the LD muscle at both ageing periods. Increased ageing time improved tenderness of both muscles, and increased juiciness of the LD muscle, whereas there was decreased flavor score of ST muscle (P < 0.05). The majority of the volatile compounds formed from the oxidation of lipids showed differences between the two muscles. Ageing for 28 days increased in the amounts of many volatile compounds; however, the amounts of some important volatile compounds were decreased. These results clearly demonstrate that muscle type and ageing have a potential effect on meat quality, sensory characteristics and volatile profile. © 2013 Japanese Society of Animal Science.
Triple loop heat exchanger for an absorption refrigeration system
Reimann, Robert C.
1984-01-01
A triple loop heat exchanger for an absorption refrigeration system is disclosed. The triple loop heat exchanger comprises portions of a strong solution line for conducting relatively hot, strong solution from a generator to a solution heat exchanger of the absorption refrigeration system, conduit means for conducting relatively cool, weak solution from the solution heat exchanger to the generator, and a bypass system for conducting strong solution from the generator around the strong solution line and around the solution heat exchanger to an absorber of the refrigeration system when strong solution builds up in the generator to an undesirable level. The strong solution line and the conduit means are in heat exchange relationship with each other in the triple loop heat exchanger so that, during normal operation of the refrigeration system, heat is exchanged between the relatively hot, strong solution flowing through the strong solution line and the relatively cool, weak solution flowing through the conduit means. Also, the strong solution line and the bypass system are in heat exchange relationship in the triple loop heat exchanger so that if the normal flow path of relatively hot, strong solution flowing from the generator to an absorber is blocked, then this relatively, hot strong solution which will then be flowing through the bypass system in the triple loop heat exchanger, is brought into heat exchange relationship with any strong solution which may have solidified in the strong solution line in the triple loop heat exchanger to thereby aid in desolidifying any such solidified strong solution.
The Work-Related Flow Inventory: Construction and Initial Validation of the WOLF
ERIC Educational Resources Information Center
Bakker, Arnold B.
2008-01-01
The WOrk-reLated Flow inventory (WOLF) measures flow at work, defined as a short-term peak experience characterized by absorption, work enjoyment, and intrinsic work motivation. Results of Study 1 among 7 samples of employees (total N=1346) from different occupational groups offer support for the factorial validity and reliability of the WOLF.…
Flow among Musicians: Measuring Peak Experiences of Student Performers
ERIC Educational Resources Information Center
Sinnamon, Sarah; Moran, Aidan; O'Connell, Michael
2012-01-01
"Flow" is a highly coveted yet elusive state of mind that is characterized by complete absorption in the task at hand as well as by enhanced skilled performance. Unfortunately, because most measures of this construct have been developed in physical activity and sport settings, little is known about the applicability of flow scales to the…
Relaminarization of fluid flows
NASA Technical Reports Server (NTRS)
Narasimha, R.; Sreenivasan, K. R.
1979-01-01
The mechanisms of the relaminarization of turbulent flows are investigated with a view to establishing any general principles that might govern them. Three basic archetypes of reverting flows are considered: the dissipative type, the absorptive type, and the Richardson type exemplified by a turbulent boundary layer subjected to severe acceleration. A number of other different reverting flows are then considered in the light of the analysis of these archetypes, including radial Poiseuille flow, convex boundary layers, flows reverting by rotation, injection, and suction, as well as heated horizontal and vertical gas flows. Magnetohydrodynamic duct flows are also examined. Applications of flow reversion for turbulence control are discussed.
Counter-streaming flows in a giant quiet-Sun filament observed in the extreme ultraviolet
NASA Astrophysics Data System (ADS)
Diercke, A.; Kuckein, C.; Verma, M.; Denker, C.
2018-03-01
Aim. The giant solar filament was visible on the solar surface from 2011 November 8-23. Multiwavelength data from the Solar Dynamics Observatory (SDO) were used to examine counter-streaming flows within the spine of the filament. Methods: We use data from two SDO instruments, the Atmospheric Imaging Assembly (AIA) and the Helioseismic and Magnetic Imager (HMI), covering the whole filament, which stretched over more than half a solar diameter. Hα images from the Kanzelhöhe Solar Observatory (KSO) provide context information of where the spine of the filament is defined and the barbs are located. We apply local correlation tracking (LCT) to a two-hour time series on 2011 November 16 of the AIA images to derive horizontal flow velocities of the filament. To enhance the contrast of the AIA images, noise adaptive fuzzy equalization (NAFE) is employed, which allows us to identify and quantify counter-streaming flows in the filament. We observe the same cool filament plasma in absorption in both Hα and EUV images. Hence, the counter-streaming flows are directly related to this filament material in the spine. In addition, we use directional flow maps to highlight the counter-streaming flows. Results: We detect counter-streaming flows in the filament, which are visible in the time-lapse movies in all four examined AIA wavelength bands (λ171 Å, λ193 Å, λ304 Å, and λ211 Å). In the time-lapse movies we see that these persistent flows lasted for at least two hours, although they became less prominent towards the end of the time series. Furthermore, by applying LCT to the images we clearly determine counter-streaming flows in time series of λ171 Å and λ193 Å images. In the λ304 Å wavelength band, we only see minor indications for counter-streaming flows with LCT, while in the λ211 Å wavelength band the counter-streaming flows are not detectable with this method. The diverse morphology of the filament in Hα and EUV images is caused by different absorption processes, i.e., spectral line absorption and absorption by hydrogen and helium continua, respectively. The horizontal flows reach mean flow speeds of about 0.5 km s-1 for all wavelength bands. The highest horizontal flow speeds are identified in the λ171 Å band with flow speeds of up to 2.5 km s-1. The results are averaged over a time series of 90 minutes. Because the LCT sampling window has finite width, a spatial degradation cannot be avoided leading to lower estimates of the flow velocities as compared to feature tracking or Doppler measurements. The counter-streaming flows cover about 15-20% of the whole area of the EUV filament channel and are located in the central part of the spine. Conclusions: Compared to the ground-based observations, the absence of seeing effects in AIA observations reveal counter-streaming flows in the filament even with a moderate image scale of 0. ''6 pixel-1. Using a contrast enhancement technique, these flows can be detected and quantified with LCT in different wavelengths. We confirm the omnipresence of counter-streaming flows also in giant quiet-Sun filaments. A movie associated to Fig. 6 is available at http://https://www.aanda.org
Direct fired absorption machine flue gas recuperator
Reimann, Robert C.; Root, Richard A.
1985-01-01
A recuperator which recovers heat from a gas, generally the combustion gas of a direct-fired generator of an absorption machine. The recuperator includes a housing with liquid flowing therethrough, the liquid being in direct contact with the combustion gas for increasing the effectiveness of the heat transfer between the gas and the liquid.
29 CFR 1910.155 - Scope, application and definitions applicable to this subpart.
Code of Federal Regulations, 2014 CFR
2014-07-01
... moisture absorption (caking) as well as to provide proper flow capabilities. Dry chemical does not include... require formal classroom instruction. (15) Enclosed structure means a structure with a roof or ceiling and... a rigid shell, energy absorption system, and chin strap intended to be worn to provide protection...
29 CFR 1910.155 - Scope, application and definitions applicable to this subpart.
Code of Federal Regulations, 2013 CFR
2013-07-01
... moisture absorption (caking) as well as to provide proper flow capabilities. Dry chemical does not include... require formal classroom instruction. (15) Enclosed structure means a structure with a roof or ceiling and... a rigid shell, energy absorption system, and chin strap intended to be worn to provide protection...
29 CFR 1910.155 - Scope, application and definitions applicable to this subpart.
Code of Federal Regulations, 2011 CFR
2011-07-01
... moisture absorption (caking) as well as to provide proper flow capabilities. Dry chemical does not include... require formal classroom instruction. (15) Enclosed structure means a structure with a roof or ceiling and... a rigid shell, energy absorption system, and chin strap intended to be worn to provide protection...
29 CFR 1910.155 - Scope, application and definitions applicable to this subpart.
Code of Federal Regulations, 2012 CFR
2012-07-01
... moisture absorption (caking) as well as to provide proper flow capabilities. Dry chemical does not include... require formal classroom instruction. (15) Enclosed structure means a structure with a roof or ceiling and... a rigid shell, energy absorption system, and chin strap intended to be worn to provide protection...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fernqvist-Forbes, E.; Linde, B.; Gunnarsson, R.
1988-09-01
We studied the effects of insulin-induced hypoglycemia on the absorption of 10 U /sup 125/I-labeled soluble human insulin injected sc in the thigh in 10 normal subjects. The disappearance of /sup 125/I from the injection site was followed by external gamma-counting. Subcutaneous blood flow (ATBF) was measured concomitantly with the 133Xe washout technique. The plasma glucose nadir (mean, 2.0 +/- 0.1 (+/- SE) mmol/L) occurred at 33 +/- 3 min and resulted in maximal arterial plasma epinephrine concentrations of approximately 6 nmol/L. From 30 min before to 60 min after the glucose nadir the (/sup 125/I)insulin absorption rate was depressedmore » compared to that during normoglycemia. The first order disappearance rate constants were reduced by approximately 50% (P less than 0.01) during the first 30-min interval after the glucose nadir. During the same period ATBF increased by 100% (P less than 0.05). The results suggest that in normal subjects the absorption of soluble insulin from a sc depot is depressed in connection with hypoglycemia, despite considerably elevated ATBF.« less
Study on molecular sieve absorption of ground state HF molecules in a non-chain pulsed HF Laser
NASA Astrophysics Data System (ADS)
Ma, Lianying; Zhou, Songqing; Chao, Huang; Huang, Ke; Zhu, Feng; Luan, Kunpeng; Chen, Hongwei
2017-05-01
This paper describes the principle of non-chain pulsed HF laser, and analyzes the reason why the laser energy dropped severely with the accumulation of shots when the HF laser was in repetitive operation. In order to solve this problem, a molecular sieve absorption device was designed and mounted in the recirculation loop of the HF laser. Measurements of flow velocity indicated that the absorption device would just introduce a small decrease of flow velocity which would not influence the laser operation. Several types of molecular sieve (3A,4A,5A,13X) were used in absorbing experiments and the experiment results inferred that 3A molecular sieve was the most effective sorbent. All the experiments showed that the average drop of the output energy was not more than 5% after 1000 shots at 50Hz/20s. Compared to the energy drop of about 40% without the device, the absorption device could significantly improve the stability of the HF laser output energy and prolong the lifespan of laser medium gases.
Uchiho, Yuichi; Goto, Yusuke; Kamahori, Masao; Aota, Toshimichi; Morisaki, Atsuki; Hosen, Yusuke; Koda, Kimiyoshi
2015-12-11
A far-ultraviolet (FUV)-absorbance detector with a transmission flow cell was developed and applied to detect absorbance of sugars and peptides by HPLC. The main inherent limitation of FUV-absorbance detection is the strong absorptions of solvents and atmospheric oxygen in the optical system as well as dissolved oxygen in the solvent. High absorptivity of the solvent and oxygen decreases transmission-light intensity in the flow cell and hinders the absorbance measurement. To solve the above drawbacks, the transmission-light intensity in the flow cell was increased by introducing a new optical system and a nitrogen-purging unit to remove the atmospheric oxygen. The optical system has a photodiode for detecting the reference light at a position of the minus-first-order diffracted light. In addition, acetonitrile and water were selected as usable solvents because of their low absorptivity in the FUV region. As a result of these implementations, the detectable wavelength of the FUV-absorbance detector (with a flow cell having an effective optical path length of 0.5mm) can be extended down to 175nm. Three sugars (glucose, fructose, and sucrose) were successfully detected with the FUV-absorbance detector. These detection results reveal that the absorption peak of sugar in liquid phase lies at around 178nm. The detection limit (S/N=3) in absorbance with a 0.5-mm flow cell at 180nm was 21μAU, which corresponds to 33, 60 and 60μM (198, 360, and 360pmol) for fructose, glucose, and sucrose, respectively. Also, the peptide Met-enkephalin could be detected with a high sensitivity at 190nm. The estimated detection limit (S/N=3) for Met-enkephalin is 29nM (0.29pmol), which is eight times lower than that at 220nm. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Taniguchi, Masahiko; Hu, Gongfang; Liu, Rui; Du, Hai; Lindsey, Jonathan S.
2018-02-01
Demands in flow cytometry for increased multiplexing (for detection of multiple antigens) and brightness (for detection of rare entities) require new fluorophores (i.e., "colors") with spectrally distinct fluorescence outside the relatively congested visible spectral region. Flow cytometry fluorophores typically must function in aqueous solution upon bioconjugation and ideally should exhibit a host of photophysical features: (i) strong absorption, (ii) sizable Stokes shift, (iii) modest if not strong fluorescence, and (iv) narrow fluorescence band. Tandem dyes have long been pursued to achieve a large effective Stokes shift, increased brightness, and better control over the excitation and emission wavelengths. Here, the attractive photophysical features of chlorophylls and bacteriochlorophylls - Nature's chosen photoactive pigments for photosynthesis - are described with regards to use in flow cytometry. A chlorophyll (or bacteriochlorophyll) constitutes an intrinsic tandem dye given the red (or near-infrared) fluorescence upon excitation in the higher energy ultraviolet (UV) or visible absorption bands (due to rapid internal conversion to the lowest energy state). Synthetic (bacterio)chlorins are available with strong absorption (near-UV molar absorption coefficient ɛ(λexc) 105 M-1cm-1), modest fluorescence quantum yield (Φf = 0.05-0.30), and narrow fluorescence band (10-25 nm) tunable from 600-900 nm depending on synthetic design. The "relative practical brightness" is given by intrinsic brightness [ɛ(λexc) x Φf] times ηf, the fraction of the fluorescence band that is captured by an emission filter in a multicolor experiment. The spectroscopic features of (bacterio)chlorins are evaluated quantitatively to illustrate practical brightness for this novel class of fluorophores in a prospective 8-color panel.
NASA Technical Reports Server (NTRS)
DSa, E. J.; Miller, R. L.; DelCastillo, C.
2003-01-01
The Mississippi River Bight is a highly dynamic region influenced by the seasonally variable outflow from the Mississippi River. In an effort to characterize the distribution of particulate and dissolved organic matter in the region, we conducted a two-year field program in the spring and fall (high and low flow river discharge) of 2000 and 2002. We collected a comprehensive set of bio-optical measurements consisting of vertical profiles (absorption, scattering, chlorophyll fluorescence and radiometry) and discrete measurements (pigment concentrations, particulate and CDOM absorption) that enabled us to obtain better insight into the seasonal and spatial variability of some important biogeochemical parameters. Our field measurements generally showed higher phytoplankton clorophyll concentrations in the plume waters (associated with lower surface salinities) and confirmed the high biological activity abserved in other studies. The seasonal flow of river discharge and advective currents due to wind forcing exerted a strong influence on the biological and optical properties of the region. An examination of absorption at 440 nm by the algal and non-algal fraction of the particulate pool and of CDOM revealed that at nearshore stations, contributions by the non-algal particles were high (about 40%) and decresed with increasing salinities. While CDOM absorption exhibited conservative mixing, its relative contribution to the total absorption was variable. Surface waters at most stations had lower salinities that generalliy increased with dept. Particulate matter and CDOM also decreased with depth as evidenced by absorption and scattering measurements. Good correlations in surface waters between concentrations of particulate and dissolved matter, the inherent optical properties of absorption and ackscattering and remote sensing reflectance values has allowed the development of robust empirical algorithms for phytoplankton chlorophyll and CDOM absorption.
Absorption sensor for CO in combustion gases using 2.3 µm tunable diode lasers
NASA Astrophysics Data System (ADS)
Chao, X.; Jeffries, J. B.; Hanson, R. K.
2009-11-01
Tunable diode laser absorption spectroscopy of CO was studied in the controlled laboratory environments of a heated cell and a combustion exhaust rig. Two absorption lines, R(10) and R(11) in the first overtone band of CO near 2.3 µm, were selected from a HITRAN simulation to minimize interference from water vapor at a representative combustion exhaust temperature (~1200 K). The linestrengths and collision broadening coefficients for these lines were measured in a heated static cell. This database was then used in a comparative study of direct absorption and wavelength-modulation absorption. CO concentration measurements using scanned-wavelength direct absorption (DA) and wavelength modulation with the second-harmonic signal normalized by the first-harmonic signal (WMS-2f/1f) all agreed with those measured by a conventional gas sampling analyzer over the range from <10 ppm to 2.3%. As expected, water vapor was found to be the dominant source of background interference for CO detection in combustion flows at high temperatures. Water absorption was measured to a high spectral resolution within the wavelength region 4295-4301 cm-1 at 1100 K, and shown to produce <10 ppm level interference for CO detection in combustion exhausts at temperatures up to 1200 K. We found that the WMS-2f/1f strategy avoids the need for WMS calibration measurements but requires characterization of the wavelength and injection-current intensity modulation of the specific diode laser. We conclude that WMS-2f/1f using the selected R(10) or R(11) transitions in the CO overtone band holds good promise for sensitive in situ detection of ppm-level CO in combustion flows, with high resistance to interference absorption from H2O.
NASA Astrophysics Data System (ADS)
Giuliano, Michael R.; Prasad, Ajay K.; Advani, Suresh G.
2012-10-01
Lithium-titanate batteries have become an attractive option for battery electric vehicles and hybrid electric vehicles. In order to maintain safe operating temperatures, these batteries must be actively cooled during operation. Liquid-cooled systems typically employed for this purpose are inefficient due to the parasitic power consumed by the on-board chiller unit and the coolant pump. A more efficient option would be to circulate ambient air through the battery bank and directly reject the heat to the ambient. We designed and fabricated such an air-cooled thermal management system employing metal-foam based heat exchanger plates for sufficient heat removal capacity. Experiments were conducted with Altairnano's 50 Ah cells over a range of charge-discharge cycle currents at two air flow rates. It was found that an airflow of 1100 mls-1 per cell restricts the temperature rise of the coolant air to less than 10 °C over ambient even for 200 A charge-discharge cycles. Furthermore, it was shown that the power required to drive the air through the heat exchanger was less than a conventional liquid-cooled thermal management system. The results indicate that air-cooled systems can be an effective and efficient method for the thermal management of automotive battery packs.
Emergency membrane contactor based absorption system for ammonia leaks in water treatment plants.
Shao, Jiahui; Fang, Xuliang; He, Yiliang; Jin, Qiang
2008-01-01
Abstract Because of the suspected health risks of trihalomethanes (THMs), more and more water treatment plants have replaced traditional chlorine disinfection process with chloramines but often without the proper absorption system installed in the case of ammonia leaks in the storage room. A pilot plant membrane absorption system was developed and installed in a water treatment plant for this purpose. Experimentally determined contact angle, surface tension, and corrosion tests indicated that the sulfuric acid was the proper choice as the absorbent for leaking ammonia using polypropylene hollow fiber membrane contactor. Effects of several operating conditions on the mass transfer coefficient, ammonia absorption, and removal efficiency were examined, including the liquid concentration, liquid velocity, and feed gas concentration. Under the operation conditions investigated, the gas absorption efficiency over 99.9% was achieved. This indicated that the designed pilot plant membrane absorption system was effective to absorb the leaking ammonia in the model storage room. The removal rate of the ammonia in the model storage room was also experimentally and theoretically found to be primarily determined by the ammonia suction flow rate from the ammonia storage room to the membrane contactor. The ammonia removal rate of 99.9% was expected to be achieved within 1.3 h at the ammonia gas flow rate of 500 m3/h. The success of the pilot plant membrane absorption system developed in this study illustrated the potential of this technology for ammonia leaks in water treatment plant, also paved the way towards a larger scale application.
Water quality monitor for recovered spacecraft water
NASA Technical Reports Server (NTRS)
Ejzak, E. M.; Price, D. F.
1985-01-01
A total organic carbon (TOC) analysis system based on ultraviolet absorption is described. The equation for measuring the intensity of the absorbed radiation of the organic substances, which is based on the Lambert-Beer law, is given; the intensity of the absorption is proportional to the concentration of the solution. The operation of the UV-Absorption analyzer, which utilizes a split beam, two wvaelength method, is studied. The influences of the cell path length and specific compounds in the solution flowing through the cell on absorbances is discussed. The performance and response of the analyzer is evaluated; good correlation is observed between the absorption value and TOC. The advantage of the UV-Absorption as compared with the UV-Oxidation are examined.
2012-03-01
Revit object IFCExportType IFCExportAs Radiator Radiator IfcSpaceHeaterType Pump Circulator IfcPumpType Boiler Water IfcBoilerType Fan VaneAxial...modeling is assumed to be a traditional water-based system comprised of boilers and fan coil units (heating) and chillers and air handling units...the properties that a particular engineer would want to specify as part of the BIM model. For instance, the default pump families in Revit do not
Woda, Craig B; Miyawaki, Nobuyuki; Ramalakshmi, Santhanam; Ramkumar, Mohan; Rojas, Raul; Zavilowitz, Beth; Kleyman, Thomas R; Satlin, Lisa M
2003-10-01
High urinary flow rates stimulate K secretion in the fully differentiated but not neonatal or weanling rabbit cortical collecting duct (CCD). Both small-conductance secretory K and high-conductance Ca2+/stretch-activated maxi-K channels have been identified in the apical membrane of the mature CCD by patch-clamp analysis. We reported that flow-stimulated net K secretion in the adult rabbit CCD is 1) blocked by TEA and charybdotoxin, inhibitors of intermediate- and high-conductance (maxi-K) Ca2+-activated K channels, and 2) associated with increases in net Na absorption and intracellular Ca2+ concentration ([Ca2+]i). The present study examined whether the absence of flow-stimulated K secretion early in life is due to a 1) limited flow-induced rise in net Na absorption and/or [Ca2+]i and/or 2) paucity of apical maxi-K channels. An approximately sixfold increase in tubular fluid flow rate in CCDs isolated from 4-wk-old rabbits and microperfused in vitro led to an increase in net Na absorption and [Ca2+]i, similar in magnitude to the response observed in 6-wk-old tubules, but it failed to generate an increase in net K secretion. By 5 wk of age, there was a small, but significant, flow-stimulated rise in net K secretion that increased further by 6 wk of life. Luminal perfusion with iberiotoxin blocked the flow stimulation of net K secretion in the adult CCD, confirming the identity of the maxi-K channel in this response. Maxi-K channel alpha-subunit message was consistently detected in single CCDs from animals >/=4 wk of age by RT-PCR. Indirect immunofluorescence microscopy using antibodies directed against the alpha-subunit revealed apical labeling of intercalated cells in cryosections from animals >/=5 wk of age; principal cell labeling was generally intracellular and punctate. We speculate that the postnatal appearance of flow-dependent K secretion is determined by the transcriptional/translational regulation of expression of maxi-K channels. Furthermore, our studies suggest a novel function for intercalated cells in mediating flow-stimulated K secretion.
Fluid mechanics of eating, swallowing and digestion - overview and perspectives.
Engmann, Jan; Burbidge, Adam S
2013-02-26
From a very simplistic viewpoint, the human digestive system can be regarded as a long tube (with dramatic variations in diameter, cross-section, wall properties, pumping mechanisms, regulating valves and in-line sensors). We single out a few fluid mechanical phenomena along the trajectory of a food bolus from the mouth to the small intestine and discuss how they influence sensorial perception, safe transport, and nutrient absorption from a bolus. The focus is on lubrication flows between the tongue and palate, the oropharyngeal stage of swallowing and effects of flow on absorption in the small intestine. Specific challenges and opportunities in this research area are highlighted.
Modeling MHD Stagnation Point Flow of Thixotropic Fluid with Non-uniform Heat Absorption/Generation
NASA Astrophysics Data System (ADS)
Hayat, Tasawar; Shah, Faisal; Khan, Muhammad Ijaz; Alsaedi, Ahmed; Yasmeen, Tabassum
2017-12-01
Here magnetohydrodynamic (MHD) stagnation point flow by nonlinear stretching sheet is discussed. Variable thickness of sheet is accounted. In addition non-uniform heat generation/absorption concept is retained. Numerical treatment to arising nonlinear system is presented. Shooting procedure is adopted for numerical treatment. Graphs and tables lead to physical description of results. It is observed that skin friction enhances for ( H a) and it decays for different rising values of ( K 1), ( K 2) and ( n). Further temperature gradient increases for higher estimation of (Pr) and decreases for larger ( H a). Major findings of present analysis are presented.
NASA Astrophysics Data System (ADS)
Cui, Yehui; Zeng, Xiangguo; Kou, Huaqin; Ding, Jun; Wang, Fang
2018-06-01
In this work a three-dimensional (3D) hydrogen absorption model was proposed to study the heat transfer behavior in thin double-layered annular ZrCo beds. Numerical simulations were performed to investigate the effects of conversion layer thickness, thermal conductivity, cooling medium and its flow velocity on the efficiency of heat transfer. Results reveal that decreasing the layer thickness and improving the thermal conductivity enhance the ability of heat transfer. Compared with nitrogen and helium, water appears to be a better medium for cooling. In order to achieve the best efficiency of heat transfer, the flow velocity needs to be maximized.
Copper atom based measurements of velocity and turbulence in arc jet flows
NASA Technical Reports Server (NTRS)
Marinelli, William J.; Kessler, William J.; Allen, Mark G.; Arepalli, Sivaram; Scott, Carl D.
1991-01-01
Laboratory and field measurements were combined with a modeling effort to explore the feasibility of using atomic copper laser-induced fluorescence to measure velocity, turbulence, and temperature in arcjet flows. Both CW and pulsed frequency-doubled dye lasers were used to demonstrate the ability to measure velocity with 10 percent accuracy at rates of 200,000 cm/s in a rarefied flow of Cu atoms seeded in He. The pulsed laser established a threshold energy for power-broadening of the absorption line at 3.5 x 10 to the -8th J/sq cm. Field measurements at the NASA/JSC 10-MW arcjet facility demonstrated the ability to perform these measurements under actual test conditions. The use of this technique to measure freestream temperatures in the flow was examined for the 0.08/cm linewidth laser used in the NASA/JSC effort. Finally, single-shot turbulence measurements at the USAF/AEDC 35-MW H2 arcjet facility were measured with 4 percent accuracy using the laser/absorption line-overlap technique.
Hot planetary winds near a star: dynamics, wind-wind interactions, and observational signatures
NASA Astrophysics Data System (ADS)
Carroll-Nellenback, Jonathan; Frank, Adam; Liu, Baowei; Quillen, Alice C.; Blackman, Eric G.; Dobbs-Dixon, Ian
2017-04-01
Signatures of 'evaporative' winds from exoplanets on short (hot) orbits around their host star have been observed in a number of systems. In this paper, we present global adaptive mesh refinement simulations that track the launching of the winds, their expansion through the circumstellar environment, and their interaction with a stellar wind. We focus on purely hydrodynamic flows including the anisotropy of the wind launching and explore the orbital/fluid dynamics of the resulting flows in detail. In particular, we find that a combination of the tidal and Coriolis forces strongly distorts the planetary 'Parker' wind creating 'up-orbit' and 'down-orbit' streams. We characterize the flows in terms of their orbital elements that change depending on their launch position on the planet. We find that the anisotropy in the atmospheric temperature leads to significant backflow on to the planet. The planetary wind interacts strongly with the stellar wind creating instabilities that may cause eventual deposition of planetary gas on to the star. We present synthetic observations of both transit and absorption line-structure for our simulations. For our initial conditions, we find that the orbiting wind material produces absorption signatures at significant distances from the planet and substantial orbit-to-orbit variability. Lyα absorption shows red- and blueshifted features out to 70 km s-1. Finally, using semi-analytic models we constrain the effect of radiation pressure, given the approximation of uniform stellar absorption.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kendall, P.W.
The El Toro Library is a one-story facility that contains 10,000 square feet of floor area. The solar energy system was designed to provide 97% of the space heating load and 60% of the space cooling load. The solar energy system incorporates 82 panels with a gross area of 1427 square feet of evacuated tubular glass collectors (TC-100) manufactured by General Electric. The storage tank is a 1500-gallon insulated steel tank which is located outside, above ground level. The space heating subsystem uses solar energy from storage and/or thermal energy from the natural-gas-fired boiler. The space cooling subsystem uses anmore » absorption chiller to provide chilled water to the air-handling unit. As compared to the previous year, performance over the nine-month monitoring period was improved, based on overall solar contribution to the load. When compared to design values, the overall performance was poor. Overall solar fraction was an estimated 22% of the 220 million Btu system load. A total of 122 million Btu of solar energy was used by the space conditioning system. Auxiliary fossil fuel consumption was 608 million Btu, or 595,800 cubic feet of natural gas. Auxiliary thermal energy was a measured 68% of the auxiliary fossil fuel consumed. The solar savings ratio, a measure of the solar contribution to the load discounted by solar operating energy, averaged 19% during the analysis period. The previous year, the solar savings ratio was 16%.« less
Kim, Dongsu; Cox, Sam J.; Cho, Heejin; ...
2017-05-22
Variable refrigerant flow (VRF) systems are known for their high energy performance and thus can improve energy efficiency both in residential and commercial buildings. The energy savings potential of this system has been demonstrated in several studies by comparing the system performance with conventional HVAC systems such as rooftop variable air volume systems (RTU-VAV) and central chiller and boiler systems. This paper evaluates the performance of VRF and RTU-VAV systems in a simulation environment using widely-accepted whole building energy modeling software, EnergyPlus. A medium office prototype building model, developed by the U.S. Department of Energy (DOE), is used to assessmore » the performance of VRF and RTU-VAV systems. Each system is placed in 16 different locations, representing all U.S. climate zones, to evaluate the performance variations. Both models are compliant with the minimum energy code requirements prescribed in ASHRAE standard 90.1-2010 — energy standard for buildings except low-rise residential buildings. Finally, a comparison study between the simulation results of VRF and RTU-VAV models is made to demonstrate energy savings potential of VRF systems. The simulation results show that the VRF systems would save around 15–42% and 18–33% for HVAC site and source energy uses compared to the RTU-VAV systems. In addition, calculated results for annual HVAC cost savings point out that hot and mild climates show higher percentage cost savings for the VRF systems than cold climates mainly due to the differences in electricity and gas use for heating sources.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Dongsu; Cox, Sam J.; Cho, Heejin
Variable refrigerant flow (VRF) systems are known for their high energy performance and thus can improve energy efficiency both in residential and commercial buildings. The energy savings potential of this system has been demonstrated in several studies by comparing the system performance with conventional HVAC systems such as rooftop variable air volume systems (RTU-VAV) and central chiller and boiler systems. This paper evaluates the performance of VRF and RTU-VAV systems in a simulation environment using widely-accepted whole building energy modeling software, EnergyPlus. A medium office prototype building model, developed by the U.S. Department of Energy (DOE), is used to assessmore » the performance of VRF and RTU-VAV systems. Each system is placed in 16 different locations, representing all U.S. climate zones, to evaluate the performance variations. Both models are compliant with the minimum energy code requirements prescribed in ASHRAE standard 90.1-2010 — energy standard for buildings except low-rise residential buildings. Finally, a comparison study between the simulation results of VRF and RTU-VAV models is made to demonstrate energy savings potential of VRF systems. The simulation results show that the VRF systems would save around 15–42% and 18–33% for HVAC site and source energy uses compared to the RTU-VAV systems. In addition, calculated results for annual HVAC cost savings point out that hot and mild climates show higher percentage cost savings for the VRF systems than cold climates mainly due to the differences in electricity and gas use for heating sources.« less
Code of Federal Regulations, 2013 CFR
2013-07-01
... section (test substance), it is important to determine the rate of absorption of the test substance in... Sciences. 75:1094-1097. 1986. (ii) Bronaugh, R.L. and Stewart, R.F. Methods for In Vitro Percutaneous Absorption Studies IV: The Flow-Through Diffusion Cell. Journal of Pharmaceutical Sciences. 74:64-67. 1985...
Code of Federal Regulations, 2014 CFR
2014-07-01
... section (test substance), it is important to determine the rate of absorption of the test substance in... Sciences. 75:1094-1097. 1986. (ii) Bronaugh, R.L. and Stewart, R.F. Methods for In Vitro Percutaneous Absorption Studies IV: The Flow-Through Diffusion Cell. Journal of Pharmaceutical Sciences. 74:64-67. 1985...
Code of Federal Regulations, 2011 CFR
2011-07-01
... section (test substance), it is important to determine the rate of absorption of the test substance in... Sciences. 75:1094-1097. 1986. (ii) Bronaugh, R.L. and Stewart, R.F. Methods for In Vitro Percutaneous Absorption Studies IV: The Flow-Through Diffusion Cell. Journal of Pharmaceutical Sciences. 74:64-67. 1985...
Code of Federal Regulations, 2012 CFR
2012-07-01
... section (test substance), it is important to determine the rate of absorption of the test substance in... Sciences. 75:1094-1097. 1986. (ii) Bronaugh, R.L. and Stewart, R.F. Methods for In Vitro Percutaneous Absorption Studies IV: The Flow-Through Diffusion Cell. Journal of Pharmaceutical Sciences. 74:64-67. 1985...
USDA-ARS?s Scientific Manuscript database
Ergot alkaloids in endophyte-infected (Neotyphodium coenophialum) tall fescue (Lolium arundinaceum) have been shown to cause a reduction in blood flow to the rumen epithelium as well as a decrease in VFA absorption from the washed rumen of steers. Previous data also indicates that incubating an extr...
ERIC Educational Resources Information Center
Andersen, Jim
2012-01-01
Purpose: In order to understand the pros and cons of an open organization regarding the flow of knowledge between firms, this paper introduces the concept of "protective capacity". The purpose of the paper is to elaborate the concept of "protective capacity" especially in relation to absorptive capacity, by presenting a number of propositions.…
NASA Technical Reports Server (NTRS)
Lempert, Walter R.
1988-01-01
A simple technique for simultaneous determination of temperature and OH number density is described, along with characteristic results obtained from measurements using a premixed, hydrogen air flat flame burner. The instrumentation is based upon absorption of resonant radiation from a flowing microwave discharge lamp, and is rugged, relatively inexpensive, and very simple to operate.
Aguilar-Tapia, Antonio; Ould-Chikh, Samy; Lahera, Eric; Prat, Alain; Delnet, William; Proux, Olivier; Kieffer, Isabelle; Basset, Jean-Marie; Takanabe, Kazuhiro; Hazemann, Jean-Louis
2018-03-01
The construction of a high-temperature reaction cell for operando X-ray absorption spectroscopy characterization is reported. A dedicated cell was designed to operate as a plug-flow reactor using powder samples requiring gas flow and thermal treatment at high temperatures. The cell was successfully used in the reaction of dry reforming of methane (DRM). We present X-ray absorption results in the fluorescence detection mode on a 0.4 wt. % Ni/ZrO 2 catalyst under realistic conditions at 750 °C, reproducing the conditions used for a conventional dynamic microreactor for the DRM reaction. The setup includes a gas distribution system that can be fully remotely operated. The reaction cell offers the possibility of transmission and fluorescence detection modes. The complete setup dedicated to the study of catalysts is permanently installed on the Collaborating Research Groups French Absorption spectroscopy beamline in Material and Environmental sciences (CRG-FAME) and French Absorption spectroscopy beamline in Material and Environmental sciences at Ultra-High Dilution (FAME-UHD) beamlines (BM30B and BM16) at the European Synchrotron Radiation Facility in Grenoble, France.
NASA Astrophysics Data System (ADS)
Aguilar-Tapia, Antonio; Ould-Chikh, Samy; Lahera, Eric; Prat, Alain; Delnet, William; Proux, Olivier; Kieffer, Isabelle; Basset, Jean-Marie; Takanabe, Kazuhiro; Hazemann, Jean-Louis
2018-03-01
The construction of a high-temperature reaction cell for operando X-ray absorption spectroscopy characterization is reported. A dedicated cell was designed to operate as a plug-flow reactor using powder samples requiring gas flow and thermal treatment at high temperatures. The cell was successfully used in the reaction of dry reforming of methane (DRM). We present X-ray absorption results in the fluorescence detection mode on a 0.4 wt. % Ni/ZrO2 catalyst under realistic conditions at 750 °C, reproducing the conditions used for a conventional dynamic microreactor for the DRM reaction. The setup includes a gas distribution system that can be fully remotely operated. The reaction cell offers the possibility of transmission and fluorescence detection modes. The complete setup dedicated to the study of catalysts is permanently installed on the Collaborating Research Groups French Absorption spectroscopy beamline in Material and Environmental sciences (CRG-FAME) and French Absorption spectroscopy beamline in Material and Environmental sciences at Ultra-High Dilution (FAME-UHD) beamlines (BM30B and BM16) at the European Synchrotron Radiation Facility in Grenoble, France.
Chemically reactive species in squeezed flow through modified Fourier's and Fick's laws
NASA Astrophysics Data System (ADS)
Farooq, M.; Ahmad, S.; Javed, M.; Anjum, Aisha
2018-02-01
The squeezing flow of a Newtonian fluid with variable viscosity over a stretchable sheet embedded in Darcy porous medium is addressed. Cattaneo-Christov double diffusion models are adopted to disclose the salient features of heat and mass transport via variable thermal conductivity and variable mass diffusivity instead of conventional Fourier's and Fick's laws. Further, the concept of heat generation/absorption coefficient and first-order chemical reaction are also imposed to illustrate the characteristics of heat and mass transfer. Highly nonlinear computations are developed in dimensionless form and analyzed via the homotopic technique. The variation of flow parameters on velocity, concentration, and temperature distributions are sketched and disclosed physically. The results found that both concentration and temperature distributions decay for higher solutal and thermal relaxation parameters, respectively. Moreover, a higher chemical reaction parameter results in the reduction of the concentration field whereas the temperature profile enhances for a higher heat generation/absorption parameter.
Analysis of internal flow characteristics of a smooth-disk water-brake dynamometer
NASA Technical Reports Server (NTRS)
Evans, D. G.
1973-01-01
The principal of absorbing power with an enclosed partially submerged rotating disk through the turbulent viscous shearing of water is discussed. Reference information is used to develop a flow model of the water brake. A method is then presented that uses vector diagrams to relate the effects of rotational flow, through flow, and secondary flow to power absorption. The method is used to describe the operating characteristics of an example 111-cm (43.7-in.) diameter water brake. Correlating performance parameters are developed in a dimensional analysis.
[Purification of complicated industrial organic waste gas by complex absorption].
Chen, Ding-Sheng; Cen, Chao-Ping; Tang, Zhi-Xiong; Fang, Ping; Chen, Zhi-Hang
2011-12-01
Complicated industrial organic waste gas with the characteristics of low concentration,high wind volume containing inorganic dust and oil was employed the research object by complex absorption. Complex absorption mechanism, process flow, purification equipment and engineering application were studied. Three different surfactants were prepared for the composite absorbent to purify exhaust gas loaded with toluene and butyl acetate, respectively. Results show that the low surface tension of the composite absorbent can improve the removal efficiency of toluene and butyl acetate. With the advantages of the water film, swirl plate and fill absorption device, efficient absorption equipment was developed for the treatment of complicated industrial organic waste gas. It is with superiorities of simple structure, small size, anti-jam and high mass transfer. Based on absorption technology, waste gas treatment process integrated with heating stripping, burning and anaerobic and other processes, so that emissions of waste gas and absorption solution could meet the discharge standards. The technology has been put into practice, such as manufacturing and spraying enterprises.
Free-stream temperature, density, and pressure measurements in an expansion tube flow
NASA Technical Reports Server (NTRS)
Haggard, K. V.
1973-01-01
An experimental study was conducted to determine test-flow conditions in the Langley pilot model expansion tube. Measurements of temperature, density, wall pressure, pitot pressure, and shock and interface velocities were compared with theoretical calculations based on various models of the flow cycle. The vibrational temperature and integrated density of the molecular oxygen component of the flow were measured by use of vacuum ultraviolet absorption techniques. These measurements indicate both the presence and possible degree of nonequilibrium in the flow. Data are compared with several simplified models of the flow cycle, and data trends are discussed.
Zenebon, Odair; Sakuma, Alice M; Dovidauskas, Sergio; Okada, Isaura A; de, MaioFrancaD; Lichtig, Jaim
2002-01-01
A mixture of 50% H2O2-H2SO4 (3 + 1, v/v) was used for decomposition of food in open vessels at 80 degrees C. The treatment allowed rapid total mercury determination by flow injection cold vapor atomic absorption spectrometry. Cabbage, potatoes, peanuts paste, hazelnuts paste, oats, tomatoes and their derivatives, oysters, shrimps, prawns, shellfish, marine algae, and many kinds of fish were analyzed by the proposed methodology with a limit of quantitation of 0.86 +/- 0.08 microg/L mercury in the final solution. Reference materials tested also gave excellent recovery.
Wide-field absolute transverse blood flow velocity mapping in vessel centerline
NASA Astrophysics Data System (ADS)
Wu, Nanshou; Wang, Lei; Zhu, Bifeng; Guan, Caizhong; Wang, Mingyi; Han, Dingan; Tan, Haishu; Zeng, Yaguang
2018-02-01
We propose a wide-field absolute transverse blood flow velocity measurement method in vessel centerline based on absorption intensity fluctuation modulation effect. The difference between the light absorption capacities of red blood cells and background tissue under low-coherence illumination is utilized to realize the instantaneous and average wide-field optical angiography images. The absolute fuzzy connection algorithm is used for vessel centerline extraction from the average wide-field optical angiography. The absolute transverse velocity in the vessel centerline is then measured by a cross-correlation analysis according to instantaneous modulation depth signal. The proposed method promises to contribute to the treatment of diseases, such as those related to anemia or thrombosis.
Applicability of steady models for hot-star winds
NASA Technical Reports Server (NTRS)
Owocki, Stanley P.; Poe, Clint H.; Castor, John I.
1990-01-01
Non-Sobolev models of radiatively driven stellar winds based on a pure-absorption approximation do not have a well-defined steady state. Here the implications of this for flow time-dependence are examined, showing that, under such circumstances, instabilities in the flow attain an absolute character that leads to intrinsic variability. In this case, steady solutions are inherently inapplicable because they do not represent physically realizable states. However, for actual hot-star winds, driving is principally by scattering, not pure absorption. In practice, the relatively weak force associated with slight asymmetries in the diffuse, scattered radiation field may play a crucial role in breaking the solution degeneracy and reducing the instability from an absolute to an advective character.
NASA Astrophysics Data System (ADS)
Wei, Chuyu; Pineda, Daniel I.; Paxton, Laurel; Egolfopoulos, Fokion N.; Spearrin, R. Mitchell
2018-06-01
A tomographic laser absorption spectroscopy technique, utilizing mid-infrared light sources, is presented as a quantitative method to spatially resolve species and temperature profiles in small-diameter reacting flows relevant to combustion systems. Here, tunable quantum and interband cascade lasers are used to spectrally resolve select rovibrational transitions near 4.98 and 4.19 μm to measure CO and {CO2}, respectively, as well as their vibrational temperatures, in piloted premixed jet flames. Signal processing methods are detailed for the reconstruction of axial and radial profiles of thermochemical structure in a canonical ethylene-air jet flame. The method is further demonstrated to quantitatively distinguish between different turbulent flow conditions.
Sources and potential application of waste heat utilization at a gas processing facility
NASA Astrophysics Data System (ADS)
Alshehhi, Alyas Ali
Waste heat recovery (WHR) has the potential to significantly improve the efficiency of oil and gas plants, chemical and other processing facilities, and reduce their environmental impact. In this Thesis a comprehensive energy audit at Abu Dhabi Gas Industries Ltd. (GASCO) ASAB gas processing facilities is undertaken to identify sources of waste heat and evaluate their potential for on-site recovery. Two plants are considered, namely ASAB0 and ASAB1. Waste heat evaluation criteria include waste heat grade (i.e., temperature), rate, accessibility (i.e., proximity) to potential on-site waste heat recovery applications, and potential impact of recovery on installation performance and safety. The operating parameters of key waste heat source producing equipment are compiled, as well as characteristics of the waste heat streams. In addition, potential waste heat recovery applications and strategies are proposed, focusing on utilities, i.e., enhancement of process cooling/heating, electrical/mechanical power generation, and steam production. The sources of waste heat identified at ASAB facilities consist of gas turbine and gas generator exhaust gases, flared gases, excess propane cooling capacity, excess process steam, process gas air-cooler heat dissipation, furnace exhaust gases and steam turbine outlet steam. Of the above waste heat sources, exhaust gases from five gas turbines and one gas generator at ASAB0 plant, as well as from four gas turbines at ASAB1 plant, were found to meet the rate (i.e., > 1 MW), grade (i.e., > 180°C), accessibility (i.e., < 50 m from potential on-site WHR applications) and minimal impact criteria on the performance and safety of existing installations, for potential waste heat recovery. The total amount of waste heat meeting these criteria were estimated at 256 MW and 289 MW at ASAB0 and ASAB1 plants, respectively, both of which are substantial. Of the 289 MW waste generated at ASAB1, approximately 173 MW are recovered by waste heat recovery steam generators (WHRSGs), leaving 116 MW unutilized. The following strategies were developed to recover the above waste heat. At ASAB0, it is proposed that exhaust gases from all five gas turbines be used to power a WHRSG. The steam generated by the WHRSG would both i) drive an absorption refrigeration unit for gas turbine inlet air cooling, which would result in additional electric or mechanical power generation, and pre-cooling of process gas, which could reduce the need for or eliminate air coolers, as well as reduce propane chiller load, and ii) serve for heating of lean gas, which would reduce furnace load. At ASAB1, it is proposed that exhaust gases from all four gas turbines be used to generate steam in WHRSG that would drive an absorption refrigeration unit for either gas turbine inlet air cooling for additional electric or mechanical power generation, or pre-cooling of process gas to eliminate air-coolers and reduce propane chiller cooling load. Considering the smaller amount of waste heat available at ASAB1 (116 MW) relative to ASAB0 (237 MW), these above two recovery options could not be implemented simultaneously at ASAB0. To permit the detailed design and techno-economic feasibility evaluation of the proposed waste heat recovery strategies in a subsequent study, the cooling loads and associated electric power consumption of ASAB0 process gas air-coolers were estimated at 21 MW and 1.9 MW, respectively, and 67 MW and 2.2 MW, respectively for ASAB1 plant. In addition, the heating loads and fuel consumption of ASAB0 furnaces used for lean gas re-generation were estimated at 24 MW and 0.0653 MMSCMD, respectively. In modeling work undertaken in parallel with this study at the Petroleum Institute, the waste heat recovery strategies proposed here were found to be thermodynamically and economically feasible, and to lead to substantial energy and cost savings, hence environmental benefits.
Analyzing and Post-modelling the High Speed Images of a Wavy Laser Induced Boiling Front
NASA Astrophysics Data System (ADS)
Matti, R. S.; Kaplan, A. F. H.
The boiling front in laser materials processing like remote fusion cutting, keyhole welding or drilling can nowadays be recorded by high speed imaging. It was recently observed that bright waves flow down the front. Several complex physical mechanisms are associated with a stable laser-induced boiling front, like beam absorption, shadowing, heating, ablation pressure, fluid flow, etc. The evidence of dynamic phenomena from high speed imaging is closely linked to these phenomena. As a first step, the directly visible phenomena were classified and analyzed. This has led to the insight that the appearance of steady flow of the bright front peaks is a composition of many short flashing events of 20-50 μs duration, though composing a rather constant melt film flow downwards. Five geometrical front shapes of bright and dark domains were categorized, for example long inclined dark valleys. In addition, the special top and bottom regions of the front are distinguished. As a second step, a new method of post-modelling based on the greyscale variation of the images was applied, to approximately reconstruct the topology of the wavy front and subsequently to calculate the absorption across the front. Despite certain simplifications this kind of analysis provides a variety of additional information, including statistical analysis. In particular, the model could show the sensitivity of front waves to the formation of shadow domains and the robustness of fiber lasers to keep most of an irradiated steel surface in an absorptivity window between 35 to 43%.
Physical conditions in broad and associated narrow absorption-line systems toward APM 08279+5255
NASA Astrophysics Data System (ADS)
Srianand, R.; Petitjean, P.
2000-05-01
Results of a careful analysis of the absorption systems with z_abs =~ z_em seen toward the bright, z_em ~ 3.91, gravitationally lensed quasar APM 08279+5255 are presented. Two of the narrow-line systems, at z_abs = 3.8931 and z_abs = 3.9135, show absorptions from singly ionized species with weak or no N v and O vi absorptions at the same redshift. Absorption due to fine structure transitions of C ii and S ii i (excitation energies corresponding to, respectively, 156mu m and 34mu m) are detected at z_abs = 3.8931. Excitation by IR radiation is favored as the column density ratios are consistent with the shape of APM 08279+5255 IR spectrum. The low-ionization state of the system favors a picture where the cloud is closer to the IR source than to the UV source, supporting the idea that the extension of the IR source is larger than ~ 200 pc. The absence of fine structure lines at z_abs = 3.9135 suggests that the gas responsible for this system is farther away from the IR source. Abundances are ~ 0.01 and 1 Zsun at z_abs = 3.913 and 3.8931 and aluminum could be over-abundant with respect to silicon and carbon by at least a factor of two and five. All this suggests that whereas the z_abs = 3.8931 system is probably located within 200 pc from the QSO and ejected at a velocity larger than 1000 km s-1, the z_abs = 3.9135 system is farther away and part of the host-galaxy. Several narrow-line systems have strong absorption lines due to C iv, O vi and N v and very low neutral hydrogen optical depths. This probably implies metallicities Z>= Z_sun although firm conclusion cannot be drawn as the exact value depends strongly on the shape of the ionizing spectrum. The C iv broad absorption has a complex structure with mini-BALs (width <= 1000 km s-1) and narrow components superposed on a continuous absorption of smaller optical depth. The continuous absorption is much stronger in O vi indicating that the corresponding gas-component is of higher ionization than the other components in the flow and that absorption structures in the BAL-flow are mainly due to density inhomogeneities. There is a tendency for mini-BALs to have different covering factors for different species. It is shown that a few of the absorbing clouds do not cover all the three QSO images, especially we conclude that the z_abs = 3.712 system covers only image C. Finally we identify narrow components within the BAL-flow with velocity separations within 5 km s-1 of the O vi, N v and S ii v doublet splittings suggesting that line driven radiative acceleration is an important process to explain the out-flow. Based on observations collected at the W.M. Keck Observatory, which is operated as a scientific partnership among the California Institute of Technology, the University of California and the National Aeronautics and Space Administration. The Observatory was made possible by the generous financial support of the W.M. Keck Foundation.
Predictive Optimal Control of Active and Passive Building Thermal Storage Inventory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gregor P. Henze; Moncef Krarti
2005-09-30
Cooling of commercial buildings contributes significantly to the peak demand placed on an electrical utility grid. Time-of-use electricity rates encourage shifting of electrical loads to off-peak periods at night and weekends. Buildings can respond to these pricing signals by shifting cooling-related thermal loads either by precooling the building's massive structure or the use of active thermal energy storage systems such as ice storage. While these two thermal batteries have been engaged separately in the past, this project investigated the merits of harnessing both storage media concurrently in the context of predictive optimal control. To pursue the analysis, modeling, and simulationmore » research of Phase 1, two separate simulation environments were developed. Based on the new dynamic building simulation program EnergyPlus, a utility rate module, two thermal energy storage models were added. Also, a sequential optimization approach to the cost minimization problem using direct search, gradient-based, and dynamic programming methods was incorporated. The objective function was the total utility bill including the cost of reheat and a time-of-use electricity rate either with or without demand charges. An alternative simulation environment based on TRNSYS and Matlab was developed to allow for comparison and cross-validation with EnergyPlus. The initial evaluation of the theoretical potential of the combined optimal control assumed perfect weather prediction and match between the building model and the actual building counterpart. The analysis showed that the combined utilization leads to cost savings that is significantly greater than either storage but less than the sum of the individual savings. The findings reveal that the cooling-related on-peak electrical demand of commercial buildings can be considerably reduced. A subsequent analysis of the impact of forecasting uncertainty in the required short-term weather forecasts determined that it takes only very simple short-term prediction models to realize almost all of the theoretical potential of this control strategy. Further work evaluated the impact of modeling accuracy on the model-based closed-loop predictive optimal controller to minimize utility cost. The following guidelines have been derived: For an internal heat gain dominated commercial building, reasonable geometry simplifications are acceptable without a loss of cost savings potential. In fact, zoning simplification may improve optimizer performance and save computation time. The mass of the internal structure did not show a strong effect on the optimization. Building construction characteristics were found to impact building passive thermal storage capacity. It is thus advisable to make sure the construction material is well modeled. Zone temperature setpoint profiles and TES performance are strongly affected by mismatches in internal heat gains, especially when they are underestimated. Since they are a key factor in determining the building cooling load, efforts should be made to keep the internal gain mismatch as small as possible. Efficiencies of the building energy systems affect both zone temperature setpoints and active TES operation because of the coupling of the base chiller for building precooling and the icemaking TES chiller. Relative efficiencies of the base and TES chillers will determine the balance of operation of the two chillers. The impact of mismatch in this category may be significant. Next, a parametric analysis was conducted to assess the effects of building mass, utility rate, building location and season, thermal comfort, central plant capacities, and an economizer on the cost saving performance of optimal control for active and passive building thermal storage inventory. The key findings are: (1) Heavy-mass buildings, strong-incentive time-of-use electrical utility rates, and large on-peak cooling loads will likely lead to attractive savings resulting from optimal combined thermal storage control. (2) By using economizer to take advantage of the cool fresh air during the night, the building electrical cost can be reduced by using less mechanical cooling. (3) Larger base chiller and active thermal storage capacities have the potential of shifting more cooling loads to off-peak hours and thus higher savings can be achieved. (4) Optimal combined thermal storage control with a thermal comfort penalty included in the objective function can improve the thermal comfort levels of building occupants when compared to the non-optimized base case. Lab testing conducted in the Larson HVAC Laboratory during Phase 2 showed that the EnergyPlus-based simulation was a surprisingly accurate prediction of the experiment. Therefore, actual savings of building energy costs can be expected by applying optimal controls from simulation results.« less
The imaging and modelling of the physical processes involved in digestion and absorption.
Schulze, K S
2015-02-01
The mechanical activity of the gastro-intestinal tract serves to store, propel and digest food. Contractions disperse particles and transform solids and secretions into the two-phase slurry called chyme; movements of the intestine deliver nutrients to mucosal sites of absorption, and from the submucosa into the lymphatic and portal venous circulation. Colonic motor activity helps to extract fluid and electrolytes from chyme and to compound and compact luminal debris into faeces for elimination. We outline how dynamic imaging by ultrasound and magnetic resonance can demonstrate intestinal flow processes critical to digestion like mixing, dilution, swelling, dispersion and elution. Computational fluid mechanics enables a numerical rendition of the forces promoting digestion: pressure and flow fields, the shear stresses dispersing particles or the effectiveness of bolus mixing can be calculated. These technologies provide new insights into the mechanical processes that promote digestion and absorption. © 2014 This article is a U.S. Government work and is in the public domain in the USA.
Pan, Wenxiao; Galvin, Janine; Huang, Wei Ling; ...
2018-03-25
In this paper we aim to develop a validated device-scale CFD model that can predict quantitatively both hydrodynamics and CO 2 capture efficiency for an amine-based solvent absorber column with random Pall ring packing. A Eulerian porous-media approach and a two-fluid model were employed, in which the momentum and mass transfer equations were closed by literature-based empirical closure models. We proposed a hierarchical approach for calibrating the parameters in the closure models to make them accurate for the packed column. Specifically, a parameter for momentum transfer in the closure was first calibrated based on data from a single experiment. Withmore » this calibrated parameter, a parameter in the closure for mass transfer was next calibrated under a single operating condition. Last, the closure of the wetting area was calibrated for each gas velocity at three different liquid flow rates. For each calibration, cross validations were pursued using the experimental data under operating conditions different from those used for calibrations. This hierarchical approach can be generally applied to develop validated device-scale CFD models for different absorption columns.« less
Temperature dependence of the NO3 absorption spectrum
NASA Technical Reports Server (NTRS)
Sander, Stanley P.
1986-01-01
The absorption spectrum of the gas-phase NO3 radical has been studied between 220 and 700 nm by using both flash photolysis and discharge flow reactors for the production of NO3. In the flash photolysis method, cross sections at the peak of the (0,0) band at 661.9 nm were measured relative to the cross section of ClONO2 at several different wavelengths. From the best current measurements of the ClONO2 spectrum, the NO3 cross section at 661.9 nm was determined to be (2.28 + or 0.34) x 10 to the -17th sq cm/molecule at 298 K. Measurements at 230 K indicated that the cross section increases by a factor of 1.18 at the peak of the (0,0) band. The discharge flow method was used both to obtain absolute cross sections at 661.9 nm and to obtain relative absorption spectra between 300 and 700 nm at 298 and 230 K. A value of (1.83 + or - 0.27) x 10 to the -17th sq cm/molecule was obtained for sigma NO3 at 661.9 nm at 298 K. Upper limits to the NO3 cross sections were also measured between 220 and 260 nm with the discharge flow method.
Xie, Xiaofeng; Tolley, Luke T; Truong, Thy X; Tolley, H Dennis; Farnsworth, Paul B; Lee, Milton L
2017-11-10
The design of a miniaturized LED-based UV-absorption detector was significantly improved for on-column nanoflow LC. The detector measures approximately 27mm×24mm×10mm and weighs only 30g. Detection limits down to the nanomolar range and linearity across 3 orders of magnitude were obtained using sodium anthraquinone-2-sulfonate as a test analyte. Using two miniaturized detectors, a dual-detector system was assembled containing 255nm and 275nm LEDs with only 216nL volume between the detectors A 100μm slit was used for on-column detection with a 150μm i.d. packed capillary column. Chromatographic separation of a phenol mixture was demonstrated using the dual-detector system, with each detector producing a unique chromatogram. Less than 6% variation in the ratios of absorbances measured at the two wavelengths for specific analytes was obtained across 3 orders of magnitude concentration, which demonstrates the potential of using absorption ratio measurements for target analyte detection. The dual-detector system was used for simple, but accurate, mobile phase flow rate measurement at the exit of the column. With a flow rate range from 200 to 2000nL/min, less than 3% variation was observed. Copyright © 2017 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pan, Wenxiao; Galvin, Janine; Huang, Wei Ling
In this paper we aim to develop a validated device-scale CFD model that can predict quantitatively both hydrodynamics and CO 2 capture efficiency for an amine-based solvent absorber column with random Pall ring packing. A Eulerian porous-media approach and a two-fluid model were employed, in which the momentum and mass transfer equations were closed by literature-based empirical closure models. We proposed a hierarchical approach for calibrating the parameters in the closure models to make them accurate for the packed column. Specifically, a parameter for momentum transfer in the closure was first calibrated based on data from a single experiment. Withmore » this calibrated parameter, a parameter in the closure for mass transfer was next calibrated under a single operating condition. Last, the closure of the wetting area was calibrated for each gas velocity at three different liquid flow rates. For each calibration, cross validations were pursued using the experimental data under operating conditions different from those used for calibrations. This hierarchical approach can be generally applied to develop validated device-scale CFD models for different absorption columns.« less
Device Scale Modeling of Solvent Absorption using MFIX-TFM
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carney, Janine E.; Finn, Justin R.
Recent climate change is largely attributed to greenhouse gases (e.g., carbon dioxide, methane) and fossil fuels account for a large majority of global CO 2 emissions. That said, fossil fuels will continue to play a significant role in the generation of power for the foreseeable future. The extent to which CO 2 is emitted needs to be reduced, however, carbon capture and sequestration are also necessary actions to tackle climate change. Different approaches exist for CO 2 capture including both post-combustion and pre-combustion technologies, oxy-fuel combustion and/or chemical looping combustion. The focus of this effort is on post-combustion solvent-absorption technology.more » To apply CO 2 technologies at commercial scale, the availability and maturity and the potential for scalability of that technology need to be considered. Solvent absorption is a proven technology but not at the scale needed by typical power plant. The scale up and down and design of laboratory and commercial packed bed reactors depends heavily on the specific knowledge of two-phase pressure drop, liquid holdup, the wetting efficiency and mass transfer efficiency as a function of operating conditions. Simple scaling rules often fail to provide proper design. Conventional reactor design modeling approaches will generally characterize complex non-ideal flow and mixing patterns using simplified and/or mechanistic flow assumptions. While there are varying levels of complexity used within these approaches, none of these models resolve the local velocity fields. Consequently, they are unable to account for important design factors such as flow maldistribution and channeling from a fundamental perspective. Ideally design would be aided by development of predictive models based on truer representation of the physical and chemical processes that occur at different scales. Computational fluid dynamic (CFD) models are based on multidimensional flow equations with first principle foundations. CFD models can include a more accurate physical description of flow processes and be modified to include more complex behavior. Wetting performance and spatial liquid distribution inside the absorber are recognized as weak areas of knowledge requiring further investigation. CFD tools offer a possible method to investigating such topics and gaining a better understanding of their influence on reactor performance. This report focuses first on describing a hydrodynamic model for countercurrent gas-liquid flow through a packed column and then on the chemistry, heat and mass transfer specific to CO 2 absorption using monoethanolamine (MEA). The indicated model is implemented in MFIX, a CFD open source software package. The user defined functions needed to build this model are described in detail along with the keywords for the corresponding input file. A test case is outlined along with a few results. The example serves to briefly illustrate the developed CFD tool and its potential capability to investigate solvent absorption.« less
USDA-ARS?s Scientific Manuscript database
Ergot alkaloids present in endophyte-infected tall fescue are the causative agents for fescue toxicosis in cattle. Ergot alkaloids have been shown to cause a reduction in blood flow to the rumen epithelium as well as a decrease in short-chain fatty acid (SCFA) absorption from the washed rumen of ste...
Description and status of NASA-LeRC/DOE photovoltaic applications systems
NASA Technical Reports Server (NTRS)
Ratajczak, A. F.
1978-01-01
Designed, fabricated and installed were 16 geographically dispersed photovoltaic systems. These systems are powering a refrigerator, highway warning sign, forest lookout towers, remote weather stations, a water chiller at a visitor center, and insect survey traps. Each of these systems is described in terms of load requirements, solar array and battery size, and instrumentation and controls. Operational experience is described and present status is given for each system. The P/V power systems have proven to be highly reliable with almost no problems with modules and very few problems overall.
Design of a Pilot Plant for Vacuum Infusion of High Lipoidal Liquids into Dried Foods
1988-07-01
on a conveyor belt equipped with a chiller hood. /". 20 DISTRIBUTION’AVAILABILITY OF ABSTRACT SUNCLASSlFlEn’VL’V’S:» Q jwj AS RB" U DtiC US...design is an optimization of design criteria, shown in Figure I. In addition to the basic design criteria, the equipment must operate within a...the desired setpoint . 2.2 Lipoidal Liquid Systems; The lipoidal liquid is provided at the proper conditions to the immersion dish from an
1980-08-01
orientation, and HVAC systems have on three Army buildings in five different climatic regions. f Optimization of EnerV Usage in Military Facilities...The clinic’s environment is maintained by a multizone air-handling unit served by its own boiler and chiller . The building was modeled with 30... setpoints for the space temperature. This type of throttling range allows the heating system to control around a throttling range of 67 to 69oF (19 to 200
2004-01-01
cooled below –40ºC with the ultra low temperature chiller operating at –50ºC. At these low temperatures, elastomer compounds (i.e. nylon hose and o...projector hardware. Consideration of steel braided Teflon hose or even a thin wall flexible steel hose will be made for future operation of the YUGO...Cajon VCR vacuum port on the bottom of the array using a metal gasket. This change eliminated one elastomer seal that was most likely to fail at low
1997-08-27
Larry Laseter (left), vice president of Sales and Marketing for the Florida Power & Light (FPL) Company, presents Kennedy Space Center (KSC) Director Roy Bridges Jr., with a rebate check for $195,000, recognizing KSC's commitment to reducing overall energy consumption and costs now and in the future. The energy savings realized by KSC come as a direct result of installing new chilled water systems hardware in the KSC Industrial Area Chiller Plant. KSC has received FPL rebates for its energy-saving efforts since 1993, but this check is the largest single-project rebate to date
Spectroscopy-based thrust sensor for high-speed gaseous flows
NASA Technical Reports Server (NTRS)
Hanson, Ronald K. (Inventor)
1993-01-01
A system and method for non-intrusively obtaining the thrust value of combustion by-products of a jet engine is disclosed herein. The system includes laser elements for inducing absorption for use in determining the axial velocity and density of the jet flow stream and elements for calculating the thrust value therefrom.
Ergot alkaloids decrease rumen epithelial blood flow
USDA-ARS?s Scientific Manuscript database
Two experiments were conducted to determine if ergot alkaloids affect blood flow to the absorptive surface of the rumen of steers. Steers (n=8 total) were pair-fed alfalfa cubes at 1.5× NEM and received ground endophyte-infected tall fescue seed (E+) or endophyte-free tall fescue seed (E-) via rumen...
Toledo-Cervantes, Alma; Madrid-Chirinos, Cindy; Cantera, Sara; Lebrero, Raquel; Muñoz, Raúl
2017-02-01
The potential of an algal-bacterial system consisting of a high rate algal pond (HRAP) interconnected to an absorption column (AC) via recirculation of the cultivation broth for the upgrading of biogas and digestate was investigated. The influence of the gas-liquid flow configuration in the AC on the photosynthetic biogas upgrading process was assessed. AC operation in a co-current configuration enabled to maintain a biomass productivity of 15gm -2 d -1 , while during counter-current operation biomass productivity decreased to 8.7±0.5gm -2 d -1 as a result of trace metal limitation. A bio-methane composition complying with most international regulatory limits for injection into natural gas grids was obtained regardless of the gas-liquid flow configuration. Furthermore, the influence of the recycling liquid to biogas flowrate (L/G) ratio on bio-methane quality was assessed under both operational configurations obtaining the best composition at an L/G ratio of 0.5 and co-current flow operation. Copyright © 2016 Elsevier Ltd. All rights reserved.
Domínguez, Marina A; Grünhut, Marcos; Pistonesi, Marcelo F; Di Nezio, María S; Centurión, María E
2012-05-16
An automatic flow-batch system that includes two borosilicate glass chambers to perform sample digestion and cold vapor atomic absorption spectroscopy determination of mercury in honey samples was designed. The sample digestion was performed by using a low-cost halogen lamp to obtain the optimum temperature. Optimization of the digestion procedure was done using a Box-Behnken experimental design. A linear response was observed from 2.30 to 11.20 μg Hg L(-1). The relative standard deviation was 3.20% (n = 11, 6.81 μg Hg L(-1)), the sample throughput was 4 sample h(-1), and the detection limit was 0.68 μg Hg L(-1). The obtained results with the flow-batch method are in good agreement with those obtained with the reference method. The flow-batch system is simple, allows the use of both chambers simultaneously, is seen as a promising methodology for achieving green chemistry goals, and is a good proposal to improving the quality control of honey.
Peng, Wen Yu; Goldenstein, Christopher S; Mitchell Spearrin, R; Jeffries, Jay B; Hanson, Ronald K
2016-11-20
The development and demonstration of a four-color single-ended mid-infrared tunable laser-absorption sensor for simultaneous measurements of H2O, CO2, CO, and temperature in combustion flows is described. This sensor operates by transmitting laser light through a single optical port and measuring the backscattered radiation from within the combustion device. Scanned-wavelength-modulation spectroscopy with second-harmonic detection and first-harmonic normalization (scanned-WMS-2f/1f) was used to account for variable signal collection and nonabsorption losses in the harsh environment. Two tunable diode lasers operating near 2551 and 2482 nm were utilized to measure H2O concentration and temperature, while an interband cascade laser near 4176 nm and a quantum cascade laser near 4865 nm were used for measuring CO2 and CO, respectively. The lasers were modulated at either 90 or 112 kHz and scanned across the peaks of their respective absorption features at 1 kHz, leading to a measurement rate of 2 kHz. A hybrid demultiplexing strategy involving both spectral filtering and frequency-domain demodulation was used to decouple the backscattered radiation into its constituent signals. Demonstration measurements were made in the exhaust of a laboratory-scale laminar methane-air flat-flame burner at atmospheric pressure and equivalence ratios ranging from 0.7 to 1.2. A stainless steel reflective plate was placed 0.78 cm away from the sensor head within the combustion exhaust, leading to a total absorption path length of 1.56 cm. Detection limits of 1.4% H2O, 0.6% CO2, and 0.4% CO by mole were reported. To the best of the authors' knowledge, this work represents the first demonstration of a mid-infrared laser-absorption sensor using a single-ended architecture in combustion flows.
Ellis, P R; Roberts, F G; Low, A G; Morgan, L M
1995-10-01
The present study was designed to determine the quantitative effects of starchy meals containing guar gum on rates of net apparent glucose absorption and net apparent insulin and gastric inhibitory polypeptide (GIP) production in growing pigs. The effects of these meals on the viscosity of jejunal digesta were also examined and correlated to changes in glucose absorption. Four growing pigs were each given either a low-fat semi-purified diet (control) or the same diet supplemented with a high-molecular-weight guar gum at concentrations in the diet of 20 or 40 g/kg. Blood samples were removed simultaneously via indwelling catheters from the mesenteric artery and the hepatic portal vein. Samples of jejunal digesta were removed via a T-piece cannula and used immediately for viscosity measurements at 39 degrees. The 'zero-shear' viscosity of each sample was then calculated. Blood-flow measurements were made using an ultrasonic flow probe fitted to the hepatic portal vein. All measurements were made at intervals of 10 or 30 min during a 4 h postprandial period. Meals containing guar gum significantly increased (P < 0.05) the viscosity of jejunal digesta, an effect that was strongly dependent on the concentration of guar gum in the original diet. No significant differences in blood-flow rates were found between the control and guar-containing diets. Both concentrations of guar gum significantly reduced (P < 0.05) glucose absorption and insulin and GIP secretion rates over the 4 h postprandial period. An inverse relationship between the rate of glucose absorption and the 'zero-shear' viscosity of jejunal digesta was found. This study also provides direct evidence for the important role played by the enteroinsular axis in modifying the glycaemic response to a meal containing guar gum.
NASA Astrophysics Data System (ADS)
Seeger, Tassia S.; Machado, Eduarda Q.; Flores, Erico M. M.; Mello, Paola A.; Duarte, Fabio A.
2018-03-01
In this study, Na and K were determined in desalted crude oil by direct sampling graphite furnace atomic absorption spectrometry (DS-GF AAS), with the use of a Zeeman-effect background correction system with variable magnetic field. The analysis was performed in low and high sensitivity conditions. Sodium determination was performed in two low-sensitivity conditions: 1) main absorption line (589.0 nm), gas stop flow during the atomization step and 3-field dynamic mode (0.6-0.8 T); and 2) secondary absorption line (330.3 nm), gas stop flow during the atomization and 2-field mode (0.8 T). In K determination, some parameters, such as high-sensitivity mode, main absorption line (766.5 nm), gas stop flow during the atomization and 2-field mode (0.8 T), were used. Suitability of chemical modifiers, such as Pd and W-Ir was also evaluated. The heating program for Na and K was based on the pyrolysis and atomization curves. Calibration was performed by aqueous standards. Accuracy was evaluated by the analysis of Green Petroleum Coke (SRM NIST 2718) and Trace Elements in Fuel Oil (SRM NIST 1634c). Recovery tests were also performed and results were compared with those obtained by GF AAS after crude oil digestion by microwave-assisted digestion. The characteristic mass of Na was 17.1 pg and 0.46 ng in conditions 1 and 2, respectively, while the one of K was 1.4 pg. Limits of detection and quantification by DS-GF AAS were 30 and 40 ng g-1 for Na and 3.2 and 4.2 ng g-1 for K, respectively. Sodium and K were determined in three crude oil samples with API density ranging from 20.9 to 28.0. Sodium and K concentration ranged from 1.5 to 73 μg g-1 and from 23 to 522 ng g-1, respectively.
NASA Astrophysics Data System (ADS)
Phillips, Grady T.
Optical techniques for measuring the temperature in three-dimensional supersonic reactive flows have typically depended on lineshape measurements using single-beam laser absorption spectroscopy. However, absorption over extended path lengths in flows with symmetric, turbulent eddies can lead to systematically high extracted temperatures due to Doppler shifts resulting from flow along the absorption path. To eliminate these problems and provide full three-dimensional spatial resolution, two variants of laser saturation spectroscopy have been developed and demonstrated, for the first time, which utilize two crossed and nearly copropogating laser beams. Individual rotational lines in the visible I2 X 1Sigma 0+g → B 3pi 0+u transition were used to develop the two diagnostic to support research on the Chemical Oxygen-Iodine Laser (COIL), the weapon aboard the USAF Airborne Laser. Cross-Beam Saturation Absorption Spectroscopy (CBSAS) and Cross-Beam Inter-Modulated Fluorescence (CBIMF) were demonstrated as viable methods for recording the spectral signal of an I2 ro-vibrational line in a small three-dimensional volume using a tunable CW dye laser. Temperature is extracted by fitting the recorded signal with a theoretical signal constructed from the Doppler-broadened hyperfine components of the ro-vibrational line. The CBIMF technique proved successful for extracting the temperature of an I2-seeded, Ar gas flow within a small, Mach 2, Laval nozzle where the overlap volume of the two 1 mm diameter laser beams was 2.4 mm 3. At a test point downstream of the nozzle throat, the average temperature of 146 K +/- 1.5 K extracted from measurements of the I2 P(46) 17-1 spectral line compared favorably with the 138 K temperature calculated from isentropic, one-dimensional flow theory. CBIMF provides sufficient accuracy for characterizing the temperature of the gas flow in a COIL device, and could be applied to other areas of flow-field characterization and nozzle design. In contrast, the CBSAS signal was not sufficiently strong for reliable temperature extraction from the 2.4 mm3 overlap volume required in the nozzle experiments. Otherwise, the CBSAS technique could have greater success for application in flow field test environments that allow the use of a larger overlap-volume. CBIMF and CBSAS measurements were also made in a static cell at 293 K. At 50 mTorr of I2, the standard error in temperature from CBIMF measurements of the I2 P(46) 17-1 line was approximately 0.5 K. For CBSAS, the standard error in temperature was approximately 3 K at 50 mTorr of I2. Accuracy improved with increasing I2 pressure. In addition, the spatial-resolution capability of CBIMF and CBSAS was demonstrated in a static cell with an applied temperature gradient ranging from 300 to 365 K. Extracted temperatures were compared to thermocouple measurements at multiple positions in the gradient. Agreement between extracted temperatures and thermocouple measurements was better at the lower temperatures. Doppler-free measurements of several I2 hyperfine spectra were also performed to support development of the theoretical model. Saturation Absorption Spectroscopy was used to obtain Ar pressure broadening rates of 8.29 +/- 0.30 MHz/Torr for the I2 P(70) 17-1 hyperfine spectrum, and 10.70 +/- 0.41 MHz/Torr for the I2 P(10) 17-1 hyperfine spectrum.
Absorption characteristics of glass fiber materials at normal and oblique incidence. M.S. Thesis
NASA Technical Reports Server (NTRS)
Wyerman, B. R.
1974-01-01
The absorption characteristics of several fibrous materials of the Owens Corning 700 Fiberglas Series were measured to determine the variation in impedance as a function of incident angle of the sound wave. The results, indicate that the fibrous absorbents behave as extended reacting materials. The poor agreement between measurement and theory for sound absorption based on the parameters of flow resistance and porosity indicates that this theory does not adequately predict the acoustic behavior of fibrous materials. A much better agreement with measured results is obtained for values calculated from the bulk acoustic parameters of the material.
Cryogenic Thermal Absorptance Measurements on Small-Diameter Stainless Steel Tubing
NASA Technical Reports Server (NTRS)
Tuttle, James; Jahromi, Amir; Canavan, Edgar; DiPirro, Michael
2015-01-01
The Mid Infrared Instrument (MIRI) on the James Webb Space Telescope includes a mechanical cryocooler which cools its detectors to their 6 Kelvin operating temperature. The coolant gas flows through several meters of small-diameter stainless steel tubing, which is exposed to thermal radiation from its environment. Over much of its length this tubing is gold-plated to minimize the absorption of this radiant heat. In order to confirm that the cryocooler will meet MIRI's requirements, the thermal absorptance of this tubing was measured as a function of its environment temperature. We describe the measurement technique and present the results.
Hypersonic Wake Diagnostics Using Laser Induced Fluorescence Techniques
NASA Technical Reports Server (NTRS)
Mills, Jack L.; Sukenik, Charles I.; Balla, Robert J.
2011-01-01
A review of recent research performed in iodine that involves a two photon absorption of light at 193 nm will be discussed, and it's potential application to velocimetry measurements in a hypersonic flow field will be described. An alternative seed atom, Krypton, will be presented as a good candidate for performing nonintrusive hypersonic flow diagnostics. Krypton has a metastable state with a lifetime of approximately 43 s which would prove useful for time of flight measurement (TOF) and a sensitivity to collisions that can be utilized for density measurements. Calculations using modest laser energies and experimental values show an efficiency of excited state production to be on the order of 10(exp -6) for a two photon absorption at 193 nm.
Numerical study for heat generation/absorption in flow of nanofluid by a rotating disk
NASA Astrophysics Data System (ADS)
Aziz, Arsalan; Alsaedi, Ahmed; Muhammad, Taseer; Hayat, Tasawar
2018-03-01
Here MHD three-dimensional flow of viscous nanoliquid by a rotating disk with heat generation/absorption and slip effects is addressed. Thermophoresis and random motion features are also incorporated. Velocity, temperature and concentration slip conditions are imposed at boundary. Applied magnetic field is utilized. Low magnetic Reynolds number and boundary layer approximations have been employed in the problem formulation. Suitable transformations lead to strong nonlinear ordinary differential system. The obtained nonlinear system is solved numerically through NDSolve technique. Graphs have been sketched in order to analyze that how the velocity, temperature and concentration fields are affected by various pertinent variables. Moreover the numerical values for rates of heat and mass transfer have been tabulated and discussed.
Imaging efficiency of an X-ray contrast agent-incorporated polymeric microparticle.
Ahn, Sungsook; Jung, Sung Yong; Lee, Jin Pyung; Lee, Sang Joon
2011-01-01
Biocompatible polymeric encapsulants have been widely used as a delivery vehicle for a variety of drugs and imaging agents. In this study, X-ray contrast agent (iopamidol) is encapsulated into a polymeric microparticle (polyvinyl alcohol) as a particulate flow tracer in synchrotron X-ray imaging system. The physical properties of the designed microparticles are investigated and correlated with enhancement in the imaging efficiency by experimental observation and theoretical interpretation. The X-ray absorption ability of the designed microparticle is assessed by Beer-Lambert-Bouguer law. Particle size, either in dried state or in solvent, primarily dominates the X-ray absorption ability under the given condition, thus affecting imaging efficiency of the designed X-ray contrast flow tracers. Copyright © 2011 John Wiley & Sons, Ltd.
NASA Technical Reports Server (NTRS)
Walberg, G.
1974-01-01
The present work describes a facility designed to validate the various aspects of radiative flow field theory, including the absorption of shock layer radiation by ablation products. The facility is capable of producing radiation with a spectrum similar to that of an entry vehicle shock layer and is designed to allow measurements at vacuum ultraviolet wavelengths where the most significant absorption by ablation products is predicted to occur. The design concept of the facility is presented along with results of theoretical analyses carried out to assess its research potential. Experimental data obtained during tests that simulated earth and Venusian entry and in which simulated ablation products were injected into the stagnation region flow field are discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cai, Weiwei; Kaminski, Clemens F., E-mail: cfk23@cam.ac.uk
2014-01-20
This paper proposes a technique that can simultaneously retrieve distributions of temperature, concentration of chemical species, and pressure based on broad bandwidth, frequency-agile tomographic absorption spectroscopy. The technique holds particular promise for the study of dynamic combusting flows. A proof-of-concept numerical demonstration is presented, using representative phantoms to model conditions typically prevailing in near-atmospheric or high pressure flames. The simulations reveal both the feasibility of the proposed technique and its robustness. Our calculations indicate precisions of ∼70 K at flame temperatures and ∼0.05 bars at high pressure from reconstructions featuring as much as 5% Gaussian noise in the projections.
Measurement of winds in Venus' upper mesosphere based on Doppler shifts of the 2.6-mm (C-12)O line
NASA Technical Reports Server (NTRS)
Shah, Kathryn P.; Muhleman, Duane O.; Berge, Glenn L.
1991-01-01
Venus observations conducted in 1988 at the first rotational transition of (C-12)O finely sampled this absorption line by means of a 32-channel filter bank; with this spatial and spectral resolution, it proved possible to measure Doppler shifts of the absorption line across the planet due to strong winds in Venus' upper mesosphere. The Doppler shifts change in a way that is indicative of westward horizontal winds. The radial wind speeds from the Doppler shifts were smoothed to reduce noise and then fitted in least-squares fashion to canonical forms of the lower atmosphere's westward zonal flow. The two flows exhibit a high correlation in orientation.
Effect of air velocity and direction for indirect evaporative cooling in tropical area
NASA Astrophysics Data System (ADS)
Ayodha Ajiwiguna, Tri; Nugraha Rismi, Fadhlin; Ramdlan Kirom, Mukhammad
2017-06-01
In this research, experimental study of heat absorption rate caused by indirect evaporative cooling is performed by varying the velocity and direction of air. The ambient is at average temperature and relative humidity of 28.7 °C and 78% respectively. The experiment is conducted by attaching wet medium on the top of material reference plate with the dimension of 14 x 8 cm with 5 mm thickness. To get evaporative cooling effect, the air flow is directed to the wet medium with velocity from 1.6 m/s to 3.4 m/s with the increment of 0.2 m/s. The direction of air is set 0° (parallel), 45° (inclined), and 90° (perpendicular) to the wet medium surface. While the experiment is being performed, the air temperature, top and bottom of plate temperature are measured simultaneously after steady state condition is established. Based on the measurement result, heat absorption is calculated by analysing the heat conduction on the material reference. The result shows that the heat absorption rate is increased by higher velocity. Perpendicular direction of air flow results the highest cooling capacity compared with other direction. The maximum heat absorption rate is achieved at 13.9 Watt with 3.4 m/s velocity and perpendicular direction of air.
Simulation of a 20-ton LiBr/H{sub 2}O absorption cooling system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wardono, B.; Nelson, R.M.
The possibility of using solar energy as the main heat input for cooling systems has led to several studies of available cooling technologies that use solar energy. The results show that double-effect absorption cooling systems give relatively high performance. To further study absorption cooling systems, a computer code was developed for a double-effect lithium bromide/water (LiBr/H{sub 2}O) absorption system. To evaluate the performance, two objective functions were developed including the coefficient of performance (COP) and the system cost. Based on the system cost, an optimization to find the minimum cost was performed to determine the nominal heat transfer areas ofmore » each heat exchanger. The nominal values of other system variables, such as the mass flow rates and inlet temperatures of the hot water, cooling water, and chilled water, are specified as commonly used values for commercial machines. The results of the optimization show that there are optimum heat transfer areas. In this study, hot water is used as the main energy input. Using a constant load of 20 tons cooling capacity, the effects of various variables including the heat transfer ares, mass flow rates, and inlet temperatures of hot water, cooling water, and chilled water are presented.« less
NASA Astrophysics Data System (ADS)
Jagodzinski, Jeremy James
2007-12-01
The development to date of a diode-laser based velocimeter providing point-velocity-measurements in unseeded flows using molecular Rayleigh scattering is discussed. The velocimeter is based on modulated filtered Rayleigh scattering (MFRS), a novel variation of filtered Rayleigh scattering (FRS), utilizing modulated absorption spectroscopy techniques to detect a strong absorption of a relatively weak Rayleigh scattered signal. A rubidium (Rb) vapor filter is used to provide the relatively strong absorption; alkali metal vapors have a high optical depth at modest vapor pressures, and their narrow linewidth is ideally suited for high-resolution velocimetry. Semiconductor diode lasers are used to generate the relatively weak Rayleigh scattered signal; due to their compact, rugged construction diode lasers are ideally suited for the environmental extremes encountered in many experiments. The MFRS technique utilizes the frequency-tuning capability of diode lasers to implement a homodyne detection scheme using lock-in amplifiers. The optical frequency of the diode-based laser system used to interrogate the flow is rapidly modulated about a reference frequency in the D2-line of Rb. The frequency modulation is imposed on the Rayleigh scattered light that is collected from the probe volume in the flow under investigation. The collected frequency modulating Rayleigh scattered light is transmitted through a Rb vapor filter before being detected. The detected modulated absorption signal is fed to two lock-in amplifers synchronized with the modulation frequency of the source laser. High levels of background rejection are attained since the lock-ins are both frequency and phase selective. The two lock-in amplifiers extract different Fourier components of the detected modulated absorption signal, which are ratioed to provide an intensity normalized frequency dependent signal from a single detector. A Doppler frequency shift in the collected Rayleigh scattered light due to a change in the velocity of the flow under investigation results in a change in the detected modulated absorption signal. This change in the detected signal provides a quantifiable measure of the Doppler frequency shift, and hence the velocity in the probe volume, provided that the laser source exhibits acceptable levels of frequency stability (determined by the magnitude of the velocities being measured). An extended cavity diode laser (ECDL) in the Littrow configuration provides frequency tunable, relatively narrow-linewidth lasing for the MFRS velocimeter. Frequency stabilization of the ECDL is provided by a proportional-integral-differential (PID) controller based on an error signal in the reference arm of the experiment. The optical power of the Littrow laser source is amplified by an antireflection coated (AR coated) broad stripe diode laser. The single-mode, frequency-modulatable, frequency-stable O(50 mW) of optical power provided by this extended cavity diode laser master oscillator power amplifier (ECDL-MOPA) system provided sufficient scattering signal from a condensing jet of CO2 to implement the MFRS technique in the frequency-locked mode of operation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mathur, Jyotirmay; Bhandari, Mahabir S; Jain, Robin
Radiant cooling system has proven to be a low energy consumption system for building cooling needs. This study describes the use of cooling tower in radiant cooling system to improve the overall system efficiency. A comprehensive simulation feasibility study of the application of cooling tower in radiant cooling system was performed for the fifteen cities in different climatic zones of India. It was found that in summer, the wet bulb temperature (WBT) of the different climatic zones except warm-humid is suitable for the integration of cooling tower with radiant cooling system. In these climates, cooling tower can provide on averagemore » 24 C to 27 C water In order to achieve the energy saving potential, three different configurations of radiant cooling system have been compared in terms of energy consumption. The different configurations of the radiant cooling system integrated with cooling tower are: (1) provide chilled water to the floor, wall and ceiling mounted tubular installation. (2) provide chilled water to the wall and ceiling mounted tabular installation. In this arrangement a separate chiller has also been used to provide chilled water at 16 C to the floor mounted tubular installation. (3) provide chilled water to the wall mounted tabular installation and a separate chiller is used to provide chilled water at 16 C to the floor and ceiling mounted tabular installation. A dedicated outdoor air system is also coupled for dehumidification and ventilation in all three configurations. A conventional all-air system was simulated as a baseline to compare these configurations for assessing the energy saving potential.« less
Chylkova, Tereza; Cadena, Myrna; Ferreiro, Aura; Pitesky, Maurice
2017-07-01
Poultry contaminated with Salmonella enterica subsp. enterica are a major cause of zoonotic foodborne gastroenteritis. Salmonella Heidelberg is a common serotype of Salmonella that has been implicated as a foodborne pathogen associated with the consumption of improperly prepared chicken. To better understand the effectiveness of common antimicrobial disinfectants (i.e., peroxyacetic acid [PAA], acidified hypochlorite [aCH], and cetylpyridinium chloride [CPC]), environmental isolates of nontyphoidal Salmonella were exposed to these agents under temperature, concentration, and contact time conditions consistent with poultry processing. Under simulated processing conditions (i.e., chiller tank and dipping stations), the bacteriostatic and bactericidal effects of each disinfectant were assessed against biofilm and planktonic cultures of each organism in a disinfectant challenge. Log reductions, planktonic MICs, and mean biofilm eradication concentrations were computed. The biofilms of each Salmonella isolate were more resistant to the disinfectants than were their planktonic counterparts. Although PAA was bacteriostatic and bactericidal against the biofilm and planktonic Salmonella isolates tested at concentrations up to 64 times the concentrations commonly used in a chiller tank during poultry processing, aCH was ineffective against the same isolates under identical conditions. At the simulated 8-s dipping station, CPC was bacteriostatic against all seven and bactericidal against six of the seven Salmonella isolates in their biofilm forms at concentrations within the regulatory range. These results indicate that at the current contact times and concentrations, aCH and PAA are not effective against these Salmonella isolates in their biofilm state. The use of CPC should be considered as a tool for controlling Salmonella biofilms in poultry processing environments.
Bauermeister, L J; Bowers, J W J; Townsend, J C; McKee, S R
2008-11-01
Salmonella spp. and Campylobacter spp. continue to be prominent food safety concerns for the poultry industry and consumers alike. Peracetic acid (PAA) has been approved as an antimicrobial for use in poultry chillers. To validate its effectiveness, 100 poultry carcasses (per replication x 2) were inoculated with Salmonella (10(6) cfu) or Campylobacter (10(6) cfu) and were randomly allocated into chill water containing chlorine (0.003%) or PAA (0.0025%, 0.01%, or 0.02%). Results indicated that PAA concentrations as low as 0.0025% were effective in decreasing Salmonella spp., whereas PAA levels of 0.02% were effective in decreasing Campylobacter spp. when compared with the chlorine treatment. A sensory study was also conducted with another set of 500 carcasses (not inoculated). Birds were treated with water, chlorine (0.003%), or PAA (0.01%, 0.015%, or 0.02%). Sensory panels and microbial data were collected weekly on randomly sampled carcasses that were stored at 4 degrees C for 21 d. The PAA-treated carcasses at 0.015% and 0.02% had an extended shelf-life compared with those treated with water or chlorine. Specifically, on d 15, the only treatments that could be served to sensory panelists were the carcasses treated with 0.015% or 0.02% PAA. The carcasses treated with water, chlorine, or 0.01% PAA had off-colors, off-odors, and high microbial counts. These results suggest that PAA may be an effective antimicrobial when used in poultry chiller applications and greater levels (>or=0.015%) may extend product shelf-life.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sarker, M. R. I., E-mail: islamrabiul@yahoo.com; Saha, Manabendra, E-mail: manabendra.saha@adelaide.edu.au, E-mail: manab04me@gmail.com; Beg, R. A.
A recirculating flow solar particle cavity absorber (receiver) is modeled to investigate the flow behavior and heat transfer characteristics of a novel developing concept. It features a continuous recirculating flow of non-reacting metallic particles (black silicon carbide) with air which are used as a thermal enhancement medium. The aim of the present study is to numerically investigate the thermal behavior and flow characteristics of the proposed concept. The proposed solar particle receiver is modeled using two phase discrete particle model (DPM), RNG k-flow model and discrete ordinate (DO) radiation model. Numerical analysis is carried out considering a solar receiver withmore » only air and the mixture of non-reacting particles and air as a heat transfer as well as heat carrying medium. The parametric investigation is conducted considering the incident solar flux on the receiver aperture and changing air flow rate and recirculation rate inside the receiver. A stand-alone feature of the recirculating flow solar particle receiver concept is that the particles are directly exposed to concentrated solar radiation monotonously through recirculating flow inside the receiver and results in efficient irradiation absorption and convective heat transfer to air that help to achieve high temperature air and consequently increase in thermal efficiency. This paper presents, results from the developed concept and highlights its flow behavior and potential to enhance the heat transfer from metallic particles to air by maximizing heat carrying capacity of the heat transfer medium. The imposed milestones for the present system will be helpful to understand the radiation absorption mechanism of the particles in a recirculating flow based receiver, the thermal transport between the particles, the air and the cavity, and the fluid dynamics of the air and particle in the cavity.« less
Random Walks and Effective Optical Depth in Relativistic Flow
NASA Astrophysics Data System (ADS)
Shibata, Sanshiro; Tominaga, Nozomu; Tanaka, Masaomi
2014-05-01
We investigate the random walk process in relativistic flow. In the relativistic flow, photon propagation is concentrated in the direction of the flow velocity due to the relativistic beaming effect. We show that in the pure scattering case, the number of scatterings is proportional to the size parameter ξ ≡ L/l 0 if the flow velocity β ≡ v/c satisfies β/Γ Gt ξ-1, while it is proportional to ξ2 if β/Γ Lt ξ-1, where L and l 0 are the size of the system in the observer frame and the mean free path in the comoving frame, respectively. We also examine the photon propagation in the scattering and absorptive medium. We find that if the optical depth for absorption τa is considerably smaller than the optical depth for scattering τs (τa/τs Lt 1) and the flow velocity satisfies \\beta \\gg \\sqrt{2\\tau _a/\\tau _s}, then the effective optical depth is approximated by τ* ~= τa(1 + β)/β. Furthermore, we perform Monte Carlo simulations of radiative transfer and compare the results with the analytic expression for the number of scatterings. The analytic expression is consistent with the results of the numerical simulations. The expression derived in this study can be used to estimate the photon production site in relativistic phenomena, e.g., gamma-ray burst and active galactic nuclei.
NASA Astrophysics Data System (ADS)
Hayat, Tasawar; Qayyum, Sajid; Alsaedi, Ahmed; Ahmad, Bashir
2018-05-01
Main objective of present analysis is to study the magnetohydrodynamic (MHD) nonlinear convective flow of thixotropic nanofluid. Flow is due to nonlinear stretching surface with variable thickness. Nonlinear thermal radiation and heat generation/absorption are utilized in the energy expression. Convective conditions and zero mass flux at sheet are considered. Intention in present analysis is to develop a model for nanomaterial comprising Brownian motion and thermophoresis phenomena. Appropriate transformations are implemented for the conversion of partial differential systems into a sets of ordinary differential equations. The transformed expressions have been scrutinized through homotopic algorithm. Behavior of various sundry variables on velocity, temperature, nanoparticle concentration, skin friction coefficient and local Nusselt number are displayed through graphs. It is concluded that qualitative behaviors of temperature and thermal layer thickness are similar for radiation and temperature ratio variables. Moreover an enhancement in heat generation/absorption show rise to thermal field.
NASA Astrophysics Data System (ADS)
Weng, Chenyang; Boij, Susann; Hanifi, Ardeshir
2015-10-01
A numerical method for calculating the wavenumbers of axisymmetric plane waves in rigid-walled low-Mach-number turbulent flows is proposed, which is based on solving the linearized Navier-Stokes equations with an eddy-viscosity model. In addition, theoretical models for the wavenumbers are reviewed, and the main effects (the viscothermal effects, the mean flow convection and refraction effects, the turbulent absorption, and the moderate compressibility effects) which may influence the sound propagation are discussed. Compared to the theoretical models, the proposed numerical method has the advantage of potentially including more effects in the computed wavenumbers. The numerical results of the wavenumbers are compared with the reviewed theoretical models, as well as experimental data from the literature. It shows that the proposed numerical method can give satisfactory prediction of both the real part (phase shift) and the imaginary part (attenuation) of the measured wavenumbers, especially when the refraction effects or the turbulent absorption effects become important.
NASA Astrophysics Data System (ADS)
Liu, J. T. C.; Jeffries, J. B.; Hanson, R. K.
Multiplexed fiber-coupled diode lasers are used to probe second-harmonic line shapes of two near-infrared water absorption features, at 1343 nm and 1392 nm, in order to infer temperatures in gases containing water vapor, such as combustion flows. Wavelength modulation is performed at 170 kHz, and is superimposed on 1-kHz wavelength scans in order to recover full second-harmonic line shapes. Digital waveform generation and lock-in detection are performed using a data-acquisition card installed in a PC. An optimal selection of the modulation indices is shown to greatly simplify data interpretation over extended temperature ranges and to minimize the need for calibration when performing 2 f ratio thermometry. A theoretical discussion of this optimized strategy for 2 f ratio thermometry, as well as results from experimental validations in a heated cell, at pressures up to atmospheric, are presented in order to illustrate the utility of this technique for rapid temperature measurements in gaseous flow fields.
Gieseler, Henning; Kessler, William J; Finson, Michael; Davis, Steven J; Mulhall, Phillip A; Bons, Vincent; Debo, David J; Pikal, Michael J
2007-07-01
The goal of this work was to demonstrate the use of Tunable Diode Laser Absorption Spectroscopy (TDLAS) as a noninvasive method to continuously measure the water vapor concentration and the vapor flow velocity in the spool connecting a freeze-dryer chamber and condenser. The instantaneous measurements were used to determine the water vapor mass flow rate (g/s). The mass flow determinations provided a continuous measurement of the total amount of water removed. Full load runs of pure water at different pressure and shelf temperature settings and a 5% (w/w) mannitol product run were performed in both laboratory and pilot scale freeze dryers. The ratio of "gravimetric/TDLAS" measurements of water removed was 1.02 +/- 0.06. A theoretical heat transfer model was used to predict the mass flow rate and the model results were compared to both the gravimetric and TDLAS data. Good agreement was also observed in the "gravimetric/TDLAS" ratio for the 5% mannitol runs dried in both freeze dryers. The endpoints of primary and secondary drying for the product runs were clearly identified. Comparison of the velocity and mass flux profiles between the laboratory and pilot dryers indicated a higher restriction to mass flow for the lab scale freeze dryer. Copyright 2007 Wiley-Liss, Inc.
NASA Astrophysics Data System (ADS)
Khan, M. Ijaz; Hayat, Tasawar; Alsaedi, Ahmed
2018-02-01
This modeling and computations present the study of viscous fluid flow with variable properties by a rotating stretchable disk. Rotating flow is generated through nonlinear rotating stretching surface. Nonlinear thermal radiation and heat generation/absorption are studied. Flow is conducting for a constant applied magnetic field. No polarization is taken. Induced magnetic field is not taken into account. Attention is focused on the entropy generation rate and Bejan number. The entropy generation rate and Bejan number clearly depend on velocity and thermal fields. The von Kármán approach is utilized to convert the partial differential expressions into ordinary ones. These expressions are non-dimensionalized, and numerical results are obtained for flow variables. The effects of the magnetic parameter, Prandtl number, radiative parameter, heat generation/absorption parameter, and slip parameter on velocity and temperature fields as well as the entropy generation rate and Bejan number are discussed. Drag forces (radial and tangential) and heat transfer rates are calculated and discussed. Furthermore the entropy generation rate is a decreasing function of magnetic variable and Reynolds number. The Bejan number effect on the entropy generation rate is reverse to that of the magnetic variable. Also opposite behavior of heat transfers is observed for varying estimations of radiative and slip variables.
Cooling a solar telescope enclosure: plate coil thermal analysis
NASA Astrophysics Data System (ADS)
Gorman, Michael; Galapon, Chriselle; Montijo, Guillermo; Phelps, LeEllen; Murga, Gaizka
2016-08-01
The climate of Haleakalā requires the observatories to actively adapt to changing conditions in order to produce the best possible images. Observatories need to be maintained at a temperature closely matching ambient or the images become blurred and unusable. The Daniel K. Inouye Solar Telescope is a unique telescope as it will be active during the day as opposed to the other night-time stellar observatories. This means that it will not only need to constantly match the ever-changing temperature during the day, but also during the night so as not to sub-cool and affect the view field of other telescopes while they are in use. To accomplish this task, plate coil heat exchanger panels will be installed on the DKIST enclosure that are designed to keep the temperature at ambient temperature +0°C/-4°C. To verify the feasibility of this and to validate the design models, a test rig has been installed at the summit of Haleakalā. The project's purpose is to confirm that the plate coil panels are capable of maintaining this temperature throughout all seasons and involved collecting data sets of various variables including pressures, temperatures, coolant flows, solar radiations and wind velocities during typical operating hours. Using MATLAB, a script was written to observe the plate coil's thermal performance. The plate coil did not perform as expected, achieving a surface temperature that was generally 2ºC above ambient temperature. This isn't to say that the plate coil does not work, but the small chiller used for the experiment was undersized resulting in coolant pumped through the plate coil that was not supplied at a low enough temperature. Calculated heat depositions were about 23% lower than that used as the basis of the design for the hillers to be used on the full system, a reasonable agreement given the fact that many simplifying assumptions were used in the models. These were not carried over into the testing. The test rig performance showing a 23% margin provides a high degree of confidence for the performance of the full system when it is installed. If time allows, additional testing could be done that includes additional incident angles and times of day. This would allow a more complete analysis. If additional testing were to be performed, it's recommended to use a larger chiller capable of reaching lower temperatures. The test rig design could also be optimized in order to bring the plate coil up to its maximum efficiency. In the future, the script could be rewritten in a different computer language, so that the data could be solved for quicker. Further analysis could also include different types of coolants.
Radiation effects on beta /10.6/ of pure and europium doped KCl
NASA Technical Reports Server (NTRS)
Grimes, H. H.; Maisel, J. E.; Hartford, R. H.
1975-01-01
Changes in the optical absorption coefficient as the result of X-ray and electron bombardment of pure monocrystalline and polycrystalline KCl and of divalent europium doped polycrystalline KCl were determined. A constant heat flow calorimetric method was used to measure the optical absorption coefficients. Both 300 kV X-ray irradiation and 2 MeV electron irradiation produced increases in the optical absorption coefficient at room temperature. X-ray irradiation produced more significant changes in pure monocrystalline KCl than equivalent amounts of electron irradiation. Electron irradiation of pure and Eu-doped polycrystalline KCl produced increases in the absorption by as much as a factor of 20 over untreated material. Bleaching of the electron-irradiated doped KCl with 649 millimicron light produced a further increase.
Advancement of Double Effect Absorption Cycle by Input of Low Temperature Waste Heat
NASA Astrophysics Data System (ADS)
Kojima, Hiroshi; Edera, Masaru; Nakamura, Makoto; Oka, Masahiro; Akisawa, Atsushi; Kashiwagi, Takao
Energy conservation is becoming important for global environmental protection. New simple techniques of more efficient1y using the waste heat of gas co-generation systems for refrigerationare required. In first report, a new method of using the low temperature waste heat for refrigeration was proposed, and the basic characteristics of the promising methods of recovering waste heat were c1arified. In this report, the more detailed simulation model of the series flow type double effect absorption refrigerator with auxiliary heat exchanger was constructed and the static characteristics were investigated. Then experiments on this advanced absorption refrigerator were carried out, and the results of the calculation and experiments were compared and discussed. Moreover, the betterment of the simulation model of this advanced absorption refrigerator was carried out.
Absorption Kinetics of Subcutaneously Administered Ceftazidime in Hypoperfused Guinea Pigs.
Ebihara, Tsuyoshi; Oshima, Shinji; Okita, Mitsuyoshi; Shiina, Sayumi; Negishi, Akio; Ohara, Kousuke; Ohshima, Shigeru; Iwasaki, Hiroyuki; Yoneyama, Akira; Kitazumi, Eiji; Kobayashi, Daisuke
2015-12-01
Pneumonia is the most common cause of death in patients with severe motor and intellectual disabilities (SMID), and intravenous ceftazidime (CAZ) is a widely used treatment for such infections. However, intravenous administration in patients with SMID may be difficult because of insufficient vascular development. The aim of our study was to determine the feasibility of subcutaneous drug administration by mentholated warm compresses (WMCs) as an alternative delivery method for ceftazidime in patients with SMID. CAZ was subcutaneously administered to the abdominal region of naphazoline-treated hypoperfused guinea pigs, which were used as a hemodynamic model of patients with SMID. MWCs or warm compresses (WCs) were applied to the injection site to increase blood flow. We calculated the cumulative CAZ absorption over time by using the deconvolution method. Application of MWCs or WCs increased blood flow at the administration site and increased CAZ plasma levels. Application of MWCs or WCs after subcutaneous CAZ injection led to higher CAZ plasma levels than the mutant prevention concentration for a longer period than was observed for CAZ administration without the application of MWCs or WCs. The application of MWCs or WCs enhanced subcutaneous CAZ absorption by increasing blood flow. MWCs and WCs are considered to be safe and routine methods to induce defecation after surgery on the digestive system; thus, the combination of these methods and subcutaneous CAZ administration is a potential method for treating pneumonia in patients with SMID.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoekman, S. Kent; Broch, Broch; Robbins, Curtis
The primary objective of this project was to utilize a flexible, energy-efficient facility, called the DRI Renewable Energy Experimental Facility (REEF) to support various renewable energy research and development (R&D) efforts, along with education and outreach activities. The REEF itself consists of two separate buildings: (1) a 1200-ft2 off-grid capable house and (2) a 600-ft2 workshop/garage to support larger-scale experimental work. Numerous enhancements were made to DRI's existing renewable power generation systems, and several additional components were incorporated to support operation of the REEF House. The power demands of this house are satisfied by integrating and controlling PV arrays, solarmore » thermal systems, wind turbines, an electrolyzer for renewable hydrogen production, a gaseous-fuel internal combustion engine/generator set, and other components. Cooling needs of the REEF House are satisfied by an absorption chiller, driven by solar thermal collectors. The REEF Workshop includes a unique, solar air collector system that is integrated into the roof structure. This system provides space heating inside the Workshop, as well as a hot water supply. The Workshop houses a custom-designed process development unit (PDU) that is used to convert woody biomass into a friable, hydrophobic char that has physical and chemical properties similar to low grade coal. Besides providing sufficient space for operation of this PDU, the REEF Workshop supplies hot water that is used in the biomass treatment process. The DRI-REEF serves as a working laboratory for evaluating and optimizing the performance of renewable energy components within an integrated, residential-like setting. The modular nature of the system allows for exploring alternative configurations and control strategies. This experimental test bed is also highly valuable as an education and outreach tool both in providing an infrastructure for student research projects, and in highlighting renewable energy features to the public.« less
Solar cooling in Madrid: Available solar energy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Izquierdo, M.; Hernandez, F.; Martin, E.
1994-11-01
This paper analyzes the behaviour of an absorption chiller lithium bromide installation fed by a field of flat-plate solar collectors and condensed by swimming pool water. A method of calculation in a variable regime is developed in terms of the obtained experimental results. Starting from the meteorological variables of a clear summer day and from the project data (collector normalization curve, collector and installation mass), the minimum solar radiation level necessary to initiate the process, I[sub min], and the instantaneous available solar energy, Q[sub u] + W[sub 1] is determined. The solar radiation threshold, I[sub min], necessary to obtain themore » process temperature, t[sub ave], in each instant, is obtained by adding to the corrected Klein radiation threshold, I[sub k,c], the heat capacity effects of the collector, HCE[sub CO], and of the installation, HCE[sub ins], as well as the losses of heat of the pipes to the surroundings, Q[sub 1]. The instantaneous available solar energy, available useful heat, in addition to the wind collector losses to the surroundings, Q[sub u] + W[sub 1], is the difference, in each instant, between the radiation, I[sub g1T], and the radiation threshold, I[sub min].The integration during the day of the instantaneous available solar energy allows us to calculate the daily available function, H[sub T]. The value of H[sub T], measured in the swimming-pool water condensation installation reached 6.92 MJ/(m[sup 2] day ). The calculated values of H[sub T] for a conventional installation condensed by tower water, or air, have been 6.35 and 0.56 MJ/(m[sup 2] day). respectively.« less
Infrared radiative energy transfer in gaseous systems
NASA Technical Reports Server (NTRS)
Tiwari, Surendra N.
1991-01-01
Analyses and numerical procedures are presented to investigate the radiative interactions in various energy transfer processes in gaseous systems. Both gray and non-gray radiative formulations for absorption and emission by molecular gases are presented. The gray gas formulations are based on the Planck mean absorption coefficient and the non-gray formulations are based on the wide band model correlations for molecular absorption. Various relations for the radiative flux and divergence of radiative flux are developed. These are useful for different flow conditions and physical problems. Specific plans for obtaining extensive results for different cases are presented. The procedure developed was applied to several realistic problems. Results of selected studies are presented.
Caswell, Andrew W; Roy, Sukesh; An, Xinliang; Sanders, Scott T; Schauer, Frederick R; Gord, James R
2013-04-20
Hyperspectral absorption spectroscopy is being used to monitor gas temperature, velocity, pressure, and H(2)O mole fraction in a research-grade pulsed-detonation combustor (PDC) at the Air Force Research Laboratory. The hyperspectral source employed is termed the TDM 3-FDML because it consists of three time-division-multiplexed (TDM) Fourier-domain mode-locked (FDML) lasers. This optical-fiber-based source monitors sufficient spectral information in the H(2)O absorption spectrum near 1350 nm to permit measurements over the wide range of conditions encountered throughout the PDC cycle. Doppler velocimetry based on absorption features is accomplished using a counterpropagating beam approach that is designed to minimize common-mode flow noise. The PDC in this study is operated in two configurations: one in which the combustion tube exhausts directly to the ambient environment and another in which it feeds an automotive-style turbocharger to assess the performance of a detonation-driven turbine. Because the enthalpy flow [kilojoule/second] is important in assessing the performance of the PDC in various configurations, it is calculated from the measured gas properties.
Measurement of gas viscosity using photonic crystal fiber
NASA Astrophysics Data System (ADS)
Gao, R.-K.; Sheehe, S. L.; Kurtz, J.; O'Byrne, S.
2016-11-01
A new measurement technique for gas viscosity coefficient is designed and demonstrated using the technique of tunable diode laser absorption spectroscopy (TDLAS). Gas flow is driven by a pressure gradient between two gas cells, through a photonic crystal fiber (PCF) surrounded by a furnace for temperature adjustment. PCF with 20-micron diameter affords physical space for gas-light interaction and provides a basis for gas viscosity measurement by determining the time for flow to exit a capillary tube under the influence of a pressure gradient. Infrared radiation from a diode laser is coupled into the fiber to be guided through the gas, and the light attenuation due to absorption from the molecular absorbing species is measured by a photo detector placed at the exit of the fiber. A numerical model from Sharipov and Graur describing local number density distribution in a unsteady state is applied for the determination of gas viscosity, based on the number density of gas measured by the absorption of the laser light, using the Beer-Lambert law. The measurement system is confirmed by measuring the viscosity of CO2 as a reference gas.
Spray generators for absorption refrigeration systems
Sibley, Howard W.
1979-06-19
A spray generator for an absorption refrigeration system that includes a heat exchanger comprised of a multiplicity of variably spaced heat exchange tubes. The tubes are spaced close together near the top of the heat exchanger and spaced more widely apart near the bottom of the heat exchanger. Dilute absorbent solution is sprayed down through the heat exchanger. The close nesting of the tubes in the top portion of the heat exchanger retards liquid flow and aids heating of the solution. The wide spacing of the tubes in the lower section of the heat exchanger facilitate vapor flow out of the heat exchanger and eliminates liquid "blow-off". The top tubes are covered by a baffle to prevent the liquid solution from splashing out of the heat exchanger off of these top tubes.
NASA Astrophysics Data System (ADS)
Murphy, James; Jones, Phil; Hill, Steve J.
1996-12-01
A simple and accurate method has been developed for the determination of total mercury in environmental and biological samples. The method utilises an off-line microwave digestion stage followed by analysis using a flow injection system with detection by cold vapour atomic absorption spectrometry. The method has been validated using two certified reference materials (DORM-1 dogfish and MESS-2 estuarine sediment) and the results agreed well with the certified values. A detection limit of 0.2 ng g -1 Hg was obtained and no significant interference was observed. The method was finally applied to the determination of mercury in river sediments and canned tuna fish, and gave results in the range 0.1-3.0 mg kg -1.
ERIC Educational Resources Information Center
Fischer, Helen; Gonzalez, Cleotilde
2016-01-01
Stocks and flows (SF) are building blocks of dynamic systems: Stocks change through inflows and outflows, such as our bank balance changing with withdrawals and deposits, or atmospheric CO[subscript 2] with absorptions and emissions. However, people make systematic errors when trying to infer the behavior of dynamic systems, termed SF failure,…
Leal, L O; Elsholz, O; Forteza, R; Cerdà, V
2006-07-28
A new software-controlled time-based multisyringe flow injection system for mercury determination by cold-vapor atomic absorption spectrometry is proposed. Precise known volumes of sample, reducing agent (1.1% SnCl2 in 3% HCl) and carrier (3% HCl) are dispensed into a gas-liquid separation cell with a multisyringe burette coupled with one three-way solenoid valve. An argon flow delivers the reduced mercury to the spectrometer. The optimization of the system was carried out testing reaction coils and gas-liquid separators of different design as well as changing parameters, such as sample and reagents volumes, reagent concentrations and carrier gas flow rate, among others. The analytical curves were obtained within the range 50-5000 ng L(-1). The detection limit (3sigma(b)/S) achieved is 5 ng L(-1). The relative standard deviation (R.S.D.) was 1.4%, evaluated from 16 successive injections of 250 ng L(-1) Hg standard solution. The injection and sample throughput per hour were 44 and 11, respectively. This technique was validated by means of solid and water reference materials with good agreement with the certified values and was successfully applied to fish samples.
Measurements of gas temperature in a radiatively heated particle laden turbulent duct flow
NASA Astrophysics Data System (ADS)
Kim, Ji Hoon; Banko, Andrew; Villafane, Laura; Elkins, Chris; Eaton, John
2017-11-01
Predicting the absorption of radiation through a turbulent, particle laden flow is relevant in atmospheric sciences, turbulent combustion, and in the design of a particle solar receivers. In order to better understand the coupling between the particle phase, the turbulent fluid phase, and the incident radiation, the effects of radiation absorption by disperse inertial particles in a turbulent duct flow was studied experimentally. A fully-developed turbulent duct flow at Reynolds numbers of O(104) , laden with particles at mass loading ratios of 0.1-0.8, was subject to infrared radiation at varying incident powers. The particle Stokes number based on the Kolmogorov length scale was approximately 12, resulting in a preferentially concentrated particle phase. Measurements of the mean and fluctuating components of the gas phase temperature were made along the wall bisector. Results from mean temperature traverses of the gas phase show that a one-dimensional model can account for much of the mean gas temperature rise. Temperature fluctuations due to preferential concentration are significant and can reach approximately 50% of the mean temperature rise. This work was funded by the U.S. Department of Energy under Grant No. DE-NA0002373-1.
Mudalige, Thilak K; Qu, Haiou; Linder, Sean W
2015-11-13
Engineered nanoparticles are available in large numbers of commercial products claiming various health benefits. Nanoparticle absorption, distribution, metabolism, excretion, and toxicity in a biological system are dependent on particle size, thus the determination of size and size distribution is essential for full characterization. Number based average size and size distribution is a major parameter for full characterization of the nanoparticle. In the case of polydispersed samples, large numbers of particles are needed to obtain accurate size distribution data. Herein, we report a rapid methodology, demonstrating improved nanoparticle recovery and excellent size resolution, for the characterization of gold nanoparticles in dietary supplements using asymmetric flow field flow fractionation coupled with visible absorption spectrometry and inductively coupled plasma mass spectrometry. A linear relationship between gold nanoparticle size and retention times was observed, and used for characterization of unknown samples. The particle size results from unknown samples were compared to results from traditional size analysis by transmission electron microscopy, and found to have less than a 5% deviation in size for unknown product over the size range from 7 to 30 nm. Published by Elsevier B.V.
Gentilcore, Diana; Vanis, Lora; Wishart, Judith M; Rayner, Christopher K; Horowitz, Michael; Jones, Karen L
2011-08-01
Postprandial hypotension is an important problem in the elderly and may be triggered by the increase in splanchnic blood flow induced by a meal. Acarbose attenuates the fall in blood pressure (BP) induced by oral sucrose and may be useful in the management of postprandial hypotension. It is not known whether the effect of acarbose on postprandial BP reflects slowing of gastric emptying and/or carbohydrate absorption nor whether acarbose affects splanchnic blood flow. We examined the effects of intraduodenal (ID) acarbose on the BP, heart rate, superior mesenteric artery (SMA) flow, and glycemic and insulin responses to ID sucrose in older participants--this approach excluded any "gastric" effect of acarbose. Eight healthy participants (four male and four female, age 66-77 years) received an ID infusion of sucrose (~6 kcal/min), with or without acarbose (100 mg), over 60 minutes. BP, heart rate, SMA flow, blood glucose, and serum insulin were measured. Acarbose markedly attenuated the falls in systolic (p < .01) and diastolic (p < .05) BP and rises in heart rate (p < .05), SMA flow (p < .05), blood glucose (p < .01), and serum insulin (p < .05). The maximum fall in systolic BP and peak SMA flow was inversely related on the control day (r(2) = -.53, p < .05) but not with acarbose (r(2) = .03, p = .70). We conclude that in healthy older participants receiving ID sucrose, (a) acarbose markedly attenuates the hypotensive response by slowing carbohydrate absorption and attenuating the rise in splanchnic blood flow and (b) the fall in BP is related to the concomitant increase in SMA flow.
Xia, Yan; Li, Ming; Kučerka, Norbert; Li, Shutao; Nieh, Mu-Ping
2015-02-01
We have designed and constructed a temperature-controllable shear flow cell for in-situ study on flow alignable systems. The device has been tested in the neutron diffraction and has the potential to be applied in the small angle neutron scattering configuration to characterize the nanostructures of the materials under flow. The required sample amount is as small as 1 ml. The shear rate on the sample is controlled by the flow rate produced by an external pump and can potentially vary from 0.11 to 3.8 × 10(5) s(-1). Both unidirectional and oscillational flows are achievable by the setting of the pump. The instrument is validated by using a lipid bicellar mixture, which yields non-alignable nanodisc-like bicelles at low T and shear-alignable membranes at high T. Using the shear cell, the bicellar membranes can be aligned at 31 °C under the flow with a shear rate of 11.11 s(-1). Multiple high-order Bragg peaks are observed and the full width at half maximum of the "rocking curve" around the Bragg's condition is found to be 3.5°-4.1°. It is noteworthy that a portion of the membranes remains aligned even after the flow stops. Detailed and comprehensive intensity correction for the rocking curve has been derived based on the finite rectangular sample geometry and the absorption of the neutrons as a function of sample angle [See supplementary material at http://dx.doi.org/10.1063/1.4908165 for the detailed derivation of the absorption correction]. The device offers a new capability to study the conformational or orientational anisotropy of the solvated macromolecules or aggregates induced by the hydrodynamic interaction in a flow field.
Diode Laser Sensors for Arc-Jet Characterization
NASA Technical Reports Server (NTRS)
Hanson, Ronald K.
2005-01-01
The development and application of tunable diode laser (TDL) absorption sensors to monitor the health and operating conditions in the large-scale 60 MW arc-heated- plasma wind-tunnel at NASA Ames Research Center is reported. The interactive heating facility (THF) produces re-entry flow conditions by expanding the gas heated in a constricted plasma arc-heater to flow at high velocity over a model located in a test cabin. This facility provides the conditions needed to test thermal protective systems for spacecraft re-entering the earth s atmosphere. TDL sensors are developed to monitor gas flows in both the high-temperature constricted flow and the supersonic expansion flow into test cabin. These sensors utilize wavelength-tuned diode lasers to measure absorption transitions of atomic oxygen near 777.2 nm, atomic nitrogen near 856.8 nm, and atomic copper near 793.3 nm. The oxygen and nitrogen sensors measure the population density in exited electronic states of these atoms. The measurements combined with the assumption of local thermal and chemical equilibrium yield gas temperature (typically near 7,000K). The nitrogen and oxygen population temperatures are redundant, and their close agreement provides an important test of the local thermal equilibrium assumption. These temperature sensors provide time-resolved monitors of the operating conditions of the arc-heater and can be used to verify and control the test conditions. An additional TDL sensor was developed to monitor the copper concentration in the arc-heater flow yielding values as high as 13 ppm. Measurements of copper in the flow can identify flow conditions with unacceptably rapid electrode erosion, and hence this sensor provides valuable information needed to schedule maintenance to avoid costly arc-heater failure. TDL sensors were also developed for measurements in the test cabin, where absorption measurements of the populations of argon and molecular nitrogen in excited metastable electronic states established that the number density of these excited species is much lower than estimated using frozen-chemistry approximations. This key finding suggests that in the post-expansion region there is not a significant energy sequestration in electronically excited species. Finally, TDL measurements of atomic potassium seeded into the test cabin flow were used to directly measure the static temperature of the test gas. The results of this study illustrate the high potential of time-resolved TDL measurements for routine and economical sensing of arc-heater health (gas temperature and electrode erosion) as well as the time-resolved test-cabin-flow conditions in front of the model.
Energy management system saves $250,000 + fuel -with 4-mo payback
DOE Office of Scientific and Technical Information (OSTI.GOV)
Massey, C.L.; Robe, K.
1980-09-01
Innovations made at Hershey Chocolate Company's Oakdale, California plant eliminated simultaneous cool-reheat-cycles by incorporating dead band controls into existing HVAC systems. Calculated savings of the project are about 90% of former heating and cooling energy usage for HVAC operation. Electric power savings amount to about $75,000/y, and natural gas savings about $185,000/y, using 1980 fuel costs, with an approximate 4-month payback. Because of the reduced demand for chilled water, a smaller water chiller carries full plant load for 4 to 5 months of the year without operating two existing 500-ton units.
1988-07-01
of a Eutectic Salt System 16 0 11 Energy Characteristics of Fort Stewart PX on a Hot Day 21 12 Peak Day Load Profile for Fort Stewart 21 13 Chiller...at Yuma Proving Ground, AZ in FY 88. An ice-shucking and a eutectic salt DIS cooling system are scheduled to be installed in the coming years. The...water, ice, or freezing eutectic salt . Ice and salt systems can be grouped • together as phase-change systems. In a recent survey of over a hundred
2. View, structures in Systems Integration Laboratory complex, looking north. ...
2. View, structures in Systems Integration Laboratory complex, looking north. The Components Test Laboratory (T-27) is located in the immediate foreground. Immediately uphill to the left of T-27 is the Boiler Chiller Plant (T-28H). To the left of T-28H is the Oxidizer Conditioning Structure (T-28D). Behind the T-28D is the Long-Term Oxidizer Silo (T-28B). The twin gantry structure at the left is the Systems Integration Laboratory (T-28). - Air Force Plant PJKS, Systems Integration Laboratory, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO
Feasibility analysis of reciprocating magnetic heat pumps
NASA Technical Reports Server (NTRS)
Larson, A. V.; Hartley, J. G.; Shelton, Sam V.; Smith, M. M.
1989-01-01
A reciprocating gadolinium core in a regeneration fluid column in the warm bore of a superconducting solenoidal magnet is considered for magnetic refrigeration in 3.517 MW (1000 ton) applications. A procedure is presented to minimize the amount of superconducting cable needed in the magnet design. Estimated system capital costs for an ideal magnetic refrigerator of this type become comparable to conventional chillers as the frequency of reciprocation approaches 10 Hertz. A 1-D finite difference analysis of a regenerator cycling at 0.027 Hertz is presented which exhibits some of the features seen in the experiments of G. V. Brown.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gleason, T.C.J.
1992-06-01
The justification, strategies, and technology options for implementing advanced district heating and cooling systems in the United States are presented. The need for such systems is discussed in terms of global warming, ozone depletion, and the need for a sustainable energy policy. Strategies for implementation are presented in the context of the Public Utilities Regulatory Policies Act and proposed new institutional arrangements. Technology opportunities are highlighted in the areas of advanced block-scale cogeneration, CFC-free chiller technologies, and renewable sources of heating and cooling that are particularly applicable to district systems.
NASA Lewis Research Center photovoltaic application experiments
NASA Technical Reports Server (NTRS)
Ratajczak, A.; Bifano, W.; Martz, J.; Odonnell, P.
1978-01-01
The NASA Lewis Research Center has installed 16 geographically dispersed terrestrial photovoltaic systems as part of the DOE National Photovoltaic Program. Four additional experiments are in progress. Currently, operating systems are powering refrigerators, a highway warning sign, forest lookout towers, remote weather stations, a water chiller and insect survey traps. Experiments in progress include the world's first village power system, an air pollution monitor and seismic sensors. Under a separate activity, funded by the U.S. Agency for International Development, a PV-powered water pump and grain grinder is being prepared for an African village. System descriptions and status are included in this report.
1972-05-01
This wide-angle view depicts the Orbital Workshop (OWS) wardroom/galley located in the lower level of the OWS. The galley in the wardroom provided the daily supply of food; galley-located equipment was used for preparation and disposal of food. The Skylab astronauts used the wardroom as kitchen and dining room. The hexagonal food table, shown in the middle of this image, allowed three crewmen to simultaneously heat their food and eat their meals in an efficient and comfortable marner. Chairs were pointless in the zero-gravity environment. The table also supported components of the water system, including the water chiller and the wardroom water heater.
FPL official Laseter presents Center Director Bridges with a rebate check at KSC
NASA Technical Reports Server (NTRS)
1997-01-01
Larry Laseter (left), vice president of Sales and Marketing for the Florida Power & Light (FPL) Company, presents Kennedy Space Center (KSC) Director Roy Bridges Jr., with a rebate check for $195,000, recognizing KSC's commitment to reducing overall energy consumption and costs now and in the future. The energy savings realized by KSC come as a direct result of installing new chilled water systems hardware in the KSC Industrial Area Chiller Plant. KSC has received FPL rebates for its energy-saving efforts since 1993, but this check is the largest single-project rebate to date.
Waste heat driven absorption refrigeration process and system
Wilkinson, William H.
1982-01-01
Absorption cycle refrigeration processes and systems are provided which are driven by the sensible waste heat available from industrial processes and other sources. Systems are disclosed which provide a chilled water output which can be used for comfort conditioning or the like which utilize heat from sensible waste heat sources at temperatures of less than 170.degree. F. Countercurrent flow equipment is also provided to increase the efficiency of the systems and increase the utilization of available heat.
Duclos, B; Bories, P; Mathieu-Daude, J C; Michel, H
1991-01-01
Acute prehepatic portal hypertension induces intestinal secretion in animal models. In the course of chronic liver disease, however, these changes are not observed, despite higher portal pressures than those found in experimental studies. Eight patients without diarrhoea and with chronic alcoholic liver disease were examined for evidence of increased jejunal secretion; their suprahepatic wedge pressure was raised from 21 to 45 mmHg (mean 34.6 mmHg). Jejunal perfusion with a triple lumen catheter and a proximal occluding balloon was used to study net flows of water and chloride as well as net and unidirectional flows of sodium and potassium. No statistical difference in intestinal flows of water and electrolytes was noted between cirrhotic patients and control subjects after infusion with a 30 mmol/l glucose solution. Infusion with a 30 mmol/l mannitol solution resulted in a lower absorption of water, Na, K, and Cl than with the glucose solution. A higher rate of Na secretion was observed in cirrhotic patients than control subjects after infusion with 30 mmol/l mannitol (p less than 0.01). In addition, the rate of Na secretion was higher in cirrhotic patients than in control subjects (p less than 0.05). There was no correlation between the net flow of Na and the suprahepatic wedge pressure. A second perfusion with a 30 mmol/l glucose solution was given 75 minutes after a bolus injection of spironolactone (400 mg). Net flows of Na and Cl were lower in cirrhotic patients than in control subjects (p less than 0.05) because of a lower absorption of Na. Patients with gradually developing portal hypertension have moderate jejunal secretions of H2O and electrolytes which we assume are partly masked by increased absorption resulting from hyperaldosteronism. In contrast to animal models, this mechanism may be part of the jejunal adaptation to permeability in acute portal hypertension. PMID:2060871
Absorption Mode FT-ICR Mass Spectrometry Imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, Donald F.; Kilgour, David P.; Konijnenburg, Marco
2013-12-03
Fourier transform ion cyclotron resonance mass spectrometry offers the highest mass resolving power for molecular imaging experiments. This high mass resolving power ensures that closely spaced peaks at the same nominal mass are resolved for proper image generation. Typically higher magnetic fields are used to increase mass resolving power. However, a gain in mass resolving power can also be realized by phase correction of the data for absorption mode display. In addition to mass resolving power, absorption mode offers higher mass accuracy and signal-to-noise ratio over the conventional magnitude mode. Here we present the first use of absorption mode formore » Fourier transform ion cyclotron resonance mass spectrometry imaging. The Autophaser algorithm is used to phase correct each spectrum (pixel) in the image and then these parameters are used by the Chameleon work-flow based data processing software to generate absorption mode ?Datacubes? for image and spectral viewing. Absorption mode reveals new mass and spatial features that are not resolved in magnitude mode and results in improved selected ion image contrast.« less
NASA Astrophysics Data System (ADS)
Wang, Yanxing; Brasseur, James G.
2017-06-01
We evaluate the potential for physiological control of intestinal absorption by the generation of "micromixing layers" (MMLs) induced by coordinated motions of mucosal villi coupled with lumen-scale "macro" eddying motions generated by gut motility. To this end, we apply a three-dimensional (3D) multigrid lattice-Boltzmann model of a lid-driven macroscale cavity flow with microscale fingerlike protuberances at the lower surface. Integrated with a previous 2D study of leaflike villi, we generalize to 3D the 2D mechanisms found there to enhance nutrient absorption by controlled villi motility. In three dimensions, increased lateral spacing within villi within groups that move axially with the macroeddy reduces MML strength and absorptive enhancement relative to two dimensions. However, lateral villi motions create helical 3D particle trajectories that enhance absorption rate to the level of axially moving 2D leaflike villi. The 3D enhancements are associated with interesting fundamental adjustments to 2D micro-macro-motility coordination mechanisms and imply a refined potential for physiological or pharmaceutical control of intestinal absorption.
NASA Astrophysics Data System (ADS)
Zhou, J. Y.; Wang, B. F.; Nie, L. H.; Lu, J. X.; Hao, Y. J.; Xu, R. R.
2018-01-01
China’s oil dependence is getting higher and higher, 90% of oil import is transported by sea. Tankers will produce a lot of VOCs during loading and unloading, so the prevention of such pollution has become increasingly urgent. The hollow fiber membrane absorption method combined the characteristics of the absorption method for the treatment of high concentration and large flow of VOCs and the advantage of low energy consumption of membrane method. At present, the research on the recovery of oil and gas is relatively few. In this paper, the effect of membrane absorption on the recovery of oil and gas was investigated. The different absorbent affected the oil vapor recovery, the experimental results showed that the performance of absorbent of AbsFOV-97 was better than that of heat conductive oil.
Architecture for Absorption Based Heaters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moghaddam, Saeed; Chugh, Devesh
An absorption based heater is constructed on a fluid barrier heat exchanging plate such that it requires little space in a structure. The absorption based heater has a desorber, heat exchanger, and absorber sequentially placed on the fluid barrier heat exchanging plate. The vapor exchange faces of the desorber and the absorber are covered by a vapor permeable membrane that is permeable to a refrigerant vapor but impermeable to an absorbent. A process fluid flows on the side of the fluid barrier heat exchanging plate opposite the vapor exchange face through the absorber and subsequently through the heat exchanger. Themore » absorption based heater can include a second plate with a condenser situated parallel to the fluid barrier heat exchanging plate and opposing the desorber for condensation of the refrigerant for additional heating of the process fluid.« less
Heterogeneous porous structures for the fastest liquid absorption
NASA Astrophysics Data System (ADS)
Shou, Dahua; Ye, Lin; Fan, Jintu
2013-08-01
Engineered porous materials, which have fast absorption of liquids under global constraints (e.g. volume, surface area, or cost of the materials), are useful in many applications including moisture management fabrics, medical wound dressings, paper-based analytical devices, liquid molding composites, etc.. The absorption in capillary tubes and porous media is driven by the surface tension of liquid, which is inversely proportional to the pore size. On the contrary, the ability of conduction (or permeability) of liquid in porous materials is linear with the square of pore size. Both mechanisms superimpose with each other leading to a possibility of the fastest absorption for a porous structure. In this work, we explore the flow behaviors for the fastest absorption using heterogeneous porous architectures, from two-portion tubes to two-layer porous media. The absorption time for filling up the voids in these porous materials is expressed in terms of pore size, height and porosity. It is shown that under the given height and void volume, these two-component porous structures with a negative gradient of pore size/porosity against the imbibition direction, have a faster absorption rate than controlled samples with uniform pore size/porosity. Particularly, optimal structural parameters including pore size, height and porosity are found for the minimum absorption time. The obtained results will be used as a priori for the design of porous structures with excellent water absorption and moisture management property in various fields.
ERIC Educational Resources Information Center
Bittick, Sarah Joy; Chung, Gregory K. W. K.
2011-01-01
The use of a narrative in educational contexts has been found to increase learners' experience of flow or absorption in a task. This increased experience of flow can in turn result in increased retention and learning outcomes. However, narrative can also be polarizing particularly in the male-dominated realm of video game play due to gender…
Filtered Rayleigh Scattering Measurements in a Buoyant Flow Field
2008-03-01
ENY/08-M22 Abstract Filtered Rayleigh Scattering (FRS) is a non-intrusive, laser -based flow characterization technique that consists of a narrow...linewidth laser , a molecular absorption filter, and a high resolution camera behind the filter to record images. Gases of different species have...different molecular scattering cross-sections that become apparent as they pass through the interrogating laser light source, and this difference is
What is the true supply of amino acids for a dairy cow?
Lapierre, H; Pacheco, D; Berthiaume, R; Ouellet, D R; Schwab, C G; Dubreuil, P; Holtrop, G; Lobley, G E
2006-03-01
Improving the prediction of milk protein yield relies on knowledge of both protein supply and requirement. Definition of protein/amino acid supply in ruminants is a challenging task, due to feedstuff variety and variability and to the remodeling of nutrient intake by the rumen microflora. The questions arise, therefore, how and where should we measure the real supply of AA in the dairy cow? This review will follow the downstream flow of AA from duodenum to peripheral tissue delivery, with a glance at the efficiency of transfer into milk protein. Duodenal AA flow comprises rumen undegradable feed, microbial protein, and endogenous secretions. Most attention has been directed toward definition of the first two contributions but the latter fraction can represent as much as 20% of duodenal flow. More information is needed on what factors affect its magnitude and overall impact. Once digested, AA are absorbed into the portal vein. The ratio of portal absorption to small intestinal apparent digestion varies among essential AA, from 0.43 (threonine) to 0.76 (phenylalanine), due to the contributions of preduodenal endogenous secretions to the digestive flow, non-reabsorption of endogenous secretions and gut oxidation of AA. Few data are available on these phenomena in dairy cows but the evidence indicates that they alter the profile of AA available for anabolic purposes. Recent comparisons of estimated duodenal flux and measured portal flux have prompted a revisit of the NRC (2001) approach to estimate AA flows at the duodenum. Changes to the model are proposed that yield predictions that better fit the current knowledge of AA metabolism across the gut. After absorption, AA flow first to the liver where substantial and differential net removal occurs, varying from zero for the branched-chain AA to 50% of portal absorption for phenylalanine. This process alters the pattern of net supply to the mammary gland. Overall, intermediary metabolism of AA between the duodenum and the mammary gland biologically explains the decreased efficiency of the transfer of absorbed AA into milk protein as maximal yield is approached. Therefore, variable, rather than fixed, factors for transfer efficiencies must be incorporated into future predictive models.
Job characteristics, flow, and performance: the moderating role of conscientiousness.
Demerouti, Evangelia
2006-07-01
The present article aims to show the importance of positive work-related experiences within occupational health psychology by examining the relationship between flow at work (i.e., absorption, work enjoyment, and intrinsic work motivation) and job performance. On the basis of the literature, it was hypothesized that (a) motivating job characteristics are positively related to flow at work and (b) conscientiousness moderates the relationship between flow and other ratings of (in-role and out-of-role) performance. The hypotheses were tested on a sample of 113 employees from several occupations. Results of moderated structural equation modeling analyses generally supported the hypotheses. Motivating job characteristics were predictive of flow, and flow predicted in-role and extra-role performance, for only conscientious employees.
How is flow experienced and by whom? Testing flow among occupations.
Llorens, Susana; Salanova, Marisa; Rodríguez, Alma M
2013-04-01
The aims of this paper are to test (1) the factorial structure of the frequency of flow experience at work; (2) the flow analysis model in work settings by differentiating the frequency of flow and the frequency of its prerequisites; and (3) whether there are significant differences in the frequency of flow experience depending on the occupation. A retrospective study among 957 employees (474 tile workers and 483 secondary school teachers) using multigroup confirmatory factorial analyses and multiple analyses of variance suggested that on the basis of the flow analysis model in work settings, (1) the frequency of flow experience has a two-factor structure (enjoyment and absorption); (2) the frequency of flow experience at work is produced when both challenge and skills are high and balanced; and (3) secondary school teachers experience flow more frequently than tile workers. Copyright © 2012 John Wiley & Sons, Ltd.
Design, construction, and testing of the direct absorption receiver panel research experiment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chavez, J.M.; Rush, E.E.; Matthews, C.W.
1990-01-01
A panel research experiment (PRE) was designed, built, and tested as a scaled-down model of a direct absorption receiver (DAR). The PRE is a 3-MW{sub t}DAR experiment that will allow flow testing with molten nitrate salt and provide a test bed for DAR testing with actual solar heating. In a solar central receiver system DAR, the heat absorbing fluid (a blackened molten nitrate salt) flows in a thin film down a vertical panel (rather than through tubes as in conventional receiver designs) and absorbs the concentrated solar flux directly. The ability of the flowing salt film to absorb flux directly.more » The ability of the flowing salt film to absorb the incident solar flux depends on the panel design, hydraulic and thermal fluid flow characteristics, and fluid blackener properties. Testing of the PRE is being conducted to demonstrate the engineering feasibility of the DAR concept. The DAR concept is being investigated because it offers numerous potential performance and economic advantages for production of electricity when compared to other solar receiver designs. The PRE utilized a 1-m wide by 6-m long absorber panel. The salt flow tests are being used to investigate component performance, panel deformations, and fluid stability. Salt flow testing has demonstrated that all the DAR components work as designed and that there are fluid stability issues that need to be addressed. Future solar testing will include steady-state and transient experiments, thermal loss measurements, responses to severe flux and temperature gradients and determination of peak flux capability, and optimized operation. In this paper, we describe the design, construction, and some preliminary flow test results of the Panel Research Experiment. 11 refs., 8 figs., 2 tabs.« less
NASA Astrophysics Data System (ADS)
Rothensteiner, Matthäus; Jenni, Joel; Emerich, Hermann; Bonk, Alexander; Vogt, Ulrich F.; van Bokhoven, Jeroen A.
2017-08-01
An in situ/operando flow cell for transmission mode X-ray absorption spectroscopy (XAS), X-ray diffraction (XRD), and combined XAS/XRD measurements in a single experiment under the extreme conditions of two-step solar thermochemical looping for the dissociation of water and/or carbon dioxide was developed. The apparatus exposes materials to relevant conditions of both the auto-reduction and the oxidation sub-steps of the thermochemical cycle at ambient temperature up to 1773 K and enables determination of the composition of the effluent gases by online quadrupole mass spectrometry. The cell is based on a tube-in-tube design and is heated by means of a focusing infrared furnace. It was tested successfully for carbon dioxide splitting. In combined XAS/XRD experiments with an unfocused beam, XAS measurements were performed at the Ce K edge (40.4 keV) and XRD measurements at 64.8 keV and 55.9 keV. Furthermore, XRD measurements with a focused beam at 41.5 keV were carried out. Equimolar ceria-hafnia was auto-reduced in a flow of argon and chemically reduced in a flow of hydrogen/helium. Under reducing conditions, all cerium(iv) was converted to cerium(iii) and a cation-ordered pyrochlore-type structure was formed, which was not stable upon oxidation in a flow of carbon dioxide.
Rothensteiner, Matthäus; Jenni, Joel; Emerich, Hermann; Bonk, Alexander; Vogt, Ulrich F; van Bokhoven, Jeroen A
2017-08-01
An in situ/operando flow cell for transmission mode X-ray absorption spectroscopy (XAS), X-ray diffraction (XRD), and combined XAS/XRD measurements in a single experiment under the extreme conditions of two-step solar thermochemical looping for the dissociation of water and/or carbon dioxide was developed. The apparatus exposes materials to relevant conditions of both the auto-reduction and the oxidation sub-steps of the thermochemical cycle at ambient temperature up to 1773 K and enables determination of the composition of the effluent gases by online quadrupole mass spectrometry. The cell is based on a tube-in-tube design and is heated by means of a focusing infrared furnace. It was tested successfully for carbon dioxide splitting. In combined XAS/XRD experiments with an unfocused beam, XAS measurements were performed at the Ce K edge (40.4 keV) and XRD measurements at 64.8 keV and 55.9 keV. Furthermore, XRD measurements with a focused beam at 41.5 keV were carried out. Equimolar ceria-hafnia was auto-reduced in a flow of argon and chemically reduced in a flow of hydrogen/helium. Under reducing conditions, all cerium(iv) was converted to cerium(iii) and a cation-ordered pyrochlore-type structure was formed, which was not stable upon oxidation in a flow of carbon dioxide.