Correia, Rodolfo Patussi; Bento, Laiz Cameirão; Bortolucci, Ana Carolina Apelle; Alexandre, Anderson Marega; Vaz, Andressa da Costa; Schimidell, Daniela; Pedro, Eduardo de Carvalho; Perin, Fabricio Simões; Nozawa, Sonia Tsukasa; Mendes, Cláudio Ernesto Albers; Barroso, Rodrigo de Souza; Bacal, Nydia Strachman
2016-01-01
ABSTRACT Objective: To discuss the implementation of technical advances in laboratory diagnosis and monitoring of paroxysmal nocturnal hemoglobinuria for validation of high-sensitivity flow cytometry protocols. Methods: A retrospective study based on analysis of laboratory data from 745 patient samples submitted to flow cytometry for diagnosis and/or monitoring of paroxysmal nocturnal hemoglobinuria. Results: Implementation of technical advances reduced test costs and improved flow cytometry resolution for paroxysmal nocturnal hemoglobinuria clone detection. Conclusion: High-sensitivity flow cytometry allowed more sensitive determination of paroxysmal nocturnal hemoglobinuria clone type and size, particularly in samples with small clones. PMID:27759825
Alves, L P S; Almeida, A T; Cruz, L M; Pedrosa, F O; de Souza, E M; Chubatsu, L S; Müller-Santos, M; Valdameri, G
2017-01-16
The conventional method for quantification of polyhydroxyalkanoates based on whole-cell methanolysis and gas chromatography (GC) is laborious and time-consuming. In this work, a method based on flow cytometry of Nile red stained bacterial cells was established to quantify poly-3-hydroxybutyrate (PHB) production by the diazotrophic and plant-associated bacteria, Herbaspirillum seropedicae and Azospirillum brasilense. The method consists of three steps: i) cell permeabilization, ii) Nile red staining, and iii) analysis by flow cytometry. The method was optimized step-by-step and can be carried out in less than 5 min. The final results indicated a high correlation coefficient (R2=0.99) compared to a standard method based on methanolysis and GC. This method was successfully applied to the quantification of PHB in epiphytic bacteria isolated from rice roots.
Øbro, Nina F; Ryder, Lars P; Madsen, Hans O; Andersen, Mette K; Lausen, Birgitte; Hasle, Henrik; Schmiegelow, Kjeld; Marquart, Hanne V
2012-01-01
Reduction in minimal residual disease, measured by real-time quantitative PCR or flow cytometry, predicts prognosis in childhood B-cell precursor acute lymphoblastic leukemia. We explored whether cells reported as minimal residual disease by flow cytometry represent the malignant clone harboring clone-specific genomic markers (53 follow-up bone marrow samples from 28 children with B-cell precursor acute lymphoblastic leukemia). Cell populations (presumed leukemic and non-leukemic) were flow-sorted during standard flow cytometry-based minimal residual disease monitoring and explored by PCR and/or fluorescence in situ hybridization. We found good concordance between flow cytometry and genomic analyses in the individual flow-sorted leukemic (93% true positive) and normal (93% true negative) cell populations. Four cases with discrepant results had plausible explanations (e.g. partly informative immunophenotype and antigen modulation) that highlight important methodological pitfalls. These findings demonstrate that with sufficient experience, flow cytometry is reliable for minimal residual disease monitoring in B-cell precursor acute lymphoblastic leukemia, although rare cases require supplementary PCR-based monitoring.
Alves, L.P.S.; Almeida, A.T.; Cruz, L.M.; Pedrosa, F.O.; de Souza, E.M.; Chubatsu, L.S.; Müller-Santos, M.; Valdameri, G.
2017-01-01
The conventional method for quantification of polyhydroxyalkanoates based on whole-cell methanolysis and gas chromatography (GC) is laborious and time-consuming. In this work, a method based on flow cytometry of Nile red stained bacterial cells was established to quantify poly-3-hydroxybutyrate (PHB) production by the diazotrophic and plant-associated bacteria, Herbaspirillum seropedicae and Azospirillum brasilense. The method consists of three steps: i) cell permeabilization, ii) Nile red staining, and iii) analysis by flow cytometry. The method was optimized step-by-step and can be carried out in less than 5 min. The final results indicated a high correlation coefficient (R2=0.99) compared to a standard method based on methanolysis and GC. This method was successfully applied to the quantification of PHB in epiphytic bacteria isolated from rice roots. PMID:28099582
In Vivo Myeloperoxidase Imaging and Flow Cytometry Analysis of Intestinal Myeloid Cells.
Hülsdünker, Jan; Zeiser, Robert
2016-01-01
Myeloperoxidase (MPO) imaging is a non-invasive method to detect cells that produce the enzyme MPO that is most abundant in neutrophils, macrophages, and inflammatory monocytes. While lacking specificity for any of these three cell types, MPO imaging can provide guidance for further flow cytometry-based analysis of tissues where these cell types reside. Isolation of leukocytes from the intestinal tract is an error-prone procedure. Here, we describe a protocol for intestinal leukocyte isolation that works reliable in our hands and allows for flow cytometry-based analysis, in particular of neutrophils.
He, Xiaoxiao; Li, Yuhong; He, Dinggen; Wang, Kemin; Shangguan, Jingfang; Shi, Hui
2014-07-01
This paper describes a sensitive and specific determination strategy for Staphylococcus aureus (S. aureus) detection using aptamer recognition and fluorescent silica nanoparticles (FSiNPs) label based dual-color flow cytometry assay (Aptamer/FSiNPs-DCFCM). In the protocol, an aptamer, having high affinity to S. aureus, was first covalently immobilized onto chloropropyl functionalized FSiNPs through a click chemistry approach to generate aptamer-nanoparticles bioconjugates (Aptamer/FSiNPs). Next, S. aureus was incubated with Aptamer/FSiNPs, and then stained with SYBR Green I (a special staining material for the duplex DNA). Upon target binding and nucleic acid staining with SYBR Green I, the S. aureus was determined using two-color flow cytometry. The method took advantage of the specificity of aptamer, signal amplification of FSiNPs label and decreased false positives of two-color flow cytometry assay. It was demonstrated that these Aptamer/FSiNPs could efficiently recognize and fluorescently label target S. aureus. Through multiparameter determination with flow cytometry, this assay allowed for detection of as low as 1.5 x 10(2) and 7.6 x 10(2) cells mL(-1) S. aureus in buffer and spiked milk, respectively, with higher sensitivity than the Aptamer/FITC based flow cytometry.
Nakagawa, Hiroko; Yuno, Tomoji; Itho, Kiichi
2009-03-01
Recently, specific detection method for Bacteria, by flow cytometry method using nucleic acid staining, was developed as a function of automated urine formed elements analyzer for routine urine testing. Here, we performed a basic study on this bacteria analysis method. In addition, we also have a comparison among urine sediment analysis, urine Gram staining and urine quantitative cultivation, the conventional methods performed up to now. As a result, the bacteria analysis with flow cytometry method that uses nucleic acid staining was excellent in reproducibility, and higher sensitivity compared with microscopic urinary sediment analysis. Based on the ROC curve analysis, which settled urine culture method as standard, cut-off level of 120/microL was defined and its sensitivity = 85.7%, specificity = 88.2%. In the analysis of scattergram, accompanied with urine culture method, among 90% of rod positive samples, 80% of dots were appeared in the area of 30 degrees from axis X. In addition, one case even indicated that analysis of bacteria by flow cytometry and scattergram of time series analysis might be helpful to trace the progress of causative bacteria therefore the information supposed to be clinically significant. Reporting bacteria information with nucleic acid staining flow cytometry method is expected to contribute to a rapid diagnostics and treatment of urinary tract infections. Besides, the contribution to screening examination of microbiology and clinical chemistry, will deliver a more efficient solution to urine analysis.
Chen, Si; Weddell, Jared; Gupta, Pavan; Conard, Grace; Parkin, James; Imoukhuede, Princess I
2017-01-01
Nanosensor-based detection of biomarkers can improve medical diagnosis; however, a critical factor in nanosensor development is deciding which biomarker to target, as most diseases present several biomarkers. Biomarker-targeting decisions can be informed via an understanding of biomarker expression. Currently, immunohistochemistry (IHC) is the accepted standard for profiling biomarker expression. While IHC provides a relative mapping of biomarker expression, it does not provide cell-by-cell readouts of biomarker expression or absolute biomarker quantification. Flow cytometry overcomes both these IHC challenges by offering biomarker expression on a cell-by-cell basis, and when combined with calibration standards, providing quantitation of biomarker concentrations: this is known as qFlow cytometry. Here, we outline the key components for applying qFlow cytometry to detect biomarkers within the angiogenic vascular endothelial growth factor receptor family. The key aspects of the qFlow cytometry methodology include: antibody specificity testing, immunofluorescent cell labeling, saturation analysis, fluorescent microsphere calibration, and quantitative analysis of both ensemble and cell-by-cell data. Together, these methods enable high-throughput quantification of biomarker expression.
flowVS: channel-specific variance stabilization in flow cytometry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Azad, Ariful; Rajwa, Bartek; Pothen, Alex
Comparing phenotypes of heterogeneous cell populations from multiple biological conditions is at the heart of scientific discovery based on flow cytometry (FC). When the biological signal is measured by the average expression of a biomarker, standard statistical methods require that variance be approximately stabilized in populations to be compared. Since the mean and variance of a cell population are often correlated in fluorescence-based FC measurements, a preprocessing step is needed to stabilize the within-population variances.
flowVS: channel-specific variance stabilization in flow cytometry
Azad, Ariful; Rajwa, Bartek; Pothen, Alex
2016-07-28
Comparing phenotypes of heterogeneous cell populations from multiple biological conditions is at the heart of scientific discovery based on flow cytometry (FC). When the biological signal is measured by the average expression of a biomarker, standard statistical methods require that variance be approximately stabilized in populations to be compared. Since the mean and variance of a cell population are often correlated in fluorescence-based FC measurements, a preprocessing step is needed to stabilize the within-population variances.
Alternatives to current flow cytometry data analysis for clinical and research studies.
Gondhalekar, Carmen; Rajwa, Bartek; Patsekin, Valery; Ragheb, Kathy; Sturgis, Jennifer; Robinson, J Paul
2018-02-01
Flow cytometry has well-established methods for data analysis based on traditional data collection techniques. These techniques typically involved manual insertion of tube samples into an instrument that, historically, could only measure 1-3 colors. The field has since evolved to incorporate new technologies for faster and highly automated sample preparation and data collection. For example, the use of microwell plates on benchtop instruments is now a standard on virtually every new instrument, and so users can easily accumulate multiple data sets quickly. Further, because the user must carefully define the layout of the plate, this information is already defined when considering the analytical process, expanding the opportunities for automated analysis. Advances in multi-parametric data collection, as demonstrated by the development of hyperspectral flow-cytometry, 20-40 color polychromatic flow cytometry, and mass cytometry (CyTOF), are game-changing. As data and assay complexity increase, so too does the complexity of data analysis. Complex data analysis is already a challenge to traditional flow cytometry software. New methods for reviewing large and complex data sets can provide rapid insight into processes difficult to define without more advanced analytical tools. In settings such as clinical labs where rapid and accurate data analysis is a priority, rapid, efficient and intuitive software is needed. This paper outlines opportunities for analysis of complex data sets using examples of multiplexed bead-based assays, drug screens and cell cycle analysis - any of which could become integrated into the clinical environment. Copyright © 2017. Published by Elsevier Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Srivastava, Nimisha; Singh, Anup K
Microfluidic devices and methods for flow cytometry are described. In described examples, various sample handling and preparation steps may be carried out within a same microfluidic device as flow cytometry steps. A combination of imaging and flow cytometry is described. In some examples, spiral microchannels serve as incubation chambers. Examples of automated sample handling and flow cytometry are described.
Gavin, Carson T; Ali, Sohrab N; Tailly, Thomas; Olvera-Posada, Daniel; Alenezi, Husain; Power, Nicholas E; Hou, Jinqiang; St. Amant, Andre H; Luyt, Leonard G; Wood, Stephen; Wu, Charles; Razvi, Hassan; Leong, Hon S
2016-01-01
Accurate determination of urinary stone composition has significant bearing on understanding pathophysiology, choosing treatment modalities and preventing recurrence. A need exists for improved methods to determine stone composition. Urine of 31 patients with known renal calculi was examined with nanoscale flow cytometry and the calculi collected during surgery subsequently underwent petrographic thin sectioning with polarized and fluorescent microscopy. Fluorescently labeled bisphosphonate probes (Alendronate-fluorescein/Alendronate-Cy5) were developed for nanoscale flow cytometry to enumerate nanocrystals that bound the fluorescent probes. Petrographic sections of stones were also imaged by fluorescent and polarized light microscopy with composition analysis correlated to alendronate +ve nanocrystal counts in corresponding urine samples. Urine samples from patients with Ca2+ and Mg2+ based calculi exhibited the highest alendronate +ve nanocrystal counts, ranging from 100–1000 nm in diameter. This novel urine based assay was in agreement with composition determined by petrographic thin sections with Alendronate probes. In some cases, high alendronate +ve nanocrystal counts indicated a Ca2+ or Mg2+ composition, as confirmed by petrographic analysis, overturning initial spectrophotometric diagnosis of stone composition. The combination of nanoscale flow cytometry and petrographic thin sections offer an alternative means for determining stone composition. Nanoscale flow cytometry of alendronate +ve nanocrystals alone may provide a high-throughput means of evaluating stone burden. PMID:26771074
Ruszczyńska, A; Szteyn, J; Wiszniewska-Laszczych, A
2007-01-01
Producing dairy products which are safe for consumers requires the constant monitoring of the microbiological quality of raw material, the production process itself and the end product. Traditional methods, still a "gold standard", require a specialized laboratory working on recognized and validated methods. Obtaining results is time- and labor-consuming and do not allow rapid evaluation. Hence, there is a need for a rapid, precise method enabling the real-time monitoring of microbiological quality, and flow cytometry serves this function well. It is based on labeling cells suspended in a solution with fluorescent dyes and pumping them into a measurement zone where they are exposed to a precisely focused laser beam. This paper is aimed at presenting the possibilities of applying flow cytometry in the dairy industry.
Evaluation of Leishmania species reactivity in human serologic diagnosis of leishmaniasis.
Silvestre, Ricardo; Santarém, Nuno; Teixeira, Lúcia; Cunha, Joana; Schallig, Henk; Cordeiro-da-Silva, Anabela
2009-08-01
The sensitivities and specificities of IgG-ELISA and IgG flow cytometry based techniques using different Leishmania species were determined using sera collected from 40 cutaneous or visceral leishmaniasis patients. The flow cytometry technique, using promastigote parasite forms, performed better than total soluble extract IgG-ELISA. At the species level, the use of Leishmania amazonensis and Leishmania major as antigens in enzyme linked immunosorbent assay (ELISA) decreased the overall sensitivity. To assess the specificity of these tests, sera from malaria, toxoplasmosis, amoebiasis, schistosomiasis, and leprosy patients were used. We also included sera from Leishmania non-infected endemic individuals. The cutaneous species displayed a decreased specificity in both assays. Although more sensitive, flow cytometry using promastigote parasite forms generally presented lower levels of specificity when compared with total extract of IgG-ELISA. Overall, the results of the study show the potential of IgG flow cytometry for the diagnosis of leishmaniasis. Although highly sensitive, a refinement of the flow cytometry method should be performed to improve the overall specificity.
The role of RhD agglutination for the detection of weak D red cells by anti-D flow cytometry.
Grey, D E; Davies, J I; Connolly, M; Fong, E A; Erber, W N
2005-04-01
Anti-D flow cytometry is an accurate method for quantifying feto-maternal haemorrhage (FMH). However, weak D red cells with <1000 RhD sites are not detectable using this methodology but are immunogenic. As quantitation of RhD sites is not practical, an alternative approach is required to identify those weak D fetal red cells where anti-D flow cytometry is inappropriate. We describe a simple algorithm based on RhD agglutination and flow cytometry peak separation. All weak D (n = 34) gave weak agglutination with RUM-1 on immediate spin (grading =2.5). In Diamed-ID Diaclon ABO/D or ABO/Rh for Newborn cards two subgroups of weak D were observed. In one subgroup, weak agglutination (grading 3) was observed and the red cells were undetectable by flow cytometry. In the second subgroup, agglutination was strong (grading 4) and the red cells were detectable by anti-D flow cytometry. The accuracy of the quantitation was dependent on adequate separation of the weak D and RhD-negative peaks as in seven of 11 samples <1.11% of an expected 2% red cells were detectable. Monitoring RhD agglutination and flow cytometric peak separation are pivotal if anti-D flow cytometry is to be maintained as the primary technique for FMH quantitation in the routine laboratory.
NASA Astrophysics Data System (ADS)
Shah, Amy T.; Cannon, Taylor M.; Higginbotham, Jim N.; Skala, Melissa C.
2016-02-01
Tumor heterogeneity poses challenges for devising optimal treatment regimens for cancer patients. In particular, subpopulations of cells can escape treatment and cause relapse. There is a need for methods to characterize tumor heterogeneity of treatment response. Cell metabolism is altered in cancer (Warburg effect), and cells use the autofluorescent cofactor NADH in numerous metabolic reactions. Previous studies have shown that microscopy measurements of NADH autofluorescence are sensitive to treatment response in breast cancer, and these techniques typically assess hundreds of cells per group. An alternative approach is flow cytometry, which measures fluorescence on a single-cell level and is attractive for characterizing tumor heterogeneity because it achieves high-throughput analysis and cell sorting in millions of cells per group. Current applications for flow cytometry rely on staining with fluorophores. This study characterizes flow cytometry measurements of NADH autofluorescence in breast cancer cells. Preliminary results indicate flow cytometry of NADH is sensitive to cyanide perturbation, which inhibits oxidative phosphorylation, in nonmalignant MCF10A cells. Additionally, flow cytometry is sensitive to higher NADH intensity for HER2-positive SKBr3 cells compared with triple-negative MDA-MB-231 cells. These results agree with previous microscopy studies. Finally, a mixture of SKBr3 and MDA-MB-231 cells were sorted into each cell type using NADH intensity. Sorted cells were cultured, and microscopy validation showed the expected morphology for each cell type. Ultimately, flow cytometry could be applied to characterize tumor heterogeneity based on treatment response and sort cell subpopulations based on metabolic profile. These achievements could enable individualized treatment strategies and improved patient outcomes.
Weigert, Claudia; Steffler, Fabian; Kurz, Tomas; Shellhammer, Thomas H.; Methner, Frank-Jürgen
2009-01-01
The measurement of yeast's intracellular pH (ICP) is a proven method for determining yeast vitality. Vitality describes the condition or health of viable cells as opposed to viability, which defines living versus dead cells. In contrast to fluorescence photometric measurements, which show only average ICP values of a population, flow cytometry allows the presentation of an ICP distribution. By examining six repeated propagations with three separate growth phases (lag, exponential, and stationary), the ICP method previously established for photometry was transferred successfully to flow cytometry by using the pH-dependent fluorescent probe 5,6-carboxyfluorescein. The correlation between the two methods was good (r2 = 0.898, n = 18). With both methods it is possible to track the course of growth phases. Although photometry did not yield significant differences between exponentially and stationary phases (P = 0.433), ICP via flow cytometry did (P = 0.012). Yeast in an exponential phase has a unimodal ICP distribution, reflective of a homogeneous population; however, yeast in a stationary phase displays a broader ICP distribution, and subpopulations could be defined by using the flow cytometry method. In conclusion, flow cytometry yielded specific evidence of the heterogeneity in vitality of a yeast population as measured via ICP. In contrast to photometry, flow cytometry increases information about the yeast population's vitality via a short measurement, which is suitable for routine analysis. PMID:19581482
Choi, Seo Yeon; Yang, Nuri; Jeon, Soo Kyung; Yoon, Tae Hyun
2014-09-01
In this study, we have demonstrated feasibility of a semi-quantitative approach for the estimation of cellular SiO2 nanoparticles (NPs), which is based on the flow cytometry measurements of their normalized side scattering intensity. In order to improve our understanding on the quantitative aspects of cell-nanoparticle interactions, flow cytometry, transmission electron microscopy, and X-ray fluorescence experiments were carefully performed for the HeLa cells exposed to SiO2 NPs with different core diameters, hydrodynamic sizes, and surface charges. Based on the observed relationships among the experimental data, a semi-quantitative cellular SiO2 NPs estimation method from their normalized side scattering and core diameters was proposed, which can be applied for the determination of cellular SiO2 NPs within their size-dependent linear ranges. © 2014 International Society for Advancement of Cytometry.
Xue, Yong; Wilkes, Jon G.; Moskal, Ted J.; Williams, Anna J.; Cooper, Willie M.; Nayak, Rajesh; Rafii, Fatemeh; Buzatu, Dan A.
2016-01-01
Standard methods to detect Escherichia coli contamination in food use the polymerase chain reaction (PCR) and agar culture plates. These methods require multiple incubation steps and take a long time to results. An improved rapid flow-cytometry based detection method was developed, using a fluorescence-labeled oligonucleotide probe specifically binding a16S rRNA sequence. The method positively detected 51 E. coli isolates as well as 4 Shigella species. All 27 non-E. coli strains tested gave negative results. Comparison of the new genetic assay with a total plate count (TPC) assay and agar plate counting indicated similar sensitivity, agreement between cytometry cell and colony counts. This method can detect a small number of E.coli cells in the presence of large numbers of other bacteria. This method can be used for rapid, economical, and stable detection of E. coli and Shigella contamination in the food industry and other contexts. PMID:26913737
Xue, Yong; Wilkes, Jon G; Moskal, Ted J; Williams, Anna J; Cooper, Willie M; Nayak, Rajesh; Rafii, Fatemeh; Buzatu, Dan A
2016-01-01
Standard methods to detect Escherichia coli contamination in food use the polymerase chain reaction (PCR) and agar culture plates. These methods require multiple incubation steps and take a long time to results. An improved rapid flow-cytometry based detection method was developed, using a fluorescence-labeled oligonucleotide probe specifically binding a16S rRNA sequence. The method positively detected 51 E. coli isolates as well as 4 Shigella species. All 27 non-E. coli strains tested gave negative results. Comparison of the new genetic assay with a total plate count (TPC) assay and agar plate counting indicated similar sensitivity, agreement between cytometry cell and colony counts. This method can detect a small number of E.coli cells in the presence of large numbers of other bacteria. This method can be used for rapid, economical, and stable detection of E. coli and Shigella contamination in the food industry and other contexts.
Improved signal recovery for flow cytometry based on ‘spatially modulated emission’
NASA Astrophysics Data System (ADS)
Quint, S.; Wittek, J.; Spang, P.; Levanon, N.; Walther, T.; Baßler, M.
2017-09-01
Recently, the technique of ‘spatially modulated emission’ has been introduced (Baßler et al 2008 US Patent 0080181827A1; Kiesel et al 2009 Appl. Phys. Lett. 94 041107; Kiesel et al 2011 Cytometry A 79A 317-24) improving the signal-to-noise ratio (SNR) for detecting bio-particles in the field of flow cytometry. Based on this concept, we developed two advanced signal processing methods which further enhance the SNR and selectivity for cell detection. The improvements are achieved by adapting digital filtering methods from RADAR technology and mainly address inherent offset elimination, increased signal dynamics and moreover reduction of erroneous detections due to processing artifacts. We present a comprehensive theory on SNR gain and provide experimental results of our concepts.
Chen, Jian; Xue, Chengcheng; Zhao, Yang; Chen, Deyong; Wu, Min-Hsien; Wang, Junbo
2015-01-01
This article reviews recent developments in microfluidic impedance flow cytometry for high-throughput electrical property characterization of single cells. Four major perspectives of microfluidic impedance flow cytometry for single-cell characterization are included in this review: (1) early developments of microfluidic impedance flow cytometry for single-cell electrical property characterization; (2) microfluidic impedance flow cytometry with enhanced sensitivity; (3) microfluidic impedance and optical flow cytometry for single-cell analysis and (4) integrated point of care system based on microfluidic impedance flow cytometry. We examine the advantages and limitations of each technique and discuss future research opportunities from the perspectives of both technical innovation and clinical applications. PMID:25938973
Seidenberg, Ruth; Schuh, Sabine K.; Exadaktylos, Aristomenis K.; Schechter, Clyde B.; Leichtle, Alexander B.; Hautz, Wolf E.
2018-01-01
Objective Patients presenting with suspected urinary tract infection are common in every day emergency practice. Urine flow cytometry has replaced microscopic urine evaluation in many emergency departments, but interpretation of the results remains challenging. The aim of this study was to develop and validate tools that predict urine culture growth out of urine flow cytometry parameter. Methods This retrospective study included all adult patients that presented in a large emergency department between January and July 2017 with a suspected urinary tract infection and had a urine flow cytometry as well as a urine culture obtained. The objective was to identify urine flow cytometry parameters that reliably predict urine culture growth and mixed flora growth. The data set was split into a training (70%) and a validation set (30%) and different decision-making approaches were developed and validated. Results Relevant urine culture growth (respectively mixed flora growth) was found in 40.2% (7.2% respectively) of the 613 patients included. The number of leukocytes and bacteria in flow cytometry were highly associated with urine culture growth, but mixed flora growth could not be sufficiently predicted from the urine flow cytometry parameters. A decision tree, predictive value figures, a nomogram, and a cut-off table to predict urine culture growth from bacteria and leukocyte count were developed, validated and compared. Conclusions Urine flow cytometry parameters are insufficient to predict mixed flora growth. However, the prediction of urine culture growth based on bacteria and leukocyte count is highly accurate and the developed tools should be used as part of the decision-making process of ordering a urine culture or starting an antibiotic therapy if a urogenital infection is suspected. PMID:29474463
Flow Cytometry Techniques in Radiation Biology
1988-06-01
Henidtopoietic stem cells SUMMARY Hematopoietic stem cells ( HSC ) are present in the marrow at a concentration of approximately 2-3 HSC per 1000 nucleated marrow...cells. In the past, only clonogenic assays requiring 8-13 days and ten irradiated recipient rodents were available for assaying HSC . Because of the...importance of HSC in the postirradiation syndrome, we have developed a new rapid method based on flow cytometry not only to assay but also to purify and
Aghaeepour, Nima; Chattopadhyay, Pratip; Chikina, Maria; Dhaene, Tom; Van Gassen, Sofie; Kursa, Miron; Lambrecht, Bart N; Malek, Mehrnoush; McLachlan, G J; Qian, Yu; Qiu, Peng; Saeys, Yvan; Stanton, Rick; Tong, Dong; Vens, Celine; Walkowiak, Sławomir; Wang, Kui; Finak, Greg; Gottardo, Raphael; Mosmann, Tim; Nolan, Garry P; Scheuermann, Richard H; Brinkman, Ryan R
2016-01-01
The Flow Cytometry: Critical Assessment of Population Identification Methods (FlowCAP) challenges were established to compare the performance of computational methods for identifying cell populations in multidimensional flow cytometry data. Here we report the results of FlowCAP-IV where algorithms from seven different research groups predicted the time to progression to AIDS among a cohort of 384 HIV+ subjects, using antigen-stimulated peripheral blood mononuclear cell (PBMC) samples analyzed with a 14-color staining panel. Two approaches (FlowReMi.1 and flowDensity-flowType-RchyOptimyx) provided statistically significant predictive value in the blinded test set. Manual validation of submitted results indicated that unbiased analysis of single cell phenotypes could reveal unexpected cell types that correlated with outcomes of interest in high dimensional flow cytometry datasets. © 2015 International Society for Advancement of Cytometry.
Käser, T; Pasternak, J A; Hamonic, G; Rieder, M; Lai, K; Delgado-Ortega, M; Gerdts, V; Meurens, F
2016-05-01
Chlamydiaceae is a family of intracellular bacteria causing a range of diverse pathological outcomes. The most devastating human diseases are ocular infections with C. trachomatis leading to blindness and genital infections causing pelvic inflammatory disease with long-term sequelae including infertility and chronic pelvic pain. In order to enable the comparison of experiments between laboratories investigating host-chlamydia interactions, the infectious titer has to be determined. Titer determination of chlamydia is most commonly performed via microscopy of host cells infected with a serial dilution of chlamydia. However, other methods including fluorescent ELISpot (Fluorospot) and DNA Chip Scanning Technology have also been proposed to enumerate chlamydia-infected cells. For viruses, flow cytometry has been suggested as a superior alternative to standard titration methods. In this study we compared the use of flow cytometry with microscopy and Fluorospot for the titration of C. suis as a representative of other intracellular bacteria. Titer determination via Fluorospot was unreliable, while titration via microscopy led to a linear read-out range of 16 - 64 dilutions and moderate reproducibility with acceptable standard deviations within and between investigators. In contrast, flow cytometry had a vast linear read-out range of 1,024 dilutions and the lowest standard deviations given a basic training in these methods. In addition, flow cytometry was faster and material costs were lower compared to microscopy. Flow cytometry offers a fast, cheap, precise, and reproducible alternative for the titration of intracellular bacteria like C. suis. © 2016 International Society for Advancement of Cytometry. © 2016 International Society for Advancement of Cytometry.
Novel Quantitative Autophagy Analysis by Organelle Flow Cytometry after Cell Sonication
Degtyarev, Michael; Reichelt, Mike; Lin, Kui
2014-01-01
Autophagy is a dynamic process of bulk degradation of cellular proteins and organelles in lysosomes. Current methods of autophagy measurement include microscopy-based counting of autophagic vacuoles (AVs) in cells. We have developed a novel method to quantitatively analyze individual AVs using flow cytometry. This method, OFACS (organelle flow after cell sonication), takes advantage of efficient cell disruption with a brief sonication, generating cell homogenates with fluorescently labeled AVs that retain their integrity as confirmed with light and electron microscopy analysis. These AVs could be detected directly in the sonicated cell homogenates on a flow cytometer as a distinct population of expected organelle size on a cytometry plot. Treatment of cells with inhibitors of autophagic flux, such as chloroquine or lysosomal protease inhibitors, increased the number of particles in this population under autophagy inducing conditions, while inhibition of autophagy induction with 3-methyladenine or knockdown of ATG proteins prevented this accumulation. This assay can be easily performed in a high-throughput format and opens up previously unexplored avenues for autophagy analysis. PMID:24489953
Flow cytometry: basic principles and applications.
Adan, Aysun; Alizada, Günel; Kiraz, Yağmur; Baran, Yusuf; Nalbant, Ayten
2017-03-01
Flow cytometry is a sophisticated instrument measuring multiple physical characteristics of a single cell such as size and granularity simultaneously as the cell flows in suspension through a measuring device. Its working depends on the light scattering features of the cells under investigation, which may be derived from dyes or monoclonal antibodies targeting either extracellular molecules located on the surface or intracellular molecules inside the cell. This approach makes flow cytometry a powerful tool for detailed analysis of complex populations in a short period of time. This review covers the general principles and selected applications of flow cytometry such as immunophenotyping of peripheral blood cells, analysis of apoptosis and detection of cytokines. Additionally, this report provides a basic understanding of flow cytometry technology essential for all users as well as the methods used to analyze and interpret the data. Moreover, recent progresses in flow cytometry have been discussed in order to give an opinion about the future importance of this technology.
Capture of Fluorescence Decay Times by Flow Cytometry
Naivar, Mark A.; Jenkins, Patrick; Freyer, James P.
2012-01-01
In flow cytometry, the fluorescence decay time of an excitable species has been largely underutilized and is not likely found as a standard parameter on any imaging cytometer, sorting, or analyzing system. Most cytometers lack fluorescence lifetime hardware mainly owing to two central issues. Foremost, research and development with lifetime techniques has lacked proper exploitation of modern laser systems, data acquisition boards, and signal processing techniques. Secondly, a lack of enthusiasm for fluorescence lifetime applications in cells and with bead-based assays has persisted among the greater cytometry community. In this unit, we describe new approaches that address these issues and demonstrate the simplicity of digitally acquiring fluorescence relaxation rates in flow. The unit is divided into protocol and commentary sections in order to provide a most comprehensive discourse on acquiring the fluorescence lifetime with frequency-domain methods. The unit covers (i) standard fluorescence lifetime acquisition (protocol-based) with frequency-modulated laser excitation, (ii) digital frequency-domain cytometry analyses, and (iii) interfacing fluorescence lifetime measurements onto sorting systems. Within the unit is also a discussion on how digital methods are used for aliasing in order to harness higher frequency ranges. Also, a final discussion is provided on heterodyning and processing of waveforms for multi-exponential decay extraction. PMID:25419263
Improving label-free detection of circulating melanoma cells by photoacoustic flow cytometry
NASA Astrophysics Data System (ADS)
Zhou, Huan; Wang, Qiyan; Pang, Kai; Zhou, Quanyu; Yang, Ping; He, Hao; Wei, Xunbin
2018-02-01
Melanoma is a kind of a malignant tumor of melanocytes with the properties of high mortality and high metastasis rate. The circulating melanoma cells with the high content of melanin can be detected by light absorption to diagnose and treat cancer at an early stage. Compared with conventional detection methods such as in vivo flow cytometry (IVFC) based on fluorescence, the in vivo photoacoustic flow cytometry (PAFC) utilizes melanin cells as biomarkers to collect the photoacoustic (PA) signals without toxic fluorescent dyes labeling in a non-invasive way. The information of target tumor cells is helpful for data analysis and cell counting. However, the raw signals in PAFC system contain numerous noises such as environmental noise, device noise and in vivo motion noise. Conventional denoising algorithms such as wavelet denoising (WD) method and means filter (MF) method are based on the local information to extract the data of clinical interest, which remove the subtle feature and leave many noises. To address the above questions, the nonlocal means (NLM) method based on nonlocal data has been proposed to suppress the noise in PA signals. Extensive experiments on in vivo PA signals from the mice with the injection of B16F10 cells in caudal vein have been conducted. All the results indicate that the NLM method has superior noise reduction performance and subtle information reservation.
NASA Astrophysics Data System (ADS)
Jin, Dayong; Piper, James A.; Leif, Robert C.; Yang, Sean; Ferrari, Belinda C.; Yuan, Jingli; Wang, Guilan; Vallarino, Lidia M.; Williams, John W.
2009-03-01
A fundamental problem for rare-event cell analysis is auto-fluorescence from nontarget particles and cells. Time-gated flow cytometry is based on the temporal-domain discrimination of long-lifetime (>1 μs) luminescence-stained cells and can render invisible all nontarget cell and particles. We aim to further evaluate the technique, focusing on detection of ultra-rare-event 5-μm calibration beads in environmental water dirt samples. Europium-labeled 5-μm calibration beads with improved luminescence homogeneity and reduced aggregation were evaluated using the prototype UV LED excited time-gated luminescence (TGL) flow cytometer (FCM). A BD FACSAria flow cytometer was used to sort accurately a very low number of beads (<100 events), which were then spiked into concentrated samples of environmental water. The use of europium-labeled beads permitted the demonstration of specific detection rates of 100%+/-30% and 91%+/-3% with 10 and 100 target beads, respectively, that were mixed with over one million nontarget autofluorescent background particles. Under the same conditions, a conventional FCM was unable to recover rare-event fluorescein isothiocyanate (FITC) calibration beads. Preliminary results on Giardia detection are also reported. We have demonstrated the scientific value of lanthanide-complex biolabels in flow cytometry. This approach may augment the current method that uses multifluorescence-channel flow cytometry gating.
NASA Astrophysics Data System (ADS)
Zordan, M. D.; Leary, James F.
2011-02-01
The clonal isolation of rare cells, especially cancer and stem cells, in a population is important to the development of improved medical treatment. We have demonstrated that the Laser-Enabled Analysis and Processing (LEAP, Cyntellect Inc., San Diego, CA) instrument can be used to efficiently produce single cell clones by photoablative dilution. Additionally, we have also shown that cells present at low frequencies can be cloned by photoablative dilution after they are pre-enriched by flow cytometry based cell sorting. Circulating tumor cells were modeled by spiking isolated peripheral blood cells with cells from the lung carcinoma cell line A549. Flow cytometry based cell sorting was used to perform an enrichment sort of A549 cells directly into a 384 well plate. Photoablative dilution was performed with the LEAPTM instrument to remove any contaminating cells, and clonally isolate 1 side population cell per well. We were able to isolate and grow single clones of side population cells using this method at greater than 90% efficiency. We have developed a 2 step method that is able to perform the clonal isolation of rare cells based on a medically relevant functional phenotype.
A Method for the Interpretation of Flow Cytometry Data Using Genetic Algorithms.
Angeletti, Cesar
2018-01-01
Flow cytometry analysis is the method of choice for the differential diagnosis of hematologic disorders. It is typically performed by a trained hematopathologist through visual examination of bidimensional plots, making the analysis time-consuming and sometimes too subjective. Here, a pilot study applying genetic algorithms to flow cytometry data from normal and acute myeloid leukemia subjects is described. Initially, Flow Cytometry Standard files from 316 normal and 43 acute myeloid leukemia subjects were transformed into multidimensional FITS image metafiles. Training was performed through introduction of FITS metafiles from 4 normal and 4 acute myeloid leukemia in the artificial intelligence system. Two mathematical algorithms termed 018330 and 025886 were generated. When tested against a cohort of 312 normal and 39 acute myeloid leukemia subjects, both algorithms combined showed high discriminatory power with a receiver operating characteristic (ROC) curve of 0.912. The present results suggest that machine learning systems hold a great promise in the interpretation of hematological flow cytometry data.
Isolation of purified oocyst walls and sporocysts from Toxoplasma gondii.
Everson, William V; Ware, Michael W; Dubey, J P; Lindquist, H D Alan
2002-01-01
Toxoplasma gondii oocysts are environmentally resistant and can infect virtually all warm-blooded hosts, including humans and livestock. Little is known about the biochemical basis for this resistance of oocysts, and mechanism for excystation of T. gondii sporozoites. The objective of the present study was to evaluate different methods (mechanical fragmentation, gradients, flow cytometry) to separate and purify T. gondii oocyst walls and sporocysts. Oocyst walls were successfully separated and purified using iodixanol gradients. Sporocysts were successfully separated and purified using iodixanol and Percoll gradients. Purification was also achieved by flow cytometry. Flow cytometry with fluorescence-activated cell sorting (FACS) yielded analytical quantities of oocyst walls and intact sporocysts. Flow cytometry with FACS also proved useful for quantitation of purity obtained following iodixanol gradient fractionation. Methods reported in this paper will be useful for analytical purposes, such as proteomic analysis of components unique to this life cycle stage, development of detection methods, or excystation studies.
In Vivo Flow Cytometry: A Horizon of Opportunities
Tuchin, Valery V.; Tárnok, Attila; Zharov, Vladimir P.
2012-01-01
Flow cytometry has been a fundamental tool of biological discovery for many years. Invasive extraction of cells from a living organism, however, may lead to changes in cell properties and prevents studying cells in their native environment. These problems can be overcome by use of in vivo flow cytometry which provides detection and imaging of circulating normal and abnormal cells directlyin blood or lymph flow. The goal of this mini-review is to provide a brief history, features and challenges of this new generation of flow cytometry methods and instruments. Spectrum of possibilities of in vivo flow cytometry in biological science (e.g., cell metabolism, immune function, or apoptosis) and medical fields (e.g., cancer, infection, cardiovascular disorder) including integrated photoacoustic-photothermal theranostics of circulating abnormal cells are discussed with focus on recent advances of this new platform. PMID:21915991
Rodrigues, Valérie; Baudier, Jean Baptiste; Chantal, Isabelle
2017-09-01
Quantifying cytokines is extremely important in studies of host-pathogen interactions. Multiplex assays are commercially available but only for human and mouse cytokines. Here a method for the simultaneous quantification of five important bovine cytokines IFNγ, IL-4, IL-10, IL-12, and TNFα in cell culture supernatants, using flow cytometry was reported. Functional beads from BD Biosciences expressing specific APC intensity were used. Commercially available antibodies against bovine cytokines were covalently coupled to beads as capture antibodies. Fixed recombinant cytokines were revealed with a second monoclonal antibody coupled with biotin, then revealed with streptavidin-PE. This complex was analyzed using a standard flow cytometer. Experiments were performed to check no cross reactions had occurred. The limits of detection ranged between 0.08 and 0.4 ng/ml depending on the cytokine, and the linearity between the lower and higher limits was remarkable (R 2 > 99.8%). Finally, native cytokines from cell culture supernatants were tested. Results were compared using the standard ELISA test and showed that concentrations of native cytokine in cell culture supernatants were comparable with the two methods, with a wider dynamic range using beads and flow cytometry than with ELISA assays. Bovine IFNγ, IL-4, IL-10, IL-12, and TNFα in culture supernatants can be now simultaneously detected in a single assay, using a standard flow cytometer for both basic and high-throughput analyses. © 2017 International Society for Advancement of Cytometry. © 2017 International Society for Advancement of Cytometry.
Single cell analysis using surface enhanced Raman scattering (SERS) tags
Nolan, John P.; Duggan, Erika; Liu, Er; Condello, Danilo; Dave, Isha; Stoner, Samuel A.
2013-01-01
Fluorescence is a mainstay of bioanalytical methods, offering sensitive and quantitative reporting, often in multiplexed or multiparameter assays. Perhaps the best example of the latter is flow cytometry, where instruments equipped with multiple lasers and detectors allow measurement of 15 or more different fluorophores simultaneously, but increases beyond this number are limited by the relatively broad emission spectra. Surface enhanced Raman scattering (SERS) from metal nanoparticles can produce signal intensities that rival fluorescence, but with narrower spectral features that allow a greater degree of multiplexing. We are developing nanoparticle SERS tags as well as Raman flow cytometers for multiparameter single cell analysis of suspension or adherent cells. SERS tags are based on plasmonically active nanoparticles (gold nanorods) whose plasmon resonance can be tuned to give optimal SERS signals at a desired excitation wavelength. Raman resonant compounds are adsorbed on the nanoparticles to confer a unique spectral fingerprint on each SERS tag, which are then encapsulated in a polymer coating for conjugation to antibodies or other targeting molecules. Raman flow cytometry employs a high resolution spectral flow cytometer capable of measuring the complete SERS spectra, as well as conventional flow cytometry measurements, from thousands of individual cells per minute. Automated spectral unmixing algorithms extract the contributions of each SERS tag from each cell to generate high content, multiparameter single cell population data. SERS-based cytometry is a powerful complement to conventional fluorescence-based cytometry. The narrow spectral features of the SERS signal enables more distinct probes to be measured in a smaller region of the optical spectrum with a single laser and detector, allowing for higher levels of multiplexing and multiparameter analysis. PMID:22498143
Flow cytometric characterization of cerebrospinal fluid cells.
de Graaf, Marieke T; de Jongste, Arjen H C; Kraan, Jaco; Boonstra, Joke G; Sillevis Smitt, Peter A E; Gratama, Jan W
2011-09-01
Flow cytometry facilitates the detection of a large spectrum of cellular characteristics on a per cell basis, determination of absolute cell numbers and detection of rare events with high sensitivity and specificity. White blood cell (WBC) counts in cerebrospinal fluid (CSF) are important for the diagnosis of many neurological disorders. WBC counting and differential can be performed by microscopy, hematology analyzers, or flow cytometry. Flow cytometry of CSF is increasingly being considered as the method of choice in patients suspected of leptomeningeal localization of hematological malignancies. Additionally, in several neuroinflammatory diseases such as multiple sclerosis and paraneoplastic neurological syndromes, flow cytometry is commonly performed to obtain insight into the immunopathogenesis of these diseases. Technically, the low cellularity of CSF samples, combined with the rapidly declining WBC viability, makes CSF flow cytometry challenging. Comparison of flow cytometry with microscopic and molecular techniques shows that each technique has its own advantages and is ideally combined. We expect that increasing the number of flow cytometric parameters that can be simultaneously studied within one sample, will further refine the information on CSF cell subsets in low-cellular CSF samples and enable to define cell populations more accurately. Copyright © 2011 International Clinical Cytometry Society.
Tanev, Stoyan; Sun, Wenbo; Pond, James; Tuchin, Valery V.; Zharov, Vladimir P.
2010-01-01
The formulation of the Finite-Difference Time-Domain (FDTD) approach is presented in the framework of its potential applications to in vivo flow cytometry based on light scattering. The consideration is focused on comparison of light scattering by a single biological cell alone in controlled refractive index matching conditions and by cells labeled by gold nanoparticles. The optical schematics including phase contrast (OPCM) microscopy as a prospective modality for in vivo flow cytometry is also analyzed. The validation of the FDTD approach for the simulation of flow cytometry may open a new avenue in the development of advanced cytometric techniques based on scattering effects from nanoscale targets. PMID:19670359
1993-01-27
Considerable effect was expended in investigating shifts in intercellular calcium of one particular cell line, Jurket, using flow cytometry methods. No...culture. The following analysis were used to characterize the immortalized cell lines: flow cytometry , electron microscopy, two-dimensional protein gel...further characterized by flow cytometry , electron microscopy, two dimensional protein electrophoresis and nuclear run-off assay. Flow cytometric analysis of
Bonar, Micha M.; Tilton, John C.
2017-01-01
Detection of viruses by flow cytometry is complicated by their small size. Here, we characterized the ability of a standard (FACSAria II) and a sub-micron flow cytometer (A50 Micro) to resolve HIV-1 viruses. The A50 was superior at resolving small particles but did not reliably distinguish HIV-1, extracellular vesicles, and laser noise by light scatter properties alone. However, single fluorescent HIV-1 particles could readily be detected by both cytometers. Fluorescent particles were sorted and retained infectivity, permitting further exploration of the functional consequences of HIV-1 heterogeneity. Finally, flow cytometry had a limit of detection of 80 viruses/ml, nearly equal to PCR assays. These studies demonstrate the power of flow cytometry to detect and sort viral particles and provide a critical toolkit to validate methods to label wild-type HIV-1; quantitatively assess integrity and aggregation of viruses and virus-based therapeutics; and efficiently screen drugs inhibiting viral assembly and release. PMID:28235684
Bonar, Michał M; Tilton, John C
2017-05-01
Detection of viruses by flow cytometry is complicated by their small size. Here, we characterized the ability of a standard (FACSAria II) and a sub-micron flow cytometer (A50 Micro) to resolve HIV-1 viruses. The A50 was superior at resolving small particles but did not reliably distinguish HIV-1, extracellular vesicles, and laser noise by light scatter properties alone. However, single fluorescent HIV-1 particles could readily be detected by both cytometers. Fluorescent particles were sorted and retained infectivity, permitting further exploration of the functional consequences of HIV-1 heterogeneity. Finally, flow cytometry had a limit of detection of 80 viruses/ml, nearly equal to PCR assays. These studies demonstrate the power of flow cytometry to detect and sort viral particles and provide a critical toolkit to validate methods to label wild-type HIV-1; quantitatively assess integrity and aggregation of viruses and virus-based therapeutics; and efficiently screen drugs inhibiting viral assembly and release. Copyright © 2017 Elsevier Inc. All rights reserved.
Lay, John C.; Peden, David B.; Alexis, Neil E.
2012-01-01
Background The evaluation of sputum leukocytes by flow cytometry is an opportunity to assess characteristics of cells residing in the central airways, yet it is hampered by certain inherent properties of sputum including mucus and large amounts of contaminating cells and debris. Objective To develop a gating strategy based on specific antibody panels in combination with light scatter properties for flow cytometric evaluation of sputum cells. Methods Healthy and mild asthmatic volunteers underwent sputum induction. Manually selected mucus “plug” material was treated with dithiothrietol, filtered and total leukocytes acquired. Multicolor flow cytometry was performed using specific gating strategies based on light scatter properties, differential expression of CD45 and cell lineage markers to discriminate leukocytes from squamous epithelial cells and debris. Results The combination of forward scatter and CD45 expression reliably segregated sputum leukocytes from contaminating squamous epithelial cells and debris. Overlap of major leukocyte populations (neutrophils, macrophages/monocytes) required the use of specific antibodies (e.g. CD16, CD64, CD14, HLA-DR) that differentiated granulocytes from monocytes and macrophages. These gating strategies allowed identification of small populations of eosinophils, CD11c+ myeloid dendritic cells, B cells and NK cells. Conclusions Multicolor flow cytometry can be successfully applied to sputum samples to identify and characterize leukocyte populations residing on the surfaces of the central airways. PMID:21639708
A Rare Case of Pure Erythroid Sarcoma in a Pediatric Patient: Case Report and Literature Review
Tarín, Fabián; Niveiro, María; Tasso, María; Alda, Olga; Verdú, José J.; De Paz, Francisco; López, Silvia; Del Cañizo, María; Such, Esperanza; Barragán, Eva; Martirena, Fernanda
2017-01-01
We describe an exceptional case of erythroid sarcoma in a pediatric patient as a growing orbital mass with no evidence of morphologic bone marrow involvement, who was finally diagnosed of pure erythroid sarcoma based on histopathology and flow cytometry criteria. We discuss the contribution of standardized eight-color flow cytometry as a rapid and reliable diagnostic method. The use of normal bone marrow databases allowed us to identify small aberrant populations in bone marrow and later confirm the diagnosis in the neoplastic tissue. PMID:29261159
A Rare Case of Pure Erythroid Sarcoma in a Pediatric Patient: Case Report and Literature Review.
Manresa, Pablo; Tarín, Fabián; Niveiro, María; Tasso, María; Alda, Olga; López, Francisco; Sarmiento, Héctor; Verdú, José J; De Paz, Francisco; López, Silvia; Del Cañizo, María; Such, Esperanza; Barragán, Eva; Martirena, Fernanda
2017-12-20
We describe an exceptional case of erythroid sarcoma in a pediatric patient as a growing orbital mass with no evidence of morphologic bone marrow involvement, who was finally diagnosed of pure erythroid sarcoma based on histopathology and flow cytometry criteria. We discuss the contribution of standardized eight-color flow cytometry as a rapid and reliable diagnostic method. The use of normal bone marrow databases allowed us to identify small aberrant populations in bone marrow and later confirm the diagnosis in the neoplastic tissue.
NASA Astrophysics Data System (ADS)
Leif, Robert C.; Spidlen, Josef; Brinkman, Ryan R.
2008-02-01
Introduction: The International Society for Analytical Cytology, ISAC, is developing a new combined flow and image Analytical Cytometry Standard (ACS). This standard needs to serve both the research and clinical communities. The clinical medicine and clinical research communities have a need to exchange information with hospital and other clinical information systems. Methods: 1) Prototype the standard by creating CytometryML and a RAW format for binary data. 2) Join the ISAC Data Standards Task Force. 3) Create essential project documentation. 4) Cooperate with other groups by assisting in the preparation of the DICOM Supplement 122: Specimen Module and Pathology Service-Object Pair Classes. Results: CytometryML has been created and serves as a prototype and source of experience for the following: the Analytical Cytometry Standard (ACS) 1.0, the ACS container, Minimum Information about a Flow Cytometry Experiment (MIFlowCyt), and Requirements for a Data File Standard Format to Describe Flow Cytometry and Related Analytical Cytology Data. These requirements provide a means to judge the appropriateness of design elements and to develop tests for the final ACS. The requirements include providing the information required for understanding and reproducing a cytometry experiment or clinical measurement, and for a single standard for both flow and digital microscopic cytometry. Schemas proposed by other members of the ISAC Data Standards Task Force (e.g, Gating-ML) have been independently validated and have been integrated with CytometryML. The use of netCDF as an element of the ACS container has been proposed by others and a suggested method of its use is proposed.
An active, collaborative approach to learning skills in flow cytometry.
Fuller, Kathryn; Linden, Matthew D; Lee-Pullen, Tracey; Fragall, Clayton; Erber, Wendy N; Röhrig, Kimberley J
2016-06-01
Advances in science education research have the potential to improve the way students learn to perform scientific interpretations and understand science concepts. We developed active, collaborative activities to teach skills in manipulating flow cytometry data using FlowJo software. Undergraduate students were given compensated clinical flow cytometry listmode output (FCS) files and asked to design a gating strategy to diagnose patients with different hematological malignancies on the basis of their immunophenotype. A separate cohort of research trainees was given uncompensated data files on which they performed their own compensation, calculated the antibody staining index, designed a sequential gating strategy, and quantified rare immune cell subsets. Student engagement, confidence, and perceptions of flow cytometry were assessed using a survey. Competency against the learning outcomes was assessed by asking students to undertake tasks that required understanding of flow cytometry dot plot data and gating sequences. The active, collaborative approach allowed students to achieve learning outcomes not previously possible with traditional teaching formats, for example, having students design their own gating strategy, without forgoing essential outcomes such as the interpretation of dot plots. In undergraduate students, favorable perceptions of flow cytometry as a field and as a potential career choice were correlated with student confidence but not the ability to perform flow cytometry data analysis. We demonstrate that this new pedagogical approach to teaching flow cytometry is beneficial for student understanding and interpretation of complex concepts. It should be considered as a useful new method for incorporating complex data analysis tasks such as flow cytometry into curricula. Copyright © 2016 The American Physiological Society.
A novel flow cytometry-based method of analyzing Heinz bodies.
Palasuwan, D; Palasuwan, A; Charoensappakit, A; Noulsri, E
2017-02-01
Heinz bodies are important to diagnosing and managing patients. However, microscopic examination of Heinz bodies has several disadvantages, demonstrating the need for a better method. We explored the potential use of flow cytometry to examine Heinz bodies. Whole-blood samples were collected from patients deficient in G6PD and healthy volunteers. Acetylphenylhydrazine was used to induce formation of Heinz bodies in red blood cells (RBCs). Then, RBCs positive for Heinz bodies were examined using a FACSCanto II cytometer. RBCs treated with acetylphenylhydrazine formed Heinz bodies and emitted a broad spectrum of fluorescence that could be detected by flow cytometry. The maximum emission of fluorescence was observed at 45 min after the incubation with acetylphenylhydrazine. In addition, the fluorescence emitted was stable for at least 72 h. The flow cytometer could detect the RBCs positive for Heinz bodies even if they made up as little as 0.1% of the total RBC population. Furthermore, the percentage and number, respectively, of RBCs positive for Heinz bodies in G6PD-deficient patients and normal donors exhibited a mean ± standard deviation (SD) of 68.9 ± 27.5 vs. 50.9 ± 28.6 and 96 014 ±35 732 cells/μL vs. 74 688 ± 36 514 cells/μL. Heinz bodies induced by acetylphenylhydrazine emit fluorescence, and this fluorescence could be examined using flow cytometry. Our study suggests the potential use of the developed method to investigate the formation of Heinz bodies in clinical samples. © 2016 John Wiley & Sons Ltd.
Bryan, Christopher F; McDonald, Scott B; Baier, Karen A; Luger, Alan M; Aeder, Mark I; Murillo, Daniel; Muruve, Nicolas A; Nelson, Paul W; Shield, Charles F; Warady, Bradley A
2002-01-01
HLA Class I antibody screening can be performed by flow cytometry using a mixture of 30 distinct bead populations each coated with the Class I antigen phenotype derived from different cell lines. In this study we compared the efficacy of Class I antibody screens done by flow cytometry beads with the antihuman globulin (AHG) method for patients awaiting cadaveric renal retransplantation. Class I panel reactive antibody (PRA) screening by flow cytometric beads of 21 regraft serum samples that had all been found to be negative by AHG DTT Class I PRA, revealed that 57.1% (12 of 21) had a flow Class I PRA of > or = 10%. Furthermore, when five regraft sera with an intermediate PRA were screened (mean AHG DTT PRA = 33.2 +/- 13%) the mean flow Class I PRA almost doubled (mean flow PRA = 72.4 +/- 10.2%) (p < 0.01). When active UNOS waiting list regraft candidates, after several months of screening the Class I PRA by flow beads, were divided into the three PRA categories based on their peak flow Class I PRA value (0-20%, 21-79% and > or = 80%), the incidence of a positive flow cross-match was 0%, 72% and 85% and the incidence of retransplantation was 60%, 22% and 10%, in each of these groups, respectively. These data provided our histocompatibility laboratory with the rationale to stop performing the AHG PRA and perform only the flow Class I PRA method for regraft candidates.
Flow Cytometry and Solid Organ Transplantation: A Perfect Match
Maguire, Orla; Tario, Joseph D.; Shanahan, Thomas C.; Wallace, Paul K.; Minderman, Hans
2015-01-01
In the field of transplantation, flow cytometry serves a well-established role in pre-transplant crossmatching and monitoring immune reconstitution following hematopoietic stem cell transplantation. The capabilities of flow cytometers have continuously expanded and this combined with more detailed knowledge of the constituents of the immune system, their function and interaction and newly developed reagents to study these parameters have led to additional utility of flow cytometry-based analyses, particularly in the post-transplant setting. This review discusses the impact of flow cytometry on managing alloantigen reactions, monitoring opportunistic infections and graft rejection and gauging immunosuppression in the context of solid organ transplantation. PMID:25296232
Sgier, Linn; Freimann, Remo; Zupanic, Anze; Kroll, Alexandra
2016-01-01
Biofilms serve essential ecosystem functions and are used in different technical applications. Studies from stream ecology and waste-water treatment have shown that biofilm functionality depends to a great extent on community structure. Here we present a fast and easy-to-use method for individual cell-based analysis of stream biofilms, based on stain-free flow cytometry and visualization of the high-dimensional data by viSNE. The method allows the combined assessment of community structure, decay of phototrophic organisms and presence of abiotic particles. In laboratory experiments, it allows quantification of cellular decay and detection of survival of larger cells after temperature stress, while in the field it enables detection of community structure changes that correlate with known environmental drivers (flow conditions, dissolved organic carbon, calcium) and detection of microplastic contamination. The method can potentially be applied to other biofilm types, for example, for inferring community structure for environmental and industrial research and monitoring. PMID:27188265
NASA Astrophysics Data System (ADS)
Leif, Robert C.; Leif, Stephanie H.
2016-04-01
Introduction: The International Society for Advancement of Cytometry (ISAC) has created a standard for the Minimum Information about a Flow Cytometry Experiment (MIFlowCyt 1.0). CytometryML will serve as a common metadata standard for flow and image cytometry (digital microscopy). Methods: The MIFlowCyt data-types were created, as is the rest of CytometryML, in the XML Schema Definition Language (XSD1.1). The datatypes are primarily based on the Flow Cytometry and the Digital Imaging and Communication (DICOM) standards. A small section of the code was formatted with standard HTML formatting elements (p, h1, h2, etc.). Results:1) The part of MIFlowCyt that describes the Experimental Overview including the specimen and substantial parts of several other major elements has been implemented as CytometryML XML schemas (www.cytometryml.org). 2) The feasibility of using MIFlowCyt to provide the combination of an overview, table of contents, and/or an index of a scientific paper or a report has been demonstrated. Previously, a sample electronic publication, EPUB, was created that could contain both MIFlowCyt metadata as well as the binary data. Conclusions: The use of CytometryML technology together with XHTML5 and CSS permits the metadata to be directly formatted and together with the binary data to be stored in an EPUB container. This will facilitate: formatting, data- mining, presentation, data verification, and inclusion in structured research, clinical, and regulatory documents, as well as demonstrate a publication's adherence to the MIFlowCyt standard, promote interoperability and should also result in the textual and numeric data being published using web technology without any change in composition.
Flow cytometry for the assessment of animal sperm integrity and functionality: state of the art
Hossain, Md. Sharoare; Johannisson, Anders; Wallgren, Margareta; Nagy, Szabolcs; Siqueira, Amanda Pimenta; Rodriguez-Martinez, Heriberto
2011-01-01
Flow cytometry is now a recognized methodology within animal spermatology, and has moved from being a research tool to become routine in the assessment of animal semen destined to breeding. The availability of ‘bench-top' flow cytometers and of newer and versatile markers for cell structure and function had allowed the instrumentation to measure more sperm parameters, from viability to reactiveness when exposed to exogenous stimuli, and to increase our capabilities to sort spermatozoa for potential fertilizing capacity, or chromosomal sex. The present review summarizes the state of the art regarding flow cytometry applied to animal andrology, albeit keeping an open comparative intent. It critically evaluates the present and future capabilities of flow cytometry for the diagnostics of potential fertility and for the development of current reproductive technologies such as sperm freezing, sperm selection and sperm sorting. The flow cytometry methods will probably further revolutionize our understanding of the sperm physiology and their functionality, and will undoubtedly extend its application in isolating many uncharacterized features of spermatozoa. However, continuous follow-up of the methods is a necessity owing to technical developments and the complexity of mapping spermatozoa. PMID:21478895
RNA Flow Cytometry Using the Branched DNA Technique.
Soh, Kah Teong; Wallace, Paul K
2018-01-01
The systematic modulation of mRNA and proteins governs the complicated and intermingled biological functions of our cells. Traditionally, transcriptomic technologies such as DNA microarray and RNA-Seq have been used to identify, characterize, and profile gene expression data. These are, however, considered bulk methods as they are unable to measure gene expression at the single-cell level, unless the cells are pre-sorted. Branched DNA is a flow cytometry-based detection platform that has been developed recently to measure mRNA at the single-cell level. Originally adapted from microscopy, the current system has been modified to achieve compatibility with the detection of surface and intracellular antigens using monoclonal antibodies conjugated to fluorochromes, thus permitting simultaneous detection of mRNAs and proteins. The Branched DNA method offers a variety of advantages when compared to traditional or standard methods used for the quantification of mRNA, such as (a) the detection of specific mRNA on a per cell basis, (b) an alternate detection tool when the measurement of a protein is technically infeasible (i.e., no quality antibody exists) or the epitope is not assessable, and (c) correlate the analysis of mRNA with protein. Compared to earlier attempts at measuring nucleic acid by flow cytometry, the hybridization temperature applied in the Branched DNA assay is much lower, thus preserving the integrity of cellular structures for further characterization. It also has greatly increased specificity and sensitivity. Here, we provide detailed instruction for performing the Branched DNA method using it in a model system to correlate the expression of CD8 mRNA and CD8 protein by flow cytometry.
Progress on an implementation of MIFlowCyt in XML
NASA Astrophysics Data System (ADS)
Leif, Robert C.; Leif, Stephanie H.
2015-03-01
Introduction: The International Society for Advancement of Cytometry (ISAC) Data Standards Task Force (DSTF) has created a standard for the Minimum Information about a Flow Cytometry Experiment (MIFlowCyt 1.0). The CytometryML schemas, are based in part upon the Flow Cytometry Standard and Digital Imaging and Communication (DICOM) standards. CytometryML has and will be extended and adapted to include MIFlowCyt, as well as to serve as a common standard for flow and image cytometry (digital microscopy). Methods: The MIFlowCyt data-types were created, as is the rest of CytometryML, in the XML Schema Definition Language (XSD1.1). Individual major elements of the MIFlowCyt schema were translated into XML and filled with reasonable data. A small section of the code was formatted with HTML formatting elements. Results: The differences in the amount of detail to be recorded for 1) users of standard techniques including data analysts and 2) others, such as method and device creators, laboratory and other managers, engineers, and regulatory specialists required that separate data-types be created to describe the instrument configuration and components. A very substantial part of the MIFlowCyt element that describes the Experimental Overview part of the MIFlowCyt and substantial parts of several other major elements have been developed. Conclusions: The future use of structured XML tags and web technology should facilitate searching of experimental information, its presentation, and inclusion in structured research, clinical, and regulatory documents, as well as demonstrate in publications adherence to the MIFlowCyt standard. The use of CytometryML together with XML technology should also result in the textual and numeric data being published using web technology without any change in composition. Preliminary testing indicates that CytometryML XML pages can be directly formatted with the combination of HTML and CSS.
CytometryML with DICOM and FCS
NASA Astrophysics Data System (ADS)
Leif, Robert C.
2018-02-01
Abstract: Flow Cytometry Standard, FCS, and Digital Imaging and Communications in Medicine standard, DICOM, are based on extensive, superb domain knowledge, However, they are isolated systems, do not take advantage of data structures, require special programs to read and write the data, lack the capability to interoperate or work with other standards and FCS lacks many of the datatypes necessary for clinical laboratory data. The large overlap between imaging and flow cytometry provides strong evidence that both modalities should be covered by the same standard. Method: The XML Schema Definition Language, XSD 1.1 was used to translate FCS and/or DICOM objects. A MIFlowCyt file was tested with published values. Results: Previously, a significant part of an XML standard based upon a combination of FCS and DICOM has been implemented and validated with MIFlowCyt data. Strongly typed translations of FCS keywords have been constructed in XML. These keywords contain links to their DICOM and FCS equivalents.
CytometryML: a markup language for analytical cytology
NASA Astrophysics Data System (ADS)
Leif, Robert C.; Leif, Stephanie H.; Leif, Suzanne B.
2003-06-01
Cytometry Markup Language, CytometryML, is a proposed new analytical cytology data standard. CytometryML is a set of XML schemas for encoding both flow cytometry and digital microscopy text based data types. CytometryML schemas reference both DICOM (Digital Imaging and Communications in Medicine) codes and FCS keywords. These schemas provide representations for the keywords in FCS 3.0 and will soon include DICOM microscopic image data. Flow Cytometry Standard (FCS) list-mode has been mapped to the DICOM Waveform Information Object. A preliminary version of a list mode binary data type, which does not presently exist in DICOM, has been designed. This binary type is required to enhance the storage and transmission of flow cytometry and digital microscopy data. Index files based on Waveform indices will be used to rapidly locate the cells present in individual subsets. DICOM has the advantage of employing standard file types, TIF and JPEG, for Digital Microscopy. Using an XML schema based representation means that standard commercial software packages such as Excel and MathCad can be used to analyze, display, and store analytical cytometry data. Furthermore, by providing one standard for both DICOM data and analytical cytology data, it eliminates the need to create and maintain special purpose interfaces for analytical cytology data thereby integrating the data into the larger DICOM and other clinical communities. A draft version of CytometryML is available at www.newportinstruments.com.
Optofluidic time-stretch microscopy: recent advances
NASA Astrophysics Data System (ADS)
Lei, Cheng; Nitta, Nao; Ozeki, Yasuyuki; Goda, Keisuke
2018-06-01
Flow cytometry is an indispensable method for valuable applications in numerous fields such as immunology, pathology, pharmacology, molecular biology, and marine biology. Optofluidic time-stretch microscopy is superior to conventional flow cytometry methods for its capability to acquire high-quality images of single cells at a high-throughput exceeding 10,000 cells per second. This makes it possible to extract copious information from cellular images for accurate cell detection and analysis with the assistance of machine learning. Optofluidic time-stretch microscopy has proven its effectivity in various applications, including microalga-based biofuel production, evaluation of thrombotic disorders, as well as drug screening and discovery. In this review, we discuss the principles and recent advances of optofluidic time-stretch microscopy.
Optofluidic time-stretch microscopy: recent advances
NASA Astrophysics Data System (ADS)
Lei, Cheng; Nitta, Nao; Ozeki, Yasuyuki; Goda, Keisuke
2018-04-01
Flow cytometry is an indispensable method for valuable applications in numerous fields such as immunology, pathology, pharmacology, molecular biology, and marine biology. Optofluidic time-stretch microscopy is superior to conventional flow cytometry methods for its capability to acquire high-quality images of single cells at a high-throughput exceeding 10,000 cells per second. This makes it possible to extract copious information from cellular images for accurate cell detection and analysis with the assistance of machine learning. Optofluidic time-stretch microscopy has proven its effectivity in various applications, including microalga-based biofuel production, evaluation of thrombotic disorders, as well as drug screening and discovery. In this review, we discuss the principles and recent advances of optofluidic time-stretch microscopy.
Methodology and application of flow cytometry for investigation of human malaria parasites.
Grimberg, Brian T
2011-03-31
Historically, examinations of the inhibition of malaria parasite growth/invasion, whether using drugs or antibodies, have relied on the use of microscopy or radioactive hypoxanthine uptake. These are considered gold standards for measuring the effectiveness of antimalarial treatments, however, these methods have well known shortcomings. With the advent of flow cytometry coupled with the use of fluorescent DNA stains allowed for increased speed, reproducibility, and qualitative estimates of the effectiveness of antibodies and drugs to limit malaria parasite growth which addresses the challenges of traditional techniques. Because materials and machines available to research facilities are so varied, different methods have been developed to investigate malaria parasites by flow cytometry. This review is intended to serve as a reference guide for advanced users and importantly, as a primer for new users, to support expanded use and improvements to malaria flow cytometry, particularly in endemic countries. Copyright © 2011 Elsevier B.V. All rights reserved.
2002-01-01
the TM- FKHRL1 construct exhibited exclusive nuclear localization Cell Cycle Analysis by Flow Cytometry of the HA-tagged mutant under any experimental...distribution as measured by flow cytometry (Figure 8A). ALS AND METHODS. Consistent with its antiapoptotic effect, these results, addi- tion of TGFI3... flow cytometry . Under these conditions more than 95% of selected cells expressed GFP at the time of experiments. Immunoblot Analysis. Cells were
Soh, Kah Teong; Tario, Joseph D.; Wallace, Paul K.
2018-01-01
Synopsis Plasma cell dyscrasia (PCD) is a heterogeneous disease which has seen a tremendous change in outcomes due to improved therapies. Over the last few decades, multiparametric flow cytometry has played an important role in the detection and monitoring of PCDs. Flow cytometry is a high sensitivity assay for early detection of minimal residual disease (MRD) that correlates well with progression-free survival and overall survival. Before flow cytometry can be effectively implemented in the clinical setting sample preparation, panel configuration, analysis, and gating strategies must be optimized to ensure accurate results. Current consensus methods and reporting guidelines for MRD testing are discussed. PMID:29128071
Tanev, Stoyan; Sun, Wenbo; Pond, James; Tuchin, Valery V; Zharov, Vladimir P
2009-09-01
The formulation of the finite-difference time-domain (FDTD) approach is presented in the framework of its potential applications to in-vivo flow cytometry based on light scattering. The consideration is focused on comparison of light scattering by a single biological cell alone in controlled refractive-index matching conditions and by cells labeled by gold nanoparticles. The optical schematics including phase contrast (OPCM) microscopy as a prospective modality for in-vivo flow cytometry is also analyzed. The validation of the FDTD approach for the simulation of flow cytometry may open up a new avenue in the development of advanced cytometric techniques based on scattering effects from nanoscale targets. 2009 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vasdekis, Andreas E.; Stephanopoulos, Gregory
The sampling and manipulation of cells down to the individual has been of substantial interest since the very beginning of Life Sciences. Herein, our objective is to highlight the most recent developments in single cell manipulation, as well as pioneering ones. First, flow-through methods will be discussed, namely methods in which the single cells flow continuously in an ordered manner during their analysis. This section will be followed by confinement techniques that enable cell isolation and confinement in one, two- or three-dimensions. Flow cytometry and droplet microfluidics are the two most common methods of flow-through analysis. While both are high-throughputmore » techniques, their difference lays in the fact that the droplet encapsulated cells experience a restricted and personal microenvironment, while in flow cytometry cells experience similar nutrient and stimuli initial concentrations. These methods are rather well established; however, they recently enabled immense strides in single cell phenotypic analysis, namely the identification and analysis of metabolically distinct individuals from an isogenic population using both droplet microfluidics and flow cytometry.« less
Benítez, Francisco Moreno; Camacho, Antonio Letrán; Del Cuvillo Bernal, Alfonso; de Medina, Pedro Lobatón Sánchez; Cózar, Francisco J García; Romeu, Ma Luisa Espinazo
2013-07-10
Background: There is an increase in the incidence of pollen related allergy, thus information on pollen schedules would be a great asset for physicians to improve the clinical care of patients. Like cypress pollen sensitization shows a high prevalence among the causes of allergic rhinitis, and therefore it is of interest to use it like a model of study, distinguishing cypress pollen, pollen count and allergenic load level. In this work, we use a flow cytometry based technique to obtain both Cupressus arizonica pollen count and allergenic load, using specific rabbit polyclonal antibody Cup a1 and its comparison with optical microscopy technique measurement. Methods: Airborne samples were collected from Burkard Spore-Trap and Burkard Cyclone Cupressus arizonica pollen was studied using specific rabbit polyclonal antibody Cup a1, labelled with AlexaFluor ® 488 or 750 and analysed by Flow Cytometry in both an EPICS XL and Cyan ADP cytometers (Beckman Coulter ® ). Optical microscopy study was realized with a Leica optical microscope. Bland & Altman was used to determine agreement between both techniques measured. Results: We can identify three different populations based on rabbit polyclonal antibody Cup a1 staining. The main region (44.5%) had 97.3% recognition, a second region (25%) with 28% and a third region (30.5%) with 68% respectively. Immunofluorescence and confocal microscopy showed that main region corresponds to whole pollen grains, the second region are pollen without exine and the third region is constituted by smaller particles with allergenic properties. Pollen schedule shows a higher correlation measured by optical microscopy and flow cytometry in the pollen count with a p-value: 0.0008E -2 and 0.0002 with regard to smaller particles, so the Bland & Altman measurement showed a good correlation between them, p-value: 0,0003. Conclusion: Determination of pollen count and allergenic load by flow cytometry represents an important tool in the determination of airborne respiratory allergens. We showed that not only whole pollen but also smaller particles could induce allergic sensitization. This is the first study where flow cytometry is used for calculating pollen counts and allergenic load. © 2013 Clinical Cytometry Society. Copyright © 2013 Clinical Cytometry Society.
Mesenchymal Stem Cells for Vascular Target Discovery in Breast Cancer-Associated Angiogenesis
2004-09-01
Matrigel plug and sorted by flow cytometry . Sorting of these retrieved cells based on co-expression of the GFP marker and cell- surface endothelial...express the green fluorescent protein (GFP) and clonal MSC populations can be isolated and phenotypically and genotypically analyzed by flow cytometry ...monoclonal populations of these GFP+ murine MSCs and conducted flow cytometry analysis to determine their phenotype. Specifically, we determined if
Zhou, Haiying; Gunsten, Sean P.; Zhegalova, Natalia G.; Bloch, Sharon; Achilefu, Samuel; Holley, J. Christopher; Schweppe, Daniel; Akers, Walter; Brody, Steven L.; Eades, William; Berezin, Mikhail Y.
2016-01-01
In vivo optical imaging with near-infrared (NIR) probes is an established method of diagnostics in preclinical and clinical studies. However, the specificities of these probes are difficult to validate ex vivo due to the lack of NIR flow cytometry. To address this limitation, we modified a flow cytometer to include an additional NIR channel using a 752 nm laser line. The flow cytometry system was tested using NIR microspheres and cell lines labeled with a combination of visible range and NIR fluorescent dyes. The approach was verified in vivo in mice evaluated for immune response in lungs after intratracheal delivery of the NIR contrast agent. Flow cytometry of cells obtained from the lung bronchoalveolar lavage demonstrated that the NIR dye was taken up by pulmonary macrophages as early as four-hours post-injection. This combination of optical imaging with NIR flow cytometry extends the capability of imaging and enables complementation of in vivo imaging with cell-specific studies. PMID:25808737
van der Gaast—de Jongh, Christa E.; Diavatopoulos, Dimitri A.; de Jonge, Marien I.
2017-01-01
The respiratory pathogen Streptococcus pneumoniae is a major cause of diseases such as otitis media, pneumonia, sepsis and meningitis. The first step towards infection is colonization of the nasopharynx. Recently, it was shown that agglutinating antibodies play an important role in the prevention of mucosal colonization with S. pneumoniae. Here, we present a novel method to quantify antibody-dependent pneumococcal agglutination in a high-throughput manner using flow cytometry. We found that the concentration of agglutinating antibodies against pneumococcal capsule are directly correlated with changes in the size and complexity of bacterial aggregates, as measured by flow cytometry and confirmed by light microscopy. Using the increase in size, we determined the agglutination index. The cutoff value was set by measuring a series of non-agglutinating antibodies. With this method, we show that not only anti-polysaccharide capsule antibodies are able to induce agglutination but that also anti-PspA protein antibodies have agglutinating capabilities. In conclusion, we have described and validated a novel method to quantify pneumococcal agglutination, which can be used to screen sera from murine or human vaccination studies, in a high-throughput manner. PMID:28288168
CytometryML, an XML format based on DICOM and FCS for analytical cytology data.
Leif, Robert C; Leif, Suzanne B; Leif, Stephanie H
2003-07-01
Flow Cytometry Standard (FCS) was initially created to standardize the software researchers use to analyze, transmit, and store data produced by flow cytometers and sorters. Because of the clinical utility of flow cytometry, it is necessary to have a standard consistent with the requirements of medical regulatory agencies. We extended the existing mapping of FCS to the Digital Imaging and Communications in Medicine (DICOM) standard to include list-mode data produced by flow cytometry, laser scanning cytometry, and microscopic image cytometry. FCS list-mode was mapped to the DICOM Waveform Information Object. We created a collection of Extensible Markup Language (XML) schemas to express the DICOM analytical cytologic text-based data types except for large binary objects. We also developed a cytometry markup language, CytometryML, in an open environment subject to continuous peer review. The feasibility of expressing the data contained in FCS, including list-mode in DICOM, was demonstrated; and a preliminary mapping for list-mode data in the form of XML schemas and documents was completed. DICOM permitted the creation of indices that can be used to rapidly locate in a list-mode file the cells that are members of a subset. DICOM and its coding schemes for other medical standards can be represented by XML schemas, which can be combined with other relevant XML applications, such as Mathematical Markup Language (MathML). The use of XML format based on DICOM for analytical cytology met most of the previously specified requirements and appears capable of meeting the others; therefore, the present FCS should be retired and replaced by an open, XML-based, standard CytometryML. Copyright 2003 Wiley-Liss, Inc.
Finak, Greg; Frelinger, Jacob; Jiang, Wenxin; Newell, Evan W.; Ramey, John; Davis, Mark M.; Kalams, Spyros A.; De Rosa, Stephen C.; Gottardo, Raphael
2014-01-01
Flow cytometry is used increasingly in clinical research for cancer, immunology and vaccines. Technological advances in cytometry instrumentation are increasing the size and dimensionality of data sets, posing a challenge for traditional data management and analysis. Automated analysis methods, despite a general consensus of their importance to the future of the field, have been slow to gain widespread adoption. Here we present OpenCyto, a new BioConductor infrastructure and data analysis framework designed to lower the barrier of entry to automated flow data analysis algorithms by addressing key areas that we believe have held back wider adoption of automated approaches. OpenCyto supports end-to-end data analysis that is robust and reproducible while generating results that are easy to interpret. We have improved the existing, widely used core BioConductor flow cytometry infrastructure by allowing analysis to scale in a memory efficient manner to the large flow data sets that arise in clinical trials, and integrating domain-specific knowledge as part of the pipeline through the hierarchical relationships among cell populations. Pipelines are defined through a text-based csv file, limiting the need to write data-specific code, and are data agnostic to simplify repetitive analysis for core facilities. We demonstrate how to analyze two large cytometry data sets: an intracellular cytokine staining (ICS) data set from a published HIV vaccine trial focused on detecting rare, antigen-specific T-cell populations, where we identify a new subset of CD8 T-cells with a vaccine-regimen specific response that could not be identified through manual analysis, and a CyTOF T-cell phenotyping data set where a large staining panel and many cell populations are a challenge for traditional analysis. The substantial improvements to the core BioConductor flow cytometry packages give OpenCyto the potential for wide adoption. It can rapidly leverage new developments in computational cytometry and facilitate reproducible analysis in a unified environment. PMID:25167361
Finak, Greg; Frelinger, Jacob; Jiang, Wenxin; Newell, Evan W; Ramey, John; Davis, Mark M; Kalams, Spyros A; De Rosa, Stephen C; Gottardo, Raphael
2014-08-01
Flow cytometry is used increasingly in clinical research for cancer, immunology and vaccines. Technological advances in cytometry instrumentation are increasing the size and dimensionality of data sets, posing a challenge for traditional data management and analysis. Automated analysis methods, despite a general consensus of their importance to the future of the field, have been slow to gain widespread adoption. Here we present OpenCyto, a new BioConductor infrastructure and data analysis framework designed to lower the barrier of entry to automated flow data analysis algorithms by addressing key areas that we believe have held back wider adoption of automated approaches. OpenCyto supports end-to-end data analysis that is robust and reproducible while generating results that are easy to interpret. We have improved the existing, widely used core BioConductor flow cytometry infrastructure by allowing analysis to scale in a memory efficient manner to the large flow data sets that arise in clinical trials, and integrating domain-specific knowledge as part of the pipeline through the hierarchical relationships among cell populations. Pipelines are defined through a text-based csv file, limiting the need to write data-specific code, and are data agnostic to simplify repetitive analysis for core facilities. We demonstrate how to analyze two large cytometry data sets: an intracellular cytokine staining (ICS) data set from a published HIV vaccine trial focused on detecting rare, antigen-specific T-cell populations, where we identify a new subset of CD8 T-cells with a vaccine-regimen specific response that could not be identified through manual analysis, and a CyTOF T-cell phenotyping data set where a large staining panel and many cell populations are a challenge for traditional analysis. The substantial improvements to the core BioConductor flow cytometry packages give OpenCyto the potential for wide adoption. It can rapidly leverage new developments in computational cytometry and facilitate reproducible analysis in a unified environment.
Spear, Timothy T; Nishimura, Michael I; Simms, Patricia E
2017-08-01
Advancement in flow cytometry reagents and instrumentation has allowed for simultaneous analysis of large numbers of lineage/functional immune cell markers. Highly complex datasets generated by polychromatic flow cytometry require proper analytical software to answer investigators' questions. A problem among many investigators and flow cytometry Shared Resource Laboratories (SRLs), including our own, is a lack of access to a flow cytometry-knowledgeable bioinformatics team, making it difficult to learn and choose appropriate analysis tool(s). Here, we comparatively assess various multidimensional flow cytometry software packages for their ability to answer a specific biologic question and provide graphical representation output suitable for publication, as well as their ease of use and cost. We assessed polyfunctional potential of TCR-transduced T cells, serving as a model evaluation, using multidimensional flow cytometry to analyze 6 intracellular cytokines and degranulation on a per-cell basis. Analysis of 7 parameters resulted in 128 possible combinations of positivity/negativity, far too complex for basic flow cytometry software to analyze fully. Various software packages were used, analysis methods used in each described, and representative output displayed. Of the tools investigated, automated classification of cellular expression by nonlinear stochastic embedding (ACCENSE) and coupled analysis in Pestle/simplified presentation of incredibly complex evaluations (SPICE) provided the most user-friendly manipulations and readable output, evaluating effects of altered antigen-specific stimulation on T cell polyfunctionality. This detailed approach may serve as a model for other investigators/SRLs in selecting the most appropriate software to analyze complex flow cytometry datasets. Further development and awareness of available tools will help guide proper data analysis to answer difficult biologic questions arising from incredibly complex datasets. © Society for Leukocyte Biology.
Fundamentals of flow cytometry.
Jaroszeski, M J; Radcliff, G
1999-02-01
Flow cytometers are instruments that are used primarily to measure the physical and biochemical characteristics of biological particles. This technology is used to perform measurements on whole cells as well as prepared cellular constituents, such as nuclei and organelles. Flow cytometers are investigative tools for a broad range of scientific disciplines because they make measurements on thousands of individual cells/particles in a matter of seconds. This is a unique advantage relative to other detection instruments that provide bulk particle measurements. Flow cytometry is a complex and highly technical field; therefore, a basic understanding of the technology is essential for all users. The purpose of this article is to provide fundamental information about the instrumentation used for flow cytometry as well as the methods used to analyze and interpret data. This information will provide a foundation to use flow cytometry effectively as a research tool.
Arrigucci, Riccardo; Bushkin, Yuri; Radford, Felix; Lakehal, Karim; Vir, Pooja; Pine, Richard; Martin, December; Sugarman, Jeffrey; Zhao, Yanlin; Yap, George S; Lardizabal, Alfred A; Tyagi, Sanjay; Gennaro, Maria Laura
2017-01-01
We describe a flow-cytometry-based protocol for intracellular mRNA measurements in nonadherent mammalian cells using fluorescence in situ hybridization (FISH) probes. The method, which we call FISH-Flow, allows for high-throughput multiparametric measurements of gene expression, a task that was not feasible with earlier, microscopy-based approaches. The FISH-Flow protocol involves cell fixation, permeabilization and hybridization with a set of fluorescently labeled oligonucleotide probes. In this protocol, surface and intracellular protein markers can also be stained with fluorescently labeled antibodies for simultaneous protein and mRNA measurement. Moreover, a semiautomated, single-tube version of the protocol can be performed with a commercially available cell-wash device that reduces cell loss, operator time and interoperator variability. It takes ~30 h to perform this protocol. An example of FISH-Flow measurements of cytokine mRNA induction by ex vivo stimulation of primed T cells with specific antigens is described. PMID:28518171
Qian, Yu; Wei, Chungwen; Lee, F. Eun-Hyung; Campbell, John; Halliley, Jessica; Lee, Jamie A.; Cai, Jennifer; Kong, Megan; Sadat, Eva; Thomson, Elizabeth; Dunn, Patrick; Seegmiller, Adam C.; Karandikar, Nitin J.; Tipton, Chris; Mosmann, Tim; Sanz, Iñaki; Scheuermann, Richard H.
2011-01-01
Background Advances in multi-parameter flow cytometry (FCM) now allow for the independent detection of larger numbers of fluorochromes on individual cells, generating data with increasingly higher dimensionality. The increased complexity of these data has made it difficult to identify cell populations from high-dimensional FCM data using traditional manual gating strategies based on single-color or two-color displays. Methods To address this challenge, we developed a novel program, FLOCK (FLOw Clustering without K), that uses a density-based clustering approach to algorithmically identify biologically relevant cell populations from multiple samples in an unbiased fashion, thereby eliminating operator-dependent variability. Results FLOCK was used to objectively identify seventeen distinct B cell subsets in a human peripheral blood sample and to identify and quantify novel plasmablast subsets responding transiently to tetanus and other vaccinations in peripheral blood. FLOCK has been implemented in the publically available Immunology Database and Analysis Portal – ImmPort (http://www.immport.org) for open use by the immunology research community. Conclusions FLOCK is able to identify cell subsets in experiments that use multi-parameter flow cytometry through an objective, automated computational approach. The use of algorithms like FLOCK for FCM data analysis obviates the need for subjective and labor intensive manual gating to identify and quantify cell subsets. Novel populations identified by these computational approaches can serve as hypotheses for further experimental study. PMID:20839340
NASA Astrophysics Data System (ADS)
Zhou, Gang; Liu, Naicheng; Wang, Zhenheng; Shi, Tongguo; Gan, Jingjing; Wang, Zhenzhen; Zhang, Junfeng
2017-02-01
Nanoparticle-based applications for diagnostics and therapeutics have been extensively studied. These applications require a profound understanding of the fate of nanoparticles (NPs) in cellular environments. However, until now, few analytical methods are available and most of them rely on fluorescent properties or special elements of NPs; therefore, for NPs without observable optical properties or special elements, the existing methods are hardly applicable. In this study, we introduce a flow cytometry light scattering (FCLS)-based approach that quantifies in situ NPs accurately in mammalian cells. Continuous cells of heterogeneous human epithelial colorectal adenocarcinoma (Caco-2 cells), mouse peritoneal macrophages (MPM), and human adenocarcinomic alveolar basal epithelia (A549 cells) were cultured with NPs with certain concentrations and size. The intensity of the flow cytometric side scattered light, which indicates the quantity of NPs in the cells, was analyzed. The result shows an accurate size- and dose-dependent uptake of Au NPs (5, 30, 250 nm) in Caco-2 cells. The size- and dose- dependence of Au NPs (5, 30, 250 nm) and carbon NPs (50, 500 nm) in cells was validated by transmission electron microscope (TEM). This paper demonstrates the great potential of flow cytometry light scattering in the quantitative study of the size and dose effect on in situ metallic or non-metallic NPs in mammalian cells.
Flow cytometric HyPer-based assay for hydrogen peroxide.
Lyublinskaya, O G; Antonov, S A; Gorokhovtsev, S G; Pugovkina, N A; Kornienko, Ju S; Ivanova, Ju S; Shatrova, A N; Aksenov, N D; Zenin, V V; Nikolsky, N N
2018-05-30
HyPer is a genetically encoded fluorogenic sensor for hydrogen peroxide which is generally used for the ratiometric imaging of H 2 O 2 fluxes in living cells. Here, we demonstrate the advantages of HyPer-based ratiometric flow cytometry assay for H 2 O 2 , by using K562 and human mesenchymal stem cell lines expressing HyPer. We show that flow cytometry analysis is suitable to detect HyPer response to submicromolar concentrations of extracellularly added H 2 O 2 that is much lower than concentrations addressed previously in the other HyPer-based assays (such as cell imaging or fluorimetry). Suggested technique is also much more sensitive to hydrogen peroxide than the widespread flow cytometry assay exploiting H 2 O 2 -reactive dye H 2 DCFDA and, contrary to the H 2 DCFDA-based assay, can be employed for the kinetic studies of H 2 O 2 utilization by cells, including measurements of the rate constants of H 2 O 2 removal. In addition, flow cytometry multi-parameter ratiometric measurements enable rapid and high-throughput detection of endogenously generated H 2 O 2 in different subpopulations of HyPer-expressing cells. To sum up, HyPer can be used in multi-parameter flow cytometry studies as a highly sensitive indicator of intracellular H 2 O 2 . Copyright © 2018. Published by Elsevier Inc.
Web-based analysis and publication of flow cytometry experiments.
Kotecha, Nikesh; Krutzik, Peter O; Irish, Jonathan M
2010-07-01
Cytobank is a Web-based application for storage, analysis, and sharing of flow cytometry experiments. Researchers use a Web browser to log in and use a wide range of tools developed for basic and advanced flow cytometry. In addition to providing access to standard cytometry tools from any computer, Cytobank creates a platform and community for developing new analysis and publication tools. Figure layouts created on Cytobank are designed to allow transparent access to the underlying experiment annotation and data processing steps. Since all flow cytometry files and analysis data are stored on a central server, experiments and figures can be viewed or edited by anyone with the proper permission, from any computer with Internet access. Once a primary researcher has performed the initial analysis of the data, collaborators can engage in experiment analysis and make their own figure layouts using the gated, compensated experiment files. Cytobank is available to the scientific community at http://www.cytobank.org. (c) 2010 by John Wiley & Sons, Inc.
Web-Based Analysis and Publication of Flow Cytometry Experiments
Kotecha, Nikesh; Krutzik, Peter O.; Irish, Jonathan M.
2014-01-01
Cytobank is a web-based application for storage, analysis, and sharing of flow cytometry experiments. Researchers use a web browser to log in and use a wide range of tools developed for basic and advanced flow cytometry. In addition to providing access to standard cytometry tools from any computer, Cytobank creates a platform and community for developing new analysis and publication tools. Figure layouts created on Cytobank are designed to allow transparent access to the underlying experiment annotation and data processing steps. Since all flow cytometry files and analysis data are stored on a central server, experiments and figures can be viewed or edited by anyone with the proper permissions from any computer with Internet access. Once a primary researcher has performed the initial analysis of the data, collaborators can engage in experiment analysis and make their own figure layouts using the gated, compensated experiment files. Cytobank is available to the scientific community at www.cytobank.org PMID:20578106
Review of methods to probe single cell metabolism and bioenergetics
Vasdekis, Andreas E.; Stephanopoulos, Gregory
2014-10-31
The sampling and manipulation of cells down to the individual has been of substantial interest since the very beginning of Life Sciences. Herein, our objective is to highlight the most recent developments in single cell manipulation, as well as pioneering ones. First, flow-through methods will be discussed, namely methods in which the single cells flow continuously in an ordered manner during their analysis. This section will be followed by confinement techniques that enable cell isolation and confinement in one, two- or three-dimensions. Flow cytometry and droplet microfluidics are the two most common methods of flow-through analysis. While both are high-throughputmore » techniques, their difference lays in the fact that the droplet encapsulated cells experience a restricted and personal microenvironment, while in flow cytometry cells experience similar nutrient and stimuli initial concentrations. These methods are rather well established; however, they recently enabled immense strides in single cell phenotypic analysis, namely the identification and analysis of metabolically distinct individuals from an isogenic population using both droplet microfluidics and flow cytometry.« less
USDA-ARS?s Scientific Manuscript database
We have identified a method whereby Lolium multiflorum (Lm) or L. arundinaceum (Fa) genomes are preferentially eliminated through a mitotic loss behavior in interspecific Lm x Fa F1 hybrids, generating either dihaploid Lm lines or Fa lines. Flow cytometry, a method for rapidly characterizing optical...
NASA Astrophysics Data System (ADS)
Regmi, Raju; Mohan, Kavya; Mondal, Partha Pratim
2014-09-01
Visualization of intracellular organelles is achieved using a newly developed high throughput imaging cytometry system. This system interrogates the microfluidic channel using a sheet of light rather than the existing point-based scanning techniques. The advantages of the developed system are many, including, single-shot scanning of specimens flowing through the microfluidic channel at flow rate ranging from micro- to nano- lit./min. Moreover, this opens-up in-vivo imaging of sub-cellular structures and simultaneous cell counting in an imaging cytometry system. We recorded a maximum count of 2400 cells/min at a flow-rate of 700 nl/min, and simultaneous visualization of fluorescently-labeled mitochondrial network in HeLa cells during flow. The developed imaging cytometry system may find immediate application in biotechnology, fluorescence microscopy and nano-medicine.
Böttcher, S; Ritgen, M; Pott, C; Brüggemann, M; Raff, T; Stilgenbauer, S; Döhner, H; Dreger, P; Kneba, M
2004-10-01
The clinically most suitable method for minimal residual disease (MRD) detection in chronic lymphocytic leukemia is still controversial. We prospectively compared MRD assessment in 158 blood samples of 74 patients with CLL after stem cell transplantation (SCT) using four-color flow cytometry (MRD flow) in parallel with consensus IgH-PCR and ASO IgH real-time PCR (ASO IgH RQ-PCR). In 25 out of 106 samples (23.6%) with a polyclonal consensus IgH-PCR pattern, MRD flow still detected CLL cells, proving higher sensitivity of flow cytometry over PCR-genescanning with consensus IgH-primers. Of 92 samples, 14 (15.2%) analyzed in parallel by MRD flow and by ASO IgH RQ-PCR were negative by our flow cytometric assay but positive by PCR, thus demonstrating superior sensitivity of RQ-PCR with ASO primers. Quantitative MRD levels measured by both methods correlated well (r=0.93). MRD detection by flow and ASO IgH RQ-PCR were equally suitable to monitor MRD kinetics after allogeneic SCT, but the PCR method detected impending relapses after autologous SCT earlier. An analysis of factors that influence sensitivity and specificity of flow cytometry for MRD detection allowed to devise further improvements of this technique.
Mesenchymal Stem Cells for Vascular Target Discovery in Breast Cancer-Associated Angiogenesis
2005-09-01
demonstrating this marker as demonstrated by flow cytometry . These GFP+ MSCs were subsequently analyzed for expression of commonly reported markers of...phenotypically and genotypically analyzed by flow cytometry and gene chip analysis, respectively. We have also shown that MSCs can then be stimulated to...positive MSCs retrieved by collagenase digestion of the Matrigel plug and sorted by flow cytometry . Sorting of these retrieved cells based on co-expression
Probing Tumor Microenvironment With In Vivo Phage Display
2014-10-01
C). (C) Dot plots showing mCherry expression on the X axis and fibroblast activation protein ( FAP ) or rabbit isotype control staining in the Y...by flow cytometry-based cell sorting using an antibody against fibroblast activation protein ( FAP ). During the optimization steps, flow cytometry...expression of αvβ3 and αvβ5 integrins, neuropilin-1 (NRP-1), and fibroblast activation protein ( FAP ) in hb6011 CAFs was analyzed by flow cytometry
Biomass measurement by flow cytometry during solid-state fermentation of basidiomycetes.
Steudler, Susanne; Böhmer, Ulrike; Weber, Jost; Bley, Thomas
2015-02-01
Solid-state fermentation (SSF) is a robust process that is well suited to the on-site cultivation of basidiomycetes that produce enzymes for the treatment of lignocellulosics. Reliable methods for biomass quantification are essential for the analysis of fungal growth kinetics. However, direct biomass determination is not possible during SSF because the fungi grow into the substrate and use it as a nutrient source. This necessitates the use of indirect methods that are either very laborious and time consuming or can only provide biomass measurements during certain growth periods. Here, we describe the development and optimization of a new rapid method for fungal biomass determination during SSF that is based on counting fungal nuclei by flow cytometry. Fungal biomass was grown on an organic substrate and its concentration was measured by isolating the nuclei from the fungal hyphae after cell disruption, staining them with SYTOX(®) Green, and then counting them using a flow cytometer. A calibration curve relating the dry biomass of the samples to their concentrations of nuclei was established. Multiple buffers and disruption methods were tested. The results obtained were compared with values determined using the method of ergosterol determination, a classical technique for fungal biomass measurement during SSF. Our new approach can be used to measure fungal biomass on a range of different scales, from 15 mL cultures to a laboratory reactor with a working volume of 10 L (developed by the Research Center for Medical Technology and Biotechnology (fzmb GmbH)). © 2014 International Society for Advancement of Cytometry. © 2014 International Society for Advancement of Cytometry.
Juzwa, W; Duber, A; Myszka, K; Białas, W; Czaczyk, K
2016-09-01
In this study the design of a flow cytometry-based procedure to facilitate the detection of adherent bacteria from food-processing surfaces was evaluated. The measurement of the cellular redox potential (CRP) of microbial cells was combined with cell sorting for the identification of microorganisms. The procedure enhanced live/dead cell discrimination owing to the measurement of the cell physiology. The microbial contamination of the surface of a stainless steel conveyor used to process button mushrooms was evaluated in three independent experiments. The flow cytometry procedure provided a step towards monitoring of contamination and enabled the assessment of microbial food safety hazards by the discrimination of active, mid-active and non-active bacterial sub-populations based on determination of their cellular vitality and subsequently single cell sorting to isolate microbial strains from discriminated sub-populations. There was a significant correlation (r = 0.97; p < 0.05) between the bacterial cell count estimated by the pour plate method and flow cytometry, despite there being differences in the absolute number of cells detected. The combined approach of flow cytometric CRP measurement and cell sorting allowed an in situ analysis of microbial cell vitality and the identification of species from defined sub-populations, although the identified microbes were limited to culturable cells.
Flow Cytometry: Evolution of Microbiological Methods for Probiotics Enumeration.
Pane, Marco; Allesina, Serena; Amoruso, Angela; Nicola, Stefania; Deidda, Francesca; Mogna, Luca
2018-05-14
The purpose of this trial was to verify that the analytical method ISO 19344:2015 (E)-IDF 232:2015 (E) is valid and reliable for quantifying the concentration of the probiotic Lactobacillus rhamnosus GG (ATCC 53103) in a finished product formulation. Flow cytometry assay is emerging as an alternative rapid method for microbial detection, enumeration, and population profiling. The use of flow cytometry not only permits the determination of viable cell counts but also allows for enumeration of damaged and dead cell subpopulations. Results are expressed as TFU (Total Fluorescent Units) and AFU (Active Fluorescent Units). In December 2015, the International Standard ISO 19344-IDF 232 "Milk and milk products-Starter cultures, probiotics and fermented products-Quantification of lactic acid bacteria by flow cytometry" was published. This particular ISO can be applied universally and regardless of the species of interest. Analytical method validation was conducted on 3 different industrial batches of L. rhamnosus GG according to USP39<1225>/ICH Q2R1 in term of: accuracy, precision (repeatability), intermediate precision (ruggedness), specificity, limit of quantification, linearity, range, robustness. The data obtained on the 3 batches of finished product have significantly demonstrated the validity and robustness of the cytofluorimetric analysis. On the basis of the results obtained, the ISO 19344:2015 (E)-IDF 232:2015 (E) "Quantification of lactic acid bacteria by flow cytometry" can be used for the enumeration of L. rhamnosus GG in a finished product formulation.
Pelletier, Margery G. H.; Szymczak, Klaudia; Barbeau, Anna M.; Prata, Gianna N.; O’Fallon, Kevin S.; Gaines, Peter
2016-01-01
Neutrophils and macrophages differentiate from common myeloid progenitors in the bone marrow, where they undergo nuclear morphologic changes during maturation. During this process, both cell types acquire critical innate immune functions that include phagocytosis of pathogens, and for neutrophils the release of nuclear material called nuclear extracellular traps (NETs). Primary cells used to study these functions are typically purified from mature mouse tissues, but bone marrow-derived ex vivo cultures provide more abundant numbers of progenitors and functionally mature cells. Routine analyses of these cells use conventional microscopy and flow cytometry, which present limitations; microscopy is laborious and subjective, whereas flow cytometry lacks spatial resolution. Here we describe methods to generate enriched populations of neutrophils or macrophages from cryopreserved mouse bone marrow cultured ex vivo, and to use imaging flow cytometry that combines the resolution of microscopy with flow cytometry to analyze cells for morphologic features, phagocytosis, and NETosis. PMID:27663441
Augmenting Trastuzumab Therapy against Breast Cancer through Selective Activation of NK Cells
2014-12-01
purity as defined by CD3-CD56+ flow cytometry ) and activation (>50% expression of CD137). Breast cancer cell lines including MCF7 (A and E...purity as defined by CD3-CD56+ flow cytometry ) and activation (>50% expression of CD137). Chromium-labeled breast cancer cell lines including MCF7 (A...and Whiteside, T.L. 2007. A novel multiparametric flow cytometry -based cytotoxicity assay simultaneously immunophenotypes effector cells: comparisons
Naivar, Mark A.; Wilder, Mark E.; Habbersett, Robert C.; Woods, Travis A.; Sebba, David S.; Nolan, John P.; Graves, Steven W.
2014-01-01
Fully digital data acquisition systems for use in flow cytometry provide excellent flexibility and precision. Here, we demonstrate the development of a low cost, small, and low power digital flow cytometry data acquisition system using a single microcontroller chip with an integrated analog to digital converter (ADC). Our demonstration system uses a commercially available evaluation board making the system simple to integrate into a flow cytometer. We have evaluated this system using calibration microspheres analyzed on commercial, slow-flow, and CCD based flow cytometers. In our evaluations, our demonstration data system clearly resolves all eight peaks of a Rainbow microsphere set on both a slow-flow flow cytometer and a retrofitted BD FACScalibur, which indicates it has the sensitivity and resolution required for most flow cytometry applications. It is also capable of millisecond time resolution, full waveform collection, and selective triggering of data collection from a CCD camera. The capability of our demonstration system suggests that the use of microcontrollers for flow cytometry digital data-acquisition will be increasingly valuable for extending the life of older cytometers and provides a compelling data-system design approach for low-cost, portable flow cytometers. PMID:19852060
Naivar, Mark A; Wilder, Mark E; Habbersett, Robert C; Woods, Travis A; Sebba, David S; Nolan, John P; Graves, Steven W
2009-12-01
Fully digital data acquisition systems for use in flow cytometry provide excellent flexibility and precision. Here, we demonstrate the development of a low cost, small, and low power digital flow cytometry data acquisition system using a single microcontroller chip with an integrated analog to digital converter (ADC). Our demonstration system uses a commercially available evaluation board making the system simple to integrate into a flow cytometer. We have evaluated this system using calibration microspheres analyzed on commercial, slow-flow, and CCD-based flow cytometers. In our evaluations, our demonstration data system clearly resolves all eight peaks of a Rainbow microsphere set on both a slow-flow flow cytometer and a retrofitted BD FACScalibur, which indicates it has the sensitivity and resolution required for most flow cytometry applications. It is also capable of millisecond time resolution, full waveform collection, and selective triggering of data collection from a CCD camera. The capability of our demonstration system suggests that the use of microcontrollers for flow cytometry digital data-acquisition will be increasingly valuable for extending the life of older cytometers and provides a compelling data-system design approach for low-cost, portable flow cytometers.
Clinical cytometry and progress in HLA antibody detection.
Bray, Robert A; Tarsitani, Christine; Gebel, Howard M; Lee, Jar-How
2011-01-01
For most solid organ and selected stem cell transplants, antibodies against mismatched HLA antigens can lead to early and late graft failure. In recognition of the clinical significance of these antibodies, HLA antibody identification is one of the most critical functions of histocompatibility laboratories. Early methods employed cumbersome and insensitive complement-dependent cytotoxicity assays with a visual read-out. A little over 20 years ago flow cytometry entered the realm of antibody detection with the introduction of the flow cytometric crossmatch. Cytometry's increased sensitivity and objectivity quickly earned it popularity as a preferred crossmatch method especially for sensitized recipients. Although a sensitive method, the flow crossmatch was criticized as being "too sensitive" as false positive reactions were a know drawback. In part, the shortcomings of the flow crossmatch were due to the lack of corresponding sensitive and specific HLA antibody screening assays. However, in the mid 1990s, solid phase assays, capable of utilizing standard flow cytometers, were developed. These assays used microparticles coated with purified HLA molecules. Hence, the era of solid-phase, microparticle technology for HLA antibody detection was born permitting the sensitive and specific detection of HLA antibody. It was now possible to provide better correlation between HLA antibody detection and the flow cytometric crossmatch. This flow-based technology was soon followed by adaptation to the Luminex platform permitting a mutltiplexed approach for the identification and characterization of HLA antibodies. It is hoped that these technologies will ultimately lead to the identification of parameters that best correlate with and/or predict transplant outcomes. Copyright © 2011 Elsevier Inc. All rights reserved.
Joachimsthal, Eva L; Ivanov, Volodymyr; Tay, Joo-Hwa; Tay, Stephen T-L
2003-03-01
Conventional methods for bacteriological testing of water quality take long periods of time to complete. This makes them inappropriate for a shipping industry that is attempting to comply with the International Maritime Organization's anticipated regulations for ballast water discharge. Flow cytometry for the analysis of marine and ship's ballast water is a comparatively fast and accurate method. Compared to a 5% standard error for flow cytometry analysis the standard methods of culturing and epifluorescence analysis have errors of 2-58% and 10-30%, respectively. Also, unlike culturing methods, flow cytometry is capable of detecting both non-viable and viable but non-culturable microorganisms which can still pose health risks. The great variability in both cell concentrations and microbial content for the samples tested is an indication of the difficulties facing microbial monitoring programmes. The concentration of microorganisms in the ballast tank was generally lower than in local seawater. The proportion of aerobic, microaerophilic, and facultative anaerobic microorganisms present appeared to be influenced by conditions in the ballast tank. The gradual creation of anaerobic conditions in a ballast tank could lead to the accumulation of facultative anaerobic microorganisms, which might represent a potential source of pathogenic species.
Chan, Leo Li-Ying; Kuksin, Dmitry; Laverty, Daniel J; Saldi, Stephanie; Qiu, Jean
2015-05-01
The ability to accurately determine cell viability is essential to performing a well-controlled biological experiment. Typical experiments range from standard cell culturing to advanced cell-based assays that may require cell viability measurement for downstream experiments. The traditional cell viability measurement method has been the trypan blue (TB) exclusion assay. However, since the introduction of fluorescence-based dyes for cell viability measurement using flow or image-based cytometry systems, there have been numerous publications comparing the two detection methods. Although previous studies have shown discrepancies between TB exclusion and fluorescence-based viability measurements, image-based morphological analysis was not performed in order to examine the viability discrepancies. In this work, we compared TB exclusion and fluorescence-based viability detection methods using image cytometry to observe morphological changes due to the effect of TB on dead cells. Imaging results showed that as the viability of a naturally-dying Jurkat cell sample decreased below 70 %, many TB-stained cells began to exhibit non-uniform morphological characteristics. Dead cells with these characteristics may be difficult to count under light microscopy, thus generating an artificially higher viability measurement compared to fluorescence-based method. These morphological observations can potentially explain the differences in viability measurement between the two methods.
Hsiao, Chiaowen; Liu, Mengya; Stanton, Rick; McGee, Monnie; Qian, Yu
2015-01-01
Abstract Flow cytometry (FCM) is a fluorescence‐based single‐cell experimental technology that is routinely applied in biomedical research for identifying cellular biomarkers of normal physiological responses and abnormal disease states. While many computational methods have been developed that focus on identifying cell populations in individual FCM samples, very few have addressed how the identified cell populations can be matched across samples for comparative analysis. This article presents FlowMap‐FR, a novel method for cell population mapping across FCM samples. FlowMap‐FR is based on the Friedman–Rafsky nonparametric test statistic (FR statistic), which quantifies the equivalence of multivariate distributions. As applied to FCM data by FlowMap‐FR, the FR statistic objectively quantifies the similarity between cell populations based on the shapes, sizes, and positions of fluorescence data distributions in the multidimensional feature space. To test and evaluate the performance of FlowMap‐FR, we simulated the kinds of biological and technical sample variations that are commonly observed in FCM data. The results show that FlowMap‐FR is able to effectively identify equivalent cell populations between samples under scenarios of proportion differences and modest position shifts. As a statistical test, FlowMap‐FR can be used to determine whether the expression of a cellular marker is statistically different between two cell populations, suggesting candidates for new cellular phenotypes by providing an objective statistical measure. In addition, FlowMap‐FR can indicate situations in which inappropriate splitting or merging of cell populations has occurred during gating procedures. We compared the FR statistic with the symmetric version of Kullback–Leibler divergence measure used in a previous population matching method with both simulated and real data. The FR statistic outperforms the symmetric version of KL‐distance in distinguishing equivalent from nonequivalent cell populations. FlowMap‐FR was also employed as a distance metric to match cell populations delineated by manual gating across 30 FCM samples from a benchmark FlowCAP data set. An F‐measure of 0.88 was obtained, indicating high precision and recall of the FR‐based population matching results. FlowMap‐FR has been implemented as a standalone R/Bioconductor package so that it can be easily incorporated into current FCM data analytical workflows. © 2015 International Society for Advancement of Cytometry PMID:26274018
Shaver, Aaron C; Greig, Bruce W; Mosse, Claudio A; Seegmiller, Adam C
2015-05-01
Optimizing a clinical flow cytometry panel can be a subjective process dependent on experience. We develop a quantitative method to make this process more rigorous and apply it to B lymphoblastic leukemia/lymphoma (B-ALL) minimal residual disease (MRD) testing. We retrospectively analyzed our existing three-tube, seven-color B-ALL MRD panel and used our novel method to develop an optimized one-tube, eight-color panel, which was tested prospectively. The optimized one-tube, eight-color panel resulted in greater efficiency of time and resources with no loss in diagnostic power. Constructing a flow cytometry panel using a rigorous, objective, quantitative method permits optimization and avoids problems of interdependence and redundancy in a large, multiantigen panel. Copyright© by the American Society for Clinical Pathology.
NASA Astrophysics Data System (ADS)
Liu, Rongrong; Wang, Cheng; Hu, Cheng; Wang, Xueding; Wei, Xunbin
2014-02-01
Melanoma, a malignant tumor of melanocytes, is the most serious type of skin cancer in the world. It accounts for about 80% of deaths of all skin cancer. For cancer detection, circulating tumor cells (CTCs) serve as a marker for metastasis development, cancer recurrence, and therapeutic efficacy. Melanoma tumor cells have high content of melanin, which has high light absorption and can serve as endogenous biomarker for CTC detection without labeling. Here, we have developed an in vivo photoacoustic flow cytometry (PAFC) to monitor the metastatic process of melanoma cancer by counting CTCs of melanoma tumor bearing mice in vivo. To test in vivo PAFC's capability of detecting melanoma cancer, we have constructed a melanoma tumor model by subcutaneous inoculation of highly metastatic murine melanoma cancer cells, B16F10. In order to effectively distinguish the targeting PA signals from background noise, we have used the algorithm of Wavelet denoising method to reduce the background noise. The in vivo flow cytometry (IVFC) has shown a great potential for detecting circulating tumor cells quantitatively in the blood stream. Compared with fluorescence-based in vivo flow cytometry (IVFC), PAFC technique can be used for in vivo, label-free, and noninvasive detection of circulating tumor cells (CTCs).
Label-free high-throughput imaging flow cytometry
NASA Astrophysics Data System (ADS)
Mahjoubfar, A.; Chen, C.; Niazi, K. R.; Rabizadeh, S.; Jalali, B.
2014-03-01
Flow cytometry is an optical method for studying cells based on their individual physical and chemical characteristics. It is widely used in clinical diagnosis, medical research, and biotechnology for analysis of blood cells and other cells in suspension. Conventional flow cytometers aim a laser beam at a stream of cells and measure the elastic scattering of light at forward and side angles. They also perform single-point measurements of fluorescent emissions from labeled cells. However, many reagents used in cell labeling reduce cellular viability or change the behavior of the target cells through the activation of undesired cellular processes or inhibition of normal cellular activity. Therefore, labeled cells are not completely representative of their unaltered form nor are they fully reliable for downstream studies. To remove the requirement of cell labeling in flow cytometry, while still meeting the classification sensitivity and specificity goals, measurement of additional biophysical parameters is essential. Here, we introduce an interferometric imaging flow cytometer based on the world's fastest continuous-time camera. Our system simultaneously measures cellular size, scattering, and protein concentration as supplementary biophysical parameters for label-free cell classification. It exploits the wide bandwidth of ultrafast laser pulses to perform blur-free quantitative phase and intensity imaging at flow speeds as high as 10 meters per second and achieves nanometer-scale optical path length resolution for precise measurements of cellular protein concentration.
Rapid susceptibility testing of fungi by flow cytometry using vital staining.
Wenisch, C; Linnau, K F; Parschalk, B; Zedtwitz-Liebenstein, K; Georgopoulos, A
1997-01-01
A 1-h assay for antifungal susceptibility testing measuring the impairment of fungal metabolic activity was developed. Yeast viability was analyzed by flow cytometry with a novel fluorescent probe, FUN-1, which emits a red fluorescence when the yeast is metabolically active. For nine Candida albicans strains tested, this method yielded results comparable to those obtained by the standard M27 procedure for amphotericin B, flucytosine, fluconazole, and ketoconazole. Whether the flow cytometry antifungal susceptibility test results correlate with the in vivo activities of the drugs remains to determined. PMID:8968873
Utilization of microparticles in next-generation assays for microflow cytometers.
Kim, Jason S; Ligler, Frances S
2010-11-01
Micron-sized particles have primarily been used in microfabricated flow cytometers for calibration purposes and proof-of-concept experiments. With increasing frequency, microparticles are serving as a platform for assays measured in these small analytical devices. Light scattering has been used to measure the agglomeration of antibody-coated particles in the presence of an antigen. Impedance detection is another technology being integrated into microflow cytometers for microparticle-based assays. Fluorescence is the most popular detection method in flow cytometry, enabling highly sensitive multiplexed assays. Finally, magnetic particles have also been used to measure antigen levels using a magnetophoretic micro-device. We review the progress of microparticle-based assays in microflow cytometry in terms of the advantages and limitations of each approach.
Oldaker, Teri; Whitby, Liam; Saber, Maryam; Holden, Jeannine; Wallace, Paul K; Litwin, Virginia
2018-01-01
Over the past six years, a diverse group of stakeholders have put forth recommendations regarding the analytical validation of flow cytometric methods and described in detail the differences between cell-based and traditional soluble analyte assay validations. This manuscript is based on these general recommendations as well as the published experience of experts in the area of PNH testing. The goal is to provide practical assay-specific guidelines for the validation of high-sensitivity flow cytometric PNH assays. Examples of the reports and validation data described herein are provided in Supporting Information. © 2017 International Clinical Cytometry Society. © 2017 International Clinical Cytometry Society.
Marjanovič, Igor; Kandušer, Maša; Miklavčič, Damijan; Keber, Mateja Manček; Pavlin, Mojca
2014-12-01
In this study, we compared three different methods used for quantification of gene electrotransfer efficiency: fluorescence microscopy, flow cytometry and spectrofluorometry. We used CHO and B16 cells in a suspension and plasmid coding for GFP. The aim of this study was to compare and analyse the results obtained by fluorescence microscopy, flow cytometry and spectrofluorometry and in addition to analyse the applicability of spectrofluorometry for quantifying gene electrotransfer on cells in a suspension. Our results show that all the three methods detected similar critical electric field strength, around 0.55 kV/cm for both cell lines. Moreover, results obtained on CHO cells showed that the total fluorescence intensity and percentage of transfection exhibit similar increase in response to increase electric field strength for all the three methods. For B16 cells, there was a good correlation at low electric field strengths, but at high field strengths, flow cytometer results deviated from results obtained by fluorescence microscope and spectrofluorometer. Our study showed that all the three methods detected similar critical electric field strengths and high correlations of results were obtained except for B16 cells at high electric field strengths. The results also demonstrated that flow cytometry measures higher values of percentage transfection compared to microscopy. Furthermore, we have demonstrated that spectrofluorometry can be used as a simple and consistent method to determine gene electrotransfer efficiency on cells in a suspension.
Articular Cartilage Repair Through Muscle Cell-Based Tissue Engineering
2010-03-01
results suggest that sFlt-1 has more of an enhancing effect in vivo. With cell markers and flow cytometry , investiga- tors at our laboratory have...were analyzed by flow cytometry . They were immunostained by desmin, vimentin and MyoD and their chondrogenic potential was evaluated under the...M1, M2, and M3) and 3 F-MDSC populations (F1, F2, and F3) were characterized by flow cytometry for CD34 and Sca1 expression. MDSCs were labeled with
Immunophenotyping by slide-based cytometry and by flow cytometry are comparable
NASA Astrophysics Data System (ADS)
Gerstner, Andreas O.; Laffers, Wiebke; Mittag, Anja; Daehnert, Ingo; Lenz, Domnik; Bootz, Friedrich; Bocsi, Jozsef; Tarnok, Attila
2005-03-01
Immunophenotyping of peripheral blood leukocytes (PBLs) is performed by flow cytometry (FCM) as the golden standard. Slide based cytometry systems for example laser scanning cytometer (LSC) can give additional information (repeated staining and scanning, morphology). In order to adequately judge on the clinical usefulness of immunophenotyping by LSC it is obligatory to compare it with the long established FCM assays. We performed this study to systematically compare the two methods, FCM and LSC for immunophenotyping and to test the correlation of the results. Leucocytes were stained with directly labeled monoclonal antibodies with whole blood staining method. Aliquots of the same paraformaldehyde fixed specimens were analyzed in a FACScan (BD-Biosciences) using standard protocols and parallel with LSC (CompuCyte) after placing to glass slide, drying and fixation by aceton and 7-AAD staining. Calculating the percentage distribution of PBLs obtained by LSC and by FCM shows very good correlation with regression coefficients close to 1.0 for the major populations (neutrophils, lymphocytes, and monocytes), as well as for the lymphocyte sub-populations (T-helper-, T-cytotoxic-, B-, NK-cells). LSC can be recommended for immunophenotyping of PBLs especially in cases where only very limited sample volumes are available or where additional analysis of the cells" morphology is important. There are limitations in the detection of rare leucocytes or weak antigens where appropriate amplification steps for immunofluorescence should be engaged.
The role of flow cytometry in companion animal diagnostic medicine.
Tarrant, Jacqueline M
2005-11-01
Flow cytometry is a powerful tool for characterising the composition of complex cell populations. The accuracy and precision of this technology for describing and enumerating cells exceeds traditional methods. The number of diagnostic veterinary laboratories with access to a dedicated machine is increasing, and there is the potential to offer a clinical flow cytometry service. The improved availability of monoclonal antibodies (mAb) to cell markers expressed by the leukocytes of companion animals, permits the implementation of comprehensive mAb panels suitable for diagnosis of lympho- and myeloproliferative disease. Reticulated erythrocyte and platelet quantification, antiglobulin assays for immune-mediated cytopenias, lymphocyte subset analysis, and immunophenotyping of lymphoma and leukemia, have been validated for companion animal samples on the flow cytometer. It is now timely to consider the role of flow cytometry in diagnostic practice, and the requirement for quality assurance and standardization of testing procedures.
Perruche, Sylvain; Kleinclauss, François; Lienard, Agnès; Robinet, Eric; Tiberghien, Pierre; Saas, Philippe
2004-11-01
The monitoring of immune reconstitution in murine models of HC transplantation, using accurate and automated methods, is necessary in view of the recent developments of hematopoietic cell (HC) transplantation (including reduced intensity conditioning regimens) as well as emerging immunological concepts (such as the involvement of dendritic cells or regulatory T cells). Here, we describe the use of a single-platform approach based on flow cytometry and tubes that contain a defined number of microbeads to evaluate absolute blood cell counts in mice. This method, previously used in humans to quantify CD34+ stem cells or CD4+ T cells in HIV infected patients, was adapted for mouse blood samples. A CD45 gating strategy in this "lyse no wash" protocol makes it possible to discriminate erythroblasts or red blood cell debris from CD45+ leukocytes, thus avoiding cell loss. Tubes contain a lyophilized brightly fluorescent microbead pellet permitting the acquisition of absolute counts of leukocytes after flow cytometric analysis. We compared this method to determine absolute counts of circulating cells with another method combining Unopette reservoir diluted blood samples, hemocytometer, microscopic examination and flow cytometry. The sensitivity of this single-platform approach was evaluated in different situations encountered in allogeneic HC transplantation, including immune cell depletion after different conditioning regimens, activation status of circulating cells after transplantation, evaluation of in vivo cell depletion and hematopoietic progenitor mobilization in the periphery. This single-platform flow cytometric assay can also be proposed to standardize murine (or other mammalian species) leukocyte count determination for physiological, pharmacological/toxicological and diagnostic applications in veterinary practice.
Grimaldi, E; Del Vecchio, L; Scopacasa, F; Lo Pardo, C; Capone, F; Pariante, S; Scalia, G; De Caterina, M
2009-04-01
The Abbot Cell-Dyn Sapphire is a new generation haematology analyser. The system uses optical/fluorescence flow cytometry in combination with electronic impedance to produce a full blood count. Optical and impedance are the default methods for platelet counting while automated CD61-immunoplatelet analysis can be run as selectable test. The aim of this study was to determine the platelet count performance of the three counting methods available on the instrument and to compare the results with those provided by Becton Dickinson FACSCalibur flow cytometer used as reference method. A lipid interference experiment was also performed. Linearity, carryover and precision were good, and satisfactory agreement with reference method was found for the impedance, optical and CD61-immunoplatelet analysis, although this latter provided the closest results in comparison with flow cytometry. In the lipid interference experiment, a moderate inaccuracy of optical and immunoplatelet counts was observed starting from a very high lipid value.
Bankier, Claire; Cheong, Yuen; Mahalingam, Suntharavathanan; Edirisinghe, Mohan; Ren, Guogang; Cloutman-Green, Elaine; Ciric, Lena
2018-01-01
Bacterial cell quantification after exposure to antimicrobial compounds varies widely throughout industry and healthcare. Numerous methods are employed to quantify these antimicrobial effects. With increasing demand for new preventative methods for disease control, we aimed to compare and assess common analytical methods used to determine antimicrobial effects of novel nanoparticle combinations on two different pathogens. Plate counts of total viable cells, flow cytometry (LIVE/DEAD BacLight viability assay) and qPCR (viability qPCR) were used to assess the antimicrobial activity of engineered nanoparticle combinations (NPCs) on Gram-positive (Staphylococcus aureus) and Gram-negative (Pseudomonas aeruginosa) bacteria at different concentrations (0.05, 0.10 and 0.25 w/v%). Results were analysed using linear models to assess the effectiveness of different treatments. Strong antimicrobial effects of the three NPCs (AMNP0-2) on both pathogens could be quantified using the plate count method and flow cytometry. The plate count method showed a high log reduction (>8-log) for bacteria exposed to high NPC concentrations. We found similar antimicrobial results using the flow cytometry live/dead assay. Viability qPCR analysis of antimicrobial activity could not be quantified due to interference of NPCs with qPCR amplification. Flow cytometry was determined to be the best method to measure antimicrobial activity of the novel NPCs due to high-throughput, rapid and quantifiable results.
Majeed, Muhammed; Majeed, Shaheen; Nagabhushanam, Kalyanam; Punnapuzha, Ardra; Philip, Sheena; Mundkur, Lakshmi
2018-01-01
Accurate enumeration of bacterial count in probiotic formulation is imperative to ensure that the product adheres to regulatory standards and citation in consumer product label. Standard methods like plate count, can enumerate only replicating bacterial population under selected culture conditions. Viable but non culturable bacteria (VBNC) retain characteristics of living cells and can regain cultivability by a process known as resuscitation. This is a protective mechanism adapted by bacteria to evade stressful environmental conditions. B. coagulans MTCC 5856(LactoSpore®) is a probiotic endospore which can survive for decades in hostile environments without dividing. In the present study, we explored the use of flow cytometry to enumerate the viable count of B. coagulans MTCC 5856 under acidic and alkaline conditions, high temperature and in commercial formulations like compressed tablets and capsules. Flow cytometry (FCM) was comparable to plate count method when the spores were counted at physiological conditions. We show that VBNC state is induced in B. coagulans MTCC 5856by high temperature and acidic pH. The cells get resuscitated under physiological conditions and FCM was sensitive to detect the VBNC spores. Flow cytometry showed excellent ability to assess the viable spore count in commercial probiotic formulations of B. coagulans MTCC 5856. The results establish Flow cytometry as a reliable method to count viable bacteria in commercial probiotic preparations. Sporulation as well as existence as VBNC could contribute to the extreme stability of B. coagulans MTCC 5856.
Majeed, Muhammed; Majeed, Shaheen; Nagabhushanam, Kalyanam; Punnapuzha, Ardra; Philip, Sheena
2018-01-01
Accurate enumeration of bacterial count in probiotic formulation is imperative to ensure that the product adheres to regulatory standards and citation in consumer product label. Standard methods like plate count, can enumerate only replicating bacterial population under selected culture conditions. Viable but non culturable bacteria (VBNC) retain characteristics of living cells and can regain cultivability by a process known as resuscitation. This is a protective mechanism adapted by bacteria to evade stressful environmental conditions. B. coagulans MTCC 5856(LactoSpore®) is a probiotic endospore which can survive for decades in hostile environments without dividing. In the present study, we explored the use of flow cytometry to enumerate the viable count of B. coagulans MTCC 5856 under acidic and alkaline conditions, high temperature and in commercial formulations like compressed tablets and capsules. Flow cytometry (FCM) was comparable to plate count method when the spores were counted at physiological conditions. We show that VBNC state is induced in B. coagulans MTCC 5856by high temperature and acidic pH. The cells get resuscitated under physiological conditions and FCM was sensitive to detect the VBNC spores. Flow cytometry showed excellent ability to assess the viable spore count in commercial probiotic formulations of B. coagulans MTCC 5856. The results establish Flow cytometry as a reliable method to count viable bacteria in commercial probiotic preparations. Sporulation as well as existence as VBNC could contribute to the extreme stability of B. coagulans MTCC 5856. PMID:29474436
Study of low speed flow cytometry for diffraction imaging with different chamber and nozzle designs.
Sa, Yu; Feng, Yuanming; Jacobs, Kenneth M; Yang, Jun; Pan, Ran; Gkigkitzis, Ioannis; Lu, Jun Q; Hu, Xin-Hua
2013-11-01
Achieving effective hydrodynamic focusing and flow stability at low speed presents a challenging design task in flow cytometry for studying phenomena such as cell adhesion and diffraction imaging of cells with low-cost cameras. We have developed different designs of flow chamber and sheath nozzle to accomplish the above goal. A 3D computational model of the chambers has been established to simulate the fluid dynamics in different chamber designs and measurements have been performed to determine the velocity and size distributions of the core fluid from the nozzle. Comparison of the simulation data with experimental results shows good agreement. With the computational model significant insights were gained for optimization of the chamber design and improvement of the cell positioning accuracy for study of slow moving cells. The benefit of low flow speed has been demonstrated also by reduced blurring in the diffraction images of single cells. Based on these results, we concluded that the new designs of chamber and sheath nozzle produce stable hydrodynamic focusing of the core fluid at low speed and allow detailed study of cellular morphology under various rheological conditions using the diffraction imaging method. © 2013 International Society for Advancement of Cytometry.
Tang, Peng; Wu, Jie; Liu, Hou; Liu, Youcai; Zhou, Xingding
2018-01-01
One of the newly developed methods for Assimilable organic carbon (AOC) determination is leveraged on the cell enumeration by flow cytometry (FC) which could provide a rapid and automated solution for AOC measurement. However, cell samples staining with fluorescence dye is indispensable to reduce background and machine noise. This step would bring additional cost and time consuming for this method. In this study, a green fluorescence protein (GFP) tagged strain derived of AOC testing strain Pseudomonas fluorescens P-17 (GFP-P17) was generated using Tn5 transposon mutagenesis. Continuous culture of this mutant GFP-P17 showed stable expression of eGFP signal detected by flow cytometry without staining step. In addition, this GFP-P17 strain displayed faster growth rate and had a wider range of carbon substrate utilization patterns as compared with P17 wild-type. With this strain, the capability of a new FC method with no dye staining was explored in standard acetate solution, which suggests linear correlation of counts with acetate carbon concentration. Furthermore, this FC method with GFP-P17 strain is applicable in monitoring GAC/BAC efficiency and condition as similar trends of AOC level in water treatment process were measured by both FC method and conventional spread plating count method. Therefore, this fast and easily applicable GFP-P17 based FC method could serve as a tool for routine microbiological drinking water monitoring.
Matamoros-Volante, Arturo; Moreno-Irusta, Ayelen; Torres-Rodriguez, Paulina; Giojalas, Laura; Gervasi, María G; Visconti, Pablo E; Treviño, Claudia L
2018-02-01
Is image-based flow cytometry a useful tool to study intracellular events in human sperm such as protein tyrosine phosphorylation or signaling processes? Image-based flow cytometry is a powerful tool to study intracellular events in a relevant number of sperm cells, which enables a robust statistical analysis providing spatial resolution in terms of the specific subcellular localization of the labeling. Sperm capacitation is required for fertilization. During this process, spermatozoa undergo numerous physiological changes, via activation of different signaling pathways, which are not completely understood. Classical approaches for studying sperm physiology include conventional microscopy, flow cytometry and Western blotting. These techniques present disadvantages for obtaining detailed subcellular information of signaling pathways in a relevant number of cells. This work describes a new semi-automatized analysis using image-based flow cytometry which enables the study, at the subcellular and population levels, of different sperm parameters associated with signaling. The increase in protein tyrosine phosphorylation during capacitation is presented as an example. Sperm cells were isolated from seminal plasma by the swim-up technique. We evaluated the intensity and distribution of protein tyrosine phosphorylation in sperm incubated in non-capacitation and capacitation-supporting media for 1 and 18 h under different experimental conditions. We used an antibody against FER kinase and pharmacological inhibitors in an attempt to identify the kinases involved in protein tyrosine phosphorylation during human sperm capacitation. Semen samples from normospermic donors were obtained by masturbation after 2-3 days of sexual abstinence. We used the innovative technique image-based flow cytometry and image analysis tools to segment individual images of spermatozoa. We evaluated and quantified the regions of sperm where protein tyrosine phosphorylation takes place at the subcellular level in a large number of cells. We also used immunocytochemistry and Western blot analysis. Independent experiments were performed with semen samples from seven different donors. Using image analysis tools, we developed a completely novel semi-automatic strategy useful for segmenting thousands of individual cell images obtained using image-based flow cytometry. Contrary to immunofluorescence which relies on the analysis of a limited sperm population and also on the observer, image-based flow cytometry allows for unbiased quantification and simultaneous localization of post-translational changes in an extended sperm population. Interestingly, important data can be independently analyzed by looking to the frame of interest. As an example, we evaluated the capacitation-associated increase in tyrosine phosphorylation in sperm incubated in non-capacitation and capacitation-supporting media for 1 and 18 h. As previously reported, protein tyrosine phosphorylation increases in a time-depending manner, but our method revealed that this increase occurs differentially among distinct sperm segments. FER kinase is reported to be the enzyme responsible for the increase in protein tyrosine phosphorylation in mouse sperm. Our Western blot analysis revealed for the first time the presence of this enzyme in human sperm. Using our segmentation strategy, we aimed to quantify the effect of pharmacological inhibition of FER kinase and found a marked reduction of protein tyrosine phosphorylation only in the flagellum, which corresponded to the physical localization of FER in human sperm. Our method provides an alternative strategy to study signaling markers associated with capacitation, such as protein tyrosine phosphorylation, in a fast and quantitative manner. None. This is an in vitro study performed under controlled conditions. Chemical inhibitors are not completely specific for the intended target; the possibility of side effects cannot be discarded. Our results demonstrate that the use of image-based flow cytometry is a very powerful tool to study sperm physiology. A large number of cells can be easily analyzed and information at the subcellular level can be obtained. As the segmentation process works with bright-field images, it can be extended to study expression of other proteins of interest using different antibodies or it can be used in living sperm to study intracellular parameters that can be followed using fluorescent dyes sensitive to the parameter of interest (e.g. pH, Ca2+). Therefore, this a versatile method that can be exploited to study several aspects of sperm physiology. This work was supported DGAPA (IN203116 to C. Treviño), Fronteras-CONACyT No. 71 and Eunice Kennedy Shriver National Institute of Child Health and Human Development NIH (RO1 HD38082) to P.E. Visconti and by a Lalor Foundation fellowship to M.G. Gervasi. A. Matamoros is a student of the Maestría en Ciencias Bioquímicas-UNAM program supported by CONACyT (416400) and DGAPA-UNAM. A. Moreno obtained a scholarship from Red MacroUniversidades and L. Giojalas obtained a schloarhip from CONICET and Universidad Nacional de Cordoba. The authors declare there are not conflicts of interest. © The Author 2017. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology. All rights reserved. For Permissions, please email:journals.permissions@oup.com
Lee, Alexandra J; Chang, Ivan; Burel, Julie G; Lindestam Arlehamn, Cecilia S; Mandava, Aishwarya; Weiskopf, Daniela; Peters, Bjoern; Sette, Alessandro; Scheuermann, Richard H; Qian, Yu
2018-04-17
Computational methods for identification of cell populations from polychromatic flow cytometry data are changing the paradigm of cytometry bioinformatics. Data clustering is the most common computational approach to unsupervised identification of cell populations from multidimensional cytometry data. However, interpretation of the identified data clusters is labor-intensive. Certain types of user-defined cell populations are also difficult to identify by fully automated data clustering analysis. Both are roadblocks before a cytometry lab can adopt the data clustering approach for cell population identification in routine use. We found that combining recursive data filtering and clustering with constraints converted from the user manual gating strategy can effectively address these two issues. We named this new approach DAFi: Directed Automated Filtering and Identification of cell populations. Design of DAFi preserves the data-driven characteristics of unsupervised clustering for identifying novel cell subsets, but also makes the results interpretable to experimental scientists through mapping and merging the multidimensional data clusters into the user-defined two-dimensional gating hierarchy. The recursive data filtering process in DAFi helped identify small data clusters which are otherwise difficult to resolve by a single run of the data clustering method due to the statistical interference of the irrelevant major clusters. Our experiment results showed that the proportions of the cell populations identified by DAFi, while being consistent with those by expert centralized manual gating, have smaller technical variances across samples than those from individual manual gating analysis and the nonrecursive data clustering analysis. Compared with manual gating segregation, DAFi-identified cell populations avoided the abrupt cut-offs on the boundaries. DAFi has been implemented to be used with multiple data clustering methods including K-means, FLOCK, FlowSOM, and the ClusterR package. For cell population identification, DAFi supports multiple options including clustering, bisecting, slope-based gating, and reversed filtering to meet various autogating needs from different scientific use cases. © 2018 International Society for Advancement of Cytometry. © 2018 International Society for Advancement of Cytometry.
De Spiegelaere, Ward; Philippé, Jan; Vervisch, Karen; Verhofstede, Chris; Malatinkova, Eva; Kiselinova, Maja; Trypsteen, Wim; Bonczkowski, Pawel; Vogelaers, Dirk; Callens, Steven; Ruelle, Jean; Kabeya, Kabamba; De Wit, Stephane; Van Acker, Petra; Van Sandt, Vicky; Emonds, Marie-Paule; Coucke, Paul; Sermijn, Erica; Vandekerckhove, Linos
2015-01-01
Abacavir is a nucleoside reverse transcriptase inhibitor used as part of combination antiretroviral therapy in HIV-1-infected patients. Because this drug can cause a hypersensitivity reaction that is correlated with the presence of the HLA-B*57:01 allotype, screening for the presence of HLA-B*57:01 is recommended before abacavir initiation. Different genetic assays have been developed for HLA-B*57:01 screening, each with specific sensitivity, turnaround time and assay costs. Here, a new real-time PCR (qPCR) based analysis is described and compared to sequence specific primer PCR with capillary electrophoresis (SSP PCR CE) on 149 patient-derived samples, using sequence specific oligonucleotide hybridization combined with high resolution SSP PCR as gold standard. In addition to these PCR based methods, a complementary approach was developed using flow cytometry with an HLA-B17 specific monoclonal antibody as a pre-screening assay to diminish the number of samples for genetic testing. All three assays had a maximum sensitivity of >99. However, differences in specificity were recorded, i.e. 84.3%, 97.2% and >99% for flow cytometry, qPCR and SSP PCR CE respectively. Our data indicate that the most specific and sensitive of the compared methods is the SSP PCR CE. Flow cytometry pre-screening can substantially decrease the number of genetic tests for HLA-B*57:01 typing in a clinical setting.
Minimal Residual Disease Evaluation in Childhood Acute Lymphoblastic Leukemia: An Economic Analysis
Gajic-Veljanoski, O.; Pham, B.; Pechlivanoglou, P.; Krahn, M.; Higgins, Caroline; Bielecki, Joanna
2016-01-01
Background Minimal residual disease (MRD) testing by higher performance techniques such as flow cytometry and polymerase chain reaction (PCR) can be used to detect the proportion of remaining leukemic cells in bone marrow or peripheral blood during and after the first phases of chemotherapy in children with acute lymphoblastic leukemia (ALL). The results of MRD testing are used to reclassify these patients and guide changes in treatment according to their future risk of relapse. We conducted a systematic review of the economic literature, cost-effectiveness analysis, and budget-impact analysis to ascertain the cost-effectiveness and economic impact of MRD testing by flow cytometry for management of childhood precursor B-cell ALL in Ontario. Methods A systematic literature search (1998–2014) identified studies that examined the incremental cost-effectiveness of MRD testing by either flow cytometry or PCR. We developed a lifetime state-transition (Markov) microsimulation model to quantify the cost-effectiveness of MRD testing followed by risk-directed therapy to no MRD testing and to estimate its marginal effect on health outcomes and on costs. Model input parameters were based on the literature, expert opinion, and data from the Pediatric Oncology Group of Ontario Networked Information System. Using predictions from our Markov model, we estimated the 1-year cost burden of MRD testing versus no testing and forecasted its economic impact over 3 and 5 years. Results In a base-case cost-effectiveness analysis, compared with no testing, MRD testing by flow cytometry at the end of induction and consolidation was associated with an increased discounted survival of 0.0958 quality-adjusted life-years (QALYs) and increased discounted costs of $4,180, yielding an incremental cost-effectiveness ratio (ICER) of $43,613/QALY gained. After accounting for parameter uncertainty, incremental cost-effectiveness of MRD testing was associated with an ICER of $50,249/QALY gained. In the budget-impact analysis, the 1-year cost expenditure for MRD testing by flow cytometry in newly diagnosed patients with precursor B-cell ALL was estimated at $340,760. We forecasted that the province would have to pay approximately $1.3 million over 3 years and $2.4 million over 5 years for MRD testing by flow cytometry in this population. Conclusions Compared with no testing, MRD testing by flow cytometry in newly diagnosed patients with precursor B-cell ALL represents good value for money at commonly used willingness-to-pay thresholds of $50,000/QALY and $100,000/QALY. PMID:27099644
NASA Astrophysics Data System (ADS)
Yang, Ping; Liu, Rongrong; Niu, Zhenyu; Suo, Yuanzhen; He, Hao; Wei, Xunbin
2015-03-01
Melanoma is a malignant tumor of melanocytes. Circulating melanoma cell has high light absorption due to melanin highly contained in melanoma cells. This property is employed for the detection of circulating melanoma cell by in vivo photoacoustic flow cytometry (PAFC). PAFC is based on photoacoustic effect. Compared to in vivo flow cytometry based on fluorescence, PAFC can employ high melanin content of melanoma cells as endogenous biomarkers to detect circulating melanoma cells in vivo. In our research, we developed in vitro experiments to prove the ability of PAFC system of detecting PA signals from melanoma cells. For in vivo experiments, we constructed a model of melanoma tumor bearing mice by inoculating highly metastatic murine melanoma cancer cells B16F10 with subcutaneous injection. PA signals were detected in the blood vessels of mouse ears in vivo. By counting circulating melanoma cells termly, we obtained the number variation of circulating melanoma cells as melanoma metastasized. Those results show that PAFC is a noninvasive and label-free method to detect melanoma metastases in blood or lymph circulation. Our PAFC system is an efficient tool to monitor melanoma metastases, cancer recurrence and therapeutic efficacy.
Kovács, Tamás; Békési, Gyöngyi; Fábián, Akos; Rákosy, Zsuzsa; Horváth, Gábor; Mátyus, László; Balázs, Margit; Jenei, Attila
2008-10-01
Rapid flow cytometric measurement of the frequency of aneuploid human sperms is in increasing demand but development of an exploitable method is hindered by difficulties of stoichiometric staining of sperm DNA. An aggressive decondensation protocol is needed after which cell integrity still remains intact. We used flow cytometry to examine the effect of lithium diiodosalicylate (LIS, chaotropic agent) on fluorescence intensity of propidium iodide-treated human spermatozoa from 10 normozoospermic men. When flow cytometric identification of diploid spermatozoa was achieved, validation was performed after sorting by three-color FISH. In contrast with the extremely variable histograms of nondecondensed sperms, consistent identification of haploid and diploid spermatozoa was possible if samples were decondensed with LIS prior to flow cytometry. A 76-fold enrichment of diploid sperms was observed in the sorted fractions by FISH. A significant correlation was found between the proportion of sorted cells and of diploid sperms by FISH. Application of LIS during the preparation of sperm for flow cytometry appears to ensure the stoichiometric staining of sperm DNA, making quantification of aneuploid sperm percentage possible. To our knowledge this is the first report in terms of separating spermatozoa with confirmedly abnormal chromosomal content. High correlation between the proportion of cells identified as having double DNA content by flow cytometry and diploid sperm by FISH allows rapid calculation of diploidy rate. Copyright 2008 International Society for Advancement of Cytometry.
Chan, Leo Li-Ying; Smith, Tim; Kumph, Kendra A; Kuksin, Dmitry; Kessel, Sarah; Déry, Olivier; Cribbes, Scott; Lai, Ning; Qiu, Jean
2016-10-01
To ensure cell-based assays are performed properly, both cell concentration and viability have to be determined so that the data can be normalized to generate meaningful and comparable results. Cell-based assays performed in immuno-oncology, toxicology, or bioprocessing research often require measuring of multiple samples and conditions, thus the current automated cell counter that uses single disposable counting slides is not practical for high-throughput screening assays. In the recent years, a plate-based image cytometry system has been developed for high-throughput biomolecular screening assays. In this work, we demonstrate a high-throughput AO/PI-based cell concentration and viability method using the Celigo image cytometer. First, we validate the method by comparing directly to Cellometer automated cell counter. Next, cell concentration dynamic range, viability dynamic range, and consistency are determined. The high-throughput AO/PI method described here allows for 96-well to 384-well plate samples to be analyzed in less than 7 min, which greatly reduces the time required for the single sample-based automated cell counter. In addition, this method can improve the efficiency for high-throughput screening assays, where multiple cell counts and viability measurements are needed prior to performing assays such as flow cytometry, ELISA, or simply plating cells for cell culture.
Carulli, Giovanni; Marini, Alessandra; Sammuri, Paola; Domenichini, Cristiana; Ottaviano, Virginia; Pacini, Simone; Petrini, Mario
2015-01-01
The identification of eosinophils by flow cytometry is difficult because most of the surface antigens expressed by eosinophils are shared with neutrophils. Some methods have been proposed, generally based on differential light scatter properties, enhanced autofluorescence, lack of CD16 or selective positivity of CD52. Such methods, however, show several limitations. In the present study we report a novel method based on the analysis of glycosylphosphatidylinositol (GPI)-linked molecules. The combination of CD157 and FLAER was used, since FLAER recognizes all GPI-linked molecules, while CD157 is absent on the membrane of eosinophils and expressed by neutrophils. Peripheral blood samples from normal subjects and patients with variable percentages of eosinophils (n = 31), and without any evidence for circulating immature myeloid cells, were stained with the combination of FLAER-Alexa Fluor and CD157-PE. A FascCanto II cytometer was used. Granulocytes were gated after CD33 staining and eosinophils were identified as CD157(-)/FLAER(+) events. Neutrophils were identified as CD157(+)/FLAER(+) events. The percentages of eosinophils detected by this method showed a very significant correlation both with automated counting and with manual counting (r = 0.981 and 0.989, respectively). Sorting assays were carried out by a S3 Cell Sorter: cytospins obtained from CD157(-)/FLAER(+) events consisted of 100% eosinophils, while samples from CD157(+)/FLAER(+) events were represented only by neutrophils. In conclusion, this method shows high sensitivity and specificity in order to distinguish eosinophils from neutrophils by flow cytometry. However, since CD157 is gradually up-regulated throughout bone marrow myeloid maturation, our method cannot be applied to cases characterized by immature myeloid cells.
Vollmer, T; Engemann, J; Kleesiek, K; Dreier, J
2011-06-01
Bacterial contamination is currently the major infectious hazard of platelet transfusion in developed countries. It has been demonstrated that a significant transfusion risk remains, in particular with older platelet concentrates (PCs). In 2009, the shelf life of PCs was therefore reduced in Germany to 4 days after the day of production according to Vote 38. The aim of the present study was the application and implementation of a recently developed flow cytometry-based rapid screening method (BactiFlow) for bacterial contamination at the end of PC shelf life as a routine in-process control. A total of 472 apheresis-derived PCs were tested using the BactiFlow flow cytometric assay to detect and count bacteria based on esterase activity in viable bacterial cells, while the BacT/Alert automated culture system served as the reference method. The automation potential of the flow cytometric assay was analysed by applying the semi-automated BactiFlow ALS system. An algorithm was developed for use in routine blood bank operations to extend the storage period of PCs. Two of the 472 apheresis PCs tested were positive in culture and identified as Propionibacterium species. One PC was positive for Staphylococcus aureus by both methods. All remaining specimens were tested negative by both methods. Our study demonstrates that routine bacterial testing of PCs was successfully implemented and the established algorithm proved efficient. The BactiFlow flow cytometric assay is the first rapid screening method which is suitable for a routine application combined with a high sensitivity. © 2011 The Authors. Transfusion Medicine © 2011 British Blood Transfusion Society.
Müller, Martin; Seidenberg, Ruth; Schuh, Sabine K; Exadaktylos, Aristomenis K; Schechter, Clyde B; Leichtle, Alexander B; Hautz, Wolf E
2018-01-01
Patients presenting with suspected urinary tract infection are common in every day emergency practice. Urine flow cytometry has replaced microscopic urine evaluation in many emergency departments, but interpretation of the results remains challenging. The aim of this study was to develop and validate tools that predict urine culture growth out of urine flow cytometry parameter. This retrospective study included all adult patients that presented in a large emergency department between January and July 2017 with a suspected urinary tract infection and had a urine flow cytometry as well as a urine culture obtained. The objective was to identify urine flow cytometry parameters that reliably predict urine culture growth and mixed flora growth. The data set was split into a training (70%) and a validation set (30%) and different decision-making approaches were developed and validated. Relevant urine culture growth (respectively mixed flora growth) was found in 40.2% (7.2% respectively) of the 613 patients included. The number of leukocytes and bacteria in flow cytometry were highly associated with urine culture growth, but mixed flora growth could not be sufficiently predicted from the urine flow cytometry parameters. A decision tree, predictive value figures, a nomogram, and a cut-off table to predict urine culture growth from bacteria and leukocyte count were developed, validated and compared. Urine flow cytometry parameters are insufficient to predict mixed flora growth. However, the prediction of urine culture growth based on bacteria and leukocyte count is highly accurate and the developed tools should be used as part of the decision-making process of ordering a urine culture or starting an antibiotic therapy if a urogenital infection is suspected.
Villanova, Federica; Di Meglio, Paola; Inokuma, Margaret; Aghaeepour, Nima; Perucha, Esperanza; Mollon, Jennifer; Nomura, Laurel; Hernandez-Fuentes, Maria; Cope, Andrew; Prevost, A Toby; Heck, Susanne; Maino, Vernon; Lord, Graham; Brinkman, Ryan R; Nestle, Frank O
2013-01-01
Discovery of novel immune biomarkers for monitoring of disease prognosis and response to therapy in immune-mediated inflammatory diseases is an important unmet clinical need. Here, we establish a novel framework for immunological biomarker discovery, comparing a conventional (liquid) flow cytometry platform (CFP) and a unique lyoplate-based flow cytometry platform (LFP) in combination with advanced computational data analysis. We demonstrate that LFP had higher sensitivity compared to CFP, with increased detection of cytokines (IFN-γ and IL-10) and activation markers (Foxp3 and CD25). Fluorescent intensity of cells stained with lyophilized antibodies was increased compared to cells stained with liquid antibodies. LFP, using a plate loader, allowed medium-throughput processing of samples with comparable intra- and inter-assay variability between platforms. Automated computational analysis identified novel immunophenotypes that were not detected with manual analysis. Our results establish a new flow cytometry platform for standardized and rapid immunological biomarker discovery with wide application to immune-mediated diseases.
Villanova, Federica; Di Meglio, Paola; Inokuma, Margaret; Aghaeepour, Nima; Perucha, Esperanza; Mollon, Jennifer; Nomura, Laurel; Hernandez-Fuentes, Maria; Cope, Andrew; Prevost, A. Toby; Heck, Susanne; Maino, Vernon; Lord, Graham; Brinkman, Ryan R.; Nestle, Frank O.
2013-01-01
Discovery of novel immune biomarkers for monitoring of disease prognosis and response to therapy in immune-mediated inflammatory diseases is an important unmet clinical need. Here, we establish a novel framework for immunological biomarker discovery, comparing a conventional (liquid) flow cytometry platform (CFP) and a unique lyoplate-based flow cytometry platform (LFP) in combination with advanced computational data analysis. We demonstrate that LFP had higher sensitivity compared to CFP, with increased detection of cytokines (IFN-γ and IL-10) and activation markers (Foxp3 and CD25). Fluorescent intensity of cells stained with lyophilized antibodies was increased compared to cells stained with liquid antibodies. LFP, using a plate loader, allowed medium-throughput processing of samples with comparable intra- and inter-assay variability between platforms. Automated computational analysis identified novel immunophenotypes that were not detected with manual analysis. Our results establish a new flow cytometry platform for standardized and rapid immunological biomarker discovery with wide application to immune-mediated diseases. PMID:23843942
NASA Technical Reports Server (NTRS)
Hymer, W. C.; Grindeland, R.; Hayes, C.; Lanham, J. W.; Cleveland, C.; Todd, P.; Morrison, Dennis R.
1988-01-01
The cell separation techniques of velocity sedimentation, flow cytometry and continuous flow electrophoresis were used to obtain enriched populations of growth hormone (GH) cells. The goal was to isolate a GH cell subpopulation which releases GH molecules which are very high in biological activity, it was important to use a method which was effective in processing large numbers of cells over a short time span. The techniques based on sedimentation are limited by cell density overlaps and streaming. While flow cytometry is useful in the analytical mode for objectively establishing cell purity, the numbers of cells which can be processed in the sort mode are so small as to make this approach ineffective in terms of the long term goals. It was shown that continuous flow electrophoresis systems (CFES) can separate GH cells from other cell types on the basis of differences in surface charge. The bioreactive producers appear to be more electrophoretically mobile than the low producers. Current ground based CFES efforts are hampered by cell clumping in low ionic strength buffers and poor cell recoveries from the CFES device.
NASA Technical Reports Server (NTRS)
Telford, W. G.; Cox, W. G.; Stiner, D.; Singer, V. L.; Doty, S. B.
1999-01-01
BACKGROUND: The alkaline phosphatase (AP) substrate 2-(5'-chloro-2'-phosphoryloxyphenyl)-6-chloro-4-(3H)-quinazolinone (ELF((R))-97 for enzyme-labeled fluorescence) has been found useful for the histochemical detection of endogenous AP activity and AP-tagged proteins and oligonucleotide probes. In this study, we evaluated its effectiveness at detecting endogenous AP activity by flow cytometry. METHODS: The ELF-97 phosphatase substrate was used to detect endogenous AP activity in UMR-106 rat osteosarcoma cells and primary cultures of chick chondrocytes. Cells were labeled with the ELF-97 reagent and analyzed by flow cytometry using an argon ultraviolet (UV) laser. For comparison purposes, cells were also assayed for AP using a Fast Red Violet LB azo dye assay previously described for use in detecting AP activity by flow cytometry. RESULTS: The ELF-97 phosphatase substrate effectively detected endogenous AP activity in UMR-106 cells, with over 95% of the resulting fluorescent signal resulting from AP-specific activity (as determined by levamisole inhibition of AP activity). In contrast, less than 70% of the fluorescent signal from the Fast Red Violet LB (FRV) assay was AP-dependent, reflecting the high intrinsic fluorescence of the unreacted components. The ELF-97 phosphatase assay was also able to detect very low AP activity in chick chondrocytes that was undetectable by the azo dye method. CONCLUSIONS: The ELF-97 phosphatase assay was able to detect endogenous AP activity in fixed mammalian and avian cells by flow cytometry with superior sensitivity to previously described assays. This work also shows the applicability of ELF-97 to flow cytometry, supplementing its previously demonstrated histochemical applications. Copyright 1999 Wiley-Liss, Inc.
Monoclonal Antibody L1Mab-13 Detected Human PD-L1 in Lung Cancers.
Yamada, Shinji; Itai, Shunsuke; Nakamura, Takuro; Yanaka, Miyuki; Chang, Yao-Wen; Suzuki, Hiroyoshi; Kaneko, Mika K; Kato, Yukinari
2018-04-01
Programmed cell death ligand-1 (PD-L1) is a type I transmembrane glycoprotein expressed on antigen-presenting cells. It is also expressed in several tumor cells such as melanoma and lung cancer cells. A strong correlation has been reported between human PD-L1 (hPD-L1) expression in tumor cells and negative prognosis in cancer patients. Here, a novel anti-hPD-L1 monoclonal antibody (mAb) L 1 Mab-13 (IgG 1 , kappa) was produced using a cell-based immunization and screening (CBIS) method. We investigated hPD-L1 expression in lung cancer using flow cytometry, Western blot, and immunohistochemical analyses. L 1 Mab-13 specifically reacted hPD-L1 of hPD-L1-overexpressed Chinese hamster ovary (CHO)-K1 cells and endogenous hPD-L1 of KMST-6 (human fibroblast) in flow cytometry and Western blot. Furthermore, L 1 Mab-13 reacted with lung cancer cell lines (EBC-1, Lu65, and Lu99) in flow cytometry and stained lung cancer tissues in a membrane-staining pattern in immunohistochemical analysis. These results indicate that a novel anti-hPD-L1 mAb, L 1 Mab-13, is very useful for detecting hPD-L1 of lung cancers in flow cytometry, Western blot, and immunohistochemical analyses.
Forment, Josep V.; Jackson, Stephen P.
2016-01-01
Protein accumulation on chromatin has traditionally been studied using immunofluorescence microscopy or biochemical cellular fractionation followed by western immunoblot analysis. As a way to improve the reproducibility of this kind of analysis, make it easier to quantify and allow a stream-lined application in high-throughput screens, we recently combined a classical immunofluorescence microscopy detection technique with flow cytometry1. In addition to the features described above, and by combining it with detection of both DNA content and DNA replication, this method allows unequivocal and direct assignment of cell-cycle distribution of protein association to chromatin without the need for cell culture synchronization. Furthermore, it is relatively quick (no more than a working day from sample collection to quantification), requires less starting material compared to standard biochemical fractionation methods and overcomes the need for flat, adherent cell types that are required for immunofluorescence microscopy. PMID:26226461
Routine detection of Epstein-Barr virus specific T-cells in the peripheral blood by flow cytometry
NASA Technical Reports Server (NTRS)
Crucian, B. E.; Stowe, R. P.; Pierson, D. L.; Sams, C. F.
2001-01-01
The ability to detect cytomegalovirus-specific T-cells (CD4(+)) in the peripheral blood by flow cytometry has been recently described by Picker et al. In this method, cells are incubated with viral antigen and responding (cytokine producing) T-cells are then identified by flow cytometry. To date, this technique has not been reliably used to detect Epstein-Barr virus (EBV)-specific T-cells primarily due to the superantigen/mitogenic properties of the virus which non-specifically activate T-cells. By modifying culture conditions under which the antigens are presented, we have overcome this limitation and developed an assay to detect and quantitate EBV-specific T-cells. The detection of cytokine producing T-cells by flow cytometry requires an extremely strong signal (such as culture in the presence of PMA and ionomycin). Our data indicate that in modified culture conditions (early removal of viral antigen) the non-specific activation of T-cells by EBV is reduced, but antigen presentation will continue uninhibited. Using this method, EBV-specific T-cells may be legitimately detected using flow cytometry. No reduction in the numbers of antigen-specific T-cells was observed by the early removal of target antigen when verified using cytomegalovirus antigen (a virus with no non-specific T-cell activation properties). In EBV-seropositive individuals, the phenotype of the EBV-specific cytokine producing T-cells was evaluated using four-color flow cytometry and found to be CD45(+), CD3(+), CD4(+), CD45RA(-), CD69(+), CD25(-). This phenotype indicates the stimulation of circulating previously unactivated memory T-cells. No cytokine production was observed in CD4(+) T-cells from EBV-seronegative individuals, confirming the specificity of this assay. In addition, the use of four color cytometry (CD45, CD3, CD69, IFNgamma/IL-2) allows the total quantitative assessment of EBV-specific T-cells while monitoring the interference of EBV non-specific mitogenic activity. This method may have significant utility for the monitoring of the immune response to latent virus infection/reactivation.
Guérin, Frédéric; Arnaiz, Olivier; Boggetto, Nicole; Denby Wilkes, Cyril; Meyer, Eric; Sperling, Linda; Duharcourt, Sandra
2017-04-26
DNA elimination is developmentally programmed in a wide variety of eukaryotes, including unicellular ciliates, and leads to the generation of distinct germline and somatic genomes. The ciliate Paramecium tetraurelia harbors two types of nuclei with different functions and genome structures. The transcriptionally inactive micronucleus contains the complete germline genome, while the somatic macronucleus contains a reduced genome streamlined for gene expression. During development of the somatic macronucleus, the germline genome undergoes massive and reproducible DNA elimination events. Availability of both the somatic and germline genomes is essential to examine the genome changes that occur during programmed DNA elimination and ultimately decipher the mechanisms underlying the specific removal of germline-limited sequences. We developed a novel experimental approach that uses flow cell imaging and flow cytometry to sort subpopulations of nuclei to high purity. We sorted vegetative micronuclei and macronuclei during development of P. tetraurelia. We validated the method by flow cell imaging and by high throughput DNA sequencing. Our work establishes the proof of principle that developing somatic macronuclei can be sorted from a complex biological sample to high purity based on their size, shape and DNA content. This method enabled us to sequence, for the first time, the germline DNA from pure micronuclei and to identify novel transposable elements. Sequencing the germline DNA confirms that the Pgm domesticated transposase is required for the excision of all ~45,000 Internal Eliminated Sequences. Comparison of the germline DNA and unrearranged DNA obtained from PGM-silenced cells reveals that the latter does not provide a faithful representation of the germline genome. We developed a flow cytometry-based method to purify P. tetraurelia nuclei to high purity and provided quality control with flow cell imaging and high throughput DNA sequencing. We identified 61 germline transposable elements including the first Paramecium retrotransposons. This approach paves the way to sequence the germline genomes of P. aurelia sibling species for future comparative genomic studies.
Stochastic Individual-Based Modeling of Bacterial Growth and Division Using Flow Cytometry.
García, Míriam R; Vázquez, José A; Teixeira, Isabel G; Alonso, Antonio A
2017-01-01
A realistic description of the variability in bacterial growth and division is critical to produce reliable predictions of safety risks along the food chain. Individual-based modeling of bacteria provides the theoretical framework to deal with this variability, but it requires information about the individual behavior of bacteria inside populations. In this work, we overcome this problem by estimating the individual behavior of bacteria from population statistics obtained with flow cytometry. For this objective, a stochastic individual-based modeling framework is defined based on standard assumptions during division and exponential growth. The unknown single-cell parameters required for running the individual-based modeling simulations, such as cell size growth rate, are estimated from the flow cytometry data. Instead of using directly the individual-based model, we make use of a modified Fokker-Plank equation. This only equation simulates the population statistics in function of the unknown single-cell parameters. We test the validity of the approach by modeling the growth and division of Pediococcus acidilactici within the exponential phase. Estimations reveal the statistics of cell growth and division using only data from flow cytometry at a given time. From the relationship between the mother and daughter volumes, we also predict that P. acidilactici divide into two successive parallel planes.
flowVS: channel-specific variance stabilization in flow cytometry.
Azad, Ariful; Rajwa, Bartek; Pothen, Alex
2016-07-28
Comparing phenotypes of heterogeneous cell populations from multiple biological conditions is at the heart of scientific discovery based on flow cytometry (FC). When the biological signal is measured by the average expression of a biomarker, standard statistical methods require that variance be approximately stabilized in populations to be compared. Since the mean and variance of a cell population are often correlated in fluorescence-based FC measurements, a preprocessing step is needed to stabilize the within-population variances. We present a variance-stabilization algorithm, called flowVS, that removes the mean-variance correlations from cell populations identified in each fluorescence channel. flowVS transforms each channel from all samples of a data set by the inverse hyperbolic sine (asinh) transformation. For each channel, the parameters of the transformation are optimally selected by Bartlett's likelihood-ratio test so that the populations attain homogeneous variances. The optimum parameters are then used to transform the corresponding channels in every sample. flowVS is therefore an explicit variance-stabilization method that stabilizes within-population variances in each channel by evaluating the homoskedasticity of clusters with a likelihood-ratio test. With two publicly available datasets, we show that flowVS removes the mean-variance dependence from raw FC data and makes the within-population variance relatively homogeneous. We demonstrate that alternative transformation techniques such as flowTrans, flowScape, logicle, and FCSTrans might not stabilize variance. Besides flow cytometry, flowVS can also be applied to stabilize variance in microarray data. With a publicly available data set we demonstrate that flowVS performs as well as the VSN software, a state-of-the-art approach developed for microarrays. The homogeneity of variance in cell populations across FC samples is desirable when extracting features uniformly and comparing cell populations with different levels of marker expressions. The newly developed flowVS algorithm solves the variance-stabilization problem in FC and microarrays by optimally transforming data with the help of Bartlett's likelihood-ratio test. On two publicly available FC datasets, flowVS stabilizes within-population variances more evenly than the available transformation and normalization techniques. flowVS-based variance stabilization can help in performing comparison and alignment of phenotypically identical cell populations across different samples. flowVS and the datasets used in this paper are publicly available in Bioconductor.
Doucette, Jaimee; Zhao, Ziyan; Geyer, Rory J; Barra, Melanie M; Balunas, Marcy J; Zweifach, Adam
2016-07-01
Genetically encoded sensors based on intramolecular FRET between CFP and YFP are used extensively in cell biology research. Flow cytometry has been shown to offer a means to measure CFP-YFP FRET; we suspected it would provide a unique way to conduct multiplexed measurements from cells expressing different FRET sensors, which is difficult to do with microscopy, and that this could be used for screening. We confirmed that flow cytometry accurately measures FRET signals using cells transiently transfected with an ERK activity reporter, comparing responses measured with imaging and cytometry. We created polyclonal long-term transfectant lines, each expressing a different intramolecular FRET sensor, and devised a way to bar-code four distinct populations of cells. We demonstrated the feasibility of multiplexed measurements and determined that robust multiplexed measurements can be conducted in plate format. To validate the suitability of the method for screening, we measured responses from a plate of bacterial extracts that in unrelated experiments we had determined contained the protein kinase C (PKC)-activating compound teleocidin A-1. The multiplexed assay correctly identifying the teleocidin A-1-containing well. We propose that multiplexed cytometric FRET measurements will be useful for analyzing cellular function and for screening compound collections. © 2016 Society for Laboratory Automation and Screening.
One-dimensional acoustic standing waves in rectangular channels for flow cytometry.
Austin Suthanthiraraj, Pearlson P; Piyasena, Menake E; Woods, Travis A; Naivar, Mark A; Lόpez, Gabriel P; Graves, Steven W
2012-07-01
Flow cytometry has become a powerful analytical tool for applications ranging from blood diagnostics to high throughput screening of molecular assemblies on microsphere arrays. However, instrument size, expense, throughput, and consumable use limit its use in resource poor areas of the world, as a component in environmental monitoring, and for detection of very rare cell populations. For these reasons, new technologies to improve the size and cost-to-performance ratio of flow cytometry are required. One such technology is the use of acoustic standing waves that efficiently concentrate cells and particles to the center of flow channels for analysis. The simplest form of this method uses one-dimensional acoustic standing waves to focus particles in rectangular channels. We have developed one-dimensional acoustic focusing flow channels that can be fabricated in simple capillary devices or easily microfabricated using photolithography and deep reactive ion etching. Image and video analysis demonstrates that these channels precisely focus single flowing streams of particles and cells for traditional flow cytometry analysis. Additionally, use of standing waves with increasing harmonics and in parallel microfabricated channels is shown to effectively create many parallel focused streams. Furthermore, we present the fabrication of an inexpensive optical platform for flow cytometry in rectangular channels and use of the system to provide precise analysis. The simplicity and low-cost of the acoustic focusing devices developed here promise to be effective for flow cytometers that have reduced size, cost, and consumable use. Finally, the straightforward path to parallel flow streams using one-dimensional multinode acoustic focusing, indicates that simple acoustic focusing in rectangular channels may also have a prominent role in high-throughput flow cytometry. Copyright © 2012 Elsevier Inc. All rights reserved.
FuGEFlow: data model and markup language for flow cytometry
Qian, Yu; Tchuvatkina, Olga; Spidlen, Josef; Wilkinson, Peter; Gasparetto, Maura; Jones, Andrew R; Manion, Frank J; Scheuermann, Richard H; Sekaly, Rafick-Pierre; Brinkman, Ryan R
2009-01-01
Background Flow cytometry technology is widely used in both health care and research. The rapid expansion of flow cytometry applications has outpaced the development of data storage and analysis tools. Collaborative efforts being taken to eliminate this gap include building common vocabularies and ontologies, designing generic data models, and defining data exchange formats. The Minimum Information about a Flow Cytometry Experiment (MIFlowCyt) standard was recently adopted by the International Society for Advancement of Cytometry. This standard guides researchers on the information that should be included in peer reviewed publications, but it is insufficient for data exchange and integration between computational systems. The Functional Genomics Experiment (FuGE) formalizes common aspects of comprehensive and high throughput experiments across different biological technologies. We have extended FuGE object model to accommodate flow cytometry data and metadata. Methods We used the MagicDraw modelling tool to design a UML model (Flow-OM) according to the FuGE extension guidelines and the AndroMDA toolkit to transform the model to a markup language (Flow-ML). We mapped each MIFlowCyt term to either an existing FuGE class or to a new FuGEFlow class. The development environment was validated by comparing the official FuGE XSD to the schema we generated from the FuGE object model using our configuration. After the Flow-OM model was completed, the final version of the Flow-ML was generated and validated against an example MIFlowCyt compliant experiment description. Results The extension of FuGE for flow cytometry has resulted in a generic FuGE-compliant data model (FuGEFlow), which accommodates and links together all information required by MIFlowCyt. The FuGEFlow model can be used to build software and databases using FuGE software toolkits to facilitate automated exchange and manipulation of potentially large flow cytometry experimental data sets. Additional project documentation, including reusable design patterns and a guide for setting up a development environment, was contributed back to the FuGE project. Conclusion We have shown that an extension of FuGE can be used to transform minimum information requirements in natural language to markup language in XML. Extending FuGE required significant effort, but in our experiences the benefits outweighed the costs. The FuGEFlow is expected to play a central role in describing flow cytometry experiments and ultimately facilitating data exchange including public flow cytometry repositories currently under development. PMID:19531228
Immune Response to Mycobacterial Infection: Lessons from Flow Cytometry
Rovina, Nikoletta; Panagiotou, Marios; Koulouris, Nikolaos G.
2013-01-01
Detecting and treating active and latent tuberculosis are pivotal elements for effective infection control; yet, due to their significant inherent limitations, the diagnostic means for these two stages of tuberculosis (TB) to date remain suboptimal. This paper reviews the current diagnostic tools for mycobacterial infection and focuses on the application of flow cytometry as a promising method for rapid and reliable diagnosis of mycobacterial infection as well as discrimination between active and latent TB: it summarizes diagnostic biomarkers distinguishing the two states of infection and also features of the distinct immune response against Mycobacterium tuberculosis (Mtb) at certain stages of infection as revealed by flow cytometry to date. PMID:24376464
Immune response to mycobacterial infection: lessons from flow cytometry.
Rovina, Nikoletta; Panagiotou, Marios; Pontikis, Konstantinos; Kyriakopoulou, Magdalini; Koulouris, Nikolaos G; Koutsoukou, Antonia
2013-01-01
Detecting and treating active and latent tuberculosis are pivotal elements for effective infection control; yet, due to their significant inherent limitations, the diagnostic means for these two stages of tuberculosis (TB) to date remain suboptimal. This paper reviews the current diagnostic tools for mycobacterial infection and focuses on the application of flow cytometry as a promising method for rapid and reliable diagnosis of mycobacterial infection as well as discrimination between active and latent TB: it summarizes diagnostic biomarkers distinguishing the two states of infection and also features of the distinct immune response against Mycobacterium tuberculosis (Mtb) at certain stages of infection as revealed by flow cytometry to date.
Jarzembowski, T; Wiśniewska, K; Józwik, A; Bryl, E; Witkowski, J
2008-08-01
We studied the usefulness of flow cytometry for detection of penicillin resistance in E. faecalis and S. aureus by direct binding of commercially available fluorescent penicillin, Bocillin FL, to cells obtained from culture. There were significantly lower percentages of fluorescent cells and median and mean fluorescence values per particle in penicillin-resistant than in penicillin-sensitive strains of both species observed. The method allows rapid detection of penicillin resistance in S. aureus and E. faecalis. The results encourage further investigations on the detection of antibiotic resistance in bacteria using flow cytometry.
Gregory, T Ryan; Nathwani, Paula; Bonnett, Tiffany R; Huber, Dezene P W
2013-09-01
A study was undertaken to evaluate both a pre-existing method and a newly proposed approach for the estimation of nuclear genome sizes in arthropods. First, concerns regarding the reliability of the well-established method of flow cytometry relating to impacts of rearing conditions on genome size estimates were examined. Contrary to previous reports, a more carefully controlled test found negligible environmental effects on genome size estimates in the fly Drosophila melanogaster. Second, a more recently touted method based on quantitative real-time PCR (qPCR) was examined in terms of ease of use, efficiency, and (most importantly) accuracy using four test species: the flies Drosophila melanogaster and Musca domestica and the beetles Tribolium castaneum and Dendroctonus ponderosa. The results of this analysis demonstrated that qPCR has the tendency to produce substantially different genome size estimates from other established techniques while also being far less efficient than existing methods.
Multivariate data analysis methods for the interpretation of microbial flow cytometric data.
Davey, Hazel M; Davey, Christopher L
2011-01-01
Flow cytometry is an important technique in cell biology and immunology and has been applied by many groups to the analysis of microorganisms. This has been made possible by developments in hardware that is now sensitive enough to be used routinely for analysis of microbes. However, in contrast to advances in the technology that underpin flow cytometry, there has not been concomitant progress in the software tools required to analyse, display and disseminate the data and manual analysis, of individual samples remains a limiting aspect of the technology. We present two new data sets that illustrate common applications of flow cytometry in microbiology and demonstrate the application of manual data analysis, automated visualisation (including the first description of a new piece of software we are developing to facilitate this), genetic programming, principal components analysis and artificial neural nets to these data. The data analysis methods described here are equally applicable to flow cytometric applications with other cell types.
Parks, David R; Roederer, Mario; Moore, Wayne A
2006-06-01
In immunofluorescence measurements and most other flow cytometry applications, fluorescence signals of interest can range down to essentially zero. After fluorescence compensation, some cell populations will have low means and include events with negative data values. Logarithmic presentation has been very useful in providing informative displays of wide-ranging flow cytometry data, but it fails to adequately display cell populations with low means and high variances and, in particular, offers no way to include negative data values. This has led to a great deal of difficulty in interpreting and understanding flow cytometry data, has often resulted in incorrect delineation of cell populations, and has led many people to question the correctness of compensation computations that were, in fact, correct. We identified a set of criteria for creating data visualization methods that accommodate the scaling difficulties presented by flow cytometry data. On the basis of these, we developed a new data visualization method that provides important advantages over linear or logarithmic scaling for display of flow cytometry data, a scaling we refer to as "Logicle" scaling. Logicle functions represent a particular generalization of the hyperbolic sine function with one more adjustable parameter than linear or logarithmic functions. Finally, we developed methods for objectively and automatically selecting an appropriate value for this parameter. The Logicle display method provides more complete, appropriate, and readily interpretable representations of data that includes populations with low-to-zero means, including distributions resulting from fluorescence compensation procedures, than can be produced using either logarithmic or linear displays. The method includes a specific algorithm for evaluating actual data distributions and deriving parameters of the Logicle scaling function appropriate for optimal display of that data. It is critical to note that Logicle visualization does not change the data values or the descriptive statistics computed from them. Copyright 2006 International Society for Analytical Cytology.
DNA Detection by Flow Cytometry using PNA-Modified Metal-Organic Framework Particles.
Mejia-Ariza, Raquel; Rosselli, Jessica; Breukers, Christian; Manicardi, Alex; Terstappen, Leon W M M; Corradini, Roberto; Huskens, Jurriaan
2017-03-23
A DNA-sensing platform is developed by exploiting the easy surface functionalization of metal-organic framework (MOF) particles and their highly parallelized fluorescence detection by flow cytometry. Two strategies were employed to functionalize the surface of MIL-88A, using either covalent or non-covalent interactions, resulting in alkyne-modified and biotin-modified MIL-88A, respectively. Covalent surface coupling of an azide-dye and the alkyne-MIL-88A was achieved by means of a click reaction. Non-covalent streptavidin-biotin interactions were employed to link biotin-PNA to biotin-MIL-88A particles mediated by streptavidin. Characterization by confocal imaging and flow cytometry demonstrated that DNA can be bound selectively to the MOF surface. Flow cytometry provided quantitative data of the interaction with DNA. Making use of the large numbers of particles that can be simultaneously processed by flow cytometry, this MOF platform was able to discriminate between fully complementary, single-base mismatched, and randomized DNA targets. © 2017 The Authors. Published by Wiley-VCH Verlag GmbH & Co. KGaA.
In vivo flow cytometry of circulating clots using negative photothermal and photoacoustic contrasts.
Galanzha, Ekaterina I; Sarimollaoglu, Mustafa; Nedosekin, Dmitry A; Keyrouz, Salah G; Mehta, Jawahar L; Zharov, Vladimir P
2011-10-01
Conventional photothermal (PT) and photoacousic (PA) imaging, spectroscopy, and cytometry are preferentially based on positive PT/PA effects, when signals are above background. Here, we introduce PT/PA technique based on detection of negative signals below background. Among various new applications, we propose label-free in vivo flow cytometry of circulating clots. No method has been developed for the early detection of clots of different compositions as a source of thromboembolism including ischemia at strokes and myocardial infarction. When a low-absorbing, platelet-rich clot passes a laser-irradiated vessel volume, a transient decrease in local absorption results in an ultrasharp negative PA hole in blood background. Using this phenomenon alone or in combination with positive contrasts, we demonstrated identification of white, red, and mixed clots on a mouse model of myocardial infarction and human blood. The concentration and size of clots were measured with threshold down to few clots in the entire circulation with size as low as 20 μm. This multiparameter diagnostic platform using portable personal high-speed flow cytometer with negative dynamic contrast mode has potential to real-time defining risk factors for cardiovascular diseases, and for prognosis and prevention of stroke or use clot count as a marker of therapy efficacy. Possibility for label-free detection of platelets, leukocytes, tumor cells or targeting themby negative PA probes (e.g., nonabsorbing beads or bubbles) is also highlighted. Copyright © 2011 International Society for Advancement of Cytometry.
Microfluidic Imaging Flow Cytometry by Asymmetric-detection Time-stretch Optical Microscopy (ATOM).
Tang, Anson H L; Lai, Queenie T K; Chung, Bob M F; Lee, Kelvin C M; Mok, Aaron T Y; Yip, G K; Shum, Anderson H C; Wong, Kenneth K Y; Tsia, Kevin K
2017-06-28
Scaling the number of measurable parameters, which allows for multidimensional data analysis and thus higher-confidence statistical results, has been the main trend in the advanced development of flow cytometry. Notably, adding high-resolution imaging capabilities allows for the complex morphological analysis of cellular/sub-cellular structures. This is not possible with standard flow cytometers. However, it is valuable for advancing our knowledge of cellular functions and can benefit life science research, clinical diagnostics, and environmental monitoring. Incorporating imaging capabilities into flow cytometry compromises the assay throughput, primarily due to the limitations on speed and sensitivity in the camera technologies. To overcome this speed or throughput challenge facing imaging flow cytometry while preserving the image quality, asymmetric-detection time-stretch optical microscopy (ATOM) has been demonstrated to enable high-contrast, single-cell imaging with sub-cellular resolution, at an imaging throughput as high as 100,000 cells/s. Based on the imaging concept of conventional time-stretch imaging, which relies on all-optical image encoding and retrieval through the use of ultrafast broadband laser pulses, ATOM further advances imaging performance by enhancing the image contrast of unlabeled/unstained cells. This is achieved by accessing the phase-gradient information of the cells, which is spectrally encoded into single-shot broadband pulses. Hence, ATOM is particularly advantageous in high-throughput measurements of single-cell morphology and texture - information indicative of cell types, states, and even functions. Ultimately, this could become a powerful imaging flow cytometry platform for the biophysical phenotyping of cells, complementing the current state-of-the-art biochemical-marker-based cellular assay. This work describes a protocol to establish the key modules of an ATOM system (from optical frontend to data processing and visualization backend), as well as the workflow of imaging flow cytometry based on ATOM, using human cells and micro-algae as the examples.
SCENERY: a web application for (causal) network reconstruction from cytometry data
Papoutsoglou, Georgios; Athineou, Giorgos; Lagani, Vincenzo; Xanthopoulos, Iordanis; Schmidt, Angelika; Éliás, Szabolcs; Tegnér, Jesper
2017-01-01
Abstract Flow and mass cytometry technologies can probe proteins as biological markers in thousands of individual cells simultaneously, providing unprecedented opportunities for reconstructing networks of protein interactions through machine learning algorithms. The network reconstruction (NR) problem has been well-studied by the machine learning community. However, the potentials of available methods remain largely unknown to the cytometry community, mainly due to their intrinsic complexity and the lack of comprehensive, powerful and easy-to-use NR software implementations specific for cytometry data. To bridge this gap, we present Single CEll NEtwork Reconstruction sYstem (SCENERY), a web server featuring several standard and advanced cytometry data analysis methods coupled with NR algorithms in a user-friendly, on-line environment. In SCENERY, users may upload their data and set their own study design. The server offers several data analysis options categorized into three classes of methods: data (pre)processing, statistical analysis and NR. The server also provides interactive visualization and download of results as ready-to-publish images or multimedia reports. Its core is modular and based on the widely-used and robust R platform allowing power users to extend its functionalities by submitting their own NR methods. SCENERY is available at scenery.csd.uoc.gr or http://mensxmachina.org/en/software/. PMID:28525568
Subirá, D; Górgolas, M; Castañón, S; Serrano, C; Román, A; Rivas, F; Tomás, J F
2005-01-01
Neurological disorders are common in HIV-infected patients. Central nervous system (CNS) lymphoma should always be considered because it is an important cause of morbidity and mortality. To investigate the clinical utility of flow cytometry immunophenotyping (FCI) in diagnosing or discarding leptomeningeal involvement in HIV-infected patients and to compare its sensitivity with that of conventional cytological methods. Fifty-six cerebrospinal fluid (CSF) samples from 29 HIV-infected patients were independently evaluated by flow cytometry and cytology. The description of an aberrant immunophenotype was the criterion used to define the malignant nature of any CSF cell population. FCI and cytology gave concordant results for 48 of the 56 CSF samples studied: 37 were negative for malignancy and 11 had evidence of CNS lymphoma. Discordant results were obtained for eight CSF samples, and the accuracy of the FCI findings could be demonstrated for four CSF samples described as positive for malignancy according to the FCI criteria. A high level of agreement was found between the results obtained using the two methods, but FCI gave at least 25% higher sensitivity than conventional cytomorphological methods for the detection of malignant cells. This advantage suggests that, in case of negative flow cytometry results, disorders other than non-Hodgkin's lymphoma should be strongly considered.
An optofluidic approach for gold nanoprobes based-cancer theranostics
NASA Astrophysics Data System (ADS)
Panwar, Nishtha; Song, Peiyi; Yang, Chengbin; Yong, Ken-Tye; Tjin, Swee Chuan
2017-02-01
Suppression of overexpressed gene mutations in cancer cells through RNA interference (RNAi) technique is a therapeutically effective modality for oncogene silencing. In general, transfection agent is needed for siRNA delivery. Also, it is a tedious and time consuming process to analyze the gene transfection using current conventional flow cytometry systems and commercially available transfection kits. Therefore, there are two urgent challenges that we need to address for understanding and real time monitoring the delivery of siRNA to cancer cells more effectively. One, nontoxic, biocompatible and stable non-viral transfection agents need to be developed and investigated for gene delivery in cancer cells. Two, new, portable optofluidic methods need to be engineered for determining the transfection efficiency of the nanoformulation in real time. First, we demonstrate the feasibility of using gold nanorods (AuNRs) as nanoprobes for the delivery of Interleukin-8 (IL-8) siRNA in a pancreatic cancer cell line- MiaPaCa-2. An optimum ratio of 10:1 for the AuNRs-siRNA nanoformulation required for efficient loading has been experimentally determined. Promising transfection rates (≈88%) of the nanoprobe-assisted gene delivery are quantified by flow cytometry and fluorescence imaging, which are higher than the commercial control, Oligofectamine. The excellent gene knockdown performance (over 81%) of the proposed model support in vivo trials for RNAi-based cancer theranostics. In addition to cancer theranostics, our nanoprobe combination can be also applied for disease outbreak monitoring like MERS. Second, we present an optical fiber-integrated microfluidic chip that utilizes simple hydrodynamic and optical setups for miniaturized on-chip flow cytometry. The chip provides a powerful and convenient tool to quantitatively determine the siRNA transfection into cancer cells without using bulky flow cytometer. These studies outline the role of AuNRs as potential non-viral gene delivery vehicles, and their suitability for microfluidics-based lab-on-chip flow cytometry applications.
Label-free counting of circulating cells by in vivo photoacoustic flow cytometry
NASA Astrophysics Data System (ADS)
Zhou, Quanyu; Yang, Ping; Wang, Qiyan; Pang, Kai; Zhou, Hui; He, Hao; Wei, Xunbin
2018-02-01
Melanoma, developing from melanocytes, is the most serious type of skin cancer. Circulating melanoma cells, the prognosis marker for metastasis, are present in the circulation at the early stage. Thus, quantitative detection of rare circulating melanoma cells is essential for monitoring tumor metastasis and prognosis evaluation. Compared with in vitro assays, in vivo flow cytometry is able to identify circulating tumor cells without drawing blood. Here, we built in vivo photoacoustic flow cytometry based on the high absorption coefficient of melanoma cells, which is applied to labelfree counting of circulating melanoma cells in tumor-bearing mice.
Critical Role of CD8 T Cells in Mediating Sex-Based Differences in a Murine Model of Lupus
2009-08-21
into female transfers (fF) mice that was reduced in CD8 depleted fF mice. Flow cytometry analysis showed increased numbers of splenic...splenocytes were first analyzed by flow cytometry for CD4 and CD8 T cells and F1 mice received either: a) unfractionated splenocytes (CD8 intactF1...using magnetic beads purchased from Invitrogen (Carlsbad, CA) according to the manufacturer’s instructions. Flow cytometry analysis before cell
Feng, Jingwen; Feng, Tong; Yang, Chengwen; Wang, Wei; Sa, Yu; Feng, Yuanming
2018-06-01
This study was to explore the feasibility of prediction and classification of cells in different stages of apoptosis with a stain-free method based on diffraction images and supervised machine learning. Apoptosis was induced in human chronic myelogenous leukemia K562 cells by cis-platinum (DDP). A newly developed technique of polarization diffraction imaging flow cytometry (p-DIFC) was performed to acquire diffraction images of the cells in three different statuses (viable, early apoptotic and late apoptotic/necrotic) after cell separation through fluorescence activated cell sorting with Annexin V-PE and SYTOX® Green double staining. The texture features of the diffraction images were extracted with in-house software based on the Gray-level co-occurrence matrix algorithm to generate datasets for cell classification with supervised machine learning method. Therefore, this new method has been verified in hydrogen peroxide induced apoptosis model of HL-60. Results show that accuracy of higher than 90% was achieved respectively in independent test datasets from each cell type based on logistic regression with ridge estimators, which indicated that p-DIFC system has a great potential in predicting and classifying cells in different stages of apoptosis.
Massicotte, Richard; Mafu, Akier A.; Ahmad, Darakhshan; Deshaies, Francis; Pichette, Gilbert; Belhumeur, Pierre
2017-01-01
The present study was undertaken to compare the use of flow cytometry (FCM) and traditional culture methods for efficacy assessment of six disinfectants used in Quebec hospitals including: two quaternary ammonium-based, two activated hydrogen peroxide-based, one phenol-based, and one sodium hypochlorite-based. Four nosocomial bacterial species, Escherichia coli, Staphylococcus aureus, Pseudomonas aeruginosa, and Vancomycin-resistant Enterococci faecalis, were exposed to minimum lethal concentrations (MLCs) and sublethal concentrations (1/2 MLCs) of disinfectants under study. The results showed a strong correlation between the two techniques for the presence of dead and live cell populations, as well as, evidence of injured populations with the FCM. The only exception was observed with sodium hypochlorite at higher concentrations where fluorescence was diminished and underestimating dead cell population. The results also showed that FCM can replace traditional microbiological methods to study disinfectant efficacy on bacteria. Furthermore, FCM profiles for E. coli and E. faecalis cells exposed to sublethal concentrations exhibited distinct populations of injured cells, opening a new aspect for future research and investigation to elucidate the role of injured, cultural/noncuturable/resuscitable cell populations in infection control. PMID:28217115
Nolan, John P.; Mandy, Francis
2008-01-01
While the term flow cytometry refers to the measurement of cells, the approach of making sensitive multiparameter optical measurements in a flowing sample stream is a very general analytical approach. The past few years have seen an explosion in the application of flow cytometry technology for molecular analysis and measurements using micro-particles as solid supports. While microsphere-based molecular analyses using flow cytometry date back three decades, the need for highly parallel quantitative molecular measurements that has arisen from various genomic and proteomic advances has driven the development in particle encoding technology to enable highly multiplexed assays. Multiplexed particle-based immunoassays are now common place, and new assays to study genes, protein function, and molecular assembly. Numerous efforts are underway to extend the multiplexing capabilities of microparticle-based assays through new approaches to particle encoding and analyte reporting. The impact of these developments will be seen in the basic research and clinical laboratories, as well as in drug development. PMID:16604537
Zeidler-Erdely, Patti C.; Antonini, James M.; Meighan, Terence G.; Young, Shih-Houng; Eye, Tracy J.; Hammer, Mary Ann; Erdely, Aaron
2016-01-01
Pulmonary toxicity studies often use bronchoalveolar lavage (BAL) to investigate potential adverse lung responses to a particulate exposure. The BAL cellular fraction is counted, using automated (i.e. Coulter Counter®), flow cytometry or manual (i.e. hemocytometer) methods, to determine inflammatory cell influx. The goal of the study was to compare the different counting methods to determine which is optimal for examining BAL cell influx after exposure by inhalation or intratracheal instillation (ITI) to different particles with varying inherent pulmonary toxicities in both rat and mouse models. General findings indicate that total BAL cell counts using the automated and manual methods tended to agree after inhalation or ITI exposure to particle samples that are relatively nontoxic or at later time points after exposure to a pneumotoxic particle when the response resolves. However, when the initial lung inflammation and cytotoxicity was high after exposure to a pneumotoxic particle, significant differences were observed when comparing cell counts from the automated, flow cytometry and manual methods. When using total BAL cell count for differential calculations from the automated method, depending on the cell diameter size range cutoff, the data suggest that the number of lung polymorphonuclear leukocytes (PMN) varies. Importantly, the automated counts, regardless of the size cutoff, still indicated a greater number of total lung PMN when compared with the manual method, which agreed more closely with flow cytometry. The results suggest that either the manual method or flow cytometry would be better suited for BAL studies where cytotoxicity is an unknown variable. PMID:27251196
Zeidler-Erdely, Patti C; Antonini, James M; Meighan, Terence G; Young, Shih-Houng; Eye, Tracy J; Hammer, Mary Ann; Erdely, Aaron
2016-08-01
Pulmonary toxicity studies often use bronchoalveolar lavage (BAL) to investigate potential adverse lung responses to a particulate exposure. The BAL cellular fraction is counted, using automated (i.e. Coulter Counter®), flow cytometry or manual (i.e. hemocytometer) methods, to determine inflammatory cell influx. The goal of the study was to compare the different counting methods to determine which is optimal for examining BAL cell influx after exposure by inhalation or intratracheal instillation (ITI) to different particles with varying inherent pulmonary toxicities in both rat and mouse models. General findings indicate that total BAL cell counts using the automated and manual methods tended to agree after inhalation or ITI exposure to particle samples that are relatively nontoxic or at later time points after exposure to a pneumotoxic particle when the response resolves. However, when the initial lung inflammation and cytotoxicity was high after exposure to a pneumotoxic particle, significant differences were observed when comparing cell counts from the automated, flow cytometry and manual methods. When using total BAL cell count for differential calculations from the automated method, depending on the cell diameter size range cutoff, the data suggest that the number of lung polymorphonuclear leukocytes (PMN) varies. Importantly, the automated counts, regardless of the size cutoff, still indicated a greater number of total lung PMN when compared with the manual method, which agreed more closely with flow cytometry. The results suggest that either the manual method or flow cytometry would be better suited for BAL studies where cytotoxicity is an unknown variable.
Konokhova, Anastasiya I; Chernova, Darya N; Moskalensky, Alexander E; Strokotov, Dmitry I; Yurkin, Maxim A; Chernyshev, Andrei V; Maltsev, Valeri P
2016-02-01
Importance of microparticles (MPs), also regarded as extracellular vesicles, in many physiological processes and clinical conditions motivates one to use the most informative and precise methods for their characterization. Methods based on individual particle analysis provide statistically reliable distributions of MP population over characteristics. Although flow cytometry is one of the most powerful technologies of this type, the standard forward-versus-side-scattering plots of MPs and platelets (PLTs) overlap considerably because of similarity of their morphological characteristics. Moreover, ordinary flow cytometry is not capable of measurement of size and refractive index (RI) of MPs. In this study, we 1) employed the potential of the scanning flow cytometer (SFC) for identification and characterization of MPs from light scattering; 2) suggested the reference method to characterize MP morphology (size and RI) with high precision; and 3) determined the lowest size of a MP that can be characterized from light scattering with the SFC. We equipped the SFC with 405 and 488 nm lasers to measure the light-scattering profiles and side scattering from MPs, respectively. The developed two-stage method allowed accurate separation of PLTs and MPs in platelet-rich plasma. We used two optical models for MPs, a sphere and a bisphere, in the solution of the inverse light-scattering problem. This solution provides unprecedented precision in determination of size and RI of individual spherical MPs-median uncertainties (standard deviations) were 6 nm and 0.003, respectively. The developed method provides instrument-independent quantitative information on MPs, which can be used in studies of various factors affecting MP population. © 2015 International Society for Advancement of Cytometry.
Chioccioli, Maurizio; Hankamer, Ben; Ross, Ian L.
2014-01-01
Dry weight biomass is an important parameter in algaculture. Direct measurement requires weighing milligram quantities of dried biomass, which is problematic for small volume systems containing few cells, such as laboratory studies and high throughput assays in microwell plates. In these cases indirect methods must be used, inducing measurement artefacts which vary in severity with the cell type and conditions employed. Here, we utilise flow cytometry pulse width data for the estimation of cell density and biomass, using Chlorella vulgaris and Chlamydomonas reinhardtii as model algae and compare it to optical density methods. Measurement of cell concentration by flow cytometry was shown to be more sensitive than optical density at 750 nm (OD750) for monitoring culture growth. However, neither cell concentration nor optical density correlates well to biomass when growth conditions vary. Compared to the growth of C. vulgaris in TAP (tris-acetate-phosphate) medium, cells grown in TAP + glucose displayed a slowed cell division rate and a 2-fold increased dry biomass accumulation compared to growth without glucose. This was accompanied by increased cellular volume. Laser scattering characteristics during flow cytometry were used to estimate cell diameters and it was shown that an empirical but nonlinear relationship could be shown between flow cytometric pulse width and dry weight biomass per cell. This relationship could be linearised by the use of hypertonic conditions (1 M NaCl) to dehydrate the cells, as shown by density gradient centrifugation. Flow cytometry for biomass estimation is easy to perform, sensitive and offers more comprehensive information than optical density measurements. In addition, periodic flow cytometry measurements can be used to calibrate OD750 measurements for both convenience and accuracy. This approach is particularly useful for small samples and where cellular characteristics, especially cell size, are expected to vary during growth. PMID:24832156
Volden, T A; Reyelts, C D; Hoke, T A; Arikkath, J; Bonasera, S J
2015-12-01
Microglia are resident mononuclear phagocytes within the CNS parenchyma that intimately interact with neurons and astrocytes to remodel synapses and extracellular matrix. We briefly review studies elucidating the molecular pathways that underlie microglial surveillance, activation, chemotaxis, and phagocytosis; we additionally place these studies in a clinical context. We describe and validate an inexpensive and simple approach to obtain enriched single cell suspensions of quiescent parenchymal and perivascular microglia from the mouse cerebellum and hypothalamus. Following preparation of regional CNS single cell suspensions, we remove myelin debris, and then perform two serial enrichment steps for cells expressing surface CD11b. Myelin depletion and CD11b enrichment are both accomplished using antigen-specific magnetic beads in an automated cell separation system. Flow cytometry of the resultant suspensions shows a significant enrichment for CD11b(+)/CD45(+) cells (perivascular microglia) and CD11b(+)/CD45(-) cells (parenchymal microglia) compared to starting suspensions. Of note, cells from these enriched suspensions minimally express Aif1 (aka Iba1), suggesting that the enrichment process does not evoke significant microglial activation. However, these cells readily respond to a functional challenge (LPS) with significant changes in the expression of molecules specifically associated with microglia. We conclude that methods employing a combination of magnetic-bead based sorting and flow cytometry produce suspensions highly enriched for microglia that are appropriate for a variety of molecular and cellular assays.
de Carvalho Bittencourt, Marcelo; Kohler, Chantal; Henard, Sandrine; Rabaud, Christian; Béné, Marie C; Faure, Gilbert C
2013-07-08
Background. Quality assessment in flow cytometry cannot obey the same rules as those applicable to the measurement of chemical analytes. However, regular follow-up of known patients may provide a robust in-house control of cell subsets evaluation. Methods. Sequential blood samples assessed for 32 HIV patients over several years and showing good stability were retrospectively assessed to establish coefficient of variations of the percentages of CD3+, CD4+, CD8+ cells and CD4+ absolute counts. Results. Mean relative standard variations for the whole cohort were of 0.04, 0.14, 0.08 and 0.18 for CD3%, CD4% CD8% and CD4 absolute counts respectively. Discussion. In-house follow up of regularly checked compliant patients is a good alternative to traditional and costly repeatability and reproducibility studies for the validation of routine flow cytometry. © 2013 Clinical Cytometry Society. Copyright © 2013 Clinical Cytometry Society.
Optimized signal detection and analysis methods for in vivo photoacoustic flow cytometry
NASA Astrophysics Data System (ADS)
Wang, Qiyan; Zhou, Quanyu; Yang, Ping; Wang, Xiaoling; Niu, Zhenyu; Suo, Yuanzhen; He, Hao; Gao, Wenyuan; Tang, Shuo; Wei, Xunbin
2017-02-01
Melanoma is known as a malignant tumor of melanocytes, which usually appear in the blood circulation at the metastasis stage of cancer. Thus the detection of circulating melanoma cells is useful for early diagnosis and therapy of cancer. Here we have developed an in vivo photoacoustic flow cytometry (PAFC) based on the photoacoustic effect to detect melanoma cells. However, the raw signals we obtain from the target cells contain noises such as environmental sonic noises and electronic noises. Therefore we apply correlation comparison and feature separation methods to the detection and verification of the in vivo signals. Due to similar shape and structure of cells, the photoacoustic signals usually have similar vibration mode. By analyzing the correlations and the signal features in time domain and frequency domain, we are able to provide a method for separating photoacoustic signals generated by target cells from background noises. The method introduced here has proved to optimize the signal acquisition and signal processing, which can improve the detection accuracy in PAFC.
Riebeling, Christian; Pirow, Ralph; Becker, Klaus; Buesen, Roland; Eikel, Daniel; Kaltenhäuser, Johanna; Meyer, Frauke; Nau, Heinz; Slawik, Birgitta; Visan, Anke; Volland, Jutta; Spielmann, Horst; Luch, Andreas; Seiler, Andrea
2011-01-01
Teratogenicity can be predicted in vitro using the embryonic stem cell test (EST). The EST, which is based on the morphometric measurement of cardiomyocyte differentiation and cytotoxicity parameters, represents a scientifically validated method for the detection and classification of chemicals according to their teratogenic potency. Furthermore, an abbreviated protocol applying flow cytometry of intracellular marker proteins to determine differentiation into the cardiomyocyte lineage is available. Although valproic acid (VPA) is in worldwide clinical use as antiepileptic drug, it exhibits two severe side effects, i.e., teratogenicity and hepatotoxicity. These limitations have led to extensive research into derivatives of VPA. Here we chose VPA as model compound to test the applicability domain and to further evaluate the reliability of the EST. To this end, we study six closely related congeners of VPA and demonstrate that both the standard and the molecular flow cytometry-based EST are well suited to indicate differences in the teratogenic potency among VPA analogs that differ only in chirality or side chain length. Our data show that identical results can be obtained by using the standard EST or a shortened protocol based on flow cytometry of intracellular marker proteins. Both in vitro protocols enable to reliably determine differentiation of murine stem cells toward the cardiomyocyte lineage and to assess its chemical-mediated inhibition. PMID:21227905
Magbanua, Mark Jesus M; Solanki, Tulasi I; Ordonez, Andrea D; Hsiao, Feng; Park, John W
2017-01-01
Enumerating circulating tumor cells (CTCs) in blood and disseminated tumor cells (DTCs) in bone marrow has shown to be clinically useful, as elevated numbers of these cells predict poor clinical outcomes. Accurate detection and quantification is, however, difficult and technically challenging because CTCs and DTCs are extremely rare. We have developed a novel quantitative detection method for enumeration of CTCs and DTCs. Our approach consists of two steps: (1) EPCAM-based immunomagnetic enrichment followed by (2) flow cytometry (IE/FC). The assay takes approximately 2 h to complete. In addition to tumor cell enumeration, IE/FC offers opportunities for direct isolation of highly pure tumor cells for downstream molecular characterization.
Wang, Yue-Dan; Chen, Wei Feng
2004-11-01
To assess specific cytotoxic T lymphocytes (CTLs) against Severe acute respiratory syndrome (SARS)-coronavirus, a modified DimerX flow cytometry assay was performed with peripheral blood mononuclear cell (PBMC) from HLA-A2+ SARS-recovered donors at different time points post disease. CD8+DimerX-S1203+ CTLs were detected in the PBMC from these donors up to 3 months after recovery. The percentages of CD8+DimerX-S1203+ cells paralleled the numbers of interferon-gamma-positive spots in an ELISPOT assay using the same antigenic peptide. In conclusion, DimerX-based flow cytometry staining may prove to be a real-time method to screen for CTL directed at epitopes from a newly identified virus.
Role of CD81 and CD58 in minimal residual disease detection in pediatric B lymphoblastic leukemia.
Tsitsikov, E; Harris, M H; Silverman, L B; Sallan, S E; Weinberg, O K
2018-06-01
Minimal residual disease (MRD) in B lymphoblastic leukemia has been demonstrated to be a powerful predictor of clinical outcome in numerous studies in both children and adults. In this study, we evaluated 86 pediatric patients with both diagnostic and remission flow cytometry studies and compared expression of CD81, CD58, CD19, CD34, CD20, and CD38 in the detection of MRD. We evaluated 86 patients with B lymphoblastic leukemia who had both diagnostic studies and remission studies for the presence of MRD using multicolor flow cytometry. We established our detection limit for identifying abnormal lymphoblasts using serial dilutions. We also compared flow cytometry findings with molecular MRD detection in a subset of patients. We found that we can resolve differences between hematogones and lymphoblasts in 85 of 86 cases using a combination of CD45, CD19, CD34, CD10, CD20, CD38, CD58, and CD81. Our detection limit using flow cytometry is 0.002% for detecting a population of abnormal B lymphoblasts. Comparison with MRD assessment by molecular methods showed a high concordance rate with flow cytometry findings. Our study highlights importance of using multiple markers to detect MRD in B lymphoblastic leukemia. Our findings indicate that including both CD58 and CD81 markers in addition to CD19, CD34, CD20, CD38, and CD10 are helpful in MRD detection by flow cytometry. © 2018 John Wiley & Sons Ltd.
Besnard, G.; Garcia-Verdugo, C.; Rubio De Casas, R.; Treier, U. A.; Galland, N.; Vargas, P.
2008-01-01
Background Phylogenetic and phylogeographic investigations have been previously performed to study the evolution of the olive tree complex (Olea europaea). A particularly high genomic diversity has been found in north-west Africa. However, to date no exhaustive study has been addressed to infer putative polyploidization events and their evolutionary significance in the diversification of the olive tree and its relatives. Methods Representatives of the six olive subspecies were investigated using (a) flow cytometry to estimate genome content, and (b) six highly variable nuclear microsatellites to assess the presence of multiple alleles at co-dominant loci. In addition, nine individuals from a controlled cross between two individuals of O. europaea subsp. maroccana were characterized with microsatellites to check for chromosome inheritance. Key Results Based on flow cytometry and genetic analyses, strong evidence for polyploidy was obtained in subspp. cerasiformis (tetraploid) and maroccana (hexaploid), whereas the other subspecies appeared to be diploids. Agreement between flow cytometry and genetic analyses gives an alternative approach to chromosome counting to determine ploidy level of trees. Lastly, abnormalities in chromosomes inheritance leading to aneuploid formation were revealed using microsatellite analyses in the offspring from the controlled cross in subsp. maroccana. Conclusions This study constitutes the first report for multiple polyploidy in olive tree relatives. Formation of tetraploids and hexaploids may have played a major role in the diversification of the olive complex in north-west Africa. The fact that polyploidy is found in narrow endemic subspecies from Madeira (subsp. cerasiformis) and the Agadir Mountains (subsp. maroccana) suggests that polyploidization has been favoured to overcome inbreeding depression. Lastly, based on previous phylogenetic analyses, we hypothesize that subsp. cerasiformis resulted from hybridization between ancestors of subspp. guanchica and europaea. PMID:18024415
CytometryML: a data standard which has been designed to interface with other standards
NASA Astrophysics Data System (ADS)
Leif, Robert C.
2007-02-01
Because of the differences in the requirements, needs, and past histories including existing standards of the creating organizations, a single encompassing cytology-pathology standard will not, in the near future, replace the multiple existing or under development standards. Except for DICOM and FCS, these standardization efforts are all based on XML. CytometryML is a collection of XML schemas, which are based on the Digital Imaging and Communications in Medicine (DICOM) and Flow Cytometry Standard (FCS) datatypes. The CytometryML schemas contain attributes that link them to the DICOM standard and FCS. Interoperability with DICOM has been facilitated by, wherever reasonable, limiting the difference between CytometryML and the previous standards to syntax. In order to permit the Resource Description Framework, RDF, to reference the CytometryML datatypes, id attributes have been added to many CytometryML elements. The Laboratory Digital Imaging Project (LDIP) Data Exchange Specification and the Flowcyt standards development effort employ RDF syntax. Documentation from DICOM has been reused in CytometryML. The unity of analytical cytology was demonstrated by deriving a microscope type and a flow cytometer type from a generic cytometry instrument type. The feasibility of incorporating the Flowcyt gating schemas into CytometryML has been demonstrated. CytometryML is being extended to include many of the new DICOM Working Group 26 datatypes, which describe patients, specimens, and analytes. In situations where multiple standards are being created, interoperability can be facilitated by employing datatypes based on a common set of semantics and building in links to standards that employ different syntax.
Friedrich, Ralf P; Janko, Christina; Poettler, Marina; Tripal, Philipp; Zaloga, Jan; Cicha, Iwona; Dürr, Stephan; Nowak, Johannes; Odenbach, Stefan; Slabu, Ioana; Liebl, Maik; Trahms, Lutz; Stapf, Marcus; Hilger, Ingrid; Lyer, Stefan; Alexiou, Christoph
2015-01-01
Due to their special physicochemical properties, iron nanoparticles offer new promising possibilities for biomedical applications. For bench to bedside translation of super-paramagnetic iron oxide nanoparticles (SPIONs), safety issues have to be comprehensively clarified. To understand concentration-dependent nanoparticle-mediated toxicity, the exact quantification of intracellular SPIONs by reliable methods is of great importance. In the present study, we compared three different SPION quantification methods (ultraviolet spectrophotometry, magnetic particle spectroscopy, atomic adsorption spectroscopy) and discussed the shortcomings and advantages of each method. Moreover, we used those results to evaluate the possibility to use flow cytometric technique to determine the cellular SPION content. For this purpose, we correlated the side scatter data received from flow cytometry with the actual cellular SPION amount. We showed that flow cytometry provides a rapid and reliable method to assess the cellular SPION content. Our data also demonstrate that internalization of iron oxide nanoparticles in human umbilical vein endothelial cells is strongly dependent to the SPION type and results in a dose-dependent increase of toxicity. Thus, treatment with lauric acid-coated SPIONs (SEONLA) resulted in a significant increase in the intensity of side scatter and toxicity, whereas SEONLA with an additional protein corona formed by bovine serum albumin (SEONLA-BSA) and commercially available Rienso® particles showed only a minimal increase in both side scatter intensity and cellular toxicity. The increase in side scatter was in accordance with the measurements for SPION content by the atomic adsorption spectroscopy reference method. In summary, our data show that flow cytometry analysis can be used for estimation of uptake of SPIONs by mammalian cells and provides a fast tool for scientists to evaluate the safety of nanoparticle products. PMID:26170658
Porwit, A; Rajab, A
2015-05-01
Acute leukemia, myelodysplastic syndromes (MDS), myeloproliferative neoplasms and lymphomas are the most prevalent diagnoses in adults presenting with new onset cytopenia. Here, we describe two 10-color panels of surface markers (screening and comprehensive panel) applied at the Flow Cytometry Laboratory, University Health Network, Toronto, ON, Canada. A 10-color flow cytometry is applied using the stain-lyse-wash sample preparation method. In patients with <10% blasts and no clear involvement by hematological malignancy based on cytomorphological evaluation of bone marrow (BM) smear, the recently published one-tube 10-color 14-antibody screening panel is applied. This panel allows detection of major B- and T-cell abnormalities, enumeration of cells in blast region (CD45 dim), and gives insight into myeloid BM compartment, including calculation of four-parameter score for MDS-related abnormalities. In patients who present with ≥10 - <20% blasts in blood or BM smears, a comprehensive three-tube panel of surface markers is used up front. The analysis is focused on the detection of abnormal antigen expression patterns not seen in normal/reactive BM, according to the guidelines developed by International/European LeukemiaNet Working Group for Flow Cytometry in MDS. In patients with ≥20% blasts, an additional tube is added to allow the detection of cytoplasmic markers necessary to diagnose mixed phenotype acute leukemia. © 2015 John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Böhme, Steffi; Stärk, Hans-Joachim; Meißner, Tobias; Springer, Armin; Reemtsma, Thorsten; Kühnel, Dana; Busch, Wibke
2014-09-01
In order to quantify and compare the uptake of aluminum oxide nanoparticles of three different sizes into two human cell lines (skin keratinocytes (HaCaT) and lung epithelial cells (A549)), three analytical methods were applied: digestion followed by nebulization inductively coupled plasma mass spectrometry (neb-ICP-MS), direct laser ablation ICP-MS (LA-ICP-MS), and flow cytometry. Light and electron microscopy revealed an accumulation and agglomeration of all particle types within the cell cytoplasm, whereas no particles were detected in the cell nuclei. The internalized Al2O3 particles exerted no toxicity in the two cell lines after 24 h of exposure. The smallest particles with a primary particle size ( x BET) of 14 nm (Alu1) showed the lowest sedimentation velocity within the cell culture media, but were calculated to have settled completely after 20 h. Alu2 ( x BET = 111 nm) and Alu3 ( x BET = 750 nm) were calculated to reach the cell surface after 7 h and 3 min, respectively. The internal concentrations determined with the different methods lay in a comparable range of 2-8 µg Al2O3/cm2 cell layer, indicating the suitability of all methods to quantify the nanoparticle uptake. Nevertheless, particle size limitations of analytical methods using optical devices were demonstrated for LA-ICP-MS and flow cytometry. Furthermore, the consideration and comparison of particle properties as parameters for particle internalization revealed the particle size and the exposure concentration as determining factors for particle uptake.
Smirnov, Asya; Solga, Michael D; Lannigan, Joanne; Criss, Alison K
2015-08-01
Recognition, binding, internalization, and elimination of pathogens and cell debris are important functions of professional as well as non-professional phagocytes. However, high-throughput methods for quantifying cell-associated particles and discriminating bound from internalized particles have been lacking. Here we describe a protocol for using imaging flow cytometry to quantify the attached and phagocytosed particles that are associated with a population of cells. Cells were exposed to fluorescent particles, fixed, and exposed to an antibody of a different fluorophore that recognizes the particles. The antibody is added without cell permeabilization, such that the antibody only binds extracellular particles. Cells with and without associated particles were identified by imaging flow cytometry. For each cell with associated particles, a spot count algorithm was employed to quantify the number of extracellular (double fluorescent) and intracellular (single fluorescent) particles per cell, from which the percent particle internalization was determined. The spot count algorithm was empirically validated by examining the fluorescence and phase contrast images acquired by the flow cytometer. We used this protocol to measure binding and internalization of the bacterium Neisseria gonorrhoeae by primary human neutrophils, using different bacterial variants and under different cellular conditions. The results acquired using imaging flow cytometry agreed with findings that were previously obtained using conventional immunofluorescence microscopy. This protocol provides a rapid, powerful method for measuring the association and internalization of any particle by any cell type. Copyright © 2015 Elsevier B.V. All rights reserved.
In vivo plant flow cytometry: A first proof-of-concept
Nedosekin, Dmitry A.; Khodakovskaya, Mariya V.; Biris, Alexandru S.; Wang, Daoyuan; Xu, Yang; Villagarcia, Hector; Galanzha, Ekaterina I.; Zharov, Vladimir P.
2011-01-01
In vivo flow cytometry has facilitated advances in the ultrasensitive detection of tumor cells, bacteria, nanoparticles, dyes, and other normal and abnormal objects directly in blood and lymph circulatory systems. Here, we propose in vivo plant flow cytometry for the real-time noninvasive study of nanomaterial transport in xylem and phloem plant vascular systems. As a proof of this concept, we demonstrate in vivo real-time photoacoustic monitoring of quantum dot-carbon nanotube conjugate uptake and uptake by roots and spreading through stem to leaves in a tomato plant. In addition, in vivo scanning cytometry using multimodal photoacoustic, photothermal, and fluorescent detection schematics provided multiplex detection and identification of nanoparticles accumulated in plant leaves in the presence of intensive absorption, scattering, and autofluorescent backgrounds. The use of a portable fiber-based photoacoustic flow cytometer for studies of plant vasculature was demonstrated. These integrated cytometry modalities using both endogenous and exogenous contrast agents have a potential to open new avenues of in vivo study of the nutrients, products of photosynthesis and metabolism, nanoparticles, infectious agents, and other objects transported through plant vasculature. PMID:21905208
Gating mass cytometry data by deep learning.
Li, Huamin; Shaham, Uri; Stanton, Kelly P; Yao, Yi; Montgomery, Ruth R; Kluger, Yuval
2017-11-01
Mass cytometry or CyTOF is an emerging technology for high-dimensional multiparameter single cell analysis that overcomes many limitations of fluorescence-based flow cytometry. New methods for analyzing CyTOF data attempt to improve automation, scalability, performance and interpretation of data generated in large studies. Assigning individual cells into discrete groups of cell types (gating) involves time-consuming sequential manual steps, untenable for larger studies. We introduce DeepCyTOF, a standardization approach for gating, based on deep learning techniques. DeepCyTOF requires labeled cells from only a single sample. It is based on domain adaptation principles and is a generalization of previous work that allows us to calibrate between a target distribution and a source distribution in an unsupervised manner. We show that DeepCyTOF is highly concordant (98%) with cell classification obtained by individual manual gating of each sample when applied to a collection of 16 biological replicates of primary immune blood cells, even when measured across several instruments. Further, DeepCyTOF achieves very high accuracy on the semi-automated gating challenge of the FlowCAP-I competition as well as two CyTOF datasets generated from primary immune blood cells: (i) 14 subjects with a history of infection with West Nile virus (WNV), (ii) 34 healthy subjects of different ages. We conclude that deep learning in general, and DeepCyTOF specifically, offers a powerful computational approach for semi-automated gating of CyTOF and flow cytometry data. Our codes and data are publicly available at https://github.com/KlugerLab/deepcytof.git. yuval.kluger@yale.edu. Supplementary data are available at Bioinformatics online. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com
[Preparation of chicken red blood cells for calibration of flow cytometry].
Yin, Jian; Zhao, Shutao; Wu, Xiaodong; Wang, Ce; Wu, Yunliang
2013-01-01
To prepare stable chicken red blood cells for the calibration of flow cytometry. The traditional isolation method of chicken red blood cells was modified by incorporating gelatin technique, Ca2+-free HBSS treatment and low-speed centrifugation. The effect of fluorescence staining of the cells was improved by the addition of TritonX-100 to enhance the membrane permeability and Rnase enzymes to disintegrate RNA tiles. The modified method was compared with the traditional method for viability of the freshly isolated cells and the DNA content coefficient of variation (CV) of the fixed cells. Chicken red blood cells obtained by the modified method showed a significantly higher viability than those obtained by the traditional method [(98.5∓3.5)% vs (93.5∓2.7)%, P<0.05]. After glutaraldehyde fixation, the isolated cells with the modified method were stable during the 90-day preservation with a significantly lower CV than the cells obtained by the traditional method [(6.0∓0.3)% to 6.2∓0.4% vs (8.6∓0.5)% to (13.1∓1.4)%, P<0.01]. The chicken red blood cells isolated using the modified method can be applicable for calibration of flow cytometry.
Hyperchromatic laser scanning cytometry
NASA Astrophysics Data System (ADS)
Tárnok, Attila; Mittag, Anja
2007-02-01
In the emerging fields of high-content and high-throughput single cell analysis for Systems Biology and Cytomics multi- and polychromatic analysis of biological specimens has become increasingly important. Combining different technologies and staining methods polychromatic analysis (i.e. using 8 or more fluorescent colors at a time) can be pushed forward to measure anything stainable in a cell, an approach termed hyperchromatic cytometry. For cytometric cell analysis microscope based Slide Based Cytometry (SBC) technologies are ideal as, unlike flow cytometry, they are non-consumptive, i.e. the analyzed sample is fixed on the slide. Based on the feature of relocation identical cells can be subsequently reanalyzed. In this manner data on the single cell level after manipulation steps can be collected. In this overview various components for hyperchromatic cytometry are demonstrated for a SBC instrument, the Laser Scanning Cytometer (Compucyte Corp., Cambridge, MA): 1) polychromatic cytometry, 2) iterative restaining (using the same fluorochrome for restaining and subsequent reanalysis), 3) differential photobleaching (differentiating fluorochromes by their different photostability), 4) photoactivation (activating fluorescent nanoparticles or photocaged dyes), and 5) photodestruction (destruction of FRET dyes). With the intelligent combination of several of these techniques hyperchromatic cytometry allows to quantify and analyze virtually all components of relevance on the identical cell. The combination of high-throughput and high-content SBC analysis with high-resolution confocal imaging allows clear verification of phenotypically distinct subpopulations of cells with structural information. The information gained per specimen is only limited by the number of available antibodies and by sterical hindrance.
A critical evaluation of a flow cytometer used for detecting enterococci in recreational waters.
King, Dawn N; Brenner, Kristen P; Rodgers, Mark R
2007-06-01
The current U. S. Environmental Protection Agency-approved method for enterococci (Method 1600) in recreational water is a membrane filter (MF) method that takes 24 hours to obtain results. If the recreational water is not in compliance with the standard, the risk of exposure to enteric pathogens may occur before the water is identified as hazardous. Because flow cytometry combined with specific fluorescent antibodies has the potential to be used as a rapid detection method for microorganisms, this technology was evaluated as a rapid, same-day method to detect enterococci in bathing beach waters. The flow cytometer chosen for this study was a laser microbial detection system designed to detect labeled antibodies. A comparison of MF counts with flow cytometry counts of enterococci in phosphate buffer and sterile-filtered recreational water showed good agreement between the two methods. However, when flow cytometry was used, the counts were several orders of magnitude higher than the MF counts with no correlation to Enterococcus spike concentrations. The unspiked sample controls frequently had higher counts than the samples spiked with enterococci. Particles within the spiked water samples were probably counted as target cells by the flow cytometer because of autofluorescence or non-specific adsorption of antibody and carryover to subsequent samples. For these reasons, this technology may not be suitable for enterococci detection in recreational waters. Improvements in research and instrument design that will eliminate high background and carryover may make this a viable technology in the
Development of a novel cell sorting method that samples population diversity in flow cytometry.
Osborne, Geoffrey W; Andersen, Stacey B; Battye, Francis L
2015-11-01
Flow cytometry based electrostatic cell sorting is an important tool in the separation of cell populations. Existing instruments can sort single cells into multi-well collection plates, and keep track of cell of origin and sorted well location. However currently single sorted cell results reflect the population distribution and fail to capture the population diversity. Software was designed that implements a novel sorting approach, "Slice and Dice Sorting," that links a graphical representation of a multi-well plate to logic that ensures that single cells are sampled and sorted from all areas defined by the sort region/s. Therefore the diversity of the total population is captured, and the more frequently occurring or rarer cell types are all sampled. The sorting approach was tested computationally, and using functional cell based assays. Computationally we demonstrate that conventional single cell sorting can sample as little as 50% of the population diversity dependant on the population distribution, and that Slice and Dice sorting samples much more of the variety present within a cell population. We then show by sorting single cells into wells using the Slice and Dice sorting method that there are cells sorted using this method that would be either rarely sorted, or not sorted at all using conventional single cell sorting approaches. The present study demonstrates a novel single cell sorting method that samples much more of the population diversity than current methods. It has implications in clonal selection, stem cell sorting, single cell sequencing and any areas where population heterogeneity is of importance. © 2015 International Society for Advancement of Cytometry.
[Fiat Lux. May be no more true in cytometry! Go to mass and spectrum but still stay classic].
Idziorek, Thierry; Cazareth, Julie; Blanc, Catherine; Jouy, Nathalie; Bourdely, Pierre; Corneau, Aurélien
2018-05-01
The last decade has been an era of accelerated technological progress for flow cytometry. New technologies have been developed such as mass cytometry in which standard fluorochromes have been replaced by lanthanide-based non-radioactive metals and by spectral cytometry that measures the complete fluorescence spectrum. In this review, we schematically describe conventional, mass and spectral cytometry and present the plus and minus of each technology. © 2018 médecine/sciences – Inserm.
SCENERY: a web application for (causal) network reconstruction from cytometry data.
Papoutsoglou, Georgios; Athineou, Giorgos; Lagani, Vincenzo; Xanthopoulos, Iordanis; Schmidt, Angelika; Éliás, Szabolcs; Tegnér, Jesper; Tsamardinos, Ioannis
2017-07-03
Flow and mass cytometry technologies can probe proteins as biological markers in thousands of individual cells simultaneously, providing unprecedented opportunities for reconstructing networks of protein interactions through machine learning algorithms. The network reconstruction (NR) problem has been well-studied by the machine learning community. However, the potentials of available methods remain largely unknown to the cytometry community, mainly due to their intrinsic complexity and the lack of comprehensive, powerful and easy-to-use NR software implementations specific for cytometry data. To bridge this gap, we present Single CEll NEtwork Reconstruction sYstem (SCENERY), a web server featuring several standard and advanced cytometry data analysis methods coupled with NR algorithms in a user-friendly, on-line environment. In SCENERY, users may upload their data and set their own study design. The server offers several data analysis options categorized into three classes of methods: data (pre)processing, statistical analysis and NR. The server also provides interactive visualization and download of results as ready-to-publish images or multimedia reports. Its core is modular and based on the widely-used and robust R platform allowing power users to extend its functionalities by submitting their own NR methods. SCENERY is available at scenery.csd.uoc.gr or http://mensxmachina.org/en/software/. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.
Analysis of Cellular DNA Content by Flow Cytometry.
Darzynkiewicz, Zbigniew; Huang, Xuan; Zhao, Hong
2017-10-02
Cellular DNA content can be measured by flow cytometry with the aim of : (1) revealing cell distribution within the major phases of the cell cycle, (2) estimating frequency of apoptotic cells with fractional DNA content, and/or (3) disclosing DNA ploidy of the measured cell population. In this unit, simple and universally applicable methods for staining fixed cells are presented, as are methods that utilize detergents and/or proteolytic treatment to permeabilize cells and make DNA accessible to fluorochrome. Additionally, supravital cell staining with Hoechst 33342, which is primarily used for sorting live cells based on DNA-content differences for their subsequent culturing, is described. Also presented are methods for staining cell nuclei isolated from paraffin-embedded tissues. Available algorithms are listed for deconvolution of DNA-content-frequency histograms to estimate percentage of cells in major phases of the cell cycle and frequency of apoptotic cells with fractional DNA content. © 2017 by John Wiley & Sons, Inc. Copyright © 2017 John Wiley and Sons, Inc.
Analysis of Cellular DNA Content by Flow Cytometry.
Darzynkiewicz, Zbigniew; Huang, Xuan; Zhao, Hong
2017-11-01
Cellular DNA content can be measured by flow cytometry with the aim of : (1) revealing cell distribution within the major phases of the cell cycle, (2) estimating frequency of apoptotic cells with fractional DNA content, and/or (3) disclosing DNA ploidy of the measured cell population. In this unit, simple and universally applicable methods for staining fixed cells are presented, as are methods that utilize detergents and/or proteolytic treatment to permeabilize cells and make DNA accessible to fluorochrome. Additionally, supravital cell staining with Hoechst 33342, which is primarily used for sorting live cells based on DNA-content differences for their subsequent culturing, is described. Also presented are methods for staining cell nuclei isolated from paraffin-embedded tissues. Available algorithms are listed for deconvolution of DNA-content-frequency histograms to estimate percentage of cells in major phases of the cell cycle and frequency of apoptotic cells with fractional DNA content. © 2017 by John Wiley & Sons, Inc. Copyright © 2017 John Wiley and Sons, Inc.
Label-free detection of circulating melanoma cells by in vivo photoacoustic flow cytometry
NASA Astrophysics Data System (ADS)
Wang, Xiaoling; Yang, Ping; Liu, Rongrong; Niu, Zhenyu; Suo, Yuanzhen; He, Hao; Gao, Wenyuan; Tang, Shuo; Wei, Xunbin
2016-03-01
Melanoma is a malignant tumor of melanocytes. Melanoma cells have high light absorption due to melanin highly contained in melanoma cells. This property is employed for the detection of circulating melanoma cell by in vivo photoacoustic flow cytometry (PAFC), which is based on photoacoustic effect. Compared to in vivo flow cytometry based on fluorescence, PAFC can employ high melanin content of melanoma cells as endogenous biomarkers to detect circulating melanoma cells in vivo. We have developed in vitro experiments to prove the ability of PAFC system of detecting photoacoustic signals from melanoma cells. For in vivo experiments, we have constructed a model of melanoma tumor bearing mice by inoculating highly metastatic murine melanoma cancer cells, B16F10 with subcutaneous injection. PA signals are detected in the blood vessels of mouse ears in vivo. The raw signal detected from target cells often contains some noise caused by electronic devices, such as background noise and thermal noise. We choose the Wavelet denoising method to effectively distinguish the target signal from background noise. Processing in time domain and frequency domain would be combined to analyze the signal after denoising. This algorithm contains time domain filter and frequency transformation. The frequency spectrum image of the signal contains distinctive features that can be used to analyze the property of target cells or particles. The processing methods have a great potential for analyzing signals accurately and rapidly. By counting circulating melanoma cells termly, we obtain the number variation of circulating melanoma cells as melanoma metastasized. Those results show that PAFC is a noninvasive and label-free method to detect melanoma metastases in blood or lymph circulation.
Data File Standard for Flow Cytometry, version FCS 3.1.
Spidlen, Josef; Moore, Wayne; Parks, David; Goldberg, Michael; Bray, Chris; Bierre, Pierre; Gorombey, Peter; Hyun, Bill; Hubbard, Mark; Lange, Simon; Lefebvre, Ray; Leif, Robert; Novo, David; Ostruszka, Leo; Treister, Adam; Wood, James; Murphy, Robert F; Roederer, Mario; Sudar, Damir; Zigon, Robert; Brinkman, Ryan R
2010-01-01
The flow cytometry data file standard provides the specifications needed to completely describe flow cytometry data sets within the confines of the file containing the experimental data. In 1984, the first Flow Cytometry Standard format for data files was adopted as FCS 1.0. This standard was modified in 1990 as FCS 2.0 and again in 1997 as FCS 3.0. We report here on the next generation flow cytometry standard data file format. FCS 3.1 is a minor revision based on suggested improvements from the community. The unchanged goal of the standard is to provide a uniform file format that allows files created by one type of acquisition hardware and software to be analyzed by any other type.The FCS 3.1 standard retains the basic FCS file structure and most features of previous versions of the standard. Changes included in FCS 3.1 address potential ambiguities in the previous versions and provide a more robust standard. The major changes include simplified support for international characters and improved support for storing compensation. The major additions are support for preferred display scale, a standardized way of capturing the sample volume, information about originality of the data file, and support for plate and well identification in high throughput, plate based experiments. Please see the normative version of the FCS 3.1 specification in Supporting Information for this manuscript (or at http://www.isac-net.org/ in the Current standards section) for a complete list of changes.
Data File Standard for Flow Cytometry, Version FCS 3.1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spidlen, Josef; Moore, Wayne; Parks, David
2009-11-10
The flow cytometry data file standard provides the specifications needed to completely describe flow cytometry data sets within the confines of the file containing the experimental data. In 1984, the first Flow Cytometry Standard format for data files was adopted as FCS 1.0. This standard was modified in 1990 as FCS 2.0 and again in 1997 as FCS 3.0. We report here on the next generation flow cytometry standard data file format. FCS 3.1 is a minor revision based on suggested improvements from the community. The unchanged goal of the standard is to provide a uniform file format that allowsmore » files created by one type of acquisition hardware and software to be analyzed by any other type. The FCS 3.1 standard retains the basic FCS file structure and most features of previous versions of the standard. Changes included in FCS 3.1 address potential ambiguities in the previous versions and provide a more robust standard. The major changes include simplified support for international characters and improved support for storing compensation. The major additions are support for preferred display scale, a standardized way of capturing the sample volume, information about originality of the data file, and support for plate and well identification in high throughput, plate based experiments. Please see the normative version of the FCS 3.1 specification in Supporting Information for this manuscript (or at http://www.isac-net.org/ in the Current standards section) for a complete list of changes.« less
Duong, Hong Phuoc; Wissing, Karl Martin; Tram, Nathalie; Mascart, Georges; Lepage, Philippe
2016-01-01
Automated flow cytometry of urine remains an incompletely validated method to rule out urinary tract infection (UTI) in children. This cross-sectional analytical study was performed to compare the predictive values of flow cytometry and a dipstick test as initial diagnostic tests for UTI in febrile children and prospectively included 1,106 children (1,247 episodes). Urine culture was used as the gold standard test for diagnosing UTI. The performance of screening tests to diagnose UTI were established using receiver operating characteristic (ROC) analysis. Among these 1,247 febrile episodes, 221 UTIs were diagnosed (17.7% [95% confidence interval {CI}, 15.6 to 19.8%]). The area under the ROC curve for flow cytometry white blood cell (WBC) counts (0.99 [95% CI, 0.98 to 0.99]) was significantly superior to that for red blood cell (0.74 [95% CI, 0.70 to 0.78]) and bacterial counts (0.89 [95% CI, 0.87 to 0.92]) (P < 0.001). Urinary WBC counts also had a significantly higher area under the ROC curve than that of the leukocyte esterase (LE) dipstick (0.92 [95% CI, 0.90 to 0.94]), nitrite dipstick (0.83 [95% CI, 0.80 to 0.87]), or the combination of positive LE and/or nitrite dipstick (0.91 [95% CI, 0.89 to 0.93]) test (P < 0.001). The presence of ≥35 WBC/μl of urine was the best cutoff point, yielding both a high sensitivity (99.5% [95% CI, 99 to 100%]) and an acceptable specificity (80.6% [95% CI, 78 to 83%]). Using this cutoff point would have reduced the number of samples sent to the laboratory for culture by 67%. In conclusion, the determination of urinary WBC counts by flow cytometry provides optimal performance as an initial diagnostic test for UTI in febrile children. PMID:27682127
Flow cytometry for receptor analysis from ex-vivo brain tissue in adult rat.
Benoit, A; Guillamin, M; Aitken, P; Smith, P F; Philoxene, B; Sola, B; Poulain, L; Coquerel, A; Besnard, S
2018-07-01
Flow cytometry allows single-cell analysis of peripheral biological samples and is useful in many fields of research and clinical applications, mainly in hematology, immunology, and oncology. In the neurosciences, the flow cytometry separation method was first applied to stem cell extraction from healthy or cerebral tumour tissue and was more recently tested in order to phenotype brain cells, hippocampal neurogenesis, and to detect prion proteins. However, it remains sparsely applied in quantifying membrane receptors in relation to synaptic plasticity. We aimed to optimize a flow cytometric procedure for receptor quantification in neurons and non-neurons. A neural dissociation process, myelin separation, fixation, and membrane permeability procedures were optimized to maximize cell survival and analysis in hippocampal tissue obtained from adult rodents. We then aimed to quantify membrane muscarinic acetylcholine receptors (mAChRs) in rats with and without bilateral vestibular loss (BVL). mAChR's were quantified for neuronal and non-neuronal cells in the hippocampus and striatum following BVL. At day 30 but not at day 7 following BVL, there was a significant increase (P ≤ 0.05) in the percentage of neurons expressing M 2/4 mAChRs in both the hippocampus and the striatum. Here, we showed that flow cytometry appears to be a reliable method of membrane receptor quantification in ex-vivo brain tissue. Copyright © 2018 Elsevier B.V. All rights reserved.
In vitro flow cytometry-based screening platform for cellulase engineering
Körfer, Georgette; Pitzler, Christian; Vojcic, Ljubica; Martinez, Ronny; Schwaneberg, Ulrich
2016-01-01
Ultrahigh throughput screening (uHTS) plays an essential role in directed evolution for tailoring biocatalysts for industrial applications. Flow cytometry-based uHTS provides an efficient coverage of the generated protein sequence space by analysis of up to 107 events per hour. Cell-free enzyme production overcomes the challenge of diversity loss during the transformation of mutant libraries into expression hosts, enables directed evolution of toxic enzymes, and holds the promise to efficiently design enzymes of human or animal origin. The developed uHTS cell-free compartmentalization platform (InVitroFlow) is the first report in which a flow cytometry-based screened system has been combined with compartmentalized cell-free expression for directed cellulase enzyme evolution. InVitroFlow was validated by screening of a random cellulase mutant library employing a novel screening system (based on the substrate fluorescein-di-β-D-cellobioside), and yielded significantly improved cellulase variants (e.g. CelA2-H288F-M1 (N273D/H288F/N468S) with 13.3-fold increased specific activity (220.60 U/mg) compared to CelA2 wildtype: 16.57 U/mg). PMID:27184298
Addressing the malaria drug resistance challenge using flow cytometry to discover new antimalarials.
Grimberg, Brian T; Jaworska, Maria M; Hough, Lindsay B; Zimmerman, Peter A; Phillips, James G
2009-09-15
A new flow cytometry method that uses an optimized DNA and RNA staining strategy to monitor the growth and development of the Plasmodium falciparum strain W2mef has been used in a pilot study and has identified Bay 43-9006 1, SU 11274 2, and TMC 125 5 as compounds that exhibit potent (<1 microM) overall and ring stage in vitro antimalarial activity.
Mee-Sook Kim; Ned B. Klopfenstein; Geral I. McDonald; Kathiravetpillai Arumuganathan
2001-01-01
For assessments of intraspecific mating using flow cytometry and fluorescence microscopy, two compatible basidiospore-derived isolates were selected from each of four parental basidiomata of North American Biological Species (NABS) X. The nuclear status in NABS X varied with basidiospore-derived isolates. Nuclei within basidiospore-derived isolates existed as haploids...
Pumpless Microflow Cytometry Enabled by Viscosity Modulation and Immunobead Labeling.
Kim, Byeongyeon; Oh, Sein; Shin, Suyeon; Yim, Sang-Gu; Yang, Seung Yun; Hahn, Young Ki; Choi, Sungyoung
2018-06-19
Major challenges of miniaturizing flow cytometry include obviating the need for bulky, expensive, and complex pump-based fluidic and laser-based optical systems while retaining the ability to detect target cells based on their unique surface receptors. We addressed these critical challenges by (i) using a viscous liquid additive to control flow rate passively, without external pumping equipment, and (ii) adopting an immunobead assay that can be quantified with a portable fluorescence cell counter based on a blue light-emitting diode. Such novel features enable pumpless microflow cytometry (pFC) analysis by simply dropping a sample solution onto the inlet reservoir of a disposable cell-counting chamber. With our pFC platform, we achieved reliable cell counting over a dynamic range of 9-298 cells/μL. We demonstrated the practical utility of the platform by identifying a type of cancer cell based on CD326, the epithelial cell adhesion molecule. This portable microflow cytometry platform can be applied generally to a range of cell types using immunobeads labeled with specific antibodies, thus making it valuable for cell-based and point-of-care diagnostics.
Rise of the micromachines: microfluidics and the future of cytometry.
Wlodkowic, Donald; Darzynkiewicz, Zbigniew
2011-01-01
The past decade has brought many innovations to the field of flow and image-based cytometry. These advancements can be seen in the current miniaturization trends and simplification of analytical components found in the conventional flow cytometers. On the other hand, the maturation of multispectral imaging cytometry in flow imaging and the slide-based laser scanning cytometers offers great hopes for improved data quality and throughput while proving new vistas for the multiparameter, real-time analysis of cells and tissues. Importantly, however, cytometry remains a viable and very dynamic field of modern engineering. Technological milestones and innovations made over the last couple of years are bringing the next generation of cytometers out of centralized core facilities while making it much more affordable and user friendly. In this context, the development of microfluidic, lab-on-a-chip (LOC) technologies is one of the most innovative and cost-effective approaches toward the advancement of cytometry. LOC devices promise new functionalities that can overcome current limitations while at the same time promise greatly reduced costs, increased sensitivity, and ultra high throughputs. We can expect that the current pace in the development of novel microfabricated cytometric systems will open up groundbreaking vistas for the field of cytometry, lead to the renaissance of cytometric techniques and most importantly greatly support the wider availability of these enabling bioanalytical technologies. Copyright © 2011 Elsevier Inc. All rights reserved.
Rise of the Micromachines: Microfluidics and the Future of Cytometry
Wlodkowic, Donald; Darzynkiewicz, Zbigniew
2011-01-01
The past decade has brought many innovations to the field of flow and image-based cytometry. These advancements can be seen in the current miniaturization trends and simplification of analytical components found in the conventional flow cytometers. On the other hand, the maturation of multispectral imaging cytometry in flow imaging and the slide-based laser scanning cytometers offers great hopes for improved data quality and throughput while proving new vistas for the multiparameter, real-time analysis of cells and tissues. Importantly, however, cytometry remains a viable and very dynamic field of modern engineering. Technological milestones and innovations made over the last couple of years are bringing the next generation of cytometers out of centralized core facilities while making it much more affordable and user friendly. In this context, the development of microfluidic, lab-on-a-chip (LOC) technologies is one of the most innovative and cost-effective approaches toward the advancement of cytometry. LOC devices promise new functionalities that can overcome current limitations while at the same time promise greatly reduced costs, increased sensitivity, and ultra high throughputs. We can expect that the current pace in the development of novel microfabricated cytometric systems will open up groundbreaking vistas for the field of cytometry, lead to the renaissance of cytometric techniques and most importantly greatly support the wider availability of these enabling bioanalytical technologies. PMID:21704837
Flow cytometry enables identification of sporophytic eliciting stress treatments in gametic cells.
Ribalta, F M; Croser, J S; Ochatt, S J
2012-01-01
Flow cytometry was used to quantify the effect of individual and combined stress treatments on elicitation of androgenesis by analyzing the relative nuclear DNA content of in vitro cultured microspores of Pisum sativum L. Differences in relative nuclear DNA content of microspores within anthers after stress treatments were clearly evident from the flow cytometry profiles, and permitted us to predict whether a combination of stresses were elicitors or enhancers of androgenesis. This is the first report to assess the effect of various stress treatments in a plant species based on relative nuclear DNA content and to use this information to categorize them as 'elicitors' or 'enhancers'. Flow cytometry represents a simple, quick and reliable way to analyze and discriminate the effect of various stress treatments on elicitation of androgenesis. These results form a solid basis for further efforts designed to enhance responses and to extend double haploid technology to other legumes. Copyright © 2011 Elsevier GmbH. All rights reserved.
Rapid flow cytometric measurement of protein inclusions and nuclear trafficking
Whiten, D. R.; San Gil, R.; McAlary, L.; Yerbury, J. J.; Ecroyd, H.; Wilson, M. R.
2016-01-01
Proteinaceous cytoplasmic inclusions are an indicator of dysfunction in normal cellular proteostasis and a hallmark of many neurodegenerative diseases. We describe a simple and rapid new flow cytometry-based method to enumerate, characterise and, if desired, physically recover protein inclusions from cells. This technique can analyse and resolve a broad variety of inclusions differing in both size and protein composition, making it applicable to essentially any model of intracellular protein aggregation. The method also allows rapid quantification of the nuclear trafficking of fluorescently labelled molecules. PMID:27516358
Ferroptosis and Cell Death Analysis by Flow Cytometry.
Chen, Daishi; Eyupoglu, Ilker Y; Savaskan, Nicolai
2017-01-01
Cell death and its recently discovered regulated form ferroptosis are characterized by distinct morphological, electrophysiological, and pharmacological features. In particular ferroptosis can be induced by experimental compounds and clinical drugs (i.e., erastin, sulfasalazine, sorafenib, and artesunate) in various cell types and cancer cells. Pharmacologically, this cell death process can be inhibited by iron chelators and lipid peroxidation inhibitors. Relevance of this specific cell death form has been found in different pathological conditions such as cancer, neurotoxicity, neurodegeneration, and ischemia. Distinguishing cell viability and cell death is essential for experimental and clinical applications and a key component in flow cytometry experiments. Dead cells can compromise the integrity of the data by nonspecific binding of antibodies and dyes. Therefore it is essential that dead cells are robustly and reproducibly identified and characterized by means of cytometry application. Here we describe a procedure to detect and quantify cell death and its specific form ferroptosis based on standard flow cytometry techniques.
Flow cytometry shows added value in diagnosing lymphoma in brain biopsies.
van der Meulen, Matthijs; Bromberg, Jacoline E C; Lam, King H; Dammers, Ruben; Langerak, Anton W; Doorduijn, Jeanette K; Kros, Johan M; van den Bent, Martin J; van der Velden, Vincent H J
2018-05-10
To assess the sensitivity, specificity and turnaround time of flow cytometric analysis on brain biopsies compared to histology plus immunohistochemistry analysis in tumors with clinical suspicion of lymphoma. All brain biopsies performed between 2010 and 2015 at our institution and analyzed by both immunohistochemistry and flow cytometry were included in this retrospective study. Immunohistochemistry was considered the gold standard. In a total of 77 biopsies from 71 patients, 49 lymphomas were diagnosed by immunohistochemistry, flow cytometry results were concordant in 71 biopsies (92,2%). We found a specificity and sensitivity of flow cytometry of 100% and 87,8%, respectively. The time between the biopsy and reporting the result (turnaround time) was significantly shorter for flow cytometry, compared to immunohistochemistry (median: 1 versus 5 days). Flow cytometry has a high specificity and can confirm the diagnosis of a lymphoma significantly faster than immunohistochemistry. This allows for rapid initiation of treatment in this highly aggressive tumor. However, since its sensitivity is less than 100%, we recommend to perform histology plus immunohistochemistry in parallel to flow cytometry. This article is protected by copyright. All rights reserved. © 2018 International Clinical Cytometry Society.
A flow cytometry-based strategy to identify and express IgM from VH1-69+ clonal peripheral B cells.
Charles, Edgar D; Orloff, Michael I M; Dustin, Lynn B
2011-01-05
Pathologic rheumatoid factor (RF) levels are hallmarks of several human diseases. Production of monoclonal RF in vitro is essential for studies of the antigenic specificities of RF, as well as for a dissection of the mechanisms of aberrant RF+ B cell activation. We have expanded upon previous methods to develop a flow cytometry-based method to efficiently clone monoclonal antibodies (mAbs) from humans with expansions of RF-like, immunoglobulin heavy chain variable region (IgVH) 1-69 gene segment-containing B cells. The cloned variable regions are expressed as IgM and produced during culture at concentrations between 5 and 20 μg/ml. Using this system, we show that clonal Igs from patients with HCV-related mixed cryoglobulinemia, when expressed as IgM, have RF activity. We anticipate that this system will be useful for the cloning and expression of mAbs partially encoded by VH1-69 and for determination of the reactivity patterns of polyspecific, low-affinity IgMs of human pathogenic importance. Copyright © 2010 Elsevier B.V. All rights reserved.
Juan-García, Ana; Manyes, Lara; Ruiz, María-José; Font, Guillermina
2013-06-01
This review gives an overview of flow cytometry applications to toxicological studies of several physiological target sites of mycotoxins on different mammalian cell lines. Mycotoxins are secondary metabolites of fungi that may be present in food, feed, air and water. The increasing presence of mycotoxins in crops, their wide distribution in the food chain, and their potential for toxicity demonstrate the need for further knowledge. Flow cytometry has become a valuable tool in mycotoxin studies in recent years for the rapid analysis of single cells in a mixture. In toxicology, the power of these methods lies in the possibility of determining a wide range of cell parameters, providing valuable information to elucidate cell growth and viability, metabolic activity, mitochondrial membrane potential and membrane integrity mechanisms. There are studies using flow cytometry technique on Alternaria, Aspergillus, Fusarium and Penicillium mycotoxins including information about cell type, assay conditions and functional parameters. Most of the studies collected in the literature are on deoxynivalenol and zearalenone mycotoxins. Cell cycle analysis and apoptosis are the processes more widely investigated. Copyright © 2013 Elsevier Ltd. All rights reserved.
Use of flow cytometry to monitor cell damage and predict fermentation activity of dried yeasts.
Attfield, P V; Kletsas, S; Veal, D A; van Rooijen, R; Bell, P J
2000-08-01
Viable dried yeast is used as an inoculum for many fermentations in the baking and wine industries. The fermentative activity of yeast in bread dough or grape must is a critical parameter of process efficiency. Here, it is shown that fluorescent stains and flow cytometry can be used in concert to predict the abilities of populations of dried bakers' and wine yeasts to ferment after rehydration. Fluorescent dyes that stain cells only if they have damaged membrane potential (oxonol) or have increased membrane permeability (propidium iodide) were used to analyse, by flow cytometry, populations of rehydrated yeasts. A strong relationship (r2 = 0.99) was found between the percentages of populations staining with the oxonol and the degree of cell membrane damage as measured by the more traditional method of leakage of intracellular compounds. There were also were good negative relationships (r2 > or = 0.83) between fermentation by rehydrated bakers' or wine dry yeasts and percentage of populations staining with either oxonol or propidium iodide. Fluorescent staining with flow cytometry confirmed that factors such as vigour of dried yeast mixing in water, soaking before stirring, rehydration in water or fermentation medium and temperature of rehydration have profound effects on subsequent yeast vitality. These experiments indicate the potential of flow cytometry as a rapid means of predicting the fermentation performance of dried bakers' and wine yeasts.
Di Bucchianico, Sebastiano; Cappellini, Francesca; Le Bihanic, Florane; Zhang, Yuning; Dreij, Kristian; Karlsson, Hanna L
2017-01-01
The widespread production and use of nanoparticles calls for faster and more reliable methods to assess their safety. The main aim of this study was to investigate the genotoxicity of three reference TiO 2 nanomaterials (NM) within the frame of the FP7-NANoREG project, with a particular focus on testing the applicability of mini-gel comet assay and micronucleus (MN) scoring by flow cytometry. BEAS-2B cells cultured under serum-free conditions were exposed to NM100 (anatase, 50-150nm), NM101 (anatase, 5-8nm) and NM103 (rutile, 20-28nm) for 3, 24 or 48h mainly at concentrations 1-30 μg/ml. In the mini-gel comet assay (eight gels per slide), we included analysis of (i) DNA strand breaks, (ii) oxidised bases (Fpg-sensitive sites) and (iii) light-induced DNA damage due to photocatalytic activity. Furthermore, MN assays were used and we compared the results of more high-throughput MN scoring with flow cytometry to that of cytokinesis-block MN cytome assay scored manually using a microscope. Various methods were used to assess cytotoxic effects and the results showed in general no or low effects at the doses tested. A weak genotoxic effect of the tested TiO 2 materials was observed with an induction of oxidised bases for all three materials of which NM100 was the most potent. When the comet slides were briefly exposed to lab light, a clear induction of DNA strand breaks was observed for the anatase materials, but not for the rutile. This highlights the risk of false positives when testing photocatalytically active materials if light is not properly avoided. A slight increase in MN formation for NM103 was observed in the different MN assays at the lower doses tested (1 and 5 μg/ml). We conclude that mini-gel comet assay and MN scoring using flow cytometry successfully can be used to efficiently study cytotoxic and genotoxic properties of nanoparticles. © The Author 2016. Published by Oxford University Press on behalf of the UK Environmental Mutagen Society.
Di Bucchianico, Sebastiano; Cappellini, Francesca; Le Bihanic, Florane; Zhang, Yuning; Dreij, Kristian; Karlsson, Hanna L.
2017-01-01
The widespread production and use of nanoparticles calls for faster and more reliable methods to assess their safety. The main aim of this study was to investigate the genotoxicity of three reference TiO2 nanomaterials (NM) within the frame of the FP7-NANoREG project, with a particular focus on testing the applicability of mini-gel comet assay and micronucleus (MN) scoring by flow cytometry. BEAS-2B cells cultured under serum-free conditions were exposed to NM100 (anatase, 50–150nm), NM101 (anatase, 5–8nm) and NM103 (rutile, 20–28nm) for 3, 24 or 48h mainly at concentrations 1–30 μg/ml. In the mini-gel comet assay (eight gels per slide), we included analysis of (i) DNA strand breaks, (ii) oxidised bases (Fpg-sensitive sites) and (iii) light-induced DNA damage due to photocatalytic activity. Furthermore, MN assays were used and we compared the results of more high-throughput MN scoring with flow cytometry to that of cytokinesis-block MN cytome assay scored manually using a microscope. Various methods were used to assess cytotoxic effects and the results showed in general no or low effects at the doses tested. A weak genotoxic effect of the tested TiO2 materials was observed with an induction of oxidised bases for all three materials of which NM100 was the most potent. When the comet slides were briefly exposed to lab light, a clear induction of DNA strand breaks was observed for the anatase materials, but not for the rutile. This highlights the risk of false positives when testing photocatalytically active materials if light is not properly avoided. A slight increase in MN formation for NM103 was observed in the different MN assays at the lower doses tested (1 and 5 μg/ml). We conclude that mini-gel comet assay and MN scoring using flow cytometry successfully can be used to efficiently study cytotoxic and genotoxic properties of nanoparticles. PMID:27382040
2012-01-10
flow cytometry, locked nucleic acid, sRNA, Vibrio , Date Published: 1/10/2012 This is an open-access article distributed under the terms of the Creative...solubilization process to maintain a 10 mL volume. Aliquot the 60% dextran sulfate solution and store at -20 °C until use. 1. Harvest 1x108 cells of...bioluminescent Vibrio campbellii or your bacteria of interest and transfer them into a 1.5 mL microcentrifuge tube. This quantity of cells provides
A CLIPS expert system for clinical flow cytometry data analysis
NASA Technical Reports Server (NTRS)
Salzman, G. C.; Duque, R. E.; Braylan, R. C.; Stewart, C. C.
1990-01-01
An expert system is being developed using CLIPS to assist clinicians in the analysis of multivariate flow cytometry data from cancer patients. Cluster analysis is used to find subpopulations representing various cell types in multiple datasets each consisting of four to five measurements on each of 5000 cells. CLIPS facts are derived from results of the clustering. CLIPS rules are based on the expertise of Drs. Stewart, Duque, and Braylan. The rules incorporate certainty factors based on case histories.
Benítez, Francisco Moreno; Camacho, Antonio Letrán; del Cuvillo Bernal, Alfonso; de Medina, Pedro Lobatón Sánchez; García Cózar, Francisco J; Romeu, Marisa Espinazo
2014-01-01
There is an increase in the incidence of pollen related allergy, thus information on pollen schedules would be a great asset for physicians to improve the clinical care of patients. Like cypress pollen sensitization shows a high prevalence among the causes of allergic rhinitis, and therefore it is of interest to use it like a model of study, distinguishing cypress pollen, pollen count, and allergenic load level. In this work, we use a flow cytometry based technique to obtain both Cupressus arizonica pollen count and allergenic load, using specific rabbit polyclonal antibody Cup a1 and its comparison with optical microscopy technique measurement. Airborne samples were collected from Burkard Spore-Trap and Burkard Cyclone Cupressus arizonica pollen was studied using specific rabbit polyclonal antibody Cup a1, labeled with AlexaFluor(®) 488 or 750 and analysed by Flow Cytometry in both an EPICS XL and Cyan ADP cytometers (Beckman Coulter(®) ). Optical microscopy study was realized with a Leica optical microscope. Bland and Altman was used to determine agreement between both techniques measured. We can identify three different populations based on rabbit polyclonal antibody Cup a1 staining. The main region (44.5%) had 97.3% recognition, a second region (25%) with 28% and a third region (30.5%) with 68% respectively. Immunofluorescence and confocal microscopy showed that main region corresponds to whole pollen grains, the second region are pollen without exine and the third region is constituted by smaller particles with allergenic properties. Pollen schedule shows a higher correlation measured by optical microscopy and flow cytometry in the pollen count with a P-value: 0.0008 E(-2) and 0.0002 with regard to smaller particles, so the Bland and Altman measurement showed a good correlation between them, P-value: 0.0003. Determination of pollen count and allergenic load by flow cytometry represents an important tool in the determination of airborne respiratory allergens. We showed that not only whole pollen but also smaller particles could induce allergic sensitization. This is the first study where flow cytometry is used for calculating pollen counts and allergenic load. Copyright © 2013 Clinical Cytometry Society.
Dubeau-Laramée, Geneviève; Rivière, Christophe; Jean, Isabelle; Mermut, Ozzy; Cohen, Luchino Y
2014-04-01
A fiber-optic based flow cytometry platform was designed to build a portable and robust instrument for space applications. At the core of the Microflow1 is a unique fiber-optic flow cell fitted to a fluidic system and fiber coupled to the source and detection channels. A Microflow1 engineering unit was first tested and benchmarked against a commercial flow cytometer as a reference in a standard laboratory environment. Testing in parabolic flight campaigns was performed to establish Microflow1's performance in weightlessness, before operating the new platform on the International Space Station. Microflow1 had comparable performances to commercial systems, and operated remarkably and robustly in weightlessness (microgravity). Microflow1 supported immunophenotyping as well as microbead-based multiplexed cytokine assays in the space environment and independently of gravity levels. Results presented here provide evidence that this fiber-optic cytometer technology is inherently compatible with the space environment with negligible compromise to analytical performance. © 2013 International Society for Advancement of Cytometry.
Tang, Vera A; Renner, Tyler M; Fritzsche, Anna K; Burger, Dylan; Langlois, Marc-André
2017-12-19
Retroviruses and small EVs overlap in size, buoyant densities, refractive indices and share many cell-derived surface markers making them virtually indistinguishable by standard biochemical methods. This poses a significant challenge when purifying retroviruses for downstream analyses or for phenotypic characterization studies of markers on individual virions given that EVs are a major contaminant of retroviral preparations. Nanoscale flow cytometry (NFC), also called flow virometry, is an adaptation of flow cytometry technology for the analysis of individual nanoparticles such as extracellular vesicles (EVs) and retroviruses. In this study we systematically optimized NFC parameters for the detection of retroviral particles in the range of 115-130 nm, including viral production, sample labeling, laser power and voltage settings. By using the retroviral envelope glycoprotein as a selection marker, and evaluating a number of fluorescent dyes and labeling methods, we demonstrate that it is possible to confidently distinguish retroviruses from small EVs by NFC. Our findings make it now possible to individually phenotype genetically modified retroviral particles that express a fluorescent envelope glycoprotein without removing EV contaminants from the sample.
A general method for bead-enhanced quantitation by flow cytometry
Montes, Martin; Jaensson, Elin A.; Orozco, Aaron F.; Lewis, Dorothy E.; Corry, David B.
2009-01-01
Flow cytometry provides accurate relative cellular quantitation (percent abundance) of cells from diverse samples, but technical limitations of most flow cytometers preclude accurate absolute quantitation. Several quantitation standards are now commercially available which, when added to samples, permit absolute quantitation of CD4+ T cells. However, these reagents are limited by their cost, technical complexity, requirement for additional software and/or limited applicability. Moreover, few studies have validated the use of such reagents in complex biological samples, especially for quantitation of non-T cells. Here we show that addition to samples of known quantities of polystyrene fluorescence standardization beads permits accurate quantitation of CD4+ T cells from complex cell samples. This procedure, here termed single bead-enhanced cytofluorimetry (SBEC), was equally capable of enumerating eosinophils as well as subcellular fragments of apoptotic cells, moieties with very different optical and fluorescent characteristics. Relative to other proprietary products, SBEC is simple, inexpensive and requires no special software, suggesting that the method is suitable for the routine quantitation of most cells and other particles by flow cytometry. PMID:17067632
A simple clot based assay for detection of procoagulant cell-derived microparticles.
Patil, Rucha; Ghosh, Kanjaksha; Shetty, Shrimati
2016-05-01
Cell-derived microparticles (MPs) are important biomarkers in many facets of medicine. However, the MP detection methods used till date are costly and time consuming. The main aim of this study was to standardize an in-house clot based screening method for MP detection which would not only be specific and sensitive, but also inexpensive. Four different methods of MP assessment were performed and the results correlated. Using the flow cytometry technique as the gold standard, 25 samples with normal phosphatidylserine (PS) expressing MP levels and 25 samples with elevated levels were selected, which was cross checked by the commercial STA Procoag PPL clotting time (CT) assay. A simple recalcification time and an in-house clot assay were the remaining two tests. The in-house test measures the CT after the addition of calcium chloride to MP rich plasma, following incubation with Russell viper venom and phospholipid free plasma. The CT obtained by the in-house assay significantly correlated with the results obtained by flow cytometry (R2=0.87, p<0.01). Though preliminary, the in-house assay seems to be efficient, inexpensive and promising. It could definitely be utilized routinely for procoagulant MP assessment in various clinical settings.
Dissecting the Role of IGFBP-2 in Development of Acute Myeloid Leukemia
2011-06-01
surface proteins on freshly isolated and cultured cells, as determined by flow cytometry ... Surface Immune Molecules on Phenotypic HSCs during Culture (A and B) A summary of the result of flow cytometry analysis of surface expression of indicated...from the distant implanted tumor were counted by flow cytometry analysis. The flow cytometry result was confirmed by counting GFP+ surface foci of
Hogg, Karen; Thomas, Jerry; Ashford, David; Cartwright, Jared; Coldwell, Ruth; Weston, Daniel J; Pillmoor, John; Surry, Dominic; O'Toole, Peter
2015-07-01
Flow cytometry is a powerful tool for the quantitation of fluorescence and is proven to be able to correlate the fluorescence intensity to the number of protein on cells surface. Mass spectroscopy can also be used to determine the number of proteins per cell. Here we have developed two methods, using flow cytometry and mass spectroscopy to quantify number of transporters in human cells. These two approaches were then used to analyse the same samples so that a direct comparison could be made. Transporters have a major impact on the behaviour of a diverse number of drugs in human systems. While active uptake studies by transmembrane protein transporters using model substrates are routinely undertaken in human cell lines and hepatocytes as part of drug discovery and development, the interpretation of these results is currently limited by the inability to quantify the number of transporters present in the test samples. Here we provide a flow cytometric method for accurate quantification of transporter levels both on the cell surface and within the cell, and compare this to a quantitative mass spectrometric approach. Two transporters were selected for the study: OATP1B1 (also known as SLCO1B1, LST-1, OATP-C, OATP2) due to its important role in hepatic drug uptake and elimination; P-gp (also known as P-glycoprotein, MDR1, ABCB1) as a well characterised system and due to its potential impact on oral bioavailability, biliary and renal clearance, and brain penetration of drugs that are substrates for this transporter. In all cases the mass spectrometric method gave higher levels than the flow cytometry method. However, the two methods showed very similar trends in the relative ratios of both transporters in the hepatocyte samples investigated. The P-gp antibody allowed quantitative discrimination between externally facing transporters located in the cytoplasmic membrane and the total number of transporters on and in the cell. The proportion of externally facing transporter varied considerably in the four hepatocyte samples analysed, ranging from only 6% to 35% of intact and viable cells. The sample with only 6% externally facing transporter was further analysed by confocal microscopy which qualitatively confirmed the low level of transporter in the membrane and the large internal population. Here we prove that flow cytometry is an important tool for future protein analysis as it can not only quantify the number of proteins that a cell express but also identify the number of proteins on the surface and it is easy to apply for routine assays. Copyright © 2015 Elsevier Inc. All rights reserved.
Gámez-Díaz, Laura; Sigmund, Elena C; Reiser, Veronika; Vach, Werner; Jung, Sophie; Grimbacher, Bodo
2018-01-01
The diagnosis of lipopolysaccharide-responsive beige-like-anchor-protein (LRBA) deficiency currently relies on gene sequencing approaches that do not support a timely diagnosis and clinical management. We developed a rapid and sensitive test for clinical implementation based on the detection of LRBA protein by flow cytometry in peripheral blood cells after stimulation. LRBA protein was assessed in a prospective cohort of 54 healthy donors and 57 patients suspected of LRBA deficiency. Receiver operating characteristics analysis suggested an LRBA:MFI ratio cutoff point of 2.6 to identify LRBA-deficient patients by FACS with 94% sensitivity and 80% specificity and to discriminate them from patients with a similar clinical picture but other disease-causing mutations. This easy flow cytometry-based assay allows a fast screening of patients with suspicion of LRBA deficiency reducing therefore the number of patients requiring LRBA sequencing and accelerating the treatment implementation. Detection of biallelic mutations in LRBA is however required for a definitive diagnosis.
Microfluidic flow cytometer for quantifying photobleaching of fluorescent proteins in cells
Lubbeck, Jennifer L.; Dean, Kevin M.; Ma, Hairong; Palmer, Amy E.; Jimenez, Ralph
2012-01-01
Traditional flow cytometers are capable of rapid cellular assays on the basis of fluorescence intensity and light scatter. Microfluidic flow cytometers have largely followed the same path of technological development as their traditional counterparts, however the significantly smaller transport distance and resulting lower cell speeds in microchannels provides for the opportunity to detect novel spectroscopic signatures based on multiple, non-temporally-coincident excitation beams. Here, we characterize the design and operation of a cytometer with a 3-beam, probe/bleach/probe geometry, employing HeLa suspension cells expressing fluorescent proteins. The data collection rate exceeds 20 cells/s under a range of beam intensities (5 kW – 179 kW/cm2). The measured percent photobleaching (ratio of fluorescence intensities excited by the first and third beams: Sbeam3/Sbeam1) partially resolves a mixture of four red fluorescent proteins in mixed samples. Photokinetic simulations are presented and demonstrate that the percent photobleaching reflects a combination of the reversible and irreversible photobleaching kinetics. By introducing a photobleaching optical signature, which complements traditional fluorescence intensity-based detection, this method adds another dimension to multi-channel fluorescence cytometry, and provides a means for flow-cytometry-based screening of directed libraries of fluorescent protein photobleaching. PMID:22424298
A flow-cytometry-based method for detecting simultaneously five allergens in a complex food matrix.
Otto, Gaetan; Lamote, Amandine; Deckers, Elise; Dumont, Valery; Delahaut, Philippe; Scippo, Marie-Louise; Pleck, Jessica; Hillairet, Caroline; Gillard, Nathalie
2016-12-01
To avoid carry-over contamination with allergens, food manufacturers implement quality control strategies relying primarily on detection of allergenic proteins by ELISA. Although sensitive and specific, this method allowed detection of only one allergen per analysis and effective control policies were thus based on multiplying the number of tests done in order to cover the whole range of allergens. We present in this work an immunoassay for the simultaneous detection of milk, egg, peanut, mustard and crustaceans in cookies samples. The method was based on a combination of flow cytometry with competitive ELISA where microbeads were used as sorbent surface. The test was able to detect the presence of the five allergens with median inhibitory concentrations (IC50) ranging from 2.5 to 15 mg/kg according to the allergen to be detected. The lowest concentrations of contaminants inducing a significant difference of signal between non-contaminated controls and test samples were 2 mg/kg of peanut, 5 mg/kg of crustaceans, 5 mg/kg of milk, 5 mg/kg of mustard and 10 mg/kg of egg. Assay sensitivity was influenced by the concentration of primary antibodies added to the sample extract for the competition and by the concentration of allergenic proteins bound to the surface of the microbeads.
Muto, Satoru; Sugiura, Syo-Ichiro; Nakajima, Akiko; Horiuchi, Akira; Inoue, Masahiro; Saito, Keisuke; Isotani, Shuji; Yamaguchi, Raizo; Ide, Hisamitsu; Horie, Shigeo
2014-10-01
We aimed to identify patients with a chief complaint of hematuria who could safely avoid unnecessary radiation and instrumentation in the diagnosis of bladder cancer (BC), using automated urine flow cytometry to detect isomorphic red blood cells (RBCs) in urine. We acquired urine samples from 134 patients over the age of 35 years with a chief complaint of hematuria and a positive urine occult blood test or microhematuria. The data were analyzed using the UF-1000i (®) (Sysmex Co., Ltd., Kobe, Japan) automated urine flow cytometer to determine RBC morphology, which was classified as isomorphic or dysmorphic. The patients were divided into two groups (BC versus non-BC) for statistical analysis. Multivariate logistic regression analysis was used to determine the predictive value of flow cytometry versus urine cytology, the bladder tumor antigen test, occult blood in urine test, and microhematuria test. BC was confirmed in 26 of 134 patients (19.4 %). The area under the curve for RBC count using the automated urine flow cytometer was 0.94, representing the highest reference value obtained in this study. Isomorphic RBCs were detected in all patients in the BC group. On multivariate logistic regression analysis, only isomorphic RBC morphology was significantly predictive for BC (p < 0.001). Analytical parameters such as sensitivity, specificity, positive predictive value, and negative predictive value of isomorphic RBCs in urine were 100.0, 91.7, 74.3, and 100.0 %, respectively. Detection of urinary isomorphic RBCs using automated urine flow cytometry is a reliable method in the diagnosis of BC with hematuria.
Martínez-Esparza, M; Sarazin, A; Jouy, N; Poulain, D; Jouault, T
2006-07-31
The yeast Candida albicans is an opportunistic pathogen, part of the normal human microbial flora that causes infections in immunocompromised individuals with a high morbidity and mortality levels. Recognition of yeasts by host cells is based on components of the yeast cell wall, which are considered part of its virulence attributes. Cell wall glycans play an important role in the continuous interchange that regulates the balance between saprophytism and parasitism, and also between resistance and infection. Some of these molecular entities are expressed both by the pathogenic yeast C. albicans and by Saccharomyces cerevisiae, a related non-pathogenic yeast, involving similar molecular mechanisms and receptors for recognition. In this work we have exploited flow cytometry methods for probing surface glycans of the yeasts. We compared glycan expression by C. albicans and by S. cerevisiae, and studied the effect of culture conditions. Our results show that the expression levels of alpha- and beta-linked mannosides as well as beta-glucans can be successfully evaluated by flow cytometry methods using different antibodies independent of agglutination reactions. We also found that the surface expression pattern of beta-mannosides detected by monoclonal or polyclonal antibodies are differently modulated during the growth course. These data indicate that the yeast beta-mannosides exposed on mannoproteins and/or phospholipomannan are increased in stationary phase, whereas those linked to mannan are not affected by the yeast growth phase. The cytometric method described here represents a useful tool to investigate to what extent C. albicans is able to regulate its glycan surface expression and therefore modify its virulence properties.
Kenthirapalan, Sanketha; Waters, Andrew P.; Matuschewski, Kai; Kooij, Taco W.A.
2012-01-01
The most critical bottleneck in the generation of recombinant Plasmodium berghei parasites is the mandatory in vivo cloning step following successful genetic manipulation. This study describes a new technique for rapid selection of recombinant P. berghei parasites. The method is based on flow cytometry to isolate isogenic parasite lines and represents a major advance for the field, in that it will speed the generation of recombinant parasites as well as cut down on animal use significantly. High expression of GFP during blood infection, a prerequisite for robust separation of transgenic lines by flow cytometry, was achieved. Isogenic recombinant parasite populations were isolated even in the presence of a 100-fold excess of wild-type (WT) parasites. Aquaglyceroporin (AQP) loss-of-function mutants and parasites expressing a tagged AQP were generated to validate this approach. aqp− parasites grow normally within the WT phenotypic range during blood infection of NMRI mice. Similarly, colonization of the insect vector and establishment of an infection after mosquito transmission were unaffected, indicating that AQP is dispensable for life cycle progression in vivo under physiological conditions, refuting its use as a suitable drug target. Tagged AQP localized to perinuclear structures and not the parasite plasma membrane. We suggest that flow-cytometric isolation of isogenic parasites overcomes the major roadblock towards a genome-scale repository of mutant and transgenic malaria parasite lines. PMID:23137753
AirLab: a cloud-based platform to manage and share antibody-based single-cell research.
Catena, Raúl; Özcan, Alaz; Jacobs, Andrea; Chevrier, Stephane; Bodenmiller, Bernd
2016-06-29
Single-cell analysis technologies are essential tools in research and clinical diagnostics. These methods include flow cytometry, mass cytometry, and other microfluidics-based technologies. Most laboratories that employ these methods maintain large repositories of antibodies. These ever-growing collections of antibodies, their multiple conjugates, and the large amounts of data generated in assays using specific antibodies and conditions makes a dedicated software solution necessary. We have developed AirLab, a cloud-based tool with web and mobile interfaces, for the organization of these data. AirLab streamlines the processes of antibody purchase, organization, and storage, antibody panel creation, results logging, and antibody validation data sharing and distribution. Furthermore, AirLab enables inventory of other laboratory stocks, such as primers or clinical samples, through user-controlled customization. Thus, AirLab is a mobile-powered and flexible tool that harnesses the capabilities of mobile tools and cloud-based technology to facilitate inventory and sharing of antibody and sample collections and associated validation data.
The detection of infective protozoan parasites contained in large volume environmental samples represents a unique challenge in environmental parasitology. Compounding this problem is the fact that infective stages of many protozoan parasites do not readily replicate in media or ...
Futamura, Koji; Sekino, Masashi; Hata, Akihiro; Ikebuchi, Ryoyo; Nakanishi, Yasutaka; Egawa, Gyohei; Kabashima, Kenji; Watanabe, Takeshi; Furuki, Motohiro; Tomura, Michio
2015-09-01
Flow cytometric analysis with multicolor fluoroprobes is an essential method for detecting biological signatures of cells. Here, we present a new full-spectral flow cytometer (spectral-FCM). Unlike conventional flow cytometer, this spectral-FCM acquires the emitted fluorescence for all probes across the full-spectrum from each cell with 32 channels sequential PMT unit after dispersion with prism, and extracts the signals of each fluoroprobe based on the spectral shape of each fluoroprobe using unique algorithm in high speed, high sensitive, accurate, automatic and real-time. The spectral-FCM detects the continuous changes in emission spectra from green to red of the photoconvertible protein, KikGR with high-spectral resolution and separates spectrally-adjacent fluoroprobes, such as FITC (Emission peak (Em) 519 nm) and EGFP (Em 507 nm). Moreover, the spectral-FCM can measure and subtract autofluorescence of each cell providing increased signal-to-noise ratios and improved resolution of dim samples, which leads to a transformative technology for investigation of single cell state and function. These advances make it possible to perform 11-color fluorescence analysis to visualize movement of multilinage immune cells by using KikGR-expressing mice. Thus, the novel spectral flow cytometry improves the combinational use of spectrally-adjacent various FPs and multicolor fluorochromes in metabolically active cell for the investigation of not only the immune system but also other research and clinical fields of use. © 2015 International Society for Advancement of Cytometry.
Castillo-Hair, Sebastian M.; Sexton, John T.; Landry, Brian P.; Olson, Evan J.; Igoshin, Oleg A.; Tabor, Jeffrey J.
2017-01-01
Flow cytometry is widely used to measure gene expression and other molecular biological processes with single cell resolution via fluorescent probes. Flow cytometers output data in arbitrary units (a.u.) that vary with the probe, instrument, and settings. Arbitrary units can be converted to the calibrated unit molecules of equivalent fluorophore (MEF) using commercially available calibration particles. However, there is no convenient, non-proprietary tool available to perform this calibration. Consequently, most researchers report data in a.u., limiting interpretation. Here, we report a software tool named FlowCal to overcome current limitations. FlowCal can be run using an intuitive Microsoft Excel interface, or customizable Python scripts. The software accepts Flow Cytometry Standard (FCS) files as inputs and is compatible with different calibration particles, fluorescent probes, and cell types. Additionally, FlowCal automatically gates data, calculates common statistics, and produces publication quality plots. We validate FlowCal by calibrating a.u. measurements of E. coli expressing superfolder GFP (sfGFP) collected at 10 different detector sensitivity (gain) settings to a single MEF value. Additionally, we reduce day-to-day variability in replicate E. coli sfGFP expression measurements due to instrument drift by 33%, and calibrate S. cerevisiae mVenus expression data to MEF units. Finally, we demonstrate a simple method for using FlowCal to calibrate fluorescence units across different cytometers. FlowCal should ease the quantitative analysis of flow cytometry data within and across laboratories and facilitate the adoption of standard fluorescence units in synthetic biology and beyond. PMID:27110723
Label-Free, Flow-Imaging Methods for Determination of Cell Concentration and Viability.
Sediq, A S; Klem, R; Nejadnik, M R; Meij, P; Jiskoot, Wim
2018-05-30
To investigate the potential of two flow imaging microscopy (FIM) techniques (Micro-Flow Imaging (MFI) and FlowCAM) to determine total cell concentration and cell viability. B-lineage acute lymphoblastic leukemia (B-ALL) cells of 2 different donors were exposed to ambient conditions. Samples were taken at different days and measured with MFI, FlowCAM, hemocytometry and automated cell counting. Dead and live cells from a fresh B-ALL cell suspension were fractionated by flow cytometry in order to derive software filters based on morphological parameters of separate cell populations with MFI and FlowCAM. The filter sets were used to assess cell viability in the measured samples. All techniques gave fairly similar cell concentration values over the whole incubation period. MFI showed to be superior with respect to precision, whereas FlowCAM provided particle images with a higher resolution. Moreover, both FIM methods were able to provide similar results for cell viability as the conventional methods (hemocytometry and automated cell counting). FIM-based methods may be advantageous over conventional cell methods for determining total cell concentration and cell viability, as FIM measures much larger sample volumes, does not require labeling, is less laborious and provides images of individual cells.
Mass cytometry: a highly multiplexed single-cell technology for advancing drug development.
Atkuri, Kondala R; Stevens, Jeffrey C; Neubert, Hendrik
2015-02-01
Advanced single-cell analysis technologies (e.g., mass cytometry) that help in multiplexing cellular measurements in limited-volume primary samples are critical in bridging discovery efforts to successful drug approval. Mass cytometry is the state-of-the-art technology in multiparametric single-cell analysis. Mass cytometers (also known as cytometry by time-of-flight or CyTOF) combine the cellular analysis principles of traditional fluorescence-based flow cytometry with the selectivity and quantitative power of inductively coupled plasma-mass spectrometry. Standard flow cytometry is limited in the number of parameters that can be measured owing to the overlap in signal when detecting fluorescently labeled antibodies. Mass cytometry uses antibodies tagged to stable isotopes of rare earth metals, which requires minimal signal compensation between the different metal tags. This unique feature enables researchers to seamlessly multiplex up to 40 independent measurements on single cells. In this overview we first present an overview of mass cytometry and compare it with traditional flow cytometry. We then discuss the emerging and potential applications of CyTOF technology in the pharmaceutical industry, including quantitative and qualitative deep profiling of immune cells and their applications in assessing drug immunogenicity, extensive mapping of signaling networks in single cells, cell surface receptor quantification and multiplexed internalization kinetics, multiplexing sample analysis by barcoding, and establishing cell ontologies on the basis of phenotype and/or function. We end with a discussion of the anticipated impact of this technology on drug development lifecycle with special emphasis on the utility of mass cytometry in deciphering a drug's pharmacokinetics and pharmacodynamics relationship. Copyright © 2014 by The American Society for Pharmacology and Experimental Therapeutics.
Guide to red fluorescent proteins and biosensors for flow cytometry.
Piatkevich, Kiryl D; Verkhusha, Vladislav V
2011-01-01
Since the discovery of the first red fluorescent protein (RFP), named DsRed, 12 years ago, a wide pallet of red-shifted fluorescent proteins has been cloned and biotechnologically developed into monomeric fluorescent probes for optical microscopy. Several new types of monomeric RFPs that change the emission wavelength either with time, called fluorescent timers, or after a brief irradiation with violet light, known as photoactivatable proteins, have been also engineered. Moreover, RFPs with a large Stokes shift of fluorescence emission have been recently designed. Because of their distinctive excitation and fluorescence detection conditions developed specifically for microscopy, these fluorescent probes can be suboptimal for flow cytometry. Here, we have selected and summarized the advanced orange, red, and far-red fluorescent proteins with the properties specifically required for the flow cytometry applications. Their effective brightness was calculated for the laser sources available for the commercial flow cytometers and sorters. Compatibility of the fluorescent proteins of different colors in a multiparameter flow cytometry was determined. Novel FRET pairs, utilizing RFPs, RFP-based intracellular biosensors, and their application to a high-throughput screening, are also discussed. Copyright © 2011 Elsevier Inc. All rights reserved.
Using flow cytometry to estimate pollen DNA content: improved methodology and applications
Kron, Paul; Husband, Brian C.
2012-01-01
Background and Aims Flow cytometry has been used to measure nuclear DNA content in pollen, mostly to understand pollen development and detect unreduced gametes. Published data have not always met the high-quality standards required for some applications, in part due to difficulties inherent in the extraction of nuclei. Here we describe a simple and relatively novel method for extracting pollen nuclei, involving the bursting of pollen through a nylon mesh, compare it with other methods and demonstrate its broad applicability and utility. Methods The method was tested across 80 species, 64 genera and 33 families, and the data were evaluated using established criteria for estimating genome size and analysing cell cycle. Filter bursting was directly compared with chopping in five species, yields were compared with published values for sonicated samples, and the method was applied by comparing genome size estimates for leaf and pollen nuclei in six species. Key Results Data quality met generally applied standards for estimating genome size in 81 % of species and the higher best practice standards for cell cycle analysis in 51 %. In 41 % of species we met the most stringent criterion of screening 10 000 pollen grains per sample. In direct comparison with two chopping techniques, our method produced better quality histograms with consistently higher nuclei yields, and yields were higher than previously published results for sonication. In three binucleate and three trinucleate species we found that pollen-based genome size estimates differed from leaf tissue estimates by 1·5 % or less when 1C pollen nuclei were used, while estimates from 2C generative nuclei differed from leaf estimates by up to 2·5 %. Conclusions The high success rate, ease of use and wide applicability of the filter bursting method show that this method can facilitate the use of pollen for estimating genome size and dramatically improve unreduced pollen production estimation with flow cytometry. PMID:22875815
Flow cytometric detection method for DNA samples
Nasarabadi, Shanavaz [Livermore, CA; Langlois, Richard G [Livermore, CA; Venkateswaran, Kodumudi S [Round Rock, TX
2011-07-05
Disclosed herein are two methods for rapid multiplex analysis to determine the presence and identity of target DNA sequences within a DNA sample. Both methods use reporting DNA sequences, e.g., modified conventional Taqman.RTM. probes, to combine multiplex PCR amplification with microsphere-based hybridization using flow cytometry means of detection. Real-time PCR detection can also be incorporated. The first method uses a cyanine dye, such as, Cy3.TM., as the reporter linked to the 5' end of a reporting DNA sequence. The second method positions a reporter dye, e.g., FAM.TM. on the 3' end of the reporting DNA sequence and a quencher dye, e.g., TAMRA.TM., on the 5' end.
Flow cytometric detection method for DNA samples
Nasarabadi, Shanavaz [Livermore, CA; Langlois, Richard G [Livermore, CA; Venkateswaran, Kodumudi S [Livermore, CA
2006-08-01
Disclosed herein are two methods for rapid multiplex analysis to determine the presence and identity of target DNA sequences within a DNA sample. Both methods use reporting DNA sequences, e.g., modified conventional Taqman.RTM. probes, to combine multiplex PCR amplification with microsphere-based hybridization using flow cytometry means of detection. Real-time PCR detection can also be incorporated. The first method uses a cyanine dye, such as, Cy3.TM., as the reporter linked to the 5' end of a reporting DNA sequence. The second method positions a reporter dye, e.g., FAM, on the 3' end of the reporting DNA sequence and a quencher dye, e.g., TAMRA, on the 5' end.
Role of receptor occupancy assays by flow cytometry in drug development.
Stewart, Jennifer J; Green, Cherie L; Jones, Nicholas; Liang, Meina; Xu, Yuanxin; Wilkins, Danice E C; Moulard, Maxime; Czechowska, Kamila; Lanham, David; McCloskey, Thomas W; Ferbas, John; van der Strate, Barry W A; Högerkorp, Carl-Magnus; Wyant, Timothy; Lackey, Alan; Litwin, Virginia
2016-03-01
The measurement of the binding of a biotherapeutic to its cellular target, receptor occupancy (RO), is increasingly important in development of biologically-based therapeutic agents. Receptor occupancy (RO) assays by flow cytometry describe the qualitative and/or quantitative assessment of the binding of a therapeutic agent to its cell surface target. Such RO assays can be as simple as measuring the number of cell surface receptors bound by an antireceptor therapeutic agent or can be designed to address more complicated scenarios such as internalization or shedding events once a receptor engages the administered therapeutic agent. Data generated from RO assays can also be used to model whether given doses of an experimental therapeutic agent and their administration schedules lead to predicted levels of receptor occupancy and whether the receptor is modulated (up or down) on cells engaged by the therapeutic agent. There are a variety of approaches that can be used when undertaking RO assays and with the ability to measure distinct subsets in heterogeneous populations, flow cytometry is ideally suited to RO measurements. This article highlights the importance of RO assays on the flow cytometric platform in the development of biotherapeutic agents. © 2016 The Authors Cytometry Part B: Clinical Cytometry Published by Wiley Periodicals, Inc.
2013-01-31
have similar surface markers . We found that topically delivered ASCs are engrafted and proliferate in the wounds. We showed that transplanted ASCs...Material Command (W81XWH-10-2-0054). Flow cytometry was supported by the Northwestern University Flow Cytometry Facility and a Cancer Center Support...blasticidin. GFP expressing cells were further selected by flow cytometry using the Northwestern University Flow Cytometry Facility. Treatment of MSCs
An efficient and rapid transgenic pollen screening and detection method using flow cytometry.
Moon, Hong S; Eda, Shigetoshi; Saxton, Arnold M; Ow, David W; Stewart, C Neal
2011-01-01
Assaying for transgenic pollen, a major vector of transgene flow, provides valuable information and essential data for the study of gene flow and assessing the effectiveness of transgene containment. Most studies have employed microscopic screening methods or progeny analyses to estimate the frequency of transgenic pollen. However, these methods are time-consuming and laborious when large numbers of pollen grains must be analyzed to look for rare transgenic pollen grains. Thus, there is an urgent need for the development of a simple, rapid, and high throughput analysis method for transgenic pollen analysis. In this study, our objective was to determine the accuracy of using flow cytometry technology for transgenic pollen quantification in practical application where transgenic pollen is not frequent. A suspension of non-transgenic tobacco pollen was spiked with a known amount of verified transgenic tobacco pollen synthesizing low or high amounts of green fluorescent protein (GFP). The flow cytometric method detected approximately 75% and 100% of pollen grains synthesizing low and high amounts of GFP, respectively. The method is rapid, as it is able to count 5000 pollen grains per minute-long run. Our data indicate that this flow cytometric method is useful to study gene flow and assessment of transgene containment.
Galanzha, Ekaterina I.; Sarimollaoglu, Mustafa; Nedosekin, Dmitry A.; Keyrouz, Salah G.; Mehta, Jawahar L.; Zharov, Vladimir P.
2012-01-01
Conventional photothermal (PT) and photoacousic (PA) imaging, spectroscopy, and cytometry are preferentially based on positive PT/PA effects, when signals are above background. Here, we introduce PT/PA technique based on detection of negative signals below background. Among various new applications, we propose label-free in vivo flow cytometry of circulating clots. No method has been developed for the early detection of clots of different compositions as a source of severe thromboembolisms including ischemia at strokes and myocardial dysfunction at heart attack. When a low-absorbing, platelet-rich clot passes a laser-irradiated vessel volume, a transient decrease in local absorption results in an ultrasharp negative PA hole in blood background. Using this phenomenon alone or in combination with positive contrasts, we demonstrated identification of white, red and mixed clots on a mouse model of myocardial infarction and human blood. The concentration and size of clots were measured with threshold down to few clots in the entire circulation with size as low as 20 µm. This multiparameter diagnostic platform using portable personal high-speed flow cytometer with negative dynamic contrast mode has potential to real-time defining risk factors for cardiovascular diseases, and for prognosis and prevention of stroke or use clot count as a marker of therapy efficacy. Possibility for label-free detection of platelets, leukocytes, tumor cells or targeting them by negative PA probes (e.g., nonabsorbing beads or bubbles) is also highlighted. PMID:21976458
Assessment of cell concentration and viability of isolated hepatocytes using flow cytometry.
Wigg, Alan J; Phillips, John W; Wheatland, Loretta; Berry, Michael N
2003-06-01
The assessment of cell concentration and viability of freshly isolated hepatocyte preparations has been traditionally performed using manual counting with a Neubauer counting chamber and staining for trypan blue exclusion. Despite the simple and rapid nature of this assessment, concerns about the accuracy of these methods exist. Simple flow cytometry techniques which determine cell concentration and viability are available yet surprisingly have not been extensively used or validated with isolated hepatocyte preparations. We therefore investigated the use of flow cytometry using TRUCOUNT Tubes and propidium iodide staining to measure cell concentration and viability of isolated rat hepatocytes in suspension. Analysis using TRUCOUNT Tubes provided more accurate and reproducible measurement of cell concentration than manual cell counting. Hepatocyte viability, assessed using propidium iodide, correlated more closely than did trypan blue exclusion with all indicators of hepatocyte integrity and function measured (lactate dehydrogenase leakage, cytochrome p450 content, cellular ATP concentration, ammonia and lactate removal, urea and albumin synthesis). We conclude that flow cytometry techniques can be used to measure cell concentration and viability of isolated hepatocyte preparations. The techniques are simple, rapid, and more accurate than manual cell counting and trypan blue staining and the results are not affected by protein-containing media.
[Flow cytometry in datecting lymph node micrometastasis in colorectal cancer].
Sun, Q; Ding, Y; Zhang, J
2001-01-25
To study the methodology and significance of flow cytometry in detecting lymph node micrometastasis of colorectal cancer. One hundred sixty-two cellular suspensions were prepared with lymph nodes which were resected radically on 25 patients with colorectal cancer and in which no cancer cells were found by HE staining. Different concentrations of cultured Lovo colorectal cancer cells were added into the celular suspension prepared from lymph node tissue of persons without colorectal cancer in order to prepare a control model. Dual staining with CK/FTTC and PI was made to the sedimetns from those 2 kinds of suspension. Flow cytometry was used to detect cancer cells. An ideal correlation was obtained between the detection value and the theoretical value of cancer cells in the specimen suspensions and control models (r = 0.097 6) with a sensitivity rate of 10/10(5). Cancer cells were detected from 7 out of the 25 patients and 30 of the 162 cellular suspensions. The detection rate was correlated with the size and infiltrating depth of the cancer. Flow cytometry is a reliable, rapid, and quantitative method for detecting lymph node micrometastasis in colorectal cancer.
Assessing FRET using spectral techniques.
Leavesley, Silas J; Britain, Andrea L; Cichon, Lauren K; Nikolaev, Viacheslav O; Rich, Thomas C
2013-10-01
Förster resonance energy transfer (FRET) techniques have proven invaluable for probing the complex nature of protein-protein interactions, protein folding, and intracellular signaling events. These techniques have traditionally been implemented with the use of one or more fluorescence band-pass filters, either as fluorescence microscopy filter cubes, or as dichroic mirrors and band-pass filters in flow cytometry. In addition, new approaches for measuring FRET, such as fluorescence lifetime and acceptor photobleaching, have been developed. Hyperspectral techniques for imaging and flow cytometry have also shown to be promising for performing FRET measurements. In this study, we have compared traditional (filter-based) FRET approaches to three spectral-based approaches: the ratio of acceptor-to-donor peak emission, linear spectral unmixing, and linear spectral unmixing with a correction for direct acceptor excitation. All methods are estimates of FRET efficiency, except for one-filter set and three-filter set FRET indices, which are included for consistency with prior literature. In the first part of this study, spectrofluorimetric data were collected from a CFP-Epac-YFP FRET probe that has been used for intracellular cAMP measurements. All comparisons were performed using the same spectrofluorimetric datasets as input data, to provide a relevant comparison. Linear spectral unmixing resulted in measurements with the lowest coefficient of variation (0.10) as well as accurate fits using the Hill equation. FRET efficiency methods produced coefficients of variation of less than 0.20, while FRET indices produced coefficients of variation greater than 8.00. These results demonstrate that spectral FRET measurements provide improved response over standard, filter-based measurements. Using spectral approaches, single-cell measurements were conducted through hyperspectral confocal microscopy, linear unmixing, and cell segmentation with quantitative image analysis. Results from these studies confirmed that spectral imaging is effective for measuring subcellular, time-dependent FRET dynamics and that additional fluorescent signals can be readily separated from FRET signals, enabling multilabel studies of molecular interactions. © 2013 International Society for Advancement of Cytometry. Copyright © 2013 International Society for Advancement of Cytometry.
Label-free in vivo flow cytometry in zebrafish using two-photon autofluorescence imaging.
Zeng, Yan; Xu, Jin; Li, Dong; Li, Li; Wen, Zilong; Qu, Jianan Y
2012-07-01
We demonstrate a label-free in vivo flow cytometry in zebrafish blood vessels based on two-photon excited autofluorescence imaging. The major discovery in this work is the strong autofluorescence emission from the plasma in zebrafish blood. The plasma autofluorescence provides excellent contrast for visualizing blood vessels and counting blood cells. In addition, the cellular nicotinamide adenine dinucleotide autofluorescence enables in vivo imaging and counting of white blood cells (neutrophils).
Williams, Anna J; Cooper, Willie M; Summage-West, Christine V; Sims, Lillie M; Woodruff, Robert; Christman, Jessica; Moskal, Ted J; Ramsaroop, Shawn; Sutherland, John B; Alusta, Pierre; Wilkes, Jon G; Buzatu, Dan A
2015-12-23
The Bacteriological Analytical Manual (BAM) method currently used by the United States Food and Drug Administration (FDA) to detect Escherichia coli O157:H7 in spinach was systematically compared to a new flow cytometry based method. This Food and Drug Administration (FDA) level 2 external laboratory validation study was designed to determine the latter method's sensitivity and speed for analysis of this pathogen in raw spinach. Detection of target cell inoculations with a low cell count is critical, since enterohemorrhagic strains of E. coli require an infective dose of as few as 10 cells (Schmid-Hempel and Frank, 2007). Although, according to the FDA, the infectious dose is unknown (Food and Drug Administration, 1993). Therefore, the inoculation level into the spinach, a total of 2.0±2.6 viable E. coli O157 cells, was specified to yield between 25% and 75% detection by the new method, out of 20 samples (10 positives and 10 negatives). This criterion was met in that the new method detected 60% of the nominally positive samples; the corresponding sensitivity of the reference method was 50%. For both methods the most likely explanation for false negatives was that no viable cells were actually introduced into the sample. In this validation study, the flow cytometry method was equal to the BAM in sensitivity and far superior in speed. Published by Elsevier B.V.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ozanich, Rich M.; Antolick, Kathryn C.; Bruckner-Lea, Cindy J.
2007-09-15
Automated devices and methods for biological sample preparation often utilize surface functionalized microbeads (superparamagnetic or non-magnetic) to allow capture, purification and pre-concentration of trace amounts of proteins, cells, or nucleic acids (DNA/RNA) from complex samples. We have developed unique methods and hardware for trapping either magnetic or non-magnetic functionalized beads that allow samples and reagents to be efficiently perfused over a micro-column of beads. This approach yields enhanced mass transport and up to 5-fold improvements in assay sensitivity or speed, dramatically improving assay capability relative to assays conducted in more traditional “batch modes” (i.e., in tubes or microplate wells). Summarymore » results are given that highlight the analytical performance improvements obtained for automated microbead processing systems utilizing novel microbead trap/flow-cells for various applications, including: 1) simultaneous capture of multiple cytokines using an antibody-coupled polystyrene bead assay with subsequent flow cytometry detection; 2) capture of nucleic acids using oligonucleotide coupled polystyrene beads with flow cytometry detection; and 3) capture of Escherichia coli 0157:H7 (E. coli) from 50 mL sample volumes using antibody-coupled superparamagnetic microbeads with subsequent culturing to assess capture efficiency.« less
Hsiao, Chiaowen; Liu, Mengya; Stanton, Rick; McGee, Monnie; Qian, Yu; Scheuermann, Richard H
2016-01-01
Flow cytometry (FCM) is a fluorescence-based single-cell experimental technology that is routinely applied in biomedical research for identifying cellular biomarkers of normal physiological responses and abnormal disease states. While many computational methods have been developed that focus on identifying cell populations in individual FCM samples, very few have addressed how the identified cell populations can be matched across samples for comparative analysis. This article presents FlowMap-FR, a novel method for cell population mapping across FCM samples. FlowMap-FR is based on the Friedman-Rafsky nonparametric test statistic (FR statistic), which quantifies the equivalence of multivariate distributions. As applied to FCM data by FlowMap-FR, the FR statistic objectively quantifies the similarity between cell populations based on the shapes, sizes, and positions of fluorescence data distributions in the multidimensional feature space. To test and evaluate the performance of FlowMap-FR, we simulated the kinds of biological and technical sample variations that are commonly observed in FCM data. The results show that FlowMap-FR is able to effectively identify equivalent cell populations between samples under scenarios of proportion differences and modest position shifts. As a statistical test, FlowMap-FR can be used to determine whether the expression of a cellular marker is statistically different between two cell populations, suggesting candidates for new cellular phenotypes by providing an objective statistical measure. In addition, FlowMap-FR can indicate situations in which inappropriate splitting or merging of cell populations has occurred during gating procedures. We compared the FR statistic with the symmetric version of Kullback-Leibler divergence measure used in a previous population matching method with both simulated and real data. The FR statistic outperforms the symmetric version of KL-distance in distinguishing equivalent from nonequivalent cell populations. FlowMap-FR was also employed as a distance metric to match cell populations delineated by manual gating across 30 FCM samples from a benchmark FlowCAP data set. An F-measure of 0.88 was obtained, indicating high precision and recall of the FR-based population matching results. FlowMap-FR has been implemented as a standalone R/Bioconductor package so that it can be easily incorporated into current FCM data analytical workflows. © The Authors. Published by Wiley Periodicals, Inc. on behalf of ISAC.
de Castro Zacche-Tonini, Aline; Fonseca, Giuliana Schmidt França; de Jesus, Laura Néspoli Nassar Pansini; Barros, Geisa Baptista; Coelho-Dos-Reis, Jordana Grazziela Alves; Béla, Samantha Ribeiro; Machado, Anderson Silva; Carneiro, Ana Carolina Aguiar Vasconcelos; Andrade, Gláucia Manzan Queiroz; Vasconcelos-Santos, Daniel Vitor; Januário, José Nélio; Teixeira-Carvalho, Andréa; Vitor, Ricardo Wagner Almeida; Ferro, Eloísa Amália Vieira; Mineo, José Roberto; Martins-Filho, Olindo Assis; Lemos, Elenice Moreira
2017-12-01
The aim of this study was to evaluate the performance of conventional serology (Q-Preven™ and ELFAVIDAS™) and flow cytometry-based serologic tools for early serologic diagnosis of congenital toxoplasmosis. The study groups included prospectively confirmed cases of congenital toxoplasmosis (TOXO=88) and age-matching non-infected controls (NI=15).The results demonstrated that all samples tested positive/indeterminate for anti-T. gondii IgM screening at birth using air-dried whole blood samples. Serum samples collected at 30-45days after birth tested positive for ELFAVIDAS™ IgG in both groups. While all NI tested negative for ELFAVIDAS™ IgM and IgA, only 78% and 36% of TOXO tested positive for IgM and IgA, respectively. Flow cytometry-based anti-T. gondii IgM, IgA and IgG reactivity displayed moderate performance with low sensitivity (47.6%, 72.6% and 75.0%, respectively). Regardless the remarkable specificity of IgG1, IgG2 and IgG3 subclasses for early diagnosis, weak or moderate specificity was observed (Se=73.9%, 60.2% and 83.0%, respectively). The analysis of IgG avidity indices (AI) demonstrated the highest performance among the flow cytometry-based methods (Se=96.6%; Sp=93.3%), underscoring the low avidity index (AI<60%) within TOXO (97.0%) in contrast with the high avidity index (AI>60%) in NI (93%). Analysis of anti-T. gondii IgG and IgG3 reactivity for mother:infant paired samples may represent a relevant complementary tests for early diagnosis. In conclusion, a feasible high-standard algorithm (Accuracy=97.1%) was proposed consisting of Q-Preven™ IgM screening at birth, followed by ELFAVIDAS™ IgM and flow cytometric IgG avidity analysis at 30-45days after birth as a high performance tool for early serological diagnosis of congenital toxoplasmosis. Copyright © 2017. Published by Elsevier B.V.
Enzymatic signal amplification for sensitive detection of intracellular antigens by flow cytometry.
Karkmann, U; Radbruch, A; Hölzel, V; Scheffold, A
1999-11-19
Flow cytometry is the method of choice for the analysis of single cells with respect to the expression of specific antigens. Antigens can be detected with specific antibodies either on the cell surface or within the cells, after fixation and permeabilization of the cell membrane. Using conventional fluorochrome-labeled antibodies several thousand antigens are required for clear-cut separation of positive and negative cells. More sensitive reagents, e.g., magnetofluorescent liposomes conjugated to specific antibodies permit the detection of less than 200 molecules per cell but cannot be used for the detection of intracellular antigens. Here, we describe an enzymatic amplification technique (intracellular tyramine-based signal amplification, ITSA) for the sensitive cytometric analysis of intracellular cytokines by immunofluorescence. This approach results in a 10 to 15-fold improvement of the signal-to-noise ratio compared to conventional fluorochrome labeled antibodies and permits the detection of as few as 300-400 intracellular antigens per cell.
Liu, Liping; Yin, Yan; Li, Fei; Malhotra, Charvi; Cheng, Jianguo
2017-06-01
Cellular responses to nerve injury play a central role in the pathogenesis of neuropathic pain. However, the analysis of site specific cellular responses to nerve injury and neuropathic pain is limited to immunohistochemistry staining with numerous limitations. We proposed to apply flow cytometry to overcome some of the limitations and developed two protocols for isolation of cells from small specimens of the sciatic nerve and dorsal root ganglion (DRG) in mice. RESULTS AND COMPARASION WITH EXISTING: methods We found that both the non-enzymatic and enzymatic approaches were highly effective in harvesting a sufficient number of cells for flow cytometry analysis in normal and pathological conditions. The total number of cells in the injury site of the sciatic and its DRGs increased significantly 14days after chronic constriction injury (CCI) of the sciatic nerve, compared to sham surgery control or the contralateral control. The enzymatic approach yielded a significantly higher total number of cells and CD45 negative cells, suggesting that this approach allows for harvest of more resident cells, compared to the non-enzymatic method. The percentage of CD45 + /CD11b + cells was significantly increased in the sciatic nerve but not in the DRG. These results were consistent with both protocols. We thus offer two simple and effective protocols that allow for application of flow cytometry to the investigation of cellular and molecular mechanisms of neuropathic pain. Copyright © 2017 Elsevier B.V. All rights reserved.
Identification and immunophenotypic characterization of normal and pathological mast cells.
Morgado, José Mário; Sánchez-Muñoz, Laura; Teodósio, Cristina; Escribano, Luís
2014-01-01
Mast cells (MCs) are secretory cells that are central players in human allergic disease and immune responses. With the exception of a few pathological situations, MCs are usually present at relatively low frequencies in most tissues. Since their first description, MCs in tissues were identified mostly using their morphological characteristics and their typical coloration when stained with aniline dyes. However, increasing availability of highly specific antibodies now permits the use of fluorescence-based flow cytometry as the method of choice for the quantification, characterization, and purification of cells in suspension. This technique allows for a rapid analysis of thousands of events and for the identification of cells present at frequencies as low as one event in 10(6) unwanted cells. This method also permits for simultaneous characterization of multiple antigens at a single-cell level, which is ideal in order to study rare populations of cells like MCs. Here we describe the basis of flow cytometry-based immunophenotyping applied to the study of MC. The protocol focuses on the study of human MCs present in body fluids (mainly bone marrow) but can easily be adapted to study MCs from other tissues and species.
Screening of Compounds Toxicity against Human Monocytic cell line-THP-1 by Flow Cytometry
Pick, Neora; Cameron, Scott; Arad, Dorit
2004-01-01
The worldwide rapid increase in bacterial resistance to numerous antibiotics requires on-going development of new drugs to enter the market. As the development of new antibiotics is lengthy and costly, early monitoring of compound's toxicity is essential in the development of novel agents. Our interest is in a rapid, simple, high throughput screening method to assess cytotoxicity induced by potential agents. Some intracellular pathogens, such as Mycobacterium tuberculosis primary site of infection is human alveolar macrophages. Thus, evaluation of candidate drugs for macrophage toxicity is crucial. Protocols for high throughput drug toxicity screening of macrophages using flow cytometry are lacking in the literature. For this application we modified a preexisting technique, propidium iodide (PI) exclusion staining and utilized it for rapid toxicity tests. Samples were prepared in 96 well plates and analyzed by flow cytometry, which allowed for rapid, inexpensive and precise assessment of compound's toxicity associated with cell death. PMID:15472722
Cosma, Georgina; McArdle, Stéphanie E; Reeder, Stephen; Foulds, Gemma A; Hood, Simon; Khan, Masood; Pockley, A Graham
2017-01-01
Determining whether an asymptomatic individual with Prostate-Specific Antigen (PSA) levels below 20 ng ml -1 has prostate cancer in the absence of definitive, biopsy-based evidence continues to present a significant challenge to clinicians who must decide whether such individuals with low PSA values have prostate cancer. Herein, we present an advanced computational data extraction approach which can identify the presence of prostate cancer in men with PSA levels <20 ng ml -1 on the basis of peripheral blood immune cell profiles that have been generated using multi-parameter flow cytometry. Statistical analysis of immune phenotyping datasets relating to the presence and prevalence of key leukocyte populations in the peripheral blood, as generated from individuals undergoing routine tests for prostate cancer (including tissue biopsy) using multi-parametric flow cytometric analysis, was unable to identify significant relationships between leukocyte population profiles and the presence of benign disease (no prostate cancer) or prostate cancer. By contrast, a Genetic Algorithm computational approach identified a subset of five flow cytometry features ( CD 8 + CD 45 RA - CD 27 - CD 28 - ( CD 8 + Effector Memory cells); CD 4 + CD 45 RA - CD 27 - CD 28 - ( CD 4 + Terminally Differentiated Effector Memory Cells re-expressing CD45RA); CD 3 - CD 19 + (B cells); CD 3 + CD 56 + CD 8 + CD 4 + (NKT cells)) from a set of twenty features, which could potentially discriminate between benign disease and prostate cancer. These features were used to construct a prostate cancer prediction model using the k-Nearest-Neighbor classification algorithm. The proposed model, which takes as input the set of flow cytometry features, outperformed the predictive model which takes PSA values as input. Specifically, the flow cytometry-based model achieved Accuracy = 83.33%, AUC = 83.40%, and optimal ROC points of FPR = 16.13%, TPR = 82.93%, whereas the PSA-based model achieved Accuracy = 77.78%, AUC = 76.95%, and optimal ROC points of FPR = 29.03%, TPR = 82.93%. Combining PSA and flow cytometry predictors achieved Accuracy = 79.17%, AUC = 78.17% and optimal ROC points of FPR = 29.03%, TPR = 85.37%. The results demonstrate the value of computational intelligence-based approaches for interrogating immunophenotyping datasets and that combining peripheral blood phenotypic profiling with PSA levels improves diagnostic accuracy compared to using PSA test alone. These studies also demonstrate that the presence of cancer is reflected in changes in the peripheral blood immune phenotype profile which can be identified using computational analysis and interpretation of complex flow cytometry datasets.
Tracking protein aggregation and mislocalization in cells with flow cytometry.
Ramdzan, Yasmin M; Polling, Saskia; Chia, Cheryl P Z; Ng, Ivan H W; Ormsby, Angelique R; Croft, Nathan P; Purcell, Anthony W; Bogoyevitch, Marie A; Ng, Dominic C H; Gleeson, Paul A; Hatters, Danny M
2012-03-18
We applied pulse-shape analysis (PulSA) to monitor protein localization changes in mammalian cells by flow cytometry. PulSA enabled high-throughput tracking of protein aggregation, translocation from the cytoplasm to the nucleus and trafficking from the plasma membrane to the Golgi as well as stress-granule formation. Combining PulSA with tetracysteine-based oligomer sensors in a cell model of Huntington's disease enabled further separation of cells enriched with monomers, oligomers and inclusion bodies.
Mobile flow cytometer for mHealth.
Balsam, Joshua; Bruck, Hugh Alan; Rasooly, Avraham
2015-01-01
Flow cytometry is used for cell counting and analysis in numerous clinical and environmental applications. However flow cytometry is not used in mHealth mainly because current flow cytometers are large, expensive, power-intensive devices designed to operate in a laboratory. Their design results in a lack of portability and makes them unsuitable for mHealth applications. Another limitation of current technology is the low volumetric throughput rates that are not suitable for rapid detection of rare cells.To address these limitations, we describe here a novel, low-cost, mobile flow cytometer based on wide-field imaging with a webcam for large volume and high throughput fluorescence detection of rare cells as a simulation for circulating tumor cells (CTCs) detection. The mobile flow cytometer uses a commercially available webcam capable of 187 frames per second video capture at a resolution of 320 × 240 pixels. For fluorescence detection, a 1 W 450 nm blue laser is used for excitation of Syto-9 fluorescently stained cells detected at 535 nm. A wide-field flow cell was developed for large volume analysis that allows for the linear velocity of target cells to be lower than in conventional hydrodynamic focusing flow cells typically used in cytometry. The mobile flow cytometer was found to be capable of detecting low concentrations at flow rates of 500 μL/min, suitable for rare cell detection in large volumes. The simplicity and low cost of this device suggests that it may have a potential clinical use for mHealth flow cytometry for resource-poor settings associated with global health.
Vo, Kieuhoa T.; Edwards, Jeremy V.; Epling, C. Lorrie; Sinclair, Elizabeth; Hawkins, Douglas S.; Grier, Holcombe E.; Janeway, Katherine A.; Barnette, Phillip; McIlvaine, Elizabeth; Krailo, Mark D.; Barkauskas, Donald A.; Matthay, Katherine K.; Womer, Richard B.; Gorlick, Richard G.; Lessnick, Stephen L.; Mackall, Crystal L.; DuBois, Steven G.
2016-01-01
Purpose Flow cytometry and RT-PCR can detect occult Ewing sarcoma (ES) cells in the blood and bone marrow (BM). These techniques were used to evaluate the prognostic significance of micrometastatic disease in ES. Experimental Design Newly diagnosed patients with ES were enrolled on two prospective multi-center studies. In the flow cytometry cohort, patients were defined as “positive” for BM micrometastatic disease if their CD99+/CD45− values were above the upper limit in 22 control patients. In the PCR cohort, RT-PCR on blood or BM samples classified the patients as “positive” or “negative” for EWSR1/FLI1 translocations. The association between micrometastatic disease burden with clinical features and outcome was assessed. Co-expression of IGF-1R on detected tumor cells was performed in a subset of flow cytometry samples. Results The median total BM CD99+CD45− percent was 0.0012% (range 0–1.10%) in the flow cytometry cohort, with 14/109 (12.8%) of ES patients defined as “positive.” In the PCR cohort, 19.6% (44/225) patients were “positive” for any EWSR1/FLI1 translocation in blood or BM. There were no differences in baseline clinical features or event-free or overall survival between patients classified as “positive” vs. “negative” by either method. CD99+CD45− cells had significantly higher IGF-1R expression compared to CD45+ hematopoietic cells (mean geometric mean fluorescence intensity 982.7 vs. 190.9; p<0.001). Conclusion The detection of micrometastatic disease at initial diagnosis by flow cytometry or RT-PCR is not associated with outcome in newly diagnosed patients with ES. Flow cytometry provides a tool to characterize occult micrometastatic tumor cells for proteins of interest. PMID:26861456
Flow Cytometry Data Preparation Guidelines for Improved Automated Phenotypic Analysis.
Jimenez-Carretero, Daniel; Ligos, José M; Martínez-López, María; Sancho, David; Montoya, María C
2018-05-15
Advances in flow cytometry (FCM) increasingly demand adoption of computational analysis tools to tackle the ever-growing data dimensionality. In this study, we tested different data input modes to evaluate how cytometry acquisition configuration and data compensation procedures affect the performance of unsupervised phenotyping tools. An analysis workflow was set up and tested for the detection of changes in reference bead subsets and in a rare subpopulation of murine lymph node CD103 + dendritic cells acquired by conventional or spectral cytometry. Raw spectral data or pseudospectral data acquired with the full set of available detectors by conventional cytometry consistently outperformed datasets acquired and compensated according to FCM standards. Our results thus challenge the paradigm of one-fluorochrome/one-parameter acquisition in FCM for unsupervised cluster-based analysis. Instead, we propose to configure instrument acquisition to use all available fluorescence detectors and to avoid integration and compensation procedures, thereby using raw spectral or pseudospectral data for improved automated phenotypic analysis. Copyright © 2018 by The American Association of Immunologists, Inc.
Separating the signal from the noise: Expanding flow cytometry into the sub-micron range.
Cytometry Part A Special Section: Separating the signal from the noise: Expanding flow cytometry into the sub-micron range. The current Cytometry Part A Special Section presents three studies that utilize cytometers to study sub-micron particles. The three studies involve the 1...
FlowCam: Quantification and Classification of Phytoplankton by Imaging Flow Cytometry.
Poulton, Nicole J
2016-01-01
The ability to enumerate, classify, and determine biomass of phytoplankton from environmental samples is essential for determining ecosystem function and their role in the aquatic community and microbial food web. Traditional micro-phytoplankton quantification methods using microscopic techniques require preservation and are slow, tedious and very laborious. The availability of more automated imaging microscopy platforms has revolutionized the way particles and cells are detected within their natural environment. The ability to examine cells unaltered and without preservation is key to providing more accurate cell concentration estimates and overall phytoplankton biomass. The FlowCam(®) is an imaging cytometry tool that was originally developed for use in aquatic sciences and provides a more rapid and unbiased method for enumerating and classifying phytoplankton within diverse aquatic environments.
Futamura, Koji; Sekino, Masashi; Hata, Akihiro; Ikebuchi, Ryoyo; Nakanishi, Yasutaka; Egawa, Gyohei; Kabashima, Kenji; Watanabe, Takeshi; Furuki, Motohiro
2015-01-01
Abstract Flow cytometric analysis with multicolor fluoroprobes is an essential method for detecting biological signatures of cells. Here, we present a new full‐spectral flow cytometer (spectral‐FCM). Unlike conventional flow cytometer, this spectral‐FCM acquires the emitted fluorescence for all probes across the full‐spectrum from each cell with 32 channels sequential PMT unit after dispersion with prism, and extracts the signals of each fluoroprobe based on the spectral shape of each fluoroprobe using unique algorithm in high speed, high sensitive, accurate, automatic and real‐time. The spectral‐FCM detects the continuous changes in emission spectra from green to red of the photoconvertible protein, KikGR with high‐spectral resolution and separates spectrally‐adjacent fluoroprobes, such as FITC (Emission peak (Em) 519 nm) and EGFP (Em 507 nm). Moreover, the spectral‐FCM can measure and subtract autofluorescence of each cell providing increased signal‐to‐noise ratios and improved resolution of dim samples, which leads to a transformative technology for investigation of single cell state and function. These advances make it possible to perform 11‐color fluorescence analysis to visualize movement of multilinage immune cells by using KikGR‐expressing mice. Thus, the novel spectral flow cytometry improves the combinational use of spectrally‐adjacent various FPs and multicolor fluorochromes in metabolically active cell for the investigation of not only the immune system but also other research and clinical fields of use. © 2015 The Authors. Cytometry Part A Published by Wiley Periodicals, Inc. on behalf of ISAC PMID:26217952
Minimal Residual Disease Evaluation in Childhood Acute Lymphoblastic Leukemia: An Economic Analysis.
2016-01-01
Minimal residual disease (MRD) testing by higher performance techniques such as flow cytometry and polymerase chain reaction (PCR) can be used to detect the proportion of remaining leukemic cells in bone marrow or peripheral blood during and after the first phases of chemotherapy in children with acute lymphoblastic leukemia (ALL). The results of MRD testing are used to reclassify these patients and guide changes in treatment according to their future risk of relapse. We conducted a systematic review of the economic literature, cost-effectiveness analysis, and budget-impact analysis to ascertain the cost-effectiveness and economic impact of MRD testing by flow cytometry for management of childhood precursor B-cell ALL in Ontario. A systematic literature search (1998-2014) identified studies that examined the incremental cost-effectiveness of MRD testing by either flow cytometry or PCR. We developed a lifetime state-transition (Markov) microsimulation model to quantify the cost-effectiveness of MRD testing followed by risk-directed therapy to no MRD testing and to estimate its marginal effect on health outcomes and on costs. Model input parameters were based on the literature, expert opinion, and data from the Pediatric Oncology Group of Ontario Networked Information System. Using predictions from our Markov model, we estimated the 1-year cost burden of MRD testing versus no testing and forecasted its economic impact over 3 and 5 years. In a base-case cost-effectiveness analysis, compared with no testing, MRD testing by flow cytometry at the end of induction and consolidation was associated with an increased discounted survival of 0.0958 quality-adjusted life-years (QALYs) and increased discounted costs of $4,180, yielding an incremental cost-effectiveness ratio (ICER) of $43,613/QALY gained. After accounting for parameter uncertainty, incremental cost-effectiveness of MRD testing was associated with an ICER of $50,249/QALY gained. In the budget-impact analysis, the 1-year cost expenditure for MRD testing by flow cytometry in newly diagnosed patients with precursor B-cell ALL was estimated at $340,760. We forecasted that the province would have to pay approximately $1.3 million over 3 years and $2.4 million over 5 years for MRD testing by flow cytometry in this population. Compared with no testing, MRD testing by flow cytometry in newly diagnosed patients with precursor B-cell ALL represents good value for money at commonly used willingness-to-pay thresholds of $50,000/QALY and $100,000/QALY.
Mathaes, Roman; Winter, Gerhard; Engert, Julia; Besheer, Ahmed
2013-09-10
Non-spherical micro- and nanoparticles have recently gained considerable attention due to their surprisingly different interaction with biological systems compared to their spherical counterparts, opening new opportunities for drug delivery and vaccination. Up till now, electron microscopy is the only method to quantitatively identify the critical quality attributes (CQAs) of non-spherical particles produced by film-stretching; namely size, morphology and the quality of non-spherical particles (degree of contamination with spherical ones). However, electron microscopy requires expensive instrumentation, demanding sample preparation and non-trivial image analysis. To circumvent these drawbacks, the ability of different particle analysis methods to quantitatively identify the CQA of spherical and non-spherical poly(1-phenylethene-1,2-diyl (polystyrene) particles over a wide size range (40 nm, 2 μm and 10 μm) was investigated. To this end, light obscuration, image-based analysis methods (Microflow imaging, MFI, and Vi-Cell XR Coulter Counter) and flow cytometry were used to study particles in the micron range, while asymmetric flow field fractionation (AF4) coupled to multi-angle laser scattering (MALS) and quasi elastic light scattering (QELS) was used for particles in the nanometer range, and all measurements were benchmarked against electron microscopy. Results show that MFI can reliably identify particle size and aspect ratios of the 10 μm particles, but not the 2 μm ones. Meanwhile, flow cytometry was able to differentiate between spherical and non-spherical 10 or 2 μm particles, and determine the amount of impurities in the sample. As for the nanoparticles, AF4 coupled to MALS and QELS allowed the measurement of the geometric (rg) and hydrodynamic (rh) radii of the particles, as well as their shape factors (rg/rh), confirming their morphology. While this study shows the utility of MFI, flow cytometry and AF4 for quantitative evaluation of the CQA of non-spherical particles over a wide size range, the limitations of the methods are discussed. The use of orthogonal characterization methods can provide a complete picture about the CQA of non-spherical particles over a wide size range. Copyright © 2013 Elsevier B.V. All rights reserved.
Buckle, Tessa; van der Wal, Steffen; van Malderen, Stijn J.M.; Müller, Larissa; Kuil, Joeri; van Unen, Vincent; Peters, Ruud J.B.; van Bemmel, Margaretha E.M.; McDonnell, Liam A.; Velders, Aldrik H.; Koning, Frits; Vanhaeke, Frank; van Leeuwen, Fijs W. B.
2017-01-01
Background: Development of theranostic concepts that include inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation ICP-MS (LA-ICP-MS) imaging can be hindered by the lack of a direct comparison to more standardly used methods for in vitro and in vivo evaluation; e.g. fluorescence or nuclear medicine. In this study a bimodal (or rather, hybrid) tracer that contains both a fluorescent dye and a chelate was used to evaluate the existence of a direct link between mass spectrometry (MS) and in vitro and in vivo molecular imaging findings using fluorescence and radioisotopes. At the same time, the hybrid label was used to determine whether the use of a single isotope label would allow for MS-based diagnostics. Methods: A hybrid label that contained both a DTPA chelate (that was coordinated with either 165Ho or 111In) and a Cy5 fluorescent dye was coupled to the chemokine receptor 4 (CXCR4) targeting peptide Ac-TZ14011 (hybrid-Cy5-Ac-TZ4011). This receptor targeting tracer was used to 1) validate the efficacy of (165Ho-based) mass-cytometry in determining the receptor affinity via comparison with fluorescence-based flow cytometry (Cy5), 2) evaluate the microscopic binding pattern of the tracer in tumor cells using both fluorescence confocal imaging (Cy5) and LA-ICP-MS-imaging (165Ho), 3) compare in vivo biodistribution patterns obtained with ICP-MS (165Ho) and radiodetection (111In) after intravenous administration of hybrid-Cy5-Ac-TZ4011 in tumor-bearing mice. Finally, LA-ICP-MS-imaging (165Ho) was linked to fluorescence-based analysis of excised tissue samples (Cy5). Results: Analysis with both mass-cytometry and flow cytometry revealed a similar receptor affinity, respectively 352 ± 141 nM and 245 ± 65 nM (p = 0.08), but with a much lower detection sensitivity for the first modality. In vitro LA-ICP-MS imaging (165Ho) enabled clear discrimination between CXCR4 positive and negative cells, but fluorescence microscopy was required to determine the intracellular distribution. In vivo biodistribution patterns obtained with ICP-MS (165Ho) and radiodetection (111In) of the hybrid peptide were shown to be similar. Assessment of tracer distribution in excised tissues revealed the location of tracer uptake with both LA-ICP-MS-imaging and fluorescence imaging. Conclusion: Lanthanide-isotope chelation expands the scope of fluorescent/radioactive hybrid tracers to include MS-based analytical tools such as mass-cytometry, ICP-MS and LA-ICP-MS imaging in molecular pathology. In contradiction to common expectations, MS detection using a single chelate imaging agent was shown to be feasible, enabling a direct link between nuclear medicine-based imaging and theranostic methods. PMID:28255355
FuGEFlow: data model and markup language for flow cytometry.
Qian, Yu; Tchuvatkina, Olga; Spidlen, Josef; Wilkinson, Peter; Gasparetto, Maura; Jones, Andrew R; Manion, Frank J; Scheuermann, Richard H; Sekaly, Rafick-Pierre; Brinkman, Ryan R
2009-06-16
Flow cytometry technology is widely used in both health care and research. The rapid expansion of flow cytometry applications has outpaced the development of data storage and analysis tools. Collaborative efforts being taken to eliminate this gap include building common vocabularies and ontologies, designing generic data models, and defining data exchange formats. The Minimum Information about a Flow Cytometry Experiment (MIFlowCyt) standard was recently adopted by the International Society for Advancement of Cytometry. This standard guides researchers on the information that should be included in peer reviewed publications, but it is insufficient for data exchange and integration between computational systems. The Functional Genomics Experiment (FuGE) formalizes common aspects of comprehensive and high throughput experiments across different biological technologies. We have extended FuGE object model to accommodate flow cytometry data and metadata. We used the MagicDraw modelling tool to design a UML model (Flow-OM) according to the FuGE extension guidelines and the AndroMDA toolkit to transform the model to a markup language (Flow-ML). We mapped each MIFlowCyt term to either an existing FuGE class or to a new FuGEFlow class. The development environment was validated by comparing the official FuGE XSD to the schema we generated from the FuGE object model using our configuration. After the Flow-OM model was completed, the final version of the Flow-ML was generated and validated against an example MIFlowCyt compliant experiment description. The extension of FuGE for flow cytometry has resulted in a generic FuGE-compliant data model (FuGEFlow), which accommodates and links together all information required by MIFlowCyt. The FuGEFlow model can be used to build software and databases using FuGE software toolkits to facilitate automated exchange and manipulation of potentially large flow cytometry experimental data sets. Additional project documentation, including reusable design patterns and a guide for setting up a development environment, was contributed back to the FuGE project. We have shown that an extension of FuGE can be used to transform minimum information requirements in natural language to markup language in XML. Extending FuGE required significant effort, but in our experiences the benefits outweighed the costs. The FuGEFlow is expected to play a central role in describing flow cytometry experiments and ultimately facilitating data exchange including public flow cytometry repositories currently under development.
Candidiasis and the impact of flow cytometry on antifungal drug discovery.
Ku, Tsun Sheng N; Bernardo, Stella; Walraven, Carla J; Lee, Samuel A
2017-11-01
Invasive candidiasis continues to be associated with significant morbidity and mortality as well as substantial health care costs nationally and globally. One of the contributing factors is the development of resistance to antifungal agents that are already in clinical use. Moreover, there are known treatment limitations with all of the available antifungal agents. Since traditional techniques in novel drug discovery are time consuming, high-throughput screening using flow cytometry presents as a potential tool to identify new antifungal agents that would be useful in the management of these patients. Areas covered: In this review, the authors discuss the use of automated high-throughput screening assays based upon flow cytometry to identify potential antifungals from a library comprised of a large number of bioactive compounds. They also review studies that employed the use of this research methodology that has identified compounds with antifungal activity. Expert opinion: High-throughput screening using flow cytometry has substantially decreased the processing time necessary for screening thousands of compounds, and has helped enhance our understanding of fungal pathogenesis. Indeed, the authors see this technology as a powerful tool to help scientists identify new antifungal agents that can be added to the clinician's arsenal in their fight against invasive candidiasis.
Wang, Youji; Hu, Menghong; Chiang, M W L; Shin, P K S; Cheung, S G
2012-03-01
The green-lipped mussel Perna viridis is distributed widely in the estuarine and coastal areas of the Indo-Pacific region and extensively cultured as an inexpensive protein source. Morphology and immunological activities of hemocytes of P. viridis were investigated using flow cytometry and light and electron microscopy. Three major types of hemocytes were identified in the hemolymph, including dense-granulocyte, semi-granulocyte (small and large size) and hyalinocyte. Other hemocytes, which occurred in low numbers, included granulocytes with different electron-dense/lucent granules and hemoblast-like cells. Based on flow cytometry, two subpopulations were identified. Granulocytes were larger cells, and the more abundant, containing numerous granules in the cytoplasm, and hyalinocytes were the smaller and less abundant with the fewest granules. Flow cytometry revealed that the granulocytes were more active in cell phagocytosis, contained the higher lysosomal content, and showed higher esterase activity and reactive oxygen species (ROS) generation compared with hyalinocytes. Immune functions assessed by the flow cytometry indicated that the granulocytes were the main hemocytes involved in the cellular defence in P. viridis. Copyright © 2011. Published by Elsevier Ltd.
Femtosecond laser fabrication of fiber based optofluidic platform for flow cytometry applications
NASA Astrophysics Data System (ADS)
Serhatlioglu, Murat; Elbuken, Caglar; Ortac, Bulend; Solmaz, Mehmet E.
2017-02-01
Miniaturized optofluidic platforms play an important role in bio-analysis, detection and diagnostic applications. The advantages of such miniaturized devices are extremely low sample requirement, low cost development and rapid analysis capabilities. Fused silica is advantageous for optofluidic systems due to properties such as being chemically inert, mechanically stable, and optically transparent to a wide spectrum of light. As a three dimensional manufacturing method, femtosecond laser scanning followed by chemical etching shows great potential to fabricate glass based optofluidic chips. In this study, we demonstrate fabrication of all-fiber based, optofluidic flow cytometer in fused silica glass by femtosecond laser machining. 3D particle focusing was achieved through a straightforward planar chip design with two separately fabricated fused silica glass slides thermally bonded together. Bioparticles in a fluid stream encounter with optical interrogation region specifically designed to allocate 405nm single mode fiber laser source and two multi-mode collection fibers for forward scattering (FSC) and side scattering (SSC) signals detection. Detected signal data collected with oscilloscope and post processed with MATLAB script file. We were able to count number of events over 4000events/sec, and achieve size distribution for 5.95μm monodisperse polystyrene beads using FSC and SSC signals. Our platform shows promise for optical and fluidic miniaturization of flow cytometry systems.
USDA-ARS?s Scientific Manuscript database
Recent developments in spectrally encoded microspheres (SEMs)-based technologies provide high multiplexing possibilities. Most SEMs-based assays required a flow cytometer with sophisticated fluidics and optics. The new imaging superparamagnetic SEMs-based platform transports SEMs with considerably ...
Aldridge, Andrew; Kouroupis, Dimitrios; Churchman, Sarah; English, Anne; Ingham, Eileen; Jones, Elena
2013-01-01
Background aims Mesenchymal stromal cells (MSCs) are regenerative and immuno-privileged cells that are used for both tissue regeneration and treatment of severe inflammation-related disease. For quality control of manufactured MSC batches in regard to mature fat cell contamination, a quantitative method for measuring adipogenesis is needed. Methods Four previously proposed methods were validated with the use of bone marrow (BM) MSCs during a 21-day in vitro assay. Oil red staining was scored semiquantitatively; peroxisome proliferator activated receptor-γ and fatty acid binding protein (FABP)4 transcripts were measured by quantitative real-time polymerase chain reaction; FABP4 protein accumulation was evaluated by flow cytometry; and Nile red/4′,6-diamidino-2-phenylindole (DAPI) ratios were measured in fluorescent microplate assay. Skin fibroblasts and MSCs from fat pad, cartilage and umbilical cord were used as controls. Results Oil red staining indicated considerable heterogeneity between BM donors and individual cells within the same culture. FABP4 transcript levels increased 100- to 5000-fold by day 21, with large donor variability observed. Flow cytometry revealed increasing intra-culture heterogeneity over time; more granular cells accumulated more FABP4 protein and Nile red fluorescence compared with less granular cells. Nile red increase in day-21 MSCs was ∼5- and 4-fold, measured by flow cytometry or microplate assay, respectively. MSC proliferation/apoptosis was accounted through the use of Nile red/DAPI ratios; adipogenesis levels in day-21 BM MSCs increased ∼13-fold, with significant correlations with oil red scoring observed for MSC from other sources. Conclusions Flow cytometry permits the study of MSC differentiation at the single-cell level and sorting more and less mature cells from mixed cell populations. The microplate assay with the use of the Nile red/DAPI ratio provides rapid quantitative measurements and could be used as a low-cost, high-throughput method to quality-control MSC batches from different tissue sources. PMID:23260089
Johnson, P E; Deromedi, A J; Lebaron, P; Catala, P; Havens, C; Pougnard, C
2007-09-01
To test Fountain Flow Cytometry (FFC) for the rapid and sensitive detection of Naegleria lovaniensis amoebae (an analogue for Naegleria fowleri) in natural river waters. Samples were incubated with one of two fluorescent labels to facilitate detection: ChemChrome V6, a viability indicator, and an R-phycoerytherin (RPE) immunolabel to detect N. lovaniensis specifically. The resulting aqueous sample was passed as a stream in front of a light-emitting diode, which excited the fluorescent labels. The fluorescence was detected with a digital camera as the sample flowed toward the imager. Detections of N. lovaniensis were made in inoculated samples of natural water from eight rivers in France and the United States. FFC enumeration yielded results that are consistent with other counting methods: solid-phase cytometry, flow cytometry, and hemocytometry, down to concentrations of 0.06 amoebae ml(-1), using a flow rate of 15 ml min(-1). This study supports the efficacy of using FFC for the detection of viable protozoa in natural waters and indicates that use of RPE illuminated at 530 nm and detected at 585 nm provides a satisfactory means of attenuating background. Because of the severe global public health issues with drinking water and sanitation, there is an urgent need to develop a technique for the real-time detection of viable pathogens in environmental samples at low concentrations. FFC addresses this need.
Scalable clustering algorithms for continuous environmental flow cytometry.
Hyrkas, Jeremy; Clayton, Sophie; Ribalet, Francois; Halperin, Daniel; Armbrust, E Virginia; Howe, Bill
2016-02-01
Recent technological innovations in flow cytometry now allow oceanographers to collect high-frequency flow cytometry data from particles in aquatic environments on a scale far surpassing conventional flow cytometers. The SeaFlow cytometer continuously profiles microbial phytoplankton populations across thousands of kilometers of the surface ocean. The data streams produced by instruments such as SeaFlow challenge the traditional sample-by-sample approach in cytometric analysis and highlight the need for scalable clustering algorithms to extract population information from these large-scale, high-frequency flow cytometers. We explore how available algorithms commonly used for medical applications perform at classification of such a large-scale, environmental flow cytometry data. We apply large-scale Gaussian mixture models to massive datasets using Hadoop. This approach outperforms current state-of-the-art cytometry classification algorithms in accuracy and can be coupled with manual or automatic partitioning of data into homogeneous sections for further classification gains. We propose the Gaussian mixture model with partitioning approach for classification of large-scale, high-frequency flow cytometry data. Source code available for download at https://github.com/jhyrkas/seaflow_cluster, implemented in Java for use with Hadoop. hyrkas@cs.washington.edu Supplementary data are available at Bioinformatics online. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
CytometryML and other data formats
NASA Astrophysics Data System (ADS)
Leif, Robert C.
2006-02-01
Cytology automation and research will be enhanced by the creation of a common data format. This data format would provide the pathology and research communities with a uniform way for annotating and exchanging images, flow cytometry, and associated data. This specification and/or standard will include descriptions of the acquisition device, staining, the binary representations of the image and list-mode data, the measurements derived from the image and/or the list-mode data, and descriptors for clinical/pathology and research. An international, vendor-supported, non-proprietary specification will allow pathologists, researchers, and companies to develop and use image capture/analysis software, as well as list-mode analysis software, without worrying about incompatibilities between proprietary vendor formats. Presently, efforts to create specifications and/or descriptions of these formats include the Laboratory Digital Imaging Project (LDIP) Data Exchange Specification; extensions to the Digital Imaging and Communications in Medicine (DICOM); Open Microscopy Environment (OME); Flowcyt, an extension to the present Flow Cytometry Standard (FCS); and CytometryML. The feasibility of creating a common data specification for digital microscopy and flow cytometry in a manner consistent with its use for medical devices and interoperability with both hospital information and picture archiving systems has been demonstrated by the creation of the CytometryML schemas. The feasibility of creating a software system for digital microscopy has been demonstrated by the OME. CytometryML consists of schemas that describe instruments and their measurements. These instruments include digital microscopes and flow cytometers. Optical components including the instruments' excitation and emission parts are described. The description of the measurements made by these instruments includes the tagged molecule, data acquisition subsystem, and the format of the list-mode and/or image data. Many of the CytometryML data-types are based on the Digital Imaging and Communications in Medicine (DICOM). Binary files for images and list-mode data have been created and read.
Malkassian, Anthony; Nerini, David; van Dijk, Mark A; Thyssen, Melilotus; Mante, Claude; Gregori, Gerald
2011-04-01
Analytical flow cytometry (FCM) is well suited for the analysis of phytoplankton communities in fresh and sea waters. The measurement of light scatter and autofluorescence properties of particles by FCM provides optical fingerprints, which enables different phytoplankton groups to be separated. A submersible version of the CytoSense flow cytometer (the CytoSub) has been designed for in situ autonomous sampling and analysis, making it possible to monitor phytoplankton at a short temporal scale and obtain accurate information about its dynamics. For data analysis, a manual clustering is usually performed a posteriori: data are displayed on histograms and scatterplots, and group discrimination is made by drawing and combining regions (gating). The purpose of this study is to provide greater objectivity in the data analysis by applying a nonmanual and consistent method to automatically discriminate clusters of particles. In other words, we seek for partitioning methods based on the optical fingerprints of each particle. As the CytoSense is able to record the full pulse shape for each variable, it quickly generates a large and complex dataset to analyze. The shape, length, and area of each curve were chosen as descriptors for the analysis. To test the developed method, numerical experiments were performed on simulated curves. Then, the method was applied and validated on phytoplankton cultures data. Promising results have been obtained with a mixture of various species whose optical fingerprints overlapped considerably and could not be accurately separated using manual gating. Copyright © 2011 International Society for Advancement of Cytometry.
Discovering cell types in flow cytometry data with random matrix theory
NASA Astrophysics Data System (ADS)
Shen, Yang; Nussenblatt, Robert; Losert, Wolfgang
Flow cytometry is a widely used experimental technique in immunology research. During the experiments, peripheral blood mononuclear cells (PBMC) from a single patient, labeled with multiple fluorescent stains that bind to different proteins, are illuminated by a laser. The intensity of each stain on a single cell is recorded and reflects the amount of protein expressed by that cell. The data analysis focuses on identifying specific cell types related to a disease. Different cell types can be identified by the type and amount of protein they express. To date, this has most often been done manually by labelling a protein as expressed or not while ignoring the amount of expression. Using a cross correlation matrix of stain intensities, which contains both information on the proteins expressed and their amount, has been largely ignored by researchers as it suffers from measurement noise. Here we present an algorithm to identify cell types in flow cytometry data which uses random matrix theory (RMT) to reduce noise in a cross correlation matrix. We demonstrate our method using a published flow cytometry data set. Compared with previous analysis techniques, we were able to rediscover relevant cell types in an automatic way. Department of Physics, University of Maryland, College Park, MD 20742.
Bono Jr., Michael S.; Garcia, Ravi D.; Sri-Jayantha, Dylan V.; Ahner, Beth A.; Kirby, Brian J.
2015-01-01
In this study, we cultured Chlorella vulgaris cells with a range of lipid contents, induced via nitrogen starvation, and characterized them via flow cytometry, with BODIPY 505/515 as a fluorescent lipid label, and liquid-state 1H NMR spectroscopy. In doing so, we demonstrate the utility of calibrating flow cytometric measurements of algal lipid content using triacylglyceride (TAG, also known as triacylglycerol or triglyceride) content per cell as measured via quantitative 1H NMR. Ensemble-averaged fluorescence of BODIPY-labeled cells was highly correlated with average TAG content per cell measured by bulk NMR, with a linear regression yielding a linear fit with r 2 = 0.9974. This correlation compares favorably to previous calibrations of flow cytometry protocols to lipid content measured via extraction, and calibration by NMR avoids the time and complexity that is generally required for lipid quantitation via extraction. Flow cytometry calibrated to a direct measurement of TAG content can be used to investigate the distribution of lipid contents for cells within a culture. Our flow cytometry measurements showed that Chlorella vulgaris cells subjected to nitrogen limitation exhibited higher mean lipid content but a wider distribution of lipid content that overlapped the relatively narrow distribution of lipid content for replete cells, suggesting that nitrogen limitation induces lipid accumulation in only a subset of cells. Calibration of flow cytometry protocols using direct in situ measurement of TAG content via NMR will facilitate rapid development of more precise flow cytometry protocols, enabling investigation of algal lipid accumulation for development of more productive algal biofuel feedstocks and cultivation protocols. PMID:26267664
Bono, Michael S; Garcia, Ravi D; Sri-Jayantha, Dylan V; Ahner, Beth A; Kirby, Brian J
2015-01-01
In this study, we cultured Chlorella vulgaris cells with a range of lipid contents, induced via nitrogen starvation, and characterized them via flow cytometry, with BODIPY 505/515 as a fluorescent lipid label, and liquid-state 1H NMR spectroscopy. In doing so, we demonstrate the utility of calibrating flow cytometric measurements of algal lipid content using triacylglyceride (TAG, also known as triacylglycerol or triglyceride) content per cell as measured via quantitative 1H NMR. Ensemble-averaged fluorescence of BODIPY-labeled cells was highly correlated with average TAG content per cell measured by bulk NMR, with a linear regression yielding a linear fit with r2 = 0.9974. This correlation compares favorably to previous calibrations of flow cytometry protocols to lipid content measured via extraction, and calibration by NMR avoids the time and complexity that is generally required for lipid quantitation via extraction. Flow cytometry calibrated to a direct measurement of TAG content can be used to investigate the distribution of lipid contents for cells within a culture. Our flow cytometry measurements showed that Chlorella vulgaris cells subjected to nitrogen limitation exhibited higher mean lipid content but a wider distribution of lipid content that overlapped the relatively narrow distribution of lipid content for replete cells, suggesting that nitrogen limitation induces lipid accumulation in only a subset of cells. Calibration of flow cytometry protocols using direct in situ measurement of TAG content via NMR will facilitate rapid development of more precise flow cytometry protocols, enabling investigation of algal lipid accumulation for development of more productive algal biofuel feedstocks and cultivation protocols.
Bryant, Kirsten L; Baird, Barbara; Holowka, David
2015-02-27
Biosynthetic trafficking of receptors and other membrane-associated proteins from the endoplasmic reticulum (ER) to the plasma membrane (PM) underlies the capacity of these proteins to participate in crucial cellular roles. Phosphoinositides have been shown to mediate distinct biological functions in cells, and phosphatidylinositol 4-phosphate (PI4P), in particular, has emerged as a key regulator of biosynthetic trafficking. To investigate the source of PI4P that orchestrates trafficking events, we developed a novel flow cytometry based method to monitor biosynthetic trafficking of transiently transfected proteins. We demonstrated that our method can be used to assess the trafficking of both type-1 transmembrane and GPI-linked proteins, and that it can accurately monitor the pharmacological disruption of biosynthetic trafficking with brefeldin A, a well-documented inhibitor of early biosynthetic trafficking. Furthermore, utilizing our newly developed method, we applied pharmacological inhibition of different isoforms of PI 4-kinase to reveal a role for a distinct pool of PI4P, synthesized by PI4KIIIα, in ER-to-PM trafficking. Taken together, these findings provide evidence that a specific pool of PI4P plays a role in biosynthetic trafficking of two different classes of proteins from the ER to the Golgi complex. Furthermore, our simple, flow cytometry-based biosynthetic trafficking assay can be widely applied to the study of multiple classes of proteins and varied pharmacological and genetic perturbations.
Isolation and characterization of mouse innate lymphoid cells.
Halim, Timotheus Y F; Takei, Fumio
2014-08-01
Innate lymphoid cells (ILCs) are rare populations of cytokine-producing lymphocytes and are divided into three groups, namely ILC1, ILC2, and ILC3, based on the cytokines that they produce. They comprise less than 1% of lymphocytes in mucosal tissues and express no unique cell surface markers. Therefore, they can only be identified by combinations of multiple cell surface markers and further characterized by cytokine production in vitro. Thus, multicolor flow cytometry is the only reliable method to purify and characterize ILCs. Here we describe the methods for cell preparation, flow cytometric analysis, and purification of murine ILC2 and ILC3. Copyright © 2014 John Wiley & Sons, Inc.
Final Report Nucleic Acid System - Hybrid PCR and Multiplex Assay Project Phase 2
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koopman, R P; Langlois, R G; Nasarabadi, S
2002-04-17
This report covers phase 2 (year 2) of the Nucleic Acid System--Hybrid PCR and Multiplex Assay project. The objective of the project is to reduce to practice the detection and identification of biological warfare pathogens by the nucleic acid recognition technique of PCR (polymerase chain reaction) in a multiplex mode using flow cytometry. The Hybrid instrument consists of a flow-through PCR module capable of handling a multiplexed PCR assay, a hybridizing module capable of hybridizing multiplexed PCR amplicons and beads, and a flow cytometer module for bead-based identification, all controlled by a single computer. Multiplex immunoassay using bead-based Luminex flowmore » cytometry is available, allowing rapid screening for many agents. PCR is highly specific and complements and verifies immunoassay. It can also be multiplexed and detection provided using the bead-based Luminex flow cytometer. This approach allows full access to the speed and 100-fold multiplex capability of flow cytometry for rapid screening as well as the accuracy and specificity of PCR. This project has two principal activities: (1) Design, build and test a prototype hybrid PCR/flow cytometer with the basic capabilities for rapid, broad spectrum detection and identification, and (2) Develop and evaluate multiplex flow analysis assay protocols and reagents for the simultaneous detection of PCR products. This project requires not only building operationally functional instrumentation but also developing the chemical assays for detection of priority pathogens. This involves development and evaluation of multiplex flow analysis assay protocols and reagents for the simultaneous detection of PCR products.« less
2012-01-01
Background Malaria remains a major cause of morbidity and mortality worldwide. Flow cytometry-based assays that take advantage of fluorescent protein (FP)-expressing malaria parasites have proven to be valuable tools for quantification and sorting of specific subpopulations of parasite-infected red blood cells. However, identification of rare subpopulations of parasites using green fluorescent protein (GFP) labelling is complicated by autofluorescence (AF) of red blood cells and low signal from transgenic parasites. It has been suggested that cell sorting yield could be improved by using filters that precisely match the emission spectrum of GFP. Methods Detection of transgenic Plasmodium falciparum parasites expressing either tdTomato or GFP was performed using a flow cytometer with interchangeable optical filters. Parasitaemia was evaluated using different optical filters and, after optimization of optics, the GFP-expressing parasites were sorted and analysed by microscopy after cytospin preparation and by imaging cytometry. Results A new approach to evaluate filter performance in flow cytometry using two-dimensional dot blot was developed. By selecting optical filters with narrow bandpass (BP) and maximum position of filter emission close to GFP maximum emission in the FL1 channel (510/20, 512/20 and 517/20; dichroics 502LP and 466LP), AF was markedly decreased and signal-background improve dramatically. Sorting of GFP-expressing parasite populations in infected red blood cells at 90 or 95% purity with these filters resulted in 50-150% increased yield when compared to the standard filter set-up. The purity of the sorted population was confirmed using imaging cytometry and microscopy of cytospin preparations of sorted red blood cells infected with transgenic malaria parasites. Discussion Filter optimization is particularly important for applications where the FP signal and percentage of positive events are relatively low, such as analysis of parasite-infected samples with in the intention of gene-expression profiling and analysis. The approach outlined here results in substantially improved yield of GFP-expressing parasites, and requires decreased sorting time in comparison to standard methods. It is anticipated that this protocol will be useful for a wide range of applications involving rare events. PMID:22950515
Predictions of CD4 lymphocytes’ count in HIV patients from complete blood count
2013-01-01
Background HIV diagnosis, prognostic and treatment requires T CD4 lymphocytes’ number from flow cytometry, an expensive technique often not available to people in developing countries. The aim of this work is to apply a previous developed methodology that predicts T CD4 lymphocytes’ value based on total white blood cell (WBC) count and lymphocytes count applying sets theory, from information taken from the Complete Blood Count (CBC). Methods Sets theory was used to classify into groups named A, B, C and D the number of leucocytes/mm3, lymphocytes/mm3, and CD4/μL3 subpopulation per flow cytometry of 800 HIV diagnosed patients. Union between sets A and C, and B and D were assessed, and intersection between both unions was described in order to establish the belonging percentage to these sets. Results were classified into eight ranges taken by 1000 leucocytes/mm3, calculating the belonging percentage of each range with respect to the whole sample. Results Intersection (A ∪ C) ∩ (B ∪ D) showed an effectiveness in the prediction of 81.44% for the range between 4000 and 4999 leukocytes, 91.89% for the range between 3000 and 3999, and 100% for the range below 3000. Conclusions Usefulness and clinical applicability of a methodology based on sets theory were confirmed to predict the T CD4 lymphocytes’ value, beginning with WBC and lymphocytes’ count from CBC. This methodology is new, objective, and has lower costs than the flow cytometry which is currently considered as Gold Standard. PMID:24034560
Wiklander, Oscar P. B.; Bostancioglu, R. Beklem; Welsh, Joshua A.; Zickler, Antje M.; Murke, Florian; Corso, Giulia; Felldin, Ulrika; Hagey, Daniel W.; Evertsson, Björn; Liang, Xiu-Ming; Gustafsson, Manuela O.; Mohammad, Dara K.; Wiek, Constanze; Hanenberg, Helmut; Bremer, Michel; Gupta, Dhanu; Björnstedt, Mikael; Giebel, Bernd; Nordin, Joel Z.; Jones, Jennifer C.; EL Andaloussi, Samir; Görgens, André
2018-01-01
Extracellular vesicles (EVs) can be harvested from cell culture supernatants and from all body fluids. EVs can be conceptually classified based on their size and biogenesis as exosomes and microvesicles. Nowadays, it is however commonly accepted in the field that there is a much higher degree of heterogeneity within these two subgroups than previously thought. For instance, the surface marker profile of EVs is likely dependent on the cell source, the cell’s activation status, and multiple other parameters. Within recent years, several new methods and assays to study EV heterogeneity in terms of surface markers have been described; most of them are being based on flow cytometry. Unfortunately, such methods generally require dedicated instrumentation, are time-consuming and demand extensive operator expertise for sample preparation, acquisition, and data analysis. In this study, we have systematically evaluated and explored the use of a multiplex bead-based flow cytometric assay which is compatible with most standard flow cytometers and facilitates a robust semi-quantitative detection of 37 different potential EV surface markers in one sample simultaneously. First, assay variability, sample stability over time, and dynamic range were assessed together with the limitations of this assay in terms of EV input quantity required for detection of differently abundant surface markers. Next, the potential effects of EV origin, sample preparation, and quality of the EV sample on the assay were evaluated. The findings indicate that this multiplex bead-based assay is generally suitable to detect, quantify, and compare EV surface signatures in various sample types, including unprocessed cell culture supernatants, cell culture-derived EVs isolated by different methods, and biological fluids. Furthermore, the use and limitations of this assay to assess heterogeneities in EV surface signatures was explored by combining different sets of detection antibodies in EV samples derived from different cell lines and subsets of rare cells. Taken together, this validated multiplex bead-based flow cytometric assay allows robust, sensitive, and reproducible detection of EV surface marker expression in various sample types in a semi-quantitative way and will be highly valuable for many researchers in the EV field in different experimental contexts.
Wiklander, Oscar P B; Bostancioglu, R Beklem; Welsh, Joshua A; Zickler, Antje M; Murke, Florian; Corso, Giulia; Felldin, Ulrika; Hagey, Daniel W; Evertsson, Björn; Liang, Xiu-Ming; Gustafsson, Manuela O; Mohammad, Dara K; Wiek, Constanze; Hanenberg, Helmut; Bremer, Michel; Gupta, Dhanu; Björnstedt, Mikael; Giebel, Bernd; Nordin, Joel Z; Jones, Jennifer C; El Andaloussi, Samir; Görgens, André
2018-01-01
Extracellular vesicles (EVs) can be harvested from cell culture supernatants and from all body fluids. EVs can be conceptually classified based on their size and biogenesis as exosomes and microvesicles. Nowadays, it is however commonly accepted in the field that there is a much higher degree of heterogeneity within these two subgroups than previously thought. For instance, the surface marker profile of EVs is likely dependent on the cell source, the cell's activation status, and multiple other parameters. Within recent years, several new methods and assays to study EV heterogeneity in terms of surface markers have been described; most of them are being based on flow cytometry. Unfortunately, such methods generally require dedicated instrumentation, are time-consuming and demand extensive operator expertise for sample preparation, acquisition, and data analysis. In this study, we have systematically evaluated and explored the use of a multiplex bead-based flow cytometric assay which is compatible with most standard flow cytometers and facilitates a robust semi-quantitative detection of 37 different potential EV surface markers in one sample simultaneously. First, assay variability, sample stability over time, and dynamic range were assessed together with the limitations of this assay in terms of EV input quantity required for detection of differently abundant surface markers. Next, the potential effects of EV origin, sample preparation, and quality of the EV sample on the assay were evaluated. The findings indicate that this multiplex bead-based assay is generally suitable to detect, quantify, and compare EV surface signatures in various sample types, including unprocessed cell culture supernatants, cell culture-derived EVs isolated by different methods, and biological fluids. Furthermore, the use and limitations of this assay to assess heterogeneities in EV surface signatures was explored by combining different sets of detection antibodies in EV samples derived from different cell lines and subsets of rare cells. Taken together, this validated multiplex bead-based flow cytometric assay allows robust, sensitive, and reproducible detection of EV surface marker expression in various sample types in a semi-quantitative way and will be highly valuable for many researchers in the EV field in different experimental contexts.
NASA Astrophysics Data System (ADS)
Retnakumari, Archana; Jayasimhan, Jasusri; Chandran, Parwathy; Menon, Deepthy; Nair, Shantikumar; Mony, Ullas; Koyakutty, Manzoor
2011-07-01
Protein stabilized gold nanoclusters (Au-NCs) are biocompatible, near-infrared (NIR) emitting nanosystems having a wide range of biomedical applications. Here, we report the development of a Au-NC based targeted fluorescent nano-bioprobe for the flow-cytometric detection of acute myeloid leukaemia (AML) cells. Au-NCs with ~ 25-28 atoms showing bright red-NIR fluorescence (600-750 nm) and average size of ~ 0.8 nm were prepared by bovine serum albumin assisted reduction-cum-stabilization in aqueous phase. The protein protected clusters were conjugated with monoclonal antibody against CD33 myeloid antigen, which is overexpressed in ~ 99.2% of the primitive population of AML cells, as confirmed by immunophenotyping using flow cytometry. Au-NC-CD33 conjugates having average size of ~ 12 nm retained bright fluorescence over an extended duration of ~ a year, as the albumin protein protects Au-NCs against degradation. Nanotoxicity studies revealed excellent biocompatibility of Au-NC conjugates, as they showed no adverse effect on the cell viability and inflammatory response. Target specificity of the conjugates for detecting CD33 expressing AML cells (KG1a) in flow cytometry showed specific staining of ~ 95.4% of leukaemia cells within 1-2 h compared to a non-specific uptake of ~ 8.2% in human peripheral blood cells (PBMCs) which are CD33low. The confocal imaging also demonstrated the targeted uptake of CD33 conjugated Au-NCs by leukaemia cells, thus confirming the flow cytometry results. This study demonstrates that novel nano-bioprobes can be developed using protein protected fluorescent nanoclusters of Au for the molecular receptor targeted flow cytometry based detection and imaging of cancer cells.
Opto-fluidics based microscopy and flow cytometry on a cell phone for blood analysis.
Zhu, Hongying; Ozcan, Aydogan
2015-01-01
Blood analysis is one of the most important clinical tests for medical diagnosis. Flow cytometry and optical microscopy are widely used techniques to perform blood analysis and therefore cost-effective translation of these technologies to resource limited settings is critical for various global health as well as telemedicine applications. In this chapter, we review our recent progress on the integration of imaging flow cytometry and fluorescent microscopy on a cell phone using compact, light-weight and cost-effective opto-fluidic attachments integrated onto the camera module of a smartphone. In our cell-phone based opto-fluidic imaging cytometry design, fluorescently labeled cells are delivered into the imaging area using a disposable micro-fluidic chip that is positioned above the existing camera unit of the cell phone. Battery powered light-emitting diodes (LEDs) are butt-coupled to the sides of this micro-fluidic chip without any lenses, which effectively acts as a multimode slab waveguide, where the excitation light is guided to excite the fluorescent targets within the micro-fluidic chip. Since the excitation light propagates perpendicular to the detection path, an inexpensive plastic absorption filter is able to reject most of the scattered light and create a decent dark-field background for fluorescent imaging. With this excitation geometry, the cell-phone camera can record fluorescent movies of the particles/cells as they are flowing through the microchannel. The digital frames of these fluorescent movies are then rapidly processed to quantify the count and the density of the labeled particles/cells within the solution under test. With a similar opto-fluidic design, we have recently demonstrated imaging and automated counting of stationary blood cells (e.g., labeled white blood cells or unlabeled red blood cells) loaded within a disposable cell counting chamber. We tested the performance of this cell-phone based imaging cytometry and blood analysis platform by measuring the density of red and white blood cells as well as hemoglobin concentration in human blood samples, which showed a good match to our measurement results obtained using a commercially available hematology analyzer. Such a cell-phone enabled opto-fluidics microscopy, flow cytometry, and blood analysis platform could be especially useful for various telemedicine applications in remote and resource-limited settings.
Keserue, Hans-Anton; Baumgartner, Andreas; Felleisen, Richard; Egli, Thomas
2012-11-01
We developed a rapid detection method for Legionella pneumophila (Lp) by filtration, immunomagnetic separation, double fluorescent staining, and flow cytometry (IMS-FCM method). The method requires 120 min and can discriminate 'viable' and 'membrane-damaged' cells. The recovery is over 85% of spiked Lp SG 1 cells in 1 l of tap water and detection limits are around 50 and 15 cells per litre for total and viable Lp, respectively. The method was compared using water samples from house installations in a blind study with three environmental laboratories performing the ISO 11731 plating method. In 53% of the water samples from different taps and showers significantly higher concentrations of Lp were detected by flow cytometry. No correlation to the plate culture method was found. Since also 'viable but not culturable' (VNBC) cells are detected by our method, this result was expected. The IMS-FCM method is limited by the specificity of the used antibodies; in the presented case they target Lp serogroups 1-12. This and the fact that no Lp-containing amoebae are detected may explain why in 21% of all samples higher counts were observed using the plate culture method. Though the IMS-FCM method is not yet fit to completely displace the established plating method (ISO 11731) for routine Lp monitoring, it has major advantages to plating and can quickly provide important insights into the ecology of this pathogen in water distribution systems. © 2012 The Authors. Microbial Biotechnology © 2012 Society for Applied Microbiology and Blackwell Publishing Ltd.
miRNA detection at single-cell resolution using microfluidic LNA flow-FISH
Wu, Meiye; Piccini, Matthew Ernest; Koh, Chung -Yan; ...
2014-08-20
Flow cytometry in combination with fluorescent in situ hybridization (flow-FISH) is a powerful technique that can be utilized to rapidly detect nucleic acids at single-cell resolution without the need for homogenization or nucleic acid extraction. Here, we describe a microfluidic-based method which enables the detection of microRNAs or miRNAs in single intact cells by flow-FISH using locked nucleic acid (LNA)-containing probes. Our method can be applied to all RNA species including mRNA and small noncoding RNA and is suitable for multiplexing with protein immunostaining in the same cell. For demonstration of our method, this chapter details the detection of miR155more » and CD69 protein in PMA and ionomycin-stimulated Jurkat cells. Here, we also include instructions on how to set up a microfluidic chip sample preparation station to prepare cells for imaging and analysis on a commercial flow cytometer or a custom-built micro-flow cytometer.« less
Wide-field Fluorescent Microscopy and Fluorescent Imaging Flow Cytometry on a Cell-phone
Zhu, Hongying; Ozcan, Aydogan
2013-01-01
Fluorescent microscopy and flow cytometry are widely used tools in biomedical research and clinical diagnosis. However these devices are in general relatively bulky and costly, making them less effective in the resource limited settings. To potentially address these limitations, we have recently demonstrated the integration of wide-field fluorescent microscopy and imaging flow cytometry tools on cell-phones using compact, light-weight, and cost-effective opto-fluidic attachments. In our flow cytometry design, fluorescently labeled cells are flushed through a microfluidic channel that is positioned above the existing cell-phone camera unit. Battery powered light-emitting diodes (LEDs) are butt-coupled to the side of this microfluidic chip, which effectively acts as a multi-mode slab waveguide, where the excitation light is guided to uniformly excite the fluorescent targets. The cell-phone camera records a time lapse movie of the fluorescent cells flowing through the microfluidic channel, where the digital frames of this movie are processed to count the number of the labeled cells within the target solution of interest. Using a similar opto-fluidic design, we can also image these fluorescently labeled cells in static mode by e.g. sandwiching the fluorescent particles between two glass slides and capturing their fluorescent images using the cell-phone camera, which can achieve a spatial resolution of e.g. ~ 10 μm over a very large field-of-view of ~ 81 mm2. This cell-phone based fluorescent imaging flow cytometry and microscopy platform might be useful especially in resource limited settings, for e.g. counting of CD4+ T cells toward monitoring of HIV+ patients or for detection of water-borne parasites in drinking water. PMID:23603893
Wide-field fluorescent microscopy and fluorescent imaging flow cytometry on a cell-phone.
Zhu, Hongying; Ozcan, Aydogan
2013-04-11
Fluorescent microscopy and flow cytometry are widely used tools in biomedical research and clinical diagnosis. However these devices are in general relatively bulky and costly, making them less effective in the resource limited settings. To potentially address these limitations, we have recently demonstrated the integration of wide-field fluorescent microscopy and imaging flow cytometry tools on cell-phones using compact, light-weight, and cost-effective opto-fluidic attachments. In our flow cytometry design, fluorescently labeled cells are flushed through a microfluidic channel that is positioned above the existing cell-phone camera unit. Battery powered light-emitting diodes (LEDs) are butt-coupled to the side of this microfluidic chip, which effectively acts as a multi-mode slab waveguide, where the excitation light is guided to uniformly excite the fluorescent targets. The cell-phone camera records a time lapse movie of the fluorescent cells flowing through the microfluidic channel, where the digital frames of this movie are processed to count the number of the labeled cells within the target solution of interest. Using a similar opto-fluidic design, we can also image these fluorescently labeled cells in static mode by e.g. sandwiching the fluorescent particles between two glass slides and capturing their fluorescent images using the cell-phone camera, which can achieve a spatial resolution of e.g. - 10 μm over a very large field-of-view of - 81 mm(2). This cell-phone based fluorescent imaging flow cytometry and microscopy platform might be useful especially in resource limited settings, for e.g. counting of CD4+ T cells toward monitoring of HIV+ patients or for detection of water-borne parasites in drinking water.
Kabani, Sarah; Waterfall, Martin; Matthews, Keith R
2010-01-01
Studies on the cell-cycle of Trypanosoma brucei have revealed several unusual characteristics that differ from the model eukaryotic organisms. However, the inability to isolate homogenous populations of parasites in distinct cell-cycle stages has limited the analysis of trypanosome cell division and complicated the understanding of mutant phenotypes with possible impact on cell-cycle related events. Although hydroxyurea-induced cell-cycle arrest in procyclic and bloodstream forms has been applied recently with success, such block-release protocols can complicate the analysis of cell-cycle regulated events and have the potential to disrupt important cell-cycle checkpoints. An alternative approach based on flow cytometry of parasites stained with Vybrant DyeCycle Orange circumvents this problem, but is restricted to procyclic form parasites. Here, we apply Vybrant Dyecycle Violet staining coupled with flow cytometry to effectively select different cell-cycle stages of bloodstream form trypanosomes. Moreover, the sorted parasites remain viable, although synchrony is rapidly lost. This method enables cell-cycle enrichment of populations of trypanosomes in their mammal infective stage, particularly at the G1 phase.
Kabani, Sarah; Waterfall, Martin; Matthews, Keith R.
2010-01-01
Studies on the cell-cycle of Trypanosoma brucei have revealed several unusual characteristics that differ from the model eukaryotic organisms. However, the inability to isolate homogenous populations of parasites in distinct cell-cycle stages has limited the analysis of trypanosome cell division and complicated the understanding of mutant phenotypes with possible impact on cell-cycle related events. Although hydroxyurea-induced cell-cycle arrest in procyclic and bloodstream forms has been applied recently with success, such block-release protocols can complicate the analysis of cell-cycle regulated events and have the potential to disrupt important cell-cycle checkpoints. An alternative approach based on flow cytometry of parasites stained with Vybrant DyeCycle Orange circumvents this problem, but is restricted to procyclic form parasites. Here, we apply Vybrant Dyecycle Violet staining coupled with flow cytometry to effectively select different cell-cycle stages of bloodstream form trypanosomes. Moreover, the sorted parasites remain viable, although synchrony is rapidly lost. This method enables cell-cycle enrichment of populations of trypanosomes in their mammal infective stage, particularly at the G1 phase. PMID:19729042
Imaging flow cytometry for phytoplankton analysis.
Dashkova, Veronika; Malashenkov, Dmitry; Poulton, Nicole; Vorobjev, Ivan; Barteneva, Natasha S
2017-01-01
This review highlights the concepts and instrumentation of imaging flow cytometry technology and in particular its use for phytoplankton analysis. Imaging flow cytometry, a hybrid technology combining speed and statistical capabilities of flow cytometry with imaging features of microscopy, is rapidly advancing as a cell imaging platform that overcomes many of the limitations of current techniques and contributed significantly to the advancement of phytoplankton analysis in recent years. This review presents the various instrumentation relevant to the field and currently used for assessment of complex phytoplankton communities' composition and abundance, size structure determination, biovolume estimation, detection of harmful algal bloom species, evaluation of viability and metabolic activity and other applications. Also we present our data on viability and metabolic assessment of Aphanizomenon sp. cyanobacteria using Imagestream X Mark II imaging cytometer. Herein, we highlight the immense potential of imaging flow cytometry for microalgal research, but also discuss limitations and future developments. Copyright © 2016 Elsevier Inc. All rights reserved.
Mlika, Mona; Kasmi, Rihem; Safra, Ines; Braham, Emna; Chebbi, Chokri; Mezni, Faouzi El
2017-10-01
Diffuse interstitial pneumonias are considered as a group of multiple affections characterized by challenging diagnoses because of the lack of specific clinical signs. Radiologic investigations highlight the diagnoses in most of the cases but bronchoalveolar lavage plays a key role in the diagnostic diagram. We aim to compare the immunocytochemical technique and the flow cytometry in the phenotyping of lymphocytic alveolitis. We described a series of 32 lymphocytic alveolitis, which were analyzed using immunocytochemistry and flow cytometry. We found a good reproducibility between the immunocytochemistry performed on smears and cytoblocks (kappa=0.7) and a poor reproducibility between immunocytochemistry and flow cytometry (kappa=0.35). Our study emphasized on the poor reproducibility between immunocytochemistry and flow cytometry. Further studies about the reliability of both techniques are needed especially in discordant cases. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Multinode acoustic focusing for parallel flow cytometry
Piyasena, Menake E.; Suthanthiraraj, Pearlson P. Austin; Applegate, Robert W.; Goumas, Andrew M.; Woods, Travis A.; López, Gabriel P.; Graves, Steven W.
2012-01-01
Flow cytometry can simultaneously measure and analyze multiple properties of single cells or particles with high sensitivity and precision. Yet, conventional flow cytometers have fundamental limitations with regards to analyzing particles larger than about 70 microns, analyzing at flow rates greater than a few hundred microliters per minute, and providing analysis rates greater than 50,000 per second. To overcome these limits, we have developed multi-node acoustic focusing flow cells that can position particles (as small as a red blood cell and as large as 107 microns in diameter) into as many as 37 parallel flow streams. We demonstrate the potential of such flow cells for the development of high throughput, parallel flow cytometers by precision focusing of flow cytometry alignment microspheres, red blood cells, and the analysis of CD4+ cellular immunophenotyping assay. This approach will have significant impact towards the creation of high throughput flow cytometers for rare cell detection applications (e.g. circulating tumor cells), applications requiring large particle analysis, and high volume flow cytometry. PMID:22239072
Accurate live and dead bacterial cell enumeration using flow cytometry (Conference Presentation)
NASA Astrophysics Data System (ADS)
Ou, Fang; McGoverin, Cushla; Swift, Simon; Vanholsbeeck, Frédérique
2017-03-01
Flow cytometry (FCM) is based on the detection of scattered light and fluorescence to identify cells with particular characteristics of interest. However most FCM cannot precisely control the flow through its interrogation point and hence the volume and concentration of the sample cannot be immediately obtained. The easiest, most reliable and inexpensive way of obtaining absolute counts with FCM is by using reference beads. We investigated a method of using FCM with reference beads to measure live and dead bacterial concentration over the range of 106 to 108 cells/mL and ratio varying from 0 to 100%. We believe we are the first to use this method for such a large cell concentration range while also establishing the effect of varying the live/dead bacteria ratios. Escherichia coli solutions with differing ratios of live:dead cells were stained with fluorescent dyes SYTO 9 and propidium iodide (PI), which label live and dead cells, respectively. Samples were measured using a LSR II Flow Cytometer (BD Biosciences); using 488 nm excitation with 20 mW power. Both SYTO 9 and PI fluorescence were collected and threshold was set to side scatter. Traditional culture-based plate count was done in parallel to the FCM analysis. The concentration of live bacteria from FCM was compared to that obtained by plate counts. Preliminary results show that the concentration of live bacteria obtained by FCM and plate counts correlate well with each other and indicates this may be extended to a wider concentration range or for studying other cell characteristics.
Darzynkiewicz, Zbigniew; Traganos, Frank; Zhao, Hong; Halicka, H. Dorota; Li, Jiangwei
2011-01-01
This review covers progress in the development of cytometric methodologies designed to assess DNA replication and RNA synthesis. The early approaches utilizing autoradiography to detect incorporation of 3H- or 14C-labeled thymidine were able to identify the four fundamental phases of the cell cycle G1, S, G2, and M, and by analysis of the fraction of labeled mitosis (FLM), to precisely define the kinetics of cell progression through these phases. Analysis of 3H-uridine incorporation and RNA content provided the means to distinguish quiescent G0 from cycling G1 cells. Subsequent progress in analysis of DNA replication was based on the use of BrdU as a DNA precursor and its detection by the quenching of the fluorescence intensity of DNA-bound fluorochromes such as Hoechst 33358 or acridine orange as measured by flow cytometry. Several variants of this methodology have been designed and used in studies to detect anticancer drug-induced perturbations of cell cycle kinetics. The next phase of method development, which was particularly useful in studies of the cell cycle in vivo, including clinical applications, relied on immunocytochemical detection of incorporated halogenated DNA or RNA precursors. This approach however was hampered by the need for DNA denaturation, which made it difficult to concurrently detect other cell constituents for multiparametric analysis. The recently introduced “click chemistry” approach has no such limitation and is the method of choice for analysis of DNA replication and RNA synthesis. This method is based on the use of 5-ethynyl-2′deoxyuridine (EdU) as a DNA precursor or 5-ethynyluridine (EU) as an RNA precursor and their detection with fluorochrome-tagged azides utilizing a copper (I) catalyzed [3+2] cycloaddition. Several examples are presented that illustrate incorporation of EdU or EU in cells subjected to DNA damage detected as histone H2AX phosphorylation that have been analyzed by flow or laser scanning cytometry. PMID:21425239
ZAP-70 staining in chronic lymphocytic leukemia.
Villamor, Neus
2005-05-01
Chronic lymphocytic leukemia (CLL) is the most common chronic leukemia in Western countries. The disease has an extremely variable clinical course, and several prognostic features have been identified to assess individual risk. The configuration of the immunoglobulin variable heavy-chain gene (IgV(H)) is a strong predictor of the outcome. CLL patients with unmutated IgV(H) status have an aggressive clinical course and a short survival. Unfortunately, analysis of IgV(H) gene configuration is not available in most clinical laboratories. A small number of genes are differentially expressed between unmutated IgV(H) and mutated IgV(H) clinical forms of CLL. One of these genes is ZAP-70, which is detected in leukemic cells from patients with the unmutated IgV(H) form of CLL. Flow cytometry presents advantages over other methods to detect ZAP-70, and its quantification by flow cytometry has proved its predictive value. This unit focuses on protocols to quantify ZAP-70 by flow cytometry in CLL.
Recombinant scFv antibodies against infectious pancreatic necrosis virus isolated by flow cytometry.
Xu, Li-Ming; Zhao, Jing-Zhuang; Liu, Miao; Cao, Yong-Sheng; Yin, Jia-Sheng; Liu, Hong-Bai; Lu, Tongyan
2016-11-01
Infectious pancreatic necrosis is a significant disease of farmed salmonids in China. In this study, a single chain variable fragment (scFv) antibody library derived from rainbow trout (Oncorhynchus mykiss) and viral protein VP2 of a Chinese infectious pancreatic necrosis virus (IPNV) isolate ChRtm213 were co-expressed by a bacterial display technology. The library was subjected to three rounds of screening by flow cytometry (FCM) to select IPNV specific antibodies. Six antibody clones with different mean fluorescence intensities (MFI) were obtained by picking colonies at random. The antibody clones were expressed and purified. The purified IPNV-specific scFv antibodies were used successfully in Western blotting, enzyme linked immunosorbent assay (ELISA) and an immunofluorescence antibody test (IFAT). This method provides a high throughput means to screen an antibody library by flow cytometry, and isolate a panel of antibody that can be used as potential reagents for the detection and study of IPNV that are prevalent in China. Copyright © 2016 Elsevier B.V. All rights reserved.
Lee, Yong Sun; Yi, Jung-Sun; Seo, Souk Jin; Kim, Joo Hwan; Jung, Mi-Sook; Seo, Im-Kwon; Ahn, Ilyoung; Ko, Kyungyuk; Kim, Tae Sung; Lim, Kyung Min; Sohn, Soojung
2017-02-01
The local lymph node assay using 5-bromo-2-deoxyuridine (BrdU) with flow cytometry (LLNA: BrdU-FCM) is a modified LLNA that is used to identify skin sensitizers by counting BrdU-incorporated lymph node cells (LNCs) with flow cytometry. Unlike other LLNA methods (OECD TG 429, 442A and 442B) in which the CBA/J mouse strain is used, LLNA: BrdU-FCM was originally designed to be compatible with BALB/c, a mouse strain that is more widely used in many countries. To justify the substitution of CBA/J for BALB/c, the equivalence of the test results between two strains shall be established prior to the official implementation of LLNA: BrdU-FCM. This study aims to compare the test results of LLNA: BrdU-FCM produced in BALB/c mice with those in CBA/J mice for 18 reference substances, including 13 sensitizers and 5 non-sensitizers, listed in OECD Test Guideline 429. Based on the LLNA: BrdU-FCM test procedure, we selected an appropriate solvent and then performed preliminary tests to determine the non-irritating dose ranges for the main study, which revealed the difference in the irritation responses to 8 of the 18 chemicals between the two strains. In the main study, we measured the changes in the number of total LNCs, which indicated differences in the responses to test chemicals between the two strains. However, the stimulation index obtained with the counts of BrdU-incorporated LNCs with 7-AAD using flow cytometry yielded comparable results and 100% concordance between the BALB/c and CBA/J mouse strains was achieved, suggesting that the performance of LLNA: BrdU-FCM using BALB/c mice was equivalent to that with CBA/J mice. Copyright © 2016 Elsevier Inc. All rights reserved.
Physiological changes induced in bacteria following pH stress as a model for space research
NASA Astrophysics Data System (ADS)
Baatout, Sarah; Leys, Natalie; Hendrickx, Larissa; Dams, Annik; Mergeay, Max
2007-02-01
The physiology of the environmental bacterium Cupriavidus metallidurans CH34 (previously Ralstonia metallidurans) is being studied in comparison to the clinical model bacterium Escherichia coli in order to understand its behaviour and resistance under extreme conditions (pH, temperature, etc.). This knowledge is of importance in the light of the potential use and interest of this strain for space biology and bioremediation. Flow cytometry provides powerful means to measure a wide range of cell characteristics in microbiological research. In order to estimate physiological changes associated with pH stress, flow cytometry was employed to estimate the extent of damage on cell size, membrane integrity and potential, and production of superoxides in the two bacterial strains. Suspensions of C. metallidurans and E. coli were submitted to a 1-h pH stress (2 to 12). For flow cytometry, fluorochromes, including propidium iodide, 3, 3'-dihexyloxacarbocyanine iodide and hydroethidine were chosen as analytical parameters for identifying the physiological state and the overall fitness of individual cells. A physiologic state of the bacterial population was assessed with a Coulter EPICS XL analyser based on the differential uptakes of these fluorescent stains. C. metallidurans cells exhibited a different staining intensity than E. coli cells. For both bacterial strains, the physiological status was only slightly affected between pH 6 and 8 in comparison with pH 7 which represents the reference pH. Moderate physiological damage could be observed at pH 4 and 5 as well as at pH 9 in both strains. At pH 2, 10 and 12, membrane permeability and potential and superoxide anion production were increased to high levels showing dramatic physiological changes. It is apparent that a range of significant physiological alterations occurs after pH stress. Fluorescent staining methods coupled with flow cytometry are useful and complementary for monitoring physiological changes induced not only by pH stress but also temperature and oxidative stress, radiation, pressure as well as space stress.
New drugs and methods of doping and manipulation.
Thevis, Mario; Kohler, Maxie; Schänzer, Wilhelm
2008-01-01
The issue of doping in sport is multifaceted. New drugs not only with anabolic properties such as selective androgen receptor modulators, synthetic insulins, blood doping with erythropoietins or homologous and autologous blood transfusions but also with sample manipulation have necessitated sensitive, comprehensive and specific detection assays allowing for the identification of cheats. New methods based on mass spectrometry, flow cytometry and immunological techniques have been introduced and improved in the past years to support and enhance the antidoping fight. Although numerous approaches are successful and promising, these methods still have some shortcomings.
Supercontinuum white light lasers for flow cytometry
Telford, William G.; Subach, Fedor V.; Verkhusha, Vladislav V.
2009-01-01
Excitation of fluorescent probes for flow cytometry has traditionally been limited to a few discrete laser lines, an inherent limitation in our ability to excite the vast array of fluorescent probes available for cellular analysis. In this report, we have used a supercontinuum (SC) white light laser as an excitation source for flow cytometry. By selectively filtering the wavelength of interest, almost any laser wavelength in the visible spectrum can be separated and used for flow cytometric analysis. The white light lasers used in this study were integrated into a commercial flow cytometry platform, and a series of high-transmission bandpass filters used to select wavelength ranges from the blue (~480 nm) to the long red (>700 nm). Cells labeled with a variety of fluorescent probes or expressing fluorescent proteins were then analyzed, in comparison with traditional lasers emitting at wavelengths similar to the filtered SC source. Based on a standard sensitivity metric, the white light laser bandwidths produced similar excitation levels to traditional lasers for a wide variety of fluorescent probes and expressible proteins. Sensitivity assessment using fluorescent bead arrays confirmed that the SC laser and traditional sources resulted in similar levels of detection sensitivity. Supercontinuum white light laser sources therefore have the potential to remove a significant barrier in flow cytometric analysis, namely the limitation of excitation wavelengths. Almost any visible wavelength range can be made available for excitation, allowing access to virtually any fluorescent probe, and permitting “fine-tuning” of excitation wavelength to particular probes. PMID:19072836
Biomarkers of Selenium Chemoprevention of Prostate Cancer
2005-01-01
than Se-Met in inhibiting Flow Kit from BD Pharmigen (San Diego, CA). Stained cells were then quantified by flow cytometry , and the data were analyzed...decrease in Quantitation of Apoptosis by Flow Cytometry . PC-3 cells were plated at cell number accumulation by MSA was related to cell cycle arrest, we... flow exposed to either 5 or 10Mm MSA for 48 or 72 h. Adherent cells harvested by mild cytometry of ethanol-permeabilized cells stained with Pl. Synchro
Schuler, Patrick J.; Harasymczuk, Malgorzata; Schilling, Bastian; Lang, Stephan; Whiteside, Theresa L.
2011-01-01
Objective The ectonucleotidase CD39 is an enzyme involved in adenosine production. Its surface expression on human regulatory T cells (Treg) allows for their flow-cytometry-based isolation from peripheral blood. To further develop and improve this method on a scale supporting translational studies, we introduced capture of CD39+ Treg on magnetic immunobeads. Methods Peripheral blood mononuclear cells (PBMC) obtained from healthy donors were used for negative selection of CD4+ T cells on AutoMACS using antibodies (Abs) specific for all lineage+ cells. CD4+CD39+ Treg were captured by biotin-conjugated anti-CD39 Abs and anti-biotin Ab-coated magnetic beads. Isolated CD4+CD39+ T cells were phenotyped by flow cytometry for Treg-associated markers: CD39, CD73, FOXP3, CD25, CTLA-4, CCR4, CD45RO and CD121a or for the absence of CD127 and CD49d. CFSE-based proliferation assays and ATP hydrolysis were used to measure Treg functions. Results The purity, recovery and viability of the separated CD4+CD39+ T cells were satisfactory. The isolated CD4+CD39+ T cell population consisted of FOXP3+CD25+ T cells which hydrolyzed exogenous ATP and suppressed autologous CD4+ T cell proliferation and of FOXP3negCD25neg T cells without suppressor function. The same two subsets were detectable by flow cytometry in normal PBMC, gating on CD4+CD39+, CD4+CD127neg, CD4+CD49dneg or CD4+CD25high Treg. Conclusion CD4+CD39+ Treg capture on immunobeads led to a discovery of two CD39+ subsets. Similar to CD39+ Treg in the peripheral blood, half of these cells are CD25+FOXP3+ active suppressor cells, while the other half are CD25negFOXP3neg and do not mediate suppression. PMID:21513715
Godin, Jessica; Chen, Chun-Hao; Cho, Sung Hwan; Qiao, Wen; Tsai, Frank; Lo, Yu-Hwa
2008-10-01
Microfluidics and photonics come together to form a field commonly referred to as 'optofluidics'. Flow cytometry provides the field with a technology base from which both microfluidic and photonic components be developed and integrated into a useful device. This article reviews some of the more recent developments to familiarize a reader with the current state of the technologies and also highlights the requirements of the device and how researchers are working to meet these needs.
A Noninvasive and Real-Time Method for Circulating Tumor Cell Detection by In Vivo Flow Cytometry.
Wei, Xunbin; Zhou, Jian; Zhu, Xi; Yang, Xinrong; Yang, Ping; Wang, Qiyan
2017-01-01
The quantification of circulating tumor cells (CTCs) has been considered a potentially powerful tool in cancer diagnosis and prognosis, as CTCs have been shown to appear very early in cancer development. Great efforts have been made to develop methods that were less invasive and more sensitive to detect CTCs earlier. There is growing evidence that CTC clusters have greater metastatic potential than single CTCs. Therefore, the detection of CTC clusters is also important. This chapter is aimed to introduce a noninvasive technique for CTCs detection named in vivo flow cytometry (IVFC), which has been demonstrated to be capable of monitoring CTCs dynamics continuously. Furthermore, IVFC could be helpful for CTC cluster enumeration.
Falay, Mesude; Aktas, Server
2016-11-01
The present study aimed to determine circulating Endothelial Progenitor Cell (EPC) counts by multicolor flow cytometry in healthy individuals and diabetic subjects by means of forming an analysis procedure using a combination of monoclonal antibodies (moAbs), which would correctly detect the circulating EPC count. The circulating EPC count was detected in 40 healthy individuals (20 Female, 20 Male; age range: 26 - 50 years) and 30 Diabetes Mellitus (DM) patients (15 Female, 15 Male; age range: 42 - 55) by multicolor flow cytometry (FCM) in a single-tube panel consisting of 5 CD45/CD31/CD34/CD309/ SYTO® and 16 monoclonal antibodies. Circulating EPC count was 11.33 (7.89 - 15.25) cells/µL in the healthy control group and 4.80 (0.70 - 10.85) cells/µL in the DM group. EPC counts were significantly lower in DM cases that developed coronary artery disease (53.3%) as compared to those that did not (p < 0.001). In the present study, we describe a method that identifies circulating EPC counts by multicolor flow cytometry in a single tube and determines the circulating EPC count in healthy individuals. This is the first study conducted on EPC count in Turkish population. We think that the EPC count found in the present study will be a guide for future studies.
Small lasers in flow cytometry.
Telford, William G
2004-01-01
Laser technology has made tremendous advances in recent years, particularly in the area of diode and diode-pumped solid state sources. Flow cytometry has been a direct beneficiary of these advances, as these small, low-maintenance, inexpensive lasers with reasonable power outputs are integrated into flow cytometers. In this chapter we review the contribution and potential of solid-state lasers to flow cytometry, and show several examples of these novel sources integrated into production flow cytometers. Technical details and critical parameters for successful application of these lasers for biomedical analysis are reviewed.
NASA Astrophysics Data System (ADS)
Montón, Helena; Parolo, Claudio; Aranda-Ramos, Antonio; Merkoçi, Arben; Nogués, Carme
2015-02-01
There is a great demand to develop novel techniques that allow useful and complete monitoring of apoptosis, which is a key factor of several diseases and a target for drug development. Here, we present the use of a novel dual electrochemical/optical label for the detection and study of apoptosis. We combined the specificity of Annexin-V for phosphatidylserine, a phospholipid expressed in the outer membrane of apoptotic cells, with the optical and electrochemical properties of quantum dots to create a more efficient label. Using this conjugate we addressed three important issues: (i) we made the labeling of apoptotic cells faster (30 min) and easier; (ii) we fully characterized the samples by common cell biological techniques (confocal laser scanning microscopy, scanning electron microscopy and flow cytometry); and (iii) we developed a fast, cheap and quantitative electrochemical detection method for apoptotic cells with results in full agreement with those obtained by flow cytometry.There is a great demand to develop novel techniques that allow useful and complete monitoring of apoptosis, which is a key factor of several diseases and a target for drug development. Here, we present the use of a novel dual electrochemical/optical label for the detection and study of apoptosis. We combined the specificity of Annexin-V for phosphatidylserine, a phospholipid expressed in the outer membrane of apoptotic cells, with the optical and electrochemical properties of quantum dots to create a more efficient label. Using this conjugate we addressed three important issues: (i) we made the labeling of apoptotic cells faster (30 min) and easier; (ii) we fully characterized the samples by common cell biological techniques (confocal laser scanning microscopy, scanning electron microscopy and flow cytometry); and (iii) we developed a fast, cheap and quantitative electrochemical detection method for apoptotic cells with results in full agreement with those obtained by flow cytometry. Electronic supplementary information (ESI) available: Optical microscopy images of apoptotic induced cell cultures at different times and negative control of flow cytometry. See DOI: 10.1039/c4nr07191c
An Improved Flow Cytometry Method For Precise Quantitation Of Natural-Killer Cell Activity
NASA Technical Reports Server (NTRS)
Crucian, Brian; Nehlsen-Cannarella, Sandra; Sams, Clarence
2006-01-01
The ability to assess NK cell cytotoxicity using flow cytometry has been previously described and can serve as a powerful tool to evaluate effector immune function in the clinical setting. Previous methods used membrane permeable dyes to identify target cells. The use of these dyes requires great care to achieve optimal staining and results in a broad spectral emission that can make multicolor cytometry difficult. Previous methods have also used negative staining (the elimination of target cells) to identify effector cells. This makes a precise quantitation of effector NK cells impossible due to the interfering presence of T and B lymphocytes, and the data highly subjective to the variable levels of NK cells normally found in human peripheral blood. In this study an improved version of the standard flow cytometry assay for NK activity is described that has several advantages of previous methods. Fluorescent antibody staining (CD45FITC) is used to positively identify target cells in place of membranepermeable dyes. Fluorescent antibody staining of target cells is less labor intensive and more easily reproducible than membrane dyes. NK cells (true effector lymphocytes) are also positively identified by fluorescent antibody staining (CD56PE) allowing a simultaneous absolute count assessment of both NK cells and target cells. Dead cells are identified by membrane disruption using the DNA intercalating dye PI. Using this method, an exact NK:target ratio may be determined for each assessment, including quantitation of NK target complexes. Backimmunoscatter gating may be used to track live vs. dead Target cells via scatter properties. If desired, NK activity may then be normalized to standardized ratios for clinical comparisons between patients, making the determination of PBMC counts or NK cell percentages prior to testing unnecessary. This method provides an exact cytometric determination of NK activity that highly reproducible and may be suitable for routine use in the clinical setting.
Balsam, Joshua; Bruck, Hugh Alan; Rasooly, Avraham
2014-09-07
Here we describe a novel low-cost flow cytometer based on a webcam capable of low cell number detection in a large volume which may overcome the limitations of current flow cytometry. Several key elements have been combined to yield both high throughput and high sensitivity. The first element is a commercially available webcam capable of 187 frames per second video capture at a resolution of 320 × 240 pixels. The second element in this design is a 1 W 450 nm laser module for area-excitation, which combined with the webcam allows for rapid interrogation of a flow field. The final element is a 2D flow-cell which overcomes the flow limitation of hydrodynamic focusing and allows for higher sample throughput in a wider flow field. This cell allows for the linear velocity of target cells to be lower than in a conventional "1D" hydrodynamic focusing flow-cells typically used in cytometry at similar volumetric flow rates. It also allows cells to be imaged at the full frame rate of the webcam. Using this webcam-based flow cytometer with wide-field imaging, it was confirmed that the detection of fluorescently tagged 5 μm polystyrene beads in "1D" hydrodynamic focusing flow-cells was not practical for low cell number detection due to streaking from the motion of the beads, which did not occur with the 2D flow-cell design. The sensitivity and throughput of this webcam-based flow cytometer was then investigated using THP-1 human monocytes stained with SYTO-9 florescent dye in the 2D flow-cell. The flow cytometer was found to be capable of detecting fluorescently tagged cells at concentrations as low as 1 cell per mL at flow rates of 500 μL min(-1) in buffer and in blood. The effectiveness of detection was concentration dependent: at 100 cells per mL 84% of the cells were detected compared to microscopy, 10 cells per mL 79% detected and 1 cell per mL 59% of the cells were detected. With the blood samples spiked to 100 cells per mL, the average concentration for all samples was 91.4 cells per mL, with a 95% confidence interval of 86-97 cells per mL. These low cell concentrations and the large volume capabilities of the system may overcome the limitations of current cytometry, and are applicable to rare cell (such as circulating tumor cell) detection The simplicity and low cost of this device suggests that it may have a potential use in developing point-of-care clinical flow cytometry for resource-poor settings associated with global health.
Streak Imaging Flow Cytometer for Rare Cell Analysis.
Balsam, Joshua; Bruck, Hugh Alan; Ossandon, Miguel; Prickril, Ben; Rasooly, Avraham
2017-01-01
There is a need for simple and affordable techniques for cytology for clinical applications, especially for point-of-care (POC) medical diagnostics in resource-poor settings. However, this often requires adapting expensive and complex laboratory-based techniques that often require significant power and are too massive to transport easily. One such technique is flow cytometry, which has great potential for modification due to the simplicity of the principle of optical tracking of cells. However, it is limited in that regard due to the flow focusing technique used to isolate cells for optical detection. This technique inherently reduces the flow rate and is therefore unsuitable for rapid detection of rare cells which require large volume for analysis.To address these limitations, we developed a low-cost, mobile flow cytometer based on streak imaging. In our new configuration we utilize a simple webcam for optical detection over a large area associated with a wide-field flow cell. The new flow cell is capable of larger volume and higher throughput fluorescence detection of rare cells than the flow cells with hydrodynamic focusing used in conventional flow cytometry. The webcam is an inexpensive, commercially available system, and for fluorescence analysis we use a 1 W 450 nm blue laser to excite Syto-9 stained cells with emission at 535 nm. We were able to detect low concentrations of stained cells at high flow rates of 10 mL/min, which is suitable for rapidly analyzing larger specimen volumes to detect rare cells at appropriate concentration levels. The new rapid detection capabilities, combined with the simplicity and low cost of this device, suggest a potential for clinical POC flow cytometry in resource-poor settings associated with global health.
Laboratory Tests of Multiplex Detection of PCR Amplicons Using the Luminex 100 Flow Analyzer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Venkateswaran, K.S.; Nasarabadi, S.; Langlois, R.G.
2000-05-05
Lawrence Livermore National Laboratory (LLNL) demonstrated the power of flow cytometry in detecting the biological agents simulants at JFT III. LLNL pioneered in the development of advanced nucleic acid analyzer (ANM) for portable real time identification. Recent advances in flow cytometry provide a means for multiplexed nucleic acid detection and immunoassay of pathogenic microorganisms. We are presently developing multiplexed immunoassays for the simultaneous detection of different simulants. Our goal is to build an integrated instrument for both nucleic acid analysis and immuno detection. In this study we evaluated the Luminex LX 100 for concurrent identification of more than one PCRmore » amplified product. ANAA has real-time Taqman fluorescent detection capability for rapid identification of field samples. However, its multiplexing ability is limited by the combination of available fluorescent labels. Hence integration of ANAA with flow cytometry can give the rapidity of ANAA amplification and the multiplex capability of flow cytometry. Multiplexed flow cytometric analysis is made possible using a set of fluorescent latex microsphere that are individually identified by their red and infrared fluorescence. A green fluorochrome is used as the assay signal. Methods were developed for the identification of specific nucleic acid sequences from Bacillus globigii (Bg), Bacillus thuringensis (Bt) and Erwinia herbicola (Eh). Detection sensitivity using different reporter fluorochromes was tested with the LX 100, and also different assay formats were evaluated for their suitability for rapid testing. A blind laboratory trial was carried out December 22-27, 1999 to evaluate bead assays for multiplex identification of Bg and Bt PCR products. This report summarizes the assay development, fluorochrome comparisons, and the results of the blind trial conducted at LLNL for the laboratory evaluation of the LX 100 flow analyzer.« less
Extracting Cell Stiffness from Real-Time Deformability Cytometry: Theory and Experiment.
Mietke, Alexander; Otto, Oliver; Girardo, Salvatore; Rosendahl, Philipp; Taubenberger, Anna; Golfier, Stefan; Ulbricht, Elke; Aland, Sebastian; Guck, Jochen; Fischer-Friedrich, Elisabeth
2015-11-17
Cell stiffness is a sensitive indicator of physiological and pathological changes in cells, with many potential applications in biology and medicine. A new method, real-time deformability cytometry, probes cell stiffness at high throughput by exposing cells to a shear flow in a microfluidic channel, allowing for mechanical phenotyping based on single-cell deformability. However, observed deformations of cells in the channel not only are determined by cell stiffness, but also depend on cell size relative to channel size. Here, we disentangle mutual contributions of cell size and cell stiffness to cell deformation by a theoretical analysis in terms of hydrodynamics and linear elasticity theory. Performing real-time deformability cytometry experiments on both model spheres of known elasticity and biological cells, we demonstrate that our analytical model not only predicts deformed shapes inside the channel but also allows for quantification of cell mechanical parameters. Thereby, fast and quantitative mechanical sampling of large cell populations becomes feasible. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.
Extracting Cell Stiffness from Real-Time Deformability Cytometry: Theory and Experiment
Mietke, Alexander; Otto, Oliver; Girardo, Salvatore; Rosendahl, Philipp; Taubenberger, Anna; Golfier, Stefan; Ulbricht, Elke; Aland, Sebastian; Guck, Jochen; Fischer-Friedrich, Elisabeth
2015-01-01
Cell stiffness is a sensitive indicator of physiological and pathological changes in cells, with many potential applications in biology and medicine. A new method, real-time deformability cytometry, probes cell stiffness at high throughput by exposing cells to a shear flow in a microfluidic channel, allowing for mechanical phenotyping based on single-cell deformability. However, observed deformations of cells in the channel not only are determined by cell stiffness, but also depend on cell size relative to channel size. Here, we disentangle mutual contributions of cell size and cell stiffness to cell deformation by a theoretical analysis in terms of hydrodynamics and linear elasticity theory. Performing real-time deformability cytometry experiments on both model spheres of known elasticity and biological cells, we demonstrate that our analytical model not only predicts deformed shapes inside the channel but also allows for quantification of cell mechanical parameters. Thereby, fast and quantitative mechanical sampling of large cell populations becomes feasible. PMID:26588562
Managing Multi-center Flow Cytometry Data for Immune Monitoring
White, Scott; Laske, Karoline; Welters, Marij JP; Bidmon, Nicole; van der Burg, Sjoerd H; Britten, Cedrik M; Enzor, Jennifer; Staats, Janet; Weinhold, Kent J; Gouttefangeas, Cécile; Chan, Cliburn
2014-01-01
With the recent results of promising cancer vaccines and immunotherapy1–5, immune monitoring has become increasingly relevant for measuring treatment-induced effects on T cells, and an essential tool for shedding light on the mechanisms responsible for a successful treatment. Flow cytometry is the canonical multi-parameter assay for the fine characterization of single cells in solution, and is ubiquitously used in pre-clinical tumor immunology and in cancer immunotherapy trials. Current state-of-the-art polychromatic flow cytometry involves multi-step, multi-reagent assays followed by sample acquisition on sophisticated instruments capable of capturing up to 20 parameters per cell at a rate of tens of thousands of cells per second. Given the complexity of flow cytometry assays, reproducibility is a major concern, especially for multi-center studies. A promising approach for improving reproducibility is the use of automated analysis borrowing from statistics, machine learning and information visualization21–23, as these methods directly address the subjectivity, operator-dependence, labor-intensive and low fidelity of manual analysis. However, it is quite time-consuming to investigate and test new automated analysis techniques on large data sets without some centralized information management system. For large-scale automated analysis to be practical, the presence of consistent and high-quality data linked to the raw FCS files is indispensable. In particular, the use of machine-readable standard vocabularies to characterize channel metadata is essential when constructing analytic pipelines to avoid errors in processing, analysis and interpretation of results. For automation, this high-quality metadata needs to be programmatically accessible, implying the need for a consistent Application Programming Interface (API). In this manuscript, we propose that upfront time spent normalizing flow cytometry data to conform to carefully designed data models enables automated analysis, potentially saving time in the long run. The ReFlow informatics framework was developed to address these data management challenges. PMID:26085786
Liquid Crystal Droplet-Based Amplification of Microvesicles that are Shed by Mammalian Cells
Tan, Lie Na; Wiepz, Gregory J.; Miller, Daniel S.; Shusta, Eric V.; Abbott, Nicholas L.
2014-01-01
Membrane-derived microvesicles (MVs) shed by cells are being investigated for their role in intercellular communication and as potential biomarkers of disease, but facile and sensitive methods for their analysis do not exist. Here we demonstrate new principles for analysis of MVs that use micrometer-sized droplets of liquid crystals (LCs) to amplify MVs that are selectively captured via antibody-mediated interactions. The influence of the MVs on the micrometer-sized LC droplets is shown to be readily quantified via use of flow cytometry. The methodology was developed using MVs shed by epidermoid carcinoma A431 cells that contain epidermal growth factor receptor (EGFR) as an important and representative example of MVs containing signaling proteins that play a central role in cancer. The LC droplets were found to be sensitive to 106 MVs containing EGFR (relative to controls using isotype control antibody) and to possess a dynamic range of response across several orders of magnitude. Because the 100 nm-sized MVs captured via EGFR generate an optical response in the micrometer-sized LC droplets that can be readily detected by flow cytometry in light scattering mode, the approach possesses significant advantages over direct detection of MVs by flow cytometry. The LC droplets are also substantially more sensitive than techniques such as immunoblotting because the lipid-component of the MVs serves to amplify the antibody-mediated capture of the target proteins in the MVs. Other merits of the approach are defined and discussed in the paper. PMID:24667742
Microfluidic sorting and multimodal typing of cancer cells in self-assembled magnetic arrays.
Saliba, Antoine-Emmanuel; Saias, Laure; Psychari, Eleni; Minc, Nicolas; Simon, Damien; Bidard, François-Clément; Mathiot, Claire; Pierga, Jean-Yves; Fraisier, Vincent; Salamero, Jean; Saada, Véronique; Farace, Françoise; Vielh, Philippe; Malaquin, Laurent; Viovy, Jean-Louis
2010-08-17
We propose a unique method for cell sorting, "Ephesia," using columns of biofunctionalized superparamagnetic beads self-assembled in a microfluidic channel onto an array of magnetic traps prepared by microcontact printing. It combines the advantages of microfluidic cell sorting, notably the application of a well controlled, flow-activated interaction between cells and beads, and those of immunomagnetic sorting, notably the use of batch-prepared, well characterized antibody-bearing beads. On cell lines mixtures, we demonstrated a capture yield better than 94%, and the possibility to cultivate in situ the captured cells. A second series of experiments involved clinical samples--blood, pleural effusion, and fine needle aspirates--issued from healthy donors and patients with B-cell hematological malignant tumors (leukemia and lymphoma). The immunophenotype and morphology of B-lymphocytes were analyzed directly in the microfluidic chamber, and compared with conventional flow cytometry and visual cytology data, in a blind test. Immunophenotyping results using Ephesia were fully consistent with those obtained by flow cytometry. We obtained in situ high resolution confocal three-dimensional images of the cell nuclei, showing intranuclear details consistent with conventional cytological staining. Ephesia thus provides a powerful approach to cell capture and typing allowing fully automated high resolution and quantitative immunophenotyping and morphological analysis. It requires at least 10 times smaller sample volume and cell numbers than cytometry, potentially increasing the range of indications and the success rate of microbiopsy-based diagnosis, and reducing analysis time and cost.
Microfluidic sorting and multimodal typing of cancer cells in self-assembled magnetic arrays
Saliba, Antoine-Emmanuel; Saias, Laure; Psychari, Eleni; Minc, Nicolas; Simon, Damien; Bidard, François-Clément; Mathiot, Claire; Pierga, Jean-Yves; Fraisier, Vincent; Salamero, Jean; Saada, Véronique; Farace, Françoise; Vielh, Philippe; Malaquin, Laurent; Viovy, Jean-Louis
2010-01-01
We propose a unique method for cell sorting, “Ephesia,” using columns of biofunctionalized superparamagnetic beads self-assembled in a microfluidic channel onto an array of magnetic traps prepared by microcontact printing. It combines the advantages of microfluidic cell sorting, notably the application of a well controlled, flow-activated interaction between cells and beads, and those of immunomagnetic sorting, notably the use of batch-prepared, well characterized antibody-bearing beads. On cell lines mixtures, we demonstrated a capture yield better than 94%, and the possibility to cultivate in situ the captured cells. A second series of experiments involved clinical samples—blood, pleural effusion, and fine needle aspirates— issued from healthy donors and patients with B-cell hematological malignant tumors (leukemia and lymphoma). The immunophenotype and morphology of B-lymphocytes were analyzed directly in the microfluidic chamber, and compared with conventional flow cytometry and visual cytology data, in a blind test. Immunophenotyping results using Ephesia were fully consistent with those obtained by flow cytometry. We obtained in situ high resolution confocal three-dimensional images of the cell nuclei, showing intranuclear details consistent with conventional cytological staining. Ephesia thus provides a powerful approach to cell capture and typing allowing fully automated high resolution and quantitative immunophenotyping and morphological analysis. It requires at least 10 times smaller sample volume and cell numbers than cytometry, potentially increasing the range of indications and the success rate of microbiopsy-based diagnosis, and reducing analysis time and cost. PMID:20679245
Heo, Young Jin; Lee, Donghyeon; Kang, Junsu; Lee, Keondo; Chung, Wan Kyun
2017-09-14
Imaging flow cytometry (IFC) is an emerging technology that acquires single-cell images at high-throughput for analysis of a cell population. Rich information that comes from high sensitivity and spatial resolution of a single-cell microscopic image is beneficial for single-cell analysis in various biological applications. In this paper, we present a fast image-processing pipeline (R-MOD: Real-time Moving Object Detector) based on deep learning for high-throughput microscopy-based label-free IFC in a microfluidic chip. The R-MOD pipeline acquires all single-cell images of cells in flow, and identifies the acquired images as a real-time process with minimum hardware that consists of a microscope and a high-speed camera. Experiments show that R-MOD has the fast and reliable accuracy (500 fps and 93.3% mAP), and is expected to be used as a powerful tool for biomedical and clinical applications.
Panzer, Simon; Eichelberger, Beate; Koren, Daniela; Kaufmann, Karin; Male, Christoph
2007-01-01
Bernard-Soulier syndrome (BSS) patients may repeatedly require transfusion of platelets (PLTs). The hemostatic competence of transfused PLTs requires monitoring. Flow cytometry and a cone and plate(let) analyzer (Impact-R, DiaMed) were used to monitor survival and function of transfused PLTs in a 7-year-old girl with BSS undergoing surgery. Flow cytometry was applied to differentiate autologous PLTs from transfused PLTs by staining for CD42b. The Impact, which measures PLT adhesion and aggregation in response to high shear stress, was used to evaluate PLT function. Transfused PLTs were detectable by flow cytometry for 1 week after transfusion. While the patient's PLTs did not respond to high shear stress before transfusion, a normal response was documented by the Impact on the day after transfusion and 1 week thereafter. Transfused PLTs were detectable by flow cytometry, and their functional activity was demonstrated by the Impact.
Leukocyte Populations in Human Preterm and Term Breast Milk Identified by Multicolour Flow Cytometry
Trend, Stephanie; de Jong, Emma; Lloyd, Megan L.; Kok, Chooi Heen; Richmond, Peter; Doherty, Dorota A.; Simmer, Karen; Kakulas, Foteini; Strunk, Tobias; Currie, Andrew
2015-01-01
Background Extremely preterm infants are highly susceptible to bacterial infections but breast milk provides some protection. It is unknown if leukocyte numbers and subsets in milk differ between term and preterm breast milk. This study serially characterised leukocyte populations in breast milk of mothers of preterm and term infants using multicolour flow cytometry methods for extended differential leukocyte counts in blood. Methods Sixty mothers of extremely preterm (<28 weeks gestational age), very preterm (28–31 wk), and moderately preterm (32–36 wk), as well as term (37–41 wk) infants were recruited. Colostrum (d2–5), transitional (d8–12) and mature milk (d26–30) samples were collected, cells isolated, and leukocyte subsets analysed using flow cytometry. Results The major CD45+ leukocyte populations circulating in blood were also detectable in breast milk but at different frequencies. Progression of lactation was associated with decreasing CD45+ leukocyte concentration, as well as increases in the relative frequencies of neutrophils and immature granulocytes, and decreases in the relative frequencies of eosinophils, myeloid and B cell precursors, and CD16- monocytes. No differences were observed between preterm and term breast milk in leukocyte concentration, though minor differences between preterm groups in some leukocyte frequencies were observed. Conclusions Flow cytometry is a useful tool to identify and quantify leukocyte subsets in breast milk. The stage of lactation is associated with major changes in milk leukocyte composition in this population. Fresh preterm breast milk is not deficient in leukocytes, but shorter gestation may be associated with minor differences in leukocyte subset frequencies in preterm compared to term breast milk. PMID:26288195
Kavak, A; Johannisson, A; Lundeheim, N; Rodriguez-Martinez, H; Aidnik, M; Einarsson, S
2003-04-15
Methods to evaluate the quality of frozen-thawed stallion semen are still needed, particularly those considering the sperm function. The present study evaluated sperm motility, membrane and acrosome integrity and the capacitation status of frozen-thawed spermatozoa from seven Tori and six Estonian breed stallions by way of computer assisted sperm analysis (CASA), a triple fluorophore stain combination and Merocyanine 540, respectively, the latter ones using flow cytometry. Two ejaculates from each stallion were cryopreserved using the Hannover method in 0.5 ml plastic straws. Two straws per ejaculate per stallion were thawed at 37 degrees C for 30s. Motility was analysed with CASA immediately after thawing, while for flow cytometry spermatozoa were cleansed by 70:40% Percoll discontinuous density gradient separation before analysed for sperm viability, acrosome integrity (stained with SNARF, PI and FITC-PSA) and capacitation status (stained with Merocyanine 540/Yo-Pro-1). Results (as least square means) were as follows: the motility of frozen-thawed semen was 43.4% for Tori stallions and 42.3% for Estonian stallions (P>0.05). After Percoll separation 79.3% of the spermatozoa from Tori stallions had intact acrosomes and 1.7% of them showed early signs of capacitation. The same parameters for Estonian stallions were 84.5 and 2.3%, respectively. There were no statistically significant differences between breeds or ejaculates within breed for any evaluated parameter. We conclude that triple staining and flow cytometry are valuable techniques to evaluate frozen-thawed stallion spermatozoa, and that no differences in quality of frozen semen were registered between Tori and Estonian breed stallions, allowing implementation of this technology in the Estonian horse population.
Sousa, Susana; Cardoso, Luís; Reed, Steven G.; Reis, Alexandre B.; Martins-Filho, Olindo A.; Silvestre, Ricardo; Cordeiro da Silva, Anabela
2013-01-01
Background An accurate diagnosis is essential for the control of infectious diseases. In the search for effective and efficient tests, biosensors have increasingly been exploited for the development of new and highly sensitive diagnostic methods. Here, we describe a new fluorescent based immunosensor comprising magnetic polymer microspheres coated with recombinant antigens to improve the detection of specific antibodies generated during an infectious disease. As a challenging model, we used canine leishmaniasis due to the unsatisfactory sensitivity associated with the detection of infection in asymptomatic animals where the levels of pathogen-specific antibodies are scarce. Methodology Ni-NTA magnetic microspheres with 1,7 µm and 8,07 µm were coated with the Leishmania recombinant proteins LicTXNPx and rK39, respectively. A mixture of equal proportions of both recombinant protein-coated microspheres was used to recognize and specifically bind anti-rK39 and anti-LicTNXPx antibodies present in serum samples of infected dogs. The microspheres were recovered by magnetic separation and the percentage of fluorescent positive microspheres was quantified by flow cytometry. Principal Findings A clinical evaluation carried out with 129 dog serum samples using the antigen combination demonstrated a sensitivity of 98,8% with a specificity of 94,4%. rK39 antigen alone demonstrated a higher sensitivity for symptomatic dogs (96,9%), while LicTXNPx antigen showed a higher sensitivity for asymptomatic (94,4%). Conclusions Overall, our results demonstrated the potential of a magnetic microsphere associated flow cytometry methodology as a viable tool for highly sensitive laboratorial serodiagnosis of both clinical and subclinical forms of canine leishmaniasis. PMID:23991232
Detection of microparticles from human red blood cells by multiparametric flow cytometry
Grisendi, Giulia; Finetti, Elena; Manganaro, Daniele; Cordova, Nicoletta; Montagnani, Giuliano; Spano, Carlotta; Prapa, Malvina; Guarneri, Valentina; Otsuru, Satoru; Horwitz, Edwin M.; Mari, Giorgio; Dominici, Massimo
2015-01-01
Background During storage, red blood cells (RBC) undergo chemical and biochemical changes referred to as “storage lesions”. These events determine the loss of RBC integrity, resulting in lysis and release of microparticles. There is growing evidence of the clinical importance of microparticles and their role in blood transfusion-related side effects and pathogen transmission. Flow cytometry is currently one of the most common techniques used to quantify and characterise microparticles. Here we propose multiparametric staining to monitor and quantify the dynamic release of microparticles by stored human RBC. Material and methods RBC units (n=10) were stored under blood bank conditions for up to 42 days. Samples were tested at different time points to detect microparticles and determine the haemolysis rate (HR%). Microparticles were identified by flow cytometry combining carboxyfluorescein diacetate succinimidyl ester (CFSE) dye, annexin V and anti-glycophorin A antibody. Results We demonstrated that CFSE can be successfully used to label closed vesicles with an intact membrane. The combination of CFSE and glycophorin A antibody was effective for monitoring and quantifying the dynamic release of microparticles from RBC during storage. Double staining with CFSE/glycophorin A was a more precise approach, increasing vesicle detection up to 4.7-fold vs the use of glycophorin A/annexin V alone. Moreover, at all the time points tested, we found a robust correlation (R=0.625; p=0.0001) between HR% and number of microparticles detected. Discussion Multiparametric staining, based on a combination of CFSE, glycophorin A antibody and annexin V, was able to detect, characterise and monitor the release of microparticles from RBC units during storage, providing a sensitive approach to labelling and identifying microparticles for transfusion medicine and, more broadly, for cell-based therapies. PMID:25369588
Reyes-Núñez, Virginia; Galo-Hooker, Evelyn; Pérez-Romano, Beatriz; Duque, Ricardo E; Ruiz-Arguelles, Alejandro; Garcés-Eisele, Javier
2018-01-01
The aim of this work was to simultaneously use multiplex ligation-dependent probe amplification (MLPA) assay and flow cytometric DNA ploidy analysis (FPA) to detect aneuploidy in patients with newly diagnosed acute leukemia. MLPA assay and propidium iodide FPA were used to test samples from 53 consecutive patients with newly diagnosed acute leukemia referred to our laboratory for immunophenotyping. Results were compared by nonparametric statistics. The combined use of both methods significantly increased the rate of detection of aneuploidy as compared to that obtained by each method alone. The limitations of one method are somehow countervailed by the other and vice versa. MPLA and FPA yield different yet complementary information concerning aneuploidy in acute leukemia. The simultaneous use of both methods might be recommended in the clinical setting. © 2017 International Clinical Cytometry Society. © 2017 International Clinical Cytometry Society.
DNA polymorphism identity determination using flow cytometry
Nolan, John P.; White, P. Scott; Cai, Hong
2001-01-01
DNA polymorphism identity determination using flow cytometry. Primers designed to be immobilized on microspheres are allowed to anneal to the DNA strand under investigation, and are extended by either DNA polymerase using fluorescent dideoxynucleotides or ligated by DNA ligase to fluorescent reporter oligonucleotides. The fluorescence of either the dideoxynucleotide or the reporter oligonucleotide attached to the immobilized primer is measured by flow cytometry, thereby identifying the nucleotide polymorphism on the DNA strand.
Early Detection of NSCLC Using Stromal Markers in Peripheral Blood
2016-09-01
circulating myeloid cells, flow cytometry, RNA -sequencing, expression profiling. 3. ACCOMPLISHMENTS: What were the major goals of the project...Subtask 2: Flow cytometry sorting of circulating myeloid cells. Subtask 3: RNA -Sequencing Subtask 4: RNA -seq data analysis Subtask 5: Feasible RT-PCR...accomplished the patient recruitment, flow cytometry sorting of circulating myeloid cells, RNA -sequencing of the samples. During the RNA - seq data analysis, we
Ford, C H; Tsaltas, G C; Osborne, P A; Addetia, K
1996-03-01
A flow cytometric method of studying the internalization of a monoclonal antibody (Mab) directed against carcinoembryonic antigen (CEA) has been compared with Western blotting, using three human colonic cancer cell lines which express varying amounts of the target antigen. Cell samples incubated for increasing time intervals with fluoresceinated or unlabelled Mab were analyzed using flow cytometry or polyacrylamide gel electrophoresis and Western blotting. SDS/PAGE analysis of cytosolic and membrane components of solubilized cells from the cell lines provided evidence of non-degraded internalized anti-CEA Mab throughout seven half hour intervals, starting at 5 min. Internalized anti-CEA was detected in the case of high CEA expressing cell lines (LS174T, SKCO1). Very similar results were obtained with an anti-fluorescein flow cytometric assay. Given that these two methods consistently provided comparable results, use of flow cytometry for the detection of internalized antibody is suggested as a rapid alternative to most currently used methods for assessing antibody internalization. The question of the endocytic route followed by CEA-anti-CEA complexes was addressed by using hypertonic medium to block clathrin mediated endocytosis.
Ting, Y S; Smith, S A B C; Brown, D A; Dodds, A J; Fay, K C; Ma, D D F; Milliken, S; Moore, J J; Sewell, W A
2018-05-27
Immunophenotyping by flow cytometry is routinely employed in distinguishing between chronic lymphocytic leukemia (CLL) and mantle cell lymphoma (MCL). Inclusion of CD200 has been reported to contribute to more reliable differentiation between CLL and MCL. We investigated the value of CD200 in assessment of atypical CLL cases. CD200 expression on mature B cell neoplasms was studied by eight-color flow cytometry in combination with a conventional panel of flow cytometry markers. The study included 70 control samples, 63 samples with CLL or atypical CLL phenotype, 6 MCL samples, and 40 samples of other mature B cell neoplasms. All CLL samples were positive for CD200, whereas MCL samples were dim or negative for CD200. Of the CLL samples, 7 were atypical by conventional flow cytometry, with Matutes scores ≤3. These cases were tested for evidence of a t(11;14) translocation, characteristic of MCL, and all were negative, consistent with their classification as atypical CLL. All these atypical CLL samples were strongly positive for CD200. CD200 proved to be a useful marker for differentiation between CLL and MCL by flow cytometry. In particular, CD200 was useful in distinguishing CLL samples with atypical immunophenotypes from MCL. © 2018 John Wiley & Sons Ltd.
Davis, Bruce H; Dasgupta, Amar; Kussick, Steven; Han, Jin-Yeong; Estrellado, Annalee
2013-01-01
Flow cytometry and other technologies of cell-based fluorescence assays are as a matter of good laboratory practice required to validate all assays, which when in clinical practice may pass through regulatory review processes using criteria often defined with a soluble analyte in plasma or serum samples in mind. Recently the U.S. Food and Drug Administration (FDA) has entered into a public dialogue in the U.S. regarding their regulatory interest in laboratory developed tests (LDTs) or so-called "home brew" assays performed in clinical laboratories. The absence of well-defined guidelines for validation of cell-based assays using fluorescence detection has thus become a subject of concern for the International Council for Standardization of Haematology (ICSH) and International Clinical Cytometry Society (ICCS). Accordingly, a group of over 40 international experts in the areas of test development, test validation, and clinical practice of a variety of assay types using flow cytometry and/or morphologic image analysis were invited to develop a set of practical guidelines useful to in vitro diagnostic (IVD) innovators, clinical laboratories, regulatory scientists, and laboratory inspectors. The focus of the group was restricted to fluorescence reporter reagents, although some common principles are shared by immunohistochemistry or immunocytochemistry techniques and noted where appropriate. The work product of this two year effort is the content of this special issue of this journal, which is published as 5 separate articles, this being Validation of Cell-based Fluorescence Assays: Practice Guidelines from the ICSH and ICCS - Part II - Preanalytical issues. © 2013 International Clinical Cytometry Society. © 2013 International Clinical Cytometry Society.
Flow Cytometry in Diagnosis of Myelomatous Pleural Effusion: A Case Report.
Arora, Parul; Gupta, Sanjeev Kumar; Mallik, Nabhajit; Mittal, Reena; Sharma, Om Dutt; Kumar, Lalit
2016-06-01
Plasma cell myeloma is a multifocal plasma cell neoplasm associated with increased monoclonal protein in serum and/or urine. Pleural effusions in patients with myeloma are uncommon (6 %). However, effusions due to direct infiltration of the pleura by plasma cells (myelomatous pleural effusion) are extremely rare (<1 %) and usually seen with IgA myeloma. The diagnosis of such cases requires pleural fluid cytology, electrophoresis or pleural biopsy. We present a case of myelomatous pleural effusion diagnosed using flow cytometry immunophenotyping in addition to the pleural fluid cytology. A 45 year old female was diagnosed as plasma cell myeloma (IgG kappa) in 2007. She received multiple lines of therapy during the course of her treatment including thalidomide, dexamethasone, lenalidomide, bortezomib, and doxorubicin based regimens. However, the patient had progressive extramedullary disease and developed pleural effusion in 2014. Cytological examination of the pleural fluid showed degenerative changes. Few preserved areas showed mononuclear cells including morphologically abnormal plasma cells. Immunophenotyping of these cells by flow cytometry revealed a pattern indicating neoplastic plasma cells. There was expression of CD38, CD138, and CD56, with absence of CD19, CD10 and CD45. This confirmed the diagnosis of myelomatous pleural effusion. Subsequently, the patient was offered a dexamethasone, cyclophosphamide, etoposide and cisplatin based regimen but, she declined further treatment and succumbed to her disease 3 months later. Myelomatous pleural effusion is a rare complication of plasma cell myeloma. Flow cytometry can be used as an adjunctive technique in its diagnosis particularly in cases with equivocal cytology and electrophoresis findings.
Guo, Ling; Wang, Zhen; Anderson, Courtney M; Doolittle, Emerald; Kernag, Siobhan; Cotta, Claudiu V; Ondrejka, Sarah L; Ma, Xiao-Jun; Cook, James R
2018-03-01
The assessment of B-cell clonality is a critical component of the evaluation of suspected lymphoproliferative disorders, but analysis from formalin-fixed, paraffin-embedded tissues can be challenging if fresh tissue is not available for flow cytometry. Immunohistochemical and conventional bright field in situ hybridization stains for kappa and lambda are effective for evaluation of plasma cells but are often insufficiently sensitive to detect the much lower abundance of light chains present in B-cells. We describe an ultrasensitive RNA in situ hybridization assay that has been adapted for use on an automated immunohistochemistry platform and compare results with flow cytometry in 203 consecutive tissues and 104 consecutive bone marrows. Overall, in 203 tissue biopsies, RNA in situ hybridization identified light chain-restricted B-cells in 85 (42%) vs 58 (29%) by flow cytometry. Within 83 B-cell non-Hodgkin lymphomas, RNA in situ hybridization identified restricted B-cells in 74 (89%) vs 56 (67%) by flow cytometry. B-cell clonality could be evaluated in only 23/104 (22%) bone marrow cases owing to poor RNA preservation, but evaluable cases showed 91% concordance with flow cytometry. RNA in situ hybridization allowed for recognition of biclonal/composite lymphomas not identified by flow cytometry and highlighted unexpected findings, such as coexpression of kappa and lambda RNA in 2 cases and the presence of lambda light chain RNA in a T lymphoblastic lymphoma. Automated RNA in situ hybridization showed excellent interobserver reproducibility for manual evaluation (average K=0.92), and an automated image analysis system showed high concordance (97%) with manual evaluation. Automated RNA in situ hybridization staining, which can be adopted on commonly utilized immunohistochemistry instruments, allows for the interpretation of clonality in the context of the morphological features in formalin-fixed, paraffin-embedded tissues with a clinical sensitivity similar or superior to flow cytometry.
Guo, Ling; Wang, Zhen; Anderson, Courtney M.; Doolittle, Emerald; Kernag, Siobhan; Cotta, Claudiu V.; Ondrejka, Sarah L.; Ma, Xiao-Jun; Cook, James R.
2017-01-01
The assessment of B-cell clonality is a critical component of the evaluation of suspected lymphoproliferative disorders, but analysis from formalin fixed paraffin embedded tissues can be challenging if fresh tissue is not available for flow cytometry. Immunohistochemical and conventional bright field in situ hybridization stains for kappa and lambda are effective for evaluation of plasma cells, but are often insufficiently sensitive to detect the much lower abundance of light chains present in B cells. We describe an ultrasensitive RNA in situ hybridization assay which has been adapted for use on an automated immunohistochemistry platform and compare results with flow cytometry in 203 consecutive tissues and 104 consecutive bone marrows. Overall, in 203 tissue biopsies, RNA in situ hybridization identified light chain restricted B-cells in 85 (42%) vs. 58 (29%) by flow cytometry. Within 83 B-cell non-Hodgkin lymphomas, RNA in situ hybridization identified a restricted B-cells in 74 (89%) vs. 56 (67%) by flow cytometry. B-cell clonality could be evaluated in only 23/104 (22%) bone marrow cases due to poor RNA preservation, but evaluable cases showed 91% concordance with flow cytometry. RNA in situ hybridization allowed for recognition of biclonal/composite lymphomas not identified by flow cytometry, and highlighted unexpected findings, such as coexpression of kappa and lambda RNA in 2 cases and the presence of lambda light chain RNA in a T lymphoblastic lymphoma. Automated RNA in situ hybridization showed excellent interobserver reproducibility for manual evaluation (average K=0.92), and an automated image analysis system showed high concordance (97%) with manual evaluation. Automated RNA in situ hybridization staining, which can be adopted on commonly utilized immunohistochemistry instruments, allows for the interpretation of clonality in the context of the morphologic features in formalin fixed, paraffin embedded tissues with a clinical sensitivity similar or superior to flow cytometry. PMID:29052600
Altered immunophenotypic features of peripheral blood platelets in myelodysplastic syndromes
Sandes, Alex F.; Yamamoto, Mihoko; Matarraz, Sergio; Chauffaille, Maria de Lourdes L.F.; Quijano, Sandra; López, Antonio; Oguro, Tsutomu; Kimura, Eliza Y. S.; Orfao, Alberto
2012-01-01
Background Multiparameter flow cytometric analysis of bone marrow and peripheral blood cells has proven to be of help in the diagnostic workup of myelodysplastic syndromes. However, the usefulness of flow cytometry for the detection of megakaryocytic and platelet dysplasia has not yet been investigated. The aim of this pilot study was to evaluate by flow cytometry the diagnostic and prognostic value of platelet dysplasia in myelodysplastic syndromes. Design and Methods We investigated the pattern of expression of distinct surface glycoproteins on peripheral blood platelets from a series of 44 myelodysplastic syndrome patients, 20 healthy subjects and 19 patients with platelet alterations associated to disease conditions other than myelodysplastic syndromes. Quantitative expression of CD31, CD34, CD36, CD41a, CD41b, CD42a, CD42b and CD61 glycoproteins together with the PAC-1, CD62-P, fibrinogen and CD63 platelet activation-associated markers and platelet light scatter properties were systematically evaluated. Results Overall, flow cytometry identified multiple immunophenotypic abnormalities on platelets of myelodysplastic syndrome patients, including altered light scatter characteristics, over-and under expression of specific platelet glycoproteins and asynchronous expression of CD34; decreased expression of CD36 (n=5), CD42a (n=1) and CD61 (n=2), together with reactivity for CD34 (n=1) were only observed among myelodysplastic syndrome cases, while other alterations were also found in other platelet disorders. Based on the overall platelet alterations detected for each patient, an immunophenotypic score was built which identified a subgroup of myelodysplastic syndrome patients with a high rate of moderate to severe alterations (score>1.5; n=16) who more frequently showed thrombocytopenia, megakaryocytic dysplasia and high-risk disease, together with a shorter overall survival. Conclusions Our results show the presence of altered phenotypes by flow cytometry on platelets from around half of the myelodysplastic syndrome patients studied. If confirmed in larger series of patients, these findings may help refine the diagnostic and prognostic assessment of this group of disorders. PMID:22271903
Suzuki, Miho; Sakata, Ichiro; Sakai, Takafumi; Tomioka, Hiroaki; Nishigaki, Koichi; Tramier, Marc; Coppey-Moisan, Maïté
2015-12-15
Cytometry is a versatile and powerful method applicable to different fields, particularly pharmacology and biomedical studies. Based on the data obtained, cytometric studies are classified into high-throughput (HTP) or high-content screening (HCS) groups. However, assays combining the advantages of both are required to facilitate research. In this study, we developed a high-throughput system to profile cellular populations in terms of time- or dose-dependent responses to apoptotic stimulations because apoptotic inducers are potent anticancer drugs. We previously established assay systems involving protease to monitor live cells for apoptosis using tunable fluorescence resonance energy transfer (FRET)-based bioprobes. These assays can be used for microscopic analyses or fluorescence-activated cell sorting. In this study, we developed FRET-based bioprobes to detect the activity of the apoptotic markers caspase-3 and caspase-9 via changes in bioprobe fluorescence lifetimes using a flow cytometer for direct estimation of FRET efficiencies. Different patterns of changes in the fluorescence lifetimes of these markers during apoptosis were observed, indicating a relationship between discrete steps in the apoptosis process. The findings demonstrate the feasibility of evaluating collective cellular dynamics during apoptosis. Copyright © 2015 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Zhog, Cheng Frank; Ye, Jing Yong; Norris, Theodore B.; Myc, Andrzej; Cao, Zhengyl; Bielinska, Anna; Thomas, Thommey; Baker, James R., Jr.
2004-01-01
Flow cytometry is a powerful technique for obtaining quantitative information from fluorescence in cells. Quantitation is achieved by assuring a high degree of uniformity in the optical excitation and detection, generally by using a highly controlled flow such as is obtained via hydrodynamic focusing. In this work, we demonstrate a two-beam, two- channel detection and two-photon excitation flow cytometry (T(sup 3)FC) system that enables multi-dye analysis to be performed very simply, with greatly relaxed requirements on the fluid flow. Two-photon excitation using a femtosecond near-infrared (NIR) laser has the advantages that it enables simultaneous excitation of multiple dyes and achieves very high signal-to-noise ratio through simplified filtering and fluorescence background reduction. By matching the excitation volume to the size of a cell, single-cell detection is ensured. Labeling of cells by targeted nanoparticles with multiple fluorophores enables normalization of the fluorescence signal and thus ratiometric measurements under nonuniform excitation. Quantitative size measurements can also be done even under conditions of nonuniform flow via a two-beam layout. This innovative detection scheme not only considerably simplifies the fluid flow system and the excitation and collection optics, it opens the way to quantitative cytometry in simple and compact microfluidics systems, or in vivo. Real-time detection of fluorescent microbeads in the vasculature of mouse ear demonstrates the ability to do flow cytometry in vivo. The conditions required to perform quantitative in vivo cytometry on labeled cells will be presented.
Dynamic thermoregulation of the sample in flow cytometry.
Graves, Steven W; Habbersett, Robert C; Nolan, John P
2002-05-01
Fine control of temperature is an important capability for any analytical platform. A circulating water bath has been the traditional means of maintaining constant temperature in the sample chamber of a flow cytometer, but this approach does not permit rapid changes in sample temperature. This unit explains the use of Peltier modules for regulation of sample temperature. The heat pumping generated by the passage of current through properly matched semiconductors, known as the Peltier effect, makes it possible for these thermoelectric modules to both heat and cool. The authors describe the construction of a Peltier module based thermoregulation unit in step-by-step detail and present a demonstration of flow cytometry measurements as a function of temperature.
Hayama, Tomonari; Yamaguchi, Tomoyuki; Kato-Itoh, Megumi; Ishii, Yumiko; Mizuno, Naoaki; Umino, Ayumi; Sato, Hideyuki; Sanbo, Makoto; Hamanaka, Sanae; Masaki, Hideki; Hirabayashi, Masumi; Nakauchi, Hiromitsu
2016-06-01
Round spermatid injection (ROSI) into unfertilized oocytes enables a male with a severe spermatogenesis disorder to have children. One limitation of the application of this technique in the clinic is the identification and isolation of round spermatids from testis tissue. Here we developed an efficient and simple method to isolate rodent haploid round spermatids using flow cytometric cell sorting, based on DNA content (stained with Hoechst 33342 or Dye Cycle Violet) or by cell diameter and granularity (forward and side scatter). ROSI was performed with round spermatids selected by flow cytometry, and we obtained healthy offspring from unstained cells. This non-invasive method could therefore be an effective option for breeding domestic animals and human male infertility treatment. Mol. Reprod. Dev. 83: 488-496, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Genomic Instability at Premalignant and Early Stages of Breast Cancer Development
1999-08-01
by routine DNA flow cytometry vation. ERBB2 expression was detected with a to determine DNA index (DI). commercially available antibody (Oncogene Sci...supplements the information gained from ic microsatellite primers. We observed that the ploidy analysis by DNA flow cytometry alone. In DNA so obtained...preserved the proportionality of many cases where flow cytometry could not be per- the different alleles as found in the original sample. formed because the
Inhibition of Breast Cancer-Induced Angiogenesis by a Diverged Homeobox Gene
2006-05-01
and then harvested for flow cytometry using appropriate antibodies. Ad.Gax blocked the expression of VCAM-1, E-selectin, and ICAM-1. DOD Idea Award...solution. Bands were visualized by chemiluminescence using the ECL-Plus reagent (Amersham, Piscataway, NJ). Flow Cytometry Cells were harvested after...33), all of whose down-regulation we have confirmed using real time quantitative RT-PCR, Western blot, and flow cytometry (Fig. 5). Moreover, Gax
Flow Cytometry Technician | Center for Cancer Research
PROGRAM DESCRIPTION The Basic Science Program (BSP) pursues independent, multidisciplinary research in basic and applied molecular biology, immunology, retrovirology, cancer biology, and human genetics. Research efforts and support are an integral part of the Center for Cancer Research (CCR) at the Frederick National Laboratory for Cancer Research (FNLCR). KEY ROLES/RESPONSIBILITIES The Flow Cytometry Core (Flow Core) of the Cancer and Inflammation Program (CIP) is a service core which supports the research efforts of the CCR by providing expertise in the field of flow cytometry (using analyzers and sorters) with the goal of gaining a more thorough understanding of the biology of cancer and cancer cells. The Flow Core provides service to 12-15 CIP laboratories and more than 22 non-CIP laboratories. Flow core staff provide technical advice on the experimental design of applications, which include immunological phenotyping, cell function assays, and cell cycle analysis. Work is performed per customer requirements, and no independent research is involved. The Flow Cytometry Technician will be responsible for: Monitor performance of and maintain high dimensional flow cytometer analyzers and cell sorters Operate high dimensional flow cytometer analyzers and cell sorters Monitoring lab supply levels and order lab supplies, perform various record keeping responsibilities Assist in the training of scientific end users on the use of flow cytometry in their research, as well as how to operate and troubleshoot the bench-top analyzer instruments Experience with sterile technique and tissue culture
Leptomeningeal metastases: a RANO proposal for response criteria
Junck, Larry; Brandsma, Dieta; Soffietti, Riccardo; Rudà, Roberta; Raizer, Jeffrey; Boogerd, Willem; Taillibert, Sophie; Groves, Morris D.; Rhun, Emilie Le; Walker, Julie; van den Bent, Martin; Wen, Patrick Y.; Jaeckle, Kurt A.
2017-01-01
Abstract Leptomeningeal metastases (LM) currently lack standardization with respect to response assessment. A Response Assessment in Neuro-Oncology (RANO) working group with expertise in LM developed a consensus proposal for evaluating patients treated for this disease. Three basic elements in assessing response in LM are proposed: a standardized neurological examination, cerebral spinal fluid (CSF) cytology or flow cytometry, and radiographic evaluation. The group recommends that all patients enrolling in clinical trials undergo CSF analysis (cytology in all cancers; flow cytometry in hematologic cancers), complete contrast-enhanced neuraxis MRI, and in instances of planned intra-CSF therapy, radioisotope CSF flow studies. In conjunction with the RANO Neurological Assessment working group, a standardized instrument was created for assessing the neurological exam in patients with LM. Considering that most lesions in LM are nonmeasurable and that assessment of neuroimaging in LM is subjective, neuroimaging is graded as stable, progressive, or improved using a novel radiological LM response scorecard. Radiographic disease progression in isolation (ie, negative CSF cytology/flow cytometry and stable neurological assessment) would be defined as LM disease progression. The RANO LM working group has proposed a method of response evaluation for patients with LM that will require further testing, validation, and likely refinement with use. PMID:28039364
Flow Cytometry Detection of Infectious Rotaviruses in Environmental and Clinical Samples
Abad, F. Xavier; Pintó, Rosa M.; Bosch, Albert
1998-01-01
A method for the detection of infectious human rotaviruses based on infection of CaCo-2 cells and detection of infected cells by indirect immunofluorescence and flow cytometry (IIF-FC) has been developed. The technique was validated by performing a seminested reverse transcription-PCR assay with sorted cell populations. The efficiency of the procedure has been compared with that of the standard method of infection of MA104 cells and ulterior detection by IIF and optical microscopy (IIF-OM) and with that of infection of MA104 cells and detection by IIF-FC. The limit of sensitivity for the detection of the cell-adapted strain Itor P13, expressed as the most probable number of cytopathogenic units, was established as 200 and 2 for MA104 and CaCo-2 cells, respectively, by the IIF-FC method. The ratio of infectious virus particles to total virus particles for a wild-type rotavirus was determined to be 1/2 × 106 and 1/2 × 104 for IIF-OM with MA104 cells and IIF-FC with CaCo-2 cells, respectively. The use of IIF-FC with CaCo-2 cells was tested with fecal and water samples and proved to be more effective than the standard procedure for rotavirus detection. PMID:9647805
Fluorescence molecular painting of enveloped viruses.
Metzner, Christoph; Kochan, Feliks; Dangerfield, John A
2013-01-01
In this study, we describe a versatile, flexible, and quick method to label different families of enveloped viruses with glycosylphosphatidylinositol-modified green fluorescent protein, termed fluorescence molecular painting (FMP). As an example for a potential application, we investigated virus attachment by means of flow cytometry to determine if viral binding behavior may be analyzed after FMP of enveloped viruses. Virus attachment was inhibited by using either dextran sulfate or by blocking attachment sites with virus pre-treatment. Results from the FMP-flow cytometry approach were verified by immunoblotting and enzyme-linked immunosorbent assay. Since the modification strategy is applicable to a broad range of proteins and viruses, variations of this method may be useful in a range of research and applied applications from bio-distribution studies to vaccine development and targeted infection for gene delivery.
Nguefack, J; Budde, B B; Jakobsen, M
2004-01-01
To investigate the antibacterial effect of five essential oils (EO) extracted from aromatic plants (Cymbopogon citratus, Ocimumbasilicum, Ocimum gratissimum, Thymus vulgaris and Zingiber officinale) of Cameroon against strains of Listeria monocytogenes, L. innocua and Staphylococcus aureus. The ability of selected EO to permeabilize the cytoplasmic membrane of L. innocua was also examined. The antibacterial activity of the EO determined by the agar diffusion method showed that T. vulgaris had the highest activity followed by O. gratissimum and C. citratus. Lowest activity was recorded from Z. officinale and O. basilicum. Significant differences in sensitivity between strains of Listeria and S. aureus were observed. Flow cytometry of L. innocua stained with carboxy-fluorescein diacetate showed that the fluorescence intensity of cells exposed to EO decreased faster than nonexposed cells, indicating that EO permeabilized the cytoplasmic membrane with the leakage of carboxy-fluorescein. Almost all the EO tested showed antibacterial activity to a different extent. The antibacterial effect was due to permeabilization of the cytoplasmic membrane. This study has identified the preservative potential of the EO examined. The use of sensitive method, such as flow cytometry, is advantageous for quick generation of data on the antibacterial effect of EO.
Measuring T cell-mediated cytotoxicity using fluorogenic caspase substrates.
Chahroudi, A; Silvestri, G; Feinberg, M B
2003-10-01
Cytotoxic T lymphocytes (CTLs) play a major role in the immune response against viruses and other intracellular pathogens. In addition, CTLs are implicated in the control of tumor cells in certain settings. Accurate measures of CTL function are of critical importance to study the pathogenesis of infectious diseases and to evaluate the efficacy of new vaccines and immunotherapies. To this end, we have recently developed a flow cytometry-based CTL (FCC) assay that measures the CTL-induced caspase activation within target cells using cell permeable fluorogenic caspase substrates. This novel assay reliably detects, by flow cytometry or fluorescence/confocal microscopy, antigen-specific CTLs in a wide variety of human and murine systems, and is safer and more informative than the standard 51Cr-release assay. In addition, the flow cytometric CTL (FCC) assay provides an alternative method that is often more sensitive and physiologically informative when compared to previously described FCC assays, as it measures a biological indicator of apoptosis within the target cell. The FCC assay may thus represent a useful tool to further understand the molecular and cellular mechanisms that underlie CTL-mediated killing during tumorigenesis or following infection with viruses or other intracellular pathogens.
CytometryML binary data standards
NASA Astrophysics Data System (ADS)
Leif, Robert C.
2005-03-01
CytometryML is a proposed new Analytical Cytology (Cytomics) data standard, which is based on a common set of XML schemas for encoding flow cytometry and digital microscopy text based data types (metadata). CytometryML schemas reference both DICOM (Digital Imaging and Communications in Medicine) codes and FCS keywords. Flow Cytometry Standard (FCS) list-mode has been mapped to the DICOM Waveform Information Object. The separation of the large binary data objects (list mode and image data) from the XML description of the metadata permits the metadata to be directly displayed, analyzed, and reported with standard commercial software packages; the direct use of XML languages; and direct interfacing with clinical information systems. The separation of the binary data into its own files simplifies parsing because all extraneous header data has been eliminated. The storage of images as two-dimensional arrays without any extraneous data, such as in the Adobe Photoshop RAW format, facilitates the development by scientists of their own analysis and visualization software. Adobe Photoshop provided the display infrastructure and the translation facility to interconvert between the image data from commercial formats and RAW format. Similarly, the storage and parsing of list mode binary data type with a group of parameters that are specified at compilation time is straight forward. However when the user is permitted at run-time to select a subset of the parameters and/or specify results of mathematical manipulations, the development of special software was required. The use of CytometryML will permit investigators to be able to create their own interoperable data analysis software and to employ commercially available software to disseminate their data.
Near infrared lasers in flow cytometry.
Telford, William G
2015-07-01
Technology development in flow cytometry has closely tracked laser technology, the light source that flow cytometers almost exclusively use to excite fluorescent probes. The original flow cytometers from the 1970s and 1980s used large water-cooled lasers to produce only one or two laser lines at a time. Modern cytometers can take advantage of the revolution in solid state laser technology to use almost any laser wavelength ranging from the ultraviolet to the near infrared. Commercial cytometers can now be equipped with many small solid state lasers, providing almost any wavelength needed for cellular analysis. Flow cytometers are now equipped to analyze 20 or more fluorescent probes simultaneously, requiring multiple laser wavelengths. Instrument developers are now trying to increase this number by designing fluorescent probes that can be excited by laser wavelength at the "edges" of the visible light range, in the near ultraviolet and near-infrared region. A variety of fluorescent probes have been developed that excite with violet and long wavelength ultraviolet light; however, the near-infrared range (660-800 nm) has yet seen only exploitation in flow cytometry. Fortunately, near-infrared laser diodes and other solid state laser technologies appropriate for flow cytometry have been in existence for some time, and can be readily incorporated into flow cytometers to accelerate fluorescent probe development. The near infrared region represents one of the last "frontiers" to maximize the number of fluorescent probes that can be analyzed by flow cytometry. In addition, near infrared fluorescent probes used in biomedical tracking and imaging could also be employed for flow cytometry with the correct laser wavelengths. This review describes the available technology, including lasers, fluorescent probes and detector technology optimal for near infrared signal detection. Published by Elsevier Inc.
Grégori, Gérald; Rajwa, Bartek; Patsekin, Valery; Jones, James; Furuki, Motohiro; Yamamoto, Masanobu; Paul Robinson, J
2014-01-01
Hyperspectral cytometry is an emerging technology for single-cell analysis that combines ultrafast optical spectroscopy and flow cytometry. Spectral cytometry systems utilize diffraction gratings or prism-based monochromators to disperse fluorescence signals from multiple labels (organic dyes, nanoparticles, or fluorescent proteins) present in each analyzed bioparticle onto linear detector arrays such as multianode photomultipliers or charge-coupled device sensors. The resultant data, consisting of a series of characterizing every analyzed cell, are not compensated by employing the traditional cytometry approach, but rather are spectrally unmixed utilizing algorithms such as constrained Poisson regression or non-negative matrix factorization. Although implementations of spectral cytometry were envisioned as early as the 1980s, only recently has the development of highly sensitive photomultiplier tube arrays led to design and construction of functional prototypes and subsequently to introduction of commercially available systems. This chapter summarizes the historical efforts and work in the field of spectral cytometry performed at Purdue University Cytometry Laboratories and describes the technology developed by Sony Corporation that resulted in release of the first commercial spectral cytometry system-the Sony SP6800. A brief introduction to spectral data analysis is also provided, with emphasis on the differences between traditional polychromatic and spectral cytometry approaches.
Ribera, Jordi; Zamora, Lurdes; Juncà, Jordi; Rodríguez, Inés; Marcé, Silvia; Cabezón, Marta; Millá, Fuensanta
2013-07-25
In up to 5-15% of studies of lymphoproliferative disorders (LPD) flow cytometry (FCM) or immunomorphologic methods cannot discriminate malignant from reactive processes. The aim of this work was to determine the usefulness of PCR for solving these diagnostic uncertainties. We analyzed IGH and TCRγ genes by PCR in 106 samples with inconclusive FCM results. A clonal result was registered in 36/106 studies, with a LPD being confirmed in 27 (75%) of these cases. Specifically, 9/9 IGH clonal and 16/25 TCRγ clonal results were finally diagnosed with LPD. Additionally, 2 clonal TCRγ samples with suspicion of undefined LPD were finally diagnosed with T LPD. Although polyclonal results were obtained in 47 of the cases studied (38 IGH and 9 TCRγ), hematologic neoplasms were diagnosed in 4/38 IGH polyclonal and in 1/9 TCRγ polyclonal studies. There were also 14 PCR polyclonal results (4 IGH, 10 TCRγ), albeit non-conclusive. Of these, 2/4 were eventually diagnosed with B-cell lymphoma and 3/10 with T-cell LPD. In 8 IGH samples the results of PCR techniques were non-informative but in 3/8 cases a B lymphoma was finally confirmed. We concluded that PCR is a useful technique to identify LPD when FCM is inconclusive. A PCR clonal B result is indicative of malignancy but IGH polyclonal and non-conclusive results do not exclude lymphoid neoplasms. Interpretation of T-cell clonality should be based on all the available clinical and analytical data. © 2013 Clinical Cytometry Society. Copyright © 2013 Clinical Cytometry Society.
Slow-Adhering Stem Cells Derived from Injured Skeletal Muscle Have Improved Regenerative Capacity
2011-08-01
images. Flow Cytometry Assay of Stem Cell Markers SASCs (1 105) isolated from noninjured or injured muscle were collected and washed twice with...muscle. Results of flow cytometry further verified Sca-1 and CD34 expression in isolated SASCs, and a greater percentage of cells were positive for Sca-1...from both injured and control noninjured muscle were analyzed using flow cytometry for the immunofluorescent signal of Sca-1 and CD34. Results
Hypoxia and Prx1 in Malignant Progression of Prostate Cancer
2006-09-01
Species (ROS) Formation The rate of ROS formation was determined by flow cytometry analysis using the probe 20,70-dichlorofluorescin diacetate (DCFH-DA...DA were subjected to 4-h hypoxia treatment. After the indicated time, fluorescent cells were analyzed by flow cytometry . Western Blot Analysis Equal...species (ROS) generation was measured by flow cytometry at 0.5, 1, 2, 3, 6, 12, or 24 h after hypoxia treatment. The rate of ROS generation increased
Thedsawad, A; Taka, O; Wanachiwanawin, W
2016-04-01
This study was to investigate the use of flow cytometry for detection and quantitation of red blood cells (RBC) bound IgG in immune hemolysis of patients with autoimmune hemolytic anaemia (AIHA) and systematic lupus erythematosus (SLE). Two to ten percent of patients with warm-autoimmune hemolytic anaemia (WAIHA) exhibit a negative direct Coombs test. Flow cytometry has been applied to detect RBC bound IgG with high accuracy, reproducibility and sensitivity. In this study 45 and 75 patients with AIHA and SLE, respectively were evaluated for RBC bound IgG by direct Coombs test and flow cytometry. Seventy-one percent (32/45) and 31% (23/75) of patients with AIHA and SLE respectively, had laboratory evidence of hemolysis. A positive flow cytometry, as defined by mean fluorescent intensity (MFI) values >0·21 and IgG molecules >28, was found in 4 of 32 (12·5%) and 4 of 23 (17·4%) patients with AIHA and SLE who had hemolysis with a negative direct Coombs test. There were very strong and strong correlations between the strength of direct Coombs test with MFI values and IgG molecules in patients with AIHA and SLE, respectively. Flow cytometry can be applied in the diagnosis of Coombs-negative hemolytic anaemia in patients with AIHA and SLE. © 2016 British Blood Transfusion Society.
Arndt, Patricia A; Garratty, George
2010-07-01
Flow cytometry operators often apply familiar white blood cell (WBC) methods when studying red blood cell (RBC) antigens and antibodies. Some WBC methods are not appropriate for RBCs, as the analysis of RBCs requires special considerations, for example, avoidance of agglutination. One hundred seventy-six published articles from 88 groups studying RBC interactions were reviewed. Three fourths of groups used at least one unnecessary WBC procedure for RBCs, and about one fourth did not use any method to prevent/disperse RBC agglutination. Flow cytometric studies were performed to determine the effect of RBC agglutination on results and compare different methods of preventing and/or dispersing agglutination. The presence of RBC agglutinates have been shown to be affected by the type of pipette tip used for mixing RBC suspensions, the number of antigen sites/RBC, the type and concentration of primary antibody, and the type of secondary antibody. For quantitation methods, for example, fetal maternal hemorrhage, the presence of agglutinates have been shown to adversely affect results (fewer fetal D+ RBCs detected). Copyright 2010 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Meehan, R. T.
1986-01-01
Understanding the role of circulating peptide hormones in the pathogenesis of space-flight induced disorders would be greatly facilitated by a method which monitors chronic levels of hormones and their effects upon in vivo cell physiology. Single and simultaneous multiparameter flow cytometry analysis was employed to identify subpopulations of mononuclear cells bearing receptors for ACTH, Endorphin, and Somatomedin-C using monoclonal antibodies and monospecific antisera with indirect immunofluorescence. Blood samples were obtained from normal donors and subjects participating in decompression chamber studies (acute stress), medical student academic examination (chronic stress), and a drug study (Dexamethasone). Preliminary results indicate most ACTH and Endorphin receptor positive cells are monocytes and B-cells, exhibit little diurnal variation but the relative percentages of receptor positive cells are influenced by exposure to various stressors and ACTH inhibition. This study demonstrates the capability of flow cytometry analysis to study cell surface hormone receptor regulation which should allow insight into neuroendocrine modulation of the immune and other cellular systems during exposure to stress or microgravity.
Biology and flow cytometry of proangiogenic hematopoietic progenitors cells.
Rose, Jonathan A; Erzurum, Serpil; Asosingh, Kewal
2015-01-01
During development, hematopoiesis and neovascularization are closely linked to each other via a common bipotent stem cell called the hemangioblast that gives rise to both hematopoietic cells and endothelial cells. In postnatal life, this functional connection between the vasculature and hematopoiesis is maintained by a subset of hematopoietic progenitor cells endowed with the capacity to differentiate into potent proangiogenic cells. These proangiogenic hematopoietic progenitors comprise a specific subset of bone marrow (BM)-derived cells that homes to sites of neovascularization and possess potent paracrine angiogenic activity. There is emerging evidence that this subpopulation of hematopoietic progenitors plays a critical role in vascular health and disease. Their angiogenic activity is distinct from putative "endothelial progenitor cells" that become structural cells of the endothelium by differentiation into endothelial cells. Proangiogenic hematopoietic progenitor cell research requires multidisciplinary expertise in flow cytometry, hematology, and vascular biology. This review provides a comprehensive overview of proangiogenic hematopoietic progenitor cell biology and flow cytometric methods to detect these cells in the peripheral blood circulation and BM. © 2014 International Society for Advancement of Cytometry.
Immunophenotyping of acute leukaemias by flow cytometry: a review.
Pamnani, R
2009-12-01
To provide an overview of the utility of flow cytometry for phenotyping of acute leukaemias and selection-of monoclonal antibodies. The literature review was obtained through internet, journals and chapters in the relevant books. Relevant articles and chapters on immunophenotyping of acute leukaemias were selected from respected international journals and books in the field of haematology and were reviewed. Complete articles relevant to the topic were selected and reviewed and the necessary information extracted for this review. Flow cytometry has been used extensively in recent years to characterise haemopoeitic malignancies and done routinely in the developed world. This technique has greatly improved the diagnosis and classification of haemopoeitic malignancies and has been recommended by World Health Organisation classification (WHO) of tumours of haemopoeitic and lymphoid tissue. Application of flow cytometry for the diagnosis of leukaemias has been recently introduced in Kenya and is currently being undertaken in research using limited but appropriate panels of monoclonal antibodies. It is hoped that findings of this research will inform the use of flow cytometry as an ancillary diagnostic technique in our resource-constrained set up.
Healey, Ryan; Naugler, Christopher; de Koning, Lawrence; Patel, Jay L
2015-01-01
We sought to improve the diagnostic efficiency of flow cytometry investigation on blood by developing data-driven ordering guidelines. Our goal was to improve flow cytometry utilization by decreasing negative testing, therefore reducing healthcare costs. We investigated several laboratory tests performed alongside flow cytometry to identify biomarkers useful in excluding non-leukemic bloods. Test results and patient demographic features were subjected to receiver-operator characteristic (ROC) curve, logistic regression and classification tree analyses to find significant predictors and develop decision rules. Our data show that, in the absence of a compelling clinical indication, flow cytometry testing is largely non-informative on bloods from patients less than 50 years of age having an absolute lymphocyte count (ALC) below 5.0 × 10(9)/L. For patients over age 50 having an ALC below this value, a ferritin value above 450 μg/L is counter-indicative of B-cell clonality. Using these guidelines, 26% of cases were correctly predicted as negative with greater than 97% accuracy.
High-speed bioimaging with frequency-division-multiplexed fluorescence confocal microscopy
NASA Astrophysics Data System (ADS)
Mikami, Hideharu; Harmon, Jeffrey; Ozeki, Yasuyuki; Goda, Keisuke
2017-04-01
We present methods of fluorescence confocal microscopy that enable unprecedentedly high frame rate of > 10,000 fps. The methods are based on a frequency-division multiplexing technique, which was originally developed in the field of communication engineering. Specifically, we achieved a broad bandwidth ( 400 MHz) of detection signals using a dual- AOD method and overcame limitations in frame rate, due to a scanning device, by using a multi-line focusing method, resulting in a significant increase in frame rate. The methods have potential biomedical applications such as observation of sub-millisecond dynamics in biological tissues, in-vivo three-dimensional imaging, and fluorescence imaging flow cytometry.
Smurthwaite, Cameron A; Hilton, Brett J; O'Hanlon, Ryan; Stolp, Zachary D; Hancock, Bryan M; Abbadessa, Darin; Stotland, Aleksandr; Sklar, Larry A; Wolkowicz, Roland
2014-01-01
The discovery of the green fluorescent protein from Aequorea victoria has revolutionized the field of cell and molecular biology. Since its discovery a growing panel of fluorescent proteins, fluorophores and fluorescent-coupled staining methodologies, have expanded the analytical capabilities of flow cytometry. Here, we exploit the power of genetic engineering to barcode individual cells with genes encoding fluorescent proteins. For genetic engineering, we utilize retroviral technology, which allows for the expression of ectopic genetic information in a stable manner in mammalian cells. We have genetically barcoded both adherent and nonadherent cells with different fluorescent proteins. Multiplexing power was increased by combining both the number of distinct fluorescent proteins, and the fluorescence intensity in each channel. Moreover, retroviral expression has proven to be stable for at least a 6-month period, which is critical for applications such as biological screens. We have shown the applicability of fluorescent barcoded multiplexing to cell-based assays that rely themselves on genetic barcoding, or on classical staining protocols. Fluorescent genetic barcoding gives the cell an inherited characteristic that distinguishes it from its counterpart. Once cell lines are developed, no further manipulation or staining is required, decreasing time, nonspecific background associated with staining protocols, and cost. The increasing number of discovered and/or engineered fluorescent proteins with unique absorbance/emission spectra, combined with the growing number of detection devices and lasers, increases multiplexing versatility, making fluorescent genetic barcoding a powerful tool for flow cytometry-based analysis. © 2013 International Society for Advancement of Cytometry.
FlowSOM: Using self-organizing maps for visualization and interpretation of cytometry data.
Van Gassen, Sofie; Callebaut, Britt; Van Helden, Mary J; Lambrecht, Bart N; Demeester, Piet; Dhaene, Tom; Saeys, Yvan
2015-07-01
The number of markers measured in both flow and mass cytometry keeps increasing steadily. Although this provides a wealth of information, it becomes infeasible to analyze these datasets manually. When using 2D scatter plots, the number of possible plots increases exponentially with the number of markers and therefore, relevant information that is present in the data might be missed. In this article, we introduce a new visualization technique, called FlowSOM, which analyzes Flow or mass cytometry data using a Self-Organizing Map. Using a two-level clustering and star charts, our algorithm helps to obtain a clear overview of how all markers are behaving on all cells, and to detect subsets that might be missed otherwise. R code is available at https://github.com/SofieVG/FlowSOM and will be made available at Bioconductor. © 2015 International Society for Advancement of Cytometry.
Flow and image cytometers can provide useful quantitative fluorescence data. We have devised QA tests to be used on both a flow cytometer and a confocal microscope to assure that the data is accurate, reproducible and precise. Flow Cytometry: We have provided two simple perform...
Maslennikova, I L; Kuznetsova, M V; Toplak, N; Nekrasova, I V; Žgur Bertok, D; Starčič Erjavec, M
2018-05-07
The efficiency of the bacteriocin, colicin ColE7, bacterial conjugation-based "kill" - "anti-kill" antimicrobial system, was assessed using real-time PCR, flow cytometry and bioluminescence. The ColE7 antimicrobial system consists of the genetically modified Escherichia coli strain Nissle 1917 harbouring a conjugative plasmid (derivative of the F-plasmid) encoding the "kill" gene (ColE7 activity gene) and a chromosomally encoded "anti-kill" gene (ColE7 immunity gene). On the basis of traJ gene expression in the killer donor cells, our results showed that the efficiency of the here studied antimicrobial system against target E. coli was higher at 4 than at 24 h. Flow cytometry was used to indirectly estimate DNase activity of the antimicrobial system, as lysis of target E. coli cells in the conjugative mixture with the killer donor strain led to reduction in cell cytosol fluorescence. According to a lux assay, E. coli TG1 (pXen lux + Ap r ) with constitutive luminescence were killed already after 2 h of treatment. Target sensor E. coli C600 with DNA damage SOS-inducible luminescence showed significantly lower SOS induction 6 and 24 h following treatment with the killer donor strain. Our results thus showed that bioluminescent techniques are quick and suitable for estimation of the ColE7 bacterial conjugation-based antimicrobial system antibacterial activity. Bacterial antimicrobial resistance is worldwide rising and causing deaths of thousands of patients infected with multi-drug resistant bacterial strains. In addition, there is a lack of efficient alternative antimicrobial agents. The significance of our research is the use of a number of methods (real-time PCR, flow cytometry and bioluminescence-based technique) to assess the antibacterial activity of the bacteriocin, colicin ColE7, bacterial conjugation-based "kill" - "anti-kill" antimicrobial system. Bioluminescent techniques proved to be rapid and suitable for estimation of antibacterial activity of ColE7 bacterial conjugation-based antimicrobial system and possibly other related systems. © 2018 The Society for Applied Microbiology.
Davis, Bruce H; Wood, Brent; Oldaker, Teri; Barnett, David
2013-01-01
Flow cytometry and other technologies of cell-based fluorescence assays are as a matter of good laboratory practice required to validate all assays, which when in clinical practice may pass through regulatory review processes using criteria often defined with a soluble analyte in plasma or serum samples in mind. Recently the U.S. Food and Drug Administration (FDA) has entered into a public dialogue in the U.S. regarding their regulatory interest in laboratory developed tests (LDTs) or so-called "home brew" assays performed in clinical laboratories. The absence of well-defined guidelines for validation of cell-based assays using fluorescence detection has thus become a subject of concern for the International Council for Standardization of Haematology (ICSH) and International Clinical Cytometry Society (ICCS). Accordingly, a group of over 40 international experts in the areas of test development, test validation, and clinical practice of a variety of assay types using flow cytometry and/or morphologic image analysis were invited to develop a set of practical guidelines useful to in vitro diagnostic (IVD) innovators, clinical laboratories, regulatory scientists, and laboratory inspectors. The focus of the group was restricted to fluorescence reporter reagents, although some common principles are shared by immunohistochemistry or immunocytochemistry techniques and noted where appropriate. The work product of this two year effort is the content of this special issue of this journal, which is published as 5 separate articles, this being Validation of Cell-based Fluorescence Assays: Practice Guidelines from the ICSH and ICCS - Part I - Rationale and aims. © 2013 International Clinical Cytometry Society. © 2013 International Clinical Cytometry Society.
CyTOF workflow: differential discovery in high-throughput high-dimensional cytometry datasets
Nowicka, Malgorzata; Krieg, Carsten; Weber, Lukas M.; Hartmann, Felix J.; Guglietta, Silvia; Becher, Burkhard; Levesque, Mitchell P.; Robinson, Mark D.
2017-01-01
High dimensional mass and flow cytometry (HDCyto) experiments have become a method of choice for high throughput interrogation and characterization of cell populations.Here, we present an R-based pipeline for differential analyses of HDCyto data, largely based on Bioconductor packages. We computationally define cell populations using FlowSOM clustering, and facilitate an optional but reproducible strategy for manual merging of algorithm-generated clusters. Our workflow offers different analysis paths, including association of cell type abundance with a phenotype or changes in signaling markers within specific subpopulations, or differential analyses of aggregated signals. Importantly, the differential analyses we show are based on regression frameworks where the HDCyto data is the response; thus, we are able to model arbitrary experimental designs, such as those with batch effects, paired designs and so on. In particular, we apply generalized linear mixed models to analyses of cell population abundance or cell-population-specific analyses of signaling markers, allowing overdispersion in cell count or aggregated signals across samples to be appropriately modeled. To support the formal statistical analyses, we encourage exploratory data analysis at every step, including quality control (e.g. multi-dimensional scaling plots), reporting of clustering results (dimensionality reduction, heatmaps with dendrograms) and differential analyses (e.g. plots of aggregated signals). PMID:28663787
2009-09-01
euthanized, tumors harvested and portions processed for IHC, Western blot, flow cytometry , culture, and RNA analysis. If not enough tissue is available...temperature for 60 minutes. Samples were analyzed by flow cytometry using a BD FACScan. Data were analyzed with CellQuestPRO software. Evaluation of BrdUrd...were approved by the University of Washington Institutional Animal Care and Use Committee (IACUC). Flow cytometry . To measure tumor IGF-IR expression
Micro and Nano-mediated 3D Cardiac Tissue Engineering
2009-10-01
in both flow cytometry and Western Blot applications. The CD34 antigen is important in stem cell research due to its widespread use in identifying...for further characterization. We generated a pCD34 expressing CHO cell line (CHO-CD34) and analyzed pCD34 expression by flow cytometry (Figure 1A... flow cytometry using the 3G7 antibody and co-stained with an anti-CD31 antibody (AbD Serotec; FITC conjugated). CD31 (PECAM) is a pan endothelial
2011-01-01
normalized to parallel controls. Flow Cytometry and Confocal Microscopy Upon exposure to 10-ns EP, aliquots of the cellular suspension were added to a tube...Survival data was processed and plotted using GrapherH software (Golden Software, Golden, Colorado). Flow cytometry results were processed in C6 software...Accuri Cytometers, Inc., Ann Arbor, MI) and FCSExpress software (DeNovo Software, Los Angeles, CA). Final analysis and presentation of flow cytometry
Sensitivity of Breast Cancer Stem Cells to TRA-8 Anti-DR5 Monoclonal Antibody
2012-02-01
cytotoxicity and reduction in BrCSC marker expression. A. 2LMP cells were sorted using flow cytometry for CD44+/CD24-/ALDHhigh. Cells were pre...cells were sorted using flow cytometry for ALDH? cells and allowed to form primary tumorspheres for 3 days. After tumorspheres were mechanically...n =5 ) Day Fig. 5 Effect of ex vivo treatment of BrCSC enriched cells on tumorgenicity in NOD/SCID mice. 2LMP cells were sorted using flow cytometry
Canonical Wnt Signaling as a Specific Marker of Normal and Tumorigenic Mammary Stem Cells
2013-02-01
get enough sorted mammary cells for the transplantation experiments. We are currently working with our Flow Cytometry Core to sort Lin-/CD24+/CD49...activity our flow cytometry data suggests t here is a 2-fold increase in the number of FOG+ MEC’s in BATgal animals compared to contro ls which...this populat ion of cells is enriched for stem cell activity. Flow cytometry will determine the percentage of FOG+ cells within pre-neoplastic BATgai
CytoSPADE: high-performance analysis and visualization of high-dimensional cytometry data
Linderman, Michael D.; Simonds, Erin F.; Qiu, Peng; Bruggner, Robert V.; Sheode, Ketaki; Meng, Teresa H.; Plevritis, Sylvia K.; Nolan, Garry P.
2012-01-01
Motivation: Recent advances in flow cytometry enable simultaneous single-cell measurement of 30+ surface and intracellular proteins. CytoSPADE is a high-performance implementation of an interface for the Spanning-tree Progression Analysis of Density-normalized Events algorithm for tree-based analysis and visualization of this high-dimensional cytometry data. Availability: Source code and binaries are freely available at http://cytospade.org and via Bioconductor version 2.10 onwards for Linux, OSX and Windows. CytoSPADE is implemented in R, C++ and Java. Contact: michael.linderman@mssm.edu Supplementary Information: Additional documentation available at http://cytospade.org. PMID:22782546
Flow Cytometry Scientist | Center for Cancer Research
PROGRAM DESCRIPTION The Basic Science Program (BSP) pursues independent, multidisciplinary research in basic and applied molecular biology, immunology, retrovirology, cancer biology, and human genetics. Research efforts and support are an integral part of the Center for Cancer Research (CCR) at the Frederick National Laboratory for Cancer Research (FNLCR). KEY ROLES/RESPONSIBILITIES The Flow Cytometry Core (Flow Core) in the Cancer and Inflammation Program (CIP) is a service core which supports the research efforts of the CCR by providing expertise in the field of flow cytometry (using analyzers and sorters) with the goal of gaining a more thorough understanding of the biology of the immune system, cancer, and inflammation processes. The Flow Core provides service to 12-15 CIP laboratories and more than 22 non-CIP laboratories. Flow core staff provide technical advice on the experimental design of applications, which include immunological phenotyping, cell function assays, and cell cycle analysis. Work is performed per customer requirements, and no independent research is involved. The Flow Cytometry Scientist will be responsible for: Daily management of the Flow Cytometry Core, to include the supervision and guidance of technical staff members Monitor performance of and maintain high dimensional flow cytometer analyzers and cell sorters Operate high dimensional flow cytometer analyzers and cell sorters Provide scientific expertise to the user community and facilitate the development of cutting edge technologies Interact with Flow Core users and customers, and provide technical and scientific advice, and guidance regarding their experiments, including possible collaborations Train staff and scientific end users on the use of flow cytometry in their research, as well as teach them how to operate and troubleshoot the bench-top analyzer instruments Prepare and deliver lectures, as well as one-on-one training sessions, with customers/users Ensure that protocols are up-to-date, and appropriately adhered to Experience with sterile technique and tissue culture
Spaceflight Flow Cytometry: Design Challenges and Applications
NASA Technical Reports Server (NTRS)
Pappas, Dimitri; Kao, Shih-Hsin; Jeevarajan, Antony S.
2004-01-01
Future space exploration missions will require analytical technology capable of providing both autonomous medical care to the crew and investigative capabilities to researchers. While several promising candidate technologies exist for further development, flow cytometry is an attractive technology as it offers both crew health and a wide array of biochemistry and immunology assays. While flow cytometry has been widely used for cellular analysis in both clinical and research settings, the requirements for proper operation in spaceflight impose constraints on any instrument designs. The challenges of designing a spaceflight-ready flow cytometer are discussed, as well as some preliminary results using a prototype system.
Detection and capture of breast cancer cells with photoacoustic flow cytometry
NASA Astrophysics Data System (ADS)
Bhattacharyya, Kiran; Goldschmidt, Benjamin S.; Viator, John A.
2016-08-01
According to the Centers for Disease Control and Prevention, breast cancer is the most common cancer and the second leading cause of cancer related deaths among women. Metastasis-the presence of secondary tumors caused by the spread of cancer cells via the circulatory or lymphatic systems-significantly worsens the prognosis of any breast cancer patient. A technique is developed to detect circulating breast cancer cells in human blood using a photoacoustic flow cytometry method. A Q-switched laser is used to interrogate thousands of blood cells with one pulse as they flow through the beam path. Cells that are optically absorbing, either naturally or artificially, emit an ultrasound wave as a result of the photoacoustic (PA) effect. Breast cancer cells are targeted with chromophores through immunochemistry in order to enhance optical absorption. After which, the PA cytometry device is calibrated to demonstrate the ability to detect single cells. Cultured breast cancer cells are added to whole blood to reach a biologically relevant concentration of about 25 to 45 breast cancer cells per 1 mL of blood. An in vitro PA flow cytometer is used to detect and isolate these cells followed by capture with the use of a micromanipulator. This method can not only be used to determine the disease state of the patient and the response to therapy but also it can be used for genetic testing and in vitro drug trials since the circulating cell can be captured and studied.
Berget, Ellen; Helgeland, Lars; Liseth, Knut; Løkeland, Turid; Molven, Anders; Vintermyr, Olav Karsten
2014-01-01
Aims We aimed to evaluate the prognostic value of routine use of PCR amplification of immunoglobulin gene rearrangements in bone marrow (BM) staging in patients with follicular lymphoma (FL). Methods Clonal rearrangements were assessed by immunoglobulin heavy and light-chain gene rearrangement analysis in BM aspirates from 96 patients diagnosed with FL and related to morphological detection of BM involvement in biopsies. In 71 patients, results were also compared with concurrent flow cytometry analysis. Results BM involvement was detected by PCR in 34.4% (33/96) of patients. The presence of clonal rearrangements by PCR was associated with advanced clinical stage (I–III vs IV; p<0.001), high FL International Prognostic Index (FLIPI) score (0–1, 2 vs ≥3; p=0.003), and detection of BM involvement by morphology and flow cytometry analysis (p<0.001 for both). PCR-positive patients had a significantly poorer survival than PCR-negative patients (p=0.001, log-rank test). Thirteen patients positive by PCR but without morphologically detectable BM involvement, had significantly poorer survival than patients with negative morphology and negative PCR result (p=0.002). The poor survival associated with BM involvement by PCR was independent of the FLIPI score (p=0.007, Cox regression). BM involvement by morphology or flow cytometry did not show a significant impact on survival. Conclusions Our results showed that routine use of PCR-based clonality analysis significantly improved the prognostic impact of BM staging in patients with FL. BM involvement by PCR was also an independent adverse prognostic factor. PMID:25233852
A flow cytometric approach to the study of crustacean cellular immunity
Cardenas, W.; Jenkins, J.A.; Dankert, J.R.
2000-01-01
Responses of hemocytes from the crayfish Procambarus zonangulus to stimulation by fungal cell walls (Zymosan A) were measured by flow cytometry. Changes in hemocyte physical characteristics were assessed flow cytometrically using forward- and sidescatter light parameters, and viability was measured by two-color fluorescent staining with calcein-AM and ethidium homodimer 1. The main effects of zymosan A on crayfish hemocytes were reduction in cell size and viability compared to control mixtures (hemocytes in buffer only). Adding diethyldithiocarbamic acid, an inhibitor of phenoloxidase, to hemocyte to zymosan mixtures delayed the time course of cell size reduction and cell death compared to zymosan-positive controls. The inclusion of trypsin inhibitor in reaction mixtures further delayed the reduction in hemocyte size and cell death, thereby indicating that a proteolytic cascade, along with prophenoloxidase activation, played a key role in generating signal molecules which mediate these cellular responses. In addition to traditional methods such as microscopy and protein chemistry, flow cytometry can provide a simple, reproducible, and sensitve method for evaluating invertebrate hemocyte responses to immunological stimuli.
Yura, Hirofumi; Ishihara, Masayuki; Kanatani, Yasuhiro; Takase, Bonpei; Hattori, Hidemi; Suzuki, Shinya; Kawakami, Mitsuyuki; Matsui, Takemi
2006-04-01
Flow cytometric analysis of synthetic galactosyl polymers, asialofetuin and LDL derivatives labeled with FITC (Fluorescein Isothiocyanate) was carried out to determine the phenotypes of endocytic receptors, such as asialoglycoprotein (ASPG) and the LDL receptor, on various types of cells. When FITC-labeled galactosyl polystyrene (GalCPS), being a synthetic ligand of ASPG, was applied to rat hepatocytes and human cancer cells (Hep G2 and Chang Liver), surface fluorescence intensities varied according to receptor expression on the cells. The fluorescence intensity originates from the calcium-dependent binding of the FITC-labeled GalCPS. Although unaltered by pre-treatment with glucosyl polystyrene (GluCPS), fetuin and LDL, the fluorescence intensity was suppressed by pre-treatment with (non-labeled) GalCPS and asialofetuin. Flow cytometry allowed us to demonstrate that the calcium-dependent binding of FITC-labeled LDL (prepared from rabbits) upon the addition of 17alpha-ethinyl estradiol enhances LDL receptor expression, and the expression is suppressed upon the addition of a monoclonal antibody to the LDL receptor. The binding efficiency based on the combination of FITC-labeled ligands suggests a possible application for the classification of cell types and conditions corresponding to endocytic receptor expression without the need for immuno-active antibodies or radiolabeled substances. Furthermore, the synthetic glycoconjugate (GalCPS) is shown to be a sensitive and useful marker for classification based on cell phenotype using flow cytometry.
High speed flow cytometric separation of viable cells
Sasaki, D.T.; Van den Engh, G.J.; Buckie, A.M.
1995-11-14
Hematopoietic cell populations are separated to provide cell sets and subsets as viable cells with high purity and high yields, based on the number of original cells present in the mixture. High-speed flow cytometry is employed using light characteristics of the cells to separate the cells, where high flow speeds are used to reduce the sorting time.
High speed flow cytometric separation of viable cells
Sasaki, Dennis T.; Van den Engh, Gerrit J.; Buckie, Anne-Marie
1995-01-01
Hematopoietic cell populations are separated to provide cell sets and subsets as viable cells with high purity and high yields, based on the number of original cells present in the mixture. High-speed flow cytometry is employed using light characteristics of the cells to separate the cells, where high flow speeds are used to reduce the sorting time.
Rapid flow cytometry analysis of antimicrobial properties of nettle powder and cranberry powder
NASA Astrophysics Data System (ADS)
Hattuniemi, Maarit; Korhonen, Johanna; Jaakkola, Mari; Räty, Jarkko; Virtanen, Vesa
2010-11-01
Both nettle (Urtica dioica) and cranberry (Vaccinium oxycoccus) are widely known to have good influence on health. The aim of this study was to investigate antimicrobial properties of nettle powder and cranberry powder against Escherichia coli (E. coli) and monitor the growth of the bacteria by a rapid flow cytometry (FCM) method. For FCM measurements samples were stained with fluorescent dyes. The inhibitory effects of plant material on growth of E. coli were estimated by comparing the results of control sample (E. coli) to E. coli samples with plant material. FCM offers both a brilliant tool to investigate the kinetics of the growth of bacterium, since subsamples can be taken from the same liquid medium during the growing period and with fluorescent dyes a rapid method to investigate viability of the bacterium.
Poulcharidis, Dimitrios; Belfor, Kimberley
2017-01-01
Membrane-compound exchange is vital for cell-to-cell communication, yet quantification of this process is difficult. Here we present a method using flow cytometry in combination with bioorthogonal and fluorescent labelling techniques to quantify the amount of exchange of cholesterol and sialylated compounds between cells. We demonstrate that direct cell–cell contact is the likely mechanism of sterol-exchange and show that by manipulating the contact time between cells using complementary coiled-coil peptides results in an enhanced exchange rate of membrane components between cells. PMID:28970937
Avlasevich, Svetlana L; Khanal, Sumee; Singh, Priyanka; Torous, Dorothea K; Bemis, Jeffrey C; Dertinger, Stephen D
2018-04-01
The current report describes a newly devised method for automatically scoring the incidence of rat hepatocyte micronuclei (MNHEP) via flow cytometry, with concurrent assessments of hepatocyte proliferation-frequency of Ki-67-positive nuclei, and the proportion of polyploid nuclei. Proof-of-concept data are provided from experiments performed with 6-week old male Crl:CD(SD) rats exposed to diethylnitrosamine (DEN) or quinoline (QUIN) for 3 or 14 consecutive days. Non-perfused liver tissue was collected 4 days after cessation of treatment in the case of 3-day studies, or 1 day after last administration in the case of 14-day studies for processing and flow cytometric analysis. In addition to livers, blood samples were collected one day after final treatment for micronucleated reticulocyte (MN-RET) measurements. Dose-dependent increases in MNHEP, Ki-67-positive nuclei, and polyploidy were observed in 3- and 14-day DEN studies. Both treatment schedules resulted in elevated %MNHEP for QUIN-exposed rats, and while cell proliferation effects were subtle, appreciable increases to normalized liver weights were observed. Whereas DEN caused markedly higher %MNHEP when exposure was extended to two weeks, QUIN-induced MNHEP were slightly increased with protracted dosing. Parallel microscopy-based MNHEP frequencies were highly correlated with flow cytometry-based measurements (four study/aggregate R 2 = 0.80). No increases in MN-RET were seen in any of the four studies. Collectively, these results suggest liver micronuclei are amenable to an automated scoring technique that provides objective analyses and higher information content relative to conventional microscopy. Additional work is needed to expand the number and types of chemicals tested, identify the most advantageous treatment schedules, and test the transferability of the method. Environ. Mol. Mutagen. 59:176-187, 2018. © 2018 Wiley Periodicals, Inc. © 2018 Wiley Periodicals, Inc.
Absolute counting of neutrophils in whole blood using flow cytometry.
Brunck, Marion E G; Andersen, Stacey B; Timmins, Nicholas E; Osborne, Geoffrey W; Nielsen, Lars K
2014-12-01
Absolute neutrophil count (ANC) is used clinically to monitor physiological dysfunctions such as myelosuppression or infection. In the research laboratory, ANC is a valuable measure to monitor the evolution of a wide range of disease states in disease models. Flow cytometry (FCM) is a fast, widely used approach to confidently identify thousands of cells within minutes. FCM can be optimised for absolute counting using spiked-in beads or by measuring the sample volume analysed. Here we combine the 1A8 antibody, specific for the mouse granulocyte protein Ly6G, with flow cytometric counting in straightforward FCM assays for mouse ANC, easily implementable in the research laboratory. Volumetric and Trucount™ bead assays were optimized for mouse neutrophils, and ANC values obtained with these protocols were compared to ANC measured by a dual-platform assay using the Orphee Mythic 18 veterinary haematology analyser. The single platform assays were more precise with decreased intra-assay variability compared with ANC obtained using the dual protocol. Defining ANC based on Ly6G expression produces a 15% higher estimate than the dual protocol. Allowing for this difference in ANC definition, the flow cytometry counting assays using Ly6G can be used reliably in the research laboratory to quantify mouse ANC from a small volume of blood. We demonstrate the utility of the volumetric protocol in a time-course study of chemotherapy induced neutropenia using four drug regimens. © 2014 International Society for Advancement of Cytometry.
Positional dependence of particles in microfludic impedance cytometry.
Spencer, Daniel; Morgan, Hywel
2011-04-07
Single cell impedance cytometry is a label-free electrical analysis method that requires minimal sample preparation and has been used to count and discriminate cells on the basis of their impedance properties. This paper shows experimental and numerically simulated impedance signals for test particles (6 μm diameter polystyrene) flowing through a microfluidic channel. The variation of impedance signal with particle position is mapped using numerical simulation and these results match closely with experimental data. We demonstrate that for a nominal 40 μm × 40 μm channel, the impedance signal is independent of position over the majority of the channel area, but shows large experimentally verifiable variation at extreme positions. The parabolic flow profile in the channel ensures that most of the sample flows through the area of uniform signal. At high flow rates inertial focusing is observed; the particles flow in equal numbers through two equilibrium positions reducing the coefficient of variance (CV) in the impedance signals to negligible values.
An Active, Collaborative Approach to Learning Skills in Flow Cytometry
ERIC Educational Resources Information Center
Fuller, Kathryn; Linden, Matthew D.; Lee-Pullen, Tracey; Fragall, Clayton; Erber, Wendy N.; Röhrig, Kimberley J.
2016-01-01
Advances in science education research have the potential to improve the way students learn to perform scientific interpretations and understand science concepts. We developed active, collaborative activities to teach skills in manipulating flow cytometry data using FlowJo software. Undergraduate students were given compensated clinical flow…
Espinet, Blanca; Ferrer, Ana; Bellosillo, Beatriz; Nonell, Lara; Salar, Antonio; Fernández-Rodríguez, Concepción; Puigdecanet, Eulàlia; Gimeno, Javier; Garcia-Garcia, Mar; Vela, Maria Carmen; Luño, Elisa; Collado, Rosa; Navarro, José Tomás; de la Banda, Esmeralda; Abrisqueta, Pau; Arenillas, Leonor; Serrano, Cristina; Lloreta, Josep; Miñana, Belén; Cerutti, Andrea; Florensa, Lourdes; Orfao, Alberto; Sanz, Ferran; Solé, Francesc; Dominguez-Sola, David; Serrano, Sergio
2014-02-15
According to current diagnostic criteria, mantle cell lymphoma (MCL) encompasses the usual, aggressive variants and rare, nonnodal cases with monoclonal asymptomatic lymphocytosis, cyclin D1-positive (MALD1). We aimed to understand the biology behind this clinical heterogeneity and to identify markers for adequate identification of MALD1 cases. We compared 17 typical MCL cases with a homogeneous group of 13 untreated MALD1 cases (median follow-up, 71 months). We conducted gene expression profiling with functional analysis in five MCL and five MALD1. Results were validated in 12 MCL and 8 MALD1 additional cases by quantitative reverse transcription polymerase chain reaction (qRT-PCR) and in 24 MCL and 13 MALD1 cases by flow cytometry. Classification and regression trees strategy was used to generate an algorithm based on CD38 and CD200 expression by flow cytometry. We found 171 differentially expressed genes with enrichment of neoplastic behavior and cell proliferation signatures in MCL. Conversely, MALD1 was enriched in gene sets related to immune activation and inflammatory responses. CD38 and CD200 were differentially expressed between MCL and MALD1 and confirmed by flow cytometry (median CD38, 89% vs. 14%; median CD200, 0% vs. 24%, respectively). Assessment of both proteins allowed classifying 85% (11 of 13) of MALD1 cases whereas 15% remained unclassified. SOX11 expression by qRT-PCR was significantly different between MCL and MALD1 groups but did not improve the classification. We show for the first time that MALD1, in contrast to MCL, is characterized by immune activation and driven by inflammatory cues. Assessment of CD38/CD200 by flow cytometry is useful to distinguish most cases of MALD1 from MCL in the clinical setting. MALD1 should be identified and segregated from the current MCL category to avoid overdiagnosis and unnecessary treatment. ©2013 AACR
Espinet, Blanca; Ferrer, Ana; Bellosillo, Beatriz; Nonell, Lara; Salar, Antonio; Fernández-Rodríguez, Concepción; Puigdecanet, Eulàlia; Gimeno, Javier; Garcia-Garcia, Mar; Carmen Vela, Maria; Luño, Elisa; Collado, Rosa; Navarro, José Tomás; de la Banda, Esmeralda; Abrisqueta, Pau; Arenillas, Leonor; Serrano, Cristina; Lloreta, Josep; Miñana, Belén; Cerutti, Andrea; Florensa, Lourdes; Orfao, Alberto; Sanz, Ferran; Solé, Francesc; Dominguez-Sola, David; Serrano, Sergio
2015-01-01
Purpose According to current diagnostic criteria, mantle cell lymphoma (MCL) encompasses the usual, aggressive variants and rare, nonnodal cases with monoclonal asymptomatic lymphocytosis, cyclin D1–positive (MALD1). We aimed to understand the biology behind this clinical heterogeneity and to identify markers for adequate identification of MALD1 cases. Experimental Design We compared 17 typical MCL cases with a homogeneous group of 13 untreated MALD1 cases (median follow-up, 71 months). We conducted gene expression profiling with functional analysis in five MCL and five MALD1. Results were validated in 12 MCL and 8 MALD1 additional cases by quantitative reverse transcription polymerase chain reaction (qRT-PCR) and in 24 MCL and 13 MALD1 cases by flow cytometry. Classification and regression trees strategy was used to generate an algorithm based on CD38 and CD200 expression by flow cytometry. Results We found 171 differentially expressed genes with enrichment of neoplastic behavior and cell proliferation signatures in MCL. Conversely, MALD1 was enriched in gene sets related to immune activation and inflammatory responses. CD38 and CD200 were differentially expressed between MCL and MALD1 and confirmed by flow cytometry (median CD38, 89% vs. 14%; median CD200, 0% vs. 24%, respectively). Assessment of both proteins allowed classifying 85% (11 of 13) of MALD1 cases whereas 15% remained unclassified. SOX11 expression by qRT-PCR was significantly different between MCL and MALD1 groups but did not improve the classification. Conclusion We show for the first time that MALD1, in contrast to MCL, is characterized by immune activation and driven by inflammatory cues. Assessment of CD38/CD200 by flow cytometry is useful to distinguish most cases of MALD1 from MCL in the clinical setting. MALD1 should be identified and segregated from the current MCL category to avoid overdiagnosis and unnecessary treatment. PMID:24352646
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kovtun, Oleg; Ross, Emily J.; Tomlinson, Ian D.
Here we present the development and validation of a flow cytometry-based dopamine transporter (DAT) binding assay that uses antagonist-conjugated quantum dots (QDs). Our anticipation is that our QD-based assay is of immediate value to the high throughput screening of novel DAT modulators.
Multiplex polymerase chain reaction on FTA cards vs. flow cytometry for B-lymphocyte clonality.
Dictor, Michael; Skogvall, Ingela; Warenholt, Janina; Rambech, Eva
2007-01-01
Two-colour flow cytometry was compared with multiplex PCR with capillary electrophoresis for clonality determination in specific categories of B-cell lymphoma. FTA cards were evaluated for preserving DNA from node imprints and expediting molecular analysis. A single-tube multiplex PCR targeted IGH and lymphoma-specific translocations in DNA extracted from 180 frozen lymphoid tissues and DNA bound to FTA cards from 192 fresh tissues and 137 aspirates. PCR results were compared with flow cytometry in the extracted and aspirated samples. Overall, single-tube multiplex PCR sensitivity was equivalent in the sample groups (intergroup range 79%-91%). False negatives were associated with tumour origin in the follicle centre. Multiplex PCR and flow cytometry were equally sensitive and together detected 98% of B-cell lymphomas. Additional two-tube targeting of IGK suggested an overall molecular sensitivity >90%. False positive (pseudoclonal) single-tube multiplex PCR was associated with necrosis and sparse lymphocytes. Multiplex PCR using template DNA bound to an FTA card effectively detects B-lymphocyte clonality, obviates DNA extraction and refrigeration, and can be used without diminished sensitivity in fine needle aspirates or node imprints as a replacement for or complement to flow cytometry at any point in the diagnostic work-up.
Digital Analysis and Sorting of Fluorescence Lifetime by Flow Cytometry
Houston, Jessica P.; Naivar, Mark A.; Freyer, James P.
2010-01-01
Frequency-domain flow cytometry techniques are combined with modifications to the digital signal processing capabilities of the Open Reconfigurable Cytometric Acquisition System (ORCAS) to analyze fluorescence decay lifetimes and control sorting. Real-time fluorescence lifetime analysis is accomplished by rapidly digitizing correlated, radiofrequency modulated detector signals, implementing Fourier analysis programming with ORCAS’ digital signal processor (DSP) and converting the processed data into standard cytometric list mode data. To systematically test the capabilities of the ORCAS 50 MS/sec analog-to-digital converter (ADC) and our DSP programming, an error analysis was performed using simulated light scatter and fluorescence waveforms (0.5–25 ns simulated lifetime), pulse widths ranging from 2 to 15 µs, and modulation frequencies from 2.5 to 16.667 MHz. The standard deviations of digitally acquired lifetime values ranged from 0.112 to >2 ns, corresponding to errors in actual phase shifts from 0.0142° to 1.6°. The lowest coefficients of variation (<1%) were found for 10-MHz modulated waveforms having pulse widths of 6 µs and simulated lifetimes of 4 ns. Direct comparison of the digital analysis system to a previous analog phase-sensitive flow cytometer demonstrated similar precision and accuracy on measurements of a range of fluorescent microspheres, unstained cells and cells stained with three common fluorophores. Sorting based on fluorescence lifetime was accomplished by adding analog outputs to ORCAS and interfacing with a commercial cell sorter with a radiofrequency modulated solid-state laser. Two populations of fluorescent microspheres with overlapping fluorescence intensities but different lifetimes (2 and 7 ns) were separated to ~98% purity. Overall, the digital signal acquisition and processing methods we introduce present a simple yet robust approach to phase-sensitive measurements in flow cytometry. The ability to simply and inexpensively implement this system on a commercial flow sorter will both allow better dissemination of this technology and better exploit the traditionally underutilized parameter of fluorescence lifetime. PMID:20662090
Tips and tricks for flow cytometry-based analysis and counting of microparticles.
Poncelet, Philippe; Robert, Stéphane; Bailly, Nicolas; Garnache-Ottou, Francine; Bouriche, Tarik; Devalet, Bérangère; Segatchian, Jerard H; Saas, Philippe; Mullier, François
2015-10-01
Submicron-sized extra-cellular vesicles generated by budding from the external cell membranes, microparticles (MPs) are important actors in transfusion as well as in other medical specialties. After briefly positioning their role in the characterization of labile blood products, this technically oriented chapter aims to review practical points that need to be considered when trying to use flow cytometry for the analysis, characterization and absolute counting of MP subsets. Subjects of active discussions relative to instrumentation will include the choice of the trigger parameter, possible standardization approaches requiring instrument quality-control, origin and control of non-specific background and of coincidence artifacts, choice of the type of electronic signals, optimal sheath fluid and sample speed. Questions related to reagents will cover target antigens and receptors, multi-color reagents, negative controls, enumeration of MPs and limiting artifacts due to unexpected (micro-) coagulation of plasma samples. Newly detected problems are generating innovative solutions and flow cytometry will continue to remain the technology of choice for the analysis of MPs, in the domain of transfusion as well as in many diverse specialties. Copyright © 2015 Elsevier Ltd. All rights reserved.
Norman, Anders; Hansen, Lars Hestbjerg; Sørensen, Søren J
2006-02-28
Whole-cell biosensors have become popular tools for detection of ecotoxic compounds in environmental samples. We have developed an assay optimized for flow cytometry with detection of genotoxic compounds in mind. The assay features extended pre-incubation and a cell density of only 10(6)-10(7) cells/mL, and proved far more sensitive than a previously published assay using the same biosensor strain. By applying the SOS-green fluorescent protein (GFP) whole-cell biosensor directly to soil microcosms we were also able to evaluate both the applicability and sensitivity of a biosensor based on SOS-induction in whole soil samples. Soil microcosms were spiked with a dilution-series of crude broth extract from the mitomycin C-producing streptomycete Streptomyces caespitosus. Biosensors extracted from these microcosms after 1 day of incubation at 30 degrees C were easily distinguished from extracts of non-contaminated soil particles when using flow cytometry, and induction of the biosensor by mitomycin C was detectable at concentrations as low as 2.5 ng/g of soil.
Wu, Yang; Tapia, Phillip H.; Jarvik, Jonathan; Waggoner, Alan S.; Sklar, Larry A.
2014-01-01
We combined fluorogen activating protein (FAP) technology with high-throughput flow cytometry to detect real-time protein trafficking to and from the plasma membrane in living cells. The hybrid platform allows drug discovery for trafficking receptors, such as G-protein coupled receptors, receptor tyrosine kinases and ion channels, that were previously not suitable for high throughput screening by flow cytometry.. The system has been validated using the β2-adrenergic receptor (β2AR) system and extended to other GPCRs. When a chemical library containing ~1,200 off-patent drugs was screened against cells expressing FAP tagged β2AR, all known β2AR active ligands in the library were successfully identified, together with a few compounds that were later confirmed to regulate receptor internalization in a non-traditional manner. The unexpected discovery of new ligands by this approach indicates the potential of using this protocol for GPCR de-orphanization. In addition, screens of multiplexed targets promise improved efficiency with minor protocol modification. PMID:24510772
Flow cytometry in the post fluorescence era.
Nolan, Garry P
2011-12-01
While flow cytometry once enabled researchers to examine 10--15 cell surface parameters, new mass flow cytometry technology enables interrogation of up to 45 parameters on a single cell. This new technology has increased understanding of cell expression and how cells differentiate during hematopoiesis. Using this information, knowledge of leukemia cell biology has also increased. Other new technologies, such as SPADE analysis and single cell network profiling (SCNP), are enabling researchers to put different cancers into more biologically similar categories and have the potential to enable more personalized medicine. Copyright © 2011. Published by Elsevier Ltd.
2004-10-01
using flow cytometry after staining with CBA kit produced by BD-Pharmingen. The CBA kit can simultaneously test 5 inflammatory cytokines that include...or TLR4 transfected cells using flow cytometry . CHOK1 and CHOR1.1 cells were plated out in a 24-well dish and transfected 24 h later with either TLR2...with PE-labeled anti-hTLR2 antibody or PE-isotype control antibody (eBiosciences, CA), and cells were analyzed by flow cytometry . 39 The expression
2005-08-01
temperature in the dark, and then analyzed by flow cytometry within 3 hr of staining. 2.7. Caspase-3/-7 activity assay To measure cell-free caspase-3/-7...were treated with 50 mM of lactam 12 for the indicated hours. (A) Measurement of sub-G1 DNA content by flow cytometry analysis. The percentage of sub...Daniel for critical reading of the manuscript. We also appreciate the assistance of the Flow Cytometry Core at H. Lee Moffitt Cancer Center
Hector, R F; Braun, P C; Hart, J T; Kamarck, M E
1990-01-01
Flow cytometry was used to monitor chitin synthesis in regenerating protoplasts of the yeast Candida albicans. Comparisons of cells stained with Calcofluor White, a fluorochrome with known affinity for chitin, and cells incubated in the presence of N-[3H]-acetylglucosamine, the precursor substrate for chitin, showed a linear relationship between fluorescence and incorporation of label over time. Changes in both the fluorescence and light scatter of regenerating protoplasts treated with inhibitors of fungal chitin synthase were also quantitated by flow cytometry.
Gonsalves, Wilson I.; Rajkumar, S. Vincent; Dispenzieri, Angela; Dingli, David; Timm, Michael M.; Morice, William G.; Lacy, Martha Q.; Buadi, Francis K.; Go, Ronald S.; Leung, Nelson; Kapoor, Prashant; Hayman, Suzanne R.; Lust, John A.; Russell, Stephen J.; Zeldenrust, Steven R.; Hwa, Lisa; Kourelis, Taxiarchis V.; Kyle, Robert A.; Gertz, Morie A.; Kumar, Shaji K.
2017-01-01
The presence of high numbers of circulating clonal plasma cells (cPCs) in patients with smoldering multiple myeloma (SMM), detected by a slide-based immunofluorescence assay, has been associated with a shorter time to progression (TTP) to multiple myeloma (MM). The significance of quantifying cPCs via multiparameter flow cytometry, a much more readily available diagnostic modality, in patients with SMM has not been evaluated. This study evaluated 100 patients with a known or new diagnosis of SMM who were seen at the Mayo Clinic, Rochester from January 2008 until December 2013. Patients with ≥ 150 cPCs (N = 9) were considered to have high number of cPCs based on the 97% specificity and 78% PPV of progression to MM within 2 years of cPC assessment. The median TTP of patients with ≥ 150 cPCs was 9 months compared to not reached for patients with < 150 cPCs (P < 0.001). Thus, quantification of cPCs via multiparametric flow cytometry identifies patients with SMM at very high risk of progression to MM within 2 years and warrants confirmation in larger studies. In the future, this may allow reclassification of such patients as having MM requiring therapy prior to them enduring end-organ damage. PMID:27457702
Cao, Ruofan; Naivar, Mark A; Wilder, Mark; Houston, Jessica P
2014-01-01
Fluorescence lifetime measurements provide information about the fluorescence relaxation, or intensity decay, of organic fluorophores, fluorescent proteins, and other inorganic molecules that fluoresce. The fluorescence lifetime is emerging in flow cytometry and is helpful in a variety of multiparametric, single cell measurements because it is not impacted by nonlinearity that can occur with fluorescence intensity measurements. Yet time-resolved cytometry systems rely on major hardware modifications making the methodology difficult to reproduce. The motivation of this work is, by taking advantage of the dynamic nature of flow cytometry sample detection and applying digital signal processing methods, to measure fluorescence lifetimes using an unmodified flow cytometer. We collect a new lifetime-dependent parameter, referred to herein as the fluorescence-pulse-delay (FPD), and prove it is a valid representation of the average fluorescence lifetime. To verify we generated cytometric pulses in simulation, with light emitting diode (LED) pulsation, and with true fluorescence measurements of cells and microspheres. Each pulse is digitized and used in algorithms to extract an average fluorescence lifetime inherent in the signal. A range of fluorescence lifetimes is measurable with this approach including standard organic fluorophore lifetimes (∼1 to 22 ns) as well as small, simulated shifts (0.1 ns) under standard conditions (reported herein). This contribution demonstrates how digital data acquisition and signal processing can reveal time-dependent information foreshadowing the exploitation of full waveform analysis for quantification of similar photo-physical events within single cells. © 2014 The Authors. Published by Wiley Periodicals, Inc. PMID:25274073
Identification of contact and respiratory sensitizers using flow cytometry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goutet, Michele; Pepin, Elsa; Langonne, Isabelle
2005-06-15
Identification of the chemicals responsible for respiratory and contact allergies in the industrial area is an important occupational safety issue. This study was conducted in mice to determine whether flow cytometry is an appropriate method to analyze and differentiate the specific immune responses to the respiratory sensitizer trimellitic anhydride (TMA) and to the contact sensitizer dinitrochlorobenzene (DNCB) used at concentrations with comparable immunogenic potential. Mice were exposed twice on the flanks (days 0, 5) to 10% TMA or 1% DNCB and challenged three times on the ears (days 10, 11, 12) with 2.5% TMA or 0.25% DNCB. Flow cytometry analysesmore » were conducted on draining lymph node cells harvested on days 13 and 18. Comparing TMA and DNCB immune responses on day 13, we found obvious differences that persisted for most of them on day 18. An increased proportion of IgE+ cells correlated to total serum IgE level and an enhancement of MHC II molecule expression were observed in the lymph node B lymphocytes from TMA-treated mice. The percentage of IL-4-producing CD4+ lymphocytes and the IL-4 receptor expression were clearly higher following TMA exposure. In contrast, higher proportions of IL-2-producing cells were detected in CD4+ and CD8+ cells from DNCB-treated mice. Both chemicals induced a significant increase in the percentage of IFN-{gamma}-producing cells among CD8+ lymphocytes but to a greater proportion following TMA treatment. In conclusion, this study encourages the use of flow cytometry to discriminate between contact and respiratory sensitizers by identifying divergent expression of immune response parameters.« less
Collins, Denis M; Gately, Kathy; Hughes, Clare; Edwards, Connla; Davies, Anthony; Madden, Stephen F; O'Byrne, Kenneth J; O'Donovan, Norma; Crown, John
2017-09-01
Trastuzumab is an anti-HER2 monoclonal antibody (mAb) therapy capable of antibody-dependent cell-mediated cytotoxicity (ADCC) and used in the treatment of HER2+ breast cancer. Through interactions with FcƴR+ immune cell subsets, trastuzumab functions as a passive immunotherapy. The EGFR/HER2-targeting tyrosine kinase inhibitor (TKI) lapatinib and the next generation TKIs afatinib and neratinib, can alter HER2 levels, potentially modulating the ADCC response to trastuzumab. Using LDH-release assays, we investigated the impact of antigen modulation, assay duration and peripheral blood mononuclear cell (PBMC) activity on trastuzumab-mediated ADCC in breast cancer models of maximal (SKBR3) and minimal (MCF-7) target antigen expression to determine if modulating the ADCC response to trastuzumab using TKIs may be a viable approach for enhancing tumor immune reactivity. HER2 levels were determined in lapatinib, afatinib and neratinib-treated SKBR3 and MCF-7 using high content analysis (HCA). Trastuzumab-mediated ADCC was assessed following treatment with TKIs utilising a colorimetric LDH release-based protocol at 4 and 12h timepoints. PBMC activity was assessed against non-MHC-restricted K562 cells. A flow cytometry-based method (CFSE/7-AAD) was also used to measure trastuzumab-mediated ADCC in medium-treated SKBR3 and MCF-7. HER2 antigen levels were significantly altered by the three TKIs in both cell line models. The TKIs significantly reduced LDH levels directly in SKBR3 cells but not MCF-7. Lapatinib and neratinib augment trastuzumab-related ADCC in SKBR3 but the effect was not consistent with antigen expression levels and was dependent on volunteer PBMC activity (vs. K562). A 12h assay timepoint produced more consistent results. Trastuzumab-mediated ADCC (PBMC:target cell ratio of 10:1) was measured at 7.6±4.7% (T12) by LDH assay and 19±3.2 % (T12) using the flow cytometry-based method in the antigen-low model MCF-7. In the presence of effector cells with high cytotoxic capacity, TKIs have the ability to augment the passive immunotherapeutic potential of trastuzumab in SKBR3, a model of HER2+ breast cancer. ADCC levels detected by LDH release assays are extremely low in MCF-7; the flow cytometry-based CFSE/7-AAD method is more sensitive and consistent for the determination of ADCC in HER2-low models. Copyright © 2017 Elsevier Inc. All rights reserved.
Roberts, D J; Spellman, R A; Sanok, K; Chen, H; Chan, M; Yurt, P; Thakur, A K; DeVito, G L; Murli, H; Stankowski, L F
2012-05-01
A flow cytometric procedure for determining mitotic index (MI) as part of the metaphase chromosome aberrations assay, developed and utilized routinely at Pfizer as part of their standard assay design, has been adopted successfully by Covance laboratories. This method, using antibodies against phosphorylated histone tails (H3PS10) and nucleic acid stain, has been evaluated by the two independent test sites and compared to manual scoring. Primary human lymphocytes were treated with cyclophosphamide, mitomycin C, benzo(a)pyrene, and etoposide at concentrations inducing dose-dependent cytotoxicity. Deming regression analysis indicates that the results generated via flow cytometry (FCM) were more consistent between sites than those generated via microscopy. Further analysis using the Bland-Altman modification of the Tukey mean difference method supports this finding, as the standard deviations (SDs) of differences in MI generated by FCM were less than half of those generated manually. Decreases in scoring variability owing to the objective nature of FCM, and the greater number of cells analyzed, make FCM a superior method for MI determination. In addition, the FCM method has proven to be transferable and easily integrated into standard genetic toxicology laboratory operations. Copyright © 2012 Wiley Periodicals, Inc.
Setting objective thresholds for rare event detection in flow cytometry
Richards, Adam J.; Staats, Janet; Enzor, Jennifer; McKinnon, Katherine; Frelinger, Jacob; Denny, Thomas N.; Weinhold, Kent J.; Chan, Cliburn
2014-01-01
The accurate identification of rare antigen-specific cytokine positive cells from peripheral blood mononuclear cells (PBMC) after antigenic stimulation in an intracellular staining (ICS) flow cytometry assay is challenging, as cytokine positive events may be fairly diffusely distributed and lack an obvious separation from the negative population. Traditionally, the approach by flow operators has been to manually set a positivity threshold to partition events into cytokine-positive and cytokine-negative. This approach suffers from subjectivity and inconsistency across different flow operators. The use of statistical clustering methods does not remove the need to find an objective threshold between between positive and negative events since consistent identification of rare event subsets is highly challenging for automated algorithms, especially when there is distributional overlap between the positive and negative events (“smear”). We present a new approach, based on the Fβ measure, that is similar to manual thresholding in providing a hard cutoff, but has the advantage of being determined objectively. The performance of this algorithm is compared with results obtained by expert visual gating. Several ICS data sets from the External Quality Assurance Program Oversight Laboratory (EQAPOL) proficiency program were used to make the comparisons. We first show that visually determined thresholds are difficult to reproduce and pose a problem when comparing results across operators or laboratories, as well as problems that occur with the use of commonly employed clustering algorithms. In contrast, a single parameterization for the Fβ method performs consistently across different centers, samples, and instruments because it optimizes the precision/recall tradeoff by using both negative and positive controls. PMID:24727143
Balaguer, Susana; Diaz, Laura; Gomes, Angela; Herrera, Guadalupe; O'Connor, José-Enrique; Urios, Amparo; Felipo, Vicente; Montoliu, Carmina
2017-05-01
Nitric oxide (NO) and its related reactive nitrogen species (RNS) and reactive oxygen species (ROS) are crucial in monocyte responses against pathogens and also in inflammatory conditions. Central to both processes is the generation of the strong oxidant peroxynitrite (ONOO) by a fast reaction between NO and superoxide anion. ONOO is a biochemical junction for ROS- and RNS cytotoxicity and causes protein nitrosylation. Circulating by-products of protein nitrosylation are early biomarkers of inflammation-based conditions, including minimal hepatic encephalopathy in cirrhotic patients (Montoliu et al., Am J Gastroenterol 2011; 106:1629-1637). In this context, we have designed a novel no-wash, no-lyse real-time flow cytometry assay to detect and follow-up the NO- and superoxide-driven generation of ONOO in peripheral blood monocytes. Whole blood samples were stained with CD45 and CD14 antibodies plus one of a series of fluorescent probes sensitive to RNS, ROS, or glutathione, namely 4-amino-5-methylamino-2',7'-difluorofluorescein diacetate, dihydrorhodamine 123, MitoSOX Red, dihydroethidium, and 5-chloromethylfluorescein diacetate. Samples were exposed sequentially to a NO donor and three different superoxide donors, and analyzed in real time by kinetic flow cytometry. Relevant kinetic descriptors, such as the rate of fluorescence change, were calculated from the kinetic plot. The generation of ONOO, which consumes both NO and superoxide, led to a decrease in the intensity of the cellular fluorescence of the probes sensitive to these molecules. This is a fast and simple assay that may be used to monitor the intracellular generation of ONOO in physiological, pathological, and pharmacological contexts. © 2015 International Clinical Cytometry Society. © 2015 International Clinical Cytometry Society.
Kang, Dukjin; Oh, Sunok; Ahn, Sung-Min; Lee, Bong-Hee; Moon, Myeong Hee
2008-08-01
Exosomes, small membrane vesicles secreted by a multitude of cell types, are involved in a wide range of physiological roles such as intercellular communication, membrane exchange between cells, and degradation as an alternative to lysosomes. Because of the small size of exosomes (30-100 nm) and the limitations of common separation procedures including ultracentrifugation and flow cytometry, size-based fractionation of exosomes has been challenging. In this study, we used flow field-flow fractionation (FlFFF) to fractionate exosomes according to differences in hydrodynamic diameter. The exosome fractions collected from FlFFF runs were examined by transmission electron microscopy (TEM) to morphologically confirm their identification as exosomes. Exosomal lysates of each fraction were digested and analyzed using nanoflow LC-ESI-MS-MS for protein identification. FIFFF, coupled with mass spectrometry, allows nanoscale size-based fractionation of exosomes and is more applicable to primary cells and stem cells since it requires much less starting material than conventional gel-based separation, in-gel digestion and the MS-MS method.
Rice, G C; Bump, E A; Shrieve, D C; Lee, W; Kovacs, M
1986-12-01
An assay using a bimane derivative has been developed to detect free glutathione (GSH) in individual viable cells by flow cytometry. Monochlorobimane [syn-(ClCH2CH3)-1,5-diazabicycla[3.30]acta-3,6-diene-2,8-dio ne], itself nonfluorescent, reacts with GSH to form a highly fluorescent derivative. High pressure liquid chromatography analysis showed that, using specific staining conditions, the only low molecular weight fluorescent derivative formed in Chinese hamster ovary cells was that formed with GSH. Very little reaction with protein sulfhydryls was observed. Rates of GSH depletion in Chinese hamster ovary cells exposed to diethylmaleate were essentially the same, whether measured by relative fluorescence intensity, by flow cytometry or by enzymatic assay on cellular extracts. This method was shown to be useful for measurement of GSH resynthesis, uptake, and depletion by prolonged hypoxia and misonidazole treatment. Since measurements are made on individual cells, cell-to-cell variation and populational heterogeneity in GSH content are revealed by flow cytometry. Although under most conditions in vitro GSH content is relatively homogeneous, under certain circumstances, such as release from hypoxia, heterogeneity in populational GSH levels was observed. The significance of this heterogeneity is discussed in regard to the induction of gene amplification and drug resistance by transient hypoxia. Numerous subclones of Chinese hamster ovary cells selected by growth in Adriamycin or methotrexate-containing medium express elevated levels of GSH per cell. The method was extended to quantitate the GSH content of cells excised from EMT-6/SF mouse tumors that had been treated in vivo with L-buthionine-S-R-sulfoximine, an inhibitor of GSH synthesis. The bivariate analysis (forward angle light scatter versus monochlorobimane fluorescence) of cells derived from these tumors gave excellent resolution of normal and tumor cells and demonstrated extensive heterogeneity in the tumor cell population with respect to GSH content per cell.
Magnetic fingerprints of rolling cells for quantitative flow cytometry in whole blood
NASA Astrophysics Data System (ADS)
Reisbeck, Mathias; Helou, Michael Johannes; Richter, Lukas; Kappes, Barbara; Friedrich, Oliver; Hayden, Oliver
2016-09-01
Over the past 50 years, flow cytometry has had a profound impact on preclinical and clinical applications requiring single cell function information for counting, sub-typing and quantification of epitope expression. At the same time, the workflow complexity and high costs of such optical systems still limit flow cytometry applications to specialized laboratories. Here, we present a quantitative magnetic flow cytometer that incorporates in situ magnetophoretic cell focusing for highly accurate and reproducible rolling of the cellular targets over giant magnetoresistance sensing elements. Time-of-flight analysis is used to unveil quantitative single cell information contained in its magnetic fingerprint. Furthermore, we used erythrocytes as a biological model to validate our methodology with respect to precise analysis of the hydrodynamic cell diameter, quantification of binding capacity of immunomagnetic labels, and discrimination of cell morphology. The extracted time-of-flight information should enable point-of-care quantitative flow cytometry in whole blood for clinical applications, such as immunology and primary hemostasis.
NASA Astrophysics Data System (ADS)
Liu, Sijia; Sa, Ruhan; Maguire, Orla; Minderman, Hans; Chaudhary, Vipin
2015-03-01
Cytogenetic abnormalities are important diagnostic and prognostic criteria for acute myeloid leukemia (AML). A flow cytometry-based imaging approach for FISH in suspension (FISH-IS) was established that enables the automated analysis of several log-magnitude higher number of cells compared to the microscopy-based approaches. The rotational positioning can occur leading to discordance between spot count. As a solution of counting error from overlapping spots, in this study, a Gaussian Mixture Model based classification method is proposed. The Akaike information criterion (AIC) and Bayesian information criterion (BIC) of GMM are used as global image features of this classification method. Via Random Forest classifier, the result shows that the proposed method is able to detect closely overlapping spots which cannot be separated by existing image segmentation based spot detection methods. The experiment results show that by the proposed method we can obtain a significant improvement in spot counting accuracy.
Nagy, Peter; Szabó, Ágnes; Váradi, Tímea; Kovács, Tamás; Batta, Gyula; Szöllősi, János
2016-04-01
Fluorescence or Förster resonance energy transfer (FRET) remains one of the most widely used methods for assessing protein clustering and conformation. Although it is a method with solid physical foundations, many applications of FRET fall short of providing quantitative results due to inappropriate calibration and controls. This shortcoming is especially valid for microscopy where currently available tools have limited or no capability at all to display parameter distributions or to perform gating. Since users of multiparameter flow cytometry usually apply these tools, the absence of these features in applications developed for microscopic FRET analysis is a significant limitation. Therefore, we developed a graphical user interface-controlled Matlab application for the evaluation of ratiometric, intensity-based microscopic FRET measurements. The program can calculate all the necessary overspill and spectroscopic correction factors and the FRET efficiency and it displays the results on histograms and dot plots. Gating on plots and mask images can be used to limit the calculation to certain parts of the image. It is an important feature of the program that the calculated parameters can be determined by regression methods, maximum likelihood estimation (MLE) and from summed intensities in addition to pixel-by-pixel evaluation. The confidence interval of calculated parameters can be estimated using parameter simulations if the approximate average number of detected photons is known. The program is not only user-friendly, but it provides rich output, it gives the user freedom to choose from different calculation modes and it gives insight into the reliability and distribution of the calculated parameters. © 2016 International Society for Advancement of Cytometry. © 2016 International Society for Advancement of Cytometry.
A rapid method for infectivity titration of Andes hantavirus using flow cytometry.
Barriga, Gonzalo P; Martínez-Valdebenito, Constanza; Galeno, Héctor; Ferrés, Marcela; Lozach, Pierre-Yves; Tischler, Nicole D
2013-11-01
The focus assay is currently the most commonly used technique for hantavirus titer determination. This method requires an incubation time of between 5 and 11 days to allow the appearance of foci after several rounds of viral infection. The following work presents a rapid Andes virus (ANDV) titration assay, based on viral nucleocapsid protein (N) detection in infected cells by flow cytometry. To this end, an anti-N monoclonal antibody was used that was developed and characterized previously. ANDV N could be detected as early as 6 h post-infection, while viral release was not observed until 24-48 h post-infection. Given that ANDV detection was performed during its first round of infection, a time reduction for titer determination was possible and provided results in only two days. The viral titer was calculated from the percentage of N positive cells and agreed with focus assay titers. Furthermore, the assay was applied to quantify the inhibition of ANDV cell entry by patient sera and by preventing endosome acidification. This novel hantavirus titration assay is a highly quantitative and sensitive tool that facilitates infectivity titration of virus stocks, rapid screening for antiviral drugs, and may be further used to detect and quantify infectious virus in human samples. Copyright © 2013 Elsevier B.V. All rights reserved.
Gaber, Rok; Majerle, Andreja; Jerala, Roman; Benčina, Mojca
2013-01-01
To effectively fight against the human immunodeficiency virus infection/acquired immunodeficiency syndrome (HIV/AIDS) epidemic, ongoing development of novel HIV protease inhibitors is required. Inexpensive high-throughput screening assays are needed to quickly scan large sets of chemicals for potential inhibitors. We have developed a Förster resonance energy transfer (FRET)-based, HIV protease-sensitive sensor using a combination of a fluorescent protein pair, namely mCerulean and mCitrine. Through extensive in vitro characterization, we show that the FRET-HIV sensor can be used in HIV protease screening assays. Furthermore, we have used the FRET-HIV sensor for intracellular quantitative detection of HIV protease activity in living cells, which more closely resembles an actual viral infection than an in vitro assay. We have developed a high-throughput method that employs a ratiometric flow cytometry for analyzing large populations of cells that express the FRET-HIV sensor. The method enables FRET measurement of single cells with high sensitivity and speed and should be used when subpopulation-specific intracellular activity of HIV protease needs to be estimated. In addition, we have used a confocal microscopy sensitized emission FRET technique to evaluate the usefulness of the FRET-HIV sensor for spatiotemporal detection of intracellular HIV protease activity. PMID:24287545
In vivo photoacoustic flow cytometry for early malaria diagnosis.
Cai, Chengzhong; Carey, Kai A; Nedosekin, Dmitry A; Menyaev, Yulian A; Sarimollaoglu, Mustafa; Galanzha, Ekaterina I; Stumhofer, Jason S; Zharov, Vladimir P
2016-06-01
In vivo photoacoustic (PA) flow cytometry (PAFC) has already demonstrated a great potential for the diagnosis of deadly diseases through ultrasensitive detection of rare disease-associated circulating markers in whole blood volume. Here, we demonstrate the first application of this powerful technique for early diagnosis of malaria through label-free detection of malaria parasite-produced hemozoin in infected red blood cells (iRBCs) as high-contrast PA agent. The existing malaria tests using blood smears can detect the disease at 0.001-0.1% of parasitemia. On the contrary, linear PAFC showed a potential for noninvasive malaria diagnosis at an extremely low level of parasitemia of 0.0000001%, which is ∼10(3) times better than the existing tests. Multicolor time-of-flight PAFC with high-pulse repetition rate lasers at wavelengths of 532, 671, and 820 nm demonstrated rapid spectral and spatial identification and quantitative enumeration of individual iRBCs. Integration of PAFC with fluorescence flow cytometry (FFC) provided real-time simultaneous detection of single iRBCs and parasites expressing green fluorescence proteins, respectively. A combination of linear and nonlinear nanobubble-based multicolor PAFC showed capability to real-time control therapy efficiency by counting of iRBCs before, during, and after treatment. Our results suggest that high-sensitivity, high-resolution ultrafast PAFC-FFC platform represents a powerful research tool to provide the insight on malaria progression through dynamic study of parasite-cell interactions directly in bloodstream, whereas portable hand-worn PAFC device could be broadly used in humans for early malaria diagnosis. © 2016 International Society for Advancement of Cytometry. © 2016 International Society for Advancement of Cytometry.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Universities Space Research Association; Chappell, Lori J.; Whalen, Mary K.
2010-12-15
We developed a mathematical method to analyze flow cytometry data to describe the kinetics of {gamma}H2AX and pATF2 phosphorylations ensuing various qualities of low dose radiation in normal human fibroblast cells. Previously reported flow cytometry kinetic results for these DSB repair phospho-proteins revealed that distributions of intensity were highly skewed, severely limiting the detection of differences in the very low dose range. Distributional analysis reveals significant differences between control and low dose samples when distributions are compared using the Kolmogorov-Smirnov test. Radiation quality differences are found in the distribution shapes and when a nonlinear model is used to relate dosemore » and time to the decay of the mean ratio of phosphoprotein intensities of irradiated samples to controls. We analyzed cell cycle phase and radiation quality dependent characteristic repair times and residual phospho-protein levels with these methods. Characteristic repair times for {gamma}H2AX were higher following Fe nuclei as compared to X-rays in G1 cells (4.5 {+-} 0.46 h vs 3.26 {+-} 0.76 h, respectively), and in S/G2 cells (5.51 {+-} 2.94 h vs 2.87 {+-} 0.45 h, respectively). The RBE in G1 cells for Fe nuclei relative to X-rays for {gamma}H2AX was 2.05 {+-} 0.61 and 5.02 {+-} 3.47, at 2 h and 24-h postirradiation, respectively. For pATF2, a saturation effect is observed with reduced expression at high doses, especially for Fe nuclei, with much slower characteristic repair times (>7 h) compared to X-rays. RBEs for pATF2 were 0.66 {+-} 0.13 and 1.66 {+-} 0.46 at 2 h and 24 h, respectively. Significant differences in {gamma}H2AX and pATF2 levels comparing irradiated samples to control were noted even at the lowest dose analyzed (0.05 Gy) using these methods of analysis. These results reveal that mathematical models can be applied to flow cytometry data to uncover important and subtle differences following exposure to various qualities of low dose radiation.« less
NASA Astrophysics Data System (ADS)
Pestana, Noah Benjamin
Accurate quantification of circulating cell populations is important in many areas of pre-clinical and clinical biomedical research, for example, in the study of cancer metastasis or the immune response following tissue and organ transplants. Normally this is done "ex-vivo" by drawing and purifying a small volume of blood and then analyzing it with flow cytometry, hemocytometry or microfludic devices, but the sensitivity of these techniques are poor and the process of handling samples has been shown to affect cell viability and behavior. More recently "in vivo flow cytometry" (IVFC) techniques have been developed where fluorescently-labeled cells flowing in a small blood vessel in the ear or retina are analyzed, but the sensitivity is generally poor due to the small sampling volume. To address this, our group recently developed a method known as "Diffuse Fluorescence Flow Cytometry" (DFFC) that allows detection and counting of rare circulating cells with diffuse photons, offering extremely high single cell counting sensitivity. In this thesis, an improved DFFC prototype was designed and validated. The chief improvements were three-fold, i) improved optical collection efficiency, ii) improved detection electronics, and iii) development of a method to mitigate motion artifacts during in vivo measurements. In combination, these improvements yielded an overall instrument detection sensitivity better than 1 cell/mL in vivo, which is the most sensitive IVFC system reported to date. Second, development and validation of a low-cost microfluidic device reader for analysis of ocular fluids is described. We demonstrate that this device has equivalent or better sensitivity and accuracy compared a fluorescence microscope, but at an order-of-magnitude reduced cost with simplified operation. Future improvements to both instruments are also discussed.
Measurement and Characterization of Apoptosis by Flow Cytometry.
Telford, William; Tamul, Karen; Bradford, Jolene
2016-07-01
Apoptosis is an important mechanism in cell biology, playing a critical regulatory role in virtually every organ system. It has been particularly well characterized in the immune system, with roles ranging from immature immune cell development and selection to down-regulation of the mature immune response. Apoptosis is also the primary mechanism of action of anti-cancer drugs. Flow cytometry has been the method of choice for analyzing apoptosis in suspension cells for more than 25 years. Numerous assays have been devised to measure both the earliest and latest steps in the apoptotic process, from the earliest signal-transduction events to the late morphological changes in cell shape and granularity, proteolysis, and chromatin condensation. These assays are particularly powerful when combined into multicolor assays determining several apoptotic characteristics simultaneously. The multiparametric nature of flow cytometry makes this technology particularly suited to measuring apoptosis. In this unit, we will describe the four main techniques for analyzing caspase activity in apoptotic cells, combined with annexin V and cell permeability analysis. These relatively simple multiparametric assays are powerful techniques for assessing cell death. © 2016 by John Wiley & Sons, Inc. Copyright © 2016 John Wiley & Sons, Inc.
Lee, Denise; Grigoriadis, George; Westerman, David
2015-12-01
Flow cytometry is the most accessible method for minimal residual disease (MRD) detection due to its availability in most haematological centres. Using a precise combination of different antibodies, immunophenotypic detection of MRD in acute leukaemia can be performed by identifying abnormal combinations or expressions of antigens on malignant cells at diagnosis, during and post treatment. These abnormal phenotypes, referred to as leukaemia-associated immunophenotypes (LAIPs) are either absent or expressed at low frequency in normal bone marrow (BM) cells and are used to monitor the behaviour and quantitate the amount of residual disease following treatment. In paediatric acute lymphoblastic leukaemia (ALL), the level of MRD by multiparametric flow cytometry (MPFC) during therapy is recognised as an important predictor of outcome. Although less extensively studied, adult ALL and adult and paediatric acute myeloid leukaemia (AML) have also demonstrated similar findings. The challenge now is incorporating this information for risk-stratification so that therapy can be tailored individually and ultimately improve outcome while also limiting treatment-related toxicity. In this review we will elaborate on the current and future role of MPFC in MRD in acute leukaemia while also addressing its limitations.
Johnson, Paul E; Deromedi, Anthony J; Lebaron, Philippe; Catala, Philippe; Cash, Jennifer
2006-12-01
Pathogenic microorganisms are known to cause widespread waterborne disease worldwide. There is an urgent need to develop a technique for the real-time detection of pathogens in environmental samples at low concentrations, <10 microorganisms/ml, in large sample volumes, > or =100 ml. A novel method, Fountain Flowtrade mark cytometry, for the rapid and sensitive detection of individual microorganisms in aqueous samples is presented. Each sample is first incubated with a fluorescent label and then passed as a stream in front of a laser, which excites the label. The fluorescence is detected with a CCD imager as the sample flows toward the imager along its optical axis. The feasibility of Fountain Flow cytometry (FFC) is demonstrated by the detection of Escherichia coli labeled with ChemChrome CV6 and SYBR Gold in buffer and natural river water. Detections of labeled E. coli were made in aqueous suspensions with an efficiency of 96% +/- 14% down to a concentration approximately 200 bacteria/ml. The feasibility of FFC is demonstrated by the detection of E. coli in buffer and natural river water. FFC should apply to the detection of a wide range of pathogenic microorganisms including amoebae.
Wang, Jia; Zhong, Mintao; Liu, Ben; Sha, Li; Lun, Yongzhi; Zhang, Wei; Li, Xingyun; Wang, Xiaoli; Cao, Jing; Ning, Anhong; Huang, Min
2015-01-25
The shiitake mushroom Lentinula edodes has health benefits and is used to treat various diseases due to its immunomodulatory and antineoplastic properties. In the present study, the Latcripin-13 domain, isolated from L. edodes, was expressed in Escherichia coli Rosetta-gami(DE3) in the form of inclusion bodies. The Latcripin-13 domain was purified by Ni-His affinity chromatography with high purity and refolded by urea gradient dialysis. The product showed biological activity in A549 cells, a human lung cancer cell line, by flow cytometry and the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl-tetrazolium bromide (MTT) method. The MTT assay and the flow cytometry results revealed that there was a great difference between the Latcripin-13 domain-treated group and the control group (p<0.05). Similarly, cell apoptosis observed by transmission electron microscopy (TEM) supported the flow cytometry results. This work demonstrated that the Latcripin-13 domain can induce apoptosis of A549 cells, which will bring new insights into the development of new antitumor drugs in the future. Copyright © 2014 Elsevier B.V. All rights reserved.
Fontanini, G.; Pingitore, R.; Bigini, D.; Vignati, S.; Pepe, S.; Ruggiero, A.; Macchiarini, P.
1992-01-01
Results generated by the immunohistochemical staining with PC10, a new monoclonal antibody recognizing PCNA (a nuclear protein associated with cell proliferation) in formalin-fixed and paraffin-embedded tissue were compared with those of Ki-67 labeling and DNA flow cytometry in 47 consecutive non-small cell lung cancer (NSCLC). PCNA reactivity was observed in all samples and confined to the nuclei of cancer cells. Its frequency ranged from 0 to 80% (37.7 +/- 23.6) and larger sized, early-staged and DNA aneuploid tumors expressed a significant higher number of PCNA-reactive cells. The PCNA and Ki-67 labeling rates were closely correlated (r = 0.383, P = 0.009). By flow cytometry, we observed a good correlation among PCNA labeling and S-phase fraction (r = 0.422, P = .0093) and G1 phase (r = 0.303, P = .051) of the cell cycle. Results indicate that PCNA labeling with PC10 is a simple method for assessing the proliferative activity in formalin-fixed, paraffin-embedded tissue of NSCLC and correlates well with Ki-67 labeling and S-phase fraction of the cell cycle. Images Figure 2 PMID:1361306
Barfod, I H; Barfod, N M
1980-01-01
A new method for the evaluation of cell production rates combining flow cytometry (FCM) and the stathmokinetic method using vincristine sulphate (VS) has been used for the analysis of three aneuploid ascites tumours at different stages of growth. Using this technique it was possible to estimate the well-known decrease in cell production rates of ageing ascites tumours. The percentage of normal host cells in the aneuploid tumours studied was easily determined by FCM prior to the calculation of the tumour cell-production rates. A correlation was found between the percentage of tumour cells in the S phase and the tumour cell-production rate. This correlation is probably explained by the gradual transfer of proliferating cells in S phase to resting G1 and G2 phases with increasing tumour age.
Detection of ASC Speck Formation by Flow Cytometry and Chemical Cross-linking.
Hoss, Florian; Rolfes, Verena; Davanso, Mariana R; Braga, Tarcio T; Franklin, Bernardo S
2018-01-01
Assembly of a relatively large protein aggregate or "speck" formed by the adaptor protein ASC is a common downstream step in the activation of most inflammasomes. This unique feature of ASC allows its visualization by several imaging techniques and constitutes a reliable and feasible readout for inflammasome activation in cells and tissues. We have previously described step-by-step protocols to generate immortalized cell lines stably expressing ASC fused to a fluorescent protein for measuring inflammasome activation by confocal microscopy, and immunofluorescence of endogenous ASC in primary cells. Here, we present two more methods to detect ASC speck formation: (1) Assessment of ASC speck formation by flow cytometry; and (2) Chemical cross-linking of ASC followed by immunoblotting. These methods allow for the discrimination of inflammasome-activated versus non-activated cells, the identification of lineage-specific inflammasome activation in complex cell mixtures, and sorting of inflammasome-activated cells for further analysis.
Xu, Xiao-yan; Nie, Xiao-cui; Ma, Hai-ying; Song, Guo-qing; Zhang, Xiao-tong; Jin, Yu-nan; Yu, Yan-qiu
2015-04-01
Flow cytometry method (FCM) is a generally accepted tool to analyze apoptosis. Although apoptosis assay kit was applied by many companies, the manufacturers were not consistent with whether using Trypsin with EDTA to collect the adherent cells. In another words, the influence of EDTA on apoptotic ratio is not clear. In this work, we compared the proportion of apoptotic cells with EDTA or EDTA-free Trypsin treatment by FCM. We concluded that Trypsin with or without EDTA has little influence on the proportion of apoptotic cells. In addition, we found that the ratio of necrosis and apoptosis was different in cells collected by scraping. WAVE2 protein was analyzed as a typical example for movement related protein. WAVE2 expression is elevated in the EDTA Trypsin treated group, compared with EDTA-free Trypsin treatment and scrapping group. © The Author(s) 2014.
Identifying Stem-like Cells Using Mitochondrial Membrane Potential | Center for Cancer Research
Therapies that are based on living cells promise to improve treatments for metastatic cancer and for many degenerative diseases. Lasting treatment of these maladies may require the durable persistence of cells. Long-term engraftment of cells – for months or years – and the generation of large numbers of progeny are characteristics of stem cells. Most approaches to isolate viable hematopoetic stem cells and therapeutically active T cells are based on immunophenotyping using highly multicolored flow cytometry. However, these methods do not directly measure the metabolic features of cells, which are known to be important in predicting cell fate.
Flow Cytometry Sorting to Separate Viable Giant Viruses from Amoeba Co-culture Supernatants
Khalil, Jacques Y. B.; Langlois, Thierry; Andreani, Julien; Sorraing, Jean-Marc; Raoult, Didier; Camoin, Laurence; La Scola, Bernard
2017-01-01
Flow cytometry has contributed to virology but has faced many drawbacks concerning detection limits, due to the small size of viral particles. Nonetheless, giant viruses changed many concepts in the world of viruses, as a result of their size and hence opened up the possibility of using flow cytometry to study them. Recently, we developed a high throughput isolation of viruses using flow cytometry and protozoa co-culture. Consequently, isolating a viral mixture in the same sample became more common. Nevertheless, when one virus multiplies faster than others in the mixture, it is impossible to obtain a pure culture of the minority population. Here, we describe a robust sorting system, which can separate viable giant virus mixtures from supernatants. We tested three flow cytometry sorters by sorting artificial mixtures. Purity control was assessed by electron microscopy and molecular biology. As proof of concept, we applied the sorting system to a co-culture supernatant taken from a sample containing a viral mixture that we couldn't separate using end point dilution. In addition to isolating the quick-growing Mimivirus, we sorted and re-cultured a new, slow-growing virus, which we named “Cedratvirus.” The sorting assay presented in this paper is a powerful and versatile tool for separating viral populations from amoeba co-cultures and adding value to the new field of flow virometry. PMID:28111619
Flow Cytometry Sorting to Separate Viable Giant Viruses from Amoeba Co-culture Supernatants.
Khalil, Jacques Y B; Langlois, Thierry; Andreani, Julien; Sorraing, Jean-Marc; Raoult, Didier; Camoin, Laurence; La Scola, Bernard
2016-01-01
Flow cytometry has contributed to virology but has faced many drawbacks concerning detection limits, due to the small size of viral particles. Nonetheless, giant viruses changed many concepts in the world of viruses, as a result of their size and hence opened up the possibility of using flow cytometry to study them. Recently, we developed a high throughput isolation of viruses using flow cytometry and protozoa co-culture. Consequently, isolating a viral mixture in the same sample became more common. Nevertheless, when one virus multiplies faster than others in the mixture, it is impossible to obtain a pure culture of the minority population. Here, we describe a robust sorting system, which can separate viable giant virus mixtures from supernatants. We tested three flow cytometry sorters by sorting artificial mixtures. Purity control was assessed by electron microscopy and molecular biology. As proof of concept, we applied the sorting system to a co-culture supernatant taken from a sample containing a viral mixture that we couldn't separate using end point dilution. In addition to isolating the quick-growing Mimivirus , we sorted and re-cultured a new, slow-growing virus, which we named "Cedratvirus." The sorting assay presented in this paper is a powerful and versatile tool for separating viral populations from amoeba co-cultures and adding value to the new field of flow virometry.
Besmer, Michael D; Epting, Jannis; Page, Rebecca M; Sigrist, Jürg A; Huggenberger, Peter; Hammes, Frederik
2016-12-07
Detailed measurements of physical, chemical and biological dynamics in groundwater are key to understanding the important processes in place and their influence on water quality - particularly when used for drinking water. Measuring temporal bacterial dynamics at high frequency is challenging due to the limitations in automation of sampling and detection of the conventional, cultivation-based microbial methods. In this study, fully automated online flow cytometry was applied in a groundwater system for the first time in order to monitor microbial dynamics in a groundwater extraction well. Measurements of bacterial concentrations every 15 minutes during 14 days revealed both aperiodic and periodic dynamics that could not be detected previously, resulting in total cell concentration (TCC) fluctuations between 120 and 280 cells μL -1 . The aperiodic dynamic was linked to river water contamination following precipitation events, while the (diurnal) periodic dynamic was attributed to changes in hydrological conditions as a consequence of intermittent groundwater extraction. Based on the high number of measurements, the two patterns could be disentangled and quantified separately. This study i) increases the understanding of system performance, ii) helps to optimize monitoring strategies, and iii) opens the possibility for more sophisticated (quantitative) microbial risk assessment of drinking water treatment systems.
Besmer, Michael D.; Epting, Jannis; Page, Rebecca M.; Sigrist, Jürg A.; Huggenberger, Peter; Hammes, Frederik
2016-01-01
Detailed measurements of physical, chemical and biological dynamics in groundwater are key to understanding the important processes in place and their influence on water quality – particularly when used for drinking water. Measuring temporal bacterial dynamics at high frequency is challenging due to the limitations in automation of sampling and detection of the conventional, cultivation-based microbial methods. In this study, fully automated online flow cytometry was applied in a groundwater system for the first time in order to monitor microbial dynamics in a groundwater extraction well. Measurements of bacterial concentrations every 15 minutes during 14 days revealed both aperiodic and periodic dynamics that could not be detected previously, resulting in total cell concentration (TCC) fluctuations between 120 and 280 cells μL−1. The aperiodic dynamic was linked to river water contamination following precipitation events, while the (diurnal) periodic dynamic was attributed to changes in hydrological conditions as a consequence of intermittent groundwater extraction. Based on the high number of measurements, the two patterns could be disentangled and quantified separately. This study i) increases the understanding of system performance, ii) helps to optimize monitoring strategies, and iii) opens the possibility for more sophisticated (quantitative) microbial risk assessment of drinking water treatment systems. PMID:27924920
Barnett, David; Louzao, Raaul; Gambell, Peter; De, Jitakshi; Oldaker, Teri; Hanson, Curtis A
2013-01-01
Flow cytometry and other technologies of cell-based fluorescence assays are as a matter of good laboratory practice required to validate all assays, which when in clinical practice may pass through regulatory review processes using criteria often defined with a soluble analyte in plasma or serum samples in mind. Recently the U.S. Food and Drug Administration (FDA) has entered into a public dialogue in the U.S. regarding their regulatory interest in laboratory developed tests (LDTs) or so-called home brew assays performed in clinical laboratories. The absence of well-defined guidelines for validation of cell-based assays using fluorescence detection has thus become a subject of concern for the International Council for Standardization of Haematology (ICSH) and International Clinical Cytometry Society (ICCS). Accordingly, a group of over 40 international experts in the areas of test development, test validation, and clinical practice of a variety of assay types using flow cytometry and/or morphologic image analysis were invited to develop a set of practical guidelines useful to in vitro diagnostic (IVD) innovators, clinical laboratories, regulatory scientists, and laboratory inspectors. The focus of the group was restricted to fluorescence reporter reagents, although some common principles are shared by immunohistochemistry or immunocytochemistry techniques and noted where appropriate. The work product of this two year effort is the content of this special issue of this journal, which is published as 5 separate articles, this being Validation of Cell-based Fluorescence Assays: Practice Guidelines from the ICSH and ICCS - Part IV - Postanalytic considerations. © 2013 International Clinical Cytometry Society.
NASA Astrophysics Data System (ADS)
Bocsi, Jozsef; Luther, Ed; Mittag, Anja; Jensen, Ingo; Sack, Ulrich; Lenz, Dominik; Trezl, Lajos; Varga, Viktor S.; Molnar, Beea; Tarnok, Attila
2004-06-01
Background: Slide based cytometry (SBC) is a technology for the rapid stoichiometric analysis of cells fixed to surfaces. Its applications are highly versatile and ranges from the clinics to high throughput drug discovery. SBC is realized in different instruments such as the Laser Scanning Cytometer (LSC) and Scanning Fluorescent Microscope (SFM) and the novel inverted microscope based iCyte image cytometer (Compucyte Corp.). Methods: Fluorochrome labeled specimens were immobilized on microscopic slides. They were placed on a conventional fluorescence microscope and analyzed by photomultiplayers or digital camera. Data comparable to flow cytometry were generated. In addition, each individual event could be visualized. Applications: The major advantage of instruments is the combination of two features: a) the minimal sample volume needed, and b) the connection of fluorescence data and morphological information. Rare cells were detected, frequency of apoptosis by myricetin formaldehyde and H2O2 mixtures was determined;. Conclusion: LSC, SFM and the novel iCyte have a wide spectrum of applicability in SBC and can be introduced as a standard technology for multiple settings. In addition, the iCyte and SFM instrument is suited for high throughput screening by automation and may be in future adapted to telepathology due to their high quality images. (This study was supported by the IZKF-Leipzig, Germany and T 034245 OTKA, Hungary)
O'Brien-Simpson, Neil M; Pantarat, Namfon; Attard, Troy J; Walsh, Katrina A; Reynolds, Eric C
2016-01-01
We describe a microbial flow cytometry method that quantifies within 3 hours antimicrobial peptide (AMP) activity, termed Minimum Membrane Disruptive Concentration (MDC). Increasing peptide concentration positively correlates with the extent of bacterial membrane disruption and the calculated MDC is equivalent to its MBC. The activity of AMPs representing three different membranolytic modes of action could be determined for a range of Gram positive and negative bacteria, including the ESKAPE pathogens, E. coli and MRSA. By using the MDC50 concentration of the parent AMP, the method provides high-throughput, quantitative screening of AMP analogues. A unique feature of the MDC assay is that it directly measures peptide/bacteria interactions and lysed cell numbers rather than bacteria survival as with MIC and MBC assays. With the threat of multi-drug resistant bacteria, this high-throughput MDC assay has the potential to aid in the development of novel antimicrobials that target bacteria with improved efficacy.
Klapperstück, Thomas; Glanz, Dagobert; Hanitsch, Stefan; Klapperstück, Manuela; Markwardt, Fritz; Wohlrab, Johannes
2013-07-01
Quantitative determinations of the cell membrane potential of lymphocytes (Wilson et al., J Cell Physiol 1985;125:72-81) and thymocytes (Krasznai et al., J Photochem Photobiol B 1995;28:93-99) using the anionic dye DiBAC4 (3) proved that dye depletion in the extracellular medium as a result of cellular uptake can be negligible over a wide range of cell densities. In contrast, most flow cytometric studies have not verified this condition but rather assumed it from the start. Consequently, the initially prepared extracellular dye concentration has usually been used for the calculation of the Nernst potential of the dye. In this study, however, external dye depletion could be observed in both large IGR-1 and small LCL-HO cells under experimental conditions, which have often been applied routinely in spectrofluorimetry and flow cytometry. The maximum cell density at which dye depletion could be virtually avoided was dependent on cell size and membrane potential and definitely needed to be taken into account to ensure reliable results. In addition, accepted calibration procedures based on the partition of sodium and potassium (Goldman-Hodgkin-Katz equation) or potassium alone (Nernst equation) were performed by flow cytometry on cell suspensions with an appropriately low cell density. The observed extensive lack of concordance between the correspondingly calculated membrane potential and the equilibrium potential of DiBAC4 (3) revealed that these methods require the additional measurement of cation parameters (membrane permeability and/or intracellular concentration). In contrast, due to the linear relation between fluorescence and low DiBAC4 (3) concentrations, the Nernst potential of the dye for totally depolarized cells can be reliably used for calibration with an essentially lower effort and expense. Copyright © 2013 International Society for Advancement of Cytometry.
de Carvalho Bittencourt, Marcelo; Kohler, Chantal; Henard, Sandrine; Rabaud, Christian; Béné, Marie C; Faure, Gilbert C
2013-01-01
Quality assessment in flow cytometry cannot obey the same rules as those applicable to the measurement of chemical analytes. However, regular follow-up of known patients may provide a robust in-house control of cell subsets evaluation. Sequential blood samples assessed for 32 HIV patients over several years and showing good stability were retrospectively assessed to establish coefficient of variations of the percentages of CD3+, CD4+, CD8+ cells, and CD4+ absolute counts (ACs). Mean relative standard variations for the whole cohort were of 0.04, 0.14, 0.08, and 0.18 for CD3%, CD4%, CD8%, and CD4 ACs, respectively. In-house follow-up of regularly checked compliant patients is a good alternative to traditional and costly repeatability and reproducibility studies for the validation of routine flow cytometry. © 2013 International Clinical Cytometry Society. Copyright © 2013 International Clinical Cytometry Society.
Dreyer, Beatriz; Morte, Asunción; Pérez-Gilabert, Manuela; Honrubia, Mario
2006-08-01
The aim of this study was to reassess the use of autofluorescence for evaluating AM colonization in mycorrhizal roots in the light of criticisms of this method that affirmed that only metabolically inactive arbuscules autofluoresce. It was also investigated whether other mycorrhizal structures, such as hyphae, vesicles and spores, could be detected by autofluorescence, and whether the autofluorescence pattern of AM fungal structures could be exploited methodologically, for example, in the detection and sorting of spores by flow cytometry. Mycorrhizal roots of the palm species Brahea armata, Chamaerops humilis, Phoenix canariensis and Phoenix dactylifera were sectioned and observed by means of fluorescence microscopy. In addition, fungal structures isolated from mycorrhizal roots of P. dactylifera were examined. The same root sections and isolated fungal structures were subjected to vital staining with nitro blue tetrazolium to determine their metabolic state (active or inactive). Moreover, spores of Glomus intraradices, and Glomus clarum were studied by epifluorescence and flow cytometry. Mycorrhizal whole roots of Medicago sativa were also assessed by autofluorescence detection. In contrast to previous reports, the results presented in this paper clearly demonstrate that all fungal structures, both intra- and extraradical, autofluoresced under blue light excitation, regardless of their state (dead or alive). Some arbuscules isolated from roots and mature spores showed further autofluorescence under green light excitation. The source of the autofluorescence was localized in the fungal cell wall. It was shown that AM spores can be detected by flow cytometry. The results support the use of autofluorescence for the evaluation of AM colonization, at least in palm species, and refute previous criticisms of the method.
Kerényi, Adrienne; Beke Debreceni, Ildikó; Oláh, Zsolt; Ilonczai, Péter; Bereczky, Zsuzsanna; Nagy, Béla; Muszbek, László; Kappelmayer, János
2017-09-01
Heparin-induced thrombocytopenia (HIT) is a severe side effect of heparin treatment caused by platelet activating IgG antibodies generated against the platelet factor 4 (PF4)-heparin complex. Thrombocytopenia and thrombosis are the leading clinical symptoms of HIT. The clinical pretest probability of HIT was evaluated by the 4T score system. Laboratory testing of HIT was performed by immunological detection of antibodies against PF4-heparin complex (EIA) and two functional assays. Heparin-dependent activation of donor platelets by patient plasma was detected by flow cytometry. Increased binding of Annexin-V to platelets and elevated number of platelet-derived microparticles (PMP) were the indicators of platelet activation. EIA for IgG isotype HIT antibodies was performed in 405 suspected HIT patients. Based on negative EIA results, HIT was excluded in 365 (90%) of cases. In 40 patients with positive EIA test result functional tests were performed. Platelet activating antibodies were detected in 17 cases by Annexin V binding. PMP count analysis provided nearly identical results. The probability of a positive flow cytometric assay result was higher in patients with elevated antibody titer. 71% of patients with positive EIA and functional assay had thrombosis. EIA is an important first line laboratory test in the diagnosis of HIT; however, HIT must be confirmed by a functional test. Annexin V binding and PMP assays using flow cytometry are functional HIT tests convenient in a clinical diagnostic laboratory. The positive results of functional assays may predict the onset of thrombosis. © 2016 International Clinical Cytometry Society. © 2016 International Clinical Cytometry Society.
Highly multiparametric analysis by mass cytometry.
Ornatsky, Olga; Bandura, Dmitry; Baranov, Vladimir; Nitz, Mark; Winnik, Mitchell A; Tanner, Scott
2010-09-30
This review paper describes a new technology, mass cytometry, that addresses applications typically run by flow cytometer analyzers, but extends the capability to highly multiparametric analysis. The detection technology is based on atomic mass spectrometry. It offers quantitation, specificity and dynamic range of mass spectrometry in a format that is familiar to flow cytometry practitioners. The mass cytometer does not require compensation, allowing the application of statistical techniques; this has been impossible given the constraints of fluorescence noise with traditional cytometry instruments. Instead of "colors" the mass cytometer "reads" the stable isotope tags attached to antibodies using metal-chelating labeling reagents. Because there are many available stable isotopes, and the mass spectrometer provides exquisite resolution between detection channels, many parameters can be measured as easily as one. For example, in a single tube the technique allows for the ready detection and characterization of the major cell subsets in blood or bone marrow. Here we describe mass cytometric immunophenotyping of human leukemia cell lines and leukemia patient samples, differential cell analysis of normal peripheral and umbilical cord blood; intracellular protein identification and metal-encoded bead arrays. Copyright © 2010 Elsevier B.V. All rights reserved.
The cytometric future: it ain't necessarily flow!
Shapiro, Howard M
2011-01-01
Initial approaches to cytometry for classifying and characterizing cells were based on microscopy; it was necessary to collect relatively high-resolution images of cells because only a few specific reagents usable for cell identification were available. Although flow cytometry, now the dominant cytometric technology, typically utilizes lenses similar to microscope lenses for light collection, improved, more quantitative reagents allow the necessary information to be acquired in the form of whole-cell measurements of the intensities of light transmission, scattering, and/or fluorescence.Much of the cost and complexity of both automated microscopes and flow cytometers arises from the necessity for them to measure one cell at a time. Recent developments in digital camera technology now offer an alternative in which one or more low-magnification, low-resolution images are made of a wide field containing many cells, using inexpensive light-emitting diodes (LEDs) for illumination. Minimalist widefield imaging cytometers can provide a smaller, less complex, and substantially less expensive alternative to flow cytometry, critical in systems intended for in resource-poor areas. Minimalism is, likewise, a good philosophy in developing instrumentation and methodology for both clinical and large-scale research use; it simplifies quality assurance and compliance with regulatory requirements, as well as reduces capital outlays, material costs, and personnel training requirements. Also, importantly, it yields "greener" technology.
2014-10-01
Bendall SC, Sung P, Nolan GP, Arvin AM. Single-cell mass cytometry analysis of human tonsil T cell remodeling by varicella zoster virus. Cell Rep...Perspectives on Flow Cytometry 2013, September 20, 2013, Mass Cytometry and Cell Cycle, Mexico City, Mexico (by Web Conference) Nolan: Nuclear
Recchia, Anna Grazia; Caruso, Nadia; Bossio, Sabrina; Pellicanò, Mariavaleria; De Stefano, Laura; Franzese, Stefania; Palummo, Angela; Abbadessa, Vincenzo; Lucia, Eugenio; Gentile, Massimo; Vigna, Ernesto; Caracciolo, Clementina; Agostino, Antolino; Galimberti, Sara; Levato, Luciano; Stagno, Fabio; Molica, Stefano; Martino, Bruno; Vigneri, Paolo; Di Raimondo, Francesco; Morabito, Fortunato
2015-01-01
Chronic Myeloid Leukemia (CML) is characterized by a balanced translocation juxtaposing the Abelson (ABL) and breakpoint cluster region (BCR) genes. The resulting BCR-ABL1 oncogene leads to increased proliferation and survival of leukemic cells. Successful treatment of CML has been accompanied by steady improvements in our capacity to accurately and sensitively monitor therapy response. Currently, measurement of BCR-ABL1 mRNA transcript levels by real-time quantitative PCR (RQ-PCR) defines critical response endpoints. An antibody-based technique for BCR-ABL1 protein recognition could be an attractive alternative to RQ-PCR. To date, there have been no studies evaluating whether flow-cytometry based assays could be of clinical utility in evaluating residual disease in CML patients. Here we describe a flow-cytometry assay that detects the presence of BCR-ABL1 fusion proteins in CML lysates to determine the applicability, reliability, and specificity of this method for both diagnosis and monitoring of CML patients for initial response to therapy. We show that: i) CML can be properly diagnosed at onset, (ii) follow-up assessments show detectable fusion protein (i.e. relative mean fluorescent intensity, rMFI%>1) when BCR-ABL1IS transcripts are between 1–10%, and (iii) rMFI% levels predict CCyR as defined by FISH analysis. Overall, the FCBA assay is a rapid technique, fully translatable to the routine management of CML patients. PMID:26111048
SURVIVAL OF SALMONELLA SPECIES IN RIVER WATER
The survival of four Salmonella strains in river water microcosms was monitored by culturing techniques, direct counts, whole-cell hybridization, scanning electron microscopy, and resuscitation techniques via the direct viable count method and flow cytometry. Plate counts of bact...
Józwa, Wojciech; Czaczyk, Katarzyna
2012-04-02
Flow cytometry constitutes an alternative for traditional methods of microorganisms identification and analysis, including methods requiring cultivation step. It enables the detection of pathogens and other microorganisms contaminants without the need to culture microbial cells meaning that the sample (water, waste or food e.g. milk, wine, beer) may be analysed directly. This leads to a significant reduction of time required for analysis allowing monitoring of production processes and immediate reaction in case of contamination or any disruption occurs. Apart from the analysis of raw materials or products on different stages of manufacturing process, the flow cytometry seems to constitute an ideal tool for the assessment of microbial contamination on the surface of technological lines. In the present work samples comprising smears from 3 different surfaces of technological lines from fruit and vegetable processing company from Greater Poland were analysed directly with flow cytometer. The measured parameters were forward and side scatter of laser light signals allowing the estimation of microbial cell contents in each sample. Flow cytometric analysis of the surface of food industry production lines enable the preliminary evaluation of microbial contamination within few minutes from the moment of sample arrival without the need of sample pretreatment. The presented method of fl ow cytometric initial evaluation of microbial state of food industry technological lines demonstrated its potential for developing a robust, routine method for the rapid and labor-saving detection of microbial contamination in food industry.
Flow cytometry microscopy and hyperspectral imaging of microcystis, cyanobacteria and algae
The detection of algae and cyanobacteria is an important step in assessing water quality. Studies were initiated using microscopy, flow cytometry and hyperspectral imaging with two fresh water species that could be grown in the laboratory: Microcystis Aeruginosa (cyanobacteria),...
NASA Astrophysics Data System (ADS)
Mok, Aaron T. Y.; Lee, Kelvin C. M.; Wong, Kenneth K. Y.; Tsia, Kevin K.
2018-02-01
Biophysical properties of cells could complement and correlate biochemical markers to characterize a multitude of cellular states. Changes in cell size, dry mass and subcellular morphology, for instance, are relevant to cell-cycle progression which is prevalently evaluated by DNA-targeted fluorescence measurements. Quantitative-phase microscopy (QPM) is among the effective biophysical phenotyping tools that can quantify cell sizes and sub-cellular dry mass density distribution of single cells at high spatial resolution. However, limited camera frame rate and thus imaging throughput makes QPM incompatible with high-throughput flow cytometry - a gold standard in multiparametric cell-based assay. Here we present a high-throughput approach for label-free analysis of cell cycle based on quantitative-phase time-stretch imaging flow cytometry at a throughput of > 10,000 cells/s. Our time-stretch QPM system enables sub-cellular resolution even at high speed, allowing us to extract a multitude (at least 24) of single-cell biophysical phenotypes (from both amplitude and phase images). Those phenotypes can be combined to track cell-cycle progression based on a t-distributed stochastic neighbor embedding (t-SNE) algorithm. Using multivariate analysis of variance (MANOVA) discriminant analysis, cell-cycle phases can also be predicted label-free with high accuracy at >90% in G1 and G2 phase, and >80% in S phase. We anticipate that high throughput label-free cell cycle characterization could open new approaches for large-scale single-cell analysis, bringing new mechanistic insights into complex biological processes including diseases pathogenesis.
Multi-parametric analysis of phagocyte antimicrobial responses using imaging flow cytometry.
Havixbeck, Jeffrey J; Wong, Michael E; More Bayona, Juan A; Barreda, Daniel R
2015-08-01
We feature a multi-parametric approach based on an imaging flow cytometry platform for examining phagocyte antimicrobial responses against the gram-negative bacterium Aeromonas veronii. This pathogen is known to induce strong inflammatory responses across a broad range of animal species, including humans. We examined the contribution of A. veronii to the induction of early phagocyte inflammatory processes in RAW 264.7 murine macrophages in vitro. We found that A. veronii, both in live or heat-killed forms, induced similar levels of macrophage activation based on NF-κB translocation. Although these macrophages maintained high levels of viability following heat-killed or live challenges with A. veronii, we identified inhibition of macrophage proliferation as early as 1h post in vitro challenge. The characterization of phagocytic responses showed a time-dependent increase in phagocytosis upon A. veronii challenge, which was paired with a robust induction of intracellular respiratory burst responses. Interestingly, despite the overall increase in the production of reactive oxygen species (ROS) among RAW 264.7 macrophages, we found a significant reduction in the production of ROS among the macrophage subset that had bound A. veronii. Phagocytic uptake of the pathogen further decreased ROS production levels, even beyond those of unstimulated controls. Overall, this multi-parametric imaging flow cytometry-based approach allowed for segregation of unique phagocyte sub-populations and examination of their downstream antimicrobial responses, and should contribute to improved understanding of phagocyte responses against Aeromonas and other pathogens. Copyright © 2015 Elsevier B.V. All rights reserved.
Wang, Meiyao; Misakian, Martin; He, Hua-Jun; Bajcsy, Peter; Abbasi, Fatima; Davis, Jeffrey M; Cole, Kenneth D; Turko, Illarion V; Wang, Lili
2014-01-01
In our previous study that characterized different human CD4+ lymphocyte preparations, it was found that both commercially available cryopreserved peripheral blood mononuclear cells (PBMC) and a commercially available lyophilized PBMC (Cyto-Trol™) preparation fulfilled a set of criteria for serving as biological calibrators for quantitative flow cytometry. However, the biomarker CD4 protein expression level measured for T helper cells from Cyto-Trol was about 16% lower than those for cryopreserved PBMC and fresh whole blood using flow cytometry and mass cytometry. A primary reason was hypothesized to be due to steric interference in anti- CD4 antibody binding to the smaller sized lyophilized control cells. Targeted multiple reaction monitoring (MRM) mass spectrometry (MS) is used to quantify the copy number of CD4 receptor protein per CD4+ lymphocyte. Scanning electron microscopy (SEM) is utilized to assist searching the underlying reasons for the observed difference in CD4 receptor copy number per cell determined by MRM MS and CD4 expression measured previously by flow cytometry. The copy number of CD4 receptor proteins on the surface of the CD4+ lymphocyte in cryopreserved PBMCs and in lyophilized control cells is determined to be (1.45 ± 0.09) × 10(5) and (0.85 ± 0.11) × 10(5), respectively, averaged over four signature peptides using MRM MS. In comparison with cryopreserved PBMCs, there are more variations in the CD4 copy number in lyophilized control cells determined based on each signature peptide. SEM images of CD4+ lymphocytes from lyophilized control cells are very different when compared to the CD4+ T cells from whole blood and cryopreserved PBMC. Because of the lyophilization process applied to Cyto-Trol control cells, a lower CD4 density value, defined as the copy number of CD4 receptors per CD4+ lymphocyte, averaged over three different production lots is most likely explained by the loss of the CD4 receptors on damaged and/or broken microvilli where CD4 receptors reside. Steric hindrance of antibody binding and the association of CD4 receptors with other biomolecules likely contribute significantly to the nearly 50% lower CD4 receptor density value for cryopreserved PBMC determined from flow cytometry compared to the value obtained from MRM MS.
flowAI: automatic and interactive anomaly discerning tools for flow cytometry data.
Monaco, Gianni; Chen, Hao; Poidinger, Michael; Chen, Jinmiao; de Magalhães, João Pedro; Larbi, Anis
2016-08-15
Flow cytometry (FCM) is widely used in both clinical and basic research to characterize cell phenotypes and functions. The latest FCM instruments analyze up to 20 markers of individual cells, producing high-dimensional data. This requires the use of the latest clustering and dimensionality reduction techniques to automatically segregate cell sub-populations in an unbiased manner. However, automated analyses may lead to false discoveries due to inter-sample differences in quality and properties. We present an R package, flowAI, containing two methods to clean FCM files from unwanted events: (i) an automatic method that adopts algorithms for the detection of anomalies and (ii) an interactive method with a graphical user interface implemented into an R shiny application. The general approach behind the two methods consists of three key steps to check and remove suspected anomalies that derive from (i) abrupt changes in the flow rate, (ii) instability of signal acquisition and (iii) outliers in the lower limit and margin events in the upper limit of the dynamic range. For each file analyzed our software generates a summary of the quality assessment from the aforementioned steps. The software presented is an intuitive solution seeking to improve the results not only of manual but also and in particular of automatic analysis on FCM data. R source code available through Bioconductor: http://bioconductor.org/packages/flowAI/ CONTACTS: mongianni1@gmail.com or Anis_Larbi@immunol.a-star.edu.sg Supplementary data are available at Bioinformatics online. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
ggCyto: Next Generation Open-Source Visualization Software for Cytometry.
Van, Phu; Jiang, Wenxin; Gottardo, Raphael; Finak, Greg
2018-06-01
Open source software for computational cytometry has gained in popularity over the past few years. Efforts such as FlowCAP, the Lyoplate and Euroflow projects have highlighted the importance of efforts to standardize both experimental and computational aspects of cytometry data analysis. The R/BioConductor platform hosts the largest collection of open source cytometry software covering all aspects of data analysis and providing infrastructure to represent and analyze cytometry data with all relevant experimental, gating, and cell population annotations enabling fully reproducible data analysis. Data visualization frameworks to support this infrastructure have lagged behind. ggCyto is a new open-source BioConductor software package for cytometry data visualization built on ggplot2 that enables ggplot-like functionality with the core BioConductor flow cytometry data structures. Amongst its features are the ability to transform data and axes on-the-fly using cytometry-specific transformations, plot faceting by experimental meta-data variables, and partial matching of channel, marker and cell populations names to the contents of the BioConductor cytometry data structures. We demonstrate the salient features of the package using publicly available cytometry data with complete reproducible examples in a supplementary material vignette. https://bioconductor.org/packages/devel/bioc/html/ggcyto.html. gfinak@fredhutch.org. Supplementary data are available at Bioinformatics online and at http://rglab.org/ggcyto/.
Optofluidic Fluorescent Imaging Cytometry on a Cell Phone
Zhu, Hongying; Mavandadi, Sam; Coskun, Ahmet F.; Yaglidere, Oguzhan; Ozcan, Aydogan
2012-01-01
Fluorescent microscopy and flow cytometry are widely used tools in biomedical sciences. Cost-effective translation of these technologies to remote and resource-limited environments could create new opportunities especially for telemedicine applications. Toward this direction, here we demonstrate the integration of imaging cytometry and fluorescent microscopy on a cell phone using a compact, lightweight, and cost-effective optofluidic attachment. In this cell-phone-based optofluidic imaging cytometry platform, fluorescently labeled particles or cells of interest are continuously delivered to our imaging volume through a disposable microfluidic channel that is positioned above the existing camera unit of the cell phone. The same microfluidic device also acts as a multilayered optofluidic waveguide and efficiently guides our excitation light, which is butt-coupled from the side facets of our microfluidic channel using inexpensive light-emitting diodes. Since the excitation of the sample volume occurs through guided waves that propagate perpendicular to the detection path, our cell-phone camera can record fluorescent movies of the specimens as they are flowing through the microchannel. The digital frames of these fluorescent movies are then rapidly processed to quantify the count and the density of the labeled particles/cells within the target solution of interest. We tested the performance of our cell-phone-based imaging cytometer by measuring the density of white blood cells in human blood samples, which provided a decent match to a commercially available hematology analyzer. We further characterized the imaging quality of the same platform to demonstrate a spatial resolution of ~2 μm. This cell-phone-enabled optofluidic imaging flow cytometer could especially be useful for rapid and sensitive imaging of bodily fluids for conducting various cell counts (e.g., toward monitoring of HIV+ patients) or rare cell analysis as well as for screening of water quality in remote and resource-poor settings. PMID:21774454
Optofluidic fluorescent imaging cytometry on a cell phone.
Zhu, Hongying; Mavandadi, Sam; Coskun, Ahmet F; Yaglidere, Oguzhan; Ozcan, Aydogan
2011-09-01
Fluorescent microscopy and flow cytometry are widely used tools in biomedical sciences. Cost-effective translation of these technologies to remote and resource-limited environments could create new opportunities especially for telemedicine applications. Toward this direction, here we demonstrate the integration of imaging cytometry and fluorescent microscopy on a cell phone using a compact, lightweight, and cost-effective optofluidic attachment. In this cell-phone-based optofluidic imaging cytometry platform, fluorescently labeled particles or cells of interest are continuously delivered to our imaging volume through a disposable microfluidic channel that is positioned above the existing camera unit of the cell phone. The same microfluidic device also acts as a multilayered optofluidic waveguide and efficiently guides our excitation light, which is butt-coupled from the side facets of our microfluidic channel using inexpensive light-emitting diodes. Since the excitation of the sample volume occurs through guided waves that propagate perpendicular to the detection path, our cell-phone camera can record fluorescent movies of the specimens as they are flowing through the microchannel. The digital frames of these fluorescent movies are then rapidly processed to quantify the count and the density of the labeled particles/cells within the target solution of interest. We tested the performance of our cell-phone-based imaging cytometer by measuring the density of white blood cells in human blood samples, which provided a decent match to a commercially available hematology analyzer. We further characterized the imaging quality of the same platform to demonstrate a spatial resolution of ~2 μm. This cell-phone-enabled optofluidic imaging flow cytometer could especially be useful for rapid and sensitive imaging of bodily fluids for conducting various cell counts (e.g., toward monitoring of HIV+ patients) or rare cell analysis as well as for screening of water quality in remote and resource-poor settings.
Flow Cytometry, Microscopy and Hyperspectral Imaging of microcystis, Cyanobacteria, and Algae- SETAC
The detection of cyanobacteria algae, and picoplankton, in water is an important step in assessing water quality. Studies were initiated using fluorescence microscopy, flow cytometry and hyperspectral imaging with two fresh water species that were cultured in the laboratory:Micr...
Arakaki, Atsushi; Shibusawa, Mie; Hosokawa, Masahito; Matsunaga, Tadashi
2010-03-01
Magnetotactic bacteria comprise a phylogenetically diverse group that is capable of synthesizing intracellular magnetic particles. Although various morphotypes of magnetotactic bacteria have been observed in the environment, bacterial strains available in pure culture are currently limited to a few genera due to difficulties in their enrichment and cultivation. In order to obtain genetic information from uncultured magnetotactic bacteria, a genome preparation method that involves magnetic separation of cells, flow cytometry, and multiple displacement amplification (MDA) using phi29 polymerase was used in this study. The conditions for the MDA reaction using samples containing 1 to 100 cells were evaluated using a pure-culture magnetotactic bacterium, "Magnetospirillum magneticum AMB-1," whose complete genome sequence is available. Uniform gene amplification was confirmed by quantitative PCR (Q-PCR) when 100 cells were used as a template. This method was then applied for genome preparation of uncultured magnetotactic bacteria from complex bacterial communities in an aquatic environment. A sample containing 100 cells of the uncultured magnetotactic coccus was prepared by magnetic cell separation and flow cytometry and used as an MDA template. 16S rRNA sequence analysis of the MDA product from these 100 cells revealed that the amplified genomic DNA was from a single species of magnetotactic bacterium that was phylogenetically affiliated with magnetotactic cocci in the Alphaproteobacteria. The combined use of magnetic separation, flow cytometry, and MDA provides a new strategy to access individual genetic information from magnetotactic bacteria in environmental samples.
Measurement of Mitochondrial Mass by Flow Cytometry during Oxidative Stress.
Doherty, Edward; Perl, Andras
2017-07-01
Properly assessing mitochondrial health is crucial to understand their role in disease. MitoTracker green (MTG) and nonylacridine orange (NAO) are fluorescent probes which have been commonly used to assess mitochondrial mass. This is based on the assumption that both MTG and NAO accumulate in mitochondria regardless of the mitochondrial transmembrane potential (ΔΨ m ). Here, we utilized flow cytometry to evaluate the performance of these probes for assessment of mitochondrial mass relative to forward (FSC) and side scatter (SSC) in human peripheral blood lymphocytes (PBL). In isolated mitochondria, two subpopulations were identified by FSC and SSC measurements which were matched to subpopulations stained by MTG and NAO. The performance of these dyes was examined under oxidative and nitrosative stress induced by rotenone and NOC-18 while N -acetylcysteine (NAC) was employed as an antioxidant. Production of reactive oxygen species (ROS) and ΔΨ m were monitored in parallel. With respect to representation of mitochondrial mass, neither MTG nor NAO was affected by ΔΨ m . However, MTG showed significant correlation with cytosolic and mitochondrial ROS production and nitrosative stress. Our data suggest that NAO may be more suitable than MTG for assessment of mitochondrial mass by flow cytometry during oxidative stress.
Ludwig, D Brett; Trotter, Joseph T; Gabrielson, John P; Carpenter, John F; Randolph, Theodore W
2011-03-15
Subvisible particles in formulations intended for parenteral administration are of concern in the biopharmaceutical industry. However, monitoring and control of subvisible particulates can be complicated by formulation components, such as the silicone oil used for the lubrication of prefilled syringes, and it is difficult to differentiate microdroplets of silicone oil from particles formed by aggregated protein. In this study, we demonstrate the ability of flow cytometry to resolve mixtures comprising subvisible bovine serum albumin (BSA) aggregate particles and silicone oil emulsion droplets with adsorbed BSA. Flow cytometry was also used to investigate the effects of silicone oil emulsions on the stability of BSA, lysozyme, abatacept, and trastuzumab formulations containing surfactant, sodium chloride, or sucrose. To aid in particle characterization, the fluorescence detection capabilities of flow cytometry were exploited by staining silicone oil with BODIPY 493/503 and model proteins with Alexa Fluor 647. Flow cytometric analyses revealed that silicone oil emulsions induced the loss of soluble protein via protein adsorption onto the silicone oil droplet surface. The addition of surfactant prevented protein from adsorbing onto the surface of silicone oil droplets. There was minimal formation of homogeneous protein aggregates due to exposure to silicone oil droplets, although oil droplets with surface-adsorbed trastuzumab exhibited flocculation. The results of this study demonstrate the utility of flow cytometry as an analytical tool for monitoring the effects of subvisible silicone oil droplets on the stability of protein formulations. Copyright © 2010 Elsevier Inc. All rights reserved.
Pinched-flow hydrodynamic stretching of single-cells.
Dudani, Jaideep S; Gossett, Daniel R; Tse, Henry T K; Di Carlo, Dino
2013-09-21
Reorganization of cytoskeletal networks, condensation and decondensation of chromatin, and other whole cell structural changes often accompany changes in cell state and can reflect underlying disease processes. As such, the observable mechanical properties, or mechanophenotype, which is closely linked to intracellular architecture, can be a useful label-free biomarker of disease. In order to make use of this biomarker, a tool to measure cell mechanical properties should accurately characterize clinical specimens that consist of heterogeneous cell populations or contain small diseased subpopulations. Because of the heterogeneity and potential for rare populations in clinical samples, single-cell, high-throughput assays are ideally suited. Hydrodynamic stretching has recently emerged as a powerful method for carrying out mechanical phenotyping. Importantly, this method operates independently of molecular probes, reducing cost and sample preparation time, and yields information-rich signatures of cell populations through significant image analysis automation, promoting more widespread adoption. In this work, we present an alternative mode of hydrodynamic stretching where inertially-focused cells are squeezed in flow by perpendicular high-speed pinch flows that are extracted from the single inputted cell suspension. The pinched-flow stretching method reveals expected differences in cell deformability in two model systems. Furthermore, hydraulic circuit design is used to tune stretching forces and carry out multiple stretching modes (pinched-flow and extensional) in the same microfluidic channel with a single fluid input. The ability to create a self-sheathing flow from a single input solution should have general utility for other cytometry systems and the pinched-flow design enables an order of magnitude higher throughput (65,000 cells s(-1)) compared to our previously reported deformability cytometry method, which will be especially useful for identification of rare cell populations in clinical body fluids in the future.
DNA-based probes for flow cytometry analysis of endocytosis and recycling.
Dumont, Claire; Czuba, Ewa; Chen, Moore; Villadangos, Jose A; Johnston, Angus P R; Mintern, Justine D
2017-04-01
The internalization of proteins plays a key role in cell development, cell signaling and immunity. We have previously developed a specific hybridization internalization probe (SHIP) to quantitate the internalization of proteins and particles into cells. Herein, we extend the utility of SHIP to examine both the endocytosis and recycling of surface receptors using flow cytometry. SHIP was used to monitor endocytosis of membrane-bound transferrin receptor (TFR) and its soluble ligand transferrin (TF). SHIP enabled measurements of the proportion of surface molecules internalized, the internalization kinetics and the proportion and rate of internalized molecules that recycle to the cell surface with time. Using this method, we have demonstrated the internalization and recycling of holo-TF and an antibody against the TFR behave differently. This assay therefore highlights the implications of receptor internalization and recycling, where the internalization of the receptor-antibody complex behaves differently to the receptor-ligand complex. In addition, we observe distinct internalization patterns for these molecules expressed by different subpopulations of primary cells. SHIP provides a convenient and high throughput technique for analysis of trafficking parameters for both cell surface receptors and their ligands. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Detection and quantification of rituximab in the human urine.
Jacobs, Roland; Langer-Jacobus, Thais; Duong, Michelle; Stahl, Klaus; Haller, Hermann; Schmidt, Reinhold E; Schiffer, Mario
2017-12-01
B cell depletion by rituximab treatment might be inefficient in patients suffering from nephrotic syndrome. Due to the impaired glomerular filtration barrier a significant portion of the therapeutic antibody might be lost into the urinary space. In order to determine the amount of rituximab in the urine of such patients, CD20+ Daudi cells were stained with the patients' urine followed by a fluorochrome-labeled secondary antibody. Mean fluorescence intensity of that way labeled Daudi cells was determined by flow cytometry. Control samples with defined rituximab concentrations were used to create standard curves. The analyses revealed that all nephelometric IgG+ urine samples tested also manifested rituximab at concentrations between 100 and 46,707μg/L. The flow cytometry-based approach is an easy and reliable method to assess rituximab in patients' urine samples for monitoring individual rituximab treatment courses in all patients co-presenting impaired renal filtration. Presence of such antibodies in the urine could be considered as criteria to modify the formulation or modality of rituximab delivery in order to prevent the loss of the therapeutic antibodies and thereby ensuring efficacy of the therapy. Copyright © 2017 Elsevier B.V. All rights reserved.
Fluorescent-Antibody Measurement Of Cancer-Cell Urokinase
NASA Technical Reports Server (NTRS)
Morrison, Dennis R.
1993-01-01
Combination of laboratory techniques provides measurements of amounts of urokinase in and between normal and cancer cells. Includes use of fluorescent antibodies specific against different forms of urokinase-type plasminogen activator, (uPA), fluorescence microscopy, quantitative analysis of images of sections of tumor tissue, and flow cytometry of different uPA's and deoxyribonucleic acid (DNA) found in suspended-tumor-cell preparations. Measurements provide statistical method for indicating or predicting metastatic potentials of some invasive tumors. Assessments of metastatic potentials based on such measurements used in determining appropriate follow-up procedures after surgical removal of tumors.
Reibetanz, Uta; Halozan, David; Brumen, Milan; Donath, Edwin
2007-06-01
Polyelectrolyte multilayer sensor capsules, 5 microm in diameter, which contained fluorescein-labeled poly(acrylic acid) (PAAAF) as pH-sensitive reporter molecules, were fabricated and employed to explore their endocytotic uptake into HEK 293T cells by flow cytometry. The percentage of capsules residing in the endolysosomal compartment was estimated from the fluorescence intensity decrease caused by acidification. Capsules attached to the extracellular surface of the plasma membrane were identified by trypan blue quenching. The number of capsules in the cytoplasm was rather small, being below the detection limit of the method. The advantages of polyelectrolyte multilayer capsules are that the fluorophore is protected from interaction with cellular compartments and that the multilayer can be equipped with additional functions.
Annual Progress Report FY-92. Volume 1
1993-01-21
Billups, L Flow Cytom Resh Psychologist 12 0180 CS Hamm, C DCI 7 DESCRIPTION GRADE MOS BRANCH NAME ACTIVITY Kyle Metabolic Unit Nursing Service Supv...3349 Salata, Kalman PhD. Mitogen-Inducible T Suppressor Cell 13 Assay by Flow Cytometry (12/89) 3350 Salata, Kalman PhD. Flow Cytometric Analysis of...17 Immunotherapy (3/90) 3354 Salata, Kalman PhD. Two Way Mixed Lymphocyte Culture: 18 Analysis by Two Color Flow Cytometry (4/90) 3355 Salata, Kalman
Teaching the Microbial Growth Curve Concept Using Microalgal Cultures and Flow Cytometry
ERIC Educational Resources Information Center
Forget, Nathalie; Belzile, Claude; Rioux, Pierre; Nozais, Christian
2010-01-01
The microbial growth curve is widely studied within microbiology classes and bacteria are usually the microbial model used. Here, we describe a novel laboratory protocol involving flow cytometry to assess the growth dynamics of the unicellular microalgae "Isochrysis galbana." The algal model represents an appropriate alternative to…
Targeting the Nociceptin/Orphanin FQ Receptor for Scleroderma Therapy
2015-12-01
bottom well; the number of migrating cells is quantified by flow cytometry. In the aortic ring assay, freshly isolated thoracic aorta rings will...quantified by flow cytometry. In the aortic ring assay, freshly isolated thoracic aorta rings will be harvested and mounted in a small-vessel myograph. KO
Rationale: The evaluation of sputum leukocytes by flow cytometry is an opportunity to assess characteristics of cells residing in the central airways, yet it is hampered by certain inherent properties of sputum including mucus and large amounts of contaminating cells and debris. ...
Schuck, Desirée Cigaran; Ribeiro, Ramira Yuri; Nery, Arthur A; Ulrich, Henning; Garcia, Célia R S
2011-11-01
Melatonin and its derivatives modulate the Plasmodium falciparum and Plasmodium chabaudi cell cycle. Flow cytometry was employed together with the nucleic acid dye YOYO-1 allowing precise discrimination between mono- and multinucleated forms of P. falciparum-infected red blood cell. The use of YOYO-1 permitted excellent discrimination between uninfected and infected red blood cells as well as between early and late parasite stages. Fluorescence intensities of schizont-stage parasites were about 10-fold greater than those of ring-trophozoite form parasites. Melatonin and related indolic compounds including serotonin, N-acetyl-serotonin and tryptamine induced an increase in the percentage of multinucleated forms compared to non-treated control cultures. YOYO-1 staining of infected erythrocyte and subsequent flow cytometry analysis provides a powerful tool in malaria research for screening of bioactive compounds. Copyright © 2011 International Society for Advancement of Cytometry.
Red blood cell microparticles and blood group antigens: an analysis by flow cytometry
Canellini, Giorgia; Rubin, Olivier; Delobel, Julien; Crettaz, David; Lion, Niels; Tissot, Jean-Daniel
2012-01-01
Background The storage of blood induces the formation of erythrocytes-derived microparticles. Their pathogenic role in blood transfusion is not known so far, especially the risk to trigger alloantibody production in the recipient. This work aims to study the expression of clinically significant blood group antigens on the surface of red blood cells microparticles. Material and methods Red blood cells contained in erythrocyte concentrates were stained with specific antibodies directed against blood group antigens and routinely used in immunohematology practice. After inducing erythrocytes vesiculation with calcium ionophore, the presence of blood group antigens was analysed by flow cytometry. Results The expression of several blood group antigens from the RH, KEL, JK, FY, MNS, LE and LU systems was detected on erythrocyte microparticles. The presence of M (MNS1), N (MNS2) and s (MNS4) antigens could not be demonstrated by flow cytometry, despite that glycophorin A and B were identified on microparticles using anti-CD235a and anti-MNS3. Discussion We conclude that blood group antigens are localized on erythrocytes-derived microparticles and probably keep their immunogenicity because of their capacity to bind specific antibody. Selective segregation process during vesiculation or their ability to elicit an immune response in vivo has to be tested by further studies. PMID:22890266
An imaging flow cytometry method to assess ricin trafficking in A549 human lung epithelial cells.
Jenner, Dominic; Chong, Damien; Walker, Nicola; Green, A Christopher
2018-02-01
The endocytosis and trafficking of ricin in mammalian cells is an important area of research for those producing ricin anti-toxins and other ricin therapeutics. Ricin trafficking is usually observed by fluorescence microscopy techniques. This gives good resolution and leads to a detailed understanding of the internal movement of ricin within cells. However, microscopy techniques are often hampered by complex analysis and quantification techniques, and the inability to look at ricin trafficking in large populations of cells. In these studies we have directly labelled ricin and assessed if its trafficking can be observed using Imaging Flow Cytometry (IFC) both to the cytoplasmic region of cells and specifically to the Golgi apparatus. Using IDEAS® data analysis software the specific fluorescence location of the ricin within the cells was analysed. Then, using cytoplasmic masking techniques to quantify the number of cells with endocytosed cytoplasmic ricin or cells with Golgi-associated ricin, kinetic endocytosis curves were generated. Here we present, to the authors' knowledge, the first example of using imaging flow cytometry for evaluating the subcellular transport of protein cargo, using the trafficking of ricin toxin in lung cells as a model. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.
Comparison of six different methods to calculate cell densities.
Camacho-Fernández, Carolina; Hervás, David; Rivas-Sendra, Alba; Marín, Mª Pilar; Seguí-Simarro, Jose M
2018-01-01
For in vitro culture of plant and animal cells, one of the critical steps is to adjust the initial cell density. A typical example of this is isolated microspore culture, where specific cell densities have been determined for different species. Out of these ranges, microspore growth is not induced, or is severely reduced. A similar situation occurs in many other plant and animal cell culture systems. Traditionally, researchers have used counting chambers (hemacytometers) to calculate cell densities, but little is still known about their technical advantages. In addition, much less information is available about other, alternative methods. In this work, using isolated eggplant microspore cultures and fluorescent beads (fluorospheres) as experimental systems, we performed a comprehensive comparison of six methods to calculate cell densities: (1) a Neubauer improved hemacytometer, (2) an automated cell counter, (3) a manual-counting method, and three flow cytometry methods based on (4) autofluorescence, (5) propidium iodide staining, and (6) side scattered light (SSC). Our results show that from a technical perspective, hemacytometers are the most reasonable option for cell counting, which may explain their widely spread use. Automated cell counters represent a good compromise between precision and affordability, although with limited accuracy. Finally, the methods based on flow cytometry were, by far, the best in terms of reproducibility and agreement between them, but they showed deficient accuracy and precision. Together, our results show a thorough technical evaluation of each counting method, provide unambiguous arguments to decide which one is the most convenient for the particular case of each laboratory, and in general, shed light into the best way to determine cell densities for in vitro cell cultures. They may have an impact in such a practice not only in the context of microspore culture, but also in any other plant cell culture procedure, or in any process involving particle counting.
Current status of antifungal susceptibility testing methods.
Arikan, Sevtap
2007-11-01
Antifungal susceptibility testing is a very dynamic field of medical mycology. Standardization of in vitro susceptibility tests by the Clinical and Laboratory Standards Institute (CLSI) and the European Committee for Antimicrobial Susceptibility Testing (EUCAST), and current availability of reference methods constituted the major remarkable steps in the field. Based on the established minimum inhibitory concentration (MIC) breakpoints, it is now possible to determine the susceptibilities of Candida strains to fluconazole, itraconazole, voriconazole, and flucytosine. Moreover, utility of fluconazole antifungal susceptibility tests as an adjunct in optimizing treatment of candidiasis has now been validated. While the MIC breakpoints and clinical significance of susceptibility testing for the remaining fungi and antifungal drugs remain yet unclear, modifications of the available methods as well as other methodologies are being intensively studied to overcome the present drawbacks and limitations. Among the other methods under investigation are Etest, colorimetric microdilution, agar dilution, determination of fungicidal activity, flow cytometry, and ergosterol quantitation. Etest offers the advantage of practical application and favorable agreement rates with the reference methods that are frequently above acceptable limits. However, MIC breakpoints for Etest remain to be evaluated and established. Development of commercially available, standardized colorimetric panels that are based on CLSI method parameters has added more to the antifungal susceptibility testing armamentarium. Flow cytometry, on the other hand, appears to offer rapid susceptibility testing but requires specified equipment and further evaluation for reproducibility and standardization. Ergosterol quantitation is another novel approach, which appears potentially beneficial particularly in discrimination of azole-resistant isolates from heavy trailers. The method is yet investigational and requires to be further studied. Developments in methodology and applications of antifungal susceptibility testing will hopefully provide enhanced utility in clinical guidance of antifungal therapy. However, and particularly in immunosuppressed host, in vitro susceptibility is and will remain only one of several factors that influence clinical outcome.
Node-pore sensing enables label-free surface-marker profiling of single cells.
Balakrishnan, Karthik R; Whang, Jeremy C; Hwang, Richard; Hack, James H; Godley, Lucy A; Sohn, Lydia L
2015-03-03
Flow cytometry is a ubiquitous, multiparametric method for characterizing cellular populations. However, this method can grow increasingly complex with the number of proteins that need to be screened simultaneously: spectral emission overlap of fluorophores and the subsequent need for compensation, lengthy sample preparation, and multiple control tests that need to be performed separately must all be considered. These factors lead to increased costs, and consequently, flow cytometry is performed in core facilities with a dedicated technician operating the instrument. Here, we describe a low-cost, label-free microfluidic method that can determine the phenotypic profiles of single cells. Our method employs Node-Pore Sensing to measure the transit times of cells as they interact with a series of different antibodies, each corresponding to a specific cell-surface antigen, that have been functionalized in a single microfluidic channel. We demonstrate the capabilities of our method not only by screening two acute promyelocytic leukemia human cells lines (NB4 and AP-1060) for myeloid antigens, CD13, CD14, CD15, and CD33, simultaneously, but also by distinguishing a mixture of cells of similar size—AP-1060 and NALM-1—based on surface markers CD13 and HLA-DR. Furthermore, we show that our method can screen complex subpopulations in clinical samples: we successfully identified the blast population in primary human bone marrow samples from patients with acute myeloid leukemia and screened these cells for CD13, CD34, and HLA-DR. We show that our label-free method is an affordable, highly sensitive, and user-friendly technology that has the potential to transform cellular screening at the benchside.
NASA Astrophysics Data System (ADS)
Simmons, L. J.; Fobbe, D. J.; Berges, J. A.
2016-02-01
Understanding the dynamics of phytoplankton communities has traditionally focused on differences in growth and related processes among taxa. It is now appreciated that differences in mortality could be equally important in contributing to these dynamics. Studying mortality in communities is difficult, especially on relevant time scales, which could be as short as hours to days. Flow cytometry can potentially provide solutions, because it can allow discrimination of different taxa, and when combined with staining, distinguish live and dead cells. We applied flow cytometry and staining to phytoplankton communities in a model system: a small, well-studied, urban pond in southeastern Wisconsin. Using flow cytometry, it was possible to resolve up to six dominant taxa (most <37 µm) and track them through an annual cycle. However, the axes traditionally used, forward scatter (FSC, related to cell size) and red fluorescence (FL3, related to chlorophyll a content) offered poor discrimination. Addition of orange fluorescence (FL2, traditionally related to phycobilipigments) and side scatter (SSC, related to cell surface characteristics) improved separation of taxa, but reproducibility (i.e. the specific position of the taxa on axes) was also more sensitive to environmental variation in the case of the fluorescence parameters. Dead cells could be distinguished by green fluorescence (FL1, using SYTOX Green©), but the stain also affected other fluorescence channels, requiring compensation. Correlations of numbers of dead cells with environmental factors (e.g. temperature, nutrient concentrations, irradiance) were generally poor, suggesting the greater importance of biotic versus abiotic variables in community mortality dynamics. Ongoing work is focusing on the effects of viral pathogens, grazing and allelopathic interactions using experimental manipulations and individual-based modeling.
Fluorescence-based detection and quantification of features of cellular senescence.
Cho, Sohee; Hwang, Eun Seong
2011-01-01
Cellular senescence is a spontaneous organismal defense mechanism against tumor progression which is raised upon the activation of oncoproteins or other cellular environmental stresses that must be circumvented for tumorigenesis to occur. It involves growth-arrest state of normal cells after a number of active divisions. There are multiple experimental routes that can drive cells into a state of senescence. Normal somatic cells and cancer cells enter a state of senescence upon overexpression of oncogenic Ras or Raf protein or by imposing certain kinds of stress such as cellular tumor suppressor function. Both flow cytometry and confocal imaging analysis techniques are very useful in quantitative analysis of cellular senescence phenomenon. They allow quantitative estimates of multiple different phenotypes expressed in multiple cell populations simultaneously. Here we review the various types of fluorescence methodologies including confocal imaging and flow cytometry that are frequently utilized to study a variety of senescence. First, we discuss key cell biological changes occurring during senescence and review the current understanding on the mechanisms of these changes with the goal of improving existing protocols and further developing new ones. Next, we list specific senescence phenotypes associated with each cellular trait along with the principles of their assay methods and the significance of the assay outcomes. We conclude by selecting appropriate references that demonstrate a typical example of each method. Copyright © 2011 Elsevier Inc. All rights reserved.
Ahn, Ilyoung; Kim, Tae-Sung; Jung, Eun-Sun; Yi, Jung-Sun; Jang, Won-Hee; Jung, Kyoung-Mi; Park, Miyoung; Jung, Mi-Sook; Jeon, Eun-Young; Yeo, Kyeong-Uk; Jo, Ji-Hoon; Park, Jung-Eun; Kim, Chang-Yul; Park, Yeong-Chul; Seong, Won-Keun; Lee, Ai-Young; Chun, Young Jin; Jeong, Tae Cheon; Jeung, Eui Bae; Lim, Kyung-Min; Bae, SeungJin; Sohn, Soojung; Heo, Yong
2016-10-01
Local lymph node assay: 5-bromo-2-deoxyuridine-flow cytometry method (LLNA: BrdU-FCM) is a modified non-radioisotopic technique with the additional advantages of accommodating multiple endpoints with the introduction of FCM, and refinement and reduction of animal use by using a sophisticated prescreening scheme. Reliability and accuracy of the LLNA: BrdU-FCM was determined according to OECD Test Guideline (TG) No. 429 (Skin Sensitization: Local Lymph Node Assay) performance standards (PS), with the participation of four laboratories. Transferability was demonstrated through successfully producing stimulation index (SI) values for 25% hexyl cinnamic aldehyde (HCA) consistently greater than 3, a predetermined threshold, by all participating laboratories. Within- and between-laboratory reproducibility was shown using HCA and 2,4-dinitrochlorobenzene, in which EC2.7 values (the estimated concentrations eliciting an SI of 2.7, the threshold for LLNA: BrdU-FCM) fell consistently within the acceptance ranges, 0.025-0.1% and 5-20%, respectively. Predictive capacity was tested using the final protocol version 1.3 for the 18 reference chemicals listed in OECD TG 429, of which results showed 84.6% sensitivity, 100% specificity, and 88.9% accuracy compared with the original LLNA. The data presented are considered to meet the performance criteria for the PS, and its predictive capacity was also sufficiently validated. Copyright © 2016 Elsevier Inc. All rights reserved.
Lee, Wonmok; Ha, Jung-Sook; Ryoo, Nam-Hee
2016-09-01
The cobas u 701, a new automated image-based urine sediment analyzer, was introduced recently. In this study, we compared its performance with that of UF-1000i flow cytometry and manual microscopy in the examination of urine sediments. Precision, linearity, and carry-over were determined for the two urine sediment analyzers. For a comparison of the method, 300 urine samples were examined by the automated analyzers and by manual microscopy using a KOVA chamber. Within-run coefficients of variation (CVs) for the control materials were 7.0-8.8% and 1.7-5.7% for the cobas u 701 and UF-1000i systems, respectively. Between-run CVs were 8.5-9.8% and 2.7-5.4%, respectively. Both instruments showed good linearity and negligible carry-over. For red blood cells (RBC), white blood cells (WBC), and epithelial cells (EPI), the overall concordance rates within one grade of difference among the three methods were good (78.6-86.0%, 88.7-93.8%, and 81.3-90.7%, respectively). The concordance rate for casts was poor (66.5-68.9%). Compared with manual microscopy, the two automated sediment analyzers tested in this study showed satisfactory analytical performances for RBC, WBC, and EPI. However, for other urine sediment particles confirmation by visual microscopy is still required. © 2016 Wiley Periodicals, Inc.
Genome survey sequencing of red swamp crayfish Procambarus clarkii.
Shi, Linlin; Yi, Shaokui; Li, Yanhe
2018-06-21
Red swamp crayfish, Procambarus clarkii, presently is an important aquatic commercial species in China. The crayfish is a hot area of research focus, and its genetic improvement is quite urgent for the crayfish aquaculture in China. However, the knowledge of its genomic landscape is limited. In this study, a survey of P. clarkii genome was investigated based on Illumina's Solexa sequencing platform. Meanwhile, its genome size was estimated using flow cytometry. Interestingly, the genome size estimated is about 8.50 Gb by flow cytometry and 1.86 Gb with genome survey sequencing. Based on the assembled genome sequences, total of 136,962 genes and 152,268 exons were predicted, and the predicted genes ranged from 150 to 12,807 bp in length. The survey sequences could help accelerate the progress of gene discovery involved in genetic diversity and evolutionary analysis, even though it could not successfully applied for estimation of P. clarkii genome size.
Liu, Ben; Zhong, Mintao; Lun, Yongzhi; Wang, Xiaoli; Sun, Wenchang; Li, Xingyun; Ning, Anhong; Cao, Jing; Zhang, Wei; Liu, Lei; Huang, Min
2012-01-01
An apoptosis correlated molecule-protein Latcripin-1 of Lentinula edodes C(91-3)-was expressed and characterized in Pichia pastoris GS115. The total RNA was obtained from Lentinula edodes C(91-3). According to the transcriptome, the full-length gene of Latcripin-1 was isolated with 3'-Full Rapid Amplification of cDNA Ends (RACE) and 5'-Full RACE methods. The full-length gene was inserted into the secretory expression vector pPIC9K. The protein Latcripin-1 was expressed in Pichia pastoris GS115 and analyzed by Sodium Dodecylsulfonate Polyacrylate Gel Electrophoresis (SDS-PAGE) and Western blot. The Western blot showed that the protein was expressed successfully. The biological function of protein Latcripin-1 on A549 cells was studied with flow cytometry and the 3-(4,5-Dimethylthiazol-2-yl)-2,5-Diphenyl-tetrazolium Bromide (MTT) method. The toxic effect of protein Latcripin-1 was detected with the MTT method by co-culturing the characterized protein with chick embryo fibroblasts. The MTT assay results showed that there was a great difference between protein Latcripin-1 groups and the control group (p < 0.05). There was no toxic effect of the characterized protein on chick embryo fibroblasts. The flow cytometry showed that there was a significant difference between the protein groups of interest and the control group according to apoptosis function (p < 0.05). At the same time, cell ultrastructure observed by transmission electron microscopy supported the results of flow cytometry. The work demonstrates that protein Latcripin-1 can induce apoptosis of human lung cancer cells A549 and brings new insights into and advantages to finding anti-tumor proteins.
Liu, Ben; Zhong, Mintao; Lun, Yongzhi; Wang, Xiaoli; Sun, Wenchang; Li, Xingyun; Ning, Anhong; Cao, Jing; Zhang, Wei; Liu, Lei; Huang, Min
2012-01-01
An apoptosis correlated molecule—protein Latcripin-1 of Lentinula edodes C91–3—was expressed and characterized in Pichia pastoris GS115. The total RNA was obtained from Lentinula edodes C91–3. According to the transcriptome, the full-length gene of Latcripin-1 was isolated with 3′-Full Rapid Amplification of cDNA Ends (RACE) and 5′-Full RACE methods. The full-length gene was inserted into the secretory expression vector pPIC9K. The protein Latcripin-1 was expressed in Pichia pastoris GS115 and analyzed by Sodium Dodecylsulfonate Polyacrylate Gel Electrophoresis (SDS-PAGE) and Western blot. The Western blot showed that the protein was expressed successfully. The biological function of protein Latcripin-1 on A549 cells was studied with flow cytometry and the 3-(4,5-Dimethylthiazol-2-yl)-2,5-Diphenyl-tetrazolium Bromide (MTT) method. The toxic effect of protein Latcripin-1 was detected with the MTT method by co-culturing the characterized protein with chick embryo fibroblasts. The MTT assay results showed that there was a great difference between protein Latcripin-1 groups and the control group (p < 0.05). There was no toxic effect of the characterized protein on chick embryo fibroblasts. The flow cytometry showed that there was a significant difference between the protein groups of interest and the control group according to apoptosis function (p < 0.05). At the same time, cell ultrastructure observed by transmission electron microscopy supported the results of flow cytometry. The work demonstrates that protein Latcripin-1 can induce apoptosis of human lung cancer cells A549 and brings new insights into and advantages to finding anti-tumor proteins. PMID:22754362
Sabzehei, Faezeh; Kouhpayeh, Shirin; Dastjerdeh, Mansoureh Shahbazi; Khanahmad, Hossein; Salehi, Rasoul; Naderi, Shamsi; Taghizadeh, Razieh; Rabiei, Parisa; Hejazi, Zahra; Shariati, Laleh
2017-01-01
Background: Gene editing technology has created a revolution in the field of genome editing. The three of the most famous tools in gene editing technology are zinc finger nucleases (ZFNs), transcription activator-like effector nucleases, clustered regularly interspaced short palindromic repeats (CRISPR), and CRISPR-associated systems. As their predictable nature, it is necessary to assess their efficiency. There are some methods for this purpose, but most of them are time labor and complicated. Here, we introduce a new prokaryotic reporter system, which makes it possible to evaluate the efficiency of gene editing tools faster, cheaper, and simpler than previous methods. Materials and Methods: At first, the target sites of a custom ZFN, which is designed against a segment of ampicillin resistance gene, were cloned on both sides of green fluorescent protein (GFP) gene to construct pPRO-GFP. Then pPRO-GFP was transformed into Escherichia coli TOP10F’ that contains pZFN (contains expression cassette of a ZFN against ampicillin resistant gene), or p15A-KanaR as a negative control. The transformed bacteria were cultured on three separate media that contained ampicillin, kanamycin, and ampicillin + kanamycin; then the resulted colonies were assessed by flow cytometry. Results: The results of flow cytometry showed a significant difference between the case (bacteria contain pZFN) and control (bacteria contain p15A, KanaR) in MFI (Mean Fluorescence Intensity) (P < 0.0001). Conclusion: According to ZFN efficiency, it can bind and cut the target sites, the bilateral cutting can affect the intensity of GFP fluorescence. Our flow cytometry results showed that this ZFN could reduce the intensity of GFP color and colony count of bacteria in media containing amp + kana versus control sample. PMID:29285485
Han, Daehoon; Hong, Jinkee; Kim, Hyun Cheol; Sung, Jong Hwan; Lee, Jong Bum
2013-11-01
Many highly sensitive protein detection techniques have been developed and have played an important role in the analysis of proteins. Herein, we report a novel technique that can detect proteins sensitively and effectively using aptamer-based DNA nanostructures. Thrombin was used as a target protein and aptamer was used to capture fluorescent dye-labeled DNA nanobarcodes or thrombin on a microsphere. The captured DNA nanobarcodes were replaced by a thrombin and aptamer interaction. The detection ability of this approach was confirmed by flow cytometry with different concentrations of thrombin. Our detection method has great potential for rapid and simple protein detection with a variety of aptamers.
Time-resolved fluorescence decay measurements for flowing particles
Deka, C.; Steinkamp, J.A.
1999-06-01
Time-resolved fluorescence decay measurements are disclosed for flowing particles. An apparatus and method for the measurement and analysis of fluorescence for individual cells and particles in flow are described, wherein the rapid measurement capabilities of flow cytometry and the robust measurement and analysis procedures of time-domain fluorescence lifetime spectroscopy are combined. A pulse-modulated CW laser is employed for excitation of the particles. The characteristics and the repetition rate of the excitation pulses can be readily adjusted to accommodate for fluorescence decays having a wide range of lifetimes. 12 figs.
Time-resolved fluorescence decay measurements for flowing particles
Deka, Chiranjit; Steinkamp, John A.
1999-01-01
Time-resolved fluorescence decay measurements for flowing particles. An apparatus and method for the measurement and analysis of fluorescence for individual cells and particles in flow are described, wherein the rapid measurement capabilities of flow cytometry and the robust measurement and analysis procedures of time-domain fluorescence lifetime spectroscopy are combined. A pulse-modulated cw laser is employed for excitation of the particles. The characteristics and the repetition rate of the excitation pulses can be readily adjusted to accommodate for fluorescence decays having a wide range of lifetimes.
Determination of chitin content in fungal cell wall: an alternative flow cytometric method.
Costa-de-Oliveira, Sofia; Silva, Ana P; Miranda, Isabel M; Salvador, Alexandre; Azevedo, Maria M; Munro, Carol A; Rodrigues, Acácio G; Pina-Vaz, Cidália
2013-03-01
The conventional methods used to evaluate chitin content in fungi, such as biochemical assessment of glucosamine release after acid hydrolysis or epifluorescence microscopy, are low throughput, laborious, time-consuming, and cannot evaluate a large number of cells. We developed a flow cytometric assay, efficient, and fast, based on Calcofluor White staining to measure chitin content in yeast cells. A staining index was defined, its value was directly related to chitin amount and taking into consideration the different levels of autofluorecence. Twenty-two Candida spp. and four Cryptococcus neoformans clinical isolates with distinct susceptibility profiles to caspofungin were evaluated. Candida albicans clinical isolate SC5314, and isogenic strains with deletions in chitin synthase 3 (chs3Δ/chs3Δ) and genes encoding predicted GlycosylPhosphatidylInositol (GPI)-anchored proteins (pga31Δ/Δ and pga62Δ/Δ), were used as controls. As expected, the wild-type strain displayed a significant higher chitin content (P < 0.001) than chs3Δ/chs3Δ and pga31Δ/Δ especially in the presence of caspofungin. Ca. parapsilosis, Ca. tropicalis, and Ca. albicans showed higher cell wall chitin content. Although no relationship between chitin content and antifungal drug susceptibility phenotype was found, an association was established between the paradoxical growth effect in the presence of high caspofungin concentrations and the chitin content. This novel flow cytometry protocol revealed to be a simple and reliable assay to estimate cell wall chitin content of fungi. Copyright © 2013 International Society for Advancement of Cytometry.
The Means: Cytometry and Mass Spectrometry Converge in a Single Cell Deep Profiling Platform
Weis-Garcia, Frances; Bandura, Dmitry; Baranov, Vladimir; Ornatsky, Olga; Tanner, Scott
2013-01-01
Inductively Coupled Plasma Mass Spectrometry (ICP-MS) is a distinct flavor of mass spectrometry that has had little association with cell biology: it remains the state of the art for the determination of the atomic composition of materials. Unrelatedly, flow cytometry is the superior method for distinguishing the heterogeneity of cells through the determination of antigen signatures using tagged antibodies. Simply replacing fluorophore tags with stable isotopes of the heavy metals, and measuring these cell-by-cell with ICP-MS, dramatically increases the number of probes that can be simultaneously measured in cytometry and enables a transformative increase in the resolution of rare cell populations in complex biological samples. While this can be thought of as a novel incarnation of single-cell targeted proteomics, the metal-labeling reagents, ICP-MS of single cells, and accompanying informatics comprise a new field of technology termed Mass Cytometry. While the conception of mass cytometry is simple the embodiment to address the issues of multi-parameter flow cytometry has been far more challenging. There are many elements, and many more stable isotopes of those elements, that might be used as distinct reporter tags. Still, there are many approaches to conjugating metals to antibodies (or other affinity reagents) and work in this area along with developing new applications is ongoing. The mass resolution and linear (quantitative) dynamic range of ICP-MS allows those many stable isotopes to be measured simultaneously and without the spectral overlap issues that limit fluorescence assay. However, the adaptation of ICP-MS to allow high-speed simultaneous measurement with single cell distinction at high throughput required innovation of the cell introduction system, ion optics (sampling, transmission and beam-shaping), mass analysis, and signal handling and processing. An overview of “the nuts and bolts” of Mass Cytometry is presented.
Multispectral Imaging Broadens Cellular Analysis
NASA Technical Reports Server (NTRS)
2007-01-01
Amnis Corporation, a Seattle-based biotechnology company, developed ImageStream to produce sensitive fluorescence images of cells in flow. The company responded to an SBIR solicitation from Ames Research Center, and proposed to evaluate several methods of extending the depth of field for its ImageStream system and implement the best as an upgrade to its commercial products. This would allow users to view whole cells at the same time, rather than just one section of each cell. Through Phase I and II SBIR contracts, Ames provided Amnis the funding the company needed to develop this extended functionality. For NASA, the resulting high-speed image flow cytometry process made its way into Medusa, a life-detection instrument built to collect, store, and analyze sample organisms from erupting hydrothermal vents, and has the potential to benefit space flight health monitoring. On the commercial end, Amnis has implemented the process in ImageStream, combining high-resolution microscopy and flow cytometry in a single instrument, giving researchers the power to conduct quantitative analyses of individual cells and cell populations at the same time, in the same experiment. ImageStream is also built for many other applications, including cell signaling and pathway analysis; classification and characterization of peripheral blood mononuclear cell populations; quantitative morphology; apoptosis (cell death) assays; gene expression analysis; analysis of cell conjugates; molecular distribution; and receptor mapping and distribution.
2012-01-01
Background A mobile health unit may be useful to follow up adult and pediatric patients on antiretroviral treatment and living in remote areas devoid of laboratory facilities. The study evaluated the use of the simplified, robust, single-plateform, volumetric, pan-leucogating Auto40 flow cytometer (Apogee Flow Systems Ltd, Hemel Hempstead, UK) for CD4 T cell numeration in a mobile unit, compared against a reference flow cytometry method. Methods The therapeutic mobile unit of the Laboratoire National de Santé Hygiène Mobile, Yaoundé, Cameroon, was equipped with the Auto40. A FACSCalibur flow cytometer (Becton Dickinson Immuno-cytometry System, San Jose, CA, USA) was used as reference method. EDTA-blood samples from volunteers were first subjected to CD4 T cell count in the mobile unit, and an aliquot was sent within 4 hours to Centre International de Référence Chantal Biya, Yaoundé, for FACSCalibur assay. Results Two HIV screening campaigns with the mobile unit were organised in December 2009 and January 2010. The campaign in the suburb of Yaoundé which was 20 km from the reference laboratory included 188 volunteers comprising 93 children less than 5 years old. The campaign in Ambang Bikok (53 km far from Yaoundé) included 69 adult volunteers. In Yaoundé suburb, mean ± standard deviation (SD) CD4 T cell count was 996 ± 874 cells/μl by Auto40, and 989 ± 883 cells/μl by FACSCalibur; in Ambang Bikok, mean ± SD CD4 T cell count was 1041 ± 317 cells/μl by Auto40, and 1032 ± 294 cells/μl by FACSCalibur. Results by Auto40 and FACSCalibur were highly correlated in Yaoundé (r2 = 0.982) as in Ambang Bikok (r2 = 0.921). Bland-Altman analysis showed a close agreement between Auto40 and FACSCalibur results expressed in absolute count as in percentage in Yaoundé and Ambang Bikok. When pooling the 257 CD4 T cell count measurements, the Auto40 yielded a mean difference of +7.6 CD4 T cells/μl higher than by reference flow cytometry; and the sensitivity and specificity of Auto40 in enumerating absolute CD4 T cell counts of less than 200 cells/μl were 87% and 99%, respectively, and in enumerating absolute CD4 T cell counts of less than 350 cells/μl were 87% and 98%, respectively. The intrarun and interun precisions of the Auto40 assay assessed in the mobile unit were 5.5% and 7.9%, respectively. Conclusions The Auto40 flow cytometer installed in a therapeutic mobile unit and operated far from its reference laboratory gave a perfect correlation with the reference method, and could be useful in carrying out immunological monitoring of HIV-infected patients living in areas without access to laboratory facilities. PMID:22309994
Flow cytometry and real-time quantitative PCR as tools for assessing plasmid persistence.
Loftie-Eaton, Wesley; Tucker, Allison; Norton, Ann; Top, Eva M
2014-09-01
The maintenance of a plasmid in the absence of selection for plasmid-borne genes is not guaranteed. However, plasmid persistence can evolve under selective conditions. Studying the molecular mechanisms behind the evolution of plasmid persistence is key to understanding how plasmids are maintained under nonselective conditions. Given the current crisis of rapid antibiotic resistance spread by multidrug resistance plasmids, this insight is of high medical relevance. The conventional method for monitoring plasmid persistence (i.e., the fraction of plasmid-containing cells in a population over time) is based on cultivation and involves differentiating colonies of plasmid-containing and plasmid-free cells on agar plates. However, this technique is time-consuming and does not easily lend itself to high-throughput applications. Here, we present flow cytometry (FCM) and real-time quantitative PCR (qPCR) as alternative tools for monitoring plasmid persistence. For this, we measured the persistence of a model plasmid, pB10::gfp, in three Pseudomonas hosts and in known mixtures of plasmid-containing and -free cells. We also compared three performance criteria: dynamic range, resolution, and variance. Although not without exceptions, both techniques generated estimates of overall plasmid loss rates that were rather similar to those generated by the conventional plate count (PC) method. They also were able to resolve differences in loss rates between artificial plasmid persistence assays. Finally, we briefly discuss the advantages and disadvantages for each technique and conclude that, overall, both FCM and real-time qPCR are suitable alternatives to cultivation-based methods for routine measurement of plasmid persistence, thereby opening avenues for high-throughput analyses. Copyright © 2014, American Society for Microbiology. All Rights Reserved.
Kim, Sangsung; Park, Hun-Jun; Byun, Jaemin; Cho, Kyu-Won; Saafir, Talib; Song, Ming-Ke; Yu, Shan Ping; Wagner, Mary; Bao, Gang; Yoon, Young-Sup
2013-01-01
Background While methods for generating cardiomyocytes (CMs) from pluripotent stem cells (PSCs) have been reported, current methods produce heterogeneous mixtures of CMs and non-CM cells. Here, we report an entirely novel system in which PSC-derived CMs are purified by CM-specific molecular beacons (MBs). MBs are nano-scale probes that emit a fluorescence signal when hybridized to target mRNAs. Method and Results Five MBs targeting mRNAs of either cardiac troponin T or myosin heavy chain 6/7 were generated. Among five MBs, a MB targeting myosin heavy chain 6/7 mRNA (MHC1-MB) identified up to 99% of HL-1 CMs, a mouse CM cell line, but < 3% of four non-CM cell types in flow cytometry analysis, indicating that MHC1-MB is specific for identifying CMs. We delivered MHC1-MB into cardiomyogenically differentiated PSCs through nucleofection. The detection rate of CMs was similar to the percentages of cardiac troponin T (TNNT2) or cardiac troponin I (TNNI3)-positive CMs, supporting the specificity of MBs. Finally, MHC1-MB-positive cells were FACS-sorted from mouse and human PSC differentiating cultures and ~97% cells expressed TNNT2- or TNNI3 determined by flow cytometry. These MB-based sorted cells maintained their CM characteristics verified by spontaneous beating, electrophysiologic studies, and expression of cardiac proteins. When transplanted in a myocardial infarction model, MB-based purified CMs improved cardiac function and demonstrated significant engraftment for 4 weeks without forming tumors. Conclusions We developed a novel CM selection system that allows production of highly purified CMs. These purified CMs and this system can be valuable for cell therapy and drug discovery. PMID:23995537
Yang, Hyeri; Na, Jihye; Jang, Won-Hee; Jung, Mi-Sook; Jeon, Jun-Young; Heo, Yong; Yeo, Kyung-Wook; Jo, Ji-Hoon; Lim, Kyung-Min; Bae, SeungJin
2015-05-05
Mouse local lymph node assay (LLNA, OECD TG429) is an alternative test replacing conventional guinea pig tests (OECD TG406) for the skin sensitization test but the use of a radioisotopic agent, (3)H-thymidine, deters its active dissemination. New non-radioisotopic LLNA, LLNA:BrdU-FCM employs a non-radioisotopic analog, 5-bromo-2'-deoxyuridine (BrdU) and flow cytometry. For an analogous method, OECD TG429 performance standard (PS) advises that two reference compounds be tested repeatedly and ECt(threshold) values obtained must fall within acceptable ranges to prove within- and between-laboratory reproducibility. However, this criteria is somewhat arbitrary and sample size of ECt is less than 5, raising concerns about insufficient reliability. Here, we explored various statistical methods to evaluate the reproducibility of LLNA:BrdU-FCM with stimulation index (SI), the raw data for ECt calculation, produced from 3 laboratories. Descriptive statistics along with graphical representation of SI was presented. For inferential statistics, parametric and non-parametric methods were applied to test the reproducibility of SI of a concurrent positive control and the robustness of results were investigated. Descriptive statistics and graphical representation of SI alone could illustrate the within- and between-laboratory reproducibility. Inferential statistics employing parametric and nonparametric methods drew similar conclusion. While all labs passed within- and between-laboratory reproducibility criteria given by OECD TG429 PS based on ECt values, statistical evaluation based on SI values showed that only two labs succeeded in achieving within-laboratory reproducibility. For those two labs that satisfied the within-lab reproducibility, between-laboratory reproducibility could be also attained based on inferential as well as descriptive statistics. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Structure of the Global Nanoscience and Nanotechnology Research Literature
2006-01-01
Transistors, Nature, 424 (6949): 654-657, 2003. Joannopoulos, JD, Meade, RD, Winn, JN, Photonic Crystals: Molding the Flow of Light, Princeton...1.27 Force Microscopy 40 0.10 0.00 Electron Spectroscopy 40 0.10 0.00 Rutherford backscattering spectrometry 38 0.10 0.00 flow cytometry 36 0.09...Backscattering Spectroscopy/Spectrometry • Flow Cytometry • Spectrophotometry (UV-Visible) • Deep Level Transient Spectroscopy • Inductively
Flow cytometric discrimination of seven lineage markers by using two fluorochromes
Boin, Francesco; Giardino Torchia, Maria Letizia; Borrello, Ivan; Noonan, Kimberly A.; Neil, Matthew; Soloski, Mark J.
2017-01-01
Flow cytometry is the primary immunological technique used to analyze multiple parameters on complex cell populations. We present a staining method that identifies major human mononuclear lymphoid and myeloid populations (CD4+ and CD8+ T cells, γδ T cells, B cells, NK cells and monocytes), using only two fluorochromes and a minimal number of cells. Our approach increases the number of markers recordable on most flow cytometers allowing for a deeper and more comprehensive immunophenotyping. PMID:29190813
Annual Progress Report FY-91. Volume 1 and 2.
1992-03-12
Pulmonary Med Tech 11 0644 GS Berger, TA Allergy Microbiologist 12 0403 GS Billups, L Flow Cytom Chemist 12 1320 GS Vacant Pulmonary Kyle Metabolic Unit...Reactions 11 (11/89) 3349 Salata, Kalman PhD. Mitogen-Inducible T Suppressor Cell 12 Assay by Flow Cytometry (12/89) 3350 Salata, Kalman PhD. Flow ...3/90) 3354 Salata, Kalman PhD. Two Way Mixed Lymphocyte Culture: 17 Analysis by Two Color Flow Cytometry (4/90) 3355 Salata, Kalman PhD. Effect of
Multi-channel imaging cytometry with a single detector
NASA Astrophysics Data System (ADS)
Locknar, Sarah; Barton, John; Entwistle, Mark; Carver, Gary; Johnson, Robert
2018-02-01
Multi-channel microscopy and multi-channel flow cytometry generate high bit data streams. Multiple channels (both spectral and spatial) are important in diagnosing diseased tissue and identifying individual cells. Omega Optical has developed techniques for mapping multiple channels into the time domain for detection by a single high gain, high bandwidth detector. This approach is based on pulsed laser excitation and a serial array of optical fibers coated with spectral reflectors such that up to 15 wavelength bins are sequentially detected by a single-element detector within 2.5 μs. Our multichannel microscopy system uses firmware running on dedicated DSP and FPGA chips to synchronize the laser, scanning mirrors, and sampling clock. The signals are digitized by an NI board into 14 bits at 60MHz - allowing for 232 by 174 pixel fields in up to 15 channels with 10x over sampling. Our multi-channel imaging cytometry design adds channels for forward scattering and back scattering to the fluorescence spectral channels. All channels are detected within the 2.5 μs - which is compatible with fast cytometry. Going forward, we plan to digitize at 16 bits with an A-toD chip attached to a custom board. Processing these digital signals in custom firmware would allow an on-board graphics processing unit to display imaging flow cytometry data over configurable scanning line lengths. The scatter channels can be used to trigger data buffering when a cell is present in the beam. This approach enables a low cost mechanically robust imaging cytometer.
Arraud, Nicolas; Gounou, Céline; Turpin, Delphine; Brisson, Alain R
2016-02-01
Plasma contains cell-derived extracellular vesicles (EVs) which participate in various physiopathological processes and have potential biomedical applications. Despite intense research activity, knowledge on EVs is limited mainly due to the difficulty of isolating and characterizing sub-micrometer particles like EVs. We have recently reported that a simple flow cytometry (FCM) approach based on triggering the detection on a fluorescence signal enabled the detection of 50× more Annexin-A5 binding EVs (Anx5+ EVs) in plasma than the conventional FCM approach based on light scattering triggering. Here, we present the application of the fluorescence triggering approach to the enumeration and phenotyping of EVs from platelet free plasma (PFP), focusing on CD41+ and CD235a+ EVs, as well as their sub-populations which bind or do not bind Anx5. Higher EV concentrations were detected by fluorescence triggering as compared to light scattering triggering, namely 40× for Anx5+ EVs, 75× for CD41+ EVs, and 15× for CD235a+ EVs. We found that about 30% of Anx5+ EVs were of platelet origin while only 3% of them were of erythrocyte origin. In addition, a majority of EVs from platelet and erythrocyte origin do not expose PS, in contrast to the classical theory of EV formation. Furthermore, the same PFP samples were analyzed fresh and after freeze-thawing, showing that freeze-thawing processes induce an increase, of about 35%, in the amount of Anx5+ EVs, while the other EV phenotypes remain unchanged. The method of EV detection and phenotyping by fluorescence triggering is simple, sensitive and reliable. We foresee that its application to EV studies will improve our understanding on the formation mechanisms and functions of EVs in health and disease and help the development of EV-based biomarkers. © 2015 International Society for Advancement of Cytometry.
Grigorov, Boyan; Rabilloud, Jessica; Lawrence, Philip; Gerlier, Denis
2011-01-01
Background Measles virus (MV) is a member of the Paramyxoviridae family and an important human pathogen causing strong immunosuppression in affected individuals and a considerable number of deaths worldwide. Currently, measles is a re-emerging disease in developed countries. MV is usually quantified in infectious units as determined by limiting dilution and counting of plaque forming unit either directly (PFU method) or indirectly from random distribution in microwells (TCID50 method). Both methods are time-consuming (up to several days), cumbersome and, in the case of the PFU assay, possibly operator dependent. Methods/Findings A rapid, optimized, accurate, and reliable technique for titration of measles virus was developed based on the detection of virus infected cells by flow cytometry, single round of infection and titer calculation according to the Poisson's law. The kinetics follow up of the number of infected cells after infection with serial dilutions of a virus allowed estimation of the duration of the replication cycle, and consequently, the optimal infection time. The assay was set up to quantify measles virus, vesicular stomatitis virus (VSV), and human immunodeficiency virus type 1 (HIV-1) using antibody labeling of viral glycoprotein, virus encoded fluorescent reporter protein and an inducible fluorescent-reporter cell line, respectively. Conclusion Overall, performing the assay takes only 24–30 hours for MV strains, 12 hours for VSV, and 52 hours for HIV-1. The step-by-step procedure we have set up can be, in principle, applicable to accurately quantify any virus including lentiviral vectors, provided that a virus encoded gene product can be detected by flow cytometry. PMID:21915289
Viable cell sorting of dinoflagellates by multi-parametric flow cytometry.
USDA-ARS?s Scientific Manuscript database
Electronic cell sorting for isolation and culture of dinoflagellates and other marine eukaryotic phytoplankton was compared to the traditional method of manually picking of cells using a micropipette. Trauma to electronically sorted cells was not a limiting factor as fragile dinoflagellates, such a...
Chen, Junhui; Wei, Dong; Pohnert, Georg
2017-07-19
The green microalga Chromochloris zofingiensis can accumulate significant amounts of valuable carotenoids, mainly natural astaxanthin, a product with applications in functional food, cosmetics, nutraceuticals, and with potential therapeutic value in cardiovascular and neurological diseases. To optimize the production of astaxanthin, it is essential to monitor the content of astaxanthin in algal cells during cultivation. The widely used HPLC (high-performance liquid chromatography) method for quantitative astaxanthin determination is time-consuming and laborious. In the present work, we present a method using flow cytometry (FCM) for in vivo determination of the astaxanthin content and the carotenoid-to-chlorophyll ratio (Car/Chl) in mixotrophic C. zofingiensis . The method is based on the assessment of fluorescent characteristics of cellular pigments. The mean fluorescence intensity (MFI) of living cells was determined by FCM to monitor pigment formation based on the correlation between MFI detected in particular channels (FL1: 533 ± 15 nm; FL2: 585 ± 20 nm; FL3: >670 nm) and pigment content in algal cells. Through correlation and regression analysis, a linear relationship was observed between MFI in FL2 (band-pass filter, emission at 585 nm in FCM) and astaxanthin content (in HPLC) and applied for predicting astaxanthin content. With similar procedures, the relationships between MFI in different channels and Car/Chl ratio in mixotrophic C. zofingiensis were also determined. Car/Chl ratios could be estimated by the ratios of MFI (FL1/FL3, FL2/FL3). FCM is thus a highly efficient and feasible method for rapid estimation of astaxanthin content in the green microalga C. zofingiensis . The rapid FCM method is complementary to the current HPLC method, especially for rapid evaluation and prediction of astaxanthin formation as it is required during the high-throughput culture in the laboratory and mass cultivation in industry.
Chen, Junhui; Pohnert, Georg
2017-01-01
The green microalga Chromochloris zofingiensis can accumulate significant amounts of valuable carotenoids, mainly natural astaxanthin, a product with applications in functional food, cosmetics, nutraceuticals, and with potential therapeutic value in cardiovascular and neurological diseases. To optimize the production of astaxanthin, it is essential to monitor the content of astaxanthin in algal cells during cultivation. The widely used HPLC (high-performance liquid chromatography) method for quantitative astaxanthin determination is time-consuming and laborious. In the present work, we present a method using flow cytometry (FCM) for in vivo determination of the astaxanthin content and the carotenoid-to-chlorophyll ratio (Car/Chl) in mixotrophic C. zofingiensis. The method is based on the assessment of fluorescent characteristics of cellular pigments. The mean fluorescence intensity (MFI) of living cells was determined by FCM to monitor pigment formation based on the correlation between MFI detected in particular channels (FL1: 533 ± 15 nm; FL2: 585 ± 20 nm; FL3: >670 nm) and pigment content in algal cells. Through correlation and regression analysis, a linear relationship was observed between MFI in FL2 (band-pass filter, emission at 585 nm in FCM) and astaxanthin content (in HPLC) and applied for predicting astaxanthin content. With similar procedures, the relationships between MFI in different channels and Car/Chl ratio in mixotrophic C. zofingiensis were also determined. Car/Chl ratios could be estimated by the ratios of MFI (FL1/FL3, FL2/FL3). FCM is thus a highly efficient and feasible method for rapid estimation of astaxanthin content in the green microalga C. zofingiensis. The rapid FCM method is complementary to the current HPLC method, especially for rapid evaluation and prediction of astaxanthin formation as it is required during the high-throughput culture in the laboratory and mass cultivation in industry. PMID:28753934
[Isolation and identification of human periodontal ligament stem cells in vitro].
Shen, Tao; Chang, Hui-jun; Jian, Cong-xiang; Yang, Yan-chun; Zhou, Ji-xiang
2011-02-01
To isolate and identify human periodontal ligament stem cells (PDLSC) by improved methods and assess the characteristics of PDLSC ex vivo. The periodontal ligament cells were obtained from the healthy impacted third molars and teeth extracted for orthodontic purposes and used to isolate PDLSC by limiting dilution assay. PDLSC were cultured and expanded in alpha-MEM supplemented with 10% FBS. Colony-forming assay, immunohistochemistry, flow cytometry, osteogenic and adipogenic induction were used to identify PDLSC. The obtained cells had high colony-forming efficiency and were positive staining for vimentin and negative for pancytokeratin. Flow cytometry revealed that the isolated cells were positive for STRO-1 and CD146 antibodies and most were in the G0/G1 phase of cell cycle. Under specific conditions, they could differentiate to the osteoblast and adipocyte lineages in vitro. Limiting dilution assay is an effective method to isolate PDLSC and the single-cell-derived colonies demonstrate the properties of stem cells in vitro.
Davis, W C; Wyatt, C R; Hamilton, M J; Goff, W L
1992-01-01
Fluorescence flow cytometry was employed to assess the potential of a vital dye, hydroethidine, for use in the detection and monitoring of the viability of hemoparasites in infected erythrocytes, using Babesia bovis as a model parasite. The studies demonstrated that hydroethidine is taken up by B. bovis and metabolically converted to the DNA binding fluorochrome, ethidium. Following uptake of the dye, erythrocytes containing viable parasites were readily distinguished and quantitated. Timed studies with the parasiticidal drug, Ganaseg, showed that it is possible to use the fluorochrome assay to monitor the effects of the drug on the rate of replication and viability of B. bovis in culture. The assay provides a rapid method for evaluation of the in vitro effect of drugs on hemoparasites and for analysis of the effect of various components of the immune response, such as lymphokines, monocyte products, antibodies, and effector cells (T, NK, LAK, ADCC) on the growth and viability of intraerythrocytic parasites.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-24
... in the diagnosis of leukemia and lymphoma and more recently in the detection of minimal residual... chronic lymphocytic leukemia (CLL); (3) Third-party flow cytometry data analysis software; and (4... held February 27, 2013 (77 FR 76051, December 26, 2012). An FDA workshop for acute lymphocytic leukemia...
Evolution of microbiological analytical methods for dairy industry needs
Sohier, Danièle; Pavan, Sonia; Riou, Armelle; Combrisson, Jérôme; Postollec, Florence
2014-01-01
Traditionally, culture-based methods have been used to enumerate microbial populations in dairy products. Recent developments in molecular methods now enable faster and more sensitive analyses than classical microbiology procedures. These molecular tools allow a detailed characterization of cell physiological states and bacterial fitness and thus, offer new perspectives to integration of microbial physiology monitoring to improve industrial processes. This review summarizes the methods described to enumerate and characterize physiological states of technological microbiota in dairy products, and discusses the current deficiencies in relation to the industry’s needs. Recent studies show that Polymerase chain reaction-based methods can successfully be applied to quantify fermenting microbes and probiotics in dairy products. Flow cytometry and omics technologies also show interesting analytical potentialities. However, they still suffer from a lack of validation and standardization for quality control analyses, as reflected by the absence of performance studies and official international standards. PMID:24570675
Evolution of microbiological analytical methods for dairy industry needs.
Sohier, Danièle; Pavan, Sonia; Riou, Armelle; Combrisson, Jérôme; Postollec, Florence
2014-01-01
Traditionally, culture-based methods have been used to enumerate microbial populations in dairy products. Recent developments in molecular methods now enable faster and more sensitive analyses than classical microbiology procedures. These molecular tools allow a detailed characterization of cell physiological states and bacterial fitness and thus, offer new perspectives to integration of microbial physiology monitoring to improve industrial processes. This review summarizes the methods described to enumerate and characterize physiological states of technological microbiota in dairy products, and discusses the current deficiencies in relation to the industry's needs. Recent studies show that Polymerase chain reaction-based methods can successfully be applied to quantify fermenting microbes and probiotics in dairy products. Flow cytometry and omics technologies also show interesting analytical potentialities. However, they still suffer from a lack of validation and standardization for quality control analyses, as reflected by the absence of performance studies and official international standards.
Lu, Mei; Chan, Brian M; Schow, Peter W; Chang, Wesley S; King, Chadwick T
2017-12-01
With current available assay formats using either immobilized protein (ELISA, enzyme-linked immunosorbent assay) or immunostaining of fixed cells for primary monoclonal antibody (mAb) screening, researchers often fail to identify and characterize antibodies that recognize the native conformation of cell-surface antigens. Therefore, screening using live cells has become an integral and important step contributing to the successful identification of therapeutic antibody candidates. Thus the need for developing high-throughput screening (HTS) technologies using live cells has become a major priority for therapeutic mAb discovery and development. We have developed a novel technique called Multiplexed Fluorescent Cell Barcoding (MFCB), a flow cytometry-based method based upon the Fluorescent Cell Barcoding (FCB) technique and the Luminex fluorescent bead array system, but is applicable to high-through mAb screens on live cells. Using this technique in our system, we can simultaneously identify or characterize the antibody-antigen binding of up to nine unique fluorescent labeled cell populations in the time that it would normally take to process a single population. This has significantly reduced the amount of time needed for the identification of potential lead candidates. This new technology enables investigators to conduct large-scale primary hybridoma screens using flow cytometry. This in turn has allowed us to screen antibodies more efficiently than before and streamline identification and characterization of lead molecules. Copyright © 2017 Elsevier B.V. All rights reserved.
Evaluation of intranuclear BrdU detection procedures for use in multicolor flow cytometry*
Rothaeusler, Kristina; Baumgarth, Nicole
2010-01-01
Background Measurement of cell proliferation via BrdU incorporation in combination with multicolor cell surface staining would facilitate studies on cell subsets that require multiple markers for their identification. However, the extent to which the often harsh cell preparation procedures required affect the staining quality of more recently developed fluorescent dyes has not been assessed. Methods Three cell preparation protocols for BrdU measurement were compared for their ability to maintain fluorescent surface staining and scatter parameters of in vivo BrdU-labeled cells by flow cytometry. A 10-color fluorescent panel was developed to test the quality of surface staining following cell treatment and the ability to perform BrdU measurements on even small B lymphocyte subsets. Results All cell preparation procedures affected the quality of fluorescent and/or scatter parameters to varying degrees. Paraformaldehyde / saponin-based procedures preserved sufficient fluorescent surface staining to determine BrdU incorporation rates among all splenic B cell subsets, including B-1a cells, which constitute roughly 0.5% of cells. Turnover rates of B-1a cells were similar to immature B cells and higher than those of the other mature B cell subsets. Conclusion Paraformaldehyde / saponin-based cell preparation procedures facilitate detailed cell turnover studies on small cell subsets in vivo, revealing new functional information on rare cell populations. PMID:16538653
Jokerst, Jesse V.; Floriano, Pierre N.; Christodoulides, Nicolaos; Simmons, Glennon W.; McDevitt, John T.
2010-01-01
Recent humanitarian efforts have led to the widespread release of antiretroviral drugs for the treatment of the more than 33 million HIV afflicted people living in resource-scarce settings. Here, the enumeration of CD4+ T lymphocytes is required to establish the level at which the immune system has been compromised. The gold standard method used in developed countries, based on flow cytometry, though widely accepted and accurate, is precluded from widespread use in resource-scarce settings due to its high expense, high technical requirements, difficulty in operation-maintenance and the lack of portability for these sophisticated laboratory-confined systems. As part of continuing efforts to develop practical diagnostic instrumentation, the integration of semiconductor nanocrystals (quantum dots, QDs) into a portable microfluidic-based lymphocyte capture and detection device is completed. This integrated system is capable of isolating and counting selected lymphocyte sub-populations (CD3+CD4+) from whole blood samples. By combining the unique optical properties of the QDs with the sample handling capabilities and cost effectiveness of novel microfluidic systems, a practical, portable lymphocyte measurement modality that correlates nicely with flow cytometry (R2 = 0.97) has been developed. This QD-based system reduces the optical requirements significantly relative to molecular fluorophores and the mini-CD4 counting device is projected to be suitable for use in both point-of-need and resource-scarce settings. PMID:19023471
Searching for gene flow from cultivated to wild strawberries in Central Europe
Schulze, Juerg; Stoll, Peter; Widmer, Alex; Erhardt, Andreas
2011-01-01
Background and Aims Experimental crosses between the diploid woodland strawberry (Fragaria vesca L.) and the octoploid garden strawberry (F. × ananassa Duch.) can lead to the formation of viable hybrids. However, the extent of such hybrid formation under natural conditions is unknown, but is of fundamental interest and importance in the light of the potential future cultivation of transgenic strawberries. A hybrid survey was therefore conducted in the surroundings of ten farms in Switzerland and southern Germany, where strawberries have been cultivated for at least 10 years and where wild strawberries occur in the close vicinity. Methods In 2007 and 2008, 370 wild F. vesca plants were sampled at natural populations around farms and analysed with microsatellite markers. In 2010, natural populations were revisited and morphological traits of 3050 F. vesca plants were inspected. DNA contents of cell nuclei of morphologically deviating plants were estimated by flow cytometry to identify hybrids. As controls, 50 hybrid plants from interspecific hand-crosses were analysed using microsatellite analysis and DNA contents of cell nuclei were estimated by flow cytometry. Key Results None of the wild samples collected in 2007 and 2008 contained F. × ananassa microsatellite markers, while all hybrids from hand-crosses clearly contained markers of both parent species. Morphological inspection of wild populations carried out in 2010 and subsequent flow cytometry of ten morphologically deviating plants revealed no hybrids. Conclusions Hybrid formation or hybrid establishment in natural populations in the survey area is at best a rare event. PMID:21307039
Zaer, F S; Braylan, R C; Zander, D S; Iturraspe, J A; Almasri, N M
1998-06-01
Primary mucosa associated lymphoid tissue (MALT) lymphomas are rare neoplasms that seem to have a better prognosis than nodal lymphomas. Morphologic diagnosis of these lesions may be difficult because of features that overlap with those of benign lymphoid infiltrates. In this study, we assessed the contribution of multi-parametric flow cytometry in demonstrating clonality and further characterizing pulmonary MALT lymphomas. Based on a clinical or pathologic suspicion of MALT-lymphoma, 3 transbronchial biopsies, 4 fine needle aspirates, 1 core needle biopsy, and 13 wedge excisions of lung were submitted fresh (unfixed) to our laboratory for evaluation. Among the 13 cases diagnosed as MALT lymphomas, B-cell monoclonality was established by identifying expression of a single immunoglobulin light chain on CD20 or CD19-positive cells in 12 cases. One case lacked expression of both light chains on B-cells. Of 11 lymphoma cases in which CD5 and CD10 surface antigens were assessed, no cases expressed CD10, and 1 case demonstrated weak CD5 expression. Nine of 10 cases studied were diploid and 1 case was hyperdiploid. All of the lymphomas displayed low (< or = 3%) S-phase fractions consistent with low grade processes. In 10 patients with short follow-up, none died of their disease and the majority had no evidence of lymphoma dissemination. In seven of the remaining eight cases, B-cells were polyclonal consistent with reactive processes. In one morphologically reactive case, flow cytometric analysis was unsuccessful because of poor cell viability. The pulmonary MALT lymphomas in this study represent a group of B-cell tumors with distinctive morphologic, immunophenotypic, and cell kinetic characteristics. Multi-parametric flow cytometry is useful for confirming B-cell monoclonality and illustrating an antigenic profile compatible with this diagnosis. Flow cytometry can be particularly helpful when working with small biopsies and cytologic samples with limited diagnostic material and may abrogate the need for more aggressive surgical procedures.
Masks in Imaging Flow Cytometry
Dominical, Venina; Samsel, Leigh; McCoy, J. Philip
2016-01-01
Data analysis in imaging flow cytometry incorporates elements of flow cytometry together with other aspects of morphological analysis of images. A crucial early step in this analysis is the creation of a mask to distinguish the portion of the image upon which further examination of specified features can be performed. Default masks are provided by the manufacturer of the imaging flow cytometer but additional custom masks can be created by the individual user for specific applications. Flawed or inaccurate masks can have a substantial negative impact on the overall analysis of a sample, thus great care must be taken to ensure the accuracy of masks. Here we discuss various types of masks and cite examples of their use. Furthermore we provide our insight for how to approach selecting and assessing the optimal mask for a specific analysis. PMID:27461256
RchyOptimyx: Cellular Hierarchy Optimization for Flow Cytometry
Aghaeepour, Nima; Jalali, Adrin; O’Neill, Kieran; Chattopadhyay, Pratip K.; Roederer, Mario; Hoos, Holger H.; Brinkman, Ryan R.
2013-01-01
Analysis of high-dimensional flow cytometry datasets can reveal novel cell populations with poorly understood biology. Following discovery, characterization of these populations in terms of the critical markers involved is an important step, as this can help to both better understand the biology of these populations and aid in designing simpler marker panels to identify them on simpler instruments and with fewer reagents (i.e., in resource poor or highly regulated clinical settings). However, current tools to design panels based on the biological characteristics of the target cell populations work exclusively based on technical parameters (e.g., instrument configurations, spectral overlap, and reagent availability). To address this shortcoming, we developed RchyOptimyx (cellular hieraRCHY OPTIMization), a computational tool that constructs cellular hierarchies by combining automated gating with dynamic programming and graph theory to provide the best gating strategies to identify a target population to a desired level of purity or correlation with a clinical outcome, using the simplest possible marker panels. RchyOptimyx can assess and graphically present the trade-offs between marker choice and population specificity in high-dimensional flow or mass cytometry datasets. We present three proof-of-concept use cases for RchyOptimyx that involve 1) designing a panel of surface markers for identification of rare populations that are primarily characterized using their intracellular signature; 2) simplifying the gating strategy for identification of a target cell population; 3) identification of a non-redundant marker set to identify a target cell population. PMID:23044634
Flow cytometric single cell analysis reveals heterogeneity between adipose depots
Boumelhem, Badwi B.; Assinder, Stephen J.; Bell-Anderson, Kim S.; Fraser, Stuart T.
2017-01-01
ABSTRACT Understanding adipose tissue heterogeneity is hindered by the paucity of methods to analyze mature adipocytes at the single cell level. Here, we report a system for analyzing live adipocytes from different adipose depots in the adult mouse. Single cell suspensions of buoyant adipocytes were separated from the stromal vascular fraction and analyzed by flow cytometry. Compared to other lipophilic dyes, Nile Red uptake effectively distinguished adipocyte populations. Nile Red fluorescence increased with adipocyte size and granularity and could be combined with MitoTracker® Deep Red or fluorescent antibody labeling to further dissect adipose populations. Epicardial adipocytes exhibited the least mitochondrial membrane depolarization and highest fatty-acid translocase CD36 surface expression. In contrast, brown adipocytes showed low surface CD36 expression. Pregnancy resulted in reduced mitochondrial membrane depolarisation and increased CD36 surface expression in brown and epicardial adipocyte populations respectively. Our protocol revealed unreported heterogeneity between adipose depots and highlights the utility of flow cytometry for screening adipocytes at the single cell level. PMID:28453382
Zwartz, Gordon J.; Chigaev, Alexandre; Foutz, Terry D.; Edwards, Bruce; Sklar, Larry A.
2013-01-01
Extracellular hydrodynamic forces may be transmitted to the interior of cells through the alteration of integrin conformation and affinity. Integrin activation regulates leukocyte recruitment, cell activation, and transmigration. The cellular and molecular mechanisms for integrin activation are not precisely known, although intracellular calcium signaling is involved. Flow cytometry offers a versatile way to study intracellular calcium signaling in real-time. We report a novel method to generate defined shear by using a miniature Couette. Testing involved measuring shear induced intracellular calcium signals of human monoblastoid U937 cells in suspension. The Couette was connected externally to a flow cytometer and pressurized at 6 PSI (4.1 N/m2). Cells were subjected to well-defined shear between 0 and 1000 s−1 and delivered continuously within 10 s to a FACScan at 1 μl/s. Intracellular calcium levels and the percentage of cells activated increased as shear increased in duration and intensity. PMID:22045643
Monitoring circulating prostate tumor cells after tumor resection by in vivo flow cytometry
NASA Astrophysics Data System (ADS)
Ding, Nan; Zhu, Xi; Xie, Chengying; Wei, Dan; Yang, Zhangru; Suo, Yuanzhen; Wei, Xunbin
2018-02-01
Prostate cancer has already become the biggest threat among all cancer types for male people and many people died because of its bone metastases. Circulating tumor cells (CTCs) can be used as early metastasis marker so that the detection of CTCs in blood is meaningful for early diagnosis and treatment. However, the relationship between these therapies and metastasis has not been fully clarified yet. Hence, we built PC3 subcutaneous tumor model and developed in vivo flow cytometer (IVFC) platform to record the dynamics of CTC before and after tumor resection. We found out that tumor resection can reduce CTC quantities instantaneously while having a good control of metastasis. CTC re-occurred 7 days after surgery, which might be correlated with early disseminated and deposited tumors. In conclusion, in vivo flow cytometry (IVFC) is capable of detecting CTC dynamics in prostate subcutaneous tumor model and this method could facilitate further research about relationship between other cancer therapies and circulating tumor cells.