Sample records for flow imaging cfi

  1. Shear Wave Wavefront Mapping Using Ultrasound Color Flow Imaging.

    PubMed

    Yamakoshi, Yoshiki; Kasahara, Toshihiro; Iijima, Tomohiro; Yuminaka, Yasushi

    2015-10-01

    A wavefront reconstruction method for a continuous shear wave is proposed. The method uses ultrasound color flow imaging (CFI) to detect the shear wave's wavefront. When the shear wave vibration frequency satisfies the required frequency condition and the displacement amplitude satisfies the displacement amplitude condition, zero and maximum flow velocities appear at the shear wave vibration phases of zero and π rad, respectively. These specific flow velocities produce the shear wave's wavefront map in CFI. An important feature of this method is that the shear wave propagation is observed in real time without addition of extra functions to the ultrasound imaging system. The experiments are performed using a 6.5 MHz CFI system. The shear wave is excited by a multilayer piezoelectric actuator. In a phantom experiment, the shear wave velocities estimated using the proposed method and those estimated using a system based on displacement measurement show good agreement. © The Author(s) 2015.

  2. Color and Vector Flow Imaging in Parallel Ultrasound With Sub-Nyquist Sampling.

    PubMed

    Madiena, Craig; Faurie, Julia; Poree, Jonathan; Garcia, Damien; Garcia, Damien; Madiena, Craig; Faurie, Julia; Poree, Jonathan

    2018-05-01

    RF acquisition with a high-performance multichannel ultrasound system generates massive data sets in short periods of time, especially in "ultrafast" ultrasound when digital receive beamforming is required. Sampling at a rate four times the carrier frequency is the standard procedure since this rule complies with the Nyquist-Shannon sampling theorem and simplifies quadrature sampling. Bandpass sampling (or undersampling) outputs a bandpass signal at a rate lower than the maximal frequency without harmful aliasing. Advantages over Nyquist sampling are reduced storage volumes and data workflow, and simplified digital signal processing tasks. We used RF undersampling in color flow imaging (CFI) and vector flow imaging (VFI) to decrease data volume significantly (factor of 3 to 13 in our configurations). CFI and VFI with Nyquist and sub-Nyquist samplings were compared in vitro and in vivo. The estimate errors due to undersampling were small or marginal, which illustrates that Doppler and vector Doppler images can be correctly computed with a drastically reduced amount of RF samples. Undersampling can be a method of choice in CFI and VFI to avoid information overload and reduce data transfer and storage.

  3. A GPU-Parallelized Eigen-Based Clutter Filter Framework for Ultrasound Color Flow Imaging.

    PubMed

    Chee, Adrian J Y; Yiu, Billy Y S; Yu, Alfred C H

    2017-01-01

    Eigen-filters with attenuation response adapted to clutter statistics in color flow imaging (CFI) have shown improved flow detection sensitivity in the presence of tissue motion. Nevertheless, its practical adoption in clinical use is not straightforward due to the high computational cost for solving eigendecompositions. Here, we provide a pedagogical description of how a real-time computing framework for eigen-based clutter filtering can be developed through a single-instruction, multiple data (SIMD) computing approach that can be implemented on a graphical processing unit (GPU). Emphasis is placed on the single-ensemble-based eigen-filtering approach (Hankel singular value decomposition), since it is algorithmically compatible with GPU-based SIMD computing. The key algebraic principles and the corresponding SIMD algorithm are explained, and annotations on how such algorithm can be rationally implemented on the GPU are presented. Real-time efficacy of our framework was experimentally investigated on a single GPU device (GTX Titan X), and the computing throughput for varying scan depths and slow-time ensemble lengths was studied. Using our eigen-processing framework, real-time video-range throughput (24 frames/s) can be attained for CFI frames with full view in azimuth direction (128 scanlines), up to a scan depth of 5 cm ( λ pixel axial spacing) for slow-time ensemble length of 16 samples. The corresponding CFI image frames, with respect to the ones derived from non-adaptive polynomial regression clutter filtering, yielded enhanced flow detection sensitivity in vivo, as demonstrated in a carotid imaging case example. These findings indicate that the GPU-enabled eigen-based clutter filtering can improve CFI flow detection performance in real time.

  4. Spiral Flow Phantom for Ultrasound Flow Imaging Experimentation.

    PubMed

    Yiu, Billy Y S; Yu, Alfred C H

    2017-12-01

    As new ultrasound flow imaging methods are being developed, there is a growing need to devise appropriate flow phantoms that can holistically assess the accuracy of the derived flow estimates. In this paper, we present a novel spiral flow phantom design whose Archimedean spiral lumen naturally gives rise to multi-directional flow over all possible angles (i.e., from 0° to 360°). Developed using lost-core casting principles, the phantom geometry comprised a three-loop spiral (4-mm diameter and 5-mm pitch), and it was set to operate in steady flow mode (3 mL/s flow rate). After characterizing the flow pattern within the spiral vessel using computational fluid dynamics (CFD) simulations, the phantom was applied to evaluate the performance of color flow imaging (CFI) and high-frame-rate vector flow imaging. Significant spurious coloring artifacts were found when using CFI to visualize flow in the spiral phantom. In contrast, using vector flow imaging (least-squares multi-angle Doppler based on a three-transmit and three-receive configuration), we observed consistent depiction of flow velocity magnitude and direction within the spiral vessel lumen. The spiral flow phantom was also found to be a useful tool in facilitating demonstration of dynamic flow visualization based on vector projectile imaging. Overall, these results demonstrate the spiral flow phantom's practical value in analyzing the efficacy of ultrasound flow estimation methods.

  5. Colour flow and motion imaging.

    PubMed

    Evans, D H

    2010-01-01

    Colour flow imaging (CFI) is an ultrasound imaging technique whereby colour-coded maps of tissue velocity are superimposed on grey-scale pulse-echo images of tissue anatomy. The most widespread use of the method is to image the movement of blood through arteries and veins, but it may also be used to image the motion of solid tissue. The production of velocity information is technically more demanding than the production of the anatomical information, partly because the target of interest is often blood, which backscatters significantly less power than solid tissues, and partly because several transmit-receive cycles are necessary for each velocity estimate. This review first describes the various components of basic CFI systems necessary to generate the velocity information and to combine it with anatomical information. It then describes a number of variations on the basic autocorrelation technique, including cross-correlation-based techniques, power Doppler, Doppler tissue imaging, and three-dimensional (3D) Doppler imaging. Finally, a number of limitations of current techniques and some potential solutions are reviewed.

  6. The Value of Visa-Score and Colour Flow Imaging in the Follow-Up of Non-Athletes Operated for Jumpers Knee.

    PubMed

    Salvesen, Eirik S; Holen, Ketil J

    2016-12-01

    The objective of this study was to assess if the Victorian Institute of Sport Assessment (VISA) questionnaire was suitable in the evaluation of patients from a mixed population with normal levels of sports activity, and if neovascularization of the patellar tendon demonstrated by color flow imaging (CFI) was more frequent in patients with lasting symptoms after surgical treatment for jumpers knee (JK). This study was conducted at St. Olavs Hospital, University Hospital of Trondheim, Norway, and included 21 men and 18 women who were operated for JK. Symptoms were assessed using the Knee Injury and Osteoarthritis Outcome Score (KOOS) and VISA questionnaires. Clinical and ultrasonographic examinations of the knees, including CFI, were done at a mean follow-up duration of 82 (range, 16-136) months after surgery. Patients with positive CFI also had significantly lower KOOS scores, whereas the total VISA-P (Victorian Institute of Sport Assessment - Patella) score showed no association. Patients with a positive clinical examination had significantly more frequent positive CFI findings than did patients with negative examinations. The operated patellar tendon was significantly thicker and had more frequent hypoechoic signal in the proximal part than the contralateral unoperated tendon. The post-operative VISA-P score seems less valuable in the evaluation of patients from a mixed population with normal levels of sports activity. CFI may be a valuable diagnostic tool in the evaluation of patients operated for JK.

  7. Relativistic centrifugal instability

    NASA Astrophysics Data System (ADS)

    Gourgouliatos, Konstantinos N.; Komissarov, Serguei S.

    2018-03-01

    Near the central engine, many astrophysical jets are expected to rotate about their axis. Further out they are expected to go through the processes of reconfinement and recollimation. In both these cases, the flow streams along a concave surface and hence, it is subject to the centrifugal force. It is well known that such flows may experience the centrifugal instability (CFI), to which there are many laboratory examples. The recent computer simulations of relativistic jets from active galactic nuclei undergoing the process of reconfinement show that in such jets CFI may dominate over the Kelvin-Helmholtz instability associated with velocity shear (Gourgouliatos & Komissarov). In this letter, we generalize the Rayleigh criterion for CFI in rotating fluids to relativistic flows using a heuristic analysis. We also present the results of computer simulations which support our analytic criterion for the case of an interface separating two uniformly rotating cylindrical flows. We discuss the difference between CFI and the Rayleigh-Taylor instability in flows with curved streamlines.

  8. Quantitative Doppler Analysis Using Conventional Color Flow Imaging Acquisitions.

    PubMed

    Karabiyik, Yucel; Ekroll, Ingvild Kinn; Eik-Nes, Sturla H; Lovstakken, Lasse

    2018-05-01

    Interleaved acquisitions used in conventional triplex mode result in a tradeoff between the frame rate and the quality of velocity estimates. On the other hand, workflow becomes inefficient when the user has to switch between different modes, and measurement variability is increased. This paper investigates the use of power spectral Capon estimator in quantitative Doppler analysis using data acquired with conventional color flow imaging (CFI) schemes. To preserve the number of samples used for velocity estimation, only spatial averaging was utilized, and clutter rejection was performed after spectral estimation. The resulting velocity spectra were evaluated in terms of spectral width using a recently proposed spectral envelope estimator. The spectral envelopes were also used for Doppler index calculations using in vivo and string phantom acquisitions. In vivo results demonstrated that the Capon estimator can provide spectral estimates with sufficient quality for quantitative analysis using packet-based CFI acquisitions. The calculated Doppler indices were similar to the values calculated using spectrograms estimated on a commercial ultrasound scanner.

  9. Shear Wave Imaging of Breast Tissue by Color Doppler Shear Wave Elastography.

    PubMed

    Yamakoshi, Yoshiki; Nakajima, Takahito; Kasahara, Toshihiro; Yamazaki, Mayuko; Koda, Ren; Sunaguchi, Naoki

    2017-02-01

    Shear wave elastography is a distinctive method to access the viscoelastic characteristic of the soft tissue that is difficult to obtain by other imaging modalities. This paper proposes a novel shear wave elastography [color Doppler shear wave imaging (CD SWI)] for breast tissue. Continuous shear wave is produced by a small lightweight actuator, which is attached to the tissue surface. Shear wave wavefront that propagates in tissue is reconstructed as a binary pattern that consists of zero and the maximum flow velocities on color flow image (CFI). Neither any modifications of the ultrasound color flow imaging instrument nor a high frame rate ultrasound imaging instrument is required to obtain the shear wave wavefront map. However, two conditions of shear wave displacement amplitude and shear wave frequency are needed to obtain the map. However, these conditions are not severe restrictions in breast imaging. This is because the minimum displacement amplitude is [Formula: see text] for an ultrasonic wave frequency of 12 MHz and the shear wave frequency is available from several frequencies suited for breast imaging. Fourier analysis along time axis suppresses clutter noise in CFI. A directional filter extracts shear wave, which propagates in the forward direction. Several maps, such as shear wave phase, velocity, and propagation maps, are reconstructed by CD SWI. The accuracy of shear wave velocity measurement is evaluated for homogeneous agar gel phantom by comparing with the acoustic radiation force impulse method. The experimental results for breast tissue are shown for a shear wave frequency of 296.6 Hz.

  10. Ultrasound tagged near infrared spectroscopy does not detect hyperventilation-induced reduction in cerebral blood flow.

    PubMed

    Lund, Anton; Secher, Niels H; Hirasawa, Ai; Ogoh, Shigehiko; Hashimoto, Takeshi; Schytz, Henrik W; Ashina, Messoud; Sørensen, Henrik

    2016-01-01

    Continuous non-invasive monitoring of cerebral blood flow (CBF) may be important during anaesthesia and several options are available. We evaluated the CerOx monitor that employs ultrasound tagged near infrared spectroscopy to estimate changes in a CBF index (CFI). Seven healthy males (age 21-26 years) hyperventilated and were administered phenylephrine to increase mean arterial pressure by 20-30 mmHg. Frontal lobe tissue oxygenation (ScO2) and CFI were obtained using the CerOx and mean blood flow velocity in the middle cerebral artery (MCAv mean) was determined by transcranial Doppler. Blood flow in the internal and external carotid artery (ICAf and ECAf) was determined using duplex ultrasonography and forehead skin blood flow (SkBF) and oxygenation (S skin O2) by laser Doppler and white light spectroscopy. During hyperventilation MCAv mean and ICAf decreased by 44% (median; interquartile range 40-49; p = 0.016) and 46% (40-53; p = 0.03), respectively. Conversely, CFI increased by 9% (2-31; p = 0.016), while no significant change was observed in ScO2. SkBF increased by 19% (9-53; p = 0.016) and S skin O2 by 6% (1-7; p = 0.047), although ECAf was unchanged. Administration of phenylephrine was not associated with any changes in MCAv mean, ICAf, ECAf, ScO2, SkBF, S skin O2, or CFI. The CerOx was able to detect a stable CBF during administration of phenylephrine. However, during hyperventilation MCAv mean and ICAf decreased while CFI increased, likely due to an increase in superficial tissue oxygenation. Thus, CFI does not provide an unbiased evaluation of changes in CBF.

  11. Three-dimensional assessment of curvature, torsion, and canal flare index of the humerus of skeletally mature nonchondrodystrophic dogs.

    PubMed

    Smith, Emily J; Marcellin-Little, Denis J; Harrysson, Ola L A; Griffith, Emily H

    2017-10-01

    OBJECTIVE To assess 3-D geometry of the humerus of dogs and determine whether the craniocaudal canal flare index (CFI) is associated with specific geometric features. SAMPLE CT images (n = 40) and radiographs (38) for 2 groups of skeletally mature nonchondrodystrophic dogs. PROCEDURES General dimensions (length, CFI, cortical thickness, and humeral head offset), curvature (shaft, humeral head, and glenoid cavity), version (humeral head and greater tubercle), and torsion were evaluated on CT images. Dogs were allocated into 3 groups on the basis of the craniocaudal CFI, and results were compared among these 3 groups. The CT measurements were compared with radiographic measurements obtained for another group of dogs. RESULTS Mean ± SD humeral head version was -75.9 ± 9.6° (range, -100.7° to -59.4°). Mean mechanical lateral distal humeral angle, mechanical caudal proximal humeral angle, and mechanical cranial distal humeral angle were 89.5 ± 3.5°, 50.2 ± 4.5°, and 72.9 ± 7.8°, respectively, and did not differ from corresponding radiographic measurements. Mean humeral curvature was 20.4 ± 4.4° (range, 9.6° to 30.5°). Mean craniocaudal CFI was 1.74 ± 0.18 (range, 1.37 to 2.10). Dogs with a high craniocaudal CFI had thicker cranial and medial cortices than dogs with a low craniocaudal CFI. Increased body weight was associated with a lower craniocaudal CFI. Radiographic and CT measurements of craniocaudal CFI and curvature differed significantly. CONCLUSIONS AND CLINICAL RELEVANCE CT-based 3-D reconstructions allowed the assessment of shaft angulation, torsion, and CFI. Radiographic and CT measurements of shaft curvature and CFI may differ.

  12. Comparison of PLIF and CFD Results for the Orion CEV RCS Jets

    NASA Technical Reports Server (NTRS)

    Ivey, Christopher B.; Danehy, Paul M.; Bathel, Brett F.; Dyakonov, Artem A.; Inman, Jennifer A.; Jones, Stephen B.

    2011-01-01

    Nitric-oxide planar laser-induced fluorescence (NO PLIF) was used to visualize and measure centerline streamwise velocity of the Orion Crew Exploration Vehicle (CEV) Reaction Control System (RCS) Jets at NASA Langley Research Center's 31-Inch Mach 10 Air wind tunnel. Fluorescence flow visualizations of pitch, roll, and yaw RCS jets were obtained using different plenum pressures and wind tunnel operating stagnation pressures. For two yaw RCS jet test cases, the PLIF visualizations were compared to computational flow imaging (CFI) images based on Langley Aerothermal Upwind Relaxation Algorithm (LAURA) computational fluid dynamics (CFD) simulations of the flowfield. For the same test cases, the streamwise velocity measurements were compared to CFD. The CFD solution, while showing some unphysical artifacts, generally agree with the experimental measurements.

  13. Direct Geolocation of Satellite Images with the EO-CFI Libraries

    NASA Astrophysics Data System (ADS)

    de Miguel, Eduardo; Prado, Elena; Estebanez, Monica; Martin, Ana I.; Gonzalez, Malena

    2016-08-01

    The INTA Remote Sensing Laboratory has implemented a tool for the direct geolocation of satellite images. The core of the tool is a C code based on the "Earth Observation Mission CFI SW" from ESA. The tool accepts different types of inputs for satellite attitude (euler angles, quaternions, default attitude models). Satellite position can be provided either in ECEF or ECI coordinates. The line of sight of each individual detector is imported from an external file or is generated by the tool from camera parameters. Global DEM ACE2 is used to define ground intersection of the LOS.The tool has been already tailored for georeferencing images from the forthcoming Spanish Earth Observation mission SEOSat/Ingenio, and for the camera APIS onboard the INTA cubesat OPTOS. The next step is to configure it for the geolocation of Sentinel 2 L1b images.The tool has been internally validated by different means. This validation shows that the tool is suitable for georeferencing images from high spatial resolution missions. As part of the validation efforts, a code for simulating orbital info for LEO missions using EO-CFI has been produced.

  14. Computational modeling of magnetic particle margination within blood flow through LAMMPS

    NASA Astrophysics Data System (ADS)

    Ye, Huilin; Shen, Zhiqiang; Li, Ying

    2017-11-01

    We develop a multiscale and multiphysics computational method to investigate the transport of magnetic particles as drug carriers in blood flow under influence of hydrodynamic interaction and external magnetic field. A hybrid coupling method is proposed to handle red blood cell (RBC)-fluid interface (CFI) and magnetic particle-fluid interface (PFI), respectively. Immersed boundary method (IBM)-based velocity coupling is used to account for CFI, which is validated by tank-treading and tumbling behaviors of a single RBC in simple shear flow. While PFI is captured by IBM-based force coupling, which is verified through movement of a single magnetic particle under non-uniform external magnetic field and breakup of a magnetic chain in rotating magnetic field. These two components are seamlessly integrated within the LAMMPS framework, which is a highly parallelized molecular dynamics solver. In addition, we also implement a parallelized lattice Boltzmann simulator within LAMMPS to handle the fluid flow simulation. Based on the proposed method, we explore the margination behaviors of magnetic particles and magnetic chains within blood flow. We find that the external magnetic field can be used to guide the motion of these magnetic materials and promote their margination to the vascular wall region. Moreover, the scaling performance and speedup test further confirm the high efficiency and robustness of proposed computational method. Therefore, it provides an efficient way to simulate the transport of nanoparticle-based drug carriers within blood flow in a large scale. The simulation results can be applied in the design of efficient drug delivery vehicles that optimally accumulate within diseased tissue, thus providing better imaging sensitivity, therapeutic efficacy and lower toxicity.

  15. Cell-based flavivirus infection (CFI) assay for the evaluation of dengue antiviral candidates using high-content imaging.

    PubMed

    Tan, Kah Hin; Ki, Kitti Chan Wing; Watanabe, Satoru; Vasudevan, Subhash G; Krishnan, Manoj

    2014-01-01

    Large-scale screening of antiviral compounds that target dengue virus life cycle requires a robust cell-based assay that is rapid, easy to conduct, and sensitive enough to be able to assess viral infectivity and cell viability so that antiviral efficacy can be measured. In this chapter we describe a method that uses high-content imaging to evaluate the in vitro antiviral efficacy in a modification to the cell-based flavivirus immunodetection (CFI) assay that was described previously in Wang et al. (Antimicrob Agents Chemother 53(5):1823-1831, 2009).

  16. Improving the cold flow properties of biodiesel with synthetic branched diester additives

    USDA-ARS?s Scientific Manuscript database

    A technical disadvantage of biodiesel relative to petroleum diesel fuel is inferior cold flow properties. One of many methodologies to address this deficiency is employment of cold flow improver (CFI) additives. Generally composed of low-molecular weight copolymers, CFIs originally developed for pet...

  17. Investigating operation at geometrically unconventional intersections.

    DOT National Transportation Integrated Search

    2014-08-01

    This report documents the development of decision assistance curves (DAC) for unconventional intersections, particularly : median U-turns (MUT), continuous flow intersections (CFI), and jughandles. The operational measure of effectiveness : such as d...

  18. 76 FR 56413 - Building Energy Codes Cost Analysis

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-13

    ... the by-zone housing starts of Table 2. \\7\\ See http://rredc.nrel.gov/solar/old_data/nsrdb/tmy2... as an alternative investment rate. Thus the present value, (PV) of a cash flow in year Y (CFy) is...

  19. Development of performance matrices for evaluating innovative intersections and interchanges.

    DOT National Transportation Integrated Search

    2015-09-01

    Innovative intersections and interchanges, primarily Continuous Flow Intersection (CFI) and Diverging Diamond : Interchange (DDI), have seen an increase in numbers in the State of Utah over the past several years, making Utah a : leader in the countr...

  20. Selected configuration tradeoffs of contour optical instruments

    NASA Astrophysics Data System (ADS)

    Warren, J.; Strohbehn, K.; Murchie, S.; Fort, D.; Reynolds, E.; Heyler, G.; Peacock, K.; Boldt, J.; Darlington, E.; Hayes, J.; Henshaw, R.; Izenberg, N.; Kardian, C.; Lees, J.; Lohr, D.; Mehoke, D.; Schaefer, E.; Sholar, T.; Spisz, T.; Willey, C.; Veverka, J.; Bell, J.; Cochran, A.

    2003-01-01

    The Comet Nucleus Tour (CONTOUR) is a low-cost NASA Discovery mission designed to conduct three close flybys of comet nuclei. Selected configuration tradeoffs conducted to balance science requirements with low mission cost are reviewed. The tradeoffs discussed focus on the optical instruments and related spacecraft considerations. Two instruments are under development. The CONTOUR Forward Imager (CFI) is designed to perform optical navigation, moderate resolution nucleus/jet imaging, and imaging of faint molecular emission bands in the coma. The CONTOUR Remote Imager and Spectrometer (CRISP) is designed to obtain high-resolution multispectral images of the nucleus, conduct spectral mapping of the nucleus surface, and provide a backup optical navigation capability. Tradeoffs discussed are: (1) the impact on the optical instruments of not using reaction wheels on the spacecraft, (2) the improved performance and simplification gained by implementing a dedicated star tracker instead of including this function in CFI, (3) the improved flexibility and robustness of switching to a low frame rate tracker for CRISP, (4) the improved performance and simplification of replacing a visible imaging spectrometer by enhanced multispectral imaging in CRISP, and (5) the impact on spacecraft resources of these and other tradeoffs.

  1. The Development of the DSM-5 Cultural Formulation Interview-Fidelity Instrument (CFI-FI): A Pilot Study

    PubMed Central

    Aggarwal, Neil Krishan; Glass, Andrew; Tirado, Amilcar; Boiler, Marit; Nicasio, Andel; Alegría, Margarita; Wall, Melanie; Lewis-Fernández, Roberto

    2015-01-01

    This paper reports on the development of the Cultural Formulation Interview-Fidelity Instrument (CFI-FI) which assesses clinician fidelity to the DSM-5 Cultural Formulation Interview (CFI). The CFI consists of a manualized set of standard questions that can precede every psychiatric evaluation. It is based on the DSM-IV Outline for Cultural Formulation, the cross-cultural assessment with the most evidence in psychiatric training. Using the New York sample of the DSM-5 CFI field trial, two independent raters created and finalized items for the CFI-FI based on six audio-taped and transcribed interviews. The raters then used the final CFI-FI to rate the remaining 23 interviews. Inter-rater reliability ranged from .73 to 1 for adherence items and .52 to 1 for competence items. The development of the CFI-FI can help researchers and administrators determine whether the CFI has been implemented with fidelity, permitting future intervention research. PMID:25130248

  2. Culture in la clínica: Evaluating the utility of the Cultural Formulation Interview (CFI) in a Mexican outpatient setting.

    PubMed

    Ramírez Stege, Alyssa M; Yarris, Kristin Elizabeth

    2017-08-01

    While the classification of psychiatric disorders has been critiqued for failing to adequately account for culture, the inclusion of the Cultural Formulation Interview (CFI) in the DSM-5 has been viewed as a promising development for the inclusion of cultural factors in diagnosis and treatment of mental illness. In this study, we assess the appropriateness, acceptability, and clinical utility of the CFI among outpatients in a Mexican psychiatric hospital. Our assessment included observations of psychiatric residents' application of the CFI with 19 patients during routine outpatient visits, along with pre- and post-CFI interviews to determine providers' and patients' views of the CFI. The CFI was generally well received by providers and patients, viewed as a way of building trust and increasing providers' understanding of contextual factors influencing mental illness, such as social support. However, the CFI questions specifically related to "culture" were of limited effect and both patients and providers did not view them as useful. We discuss implications for the clinical assessment of cultural factors influencing mental health and illness and for the incorporation of the CFI in Mexican clinical settings.

  3. A monoclonal antibody targeting amyloid β (Aβ) restores complement factor I bioactivity: Potential implications in age-related macular degeneration and Alzheimer's disease.

    PubMed

    Lashkari, Kameran; Teague, Gianna; Chen, Hong; Lin, Yong-Qing; Kumar, Sanjay; McLaughlin, Megan M; López, Francisco J

    2018-01-01

    Activation of the alternative complement cascade has been implicated in the pathogenesis of age related macular degeneration (AMD) and Alzheimer's disease (AD). Amyloid β (Aβ), a component of drusen, may promote complement activation by inhibiting CFI bioactivity. We determined whether Aβ reduced CFI bioactivity and whether antibodies against Aβ including a monoclonal antibody, GSK933776 could restore CFI bioactivity. We also measured CFI bioactivity in plasma of subjects with AMD and AD. In support of the GSK933776 development program in AMD (geographic atrophy), we developed a quantitative assay to measure CFI bioactivity based on its ability to cleave C3b to iC3b, and repeated it in presence or absence of Aβ and anti-Aβ antibodies. Using this assay, we measured CFI bioactivity in plasma of 194 subjects with AMD, and in samples from subjects with AD that had been treated with GSK933776 as part of the GSK933776 development program in AD. Aβ reduced the CFI bioactivity by 5-fold and pre-incubation with GSK933776 restored CFI bioactivity. In subjects with AMD, plasma CFI levels and bioactivity were not significantly different from non-AMD controls. However, we detected a positive linear trend, suggesting increasing activity with disease severity. In subjects with AD, we observed a 10% and 27% increase in overall CFI bioactivity after treatment with GSK933776 during the second and third dose. Our studies indicate that CFI enzymatic activity can be inhibited by Aβ and be altered in proinflammatory diseases such as AMD and AD, in which deposition of Aβ and activation of the alternative complement cascade are believed to play a key role in the disease process.

  4. The effect of heart rate reduction by ivabradine on collateral function in patients with chronic stable coronary artery disease.

    PubMed

    Gloekler, Steffen; Traupe, Tobias; Stoller, Michael; Schild, Deborah; Steck, Hélène; Khattab, Ahmed; Vogel, Rolf; Seiler, Christian

    2014-01-01

    To evaluate the effect of heart rate reduction by ivabradine on coronary collateral function in patients with chronic stable coronary artery disease (CAD). This was a prospective randomised placebo-controlled monocentre trial in a university hospital setting. 46 patients with chronic stable CAD received placebo (n=23) or ivabradine (n=23) for the duration of 6 months. The main outcome measure was collateral flow index (CFI) as obtained during a 1 min coronary artery balloon occlusion at study inclusion (baseline) and at the 6-month follow-up examination. CFI is the ratio between simultaneously recorded mean coronary occlusive pressure divided by mean aortic pressure both subtracted by mean central venous pressure. During follow-up, heart rate changed by +0.2±7.8 beats/min in the placebo group, and by -8.1±11.6 beats/min in the ivabradine group (p=0.0089). In the placebo group, CFI decreased from 0.140±0.097 at baseline to 0.109±0.067 at follow-up (p=0.12); it increased from 0.107±0.077 at baseline to 0.152±0.090 at follow-up in the ivabradine group (p=0.0461). The difference in CFI between the 6-month follow-up and baseline examination amounted to -0.031±0.090 in the placebo group and to +0.040±0.094 in the ivabradine group (p=0.0113). Heart rate reduction by ivabradine appears to have a positive effect on coronary collateral function in patients with chronic stable CAD. NCT01039389.

  5. Tracking early decline in cognitive function in older individuals at risk for Alzheimer's disease dementia: the Alzheimer's Disease Cooperative Study Cognitive Function Instrument

    PubMed Central

    Amariglio, Rebecca E.; Donohue, Michael C.; Marshall, Gad A.; Rentz, Dorene M.; Salmon, David P.; Ferris, Steven H.; Karantzoulis, Stella; Aisen, Paul S.; Sperling, Reisa A.

    2015-01-01

    Importance Several large-scale Alzheimer's disease (AD) secondary prevention trials have begun to target individuals at the preclinical stage. The success of these trials depends on validated outcome measures that are sensitive to early clinical progression in individuals who are initially asymptomatic. Objective To investigate the utility of the Cognitive Function Instrument (CFI) to track early changes in cognitive function in older individuals without clinical impairment at baseline. Design, Setting, and Participants Longitudinal study over the course of 48 months at participating Alzheimer's Disease Cooperative Study (ADCS) sites. The study included 468 healthy older individuals (Clinical Dementia Rating Scale [CDR] Global = 0, above cut-off on modified Mini-Mental State Exam and Free and Cued Selective Reminding Test) (mean age= 79.4 years ±3.6). All subjects and their study partners completed the Self and Partner CFI annually. Subjects also underwent concurrent annual neuropsychological assessment and apolipoprotein E (APOE) genotyping. Main outcomes and measures Comparison of CFI scores between clinical progressors (Clinical Dementia Rating Scale [CDR] ≥ 0.5) and non-progressors (CDR remained = 0), as well as between APOE ε4 carriers and non-carriers were performed. Correlations of change between the CFI and neuropsychological performance were assessed longitudinally. Results At 48 months, group differences between clinical progressors and non-progressors were significant for CFI Self, CFI Partner, and CFI Self+Partner total scores. At month 48, APOE ε4 carriers showed greater progression than non-carriers on CFI Partner and CFI Self+Partner scores. Both CFI Self and CFI Partner scores were associated with longitudinal cognitive decline, although findings suggest self report may be more accurate early in the process, whereas accuracy of partner report improves when there is progression to cognitive impairment. Conclusions and Relevance Demonstrating long-term clinical benefit will be critical for the success of recently launched secondary prevention trials. The CFI appears to be a brief, yet informative potential outcome measure that provides insight into functional abilities at the earliest stages of disease. PMID:25706191

  6. Psychometric Properties of a Russian Version of the Cognitive Flexibility Inventory (CFI-R).

    PubMed

    Kurginyan, Sergey S; Osavolyuk, Ekaterina Y

    2018-01-01

    The Cognitive Flexibility Inventory (CFI) is a brief self-report measure of the type of cognitive flexibility (CF) necessary to successfully challenge and restructure maladaptive beliefs with more balanced and adaptive thinking; it is particularly popular for use with English speakers. The CFI has recently been translated into five languages (Chinese, Japanese, Iranian, Turkish, and Russian), although estimates of reliability and validity of these translated versions are scarce. This study reports on the factor structure, internal consistency, reliability, and construct validity of the CFI. We adopted the CFI for a Russian-speaking population, using student sample of 445 first and second-year undergraduates ( M = 18.59 years, SD = 1.19) and found that a two-factor model fitted the data well. However, the structure of the CFI was revised because of some modifications, which were made to the original English to match the Russian equivalents of items originally developed to assess the definite aspect of cognitive flexibility. The CFI-R showed good internal consistency and suitable 7-week test-retest reliability. The construct validity of the Russian version of the CFI was studied by computing correlations with other related measures of CF (Attributional Style Questionnaire), depressive symptoms (Beck Depression Inventory), coping (Ways of Coping (Revised), and rigidity (Tomsk Rigidity Questionnaire). Furthermore, to assess whether the construct validity were affected by psychopathology we examined results for non-clinical and clinical samples, using "known-groups" method. The clinical sample reported lower CF than did the non-clinical sample on the CFI-R's total score and its subscales' scores. Findings in the present study suggest that the psychometric properties of the Russian CFI are comparable to the English original, making it appropriate to research assessment of the type of CF in Russian speaking population.

  7. Structural basis of UGUA recognition by the Nudix protein CFI(m)25 and implications for a regulatory role in mRNA 3' processing.

    PubMed

    Yang, Qin; Gilmartin, Gregory M; Doublié, Sylvie

    2010-06-01

    Human Cleavage Factor Im (CFI(m)) is an essential component of the pre-mRNA 3' processing complex that functions in the regulation of poly(A) site selection through the recognition of UGUA sequences upstream of the poly(A) site. Although the highly conserved 25 kDa subunit (CFI(m)25) of the CFI(m) complex possesses a characteristic alpha/beta/alpha Nudix fold, CFI(m)25 has no detectable hydrolase activity. Here we report the crystal structures of the human CFI(m)25 homodimer in complex with UGUAAA and UUGUAU RNA sequences. CFI(m)25 is the first Nudix protein to be reported to bind RNA in a sequence-specific manner. The UGUA sequence contributes to binding specificity through an intramolecular G:A Watson-Crick/sugar-edge base interaction, an unusual pairing previously found to be involved in the binding specificity of the SAM-III riboswitch. The structures, together with mutational data, suggest a novel mechanism for the simultaneous sequence-specific recognition of two UGUA elements within the pre-mRNA. Furthermore, the mutually exclusive binding of RNA and the signaling molecule Ap(4)A (diadenosine tetraphosphate) by CFI(m)25 suggests a potential role for small molecules in the regulation of mRNA 3' processing.

  8. Central Field Index Versus Visual Field Index for Central Visual Function in Stable Glaucoma.

    PubMed

    Rao, Aparna; Padhy, Debananda; Mudunuri, Harika; Roy, Avik K; Sarangi, Sarada P; Das, Gopinath

    2017-01-01

    To compare the variability of central field index (CFI) versus visual field index (VFI) in stable glaucoma with central fixation involvement. For this retrospective study, we identified multiple visual fields (VFs) of patients with repeatable central fixation involvement on Humphrey VFs (24-2 and 10-2 program) which were stable (clinically and on VFs) over a very short period of 2 to 3 months. The VFI and CFI were calculated as described in earlier reports. We graded the fields as early [mean deviation (MD)>-6 dB], moderate (-6.1 to -12 dB), and severe glaucoma (<-12 dB) based on MD on 24-2 program. The variability of CFI and VFI between visits and across different severity of glaucoma was compared. Relation of the divergence to field indices and clinical parameters were assessed. The intervisit difference for VFI was greater than CFI ranging from -4% to 9% versus -1% to 8% in early (P=0.9), -13% to 18% versus -6% to 17% (P=0.056) in moderate, and -21% to 19% versus -9% to 9% (P<0.001) in severe glaucoma. The CFI within each group had narrower range than VFI with maximum range in severe glaucoma (33% to 95%). The divergence of CFI from VFI started at MD 24-2 beyond (worse) -10 dB. This difference between CFI and VFI was associated significantly with number of points with P<1% on 24-2 (R=80.3%). CFI is less variable than VFI in stable eyes with fixation involvement especially in severe glaucoma indicating need for incorporating CFI calculation for monitoring advanced disease in eyes with central defects.

  9. Feasibility, acceptability and clinical utility of the Cultural Formulation Interview: mixed-methods results from the DSM-5 international field trial.

    PubMed

    Lewis-Fernández, Roberto; Aggarwal, Neil Krishan; Lam, Peter C; Galfalvy, Hanga; Weiss, Mitchell G; Kirmayer, Laurence J; Paralikar, Vasudeo; Deshpande, Smita N; Díaz, Esperanza; Nicasio, Andel V; Boiler, Marit; Alarcón, Renato D; Rohlof, Hans; Groen, Simon; van Dijk, Rob C J; Jadhav, Sushrut; Sarmukaddam, Sanjeev; Ndetei, David; Scalco, Monica Z; Bassiri, Kavoos; Aguilar-Gaxiola, Sergio; Ton, Hendry; Westermeyer, Joseph; Vega-Dienstmaier, Johann M

    2017-04-01

    Background There is a need for clinical tools to identify cultural issues in diagnostic assessment. Aims To assess the feasibility, acceptability and clinical utility of the DSM-5 Cultural Formulation Interview (CFI) in routine clinical practice. Method Mixed-methods evaluation of field trial data from six countries. The CFI was administered to diagnostically diverse psychiatric out-patients during a diagnostic interview. In post-evaluation sessions, patients and clinicians completed debriefing qualitative interviews and Likert-scale questionnaires. The duration of CFI administration and the full diagnostic session were monitored. Results Mixed-methods data from 318 patients and 75 clinicians found the CFI feasible, acceptable and useful. Clinician feasibility ratings were significantly lower than patient ratings and other clinician-assessed outcomes. After administering one CFI, however, clinician feasibility ratings improved significantly and subsequent interviews required less time. Conclusions The CFI was included in DSM-5 as a feasible, acceptable and useful cultural assessment tool. © The Royal College of Psychiatrists 2017.

  10. Careers for Youth. AACE Distinguished Member Series on Career Education.

    ERIC Educational Resources Information Center

    Gnaedinger, John P.

    Four papers by John Gnaedinger focus on the Careers for Youth (CFY) program. "CFY: The Model Program" describes the three phases of development incorporated in CFY: career awareness in grades 6 and 7; career exploration that begins at the end of grade 7; and career preparation that continues through the high school years. The sweat-equity program…

  11. Factors that contribute to the body image concern of female college students.

    PubMed

    Silva, Wanderson Roberto; Dias, Juliana Chioda Ribeiro; Maroco, João; Campos, Juliana Alvares Duarte Bonini

    2015-01-01

    To estimate the contribution of sociodemographic and labor variables and body mass index to body image concern. In order to estimate body image concern, the Body Shape Questionnaire (BSQ) and the Weight Concerns Scale (WCS) were applied. A confirmatory factor analysis of scales was carried out. The reason χ2 by degree of freedom ratio (χ2/df ), Comparative Fit Index (CFI), Normed Fit Index (NFI), and root mean square error of approximation (RMSEA) were used. Convergent validity was assessed through the average variance extracted and composed reliability and the internal consistency through standardized Cronbach's alpha coefficient (α). A structural model was developed, and the body image concern was the second-order main construct. The model appropriation was evaluated based on the goodness-of-fit indices. The z test was used to estimate the significance of trajectories (β) using a 5% significance level. Totally, 595 female college students participated in the study, with a mean age of 20.42 ± 2.44 years. The entire model, with the inclusion of all independent variables, showed unsatisfactory adjustment and was refined. The final model presented a satisfactory adjustment (χ2/df = 5.75; CFI = 0.87; NFI = 0.85; RMSEA = 0.09) with inclusion of medication use because of studies (β = 0.08; p = 0.04), academic performance (β = 0.09; p = 0.02), economic class (β = 0.08; p = 0.03), and body mass index (β = 0.44; p < 0.001). This model explained 22% of body image concern. Medication use due to studies, academic performance, economic class and body mass index significantly contribute to body image concern.

  12. Conditions for the onset of the current filamentation instability in the laboratory

    NASA Astrophysics Data System (ADS)

    Shukla, N.; Vieira, J.; Muggli, P.; Sarri, G.; Fonseca, R.

    2018-06-01

    The current filamentation instability (CFI) is capable of generating strong magnetic fields relevant to the explanation of radiation processes in astrophysical objects and leads to the onset of particle acceleration in collisionless shocks. Probing such extreme scenarios in the laboratory is still an open challenge. In this work, we investigate the possibility of using neutral -~e+$ beams to explore the CFI with realistic parameters, by performing two-dimensional particle-in-cell simulations. We show that CFI can occur unless the rate at which the beam expands due to finite beam emittance is larger than the CFI growth rate and as long as the role of the competing electrostatic two-stream instability (TSI) is negligible. We also show that the longitudinal energy spread, typical of plasma-based accelerated electron-positron fireball beams, plays a minor role in the growth of CFI in these scenarios.

  13. The 7-day contraceptive hormone-free interval should be consigned to history.

    PubMed

    MacGregor, E Anne; Guillebaud, John

    2018-06-26

    This review summarises the available data on the disadvantages of the 7-day contraceptive-free interval (CFI) of combined oral contraceptives (COCs), in contrast to shorter CFIs or continuous use - including flexible regimens - and provides recommendations for practice. Relevant papers were identified by Medline and PubMed. The final reference list was generated on the basis of relevance to the review, with priority given to systematic reviews and randomised controlled trials. There is considerable inter- and intra-individual variation in the absorption and metabolism of COCs. Even with perfect use, the loss of endocrine suppression during the standard 7-day CFI allows follicular development with the risk of escape ovulation in a vulnerable minority. This risk increases in typical users whenever the CFI is prolonged: late restarts are a common reason for pill omissions. Shortening or eliminating the CFI improves contraceptive efficacy using the lowest doses available, without evidence to date of compromised safety. There is no scientific evidence to support a 7-day CFI and it should be replaced either by a continuous flexible regimen, or extended regimens with a shortened CFI, prescribed first-line. In women preferring a monthly 'bleed', a 4-day CFI similarly provides a greater safety margin when pills are omitted. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  14. Validation of the Polish version of the Multidimensional Body-Self Relations Questionnaire among women.

    PubMed

    Brytek-Matera, Anna; Rogoza, Radosław

    2015-03-01

    In Poland, appropriate means to assess body image are relatively limited. The aim of the study was to evaluate the psychometric properties of the Polish version of the Multidimensional Body-Self Relations Questionnaire (MBSRQ). To do so, a sample of 341 females ranging in age from 18 to 35 years (M = 23.09; SD = 3.14) participated in the present study. Owing to the fact that the confirmatory factor analysis of the original nine-factor model was not well fitted to the data (RMSEA = 0.06; CFI = 0.75) the exploratory approach was employed. Based on parallel analysis and minimum average partial an eight-factor structure of the Polish version of the MBSRQ was distinguished. Exploratory factor analysis revealed a factorial structure similar to the original version. The proposed model was tested using an exploratory structural equation modelling approach which resulted in good fit (RMSEA = 0.04; CFI = 0.91). In the present study, the internal reliability assessed by McDonald's ω coefficient amounts from 0.66 to 0.91. In conclusion, the Polish version of the MBSRQ is a useful measure for the attitudinal component of body image assessment.

  15. Barriers to implementing the DSM-5 cultural formulation interview: a qualitative study.

    PubMed

    Aggarwal, Neil Krishan; Nicasio, Andel Veronica; DeSilva, Ravi; Boiler, Marit; Lewis-Fernández, Roberto

    2013-09-01

    The Outline for Cultural Formulation (OCF) in the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-IV) marked an attempt to apply anthropological concepts within psychiatry. The OCF has been criticized for not providing guidelines to clinicians. The DSM-5 Cultural Issues Subgroup has since converted the OCF into the Cultural Formulation Interview (CFI) for use by any clinician with any patient in any clinical setting. This paper presents perceived barriers to CFI implementation in clinical practice reported by patients (n = 32) and clinicians (n = 7) at the New York site within the DSM-5 international field trial. We used an implementation fidelity paradigm to code debriefing interviews after each CFI session through deductive content analysis. The most frequent patient threats were lack of differentiation from other treatments, lack of buy-in, ambiguity of design, over-standardization of the CFI, and severity of illness. The most frequent clinician threats were lack of conceptual relevance between intervention and problem, drift from the format, repetition, severity of patient illness, and lack of clinician buy-in. The Subgroup has revised the CFI based on these barriers for final publication in DSM-5. Our findings expand knowledge on the cultural formulation by reporting the CFI's reception among patients and clinicians.

  16. Child food insecurity increases risks posed by household food insecurity to young children's health.

    PubMed

    Cook, John T; Frank, Deborah A; Levenson, Suzette M; Neault, Nicole B; Heeren, Tim C; Black, Maurine M; Berkowitz, Carol; Casey, Patrick H; Meyers, Alan F; Cutts, Diana B; Chilton, Mariana

    2006-04-01

    The US Food Security Scale (USFSS) measures household and child food insecurity (CFI) separately. Our goal was to determine whether CFI increases risks posed by household food insecurity (HFI) to child health and whether the Food Stamp Program (FSP) modifies these effects. From 1998 to 2004, 17,158 caregivers of children ages 36 mo were interviewed in six urban medical centers. Interviews included demographics, the USFSS, child health status, and hospitalization history. Ten percent reported HFI, 12% HFI and CFI (H&CFI). Compared with food-secure children, those with HFI had significantly greater adjusted odds of fair/poor health and being hospitalized since birth, and those with H&CFI had even greater adverse effects. Participation in the FSP modified the effects of FI on child health status and hospitalizations, reducing, but not eliminating, them. Children in FSP-participating households that were HFI had lower adjusted odds of fair/poor health [1.37 (95% CI, 1.06-1.77)] than children in similar non-FSP households [1.61 (95% CI, 1.31-1.98)]. Children in FSP-participating households that were H&CFI also had lower adjusted odds of fair/poor health [1.72 (95% CI, 1.34-2.21)] than in similar non-FSP households [2.14 (95% CI, 1.81-2.54)]. HFI is positively associated with fair/poor health and hospitalizations in young children. With H&CFI, odds of fair/poor health and hospitalizations are even greater. Participation in FSP reduces, but does not eliminate, effects of FI on fair/poor health.

  17. Clinical value of the cultural formulation interview in Pune, India

    PubMed Central

    Paralikar, Vasudeo P.; Sarmukaddam, Sanjeev B.; Patil, Kanak V.; Nulkar, Amit D.; Weiss, Mitchell G.

    2015-01-01

    Context: Development of the cultural formulation interview (CFI) in DSM-5 required validation for cross-cultural and global use. Aims: To assess the overall value (OV) of CFI in the domains of feasibility, acceptability, and utility from the vantage points of clinician-interviewers, patients and accompanying relatives. Settings and Design: We conducted cross-sectional semi-structured debriefing interviews in a psychiatric outpatient clinic of a general hospital. Materials and Methods: We debriefed 36 patients, 12 relatives and eight interviewing clinicians following the audio-recorded CFI. We transformed their Likert scale responses into ordinal values – positive for agreement and negative for disagreement (range +2 to −2). Statistical Analysis: We compared mean ratings of patients, relatives and clinician-interviewers using nonparametric tests. Clinician-wise grouping of patients enabled assessment of clinician effects, inasmuch as patients were randomly interviewed by eight clinicians. We assessed the influence of the presence of relatives, clinical diagnosis and interview characteristics by comparing means. Patient and clinician background characteristics were also compared. Results: Patients, relatives and clinicians rated the CFI positively with few differences among them. Patients with serious mental disorders gave lower ratings. Rating of OV was lower for patients and clinicians when relatives were present. Clinician effects were minimal. Clinicians experienced with culturally diverse patients rated the CFI more positively. Narratives clarified the rationale for ratings. Conclusions: Though developed for the American DSM-5, the CFI was valued by clinicians, patients and relatives in out-patient psychiatric assessment in urban Pune, India. Though relatives may add information and other value, their presence in the interview may impose additional demands on clinicians. Our findings contribute to cross-cultural evaluation of the CFI. PMID:25657458

  18. Multilayer regulatory mechanisms control cleavage factor I proteins in filamentous fungi

    PubMed Central

    Rodríguez-Romero, J.; Franceschetti, M.; Bueno, E.; Sesma, A.

    2015-01-01

    Cleavage factor I (CFI) proteins are core components of the polyadenylation machinery that can regulate several steps of mRNA life cycle, including alternative polyadenylation, splicing, export and decay. Here, we describe the regulatory mechanisms that control two fungal CFI protein classes in Magnaporthe oryzae: Rbp35/CfI25 complex and Hrp1. Using mutational, genetic and biochemical studies we demonstrate that cellular concentration of CFI mRNAs is a limited indicator of their protein abundance. Our results suggest that several post-transcriptional mechanisms regulate Rbp35/CfI25 complex and Hrp1 in the rice blast fungus, some of which are also conserved in other ascomycetes. With respect to Rbp35, these include C-terminal processing, RGG-dependent localization and cleavage, C-terminal autoregulatory domain and regulation by an upstream open reading frame of Rbp35-dependent TOR signalling pathway. Our proteomic analyses suggest that Rbp35 regulates the levels of proteins involved in melanin and phenylpropanoids synthesis, among others. The drastic reduction of fungal CFI proteins in carbon-starved cells suggests that the pre-mRNA processing pathway is altered. Our findings uncover broad and multilayer regulatory mechanisms controlling fungal polyadenylation factors, which have profound implications in pre-mRNA maturation. This area of research offers new avenues for fungicide design by targeting fungal-specific proteins that globally affect thousands of mRNAs. PMID:25514925

  19. Threshold-linear analysis of measures of fertility in artificial insemination data and days to calving in beef cattle.

    PubMed

    Donoghue, K A; Rekaya, R; Bertrand, J K; Misztal, I

    2004-04-01

    Mating and calving records for 47,533 first-calf heifers in Australian Angus herds were used to examine the relationship between days to calving (DC) and two measures of fertility in AI data: 1) calving to first insemination (CFI) and 2) calving success (CS). Calving to first insemination and calving success were defined as binary traits. A threshold-linear Bayesian model was employed for both analyses: 1) DC and CFI and 2) DC and CS. Posterior means (SD) of additive covariance and corresponding genetic correlation between the DC and CFI were -0.62 d (0.19 d) and -0.66 (0.12), respectively. The corresponding point estimates between the DC and CS were -0.70 d (0.14 d) and -0.73 (0.06), respectively. These genetic correlations indicate a strong, negative relationship between DC and both measures of fertility in AI data. Selecting for animals with shorter DC intervals genetically will lead to correlated increases in both CS and CFI. Posterior means (SD) for additive and residual variance and heritability for DC for the DC-CFI analysis were 23.5 d2 (4.1 d2), 363.2 d2 (4.8 d2), and 0.06 (0.01), respectively. The corresponding parameter estimates for the DC-CS analysis were very similar. Posterior means (SD) for additive, herd-year and service sire variance and heritability for CFI were 0.04 (0.01), 0.06 (0.06), 0.14 (0.16), and 0.03 (0.01), respectively. Posterior means (SD) for additive, herd-year, and service sire variance and heritability for CS were 0.04 (0.01), 0.07 (0.07), 0.14 (0.16), and 0.03 (0.01), respectively. The similarity of the parameter estimates for CFI and CS suggest that either trait could be used as a measure of fertility in AI data. However, the definition of CFI allows the identification of animals that not only record a calving event, but calve to their first insemination, and the value of this trait would be even greater in a more complete dataset than that used in this study. The magnitude of the correlations between DC and CS-CFI suggest that it may be possible to use a multitrait approach in the evaluation of AI and natural service data, and to report one genetic value that could be used for selection purposes.

  20. Inhibition of the spindle assembly checkpoint kinase Mps-1 as a novel therapeutic strategy in malignant mesothelioma

    PubMed Central

    Szymiczek, Agata; Carbone, Michele; Pastorino, Sandra; Napolitano, Andrea; Tanji, Mika; Minaai, Michael; Pagano, Ian; Mason, Jacqueline M.; Pass, Harvey I.; Bray, Mark R.; Mak, Tak W.; Yang, Haining

    2017-01-01

    Malignant mesothelioma (MM) is an aggressive malignancy, highly resistant to current medical and surgical therapies, whose tumor cells characteristically show a high level of aneuploidy and genomic instability. We tested our hypothesis that targeting chromosomal instability in MM would improve response to therapy. TTK/Mps-1 (monopolar spindle 1 kinase) is a kinase of the spindle assembly checkpoint that controls cell division and cell fate. CFI-402257 is a novel, selective inhibitor of Mps-1 with antineoplastic activity. We found that CFI-402257 suppresses MM growth. We found that Mps-1 is overexpressed in MM and that its expression correlates with poor patients’ outcome. In vitro, CFI-402257-mediated inhibition of Mps-1 resulted in abrogation of the mitotic checkpoint, premature progression through mitosis, marked aneuploidy and mitotic catastrophe. In vivo, CFI-402257 reduced MM growth in an orthotopic, syngeneic model, when used as a single agent, and more so when used in combination with cisplatin+pemetrexed, the current standard of care. Our preclinical findings indicate that CFI-402257 is a promising novel therapeutic agent to improve the efficacy of the current chemotherapeutic regimens for MM patients. PMID:28759042

  1. Does the Cultural Formulation Interview (CFI) for the Fifth Revision of the Diagnostic and Statistical Manual of Mental Disorders (DSM-5) affect medical communication? A qualitative exploratory study from the New York site

    PubMed Central

    Aggarwal, Neil K.; DeSilva, Ravi; Nicasio, Andel V.; Boiler, Marit; Lewis-Fernández, Roberto

    2014-01-01

    Objectives Cross-cultural mental health researchers often analyze patient explanatory models of illness to optimize service provision. The Cultural Formulation Interview (CFI) is a cross-cultural assessment tool released in May 2013 with DSM-5 to revise shortcomings from the DSM-IV Outline for Cultural Formulation (OCF). The CFI field trial took place in 6 countries, 14 sites, and with 321 patients to explore its feasibility, acceptability, and clinical utility with patients and clinicians. We sought to analyze if and how CFI feasibility, acceptability, and clinical utility were related to patient-clinician communication. Design We report data from the New York site which enrolled 7 clinicians and 32 patients in 32 patient-clinician dyads. We undertook a data analysis independent of the parent field trial by conducting content analyses of debriefing interviews with all participants (n=64) based on codebooks derived from frameworks for medical communication and implementation outcomes. Three coders created codebooks, coded independently, established inter-rater coding reliability, and analyzed if the CFI affects medical communication with respect to feasibility, acceptability, and clinical utility. Results Despite racial, ethnic, cultural, and professional differences within our group of patients and clinicians, we found that promoting satisfaction through the interview, eliciting data, eliciting the patient’s perspective, and perceiving data at multiple levels were common codes that explained how the CFI affected medical communication. We also found that all but 2 codes fell under the implementation outcome of clinical utility, 2 fell under acceptability, and none fell under feasibility. Conclusion Our study offers new directions for research on how a cultural interview affects patient-clinician communication. Future research can analyze how the CFI and other cultural interviews impact medical communication in clinical settings with subsequent effects on outcomes such as medication adherence, appointment retention, and health condition. PMID:25372242

  2. Prevalence of cognitive and functional impairment in a community sample in Ribeirão Preto, Brazil.

    PubMed

    Lopes, Marcos A; Hototian, Sergio R; Bustamante, Sonia E Z; Azevedo, Dionísio; Tatsch, Mariana; Bazzarella, Mário C; Litvoc, Júlio; Bottino, Cássio M C

    2007-08-01

    This study aimed at estimating the prevalence of cognitive and functional impairment (CFI) in a community sample in Ribeirão Preto, Brazil, evaluating its distribution in relation to various socio-demographic and clinical factors. The population was a representative sample aged 60 and older, from three different socio-economic classes. Cluster sampling was applied. Instruments used to select CFI (a syndromic category that does not exclude dementia): 'Mini Mental State Examination' (MMSE), 'Fuld Object Memory Evaluation' (FOME), 'Informant Questionnaire on Cognitive Decline in the Elderly' (IQCODE), 'Bayer Activities of Daily Living Scale' (B-ADL) and clinical interviews. The data obtained were submitted to bivariate and logistic regression analysis. A sample of 1.145 elderly persons was evaluated, with a mean age of 70.9 years (60-100; DP: 7.7); 63.4% were female, and 52.8% had up to 4 years of schooling. CFI prevalence was 18.9% (n = 217). Following logistic regression analysis, higher age, low education, stroke, epilepsy and depression were associated with CFI. Female sex, widowhood, low social class and head trauma were associated with CFI only on bivariate analysis. CFI prevalence results were similar to those found by studies in Brazil, Puerto Rico and Malaysia. Cognitive and functional impairment is a rather heterogeneous condition which may be associated with various clinical conditions found in the elderly population. Due to its high prevalence and association with higher mortality and disability rates, this clinical syndrome should receive more attention on public health intervention planning.

  3. A systematic bias in the interpretation of CFI results

    Treesearch

    Warren E. Frayer

    1967-01-01

    It is not generally recognized that a serious bias arises in the estimates of annual ingrowth and accretion, two of the growth components available from continuous forest inventory (CFI). The bias is demonstrated, and suggestions for correction are given.

  4. Perspectives of family members participating in cultural assessment of psychiatric disorders: Findings from the DSM-5 International Field Trial

    PubMed Central

    Hinton, Ladson; Aggarwal, Neil; Iosif, Ana-Maria; Weiss, Mitchell; Paralikar, Vasudeo; Deshpande, Smita; Jadhav, Sushrut; Ndetei, David; Nicasio, Andel; Boiler, Marit; Lam, Peter; Avelar, Yesi; Lewis-Fernández, Roberto

    2015-01-01

    Despite the important roles families play in the lives of many persons with mental illness across cultures, there is a dearth of data worldwide on how family members perceive the process of cultural assessment as well as to how to best include them. This study addresses this gap in our knowledge through analysis of data collected across six countries as part of a DSM-5 Field Trial of the Cultural Formulation Interview (CFI). At clinician discretion, individuals who accompanied patients to the clinic visit (i.e. patient companions) at the time the CFI was conducted were invited to participate in the cultural assessment and answer questions about their experience. The specific aims of this paper are (1) to describe patterns of participation of patient companions in the CFI across the six countries, and (2) to examine the comparative feasibility, acceptability, and clinical utility of the CFI from companion perspectives through analysis of both quantitative and qualitative data. Among the 321 patient interviews, only 86 (at 4 of 12 sites) included companions, all of whom were family members or other relatives. The utility, feasibility and acceptability of the CFI were rated favorably by relatives, supported by qualitative analyses of debriefing interviews. Cross-site differences in frequency of accompaniment merit further study. PMID:25738941

  5. Barriers to Implementing the DSM-5 Cultural Formulation Interview: A Qualitative Study

    PubMed Central

    Aggarwal, Neil Krishan; Nicasio, Andel Veronica; DeSilva, Ravi; Boiler, Marit; Lewis-Fernández, Roberto

    2015-01-01

    The Outline for Cultural Formulation (OCF) in the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-IV) marked an attempt to apply anthropological concepts within psychiatry. The OCF has been criticized for not providing guidelines to clinicians. The DSM-5 Cultural Issues Subgroup has since converted the OCF into the Cultural Formulation Interview (CFI) for use by any clinician with any patient in any clinical setting. This paper presents perceived barriers to CFI implementation in clinical practice reported by patients (n=32) and clinicians (n=7) at the New York site within the DSM-5 international field trial. We used an implementation fidelity paradigm to code debriefing interviews after each CFI session through deductive content analysis. The most frequent patient threats were lack of differentiation from other treatments, lack of buy-in, ambiguity of design, over-standardization of the CFI, and severity of illness. The most frequent clinician threats were lack of conceptual relevance between intervention and problem, drift from the format, repetition, severity of patient illness, and lack of clinician buy-in. The Subgroup has revised the CFI based on these barriers for final publication in DSM-5. Our findings expand knowledge on the cultural formulation by reporting the CFI’s reception among patients and clinicians. PMID:23836098

  6. Perspectives of family members participating in cultural assessment of psychiatric disorders: findings from the DSM-5 International Field Trial.

    PubMed

    Hinton, Ladson; Aggarwal, Neil; Iosif, Ana-Maria; Weiss, Mitchell; Paralikar, Vasudeo; Deshpande, Smita; Jadhav, Sushrut; Ndetei, David; Nicasio, Andel; Boiler, Marit; Lam, Peter; Avelar, Yesi; Lewis-Fernández, Roberto

    2015-02-01

    Despite the important roles families play in the lives of many individuals with mental illness across cultures, there is a dearth of data worldwide on how family members perceive the process of cultural assessment as well as to how to best include them. This study addresses this gap in our knowledge through analysis of data collected across six countries as part of a DSM-5 Field Trial of the Cultural Formulation Interview (CFI). At clinician discretion, individuals who accompanied patients to the clinic visit (i.e. patient companions) at the time the CFI was conducted were invited to participate in the cultural assessment and answer questions about their experience. The specific aims of this paper are (1) to describe patterns of participation of patient companions in the CFI across the six countries, and (2) to examine the comparative feasibility, acceptability, and clinical utility of the CFI from companion perspectives through analysis of both quantitative and qualitative data. Among the 321 patient interviews, only 86 (at four of 12 sites) included companions, all of whom were family members or other relatives. The utility, feasibility and acceptability of the CFI were rated favourably by relatives, supported by qualitative analyses of debriefing interviews. Cross-site differences in frequency of accompaniment merit further study.

  7. Validity and reliability of the Multidimensional Body Image Scale in Malaysian university students.

    PubMed

    Gan, W Y; Mohd, Nasir M T; Siti, Aishah H; Zalilah, M S

    2012-12-01

    This study aimed to evaluate the validity and reliability of the Multidimensional Body Image Scale (MBIS), a seven-factor, 62-item scale developed for Malaysian female adolescents. This scale was evaluated among male and female Malaysian university students. A total of 671 university students (52.2% women and 47.8% men) completed a self-administered questionnaire on MBIS, Eating Attitude Test-26, and Rosenberg Self-Esteem Scale. Their height and weight were measured. Results in confirmatory factor analysis showed that the 62-item MBIS reported poor fit to the data, xhi2/df = 4.126, p < 0.001, CFI = 0.808, SRMR = 0.070, RMSEA = 0.068 (90% CI = 0.067, 0.070). After re-specification of the model, the model fit was improved with 46 items remaining, chi2/df = 3.346, p < 0.001, CFI = 0.903, SRMR = 0.053, RMSEA = 0.059 (90% CI = 0.057, 0.061), and the model showed good fit to the data for men and women separately. This 46-item MBIS had good internal consistency in both men (Cronbach's alpha = 0.88) and women (Cronbach's alpha = 0.92). In terms of construct validity, it showed positive correlations with disordered eating and body weight status, but negative correlation with self-esteem. Also, this scale discriminated well between participants with and without disordered eating. The MBIS-46 demonstrated good reliability and validity for the evaluation of body image among university students. Further studies need to be conducted to confirm the validation results of the 46-item MBIS.

  8. Functional characterization of CFI-402257, a potent and selective Mps1/TTK kinase inhibitor, for the treatment of cancer.

    PubMed

    Mason, Jacqueline M; Wei, Xin; Fletcher, Graham C; Kiarash, Reza; Brokx, Richard; Hodgson, Richard; Beletskaya, Irina; Bray, Mark R; Mak, Tak W

    2017-03-21

    Loss of cell-cycle control is a hallmark of human cancer. Cell-cycle checkpoints are essential for maintaining genome integrity and balanced growth and division. They are specifically deregulated in cancer cells and contain regulators that represent potential therapeutic targets. Monopolar spindle 1 (Mps1; also known as TTK protein kinase) is a core component of the spindle assembly checkpoint (SAC), a genome-surveillance mechanism that is important for cell survival, and has emerged as a candidate target for anticancer therapy. Here, we report the cellular and antitumor effects of CFI-402257, a potent (Mps1 K i = 0.09 ± 0.02 nM; cellular Mps1 EC 50 = 6.5 ± 0.5 nM), highly selective, and orally active small-molecule inhibitor of Mps1 that was identified through a drug-discovery program. Human cancer cells treated with CFI-402257 exhibit effects consistent with Mps1 kinase inhibition, specifically SAC inactivation, leading to chromosome missegregation, aneuploidy, and ultimately cell death. Oral administration of CFI-402257 in monotherapy or in combination with an anti-programmed cell death 1 (PD-1) antibody in mouse models of human cancer results in inhibition of tumor growth at doses that are well-tolerated. Our findings provide a rationale for the clinical evaluation of CFI-402257 in patients with solid tumors.

  9. Functional characterization of CFI-402257, a potent and selective Mps1/TTK kinase inhibitor, for the treatment of cancer

    PubMed Central

    Mason, Jacqueline M.; Wei, Xin; Fletcher, Graham C.; Kiarash, Reza; Brokx, Richard; Hodgson, Richard; Beletskaya, Irina; Bray, Mark R.; Mak, Tak W.

    2017-01-01

    Loss of cell-cycle control is a hallmark of human cancer. Cell-cycle checkpoints are essential for maintaining genome integrity and balanced growth and division. They are specifically deregulated in cancer cells and contain regulators that represent potential therapeutic targets. Monopolar spindle 1 (Mps1; also known as TTK protein kinase) is a core component of the spindle assembly checkpoint (SAC), a genome-surveillance mechanism that is important for cell survival, and has emerged as a candidate target for anticancer therapy. Here, we report the cellular and antitumor effects of CFI-402257, a potent (Mps1 Ki = 0.09 ± 0.02 nM; cellular Mps1 EC50 = 6.5 ± 0.5 nM), highly selective, and orally active small-molecule inhibitor of Mps1 that was identified through a drug-discovery program. Human cancer cells treated with CFI-402257 exhibit effects consistent with Mps1 kinase inhibition, specifically SAC inactivation, leading to chromosome missegregation, aneuploidy, and ultimately cell death. Oral administration of CFI-402257 in monotherapy or in combination with an anti-programmed cell death 1 (PD-1) antibody in mouse models of human cancer results in inhibition of tumor growth at doses that are well-tolerated. Our findings provide a rationale for the clinical evaluation of CFI-402257 in patients with solid tumors. PMID:28270606

  10. The Career Futures Inventory-Revised: Measuring Dimensions of Career Adaptability

    ERIC Educational Resources Information Center

    Rottinghaus, Patrick J.; Buelow, Kristine L.; Matyja, Anna; Schneider, Madalyn R.

    2012-01-01

    This study reports the development and initial validation of the "Career Futures Inventory-Revised" (CFI-R) in two large samples of university students. The 28-item CFI-R assesses aspects of career adaptability, including positive career planning attitudes, general outcome expectations, and components of Parsons' tripartite model and…

  11. Prosthetic reconstruction of a patient with an acquired nasal defect using extraoral implants and a CAD/CAM copy-milled bar.

    PubMed

    Vera, Carolina; Barrero, Carlos; Shockley, William; Rothenberger, Sandra; Minsley, Glenn; Drago, Carl

    2014-10-01

    Traditionally, patients with maxillofacial defects have been challenging to treat. A multitude of challenges associated with maxillofacial prosthetic treatment are not typically seen with patients who need conventional prosthodontic treatment. These types of patients generally require replacement of significant amounts of hard and soft tissues than do conventional prosthodontic patients. Most maxillofacial patients also warrant more emotional support than do conventional prosthodontic patients. Successful maxillofacial prosthetics still need to embrace the traditional goals of prosthodontic treatment: stability, support, retention, and esthetics. It is unlikely that a maxillofacial prosthesis will exactly duplicate the anatomy and function of missing or damaged structures. Although craniofacial implants (CFI's) have lower cumulative survival rates (CSR's) than intraoral endosseous implants, osseointegrated CFI's have proven to be significant adjuncts to improving retention of maxillofacial prostheses. However, CSR's of CFI's have been reported to be lower than CSR's for intraoral endosseous implants. Lately, computer-assisted design and computer-assisted machining (CAD/CAM) has been used in dentistry to facilitate fabrication of implant-supported frameworks. CAD/CAM protocols have numerous advantages over conventional casting techniques, including improved accuracy and biocompatibility, and decreased costs. The purpose of this paper is to review the literature on cumulative survival rates (CSR's) reported for CFI's and to illustrate the treatment of a maxillofacial patient using CFI's and a CAD/CAM copy-milled framework for retention and support of a nasal prosthesis. © 2014 by the American College of Prosthodontists.

  12. Does the Cultural Formulation Interview for the fifth revision of the diagnostic and statistical manual of mental disorders (DSM-5) affect medical communication? A qualitative exploratory study from the New York site.

    PubMed

    Aggarwal, Neil K; Desilva, Ravi; Nicasio, Andel V; Boiler, Marit; Lewis-Fernández, Roberto

    2015-01-01

    Cross-cultural mental health researchers often analyze patient explanatory models of illness to optimize service provision. The Cultural Formulation Interview (CFI) is a cross-cultural assessment tool released in May 2013 with DSM-5 to revise shortcomings from the DSM-IV Outline for Cultural Formulation (OCF). The CFI field trial took place in 6 countries, 14 sites, and with 321 patients to explore its feasibility, acceptability, and clinical utility with patients and clinicians. We sought to analyze if and how CFI feasibility, acceptability, and clinical utility were related to patient-clinician communication. We report data from the New York site which enrolled 7 clinicians and 32 patients in 32 patient-clinician dyads. We undertook a data analysis independent of the parent field trial by conducting content analyses of debriefing interviews with all participants (n = 64) based on codebooks derived from frameworks for medical communication and implementation outcomes. Three coders created codebooks, coded independently, established inter-rater coding reliability, and analyzed if the CFI affects medical communication with respect to feasibility, acceptability, and clinical utility. Despite racial, ethnical, cultural, and professional differences within our group of patients and clinicians, we found that promoting satisfaction through the interview, eliciting data, eliciting the patient's perspective, and perceiving data at multiple levels were common codes that explained how the CFI affected medical communication. We also found that all but two codes fell under the implementation outcome of clinical utility, two fell under acceptability, and none fell under feasibility. Our study offers new directions for research on how a cultural interview affects patient-clinician communication. Future research can analyze how the CFI and other cultural interviews impact medical communication in clinical settings with subsequent effects on outcomes such as medication adherence, appointment retention, and health condition.

  13. A child feeding index is superior to WHO IYCF indicators in explaining length-for-age Z-scores of young children in rural Cambodia

    PubMed Central

    Reinbott, Anika; Kuchenbecker, Judith; Herrmann, Johannes; Jordan, Irmgard; Muehlhoff, Ellen; Kevanna, Ou; Krawinkel, Michael

    2015-01-01

    Background: Adequate young child feeding practices are influenced by a multitude of factors which affect growth and development. A combination of indicators is needed to explain the role of complementary feeding practices in growth retardation. Methods: A cross-sectional nutrition baseline survey was conducted in rural Cambodia in September 2012. Villages in pre-selected communes were randomly selected using stunting as a primary indicator. Data were collected from 803 randomly selected households with children aged 6–23 months, based on a standardised questionnaire and on length/height and weight measurements of mother and child. WHO Infant and Young Child Feeding (IYCF) indicators [minimum dietary diversity (MDD), minimum meal frequency (MMF), minimum acceptable diet (MAD)] and a child feeding index (CFI) were created. The latter consisted of five components: breastfeeding, use of bottle, dietary diversity, food frequency and meal frequency which were adjusted for three age groups: 6–8, 9–11 and 12–23 months. The highest possible score was 10. Associations between length-for-age Z-scores (LAZ) and WHO indicators or CFI were explored. Results: Mean (SD) LAZ was −1.25 (1.14) (n  =  801). Mean (range) CFI was 6.7 (1–10) (n  =  797). Mean CFI was highest in the 9–11-months age group (7.93) and lowest for those aged 12–23 months (5.96). None of the WHO IYCF indicators was associated with LAZ, whereas CFI showed significant association with LAZ (P < 0.01). The association between higher CFI scores and LAZ became weaker as age increased. Conclusion: The results highlight the need to include a wide range of information in the analysis in order to understand the association between appropriate infant feeding practices and child growth. PMID:25226288

  14. Tracking early decline in cognitive function in older individuals at risk for Alzheimer disease dementia: the Alzheimer's Disease Cooperative Study Cognitive Function Instrument.

    PubMed

    Amariglio, Rebecca E; Donohue, Michael C; Marshall, Gad A; Rentz, Dorene M; Salmon, David P; Ferris, Steven H; Karantzoulis, Stella; Aisen, Paul S; Sperling, Reisa A

    2015-04-01

    Several large-scale Alzheimer disease (AD) secondary prevention trials have begun to target individuals at the preclinical stage. The success of these trials depends on validated outcome measures that are sensitive to early clinical progression in individuals who are initially asymptomatic. To investigate the utility of the Cognitive Function Instrument (CFI) to track early changes in cognitive function in older individuals without clinical impairment at baseline. Longitudinal study from February 2002 through February 2007 at participating Alzheimer's Disease Cooperative Study sites. Individuals were followed up annually for 48 months after the baseline visit. The study included 468 healthy older individuals (Clinical Dementia Rating scale [CDR] global scores of 0, above cutoff on the modified Mini-Mental State Examination and Free and Cued Selective Reminding Test) (mean [SD] age, 79.4 [3.6] years; age range, 75.0-93.8 years). All study participants and their study partners completed the self and partner CFIs annually. Individuals also underwent concurrent annual neuropsychological assessment and APOE genotyping. The CFI scores between clinical progressors (CDR score, ≥0.5) and nonprogressors (CDR score, 0) and between APOE ε4 carriers and noncarriers were compared. Correlations of change between the CFI scores and neuropsychological performance were assessed longitudinally. At 48 months, group differences between clinical progressors and non-progressors were significant for self (2.13, SE=0.45, P<.001), partner (5.08, SE=0.59, P<.001), and self plus partner (7.04, SE=0.83, P<.001) CFI total scores. At month 48, APOE ε4 carriers had greater progression than noncarriers on the partner (1.10, SE=0.44, P<.012) and self plus partner (1.56, SE=0.63, P<.014) CFI scores. Both self and partner CFI change were associated with longitudinal cognitive decline (self, ρ=0.32, 95% CI, 0.13 to 0.46; partner, ρ=0.56, 95% CI, 0.42 to 0.68), although findings suggest self-report may be more accurate early in the process, whereas accuracy of partner report improves when there is progression to cognitive impairment. Demonstrating long-term clinical benefit will be critical for the success of recently launched secondary prevention trials. The CFI appears to be a brief, but informative potential outcome measure that provides insight into functional abilities at the earliest stages of disease.

  15. Satellite optical and radar data used to track wetland forest impact and short-term recovery from Hurricane Katrina

    USGS Publications Warehouse

    Ramsey, Elijah W.; Rangoonwala, A.; Middleton, B.; Lu, Z.

    2009-01-01

    Satellite Landsat Thematic Mapper (TM) and RADARSAT-1 (radar) satellite image data collected before and after the landfall of Hurricane Katrina in the Pearl River Wildlife Management Area on the Louisiana-Mississippi border, USA, were applied to the study of forested wetland impact and recovery. We documented the overall similarity in the radar and optical satellite mapping of impact and recovery patterns and highlighted some unique differences that could be used to provide consistent and relevant ecological monitoring. Satellite optical data transformed to a canopy foliage index (CFI) indicated a dramatic decrease in canopy cover immediately after the storm, which then recovered rapidly in the Taxodium distichum (baldcypress) and Nyssa aquatica (water tupelo) forest. Although CFI levels in early October indicated rapid foliage recovery, the abnormally high radar responses associated with the cypress forest suggested a persistent poststorm difference in canopy structure. Impact and recovery mapping results showed that even though cypress forests experienced very high wind speeds, damage was largely limited to foliage loss. Bottomland hardwoods, experiencing progressively lower wind speeds further inland, suffered impacts ranging from increased occurrences of downed trees in the south to partial foliage loss in the north. In addition, bottomland hardwood impact and recovery patterns suggested that impact severity was associated with a difference in stand structure possibly related to environmental conditions that were not revealed in the prehurricane 25-m optical and radar image analyses.

  16. 75 FR 76617 - Use of Community Development Loans by Community Financial Institutions To Secure Advances...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-09

    ... long term advances to CFI members for purposes of financing community development activities. Section... provided that a Bank could make a long-term advance to a member only for the purposes of providing funds to the member for residential housing finance, except that it also allowed long-term advances to CFI...

  17. Measuring Change in Career Counseling: Validation of the "Career Futures Inventory-Revised"

    ERIC Educational Resources Information Center

    Rottinghaus, Patrick J.; Eshelman, Alec; Gore, Jonathan S.; Keller, Kari J.; Schneider, Madalyn; Harris, Kristine L.

    2017-01-01

    This retrospective chart review study examined the factor structure of the "Career Futures Inventory-Revised" (CFI-R; Rottinghaus et al. in "J Career Assess" 20:123-139, 2012) and its utility as a career counseling outcome measure using a sample of 332 clients from a university career center. The CFI-R examines career agency…

  18. Training on the DSM-5 Cultural Formulation Interview Improves Cultural Competence in General Psychiatry Residents: A Multi-site Study.

    PubMed

    Mills, Stacia; Wolitzky-Taylor, Kate; Xiao, Anna Q; Bourque, Marie Claire; Rojas, Sandra M Peynado; Bhattacharya, Debanjana; Simpson, Annabelle K; Maye, Aleea; Lo, Pachida; Clark, Aaron; Lim, Russell; Lu, Francis G

    2016-10-01

    The authors assessed whether a 1-h didactic session on the DSM-5 Cultural Formulation Interview (CFI) improves cultural competence of general psychiatry residents. Psychiatry residents at six residency programs completed demographics and pre-intervention questionnaires, were exposed to a 1-h session on the CFI, and completed a post-intervention questionnaire. Repeated measures ANCOVA compared pre- to post-intervention change. Linear regression assessed whether previous cultural experience predicted post-intervention scores. Mean scores on the questionnaire significantly changed from pre- to post-intervention (p < 0.001). Previous cultural experience did not predict post-intervention scores. Psychiatry residents' cultural competence scores improved with a 1-h session on the CFI but with notable limitations.

  19. Simulating water and nitrogen loss from an irrigated paddy field under continuously flooded condition with Hydrus-1D model.

    PubMed

    Yang, Rui; Tong, Juxiu; Hu, Bill X; Li, Jiayun; Wei, Wenshuo

    2017-06-01

    Agricultural non-point source pollution is a major factor in surface water and groundwater pollution, especially for nitrogen (N) pollution. In this paper, an experiment was conducted in a direct-seeded paddy field under traditional continuously flooded irrigation (CFI). The water movement and N transport and transformation were simulated via the Hydrus-1D model, and the model was calibrated using field measurements. The model had a total water balance error of 0.236 cm and a relative error (error/input total water) of 0.23%. For the solute transport model, the N balance error and relative error (error/input total N) were 0.36 kg ha -1 and 0.40%, respectively. The study results indicate that the plow pan plays a crucial role in vertical water movement in paddy fields. Water flow was mainly lost through surface runoff and underground drainage, with proportions to total input water of 32.33 and 42.58%, respectively. The water productivity in the study was 0.36 kg m -3 . The simulated N concentration results revealed that ammonia was the main form in rice uptake (95% of total N uptake), and its concentration was much larger than for nitrate under CFI. Denitrification and volatilization were the main losses, with proportions to total consumption of 23.18 and 14.49%, respectively. Leaching (10.28%) and surface runoff loss (2.05%) were the main losses of N pushed out of the system by water. Hydrus-1D simulation was an effective method to predict water flow and N concentrations in the three different forms. The study provides results that could be used to guide water and fertilization management and field results for numerical studies of water flow and N transport and transformation in the future.

  20. 75 FR 7990 - Use of Community Development Loans by Community Financial Institutions To Secure Advances...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-23

    ... activities and to allow Banks to make long-term advances to CFI members for purposes of financing community... activities as eligible collateral for advances, to provide that CFI members may use long term advances to... provided that a Bank could make a long-term advance to a member only for the purposes of providing funds to...

  1. Culture and Psychiatric Evaluation: Operationalizing Cultural Formulation for DSM-5

    PubMed Central

    Lewis-Fernández, Roberto; Aggarwal, Neil Krishan; Bäärnhielm, Sofie; Rohlof, Hans; Kirmayer, Laurence J.; Weiss, Mitchell G.; Jadhav, Sushrut; Hinton, Ladson; Alarcón, Renato D.; Bhugra, Dinesh; Groen, Simon; van Dijk, Rob; Qureshi, Adil; Collazos, Francisco; Rousseau, Cécile; Caballero, Luis; Ramos, Mar; Lu, Francis

    2015-01-01

    The Outline for Cultural Formulation (OCF) introduced with DSM-IV provided a framework for clinicians to organize cultural information relevant to diagnostic assessment and treatment planning. However, use of the OCF has been inconsistent, raising questions about the need for guidance on implementation, training, and application in diverse settings. To address this need, DSM-5 introduced a cultural formulation interview (CFI) that operationalizes the process of data collection for the OCF. The CFI includes patient and informant versions and 12 supplementary modules addressing specific domains of the OCF. This article summarizes the literature reviews and analyses of experience with the OCF conducted by the DSM-5 Cross-Cultural Issues Subgroup (DCCIS) that informed the development of the CFI. We review the history and contents of the DSM-IV OCF, its use in training programs, and previous attempts to render it operational through questionnaires, protocols, and semi-structured interview formats. Results of research based on the OCF are discussed. For each domain of the OCF, we summarize findings from the DCCIS that led to content revision and operationalization in the CFI. The conclusion discusses training and implementation issues essential to service delivery. PMID:24865197

  2. On the Computation of the RMSEA and CFI from the Mean-And-Variance Corrected Test Statistic with Nonnormal Data in SEM.

    PubMed

    Savalei, Victoria

    2018-01-01

    A new type of nonnormality correction to the RMSEA has recently been developed, which has several advantages over existing corrections. In particular, the new correction adjusts the sample estimate of the RMSEA for the inflation due to nonnormality, while leaving its population value unchanged, so that established cutoff criteria can still be used to judge the degree of approximate fit. A confidence interval (CI) for the new robust RMSEA based on the mean-corrected ("Satorra-Bentler") test statistic has also been proposed. Follow up work has provided the same type of nonnormality correction for the CFI (Brosseau-Liard & Savalei, 2014). These developments have recently been implemented in lavaan. This note has three goals: a) to show how to compute the new robust RMSEA and CFI from the mean-and-variance corrected test statistic; b) to offer a new CI for the robust RMSEA based on the mean-and-variance corrected test statistic; and c) to caution that the logic of the new nonnormality corrections to RMSEA and CFI is most appropriate for the maximum likelihood (ML) estimator, and cannot easily be generalized to the most commonly used categorical data estimators.

  3. Mitigating cold flow problems of biodiesel: Strategies with additives

    NASA Astrophysics Data System (ADS)

    Mohanan, Athira

    The present thesis explores the cold flow properties of biodiesel and the effect of vegetable oil derived compounds on the crystallization path as well as the mechanisms at play at different stages and length scales. Model systems including triacylglycerol (TAG) oils and their derivatives, and a polymer were tested with biodiesel. The goal was to acquire the fundamental knowledge that would help design cold flow improver (CFI) additives that would address effectively and simultaneously the flow problems of biodiesel, particularly the cloud point (CP) and pour point (PP). The compounds were revealed to be fundamentally vegetable oil crystallization modifiers (VOCM) and the polymer was confirmed to be a pour point depressant (PPD). The results obtained with the VOCMs indicate that two cis-unsaturated moieties combined with a trans-/saturated fatty acid is a critical structural architecture for depressing the crystallization onset by a mechanism wherein while the straight chain promotes a first packing with the linear saturated FAMEs, the kinked moieties prevent further crystallization. The study of model binary systems made of a VOCM and a saturated FAME with DSC, XRD and PLM provided a complete phase diagram including the thermal transformation lines, crystal structure and microstructure that impact the phase composition along the different crystallization stages, and elicited the competing effects of molecular mass, chain length mismatch and isomerism. The liquid-solid boundary is discussed in light of a simple thermodynamic model based on the Hildebrand equation and pair interactions. In order to test for synergies, the PP and CP of a biodiesel (Soy1500) supplemented with several VOCM and PLMA binary cocktails were measured using a specially designed method inspired by ASTM standards. The results were impressive, the combination of additives depressed CP and PP better than any single additive. The PLM and DSC results suggest that the cocktail additives are most effective when the right molecular structure and optimal concentration are provided. The cocktail mixture achieves then tiny crystals that are prevented from aggregating for an extended temperature range. The results of the study can be directly used for the design of functional and economical CFI from vegetable oils and their derivatives.

  4. The Centre for Food Innovation -- Research Areas and Potential Projects

    DTIC Science & Technology

    2013-04-01

    support gut health ( probiotics /prebiotics/bacteriocins), development of snack products (bars, FD fruit, HPP fruit, FD yoghurt etc.), novel ingredients...Defence feeding needs and requirements. Possible research areas identified for the CFI include:  dairy products ,  long-shelf-life foods such as...It is envisaged that the CFI collaboration will include the prototyping of novel foods designed specifically for Defence needs. Successful products

  5. Do therapeutic imagery practices affect physiological and emotional indicators of threat in high self-critics?

    PubMed

    Duarte, Joana; McEwan, Kirsten; Barnes, Christopher; Gilbert, Paul; Maratos, Frances A

    2015-09-01

    Imagery is known to be a powerful means of stimulating various physiological processes and is increasingly used within standard psychological therapies. Compassion-focused imagery (CFI) has been used to stimulate affiliative emotion in people with mental health problems. However, evidence suggests that self-critical individuals may have particular difficulties in this domain with single trials. The aim of the present study was to further investigate the role of self-criticism in responsiveness to CFI by specifically pre-selecting participants based on trait self-criticism. Using the Forms of Self-Criticism/Self-Reassuring Scale, 29 individuals from a total sample of 139 were pre-selected to determine how self-criticism impacts upon an initial instance of imagery. All participants took part in three activities: a control imagery intervention (useable data N = 25), a standard CFI intervention (useable data N = 25), and a non-intervention control (useable data N = 24). Physiological measurements (alpha amylase) as well as questionnaire measures of emotional responding (i.e., the Positive and Negative Affect Schedule, the Types of Positive Affect Scale, and the State Adult Attachment Scale) were taken before and after the different interventions. Following both imagery interventions, repeated measures analyses revealed that alpha amylase increased significantly for high self-critics compared with low self-critics. High self-critics (HSC) also reported greater insecurity on entering the imagery session and more negative CFI experiences compared with low self-critics. Data demonstrate that HSC respond negatively to imagery interventions in a single trial. This highlights that imagery focused therapies (e.g., CFI) need interventions that manage fears, blocks, and resistances to the techniques, particularly in HSC. An initial instance of imagery (e.g., CFI) can be frightening for people who have a tendency to be self-critical. This research provides examples of physiological and emotional responses to imagery type therapies in high and low self-critics, and associated clinical implications. Therapists may find it helpful to be mindful that when introducing imagery based therapies, highly self-critical patients need interventions that manage fears, blocks, and resistances to the techniques. © 2014 The British Psychological Society.

  6. Preparation of heterocyclic block copolymer from perfluoroalkylene oxide alpha, omega-diamidoximes

    NASA Technical Reports Server (NTRS)

    Ross, L. O.; Rosser, R. W.; Iannone, M. (Inventor)

    1979-01-01

    Diamidoxime monomers are intermolecularly and thermally condensed to form a heat and chemical resistant polymer containing 1,2,4-oxadiazole linkages with identical bivalent organic radicals or any combination of bivalent organic radicals selected from the group consisting of -(CX(sub 2))p-, wherein P ranges from 2 to 8 when X is fluorine and 2 to 18 when X is hydrogen, chlorine, nitro or aryl; arylene; and an oligometric or polymeric radical prepared by reacting a dicarboxylic acid halide with a fluorinated epoxide and having the formula: (CFY(OCF(sub 2)CFY)sub m)O(CX(sub 2))(sub p)O(CFYCF(sub 2)O)(sub n)CFY wherein Y is flourine or tryifluoromethyl, X is nitro, aryl, hydrogen, chlorine or fluorine, preferably the latter, p ranges from 1 to 18 and m+n ranges from 2 to 7.

  7. The relationship of certified flight instructors' emotional intelligence levels on flight student advancement

    NASA Astrophysics Data System (ADS)

    Hokeness, Mark Merrill

    Aviation researchers estimate airline companies will require nearly 500,000 pilots in the next 20 years. The role of a Certified Flight Instructor (CFI) is to move student pilots to professional pilots with training typically conducted in one-on-one student and instructor sessions. The knowledge of aviation, professionalism as a teacher, and the CFI’s interpersonal skills can directly affect the successes and advancement of a student pilot. A new and emerging assessment of people skills is known as emotional intelligence (EI). The EI of the CFI can and will affect a flight students’ learning experiences. With knowledge of emotional intelligence and its effect on flight training, student pilot dropouts from aviation may be reduced, thus helping to ensure an adequate supply of pilots. Without pilots, the growth of the commercial aviation industry will be restricted. This mixed method research study established the correlation between a CFI’s measured EI levels and the advancement of flight students. The elements contributing to a CFI’s EI level were not found to be teaching or flight-related experiences, suggesting other life factors are drawn upon by the CFI and are reflected in their emotional intelligence levels presented to flight students. Students respond positively to CFIs with higher levels of emotional intelligence. Awareness of EI skills by both the CFI and flight student contribute to flight student successes and advancement.

  8. A hybrid framework for assessing maize drought vulnerability in Sub-Saharan Africa

    NASA Astrophysics Data System (ADS)

    Kamali, B.; Abbaspour, K. C.; Wehrli, B.; Yang, H.

    2017-12-01

    Drought has devastating impacts on crop yields. Quantifying drought vulnerability is the first step to better design of mitigation policies. The vulnerability of crop yield to drought has been assessed with different methods, however they lack a standardized base to measure its components and a procedure that facilitates spatial and temporal comparisons. This study attempts to quantify maize drought vulnerability through linking the Drought Exposure Index (DEI) to the Crop Failure Index (CFI). DEI and CFI were defined by fitting probability distribution functions to precipitation and maize yield respectively. To acquire crop drought vulnerability index (CDVI), DEI and CFI were combined in a hybrid framework which classifies CDVI with the same base as DEI and CFI. The analysis were implemented on Sub-Saharan African countries using maize yield simulated with the Environmental Policy Integrated Climate (EPIC) model at 0.5° resolution. The model was coupled with the Sequential Uncertainty Fitting algorithm for calibration at country level. Our results show that Central Africa and those Western African countries located below the Sahelian strip receive higher amount of precipitation, but experience high crop failure. Therefore, they are identified as more vulnerable regions compared to countries such as South Africa, Tanzania, and Kenya. We concluded that our hybrid approach complements information on crop drought vulnerability quantification and can be applied to different regions and scales.

  9. Low cycle fatigue and creep fatigue interaction behavior of 9Cr-0.5Mo-1.8W-V-Nb heat-resistant steel at high temperature

    NASA Astrophysics Data System (ADS)

    Wang, Xiaowei; Zhang, Wei; Gong, Jianming; Wahab, Magd Abdel

    2018-07-01

    In this paper, Low Cycle Fatigue (LCF) and Creep-Fatigue Interaction (CFI) behavior of 9Cr-0.5Mo-1.8 W-V-Nb heat-resistant steel (ASME Grade P92 steel) at elevated temperature of 600 °C are investigated. Strain controlled LCF tests are conducted in fully reversed triangular waveform at different strain amplitudes ranging from 0.2% to 0.8%. CFI tests are conducted at 0.4% strain amplitude in trapezoid waveform with tensile hold time varying from 1 min to 60 min and compressive hold time varying from 1 min to 10 min. During LCF and CFI loadings, the evolution of cyclic stress, mean stress and stress relaxation behavior are investigated. It turns out that the softening behavior and lifetime degradation are dependent on strain amplitude, hold time and hold direction. In addition, the microstructure evolution and fracture behavior are characterized by optical, scanning and transmission electron microscope. The initial rapid softening behavior is attributed to the quick elimination of low angle boundaries, whereas no obvious microstructure alteration appears in the stable stage. Fracture behavior analysis reveals creep voids in long-term CFI tests facilitates the initiation and propagation of secondary cracks. The different responses of outer surface oxidation layer during cycling provides an explanation for severer damage of compressive hold and also accounts for the observed various fracture behavior of failed samples.

  10. [Investigation of exciting light and plant leaves age effects on chlorophyll fluorescense of radish plants].

    PubMed

    Nesterenko, T V; Tikhomirov, A A; Shikhov, V N

    2012-01-01

    The effect of exciting light intensity and leaves age on characteristics of slow stage of chlorophyll fluorescence induction (CFI) of radish leaves has been investigated. Light dependence of the relationship of maximum fluorescence intensity in the peak P and the stationary fluorescence level (F(P)/F(S)) and also light dependence of temporal characteristics of CFI (T0.5 - half decrease of chlorophyll fluorescence intensity during slow stage of fluorescence induction and tmin - summarized CFI characteristics derived by calculating via integral proportional to variable part of illuminated in the result of chlorophyll fluorescence energy during slow stage of CFI) have been studied. Plants were grown in controlled conditions of light culture at 100 Wt/m2 of photosynthetic active radiation (PAR). It has been shown that variability of the characteristics under study, associated with the effect of leaves age, significantly decreases at exciting light intensity equal to 40 Wt/m2 of PAR and more. The lowest effect of leaves age on the value of fluorescence characteristics for T0.5 and tmin and also for F(P)/F(S) ratio was observed at the intensity of exciting fluorescence light of 60 Wt/m2 of PAR. In the researched range of light intensities the temporal characteristics of T0.5 and tmin for uneven-aged radish leaves appeared to be by an order less responsive to the intensity changes of exciting fluorescence light as compared with F(P)/F(S) ratio.

  11. The relationship between performance and flow state in tennis competition.

    PubMed

    Koehn, S; Morris, T

    2012-08-01

    The study aimed to examine 1) the validity of the nine-factor flow model in tennis competition; 2) differences in flow state between athletes who won or lost their competition match; 3) the link between flow and subjective performance; and 4) flow dimensions as predictors of performance outcome The sample consisted of 188 junior tennis players (115 male, 73 female) between 12 and 18 years of age. Participants' performance was recorded during junior ranking-list tournaments. Following the completion of a tennis competition match, participants completed the Flow State Scale-2 and a subjective performance outcome measure. Acceptable flow model fit indices of CFI, TLI, SRMR, and RMSEA were only found for winning athletes. The group of winning athletes scored significantly higher on all nine flow dimensions, except time transformation, than losing athletes, showing statistically significant differences for challenge-skills balance, clear goals, sense of control, and autotelic experience. Significant correlation coefficients were found between flow state and subjective performance assessments. The binary logistic regression revealed concentration on the task and sense of control to be significant predictors of performance outcome. The predictor variables explained 13% of the variance in games won. The study showed that athletes who win or lose perceived flow state differently. Studies using retrospective assessments need to be aware that subjective experience could be biased by performance outcomes. Pinpointing psychological variables and their impact on ecologically valid measures, such as performance results, would support the development of effective intervention studies to increase performance in sport competition.

  12. Instant screening and verification of carbapenemase activity in Bacteroides fragilis in positive blood culture, using matrix-assisted laser desorption ionization--time of flight mass spectrometry.

    PubMed

    Johansson, Åsa; Nagy, Elisabeth; Sóki, József

    2014-08-01

    Rapid identification of isolates in positive blood cultures are of great importance to secure correct treatment of septicaemic patients. As antimicrobial resistance is increasing, rapid detection of resistance is crucial. Carbapenem resistance in Bacteroides fragilis associated with cfiA-encoded class B metallo-beta-lactamase is emerging. In our study we spiked blood culture bottles with 26 B. fragilis strains with various cfiA-status and ertapenem MICs. By using main spectra specific for cfiA-positive and cfiA-negative B. fragilis strains, isolates could be screened for resistance. To verify strains that were positive in the screening, a carbapenemase assay was performed where the specific peaks of intact and hydrolysed ertapenem were analysed with matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS). We show here that it is possible to correctly identify B. fragilis and to screen for enzymic carbapenem resistance directly from the pellet of positive blood cultures. The carbapenemase assay to verify the presence of the enzyme was successfully performed on the pellet from the direct identification despite the presence of blood components. The result of the procedure was achieved in 3 h. Also the Bruker mass spectrometric β-lactamase assay (MSBL assay) prototype software was proven not only to be based on an algorithm that correlated with the manual inspection of the spectra, but also to improve the interpretation by showing the variation in the dataset. © 2014 The Authors.

  13. Long-term outcome of concurrent chemoradiotherapy with elective nodal irradiation for inoperable esophageal cancer.

    PubMed

    Jing, Zhao; Chen, Tian; Zhang, Xuebang; Wu, Shixiu

    2017-09-01

    Elective nodal irradiation (ENI) might improve overall survival in patients with inoperable esophageal cancer. We conducted a retrospective analysis to assess the long-term survival and toxicity of esophageal cancer patients treated with ENI versus conventional-field irradiation (CFI). All data in the present study were based on our institutional experience from 2000 to 2005 of patients with inoperable esophageal cancer treated with ENI or CFI plus two concurrent cycles of paclitaxel/cisplatin. Based on the inclusion and exclusion criteria, 89 patients were included in the analysis. Of these patients, 51 were treated with ENI, whereas 38 were treated with CFI. For the per-protocol population, the patients in the ENI group significantly improved in terms of their 10-year disease-specific overall survival (43.1% vs 10.5%, P = 0.019), 10-year disease-free survival (36.7% vs 10.2%, P = 0.040) and 10-year local recurrence-free survival (47.2% vs 17.2%, P = 0.018) compared with the CFI group. Aside from radiation esophagitis, the incidence of grade 3 or greater acute toxicities did not differ between the two groups. Multivariate analysis showed that radiation field, tumor length and clinical stage were independent prognostic factors associated with OS. Concurrent chemoradiotherapy with ENI improves both disease-specific overall survival and loco-regional control in patients with inoperable esophageal cancer receiving per-protocol treatment. The regimen has a manageable tolerability profile. © 2017 The Authors. Cancer Science published by John Wiley & Sons Australia, Ltd on behalf of Japanese Cancer Association.

  14. Family structure and child food insecurity.

    PubMed

    Miller, Daniel P; Nepomnyaschy, Lenna; Ibarra, Gabriel Lara; Garasky, Steven

    2014-07-01

    We examined whether food insecurity was different for children in cohabiting or repartnered families versus those in single-mother or married-parent (biological) families. We compared probabilities of child food insecurity (CFI) across different family structures in 4 national data sets: the Early Childhood Longitudinal Study-Birth Cohort (ECLS-B), the Fragile Families and Child Wellbeing Study (FFCWS), the Early Childhood Longitudinal Study-Kindergarten Cohort (ECLS-K), and the Panel Study of Income Dynamics-Child Development Supplement (PSID-CDS). Unadjusted probabilities of CFI in cohabiting or repartnered families were generally higher than in married-biological-parent families and often statistically indistinguishable from those of single-mother families. However, after adjustment for sociodemographic factors, most differences between family types were attenuated and most were no longer statistically significant. Although children whose biological parents are cohabiting or whose biological mothers have repartnered have risks for food insecurity comparable to those in single-mother families, the probability of CFI does not differ by family structure when household income, family size, and maternal race, ethnicity, education, and age were held at mean levels.

  15. Molecular Regulation of Alternative Polyadenylation (APA) within the Drosophila Nervous System.

    PubMed

    Vallejos Baier, Raul; Picao-Osorio, Joao; Alonso, Claudio R

    2017-10-27

    Alternative polyadenylation (APA) is a widespread gene regulatory mechanism that generates mRNAs with different 3'-ends, allowing them to interact with different sets of RNA regulators such as microRNAs and RNA-binding proteins. Recent studies have shown that during development, neural tissues produce mRNAs with particularly long 3'UTRs, suggesting that such extensions might be important for neural development and function. Despite this, the mechanisms underlying neural APA are not well understood. Here, we investigate this problem within the Drosophila nervous system, focusing on the roles played by general cleavage and polyadenylation factors (CPA factors). In particular, we examine the model that modulations in CPA factor concentration may affect APA during development. For this, we first analyse the expression of the Drosophila orthologues of all mammalian CPA factors and note that their expression decreases during embryogenesis. In contrast to this global developmental decrease in CPA factor expression, we see that cleavage factor I (CFI) expression is actually elevated in the late embryonic central nervous system, suggesting that CFI might play a special role in neural tissues. To test this, we use the UAS/Gal4 system to deplete CFI proteins from neural tissue and observe that in this condition, multiple genes switch their APA patterns, demonstrating a role of CFI in APA control during Drosophila neural development. Furthermore, analysis of genes with 3'UTR extensions of different length leads us to suggest a novel relation between 3'UTR length and sensitivity to CPA factor expression. Our work thus contributes to the understanding of the mechanisms of APA control within the developing central nervous system. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  16. Field demonstration of on-site analytical methods for TNT and RDX in ground water

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Craig, H.; Ferguson, G.; Markos, A.

    1996-12-31

    A field demonstration was conducted to assess the performance of eight commercially-available and emerging colorimetric, immunoassay, and biosensor on-site analytical methods for explosives 2,4,6-trinitrotoluene (TNT) and hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) in ground water and leachate at the Umatilla Army Depot Activity, Hermiston, Oregon and US Naval Submarine Base, Bangor, Washington, Superfund sites. Ground water samples were analyzed by each of the on-site methods and results compared to laboratory analysis using high performance liquid chromatography (HPLC) with EPA SW-846 Method 8330. The commercial methods evaluated include the EnSys, Inc., TNT and RDX colorimetric test kits (EPA SW-846 Methods 8515 and 8510) with amore » solid phase extraction (SPE) step, the DTECH/EM Science TNT and RDX immunoassay test kits (EPA SW-846 Methods 4050 and 4051), and the Ohmicron TNT immunoassay test kit. The emerging methods tested include the antibody-based Naval Research Laboratory (NRL) Continuous Flow Immunosensor (CFI) for TNT and RDX, and the Fiber Optic Biosensor (FOB) for TNT. Accuracy of the on-site methods were evaluated using linear regression analysis and relative percent difference (RPD) comparison criteria. Over the range of conditions tested, the colorimetric methods for TNT and RDX showed the highest accuracy of the emerging methods for TNT and RDX. The colorimetric method was selected for routine ground water monitoring at the Umatilla site, and further field testing on the NRL CFI and FOB biosensors will continue at both Superfund sites.« less

  17. Factor Structure and Gender Stability of the Brazilian Version of the Pornography Consumption Inventory.

    PubMed

    Baltieri, Danilo Antonio; de Oliveira, Vitor Henrique; de Souza Gatti, Ana Luísa; Junqueira Aguiar, Ana Saito; de Souza Aranha E Silva, Renata Almeida

    2016-10-02

    There are a few instruments available to measure pornograhy consumption-related constructs, and this lack of instruments can compromise the validity of research findings. The Pornography Consumption Inventory (PCI) assesses four motivations for pornography consumption, and it has been validated in hypersexual men and medical students. However, whether the psychometric properties of this instrument are comparable across genders remains unclear. Multigroup confirmatory factor analysis (MGCFA) was used to verify the invariance of the structure of the PCI across male (100) and female (105) university students. The confirmatory factor analysis (CFA) for each group showed a reasonably good fit of the data to the four-factor model. The MGCFA model included only factor loadings constrained to be equal between both genders (ΔCFI < 0.01 and p > 0.05). However, the ΔCFI did not support a strong and strict factorial invariance, ΔCFI > 0.01. Although both genders seemed to agree with the conceptualization of pornography and motivations for consuming it, the PCI was not gender-invariant, as men showed a stronger degree of motivation to consume pornographic material than women did. The implications of these findings regarding the measurement of motivations for pornography use are outlined.

  18. Exploring the Measurement Properties of the eHealth Literacy Scale (eHEALS) Among Baby Boomers: A Multinational Test of Measurement Invariance.

    PubMed

    Sudbury-Riley, Lynn; FitzPatrick, Mary; Schulz, Peter J

    2017-02-27

    The eHealth Literacy Scale (eHEALS) is one of only a few available measurement scales to assess eHealth literacy. Perhaps due to the relative paucity of such measures and the rising importance of eHealth literacy, the eHEALS is increasingly a choice for inclusion in a range of studies across different groups, cultures, and nations. However, despite its growing popularity, questions have been raised over its theoretical foundations, and the factorial validity and multigroup measurement properties of the scale are yet to be investigated fully. The objective of our study was to examine the factorial validity and measurement invariance of the eHEALS among baby boomers (born between 1946 and 1964) in the United States, United Kingdom, and New Zealand who had used the Internet to search for health information in the last 6 months. Online questionnaires collected data from a random sample of baby boomers from the 3 countries of interest. The theoretical underpinning to eHEALS comprises social cognitive theory and self-efficacy theory. Close scrutiny of eHEALS with analysis of these theories suggests a 3-factor structure to be worth investigating, which has never before been explored. Structural equation modeling tested a 3-factor structure based on the theoretical underpinning to eHEALS and investigated multinational measurement invariance of the eHEALS. We collected responses (N=996) to the questionnaires using random samples from the 3 countries. Results suggest that the eHEALS comprises a 3-factor structure with a measurement model that falls within all relevant fit indices (root mean square error of approximation, RMSEA=.041, comparative fit index, CFI=.986). Additionally, the scale demonstrates metric invariance (RMSEA=.040, CFI=.984, ΔCFI=.002) and even scalar invariance (RMSEA=.042, CFI=.978, ΔCFI=.008). To our knowledge, this is the first study to demonstrate multigroup factorial equivalence of the eHEALS, and did so based on data from 3 diverse nations and random samples drawn from an increasingly important cohort. The results give increased confidence to researchers using the scale in a range of eHealth assessment applications from primary care to health promotions. ©Lynn Sudbury-Riley, Mary FitzPatrick, Peter J Schulz. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 27.02.2017.

  19. Exploring the Measurement Properties of the eHealth Literacy Scale (eHEALS) Among Baby Boomers: A Multinational Test of Measurement Invariance

    PubMed Central

    2017-01-01

    Background The eHealth Literacy Scale (eHEALS) is one of only a few available measurement scales to assess eHealth literacy. Perhaps due to the relative paucity of such measures and the rising importance of eHealth literacy, the eHEALS is increasingly a choice for inclusion in a range of studies across different groups, cultures, and nations. However, despite its growing popularity, questions have been raised over its theoretical foundations, and the factorial validity and multigroup measurement properties of the scale are yet to be investigated fully. Objective The objective of our study was to examine the factorial validity and measurement invariance of the eHEALS among baby boomers (born between 1946 and 1964) in the United States, United Kingdom, and New Zealand who had used the Internet to search for health information in the last 6 months. Methods Online questionnaires collected data from a random sample of baby boomers from the 3 countries of interest. The theoretical underpinning to eHEALS comprises social cognitive theory and self-efficacy theory. Close scrutiny of eHEALS with analysis of these theories suggests a 3-factor structure to be worth investigating, which has never before been explored. Structural equation modeling tested a 3-factor structure based on the theoretical underpinning to eHEALS and investigated multinational measurement invariance of the eHEALS. Results We collected responses (N=996) to the questionnaires using random samples from the 3 countries. Results suggest that the eHEALS comprises a 3-factor structure with a measurement model that falls within all relevant fit indices (root mean square error of approximation, RMSEA=.041, comparative fit index, CFI=.986). Additionally, the scale demonstrates metric invariance (RMSEA=.040, CFI=.984, ΔCFI=.002) and even scalar invariance (RMSEA=.042, CFI=.978, ΔCFI=.008). Conclusions To our knowledge, this is the first study to demonstrate multigroup factorial equivalence of the eHEALS, and did so based on data from 3 diverse nations and random samples drawn from an increasingly important cohort. The results give increased confidence to researchers using the scale in a range of eHealth assessment applications from primary care to health promotions. PMID:28242590

  20. Cause or Effect of Arteriogenesis: Compositional Alterations of Microparticles from CAD Patients Undergoing External Counterpulsation Therapy

    PubMed Central

    Stutz, Monika; Buchs, Natasha; Heller, Manfred

    2012-01-01

    Recently, a clinical study on patients with stable coronary artery disease (CAD) showed that external counterpulsation therapy (ECP) at high (300 mmHg) but not at low inflation pressure (80 mmHg) promoted coronary collateral growth, most likely due to shear stress-induced arteriogenesis. The exact molecular mechanisms behind shear stress-induced arteriogenesis are still obscure. We therefore characterized plasma levels of circulating microparticles (MPs) from these CAD patients because of their ambivalent nature as a known cardiovascular risk factor and as a promoter of neovascularization in the case of platelet-derived MPs. MPs positive for Annexin V and CD31CD41 were increased, albeit statistically significant (P<0.05, vs. baseline) only in patients receiving high inflation pressure ECP as determined by flow cytometry. MPs positive for CD62E, CD146, and CD14 were unaffected. In high, but not in low, inflation pressure treatment, change of CD31CD41 was inversely correlated to the change in collateral flow index (CFI), a measure for collateral growth. MPs from the high inflation pressure group had a more sustained pro-angiogenic effect than the ones from the low inflation pressure group, with the exception of one patient showing also an increased CFI after treatment. A total of 1005 proteins were identified by a label-free proteomics approach from MPs of three patients of each group applying stringent acceptance criteria. Based on semi-quantitative protein abundance measurements, MPs after ECP therapy contained more cellular proteins and increased CD31, corroborating the increase in MPs. Furthermore, we show that MP-associated factors of the innate immune system were decreased, many membrane-associated signaling proteins, and the known arteriogenesis stimulating protein transforming growth factor beta-1 were increased after ECP therapy. In conclusion, our data show that ECP therapy increases platelet-derived MPs in patients with CAD and that the change in protein cargo of MPs is likely in favor of a pro angiogenic/arteriogenic property. Trial Registration ClinicalTrials.gov NCT00414297 PMID:23056467

  1. Descriptive Characteristics and Amputation Rates With Use of Intrepid Dynamic Exoskeleton Orthosis.

    PubMed

    Hill, Owen; Bulathsinhala, Lakmini; Eskridge, Susan L; Quinn, Kimberly; Stinner, Daniel J

    2016-11-01

    Advancements in ankle-foot orthotic devices, such as the Intrepid Dynamic Exoskeletal Orthosis (IDEO), are designed to improve function and reduce pain of the injured lower extremity. There is a paucity of research detailing the demographics, injury patterns and amputation outcomes of patients who have been prescribed an IDEO. The purpose of this study was to describe the demographics, presenting diagnosis and patterns of amputation in patients prescribed an IDEO at the Center for the Intrepid (CFI). The study population was comprised of 624 service members who were treated at the CFI and prescribed an IDEO between 2009 and 2014. Data were extracted from the Expeditionary Medical Encounter Database, Defense Manpower Data Center, Military Health System Data Repository, and CFI patient records for demographic and injury information as well as an amputation outcome. The most common injury category that received an IDEO prescription was injuries at or surrounding the ankle joint (25.0%), followed by tibia injuries (17.5%) and nerve injuries below the knee (16.4%). Over 80% of the sample avoided amputation within a one year time period using this treatment modality. Future studies should longitudinally track IDEO users for a longer term to determine the long term viability of the device. Reprint & Copyright © 2016 Association of Military Surgeons of the U.S.

  2. Cross-Cultural Validation of the Basic Psychological Needs in Physical Education Scale between Portugal and Brazil Samples.

    PubMed

    Cid, Luis; Lettnin, Carla; Stobäus, Claus; Monteiro, Diogo; Davoglio, Tárcia; Moutão, João

    2016-02-19

    The main propose of this study is the cross-cultural validation of the Basic Psychological Needs in Physical Education Scale among Portugal and Brazil samples, through the study of measurement model invariance. Participated in this study, two independent samples, one with 616 Portuguese students, of the 2nd and 3rd basic grade of public school, aged between 9 and 18 years old and another with 450 Brazilian students, from 1st, 2nd and 3rd middle grade of public and private school, aged between 14 and 18 years old. The results support the suitability of the model (three factors, each one with four items), showing an adequate fit to the data in each sample (Portugal: χ2 = 203.8, p = .001, df = 51, SRMR = .062, NNFI = .926, CFI = .943, RMSEA = .070, RMSEA 90% IC = .060-.080; Brazil: χ2 = 173.7, p = .001, df = 51, SRMR = .052, NNFI = .940, CFI = .954, RMSEA = .073, RMSEA 90% IC = .061-.085), as well valid cross-cultural invariance among Portuguese e Brazilian samples (∆CFI ≤ .01). Those findings allow us to conclude that scale can be used to measure the basic psychological needs in physical education in Portugal and in Brazil.

  3. Training on the DSM-5 Cultural Formulation Interview improves cultural competence in general psychiatry residents: A pilot study.

    PubMed

    Mills, Stacia; Xiao, Anna Q; Wolitzky-Taylor, Kate; Lim, Russell; Lu, Francis G

    2017-04-01

    The objective of this study was to assess whether a 1-hour didactic session on the DSM-5 Cultural Formulation Interview (CFI) improves the cultural competence of general psychiatry residents. The main hypothesis was that teaching adult psychiatry residents a 1-hour session on the CFI would improve cultural competence. The exploratory hypothesis was that trainees with more experience in cultural diversity would have a greater increase in cultural competency scores. Psychiatry residents at a metropolitan, county hospital completed demographics and preintervention questionnaires, were exposed to a 1-hour session on the CFI, and were given a postintervention questionnaire. The questionnaire was an adapted version of the validated Cultural Competence Assessment Tool . Paired samples t tests compared pre- to posttest change. Hierarchical linear regression assessed whether pretraining characteristics predicted posttest scores. The mean change of total pre- and posttest scores was significant ( p = .002), as was the mean change in subscales Nonverbal Communications ( p < .001) and Cultural Knowledge ( p = .002). Demographic characteristics did not predict higher posttest scores (when covarying for pretest scores). Psychiatry residents' cultural competence scores improved irrespective of previous experience in cultural diversity. More research is needed to further explore the implications of the improved scores in clinical practice.

  4. Measurement equivalence across gender and education in the WHOQOL-BREF for community-dwelling elderly Taiwanese.

    PubMed

    Lin, Chung-Ying; Li, Yueh-Ping; Lin, Sang-I; Chen, Ching-Huey

    2016-08-01

    The WHOQOL-BREF, a generic quality of life (QoL) instrument, has been widely used clinically and for research on older populations. However, its measurement equivalence/invariance (ME/I) has not been well examined for the elderly (≥ 65 years) across some different demographics. The data were derived from a cross-sectional study with a convenience sampling design in Taiwan. We enrolled 244 elderly participants: men = 143 (58.6%); educational level ≤ primary school = 121 (49.6%). The ME/I was examined using multiple group confirmatory factor analysis (MGCFA) across gender and educational level. The fit indices were satisfactory for the configural models of gender and educational level (standardized root mean square residual [SRMR] = 0.0742 and 0.0770; root mean square error of approximation [RMSEA] = 0.0655 and 0.0686; comparative fit index [CFI] = 0.953). In addition, MGCFAs showed that ME/I was supported across gender (ΔSRMR = 0.001 to 0.019; ΔRMSEA = -0.003 to 0.001; ΔCFI = -0.003 to 0.000) and educational level (ΔSRMR = 0.002 to 0.006; ΔRMSEA = -0.002 to 0.004; ΔCFI = -0.007 to 0.000). The WHOQOL-BREF Taiwan version is appropriate for combined use and for comparisons in older people across gender and different educational levels.

  5. Frailty Index Developed From a Cancer-Specific Geriatric Assessment and the Association With Mortality Among Older Adults With Cancer.

    PubMed

    Guerard, Emily J; Deal, Allison M; Chang, YunKyung; Williams, Grant R; Nyrop, Kirsten A; Pergolotti, Mackenzi; Muss, Hyman B; Sanoff, Hanna K; Lund, Jennifer L

    2017-07-01

    Background: An objective measure is needed to identify frail older adults with cancer who are at increased risk for poor health outcomes. The primary objective of this study was to develop a frailty index from a cancer-specific geriatric assessment (GA) and evaluate its ability to predict all-cause mortality among older adults with cancer. Patients and Methods: Using a unique and novel data set that brings together GA data with cancer-specific and long-term mortality data, we developed the Carolina Frailty Index (CFI) from a cancer-specific GA based on the principles of deficit accumulation. CFI scores (range, 0-1) were categorized as robust (0-0.2), pre-frail (0.2-0.35), and frail (>0.35). The primary outcome for evaluating predictive validity was all-cause mortality. The Kaplan-Meier method and log-rank tests were used to compare survival between frailty groups, and Cox proportional hazards regression models were used to evaluate associations. Results: In our sample of 546 older adults with cancer, the median age was 72 years, 72% were women, 85% were white, and 47% had a breast cancer diagnosis. Overall, 58% of patients were robust, 24% were pre-frail, and 18% were frail. The estimated 5-year survival rate was 72% in robust patients, 58% in pre-frail patients, and 34% in frail patients (log-rank test, P <.0001). Frail patients had more than a 2-fold increased risk of all-cause mortality compared with robust patients (adjusted hazard ratio, 2.36; 95% CI, 1.51-3.68). Conclusions: The CFI was predictive of all-cause mortality in older adults with cancer, a finding that was independent of age, sex, cancer type and stage, and number of medical comorbidities. The CFI has the potential to become a tool that oncologists can use to objectively identify frailty in older adults with cancer. Copyright © 2017 by the National Comprehensive Cancer Network.

  6. Cryogenic Scanning Tunneling Spectroscopy of Superconducting Iron Chalcogenide Single Crystals

    NASA Astrophysics Data System (ADS)

    Wei, J. Y. T.; Fridman, Igor; Yeh, Kuo-Wei; Wu, Maw-Kuen; Hu, Rongwei; Petrovic, C.

    2011-03-01

    We report scanning tunneling spectroscopy measurements on the iron-based superconductors of the ``11'' family including Fe 1-y Te 1-x Se x and Fe 1-y Te 1-x Sx . Conductance spectra and atomically-resolved images are obtained on single crystals down to 300 mK. A gap-like structure is observed, showing an asymmetric spectral background, non-trivial spatial variation and temperature dependence. We discuss our data in terms of possible gap anisotropy and doping inhomogeneities, and in relation to other recent spectroscopic measurements on iron-based superconductors. Work supported by NSERC, CFI/OIT, CIFAR, Taiwan National Science Council, U.S. DOE and Brookhaven Science Associates (No. DE-Ac02-98CH10886), and in part by the Center for Emergent Superconductivity, an Energy Frontier Research Center.

  7. Practical use of a uterine score system for predicting effects on interval from calving to first insemination and non-return rate 56 in Danish dairy herds.

    PubMed

    Elkjær, Karina; Labouriau, Rodrigo; Ancker, Marie-Louise; Gustafsson, Hans; Callesen, Henrik

    2013-12-01

    A detailed study of 398,237 lactations of Danish Holstein dairy cows was undertaken. The objective was to investigate the information gained by evaluating vaginal discharge in cows from 5 to 19 days post-partum (p.p.) using an ordinal scale from 0 to 9. The study focused on the interval from calving to first insemination (CFI) and the non-return rate 56 days after first insemination (NR56), adjusted for the confounders milk production and body condition score (BCS). For the analyses, BCS was evaluated on the same day that the uterine score was made. Milk production was defined as test-day milk yield in the first month p.p. The study showed that the evaluation of vaginal discharge according to this score system permitted ranking of cows according to CFI and NR56, i.e. an increasing uterine score was associated with a significantly longer time from calving to first insemination and significantly reduced the probability of success of the first insemination. Reproductive success was already affected if the uterine score had reached 4 (i.e. before the discharge smelled abnormally). The negative effect on CFI and NR56 increased as the uterine score increased, which suggested that the uterine scoring system was a useful guide to dairy producers. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. Flame resistant cellulose fiber insulation and process of preparing it

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Quinto, M.J.

    1979-11-06

    This invention produces flame resistant cellulose fiber insulation, which will be referred to as CFI. The best flameproofing agents which have been used in the past are mixtures of boric acid and borax as the major portion of the mix and have been applied both as dry powders and sprayed from water dispersions. Boric acid is quite expensive as it is prepared from borax by the addition of acid and purification of the boric acid. In the present invention lower cost materials and process are obtained by applying a mixture of boric acid and borax which has been prepared bymore » adding acid, such as sulfuric acid, a mixture of sulfuric and phosphoric acid, and the like, to borax to transform a portion of the borax into boric acid. The reaction products, sodium sulfate, or a mixture of sodium sulfate and sodium phosphate in the case both acids are used, remain in the material applied to CFI. While they are not by themselves highly effective flameproofing agents, particularly sodium sulfate is not, they do add somewhat to flame resistance. In other words, wht elimination of the step of separating and/or purifying boric acid is eliminated without, however, eliminating its function. The product produced is as good a flame retarder when applied to CFI; in fact it is slightly better. Additionally there are great savings in cost.« less

  9. A hypervariable STR polymorphism in the CFI gene: southern origin of East Asian-specific group H alleles.

    PubMed

    Yuasa, Isao; Jin, Feng; Harihara, Shinji; Matsusue, Aya; Fujihara, Junko; Takeshita, Haruo; Akane, Atsushi; Umetsu, Kazuo; Saitou, Naruya; Chattopadhyay, Prasanta K

    2013-09-01

    Previous studies of four populations revealed that a hypervariable short tandem repeat (iSTR) in intron 7 of the human complement factor I (CFI) gene on chromosome 4q was unique, with 17 possible East Asian-specific group H alleles observed at relatively high frequencies. To develop a deeper anthropological and forensic understanding of iSTR, 1161 additional individuals from 11 Asian populations were investigated. Group H alleles of iSTR and c.1217A allele of a SNP in exon 11 of the CFI gene were associated with each other and were almost entirely confined to East Asian populations. Han Chinese in Changsha, southern China, showed the highest frequency for East Asian-specific group H alleles (0.201) among 15 populations. Group H alleles were observed to decrease gradually from south to north in 11 East Asian populations. This expansion of group H alleles provides evidence that southern China and Southeast Asia are a hotspot of Asian diversity and a genetic reservoir of Asians after they entered East Asia. The expected heterozygosity values of iSTR ranged from 0.927 in Thais to 0.874 in Oroqens, higher than those of an STR in the fibrinogen alpha chain (FGA) gene on chromosome 4q. Thus, iSTR is a useful marker for anthropological and forensic genetics. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  10. Characterization of Arabidopsis sterol glycosyltransferase TTG15/UGT80B1 role during freeze and heat stress

    PubMed Central

    Mishra, Manoj K; Singh, Gaurav; Tiwari, Shalini; Singh, Ruchi; Kumari, Nishi; Misra, Pratibha

    2015-01-01

    Sterol glycosyltransferases regulate the properties of sterols by catalyzing the transfer of carbohydrate molecules to the sterol moiety for the synthesis of steryl glycosides and acyl steryl glycosides. We have analyzed the functional role of TTG15/UGT80B1 gene of Arabidopsis thaliana in freeze/thaw and heat shock stress using T-DNA insertional sgt knockout mutants. Quantitative study of spatial as well as temporal gene expression showed tissue-specific and dynamic expression patterns throughout the growth stages. Comparative responses of Col-0, TTG15/UGT80B1 knockout mutant and p35S:TTG15/UGT80B1 restored lines were analyzed under heat and freeze stress conditions. Heat tolerance was determined by survival of plants at 42°C for 3 h, MDA analysis and chlorophyll fluorescence image (CFI) analysis. Freezing tolerance was determined by survival of the plants at -1°C temperature in non-acclimatized (NA) and cold acclimatized (CA) conditions and also by CFI analysis, which revealed that, p35S:TTG15/UGT80B1 restored plants were more adapted to freeze stress than TTG15/UGT80B1 knockout mutant under CA condition. HPLC analysis of the plants showed reduced sterol glycoside in mutant seedlings as compared to other genotypes. Following CA condition, both β-sitosterol and sitosterol glycoside quantity was more in Col-0 and p35S:TTG15/UGT80B1 restored lines, whereas it was significantly less in TTG15/UGT80B1 knockout mutants. From these results, it may be concluded that due to low content of free sterols and sterol glycosides, the physiology of mutant plants was more affected during both, the chilling and heat stress. PMID:26382564

  11. Multiple mobile promoter regions for the rare carbapenem resistance gene of Bacteroides fragilis.

    PubMed

    Podglajen, I; Breuil, J; Rohaut, A; Monsempes, C; Collatz, E

    2001-06-01

    Two novel insertion sequences (IS), IS1187 and IS1188, are described upstream from the carbapenem resistance gene cfiA in strains of Bacteroides fragilis. Mapping, with the RACE procedure, of transcription start sites of cfiA in these and two other previously reported IS showed that transcription of this rarely encountered gene is initiated close to a variety of B. fragilis consensus promoter sequences, as recently defined (D. P. Bayley, E. R. Rocha, and C. J. Smith, FEMS Microbiol. Lett. 193:149-154, 2000). In the cases of IS1186 and IS1188, these sequences overlap with putative Esigma(70) promoter sequences, while in IS942 and IS1187 such sequences can be observed either upstream or downstream of the B. fragilis promoters.

  12. High Serum sTREM-1 Correlates With Myocardial Dysfunction and Predicts Prognosis in Septic Patients.

    PubMed

    Li, Zhenyu; Zhang, Enyuan; Hu, Yipeng; Liu, Yi; Chen, Bing

    2016-06-01

    This study aimed to evaluate the predictive and prognostic value of soluble triggering receptor expressed on myeloid cells-1 (sTREM-1) in patients with myocardial dysfunction induced by severe sepsis and septic shock. A total of 84 patients with severe sepsis and septic shock were enrolled between May 2013 and December 2014.The patients were monitored by pulse indicator continuous cardiac output system and divided into myocardial depression group (cardiac function index [CFI] < 4.1/minute, n = 37) and nonmyocardial depression group (CFI ≥ 4.1/minute, n = 47 ). Additionally, the patients were divided into survival group (n = 40) and nonsurvival group (n = 44) based on 28-day mortality. Hemodynamic parameters and serum sTREM-1, B-type natriuretic peptide (BNP) and cardiac troponin I (cTnI) levels were collected on days 1, 3 and 5 after admission to intensive care unit. (1) The serum values of sTREM-1, BNP and cTnI in myocardial depression group were higher than those in nonmyocardial depression group (P < 0.01); and CFI, cardiac index, stroke volume, global ejection fraction and left ventricular contractility index (dpmax) in myocardial depression group were lower than those in nonmyocardial depression group on day 1 (P < 0.05); (2) serum sTREM-1 negatively correlated with left ventricular ejection fraction, CFI, cardiac index, global ejection fraction and dpmax, and it positively correlated with BNP and cTnI (P < 0.01); (3) the area under the receiver operating characteristics curve for sTREM-1 in the prediction of myocardial depression was 0.671 with a sensitivity of 83.8% and a specificity of 46.8% when cutoff point was 174.5ng/mL, the power of predicting septic depression for sTREM-1 was lower than that of BNP; logistic regression analysis showed that serum sTREM-1 was not an independent predictor of septic myocardial depression; the area under the receiver operating characteristics curve was 0.773 for sTREM-1 in predicting outcome with a sensitivity of 86.4% and a specificity of 80% when cutoff point was 182.3ng/mL, the power of predicting prognosis for sTREM-1 was superior to those of BNP and cTnI; (4) there was a decrease trend for sTREM-1 levels and an increasing trend for CFI in the survival group (P < 0.05). Myocardial dysfunction is common in patients with severe sepsis and septic shock and high serum levels of sTREM-1 correlates with myocardial dysfunction to some extent but is not an independent predictor, which more importantly showed prognostic value for septic shock outcome. Copyright © 2016 Southern Society for Clinical Investigation. Published by Elsevier Inc. All rights reserved.

  13. An Evaluation of Training Interventions and Computed Scoring Techniques for Grading a Level Turn Task and a Straight In Landing Approach on a PC-Based Flight Simulator

    NASA Technical Reports Server (NTRS)

    Heath, Bruce E.

    2007-01-01

    One result of the relatively recent advances in computing technology has been the decreasing cost of computers and increasing computational power. This has allowed high fidelity airplane simulations to be run on personal computers (PC). Thus, simulators are now used routinely by pilots to substitute real flight hours for simulated flight hours for training for an aircraft type rating thereby reducing the cost of flight training. However, FAA regulations require that such substitution training must be supervised by Certified Flight Instructors (CFI). If the CFI presence could be reduced or eliminated for certain tasks this would mean a further cost savings to the pilot. This would require that the flight simulator have a certain level of 'intelligence' in order to provide feedback on pilot perfolmance similar to that of a CFI. The 'intelligent' flight sinlulator would have at least the capability to use data gathered from the flight to create a measure for the performance of the student pilot. Also, to fully utilize the advances in computational power, the sinlulator would be capable of interacting with the student pilot using the best possible training interventions. This thesis reposts on the two studies conducted at Tuskegee University investigating the effects of interventions on the learning of two flight maneuvers on a flight sinlulator and the robustness and accuracy of calculated perfornlance indices as compared to CFI evaluations of performance. The intent of these studies is to take a step in the direction of creating an 'intelligent' flight simulator. The first study deals with the comparisons of novice pilot performance trained at different levels of above real-time to execute a level S-turn. The second study examined the effect of out-of-the-window (OTW) visual cues in the form of hoops on the performance of novice pilots learning to fly a landing approach on the flight simulator. The reliability/robustness of the computed performance metrics was assessed by comparing them with the evaluations of the landing approach maneuver by a number of CFIs.

  14. Development and Assessment of a Novel Training Package for Basic Maneuvering Tasks on a Flight Simulator Using Self Instruction Methods and Above Real Time Training (ARTT)

    NASA Technical Reports Server (NTRS)

    Ali, Syed Firasat; Khan, M. Javed; Rossi, Marcia J.; Heath, Bruce e.; Crane, Peter; Ward, Marcus; Crier, Tomyka; Knighten, Tremaine; Culpepper, Christi

    2007-01-01

    One result of the relatively recent advances in computing technology has been the decreasing cost of computers and increasing computational power. This has allowed high fidelity airplane simulations to be run on personal computers (PC). Thus, simulators are now used routinely by pilots to substitute real flight hours for simulated flight hours for training for an aircraft type rating thereby reducing the cost of flight training. However, FAA regulations require that such substitution training must be supervised by Certified Flight Instructors (CFI). If the CFI presence could be reduced or eliminated for certain tasks this would mean a further cost savings to the pilot. This would require that the flight simulator have a certain level of 'intelligence' in order to provide feedback on pilot performance similar to that of a CFI. The 'intelligent' flight simulator would have at least the capability to use data gathered from the flight to create a measure for the performance of the student pilot. Also, to fully utilize the advances in computational power, the simulator would be capable of interacting with the student pilot using the best possible training interventions. This thesis reports on the two studies conducted at Tuskegee University investigating the effects of interventions on the learning of two flight maneuvers on a flight simulator and the robustness and accuracy of calculated performance indices as compared to CFI evaluations of performance. The intent of these studies is to take a step in the direction of creating an 'intelligent' flight simulator. The first study deals with the comparisons of novice pilot performance trained at different levels of above real-time to execute a level S-turn. The second study examined the effect of out-of-the-window (OTW) visual cues in the form of hoops on the performance of novice pilots learning to fly a landing approach on the flight simulator. The reliability/robustness of the computed performance metrics was assessed by comparing them with the evaluations of the landing approach maneuver by a number of CFIs.

  15. [Hyperspectral Remote Sensing Estimation Models for Pasture Quality].

    PubMed

    Ma, Wei-wei; Gong, Cai-lan; Hu, Yong; Wei, Yong-lin; Li, Long; Liu, Feng-yi; Meng, Peng

    2015-10-01

    Crude protein (CP), crude fat (CFA) and crude fiber (CFI) are key indicators for evaluation of the quality and feeding value of pasture. Hence, identification of these biological contents is an essential practice for animal husbandry. As current approaches to pasture quality estimation are time-consuming and costly, and even generate hazardous waste, a real-time and non-destructive method is therefore developed in this study using pasture canopy hyperspectral data. A field campaign was carried out in August 2013 around Qinghai Lake in order to obtain field spectral properties of 19 types of natural pasture using the ASD Field Spec 3, a field spectrometer that works in the optical region (350-2 500 nm) of the electromagnetic spectrum. In additional to the spectral data, pasture samples were also collected from the field and examined in laboratory to measure the relative concentration of CP (%), CFA (%) and CFI (%). After spectral denoising and smoothing, the relationship of pasture quality parameters with the reflectance spectrum, the first derivatives of reflectance (FDR), band ratio and the wavelet coefficients (WCs) was analyzed respectively. The concentration of CP, CFA and CFI of pasture was found closely correlated with FDR with wavebands centered at 424, 1 668, and 918 nm as well as with the low-scale (scale = 2, 4) Morlet, Coiflets and Gassian WCs. Accordingly, the linear, exponential, and polynomial equations between each pasture variable and FDR or WCs were developed. Validation of the developed equations indicated that the polynomial model with an independent variable of Coiflets WCs (scale = 4, wavelength =1 209 nm), the polynomial model with an independent variable of FDR, and the exponential model with an independent variable of FDR were the optimal model for prediction of concentration of CP, CFA and CFI of pasture, respectively. The R2 of the pasture quality estimation models was between 0.646 and 0.762 at the 0.01 significance level. Results suggest that the first derivatives or the wavelet coefficients of hyperspectral reflectance in visible and near-infrared regions can be used for pasture quality estimation, and that it will provide a basis for real-time prediction of pasture quality using remote sensing techniques.

  16. Cross-cultural adaptation of the Health Education Impact Questionnaire: experimental study showed expert committee, not back-translation, added value.

    PubMed

    Epstein, Jonathan; Osborne, Richard H; Elsworth, Gerald R; Beaton, Dorcas E; Guillemin, Francis

    2015-04-01

    To assess the contribution of back-translation and expert committee to the content and psychometric properties of a translated multidimensional questionnaire. Recommendations for questionnaire translation include back-translation and expert committee, but their contribution to measurement properties is unknown. Four English to French translations of the Health Education Impact Questionnaire were generated with and without committee or back-translation. Face validity, acceptability, and structural properties were compared after random assignment to people with rheumatoid arthritis (N = 1,168), chronic renal failure (N = 2,368), and diabetes (N = 538). For face validity, 15 bilingual people compared translations quality with the original. Psychometric properties were examined using confirmatory factor analysis (metric and scalar invariance) and item response theory. Qualitatively, there were five types of translation errors: style, intensity, frequency/time frame, breadth, and meaning. Bilingual assessors ranked best the translations with committee (P = 0.0026). All translations had good structural properties (root mean square error of approximation <0.05; comparative fit index [CFI], ≥0.899; and Tucker-Lewis index, ≥0.889). Full measurement invariance was observed between translations (ΔCFI ≤ 0.01) with metric invariance between translations and original (lowest ΔCFI = 0.022 between fully constrained models and models with free intercepts). Item characteristic curve analyses revealed no significant differences. This is the first experimental evidence that back-translation has moderate impact, whereas expert committee helps to ensure accurate content. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Confirmatory factor analysis reveals a latent cognitive structure common to bipolar disorder, schizophrenia, and normal controls.

    PubMed

    Schretlen, David J; Peña, Javier; Aretouli, Eleni; Orue, Izaskun; Cascella, Nicola G; Pearlson, Godfrey D; Ojeda, Natalia

    2013-06-01

    We sought to determine whether a single hypothesized latent factor structure would characterize cognitive functioning in three distinct groups. We assessed 576 adults (340 community controls, 126 adults with bipolar disorder, and 110 adults with schizophrenia) using 15 measures derived from nine cognitive tests. Confirmatory factor analysis (CFA) was conducted to examine the fit of a hypothesized six-factor model. The hypothesized factors included attention, psychomotor speed, verbal memory, visual memory, ideational fluency, and executive functioning. The six-factor model provided an excellent fit for all three groups [for community controls, root mean square error of approximation (RMSEA) <0.048 and comparative fit index (CFI) = 0.99; for adults with bipolar disorder, RMSEA = 0.071 and CFI = 0.99; and for adults with schizophrenia, RMSEA = 0.06 and CFI = 0.98]. Alternate models that combined fluency with processing speed or verbal and visual memory reduced the goodness of fit. Multi-group CFA results supported factor invariance across the three groups. Confirmatory factor analysis supported a single six-factor structure of cognitive functioning among patients with schizophrenia or bipolar disorder and community controls. While the three groups clearly differ in level of performance, they share a common underlying architecture of information processing abilities. These cognitive factors could provide useful targets for clinical trials of treatments that aim to enhance information processing in persons with neurological and neuropsychiatric disorders. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Argentine Space Assets.

    DTIC Science & Technology

    1997-09-01

    Interview, December 1996. Perea, Mauricio, La CFI Invierte En La Empresa Encargada De Las Comunicaciones Por Satelite En Argentina. Corporacion Financiera...1 Attn: Servicio de Comunicaciones Navales 630 Indiana Avenue NW Washington, D.C. 20004-2989 13. A rgentine N

  19. 40 CFR 86.413-2006 - Labeling.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... lettered in the English language in block letters and numerals, which shall be of a color that contrasts...; DFI Direct fuel injection; O2S Oxygen sensor; HO2S Heated oxygen sensor; EM Engine modification; CFI...

  20. 40 CFR 86.413-2006 - Labeling.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... lettered in the English language in block letters and numerals, which shall be of a color that contrasts...; DFI Direct fuel injection; O2S Oxygen sensor; HO2S Heated oxygen sensor; EM Engine modification; CFI...

  1. Imaging of fast chlorophyll fluorescence induction curve (OJIP) parameters, applied in a screening study with wild barley (Hordeum spontaneum) genotypes under heat stress.

    PubMed

    Jedmowski, Christoph; Brüggemann, Wolfgang

    2015-10-01

    We quantified the influence of heat stress (HS) on PSII by imaging of parameters of the fast chlorophyll fluorescence (CF) induction (OJIP) kinetic of 20 genotypes of wild barley (Hordeum spontaneum) covering a broad geographical spectrum. We developed a standardised screening procedure, allowing a repetitive fluorescence measurement of leaf segments. The impact of HS was quantified by calculating a Heat Resistance Index (HRI), derived from the decrease of the Performance Index (PI) caused by HS treatment and following recovery. For the genotype showing the lowest HRI, reduced maximum quantum yield (φP0) and increased relative variable fluorescence of the O-J phase (K-Peak) were detected after HS, whereas the basal fluorescence (F0) remained stable. An additional feature was a lowered fraction of active (QA-reducing) reaction centres (RCs). The disturbances disappeared after one day of recovery. Spatial heterogeneities of fluorescence parameters were detected, as the negative effect of HS was stronger in the leaf areas close to the leaf tip. The results of this study prove that chlorophyll fluorescence imaging (CFI) is suitable for the detection of HS symptoms and that imaging of JIP-Test parameters should be considered in future screening and phenotyping studies aiming for the characterisation of plant genotypes. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Exercise-induced ischemia initiates the second window of protection in humans independent of collateral recruitment.

    PubMed

    Lambiase, Pier D; Edwards, Richard J; Cusack, Michael R; Bucknall, Clifford A; Redwood, Simon R; Marber, Michael S

    2003-04-02

    This study was designed to examine if exercise-induced ischemia initiated late preconditioning in humans that becomes manifest during subsequent exercise and serial balloon occlusion of the left anterior descending coronary artery (LAD). The existence of late preconditioning in humans is controversial. We therefore compared myocardial responses to exercise-induced and intracoronary balloon inflation-induced ischemia in two groups of patients subjected to different temporal patterns of ischemia. Thirty patients with stable angina secondary to single-vessel LAD disease underwent percutaneous coronary intervention (PCI) after two separate exercise tolerance test (ETT) protocols designed to investigate isolated early preconditioning (IEP) alone or the second window of protection (SWOP). The IEP subjects underwent three sequential ETTs at least two weeks before PCI. The SWOP subjects underwent five sequential ETTs commencing 24 h before PCI. During PCI there was no significant difference in intracoronary pressure-derived collateral flow index (CFI) between groups (IEP = 0.15 +/- 0.13, SWOP = 0.19 +/- 0.15). In SWOP patients, compared with the initial ETT, the ETT performed 24 h later had a 40% (p < 0.001) increase in time to 0.1-mV ST depression and a 60% (p < 0.05) decrease in ventricular ectopic frequency. During the first balloon inflation, peak ST elevation was reduced by 49% (p < 0.05) in the SWOP versus the IEP group, and the dependence on CFI observed in the IEP group was abolished (analysis of covariance, p < 0.05). The significant attenuation of ST elevation (47%, p < 0.005) seen at the time of the second inflation in the IEP patients was not seen in the SWOP patients. Exercise-induced ischemia triggers late preconditioning in humans, which becomes manifest during exercise and PCI. This is the first evidence that ischemia induced by coronary occlusion is attenuated in humans by a late preconditioning effect induced by exercise.

  3. Closed flume inlet efficiency.

    DOT National Transportation Integrated Search

    2014-04-01

    The goal of the present study was to determine the efficiency of a specific culvert geometry, labeled as : Index 216 Closed Flume Inlet (CFI) in the FDOTs Design Standards, and to determine if geometric changes : affect the efficiency of the curre...

  4. A probability approach to sawtimber tree-value projections

    Treesearch

    Roger E. McCay; Paul S. DeBald; Paul S. DeBald

    1973-01-01

    The authors present a method for projecting hardwood sawtimber tree values, using tree-development probabilities based on continuous forest inventory (CFI) data and describe some ways to use the resulting value projections to assemble management-planning information.

  5. Prevalence of dental fluorosis in relation with different fluoride levels in drinking water among school going children in Sarada tehsil of Udaipur district, Rajasthan.

    PubMed

    Sarvaiya, B U; Bhayya, D; Arora, R; Mehta, D N

    2012-01-01

    To estimate the prevalence of dental fluorosis in relation with different fluoride levels in drinking water among school going children of 6-12 years age group. Dental fluorosis was recorded using Dean's index in school children of selected villages. The drinking water samples of all the selected villages were collected in polyethylene bottles and the fluoride content of these samples was determined by fluoride ion selective method using Orion microprocessor analyser. The overall prevalence of dental fluorosis was found to be 69.84%. An increase in the community fluorosis index (CFI) with corresponding increase in water fluoride content was found. There was an increase in prevalence of dental fluorosis with a corresponding increase in water fluoride content from 0.8 ppm to 4.1 ppm. A significantly strong positive correlation was found between CFI and fluoride concentration in drinking water.

  6. The parental attitudes toward psychological services inventory: adaptation and development of an attitude scale.

    PubMed

    Turner, Erlanger A

    2012-08-01

    The purpose of this paper is to provide psychometric data on the Parental Attitudes Toward Psychological Services Inventory (PATPSI), which is a revised measure to assess parents' attitudes toward outpatient mental health services. Using a sample of adults (N = 250), Study 1 supported a 3-factor structure (RMSEA = .05, NNFI = .94, and CFI = .94), adequate internal consistency (ranging from .72 to .92), and test-retest reliability (ranging from .66 to .84). Additionally, results indicated that individuals with previous use of mental health services reported more positive views toward child mental health services. Study 2 provided confirming evidence of the 3-factor structure (NNFI = .94, RMSEA = .08, and the CFI = .95) and adequate reliability (ranging from .70 to .90) using a parent-sample (N = 260). Additionally, discriminate validity of the PATPSI was supported. Implications for research and clinical practice are discussed.

  7. Measuring burden in dementia caregivers: Confirmatory factor analysis for short forms of the Zarit Burden Interview.

    PubMed

    Lin, Chung-Ying; Wang, Jung-Der; Pai, Ming-Chyi; Ku, Li-Jung Elizabeth

    To examine the psychometric properties of different short versions of the Zarit Burden Interview (ZBI), and to find an efficient and valid short version for clinical use among dementia caregivers. A total of 270 Taiwanese dementia caregivers filled out the full form of the ZBI, which contains 22 items. Using the 22-item ZBI, we used confirmatory factor analysis (CFA) to calculate the fit indices of all proposed short versions with various items to determine useful short versions. Additional associations between each useful short version and informal care hours, as well as subjective financial situations, were examined to understand their concurrent validity. Based on the CFA results, three short versions of the ZBI, performed excellently (4-item version: comparative fit index [CFI]=1.000, Tucker-Lewis index [TLI]=1.035, standardized root mean square residual [SRMR]=0.019, and root mean square error of approximation [RMSEA]=0.000; 8-item version: CFI=0.970, TLI=0.958, SRMR=0.045, and RMSEA=0.065; 12-item version: CFI=0.959, TLI=0.950, SRMR=0.053, and RMSEA=0.075). In addition, the 12-item ZBI, as compared with other versions, had a higher correlation with the number of informal care hours. The 12-item ZBI was also highly correlated with the original 22-item ZBI (r=0.952). We found the 12-item ZBI to be a promising measure for healthcare providers to assess the burden of dementia caregivers quickly and efficiently. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  8. The impact of education, country, race and ethnicity on the self-report of postpartum depression using the Edinburgh Postnatal Depression Scale

    PubMed Central

    Di Florio, A.; Putnam, K.; Altemus, M.; Apter, G.; Bergink, V.; Bilszta, J.; Brock, R.; Buist, A.; Deligiannidis, K. M.; Devouche, E.; Epperson, C. N.; Guille, C.; Kim, D.; Lichtenstein, P.; Magnusson, P. K. E.; Martinez, P.; Munk-Olsen, T.; Newport, J.; Payne, J.; Penninx, B. W.; O’Hara, M.; Robertson-Blackmore, E.; Roza, S. J.; Sharkey, K. M.; Stuart, S.; Tiemeier, H.; Viktorin, A.; Schmidt, P. J.; Sullivan, P. F.; Stowe, Z. N.; Wisner, K. L.; Jones, I.; Rubinow, D. R.; Meltzer-Brody, S.

    2017-01-01

    Background Universal screening for postpartum depression is recommended in many countries. Knowledge of whether the disclosure of depressive symptoms in the postpartum period differs across cultures could improve detection and provide new insights into the pathogenesis. Moreover, it is a necessary step to evaluate the universal use of screening instruments in research and clinical practice. In the current study we sought to assess whether the Edinburgh Postnatal Depression Scale (EPDS), the most widely used screening tool for postpartum depression, measures the same underlying construct across cultural groups in a large international dataset. Method Ordinal regression and measurement invariance were used to explore the association between culture, operationalized as education, ethnicity/race and continent, and endorsement of depressive symptoms using the EPDS on 8209 new mothers from Europe and the USA. Results Education, but not ethnicity/race, influenced the reporting of postpartum depression [difference between robust comparative fit indexes (Δ*CFI) < 0.01]. The structure of EPDS responses significantly differed between Europe and the USA (Δ*CFI > 0.01), but not between European countries (Δ*CFI < 0.01). Conclusions Investigators and clinicians should be aware of the potential differences in expression of phenotype of postpartum depression that women of different educational backgrounds may manifest. The increasing cultural heterogeneity of societies together with the tendency towards globalization requires a culturally sensitive approach to patients, research and policies, that takes into account, beyond rhetoric, the context of a person’s experiences and the context in which the research is conducted. PMID:27866476

  9. Psychometrically Improved, Abbreviated Versions of Three Classic Measures of Impulsivity and Self-Control

    PubMed Central

    Morean, Meghan E.; DeMartini, Kelly S.; Leeman, Robert F.; Pearlson, Godfrey D.; Anticevic, Alan; Krishnan-Sarin, Suchitra; Krystal, John H.; O’Malley, Stephanie S.

    2014-01-01

    Self-reported impulsivity confers risk factor for substance abuse. However, the psychometric properties of many self-report impulsivity measures have been questioned, thereby undermining the interpretability of study findings using these measures. To better understand these measurement limitations and to suggest a path to assessing self-reported impulsivity with greater psychometric stability, we conducted a comprehensive psychometric evaluation of the Barratt Impulsiveness Scale-11 (BIS-11), the Behavioral Inhibition and Activation Scales (BIS/BAS), and the Brief Self Control Scale (BSCS) using data from 1,449 individuals who participated in substance use research. For each measure, we evaluated: 1) latent factor structure, 2) measurement invariance, 3) test-criterion relationships between the measures, and 4) test-criterion relations with drinking and smoking outcomes. Notably, we could not replicate the originally published latent structure for the BIS, BIS/BAS, or BSCS or any previously published alternative factor structures (English language). Using exploratory and confirmatory factor analysis, we identified psychometrically improved, abbreviated versions of each measure (i.e., 8-item, 2 factor BIS-11 [RMSEA = .06, CFI = .95]; 13-item, 4 factor BIS/BAS [RMSEA = .04, CFI = .96]; 7-item, 2 factor BSCS [RMSEA = .05, CFI = .96]). These versions evidenced: 1) stable, replicable factor structures, 2) scalar measurement invariance, ensuring our ability to make statistically interpretable comparisons across subgroups of interest (e.g., sex, race, drinking/smoking status), and 3) test-criterion relationships with each other and with drinking/smoking. This study provides strong support for using these psychometrically improved impulsivity measures, which improve data quality directly through better scale properties and indirectly through reducing response burden. PMID:24885848

  10. Evaluation of pigment epithelium-derived factor and complement factor I polymorphisms as a cause of choroidal neovascularization in highly myopic eyes.

    PubMed

    Miyake, Masahiro; Yamashiro, Kenji; Nakanishi, Hideo; Nakata, Isao; Akagi-Kurashige, Yumiko; Kumagai, Kyoko; Oishi, Maho; Tsujikawa, Akitaka; Moriyama, Muka; Ohno-Matsui, Kyoko; Mochizuki, Manabu; Yoshimura, Nagahisa

    2013-06-19

    A case-control study in a relatively large cohort of highly myopic patients was conducted to explore the genetic background of the occurrence of choroidal neovascularization (CNV) secondary to high myopia. We evaluated three single nucleotide polymorphisms (SNPS) from two candidate genes: pigment epithelium-derived factor (PEDF) and complement factor I (CFI). The SNPs were selected based on previous reports. A total of 1082 unrelated highly myopic (i.e., axial length ≥ 26 mm in at least one eye) Japanese individuals with CNV (n = 478) and without CNV (n = 557) who were 50 years of age and older were genotyped by using an SNP assay. Multivariable logistic regression was conducted to adjust for age, sex, and axial length. compared with individuals without CNV, subjects with CNV were significantly older (P 0.01) and more likely to be female (P 0.01), but they did not have a significantly different axial length (P = 0.50). We did not find an association between the three SNPS and the occurrence of CNV. However, a subanalysis using extremely myopic patients (case: control = 284:317) revealed a marginal association of rs12603825 in the PEDF gene (P = 0.045). The contribution of rs1136287 in CFI was not found in any analysis. We demonstrated a marginal association of the PEDF SNP, rs12603825, with myopic CNV in extremely myopic patients. A further study using a larger cohort might elucidate a significant association; rs1136287 in CFI is less likely to be associated in Japanese individuals.

  11. Development and psychometric characteristics of the SCI-QOL Bladder Management Difficulties and Bowel Management Difficulties item banks and short forms and the SCI-QOL Bladder Complications scale.

    PubMed

    Tulsky, David S; Kisala, Pamela A; Tate, Denise G; Spungen, Ann M; Kirshblum, Steven C

    2015-05-01

    To describe the development and psychometric properties of the Spinal Cord Injury--Quality of Life (SCI-QOL) Bladder Management Difficulties and Bowel Management Difficulties item banks and Bladder Complications scale. Using a mixed-methods design, a pool of items assessing bladder and bowel-related concerns were developed using focus groups with individuals with spinal cord injury (SCI) and SCI clinicians, cognitive interviews, and item response theory (IRT) analytic approaches, including tests of model fit and differential item functioning. Thirty-eight bladder items and 52 bowel items were tested at the University of Michigan, Kessler Foundation Research Center, the Rehabilitation Institute of Chicago, the University of Washington, Craig Hospital, and the James J. Peters VA Medical Center, Bronx, NY. Seven hundred fifty-seven adults with traumatic SCI. The final item banks demonstrated unidimensionality (Bladder Management Difficulties CFI=0.965; RMSEA=0.093; Bowel Management Difficulties CFI=0.955; RMSEA=0.078) and acceptable fit to a graded response IRT model. The final calibrated Bladder Management Difficulties bank includes 15 items, and the final Bowel Management Difficulties item bank consists of 26 items. Additionally, 5 items related to urinary tract infections (UTI) did not fit with the larger Bladder Management Difficulties item bank but performed relatively well independently (CFI=0.992, RMSEA=0.050) and were thus retained as a separate scale. The SCI-QOL Bladder Management Difficulties and Bowel Management Difficulties item banks are psychometrically robust and are available as computer adaptive tests or short forms. The SCI-QOL Bladder Complications scale is a brief, fixed-length outcomes instrument for individuals with a UTI.

  12. The Eating Motivation Survey: results from the USA, India and Germany.

    PubMed

    Sproesser, Gudrun; Ruby, Matthew B; Arbit, Naomi; Rozin, Paul; Schupp, Harald T; Renner, Britta

    2018-02-01

    Research has shown that there is a large variety of different motives underlying why people eat what they eat, which can be assessed with The Eating Motivation Survey (TEMS). The present study investigates the consistency and measurement invariance of the fifteen basic motives included in TEMS in countries with greatly differing eating environments. The fifteen-factor structure of TEMS (brief version: forty-six items) was tested in confirmatory factor analyses. An online survey was conducted. US-American, Indian and German adults (total N 749) took part. Despite the complexity of the model, fit indices indicated a reasonable model fit (for the total sample: χ 2/df=4·03; standardized root-mean-squared residual (SRMR)=0·063; root-mean-square error of approximation (RMSEA)=0·064 (95 % CI 0·062, 0·066)). Only the comparative fit index (CFI) was below the recommended threshold (for the total sample: CFI=0·84). Altogether, 181 out of 184 item loadings were above the recommended threshold of 0·30. Furthermore, the factorial structure of TEMS was invariant across countries with respect to factor configuration and factor loadings (configural v. metric invariance model: ΔCFI=0·009; ΔRMSEA=0·001; ΔSRMR=0·001). Moreover, forty-three out of forty-six items showed invariant intercepts across countries. The fifteen-factor structure of TEMS was, in general, confirmed across countries despite marked differences in eating environments. Moreover, latent means of fourteen out of fifteen motive factors can be compared across countries in future studies. This is a first step towards determining generalizability of the fifteen basic eating motives of TEMS across eating environments.

  13. Measurement equivalence of the newly developed Quality of Life in Childhood Epilepsy Questionnaire (QOLCE-55).

    PubMed

    Ferro, Mark A; Goodwin, Shane W; Sabaz, Mark; Speechley, Kathy N

    2016-03-01

    The aim of this study was to examine measurement equivalence of the newly developed Quality of Life in Childhood Epilepsy Questionnaire (QOLCE-55) across age, sex, and time in a representative sample of children with newly diagnosed epilepsy. Data come from 373 children enrolled in the Health-related Quality of Life in Children with Epilepsy Study (HERQULES), a multisite prospective cohort study. Measurement equivalence was examined using a multiple-group confirmatory factor analysis framework, whereby increasingly stringent parameter constraints are imposed on the model. Comparison groups were stratified based on age (4-7 years vs. 8-12 years), sex (male vs. female), and time (measurement of health-related quality of life at diagnosis vs. 24 months later). The QOLCE-55 demonstrated measurement equivalence at the level of strict invariance for each model tested--age: χ(2) (3,123) = 4,097.3, p < 0.001; Comparative Fit Index (CFI) = 0.968; Root Mean Square Error of Approximation (RMSEA) = 0.042 (0.038, 0.045); sex: χ(2) (3,124) = 4,188.3, p < 0.001; CFI = 0.964; RMSEA = 0.044 (0.040, 0.047); and time: χ(2) (3,121) = 5,185.0, p < 0.001; CFI = 0.965; RMSEA = 0.046 (0.043, 0.048). These findings suggest that items comprising the QOLCE-55 are perceived similarly among groups stratified by age, sex, and time and provide further evidence supporting the validity of the scale in children with epilepsy. Health professionals and researchers should be confident that group comparisons made using the QOLCE-55 are unbiased and that any group differences detected are meaningful; that is, not related to differences in the interpretation of items by informants. Future research replicating these findings is encouraged. Wiley Periodicals, Inc. © 2016 International League Against Epilepsy.

  14. High prevalence of dental fluorosis among adolescents is a growing concern: a school based cross-sectional study from Southern India.

    PubMed

    Verma, Anand; Shetty, Bharatesh K; Guddattu, Vasudeva; Chourasia, Mehul K; Pundir, Prachi

    2017-04-04

    Fluorosis, caused by ingestion of excessive amount of fluoride through food or water, is a major public health problem in India. This study was undertaken to quantify the dental fluorosis burden among school going adolescents and to find factors associated with dental fluorosis in Kolar taluka, Karnataka, India. A total of 1026 high school adolescents (12-17 years) were enrolled from different schools selected by stratified sampling method. Dental examination was done to record Dean's fluorosis index, and socio-demographic, food consumption and oral hygiene data were recorded using a pre-tested structured questionnaire. Fluoride content was measured using Orion apparatus, and Community Fluorosis Index (CFI) was calculated from drinking water samples from various drinking sources. Multivariable analysis with generalized estimating equation (GEE) regression model was used to explore the factors associated with dental fluorosis. Among 1026 enrolled students, 64.3% of adolescents were detected with dental fluorosis; more than 50% had either severe or moderate fluorosis according to the Dean's Fluorosis Index and Community Fluorosis Index (CFI). The majority of affected students were from government schools. The significantly associated factors with dental fluorosis were living in study area for more than 5 years and studying in government school. A strong positive correlation between the amount of fluoride content in drinking water sample collected and CFI was observed (rho = 0.570). Prevalence of dental fluorosis was considerably high, affecting nearly two-thirds of the students, and mainly in government schools and long-term residents of the area. Health education and community awareness for preventing fluorosis, apart from setting-up defluoridation plants or training for home based defluoridation techniques in study villages, should be considered.

  15. Reversible preoperative renal dysfunction does not add to the risk of postoperative acute kidney injury after cardiac valve surgery

    PubMed Central

    Xu, Jia-Rui; Zhuang, Ya-Min; Liu, Lan; Shen, Bo; Wang, Yi-Mei; Luo, Zhe; Teng, Jie; Wang, Chun-Sheng; Ding, Xiao-Qiang

    2017-01-01

    Objective To evaluate the impact of the renal dysfunction (RD) type and change of postoperative cardiac function on the risk of developing acute kidney injury (AKI) in patients who underwent cardiac valve surgery. Method Reversible renal dysfunction (RRD) was defined as preoperative RD in patients who had not been initially diagnosed with chronic kidney disease (CKD). Cardiac function improvement (CFI) was defined as postoperative left ventricular ejection function – preoperative left ventricular ejection function (ΔEF) >0%, and cardiac function not improved (CFNI) as ΔEF ≤0%. Results Of the 4,805 (94%) cardiac valve surgery patients, 301 (6%) were RD cases. The AKI incidence in the RRD group (n=252) was significantly lower than in the CKD group (n=49) (36.5% vs 63.3%, P=0.018). The AKI and renal replacement therapy incidences in the CFI group (n=174) were significantly lower than in the CFNI group (n=127) (33.9% vs 50.4%, P=0.004; 6.3% vs 13.4%, P=0.037). After adjustment for age, gender, and other confounding factors, CKD and CKD + CFNI were identified as independent risk factors for AKI in all patients after cardiac valve surgery. Multivariate logistic regression analysis showed that the risk factors for postoperative AKI in preoperative RD patients were age, gender (male), hypertension, diabetes, chronic heart failure, cardiopulmonary bypass time (every 1 min added), and intraoperative hypotension, while CFI after surgery could reduce the risk. Conclusion For cardiac valve surgery patients, preoperative CKD was an independent risk factor for postoperative AKI, but RRD did not add to the risk. Improved postoperative cardiac function can significantly reduce the risk of postoperative AKI. PMID:29184415

  16. Goal importance within planned behaviour theory as 'the' predictor of study behaviour in college.

    PubMed

    Sideridis, G D; Kaissidis-Rodafinos, A

    2001-12-01

    The theory of planned behaviour has been rarely used for the explanation of student study behaviour and achievement. Although successful, the theory has been criticised for not including important cognitions, so goal importance was added in the present study. Goal importance refers to the weight-importance an individual assigns towards achieving a specific goal (Hollenbeck & Williams, 1987). The purpose of Study 1 was to explain the study behaviour habits of first year college students, using a) Ajzen and Madden's (1986) theory of planned behaviour, and b) planned behaviour with the addition of goal importance. The purpose of Study 2 was to replicate the findings of Study 1. The sample of Study 1 included 149 first year students of an American College located in northern Greece. Study 2 included 85 first year students of the same institution. The students in Study 1 were given a questionnaire four weeks prior to the end of the spring 1998 semester, and those in Study 2 in the autumn of 1998, including all elements of the theory of planned behaviour and goal importance. The data were modelled using Covariance Structural Modelling (CSM) and EQS 5.7b (Bentler, 1998). The planned behaviour model was not well supported in Study 1 providing a Comparative Fit Index (CFI) of.83. However, when goal importance was included in the equation, the resulting structural model produced a CFI of.94. The final structural model of Study 1 was re-tested with the sample of Study 2 and produced a CFI =.95. Findings suggest that goal importance is the causal agent in directing all elements necessary to achieve high levels of study behaviour. Future studies should examine the role of goal importance with other behaviours as well.

  17. Rare genetic variants in Tunisian Jewish patients suffering from age-related macular degeneration.

    PubMed

    Pras, Eran; Kristal, Dana; Shoshany, Nadav; Volodarsky, Dina; Vulih, Inna; Celniker, Gershon; Isakov, Ofer; Shomron, Noam; Pras, Elon

    2015-07-01

    To explore the molecular basis of familial, early onset, age-related macular degeneration (AMD) with diverse phenotypes, using whole exome sequencing (WES). We performed WES on four patients (two sibs from two families) manifesting early-onset AMD and searched for disease-causing genetic variants in previously identified macular degeneration related genes. Validation studies of the variants included bioinformatics tools, segregation analysis of mutations within the families and mutation screening in an AMD cohort of patients. The index patients were in their 50s when diagnosed and displayed a wide variety of clinical AMD presentations: from limited drusen in the posterior pole to multiple basal-laminar drusen extending peripherally. Severe visual impairment due to extensive geographic atrophy and/or choroidal-neovascularisation was common by the age of 75 years. Approximately, 400 000 genomic variants for each DNA sample were included in the downstream bioinformatics analysis, which ended in the discovery of two novel variants; in one family a single bp deletion was identified in the Hemicentin (HMCN1) gene (c.4162delC), whereas in the other, a missense variant (p.V412M) in the Complement Factor-I (CFI) gene was found. Screening for these variants in a cohort of patients with AMD identified another family with the CFI variant. This report uses WES to uncover rare genetic variants in AMD. A null-variant in HMCN1 has been identified in one AMD family, and a missense variant in CFI was discovered in two other families. These variants confirm the genetic complexity and significance of rare genetic variants in the pathogenesis of AMD. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  18. Examining the Latent Structure of the Delis-Kaplan Executive Function System.

    PubMed

    Karr, Justin E; Hofer, Scott M; Iverson, Grant L; Garcia-Barrera, Mauricio A

    2018-05-04

    The current study aimed to determine whether the Delis-Kaplan Executive Function System (D-KEFS) taps into three executive function factors (inhibition, shifting, fluency) and to assess the relationship between these factors and tests of executive-related constructs less often measured in latent variable research: reasoning, abstraction, and problem solving. Participants included 425 adults from the D-KEFS standardization sample (20-49 years old; 50.1% female; 70.1% White). Eight alternative measurement models were compared based on model fit, with test scores assigned a priori to three factors: inhibition (Color-Word Interference, Tower), shifting (Trail Making, Sorting, Design Fluency), and fluency (Verbal/Design Fluency). The Twenty Questions, Word Context, and Proverb Tests were predicted in separate structural models. The three-factor model fit the data well (CFI = 0.938; RMSEA = 0.047), although a two-factor model, with shifting and fluency merged, fit similarly well (CFI = 0.929; RMSEA = 0.048). A bifactor model fit best (CFI = 0.977; RMSEA = 0.032) and explained the most variance in shifting indicators, but rarely converged among 5,000 bootstrapped samples. When the three first-order factors simultaneously predicted the criterion variables, only shifting was uniquely predictive (p < .05; R2 = 0.246-0.408). The bifactor significantly predicted all three criterion variables (p < .001; R2 = 0.141-242). Results supported a three-factor D-KEFS model (i.e., inhibition, shifting, and fluency), although shifting and fluency were highly related (r = 0.696). The bifactor showed superior fit, but converged less often than other models. Shifting best predicted tests of reasoning, abstraction, and problem solving. These findings support the validity of D-KEFS scores for measuring executive-related constructs and provide a framework through which clinicians can interpret D-KEFS results.

  19. A Catalogue of Systems for Student Ratings of Instruction.

    ERIC Educational Resources Information Center

    Abrami, Philip C.; Murphy, Vincent

    This catalogue briefly describes the following 12 systems for student ratings of instruction in higher education: (1) Purdue Cafeteria System (Cafeteria); (2) Course Faculty Instrument (CFI); (3) Arizona Course/Instructor Evaluation Questionnaire (CIEQ); (4) Endeavor Instructional Rating System (Endeavor); (5) University of Washington…

  20. The Relationship Between Life Satisfaction and ADHD Symptoms in Middle School Students: Using a Bifactor Model.

    PubMed

    Ogg, Julia A; Bateman, Lisa; Dedrick, Robert F; Suldo, Shannon M

    2016-05-01

    ADHD is associated with increased academic and social difficulties and comorbid psychopathology which may lead to decreased life satisfaction (LS). The current study utilized a bifactor model of ADHD consisting of a general factor and two specific factors (inattention and hyperactivity-impulsivity) to determine if ADHD symptoms place middle school students (n= 183) at risk for diminished LS and if this relationship differed depending on whether teachers versus students reported ADHD symptoms. Confirmatory factor analyses indicated that the bifactor model provided very good fit to the ADHD symptoms reported by students (comparative fit index [CFI] = .995; root mean square error of approximation [RMSEA] = .028) and teachers (CFI = .997; RMSEA = .043). Results also demonstrated that when students rated ADHD symptoms, the general ADHD factor and inattention were negatively related to LS; however, when teachers rated ADHD symptoms, only inattention was negatively related to LS. Implications and future directions related to these results are discussed. © The Author(s) 2014.

  1. 77 FR 37038 - Clean Air Act Operating Permit Program; Petition for Objection to State Operating Permit for CF&I...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-20

    ... title V of the Clean Air Act (Act) by WildEarth Guardians (Petitioner), to object to CDPHE's December 28.... EPA received a petition from WildEarth Guardians dated March 24, 2011, requesting that EPA object to...

  2. Structural and Discriminant Validity of the Career Factors Inventory

    ERIC Educational Resources Information Center

    Dickinson, Josephine; Tokar, David M.

    2004-01-01

    Using a sample of 350 college students, this study examined the structural and discriminant validity of the Career Factors Inventory (CFI; Chartrand, Robbins, Morrill, & Boggs, 1990), a multidimensional measure of career indecision intended to be scored for two informational indecision components (Need for Career Information and Need for…

  3. Acupuncture Effects on Cardiac Functions Measured by Cardiac Magnetic Resonance Imaging in a Feline Model

    PubMed Central

    Lin, Jen-Hsou; Shih, Chen-Haw; Kaphle, Krishna; Wu, Leang-Shin; Tseng, Weng-Yih; Chiu, Jen-Hwey; Lee, Tzu-chi

    2010-01-01

    The usefulness of acupuncture (AP) as a complementary and/or alternative therapy in animals is well established but more research is needed on its clinical efficacy relative to conventional therapy, and on the underlying mechanisms of the effects of AP. Cardiac magnetic resonance imaging (CMRI), an important tool in monitoring cardiovascular diseases, provides a reliable method to monitor the effects of AP on the cardiovascular system. This controlled experiment monitored the effect electro-acupuncture (EA) at bilateral acupoint Neiguan (PC6) on recovery time after ketamine/xylazine cocktail anesthesia in healthy cats. The CMRI data established the basic feline cardiac function index (CFI), including cardiac output and major vessel velocity. To evaluate the effect of EA on the functions of the autonomic nervous and cardiovascular systems, heart rate, respiration rate, electrocardiogram and pulse rate were also measured. Ketamine/xylazine cocktail anesthesia caused a transient hypertension in the cats; EA inhibited this anesthetic-induced hypertension and shortened the post-anesthesia recovery time. Our data support existing knowledge on the cardiovascular benefits of EA at PC6, and also provide strong evidence for the combination of anesthesia and EA to shorten post-anesthesia recovery time and counter the negative effects of anesthetics on cardiac physiology. PMID:18955311

  4. Impact of Participation in Decision Making on Job Satisfaction: An Organizational Communication Perspective.

    PubMed

    Xia, Ying; Zhang, Li; Zhao, Ning

    2016-09-20

    Participation in organizational decision-making has received considerable attention from scholars. Beyond the perspectives proposed in past studies, we offer a new account, based upon a communication perspective, to explain why and when participation in decision-making can influence job satisfaction. Drawing from social capital theory, we examine whether communication openness mediates the relationship between participation in decision-making and job satisfaction. We also investigate how information adequacy moderates this mediated process. Results from a sample of 184 employees in China showed that the four-factor model was the best fitting solution (CFI = .91, GFI = .90, RMSEA = .09). The analyses indicated that employees' participation in decision-making positively affected their job satisfaction (β = .32, p < .001), and the effect was mediated by communication openness (direct effect became non-significant when communication openness was included: β = .06, n.s.). Results also found that decision-making information adequacy positively moderated the relationship between participation in decision-making and communication openness (β = .13, p < .05). Thus, open communication and the free flow of information within organizations should be encouraged.

  5. Critical Fusion--Technology and Equity in Secondary Education

    ERIC Educational Resources Information Center

    Magolda, Peter

    2006-01-01

    This manuscript reports on the first year of a formative, external program evaluation of the Critical Fusion Initiative (CFI), which involved a higher education institution, a public high school, a corporation, and two nonprofit organizations. The initiative fused technology and education to address the issue of equity by assisting 16 high school…

  6. 75 FR 48726 - Notice of Lodging of Consent Decree Under the Resource Conservation and Recovery Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-11

    ... single production facility in Plant City, Florida that has been in operation at the current approximate 3... settlement, CFI has re-engineered its plant to cease generating hazardous wastewater previously commingled... reduction program; install synthetic protective barriers beneath its production plants; provide $163.5...

  7. Ceramic-Ceramic Composites Meeting in Belgium.

    DTIC Science & Technology

    1987-08-04

    the liquid phase Vidrio , Madrid, Spain) described the use should disappear during the heat treat- of SIC grains as a dispersed phase to ment. The...SiC fiber-reinforced SiO2 glass ma- trix, mullite-zirconia-A120 3-SiC, C-fi- used elastic wave measurements at high ber-reinforced reaction-bonded SiC

  8. 12 CFR 950.3 - Purpose of long-term advances; Proxy test.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... fund new or existing residential housing finance assets, which include, for CFI members, small business loans, small farm loans and small agri-business loans. (b)(1) Prior to approving an application for a....3 Section 950.3 Banks and Banking FEDERAL HOUSING FINANCE BOARD FEDERAL HOME LOAN BANK ASSETS AND...

  9. Relationship between Counseling Students' Childhood Memories and Current Negative Self-Evaluations When Receiving Corrective Feedback

    ERIC Educational Resources Information Center

    Stroud, Daniel; Olguin, David; Marley, Scott

    2016-01-01

    This article entails a study focused on the relationship between counseling students' negative childhood memories of receiving corrective feedback and current negative self-evaluations when receiving similar feedback in counselor education programs. Participants (N = 186) completed the Corrective Feedback Instrument-Revised (CFI-R; Hulse-Killacky…

  10. A Dream Realized

    ERIC Educational Resources Information Center

    Pierpont, Katherine

    2005-01-01

    This article features the Center for Inquiry, a school where the teachers are making their dreams come true. As a school designed wholly by teachers, the Center for Inquiry (CFI) in Indianapolis, Indiana, is teaching kids how to take ownership of learning. Originally designed to be a school within a school for exchange and preservice teachers, the…

  11. Power and sensitivity of alternative fit indices in tests of measurement invariance.

    PubMed

    Meade, Adam W; Johnson, Emily C; Braddy, Phillip W

    2008-05-01

    Confirmatory factor analytic tests of measurement invariance (MI) based on the chi-square statistic are known to be highly sensitive to sample size. For this reason, G. W. Cheung and R. B. Rensvold (2002) recommended using alternative fit indices (AFIs) in MI investigations. In this article, the authors investigated the performance of AFIs with simulated data known to not be invariant. The results indicate that AFIs are much less sensitive to sample size and are more sensitive to a lack of invariance than chi-square-based tests of MI. The authors suggest reporting differences in comparative fit index (CFI) and R. P. McDonald's (1989) noncentrality index (NCI) to evaluate whether MI exists. Although a general value of change in CFI (.002) seemed to perform well in the analyses, condition specific change in McDonald's NCI values exhibited better performance than a single change in McDonald's NCI value. Tables of these values are provided as are recommendations for best practices in MI testing. PsycINFO Database Record (c) 2008 APA, all rights reserved.

  12. Carbon Nanotube Fiber Ionization Mass Spectrometry: A Fundamental Study of a Multi-Walled Carbon Nanotube Functionalized Corona Discharge Pin for Polycyclic Aromatic Hydrocarbons Analysis.

    PubMed

    Nahan, Keaton S; Alvarez, Noe; Shanov, Vesselin; Vonderheide, Anne

    2017-11-01

    Mass spectrometry continues to tackle many complicated tasks, and ongoing research seeks to simplify its instrumentation as well as sampling. The desorption electrospray ionization (DESI) source was the first ambient ionization source to function without extensive gas requirements and chromatography. Electrospray techniques generally have low efficiency for ionization of nonpolar analytes and some researchers have resorted to methods such as direct analysis in real time (DART) or desorption atmospheric pressure chemical ionization (DAPCI) for their analysis. In this work, a carbon nanotube fiber ionization (nanoCFI) source was developed and was found to be capable of solid phase microextraction (SPME) of nonpolar analytes as well as ionization and sampling similar to that of direct probe atmospheric pressure chemical ionization (DP-APCI). Conductivity and adsorption were maintained by utilizing a corona pin functionalized with a multi-walled carbon nanotube (MWCNT) thread. Quantitative work with the nanoCFI source with a designed corona discharge pin insert demonstrated linearity up to 0.97 (R 2 ) of three target PAHs with phenanthrene internal standard. Graphical Abstract ᅟ.

  13. Prevalence of dental fluorosis among primary school children in association with different water fluoride levels in Mysore district, Karnataka.

    PubMed

    Sebastian, Shibu Thomas; Soman, Rino Roopak; Sunitha, S

    2016-01-01

    Fluoride intake at optimal level decreases the incidence of dental caries. However, excessive intake, especially during developmental stages can cause adverse effects such as dental and skeletal fluorosis. To assess the prevalence and severity of dental fluorosis in primary school children born and raised in three villages of Mysore District. The three selected villages have different water fluoride concentrations. Three villages namely, Nerale (water fluoride 2.0 ppm), Belavadi (1.2 ppm) and Naganahally (0.4 ppm) were selected for the study. Then, a total of 405 children, 10-12-year-old (204 [50.4%] males and 201 [49.60%] females) were selected from three schools of the villages. Dean's fluorosis index recommended by World Health Organization was used to evaluate fluorosis among the study population. The overall prevalence of dental fluorosis was found to be 41.73%. An increase in the community fluorosis index (CFI) was higher among those living in high water fluoride area. A significantly positive correlation was found between CFI and water fluoride concentration in drinking water.

  14. RNA polymerase beta-subunit gene (rpoB) sequence analysis for the identification of Bacteroides spp.

    PubMed

    Ko, K S; Kuwahara, T; Haehwa, L; Yoon, Y-J; Kim, B-J; Lee, K-H; Ohnishi, Y; Kook, Y-H

    2007-01-01

    Partial rpoB sequences (317 bp) of 11 species of Bacteroides, two Porphyromonas spp. and two Prevotella spp. were compared to delineate the genetic relationships among Bacteroides and closely related anaerobic species. The high level of inter-species sequence dissimilarities (7.6-20.8%) allowed the various Bacteroides spp. to be distinguished. The position of the Bacteroides distasonis and Bacteriodes merdae cluster in the rpoB tree was different from the position in the 16S rRNA gene tree. Based on rpoB sequence similarity and clustering in the rpoB tree, it was possible to correctly re-identify 80 clinical isolates of Bacteroides. In addition to two subgroups, cfiA-negative (division I) and cfiA-positive (division II), of Bacteroides fragilis isolates, two distinct subgroups were also found among Bacteroides ovatus and Bacteroides thetaiotaomicron isolates. Bacteroides genus-specific rpoB PCR and B. fragilis species-specific rpoB PCR allowed Bacteroides spp. to be differentiated from Porphyromonas and Prevotella spp., and also allowed B. fragilis to be differentiated from other non-fragilisBacteroides spp. included in the present study.

  15. Carbon Nanotube Fiber Ionization Mass Spectrometry: A Fundamental Study of a Multi-Walled Carbon Nanotube Functionalized Corona Discharge Pin for Polycyclic Aromatic Hydrocarbons Analysis

    NASA Astrophysics Data System (ADS)

    Nahan, Keaton S.; Alvarez, Noe; Shanov, Vesselin; Vonderheide, Anne

    2017-09-01

    Mass spectrometry continues to tackle many complicated tasks, and ongoing research seeks to simplify its instrumentation as well as sampling. The desorption electrospray ionization (DESI) source was the first ambient ionization source to function without extensive gas requirements and chromatography. Electrospray techniques generally have low efficiency for ionization of nonpolar analytes and some researchers have resorted to methods such as direct analysis in real time (DART) or desorption atmospheric pressure chemical ionization (DAPCI) for their analysis. In this work, a carbon nanotube fiber ionization (nanoCFI) source was developed and was found to be capable of solid phase microextraction (SPME) of nonpolar analytes as well as ionization and sampling similar to that of direct probe atmospheric pressure chemical ionization (DP-APCI). Conductivity and adsorption were maintained by utilizing a corona pin functionalized with a multi-walled carbon nanotube (MWCNT) thread. Quantitative work with the nanoCFI source with a designed corona discharge pin insert demonstrated linearity up to 0.97 (R2) of three target PAHs with phenanthrene internal standard. [Figure not available: see fulltext.

  16. Leading people positively: cross-cultural validation of the Servant Leadership Survey (SLS).

    PubMed

    Rodríguez-Carvajal, Raquel; de Rivas, Sara; Herrero, Marta; Moreno-Jiménez, Bernardo; van Dierendonck, Dirk

    2014-10-24

    Servant Leadership emphasizes employee's development and growth within a context of moral and social concern. Nowadays, this management change towards workers´ wellbeing is highlighted as an important issue. The aims of this paper are to adapt to Spanish speakers the Servant Leadership Survey (SLS) by van Dierendonck and Nuijten (2011), and to analyze its factorial validity through confirmatory factor analysis and measurement invariance in three countries. A sample of 638 working people from three Spanish-speaking countries (Spain, Argentina and Mexico) participated in the study. In all three countries, confirmatory factor analyses corroborate the eight factor structure (empowerment, accountability, standing back, humility, authenticity, courage, forgiveness and stewardship) with one second order factor (servant leadership) (in all three samples, CFI, IFI > .92, TLI > .91, RMSEA < .70). Also, factor loadings, reliability and convergent validity were acceptable across samples. Furthermore, through measurement invariance analysis, we detected model equivalence in all three countries including structural residual invariance (ΔCFI = .001). Finally, cultural differences in some dimensions were found and discussed, opening the way for future cross-cultural studies.

  17. Hyperspectral imaging flow cytometer

    DOEpatents

    Sinclair, Michael B.; Jones, Howland D. T.

    2017-10-25

    A hyperspectral imaging flow cytometer can acquire high-resolution hyperspectral images of particles, such as biological cells, flowing through a microfluidic system. The hyperspectral imaging flow cytometer can provide detailed spatial maps of multiple emitting species, cell morphology information, and state of health. An optimized system can image about 20 cells per second. The hyperspectral imaging flow cytometer enables many thousands of cells to be characterized in a single session.

  18. An Overview of the Comet Nucleus TOUR Discovery Mission and a Description of Neutral Gas and Ion Measurements Planned

    NASA Technical Reports Server (NTRS)

    Mahaffy, Paul; Veverka, Joe; Niemann, Hasso; Harpold, Dan; Chiu, Mary; Reynolds, Edward; Owen, Toby; Kasprzak, Wayne; Patrick, Ed; Raaen, Eric

    2001-01-01

    The CONTOUR (Comet Nucleus TOUR) Mission led by its Principal Investigator Professor Joseph Veverka of Cornell is presently under development at the Johns Hopkins Applied Physics Laboratory for launch in July of 2002 with a flyby of Comet Encke scheduled for November 3, 2003 at a solar distance of 1.07 au. A robust Whipple dust shield is designed to allow a close nucleus approach distance (less than 150 km). The 2nd nominal CONTOUR target is Comet Schwassmann-Wachmann 3, although the spacecraft can alternately be directed to a new comet if such an interesting target is discovered. CONTOUR contains 4 instruments: an imaging spectrometer (CRISP) developed at APL that will obtain both high resolution nucleus images through 8 filters and IR spectra (800 to 2550 nm) of the nucleus, a narrow field of view forward imager (CFI) to locate the target days before the encounter, a dust composition time of flight mass spectrometer (CIDA) provided by Dr. J. Kissel and von Hoemer & Sulger, GmbH, and a mass spectrometer (NGIMS) provided by Goddard Space Flight Center to measure neutral gas and ambient ions. Laboratory calibration of the NGIMS has now been completed. NGIMS also includes an in-flight calibration system that we plan to exercise before and after each comet encounter. We will provide an overview of the CONTOUR Mission and discuss more specifically the NGIMS measurement goals for this mission.

  19. Review of photoacoustic flow imaging: its current state and its promises

    PubMed Central

    van den Berg, P.J.; Daoudi, K.; Steenbergen, W.

    2015-01-01

    Flow imaging is an important method for quantification in many medical imaging modalities, with applications ranging from estimating wall shear rate to detecting angiogenesis. Modalities like ultrasound and optical coherence tomography both offer flow imaging capabilities, but suffer from low contrast to red blood cells and are sensitive to clutter artefacts. Photoacoustic imaging (PAI) is a relatively new field, with a recent interest in flow imaging. The recent enthusiasm for PA flow imaging is due to its intrinsic contrast to haemoglobin, which offers a new spin on existing methods of flow imaging, and some unique approaches in addition. This review article will delve into the research on photoacoustic flow imaging, explain the principles behind the many techniques and comment on their individual advantages and disadvantages. PMID:26640771

  20. Review of photoacoustic flow imaging: its current state and its promises.

    PubMed

    van den Berg, P J; Daoudi, K; Steenbergen, W

    2015-09-01

    Flow imaging is an important method for quantification in many medical imaging modalities, with applications ranging from estimating wall shear rate to detecting angiogenesis. Modalities like ultrasound and optical coherence tomography both offer flow imaging capabilities, but suffer from low contrast to red blood cells and are sensitive to clutter artefacts. Photoacoustic imaging (PAI) is a relatively new field, with a recent interest in flow imaging. The recent enthusiasm for PA flow imaging is due to its intrinsic contrast to haemoglobin, which offers a new spin on existing methods of flow imaging, and some unique approaches in addition. This review article will delve into the research on photoacoustic flow imaging, explain the principles behind the many techniques and comment on their individual advantages and disadvantages.

  1. Development and Validation of the Body Concealment Scale for Scleroderma.

    PubMed

    Jewett, Lisa R; Malcarne, Vanessa L; Kwakkenbos, Linda; Harcourt, Diana; Rumsey, Nichola; Körner, Annett; Steele, Russell J; Hudson, Marie; Baron, Murray; Haythornthwaite, Jennifer A; Heinberg, Leslie; Wigley, Fredrick M; Thombs, Brett D

    2016-08-01

    Body concealment is a component of social avoidance among people with visible differences from disfiguring conditions, including systemic sclerosis (SSc). The study objective was to develop a measure of body concealment related to avoidance behaviors in SSc. Initial items for the Body Concealment Scale for Scleroderma (BCSS) were selected using item analysis in a development sample of 93 American SSc patients. The factor structure of the BCSS was evaluated in 742 Canadian patients with single-factor, 2-factor, and bifactor confirmatory factor analysis models. Convergent and divergent validity were assessed by comparing the BCSS total score with the Brief-Satisfaction with Appearance Scale (Brief-SWAP) and measures of depressive symptoms and pain. A 2-factor model (Comparative Fit Index [CFI] 0.99, Tucker-Lewis Index [TLI] 0.98, Root Mean Square Error of Approximation [RMSEA] 0.08) fit substantially better than a 1-factor model (CFI 0.95, TLI 0.94, RMSEA 0.15) for the 9-item BCSS, but the Concealment with Clothing and Concealment of Hands factors were highly correlated (α = 0.79). The bifactor model (CFI 0.99, TLI 0.99, RMSEA 0.08) also fit well. In the bifactor model, the omega coefficient was high for the general factor (ω = 0.80), but low for the Concealment with Clothing (ω = 0.01) and Concealment of Hands (ω = 0.33) factors. The BCSS total score correlated more strongly with the Brief-SWAP Social Discomfort (r = 0.59) and Dissatisfaction with Appearance (r = 0.53) subscales than with measures of depressive symptoms and pain. The BCSS sum score is a valid indicator of body concealment in SSc that extends the concepts of body concealment and avoidance beyond the realms of body shape and weight to concerns of individuals with visible differences from SSc. © 2016, American College of Rheumatology.

  2. Confirmatory factor analysis of the Infant Feeding Styles Questionnaire in Latino families.

    PubMed

    Wood, Charles T; Perreira, Krista M; Perrin, Eliana M; Yin, H Shonna; Rothman, Russell L; Sanders, Lee M; Delamater, Alan M; Bentley, Margaret E; Bronaugh, Andrea B; Thompson, Amanda L

    2016-05-01

    Parent feeding practices affect risk of obesity in children. Latino children are at higher risk of obesity than the general population, yet valid measure of feeding practices, one of which is the Infant Feeding Styles Questionnaire (IFSQ), have not been formally validated in Spanish. To validate the IFSQ among Latino families, we conducted confirmatory factor analysis of pressuring, restrictive, and responsive feeding constructs from the IFSQ. The IFSQ was administered at the 12-month visit in the Greenlight study, a multi-center cluster randomized trial to prevent obesity. Parents were included if they were of Latino origin (n = 303) and completed an English or Spanish language modified IFSQ (without the indulgence construct). Scores from nine sub-constructs of the IFSQ were compared between English and Spanish language versions. We tested reliability with Cronbach's alpha coefficients and performed confirmatory factor analysis to examine factor loadings and goodness of fit characteristics, modifying constructs to achieve best fit. Of 303 parents completing the IFSQ, 84% were born outside the US, and 74% completed the IFSQ in Spanish. Reliability coefficients ranged from 0.28 to 0.61 for the laissez-faire sub-constructs and from 0.58 to 0.83 for the pressuring, restrictive, and responsive sub-constructs. Results for all coefficients were similar between participants responding to an English and Spanish version of the IFSQ. Goodness of fit indices ranged from CFI 0.82-1 and RMSEA 0.00-0.31, and the model performed best in pressuring-soothing (CFI 1.0, RMSEA 0.00) and restrictive-amount (CFI 0.98, RMSEA 0.1) sub-constructs. In a sample of Latino families, pressuring, restrictive, and responsive constructs performed well. The modified IFSQ in both English and Spanish-speaking Latino families may be used to assess parenting behaviors related to early obesity risk in this at-risk population. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Factor structure of a conceptual model of oral health tested among 65-year olds in Norway and Sweden.

    PubMed

    Astrøm, Anne Nordrehaug; Ekbäck, Gunnar; Ordell, Sven

    2010-04-01

    No studies have tested oral health-related quality of life models in dentate older adults across different populations. To test the factor structure of oral health outcomes within Gilbert's conceptual model among 65-year olds in Sweden and Norway. It was hypothesized that responses to 14 observed indicators could be explained by three correlated factors, symptom status, functional limitations and oral disadvantages, that each observed oral health indicator would associate more strongly with the factor it is supposed to measure than with competing factors and that the proposed 3-factor structure would possess satisfactory cross-national stability with 65-year olds in Norway and Sweden. In 2007, 6078 Swedish- and 4062 Norwegian adults borne in 1942 completed mailed questionnaires including oral symptoms, functional limitations and the eight item Oral Impacts on Daily Performances inventory. Model generation analysis was restricted to the Norwegian study group and the model achieved was tested without modifications in Swedish 65-year olds. A modified 3-factor solution with cross-loadings, improved the fit to the data compared with a 2-factor- and the initially proposed 3-factor model among the Norwegian [comparative fit index (CFI) = 0.97] and Swedish (CFI = 0.98) participants. All factor loadings for the modified 3-factor model were in the expected direction and were statistically significant at CR > 1. Multiple group confirmatory factor analyses, with Norwegian and Swedish data simultaneously revealed acceptable fit for the unconstrained model (CFI = 0.97), whereas unconstrained and constrained models were statistically significant different in nested model comparison. Within construct validity of Gilbert's model was supported with Norwegian and Swedish 65-year olds, indicating that the 14-item questionnaire reflected three constructs; symptom status, functional limitation and oral disadvantage. Measurement invariance was confirmed at the level of factor structure, suggesting that the 3-factor model is comparable to some extent across 65-year olds in Norway and Sweden.

  4. The ACTIVE conceptual framework as a structural equation model

    PubMed Central

    Gross, Alden L.; Payne, Brennan R.; Casanova, Ramon; Davoudzadeh, Pega; Dzierzewski, Joseph M.; Farias, Sarah; Giovannetti, Tania; Ip, Edward H.; Marsiske, Michael; Rebok, George W.; Schaie, K. Warner; Thomas, Kelsey; Willis, Sherry; Jones, Richard N.

    2018-01-01

    Background/Study Context Conceptual frameworks are analytic models at a high level of abstraction. Their operationalization can inform randomized trial design and sample size considerations. Methods The Advanced Cognitive Training for Independent and Vital Elderly (ACTIVE) conceptual framework was empirically tested using structural equation modeling (N=2,802). ACTIVE was guided by a conceptual framework for cognitive training in which proximal cognitive abilities (memory, inductive reasoning, speed of processing) mediate treatment-related improvement in primary outcomes (everyday problem-solving, difficulty with activities of daily living, everyday speed, driving difficulty), which in turn lead to improved secondary outcomes (health-related quality of life, health service utilization, mobility). Measurement models for each proximal, primary, and secondary outcome were developed and tested using baseline data. Each construct was then combined in one model to evaluate fit (RMSEA, CFI, normalized residuals of each indicator). To expand the conceptual model and potentially inform future trials, evidence of modification of structural model parameters was evaluated by age, years of education, sex, race, and self-rated health status. Results Preconceived measurement models for memory, reasoning, speed of processing, everyday problem-solving, instrumental activities of daily living (IADL) difficulty, everyday speed, driving difficulty, and health-related quality of life each fit well to the data (all RMSEA < .05; all CFI > .95). Fit of the full model was excellent (RMSEA = .038; CFI = .924). In contrast with previous findings from ACTIVE regarding who benefits from training, interaction testing revealed associations between proximal abilities and primary outcomes are stronger on average by nonwhite race, worse health, older age, and less education (p < .005). Conclusions Empirical data confirm the hypothesized ACTIVE conceptual model. Findings suggest that the types of people who show intervention effects on cognitive performance potentially may be different from those with the greatest chance of transfer to real-world activities. PMID:29303475

  5. Development of a brief tool for monitoring aberrant behaviours among patients receiving long-term opioid therapy: The Opioid-Related Behaviours In Treatment (ORBIT) scale.

    PubMed

    Larance, Briony; Bruno, Raimondo; Lintzeris, Nicholas; Degenhardt, Louisa; Black, Emma; Brown, Amanda; Nielsen, Suzanne; Dunlop, Adrian; Holland, Rohan; Cohen, Milton; Mattick, Richard P

    2016-02-01

    Early identification of problems is essential in minimising the unintended consequences of opioid therapy. This study aimed to develop a brief scale that identifies and quantifies recent aberrant behaviour among diverse patient populations receiving long-term opioid treatment. 40 scale items were generated via literature review and expert panel (N=19) and tested in surveys of: (i) N=41 key experts, and (ii) N=426 patients prescribed opioids >3 months (222 pain patients and 204 opioid substitution therapy (OST) patients). We employed item and scale psychometrics (exploratory factor analyses, confirmatory factor analyses and item-response theory statistics) to refine items to a brief scale. Following removal of problematic items (poor retest-reliability or wording, semantic redundancy, differential item functioning, collinearity or rarity) iterative factor analytic procedures identified a 10-item unifactorial scale with good model fit in the total sample (N=426; CFI=0.981, TLI=0.975, RMSEA=0.057), and among pain (CFI=0.969, TLI=0.960, RMSEA=0.062) and OST subgroups (CFI=0.989, TFI=0.986, RMSEA=0.051). The 10 items provided good discrimination between groups, demonstrated acceptable test-retest reliability (ICC 0.80, 95% CI 0.60-0.89; Cronbach's alpha=0.89), were moderately correlated with related constructs, including opioid dependence (SDS), depression and stress (DASS subscales) and Social Relationships and Environment domains of the WHO-QoL, and had strong face validity among advising clinicians. The Opioid-Related Behaviours In Treatment (ORBIT) scale is brief, reliable and validated for use in diverse patient groups receiving opioids. The ORBIT has potential applications as a checklist to prompt clinical discussions and as a tool to quantify aberrant behaviour and assess change over time. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  6. Confirmatory Factor Analysis of the Infant Feeding Styles Questionnaire in Latino Families

    PubMed Central

    Wood, Charles T.; Perreira, Krista M.; Perrin, Eliana M.; Yin, H. Shonna; Rothman, Russell L.; Sanders, Lee M.; Delamater, Alan M.; Bentley, Margaret E.; Bronaugh, Andrea B.; Thompson, Amanda L.

    2016-01-01

    Background Parent feeding practices affect risk of obesity in children. Latino children are at higher risk of obesity than the general population, yet valid measure of feeding practices, one of which is the Infant Feeding Styles Questionnaire (IFSQ), have not been formally validated in Spanish. Objective To validate the IFSQ among Latino families, we conducted confirmatory factor analysis of pressuring, restrictive, and responsive feeding constructs from the IFSQ. Design/Methods The IFSQ was administered at the 12-month visit in the Greenlight study, a multi-center cluster randomized trial to prevent obesity. Parents were included if they were of Latino origin (n=303) and completed an English or Spanish language modified IFSQ (without the indulgence construct). Scores from nine sub-constructs of the IFSQ were compared between English and Spanish language versions. We tested reliability with Cronbach’s alpha coefficients and performed confirmatory factor analysis to examine factor loadings and goodness of fit characteristics, modifying constructs to achieve best fit. Results Of 303 parents completing the IFSQ, 84% were born outside the US, and 74% completed the IFSQ in Spanish. Reliability coefficients ranged from 0.28–0.61 for the laissez-faire sub-constructs and from 0.58–0.83 for the pressuring, restrictive, and responsive sub-constructs. Results for all coefficients were similar between participants responding to an English and Spanish version of the IFSQ. Goodness of fit indices ranged from CFI 0.82–1 and RMSEA 0.00–0.31, and the model performed best in pressuring-soothing (CFI 1.0, RMSEA 0.00) and restrictive-amount (CFI 0.98, RMSEA 0.1) sub-constructs. Conclusions In a sample of Latino families, pressuring, restrictive, and responsive constructs performed well. The modified IFSQ in both English and Spanish-speaking Latino families may be used to assess parenting behaviors related to early obesity risk in this at-risk population. PMID:26876910

  7. High throughput analysis of samples in flowing liquid

    DOEpatents

    Ambrose, W. Patrick; Grace, W. Kevin; Goodwin, Peter M.; Jett, James H.; Orden, Alan Van; Keller, Richard A.

    2001-01-01

    Apparatus and method enable imaging multiple fluorescent sample particles in a single flow channel. A flow channel defines a flow direction for samples in a flow stream and has a viewing plane perpendicular to the flow direction. A laser beam is formed as a ribbon having a width effective to cover the viewing plane. Imaging optics are arranged to view the viewing plane to form an image of the fluorescent sample particles in the flow stream, and a camera records the image formed by the imaging optics.

  8. Pulsed photoacoustic flow imaging with a handheld system

    NASA Astrophysics Data System (ADS)

    van den Berg, Pim J.; Daoudi, Khalid; Steenbergen, Wiendelt

    2016-02-01

    Flow imaging is an important technique in a range of disease areas, but estimating low flow speeds, especially near the walls of blood vessels, remains challenging. Pulsed photoacoustic flow imaging can be an alternative since there is little signal contamination from background tissue with photoacoustic imaging. We propose flow imaging using a clinical photoacoustic system that is both handheld and portable. The system integrates a linear array with 7.5 MHz central frequency in combination with a high-repetition-rate diode laser to allow high-speed photoacoustic imaging-ideal for this application. This work shows the flow imaging performance of the system in vitro using microparticles. Both two-dimensional (2-D) flow images and quantitative flow velocities from 12 to 75 mm/s were obtained. In a transparent bulk medium, flow estimation showed standard errors of ˜7% the estimated speed; in the presence of tissue-realistic optical scattering, the error increased to 40% due to limited signal-to-noise ratio. In the future, photoacoustic flow imaging can potentially be performed in vivo using fluorophore-filled vesicles or with an improved setup on whole blood.

  9. Flow-gated radial phase-contrast imaging in the presence of weak flow.

    PubMed

    Peng, Hsu-Hsia; Huang, Teng-Yi; Wang, Fu-Nien; Chung, Hsiao-Wen

    2013-01-01

    To implement a flow-gating method to acquire phase-contrast (PC) images of carotid arteries without use of an electrocardiography (ECG) signal to synchronize the acquisition of imaging data with pulsatile arterial flow. The flow-gating method was realized through radial scanning and sophisticated post-processing methods including downsampling, complex difference, and correlation analysis to improve the evaluation of flow-gating times in radial phase-contrast scans. Quantitatively comparable results (R = 0.92-0.96, n = 9) of flow-related parameters, including mean velocity, mean flow rate, and flow volume, with conventional ECG-gated imaging demonstrated that the proposed method is highly feasible. The radial flow-gating PC imaging method is applicable in carotid arteries. The proposed flow-gating method can potentially avoid the setting up of ECG-related equipment for brain imaging. This technique has potential use in patients with arrhythmia or weak ECG signals.

  10. Pseudo-CFI for industrial forest industries

    Treesearch

    Francis A. Roesch

    2000-01-01

    Corporate inventory systems have historically had a greater spatial and temporal intensity than is common in the public sector. For many corporations, these inventory systems might be described as dynamic in that current estimates rely on a small amount of recent data and a large amount of information resulting from the imputation of older data that have been...

  11. Pseudo-CFI for industrial forest inventories

    Treesearch

    Francis A. Roesch

    2000-01-01

    Corporate inventory systems have historically had a greater spatial and temporal intensity than is common in the public sector. For many corporations, these inventory systems might be described as dynamic in that current estimates rely on a small amount of recent data and a large amount of information resulting from the imputation of older data that have been subjected...

  12. Stain Associated with Nails in Trees on Permanent Plots

    Treesearch

    Charles B. Briscoe; Benton H. Box

    1959-01-01

    In studies involving the measurement and subsequent remeasurement of trees, such as CFI plots or siliviculture research plots, the trees are commonly identified by metal tags fastened to the trees by means of nails. In 1957 a study was begun to determine whether this practice would lead to dregrade or scalable defect in the trees.

  13. Use of FVS for a forest-wide inventory on the Spokane Indian Reservation

    Treesearch

    Ted Hensold

    2008-01-01

    The Forest Vegetation Simulator (FVS) was used with Continuous Forest Inventory (CFI) data on the Spokane Indian Reservation to provide predicted yields over a 100-year period for 994 1/5 acre plots. The plots were grouped into five strata based on habitat type groupings, projected separately, and the stratum results were combined after processing. Results from the...

  14. A stand density management diagram for sawtimber-sized mixed upland central hardwoods

    Treesearch

    J.A., Jr. Kershaw; B.C. Fischer

    1991-01-01

    Data from 190 CFI plots located in southern and west-central Indiana are used to develop a stand density diagram for sawtimber-sized mixed upland hardwoods in the Central States. The stand density diagram utilizes the concepts of self-thinning to establish a maximum size-density curve, and the stocking standards of Gingrich (1967) to formulate imtermediate stocking...

  15. Volume growth of pine and hardwood in uneven-aged loblolly pine-upland hardwood mixtures

    Treesearch

    Robert M. Farrar; Paul A. Murphy; Daniel J. Leduc

    1989-01-01

    Results are reported from an exploratory investigation of stand-level periodic volume growth of uneven-aged mixed loblolly pine (Pinus taeda L.)-upland hardwood stands on good sites in southeastern Arkansas. A restricted set of replicated observations was extracted from an extensive CFI database involving varying pine-hardwood mixtures to form an array of plots with...

  16. 46 CFR Table I to Part 150 - Alphabetical List of Cargoes

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... (C17+) alkanoic acid 34 CUS CFT Corn syrup 43 CSY Cottonseed oil, fatty acid 34 CFY Creosote 21 2 CCT... tar 33 COR OCT Coal tar distillate 33 CDL Coal tar, high temperature 33 CHH Coal tar pitch 33 CTP... MTM Formaldehyde solution 19 2 FMS Formamide 10 FAM Formic acid 4 2 FMA Fructose solution 43 Fumaric...

  17. 46 CFR Table I to Part 150 - Alphabetical List of Cargoes

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... (C17+) alkanoic acid 34 CUS CFT Corn syrup 43 CSY Cottonseed oil, fatty acid 34 CFY Creosote 21 2 CCT... tar 33 COR OCT Coal tar distillate 33 CDL Coal tar, high temperature 33 CHH Coal tar pitch 33 CTP... MTM Formaldehyde solution 19 2 FMS Formamide 10 FAM Formic acid 4 2 FMA Fructose solution 43 Fumaric...

  18. 46 CFR Table I to Part 150 - Alphabetical List of Cargoes

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... (C17+) alkanoic acid 34 CUS CFT Corn syrup 43 CSY Cottonseed oil, fatty acid 34 CFY Creosote 21 2 CCT... tar 33 COR OCT Coal tar distillate 33 CDL Coal tar, high temperature 33 CHH Coal tar pitch 33 CTP... MTM Formaldehyde solution 19 2 FMS Formamide 10 FAM Formic acid 4 2 FMA Fructose solution 43 Fumaric...

  19. 46 CFR Table I to Part 150 - Alphabetical List of Cargoes

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... (C17+) alkanoic acid 34 CUS CFT Corn syrup 43 CSY Cottonseed oil, fatty acid 34 CFY Creosote 21 2 CCT... tar 33 COR OCT Coal tar distillate 33 CDL Coal tar, high temperature 33 CHH Coal tar pitch 33 CTP... MTM Formaldehyde solution 19 2 FMS Formamide 10 FAM Formic acid 4 2 FMA Fructose solution 43 Fumaric...

  20. 46 CFR Table I to Part 150 - Alphabetical List of Cargoes

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... (C17+) alkanoic acid 34 CUS CFT Corn syrup 43 CSY Cottonseed oil, fatty acid 34 CFY Creosote 21 2 CCT... tar 33 COR OCT Coal tar distillate 33 CDL Coal tar, high temperature 33 CHH Coal tar pitch 33 CTP... MTM Formaldehyde solution 19 2 FMS Formamide 10 FAM Formic acid 4 2 FMA Fructose solution 43 Fumaric...

  1. Validity of the Brunel Mood Scale for use With Malaysian Athletes.

    PubMed

    Lan, Mohamad Faizal; Lane, Andrew M; Roy, Jolly; Hanin, Nik Azma

    2012-01-01

    The aim of the present study was to investigate the factorial validity of the Brunel Mood Scale for use with Malaysian athletes. Athletes (N = 1485 athletes) competing at the Malaysian Games completed the Brunel of Mood Scale (BRUMS). Confirmatory Factor Analysis (CFA) results indicated a Confirmatory Fit Index (CFI) of .90 and Root Mean Squared Error of Approximation (RMSEA) was 0.05. The CFI was below the 0.95 criterion for acceptability and the RMSEA value was within the limits for acceptability suggested by Hu and Bentler, 1999. We suggest that results provide some support for validity of the BRUMS for use with Malaysian athletes. Given the large sample size used in the present study, descriptive statistics could be used as normative data for Malaysian athletes. Key pointsFindings from the present study lend support to the validity of the BRUMS for use with Malaysian athletes.Given the size of the sample used in the present study, we suggest descriptive data be used as the normative data for researchers using the scale with Malaysian athletes.It is suggested that future research investigate the effects of cultural differences on emotional states experienced by athletes before, during and post-competition.

  2. Validity of the Brunel Mood Scale for use With Malaysian Athletes

    PubMed Central

    Lan, Mohamad Faizal; Lane, Andrew M.; Roy, Jolly; Hanin, Nik Azma

    2012-01-01

    The aim of the present study was to investigate the factorial validity of the Brunel Mood Scale for use with Malaysian athletes. Athletes (N = 1485 athletes) competing at the Malaysian Games completed the Brunel of Mood Scale (BRUMS). Confirmatory Factor Analysis (CFA) results indicated a Confirmatory Fit Index (CFI) of .90 and Root Mean Squared Error of Approximation (RMSEA) was 0.05. The CFI was below the 0.95 criterion for acceptability and the RMSEA value was within the limits for acceptability suggested by Hu and Bentler, 1999. We suggest that results provide some support for validity of the BRUMS for use with Malaysian athletes. Given the large sample size used in the present study, descriptive statistics could be used as normative data for Malaysian athletes. Key points Findings from the present study lend support to the validity of the BRUMS for use with Malaysian athletes. Given the size of the sample used in the present study, we suggest descriptive data be used as the normative data for researchers using the scale with Malaysian athletes. It is suggested that future research investigate the effects of cultural differences on emotional states experienced by athletes before, during and post-competition. PMID:24149128

  3. Structure of four executive functioning tests in healthy older adults.

    PubMed

    de Frias, Cindy M; Dixon, Roger A; Strauss, Esther

    2006-03-01

    The authors examined the factor structure of 4 indicators of executive functioning derived from 2 new (i.e., Hayling and Brixton) and 2 traditional (i.e., Stroop and Color Trails) tests. Data were from a cross-sectional sample of 55- to 85-year-old healthy adults (N=427) from the Victoria Longitudinal Study. Confirmatory factor analysis (LISREL 8.52) tested both a 2-factor model of Inhibition (Hayling, Stroop) and Shifting (Brixton, Color Trails) and a single-factor model. The 2-factor model did not fit the data because the covariance matrix of the factors was not positive definite. The single-factor model fit the data well, chi(2)(2, N=427)=0.32, p=.85, root-mean-square error of approximation (RMSEA)=.00, comparative fit index (CFI)=1.00, goodness-of-fit index (GFI)=1.00. Moreover, the single-factor structure of executive functioning was invariant (configural and metric) across gender, and invariant (configural with limited metric) across age. Structural relations showed that poorer executive functioning performance was related to older age and lower fluid intelligence, chi(2)(11, N=418)=23.04, p=.02, RMSEA=.05, CFI=.97, GFI=.98.

  4. Validation of the Davidson Trauma Scale in its original and a new shorter version in people exposed to the F-27 earthquake in Chile

    PubMed Central

    Leiva-Bianchi, Marcelo C.; Araneda, Andrea C.

    2013-01-01

    Background On February 27, 2010 (F-27), an earthquake and tsunami occurred having a significant impact on the mental health of the Chilean population, leading to an increase in cases of post-traumatic stress disorder (PTSD). Objectives Within this context, validated for the first time in Chile was the Davidson Trauma Scale (DTS) using three samples (each one consisting of 200 participants), two of them random from the Chilean population. Results Reliability analyses (i.e., α=0.933), concurrent validity (63% of the items are significantly correlated with the criteria variable “degree of damage to home”) and construct validity (i.e., CMIN = 3.754, RMSEA = 0.118, NFI = 0.808, CFI = 0.850 and PNFI = 0.689) indicate validity between regular and good for DTS. However, a new short version of the scale (DTS-SF) created using the items with heavier factor weights, presented better fits (CMIN = 2.170, RMSEA = 0.077, NFI = 0.935, CFI = 0.963, PNFI = 0.697). Discussion Finally, the usefulness of DTS and DTS-SF is discussed, the latter being briefer, valid and having better psychometric characteristics. PMID:23983920

  5. Measuring affect at work based on the valence and arousal circumplex model.

    PubMed

    Madrid, Hector P; Patterson, Malcolm G

    2014-01-01

    Affective states have become a central topic of interest in research on organizational behavior. Recently, scholars have been paying more attention to the proposals of the Circumplex Model (Russell, 1980) in order to gain a finer grained understanding of job-related affect. However, the limited availability of well-validated measures to test this model in work settings, particularly in non English-speaking populations, is still a major drawback. Using three samples of English-speaking and Spanish-speaking workers, this article offers the cross-validation of the Multi-Affect Indicator (Warr, 2007) between the original English version and its corresponding translation into Spanish. Multi-group Structural Equation Modeling supported the instrument's structure and its invariance between the two languages (English: χ2 = 65.56, df = 48, p = .05; RMSEA = .06; CFI = .97; Spanish: χ2 = 68.68, df = 48, p = .03; RMSEA = .05; CFI = .97). Furthermore, Circular Stochastic Modeling supported the theoretically proposed circumplex representation (χ2 = 139.85, df = 51, p < .01; χ2/df = 2.74, RMSEA = .06). Thus, this study offers an instrument that provides a more accurate approximation to affect at work, both in English and in another of the major language communities in the world, the Spanish-speaking population.

  6. Psychometric Properties of the Brief Version of the Social Skills Inventory for Adolescents.

    PubMed

    Romera Leme, Vanessa Barbosa; Valentini, Felipe; Campos, Josiane Rosa; Del Prette, Almir; Del Prette, Zilda A P

    2017-07-31

    The present study aimed to evaluate the evidence of internal structure and scores reliability of the Social Skills Inventory for adolescents - brief version (IHSA-Del-Prette). The following analyses were performed: (1) Exploratory Factor Analysis - EFA; (2) Confirmatory Factor Analysis - CFA; (3) Reliability; (4) Multigroup Analysis (invariance). The participants were 2,291 students of the Middle and High Schools, both sexes aged 12 to 17 years old divided into two sample groups: 1,172 participants in sample group 1 (collected 2006-2007) and 1,119 in sample group 2 (collected 2011-2012). The results of the EFA (group 1) support the four subscales structure (Self-control, Affective Approach, Empathy and Assertiveness) for 16 items (loadings > .30). The structure was confirmed by the CFA performed on the second group (CFI = .96, TLI = .95, RMSEA = .05, 90% CI [.04, .05], loadings > .50); and showed scalar invariance (samples 1 and 2) due to group and age, as well as partial scalar invariance due to gender (ΔCFI < .01; ΔNCI < .02). It was concluded the brief version of IHSA-Del-Prette presents psychometric properties for use in the Brazilian context.

  7. Social ecological determinants of youth violence among ethnically diverse Asian and Pacific Islander students.

    PubMed

    Goebert, Deborah; Chang, Janice Y; Chung-Do, Jane; Else, 'Iwalani R N; Hamagami, Fumiaki; Helm, Susana; Kinkade, Katie; Sugimoto-Matsuda, Jeanelle J

    2012-01-01

    This study assesses the relative fit of risk/protective and social ecological models of youth violence among predominantly Asian and Pacific Islander students. Data from a 2007 survey of two multi-ethnic high schools in Hawai'i were used. The survey assessed interpersonal youth violence, suicidality and risk and protective factors. Two models of youth violence (risk/protective and social ecological) were tested using structural equation modeling. We found good fits for the risk/protective model (χ(2) = 369.42, df = 77, P < .0001; CFI = .580; RMSEA = .066) and the ecological model (χ(2) = 1763.65, df = 292, P < .0001; CFI = .636; RMSEA = .076). The risk/protective model showed the importance of coping skills. However, the ecological model allowed examination of the interconnectivity among factors. Peer exposure to violence had no direct influence on individuals and peer influence was fully mediated by school climate. Furthermore, family factors directly contributed to peer exposure, community, and individual risk/protection. These findings have significant implications for intervention and prevention efforts and for the promotion of positive, competent, and healthy youth development. While few family and school-based programs have been developed and evaluated for adolescents, they have the greatest potential for success.

  8. 4D phase contrast flow imaging for in-stent flow visualization and assessment of stent patency in peripheral vascular stents--a phantom study.

    PubMed

    Bunck, Alexander C; Jüttner, Alena; Kröger, Jan Robert; Burg, Matthias C; Kugel, Harald; Niederstadt, Thomas; Tiemann, Klaus; Schnackenburg, Bernhard; Crelier, Gerard R; Heindel, Walter; Maintz, David

    2012-09-01

    4D phase contrast flow imaging is increasingly used to study the hemodynamics in various vascular territories and pathologies. The aim of this study was to assess the feasibility and validity of MRI based 4D phase contrast flow imaging for the evaluation of in-stent blood flow in 17 commonly used peripheral stents. 17 different peripheral stents were implanted into a MR compatible flow phantom. In-stent visibility, maximal velocity and flow visualization were assessed and estimates of in-stent patency obtained from 4D phase contrast flow data sets were compared to a conventional 3D contrast-enhanced magnetic resonance angiography (CE-MRA) as well as 2D PC flow measurements. In all but 3 of the tested stents time-resolved 3D particle traces could be visualized inside the stent lumen. Quality of 4D flow visualization and CE-MRA images depended on stent type and stent orientation relative to the magnetic field. Compared to the visible lumen area determined by 3D CE-MRA, estimates of lumen patency derived from 4D flow measurements were significantly higher and less dependent on stent type. A higher number of stents could be assessed for in-stent patency by 4D phase contrast flow imaging (n=14) than by 2D phase contrast flow imaging (n=10). 4D phase contrast flow imaging in peripheral vascular stents is feasible and appears advantageous over conventional 3D contrast-enhanced MR angiography and 2D phase contrast flow imaging. It allows for in-stent flow visualization and flow quantification with varying quality depending on stent type. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  9. True color blood flow imaging using a high-speed laser photography system

    NASA Astrophysics Data System (ADS)

    Liu, Chien-Sheng; Lin, Cheng-Hsien; Sun, Yung-Nien; Ho, Chung-Liang; Hsu, Chung-Chi

    2012-10-01

    Physiological changes in the retinal vasculature are commonly indicative of such disorders as diabetic retinopathy, glaucoma, and age-related macular degeneration. Thus, various methods have been developed for noninvasive clinical evaluation of ocular hemodynamics. However, to the best of our knowledge, current ophthalmic instruments do not provide a true color blood flow imaging capability. Accordingly, we propose a new method for the true color imaging of blood flow using a high-speed pulsed laser photography system. In the proposed approach, monochromatic images of the blood flow are acquired using a system of three cameras and three color lasers (red, green, and blue). A high-quality true color image of the blood flow is obtained by assembling the monochromatic images by means of image realignment and color calibration processes. The effectiveness of the proposed approach is demonstrated by imaging the flow of mouse blood within a microfluidic channel device. The experimental results confirm the proposed system provides a high-quality true color blood flow imaging capability, and therefore has potential for noninvasive clinical evaluation of ocular hemodynamics.

  10. Aortic Valve Stenosis Increases Helical Flow and Flow Complexity: A Study of Intra-Operative Cardiac Vector Flow Imaging.

    PubMed

    Hansen, Kristoffer Lindskov; Møller-Sørensen, Hasse; Kjaergaard, Jesper; Jensen, Maiken Brit; Jensen, Jørgen Arendt; Nielsen, Michael Bachmann

    2017-08-01

    Aortic valve stenosis alters blood flow in the ascending aorta. Using intra-operative vector flow imaging on the ascending aorta, secondary helical flow during peak systole and diastole, as well as flow complexity of primary flow during systole, were investigated in patients with normal, stenotic and replaced aortic valves. Peak systolic helical flow, diastolic helical flow and flow complexity during systole differed between the groups (p < 0.0001), and correlated to peak systolic velocity (R = 0.94, 0.87 and 0.88, respectively). The study indicates that aortic valve stenosis increases helical flow and flow complexity, which are measurable with vector flow imaging. For assessment of aortic stenosis and optimization of valve surgery, vector flow imaging may be useful. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  11. Local scattering property scales flow speed estimation in laser speckle contrast imaging

    NASA Astrophysics Data System (ADS)

    Miao, Peng; Chao, Zhen; Feng, Shihan; Yu, Hang; Ji, Yuanyuan; Li, Nan; Thakor, Nitish V.

    2015-07-01

    Laser speckle contrast imaging (LSCI) has been widely used in in vivo blood flow imaging. However, the effect of local scattering property (scattering coefficient µ s ) on blood flow speed estimation has not been well investigated. In this study, such an effect was quantified and involved in relation between speckle autocorrelation time τ c and flow speed v based on simulation flow experiments. For in vivo blood flow imaging, an improved estimation strategy was developed to eliminate the estimation bias due to the inhomogeneous distribution of the scattering property. Compared to traditional LSCI, a new estimation method significantly suppressed the imaging noise and improves the imaging contrast of vasculatures. Furthermore, the new method successfully captured the blood flow changes and vascular constriction patterns in rats’ cerebral cortex from normothermia to mild and moderate hypothermia.

  12. High carrier concentration ZnO nanowire arrays for binder-free conductive support of supercapacitors electrodes by Al doping.

    PubMed

    Zheng, Xin; Sun, Yihui; Yan, Xiaoqin; Sun, Xu; Zhang, Guangjie; Zhang, Qian; Jiang, Yaru; Gao, Wenchao; Zhang, Yue

    2016-12-15

    Doping semiconductor nanowires (NWs) for altering their electrical and optical properties is a critical strategy for tailoring the performance of nanodevices. Here, we prepared in situ Al-doped ZnO nanowire arrays by using continuous flow injection (CFI) hydrothermal method to promote the conductivity. This reasonable method offers highly stable precursor concentration for doping that effectively avoid the appearance of the low conductivity ZnO nanosheets. Benefit from this, three orders of magnitude rise of the carrier concentration from 10 16 cm -3 to 10 19 cm -3 can be achieved compared with the common hydrothermal (CH) mothed in Mott-Schottky measurement. Possible effect of Al-doping was discussed by first-principle theory. On this basis, Al-doped ZnO nanowire arrays was developed as a binder-free conductive support for supercapacitor electrodes and high capacitance was triggered. It is owing to the dramatically decreased transfer resistance induced by the growing free-moving electrons and holes. Our results have a profound significance not merely in the controlled synthesis of other doping nanomaterials by co-precipitation method but also in the application of binder-free energy materials or other materials. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Feasibility of 4D flow MR imaging of the brain with either Cartesian y-z radial sampling or k-t SENSE: comparison with 4D Flow MR imaging using SENSE.

    PubMed

    Sekine, Tetsuro; Amano, Yasuo; Takagi, Ryo; Matsumura, Yoshio; Murai, Yasuo; Kumita, Shinichiro

    2014-01-01

    A drawback of time-resolved 3-dimensional phase contrast magnetic resonance (4D Flow MR) imaging is its lengthy scan time for clinical application in the brain. We assessed the feasibility for flow measurement and visualization of 4D Flow MR imaging using Cartesian y-z radial sampling and that using k-t sensitivity encoding (k-t SENSE) by comparison with the standard scan using SENSE. Sixteen volunteers underwent 3 types of 4D Flow MR imaging of the brain using a 3.0-tesla scanner. As the standard scan, 4D Flow MR imaging with SENSE was performed first and then followed by 2 types of acceleration scan-with Cartesian y-z radial sampling and with k-t SENSE. We measured peak systolic velocity (PSV) and blood flow volume (BFV) in 9 arteries, and the percentage of particles arriving from the emitter plane at the target plane in 3 arteries, visually graded image quality in 9 arteries, and compared these quantitative and visual data between the standard scan and each acceleration scan. 4D Flow MR imaging examinations were completed in all but one volunteer, who did not undergo the last examination because of headache. Each acceleration scan reduced scan time by 50% compared with the standard scan. The k-t SENSE imaging underestimated PSV and BFV (P < 0.05). There were significant correlations for PSV and BFV between the standard scan and each acceleration scan (P < 0.01). The percentage of particles reaching the target plane did not differ between the standard scan and each acceleration scan. For visual assessment, y-z radial sampling deteriorated the image quality of the 3 arteries. Cartesian y-z radial sampling is feasible for measuring flow, and k-t SENSE offers sufficient flow visualization; both allow acquisition of 4D Flow MR imaging with shorter scan time.

  14. Children's Emerging Digital Literacies: Investigating Home Computing in Low- and Middle-Income Families. CCT Reports.

    ERIC Educational Resources Information Center

    Ba, Harouna; Tally, Bill; Tsikalas, Kallen

    The EDC (Educational Development Center) Center for Children and Technology (CCT) and Computers for Youth (CFY) completed a 1-year comparative study of children's use of computers in low- and middle-income homes. The study explores the digital divide as a literacy issue, rather than merely a technical one. Digital literacy is defined as a set of…

  15. Effect of the environment on participation in spinal cord injuries/disorders: The mediating impact of resilience, grief, and self-efficacy.

    PubMed

    Locatelli, Sara M; Etingen, Bella; Miskevics, Scott; LaVela, Sherri L

    2017-08-01

    The objective of the study was to test the hypothesis that the influence of environmental barriers on participation will be fully mediated by psychosocial factors (resilience, grief or loss, and self-efficacy) among individuals with spinal cord injuries and disorders. This was a cross-sectional mailed survey with a national sample of veterans with spinal cord injuries and disorders (n = 565), which included measures of demographics, perceived environmental barriers, participation, resilience, grief or loss, and self-efficacy. Data were analyzed using a latent variable path analysis; the model fit was assessed using χ2, normed χ2, root mean square error of approximation (RMSEA; <0.07), Comparative Fit Index (CFI; ≥0.95), and Tucker-Lewis Index (TLI; ≥0.95). Participants were mostly male (93.9%), Caucasian or White (74.2%), and, on average, 62.4 years of age (SD = 10.48). Almost 62% had paraplegia, and 38.3% had a motor or sensory complete injury. The hypothesized model showed excellent fit, χ2(42) = 153.40, normed χ2 = 3.65, RMSEA = 0.07, CFI = 0.96, TLI = 0.95. To assess for full mediation, a direct path was added from environment to participation. This model showed nearly identical fit, χ2(41) = 153.39, normed χ2 = 3.74, RMSEA = 0.07, CFI = 0.96, TLI = 0.95; the path from environment to participation was not significant, unstandardized coefficient = -0.04, p = .92. Examination of indirect effects of the hypothesized model demonstrated that environment significantly influences participation through psychosocial factors, unstandardized coefficient = -4.85, p < .001. Together these results support full mediation. In conclusion the present study expands upon past research by suggesting that perceived environmental barriers play a role in internal factors, such as resilience and self-efficacy, which in turn influence participation. Interventions to improve environmental barriers may be warranted, but attention must also be paid to resilience, grief or loss, and self-efficacy to increase participation. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  16. General Oral Health Assessment Index: A new evaluation proposal.

    PubMed

    Campos, Juliana A D B; Zucoloto, Miriane L; Bonafé, Fernanda S S; Maroco, João

    2017-09-01

    To validity the General Oral Health Assessment Index (GOHAI) among adults who sought dental care and to present a new proposal for calculating scores on self-perception of oral health. There is no study that presents a GOHAI scores using weight of the items. The one-factor model, the three-factor model (physical function, psychosocial/psychological function and pain/discomfort) and the second-order hierarchical model (SOHM) were evaluated from confirmatory factor analysis (λ, χ 2 /df, CFI,GFI and RMSEA). The reliability (CR,α) was estimated. Concurrent validity was assessed using the Oral Health Impact Profile (OHIP-14). The invariance of the models was estimated in independent samples. The calculation of an overall score using the factor scores was proposed to obtain the overall weighted scores. These overall weighted scores were compared to the scores estimated as the simple arithmetic mean (overall unweighted scores) using a repeated measures analysis of variance. A total of 1000 individuals participated (74.1% female; age: 40.7 (SD=14.3) years). Three items of the GOHAI were excluded (λ<0.40). The one-factor model (λ=0.40-0.77; χ 2 /df=6.291; CFI=0.947; GFI=0.960; RMSEA=0.073) and the three-factor model (λ=0.40-0.78; χ 2 /df=8.321; CFI=0.932; GFI=0.954; RMSEA=0.086) each presented an adequate fit. Reliability was adequate (one-factor: CR=0.83/α=0.83; three-factor: CR=0.53-0.76/α=0.53-0.73), with the exception of the pain/discomfort factor. The GOHAI was invariant in independent samples, and the concurrent validity was adequate. The overall unweighted scores overestimated self-perceptions of oral health when compared with the weighted scores. Both the one-factor and three-factor models of the GOHAI were found to be valid, reliable and invariant for the sample after the exclusion of three items. The use of overall weighted scores is recommended for calculating the score of self-perception of oral health. © 2017 John Wiley & Sons A/S and The Gerodontology Association. Published by John Wiley & Sons Ltd.

  17. [Evaporating Droplet and Imaging Slip Flows

    NASA Technical Reports Server (NTRS)

    Larson, R. G.

    2002-01-01

    In this report, we summarize work on Evaporating Droplet and Imaging Slip Flows. The work was primarily performed by post-doc Hue Hu, and partially by grad students Lei Li and Danish Chopra. The work includes studies on droplet evaporation and its effects on temperature and velocity fields in an evaporating droplet, new 3-D microscopic particle image velocimetry and direct visualization on wall slip in a surfactant solution. With the exception of the slip measurements, these projects were those proposed in the grant application. Instead of slip flow, the original grant proposed imaging electro-osmotic flows. However, shortly after the grant was issued, the PI became aware of work on electro-osmotic flows by the group of Saville in Princeton that was similar to that proposed, and we therefore elected to carry out work on imaging slip flows rather than electro-osmotic flows.

  18. Temporal and spatial evolution characteristics of gas-liquid two-phase flow pattern based on image texture spectrum descriptor

    NASA Astrophysics Data System (ADS)

    Zhou, Xi-Guo; Jin, Ning-De; Wang, Zhen-Ya; Zhang, Wen-Yin

    2009-11-01

    The dynamic image information of typical gas-liquid two-phase flow patterns in vertical upward pipe is captured by a highspeed dynamic camera. The texture spectrum descriptor is used to describe the texture characteristics of the processed images whose content is represented in the form of texture spectrum histogram, and four time-varying characteristic parameter indexes which represent image texture structure of different flow patterns are extracted. The study results show that the amplitude fluctuation of texture characteristic parameter indexes of bubble flow is lowest and shows very random complex dynamic behavior; the amplitude fluctuation of slug flow is higher and shows intermittent motion behavior between gas slug and liquid slug, and the amplitude fluctuation of churn flow is the highest and shows better periodicity; the amplitude fluctuation of bubble-slug flow is from low to high and oscillating frequence is higher than that of slug flow, and includes the features of both slug flow and bubble flow; the slug-churn flow loses the periodicity of slug flow and churn flow, and the amplitude fluctuation is high. The results indicate that the image texture characteristic parameter indexes of different flow pattern can reflect the flow characteristics of gas-liquid two-phase flow, which provides a new approach to understand the temporal and spatial evolution of flow pattern dynamics.

  19. Measurements of atomic splittings in atomic hydrogen and the proton charge radius

    NASA Astrophysics Data System (ADS)

    Hessels, E. A.

    2016-09-01

    The proton charge radius can be determined from precise measurements of atomic hydrogen spectroscopy. A review of the relevant measurements will be given, including an update on our measurement of the n=2 Lamb shift. The values obtained from hydrogen will be compared to those obtained from muonic hydrogen and from electron-proton elastic scattering measurements. This work is funded by NSERC, CRC and CFI.

  20. Rapid Prototyping of Application Specific Signal Processors (RASSP)

    DTIC Science & Technology

    1992-10-01

    as well as government, research and and COMPASS , and how the improved plan academic institutions. CFI believes that effective might fit in with the... Compass ). libraries for COTS parts Tools and standards would be strongly based on - Ease of Use VHDL in its latest form(s). Block 2 would take * Open...EDIF Comrcial Rel:wased * Logic Inc. capture for Proprietary boards graphical language Logic Compass Schematic Proprietary EDIF; Commercial Released

  1. Parallels in Computer-Aided Design Framework and Software Development Environment Efforts.

    DTIC Science & Technology

    1992-05-01

    de - sign kits, and tool and design management frameworks. Also, books about software engineer- ing environments [Long 91] and electronic design...tool integration [Zarrella 90], and agreement upon a universal de - sign automation framework, such as the CAD Framework Initiative (CFI) [Malasky 91...ments: identification, control, status accounting, and audit and review. The paper by Dart ex- tracts 15 CM concepts from existing SDEs and tools

  2. Rapid Prototyping of Application Specific Signal Processors (RASSP) program - Study Phase

    DTIC Science & Technology

    1992-10-12

    in the quantitative evaluaion of desip ltenatlves. To make sysmms such as IDAS mor effective for...steps, and should invest in the standardization of data models that meet these needs. PDES and CFI are likely to offer the most payoff for such an...provides a bigger picture of the ATR roadmap. It attempts to lay out the projected progress of the ATR technologies and applications, both in the

  3. Stress and Resilience in Functional Somatic Syndromes – A Structural Equation Modeling Approach

    PubMed Central

    Fischer, Susanne; Lemmer, Gunnar; Gollwitzer, Mario; Nater, Urs M.

    2014-01-01

    Background Stress has been suggested to play a role in the development and perpetuation of functional somatic syndromes. The mechanisms of how this might occur are not clear. Purpose We propose a multi-dimensional stress model which posits that childhood trauma increases adult stress reactivity (i.e., an individual's tendency to respond strongly to stressors) and reduces resilience (e.g., the belief in one's competence). This in turn facilitates the manifestation of functional somatic syndromes via chronic stress. We tested this model cross-sectionally and prospectively. Methods Young adults participated in a web survey at two time points. Structural equation modeling was used to test our model. The final sample consisted of 3′054 participants, and 429 of these participated in the follow-up survey. Results Our proposed model fit the data in the cross-sectional (χ2(21)  = 48.808, p<.001, CFI  = .995, TLI  = .992, RMSEA  = .021, 90% CI [.013.029]) and prospective analyses (χ2(21)  = 32.675, p<.05, CFI  = .982, TLI  = .969, RMSEA  = .036, 90% CI [.001.059]). Discussion Our findings have several clinical implications, suggesting a role for stress management training in the prevention and treatment of functional somatic syndromes. PMID:25396736

  4. Psychophysics of reading. XVII. Low-vision performance with four types of electronically magnified text.

    PubMed

    Harland, S; Legge, G E; Luebker, A

    1998-03-01

    Most people with low vision need magnification to read. Page navigation is the process of moving a magnifier during reading. Modern electronic technology can provide many alternatives for navigating through text. This study compared reading speeds for four methods of displaying text. The four methods varied in their page-navigation demands. The closed-circuit television (CCTV) and MOUSE methods involved manual navigation. The DRIFT method (horizontally drifting text) involved no manual navigation, but did involve both smooth-pursuit and saccadic eye movements. The rapid serial visual presentation (RSVP) method involved no manual navigation, and relatively few eye movements. There were 7 normal subjects and 12 low-vision subjects (7 with central-field loss, CFL group, and 5 with central fields intact, CFI group). The subjects read 70-word passages at speeds that yielded good comprehension. Taking the CCTV reading speed as a benchmark, neither the normal nor low-vision subjects had significantly different speeds with the MOUSE method. As expected from the reduced navigational demands, normal subjects read faster with the DRIFT method (85% faster) and the RSVP method (169%). The CFI group read significantly faster with DRIFT (43%) and RSVP (38%). The CFL group showed no significant differences in reading speed for the four methods.

  5. Validation of the Italian version of the Movement Disorder Society--Unified Parkinson's Disease Rating Scale.

    PubMed

    Antonini, Angelo; Abbruzzese, Giovanni; Ferini-Strambi, Luigi; Tilley, Barbara; Huang, Jing; Stebbins, Glenn T; Goetz, Christopher G; Barone, Paolo; Bandettini di Poggio, Monica; Fabbrini, Giovanni; Di Stasio, Flavio; Tinazzi, Michele; Bovi, Tommaso; Ramat, Silvia; Meoni, Sara; Pezzoli, Gianni; Canesi, Margherita; Martinelli, Paolo; Maria Scaglione, Cesa Lorella; Rossi, Aroldo; Tambasco, Nicola; Santangelo, Gabriella; Picillo, Marina; Morgante, Letterio; Morgante, Francesca; Quatrale, Rocco; Sensi, MariaChiara; Pilleri, Manuela; Biundo, Roberta; Nordera, Giampietro; Caria, Antonella; Pacchetti, Claudio; Zangaglia, Roberta; Lopiano, Leonardo; Zibetti, Maurizio; Zappia, Mario; Nicoletti, Alessandra; Quattrone, Aldo; Salsone, Maria; Cossu, Gianni; Murgia, Daniela; Albanese, Alberto; Del Sorbo, Francesca

    2013-05-01

    The Movement Disorder Society-sponsored revision of the Unified Parkinson's Disease Rating Scale (MDS-UPDRS) has been available in English since 2008. As part of this process, the MDS-UPDRS organizing team developed guidelines for development of official non-English translations. We present here the formal process for completing officially approved non-English versions of the MDS-UPDRS and specifically focus on the first of these versions in Italian. The MDS-UPDRS was translated into Italian and tested in 377 native-Italian speaking PD patients. Confirmatory and exploratory factor analyses determined whether the factor structure for the English-language MDS-UPDRS could be confirmed in data collected using the Italian translation. To be designated an 'Official MDS translation,' the Comparative Fit Index (CFI) had to be ≥0.90 relative to the English-language version. For all four parts of the Italian MDS-UPDRS, the CFI, in comparison with the English-language data, was ≥0.94. Exploratory factor analyses revealed some differences between the two datasets, however these differences were considered to be within an acceptable range. The Italian version of the MDS-UPDRS reaches the criterion to be designated as an Official Translation and is now available for use. This protocol will serve as outline for further validation of this in multiple languages.

  6. Family climate and expressed emotion in the course of alcoholism.

    PubMed

    Fichter, M M; Glynn, S M; Weyerer, S; Liberman, R P; Frick, U

    1997-06-01

    Family-based predictors of relapse were examined in 100 alcoholics who participated in a 12-week treatment program with 6-month and 18-month followups. "Expressed Emotion" (EE), or attitudes of relatives toward the alcoholic as measured by the Camberwell Family Interview, scales measuring rejection of the alcoholic by relatives, and self-reports of partner interaction were evaluated as possible predictors of abstinence. During therapy, partnership interactions showed a transient deterioration with increased temporary friction. Based on conservative criteria, the abstinence rate was 40% at 6-month followup and 30% at 18-month followup. An association with the relapse at followup could be obtained for the Patient Rejection Scale (PRS) and, using empirically derived classification rules, for the main three variables of the Camberwell Family Interview (CFI) conducted on admission: "Critical Comments," "Emotional Overinvolvement," and "Warmth." A low number of Critical Comments and a high score in Warmth were associated with a lower risk of relapse; however, contrary to expectations, Emotional Overinvolvement of the significant other was associated with more abstinence. In addition, the number of Critical Comments made by relatives about the alcoholic, a major component of high EE as measured by the CFI, had a statistically significant impact on the "survival function" of abstinence, and thus contributed to the prediction of the course of alcoholism in the expected direction.

  7. Alexithymia, Assertiveness and Psychosocial Functioning in HIV: Implications for Medication Adherence and Disease Severity.

    PubMed

    McIntosh, Roger C; Ironson, Gail; Antoni, Michael; Fletcher, Mary Ann; Schneiderman, Neil

    2016-02-01

    Psychosocial function and adherence to antiretroviral regimen are key factors in human immunodeficiency virus (HIV) disease management. Alexithymia (AL) is a trait deficit in the ability to identify and describe feelings, emotions and bodily sensations. A structural equation model was used to test whether high levels of AL indirectly relate to greater non-adherent behavior and HIV disease severity via psychosocial dysfunction. Blood draws for HIV-1 viral load and CD4 T-lymphocyte, along with psychosocial surveys were collected from 439 HIV positive adults aged 18-73 years. The structural model supports significant paths from: (1) AL to non-active patient involvement, psychological distress, and lower social support, (2) psychological distress and non-active involvement to non-adherent behavior, and (3) non-adherence to greater HIV disease severity (CFI = .97, RMSEA = .04, SRMR = .05). A second model confirmed the intermediary effect of greater patient assertiveness on the path from AL to social support and non-active patient involvement (CFI = .94, RMSEA = .04, SRMR = .05). Altogether, AL is indirectly linked with HIV disease management through it's association with poor psychosocial function, however greater patient assertiveness buffers the negative impact of AL on relationship quality with healthcare providers and members of one's social support network.

  8. A Novel Gradient Vector Flow Snake Model Based on Convex Function for Infrared Image Segmentation

    PubMed Central

    Zhang, Rui; Zhu, Shiping; Zhou, Qin

    2016-01-01

    Infrared image segmentation is a challenging topic because infrared images are characterized by high noise, low contrast, and weak edges. Active contour models, especially gradient vector flow, have several advantages in terms of infrared image segmentation. However, the GVF (Gradient Vector Flow) model also has some drawbacks including a dilemma between noise smoothing and weak edge protection, which decrease the effect of infrared image segmentation significantly. In order to solve this problem, we propose a novel generalized gradient vector flow snakes model combining GGVF (Generic Gradient Vector Flow) and NBGVF (Normally Biased Gradient Vector Flow) models. We also adopt a new type of coefficients setting in the form of convex function to improve the ability of protecting weak edges while smoothing noises. Experimental results and comparisons against other methods indicate that our proposed snakes model owns better ability in terms of infrared image segmentation than other snakes models. PMID:27775660

  9. Schlieren technique in soap film flows

    NASA Astrophysics Data System (ADS)

    Auliel, M. I.; Hebrero, F. Castro; Sosa, R.; Artana, G.

    2017-05-01

    We propose the use of the Schlieren technique as a tool to analyse the flows in soap film tunnels. The technique enables to visualize perturbations of the film produced by the interposition of an object in the flow. The variations of intensity of the image are produced as a consequence of the deviations of the light beam traversing the deformed surfaces of the film. The quality of the Schlieren image is compared to images produced by the conventional interferometric technique. The analysis of Schlieren images of a cylinder wake flow indicates that this technique enables an easy visualization of vortex centers. Post-processing of series of two successive images of a grid turbulent flow with a dense motion estimator is used to derive the velocity fields. The results obtained with this self-seeded flow show good agreement with the statistical properties of the 2D turbulent flows reported on the literature.

  10. Normal flow signal of the pterygoid plexus on 3T MRA in patients without DAVF of the cavernous sinus.

    PubMed

    Watanabe, K; Kakeda, S; Watanabe, R; Ohnari, N; Korogi, Y

    2013-01-01

    Cavernous sinuses and draining dural sinuses or veins are often visualized on 3D TOF MRA images in patients with dural arteriovenous fistulas involving the CS. Flow signals may be seen in the jugular vein and dural sinuses at the skull base on MRA images in healthy participants, however, because of reverse flow. Our purpose was to investigate the prevalence of flow signals in the pterygoid plexus and CS on 3T MRA images in a cohort of participants without DAVFs. Two radiologists evaluated the flow signals of the PP and CS on 3T MRA images obtained from 406 consecutive participants by using a 5-point scale. In addition, the findings on 3T MRA images were compared with those on digital subtraction angiography images in an additional 171 participants who underwent both examinations. The radiologists identified 110 participants (27.1%; 108 left, 10 right, 8 bilateral) with evidence of flow signals in the PP alone (n = 67) or in both the PP and CS (n = 43). Flow signals were significantly more common in the left PP than in the right PP. In 171 patients who underwent both MRA and DSA, the MRA images showed flow signals in the PP with or without CS in 60 patients; no DAVFs were identified on DSA in any of these patients. Flow signals are frequently seen in the left PP on 3T MRA images in healthy participants. This finding may be the result of flow reversal and should not be considered to indicate occult DAVF.

  11. Ultrafast Ultrasound Imaging of Ocular Anatomy and Blood Flow

    PubMed Central

    Urs, Raksha; Ketterling, Jeffrey A.; Silverman, Ronald H.

    2016-01-01

    Purpose Ophthalmic ultrasound imaging is currently performed with mechanically scanned single-element probes. These probes have limited capabilities overall and lack the ability to image blood flow. Linear-array systems are able to detect blood flow, but these systems exceed ophthalmic acoustic intensity safety guidelines. Our aim was to implement and evaluate a new linear-array–based technology, compound coherent plane-wave ultrasound, which offers ultrafast imaging and depiction of blood flow at safe acoustic intensity levels. Methods We compared acoustic intensity generated by a 128-element, 18-MHz linear array operated in conventionally focused and plane-wave modes and characterized signal-to-noise ratio (SNR) and lateral resolution. We developed plane-wave B-mode, real-time color-flow, and high-resolution depiction of slow flow in postprocessed data collected continuously at a rate of 20,000 frames/s. We acquired in vivo images of the posterior pole of the eye by compounding plane-wave images acquired over ±10° and produced images depicting orbital and choroidal blood flow. Results With the array operated conventionally, Doppler modes exceeded Food and Drug Administration safety guidelines, but plane-wave modalities were well within guidelines. Plane-wave data allowed generation of high-quality compound B-mode images, with SNR increasing with the number of compounded frames. Real-time color-flow Doppler readily visualized orbital blood flow. Postprocessing of continuously acquired data blocks of 1.6-second duration allowed high-resolution depiction of orbital and choroidal flow over the cardiac cycle. Conclusions Newly developed high-frequency linear arrays in combination with plane-wave techniques present opportunities for the evaluation of ocular anatomy and blood flow, as well as visualization and analysis of other transient phenomena such as vessel wall motion over the cardiac cycle and saccade-induced vitreous motion. PMID:27428169

  12. Variational optical flow estimation for images with spectral and photometric sensor diversity

    NASA Astrophysics Data System (ADS)

    Bengtsson, Tomas; McKelvey, Tomas; Lindström, Konstantin

    2015-03-01

    Motion estimation of objects in image sequences is an essential computer vision task. To this end, optical flow methods compute pixel-level motion, with the purpose of providing low-level input to higher-level algorithms and applications. Robust flow estimation is crucial for the success of applications, which in turn depends on the quality of the captured image data. This work explores the use of sensor diversity in the image data within a framework for variational optical flow. In particular, a custom image sensor setup intended for vehicle applications is tested. Experimental results demonstrate the improved flow estimation performance when IR sensitivity or flash illumination is added to the system.

  13. Development of a diffraction imaging flow cytometer

    PubMed Central

    Jacobs, Kenneth M.; Lu, Jun Q.

    2013-01-01

    Diffraction images record angle-resolved distribution of scattered light from a particle excited by coherent light and can correlate highly with the 3D morphology of a particle. We present a jet-in-fluid design of flow chamber for acquisition of clear diffraction images in a laminar flow. Diffraction images of polystyrene spheres of different diameters were acquired and found to correlate highly with the calculated ones based on the Mie theory. Fast Fourier transform analysis indicated that the measured images can be used to extract sphere diameter values. These results demonstrate the significant potentials of high-throughput diffraction imaging flow cytometry for extracting 3D morphological features of cells. PMID:19794790

  14. Imaging Electron Motion in a Few Layer MoS2 Device

    NASA Astrophysics Data System (ADS)

    Bhandari, S.; Wang, K.; Watanabe, K.; Taniguchi, T.; Kim, P.; Westervelt, R. M.

    2017-06-01

    Ultrathin sheets of MoS2 are a newly discovered 2D semiconductor that holds great promise for nanoelectronics. Understanding the pattern of current flow will be crucial for developing devices. In this talk, we present images of current flow in MoS2 obtained with a Scanned Probe Microscope (SPM) cooled to 4 K. We previously used this technique to image electron trajectories in GaAs/AlGaAs heterostructures and graphene. The charged SPM tip is held just above the sample surface, creating an image charge inside the device that scatters electrons. By measuring the change in resistance ΔR while the tip is raster scanned above the sample, an image of electron flow is obtained. We present images of electron flow in an MoS2 device patterned into a hall bar geometry. A three-layer MoS2 sheet is encased by two hBN layers, top and bottom, and patterned into a hall-bar with multilayer graphene contacts. An SPM image shows the current flow pattern from the wide contact at the end of the device for a Hall density n = 1.3×1012 cm-2. The SPM tip tends to block flow, increasing the resistance R. The pattern of flow was also imaged for a narrow side contact on the sample. At density n = 5.4×1011 cm-2; the pattern seen in the SPM image is similar to the wide contact. The ability to image electron flow promises to be very useful for the development of ultrathin devices from new 2D materials.

  15. Imaging flow cytometry for phytoplankton analysis.

    PubMed

    Dashkova, Veronika; Malashenkov, Dmitry; Poulton, Nicole; Vorobjev, Ivan; Barteneva, Natasha S

    2017-01-01

    This review highlights the concepts and instrumentation of imaging flow cytometry technology and in particular its use for phytoplankton analysis. Imaging flow cytometry, a hybrid technology combining speed and statistical capabilities of flow cytometry with imaging features of microscopy, is rapidly advancing as a cell imaging platform that overcomes many of the limitations of current techniques and contributed significantly to the advancement of phytoplankton analysis in recent years. This review presents the various instrumentation relevant to the field and currently used for assessment of complex phytoplankton communities' composition and abundance, size structure determination, biovolume estimation, detection of harmful algal bloom species, evaluation of viability and metabolic activity and other applications. Also we present our data on viability and metabolic assessment of Aphanizomenon sp. cyanobacteria using Imagestream X Mark II imaging cytometer. Herein, we highlight the immense potential of imaging flow cytometry for microalgal research, but also discuss limitations and future developments. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. 3D real-time visualization of blood flow in cerebral aneurysms by light field particle image velocimetry

    NASA Astrophysics Data System (ADS)

    Carlsohn, Matthias F.; Kemmling, André; Petersen, Arne; Wietzke, Lennart

    2016-04-01

    Cerebral aneurysms require endovascular treatment to eliminate potentially lethal hemorrhagic rupture by hemostasis of blood flow within the aneurysm. Devices (e.g. coils and flow diverters) promote homeostasis, however, measurement of blood flow within an aneurysm or cerebral vessel before and after device placement on a microscopic level has not been possible so far. This would allow better individualized treatment planning and improve manufacture design of devices. For experimental analysis, direct measurement of real-time microscopic cerebrovascular flow in micro-structures may be an alternative to computed flow simulations. An application of microscopic aneurysm flow measurement on a regular basis to empirically assess a high number of different anatomic shapes and the corresponding effect of different devices would require a fast and reliable method at low cost with high throughout assessment. Transparent three dimensional 3D models of brain vessels and aneurysms may be used for microscopic flow measurements by particle image velocimetry (PIV), however, up to now the size of structures has set the limits for conventional 3D-imaging camera set-ups. On line flow assessment requires additional computational power to cope with the processing large amounts of data generated by sequences of multi-view stereo images, e.g. generated by a light field camera capturing the 3D information by plenoptic imaging of complex flow processes. Recently, a fast and low cost workflow for producing patient specific three dimensional models of cerebral arteries has been established by stereo-lithographic (SLA) 3D printing. These 3D arterial models are transparent an exhibit a replication precision within a submillimeter range required for accurate flow measurements under physiological conditions. We therefore test the feasibility of microscopic flow measurements by PIV analysis using a plenoptic camera system capturing light field image sequences. Averaging across a sequence of single double or triple shots of flashed images enables reconstruction of the real-time corpuscular flow through the vessel system before and after device placement. This approach could enable 3D-insight of microscopic flow within blood vessels and aneurysms at submillimeter resolution. We present an approach that allows real-time assessment of 3D particle flow by high-speed light field image analysis including a solution that addresses high computational load by image processing. The imaging set-up accomplishes fast and reliable PIV analysis in transparent 3D models of brain aneurysms at low cost. High throughput microscopic flow assessment of different shapes of brain aneurysms may therefore be possibly required for patient specific device designs.

  17. The Copernicus Sentinel 4 mission: a geostationary imaging UVN spectrometer for air quality monitoring

    NASA Astrophysics Data System (ADS)

    Bazalgette Courrèges-Lacoste, G.; Sallusti, M.; Bulsa, G.; Bagnasco, G.; Veihelmann, Ben; Riedl, S.; Smith, D. J.; Maurer, R.

    2017-09-01

    Sentinel-4 is an imaging UVN (UV-VIS-NIR) spectrometer, developed by Airbus Defence and Space under ESA contract in the frame of the joint EU/ESA COPERNICUS program. The mission objective is the operational monitoring of trace gas concentrations for atmospheric chemistry and climate applications - hence the motto of Sentinel-4 "Knowing what we breathe". Sentinel-4 will provide accurate measurements of key atmospheric constituents such as ozone, nitrogen dioxide, sulfur dioxide, methane, and aerosol properties over Europe and adjacent regions from a geostationary orbit (see Fig. 1). In the family of already flown UVN spectrometers (SCIAMACHY, OMI, GOME and GOME 2) and of those spectrometers currently under development (Sentinel-5p and Sentinel-5), Sentinel-4 is unique in being the first geostationary UVN mission. Furthermore, thanks to its 60-minutes repeat cycle measurements and high spatial resolution (8x8 km2), Sentinel-4 will increase the frequency of cloud-free observations, which is necessary to assess troposphere variability. Two identical Sentinel-4 instruments (PFM and FM-2) will be embarked, as Customer Furnished Item (CFI), fully verified, qualified and calibrated respectively onto two EUMETSAT satellites: Meteosat Third Generation-Sounder 1 and 2 (MTG-S1 and MTG-S2), whose Flight Acceptance Reviews are presently planned respectively in Q4 2021 and Q1 2030. This paper gives an overview of the Sentinel-4 system1 architecture, its design and development status, current performances and the key technological challenges.

  18. Predictors of orthorexic behaviours in patients with eating disorders: a preliminary study.

    PubMed

    Brytek-Matera, Anna; Rogoza, Radosław; Gramaglia, Carla; Zeppegno, Patrizia

    2015-10-15

    The construct of orthorexia in eating disorders (EDs) has received very little attention despite clinical observations of a possible overlap between the two. The aim of this study was: 1) to assess orthorexic behaviours, eating disorder pathology and attitudinal body image in ED patients; 2) to identify possible predictors of orthorexia nervosa among ED patients. Fifty-two women diagnosed with EDs were recruited. Patients' assessment included the following: the ORTO-15 test (Polish version) for orthorexic behaviours; the Eating Attitude Test-26 (EAT-26) to identify ED symptoms; the Multidimensional Body-Self Relations Questionnaire (Polish version) to assess body image. A latent class analysis was performed and differences between identified classes were assessed. The main differences concerned weight, ED pathology and orthorexic behaviours within the same group of ED patients. In order to examine predictors of orthorexia nervosa, we investigated a structural equation model, which excellently fitted to the data (χ(2)(17) = 23.05; p = .148; CFI = .962; RMSEA = .08; p = .25; SRMR = .05). In ED patients, orthorexic behaviour was negatively predicted by eating pathology, weight concern, health orientation and appearance orientation. The assessment of the orthorexia construct in EDs may add to the paucity of studies about this issue and may help to clarify the relationship between the two. Differences and similarities seem to exist between these disorders, and may benefit from specific treatment approaches. Moreover, these preliminary findings open tracks for future research in the field of the psychology of eating.

  19. Optimal Filter Estimation for Lucas-Kanade Optical Flow

    PubMed Central

    Sharmin, Nusrat; Brad, Remus

    2012-01-01

    Optical flow algorithms offer a way to estimate motion from a sequence of images. The computation of optical flow plays a key-role in several computer vision applications, including motion detection and segmentation, frame interpolation, three-dimensional scene reconstruction, robot navigation and video compression. In the case of gradient based optical flow implementation, the pre-filtering step plays a vital role, not only for accurate computation of optical flow, but also for the improvement of performance. Generally, in optical flow computation, filtering is used at the initial level on original input images and afterwards, the images are resized. In this paper, we propose an image filtering approach as a pre-processing step for the Lucas-Kanade pyramidal optical flow algorithm. Based on a study of different types of filtering methods and applied on the Iterative Refined Lucas-Kanade, we have concluded on the best filtering practice. As the Gaussian smoothing filter was selected, an empirical approach for the Gaussian variance estimation was introduced. Tested on the Middlebury image sequences, a correlation between the image intensity value and the standard deviation value of the Gaussian function was established. Finally, we have found that our selection method offers a better performance for the Lucas-Kanade optical flow algorithm.

  20. Imaging the 3D flow around swimming Chlamydomonas reinhardtii using digital inline holographic microscopy

    NASA Astrophysics Data System (ADS)

    Welch, Kyle; Kumar, Santosh; Hong, Jiarong; Cheng, Xiang

    2017-11-01

    Understanding the 3D flow induced by microswimmers is paramount to revealing how they interact with each other and their environment. While many studies have measured 2D projections of flow fields around single microorganisms, reliable 3D measurement remains elusive due to the difficulty in imaging fast 3D fluid flows at submicron spatial and millisecond temporal scales. Here, we present a precision measurement of the 3D flow field induced by motile planktonic algae cells, Chlamydomonas reinhardtii. We manually capture and hold stationary a single alga using a micropipette, while still allowing it to beat its flagella in the breastroke pattern characteristic to C. reinhardtii. The 3D flow field around the alga is then tracked by employing fast holographic imaging on 1 um tracer particles, which leads to a spatial resolution of 100 nm along the optical axis and 40 nm in the imaging plane normal to the optical axis. We image the flow around a single alga continuously through thousands of flagellar beat cycles and aggregate that data into a complete 3D flow field. Our study demonstrates the power of holography in imaging fast complex microscopic flow structures and provides crucial information for understanding the detailed locomotion of swimming microorganisms.

  1. Usage of CO2 microbubbles as flow-tracing contrast media in X-ray dynamic imaging of blood flows.

    PubMed

    Lee, Sang Joon; Park, Han Wook; Jung, Sung Yong

    2014-09-01

    X-ray imaging techniques have been employed to visualize various biofluid flow phenomena in a non-destructive manner. X-ray particle image velocimetry (PIV) was developed to measure velocity fields of blood flows to obtain hemodynamic information. A time-resolved X-ray PIV technique that is capable of measuring the velocity fields of blood flows under real physiological conditions was recently developed. However, technical limitations still remained in the measurement of blood flows with high image contrast and sufficient biocapability. In this study, CO2 microbubbles as flow-tracing contrast media for X-ray PIV measurements of biofluid flows was developed. Human serum albumin and CO2 gas were mechanically agitated to fabricate CO2 microbubbles. The optimal fabricating conditions of CO2 microbubbles were found by comparing the size and amount of microbubbles fabricated under various operating conditions. The average size and quantity of CO2 microbubbles were measured by using a synchrotron X-ray imaging technique with a high spatial resolution. The quantity and size of the fabricated microbubbles decrease with increasing speed and operation time of the mechanical agitation. The feasibility of CO2 microbubbles as a flow-tracing contrast media was checked for a 40% hematocrit blood flow. Particle images of the blood flow were consecutively captured by the time-resolved X-ray PIV system to obtain velocity field information of the flow. The experimental results were compared with a theoretically amassed velocity profile. Results show that the CO2 microbubbles can be used as effective flow-tracing contrast media in X-ray PIV experiments.

  2. Assessing potential errors of MRI-based measurements of pulmonary blood flow using a detailed network flow model

    PubMed Central

    Buxton, R. B.; Prisk, G. K.

    2012-01-01

    MRI images of pulmonary blood flow using arterial spin labeling (ASL) measure the delivery of magnetically tagged blood to an image plane during one systolic ejection period. However, the method potentially suffers from two problems, each of which may depend on the imaging plane location: 1) the inversion plane is thicker than the imaging plane, resulting in a gap that blood must cross to be detected in the image; and 2) ASL includes signal contributions from tagged blood in conduit vessels (arterial and venous). By using an in silico model of the pulmonary circulation we found the gap reduced the ASL signal to 64–74% of that in the absence of a gap in the sagittal plane and 53–84% in the coronal. The contribution of the conduit vessels varied markedly as a function of image plane ranging from ∼90% of the overall signal in image planes that encompass the central hilar vessels to <20% in peripheral image planes. A threshold cutoff removing voxels with intensities >35% of maximum reduced the conduit vessel contribution to the total ASL signal to ∼20% on average; however, planes with large contributions from conduit vessels underestimate acinar flow due to a high proportion of in-plane flow, making ASL measurements of perfusion impractical. In other image planes, perfusion dominated the resulting ASL images with good agreement between ASL and acinar flow. Similarly, heterogeneity of the ASL signal as measured by relative dispersion is a reliable measure of heterogeneity of the acinar flow distribution in the same image planes. PMID:22539167

  3. Assessing potential errors of MRI-based measurements of pulmonary blood flow using a detailed network flow model.

    PubMed

    Burrowes, K S; Buxton, R B; Prisk, G K

    2012-07-01

    MRI images of pulmonary blood flow using arterial spin labeling (ASL) measure the delivery of magnetically tagged blood to an image plane during one systolic ejection period. However, the method potentially suffers from two problems, each of which may depend on the imaging plane location: 1) the inversion plane is thicker than the imaging plane, resulting in a gap that blood must cross to be detected in the image; and 2) ASL includes signal contributions from tagged blood in conduit vessels (arterial and venous). By using an in silico model of the pulmonary circulation we found the gap reduced the ASL signal to 64-74% of that in the absence of a gap in the sagittal plane and 53-84% in the coronal. The contribution of the conduit vessels varied markedly as a function of image plane ranging from ∼90% of the overall signal in image planes that encompass the central hilar vessels to <20% in peripheral image planes. A threshold cutoff removing voxels with intensities >35% of maximum reduced the conduit vessel contribution to the total ASL signal to ∼20% on average; however, planes with large contributions from conduit vessels underestimate acinar flow due to a high proportion of in-plane flow, making ASL measurements of perfusion impractical. In other image planes, perfusion dominated the resulting ASL images with good agreement between ASL and acinar flow. Similarly, heterogeneity of the ASL signal as measured by relative dispersion is a reliable measure of heterogeneity of the acinar flow distribution in the same image planes.

  4. Social participation, social support, and body image in the first year of rehabilitation in burn survivors: A longitudinal, three-wave cross-lagged panel analysis using structural equation modeling.

    PubMed

    Ajoudani, Fardin; Jasemi, Madineh; Lotfi, Mojgan

    2018-05-15

    Psychosocial outcomes of burn survivors in the first year of rehabilitation are not well studied. Considering the interrelationships among psychosocial processes in burn survivors, we assessed three psychosocial variables (i.e., social support, social participation, and body image) simultaneously in a longitudinal study. This study aimed at identifying the developmental trajectory of the main study variables and also discovering the causal pathways between social support, body image, and social participation of burn survivors in the first year of rehabilitation. One hundred individuals were enrolled in the study. The analysis was based on three waves of data collected at the time of discharge, 6 months after discharge, and 12 months after discharge. We used MSPSS, SWAP, and the p-scale for measuring the variables social support, body image, and social participation, respectively. A repeated-measures analysis of variance (ANOVA) was performed to identify the major differences in the mean levels of the main study variables across the three evaluation times. A structural equation modeling (SEM) approach was implemented in four hypothesized cross-lagged models (M1, M2, M3, and M4) to evaluate the bidirectional relationships among the main variables. All hypothesized models were tested, and their goodness-of-fit indexes were compared to identify the best fitting model. All three main variables worsen during the first six months after burn and then do not return to their earlier level. The M4 (final model) chosen to represent the data showed the best goodness-of-fit indexes (χ 2 (9)=51.76, p<.01, RMSEA=0.060, IFI=0.97, and CFI=0.98) among all hypothesized models. The effect of social participation on body image, and vice versa, seems to be relatively constant and steady. Social support at the time of discharge predicted social participation at 12 months after burn, with the relationship mediated by body image at 6 months after burn. Our study findings suggest that persistent care should be provided for burn survivors even after discharge. Copyright © 2018 Elsevier Ltd and ISBI. All rights reserved.

  5. Real-time high-velocity resolution color Doppler OCT

    NASA Astrophysics Data System (ADS)

    Westphal, Volker; Yazdanfar, Siavash; Rollins, Andrew M.; Izatt, Joseph A.

    2001-05-01

    Color Doppler optical coherence tomography (CDOCT), also called Optical Doppler Tomography) is a noninvasive optical imaging technique, which allows for micron-scale physiological flow mapping simultaneous with morphological OCT imaging. Current systems for real-time endoscopic optical coherence tomography (EOCT) would be enhanced by the capability to visualize sub-surface blood flow for applications in early cancer diagnosis and the management of bleeding ulcers. Unfortunately, previous implementations of CDOCT have either been sufficiently computationally expensive (employing Fourier or Hilbert transform techniques) to rule out real-time imaging of flow, or have been restricted to imaging of excessively high flow velocities when used in real time. We have developed a novel Doppler OCT signal-processing strategy capable of imaging physiological flow rates in real time. This strategy employs cross-correlation processing of sequential A-scans in an EOCT image, as opposed to autocorrelation processing as described previously. To measure Doppler shifts in the kHz range using this technique, it was necessary to stabilize the EOCT interferometer center frequency, eliminate parasitic phase noise, and to construct a digital cross correlation unit able to correlate signals of megahertz bandwidth by a fixed lag of up to a few ms. The performance of the color Doppler OCT system was demonstrated in a flow phantom, demonstrating a minimum detectable flow velocity of ~0.8 mm/s at a data acquisition rate of 8 images/second (with 480 A-scans/image) using a handheld probe. Dynamic flow as well as using it freehanded was shown. Flow was also detectable in a phantom in combination with a clinical usable endoscopic probe.

  6. The Toxicity of Inhaled Sulphur Mustard

    DTIC Science & Technology

    2012-03-01

    Pulse oximetry Mean arterial pressure Central venous pressure Blood Chemistry (arterial and venous ) pH pO2 pCO2 Sodium Potassium Calcium...Cardiovascular Parameters − CFI – Cardiac Function Index − CO – Cardiac Output − CvO2 – Mixed Venous Oxygenation − CVP – Central Venous Pressure...Data are expressed as mean ± SEM. Changes in central venous pressure following exposure to HD: HD controls () and HD + NAC (). Data are

  7. Stereoscopic Planar Laser-Induced Fluorescence Imaging at 500 kHz

    NASA Technical Reports Server (NTRS)

    Medford, Taylor L.; Danehy, Paul M.; Jones, Stephen B.; Jiang, N.; Webster, M.; Lempert, Walter; Miller, J.; Meyer, T.

    2011-01-01

    A new measurement technique for obtaining time- and spatially-resolved image sequences in hypersonic flows is developed. Nitric-oxide planar laser-induced fluorescence (NO PLIF) has previously been used to investigate transition from laminar to turbulent flow in hypersonic boundary layers using both planar and volumetric imaging capabilities. Low flow rates of NO were typically seeded into the flow, minimally perturbing the flow. The volumetric imaging was performed at a measurement rate of 10 Hz using a thick planar laser sheet that excited NO fluorescence. The fluorescence was captured by a pair of cameras having slightly different views of the flow. Subsequent stereoscopic reconstruction of these images allowed the three-dimensional flow structures to be viewed. In the current paper, this approach has been extended to 50,000 times higher repetition rates. A laser operating at 500 kHz excites the seeded NO molecules, and a camera, synchronized with the laser and fitted with a beam-splitting assembly, acquires two separate images of the flow. The resulting stereoscopic images provide three-dimensional flow visualizations at 500 kHz for the first time. The 200 ns exposure time in each frame is fast enough to freeze the flow while the 500 kHz repetition rate is fast enough to time-resolve changes in the flow being studied. This method is applied to visualize the evolving hypersonic flow structures that propagate downstream of a discrete protuberance attached to a flat plate. The technique was demonstrated in the NASA Langley Research Center s 31-Inch Mach 10 Air Tunnel facility. Different tunnel Reynolds number conditions, NO flow rates and two different cylindrical protuberance heights were investigated. The location of the onset of flow unsteadiness, an indicator of transition, was observed to move downstream during the tunnel runs, coinciding with an increase in the model temperature.

  8. Intraoperative laser speckle contrast imaging for monitoring cerebral blood flow: results from a 10-patient pilot study

    NASA Astrophysics Data System (ADS)

    Richards, Lisa M.; Weber, Erica L.; Parthasarathy, Ashwin B.; Kappeler, Kaelyn L.; Fox, Douglas J.; Dunn, Andrew K.

    2012-02-01

    Monitoring cerebral blood flow (CBF) during neurosurgery can provide important physiological information for a variety of surgical procedures. Although multiple intraoperative vascular monitoring technologies are currently available, a quantitative method that allows for continuous monitoring is still needed. Laser speckle contrast imaging (LSCI) is an optical imaging method with high spatial and temporal resolution that has been widely used to image CBF in animal models in vivo. In this pilot clinical study, we adapted a Zeiss OPMI Pentero neurosurgical microscope to obtain LSCI images by attaching a camera and a laser diode. This LSCI adapted instrument has been used to acquire full field flow images from 10 patients during tumor resection procedures. The patient's ECG was recorded during acquisition and image registration was performed in post-processing to account for pulsatile motion artifacts. Digital photographs confirmed alignment of vasculature and flow images in four cases, and a relative change in blood flow was observed in two patients after bipolar cautery. The LSCI adapted instrument has the capability to produce real-time, full field CBF image maps with excellent spatial resolution and minimal intervention to the surgical procedure. Results from this study demonstrate the feasibility of using LSCI to monitor blood flow during neurosurgery.

  9. Enhanced Line Integral Convolution with Flow Feature Detection

    NASA Technical Reports Server (NTRS)

    Lane, David; Okada, Arthur

    1996-01-01

    The Line Integral Convolution (LIC) method, which blurs white noise textures along a vector field, is an effective way to visualize overall flow patterns in a 2D domain. The method produces a flow texture image based on the input velocity field defined in the domain. Because of the nature of the algorithm, the texture image tends to be blurry. This sometimes makes it difficult to identify boundaries where flow separation and reattachments occur. We present techniques to enhance LIC texture images and use colored texture images to highlight flow separation and reattachment boundaries. Our techniques have been applied to several flow fields defined in 3D curvilinear multi-block grids and scientists have found the results to be very useful.

  10. X-ray Microtomography of Intermittency in Multiphase Flow at Steady State Using a Differential Imaging Method

    NASA Astrophysics Data System (ADS)

    Gao, Ying; Lin, Qingyang; Bijeljic, Branko; Blunt, Martin J.

    2017-12-01

    We imaged the steady state flow of brine and decane in Bentheimer sandstone. We devised an experimental method based on differential imaging to examine how flow rate impacts impact the pore-scale distribution of fluids during coinjection. This allows us to elucidate flow regimes (connected, or breakup of the nonwetting phase pathways) for a range of fractional flows at two capillary numbers, Ca, namely 3.0 × 10-7 and 7.5 × 10-6. At the lower Ca, for a fixed fractional flow, the two phases appear to flow in connected unchanging subnetworks of the pore space, consistent with conventional theory. At the higher Ca, we observed that a significant fraction of the pore space contained sometimes oil and sometimes brine during the 1 h scan: this intermittent occupancy, which was interpreted as regions of the pore space that contained both fluid phases for some time, is necessary to explain the flow and dynamic connectivity of the oil phase; pathways of always oil-filled portions of the void space did not span the core. This phase was segmented from the differential image between the 30 wt % KI brine image and the scans taken at each fractional flow. Using the grey scale histogram distribution of the raw images, the oil proportion in the intermittent phase was calculated. The pressure drops at each fractional flow at low and high flow rates were measured by high-precision differential pressure sensors. The relative permeabilities and fractional flow obtained by our experiment at the mm-scale compare well with data from the literature on cm-scale samples.

  11. Low-cost laser speckle contrast imaging of blood flow using a webcam.

    PubMed

    Richards, Lisa M; Kazmi, S M Shams; Davis, Janel L; Olin, Katherine E; Dunn, Andrew K

    2013-01-01

    Laser speckle contrast imaging has become a widely used tool for dynamic imaging of blood flow, both in animal models and in the clinic. Typically, laser speckle contrast imaging is performed using scientific-grade instrumentation. However, due to recent advances in camera technology, these expensive components may not be necessary to produce accurate images. In this paper, we demonstrate that a consumer-grade webcam can be used to visualize changes in flow, both in a microfluidic flow phantom and in vivo in a mouse model. A two-camera setup was used to simultaneously image with a high performance monochrome CCD camera and the webcam for direct comparison. The webcam was also tested with inexpensive aspheric lenses and a laser pointer for a complete low-cost, compact setup ($90, 5.6 cm length, 25 g). The CCD and webcam showed excellent agreement with the two-camera setup, and the inexpensive setup was used to image dynamic blood flow changes before and after a targeted cerebral occlusion.

  12. Low-cost laser speckle contrast imaging of blood flow using a webcam

    PubMed Central

    Richards, Lisa M.; Kazmi, S. M. Shams; Davis, Janel L.; Olin, Katherine E.; Dunn, Andrew K.

    2013-01-01

    Laser speckle contrast imaging has become a widely used tool for dynamic imaging of blood flow, both in animal models and in the clinic. Typically, laser speckle contrast imaging is performed using scientific-grade instrumentation. However, due to recent advances in camera technology, these expensive components may not be necessary to produce accurate images. In this paper, we demonstrate that a consumer-grade webcam can be used to visualize changes in flow, both in a microfluidic flow phantom and in vivo in a mouse model. A two-camera setup was used to simultaneously image with a high performance monochrome CCD camera and the webcam for direct comparison. The webcam was also tested with inexpensive aspheric lenses and a laser pointer for a complete low-cost, compact setup ($90, 5.6 cm length, 25 g). The CCD and webcam showed excellent agreement with the two-camera setup, and the inexpensive setup was used to image dynamic blood flow changes before and after a targeted cerebral occlusion. PMID:24156082

  13. Fast X-ray imaging of cavitating flows

    DOE PAGES

    Khlifa, Ilyass; Vabre, Alexandre; Hočevar, Marko; ...

    2017-10-20

    A new method based on ultra-fast X-ray imaging was developed in this work for simultaneous investigations of the dynamics and the structures of complex two-phase flows. Here in this paper, cavitation was created inside a millimetric 2D Venturi-type test section, while seeding particles were injected into the flow. Thanks to the phase-contrast enhancement technique provided by the APS (Advanced Photon Source) synchrotron beam, high definition X-ray images of the complex cavitating flows were obtained. These images contain valuable information about both the liquid and the gaseous phases. By means of image processing, the two phases were separated, and velocity fieldsmore » of each phase were therefore calculated using image cross-correlations. The local vapour volume fractions were also obtained thanks to the local intensity levels within the recorded images. These simultaneous measurements, provided by this new technique, afford more insight into the structure and the dynamic of two-phase flows as well as the interactions between then, and hence enable to improve our understanding of their behavior. In the case of cavitating flows inside a Venturi-type test section, the X-ray measurements demonstrates, for the first time, the presence of significant slip velocities between the phases within sheet cavities for both steady and unsteady flow configurations.« less

  14. Fast X-ray imaging of cavitating flows

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khlifa, Ilyass; Vabre, Alexandre; Hočevar, Marko

    A new method based on ultra-fast X-ray imaging was developed in this work for simultaneous investigations of the dynamics and the structures of complex two-phase flows. Here in this paper, cavitation was created inside a millimetric 2D Venturi-type test section, while seeding particles were injected into the flow. Thanks to the phase-contrast enhancement technique provided by the APS (Advanced Photon Source) synchrotron beam, high definition X-ray images of the complex cavitating flows were obtained. These images contain valuable information about both the liquid and the gaseous phases. By means of image processing, the two phases were separated, and velocity fieldsmore » of each phase were therefore calculated using image cross-correlations. The local vapour volume fractions were also obtained thanks to the local intensity levels within the recorded images. These simultaneous measurements, provided by this new technique, afford more insight into the structure and the dynamic of two-phase flows as well as the interactions between then, and hence enable to improve our understanding of their behavior. In the case of cavitating flows inside a Venturi-type test section, the X-ray measurements demonstrates, for the first time, the presence of significant slip velocities between the phases within sheet cavities for both steady and unsteady flow configurations.« less

  15. Microfluidic Imaging Flow Cytometry by Asymmetric-detection Time-stretch Optical Microscopy (ATOM).

    PubMed

    Tang, Anson H L; Lai, Queenie T K; Chung, Bob M F; Lee, Kelvin C M; Mok, Aaron T Y; Yip, G K; Shum, Anderson H C; Wong, Kenneth K Y; Tsia, Kevin K

    2017-06-28

    Scaling the number of measurable parameters, which allows for multidimensional data analysis and thus higher-confidence statistical results, has been the main trend in the advanced development of flow cytometry. Notably, adding high-resolution imaging capabilities allows for the complex morphological analysis of cellular/sub-cellular structures. This is not possible with standard flow cytometers. However, it is valuable for advancing our knowledge of cellular functions and can benefit life science research, clinical diagnostics, and environmental monitoring. Incorporating imaging capabilities into flow cytometry compromises the assay throughput, primarily due to the limitations on speed and sensitivity in the camera technologies. To overcome this speed or throughput challenge facing imaging flow cytometry while preserving the image quality, asymmetric-detection time-stretch optical microscopy (ATOM) has been demonstrated to enable high-contrast, single-cell imaging with sub-cellular resolution, at an imaging throughput as high as 100,000 cells/s. Based on the imaging concept of conventional time-stretch imaging, which relies on all-optical image encoding and retrieval through the use of ultrafast broadband laser pulses, ATOM further advances imaging performance by enhancing the image contrast of unlabeled/unstained cells. This is achieved by accessing the phase-gradient information of the cells, which is spectrally encoded into single-shot broadband pulses. Hence, ATOM is particularly advantageous in high-throughput measurements of single-cell morphology and texture - information indicative of cell types, states, and even functions. Ultimately, this could become a powerful imaging flow cytometry platform for the biophysical phenotyping of cells, complementing the current state-of-the-art biochemical-marker-based cellular assay. This work describes a protocol to establish the key modules of an ATOM system (from optical frontend to data processing and visualization backend), as well as the workflow of imaging flow cytometry based on ATOM, using human cells and micro-algae as the examples.

  16. Evaluation of contrast-enhanced power Doppler imaging for measuring blood flow

    NASA Astrophysics Data System (ADS)

    Ansaloni, Sara; Arger, Peter H.; Cary, Ted W.; Sehgal, Chandra M.

    2005-04-01

    Power Doppler ultrasound enhanced by microbubble contrast agent has been used to image tissue vascularity and blood flow for the assessment of antivascular therapies. We have proposed a multigating technique that measures bubble concentration as a function of ultrasound exposure for deriving tumor blood flow and vascularity.1 Techniques using ultrasound contrast agent are known to be sensitive to the choice of imaging parameters like mechanical index and tissue attenuation. In this paper, the roles of mechanical index (MI) and tissue attenuation were evaluated experimentally in a rubber tubing flow phantom connected to a mixing chamber and a variable speed pump. The contrast was injected in the mixing chamber and the flow rate was measured using power Doppler imaging. The measurements were repeated at different MIs (0.1 to 1.3), and at different levels of attenuation, obtained with solutions of glycerol-water (10-20%). True flow was measured by collecting liquid flowing out of the phantom over a fixed duration. At low MI (<0.5), the grayscale and Doppler signal were weak, making these images unsuitable for analysis. At higher MI (> 0.8), there was a well-defined enhancement by contrast agent resulting in reproducible flow measurements at variable MIs. A balance between the number of bubbles destroyed and the echo they generate must be achieved for optimal imaging. The increased attenuation of ultrasound by the overlying medium did not influence the flow measurements.

  17. High throughput, parallel imaging and biomarker quantification of human spermatozoa by ImageStream flow cytometry.

    PubMed

    Buckman, Clayton; George, Thaddeus C; Friend, Sherree; Sutovsky, Miriam; Miranda-Vizuete, Antonio; Ozanon, Christophe; Morrissey, Phil; Sutovsky, Peter

    2009-12-01

    Spermatid specific thioredoxin-3 protein (SPTRX-3) accumulates in the superfluous cytoplasm of defective human spermatozoa. Novel ImageStream technology combining flow cytometry with cell imaging was used for parallel quantification and visualization of SPTRX-3 protein in defective spermatozoa of five men from infertile couples. The majority of the SPTRX-3 containing cells were overwhelmingly spermatozoa with a variety of morphological defects, detectable in the ImageStream recorded images. Quantitative parameters of relative SPTRX-3 induced fluorescence measured by ImageStream correlated closely with conventional flow cytometric measurements of the same sample set and reflected the results of clinical semen evaluation. Image Stream quantification of SPTRX-3 combines and surpasses the informative value of both conventional flow cytometry and light microscopic semen evaluation. The observed patterns of the retention of SPTRX-3 in the sperm samples from infertility patients support the view that SPTRX3 is a biomarker of male infertility.

  18. Dynamic three-dimensional phase-contrast technique in MRI: application to complex flow analysis around the artificial heart valve

    NASA Astrophysics Data System (ADS)

    Kim, Soo Jeong; Lee, Dong Hyuk; Song, Inchang; Kim, Nam Gook; Park, Jae-Hyeung; Kim, JongHyo; Han, Man Chung; Min, Byong Goo

    1998-07-01

    Phase-contrast (PC) method of magnetic resonance imaging (MRI) has bee used for quantitative measurements of flow velocity and volume flow rate. It is a noninvasive technique which provides an accurate two-dimensional velocity image. Moreover, Phase Contrast Cine magnetic resonance imaging combines the flow dependent contrast of PC-MRI with the ability of cardiac cine imaging to produce images throughout the cardiac cycle. However, the accuracy of the data acquired from the single through-plane velocity encoding can be reduced by the effect of flow direction, because in many practical cases flow directions are not uniform throughout the whole region of interest. In this study, we present dynamic three-dimensional velocity vector mapping method using PC-MRI which can visualize the complex flow pattern through 3D volume rendered images displayed dynamically. The direction of velocity mapping can be selected along any three orthogonal axes. By vector summation, the three maps can be combined to form a velocity vector map that determines the velocity regardless of the flow direction. At the same time, Cine method is used to observe the dynamic change of flow. We performed a phantom study to evaluate the accuracy of the suggested PC-MRI in continuous and pulsatile flow measurement. Pulsatile flow wave form is generated by the ventricular assistant device (VAD), HEMO-PULSA (Biomedlab, Seoul, Korea). We varied flow velocity, pulsatile flow wave form, and pulsing rate. The PC-MRI-derived velocities were compared with Doppler-derived results. The velocities of the two measurements showed a significant linear correlation. Dynamic three-dimensional velocity vector mapping was carried out for two cases. First, we applied to the flow analysis around the artificial heart valve in a flat phantom. We could observe the flow pattern around the valve through the 3-dimensional cine image. Next, it is applied to the complex flow inside the polymer sac that is used as ventricle in totally implantable artificial heart (TAH). As a result we could observe the flow pattern around the valves of the sac, though complex flow can not be detected correctly in the conventional phase contrast method. In addition, we could calculate the cardiac output from TAH sac by quantitative measurement of the volume of flow across the outlet valve.

  19. [Distribution, population parameters, and diet of Astropecten marginatus (Asteroidea: Astropectinidae) in the Venezuelan Atlantic coast].

    PubMed

    Ortega, Ileana; Martín, Alberto; Díaz, Yusbelly

    2011-03-01

    Astropecten marginatus is a sea star widely distributed in Northern and Eastern South America, found on sandy and muddy bottoms, in shallow and deep waters. To describe some of its ecological characteristics, we calculated it spatial-temporal distribution, population parameters (based on size and weight) and diet in the Orinoco Delta ecoregion (Venezuela). The ecoregion was divided in three sections: Golfo de Paria, Boca de Serpiente and Plataforma Deltana. Samples for the rainy and dry seasons came from megabenthos surveys of the "Línea Base Ambiental Plataforma Deltana (LBAPD)" and "Corocoro Fase I (CFI)" projects. The collected sea stars were measured, weighted and dissected by the oral side to extract their stomach and identify the preys consumed. A total of 570 sea stars were collected in LBAPD project and 306 in CFI one. The highest densities were found during the dry season in almost all sections. In LBAPD project the highest density was in "Plataforma Deltana" section (0.007 +/- 0.022 ind/m2 in dry season and 0.014 +/- 0.06 ind/m2 in rainy season) and in the CFI project the densities in "Golfo de Paria" section were 0.705 +/- 0.829 ind/m2 in rainy season and 1.027 +/- 1.107 ind/m2 in dry season. The most frequent size range was 3.1-4.6cm. The highest biomass was found in "Golfo de Paria" section (7.581 +/- 0.018 mg/m2 in dry season and 0.005 +/- 6.542 x 10(-06) mg/m2 in rainy season for 2004-2005 and 3.979 +/- 4.024 mg/m2 in dry season; and 3.117 +/- 3.137 mg/m2 in rainy season for 2006). A linear relationship was found between the sea star size and its weight but no relationship was observed between its size and the depth where it was collected. Mollusks are dominant in the sea star diet (47.4% in abundance). The diet in any of the sections, seasons or between projects or size class was heterogeneous, using multivariate ordinations (MDS) and SIMPER analysis and there was no difference in the prey number or food elements that a sea star can eat. Although A. marginatus has been described as a predator, in this study were also inferred scavenger and detritivorous habits.

  20. Clinical review: Efficacy of antimicrobial-impregnated catheters in external ventricular drainage - a systematic review and meta-analysis.

    PubMed

    Wang, Xiang; Dong, Yan; Qi, Xiang-Qian; Li, Yi-Ming; Huang, Cheng-Guang; Hou, Li-Jun

    2013-07-25

    To assess the efficacy of antimicrobial-impregnated catheters in preventing catheter-related infections during external ventricular drainage (EVD), we performed a meta-analysis and systematic review. We systematically searched Medline, Embase, and the Cochrane Library. All randomized controlled trials (RCTs) and nonrandomized prospective studies (NPSs) related to antimicrobial-impregnated EVD catheters were included. The primary outcome was the rate of cerebrospinal fluid infection (CFI). The secondary outcomes included the rate of time-dependent CFI and catheter bacterial colonization. We further performed subgroup analysis, meta-regression analysis, and microbial spectrum analysis. Four RCTs and four NPSs were included. The overall rate of CFIs was 3.6% in the antimicrobial-impregnated catheter group and 13.7% in the standard catheter group. The pooled data demonstrated that antimicrobial-impregnated catheters were superior to standard catheters in lowering the rate of CFIs (odds ratio (OR) = 0.25, 95% confidence interval (CI) = 0.12 to 0.52, P <0.05). In survival analysis, the 20-day infection rate was significantly reduced with the use of antimicrobial-impregnated catheters (hazard ratio = 0.52, 95% CI = 0.29 to 0.95, P <0.05). Furthermore, a significantly decreased rate of catheter bacterial colonization was noticed for antimicrobial-impregnated catheters (OR = 0.37, 95% CI = 0.21 to 0.64, P <0.05). In subgroup analyses, although significant results remained for RCTs and NPSs, a subgroup difference was revealed (P <0.05). Compared with standard catheters, a significantly lower rate of CFIs was noticed for clindamycin/rifampin-impregnated catheters (OR = 0.27, 95% CI = 0.10 to 0.73, P <0.05) and for minocycline/rifampin-impregnated catheters (OR = 0.11, 95% CI = 0.06 to 0.21, P <0.05). However, no statistical significance was found when compared with silver-impregnated catheters (OR = 0.33, 95% CI = 0.07 to 1.69, P = 0.18). In microbial spectrum analysis, antimicrobial-impregnated catheters were shown to have a lower rate of Gram-positive bacterial infection, particularly the coagulase-negative Staphylococcus. In conclusion, the use of antimicrobial-impregnated EVD catheters could be beneficial for the prevention of CFI and catheter bacterial colonization. Although antibiotic-coated catheters seem to be effective, no sufficient evidence supports the efficacy of silver-impregnated catheters.

  1. Clinical review: Efficacy of antimicrobial-impregnated catheters in external ventricular drainage - a systematic review and meta-analysis

    PubMed Central

    2013-01-01

    To assess the efficacy of antimicrobial-impregnated catheters in preventing catheter-related infections during external ventricular drainage (EVD), we performed a meta-analysis and systematic review. We systematically searched Medline, Embase, and the Cochrane Library. All randomized controlled trials (RCTs) and nonrandomized prospective studies (NPSs) related to antimicrobial-impregnated EVD catheters were included. The primary outcome was the rate of cerebrospinal fluid infection (CFI). The secondary outcomes included the rate of time-dependent CFI and catheter bacterial colonization. We further performed subgroup analysis, meta-regression analysis, and microbial spectrum analysis. Four RCTs and four NPSs were included. The overall rate of CFIs was 3.6% in the antimicrobial-impregnated catheter group and 13.7% in the standard catheter group. The pooled data demonstrated that antimicrobial-impregnated catheters were superior to standard catheters in lowering the rate of CFIs (odds ratio (OR) = 0.25, 95% confidence interval (CI) = 0.12 to 0.52, P <0.05). In survival analysis, the 20-day infection rate was significantly reduced with the use of antimicrobial-impregnated catheters (hazard ratio = 0.52, 95% CI = 0.29 to 0.95, P <0.05). Furthermore, a significantly decreased rate of catheter bacterial colonization was noticed for antimicrobial-impregnated catheters (OR = 0.37, 95% CI = 0.21 to 0.64, P <0.05). In subgroup analyses, although significant results remained for RCTs and NPSs, a subgroup difference was revealed (P <0.05). Compared with standard catheters, a significantly lower rate of CFIs was noticed for clindamycin/rifampin-impregnated catheters (OR = 0.27, 95% CI = 0.10 to 0.73, P <0.05) and for minocycline/rifampin-impregnated catheters (OR = 0.11, 95% CI = 0.06 to 0.21, P <0.05). However, no statistical significance was found when compared with silver-impregnated catheters (OR = 0.33, 95% CI = 0.07 to 1.69, P = 0.18). In microbial spectrum analysis, antimicrobial-impregnated catheters were shown to have a lower rate of Gram-positive bacterial infection, particularly the coagulase-negative Staphylococcus. In conclusion, the use of antimicrobial-impregnated EVD catheters could be beneficial for the prevention of CFI and catheter bacterial colonization. Although antibiotic-coated catheters seem to be effective, no sufficient evidence supports the efficacy of silver-impregnated catheters. PMID:23890254

  2. Three-dimensional quantitative flow diagnostics

    NASA Technical Reports Server (NTRS)

    Miles, Richard B.; Nosenchuck, Daniel M.

    1989-01-01

    The principles, capabilities, and practical implementation of advanced measurement techniques for the quantitative characterization of three-dimensional flows are reviewed. Consideration is given to particle, Rayleigh, and Raman scattering; fluorescence; flow marking by H2 bubbles, photochromism, photodissociation, and vibrationally excited molecules; light-sheet volume imaging; and stereo imaging. Also discussed are stereo schlieren methods, holographic particle imaging, optical tomography, acoustic and magnetic-resonance imaging, and the display of space-filling data. Extensive diagrams, graphs, photographs, sample images, and tables of numerical data are provided.

  3. Asymmetric-detection time-stretch optical microscopy (ATOM) for ultrafast high-contrast cellular imaging in flow

    PubMed Central

    Wong, Terence T. W.; Lau, Andy K. S.; Ho, Kenneth K. Y.; Tang, Matthew Y. H.; Robles, Joseph D. F.; Wei, Xiaoming; Chan, Antony C. S.; Tang, Anson H. L.; Lam, Edmund Y.; Wong, Kenneth K. Y.; Chan, Godfrey C. F.; Shum, Ho Cheung; Tsia, Kevin K.

    2014-01-01

    Accelerating imaging speed in optical microscopy is often realized at the expense of image contrast, image resolution, and detection sensitivity – a common predicament for advancing high-speed and high-throughput cellular imaging. We here demonstrate a new imaging approach, called asymmetric-detection time-stretch optical microscopy (ATOM), which can deliver ultrafast label-free high-contrast flow imaging with well delineated cellular morphological resolution and in-line optical image amplification to overcome the compromised imaging sensitivity at high speed. We show that ATOM can separately reveal the enhanced phase-gradient and absorption contrast in microfluidic live-cell imaging at a flow speed as high as ~10 m/s, corresponding to an imaging throughput of ~100,000 cells/sec. ATOM could thus be the enabling platform to meet the pressing need for intercalating optical microscopy in cellular assay, e.g. imaging flow cytometry – permitting high-throughput access to the morphological information of the individual cells simultaneously with a multitude of parameters obtained in the standard assay. PMID:24413677

  4. Multi-phase imaging of intermittency at steady state using differential imaging method by X-ray micro-tomography

    NASA Astrophysics Data System (ADS)

    Gao, Y.; Lin, Q.; Bijeljic, B.; Blunt, M. J.

    2017-12-01

    To observe intermittency in consolidated rock, we image a steady state flow of brine and decane in Bentheimer sandstone. We devise an experimental method based on X-ray differential imaging method to examine how changes in flow rate impact the pore-scale distribution of fluids during co-injection flow under dynamic flow conditions at steady state. This helps us elucidate the diverse flow regimes (connected, intermittent break-up, or continual break-up of the non-wetting phase pathways) for two capillary numbers. Also, relative permeability curves under both capillary and viscous limited conditions could be measured. We have performed imbibition sample floods using oil-brine and measured steady state relative permeability on a sandstone rock core in order to fully characterize the flow behaviour at low and high Ca. Two sets of experiments at high and low flow rates are provided to explore the time-evolution of the non-wetting phase clusters distribution under different flow conditions. The high flow rate is 0.5 mL/min, whose corresponding capillary number is 7.7×10-6. The low flow rate is 0.02 mL/min, whose capillary number is 3.1×10-7. A procedure based on using high-salinity brine as the contrast phase and applying differential imaging between the dry scan and that of the sample saturation with a 30 wt% Potassium iodide (KI) doped brine help to make sure there is no non-wetting phase in micro-pores. Then the intermittent phase in multiphase flow image at high Ca can be quantified by obtaining the differential image between the 30 wt% KI brine image and the scans that taken at each fixed fractional flow. By using the grey scale histogram distribution of the raw images at each condition, the oil proportion in the intermittent phase can be calculated. The pressure drops at each fractional flow at low and high Ca can be measured by high-precision pressure differential sensors and utilized to calculate to the relative permeability at pore scale. The relative permeability data and fw-Sw relationship obtained by our experiment at pore scale are compared with the data collected from experiments which were conducted at core scale, and they match well.

  5. Grouping of optic flow stimuli during binocular rivalry is driven by monocular information.

    PubMed

    Holten, Vivian; Stuit, Sjoerd M; Verstraten, Frans A J; van der Smagt, Maarten J

    2016-10-01

    During binocular rivalry, perception alternates between two dissimilar images, presented dichoptically. Although binocular rivalry is thought to result from competition at a local level, neighboring image parts with similar features tend to be perceived together for longer durations than image parts with dissimilar features. This simultaneous dominance of two image parts is called grouping during rivalry. Previous studies have shown that this grouping depends on a shared eye-of-origin to a much larger extent than on image content, irrespective of the complexity of a static image. In the current study, we examine whether grouping of dynamic optic flow patterns is also primarily driven by monocular (eye-of-origin) information. In addition, we examine whether image parameters, such as optic flow direction, and partial versus full visibility of the optic flow pattern, affect grouping durations during rivalry. The results show that grouping of optic flow is, as is known for static images, primarily affected by its eye-of-origin. Furthermore, global motion can affect grouping durations, but only under specific conditions. Namely, only when the two full optic flow patterns were presented locally. These results suggest that grouping during rivalry is primarily driven by monocular information even for motion stimuli thought to rely on higher-level motion areas. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Human pose tracking from monocular video by traversing an image motion mapped body pose manifold

    NASA Astrophysics Data System (ADS)

    Basu, Saurav; Poulin, Joshua; Acton, Scott T.

    2010-01-01

    Tracking human pose from monocular video sequences is a challenging problem due to the large number of independent parameters affecting image appearance and nonlinear relationships between generating parameters and the resultant images. Unlike the current practice of fitting interpolation functions to point correspondences between underlying pose parameters and image appearance, we exploit the relationship between pose parameters and image motion flow vectors in a physically meaningful way. Change in image appearance due to pose change is realized as navigating a low dimensional submanifold of the infinite dimensional Lie group of diffeomorphisms of the two dimensional sphere S2. For small changes in pose, image motion flow vectors lie on the tangent space of the submanifold. Any observed image motion flow vector field is decomposed into the basis motion vector flow fields on the tangent space and combination weights are used to update corresponding pose changes in the different dimensions of the pose parameter space. Image motion flow vectors are largely invariant to style changes in experiments with synthetic and real data where the subjects exhibit variation in appearance and clothing. The experiments demonstrate the robustness of our method (within +/-4° of ground truth) to style variance.

  7. Testing random forest classification for identifying lava flows and mapping age groups on a single Landsat 8 image

    NASA Astrophysics Data System (ADS)

    Li, Long; Solana, Carmen; Canters, Frank; Kervyn, Matthieu

    2017-10-01

    Mapping lava flows using satellite images is an important application of remote sensing in volcanology. Several volcanoes have been mapped through remote sensing using a wide range of data, from optical to thermal infrared and radar images, using techniques such as manual mapping, supervised/unsupervised classification, and elevation subtraction. So far, spectral-based mapping applications mainly focus on the use of traditional pixel-based classifiers, without much investigation into the added value of object-based approaches and into advantages of using machine learning algorithms. In this study, Nyamuragira, characterized by a series of > 20 overlapping lava flows erupted over the last century, was used as a case study. The random forest classifier was tested to map lava flows based on pixels and objects. Image classification was conducted for the 20 individual flows and for 8 groups of flows of similar age using a Landsat 8 image and a DEM of the volcano, both at 30-meter spatial resolution. Results show that object-based classification produces maps with continuous and homogeneous lava surfaces, in agreement with the physical characteristics of lava flows, while lava flows mapped through the pixel-based classification are heterogeneous and fragmented including much "salt and pepper noise". In terms of accuracy, both pixel-based and object-based classification performs well but the former results in higher accuracies than the latter except for mapping lava flow age groups without using topographic features. It is concluded that despite spectral similarity, lava flows of contrasting age can be well discriminated and mapped by means of image classification. The classification approach demonstrated in this study only requires easily accessible image data and can be applied to other volcanoes as well if there is sufficient information to calibrate the mapping.

  8. Real-time blood flow visualization using the graphics processing unit

    NASA Astrophysics Data System (ADS)

    Yang, Owen; Cuccia, David; Choi, Bernard

    2011-01-01

    Laser speckle imaging (LSI) is a technique in which coherent light incident on a surface produces a reflected speckle pattern that is related to the underlying movement of optical scatterers, such as red blood cells, indicating blood flow. Image-processing algorithms can be applied to produce speckle flow index (SFI) maps of relative blood flow. We present a novel algorithm that employs the NVIDIA Compute Unified Device Architecture (CUDA) platform to perform laser speckle image processing on the graphics processing unit. Software written in C was integrated with CUDA and integrated into a LabVIEW Virtual Instrument (VI) that is interfaced with a monochrome CCD camera able to acquire high-resolution raw speckle images at nearly 10 fps. With the CUDA code integrated into the LabVIEW VI, the processing and display of SFI images were performed also at ~10 fps. We present three video examples depicting real-time flow imaging during a reactive hyperemia maneuver, with fluid flow through an in vitro phantom, and a demonstration of real-time LSI during laser surgery of a port wine stain birthmark.

  9. Real-time blood flow visualization using the graphics processing unit

    PubMed Central

    Yang, Owen; Cuccia, David; Choi, Bernard

    2011-01-01

    Laser speckle imaging (LSI) is a technique in which coherent light incident on a surface produces a reflected speckle pattern that is related to the underlying movement of optical scatterers, such as red blood cells, indicating blood flow. Image-processing algorithms can be applied to produce speckle flow index (SFI) maps of relative blood flow. We present a novel algorithm that employs the NVIDIA Compute Unified Device Architecture (CUDA) platform to perform laser speckle image processing on the graphics processing unit. Software written in C was integrated with CUDA and integrated into a LabVIEW Virtual Instrument (VI) that is interfaced with a monochrome CCD camera able to acquire high-resolution raw speckle images at nearly 10 fps. With the CUDA code integrated into the LabVIEW VI, the processing and display of SFI images were performed also at ∼10 fps. We present three video examples depicting real-time flow imaging during a reactive hyperemia maneuver, with fluid flow through an in vitro phantom, and a demonstration of real-time LSI during laser surgery of a port wine stain birthmark. PMID:21280915

  10. Study on polarized optical flow algorithm for imaging bionic polarization navigation micro sensor

    NASA Astrophysics Data System (ADS)

    Guan, Le; Liu, Sheng; Li, Shi-qi; Lin, Wei; Zhai, Li-yuan; Chu, Jin-kui

    2018-05-01

    At present, both the point source and the imaging polarization navigation devices only can output the angle information, which means that the velocity information of the carrier cannot be extracted from the polarization field pattern directly. Optical flow is an image-based method for calculating the velocity of pixel point movement in an image. However, for ordinary optical flow, the difference in pixel value as well as the calculation accuracy can be reduced in weak light. Polarization imaging technology has the ability to improve both the detection accuracy and the recognition probability of the target because it can acquire the extra polarization multi-dimensional information of target radiation or reflection. In this paper, combining the polarization imaging technique with the traditional optical flow algorithm, a polarization optical flow algorithm is proposed, and it is verified that the polarized optical flow algorithm has good adaptation in weak light and can improve the application range of polarization navigation sensors. This research lays the foundation for day and night all-weather polarization navigation applications in future.

  11. Breaking camouflage and detecting targets require optic flow and image structure information.

    PubMed

    Pan, Jing Samantha; Bingham, Ned; Chen, Chang; Bingham, Geoffrey P

    2017-08-01

    Use of motion to break camouflage extends back to the Cambrian [In the Blink of an Eye: How Vision Sparked the Big Bang of Evolution (New York Basic Books, 2003)]. We investigated the ability to break camouflage and continue to see camouflaged targets after motion stops. This is crucial for the survival of hunting predators. With camouflage, visual targets and distracters cannot be distinguished using only static image structure (i.e., appearance). Motion generates another source of optical information, optic flow, which breaks camouflage and specifies target locations. Optic flow calibrates image structure with respect to spatial relations among targets and distracters, and calibrated image structure makes previously camouflaged targets perceptible in a temporally stable fashion after motion stops. We investigated this proposal using laboratory experiments and compared how many camouflaged targets were identified either with optic flow information alone or with combined optic flow and image structure information. Our results show that the combination of motion-generated optic flow and target-projected image structure information yielded efficient and stable perception of camouflaged targets.

  12. Handheld Fluorescence Microscopy based Flow Analyzer.

    PubMed

    Saxena, Manish; Jayakumar, Nitin; Gorthi, Sai Siva

    2016-03-01

    Fluorescence microscopy has the intrinsic advantages of favourable contrast characteristics and high degree of specificity. Consequently, it has been a mainstay in modern biological inquiry and clinical diagnostics. Despite its reliable nature, fluorescence based clinical microscopy and diagnostics is a manual, labour intensive and time consuming procedure. The article outlines a cost-effective, high throughput alternative to conventional fluorescence imaging techniques. With system level integration of custom-designed microfluidics and optics, we demonstrate fluorescence microscopy based imaging flow analyzer. Using this system we have imaged more than 2900 FITC labeled fluorescent beads per minute. This demonstrates high-throughput characteristics of our flow analyzer in comparison to conventional fluorescence microscopy. The issue of motion blur at high flow rates limits the achievable throughput in image based flow analyzers. Here we address the issue by computationally deblurring the images and show that this restores the morphological features otherwise affected by motion blur. By further optimizing concentration of the sample solution and flow speeds, along with imaging multiple channels simultaneously, the system is capable of providing throughput of about 480 beads per second.

  13. Extraction of skin-friction fields from surface flow visualizations as an inverse problem

    NASA Astrophysics Data System (ADS)

    Liu, Tianshu

    2013-12-01

    Extraction of high-resolution skin-friction fields from surface flow visualization images as an inverse problem is discussed from a unified perspective. The surface flow visualizations used in this study are luminescent oil-film visualization and heat-transfer and mass-transfer visualizations with temperature- and pressure-sensitive paints (TSPs and PSPs). The theoretical foundations of these global methods are the thin-oil-film equation and the limiting forms of the energy- and mass-transport equations at a wall, which are projected onto the image plane to provide the relationships between a skin-friction field and the relevant quantities measured by using an imaging system. Since these equations can be re-cast in the same mathematical form as the optical flow equation, they can be solved by using the variational method in the image plane to extract relative or normalized skin-friction fields from images. Furthermore, in terms of instrumentation, essentially the same imaging system for measurements of luminescence can be used in these surface flow visualizations. Examples are given to demonstrate the applications of these methods in global skin-friction diagnostics of complex flows.

  14. An artificial intelligence based improved classification of two-phase flow patterns with feature extracted from acquired images.

    PubMed

    Shanthi, C; Pappa, N

    2017-05-01

    Flow pattern recognition is necessary to select design equations for finding operating details of the process and to perform computational simulations. Visual image processing can be used to automate the interpretation of patterns in two-phase flow. In this paper, an attempt has been made to improve the classification accuracy of the flow pattern of gas/ liquid two- phase flow using fuzzy logic and Support Vector Machine (SVM) with Principal Component Analysis (PCA). The videos of six different types of flow patterns namely, annular flow, bubble flow, churn flow, plug flow, slug flow and stratified flow are recorded for a period and converted to 2D images for processing. The textural and shape features extracted using image processing are applied as inputs to various classification schemes namely fuzzy logic, SVM and SVM with PCA in order to identify the type of flow pattern. The results obtained are compared and it is observed that SVM with features reduced using PCA gives the better classification accuracy and computationally less intensive than other two existing schemes. This study results cover industrial application needs including oil and gas and any other gas-liquid two-phase flows. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  15. Family functioning in the families of psychiatric patients: a comparison with nonclinical families.

    PubMed

    Trangkasombat, Umaporn

    2006-11-01

    To examine family functioning in the families of psychiatric patients. Families of psychiatric patients and nonclinical families were compared. There were 60 families in each group. The instrument included a semistructured interview of family functioning and the Chulalongkorn Family Inventory (CFI), a self-report questionnaire designed to assess the perception of one's family. From the assessment by semistructured interview, 83.3% of psychiatric families and 45.0% of nonclinical families were found to be dysfunctional in at least one dimension. The difference was statistically significant (p < 0.001). The average number of dysfunctional dimensions in the psychiatric families was significantly higher than in the nonclinical control group, 3.5 +/- 1.9 and 0.98 +/- 1.5 respectively, p < 0.0001. The CFI scores of the psychiatric families were significantly lower than the control group, reflecting poor family functioning. The dysfunctions were mostly in the following dimensions: problem-solving, communication, affective responsiveness, affective involvement, and behavior control. Psychiatric families faced more psychosocial stressors and the average number of stressors was higher than the control families, 88.3% vs. 56.7% and 4.2 +/- 2.7 vs. 1.3 +/- 1.47 stressors respectively, p < 0.0001. Family functioning of psychiatric patients was less healthy than the nonclinical control. The present study underlined the significance of family assessment and family intervention in the comprehensive care of psychiatric patients.

  16. Meta-analysis comparing maintenance strategies with continuous therapy and complete chemotherapy-free interval strategies in the treatment of metastatic colorectal cancer

    PubMed Central

    Zhao, Lei; Wang, Jing; Li, Huihui; Che, Juanjuan; Cao, Bangwei

    2016-01-01

    There is as yet no consensus as to the best choice among the three treatment options (maintenance, complete chemotherapy-free intervals [CFIs], and continuous) for metastatic colorectal cancer (CRC). We performed a meta-analysis of six trials (N = 2, 454 patients) to compare the safety and efficacy of those three treatment strategies. Maintenance appeared to offer an advantage over CFI with respect to progression-free survival (PFS) (hazard ratio [HR]: 0.53, 95% confidence interval [CI], 0.40–0.69). PFS and overall survival (OS) were comparable between the maintenance and continuous strategies (HR: 1.18, 95% CI, 0.96–1.46; HR: 1.05, 95% CI, 0.98–1.27, respectively), as was OS between the maintenance and CFI strategies (HR: 0.84; 95% CI, 0.70–1.00). The incidence of grade 3/4 toxicity, including neutropenia, neuropathy, hand-foot syndrome and fatigue, was lower with maintenance than with continuous therapy. A maintenance regimen utilizing bevacizumab-based doublets appeared to confer a slight advantage over bevacizumab monotherapy with respect to PFS (P = 0.011). Maintenance appeared to reduce cumulative grade 3/4 toxicity as compared to the continuous strategy, while showing comparable efficacy. Bevacizumab-based doublets appeared to be of particular value in patients with metastatic CRC. PMID:27072579

  17. Modeling the Etiology of Adolescent Substance Use: A Test of the Social Development Model

    PubMed Central

    Catalano, Richard F.; Kosterman, Rick; Hawkins, J. David; Newcomb, Michael D.; Abbott, Robert D.

    2007-01-01

    The social development model is a general theory of human behavior that seeks to explain antisocial behaviors through specification of predictive developmental relationships. It incorporates the effects of empirical predictors (“risk factors” and “protective factors”) for antisocial behavior and attempts to synthesize the most strongly supported propositions of control theory, social learning theory, and differential association theory. This article examines the power of social development model constructs measured at ages 9 to 10 and 13 to 14 to predict drug use at ages 17 to 18. The sample of 590 is from the longitudinal panel of the Seattle Social Development Project, which in 1985 sampled fifth grade students from high crime neighborhoods in Seattle, Washington. Structural equation modeling techniques were used to examine the fit of the model to the data. Although all but one path coefficient were significant and in the expected direction, the model did not fit the data as well as expected (CFI=.87). We next specified second-order factors for each path to capture the substantial common variance in the constructs' opportunities, involvement, and rewards. This model fit the data well (CFI=.90). We conclude that the social development model provides an acceptable fit to predict drug use at ages 17 to 18. Implications for the temporal nature of key constructs and for prevention are discussed. PMID:17848978

  18. The impact of education, country, race and ethnicity on the self-report of postpartum depression using the Edinburgh Postnatal Depression Scale.

    PubMed

    Di Florio, A; Putnam, K; Altemus, M; Apter, G; Bergink, V; Bilszta, J; Brock, R; Buist, A; Deligiannidis, K M; Devouche, E; Epperson, C N; Guille, C; Kim, D; Lichtenstein, P; Magnusson, P K E; Martinez, P; Munk-Olsen, T; Newport, J; Payne, J; Penninx, B W; O'Hara, M; Robertson-Blackmore, E; Roza, S J; Sharkey, K M; Stuart, S; Tiemeier, H; Viktorin, A; Schmidt, P J; Sullivan, P F; Stowe, Z N; Wisner, K L; Jones, I; Rubinow, D R; Meltzer-Brody, S

    2017-04-01

    Universal screening for postpartum depression is recommended in many countries. Knowledge of whether the disclosure of depressive symptoms in the postpartum period differs across cultures could improve detection and provide new insights into the pathogenesis. Moreover, it is a necessary step to evaluate the universal use of screening instruments in research and clinical practice. In the current study we sought to assess whether the Edinburgh Postnatal Depression Scale (EPDS), the most widely used screening tool for postpartum depression, measures the same underlying construct across cultural groups in a large international dataset. Ordinal regression and measurement invariance were used to explore the association between culture, operationalized as education, ethnicity/race and continent, and endorsement of depressive symptoms using the EPDS on 8209 new mothers from Europe and the USA. Education, but not ethnicity/race, influenced the reporting of postpartum depression [difference between robust comparative fit indexes (∆*CFI) 0.01), but not between European countries (∆*CFI < 0.01). Investigators and clinicians should be aware of the potential differences in expression of phenotype of postpartum depression that women of different educational backgrounds may manifest. The increasing cultural heterogeneity of societies together with the tendency towards globalization requires a culturally sensitive approach to patients, research and policies, that takes into account, beyond rhetoric, the context of a person's experiences and the context in which the research is conducted.

  19. Validation of the Social Provisions Scale in people with multiple sclerosis.

    PubMed

    Chiu, Chung-Yi; Motl, Robert W; Ditchman, Nicole

    2016-08-01

    This study examined the factorial and construct validity of the Social Provisions Scale (SPS) in a sample of people with multiple sclerosis (MS). Participants included 292 individuals with MS (83.9% women) recruited from the Greater Illinois, Gateway, and Indiana chapters of the National Multiple Sclerosis Society. Participants completed the SPS and pain, fatigue, depression, anxiety, MS self-efficacy, quality of life, and satisfaction with life measures. Factorial validity was tested using confirmatory factor analysis (CFA), and construct validity was examined based on the strength of bivariate correlations with scores on related measures. Findings from the CFA indicated that a first-order, 6-factor measurement model provided a good fit for the 24 items of the SPS (CFI = .94, TLI = .93, RMSEA = 0.07) and that the 6 factors could be described by a single, second-order factor of the overall social provisions (CFI = .93, TLI = .92, RMSEA = 0.08). Cronbach's alpha was .89 for the global score and between .66 and .81 for the 6 subscales. The SPS global and subscale scores correlated significantly with satisfaction with life, depression, anxiety, MS self-efficacy, and quality of life measures. Findings from this study support the factorial validity, construct validity, and reliability of the SPS as a measure of social provisions for use with people with MS. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  20. [Aging and spirituality: Factorial structure and reliability of 2 scales].

    PubMed

    Galiana, Laura; Sancho, Patricia; Oliver, Amparo; Tomás, José Manuel; Calatayud, Pablo

    2016-01-01

    In the field of gerontology, the study of the improvement of health and quality of life, and «successfully aging», spirituality plays a key role and, is one of the current research approaches. However, its incorporation into scientific literature is arduous and slow, a fact that is in part due to the absence of developed and validated measurement tools, particularly, in the Spanish speaking area. This work aims to present evidence of the psychometric properties of two tools for the measurement of spirituality: the Functional Assessment of Chronic Illness Therapy Spiritual Well-Being (FACIT-Sp) and the GES Questionnaire. A sample of 224 elderly persons from Valencia (Spain) was recruited, on which two confirmatory factor analyses were estimated, with the proposed a priori structures for each tool, together with several reliability coefficients. Both models presented an good fit to the data: χ(2)51=104.97 (P<.01); CFI=.973; RMSEA=.076 for the FACIT-Sp, and χ(2)17=31.76 (P>.05); CFI=.996; RMSEA=.050 for the GES Questionnaire. Reliability indices also supported the use of the scales in elderly population, with alphas of .85 and .86, respectively. These results may be useful as a starting point to include spirituality in works that aim to discover the mechanisms involved in successful aging. Copyright © 2016 SEGG. Publicado por Elsevier España, S.L.U. All rights reserved.

  1. [VALIDATION OF THE HUNGARIAN UNIFIED DYSKINESIA RATING SCALE].

    PubMed

    Horváth, Krisztina; Aschermann, Zsuzsanna; Ács, Péter; Bosnyák, Edit; Deli, Gabriella; Pál, Endre; Késmárki, Ildiko; Horvath, Réka; Takacs, Katalin; Balázs, Eva; Komoly, Sámuel; Bokor, Magdolna; Rigó, Eszter; Lajtos, Júlia; Takáts, Annamária; Tóth, Adrián; Klivényi, Péter; Dibó, György; Vecsei, László; Hidasi, Eszter; Nagy, Ferenc; Herceg, Mihály; Imre, Piroska; Kovács, Norbert

    2015-05-30

    The Unified Dyskinesia Rating Scale (UDysRS) was published in 2008. It was designed to be simultaneous valid, reliable and sensitive to therapeutic changes. The Movement Disorder Society organizing team developed guidelines for the development of official non-English translations consisting of four steps: translation/back-translation, cognitive pretesting, large field testing, and clinimetric analysis. The aim of this paper was to introduce the new UDysRS and its validation process into Hungarian. After the translation of UDysRS into Hungarian and back-translated into English, it was reviewed by the UDysRS translation administration team. Subsequent cognitive pretesting was conducted with ten patients. For the large field testing phase, the Hungarian official working draft version of UDysRS was tested with 256 patients with Parkinson's disease having dyskinesia. Confirmatory factor analyses (CFA) determined whether the factor structure for the valid Spanish UDysRS could be confirmed in data collected using the Hungarian Official Draft Version. To become an official translation, the Comparative Fit Index (CFI) had to be ≥ 0.90 compared to the Spanish-language version. For the Hungarian UDysRS the CFI was 0.98. The overall factor structure of the Hungarian version was consistent with that of the Spanish version based on the high CFIs for the UDysRS in the CFA; therefore, this version was designated as the Official Hungarian Version Of The UDysRS.

  2. How can Academic Context Variables Contribute to the Personal Well-Being of Higher Education Students?

    PubMed

    Figueira, Célia Palma; Marques-Pinto, Alexandra; Pereira, Cicero Roberto; Roberto, Magda Sofia

    2017-10-11

    This study analyzed the influence of perceived time pressure, role clarity, working conditions and peer social support on the personal well-being (subjective, psychological and social well-being) of higher education students, in a sample of 128 Portuguese students from the University of Lisbon. A model was proposed which predicts a negative influence of time pressure and a positive influence of role clarity, working conditions and peer social support on students' personal well-being, throughout the academic year. Data was collected by means of a longitudinal design, at the beginning and end of the academic year, through self-report questionnaires. Structural equation models were used to analyze cross-sectional and cross-lagged relations among the variables. At cross-sectional level, results revealed a good fit to data (CFI = .928; IFI = .931; RMSEA = .060) illustrating that the perception of academic context variables was related to well-being dimensions. At longitudinal level, however, cross-lagged models did not fit so well to the data (CFI = .863; IFI = .869; RMSEA = .058) with both perceptions of time pressure (β = .167; p = .037) and role clarity (β = -.288; p = .031) significantly predicting well-being, but not in the expected direction, encouraging the accomplishment of studies to further a broader understanding of higher education students' well-being and its predictors. Implications for higher education scholars and practitioners and suggestions for future research are discussed.

  3. Thermal imaging for cold air flow visualisation and analysis

    NASA Astrophysics Data System (ADS)

    Grudzielanek, M.; Pflitsch, A.; Cermak, J.

    2012-04-01

    In this work we present first applications of a thermal imaging system for animated visualization and analysis of cold air flow in field studies. The development of mobile thermal imaging systems advanced very fast in the last decades. The surface temperature of objects, which is detected with long-wave infrared radiation, affords conclusions in different problems of research. Modern thermal imaging systems allow infrared picture-sequences and a following data analysis; the systems are not exclusive imaging methods like in the past. Thus, the monitoring and analysing of dynamic processes became possible. We measured the cold air flow on a sloping grassland area with standard methods (sonic anemometers and temperature loggers) plus a thermal imaging system measuring in the range from 7.5 to 14µm. To analyse the cold air with the thermal measurements, we collected the surface infrared temperatures at a projection screen, which was located in cold air flow direction, opposite the infrared (IR) camera. The intention of using a thermal imaging system for our work was: 1. to get a general idea of practicability in our problem, 2. to assess the value of the extensive and more detailed data sets and 3. to optimise visualisation. The results were very promising. Through the possibility of generating time-lapse movies of the image sequences in time scaling, processes of cold air flow, like flow waves, turbulence and general flow speed, can be directly identified. Vertical temperature gradients and near-ground inversions can be visualised very well. Time-lapse movies will be presented. The extensive data collection permits a higher spatial resolution of the data than standard methods, so that cold air flow attributes can be explored in much more detail. Time series are extracted from the IR data series, analysed statistically, and compared to data obtained using traditional systems. Finally, we assess the usefulness of the additional measurement of cold air flow with thermal imaging systems.

  4. Ultrahigh sensitive optical microangiography for in vivo imaging of microcirculations within human skin tissue beds

    PubMed Central

    An, Lin; Qin, Jia; Wang, Ruikang K

    2010-01-01

    In this paper, we demonstrate for the first time that the detailed cutaneous blood flow at capillary level within dermis of human skin can be imaged by optical micro-angiography (OMAG) technique. A novel scanning protocol, i.e. fast B scan mode is used to achieve the capillary flow imaging. We employ a 1310nm system to scan the skin tissue at an imaging rate of 300 frames per second, which requires only ∼5 sec to complete one 3D imaging of capillary blood flow within skin. The technique is sensitive enough to image the very slow blood flows at ∼4 μm/sec. The promising results show a great potential of OMAG's role in the diagnosis, treatment and management of human skin diseases. PMID:20588668

  5. Using artificial intelligence to improve identification of nanofluid gas-liquid two-phase flow pattern in mini-channel

    NASA Astrophysics Data System (ADS)

    Xiao, Jian; Luo, Xiaoping; Feng, Zhenfei; Zhang, Jinxin

    2018-01-01

    This work combines fuzzy logic and a support vector machine (SVM) with a principal component analysis (PCA) to create an artificial-intelligence system that identifies nanofluid gas-liquid two-phase flow states in a vertical mini-channel. Flow-pattern recognition requires finding the operational details of the process and doing computer simulations and image processing can be used to automate the description of flow patterns in nanofluid gas-liquid two-phase flow. This work uses fuzzy logic and a SVM with PCA to improve the accuracy with which the flow pattern of a nanofluid gas-liquid two-phase flow is identified. To acquire images of nanofluid gas-liquid two-phase flow patterns of flow boiling, a high-speed digital camera was used to record four different types of flow-pattern images, namely annular flow, bubbly flow, churn flow, and slug flow. The textural features extracted by processing the images of nanofluid gas-liquid two-phase flow patterns are used as inputs to various identification schemes such as fuzzy logic, SVM, and SVM with PCA to identify the type of flow pattern. The results indicate that the SVM with reduced characteristics of PCA provides the best identification accuracy and requires less calculation time than the other two schemes. The data reported herein should be very useful for the design and operation of industrial applications.

  6. An investigation into the blood-flow characteristics of telangiectatic skin lesions in systemic sclerosis using dual-wavelength laser Doppler imaging.

    PubMed

    Murray, A K; Moore, T L; Griffiths, C E M; Herrick, A L

    2009-07-01

    Superficial telangiectases associated with systemic sclerosis may be more responsive to treatment than those deeper in the dermis. We investigated whether dual-wavelength laser Doppler imaging (LDI) is sufficiently sensitive to ascertain the distribution of blood flow within telangiectases and whether blood flow relates to telangiectatic diameter. The perfusion and diameter of 20 telangiectases were measured in superficial and deeper layers of the skin using dual-wavelength LDI. Of 20 telangiectases, 18 had higher blood flow in the red (representing deeper blood flow), rather than the green (representing superficial blood flow) wavelength images. Clinically apparent diameters correlated with those of the superficial (r = 0.61, P = 0.01), but not with the deeper blood flow images. Hence, the apparent size of telangiectases at the skin surface does not predict blood flow through the microvessel(s) at deeper levels, and thus clinically apparent size is unlikely to predict treatment response. Dual-wavelength LDI may help predict treatment response.

  7. B-Flow Imaging in Lower Limb Peripheral Arterial Disease and Bypass Graft Ultrasonography.

    PubMed

    D'Abate, Fabrizio; Ramachandran, Veni; Young, Mark A; Farrah, John; Ahmed, Mudasar H; Jones, Keith; Hinchliffe, Robert J

    2016-09-01

    Doppler ultrasonography plays a key role in the diagnosis of peripheral arterial disease, but is often limited by pitfalls that may be overcome by B-flow imaging. Thus far, there is little information on B-flow imaging for the assessment of peripheral arterial disease and bypass grafts in lower limbs. This article describes the authors' early experience with B-flow in the lower extremities. Sixty patients were included among a large cohort of patients routinely referred to the vascular laboratory for peripheral arterial disease and bypass graft assessments. Two experienced vascular sonographers performed all scans, comparing color Doppler ultrasonography with B-flow imaging. All scans were performed using a combination of the 9 L linear and C2-9 curvilinear transducers with the LOGIQ E9 system (GE Healthcare, Waukesha, WI, USA). Our experience indicates that this relatively unexplored technology has the potential to significantly improve peripheral blood flow evaluation. Nevertheless, B-flow imaging is not exempt from limitations and should be considered complementary to color Doppler ultrasonography. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  8. Management of Low-Flow Vascular Malformations: Clinical Presentation, Classification, Patient Selection, Imaging and Treatment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCafferty, Ian, E-mail: ian.mccafferty@uhb.nhs.uk

    This review article aims to give an overview of the current state of imaging, patient selection, agents and techniques used in the management of low-flow vascular malformations. The review includes the current classifications for low-flow vascular malformations including the 2014 updates. Clinical presentation and assessment is covered with a detailed section on the common sclerosant agents used to treat low-flow vascular malformations, including dosing and common complications. Imaging is described with a guide to a simple stratification of the use of imaging for diagnosis and interventional techniques.

  9. Label-Free, Flow-Imaging Methods for Determination of Cell Concentration and Viability.

    PubMed

    Sediq, A S; Klem, R; Nejadnik, M R; Meij, P; Jiskoot, Wim

    2018-05-30

    To investigate the potential of two flow imaging microscopy (FIM) techniques (Micro-Flow Imaging (MFI) and FlowCAM) to determine total cell concentration and cell viability. B-lineage acute lymphoblastic leukemia (B-ALL) cells of 2 different donors were exposed to ambient conditions. Samples were taken at different days and measured with MFI, FlowCAM, hemocytometry and automated cell counting. Dead and live cells from a fresh B-ALL cell suspension were fractionated by flow cytometry in order to derive software filters based on morphological parameters of separate cell populations with MFI and FlowCAM. The filter sets were used to assess cell viability in the measured samples. All techniques gave fairly similar cell concentration values over the whole incubation period. MFI showed to be superior with respect to precision, whereas FlowCAM provided particle images with a higher resolution. Moreover, both FIM methods were able to provide similar results for cell viability as the conventional methods (hemocytometry and automated cell counting). FIM-based methods may be advantageous over conventional cell methods for determining total cell concentration and cell viability, as FIM measures much larger sample volumes, does not require labeling, is less laborious and provides images of individual cells.

  10. Visualization of Pulmonary Clearance Mechanisms via Noninvasive Optical Imaging Validated by Near-Infrared Flow Cytometry

    PubMed Central

    Zhou, Haiying; Gunsten, Sean P.; Zhegalova, Natalia G.; Bloch, Sharon; Achilefu, Samuel; Holley, J. Christopher; Schweppe, Daniel; Akers, Walter; Brody, Steven L.; Eades, William; Berezin, Mikhail Y.

    2016-01-01

    In vivo optical imaging with near-infrared (NIR) probes is an established method of diagnostics in preclinical and clinical studies. However, the specificities of these probes are difficult to validate ex vivo due to the lack of NIR flow cytometry. To address this limitation, we modified a flow cytometer to include an additional NIR channel using a 752 nm laser line. The flow cytometry system was tested using NIR microspheres and cell lines labeled with a combination of visible range and NIR fluorescent dyes. The approach was verified in vivo in mice evaluated for immune response in lungs after intratracheal delivery of the NIR contrast agent. Flow cytometry of cells obtained from the lung bronchoalveolar lavage demonstrated that the NIR dye was taken up by pulmonary macrophages as early as four-hours post-injection. This combination of optical imaging with NIR flow cytometry extends the capability of imaging and enables complementation of in vivo imaging with cell-specific studies. PMID:25808737

  11. Label-free in vivo optical micro-angiography imaging of cerebral capillary blood flow within meninges and cortex in mice with the skull left intact

    NASA Astrophysics Data System (ADS)

    Jia, Yali; Wang, Ruikang K.

    2011-03-01

    Abnormal microcirculation within meninges is common in many neurological diseases. There is a need for an imaging method that is capable of visualizing functional meningeal microcirculations alone, preferably decoupled from the cortical blood flow. Optical microangiography (OMAG) is a recently developed label-free imaging method capable of producing 3D images of dynamic blood perfusion within micro-circulatory tissue beds at an imaging depth up to ~2 mm, with an unprecedented imaging sensitivity to the blood flow at ~4 μm/s. In this study, we demonstrate the utility of ultra-high sensitive OMAG in imaging the detailed blood flow distributions, at a capillary level resolution, within meninges and cortex in mice with the cranium left intact. The results indicate that OMAG can be a valuable tool for the study of meningeal circulations.

  12. Counter-streaming flows in a giant quiet-Sun filament observed in the extreme ultraviolet

    NASA Astrophysics Data System (ADS)

    Diercke, A.; Kuckein, C.; Verma, M.; Denker, C.

    2018-03-01

    Aim. The giant solar filament was visible on the solar surface from 2011 November 8-23. Multiwavelength data from the Solar Dynamics Observatory (SDO) were used to examine counter-streaming flows within the spine of the filament. Methods: We use data from two SDO instruments, the Atmospheric Imaging Assembly (AIA) and the Helioseismic and Magnetic Imager (HMI), covering the whole filament, which stretched over more than half a solar diameter. Hα images from the Kanzelhöhe Solar Observatory (KSO) provide context information of where the spine of the filament is defined and the barbs are located. We apply local correlation tracking (LCT) to a two-hour time series on 2011 November 16 of the AIA images to derive horizontal flow velocities of the filament. To enhance the contrast of the AIA images, noise adaptive fuzzy equalization (NAFE) is employed, which allows us to identify and quantify counter-streaming flows in the filament. We observe the same cool filament plasma in absorption in both Hα and EUV images. Hence, the counter-streaming flows are directly related to this filament material in the spine. In addition, we use directional flow maps to highlight the counter-streaming flows. Results: We detect counter-streaming flows in the filament, which are visible in the time-lapse movies in all four examined AIA wavelength bands (λ171 Å, λ193 Å, λ304 Å, and λ211 Å). In the time-lapse movies we see that these persistent flows lasted for at least two hours, although they became less prominent towards the end of the time series. Furthermore, by applying LCT to the images we clearly determine counter-streaming flows in time series of λ171 Å and λ193 Å images. In the λ304 Å wavelength band, we only see minor indications for counter-streaming flows with LCT, while in the λ211 Å wavelength band the counter-streaming flows are not detectable with this method. The diverse morphology of the filament in Hα and EUV images is caused by different absorption processes, i.e., spectral line absorption and absorption by hydrogen and helium continua, respectively. The horizontal flows reach mean flow speeds of about 0.5 km s-1 for all wavelength bands. The highest horizontal flow speeds are identified in the λ171 Å band with flow speeds of up to 2.5 km s-1. The results are averaged over a time series of 90 minutes. Because the LCT sampling window has finite width, a spatial degradation cannot be avoided leading to lower estimates of the flow velocities as compared to feature tracking or Doppler measurements. The counter-streaming flows cover about 15-20% of the whole area of the EUV filament channel and are located in the central part of the spine. Conclusions: Compared to the ground-based observations, the absence of seeing effects in AIA observations reveal counter-streaming flows in the filament even with a moderate image scale of 0. ''6 pixel-1. Using a contrast enhancement technique, these flows can be detected and quantified with LCT in different wavelengths. We confirm the omnipresence of counter-streaming flows also in giant quiet-Sun filaments. A movie associated to Fig. 6 is available at http://https://www.aanda.org

  13. Computation of fluid and particle motion from a time-sequenced image pair: a global outlier identification approach.

    PubMed

    Ray, Nilanjan

    2011-10-01

    Fluid motion estimation from time-sequenced images is a significant image analysis task. Its application is widespread in experimental fluidics research and many related areas like biomedical engineering and atmospheric sciences. In this paper, we present a novel flow computation framework to estimate the flow velocity vectors from two consecutive image frames. In an energy minimization-based flow computation, we propose a novel data fidelity term, which: 1) can accommodate various measures, such as cross-correlation or sum of absolute or squared differences of pixel intensities between image patches; 2) has a global mechanism to control the adverse effect of outliers arising out of motion discontinuities, proximity of image borders; and 3) can go hand-in-hand with various spatial smoothness terms. Further, the proposed data term and related regularization schemes are both applicable to dense and sparse flow vector estimations. We validate these claims by numerical experiments on benchmark flow data sets. © 2011 IEEE

  14. Transthoracic Ultrafast Doppler Imaging of Human Left Ventricular Hemodynamic Function

    PubMed Central

    Osmanski, Bruno-Félix; Maresca, David; Messas, Emmanuel; Tanter, Mickael; Pernot, Mathieu

    2016-01-01

    Heart diseases can affect intraventricular blood flow patterns. Real-time imaging of blood flow patterns is challenging because it requires both a high frame rate and a large field of view. To date, standard Doppler techniques can only perform blood flow estimation with high temporal resolution within small regions of interest. In this work, we used ultrafast imaging to map in 2D human left ventricular blood flow patterns during the whole cardiac cycle. Cylindrical waves were transmitted at 4800 Hz with a transthoracic phased array probe to achieve ultrafast Doppler imaging of the left ventricle. The high spatio-temporal sampling of ultrafast imaging permits to rely on a much more effective wall filtering and to increase sensitivity when mapping blood flow patterns during the pre-ejection, ejection, early diastole, diastasis and late diastole phases of the heart cycle. The superior sensitivity and temporal resolution of ultrafast Doppler imaging makes it a promising tool for the noninvasive study of intraventricular hemodynamic function. PMID:25073134

  15. A Mobile System for Measuring Water Surface Velocities Using Unmanned Aerial Vehicle and Large-Scale Particle Image Velocimetry

    NASA Astrophysics Data System (ADS)

    Chen, Y. L.

    2015-12-01

    Measurement technologies for velocity of river flow are divided into intrusive and nonintrusive methods. Intrusive method requires infield operations. The measuring process of intrusive methods are time consuming, and likely to cause damages of operator and instrument. Nonintrusive methods require fewer operators and can reduce instrument damages from directly attaching to the flow. Nonintrusive measurements may use radar or image velocimetry to measure the velocities at the surface of water flow. The image velocimetry, such as large scale particle image velocimetry (LSPIV) accesses not only the point velocity but the flow velocities in an area simultaneously. Flow properties of an area hold the promise of providing spatially information of flow fields. This study attempts to construct a mobile system UAV-LSPIV by using an unmanned aerial vehicle (UAV) with LSPIV to measure flows in fields. The mobile system consists of a six-rotor UAV helicopter, a Sony nex5T camera, a gimbal, an image transfer device, a ground station and a remote control device. The activate gimbal helps maintain the camera lens orthogonal to the water surface and reduce the extent of images being distorted. The image transfer device can monitor the captured image instantly. The operator controls the UAV by remote control device through ground station and can achieve the flying data such as flying height and GPS coordinate of UAV. The mobile system was then applied to field experiments. The deviation of velocities measured by UAV-LSPIV of field experiments and handhold Acoustic Doppler Velocimeter (ADV) is under 8%. The results of the field experiments suggests that the application of UAV-LSPIV can be effectively applied to surface flow studies.

  16. Perfusion flow bioreactor for 3D in situ imaging: investigating cell/biomaterials interactions.

    PubMed

    Stephens, J S; Cooper, J A; Phelan, F R; Dunkers, J P

    2007-07-01

    The capability to image real time cell/material interactions in a three-dimensional (3D) culture environment will aid in the advancement of tissue engineering. This paper describes a perfusion flow bioreactor designed to hold tissue engineering scaffolds and allow for in situ imaging using an upright microscope. The bioreactor can hold a scaffold of desirable thickness for implantation (>2 mm). Coupling 3D culture and perfusion flow leads to the creation of a more biomimetic environment. We examined the ability of the bioreactor to maintain cell viability outside of an incubator environment (temperature and pH stability), investigated the flow features of the system (flow induced shear stress), and determined the image quality in order to perform time-lapsed imaging of two-dimensional (2D) and 3D cell culture. In situ imaging was performed on 2D and 3D, culture samples and cell viability was measured under perfusion flow (2.5 mL/min, 0.016 Pa). The visualization of cell response to their environment, in real time, will help to further elucidate the influences of biomaterial surface features, scaffold architectures, and the influence of flow induced shear on cell response and growth of new tissue. (c) 2006 Wiley Periodicals, Inc.

  17. MR imaging of apparent 3He gas transport in narrow pipes and rodent airways

    NASA Astrophysics Data System (ADS)

    Minard, Kevin R.; Jacob, Richard E.; Laicher, Gernot; Einstein, Daniel R.; Kuprat, Andrew P.; Corley, Richard A.

    2008-10-01

    High sensitivity makes hyperpolarized 3He an attractive signal source for visualizing gas flow with magnetic resonance (MR) imaging. Its rapid Brownian motion, however, can blur observed flow lamina and alter measured diffusion rates when excited nuclei traverse shear-induced velocity gradients during data acquisition. Here, both effects are described analytically, and predicted values for measured transport during laminar flow through a straight, 3.2-mm diameter pipe are validated using two-dimensional (2D) constant-time images of different binary gas mixtures. Results show explicitly how measured transport in narrow conduits is characterized by apparent values that depend on underlying gas dynamics and imaging time. In ventilated rats, this is found to obscure acquired airflow images. Nevertheless, flow splitting at airway branches is still evident and use of 3D vector flow mapping is shown to reveal surprising detail that highlights the correlation between gas dynamics and lung structure.

  18. Dust Mantle Near Pavonis Mons

    NASA Technical Reports Server (NTRS)

    2003-01-01

    MGS MOC Release No. MOC2-356, 10 May 2003

    This Mars Global Surveyor (MGS) Mars Orbiter Camera (MOC) image shows a thick mantle of dust covering lava flows north of Pavonis Mons so well that the flows are no longer visible. Flows are known to occur here because of the proximity to the volcano, and such flows normally have a very rugged surface. Fine dust, however, has settled out of the atmosphere over time and obscured the flows from view. The cliff at the top of the image faces north (up), the cliff in the middle of the image faces south (down), and the rugged slope at the bottom of the image faces north (up). The dark streak at the center-left was probably caused by an avalanche of dust sometime in the past few decades. The image is located near 4.1oN, 111.3oW. Sunlight illuminates the scene from the right/lower right.

  19. Flow measurements in sewers based on image analysis: automatic flow velocity algorithm.

    PubMed

    Jeanbourquin, D; Sage, D; Nguyen, L; Schaeli, B; Kayal, S; Barry, D A; Rossi, L

    2011-01-01

    Discharges of combined sewer overflows (CSOs) and stormwater are recognized as an important source of environmental contamination. However, the harsh sewer environment and particular hydraulic conditions during rain events reduce the reliability of traditional flow measurement probes. An in situ system for sewer water flow monitoring based on video images was evaluated. Algorithms to determine water velocities were developed based on image-processing techniques. The image-based water velocity algorithm identifies surface features and measures their positions with respect to real world coordinates. A web-based user interface and a three-tier system architecture enable remote configuration of the cameras and the image-processing algorithms in order to calculate automatically flow velocity on-line. Results of investigations conducted in a CSO are presented. The system was found to measure reliably water velocities, thereby providing the means to understand particular hydraulic behaviors.

  20. Integrated light-sheet imaging and flow-based enquiry (iLIFE) system for 3D in-vivo imaging of multicellular organism

    NASA Astrophysics Data System (ADS)

    Rasmi, Chelur K.; Padmanabhan, Sreedevi; Shirlekar, Kalyanee; Rajan, Kanhirodan; Manjithaya, Ravi; Singh, Varsha; Mondal, Partha Pratim

    2017-12-01

    We propose and demonstrate a light-sheet-based 3D interrogation system on a microfluidic platform for screening biological specimens during flow. To achieve this, a diffraction-limited light-sheet (with a large field-of-view) is employed to optically section the specimens flowing through the microfluidic channel. This necessitates optimization of the parameters for the illumination sub-system (illumination intensity, light-sheet width, and thickness), microfluidic specimen platform (channel-width and flow-rate), and detection sub-system (camera exposure time and frame rate). Once optimized, these parameters facilitate cross-sectional imaging and 3D reconstruction of biological specimens. The proposed integrated light-sheet imaging and flow-based enquiry (iLIFE) imaging technique enables single-shot sectional imaging of a range of specimens of varying dimensions, ranging from a single cell (HeLa cell) to a multicellular organism (C. elegans). 3D reconstruction of the entire C. elegans is achieved in real-time and with an exposure time of few hundred micro-seconds. A maximum likelihood technique is developed and optimized for the iLIFE imaging system. We observed an intracellular resolution for mitochondria-labeled HeLa cells, which demonstrates the dynamic resolution of the iLIFE system. The proposed technique is a step towards achieving flow-based 3D imaging. We expect potential applications in diverse fields such as structural biology and biophysics.

  1. Remote sensing data of SP Mountain and SP Lava flow in North-Central Arizona

    USGS Publications Warehouse

    Schaber, G.G.; Elachi, C.; Farr, T.G.

    1980-01-01

    Multifrequency airborne radar image data of SP Mountain [Official name of feature (U.S. Geological Survey, 1970)] and SP flow (and vicinity) in north-central Arizona were obtained in diverse viewing directions and direct and cross-polarization, then compared with surface and aerial photography, LANDSAT multispectral scanner data, airborne thermal infrared imagery, surface geology, and surface roughness statistics. The extremely blocky, basaltic andesite of SP flow is significantly brighter on direct-polarization K-band (0.9-cm wavelength) images than on cross-polarized images taken simultaneously. Conversely, for the longer wavelength (25 cm) L-band radar images, the cross-polarization image returns from SP flow are brighter than the direct-polarized image. This effect is explained by multiple scattering and the strong wavelength dependence of polarization effects caused by the rectilinear basaltic andesite scatters. Two distinct types of surface relief on SP flow, one extremely blocky, the other subdued, are found to be clearly discriminated on the visible and thermal wavelength images but are separable only on the longer wavelength L-band radar image data. The inability of the K- and X- (3-cm wavelength) band radars to portray the differences in roughness between the two SP flow surface units is attributed to the radar frequency dependence of the surface-relief scale, which, described as the Rayleigh criterion, represents the transition between quasispecular and primarily diffuse backscatter. ?? 1980.

  2. Flow Microscopy Imaging Is Sensitive to Characteristics of Subvisible Particles in Peginesatide Formulations Associated With Severe Adverse Reactions.

    PubMed

    Daniels, Austin L; Randolph, Theodore W

    2018-05-01

    The presence of subvisible particles in formulations of therapeutic proteins is a risk factor for adverse immune responses. Although the immunogenic potential of particulate contaminants likely depends on particle structural characteristics (e.g., composition, size, and shape), exact structure-immunogenicity relationships are unknown. Images recorded by flow imaging microscopy reflect information about particle morphology, but flow microscopy is typically used to determine only particle size distributions, neglecting information on particle morphological features that may be immunologically relevant. We recently developed computational techniques that utilize the Kullback-Leibler divergence and multidimensional scaling to compare the morphological properties of particles in sets of flow microscopy images. In the current work, we combined these techniques with expectation maximization cluster analyses and used them to compare flow imaging microscopy data sets that had been collected by the U.S. Food and Drug Administration after severe adverse drug reactions (including 7 fatalities) were observed in patients who had been administered some lots of peginesatide formulations. Flow microscopy images of particle populations found in the peginesatide lots associated with severe adverse reactions in patients were readily distinguishable from images of particles in lots where severe adverse reactions did not occur. Copyright © 2018 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  3. Using Google Earth To Interpret The Southern Taiwan Hsiaolin Village Catastrophe

    NASA Astrophysics Data System (ADS)

    Lin, Y. H.; Huang, C. M.; Keck, J.; Wei, L. W.; Pan, K. L.

    2012-04-01

    The August, 2009 Typhoon Morakot resulted in accumulated rainfalls exceeding 2000 mm and the triggering of a massive debris flow that buried Hsiaolin village. Hundreds of people were killed and both domestic and international natural disaster prevention agencies took note of this large scale disaster that was not prevented. Interpretation of Google Earth satellite images reveals that the Hsiaolin debris flow originated in a single location and then split into two parts. The northern debris flow, the smaller of the two parts, flowed within a ravine. The southern part of the debris flow, much larger than the northern part, was responsible for the burial of Hsiaolin village. The movement of the debris flow can be divided into three processes. First a slope failure and subsequent debris flow occurred within a curved ravine. Second, the debris flow eroded the bank of the ravine laterally, causing translational failure of the ravine walls. A massive debris flow, made up of a combination of materials from both the original debris flow and the ravine walls, jammed within the ravine. Finally, as a result of the jam, the debris flow was redirected towards Hsiaolin village. Overlaying locations of the post-Hsiaolin debris flow landforms on top of pre-failure satellite images reveals that characteristics of the post failure landforms match perfectly with characteristics observed in the pre-failure satellite images. This finding supports the thought that large scale geologic disasters are reoccurring. This finding also suggests that areas near villages can use simple satellite image analysis to rapidly identify ancient landslides and that such information may help early evacuation planning. With such planning, property and life losses due to natural disasters can be reduced. Key word: Hsiaolin Village, Debris Flow, Remote Sensing, Image Interpretation, Cause of Disaster, Disaster Recovery, Deep-Seated Landslide, Ancient Debris Flow

  4. Measurement of viscous flow velocity and flow visualization using two magnetic resonance imagers

    NASA Astrophysics Data System (ADS)

    Boiko, A. V.; Akulov, A. E.; Chupakhin, A. P.; Cherevko, A. A.; Denisenko, N. S.; Savelov, A. A.; Stankevich, Yu. A.; Khe, A. K.; Yanchenko, A. A.; Tulupov, A. A.

    2017-03-01

    The accuracies of measuring the velocity field using clinical and research magnetic resonance imagers are compared. The flow velocity of a fluid simulating blood in a carotid artery model connected to a programmable pump was measured. Using phase-contrast magnetic resonance tomography, the velocity distributions in the carotid artery model were obtained and compared with the analytical solution for viscous liquid flow in a cylindrical tube (Poiseuille flow). It is found that the accuracy of the velocity measurement does not depend on the field induction and spatial resolution of the imagers.

  5. Injectant mole-fraction imaging in compressible mixing flows using planar laser-induced iodine fluorescence

    NASA Technical Reports Server (NTRS)

    Hartfield, Roy J., Jr.; Abbitt, John D., III; Mcdaniel, James C.

    1989-01-01

    A technique is described for imaging the injectant mole-fraction distribution in nonreacting compressible mixing flow fields. Planar fluorescence from iodine, seeded into air, is induced by a broadband argon-ion laser and collected using an intensified charge-injection-device array camera. The technique eliminates the thermodynamic dependence of the iodine fluorescence in the compressible flow field by taking the ratio of two images collected with identical thermodynamic flow conditions but different iodine seeding conditions.

  6. High quality optical microangiography of ocular microcirculation and measurement of total retinal blood flow in mouse eye

    NASA Astrophysics Data System (ADS)

    Zhi, Zhongwei; Yin, Xin; Dziennis, Suzan; Alpers, Charles E.; Wang, Ruikang K.

    2013-03-01

    Visualization and measurement of retinal blood flow (RBF) is important to the diagnosis and management of different eye diseases, including diabetic retinopathy. Optical microangiography (OMAG) is developed for generating 3D dynamic microcirculation image and later refined into ultra-high sensitive OMAG (UHS-OMAG) for true capillary vessels imaging. Here, we present the application of OMAG imaging technique for visualization of depth-resolved vascular network within retina and choroid as well as measurement of total retinal blood flow in mice. A fast speed spectral domain OCT imaging system at 820nm with a line scan rate of 140 kHz was developed to image mouse posterior eye. By applying UHS-OMAG scanning protocol and processing algorithm, we achieved true capillary level imaging of retina and choroid vasculature in mouse eye. The vascular pattern within different retinal layers and choroid was presented. An en face Doppler OCT approach [1] without knowing Doppler angle was adopted for the measurement of total retinal blood flow. The axial blood flow velocity is measured in an en face plane by raster scanning and the flow is calculated by integrating over the vessel area of the central retinal artery.

  7. Least Median of Squares Filtering of Locally Optimal Point Matches for Compressible Flow Image Registration

    PubMed Central

    Castillo, Edward; Castillo, Richard; White, Benjamin; Rojo, Javier; Guerrero, Thomas

    2012-01-01

    Compressible flow based image registration operates under the assumption that the mass of the imaged material is conserved from one image to the next. Depending on how the mass conservation assumption is modeled, the performance of existing compressible flow methods is limited by factors such as image quality, noise, large magnitude voxel displacements, and computational requirements. The Least Median of Squares Filtered Compressible Flow (LFC) method introduced here is based on a localized, nonlinear least squares, compressible flow model that describes the displacement of a single voxel that lends itself to a simple grid search (block matching) optimization strategy. Spatially inaccurate grid search point matches, corresponding to erroneous local minimizers of the nonlinear compressible flow model, are removed by a novel filtering approach based on least median of squares fitting and the forward search outlier detection method. The spatial accuracy of the method is measured using ten thoracic CT image sets and large samples of expert determined landmarks (available at www.dir-lab.com). The LFC method produces an average error within the intra-observer error on eight of the ten cases, indicating that the method is capable of achieving a high spatial accuracy for thoracic CT registration. PMID:22797602

  8. Tracking lava flow emplacement on the east rift zone of Kilauea, Hawai’i with synthetic aperture radar (SAR) coherence

    USGS Publications Warehouse

    Dietterich, Hannah R.; Poland, Michael P.; Schmidt, David; Cashman, Katharine V.; Sherrod, David R.; Espinosa, Arkin Tapia

    2012-01-01

    Lava flow mapping is both an essential component of volcano monitoring and a valuable tool for investigating lava flow behavior. Although maps are traditionally created through field surveys, remote sensing allows an extraordinary view of active lava flows while avoiding the difficulties of mapping on location. Synthetic aperture radar (SAR) imagery, in particular, can detect changes in a flow field by comparing two images collected at different times with SAR coherence. New lava flows radically alter the scattering properties of the surface, making the radar signal decorrelated in SAR coherence images. We describe a new technique, SAR Coherence Mapping (SCM), to map lava flows automatically from coherence images independent of look angle or satellite path. We use this approach to map lava flow emplacement during the Pu‘u ‘Ō‘ō-Kupaianaha eruption at Kīlauea, Hawai‘i. The resulting flow maps correspond well with field mapping and better resolve the internal structure of surface flows, as well as the locations of active flow paths. However, the SCM technique is only moderately successful at mapping flows that enter vegetation, which is also often decorrelated between successive SAR images. Along with measurements of planform morphology, we are able to show that the length of time a flow stays decorrelated after initial emplacement is linearly related to the flow thickness. Finally, we use interferograms obtained after flow surfaces become correlated to show that persistent decorrelation is caused by post-emplacement flow subsidence.

  9. Tracking lava flow emplacement on the east rift zone of Kīlauea, Hawai‘i, with synthetic aperture radar coherence

    NASA Astrophysics Data System (ADS)

    Dietterich, Hannah R.; Poland, Michael P.; Schmidt, David A.; Cashman, Katharine V.; Sherrod, David R.; Espinosa, Arkin Tapia

    2012-05-01

    Lava flow mapping is both an essential component of volcano monitoring and a valuable tool for investigating lava flow behavior. Although maps are traditionally created through field surveys, remote sensing allows an extraordinary view of active lava flows while avoiding the difficulties of mapping on location. Synthetic aperture radar (SAR) imagery, in particular, can detect changes in a flow field by comparing two images collected at different times with SAR coherence. New lava flows radically alter the scattering properties of the surface, making the radar signal decorrelated in SAR coherence images. We describe a new technique, SAR Coherence Mapping (SCM), to map lava flows automatically from coherence images independent of look angle or satellite path. We use this approach to map lava flow emplacement during the Pu`u `Ō`ō-Kupaianaha eruption at Kīlauea, Hawai`i. The resulting flow maps correspond well with field mapping and better resolve the internal structure of surface flows, as well as the locations of active flow paths. However, the SCM technique is only moderately successful at mapping flows that enter vegetation, which is also often decorrelated between successive SAR images. Along with measurements of planform morphology, we are able to show that the length of time a flow stays decorrelated after initial emplacement is linearly related to the flow thickness. Finally, we use interferograms obtained after flow surfaces become correlated to show that persistent decorrelation is caused by post-emplacement flow subsidence.

  10. Thermography-based blood flow imaging in human skin of the hands and feet: a spectral filtering approach.

    PubMed

    Sagaidachnyi, A A; Fomin, A V; Usanov, D A; Skripal, A V

    2017-02-01

    The determination of the relationship between skin blood flow and skin temperature dynamics is the main problem in thermography-based blood flow imaging. Oscillations in skin blood flow are the source of thermal waves propagating from micro-vessels toward the skin's surface, as assumed in this study. This hypothesis allows us to use equations for the attenuation and dispersion of thermal waves for converting the temperature signal into the blood flow signal, and vice versa. We developed a spectral filtering approach (SFA), which is a new technique for thermography-based blood flow imaging. In contrast to other processing techniques, the SFA implies calculations in the spectral domain rather than in the time domain. Therefore, it eliminates the need to solve differential equations. The developed technique was verified within 0.005-0.1 Hz, including the endothelial, neurogenic and myogenic frequency bands of blood flow oscillations. The algorithm for an inverse conversion of the blood flow signal into the skin temperature signal is addressed. The examples of blood flow imaging of hands during cuff occlusion and feet during heating of the back are illustrated. The processing of infrared (IR) thermograms using the SFA allowed us to restore the blood flow signals and achieve correlations of about 0.8 with a waveform of a photoplethysmographic signal. The prospective applications of the thermography-based blood flow imaging technique include non-contact monitoring of the blood supply during engraftment of skin flaps and burns healing, as well the use of contact temperature sensors to monitor low-frequency oscillations of peripheral blood flow.

  11. Video monitoring in the Gadria debris flow catchment: preliminary results of large scale particle image velocimetry (LSPIV)

    NASA Astrophysics Data System (ADS)

    Theule, Joshua; Crema, Stefano; Comiti, Francesco; Cavalli, Marco; Marchi, Lorenzo

    2015-04-01

    Large scale particle image velocimetry (LSPIV) is a technique mostly used in rivers to measure two dimensional velocities from high resolution images at high frame rates. This technique still needs to be thoroughly explored in the field of debris flow studies. The Gadria debris flow monitoring catchment in Val Venosta (Italian Alps) has been equipped with four MOBOTIX M12 video cameras. Two cameras are located in a sediment trap located close to the alluvial fan apex, one looking upstream and the other looking down and more perpendicular to the flow. The third camera is in the next reach upstream from the sediment trap at a closer proximity to the flow. These three cameras are connected to a field shelter equipped with power supply and a server collecting all the monitoring data. The fourth camera is located in an active gully, the camera is activated by a rain gauge when there is one minute of rainfall. Before LSPIV can be used, the highly distorted images need to be corrected and accurate reference points need to be made. We decided to use IMGRAFT (an opensource image georectification toolbox) which can correct distorted images using reference points and camera location, and then finally rectifies the batch of images onto a DEM grid (or the DEM grid onto the image coordinates). With the orthorectified images, we used the freeware Fudaa-LSPIV (developed by EDF, IRSTEA, and DeltaCAD Company) to generate the LSPIV calculations of the flow events. Calculated velocities can easily be checked manually because of the already orthorectified images. During the monitoring program (since 2011) we recorded three debris flow events at the sediment trap area (each with very different surge dynamics). The camera in the gully was in operation in 2014 which managed to record granular flows and rockfalls, which particle tracking may be more appropriate for velocity measurements. The four cameras allows us to explore the limitations of camera distance, angle, frame rate, and image quality.

  12. Intershot Analysis of Flows in DIII-D

    NASA Astrophysics Data System (ADS)

    Meyer, W. H.; Allen, S. L.; Samuell, C. M.; Howard, J.

    2016-10-01

    Analysis of the DIII-D flow diagnostic data require demodulation of interference images, and inversion of the resultant line integrated emissivity and flow (phase) images. Four response matrices are pre-calculated: the emissivity line integral and the line integral of the scalar product of the lines-of-site with the orthogonal unit vectors of parallel flow. Equilibrium data determines the relative weight of the component matrices used in the final flow inversion matrix. Serial processing has been used for the lower divertor viewing flow camera 800x600 pixel image. The full cross section viewing camera will require parallel processing of the 2160x2560 pixel image. We will discuss using a Posix thread pool and a Tesla K40c GPU in the processing of this data. Prepared by LLNL under Contract DE-AC52-07NA27344. This material is based upon work supported by the U.S. DOE, Office of Science, Fusion Energy Sciences.

  13. Spatially Resolved MR-Compatible Doppler Ultrasound: Proof of Concept for Triggering of Diagnostic Quality Cardiovascular MRI for Function and Flow Quantification at 3T.

    PubMed

    Crowe, Lindsey Alexandra; Manasseh, Gibran; Chmielewski, Aneta; Hachulla, Anne-Lise; Speicher, Daniel; Greiser, Andreas; Muller, Hajo; de Perrot, Thomas; Vallee, Jean-Paul; Salomir, Rares

    2018-02-01

    We demonstrate the use of a magnetic-resonance (MR)-compatible ultrasound (US) imaging probe using spatially resolved Doppler for diagnostic quality cardiovascular MR imaging (MRI) as an initial step toward hybrid US/MR fetal imaging. A newly developed technology for a dedicated MR-compatible phased array ultrasound-imaging probe acquired pulsed color Doppler carotid images, which were converted in near-real time to a trigger signal for cardiac cine and flow quantification MRI. Ultrasound and MR data acquired simultaneously were interference free. Conventional electrocardiogram (ECG) and the proposed spatially resolved Doppler triggering were compared in 10 healthy volunteers. A synthetic "false-triggered" image was retrospectively processed using metric optimized gating (MOG). Images were scored by expert readers, and sharpness, cardiac function and aortic flow were quantified. Four-dimensional (4-D) flow (two volunteers) showed feasibility of Doppler triggering over a long acquisition time. Imaging modalities were compatible. US probe positioning was stable and comfortable. Image quality scores and quantified sharpness were statistically equal for Doppler- and ECG-triggering (p ). ECG-, Doppler-triggered, and MOG ejection fractions were equivalent (p ), with false-triggered values significantly lower (p < 0.0005). Aortic flow showed no difference between ECG- and Doppler-triggered and MOG (p > 0.05). 4-D flow quantification gave consistent results between ECG and Doppler triggering. We report interference-free pulsed color Doppler ultrasound during MR data acquisition. Cardiovascular MRI of diagnostic quality was successfully obtained with pulsed color Doppler triggering. The hardware platform could further enable advanced free-breathing cardiac imaging. Doppler ultrasound triggering is applicable where ECG is compromised due to pathology or interference at higher magnetic fields, and where direct ECG is impossible, i.e., fetal imaging.

  14. Photoacoustic imaging velocimetry for flow-field measurement.

    PubMed

    Ma, Songbo; Yang, Sihua; Xing, Da

    2010-05-10

    We present the photoacoustic imaging velocimetry (PAIV) method for flow-field measurement based on a linear transducer array. The PAIV method is realized by using a Q-switched pulsed laser, a linear transducer array, a parallel data-acquisition equipment and dynamic focusing reconstruction. Tracers used to track liquid flow field were real-timely detected, two-dimensional (2-D) flow visualization was successfully reached, and flow parameters were acquired by measuring the movement of the tracer. Experimental results revealed that the PAIV method would be developed into 3-D imaging velocimetry for flow-field measurement, and potentially applied to research the security and targeting efficiency of optical nano-material probes. (c) 2010 Optical Society of America.

  15. Characterization of the NASA Langley Arc Heated Scramjet Test Facility Using NO PLIF

    NASA Technical Reports Server (NTRS)

    Kidd, F. Gray, III; Narayanaswamy, Venkateswaran; Danehy, Paul M.; Inman, Jennifer A.; Bathel, Brett F.; Cabell, Karen F.; Hass, Neal E.; Capriotti, Diego P.; Drozda, Tomasz G.; Johansen, Criag T.

    2014-01-01

    The nitric oxide planar laser-induced fluorescence (NO PLIF) imaging was used to characterize the air flow of the NASA Langley Arc Heated Scramjet Test Facility (AHSTF) configured with a Mach 6 nozzle. The arc raises the enthalpy of the test gas in AHSTF, producing nitric oxide. Nitric oxide persists as the temperature drops through the nozzle into the test section. NO PLIF was used to qualitatively visualize the flowfield at different experimental conditions, measure the temperature of the gas flow exiting the facility nozzle, and visualize the wave structure downstream of the nozzle at different operating conditions. Uniformity and repeatability of the nozzle flow were assessed. Expansion and compression waves on the free-jet shear layer as the nozzle flow expands into the test section were visualized. The main purpose of these experiments was to assess the uniformity of the NO in the freestream gas for planned experiments, in which NO PLIF will be used for qualitative fuel-mole-fraction sensitive imaging. The shot-to-shot fluctuations in the PLIF signal, caused by variations in the overall laser intensity as well as NO concentration and temperature variations in the flow was 20-25% of the mean signal, as determined by taking the standard deviation of a set of images obtained at constant conditions and dividing by the mean. The fluctuations within individual images, caused by laser sheet spatial variations as well as NO concentration and temperature variations in the flow, were about 28% of the mean in images, determined by taking standard deviation within individual images, dividing by the mean in the same image and averaged over the set of images. Applying an averaged laser sheet intensity correction reduced the within-image intensity fluctuations to about 10% suggesting that the NO concentration is uniform to within 10%. There was no significant difference in flow uniformity between the low and high enthalpy settings. While not strictly quantitative, the temperature maps show qualitative agreement with the computations of the flow.

  16. Pore-scale Simulation and Imaging of Multi-phase Flow and Transport in Porous Media (Invited)

    NASA Astrophysics Data System (ADS)

    Crawshaw, J.; Welch, N.; Daher, I.; Yang, J.; Shah, S.; Grey, F.; Boek, E.

    2013-12-01

    We combine multi-scale imaging and computer simulation of multi-phase flow and reactive transport in rock samples to enhance our fundamental understanding of long term CO2 storage in rock formations. The imaging techniques include Confocal Laser Scanning Microscopy (CLSM), micro-CT and medical CT scanning, with spatial resolutions ranging from sub-micron to mm respectively. First, we report a new sample preparation technique to study micro-porosity in carbonates using CLSM in 3 dimensions. Second, we use micro-CT scanning to generate high resolution 3D pore space images of carbonate and cap rock samples. In addition, we employ micro-CT to image the processes of evaporation in fractures and cap rock degradation due to exposure to CO2 flow. Third, we use medical CT scanning to image spontaneous imbibition in carbonate rock samples. Our imaging studies are complemented by computer simulations of multi-phase flow and transport, using the 3D pore space images obtained from the scanning experiments. We have developed a massively parallel lattice-Boltzmann (LB) code to calculate the single phase flow field in these pore space images. The resulting flow fields are then used to calculate hydrodynamic dispersion using a novel scheme to predict probability distributions for molecular displacements using the LB method and a streamline algorithm, modified for optimal solid boundary conditions. We calculate solute transport on pore-space images of rock cores with increasing degree of heterogeneity: a bead pack, Bentheimer sandstone and Portland carbonate. We observe that for homogeneous rock samples, such as bead packs, the displacement distribution remains Gaussian with time increasing. In the more heterogeneous rocks, on the other hand, the displacement distribution develops a stagnant part. We observe that the fraction of trapped solute increases from the beadpack (0 %) to Bentheimer sandstone (1.5 %) to Portland carbonate (8.1 %), in excellent agreement with PFG-NMR experiments. We then use our preferred multi-phase model to directly calculate flow in pore space images of two different sandstones and observe excellent agreement with experimental relative permeabilities. Also we calculate cluster size distributions in good agreement with experimental studies. Our analysis shows that the simulations are able to predict both multi-phase flow and transport properties directly on large 3D pore space images of real rocks. Pore space images, left and velocity distributions, right (Yang and Boek, 2013)

  17. Integrating transient heterogeneity of non-photochemical quenching in shade-grown heterobaric leaves of avocado (Persea americana L.): responses to CO2 concentration, stomatal occlusion, dehydration and relative humidity.

    PubMed

    Takayama, Kotaro; King, Diana; Robinson, Sharon A; Osmond, Barry

    2013-11-01

    Long-lived shade leaves of avocado had extremely low rates of photosynthesis. Gas exchange measurements of photosynthesis were of limited use, so we resorted to Chl fluorescence imaging (CFI) and spot measurements to evaluate photosynthetic electron transport rates (ETRs) and non-photochemical quenching (NPQ). Imaging revealed a remarkable transient heterogeneity of NPQ during photosynthetic induction in these hypostomatous, heterobaric leaves, but was adequately integrated by spot measurements, despite long-lasting artifacts from repeated saturating flashes during assays. Major veins (mid-vein, first- and second-order veins) defined areas of more static large-scale heterogeneous NPQ, with more dynamic small-scale heterogeneity most strongly expressed in mesophyll cells between third- and fourth-order veins. Both responded to external CO2 concentration ([CO2]), occlusion of stomata with Vaseline™, leaf dehydration and relative humidity (RH). We interpreted these responses in terms of independent behavior of stomata in adjacent areoles that was largely expressed through CO2-limited photosynthesis. Heterogeneity was most pronounced and prolonged in the absence of net CO2 fixation in 100 p.p.m. [CO2] when respiratory and photorespiratory CO2 cycling constrained the inferred ETR to ~75% of values in 400 or 700 p.p.m. [CO2]. Likewise, sustained higher NPQ under Vaseline™, after dehydration or at low RH, also restricted ETR to ~75% of control values. Low NPQ in chloroplast-containing cells adjacent to major veins but remote from stomata suggested internal sources of high [CO2] in these tissues.

  18. The path to COVIS: A review of acoustic imaging of hydrothermal flow regimes

    NASA Astrophysics Data System (ADS)

    Bemis, Karen G.; Silver, Deborah; Xu, Guangyu; Light, Russ; Jackson, Darrell; Jones, Christopher; Ozer, Sedat; Liu, Li

    2015-11-01

    Acoustic imaging of hydrothermal flow regimes started with the incidental recognition of a plume on a routine sonar scan for obstacles in the path of the human-occupied submersible ALVIN. Developments in sonar engineering, acoustic data processing and scientific visualization have been combined to develop technology which can effectively capture the behavior of focused and diffuse hydrothermal discharge. This paper traces the development of these acoustic imaging techniques for hydrothermal flow regimes from their conception through to the development of the Cabled Observatory Vent Imaging Sonar (COVIS). COVIS has monitored such flow eight times a day for several years. Successful acoustic techniques for estimating plume entrainment, bending, vertical rise, volume flux, and heat flux are presented as is the state-of-the-art in diffuse flow detection.

  19. High-speed Particle Image Velocimetry Near Surfaces

    PubMed Central

    Lu, Louise; Sick, Volker

    2013-01-01

    Multi-dimensional and transient flows play a key role in many areas of science, engineering, and health sciences but are often not well understood. The complex nature of these flows may be studied using particle image velocimetry (PIV), a laser-based imaging technique for optically accessible flows. Though many forms of PIV exist that extend the technique beyond the original planar two-component velocity measurement capabilities, the basic PIV system consists of a light source (laser), a camera, tracer particles, and analysis algorithms. The imaging and recording parameters, the light source, and the algorithms are adjusted to optimize the recording for the flow of interest and obtain valid velocity data. Common PIV investigations measure two-component velocities in a plane at a few frames per second. However, recent developments in instrumentation have facilitated high-frame rate (> 1 kHz) measurements capable of resolving transient flows with high temporal resolution. Therefore, high-frame rate measurements have enabled investigations on the evolution of the structure and dynamics of highly transient flows. These investigations play a critical role in understanding the fundamental physics of complex flows. A detailed description for performing high-resolution, high-speed planar PIV to study a transient flow near the surface of a flat plate is presented here. Details for adjusting the parameter constraints such as image and recording properties, the laser sheet properties, and processing algorithms to adapt PIV for any flow of interest are included. PMID:23851899

  20. Measurement and control systems for an imaging electromagnetic flow metre.

    PubMed

    Zhao, Y Y; Lucas, G; Leeungculsatien, T

    2014-03-01

    Electromagnetic flow metres based on the principles of Faraday's laws of induction have been used successfully in many industries. The conventional electromagnetic flow metre can measure the mean liquid velocity in axisymmetric single phase flows. However, in order to achieve velocity profile measurements in single phase flows with non-uniform velocity profiles, a novel imaging electromagnetic flow metre (IEF) has been developed which is described in this paper. The novel electromagnetic flow metre which is based on the 'weight value' theory to reconstruct velocity profiles is interfaced with a 'Microrobotics VM1' microcontroller as a stand-alone unit. The work undertaken in the paper demonstrates that an imaging electromagnetic flow metre for liquid velocity profile measurement is an instrument that is highly suited for control via a microcontroller. © 2013 ISA Published by ISA All rights reserved.

  1. Flow Quantification by Nuclear Magnetic Resonance Imaging

    NASA Astrophysics Data System (ADS)

    Vu, Anthony Tienhuan

    1994-01-01

    In this dissertation, a robust method for the measurement and visualization of flow field in laminar, complex and turbulent flows by Nuclear Magnetic Resonance Imaging utilizing flow induced Adiabatic Fast Passage (AFP) principle will be presented. This dissertation focuses on the application of AFP in spatially resolvable size vessels. We first review two main flow effects in NMR: time-of-flight and phase dispersion. The discussion of NMR flow imaging application - flow measurements and NMR angiography will be given. The theoretical framework of adiabatic passage will be discussed in order to explain the principle of flow-induced adiabatic passage tagging for flow imaging applications. From a knowledge of the basic flow-induced adiabatic passage principle, we propose a multi-zone AFP excitation scheme to deal with flow in a curved tube, branches and constrictions, i.e. complex and turbulent flow regimes. The technique provides a quick and simple way to acquire flow profiles simultaneously at several locations and arbitrary orientations inside the field-of-view. The flow profile is the time-averaged evolution of the labeled flowing material. Results obtained using a carotid bifurcation and circular jet phantoms are similar to the previous experimental studies employing laser Doppler Anemometry, and other flow visualization techniques. In addition, the preliminary results obtained with a human volunteer support the feasibility of the technique for in vivo flow quantification. Finally, a quantitative comparison of flow measurement of the new proposed techniques with the more established Phase Contrast MRA was performed. The results show excellent correlation between the two methods and with the standard volumetric flow rate measurement indicating that the flow measurements obtained using this technique are reliable and accurate under various flow regimes.

  2. Directional synthetic aperture flow imaging.

    PubMed

    Jensen, Jørgen Arendt; Nikolov, Svetoslav Ivanov

    2004-09-01

    A method for flow estimation using synthetic aperture imaging and focusing along the flow direction is presented. The method can find the correct velocity magnitude for any flow angle, and full color flow images can be measured using only 32 to 128 pulse emissions. The approach uses spherical wave emissions with a number of defocused elements and a linear frequency-modulated pulse (chirp) to improve the signal-to-noise ratio. The received signals are dynamically focused along the flow direction and these signals are used in a cross-correlation estimator for finding the velocity magnitude. The flow angle is manually determined from the B-mode image. The approach can be used for both tissue and blood velocity determination. The approach was investigated using both simulations and a flow system with a laminar flow. The flow profile was measured with a commercial 7.5 MHz linear array transducer. A plastic tube with an internal diameter of 17 mm was used with an EcoWatt 1 pump generating a laminar, stationary flow. The velocity profile was measured for flow angles of 90 and 60 degrees. The RASMUS research scanner was used for acquiring radio frequency (RF) data from 128 elements of the array, using 8 emissions with 11 elements in each emission. A 20-micros chirp was used during emission. The RF data were subsequently beamformed off-line and stationary echo canceling was performed. The 60-degree flow with a peak velocity of 0.15 m/s was determined using 16 groups of 8 emissions, and the relative standard deviation was 0.36% (0.65 mm/s). Using the same setup for purely transverse flow gave a standard deviation of 1.2% (2.1 mm/s). Variation of the different parameters revealed the sensitivity to number of lines, angle deviations, length of correlation interval, and sampling interval. An in vivo image of the carotid artery and jugular vein of a healthy 29-year-old volunteer was acquired. A full color flow image using only 128 emissions could be made with a high-velocity precision.

  3. Neutron imaging of diabatic two-phase flows relevant to air conditioning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Geoghegan, Patrick J; Sharma, Vishaldeep

    The design of the evaporator of an air conditioning system relies heavily on heat transfer coefficients and pressure drop correlations that predominantly involve an estimate of the changing void fraction and the underlying two-phase flow regime. These correlations dictate whether the resulting heat exchanger is oversized or not and the amount of refrigerant charge necessary to operate. The latter is particularly important when dealing with flammable or high GWP refrigerants. Traditional techniques to measure the void fraction and visualize the flow are either invasive to the flow or occur downstream of the evaporator, where some of the flow distribution willmore » have changed. Neutron imaging has the potential to visualize two-phase flow in-situ where an aluminium heat exchanger structure becomes essentially transparent to the penetrating neutrons. The subatomic particles are attenuated by the passing refrigerant flow. The resulting image may be directly related to the void fraction and the overall picture provides a clear insight into the flow regime present. This work presents neutron images of the refrigerant Isopentane as it passes through the flow channels of an aluminium evaporator at flowrates relevant to air conditioning. The flow in a 4mm square macro channel is compared to that in a 250 m by 750 m rectangular microchannel in terms of void fraction and regime. All neutron imaging experiments were conducted at the High Flux Isotope Reactor, an Oak Ridge National Laboratory facility« less

  4. Generation of chemical movies: FT-IR spectroscopic imaging of segmented flows.

    PubMed

    Chan, K L Andrew; Niu, X; deMello, A J; Kazarian, S G

    2011-05-01

    We have previously demonstrated that FT-IR spectroscopic imaging can be used as a powerful, label-free detection method for studying laminar flows. However, to date, the speed of image acquisition has been too slow for the efficient detection of moving droplets within segmented flow systems. In this paper, we demonstrate the extraction of fast FT-IR images with acquisition times of 50 ms. This approach allows efficient interrogation of segmented flow systems where aqueous droplets move at a speed of 2.5 mm/s. Consecutive FT-IR images separated by 120 ms intervals allow the generation of chemical movies at eight frames per second. The technique has been applied to the study of microfluidic systems containing moving droplets of water in oil and droplets of protein solution in oil. The presented work demonstrates the feasibility of the use of FT-IR imaging to study dynamic systems with subsecond temporal resolution.

  5. Two-dimensional confocal laser scanning microscopy image correlation for nanoparticle flow velocimetry

    NASA Astrophysics Data System (ADS)

    Jun, Brian; Giarra, Matthew; Golz, Brian; Main, Russell; Vlachos, Pavlos

    2016-11-01

    We present a methodology to mitigate the major sources of error associated with two-dimensional confocal laser scanning microscopy (CLSM) images of nanoparticles flowing through a microfluidic channel. The correlation-based velocity measurements from CLSM images are subject to random error due to the Brownian motion of nanometer-sized tracer particles, and a bias error due to the formation of images by raster scanning. Here, we develop a novel ensemble phase correlation with dynamic optimal filter that maximizes the correlation strength, which diminishes the random error. In addition, we introduce an analytical model of CLSM measurement bias error correction due to two-dimensional image scanning of tracer particles. We tested our technique using both synthetic and experimental images of nanoparticles flowing through a microfluidic channel. We observed that our technique reduced the error by up to a factor of ten compared to ensemble standard cross correlation (SCC) for the images tested in the present work. Subsequently, we will assess our framework further, by interrogating nanoscale flow in the cell culture environment (transport within the lacunar-canalicular system) to demonstrate our ability to accurately resolve flow measurements in a biological system.

  6. Optical Flow for Flight and Wind Tunnel Background Oriented Schlieren Imaging

    NASA Technical Reports Server (NTRS)

    Smith, Nathanial T.; Heineck, James T.; Schairer, Edward T.

    2017-01-01

    Background oriented Schlieren images have historically been generated by calculating the observed pixel displacement between a wind-on and wind-o image pair using normalized cross-correlation. This work uses optical flow to solve the displacement fields which generate the Schlieren images. A well established method used in the computer vision community, optical flow is the apparent motion in an image sequence due to brightness changes. The regularization method of Horn and Schunck is used to create Schlieren images using two data sets: a supersonic jet plume shock interaction from the NASA Ames Unitary Plan Wind Tunnel, and a transonic flight test of a T-38 aircraft using a naturally occurring background, performed in conjunction with NASA Ames and Armstrong Research Centers. Results are presented and contrasted with those using normalized cross-correlation. The optical flow Schlieren images are found to provided significantly more detail. We apply the method to historical data sets to demonstrate the broad applicability and limitations of the technique.

  7. Study of optical techniques for the Ames unitary wind tunnel: Digital image processing, part 6

    NASA Technical Reports Server (NTRS)

    Lee, George

    1993-01-01

    A survey of digital image processing techniques and processing systems for aerodynamic images has been conducted. These images covered many types of flows and were generated by many types of flow diagnostics. These include laser vapor screens, infrared cameras, laser holographic interferometry, Schlieren, and luminescent paints. Some general digital image processing systems, imaging networks, optical sensors, and image computing chips were briefly reviewed. Possible digital imaging network systems for the Ames Unitary Wind Tunnel were explored.

  8. Imaging of the Finger Vein and Blood Flow for Anti-Spoofing Authentication Using a Laser and a MEMS Scanner.

    PubMed

    Lee, Jaekwon; Moon, Seunghwan; Lim, Juhun; Gwak, Min-Joo; Kim, Jae Gwan; Chung, Euiheon; Lee, Jong-Hyun

    2017-04-22

    A new authentication method employing a laser and a scanner is proposed to improve image contrast of the finger vein and to extract blood flow pattern for liveness detection. A micromirror reflects a laser beam and performs a uniform raster scan. Transmissive vein images were obtained, and compared with those of an LED. Blood flow patterns were also obtained based on speckle images in perfusion and occlusion. Curvature ratios of the finger vein and blood flow intensities were found to be nearly constant, regardless of the vein size, which validated the high repeatability of this scheme for identity authentication with anti-spoofing.

  9. Imaging of the Finger Vein and Blood Flow for Anti-Spoofing Authentication Using a Laser and a MEMS Scanner

    PubMed Central

    Lee, Jaekwon; Moon, Seunghwan; Lim, Juhun; Gwak, Min-Joo; Kim, Jae Gwan; Chung, Euiheon; Lee, Jong-Hyun

    2017-01-01

    A new authentication method employing a laser and a scanner is proposed to improve image contrast of the finger vein and to extract blood flow pattern for liveness detection. A micromirror reflects a laser beam and performs a uniform raster scan. Transmissive vein images were obtained, and compared with those of an LED. Blood flow patterns were also obtained based on speckle images in perfusion and occlusion. Curvature ratios of the finger vein and blood flow intensities were found to be nearly constant, regardless of the vein size, which validated the high repeatability of this scheme for identity authentication with anti-spoofing. PMID:28441728

  10. Laser speckle contrast imaging of cerebral blood flow of newborn mice at optical clearing

    NASA Astrophysics Data System (ADS)

    Timoshina, Polina A.; Zinchenko, Ekaterina M.; Tuchina, Daria K.; Sagatova, Madina M.; Semyachkina-Glushkovskaya, Oxana V.; Tuchin, Valery V.

    2017-03-01

    In this work, we consider the use of optical clearing agents to improve imaging quality of the cerebral blood flow of newborn mice. Aqueous 60%-glycerol solution, aqueous 70%-OmnipaqueTM(300) solution and OmnipaqueTM (300) solution in water/DMSO(25%/5%) were selected as the optical clearing agents. Laser speckle contrast imaging (LSCI) was used for imaging of cerebral blood flow in newborn mice brain during topical optical clearing of tissuesin the area of the fontanelle. These results demonstrate the effectiveness of glycerol and Omnipaque solutions as optical clearing agents for investigation of cerebral blood flow in newborn mice without scalp removing and skull thinning.

  11. Feasibility study of hidden flow imaging based on laser speckle technique using multiperspectives contrast images

    NASA Astrophysics Data System (ADS)

    Abookasis, David; Moshe, Tomer

    2014-11-01

    This paper demonstrates the insertion of lens array in the front of a CCD camera in a laser speckle imaging (LSI) like-technique to acquire multiple speckle reflectance projections for imaging blood flow in an intact biological tissue. In some of LSI applications, flow imaging is obtained by thinning or removing of the upper tissue layers to access blood vessels. In contrast, with the proposed approach flow imaging can be achieved while the tissue is intact. In the system, each lens from an hexagonal lens array observed the sample from slightly different perspectives and captured with a CCD camera. In the computer, these multiview raw images are converted to speckled contrast maps. Then, a self-deconvolution shift-and-add algorithm is employed for processing yields high contrast flow information. The method is experimentally validated first with a plastic tube filled with scattering liquid running at different controlled flow rates hidden in a biological tissue and then extensively tested for imaging of cerebral blood flow in an intact rodent head experience different conditions. A total of fifteen mice were used in the experiments divided randomly into three groups as follows: Group 1 (n=5) consisted of injured mice experience hypoxic ischemic brain injury monitored for ~40 min. Group 2 (n=5) injured mice experience anoxic brain injury monitored up to 20 min. Group 3 (n=5) experience functional activation monitored up to ~35 min. To increase tissue transparency and the penetration depth of photons through head tissue layers, an optical clearing method was employed. To our knowledge, this work presents for the first time the use of lens array in LSI scheme.

  12. Tomographic particle image velocimetry of desert locust wakes: instantaneous volumes combine to reveal hidden vortex elements and rapid wake deformation

    PubMed Central

    Bomphrey, Richard J.; Henningsson, Per; Michaelis, Dirk; Hollis, David

    2012-01-01

    Aerodynamic structures generated by animals in flight are unstable and complex. Recent progress in quantitative flow visualization has advanced our understanding of animal aerodynamics, but measurements have hitherto been limited to flow velocities at a plane through the wake. We applied an emergent, high-speed, volumetric fluid imaging technique (tomographic particle image velocimetry) to examine segments of the wake of desert locusts, capturing fully three-dimensional instantaneous flow fields. We used those flow fields to characterize the aerodynamic footprint in unprecedented detail and revealed previously unseen wake elements that would have gone undetected by two-dimensional or stereo-imaging technology. Vortex iso-surface topographies show the spatio-temporal signature of aerodynamic force generation manifest in the wake of locusts, and expose the extent to which animal wakes can deform, potentially leading to unreliable calculations of lift and thrust when using conventional diagnostic methods. We discuss implications for experimental design and analysis as volumetric flow imaging becomes more widespread. PMID:22977102

  13. Flow-like Features On Europa

    NASA Technical Reports Server (NTRS)

    1997-01-01

    This image shows features on Jupiter's moon Europa that may be 'flows' from ice volcanoes. It was taken by the Galileo spacecraft solid state imaging (CCD) system during its seventh orbit around Jupiter. North is to the top of the image. The sun illuminates the scene from the left, showing features with shapes similar to lava flows on Earth. Two such features can be seen in the northwest corner of the image. The southern feature appears to have flowed over a ridge along its western edge. Scientists use these types of relationships to determine which feature formed first. In this case, the ridge probably formed before the flow-like feature that covers it.

    The image, centered at 22.6 degrees north latitude and 106.7 degrees west longitude, covers an area of 180 by 215 kilometers (112 by 134 miles). The smallest distinguishable features in the image are about 1.1 kilometers (0.7 miles) across. This image was obtained on April 28, 1997, when Galileo was 27,590 kilometers (16,830 miles) from Europa.

    The Jet Propulsion Laboratory, Pasadena, CA manages the Galileo mission for NASA's Office of Space Science, Washington, DC. JPL is an operating division of California Institute of Technology (Caltech).

    This image and other images and data received from Galileo are posted on the World Wide Web, on the Galileo mission home page at URL http://galileo.jpl.nasa.gov. Background information and educational context for the images can be found at URL http://www.jpl.nasa.gov/galileo/sepo

  14. Flow Interactions and Control

    DTIC Science & Technology

    2012-03-08

    to-Use 3-D Camera For Measurements in Turbulent Flow Fields B Thurow, Auburn Near Mid Far Conventional imaging Plenoptic imaging Conventional 2...depth-of-field and blur  Reduced aperture (restricted angular information) leads to low signal levels Lightfield Imaging  Plenoptic camera records

  15. Off-surface infrared flow visualization

    NASA Technical Reports Server (NTRS)

    Manuel, Gregory S. (Inventor); Obara, Clifford J. (Inventor); Daryabeigi, Kamran (Inventor); Alderfer, David W. (Inventor)

    1993-01-01

    A method for visualizing off-surface flows is provided. The method consists of releasing a gas with infrared absorbing and emitting characteristics into a fluid flow and imaging the flow with an infrared imaging system. This method allows for visualization of off-surface fluid flow in-flight. The novelty of this method is found in providing an apparatus for flow visualization which is contained within the aircraft so as not to disrupt the airflow around the aircraft, is effective at various speeds and altitudes, and is longer-lasting than previous methods of flow visualization.

  16. Masks in Imaging Flow Cytometry

    PubMed Central

    Dominical, Venina; Samsel, Leigh; McCoy, J. Philip

    2016-01-01

    Data analysis in imaging flow cytometry incorporates elements of flow cytometry together with other aspects of morphological analysis of images. A crucial early step in this analysis is the creation of a mask to distinguish the portion of the image upon which further examination of specified features can be performed. Default masks are provided by the manufacturer of the imaging flow cytometer but additional custom masks can be created by the individual user for specific applications. Flawed or inaccurate masks can have a substantial negative impact on the overall analysis of a sample, thus great care must be taken to ensure the accuracy of masks. Here we discuss various types of masks and cite examples of their use. Furthermore we provide our insight for how to approach selecting and assessing the optimal mask for a specific analysis. PMID:27461256

  17. Imaging of molecular hydrogen and oxygen by single and two-photon fluorescence using laser and flashlamp sources

    NASA Technical Reports Server (NTRS)

    Diskin, Glenn S.; Lempert, Walter R.; Miles, Richard B.; Kumar, Vinod; Glesk, Ivan

    1991-01-01

    Two flow visualization techniques, i.e., simultaneous two-dimensional fluorescence imaging of H2 and O2 in a diffusion flame, and quasi-linear fluorescence imaging of O2, are presented. The first uses an injection-locked argon-fluoride excimer laser and a partial overlap of a two-photon ground state absorption in H2 with a single photon absorption from a vibrational level in O2. The second uses a simple, high-intensity ultraviolet flashlamp which provides a flux of photons in the 180-195 nm range, sufficient to produce a quasi-one-dimensional fluorescence image of hot/room temperature oxygen. Both techniques do not require that a seed material be introduced into the flow, they can image major flow constituents, and provide an instantaneous snapshot of the flow.

  18. High resolution light-sheet based high-throughput imaging cytometry system enables visualization of intra-cellular organelles

    NASA Astrophysics Data System (ADS)

    Regmi, Raju; Mohan, Kavya; Mondal, Partha Pratim

    2014-09-01

    Visualization of intracellular organelles is achieved using a newly developed high throughput imaging cytometry system. This system interrogates the microfluidic channel using a sheet of light rather than the existing point-based scanning techniques. The advantages of the developed system are many, including, single-shot scanning of specimens flowing through the microfluidic channel at flow rate ranging from micro- to nano- lit./min. Moreover, this opens-up in-vivo imaging of sub-cellular structures and simultaneous cell counting in an imaging cytometry system. We recorded a maximum count of 2400 cells/min at a flow-rate of 700 nl/min, and simultaneous visualization of fluorescently-labeled mitochondrial network in HeLa cells during flow. The developed imaging cytometry system may find immediate application in biotechnology, fluorescence microscopy and nano-medicine.

  19. Measuring Attitudes About Intimate Partner Violence Against Women: The ATT-IPV Scale

    PubMed Central

    Yount, Kathryn M.; VanderEnde, Kristin; Zureick-Brown, Sarah; Anh, Hoang Tu; Schuler, Sidney Ruth; Minh, Tran Hung

    2014-01-01

    In lower-income settings, women more often than men justify intimate partner violence (IPV). Yet, the role of measurement invariance across gender is unstudied. We developed the ATT-IPV scale to measure attitudes about physical violence against wives in 1,055 married men and women ages 18–50 in My Hao district, Vietnam. Across 10 items about transgressions of the wife, women more often than men agreed that a man had good reason to hit his wife (3 % to 92 %; 0 % to 67 %). In random split-half samples, one-factor exploratory factor analysis (EFA) (N1 = 527) and confirmatory factor analysis (CFA) (N2 = 528) models for nine items with sufficient variability had significant loadings (0.575–0.883; 0.502–0.897) and good fit (RMSEA = 0.068, 0.048; CFI = 0.951, 0.978, TLI = 0.935, 0.970). Three items had significant uniform differential item functioning (DIF) by gender, and adjustment for DIF revealed that measurement noninvariance was partially masking men’s lower propensity than women to justify IPV. A CFA model for the six items without DIF had excellent fit (RMSEA = 0.019, CFI = 0.994, TLI = 0.991) and an attitudinal gender gap similar to the DIF-adjusted nine-item model, suggesting that the six-item scale reliably measures attitudes about IPV across gender. Researchers should validate the scale in urban Vietnam and elsewhere and decompose DIF-adjusted gender attitudinal gaps. PMID:24846070

  20. Confirmatory Factor Analysis of the Patient Reported Outcomes Measurement Information System (PROMIS) Adult Domain Framework Using Item Response Theory Scores.

    PubMed

    Carle, Adam C; Riley, William; Hays, Ron D; Cella, David

    2015-10-01

    To guide measure development, National Institutes of Health-supported Patient reported Outcomes Measurement Information System (PROMIS) investigators developed a hierarchical domain framework. The framework specifies health domains at multiple levels. The initial PROMIS domain framework specified that physical function and symptoms such as Pain and Fatigue indicate Physical Health (PH); Depression, Anxiety, and Anger indicate Mental Health (MH); and Social Role Performance and Social Satisfaction indicate Social Health (SH). We used confirmatory factor analyses to evaluate the fit of the hypothesized framework to data collected from a large sample. We used data (n=14,098) from PROMIS's wave 1 field test and estimated domain scores using the PROMIS item response theory parameters. We then used confirmatory factor analyses to test whether the domains corresponded to the PROMIS domain framework as expected. A model corresponding to the domain framework did not provide ideal fit [root mean square error of approximation (RMSEA)=0.13; comparative fit index (CFI)=0.92; Tucker Lewis Index (TLI)=0.88; standardized root mean square residual (SRMR)=0.09]. On the basis of modification indices and exploratory factor analyses, we allowed Fatigue to load on both PH and MH. This model fit the data acceptably (RMSEA=0.08; CFI=0.97; TLI=0.96; SRMR=0.03). Our findings generally support the PROMIS domain framework. Allowing Fatigue to load on both PH and MH improved fit considerably.

  1. A confirmatory factor analytic validation of the Tinnitus Handicap Inventory.

    PubMed

    Kleinstäuber, Maria; Frank, Ina; Weise, Cornelia

    2015-03-01

    Because the postulated three-factor structure of the internationally widely used Tinnitus Handicap Inventory (THI) has not been confirmed yet by a confirmatory factor analytic approach this was the central aim of the current study. From a clinical setting, N=373 patients with chronic tinnitus completed the THI and further questionnaires assessing tinnitus-related and psychological variables. In order to analyze the psychometric properties of the THI, confirmatory factor analysis (CFA) and correlational analyses were conducted. CFA provided a statistically significant support for a better fit of the data to the hypothesized three-factor structure (RMSEA=.049, WRMR=1.062, CFI=.965, TLI=.961) than to a general factor model (RMSEA=.062, WRMR=1.258, CFI=.942, TLI=.937). The calculation of Cronbach's alpha as indicator of internal consistency revealed satisfactory values (.80-.91) with the exception of the catastrophic subscale (.65). High positive correlations of the THI and its subscales with other measures of tinnitus distress, anxiety, and depression, high negative correlations with tinnitus acceptance, moderate positive correlations with anxiety sensitivity, sleeping difficulties, tinnitus loudness, and small correlations with the Big Five personality dimensions confirmed construct validity. Results show that the THI is a highly reliable and valid measure of tinnitus-related handicap. In contrast to results of previous exploratory analyses the current findings speak for a three-factor in contrast to a unifactorial structure. Future research is needed to replicate this result in different tinnitus populations. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Psychometric assessment of scales measuring HIV public stigma, drug-use public stigma and fear of HIV infection among young adolescents and their parents

    PubMed Central

    Ha, Toan; Liu, Hongjie; Li, Jian; Nield, Jennifer; Lu, Zhouping

    2011-01-01

    The objective of this study was to design and assess measurement instruments that accurately measure the levels of stigma among individuals with a primarily collectivist culture. A cross-sectional study was conducted among middle school students and their parents or guardians in a rural area of China. Exploratory and confirmatory factor analyses were used to examine and determine the latent factors of the sub-scales of stigma respectively among students and their parents. Factor analyses identified three sub-scales: HIV public stigma (7 items), drug-use public stigma (9 items), and fear of HIV infection (7 items). There were no items with cross-loading onto multiple factors, supporting the distinctness of the constructs that these scales were meant to measure. Goodness of fit indices indicated that a three-factor solution fit the data at an acceptable level in the student sample (χ2/degree ratio = 1.98, CFI = 0.92, RMSEA = 0.055, SRMR = 0.057) and in the parent sample (χ2/degree ratio = 1.95, CFI = 0.91, RMSEA = 0.06, SRMR = 0.059). Reliability of the three scales was excellent (Cronbach’s alpha: 0.78–0.92 for students; 0.80–0.94 for parents or guardians) and stable across split samples and for the data as a whole. The scales are brief and suitable for use in developing countries where the collectivist culture prevails. PMID:21756072

  3. The factor structure of complex posttraumatic stress disorder in traumatized refugees.

    PubMed

    Nickerson, Angela; Cloitre, Marylene; Bryant, Richard A; Schnyder, Ulrich; Morina, Naser; Schick, Matthis

    2016-01-01

    The construct of complex posttraumatic stress disorder (CPTSD) has attracted much research attention in previous years, however it has not been systematically evaluated in individuals exposed to persecution and displacement. Given that CPTSD has been proposed as a diagnostic category in the ICD-11, it is important that it be examined in refugee groups. In the current study, we proposed to test, for the first time, the factor structure of CPTSD proposed for the ICD-11 in a sample of resettled treatment-seeking refugees. The study sample consisted of 134 traumatized refugees from a variety of countries of origin, with approximately 93% of the sample having been exposed to torture. We used confirmatory factor analysis to examine the factor structure of CPTSD in this sample and examined the sensitivity, specificity, positive predictive power and negative predictive power of individual items in relation to the CPTSD diagnosis. Findings revealed that a two-factor higher-order model of CPTSD comprising PTSD and Difficulties in Self-Organization (χ 2 (47)=57.322, p =0.144, RMSEA=0.041, CFI=0.981, TLI=0.974) evidenced superior fit compared to a one-factor higher-order model of CPTSD (χ 2 (48)=65.745, p =0.045, RMSEA=0.053, CFI=0.968, TLI=0.956). Overall, items evidenced strong sensitivity and negative predictive power, moderate positive predictive power, and poor specificity. Findings provide preliminary evidence for the validity of the CPTSD construct with highly traumatized treatment-seeking refugees.

  4. An Empirical Assessment of REBT Models of Psychopathology and Psychological Health in the Prediction of Anxiety and Depression Symptoms.

    PubMed

    Oltean, Horea-Radu; Hyland, Philip; Vallières, Frédérique; David, Daniel Ovidiu

    2017-11-01

    This study aimed to assess the validity of two models which integrate the cognitive (satisfaction with life) and affective (symptoms of anxiety and depression) aspects of subjective well-being within the framework of rational emotive behaviour therapy (REBT) theory; specifically REBT's theory of psychopathology and theory of psychological health. 397 Irish and Northern Irish undergraduate students completed measures of rational/irrational beliefs, satisfaction with life, and anxiety/depression symptoms. Structural equation modelling techniques were used in order to test our hypothesis within a cross-sectional design. REBT's theory of psychopathology (χ2 = 373.78, d.f. = 163, p < .001; comparative fit index (CFI) = .92; Tucker Lewis index (TLI) = .91; root mean square error of approximation (RMSEA) = .06 (95% CI = .05 to .07); standardized root mean square residual (SRMR) = .07) and psychological health (χ2 = 371.89, d.f. = 181, p < .001; CFI = .93; TLI = .92; RMSEA = .05 (95% CI = .04 to .06); SRMR = .06) provided acceptable fit of the data. Moreover, the psychopathology model explained 34% of variance in levels of anxiety/depression, while the psychological health model explained 33% of variance. This study provides important findings linking the fields of clinical and positive psychology within a comprehensible framework for both researchers and clinicians. Findings are discussed in relation to the possibility of more effective interventions, incorporating and targeting not only negative outcomes, but also positive concepts within the same model.

  5. Motivational Climate Sport Youth Scale: Measurement Invariance Across Gender and Five Different Sports.

    PubMed

    Monteiro, Diogo; Borrego, Carla Chicau; Silva, Carlos; Moutão, João; Marinho, Daniel Almeida; Cid, Luís

    2018-03-01

    The aim of this study was to analyze the psychometric properties of the Portuguese version of the Motivational Climate Sport Youth Scale (MCSYSp) and invariance across gender and different sports (swimming, soccer, handball, basketball, futsal). A total of 4,569 athletes (3,053 males, 1,516 females) from soccer (1,098), swimming (1,049), basketball (1,754), futsal (340), and handball (328) participated in this study, with ages between 10 and 20 years (M = 15.13; SD = 1.95). The results show that the original model (two factors/12 items) did not adjust to the data in a satisfactory way; therefore, it was necessary to change the model by removing four items (two from each factor). Subsequently, the model adjusted to the data in a satisfactory way (χ 2 = 499.84; df = 19; χ 2 /df = 26.30; p < .001; SRMR = .037; TLI = .923; CFI = .948; RMSEA = .074; IC90% .069-.080) and was invariant by gender and team sports (soccer, handball, basketball, futsal) (ΔCFK≤.01); however, it was not invariant between swimming and team sports (soccer, handball, basketball, futsal) (ΔCFI ≥ .01). In conclusion, the MCSYSp (two factors/eight items) is a valid and reliable choice that is transversal not only to gender, but also to the different studied team sports to measure the perception of the motivational climate in athletes. Future studies can research more deeply the invariance analysis between individual sports to better understand the invariance of the model between individual and team sports.

  6. Core and peripheral criteria of video game addiction in the game addiction scale for adolescents.

    PubMed

    Brunborg, Geir Scott; Hanss, Daniel; Mentzoni, Rune Aune; Pallesen, Ståle

    2015-05-01

    Assessment of video game addiction often involves measurement of peripheral criteria that indicate high engagement with games, and core criteria that indicate problematic use of games. A survey of the Norwegian population aged 16-74 years (N=10,081, response rate 43.6%) was carried out in 2013, which included the Gaming Addiction Scale for Adolescents (GAS). Confirmatory factor analysis showed that a two-factor structure, which separated peripheral criteria from core criteria, fitted the data better (CFI=0.963; RMSEA=0.058) compared to the original one-factor solution where all items are determined to load only on one factor (CFI=0.905, RMSEA=0.089). This was also found when we analyzed men aged ≤33 years, men aged >33 years, women aged ≤33 years, and women aged >33 years separately. This indicates that the GAS measures both engagement and problems related to video games. Multi-group measurement invariance testing showed that the factor structure was valid in all four groups (configural invariance) for the two-factor structure but not for the one-factor structure. A novel approach to categorization of problem gamers and addicted gamers where only the core criteria items are used (the CORE 4 approach) was compared to the approach where all items are included (the GAS 7 approach). The current results suggest that the CORE 4 approach might be more appropriate for classification of problem gamers and addicted gamers compared to the GAS 7 approach.

  7. Physical Activity, Sleep, and Nutrition Do Not Predict Cognitive Performance in Young and Middle-Aged Adults.

    PubMed

    Gijselaers, Hieronymus J M; Elena, Barberà; Kirschner, Paul A; de Groot, Renate H M

    2016-01-01

    Biological lifestyle factors (BLFs) such as physical activity, sleep, and nutrition play a role in cognitive functioning. Research concerning the relation between BLFs and cognitive performance is scarce however, especially in young and middle-aged adults. Research has not yet focused on a multidisciplinary approach with respect to this relation in the abovementioned population, where lifestyle habits are more stable. The aim of this study was to examine the contribution of these BLFs to cognitive performance. Path analysis was conducted in an observational study in which 1131 adults were analyzed using a cross-validation approach. Participants provided information on physical activity, sedentary behavior, chronotype, sleep duration, sleep quality, and the consumption of breakfast, fish, and caffeine via a survey. Their cognitive performance was measured using objective digital cognitive tests. Exploration yielded a predictive cohesive model that fitted the data properly, χ(2) /df = 0.8, CFI = 1.00, RMSEA < 0.001, SRMR = 0.016. Validation of the developed model indicated that the model fitted the data satisfactorily, χ(2) /df = 2.75, CFI = 0.95, RMSEA < 0.056, SRMR = 0.035. None of the variables within the BLFs were predictive for any of the cognitive performance measures, except for sedentary behavior. Although sedentary behavior was positively predictive for processing speed its contribution was small and unclear. The results indicate that the variables within the BLFs do not predict cognitive performance in young and middle-aged adults.

  8. Redesign and initial validation of an instrument to assess the motivational qualities of music in exercise: the Brunel Music Rating Inventory-2.

    PubMed

    Karageorghis, Costas I; Priest, David-Lee; Terry, Peter C; Chatzisarantis, Nikos L D; Lane, Andrew M

    2006-08-01

    In the present study, a measure to assess the motivational qualities of music in exercise was redesigned, extending previous research efforts (Karageorghis et al., 1999). The original measure, the Brunel Music Rating Inventory (BMRI), had shown limitations in its factor structure and its applicability to non-experts in music selection. Redesign of the BMRI used in-depth interviews with eight participants (mean age 31.9 years, s = 8.9 years) to establish the initial item pool, which was examined using a series of confirmatory factor analyses. A single-factor model provided a good fit across three musical selections with different motivational qualities (comparative fit index, CFI: 0.95-0.98; standardized root mean residual, SRMR: 0.03-0.05). The single-factor model also demonstrated acceptable fit across two independent samples and both sexes using one piece of music (CFI: 0.86-1.00; SRMR: 0.04-0.07). The BMRI was designed for experts in selecting music for exercise (e.g. dance aerobic instructors), whereas the BMRI-2 can be used both by exercise instructors and participants. The psychometric properties of the BMRI-2 are stronger than those of the BMRI and it is easier to use. The BMRI-2 provides a valid and internally consistent tool by which music can be selected to accompany a bout of exercise or a training session. Furthermore, the BMRI-2 enables researchers to standardize music in experimental protocols involving exercise-related tasks.

  9. A reduced factor structure for the PROQOL-HIV questionnaire provided reliable indicators of health-related quality of life.

    PubMed

    Lalanne, Christophe; Chassany, Olivier; Carrieri, Patrizia; Marcellin, Fabienne; Armstrong, Andrew R; Lert, France; Spire, Bruno; Dray-Spira, Rosemary; Duracinsky, Martin

    2016-04-01

    To identify a simplified factor structure for the PROQOL-human immunodeficiency virus (HIV) questionnaire to improve the measurement of the health-related quality of life (HRQL) of HIV-positive patients in clinical care and research settings. HRQL data were collected using the eight-dimension PROQOL-HIV questionnaire from 2,537 patients (VESPA2 study). Exploratory factor analysis (EFA) and confirmatory factor analysis (CFA) validated a simpler four-factor structure and assessed measurement invariance (MI). Multigroup analysis assessed the effect of sex, age, and antiretroviral therapy (ART) on the resulting factor scores. Correlations with symptom and Short Form (SF)-12 self-reports assessed convergent validity. Item analysis, EFA, and CFAs confirmed the validity [comparative fit index (CFI), 0.948; root mean square error of approximation, 0.064] and reliability (α's ≥ 0.8) of four dimensions: physical health and symptoms, health concerns and mental distress, social and intimate relationships, and treatment-related impact. Strong MI was demonstrated across sex and age (decrease in CFI <0.01). A multiple-cause multiple-indicator model indicated that HRQL correlated as expected with sex, age, and the ART status. Correlations of HRQL, symptom reports, and SF-12 scores evidenced convergent validity criterion. The simplified factor structure and scoring scheme for PROQOL-HIV will allow clinicians to monitor with greater reliability the HRQL of patients in clinical care and research settings. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Development of the central nervous system functions in rat pups prenatally exposed to alcohol (study on the behavioural teratology of ethanol in CFY rat pups).

    PubMed

    Lehotzky, K; Ungváry, G; Szeberényi, J M; Kiss, A

    1988-01-01

    As a model of fetal alcohol syndrome (FAS) the rate of the maturation of the functions of the central nervous system was studied in the offspring of pregnant CFY rats receiving (from the 7th-15th day of gestation) either oral ethanol treatment or liquid diet containing ethanol. Both types of exposure caused numerous behavioural impairments, besides high perinatal mortality also the opening of the eyes and ears, and the appearance of postural reflexes were delayed. The newborn rats could be characterized by hyperactivity and weak motor coordination. The learning capacity, the avoidance conditioned reflexes was the poorest in the case of the offspring of mothers kept on liquid diet, containing alcohol, the latency of the conditioned response was significantly lenghtened. During reconditioning, in the case of the sexually already mature pups, the weakest performance was observed in the offspring of mothers having received oral alcohol treatment. This findings indicated, on one hand, that the retardation ceased and, on the other, that the learning and memory impairments caused by oral alcohol exposure was persistent. Following prenatal alcohol exposure carried out by different methods the neurotoxic effect, the retardation of the rate of maturation of the central nervous functions, and the adaptive mechanisms were all affected to different extent. Besides alcohol exposure also other factors (relative protein insufficiency, malnutrition) may be involved in the pathomechanism of the above mentioned phenomena.

  11. Velocity landscape correlation resolves multiple flowing protein populations from fluorescence image time series.

    PubMed

    Pandžić, Elvis; Abu-Arish, Asmahan; Whan, Renee M; Hanrahan, John W; Wiseman, Paul W

    2018-02-16

    Molecular, vesicular and organellar flows are of fundamental importance for the delivery of nutrients and essential components used in cellular functions such as motility and division. With recent advances in fluorescence/super-resolution microscopy modalities we can resolve the movements of these objects at higher spatio-temporal resolutions and with better sensitivity. Previously, spatio-temporal image correlation spectroscopy has been applied to map molecular flows by correlation analysis of fluorescence fluctuations in image series. However, an underlying assumption of this approach is that the sampled time windows contain one dominant flowing component. Although this was true for most of the cases analyzed earlier, in some situations two or more different flowing populations can be present in the same spatio-temporal window. We introduce an approach, termed velocity landscape correlation (VLC), which detects and extracts multiple flow components present in a sampled image region via an extension of the correlation analysis of fluorescence intensity fluctuations. First we demonstrate theoretically how this approach works, test the performance of the method with a range of computer simulated image series with varying flow dynamics. Finally we apply VLC to study variable fluxing of STIM1 proteins on microtubules connected to the plasma membrane of Cystic Fibrosis Bronchial Epithelial (CFBE) cells. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. Buried Crater

    NASA Image and Video Library

    2002-12-04

    With a location roughly equidistant between two of the largest volcanic constructs on the planet, the fate of the approximately 50 km 31 mile impact crater in this image from NASA Mars Odyssey was sealed. It has been buried to the rim by lava flows. The MOLA context image shows pronounced flow lobes surrounding the crater, a clear indication of the most recent episode of volcanism that could have contributed to its infilling. Breaches in the rim are clearly evident in the image and suggest locations through which lavas could have flowed. These openings appear to be limited to the west side of the crater. Other craters in the area are nearly obliterated by the voluminous lava flows, further demonstrating one of the means by which Mars renews its surface. The MOLA context image shows pronounced flow lobes surrounding the crater, a clear indication of the most recent episode of volcanism that could have contributed to its infilling. Breaches in the rim are clearly evident in the image and suggest locations through which lavas could have flowed. These openings appear to be limited to the west side of the crater. Other craters in the area are nearly obliterated by the voluminous lava flows, further demonstrating one of the means by which Mars renews its surface. http://photojournal.jpl.nasa.gov/catalog/PIA04018

  13. Balanced steady state free precession for arterial spin labeling MRI: Initial experience for blood flow mapping in human brain, retina, and kidney.

    PubMed

    Park, Sung-Hong; Wang, Danny J J; Duong, Timothy Q

    2013-09-01

    We implemented pseudo-continuous ASL (pCASL) with 2D and 3D balanced steady state free precession (bSSFP) readout for mapping blood flow in the human brain, retina, and kidney, free of distortion and signal dropout, which are typically observed in the most commonly used echo-planar imaging acquisition. High resolution functional brain imaging in the human visual cortex was feasible with 3D bSSFP pCASL. Blood flow of the human retina could be imaged with pCASL and bSSFP in conjunction with a phase cycling approach to suppress the banding artifacts associated with bSSFP. Furthermore, bSSFP based pCASL enabled us to map renal blood flow within a single breath hold. Control and test-retest experiments suggested that the measured blood flow values in retina and kidney were reliable. Because there is no specific imaging tool for mapping human retina blood flow and the standard contrast agent technique for mapping renal blood flow can cause problems for patients with kidney dysfunction, bSSFP based pCASL may provide a useful tool for the diagnosis of retinal and renal diseases and can complement existing imaging techniques. Copyright © 2013 Elsevier Inc. All rights reserved.

  14. Computed Tomography 3-D Imaging of the Metal Deformation Flow Path in Friction Stir Welding

    NASA Technical Reports Server (NTRS)

    Schneider, Judy; Beshears, Ronald; Nunes, Arthur C., Jr.

    2005-01-01

    In friction stir welding (FSW), a rotating threaded pin tool is inserted into a weld seam and literally stirs the edges of the seam together. To determine optimal processing parameters for producing a defect free weld, a better understanding of the resulting metal deformation flow path is required. Marker studies are the principal method of studying the metal deformation flow path around the FSW pin tool. In our study, we have used computed tomography (CT) scans to reveal the flow pattern of a lead wire embedded in a FSW weld seam. At the welding temperature of aluminum, the lead becomes molten and is carried with the macro-flow of the weld metal. By using CT images, a 3-dimensional (3D) image of the lead flow pattern can be reconstructed. CT imaging was found to be a convenient and comprehensive way of collecting and displaying tracer data. It marks an advance over previous more tedious and ambiguous radiographic/metallographic data collection methods.

  15. The application of a unique flow modeling technique to complex combustion systems

    NASA Astrophysics Data System (ADS)

    Waslo, J.; Hasegawa, T.; Hilt, M. B.

    1986-06-01

    This paper describes the application of a unique three-dimensional water flow modeling technique to the study of complex fluid flow patterns within an advanced gas turbine combustor. The visualization technique uses light scattering, coupled with real-time image processing, to determine flow fields. Additional image processing is used to make concentration measurements within the combustor.

  16. Venus - Lakshmi Region

    NASA Technical Reports Server (NTRS)

    1991-01-01

    This Magellan image is centered at 55 degrees north latitude, 348.5 degrees longitude, in the eastern Lakshmi region of Venus. This image, which is of an area 300 kilometers (180 miles) in width and 230 kilometers (138 miles) in length, is a mosaic of orbits 458 through 484. The image shows a relatively flat plains region composed of many lava flows. The dark flows mostly likely represent smooth lava flows similar to 'pahoehoe' flows on Earth while the brighter lava flows are rougher flows similar to 'aa' flows on Earth. (The terms 'pahoehoe' and 'aa' refer to textures of lava with pahoehoe a smooth or ropey surface, and aa a rough, clinkery texture). The rougher flows are brighter because the rough surface returns more energy to the radar than the smooth flows. Situated on top of the lava flows are three dark splotches. Because of the thick Venusian atmosphere, the small impactors break up before they reached the surface. Only the fragments from the broken up impactor are deposited on the surface and these fragments produce the dark splotches in this image. The splotch at the far right (east) has a crater centered in it, indicating that the impactor was not completely destroyed during its journey through the atmosphere. The dark splotches in the center and to the far left in this image each represent an impactor that was broken up into small fragments that did not penetrate the surface to produce a crater. The dark splotch at the left has been modified by the wind. A southwest northeast wind flow has moved some of the debris making up the splotch to the northeast where it has piled up against some small ridges.

  17. Identification of the inflow zone of unruptured cerebral aneurysms: comparison of 4D flow MRI and 3D TOF MRA data.

    PubMed

    Futami, K; Sano, H; Misaki, K; Nakada, M; Ueda, F; Hamada, J

    2014-07-01

    The hemodynamics of the inflow zone of cerebral aneurysms may be a key factor in coil compaction and recanalization after endovascular coil embolization. We performed 4D flow MR imaging in conjunction with 3D TOF MRA and compared their ability to identify the inflow zone of unruptured cerebral aneurysms. This series comprised 50 unruptured saccular cerebral aneurysms in 44 patients. Transluminal color-coded 3D MRA images were created by selecting the signal-intensity ranges on 3D TOF MRA images that corresponded with both the luminal margin and the putative inflow. 4D flow MR imaging demonstrated the inflow zone and yielded inflow velocity profiles for all 50 aneurysms. In 18 of 24 lateral-projection aneurysms (75%), the inflow zone was located distally on the aneurysmal neck. The maximum inflow velocity ranged from 285 to 922 mm/s. On 4D flow MR imaging and transluminal color-coded 3D MRA studies, the inflow zone of 32 aneurysms (64%) was at a similar location. In 91% of aneurysms whose neck section plane angle was <30° with respect to the imaging section direction on 3D TOF MRA, depiction of the inflow zone was similar on transluminal color-coded 3D MRA and 4D flow MR images. 4D flow MR imaging can demonstrate the inflow zone and provide inflow velocity profiles. In aneurysms whose angle of the neck-section plane is obtuse vis-a-vis the imaging section on 3D TOF MRA scans, transluminal color-coded 3D MRA may depict the inflow zone reliably. © 2014 by American Journal of Neuroradiology.

  18. Portable Fluorescence Imaging System for Hypersonic Flow Facilities

    NASA Technical Reports Server (NTRS)

    Wilkes, J. A.; Alderfer, D. W.; Jones, S. B.; Danehy, P. M.

    2003-01-01

    A portable fluorescence imaging system has been developed for use in NASA Langley s hypersonic wind tunnels. The system has been applied to a small-scale free jet flow. Two-dimensional images were taken of the flow out of a nozzle into a low-pressure test section using the portable planar laser-induced fluorescence system. Images were taken from the center of the jet at various test section pressures, showing the formation of a barrel shock at low pressures, transitioning to a turbulent jet at high pressures. A spanwise scan through the jet at constant pressure reveals the three-dimensional structure of the flow. Future capabilities of the system for making measurements in large-scale hypersonic wind tunnel facilities are discussed.

  19. Validation of a Multimodality Flow Phantom and Its Application for Assessment of Dynamic SPECT and PET Technologies.

    PubMed

    Gabrani-Juma, Hanif; Clarkin, Owen J; Pourmoghaddas, Amir; Driscoll, Brandon; Wells, R Glenn; deKemp, Robert A; Klein, Ran

    2017-01-01

    Simple and robust techniques are lacking to assess performance of flow quantification using dynamic imaging. We therefore developed a method to qualify flow quantification technologies using a physical compartment exchange phantom and image analysis tool. We validate and demonstrate utility of this method using dynamic PET and SPECT. Dynamic image sequences were acquired on two PET/CT and a cardiac dedicated SPECT (with and without attenuation and scatter corrections) systems. A two-compartment exchange model was fit to image derived time-activity curves to quantify flow rates. Flowmeter measured flow rates (20-300 mL/min) were set prior to imaging and were used as reference truth to which image derived flow rates were compared. Both PET cameras had excellent agreement with truth ( [Formula: see text]). High-end PET had no significant bias (p > 0.05) while lower-end PET had minimal slope bias (wash-in and wash-out slopes were 1.02 and 1.01) but no significant reduction in precision relative to high-end PET (<15% vs. <14% limits of agreement, p > 0.3). SPECT (without scatter and attenuation corrections) slope biases were noted (0.85 and 1.32) and attributed to camera saturation in early time frames. Analysis of wash-out rates from non-saturated, late time frames resulted in excellent agreement with truth ( [Formula: see text], slope = 0.97). Attenuation and scatter corrections did not significantly impact SPECT performance. The proposed phantom, software and quality assurance paradigm can be used to qualify imaging instrumentation and protocols for quantification of kinetic rate parameters using dynamic imaging.

  20. Morphologic and thermophysical characteristics of lava flows southwest of Arsia Mons, Mars

    NASA Astrophysics Data System (ADS)

    Crown, David A.; Ramsey, Michael S.

    2017-08-01

    The morphologic and thermophysical characteristics of part of the extensive lava flow fields southwest of Arsia Mons (22.5-27.5°S, 120-130°W) have been examined using a combination of orbital VNIR and TIR datasets. THEMIS images provide context for the regional geology and record diurnal temperature variability that is diverse and unusual for flow surfaces in such close proximity. CTX images were used to distinguish dominant flow types and assess local age relationships between individual lava flows. CTX and HiRISE images provide detailed information on flow surface textures and document aeolian effects as they reveal fine-grained deposits in many low-lying areas of the flow surfaces as well as small patches of transverse aeolian ridges. Although this region is generally dust-covered and has a lower overall thermal inertia, the THEMIS data indicate subtle spectral variations within the population of lava flows studied. These variations could be due to compositional differences among the flows or related to mixing of flow and aeolian materials. Specific results regarding flow morphology include: a) Two main lava flow types (bright, rugged and dark, smooth as observed in CTX images) dominate the southwest Arsia Mons/NE Daedalia Planum region; b) the bright, rugged flows have knobby, ridged, and/or platy surface textures, commonly have medial channel/levee systems, and may have broad distal lobes; c) the dark, smooth flows extend from distributary systems that consist of combinations of lava channels, lava tubes, and/or sinuous ridges and plateaus; and d) steep-sided, terraced margins, digitate breakout lobes, and smooth-surfaced plateaus along lava channel/tube systems are interpreted as signatures of flow inflation within the dark, smooth flow type. These flows exhibit smoother upper surfaces, are thinner, and have more numerous, smaller lobes, which, along with their the channel-/tube-fed nature, indicate a lower viscosity lava than for the bright, rugged flows. Flow patterns and local interfingering and overlapping relationships are delineated in CTX images and allow reconstruction of the complex flow field surfaces. Darker channel-/tube-fed flows are generally younger than adjacent thicker, bright, rugged flows; however, the diversity and complexity of temporal relationships observed, along with the thermophysical variability, suggests that lava sources with different eruptive styles and magnitudes and/or lavas that experienced different local emplacement conditions were active contemporaneously.

  1. A New Submersible Imaging-in-flow Instrument to Monitor Nano- and Microplankton: Imaging FlowCytobot

    NASA Astrophysics Data System (ADS)

    Olson, R. J.; Sosik, H. M.; Shalapyonok, A.

    2004-12-01

    Understanding of how coastal plankton communities are regulated has traditionally been limited by undersampling, but cabled observatories now provide opportunities to deploy submersible sensors that have high power and data transmission requirements. We have developed an in situ instrument to carry out high-resolution, long term monitoring of phytoplankton and microzooplankton in the size range 10 to100 micrometers, to be deployed at cabled research facilities such as the Martha's Vineyard Coastal Observatory (MVCO). The new instrument is designed to complement FlowCytobot, a submersible flow cytometer currently deployed at MVCO that uses fluorescence and light scattering signals from a laser beam to characterize the smallest phytoplankton cells (less than 10 micrometers). Imaging FlowCytobot uses a combination of flow cytometric and video technology to capture images of organisms for identification and to measure chlorophyll fluorescence associated with each image. Images will be classified using neural net software, while the measurements of chlorophyll fluorescence will allow us to discriminate heterotrophic from phototrophic cells. The new instrument, like the original FlowCytobot is autonomous but remotely programmable. It utilizes a computer controlled syringe pump and distribution valve that allows periodic anti-fouling treatment and analysis of standard beads. Samples are analyzed continuously (0.25 to 2.5 ml per min) and data is sent over a fiber optic link to a remote computer for analysis. Preliminary results indicate that we can detect cells as small as 5 micrometers and discriminate several taxa of diatoms and dinoflagellates.

  2. [New classification of Crowe type IV developmental dysplasia of the hip].

    PubMed

    Ma, Hai-yang; Zhou, Yong-gang; Zheng, Chong; Cao, Wen-zhe; Wang Sen; Wu, Wen-ming; Piao, Shang; Du, Yin-qiao

    2016-02-01

    To compare differences between Crowe IV developmental dysplasia of the hip (DDH) with secondary acetabulum and Crowe IV DDH without secondary acetabulum,and determine whether it is necessary to divide Crowe IV DDH into two subtypes. From June 2007 to May 2015,145 hips of 112 Crowe N patients who underwent total hip arthroplasty (THA) using S-ROM stem were divided into two groups: secondary acetabulum formaton group (group A) and no secondary acetabulum formaton group (group B). In group A,there were 12 females, 96 males,with an average age of (39.38 ± 11.19) years old. In group B, there were 2 females, 35 males, with an average age of (38.19 ± 10.92) years old. All the patients were evaluated by using Harris Hip Score. Radiographic evaluations were made preoperatively and during follow up. The differences between two groups were compared on dislocation height, canal flare index (CFI), subtrochanteric shortening osteotomy (SSTO) usage, pre- and post-operation Harris scores, complications. The dislocation height for group A was (4.74 ± 1.57) cm, while the dislocation height for group B was (3.12 ± 1.15) cm. Significantly difference was detected between two groups. The CFI for group A was 2.69 ± 0.68, while the CFI for group B was 3.42 ± 0.79, and the significantly difference was detected between two groups. Harris scores were totally improved from 58.18 ± 15.67 preoperatively to 91.20 ± 3.79 post-operatively and the difference was significant. Pre-operative Harris scores was 58.1 ± 15.3 in group A, 58.3 ± 16.9 in group B. Post-operative Harris scores was 91.0 ± 4.1 in group A, 91.0 ± 5.1 in group B. No significant difference was found on Harris scores between A and B preoperatively and post-operatively. Complications of 4 cases peri-prosthesis fracture, 4 cases dislocation and 4 cases nerve injury occur in group A; While only one case dislocation and one case nerve injury occur in group B. No statistical significance was detected. Crowe IV DDH with secondary acetabulum is significantly different from Crowe IV DDH without secondary acetabulum on dislocation height and femoral morphology, which causes the different selections of surgical techniques (SSTO usage or not). These important differences in fundamental parameters indicate the necessity to further divide Crowe IV DDH into IVA and IVB two subtypes.

  3. [Application of health questionnaires for health management in small- and medium-sized enterprises].

    PubMed

    Kishida, K; Saito, M; Hasegawa, T; Aoki, S; Suzuki, S

    1986-01-01

    Two kinds of health questionnaires, the Todai Health Index (THI) and Cumulative Fatigue Index (CFI), were applied as a screening device for health management of workers belonging to small-medium sized enterprises. A total of 495 workers composed of 452 male workers of a glass-bottle manufacturing factory and 43 male workers of a soft-drink bottling factory were the subjects of the present study. It was found that the two kinds of health questionnaires were different from each other and have their own characteristics. Twelve scales of THI were grouped into two, the first consisting of ten scales (SUSY, RESP, EYSK, MOUT, DIGE, IMPU, MENT, DEPR, NERV, and LIFE) and the second consisting of two scales (AGGR and LISC). Nine categories of CFI were grouped into one by using principal factor analysis. It was confirmed that the twelve scale scores of THI obtained at small-medium sized factories differed from those scale scores of a reference group investigated at a large-sized enterprise. It is on the basis of the scales of aggressiveness and lies and also of the scale of mental unstability which characterizes workers, locality, job (clerical or field work), and size of industry (large or small sized) that the difference could be evaluated. Urban life characterized by a life style of staying up late at night and waking up late in the morning has been reflected on the scale of life irregularity. Irregularity of life induced by transformation of working schedule, such as two or three shifts of work and overtime, was also reflected on this scale. Two scales of THI test, i.e., many subjective symptoms and digestive organ complaints, seemed to be the representative scales indicating a close relation between work load and health level. The discriminant score for diagnosis of psychosomatic diseases is considered to be one of the most useful assessments of the individual's health condition. As mentioned above, THI is recommended as a convenient assessment method for health management of workers and for screening individuals or groups requiring health management from the total respondents belonging to small-medium sized enterprises where health administrators or professionals for health services are not available. A combined use of THI and CFI is more effective in evaluating health status of field workers than the independent use of one of these two tests, because the causal relationship between work load and health status cannot be satisfactorily observed, only through THI.

  4. Optimization of camera exposure durations for multi-exposure speckle imaging of the microcirculation

    PubMed Central

    Kazmi, S. M. Shams; Balial, Satyajit; Dunn, Andrew K.

    2014-01-01

    Improved Laser Speckle Contrast Imaging (LSCI) blood flow analyses that incorporate inverse models of the underlying laser-tissue interaction have been used to develop more quantitative implementations of speckle flowmetry such as Multi-Exposure Speckle Imaging (MESI). In this paper, we determine the optimal camera exposure durations required for obtaining flow information with comparable accuracy with the prevailing MESI implementation utilized in recent in vivo rodent studies. A looping leave-one-out (LOO) algorithm was used to identify exposure subsets which were analyzed for accuracy against flows obtained from analysis with the original full exposure set over 9 animals comprising n = 314 regional flow measurements. From the 15 original exposures, 6 exposures were found using the LOO process to provide comparable accuracy, defined as being no more than 10% deviant, with the original flow measurements. The optimal subset of exposures provides a basis set of camera durations for speckle flowmetry studies of the microcirculation and confers a two-fold faster acquisition rate and a 28% reduction in processing time without sacrificing accuracy. Additionally, the optimization process can be used to identify further reductions in the exposure subsets for tailoring imaging over less expansive flow distributions to enable even faster imaging. PMID:25071956

  5. Neural signatures of experimentally induced flow experiences identified in a typical fMRI block design with BOLD imaging

    PubMed Central

    Keller, Johannes; Grön, Georg

    2016-01-01

    Previously, experimentally induced flow experiences have been demonstrated with perfusion imaging during activation blocks of 3 min length to accommodate with the putatively slowly evolving “mood” characteristics of flow. Here, we used functional magnetic resonance imaging (fMRI) in a sample of 23 healthy, male participants to investigate flow in the context of a typical fMRI block design with block lengths as short as 30 s. To induce flow, demands of arithmetic tasks were automatically and continuously adjusted to the individual skill level. Compared against conditions of boredom and overload, experience of flow was evident from individuals’ reported subjective experiences and changes in electrodermal activity. Neural activation was relatively increased during flow, particularly in the anterior insula, inferior frontal gyri, basal ganglia and midbrain. Relative activation decreases during flow were observed in medial prefrontal and posterior cingulate cortex, and in the medial temporal lobe including the amygdala. Present findings suggest that even in the context of comparably short activation blocks flow can be reliably experienced and is associated with changes in neural activation of brain regions previously described. Possible mechanisms of interacting brain regions are outlined, awaiting further investigation which should now be possible given the greater temporal resolution compared with previous perfusion imaging. PMID:26508774

  6. Optofluidic bioimaging platform for quantitative phase imaging of lab on a chip devices using digital holographic microscopy.

    PubMed

    Pandiyan, Vimal Prabhu; John, Renu

    2016-01-20

    We propose a versatile 3D phase-imaging microscope platform for real-time imaging of optomicrofluidic devices based on the principle of digital holographic microscopy (DHM). Lab-on-chip microfluidic devices fabricated on transparent polydimethylsiloxane (PDMS) and glass substrates have attained wide popularity in biological sensing applications. However, monitoring, visualization, and characterization of microfluidic devices, microfluidic flows, and the biochemical kinetics happening in these devices is difficult due to the lack of proper techniques for real-time imaging and analysis. The traditional bright-field microscopic techniques fail in imaging applications, as the microfluidic channels and the fluids carrying biological samples are transparent and not visible in bright light. Phase-based microscopy techniques that can image the phase of the microfluidic channel and changes in refractive indices due to the fluids and biological samples present in the channel are ideal for imaging the fluid flow dynamics in a microfluidic channel at high resolutions. This paper demonstrates three-dimensional imaging of a microfluidic device with nanometric depth precisions and high SNR. We demonstrate imaging of microelectrodes of nanometric thickness patterned on glass substrate and the microfluidic channel. Three-dimensional imaging of a transparent PDMS optomicrofluidic channel, fluid flow, and live yeast cell flow in this channel has been demonstrated using DHM. We also quantify the average velocity of fluid flow through the channel. In comparison to any conventional bright-field microscope, the 3D depth information in the images illustrated in this work carry much information about the biological system under observation. The results demonstrated in this paper prove the high potential of DHM in imaging optofluidic devices; detection of pathogens, cells, and bioanalytes on lab-on-chip devices; and in studying microfluidic dynamics in real time based on phase changes.

  7. Electrical Capacitance Volume Tomography for the Packed Bed Reactor ISS Flight Experiment

    NASA Technical Reports Server (NTRS)

    Marashdeh, Qussai; Motil, Brian; Wang, Aining; Liang-Shih, Fan

    2013-01-01

    Fixed packed bed reactors are compact, require minimum power and maintenance to operate, and are highly reliable. These features make this technology a highly desirable unit operation for long duration life support systems in space. NASA is developing an ISS experiment to address this technology with particular focus on water reclamation and air revitalization. Earlier research and development efforts funded by NASA have resulted in two hydrodynamic models which require validation with appropriate instrumentation in an extended microgravity environment. To validate these models, the instantaneous distribution of the gas and liquid phases must be measured.Electrical Capacitance Volume Tomography (ECVT) is a non-invasive imaging technology recently developed for multi-phase flow applications. It is based on distributing flexible capacitance plates on the peripheral of a flow column and collecting real-time measurements of inter-electrode capacitances. Capacitance measurements here are directly related to dielectric constant distribution, a physical property that is also related to material distribution in the imaging domain. Reconstruction algorithms are employed to map volume images of dielectric distribution in the imaging domain, which is in turn related to phase distribution. ECVT is suitable for imaging interacting materials of different dielectric constants, typical in multi-phase flow systems. ECVT is being used extensively for measuring flow variables in various gas-liquid and gas-solid flow systems. Recent application of ECVT include flows in risers and exit regions of circulating fluidized beds, gas-liquid and gas-solid bubble columns, trickle beds, and slurry bubble columns. ECVT is also used to validate flow models and CFD simulations. The technology is uniquely qualified for imaging phase concentrations in packed bed reactors for the ISS flight experiments as it exhibits favorable features of compact size, low profile sensors, high imaging speed, and flexibility to fit around columns of various shapes and sizes. ECVT is also safer than other commonly used imaging modalities as it operates in the range of low frequencies (1 MHz) and does not radiate radioactive energy. In this effort, ECVT is being used to image flow parameters in a packed bed reactor for an ISS flight experiment.

  8. Noninvasive Imaging of the Coronary Vasculature Using Ultrafast Ultrasound.

    PubMed

    Maresca, David; Correia, Mafalda; Villemain, Olivier; Bizé, Alain; Sambin, Lucien; Tanter, Mickael; Ghaleh, Bijan; Pernot, Mathieu

    2017-08-11

    The aim of this study was to investigate the potential of coronary ultrafast Doppler angiography (CUDA), a novel vascular imaging technique based on ultrafast ultrasound, to image noninvasively with high sensitivity the intramyocardial coronary vasculature and quantify the coronary blood flow dynamics. Noninvasive coronary imaging techniques are currently limited to the observation of the epicardial coronary arteries. However, many studies have highlighted the importance of the coronary microcirculation and microvascular disease. CUDA was performed in vivo in open-chest procedures in 9 swine. Ultrafast plane-wave imaging at 2,000 frames/s was combined to an adaptive spatiotemporal filtering to achieve ultrahigh-sensitive imaging of the coronary blood flows. Quantification of the flow change was performed during hyperemia after a 30-s left anterior descending (LAD) artery occlusion followed by reperfusion and was compared to gold standard measurements provided by a flowmeter probe placed at a proximal location on the LAD (n = 5). Coronary flow reserve was assessed during intravenous perfusion of adenosine. Vascular damages were evaluated during a second set of experiments in which the LAD was occluded for 90 min, followed by 150 min of reperfusion to induce myocardial infarction (n = 3). Finally, the transthoracic feasibility of CUDA was assessed on 2 adult and 2 pediatric volunteers. Ultrahigh-sensitive cine loops of venous and arterial intramyocardial blood flows were obtained within 1 cardiac cycle. Quantification of the coronary flow changes during hyperemia was in good agreement with gold standard measurements (r 2  = 0.89), as well as the assessment of coronary flow reserve (2.35 ± 0.65 vs. 2.28 ± 0.84; p = NS). On the infarcted animals, CUDA images revealed the presence of strong hyperemia and the appearance of abnormal coronary vessel structures in the reperfused LAD territory. Finally, the feasibility of transthoracic coronary vasculature imaging was shown on 4 human volunteers. Ultrafast Doppler imaging can map the coronary vasculature with high sensitivity and quantify intramural coronary blood flow changes. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  9. Ultrafast Microfluidic Cellular Imaging by Optical Time-Stretch.

    PubMed

    Lau, Andy K S; Wong, Terence T W; Shum, Ho Cheung; Wong, Kenneth K Y; Tsia, Kevin K

    2016-01-01

    There is an unmet need in biomedicine for measuring a multitude of parameters of individual cells (i.e., high content) in a large population efficiently (i.e., high throughput). This is particularly driven by the emerging interest in bringing Big-Data analysis into this arena, encompassing pathology, drug discovery, rare cancer cell detection, emulsion microdroplet assays, to name a few. This momentum is particularly evident in recent advancements in flow cytometry. They include scaling of the number of measurable colors from the labeled cells and incorporation of imaging capability to access the morphological information of the cells. However, an unspoken predicament appears in the current technologies: higher content comes at the expense of lower throughput, and vice versa. For example, accessing additional spatial information of individual cells, imaging flow cytometers only achieve an imaging throughput ~1000 cells/s, orders of magnitude slower than the non-imaging flow cytometers. In this chapter, we introduce an entirely new imaging platform, namely optical time-stretch microscopy, for ultrahigh speed and high contrast label-free single-cell (in a ultrafast microfluidic flow up to 10 m/s) imaging and analysis with an ultra-fast imaging line-scan rate as high as tens of MHz. Based on this technique, not only morphological information of the individual cells can be obtained in an ultrafast manner, quantitative evaluation of cellular information (e.g., cell volume, mass, refractive index, stiffness, membrane tension) at nanometer scale based on the optical phase is also possible. The technology can also be integrated with conventional fluorescence measurements widely adopted in the non-imaging flow cytometers. Therefore, these two combinatorial and complementary measurement capabilities in long run is an attractive platform for addressing the pressing need for expanding the "parameter space" in high-throughput single-cell analysis. This chapter provides the general guidelines of constructing the optical system for time stretch imaging, fabrication and design of the microfluidic chip for ultrafast fluidic flow, as well as the image acquisition and processing.

  10. Vortical structures of supersonic flow over a delta-wing on a flat plate

    NASA Astrophysics Data System (ADS)

    Wang, D. P.; Xia, Z. X.; Zhao, Y. X.; Wang, Q. H.; Liu, B.

    2013-02-01

    Employing the nanoparticle-based planar laser scattering (NPLS), supersonic flow over a delta-winged vortex generator on a flat plate was experimentally investigated in a supersonic quiet wind tunnel at Ma = 2.68. The fine structures of the flow field, shock waves, separation vortices, wake, and boundary layer transition were observed in the NPLS images. According to the time-correlation of the NPLS images and the measurement results of particle image velocimetry, the structural model of the flow field was improved further, and coherent wake structures were observed, which is of significance theoretically and in engineering application.

  11. Optical flow estimation on image sequences with differently exposed frames

    NASA Astrophysics Data System (ADS)

    Bengtsson, Tomas; McKelvey, Tomas; Lindström, Konstantin

    2015-09-01

    Optical flow (OF) methods are used to estimate dense motion information between consecutive frames in image sequences. In addition to the specific OF estimation method itself, the quality of the input image sequence is of crucial importance to the quality of the resulting flow estimates. For instance, lack of texture in image frames caused by saturation of the camera sensor during exposure can significantly deteriorate the performance. An approach to avoid this negative effect is to use different camera settings when capturing the individual frames. We provide a framework for OF estimation on such sequences that contain differently exposed frames. Information from multiple frames are combined into a total cost functional such that the lack of an active data term for saturated image areas is avoided. Experimental results demonstrate that using alternate camera settings to capture the full dynamic range of an underlying scene can clearly improve the quality of flow estimates. When saturation of image data is significant, the proposed methods show superior performance in terms of lower endpoint errors of the flow vectors compared to a set of baseline methods. Furthermore, we provide some qualitative examples of how and when our method should be used.

  12. Structure-preserving interpolation of temporal and spatial image sequences using an optical flow-based method.

    PubMed

    Ehrhardt, J; Säring, D; Handels, H

    2007-01-01

    Modern tomographic imaging devices enable the acquisition of spatial and temporal image sequences. But, the spatial and temporal resolution of such devices is limited and therefore image interpolation techniques are needed to represent images at a desired level of discretization. This paper presents a method for structure-preserving interpolation between neighboring slices in temporal or spatial image sequences. In a first step, the spatiotemporal velocity field between image slices is determined using an optical flow-based registration method in order to establish spatial correspondence between adjacent slices. An iterative algorithm is applied using the spatial and temporal image derivatives and a spatiotemporal smoothing step. Afterwards, the calculated velocity field is used to generate an interpolated image at the desired time by averaging intensities between corresponding points. Three quantitative measures are defined to evaluate the performance of the interpolation method. The behavior and capability of the algorithm is demonstrated by synthetic images. A population of 17 temporal and spatial image sequences are utilized to compare the optical flow-based interpolation method to linear and shape-based interpolation. The quantitative results show that the optical flow-based method outperforms the linear and shape-based interpolation statistically significantly. The interpolation method presented is able to generate image sequences with appropriate spatial or temporal resolution needed for image comparison, analysis or visualization tasks. Quantitative and qualitative measures extracted from synthetic phantoms and medical image data show that the new method definitely has advantages over linear and shape-based interpolation.

  13. Real-time Image Processing for Microscopy-based Label-free Imaging Flow Cytometry in a Microfluidic Chip.

    PubMed

    Heo, Young Jin; Lee, Donghyeon; Kang, Junsu; Lee, Keondo; Chung, Wan Kyun

    2017-09-14

    Imaging flow cytometry (IFC) is an emerging technology that acquires single-cell images at high-throughput for analysis of a cell population. Rich information that comes from high sensitivity and spatial resolution of a single-cell microscopic image is beneficial for single-cell analysis in various biological applications. In this paper, we present a fast image-processing pipeline (R-MOD: Real-time Moving Object Detector) based on deep learning for high-throughput microscopy-based label-free IFC in a microfluidic chip. The R-MOD pipeline acquires all single-cell images of cells in flow, and identifies the acquired images as a real-time process with minimum hardware that consists of a microscope and a high-speed camera. Experiments show that R-MOD has the fast and reliable accuracy (500 fps and 93.3% mAP), and is expected to be used as a powerful tool for biomedical and clinical applications.

  14. Analysis of the 2006 block-and-ash flow deposits of Merapi Volcano, Java, Indonesia, using high-spatial resolution IKONOS images and complementary ground based observations

    NASA Astrophysics Data System (ADS)

    Thouret, Jean-Claude; Gupta, Avijit; Liew, Soo Chin; Lube, Gert; Cronin, Shane J.; Surono, Dr

    2010-05-01

    On 16 June 2006 an overpass of IKONOS coincided with the emplacement of an active block-and-ash flow fed by a lava dome collapse event at Merapi Volcano (Java, Indonesia). This was the first satellite image recorded for a moving pyroclastic flow. The very high-spatial resolution data displayed the extent and impact of the pyroclastic deposits emplaced during and prior to, the day of image acquisition. This allowed a number of features associated with high-hazard block-and-ash flows emplaced in narrow, deep gorges to be mapped, interpreted and understood. The block-and-ash flow and surge deposits recognized in the Ikonos images include: (1) several channel-confined flow lobes and tongues in the box-shaped valley; (2) thin ash-cloud surge deposit and knocked-down trees in constricted areas on both slopes of the gorge; (3) fan-like over bank deposits on the Gendol-Tlogo interfluves from which flows were re-routed in the Tlogo secondary valley; (4) massive over bank lobes on the right bank from which flows devastated the village of Kaliadem 0.5 km from the main channel, a small part of this flow being re-channeled in the Opak secondary valley. The high-resolution IKONOS images also helped us to identify geomorphic obstacles that enabled flows to ramp and spill out from the sinuous channel, a process called flow avulsion. Importantly, the avulsion redirected flows to unexpected areas away from the main channel. In the case of Merapi we see that the presence of valley fill by previous deposits, bends and man-made dams influence the otherwise valley-guided course of the flows. Sadly, Sabo dams (built to ameliorate the effect of high sediment load streams) can actually cause block-and-ash flows to jump out of their containing channel and advance into sensitive areas. Very-high-spatial resolution satellite images are very useful for mapping and interpreting the distribution of freshly erupted volcanic deposits. IKONOS-type images with 1-m resolution provide opportunities to study and map the meter-scale detail of volcanic deposits. When such high-spatial-resolution satellite remote sensing data are combined with in situ field work, geomorphic analyses can be applied that allow us to more fully understand the dynamics and hazards of eruptions. In the case given here, IKONOS imagery allowed two qualitative hazard assessments for block-and-ash flow activity in drainages around Merapi. Firstly, the interpretation of IKONOS images provides insights in factors that control the propagation of secondary flows as the avulsion of the main flows is driven by longitudinal change in channel capacity due to increased sinuosity in the valley and decreased containment space. Secondly, the sinuosity and obstacles (including Sabo dams) may create over bank flows over adjacent low relief, allowing them to reach unexpectedly vulnerable areas distant from an active dome and away from the volcanically active valleys. Hazard assessment should therefore consider the geometry of secondary channels outside the principal valleys.

  15. Quantification of cell cycle kinetics by EdU (5-ethynyl-2′-deoxyuridine)-coupled-fluorescence-intensity analysis

    PubMed Central

    Cabrita, Marisa; Bekman, Evguenia; Braga, José; Rino, José; Santus, Renè; Filipe, Paulo L.; Sousa, Ana E.; Ferreira, João A.

    2017-01-01

    We propose a novel single-deoxynucleoside-based assay that is easy to perform and provides accurate values for the absolute length (in units of time) of each of the cell cycle stages (G1, S and G2/M). This flow-cytometric assay takes advantage of the excellent stoichiometric properties of azide-fluorochrome detection of DNA substituted with 5-ethynyl-2′-deoxyuridine (EdU). We show that by pulsing cells with EdU for incremental periods of time maximal EdU-coupled fluorescence is reached when pulsing times match the length of S phase. These pulsing times, allowing labelling for a full S phase of a fraction of cells in asynchronous populations, provide accurate values for the absolute length of S phase. We characterized additional, lower intensity signals that allowed quantification of the absolute durations of G1 and G2 phases. Importantly, using this novel assay data on the lengths of G1, S and G2/M phases are obtained in parallel. Therefore, these parameters can be estimated within a time frame that is shorter than a full cell cycle. This method, which we designate as EdU-Coupled Fluorescence Intensity (E-CFI) analysis, was successfully applied to cell types with distinctive cell cycle features and shows excellent agreement with established methodologies for analysis of cell cycle kinetics. PMID:28465489

  16. Magnetic resonance imaging of convection in laser-polarized xenon

    NASA Technical Reports Server (NTRS)

    Mair, R. W.; Tseng, C. H.; Wong, G. P.; Cory, D. G.; Walsworth, R. L.

    2000-01-01

    We demonstrate nuclear magnetic resonance (NMR) imaging of the flow and diffusion of laser-polarized xenon (129Xe) gas undergoing convection above evaporating laser-polarized liquid xenon. The large xenon NMR signal provided by the laser-polarization technique allows more rapid imaging than one can achieve with thermally polarized gas-liquid systems, permitting shorter time-scale events such as rapid gas flow and gas-liquid dynamics to be observed. Two-dimensional velocity-encoded imaging shows convective gas flow above the evaporating liquid xenon, and also permits the measurement of enhanced gas diffusion near regions of large velocity variation.

  17. Three-dimensional real-time imaging of bi-phasic flow through porous media

    NASA Astrophysics Data System (ADS)

    Sharma, Prerna; Aswathi, P.; Sane, Anit; Ghosh, Shankar; Bhattacharya, S.

    2011-11-01

    We present a scanning laser-sheet video imaging technique to image bi-phasic flow in three-dimensional porous media in real time with pore-scale spatial resolution, i.e., 35 μm and 500 μm for directions parallel and perpendicular to the flow, respectively. The technique is illustrated for the case of viscous fingering. Using suitable image processing protocols, both the morphology and the movement of the two-fluid interface, were quantitatively estimated. Furthermore, a macroscopic parameter such as the displacement efficiency obtained from a microscopic (pore-scale) analysis demonstrates the versatility and usefulness of the method.

  18. Background Oriented Schlieren Using Celestial Objects

    NASA Technical Reports Server (NTRS)

    Haering, Edward, A., Jr. (Inventor); Hill, Michael A (Inventor)

    2017-01-01

    The present invention is a system and method of visualizing fluid flow around an object, such as an aircraft or wind turbine, by aligning the object between an imaging system and a celestial object having a speckled background, taking images, and comparing those images to obtain fluid flow visualization.

  19. Dynamic measurements of flowing cells labeled by gold nanoparticles using full-field photothermal interferometric imaging

    NASA Astrophysics Data System (ADS)

    Turko, Nir A.; Roitshtain, Darina; Blum, Omry; Kemper, Björn; Shaked, Natan T.

    2017-06-01

    We present highly dynamic photothermal interferometric phase microscopy for quantitative, selective contrast imaging of live cells during flow. Gold nanoparticles can be biofunctionalized to bind to specific cells, and stimulated for local temperature increase due to plasmon resonance, causing a rapid change of the optical phase. These phase changes can be recorded by interferometric phase microscopy and analyzed to form an image of the binding sites of the nanoparticles in the cells, gaining molecular specificity. Since the nanoparticle excitation frequency might overlap with the sample dynamics frequencies, photothermal phase imaging was performed on stationary or slowly dynamic samples. Furthermore, the computational analysis of the photothermal signals is time consuming. This makes photothermal imaging unsuitable for applications requiring dynamic imaging or real-time analysis, such as analyzing and sorting cells during fast flow. To overcome these drawbacks, we utilized an external interferometric module and developed new algorithms, based on discrete Fourier transform variants, enabling fast analysis of photothermal signals in highly dynamic live cells. Due to the self-interference module, the cells are imaged with and without excitation in video-rate, effectively increasing signal-to-noise ratio. Our approach holds potential for using photothermal cell imaging and depletion in flow cytometry.

  20. Correcting the Relative Bias of Light Obscuration and Flow Imaging Particle Counters.

    PubMed

    Ripple, Dean C; Hu, Zhishang

    2016-03-01

    Industry and regulatory bodies desire more accurate methods for counting and characterizing particles. Measurements of proteinaceous-particle concentrations by light obscuration and flow imaging can differ by factors of ten or more. We propose methods to correct the diameters reported by light obscuration and flow imaging instruments. For light obscuration, diameters were rescaled based on characterization of the refractive index of typical particles and a light scattering model for the extinction efficiency factor. The light obscuration models are applicable for either homogeneous materials (e.g., silicone oil) or for chemically homogeneous, but spatially non-uniform aggregates (e.g., protein aggregates). For flow imaging, the method relied on calibration of the instrument with silica beads suspended in water-glycerol mixtures. These methods were applied to a silicone-oil droplet suspension and four particle suspensions containing particles produced from heat stressed and agitated human serum albumin, agitated polyclonal immunoglobulin, and abraded ethylene tetrafluoroethylene polymer. All suspensions were measured by two flow imaging and one light obscuration apparatus. Prior to correction, results from the three instruments disagreed by a factor ranging from 3.1 to 48 in particle concentration over the size range from 2 to 20 μm. Bias corrections reduced the disagreement from an average factor of 14 down to an average factor of 1.5. The methods presented show promise in reducing the relative bias between light obscuration and flow imaging.

  1. A highly accurate symmetric optical flow based high-dimensional nonlinear spatial normalization of brain images.

    PubMed

    Wen, Ying; Hou, Lili; He, Lianghua; Peterson, Bradley S; Xu, Dongrong

    2015-05-01

    Spatial normalization plays a key role in voxel-based analyses of brain images. We propose a highly accurate algorithm for high-dimensional spatial normalization of brain images based on the technique of symmetric optical flow. We first construct a three dimension optical model with the consistency assumption of intensity and consistency of the gradient of intensity under a constraint of discontinuity-preserving spatio-temporal smoothness. Then, an efficient inverse consistency optical flow is proposed with aims of higher registration accuracy, where the flow is naturally symmetric. By employing a hierarchical strategy ranging from coarse to fine scales of resolution and a method of Euler-Lagrange numerical analysis, our algorithm is capable of registering brain images data. Experiments using both simulated and real datasets demonstrated that the accuracy of our algorithm is not only better than that of those traditional optical flow algorithms, but also comparable to other registration methods used extensively in the medical imaging community. Moreover, our registration algorithm is fully automated, requiring a very limited number of parameters and no manual intervention. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Velocity of mist droplets and suspending gas imaged separately

    NASA Astrophysics Data System (ADS)

    Kuethe, Dean O.; McBride, Amber; Altobelli, Stephen A.

    2012-03-01

    Nuclear Magnetic Resonance Images (MRIs) of the velocity of water droplets and velocity of the suspending gas, hexafluoroethane, are presented for a vertical and horizontal mist pipe flow. In the vertical flow, the upward velocity of the droplets is clearly slower than the upward velocity of the gas. The average droplet size calculated from the average falling velocity in the upward flow is larger than the average droplet size of mist drawn from the top of the pipe measured with a multi-stage aerosol impactor. Vertical flow concentrates larger particles because they have a longer transit time through the pipe. In the horizontal flow there is a gravity-driven circulation with high-velocity mist in the lower portion of the pipe and low-velocity gas in the upper portion. MRI has the advantages that it can image both phases and that it is unperturbed by optical opacity. A drawback is that the droplet phase of mist is difficult to image because of low average spin density and because the signal from water coalesced on the pipe walls is high. To our knowledge these are the first NMR images of mist.

  3. Electron-Beam Diagnostic Methods for Hypersonic Flow Diagnostics

    NASA Technical Reports Server (NTRS)

    1994-01-01

    The purpose of this work was the evaluation of the use of electron-bean fluorescence for flow measurements during hypersonic flight. Both analytical and numerical models were developed in this investigation to evaluate quantitatively flow field imaging concepts based upon the electron beam fluorescence technique for use in flight research and wind tunnel applications. Specific models were developed for: (1) fluorescence excitation/emission for nitrogen, (2) rotational fluorescence spectrum for nitrogen, (3) single and multiple scattering of electrons in a variable density medium, (4) spatial and spectral distribution of fluorescence, (5) measurement of rotational temperature and density, (6) optical filter design for fluorescence imaging, and (7) temperature accuracy and signal acquisition time requirements. Application of these models to a typical hypersonic wind tunnel flow is presented. In particular, the capability of simulating the fluorescence resulting from electron impact ionization in a variable density nitrogen or air flow provides the capability to evaluate the design of imaging instruments for flow field mapping. The result of this analysis is a recommendation that quantitative measurements of hypersonic flow fields using electron-bean fluorescence is a tractable method with electron beam energies of 100 keV. With lower electron energies, electron scattering increases with significant beam divergence which makes quantitative imaging difficult. The potential application of the analytical and numerical models developed in this work is in the design of a flow field imaging instrument for use in hypersonic wind tunnels or onboard a flight research vehicle.

  4. PARTICLE IMAGE VELOCIMETRY MEASUREMENTS IN A REPRESENTATIVE GAS-COOLED PRISMATIC REACTOR CORE MODEL: FLOW IN THE COOLANT CHANNELS AND INTERSTITIAL BYPASS GAPS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thomas E. Conder; Richard Skifton; Ralph Budwig

    Core bypass flow is one of the key issues with the prismatic Gas Turbine-Modular Helium Reactor, and it refers to the coolant that navigates through the interstitial, non-cooling passages between the graphite fuel blocks instead of traveling through the designated coolant channels. To determine the bypass flow, a double scale representative model was manufactured and installed in the Matched Index-of-Refraction flow facility; after which, stereo Particle Image Velocimetry (PIV) was employed to measure the flow field within. PIV images were analyzed to produce vector maps, and flow rates were calculated by numerically integrating over the velocity field. It was foundmore » that the bypass flow varied between 6.9-15.8% for channel Reynolds numbers of 1,746 and 4,618. The results were compared to computational fluid dynamic (CFD) pre-test simulations. When compared to these pretest calculations, the CFD analysis appeared to under predict the flow through the gap.« less

  5. A far-infrared spatial/spectral Fourier interferometry laboratory-based testbed instrument

    NASA Astrophysics Data System (ADS)

    Spencer, Locke D.; Naylor, David A.; Scott, Jeremy P.; Weiler, Vince F.; MacCrimmon, Roderick K.; Sitwell, Geoffrey R. H.; Ade, Peter A. R.

    2016-07-01

    We describe the current status, including preliminary design, characterization efforts, and recent progress, in the development of a spatial/spectral double Fourier laboratory-based interferometer testbed instrument within the Astronomical Instrumentation Group (AIG) laboratories at the University of Lethbridge, Canada (UL). Supported by CRC, CFI, and NSERC grants, this instrument development will provide laboratory demonstration of spatial-spectral interferometry with a concentration of furthering progress in areas including the development of spatial/spectral interferometry observation, data processing, characterization, and analysis techniques in the Far-Infrared (FIR) region of the electromagnetic spectrum.

  6. Proceedings of the 8th Matched-Field Processing Workshop, 12-14 June 1996,

    DTIC Science & Technology

    1996-10-01

    and M. B. Porter Active Matched-Field Tracking (AMFT) ............................................ 29 Homer Bucker Matched-Field Track - Before - Detect (TBD...CD I- z - .4 U) - U :T 0 4,) 0j w CfI -ID 0 ci) CD) CD CD o0 0 C 0D CD 0C o 00 Matched-Field Track - Before - Detect (TBD) Processing using SWellEX...surfaces are used in a source-track search. Track - before - detect (TBD) processing makes use of this technique to extract source track information so that the

  7. Wind-Tunnel Tests of Several Arrangements of External Auxiliary Fuel Tanks on a Fighter-Type Airplane

    DTIC Science & Technology

    1942-08-01

    vinfi tanks of lorg plane. Mcdjl ta:ik tiona ä.oignod to attached to n typi this lr..-estimation 350-grllcn fuvl ».;etion...of ISO-gilo showod tho lci.st effect o of the -lrpl’-no yith .*. ch lift-dr.-g rr.tlo iron 3.0 Tank -\\ n .-,l..a ci...and alle Th; eircul- n nr.u 30C-|F;I11 n tue noroiynrj iaifu In tho nc: to 4.8 percent >*.nd vertical d s, vlthin reas f 3S0

  8. Imaging nanoparticle flow using magneto-motive optical Doppler tomography.

    PubMed

    Kim, Jeehyun; Oh, Junghwan; Milner, Thomas E; Nelson, J Stuart

    2007-01-24

    We introduce a novel approach for imaging solutions of superparamagnetic iron oxide (SPIO) nanoparticles using magneto-motive optical Doppler tomography (MM-ODT). MM-ODT combines an externally applied temporally oscillating high-strength magnetic field with ODT to detect nanoparticles flowing through a microfluidic channel. A solenoid with a cone-shaped ferrite core extensively increased the magnetic field strength (B(max) = 1 T, [Formula: see text]) at the tip of the core and also focused the magnetic field in microfluidic channels containing nanoparticle solutions. Nanoparticle contrast was demonstrated in a microfluidic channel filled with an SPIO solution by imaging the Doppler frequency shift which was observed independently of the nanoparticle flow rate and direction. Results suggest that MM-ODT may be applied to image Doppler shift of SPIO nanoparticles in microfluidic flows with high contrast.

  9. Simultaneous narrowband ultrasonic strain-flow imaging

    NASA Astrophysics Data System (ADS)

    Tsou, Jean K.; Mai, Jerome J.; Lupotti, Fermin A.; Insana, Michael F.

    2004-04-01

    We are summarizing new research aimed at forming spatially and temporally registered combinations of strain and color-flow images using echo data recorded from a commercial ultrasound system. Applications include diagnosis of vascular diseases and tumor malignancies. The challenge is to meet the diverse needs of each measurement. The approach is to first apply eigenfilters that separate echo components from moving tissues and blood flow, and then estimate blood velocity and tissue displacement from the filtered-IQ-signal phase modulations. At the cost of a lower acquisition frame rate, we find the autocorrelation strain estimator yields higher resolution strain estimate than the cross-correlator since estimates are made from ensembles at a single point in space. The technique is applied to in vivo carotid imaging, to demonstrate the sensitivity for strain-flow vascular imaging.

  10. Flow visualization V; Proceedings of the 5th International Symposium, Prague, Czechoslovakia, Aug. 21-25, 1989

    NASA Astrophysics Data System (ADS)

    Reznicek, R.

    The present conference on flow visualization encompasses methods exploiting tracing particles, surface tracing methods, methods exploiting the effects of streaming fluid on passing radiation/field, computer-aided flow visualization, and applications to fluid mechanics, aerodynamics, flow devices, shock tubes, and heat/mass transfer. Specific issues include visualizing velocity distribution by stereo photography, dark-field Fourier quasiinterferometry, speckle tomography of an open flame, a fast eye for real-time image analysis, and velocity-field determination based on flow-image analysis. Also addressed are flows around rectangular prisms with oscillating flaps at the leading edges, the tomography of aerodynamic objects, the vapor-screen technique applied to a delta-wing aircraft, flash-lamp planar imaging, IR-thermography applications in convective heat transfer, and the visualization of marangoni effects in evaporating sessile drops.

  11. Highly accelerated intracranial 4D flow MRI: evaluation of healthy volunteers and patients with intracranial aneurysms.

    PubMed

    Liu, Jing; Koskas, Louise; Faraji, Farshid; Kao, Evan; Wang, Yan; Haraldsson, Henrik; Kefayati, Sarah; Zhu, Chengcheng; Ahn, Sinyeob; Laub, Gerhard; Saloner, David

    2018-04-01

    To evaluate an accelerated 4D flow MRI method that provides high temporal resolution in a clinically feasible acquisition time for intracranial velocity imaging. Accelerated 4D flow MRI was developed by using a pseudo-random variable-density Cartesian undersampling strategy (CIRCUS) with the combination of k-t, parallel imaging and compressed sensing image reconstruction techniques (k-t SPARSE-SENSE). Four-dimensional flow data were acquired on five healthy volunteers and eight patients with intracranial aneurysms using CIRCUS (acceleration factor of R = 4, termed CIRCUS4) and GRAPPA (R = 2, termed GRAPPA2) as the reference method. Images with three times higher temporal resolution (R = 12, CIRCUS12) were also reconstructed from the same acquisition as CIRCUS4. Qualitative and quantitative image assessment was performed on the images acquired with different methods, and complex flow patterns in the aneurysms were identified and compared. Four-dimensional flow MRI with CIRCUS was achieved in 5 min and allowed further improved temporal resolution of <30 ms. Volunteer studies showed similar qualitative and quantitative evaluation obtained with the proposed approach compared to the reference (overall image scores: GRAPPA2 3.2 ± 0.6; CIRCUS4 3.1 ± 0.7; CIRCUS12 3.3 ± 0.4; difference of the peak velocities: -3.83 ± 7.72 cm/s between CIRCUS4 and GRAPPA2, -1.72 ± 8.41 cm/s between CIRCUS12 and GRAPPA2). In patients with intracranial aneurysms, the higher temporal resolution improved capturing of the flow features in intracranial aneurysms (pathline visualization scores: GRAPPA2 2.2 ± 0.2; CIRCUS4 2.5 ± 0.5; CIRCUS12 2.7 ± 0.6). The proposed rapid 4D flow MRI with a high temporal resolution is a promising tool for evaluating intracranial aneurysms in a clinically feasible acquisition time.

  12. Infrared Imaging of Nitric Oxide-Mediated Blood Flow in Human Sickle Cell Disease

    PubMed Central

    Gorbach, Alexander M.; Ackerman, Hans C.; Liu, Wei-Min; Meyer, Joseph M.; Littel, Patricia L.; Seamon, Catherine; Footman, Eleni; Chi, Amy; Zorca, Suzana; Krajewski, Megan L.; Cuttica, Michael J.; Machado, Roberto F.; Cannon, Richard O.; Kato, Gregory J.

    2012-01-01

    Vascular dysfunction is an important pathophysiologic manifestation of sickle cell disease (SCD), a condition that increases risk of pulmonary hypertension and stroke. We hypothesized that infrared (IR) imaging would detect changes in cutaneous blood flow reflective of vascular function. We performed IR imaging and conventional strain gauge plethysmography in twenty-five adults with SCD at baseline and during intra-arterial infusions of an endothelium-dependent vasodilator acetylcholine (ACh), an endothelium-independent vasodilator sodium nitroprusside (SNP), and a NOS inhibitor L-NMMA. Skin temperature measured by IR imaging increased in a dose-dependent manner to graded infusions of ACh (+1.1° C, p < 0.0001) and SNP (+0.9° C, p < 0.0001), and correlated with dose-dependent increases in forearm blood flow (ACh: +19.9 mL/min/100mL, p < 0.0001; rs = 0.57, p = 0.003; SNP: +8.6 mL/min/100mL, p < 0.0001; r = 0.70, p = 0.0002). Although IR measurement of skin temperature accurately reflected agonist-induced increases in blood flow, it was less sensitive to decreases in blood flow caused by NOS inhibition. Baseline forearm skin temperature measured by IR imaging correlated significantly with baseline forearm blood flow (31.8±0.2° C, 6.0±0.4 mL/min/100mL; r = 0.58, p = 0.003), and appeared to represent a novel biomarker of vascular function. It predicted a blunted blood flow response to SNP (r = −0.61, p = 0.002), and was independently associated with a marker of pulmonary artery pressure, as well as hemoglobin level, diastolic blood pressure, homocysteine, and cholesterol (R2 = 0.84, p < 0.0001 for the model). IR imaging of agonist-stimulated cutaneous blood flow represents a less cumbersome alternative to plethysmography methodology. Measurement of baseline skin temperature by IR imaging may be a useful new marker of vascular risk in adults with SCD. PMID:22784510

  13. Method for in-vivo synthetic aperture B-flow imaging

    NASA Astrophysics Data System (ADS)

    Jensen, Jorgen A.

    2004-04-01

    B-flow techniques introduced in commercial scanners have been useful is visualizing places of flow. The method is relatively independent of flow angle and can give a good perception of vessel location and turbulence. This paper introduces a technique for making a synthetic aperture B-flow system. Data is acquired over a number of pulse emissions, where a set of elements synthesizes a spherical wave and the received signal on all elements are acquired. The sequence is repeated and a full new image can always be formed from the last set of emissions, thus making the frame rate very high. The data is continuously available at all places in the image and any kind of echo canceling filter can therefore be used without the usual initialization problems. The B-flow images are then formed by displaying the gray level image after echo canceling. A fast moving scatterer will give a bright echo and slower moving scatterers will yield a dark echo. The approach is demonstrated through in-vivo images. A 128 elements 7 MHz probe with lambda pitch is used together with the RASMUS experimental scanner. Eleven elements are used per emission and the eight emissions are spread evenly over the 128 elements of the array. The signal received by the 64 elements closets to the emission are sampled at 40 MHz and 12 bits at a pulse repetition frequency of 3 kHz. A full second of data is acquired from a healthy 29 years old male volunteer from the carotid artery. The data is beamformed, combined, and echo canceled off-line. High-pass filters designed by the Remez exchange algorithm, have been used for the B-flow processing. The image is displayed after each set of emissions yielding 375 frames per second. Both the flow in the carotid artery and the jugular vein can be seen along with an indication of the acceleration and spatial variation of the velocity.

  14. Development of a multi-exposure speckle imaging for mice brain imaging

    NASA Astrophysics Data System (ADS)

    Soleimanzad, Haleh; Gurden, Hirac; Pain, Frédéric

    2017-02-01

    In the last decade, Laser Speckle Contrast Imaging (LSCI) has been proposed and validated for imaging cerebral blood flow at the rodent brain surface in vivo. The technique relies on the calculation of the spatial speckle contrast, which is related to the velocity of scatterers (red blood cells). The implementation of the technique requires a partial craniotomy so that the brain tissues of interest can be illuminated with a laser diode. However, the studies of changes in the microcirculation during disease progression or treatment require longitudinal studies (i.e. imaging is done repeatedly over weeks or even months). Practically, the less invasive way to obtain such data is to image through the thinned skull without a craniotomy. However the presence of static scatterers (skull) will affect the speckle calculation and produce a bias in the estimation of the microcirculation changes. An extension to LSCI, termed Multi-Exposure Speckle Imaging (MESI) was proposed and validated a few years ago that address these limitations. It relies on a model of the speckle contrast as a function of the exposure time and the proportion of static scatterers. Here, we used MESI with the aim of repeatedly imaging the olfactory bulb of mice models of obesity. First, we have developed a MESI set up which was characterized on microfluidic flow phantoms with different flow-rates and channel diameters to simulate blood flow in animal model characteristics. Second, we show that MESI can discriminate flows in the presence of static scatterers and it can measure flow changes consistently. Finally we provide an in vivo validation of the technique in mice with and without a craniotomy.

  15. An Automated Measurement of Ciliary Beating Frequency using a Combined Optical Flow and Peak Detection.

    PubMed

    Kim, Woojae; Han, Tae Hwa; Kim, Hyun Jun; Park, Man Young; Kim, Ku Sang; Park, Rae Woong

    2011-06-01

    The mucociliary transport system is a major defense mechanism of the respiratory tract. The performance of mucous transportation in the nasal cavity can be represented by a ciliary beating frequency (CBF). This study proposes a novel method to measure CBF by using optical flow. To obtain objective estimates of CBF from video images, an automated computer-based image processing technique is developed. This study proposes a new method based on optical flow for image processing and peak detection for signal processing. We compare the measuring accuracy of the method in various combinations of image processing (optical flow versus difference image) and signal processing (fast Fourier transform [FFT] vs. peak detection [PD]). The digital high-speed video method with a manual count of CBF in slow motion video play, is the gold-standard in CBF measurement. We obtained a total of fifty recorded ciliated sinonasal epithelium images to measure CBF from the Department of Otolaryngology. The ciliated sinonasal epithelium images were recorded at 50-100 frames per second using a charge coupled device camera with an inverted microscope at a magnification of ×1,000. The mean square errors and variance for each method were 1.24, 0.84 Hz; 11.8, 2.63 Hz; 3.22, 1.46 Hz; and 3.82, 1.53 Hz for optical flow (OF) + PD, OF + FFT, difference image [DI] + PD, and DI + FFT, respectively. Of the four methods, PD using optical flow showed the best performance for measuring the CBF of nasal mucosa. The proposed method was able to measure CBF more objectively and efficiently than what is currently possible.

  16. Measurement of renal blood flow by phase-contrast magnetic resonance imaging during septic acute kidney injury: a pilot investigation.

    PubMed

    Prowle, John R; Molan, Maurice P; Hornsey, Emma; Bellomo, Rinaldo

    2012-06-01

    In septic patients, decreased renal perfusion is considered to play a major role in the pathogenesis of acute kidney injury. However, the accurate measurement of renal blood flow in such patients is problematic and invasive. We sought to overcome such obstacles by measuring renal blood flow in septic patients with acute kidney injury using cine phase-contrast magnetic resonance imaging. Pilot observational study. University-affiliated general adult intensive care unit. Ten adult patients with established septic acute kidney injury and 11 normal volunteers. Cine phase-contrast magnetic resonance imaging measurement of renal blood flow and cardiac output. The median age of the study patients was 62.5 yrs and eight were male. At the time of magnetic resonance imaging, eight patients were mechanically ventilated, nine were on continuous hemofiltration, and five required vasopressors. Cine phase-contrast magnetic resonance imaging examinations were carried out without complication. Median renal blood flow was 482 mL/min (range 335-1137) in septic acute kidney injury and 1260 mL/min (range 791-1750) in healthy controls (p = .003). Renal blood flow indexed to body surface area was 244 mL/min/m2 (range 165-662) in septic acute kidney injury and 525 mL/min/m2 (range 438-869) in controls (p = .004). In patients with septic acute kidney injury, median cardiac index was 3.5 L/min/m2 (range 1.6-8.7), and median renal fraction of cardiac output was only 7.1% (range 4.4-10.8). There was no rank correlation between renal blood flow index and creatinine clearance in patients with septic acute kidney injury (r = .26, p = .45). Cine phase-contrast magnetic resonance imaging can be used to noninvasively and safely assess renal perfusion during critical illness in man. Near-simultaneous accurate measurement of cardiac output enables organ blood flow to be assessed in the context of the global circulation. Renal blood flow seems consistently reduced as a fraction of cardiac output in established septic acute kidney injury. Cine phase-contrast magnetic resonance imaging may be a valuable tool to further investigate renal blood flow and the effects of therapies on renal blood flow in critical illness.

  17. Modern Diagnostic Techniques for the Assessment of Ocular Blood Flow in Myopia: Current State of Knowledge.

    PubMed

    Grudzińska, Ewa; Modrzejewska, Monika

    2018-01-01

    Myopia is the most common refractive error and the subject of interest of various studies assessing ocular blood flow. Increasing refractive error and axial elongation of the eye result in the stretching and thinning of the scleral, choroid, and retinal tissues and the decrease in retinal vessel diameter, disturbing ocular blood flow. Local and systemic factors known to change ocular blood flow include glaucoma, medications and fluctuations in intraocular pressure, and metabolic parameters. Techniques and tools assessing ocular blood flow include, among others, laser Doppler flowmetry (LDF), retinal function imager (RFI), laser speckle contrast imaging (LSCI), magnetic resonance imaging (MRI), optical coherence tomography angiography (OCTA), pulsatile ocular blood flowmeter (POBF), fundus pulsation amplitude (FPA), colour Doppler imaging (CDI), and Doppler optical coherence tomography (DOCT). Many researchers consistently reported lower blood flow parameters in myopic eyes regardless of the used diagnostic method. It is unclear whether this is a primary change that causes secondary thinning of ocular tissues or quite the opposite; that is, the mechanical stretching of the eye wall reduces its thickness and causes a secondary lower demand of tissues for oxygen. This paper presents a review of studies assessing ocular blood flow in myopes.

  18. Locating an imaging radar in Canada for identifying spaceborne objects

    NASA Astrophysics Data System (ADS)

    Schick, William G.

    1992-12-01

    This research presents a study of the maximal coverage p-median facility location problem as applied to the location of an imaging radar in Canada for imaging spaceborne objects. The classical mathematical formulation of the maximal coverage p-median problem is converted into network-flow with side constraint formulations that are developed using a scaled down version of the imaging radar location problem. Two types of network-flow with side constraint formulations are developed: a network using side constraints that simulates the gains in a generalized network; and a network resembling a multi-commodity flow problem that uses side constraints to force flow along identical arcs. These small formulations are expanded to encompass a case study using 12 candidate radar sites, and 48 satellites divided into three states. SAS/OR PROC NETFLOW was used to solve the network-flow with side constraint formulations. The case study show that potential for both formulations, although the simulated gains formulation encountered singular matrix computational difficulties as a result of the very organized nature of its side constraint matrix. The multi-commodity flow formulation, when combined with equi-distribution of flow constraints, provided solutions for various values of p, the number of facilities to be selected.

  19. Flow Around a Crater on Ceres

    NASA Image and Video Library

    2017-05-02

    Ceres surface shows evidence for different types of flows that indicate the presence of ice in the regolith. One type of flow encircles the large impact crater at right in this image taken by NASA Dawn spacecraft. One type of flow encircles the large impact crater at right in this image. Scientists see features in this flow that indicate a low degree of internal friction within its material, meaning it was able to flow easily and far from its source. This could be due to the incorporation of a significant amount of liquid water or water vapor into the ejecta blanket. This flow also shows a large ridge along its edge (seen most clearly just to the left of the large crater). These features are commonly associated with flows on Mars called "fluidized ejecta blankets." This feature is located southwest of Kerwan crater at 40 degrees south latitude, 109 degrees east longitude. This is in the vicinity of the latitudes where Dawn's gamma ray and neutron spectrometer (GRaND) instrument sensed the presence of ice in the first meter of Ceres' regolith. The image was taken on August, 7, 2016 from an altitude of about 240 miles (390 kilometers) above Ceres. The image resolution is about 120 feet (35 meters) per pixel. https://photojournal.jpl.nasa.gov/catalog/PIA21404

  20. [Clinical evaluation of regurgitant blood flow by rapid cine magnetic resonance imaging in patients with valvular heart disease].

    PubMed

    Onishi, S; Fukui, S; Atsumi, C; Morita, R; Fujii, K; Kusuoka, H; Kitabatake, A; Kamada, T; Takizawa, O

    1989-06-01

    The clinical usefulness of magnetic resonance imaging (MRI) for evaluating regurgitant blood flow in patients with valvular heart disease was studied. The study subjects comprised three healthy volunteers and nine patients with valvular heart disease (aortic regurgitation 3, mitral regurgitation 2, tricuspid regurgitation 2, and pulmonary regurgitation 2). Five were men and seven were women, ranging in age from 31 to 85 years. Valvular heart disease was diagnosed by two-dimensional Doppler echocardiography. MRI was performed using a 1.5 tesla super-conductive magnet system (MAGNETOM, Siemens AG). A rapid MRI technique (fast low-angle shot [FLASH], flip angle = 30 degrees, TR = 65-90 msec, TE = 10-38 msec) was used to generate 11 frames throughout one cardiac cycle in the transaxial, coronal and oblique planes. These sequential frames were displayed in cine mode on a CRT. 1. Intracavitary blood was imaged as a high signal intensity on gradient echo images, while surrounding cardiac structures had somewhat lower signal intensities. 2. In healthy volunteers, systolic ejection blood flow from the left ventricle was observed on coronal images in the cine mode display. The influx of atrial blood into the left and right ventricles was also clearly observed on transaxial cine images. 3. Aortic regurgitant flow was observed as areas of no signal intensity within the left ventricular cavity during diastole on coronal images. 4. Mitral and tricuspid regurgitations were observed within the left and right atria, respectively, as areas of no signal intensity on transaxial images. The extent of regurgitant flow was determined in the vertical long-axis plane, equivalent to the right anterior oblique projection. 5. The vertical oblique scan was suitable for detecting pulmonary regurgitant flow. These results indicate that the rapid cine MRI technique is a useful tool for noninvasively determining regurgitant blood flow in patients with various valvular heart diseases.

  1. Optical flows method for lightweight agile remote sensor design and instrumentation

    NASA Astrophysics Data System (ADS)

    Wang, Chong; Xing, Fei; Wang, Hongjian; You, Zheng

    2013-08-01

    Lightweight agile remote sensors have become one type of the most important payloads and were widely utilized in space reconnaissance and resource survey. These imaging sensors are designed to obtain the high spatial, temporary and spectral resolution imageries. Key techniques in instrumentation include flexible maneuvering, advanced imaging control algorithms and integrative measuring techniques, which are closely correlative or even acting as the bottle-necks for each other. Therefore, mutual restrictive problems must be solved and optimized. Optical flow is the critical model which to be fully represented in the information transferring as well as radiation energy flowing in dynamic imaging. For agile sensors, especially with wide-field-of view, imaging optical flows may distort and deviate seriously when they perform large angle attitude maneuvering imaging. The phenomena are mainly attributed to the geometrical characteristics of the three-dimensional earth surface as well as the coupled effects due to the complicated relative motion between the sensor and scene. Under this circumstance, velocity fields distribute nonlinearly, the imageries may badly be smeared or probably the geometrical structures are changed since the image velocity matching errors are not having been eliminated perfectly. In this paper, precise imaging optical flow model is established for agile remote sensors, for which optical flows evolving is factorized by two forms, which respectively due to translational movement and image shape changing. Moreover, base on that, agile remote sensors instrumentation was investigated. The main techniques which concern optical flow modeling include integrative design with lightweight star sensors along with micro inertial measurement units and corresponding data fusion, the assemblies of focal plane layout and control, imageries post processing for agile remote sensors etc. Some experiments show that the optical analyzing method is effective to eliminate the limitations for the performance indexes, and succeeded to be applied for integrative system design. Finally, a principle prototype of agile remote sensor designed by the method is discussed.

  2. Methods to Enhance Laser Speckle Imaging of High-Flow and Low-Flow Vasculature

    PubMed Central

    Choi, Bernard; Ringold, Tyson L.; Kim, Jeehyun

    2012-01-01

    The objective of this paper is to present two methods to extend the response range of laser speckle imaging (LSI). We report on the use of two methods (image exposure time control and magnetomotive actuation of exogenous contrast agents) to enhance characterization of high- and low-flow vasculature, respectively. With an exposure time of 10 and 0.01 ms, the linear response range extended to 10 and 280 mm/s, respectively. With application of an AC magnetic field to a solution of stagnant SPIO particles, an apparent increase of ~3× in speckle flow index was induced. PMID:19964103

  3. Multiscale properties of weighted total variation flow with applications to denoising and registration.

    PubMed

    Athavale, Prashant; Xu, Robert; Radau, Perry; Nachman, Adrian; Wright, Graham A

    2015-07-01

    Images consist of structures of varying scales: large scale structures such as flat regions, and small scale structures such as noise, textures, and rapidly oscillatory patterns. In the hierarchical (BV, L(2)) image decomposition, Tadmor, et al. (2004) start with extracting coarse scale structures from a given image, and successively extract finer structures from the residuals in each step of the iterative decomposition. We propose to begin instead by extracting the finest structures from the given image and then proceed to extract increasingly coarser structures. In most images, noise could be considered as a fine scale structure. Thus, starting the image decomposition with finer scales, rather than large scales, leads to fast denoising. We note that our approach turns out to be equivalent to the nonstationary regularization in Scherzer and Weickert (2000). The continuous limit of this procedure leads to a time-scaled version of total variation flow. Motivated by specific clinical applications, we introduce an image depending weight in the regularization functional, and study the corresponding weighted TV flow. We show that the edge-preserving property of the multiscale representation of an input image obtained with the weighted TV flow can be enhanced and localized by appropriate choice of the weight. We use this in developing an efficient and edge-preserving denoising algorithm with control on speed and localization properties. We examine analytical properties of the weighted TV flow that give precise information about the denoising speed and the rate of change of energy of the images. An additional contribution of the paper is to use the images obtained at different scales for robust multiscale registration. We show that the inherently multiscale nature of the weighted TV flow improved performance for registration of noisy cardiac MRI images, compared to other methods such as bilateral or Gaussian filtering. A clinical application of the multiscale registration algorithm is also demonstrated for aligning viability assessment magnetic resonance (MR) images from 8 patients with previous myocardial infarctions. Copyright © 2015. Published by Elsevier B.V.

  4. Application of Thinned-Skull Cranial Window to Mouse Cerebral Blood Flow Imaging Using Optical Microangiography

    PubMed Central

    Wang, Ruikang K.

    2014-01-01

    In vivo imaging of mouse brain vasculature typically requires applying skull window opening techniques: open-skull cranial window or thinned-skull cranial window. We report non-invasive 3D in vivo cerebral blood flow imaging of C57/BL mouse by the use of ultra-high sensitive optical microangiography (UHS-OMAG) and Doppler optical microangiography (DOMAG) techniques to evaluate two cranial window types based on their procedures and ability to visualize surface pial vessel dynamics. Application of the thinned-skull technique is found to be effective in achieving high quality images for pial vessels for short-term imaging, and has advantages over the open-skull technique in available imaging area, surgical efficiency, and cerebral environment preservation. In summary, thinned-skull cranial window serves as a promising tool in studying hemodynamics in pial microvasculature using OMAG or other OCT blood flow imaging modalities. PMID:25426632

  5. Visualizing and measuring flow in shale matrix using in situ synchrotron X-ray microtomography

    NASA Astrophysics Data System (ADS)

    Kohli, A. H.; Kiss, A. M.; Kovscek, A. R.; Bargar, J.

    2017-12-01

    Natural gas production via hydraulic fracturing of shale has proliferated on a global scale, yet recovery factors remain low because production strategies are not based on the physics of flow in shale reservoirs. In particular, the physical mechanisms and time scales of depletion from the matrix into the simulated fracture network are not well understood, limiting the potential to optimize operations and reduce environmental impacts. Studying matrix flow is challenging because shale is heterogeneous and has porosity from the μm- to nm-scale. Characterizing nm-scale flow paths requires electron microscopy but the limited field of view does not capture the connectivity and heterogeneity observed at the mm-scale. Therefore, pore-scale models must link to larger volumes to simulate flow on the reservoir-scale. Upscaled models must honor the physics of flow, but at present there is a gap between cm-scale experiments and μm-scale simulations based on ex situ image data. To address this gap, we developed a synchrotron X-ray microscope with an in situ cell to simultaneously visualize and measure flow. We perform coupled flow and microtomography experiments on mm-scale samples from the Barnett, Eagle Ford and Marcellus reservoirs. We measure permeability at various pressures via the pulse-decay method to quantify effective stress dependence and the relative contributions of advective and diffusive mechanisms. Images at each pressure step document how microfractures, interparticle pores, and organic matter change with effective stress. Linking changes in the pore network to flow measurements motivates a physical model for depletion. To directly visualize flow, we measure imbibition rates using inert, high atomic number gases and image periodically with monochromatic beam. By imaging above/below X-ray adsorption edges, we magnify the signal of gas saturation in μm-scale porosity and nm-scale, sub-voxel features. Comparing vacuumed and saturated states yields image-based measurements of the distribution and time scales of imbibition. We also characterize nm-scale structure via focused ion beam tomography to quantify sub-voxel porosity and connectivity. The multi-scale image and flow data is used to develop a framework to upscale and benchmark pore-scale models.

  6. Flow visualization for investigating stator losses in a multistage axial compressor

    NASA Astrophysics Data System (ADS)

    Smith, Natalie R.; Key, Nicole L.

    2015-05-01

    The methodology and implementation of a powder-paint-based flow visualization technique along with the illuminated flow physics are presented in detail for application in a three-stage axial compressor. While flow visualization often accompanies detailed studies, the turbomachinery literature lacks a comprehensive study which both utilizes flow visualization to interrupt the flow field and explains the intricacies of execution. Lessons learned for obtaining high-quality images of surface flow patterns are discussed in this study. Fluorescent paint is used to provide clear, high-contrast pictures of the recirculation regions on shrouded vane rows. An edge-finding image processing procedure is implemented to provide a quantitative measure of vane-to-vane variability in flow separation, which is approximately 7 % of the suction surface length for Stator 1. Results include images of vane suction side corner separations from all three stages at three loading conditions. Additionally, streakline patterns obtained experimentally are compared with those calculated from computational models. Flow physics associated with vane clocking and increased rotor tip clearance and their implications to stator loss are also investigated with this flow visualization technique. With increased rotor tip clearance, the vane surface flow patterns show a shift to larger separations and more radial flow at the tip. Finally, the effects of instrumentation on the flow field are highlighted.

  7. Use of Caval Subtraction 2D Phase-Contrast MR Imaging to Measure Total Liver and Hepatic Arterial Blood Flow: Preclinical Validation and Initial Clinical Translation.

    PubMed

    Chouhan, Manil D; Mookerjee, Rajeshwar P; Bainbridge, Alan; Walker-Samuel, Simon; Davies, Nathan; Halligan, Steve; Lythgoe, Mark F; Taylor, Stuart A

    2016-09-01

    Purpose To validate caval subtraction two-dimensional (2D) phase-contrast magnetic resonance (MR) imaging measurements of total liver blood flow (TLBF) and hepatic arterial fraction in an animal model and evaluate consistency and reproducibility in humans. Materials and Methods Approval from the institutional ethical committee for animal care and research ethics was obtained. Fifteen Sprague-Dawley rats underwent 2D phase-contrast MR imaging of the portal vein (PV) and infrahepatic and suprahepatic inferior vena cava (IVC). TLBF and hepatic arterial flow were estimated by subtracting infrahepatic from suprahepatic IVC flow and PV flow from estimated TLBF, respectively. Direct PV transit-time ultrasonography (US) and fluorescent microsphere measurements of hepatic arterial fraction were the standards of reference. Thereafter, consistency of caval subtraction phase-contrast MR imaging-derived TLBF and hepatic arterial flow was assessed in 13 volunteers (mean age, 28.3 years ± 1.4) against directly measured phase-contrast MR imaging PV and proper hepatic arterial inflow; reproducibility was measured after 7 days. Bland-Altman analysis of agreement and coefficient of variation comparisons were undertaken. Results There was good agreement between PV flow measured with phase-contrast MR imaging and that measured with transit-time US (mean difference, -3.5 mL/min/100 g; 95% limits of agreement [LOA], ±61.3 mL/min/100 g). Hepatic arterial fraction obtained with caval subtraction agreed well with those with fluorescent microspheres (mean difference, 4.2%; 95% LOA, ±20.5%). Good consistency was demonstrated between TLBF in humans measured with caval subtraction and direct inflow phase-contrast MR imaging (mean difference, -1.3 mL/min/100 g; 95% LOA, ±23.1 mL/min/100 g). TLBF reproducibility at 7 days was similar between the two methods (95% LOA, ±31.6 mL/min/100 g vs ±29.6 mL/min/100 g). Conclusion Caval subtraction phase-contrast MR imaging is a simple and clinically viable method for measuring TLBF and hepatic arterial flow. Online supplemental material is available for this article.

  8. Schlieren image velocimetry measurements in a rocket engine exhaust plume

    NASA Astrophysics Data System (ADS)

    Morales, Rudy; Peguero, Julio; Hargather, Michael

    2017-11-01

    Schlieren image velocimetry (SIV) measures velocity fields by tracking the motion of naturally-occurring turbulent flow features in a compressible flow. Here the technique is applied to measuring the exhaust velocity profile of a liquid rocket engine. The SIV measurements presented include discussion of visibility of structures, image pre-processing for structure visibility, and ability to process resulting images using commercial particle image velocimetry (PIV) codes. The small-scale liquid bipropellant rocket engine operates on nitrous oxide and ethanol as propellants. Predictions of the exhaust velocity are obtained through NASA CEA calculations and simple compressible flow relationships, which are compared against the measured SIV profiles. Analysis of shear layer turbulence along the exhaust plume edge is also presented.

  9. Low dose dynamic myocardial CT perfusion using advanced iterative reconstruction

    NASA Astrophysics Data System (ADS)

    Eck, Brendan L.; Fahmi, Rachid; Fuqua, Christopher; Vembar, Mani; Dhanantwari, Amar; Bezerra, Hiram G.; Wilson, David L.

    2015-03-01

    Dynamic myocardial CT perfusion (CTP) can provide quantitative functional information for the assessment of coronary artery disease. However, x-ray dose in dynamic CTP is high, typically from 10mSv to >20mSv. We compared the dose reduction potential of advanced iterative reconstruction, Iterative Model Reconstruction (IMR, Philips Healthcare, Cleveland, Ohio) to hybrid iterative reconstruction (iDose4) and filtered back projection (FBP). Dynamic CTP scans were obtained using a porcine model with balloon-induced ischemia in the left anterior descending coronary artery to prescribed fractional flow reserve values. High dose dynamic CTP scans were acquired at 100kVp/100mAs with effective dose of 23mSv. Low dose scans at 75mAs, 50mAs, and 25mAs were simulated by adding x-ray quantum noise and detector electronic noise to the projection space data. Images were reconstructed with FBP, iDose4, and IMR at each dose level. Image quality in static CTP images was assessed by SNR and CNR. Blood flow was obtained using a dynamic CTP analysis pipeline and blood flow image quality was assessed using flow-SNR and flow-CNR. IMR showed highest static image quality according to SNR and CNR. Blood flow in FBP was increasingly over-estimated at reduced dose. Flow was more consistent for iDose4 from 100mAs to 50mAs, but was over-estimated at 25mAs. IMR was most consistent from 100mAs to 25mAs. Static images and flow maps for 100mAs FBP, 50mAs iDose4, and 25mAs IMR showed comparable, clear ischemia, CNR, and flow-CNR values. These results suggest that IMR can enable dynamic CTP at significantly reduced dose, at 5.8mSv or 25% of the comparable 23mSv FBP protocol.

  10. In vivo imaging of mammalian cochlear blood flow using fluorescence microendoscopy.

    PubMed

    Monfared, Ashkan; Blevins, Nikolas H; Cheung, Eunice L M; Jung, Juergen C; Popelka, Gerald; Schnitzer, Mark J

    2006-02-01

    We sought to develop techniques for visualizing cochlear blood flow in live mammalian subjects using fluorescence microendoscopy. Inner ear microcirculation appears to be intimately involved in cochlear function. Blood velocity measurements suggest that intense sounds can alter cochlear blood flow. Disruption of cochlear blood flow may be a significant cause of hearing impairment, including sudden sensorineural hearing loss. However, inability to image cochlear blood flow in a nondestructive manner has limited investigation of the role of inner ear microcirculation in hearing function. Present techniques for imaging cochlear microcirculation using intravital light microscopy involve extensive perturbations to cochlear structure, precluding application in human patients. The few previous endoscopy studies of the cochlea have suffered from optical resolution insufficient for visualizing cochlear microvasculature. Fluorescence microendoscopy is an emerging minimally invasive imaging modality that provides micron-scale resolution in tissues inaccessible to light microscopy. In this article, we describe the use of fluorescence microendoscopy in live guinea pigs to image capillary blood flow and movements of individual red blood cells within the basal turn of the cochlea. We anesthetized eight adult guinea pigs and accessed the inner ear through the mastoid bulla. After intravenous injection of fluorescein dye, we made a limited cochleostomy and introduced a compound doublet gradient refractive index endoscope probe 1 mm in diameter into the inner ear. We then imaged cochlear blood flow within individual vessels in an epifluorescence configuration using one-photon fluorescence microendoscopy. We observed single red blood cells passing through individual capillaries in several cochlear structures, including the round window membrane, spiral ligament, osseous spiral lamina, and basilar membrane. Blood flow velocities within inner ear capillaries varied widely, with observed speeds reaching up to approximately 500 microm/s. Fluorescence microendoscopy permits visualization of cochlear microcirculation with micron-scale optical resolution and determination of blood flow velocities through analysis of video sequences.

  11. Retooling Laser Speckle Contrast Analysis Algorithm to Enhance Non-Invasive High Resolution Laser Speckle Functional Imaging of Cutaneous Microcirculation

    NASA Astrophysics Data System (ADS)

    Gnyawali, Surya C.; Blum, Kevin; Pal, Durba; Ghatak, Subhadip; Khanna, Savita; Roy, Sashwati; Sen, Chandan K.

    2017-01-01

    Cutaneous microvasculopathy complicates wound healing. Functional assessment of gated individual dermal microvessels is therefore of outstanding interest. Functional performance of laser speckle contrast imaging (LSCI) systems is compromised by motion artefacts. To address such weakness, post-processing of stacked images is reported. We report the first post-processing of binary raw data from a high-resolution LSCI camera. Sharp images of low-flowing microvessels were enabled by introducing inverse variance in conjunction with speckle contrast in Matlab-based program code. Extended moving window averaging enhanced signal-to-noise ratio. Functional quantitative study of blood flow kinetics was performed on single gated microvessels using a free hand tool. Based on detection of flow in low-flow microvessels, a new sharp contrast image was derived. Thus, this work presents the first distinct image with quantitative microperfusion data from gated human foot microvasculature. This versatile platform is applicable to study a wide range of tissue systems including fine vascular network in murine brain without craniotomy as well as that in the murine dorsal skin. Importantly, the algorithm reported herein is hardware agnostic and is capable of post-processing binary raw data from any camera source to improve the sensitivity of functional flow data above and beyond standard limits of the optical system.

  12. Retooling Laser Speckle Contrast Analysis Algorithm to Enhance Non-Invasive High Resolution Laser Speckle Functional Imaging of Cutaneous Microcirculation

    PubMed Central

    Gnyawali, Surya C.; Blum, Kevin; Pal, Durba; Ghatak, Subhadip; Khanna, Savita; Roy, Sashwati; Sen, Chandan K.

    2017-01-01

    Cutaneous microvasculopathy complicates wound healing. Functional assessment of gated individual dermal microvessels is therefore of outstanding interest. Functional performance of laser speckle contrast imaging (LSCI) systems is compromised by motion artefacts. To address such weakness, post-processing of stacked images is reported. We report the first post-processing of binary raw data from a high-resolution LSCI camera. Sharp images of low-flowing microvessels were enabled by introducing inverse variance in conjunction with speckle contrast in Matlab-based program code. Extended moving window averaging enhanced signal-to-noise ratio. Functional quantitative study of blood flow kinetics was performed on single gated microvessels using a free hand tool. Based on detection of flow in low-flow microvessels, a new sharp contrast image was derived. Thus, this work presents the first distinct image with quantitative microperfusion data from gated human foot microvasculature. This versatile platform is applicable to study a wide range of tissue systems including fine vascular network in murine brain without craniotomy as well as that in the murine dorsal skin. Importantly, the algorithm reported herein is hardware agnostic and is capable of post-processing binary raw data from any camera source to improve the sensitivity of functional flow data above and beyond standard limits of the optical system. PMID:28106129

  13. Validation of the Social Appearance Anxiety Scale in Patients with Systemic Sclerosis: A Scleroderma Patient-centered Intervention Network Cohort Study.

    PubMed

    Mills, Sarah D; Kwakkenbos, Linda; Carrier, Marie-Eve; Gholizadeh, Shadi; Fox, Rina S; Jewett, Lisa R; Gottesman, Karen; Roesch, Scott C; Thombs, Brett D; Malcarne, Vanessa L

    2018-01-17

    Systemic sclerosis (SSc) is an autoimmune disease that can cause disfiguring changes in appearance. This study examined the structural validity, internal consistency reliability, convergent validity, and measurement equivalence of the Social Appearance Anxiety Scale (SAAS) across SSc disease subtypes. Patients enrolled in the Scleroderma Patient-centered Intervention Network Cohort completed the SAAS and measures of appearance-related concerns and psychological distress. Confirmatory factor analysis (CFA) was used to examine the structural validity of the SAAS. Multiple-group CFA was used to determine if SAAS scores can be compared across patients with limited and diffuse disease subtypes. Cronbach's alpha was used to examine internal consistency reliability. Correlations of SAAS scores with measures of body image dissatisfaction, fear of negative evaluation, social anxiety, and depression were used to examine convergent validity. SAAS scores were hypothesized to be positively associated with all convergent validity measures, with correlations significant and moderate to large in size. A total of 938 patients with SSc were included. CFA supported a one-factor structure (CFI: .92; SRMR: .04; RMSEA: .08), and multiple-group CFA indicated that the scalar invariance model best fit the data. Internal consistency reliability was good in the total sample (α = .96) and in disease subgroups. Overall, evidence of convergent validity was found with measures of body image dissatisfaction, fear of negative evaluation, social anxiety, and depression. The SAAS can be reliably and validly used to assess fear of appearance evaluation in patients with SSc, and SAAS scores can be meaningfully compared across disease subtypes. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  14. HUNGARIAN EXPERIENCES WITH THE BELIEFS ABOUT ATTRACTIVENESS SCALE.

    PubMed

    Czeglédi, Edit; Szabo, Kornélia

    2016-03-30

    Sociocultural influences regarding bodily appearance and their psychological consequences play a considerable role in the development and maintenance of body image disturbance and eating disorders. The purpose of the study was to explore the psychometric properties of the Beliefs About Attractiveness Scale-Revised and its correlates among young adults in Hungary. In our cross-sectional online study, participants were 18-35 years old (N = 820, 40% male). self-reported anthropometric data, Beliefs About Attractiveness Scale-Revised, Eating Disorder Inventory, SCOFF questionnaire, Sociocultural Attitudes Towards Appearance Questionnaire-3, and Rosenberg Self-esteem Scale. The exploratory factor analysis showed that the fit indices of the three-factor solution are acceptable (χ²(₁₇₁)) = 5124.8, p < 0.001, CFI = 0.944, TLI = 0.918, RMSEA = 0.054, SRMR = 0.030). Along the original 'Importance of being thin' and the 'Importance of being fit' factors, a third factor emerged, namely the 'Life fulfilment aspect of attractiveness' factor. Internal consistency and construct validity of the scales were confirmed. Among those who were at risk of developing an eating disorder, all of the measured beliefs were significantly greater than among those who were not at risk (thin: Z = 6.501, p < 0.001, Cohen's d = 0.63, fit: t(₈₁₈) = -4.749, p < 0.001, Cohen's d = 0.41, and life fulfilment: t(₂₃₉) = -5.702, p < 0.001, Cohen's d = 0.53). The Hungarian version of the Beliefs About Attractiveness Scale-Revised is a reliable, valid measure and we suggest its introduction into Hungarian research. Relationships between beliefs about attractiveness and self- esteem, body image and eating disorders suggest intervention opportunities in with regards to prevention and treatment of eating disorders.

  15. Towards designing an optical-flow based colonoscopy tracking algorithm: a comparative study

    NASA Astrophysics Data System (ADS)

    Liu, Jianfei; Subramanian, Kalpathi R.; Yoo, Terry S.

    2013-03-01

    Automatic co-alignment of optical and virtual colonoscopy images can supplement traditional endoscopic procedures, by providing more complete information of clinical value to the gastroenterologist. In this work, we present a comparative analysis of our optical flow based technique for colonoscopy tracking, in relation to current state of the art methods, in terms of tracking accuracy, system stability, and computational efficiency. Our optical-flow based colonoscopy tracking algorithm starts with computing multi-scale dense and sparse optical flow fields to measure image displacements. Camera motion parameters are then determined from optical flow fields by employing a Focus of Expansion (FOE) constrained egomotion estimation scheme. We analyze the design choices involved in the three major components of our algorithm: dense optical flow, sparse optical flow, and egomotion estimation. Brox's optical flow method,1 due to its high accuracy, was used to compare and evaluate our multi-scale dense optical flow scheme. SIFT6 and Harris-affine features7 were used to assess the accuracy of the multi-scale sparse optical flow, because of their wide use in tracking applications; the FOE-constrained egomotion estimation was compared with collinear,2 image deformation10 and image derivative4 based egomotion estimation methods, to understand the stability of our tracking system. Two virtual colonoscopy (VC) image sequences were used in the study, since the exact camera parameters(for each frame) were known; dense optical flow results indicated that Brox's method was superior to multi-scale dense optical flow in estimating camera rotational velocities, but the final tracking errors were comparable, viz., 6mm vs. 8mm after the VC camera traveled 110mm. Our approach was computationally more efficient, averaging 7.2 sec. vs. 38 sec. per frame. SIFT and Harris affine features resulted in tracking errors of up to 70mm, while our sparse optical flow error was 6mm. The comparison among egomotion estimation algorithms showed that our FOE-constrained egomotion estimation method achieved the optimal balance between tracking accuracy and robustness. The comparative study demonstrated that our optical-flow based colonoscopy tracking algorithm maintains good accuracy and stability for routine use in clinical practice.

  16. The rheology and composition of cryovolcanic flows on icy satellites

    NASA Technical Reports Server (NTRS)

    Kargel, Jeffrey S.

    1993-01-01

    The rheologic properties of terrestrial lavas have been related to morphologic features of their flows, such as levees, banked surfaces, multilobate structures, and compressible folds. These features also have been used to determine rheologies and constrain the compositions of extraterrestrial flows. However, with rare exceptions, such features are not resolvable in Voyager images of the satellites of outer planets. Often only flow length and edge thickness of cryovolcanic flows can be measured reasonably accurately from Voyager images. The semiempirical lava-flow model presented here is a renewed effort to extract useful information from such measurements.

  17. Label-free imaging of developing vasculature in zebrafish with phase variance optical coherence microscopy

    NASA Astrophysics Data System (ADS)

    Chen, Yu; Fingler, Jeff; Trinh, Le A.; Fraser, Scott E.

    2016-03-01

    A phase variance optical coherence microscope (pvOCM) has been created to visualize blood flow in the vasculature of zebrafish embryos, without using exogenous labels. The pvOCM imaging system has axial and lateral resolutions of 2 μm in tissue, and imaging depth of more than 100 μm. Imaging of 2-5 days post-fertilization zebrafish embryos identified the detailed structures of somites, spinal cord, gut and notochord based on intensity contrast. Visualization of the blood flow in the aorta, veins and intersegmental vessels was achieved with phase variance contrast. The pvOCM vasculature images were confirmed with corresponding fluorescence microscopy of a zebrafish transgene that labels the vasculature with green fluorescent protein. The pvOCM images also revealed functional information of the blood flow activities that is crucial for the study of vascular development.

  18. Rapid prototyping raw models on the basis of high resolution computed tomography lung data for respiratory flow dynamics.

    PubMed

    Giesel, Frederik L; Mehndiratta, Amit; von Tengg-Kobligk, Hendrik; Schaeffer, A; Teh, Kevin; Hoffman, E A; Kauczor, Hans-Ulrich; van Beek, E J R; Wild, Jim M

    2009-04-01

    Three-dimensional image reconstruction by volume rendering and rapid prototyping has made it possible to visualize anatomic structures in three dimensions for interventional planning and academic research. Volumetric chest computed tomography was performed on a healthy volunteer. Computed tomographic images of the larger bronchial branches were segmented by an extended three-dimensional region-growing algorithm, converted into a stereolithography file, and used for computer-aided design on a laser sintering machine. The injection of gases for respiratory flow modeling and measurements using magnetic resonance imaging were done on a hollow cast. Manufacturing the rapid prototype took about 40 minutes and included the airway tree from trackea to segmental bronchi (fifth generation). The branching of the airways are clearly visible in the (3)He images, and the radial imaging has the potential to elucidate the airway dimensions. The results for flow patterns in the human bronchial tree using the rapid-prototype model with hyperpolarized helium-3 magnetic resonance imaging show the value of this model for flow phantom studies.

  19. MHz-Rate NO PLIF Imaging in a Mach 10 Hypersonic Wind Tunnel

    NASA Technical Reports Server (NTRS)

    Jiang, N.; Webster, M.; Lempert, Walter R.; Miller, J. D.; Meyer, T. R.; Danehy, Paul M.

    2010-01-01

    NO PLIF imaging at repetition rates as high as 1 MHz is demonstrated in the NASA Langley 31 inch Mach 10 hypersonic wind tunnel. Approximately two hundred time correlated image sequences, of between ten and twenty individual frames, were obtained over eight days of wind tunnel testing spanning two entries in March and September of 2009. The majority of the image sequences were obtained from the boundary layer of a 20 flat plate model, in which transition was induced using a variety of cylindrical and triangular shaped protuberances. The high speed image sequences captured a variety of laminar and transitional flow phenomena, ranging from mostly laminar flow, typically at lower Reynolds number and/or in the near wall region of the model, to highly transitional flow in which the temporal evolution and progression of characteristic streak instabilities and/or corkscrew-shaped vortices could be clearly identified. A series of image sequences were also obtained from a 20 compression ramp at a 10 angle of attack in which the temporal dynamics of the characteristic separated flow was captured in a time correlated manner.

  20. Method and apparatus for optical Doppler tomographic imaging of fluid flow velocity in highly scattering media

    DOEpatents

    Nelson, John Stuart; Milner, Thomas Edward; Chen, Zhongping

    1999-01-01

    Optical Doppler tomography permits imaging of fluid flow velocity in highly scattering media. The tomography system combines Doppler velocimetry with high spatial resolution of partially coherent optical interferometry to measure fluid flow velocity at discrete spatial locations. Noninvasive in vivo imaging of blood flow dynamics and tissue structures with high spatial resolutions of the order of 2 to 10 microns is achieved in biological systems. The backscattered interference signals derived from the interferometer may be analyzed either through power spectrum determination to obtain the position and velocity of each particle in the fluid flow sample at each pixel, or the interference spectral density may be analyzed at each frequency in the spectrum to obtain the positions and velocities of the particles in a cross-section to which the interference spectral density corresponds. The realized resolutions of optical Doppler tomography allows noninvasive in vivo imaging of both blood microcirculation and tissue structure surrounding the vessel which has significance for biomedical research and clinical applications.

  1. From video to computation of biological fluid-structure interaction problems

    NASA Astrophysics Data System (ADS)

    Dillard, Seth I.; Buchholz, James H. J.; Udaykumar, H. S.

    2016-04-01

    This work deals with the techniques necessary to obtain a purely Eulerian procedure to conduct CFD simulations of biological systems with moving boundary flow phenomena. Eulerian approaches obviate difficulties associated with mesh generation to describe or fit flow meshes to body surfaces. The challenges associated with constructing embedded boundary information, body motions and applying boundary conditions on the moving bodies for flow computation are addressed in the work. The overall approach is applied to the study of a fluid-structure interaction problem, i.e., the hydrodynamics of swimming of an American eel, where the motion of the eel is derived from video imaging. It is shown that some first-blush approaches do not work, and therefore, careful consideration of appropriate techniques to connect moving images to flow simulations is necessary and forms the main contribution of the paper. A combination of level set-based active contour segmentation with optical flow and image morphing is shown to enable the image-to-computation process.

  2. Imaging and modeling of flow in porous media using clinical nuclear emission tomography systems and computational fluid dynamics

    NASA Astrophysics Data System (ADS)

    Boutchko, Rostyslav; Rayz, Vitaliy L.; Vandehey, Nicholas T.; O'Neil, James P.; Budinger, Thomas F.; Nico, Peter S.; Druhan, Jennifer L.; Saloner, David A.; Gullberg, Grant T.; Moses, William W.

    2012-01-01

    This paper presents experimental and modeling aspects of applying nuclear emission tomography to study fluid flow in laboratory packed porous media columns of the type frequently used in geophysics, geochemistry and hydrology research. Positron emission tomography (PET) and single photon emission computed tomography (SPECT) are used as non-invasive tools to obtain dynamic 3D images of radioactive tracer concentrations. Dynamic sequences obtained using 18F-FDG PET are used to trace flow through a 5 cm diameter × 20 cm tall sand packed column with and without an impermeable obstacle. In addition, a custom-made rotating column setup placed in a clinical two-headed SPECT camera is used to image 99mTc-DTPA tracer propagation in a through-flowing column (10 cm diameter × 30 cm tall) packed with recovered aquifer sediments. A computational fluid dynamics software package FLUENT is used to model the observed flow dynamics. Tracer distributions obtained in the simulations in the smaller column uniformly packed with sand and in the column with an obstacle are remarkably similar to the reconstructed images in the PET experiments. SPECT results demonstrate strongly non-uniform flow patterns for the larger column slurry-packed with sub-surface sediment and slow upward flow. In the numerical simulation of the SPECT study, two symmetric channels with increased permeability are prescribed along the column walls, which result in the emergence of two well-defined preferential flow paths. Methods and results of this work provide new opportunities in hydrologic and biogeochemical research. The primary target application for developed technologies is non-destructive, non-perturbing, quantitative imaging of flow dynamics within laboratory scale porous media systems.

  3. Imaging and modeling of flow in porous media using clinical nuclear emission tomography systems and computational fluid dynamics.

    PubMed

    Boutchko, Rostyslav; Rayz, Vitaliy L; Vandehey, Nicholas T; O'Neil, James P; Budinger, Thomas F; Nico, Peter S; Druhan, Jennifer L; Saloner, David A; Gullberg, Grant T; Moses, William W

    2012-01-01

    This paper presents experimental and modeling aspects of applying nuclear emission tomography to study fluid flow in laboratory packed porous media columns of the type frequently used in geophysics, geochemistry and hydrology research. Positron emission tomography (PET) and single photon emission computed tomography (SPECT) are used as non-invasive tools to obtain dynamic 3D images of radioactive tracer concentrations. Dynamic sequences obtained using 18 F-FDG PET are used to trace flow through a 5 cm diameter × 20 cm tall sand packed column with and without an impermeable obstacle. In addition, a custom-made rotating column setup placed in a clinical two-headed SPECT camera is used to image 99m Tc-DTPA tracer propagation in a through-flowing column (10 cm diameter × 30 cm tall) packed with recovered aquifer sediments. A computational fluid dynamics software package FLUENT is used to model the observed flow dynamics. Tracer distributions obtained in the simulations in the smaller column uniformly packed with sand and in the column with an obstacle are remarkably similar to the reconstructed images in the PET experiments. SPECT results demonstrate strongly non-uniform flow patterns for the larger column slurry-packed with sub-surface sediment and slow upward flow. In the numerical simulation of the SPECT study, two symmetric channels with increased permeability are prescribed along the column walls, which result in the emergence of two well-defined preferential flow paths. Methods and results of this work provide new opportunities in hydrologic and biogeochemical research. The primary target application for developed technologies is non-destructive, non-perturbing, quantitative imaging of flow dynamics within laboratory scale porous media systems.

  4. Shunt flow evaluation in congenital heart disease based on two-dimensional speckle tracking.

    PubMed

    Fadnes, Solveig; Nyrnes, Siri Ann; Torp, Hans; Lovstakken, Lasse

    2014-10-01

    High-frame-rate ultrasound speckle tracking was used for quantification of peak velocity in shunt flows resulting from septal defects in congenital heart disease. In a duplex acquisition scheme implemented on a research scanner, unfocused transmit beams and full parallel receive beamforming were used to achieve a frame rate of 107 frames/s for full field-of-view flow images with high accuracy, while also ensuring high-quality focused B-mode tissue imaging. The setup was evaluated in vivo for neonates with atrial and ventricular septal defects. The shunt position was automatically tracked in B-mode images and further used in blood speckle tracking to obtain calibrated shunt flow velocities throughout the cardiac cycle. Validation toward color flow imaging and pulsed wave Doppler with manual angle correction indicated that blood speckle tracking could provide accurate estimates of shunt flow velocities. The approach was less biased by clutter filtering compared with color flow imaging and was able to provide velocity estimates beyond the Nyquist range. Possible placements of sample volumes (and angle corrections) for conventional Doppler resulted in a peak shunt velocity variations of 0.49-0.56 m/s for the ventricular septal defect of patient 1 and 0.38-0.58 m/s for the atrial septal defect of patient 2. In comparison, the peak velocities found from speckle tracking were 0.77 and 0.33 m/s for patients 1 and 2, respectively. Results indicated that complex intraventricular flow velocity patterns could be quantified using high-frame-rate speckle tracking of both blood and tissue movement. This could potentially help increase diagnostic accuracy and decrease inter-observer variability when measuring peak velocity in shunt flows. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  5. Automated flow quantification in valvular heart disease based on backscattered Doppler power analysis: implementation on matrix-array ultrasound imaging systems.

    PubMed

    Buck, Thomas; Hwang, Shawn M; Plicht, Björn; Mucci, Ronald A; Hunold, Peter; Erbel, Raimund; Levine, Robert A

    2008-06-01

    Cardiac ultrasound imaging systems are limited in the noninvasive quantification of valvular regurgitation due to indirect measurements and inaccurate hemodynamic assumptions. We recently demonstrated that the principle of integration of backscattered acoustic Doppler power times velocity can be used for flow quantification in valvular regurgitation directly at the vena contracta of a regurgitant flow jet. We now aimed to accomplish implementation of automated Doppler power flow analysis software on a standard cardiac ultrasound system utilizing novel matrix-array transducer technology with detailed description of system requirements, components and software contributing to the system. This system based on a 3.5 MHz, matrix-array cardiac ultrasound scanner (Sonos 5500, Philips Medical Systems) was validated by means of comprehensive experimental signal generator trials, in vitro flow phantom trials and in vivo testing in 48 patients with mitral regurgitation of different severity and etiology using magnetic resonance imaging (MRI) for reference. All measurements displayed good correlation to the reference values, indicating successful implementation of automated Doppler power flow analysis on a matrix-array ultrasound imaging system. Systematic underestimation of effective regurgitant orifice areas >0.65 cm(2) and volumes >40 ml was found due to currently limited Doppler beam width that could be readily overcome by the use of new generation 2D matrix-array technology. Automated flow quantification in valvular heart disease based on backscattered Doppler power can be fully implemented on board a routinely used matrix-array ultrasound imaging systems. Such automated Doppler power flow analysis of valvular regurgitant flow directly, noninvasively, and user independent overcomes the practical limitations of current techniques.

  6. Daedalia Planum

    NASA Image and Video Library

    2012-06-13

    This image from NASA 2001 Mars Odyssey spacecraft of Daedalia Planum shows the termination or end of a single flow. In this case it is the end of the brighter/rougher flow on the right side of the image.

  7. Arcuate Fratures

    NASA Image and Video Library

    2012-10-22

    This image from NASA 2001 Mars Odyssey spacecraft of Daedalia Planum shows the termination or end of a single flow. In this case it is the end of the brighter/rougher flow on the right side of the image.

  8. Ripple Trap

    NASA Technical Reports Server (NTRS)

    2006-01-01

    3 April 2006 This Mars Global Surveyor (MGS) Mars Orbiter Camera (MOC) image shows the margin of a lava flow on a cratered plain in the Athabasca Vallis region of Mars. Remarkably, the cratered plain in this scene is essentially free of bright, windblown ripples. Conversely, the lava flow apparently acted as a trap for windblown materials, illustrated by the presence of the light-toned, wave-like texture over much of the flow. That the lava flow surface trapped windblown sand and granules better than the cratered plain indicates that the flow surface has a rougher texture at a scale too small to resolve in this image.

    Location near: 10.7oN, 204.5oW Image width: 3 km (1.9 mi) Illumination from: lower left Season: Northern Winter

  9. Nyiragonga Volcano

    NASA Image and Video Library

    2002-02-01

    This image of the Nyiragonga volcano eruption in the Congo was acquired on January 28, 2002 by the Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) on NASA's Terra satellite. With its 14spectral bands from the visible to the thermal infrared wavelength region, and its high spatial resolution of 15 to 90 meters about 50 to 300 feet ), ASTER will image Earth for the next 6 years to map and monitor the changing surface of our planet. Image: A river of molten rock poured from the Nyiragongo volcano in the Congo on January 18, 2002, a day after it erupted, killing dozens, swallowing buildings and forcing hundreds of thousands to flee the town of Goma. The flow continued into Lake Kivu. The lave flows are depicted in red on the image indicating they are still hot. Two of them flowed south form the volcano's summit and went through the town of Goma. Another flow can be seen at the top of the image, flowing towards the northwest. One of Africa's most notable volcanoes, Nyiragongo contained an active lava lake in its deep summit crater that drained catastrophically through its outer flanks in 1977. Extremely fluid, fast-moving lava flows draining from the summit lava lake in 1977 killed 50 to 100 people, and several villages were destroyed. The image covers an area of 21 x 24 km and combines a thermal band in red, and two infrared bands in green and blue. http://photojournal.jpl.nasa.gov/catalog/PIA03462

  10. Time-resolved 3D MR velocity mapping at 3T: improved navigator-gated assessment of vascular anatomy and blood flow.

    PubMed

    Markl, Michael; Harloff, Andreas; Bley, Thorsten A; Zaitsev, Maxim; Jung, Bernd; Weigang, Ernst; Langer, Mathias; Hennig, Jürgen; Frydrychowicz, Alex

    2007-04-01

    To evaluate an improved image acquisition and data-processing strategy for assessing aortic vascular geometry and 3D blood flow at 3T. In a study with five normal volunteers and seven patients with known aortic pathology, prospectively ECG-gated cine three-dimensional (3D) MR velocity mapping with improved navigator gating, real-time adaptive k-space ordering and dynamic adjustment of the navigator acceptance criteria was performed. In addition to morphological information and three-directional blood flow velocities, phase-contrast (PC)-MRA images were derived from the same data set, which permitted 3D isosurface rendering of vascular boundaries in combination with visualization of blood-flow patterns. Analysis of navigator performance and image quality revealed improved scan efficiencies of 63.6%+/-10.5% and temporal resolution (<50 msec) compared to previous implementations. Semiquantitative evaluation of image quality by three independent observers demonstrated excellent general image appearance with moderate blurring and minor ghosting artifacts. Results from volunteer and patient examinations illustrate the potential of the improved image acquisition and data-processing strategy for identifying normal and pathological blood-flow characteristics. Navigator-gated time-resolved 3D MR velocity mapping at 3T in combination with advanced data processing is a powerful tool for performing detailed assessments of global and local blood-flow characteristics in the aorta to describe or exclude vascular alterations. Copyright (c) 2007 Wiley-Liss, Inc.

  11. Simultaneous PET/MR imaging of the brain: feasibility of cerebral blood flow measurements with FAIR-TrueFISP arterial spin labeling MRI.

    PubMed

    Stegger, Lars; Martirosian, Petros; Schwenzer, Nina; Bisdas, Sotirios; Kolb, Armin; Pfannenberg, Christina; Claussen, Claus D; Pichler, Bernd; Schick, Fritz; Boss, Andreas

    2012-11-01

    Hybrid positron emission tomography/magnetic resonance imaging (PET/MRI) with simultaneous data acquisition promises a comprehensive evaluation of cerebral pathophysiology on a molecular, anatomical, and functional level. Considering the necessary changes to the MR scanner design the feasibility of arterial spin labeling (ASL) is unclear. To evaluate whether cerebral blood flow imaging with ASL is feasible using a prototype PET/MRI device. ASL imaging of the brain with Flow-sensitive Alternating Inversion Recovery (FAIR) spin preparation and true fast imaging in steady precession (TrueFISP) data readout was performed in eight healthy volunteers sequentially on a prototype PET/MRI and a stand-alone MR scanner with 128 × 128 and 192 × 192 matrix sizes. Cerebral blood flow values for gray matter, signal-to-noise and contrast-to-noise ratios, and relative signal change were compared. Additionally, the feasibility of ASL as part of a clinical hybrid PET/MRI protocol was demonstrated in five patients with intracerebral tumors. Blood flow maps showed good delineation of gray and white matter with no discernible artifacts. The mean blood flow values of the eight volunteers on the PET/MR system were 51 ± 9 and 51 ± 7 mL/100 g/min for the 128 × 128 and 192 × 192 matrices (stand-alone MR, 57 ± 2 and 55 ± 5, not significant). The value for signal-to-noise (SNR) was significantly higher for the PET/MRI system using the 192 × 192 matrix size (P < 0.01), the relative signal change (δS) was significantly lower for the 192 × 192 matrix size (P = 0.02). ASL imaging as part of a clinical hybrid PET/MRI protocol could successfully be accomplished in all patients in diagnostic image quality. ASL brain imaging is feasible with a prototype hybrid PET/MRI scanner, thus adding to the value of this novel imaging technique.

  12. Flow Visualization Studies in the Novacor Left Ventricular Assist System CRADA PC91-002, Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Borovetz, H.S.; Shaffer, F.; Schaub, R.

    This paper discusses a series of experiments to visualize and measure flow fields in the Novacor left ventricular assist system (LVAS). The experiments utilize a multiple exposure, optical imaging technique called fluorescent image tracking velocimetry (FITV) to hack the motion of small, neutrally-buoyant particles in a flowing fluid.

  13. Validity of computational hemodynamics in human arteries based on 3D time-of-flight MR angiography and 2D electrocardiogram gated phase contrast images

    NASA Astrophysics Data System (ADS)

    Yu, Huidan (Whitney); Chen, Xi; Chen, Rou; Wang, Zhiqiang; Lin, Chen; Kralik, Stephen; Zhao, Ye

    2015-11-01

    In this work, we demonstrate the validity of 4-D patient-specific computational hemodynamics (PSCH) based on 3-D time-of-flight (TOF) MR angiography (MRA) and 2-D electrocardiogram (ECG) gated phase contrast (PC) images. The mesoscale lattice Boltzmann method (LBM) is employed to segment morphological arterial geometry from TOF MRA, to extract velocity profiles from ECG PC images, and to simulate fluid dynamics on a unified GPU accelerated computational platform. Two healthy volunteers are recruited to participate in the study. For each volunteer, a 3-D high resolution TOF MRA image and 10 2-D ECG gated PC images are acquired to provide the morphological geometry and the time-varying flow velocity profiles for necessary inputs of the PSCH. Validation results will be presented through comparisons of LBM vs. 4D Flow Software for flow rates and LBM simulation vs. MRA measurement for blood flow velocity maps. Indiana University Health (IUH) Values Fund.

  14. Criterion for Identifying Vortices in High-Pressure Flows

    NASA Technical Reports Server (NTRS)

    Bellan, Josette; Okong'o, Nora

    2007-01-01

    A study of four previously published computational criteria for identifying vortices in high-pressure flows has led to the selection of one of them as the best. This development can be expected to contribute to understanding of high-pressure flows, which occur in diverse settings, including diesel, gas turbine, and rocket engines and the atmospheres of Jupiter and other large gaseous planets. Information on the atmospheres of gaseous planets consists mainly of visual and thermal images of the flows over the planets. Also, validation of recently proposed computational models of high-pressure flows entails comparison with measurements, which are mainly of visual nature. Heretofore, the interpretation of images of high-pressure flows to identify vortices has been based on experience with low-pressure flows. However, high-pressure flows have features distinct from those of low-pressure flows, particularly in regions of high pressure gradient magnitude caused by dynamic turbulent effects and by thermodynamic mixing of chemical species. Therefore, interpretations based on low-pressure behavior may lead to misidentification of vortices and other flow structures in high-pressure flows. The study reported here was performed in recognition of the need for one or more quantitative criteria for identifying coherent flow structures - especially vortices - from previously generated flow-field data, to complement or supersede the determination of flow structures by visual inspection of instantaneous fields or flow animations. The focus in the study was on correlating visible images of flow features with various quantities computed from flow-field data.

  15. Investigating Mars: Pavonis Mons

    NASA Image and Video Library

    2017-11-06

    his image shows part of the eastern flank of Pavonis Mons. Surface lava flows run down hill from the upper left of the image towards the bottom right. Perpendicular to that trend are several linear features. These are faults that encircle the volcano and also run along the linear trend through the three Tharsis volcanoes. This image shows a collapsed lava tube where a flow followed the trend of a graben and then "turned" to flow down hill. Graben are linear features, so lava flows in them are linear. Where the lava flow is running along the surface of the volcano it has sinuosity just like a river. The mode of formation of a lava tube starts with a surface lava flow. The sides and top of the flow cool faster than the center, eventually forming a solid, non-flowing cover of the still flowing lava. The surface flow may have followed the deeper fault block graben (a lower surface than the surroundings). Once the flow stops there remains the empty space lower than the surroundings, and collapse of the top of the tube starts in small pits which coalesce in the linear features. Pavonis Mons is one of the three aligned Tharsis Volcanoes. The four Tharsis volcanoes are Ascreaus Mons, Pavonis Mons, Arsia Mons, and Olympus Mars. All four are shield type volcanoes. Shield volcanoes are formed by lava flows originating near or at the summit, building up layers upon layers of lava. The Hawaiian islands on Earth are shield volcanoes. The three aligned volcanoes are located along a topographic rise in the Tharsis region. Along this trend there are increased tectonic features and additional lava flows. Pavonis Mons is the smallest of the four volcanoes, rising 14km above the mean Mars surface level with a width of 375km. It has a complex summit caldera, with the smallest caldera deeper than the larger caldera. Like most shield volcanoes the surface has a low profile. In the case of Pavonis Mons the average slope is only 4 degrees. The Odyssey spacecraft has spent over 15 years in orbit around Mars, circling the planet more than 69000 times. It holds the record for longest working spacecraft at Mars. THEMIS, the IR/VIS camera system, has collected data for the entire mission and provides images covering all seasons and lighting conditions. Over the years many features of interest have received repeated imaging, building up a suite of images covering the entire feature. From the deepest chasma to the tallest volcano, individual dunes inside craters and dune fields that encircle the north pole, channels carved by water and lava, and a variety of other feature, THEMIS has imaged them all. For the next several months the image of the day will focus on the Tharsis volcanoes, the various chasmata of Valles Marineris, and the major dunes fields. We hope you enjoy these images! Orbit Number: 32751 Latitude: 0.338236 Longitude: 248.74 Instrument: VIS Captured: 2009-05-03 01:57 https://photojournal.jpl.nasa.gov/catalog/PIA22022

  16. Preliminary analyses of SIB-B radar data for recent Hawaii lava flows

    NASA Technical Reports Server (NTRS)

    Kaupp, V. H.; Derryberry, B. A.; Macdonald, H. C.; Gaddis, L. R.; Mouginis-Mark, P. J.

    1986-01-01

    The Shuttle Imaging Radar (SIR-B) experiment acquired two L-band (23 cm wavelength) radar images (at about 28 and 48 deg incidence angles) over the Kilauea Volcano area of southeastern Hawaii. Geologic analysis of these data indicates that, although aa lava flows and pyroclastic deposits can be discriminated, pahoehoe lava flows are not readily distinguished from surrounding low return materials. Preliminary analysis of data extracted from isolated flows indicates that flow type (i.e., aa or pahoehoe) and relative age can be determined from their basic statistics and illumination angle.

  17. The new grasper-integrated single use flexible cystoscope for double J stent removal: evaluation of image quality, flow and flexibility.

    PubMed

    Talso, M; Emiliani, E; Baghdadi, M; Orosa, A; Servian, P; Barreiro, A; Proietti, S; Traxer, O

    2017-08-01

    A new single use digital flexible cystoscope (FC) Isiris α from Coloplast ® with an incorporated grasper has been developed to perform double J stent removal. There is a lack of data regarding the comparison of image quality, flexibility and flow between classic cystoscopes and the new Isiris α. Five different FC were used to compare the image quality, the field of view, the loss of flow and the deflection loss. Two standardized grids, three stones of different composition and a ruler's image were filmed in four standardized different scenarios. These videos were shown to thirty subjects that had to evaluate them. Water outflow was measured in ml/sec in all devices with and without the grasper inside, instruments tip deflection was measured using a software. In the subjective analysis of the image quality Isiris α was the second FC best scored. At 3 cm of distance, the field view of Isiris α was the narrowest. Comparing the water flow in the different FCs, we observed a water flow decrease in all cystoscopes when the grasper was loaded in the working channel. Isiris α deflection and flow increase when the grasper is activated. In terms of quality of vision and water flow, the FC Isiris α is comparable to the other digital FC tested. Field of view is narrower. The results displayed a valid alternative to the standard procedure for DJ removal.

  18. The Mentoring Competency Assessment: validation of a new instrument to evaluate skills of research mentors.

    PubMed

    Fleming, Michael; House, Stephanie; Hanson, Vansa Shewakramani; Yu, Lan; Garbutt, Jane; McGee, Richard; Kroenke, Kurt; Abedin, Zainab; Rubio, Doris M

    2013-07-01

    To determine the psychometric properties of the Mentoring Competency Assessment (MCA), a 26-item skills inventory that enables research mentors and mentees to evaluate six competencies of mentors: maintaining effective communication, aligning expectations, assessing understanding, addressing diversity, fostering independence, and promoting professional development. In 2010, investigators administered the MCA to 283 mentor-mentee pairs from 16 universities participating in a trial of a mentoring curriculum for clinical and translational research mentors. The authors analyzed baseline MCA data to describe the instrument's psychometric properties. Coefficient alpha scores for the MCA showed reliability (internal consistency). The hypothesized model with its six latent constructs (competencies) resulted in an acceptable fit to the data. For the instrument completed by mentors, chi-square = 663.20; df = 284; P < .001; root mean square error of approximation (RMSEA) = 0.069 (90% CI, 0.062-0.076); comparative fit index (CFI) = 0.85; and Tucker-Lewis index (TLI) = 0.83. For the instrument completed by mentees, chi-square = 840.62; df = 284; P < .001; RMSEA = 0.080 (90% CI, 0.063-0.077); CFI = 0.87; and TLI = 0.85. The correlations among the six competencies were high: 0.49-0.87 for mentors, 0.58-0.92 for mentees. All parameter estimates for the individual items were significant; standardized factor loadings ranged from 0.32 to 0.81 for mentors and 0.56 to 0.86 for mentees. The findings demonstrate that the MCA has reliability and validity. In addition, this study provides preliminary norms derived from a national sample of mentors and mentees.

  19. Age and expertise effects in aviation decision making and flight control in a flight simulator.

    PubMed

    Kennedy, Quinn; Taylor, Joy L; Reade, Gordon; Yesavage, Jerome A

    2010-05-01

    Age (due to declines in cognitive abilities necessary for navigation) and level of aviation expertise are two factors that may affect aviation performance and decision making under adverse weather conditions. We examined the roles of age, expertise, and their relationship on aviation decision making and flight control performance during a flight simulator task. Seventy-two IFR-rated general aviators, aged 19-79 yr, made multiple approach, holding pattern entry, and landing decisions while navigating under Instrument Flight Rules weather conditions. Over three trials in which the fog level varied, subjects decided whether or not to land the aircraft. They also completed two holding pattern entries. Subjects' flight control during approaches and holding patterns was measured. Older pilots (41+ yr) were more likely than younger pilots to land when visibility was inadequate (older pilots' mean false alarm rate: 0.44 vs 0.25). They also showed less precise flight control for components of the approach, performing 0.16 SD below mean approach scores. Expertise attenuated an age-related decline in flight control during holding patterns: older IFR/CFI performed 0.73 SD below mean score; younger IFR/CFI, younger CFII/ATP, older CFII/ATP: 0.32, 0.26, 0.03 SD above mean score. Additionally, pilots with faster processing speed (by median split) had a higher mean landing decision false alarm rate (0.42 vs 0.28), yet performed 0.14 SD above the mean approach control score. Results have implications regarding specialized training for older pilots and for understanding processes involved in older adults' real world decision making and performance.

  20. Development and Validation of the Eyelash Satisfaction Questionnaire

    PubMed Central

    Dang, Jeff; Cole, Jason C.; Burgess, Somali M.; Yang, Min; Daniels, Selena R.; Walt, John G.

    2016-01-01

    Background Patient-reported outcome (PRO) measures have been used to assess treatment benefit in a variety of therapeutic areas and are now becoming increasingly important in aesthetic research. Objectives The objective of the current study was to develop and validate a new PRO measure (Eyelash Satisfaction Questionnaire [ESQ]) to assess satisfaction with eyelash prominence. Methods The content of the questionnaire (including conceptual framework and questionnaire items) was generated by review of literature, participant interviews, and expert opinion. Cognitive interviews were conducted to pilot test the questionnaire. Psychometric properties of the questionnaire were examined in a combined sample of participants (n = 970) completing Internet- (n = 909) and paper-based (n = 61) versions. Item- and domain-level properties were examined using modern and classical psychometrics. Results Content-based analysis of qualitative data demonstrated the presence of 3 distinct domains (Length, Fullness, Overall Satisfaction; Confidence, Attractiveness, and Professionalism; and Daily Routine). Initial confirmatory factor analysis (CFA) results of 23 items revealed insufficient model-data fit (comparative fit index [CFI] of 0.86 and a non-normed fit index [NNFI] of 0.82). A revised model using 9 items (3 per domain) achieved appropriate fit (CFI of 0.99 and NNFI of 0.97). Analyses revealed measurement equivalence across the Internet- and paper-based versions. The 3 ESQ domains had strong internal consistency reliability (Cronbach's α [range] = 0.919-0.976) and adequate convergent and discriminant validity. Conclusions The ESQ was found to be a reliable and valid PRO measure for assessing satisfaction with eyelash prominence. Level of Evidence: 3 Therapeutic PMID:26691738

  1. Modeling metabolic syndrome and its association with cognition: the Northern Manhattan study.

    PubMed

    Levin, Bonnie E; Llabre, Maria M; Dong, Chuanhui; Elkind, Mitchell S V; Stern, Yaakov; Rundek, Tatjana; Sacco, Ralph L; Wright, Clinton B

    2014-11-01

    Metabolic syndrome (MetS) is a clustering of vascular risk factors and is associated with increased risk of cardiovascular disease. Less is known about the relationship between MetS and cognition. We examined component vascular risk factors of MetS as correlates of different cognitive domains. The Northern Manhattan Study (NOMAS) includes 1290 stroke-free participants from a largely Hispanic multi-ethnic urban community. We used structural equation modeling (SEM) to model latent variables of MetS, assessed at baseline and an average of 10 years later, at which time participants also underwent a full cognitive battery. The two four-factor models, of the metabolic syndrome (blood pressure, lipid levels, obesity, and fasting glucose) and of cognition (language, executive function, psychomotor, and memory), were each well supported (CFI=0.97 and CFI=0.95, respectively). When the two models were combined, the correlation between metabolic syndrome and cognition was -.31. Among the metabolic syndrome components, only blood pressure uniquely predicted all four cognitive domains. After adjusting for age, gender, race/ethnicity, education, smoking, alcohol, and risk factor treatment variables, blood pressure remained a significant correlate of all domains except memory. In this stroke-free race/ethnically diverse community-based cohort, MetS was associated with cognitive function suggesting that MetS and its components may be important predictors of cognitive outcomes. After adjusting for sociodemographic and vascular risk factors, blood pressure was the strongest correlate of cognitive performance. Findings suggest MetS, and in particular blood pressure, may represent markers of vascular or neurodegenerative damage in aging populations.

  2. Validation of decisional balance and self-efficacy measures for HPV vaccination in college women.

    PubMed

    Lipschitz, Jessica M; Fernandez, Anne C; Larson, H Elsa; Blaney, Cerissa L; Meier, Kathy S; Redding, Colleen A; Prochaska, James O; Paiva, Andrea L

    2013-01-01

    Women younger than 25 years are at greatest risk for human papillomavirus (HPV) infection, including high-risk strains associated with 70% of cervical cancers. Effective model-based measures that can lead to intervention development to increase HPV vaccination rates are necessary. This study validated Transtheoretical Model measures of Decisional Balance and Self-Efficacy for seeking the HPV vaccine in a sample of female college students. Cross-sectional measurement development. Setting. Online survey of undergraduate college students. A total of 340 female students ages 18 to 26 years. Stage of Change, Decisional Balance, and Self-Efficacy. The sample was randomly split into halves for exploratory principal components analyses (PCAs), followed by confirmatory factor analyses (CFAs) to test measurement models. Multivariate analyses examined relationships between constructs. For Decisional Balance, PCA indicated two 4-item factors (Pros -α = .90; and Cons -α = .66). CFA supported a two-factor correlated model, χ(2)(19) = 39.33; p < .01; comparative fit index (CFI) = .97; and average absolute standardized residual statistic (AASR) = .03; with Pros α = .90 and Cons α = .67. For Self-Efficacy, PCA indicated one 6-item factor (α = .84). CFA supported this structure, χ(2)(9) = 50.87; p < .05; CFI = .94; AASR = .03; and α = .90. Multivariate analyses indicated significant cross-stage differences on Pros, Cons, and Self-Efficacy in expected directions. Findings support the internal and external validity of these measures and their use in Transtheoretical Model-tailored interventions. Stage-construct relationships suggest that reducing the Cons of vaccination may be more important for HPV than for behaviors with a true Maintenance stage.

  3. Examination of the Factor Structure of a Global Cognitive Function Battery across Race and Time

    PubMed Central

    Barnes, Lisa L.; Yumoto, Futoshi; Capuano, Ana; Wilson, Robert S.; Bennett, David A.; Tractenberg, Rochelle E.

    2016-01-01

    Older African Americans tend to perform more poorly on cognitive function tests than older Whites. One possible explanation for their poorer performance is that the tests used to assess cognition may not reflect the same construct in African Americans and Whites. Therefore, we tested measurement invariance, by race and over time, of a structured 18-test cognitive battery used in three epidemiologic cohort studies of diverse older adults. Multi-group confirmatory factor analyses were carried out with full-information maximum likelihood estimation in all models to capture as much information as was present in the observed data. Four different aspects of the data were fit to each model: comparative fit index (CFI), standardized root mean square residuals (SRMR), root mean square error of approximation (RMSEA), and model χ2. We found that the most constrained model fit the data well (CFI = 0.950; SRMR = 0.051; RMSEA = 0.057 (90% confidence interval: 0.056, 0.059); the model χ2 = 4600.68 on 862 df), supporting the characterization of this model of cognitive test scores as invariant over time and racial group. These results support the conclusion that the cognitive test battery used in the three studies is invariant across race and time and can be used to assess cognition among African Americans and Whites in longitudinal studies. Furthermore, the lower performance of African Americans on these tests is not due to bias in the tests themselves but rather likely reflect differences in social and environmental experiences over the life course. PMID:26563713

  4. Factor structure and psychometric properties of the english version of the trier inventory for chronic stress (TICS-E).

    PubMed

    Petrowski, Katja; Kliem, Sören; Sadler, Michael; Meuret, Alicia E; Ritz, Thomas; Brähler, Elmar

    2018-02-06

    Demands placed on individuals in occupational and social settings, as well as imbalances in personal traits and resources, can lead to chronic stress. The Trier Inventory for Chronic Stress (TICS) measures chronic stress while incorporating domain-specific aspects, and has been found to be a highly reliable and valid research tool. The aims of the present study were to confirm the German version TICS factorial structure in an English translation of the instrument (TICS-E) and to report its psychometric properties. A random route sample of healthy participants (N = 483) aged 18-30 years completed the TICS-E. The robust maximum likelihood estimation with a mean-adjusted chi-square test statistic was applied due to the sample's significant deviation from the multivariate normal distribution. Goodness of fit, absolute model fit, and relative model fit were assessed by means of the root mean square error of approximation (RMSEA), the Comparative Fit Index (CFI) and the Tucker Lewis Index (TLI). Reliability estimates (Cronbach's α and adjusted split-half reliability) ranged from .84 to .92. Item-scale correlations ranged from .50 to .85. Measures of fit showed values of .052 for RMSEA (Cl = 0.50-.054) and .067 for SRMR for absolute model fit, and values of .846 (TLI) and .855 (CFI) for relative model-fit. Factor loadings ranged from .55 to .91. The psychometric properties and factor structure of the TICS-E are comparable to the German version of the TICS. The instrument therefore meets quality standards for an adequate measurement of chronic stress.

  5. A cross-validation study of the TGMD-2: The case of an adolescent population.

    PubMed

    Issartel, Johann; McGrane, Bronagh; Fletcher, Richard; O'Brien, Wesley; Powell, Danielle; Belton, Sarahjane

    2017-05-01

    This study proposes an extension of a widely used test evaluating fundamental movement skills proficiency to an adolescent population, with a specific emphasis on validity and reliability for this older age group. Cross-sectional observational study. A total of 844 participants (n=456 male, 12.03±0.49) participated in this study. The 12 fundamental movement skills of the TGMD-2 were assessed. Inter-rater reliability was examined to ensure a minimum of 95% consistency between coders. Confirmatory factor analysis was undertaken with a one-factor model (all 12 skills) and two-factor model (6 locomotor skills and 6 object-control skills) as proposed by Ulrich et al. (2000). The model fit was examined using χ 2 , TLI, CFI and RMSEA. Test-retest reliability was carried out with a subsample of 35 participants. The test-retest reliability reached Intraclass Correlation Coefficient of 0.78 (locomotor), 0.76 (object related) and 0.91 (gross motor skill proficiency). The confirmatory factor analysis did not display a good fit for either the one-factor or two-factor model due to a really low contribution of several skills. A reduction in the number of skills to just seven (run, gallop, hop, horizontal jump, bounce, kick and roll) revealed an overall good fit by TLI, CFI and RMSEA measures. The proposed new model offers the possibility of longitudinal studies to track the maturation of fundamental movement skills across the child and adolescent spectrum, while also giving researchers a valid assessment to tool to evaluate adolescent fundamental movement skills proficiency level. Copyright © 2016 Sports Medicine Australia. All rights reserved.

  6. Novel colicin Fy of Yersinia frederiksenii inhibits pathogenic Yersinia strains via YiuR-mediated reception, TonB import, and cell membrane pore formation.

    PubMed

    Bosák, Juraj; Laiblová, Petra; Smarda, Jan; Dedicová, Daniela; Smajs, David

    2012-04-01

    A novel colicin type, designated colicin Fy, was found to be encoded and produced by the strain Yersinia frederiksenii Y27601. Colicin Fy was active against both pathogenic and nonpathogenic strains of the genus Yersinia. Plasmid YF27601 (5,574 bp) of Y. frederiksenii Y27601 was completely sequenced. The colicin Fy activity gene (cfyA) and the colicin Fy immunity gene (cfyI) were identified. The deduced amino acid sequence of colicin Fy was very similar in its C-terminal pore-forming domain to colicin Ib (69% identity in the last 178 amino acid residues), indicating pore forming as its lethal mode of action. Transposon mutagenesis of the colicin Fy-susceptible strain Yersinia kristensenii Y276 revealed the yiuR gene (ykris001_4440), which encodes the YiuR outer membrane protein with unknown function, as the colicin Fy receptor molecule. Introduction of the yiuR gene into the colicin Fy-resistant strain Y. kristensenii Y104 restored its susceptibility to colicin Fy. In contrast, the colicin Fy-resistant strain Escherichia coli TOP10F' acquired susceptibility to colicin Fy only when both the yiuR and tonB genes from Y. kristensenii Y276 were introduced. Similarities between colicins Fy and Ib, similarities between the Cir and YiuR receptors, and the detected partial cross-immunity of colicin Fy and colicin Ib producers suggest a common evolutionary origin of the colicin Fy-YiuR and colicin Ib-Cir systems.

  7. Novel Colicin FY of Yersinia frederiksenii Inhibits Pathogenic Yersinia Strains via YiuR-Mediated Reception, TonB Import, and Cell Membrane Pore Formation

    PubMed Central

    Bosák, Juraj; Laiblová, Petra; Šmarda, Jan; Dědičová, Daniela

    2012-01-01

    A novel colicin type, designated colicin FY, was found to be encoded and produced by the strain Yersinia frederiksenii Y27601. Colicin FY was active against both pathogenic and nonpathogenic strains of the genus Yersinia. Plasmid YF27601 (5,574 bp) of Y. frederiksenii Y27601 was completely sequenced. The colicin FY activity gene (cfyA) and the colicin FY immunity gene (cfyI) were identified. The deduced amino acid sequence of colicin FY was very similar in its C-terminal pore-forming domain to colicin Ib (69% identity in the last 178 amino acid residues), indicating pore forming as its lethal mode of action. Transposon mutagenesis of the colicin FY-susceptible strain Yersinia kristensenii Y276 revealed the yiuR gene (ykris001_4440), which encodes the YiuR outer membrane protein with unknown function, as the colicin FY receptor molecule. Introduction of the yiuR gene into the colicin FY-resistant strain Y. kristensenii Y104 restored its susceptibility to colicin FY. In contrast, the colicin FY-resistant strain Escherichia coli TOP10F′ acquired susceptibility to colicin FY only when both the yiuR and tonB genes from Y. kristensenii Y276 were introduced. Similarities between colicins FY and Ib, similarities between the Cir and YiuR receptors, and the detected partial cross-immunity of colicin FY and colicin Ib producers suggest a common evolutionary origin of the colicin FY-YiuR and colicin Ib-Cir systems. PMID:22343298

  8. Validation of the Malayalam version of the Internalized Stigma of Mental Illness (ISMI) scale.

    PubMed

    James, Tintu; Kutty, V Raman; Boyd, Jennifer; Brzoska, Patrick

    2016-04-01

    Little is known about internalized stigma of mental illness in India. A reason for this could be the lack of valid assessment instruments adapted for the diverse cultures and languages of the country. One of the most widely used and accepted questionnaires to assess internalized stigma is the 29-item Internalized Stigma of Mental Illness (ISMI) scale. The aim of the present study was to translate and adapt the ISMI to the Malayalam-speaking population of Kerala, India and to assess its content and factorial validity. The content validity of the Malayalam-language ISMI was studied through interviews with 7 experts on stigma in India. Factorial validity was examined by means of a confirmatory factor analysis (CFA) based on a cross-sectional survey among 290 patients with mental illness attending follow-up outpatient and primary care clinics in Kerala, India. The expert panel concluded that the items of the translated questionnaire adequately represent internalized stigma in the Malayalam-speaking population of Kerala. The theorized factor structure of the ISMI consisting of five factors showed a suboptimal model fit (WRMR=0.940; TLI=0.971, CFI=0.948; RMSEA=0.059) which improved considerably after removal of the stigma resistance factor and three items with poor factor loadings (WRMR=0.819; TLI=0.982, CFI=0.966; RMSEA=0.051). Although our study identifies some sources of model ill-fit, it shows that a reduced version of the Malayalam-language ISMI can be a valuable tool for the study of internalized stigma in this cultural setting. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Quality of diet and food choices of Finnish young men: a sociodemographic and health behaviour approach.

    PubMed

    Bingham, Clarissa M L; Jallinoja, Piia; Lahti-Koski, Marjaana; Absetz, Pilvikki; Paturi, Merja; Pihlajamäki, Harri; Sahi, Timo; Uutela, Antti

    2010-06-01

    Eating habits of Finns have improved dramatically in 40 years. The proportion of fat in the diet has decreased and vegetable and fruit consumption increased. Knowledge of Finnish young men's dietary habits is limited. The aim was to assess food choices and quality of diet among young men and to analyse how background and health behaviour factors explain it. In 2007, data on eating habits, sociodemographic background factors and health behaviours of 17-21-year-old men (n 2905) entering military service were collected by self-administrated questionnaire. Two indexes - core food index (CFI) and extra food index (EFI) - were formed to describe daily and redundant snacking-type eating, respectively. Associations of background factors and health behaviours on the indexes were analysed by general linear modelling. In all, 13 % consumed fruits and berries daily and 8 % consumed vegetables, whereas 24 % consumed pizza and 19 % consumed hamburgers more than once a week. CFI increased with educational level (P < 0.001) and was explained by background and health behaviour (smoking, physical activity and eating breakfast). EFI was inversely associated with BMI (P < 0.001) and explained by health behaviour: (smoking, physical activity, drinking beer and eating breakfast). These results indicate that in early adulthood, eating habits cluster with other health behaviours among men. In this age group, education is associated with core food but not with extra food eating habits. Furthermore, seasonal variation is seen in both types of eating. When promoting healthy eating, a distinction between core foods and extra foods by using feasible indexes will be helpful in targeting the efforts.

  10. Dimensional analysis of depressive, anxious and somatic symptoms presented by primary care patients and their relationship with ICD-11 PHC proposed diagnoses.

    PubMed

    Ziebold, Carolina; Goldberg, David P; Reed, Geoffrey M; Minhas, Fareed; Razzaque, Bushra; Fortes, Sandra; Robles, Rebeca; Lam, Tai Pong; Bobes, Julio; Iglesias, Celso; Cogo-Moreira, Hugo; García, José Ángel; Mari, Jair J

    2018-06-04

    A study conducted as part of the development of the Eleventh International Classification of Mental Disorders for Primary Health Care (ICD-11 PHC) provided an opportunity to test the relationships among depressive, anxious and somatic symptoms in PHC. Primary care physicians participating in the ICD-11 PHC field studies in five countries selected patients who presented with somatic symptoms not explained by known physical pathology by applying a 29-item screening on somatic complaints that were under study for bodily stress disorder. Patients were interviewed using the Clinical Interview Schedule-Revised and assessed using two five-item scales that measure depressive and anxious symptoms. Structural models of anxious-depressive symptoms and somatic complaints were tested using a bi-factor approach. A total of 797 patients completed the study procedures. Two bi-factor models fit the data well: Model 1 had all symptoms loaded on a general factor, along with one of three specific depression, anxiety and somatic factors [x2 (627) = 741.016, p < 0.0011, RMSEA = 0.015, CFI = 0.911, TLI = 0.9]. Model 2 had a general factor and two specific anxious depression and somatic factors [x2 (627) = 663.065, p = 0.1543, RMSEA = 0.008, CFI = 0.954, TLI = 0.948]. These data along with those of previous studies suggest that depressive, anxious and somatic symptoms are largely different presentations of a common latent phenomenon. This study provides support for the ICD-11 PHC conceptualization of mood disturbance, especially anxious depression, as central among patients who present multiple somatic symptoms.

  11. Evidence of Syndemics and Sexuality-Related Discrimination Among Young Sexual-Minority Women.

    PubMed

    Coulter, Robert W S; Kinsky, Suzanne M; Herrick, Amy L; Stall, Ron D; Bauermeister, José A

    2015-09-01

    Syndemics, or the co-occurrence and interaction of health problems, have been examined extensively among young men who have sex with men, but their existence remain unexamined, to our knowledge, among sexual-minority (i.e., lesbian, gay, and bisexual) women. Thus, we investigated if syndemics were present among young sexual-minority women, and if sexual-orientation discrimination was an independent variable of syndemic production. A total of 467 sexual-minority women between the ages of 18 and 24 completed a cross-sectional online survey regarding their substance use, mental health, sexual behaviors, height, weight, and experiences of discrimination. We used structural equation modeling to investigate the presence of syndemics and their relationship to sexual-orientation discrimination. Heavy episodic drinking, marijuana use, ecstasy use, hallucinogen use, depressive symptoms, multiple sexual partners, and history of sexually transmitted infections (STIs) comprised syndemics in this population (chi-square=24.989, P=.201; comparative fit index [CFI]=0.946; root mean square error of approximation [RMSEA]=0.023). Sexual-orientation discrimination is significantly and positively associated with the latent syndemic variable (unstandardized coefficient=0.095, P<.05), and this model fit the data well (chi-square=33.558, P=.059; CFI=0.914; RMSEA=0.029). The reverse causal model showed syndemics is not an independent variable of sexual-orientation discrimination (unstandardized coefficient=0.602, P>.05). Syndemics appear to be present and associated with sexual-orientation discrimination among young sexual-minority women. Interventions aimed at reducing discrimination or increasing healthy coping may help reduce substance use, depressive symptoms, and sexual risk behaviors in this population.

  12. Psychometric properties of the World Health Organization Disability Assessment Schedule used in the European Study of the Epidemiology of Mental Disorders.

    PubMed

    Buist-Bouwman, M A; Ormel, J; De Graaf, R; Vilagut, G; Alonso, J; Van Sonderen, E; Vollebergh, W A M

    2008-01-01

    This study assessed the factor structure, internal consistency, and discriminatory validity of the World Health Organization Disability Assessment Schedule (WHODAS) version used in the European Study of the Epidemiology of Mental Disorders (ESEMeD). In total 8796 adults were assessed using the ESEMeD WHODAS (22 severity and 8 frequency items). An Exploratory Factor Analysis (EFA) with promax rotation was done with a random 50%. The other half was used for confirmatory factor analysis (CFA) comparing models (a) suggested by EFA; (b) hypothesized a priori; and (c) reduced with four items. A CFA model with covariates was conducted in the whole sample to assess invariance across Mediterranean (Spain, France and Italy) and non-Mediterranean (Belgium, Germany and the Netherlands) countries. Cronbach's alphas and discriminatory validity were also examined. EFA identified seven factors (explained variance: 80%). The reduced model (six factors, four frequency items excluded) presented the best fit [Confirmatory Fit Index (CFI) = 0.992, Tucker-Lewis Index (TLI) = 0.996, Root Mean Square Error of Approximation (RMSEA) = 0.024]. The second-order factor structure also fitted well (CFI = 0.987, TLI = 0.991, RMSEA = 0.036). Measurement non-invariance was found for Embarrassment. Cronbach's alphas ranged from 0.84 for Participation to 0.93 for Mobility. Preliminary data suggest acceptable discriminatory validity. Thus, the ESEMeD WHODAS may well be a valuable shortened version of the WHODAS-II, but future users should reconsider the filter questions. Copyright (c) 2008 John Wiley & Sons, Ltd.

  13. A Short Review on the Synthetic Strategies of Duocarmycin Analogs that are Powerful DNA Alkylating Agents.

    PubMed

    Patil, Pravin C; Satam, Vijay; Lee, Moses

    2015-01-01

    The duocarmycins and CC-1065 are members of a class of DNA minor groove, AT-sequence selective, and adenine-N3 alkylating agents, isolated from Streptomyces sp. that exhibit extremely potent cytotoxicity against the growth of cancer cells grown in culture. Initial synthesis and structural modification of the cyclopropa[c] pyrrolo[3,2-e]indole (CPI) DNA-alkylating motif as well as the indole non-covalent binding region in the 1980s have led to several compounds that entered clinical trials as potential anticancer drugs. However, due to significant systemic toxicity none of the analogs have passed clinical evaluation. As a result, the intensity in the design, synthesis, and development of novel analogs of the duocarmycins has continued. Accordingly, in this review, which covers a period from the 1990s through the present time, the design and synthesis of duocarmycin SA are described along with the synthesis of novel and highly cytotoxic analogs that lack the chiral center. Examples of achiral analogs of duocarmycin SA described in this review include seco-DUMSA (39 and 40), seco-amino-CBI-TMI (13, Centanamycin), and seco-hydroxy-CBI-TMI (14). In addition, another novel class of biologically active duocarmycin SA analogs that contained the seco-iso-cyclopropylfurano[2,3-e]indoline (seco-iso-CFI) and seco-cyclopropyltetrahydrofurano[2,3-f]quinoline (seco-CFQ) DNA alkylating submit was also designed and synthesized. The synthesis of seco-iso-CFI-TMI (10, Tafuramycin A) and seco-CFQ-TMI (11, Tafuramycin B) is included in this review.

  14. Genotype-phenotype correlations of low frequency variants in the complement system in renal disease and age-related macular degeneration.

    PubMed

    Geerlings, M J; Volokhina, E B; de Jong, E K; van de Kar, N; Pauper, M; Hoyng, C B; van den Heuvel, L P; den Hollander, A I

    2018-06-11

    Genetic alterations in the complement system have been linked to a variety of diseases, including atypical hemolytic uremic syndrome (aHUS), C3 glomerulopathy (C3G), and age-related macular degeneration (AMD). We performed sequence analysis of the complement genes CFH, CFI, and C3 in 866 aHUS/C3G and 697 AMD patients. In total we identified 505 low frequency alleles, representing 121 unique variants, of which 51 are novel. CFH contained the largest number of unique low frequency variants (n=64; 53%), followed by C3 (n=32; 26%) and CFI (n=25; 21%). A substantial number of variants were found in both patients groups (n=48; 40%), while 41 (34%) variants were found only in aHUS/C3G and 32 (26%) variants were AMD-specific. Genotype-phenotype correlations between the disease groups identified a higher frequency of protein-altering alleles in SCR20 of Factor H (FH), and in the serine protease domain of Factor I (FI) in aHUS/C3G patients. In AMD a higher frequency of protein-altering alleles was observed in SCR3, SCR5 and SCR7 of FH, the SRCR domain of FI, and in the MG3 domain of C3. In conclusion, we observed a substantial overlap of variants between aHUS/C3G and AMD, however, there is a distinct clustering of variants within specific domains. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  15. Reliability and validity of two self-report measures of cognitive flexibility.

    PubMed

    Johnco, Carly; Wuthrich, Viviana M; Rapee, Ronald M

    2014-12-01

    Neuropsychological testing currently represents the gold standard in assessing cognitive flexibility. However, this format presents some challenges in terms of time and skills required for administration, scoring, and interpretation. Two self-report measures of cognitive flexibility have been developed to measure aspects of cognitive flexibility in everyday settings, although neither has been validated in an older sample. In this study, we investigated the psychometric properties of 2 self-report measures of cognitive flexibility, the Cognitive Flexibility Inventory (CFI; Dennis & Vander Wal, 2010) and the Cognitive Flexibility Scale (CFS; Martin & Rubin, 1995), against neuropsychological measures of cognitive flexibility in a clinical sample of 47 older adults with comorbid anxiety and depression and a nonclinical sample of 53 community-dwelling older adults. Internal consistency was good for the CFS and CFI in all samples. The clinical sample reported poorer cognitive flexibility than did the nonclinical sample on self-report measures and performed more poorly on some neuropsychological measures. There was evidence of convergent validity between the 2 self-report measures but little relationship between the self-report and neuropsychological measures of cognitive flexibility, suggesting that self-report measures assess a different aspect of cognitive flexibility than does neuropsychological testing. Divergent validity was weak from measures of anxiety and depression in the combined and nonclinical samples but acceptable in the clinical sample. Results suggest that these measures are suitable for use with an older adult sample but do not assess the same aspects of cognitive flexibility as are assessed by neuropsychological assessment. (c) 2014 APA, all rights reserved.

  16. Flux or speed? Examining speckle contrast imaging of vascular flows

    PubMed Central

    Kazmi, S. M. Shams; Faraji, Ehssan; Davis, Mitchell A.; Huang, Yu-Yen; Zhang, Xiaojing J.; Dunn, Andrew K.

    2015-01-01

    Speckle contrast imaging enables rapid mapping of relative blood flow distributions using camera detection of back-scattered laser light. However, speckle derived flow measures deviate from direct measurements of erythrocyte speeds by 47 ± 15% (n = 13 mice) in vessels of various calibers. Alternatively, deviations with estimates of volumetric flux are on average 91 ± 43%. We highlight and attempt to alleviate this discrepancy by accounting for the effects of multiple dynamic scattering with speckle imaging of microfluidic channels of varying sizes and then with red blood cell (RBC) tracking correlated speckle imaging of vascular flows in the cerebral cortex. By revisiting the governing dynamic light scattering models, we test the ability to predict the degree of multiple dynamic scattering across vessels in order to correct for the observed discrepancies between relative RBC speeds and multi-exposure speckle imaging estimates of inverse correlation times. The analysis reveals that traditional speckle contrast imagery of vascular flows is neither a measure of volumetric flux nor particle speed, but rather the product of speed and vessel diameter. The corrected speckle estimates of the relative RBC speeds have an average 10 ± 3% deviation in vivo with those obtained from RBC tracking. PMID:26203384

  17. Flux or speed? Examining speckle contrast imaging of vascular flows.

    PubMed

    Kazmi, S M Shams; Faraji, Ehssan; Davis, Mitchell A; Huang, Yu-Yen; Zhang, Xiaojing J; Dunn, Andrew K

    2015-07-01

    Speckle contrast imaging enables rapid mapping of relative blood flow distributions using camera detection of back-scattered laser light. However, speckle derived flow measures deviate from direct measurements of erythrocyte speeds by 47 ± 15% (n = 13 mice) in vessels of various calibers. Alternatively, deviations with estimates of volumetric flux are on average 91 ± 43%. We highlight and attempt to alleviate this discrepancy by accounting for the effects of multiple dynamic scattering with speckle imaging of microfluidic channels of varying sizes and then with red blood cell (RBC) tracking correlated speckle imaging of vascular flows in the cerebral cortex. By revisiting the governing dynamic light scattering models, we test the ability to predict the degree of multiple dynamic scattering across vessels in order to correct for the observed discrepancies between relative RBC speeds and multi-exposure speckle imaging estimates of inverse correlation times. The analysis reveals that traditional speckle contrast imagery of vascular flows is neither a measure of volumetric flux nor particle speed, but rather the product of speed and vessel diameter. The corrected speckle estimates of the relative RBC speeds have an average 10 ± 3% deviation in vivo with those obtained from RBC tracking.

  18. Longitudinal In Vivo Imaging to Assess Blood Flow and Oxygenation in Implantable Engineered Tissues

    PubMed Central

    White, Sean M.; Hingorani, Ryan; Arora, Rajan P.S.; Hughes, Christopher C.W.; George, Steven C.

    2012-01-01

    The functionality of vascular networks within implanted prevascularized tissues is difficult to assess using traditional analysis techniques, such as histology. This is largely due to the inability to visualize hemodynamics in vivo longitudinally. Therefore, we have developed dynamic imaging methods to measure blood flow and hemoglobin oxygen saturation in implanted prevascularized tissues noninvasively and longitudinally. Using laser speckle imaging, multispectral imaging, and intravital microscopy, we demonstrate that fibrin-based tissue implants anastomose with the host (severe combined immunodeficient mice) in as short as 20 h. Anastomosis results in initial perfusion with highly oxygenated blood, and an increase in average hemoglobin oxygenation of 53%. However, shear rates in the preformed vessels were low (20.8±12.8 s−1), and flow did not persist in the vast majority of preformed vessels due to thrombus formation. These findings suggest that designing an appropriate vascular network structure in prevascularized tissues to maintain shear rates above the threshold for thrombosis may be necessary to maintain flow following implantation. We conclude that wide-field and microscopic functional imaging can dynamically assess blood flow and oxygenation in vivo in prevascularized tissues, and can be used to rapidly evaluate and improve prevascularization strategies. PMID:22435776

  19. Fractality of pulsatile flow in speckle images

    NASA Astrophysics Data System (ADS)

    Nemati, M.; Kenjeres, S.; Urbach, H. P.; Bhattacharya, N.

    2016-05-01

    The scattering of coherent light from a system with underlying flow can be used to yield essential information about dynamics of the process. In the case of pulsatile flow, there is a rapid change in the properties of the speckle images. This can be studied using the standard laser speckle contrast and also the fractality of images. In this paper, we report the results of experiments performed to study pulsatile flow with speckle images, under different experimental configurations to verify the robustness of the techniques for applications. In order to study flow under various levels of complexity, the measurements were done for three in-vitro phantoms and two in-vivo situations. The pumping mechanisms were varied ranging from mechanical pumps to the human heart for the in vivo case. The speckle images were analyzed using the techniques of fractal dimension and speckle contrast analysis. The results of these techniques for the various experimental scenarios were compared. The fractal dimension is a more sensitive measure to capture the complexity of the signal though it was observed that it is also extremely sensitive to the properties of the scattering medium and cannot recover the signal for thicker diffusers in comparison to speckle contrast.

  20. Usefulness of tumor blood flow imaging by intraoperative indocyanine green videoangiography in hemangioblastoma surgery.

    PubMed

    Hojo, Masato; Arakawa, Yoshiki; Funaki, Takeshi; Yoshida, Kazumichi; Kikuchi, Takayuki; Takagi, Yasushi; Araki, Yoshio; Ishii, Akira; Kunieda, Takeharu; Takahashi, Jun C; Miyamoto, Susumu

    2014-01-01

    Hemangioblastomas remain a surgical challenge because of their arteriovenous malformation-like character. Recently, indocyanine green (ICG) videoangiography has been applied to neurosurgical vascular surgery. The aim of this study was to evaluate the usefulness of tumor blood flow imaging by intraoperative ICG videoangiography in surgery for hemangioblastomas. Twenty intraoperative ICG videoangiography procedures were performed in 12 patients with hemangioblastomas. Seven lesions were located in the cerebellum, two lesions were in the medulla oblongata, and three lesions were in the spinal cord. Ten procedures were performed before or during dissection, and 10 procedures were performed after tumor resection. ICG videoangiography could provide dynamic images of blood flow in the tumor and its related vessels under surgical view. Interpretation of these dynamic images of tumor blood flow was useful for discrimination of transit feeders (feeders en passage) and also for estimation of unexposed feeders covered with brain parenchyma. Postresection ICG videoangiography could confirm complete tumor resection and normalized blood flow in surrounding vessels. In surgery for hemangioblastomas, careful interpretation of dynamic ICG images can provide useful information on transit feeders and unexposed hidden vessels that cannot be directly visualized by ICG. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. Dust Devil Tracks

    NASA Image and Video Library

    2012-11-13

    This image from NASA 2001 Mars Odyssey spacecraft of Daedalia Planum shows the termination or end of a single flow. In this case it is the end of the brighter/rougher flow on the right side of the image.

  2. Machine Learning Interface for Medical Image Analysis.

    PubMed

    Zhang, Yi C; Kagen, Alexander C

    2017-10-01

    TensorFlow is a second-generation open-source machine learning software library with a built-in framework for implementing neural networks in wide variety of perceptual tasks. Although TensorFlow usage is well established with computer vision datasets, the TensorFlow interface with DICOM formats for medical imaging remains to be established. Our goal is to extend the TensorFlow API to accept raw DICOM images as input; 1513 DaTscan DICOM images were obtained from the Parkinson's Progression Markers Initiative (PPMI) database. DICOM pixel intensities were extracted and shaped into tensors, or n-dimensional arrays, to populate the training, validation, and test input datasets for machine learning. A simple neural network was constructed in TensorFlow to classify images into normal or Parkinson's disease groups. Training was executed over 1000 iterations for each cross-validation set. The gradient descent optimization and Adagrad optimization algorithms were used to minimize cross-entropy between the predicted and ground-truth labels. Cross-validation was performed ten times to produce a mean accuracy of 0.938 ± 0.047 (95 % CI 0.908-0.967). The mean sensitivity was 0.974 ± 0.043 (95 % CI 0.947-1.00) and mean specificity was 0.822 ± 0.207 (95 % CI 0.694-0.950). We extended the TensorFlow API to enable DICOM compatibility in the context of DaTscan image analysis. We implemented a neural network classifier that produces diagnostic accuracies on par with excellent results from previous machine learning models. These results indicate the potential role of TensorFlow as a useful adjunct diagnostic tool in the clinical setting.

  3. Evaluating the Global Precipitation Measurement mission with NOAA/NSSL Multi-Radar Multisensor: current status and future directions.

    NASA Astrophysics Data System (ADS)

    Kirstetter, P. E.; Petersen, W. A.; Gourley, J. J.; Kummerow, C. D.; Huffman, G. J.; Turk, J.; Tanelli, S.; Maggioni, V.; Anagnostou, E. N.; Hong, Y.; Schwaller, M.

    2016-12-01

    Natural gas production via hydraulic fracturing of shale has proliferated on a global scale, yet recovery factors remain low because production strategies are not based on the physics of flow in shale reservoirs. In particular, the physical mechanisms and time scales of depletion from the matrix into the simulated fracture network are not well understood, limiting the potential to optimize operations and reduce environmental impacts. Studying matrix flow is challenging because shale is heterogeneous and has porosity from the μm- to nm-scale. Characterizing nm-scale flow paths requires electron microscopy but the limited field of view does not capture the connectivity and heterogeneity observed at the mm-scale. Therefore, pore-scale models must link to larger volumes to simulate flow on the reservoir-scale. Upscaled models must honor the physics of flow, but at present there is a gap between cm-scale experiments and μm-scale simulations based on ex situ image data. To address this gap, we developed a synchrotron X-ray microscope with an in situ cell to simultaneously visualize and measure flow. We perform coupled flow and microtomography experiments on mm-scale samples from the Barnett, Eagle Ford and Marcellus reservoirs. We measure permeability at various pressures via the pulse-decay method to quantify effective stress dependence and the relative contributions of advective and diffusive mechanisms. Images at each pressure step document how microfractures, interparticle pores, and organic matter change with effective stress. Linking changes in the pore network to flow measurements motivates a physical model for depletion. To directly visualize flow, we measure imbibition rates using inert, high atomic number gases and image periodically with monochromatic beam. By imaging above/below X-ray adsorption edges, we magnify the signal of gas saturation in μm-scale porosity and nm-scale, sub-voxel features. Comparing vacuumed and saturated states yields image-based measurements of the distribution and time scales of imbibition. We also characterize nm-scale structure via focused ion beam tomography to quantify sub-voxel porosity and connectivity. The multi-scale image and flow data is used to develop a framework to upscale and benchmark pore-scale models.

  4. Characterizing relationship between optical microangiography signals and capillary flow using microfluidic channels.

    PubMed

    Choi, Woo June; Qin, Wan; Chen, Chieh-Li; Wang, Jingang; Zhang, Qinqin; Yang, Xiaoqi; Gao, Bruce Z; Wang, Ruikang K

    2016-07-01

    Optical microangiography (OMAG) is a powerful optical angio-graphic tool to visualize micro-vascular flow in vivo. Despite numerous demonstrations for the past several years of the qualitative relationship between OMAG and flow, no convincing quantitative relationship has been proven. In this paper, we attempt to quantitatively correlate the OMAG signal with flow. Specifically, we develop a simplified analytical model of the complex OMAG, suggesting that the OMAG signal is a product of the number of particles in an imaging voxel and the decorrelation of OCT (optical coherence tomography) signal, determined by flow velocity, inter-frame time interval, and wavelength of the light source. Numerical simulation with the proposed model reveals that if the OCT amplitudes are correlated, the OMAG signal is related to a total number of particles across the imaging voxel cross-section per unit time (flux); otherwise it would be saturated but its strength is proportional to the number of particles in the imaging voxel (concentration). The relationship is validated using microfluidic flow phantoms with various preset flow metrics. This work suggests OMAG is a promising quantitative tool for the assessment of vascular flow.

  5. Advanced flow MRI: emerging techniques and applications

    PubMed Central

    Markl, M.; Schnell, S.; Wu, C.; Bollache, E.; Jarvis, K.; Barker, A. J.; Robinson, J. D.; Rigsby, C. K.

    2016-01-01

    Magnetic resonance imaging (MRI) techniques provide non-invasive and non-ionising methods for the highly accurate anatomical depiction of the heart and vessels throughout the cardiac cycle. In addition, the intrinsic sensitivity of MRI to motion offers the unique ability to acquire spatially registered blood flow simultaneously with the morphological data, within a single measurement. In clinical routine, flow MRI is typically accomplished using methods that resolve two spatial dimensions in individual planes and encode the time-resolved velocity in one principal direction, typically oriented perpendicular to the two-dimensional (2D) section. This review describes recently developed advanced MRI flow techniques, which allow for more comprehensive evaluation of blood flow characteristics, such as real-time flow imaging, 2D multiple-venc phase contrast MRI, four-dimensional (4D) flow MRI, quantification of complex haemodynamic properties, and highly accelerated flow imaging. Emerging techniques and novel applications are explored. In addition, applications of these new techniques for the improved evaluation of cardiovascular (aorta, pulmonary arteries, congenital heart disease, atrial fibrillation, coronary arteries) as well as cerebrovascular disease (intra-cranial arteries and veins) are presented. PMID:26944696

  6. Noninvasive assessment of normal carotid bifurcation hemodynamics with color-flow ultrasound imaging.

    PubMed

    Zierler, R E; Phillips, D J; Beach, K W; Primozich, J F; Strandness, D E

    1987-08-01

    The combination of a B-mode imaging system and a single range-gate pulsed Doppler flow velocity detector (duplex scanner) has become the standard noninvasive method for assessing the extracranial carotid artery. However, a significant limitation of this approach is the small area of vessel lumen that can be evaluated at any one time. This report describes a new duplex instrument that displays blood flow as colors superimposed on a real-time B-mode image. Returning echoes from a linear array of transducers are continuously processed for amplitude and phase. Changes in phase are produced by tissue motion and are used to calculate Doppler shift frequency. This results in a color assignment: red and blue indicate direction of flow with respect to the ultrasound beam, and lighter shades represent higher velocities. The carotid bifurcations of 10 normal subjects were studied. Changes in flow velocities across the arterial lumen were clearly visualized as varying shades of red or blue during the cardiac cycle. A region of flow separation was observed in all proximal internal carotids as a blue area located along the outer wall of the bulb. Thus, it is possible to detect the localized flow patterns that characterize normal carotid arteries. Other advantages of color-flow imaging include the ability to rapidly identify the carotid bifurcation branches and any associated anatomic variations.

  7. Magnetic resonance imaging with an optical atomic magnetometer

    PubMed Central

    Xu, Shoujun; Yashchuk, Valeriy V.; Donaldson, Marcus H.; Rochester, Simon M.; Budker, Dmitry; Pines, Alexander

    2006-01-01

    We report an approach for the detection of magnetic resonance imaging without superconducting magnets and cryogenics: optical atomic magnetometry. This technique possesses a high sensitivity independent of the strength of the static magnetic field, extending the applicability of magnetic resonance imaging to low magnetic fields and eliminating imaging artifacts associated with high fields. By coupling with a remote-detection scheme, thereby improving the filling factor of the sample, we obtained time-resolved flow images of water with a temporal resolution of 0.1 s and spatial resolutions of 1.6 mm perpendicular to the flow and 4.5 mm along the flow. Potentially inexpensive, compact, and mobile, our technique provides a viable alternative for MRI detection with substantially enhanced sensitivity and time resolution for various situations where traditional MRI is not optimal. PMID:16885210

  8. Laser Speckle Contrast Imaging of Cerebral Blood Flow

    PubMed Central

    Dunn, Andrew K.

    2011-01-01

    Laser speckle contrast imaging (LSCI) has emerged over the past decade as a powerful, yet simple, method for imaging of blood flow dynamics in real time. The rapid adoption of LSCI for physiological studies is due to the relative ease and low cost of building an instrument as well as the ability to quantify blood flow changes with excellent spatial and temporal resolution. Although measurements are limited to superficial tissues with no depth resolution, LSCI has been instrumental in pre-clinical studies of neurological disorders as well as clinical applications including dermatological, neurosurgical and endoscopic studies. Recently a number of technical advances have been developed to improve the quantitative accuracy and temporal resolution of speckle imaging. This article reviews some of these recent advances and describes several applications of speckle imaging. PMID:22109805

  9. Magnetic particle imaging for in vivo blood flow velocity measurements in mice

    NASA Astrophysics Data System (ADS)

    Kaul, Michael G.; Salamon, Johannes; Knopp, Tobias; Ittrich, Harald; Adam, Gerhard; Weller, Horst; Jung, Caroline

    2018-03-01

    Magnetic particle imaging (MPI) is a new imaging technology. It is a potential candidate to be used for angiographic purposes, to study perfusion and cell migration. The aim of this work was to measure velocities of the flowing blood in the inferior vena cava of mice, using MPI, and to evaluate it in comparison with magnetic resonance imaging (MRI). A phantom mimicking the flow within the inferior vena cava with velocities of up to 21 cm s‑1 was used for the evaluation of the applied analysis techniques. Time–density and distance–density analyses for bolus tracking were performed to calculate flow velocities. These findings were compared with the calibrated velocities set by a flow pump, and it can be concluded that velocities of up to 21 cm s‑1 can be measured by MPI. A time–density analysis using an arrival time estimation algorithm showed the best agreement with the preset velocities. In vivo measurements were performed in healthy FVB mice (n  =  10). MRI experiments were performed using phase contrast (PC) for velocity mapping. For MPI measurements, a standardized injection of a superparamagnetic iron oxide tracer was applied. In vivo MPI data were evaluated by a time–density analysis and compared to PC MRI. A Bland–Altman analysis revealed good agreement between the in vivo velocities acquired by MRI of 4.0  ±  1.5 cm s‑1 and those measured by MPI of 4.8  ±  1.1 cm s‑1. Magnetic particle imaging is a new tool with which to measure and quantify flow velocities. It is fast, radiation-free, and produces 3D images. It therefore offers the potential for vascular imaging.

  10. Simulating nailfold capillaroscopy sequences to evaluate algorithms for blood flow estimation.

    PubMed

    Tresadern, P A; Berks, M; Murray, A K; Dinsdale, G; Taylor, C J; Herrick, A L

    2013-01-01

    The effects of systemic sclerosis (SSc)--a disease of the connective tissue causing blood flow problems that can require amputation of the fingers--can be observed indirectly by imaging the capillaries at the nailfold, though taking quantitative measures such as blood flow to diagnose the disease and monitor its progression is not easy. Optical flow algorithms may be applied, though without ground truth (i.e. known blood flow) it is hard to evaluate their accuracy. We propose an image model that generates realistic capillaroscopy videos with known flow, and use this model to quantify the effect of flow rate, cell density and contrast (among others) on estimated flow. This resource will help researchers to design systems that are robust under real-world conditions.

  11. Evaluation of Sulfur Flow Emplacement on Io from Galileo Data and Numerical Modeling

    NASA Technical Reports Server (NTRS)

    Williams, David A.; Greeley, Ronald; Lopes, Rosaly M. C.; Davies, Ashley G.

    2001-01-01

    Galileo images of bright lava flows surrounding Emakong Patera have bee0 analyzed and numerical modeling has been performed to assess whether these flows could have resulted from the emplacement of sulfur lavas on Io. Images from the solid-state imaging (SSI) camera show that these bright, white to yellow Emakong flows are up to 370 km long and contain dark, sinuous features that are interpreted to be lava conduits, -300-500 m wide and >lo0 km lorig. Neiu-Infrared Mapping S estimate of 344 K f 60 G131'C) within the Bmakong caldera. We suggest that these bright flows likely resulted from either sulfur lavas or silicate lavas that have undergone extensive cooling, pyroclastic mantling, and/or alteration with bright sulfurous materials. The Emakoag bright flows have estimated volume of -250-350 km', similar to some of the smaller Columbia River Basalt flows, If the Emakong flows did result from effusive sulfur eruptions, then they are orders of magnitude reater in volume than any terrestrial sulfur flows. Our numerical modeling capable of traveling tens to hundreds of kilometers, consistent with the predictions of Sagan. Our modeled flow distances are also consistent with the measured lengths of the Emakong channels and bright flows.

  12. Use of three-dimensional time-resolved phase-contrast magnetic resonance imaging with vastly undersampled isotropic projection reconstruction to assess renal blood flow in a renal cell carcinoma patient treated with sunitinib: a case report.

    PubMed

    Takayama, Tatsuya; Takehara, Yasuo; Sugiyama, Masataka; Sugiyama, Takayuki; Ishii, Yasuo; Johnson, Kevin E; Wieben, Oliver; Wakayama, Tetsuya; Sakahara, Harumi; Ozono, Seiichiro

    2014-08-14

    New imaging modalities to assess the efficacy of drugs that have molecular targets remain under development. Here, we describe for the first time the use of time-resolved three-dimensional phase-contrast magnetic resonance imaging to monitor changes in blood supply to a tumor during sunitinib treatment in a patient with localized renal cell carcinoma. A 43-year-old Japanese woman with a tumor-bearing but functional single kidney presented at our hospital in July 2012. Computed tomography and magnetic resonance imaging revealed a cT1aN0M0 renal cell carcinoma embedded in the upper central region of the left kidney. She was prescribed sunitinib as neoadjuvant therapy for 8 months, and then underwent partial nephrectomy. Tumor monitoring during this time was done using time-resolved three-dimensional phase-contrast magnetic resonance imaging, a recent technique which specifically measures blood flow in the various vessels of the kidney. This imaging allowed visualization of the redistribution of renal blood flow during treatment, and showed that flow to the tumor was decreased and flows to other areas increased. Of note, this change occurred in the absence of any change in tumor size. The ability of time-resolved three-dimensional phase-contrast magnetic resonance imaging to provide quantitative information on blood supply to tumors may be useful in monitoring the efficacy of sunitinib treatment.

  13. Systems and methods for thermal imaging technique for measuring mixing of fluids

    DOEpatents

    Booten, Charles; Tomerlin, Jeff; Winkler, Jon

    2016-06-14

    Systems and methods for thermal imaging for measuring mixing of fluids are provided. In one embodiment, a method for measuring mixing of gaseous fluids using thermal imaging comprises: positioning a thermal test medium parallel to a direction gaseous fluid flow from an outlet vent of a momentum source, wherein when the source is operating, the fluid flows across a surface of the medium; obtaining an ambient temperature value from a baseline thermal image of the surface; obtaining at least one operational thermal image of the surface when the fluid is flowing from the outlet vent across the surface, wherein the fluid has a temperature different than the ambient temperature; and calculating at least one temperature-difference fraction associated with at least a first position on the surface based on a difference between temperature measurements obtained from the at least one operational thermal image and the ambient temperature value.

  14. High speed, wide velocity dynamic range Doppler optical coherence tomography (Part III): in vivo endoscopic imaging of blood flow in the rat and human gastrointestinal tracts

    NASA Astrophysics Data System (ADS)

    Yang, Victor X. D.; Gordon, Maggie L.; Tang, Shou-Jiang; Marcon, Norman E.; Gardiner, Geoffrey; Qi, Bing; Bisland, Stuart; Seng-Yue, Emily; Lo, Stewart; Pekar, Julius; Wilson, Brian C.; Vitkin, I. Alex

    2003-09-01

    We previously described a fiber based Doppler optical coherence tomography system [1] capable of imaging embryo cardiac blood flow at 4~16 frames per second with wide velocity dynamic range [2]. Coupling this system to a linear scanning fiber optical catheter design that minimizes friction and vibrations, we report here the initial results of in vivo endoscopic Doppler optical coherence tomography (EDOCT) imaging in normal rat and human esophagus. Microvascular flow in blood vessels less than 100 µm diameter was detected using a combination of color-Doppler and velocity variance imaging modes, during clinical endoscopy using a mobile EDOCT system.

  15. Anti-parallel EUV Flows Observed along Active Region Filament Threads with Hi-C

    NASA Astrophysics Data System (ADS)

    Alexander, Caroline E.; Walsh, Robert W.; Régnier, Stéphane; Cirtain, Jonathan; Winebarger, Amy R.; Golub, Leon; Kobayashi, Ken; Platt, Simon; Mitchell, Nick; Korreck, Kelly; DePontieu, Bart; DeForest, Craig; Weber, Mark; Title, Alan; Kuzin, Sergey

    2013-09-01

    Plasma flows within prominences/filaments have been observed for many years and hold valuable clues concerning the mass and energy balance within these structures. Previous observations of these flows primarily come from Hα and cool extreme-ultraviolet (EUV) lines (e.g., 304 Å) where estimates of the size of the prominence threads has been limited by the resolution of the available instrumentation. Evidence of "counter-steaming" flows has previously been inferred from these cool plasma observations, but now, for the first time, these flows have been directly imaged along fundamental filament threads within the million degree corona (at 193 Å). In this work, we present observations of an AR filament observed with the High-resolution Coronal Imager (Hi-C) that exhibits anti-parallel flows along adjacent filament threads. Complementary data from the Solar Dynamics Observatory (SDO)/Atmospheric Imaging Assembly (AIA) and Helioseismic and Magnetic Imager are presented. The ultra-high spatial and temporal resolution of Hi-C allow the anti-parallel flow velocities to be measured (70-80 km s-1) and gives an indication of the resolvable thickness of the individual strands (0.''8 ± 0.''1). The temperature of the plasma flows was estimated to be log T (K) = 5.45 ± 0.10 using Emission Measure loci analysis. We find that SDO/AIA cannot clearly observe these anti-parallel flows or measure their velocity or thread width due to its larger pixel size. We suggest that anti-parallel/counter-streaming flows are likely commonplace within all filaments and are currently not observed in EUV due to current instrument spatial resolution.

  16. Stress and flow analyses of ultraviolet-curable resin during curing

    NASA Astrophysics Data System (ADS)

    Umezaki, Eisaku; Okano, Akira; Koyama, Hiroto

    2014-06-01

    The stress and flow generated in ultraviolet (UV)-curable resin during curing in molds were measured to investigate their relationship. The specimens were molds consisting of glass plates and acrylic bars, and UV-curable liquid resin. The specimens were illuminated from above with UV rays. Photoelastic and visual images were separately obtained at a constant time interval using cameras during curing. To help obtain the visual images, acrylic powder was mixed with the liquid resin. The stress was obtained from the photoelastic images by a digital photoelastic technique with phase stepping, and the flow was obtained from the visual images by a particle-tracking velocimetry technique. Results indicate that the stress generated in the UV-curable resin during curing depends on the degree of contact between the mold and the cured area of the resin, and is hardly related to the flow.

  17. Visualization of Concrete Slump Flow Using the Kinect Sensor

    PubMed Central

    Park, Minbeom

    2018-01-01

    Workability is regarded as one of the important parameters of high-performance concrete and monitoring it is essential in concrete quality management at construction sites. The conventional workability test methods are basically based on length and time measured by a ruler and a stopwatch and, as such, inevitably involves human error. In this paper, we propose a 4D slump test method based on digital measurement and data processing as a novel concrete workability test. After acquiring the dynamically changing 3D surface of fresh concrete using a 3D depth sensor during the slump flow test, the stream images are processed with the proposed 4D slump processing algorithm and the results are compressed into a single 4D slump image. This image basically represents the dynamically spreading cross-section of fresh concrete along the time axis. From the 4D slump image, it is possible to determine the slump flow diameter, slump flow time, and slump height at any location simultaneously. The proposed 4D slump test will be able to activate research related to concrete flow simulation and concrete rheology by providing spatiotemporal measurement data of concrete flow. PMID:29510510

  18. Visualization of Concrete Slump Flow Using the Kinect Sensor.

    PubMed

    Kim, Jung-Hoon; Park, Minbeom

    2018-03-03

    Workability is regarded as one of the important parameters of high-performance concrete and monitoring it is essential in concrete quality management at construction sites. The conventional workability test methods are basically based on length and time measured by a ruler and a stopwatch and, as such, inevitably involves human error. In this paper, we propose a 4D slump test method based on digital measurement and data processing as a novel concrete workability test. After acquiring the dynamically changing 3D surface of fresh concrete using a 3D depth sensor during the slump flow test, the stream images are processed with the proposed 4D slump processing algorithm and the results are compressed into a single 4D slump image. This image basically represents the dynamically spreading cross-section of fresh concrete along the time axis. From the 4D slump image, it is possible to determine the slump flow diameter, slump flow time, and slump height at any location simultaneously. The proposed 4D slump test will be able to activate research related to concrete flow simulation and concrete rheology by providing spatiotemporal measurement data of concrete flow.

  19. Water Flow Investigation on Quartz Sand with 13-interval Stimulated Echo Multi Slice Imaging

    NASA Astrophysics Data System (ADS)

    Spindler, Natascha; Pohlmeier, Andreas; Galvosas, Petrik

    2011-03-01

    Understanding root water uptake in soils is of high importance for securing nutrition in the context of climate change and linked phenomena like stronger varying weather conditions (draught, strong rain). One step to understand how root water uptake occurs is the knowledge of the water flow in soil towards plant roots. Magnetic Resonance Imaging (MRI) in combination with q-space imaging is potentially the most powerful analytical tool for non-invasive three dimensional visualization of flow and transport in porous media. Numerous attempts have been made to measure local velocity in porous media by combining velocity phase encoding with fast imaging methods, where flow velocities in the vascular bundles of plant stems were investigated. In contrast to water situated in the cellular structure of plants, NMR signal arising from water in the pore space in soil may be much more affected by the presence of internal magnetic field gradients. In this work we account for the existence of these gradients by employing bipolar pulsed field magnetic gradients for velocity encoding. This enables one to study flow through sand (as a model system for soil) at flow rates relevant for the water uptake of plant roots.

  20. A real-time device for converting Doppler ultrasound audio signals into fluid flow velocity

    PubMed Central

    Hogeman, Cynthia S.; Koch, Dennis W.; Krishnan, Anandi; Momen, Afsana; Leuenberger, Urs A.

    2010-01-01

    A Doppler signal converter has been developed to facilitate cardiovascular and exercise physiology research. This device directly converts audio signals from a clinical Doppler ultrasound imaging system into a real-time analog signal that accurately represents blood flow velocity and is easily recorded by any standard data acquisition system. This real-time flow velocity signal, when simultaneously recorded with other physiological signals of interest, permits the observation of transient flow response to experimental interventions in a manner not possible when using standard Doppler imaging devices. This converted flow velocity signal also permits a more robust and less subjective analysis of data in a fraction of the time required by previous analytic methods. This signal converter provides this capability inexpensively and requires no modification of either the imaging or data acquisition system. PMID:20173048

  1. Direct visualization of hemolymph flow in the heart of a grasshopper (Schistocerca americana)

    PubMed Central

    Lee, Wah-Keat; Socha, John J

    2009-01-01

    Background Hemolymph flow patterns in opaque insects have never been directly visualized due to the lack of an appropriate imaging technique. The required spatial and temporal resolutions, together with the lack of contrast between the hemolymph and the surrounding soft tissue, are major challenges. Previously, indirect techniques have been used to infer insect heart motion and hemolymph flow, but such methods fail to reveal fine-scale kinematics of heartbeat and details of intra-heart flow patterns. Results With the use of microbubbles as high contrast tracer particles, we directly visualized hemolymph flow in a grasshopper (Schistocerca americana) using synchrotron x-ray phase-contrast imaging. In-vivo intra-heart flow patterns and the relationship between respiratory (tracheae and air sacs) and circulatory (heart) systems were directly observed for the first time. Conclusion Synchrotron x-ray phase contrast imaging is the only generally applicable technique that has the necessary spatial, temporal resolutions and sensitivity to directly visualize heart dynamics and flow patterns inside opaque animals. This technique has the potential to illuminate many long-standing questions regarding small animal circulation, encompassing topics such as retrograde heart flow in some insects and the development of flow in embryonic vertebrates. PMID:19272159

  2. Abdominal 4D flow MR imaging in a breath hold: combination of spiral sampling and dynamic compressed sensing for highly accelerated acquisition.

    PubMed

    Dyvorne, Hadrien; Knight-Greenfield, Ashley; Jajamovich, Guido; Besa, Cecilia; Cui, Yong; Stalder, Aurélien; Markl, Michael; Taouli, Bachir

    2015-04-01

    To develop a highly accelerated phase-contrast cardiac-gated volume flow measurement (four-dimensional [4D] flow) magnetic resonance (MR) imaging technique based on spiral sampling and dynamic compressed sensing and to compare this technique with established phase-contrast imaging techniques for the quantification of blood flow in abdominal vessels. This single-center prospective study was compliant with HIPAA and approved by the institutional review board. Ten subjects (nine men, one woman; mean age, 51 years; age range, 30-70 years) were enrolled. Seven patients had liver disease. Written informed consent was obtained from all participants. Two 4D flow acquisitions were performed in each subject, one with use of Cartesian sampling with respiratory tracking and the other with use of spiral sampling and a breath hold. Cartesian two-dimensional (2D) cine phase-contrast images were also acquired in the portal vein. Two observers independently assessed vessel conspicuity on phase-contrast three-dimensional angiograms. Quantitative flow parameters were measured by two independent observers in major abdominal vessels. Intertechnique concordance was quantified by using Bland-Altman and logistic regression analyses. There was moderate to substantial agreement in vessel conspicuity between 4D flow acquisitions in arteries and veins (κ = 0.71 and 0.61, respectively, for observer 1; κ = 0.71 and 0.44 for observer 2), whereas more artifacts were observed with spiral 4D flow (κ = 0.30 and 0.20). Quantitative measurements in abdominal vessels showed good equivalence between spiral and Cartesian 4D flow techniques (lower bound of the 95% confidence interval: 63%, 77%, 60%, and 64% for flow, area, average velocity, and peak velocity, respectively). For portal venous flow, spiral 4D flow was in better agreement with 2D cine phase-contrast flow (95% limits of agreement: -8.8 and 9.3 mL/sec, respectively) than was Cartesian 4D flow (95% limits of agreement: -10.6 and 14.6 mL/sec). The combination of highly efficient spiral sampling with dynamic compressed sensing results in major acceleration for 4D flow MR imaging, which allows comprehensive assessment of abdominal vessel hemodynamics in a single breath hold.

  3. Influence of Spatial Resolution in Three-dimensional Cine Phase Contrast Magnetic Resonance Imaging on the Accuracy of Hemodynamic Analysis

    PubMed Central

    Fukuyama, Atsushi; Isoda, Haruo; Morita, Kento; Mori, Marika; Watanabe, Tomoya; Ishiguro, Kenta; Komori, Yoshiaki; Kosugi, Takafumi

    2017-01-01

    Introduction: We aim to elucidate the effect of spatial resolution of three-dimensional cine phase contrast magnetic resonance (3D cine PC MR) imaging on the accuracy of the blood flow analysis, and examine the optimal setting for spatial resolution using flow phantoms. Materials and Methods: The flow phantom has five types of acrylic pipes that represent human blood vessels (inner diameters: 15, 12, 9, 6, and 3 mm). The pipes were fixed with 1% agarose containing 0.025 mol/L gadolinium contrast agent. A blood-mimicking fluid with human blood property values was circulated through the pipes at a steady flow. Magnetic resonance (MR) images (three-directional phase images with speed information and magnitude images for information of shape) were acquired using the 3-Tesla MR system and receiving coil. Temporal changes in spatially-averaged velocity and maximum velocity were calculated using hemodynamic analysis software. We calculated the error rates of the flow velocities based on the volume flow rates measured with a flowmeter and examined measurement accuracy. Results: When the acrylic pipe was the size of the thoracicoabdominal or cervical artery and the ratio of pixel size for the pipe was set at 30% or lower, spatially-averaged velocity measurements were highly accurate. When the pixel size ratio was set at 10% or lower, maximum velocity could be measured with high accuracy. It was difficult to accurately measure maximum velocity of the 3-mm pipe, which was the size of an intracranial major artery, but the error for spatially-averaged velocity was 20% or less. Conclusions: Flow velocity measurement accuracy of 3D cine PC MR imaging for pipes with inner sizes equivalent to vessels in the cervical and thoracicoabdominal arteries is good. The flow velocity accuracy for the pipe with a 3-mm-diameter that is equivalent to major intracranial arteries is poor for maximum velocity, but it is relatively good for spatially-averaged velocity. PMID:28132996

  4. Cardiovascular cine imaging and flow evaluation using Fast Interrupted Steady-State (FISS) magnetic resonance.

    PubMed

    Edelman, Robert R; Serhal, Ali; Pursnani, Amit; Pang, Jianing; Koktzoglou, Ioannis

    2018-02-19

    Existing cine imaging techniques rely on balanced steady-state free precession (bSSFP) or spoiled gradient-echo readouts, each of which has limitations. For instance, with bSSFP, artifacts occur from rapid through-plane flow and off-resonance effects. We hypothesized that a prototype cine technique, radial fast interrupted steady-state (FISS), could overcome these limitations. The technique was compared with standard cine bSSFP for cardiac function, coronary artery conspicuity, and aortic valve morphology. Given its advantageous properties, we further hypothesized that the cine FISS technique, in combination with arterial spin labeling (ASL), could provide an alternative to phase contrast for visualizing in-plane flow patterns within the aorta and branch vessels. The study was IRB-approved and subjects provided consent. Breath-hold cine FISS and bSSFP were acquired using similar imaging parameters. There was no significant difference in biplane left ventricular ejection fraction or cardiac image quality between the two techniques. Compared with cine bSSFP, cine FISS demonstrated a marked decrease in fat signal which improved conspicuity of the coronary arteries, while suppression of through-plane flow artifact on thin-slice cine FISS images improved visualization of the aortic valve. Banding artifacts in the subcutaneous tissues were reduced. In healthy subjects, dynamic flow patterns were well visualized in the aorta, coronary and renal arteries using cine FISS ASL, even when the slice was substantially thicker than the vessel diameter. Cine FISS demonstrates several benefits for cardiovascular imaging compared with cine bSSFP, including better suppression of fat signal and reduced artifacts from through-plane flow and off-resonance effects. The main drawback is a slight (~ 20%) decrease in temporal resolution. In addition, preliminary results suggest that cine FISS ASL provides a potential alternative to phase contrast techniques for in-plane flow quantification, while enabling an efficient, visually-appealing, semi-projective display of blood flow patterns throughout the course of an artery and its branches.

  5. Choriocapillaris Imaging Using Multiple En Face Optical Coherence Tomography Angiography Image Averaging.

    PubMed

    Uji, Akihito; Balasubramanian, Siva; Lei, Jianqin; Baghdasaryan, Elmira; Al-Sheikh, Mayss; Sadda, SriniVas R

    2017-11-01

    Imaging of the choriocapillaris in vivo is challenging with existing technology. Optical coherence tomography angiography (OCTA), if optimized, could make the imaging less challenging. To investigate multiple en face image averaging on OCTA images of the choriocapillaris. Observational, cross-sectional case series at a referral institutional practice in Los Angeles, California. From the original cohort of 21 healthy individuals, 17 normal eyes of 17 participants were included in the study. The study dates were August to September 2016. All participants underwent OCTA imaging of the macula covering a 3 × 3-mm area using OCTA software (Cirrus 5000 with AngioPlex; Carl Zeiss Meditec). One eye per participant was repeatedly imaged to obtain 9 OCTA cube scan sets. Registration was first performed using superficial capillary plexus images, and this transformation was then applied to the choriocapillaris images. The 9 registered choriocapillaris images were then averaged. Quantitative parameters were measured on binarized OCTA images and compared with the unaveraged OCTA images. Vessel caliber measurement. Seventeen eyes of 17 participants (mean [SD] age, 35.1 [6.0] years; 9 [53%] female; and 9 [53%] of white race/ethnicity) with sufficient image quality were included in this analysis. The single unaveraged images demonstrated a granular appearance, and the vascular pattern was difficult to discern. After averaging, en face choriocapillaris images showed a meshwork appearance. The mean (SD) diameter of the vessels was 22.8 (5.8) µm (range, 9.6-40.2 µm). Compared with the single unaveraged images, the averaged images showed more flow voids (1423 flow voids [95% CI, 967-1909] vs 1254 flow voids [95% CI, 825-1683], P < .001), smaller average size of the flow voids (911 [95% CI, 301-1521] µm2 vs 1364 [95% CI, 645-2083] µm2, P < .001), and greater vessel density (70.7% [95% CI, 61.9%-79.5%] vs 61.9% [95% CI, 56.0%-67.8%], P < .001). The distribution of the number vs sizes of the flow voids was skewed in both unaveraged and averaged images. A linear log-log plot of the distribution showed a more homogeneous distribution in the averaged images compared with the unaveraged images. Multiple en face averaging can improve visualization of the choriocapillaris on OCTA images, transforming the images from a granular appearance to a level where the intervascular spaces can be resolved in healthy volunteers.

  6. SU-F-J-222: Using PET Imaging to Evaluate Proliferation and Blood Flow in Irradiated and Non-Irradiated Bone Marrow 1 Year After Chemoradiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McGuire, S; Ponto, L; Menda, Y

    Purpose: To compare proliferation and blood flow in pelvic and thoracic bone marrow 1 year after pelvic chemoradiation. Methods: Sixteen pelvic cancer patients were enrolled in an IRB-approved protocol to acquire FLT PET images during radiation therapy simulation (baseline) and 1 year after chemoradiation therapy. Three subjects also had optional O-15 water PET images acquired 1 year after chemoradiation therapy. Baseline FLT PET images were used to create IMRT plans to spare pelvic bone marrow identified as regions with FLT SUV ≥ 2 without compromising PTV coverage or OAR sparing. Marrow VOIs were defined using a 50% maximum pixel valuemore » threshold on baseline FLT PET images (VIEW, PMOD version 3.5) in the sacrum and thoracic spine representing irradiated and non-irradiated regions, respectively. FLT PET and O-15 water PET images acquired 1 year after therapy were co-registered to baseline images (FUSION PMOD) and the same VOIs were used to measure proliferation (FLT SUV) and blood flow (O-15 water uptake). Separate image-based input functions were used for blood flow quantitation in each VOI. Results: Mean 1 year FLT SUV in sacral and thoracic VOIs for were 1.1 ± 0.4 and 6.5 ± 1.7, respectively for N = 16 subjects and were 1.2 ± 0.2 and 5.6 ± 1.6, respectively for N = 3 subjects who also underwent O-15 water imaging. Blood flow measures in equivalent sacral and thoracic marrow regions (N = 3) were 21.3 ± 8.7 and 18.3 ± 4.9 mL/min/100mL respectively. Conclusion: Decreased bone marrow proliferation measured by FLT SUV does not appear to correspond to decreased blood flow as measured by O-15 water PET imaging. Based on this small sample at a single time point, reduced blood supply does not explain reductions in bone marrow proliferative activity 1 year after chemoradiation therapy.« less

  7. Use of Caval Subtraction 2D Phase-Contrast MR Imaging to Measure Total Liver and Hepatic Arterial Blood Flow: Preclinical Validation and Initial Clinical Translation

    PubMed Central

    Walker-Samuel, Simon; Davies, Nathan; Halligan, Steve; Lythgoe, Mark F.

    2016-01-01

    Purpose To validate caval subtraction two-dimensional (2D) phase-contrast magnetic resonance (MR) imaging measurements of total liver blood flow (TLBF) and hepatic arterial fraction in an animal model and evaluate consistency and reproducibility in humans. Materials and Methods Approval from the institutional ethical committee for animal care and research ethics was obtained. Fifteen Sprague-Dawley rats underwent 2D phase-contrast MR imaging of the portal vein (PV) and infrahepatic and suprahepatic inferior vena cava (IVC). TLBF and hepatic arterial flow were estimated by subtracting infrahepatic from suprahepatic IVC flow and PV flow from estimated TLBF, respectively. Direct PV transit-time ultrasonography (US) and fluorescent microsphere measurements of hepatic arterial fraction were the standards of reference. Thereafter, consistency of caval subtraction phase-contrast MR imaging–derived TLBF and hepatic arterial flow was assessed in 13 volunteers (mean age, 28.3 years ± 1.4) against directly measured phase-contrast MR imaging PV and proper hepatic arterial inflow; reproducibility was measured after 7 days. Bland-Altman analysis of agreement and coefficient of variation comparisons were undertaken. Results There was good agreement between PV flow measured with phase-contrast MR imaging and that measured with transit-time US (mean difference, −3.5 mL/min/100 g; 95% limits of agreement [LOA], ±61.3 mL/min/100 g). Hepatic arterial fraction obtained with caval subtraction agreed well with those with fluorescent microspheres (mean difference, 4.2%; 95% LOA, ±20.5%). Good consistency was demonstrated between TLBF in humans measured with caval subtraction and direct inflow phase-contrast MR imaging (mean difference, −1.3 mL/min/100 g; 95% LOA, ±23.1 mL/min/100 g). TLBF reproducibility at 7 days was similar between the two methods (95% LOA, ±31.6 mL/min/100 g vs ±29.6 mL/min/100 g). Conclusion Caval subtraction phase-contrast MR imaging is a simple and clinically viable method for measuring TLBF and hepatic arterial flow. Online supplemental material is available for this article. PMID:27171018

  8. A Bayesian model for highly accelerated phase-contrast MRI.

    PubMed

    Rich, Adam; Potter, Lee C; Jin, Ning; Ash, Joshua; Simonetti, Orlando P; Ahmad, Rizwan

    2016-08-01

    Phase-contrast magnetic resonance imaging is a noninvasive tool to assess cardiovascular disease by quantifying blood flow; however, low data acquisition efficiency limits the spatial and temporal resolutions, real-time application, and extensions to four-dimensional flow imaging in clinical settings. We propose a new data processing approach called Reconstructing Velocity Encoded MRI with Approximate message passing aLgorithms (ReVEAL) that accelerates the acquisition by exploiting data structure unique to phase-contrast magnetic resonance imaging. The proposed approach models physical correlations across space, time, and velocity encodings. The proposed Bayesian approach exploits the relationships in both magnitude and phase among velocity encodings. A fast iterative recovery algorithm is introduced based on message passing. For validation, prospectively undersampled data are processed from a pulsatile flow phantom and five healthy volunteers. The proposed approach is in good agreement, quantified by peak velocity and stroke volume (SV), with reference data for acceleration rates R≤10. For SV, Pearson r≥0.99 for phantom imaging (n = 24) and r≥0.96 for prospectively accelerated in vivo imaging (n = 10) for R≤10. The proposed approach enables accurate quantification of blood flow from highly undersampled data. The technique is extensible to four-dimensional flow imaging, where higher acceleration may be possible due to additional redundancy. Magn Reson Med 76:689-701, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  9. Advances in Automated Plankton Imaging: Enhanced Throughput, Automated Staining, and Extended Deployment Modes for Imaging FlowCytobot

    NASA Astrophysics Data System (ADS)

    Sosik, H. M.; Olson, R. J.; Brownlee, E.; Brosnahan, M.; Crockford, E. T.; Peacock, E.; Shalapyonok, A.

    2016-12-01

    Imaging FlowCytobot (IFCB) was developed to fill a need for automated identification and monitoring of nano- and microplankton, especially phytoplankton in the size range 10 200 micrometer, which are important in coastal blooms (including harmful algal blooms). IFCB uses a combination of flow cytometric and video technology to capture high resolution (1 micrometer) images of suspended particles. This proven, now commercially available, submersible instrument technology has been deployed in fixed time series locations for extended periods (months to years) and in shipboard laboratories where underway water is automatically analyzed during surveys. Building from these successes, we have now constructed and evaluated three new prototype IFCB designs that extend measurement and deployment capabilities. To improve cell counting statistics without degrading image quality, a high throughput version (IFCB-HT) incorporates in-flow acoustic focusing to non-disruptively pre-concentrate cells before the measurement area of the flow cell. To extend imaging to all heterotrophic cells (even those that do not exhibit chlorophyll fluorescence), Staining IFCB (IFCB-S) incorporates automated addition of a live-cell fluorescent stain (fluorescein diacetate) to samples before analysis. A horizontally-oriented IFCB-AV design addresses the need for spatial surveying from surface autonomous vehicles, including design features that reliably eliminate air bubbles and mitigate wave motion impacts. Laboratory evaluation and test deployments in waters near Woods Hole show the efficacy of each of these enhanced IFCB designs.

  10. Real-time clinically oriented array-based in vivo combined photoacoustic and power Doppler imaging

    NASA Astrophysics Data System (ADS)

    Harrison, Tyler; Jeffery, Dean; Wiebe, Edward; Zemp, Roger J.

    2014-03-01

    Photoacoustic imaging has great potential for identifying vascular regions for clinical imaging. In addition to assessing angiogenesis in cancers, there are many other disease processes that result in increased vascularity that present novel targets for photoacoustic imaging. Doppler imaging can provide good localization of large vessels, but poor imaging of small or low flow speed vessels and is susceptible to motion artifacts. Photoacoustic imaging can provide visualization of small vessels, but due to the filtering effects of ultrasound transducers, only shows the edges of large vessels. Thus, we have combined photoacoustic imaging with ultrasound power Doppler to provide contrast agent- free vascular imaging. We use a research-oriented ultrasound array system to provide interlaced ultrasound, Doppler, and photoacoustic imaging. This system features realtime display of all three modalities with adjustable persistence, rejection, and compression. For ease of use in a clinical setting, display of each mode can be disabled. We verify the ability of this system to identify vessels with varying flow speeds using receiver operating characteristic curves, and find that as flow speed falls, photoacoustic imaging becomes a much better method for identifying blood vessels. We also present several in vivo images of the thyroid and several synovial joints to assess the practicality of this imaging for clinical applications.

  11. Fast interactive exploration of 4D MRI flow data

    NASA Astrophysics Data System (ADS)

    Hennemuth, A.; Friman, O.; Schumann, C.; Bock, J.; Drexl, J.; Huellebrand, M.; Markl, M.; Peitgen, H.-O.

    2011-03-01

    1- or 2-directional MRI blood flow mapping sequences are an integral part of standard MR protocols for diagnosis and therapy control in heart diseases. Recent progress in rapid MRI has made it possible to acquire volumetric, 3-directional cine images in reasonable scan time. In addition to flow and velocity measurements relative to arbitrarily oriented image planes, the analysis of 3-dimensional trajectories enables the visualization of flow patterns, local features of flow trajectories or possible paths into specific regions. The anatomical and functional information allows for advanced hemodynamic analysis in different application areas like stroke risk assessment, congenital and acquired heart disease, aneurysms or abdominal collaterals and cranial blood flow. The complexity of the 4D MRI flow datasets and the flow related image analysis tasks makes the development of fast comprehensive data exploration software for advanced flow analysis a challenging task. Most existing tools address only individual aspects of the analysis pipeline such as pre-processing, quantification or visualization, or are difficult to use for clinicians. The goal of the presented work is to provide a software solution that supports the whole image analysis pipeline and enables data exploration with fast intuitive interaction and visualization methods. The implemented methods facilitate the segmentation and inspection of different vascular systems. Arbitrary 2- or 3-dimensional regions for quantitative analysis and particle tracing can be defined interactively. Synchronized views of animated 3D path lines, 2D velocity or flow overlays and flow curves offer a detailed insight into local hemodynamics. The application of the analysis pipeline is shown for 6 cases from clinical practice, illustrating the usefulness for different clinical questions. Initial user tests show that the software is intuitive to learn and even inexperienced users achieve good results within reasonable processing times.

  12. Imaging electron flow from collimating contacts in graphene

    NASA Astrophysics Data System (ADS)

    Bhandari, S.; Lee, G. H.; Watanabe, K.; Taniguchi, T.; Kim, P.; Westervelt, R. M.

    2018-04-01

    The ballistic motion of electrons in graphene opens exciting opportunities for electron-optic devices based on collimated electron beams. We form a collimating contact in a hBN-encapsulated graphene hall bar by adding zigzag contacts on either side of an electron emitter that absorb stray electrons; collimation can be turned off by floating the zig-zag contacts. The electron beam is imaged using a liquid-He cooled scanning gate microscope (SGM). The tip deflects electrons as they pass from the collimating contact to a receiving contact on the opposite side of the channel, and an image of electron flow can be made by displaying the change in transmission as the tip is raster scanned across the sample. The angular half width Δθ of the electron beam is found by applying a perpendicular magnetic field B that bends electron paths into cyclotron orbits. The images reveal that the electron flow from the collimating contact drops quickly at B  =  0.05 T when the electron orbits miss the receiving contact. The flow for the non-collimating case persists longer, up to B  =  0.19 T, due to the broader range of entry angles. Ray-tracing simulations agree well with the experimental images. By fitting the fields B at which the magnitude of electron flow drops in the experimental SGM images, we find Δθ  =  9° for electron flow from the collimating contact, compared with Δθ  =  54° for the non-collimating case.

  13. Velocity filtering applied to optical flow calculations

    NASA Technical Reports Server (NTRS)

    Barniv, Yair

    1990-01-01

    Optical flow is a method by which a stream of two-dimensional images obtained from a forward-looking passive sensor is used to map the three-dimensional volume in front of a moving vehicle. Passive ranging via optical flow is applied here to the helicopter obstacle-avoidance problem. Velocity filtering is used as a field-based method to determine range to all pixels in the initial image. The theoretical understanding and performance analysis of velocity filtering as applied to optical flow is expanded and experimental results are presented.

  14. Evidence for persistent flow and aqueous sedimentation on early Mars.

    PubMed

    Malin, Michael C; Edgett, Kenneth S

    2003-12-12

    Landforms representative of sedimentary processes and environments that occurred early in martian history have been recognized in Mars Global Surveyor Mars Orbiter Camera and Mars Odyssey Thermal Emission Imaging System images. Evidence of distributary, channelized flow (in particular, flow that lasted long enough to foster meandering) and the resulting deposition of a fan-shaped apron of debris indicate persistent flow conditions and formation of at least some large intracrater layered sedimentary sequences within fluvial, and potentially lacustrine, environments.

  15. Videos and images from 25 years of teaching compressible flow

    NASA Astrophysics Data System (ADS)

    Settles, Gary

    2008-11-01

    Compressible flow is a very visual topic due to refractive optical flow visualization and the public fascination with high-speed flight. Films, video clips, and many images are available to convey this in the classroom. An overview of this material is given and selected examples are shown, drawn from educational films, the movies, television, etc., and accumulated over 25 years of teaching basic and advanced compressible-flow courses. The impact of copyright protection and the doctrine of fair use is also discussed.

  16. Young and Old Flows

    NASA Technical Reports Server (NTRS)

    2004-01-01

    [figure removed for brevity, see original site]

    Released 9 April 2004 The Odyssey spacecraft has completed a full Mars year of observations of the red planet. For the next several weeks the Image of the Day will look back over this first mars year. It will focus on four themes: 1) the poles -- with the seasonal changes seen in the retreat and expansion of the caps; 2) craters - with a variety of morphologies relating to impact materials and later alteration, both infilling and exhumation; 3) channels -- the clues to liquid surface flow; and 4) volcanic flow features. While some images have helped answer questions about the history of Mars, many have raised new questions that are still being investigated as Odyssey continues collecting data as it orbits Mars.

    This daytime infrared image was collected Aug. 13, 2003 during southern spring. The upper part of the image shows the relatively young volcanic flows from Arsia Mons, while the bottom exhibits the flow front texture of older flows. The older flows are most likely also from Arsia Mons.

    Image information: IR instrument. Latitude -27.8, Longitude 237.5 East (122.5 West). 19 meter/pixel resolution.

    Note: this THEMIS visual image has not been radiometrically nor geometrically calibrated for this preliminary release. An empirical correction has been performed to remove instrumental effects. A linear shift has been applied in the cross-track and down-track direction to approximate spacecraft and planetary motion. Fully calibrated and geometrically projected images will be released through the Planetary Data System in accordance with Project policies at a later time.

    NASA's Jet Propulsion Laboratory manages the 2001 Mars Odyssey mission for NASA's Office of Space Science, Washington, D.C. The Thermal Emission Imaging System (THEMIS) was developed by Arizona State University, Tempe, in collaboration with Raytheon Santa Barbara Remote Sensing. The THEMIS investigation is led by Dr. Philip Christensen at Arizona State University. Lockheed Martin Astronautics, Denver, is the prime contractor for the Odyssey project, and developed and built the orbiter. Mission operations are conducted jointly from Lockheed Martin and from JPL, a division of the California Institute of Technology in Pasadena.

  17. Magnetic energy flow imaging of magnetic recording head with enhanced resolution and sensitivity by A-MFM using high magnetic moment superparamagnetic tip

    NASA Astrophysics Data System (ADS)

    Kumar, Pawan; Cao, Yongze; Suzuki, Yudai; Yoshimura, Satoru; Saito, Hitoshi

    2018-06-01

    In this report, the magnetic energy flow of AC magnetic field is imaged from a perpendicular magnetic recording head by alternating magnetic force microscopy (A-MFM) with high magnetic moment Co0.43(GdOx)0.57 superparamagnetic (SP) tip. The present magnetic energy flow imaging phenomenon is able to detect the flow direction of AC magnetic field energy from the recording head. A simple model for the flow direction of the AC magnetic energy is given and revealed that when the AC magnetic field energy from the surface of main pole increases, the energy from the side cross section decreases due to the periodical change of magnetization direction at the main pole area. The A-MFM magnetic energy imaging performance by 100 nm Co0.43(GdOx)0.57 SP tip is compared with the magnetic field imaging with the 25 nm Co0.80Zr0.05Nb0.15 soft magnetic (SM) tip. The spatial resolution measured by Fourier analysis for Co0.43(GdOx)0.57 SP tip is enhanced dramatically to ˜10 nm with low thermal noise, as compared to ˜13 nm by Co0.80Zr0.05Nb0.15 SM tip as well as the previously reported MFM tip. Moreover, the sensitivity and resolution are investigated for a range of head current to confirm the suitability of the magnetic energy flow imaging by Co0.43(GdOx)0.57 SP tip to low as well as high magnetic field source. Further, the A-MFM measurements are performed with the 100 nm Au coated conducting tip to investigate the possibility of electrostatic contribution in magnetic energy imaging by Co0.43(GdOx)0.57 SP tip and revealed that the present A-MFM measurement is free from any electrostatic artifacts. The present magnetic energy flow imaging phenomena with the high magnetic moment Co0.43(GdOx)0.57 SP tip provides an avenue for the analysis of the magnetic field energy component from the head field profile.

  18. Estimating rheological properties of lava flows using high-resolution time lapse imaging

    NASA Astrophysics Data System (ADS)

    James, M. R.; Applegarth, L. J.; Pinkerton, H.; Fryer, T.

    2011-12-01

    During effusive eruptions, property and infrastructure can be threatened by lava flow inundation. In order to maximise the effectiveness of the response to such an event, it is necessary to be able to reliably forecast the area that will be affected. One of the major controls on the advance of a lava flow is its rheology, which is spatially and temporally variable, and depends on many underlying factors. Estimating the rheological properties of a lava flow, and the change in these over space and time is therefore of the utmost importance. Here we report estimates of rheological properties made from geometric and velocity measurements on integrated topographic and image data using the method of Ellis et al. (2004) (Ellis B, Wilson L & Pinkerton H (2004) Estimating the rheology of basaltic lava flows. Lunar & Planetary Science XXXV Abst. 1550). These are then compared to the viscosity predicted from composition and temperature by the GRD model (Giordano D, Russell JK, & Dingwell DB (2008) Viscosity of Magmatic Liquids: A Model. Earth & Planetary Science Letters, 271, 123-134). During the 13 May 2008 - 6 July 2009 eruption of Mt Etna, Sicily, lava flows were emplaced into the Valle del Bove, reaching a maximum length of >6 km. Towards the end of the eruption, multiple channelized aa flows were active simultaneously, reaching tens to hundreds of metres in length. Flow lifetimes were of the order hours to days. In the last month of the eruption, we installed a Canon EOS 450D camera at Pizzi Deneri, on the north side of the Valle del Bove, to collect visible images at 15-minute intervals. On one day, topographic data (using a Riegl LPM-321 terrestrial laser scanner) and thermal images (using a FLIR Thermacam S40) were also collected from this location. The fronts of some of the larger flows were tracked through the time lapse image sequence. Using knowledge of the camera imaging geometry, the pixel tracks were reprojected onto the topographic surface to determine flow advance in 3-D geographic coordinates. Integrating the tracking results with the topographic data allows flow lengths and velocities to be extracted. Using these parameters together with estimates of the flow width and thickness, we estimate effective yield strengths, apparent viscosities and Gratz numbers for the tracked flows. We then evaluate the success of this method using predicted viscosities from the GRD model of Giordano et al. (2008).

  19. High PRF ultrafast sliding compound doppler imaging: fully qualitative and quantitative analysis of blood flow

    NASA Astrophysics Data System (ADS)

    Kang, Jinbum; Jang, Won Seuk; Yoo, Yangmo

    2018-02-01

    Ultrafast compound Doppler imaging based on plane-wave excitation (UCDI) can be used to evaluate cardiovascular diseases using high frame rates. In particular, it provides a fully quantifiable flow analysis over a large region of interest with high spatio-temporal resolution. However, the pulse-repetition frequency (PRF) in the UCDI method is limited for high-velocity flow imaging since it has a tradeoff between the number of plane-wave angles (N) and acquisition time. In this paper, we present high PRF ultrafast sliding compound Doppler imaging method (HUSDI) to improve quantitative flow analysis. With the HUSDI method, full scanline images (i.e. each tilted plane wave data) in a Doppler frame buffer are consecutively summed using a sliding window to create high-quality ensemble data so that there is no reduction in frame rate and flow sensitivity. In addition, by updating a new compounding set with a certain time difference (i.e. sliding window step size or L), the HUSDI method allows various Doppler PRFs with the same acquisition data to enable a fully qualitative, retrospective flow assessment. To evaluate the performance of the proposed HUSDI method, simulation, in vitro and in vivo studies were conducted under diverse flow circumstances. In the simulation and in vitro studies, the HUSDI method showed improved hemodynamic representations without reducing either temporal resolution or sensitivity compared to the UCDI method. For the quantitative analysis, the root mean squared velocity error (RMSVE) was measured using 9 angles (-12° to 12°) with L of 1-9, and the results were found to be comparable to those of the UCDI method (L  =  N  =  9), i.e.  ⩽0.24 cm s-1, for all L values. For the in vivo study, the flow data acquired from a full cardiac cycle of the femoral vessels of a healthy volunteer were analyzed using a PW spectrogram, and arterial and venous flows were successfully assessed with high Doppler PRF (e.g. 5 kHz at L  =  4). These results indicate that the proposed HUSDI method can improve flow visualization and quantification with a higher frame rate, PRF and flow sensitivity in cardiovascular imaging.

  20. Assessment of blood flow with 68Ga-DOTA PET in experimental inflammation: a validation study using 15O-water

    PubMed Central

    Autio, Anu; Saraste, Antti; Kudomi, Nobuyuki; Saanijoki, Tiina; Johansson, Jarkko; Liljenbäck, Heidi; Tarkia, Miikka; Oikonen, Vesa; Sipilä, Hannu T; Roivainen, Anne

    2014-01-01

    Increased blood flow and vascular permeability are key events in inflammation. Based on the fact that Gadolinium-1,4,7,10-tetraazacyclododecane-N,N‘,N‘‘,N‘‘‘-tetraacetic acid (Gd-DOTA) is commonly used in magnetic resonance (MR) imaging of blood flow (perfusion), we evaluated the feasibility of its Gallium-68 labeled DOTA analog (68Ga-DOTA) for positron emission tomography (PET) imaging of blood flow in experimental inflammation. Adult, male Sprague-Dawley rats with turpentine oil induced sterile skin/muscle inflammation were anesthetized with isoflurane, and imaged under rest and adenosine-induced hyperemia by means of dynamic 2-min Oxygen-15 labeled water (H2 15O) and 30-min 68Ga-DOTA PET. For the quantification of PET data, regions of interest (ROIs) were defined in the focus of inflammation, healthy muscle, myocardium and heart left ventricle. Radioactivity concentration in the ROIs versus time after injection was determined for both tracers and blood flow was calculated using image-derived input. According to the H2 15O PET, blood flow was 0.69 ± 0.15 ml/min/g for inflammation and 0.15 ± 0.03 ml/min/g for muscle during rest. The blood flow remained unchanged during adenosine-induced hyperemia 0.67 ± 0.11 and 0.12 ± 0.03 ml/min/g for inflammation and muscle, respectively, indicating that adenosine has little effect on blood flow in peripheral tissues in rats. High focal uptake of 68Ga-DOTA was seen at the site of inflammation throughout the 30-min PET imaging. According to the 68Ga-DOTA PET, blood flow measured as the blood-to-tissue transport rate (K1) was 0.60 ± 0.07 ml/min/g for inflammation and 0.14 ± 0.06 ml/min/g for muscle during rest and 0.63 ± 0.08 ml/min/g for inflammation and 0.09 ± 0.04 ml/min/g for muscle during adenosine-induced hyperemia. The H2 15O-based blood flow and 68Ga-DOTA-based K1 values correlated well (r = 0.94, P < 0.0001). These results show that 68Ga-DOTA PET imaging is useful for the quantification of increased blood flow induced by inflammation. PMID:25250206

  1. Assessment of blood flow with (68)Ga-DOTA PET in experimental inflammation: a validation study using (15)O-water.

    PubMed

    Autio, Anu; Saraste, Antti; Kudomi, Nobuyuki; Saanijoki, Tiina; Johansson, Jarkko; Liljenbäck, Heidi; Tarkia, Miikka; Oikonen, Vesa; Sipilä, Hannu T; Roivainen, Anne

    2014-01-01

    Increased blood flow and vascular permeability are key events in inflammation. Based on the fact that Gadolinium-1,4,7,10-tetraazacyclododecane-N,N',N'',N'''-tetraacetic acid (Gd-DOTA) is commonly used in magnetic resonance (MR) imaging of blood flow (perfusion), we evaluated the feasibility of its Gallium-68 labeled DOTA analog ((68)Ga-DOTA) for positron emission tomography (PET) imaging of blood flow in experimental inflammation. Adult, male Sprague-Dawley rats with turpentine oil induced sterile skin/muscle inflammation were anesthetized with isoflurane, and imaged under rest and adenosine-induced hyperemia by means of dynamic 2-min Oxygen-15 labeled water (H2 (15)O) and 30-min (68)Ga-DOTA PET. For the quantification of PET data, regions of interest (ROIs) were defined in the focus of inflammation, healthy muscle, myocardium and heart left ventricle. Radioactivity concentration in the ROIs versus time after injection was determined for both tracers and blood flow was calculated using image-derived input. According to the H2 (15)O PET, blood flow was 0.69 ± 0.15 ml/min/g for inflammation and 0.15 ± 0.03 ml/min/g for muscle during rest. The blood flow remained unchanged during adenosine-induced hyperemia 0.67 ± 0.11 and 0.12 ± 0.03 ml/min/g for inflammation and muscle, respectively, indicating that adenosine has little effect on blood flow in peripheral tissues in rats. High focal uptake of (68)Ga-DOTA was seen at the site of inflammation throughout the 30-min PET imaging. According to the (68)Ga-DOTA PET, blood flow measured as the blood-to-tissue transport rate (K1) was 0.60 ± 0.07 ml/min/g for inflammation and 0.14 ± 0.06 ml/min/g for muscle during rest and 0.63 ± 0.08 ml/min/g for inflammation and 0.09 ± 0.04 ml/min/g for muscle during adenosine-induced hyperemia. The H2 (15)O-based blood flow and (68)Ga-DOTA-based K1 values correlated well (r = 0.94, P < 0.0001). These results show that (68)Ga-DOTA PET imaging is useful for the quantification of increased blood flow induced by inflammation.

  2. High PRF ultrafast sliding compound doppler imaging: fully qualitative and quantitative analysis of blood flow.

    PubMed

    Kang, Jinbum; Jang, Won Seuk; Yoo, Yangmo

    2018-02-09

    Ultrafast compound Doppler imaging based on plane-wave excitation (UCDI) can be used to evaluate cardiovascular diseases using high frame rates. In particular, it provides a fully quantifiable flow analysis over a large region of interest with high spatio-temporal resolution. However, the pulse-repetition frequency (PRF) in the UCDI method is limited for high-velocity flow imaging since it has a tradeoff between the number of plane-wave angles (N) and acquisition time. In this paper, we present high PRF ultrafast sliding compound Doppler imaging method (HUSDI) to improve quantitative flow analysis. With the HUSDI method, full scanline images (i.e. each tilted plane wave data) in a Doppler frame buffer are consecutively summed using a sliding window to create high-quality ensemble data so that there is no reduction in frame rate and flow sensitivity. In addition, by updating a new compounding set with a certain time difference (i.e. sliding window step size or L), the HUSDI method allows various Doppler PRFs with the same acquisition data to enable a fully qualitative, retrospective flow assessment. To evaluate the performance of the proposed HUSDI method, simulation, in vitro and in vivo studies were conducted under diverse flow circumstances. In the simulation and in vitro studies, the HUSDI method showed improved hemodynamic representations without reducing either temporal resolution or sensitivity compared to the UCDI method. For the quantitative analysis, the root mean squared velocity error (RMSVE) was measured using 9 angles (-12° to 12°) with L of 1-9, and the results were found to be comparable to those of the UCDI method (L  =  N  =  9), i.e.  ⩽0.24 cm s -1 , for all L values. For the in vivo study, the flow data acquired from a full cardiac cycle of the femoral vessels of a healthy volunteer were analyzed using a PW spectrogram, and arterial and venous flows were successfully assessed with high Doppler PRF (e.g. 5 kHz at L  =  4). These results indicate that the proposed HUSDI method can improve flow visualization and quantification with a higher frame rate, PRF and flow sensitivity in cardiovascular imaging.

  3. Faults and Flows

    NASA Image and Video Library

    2014-10-20

    Lava flows of Daedalia Planum can be seen at the top and bottom portions of this image from NASA 2001 Mars Odyssey spacecraft. The ridge and linear depression in the central part of the image are part of Mangala Fossa, a fault bounded graben.

  4. Observing hydrological processes: recent advancements in surface flow monitoring through image analysis

    NASA Astrophysics Data System (ADS)

    Tauro, Flavia; Grimaldi, Salvatore

    2017-04-01

    Recently, several efforts have been devoted to the design and development of innovative, and often unintended, approaches for the acquisition of hydrological data. Among such pioneering techniques, this presentation reports recent advancements towards the establishment of a novel noninvasive and potentially continuous methodology based on the acquisition and analysis of images for spatially distributed observations of the kinematics of surface waters. The approach aims at enabling rapid, affordable, and accurate surface flow monitoring of natural streams. Flow monitoring is an integral part of hydrological sciences and is essential for disaster risk reduction and the comprehension of natural phenomena. However, water processes are inherently complex to observe: they are characterized by multiscale and highly heterogeneous phenomena which have traditionally demanded sophisticated and costly measurement techniques. Challenges in the implementation of such techniques have also resulted in lack of hydrological data during extreme events, in difficult-to-access environments, and at high temporal resolution. By combining low-cost yet high-resolution images and several velocimetry algorithms, noninvasive flow monitoring has been successfully conducted at highly heterogeneous scales, spanning from rills to highly turbulent streams, and medium-scale rivers, with minimal supervision by external users. Noninvasive image data acquisition has also afforded observations in high flow conditions. Latest novelties towards continuous flow monitoring at the catchment scale have entailed the development of a remote gauge-cam station on the Tiber River and integration of flow monitoring through image analysis with unmanned aerial systems (UASs) technology. The gauge-cam station and the UAS platform both afford noninvasive image acquisition and calibration through an innovative laser-based setup. Compared to traditional point-based instrumentation, images allow for generating surface flow velocity maps which fully describe the kinematics of the velocity field in natural streams. Also, continuous observations provide a close picture of the evolving dynamics of natural water bodies. Despite such promising achievements, dealing with images also involves coping with adverse illumination, massive data handling and storage, and data-intensive computing. Most importantly, establishing a novel observational technique requires estimation of the uncertainty associated to measurements and thorough comparison to existing benchmark approaches. In this presentation, we provide answers to some of these issues and perspectives for future research.

  5. Laser Speckle Contrast Imaging: theory, instrumentation and applications.

    PubMed

    Senarathna, Janaka; Rege, Abhishek; Li, Nan; Thakor, Nitish V

    2013-01-01

    Laser Speckle Contrast Imaging (LSCI) is a wide field of view, non scanning optical technique for observing blood flow. Speckles are produced when coherent light scattered back from biological tissue is diffracted through the limiting aperture of focusing optics. Mobile scatterers cause the speckle pattern to blur; a model can be constructed by inversely relating the degree of blur, termed speckle contrast to the scatterer speed. In tissue, red blood cells are the main source of moving scatterers. Therefore, blood flow acts as a virtual contrast agent, outlining blood vessels. The spatial resolution (~10 μm) and temporal resolution (10 ms to 10 s) of LSCI can be tailored to the application. Restricted by the penetration depth of light, LSCI can only visualize superficial blood flow. Additionally, due to its non scanning nature, LSCI is unable to provide depth resolved images. The simple setup and non-dependence on exogenous contrast agents have made LSCI a popular tool for studying vascular structure and blood flow dynamics. We discuss the theory and practice of LSCI and critically analyze its merit in major areas of application such as retinal imaging, imaging of skin perfusion as well as imaging of neurophysiology.

  6. Coherence Imaging Measurements of Impurity Flow in the CTH and W7-X Experiments

    NASA Astrophysics Data System (ADS)

    Ennis, D. A.; Allen, N. R.; Hartwell, G. J.; Johnson, C. A.; Maurer, D. A.; Allen, S. L.; Samuell, C. M.; Gradic, D.; Konig, R.; Perseo, V.; W7-X Team

    2017-10-01

    Measurements of impurity ion emissivity and velocity in the Compact Toroidal Hybrid (CTH) experiment are achieved with a new optical coherence imaging diagnostic. The Coherence Imaging Spectroscopy (CIS) technique uses an imaging interferometer of fixed delay to provide 2D spectral images, making it ideal for investigating the non-axisymmetric geometry of CTH plasmas. Preliminary analysis of C III interferograms indicate a net toroidal flow on the order of 10 km/s during the time of peak current. Bench tests using Zn and Cd light sources reveal that the temperature of the interferometer optics must be controlled to within 0.01°C to limit phase drift resulting in artificially measured flow. A new collaboration between Auburn University and the Max-Planck-Institute for Plasma Physics is underway to develop two new coherence imaging instruments for ion impurity flow measurements in orthogonal directions to investigate the 3D physics of the W7-X island divertor during OP1.2. A continuous wave laser tunable over most of the visible region will be incorporated to provide immediate and accurate calibrations of both CIS systems during plasma operations. Work supported by USDoE Grant DE-FG02-00ER54610.

  7. Image processing analysis on the air-water slug two-phase flow in a horizontal pipe

    NASA Astrophysics Data System (ADS)

    Dinaryanto, Okto; Widyatama, Arif; Majid, Akmal Irfan; Deendarlianto, Indarto

    2016-06-01

    Slug flow is a part of intermittent flow which is avoided in industrial application because of its irregularity and high pressure fluctuation. Those characteristics cause some problems such as internal corrosion and the damage of the pipeline construction. In order to understand the slug characteristics, some of the measurement techniques can be applied such as wire-mesh sensors, CECM, and high speed camera. The present study was aimed to determine slug characteristics by using image processing techniques. Experiment has been carried out in 26 mm i.d. acrylic horizontal pipe with 9 m long. Air-water flow was recorded 5 m from the air-water mixer using high speed video camera. Each of image sequence was processed using MATLAB. There are some steps including image complement, background subtraction, and image filtering that used in this algorithm to produce binary images. Special treatments also were applied to reduce the disturbance effect of dispersed bubble around the bubble. Furthermore, binary images were used to describe bubble contour and calculate slug parameter such as gas slug length, gas slug velocity, and slug frequency. As a result the effect of superficial gas velocity and superficial liquid velocity on the fundamental parameters can be understood. After comparing the results to the previous experimental results, the image processing techniques is a useful and potential technique to explain the slug characteristics.

  8. Nuclear Magnetic Resonance Relaxation and Imaging Studies on Water Flow in Soil Cores

    NASA Astrophysics Data System (ADS)

    Pohlmeier, Andreas; Haber-Pohlmeier, Sabina; Stapf, Siegfried

    2010-05-01

    Magnetic resonance imaging (MRI) is applied to the study of flow processes in a model and a natural soils core. Since flow velocities in soils are mostly too slow to be monitored directly by MRI flow velocity imaging, Gd-DTPA was used as contrast agent for the first time for flow processes in soils. Apart from its chemical stability the main advantage is the anionic net charge in neutral aqueous solution. Here we can show that this property hinders the adsorption at soil mineral surfaces and therefore retardation. Gd-DTPA turns out to be a very convenient conservative tracer for the investigation of flow processes in model and natural soil cores. With respect to the flow processes in the coaxial model soil column and the natural soil column we found total different flow patterns: In the first case tracer plume moves quite homogeneously only in the inner highly conductive core. No penetration into the outer fine material takes place. In contrast, the natural soil core shows a flow pattern which is characterized by preferential paths avoiding dense regions and preferring loose structures. In the case of the simpler model column also the local flow velocities are calculated by the application of a peak tracking algorithm.

  9. Pāhoehoe flow cooling, discharge, and coverage rates from thermal image chronometry

    USGS Publications Warehouse

    Dehn, Jonathan; Hamilton, Christopher M.; Harris, A. J. L.; Herd, Richard A.; James, M.R.; Lodato, Luigi; Steffke, Andrea

    2007-01-01

    Theoretically- and empirically-derived cooling rates for active pāhoehoe lava flows show that surface cooling is controlled by conductive heat loss through a crust that is thickening with the square root of time. The model is based on a linear relationship that links log(time) with surface cooling. This predictable cooling behavior can be used assess the age of recently emplaced sheet flows from their surface temperatures. Using a single thermal image, or image mosaic, this allows quantification of the variation in areal coverage rates and lava discharge rates over 48 hour periods prior to image capture. For pāhoehoe sheet flow at Kīlauea (Hawai`i) this gives coverage rates of 1–5 m2/min at discharge rates of 0.01–0.05 m3/s, increasing to ∼40 m2/min at 0.4–0.5 m3/s. Our thermal chronometry approach represents a quick and easy method of tracking flow advance over a three-day period using a single, thermal snap-shot.

  10. Ground-to-air flow visualization using Solar Calcium-K line Background-Oriented Schlieren

    NASA Astrophysics Data System (ADS)

    Hill, Michael A.; Haering, Edward A.

    2017-01-01

    The Calcium-K Eclipse Background-Oriented Schlieren experiment was performed as a proof of concept test to evaluate the effectiveness of using the solar disk as a background to perform the Background-Oriented Schlieren (BOS) method of flow visualization. A ground-based imaging system was equipped with a Calcium-K line optical etalon filter to enable the use of the chromosphere of the sun as the irregular background to be used for BOS. A US Air Force T-38 aircraft performed three supersonic runs which eclipsed the sun as viewed from the imaging system. The images were successfully post-processed using optical flow methods to qualitatively reveal the density gradients in the flow around the aircraft.

  11. Coastal Research Imaging Spectrometer

    NASA Technical Reports Server (NTRS)

    Lucey, Paul G.; Williams, Timothy; Horton, Keith A.

    2002-01-01

    The Coastal Research Imaging Spectrometer (CRIS) is an airborne remote-sensing system designed specifically for research on the physical, chemical, and biological characteristics of coastal waters. The CRIS includes a visible-light hyperspectral imaging subsystem for measuring the color of water, which contains information on the biota, sediment, and nutrient contents of the water. The CRIS also includes an infrared imaging subsystem, which provides information on the temperature of the water. The combination of measurements enables investigation of biological effects of both natural and artificial flows of water from land into the ocean, including diffuse and point-source flows that may contain biological and/or chemical pollutants. Temperature is an important element of such measurements because temperature contrasts can often be used to distinguish among flows from different sources: for example, a sewage outflow could manifest itself in spectral images as a local high-temperature anomaly.

  12. Multi-exposure speckle imaging of cerebral blood flow: a pilot clinical study (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Richards, Lisa M.; Kazmi, S. M. S.; Olin, Katherine E.; Waldron, James S.; Fox, Douglas J.; Dunn, Andrew K.

    2017-03-01

    Monitoring cerebral blood flow (CBF) during neurosurgery is essential for detecting ischemia in a timely manner for a wide range of procedures. Multiple clinical studies have demonstrated that laser speckle contrast imaging (LSCI) has high potential to be a valuable, label-free CBF monitoring technique during neurosurgery. LSCI is an optical imaging method that provides blood flow maps with high spatiotemporal resolution requiring only a coherent light source, a lens system, and a camera. However, the quantitative accuracy and sensitivity of LSCI is limited and highly dependent on the exposure time. An extension to LSCI called multi-exposure speckle imaging (MESI) overcomes these limitations, and was evaluated intraoperatively in patients undergoing brain tumor resection. This clinical study (n = 7) recorded multiple exposure times from the same cortical tissue area, and demonstrates that shorter exposure times (≤1 ms) provide the highest dynamic range and sensitivity for sampling flow rates in human neurovasculature. This study also combined exposure times using the MESI model, demonstrating high correlation with proper image calibration and acquisition. The physiological accuracy of speckle-estimated flow was validated using conservation of flow analysis on vascular bifurcations. Flow estimates were highly conserved in MESI and 1 ms exposure LSCI, with percent errors at 6.4% ± 5.3% and 7.2% ± 7.2%, respectively, while 5 ms exposure LSCI had higher errors at 21% ± 10% (n = 14 bifurcations). Results from this study demonstrate the importance of exposure time selection for LSCI, and that intraoperative MESI can be performed with high quantitative accuracy.

  13. Simulating Nailfold Capillaroscopy Sequences to Evaluate Algorithms for Blood Flow Estimation

    PubMed Central

    Tresadern, P. A.; Berks, M.; Murray, A. K.; Dinsdale, G.; Taylor, C. J.; Herrick, A. L.

    2016-01-01

    The effects of systemic sclerosis (SSc) – a disease of the connective tissue causing blood flow problems that can require amputation of the fingers – can be observed indirectly by imaging the capillaries at the nailfold, though taking quantitative measures such as blood flow to diagnose the disease and monitor its progression is not easy. Optical flow algorithms may be applied, though without ground truth (i.e. known blood flow) it is hard to evaluate their accuracy. We propose an image model that generates realistic capillaroscopy videos with known flow, and use this model to quantify the effect of flow rate, cell density and contrast (among others) on estimated flow. This resource will help researchers to design systems that are robust under real-world conditions. PMID:24110268

  14. Doppler Optical Coherence Tomography

    NASA Astrophysics Data System (ADS)

    Chen, Zhongping; Zhang, Jun

    Noninvasive techniques for imaging in vivo blood flow are of great value to biomedical research and clinical diagnostics where many diseases have a vascular etiology or component. In ophthalmology, many diseases involve disturbances in ocular blood flow, including diabetic retinopathy, low tension glaucoma, anterior ischemic optic neuritis, and macular degeneration. Simultaneous imaging of tissue structure and blood flow could provide critical information for early diagnosis of ocular diseases.

  15. New devices for flow measurements: Hot film and burial wire sensors, infrared imagery, liquid crystal, and piezo-electric model

    NASA Technical Reports Server (NTRS)

    Mcree, Griffith J., Jr.; Roberts, A. Sidney, Jr.

    1991-01-01

    An experimental program aimed at identifying areas in low speed aerodynamic research where infrared imaging systems can make significant contributions is discussed. Implementing a new technique, a long electrically heated wire was placed across a laminar flow. By measuring the temperature distribution along the wire with the IR imaging camera, the flow behavior was identified.

  16. Analysis of structural relationship among the occupational dysfunction on the psychological problem in healthcare workers: a study using structural equation modeling

    PubMed Central

    Kyougoku, Makoto

    2015-01-01

    Purpose. The purpose of this study is to demonstrate the hypothetical model based on structural relationship with the occupational dysfunction on psychological problems (stress response, burnout syndrome, and depression) in healthcare workers. Method. Three cross sectional studies were conducted to assess the following relations: (1) occupational dysfunction on stress response (n = 468), (2) occupational dysfunction on burnout syndrome (n = 1,142), and (3) occupational dysfunction on depression (n = 687). Personal characteristics were collected through a questionnaire (such as age, gender, and job category, opportunities for refreshment, time spent on leisure activities, and work relationships) as well as the Classification and Assessment of Occupational Dysfunction (CAOD). Furthermore, study 1 included the Stress Response Scale-18 (SRS-18), study 2 used the Japanese Burnout Scale (JBS), and study 3 employed the Center for Epidemiological Studies Depression Scale (CES-D). The Kolmogorov–Smirnov test, confirmatory factor analysis (CFA), exploratory factor analysis (EFA), and path analysis of structural equation modeling (SEM) analysis were used in all of the studies. EFA and CFA were used to measure structural validity of four assessments; CAOD, SRS-18, JBS, and CES-D. For examination of a potential covariate, we assessed the correlation of the total and factor score of CAOD and personal factors in all studies. Moreover, direct and indirect effects of occupational dysfunction on stress response (Study 1), burnout syndrome (Study 2), and depression (Study 3) were also analyzed. Results. In study 1, CAOD had 16 items and 4 factors. In Study 2 and 3, CAOD had 16 items and 5 factors. SRS-18 had 18 items and 3 factors, JBS had 17 items and 3 factors, and CES-D had 20 items and 4 factors. All studies found that there were significant correlations between the CAOD total score and the personal factor that included opportunities for refreshment, time spent on leisure activities, and work relationships (p < 0.01). The hypothesis model results suggest that the classification of occupational dysfunction had good fit on the stress response (RMSEA = 0.061, CFI = 0.947, and TLI = 0.943), burnout syndrome (RMSEA = 0.076, CFI = 0.919, and TLI = 0.913), and depression (RMSEA = 0.060, CFI = 0.922, TLI = 0.917). Moreover, the detected covariates include opportunities for refreshment, time spent on leisure activities, and work relationships on occupational dysfunction. Conclusion. Our findings indicate that psychological problems are associated with occupational dysfunction in healthcare workers. Reduction of occupational dysfunction might be a strategy of better preventive occupational therapies for healthcare workers with psychological problems. However, longitudinal studies will be needed to determine a causal relationship. PMID:26618078

  17. Analysis of structural relationship among the occupational dysfunction on the psychological problem in healthcare workers: a study using structural equation modeling.

    PubMed

    Teraoka, Mutsumi; Kyougoku, Makoto

    2015-01-01

    Purpose. The purpose of this study is to demonstrate the hypothetical model based on structural relationship with the occupational dysfunction on psychological problems (stress response, burnout syndrome, and depression) in healthcare workers. Method. Three cross sectional studies were conducted to assess the following relations: (1) occupational dysfunction on stress response (n = 468), (2) occupational dysfunction on burnout syndrome (n = 1,142), and (3) occupational dysfunction on depression (n = 687). Personal characteristics were collected through a questionnaire (such as age, gender, and job category, opportunities for refreshment, time spent on leisure activities, and work relationships) as well as the Classification and Assessment of Occupational Dysfunction (CAOD). Furthermore, study 1 included the Stress Response Scale-18 (SRS-18), study 2 used the Japanese Burnout Scale (JBS), and study 3 employed the Center for Epidemiological Studies Depression Scale (CES-D). The Kolmogorov-Smirnov test, confirmatory factor analysis (CFA), exploratory factor analysis (EFA), and path analysis of structural equation modeling (SEM) analysis were used in all of the studies. EFA and CFA were used to measure structural validity of four assessments; CAOD, SRS-18, JBS, and CES-D. For examination of a potential covariate, we assessed the correlation of the total and factor score of CAOD and personal factors in all studies. Moreover, direct and indirect effects of occupational dysfunction on stress response (Study 1), burnout syndrome (Study 2), and depression (Study 3) were also analyzed. Results. In study 1, CAOD had 16 items and 4 factors. In Study 2 and 3, CAOD had 16 items and 5 factors. SRS-18 had 18 items and 3 factors, JBS had 17 items and 3 factors, and CES-D had 20 items and 4 factors. All studies found that there were significant correlations between the CAOD total score and the personal factor that included opportunities for refreshment, time spent on leisure activities, and work relationships (p < 0.01). The hypothesis model results suggest that the classification of occupational dysfunction had good fit on the stress response (RMSEA = 0.061, CFI = 0.947, and TLI = 0.943), burnout syndrome (RMSEA = 0.076, CFI = 0.919, and TLI = 0.913), and depression (RMSEA = 0.060, CFI = 0.922, TLI = 0.917). Moreover, the detected covariates include opportunities for refreshment, time spent on leisure activities, and work relationships on occupational dysfunction. Conclusion. Our findings indicate that psychological problems are associated with occupational dysfunction in healthcare workers. Reduction of occupational dysfunction might be a strategy of better preventive occupational therapies for healthcare workers with psychological problems. However, longitudinal studies will be needed to determine a causal relationship.

  18. Flip-flop method: A new T1-weighted flow-MRI for plants studies.

    PubMed

    Buy, Simon; Le Floch, Simon; Tang, Ning; Sidiboulenouar, Rahima; Zanca, Michel; Canadas, Patrick; Nativel, Eric; Cardoso, Maida; Alibert, Eric; Dupont, Guillaume; Ambard, Dominique; Maurel, Christophe; Verdeil, Jean-Luc; Bertin, Nadia; Goze-Bac, Christophe; Coillot, Christophe

    2018-01-01

    The climate warming implies an increase of stress of plants (drought and torrential rainfall). The understanding of plant behavior, in this context, takes a major importance and sap flow measurement in plants remains a key issue for plant understanding. Magnetic Resonance Imaging (MRI) which is well known to be a powerful tool to access water quantity can be used to measure moving water. We describe a novel flow-MRI method which takes advantage of inflow slice sensitivity. The method involves the slice selectivity in the context of multi slice spin echo sequence. Two sequences such as a given slice is consecutively inflow and outflow sensitive are performed, offering the possiblility to perform slow flow sensitive imaging in a quite straigthforward way. The method potential is demonstrated by imaging both a slow flow measurement on a test bench (as low as 10 μm.s-1) and the Poiseuille's profile of xylemian sap flow velocity in the xylematic tissues of a tomato plant stem.

  19. Quantitative Image Analysis Techniques with High-Speed Schlieren Photography

    NASA Technical Reports Server (NTRS)

    Pollard, Victoria J.; Herron, Andrew J.

    2017-01-01

    Optical flow visualization techniques such as schlieren and shadowgraph photography are essential to understanding fluid flow when interpreting acquired wind tunnel test data. Output of the standard implementations of these visualization techniques in test facilities are often limited only to qualitative interpretation of the resulting images. Although various quantitative optical techniques have been developed, these techniques often require special equipment or are focused on obtaining very precise and accurate data about the visualized flow. These systems are not practical in small, production wind tunnel test facilities. However, high-speed photography capability has become a common upgrade to many test facilities in order to better capture images of unsteady flow phenomena such as oscillating shocks and flow separation. This paper describes novel techniques utilized by the authors to analyze captured high-speed schlieren and shadowgraph imagery from wind tunnel testing for quantification of observed unsteady flow frequency content. Such techniques have applications in parametric geometry studies and in small facilities where more specialized equipment may not be available.

  20. Cerebrospinal fluid bulk flow is driven by the cardiac cycle

    NASA Astrophysics Data System (ADS)

    Tithof, Jeffrey; Mestre, Humberto; Thomas, John; Nedergaard, Maiken; Kelley, Douglas

    2017-11-01

    Recent discoveries have uncovered a cerebrospinal fluid (CSF) transport system in the perivascular spaces (PVS) of the mammalian brain which clears excess extracellular fluid and protein waste products. The oscillatory pattern of CSF flow has long been attributed to arterial pulsations due to cardiac contractility but limitations in imaging techniques have impeded quantitative measurement of flow rates within the PVS. In this talk, we describe quantitative measurements from the first ever direct imaging of CSF flow in the PVS of a mouse brain. We perform particle tracking velocimetry to obtain time-resolved velocity measurements. To identify the cardiac and/or respiratory dependence of the flow, while imaging, we simultaneously record the mouse's electrocardiogram and respiration. Our measurements conclusively indicate that CSF pulsatility in the arterial PVS is directly driven by the cardiac cycle and not by the respiratory cycle or cerebral vasomotion. These results offer a substantial step forward in understanding bulk flow of CSF in the mammalian brain and may have important implications related to neurodegenerative diseases.

  1. General phase regularized reconstruction using phase cycling.

    PubMed

    Ong, Frank; Cheng, Joseph Y; Lustig, Michael

    2018-07-01

    To develop a general phase regularized image reconstruction method, with applications to partial Fourier imaging, water-fat imaging and flow imaging. The problem of enforcing phase constraints in reconstruction was studied under a regularized inverse problem framework. A general phase regularized reconstruction algorithm was proposed to enable various joint reconstruction of partial Fourier imaging, water-fat imaging and flow imaging, along with parallel imaging (PI) and compressed sensing (CS). Since phase regularized reconstruction is inherently non-convex and sensitive to phase wraps in the initial solution, a reconstruction technique, named phase cycling, was proposed to render the overall algorithm invariant to phase wraps. The proposed method was applied to retrospectively under-sampled in vivo datasets and compared with state of the art reconstruction methods. Phase cycling reconstructions showed reduction of artifacts compared to reconstructions without phase cycling and achieved similar performances as state of the art results in partial Fourier, water-fat and divergence-free regularized flow reconstruction. Joint reconstruction of partial Fourier + water-fat imaging + PI + CS, and partial Fourier + divergence-free regularized flow imaging + PI + CS were demonstrated. The proposed phase cycling reconstruction provides an alternative way to perform phase regularized reconstruction, without the need to perform phase unwrapping. It is robust to the choice of initial solutions and encourages the joint reconstruction of phase imaging applications. Magn Reson Med 80:112-125, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  2. Shaded computer graphic techniques for visualizing and interpreting analytic fluid flow models

    NASA Technical Reports Server (NTRS)

    Parke, F. I.

    1981-01-01

    Mathematical models which predict the behavior of fluid flow in different experiments are simulated using digital computers. The simulations predict values of parameters of the fluid flow (pressure, temperature and velocity vector) at many points in the fluid. Visualization of the spatial variation in the value of these parameters is important to comprehend and check the data generated, to identify the regions of interest in the flow, and for effectively communicating information about the flow to others. The state of the art imaging techniques developed in the field of three dimensional shaded computer graphics is applied to visualization of fluid flow. Use of an imaging technique known as 'SCAN' for visualizing fluid flow, is studied and the results are presented.

  3. A High Performance Pulsatile Pump for Aortic Flow Experiments in 3-Dimensional Models.

    PubMed

    Chaudhury, Rafeed A; Atlasman, Victor; Pathangey, Girish; Pracht, Nicholas; Adrian, Ronald J; Frakes, David H

    2016-06-01

    Aortic pathologies such as coarctation, dissection, and aneurysm represent a particularly emergent class of cardiovascular diseases. Computational simulations of aortic flows are growing increasingly important as tools for gaining understanding of these pathologies, as well as for planning their surgical repair. In vitro experiments are required to validate the simulations against real world data, and the experiments require a pulsatile flow pump system that can provide physiologic flow conditions characteristic of the aorta. We designed a newly capable piston-based pulsatile flow pump system that can generate high volume flow rates (850 mL/s), replicate physiologic waveforms, and pump high viscosity fluids against large impedances. The system is also compatible with a broad range of fluid types, and is operable in magnetic resonance imaging environments. Performance of the system was validated using image processing-based analysis of piston motion as well as particle image velocimetry. The new system represents a more capable pumping solution for aortic flow experiments than other available designs, and can be manufactured at a relatively low cost.

  4. Development of a custom-designed echo particle image velocimetry system for multi-component hemodynamic measurements: system characterization and initial experimental results

    NASA Astrophysics Data System (ADS)

    Liu, Lingli; Zheng, Hairong; Williams, Logan; Zhang, Fuxing; Wang, Rui; Hertzberg, Jean; Shandas, Robin

    2008-03-01

    We have recently developed an ultrasound-based velocimetry technique, termed echo particle image velocimetry (Echo PIV), to measure multi-component velocity vectors and local shear rates in arteries and opaque fluid flows by identifying and tracking flow tracers (ultrasound contrast microbubbles) within these flow fields. The original system was implemented on images obtained from a commercial echocardiography scanner. Although promising, this system was limited in spatial resolution and measurable velocity range. In this work, we propose standard rules for characterizing Echo PIV performance and report on a custom-designed Echo PIV system with increased spatial resolution and measurable velocity range. Then we employed this system for initial measurements on tube flows, rotating flows and in vitro carotid artery and abdominal aortic aneurysm (AAA) models to acquire the local velocity and shear rate distributions in these flow fields. The experimental results verified the accuracy of this technique and indicated the promise of the custom Echo PIV system in capturing complex flow fields non-invasively.

  5. Extended depth of field imaging for high speed object analysis

    NASA Technical Reports Server (NTRS)

    Frost, Keith (Inventor); Ortyn, William (Inventor); Basiji, David (Inventor); Bauer, Richard (Inventor); Liang, Luchuan (Inventor); Hall, Brian (Inventor); Perry, David (Inventor)

    2011-01-01

    A high speed, high-resolution flow imaging system is modified to achieve extended depth of field imaging. An optical distortion element is introduced into the flow imaging system. Light from an object, such as a cell, is distorted by the distortion element, such that a point spread function (PSF) of the imaging system is invariant across an extended depth of field. The distorted light is spectrally dispersed, and the dispersed light is used to simultaneously generate a plurality of images. The images are detected, and image processing is used to enhance the detected images by compensating for the distortion, to achieve extended depth of field images of the object. The post image processing preferably involves de-convolution, and requires knowledge of the PSF of the imaging system, as modified by the optical distortion element.

  6. Stereoscopic Imaging in Hypersonics Boundary Layers using Planar Laser-Induced Fluorescence

    NASA Technical Reports Server (NTRS)

    Danehy, Paul M.; Bathel, Brett; Inman, Jennifer A.; Alderfer, David W.; Jones, Stephen B.

    2008-01-01

    Stereoscopic time-resolved visualization of three-dimensional structures in a hypersonic flow has been performed for the first time. Nitric Oxide (NO) was seeded into hypersonic boundary layer flows that were designed to transition from laminar to turbulent. A thick laser sheet illuminated and excited the NO, causing spatially-varying fluorescence. Two cameras in a stereoscopic configuration were used to image the fluorescence. The images were processed in a computer visualization environment to provide stereoscopic image pairs. Two methods were used to display these image pairs: a cross-eyed viewing method which can be viewed by naked eyes, and red/blue anaglyphs, which require viewing through red/blue glasses. The images visualized three-dimensional information that would be lost if conventional planar laser-induced fluorescence imaging had been used. Two model configurations were studied in NASA Langley Research Center's 31-Inch Mach 10 Air Wind tunnel. One model was a 10 degree half-angle wedge containing a small protuberance to force the flow to transition. The other model was a 1/3-scale, truncated Hyper-X forebody model with blowing through a series of holes to force the boundary layer flow to transition to turbulence. In the former case, low flowrates of pure NO seeded and marked the boundary layer fluid. In the latter, a trace concentration of NO was seeded into the injected N2 gas. The three-dimensional visualizations have an effective time resolution of about 500 ns, which is fast enough to freeze this hypersonic flow. The 512x512 resolution of the resulting images is much higher than high-speed laser-sheet scanning systems with similar time response, which typically measure 10-20 planes.

  7. [Carotid plaque assessment using inversion recovery T1 weighted-3 dimensions variable refocus flip angle turbo spin echo sampling perfection with application optimized contrast using different angle evolutions black blood imaging].

    PubMed

    Inoue, Yuji; Yoneyama, Masami; Nakamura, Masanobu; Ozaki, Satoshi; Ito, Kenjiro; Hiura, Mikio

    2012-01-01

    Vulnerable plaque can be attributed to induction of ischemic symptoms and magnetic resonance imaging of carotid artery is valuable to detect the plaque. Magnetization prepared rapid acquisition with gradient echo (MPRAGE) method could detect hemorrhagic vulnerable plaque as high intensity signal; however, blood flow is not sufficiently masked by this method. The contrast for plaque in T1 weighted image (T1WI) could not be obtained sufficiently with black blood image (BBI) by sampling perfection with application optimized contrast using different angle evolutions (SPACE) method as turbo spin echo (TSE). In addition, an appearance of artifact by slow flow is a problem. Considering these controversial situations in plaque imaging, we examined the modified BBI inversion recovery (IR)-SPACE in which IR was added for SPACE method so that the contrast for plaque in T1WI was optimized. We investigated the application of this method in plaque imaging. As a result of phantom imaging, the contrast for plaque in T1WI was definitely obtained by choosing an appropriate inversion time (TI) for the corresponding repetition time. In clinical cases, blood flow was sufficiently masked by IR-SPACE method and the plaque imaging was clearly obtained in clinical cases to the same extent as MPRAGE method. Since BBI with IR-SPACE method was derived from both IR pulse and flow void effect, this method could obtain the blood flow masking effect definitely. The present study suggested that SPACE method might be applicable to estimate properties of carotid artery plaque.

  8. Application of Particle Image Velocimetry and Reference Image Topography to jet shock cells using the hydraulic analogy

    NASA Astrophysics Data System (ADS)

    Kumar, Vaibhav; Ng, Ivan; Sheard, Gregory J.; Brocher, Eric; Hourigan, Kerry; Fouras, Andreas

    2011-08-01

    This paper examines the shock cell structure, vorticity and velocity field at the exit of an underexpanded jet nozzle using a hydraulic analogy and the Reference Image Topography technique. Understanding the flow in this region is important for the mitigation of screech, an aeroacoustic problem harmful to aircraft structures. Experiments are conducted on a water table, allowing detailed quantitative investigation of this important flow regime at a greatly reduced expense. Conventional Particle Image Velocimetry is employed to determine the velocity and vorticity fields of the nozzle exit region. Applying Reference Image Topography, the wavy water surface is reconstructed and when combined with the hydraulic analogy, provides a pressure map of the region. With this approach subtraction of surfaces is used to highlight the unsteady regions of the flow, which is not as convenient or quantitative with conventional Schlieren techniques. This allows a detailed analysis of the shock cell structures and their interaction with flow instabilities in the shear layer that are the underlying cause of jet screech.

  9. Preliminary evaluation of cryogenic two-phase flow imaging using electrical capacitance tomography

    NASA Astrophysics Data System (ADS)

    Xie, Huangjun; Yu, Liu; Zhou, Rui; Qiu, Limin; Zhang, Xiaobin

    2017-09-01

    The potential application of the 2-D eight-electrode electrical capacitance tomography (ECT) to the inversion imaging of the liquid nitrogen-vaporous nitrogen (LN2-VN2) flow in the tube is theoretically evaluated. The phase distribution of the computational domain is obtained using the simultaneous iterative reconstruction technique with variable iterative step size. The detailed mathematical derivations for the calculations are presented. The calculated phase distribution for the two detached LN2 column case shows the comparable results with the water-air case, regardless of the much reduced dielectric permittivity of LN2 compared with water. The inversion images of total eight different LN2-VN2 flow patterns are presented and quantitatively evaluated by calculating the relative void fraction error and the correlation coefficient. The results demonstrate that the developed reconstruction technique for ECT has the capacity to reconstruct the phase distribution of the complex LN2-VN2 flow, while the accuracy of the inversion images is significantly influenced by the size of the discrete phase. The influence of the measurement noise on the image quality is also considered in the calculations.

  10. Super resolution PLIF demonstrated in turbulent jet flows seeded with I2

    NASA Astrophysics Data System (ADS)

    Xu, Wenjiang; Liu, Ning; Ma, Lin

    2018-05-01

    Planar laser induced fluorescence (PLIF) represents an indispensable tool for flow and flame imaging. However, the PLIF technique suffers from limited spatial resolution or blurring in many situations, which restricts its applicability and capability. This work describes a new method, named SR-PLIF (super-resolution PLIF), to overcome these limitations and enhance the capability of PLIF. The method uses PLIF images captured simultaneously from two (or more) orientations to reconstruct a final PLIF image with resolution enhanced or blurring removed. This paper reports the development of the reconstruction algorithm, and the experimental demonstration of the SR-PLIF method both with controlled samples and with turbulent flows seeded with iodine vapor. Using controlled samples with two cameras, the spatial resolution in the best case was improved from 0.06 mm in the projections to 0.03 mm in the SR image, in terms of the spreading width of a sharp edge. With turbulent flows, an image sharpness measure was developed to quantify the spatial resolution, and SR reconstruction with two cameras can effectively improve the spatial resolution compared to the projections in terms of the sharpness measure.

  11. IR imaging of blood circulation of patients with vascular disease

    NASA Astrophysics Data System (ADS)

    Wang, Hsin; Wade, Dwight R., Jr.; Kam, Jack

    2004-04-01

    We conducted a preliminary IR imaging study of blood circulation in patients with peripheral vascular diseases. Abnormal blood flow is common in older adults, especially those with elevated blood lipids, diabetes, hypertension, and a history of smoking. All of these conditions have a high prevalence in our population, often with more than one condition in the same individual. The differences in blood flow is revealed by temperature differences in areas of the extremities as well as other regions of the body. However, what is needed is an imaging technique that is relatively inexpensive and can reveal the blood flow in real time. The IR imaging can show detailed venous system and small tempearture changes associated with blood flow. Six patients with vascular diseases were tested in a clinic set up. Their legs and feet were imaged. We observed large temperature differences (cooling of more than 10° C) at the foot, especially toes. More valuable information were obtained from the temperature distribution maps. IR thermography is potentially a very valuable tool for medical application, especially for vascular diseases.

  12. Imaging lung perfusion

    PubMed Central

    Wielpütz, Mark O.; Kauczor, Hans-Ulrich

    2012-01-01

    From the first measurements of the distribution of pulmonary blood flow using radioactive tracers by West and colleagues (J Clin Invest 40: 1–12, 1961) allowing gravitational differences in pulmonary blood flow to be described, the imaging of pulmonary blood flow has made considerable progress. The researcher employing modern imaging techniques now has the choice of several techniques, including magnetic resonance imaging (MRI), computerized tomography (CT), positron emission tomography (PET), and single photon emission computed tomography (SPECT). These techniques differ in several important ways: the resolution of the measurement, the type of contrast or tag used to image flow, and the amount of ionizing radiation associated with each measurement. In addition, the techniques vary in what is actually measured, whether it is capillary perfusion such as with PET and SPECT, or larger vessel information in addition to capillary perfusion such as with MRI and CT. Combined, these issues affect quantification and interpretation of data as well as the type of experiments possible using different techniques. The goal of this review is to give an overview of the techniques most commonly in use for physiological experiments along with the issues unique to each technique. PMID:22604884

  13. High-Speed PLIF Imaging of Hypersonic Transition over Discrete Cylindrical Roughness

    NASA Technical Reports Server (NTRS)

    Danehy, P. M.; Ivey, C. B.; Inman, J. A.; Bathel, B. F.; Jones, S. B.; McCrea, A. C.; Jiang, N.; Webster, M.; Lempert, W.; Miller, J.; hide

    2010-01-01

    In two separate test entries, advanced laser-based instrumentation has been developed and applied to visualize the hypersonic flow over cylindrical protrusions on a flat plate. Upstream of these trips, trace quantities of nitric oxide (NO) were seeded into the boundary layer. The protuberances were sized to force laminar-to-turbulent boundary layer transition. In the first test, a 10-Hz nitric oxide planar laser-induced fluorescence (NO PLIF) flow visualization system was used to provide wide-field-of-view, high-resolution images of the flowfield. The images had sub-microsecond time resolution. However these images, obtained with a time separation of 0.1 sec, were uncorrelated with each other. Fluorescent oil-flow visualizations were also obtained during this test. In the second experiment, a laser and camera system capable of acquiring NO PLIF measurements at 1 million frames per second (1 MHz) was used. This system had lower spatial resolution, and a smaller field of view, but the images were time correlated so that the development of the flow structures could be observed in time.

  14. In Vivo Myeloperoxidase Imaging and Flow Cytometry Analysis of Intestinal Myeloid Cells.

    PubMed

    Hülsdünker, Jan; Zeiser, Robert

    2016-01-01

    Myeloperoxidase (MPO) imaging is a non-invasive method to detect cells that produce the enzyme MPO that is most abundant in neutrophils, macrophages, and inflammatory monocytes. While lacking specificity for any of these three cell types, MPO imaging can provide guidance for further flow cytometry-based analysis of tissues where these cell types reside. Isolation of leukocytes from the intestinal tract is an error-prone procedure. Here, we describe a protocol for intestinal leukocyte isolation that works reliable in our hands and allows for flow cytometry-based analysis, in particular of neutrophils.

  15. Tracking lava flow emplacement on the east rift zone of Kilauea, Hawai'i with InSAR coherence

    NASA Astrophysics Data System (ADS)

    Dietterich, H. R.; Schmidt, D. A.; Poland, M. P.; Cashman, K. V.

    2010-12-01

    Remote sensing of lava flows from the Pu`u `O`o-Kupaianaha eruption on the east rift zone of Kilauea serves to document the ongoing eruption, while yielding insights into how lava flow fields develop. InSAR is widely used to measure deformation by detecting minute changes in ground surfaces that stay correlated during repeat observations. The eruption and emplacement of fresh lava on the surface, however, disrupts the coherence of the radar echoes, allowing the area of these flows to be mapped with InSAR coherence images. We use InSAR correlation to visualize surface flow activity from 2003-2010 in order to quantify eruption rates and explore lava flow behavior from emplacement onward. This method for mapping flows does not require daylight, cloudless skies, or access to the active flow fields that is necessary for traditional visual surveys. We produce coherence maps for hundreds of 35 to 105-day periods from twelve tracks of ENVISAT SAR data using the GAMMA software package. By combining these coherence maps we create a unique dataset with which to develop this technique and amass lava flow observations. Where correlation images overlap in time, they are summed and normalized to derive a time series of surface coherence with a spatial resolution of 20 meters and a temporal resolution of as little as a few days. We identify existing stable flows by their high radar coherence, and determine a coherence threshold that is applied to each correlation image. This threshold is calibrated so as to reduce the effects of varying baseline, time duration, and atmospheric effects between images, as well as decorrelation due to vegetation. The final images illustrate lava flow activity that corresponds well with surface flow outlines and tube locations recorded by the USGS mapping effort. The InSAR-derived results serve to enhance these traditional maps by documenting pixel-scale changes over time. When compared with forward looking infrared (FLIR) thermal imagery, pixel decorrelation can be related to specific styles of activity, including surface breakouts or deformation, where field examination is difficult. We analyze these detailed snapshots of the flows to derive estimates of flow parameters, including effusion rates, lava flow areas and volumes, and surface lava flow activity over time, which provides a means of examining controls on flow paths, advance rates, and morphologies. We find that once emplaced, flows remain decorrelated for months before becoming correlated again in a piecewise fashion, suggesting that correlation rate may be dependent on thickness and cooling rate. As the eruption continues, this ever-expanding dataset has great potential for remotely capturing quantitative data from an active flow field and improving our knowledge of lava flows and their hazards.

  16. Laser doppler blood flow imaging using a CMOS imaging sensor with on-chip signal processing.

    PubMed

    He, Diwei; Nguyen, Hoang C; Hayes-Gill, Barrie R; Zhu, Yiqun; Crowe, John A; Gill, Cally; Clough, Geraldine F; Morgan, Stephen P

    2013-09-18

    The first fully integrated 2D CMOS imaging sensor with on-chip signal processing for applications in laser Doppler blood flow (LDBF) imaging has been designed and tested. To obtain a space efficient design over 64 × 64 pixels means that standard processing electronics used off-chip cannot be implemented. Therefore the analog signal processing at each pixel is a tailored design for LDBF signals with balanced optimization for signal-to-noise ratio and silicon area. This custom made sensor offers key advantages over conventional sensors, viz. the analog signal processing at the pixel level carries out signal normalization; the AC amplification in combination with an anti-aliasing filter allows analog-to-digital conversion with a low number of bits; low resource implementation of the digital processor enables on-chip processing and the data bottleneck that exists between the detector and processing electronics has been overcome. The sensor demonstrates good agreement with simulation at each design stage. The measured optical performance of the sensor is demonstrated using modulated light signals and in vivo blood flow experiments. Images showing blood flow changes with arterial occlusion and an inflammatory response to a histamine skin-prick demonstrate that the sensor array is capable of detecting blood flow signals from tissue.

  17. A Bayesian Model for Highly Accelerated Phase-Contrast MRI

    PubMed Central

    Rich, Adam; Potter, Lee C.; Jin, Ning; Ash, Joshua; Simonetti, Orlando P.; Ahmad, Rizwan

    2015-01-01

    Purpose Phase-contrast magnetic resonance imaging (PC-MRI) is a noninvasive tool to assess cardiovascular disease by quantifying blood flow; however, low data acquisition efficiency limits the spatial and temporal resolutions, real-time application, and extensions to 4D flow imaging in clinical settings. We propose a new data processing approach called Reconstructing Velocity Encoded MRI with Approximate message passing aLgorithms (ReVEAL) that accelerates the acquisition by exploiting data structure unique to PC-MRI. Theory and Methods ReVEAL models physical correlations across space, time, and velocity encodings. The proposed Bayesian approach exploits the relationships in both magnitude and phase among velocity encodings. A fast iterative recovery algorithm is introduced based on message passing. For validation, prospectively undersampled data are processed from a pulsatile flow phantom and five healthy volunteers. Results ReVEAL is in good agreement, quantified by peak velocity and stroke volume (SV), with reference data for acceleration rates R ≤ 10. For SV, Pearson r ≥ 0.996 for phantom imaging (n = 24) and r ≥ 0.956 for prospectively accelerated in vivo imaging (n = 10) for R ≤ 10. Conclusion ReVEAL enables accurate quantification of blood flow from highly undersampled data. The technique is extensible to 4D flow imaging, where higher acceleration may be possible due to additional redundancy. PMID:26444911

  18. Noncontact diffuse correlation tomography of human breast tumor

    PubMed Central

    He, Lian; Lin, Yu; Huang, Chong; Irwin, Daniel; Szabunio, Margaret M.; Yu, Guoqiang

    2015-01-01

    Abstract. Our first step to adapt our recently developed noncontact diffuse correlation tomography (ncDCT) system for three-dimensional (3-D) imaging of blood flow distribution in human breast tumors is reported. A commercial 3-D camera was used to obtain breast surface geometry, which was then converted to a solid volume mesh. An ncDCT probe scanned over a region of interest on the mesh surface and the measured boundary data were combined with a finite element framework for 3-D image reconstruction of blood flow distribution. This technique was tested in computer simulations and in vivo human breasts with low-grade carcinoma. Results from computer simulations suggest that relatively high accuracy can be achieved when the entire tumor is within the sensitive region of diffuse light. Image reconstruction with a priori knowledge of the tumor volume and location can significantly improve the accuracy in recovery of tumor blood flow contrasts. In vivo imaging results from two breast carcinomas show higher average blood flow contrasts (5.9- and 10.9-fold) in the tumor regions compared to the surrounding tissues, which are comparable with previous findings using diffuse correlation spectroscopy. The ncDCT system has the potential to image blood flow distributions in soft and vulnerable tissues without distorting tissue hemodynamics. PMID:26259706

  19. Multi-Velocity Encoding Four-Dimensional Flow Magnetic Resonance Imaging in the Assessment of Chronic Aortic Dissection

    PubMed Central

    Sherrah, Andrew G.; Callaghan, Fraser M.; Puranik, Rajesh; Jeremy, Richmond W.; Bannon, Paul G.; Vallely, Michael P.; Grieve, Stuart M.

    2017-01-01

    Background Chronic descending thoracic aortic dissection (CDTAD) following surgical repair of ascending aortic dissection requires long-term imaging surveillance. We investigated four-dimensional (4D)-flow magnetic resonance imaging (MRI) with a novel multi-velocity encoding (multi-VENC) technique as an emerging clinical method enabling the dynamic quantification of blood volume and velocity throughout the cardiac cycle. Methods Patients with CDTAD (n = 10; mean age, 55.1 years; standard deviation (SD) 10.8) and healthy volunteers (n = 9; mean age, 37.1 years; SD 11.4; p < 0.01) underwent 3T MRI, and standard views and 4D-flow data were obtained. Flow measurements were made in selected regions of interest within the ascending and descending thoracic aorta. Results The overall flow profile at peak systole was reduced in the false lumen (FL) compared with the true lumen (TL) and normal aortas (p < 0.05 for velocity < 0.4 m/s). Peak systolic flow rate per aortic lumen area (mL/s/cm2) was lower in the FL than in the TL (p < 0.05), and both rates were lower than that of control aortas (p < 0.05). Blood flow reversal was higher in the FL than in the TL throughout the descending aorta in CDTAD patients (p < 0.05). A derived pulsatility index was elevated in the TL compared with that in the FL in CDTAD patients. Generated pathline images demonstrated flow patterns in detail, including sites of communication between the true and FL. Conclusions 4D-flow MRI revealed FL blood flow and reduced blood flow velocity and flow rate in the TL of CDTAD patients compared with normal aortas of healthy participants. Thus, multi-VENC 4D-flow MRI could serve as an adjunct in the long-term assessment of CDTAD following surgical repair of ascending aortic dissection. PMID:29675440

  20. Which Way is Up?

    NASA Image and Video Library

    2014-10-29

    This image NASA Mars Reconnaissance Orbiter shows an impact crater that was cut by lava in the Elysium Planitia region of Mars. It looks relatively flat, with a shallow floor, rough surface texture, and possible cooling cracks seem to indicate that the crater was partially filled with lava. The northern part of the image also shows a more extensive lava flow deposit that surrounds the impact ejecta of the largest impact crater in the image. Which way did the lava flow? It might appear that the lava flowed from the north through the channel into the partially filled crater. However, if you look at the anaglyph with your red and blue 3D glasses, it becomes clear that the partially filled crater sits on top of the large crater's ejecta blanket, making it higher than the lava flow to the north. Since lava does not flow uphill, that means the explanation isn't so simple. http://photojournal.jpl.nasa.gov/catalog/PIA18887

Top