Gohean, Jeffrey R; George, Mitchell J; Pate, Thomas D; Kurusz, Mark; Longoria, Raul G; Smalling, Richard W
2013-01-01
The purpose of this investigation is to use a computational model to compare a synchronized valveless pulsatile left ventricular assist device with continuous flow left ventricular assist devices at the same level of device flow, and to verify the model with in vivo porcine data. A dynamic system model of the human cardiovascular system was developed to simulate the support of a healthy or failing native heart from a continuous flow left ventricular assist device or a synchronous pulsatile valveless dual-piston positive displacement pump. These results were compared with measurements made during in vivo porcine experiments. Results from the simulation model and from the in vivo counterpart show that the pulsatile pump provides higher cardiac output, left ventricular unloading, cardiac pulsatility, and aortic valve flow as compared with the continuous flow model at the same level of support. The dynamic system model developed for this investigation can effectively simulate human cardiovascular support by a synchronous pulsatile or continuous flow ventricular assist device.
Gohean, Jeffrey R.; George, Mitchell J.; Pate, Thomas D.; Kurusz, Mark; Longoria, Raul G.; Smalling, Richard W.
2012-01-01
The purpose of this investigation is to utilize a computational model to compare a synchronized valveless pulsatile left ventricular assist device to continuous flow left ventricular assist devices at the same level of device flow, and to verify the model with in vivo porcine data. A dynamic system model of the human cardiovascular system was developed to simulate support of a healthy or failing native heart from a continuous flow left ventricular assist device or a synchronous, pulsatile, valveless, dual piston positive displacement pump. These results were compared to measurements made during in vivo porcine experiments. Results from the simulation model and from the in vivo counterpart show that the pulsatile pump provides higher cardiac output, left ventricular unloading, cardiac pulsatility, and aortic valve flow as compared to the continuous flow model at the same level of support. The dynamic system model developed for this investigation can effectively simulate human cardiovascular support by a synchronous pulsatile or continuous flow ventricular assist device. PMID:23438771
Diastolic heart failure associated with hemangiosarcoma infiltrating left ventricular walls in a dog
Osuga, Tatsuyuki; Nakamura, Kensuke; Morita, Tomoya; Kagawa, Yumiko; Ohta, Hiroshi; Takiguchi, Mitsuyoshi
2017-01-01
A 9-year-old Shetland sheepdog was diagnosed with cardiogenic pulmonary edema. Echocardiography revealed focally thickened left ventricular free wall and interventricular septum and left atrial dilation. Left ventricular systolic function was preserved. Doppler echocardiography of transmitral flow indicated restrictive left ventricular filling. Cardiac histopathology demonstrated hemangiosarcoma infiltrating the left ventricular walls. PMID:29089652
Osuga, Tatsuyuki; Nakamura, Kensuke; Morita, Tomoya; Kagawa, Yumiko; Ohta, Hiroshi; Takiguchi, Mitsuyoshi
2017-11-01
A 9-year-old Shetland sheepdog was diagnosed with cardiogenic pulmonary edema. Echocardiography revealed focally thickened left ventricular free wall and interventricular septum and left atrial dilation. Left ventricular systolic function was preserved. Doppler echocardiography of transmitral flow indicated restrictive left ventricular filling. Cardiac histopathology demonstrated hemangiosarcoma infiltrating the left ventricular walls.
Morales, Maria-Aurora; Neglia, Danilo; L'Abbate, Antonio
2008-08-01
Myocardial blood flow during pharmacological vasodilatation is depressed in patients with idiopathic dilated cardiomyopathy even the in absence of overt heart failure; the extent of myocardial blood flow abnormalities is not predictable by left ventricular ejection fraction (LVEF) and diastolic dimensions. To assess whether myocardial blood flow impairment in idiopathic dilated cardiomyopathy without overt heart failure can be related to Doppler-derived dP/dt and to echocardiographically determined left ventricular end systolic stress - which is linked to myocardial blood flow reserve in advanced disease. Twenty-six patients, New York Heart Association Class I-II, (LVEF 37.4 +/- 1.4%, left ventricular diastolic dimensions 62.6 +/- 0.9 mm) underwent resting/dipyridamole [13N]NH3 flow positron emission tomography and an ultrasonic study. Regional myocardial blood flow values (ml/min per g) were computed from positron emission tomography data in 13 left ventricular (LV) myocardial regions and averaged to provide mean myocardial blood flow and myocardial blood flow reserve, defined as dipyridamole/resting mean myocardial blood flow ratio. Resting myocardial blood flow was 0.686 +/- 0.045, dipyridamole myocardial blood flow 1.39 +/- 0.15 and myocardial blood flow reserve 2.12 +/- 0.2, lower than in controls (P < 0.01). The ratio dP/dt was directly related to dipyridamole myocardial blood flow and myocardial blood flow reserve (r = 0.552 and 0.703, P < 0.005 and P < 0.0001); no relation was found between myocardial blood flow and LVEF left ventricular diastolic dimensions, and left ventricular end systolic stress. In idiopathic dilated cardiomyopathy patients without overt heart failure, the extent of myocardial blood flow reserve impairment is related to dP/dt but not to more classical indices of left ventricular function.
Hasin, Tal; Huebner, Marianne; Li, Zhuo; Brown, Daniel; Stulak, John M; Boilson, Barry A; Joyce, Lyle; Pereira, Naveen L; Kushwaha, Sudhir S; Park, Soon J
2014-01-01
Cardiac output (CO) assessment is important in treating patients with heart failure. Durable left ventricular assist devices (LVADs) provide essentially all CO. In currently used LVADs, estimated device flow is generated by a computerized algorithm. However, LVAD flow estimate may be inaccurate in tracking true CO. We correlated LVAD (HeartMate II) flow with thermodilution CO during postoperative care (day 2-10 after implant) in 81 patients (5,616 paired measurements). Left ventricular assist device flow and CO correlated with a low correlation coefficient (r = 0.42). Left ventricular assist device readings were lower than CO measurements by approximately 0.36 L/min, trending for larger difference with higher values. Left ventricular assist device flow measurements showed less temporal variability compared with CO. Grouping for simultaneous measured blood pressure (BP < 60, 60-70, 70-80, 80-90, and ≥90), the correlation of CO with LVAD flow differed (R = 0.42, 0.67, 0.48, 0.32, 0.32, respectively). Indicating better correlation when mean blood pressure is 60 to 70 mm Hg. Left ventricular assist device flow generally trends with measured CO, but large variability exists, hence flow measures should not be assumed to equal with CO. Clinicians should take into account variables such as high CO, BP, and opening of the aortic valve when interpreting LVAD flow readout. Direct flow sensors incorporated in the LVAD system may allow for better estimation.
The effects of hypoxemia on myocardial blood flow during exercise.
Paridon, S M; Bricker, J T; Dreyer, W J; Reardon, M; Smith, E O; Porter, C B; Michael, L; Fisher, D J
1989-03-01
We evaluated the adequacy of regional and transmural blood flow during exercise and rapid pacing after 1 wk of hypoxemia. Seven mature mongrel dogs were made hypoxemic (mean O2 saturation = 72.4%) by anastomosis of left pulmonary artery to left atrial appendage. Catheters were placed in the left atrium, right atrium, pulmonary artery, and aorta. Atrial and ventricular pacing wires were placed. An aortic flow probe was placed to measure cardiac output. Ten nonshunted dogs, similarly instrumented, served as controls. Recovery time was approximately 1 wk. Cardiac output, mean aortic pressure, and oxygen saturation were measured at rest, with ventricular pacing, atrial pacing, and with treadmill exercise. Ventricular and atrial pace and exercise were at a heart rate of 200. Right ventricular free wall, left ventricular free wall, and septal blood flow were measured with radionuclide-labeled microspheres. Cardiac output, left atrial blood pressure, and aortic blood pressure were similar between the two groups of dogs in all testing states. Myocardial blood flow was significantly higher in the right and left ventricular free wall in the hypoxemic animals during resting and exercise testing states. Myocardial oxygen delivery was similar between the two groups of animals. Pacing resulted in an increase in myocardial blood flow in the control animals but not the hypoxemic animals.(ABSTRACT TRUNCATED AT 250 WORDS)
Ventricular distension and diastolic coronary blood flow in the anaesthetized dog.
Gattullo, D; Linden, R J; Losano, G; Pagliaro, P; Westerhof, N
1993-01-01
There appears to be no agreement as to whether or not an increase in diastolic left ventricular pressure and/or volume can cause a decrease in diastolic coronary blood flow. We investigated the problem in the anaesthetized dog using a flaccid freely distensible latex balloon inserted into the left ventricle with the animal on extracorporeal circulation and the coronary perfusion pressure constant at about 45 mm Hg. Maximal vasodilatation and suppression of autoregulation in coronary vasculature was obtained by the intracoronary infusion of dipyridamole (10-40 mg/h). Ventricular volume was changed in steps of 10 ml from 10 to 70 ml and back to 10 ml, whilst recording coronary blood flow and left ventricular pressure in the left circumflex coronary artery. Over a range of ventricular volumes from 20 to 50 ml and a concomitant rise in diastolic ventricular pressure to about 20 mm Hg there was no change in the diastolic coronary flow. Only when the ventricular volume was more than two times the control value (i.e. exceeded 50 ml) and left ventricular pressure was more than 20 mm Hg, was there a decrease in coronary flow. During the return of the volume to the control level there was a fall in diastolic flow and ventricular contractility with respect to the values obtained when the volume was increased; these two effects were transient lasting less than 10 min. It was not considered that any of the three models of the coronary circulation, waterfall, intramyocardial pump or varying elastance model could explain our results.(ABSTRACT TRUNCATED AT 250 WORDS)
Early signs that predict later haemodynamically significant patent ductus arteriosus.
Engür, Defne; Deveci, Murat; Türkmen, Münevver K
2016-03-01
Our aim was to determine the optimal cut-off values, sensitivity, specificity, and diagnostic power of 12 echocardiographic parameters on the second day of life to predict subsequent ductal patency. We evaluated preterm infants, born at ⩽32 weeks of gestation, starting on their second day of life, and they were evaluated every other day until ductal closure or until there were clinical signs of re-opening. We measured transductal diameter; pulmonary arterial diastolic flow; retrograde aortic diastolic flow; pulsatility index of the left pulmonary artery and descending aorta; left atrium and ventricle/aortic root ratio; left ventricular output; left ventricular flow velocity time integral; mitral early/late diastolic flow; and superior caval vein diameter and flow as well as performed receiver operating curve analysis. Transductal diameter (>1.5 mm); pulmonary arterial diastolic flow (>25.6 cm/second); presence of retrograde aortic diastolic flow; ductal diameter by body weight (>1.07 mm/kg); left pulmonary arterial pulsatility index (⩽0.71); and left ventricle to aortic root ratio (>2.2) displayed high sensitivity and specificity (p0.9). Parameters with moderate sensitivity and specificity were as follows: left atrial to aortic root ratio; left ventricular output; left ventricular flow velocity time integral; and mitral early/late diastolic flow ratio (p0.05) had low diagnostic value. Left pulmonary arterial pulsatility index, left ventricle/aortic root ratio, and ductal diameter by body weight are useful adjuncts offering a broader outlook for predicting ductal patency.
Fisher, E A; Estioko, M R; Stern, E H; Goldman, M E
1987-07-01
Aortic root abscess occurs frequently in aortic prosthetic valve infective endocarditis. The present echocardiographic report documents a ruptured abscess that led to a direct communication between the left ventricular outflow tract and the left atrium confirmed by real-time (color flow) Doppler imaging.
Soucy, Kevin G; Bartoli, Carlo R; Phillips, Dustin; Giridharan, Guruprasad A; Sobieski, Michael A; Wead, William B; Dowling, Robert D; Wu, Zhongjun J; Prabhu, Sumanth D; Slaughter, Mark S; Koenig, Steven C
2017-06-01
Continuous-flow left ventricular assist devices (CF LVADs) are rotary blood pumps that improve mean blood flow, but with potential limitations of non-physiological ventricular volume unloading and diminished vascular pulsatility. In this study, we tested the hypothesis that left ventricular unloading with increasing CF LVAD flow increases myocardial flow normalized to left ventricular work. Healthy (n = 8) and chronic ischemic heart failure (IHF, n = 7) calves were implanted with CF LVADs. Acute hemodynamics and regional myocardial blood flow were measured during baseline (LVAD off, clamped), partial (2-4 L/min) and full (>4 L/min) LVAD support. IHF calves demonstrated greater reduction of cardiac energy demand with increasing LVAD support compared to healthy calves, as calculated by rate-pressure product. Coronary artery flows (p < 0.05) and myocardial blood flow (left ventricle (LV) epicardium and myocardium, p < 0.05) decreased with increasing LVAD support in normal calves. In the IHF model, blood flow to the septum, LV, LV epicardium, and LV myocardium increased significantly with increasing LVAD support when normalized to cardiac energy demand (p < 0.05). In conclusion, myocardial blood flow relative to cardiac demand significantly increased in IHF calves, thereby demonstrating that CF LVAD unloading effectively improves cardiac supply and demand ratio in the setting of ischemic heart failure.
Hemodynamics on abrupt stoppage of centrifugal pumps during left ventricular assist.
Kono, S; Nishimura, K; Nishina, T; Akamatsu, T; Komeda, M
2000-01-01
A magnetically suspended centrifugal pump (MSCP), developed for long-term ventricular assist, is reliable and durable because it has no shaft or seal. However, with nonvalve pumps such as a MSCP, regurgitation occurs when they accidentally stop without cannula clamping. We investigated the hemodynamics during temporary stoppage of a MSCP being used as a left ventricular assist system (LVAS), comparing two inflow cannulation sites. In four sheep (weight, 35-45 kg), microspheres were injected into the left main coronary artery to induce heart failure. An outflow cannula was sutured onto the descending aorta, and two inflow cannulae were inserted into the left atrium and the left ventricle. The MSCP was stopped with both the left ventricular cannula and left atrial cannula clamped, and the hemodynamics and P-V loops were recorded. Each cannula was then unclamped in order, and similar parameters were recorded. LVEDP increased at unclamping of the left ventricular cannula (ULVC), and rose further at unclamping of the left atrial cannula (ULAC). Aortic pressure did not change at ULVC, but decreased at ULAC. The effective systemic flow that subtracted the regurgitant flow through the MSCP from left ventricular output was half at ULVC and almost 0 at ULAC. When stopping centrifugal pumps without circuit clamping, hemodynamic deterioration is less at ULVC than at ULAC. This finding suggests that left ventricular inflow cannulation is recommended to allow more time in emergency situations.
Coronary bypass flow during use of intraaortic balloon pumping and left ventricular assist device.
Tedoriya, T; Kawasuji, M; Sakakibara, N; Takemura, H; Watanabe, Y; Hetzer, R
1998-08-01
Intraaortic balloon pumping (IABP) and left ventricular assist device (LVAD) are used for left ventricular support when low cardiac output occurs after a coronary bypass operation for serious coronary artery disease. There are hemodynamic differences in blood flow in various kinds of coronary artery bypass grafts, caused by their inherent physiologic characteristics. The hemodynamic effects of left ventricular assistance with IABP and LVAD on blood flow through various coronary artery bypass grafts were investigated. An ascending aorta-coronary bypass graft (ACB), an internal thoracic artery, and a descending aorta-coronary bypass graft were anastomosed to the left anterior descending coronary artery in a canine model. In this experimental model, the blood flow to the same coronary bed in the three types of grafts could be evaluated. Blood flow in the left anterior descending coronary artery through the three types of coronary bypass grafts was studied in this model during or in the absence of ventricular assistance. In the control study, the systolic blood flow did not differ among the three types of grafts, but the diastolic flow decreased in the following order: with the ACB, the internal thoracic artery, and the descending aorta-coronary bypass graft. The systolic flow during IABP and LVAD was similar to the control flows. Use of IABP increased the diastolic flow by 75.3%+/-12.4% of the control value in the ACB, 37.9%+/-25.0% in the internal thoracic artery, and 21.2%+/-11.4% in the descending aorta-coronary bypass graft. The LVAD increased the diastolic flow by 97.7%+/-18.7% of the control value in the ACB, 64.5%+/-25.7% in the internal thoracic artery, and 63.0%+/-27.9% in the descending aorta-coronary bypass graft. The diastolic blood flows in the left anterior descending coronary artery and the three types of grafts were significantly greater with IABP than the control values, and significantly greater with LVAD than with IABP and the control values. The degrees of increase of diastolic flows in the left anterior descending coronary artery and the ACB with IABP and LVAD were significantly greater than in the arterial grafts (p < 0.01). The diastolic flows in the internal thoracic artery and descending aorta-coronary bypass graft increased less than in the native left anterior descending coronary artery and ACB during left ventricular assistance, particularly with IABP. It is important for the selection of tactics for the management of catastrophic status after coronary bypass grafting to consider the hemodynamic characteristics of the graft.
Sharif, Dawod; Abu-Salem, Mira; Sharif-Rasslan, Amal; Rosenschein, Uri
2017-10-01
Patients with acute ST-elevation myocardial infarction (STEMI) and increased platelet count treated by fibrinolysis have worse outcomes. The aim of this study was to test the hypothesis that platelet blood count at admission in patients with acute STEMI treated by primary percutaneous coronary intervention affects coronary flow, myocardial perfusion and recovery of left ventricular systolic function. A total of 174 patients presenting with acute anterior STEMI and treated with primary percutaneous coronary intervention were included and divided into subgroups of admission platelet blood count of <200 K, 200-300 K, 300-400 K and >400 K. Evaluation of coronary artery flow and myocardial blush grade was performed according to the TIMI criteria. Electrocardiographic ST elevation resolution post-primary percutaneous coronary intervention was evaluated. Doppler echocardiographic evaluation of left anterior descending coronary artery velocities early and late after primary percutaneous coronary intervention and assessment of left ventricular ejection fraction and wall motion score index (WMSI) of left ventricular and left anterior descending coronary artery territory were performed. Post-primary percutaneous coronary intervention TIMI, myocardial blush grade and ST elevation resolution were similar in all groups. Patients with platelet counts <200 K had higher peak diastolic left anterior descending coronary artery velocity both early and late after primary percutaneous coronary intervention, and higher prevalence of left anterior descending coronary artery velocity deceleration time exceeding 600 ms, (45.5% vs. 40%, P<0.05). Patients with platelet counts >400 K presented with worse left ventricular ejection fraction, left ventricular WMSI and left anterior descending coronary artery WMSI, and before discharge this subgroup had worse left ventricular WMSI and left anterior descending coronary artery WMSI, P<0.01. Patients with anterior STEMI treated by primary percutaneous coronary intervention with lower admission platelet count had higher left anterior descending coronary artery diastolic velocities, better myocardial perfusion with more patients having left anterior descending coronary artery-descending coronary artery velocity deceleration time >600 ms. Patients with higher platelet counts had lower left ventricular systolic function both at admission and before discharge.
Ma, Jianying; Qian, Juying; Zeng, Xin; Sun, Aijun; Chang, Shufu; Chen, Zhangwei; Zou, Yunzeng
2012-01-01
Introduction Although coronary microembolization (CME) is a frequent phenomenon in patients undergoing percutaneous coronary intervention, few data are available on the changes in left ventricular ejection fraction (LVEF) and coronary flow reserve (CFR) after CME. Material and methods In this study, six miniature swine of either sex (body weight 21-25 kg) were used to prepare a CME model. After coronary angiography, 1.2 × 105 microspheres (42 µm) were selectively infused into the left anterior descending artery via an infusion catheter. Left ventricular ejection fraction was evaluated using transthoracic echocardiography; myocardial blood flow was measured using coloured microspheres; and CFR and coronary pressure were measured using Doppler and a pressure wire. Results Left ventricular ejection fraction was 0.77 ±0.08 at baseline, 0.69 ±0.08 at 2 h, 0.68 ±0.08 at 6 h, and 0.76 ±0.06 at 1 week (2 h vs. baseline p < 0.05; 6 h vs. baseline p < 0.01). After CME, left ventricular end systolic volume (LVESV) and end diastolic volume (LVEDV) were significant larger 1 week later (p < 0.01 for both), while CFR was significantly reduced at 6 h (1.24 ±0.10 at 6 h vs. 1.77 ±0.30 at baseline, p < 0.01) and myocardial blood flow remained unchanged. Serum ET-1 level was significantly higher only at 6 h after CME (6 h vs. baseline p < 0.05). Conclusions Reduction of CFR and LVEF is significant at 6 h after CME and recovers 1 week later with left ventricular dilation. PMID:22457677
Dynamical relations for left ventricular ejection - Flow rate, momentum, force and impulse
NASA Technical Reports Server (NTRS)
Back, L. H.; Selzer, R. H.; Gordon, D. G.; Ledbetter, D. C.; Crawford, D. W.
1984-01-01
An investigation was carried out to quantitatively evaluate left ventricular volume flow rate, momentum, force and impulse derived from application of conservation principles for mass and momentum of blood within the ventricle during the ejection phase. An automated digital image processing system was developed and applied to left ventricular angiograms which are computer processed and analyzed frame by frame to determine the dynamical relations by numerical methods. The initial experience with force and impulse has indicated that neither quantity seemed to be a sensitive indicator of coronary artery disease as evaluated by qualitative angiography for the particular patient group studied. Utilization of the dynamical relations in evaluating human left ventricular performance requires improved means of measurement and interpretation of clinical studies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Borovetz, H.S.; Shaffer, F.; Schaub, R.
This paper discusses a series of experiments to visualize and measure flow fields in the Novacor left ventricular assist system (LVAS). The experiments utilize a multiple exposure, optical imaging technique called fluorescent image tracking velocimetry (FITV) to hack the motion of small, neutrally-buoyant particles in a flowing fluid.
Response of the Cardiovascular System to Vibration and Combined Stresses
1975-08-31
Canines were chronically instrumented for continuous measurements of ascending aortic flow ( Zepeda ), left ventricular pressure (Konigsberg), circum- flex...different animals. Each dog was chronically instrumented for continuous measuremernt of ascending aortic flow ( Zepeda ), left ventricular pressure...vibration protocol as those animals restrained vertically. METHODS Canines (16 to 22 kg) were chronically instrumented with electromagnetic flow cuffs ( Zepeda
In vivo quantification of intraventricular flow during left ventricular assist device support
NASA Astrophysics Data System (ADS)
Vu, Vi; Wong, Kin; Del Alamo, Juan; Aguilo, Pablo M. L.; May-Newman, Karen; Department of Bioengineering, San Diego State University Collaboration; Department of Mechanical; Aerospace Engineering, University of California San Diego Collaboration; Mechanical Assist Device Program, Sharp Memorial Hospital Collaboration
2014-11-01
Left ventricular assist devices (LVADs) are mechanical pumps that are surgically connected to the left ventricle (LV) and aorta to increase aortic flow and end-organ perfusion. Clinical studies have demonstrated that LVADs improve patient health and quality of life and significantly reduce the mortality of cardiac failure. However, In the presence of left ventricular assisted devices (LVAD), abnormal flow patterns and stagnation regions are often linked to thrombosis. The aim of our study is to evaluate the flow patterns in the left ventricle of the LVAD-assisted heart, with a focus on alterations in vortex development and blood stasis. To this aim, we applied color Doppler echocardiography to measure 2D, time resolved velocity fields in patients before and after implantation of LVADs. In agreement with our previous in vitro studies (Wong et al., Journal of Biomechanics 47, 2014), LVAD implantation resulted in decreased flow velocities and increased blood residence time near the outflow tract. The variation of residence time changes with LVAD operational speed was characterized for each patient.
Right Ventricular Perfusion: Physiology and Clinical Implications.
Crystal, George J; Pagel, Paul S
2018-01-01
Regulation of blood flow to the right ventricle differs significantly from that to the left ventricle. The right ventricle develops a lower systolic pressure than the left ventricle, resulting in reduced extravascular compressive forces and myocardial oxygen demand. Right ventricular perfusion has eight major characteristics that distinguish it from left ventricular perfusion: (1) appreciable perfusion throughout the entire cardiac cycle; (2) reduced myocardial oxygen uptake, blood flow, and oxygen extraction; (3) an oxygen extraction reserve that can be recruited to at least partially offset a reduction in coronary blood flow; (4) less effective pressure-flow autoregulation; (5) the ability to downregulate its metabolic demand during coronary hypoperfusion and thereby maintain contractile function and energy stores; (6) a transmurally uniform reduction in myocardial perfusion in the presence of a hemodynamically significant epicardial coronary stenosis; (7) extensive collateral connections from the left coronary circulation; and (8) possible retrograde perfusion from the right ventricular cavity through the Thebesian veins. These differences promote the maintenance of right ventricular oxygen supply-demand balance and provide relative resistance to ischemia-induced contractile dysfunction and infarction, but they may be compromised during acute or chronic increases in right ventricle afterload resulting from pulmonary arterial hypertension. Contractile function of the thin-walled right ventricle is exquisitely sensitive to afterload. Acute increases in pulmonary arterial pressure reduce right ventricular stroke volume and, if sufficiently large and prolonged, result in right ventricular failure. Right ventricular ischemia plays a prominent role in these effects. The risk of right ventricular ischemia is also heightened during chronic elevations in right ventricular afterload because microvascular growth fails to match myocyte hypertrophy and because microvascular dysfunction is present. The right coronary circulation is more sensitive than the left to α-adrenergic-mediated constriction, which may contribute to its greater propensity for coronary vasospasm. This characteristic of the right coronary circulation may increase its vulnerability to coronary vasoconstriction and impaired right ventricular perfusion during administration of α-adrenergic receptor agonists.
Zhang, Chuan; Zha, Dao-Gang; DU, Rong-Sheng; Hu, Feng; Li, Sheng-Hui; Wu, Xiao-Yuan; Liu, Yi-Li
2009-07-01
To assess the value of velocity vector imaging (VVI) and quantitative tissue velocity imaging (QTVI) in assessing left ventricular diastolic function of the dogs with acute myocardial ischemia. Six healthy mongrel dogs were subjected to ligation of the left circumflex artery or left anterior descending artery to induce coronary artery stenosis of varying degrees. The mean peak diastolic velocity (Em) of the ventricular walls around the mitral annulus was recorded with VVI or QTVI in the coronary blood flow. The left ventricular end diastolic pressure (LVEDP) was measured with pigtail catheter in the left ventricle. As the coronary blood flow decreased, LVEDP was gradually increased, and Em measured by VVI or QTVI were also gradually decreased. A good linear correlation was shown between Em measured by VVI or QTVI and LVEDP (r=-0.834, P<0.001, and r=-0.68, P<0.001, respectively). A significant difference was observed in the correlation coefficient between VVI and QTVI (Z=2.625, P=0.0087). VVI and QTVI both provide good noninvasive means for measuring left ventricular diastolic function. VVI, a new echocardiographic modality without angular dependence, is better than QTVI in evaluating left ventricular diastolic function.
Biventricular support with the Jarvik 2000 axial flow pump: a feasibility study.
Radovancevic, Branislav; Gregoric, Igor D; Tamez, Daniel; Vrtovec, Bojan; Tuzun, Egemen; Chee, Hyun Keun; Moore, Sheila; Jarvik, Robert K; Frazier, O H
2003-01-01
Patients with congestive heart failure who are supported with a left ventricular assist device (LVAD) may experience right ventricular dysfunction or failure that requires support with a right ventricular assist device (RVAD). To determine the feasibility of using a clinically available axial flow ventricular assist device as an RVAD, we implanted Jarvik 2000 pumps in the left ventricle and right atrium of two Corriente crossbred calves (approximately 100 kg each) by way of a left thoracotomy and then analyzed the hemodynamic effects in the mechanically fibrillated heart at various LVAD and RVAD speeds. Right atrial implantation of the device required no modification of either the device or the surgical technique used for left ventricular implantation. Satisfactory biventricular support was achieved during fibrillation as evidenced by an increase in mean aortic pressure from 34 mm Hg with the pumps off to 78 mm Hg with the pumps generating a flow rate of 4.8 L/min. These results indicate that the Jarvik 2000 pump, which can provide chronic circulatory support and can be powered by external batteries, is a feasible option for right ventricular support after LVAD implantation and is capable of completely supporting the circulation in patients with global heart failure.
Implantable physiologic controller for left ventricular assist devices with telemetry capability.
Asgari, Siavash S; Bonde, Pramod
2014-01-01
Rotary type left ventricular assist devices have mitigated the problem of durability associated with earlier pulsatile pumps and demonstrated improved survival. However, the compromise is the loss of pulsatility due to continuous flow and retained percutaneous driveline leading to increased mortality and morbidity. Lack of pulsatility is implicated in increased gastrointestinal bleeding, aortic incompetence, and diastolic hypertension. We present a novel, wirelessly powered, ultra-compact, implantable physiologic controller capable of running a left ventricular assist device in a pulsatile mode with wireless power delivery. The schematic of our system was laid out on a circuit board to wirelessly receive power and run a left ventricular assist device with required safety and backup measures. We have embedded an antenna and wireless network for telemetry. Multiple signal processing steps and controlling algorithm were incorporated. The controller was tested in in vitro and in vivo experiments. The controller drove left ventricular assist devices continuously for 2 weeks in an in vitro setup and in vivo without any failure. Our controller is more power efficient than the current Food and Drug Administration-approved left ventricular assist device controllers. When used with electrocardiography synchronization, the controller allowed on-demand customization of operation with instantaneous flow and revolutions per minute changes, resulting in a pulsatile flow with adjustable pulse pressure. Our test results prove the system to be remarkably safe, accurate, and efficient. The unique combination of wireless powering and small footprint makes this system an ideal totally implantable physiologic left ventricular assist device system. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Kingma, J G; Linderoth, B; Ardell, J L; Armour, J A; DeJongste, M J; Foreman, R D
2001-08-13
Electrical stimulation of the dorsal aspect of the upper thoracic spinal cord is used increasingly to treat patients with angina pectoris refractory to conventional therapeutic strategies. The purpose of this study was to determine whether spinal cord stimulation (SCS) in dogs affects regional myocardial blood flow and left-ventricular (LV) function before and during transient obstruction of the left anterior descending coronary artery (LAD). In anesthetized dogs, regional myocardial blood flow distribution was determined using radiolabeled microspheres and left-ventricular function was measured by impedance-derived pressure-volume loops. SCS was accomplished by stimulating the dorsal T1-T2 segments of the spinal cord using epidural bipolar electrodes at 90% of motor threshold (MT) (50 Hz, 0.2-ms duration). Effects of 5-min SCS were assessed under basal conditions and during 4-min occlusion of the LAD. SCS alone evoked no change in regional myocardial blood flow or cardiovascular indices. Transient LAD occlusion significantly diminished blood flow within ischemic, but not in non-ischemic myocardial tissue. Left ventricular pressure-volume loops were shifted rightward during LAD occlusion. Cardiac indices were altered similarly during LAD occlusion and concurrent SCS. SCS does not influence the distribution of blood flow within the non-ischemic or ischemic myocardium. Nor does it modify LV pressure-volume dynamics in the anesthetized experimental preparation.
Is Doppler tissue velocity during early left ventricular filling preload independent?
NASA Technical Reports Server (NTRS)
Yalcin, F.; Kaftan, A.; Muderrisoglu, H.; Korkmaz, M. E.; Flachskampf, F.; Garcia, M.; Thomas, J. D.
2002-01-01
BACKGROUND: Transmitral Doppler flow indices are used to evaluate diastolic function. Recently, velocities measured by Doppler tissue imaging have been used as an index of left ventricular relaxation. OBJECTIVE: To determine whether Doppler tissue velocities are influenced by alterations in preload. METHODS: Left ventricular preload was altered in 17 patients (all men, mean (SD) age, 49 (8) years) during echocardiographic measurements of left ventricular end diastolic volume, maximum left atrial area, peak early Doppler filling velocity, and left ventricular myocardial velocities during early filling. Preload altering manoeuvres included Trendelenberg (stage 1), reverse Trendelenberg (stage 2), and amyl nitrate (stage 3). Systolic blood pressure was measured at each stage. RESULTS: In comparison with baseline, left ventricular end diastolic volume (p = 0.001), left atrial area (p = 0.003), peak early mitral Doppler filling velocity (p = 0.01), and systolic blood pressures (p = 0.001) were all changed by preload altering manoeuvres. Only left ventricular myocardial velocity during early filling remained unchanged by these manoeuvres. CONCLUSIONS: In contrast to standard transmitral Doppler filling indices, Doppler tissue early diastolic velocities are not significantly affected by physiological manoeuvres that alter preload. Thus Doppler tissue velocities during early left ventricular diastole may provide a better index of diastolic function in cardiac patients by providing a preload independent assessment of left ventricular filling.
Device Management and Flow Optimization on Left Ventricular Assist Device Support.
Tchoukina, Inna; Smallfield, Melissa C; Shah, Keyur B
2018-07-01
The authors discuss principles of continuous flow left ventricular assist device (LVAD) operation, basic differences between the axial and centrifugal flow designs and hemodynamic performance, normal LVAD physiology, and device interaction with the heart. Systematic interpretation of LVAD parameters and recognition of abnormal patterns of flow and pulsatility on the device interrogation are necessary for clinical assessment of the patient. Optimization of pump flow using LVAD parameters and echocardiographic and hemodynamics guidance are reviewed. Copyright © 2018 Elsevier Inc. All rights reserved.
Lee, Ga Yeon; Park, Sung-Ji; Kim, Sujin; Choi, Namgyung; Jeong, Dong Seop; Jeon, Eun-Seok; Lee, Young Tak
2014-01-01
Left ventricular assist device (LVAD) is a good treatment option for the patients ineligible for cardiac transplantation. Several studies have demonstrated that a ventricular assist device improves the quality of life and prognosis of the patients with end-stage heart failure. A 75-yr-old man debilitated with New York Heart Association (NYHA) functional class III-IV due to severe left ventricular systolic dysfunction received LVAD implantation as a destination therapy. The patient was discharged with improved functional status (NYHA functional class II) after appropriate cardiac rehabilitation and education about how to manage the device and potential emergency situations. This is the first case of successful continuous-flow LVAD implantation as a destination therapy in Korea.
Cornwell, William K; Tarumi, Takashi; Stickford, Abigail; Lawley, Justin; Roberts, Monique; Parker, Rosemary; Fitzsimmons, Catherine; Kibe, Julius; Ayers, Colby; Markham, David; Drazner, Mark H; Fu, Qi; Levine, Benjamin D
2015-12-15
Current-generation left ventricular assist devices provide circulatory support that is minimally or entirely nonpulsatile and are associated with marked increases in muscle sympathetic nerve activity (MSNA), likely through a baroreceptor-mediated pathway. We sought to determine whether the restoration of pulsatile flow through modulations in pump speed would reduce MSNA through the arterial baroreceptor reflex. Ten men and 3 women (54 ± 14 years) with Heartmate II continuous-flow left ventricular assist devices underwent hemodynamic and sympathetic neural assessment. Beat-to-beat blood pressure, carotid ultrasonography at the level of the arterial baroreceptors, and MSNA via microneurography were continuously recorded to determine steady-state responses to step changes (200-400 revolutions per minute) in continuous-flow left ventricular assist device pump speed from a maximum of 10,480 ± 315 revolutions per minute to a minimum of 8500 ± 380 revolutions per minute. Reductions in pump speed led to increases in pulse pressure (high versus low speed: 17 ± 7 versus 26 ± 12 mm Hg; P<0.01), distension of the carotid artery, and carotid arterial wall tension (P<0.05 for all measures). In addition, MSNA was reduced (high versus low speed: 41 ± 15 versus 33 ± 16 bursts per minute; P<0.01) despite a reduction in mean arterial pressure and was inversely related to pulse pressure (P=0.037). Among subjects with continuous-flow left ventricular assist devices, the restoration of pulsatile flow through modulations in pump speed leads to increased distortion of the arterial baroreceptors with a subsequent decline in MSNA. Additional study is needed to determine whether reduction of MSNA in this setting leads to improved outcomes. © 2015 American Heart Association, Inc.
Djordjevic Dikic, Ana; Nikcevic, Gabrijela; Raspopovic, Srdjan; Jovanovic, Velibor; Tesic, Milorad; Beleslin, Branko; Stepanovic, Jelena; Giga, Vojislav; Milasinovic, Goran
2014-12-01
The aim of the study was to assess the value of coronary flow reserve (CFR) for predicting improvement of left ventricular function after cardiac resynchronization therapy (CRT). Study population included 40 patients (mean age 58 ± 9 years) with heart failure (ejection fraction 25, 7 ± 5, 4%) and QRS duration of 158 ± 22 ms, planned for CRT. Before and after CRT implantation, CFR was measured non-invasively during hyperaemia induced with adenosine. Responders were defined by decrease in end-systolic volume ≥15%. Follow-up echocardiography and CFR measurements were obtained after 6 months. At baseline there was no significant difference in left ventricular ejection fraction (LVEF), QRS duration, 6 min walk test distance and coronary flow velocity at rest between responder (n = 26) vs. non-responder group (n = 14, P = ns). Before CRT implantation, responders compared with non-responders, showed a greater increase in coronary flow velocity during hyperaemia, and consequently higher CFR: 2.41 ± 0.60 vs. 1.61 ± 0.45 (P = 0.001). There was significant correlation between CFR before CRT implantation and LVEF after 6 months (r = 0.545, P = 0.001). End-diastolic, end-systolic left ventricular diameter, and CFR before CRT were predictors of LV functional improvement. By multivariate analysis, only CFR before CRT was independent predictor of left ventricular recovery in the follow-up period (P = 0.001). Our results demonstrate that preserved CFR in patients with dilated cardiomyopathy is predictive of left ventricular improvement after CRT implantation. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.
Malakan Rad, Elaheh; Awad, Sawsan; Hijazi, Ziyad M
2014-01-01
Congenital left ventricular outpouchings (LVOs) are reported under five overlapping and poorly defined terms including left ventricular accessory chamber, left ventricular aneurysm (LVA), left ventricular diverticulum (LVD), double-chambered LV, and accessory left ventricle. Diagnostic criteria are frequently mixed and not mutually exclusive. They convey no information regarding treatment strategy and prognosis. The aim of this systematic review is to provide a clear and inclusive classification, with therapeutic and prognostic implications, for congenital LVOs. We performed three separate sets of search on three subjects including "congenital left ventricular outpouchings," "important and simply measurable markers of left ventricular function," and "relationship of mechanics of intraventricular blood flow and optimal vortex formation in left ventricle and elliptical geometry of LV." We enrolled case series, review articles, and case reports with literature review. All types of acquired LVO's were excluded. We studied the abstracts of all searched articles. We focused on diagnostic criteria and patients' outcome. To examine the validity and reliability of the novel classification, fifteen previous studies were revisited using the novel classification. A total of 20 papers from 11 countries fulfilled our inclusion criteria. The age of patients ranged from prenatal age to geriatric age range. Diagnostic criteria were clearly stated only for two of the above five terms (i.e., congenital LVA and congenital LVD). Cases with mixed diagnostic criteria were frequent.Elliptical geometry of left ventricle was found to have significant impact on effective blood flow mechanics in LV. A simple inclusive classification for congenital LVOs, with therapeutic and prognostic implications, was introduced. The cornerstone of this classification is elliptical LV geometry. Large-type IIc LVO have dismal prognosis, if left untreated. LVO type I and small LVO type IIa have the best prognosis. © 2014 Wiley Periodicals, Inc.
Gupta, Vikas; Bustamante, Mariana; Fredriksson, Alexandru; Carlhäll, Carl-Johan; Ebbers, Tino
2018-01-01
Assessment of blood flow in the left ventricle using four-dimensional flow MRI requires accurate left ventricle segmentation that is often hampered by the low contrast between blood and the myocardium. The purpose of this work is to improve left-ventricular segmentation in four-dimensional flow MRI for reliable blood flow analysis. The left ventricle segmentations are first obtained using morphological cine-MRI with better in-plane resolution and contrast, and then aligned to four-dimensional flow MRI data. This alignment is, however, not trivial due to inter-slice misalignment errors caused by patient motion and respiratory drift during breath-hold based cine-MRI acquisition. A robust image registration based framework is proposed to mitigate such errors automatically. Data from 20 subjects, including healthy volunteers and patients, was used to evaluate its geometric accuracy and impact on blood flow analysis. High spatial correspondence was observed between manually and automatically aligned segmentations, and the improvements in alignment compared to uncorrected segmentations were significant (P < 0.01). Blood flow analysis from manual and automatically corrected segmentations did not differ significantly (P > 0.05). Our results demonstrate the efficacy of the proposed approach in improving left-ventricular segmentation in four-dimensional flow MRI, and its potential for reliable blood flow analysis. Magn Reson Med 79:554-560, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.
Intraatrial baffle repair of isolated ventricular inversion with left atrial isomerism.
McElhinney, D B; Reddy, V M; Silverman, N H; Hanley, F L
1996-11-01
Isolated ventricular inversion with left atrial isomerism, partial anomalous pulmonary venous connection, and interruption of the inferior vena cava with azygos continuation to a right superior vena cava was diagnosed by echocardiography in a neonate. At 48 days of age, the patient underwent successful anatomic correction with redirection of flow from the superior vena cava and hepatic veins to the left-sided tricuspid valve, and flow from the pulmonary veins to the right-sided mitral valve. In the present report, the surgical techniques of this case are described, along with a survey of the surgical literature covering anatomic repair of isolated ventricular inversion.
Mechanism of reduction of mitral regurgitation with vasodilator therapy.
Yoran, C; Yellin, E L; Becker, R M; Gabbay, S; Frater, R W; Sonnenblick, E H
1979-04-01
Acute mitral regurgitation was produced in six open chest dogs by excising a portion of the anterior valve leaflet. Electromagnetic flow probes were placed in the left atrium around the mitral anulus and in the ascending aorta to determine phasic left ventricular filling volume, regurgitant volume and stroke volume. The systolic pressure gradient was calculated from simultaneously measured high fidelity left atrial and left ventricular pressures. The effective mitral regurgitant orifice area was calculated from Gorlin's hydraulic equation. Infusion of nitroprusside resulted in a significant reduction in mitral regurgitation. No significant change occurred in the systolic pressure gradient between the left ventricle and the left atrium because both peak left ventricular pressure and left atrial pressure were reduced. The reduction of mitral regurgitation was largely due to reduction in the size of the mitral regurgitant orifice. Reduction of ventricular volume rather than the traditional concept of reduction of impedance of left ventricular ejection may explain the effects of vasodilators in reducing mitral regurgitation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brown, C.G.; Werman, H.A.; Davis, E.A.
1987-02-01
Although epinephrine has been shown to improve myocardial blood flow during cardiopulmonary resuscitation (CPR), the effects of standard as well as larger doses of epinephrine on regional myocardial blood flow have not been examined. In this study we compared the effects of various doses of epinephrine on regional myocardial blood flow after a 10 min arrest in a swine preparation. Fifteen swine weighing greater than 15 kg each were instrumented for regional myocardial blood flow measurements with tracer microspheres. Regional blood flow was measured during normal sinus rhythm. After 10 min of ventricular fibrillation, CPR was begun and regional myocardialmore » blood flow was determined. Animals were then randomly assigned to receive 0.02, 0.2, or 2.0 mg/kg epinephrine by peripheral injection. One minute after drug administration, regional myocardial blood flow measurements were repeated. The adjusted regional myocardial blood flows (ml/min/100 g) for animals given 0.02, 0.2, and 2.0 mg/kg epinephrine, respectively, were as follows: left atrium, 0.9, 67.4, and 58.8; right atrium, 0.3, 46.2, and 38.5; right ventricle, 0.7, 82.3, and 66.9; right interventricular septum, 1.7, 125.5, and 99.1; left interventricular septum, 2.8, 182.8, 109.5; mesointerventricular septum, 16.8, 142.2, and 79.2; left ventricular epicardium, 19.2, 98.5 and 108.7; left ventricular mesocardium, 22.8, 135.0, and 115.8; and left ventricular endocardium, 2.5, 176.1, and 132.9). All comparisons between the groups receiving 0.02 and 0.2 mg/kg epinephrine were statistically significant (p less than .05).« less
Effect of diastolic flow patterns on the function of the left ventricle
NASA Astrophysics Data System (ADS)
Seo, Jung Hee; Mittal, Rajat
2013-11-01
Direct numerical simulations are used to study the effect of intraventricular flow patterns on the pumping efficiency and the blood mixing and transport characteristics of the left ventricle. The simulations employ a geometric model of the left ventricle which is derived from contrast computed tomography. A variety of diastolic flow conditions are generated for a fixed ejection fraction in order to delineate the effect of flow patterns on ventricular performance. The simulations indicate that the effect of intraventricular blood flow pattern on the pumping power is physiologically insignificant. However, diastolic flow patterns have a noticeable effect on the blood mixing as well as the residence time of blood cells in the ventricle. The implications of these findings on ventricular function are discussed.
Fluid dynamics model of mitral valve flow: description with in vitro validation.
Thomas, J D; Weyman, A E
1989-01-01
A lumped variable fluid dynamics model of mitral valve blood flow is described that is applicable to both Doppler echocardiography and invasive hemodynamic measurement. Given left atrial and ventricular compliance, initial pressures and mitral valve impedance, the model predicts the time course of mitral flow and atrial and ventricular pressure. The predictions of this mathematic formulation have been tested in an in vitro analog of the left heart in which mitral valve area and atrial and ventricular compliance can be accurately controlled. For the situation of constant chamber compliance, transmitral gradient is predicted to decay as a parabolic curve, and this has been confirmed in the in vitro model with r greater than 0.99 in all cases for a range of orifice area from 0.3 to 3.0 cm2, initial pressure gradient from 2.4 to 14.2 mm Hg and net chamber compliance from 16 to 29 cc/mm Hg. This mathematic formulation of transmitral flow should help to unify the Doppler echocardiographic and catheterization assessment of mitral stenosis and left ventricular diastolic dysfunction.
Kaku, T; Sakurai, S; Furuno, Y; Yashiro, A; Nakashima, Y; Kuroiwa, A
1995-08-01
We evaluated the effects of systolic anterior motion systolic anterior motion of the mitral valve on cardiac haemodynamics. Seven adult mongrel dogs in which systolic anterior motion-septal contact was observed after dobutamine administration were used. To exclude the effects of left ventricular function and morphology, a stone removal basket catheter was placed in the left ventricular outflow tract, and haemodynamics were compared with the basket closed and opened. The basket was opened five times in three dogs not showing systolic anterior motion-septal contact, but the basket itself did not effect the haemodynamics. In the seven dogs that showed systolic anterior motion-septal contact without left ventricular hypertrophy, the basket was opened a total of 33 times in the presence of various degrees of systolic anterior motion-septal contact. After opening the basket, systolic anterior motion was reduced echocardiographically, and significant (P<0.01) changes were observed in the left ventricle-aorta pressure gradient (from 68 +/- 22 to 25 +/- 15 mm Hg), the systolic ejection period (from 146 +/- 19 to 135 +/- 16 ms), and the stroke volume (SV; from 9.4 +/- 2.9 to 10.1 +/- 3.3 ml). After basket inflation, aortic pressure and aortic flow waveforms changed but the peak pressure and flow velocity did not. The temporal distribution of left ventricular ejection also definitely changed after the basket was opened. No changes were observed in the peak dp/dt, peak negative dp/dt, time constant, left ventricular end-diastolic pressure, or left atrial pressure. These observations in this animal model of systolic anterior motion without left ventricular hypertrophy suggest that: (1) there is no potential for generation of an intra-cavity gradient in the absence of systolic anterior motion of the mitral valve, so that (2) systolic anterior motion narrowed the left ventricular outflow tract and, consequently, produced the systolic ejection period, and affected the left ventricular ejection dynamics, and that (3) the basket catheter is useful because it allows these assessments in the same heart with a nearly fixed left ventricular contractility, at least in our animal model.
Dekker, André L A J; Reesink, Koen D; van der Veen, Frederik H; van Ommen, G Vincent A; Geskes, Gijs G; Soemers, A Cecilia M; Maessen, Jos G
2003-04-01
Acute mitral regurgitation (MR) is present in 10% of patients presenting with cardiogenic shock. To stabilize these patients, intra-aortic balloon pumping (IABP) is recommended, but the mechanism of IABP support in these patients is unknown. This animal study was designed to describe the hemodynamic effect of intra-aortic balloon pumping during cardiogenic shock induced by acute MR. In eight calves, left ventricular pressure-volume loops, aortic and left atrial pressure, and aortic, carotid artery, and coronary blood flow were recorded. Acute MR (range 36%-79%) was created by placing a metal cage in the mitral valve. Hemodynamic data was obtained at control, during acute MR, and during acute MR with 1:1 IABP support. Acute MR caused a decrease in cardiac output (-32%, P = 0.018), blood pressure, and carotid artery flow, whereas left ventricular output (+127%, P = 0.018), end-diastolic volume, and left atrial pressure all significantly increased. Stroke work, ejection fraction, and coronary blood flow were not significantly changed, and no signs of ischemia were seen on the ECG. The IABP raised average cardiac output by 31% (P = 0.012) and significantly raised blood pressure and flow to the brain while decreasing systemic vascular resistance. Left ventricular function and mean coronary blood flow did not change, but diastolic coronary flow became more important as shown by the increase in diastolic fraction from 64% to 95%. (P = 0.028). Average MR dropped by 7.5% (P = 0.025). In conclusion, application of the IABP during acute MR lowers aortic impedance, resulting in less MR and more output toward the aorta without changing left ventricular function.
NASA Astrophysics Data System (ADS)
Larsson, David; Spühler, Jeannette H.; Günyeli, Elif; Weinkauf, Tino; Hoffman, Johan; Colarieti-Tosti, Massimiliano; Winter, Reidar; Larsson, Matilda
2017-03-01
Echocardiography is the most commonly used image modality in cardiology, assessing several aspects of cardiac viability. The importance of cardiac hemodynamics and 4D blood flow motion has recently been highlighted, however such assessment is still difficult using routine echo-imaging. Instead, combining imaging with computational fluid dynamics (CFD)-simulations has proven valuable, but only a few models have been applied clinically. In the following, patient-specific CFD-simulations from transthoracic dobutamin stress echocardiography have been used to analyze the left ventricular 4D blood flow in three subjects: two with normal and one with reduced left ventricular function. At each stress level, 4D-images were acquired using a GE Vivid E9 (4VD, 1.7MHz/3.3MHz) and velocity fields simulated using a presented pathway involving endocardial segmentation, valve position identification, and solution of the incompressible Navier-Stokes equation. Flow components defined as direct flow, delayed ejection flow, retained inflow, and residual volume were calculated by particle tracing using 4th-order Runge-Kutta integration. Additionally, systolic and diastolic average velocity fields were generated. Results indicated no major changes in average velocity fields for any of the subjects. For the two subjects with normal left ventricular function, increased direct flow, decreased delayed ejection flow, constant retained inflow, and a considerable drop in residual volume was seen at increasing stress. Contrary, for the subject with reduced left ventricular function, the delayed ejection flow increased whilst the retained inflow decreased at increasing stress levels. This feasibility study represents one of the first clinical applications of an echo-based patient-specific CFD-model at elevated stress levels, and highlights the potential of using echo-based models to capture highly transient flow events, as well as the ability of using simulation tools to study clinically complex phenomena. With larger patient studies planned for the future, and with the possibility of adding more anatomical features into the model framework, the current work demonstrates the potential of patient-specific CFD-models as a tool for quantifying 4D blood flow in the heart.
NASA Technical Reports Server (NTRS)
Erickson, H. H.; Stone, H. L.
1972-01-01
The mechanisms by which acute hypoxia (10% and 5% oxygen) mediates changes in coronary blood flow and cardiac function were investigated in the conscious dog. When the dogs breathed hypoxic gas mixtures through a tracheostomy, both arterial and coronary sinus oxygen tensions were significantly decreased. With 5% oxygen, there were significant increases in heart rate (25%), maximum left ventricular dP/dt (39%), left circumflex coronary artery blood flow (163%), and left ventricular oxygen consumption (52%), which were attenuated by beta-adrenergic blockage with propranolol. When electrical pacing was used to keep the ventricular rate constant during hypoxia, there was no significant difference in coronary blood flow before and after beta blockade. Beta-adrenergic receptor activity in the myocardium participates in the integrated response to hypoxia although it may not cause active vasodilation of the coronary vessels.
NASA Astrophysics Data System (ADS)
Tan, Sean Guo-Dong; Kim, Sangho; Leo, Hwa Liang
2016-06-01
Mechanical heart valve prostheses are often implanted in young patients due to their durability and long-term reliability. However, existing designs are known to induce elevated levels of blood damage and blood platelet activation. As a result, there is a need for patients to undergo chronic anti-coagulation treatment to prevent thrombosis, often resulting in bleeding complications. Furthermore, recent studies have suggested that the implantation of a mechanical prosthetic valve at the mitral position results in a significant alteration of the left ventricular flow field which may contribute to flow turbulence. This study proposes a bi-leaflet mechanical heart valve design (Bio-MHV) that mimics the geometry of a human mitral valve, with the aim of reducing turbulence levels in the left ventricle by replicating physiological flow patterns. An in vitro three-dimensional particle velocimetry imaging experiment was carried out to compare the hemodynamic performance of the Bio-MHV with that of the clinically established ATS valve. The Bio-MHV was found to replicate physiological left ventricular flow patterns and produced lower turbulence levels.
Radulescu, D; Buzdugan, E; Ciuleanu, T E; Todor, N; Stoicescu, L
2013-01-01
The aim of this study was to assess whether treatment with angiotensin converting enzyme inhibitors (ACEI) can prevent the alteration of left ventricular systolic and diastolic performance in cancer patients treated with different chemotherapy regimens containing epirubicin. In this prospective study , 68 patients with different malignant tumors treated with epirubicin and perindopril in different chemotherapy protocols (study group), and a gender- and age-matched group of 68 patients with different malignant tumors treated with epirubicin without perindopril in different chemotherapy protocols (control group), were assessed by Doppler echocardiography. Left ventricular systolic function was assessed by measuring left ventricular ejection fraction (EF). Left ventricular diastolic function was assessed by Doppler ultrasound by evaluating the transmitral flow. We also assessed the QTc on the 12 lead electrocardiograms. At the end of chemotherapy the left ventricular systolic function was less altered in the study group compared to the control group and was superior in the study group (epirubicin+ACEI) compared to the control group (epirubicin alone). We documented a significantly deteriorated left ventricular diastolic function in both groups at the completion of chemotherapy. QTc time in both arms was also significantly prolonged. In the present echo-Doppler study we documented a preserved left ventricular systolic performance in patients with various malignancies treated with epirubicin plus perindopril. Although co-treatment with ACEI prevented the alteration of systolic performance, it failed to prevent the deterioration of the left ventricular diastolic performance impairment due to poor left ventricular compliance.
Experimental Assessment of the Hydraulics of a Miniature Axial-Flow Left Ventricular Assist Device
NASA Astrophysics Data System (ADS)
Smith, P. Alex; Cohn, William; Metcalfe, Ralph
2017-11-01
A minimally invasive partial-support left ventricular assist device (LVAD) has been proposed with a flow path from the left atrium to the arterial system to reduce left ventricular stroke work. In LVAD design, peak and average efficiency must be balanced over the operating range to reduce blood trauma. Axial flow pumps have many geometric parameters. Until recently, testing all these parameters was impractical, but modern 3D printing technology enables multi-parameter studies. Following theoretical design, experimental hydraulic evaluation in steady state conditions examines pressure, flow, pressure-flow gradient, efficiency, torque, and axial force as output parameters. Preliminary results suggest that impeller blades and stator vanes with higher inlet angles than recommended by mean line theory (MLT) produce flatter gradients and broader efficiency curves, increasing compatibility with heart physiology. These blades also produce less axial force, which reduces bearing load. However, they require slightly higher torque, which is more demanding of the motor. MLT is a low order, empirical model developed on large pumps. It does not account for the significant viscous losses in small pumps like LVADs. This emphasizes the importance of experimental testing for hydraulic design. Roderick D MacDonald Research Fund.
Berg, Robert A; Sorrell, Vincent L; Kern, Karl B; Hilwig, Ronald W; Altbach, Maria I; Hayes, Melinda M; Bates, Kathryn A; Ewy, Gordon A
2005-03-08
Most out-of-hospital ventricular fibrillation (VF) is prolonged (>5 minutes), and defibrillation from prolonged VF typically results in asystole or pulseless electrical activity. Recent visual epicardial observations in an open-chest, open-pericardium model of swine VF indicate that blood flows from the high-pressure arterial system to the lower-pressure venous system during untreated VF, thereby overdistending the right ventricle and apparently decreasing left ventricular size. Therefore, inadequate left ventricular stroke volume after defibrillation from prolonged VF has been postulated as a major contributor to the development of pulseless rhythms. Ventricular dimensions were determined by MRI for 30 minutes of untreated VF in a closed-chest, closed-pericardium model in 6 swine. Within 1 minute of untreated VF, mean right ventricular volume increased by 29% but did not increase thereafter. During the first 5 minutes of untreated VF, mean left ventricular volume increased by 34%. Between 20 and 30 minutes of VF, stone heart occurred as manifested by dramatic thickening of the myocardium and concomitant substantial decreases in left ventricular volume. In this closed-chest swine model of VF, substantial right ventricular volume changes occurred early and did not result in smaller left ventricular volumes. The changes in ventricular volumes before the late development of stone heart do not explain why defibrillation from brief duration VF (<5 minutes) typically results in a pulsatile rhythm with return of spontaneous circulation, whereas defibrillation from prolonged VF (5 to 15 minutes) does not.
Ylitalo, Pekka; Jokinen, Eero; Lauerma, Kirsi; Holmström, Miia; Pitkänen-Argillander, Olli M
2018-02-01
Right ventricular dysfunction in patients with tetralogy of Fallot and significant pulmonary regurgitation may lead to systolic dysfunction of the left ventricle due to altered ventricular interaction. We were interested in determining whether chronic pulmonary regurgitation affects the preload of the left ventricle. In addition, we wanted to study whether severe chronic pulmonary regurgitation would alter the preload of the left ventricle when compared with patients having preserved pulmonary valve annulus. The study group comprised 38 patients with tetralogy of Fallot who underwent surgical repair between 1990 and 2003. Transannular patching was required in 21 patients to reconstruct the right ventricular outflow tract. Altogether, 48 age- and gender-matched healthy volunteers were recruited. Cardiac MRI was performed on all study patients to assess the atrial and ventricular volumes and function. Severe pulmonary regurgitation (>30 ml/m2) was present in 13 patients, of whom 11 had a transannular patch, but only two had a preserved pulmonary valve annulus. The ventricular preload volumes from both atria were significantly reduced in patients with severe pulmonary regurgitation, and left ventricular stroke volumes (44.1±4.7 versus 58.9±10.7 ml/m2; p<0.0001) were smaller compared with that in patients with pulmonary regurgitation <30 ml/m2 or in controls. In patients with tetralogy of Fallot, severe pulmonary regurgitation has a significant effect on volume flow through the left atrium. Reduction in left ventricular preload volume may be an additional factor contributing to left ventricular dysfunction.
Yambe, T; Hashimoto, H; Kobayashi, S; Sonobe, T; Naganuma, S; Nanka, S S; Matsuki, H; Yoshizawa, M; Tabayashi, K; Takayasu, H; Takeda, H; Nitta, S
1997-01-01
We have developed a vibrating flow pump (VFP) that can generate oscillated blood flow with a relatively high frequency (10-50 Hz) for a totally implantable ventricular assist system (VAS). To evaluate the newly developed VAS, left heart bypasses, using the VFP, were performed in chronic animal experiments. Hemodynamic parameters were recorded in a data recorder in healthy adult goats during an awake condition and analyzed in a personal computer system through an alternating-direct current converter. Basic performance of the total system with a transcutaneous energy transmission system were satisfactory. During left ventricular assistance with the VFP, Mayer wave fluctuations of hemodynamics were decreased in the power spectrum, the fractal dimensions of the hemodynamics were significantly decreased, and peripheral vascular resistance was significantly decreased. These results suggest that cardiovascular regulatory nonlinear dynamics, which mediate the hemodynamics, may be affected by left ventricular bypass with oscillated flow. The decreased power of the Mayer wave in the spectrum caused the limit cycle attractor of the hemodynamics and decreased peripheral resistance. These results suggest that this newly developed VAS is useful for the totally implantable system with unique characteristics that can control hemodynamic properties.
Effect of the mitral valve on diastolic flow patterns
DOE Office of Scientific and Technical Information (OSTI.GOV)
Seo, Jung Hee; Vedula, Vijay; Mittal, Rajat, E-mail: mittal@jhu.edu
2014-12-15
The leaflets of the mitral valve interact with the mitral jet and significantly impact diastolic flow patterns, but the effect of mitral valve morphology and kinematics on diastolic flow and its implications for left ventricular function have not been clearly delineated. In the present study, we employ computational hemodynamic simulations to understand the effect of mitral valve leaflets on diastolic flow. A computational model of the left ventricle is constructed based on a high-resolution contrast computed-tomography scan, and a physiological inspired model of the mitral valve leaflets is synthesized from morphological and echocardiographic data. Simulations are performed with a diodemore » type valve model as well as the physiological mitral valve model in order to delineate the effect of mitral-valve leaflets on the intraventricular flow. The study suggests that a normal physiological mitral valve promotes the formation of a circulatory (or “looped”) flow pattern in the ventricle. The mitral valve leaflets also increase the strength of the apical flow, thereby enhancing apical washout and mixing of ventricular blood. The implications of these findings on ventricular function as well as ventricular flow models are discussed.« less
NASA Astrophysics Data System (ADS)
Convertino, V. A.; Koenig, S. C.; Krotov, V. P.; Fanton, J. W.; Korolkov, V. I.; Trambovetsky, E. V.; Ewert, D. L.; Truzhennikov, A.; Latham, R. D.
Central circulatory hemodynamic responses were measured before and during the initial 9 days of a 12-day 10 ° head-down tilt (HDT) in 4 flight-sized juvenile rhesus monkeys who were surgically instrumented with a variety of intrathoracic catheters and blood flow sensors to assess the effects of simulated microgravity on central circulatory hemodynamics. Each subject underwent measurements of aortic and left ventricular pressures, and aortic flow before and during HDT as well as during a passive head-up postural test before and after HDT. Heart rate, stroke volume, cardiac output, and left ventricular end-diastolic pressure were measured, and dP/dt and left ventricular elastance was calculated from hemodynamic measurements. The postural test consisted of 5 min of supine baseline control followed by 5 minutes of 90 ° upright tilt (HUT). Heart rate, stroke volume, cardiac output, and left ventricular end-diastolic pressure showed no consistent alterations during HDT. Left ventricular elastance was reduced in all animals throughout HDT, indicating that cardiac compliance was increased. HDT did not consistently alter left ventricular +dP/dt, indicating no change in cardiac contractility. Heart rate during the post-HDT HUT postural test was elevated compared to pre-HDT while post-HDT cardiac output was decreased by 52% as a result of a 54% reduction in stroke volume throughout HUT. Results from this study using an instrumented rhesus monkey suggest that exposure to microgravity may increase ventricular compliance without alterating cardiac contractility. Our project supported the notion that an invasively-instrumented animal model should be viable for use in spaceflight cardiovascular experiments to assess potential changes in myocardial function and cardiac compliance.
NASA Technical Reports Server (NTRS)
Convertino, V. A.; Koenig, S. C.; Krotov, V. P.; Fanton, J. W.; Korolkov, V. I.; Trambovetsky, E. V.; Ewert, D. L.; Truzhennikov, A.; Latham, R. D.
1998-01-01
Central circulatory hemodynamic responses were measured before and during the initial 9 days of a 12-day 10 degrees head-down tilt (HDT) in 4 flight-sized juvenile rhesus monkeys who were surgically instrumented with a variety of intrathoracic catheters and blood flow sensors to assess the effects of simulated microgravity on central circulatory hemodynamics. Each subject underwent measurements of aortic and left ventricular pressures, and aortic flow before and during HDT as well as during a passive head-up postural test before and after HDT. Heart rate, stroke volume, cardiac output, and left ventricular end-diastolic pressure were measured, and dP/dt and left ventricular elastance was calculated from hemodynamic measurements. The postural test consisted of 5 min of supine baseline control followed by 5 minutes of 90 degrees upright tilt (HUT). Heart rate, stroke volume, cardiac output, and left ventricular end-diastolic pressure showed no consistent alterations during HDT. Left ventricular elastance was reduced in all animals throughout HDT, indicating that cardiac compliance was increased. HDT did not consistently alter left ventricular +dP/dt, indicating no change in cardiac contractility. Heart rate during the post-HDT HUT postural test was elevated compared to pre-HDT while post-HDT cardiac output was decreased by 52% as a result of a 54% reduction in stroke volume throughout HUT. Results from this study using an instrumented rhesus monkey suggest that exposure to microgravity may increase ventricular compliance without alternating cardiac contractility. Our project supported the notion that an invasively-instrumented animal model should be viable for use in spaceflight cardiovascular experiments to assess potential changes in myocardial function and cardiac compliance.
Implantation of a HeartMate II left ventricular assist device via left thoracotomy.
Cho, Yang Hyun; Deo, Salil V; Schirger, John A; Pereira, Naveen L; Stulak, John M; Park, Soon J
2012-11-01
Left thoracotomy was used as an approach for the implantation of pulsatile ventricular assist devices. Avoiding the standard approach of median sternotomy is attractive in patients undergoing complicated redo cardiac surgery, especially with prior mediastinal radiation. We report a case of the use of left thoracotomy for the implantation of the HeartMate II axial-flow pump. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Rennyson, Stephen L; Shah, Keyur B; Tang, Daniel G; Kasirajan, Vigneshwar; Pedram, Sammy; Cahoon, William; Malhotra, Rajiv
2013-01-01
Left ventricular support devices (LVADs) are associated with a propensity toward gastrointestinal bleeding. A postulated mechanism is related to gastrointestinal arteriovenous malformations secondary to nonpulsatile flow. We describe a case of LVAD-related, gastrointestinal bleeding successfully treated with a combination of subcutaneous and intramuscular depot formulations of octreotide.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cabrera Sole, Ricardo
Objective: The main objective of this study was to evaluate the effects of the treatment with eprosartan on cardiac hypertrophy in hypertensive patients using the echocardiogram to measure the hypertrophy of left ventricle. We studied 60 untreated patients diagnosed of mild to moderate hypertension which received after the diagnosis 600 mg/day of eprosartan, a novel direct angiotensin inhibitor recently introduced to treat hypertension. All patients were submitted to a standard echocardiographic study before the treatment and after 6 months of it We evaluated by echocardiogram the following parameters: left ventricular septum and posterior wall thickness, left ventricular mass, E/A indexmore » of mitral flow considering abnormal when this index was less than 1, and left ventricular ejection fraction. Results: at the beginning we found a systolic/diastolic pressures of 165{+-}9/ 96{+-}4 mmHg compared with the end of study of 124{+-}2/79{+-}3 mmHg (p<0.05). Septum and posterior wall thickness were respectively at baseline 13.2{+-}2 and 12.1{+-}1.1 mmHg and at the end 11.5{+-}1.2 and 10.5{+-}1.3 mmHg (p<0.05 for both of them). The E/A mitral flow index was less than 1 at baseline in 45 patients compared with 19 patients after treatment (p<0.05). Respect to left ventricular mass we found at the beginning 232{+-}7.5 gr., compared to 194{+-}9 gr., at the end of this study (p<0.05). We did not find any significant differences regarding left ventricular ejection fraction between both groups. Conclusions: we can remark that eprosartan is a very useful drug to reduce not only blood pressure but also left ventricular hypertrophy and improve left ventricular diastolic function in patients with essential hypertension according with parameters measured with non invasive methods.« less
Liu, Ying; Zhang, Haowei; Zhang, Hang
2015-12-01
The early damage detection and evaluation are of great significance in treatment and prognosis to the left ventricular function for children with tumor. In this paper, it is reported that the early damage of the left ventricular function was observed by pulsed wave Doppler (PWD) and tissue Doppler imaging (TDI) in our laboratory. Eighty children half a year to fourteen years old were included in this study. The cardiac function indices in chemotherapy group and control group were measured and compared. The results showed that there was significant difference in mitral and tricuspid annulus flow spectrum between the two groups. Compared with PWD,TDI is more prompt, objective and accurate in detecting early damage of left ventricular function in children with tumor. And TDI is a good method for early identification of ventricular function damage in children with tumor.
Markus, Marcello Ricardo Paulista; Stritzke, Jan; Lieb, Wolfgang; Mayer, Björn; Luchner, Andreas; Döring, Angela; Keil, Ulrich; Hense, Hans-Werner; Schunkert, Heribert
2008-10-01
It is unclear whether persistent prehypertension causes structural or functional alterations of the heart. We examined echocardiographic data of 1005 adults from a population-based survey at baseline in 1994/1995 and at follow-up in 2004/2005. We compared individuals who had either persistently normal (<120 mmHg systolic and <80 mmHg diastolic, n = 142) or prehypertensive blood pressure (120-139 mmHg or 80-89 mmHg, n = 119) at both examinations using multivariate regression modeling. Over 10 years, left ventricular end-diastolic diameters were stable and did not differ between the two groups. However, the prehypertensive blood pressure group displayed more pronounced ageing-related increases of left ventricular wall thickness (+4.7 versus +11.9%, P < 0.001) and left ventricular mass (+8.6 versus +15.7%, P = 0.006). Prehypertension was associated with a raised incidence of left ventricular concentric remodeling (adjusted odds ratio 10.7, 95% confidence interval 2.82-40.4) and left ventricular hypertrophy (adjusted odds ratio 5.33, 1.58-17.9). The ratio of early and late diastolic peak transmitral flow velocities (E/A) decreased by 7.7% in the normal blood pressure versus 15.7% in the prehypertensive blood pressure group (P = 0.003) and at follow-up the ratio of early diastolic peak transmitral flow and early diastolic peak myocardial relaxation velocities (E/EM) was higher (9.1 versus 8.5, P = 0.031) and left atrial size was larger (36.5 versus 35.3 mm, P = 0.024) in the prehypertensive blood pressure group. Finally, the adjusted odds ratio for incident diastolic dysfunction was 2.52 (1.01-6.31) for the prehypertensive blood pressure group. Persistent prehypertension accelerates the development of hypertrophy and diastolic dysfunction of the heart.
Bartoli, Carlo R.; Rogers, Benjamin D.; Ionan, Constantine E.; Koenig, Steven C.; Pantalos, George M.
2013-01-01
OBJECTIVE Counterpulsation with an intraaortic balloon pump (IABP) has not achieved the same successes or clinical use in pediatric patients as in adults. In a pediatric animal model, IABP efficacy was investigated to determine whether IABP timing with a high-fidelity blood pressure signal may improve counterpulsation therapy versus a low-fidelity signal. METHODS In Yorkshire piglets (n=19, 13.0±0.5 kg) with coronary ligation-induced acute ischemic left ventricular failure, pediatric IABPs (5 or 7cc) were placed in the descending thoracic aorta. Inflation and deflation were timed with traditional criteria from low-fidelity (fluid-filled) and high-fidelity (micromanometer) blood pressure signals during 1:1 support. Aortic, carotid, and coronary hemodynamics were measured with pressure and flow transducers. Myocardial oxygen consumption was calculated from coronary sinus and arterial blood samples. Left ventricular myocardial blood flow and end-organ blood flow were measured with microspheres. RESULTS Despite significant suprasystolic diastolic augmentation and afterload reduction at heart rates of 105±3bmp, left ventricular myocardial blood flow, myocardial oxygen consumption, the myocardial oxygen supply/demand relationship, cardiac output, and end-organ blood flow did not change. Statistically significant end-diastolic coronary, carotid, and aortic flow reversal occurred with IABP deflation. Inflation and deflation timed with a high-fidelity versus low-fidelity signal did not attenuate systemic flow reversal or improve the myocardial oxygen supply/demand relationship. CONCLUSIONS Systemic end-diastolic flow reversal limited counterpulsation efficacy in a pediatric model of acute left ventricular failure. Adjustment of IABP inflation and deflation timing with traditional criteria and a high-fidelity blood pressure waveform did not improve IABP efficacy or attenuate flow reversal. End-diastolic flow reversal may limit the efficacy of IABP counterpulsation therapy in pediatric patients with traditional timing criteria. Investigation of alternative deflation timing strategies is warranted. PMID:24139614
Bartoli, Carlo R; Rogers, Benjamin D; Ionan, Constantine E; Pantalos, George M
2014-05-01
Counterpulsation with an intra-aortic balloon pump (IABP) has not achieved the same success or clinical use in pediatric patients as in adults. In a pediatric animal model, IABP efficacy was investigated to determine whether IABP timing with a high-fidelity blood pressure signal may improve counterpulsation therapy versus a low-fidelity signal. In Yorkshire piglets (n = 19; weight, 13.0 ± 0.5 kg) with coronary ligation-induced acute ischemic left ventricular failure, pediatric IABPs (5 or 7 mL) were placed in the descending thoracic aorta. Inflation and deflation were timed with traditional criteria from low-fidelity (fluid-filled) and high-fidelity (micromanometer) blood pressure signals during 1:1 support. Aortic, carotid, and coronary hemodynamics were measured with pressure and flow transducers. Myocardial oxygen consumption was calculated from coronary sinus and arterial blood samples. Left ventricular myocardial blood flow and end-organ blood flow were measured with microspheres. Despite significant suprasystolic diastolic augmentation and afterload reduction at heart rates of 105 ± 3 beats per minute, left ventricular myocardial blood flow, myocardial oxygen consumption, the myocardial oxygen supply/demand relationship, cardiac output, and end-organ blood flow did not change. Statistically significant end-diastolic coronary, carotid, and aortic flow reversal occurred with IABP deflation. Inflation and deflation timed with a high-fidelity versus low-fidelity signal did not attenuate systemic flow reversal or improve the myocardial oxygen supply/demand relationship. Systemic end-diastolic flow reversal limited counterpulsation efficacy in a pediatric model of acute left ventricular failure. Adjustment of IABP inflation and deflation timing with traditional criteria and a high-fidelity blood pressure waveform did not improve IABP efficacy or attenuate flow reversal. End-diastolic flow reversal may limit the efficacy of IABP counterpulsation therapy in pediatric patients with traditional timing criteria. Investigation of alternative deflation timing strategies is warranted. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Chronic outpatient management of patients with a left ventricular assist device
Franzwa, Jennifer
2015-01-01
The use of mechanical circulatory support (MCS) as treatment for advanced heart failure (HF) has grown exponentially over the past 15 years. The continuous flow left ventricular assist device (CF-LVAD) has become the most used form of MCS in advanced HF, especially since approval of use as destination therapy (DT) and with the lack of organ availability. Long-term survival has improved and diligent outpatient management is thus particularly critical to achieve optimal outcomes. This review will discuss outpatient management strategies for patients with HF and a left ventricular assist device (LVAD). PMID:26793331
McKellar, Stephen H; Deo, Salil; Daly, Richard C; Durham, Lucian A; Joyce, Lyle D; Stulak, John M; Park, Soon J
2014-01-01
A competent aortic valve is essential to providing effective left ventricular assist device support. We have adopted a practice of central aortic valve closure by placing a simple coaptation stitch at left ventricular assist device implantation in patients with significant aortic insufficiency. We conducted a follow-up study to evaluate the efficacy and durability of this procedure. The study included patients who had undergone continuous flow left ventricular assist device implantation. The patients were divided into 2 groups, those who did not require any aortic procedure because the valve was competent and those who underwent central aortic valve closure for mild or greater aortic regurgitation. The clinical endpoints were mortality, progression or recurrence of aortic insufficiency, and reoperation for aortic valve pathologic features. Aortic insufficiency was measured qualitatively from mild to severe on a scale of 0 to 5. A total of 123 patients received continuous flow left ventricular assist devices from February 2007 to August 2011. Of those, 18 (15%) underwent central aortic valve closure at left ventricular assist device implantation because of significant aortic insufficiency (1.8 ± 1.4) and 105 who did not (competent aortic valve, 0.15 ± 0.43; P < .01). At follow-up (median, 312 days; range, 0-1429 days), the mean aortic insufficiency score remained low for the patients with central aortic valve closure (0.27 ± 0.46) in contrast to those without central aortic valve closure who experienced aortic insufficiency progression (0.78 ± 0.89; P = .02). In addition, the proportion of patients with more than mild aortic insufficiency was significantly less in the central aortic valve closure group (0% vs 18%; P = .05). The patients in the central aortic valve closure group were significantly older and had a greater incidence of renal failure at baseline. The 30-day mortality was greater in the central aortic valve closure group, but the late survival was similar between the 2 groups. No reoperations were required for recurrent aortic insufficiency. The results of our study have shown that repair of aortic insufficiency with a simple central coaptation stitch is effective and durable in left ventricular assist device-supported patients, with follow-up extending into 2 years. Although aortic insufficiency progressed over time in those with minimal native valve regurgitation initially, no such progression was noted in those with central aortic valve closure. Additional investigation is needed to evaluate whether prophylactic central aortic valve closure should be performed at left ventricular assist device implantation to avoid problematic aortic regurgitation developing over time, in particular in patients undergoing left ventricular assist device implantation for life-long (destination therapy) support. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Honda, Takashi; Itatani, Keiichi; Takanashi, Manabu; Kitagawa, Atsushi; Ando, Hisashi; Kimura, Sumito; Oka, Norihiko; Miyaji, Kagami; Ishii, Masahiro
2017-10-01
Vector flow mapping is a novel echocardiographic flow visualization method, and it has enabled us to quantitatively evaluate the energy loss in the left ventricle (intraventricular energy loss). Although intraventricular energy loss is assumed to be a part of left ventricular workload itself, it is unclear what this parameter actually represents. The aim of the present study was to elucidate the characteristics of intraventricular energy loss. We enrolled 26 consecutive children with ventricular septal defect (VSD). On echocardiography vector flow mapping, intraventricular energy loss was measured in the apical 3-chamber view. We measured peak energy loss and averaged energy loss in the diastolic and systolic phases, and subsequently compared these parameters with catheterization parameters and serum brain natrium peptide (BNP) level. Diastolic, peak, and systolic energy loss were strongly and positively correlated with right ventricular systolic pressure (r=0.76, 0.68, and 0.56, p<0.0001, = 0.0001, and 0.0029, respectively) and right ventricular end diastolic pressure (r=0.55, 0.49, and 0.49, p=0.0038, 0.0120, and 0.0111, respectively). In addition, diastolic, peak, and systolic energy loss were significantly correlated with BNP (r=0.75, 0.69 and 0.49, p<0.0001, < 0.0001, and=0.0116, respectively). In children with VSD, elevated right ventricular pressure is one of the factors that increase energy loss in the left ventricle. The results of the present study encourage further studies in other study populations to elucidate the characteristics of intraventricular energy loss for its possible clinical application. Copyright © 2017 Elsevier B.V. All rights reserved.
Marks, J D; Pantalos, G M; Long, J W; Kinoshita, M; Everett, S D; Olsen, D B
1999-01-01
Unlike the mechanisms of intraaortic balloon pump (IABP) support, the mechanisms by which transvalvular axial flow Hemopump (HP) support benefit dysfunctional myocardium are less clearly understood. To help elucidate these mechanisms, hemodynamic, metabolic, and mechanical indexes of left ventricular function were measured during conditions of control, ischemic dysfunction, IABP support, and HP support. A large animal (calf) model of left ventricular dysfunction was created with multiple coronary ligations. Peak intraventricular pressure increased with HP support and decreased with IABP support. Intramyocardial pressure (an indicator of intramyocardial stress), time rate of pressure change (an indicator of contractility), and left ventricular myocardial oxygen consumption decreased with IABP and HP support. Left ventricular work decreased with HP support and increased with IABP support. During HP support, indexes of wall stress, work, and contractility, all primary determinants of oxygen consumption, were reduced. During IABP support, indexes of wall stress and contractility were reduced and external work increased. These changes were attributed primarily to changes in ventricular preload, and geometry for HP support, and to a reduction in afterload for IABP support. These findings support the hypothesis that both HP and IABP support reduce intramyocardial stress development and the corresponding oxygen consumption, although via different mechanisms.
Park, Jun I K; Heikhmakhtiar, Aulia Khamas; Kim, Chang Hyun; Kim, Yoo Seok; Choi, Seong Wook; Song, Kwang Soup; Lim, Ki Moo
2018-05-22
Although it is important to analyze the hemodynamic factors related to the right ventricle (RV) after left ventricular assist device (LVAD) implantation, previous studies have focused only on the alteration of the ventricular shape and lack quantitative analysis of the various hemodynamic parameters. Therefore, we quantitatively analyzed various hemodynamic parameters related to the RV under normal, heart failure (HF), and HF incorporated with continuous flow LVAD therapy by using a computational model. In this study, we combined a three-dimensional finite element electromechanical model of ventricles, which is based on human ventricular morphology captured by magnetic resonance imaging (MRI) with a lumped model of the circulatory system and continuous flow LVAD function in order to construct an integrated model of an LVAD implanted-cardiovascular system. To induce systolic dysfunction, the magnitude of the calcium transient function under HF condition was reduced to 70% of the normal value, and the time constant was reduced by 30% of the normal value. Under the HF condition, the left ventricular end systolic pressure decreased, the left ventricular end diastolic pressure increased, and the pressure in the right atrium (RA), RV, and pulmonary artery (PA) increased compared with the normal condition. The LVAD therapy decreased the end-systolic pressure of the LV by 41%, RA by 29%, RV by 53%, and PA by 71%, but increased the right ventricular ejection fraction by 52% and cardiac output by 40%, while the stroke work was reduced by 67% compared with the HF condition without LVAD. The end-systolic ventricular tension and strain decreased with the LVAD treatment. LVAD enhances CO and mechanical unloading of the LV as well as those of the RV and prevents pulmonary hypertension which can be induced by HF.
Experimental study on the effect of an artificial cardiac valve on the left ventricular flow
NASA Astrophysics Data System (ADS)
Wang, JiangSheng; Gao, Qi; Wei, RunJie; Wang, JinJun
2017-09-01
The use of artificial valves to replace diseased human heart valves is currently the main solution to address the malfunctioning of these valves. However, the effect of artificial valves on the ventricular flow still needs to be understood in flow physics. The left ventricular flow downstream of a St. Jude Medical (SJM) bileaflet mechanical heart valve (BMHV), which is a widely implanted mechanical bileaflet valve, is investigated with time-resolved particle image velocimetry in the current work. A tilting-disk valve is installed on the aortic orifice to guarantee unidirectional flow. Several post-processing tools are applied to provide combined analyses of the physics involved in the ventricular flow. The triple jet pattern that is closely related to the characteristics of the bileaflet valve is discussed in detail from both Eulerian and Lagrangian views. The effects of large-scale vortices on the transportation of blood are revealed by the combined analysis of the tracking of Lagrangian coherent structures, the Eulerian monitoring of the shear stresses, and virtual dye visualization. It is found that the utilization of the SJM BMHV complicates the ventricular flow and could reduce the efficiency of blood transportation. In addition, the kinematics of the bileaflets is presented to explore the effects of flow structures on their motion. These combined analyses could elucidate the properties of SJM BMHV. Furthermore, they could provide new insights into the understanding of other complex blood flows.
Magder, Sheldon
2007-12-01
Discussions of cardiac physiology and pathophysiology most often emphasise the function of the left heart. However, right heart dysfunction plays an important role in critically ill patients and is often not recognised. This is probably because the role of the right ventricle is for generating flow more than pressure, and flow is not easy to evaluate. Of importance, when right ventricular function limits cardiac output, assessing left ventricular function gives little indication of overall cardiac performance. It has recently become evident that the right ventricle also has different genetic origins and characteristics from the left ventricle. The right and left ventricles interact through series effects, diastolic interactions and systolic interactions. The mechanisms of these, and their physiological and pathological significance are discussed.
Møller-Helgestad, Ole K; Poulsen, Christian B; Christiansen, Evald H; Lassen, Jens F; Ravn, Hanne B
2015-01-15
Cardiogenic shock as a complication to an acute myocardial infarction has an unacceptably high death rate that has not changed for the last 15years. Mortality is partly related to organ hypoperfusion and mechanical assist devices are used for the most severe cases but we do not know which assist device is the best option. Therefore, we have investigated how an IABP and an Impella®-pump influenced blood flow to the brain, heart and kidneys, in a closed-chest porcine model of severe left ventricular failure. 13 pigs were anesthetised and left ventricular failure was induced by occluding the proximal LAD for 45min followed by 30min of reperfusion. Blood flow was measured in the carotid artery, the LAD, and the renal artery. The Impella® and IABP were inserted via the femoral arteries, and the two devices were tested individually and combined after induction of heart failure. Carotid- (p=0.01) and renal blood flow (p=0.045) were higher on Impella®-support, compared to no support. None of the devices altered the blood flow in the LAD. Cardiac power output (p<0.005) and left ventricular work (p<0.00) were also higher on Impella®-support compared to no support. Haemodynamics and blood flow to the brain and kidneys were significantly better on Impella®-support, suggesting that the Impella® is superior to the IABP in a state of ischaemia induced left ventricular failure. These data, however, needs to be confirmed in a proper clinical trial with patients in cardiogenic shock. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Djordjevic-Dikic, Ana; Beleslin, Branko; Stepanovic, Jelena; Giga, Vojislav; Tesic, Milorad; Dobric, Milan; Stojkovic, Sinisa; Nedeljkovic, Milan; Vukcevic, Vladan; Dikic, Nenad; Petrasinovic, Zorica; Nedeljkovic, Ivana; Tomasevic, Miloje; Vujisic-Tesic, Bosiljka; Ostojic, Miodrag
2011-05-01
The aim of this study was to evaluate the relation of basal and hyperemic coronary flow with myocardial functional improvement in patients with previous myocardial infarction undergoing elective percutaneous coronary intervention (PCI). Coronary flow was measured using transthoracic Doppler echocardiography in 50 patients (41 men; mean age, 53 ± 8 years) with previous myocardial infarction before, 24 hours, and 3 months after elective PCI. Diastolic deceleration time (DDT) was measured from the peak diastolic velocity to the point of intercept of initial decay slope with baseline. Coronary flow reserve (CFR) was calculated as the ratio of hyperemic to basal peak diastolic flow velocities. In comparison with patients without improvements in left ventricular function, patients with recovered left ventricular function had longer DDTs before angioplasty (841 ± 286 vs. 435 ± 80 msec, P < .001). CFR was significantly higher in recovered compared with nonrecovered patients (2.60 ± 0.70 vs. 2.16 ± 0.34, P = .034) 24 hours after PCI. Global and regional wall motion scores before PCI, end-diastolic and end-systolic volumes, and CFR 24 hours after PCI and DDT before PCI were univariate predictors of left ventricular functional recovery. By multivariate analysis, DDT and regional wall motion score before PCI were independent predictors of left ventricular recovery in the follow-up period (P = .003 and P = .007, respectively). In patients with previous myocardial infarction undergoing elective PCI, evaluation of basal coronary flow pattern and measurement of DDT before angioplasty may predict functional improvement of myocardium in the follow-up period and could be useful quantitative parameters in the evaluation of potential improvement in myocardial function. Copyright © 2011 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.
Shah, Keyur B; Gunda, Sampath; Emani, Sitaramesh; Kanwar, Manreet K; Uriel, Nir; Colombo, Paolo C; Uber, Patricia A; Sears, Melissa L; Chuang, Joyce; Farrar, David J; Brophy, Donald F; Smallfield, George B
2017-11-01
Gastrointestinal (GI) bleeding is one of the most common complications after continuous-flow left ventricular assist device implantation. More than one third of patients with incident bleed go on to develop recurrent GI bleeding. Octreotide, a somatostatin analog, is proposed to reduce the risk of recurrent GI bleeding in this population. This multicenter, retrospective analysis evaluated 51 continuous-flow left ventricular assist device patients who received secondary prophylaxis with octreotide after their index GI bleed from 2009 to 2015. All patients had a hospitalization for GI bleed and received octreotide after discharge. Patient demographics, medical and medication history, and clinical characteristics of patients who rebled after receiving octreotide were compared with non-rebleeders. These data were also compared with matched historical control patients previously enrolled in the HMII (HeartMate II) clinical trials, none of whom received octreotide, to provide a context for the bleeding rates. Twelve patients (24%) who received secondary octreotide prophylaxis developed another GI bleed, whereas 39 (76%) did not. There were similar intergroup demographics; however, significantly more bleeders had a previous GI bleeding history before left ventricular assist device placement (33% versus 5%; P =0.02) and greater frequency of angiodysplasia confirmed during endoscopy (58% versus 23%; P =0.03). Fewer patients in this study experienced a recurrent GI bleed compared with a matched historical control group that did not receive octreotide (24% versus 43%; P =0.04). Patients with continuous-flow left ventricular assist device receiving secondary prophylaxis with octreotide had a significantly lower GI bleed recurrence compared with historical controls not treated with octreotide. Additional prospective studies are needed to confirm these data. © 2017 American Heart Association, Inc.
Kato, Atsuko; Drolet, Christian; Yoo, Shi-Joon; Redington, Andrew N; Grosse-Wortmann, Lars
2016-06-07
The left pulmonary artery (LPA) contributes more than the right (RPA) to total pulmonary regurgitation (PR) in patients after tetralogy of Fallot (TOF) repair, but the mechanism of this difference is not well understood. This study aimed to analyze the interplay between heart and lung size, mediastinal geometry, and differential PR. Forty-eight Cardiovascular Magnetic Resonance (CMR) studies in patients after TOF repair were analyzed. In addition to the routine blood flow and ventricular volume quantification cardiac angle between the thoracic anterior-posterior line and the interventricular septum, right and left lung areas as well as right and left hemithorax areas were measured on an axial image. Statistical analysis was performed to compare flow parameters between RPA and LPA and to assess correlation among right ventricular volume, pulmonary blood flow parameters and lung area. There was no difference between LPA and RPA diameters. The LPA showed significantly less total forward flow (2.49 ± 0.87 L/min/m(2) vs 2.86 ± 0.89 L/min/m(2); p = 0.02), smaller net forward flow (1.40 ± 0.51 vs 1.89 ± 0.60 mL/min/m(2); p = <0.001), and greater regurgitant fraction (RF) (34 ± 10 % vs 43 ± 12 %; p = 0.001) than the RPA. There was no difference in regurgitant flow volume between RPA and LPA (p = 0.29). Indexed right ventricular end-diastolic volume (RVEDVi) correlated with LPA RF (R = 0.48, p < 0.001), but not with RPA RF (p = 0.09). Larger RVEDVi correlated with a more leftward cardiac axis (R = 0.46, p < 0.001) and with smaller left lung area (R = -0.58, p < 0.001). LPA RF, but not RPA RF, correlated inversely with left lung area (R = -0.34, p = 0.02). The follow-up CMRs in 20 patients showed a correlation of the rate of RV enlargement with the rates of LPA RF worsening (R = 0.50, p = 0.03), and of increasing left lung compression (R = -0.55, p = 0.012). An enlarged and levorotated heart is associated with left lung compression and impaired flow into the left lung.
Left atrial booster function in valvular heart disease.
Heidenreich, F P; Shaver, J A; Thompson, M E; Leonard, J J
1970-09-01
This study was designed to assess atrial booster pump action in valvular heart disease and to dissect booster pump from reservoir-conduit functions. In five patients with aortic stenosis and six with mitral stenosis, sequential atrioventricular (A-V) pacing was instituted during the course of diagnostic cardiac catheterization. Continuous recording of valvular gradient allowed estimation of flow for each cardiac cycle by transposition of the Gorlin formula. Left ventricular ejection time and left ventricular stroke work in aortic stenosis or left ventricular mean systolic pressure in mitral stenosis were also determined. Control observations were recorded during sequential A-V pacing with well-timed atrial systole. Cardiac cycles were then produced with no atrial contraction but undisturbed atrial reservoir function by intermittently interrupting the atrial pacing stimulus during sequential A-V pacing. This intervention significantly reduced valvular gradient, flow, left ventricular ejection time, and left ventricular mean systolic pressure or stroke work. Cardiac cycles were then produced with atrial booster action eliminated by instituting synchronous A-V pacing. The resultant simultaneous contraction of the atrium and ventricle not only eliminated effective atrial systole but also placed atrial systole during the normal period of atrial reservoir function. This also significantly reduced all the hemodynamic measurements. However, comparison of the magnitude of change from these two different pacing interventions showed no greater impairment of hemodynamic state when both booster pump action and reservoir function were impaired than when booster pump action alone was impaired. The study confirms the potential benefit of well placed atrial booster pump action in valvular heart disease in man.
Maltais, Simon; Topilsky, Yan; Tchantchaleishvili, Vakhtang; McKellar, Stephen H; Durham, Lucian A; Joyce, Lyle D; Daly, Richard C; Park, Soon J
2012-06-01
The HeartMate II (Thoratec Corp, Pleasanton, Calif) continuous-flow left ventricular assist device has emerged as the standard of care for patients with advanced heart failure. The objective of this study was to assess the safety and early effectiveness of concomitant tricuspid valve procedures in patients undergoing implantation of a HeartMate II device. From February 2007 to April 2010, 83 patients underwent HeartMate II left ventricular assist device implantation. Of these, 37 patients had concomitant tricuspid valve procedures (32 repairs, 5 replacements) for severe tricuspid regurgitation. The effects of a tricuspid valve procedure on tricuspid regurgitation and right ventricular remodeling were assessed comparing echocardiographic findings at baseline and 30 days after left ventricular assist device implantation. Overall survival was also compared. Patients undergoing a concomitant tricuspid valve procedure had more tricuspid regurgitation (vena contracta, 5.6 ± 2.1 mm vs 2.9 ± 2.0 mm; P < .001), worse right ventricular dysfunction (right ventricular end-diastolic area, 33.6 ± 6.2 mm vs 31.6 ± 8.5 mm; P = .05), higher mean right atrial pressure (17.4 ± 7.1 mm Hg vs 14.9 ± 5.1 mm Hg; P = .03), and a higher Kormos score (2.6 ± 2.1 vs 1.2 ± 1.4; P = .0008) preoperatively. One month after surgery, tricuspid regurgitation was worse in patients who underwent left ventricular assist device implantation alone (+18.6%), whereas it improved significantly in patients undergoing a concomitant tricuspid valve procedure (-50.2%) (P = .005). A corresponding significant reduction in right ventricular end-diastolic area (33.6% ± 6.2% vs 30.1% ± 9.7%; P = .03) and a trend toward better right ventricular function (55.5% ± 79.7% vs 35.7% ± 60.5%; P = .28) were noted in patients undergoing a concomitant tricuspid valve procedure. Survival was comparable between the 2 groups. In patients with severe tricuspid regurgitation undergoing left ventricular assist device implantation, a concomitant tricuspid valve procedure effectively reduces tricuspid regurgitation and promotes reverse remodeling of the right ventricle. Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Krams, R; Sipkema, P; Westerhof, N
1990-06-01
In this study on the isolated, maximally vasodilated, blood-perfused cat heart we investigated the relation between left ventricular developed pressure (delta Piv) and coronary oscillatory flow amplitude (diastolic minus systolic flow, delta F) at different levels of constant perfusion pressure (Pp). We hypothesized that the effect of cardiac contraction on the phasic flow results from the changing elastic properties of cardiac muscle. The coronary vessel compartment can, as can the left ventricular lumen compartment, be described by a time-varying elastance. This concept predicts that the effect of left ventricular pressure on delta F is small, whereas the effect of Pp is considerable. Both the waterfall model and the intramyocardial pump model predict the inverse. The relation between delta Piv and delta F at a Pp of 10 kPa is delta F = (4.71 +/- 3.08).delta Piv + 337 +/- 75 (slope in ml.min-1.100 g-1.kPa-1 and intercept in ml.min-1.100 g-1; n = 7); the relation between (constant levels of) Pp and delta F at a constant delta Piv of 10 kPa is delta F = 51.Pp + 211 (slope in ml.min-1.100 g-1.kPa-1 and intercept in ml.min-1.100 g-1; n = 6). The differences in slope are best predicted by the time-varying elastance concept.
Echocardiographic assessment of left ventricular diastolic function.
Pirat, Bahar; Zoghbi, William A
2007-09-01
Assessment of diastolic function and left ventricular filling pressures in the setting of both normal and reduced systolic function is of major importance particularly in patients with dyspnea. Since multiple echocardiography parameters are used to assess diastolic function each with some limitations, a comprehensive approach should be applied. Transmitral Doppler flow should be evaluated in combination with newer, less load dependent Doppler techniques. Tissue Doppler imaging provides accurate, well validated data regarding diastolic properties and filling pressures of the left ventricle. Tissue Doppler imaging should be the part of a routine echocardiography study due to its ease of use and high reproducibility. Pulmonary vein Doppler and flow propagation velocity should be incorporated into the evaluation when needed.
Shehab, Sajad; Allida, Sabine M; Davidson, Patricia M; Newton, Phillip J; Robson, Desiree; Jansz, Paul C; Hayward, Christopher S
Right ventricular failure after left ventricular assist device (LVAD) implantation is associated with high mortality. Management remains limited to pharmacologic therapy and temporary mechanical support. Delayed right ventricular assist device (RVAD) support after LVAD implantation is associated with poorer outcomes. With the advent of miniaturized, durable, continuous flow ventricular assist device systems, chronic RVAD and biventricular assist device (BiVAD) support has been used with some success. The purpose of this study was to assess combined BiVAD and LVAD with delayed RVAD support within a four-elemental mock circulatory loop (MCL) simulating the human cardiovascular system. Our hypothesis was that delayed continuous flow RVAD (RVAD) would produce similar hemodynamic and flow parameters to those of initial BiVAD support. Using the MCL, baseline biventricular heart failure with elevated right and left filling pressures with low cardiac output was simulated. The addition of LVAD within a biventricular configuration improved cardiac output somewhat, but was associated with persistent right heart failure with elevated right-sided filling pressures. The addition of an RVAD significantly improved LVAD outputs and returned filling pressures to normal throughout the circulation. In conclusion, RVAD support successfully restored hemodynamics and flow parameters of biventricular failure supported with isolated LVAD with persistent elevated right atrial pressure.
Arvidsson, Per M; Töger, Johannes; Heiberg, Einar; Carlsson, Marcus; Arheden, Håkan
2013-05-15
Kinetic energy (KE) of atrial blood has been postulated as a possible contributor to ventricular filling. Therefore, we aimed to quantify the left (LA) and right (RA) atrial blood KE using cardiac magnetic resonance (CMR). Fifteen healthy volunteers underwent CMR at 3 T, including a four-dimensional phase-contrast flow sequence. Mean LA KE was lower than RA KE (1.1 ± 0.1 vs. 1.7 ± 0.1 mJ, P < 0.01). Three KE peaks were seen in both atria: one in ventricular systole, one during early ventricular diastole, and one during atrial contraction. The systolic LA peak was significantly smaller than the RA peak (P < 0.001), and the early diastolic LA peak was larger than the RA peak (P < 0.05). Rotational flow contained 46 ± 7% of total KE and conserved energy better than nonrotational flow did. The KE increase in early diastole was higher in the LA (P < 0.001). Systolic KE correlated with the combination of atrial volume and systolic velocity of the atrioventricular plane displacement (r(2) = 0.57 for LA and r(2) = 0.64 for RA). Early diastolic KE of the LA correlated with left ventricle (LV) mass (r(2) = 0.28), however, no such correlation was found in the right heart. This suggests that LA KE increases during early ventricular diastole due to LV elastic recoil, indicating that LV filling is dependent on diastolic suction. Right ventricle (RV) relaxation does not seem to contribute to atrial KE. Instead, RA KE generated during ventricular systole may be conserved in a hydraulic "flywheel" and transferred to the RV through helical flow, which may contribute to RV filling.
Lindholm, E E; Aune, E; Frøland, G; Kirkebøen, K A; Otterstad, J E
2014-06-01
The aim of this study was to define pre-operative echocardiographic data and explore if postoperative indices of cardiac function after open abdominal aortic surgery were affected by the anaesthetic regimen. We hypothesised that volatile anaesthesia would improve indices of cardiac function compared with total intravenous anaesthesia. Transthoracic echocardiography was performed pre-operatively in 78 patients randomly assigned to volatile anaesthesia and 76 to total intravenous anaesthesia, and compared with postoperative data. Pre-operatively, 16 patients (10%) had left ventricular ejection fraction < 46%. In 138 patients with normal left ventricular ejection fraction, 5/8 (62%) with left ventricular dilatation and 41/130 (33%) without left ventricular dilatation had evidence of left ventricular diastolic dysfunction (p < 0.001). Compared with pre-operative findings, significant increases in left ventricular end-diastolic volume, left atrial maximal volume, cardiac output, velocity of early mitral flow and early myocardial relaxation occurred postoperatively (all p < 0.001). The ratio of the velocity of early mitral flow to early myocardial relaxation remained unchanged. There were no significant differences in postoperative echocardiographic findings between patients anaesthetised with volatile anaesthesia or total intravenous anaesthesia. Patients had an iatrogenic surplus of approximately 4.1 l of fluid volume by the first postoperative day. N-terminal prohormone of brain natriuretic peptide increased on the first postoperative day (p < 0.001) and remained elevated after 30 days (p < 0.001) in both groups. Although postoperative echocardiographic alterations were most likely to be related to increased preload due to a substantial iatrogenic surplus of fluid, a component of peri-operative myocardial ischaemia cannot be excluded. Our hypothesis that volatile anaesthesia improved indices of cardiac function compared with total intravenous anaesthesia could not be verified. © 2014 The Association of Anaesthetists of Great Britain and Ireland.
Computational fluid dynamics analysis of a maglev centrifugal left ventricular assist device.
Burgreen, Greg W; Loree, Howard M; Bourque, Kevin; Dague, Charles; Poirier, Victor L; Farrar, David; Hampton, Edward; Wu, Z Jon; Gempp, Thomas M; Schöb, Reto
2004-10-01
The fluid dynamics of the Thoratec HeartMate III (Thoratec Corp., Pleasanton, CA, U.S.A.) left ventricular assist device are analyzed over a range of physiological operating conditions. The HeartMate III is a centrifugal flow pump with a magnetically suspended rotor. The complete pump was analyzed using computational fluid dynamics (CFD) analysis and experimental particle imaging flow visualization (PIFV). A comparison of CFD predictions to experimental imaging shows good agreement. Both CFD and experimental PIFV confirmed well-behaved flow fields in the main components of the HeartMate III pump: inlet, volute, and outlet. The HeartMate III is shown to exhibit clean flow features and good surface washing across its entire operating range.
Kobayashi, S; Owada, N; Yambe, T; Nitta, S; Fukuju, T; Hongoh, T; Hashimoto, H
1999-08-01
A vibrating flow pump (VFP) can generate high frequency oscillated blood flow within 10-30 Hz by the oscillation of its central tube. A totally implantable artificial heart using a VFP is being developed as a unique type of blood pump. In this study, left ventricular (LV) assist circulation was performed using a VFP. The total vascular resistance and driving frequency of the VFP were estimated from their relationship. The effect of oscillation on the vascular system was studied by the frequency analysis method and vascular impedance. Adult goats were anesthetized by halothane using an inhaler and a left fourth thoracotomy was performed. The inflow cannula was inserted into the left ventricle, and the outflow cannula was sutured to the descending aorta. The VFP and a centrifugal pump were set in parallel for alternation and comparison. The driving frequency of the VFP was changed and included 15, 20, 25, and 30 Hz. The hemodynamic parameters were continuously recorded during experiments by a digital audio tape (DAT) data recorder. The internal pressure of the left ventricular cavity and aortic pressure were monitored by the pressure manometers continuously. One hundred percent LV assistance was judged by the separation of LV and aortic pressure. The total vascular resistance was decreased by the start of operation of each pump. The decrease during flow using the VFP was not as large as that using a centrifugal pump (CP). The arterial input impedance during oscillated blood flow by the VFP showed a slow curve appearance. It was similar to the frequency characteristics curve of natural heart beats within the lower frequencies. The study of arterial impedance may be important for the estimation of the reflection of the pulsatile wave from the arterial branch, among other things.
Probe for production and measurement of acute mitral regurgitant flow in dog.
Kléber, A G; Simon, R; Rutishauser, W
1976-02-01
A probe for production and measurement of acute mitral regurgitation in dogs is described. It consists of a tube that is introduced into the mitral valve through the left atrial appendage. Regurgitant flow through the tube is measured by an electromagnetic device. Variation of flow and zero flow are achieved by narrowing or occluding the tube with a rubber cuff. In animals weighing 30-50 kg, the probe does not produce significant mitral stenosis and the mitral leaflets fit closely around the probe during ventricular systole. The instantaneous relationship between mitral regurgitant flow (MRF) and the gradient between left ventricular and left atrial pressure shows a marked delay of MRF at the beginning and end of regurgitation. This delay can be attributed to some extent to electrical phase lag and to the small movement of the probe relative to the mitral valve during the cardiac cycle. Measurement of regurgitant stroke volume is affected by this movement only to a small extent.
Transthoracic Ultrafast Doppler Imaging of Human Left Ventricular Hemodynamic Function
Osmanski, Bruno-Félix; Maresca, David; Messas, Emmanuel; Tanter, Mickael; Pernot, Mathieu
2016-01-01
Heart diseases can affect intraventricular blood flow patterns. Real-time imaging of blood flow patterns is challenging because it requires both a high frame rate and a large field of view. To date, standard Doppler techniques can only perform blood flow estimation with high temporal resolution within small regions of interest. In this work, we used ultrafast imaging to map in 2D human left ventricular blood flow patterns during the whole cardiac cycle. Cylindrical waves were transmitted at 4800 Hz with a transthoracic phased array probe to achieve ultrafast Doppler imaging of the left ventricle. The high spatio-temporal sampling of ultrafast imaging permits to rely on a much more effective wall filtering and to increase sensitivity when mapping blood flow patterns during the pre-ejection, ejection, early diastole, diastasis and late diastole phases of the heart cycle. The superior sensitivity and temporal resolution of ultrafast Doppler imaging makes it a promising tool for the noninvasive study of intraventricular hemodynamic function. PMID:25073134
Kutty, Shelby; Li, Ling; Danford, David A; Houle, Helene; Datta, Saurabh; Mancina, Joel; Xiao, Yunbin; Pedrizzetti, Gianni; Porter, Thomas R
2014-12-01
The purpose of this investigation was to test the hypothesis that flow patterns in the right ventricle are abnormal in patients with repaired tetralogy of Fallot (TOF). High-resolution echocardiographic contrast particle imaging velocimetry was used to investigate rotation intensity and kinetic energy dissipation of right ventricular (RV) flow in patients with TOF compared with normal controls. Forty-one subjects (16 with repaired TOF and varying degrees of RV dilation and 25 normal controls) underwent prospective contrast imaging using the lipid-encapsulated microbubble (Definity) on Sequoia systems. A mechanical index of 0.4, three-beat high-frame rate (>60 Hz) captures, and harmonic frequencies were used. Rotation intensity and kinetic energy dissipation of flow in the right and left ventricles were studied (Hyperflow). Ventricular volumes and ejection fractions in all subjects were derived from same-day cardiac magnetic resonance (CMR). Measurable planar maps were obtained for the left ventricle in 14 patients and the right ventricle in 10 patients among those with TOF and for the left ventricle in 23 controls and the right ventricle in 21 controls. Compared with controls, the TOF group had higher RV indexed end-diastolic volumes (117.8 ± 25.5 vs 88 ± 15.4 mL/m(2), P < .001) and lower RV ejection fractions (44.6 ± 3.6% vs 51.8 ± 3.6%, P < .001). Steady-streaming (heartbeat-averaged) flow rotation intensities were higher in patients with TOF for the left ventricle (0.4 ± 0.13 vs 0.29 ± 0.08, P = .012) and the right ventricle (0.53 ± 0.15 vs 0.26 ± 0.12, P < .001), whereas kinetic energy dissipation in TOF ventricles was lower (for the left ventricle, 0.51 ± 0.29 vs 1.52 ± 0.69, P < .001; for the right ventricle, 0.4 ± 0.24 vs 1.65 ± 0.91, P < .001). It is feasible to characterize RV and left ventricular flow parameters and planar maps in adolescents and adults with repaired TOF using echocardiographic contrast particle imaging velocimetry. Intraventricular flow patterns in the abnormal and/or enlarged right ventricle in patients with TOF differ from those in normal young adults. The rotation intensity and energy dissipation trends in this investigation suggest that they may be quantitative markers of RV and left ventricular compliance abnormalities in patients with repaired TOF. This hypothesis merits further investigation. Copyright © 2014 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
Modeling and control of a brushless DC axial flow ventricular assist device.
Giridharan, Guruprasad A; Skliar, Mikhail; Olsen, Donald B; Pantalos, George M
2002-01-01
This article presents an integrated model of the human circulatory system that incorporates circulatory support by a brushless DC axial flow ventricular assist device (VAD), and a feedback VAD controller designed to maintain physiologically sufficient perfusion. The developed integrated model combines a network type model of the circulatory system with a nonlinear dynamic model of the brushless DC pump We show that maintaining a reference differential pressure between the left ventricle and aorta leads to adequate perfusion for different pathologic cases, ranging from normal heart to left heart asystole, and widely varying physical activity scenarios from rest to exercise.
NASA Technical Reports Server (NTRS)
Yang, Hua; Jones, Michael; Shiota, Takahiro; Qin, Jian Xin; Kim, Yong Jin; Popovic, Zoran B.; Pu, Min; Greenberg, Neil L.; Cardon, Lisa A.; Eto, Yoko;
2002-01-01
BACKGROUND: The aim of our study was to quantitatively compare the changes and correlations between pulmonary venous flow variables and mean left atrial pressure (mLAP) under different loading conditions in animals with chronic mitral regurgitation (MR) and without MR. METHODS: A total of 85 hemodynamic conditions were studied in 22 sheep, 12 without MR as control (NO-MR group) and 10 with MR (MR group). We obtained pulmonary venous flow systolic velocity (Sv) and diastolic velocity (Dv), Sv and Dv time integrals, their ratios (Sv/Dv and Sv/Dv time integral), mLAP, left ventricular end-diastolic pressure, and MR stroke volume. We also measured left atrial a, x, v, and y pressures and calculated the difference between v and y pressures. RESULTS: Average MR stroke volume was 10.6 +/- 4.3 mL/beat. There were good correlations between Sv (r = -0.64 and r = -0.59, P <.01), Sv/Dv (r = -0.62 and r = -0.74, P <.01), and mLAP in the MR and NO-MR groups, respectively. Correlations were also observed between Dv time integral (r = 0.61 and r = 0.57, P <.01) and left ventricular end-diastolic pressure in the MR and NO-MR groups. In velocity variables, Sv (r = -0.79, P <.001) was the best predictor of mLAP in both groups. The sensitivity and specificity of Sv = 0 in predicting mLAP 15 mm Hg or greater were 86% and 85%, respectively. CONCLUSION: Pulmonary venous flow variables correlated well with mLAP under altered loading conditions in the MR and NO-MR groups. They may be applied clinically as substitutes for invasively acquired indexes of mLAP to assess left atrial and left ventricular functional status.
Moller, Thomas; Lindberg, Harald; Lund, May Brit; Holmstrom, Henrik; Dohlen, Gaute; Thaulow, Erik
2018-06-01
We previously demonstrated an abnormally high right ventricular systolic pressure response to exercise in 50% of adolescents operated on for isolated ventricular septal defect. The present study investigated the prevalence of abnormal right ventricular systolic pressure response in 20 adult (age 30-45 years) patients who underwent surgery for early ventricular septal defect closure and its association with impaired ventricular function, pulmonary function, or exercise capacity. The patients underwent cardiopulmonary tests, including exercise stress echocardiography. Five of 19 patients (26%) presented an abnormal right ventricular systolic pressure response to exercise ⩾ 52 mmHg. Right ventricular systolic function was mixed, with normal tricuspid annular plane systolic excursion and fractional area change, but abnormal tricuspid annular systolic motion velocity (median 6.7 cm/second) and isovolumetric acceleration (median 0.8 m/second2). Left ventricular systolic and diastolic function was normal at rest as measured by the peak systolic velocity of the lateral wall and isovolumic acceleration, early diastolic velocity, and ratio of early diastolic flow to tissue velocity, except for ejection fraction (median 53%). The myocardial performance index was abnormal for both the left and right ventricle. Peak oxygen uptake was normal (mean z score -0.4, 95% CI -2.8-0.3). There was no association between an abnormal right ventricular systolic pressure response during exercise and right or left ventricular function, pulmonary function, or exercise capacity. Abnormal right ventricular pressure response is not more frequent in adult patients compared with adolescents. This does not support the theory of progressive pulmonary vascular disease following closure of left-to-right shunts.
MacLea, H B; Boon, J A; Bright, J M
2013-01-01
Hypertrophic cardiomyopathy (HCM) is heterogeneous in both people and cats, with variability in the distribution of hypertrophy, hemodynamic characteristics, and Doppler echocardiographic findings. To document the Doppler echocardiographic characteristics of midventricular obstruction in some cats with HCM. Eight cats with hypertrophic cardiomyopathy. Retrospective case series. The medical records of cats presenting to the cardiology service at Colorado State University between February 2009 and January 2012 were reviewed. All cats had a physical examination; Doppler systolic blood pressure measurement; and transthoracic two-dimensional (2D), M-mode, and Doppler echocardiography were performed. A more thorough evaluation of the echocardiographic images and measurements was performed. Cats included in this study had echocardiograms of adequate quality to confirm the diagnosis of midventricular obstruction by documentation of left midventricular concentric hypertrophy; a midventricular turbulent Doppler color flow pattern; and high velocity, late-peaking flow at the area of turbulence. Cats with evidence of systemic hypertension defined as a systolic Doppler blood pressure of greater than 170 mmHg were excluded. All 8 cats had left ventricular hypertrophy at the level of the papillary muscles; left, midventricular hypertrophy; and in 4/8 cats there was apical hypertrophy or basilar hypertrophy of the interventricular septum. Color flow Doppler revealed turbulent flow in 8/8 cats and spectral Doppler (continuous and pulsed wave) revealed increased flow velocities and late-peaking flow profiles at the level of the left midventricle. Two of 8 cats had a bifid midventricular flow profile in which there was a midsystolic decline in left ventricular velocities with elevated velocities extending into early diastole. The peak left ventricular outflow velocity in all 8 cats was normal. A variant of HCM characterized by hypertrophy at the level of the papillary muscles with midventricular obstruction is present in some cats. Recognition of this variant of feline HCM allows identification of HCM in cats with murmurs where the more classic features of HCM are not present. Copyright © 2013 by the American College of Veterinary Internal Medicine.
Sack, Kevin L; Dabiri, Yaghoub; Franz, Thomas; Solomon, Scott D; Burkhoff, Daniel; Guccione, Julius M
2018-01-01
Predictive computation models offer the potential to uncover the mechanisms of treatments whose actions cannot be easily determined by experimental or imaging techniques. This is particularly relevant for investigating left ventricular mechanical assistance, a therapy for end-stage heart failure, which is increasingly used as more than just a bridge-to-transplant therapy. The high incidence of right ventricular failure following left ventricular assistance reflects an undesired consequence of treatment, which has been hypothesized to be related to the mechanical interdependence between the two ventricles. To investigate the implication of this interdependence specifically in the setting of left ventricular assistance device (LVAD) support, we introduce a patient-specific finite-element model of dilated chronic heart failure. The model geometry and material parameters were calibrated using patient-specific clinical data, producing a mechanical surrogate of the failing in vivo heart that models its dynamic strain and stress throughout the cardiac cycle. The model of the heart was coupled to lumped-parameter circulatory systems to simulate realistic ventricular loading conditions. Finally, the impact of ventricular assistance was investigated by incorporating a pump with pressure-flow characteristics of an LVAD (HeartMate II™ operating between 8 and 12 k RPM) in parallel to the left ventricle. This allowed us to investigate the mechanical impact of acute left ventricular assistance at multiple operating-speeds on right ventricular mechanics and septal wall motion. Our findings show that left ventricular assistance reduces myofiber stress in the left ventricle and, to a lesser extent, right ventricle free wall, while increasing leftward septal-shift with increased operating-speeds. These effects were achieved with secondary, potentially negative effects on the interventricular septum which showed that support from LVADs, introduces unnatural bending of the septum and with it, increased localized stress regions. Left ventricular assistance unloads the left ventricle significantly and shifts the right ventricular pressure-volume-loop toward larger volumes and higher pressures; a consequence of left-to-right ventricular interactions and a leftward septal shift. The methods and results described in the present study are a meaningful advancement of computational efforts to investigate heart-failure therapies in silico and illustrate the potential of computational models to aid understanding of complex mechanical and hemodynamic effects of new therapies.
Left ventricular structural and functional characteristics in Cushing's syndrome.
Muiesan, Maria Lorenza; Lupia, Mario; Salvetti, Massimo; Grigoletto, Consuelo; Sonino, Nicoletta; Boscaro, Marco; Rosei, Enrico Agabiti; Mantero, Franco; Fallo, Francesco
2003-06-18
This study was designed to evaluate left ventricular (LV) anatomy and function in patients with Cushing's syndrome. A high prevalence of LV hypertrophy and concentric remodeling has been reported in Cushing's syndrome, although no data have been reported on LV systolic and diastolic function. Forty-two consecutive patients with Cushing's syndrome and 42 control subjects, matched for age, gender, and blood pressure, were studied. Left ventricular mass index (LVMI) and relative wall thickness (RWT) were measured by echocardiography, endocardial and midwall fractional shortening (FS) were assessed, and diastolic filling was measured by Doppler transmitral flow. The RWT was significantly greater in Cushing patients than in controls. Left ventricular hypertrophy and concentric remodeling were observed in 10 and 26 patients with Cushing's syndrome, respectively. In Cushing patients, midwall FS was significantly reduced compared with controls (16.2 +/- 3% vs. 21 +/- 4.5%, p = 0.01). The ratio of transmitral E and A flow velocities was reduced and E deceleration time was prolonged in Cushing patients compared with controls (p = 0.03 and p < 0.001, respectively). In patients with Cushing's syndrome, cardiac structural changes are associated with reduced midwall systolic performance and with diastolic dysfunction that may contribute to the high risk of cardiovascular events observed in these patients.
Zhang, Qi; Gao, Bin; Chang, Yu
2017-02-27
BACKGROUND Partial support, as a novel support mode, has been widely applied in clinical practice and widely studied. However, the precise mechanism of partial support of LVAD in the intra-ventricular flow pattern is unclear. MATERIAL AND METHODS In this study, a patient-specific left ventricular geometric model was reconstructed based on CT data. The intra-ventricular flow pattern under 3 simulated conditions - "heart failure", "partial support", and "full support" - were simulated by using fluid-structure interaction (FSI). The blood flow pattern, wall shear stress (WSS), time-average wall shear stress (TAWSS), oscillatory shear index (OSI), and relative residence time (RRT) were calculated to evaluate the hemodynamic effects. RESULTS The results demonstrate that the intra-ventricular flow pattern is significantly changed by the support level of BJUT-II VAD. The intra-ventricular vortex was enhanced under partial support and was eliminated under full support, and the high OSI and RRT regions changed from the septum wall to the cardiac apex. CONCLUSIONS In brief, the support level of the BJUT-II VAD has significant effects on the intra-ventricular flow pattern. The partial support mode of BJUT-II VAD can enhance the intra-ventricular vortex, while the distribution of high OSI and RRT moved from the septum wall to the cardiac apex. Hence, the partial support mode of BJUT-II VAD can provide more benefit for intra-ventricular flow pattern.
Gehlen, H; Kroker, K; Deegen, E; Stadler, P
2004-03-01
30 warmblood horses were examined before and after sedation with 20 micrograms/kg BW detomidine, to determine changes of cardiac function parameters, using B-mode, M-mode and Doppler echocardiography. 15 horses showed a heart murmur, but no clinical signs of cardiac heart failure, 15 horses had neither a heart murmur nor other signs of cardiac disease. After sedation with detomidine we could recognise a significant increase of end-diastolic left atrium diameter, an increase of end-systolic left ventricular diameter and aortic root diameter. The end-systolic thickness of papillary muscle and interventricular septum showed a decrease. Fractional shortening and amplitude of left ventricular wall motion was decreased after sedation. The mitral valve echogram revealed a presystolic valve closure and an inflection in the Ac slope (B-notch) in xy horses before sedation. Both increased after sedation with detomidine. Doppler echocardiography showed a decrease of blood flow velocity and velocity time integral (VTI) in the left and right ventricular outflow tract after sedation. Regurgitant flow signals were intensified following sedation in xy horses, especially at the mitral valve.
Malinowski, Marcin; Wilton, Penny; Khaghani, Asghar; Brown, Michael; Langholz, David; Hooker, Victoria; Eberhart, Lenora; Hooker, Robert L; Timek, Tomasz A
2016-09-01
Left ventricular assist device (LVAD) implantation may alter right ventricular shape and function and lead to tricuspid regurgitation. This in turn has been reported to be a determinant of right ventricular (RV) failure after LVAD implantation, but the effect of mechanical left ventricular (LV) unloading on the tricuspid annulus is unknown. The aim of the study was to provide insight into the effect of LVAD support on tricuspid annular geometry and dynamics that may help to optimize LV unloading with the least deleterious effect on the right-sided geometry. In seven open-chest anaesthetized sheep, nine sonomicrometry crystals were implanted on the right ventricle. Additional nine crystals were implanted around the tricuspid annulus, with one crystal at each commissure defining three separate annular regions: anterior, posterior and septal. Left ventricular unloading was achieved by connecting a cannula in the left atrium and the aorta to a continuous-flow pump. The pump was used for 15 min at a full flow of 3.8 ± 0.3 l/min. Epicardial echocardiography was used to assess the degree of tricuspid insufficiency. Haemodynamic, echocardiographic and sonomicrometry data were collected before and during full unloading. Tricuspid annular area, and the regional and total perimeter were calculated from crystal coordinates, while 3D annular geometry was expressed as the orthogonal distance of each annular crystal to the least squares plane of all annular crystals. There was no significant tricuspid regurgitation observed either before or during LV unloading. Right ventricular free wall to septum diameter increased significantly at end-diastole during unloading from 23.6 ± 5.8 to 26.3 ± 6.5 mm (P = 0.009), but the right ventricular volume, tricuspid annular area and total perimeter did not change from baseline. However, the septal part of the annulus significantly decreased its maximal length (38.6 ± 8.1 to 37.9 ± 8.2 mm, P = 0.03). Annular contraction was not altered. The tricuspid annulus had a complex 3D saddle-shaped geometry that was unaffected during experimental conditions. In healthy sheep hearts, left ventricular unloading increased septal-free wall RV diameter and reduced the length of the septal annulus, without altering the motion or geometry of the tricuspid annulus. Acute left ventricular unloading alone in healthy sheep was not sufficient to significantly perturb tricuspid annular dynamics and result in tricuspid insufficiency. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Left ventricular hypertrophy diagnosed after a stroke: a case report.
Umeojiako, Wilfred Ifeanyi; Kanyal, Ritesh
2018-03-22
Stroke is a recognized clinical course of hypertrophic cardiomyopathy. This interesting case showed notable difference on the electrocardiogram of a patient 4 months prior to suffering a stroke and 10 days after suffering a stroke. The pre-stroke electrocardiogram showed atrial fibrillation with a narrow QRS complex, while the post-stroke electrocardiogram showed marked left ventricular hypertrophy. Left ventricular hypertrophy was diagnosed using the Sokolow-Lyon indices. The development of left ventricular hypertrophy a few days after suffering a stroke has not previously been reported. An 83-year-old white British woman with a background history of permanent atrial fibrillation, hypertension, and previous stroke attended the emergency department with a 2-day history of exertional dyspnea, and chest tightness. On examination, she had bibasal crepitations with a systolic murmur loudest at the apex. In-patient investigations include an electrocardiogram, blood tests, chest X-ray, contrast echocardiogram, coronary angiogram, and cardiovascular magnetic resonance imaging. An electrocardiogram showed atrial fibrillation, with inferolateral T wave inversion, and left ventricular hypertrophy. A chest X-ray showed features consistent with pulmonary edema. A contrast echocardiogram showed marked hypertrophy of the mid to apical left ventricle, appearance consistent with apical hypertrophic cardiomyopathy. Coronary angiography showed eccentric shelf-type plaque with non-flow-limiting stenosis in the left coronary artery main stem. Cardiovascular magnetic resonance imaging reported findings highly suggestive of apical hypertrophic cardiomyopathy. Our patient was treated and discharged on rivaroxaban, bisoprolol, and atorvastatin with a follow-up in the cardiomyopathy outpatient clinic. Electrocardiogram diagnosis of left ventricular hypertrophy led to the diagnosis of apical hypertrophic cardiomyopathy in this patient. Left ventricular hypertrophy was only evident a few days after our patient suffered a stroke. The underlying mechanisms responsible for this remain unclear. Furthermore, differential diagnosis of hypertrophic cardiomyopathy should be considered in people with electrocardiogram criteria for left ventricular hypertrophy. Cardiovascular magnetic resonance imaging is an important diagnostic tool in identifying causes of left ventricular hypertrophy. Family screening should be recommended in patients with new diagnosis of hypertrophic cardiomyopathy.
Regional myocardial shape and dimensions of the working isolated canine left ventricle
NASA Technical Reports Server (NTRS)
Ritman, E.; Tsuiki, K.; Donald, D.; Wood, E. H.
1975-01-01
Angiographic experiments were performed on isolated canine left ventricle preparations using donor dog to supply blood to the coronary circulation via a rotary pump to control coronary flow. The angiographic record was transferred from video tape to video disk for detailed uninterrupted sequential analysis at a frequency of 60 fields/sec. It is shown that the use of a biplane X-ray technique and a metabolically supported isolated canine left ventricle preparation provides an angiographically ideal means of measuring the mechanical dynamics of the myocardium while the intact left ventricular myocardial structure and electrical activation pattern retain most of the in situ ventricular characteristics. In particular, biplane X-ray angiography of the left ventricle can provide estimates of total ventricular function such as ejection fraction, stroke volume, and myocardial mass correct to within 15% under the angiographically ideal conditions of the preparation.
Baranowski, Jacek; Delshad, Baz; Ahn, Henrik
2017-01-01
After implantation of a continuous-flow left ventricular assist device (LVAD), left atrial pressure (LAP) monitoring allows for the precise management of intravascular volume, inotropic therapy, and pump speed. In this case series of 4 LVAD recipients, we report the first clinical use of this wireless pressure sensor for the long-term monitoring of LAP during LVAD support. A wireless microelectromechanical system pressure sensor (Titan, ISS Inc., Ypsilanti, MI) was placed in the left atrium in four patients at the time of LVAD implantation. Titan sensor LAP was measured in all four patients on the intensive care unit and in three patients at home. Ramped speed tests were performed using LAP and echocardiography in three patients. The left ventricular end-diastolic diameter (cm), flow (L/min), power consumption (W), and blood pressure (mm Hg) were measured at each step. Measurements were performed over 36, 84, 137, and 180 days, respectively. The three discharged patients had equipment at home and were able to perform daily recordings. There were significant correlations between sensor pressure and pump speed, LV and LA size and pulmonary capillary wedge pressure, respectively (r = 0.92–0.99, p < 0.05). There was no device failure, and there were no adverse consequences of its use. PMID:27676410
Aortic Wave Dynamics and Its Influence on Left Ventricular Workload
Pahlevan, Niema M.; Gharib, Morteza
2011-01-01
The pumping mechanism of the heart is pulsatile, so the heart generates pulsatile flow that enters into the compliant aorta in the form of pressure and flow waves. We hypothesized that there exists a specific heart rate at which the external left ventricular (LV) power is minimized. To test this hypothesis, we used a computational model to explore the effects of heart rate (HR) and aortic rigidity on left ventricular (LV) power requirement. While both mean and pulsatile parts of the pressure play an important role in LV power requirement elevation, at higher rigidities the effect of pulsatility becomes more dominant. For any given aortic rigidity, there exists an optimum HR that minimizes the LV power requirement at a given cardiac output. The optimum HR shifts to higher values as the aorta becomes more rigid. To conclude, there is an optimum condition for aortic waves that minimizes the LV pulsatile load and consequently the total LV workload. PMID:21853075
Kuznetsova, Tatiana; Cauwenberghs, Nicholas; Knez, Judita; Thijs, Lutgarde; Liu, Yan-Ping; Gu, Yu-Mei; Staessen, Jan A
2015-04-01
The cardio-renal interaction occurs via hemodynamic and humoral factors. Noninvasive assessment of renal hemodynamics is currently possible by assessment of renal resistive index (RRI) derived from intrarenal Doppler arterial waveforms as ((peak systolic velocity - end-diastolic velocity)/peak systolic velocity). Limited information is available regarding the relationship between RRI and cardiac hemodynamics. We investigated these associations in randomly recruited subjects from a general population. In 171 participants (48.5% women; mean age, 52.2 years), using pulsed wave Doppler, we measured RRI (mean, 0.60) and left ventricular outflow tract (LVOT) and transmitral (E and A) blood flow peak velocities and its velocity time integrals (VTI). Using carotid applanation tonometry, we measured central pulse pressure and arterial stiffness indexes such as augmentation pressure and carotid-femoral pulse wave velocity. In stepwise regression analysis, RRI independently and significantly increased with female sex, age, body weight, brachial pulse pressure, and use of β-blockers, whereas it decreased with body height and mean arterial pressure. In multivariable-adjusted models with central pulse pressure and arterial stiffness indexes as the explanatory variables, we observed a significant and positive correlation of RRI only with central pulse pressure (P < 0.0001). Among the Doppler indexes of left ventricular blood flow, RRI was significantly and positively associated with LVOT and E peak velocities (P ≤ 0.012) and VTIs (P ≤ 0.010). We demonstrated that in unselected subjects RRI was significantly associated with central pulse pressure and left ventricular systolic and diastolic Doppler blood flow indexes. Our findings imply that in addition to the anthropometric characteristics, cardiac hemodynamic factors influence the intrarenal arterial Doppler waveform patterns. © American Journal of Hypertension, Ltd 2014. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Jeong, Daniel; Anagnostopoulos, Petros V; Roldan-Alzate, Alejandro; Srinivasan, Shardha; Schiebler, Mark L; Wieben, Oliver; François, Christopher J
2015-05-01
Ventricular kinetic energy measurements may provide a novel imaging biomarker of declining ventricular efficiency in patients with repaired tetralogy of Fallot. Our purpose was to assess differences in ventricular kinetic energy with 4-dimensional flow magnetic resonance imaging between patients with repaired tetralogy of Fallot and healthy volunteers. Cardiac magnetic resonance, including 4-dimensional flow magnetic resonance imaging, was performed at rest in 10 subjects with repaired tetralogy of Fallot and 9 healthy volunteers using clinical 1.5T and 3T magnetic resonance imaging scanners. Right and left ventricular kinetic energy (KERV and KELV), main pulmonary artery flow (QMPA), and aortic flow (QAO) were quantified using 4-dimensional flow magnetic resonance imaging data. Right and left ventricular size and function were measured using standard cardiac magnetic resonance techniques. Differences in peak systolic KERV and KELV in addition to the QMPA/KERV and QAO/KELV ratios between groups were assessed. Kinetic energy indices were compared with conventional cardiac magnetic resonance parameters. Peak systolic KERV and KELV were higher in patients with repaired tetralogy of Fallot (6.06 ± 2.27 mJ and 3.55 ± 2.12 mJ, respectively) than in healthy volunteers (5.47 ± 2.52 mJ and 2.48 ± 0.75 mJ, respectively), but were not statistically significant (P = .65 and P = .47, respectively). The QMPA/KERV and QAO/KELV ratios were lower in patients with repaired tetralogy of Fallot (7.53 ± 5.37 mL/[cycle mJ] and 9.65 ± 6.61 mL/[cycle mJ], respectively) than in healthy volunteers (19.33 ± 18.52 mL/[cycle mJ] and 35.98 ± 7.66 mL/[cycle mJ], respectively; P < .05). QMPA/KERV and QAO/KELV were weakly correlated to ventricular size and function. Greater ventricular kinetic energy is necessary to generate flow in the pulmonary and aortic circulations in repaired tetralogy of Fallot. Quantification of ventricular kinetic energy in patients with repaired tetralogy of Fallot is a new observation. Future studies are needed to determine whether changes in ventricular kinetic energy can provide earlier evidence of ventricular dysfunction and guide future medical and surgical interventions. Copyright © 2015 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Gulel, Okan; Akcay, Murat; Soylu, Korhan; Aksan, Gokhan; Yuksel, Serkan; Zengin, Halit; Meric, Murat; Sahin, Mahmut
2016-05-01
The coronary slow flow phenomenon (CSFP) is defined as a delayed distal vessel contrast opacification in the absence of obstructive epicardial coronary artery disease during coronary angiography. There is conflicting data in medical literature regarding the effects of CSFP on the left ventricular functions assessed by conventional echocardiography or tissue Doppler imaging. Therefore, we aimed to evaluate whether there is any abnormality in the myocardial deformation parameters (strain, strain rate (SR), rotation, twist) of the left ventricle obtained by speckle tracking echocardiography (STE) in patients with CSFP. Twenty patients with CSFP were included prospectively in the study. Another 20 patients with similar demographics and cardiovascular risk factors as well as normal coronary angiography were used as the control group. Two-dimensional echocardiographic images of the left ventricle from the apical long-axis, two-chamber, four-chamber, and parasternal short-axis views were used for STE analysis. The analysis of left ventricular circumferential deformation parameters showed that the averaged peak systolic strain, systolic SR, and early diastolic SR values were significantly lower in patients with CSFP (P = 0.009, P = 0.02, and P = 0.02, respectively). Among the left ventricular rotation and twist values, apical rotation was significantly lower in patients with CSFP (P = 0.02). Further, the mean thrombolysis in myocardial infarction frame count value was found to be negatively correlated with the averaged peak circumferential early diastolic SR (r = -0.35, P = 0.03). It was positively correlated with the averaged peak circumferential systolic strain (r = 0.47, P = 0.003) and circumferential systolic SR (r = 0.46, P = 0.005). Coronary slow flow phenomenon leads to significant alterations in the myocardial deformation parameters of the left ventricle as assessed by STE. Specifically, circumferential deformation parameters are affected in CSFP patients. © 2015, Wiley Periodicals, Inc.
Mynard, Jonathan P; Smolich, Joseph J
2016-07-01
Coronary hemodynamics are known to be affected by intravascular and extravascular factors that vary regionally and transmurally between the perfusion territories of left and right coronary arteries. However, despite clinical evidence that left coronary arterial dominance portends greater cardiovascular risk, relatively little is known about the effects of left or right dominance on regional conduit arterial and microcirculatory blood flow patterns, particularly in the presence of systemic or pulmonary hypertension. We addressed this issue using a multiscale numerical model of the human coronary circulation situated in a closed-loop cardiovascular model. The coronary model represented left or right dominant anatomies and accounted for transmural and regional differences in vascular properties and extravascular compression. Regional coronary flow dynamics of the two anatomical variants were compared under normotensive conditions, raised systemic or pulmonary pressures with maintained flow demand, and after accounting for adaptations known to occur in acute and chronic hypertensive states. Key findings were that 1) right coronary arterial flow patterns were strongly influenced by dominance and systemic/pulmonary hypertension; 2) dominance had minor effects on left coronary arterial and all microvascular flow patterns (aside from mean circumflex flow); 3) although systemic hypertension favorably increased perfusion pressure, this benefit varied regionally and transmurally and was offset by increased left ventricular and septal flow demands; and 4) pulmonary hypertension had a substantial negative effect on right ventricular and septal flows, which was exacerbated by greater metabolic demands. These findings highlight the importance of interactions between coronary arterial dominance and hypertension in modulating coronary hemodynamics. Copyright © 2016 the American Physiological Society.
Ndrepepa, Gjin; Kastrati, Adnan; Schwaiger, Markus; Mehilli, Julinda; Markwardt, Christina; Dibra, Alban; Dirschinger, Josef; Schömig, Albert
2005-11-01
In patients with acute myocardial infarction (AMI) before primary coronary stenting with adjunct glycoprotein IIb/IIIa receptor blockade, whether residual blood flow in the infarct-related artery (IRA) affects infarct size or myocardial salvage is not known. This study included 118 patients with ST-segment elevation AMI who received coronary stenting plus abciximab. SPECT studies were performed before and 7-14 d after stenting. Patients were divided into a group with initial Thrombolysis in Myocardial Infarction (TIMI) flow grade < or = 1 (77 patients) and a group with initial TIMI flow grade > 1 (41 patients). The initial median perfusion defect and (in brackets) the 25th and 75th percentiles were 29.1% [21.0%; 52.0%] of the left ventricle in patients with TIMI flow grade < or = 1, versus 16.5% [8.0%; 33.1%] of the left ventricle in patients with TIMI flow grade > 1 (P < 0.001). Baseline left ventricular ejection fraction (54.0% [45.0; 63.0] vs. 57.0% [40.0; 62.0], P = 0.623) or extension of hypokinetic region (28.0 [14.0; 41.0] hypokinetic chords vs. 24.0 [13.0; 39.0] hypokinetic chords, P = 0.643) did not differ significantly between the group with TIMI flow grade < or = 1 and the group with TIMI flow grade > 1. Final infarct size was 11.0% [6.1%; 23.5%] of the left ventricle in the group with TIMI flow grade < = 1, versus 6.0% [2.0%; 12.8%] of the left ventricle in the group with TIMI flow > 1 (P = 0.008). Salvage index was 0.58 [0.38; 0.76] in the group with TIMI flow grade < or = 1, versus 0.61 [0.36; 0.74] in the group with TIMI flow grade > 1 (P = 0.952). At the day 14 angiography, patients with TIMI flow grade > 1 had better left ventricular ejection fraction (61.0% [54.0%; 68.0%] vs. 56.5% [42.9%; 65.0%]; P = 0.03) and a smaller hypokinetic region (7 chords [0; 22.0] vs. 16 chords [2.5; 30.0]; P = 0.024) than did patients with TIMI flow grade < or = 1. Preserved blood flow in the IRA in patients with AMI is associated with a smaller area at risk, a smaller infarct, and better recovery of regional and global left ventricular function. The proportion of initial area at risk salvaged by coronary stenting does not seem to depend on residual blood flow in the IRA.
Grosman-Rimon, Liza; Billia, Filio; Fuks, Avi; Jacobs, Ira; A McDonald, Michael; Cherney, David Z; Rao, Vivek
2016-07-15
Surgically implanted continuous flow left ventricular assist devices (CF-LVADs) are currently used in patients with end-stage heart failure (HF). However, CF-LVAD therapy introduces a new set of complications and adverse events in these patients. Major adverse events with the CF-LVAD include right heart failure, vascular dysfunction, stroke, hepatic failure, and multi-organ failure, complications that may have inflammation as a common etiology. Our aim was to review the current evidence showing a relationship between these adverse events and elevated levels of inflammatory biomarkers in CF-LVAD recipients. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Myocardial oxygen delivery after experimental hemorrhagic shock.
Archie, J P; Mertz, W R
1978-01-01
The two components of myocardial oxygen delivery, coronary blood flow to capillaries and diffusion from capillaries to mitochondria, were studied in six dogs, (1) prior to shock, (2) after three hours of hemorrhage shock at a mean systemic arterial pressure of 40 torr, (3) after reinfusion of shed blood, and (4) during the irreversible late posttransfusion stage. There was a maldistribution of left ventricular coronary flow during late shock consistent with subendocardial ischemia. Cardiac performance was significantly impaired after resuscitation and all dogs became irreversible. Total and regional left ventricular coronary blood flow and myocardial oxygen delivery to capillaries were significantly greater than preshock values in (3) but not different from preshock values in (4). However, the myocardial oxygen diffusion area to distance ratio was significantly lower than preshock values in (3), and slightly lower in (4). These data suggest that myocardial oxygen diffusion may be impaired in the early post transfusion period, (3). Accordingly, the probable etiology of left ventricular dysfunction and possibly irreversibility after resuscitation from hemorrhagic shock is subendocardial ischemia during shock with either post-resuscitation impairment of myocardial oxygen diffusion, or in cellular oxygen utilization, or both. PMID:629622
Vaujois, Laurence; Boucoiran, Isabelle; Preuss, Christophe; Brassard, Myriam; Houde, Christine; Fouron, Jean C; Raboisson, Marie-Josée
2017-09-01
The relationship between interatrial communication, ductus arteriosus, and pulmonary flow in transposition of the great arteries and intact ventricular septum may help predict postnatal desaturation. Echocardiographic data of 45 fetuses with transposition of the great arteries and intact ventricular septum and 50 age-matched controls were retrospectively reviewed. Interatrial communication, left and right ventricular output, flow in the ductus arteriosus, as well as effective pulmonary flow were measured. Patients were divided into two groups on the basis of postnatal saturations: group 1 had saturations ⩽50% and group 2 >50%. Of 45 fetuses, 13 (26.7%) were classified into group 1. Compared with fetuses in group 2, they had a smaller interatrial communication (2.9 versus 4.0 mm, p=0.004) and more retrograde diastolic flow in the ductus arteriosus (92 versus 23%, p=0.002). Both groups showed a significant decrease in ductal flow compared with controls. Patients in group 2 had a higher effective pulmonary flow compared with controls. There was a mild correlation between left ventricular output and size of the interatrial communication (Spearman's rank correlation 0.44). A retrograde diastolic flow is present in most of the fetuses with postnatal desaturation. Fetuses with transposition of the great arteries have a lower flow through the ductus arteriosus compared with controls. Fetuses without restrictive foramen ovale have higher effective pulmonary flow. Peripheral pulmonary vasodilatation due to higher oxygen saturation in pulmonary arteries in the case of transposition of the great arteries could be one possible cause.
Bedzra, Edo K S; Dardas, Todd F; Cheng, Richard K; Pal, Jay D; Mahr, Claudius; Smith, Jason W; Shively, Kent; Masri, S Carolina; Levy, Wayne C; Mokadam, Nahush A
2017-12-01
To investigate the effect of pulmonary function testing on outcomes after continuous flow left ventricular assist device implantation. A total of 263 and 239 patients, respectively, had tests of forced expiratory volume in 1 second and diffusing capacity of the lungs for carbon monoxide preoperatively for left ventricular assist device implantations between July 2005 and September 2015. Kaplan-Meier analysis and multivariable Cox regressions were performed to evaluate mortality. Patients were analyzed in a single cohort and across 5 groups. Postoperative intensive care unit and hospital lengths of stay were evaluated with negative binomial regressions. There is no association of forced expiratory volume in 1 second and diffusing capacity of the lungs for carbon monoxide with survival and no difference in mortality at 1 and 3 years between the groups (log rank P = .841 and .713, respectively). Greater values in either parameter were associated with decreased hospital lengths of stay. Only diffusing capacity of the lungs for carbon monoxide was associated with increased intensive care unit length of stay in the group analysis (P = .001). Ventilator times, postoperative pneumonia, reintubation, and tracheostomy rates were similar across the groups. Forced expiratory volume in 1 second and diffusing capacity of the lungs for carbon monoxide are not associated with operative or long-term mortality in patients undergoing continuous flow left ventricular assist device implantation. These findings suggest that these abnormal pulmonary function tests alone should not preclude mechanical circulatory support candidacy. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
2001-12-01
instrumented with a high fidelity, dual-sensor micromanometer to measure left ventricular and aortic pressure and a transit-time ultrasound probe to...isoflurane in 100% oxy- gen) prior to insertion of the high -fidelity pressure micromanome- ters during cardiac fluoroscopy. Once the micromanometer trans...and allowed to fully recover from the isoflurane seda- tion for a period of 60 min, during which blood pressure and aortic flow were monitored to ensure
Topilsky, Yan; Maltais, Simon; Oh, Jae K; Atchison, Fawn W; Perrault, Louis P; Carrier, Michel; Park, Soon J
2011-02-08
Left ventricular assist devices (LVADs) are systems for mechanical support for patients with end-stage heart failure. Preoperative, postoperative and comprehensive followup with transthoracic echocardiography has a major role in LVAD patient management. In this paper, we will present briefly the hemodynamics of axial-flow LVAD, the rationale, and available data for a complete and organized echocardiographic assessment in these patients including preoperative assessment, postoperative and long-term evaluation.
Obel, O A; Luddington, L; Maarouf, N; Aytemir, K; Ekwall, C; Malik, M; Camm, A J
2005-01-01
Objective: To prospectively determine whether ventricular rate and regularity are significant determinants of the velocity and magnitude of left atrial appendage (LAA) flow. Design and patients: 12 patients with atrial fibrillation (AF), high degree atrioventricular block, and indwelling permanent pacemakers were studied. Setting: Cardiology department of a tertiary referral centre. Interventions: Pacing was triggered by an external programmable transcutaneous device. Patients were paced at 60, 120, and 150 beats/min in both regular and irregular rhythm. LAA flow velocity and magnitude were assessed with transoesophageal Doppler echocardiography. Main outcome measures: Peak and mean LAA inflow and outflow velocity, and time-velocity interval (TVI) of LAA flow. Results: Increasing ventricular rate was associated with significantly lower peak inflow (p < 0.01), peak outflow (p < 0.05), mean inflow (p < 0.01), and mean outflow (p < 0.05) velocities and with a lower TVI of LAA filling and emptying velocities (p < 0.01). This effect was noted at rates of 60 beats/min compared with both 120 and 150 beats/min. At a pacing rate of 120 beats/min there was a significantly higher total TVI when pacing at a regular than at an irregular rhythm (40.16 (14.6) cm v 30.74 (10.9) cm, p < 0.05). Conclusions: In this study, LAA filling velocities in patients in AF were significantly influenced by paced ventricular rate and to a much lesser extent ventricular rhythm. These results suggest that rapid ventricular rates may predispose to stasis in the LAA in AF. PMID:15894771
Bouwmeester, J Christopher; Park, Jiheum; Valdovinos, John; Bonde, Pramod
2018-05-29
Changing the speed of left ventricular assist devices (LVADs) cyclically may be useful to restore aortic pulsatility; however, the effects of this pulsation on right ventricular (RV) function are unknown. This study investigates the effects of direct ventricular interaction by quantifying the amount of wave energy created by RV contraction when axial and centrifugal LVADs are used to assist the left ventricle. In 4 anesthetized pigs, pressure and flow were measured in the main pulmonary artery and wave intensity analysis was used to identify and quantify the energy of waves created by the RV. The axial pump depressed the intensity of waves created by RV contraction compared with the centrifugal pump. In both pump designs, there were only minor and variable differences between the continuous and pulsed operation on RV function. The axial pump causes the RV to contract with less energy compared with a centrifugal design. Diminishing the ability of the RV to produce less energy translates to less pressure and flow produced, which may lead to LVAD-induced RV failure. The effects of pulsed LVAD operation on the RV appear to be minimal during acute observation of healthy hearts. Further study is necessary to uncover the effects of other modes of speed modulation with healthy and unhealthy hearts to determine if pulsed operation will benefit patients by reducing LVAD complications.
Iseler, Jackeline; Fox, John; Wierenga, Kelly
2018-06-01
The 30-day readmission rate for patients with a left ventricular assist device implantation at a large, urban, Midwest hospital system (from October 2013 to September 2014) was estimated at 32.1%. Readmission rates were a concern at this facility. Review of the readmissions, change in practice, and home expectations of patients and families have identified an opportunity to improve the transitions of care for this left ventricular assist device (LVAD) program. Therefore, the purpose of this project was to evaluate the effectiveness and feasibility of a transitional care model (TCM) for care of patients with left ventricular devices. Ten patients were enrolled in the pilot that was implemented in June 2015. A transitional care nurse trained to support patients with ventricular assist devices was used to facilitate patient flow. The goal was to create an individualized plan for the development or improvement of self-management skills to decrease readmission rates. The transitional care nurse collaborated with the ventricular device team. The 30-day readmission rate during the pilot was 14.3% compared to the previous annual overall rate of 42.6%. Based on these results, further research is recommended into interventions consistent with the TCM to advance care coordination and to facilitate care transition in the this fragile patient population.
Campbell, K B; Shroff, S G; Kirkpatrick, R D
1991-06-01
Based on the premise that short-time-scale, small-amplitude pressure/volume/outflow behavior of the left ventricular chamber was dominated by dynamic processes originating in cardiac myofilaments, a prototype model was built to predict pressure responses to volume perturbations. In the model, chamber pressure was taken to be the product of the number of generators in a pressure-bearing state and their average volumetric distortion, as in the muscle theory of A.F. Huxley, in which force was equal to the number of attached crossbridges and their average lineal distortion. Further, as in the muscle theory, pressure generators were assumed to cycle between two states, the pressure-bearing state and the non-pressure-bearing state. Experiments were performed in the isolated ferret heart, where variable volume decrements (0.01-0.12 ml) were removed at two commanded flow rates (flow clamps, -7 and -14 ml/sec). Pressure responses to volume removals were analyzed. Although the prototype model accounted for most features of the pressure responses, subtle but systematic discrepancies were observed. The presence or absence of flow and the magnitude of flow affected estimates of model parameters. However, estimates of parameters did not differ when the model was fitted to flow clamps with similar magnitudes of flows but different volume changes. Thus, prototype model inadequacies were attributed to misrepresentations of flow-related effects but not of volume-related effects. Based on these discrepancies, an improved model was built that added to the simple two-state cycling scheme, a pathway to a third state. This path was followed only in response to volume change. The improved model eliminated the deficiencies of the prototype model and was adequate in accounting for all observations. Since the template for the improved model was taken from the cycling crossbridge theory of muscle contraction, it was concluded that, in spite of the complexities of geometry, architecture, and regional heterogeneity of function and structure, crossbridge mechanisms dominated the short-time-scale dynamics of left ventricular chamber behavior.
Time course of pressure and flow in ascending aorta during ejection.
Perlini, S; Soldà, P L; Piepoli, M; Calciati, A; Paro, M; Marchetti, G; Meno, F; Finardi, G; Bernardi, L
1991-02-01
To analyze aortic flow and pressure relationships, 10 closed-chest anaesthetised dogs were instrumented with electromagnetic aortic flow probes and micromanometers in the left ventricle and ascending aorta. Left ventricular ejection time was divided into: time to peak flow (T1) (both pressure and flow rising), peak flow to peak pressure time (T2) (pressure rising, flow decreasing), and peak pressure to dicrotic notch time (T3) (pressure and flow both decreasing). These time intervals were expressed as percent of total ejection time. Load-active interventions rose markedly T2 (from 4.2 +/- 5.5 to 19.4 +/- 3.5 after phenylephrine (p less than 0.02); from 4.2 +/- 6.5 to 21.2 +/- 5.3 after dextran (p less than 0.02)). Conversely, dobutamine reduced T2 from 4.4 +/- 5.9 to -2.5 +/- 6.5 (p less than 0.05). Thus, during load-active interventions aortic pressure increases for a longer T2 time although forward flow is decreasing, as a result of higher aortic elastic recoil during ejection. Conversely, beta 1-adrenergic stimulation significantly shortens T2. Dynamic pressure-flow relationship is thus continuously changing during ejection. T2 seems to be inversely related to the efficiency of left ventricular ejection dynamics.
Continuous-flow cardiac assistance: effects on aortic valve function in a mock loop.
Tuzun, Egemen; Rutten, Marcel; Dat, Marco; van de Vosse, Frans; Kadipasaoglu, Cihan; de Mol, Bas
2011-12-01
As the use of left ventricular assist devices (LVADs) to treat end-stage heart failure has become more widespread, leaflet fusion--with resul-tant aortic regurgitation--has been observed more frequently. To quantitatively assess the effects of nonpulsatile flow on aortic valve function, we tested a continuous-flow LVAD in a mock circulatory system (MCS) with an interposed valve. To mimic the hemodynamic characteristics of LVAD patients, we utilized an MCS in which a Jarvik 2000 LVAD was positioned at the base of a servomotor-operated piston pump (left ventricular chamber). We operated the LVAD at 8000 to 12,000 rpm, changing the speed in 1000-rpm increments. At each speed, we first varied the outflow resistance at a constant stroke volume, then varied the stroke volume at a constant outflow resistance. We measured the left ventricular pressure, aortic pressure, pump flow, and total flow, and used these values to compute the change, if any, in the aortic duty cycle (aortic valve open time) and transvalvular aortic pressure loads. Validation of the MCS was demonstrated by the simulation of physiologic pressure and flow waveforms. At increasing LVAD speeds, the mean aortic pressure load steadily increased, while the aortic duty cycle steadily decreased. Changes were consistent for each MCS experimental setting, despite variations in stroke volume and outflow resistance. Increased LVAD flow results in an impaired aortic valve-open time due to a pressure overload above the aortic valve. Such an overload may initiate structural changes, causing aortic leaflet fusion and/or regurgitation. Copyright © 2011 Elsevier Inc. All rights reserved.
Van Herck, P L; Carlier, S G; Claeys, M J; Haine, S E; Gorissen, P; Miljoen, H; Bosmans, J M; Vrints, C J
2007-10-01
To investigate the underlying mechanisms of a decreased coronary flow reserve after myocardial infarction (MI) by analysing the characteristics of the diastolic hyperaemic coronary pressure-flow relationship. Prospective study. Tertiary care hospital. 68 patients with a recent MI and 27 patients with stable angina pectoris (AP; control group). The intercept with the pressure axis (the zero flow pressure or Pzf) and slope index of the pressure-flow relationship (SIPF) were calculated from the simultaneously recorded hyperaemic intracoronary blood flow velocity and aortic pressure after successful coronary stenting. A stepwise increase in Pzf from AP (14.6 (8.0) mm Hg), over non-Q-wave MI (22.5 (9.1) mm Hg), to Q-wave MI (37.1 (12.9) mm Hg; p<0.001) was observed. Similar changes in Pzf were found in a reference artery perfusing the non-infarcted myocardium. Multivariate analysis showed that in both regions the left ventricular end-diastolic pressure (LVEDP) was the most important determinant of the Pzf. The SIPF was not statistically different in the treated vessel between patients with MI and AP, but was increased in MI patients with a markedly increased LVEDP. After an MI, the coronary pressure-flow relationship is shifted to the right both in the infarcted and in the non-infarcted remote myocardium, as shown by the increased Pzf. The correlation with Pzf suggests that elevated left ventricular filling pressures contribute to the impediment of myocardial perfusion in patients with infarction.
Ghodsizad, Ali; Badiye, A; Zeriouh, M; Pae, W; Koerner, M M; Loebe, M
2016-12-14
Despite advances in pump technology, thromboembolic events and pump thrombosis are potentially life-threatening complications in patients with continuous flow ventricular assist devices. Here we describe a patient with pump thrombosis following LVAD HeartMate II implantation presenting with Aspirin and Plavix resistance and signs of acute hemolysis as manifested by high LDH, changing pump power, pulse index and reduced pump flows.
Ma, Hong; Xie, Rong-Ai; Gao, Li-Jian; Zhang, Jin-Ping; Wu, Wei-Chun; Wang, Hao
2015-10-01
The purpose of this study was to investigate the diagnostic value of 3-dimensional (3D) speckle-tracking echocardiography for estimating left ventricular filling pressure in patients with coronary artery disease (CAD) and a preserved left ventricular ejection fraction. Altogether, 84 patients with CAD and 30 age- and sex-matched healthy control participants in sinus rhythm were recruited prospectively. All participants underwent conventional and 3D speckle-tracking echocardiography. Global strain values were automatically calculated by 3D speckle-tracking analysis. The left ventricular end-diastolic pressure (LVEDP) was determined invasively by left heart catheterization. Echocardiography and cardiac catheterization were performed within 24 hours. Compared with the controls, patients with CAD showed lower global longitudinal strain, global circumferential strain, global area strain, and global radial strain. Patients with CAD who had an elevated LVEDP had much lower levels of all 4 3D-speckle-tracking echocardiographic variables. Pearson correlation analysis revealed that the LVEDP correlated positively with the early transmitral flow velocity/early diastolic myocardial velocity (E/E') ratio, global longitudinal strain, global circumferential strain, and global area strain. It correlated negatively with global radial strain. Receiver operating characteristic curve analysis revealed that these 3D speckle-tracking echocardiographic indices could effectively predict elevated left ventricular filling pressure (LVEDP >15 mm Hg) in patients with CAD (areas under the curve: global longitudinal strain, 0.78; global radial strain, 0.77; global circumferential strain, 0.75; and global area strain, 0.74). These parameters, however, showed no advantages over the commonly used E/E' ratio (area under the curve, 0.84). Three-dimensional speckle-tracking echocardiography was a practical technique for predicting elevated left ventricular filling pressure, but it might not be superior to the commonly used E/E' ratio in patients with CAD who have a normal left ventricular ejection fraction. © 2015 by the American Institute of Ultrasound in Medicine.
NASA Astrophysics Data System (ADS)
Zhao, Enfa; Zhang, Yafei; Kang, Chunmiao; Niu, Hua; Zhao, Jing; Sun, Lei; Liu, Baomin
2017-03-01
The purpose of this study was to investigate the influence of the Valsalva maneuver (VM) on cardiac hemodynamics in patients with patent foramen ovale (PFO). Sixty-five patients who were highly suspected to have PFO were included. The changes in E, A, E/A ratio of mitral valve blood flow, E, A, E/A ratio of tricuspid valve blood flow, left ventricular end-diastolic volume, area and right atrial area during the resting state and the strain phase of the Valsalva maneuver were observed by transthoracic echocardiography (TTE). Statistical analyses were performed using SPSS Version18.0. Compared to the resting state, mitral valve diastolic velocity E and A peaks at the strain phase of the Valsalva maneuver significantly decreased (P < 0.05), left ventricular end diastolic volume(LVEDV) and area(LVEDA) decreased significantly (P < 0.05), while E/A ratio of mitral valve, tricuspid valve systolic velocity E and A peaks and E/A ratio remained unchanged (P > 0.05). PFO hemodynamic changes mainly occurred in the left ventricle when the Valsalva maneuver was performed. The Valsalva maneuver increased pressure in the chest, then pulmonary venous return was impeded, which resulted in left ventricular limited filling, and E and A peaks decreased. The pressure of the left ventricle and atrium was lower than that of the right side, which resulted in right-to-left shunt (RLS) through PFO.
NASA Technical Reports Server (NTRS)
Bauer, Fabrice; Jones, Michael; Shiota, Takahiro; Firstenberg, Michael S.; Qin, Jian Xin; Tsujino, Hiroyuki; Kim, Yong Jin; Sitges, Marta; Cardon, Lisa A.; Zetts, Arthur D.;
2002-01-01
OBJECTIVE: The goal of this study was to analyze left ventricular outflow tract systolic acceleration (LVOT(Acc)) during alterations in left ventricular (LV) contractility and LV filling. BACKGROUND: Most indexes described to quantify LV systolic function, such as LV ejection fraction and cardiac output, are dependent on loading conditions. METHODS: In 18 sheep (4 normal, 6 with aortic regurgitation, and 8 with old myocardial infarction), blood flow velocities through the LVOT were recorded using conventional pulsed Doppler. The LVOT(Acc) was calculated as the aortic peak velocity divided by the time to peak flow; LVOT(Acc) was compared with LV maximal elastance (E(m)) acquired by conductance catheter under different loading conditions, including volume and pressure overload during an acute coronary occlusion (n = 10). In addition, a clinically validated lumped-parameter numerical model of the cardiovascular system was used to support our findings. RESULTS: Left ventricular E(m) and LVOT(Acc) decreased during ischemia (1.67 +/- 0.67 mm Hg.ml(-1) before vs. 0.93 +/- 0.41 mm Hg.ml(-1) during acute coronary occlusion [p < 0.05] and 7.9 +/- 3.1 m.s(-2) before vs. 4.4 +/- 1.0 m.s(-2) during coronary occlusion [p < 0.05], respectively). Left ventricular outflow tract systolic acceleration showed a strong linear correlation with LV E(m) (y = 3.84x + 1.87, r = 0.85, p < 0.001). Similar findings were obtained with the numerical modeling, which demonstrated a strong correlation between predicted and actual LV E(m) (predicted = 0.98 [actual] -0.01, r = 0.86). By analysis of variance, there was no statistically significant difference in LVOT(Acc) under different loading conditions. CONCLUSIONS: For a variety of hemodynamic conditions, LVOT(Acc) was linearly related to the LV contractility index LV E(m) and was independent of loading conditions. These findings were consistent with numerical modeling. Thus, this Doppler index may serve as a good noninvasive index of LV contractility.
Zhou, Bin-Yu; Xie, Ming-Xing; Wang, Jing; Wang, Xin-Fang; Lv, Qing; Liu, Man-Wei; Kong, Shuang-Shuang; Zhang, Ping-Yu; Liu, Jin-Feng
2017-01-01
Abstract Intraventricular hydrodynamics plays an important role in evaluating cardiac function. Relationship between diastolic vortex and left ventricular (LV) filling is still rarely elucidated. The aim of this study was to evaluate the evolution of vortex during diastole in hyperthyroidism (HT) and explore the alteration of hydromechanics characteristics with sensitive indexes. Forty-three patients diagnosed with HT were classified into 2 groups according to whether myocardial damage existed: simple hyperthyroid group (HT1, n = 21) and thyrotoxic cardiomyopathy (HT2, n = 22). Twenty-seven age- and gender-matched healthy volunteers were enrolled as the control group. Offline vector flow mapping (VFM model) was used to analyze the LV diastolic blood flow patterns and fluid dynamics. Hemodynamic parameters, vortex area (A), circulation (C), and intraventricular pressure gradient (ΔP), in different diastolic phases (early, mid, and late) were calculated and analyzed. HT2, with a lower E/A ratio and left ventricular ejection fraction (LVEF), had a larger left atrium diameter (LAD) compared with those of the control group and HT1 (P < .05). Compared with the control group, the vortex size and strength, intraventricular pressure gradient during early and mid-diastole were higher in HT1 and lower in HT2 (P < .05). And in late diastole, the vortex size and strength, intraventricular pressure gradient of HT2 became higher than those of the control group (P < .05). Good correlation could be found between CE and E/A (P < .05), CM and ΔPM (P < .01), CL and FT3 (P < .05). VFM is proven practical for detecting the relationship between the changes of left ventricular diastolic vortex and the abnormal left ventricular filling. PMID:28445281
Zhou, Bin-Yu; Xie, Ming-Xing; Wang, Jing; Wang, Xin-Fang; Lv, Qing; Liu, Man-Wei; Kong, Shuang-Shuang; Zhang, Ping-Yu; Liu, Jin-Feng
2017-04-01
Intraventricular hydrodynamics plays an important role in evaluating cardiac function. Relationship between diastolic vortex and left ventricular (LV) filling is still rarely elucidated. The aim of this study was to evaluate the evolution of vortex during diastole in hyperthyroidism (HT) and explore the alteration of hydromechanics characteristics with sensitive indexes.Forty-three patients diagnosed with HT were classified into 2 groups according to whether myocardial damage existed: simple hyperthyroid group (HT1, n = 21) and thyrotoxic cardiomyopathy (HT2, n = 22). Twenty-seven age- and gender-matched healthy volunteers were enrolled as the control group. Offline vector flow mapping (VFM model) was used to analyze the LV diastolic blood flow patterns and fluid dynamics. Hemodynamic parameters, vortex area (A), circulation (C), and intraventricular pressure gradient (ΔP), in different diastolic phases (early, mid, and late) were calculated and analyzed.HT2, with a lower E/A ratio and left ventricular ejection fraction (LVEF), had a larger left atrium diameter (LAD) compared with those of the control group and HT1 (P < .05). Compared with the control group, the vortex size and strength, intraventricular pressure gradient during early and mid-diastole were higher in HT1 and lower in HT2 (P < .05). And in late diastole, the vortex size and strength, intraventricular pressure gradient of HT2 became higher than those of the control group (P < .05). Good correlation could be found between CE and E/A (P < .05), CM and ΔPM (P < .01), CL and FT3 (P < .05).VFM is proven practical for detecting the relationship between the changes of left ventricular diastolic vortex and the abnormal left ventricular filling.
VENTRICULAR SEPTAL DEFECT IN A CRAB-EATING FOX (CERDOCYON THOUS).
Sousa, Marlos Gonçalves; de Córdova, Fabiano Mendes; Ramos, Adriano Tony; Viana, Eduardo Borges; de Castro Conti, Laura Monteiro
2016-06-01
Congenital heart diseases are not commonly diagnosed in wild animals. It is not surprising that few reports exist in the literature, so that prevalence of these anomalies is unknown in wild species. We report a case of a ventricular septal defect documented in a free-ranging crab-eating fox (Cerdocyon thous). This animal presented with rapid, labored breathing, and on physical examination, pulmonary crackles and a holosystolic murmur were auscultated. The echocardiogram with Doppler showed discontinuity of the dorsal section of the ventricular septum, which allowed a turbulent systolic flow to move from the left to the right ventricle. The postmortem examination confirmed the absence of a dorsal connection between the septum and the atrioventricular junction, and pronounced left ventricular myocardial dilation was observed on histopathology. To the authors' knowledge, this is the first report of a perimembranous ventricular septal defect in a crab-eating fox.
The role of intraventricular vortices in the left ventricular filling?
NASA Astrophysics Data System (ADS)
Martinez-Legazpi, Pablo; Bermejo, Javier; Benito, Yolanda; Alhama, Marta; Yotti, Raquel; Perez Del Villar, Candelas; Gonzalez-Mansilla, Ana; Barrio, Alicia; Fernandez-Aviles, Francisco; Del Alamo, Juan Carlos
2013-11-01
The generation of vortices during early filling is a salient feature of left ventricular hemodynamics. Existing clinical data suggest that these intraventricular vortices may facilitate pulling flow from the left atrium. To test this hypothesis, we have quantitatively dissected the contribution of the vortex to intraventricular pressure gradients by isolating its induced flow in ultrasound-derived data in 20 patients with non-ischemic dilated cardiomyopathy (NIDCM), 20 age-matched healthy controls and 20 patients with hypertrophied cardiomyopathy. We have observed that, in patients with NIDCM, the hemodynamic forces were shown to be partially supported by the flow inertia whereas that effect was minimized in healthy hearts. In patients with hypertrophied cardiomiopathy such effect was not observed. Supported by grants, PIS09/02603, RD06/0010 (RECAVA), CM12/00273 (to CPV) and BA11/00067 (to JB) from the Instituto de Salud Carlos III, Spain. PML and JCA were partially supported by NIH grant 1R21 HL108268-01.
Wang, Yu; Koenig, Steven C; Slaughter, Mark S; Giridharan, Guruprasad A
2015-01-01
The risk for left ventricular (LV) suction during left ventricular assist devices (LVAD) support has been a clinical concern. Current development efforts suggest LVAD suction prevention and physiologic control algorithms may require chronic implantation of pressure or flow sensors, which can be unreliable because of baseline drift and short lifespan. To overcome this limitation, we designed a sensorless suction prevention and physiologic control (eSPPC) algorithm that only requires LVAD intrinsic parameters (pump speed and power). Two gain-scheduled, proportional-integral controllers maintain a differential pump speed (ΔRPM) above a user-defined threshold to prevent LV suction while maintaining an average reference differential pressure (ΔP) between the LV and aorta. ΔRPM is calculated from noisy pump speed measurements that are low-pass filtered, and ΔP is estimated using an extended Kalman filter. Efficacy and robustness of the eSPPC algorithm were evaluated in silico during simulated rest and exercise test conditions for 1) excessive ΔP setpoint (ES); 2) rapid eightfold increase in pulmonary vascular resistance (PVR); and 3) ES and PVR. Simulated hemodynamic waveforms (LV pressure and volume; aortic pressure and flow) using only intrinsic pump parameters showed the feasibility of our proposed eSPPC algorithm in preventing LV suction for all test conditions.
Role of left ventricular twist mechanics in cardiomyopathies, dance of the helices
Kauer, Floris; Geleijnse, Marcel Leonard; van Dalen, Bastiaan Martijn
2015-01-01
Left ventricular twist is an essential part of left ventricular function. Nevertheless, knowledge is limited in “the cardiology community” as it comes to twist mechanics. Fortunately the development of speckle tracking echocardiography, allowing accurate, reproducible and rapid bedside assessment of left ventricular twist, has boosted the interest in this important mechanical aspect of left ventricular deformation. Although the fundamental physiological role of left ventricular twist is undisputable, the clinical relevance of assessment of left ventricular twist in cardiomyopathies still needs to be established. The fact remains; analysis of left ventricular twist mechanics has already provided substantial pathophysiological understanding on a comprehensive variety of cardiomyopathies. It has become clear that increased left ventricular twist in for example hypertrophic cardiomyopathy may be an early sign of subendocardial (microvascular) dysfunction. Furthermore, decreased left ventricular twist may be caused by left ventricular dilatation or an extensive myocardial scar. Finally, the detection of left ventricular rigid body rotation in noncompaction cardiomyopathy may provide an indispensible method to objectively confirm this difficult diagnosis. All this endorses the value of left ventricular twist in the field of cardiomyopathies and may further encourage the implementation of left ventricular twist parameters in the “diagnostic toolbox” for cardiomyopathies. PMID:26322187
Winter, R; Gudmundsson, P; Ericsson, G; Willenheimer, R
2001-06-01
To study the clinical value of the colour-M-mode slope of the early diastolic left ventricular filling phase (Vp) and the early diastolic downward M-mode slope of the left atrioventricular plane displacement (EDS), compared with diastolic function assessed by traditional Doppler evaluation. In 65 consecutive patients EDS and Vp were compared with a four-degree traditional diastolic function classification, based on pulsed Doppler assessment of the early to atrial transmitral flow ratio (E/A), the E-wave deceleration time (Edt), and the systolic to diastolic (S/D) pulmonary venous inflow ratio. Vp (P=0.006) and EDS (P=0.045) were related to traditional diastolic function (Kruskal--Wallis analysis). EDS showed a trend brake between the moderate and severe diastolic dysfunction groups by traditional Doppler evaluation. Vp and EDS correlated weakly in simple linear regression analysis (r=0.33). Vp and EDS discriminated poorly between normal and highly abnormal diastolic function. Vp and EDS were significantly related to diastolic function by traditional Doppler evaluation. They were, however, not useful as single parameters of left ventricular diastolic function due to a small difference between normal and highly abnormal values, allowing for little between-measurement variability. Consequently, these methods for the evaluation of left ventricular diastolic function do not add significantly to traditional Doppler evaluation.
Bartoli, Carlo R.; Koenig, Steven C.; Ionan, Constantine; Gillars, Kevin J.; Mitchell, Mike E.; Austin, Erle H.; Gray, Laman A.; Pantalos, George M.
2014-01-01
OBJECTIVE Despite progress with adult ventricular assist devices (VADs), limited options exist to support pediatric patients with life-threatening heart disease. Extracorporeal membrane oxygenation (ECMO) remains the clinical standard. To characterize (patho)physiologic responses to different modes of mechanical unloading of the failing pediatric heart, ECMO was compared to either intraaortic balloon pump (IABP), pulsatile-flow (PF)VAD, or continuous-flow (CF)VAD support in a pediatric heart failure model. DESIGN Experimental. SETTING Large animal laboratory operating room. SUBJECTS Yorkshire piglets (n=47, 11.7±2.6 kg). INTERVENTIONS In piglets with coronary ligation-induced cardiac dysfunction, mechanical circulatory support devices were implanted and studied during maximum support. MEASUREMENTS and MAIN RESULTS Left ventricular, right ventricular, coronary, carotid, systemic arterial, and pulmonary arterial hemodynamics were measured with pressure and flow transducers. Myocardial oxygen consumption and total-body oxygen consumption (VO2) were calculated from arterial, venous, and coronary sinus blood sampling. Blood flow was measured in 17 organs with microspheres. Paired student t-tests compared baseline and heart failure conditions. One-way repeated-measures ANOVA compared heart failure, device support mode(s), and ECMO. Statistically significant (p<0.05) findings included: 1) improved left ventricular blood supply/demand ratio during PFVAD, CFVAD, and ECMO but not IABP support, 2) improved global myocardial blood supply/demand ratio during PFVAD, and CFVAD but not IABP or ECMO support, and 3) diminished pulsatility during ECMO and CFVAD but not IABP and PFVAD support. A profile of systems-based responses was established for each type of support. CONCLUSIONS Each type of pediatric VAD provided hemodynamic support by unloading the heart with a different mechanism that created a unique profile of physiological changes. These data contribute novel, clinically relevant insight into pediatric mechanical circulatory support and establish an important resource for pediatric device development and patient selection. PMID:24108116
NASA Technical Reports Server (NTRS)
Tsujino, H.; Jones, M.; Shiota, T.; Qin, J. X.; Greenberg, N. L.; Cardon, L. A.; Morehead, A. J.; Zetts, A. D.; Travaglini, A.; Bauer, F.;
2001-01-01
Quantification of flow with pulsed-wave Doppler assumes a "flat" velocity profile in the left ventricular outflow tract (LVOT), which observation refutes. Recent development of real-time, three-dimensional (3-D) color Doppler allows one to obtain an entire cross-sectional velocity distribution of the LVOT, which is not possible using conventional 2-D echo. In an animal experiment, the cross-sectional color Doppler images of the LVOT at peak systole were derived and digitally transferred to a computer to visualize and quantify spatial velocity distributions and peak flow rates. Markedly skewed profiles, with higher velocities toward the septum, were consistently observed. Reference peak flow rates by electromagnetic flow meter correlated well with 3-D peak flow rates (r = 0.94), but with an anticipated underestimation. Real-time 3-D color Doppler echocardiography was capable of determining cross-sectional velocity distributions and peak flow rates, demonstrating the utility of this new method for better understanding and quantifying blood flow phenomena.
Effects of Frequent Hemodialysis on Ventricular Volumes and Left Ventricular Remodeling
Greene, Tom; Chertow, Glenn M.; Kliger, Alan S.; Stokes, John B.; Beck, Gerald J.; Daugirdas, John T.; Kotanko, Peter; Larive, Brett; Levin, Nathan W.; Mehta, Ravindra L.; Rocco, Michael; Sanz, Javier; Yang, Phillip C.; Rajagopalan, Sanjay
2013-01-01
Summary Background and objectives Higher left ventricular volume is associated with death in patients with ESRD. This work investigated the effects of frequent hemodialysis on ventricular volumes and left ventricular remodeling. Design, setting, participants, & measurements The Frequent Hemodialysis Network daily trial randomized 245 patients to 12 months of six times per week versus three times per week in-center hemodialysis; the Frequent Hemodialysis Network nocturnal trial randomized 87 patients to 12 months of six times per week nocturnal hemodialysis versus three times per week predominantly home-based hemodialysis. Left and right ventricular end systolic and diastolic volumes, left ventricular mass, and ejection fraction at baseline and end of the study were ascertained by cardiac magnetic resonance imaging. The ratio of left ventricular mass/left ventricular end diastolic volume was used as a surrogate marker of left ventricular remodeling. In each trial, the effect of frequent dialysis on left or right ventricular end diastolic volume was tested between predefined subgroups. Results In the daily trial, frequent hemodialysis resulted in significant reductions in left ventricular end diastolic volume (−11.0% [95% confidence interval, −16.1% to −5.5%]), left ventricular end systolic volume (−14.8% [−22.7% to −6.2%]), right ventricular end diastolic volume (−11.6% [−19.0% to −3.6%]), and a trend for right ventricular end systolic volume (−11.3% [−21.4% to 0.1%]) compared with conventional therapy. The magnitude of reduction in left and right ventricular end diastolic volumes with frequent hemodialysis was accentuated among patients with residual urine output<100 ml/d (P value [interaction]=0.02). In the nocturnal trial, there were no significant changes in left or right ventricular volumes. The frequent dialysis interventions had no substantial effect on the ratio of left ventricular mass/left ventricular end diastolic volume in either trial. Conclusions Frequent in-center hemodialysis reduces left and right ventricular end systolic and diastolic ventricular volumes as well as left ventricular mass, but it does not affect left ventricular remodeling. PMID:23970131
Hyler, Stefan; Pischke, Søren E; Halvorsen, Per Steinar; Espinoza, Andreas; Bergsland, Jacob; Tønnessen, Tor Inge; Fosse, Erik; Skulstad, Helge
2015-04-01
Sensitive methods for the early detection of myocardial dysfunction are still needed, as ischemia is a leading cause of decreased ventricular function during and after heart surgery. The aim of this study was to test the hypothesis that low-grade ischemia could be detected quantitatively by a miniaturized epicardial ultrasound transducer (Ø = 3 mm), allowing continuous monitoring. In 10 pigs, transducers were positioned in the left anterior descending and circumflex coronary artery areas. Left ventricular pressure was obtained by a micromanometer. The left internal mammary artery was grafted to the left anterior descending coronary artery, which was occluded proximal to the anastomosis. Left internal mammary artery flow was stepwise reduced by 25%, 50%, and 75% for 18 min each. From the transducers, M-mode traces were obtained, allowing continuous tissue velocity traces and displacement measurements. Regional work was assessed as left ventricular pressure-displacement loop area. Tissue lactate measured from intramyocardial microdialysis was used as reference method to detect ischemia. All steps of coronary flow reduction demonstrated reduced peak systolic velocity (P < .05) and regional work (P < .01).The decreases in peak systolic velocity and regional work were closely related to the degree of ischemia, demonstrated by their correlations with lactate (R = -0.74, P < .01, and R = -0.64, P < .01, respectively). The circumflex coronary artery area was not affected by any of the interventions. The epicardially attached miniaturized ultrasound transducer allowed the precise detection of different levels of coronary flow reduction. The results also showed a quantitative and linear relationship among coronary flow, ischemia, and myocardial function. Thus, the ultrasound transducer has the potential to improve the monitoring of myocardial ischemia and to detect graft failure during and after heart surgery. Copyright © 2015 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
Coil occlusion of residual shunts after surgical closure of patent ductus arteriosus.
Fujii, Yoko; Keene, Bruce W; Mathews, Kyle G; Atkins, Clarke E; Defrancesco, Teresa C; Hardie, Elizabeth M; Wakao, Yoshito
2006-12-01
OBJECTIVE; To describe use of coil embolization to occlude residual flow through a patent ductus arteriosus (PDA) after incomplete surgical ligation. Clinical study. Dogs (n=4) with continuous murmur after surgical ligation of PDA. After PDA ligation, residual ductal flow through the PDA was visible on color-flow Doppler examination and left ventricular end-diastolic diameter remained increased. Coil embolization by an arterial approach was performed to achieve complete occlusion of the PDA. Embolization coils were delivered without complications and hemodynamically successful occlusion was achieved. Doppler-visible flow resolved in 2 dogs within 3 months after embolization. Left ventricular end-diastolic diameter indexed to body weight decreased in all dogs. Transcatheter coil embolization appears to be a safe and minimally invasive procedure for complete occlusion of residual PDA flow after incomplete surgical ligation. Transcatheter coil embolization should be considered for correction of hemodynamically significant residual shunts in dogs that have incomplete PDA occlusion after open surgical ligation.
Haggerty, Christopher M; Fynn-Thompson, Francis; McElhinney, Doff B; Valente, Anne Marie; Saikrishnan, Neelakantan; Del Nido, Pedro J; Yoganathan, Ajit P
2012-09-01
This study sought to evaluate the performance of microaxial ventricular assist devices for the purposes of supporting failing Fontan physiology by decreasing central venous pressure. Three Abiomed Impella pumps (Abiomed, Inc, Danvers, Mass) were evaluated in a mock circulatory system of the Fontan circuit. The local response of pressures and flows to pump function was assessed as a function of pump speed and pulmonary vascular resistance at a high baseline central venous pressure. For one device, subsequent modeling studies were conducted using a lumped parameter model of the single ventricle circuit. The left ventricular devices (Impella 2.5, 5.0) were shown to be suboptimal as single device solutions for cavopulmonary support. The small area of these devices relative to vessel diameter led to significant flow recirculation without an obstructive separator in place. Furthermore, downstream pressure augmentation adversely affected the pressure in the superior vena cava. The use of 2 devices would be mandatory for successful support. The right-sided device (Impella RP), whose outflow was positioned in the left pulmonary artery, demonstrated decreased flow recirculation and did not impede superior caval venous flow. Although static pressure is still required to drive flow through the opposite lung, numeric modeling demonstrated the potential for modest but significant improvements in lowering the central venous pressure (2-8 mm Hg). Left-sided microaxial pumps are not well suited for cavopulmonary support because of severe flow recirculation and the need for multiple devices. The right-ventricular Impella device provides improved performance by directing flow into the pulmonary artery, resulting in modest decreases in central venous pressure. Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Van Herck, P L; Carlier, S G; Claeys, M J; Haine, S E; Gorissen, P; Miljoen, H; Bosmans, J M; Vrints, C J
2007-01-01
Objective To investigate the underlying mechanisms of a decreased coronary flow reserve after myocardial infarction (MI) by analysing the characteristics of the diastolic hyperaemic coronary pressure–flow relationship. Design Prospective study. Setting Tertiary care hospital. Patients 68 patients with a recent MI and 27 patients with stable angina pectoris (AP; control group). Main outcome measures The intercept with the pressure axis (the zero flow pressure or Pzf) and slope index of the pressure–flow relationship (SIPF) were calculated from the simultaneously recorded hyperaemic intracoronary blood flow velocity and aortic pressure after successful coronary stenting. Results A stepwise increase in Pzf from AP (14.6 (8.0) mm Hg), over non‐Q‐wave MI (22.5 (9.1) mm Hg), to Q‐wave MI (37.1 (12.9) mm Hg; p<0.001) was observed. Similar changes in Pzf were found in a reference artery perfusing the non‐infarcted myocardium. Multivariate analysis showed that in both regions the left ventricular end‐diastolic pressure (LVEDP) was the most important determinant of the Pzf. The SIPF was not statistically different in the treated vessel between patients with MI and AP, but was increased in MI patients with a markedly increased LVEDP. Conclusions After an MI, the coronary pressure–flow relationship is shifted to the right both in the infarcted and in the non‐infarcted remote myocardium, as shown by the increased Pzf. The correlation with Pzf suggests that elevated left ventricular filling pressures contribute to the impediment of myocardial perfusion in patients with infarction. PMID:17395671
NASA Technical Reports Server (NTRS)
Pasquet, A.; Garcia, M. J.; Thomas, J. D.
1999-01-01
Over the past decade, Doppler echocardiography has become a well-established tool for the diagnosis of left ventricular diastolic dysfunction. Unfortunately, in many clinical situations traditional Doppler indices of transmittal and pulmonary venous flow are inconclusive, primarily due to their dependence on left atrial pressure. Recently, new Doppler indices that are much less dependent on preload have been developed, based on intraventricular flow propagation and intrinsic myocardial velocity. These methodologies provide direct assessment of ventricular relaxation and the small intraventricular pressure gradients essential to efficient filling of the ventricle. We review in this article the theoretical and experiment background of these new echo techniques as well as how they can be implemented in routine clinical practice.
Mycobacterium chimaera left ventricular assist device infections.
Balsam, Leora B; Louie, Eddie; Hill, Fred; Levine, Jamie; Phillips, Michael S
2017-06-01
A global outbreak of invasive Mycobacterium chimaera infections after cardiac surgery has recently been linked to bioaerosols from contaminated heater-cooler units. The majority of cases have occurred after valvular surgery or aortic graft surgery and nearly half have resulted in death. To date, infections in patients with left ventricular assist devices (LVADs) have not been characterized in the literature. We report two cases of device-associated M. chimaera infection in patients with continuous-flow LVADs and describe challenges related to diagnosis and management in this population. © 2017 Wiley Periodicals, Inc.
NASA Technical Reports Server (NTRS)
Koenig, S. C.; Ludwig, D. A.; Reister, C.; Fanton, J. W.; Ewert, D.; Convertino, V. A.
2001-01-01
Effects of prescribed doses of ketamine five minutes after application and influences of transesophageal echocardiography (TEE) on left ventricular, systemic arterial, and baroreflex responses were investigated to test the hypothesis that ketamine and/or TEE probe insertion alter cardiovascular function. Seven rhesus monkeys were tested under each of four randomly selected experimental conditions: (1) intravenous bolus dose of ketamine (0.5 ml), (2) continuous infusion of ketamine (500 mg/kg/min), (3) continuous infusion of ketamine (500 mg/kg/min) with TEE, and (4) control (no ketamine or TEE). Monkeys were chronically instrumented with a high fidelity, dual-sensor micromanometer to measure left ventricular and aortic pressure and a transit-time ultrasound probe to measure aortic flow. These measures were used to calculate left ventricular function. A 4-element Windkessel lumped-parameter model was used to estimate total peripheral resistance and systemic arterial compliance. Baroreflex response was calculated as the change in R-R interval divided by the change in mean aortic pressure measured during administration of graded concentrations of nitroprusside. The results indicated that five minutes after ketamine application heart rate and left ventricular diastolic compliance decreased while TEE increased aortic systolic and diastolic pressure. We conclude that ketamine may be administered as either a bolus or continuous infusion without affecting cardiovascular function 5 minutes after application while the insertion of a TEE probe will increase aortic pressure. The results for both ketamine and TEE illustrate the classic "Hawthorne Effect," where the observed values are partly a function of the measurement process. Measures of aortic pressure, heart rate, and left ventricular diastolic pressure should be viewed as relative, as opposed to absolute, when organisms are sedated with ketamine or instrumented with a TEE probe.
Martina, Jerson R; Westerhof, Berend E; de Jonge, Nicolaas; van Goudoever, Jeroen; Westers, Paul; Chamuleau, Steven; van Dijk, Diederik; Rodermans, Ben F M; de Mol, Bas A J M; Lahpor, Jaap R
2014-01-01
Arterial blood pressure and echocardiography may provide useful physiological information regarding cardiac support in patients with continuous-flow left ventricular assist devices (cf-LVADs). We investigated the accuracy and characteristics of noninvasive blood pressure during cf-LVAD support. Noninvasive arterial pressure waveforms were recorded with Nexfin (BMEYE, Amsterdam, The Netherlands). First, these measurements were validated simultaneously with invasive arterial pressures in 29 intensive care unit patients. Next, the association between blood pressure responses and measures derived by echocardiography, including left ventricular end-diastolic dimensions (LVEDDs), left ventricular end-systolic dimensions (LVESDs), and left ventricular shortening fraction (LVSF) were determined during pump speed change procedures in 30 outpatients. Noninvasive arterial blood pressure waveforms by the Nexfin monitor slightly underestimated invasive measures during cf-LVAD support. Differences between noninvasive and invasive measures (mean ± SD) of systolic, diastolic, mean, and pulse pressures were -7.6 ± 5.8, -7.0 ± 5.2, -6.9 ± 5.1, and -0.6 ± 4.5 mm Hg, respectively (all <10%). These blood pressure responses did not correlate with LVEDD, LVESD, or LVSF, while LVSF correlated weakly with both pulse pressure (r = 0.24; p = 0.005) and (dP(art)/dt)max (r = 0.25; p = 0.004). The dicrotic notch in the pressure waveform was a better predictor of aortic valve opening (area under the curve [AUC] = 0.87) than pulse pressure (AUC = 0.64) and (dP(art)/dt)max (AUC = 0.61). Patients with partial support rather than full support at 9,000 rpm had a significant change in systolic pressure, pulse pressure, and (dP(art)/dt)max during ramp studies, while echocardiographic measures did not change. Blood pressure measurements by Nexfin were reliable and may thereby act as a compliment to the assessment of the cf-LVAD patient.
Sjöberg, Pia; Bidhult, Sebastian; Bock, Jelena; Heiberg, Einar; Arheden, Håkan; Gustafsson, Ronny; Nozohoor, Shahab; Carlsson, Marcus
2018-04-17
Indications for pulmonary valve replacement (PVR) in patients with pulmonary regurgitation (PR) after repaired tetralogy of Fallot (rToF) are debated. We aimed to compare right (RV) and left ventricular (LV) kinetic energy (KE) measured by 4D-flow magnetic resonance imaging (MRI) in patients to controls, to further understand the pathophysiological effects of PR. Fifteen patients with rToF with PR > 20% and 14 controls underwent MRI. Ventricular volumes and KE were quantified from cine MRI and 4D-flow, respectively. Lagrangian coherent structures were used to discriminate KE in the PR. Restrictive RV physiology was defined as end-diastolic forward flow. LV systolic peak KE was lower in rToF, 2.8 ± 1.1 mJ, compared to healthy volunteers, 4.8 ± 1.1 mJ, p < 0.0001. RV diastolic peak KE was higher in rToF (7.7 ± 4.3 mJ vs 3.1 ± 1.3 mJ, p = 0.0001) and the difference most pronounced in patients with non-restrictive RV physiology. KE was primarily located in the PR volume at the time of diastolic peak KE, 64 ± 17%. This is the first study showing disturbed KE in patients with rToF and PR, in both the RV and LV. The role of KE as a potential early marker of ventricular dysfunction to guide intervention needs to be addressed in future studies. • Kinetic energy (KE) reflects ventricular performance • KE is a potential marker of ventricular dysfunction in Fallot patients • KE is disturbed in both ventricles in patients with tetralogy of Fallot • KE contributes to the understanding of the pathophysiology of pulmonary regurgitation • Lagrangian coherent structures enable differentiation of ventricular inflows.
Niwa, Koichiro
2017-12-01
Marfan syndrome, bicuspid aortic valve, and/or coarctation of the aorta are associated with medial abnormalities of the ascending aortic or para-coarctation aorta. Medial abnormalities in the ascending aorta are prevalent in other type of patients with a variety of CHDs such as single ventricle, persistent truncus arteriosus, transposition of the great arteries, hypoplastic left heart syndrome, and tetralogy of Fallot, encompassing a wide age range and may predispose to dilatation, aneurysm, and rapture necessitating aortic valve and root surgery. These CHDs exhibit ongoing dilatation of the aortic root and reduced aortic elasticity and increased aortic stiffness that may relate to intrinsic properties of the aortic root. These aortic dilatation and increased stiffness can induce aortic aneurysm, rapture of the aorta, and aortic regurgitation, but also provoke left ventricular hypertrophy, reduced coronary artery flow, and left ventricular failure. Therefore, a new clinical entity can be used to call this association of aortic pathophysiological abnormality, aortic dilation, and aorto-left ventricular interaction - "aortopathy".
Arvidsson, Per M; Töger, Johannes; Carlsson, Marcus; Steding-Ehrenborg, Katarina; Pedrizzetti, Gianni; Heiberg, Einar; Arheden, Håkan
2017-02-01
Intracardiac blood flow is driven by hemodynamic forces that are exchanged between the blood and myocardium. Previous studies have been limited to 2D measurements or investigated only left ventricular (LV) forces. Right ventricular (RV) forces and their mechanistic contribution to asymmetric redirection of flow in the RV have not been measured. We therefore aimed to quantify 3D hemodynamic forces in both ventricles in a cohort of healthy subjects, using magnetic resonance imaging 4D flow measurements. Twenty five controls, 14 elite endurance athletes, and 2 patients with LV dyssynchrony were included. 4D flow data were used as input for the Navier-Stokes equations to compute hemodynamic forces over the entire cardiac cycle. Hemodynamic forces were found in a qualitatively consistent pattern in all healthy subjects, with variations in amplitude. LV forces were mainly aligned along the apical-basal longitudinal axis, with an additional component aimed toward the aortic valve during systole. Conversely, RV forces were found in both longitudinal and short-axis planes, with a systolic force component driving a slingshot-like acceleration that explains the mechanism behind the redirection of blood flow toward the pulmonary valve. No differences were found between controls and athletes when indexing forces to ventricular volumes, indicating that cardiac force expenditures are tuned to accelerate blood similarly in small and large hearts. Patients' forces differed from controls in both timing and amplitude. Normal cardiac pumping is associated with specific force patterns for both ventricles, and deviation from these forces may be a sensitive marker of ventricular dysfunction. Reference values are provided for future studies. NEW & NOTEWORTHY Biventricular hemodynamic forces were quantified for the first time in healthy controls and elite athletes (n = 39). Hemodynamic forces constitute a slingshot-like mechanism in the right ventricle, redirecting blood flow toward the pulmonary circulation. Force patterns were similar between healthy subjects and athletes, indicating potential utility as a cardiac function biomarker. Copyright © 2017 the American Physiological Society.
[Initial experience with a new blood pump].
Margreiter, R; Schwab, W; Klima, G; Koller, J; Baum, M; Dietrich, H; Hager, J; Königsrainer, A
1990-12-01
A new type of blood pump was tested in calves for 6 hours. The pump consists of a rigid housing with a trochoidal internal surface, an inlet and outlet, and two lateral walls. A two-corner piston rotating on an eccentric shaft, describes a trochoidal path, thus creating a gap seal, the gap measuring a constant 10-35 microns. The pump is driven by a watercooled DC motor. For right ventricular assist, a cannula is inserted into the right ventricle through the right atrium, and into the left ventricle for left ventricular assists. From a total of 10 experiments, two left ventricular assists, two right ventricular assists, and three biventricular assists were evaluated. The pump produced a pulsatile flow of 31 at 70 rpm. Energy requirements were 2.19 watts for left, 2.06 for right, and 7.26 for biventricular assists. Plasma hemoglobin remained as low as 10 mg/dl during monoventricular, and increased during biventricular assists to 20 mg/dl after 3 hours, and returned to 16 mg/dl after 6 hours. From these preliminary results it is concluded that this new rotary blood pump may be suitable as a circulatory assist device.
Rotacor: a new rotary blood pump.
Margreiter, R; Schwab, W; Klima, G; Koller, J; Baum, M; Dietrich, H; Hager, J; Königsrainer, A
1990-01-01
A new rotary blood pump was tested in calves for 6 hr. The pump consists of a rigid housing with a trochoidal internal surface, an inlet and outlet, and two lateral walls. A two-corner piston rotates on an eccentric shaft in a trochoidal path, thus creating a gap seal. The pump is driven by a water-cooled DC motor. For right ventricular assist, a cannula was inserted into the right ventricle through the right atrium, and into the left ventricle for left ventricular assist. From a total of 10 experiments, two left ventricular assists, two right ventricular assists, and three biventricular assists were evaluated. The pump produced a pulsatile flow of 3 L at 70 rpm. Energy requirements were 2.19 watts for left, 2.06 for right, and 7.26 for biventricular assists. Plasma hemoglobin remained as low as 10 mg/dl during monoventricular, and increased during biventricular assists to 20 mg/dl after 3 hr, when it started to chop again; after 6 hr it was 16 mg/dl. From these preliminary results it is concluded that this new type of blood pump may be suitable as a circulatory assist device.
Ward, Jessica L; Schober, Karsten E; Fuentes, Virginia Luis; Bonagura, John D
2012-10-01
Although sedation is frequently used to facilitate patient compliance in feline echocardiography, the effects of sedative drugs on echocardiographic variables have been poorly documented. This study investigated the effects of two sedation protocols on echocardiographic indices in healthy cats, with special emphasis on the assessment of left atrial size and function, as well as left ventricular diastolic performance. Seven cats underwent echocardiography (transthoracic two-dimensional, spectral Doppler, color flow Doppler and tissue Doppler imaging) before and after sedation with both acepromazine (0.1 mg/kg IM) and butorphanol (0.25 mg/kg IM), or acepromazine (0.1 mg/kg IM), butorphanol (0.25 mg/kg IM) and ketamine (1.5 mg/kg IV). Heart rate increased significantly following acepromazine/butorphanol/ketamine (mean±SD of increase, 40±26 beats/min) and non-invasive systolic blood pressure decreased significantly following acepromazine/butorphanol (mean±SD of decrease, 12±19 mmHg). The majority of echocardiographic variables were not significantly different after sedation compared with baseline values. Both sedation protocols resulted in mildly decreased left ventricular end-diastolic dimension and mildly increased left ventricular end-diastolic wall thickness. This study therefore failed to demonstrate clinically meaningful effects of these sedation protocols on echocardiographic measurements, suggesting that sedation with acepromazine, butorphanol and/or ketamine can be used to facilitate echocardiography in healthy cats.
The late open infarct-related artery hypothesis: evidence-based medicine or not?
Brueck, Martin; Bandorski, Dirk; Kramer, Wilfried; Vogt, Paul R; Heidt, Martin C
2007-11-01
Randomized clinical trials have clearly shown that early reperfusion of coronary arteries is the established treatment of myocardial infarction preserving left ventricular function and reducing mortality. However, late patency of the infarct-related artery is an independent predictor of survival leading to the late open-artery hypothesis. This concept implies restoration of antegrade blood flow of the infarct-related artery in patients with myocardial infarction to improve survival by mechanisms less time-dependent or even time-independent. Possible explanations for this benefit include improved left ventricular function and electrical stability by perfusion of hibernating myocardium, accelerated infarct healing and limitation of ventricular remodeling. This review focuses on the evidence of late recanalization of occluded infarct-related arteries in patients with coronary artery disease.
Nguyen, Yen Ngoc; Ismail, Munirah; Kabinejadian, Foad; Tay, Edgar Lik Wui; Leo, Hwa Liang
2018-04-01
Intra-ventricular flow dynamics has recently emerged as an important evaluation and diagnosis tool in different cardiovascular conditions. The formation of vortex pattern during the cardiac cycle has been suggested to play important epigenetic and energy-modulation roles in cardiac remodelling, adaptations and mal-adaptations. In this new perspective, flow alterations due to different cardiovascular procedures can affect the long-term outcome of those procedures. Especially, repairs and replacements performed on atrioventricular valves are likely to exert direct impact on intra-ventricular flow pattern. In this review, current consensus around the roles of vortex dynamics in cardiac function is discussed. An overview of physiological vortex patterns found in healthy left and right ventricles as well as post-operative ventricular flow phenomenon owing to different atrioventricular valvular procedures are reviewed, followed by the summary of different vortex identification schemes used to characterise intraventricular flow. This paper also emphasises on future research directions towards a comprehensive understanding of intra-cardiac flow and its clinical relevance. The knowledge could encourage more effective pre-operative planning and better outcomes for current clinical practices. Copyright © 2018. Published by Elsevier Ltd.
The New Concept of Univentricular Heart
Frescura, Carla; Thiene, Gaetano
2014-01-01
The concept of univentricular heart moved from hearts with only one ventricle connected with atria [double inlet ventricle or absent atrioventricular (AV) connection] to hearts not amenable to biventricular repair, namely hearts with two ventricles unable to sustain separately pulmonary and systemic circulations in sequence. In the latter definition, even hearts with one hypoplastic ventricle are considered “functional” univentricular hearts. They include pulmonary/aortic atresia or severe stenosis with hypoplastic ventricle, and rare conditions like huge intramural cardiac tumors and Ebstein anomaly with extreme atrialization of right ventricular cavity. In this setting, the surgical repair is univentricular with “Fontan” operation, bypassing the ventricular mass. In other words, functionally univentricular heart is a condition in which, after surgery, only one ventricle sustain systemic circulation. Univentricular hearts (double inlet or absent AV connection) almost invariably show two ventricular chambers, one main and one accessory, which lacks an inlet portion. The latter is located posteriorly when morphologically left and anteriorly when morphologically right. As far as double inlet left ventricle, this is usually associated with discordant ventriculo-arterial (VA) connection (transposition of the great arteries) and all the blood flow to the aorta, which takes origin from the hypoplastic anterior right ventricle, is ventricular septal defect (bulbo-ventricular foramen) dependent. If restrictive, an aortic arch obstruction may be present. Double inlet left ventricle may be rarely associated with VA concordance (Holmes heart). As far as double inlet right ventricle with posterior hypoplastic left ventricular cavity, ventriculo-arterial connection is usually of double outlet type; thus the term double inlet–outlet right ventricle may be coined. Absent right or left AV connection may develop in the setting of both d- or l-loop, whatever the situs. In this condition, the contra-lateral patent AV valve may be either mitral or tricuspid in terms of morphology and the underlying ventricle (main chamber) either morphologically left or right. Establishing the loop, whatever right or left (also called right or left ventricular topology), is a fundamental step in the segmental-sequential analysis of congenital heart disease. PMID:25072035
Moreno, Beatriz; de Faria, Ana Paula; Ritter, Alessandra Mileni Versuti; Yugar, Lara Buonalumi Tacito; Ferreira-Melo, Silvia Elaine; Amorim, Rivadavio; Modolo, Rodrigo; Fattori, André; Yugar-Toledo, Juan Carlos; Coca, Antonio; Moreno, Heitor
2018-05-01
This study aimed to evaluate the effects of glycated hemoglobin (HbA 1c ) on flow-mediated dilation, intima-media thickness, pulse wave velocity, and left ventricular mass index in patients with resistant hypertension (RHTN) comparing RHTN-controlled diabetes mellitus and RHTN-uncontrolled type 2 diabetes mellitus. Two groups were formed: HbA 1c <7.0% (RHTN-controlled diabetes mellitus: n = 98) and HbA 1c ≥7.0% (RHTN-uncontrolled diabetes mellitus: n = 122). Intima-media thickness and flow-mediated dilation were measured by high-resolution ultrasound, left ventricular mass index by echocardiography, and arterial stiffness by carotid-femoral pulse wave velocity. No differences in blood pressure levels were found between the groups but body mass index was higher in patients with RHTN-uncontrolled diabetes mellitus. Endothelial dysfunction and arterial stiffness were worse in patients with RHTN-uncontrolled diabetes mellitus. Intima-media thickness and left ventricular mass index measurements were similar between the groups. After adjustments, multiple linear regression analyses showed that HbA 1c was an independent predictor of flow-mediated dilation and pulse wave velocity in all patients with RHTN. In conclusion, HbA 1c may predict the grade of arterial stiffness and endothelial dysfunction in patients with RHTN, and superimposed uncontrolled diabetes mellitus implicates further impairment of vascular function. ©2018 Wiley Periodicals, Inc.
Burattini, R; Sipkema, P; van Huis, G A; Westerhof, N
1985-01-01
This study was performed to elucidate the effects of cardiac contraction on coronary pressure-flow relations. On the basis of the waterfall mechanism, a lumped model of the coronary arterial system is presented consisting of a proximal (epicardial) compliance, a coronary resistance, and an intramyocardial compliance. A "back"-pressure, assumed to be proportional (constant k) to left ventricular pressure, impedes flow. From steady-state measurements of circumflex coronary artery flow and inflow pressure, together with left ventricular pressure, the values of the three model parameters and the constant k have been estimated. In the control condition proximal compliance is found to be 1.7 X 10(-12) m4s2kg-1, intramyocardial compliance 110 X 10(-12)m4s2kg-1, and resistance 7.5 X 10(9) kgm-4s-1. The proportionality constant k is close to unity. Effects of changes in left ventricular pressure and inflow pressure and the effect of vasoactive drugs on the parameters are also investigated. Changes in coronary resistance are always opposite to changes in intramyocardial compliance. Sensitivity analysis showed that epicardial compliance plays its major role during isovolumic contraction and relaxation; resistance plays a role throughout the cardiac cycle but is more important in diastole than in systole, whereas intramyocardial compliance plays a role in systole and in early diastole.
Stevens, Michael C; Wilson, Stephen; Bradley, Andrew; Fraser, John; Timms, Daniel
2014-09-01
Dual rotary left ventricular assist devices (LVADs) can provide biventricular mechanical support during heart failure. Coordination of left and right pump speeds is critical not only to avoid ventricular suction and to match cardiac output with demand, but also to ensure balanced systemic and pulmonary circulatory volumes. Physiological control systems for dual LVADs must meet these objectives across a variety of clinical scenarios by automatically adjusting left and right pump speeds to avoid catastrophic physiological consequences. In this study we evaluate a novel master/slave physiological control system for dual LVADs. The master controller is a Starling-like controller, which sets flow rate as a function of end-diastolic ventricular pressure (EDP). The slave controller then maintains a linear relationship between right and left EDPs. Both left/right and right/left master/slave combinations were evaluated by subjecting them to four clinical scenarios (rest, postural change, Valsalva maneuver, and exercise) simulated in a mock circulation loop. The controller's performance was compared to constant-rotational-speed control and two other dual LVAD control systems: dual constant inlet pressure and dual Frank-Starling control. The results showed that the master/slave physiological control system produced fewer suction events than constant-speed control (6 vs. 62 over a 7-min period). Left/right master/slave control had lower risk of pulmonary congestion than the other control systems, as indicated by lower maximum EDPs (15.1 vs. 25.2-28.4 mm Hg). During exercise, master/slave control increased total flow from 5.2 to 10.1 L/min, primarily due to an increase of left and right pump speed. Use of the left pump as the master resulted in fewer suction events and lower EDPs than when the right pump was master. Based on these results, master/slave control using the left pump as the master automatically adjusts pump speed to avoid suction and increases pump flow during exercise without causing pulmonary venous congestion. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Effect of free fatty acids on myocardial function and metabolism in the ischemic dog heart
Kjekshus, John K.; Mjøs, Ole D.
1972-01-01
Since elevation of plasma concentrations of free fatty acids (FFA) increases myocardial oxygen consumption without influencing mechanical performance in normal hearts, it was the purpose of this study to determine whether FFA would modify mechanical performance at limited oxygen supply. Left coronary blood flow was reduced by gradual clamping of a shunt from the left carotid artery until moderate ventricular dilatation supervened. Left ventricular systolic pressure (LVSP), its maximal rate of rise (dP/dt) and stroke volume (SV) were unchanged or slightly reduced. The ischemia resulted in a decrease in myocardial oxygen consumption (MVO2) from 9.7±1.1 ml/min to 7.9±0.8 ml/min, and myocardial lactate uptake was reduced or reversed to excretion. Increasing the plasma concentrations of FFA from 359±47 μEq/1 to 3688±520 μEq/1 by intravenous infusion of a triglyceride emulsion and heparin resulted in further ventricular dilatation, accompanied by increased excretion of lactate. The ventricular decompensation and enhancement of anaerobic myocardial metabolism associated with increased uptake of FFA was not related to changes in coronary flow, MVO2, or LVSP. dP/dt and SV were virtually unchanged. Intravenous infusion of glucose/insulin, which lowered plasma concentrations of FFA, reversed ventricular dilatation and lactate excretion. The data support the hypothesis that high concentrations of FFA play a significant role in increasing myocardial oxygen requirement and thereby promote depression of contractility of the hypoxic heart in experimental animals. Images PMID:5032525
Use of a Left Ventricular Assist Device as a Bridge to Transplantation in a Pediatric Patient
Frazier, O.H.; Bricker, J. Timothy; Macris, Michael P.; Cooley, Denton A.
1989-01-01
Despite many advances in heart transplantation and in mechanical circulatory support, the benefits of staged cardiac transplantation have not been extended to the pediatric transplant recipient, chiefly because implantable circulatory assist devices are still too large. Extracorporeal devices, however, can overcome this impediment. Here we report the 1st case, to our knowledge, in which an extracorporeal left ventricular assist device has been used in a child to support circulation prior to cardiac transplantation. The patient was a 9-year-old boy in New York Heart Association functional class IV, with congestive heart failure as a result of idiopathic biventricular cardiomegaly. In mid-May of 1987, while awaiting a suitable donor, he suffered severe oliguria after an episode of circulatory arrest. Therefore we decided to maintain his circulation—and consequently his peripheral organ function—with an extracorporeal left ventricular assist device. After establishing cardiopulmonary bypass under normothermia and without cardiac arrest, we established flow from the left ventricle through a 36-Fr wire-reinforced straight cannula to a Biomedicus BP-80 centrifugal force pump, with return to the proximal ascending aorta through a 28-Fr wire-reinforced straight cannula. The patient's hemodynamic course under subsequent mechanical circulatory support was remarkably stable, with controllable systemic hypertension and no evidence of hemolysis. Although cardiac activity was minimal and systemic blood flow nonpulsatile, the patient's renal, pulmonary, and hepatic functions improved, and his peripheral circulation was well preserved. After 12 hours of support, a donor heart became available, and a routine orthotopic cardiac transplant was performed. Upon removal, the left ventricular assist device showed a small amount of thrombus formation. The patient's postoperative recovery has been easily manageable, and 20 months after transplant he enjoys unrestricted physical activity. We conclude that an extracorporeal left ventricular assist device can be used as a bridge to cardiac transplantation in children. Moreover, this application of a continuous force centrifugal pump without adverse effect encourages the conclusion that long-term maintenance of terminal heart disease patients might be possible through development of small, implantable pumps with the potential of lower power requirements and reduced thrombogenesis. (Texas Heart Institute Journal 1989;16:46-50) PMID:15227237
Atluri, Pavan; Fairman, Alexander S.; MacArthur, John W.; Goldstone, Andrew B.; Cohen, Jeffrey E.; Howard, Jessica L.; Zalewski, Christyna M.; Shudo, Yasuhiro; Woo, Y. Joseph
2014-01-01
Background Continuous flow left ventricular assist devices (CF LVAD) are being implanted with increasing frequency for end-stage heart failure. At the time of LVAD implant, a large proportion of patients have pulmonary hypertension, right ventricular (RV) dysfunction, and tricuspid regurgitation (TR). RV dysfunction and TR can exacerbate renal dysfunction, hepatic dysfunction, coagulopathy, edema, and even prohibit isolated LVAD implant. Repairing TR mandates increased cardiopulmonary bypass time and bicaval cannulation, which should be reserved for the time of orthotopic heart transplantation. We hypothesized that CF LVAD implant would improve pulmonary artery pressures, enhance RV function, and minimize TR, obviating need for surgical tricuspid repair. Methods One hundred fourteen continuous flow LVADs implanted from 2005 through 2011 at a single center, with medical management of functional TR, were retrospectively analyzed. Pulmonary artery pressures were measured immediately prior to and following LVAD implant. RV function and TR were graded according to standard echocardiographic criteria, prior to, immediately following, and long-term following LVAD. Results There was a significant improvement in post-VAD mean pulmonary arterial pressures (26.6 ± 4.9 vs. 30.2 ± 7.4 mmHg, p = 0.008) with equivalent loading pressures (CVP = 12.0 ± 4.0 vs. 12.1 ± 5.1 p = NS). RV function significantly improved, as noted by right ventricular stroke work index (7.04 ± 2.60 vs. 6.05 ± 2.54, p = 0.02). There was an immediate improvement in TR grade and RV function following LVAD implant, which was sustained long term. Conclusion Continuous flow LVAD implant improves pulmonary hypertension, RV function, and tricuspid regurgitation. TR may be managed nonoperatively during CF LVAD implant. PMID:24118109
Lee, Chih-Hsien; Wei, Jeng
The prevalence of end-stage heart failure (HF) is on the increase, however, the availability of donor hearts remains limited. Left ventricular assist devices (LVADs) are increasingly being used for treating patients with end-stage HF. LVADs are not only used as a bridge to transplantation but also as a destination therapy. HeartMate II, a new-generation, continuous-flow LVAD (cf-LVAD), is currently an established treatment option for patients with HF. Technological progress and increasing implantation of cf-LVADs have significantly improved survival in patients with end-stage HF. Here we report a case of a patient with end-stage HF who was successfully supported using cf-LVAD implantation with adjuvant tricuspid valve repair in a general district hospital.
Bozkurt, Selim; van de Vosse, Frans N; Rutten, Marcel C M
Continuous-flow left ventricular assist devices (CF-LVADs) generally operate at a constant speed, which reduces pulsatility in the arteries and may lead to complications such as functional changes in the vascular system, gastrointestinal bleeding, or both. The purpose of this study is to increase the arterial pulse pressure and pulsatility by controlling the CF-LVAD flow rate. A MicroMed DeBakey pump was used as the CF-LVAD. A model simulating the flow rate through the aortic valve was used as a reference model to drive the pump. A mock circulation containing two synchronized servomotor-operated piston pumps acting as left and right ventricles was used as a circulatory system. Proportional-integral control was used as the control method. First, the CF-LVAD was operated at a constant speed. With pulsatile-speed CF-LVAD assistance, the pump was driven such that the same mean pump output was generated. Continuous and pulsatile-speed CF-LVAD assistance provided the same mean arterial pressure and flow rate, while the index of pulsatility increased significantly for both arterial pressure and pump flow rate signals under pulsatile speed pump support. This study shows the possibility of improving the pulsatility of CF-LVAD support by regulating pump speed over a cardiac cycle without reducing the overall level of support.
Huang, Bao-Tao; Peng, Yong; Liu, Wei; Zhang, Chen; Huang, Fang-Yang; Wang, Peng-Ju; Zuo, Zhi-Liang; Liao, Yan-Biao; Chai, Hua; Li, Qiao; Zhao, Zhen-Gang; Luo, Xiao-Lin; Ren, Xin; Huang, Kai-Sen; Meng, Qing-Tao; Chen, Chi; Huang, De-Jia; Chen, Mao
2015-03-01
Although inappropriate left ventricular mass has been associated with clustered cardiac geometric and functional abnormalities, its predictive value in patients with coronary artery disease is still unknown. This study examined the association of inappropriate left ventricular mass with clinical outcomes in patients with angina pectoris and normal ejection fraction. Consecutive patients diagnosed with angina pectoris whose ejection fraction was normal were recruited from 2008 to 2012. Inappropriate left ventricular mass was determined when the ratio of actual left ventricular mass to the predicted one exceeded 150%. The primary endpoint was a composite of all-cause death, nonfatal myocardial infarction, and nonfatal stroke. Clinical outcomes between the inappropriate and appropriate left ventricular mass group were compared before and after propensity matching. Of the total of 1515 participants, 18.3% had inappropriate left ventricular mass. Patients with inappropriate left ventricular mass had a higher composite event rate compared with those with appropriate left ventricular mass (11.2 vs. 6.6%, P=0.010). Multivariate Cox regression analyses showed that inappropriate left ventricular mass was an independent risk factor for adverse events (adjusted hazard ratio, 1.59; 95% confidence interval, 1.03-2.45; P=0.035). The worse outcome in patients with inappropriate left ventricular mass was further validated in a propensity matching cohort and patients with the traditional definition of left ventricular hypertrophy. Inappropriate left ventricular mass was associated with an increased risk of adverse events in patients with angina pectoris and normal ejection fraction.
Kishimoto, Satoru; Takewa, Yoshiaki; Tsukiya, Tomonori; Mizuno, Toshihide; Date, Kazuma; Sumikura, Hirohito; Fujii, Yutaka; Ohnuma, Kentaro; Togo, Konomi; Katagiri, Nobumasa; Naito, Noritsugu; Kishimoto, Yuichiro; Nakamura, Yoshinobu; Nishimura, Motonobu; Tatsumi, Eisuke
2018-03-01
The management of heart failure patients presenting in a moribund state remains challenging, despite significant advances in the field of ventricular assist systems. Bridge to decision involves using temporary devices to stabilize the hemodynamic state of such patients while further assessment is performed and a decision can be made regarding patient management. We developed a new temporary left ventricular assist system employing a disposable centrifugal pump with a hydrodynamically levitated bearing. We used three adult goats (body weight, 58-68 kg) to investigate the 30-day performance and hemocompatibility of the newly developed left ventricular assist system, which included the pump, inflow and outflow cannulas, the extracorporeal circuit, and connectors. Hemodynamic, hematologic, and blood chemistry measurements were investigated as well as end-organ effect on necropsy. All goats survived for 30 days in good general condition. The blood pump was operated at a rotational speed of 3000-4500 rpm and a mean pump flow of 3.2 ± 0.6 L min. Excess hemolysis, observed in one goat, was due to the inadequate increase in pump rotational speed in response to drainage insufficiency caused by continuous contact of the inflow cannula tip with the left ventricular septal wall in the early days after surgery. At necropsy, no thrombus was noted in the pump, and no damage caused by mechanical contact was found on the bearing. The newly developed temporary left ventricular assist system using a disposable centrifugal pump with hydrodynamic bearing demonstrated consistent and satisfactory hemodynamic performance and hemocompatibility in the goat model.
Effect of atrial systole on canine and porcine coronary blood flow.
Bellamy, R F
1981-09-01
A feature of phasic coronary flow patterns recorded in conscious chronically instrumented dogs is the atrial cove--a transient depression of arterial flow that occurs during atrial systole. The association between the hemodynamic effects of atrial systole and the atrial cove was studied in anesthetized dogs and pigs with complete heart block. Many atrial coves are available for study in these preparations because atrial activity continues unabated during the diastolic ventricular arrest that follows cessation of electrical pacing. The effect of atrial systole is to translate the pressure-flow relation found during diastole to a higher intercept pressure without change in slope. The increase in the intercept pressure equals the increase in intramyocardial pressure measured with microtransducers embedded in the left ventricular wall. The decrement in flow during the atrial cove is a direct function of the change in intramyocardial pressure and an inverse function of coronary vascular resistance. Each atrial systole is associated with a forward flow transient in the coronary veins, the peak of which occurs at the same instant as does the nadir of atrial flow. These data suggest that the coronary vessels are acting as collapsible tubes and that the waterfall model of the coronary circulation is applicable. The following sequence is proposed to account for the atrial cove. Atrial systole ejects a bolus of blood into the left ventricle increasing both ventricular cavity and intramyocardial pressures. The increase in intramyocardial pressure raises the back pressure opposing coronary flow, reducing the arterial perfusion pressure gradient and causing flow to fall.
Shan, Shengshuai; He, Xiaoxiao; He, Lin; Wang, Min; Liu, Chengyun
2017-08-19
The coexistence of congenital left ventricular aneurysm and abnormal cardiac trabeculation with gene mutation has not been reported previously. Here, we report a case of coexisting congenital left ventricular aneurysm and prominent left ventricular trabeculation in a patient with LIM domain binding 3 gene mutation. A 30-year-old Asian man showed paroxysmal sinus tachycardia and Q waves in an electrocardiogram health check. There were no specific findings in physical examinations and serological tests. A coronary-computed tomography angiography check showed normal coronary artery and no coronary stenosis. Both left ventricle contrast echocardiography and cardiac magnetic resonance showed rare patterns of a combination of an apical aneurysm-like out-pouching structure with a wide connection to the left ventricle and prominent left ventricular trabecular meshwork. High-throughput sequencing examinations showed a novel mutation in the LDB3 gene (c.C793>T; p.Arg265Cys). Our finding indicates that the phenotypic expression of two heart conditions, congenital left ventricular aneurysm and prominent left ventricular trabeculation, although rare, can occur simultaneously with LDB3 gene mutation. Congenital left ventricular aneurysm and prominent left ventricular trabeculation may share the same genetic background.
Vamvakidou, Anastasia; Jin, Wenying; Danylenko, Oleksandr; Chahal, Navtej; Khattar, Rajdeep; Senior, Roxy
2018-03-09
This study aimed to assess the value of low transvalvular flow rate (FR) for the prediction of mortality compared with low stroke volume index (SVi) in patients with low-gradient (mean gradient: <40 mm Hg), low aortic valve area (<1 cm 2 ) aortic stenosis (AS) following aortic valve intervention. Transaortic FR defined as stroke volume/left ventricular ejection time is also a marker of flow; however, no data exist comparing the relative prognostic value of these 2 transvalvular flow markers in patients with low-gradient AS who had undergone valve intervention. We retrospectively followed prospectively assessed consecutive patients with low-gradient, low aortic valve area AS who underwent aortic valve intervention between 2010 and 2014 for all-cause mortality. Of the 218 patients with mean age 75 ± 12 years, 102 (46.8%) had low stroke volume index (SVi) (<35 ml/m 2 ), 95 (43.6%) had low FR (<200 ml/s), and 58 (26.6%) had low left ventricular ejection fraction <50%. The concordance between FR and SVi was 78.8% (p < 0.005). Over a median follow-up of 46.8 ± 21 months, 52 (23.9%) deaths occurred. Patients with low FR had significantly worse outcome compared with those with normal FR (p < 0.005). In patients with low SVi, a low FR conferred a worse outcome than a normal FR (p = 0.005), but FR status did not discriminate outcome in patients with normal SVi. By contrast, SVi did not discriminate survival either in patients with normal or low FR. Low FR was an independent predictor of mortality (p = 0.013) after adjusting for age, clinical prognostic factors, European System for Cardiac Operative Risk Evaluation II, dimensionless velocity index, left ventricular mass index, left ventricular ejection fraction, heart rate, time, type of aortic valve intervention, and SVi (p = 0.59). In patients with low-gradient, low valve area aortic stenosis undergoing aortic valve intervention, low FR, not low SVi, was an independent predictor of medium-term mortality. Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Topilsky, Yan; Oh, Jae K; Atchison, Fawn W; Shah, Dipesh K; Bichara, Valentina M; Schirger, John A; Kushwaha, Sudhir S; Pereira, Naveen L; Park, Soon J
2011-02-01
Continuous-flow left ventricular assist devices (LVADs) have become part of the standard of care for the treatment of advanced heart failure. However, knowledge of normal values for transthoracic echocardiographic examination and measurements in these patients are lacking. All transthoracic echocardiographic examinations in 63 consecutive patients, performed 90 and 180 days after surgery with the implantation of a HeartMate II continuous-flow LVAD between February 2007 and January 2010, were retrospectively analyzed. All patients had to be outpatients at 3 and 6 months after surgery and considered stable on LVAD therapy (New York Heart Association class I or II and no need for inotropes, intravenous furosemide, or hospitalization). End-diastolic and end-systolic diameters and left ventricular mass decreased considerably compared with baseline measurements before LVAD implantation. Mitral inflow deceleration time increased (188 ± 70 vs 132.5 ± 27 msec, P = .009) and left atrial volume (84.1 ± 33 vs 141.7 ± 62 mL, P = .003) and E/e' ratio decreased (20.3 ± 9 vs 26 ± 11, P = .01), all consistent with decreased left ventricular filling pressure. Estimated right ventricular (RV) and right atrial pressure decreased significantly (34.1 ± 10 vs 51.7 ± 14 mm Hg and 9.5 ± 5 vs 14.4 ± 5 mm Hg, respectively, P < .0001 for both). Quantitatively estimated RV function (P = .02), RV fractional area change (27.9 ± 10% vs 37.4 ± 10.9%, P < .0001), and the RV index of myocardial performance (0.32 ± 0.1 vs 0.65 ± 0.2 vs 0.32 ± .01, P < .0001) improved, suggesting improved RV efficiency. LVAD therapy resulted in significant decreases in the severity of mitral regurgitation. Tricuspid regurgitation improved in patients who had concurrent tricuspid surgical correction and was unchanged otherwise. Aortic regurgitation severity increased 3 months after LVAD implantation. There were no significant differences in any of the echocardiographic parameters in the 6-month evaluation compared with the 3-month evaluation. This is the first report of selected typical echocardiographic values in a group of stable patients with normally functioning HeartMate II continuous-flow LVADs. A stable functioning continuous LVAD is associated with evidence of efficient unloading of the left ventricle, improved RV function, significant improvement in mitral regurgitation, improvement in tricuspid regurgitation only in patients undergoing repair, and increased aortic regurgitation. These normal data provide a basis for future echocardiographic studies after LVAD implantation. Copyright © 2011 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.
Partitioned fluid-solid coupling for cardiovascular blood flow: left-ventricular fluid mechanics.
Krittian, Sebastian; Janoske, Uwe; Oertel, Herbert; Böhlke, Thomas
2010-04-01
We present a 3D code-coupling approach which has been specialized towards cardiovascular blood flow. For the first time, the prescribed geometry movement of the cardiovascular flow model KaHMo (Karlsruhe Heart Model) has been replaced by a myocardial composite model. Deformation is driven by fluid forces and myocardial response, i.e., both its contractile and constitutive behavior. Whereas the arbitrary Lagrangian-Eulerian formulation (ALE) of the Navier-Stokes equations is discretized by finite volumes (FVM), the solid mechanical finite elasticity equations are discretized by a finite element (FEM) approach. Taking advantage of specialized numerical solution strategies for non-matching fluid and solid domain meshes, an iterative data-exchange guarantees the interface equilibrium of the underlying governing equations. The focus of this work is on left-ventricular fluid-structure interaction based on patient-specific magnetic resonance imaging datasets. Multi-physical phenomena are described by temporal visualization and characteristic FSI numbers. The results gained show flow patterns that are in good agreement with previous observations. A deeper understanding of cavity deformation, blood flow, and their vital interaction can help to improve surgical treatment and clinical therapy planning.
Smolich, Joseph J
2014-02-15
Although a reduction in lung liquid volume increases fetal pulmonary blood flow, the changes in central flow patterns that sustain this increased pulmonary perfusion are unknown. To address this issue, eight anesthetized late-gestation fetal sheep were instrumented with pulmonary trunk (PT), ductus arteriosus (DA), and left pulmonary artery (PA) micromanometer catheters and transit-time flow probes, with blood flow profile and wave intensity analyses performed at baseline and after withdrawal of lung liquid via an endotracheal tube. Reducing lung liquid volume by 19 ± 6 ml/kg (mean ± SD) augmented right ventricular power by 34% (P < 0.001), with distribution of an accompanying increase in mean PT blood flow (245 ± 63 ml/min, P < 0.001) to the lungs (169 ± 91 ml/min, P = 0.001) and across the DA (77 ± 92 ml/min, P = 0.04). However, although PT and DA flow increments were confined to systole and were related to an increased magnitude of flow-increasing, forward-running compression waves, the rise in PA flow spanned both systole (108 ± 66 ml/min) and diastole (61 ± 32 ml/min). Flow profile analysis showed that the step-up in PA diastolic flow was associated with diminished PA diastolic backflow and accompanied by a lesser degree of diastolic right-to-left DA shunting. These data suggest that an increased pulmonary blood flow after reduction of lung liquid volume is associated with substantial changes in PT-DA-PA interactions and underpinned by two main factors: 1) enhanced right ventricular pump function that increases PA systolic inflow and 2) decreased PA diastolic backflow that arises from a fundamental change in PA reservoir function, thereby resulting in greater passage of systolic inflow through the lungs.
Li, Bin; Yang, Hui; Wang, Xiaochen; Zhan, Yongkun; Sheng, Wei; Cai, Huanhuan; Xin, Haoyang; Liang, Qianqian; Zhou, Ping; Lu, Chao; Qian, Ruizhe; Chen, Sifeng; Yang, Pengyuan; Zhang, Jianyi; Shou, Weinian; Huang, Guoying; Liang, Ping; Sun, Ning
2017-09-29
Most infarctions occur in the left anterior descending coronary artery and cause myocardium damage of the left ventricle. Although current pluripotent stem cells (PSCs) and directed cardiac differentiation techniques are able to generate fetal-like human cardiomyocytes, isolation of pure ventricular cardiomyocytes has been challenging. For repairing ventricular damage, we aimed to establish a highly efficient purification system to obtain homogeneous ventricular cardiomyocytes and prepare engineered human ventricular heart muscles in a dish. The purification system used TALEN-mediated genomic editing techniques to insert the neomycin or EGFP selection marker directly after the myosin light chain 2 (MYL2) locus in human pluripotent stem cells. Purified early ventricular cardiomyocytes were estimated by immunofluorescence, fluorescence-activated cell sorting, quantitative PCR, microelectrode array, and patch clamp. In subsequent experiments, the mixture of mature MYL2-positive ventricular cardiomyocytes and mesenchymal cells were cocultured with decellularized natural heart matrix. Histological and electrophysiology analyses of the formed tissues were performed 2 weeks later. Human ventricular cardiomyocytes were efficiently isolated based on the purification system using G418 or flow cytometry selection. When combined with the decellularized natural heart matrix as the scaffold, functional human ventricular heart muscles were prepared in a dish. These engineered human ventricular muscles can be great tools for regenerative therapy of human ventricular damage as well as drug screening and ventricular-specific disease modeling in the future.
Heerdt, P M; Pond, C G; Kussman, M K; Triantafillou, A N
1993-01-01
Despite numerous technologic advances in intraoperative monitoring, the only methods routinely available for assessment of right ventricular function in lung transplant recipients are continuous measurement of right heart pressures and intermittent thermodilution determination of cardiac output and ejection fraction. Additional data may now be obtained with transesophageal echocardiography, although this technology is expensive and not widely available and requires diverting attention from a potentially unstable patient for data acquisition and analysis. Recently, a Doppler pulmonary artery catheter was introduced that measures beat-to-beat pulmonary artery blood flow-velocity, cross sectional area, and volume flow. Because of data indicating that acceleration of blood in the pulmonary artery (measured as the first derivative of either the velocity or flow waveform) is a sensitive indicator of right ventricular contractility, we have used waveforms obtained with the catheter for assessment of right ventricular pump function (stroke volume and peak pulmonary artery flow rate) and contractility in heart surgery patients. We report here our experience with this method in two patients undergoing left single lung transplantation.
Importance of the mitral apparatus for left ventricular function: an experimental approach.
Gams, E; Hagl, S; Schad, H; Heimisch, W; Mendler, N; Sebening, F
1992-01-01
In an experimental study of 31 anesthetized dogs the importance of the mitral apparatus for the left ventricular function was investigated. During extracorporeal circulation bileaflet mitral valve prostheses were implanted preserving the mitral subvalvular apparatus. Flexible wires were slung around the chordae tendineae and exteriorized through the left ventricular wall to cut the chordae by electrocautery from the outside when the heart was beating again. External and internal left ventricular dimensions were measured by sonomicrometry, left ventricular stroke volume by electromagnetic flowmeters around the ascending aorta, left ventricular end-diastolic volume by dye dilution technique, and left ventricular pressure by catheter tip manometers. Different preload levels were achieved by volume loading with blood transfusion before and after cutting the chordae tendineae. When the chordae had been divided peak systolic left ventricular pressure did not change. Heart rate only increased at the lowest left ventricular end-diastolic pressures of 3-4 mmHg, but remained unchanged at higher preload levels. Cardiac output decreased significantly up to -9% at left ventricular end-diastolic pressures of 5-10 mmHg, while left ventricular dp/dtmax showed a consistent reduction of up to -15% at any preload level. Significant reductions were also seen in systolic shortening in the left ventricular major axis (by external measurements -27%, by internal recording -43%). Left ventricular end-diastolic dimensions increased in the major axis by +2% when recorded externally, by +10% when measured internally. Systolic and diastolic changes in the minor axis were not consistent and different in the external and internal recordings.(ABSTRACT TRUNCATED AT 250 WORDS)
Wave energy patterns of counterpulsation: a novel approach with wave intensity analysis.
Lu, Pong-Jeu; Yang, Chi-Fu Jeffrey; Wu, Meng-Yu; Hung, Chun-Hao; Chan, Ming-Yao; Hsu, Tzu-Cheng
2011-11-01
In counterpulsation, diastolic augmentation increases coronary blood flow and systolic unloading reduces left ventricular afterload. We present a new approach with wave intensity analysis to revisit and explain counterpulsation principles. In an acute porcine model, a standard intra-aortic balloon pump was placed in descending aorta in 4 pigs. We measured pressure and velocity with probes in left anterior descending artery and aorta during and without intra-aortic balloon pump assistance. Wave intensities of aortic and left coronary waves were derived from pressure and flow measurements with synchronization correction. We identified predominating waves in counterpulsation. In the aorta, during diastolic augmentation, intra-aortic balloon inflation generated a backward compression wave, with a "pushing" effect toward the aortic root that translated to a forward compression wave into coronary circulation. During systolic unloading, intra-aortic balloon pump deflation generated a backward expansion wave that "sucked" blood from left coronary bed into the aorta. While this backward expansion wave translated to reduced left ventricular afterload, the "sucking" effect resulted in left coronary blood steal, as demonstrated by a forward expansion wave in left anterior descending coronary flow. The waves were sensitive to inflation and deflation timing, with just 25 ms delay from standard deflation timing leading to weaker forward expansion wave and less coronary regurgitation. Intra-aortic balloon pumps generate backward-traveling waves that predominantly drive aortic and coronary blood flow during counterpulsation. Wave intensity analysis of arterial circulations may provide a mechanism to explain diastolic augmentation and systolic unloading of intra-aortic balloon pump counterpulsation. Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Asymptomatic young man with an incidental murmur.
Shojaeifard, Maryam; Pouraliakbar, Hamid Reza; Houshmand, Golnaz
2018-05-31
A 32-year old man was referred to our institution for transthoracic echocardiography (TTE) following detection of an incidental murmur on physical examination before blood donation. He was asymptomatic with no significant medical history. Physical examination revealed dual heart sounds with a grade II/VI systolic murmur heard in the left sternal border. An ECG was in normal sinus rhythm. TTE was performed (figure 1A-C, online supplementary videos 1-4) followed by cardiac CT angiography (CTA) (figure 1D,E).heartjnl;heartjnl-2018-313223v1/F1F1F1Figure 1(A) Transthoracic echocardiography, parasternal left ventricular long axis view. (B) Colour Doppler of modified short axis in the mid-left ventricular level. (C) Doppler flow velocity profile. (D) Cardiac CT angiography (CTA) sagittal reconstruction. (E) Three-dimensional CTA reconstruction of the heart. What is the diagnosis?Pericardial cyst.Ventricular septal defect.Kawasaki.Anomalous left coronary artery from pulmonary artery (ALCAPA). © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Jijeh, Abdulraouf; Ismail, Muna; Alhabshan, Fahad
2017-09-01
Ventricular septal defect and aortic arch obstruction are usually associated with a narrow left ventricular outflow tract. The aim of the present study was to analyse the growth and predictors of future obstruction of the left ventricular outflow tract after surgical repair. We carried out a retrospective review of patients who underwent repair for ventricular septal defect and aortic arch obstruction - coarctation or interrupted aortic arch - between July, 2002 and June, 2013. Echocardiographic data were reviewed, and the need for re-intervention was evaluated. A total of 89 patients were included in this study. A significant left ventricular outflow tract growth was noticed after surgical repair. Preoperatively, the mean left ventricular outflow tract Z-score was -1.46±1 (range -5.5 to 1.1) and increased to a mean value of -0.7±1.3 (range -2.7 to 3.2) at last follow-up (p=0.0001), demonstrating relevant growth of the left ventricular outflow tract after repair for ventricular septal defect and aortic arch obstruction. After primary repair, 11 patients (12.3%) required re-intervention with surgical repair for left ventricular outflow tract obstruction after a mean period of 36±21 months. There were no significant differences in age, weight, and indexed aortic valve and left ventricular outflow tract measurements between those who developed obstruction and those who did not. Significant left ventricular outflow tract growth is expected after repair of ventricular septal defect and aortic arch obstruction. Small aortic valve and left ventricular outflow tract at diagnosis are not risk factors to predict the need for surgical re-intervention for left ventricular outflow tract obstruction in future.
The overloaded right heart and ventricular interdependence.
Naeije, Robert; Badagliacca, Roberto
2017-10-01
The right and the left ventricle are interdependent as both structures are nested within the pericardium, have the septum in common and are encircled with common myocardial fibres. Therefore, right ventricular volume or pressure overloading affects left ventricular function, and this in turn may affect the right ventricle. In normal subjects at rest, right ventricular function has negligible interaction with left ventricular function. However, the right ventricle contributes significantly to the normal cardiac output response to exercise. In patients with right ventricular volume overload without pulmonary hypertension, left ventricular diastolic compliance is decreased and ejection fraction depressed but without intrinsic alteration in contractility. In patients with right ventricular pressure overload, left ventricular compliance is decreased with initial preservation of left ventricular ejection fraction, but with eventual left ventricular atrophic remodelling and altered systolic function. Breathing affects ventricular interdependence, in healthy subjects during exercise and in patients with lung diseases and altered respiratory system mechanics. Inspiration increases right ventricular volumes and decreases left ventricular volumes. Expiration decreases both right and left ventricular volumes. The presence of an intact pericardium enhances ventricular diastolic interdependence but has negligible effect on ventricular systolic interdependence. On the other hand, systolic interdependence is enhanced by a stiff right ventricular free wall, and decreased by a stiff septum. Recent imaging studies have shown that both diastolic and systolic ventricular interactions are negatively affected by right ventricular regional inhomogeneity and prolongation of contraction, which occur along with an increase in pulmonary artery pressure. The clinical relevance of these observations is being explored. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.
Computational Flow Analysis of a Left Ventricular Assist Device
NASA Technical Reports Server (NTRS)
Kiris, Cetin; Kwak, Dochan; Benkowski, Robert
1995-01-01
Computational fluid dynamics has been developed to a level where it has become an Indispensable part of aerospace research and design. Technology developed foe aerospace applications am also be utilized for the benefit of human health. For example, a flange-to-flange rocket engine fuel-pump simulation includes the rotating and non-rotating components: the flow straighteners, the impeller, and diffusers A Ventricular Assist Device developed by NASA Johnson Space Center and Baylor College of Medicine has a design similar to a rocket engine fuel pump in that it also consists of a flow straightener, an impeller, and a diffuser. Accurate and detailed knowledge of the flowfield obtained by incompressible flow calculations can be greatly beneficial to designers in their effort to reduce the cost and improve the reliability of these devices. In addition to the geometric complexities, a variety of flow phenomena are encountered in biofluids Then include turbulent boundary layer separation, wakes, transition, tip vortex resolution, three-dimensional effects, and Reynolds number effects. In order to increase the role of Computational Fluid Dynamics (CFD) in the design process the CFD analysis tools must be evaluated and validated so that designers gain Confidence in their use. The incompressible flow solver, INS3D, has been applied to flow inside of a liquid rocket engine turbopump components and extensively validated. This paper details how the computational flow simulation capability developed for liquid rocket engine pump component analysis has bean applied to the Left Ventricular Assist Device being developed jointly by NASA JSC and Baylor College of Medicine.
Left ventricular filling under elevated left atrial pressure
NASA Astrophysics Data System (ADS)
Gaddam, Manikantam; Samaee, Milad; Santhanakrishnan, Arvind
2017-11-01
Left atrial pressure (LAP) is elevated in diastolic dysfunction, where left ventricular (LV) filling is impaired due to increase in ventricular stiffness. The impact of increasing LAP and LV stiffness on intraventricular filling hemodynamics remains unclear. We conducted particle image velocimetry and hemodynamics measurements in a left heart simulator (LHS) under increasing LAP and LV stiffness at a heart rate of 70 bpm. The LHS consisted of a flexible-walled LV physical model fitted within a fluid-filled chamber. LV wall motion was generated by a piston pump that imparted pressure fluctuations in the chamber. Resistance and compliance elements in the flow loop were adjusted to obtain bulk physiological hemodynamics in the least stiff LV model. Two LV models of increasing stiffness were subsequently tested under unchanged loop settings. LAP was varied between 5-20 mm Hg for each LV model, by adjusting fluid level in a reservoir upstream of the LV. For constant LV stiffness, increasing LAP lowered cardiac output (CO), while ejection fraction (EF) and E/A ratio were increased. For constant LAP, increasing LV stiffness lowered CO and EF, and increased E/A ratio. The implications of these altered hemodynamics on intraventricular filling vortex characteristics will be presented.
Doppler-guided retrograde catheterization system
NASA Astrophysics Data System (ADS)
Frazin, Leon J.; Vonesh, Michael J.; Chandran, Krishnan B.; Khasho, Fouad; Lanza, George M.; Talano, James V.; McPherson, David D.
1991-05-01
The purpose of this study was to investigate a Doppler guided catheterization system as an adjunctive or alternative methodology to overcome the disadvantages of left heart catheterization and angiography. These disadvantages include the biological effects of radiation and the toxic and volume effects of iodine contrast. Doppler retrograde guidance uses a 20 MHz circular pulsed Doppler crystal incorporated into the tip of a triple lumen multipurpose catheter and is advanced retrogradely using the directional flow information provided by the Doppler waveform. The velocity detection limits are either 1 m/second or 4 m/second depending upon the instrumentation. In a physiologic flow model of the human aortic arch, multiple data points revealed a positive wave form when flow was traveling toward the catheter tip indicating proper alignment for retrograde advancement. There was a negative wave form when flow was traveling away from the catheter tip if the catheter was in a branch or bent upon itself indicating improper catheter tip position for retrograde advancement. In a series of six dogs, the catheter was able to be accurately advanced from the femoral artery to the left ventricular chamber under Doppler signal guidance without the use of x-ray. The potential applications of a Doppler guided retrograde catheterization system include decreasing time requirements and allowing safer catheter guidance in patients with atherosclerotic vascular disease and suspected aortic dissection. The Doppler system may allow left ventricular pressure monitoring in the intensive care unit without the need for x-ray and it may allow left sided contrast echocardiography. With pulse velocity detection limits of 4 m/second, this system may allow catheter direction and passage into the aortic root and left ventricle in patients with aortic stenosis. A modification of the Doppler catheter may include transponder technology which would allow precise catheter tip localization once the catheter tip is placed in the aortic root. Such technology may conceivably assist in allowing selective coronary catheterization. These studies have demonstrated that Doppler guided retrograde catheterization provides an accurate method to catheterization the aortic root and left ventricular chamber without x-ray. In humans, it may prove useful in a variety of settings including the development of invasive ultrasonic diagnostic and therapeutic technology.
Sacco, Federica; Paun, Bruno; Lehmkuhl, Oriol; Iles, Tinen L.; Iaizzo, Paul A.; Houzeaux, Guillaume; Vázquez, Mariano; Butakoff, Constantine; Aguado-Sierra, Jazmin
2018-01-01
The aim of the present study is to characterize the hemodynamics of left ventricular (LV) geometries to examine the impact of trabeculae and papillary muscles (PMs) on blood flow using high performance computing (HPC). Five pairs of detailed and smoothed LV endocardium models were reconstructed from high-resolution magnetic resonance images (MRI) of ex-vivo human hearts. The detailed model of one LV pair is characterized only by the PMs and few big trabeculae, to represent state of art level of endocardial detail. The other four detailed models obtained include instead endocardial structures measuring ≥1 mm2 in cross-sectional area. The geometrical characterizations were done using computational fluid dynamics (CFD) simulations with rigid walls and both constant and transient flow inputs on the detailed and smoothed models for comparison. These simulations do not represent a clinical or physiological scenario, but a characterization of the interaction of endocardial structures with blood flow. Steady flow simulations were employed to quantify the pressure drop between the inlet and the outlet of the LVs and the wall shear stress (WSS). Coherent structures were analyzed using the Q-criterion for both constant and transient flow inputs. Our results show that trabeculae and PMs increase the intra-ventricular pressure drop, reduce the WSS and disrupt the dominant single vortex, usually present in the smoothed-endocardium models, generating secondary small vortices. Given that obtaining high resolution anatomical detail is challenging in-vivo, we propose that the effect of trabeculations can be incorporated into smoothed ventricular geometries by adding a porous layer along the LV endocardial wall. Results show that a porous layer of a thickness of 1.2·10−2 m with a porosity of 20 kg/m2 on the smoothed-endocardium ventricle models approximates the pressure drops, vorticities and WSS observed in the detailed models. PMID:29760665
Loforte, Antonio; Montalto, Andrea; Musumeci, Francesco; Amarelli, Cristiano; Mariani, Carlo; Polizzi, Vincenzo; Lilla Della Monica, Paola; Grigioni, Francesco; Di Bartolomeo, Roberto; Marinelli, Giuseppe
2018-05-08
Right ventricular failure after continuous-flow left ventricular assist device (LVAD) implantation is still an unsolved issue and remains a life-threatening event for patients. We undertook this study to determine predictors of the patients who are candidates for isolated LVAD therapy as opposed to biventricular support (BVAD). We reviewed demographic, echocardiographic, hemodynamic, and laboratory variables for 258 patients who underwent both isolated LVAD implantation and unplanned BVAD because of early right ventricular failure after LVAD insertion, between 2006 and 2017 (LVAD = 170 and BVAD = 88). The final study patients were randomly divided into derivation (79.8%, n = 206) and validation (20.1%, n = 52) cohorts. Fifty-seven preoperative risk factors were compared between patients who were successfully managed with an LVAD and those who required a BVAD. Nineteen variables demonstrated statistical significance on univariable analysis. Multivariable logistic regression analysis identified destination therapy (odds ratio [OR] 2.0 [1.7-3.9], p = 0.003), a pulmonary artery pulsatility index <2 (OR 3.3 [1.7-6.1], p = 0.001), a right ventricle/left ventricle end-diastolic diameter ratio >0.75 (OR 2.7 [1.5-5.5], p = 0.001), an right ventricle stroke work index <300 mm Hg/ml/m (OR 4.3 [2.5-7.3], p < 0.001), and a United Network for Organ Sharing modified Model for End-Stage Liver Disease Excluding INR score >17 (OR 3.5 [1.9-6.9], p < 0.001) as the major predictors of the need for BVAD. Using these data, we propose a simple risk calculator to determine the suitability of patients for isolated LVAD support in the era of continuous-flow mechanical circulatory support devices.
Left ventricular function in relation to chronic residential air pollution in a general population
Yang, Wen-Yi; Zhang, Zhen-Yu; Thijs, Lutgarde; Bijnens, Esmée M; Janssen, Bram G; Vanpoucke, Charlotte; Lefebvre, Wouter; Cauwenberghs, Nicholas; Wei, Fang-Fei; Luttun, Aernout; Verhamme, Peter; Van Hecke, Etienne; Kuznetsova, Tatiana; D’hooge, Jan; Nawrot, Tim S
2017-01-01
Background In view of the increasing heart failure epidemic and awareness of the adverse impact of environmental pollution on human health, we investigated the association of left ventricular structure and function with air pollutants in a general population. Methods In 671 randomly recruited Flemish (51.7% women; mean age, 50.4 years) we echocardiographically assessed left ventricular systolic strain and strain rate and the early and late peak velocities of transmitral blood flow and mitral annular movement (2005−2009). Using subject-level data, left ventricular function was cross-sectionally correlated with residential long-term exposure to air pollutants, including black carbon, PM2.5, PM10 (particulate matter) and nitrogen dioxide (NO2), while accounting for clustering by residential address and confounders. Results Annual exposures to black carbon, PM2.5, PM10 and NO2 averaged 1.19, 13.0, 17.7, and 16.8 µg/m3. Systolic left ventricular function was worse (p ≤ 0.027) with higher black carbon, PM2.5, PM10 and NO2 with association sizes per interquartile interval increment ranging from −0.339 to −0.458% for longitudinal strain and from −0.033 to −0.049 s−1 for longitudinal strain rate. Mitral E and a′ peak velocities were lower (p ≤ 0.021) with higher black carbon, PM2.5 and PM10 with association sizes ranging from −1.727 to −1.947 cm/s and from −0.175 to −0.235 cm/s, respectively. In the geographic analysis, the systolic longitudinal strain sided with gradients in air pollution. The path analysis identified systemic inflammation as a possible mediator of associations with black carbon. Conclusions Long-term low-level air pollution is associated with subclinical impairment of left ventricular performance and might be a risk factor for heart failure. PMID:28617090
Parratt, J R; Winslow, E
1971-06-01
1. The effects of intravenous infusions of quazodine (6,7-dimethoxy-4-ethylquinazoline; MJ-1988) on myocardial blood flow, myocardial metabolic heat production and on general haemodynamics have been studied in cats anaesthetized with sodium pentobarbitone.2. Quazodine (0.25 and 0.5 (mg/kg)/min for 10 min) decreased diastolic blood pressure, peripheral vascular resistance, systolic ejection time and left ventricular end-diastolic pressure. Heart rate, cardiac effort, output and external work and left ventricular dP/dt were markedly increased. These changes are indicative of increased myocardial contractility and peripheral vasodilatation.3. In a dose of (1.0 mg/kg)/min, quazodine had a more marked hypotensive effect, systolic pressure being significantly reduced, and had less effect on left ventricular dP/dt and cardiac effort. Calculated external cardiac work was slightly reduced and there were very occasional nodal arrhythmias.4. Changes in heart rate, aortic dP/dt and diastolic blood pressure induced by quazodine were unaffected by the previous administration of the beta-adrenoceptor blocking agent alprenolol in a dose (1.0 mg/kg) which abolished the effects of isoprenaline.5. In all doses, quazodine markedly increased local blood flow (by 70-540%) around an implanted myocardial heated thermocouple recorder. ;Corrected temperature', an index of local myocardial metabolic heat production, was almost unchanged and it is suggested that increased myocardial contractility, occurring with unchanged metabolic heat production and oxygen consumption, probably results from a concomitant decrease in intramural wall tension.
Lietz, Katherine; Brown, Kevin; Ali, Syed S; Colvin-Adams, Monica; Boyle, Andrew J; Anderson, David; Weinberg, Alan D; Miller, Leslie W; Park, Soon; John, Ranjit; Lazar, Ronald M
2009-04-01
Cerebral hyperperfusion is a life-threatening syndrome that can occur in patients with chronically hypoperfused cerebral vasculature whose normal cerebral circulation was re-established after carotid endarterectomy or angioplasty. We sought to determine whether the abrupt restoration of perfusion to the brain after left ventricular assist device (LVAD) implantation produced similar syndromes. We studied the role of increased systemic flow after LVAD implantation on neurologic dysfunction in 69 consecutive HeartMate XVE LVAD (Thoratec, Pleasanton, Calif) recipients from October 2001 through June 2006. Neurologic dysfunction was defined as postoperative permanent or transient central change in neurologic status, including confusion, focal neurologic deficits, visual changes, seizures, or coma for more than 24 hours within 30 days after LVAD implantation. We found that 19 (27.5%) patients had neurologic dysfunction, including encephalopathy (n = 11), coma (n = 3), and other complications (n = 5). The multivariate analysis showed that an increase in cardiac index from the preoperative baseline value (relative risk, 1.33 per 25% cardiac index increase; P = .01) and a previous coronary bypass operation (relative risk, 4.53; P = .02) were the only independent predictors of neurologic dysfunction. Reduction of left ventricular assist device flow in 16 of the 19 symptomatic patients led to improvement of symptoms in 14 (87%) patients. Our findings showed that normal flow might overwhelm cerebral autoregulation in patients with severe heart failure, suggesting that cerebral hyperperfusion is possible in recipients of mechanical circulatory support with neurologic dysfunction.
Clinical determinants and consequences of left ventricular hypertrophy.
Messerli, F H
1983-09-26
The left ventricle adapts to an increased afterload such as that produced by arterial hypertension with concentric left ventricular hypertrophy. However, this adaptive process can be modified by a variety of physiologic and pathophysiologic states. Progressive aging, black race, and perhaps disorders with an increased sympathetic outflow seem to accelerate left ventricular hypertrophy. Obesity and other high cardiac output states predominantly produce dilatation of the left ventricle, and their combination with arterial hypertension results in eccentric left ventricular hypertrophy. Similarly, endurance exercise increases left ventricular volume more than wall thickness, whereas isometric exercise produces an increase in wall thickness only. The presence or absence of some physiologic and pathogenetic factors has direct implication on the assessment of what constitutes a "normal" left ventricular structure and function. Left ventricular hypertrophy has been shown to increase ventricular ectopic impulse generation and to put patients at a high risk of sudden death. Moreover, the increase in myocardial mass lowers coronary reserve and enhances cardiac oxygen requirements. Thus, the presence of left ventricular hypertrophy has to be considered as an ominous sign rather than as a benign adaptive process.
Dini, Frank L; Guarini, Giacinta; Ballo, Piercarlo; Carluccio, Erberto; Maiello, Maria; Capozza, Paola; Innelli, Pasquale; Rosa, Gian M; Palmiero, Pasquale; Galderisi, Maurizio; Razzolini, Renato; Nodari, Savina
2013-03-01
The interpretation of the heart as a mechanical engine dates back to the teachings of Leonardo da Vinci, who was the first to apply the laws of mechanics to the function of the heart. Similar to any mechanical engine, whose performance is proportional to the power generated with respect to weight, the left ventricle can be viewed as a power generator whose performance can be related to left ventricular mass. Stress echocardiography may provide valuable information on the relationship between cardiac performance and recruited left ventricular mass that may be used in distinguishing between adaptive and maladaptive left ventricular remodeling. Peak power output-to-mass, obtained during exercise or pharmacological stress echocardiography, is a measure that reflects the number of watts that are developed by 100 g of left ventricular mass under maximal stimulation. Power output-to-mass may be calculated as left ventricular power output per 100 g of left ventricular mass: 100× left ventricular power output divided by left ventricular mass (W/100 g). A simplified formula to calculate power output-to-mass is as follows: 0.222 × cardiac output (l/min) × mean blood pressure (mmHg)/left ventricular mass (g). When the integrity of myocardial structure is compromised, a mismatch becomes apparent between maximal cardiac power output and left ventricular mass; when this occurs, a reduction of the peak power output-to-mass index is observed.
Pediatric experience with the VentrAssist LVAD.
Ruygrok, Peter N; Esmore, Don S; Alison, Peter M; Finucane, Kirsten A; McGuinness, Shay P; McGeorge, Alastair D; Negri, Justin; Jones, Kylie; Gibbs, Helen C
2008-08-01
The purpose of this study is to describe the first experience of implanting a new left ventricular assist device in pediatric patients with end-stage heart failure. In two recent prospective, international, multicenter clinical trials, three children (aged = 16 years) were implanted successfully with the VentrAssist (Ventracor Limited, Chatswood, Australia), a relatively small, novel, continuous flow, third-generation left ventricular assist device. Despite the patients' disease severity (each child was in extremis at the time of implantation), VentrAssist (Ventracor Limited) implantation enabled each patient to be discharged home from the hospital. All patients survived for more than 1 year. One patient was successfully transplanted and another was bridged to an adequate degree of recovery; unfortunately, the third patient died on postoperative day 375 while waiting for a suitable donor heart. Consistent with the complications associated with left ventricular assist devices in adults, the main complications in these pediatric patients were infection and thromboembolism. The VentrAssist may provide a major advancement in the management of larger children and adolescents with end-stage heart failure.
Fukushima, Norihide; Tatsumi, Eisuke; Seguchi, Osamu; Takewa, Yoshiaki; Hamasaki, Toshimitsu; Onda, Kaori; Yamamoto, Haruko; Hayashi, Teruyuki; Fujita, Tomoyuki; Kobayashi, Junjiro
2018-06-08
The management of heart failure patients presenting in a moribund state remains challenging, despite significant advances in the field of ventricular assist systems. Bridge to decision involves using temporary devices to stabilize the hemodynamic state of such patients while further assessment is performed and a decision can be made regarding patient management. The purpose of this study (NCVC-BTD_01, National Cerebral and Cardiovascular Center-Bridge to Dicision_01) is to assess the safety and effectiveness of the newly developed extracorporeal continuous-flow ventricular assist system employing a disposable centrifugal pump with a hydrodynamically levitated bearing (BR16010) use as a bridge-to-decision therapy for patients with severe heart failure or refractory cardiogenic shock. NCVC-BTD_01 is a single-center, single-arm, open-label, exploratory, medical device, investigator-initiated clinical study. It is conducted at the National Cerebral and Cardiovascular Center in Japan. A total of nine patients will be enrolled in the study. The study was planned using Simon's minimax two-stage phase design. The primary endpoint is a composite of survival free of device-related serious adverse events and complications during device support. For left ventricular assistance, withdrawal of a trial device due to cardiac function recovery or exchange to other ventricular assist devices (VADs) for the purpose of bridge to transplantation (BTT) during 30 days after implantation will be considered study successes. For right ventricular assistance, withdrawal of tal device due to right ventricular function recovery within 30 days after implantation will be considered a study success. Secondary objectives include changes in brain natriuretic peptide levels (7 days after implantation of a trial device and the day of withdrawal of a trial device), period of mechanical ventricular support, changes in left ventricular ejection fraction (7 days after implantation of a trial device and the day of withdrawal of a trial device), and changes in left ventricular diastolic dimension (7 days after implantation of a trial device and the day of withdrawal of a trial device). We will disseminate the findings through regional, national, and international conferences and through peer-reviewed journals. UMIN Clinical Trials Registry (UMIN-CTR; R000033243) registered on 8 September 2017.
Cho, In-Jeong; Shim, Chi Young; Moon, Sun-Ha; Lee, Hyun-Jin; Hong, Geu-Ru; Chung, Namsik; Ha, Jong-Won
2017-05-01
The shape and duration of left ventricular outflow tract (LVOT) flow has not been applied to assess the central haemodynamics, although LVOT flow is confronted with afterload of arterial system during systole. The aim of this study was to evaluate whether the LVOT flow parameters are related with central systolic blood pressure (BP) and arterial compliance at rest and as well as during exercise. We studied 258 subjects (175 females, age 61 ± 11 years) with normal left ventricular (LV) systolic function who underwent supine bicycle stress echocardiography and arterial tonometry simultaneously at rest and at peak exercise. Deceleration time (DT) of LVOT flow and RR interval were measured and deceleration time corrected for heart rate (DTc) was calculated. Peripheral and central haemodynamic parameters including systolic and diastolic BP, and augmentation index at a heart rate of 75 (AIx@75) were assessed using radial artery tonometry. Carotid femoral pulse wave velocity (PWV) was measured. Deceleration time corrected for heart rate was independently associated with central systolic BP and AIx@75 at rest (P < 0.001 and 0.006). Similarly, it also showed significant independent correlations with central systolic BP and AIx@75 during peak exercise (P = 0.006 and P = 0.021). In addition, DTc which measured both at rest and at peak exercise demonstrated significant positive correlations with PWV, suggesting association of prolonged DTc with arterial stiffening (P = 0.023 and P = 0.005). Prolongation of LVOT flow DTc represents raised central systolic BP and increased arterial stiffness not only at rest but also during exercise. Therefore, central aortic pressures and arterial stiffness influence the DT of LVOT flow at rest as well as during exercise in individuals with normal LV systolic function. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.
Reindl, Martin; Feistritzer, Hans-Josef; Reinstadler, Sebastian Johannes; Mueller, Lukas; Tiller, Christina; Brenner, Christoph; Mayr, Agnes; Henninger, Benjamin; Mair, Johannes; Klug, Gert; Metzler, Bernhard
2018-04-01
Adverse left ventricular remodeling is one of the major determinants of heart failure and mortality in patients surviving ST-segment elevation myocardial infarction (STEMI). The hypothalamic-pituitary-thyroid axis is a key cardiovascular regulator; however, the relationship between hypothalamic-pituitary-thyroid status and post-STEMI left ventricular remodeling is unclear. We aimed to investigate the association between thyroid-stimulating hormone concentrations and the development of left ventricular remodeling following reperfused STEMI. In this prospective observational study of 102 consecutive STEMI patients, thyroid-stimulating hormone levels were measured at the first day after infarction and 4 months thereafter. Cardiac magnetic resonance scans were performed within the first week as well as at 4 months follow-up to determine infarct characteristics, myocardial function and as primary endpoint left ventricular remodeling, defined as a 20% or greater increase in left ventricular end-diastolic volume. Patients with left ventricular remodeling ( n=15, 15%) showed significantly lower concentrations of baseline (1.20 [0.92-1.91] vs. 1.73 [1.30-2.60] mU/l; P=0.02) and follow-up (1.11 [0.86-1.28] vs. 1.51 [1.15-2.02] mU/l; P=0.002) thyroid-stimulating hormone. The association between baseline thyroid-stimulating hormone and left ventricular remodeling remained significant after adjustment for major clinical (peak high-sensitivity cardiac troponin T and C-reactive protein, heart rate; odds ratio (OR) 5.33, 95% confidence interval (CI) 1.52-18.63; P=0.01) and cardiac magnetic resonance predictors of left ventricular remodeling (infarct size, microvascular obstruction, ejection fraction; OR 4.59, 95% CI 1.36-15.55; P=0.01). Furthermore, chronic thyroid-stimulating hormone was related to left ventricular remodeling independently of chronic left ventricular remodeling correlates (infarct size, ejection fraction, left ventricular end-diastolic volume, left ventricular end-systolic volume; OR 9.22, 95% CI 1.69-50.22; P=0.01). Baseline and chronic thyroid-stimulating hormone concentrations following STEMI were independently associated with left ventricular remodeling, proposing a novel pathophysiological axis in the development of post-STEMI left ventricular remodeling.
NASA Astrophysics Data System (ADS)
Miramontes, Marissa; Rossini, Lorenzo; Braun, Oscar; Brambatti, Michela; Almeida, Shone; Mizeracki, Adam; Martinez-Legazpi, Pablo; Benito, Yolanda; Bermejo, Javier; Kahn, Andrew; Adler, Eric; Del Álamo, Juan C.
2017-11-01
In heart failure patients, left ventricular (LV) assist devices (LVADs) decrease mortality and improve quality of life. We hypothesize echo color Doppler velocimetry (echo-CDV), an echocardiographic flow mapping modality, can non-invasively characterize the effect of LVAD support, optimize the device, thereby decreasing the stoke rate present in these patients. We used echo-CDV to image LV flow at baseline LVAD speed and during a ramp test in LVAD patients (Heartmate II, N =10). We tracked diastolic vortices and mapped blood stasis and cumulative shear. Compared to dilated cardiomyopathy (DCM) patients without LVADs, the flow had a less prominent diastolic vortex ring, and transited directly from mitral valve to cannula. Residence time and shear were significantly lower compared to healthy controls and DCMs. Aortic regurgitation and a large LV vortex presence or a direct mitral jet towards the cannula affected blood stasis region location and size. Flow patterns, residence time and shear depended on LV geometry, valve function and LVAD speed in a patient specific manner. This new methodology could be used with standard echo, hemodynamics and clinical information to find the flow optimizing LAVD setting minimizing stasis for each patient.
Nordmeyer, Sarah; Schmitt, Boris; Nasseri, Boris; Alexi-Meskishvili, Vladimir; Kuehne, Titus; Berger, Felix; Nordmeyer, Johannes
2018-02-01
We sought to assess left ventricular regional function in patients with and without left ventricular wall scar tissue in the long term after repair of an anomalous origin of the left coronary artery from the pulmonary artery. A total of 20 patients aged 12.8±7.4 years were assessed 10 (0.5-17) years after the repair of an anomalous origin of the left coronary artery from the pulmonary artery; of them, 10 (50%) patients showed left ventricular wall scar tissue on current cardiac MRI. Left ventricular regional function was assessed by two-dimensional speckle-tracking echocardiography in 10 patients with scar tissue and 10 patients without scar tissue and in 10 age-matched controls. In patients with scar tissue, MRI-derived left ventricular ejection fraction was significantly reduced compared with that in patients without scar tissue (51 versus 61%, p<0.05), and echocardiography-derived longitudinal strain was significantly reduced in five of six left ventricular areas compared with that in healthy controls (average relative reduction, 46%; p<0.05). In patients without scar tissue, longitudinal strain was significantly reduced in two of six left ventricular areas (average relative reduction, 23%; p<0.05) and circumferential strain was reduced in one of six left ventricular areas (relative reduction, 56%; p<0.05) compared with that in healthy controls. Regional left ventricular function is reduced even in patients without left ventricular wall scar tissue late after successful repair of an anomalous origin of the left coronary artery from the pulmonary artery. This highlights the need for meticulous lifelong follow-up in all patients with a repaired anomalous origin of the left coronary artery from the pulmonary artery.
NASA Technical Reports Server (NTRS)
Steele, P.; Kirch, D.
1975-01-01
In 47 men with arteriographically defined coronary artery disease comparative studies of left ventricular ejection fraction and segmental wall motion were made with radionuclide data obtained from the image intensifier camera computer system and with contrast cineventriculography. The radionuclide data was digitized and the images corresponding to left ventricular end-diastole and end-systole were identified from the left ventricular time-activity curve. The left ventricular end-diastolic and end-systolic images were subtracted to form a silhouette difference image which described wall motion of the anterior and inferior left ventricular segments. The image intensifier camera allows manipulation of dynamically acquired radionuclide data because of the high count rate and consequently improved resolution of the left ventricular image.
Kim, Tae Hoon; Shin, Yu Rim; Kim, Young Sam; Kim, Do Jung; Kim, Hyohyun; Shin, Hong Ju; Htut, Aung Thein; Park, Han Ki
2015-12-01
A two-month-old infant presented with coarctation of the aorta, severe left ventricular dysfunction, and moderate to severe mitral regurgitation. Through median sternotomy, the aortic arch was repaired under cardiopulmonary bypass and regional cerebral perfusion. The patient was postoperatively supported with a left ventricular assist device for five days. Left ventricular function gradually improved, eventually recovering with the concomitant regression of mitral regurgitation. Prompt surgical repair of coarctation of the aorta is indicated for patients with severe left ventricular dysfunction. A central approach for surgical repair with a back-up left ventricular assist device is a safe and effective treatment strategy for these patients.
Concomitant transcatheter aortic valve and left ventricular assist device implantation.
Baum, Christina; Seiffert, Moritz; Treede, Hendrik; Reichenspurner, Hermann; Deuse, Tobias
2013-01-01
Relevant aortic regurgitation (AR) requires surgical repair at the time of left ventricular assist device (LVAD) implantation to reduce recirculation and ensure adequate forward flow. We report here on a patient with moderate AR in a noncalcified aortic valve and extensive calcification of the ascending aorta. The latter precluded aortic-crossclamping and, thus, surgical intervention on the aortic valve. Although there were no valvular or annular calcifications, a JenaValve transcatheter heart valve was successfully placed transapically with subsequent LVAD implantation in one operation. We believe concomitant transcatheter aortic valve implantation (TAVI) and LVAD implantation is a promising hybrid procedure, even in patients with pure AR.
Patterns of left ventricular remodeling among patients with essential and secondary hypertension.
Radulescu, Dan; Stoicescu, Laurentiu; Buzdugan, Elena; Donca, Valer
2013-12-01
High blood pressure causes left ventricular hypertrophy, which is a negative prognostic factor among hypertensive patients. To assess left ventricular geometric remodeling patterns in patients with essential hypertension or with hypertension secondary to parenchymal renal disease. We analyzed data from echocardiograms performed in 250 patients with essential hypertension (150 females) and 100 patients with secondary hypertension (60 females). The interventricular septum and the left ventricular posterior wall thickness were measured in the parasternal long-axis. Left ventricular mass was calculated using the Devereaux formula. The most common remodeling type in females and males with essential hypertension were eccentric and concentric left ventricular hypertrophy (cLVH), respectively. Among patients with secondary arterial hypertension, cLVH was most commonly observed in both genders. The prevalence of left ventricular hypertrophy was higher among patients with secondary hypertension. The left ventricular mass index and the relative left ventricular wall thickness were higher in males and also in the secondary hypertension group. Age, blood pressure values and the duration of hypertension, influenced remodeling patterns. We documented a higher prevalence of LVH among patients with secondary hypertension. The type of ventricular remodeling depends on gender, age, type of hypertension, blood pressure values and the duration of hypertension.
Arrighi, James A; Burg, Matthew; Cohen, Ira S; Soufer, Robert
2003-01-01
Mental stress (MS) is an important provocateur of myocardial ischemia in many patients with chronic coronary artery disease. The majority of laboratory assessments of ischemia in response to MS have included measurements of either myocardial perfusion or function alone. We performed this study to determine the relationship between alterations in perfusion and ventricular function during MS. Methods and results Twenty-eight patients with reversible perfusion defects on exercise or pharmacologic stress myocardial perfusion imaging (MPI) underwent simultaneous technetium 99m sestamibi single photon emission computed tomography (SPECT) MPI and transthoracic echocardiography at rest and during MS according to a mental arithmetic protocol. In all cases the MS study was performed within 4 weeks of the initial exercise or pharmacologic MPI that demonstrated ischemia. SPECT studies were analyzed visually with the use of a 13-segment model and quantitatively by semiautomated circumferential profile analysis. Echocardiograms were graded on a segmental model for regional wall motion on a 4-point scale. Of 28 patients, 18 (64%) had perfusion defects and/or left ventricular dysfunction develop during MS: 9 (32%) had myocardial perfusion defects develop, 6 (21%) had regional or global left ventricular dysfunction develop, and 3 (11%) had both perfusion defects and left ventricular dysfunction develop. The overall concordance between perfusion and function criteria for ischemia during MS was only 46%. Among 9 patients with MS-induced left ventricular dysfunction, 5 had new regional wall motion abnormalities and 4 had a global decrement in function. In patients with MS-induced ischemia by SPECT, the number of reversible perfusion defects was similar during both MS and exercise/pharmacologic stress (2.8 +/- 2.0 vs 3.5 +/- 1.8, P =.41). Hemodynamic changes during MS were similar whether patients were divided on the basis of perfusion defects or left ventricular dysfunction during MS. These data indicate the feasibility of simultaneous assessment of perfusion and function responses during MS. Flow and function responses to MS are frequently not concordant. These data suggest that MS-induced changes in perfusion may represent a different phenomenon than MS-induced changes in left ventricular function (either globally or regionally).
Gregory, Shaun D; Stevens, Michael C; Pauls, Jo P; Schummy, Emma; Diab, Sara; Thomson, Bruce; Anderson, Ben; Tansley, Geoff; Salamonsen, Robert; Fraser, John F; Timms, Daniel
2016-09-01
Preventing ventricular suction and venous congestion through balancing flow rates and circulatory volumes with dual rotary ventricular assist devices (VADs) configured for biventricular support is clinically challenging due to their low preload and high afterload sensitivities relative to the natural heart. This study presents the in vivo evaluation of several physiological control systems, which aim to prevent ventricular suction and venous congestion. The control systems included a sensor-based, master/slave (MS) controller that altered left and right VAD speed based on pressure and flow; a sensor-less compliant inflow cannula (IC), which altered inlet resistance and, therefore, pump flow based on preload; a sensor-less compliant outflow cannula (OC) on the right VAD, which altered outlet resistance and thus pump flow based on afterload; and a combined controller, which incorporated the MS controller, compliant IC, and compliant OC. Each control system was evaluated in vivo under step increases in systemic (SVR ∼1400-2400 dyne/s/cm(5) ) and pulmonary (PVR ∼200-1000 dyne/s/cm(5) ) vascular resistances in four sheep supported by dual rotary VADs in a biventricular assist configuration. Constant speed support was also evaluated for comparison and resulted in suction events during all resistance increases and pulmonary congestion during SVR increases. The MS controller reduced suction events and prevented congestion through an initial sharp reduction in pump flow followed by a gradual return to baseline (5.0 L/min). The compliant IC prevented suction events; however, reduced pump flows and pulmonary congestion were noted during the SVR increase. The compliant OC maintained pump flow close to baseline (5.0 L/min) and prevented suction and congestion during PVR increases. The combined controller responded similarly to the MS controller to prevent suction and congestion events in all cases while providing a backup system in the event of single controller failure. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Myocardial metabolism during exposure to carbon monoxide in the conscious dog.
NASA Technical Reports Server (NTRS)
Adams, J. D.; Erickson, H. H.; Stone, H. L.
1973-01-01
Investigation of the relationship between coronary flow, heart rate, left ventricular function, and myocardial oxygen consumption at increasing levels of carboxyhemoglobin in conscious dogs. The results demonstrate a linear increase in coronary flow and heart rate as the carboxyhemoglobin increases up to 20%. Myocardial oxygen consumption declined during the same period.
Primary angioplasty for infarction due to isolated right ventricular artery occlusion.
Chahal, Anwar A; Kim, Min-Young; Borg, Alexander N; Al-Najjar, Yahya
2014-11-26
We report an unusual case of an isolated right ventricular infarction with haemodynamic compromise caused by spontaneous isolated proximal occlusion of the right ventricular branch of the right coronary artery (RCA), successfully treated by balloon angioplasty. A 58-year-old gentleman presented with epigastric pain radiating into both arms. Electrocardiograph with right ventricular leads confirmed ST elevation in V4R and a diagnosis of isolated right ventricular infarction was made. Urgent primary percutaneous intervention was performed which revealed occlusion of the right ventricular branch of the RCA. During the procedure, the patient's blood pressure dropped to 80/40 mmHg, and echocardiography showed impaired right ventricular systolic function. Despite aggressive fluid resuscitation, the patient remained hypotensive, continued to have chest pain and persistent electrocardiograph changes, and hence balloon angioplasty was performed on the proximal right ventricular branch which restored flow to the vessel and revealed a severe ostial stenosis. This was treated with further balloon angioplasty which restored TIMI 3 flow with resolution of patient's symptoms. Repeat echocardiography showed complete resolution of the ST-elevation in leads V4R and V5R and partial resolution in V1. Subsequent dobutamine-stress echocardiography at 4 wk showed good left and right ventricular contractions. The patient was discharged after a 3-d in-patient stay without any complications.
Schreuder, Jan J; Castiglioni, Alessandro; Maisano, Francesco; Steendijk, Paul; Donelli, Andrea; Baan, Jan; Alfieri, Ottavio
2005-01-01
Surgical left ventricular restoration by means of endoventricular patch aneurysmectomy in patients with postinfarction aneurysm should result in acute improved left ventricular performance by decreasing mechanical dyssynchrony and increasing energy efficiency. Nine patients with left ventricular postinfarction aneurysm were studied intraoperatively before and after ventricular restoration with a conductance volume catheter to analyze pressure-volume relationships, energy efficiency, and mechanical dyssynchrony. The end-systolic elastance was used as a load-independent index of contractile state. Left ventricular energy efficiency was calculated from stroke work and total pressure-volume area. Segmental volume changes perpendicular to the long axis were used to calculate mechanical dyssynchrony. Statistical analysis was performed with the paired t test and least-squares linear regression. Endoventricular patch aneurysmectomy reduced end-diastolic volume by 37% (P < .001), with unchanged stroke volume. Systolic function improved, as derived from increased +dP/dt(max), by 42% (P < .03), peak ejection rate by 28% (P < .02), and ejection fraction by 16% (P < .0002). Early diastolic function improved, as shown by reduction of -dP/dt(max) by 34% (P < .006) and shortened tau by 30% (P < .001). Left ventricular end-systolic elastance increased from 1.2 +/- 0.6 to 2.2 +/- 1 mm Hg/mL (P < .001). Left ventricular energy efficiency increased by 36% (P < .002). Left ventricular mechanical dyssynchrony decreased during systole by 33% (P < .001) and during diastole by 20% (P < .005). Left ventricular restoration induced acute improvements in contractile state, energy efficiency, and relaxation, together with a decrease in left ventricular mechanical dyssynchrony.
Value of right ventricular mapping in patients with postinfarction ventricular tachycardia.
Yokokawa, Miki; Good, Eric; Crawford, Thomas; Chugh, Aman; Pelosi, Frank; Latchamsetty, Rakesh; Oral, Hakan; Morady, Fred; Bogun, Frank
2012-06-01
Postinfarction ventricular tachycardia (VT) typically involves the left ventricular endocardium. Right ventricular involvement in the arrhythmogenic substrate of postinfarction VT is considered unusual. To assess the role of right ventricular mapping and ablation in patients with prior septal myocardial infarction. From among 37 consecutive patients with recurrent postinfarction VT, 18 patients with evidence of left ventricular septal involvement of myocardial infarction were identified; these patients were the subjects of this report. In these 18 patients, 166 VTs (cycle length 372 ± 117 ms) were induced. Right ventricular voltage mapping was performed in all 18 patients with left ventricular septal myocardial infarction. Right ventricular voltage mapping showed areas of low voltage in 11 patients; pace mapping from these areas revealed matching pace maps for 17 VTs, and radiofrequency ablation from the right ventricular endocardium but not the left ventricular endocardium eliminated 14 of 17 VTs. VTs with critical components in the right ventricle had a left bundle branch block morphology that had similar characteristics as left bundle branch block VTs with critical areas involving the left ventricular septum. Patients with right ventricular VT breakthrough sites had a lower ejection fraction than did patients without VT breaking out on the right ventricular septum (18% ± 5% vs 33% ± 15%; P = .01). Right ventricular mapping and ablation may be necessary in order to eliminate all inducible VTs in patients with postinfarction VT. More than half the patients with septal myocardial infarction have right ventricular septal areas that are critical for postinfarction VT and that cannot be eliminated by left ventricular ablation alone. Copyright © 2012 Heart Rhythm Society. All rights reserved.
Zhuang, Lei; Wang, Xin-Fang; Xie, Ming-Xing; Chen, Li-Xin; Fei, Hong-Wen; Yang, Ying; Wang, Jing; Huang, Run-Qing; Chen, Ou-Di; Wang, Liang-Yu
2004-01-01
To evaluate the feasibility and accuracy of measurement of left ventricular mass with intravenous contrast enhanced real-time three-dimensional (RT3D) echocardiography in the experimental setting. RT3D echocardiography was performed in 13 open-chest mongrel dogs before and after intravenous infusion of a perfluorocarbon contrast agent. Left ventricular myocardium volume was measured according to the apical four-plane method provided by TomTec 4D cardio-View RT1.0 software, then the left ventricular mass was calculated as the myocardial volume multiplied by the relative density of myocardium. Correlative analysis and paired t-test were performed between left ventricular mass obtained from RT3D echocardiography and the anatomic measurements. Anatomic measurement of total left ventricular mass was 55.6 +/- 9.3 g, whereas RT3D echocardiographic calculation of left ventricular mass before and after intravenous perfluorocarbon contrast agent was 57.5 +/- 11.4 and 55.5 +/- 9.3 g, respectively. A significant correlation was observed between the RT3D echocardiographic estimates of total left ventricular mass and the corresponding anatomic measurements (r = 0.95). A strong correlation was found between RT3D echocardiographic estimates of left ventricular mass with perfluorocarbon contrast and the anatomic results (r = 0.99). Analysis of intraobserver and interobserver variability showed strong indexes of agreement in the measurement of left ventricular mass with pre and post-contrast RT3D echocardiography. Measurements of left ventricular mass derived from RT3D echocardiography with and without intravenous contrast showed a significant correlation with the anatomic results. Contrast enhanced RT3D echocardiography permitted better visualization of the endocardial border, which would provide a more accurate and reliable means of determining left ventricular myocardial mass in the experimental setting.
Brain Emboli After Left Ventricular Endocardial Ablation.
Whitman, Isaac R; Gladstone, Rachel A; Badhwar, Nitish; Hsia, Henry H; Lee, Byron K; Josephson, S Andrew; Meisel, Karl M; Dillon, William P; Hess, Christopher P; Gerstenfeld, Edward P; Marcus, Gregory M
2017-02-28
Catheter ablation for ventricular tachycardia and premature ventricular complexes (PVCs) is common. Catheter ablation of atrial fibrillation is associated with a risk of cerebral emboli attributed to cardioversions and numerous ablation lesions in the low-flow left atrium, but cerebral embolic risk in ventricular ablation has not been evaluated. We enrolled 18 consecutive patients meeting study criteria scheduled for ventricular tachycardia or PVC ablation over a 9-month period. Patients undergoing left ventricular (LV) ablation were compared with a control group of those undergoing right ventricular ablation only. Patients were excluded if they had implantable cardioverter defibrillators or permanent pacemakers. Radiofrequency energy was used for ablation in all cases and heparin was administered with goal-activated clotting times of 300 to 400 seconds for all LV procedures. Pre- and postprocedural brain MRI was performed on each patient within a week of the ablation procedure. Embolic infarcts were defined as new foci of reduced diffusion and high signal intensity on fluid-attenuated inversion recovery brain MRI within a vascular distribution. The mean age was 58 years, half of the patients were men, half had a history of hypertension, and the majority had no known vascular disease or heart failure. LV ablation was performed in 12 patients (ventricular tachycardia, n=2; PVC, n=10) and right ventricular ablation was performed exclusively in 6 patients (ventricular tachycardia, n=1; PVC, n=5). Seven patients (58%) undergoing LV ablation experienced a total of 16 cerebral emboli, in comparison with zero patients undergoing right ventricular ablation ( P =0.04). Seven of 11 patients (63%) undergoing a retrograde approach to the LV developed at least 1 new brain lesion. More than half of patients undergoing routine LV ablation procedures (predominately PVC ablations) experienced new brain emboli after the procedure. Future research is critical to understanding the long-term consequences of these lesions and to determining optimal strategies to avoid them. © 2017 American Heart Association, Inc.
Marui, Akira; Nishina, Takeshi; Saji, Yoshiaki; Yamazaki, Kazuhiro; Shimamoto, Takeshi; Ikeda, Tadashi; Sakata, Ryuzo
2010-05-01
Surgical ventricular restoration (SVR) has been introduced to restore the dilated left ventricular (LV) chamber and improve LV systolic function; however, SVR has also been reported to detrimentally affect LV diastolic properties. We sought to investigate the impact of preoperative LV diastolic function on outcomes after SVR in patients with heart failure. Sixty-seven patients (60 +/- 14 years) with LV systolic dysfunction (LV ejection fraction, 0.27 +/- 0.10) underwent SVR. They were evaluated by echocardiography preoperatively, and early (
Cardiac changes induced by immersion and breath-hold diving in humans.
Marabotti, Claudio; Scalzini, Alessandro; Cialoni, Danilo; Passera, Mirko; L'Abbate, Antonio; Bedini, Remo
2009-01-01
To evaluate the separate cardiovascular response to body immersion and increased environmental pressure during diving, 12 healthy male subjects (mean age 35.2 +/- 6.5 yr) underwent two-dimensional Doppler echocardiography in five different conditions: out of water (basal); head-out immersion while breathing (condition A); fully immersed at the surface while breathing (condition B) and breath holding (condition C); and breath-hold diving at 5-m depth (condition D). Heart rate, left ventricular volumes, stroke volume, and cardiac output were obtained by underwater echocardiography. Early (E) and late (A) transmitral flow velocities, their ratio (E/A), and deceleration time of E (DTE) were also obtained from pulsed-wave Doppler, as left ventricular diastolic function indexes. The experimental protocol induced significant reductions in left ventricular volumes, left ventricular stroke volume (P < 0.05), cardiac output (P < 0.001), and heart rate (P < 0.05). A significant increase in E peak (P < 0.01) and E/A (P < 0.01) and a significant reduction of DTE (P < 0.01) were also observed. Changes occurring during diving (condition D) accounted for most of the changes observed in the experimental series. In particular, cardiac output at condition D was significantly lower compared with each of the other experimental conditions, E/A was significantly higher during condition D than in conditions A and C. Finally, DTE was significantly shorter at condition D than in basal and condition C. This study confirms a reduction of cardiac output in diving humans. Since most of the changes were observed during diving, the increased environmental pressure seems responsible for this hemodynamic rearrangement. Left ventricular diastolic function changes suggest a constrictive effect on the heart, possibly accounting for cardiac output reduction.
Diastolic function of the nonfilling human left ventricle.
Paulus, W J; Vantrimpont, P J; Rousseau, M F
1992-12-01
To investigate an early-diastolic left ventricular suction effect in humans, tip-micromanometer left ventricular pressure recordings were obtained in patients with mitral stenosis at the time of balloon inflations during percutaneous mitral valvuloplasty performed with a self-positioning Inoue balloon, which fits tightly in the mitral orifice. When mitral inflow was impeded in anesthetized dogs, left ventricular pressure decayed to a negative asymptote value. This negative asymptote value was consistent with an early diastolic suction effect. Tip-micromanometer left ventricular pressure recordings were obtained in 23 patients with symptomatic mitral stenosis at the time of balloon inflations during percutaneous mitral valvuloplasty performed with a self-positioning Inoue balloon. The left ventricular diastolic asymptote pressure (P(asy)) was determined in 47 nonfilling beats with a sufficiently long (greater than 200 ms) diastolic time interval (that is, the interval from minimal first derivative of left ventricular pressure to left ventricular end-diastolic pressure) and equaled 2 +/- 3 mm Hg for beats with normal intraventricular conduction and 3 +/- 2 mm Hg for beats with aberrant intraventricular conduction. Left ventricular angiography was performed in five patients during the first inflation of the Inoue balloon at the time of complete balloon expansion. Left ventricular end-diastolic volume of the nonfilling beats averaged 38 +/- 14 ml and was comparable to the left ventricular end-systolic volume (39 +/- 19 ml) measured during baseline angiography before mitral valvuloplasty. Time constants of left ventricular pressure decay were calculated on 21 nonfilling beats with a diastolic time interval greater than 200 ms, normal intraventricular conduction and peak left ventricular pressure greater than 50 mm Hg. Time constants (T0 and TBF) derived from an exponential curve fit with zero asymptote pressure and with a best-fit asymptote pressure were compared with a time constant (T(asy)) derived from an exponential curve fit with the measured diastolic left ventricular asymptote pressure. The value for T(asy) (37 +/- 9 ms) was significantly smaller than that for TBF (68 +/- 28 ms, p less than 0.001) and the value for the measured diastolic left ventricular asymptote pressure (2 +/- 4 mm Hg) was significantly larger than that for the best-fit asymptote pressure (-9 +/- 11 mm Hg, p less than 0.001). T0 (44 +/- 20 ms) was significantly (p less than 0.01) different from TBF but not from T(asy). During balloon inflation of a self-positioning Inoue balloon, left ventricular pressure decayed continuously toward a positive asymptote value and left ventricular cavity volume was comparable to the left ventricular end-systolic volume of filling beats. In these nonfilling beats, the best-fit asymptote pressure was unrelated to the measured asymptote pressure and T0 was a better measure of T(asy) than was TBF. Reduced internal myocardial restoring forces, caused by different extracellular matrix of the human heart, reduced external myocardial restoring forces caused by low coronary perfusion pressure during the balloon inflation and inward motion of the balloon-occluded mitral valve into the left ventricular cavity could explain the failure to observe significant diastolic left ventricular suction in the human heart.
HeartMate II left ventricular assist system: from concept to first clinical use.
Griffith, B P; Kormos, R L; Borovetz, H S; Litwak, K; Antaki, J F; Poirier, V L; Butler, K C
2001-03-01
The HeartMate II left ventricular assist device (LVAD) (ThermoCardiosystems, Inc, Woburn, MA) has evolved from 1991 when a partnership was struck between the McGowan Center of the University of Pittsburgh and Nimbus Company. Early iterations were conceptually based on axial-flow mini-pumps (Hemopump) and began with purge bearings. As the project developed, so did the understanding of new bearings, computational fluid design and flow visualization, and speed control algorithms. The acquisition of Nimbus by ThermoCardiosystems, Inc (TCI) sped developments of cannulas, controller, and power/monitor units. The system has been successfully tested in more than 40 calves since 1997 and the first human implant occurred in July 2000. Multicenter safety and feasibility trials are planned for Europe and soon thereafter a trial will be started in the United States to test 6-month survival in end-stage heart failure.
Abolmaali, Nasreddin; Koch, Arne; Götzelt, Knut; Hahn, Gabriele; Fitze, Guido; Vogelberg, Christian
2010-07-01
To compare MRI-based functional pulmonary and cardiac measurements in the long-term follow-up of children operated on for left-sided congenital diaphragmatic hernia (CDH) with age- and body size-matched healthy controls. Twelve children who received immediate postnatal surgery for closure of isolated left-sided CDH were included and received basic medical examinations, pulmonary function testing and echocardiography. MRI included measurement of lung volume, ventricular function assessment and velocity-encoded imaging of the pulmonary arteries and was compared with the data for 12 healthy children matched for age and body size. While patients' clinical test results were not suspicious, comparison between the MRI data for patients and those for healthy controls revealed significant differences. In patients, the volumes of the left lungs were increased and the tidal volume was larger on the right side. While the stroke volumes of both ventricles were reduced, heart rate and ejection fraction were increased. Flow, acceleration time and cross-sectional area of the left pulmonary artery were reduced. Functional MRI detected pulmonary and cardiac findings in the late follow-up of CDH children which may be missed by standard clinical methods and might be relevant for decisions regarding late outcome and treatment.
Effects of heart rate on experimentally produced mitral regurgitation in dogs.
Yoran, C; Yellin, E L; Hori, M; Tsujioka, K; Laniado, S; Sonnenblick, E H; Frater, R W
1983-12-01
The effects of increasing heart rate (HR) on the hemodynamics of acute mitral regurgitation (MR) were studied in 8 open-chest dogs. Filling volume, regurgitant volume and stroke volume were calculated from electromagnetic probe measurements of mitral and aortic flows. The left atrial-left ventricular systolic pressure gradient was measured with micromanometers. The calculated effective mitral regurgitant orifice area varied from 10 to 128 mm2, with a consequent regurgitant fraction (regurgitant volume/filling volume) of 24 to 62%. After crushing the sinus node, HR was increased stepwise from 90 to 180 beats/min by atrial pacing while maintaining aortic pressure constant. With increasing HR, filling volume, stroke volume, regurgitant volume and regurgitant time decreased; total cardiac output, forward cardiac output, regurgitant output, systolic pressure gradient, regurgitant fraction and the regurgitant orifice did not change; left ventricular end-diastolic pressure decreased; and left atrial v-wave amplitude increased. These results indicate that in acute experimental MR with a wide spectrum of incompetence, the relative distribution of forward and regurgitant flows did not change with large increases in HR. At rates greater than 150 beats/min the atrial contraction occurs early and increases the amplitude of the left atrial v wave. This may contribute to the severity of pulmonary congestion in patients with MR.
Vaidyanathan, Swaminathan; Kothandam, Sivakumar; Kumar, Rajesh; Indrajith, Sujatha Desai; Agarwal, Ravi
2017-01-01
A 26-year-old lady presented with exertional dyspnea, palpitations, central cyanosis, and oxygen saturations of 80% in room air. Her electrocardiogram, echocardiogram, and cardiac magnetic resonance were diagnostic of arrhythmogenic right ventricular dysplasia. There was no documented ventricular arrhythmia or syncopal episodes and Holter recordings were repeatedly normal. Cardiac hemodynamics showed right to left shunt through atrial septal defect, low pulmonary blood flow, normal atrial pressures, and minimally elevated right ventricular end-diastolic pressures. Since her presenting symptoms and cyanosis were attributed to reduced pulmonary blood flow, she underwent off-pump cavopulmonary anastomosis between right superior vena cava and right pulmonary artery. As we intended to avoid the adverse effect of extracorporeal circulation on the myocardial function and pulmonary vasculature, we did not attempt to reduce the size of the atrial septal defect. Her postoperative period was uneventful; oxygen saturation improved to 89% with significant improvement in effort tolerance. At 18-month follow-up, there were no ventricular arrhythmias on surveillance. The clinical presentation of this disease may vary from serious arrhythmias warranting defibrillators and electrical ablations at one end to right ventricular pump failure warranting cardiomyoplasty or right ventricular exclusion procedures at the other end. However, when the presentation was unusual with severe cyanosis through a stretched foramen ovale leading to reduced pulmonary blood flows, Glenn shunt served as a good palliation and should be considered as one of the options in such patients.
Fukamachi, Kiyotaka; Popović, Zoran B; Inoue, Masahiro; Doi, Kazuyoshi; Schenk, Soren; Ootaki, Yoshio; Kopcak, Michael W; McCarthy, Patrick M
2004-03-01
The objective of this study was to evaluate the changes in mitral annular and left ventricular dimensions and left ventricular pressure-volume relations produced by the Myocor Coapsys device that has been developed to treat functional mitral regurgitation (MR) off-pump. The Coapsys device, which consists of anterior and posterior epicardial pads connected by a sub-valvular chord, was implanted in seven dogs with functional MR resulting from pacing induced cardiomyopathy. The Coapsys device was then sized by drawing the posterior leaflet and annulus toward the anterior leaflet. During sizing, MR grade was assessed using color flow Doppler echocardiography. Final device size was selected when MR was eliminated or minimized. Following implantation, heart failure was maintained by continued pacing for a period of 8 weeks. Mitral annular and left ventricular dimensions and left ventricular pressure-volume relations were evaluated by two-dimensional echocardiography and a conductance catheter, respectively, at pre-sizing, post-sizing, and after 8 weeks. All implants were performed on beating hearts without cardiopulmonary bypass. Mean MR grade was reduced from 2.9+/-0.7 at pre-sizing to 0.7+/-0.8 at post-sizing (P<0.001), and was maintained at 0.8+/-0.8 after 8 weeks (P<0.01). The septal-lateral dimensions were significantly reduced at both mitral annular level [2.4+/-0.2 cm at pre-sizing, 1.5+/-0.3 cm at post-sizing (P<0.001) and 1.8+/-0.3 cm after 8 weeks (P<0.05)] and mid-papillary level [4.1+/-0.4 cm at pre-sizing, 2.4+/-0.2 cm at post-sizing (P<0.001) and 3.3+/-0.4 cm after 8 weeks (P<0.001)]. The end-systolic pressure-volume relation shifted leftward at post-sizing with a significantly steeper slope (P=0.03). There was a significant (P=0.03) leftward shift of the end-diastolic pressure-volume relation at post-sizing. After 8 weeks, these changes in pressure-volume relations tended to return to pre-sizing relations. The Coapsys device significantly reduced MR by treating both the mitral annular dilatation and the papillary muscle displacement. Despite these significant dimensional changes, the Coapsys device did not negatively affect the left ventricular pressure-volume relations.
Giant and thrombosed left ventricular aneurysm
de Agustin, Jose Alberto; de Diego, Jose Juan Gomez; Marcos-Alberca, Pedro; Rodrigo, Jose Luis; Almeria, Carlos; Mahia, Patricia; Luaces, Maria; Garcia-Fernandez, Miguel Angel; Macaya, Carlos; de Isla, Leopoldo Perez
2015-01-01
Left ventricular aneurysms are a frequent complication of acute extensive myocardial infarction and are most commonly located at the ventricular apex. A timely diagnosis is vital due to the serious complications that can occur, including heart failure, thromboembolism, or tachyarrhythmias. We report the case of a 78-year-old male with history of previous anterior myocardial infarction and currently under evaluation by chronic heart failure. Transthoracic echocardiogram revealed a huge thrombosed and calcified anteroapical left ventricular aneurysm. Coronary angiography demonstrated that the left anterior descending artery was chronically occluded, and revealed a big and spherical mass with calcified borders in the left hemithorax. Left ventriculogram confirmed that this spherical mass was a giant calcified left ventricular aneurysm, causing very severe left ventricular systolic dysfunction. The patient underwent cardioverter-defibrillator implantation for primary prevention. PMID:26225205
Germain, Dominique P; Weidemann, Frank; Abiose, Ademola; Patel, Manesh R; Cizmarik, Marta; Cole, J Alexander; Beitner-Johnson, Dana; Benistan, Karelle; Cabrera, Gustavo; Charrow, Joel; Kantola, Ilkka; Linhart, Ales; Nicholls, Kathy; Niemann, Markus; Scott, C Ronald; Sims, Katherine; Waldek, Stephen; Warnock, David G; Strotmann, Jörg
2013-12-01
The aim of this study was to evaluate the progression of left ventricular hypertrophy in untreated men with Fabry disease and to assess the effects of agalsidase-β (recombinant human α-galactosidase A) on left ventricular hypertrophy. Longitudinal Fabry Registry data were analyzed from 115 men treated with agalsidase-β (1 mg/kg/2 weeks) and 48 untreated men. Measurements included baseline left-ventricular mass and at least one additional left-ventricular mass assessment over ≥ 2 years. Patients were grouped into quartiles, based on left-ventricular mass slopes. Multivariate logistic regression analyses identified factors associated with left ventricular hypertrophy progression. For men in whom treatment was initiated at the age of 18 to <30 years, mean left ventricular mass slope was -3.6 g/year (n = 31) compared with +9.5 g/year in untreated men of that age (n = 15) (P < 0.0001). Untreated men had a 3.4-fold higher risk of having faster increases in left-ventricular mass compared with treated men (odds ratio: 3.43; 95% confidence interval: 1.05-11.22; P = 0.0415). A baseline age of ≥ 40 years was also associated with left--ventricular hypertrophy progression (odds ratio: 5.03; 95% confidence interval: 1.03-24.49; P = 0.0457) compared with men younger than 30 years. Agalsidase-β treatment for ≥2 years may improve or stabilize left-ventricular mass in men with Fabry disease. Further investigations may determine whether early intervention and stabilization of LVM are correlated with clinical outcomes.
Left isomerism syndrome with total anomalous systemic connection.
Vo, Anh Tuan; Cao, Khang Dang; Le, Khoi Minh; Nguyen, Dinh Hoang
2017-01-01
We present a case of left isomerism with total anomalous systemic venous connection where the inferior vena cava was absent and all other systemic veins connected abnormally to the left atrium. The right atrium was hypoplastic with an intact atrial septum. Blood flow to the lungs was through a large ventricular septal defect. The diagnosis was made with echocardiography, angiography, and computed tomography. Complete repair was performed successfully, and the 7-year-old patient had an uneventful recovery.
Acquired heart block: a possible complication of patent ductus arteriosus in a preterm infant.
Grasser, Monika; Döhlemann, Christoph; Mittal, Rashmi; Till, Holger; Dietz, Hans-Georg; Münch, Georg; Holzinger, Andreas
2008-01-01
A large patent ductus arteriosus (PDA) is a frequently encountered clinical problem in extremely low birth weight (ELBW) infants. It leads to an increased pulmonary blood flow and in a decreased or reversed diastolic flow in the systemic circulation, resulting in complications. Here we report a possible complication of PDA not previously published. On day 8 of life, a male ELBW infant (birth weight 650 g) born at a gestational age of 23 weeks and 3 days developed an atrioventricular block (AV block). The heart rate dropped from 168/min to 90/min, and the ECG showed a Wenckebach second-degree AV block and intraventricular conduction disturbances. Echocardiography demonstrated a PDA with a large left-to-right shunt and large left atrium and left ventricle with high contractility. Within several minutes after surgical closure of the PDA, the heart rate increased, and after 30 min the AV block had improved to a 1:1 conduction ratio. Echocardiography after 2 h revealed a significant decrease of the left ventricular and atrial dimensions. Within 12 h, the AV block completely reversed together with the intraventricular conduction disturbances. We suggest that PDA with a large left-to-right shunt and left ventricular volume overload may lead to an AV block in an ELBW infant. Surgical closure of the PDA may be indicated. (c) 2007 S. Karger AG, Basel.
Inhibition of coronary blood flow by a vascular waterfall mechanism.
Downey, J M; Kirk, E S
1975-06-01
The mechanism whereby systole inhibits coronary blood flow was examined. A branch of the left coronary artery was maximally dilated with an adenosine infusion, and the pressure-flow relationship was obtained for beating and arrested states. The pressure-flow curve for the arrested state was shifted toward higher pressures and in the range of pressures above peak ventricular pressure was linear and parallel to that for the arrested state. Below this range the curve for the beating state converged toward that for the arrested state and was convex to the pressure axis. These results were compared with a model of the coronary vasculature that consisted of numerous parallel channels, each responding to local intramyocardial pressure by forming vascular waterfalls. When intramyocardial pressure in the model was assigned values from zero at the epicardium to peak ventricular pressure at the endocardium, pressure-flow curves similar to the experimental ones resulted. Thus, we conclude that systole inhibits coronary perfusion by the formation of vascular waterfalls and that the intramyocardial pressures responsible for this inhibition do not significantly exceed peak ventricular pressure.
Kimura, Taro; Yokoyama, Yoshimasa; Sakota, Daisuke; Nagaoka, Eiki; Kitao, Takashi; Takakuda, Kazuo; Takatani, Setsuo
2013-03-01
The impact of continuous flow left ventricular assist device (LVAD) pumping on platelet aggregation was investigated in animal experiments utilizing six calves. A single-use MagLev centrifugal blood pump, MedTech MagLev, was used to bypass the calves' hearts from the left atrium to the descending aorta at a flow rate of 50 ml/kg/min. The LVAD's impact on blood coagulation activities was evaluated based on the platelet aggregability, which was measured with a turbidimetric assay method during the preoperative, operative, and postoperative periods. Heparin and warfarin were used for anticoagulation, while aspirin was used for the antiplatelet therapy. A decrease in platelet aggregation immediately after the pump started was observed in the cases of successful long-term pump operation, while the absence of such a decrease might have caused coagulation-related complications to terminate the experiments. Thus, the platelet aggregability was found to be significantly affected by the pump, and its initial trend may be related to the long-term outcome of the mechanical circulatory support.
Bartoli, Carlo R; Kang, Jooeun; Zhang, David; Howard, Jessica; Acker, Michael; Atluri, Pavan; Motomura, Tadashi
2017-04-01
Supraphysiologic shear stress from continuous-flow left ventricular assist devices (LVADs) accelerates von Willebrand factor (vWF) degradation and predisposes patients to nonsurgical bleeding. It is unknown whether unique design characteristics of LVADs differentially affect vWF degradation. We tested the hypothesis that the centrifugal-flow EVAHEART (Evaheart, Houston, TX) left ventricular assist system (LVAS), which was designed to minimize shear stress (low operational revolutions per minute [rpm], larger flow gaps, low shear stress, flat H-Q curve), reduced vWF degradation versus the axial-flow HeartMate II (Thoratec, Pleasanton, CA) LVAD. Whole human blood was obtained from volunteer donors (n = 22). Blood was circulated for 12 hours in mock circulatory loops through a HeartMate II (n = 10; 11,400 rpm, 6.3 ± 0.8 L/min, 76 ± 2 mm Hg) or an EVAHEART LVAS (n = 12; 2,300 rpm, 5.7 ± 0.1 L/min, 80 ± 1 mm Hg). vWF degradation was characterized with electrophoresis and immunoblotting for large vWF multimers and 11 vWF degradation fragments. The HeartMate II eliminated large vWF multimers and significantly (p < 0.05) increased 10 of 11 vWF degradation fragments at 6 and 12 hours. The increase was approximately 2.0-fold at 6 hours and 2.2-fold at 12 hours. In contrast, the EVAHEART LVAS modestly reduced large vWF multimers and significantly increased 5 of 11 and 8 of 11 vWF degradation fragments at 6 and 12 hours, respectively. The increase was approximately 1.5-fold at 6 hours and 1.7-fold at 12 hours. The EVAHEART LVAS caused significantly less degradation (p < 0.01) than the HeartMate II of the 140 kDa vWF fragment (cleavage product of ADAMTS-13, the vWF protease). The EVAHEART LVAS caused significantly less vWF degradation than the HeartMate II in a mock circulatory loop with whole human blood. LVAD design features may minimize vWF degradation. These data may inform the design and operation of next-generation LVADs to minimize blood trauma. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Left Ventricular Assist Devices: The Adolescence of a Disruptive Technology.
Pinney, Sean P
2015-10-01
Clinical outcomes for patients with advanced heart failure receiving left ventricular assist devices are driven by appropriate patient selection, refined surgical technique, and coordinated medical care. Perhaps even more important is innovative pump design. The introduction and widespread adoption of continuous-flow ventricular assist devices has led to a paradigm shift within the field of mechanical circulatory support, making the promise of lifetime device therapy closer to reality. The disruption caused by this new technology, on the one hand, produced meaningful improvements in patient survival and quality of life, but also introduced new clinical challenges, such as bleeding, pump thrombosis, and acquired valvular heart disease. Further evolution within this field will require financial investment to sustain innovation leading to a fully implantable, durable, and cost-effective pump for a larger segment of patients with advanced heart failure. Copyright © 2015 Elsevier Inc. All rights reserved.
Echocardiographic left ventricular masses in distance runners and weight lifters
NASA Technical Reports Server (NTRS)
Longhurst, J. C.; Gonyea, W. J.; Mitchell, J. H.; Kelly, A. R.
1980-01-01
The relationships of different forms of exercise training to left ventricular mass and body mass are investigated by echocardiographic studies of weight lifters, long-distance runners, and comparatively sized untrained control subjects. Left ventricular mass determinations by the Penn convention reveal increased absolute left ventricular masses in long-distance runners and competitive weight lifters with respect to controls matched for age, body weight, and body surface area, and a significant correlation between ventricular mass and lean body mass. When normalized to lean body mass, the ventricular masses of distance runners are found to be significantly higher than those of the other groups, suggesting that dynamic training elevates left ventricular mass compared to static training and no training, while static training increases ventricular mass only to the extent that lean body mass is increased.
Chen, Ming; Luo, Huai; Miyamoto, Takashi; Atar, Shaul; Kobal, Sergio; Rahban, Masoud; Brasch, Andrea V; Makkar, Rajendra; Neuman, Yoram; Naqvi, Tasneem Z; Tolstrup, Kirsten; Siegel, Robert J
2003-09-01
We assessed aortic regurgitation (AR) severity by utilizing multiple echo-Doppler variables in comparison with AR severity by aortic root angiography. Patients were divided into 3 groups: mild, moderate, and severe. An AR index (ARI) was developed, comprising 5 echocardiographic parameters: ratio of color AR jet height to left ventricular outlet flow diameter, AR signal density from continuous-wave Doppler, pressure half-time, left ventricular end-diastolic diameter, and aortic root diameter. There was a strong correlation between AR severity by angiography and the calculated echo-Doppler ARI (r = 0.84, p = 0.0001). As validated by aortic angiography, the ARI is an accurate reflection of AR severity.
Kumar, Alok; Puri, Goverdhan Dutt; Bahl, Ajay
2017-10-01
Speckle tracking, when combined with 3-dimensional (3D) left ventricular ejection fraction, might prove to be a more sensitive marker for postoperative ventricular dysfunction. This study investigated early outcomes in a cohort of patients with left ventricular dysfunction undergoing cardiac surgery. Prospective, blinded, observational study. University hospital; single institution. The study comprised 73 adult patients with left ventricular ejection fraction <50% undergoing cardiac surgery using cardiopulmonary bypass. Routine transesophageal echocardiography before and after bypass. Global longitudinal strain using speckle tracking and 3D left ventricular ejection fraction were computed using transesophageal echocardiography. Mean prebypass global longitudinal strain and 3D left ventricle ejection fraction were significantly lower in patients with postoperative low-cardiac-output syndrome compared with patients who did not develop low cardiac output (global longitudinal strain -7.5% v -10.7% and 3D left ventricular ejection fraction 29% v 39%, respectively; p < 0.0001). The cut-off value of global longitudinal strain predicting postoperative low-cardiac-output syndrome was -6%, with 95% sensitivity and 68% specificity; and 3D left ventricular ejection fraction was 19% with 98% sensitivity and 81% specificity. Preoperative left ventricular global longitudinal strain (-6%) and 3D left ventricular ejection fraction (19%) together could act as predictor of postoperative low-cardiac-output states with high sensitivity (99.9%) in patients undergoing cardiac surgery. Copyright © 2017 Elsevier Inc. All rights reserved.
Lagrangian coherent structures in the left ventricle in the presence of aortic valve regurgitation
NASA Astrophysics Data System (ADS)
di Labbio, Giuseppe; Vetel, Jerome; Kadem, Lyes
2017-11-01
Aortic valve regurgitation is a rather prevalent condition where the aortic valve improperly closes, allowing filling of the left ventricle of the heart to occur partly from backflow through the aortic valve. Although studies of intraventricular flow are rapidly gaining popularity in the fluid dynamics research community, much attention has been given to the left ventricular vortex and its potential for early detection of disease, particularly in the case of dilated cardiomyopathy. Notably, the subsequent flow in the left ventricle in the presence of aortic valve regurgitation ought to be appreciably disturbed and has yet to be described. Aortic valve regurgitation was simulated in vitro in a double-activation left heart duplicator and the ensuing flow was captured using two-dimensional time-resolved particle image velocimetry. Further insight into the regurgitant flow is obtained by computing attracting and repelling Lagrangian coherent structures. An interesting interplay between the two inflowing jets and their shear layer roll-up is observed for various grades of regurgitation. This study highlights flow features which may find use in further assessing regurgitation severity.
Tan, Yong-Qiang Benjamin; Ngiam, Jinghao Nicholas; Kong, William K F; Yeo, Tiong-Cheng; Poh, Kian-Keong
2016-10-15
Paradoxical low-flow aortic stenosis (AS) with preserved left ventricular ejection fraction (LVEF) has only been described in severe AS. Controversy surrounds prognosis and management but no studies have reported this phenomenon in mild or moderate AS. We investigated the prevalence of flow and gradient patterns in this population, characterising their clinical and echocardiographic profile. Consecutive subjects (n=1362) with isolated AS: mild (n=462, aortic valve area≥1.5cm(2), 2.5m/s
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poręba, Rafał, E-mail: sogood@poczta.onet.pl; Skoczyńska, Anna; Gać, Paweł
2012-09-15
The aim of the study was to evaluate left ventricular diastolic function in workers occupationally exposed to mercury vapour without clinical presentation of cardiac involvement. The studies included 115 workers (92 men and 23 women) occupationally exposed to mercury vapour without clinical presentation of cardiac involvement (mean age: 47.83 ± 8.29). Blood samples were taken to determine blood lipid profile, urine was collected to estimate mercury concentration (Hg-U) and echocardiographic examination was performed to evaluate diastolic function of the left ventricle. In the entire group of workers occupationally exposed to mercury vapour without clinical presentation of cardiac involvement, Spearman correlationsmore » analysis demonstrated the following significant linear relationships: between body mass index (BMI) and ratio of maximal early diastolic mitral flow velocity/early diastolic mitral annular velocity (E/E') (r = 0.32, p < 0.05), between serum HDL concentration and E/E' (r = − 0.22, p < 0.05), between Hg-U and E/E' (r = 0.35, p < 0.05), between Hg-U and isovolumetric relaxation time (IVRT') (r = 0.41, p < 0.05), between Hg-U and ratio of maximal early diastolic mitral flow velocity/maximal late diastolic mitral flow velocity (E/A) (r = − 0.31, p < 0.05) and between serum HDL concentration and E/A (r = 0.43, p < 0,05). In logistic regression analysis it as shown that independent factors of left ventricular diastolic dysfunction risk in the study group included a higher urine mercury concentration, a higher value of BMI and a lower serum HDL concentration (OR{sub Hg}-{sub U} = 1.071, OR{sub BMI} = 1.200, OR{sub HDL} = 0.896, p < 0.05). Summing up, occupational exposure to mercury vapour may be linked to impaired left ventricular diastolic function in workers without clinical presentation of cardiac involvement. -- Highlights: ► Study aimed at evaluation of LVDD in workers occupationally exposed to Hg. ► There was significant linear relationships between Hg-U and E/E'. ► Independent risk factor of LVDD in study group included higher Hg-U. ► Independent risk factor of LVDD in study group included higher BMI and lower HDL. ► Occupational exposure to Hg may be linked to LVDD.« less
Guppy-Coles, Kristyan B; Prasad, Sandhir B; Smith, Kym C; Hillier, Samuel; Lo, Ada; Atherton, John J
2015-06-01
We aimed to determine the feasibility of training cardiac nurses to evaluate left ventricular function utilising a semi-automated, workstation-based protocol on three dimensional echocardiography images. Assessment of left ventricular function by nurses is an attractive concept. Recent developments in three dimensional echocardiography coupled with border detection assistance have reduced inter- and intra-observer variability and analysis time. This could allow abbreviated training of nurses to assess cardiac function. A comparative, diagnostic accuracy study evaluating left ventricular ejection fraction assessment utilising a semi-automated, workstation-based protocol performed by echocardiography-naïve nurses on previously acquired three dimensional echocardiography images. Nine cardiac nurses underwent two brief lectures about cardiac anatomy, physiology and three dimensional left ventricular ejection fraction assessment, before a hands-on demonstration in 20 cases. We then selected 50 cases from our three dimensional echocardiography library based on optimal image quality with a broad range of left ventricular ejection fractions, which was quantified by two experienced sonographers and the average used as the comparator for the nurses. Nurses independently measured three dimensional left ventricular ejection fraction using the Auto lvq package with semi-automated border detection. The left ventricular ejection fraction range was 25-72% (70% with a left ventricular ejection fraction <55%). All nurses showed excellent agreement with the sonographers. Minimal intra-observer variability was noted on both short-term (same day) and long-term (>2 weeks later) retest. It is feasible to train nurses to measure left ventricular ejection fraction utilising a semi-automated, workstation-based protocol on previously acquired three dimensional echocardiography images. Further study is needed to determine the feasibility of training nurses to acquire three dimensional echocardiography images on real-world patients to measure left ventricular ejection fraction. Nurse-performed evaluation of left ventricular function could facilitate the broader application of echocardiography to allow cost-effective screening and monitoring for left ventricular dysfunction in high-risk populations. © 2014 John Wiley & Sons Ltd.
Maltais, Simon; Tchantchaleishvili, Vahtang; Schaff, Hartzell V; Daly, Richard C; Suri, Rakesh M; Dearani, Joseph A; Topilsky, Yan; Stulak, John M; Joyce, Lyle D; Park, Soon J
2014-04-01
Patients with severe ischemic cardiomyopathy (left ventricular ejection fraction <25%) and severe ischemic mitral regurgitation have a poor survival with medical therapy alone. Left ventricular assist device as destination therapy is reserved for patients who are too high risk for conventional surgery. We evaluated our outcomes with conventional surgery within this population and the comparative effectiveness of these 2 therapies. We identified patients who underwent conventional surgery or left ventricular assist device as destination therapy for severe ischemic cardiomyopathy (left ventricular ejection fraction <25%) and severe mitral regurgitation. The era for conventional surgery spanned from 1993 to 2009 and from 2007 to 2011 for left ventricular assist device as destination therapy. We compared baseline patient characteristics and outcomes in terms of end-organ function and survival. A total of 88 patients were identified; 55 patients underwent conventional surgery (63%), and 33 patients (37%) received a left ventricular assist device as destination therapy. Patients who received left ventricular assist device as destination therapy had the increased prevalence of renal failure, inotrope dependency, and intra-aortic balloon support. Patients undergoing conventional surgery required longer ventilatory support, and patients receiving a left ventricular assist device required more reoperation for bleeding. Mortality rates were similar between the 2 groups at 30 days (7% in the conventional surgery group vs 3% in the left ventricular assist device as destination therapy group, P = .65) and at 1 year (22% in the conventional surgery group vs 15% in the left ventricular assist device as destination therapy group, P = .58). There was a trend toward improved survival in patients receiving a left ventricular assist device compared with the propensity-matched groups at 1 year (94% vs 71%, P = .171). The operative mortality and early survival after conventional surgery seem to be acceptable. For inoperable or prohibitive-risk patients, left ventricular assist device as destination therapy can be offered with similar outcomes. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Torres, Jose Luis; Shah, Bindi K; Greenberg, Richard M; Deger, Florin Titus; Gerstenfeld, Edward P
2010-10-01
We hypothesized that in patients with left ventricular dysfunction undergoing implant of a biventricular ICD, the local dominant frequency during early induced ventricular fibrillation would be higher at an epicardial left ventricular position compared to an endocardial right ventricular position. Patients undergoing implant of a biventricular ICD were studied. During ventricular fibrillation induction, bipolar electrograms were recorded from leads at an epicardial left ventricular position and an endocardial right ventricular position. Overlapping 2-s fast Fourier transforms were obtained for 6 s of ventricular fibrillation. The dominant frequency and organizational index were compared. Thirty-four patients (20 men, age 64 ± 11 years) underwent 57 inductions of ventricular fibrillation. Eighteen patients had non-ischemic dilated cardiomyopathy and 16 had ischemic dilated cardiomyopathy. The dominant frequency was higher at a lateral epicardial left ventricular position than an apical endocardial right ventricular position in 18 patients with non-ischemic dilated cardiomyopathy (LV epicardial 5.34 ± 0.37 Hz, RV endocardial 5.09 ± 0.41 Hz, p < 0.001), but not in 16 patients with ischemic dilated cardiomyopathy (LV epicardial 4.99 ± 0.57 Hz, RV epicardial 4.87 ± 0.65 Hz, p = 0.094). In patients with non-ischemic dilated cardiomyopathy, there is a dominant frequency gradient during early ventricular fibrillation induced at ICD testing from the lateral left ventricular epicardium to the apical right ventricular endocardium.
Sivakumar, Kothandam; Francis, Edwin; Krishnan, Prasad; Shahani, Jagdish
2006-11-01
In late presenters with transposition of the great arteries, intact ventricular septum, and regressing left ventricle, left ventricular retraining by pulmonary artery banding and aortopulmonary shunt is characterized by a stormy postoperative course and high costs. Ductal stenting in the cardiac catheterization laboratory is conceptualized to retrain the left ventricle with less morbidity. Recanalization and transcatheter stenting of patent ductus arteriosus was performed in patients with transposition to induce pressure and volume overload to the regressing left ventricle. Serial echocardiographic monitoring of left ventricular shape, mass, free wall thickness, and volumes was done, and once the left ventricle was adequately prepared, an arterial switch was performed. The ductal stent was removed and the remaining surgical steps were similar to a 1-stage arterial switch operation. Postoperative course, need for inotropic agents, and left ventricular function were monitored. Ductal stenting in 2 patients aged 3 months resulted in improvement of indexed left ventricular mass from 18.9 to 108.5 g/m2, left ventricular free wall thickness from 2.5 to 4.8 mm, and indexed left ventricular volumes from 7.6 to 29.5 mL/m2 within 3 weeks. Both patients underwent arterial switch (bypass times 125 and 158 minutes) uneventfully, needed inotropic agents and ventilatory support for 3 days, and were discharged in 8 and 10 days. Ductal stenting is a less morbid method of left ventricular retraining in transposition of the great arteries with regressed left ventricle. Its major advantages lie in avoiding pulmonary artery distortion and neoaortic valve regurgitation resulting from banding and also in avoiding thoracotomy.
The Effect of Aortic Compliance on Left Ventricular Power Requirement
NASA Astrophysics Data System (ADS)
Pahlevan, Niema; Gharib, Morteza
2009-11-01
Aortic compliance depends on both geometry and mechanical properties of the aorta. Reduction in arterial compliance has been associated with aging, smoking, and multiple cardiovascular diseases. Increased stiffness of the aorta affects the wave dynamics in the aorta by increasing both pulse pressure amplitude and wave speed. We hypothesized that decreased aortic compliance leads to an increased left ventricular power requirement for a fixed cardiac output due to altered pulse pressure and pulse wave velocity. We used a computational approach using the finite element method for solid and fluid domains coupled to each other by using the direct coupling method. A nonlinear material model was used for the solid wall. The fluid flow model was considered to be Newtonian, incompressible, and laminar. The simulation was performed for a heart rate of 75 beats per minute for six different compliances while keeping the cardiac output and the peripheral resistance constant. The results show a trend towards increased left ventricular energy expenditure per cycle with decreased compliance. The relevance of these findings to clinical observations will be discussed.
Ayaz, Teslime; Kocaman, Sinan Altan; Durakoğlugil, Tuğba; Erdoğan, Turan; Şahin, Osman Zikrullah; Şahin, Serap Baydur; Çiçek, Yüksel; Şatiroğlu, Ömer
2014-01-01
Background and Objectives Left ventricular hypertrophy (LVH), a sign of subclinical cardiovascular disease, is an important predictor of cardiovascular morbidity and mortality. The aim of our study was to determine the association of left ventricular mass (LVM) with possible causative anthropometric and biochemical parameters as well as carotid intima-media thickness (CIMT) and brachial flow-mediated dilation (FMD) as surrogates of atherosclerosis and endothelial dysfunction, respectively, in previously untreated hypertensive patients. Subjects and Methods Our study included 114 consecutive previously untreated hypertensive patients who underwent echocardiography and ultrasonography to evaluate their vascular status and function via brachial artery CIMT and FMD. Results Among all study parameters, age, systolic blood pressure (BP), diastolic BP, pulse pressure, plasma glucose, uric acid, total bilirubin, direct bilirubin, hemoglobin, and CIMT were positively correlated with the LVM index. Multiple logistic regression analysis revealed that office systolic BP, age, male gender, and total bilirubin were independent predictors of LVH. Conclusion Bilirubin seems to be related to LVM and LVH. The positive association of bilirubin with these parameters is novel and requires further research. PMID:25278987
Chen, Jing; Yang, Zhi-Gang; Xu, Hua-Yan; Shi, Ke; Guo, Ying-Kun
2018-02-15
To assess left ventricular myocardial deformation in patients with primary cardiac tumors. MRI was retrospectively performed in 61 patients, including 31 patients with primary cardiac tumors and 30 matched normal controls. Left ventricular strain and function parameters were then assessed by MRI-tissue tracking. Differences between the tumor group and controls, left and right heart tumor groups, left ventricular wall tumor and non-left ventricular wall tumor groups, and tumors with and without LV enlargement groups were assessed. Finally, the correlations among tumor diameter, myocardial strain, and LV function were analyzed. Left ventricular myocardial strain was milder for tumor group than for normal group. Peak circumferential strain (PCS) and its diastolic strain rate, longitudinal strains (PLS) and its diastolic strain rates, and peak radial systolic and diastolic velocities of the right heart tumor group were lower than those of the left heart tumor group (all p<0.050), but the peak radial systolic strain rate of the former was higher than that of the latter (p=0.017). The corresponding strains were lower in the left ventricular wall tumor groups than in the non-left ventricular wall tumor group (p<0.050). Peak radial systolic velocities were generally higher for tumors with LV enlargement than for tumors without LV enlargement (p<0.050). Peak radial strain, PCS, and PLS showed important correlations with the left ventricular ejection fraction (all p<0.050). MRI-tissue tracking is capable of quantitatively assessing left ventricular myocardial strain to reveal sub-clinical abnormalities of myocardial contractile function. Copyright © 2017 Elsevier B.V. All rights reserved.
A large left ventricular thrombus.
Patanè, Salvatore; Marte, Filippo
2009-06-26
The discovery of a left ventricular mass obliges the clinician to perform a differential diagnosis including tumour or lipoma versus thrombus and its assessment presents important clinical implications. Dilated cardiomyopathy has been associated with left ventricular thrombosis which leads to substantial morbidity and mortality as a site for peripheral emboli. There are some studies on patients with dilated cardiomyopathy showing altered hemostasis and platelet behavior despite sinus rhythm. An increased incidence of thromboembolism is also well recognized in patients with left ventricular systolic dysfunction complicating history of myocardial infarction. Clinical dilemmas in treating left ventricular thrombus have been described too. We present a case of a large mobile left ventricular thrombus in a 71-year-old Italian man with dilated cardiomyopathy and history of myocardial infarction.
Khalafvand, S S; Ng, E Y K; Zhong, L; Hung, T K
2012-08-01
Pulsating blood flow patterns in the left ventricular (LV) were computed for three normal subjects and three patients after myocardial infarction (MI). Cardiac magnetic resonance (MR) images were obtained, segmented and transformed into 25 frames of LV for a computational fluid dynamics (CFD) study. Multi-block structure meshes were generated for 25 frames and 75 intermediate grids. The complete LV cycle was modelled by using ANSYS-CFX 12. The flow patterns and pressure drops in the LV chamber of this study provided some useful information on intra-LV flow patterns with heart diseases. Copyright © 2012 Elsevier Ltd. All rights reserved.
Calkoen, Emmeline E; Elbaz, Mohammed S M; Westenberg, Jos J M; Kroft, Lucia J M; Hazekamp, Mark G; Roest, Arno A W; van der Geest, Rob J
2015-11-01
During normal left ventricular (LV) filling, a vortex ring structure is formed distal to the left atrioventricular valve (LAVV). Vortex structures contribute to efficient flow organization. We aimed to investigate whether LAVV abnormality in patients with a corrected atrioventricular septal defect (AVSD) has an impact on vortex ring formation. Whole-heart 4D flow MRI was performed in 32 patients (age: 26 ± 12 years), and 30 healthy subjects (age: 25 ± 14 years). Vortex ring cores were detected at peak early (E-peak) and peak late filling (A-peak). When present, the 3-dimensional position and orientation of the vortex ring was defined, and the circularity index was calculated. Through-plane flow over the LAVV, and the vortex formation time (VFT), were quantified to analyze the relationship of vortex flow with the inflow jet. Absence of a vortex ring during E-peak (healthy subjects 0%, vs patients 19%; P = .015), and A-peak (healthy subjects 10% vs patients 44%; P = .008) was more frequent in patients. In 4 patients, this was accompanied by a high VFT (5.1-7.8 vs 2.4 ± 0.6 in healthy subjects), and in another 2 patients with abnormal valve anatomy. In patients compared with controls, the vortex cores had a more-anterior and apical position, closer to the ventricular wall, with a more-elliptical shape and oblique orientation. The shape of the vortex core closely resembled the valve shape, and its orientation was related to the LV inflow direction. This study quantitatively shows the influence of abnormal LAVV and LV inflow on 3D vortex ring formation during LV inflow in patients with corrected AVSD, compared with healthy subjects. Copyright © 2015. Published by Elsevier Inc.
Balaras, Elias; Cha, K S; Griffith, Bartley P; Gammie, James S
2009-03-01
Aortic valve bypass surgery treats aortic valve stenosis with a valve-containing conduit that connects the left ventricular apex to the descending thoracic aorta. After aortic valve bypass, blood is ejected from the left ventricle via both the native stenotic aortic valve and the conduit. We performed computational modeling to determine the effects of aortic valve bypass on aortic and cerebral blood flow, as well as the effect of conduit size on relative blood flow through the conduit and the native valve. The interaction of blood flow with the vascular boundary was modeled using a hybrid Eurelian-Lagrangian formulation, where an unstructured Galerkin finite element method was coupled with an immersed boundary approach. Our model predicted native (stenotic) valve to conduit flow ratios of 45:55, 52:48, and 60:40 for conduits with diameters of 20, 16, and 10 mm, respectively. Mean gradients across the native aortic valve were calculated to be 12.5, 13.8, and 17.6 mm Hg, respectively. Post-aortic valve bypass cerebral blood flow was unchanged from preoperative aortic valve stenosis configurations and was constant across all conduit sizes. In all cases modeled, cerebral blood flow was completely supplied by blood ejected across the native aortic valve. An aortic valve bypass conduit as small as 10 mm results in excellent relief of left ventricular outflow tract obstruction in critical aortic valve stenosis. The presence of an aortic valve bypass conduit has no effect on cerebral blood flow. All blood flow to the brain occurs via antegrade flow across the native stenotic valve; this configuration may decrease the long-term risk of cerebral thromboembolism.
De Lazzari, Claudio; Genuini, Igino; Quatember, Bernhard; Fedele, Francesco
2014-02-01
Patients assisted with left ventricular assist device (LVAD) may require prolonged mechanical ventilatory assistance secondary to postoperative respiratory failure. The goal of this work is the study of the interdependent effects LVAD like pulsatile catheter (PUCA) pump and mechanical ventilatory support or thoracic artificial lung (TAL), by the hemodynamic point of view, using a numerical simulator of the human cardiovascular system. In the simulator, different circulatory sections are described using lumped parameter models. Lumped parameter models have been designed to describe the hydrodynamic behavior of both PUCA pump and thoracic artificial lung. Ventricular behavior atrial and septum functions were reproduced using variable elastance model. Starting from simulated pathological conditions we studied the effects produced on some hemodynamic variables by simultaneous PUCA pump, thoracic artificial lung or mechanical ventilation assistance. Thoracic artificial lung was applied in parallel or in hybrid mode. The effects of mechanical ventilation have been simulated by changing mean intrathoracic pressure value from -4 mmHg to +5 mmHg. The hemodynamic variables observed during the simulations, in different assisted conditions, were: left and right ventricular end systolic (diastolic) volume, systolic/diastolic aortic pressure, mean pulmonary arterial pressure, left and right mean atrial pressure, mean systemic venous pressure and the total blood flow. Results show that the application of PUCA (without mechanical ventilatory assistance) increases the total blood flow, reduces the left ventricular end systolic volume and increases the diastolic aortic pressure. Parallel TAL assistance increases the right ventricular end diastolic (systolic) volume reduction both when PUCA is switched "ON" and both when PUCA is switched "OFF". By switching "OFF" the PUCA pump, it seems that parallel thoracic artificial lung assistance produces a greater cardiac output (respect to hybrid TAL assistance). Results concerning PUCA and TAL interaction produced by simulations cannot be compared with "in vivo" results since they are not presented in literature. But results concerning the effects produced by LVAD and mechanical ventilation have a trend consistent with those presented in literature. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Jobe, A; Ikegami, M; Jacobs, H; Jones, S
1984-01-01
Prematurely delivered lambs were treated with radiolabeled natural surfactant by either tracheal instillation at birth and before the onset of mechanical ventilation, or after 23 +/- 1 (+/- SE) min of mechanical ventilation. Right ventricular blood flow distributions, left ventricular outputs, and left-to-right ductal shunts were measured with radiolabeled microspheres. After sacrifice, the lungs of lambs receiving surfactant at birth inflated uniformly with constant distending pressure while the lungs of lambs treated after a period of ventilation had aerated, partially aerated, and atelectatic areas. All lungs were divided into pieces which were weighed and catalogued as to location. The amount of radiolabeled surfactant and microsphere-associated radioactivity in each piece of lung was quantified. Surfactant was relatively homogenously distributed to pieces of lung from lambs that were treated with surfactant at birth; 48% of lung pieces received amounts of surfactant within +/- 25% of the mean value. Surfactant was preferentially recovered from the aerated pieces of lungs of lambs treated after a period of mechanical ventilation, and the distribution of surfactant to these lungs was very nonhomogeneous. Right ventricular blood flow distributions to the lungs were quite homogeneous in both groups of lambs. However, in 8 of 12 lambs, pulmonary blood flow was preferentially directed away from those pieces of lung that received relatively large amounts of surfactant and toward pieces of lung that received less surfactant. This acute redirection of pulmonary blood flow distribution may result from the local changes in compliances within the lung following surfactant instillation. PMID:6546766
Muthiah, Kavitha; Gupta, Sunil; Otton, James; Robson, Desiree; Walker, Robyn; Tay, Andre; Macdonald, Peter; Keogh, Anne; Kotlyar, Eugene; Granger, Emily; Dhital, Kumud; Spratt, Phillip; Jansz, Paul; Hayward, Christopher S
2014-08-01
The aim of this study was to determine the contribution of pre-load and heart rate to pump flow in patients implanted with continuous-flow left ventricular assist devices (cfLVADs). Although it is known that cfLVAD pump flow increases with exercise, it is unclear if this increment is driven by increased heart rate, augmented intrinsic ventricular contraction, or enhanced venous return. Two studies were performed in patients implanted with the HeartWare HVAD. In 11 patients, paced heart rate was increased to approximately 40 beats/min above baseline and then down to approximately 30 beats/min below baseline pacing rate (in pacemaker-dependent patients). Ten patients underwent tilt-table testing at 30°, 60°, and 80° passive head-up tilt for 3 min and then for a further 3 min after ankle flexion exercise. This regimen was repeated at 20° passive head-down tilt. Pump parameters, noninvasive hemodynamics, and 2-dimensional echocardiographic measures were recorded. Heart rate alteration by pacing did not affect LVAD flows or LV dimensions. LVAD pump flow decreased from baseline 4.9 ± 0.6 l/min to approximately 4.5 ± 0.5 l/min at each level of head-up tilt (p < 0.0001 analysis of variance). With active ankle flexion, LVAD flow returned to baseline. There was no significant change in flow with a 20° head-down tilt with or without ankle flexion exercise. There were no suction events. Centrifugal cfLVAD flows are not significantly affected by changes in heart rate, but they change significantly with body position and passive filling. Previously demonstrated exercise-induced changes in pump flows may be related to altered loading conditions, rather than changes in heart rate. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Left ventricular function before and after kidney transplantation.
Omran, Mohammad T; Khakpour, Somayeh; Oliaie, Farshid
2009-06-01
To evaluate left ventricular function by echocardiography before and after kidney transplantation (KT). This analytical study included 50 patients that had successful KT in Shahid Beheshti Hospital, Babol, Iran from October 2005 to December 2007. The echocardiography study was performed by one cardiologist before and at least 3 months after KT. Data were analyzed by SPSS, and a p<0.05 was considered statistically significant. The mean age of patients was 33.94 +/- 11.66 years, 66% were male and 56% less than 45 years old. The ejection fraction and stroke volume after KT increased, however, the left ventricular end diastolic volume, left ventricular end systolic volume, left ventricular end systolic dimension, and left ventricular end diastolic diameter decreased. In patients with end stage renal disease, successful kidney transplantation could improve the function of the left ventricle.
Salemi, Vera Maria Cury; Fernandes, Fabio; Sirvente, Raquel; Nastari, Luciano; Rosa, Leonardo Vieira; Ferreira, Cristiano A; Pena, José Luiz Barros; Picard, Michael H; Mady, Charles
2009-01-01
We compared left ventricular regional wall motion, the global left ventricular ejection fraction, and the New York Heart Association functional class pre- and postoperatively. Endomyocardial fibrosis is characterized by fibrous tissue deposition in the endomyocardium of the apex and/or inflow tract of one or both ventricles. Although left ventricular global systolic function is preserved, patients exhibit wall motion abnormalities in the apical and inferoapical regions. Fibrous tissue resection in New York Heart Association FC III and IV endomyocardial fibrosis patients has been shown to decrease morbidity and mortality. We prospectively studied 30 patients (20 female, 30+/-10 years) before and 5+/-8 months after surgery. The left ventricular ejection fraction was determined using the area-length method. Regional left ventricular motion was measured by the centerline method. Five left ventricular segments were analyzed pre- and postoperatively. Abnormality was expressed in units of standard deviation from the mean motion in a normal reference population. Left ventricular wall motion in the five regions did not differ between pre- and postoperative measurements. Additionally, the left ventricular ejection fraction did not change after surgery (0.45+/-0.13% x 0.43+/-0.12% pre- and postoperatively, respectively). The New York Heart Association functional class improved to class I in 40% and class II in 43% of patients postoperatively (p<0.05). Although endomyocardial fibrosis patients have improved clinical symptoms after surgery, the global left ventricular ejection fraction and regional wall motion in these patients do not change. This finding suggests that other explanations, such as improvements in diastolic function, may be operational.
Lai, Chang Quan; Lim, Guat Ling; Jamil, Muhammad; Mattar, Citra Nurfarah Zaini; Biswas, Arijit; Yap, Choon Hwai
2016-10-01
The mechanics of intracardiac blood flow and the epigenetic influence it exerts over the heart function have been the subjects of intense research lately. Fetal intracardiac flows are especially useful for gaining insights into the development of congenital heart diseases, but have not received due attention thus far, most likely because of technical difficulties in collecting sufficient intracardiac flow data in a safe manner. Here, we circumvent such obstacles by employing 4D STIC ultrasound scans to quantify the fetal heart motion in three normal 20-week fetuses, subsequently performing 3D computational fluid dynamics simulations on the left ventricles based on these patient-specific heart movements. Analysis of the simulation results shows that there are significant differences between fetal and adult ventricular blood flows which arise because of dissimilar heart morphology, E/A ratio, diastolic-systolic duration ratio, and heart rate. The formations of ventricular vortex rings were observed for both E- and A-wave in the flow simulations. These vortices had sufficient momentum to last until the end of diastole and were responsible for generating significant wall shear stresses on the myocardial endothelium, as well as helicity in systolic outflow. Based on findings from previous studies, we hypothesized that these vortex-induced flow properties play an important role in sustaining the efficiency of diastolic filling, systolic pumping, and cardiovascular flow in normal fetal hearts.
Diagnostic electrocardiographic dyad criteria of emphysema in left ventricular hypertrophy
Lanjewar, Swapnil S; Chhabra, Lovely; Chaubey, Vinod K; Joshi, Saurabh; Kulkarni, Ganesh; Kothagundla, Chandrasekhar; Kaul, Sudesh; Spodick, David H
2013-01-01
Background The electrocardiographic diagnostic dyad of emphysema, namely a combination of the frontal vertical P-vector and a narrow QRS duration, can serve as a quasidiagnostic marker for emphysema, with specificity close to 100%. We postulated that the presence of left ventricular hypertrophy in emphysema may affect the sensitivity of this electrocardiographic criterion given that left ventricular hypertrophy generates prominent left ventricular forces and may increase the QRS duration. Methods We reviewed the electrocardiograms and echocardiograms for 73 patients with emphysema. The patients were divided into two groups based on the presence or absence of echocardiographic evidence of left ventricular hypertrophy. The P-vector, QRS duration, and forced expiratory volume in one second (FEV1) were computed and compared between the two subgroups. Results There was no statistically significant difference in qualitative lung function (FEV1) between the subgroups. There was no statistically significant difference in mean P-vector between the subgroups. The mean QRS duration was significantly longer in patients with left ventricular hypertrophy as compared with those without left ventricular hypertrophy. Conclusion The presence of left ventricular hypertrophy may not affect the sensitivity of the P-vector verticalization when used as a lone criterion for diagnosing emphysema. However, the presence of left ventricular hypertrophy may significantly reduce the sensitivity of the electrocardiographic diagnostic dyad in emphysema, as it causes a widening of the QRS duration. PMID:24293995
Diagnostic electrocardiographic dyad criteria of emphysema in left ventricular hypertrophy.
Lanjewar, Swapnil S; Chhabra, Lovely; Chaubey, Vinod K; Joshi, Saurabh; Kulkarni, Ganesh; Kothagundla, Chandrasekhar; Kaul, Sudesh; Spodick, David H
2013-01-01
The electrocardiographic diagnostic dyad of emphysema, namely a combination of the frontal vertical P-vector and a narrow QRS duration, can serve as a quasidiagnostic marker for emphysema, with specificity close to 100%. We postulated that the presence of left ventricular hypertrophy in emphysema may affect the sensitivity of this electrocardiographic criterion given that left ventricular hypertrophy generates prominent left ventricular forces and may increase the QRS duration. We reviewed the electrocardiograms and echocardiograms for 73 patients with emphysema. The patients were divided into two groups based on the presence or absence of echocardiographic evidence of left ventricular hypertrophy. The P-vector, QRS duration, and forced expiratory volume in one second (FEV1) were computed and compared between the two subgroups. There was no statistically significant difference in qualitative lung function (FEV1) between the subgroups. There was no statistically significant difference in mean P-vector between the subgroups. The mean QRS duration was significantly longer in patients with left ventricular hypertrophy as compared with those without left ventricular hypertrophy. The presence of left ventricular hypertrophy may not affect the sensitivity of the P-vector verticalization when used as a lone criterion for diagnosing emphysema. However, the presence of left ventricular hypertrophy may significantly reduce the sensitivity of the electrocardiographic diagnostic dyad in emphysema, as it causes a widening of the QRS duration.
Chronic animal experiment with magnetically suspended centrifugal pump.
Yamada, T; Nishimura, K; Park, C H; Kono, S; Yuasa, S; Tsukiya, T; Akamatsu, T; Matsuda, K; Ban, T
1997-07-01
We have been developing a new type of centrifugal pump for long-term use. The magnetically suspended centrifugal pump (MSCP) contains no shaft and seal so that long life expectancy is predicted. Paracorporeal left ventricular (LV) assist circulation between the left atrium and the descending aorta was instituted using sheep. The flow rates ranged from 2.5-5.5 L/min. The sheep that lived the longest (46 days) died of an embolism as a result of the thrombus in the pump. No thrombus formation was observed in other pumps. Plasma free hemoglobin levels ranged from 9 to 18 mg/dl, which led to the conclusion that the hemolysis level remained within an acceptable range. Two driving modes were compared. The slope of the pressure-flow relationship plot under a constant motor current mode was steeper than that under a constant rotational speed mode, and thus, the flow fluctuation decreased. In conclusion, the MSCP is durable for more than a month at the current stage of development and is a promising device for long-term ventricular assist.
Epinephrine and left atrial and left ventricular diastolic function decrease in normal subjects.
Fuenmayor, Abdel J; Solórzano, Moisés I; Gómez, Luisangelly
2016-10-01
We assessed the effect of epinephrine over left atrial and left ventricular diastolic function in subjects without structural heart disease. Twenty-seven, 34.6±17.2year-old patients without structural heart disease were included. Intravenous epinephrine (50 to 100ng/kg/min) was infused. Left atrial and ventricular functions were evaluated by means of echocardiography before and during the epinephrine infusion. No complications were observed. Significant increases in heart rate and systolic blood pressure were recorded. Both left atrial (minimal and maximal) volumes increased but increase in the minimal volume was more pronounced, and the ejection fraction diminished. Left atrial expansion index decreased and the fraction of left ventricular inflow volume resulting from atrial contraction increased. Two patients displayed abnormal left ventricular diastolic function. During epinephrine infusion, E/A and e' decreased, and isovolumetric relaxation time increased. In this group of young adults without structural heart disease, epinephrine infusion was safe, did not produce any complications, and induced a small but significant decrease in left atrial function and left ventricular diastolic function. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Qin, J. X.; Jones, M.; Shiota, T.; Greenberg, N. L.; Tsujino, H.; Firstenberg, M. S.; Gupta, P. C.; Zetts, A. D.; Xu, Y.; Ping Sun, J.;
2000-01-01
OBJECTIVES: To validate the accuracy of real-time three-dimensional echocardiography (RT3DE) for quantifying aneurysmal left ventricular (LV) volumes. BACKGROUND: Conventional two-dimensional echocardiography (2DE) has limitations when applied for quantification of LV volumes in patients with LV aneurysms. METHODS: Seven aneurysmal balloons, 15 sheep (5 with chronic LV aneurysms and 10 without LV aneurysms) during 60 different hemodynamic conditions and 29 patients (13 with chronic LV aneurysms and 16 with normal LV) underwent RT3DE and 2DE. Electromagnetic flow meters and magnetic resonance imaging (MRI) served as reference standards in the animals and in the patients, respectively. Rotated apical six-plane method with multiplanar Simpson's rule and apical biplane Simpson's rule were used to determine LV volumes by RT3DE and 2DE, respectively. RESULTS: Both RT3DE and 2DE correlated well with actual volumes for aneurysmal balloons. However, a significantly smaller mean difference (MD) was found between RT3DE and actual volumes (-7 ml for RT3DE vs. 22 ml for 2DE, p = 0.0002). Excellent correlation and agreement between RT3DE and electromagnetic flow meters for LV stroke volumes for animals with aneurysms were observed, while 2DE showed lesser correlation and agreement (r = 0.97, MD = -1.0 ml vs. r = 0.76, MD = 4.4 ml). In patients with LV aneurysms, better correlation and agreement between RT3DE and MRI for LV volumes were obtained (r = 0.99, MD = -28 ml) than between 2DE and MRI (r = 0.91, MD = -49 ml). CONCLUSIONS: For geometrically asymmetric LVs associated with ventricular aneurysms, RT3DE can accurately quantify LV volumes.
Phan, Kevin; Huo, Ya Ruth; Zhao, Dong Fang; Yan, Tristan D; Tchantchaleishvili, Vakhtang
2016-01-01
Several studies have reported that a portion of patients who exhibit cardiac recovery during left ventricular assist device (LVAD) support can have their device explanted with reasonable long-term survival. The aim of this systematic review is to assess the survival and cardiac function in patients with explanted LVADs from the current literature. Electronic search was performed to identify all studies in English literature assessing LVAD explantation. All identified articles were systematically assessed using the inclusion and exclusion criteria. Selected studies were subjected to quantitative assessment. From 5 electronic databases, 11 studies (213 patients) were included. Pooled mean perioperative mortality rate of those explanted was 9.2% (95% CI, 5.0-14.5%; I = 0). Pooled mean late mortality rate was 15% (95% CI, 9.0-22.1%; I = 31%). The pooled 1, 5, and 10 year survival postexplant was 91, 76, and 65.7%, respectively. Pooled postweaning freedom from heart failure (HF) recurrence reached 81.3%. Subset analysis demonstrated that patients explanted from a continuous-flow LVAD versus pulsatile LVAD had a lower rate of HF recurrence (6.6 vs. 28.3%, p = 0.03) and LVAD reimplantation (7.5 vs. 37%, p = 0.001). Before LVAD explantation, overall mean left ventricular ejection fraction (LVEF) was 49%. Weighted pooled early and late postexplantation mean LVEF was 47.3 and 41.2%, respectively. Late postexplantation LVEF was significantly higher in the continuous-flow versus pulsatile LVAD subgroup (41.5 vs. 24%, p = 0.001). This review shows encouraging safety and 10 year survival outcomes after explantation of LVADs in carefully selected patients, with rates better than expected after a heart transplant. Recovery of the native heart is the most desirable clinical outcome in patients supported with LVADs and should be actively sought.
Meng, Juan; Lu, Yuewu; Dong, Xin; Liu, Hongyan
2014-04-08
To observe the long-term effects of hydroxychloroquine treatment on blood lipids and left ventricular function of systemic lupus erythematosus (SLE) patients. A total of 72 SLE patients were randomly divided into 2 groups of hydroxychloroquine treatment (n = 36) and non-hydroxychloroquine (n = 36). The serum level of lipids, left ventricular end-diastolic diameter (LVEDD), left ventricular end-systolic diameter (LVESD), interventricular septum thickness (IVST), left ventricular posterior wall thickness (LVPWT), fractional shortening rate (FS), left ventricular ejection fraction (LVEF) and E/A ratio were measured before, 6 month, 12 month and 2 years after treatment. After long-term use of hydroxychloroquine, there were statistically differences in the levels of total cholesterol (TC), triglyceride (TG), low-density lipoprotein (LDL) and high-density lipoprotein (HDL). And LVEDD, LVWPT and E/A were statistically different (P < 0.05) before and after hydroxychloroquine dosing. The long-term use of hydroxychloroquine may improve lipid metabolism and left ventricular function in SLE patients.
Al-Nashi, Maha; Eriksson, Maria J; Östlund, Eva; Bremme, Katarina; Kahan, Thomas
2016-04-01
Preeclampsia (PE) is associated with acute left ventricular dysfunction. Whether these changes eventually resolve remains unclear. This study assessed left and right ventricular structure and function, and ventricular-arterial interaction in 15 women 11 years after a pregnancy with PE and 16 matched control subjects with a normal pregnancy. We found normal left and right ventricular dimensions, systolic function, and global left ventricular strain, with no differences between the groups. In addition, indices of diastolic function, left and right atrial size, and amino-terminal pro-brain natriuretic peptide were normal and did not differ between the groups. Women with a previous PE had impaired night/day ratios for systolic and diastolic ambulatory blood pressure. However, indices of aortic stiffness or ventricular-arterial coupling did not differ between the groups. In conclusion, we could not demonstrate remaining alterations in systolic or diastolic left or right ventricular function, or in ventricular-arterial interaction in women 11 years after PE. Copyright © 2016 American Society of Hypertension. Published by Elsevier Inc. All rights reserved.
Broyd, Christopher J; Rigo, Fausto; Nijjer, Sukhjinder; Sen, Sayan; Petraco, Ricardo; Al-Lamee, Rasha; Foin, Nicolas; Chukwuemeka, Andrew; Anderson, Jon; Parker, Jessica; Malik, Iqbal S; Mikhail, Ghada W; Francis, Darrel P; Parker, Kim; Hughes, Alun D; Mayet, Jamil; Davies, Justin E
2018-06-23
Severe aortic stenosis frequently involves the development of left ventricular hypertrophy (LVH) creating a dichotomous hemodynamic state within the coronary circulation. Whilst the increased force of ventricular contraction enhances its resultant relaxation and thus increases the distal diastolic coronary 'suction' force, the presence of LVH has a potentially opposing effect on ventricular-coronary interplay. The aim of this study was to use non-invasive coronary wave-intensity analysis (WIA) to separate and measure the sequential effects of outflow-tract obstruction relief and then left ventricular hypertrophy (LVH) regression following intervention for aortic stenosis. 15 patients with unobstructed coronary arteries undergoing aortic valve intervention (11 SAVR, 4 TAVI) were successfully assessed before and after intervention, and at 6- and 12-months post-procedure. Coronary WIA was constructed from simultaneously acquired coronary flow from transthoracic echo and pressure from an oscillometric brachial-cuff system. Immediately following intervention, a decline in the BDW was noted (9.7±5.7 vs 5.1±3.6 x10 3 Wm -2 s -1 , p<0.01). Over 12 months, LV mass-index fell from 114±19 to 82±17 kg/m 2 . Accompanying this, the BDW fraction increased to 32.8±7.2% (p=0.01 vs post-procedure) and to 34.7±6.7% at 12 months (p<0.001 vs post-procedure). In aortic stenosis, both the outflow-tract gradient and the presence of LVH impact significantly on coronary haemodynamics that cannot be appreciated by examining resting coronary flow rates alone. An immediate change in coronary wave-intensity occurs following intervention with further effects appreciable with hypertrophy regression. The improvement in prognosis with treatment is likely to be attributable to both features. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Measurement of left ventricular mass in vivo using gated nuclear magnetic resonance imaging.
Florentine, M S; Grosskreutz, C L; Chang, W; Hartnett, J A; Dunn, V D; Ehrhardt, J C; Fleagle, S R; Collins, S M; Marcus, M L; Skorton, D J
1986-07-01
Alterations of left ventricular mass occur in a variety of congenital and acquired heart diseases. In vivo determination of left ventricular mass, using several different techniques, has been previously reported. Problems inherent in some previous methods include the use of ionizing radiation, complicated geometric assumptions and invasive techniques. We tested the ability of gated nuclear magnetic resonance imaging to determine in vivo left ventricular mass in animals. By studying both dogs (n = 9) and cats (n = 2) of various sizes, a broad range of left ventricular mass (7 to 133 g) was examined. With a 0.5 tesla superconducting nuclear magnetic resonance imaging system the left ventricle was imaged in the transaxial plane and multiple adjacent 10 mm thick slices were obtained. Endocardial and epicardial edges were manually traced in each computer-displayed image. The wall area of each image was determined by computer and the areas were summed and multiplied by the slice thickness and the specific gravity of muscle, providing calculated left ventricular mass. Calculated left ventricular mass was compared with actual postmortem left ventricular mass using linear regression analysis. An excellent relation between calculated and actual mass was found (r = 0.95; SEE = 13.1 g; regression equation: magnetic resonance mass = 0.95 X actual mass + 14.8 g). Intraobserver and interobserver reproducibility were also excellent (r = 0.99). Thus, gated nuclear magnetic resonance imaging can accurately determine in vivo left ventricular mass in anesthetized animals.
Reduced coronary flow and resistance reserve in primary scleroderma myocardial disease
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nitenberg, A.; Foult, J.M.; Kahan, A.
1986-08-01
The maximum coronary vasodilator capacity after intravenous dipyridamole (0.14 mg X kg-1 X min-1 X 4 minutes) was studied in seven patients with primary scleroderma myocardial disease and compared to that of seven control subjects. Hemodynamic data and left ventricular angiographic data were not different in the two groups. The coronary flow reserve was evaluated by the dipyridamole/basal coronary sinus blood flow ratio (D/B CSBF) and the coronary resistance reserve by the dipyridamole/basal coronary resistance ratio (D/B CR). Coronary reserve was greatly impaired in the group with primary scleroderma myocardial disease: D/B CSBF was lower than in the control groupmore » (2.54 +/- 1.37 vs 4.01 +/- 0.56, respectively; p less than 0.05) and D/B CR was higher than in the control group (0.47 +/- 0.25 vs 0.23 +/- 0.04, respectively; p less than 0.05). Such a decreased coronary flow and resistance reserve in patients with primary scleroderma myocardial disease was not explained by an alteration of left ventricular function. It may be an important contributing factor in the pathogenesis of primary scleroderma myocardial disease.« less
Dissociation of end systole from end ejection in patients with long-term mitral regurgitation.
Brickner, M E; Starling, M R
1990-04-01
To determine whether left ventricular (LV) end systole and end ejection uncouple in patients with long-term mitral regurgitation, 59 patients (22 control patients with atypical chest pain, 21 patients with aortic regurgitation, and 16 patients with mitral regurgitation) were studied with micromanometer LV catheters and radionuclide angiograms. End systole was defined as the time of occurrence (Tmax) of the maximum time-varying elastance (Emax), and end ejection was defined as the time of occurrence of minimum ventricular volume (minV) and zero systolic flow as approximated by the aortic dicrotic notch (Aodi). The temporal relation between end systole and end ejection in the control patients was Tmax (331 +/- 42 [SD] msec), minV (336 +/- 36 msec), and then, zero systolic flow (355 +/- 23 msec). This temporal relation was maintained in the patients with aortic regurgitation. In contrast, in the patients with mitral regurgitation, the temporal relation was Tmax (266 +/- 49 msec), zero systolic flow (310 +/- 37 msec, p less than 0.01 vs. Tmax), and then, minV (355 +/- 37 msec, p less than 0.001 vs. Tmax and p less than 0.01 vs. Aodi). Additionally, the average Tmax occurred earlier in the patients with mitral regurgitation than in the control patients and patients with aortic regurgitation (p less than 0.01, for both), whereas the average time to minimum ventricular volume was similar in all three patient groups. Moreover, the average time to zero systolic flow also occurred earlier in the patients with mitral regurgitation than in the control patients (p less than 0.01) and patients with aortic regurgitation (p less than 0.05). Because of the dissociation of end systole from minimum ventricular volume in the patients with mitral regurgitation, the end-ejection pressure-volume relations calculated at minimum ventricular volume did not correlate (r = -0.09), whereas those calculated at zero systolic flow did correlate (r = 0.88) with the Emax slope values. We conclude that end ejection, defined as minimum ventricular volume, dissociates from end systole in patients with mitral regurgitation because of the shortened time to LV end systole in association with preservation of the time to LV end ejection due to the low impedance to ejection presented by the left atrium. Therefore, pressure-volume relations calculated at minimum ventricular volume might not be useful for assessing LV chamber performance in some patients with mitral regurgitation.
Ugata, Yusuke; Wada, Hiroshi; Sakakura, Kenichi; Ibe, Tatsuro; Ito, Miyuki; Ikeda, Nahoko; Fujita, Hideo; Momomura, Shin-Ichi
2018-01-27
Aerobic training based on anaerobic threshold (AT) is well-known to improve cardiac function, exercise capacity, and long-term outcomes of patients with heart failure. Recent reports suggested that high-intensity interval training (HIIT) for patients with cardiovascular disease may improve cardiopulmonary exercise capacity. We present a 61-year-old male patient of severe left ventricular dysfunction with left ventricular assisted device (LVAD). Following HIIT for 8 weeks, exercise capacity and muscle strength have improved without worsening left ventricular function. Our case showed the possibility that HIIT was feasible and effective even in patients with LVAD.
Right ventricular dysfunction affects survival after surgical left ventricular restoration.
Couperus, Lotte E; Delgado, Victoria; Palmen, Meindert; van Vessem, Marieke E; Braun, Jerry; Fiocco, Marta; Tops, Laurens F; Verwey, Harriëtte F; Klautz, Robert J M; Schalij, Martin J; Beeres, Saskia L M A
2017-04-01
Several clinical and left ventricular parameters have been associated with prognosis after surgical left ventricular restoration in patients with ischemic heart failure. The aim of this study was to determine the prognostic value of right ventricular function. A total of 139 patients with ischemic heart failure (62 ± 10 years; 79% were male; left ventricular ejection fraction 27% ± 7%) underwent surgical left ventricular restoration. Biventricular function was assessed with echocardiography before surgery. The independent association between all-cause mortality and right ventricular fractional area change, tricuspid annular plane systolic excursion, and right ventricular longitudinal peak systolic strain was assessed. The additive effect of multiple impaired right ventricular parameters on mortality also was assessed. Baseline right ventricular fractional area change was 42% ± 9%, tricuspid annular plane systolic excursion was 18 ± 3 mm, and right ventricular longitudinal peak systolic strain was -24% ± 7%. Within 30 days after surgery, 15 patients died. Right ventricular fractional area change (hazard ratio, 0.93; 95% confidence interval, 0.88-0.98; P < .01), tricuspid annular plane systolic excursion (hazard ratio, 0.80; 95% confidence interval, 0.66-0.96; P = .02), and right ventricular longitudinal peak systolic strain (hazard ratio, 1.15; 95% confidence interval, 1.05-1.26; P < .01) were independently associated with 30-day mortality, after adjusting for left ventricular ejection fraction and aortic crossclamping time. Right ventricular function was impaired in 21%, 20%, and 27% of patients on the basis of right ventricular fractional area change, tricuspid annular plane systolic excursion, and right ventricular longitudinal peak systolic strain, respectively. Any echocardiographic parameter of right ventricular dysfunction was present in 39% of patients. The coexistence of several impaired right ventricular parameters per patient was independently associated with increased 30-day mortality (hazard ratio, 2.83; 95% confidence interval, 1.64-4.87, P < .01 per additional impaired parameter). Baseline right ventricular systolic dysfunction is independently associated with increased mortality in patients with ischemic heart failure undergoing surgical left ventricular restoration. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Radionuclide evaluation of left ventricular function with nonimaging probes.
Wexler, J P; Blaufox, M D
1979-10-01
Portable nonimaging probes have been developed that can evaluate left ventricular function using radionuclide techniques. Two modes of data acquisition are possible with these probe systems, first-pass and gated. Precordial radiocardiograms obtained after a bolus injection can be used to determine cardiac output, pulmonary transit time, pulmonary blood volume, left ventricle ejection fraction, and left-to-right shunts. Gated techniques can be used to determine left ventricular ejection fraction and sytolic time intervals. Probe-determined indices of left ventricular function agree excellently with comparable measurements determined by conventional camera-computer methods as well as by invasive techniques. These have begun to be used in a preliminary manner in a variety of clinical problems associated with left ventricular dysfunction. This review discusses the types of probe systems available, the methods used in positioning them, and details the specifics of their data acquisition and processing capacity. The major criticisms of probe methods are that they are nonimaging and that they measure global rather than regional left ventricular function. In spite of these criticisms, probe systems, because of their portability, high sensitivity, and relatively low cost are useful supplements to conventional camera-computer systems for the measurement of parameters of left ventricular performance using radionuclide techniques.
Toemen, L; Gishti, O; van Osch-Gevers, L; Steegers, E A P; Helbing, W A; Felix, J F; Reiss, I K M; Duijts, L; Gaillard, R; Jaddoe, V W V
2016-07-01
Maternal obesity may affect cardiovascular outcomes in the offspring. We examined the associations of maternal prepregnancy body mass index and gestational weight gain with childhood cardiac outcomes and explored whether these associations were explained by parental characteristics, infant characteristics or childhood body mass index. In a population-based prospective cohort study among 4852 parents and their children, we obtained maternal weight before pregnancy and in early, mid- and late pregnancy. At age 6 years, we measured aortic root diameter (cm) and left ventricular dimensions. We calculated left ventricular mass (g), left ventricular mass index (g m(-2.7)), relative wall thickness ((2 × left ventricular posterior wall thickness)/left ventricular diameter), fractional shorting (%), eccentric left ventricular hypertrophy and concentric remodeling. A one standard deviation score (SDS) higher maternal prepregnancy body mass index was associated with higher left ventricular mass (0.10 SDS (95% confidence interval (CI) 0.08, 0.13)), left ventricular mass index (0.06 SDS (95% CI 0.03, 0.09)) and aortic root diameter (0.09 SDS (95% CI 0.06, 0.12)), but not with relative wall thickness or fractional shortening. A one SDS higher maternal prepregnancy body mass index was associated with an increased risk of eccentric left ventricular hypertrophy (odds ratio 1.21 (95% CI 1.03, 1.41)), but not of concentric remodeling. When analyzing the effects of maternal weight in different periods simultaneously, only maternal prepregnancy weight and early pregnancy weight were associated with left ventricular mass, left ventricular mass index and aortic root diameter (P-values<0.05), independent of weight in other pregnancy periods. All observed associations were independent of parental and infant characteristics, but attenuated to non-significance after adjustment for childhood body mass index. Maternal prepregnancy body mass index and weight gain in early pregnancy are both associated with offspring cardiac structure in childhood, but these associations seem to be fully explained by childhood body mass index.
Pereda, Daniel; García-Lunar, Inés; Sierra, Federico; Sánchez-Quintana, Damián; Santiago, Evelyn; Ballesteros, Constanza; Encalada, Juan F; Sánchez-González, Javier; Fuster, Valentín; Ibáñez, Borja; García-Álvarez, Ana
2016-09-01
Pulmonary hypertension (PH) and right ventricular (RV) dysfunction are strong predictors of morbidity and mortality among patients with congenital heart disease. Early detection of RV involvement may be useful in the management of these patients. We aimed to assess progressive cardiac adaptation and quantify myocardial extracellular volume in an experimental porcine model of PH because of aorto-pulmonary shunt using cardiac magnetic resonance (CMR). To characterize serial cardiac adaptation, 12 pigs (aorto-pulmonary shunt [n=6] or sham operation [n=6]) were evaluated monthly with right heart catheterization, CMR, and computed tomography during 4 months, followed by pathology analysis. Extracellular volume by CMR in different myocardial regions was studied in 20 animals (aorto-pulmonary shunt [n=10] or sham operation [n=10]) 3 months after the intervention. All shunted animals developed PH. CMR evidenced progressive RV hypertrophy and dysfunction secondary to increased afterload and left ventricular dilatation secondary to volume overload. Shunt flow by CMR strongly correlated with PH severity, left ventricular end-diastolic pressure, and left ventricular dilatation. T1-mapping sequences demonstrated increased extracellular volume at the RV insertion points, the interventricular septum, and the left ventricular lateral wall, reproducing the pattern of fibrosis found on pathology. Extracellular volume at the RV insertion points strongly correlated with pulmonary hemodynamics and RV dysfunction. Prolonged systemic-to-pulmonary shunting in growing piglets induces PH with biventricular remodeling and myocardial fibrosis that can be detected and monitored using CMR. These results may be useful for the diagnosis and management of congenital heart disease patients with pulmonary overcirculation. © 2016 American Heart Association, Inc.
Helder, Meghana R K; Ugur, Murat; Bavaria, Joseph E; Kshettry, Vibhu R; Groh, Mark A; Petracek, Michael R; Jones, Kent W; Suri, Rakesh M; Schaff, Hartzell V
2015-03-01
The study objective was to analyze factors associated with left ventricular mass regression in patients undergoing aortic valve replacement with a newer bioprosthesis, the Trifecta valve pericardial bioprosthesis (St Jude Medical Inc, St Paul, Minn). A total of 444 patients underwent aortic valve replacement with the Trifecta bioprosthesis from 2007 to 2009 at 6 US institutions. The clinical and echocardiographic data of 200 of these patients who had left ventricular hypertrophy and follow-up studies 1 year postoperatively were reviewed and compared to analyze factors affecting left ventricular mass regression. Mean (standard deviation) age of the 200 study patients was 73 (9) years, 66% were men, and 92% had pure or predominant aortic valve stenosis. Complete left ventricular mass regression was observed in 102 patients (51%) by 1 year postoperatively. In univariate analysis, male sex, implantation of larger valves, larger left ventricular end-diastolic volume, and beta-blocker or calcium-channel blocker treatment at dismissal were significantly associated with complete mass regression. In the multivariate model, odds ratios (95% confidence intervals) indicated that male sex (3.38 [1.39-8.26]) and beta-blocker or calcium-channel blocker treatment at dismissal (3.41 [1.40-8.34]) were associated with increased probability of complete left ventricular mass regression. Patients with higher preoperative systolic blood pressure were less likely to have complete left ventricular mass regression (0.98 [0.97-0.99]). Among patients with left ventricular hypertrophy, postoperative treatment with beta-blockers or calcium-channel blockers may enhance mass regression. This highlights the need for close medical follow-up after operation. Labeled valve size was not predictive of left ventricular mass regression. Copyright © 2015 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Terada, Tomomasa; Mori, Kazuhiro; Inoue, Miki; Yasunobu, Hayabuchi
2016-11-01
Assessment of longitudinal left ventricular (LV) function is important for early detection of cardiac dysfunction. Although mitral annular plane systolic excursion (MAPSE) obtained by M-mode echocardiography offers a simple method for assessing longitudinal LV function, normal values of MAPSE for children change according to body size. To minimize the effects of body size, MAPSE was divided by LV long-axis length (MAPSE/L). MAPSE/L was measured in 210 healthy children from birth to 15 years of age and classified into five subgroups. MAPSE/L was then compared with 10 parameters in 136 children (age, heart rate, mean blood pressure, ejection fraction of the LV (EF), peak atrial flow velocity/peak early diastolic flow velocity of mitral flow, tissue Doppler velocity during systole (s') and early diastole (e'), E/e' ratio, Tei index, and global longitudinal strain (GLS) of the LV by the speckle tracking method). MAPSE/L was significantly lower in the neonate group than in the remaining four groups. MAPSE/L then increased with age to peak at 1-5 years and gradually decreased thereafter. In all cases beyond the neonatal period, MAPSE/L was more than 0.17. Among various parameters, GLS, age, EF, Tei index and s' were significantly associated with MAPSE/L in that order. In univariate analysis, GLS was most significantly associated with MAPSE/L (r=.56). We have established normal reference values for MPSE/L in healthy children. MAPSE/L is expected to offer a simple parameter to evaluate LV longitudinal systolic function during daily routine echocardiography in children. © 2016, Wiley Periodicals, Inc.
Fluid-structure interaction in the left ventricle of the human heart coupled with mitral valve
NASA Astrophysics Data System (ADS)
Meschini, Valentina; de Tullio, Marco Donato; Querzoli, Giorgio; Verzicco, Roberto
2016-11-01
In this paper Direct Numerical Simulations (DNS), implemented using a fully fluid-structure interaction model for the left ventricle, the mitral valve and the flowing blood, and laboratory experiments are performed in order to cross validate the results. Moreover a parameter affecting the flow dynamics is the presence of a mitral valve. We model two cases, one with a natural mitral valve and another with a prosthetic mechanical one. Our aim is to understand their different effects on the flow inside the left ventricle in order to better investigate the process of valve replacement. We simulate two situations, one of a healthy left ventricle and another of a failing one. While in the first case the flow reaches the apex of the left ventricle and washout the stagnant fluid with both mechanical and natural valve, in the second case the disturbance generated by the mechanical leaflets destabilizes the mitral jet, thus further decreasing its capability to penetrate the ventricular region and originating heart attack or cardiac pathologies in general.
Protonotarios, Alexandros; Patrianakos, Alexandros; Spanoudaki, Elpida; Kochiadakis, Georgios; Michalodimitrakis, Emmanouel; Vardas, Panagiotis
2013-01-01
Left-dominant arrhythmogenic cardiomyopathy is a subtype of arrhythmogenic right ventricular cardiomyopathy characterized by early predominant left ventricular involvement. Α 34-year-old man presented with palpitations and a history of frequent ventricular extrasystoles of both LBBB and RBBB configuration. Cardiac workup revealed repolarization abnormalities at infero-lateral leads in the absence of diagnostic structural/functional alterations or obstructive coronary artery disease. Six months later he died suddenly. Histopathology was diagnostic for arrhythmogenic right ventricular cardiomyopathy affecting predominantly the left ventricle at subepicardial/midwall myocardial layers. Thus, ventricular arrhythmias accompanied by unexplained infero-lateral T-wave inversion should warn of a possible morbid association underlying left-dominant arrhythmogenic cardiomyopathy. Copyright © 2013 Elsevier Inc. All rights reserved.
Matsumoto, M; Hanrath, P; Kremer, P; Tams, C; Langenstein, B A; Schlüter, M; Weiter, R; Bleifeld, W
1982-01-01
In order to evaluate left ventricular function during dynamic exercise transoesophageal M-mode recordings of the left ventricle were carried out with a newly developed transducer gastroscope system. Twelve healthy subjects performed a graded supine bicycle exercise test. Stable and good quality images of the left ventricle at rest and during exercise at different steps up to a maximum workload of 100 watts were obtained in all patients. Isotonic maximum exercise resulted in a significant increase in fractional shortening of the left ventricle, peak shortening rate, and peak lengthening rate of the left ventricular minor axis. Left ventricular end-diastolic dimension decreased significantly. With increasing workload the pressure rate product increased significantly. It is concluded that transoesophageal M-mode echocardiography is a useful method of evaluating left ventricular performance during dynamic exercise. Images PMID:7082515
Change of heart dimensions and function during pregnancy in goats.
Szaluś-Jordanow, Olga; Czopowicz, Michał; Witkowski, Lucjan; Moroz, Agata; Mickiewicz, Marcin; Frymus, Tadeusz; Markowska-Daniel, Iwona; Bagnicka, Emilia; Kaba, Jarosław
2018-03-08
The study aimed to evaluate the effect of pregnancy on heart diameters and function in goats. Transthoracic echocardiography of 12 female dairy goats of two Polish regional breeds was performed. A Mindray M7 diagnostic ultrasound system with Phased Array transducer was used. Simultaneously, electrocardiography was recorded. All animals were examined four times - at mating season, at the end of the first trimester, at the end of the second trimester and just before kidding. Eleven measurements were taken each time: aortic and left atrial diameter (AoD and LAD), right and left ventricular internal diameter in diastole (RVIDd and LVIDd), left ventricular internal diameter in systole (LVIDs), inter-ventricular septum thickness in diastole and systole (IVSd and IVSd) and left ventricular posterior wall in diastole and systole (LVPWd and LVPWs), maximum left and right ventricular outflow tract velocity (RVOT Vmax and LVOT Vmax). Nine consecutive measurements were derived: the ratio of the left atrial diameter to the aortic diameter (AoD/LAD), left ventricular fractional shortening (FS%), left ventricular ejection fraction (EF%), maximum outflow tract pressure gradients (RVOT PGmax and LVOT PGmax), left ventricular end-diastolic volume (LVEDV) and left ventricular end-systolic volume (LVESV), stroke volume (SV) and cardiac output (CO). HR, LAD, LVPWs, IVSs increased significantly in the first trimester. AoD and RVIDd were significantly higher around parturition. LVIDd, FS%, EF%, SV and CO rose both in the first and third trimester. No measurement decreased during pregnancy. The study confirms that pregnancy causes changes in the heart size and functioning. Copyright © 2018. Published by Elsevier Ltd.
Remote magnetic navigation to map and ablate left coronary cusp ventricular tachycardia.
Burkhardt, J David; Saliba, Walid I; Schweikert, Robert A; Cummings, Jennifer; Natale, Andrea
2006-10-01
Premature ventricular contractions (PVCs) and ventricular tachycardia may arise from the coronary cusps. Navigation, mapping, and ablation in the coronary cusps can be challenging. Remote magnetic navigation may offer an alternative to conventional manually operated catheters. We report a case of left coronary cusp ventricular tachycardia ablation using remote magnetic navigation. Right ventricular outflow tract and coronary cusp mapping, and ablation of the left coronary cusp using a remote magnetic navigation and three-dimensional (3-D) mapping system was performed in a 28-year-old male with frequent, symptomatic PVCs and ventricular tachycardia. Successful ablation of left coronary cusp ventricular tachycardia was performed using remote magnetic navigation. Remote magnetic navigation may be used to map and ablate PVCs and ventricular tachycardia originating from the coronary cusps.
Guha, Ashrith; Nguyen, Duc; Cruz-Solbes, Ana S; Amione-Guerra, Javier; Schutt, Robert C; Bhimaraj, Arvind; Trachtenberg, Barry H; Park, Myung H; Graviss, Edward A; Gaber, Osama; Suarez, Erik; Montane, Eva; Torre-Amione, Guillermo; Estep, Jerry D
Patients bridged to transplant (BTT) with continuous-flow left ventricular assist devices (CF-LVADs) have increased in the past decade. Decision support tools for these patients are limited. We developed a risk score to estimate prognosis and guide decision-making. We included heart transplant recipients bridged with CF-LVADs from the United Network for Organ Sharing (UNOS) database and divided them into development (2,522 patients) and validation cohorts (1,681 patients). Univariate and multivariate Cox proportional hazards models were performed. Variables that independently predicted outcomes (age, African American race, recipient body mass index [BMI], intravenous [IV] antibiotic use, pretransplant dialysis, and total bilirubin) were assigned weight using linear transformation, and risk scores were derived. Patients were grouped by predicted posttransplant mortality: low risk (≤ 38 points), medium risk (38-41 points), and high risk (≥ 42 points). We performed Cox proportional hazards analysis on wait-listed CF-LVAD patients who were not transplanted. Score significantly discriminated survival among the groups in the development cohort (6.7, 12.9, 20.7; p = 0.001), validation cohort (6.4, 10.1, 13.6; p < 0.001), and ambulatory cohort (6.4, 11.5, 17.2; p < 0.001). We derived a left ventricular assist device (LVAD) BTT risk score that effectively identifies CF-LVAD patients who are at higher risk for worse outcomes after heart transplant. This score may help physicians weigh the risks of transplantation in patients with CF-LVAD.
Díaz-Arrieta, Gustavo; Mendoza-Hernández, María Elsa; Pacheco-Aranda, Erika; Rivas-Duro, Miguel; Robles-Parra, Héctor Manuel; Espinosa-Vázquez, Raúl Arturo; Hernández-Cabrera, Jorge
2010-01-01
In diabetic patients with chronic renal failure (CRF) treated with dialysis, the diastolic and systolic left ventricular dysfunction is frequent. The aim was to assess by echocardiography the prevalence of diastolic and systolic ventricular dysfunction in diabetic patients with CRF treated with continuous ambulatory peritoneal dialysis (CAPD). Sixty diabetic patients with CRF in CAPD were studied. The mean age was 54.5 +/- 12 years (27-78 years). The left ventricular filling pattern (LVFP) as a diastolic function parameter and left ventricular ejection fraction (LVEF) as a systolic function parameter were measured by transthoracic echocardiography. Descriptive statistical analysis was used. 27 (45 %) patients were women and 33 (55 %) were men. In 55 (91.7 %) left ventricular concentric hypertrophy was observed. Fifty-two patients (86.7 %) showed LVFP type I; three (5 %) had the type II; two (3.3 %) showed pseudonormal pattern and three (5 %) had a normal LVFP. The LVEF was 0.63 +/- 0.09 (CI = 0.41-0.82). Forty nine (81.7 %) patients had LVEF equal or greater than 0.55. The prevalence of diastolic left ventricular dysfunction was 95 % and the prevalence of systolic left ventricular dysfunction was 18.3%.
Malliaras, Konstantinos; Charitos, Efstratios; Diakos, Nikolaos; Pozios, Iraklis; Papalois, Apostolos; Terrovitis, John; Nanas, John
2014-12-01
We investigated the effects of intra-aortic balloon pump (IABP) counterpulsation on left ventricular (LV) contractility, relaxation, and energy consumption and probed the underlying physiologic mechanisms in 12 farm pigs, using an ischemia-reperfusion model of acute heart failure. During both ischemia and reperfusion, IABP support unloaded the LV, decreased LV energy consumption (pressure-volume area, stroke work), and concurrently improved LV mechanical performance (ejection fraction, stroke volume, cardiac output). During reperfusion exclusively, IABP also improved LV relaxation (tau) and contractility (Emax, PRSW). The beneficial effects of IABP support on LV relaxation and contractility correlated with IABP-induced augmentation of coronary blood flow. In conclusion, we find that during both ischemia and reperfusion, IABP support optimizes LV energetic performance (decreases energy consumption and concurrently improves mechanical performance) by LV unloading. During reperfusion exclusively, IABP support also improves LV contractility and active relaxation, possibly due to a synergistic effect of unloading and augmentation of coronary blood flow.
Pereira, Naveen L; Chen, Dong; Kushwaha, Sudhir S; Park, Soon J
2010-10-01
The recommended anticoagulation regimen during continuous-flow axial left ventricular assist device (LVAD) support is aspirin and warfarin with a targeted international normalized ratio of 2.0-3.0. We report two patients in whom recurrent gastrointestinal bleeding during LVAD support necessitated discontinuation of this anti-thrombotic regimen for a year or more. Despite this, neither patients developed thrombotic complications during 29 patient-months of follow-up. An acquired von Willebrand factor (VWF) abnormality reflected by the absence or decreased abundance of the highest molecular weight multimers was demonstrated in both patients. The gold standard test for platelet function, light transmission platelet aggregometry was measured in one patient and was normal, indicative that the predominant abnormality in the coagulation profile of these patients is an acquired VWF syndrome. Clinical trials are required to address the question whether it is safe to discontinue anticoagulation in LVAD patients with acquired VWF abnormalities.
Topilsky, Yan; Hasin, Tal; Oh, Jae K; Borgeson, Daniel D; Boilson, Barry A; Schirger, John A; Clavell, Alfredo L; Frantz, Robert P; Tsutsui, Rayji; Liu, Mingya; Maltais, Simon; Kushwaha, Sudhir S; Pereira, Naveen L; Park, Soon J
2011-11-01
Operative mortality after left ventricular assist device (LVAD) implantation is heavily influenced by patient selection and the technical difficulty of surgery. However, how we treat our patients and LVAD setting may affect the patient outcome beyond this period. We postulated that the presence of echocardiographic variables 1 month after surgery suggesting appropriate degree of LV unloading and an adequate forward flow would be important in determining clinical outcomes after the initial successful LVAD implantation. We retrospectively analyzed various variables in echocardiographic examinations performed 30 days after LVAD implant in 76 consecutive patients receiving continuous flow device for their association with a compound end point (90-day mortality, readmission for heart failure, or New York Heart Association class III or higher at the end of the 90-day period). The echocardiographic associations examined included estimated LVAD flow, with and without native LV contribution, interventricular septal position, the status of aortic valve opening, an estimated left atrial pressure (ELAP), the mitral flow E-wave deceleration time, and the ratio of deceleration time to E-wave velocity (mitral deceleration index [MDI]). Four patients died during the 30- to 90-day period, 6 patients were readmitted for heart failure, and 25 patients were considered to have New York Heart Association class III or higher at the end of the 90-day period. Variables associated with adverse outcome included increased ELAP (odds ratio, 1.30 [1.16-1.48]; P<0.0001), MDI <2 ms/[cm/s] (odds ratio, 4.4 implantation [1.22-18]; P=0.02) and decreased tricuspid lateral annulus velocity (odds ratio, 0.70 implantation [0.48-0.95]; P=0.02). A leftward deviation of interventricular septum was associated with a worse outcome (odds ratio, 3.03 implantation [1.21-13.3]; P=0.01). Mortality and heart failure after LVAD surgery appear to be predominantly determined by echocardiographic evidence of inefficient unloading of the left ventricle and persistence of right ventricular dysfunction. Increased estimated LA pressure and short MDI are associated with worse mid term outcome. Leftward deviation of the septum is associated with worse outcome as well.
Coronary blood flow during percutaneous hemopump in patients at high risk for angioplasty
NASA Astrophysics Data System (ADS)
Geschwind, Herbert J.; Dubois-Rande, Jean Luc; Dupouy, Patrick J.; Larrazet, Fabrice S.; Kvasnicka, Jan; El-Ghalid, Ahmed; Deleuze, Philippe; Loisance, Daniel
1995-05-01
Hemopump is a ventricular assist device which is aimed at improving the management of high- risk patients for PTCA. The aim of the study was to access coronary blood flow velocity during hemopump. The hemopump was inserted percutaneously into the femoral artery. Coronary blood flow was measured with a 12 MHz Doppler-tipped guidewire proximal and distal to the stenosis before, during and after PTCA. Coronary vascular reserve was assessed by intracoronary 12 mg bolus injection of Papaverine. Collateral flow was assessed during balloon occlusion by inverted velocity signals below baseline. Eight patients aged 59 +/- 11 yrs, with unstable angina, a last patent vessel and/or major left ventricular dysfunction (EF < 0.20) had hemopump during PTCA of stenosis (86 +/- 14%) of the LAD (n equals 4) or the LCX (n equals 4). Collateral flow was slightly increased (+25 +/- 18%) by the Hemopump. Hemopump did not strongly affect coronary flow velocity, did not significantly increase collateral flow and increased slightly coronary vascular reserve.
Bridging the gap: Hybrid cardiac echo in the critically ill.
Glaser, Jacob J; Cardarelli, Cassandra; Galvagno, Samuel; Scalea, Thomas M; Murthi, Sarah B
2016-11-01
Point-of-care ultrasound often includes cardiac ultrasound. It is commonly used to evaluate cardiac function in critically ill patients but lacks the specific quantitative anatomic assessment afforded by standard transthoracic echocardiography (TTE). We developed the Focused Rapid Echocardiographic Examination (FREE), a hybrid between a cardiac ultrasound and TTE that places an emphasis on cardiac function rather than anatomy. We hypothesized that data obtained from FREE correlate well with TTE while providing actionable information for clinical decision making. FREE examinations evaluating cardiac function (left ventricular ejection fraction), diastolic dysfunction (including early mitral Doppler flow [E] and early mitral tissue Doppler [E']), right ventricular function, cardiac output, preload (left ventricular internal dimension end diastole), stroke volume, stroke volume variation, inferior vena cava diameter, and inferior vena cava collapse were performed. Patients who underwent both a TTE and FREE on the same day were identified as the cohort, and quantitative measurements were compared. Correlation analyses were performed to assess levels of agreement. A total of 462 FREE examinations were performed, in which 69 patients had both a FREE and TTE. FREE ejection fraction was strongly correlated with TTE (r = 0.89, 95% confidence interval). Left ventricular outflow tract, left ventricular internal dimension end diastole, E, and lateral E' derived from FREE were also strongly correlated with TTE measurements (r = 0.83, r = 0.94, r = 0.77, and r = 0.88, respectively). In 82% of the patients, right ventricular function for FREE was the same as that reported for TTE; pericardial effusion was detected on both examinations in 94% of the cases. No significant valvular anatomy was missed with the FREE examination. Functionally rather than anatomically based hybrid ultrasound examinations, like the FREE, facilitate decision making for critically ill patients. The FREE's functional assessment correlates well with TTE measurements and may be of significant clinical value in critically ill patients, especially when used in remote operating environments where resources are limited. Diagnostic test, level III.
Garcia, M J; Smedira, N G; Greenberg, N L; Main, M; Firstenberg, M S; Odabashian, J; Thomas, J D
2000-01-01
To determine the effect of preload in color M-mode Doppler flow propagation velocity (v(p)). The interpretation of Doppler filling patterns is limited by confounding effects of left ventricular (LV) relaxation and preload. Color M-mode v(p) has been proposed as a new index of LV relaxation. We studied four dogs before and during inferior caval (IVC) occlusion at five different inotropic stages and 14 patients before and during partial cardiopulmonary bypass. Left ventricular (LV) end-diastolic volumes (LV-EDV), the time constant of isovolumic relaxation (tau), left atrial (LA) pre-A and LV end-diastolic pressures (LV-EDP) were measured. Peak velocity during early filling (E) and v(p) were extracted by digital analysis of color M-mode Doppler images. In both animals and humans, LV-EDV and LV-EDP decreased significantly from baseline to IVC occlusion (both p < 0.001). Peak early filling (E) velocity decreased in animals from 56 +/- 21 to 42 +/- 17 cm/s (p < 0.001) without change in v(p) (from 35 +/- 15 to 35 +/- 16, p = 0.99). Results were similar in humans (from 69 +/- 15 to 53 +/- 22 cm/s, p < 0.001, and 37 +/- 12 to 34 +/- 16, p = 0.30). In both species, there was a strong correlation between LV relaxation (tau) and v(p) (r = 0.78, p < 0.001, r = 0.86, p < 0.001). Our results indicate that color M-mode Doppler v(p) is not affected by preload alterations and confirms that LV relaxation is its main physiologic determinant in both animals during varying lusitropic conditions and in humans with heart disease.
NASA Technical Reports Server (NTRS)
Garcia, M. J.; Smedira, N. G.; Greenberg, N. L.; Main, M.; Firstenberg, M. S.; Odabashian, J.; Thomas, J. D.
2000-01-01
OBJECTIVES: To determine the effect of preload in color M-mode Doppler flow propagation velocity (v(p)). BACKGROUND: The interpretation of Doppler filling patterns is limited by confounding effects of left ventricular (LV) relaxation and preload. Color M-mode v(p) has been proposed as a new index of LV relaxation. METHODS: We studied four dogs before and during inferior caval (IVC) occlusion at five different inotropic stages and 14 patients before and during partial cardiopulmonary bypass. Left ventricular (LV) end-diastolic volumes (LV-EDV), the time constant of isovolumic relaxation (tau), left atrial (LA) pre-A and LV end-diastolic pressures (LV-EDP) were measured. Peak velocity during early filling (E) and v(p) were extracted by digital analysis of color M-mode Doppler images. RESULTS: In both animals and humans, LV-EDV and LV-EDP decreased significantly from baseline to IVC occlusion (both p < 0.001). Peak early filling (E) velocity decreased in animals from 56 +/- 21 to 42 +/- 17 cm/s (p < 0.001) without change in v(p) (from 35 +/- 15 to 35 +/- 16, p = 0.99). Results were similar in humans (from 69 +/- 15 to 53 +/- 22 cm/s, p < 0.001, and 37 +/- 12 to 34 +/- 16, p = 0.30). In both species, there was a strong correlation between LV relaxation (tau) and v(p) (r = 0.78, p < 0.001, r = 0.86, p < 0.001). CONCLUSIONS: Our results indicate that color M-mode Doppler v(p) is not affected by preload alterations and confirms that LV relaxation is its main physiologic determinant in both animals during varying lusitropic conditions and in humans with heart disease.
Aggarwal, Sourabh; Xie, Feng; High, Robin; Pavlides, Gregory; Porter, Thomas R
2018-06-01
Although microvascular flow abnormalities have been observed following epicardial recanalization in acute ST-segment elevation myocardial infarction (STEMI), the prevalence and severity of these abnormalities in the current era of rapid percutaneous coronary intervention (PCI) has not been evaluated. The objective of this study was to assess microvascular perfusion (MVP) following successful primary PCI in patients with STEMI and how it affects clinical outcome. In this single-center, retrospective study, 170 patients who successfully underwent emergent PCI for STEMI were assessed using real-time myocardial contrast echocardiography using a continuous infusion of intravenous commercial microbubbles (3% Definity). Three patterns of myocardial contrast replenishment were observed following intermittent high-mechanical index impulses: infarct zone replenishment within 4 sec (normal MVP), delays in contrast replenishment but normal plateau intensity (delayed MVP [dMVP]), and both delays in replenishment and reduced plateau intensity (microvascular obstruction [MVO]). Changes in left ventricular ejection fraction at 6 months and clinical event rate at 12 months (death, recurrent infarction, need for defibrillator placement, or heart failure admission) were compared. Normal MVP was seen in 62 patients (36%), dMVP in 49 (29%), and MVO in 59 (35%). Left anterior descending coronary artery infarct location was the only parameter independently associated with dMVP or MVO, independent of age, cardiac risk factors, door-to-dilation time, pre-PCI Thrombolysis In Myocardial Infarction flow grade, and thrombus burden. A dMVP pattern had a similar reduction in left ventricular ejection fraction as MVO at hospital discharge but had recovery of left ventricular ejection fraction at 6 months and a greater than fourfold lower event rate than the MVO group (P < .001). MVO and dMVP are frequently seen following contemporary successful PCI for STEMI, especially following left anterior descending coronary artery infarction. Despite a similar area at risk, a dMVP pattern has better functional recovery and clinical outcome than MVO. Copyright © 2018 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
Leibundgut, Gregor; Bernheim, Alain M
2010-04-01
The authors report the case of a 77-year-old male patient with sinus rhythm and a first-degree atrioventricular (AV) block who was referred for echocardiographic follow-up 18 years after aortic valve replacement. Left ventricular systolic function as well as the function of the aortic prosthesis was normal. Systolic mitral regurgitation (MR) was virtually absent, but isolated late diastolic MR was detected by colour Doppler imaging. Coincidental to the occurrence of diastolic MR, a second late diastolic forward flow in the pulmonary veins was observed. Therefore, during the prolonged left atrial relaxation caused by first-degree AV block, the left atrial pressure drops below the pressure in both adjacent chambers in late diastole, resulting in both late diastolic MR and a second diastolic pulmonary venous forward flow.
Matuszewska, Gabriela; Marek, Bogdan; Kajdaniuk, Dariusz; Przywara-Chowaniec, Brygida; Jarzab, Jerzy; Jarzab, Barbara
2007-01-01
Patients with differentiated thyroid carcinoma have to undergo radical surgical treatment, which includes total thyreoidectomy, radioiodine therapy and a life-time suppressive therapy with L-thyroxine. The aim of this study was a prospective evaluation of left ventricular hypertrophy during L suppressive-thyroxine treatment in patients treated for differentiated thyroid carcinoma. The examined group comprised 50 patients with differentiated thyroid carcinoma, treated by total thyroidectomy and 131I therapy. Echocardiographic measurements were needed for estimation of left ventricular mass and its index, according to recommendations of American Echocardiography Society. During two-years long suppressive therapy we observed a significant rise in left ventricular mass. In woman group left ventricular mass was increased from 168+/-39 g to 204+/-45 g (p<0.001) and in men from 205+/-60 to 320+/-21 g. Likewise, left ventricular mass index was increased in women group from 96+/-18 g/m(2) to 116+/-25 g/m(2) (p<0.001) and in men group from 107+/-37 g/m(2) to 158+/-28 g/m(2). Simultaneous treatment with bisoprolol caused a regression of left myocardial hypertrophy. Already after 6 months of simultaneous treatment with L-thyroxin and bisoprolol, for left ventricular mass was reduced to normal: in woman 165+/-35 g, and in men to 178+/-38 g. Analogous results were obtained left ventricular mass index. After 6 months it was reduced to 94+/-12 g/m(2) in woman and in men to 132+/-32 g/m(2). 1. In differentiated thyroid cancer patients, treated postoperatively with L-thyroxine suppressive therapy, left ventricular hypertrophy is observed already during the first year of suppressive therapy and progresses during the next year of treatment. 2 Addition of a beta-adrenergic antagonist to suppressive doses of L-thyroxine causes a regression of left ventricular hypertrophy, thus, beta-adrenergic antagonists should be administered in this group of patients.
Said, Sarmad; Cooper, Chad J; Quevedo, Karla; Rodriguez, Emmanuel; Hernandez, German T
2013-01-01
Male, 22 FINAL DIAGNOSIS: Cardiomyopathy Symptoms: Shortness of breath • dispnoea • chest discomfort - Clinical Procedure: Echocardiogram • cardiac MRI Specialty: Cardiology. Challenging differential diagnosis. Non-compaction cardiomyopathy (NCM) is a rare congenital cardiomyopathy characterized by increased trabeculation in one or more segments of the ventricle. The left ventricle is most commonly affected. However, biventricular involvement or right ventricle predominance has also been described. Clinical features of NCM are non-specific and can range from being asymptomatic to symptoms of congestive heart failure, arrhythmia, and systemic thromboembolism. 22-year-old Hispanic male presented with two month history of chest discomfort. Laboratory workup revealed an elevated brain-natriuretic-peptide of 1768 pg/ml. ECG and chest x-ray was nonspecific. Transthoracic echocardiogram revealed prominent trabeculae and spongiform appearance of the left ventricle (LV) with an ejection-fraction of 15-20%; 5 of 9 segments of the LV were trabeculated with deep intertrabecular recesses also involving the right ventricle (RV) with demonstrated blood flow in these recesses on color-doppler. The biventricular spongiform appearance was morphologically suggestive for NCM with involvement of the RV. Confirmatory cardiac MRI was performed, demonstrating excessive trabeculation of the left-ventricular apex and mid-ventricular segments. Hypertrabecularion was exhibited at the apical and lateral wall of the RV. Cardiac catheterization showed an intact cardiac vessel system. The patient was discharged on heart failure treatment and was placed on the heart transplantation list. NCM is a unique disorder resulting in serious and severe complications. The majority of the reported cases describe the involvement of the left ventricle. However, the right ventricle should be taken into careful consideration. The early diagnosis may help to increase the event-free survival.
Liu, Chunna; Liu, Xinyu; Yang, Jing; Duan, Yan; Yao, Hongyue; Li, Fenghua; Zhang, Xia
2015-04-01
Urocortin (UCN) is a newly identified vascular-active peptide that has been shown to reverse cardiovascular remodeling and improve left ventricular (LV) function. The effects and mechanism of urocortin 2 (UCN2) in vivo on the electrical remodeling of left ventricle and the hemodynamics of hypertensive objectives have not been investigated. UCN2 (1 μg/kg/d, 3.5 μg/kg/d or 7 μg/kg/d) was intravenously injected for 2 weeks and its effects on hemodynamics in spontaneously hypertensive rats (SHRs) observed. The whole-cell patch clamp technique was used to explore the effects of UCN2 on the electrical remodeling of left ventricular cardiomyocytes. The flow cytometry method was used to determine the content of fluorescence calcium in myocardium. UCN2 improved the systolic and diastolic function of SHRs as demonstrated by decreased left ventricular systolic pressure (LVSP), left ventricular end diastolic pressure (LVEDP), increased +dp/dtmax and -dp/dtmax and decreased cAMP level. UCN2 inhibited the opening of L-type calcium channel and decreased the calcium channel current of cardiomyocytes. In addition, UCN2 also decreased the contents of fluorescence calcium in SHR myocardium. However, astressin2-B (AST-2B), the antagonist of corticotropin-releasing factor receptor 2 (CRFR2), could reverse the inhibitory effects of UCN2 on calcium channel. UCN2 can modulate electrical remodeling of the myocardium and hemodynamics in an experimental model of SHR via inhibition of L-type calcium channel and CRFR2 in cardiomyocytes. Copyright © 2014 Institute of Pharmacology, Polish Academy of Sciences. Published by Elsevier Urban & Partner Sp. z o.o. All rights reserved.
Cinar, Bahar; Sert, Ahmet; Gokmen, Zeynel; Aypar, Ebru; Aslan, Eyup; Odabas, Dursun
2015-02-01
Previous studies have demonstrated structural changes in the heart and cardiac dysfunction in foetuses with intrauterine growth restriction. There are no available data that evaluated left ventricular dimensions and mass in neonates with symmetric and asymmetric intrauterine growth restriction. Therefore, we aimed to evaluate left ventricular dimensions, systolic functions, and mass in neonates with symmetric and asymmetric intrauterine growth restriction. We also assessed associated maternal risk factors, and compared results with healthy appropriate for gestational age neonates. In all, 62 asymmetric intrauterine growth restriction neonates, 39 symmetric intrauterine growth restriction neonates, and 50 healthy appropriate for gestational age neonates were evaluated by transthoracic echocardiography. The asymmetric intrauterine growth restriction group had significantly lower left ventricular end-systolic and end-diastolic diameters and posterior wall diameter in systole and diastole than the control group. The symmetric intrauterine growth restriction group had significantly lower left ventricular end-diastolic diameter than the control group. All left ventricular dimensions were lower in the asymmetric intrauterine growth restriction neonates compared with symmetric intrauterine growth restriction neonates (p>0.05), but not statistically significant except left ventricular posterior wall diameter in diastole (3.08±0.83 mm versus 3.54 ±0.72 mm) (p<0.05). Both symmetric and asymmetric intrauterine growth restriction groups had significantly lower relative posterior wall thickness (0.54±0.19 versus 0.48±0.13 versus 0.8±0.12), left ventricular mass (9.8±4.3 g versus 8.9±3.4 g versus 22.2±5.7 g), and left ventricular mass index (63.6±29.1 g/m2 versus 54.5±24.4 g/m2 versus 109±28.8 g/m2) when compared with the control group. Our study has demonstrated that although neonates with both symmetric and asymmetric intrauterine growth restriction had lower left ventricular dimensions, relative posterior wall thickness, left ventricular mass, and mass index when compared with appropriate for gestational age neonates, left ventricular systolic functions were found to be preserved. In our study, low socio-economic level, short maternal stature, and low maternal weight were found to be risk factors to develop intrauterine growth restriction. To our knowledge, our study is the first to evaluate left ventricular dimensions, wall thicknesses, mass, and systolic functions in neonates with intrauterine growth restriction and compare results with respect to asymmetric or symmetric subgroups.
Martini, Bortolo; Trevisi, Nicola; Martini, Nicolò; Zhang, Li
2015-01-01
A 43-year-old woman presented to the emergency room with a sustained ventricular tachycardia (VT). ECG showed a QRS in left bundle branch block morphology with inferior axis. Echocardiography, ventricular angiography, and cardiac magnetic resonance imaging (CMRI) revealed a normal right ventricle and a left ventricular diverticulum. Electrophysiology studies with epicardial voltage mapping identified a large fibrotic area in the inferolateral layer of the right ventricular wall and a small area of fibrotic tissue at the anterior right ventricular outflow tract. VT ablation was successfully performed with combined epicardial and endocardial approaches.
Martini, Bortolo; Trevisi, Nicola; Martini, Nicolò; Zhang, Li
2015-01-01
A 43-year-old woman presented to the emergency room with a sustained ventricular tachycardia (VT). ECG showed a QRS in left bundle branch block morphology with inferior axis. Echocardiography, ventricular angiography, and cardiac magnetic resonance imaging (CMRI) revealed a normal right ventricle and a left ventricular diverticulum. Electrophysiology studies with epicardial voltage mapping identified a large fibrotic area in the inferolateral layer of the right ventricular wall and a small area of fibrotic tissue at the anterior right ventricular outflow tract. VT ablation was successfully performed with combined epicardial and endocardial approaches. PMID:26509086
Effect of upright tilt on ventricular/vascular coupling in chronically instrumented primates
NASA Technical Reports Server (NTRS)
Tran, C. C.; Latham, R. D.; Self, D. A.; Fanton, J. W.; White, C. D.; Owens, R. W.
1993-01-01
Studies of the hydraulic loading conditions on the heart in humans, especially pulsatile load, have primarily been limited to the supine state. Therefore, we have chosen a nonhuman primate model, the baboon, to assess left ventricular/vascular coupling in both supine and upright positions. Primate subjects were studied by catheterization under sedation and then after surgical implantation of transducers. This allowed the evaluation of postural stress in the chronically instrumented conscious baboon and then after light dissociative doses of ketamine. Basic hemodynamic variables were evaluated for baboons in supine and upright positions. Fourier analysis was applied to aortic pressure and flow to obtain input and characteristic impedance and the ratio of pulsatile (Wp) to total (Wt) left ventricular power (Wp/Wt). The aortic reflected, or backward, pressure was also calculated. Peripheral resistance increased (P = 0.01) and reflected pressure decreased (17.74 +/- 1.50 vs. 15.21 +/- 2 mmHg; P < 0.01) in upright subjects. Characteristic impedance and Wp/Wt were unchanged. Postoperatively, peripheral resistance increased (2,651 +/- 311 vs. 3,667 +/- 276; P < 0.05) and mean power and Wt decreased (P < 0.01) without changes in reflected pressure. All variables were unchanged after light dissociative doses of ketamine. Thus there is no significant change in efficiency of left ventricular/vascular coupling formulated in terms of Wp/Wt or input impedance with postural stress.
Laflamme, Emilie; Philippon, François; O'Connor, Kim; Sarrazin, Jean-François; Auffret, Vincent; Chauvette, Vincent; Dubois, Michelle; Voisine, Pierre; Bergeron, Sébastien; Sénéchal, Mario
2018-01-01
Guidelines for cardiac resynchronization therapy (CRT) have been established, but there may be a subgroup of patients not identified in these guidelines who may benefit from this therapy. We report a patient with a dynamic left ventricular dyssynchrony and severe mitral regurgitation caused by exercise successfully treated with CRT. Exercise testing should be considered in patients with left ventricular ejection fraction <35% and QRS <130 ms with severe heart failure symptoms that are unexplained by rest echocardiography evaluation in order to rule out ischemia and/or dynamic left ventricular dyssynchrony. In the presence of exercise-induced left ventricular bundle branch block, the implantation of CRT should be contemplated.
Doyle, Mark; Pohost, Gerald M; Bairey Merz, C Noel; Farah, Victor; Shaw, Leslee J; Sopko, George; Rogers, William J; Sharaf, Barry L; Pepine, Carl J; Thompson, Diane V; Rayarao, Geetha; Tauxe, Lindsey; Kelsey, Sheryl F; Biederman, Robert W W
2017-06-01
The Windkessel model of the cardiovascular system, both in its original wind-chamber and flow-pipe form, and in its electrical circuit analog has been used for over a century to modeled left ventricular ejection conditions. Using parameters obtained from aortic flow we formed a Flow Index that is proportional to the impedance of such a "circuit". We show that the impedance varies with ejection fraction (EF) in a manner characteristic of a resonant circuit with multiple resonance points, with each resonance point centrally located in a small range of EF values, i.e., corresponding to multiple contiguous EF bands. Two target populations were used: (I) a development group comprising male and female subjects (n=112) undergoing cardiovascular magnetic resonance (CMR) imaging for a variety of cardiac conditions. The Flow Index was developed using aortic flow data and its relationship to left ventricular EF was shown. (II) An illustration group comprised of female subjects from the Women's Ischemia Syndrome Evaluation (WISE) (n=201) followed for 5 years for occurrence of major adverse cardiovascular events (MACE). Flow data was not available in this group but since the Flow Index was related to the EF we noted the MACE rate with respect to EF. The EFs of the development population covered a wide range (9%-76%) traversing six Flow Index resonance bands. Within each Flow Index resonance band the impedance varied from highly capacitive at the lower range of EF through minimal impedance at resonance, to highly inductive at the higher range of EF, which is characteristic of a resonant circuit. When transitioning from one EF band to a higher band, the Flow Index made a sudden transition from highly inductive to capacitive impedance modes. MACE occurred in 26 (13%) of the WISE (illustration) population. Distance in EF units (Delta center ) from the central location between peaks of MACE activity was derived from EF data and was predictive of MACE rate with an area under the receiver operator curve of 0.73. Of special interest, Delta center was highly predictive of MACE in the sub-set of women with EF >60% (AUC 0.79) while EF was no more predictive than random chance (AUC 0.48). A Flow Index that describes impedance conditions of left ventricular ejection can be calculated using data obtained completely from the ascending aorta. The Flow Index exhibits a periodic variation with EF, and in a separate illustration population the occurrence of MACE was observed to exhibit a similar periodic variation with EF, even in cases of normal EF.
Topilsky, Yan; Oh, Jae K; Shah, Dipesh K; Boilson, Barry A; Schirger, John A; Kushwaha, Sudhir S; Pereira, Naveen L; Park, Soon J
2011-03-01
The purpose of the study was to identify echocardiographic predictors of adverse outcome in patients implanted with continuous-flow left ventricular assist devices (LVAD). Continuous flow LVAD have become part of the standard of care for the treatment of advanced heart failure. However, knowledge of echocardiographic predictors of outcome after LVAD are lacking. Overall, 83 patients received continuous-flow LVAD (HeartMate II, Thoratec Corporation, Pleasanton, California) from February 2007 to June 2010. The LVAD database, containing various echocardiographic parameters, was examined to analyze their influence on in-hospital mortality, a compound cardiac event (in-hospital mortality or acute right ventricular [RV] dysfunction), and long-term mortality. Eight patients died before discharge (operative mortality 9.6%), and another 15 patients were considered to have acute RV dysfunction immediately after surgery. Patients with relatively small left ventricular end-diastolic diameters (<63 mm) had significantly higher risk for in-hospital mortality (odds ratio [OR]: 0.9; 95% confidence interval [CI]: 0.83 to 0.99; p = 0.04) or occurrence of the compound cardiac event (OR: 0.89; 95% CI: 0.84 to 0.95; p < 0.001). The most significant predictor of outcome was the decreased timing interval between the onset and the cessation of tricuspid regurgitation flow corrected for heart rate (TRDc), a surrogate for early systolic equalization of RV and right atrial pressure. Short TRDc predicted in-hospital mortality (OR: 0.85; 95% CI: 0.74 to 0.97; p = 0.01) and the compound cardiac event (OR: 0.83; 95% CI: 0.74 to 0.91; p < 0.0001). Multivariate analysis based on a logistic regression model demonstrated that the accuracy of predicting the 30-day compound adverse outcome was improved with the addition of echocardiographic variables when added to the commonly used hemodynamic or clinical scores. TRDc predicted long-term survival, with adjusted risk ratios of 0.89 for death from any cause (95% CI: 0.83 to 0.96; p = 0.003) and 0.88 for cardiac-related death (95% CI: 0.77 to 0.98; p = 0.03). The presence of either a relatively small left ventricle (<63 mm) or early systolic equalization of RV and right atrial pressure (short TRDc) demonstrated by echocardiography is associated with increased 30-day morbidity and mortality. Prediction of early adverse outcomes by echocardiographic parameters is additive to laboratory or hemodynamic variables. Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Fraser, Katharine H; Zhang, Tao; Taskin, M Ertan; Griffith, Bartley P; Wu, Zhongjun J
2010-01-01
Cannulation is necessary when blood is removed from the body, for example in hemodialysis, cardiopulmonary bypass, blood oxygenators, and ventricular assist devices. Artificial blood contacting surfaces are prone to thrombosis, especially in the presence of stagnant or recirculating flow. In this work, computational fluid dynamics was used to investigate the blood flow fields in three clinically available cannulae (Medtronic DLP 12, 16 and 24 F), used as drainage for pediatric circulatory support, and to calculate parameters which may be indicative of thrombosis potential. The results show that using the 24 F cannula below flow rates of about 0.75 l/min produces hemodynamic conditions which may increase the risk of blood clotting within the cannula. No reasons are indicated for not using the 12 or 16 F cannulae with flow rates between 0.25 and 3.0 l/min. PMID:20400890
Gültekin, Bahadır; Ersoy, Özgür; Akkaya, İlknur; Kayıpmaz, Çağrı; Pirat, Araş; Sezgin, Atilla
2016-11-01
Left ventricular distention can be recognized during the use of venoarterial extracorporeal membrane oxygenation as a key complication. Left ventricular decompression may decrease pulmonary pressure, minimize ventricular distention, and allow myocardial recovery. We applied venoarterial extracorporeal membrane oxygenation to 4 patients while on a wait list for cardiac transplant. Two patients with severe heart failure developed high end-diastolic pressures leading to left ventricular distention. We used atrial venting methods to decrease the pressure. Here, we discussed the strategies to manage ventricular distention by conservative, interventional, and surgical means.
Yokoyama, Yoshimasa; Kawaguchi, Osamu; Kitao, Takashi; Kimura, Taro; Steinseifer, Ulrich; Takatani, Setsuo
2010-09-01
The ventricular performance is dependent on the drainage effect of rotary blood pumps (RBPs) and the performance of RBPs is affected by the ventricular pulsation. In this study, the interaction between the ventricle and RBPs was examined using the pressure-volume (P-V) diagram of the ventricle and dynamic head pressure-bypass flow (H-Q) curves (H, head pressure: arterial pressure minus ventricular pressure vs. Q, bypass flow) of the RBPs. We first investigated the relationships in a mock loop with a passive fill ventricle, followed by validation in ex vivo animal experiments. An apical drainage cannula with a micro-pressure sensor was especially fabricated to obtain ventricular pressure, while three pairs of ultrasonic crystals placed on the heart wall were used to derive ventricular volume. The mock loop-configured ventricular apical-descending aorta bypass revealed that the external work of the ventricle expressed by the area inside the P-V diagrams (EW(Heart) ) correlated strongly with the area inside dynamic H-Q curves (EW(VAD)), with the coefficients of correlation being R² = 0.869 ∼ 0.961. The results in the mock loop were verified in the ex vivo studies using three Shiba goats (10-25 kg in body weight), showing the correlation coefficients of R² = 0.802 ∼ 0.817. The linear regression analysis indicated that the increase in the bypass flow reduced pulsatility in the ventricle expressed in EW(Heart) as well as in EW(VAD) . Experimental results, both mock loop and animal studies, showed that the interaction between cardiac external work and H-Q performance of RBPs can be expressed by the relationships "EW(Heart) versus EW(VAD) ." The pulsatile nature of the native heart can be expressed in the area underneath the H-Q curves of RBPs EW(VAD) during left heart bypass indicating the status of the level of assistance by RBPs and the native heart function. © 2010, Copyright the Authors. Artificial Organs © 2010, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Pérez-Lahiguera, Francisco J; Rodilla, Enrique; Costa, Jose A; Gonzalez, Carmen; Martín, Joaquin; Pascual, Jose M
2012-12-01
The purpose of the present study was to assess the relationship of central and peripheral blood pressure to left ventricular mass. Cross-sectional study that included 392 never treated hypertensive individuals. Measurement of office, 24-h ambulatory, and central blood pressure (obtained using applanation tonometry) and determination of left ventricular mass by echocardiography were performed in all patients. In a multiple regression analysis, with adjustment for age, gender and metabolic syndrome, 24-h blood pressure was more closely related to ventricular mass than the respective office and central blood pressures. Systolic blood pressures always exhibited a higher correlation than diastolic blood pressures in all 3 determinations. The correlation between left ventricular mass index and 24-h systolic blood pressure was higher than that of office (P<.002) or central systolic blood pressures (P<.002). Changes in 24-h systolic blood pressure caused the greatest variations in left ventricular mass index (P<.001). In our population of untreated middle-aged hypertensive patients, left ventricular mass index is more closely related to 24-h ambulatory blood pressure than to office or central blood pressure. Central blood pressure does not enable us to better identify patients with left ventricular hypertrophy. Copyright © 2012 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.
Younan, Duraid; Beasley, T Mark; Pigott, David C; Gibson, C Blayke; Gullett, John P; Richey, Jeffrey; Pittet, Jean-Francois; Zaky, Ahmed
2017-10-11
Conventional echocardiographic technique for assessment of volume status and cardiac contractility utilizes left ventricular end-diastolic area (LVEDA) and fractional area of change (FAC), respectively. Our goal was to find a technically reliable yet faster technique to evaluate volume status and contractility by measuring left ventricular end-diastolic diameter (LVEDD) and fractional shortening (FS) in a cohort of mechanically ventilated trauma and burn patients using hemodynamic transesophageal echocardiographic (hTEE) monitoring. Retrospective chart review performed at trauma/burn intensive care unit (TBICU). Data on 88 mechanically ventilated surgical intensive care patients cared for between July 2013 and July 2015 were reviewed. Initial measurements of LVEDA, left ventricular end-systolic area (LVESA) and FAC were collected. Post-processing left ventricular end-systolic (LVESD) and end-diastolic diameters (LVEDD) were measured and fractional shortening (FS) was calculated. Two orthogonal measurements of LV diameter were obtained in transverse (Tr) and posteroanterior (PA) orientation. There was a significant correlation between transverse and posteroanterior left ventricular diameter measurements in both systole and diastole. In systole, r = 0.92, p < 0.01 for LVESD-Tr (mean 23.47 mm, SD ± 6.77) and LVESD-PA (mean 24.84 mm, SD = 8.23). In diastole, r = 0.80, p < 0.01 for LVEDD-Tr (mean 37.60 mm, SD ± 6.45), and LVEDD-PA diameters (mean 42.24 mm, SD ± 7.97). Left ventricular area (LVEDA) also significantly correlated with left ventricular diameter LVEDD-Tr (r = 0.84, p < 0.01) and LVEDD-PA (r = 0.90, p < 0.01). Both transverse and PA measurements of fractional shortening were significantly (p < 0.0001) and similarly correlated with systolic function as measured by FAC. Bland-Altman analyses also indicated that the assessment of fractional shortening using left ventricular posteroanterior diameter measurement shows agreement with FAC. Left ventricular diameter measurements are a reliable and technically feasible alternative to left ventricular area measurements in the assessment of cardiac filling and systolic function.
Mulloy, Daniel P.; Bhamidipati, Castigliano M.; Stone, Matthew L.; Ailawadi, Gorav; Kron, Irving L.; Kern, John A.
2012-01-01
Objectives Orthotopic heart transplantation is the standard of care for end-stage heart disease. Left ventricular assist device implantation offers an alternative treatment approach. Left ventricular assist device practice has changed dramatically since the 2008 Food and Drug Administration approval of the HeartMate II (Thoratec, Pleasanton, Calif), but at what societal cost? The present study examined the cost and efficacy of both treatments over time. Methods All patients who underwent either orthotopic heart transplantation (n = 9369) or placement of an implantable left ventricular assist device (n = 6414) from 2005 to 2009 in the Nationwide Inpatient Sample were selected. The trends in treatment use, mortality, and cost were analyzed. Results The incidence of orthotopic heart transplantation increased marginally within a 5-year period. In contrast, the annual left ventricular assist device implantation rates nearly tripled. In-hospital mortality from left ventricular assist device implantation decreased precipitously, from 42% to 17%. In-hospital mortality for orthotopic heart transplantation remained relatively stable (range, 3.8%–6.5%). The mean cost per patient increased for both orthotopic heart transplantation and left ventricular assist device placement (40% and 17%, respectively). With the observed increase in both device usage and cost per patient, the cumulative Left ventricular assist device cost increased 232% within 5 years (from $143 million to $479 million). By 2009, Medicare and Medicaid were the primary payers for nearly one half of all patients (orthotopic heart transplantation, 45%; left ventricular assist device, 51%). Conclusions Since Food and Drug Administration approval of the HeartMate II, mortality after left ventricular assist device implantation has decreased rapidly, yet has remained greater than that after orthotopic heart transplantation. The left ventricular assist device costs have continued to increase and have been significantly greater than those for orthotopic heart transplantation. Because of the evolving healthcare economics climate, with increasing emphasis on the costs and comparative effectiveness, a concerted effort at LVAD cost containment and judicious usage is essential to preserve the viability of this invaluable treatment. PMID:23246055
Design and numeric evaluation of a novel axial-flow left ventricular assist device.
Toptop, Koral; Kadipasaoglu, Kamuran A
2013-01-01
Virtual design characteristics and performance of the first Turkish axial-flow left ventricular assist device (LVAD) are presented, with emphasis on rotor geometry. The patented rotor design includes a central flow channel carved inside the main block, which carries permanent magnets. A concentric rotor-stator gap minimizes the distance between respective magnets, improving electromagnetic efficiency and creating a second blood pathway. Dual sets of three helical blades, placed on the shaft and external surface of the rotor block, ensure unidirectionality. Hemodynamic performance was tested with computational fluid dynamics (CFD); and rotor-blade geometry was optimized, to maximize overall efficiency d and minimize backflow and wall shear stresses. For a shaft radius of 4.5 mm, rotor blade height of 2.5 mm, and blade inlet and exit metal angles of 67° and 32°, pump operation at the nominal head-flow combination (5 L/min and 100.4 mm Hg) was achieved at a rotor speed of 10,313 rpm. At the nominal point, backflow as percent of total flow was 7.29 and 29.87% at rotor inlet and exit, respectively; overall hydraulic efficiency reached 21.59%; and maximum area-averaged shroud shear was 520 Pa. Overall efficiency peaked at 24.07% for a pump flow of 6.90 L/min, and averaged at 22.57% within the flow range of 4-8 L/min. We concluded that the design satisfies initial rotor design criteria, and that continued studies with diffuser optimization and transient flow analysis are warranted.
Kiernan, Michael S; Grandin, E Wilson; Brinkley, Marshall; Kapur, Navin K; Pham, Duc Thinh; Ruthazer, Robin; Rame, J Eduardo; Atluri, Pavan; Birati, Edo Y; Oliveira, Guilherme H; Pagani, Francis D; Kirklin, James K; Naftel, David; Kormos, Robert L; Teuteberg, Jeffrey J; DeNofrio, David
2017-10-01
To investigate preimplant risk factors associated with early right ventricular assist device (RVAD) use in patients undergoing continuous-flow left ventricular assist device (LVAD) surgery. Patients in the Interagency Registry for Mechanically Assisted Circulatory Support who underwent primary continuous-flow-LVAD surgery were examined for concurrent or subsequent RVAD implantation within 14 days of LVAD. Risk factors for RVAD implantation and the combined end point of RVAD or death within 14 days of LVAD were assessed with stepwise logistic regression. We compared survival between patients with and without RVAD using Kaplan-Meier method and Cox proportional hazards modeling. Of 9976 patients undergoing continuous-flow-LVAD implantation, 386 patients (3.9%) required an RVAD within 14 days of LVAD surgery. Preimplant characteristics associated with RVAD use included interagency registry for mechanically assisted circulatory support patient profiles 1 and 2, the need for preoperative extracorporeal membrane oxygenation or renal replacement therapy, severe preimplant tricuspid regurgitation, history of cardiac surgery, and concomitant procedures other than tricuspid valve repair at the time of LVAD. Hemodynamic determinants included elevated right atrial pressure, reduced pulmonary artery pulse pressure, and reduced stroke volume. The final model demonstrated good performance for both RVAD implant (area under the curve, 0.78) and the combined end point of RVAD or death within 14 days (area under the curve, 0.73). Compared with patients receiving an isolated LVAD, patients requiring RVAD had decreased 1- and 6-month survival: 78.1% versus 95.8% and 63.6% versus 87.9%, respectively ( P <0.0001 for both). The need for RVAD implantation after LVAD is associated with indices of global illness severity, markers of end-organ dysfunction, and profiles of hemodynamic instability. © 2017 American Heart Association, Inc.
Kim, Won Ho; Hong, Tae Hee; Byun, Joung Hun; Kim, Jong Woo; Kim, Sung Hwan; Moon, Sung Ho; Park, Hyun Oh; Choi, Jun Young; Yang, Jun Ho; Jang, In Seok; Lee, Chung Eun; Yun, Jeong Hee
In refractory cardiogenic shock, veno-arterial extracorporeal membrane oxygenation (ECMO) can be initiated. Although left heart decompression can be accomplished by insertion of a left atrial (LA) or left ventricular (LV) cannula using a percutaneous pigtail catheter, the venting flow rate according to catheter size and ECMO flow rate is unknown. We developed an artificial ECMO circuit. One liter saline bag with its pressure set to 20 mm Hg was connected to ECMO to mimic LV failure. A pigtail catheter was inserted into the 1 L saline bag to simulate LV unloading. For each pigtail catheter size (5-8 Fr) and ECMO flow rate (2.0-4.0 L/min), the moving distance of an air bubble that was injected through a three-way stopcock was measured in the arterial pressure line between the pigtail catheter and ECMO inflow limb. The flow rate was then calculated. We obtained the following equation to estimate the pigtail catheter flow rate.Pigtail vent catheter flow rate (ml/min) = 8×ECMOflow rate(L /min)+9×pigtail catheter size(Fr)- 57This equation would aid in designing of a further study to determine optimal venting flow rate. To achieve optimal venting flow, our equation would enable selection of an adequate catheter size.
Tesic, Milorad; Djordjevic-Dikic, Ana; Beleslin, Branko; Trifunovic, Danijela; Giga, Vojislav; Marinkovic, Jelena; Petrovic, Olga; Petrovic, Milan; Stepanovic, Jelena; Dobric, Milan; Vukcevic, Vladan; Stankovic, Goran; Seferovic, Petar; Ostojic, Miodrag; Vujisic-Tesic, Bosiljka
2013-07-01
To evaluate, by noninvasive coronary flow velocity reserve (CFVR), whether patients with asymmetric hypertrophic cardiomyopathy (HC), with or without left ventricular outflow tract obstruction, demonstrate significant regional differences of CFVR. We evaluated 61 patients with HC (27 men; mean age 49 ± 16 years), including 20 patients with hypertrophic obstructive cardiomyopathy (HOCM) and 41 patients without obstruction (HCM). The control group included 20 age- and sex-matched subjects. Transthoracic Doppler echocardiography CFVR of the left anterior descending coronary artery (LAD) and the posterior descending coronary artery (PD) were performed, including calculation of relative CFVR as the ratio between CFVR LAD and CFVR PD. Compared with the controls, all the patients with HC had lower CFVR LAD (2.12 ± 0.53 vs 3.34 ± 0.67; P < .001) and CFVR PD (2.29 ± 0.49 vs 3.21 ± 0.65; P < .001). CFVR LAD in HOCM group in comparison with the HCM group was significantly lower (1.93 ± 0.42 vs 2.22 ± 0.55; P = .047), due to higher basal diastolic coronary flow velocities (0.40 ± 0.09 vs 0.33 ± 0.07 m/sec; P = .002), with similar hyperemic diastolic flow velocities (0.71 ± 0.16 vs 0.76 ± 0.19 m/sec; P = .330), respectively. There was no significant difference in CFVR PD between patients with HOCM and those with HCM (2.33 ± 0.46 vs 2.27 ± 0.50; P = .636), respectively. Relative CFVR was lower in the HOCM group compared with the HCM group (0.84 ± 0.16 vs 0.98 ± 0.14; P = .001). By multivariable regression analysis, left ventricular outflow tract gradient was the independent predictor of CFVR LAD (B = -0.24; P = .008) and relative CFVR (B = -0.34; P = .016). CFVR LAD and relative CFVR were significantly lower in patients with HOCM compared with patients with HCM. Regional differences of CFVR are present only in patients with significant left ventricular outflow tract obstruction, which suggests that obstruction per se, by increasing wall stress in basal conditions, leads to higher basal diastolic coronary flow velocities and results in lower CFVR in LAD compared with PD. Copyright © 2013 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.
Xi, Er-Ping; Zhu, Jian; Zhu, Shui-Bo; Yin, Gui-Lin; Liu, Yong; Dong, Yong-Qiang; Zhang, Yu; Xia, Feng
2012-11-01
Ventricular septal defects resulting from post-traumatic cardiac injury are very rare. Percutaneous closure has emerged as a method for treating this disorder. We wish to report our experience in three patients who underwent percutaneous closure of a post-traumatic ventricular septal defect with a patent ductus arteriosus occluder. We treated three patients with post-traumatic ventricular septal defects caused by stab wounds with knives. After the heart wound was repaired, patient examinations revealed ventricular septal defects with pulmonary/systemic flow ratios (Qp/Qs) of over 1.7. The post-traumatic ventricular septal defects were closed percutaneously with a patent ductus arteriosus occluder (Lifetech Scientific (Shenzhen) Co., LTD, Guangdong, China) utilizing standard techniques. Post-operative transthoracic echocardiography revealed no residual left-to-right shunt and indicated normal ventricular function. In addition, 320-slice computerized tomography showed that the occluder was well placed and exhibited normal morphology. Our experiences indicate that closure of a post-traumatic ventricular septal defect using a patent ductus arteriosus occluder is feasible, safe, and effective.
Xi, Er-Ping; Zhu, Jian; Zhu, Shui-Bo; Yin, Gui-Lin; Liu, Yong; Dong, Yong-Qiang; Zhang, Yu; Xia, Feng
2012-01-01
OBJECTIVE: Ventricular septal defects resulting from post-traumatic cardiac injury are very rare. Percutaneous closure has emerged as a method for treating this disorder. We wish to report our experience in three patients who underwent percutaneous closure of a post-traumatic ventricular septal defect with a patent ductus arteriosus occluder. METHODS: We treated three patients with post-traumatic ventricular septal defects caused by stab wounds with knives. After the heart wound was repaired, patient examinations revealed ventricular septal defects with pulmonary/systemic flow ratios (Qp/Qs) of over 1.7. The post-traumatic ventricular septal defects were closed percutaneously with a patent ductus arteriosus occluder (Lifetech Scientific (Shenzhen) Co., LTD, Guangdong, China) utilizing standard techniques. RESULTS: Post-operative transthoracic echocardiography revealed no residual left-to-right shunt and indicated normal ventricular function. In addition, 320-slice computerized tomography showed that the occluder was well placed and exhibited normal morphology. CONCLUSION: Our experiences indicate that closure of a post-traumatic ventricular septal defect using a patent ductus arteriosus occluder is feasible, safe, and effective. PMID:23184204
Abd-El-Aziz, Tarek A
2012-01-01
The aim of this study was to compare 3 different available methods for estimating left ventricular end-diastolic pressure (LVEDP) noninvasively in patients with coronary artery disease and preserved left ventricular ejection fraction (EF). We used 3 equations for noninvasive estimation of LVEDP: The equation of Mulvagh et al., LVEDP(1) = 46 - 0.22 (IVRT) - 0.10 (AFF) - 0.03 (DT) - (2 ÷ E/A) + 0.05 MAR; the equation of Stork et al., LVEDP(2) = 1.06 + 15.15 × Ai/Ei; and the equation of Abd-El-Aziz, LVEDP(3) = [0.54 (MABP) × (1 - EF)] - 2.23. ( A, A-wave velocity; AFF, atrial filling fraction; Ai, time velocity integral of A wave; DT, deceleration time; E, E-wave velocity; Ei, time velocity integral of E wave; IVRT, isovolumic relaxation time; MABP, mean arterial blood pressure; MAR, time from termination of mitral flow to the electrocardiographic R wave; Ti, time velocity integral of total wave.) LVEDP measured by catheterization was correlated with LVEDP(1) (r = 0.52, P < 0.001), LVEDP(2) (r = 0.31, P < 0.05), and LVEDP(3) (r = 0.81, P < 0.001). The equation described by Abd-El-Aziz, LVEDP = [0.54 MABP × (1 - EF)] - 2.23, appears to be the most accurate, reliable, and easily applied method for estimating LVEDP noninvasively in patients with preserved left ventricular ejection fraction and an LVEDP < 20 mm Hg. Copyright © 2012 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.
Della Mea, Paolo; Lupia, Mario; Bandolin, Valentina; Guzzon, Samuele; Sonino, Nicoletta; Vettor, Roberto; Fallo, Francesco
2005-01-01
Adiponectin is an adipocyte-derived protein with insulin-sensitizing and antiatherogenic properties. Failure to decrease blood pressure (BP) normally during night in hypertensive patients has been independently associated with left ventricular hypertrophy. We examined the relationship between adiponectin levels, insulin sensitivity, and left ventricular structure in 40 newly diagnosed never-treated patients with essential hypertension, including 20 patients with a normal night-time pressure decrease (ie, dippers) and 20 patients with BP persistently elevated throughout the 24-h period (ie, nondippers). All subjects had grade 1-2 hypertension, aged 18 to 65 years, no diabetes mellitus, no obesity, no hyperlipidemia, and no cardiopulmonary, renal, or hepatic disease. The two groups of patients were similar for age, sex, body mass index, and had no differences for clinic, 24-h, and diurnal BP, and 24-h, diurnal, and nocturnal heart rate, as well as glucose, total cholesterol, and triglyceride levels. Plasma insulin and homeostasis model assessment (HOMA index) were higher (P < .01), and adiponectin levels were lower (P < .005) in nondippers than in dippers. Adiponectin correlated inversely with HOMA index and insulin levels (r = -0.58, and r = -0.62, respectively, P < .001) in the entire population. Nondippers showed left ventricular mass, relative wall thickness, and measure of early and late diastolic peak flow velocity ratio similar to those of dippers. In the absence of major cardiovascular risk factors, nondipper essential hypertensive patients show more prominent insulin resistance and lower adiponectin compared to dippers. Therapeutic modulation of adiponectin or insulin resistance might provide additional benefit to the conventional antihypertensive treatment.
Gao, Hang; Bijnens, Nathalie; Coisne, Damien; Lugiez, Mathieu; Rutten, Marcel; D'hooge, Jan
2015-01-01
Despite the availability of multiple ultrasound approaches to left ventricular (LV) flow characterization in two dimensions, this technique remains in its childhood and further developments seem warranted. This article describes a new methodology for tracking the 2-D LV flow field based on ultrasound data. Hereto, a standard speckle tracking algorithm was modified by using a dynamic kernel embedding Navier-Stokes-based regularization in an iterative manner. The performance of the proposed approach was first quantified in synthetic ultrasound data based on a computational fluid dynamics model of LV flow. Next, an experimental flow phantom setup mimicking the normal human heart was used for experimental validation by employing simultaneous optical particle image velocimetry as a standard reference technique. Finally, the applicability of the approach was tested in a clinical setting. On the basis of the simulated data, pointwise evaluation of the estimated velocity vectors correlated well (mean r = 0.84) with the computational fluid dynamics measurement. During the filling period of the left ventricle, the properties of the main vortex obtained from the proposed method were also measured, and their correlations with the reference measurement were also calculated (radius, r = 0.96; circulation, r = 0.85; weighted center, r = 0.81). In vitro results at 60 bpm during one cardiac cycle confirmed that the algorithm properly measures typical characteristics of the vortex (radius, r = 0.60; circulation, r = 0.81; weighted center, r = 0.92). Preliminary qualitative results on clinical data revealed physiologic flow fields. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Ghista, D. N.; Hamid, M. S.
1977-01-01
The three-dimensional left ventricular chamber geometrical model is developed from single plane cineangiocardiogram. This left ventricular model is loaded by an internal pressure monitored by cardiac catheterization. The resulting stresses in the left ventricular model chamber's wall are determined by computerized finite element procedure. For the discretization of this left ventricular model structure, a 20-node, isoparametric finite element is employed. The analysis and formulation of the computerised procedure is presented in the paper, along with the detailed algorithms and computer programs. The procedure is applied to determine the stresses in a left ventricle at an instant, during systole. Next, a portion (represented by a finite element) of this left ventricular chamber is simulated as being infarcted by making its active-state modulus value equal to its passive-state value; the neighbouring elements are shown to relieve the 'infarcted' element of stress by themselves taking on more stress.
Successful weaning of a left ventricular assist device implanted for ischemic heart failure.
Beurtheret, Sylvain; Mordant, Pierre; Pavie, Alain; Leprince, Pascal
2010-10-01
We report the case of a patient stabilized under extra-corporeal membrane oxygenation after a refractory cardiogenic shock following myocardial infarction. Persistent left ventricular failure required secondary implantation of the left ventricular assist device (LVAD) HeartMate II. LVAD succeeded in the gradual recovery of myocardial contractility, allowing weaning of the device five months after implantation. Simultaneously, the patient beneficiated from coronary revascularization and resumed normal activity. This case emphasizes potential late recoveries after myocardial infarction complicated by left ventricular failure.
Robotic assisted excision of a left ventricular myxoma.
Hassan, Mohammed; Smith, J Michael
2012-01-01
We present a rare case of left ventricular myxoma discovered incidentally in an asymptomatic 16-year old male. The patient underwent the appropriate work-up and a robotic-assisted excision of the mass. The patient had an uneventful recovery and was discharged home at postoperative day 3. To our knowledge, this is the first case of robotic-assisted left ventricular myxoma excision in the literature. Robotic-assisted surgery of left ventricular myxomas is a safe and feasible method of excision.
dos Santos Moreira, Carlos; Serejo, Fátima; Alcântara, Paula; Ramalhinho, Vítor; Braz Nogueira, J
2015-05-01
An exaggerated accumulation of type I and type III fibrillar collagens occurs throughout the free wall and interventricular septum of patients with primary hypertension and left ventricular hypertrophy (LVH). In the present study the serum concentration of procollagen type III amino terminal peptide (PIIIP) was measured to determine the value of this peptide as a potential marker of ventricular fibrosis in hypertensive patients, particularly those with LVH. The study population consisted of patients with never-treated mild to moderate essential hypertension and 30 normotensive control subjects. Clinical, echocardiographic, electrocardiographic and biochemical parameters were assessed in all patients. Heart rate, body mass index and levels of blood pressure were increased in hypertensives, particularly those with LVH, compared to normotensive controls. Posterior wall thickness, left ventricular (LV) mass and LV mass index, and serum PIIIP concentration were also increased in hypertensives, with significant differences between the two hypertensive groups. The ratio between maximal early and late transmitral flow velocity measured during diastole was lower in hypertensives, particularly those with LVH, than in normotensive controls. The increase in PIIIP indicates that type III collagen synthesis increases in hypertensives, particularly those with LVH, implying that alterations in the heart in hypertension are the result not solely of hypertrophied LV muscle, but also of increased collagen deposition within the ventricular wall and around the coronary vessels. Thus, measurement of serum PIIIP could be a practical and useful tool in the non-invasive assessment of myocardial remodeling in hypertension. Copyright © 2014 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.
Zhong, Beihua
2009-01-01
Activation of the protease-activated receptor 2 (PAR2) or the transient receptor potential vanilloid type 1 (TRPV1) channels expressed in cardiac sensory afferents containing calcitonin gene-related peptide (CGRP) and/or substance P (SP) has been proposed to play a protective role in myocardial ischemia-reperfusion (I/R) injury. However, the interaction between PAR2 and TRPV1 is largely unknown. Using gene-targeted TRPV1-null mutant (TRPV1−/−) or wild-type (WT) mice, we test the hypothesis that TRPV1 contributes to PAR2-mediated cardiac protection via increasing the release of CGRP and SP. Immunofluorescence labeling showed that TRPV1 coexpressed with PAR2, PKC-ε, or PKAc in cardiomyocytes, cardiac blood vessels, and perivascular nerves in WT but not TRPV1−/− hearts. WT or TRPV1−/− hearts were Langendorff perfused with the selective PAR2 agonist, SLIGRL, in the presence or absence of various antagonists, followed by 35 min of global ischemia and 40 min of reperfusion (I/R). The recovery rate of coronary flow, the maximum rate of left ventricular pressure development, left ventricular end-diastolic pressure, and left ventricular developed pressure were evaluated after I/R. SLIGRL improved the recovery of hemodynamic parameters, decreased lactate dehydrogenase release, and reduced the infarct size in both WT and TRPV1−/− hearts (P < 0.05). The protection of SLIGRL was significantly surpassed for WT compared with TRPV1−/− hearts (P < 0.05). CGRP8–37, a selective CGRP receptor antagonist, RP67580, a selective neurokinin-1 receptor antagonist, PKC-ε V1–2, a selective PKC-ε inhibitor, or H-89, a selective PKA inhibitor, abolished SLIGRL protection by inhibiting the recovery of the rate of coronary flow, maximum rate of left ventricular pressure development, and left ventricular developed pressure, and increasing left ventricular end-diastolic pressure in WT but not TRPV1−/− hearts. Radioimmunoassay showed that SLIGRL increased the release of CGRP and SP in WT but not TRPV1−/− hearts (P < 0.05), which were prevented by PKC-ε V1–2 and H-89. Thus our data show that PAR2 activation improves cardiac recovery after I/R injury in WT and TRPV1−/− hearts, with a greater effect in the former, suggesting that PAR2-mediated protection is TRPV1 dependent and independent, and that dysfunctional TRPV1 impairs PAR2 action. PAR2 activation of the PKC-ε or PKA pathway stimulates or sensitizes TRPV1 in WT hearts, leading to the release of CGRP and SP that contribute, at least in part, to PAR2-induced cardiac protection against I/R injury. PMID:19812353
Koh, Angela S; Murthy, Venkatesh L; Sitek, Arkadiusz; Gayed, Peter; Bruyere, John; Wu, Justina; Di Carli, Marcelo F; Dorbala, Sharmila
2015-09-01
Longstanding uncontrolled atherogenic risk factors may contribute to left atrial (LA) hypertension, LA enlargement (LAE) and coronary vascular dysfunction. Together they may better identify risk of major adverse cardiac events (MACE). The aim of this study was to test the hypothesis that chronic LA hypertension as assessed by LAE modifies the relationship between coronary vascular function and MACE. In 508 unselected subjects with a normal clinical (82)Rb PET/CT, ejection fraction ≥40 %, no prior coronary artery disease, valve disease or atrial fibrillation, LAE was determined based on LA volumes estimated from the hybrid perfusion and CT transmission scan images and indexed to body surface area. Absolute myocardial blood flow and global coronary flow reserve (CFR) were calculated. Subjects were systematically followed-up for the primary end-point - MACE - a composite of all-cause death, myocardial infarction, hospitalization for heart failure, stroke, coronary artery disease progression or revascularization. During a median follow-up of 862 days, 65 of the subjects experienced a composite event. Compared with subjects with normal LA size, subjects with LAE showed significantly lower CFR (2.25 ± 0.83 vs. 1.95 ± 0.80, p = 0.01). LAE independently and incrementally predicted MACE even after accounting for clinical risk factors, medication use, stress left ventricular ejection fraction, stress left ventricular end-diastolic volume index and CFR (chi-squared statistic increased from 30.9 to 48.3; p = 0.001). Among subjects with normal CFR, those with LAE had significantly worse event-free survival (risk adjusted HR 5.4, 95 % CI 2.3 - 12.8, p < 0.0001). LAE and reduced CFR are related but distinct cardiovascular adaptations to atherogenic risk factors. LAE is a risk marker for MACE independent of clinical factors and left ventricular volumes; individuals with LAE may be at risk of MACE despite normal coronary vascular function.
Lafci, Gokhan; Cagli, Kerim; Korkmaz, Kemal; Turak, Osman; Uzun, Alper; Yalcinkaya, Adnan; Diken, Adem; Gunertem, Eren; Cagli, Kumral
2014-01-01
Subvalvular apparatus preservation is an important concept in mitral valve replacement (MVR) surgery that is performed to remedy mitral regurgitation. In this study, we sought to determine the effects of papillary muscle repositioning (PMR) on clinical outcomes and echocardiographic left ventricular function in rheumatic mitral stenosis patients who had normal left ventricular systolic function. We prospectively assigned 115 patients who were scheduled for MVR surgery with mechanical prosthesis to either PMR or MVR-only groups. Functional class and echocardiographic variables were evaluated at baseline and at early and late postoperative follow-up examinations. All values were compared between the 2 groups. The PMR group consisted of 48 patients and the MVR-only group of 67 patients. The 2 groups’ baseline characteristics and surgery-related factors (including perioperative mortality) were similar. During the 18-month follow-up, all echocardiographic variables showed a consistent improvement in the PMR group; the mean left ventricular ejection fraction deteriorated significantly in the MVR-only group. Comparison during follow-up of the magnitude of longitudinal changes revealed that decreases in left ventricular end-diastolic and end-systolic diameters and in left ventricular sphericity indices, and increases in left ventricular ejection fractions, were significantly higher in the PMR group than in the MVR-only group. This study suggests that, in patients with rheumatic mitral stenosis and preserved left ventricular systolic function, the addition of papillary muscle repositioning to valve replacement with a mechanical prosthesis improves left ventricular dimensions, ejection fraction, and sphericity index at the 18-month follow-up with no substantial undesirable effect on the surgery-related factors. PMID:24512397
Zhao, Linshuang; Xu, Chunyan; Xu, Jinling
2014-01-01
To explore the relationship between the autoantibodies against the β1 and AT1 receptors and left ventricular dilatation in patients with type 2 diabetes (T2DM). The autoantibodies against the β1 and angiotensin II type 1 (AT1) receptors of T2DM patients with and without hypertension were screened by ELISA. Multiple logistic regression was used to analyze the risk factors for left ventricular dilatation. The reversing effect of left ventricular dilatation was evaluated after receptor blocker treatment. The positive rates of autoantibodies against the β1 and AT1 receptors (43.0 and 44.1%, respectively) in T2DM patients with hypertension were significantly higher than those in normotensive patients (16.0 and 10.4%, respectively; all p < 0.01). Furthermore, among T2DM patients with hypertension, the positive rates (61.4 and 64.9%, respectively) in patients with left ventricular dilatation were remarkably higher than those with normal left ventricular dimensions (34.4 and 36.1%, respectively; all p < 0.01). The presence of β1 receptor antibody and AT1 receptor antibody were risk factors for left ventricular dilatation (p < 0.05). The curative effect of metoprolol tartrate and valsartan in reversing left ventricular hypertrophy in the group positive for autoantibodies was much better than in the negative group. The findings show that autoantibodies against the β1 and AT1 receptors may play a role in predicting left ventricular dilatation in T2DM patients in combination with hypertension. Metoprolol tartrate and valsartan are effective and safe in the treatment of these patients. © 2014 S. Karger AG, Basel.
Growth of left ventricular mass with military basic training in army recruits.
Batterham, Alan M; George, Keith P; Birch, Karen M; Pennell, Dudley J; Myerson, Saul G
2011-07-01
Exercise-induced left ventricular hypertrophy is well documented, but whether this occurs merely in line with concomitant increases in lean body mass is unclear. Our aim was to model the extent of left ventricular hypertrophy associated with increased lean body mass attributable to an exercise training program. Cardiac and whole-body magnetic resonance imaging was performed before and after a 10-wk intensive British Army basic training program in a sample of 116 healthy Caucasian males (aged 17-28 yr). The within-subjects repeated-measures allometric relationship between lean body mass and left ventricular mass was modeled to allow the proper normalization of changes in left ventricular mass for attendant changes in lean body mass. To linearize the general allometric model (Y=aXb), data were log-transformed before analysis; the resulting effects were therefore expressed as percent changes. We quantified the probability that the true population increase in normalized left ventricular mass was greater than a predefined minimum important difference of 0.2 SD, assigning a probabilistic descriptive anchor for magnitude-based inference. The absolute increase in left ventricular mass was 4.8% (90% confidence interval=3.5%-6%), whereas lean body mass increased by 2.6% (2.1%-3.0%). The change in left ventricular mass adjusted for the change in lean body mass was 3.5% (1.9%-5.1%), equivalent to an increase of 0.25 SD (0.14-0.37). The probability that this effect size was greater than or equal to our predefined minimum important change of 0.2 SD was 0.78-likely to be important. After correction for allometric growth rates, left ventricular hypertrophy and lean body mass changes do not occur at the same magnitude in response to chronic exercise.
Different effects of prolonged exercise on the right and left ventricles.
Douglas, P S; O'Toole, M L; Hiller, W D; Reichek, N
1990-01-01
To examine the functional consequences of the greater increase in right ventricular work with exercise, the effects of prolonged exercise on the right and left heart chambers were compared in 41 athletes before, at the finish (13 min) and after recovery (28 h) from the Hawaii Ironman Triathlon (3.9 km swim, 180.2 km bike ride, 42.2 km run). Two-dimensional and Doppler echocardiograms were analyzed for left and right atrial and ventricular areas at end-diastole and end-systole, right and left ventricular inflow velocities and mitral and tricuspid regurgitation. After exercise, left ventricular and left and right atrial sizes were reduced, whereas right ventricular size increased (diastole: 21.4 to 24.2 cm2; systole: 15.8 to 18.2 cm2; p less than 0.01). The emptying fraction of all chambers was unchanged. Left but not right ventricular inflow showed an increase in peak velocity of rapid filling, whereas both atrial systolic velocities increased (26 to 38 cm/s tricuspid; 38 to 54 cm/s mitral; both p less than 0.01). Overall, the right ventricular early to atrial velocity ratio was reduced after exercise (1.56 to 1.17; p less than 0.05) and the left ventricular pattern was unchanged. The prevalence of tricuspid regurgitation was statistically unchanged (86% to 52%), although that of mitral regurgitation was greatly reduced (76% to 0%). Changes in all variables returned toward prerace values during recovery. Thus, in highly trained athletes, prolonged exercise causes differing responses of the right and left ventricles. These differences may be due to changes in right ventricular function, shape or compliance.
Left ventricular assist devices as destination therapy: a new look at survival.
Park, Soon J; Tector, Alfred; Piccioni, William; Raines, Edward; Gelijns, Annetine; Moskowitz, Alan; Rose, Eric; Holman, William; Furukawa, Satoshi; Frazier, O Howard; Dembitsky, Walter
2005-01-01
The REMATCH trial compared the use of left ventricular assist devices with optimal medical management for patients with end-stage heart failure. When the trial met its primary end point criteria in July 2001, left ventricular assist device therapy was shown to significantly improve survival and quality of life. With extended follow-up, 2 critical questions emerge: (1) Did these benefits persist, and (2) did outcomes improve over the course of the trial, given the evolving nature of the technology? We analyzed survival in this randomized trial by using the product-limit method of Kaplan and Meier. Changes in the benefits of therapy were analyzed by examining the effect of the enrollment period. The survival rates for patients receiving left ventricular assist devices (n = 68) versus patients receiving optimal medical management (n = 61) were 52% versus 28% at 1 year and 29% versus 13% at 2 years ( P = .008, log-rank test). As of July 2003, 11 patients were alive on left ventricular assist device support out of a total 16 survivors (including 3 patients receiving optimal medical management who crossed over to left ventricular assist device therapy). There was a significant improvement in survival for left ventricular assist device-supported patients who enrolled during the second half of the trial compared with the first half ( P = .03). The Minnesota Living with Heart Failure scores improved significantly over the course of the trial. The extended follow-up confirms the initial observation that left ventricular assist device therapy renders significant survival and quality-of-life benefits compared with optimal medical management for patients with end-stage heart failure. Furthermore, we observed an improvement in the survival of patients receiving left ventricular assist devices over the course of the trial, suggesting the effect of greater clinical experience.
Long-term results after left ventricular aneurysmectomy.
Otterstad, J E; Christensen, O; Levorstad, K; Nitter-Hauge, S
1981-01-01
Twenty-six patients (21 men and five women) with a mean age of 54.8 years have been reinvestigated nine to 62 months (mean 29.7) after left ventricular aneurysmectomy. Preoperatively left ventricular angiography disclosed an anterior aneurysm in all cases, which was large in 15 (57%) and small to medium in 11 (42%). At follow-up a large residual aneurysm was found in five (19%), a small to medium one in 13 (50%), and akinesia without aneurysm in eight (31%). The sum of ST elevation (sigma ST) in praecordial leads in the electrocardiogram was reduced from a mean value of 11.2 mm to 7.7 mm. In no patient did ST segments return to normal after operation. Preoperatively, mean sigma ST was identical in patients with large and with small to medium aneurysms. At reinvestigation mean sigma ST was identical in patients with large and with small to medium residual aneurysms as well as in patients with akinesia. Left ventricular end-diastolic pressure before angiography was reduced from a mean value of 21.5 mm to 15.1 mmHg and after angiography from 26.7 mm to 21.1 mmHg. Progression of coronary artery stenoses was a characteristic finding in patients whose left ventricular end-diastolic pressures did not return to normal. These patients had a longer follow-up time than those with no progression of coronary disease, who all showed an improvement in left ventricular end-diastolic pressure. Six patients who had coronary bypass grafting performed had unchanged left ventricular end-diastolic pressures at follow-up. The results indicate that progression of coronary artery disease may be responsible for an eventual further deterioration in left ventricular function after aneurysmectomy. Additional bypass grafting did not result in improved left ventricular function. PMID:6971647
Cardiovascular function during sustained +G/z/ stress
NASA Technical Reports Server (NTRS)
Erickson, H. H.; Sandler, H.; Stone, H. L.
1976-01-01
The development of aerospace systems capable of very high levels of positive vertical accelerators stress has created a need for a better understanding of the cardiovascular responses to acceleration. Using a canine model, the heart and cardiovascular system were instrumented to continuously measure coronary blood flow, cardiac output, left ventricular and aortic root pressure, and oxygen saturation in the aorta, coronary sinus, and right ventricle. The animals were exposed to acceleration profiles up to +6 G, 120 s at peak G; a seatback angle of 45 deg was simulated in some experiments. Radiopaque contrast medium was injected to visualize the left ventricular chamber, coronary vasculature, aorta, and branches of the aorta. The results suggest mechanisms responsible for arrhythmias which may occur, and subendocardial hemorrhage which has been reported in other animals.
Experimental myocardial infarction
Kumar, Raj; Joison, Julio; Gilmour, David P.; Molokhia, Farouk A.; Pegg, C. A. S.; Hood, William B.
1971-01-01
The hemodynamic effects of tachycardia induced by atrial pacing were investigated in left ventricular failure of acute and healing experimental myocardial infarction in 20 intact, conscious dogs. Myocardial infarction was produced by gradual inflation of a balloon cuff device implanted around the left anterior descending coronary artery 10-15 days prior to the study. 1 hr after acute myocardial infarction, atrial pacing at a rate of 180 beats/min decreased left ventricular end-diastolic pressure from 19 to 8 mm Hg and left atrial pressure from 17 to 12 mm Hg, without change in cardiac output. In the healing phase of myocardial infarction 1 wk later, atrial pacing decreased left ventricular end-diastolic pressure from 17 to 9 mm Hg and increased the cardiac output by 37%. This was accompanied by evidence of peripheral vasodilation. In two dogs with healing anterior wall myocardial infarction, left ventricular failure was enhanced by partial occlusion of the circumflex coronary artery. Both the dogs developed pulmonary edema. Pacing improved left ventricular performance and relieved pulmonary edema in both animals. In six animals propranolol was given after acute infarction, and left ventricular function deteriorated further. However the pacing-induced augmentation of cardiac function was unaltered and, hence, is not mediated by sympathetics. The results show that the spontaneous heart rate in left ventricular failure of experimental canine myocardial infarction may be less than optimal and that maximal cardiac function may be achieved at higher heart rates. Images PMID:4395910
Cork, David P; Adamson, Robert; Gollapudi, Raghava; Dembitsky, Walter; Jaski, Brian
2018-02-01
Mitral regurgitation commonly improves after implantation of a left ventricular assist device without concomitant valvular repair owing to the mechanical unloading of the left ventricle. However, the development (or persistence) of significant mitral regurgitation after implantation of a left ventricular assist device is associated with adverse clinical events. We present a case of a left ventricular assist device patient who successfully underwent a percutaneous MitraClip procedure for repair of persistent late postoperative mitral insufficiency with demonstrable clinical and hemodynamic improvement. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Mantini, Cesare; Caulo, Massimo; Marinelli, Daniele; Chiacchiaretta, Piero; Tartaro, Armando; Cotroneo, Antonio Raffaele; Di Giammarco, Gabriele
2018-04-13
To investigate and describe the distribution of aortic and cerebral blood flow (CBF) in patients with severe valvular aortic stenosis (AS) before and after aortic valve bypass (AVB) surgery. We enrolled 10 consecutive patients who underwent AVB surgery for severe AS. Cardiovascular magnetic resonance imaging (CMR) and brain magnetic resonance imaging were performed as baseline before surgery and twice after surgery. Quantitative flow measurements were obtained using 1.5-T magnetic resonance imaging (MRI) scanner phase-contrast images of the ascending aorta, descending thoracic aorta (3 cm proximally and distally from the conduit-to-aorta anastomosis), and ventricular outflow portion of the conduit. The evaluation of CBF was performed using 3.0-T MRI scanner arterial spin labeling (ASL) through sequences acquired at the gray matter, dorsal default-mode network, and sensorimotor levels. Conduit flow, expressed as the percentage of total antegrade flow through the conduit, was 63.5 ± 8% and 67.8 ± 7% on early and mid-term postoperative CMR, respectively (P < .05). Retrograde perfusion from the level of the conduit insertion in the descending thoracic aorta toward the aortic arch accounted for 6.9% of total cardiac output and 11% of total conduit flow. We did not observe any significant reduction in left ventricular stroke volume at postoperative evaluation compared with preoperative evaluation (P = .435). No differences were observed between preoperative and postoperative CBF at the gray matter, dorsal default-mode network, and sensorimotor levels (P = .394). After AVB surgery in patients with severe AS, cardiac output is split between the native left ventricular outflow tract and the apico-aortic bypass, with two-thirds of the total antegrade flow passing through the latter and one-third passing through the former. In our experience, CBF assessment confirms that the flow redistribution does not jeopardize cerebral blood supply. Copyright © 2018 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Cannula Tip With Integrated Volume Sensor for Rotary Blood Pump Control: Early-Stage Development.
Cysyk, Joshua; Newswanger, Ray; Popjes, Eric; Pae, Walter; Jhun, Choon-Sik; Izer, Jenelle; Weiss, William; Rosenberg, Gerson
2018-05-10
The lack of direct measurement of left ventricular unloading is a significant impediment to the development of an automatic speed control system for continuous-flow left ventricular assist devices (cf-LVADs). We have developed an inlet cannula tip for cf-LVADs with integrated electrodes for volume sensing based on conductance. Four platinum-iridium ring electrodes were installed into grooves on a cannula body constructed from polyetheretherketone (PEEK). A sinusoidal current excitation waveform (250 μA pk-pk, 50 kHz) was applied across one pair of electrodes, and the conductance-dependent voltage was sensed across the second pair of electrodes. The conductance catheter was tested in an acute ovine model (n = 3) in conjunction with the HeartMate II rotary blood pump to provide circulatory support and unload the ventricle. Echocardiography was used to measure ventricular size during pump support for verification for the conductance measurements. The conductance measurements correlated linearly with the echocardiography dimension measurements more than the full range of pump support from minimum support to suction. This cannula tip will enable the development of automatic control systems to optimize pump support based on a real-time measurement of ventricular size.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Willerson, J.T.
1979-01-01
Nuclear Cardiology is a well-written, concise compendium of chapters that covers a wide range of topics in nuclear cardiology. Each chapter has been contributed by one or more recognized experts in the field, and the work is thoroughly referened. The physics and physiology of nuclear cardiology, myocardial imaging with /sup 201/Tl and /sup 99m/Tc pyrophosphate, left ventricular and right ventricular function, measurement of coronary blood flow with /sup 133/Xe, and microspheres are discussed, and there are chapters on metabolic imaging with positron emitters and on transmission computerized tomography of the heart.
Annular subvalvular left ventricular aneurysm in Bahia, Brazil.
Guimarães, A C; Filho, A S; Esteves, J P; Abreu, W N; Vinhaes, L A; de Almeida Souza, J A; Machado, A
1976-01-01
Two cases of left ventricular aneurysm, a 16-year-old black boy and a 23-year-old white girl, from Bahia, Brazil, are presented. In both patients there was enlargement of the cardiac silhouette and a prominent bulge of the left inferior border. On the right oblique view a ring of calcium at the ventricular opening of the aneurysms was visualized. A left ventriculogram showed a huge aneurysm in the first case and a bulge on the lateral wall of the left ventricle in the other. Cardiac catheterization showed a rise in left and right ventricular end-diastolic pressures and in the mean pulmonary artery pressure. In the first case the contour of the right ventricular pressure curve showed a restrictive pattern. The similarities of these aneurysms with the annular submitral type described in young black Africans are stressed. Images PMID:973882
Annular subvalvular left ventricular aneurysm in Bahia, Brazil.
Guimarães, A C; Filho, A S; Esteves, J P; Abreu, W N; Vinhaes, L A; de Almeida Souza, J A; Machado, A
1976-10-01
Two cases of left ventricular aneurysm, a 16-year-old black boy and a 23-year-old white girl, from Bahia, Brazil, are presented. In both patients there was enlargement of the cardiac silhouette and a prominent bulge of the left inferior border. On the right oblique view a ring of calcium at the ventricular opening of the aneurysms was visualized. A left ventriculogram showed a huge aneurysm in the first case and a bulge on the lateral wall of the left ventricle in the other. Cardiac catheterization showed a rise in left and right ventricular end-diastolic pressures and in the mean pulmonary artery pressure. In the first case the contour of the right ventricular pressure curve showed a restrictive pattern. The similarities of these aneurysms with the annular submitral type described in young black Africans are stressed.
Bybee, Kevin A; Kara, Tomas; Prasad, Abhiram; Lerman, Amir; Barsness, Greg W; Wright, R Scott; Rihal, Charanjit S
2004-12-07
The transient left ventricular apical ballooning syndrome, also known as takotsubo cardiomyopathy, is characterized by transient wall-motion abnormalities involving the left ventricular apex and mid-ventricle in the absence of obstructive epicardial coronary disease. In this paper, we review case series that report on patients with the transient left ventricular apical ballooning syndrome to better characterize patients presenting with the syndrome. We identified 7 case series that reported on at least 5 consecutive patients with the transient left ventricular apical ballooning syndrome. The syndrome more often affects postmenopausal women (82% to 100%) (mean age, 62 to 75 years). Patients commonly present with ST-segment elevation in the precordial leads, chest pain, relatively minor elevation of cardiac enzyme and biomarker levels, and transient apical systolic left ventricular dysfunction despite the absence of obstructive epicardial coronary disease. An episode of emotional or physiologic stress frequently precedes presentation with the syndrome. The in-hospital mortality rate seems to be low, as does the risk for recurrence.
Bavo, A M; Pouch, A M; Degroote, J; Vierendeels, J; Gorman, J H; Gorman, R C; Segers, P
2017-01-04
As the intracardiac flow field is affected by changes in shape and motility of the heart, intraventricular flow features can provide diagnostic indications. Ventricular flow patterns differ depending on the cardiac condition and the exploration of different clinical cases can provide insights into how flow fields alter in different pathologies. In this study, we applied a patient-specific computational fluid dynamics model of the left ventricle and mitral valve, with prescribed moving boundaries based on transesophageal ultrasound images for three cardiac pathologies, to verify the abnormal flow patterns in impaired hearts. One case (P1) had normal ejection fraction but low stroke volume and cardiac output, P2 showed low stroke volume and reduced ejection fraction, P3 had a dilated ventricle and reduced ejection fraction. The shape of the ventricle and mitral valve, together with the pathology influence the flow field in the left ventricle, leading to distinct flow features. Of particular interest is the pattern of the vortex formation and evolution, influenced by the valvular orifice and the ventricular shape. The base-to-apex pressure difference of maximum 2mmHg is consistent with reported data. We used a CFD model with prescribed boundary motion to describe the intraventricular flow field in three patients with impaired diastolic function. The calculated intraventricular flow dynamics are consistent with the diagnostic patient records and highlight the differences between the different cases. The integration of clinical images and computational techniques, therefore, allows for a deeper investigation intraventricular hemodynamics in patho-physiology. Copyright © 2016 Elsevier Ltd. All rights reserved.
Jani, Ylber; Kamberi, Ahmet; Xhunga, Sotir; Pocesta, Bekim; Ferati, Fatmir; Lala, Dali; Zeqiri, Agim; Rexhepi, Atila
2015-01-01
Objective: To assess the influence of type 2 DM and gender, on the QT dispersion, Tpeak-Tend dispersion of ventricular repolarization, in patients with sub-clinic left ventricular diastolic dysfunction of the heart. Background: QT dispersion, that reflects spatial inhomogeneity in ventricular repolarization, Tpeak-Tend dispersion, this on the other hand reflects transmural inhomogeneity in ventricular repolarization, that is increased in an early stage of cardiomyopathy, and in patients with left ventricular diastolic dysfunction, as well. The left ventricular diastolic dysfunction, a basic characteristic of diabetic heart disease (diabetic cardiomyopathy), that developes earlier than systolic dysfunction, suggests that diastolic markers might be sensitive for early cardiac injury. It is also demonstrated that gender has complex influence on indices of myocardial repolarization abnormalities such as QT interval and QT dispersion. Material and methods: We performed an observational study including 300 diabetic patients with similar epidemiological-demographic characteristics recruited in our institution from May 2009 to July 2014, divided into two groups. Demographic and laboratory echocardiographic data were obtained, twelve lead resting electrocardiography, QT, QTc, Tpeak-Tend-intervals and dispersion, were determined manually, and were compared between various groups. For statistical analysis a t-test, X2 test, and logistic regression are used according to the type of variables. A p value <0.05 was considered statistically significant for a confidence interval of 95%. Results: QTc max. interval, QTc dispersion and Tpeak-Tend dispersion, were significantly higher in diabetic group with subclinical LV (left ventricular) diastolic dysfunction, than in diabetic group with normal left ventricular diastolic function (445.24±14.7 ms vs. 433.55±14.4 ms, P<0.000; 44.98±18.78 ms vs. 32.05±17.9 ms, P<0.000; 32.60±1.6 ms vs. 17.46±2.0 ms, P<0.02. Prolonged QTc max. interval was found in 33% of patients, indiabetic group with subclinical left ventricular diastolic dysfunction vs. 13.3% of patients in diabetic group with normal left ventricular diastolic function, (Chi-square: 16.77, P<0.0001). A prolonged QTc dispersion, was found in 40.6% of patients, in diabetic group with subclinical left ventricular diastolic dysfunction vs. 20% of patients in diabetic group with normal left ventricular diastolic function Chi-square: 14.11, P<0.0002). A prolonged dispersion of Tpeak-Tend interval was found in 24% of patients in diabetic group with subclinical left ventricular diastolic dysfunction vs. 13.3% of patients in diabetic group with normal left ventricular diastolic function (Chi-square: 12.00, P<0.005). Females in diabetic group with subclinical left ventricular diastolic dysfunction in comparison with males in diabetic group with subclinical left ventricular diastolic dysfunction, have a significantly prolonged: mean QTc max. interval (23.3% vs. 10%, Chisquare: 12.0, P<0.005), mean QTc dispersion (27.3% vs. 13.3%, Chi-square: 10.24, P<0.001), mean Tpeak-Tend interval (10% vs. 3.3%, Chi-square: 5.77, P<0.01), mean Tpek-Tend dispersion (16.6% vs. 6.6%, Chi-square: 8.39, P<0.003). Conclusion: The present study has shown that influences of type 2 diabetes and gender in diabetics with sub-clinical left-ventricular diastolic dysfunction are reflected in a set of electrophysiological parameters that indicate a prolonged and more heterogeneous repolarization than in diabetic patients with normal diastolic function. In addition, it demonstrates that there exist differences between diabetic females with sub-clinic LV dysfunction and those with diabetes and normal LV function in the prevalence of increased set of electrophysiological parameters that indicate a prolonged and more heterogeneous repolarization. PMID:26550530
Jani, Ylber; Kamberi, Ahmet; Xhunga, Sotir; Pocesta, Bekim; Ferati, Fatmir; Lala, Dali; Zeqiri, Agim; Rexhepi, Atila
2015-01-01
To assess the influence of type 2 DM and gender, on the QT dispersion, Tpeak-Tend dispersion of ventricular repolarization, in patients with sub-clinic left ventricular diastolic dysfunction of the heart. QT dispersion, that reflects spatial inhomogeneity in ventricular repolarization, Tpeak-Tend dispersion, this on the other hand reflects transmural inhomogeneity in ventricular repolarization, that is increased in an early stage of cardiomyopathy, and in patients with left ventricular diastolic dysfunction, as well. The left ventricular diastolic dysfunction, a basic characteristic of diabetic heart disease (diabetic cardiomyopathy), that developes earlier than systolic dysfunction, suggests that diastolic markers might be sensitive for early cardiac injury. It is also demonstrated that gender has complex influence on indices of myocardial repolarization abnormalities such as QT interval and QT dispersion. We performed an observational study including 300 diabetic patients with similar epidemiological-demographic characteristics recruited in our institution from May 2009 to July 2014, divided into two groups. Demographic and laboratory echocardiographic data were obtained, twelve lead resting electrocardiography, QT, QTc, Tpeak-Tend-intervals and dispersion, were determined manually, and were compared between various groups. For statistical analysis a t-test, X(2) test, and logistic regression are used according to the type of variables. A p value <0.05 was considered statistically significant for a confidence interval of 95%. QTc max. interval, QTc dispersion and Tpeak-Tend dispersion, were significantly higher in diabetic group with subclinical LV (left ventricular) diastolic dysfunction, than in diabetic group with normal left ventricular diastolic function (445.24±14.7 ms vs. 433.55±14.4 ms, P<0.000; 44.98±18.78 ms vs. 32.05±17.9 ms, P<0.000; 32.60±1.6 ms vs. 17.46±2.0 ms, P<0.02. Prolonged QTc max. interval was found in 33% of patients, indiabetic group with subclinical left ventricular diastolic dysfunction vs. 13.3% of patients in diabetic group with normal left ventricular diastolic function, (Chi-square: 16.77, P<0.0001). A prolonged QTc dispersion, was found in 40.6% of patients, in diabetic group with subclinical left ventricular diastolic dysfunction vs. 20% of patients in diabetic group with normal left ventricular diastolic function Chi-square: 14.11, P<0.0002). A prolonged dispersion of Tpeak-Tend interval was found in 24% of patients in diabetic group with subclinical left ventricular diastolic dysfunction vs. 13.3% of patients in diabetic group with normal left ventricular diastolic function (Chi-square: 12.00, P<0.005). Females in diabetic group with subclinical left ventricular diastolic dysfunction in comparison with males in diabetic group with subclinical left ventricular diastolic dysfunction, have a significantly prolonged: mean QTc max. interval (23.3% vs. 10%, Chisquare: 12.0, P<0.005), mean QTc dispersion (27.3% vs. 13.3%, Chi-square: 10.24, P<0.001), mean Tpeak-Tend interval (10% vs. 3.3%, Chi-square: 5.77, P<0.01), mean Tpek-Tend dispersion (16.6% vs. 6.6%, Chi-square: 8.39, P<0.003). The present study has shown that influences of type 2 diabetes and gender in diabetics with sub-clinical left-ventricular diastolic dysfunction are reflected in a set of electrophysiological parameters that indicate a prolonged and more heterogeneous repolarization than in diabetic patients with normal diastolic function. In addition, it demonstrates that there exist differences between diabetic females with sub-clinic LV dysfunction and those with diabetes and normal LV function in the prevalence of increased set of electrophysiological parameters that indicate a prolonged and more heterogeneous repolarization.
Effects of increasing left ventricular filling pressure in patients with acute myocardial infarction
Russell, Richard O.; Rackley, Charles E.; Pombo, Jaoquin; Hunt, David; Potanin, Constantine; Dodge, Harold T.
1970-01-01
Left ventricular performance in 19 patients with acute myocardial infarction has been evaluated by measuring left ventricular response in terms of cardiac output, stroke volume, work, and power to progressive elevation of filling pressure accomplished by progressive expansion of blood volume with rapid infusion of low molecular weight dextran. Such infusion can elevate the cardiac output, stroke volume, work, and power and thus delineate the function of the left ventricle by Frank-Starling function curves. Left ventricular filling pressure in the range of 20-24 mm Hg was associated with the peak of the curves and when the filling pressure exceeded this range, the curves became flattened or decreased. An increase in cardiac output could be maintained for 4 or more hr. Patients with a flattened function curve had a high mortality in the ensuing 8 wk. The function curve showed improvement in myocardial function during the early convalescence. When left ventricular filling pressure is monitored directly or as pulmonary artery end-diastolic pressure, low molecular weight dextran provides a method for assessment of left ventricular function. Images PMID:5431663
The left ventricle in aortic stenosis--imaging assessment and clinical implications.
Călin, Andreea; Roşca, Monica; Beladan, Carmen Cristiana; Enache, Roxana; Mateescu, Anca Doina; Ginghină, Carmen; Popescu, Bogdan Alexandru
2015-04-29
Aortic stenosis has an increasing prevalence in the context of aging population. In these patients non-invasive imaging allows not only the grading of valve stenosis severity, but also the assessment of left ventricular function. These two goals play a key role in clinical decision-making. Although left ventricular ejection fraction is currently the only left ventricular function parameter that guides intervention, current imaging techniques are able to detect early changes in LV structure and function even in asymptomatic patients with significant aortic stenosis and preserved ejection fraction. Moreover, new imaging parameters emerged as predictors of disease progression in patients with aortic stenosis. Although proper standardization and confirmatory data from large prospective studies are needed, these novel parameters have the potential of becoming useful tools in guiding intervention in asymptomatic patients with aortic stenosis and stratify risk in symptomatic patients undergoing aortic valve replacement.This review focuses on the mechanisms of transition from compensatory left ventricular hypertrophy to left ventricular dysfunction and heart failure in aortic stenosis and the role of non-invasive imaging assessment of the left ventricular geometry and function in these patients.
Feng, Cheng; Chen, Lixin; Li, Jian; Wang, Jiangtao; Dong, Fajin; Xu, Jinfeng
2017-01-01
To compare a full-automated software to quantify 3D transthoracic echocardiography namely, 3DE-HM (three-dimensional echocardiography HeartModel, Philips Healthcare) with the traditional manual quantitative method (3DE-manual) for assessing volumes of left atrial and ventricular volumes, and left ventricular ejection fraction (LVEF). 3D full volume images acquired from 156 subjects were collected and divided into 3 groups, which include 70 normal control cases (Group A), 17 patients with left ventricular remodeling after acute myocardial infarction (AMI) (Group B), and 69 patients with left atrial remodeling secondary to hypertension (Group C). The 3DE-HM method was used to quantify left ventricular end-diastolic volume (LVEDV), left ventricular end-systolic volume (LVESV), left atrial end-systolic volume (LAESV), and left ventricular ejection fraction (LVEF), respectively. The results were compared with those obtained with the 3DE-manual method for correlation and consistency analyses. The reproducibility of the 3DE-HM method was also evaluated. There was a high correlation between LVEDV, LVESV, LAESV and LVEF values obtained with the 3DE-HM method and those obtained using the 3DE-manual method (r = 0.72 to 0.97). The correlation was strongest for Group B, patients with left ventricular remodeling post-AMI also demonstrated the greatest degree of morphologic changes. There was a significant difference in all parameters measured with the 3DE-HM method in different groups (P < 0.05). The difference in the measurements of LVEDV and LVESV between the two methods was greatest in patients in Group B compared with patients with hypertension-induced left ventricular remodeling (Group C) and in normal controls (Group A) (P < 0.05). Lastly, the difference in the measurement of LAESV between the two methods was greater in patients with hypertension-induced left ventricular remodeling (Group C) than that in the control group (Group A) (P < 0.05). The post-processing time of the 3DE-HM data was significantly shorter than that using the 3DE-manual method (P < 0.05). There was no significant variability in repeated measurements at different time points using the 3DE-HM method either between subjects in different groups or within the same subject. 3DE-HM is a quick and feasible method for left ventricular quantification and is clinically applicable for evaluating patients with left atrial and left ventricular remodeling.
Elias, Merrill F; Sullivan, Lisa M; Elias, Penelope K; D'Agostino, Ralph B; Wolf, Philip A; Seshadri, Sudha; Au, Rhoda; Benjamin, Emelia J; Vasan, Ramachandran S
2007-03-01
The purpose of this study was to determine whether echocardiographic left ventricular mass is related to cognitive performance beyond casual blood pressure adjusting for the influence of other vascular risk factors. We used multivariable regression analyses to relate left ventricular mass assessed at a routine examination (1995-1998) to measures of cognitive ability obtained routinely (1998-2001) in 1673 Framingham Offspring Study participants (56% women; mean age: 57 years) free from stroke, transient ischemic attack, and dementia. We adjusted for the following covariates hierarchically: (1) age, education, sex, body weight, height, interval between left ventricular mass measurement and neuropsychological testing (basic model); (2) basic model+blood pressure+treatment for hypertension; and (3) basic model+blood pressure+treatment for hypertension+vascular risk factors and prevalent cardiovascular disease. For the basic model, left ventricular mass was inversely associated with abstract reasoning (similarities), visual-spatial memory and organization, and verbal memory. For the basic model+blood pressure+treatment for hypertension, left ventricular mass was inversely associated with similarities and visual-spatial memory and organization. For the basic+blood pressure+treatment for hypertension+risk factors+cardiovascular disease model, no significant associations were observed. Echocardiographic left ventricular mass is associated with cognitive performance beyond casual and time-averaged systolic blood pressure, but this association is attenuated and rendered nonsignificant with additional adjustment for cardiovascular risk factors and cardiovascular disease, thus suggesting that these variables play an important role in mediating the association between left ventricular mass and cognition.
Garcia, Santiago; Akbar, Muhammad S; Ali, Syed S; Kamdar, Forum; Tsai, Michael Y; Duprez, Daniel A
2010-09-03
Left ventricular hypertrophy adversely affects outcomes in patients with hypertension. Whether N-terminal pro B-type natriuretic peptide (NT-proBNP) adds incremental prognostic information in patients with hypertension and left ventricular hypertrophy (LVH) is not well established. We aimed to study the prognostic value of NT-proBNP in hypertensive patients with LVH. Echocardiography was performed in 232 patients (mean age 61±15, 102 males, 130 females) for the diagnosis of left ventricular hypertrophy. Left ventricular mass was measured according to The American Society of Echocardiography guidelines. A blood sample was taken for NT-proBNP determination. NT-proBNP levels were analyzed in quartiles after log transformation. Long term survival was established by review of electronic medical records. Arterial hypertension was present in 130 patients (56%) and left ventricular hypertrophy was present in 105 patients (45%). In patients with left ventricular hypertrophy, NT-proBNP levels predicted long term survival (Chi-square=10, p=0.01). After adjusting by age, presence of coronary artery disease, ejection fraction, diabetes status, and hypertension; patients in highest NT pro-BNP quartile were twice as likely to die when compared to patients in the lowest NT-ptoBNP quartile (OR=2.2, 95% CI=1.0-4.6, p=0.03). NT-proBNP is an independent predictor of survival in patients with hypertension and increased left ventricular mass. Copyright © 2009 Elsevier B.V. All rights reserved.
Kamphuis, Vivian P; Westenberg, Jos J M; van der Palen, Roel L F; van den Boogaard, Pieter J; van der Geest, Rob J; de Roos, Albert; Blom, Nico A; Roest, Arno A W; Elbaz, Mohammed S M
2018-01-05
The aim of the current study was to assess the scan-rescan reproducibility of left ventricular (LV) kinetic energy (KE), viscous energy loss (EL) and vorticity during diastole from four-dimensional flow magnetic resonance imaging (4D flow MRI) in healthy subjects. Twelve volunteers (age 27 ± 3 years) underwent whole-heart 4D flow MRI twice in one session. In-scan consistency was evaluated by correlation between KE and EL. EL index was computed to measure the amount of EL relative to KE over diastole. Scan-rescan analysis was performed to test reproducibility of volumetric measurements of KE, EL, EL index and vorticity in the LV over early (E) and late (A) diastolic filling. In-scan consistency between KE and EL was strong-excellent (E-filling scan1: r = 0.92, P < 0.001; scan2: ρ = 0.96, P < 0.001 and A-filling scan1: ρ = 0.87, P < 0.001; scan2: r = 0.99, P < 0.001). For the majority of subjects (10 out of 12), KE and EL measures showed good to strong reproducibility. However, with a wide range of agreement [intraclass correlation (ICC): 0.64-0.95] and coefficients of variation (CV) ≤ 25%. EL index showed strong reproducibility for all 12 subjects with a strong ICC (0.94, P < 0.001) and a CV of 9%. Scan-rescan reproducibility of volumetric vorticity showed good-excellent ICCs (0.83-0.95) with CVs ≤ 11%. In conclusion, the current study shows strong-excellent in-scan consistency and overall good agreement between scans for 4D flow MRI assessment of left ventricular kinetic energy, energy loss and vorticity over diastole. However, substantial differences between the scans were also found in some parameters in two out of twelve subjects. Strong reproducibility was found in the dimensionless EL index , which measures the amount of viscous energy loss relative to the average kinetic energy over diastole.
Kazmaier, S; Weyland, A; Buhre, W; Stephan, H; Rieke, H; Filoda, K; Sonntag, H
1998-10-01
Variation of the arterial carbon dioxide partial pressure (PaCO2) is not uncommon in anesthetic practice. However, little is known about the myocardial consequences of respiratory alkalosis and acidosis, particularly in patients with coronary artery disease. The aim of the current study was to investigate the effects of variation in PaCO2 on myocardial blood flow (MBF), metabolism, and systemic hemodynamics in patients before elective coronary artery bypass graft surgery. In 10 male anesthetized patients, measurements of MBF, myocardial contractility, metabolism, and systemic hemodynamics were made in a randomized sequence at PaCO2 levels of 30, 40, and 50 mmHg, respectively. The MBF was measured using the Kety-Schmidt technique with argon as a tracer. End-diastolic left ventricular pressure and the maximal increase of left ventricular pressure were assessed using a manometer-tipped catheter. The cardiac index significantly changed with varying PaCO2 levels (hypocapnia, - 9%; hypercapnia, 13%). This reaction was associated with inverse changes in systemic vascular resistance index levels. The MBF significantly increased by 15% during hypercapnia, whereas no change was found during hypocapnia. Myocardial oxygen and glucose uptake and the maximal increase of left ventricular pressure were not affected by varying PaCO2 levels. In anesthetized patients with coronary artery disease, short-term variations in PaCO2 have significant effects on MBF but do not influence global myocardial oxygen and glucose uptake. Changes in systemic hemodynamics associated with respiratory alkalosis and acidosis are caused by changes in systemic vascular resistance rather than by alterations in myocardial contractility.
Ngiam, Jinghao Nicholas; Kuntjoro, Ivandito; Tan, Benjamin Y Q; Sim, Hui-Wen; Kong, William K F; Yeo, Tiong-Cheng; Poh, Kian-Keong
2017-11-01
Controversy surrounds the prognosis and management of patients with paradoxical low-flow severe aortic stenosis (AS) with preserved left ventricular ejection fraction (LVEF). It was not certain if patients in a particular flow category remained in the same category as disease progressed. We investigated whether there were switches in categories and if so, their predictors. Consecutive subjects (n = 203) with isolated severe AS and paired echocardiography (>180 days apart) were studied. They were divided into 4 groups, based on their flow categories and if they progressed on subsequent echocardiography to switch or remain in the same flow category. Univariate analyses of clinical and echocardiographic parameters identified predictors of these changes in flow category. One hundred eighteen were normal flow (SVI ≥ 35 mL/m 2 ), while 85 were low flow on index echocardiography. In the patients with normal flow, 33% switched to low flow. This was associated with higher valvuloarterial impedance (Zva, P < .001) and lower systemic arterial compliance (SAC, P < .001) compared to index echocardiography, and predicted by higher initial Zva (optimized cutoff >4.77 mm Hg/mL/m 2 , AUC = 0.81 [95% CI:0.75-0.87, P < .001]). In patients with low flow, 25% switched to normal flow, which was associated with lower Zva and higher SAC and the switch was predicted by a higher initial mean transaortic pressure gradient. A significant number of patients switched flow categories in severe AS with preserved LVEF on subsequent echocardiography. Changes in flow were reflected by respective changes in Zva and SAC. Identifying echocardiographic predictors of a switch in category may guide prognostication and management of such patients. © 2017, Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rabinovitch, M.A.; Rose, C.P.; Rouleau, J.L.
1987-12-01
In heart failure secondary to chronic mechanical overload, cardiac sympathetic neurons demonstrate depressed catecholamine synthetic and transport function. To assess the potential of sympathetic neuronal imaging for detection of depressed transport function, serial scintigrams were acquired after the intravenous administration of metaiodobenzylguanidine (/sup 131/I) to 13 normal dogs, 3 autotransplanted (denervated) dogs, 5 dogs with left ventricular failure, and 5 dogs with compensated left ventricular hypertrophy due to a surgical arteriovenous shunt. Nine dogs were killed at 14 hours postinjection for determination of metaiodobenzylguanidine (/sup 131/I) and endogenous norepinephrine content in left atrium, left ventricle, liver, and spleen. By 4more » hours postinjection, autotransplanted dogs had a 39% reduction in mean left ventricular tracer accumulation, reflecting an absent intraneuronal tracer pool. Failure dogs demonstrated an accelerated early mean left ventricular tracer efflux rate (26.0%/hour versus 13.7%/hour in normals), reflecting a disproportionately increased extraneuronal tracer pool. They also showed reduced late left ventricular and left atrial concentrations of tracer, consistent with a reduced intraneuronal tracer pool. By contrast, compensated hypertrophy dogs demonstrated a normal early mean left ventricular tracer efflux rate (16.4%/hour) and essentially normal late left ventricular and left atrial concentrations of tracer. Metaiodobenzylguanidine (/sup 131/I) scintigraphic findings reflect the integrity of the cardiac sympathetic neuronal transport system in canine mechanical-overload heart failure. Metaiodobenzylguanidine (/sup 123/I) scintigraphy should be explored as a means of early detection of mechanical-overload heart failure in patients.« less
Garcia, M J; Firstenberg, M S; Greenberg, N L; Smedira, N; Rodriguez, L; Prior, D; Thomas, J D
2001-02-01
Shortened early transmitral deceleration times (E(DT)) have been qualitatively associated with increased filling pressure and reduced survival in patients with cardiac disease and increased left ventricular operating stiffness (K(LV)). An equation relating K(LV) quantitatively to E(DT) has previously been described in a canine model but not in humans. During several varying hemodynamic conditions, we studied 18 patients undergoing open-heart surgery. Transesophageal echocardiographic two-dimensional volumes and Doppler flows were combined with high-fidelity left atrial (LA) and left ventricular (LV) pressures to determine K(LV). From digitized Doppler recordings, E(DT) was measured and compared against changes in LV and LA diastolic volumes and pressures. E(DT) (180 +/- 39 ms) was inversely associated with LV end-diastolic pressures (r = -0.56, P = 0.004) and net atrioventricular stiffness (r = -0.55, P = 0.006) but had its strongest association with K(LV) (r = -0.81, P < 0.001). K(LV) was predicted assuming a nonrestrictive orifice (K(nonrest)) from E(DT) as K(nonrest) = (0.07/E(DT))(2) with K(LV) = 1.01 K(nonrest) - 0.02; r = 0.86, P < 0.001, DeltaK (K(nonrest) - K(LV)) = 0.02 +/- 0.06 mm Hg/ml. In adults with cardiac disease, E(DT) provides an accurate estimate of LV operating stiffness and supports its application as a practical noninvasive index in the evaluation of diastolic function.
NASA Technical Reports Server (NTRS)
Garcia, M. J.; Firstenberg, M. S.; Greenberg, N. L.; Smedira, N.; Rodriguez, L.; Prior, D.; Thomas, J. D.
2001-01-01
Shortened early transmitral deceleration times (E(DT)) have been qualitatively associated with increased filling pressure and reduced survival in patients with cardiac disease and increased left ventricular operating stiffness (K(LV)). An equation relating K(LV) quantitatively to E(DT) has previously been described in a canine model but not in humans. During several varying hemodynamic conditions, we studied 18 patients undergoing open-heart surgery. Transesophageal echocardiographic two-dimensional volumes and Doppler flows were combined with high-fidelity left atrial (LA) and left ventricular (LV) pressures to determine K(LV). From digitized Doppler recordings, E(DT) was measured and compared against changes in LV and LA diastolic volumes and pressures. E(DT) (180 +/- 39 ms) was inversely associated with LV end-diastolic pressures (r = -0.56, P = 0.004) and net atrioventricular stiffness (r = -0.55, P = 0.006) but had its strongest association with K(LV) (r = -0.81, P < 0.001). K(LV) was predicted assuming a nonrestrictive orifice (K(nonrest)) from E(DT) as K(nonrest) = (0.07/E(DT))(2) with K(LV) = 1.01 K(nonrest) - 0.02; r = 0.86, P < 0.001, DeltaK (K(nonrest) - K(LV)) = 0.02 +/- 0.06 mm Hg/ml. In adults with cardiac disease, E(DT) provides an accurate estimate of LV operating stiffness and supports its application as a practical noninvasive index in the evaluation of diastolic function.
Demirçelik, Muhammed Bora; Çetin, Mustafa; Çiçekcioğlu, Hülya; Uçar, Özgül; Duran, Mustafa
2014-05-01
We aimed to investigate effects of left ventricular diastolic dysfunction on left atrial appendage functions, spontaneous echo contrast and thrombus formation in patients with nonvalvular atrial fibrillation. In 58 patients with chronic nonvalvular atrial fibrilation and preserved left ventricular systolic function, left atrial appendage functions, left atrial spontaneous echo contrast grading and left ventricular diastolic functions were evaluated using transthoracic and transoesophageal echocardiogram. Patients divided in two groups: Group D (n=30): Patients with diastolic dysfunction, Group N (n=28): Patients without diastolic dysfunction. Categorical variables in two groups were evaluated with Pearson's chi-square or Fisher's exact test. The significance of the lineer correlation between the degree of spontaneous echo contrast (SEC) and clinical measurements was evaluated with Spearman's correlation analysis. Peak pulmonary vein D velocity of the Group D was significantly higher than the Group N (p=0.006). However, left atrial appendage emptying velocity, left atrial appendage lateral wall velocity, peak pulmonary vein S, pulmonary vein S/D ratio were found to be significantly lower in Group D (p=0.028, p<0.001, p<0.001; p<0.001). Statistically significant negative correlation was found between SEC in left atrium and left atrial appendage emptying, filling, pulmonary vein S/D levels and lateral wall velocities respectively (r=-0.438, r=-0.328, r=-0.233, r=-0.447). Left atrial appendage emptying, filling, pulmonary vein S/D levels and lateral wall velocities were significantly lower in SEC 2-3-4 than SEC 1 (p=0.003, p=0.029, p<0.001, p=0.002). In patients with nonvalvular atrial fibrillation and preserved left ventricular ejection fraction, left atrial appendage functions are decreased in patients with left ventricular diastolic dysfunction. Left ventricular diastolic dysfunction may constitute a potential risk for formation of thrombus and stroke.
Hochwald, Ori; Jabr, Mohammad; Osiovich, Horacio; Miller, Steven P; McNamara, Patrick J; Lavoie, Pascal M
2014-05-01
To determine the relationship between left ventricular cardiac output (LVCO), superior vena cava (SVC) flow, and brain injury during whole-body therapeutic hypothermia. Sixteen newborns with moderate or severe hypoxic-ischemic encephalopathy were studied using echocardiography during and immediately after therapeutic hypothermia. Measures were also compared with 12 healthy newborns of similar postnatal age. Newborns undergoing therapeutic hypothermia also had cerebral magnetic resonance imaging as part of routine clinical care on postnatal day 3-4. LVCO was markedly reduced (mean ± SD 126 ± 38 mL/kg/min) during therapeutic hypothermia, whereas SVC flow was maintained within expected normal values (88 ± 27 mL/kg/min) such that SVC flow represented 70% of the LVCO. The reduction in LVCO during therapeutic hypothermia was mainly accounted by a reduction in heart rate (99 ± 13 vs 123 ± 17 beats/min; P < .001) compared with immediately postwarming in the context of myocardial dysfunction. Neonates with brain injury on magnetic resonance imaging had higher SVC flow prerewarming, compared with newborns without brain injury (P = .013). Newborns with perinatal hypoxic-ischemic encephalopathy showed a preferential systemic-to-cerebral redistribution of cardiac blood flow during whole-body therapeutic hypothermia, which may reflect a lack of cerebral vascular adaptation in newborns with more severe brain injury. Copyright © 2014 Elsevier Inc. All rights reserved.
Kimura, Sumito; Streiff, Cole; Zhu, Meihua; Shimada, Eriko; Datta, Saurabh; Ashraf, Muhammad; Sahn, David J
2014-02-01
The aim of this study was to assess the accuracy, feasibility, and reproducibility of determining stroke volume from a novel 3-dimensional (3D) color Doppler flow quantification method for mitral valve (MV) inflow and left ventricular outflow tract (LVOT) outflow at different stroke volumes when compared with the actual flow rate in a pumped porcine cardiac model. Thirteen freshly harvested pig hearts were studied in a water tank. We inserted a latex balloon into each left ventricle from the MV annulus to the LVOT, which were passively pumped at different stroke volumes (30-80 mL) using a calibrated piston pump at increments of 10 mL. Four-dimensional flow volumes were obtained without electrocardiographic gating. The digital imaging data were analyzed offline using prototype software. Two hemispheric flow-sampling planes for color Doppler velocity measurements were placed at the MV annulus and LVOT. The software computed the flow volumes at the MV annulus and LVOT within the user-defined volume and cardiac cycle. This novel 3D Doppler flow quantification method detected incremental increases in MV inflow and LVOT outflow in close agreement with pumped stroke volumes (MV inflow, r = 0.96; LVOT outflow, r = 0.96; P < .01). Bland-Altman analysis demonstrated overestimation of both (MV inflow, 5.42 mL; LVOT outflow, 4.46 mL) with 95% of points within 95% limits of agreement. Interobserver variability values showed good agreement for all stroke volumes at both the MV annulus and LVOT. This study has shown that the 3D color Doppler flow quantification method we used is able to compute stroke volumes accurately at the MV annulus and LVOT in the same cardiac cycle without electrocardiographic gating. This method may be valuable for assessment of cardiac output in clinical studies.
Fernández, Angel L; García-Bengochea, José B; Ledo, Ramiro; Vega, Marino; Amaro, Antonio; Alvarez, Julián; Rubio, José; Sierra, Juan; Sánchez, Daniel
2004-04-01
Cardiac resynchronization via left ventricular or biventricular pacing is an option for selected patients with ventricular systolic dysfunction and widened QRS complex. Stimulation through a coronary vein is the technique of choice for left ventricular pacing, but this approach results in a failure rate of approximately 8%. We describe our initial experience with minimally invasive surgical implantation of left ventricular epicardial leads using video-assisted thoracoscopy. A total of 14 patients with congestive heart failure, NYHA functional class 3.2 (0.6) and mean ejection fraction 22.9 (6.8)% were included in this study. Left bundle branch block, QRS complex >140 ms and abnormal septal motion were observed in all cases. Epicardial leads were implanted on the left ventricular free wall under general anesthesia using video-assisted thoracoscopic surgery. Lead implantation was successful in 13 patients. Conversion to a small thoracotomy was necessary in one patient. All patients were extubated in the operating room. None of the patients died during their hospital stay. Follow-up showed reversal of ventricular asynchrony and significant improvement in ejection fraction and functional class. Minimally invasive surgery for ventricular resynchronization using video-assisted thoracoscopy in selected patients is a safe procedure that makes it possible to choose the best site for lead implantation and provides adequate short- and medium-term stimulation.
Chopski, Steven G; Murad, Nohra M; Fox, Carson S; Stevens, Randy M; Throckmorton, Amy L
2018-05-10
The clinical implementation of mechanical circulatory assistance for a significantly dysfunctional or failing left ventricle as a bridge-to-transplant or bridge-to-recovery is on the rise. Thousands of patients with left-sided heart failure are readily benefitting from these life-saving technologies, and left ventricular failure often leads to severe right ventricular dysfunction or failure. Right ventricular failure (RVF) has a high rate of mortality caused by the risk of multisystem organ failure and prolonged hospitalization for patients after treatment. The use of a blood pump to support the left ventricle also typically results in an increase in right ventricular preload and may impair right ventricular contractility during left ventricular unloading. Patients with RVF might also suffer from severe pulmonary dysfunction, cardiac defects, congenital heart disease states, or a heterogeneity of cardiophysiologic challenges because of symptomatic congestive heart failure. Thus, the uniqueness and complexity of RVF is emerging as a new domain of significant clinical interest that motivates the development of right ventricular assist devices. In this review, we present the current state-of-the-art for clinically used blood pumps to support adults and pediatric patients with right ventricular dysfunction or failure concomitant with left ventricular failure. New innovative devices specifically for RVF are also highlighted. There continues to be a compelling need for novel treatment options to support patients with significant right heart dysfunction or failure.
Ethical challenges with the left ventricular assist device as a destination therapy
Rizzieri, Aaron G; Verheijde, Joseph L; Rady, Mohamed Y; McGregor, Joan L
2008-01-01
The left ventricular assist device was originally designed to be surgically implanted as a bridge to transplantation for patients with chronic end-stage heart failure. On the basis of the REMATCH trial, the US Food and Drug Administration and the US Centers for Medicare & Medicaid Services approved permanent implantation of the left ventricular assist device as a destination therapy in Medicare beneficiaries who are not candidates for heart transplantation. The use of the left ventricular assist device as a destination therapy raises certain ethical challenges. Left ventricular assist devices can prolong the survival of average recipients compared with optimal medical management of chronic end-stage heart failure. However, the overall quality of life can be adversely affected in some recipients because of serious infections, neurologic complications, and device malfunction. Left ventricular assist devices alter end-of-life trajectories. The caregivers of recipients may experience significant burden (e.g., poor physical health, depression, anxiety, and posttraumatic stress disorder) from destination therapy with left ventricular assist devices. There are also social and financial ramifications for recipients and their families. We advocate early utilization of a palliative care approach and outline prerequisite conditions so that consenting for the use of a left ventricular assist device as a destination therapy is a well informed process. These conditions include: (1) direct participation of a multidisciplinary care team, including palliative care specialists, (2) a concise plan of care for anticipated device-related complications, (3) careful surveillance and counseling for caregiver burden, (4) advance-care planning for anticipated end-of-life trajectories and timing of device deactivation, and (5) a plan to address the long-term financial burden on patients, families, and caregivers. Short-term mechanical circulatory devices (e.g. percutaneous cardiopulmonary bypass, percutaneous ventricular assist devices, etc.) can be initiated in emergency situations as a bridge to permanent implantation of ventricular assist devices in chronic end-stage heart failure. In the absence of first-person (patient) consent, presumed consent or surrogate consent should be used cautiously for the initiation of short-term mechanical circulatory devices in emergency situations as a bridge to permanent implantation of left ventricular assist devices. Future clinical studies of destination therapy with left ventricular assist devices should include measures of recipients' quality of end-of-life care and caregivers' burden. PMID:18694496
Ikeda, Hiroyuki; Uzui, Hiroyasu; Morishita, Tetsuji; Fukuoka, Yoshitomo; Sato, Takehiko; Ishida, Kentaro; Kaseno, Kenichi; Arakawa, Kenichiro; Amaya, Naoki; Tama, Naoto; Shiomi, Yuichiro; Lee, Jong-Dae; Tada, Hiroshi
2015-11-01
This study investigated whether postprandial hyperglycaemia has an adverse effect on coronary microvascular function and left ventricular diastolic function. In all, 28 patients with type 2 diabetes mellitus with no significant stenosis in left anterior descending artery were enrolled. In all subjects, plasma 1,5-anhydroglucitol was measured, and coronary flow reserve in the left anterior descending artery was evaluated using a Doppler wire. Membrane type-1 matrix metalloproteinase expression on circulating peripheral blood mononuclear cells was measured by flow cytometry. Correlation analyses were performed for coronary flow reserve and 1,5-anhydroglucitol, other coronary risk factors, membrane type-1 matrix metalloproteinase and E/e'. Strong correlations were found only between 1,5-anhydroglucitol and coronary flow reserve and membrane type-1 matrix metalloproteinase. On multiple regression analysis, 1,5-anhydroglucitol remained an independent predictor of coronary flow reserve (β = 0.38, p = 0.048). Postprandial hyperglycaemia appears to have an adverse effect on coronary microvascular function, suggesting that improvement of postprandial hyperglycaemia may contribute to the improvement of coronary microvascular dysfunction. © The Author(s) 2015.
ERIC Educational Resources Information Center
Crowley, Julianne; Titmus, Morgan
2016-01-01
This article explores an alternative conception held by high school and first-year university biology students regarding the structure of the left and right ventricles of the heart and the significance of the left ventricular wall being thicker than the right. The left ventricular wall of the heart is thicker than the right ventricular wall due to…
Recurrent Takotsubo Cardiomyopathy Related to Recurrent Thyrotoxicosis.
Patel, Keval; Griffing, George T; Hauptman, Paul J; Stolker, Joshua M
2016-04-01
Takotsubo cardiomyopathy, or transient left ventricular apical ballooning syndrome, is characterized by acute left ventricular dysfunction caused by transient wall-motion abnormalities of the left ventricular apex and mid ventricle in the absence of obstructive coronary artery disease. Recurrent episodes are rare but have been reported, and several cases of takotsubo cardiomyopathy have been described in the presence of hyperthyroidism. We report the case of a 55-year-old woman who had recurrent takotsubo cardiomyopathy, documented by repeat coronary angiography and evaluations of left ventricular function, in the presence of recurrent hyperthyroidism related to Graves disease. After both episodes, the patient's left ventricular function returned to normal when her thyroid function normalized. These findings suggest a possible role of thyroid-hormone excess in the pathophysiology of some patients who have takotsubo cardiomyopathy.
Diastolic dysfunction in hypertension.
Nazário Leão, R; Marques da Silva, P
Hypertension and coronary heart disease, often coexisting, are the most common risk factors for heart failure. The progression of hypertensive heart disease involves myocardial fibrosis and alterations in the left ventricular geometry that precede the functional change, initially asymptomatic. The left ventricular diastolic dysfunction is part of this continuum being defined by the presence of left ventricular diastolic dysfunction without signs or symptoms of heart failure or poor left ventricular systolic function. It is highly prevalent in hypertensive patients and is associated with increased cardiovascular morbidity and mortality. Despite its growing importance in clinical practice it remains poorly understood. This review aims to present the epidemiological fundamentals and the latest developments in the pathophysiology, diagnosis and treatment of left ventricular diastolic dysfunction. Copyright © 2017 SEH-LELHA. Publicado por Elsevier España, S.L.U. All rights reserved.
Liu, Dan; Hu, Kai; Nordbeck, Peter; Ertl, Georg; Störk, Stefan; Weidemann, Frank
2016-05-10
Despite substantial advances in the imaging techniques and pathophysiological understanding over the last decades, identification of the underlying causes of left ventricular hypertrophy by means of echocardiographic examination remains a challenge in current clinical practice. The longitudinal strain bull's eye plot derived from 2D speckle tracking imaging offers an intuitive visual overview of the global and regional left ventricular myocardial function in a single diagram. The bull's eye mapping is clinically feasible and the plot patterns could provide clues to the etiology of cardiomyopathies. The present review summarizes the longitudinal strain, bull's eye plot features in patients with various cardiomyopathies and concentric left ventricular hypertrophy and the bull's eye plot features might serve as one of the cardiac workup steps on evaluating patients with left ventricular hypertrophy.
Saline-Induced Coronary Hyperemia: Mechanisms and Effects on Left Ventricular Function.
De Bruyne, Bernard; Adjedj, Julien; Xaplanteris, Panagiotis; Ferrara, Angela; Mo, Yujing; Penicka, Martin; Floré, Vincent; Pellicano, Mariano; Toth, Gabor; Barbato, Emanuele; Duncker, Dirk J; Pijls, Nico H J
2017-04-01
During thermodilution-based assessment of volumetric coronary blood flow, we observed that intracoronary infusion of saline increased coronary flow. This study aims to quantify the extent and unravel the mechanisms of saline-induced hyperemia. Thirty-three patients were studied; in 24 patients, intracoronary Doppler flow velocity measurements were performed at rest, after intracoronary adenosine, and during increasing infusion rates of saline at room temperature through a dedicated catheter with 4 lateral side holes. In 9 patients, global longitudinal strain and flow propagation velocity were assessed by transthoracic echocardiography during a prolonged intracoronary saline infusion. Taking adenosine-induced maximal hyperemia as reference, intracoronary infusion of saline at rates of 5, 10, 15, and 20 mL/min induced 6%, 46%, 111%, and 112% of maximal hyperemia, respectively. There was a close agreement of maximal saline- and adenosine-induced coronary flow reserve (intraclass correlation coefficient, 0.922; P <0.001). The same infusion rates given through 1 end hole (n=6) or in the contralateral artery (n=6) did not induce a significant increase in flow velocity. Intracoronary saline given on top of an intravenous infusion of adenosine did not further increase flow. Intracoronary saline infusion did not affect blood pressure, systolic, or diastolic left ventricular function. Heart rate decreased by 15% during saline infusion ( P =0.021). Intracoronary infusion of saline at room temperature through a dedicated catheter for coronary thermodilution induces steady-state maximal hyperemia at a flow rate ≥15 mL/min. These findings open new possibilities to measure maximal absolute coronary blood flow and minimal microcirculatory resistance. © 2017 American Heart Association, Inc.
Seebaluck, Sh; Babaev, M V; Kondrashev, A V
2003-01-01
The objective of this study was to analyze echocardiographic parameters in 143 healthy individuals aged 18-21 years with different somatotypes. The evaluation of somatotype was performed using the the method of R.N. Dorokhov and V.G. Petrukhin (1989). During the echocardiography, left ventricular wall thickness, internal diameter and myocardial mass were measured. The investigation showed marked sex- and somatotype-related differences in left ventricular parameters. The correlations between the studied left ventricular parameters and body mass, length and surface area were demonstrated. The optimal method of the indexation of left ventricular myocardial mass as related to (body length)3, is described.
Combellas, I; Puigbo, J J; Acquatella, H; Tortoledo, F; Gomez, J R
1985-01-01
To study left ventricular diastolic function in Chagas's disease, simultaneous echocardiograms, phonocardiograms, and apexcardiograms were recorded in 20 asymptomatic patients with positive Chagas's serology and no signs of heart disease (group 1), 12 with Chagas's heart disease and symptoms of ventricular arrhythmia but no heart failure (group 2), 20 normal subjects (group 3), and 12 patients with left ventricular hypertrophy (group 4). The recordings were digitised to determine left ventricular isovolumic relaxation time and the rate and duration of left ventricular cavity dimension increase and wall thinning. In groups 1 and 2 (a) aortic valve closure (A2) and mitral valve opening were significantly delayed relative to minimum dimension and were associated with prolonged isovolumic relaxation, (b) left ventricular cavity size was abnormally increased during isovolumic relaxation and abnormally reduced during isovolumic contraction, and (c) peak rate of posterior wall thinning and dimension increase were significantly reduced and duration of posterior wall thinning was significantly prolonged; both of these abnormalities occurred at the onset of diastolic filling. These abnormalities were more pronounced in group 2 and were accompanied by an increase in the height of the apexcardiogram "a" wave, an indication of pronounced atrial systole secondary to end diastolic filling impairment due to reduced left ventricular distensibility. Group 4, which had an established pattern of diastolic abnormalities, showed changes similar to those in group 2; however, the delay in aortic valve closure (A2) and in mitral valve opening and the degree of dimension change were greater in the latter group. Thus early isovolumic relaxation and left ventricular abnormalities were pronounced in the patients with Chagas's heart disease and may precede systolic compromise, which may become apparent in later stages of the disease. The digitised method is valuable in the early detection of myocardial damage. Images PMID:3155954
NASA Technical Reports Server (NTRS)
Nakatani, S.; Thomas, J. D.; Vandervoort, P. M.; Zhou, J.; Greenberg, N. L.; Savage, R. M.; McCarthy, P. M.
1997-01-01
OBJECTIVES: We studied the effects of left ventricular (LV) unloading by an implantable ventricular assist device on LV diastolic filling. BACKGROUND: Although many investigators have reported reliable systemic and peripheral circulatory support with implantable LV assist devices, little is known about their effect on cardiac performance. METHODS: Peak velocities of early diastolic filling, late diastolic filling, late to early filling ratio, deceleration time of early filling, diastolic filling period and atrial filling fraction were measured by intraoperative transesophageal Doppler echocardiography before and after insertion of an LV assist device in eight patients. A numerical model was developed to simulate this situation. RESULTS: Before device insertion, all patients showed either a restrictive or a monophasic transmitral flow pattern. After device insertion, transmitral flow showed rapid beat to beat variation in each patient, from abnormal relaxation to restrictive patterns. However, when the average values obtained from 10 consecutive beats were considered, overall filling was significantly normalized from baseline, with early filling velocity falling from 87 +/- 31 to 64 +/- 26 cm/s (p < 0.01) and late filling velocity rising from 8 +/- 11 to 32 +/- 23 cm/s (p < 0.05), resulting in an increase in the late to early filling ratio from 0.13 +/- 0.18 to 0.59 +/- 0.38 (p < 0.01) and a rise in the atrial filling fraction from 8 +/- 10% to 26 +/- 17% (p < 0.01). The deceleration time (from 112 +/- 40 to 160 +/- 44 ms, p < 0.05) and the filling period corrected by the RR interval (from 39 +/- 8% to 54 +/- 10%, p < 0.005) were also significantly prolonged. In the computer model, asynchronous LV assistance produced significant beat to beat variation in filling indexes, but overall a normalization of deceleration time as well as other variables. CONCLUSIONS: With LV assistance, transmitral flow showed rapidly varying patterns beat by beat in each patient, but overall diastolic filling tended to normalize with an increase of atrial contribution to the filling. Because of the variable nature of the transmitral flow pattern with the assist device, the timing of the device cycle must be considered when inferring diastolic function from transmitral flow pattern.
Srimachai, Sirintorn; Devaux, Sylvie; Demougeot, Celine; Kumphune, Sarawut; Ullrich, Nina D; Niggli, Ernst; Ingkaninan, Kornkanok; Kamkaew, Natakorn; Scholfield, C Norman; Tapechum, Sompol; Chootip, Krongkarn
2017-02-20
This study explored Bacopa monnieri, a medicinal Ayurvedic herb, as a cardioprotectant against ischemia/reperfusion injury using cardiac function and coronary flow as end-points. In normal isolated rat hearts, coronary flow, left ventricular developed pressure, heart rate, and functional recovery were measured using the Langendorff preparation. Hearts were perfused with either (i) Krebs-Henseleit (normal) solution, (control), or with 30, 100 μg/ml B. monnieri ethanolic extract (30 min), or (ii) with normal solution or extract for 10 min preceding no-perfusion ischemia (30 min) followed by reperfusion (30 min) with normal solution. Infarct volumes were measured by triphenyltetrazolium staining. L-type Ca 2+ -currents (I Ca, L ) were measured by whole-cell patching in HL-1 cells, a mouse atrial cardiomyocyte cell line. Cytotoxicity of B. monnieri was assessed in rat isolated ventricular myocytes by trypan blue exclusion. In normally perfused hearts, B. monnieri increased coronary flow by 63 ± 13% (30 μg/ml) and 216 ± 21% (100 μg/ml), compared to control (5 ± 3%) (n = 8-10, p < 0.001). B. monnieri treatment preceding ischemia/reperfusion improved left ventricular developed pressure by 84 ± 10% (30 μg/ml), 82 ± 10% (100 μg/ml) and 52 ± 6% (control) compared to pre- ischemia/reperfusion. Similarly, functional recovery showed a sustained increase. Moreover, B. monnieri (100 μg/ml) reduced the percentage of infarct size from 51 ± 2% (control) to 25 ± 2% (n = 6-8, p < 0.0001). B. monnieri (100 μg/ml) reduced I Ca, L by 63 ± 4% in HL-1 cells. Ventricular myocyte survival decreased at higher concentrations (50-1000 μg/ml) B. monnieri. B. monnieri improves myocardial function following ischemia/reperfusion injury through recovery of coronary blood flow, contractile force and decrease in infarct size. Thus this may lead to a novel cardioprotectant strategy.
Left ventricular dysfunction after closure of large patent ductus arteriosus.
Galal, M Omar; Amin, Mohamed; Hussein, Arif; Kouatli, Amjad; Al-Ata, Jameel; Jamjoom, Ahmed
2005-03-01
Changes in left ventricular dimensions and performance were studied in 43 patients after transcatheter occlusion or surgical ligation of patent ductus arteriosus. The patients were assigned to 2 groups based on their ductal diameter: >/= 3.1 mm to group A (n = 27) and = 3 mm to group B (n = 16). The mean age and weight of the groups were comparable. Before intervention, group A had a significantly larger mean left ventricular end-diastolic diameter than group B, while all patients had normal shortening fraction and ejection fraction. Within 1 month after intervention, left ventricular end-diastolic diameter showed a trend towards regression while shortening fraction and ejection fraction decreased significantly in group A. There were no significant changes in these parameters in group B. Between 1 and 6 months after intervention, left ventricular performance improved in most of the group A patients who were followed up. We conclude that closure of large ductus arteriosus in children leads to significant immediate deterioration of left ventricular performance, which appears to recover within a few months. Echocardiographic study before hospital discharge is recommended in these patients. Serious deterioration of ventricular performance after closure may warrant the use of angiotensin converting enzyme inhibitors.
Mitral regurgitation: anatomy is destiny.
Athanasuleas, Constantine L; Stanley, Alfred W H; Buckberg, Gerald D
2018-04-26
Mitral regurgitation (MR) occurs when any of the valve and ventricular mitral apparatus components are disturbed. As MR progresses, left ventricular remodelling occurs, ultimately causing heart failure when the enlarging left ventricle (LV) loses its conical shape and becomes globular. Heart failure and lethal ventricular arrhythmias may develop if the left ventricular end-systolic volume index exceeds 55 ml/m2. These adverse changes persist despite satisfactory correction of the annular component of MR. Our goal was to describe this process and summarize evolving interventions that reduce the volume of the left ventricle and rebuild its elliptical shape. This 'valve/ventricle' approach addresses the spherical ventricular culprit and offsets the limits of treating MR by correcting only its annular component.
Bohm, Philipp; Schneider, Günther; Linneweber, Lutz; Rentzsch, Axel; Krämer, Nadine; Abdul-Khaliq, Hashim; Kindermann, Wilfried; Meyer, Tim; Scharhag, Jürgen
2016-05-17
It is under debate whether the cumulative effects of intensive endurance exercise induce chronic cardiac damage, mainly involving the right heart. The aim of this study was to examine the cardiac structure and function in long-term elite master endurance athletes with special focus on the right ventricle by contrast-enhanced cardiovascular magnetic resonance. Thirty-three healthy white competitive elite male master endurance athletes (age range, 30-60 years) with a training history of 29±8 years, and 33 white control subjects pair-matched for age, height, and weight underwent cardiopulmonary exercise testing, echocardiography including tissue-Doppler imaging and speckle tracking, and cardiovascular magnetic resonance. Indexed left ventricular mass and right ventricular mass (left ventricular mass/body surface area, 96±13 and 62±10 g/m(2); P<0.001; right ventricular mass/body surface area, 36±7 and 24±5 g/m(2); P<0.001) and indexed left ventricular end-diastolic volume and right ventricular end-diastolic volume (left ventricular end-diastolic volume/body surface area, 104±13 and 69±18 mL/m(2); P<0.001; right ventricular end-diastolic volume/body surface area, 110±22 and 66±16 mL/m(2); P<0.001) were significantly increased in athletes in comparison with control subjects. Right ventricular ejection fraction did not differ between athletes and control subjects (52±8 and 54±6%; P=0.26). Pathological late enhancement was detected in 1 athlete. No correlations were found for left ventricular and right ventricular volumes and ejection fraction with N-terminal pro-brain natriuretic peptide, and high-sensitive troponin was negative in all subjects. Based on our results, chronic right ventricular damage in elite endurance master athletes with lifelong high training volumes seems to be unlikely. Thus, the hypothesis of an exercise-induced arrhythmogenic right ventricular cardiomyopathy has to be questioned. © 2016 American Heart Association, Inc.
Compostella, Leonida; Russo, Nicola; Setzu, Tiziana; Bottio, Tomaso; Compostella, Caterina; Tarzia, Vincenzo; Livi, Ugolino; Gerosa, Gino; Iliceto, Sabino; Bellotto, Fabio
2015-01-01
An increasing number of patients with end-stage heart failure are being treated with continuous-flow left ventricular assist devices (cf-LVADs). These patients provide new challenges to the staff in exercise-based cardiac rehabilitation (CR) programs. Even though experience remains limited, it seems that patients supported by cf-LVADs may safely engage in typical rehabilitative activities, provided that some attention is paid to specific aspects, such as the presence of a short external drive line. In spite of initial physical deconditioning, CR allows progressive improvement of symptoms such as fatigue and dyspnea. Intensity of rehabilitative activities should ideally be based on measured aerobic capacity and increased appropriately over time. Regular, long-term exercise training results in improved physical fitness and survival rates. Appropriate adjustment of cf-LVAD settings, together with maintenance of adequate blood volume, provides maximal output, while avoiding suction effects. Ventricular arrhythmias, although not necessarily constituting an immediate life-threatening situation, deserve treatment as they could lead to an increased rate of hospitalization and poorer quality of life. Atrial fibrillation may worsen symptoms of right ventricular failure and reduce exercise tolerance. Blood pressure measurements are possible in cf-LVAD patients only using a Doppler technique, and a mean blood pressure ≤80 mmHg is considered "ideal." Some patients may present with orthostatic intolerance, related to autonomic dysfunction. While exercise training constitutes the basic rehabilitative tool, a comprehensive intervention that includes psychological and social support could better meet the complex needs of patients in which cf-LVAD may offer prolonged survival.
Left ventricular pressure and volume data acquisition and analysis using LabVIEW.
Cassidy, S C; Teitel, D F
1997-03-01
To automate analysis of left ventricular pressure-volume data, we used LabVIEW to create applications that digitize and display data recorded from conductance and manometric catheters. Applications separate data into cardiac cycles, calculate parallel conductance, and calculate indices of left ventricular function, including end-systolic elastance, preload-recruitable stroke work, stroke volume, ejection fraction, stroke work, maximum and minimum derivative of ventricular pressure, heart rate, indices of relaxation, peak filling rate, and ventricular chamber stiffness. Pressure-volume loops can be graphically displayed. These analyses are exported to a text-file. These applications have simplified and automated the process of evaluating ventricular function.
Eroglu, Serpil; Sade, Elif; Bozbas, Huseyin; Pirat, Bahar; Yildirir, Aylin; Muderrisoglu, Haldun
2008-03-01
Left ventricular-right atrial communication, known as a Gerbode-type defect, is a rare form of ventricular septal defect. It is usually congenital, but rarely acquired. Clinical presentation is associated with the volume of the shunt. Transthoracic echocardiography is the most useful diagnostic method. We present a 63-year-old man with chronic renal failure and left ventricular-right atrial shunt.
NASA Astrophysics Data System (ADS)
Jang, Jaeseong; Ahn, Chi Young; Jeon, Kiwan; Choi, Jung-il; Lee, Changhoon; Seo, Jin Keun
2015-03-01
A reconstruction method is proposed here to quantify the distribution of blood flow velocity fields inside the left ventricle from color Doppler echocardiography measurement. From 3D incompressible Navier- Stokes equation, a 2D incompressible Navier-Stokes equation with a mass source term is derived to utilize the measurable color flow ultrasound data in a plane along with the moving boundary condition. The proposed model reflects out-of-plane blood flows on the imaging plane through the mass source term. For demonstrating a feasibility of the proposed method, we have performed numerical simulations of the forward problem and numerical analysis of the reconstruction method. First, we construct a 3D moving LV region having a specific stroke volume. To obtain synthetic intra-ventricular flows, we performed a numerical simulation of the forward problem of Navier-Stokes equation inside the 3D moving LV, computed 3D intra-ventricular velocity fields as a solution of the forward problem, projected the 3D velocity fields on the imaging plane and took the inner product of the 2D velocity fields on the imaging plane and scanline directional velocity fields for synthetic scanline directional projected velocity at each position. The proposed method utilized the 2D synthetic projected velocity data for reconstructing LV blood flow. By computing the difference between synthetic flow and reconstructed flow fields, we obtained the averaged point-wise errors of 0.06 m/s and 0.02 m/s for u- and v-components, respectively.
Ye, Min; Tian, Na; Liu, Yanqiu; Li, Wei; Lin, Hong; Fan, Rui; Li, Cuiling; Liu, Donghong; Yao, Fengjuan
We initiated this study to explore the relationships of serum phosphorus level with left ventricular ultrasound features and diastolic function in peritoneal dialysis (PD) patients. 174 patients with end-stage renal disease (ESRD) receiving PD were enrolled in this retrospective observational study. Conventional echocardiography examination and tissue Doppler imaging (TDI) were performed in each patient. Clinical information and laboratory data were also collected. Analyses of echocardiographic features were performed according to phosphorus quartiles groups. And multivariate regression models were used to determine the association between serum phosphorus and Left ventricular diastolic dysfunction (LVDD). With the increase of serum phosphorus levels, patients on PD showed an increased tissue Doppler-derived E/e' ratio of lateral wall (P < 0.001), indicating a deterioration of left ventricular diastolic function. Steady growths of left atrium and left ventricular diameters as well as increase of left ventricular muscle mass were also observed across the increasing quartiles of phosphorus, while left ventricular ejection fraction remained normal. In a multivariate analysis, the regression coefficient for E/e' ratio in the highest phosphorus quartile was almost threefold higher relative to those in the lowest quartile group. And compared with patients in the lowest phosphorus quartile (<1.34 mmol/L) those in the highest phosphorus quartile (>1.95 mmol/L) had a more than fivefold increased odds of E/e' ratio >15. Our study showed an early impairment of left ventricular diastolic function in peritoneal dialysis patients. High serum phosphorus level was independently associated with greater risk of LVDD in these patients. Whether serum phosphorus will be a useful target for prevention or improvement of LVDD remains to be proved by further studies.
Silva, Etelvino; Bijnens, Bart; Berruezo, Antonio; Mont, Lluis; Doltra, Adelina; Andreu, David; Brugada, Josep; Sitges, Marta
2014-10-01
There is extensive controversy exists on whether cardiac resynchronization therapy corrects electrical or mechanical asynchrony. The aim of this study was to determine if there is a correlation between electrical and mechanical sequences and if myocardial scar has any relevant impact. Six patients with normal left ventricular function and 12 patients with left ventricular dysfunction and left bundle branch block, treated with cardiac resynchronization therapy, were studied. Real-time three-dimensional echocardiography and electroanatomical mapping were performed in all patients and, where applicable, before and after therapy. Magnetic resonance was performed for evaluation of myocardial scar. Images were postprocessed and mechanical and electrical activation sequences were defined and time differences between the first and last ventricular segment to be activated were determined. Response to therapy was defined as a reduction in left ventricular end-systolic volume ≥ 15% after 12 months of follow-up. Good correlation between electrical and mechanical timings was found in patients with normal left ventricular function (r(2) = 0.88; P = .005) but not in those with left ventricular dysfunction (r(2) = 0.02; P = not significant). After therapy, both timings and sequences were modified and improved, except in those with myocardial scar. Despite a close electromechanical relationship in normal left ventricular function, there is no significant correlation in patients with dysfunction. Although resynchronization therapy improves this correlation, the changes in electrical activation may not yield similar changes in left ventricular mechanics particularly depending on the underlying myocardial substrate. Copyright © 2013 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.
Yue-Chun, Li; Jia-Feng, Lin; Jia-Xuan, Lin
2015-10-01
Electrocardiographic characteristics can be useful in differentiating between right ventricular outflow tract (RVOT) and aortic sinus cusp (ASC) ventricular arrhythmias. Ventricular arrhythmias originating from ASC, however, show preferential conduction to RVOT that may render the algorithms of electrocardiographic characteristics less reliable. Even though there are few reports describing ventricular arrhythmias with ASC origins and endocardial breakout sites of RVOT, progressive dynamic changes in QRS morphology of the ventricular arrhythmias during ablation obtained were rare.This case report describes a patient with symptomatic premature ventricular contractions of left ASC origin presenting an electrocardiogram (ECG) characteristic of right ventricular outflow tract before ablation. Pacing at right ventricular outflow tract reproduced an excellent pace map. When radiofrequency catheter ablation was applied to the right ventricular outflow tract, the QRS morphology of premature ventricular contractions progressively changed from ECG characteristics of right ventricular outflow tract origin to ECG characteristics of left ASC origin.Successful radiofrequency catheter ablation was achieved at the site of the earliest ventricular activation in the left ASC. The distance between the successful ablation site of the left ASC and the site with an excellent pace map of the RVOT was 20 mm.The ndings could be strong evidence for a preferential conduction via the myocardial bers from the ASC origin to the breakout site in the right ventricular outflow tract. This case demonstrates that ventricular arrhythmias with a single origin and exit shift may exhibit QRS morphology changes.
Milks, Michael Wesley; Upadhya, Bharathi; Hall, Michael E; Vasu, Sujethra; Hundley, William Gregory; Stacey, Richard Brandon
2015-01-01
The assessment of right ventricular (RV) perfusion defects has remained challenging during vasodilator stress perfusion with cardiovascular magnetic resonance (CMR). The significance of RV signal abnormalities during vasodilator stress perfusion and late gadolinium-enhanced CMR is yet uncertain. Among 61 individuals who underwent adenosine CMR stress testing before cardiac catheterization, we assessed the severity of coronary artery stenoses, mortality, the presence of stress and rest perfusion defects, as well as the presence of late gadolinium enhancement (LGE). Right ventricular stress-induced perfusion defects were positively associated with left anterior descending artery and proximal right coronary artery stenoses but were negatively associated with left circumflex artery stenoses. The presence of RVLGE was associated with mortality, but 77% of those with RVLGE also had left ventricular LGE. Proximal right coronary artery and left anterior descending artery stenoses are positively associated, whereas left circumflex artery stenoses are negatively associated with RV stress-induced perfusion defects. Right ventricular LGE was associated with mortality, but further study is needed to determine whether this is independent of left ventricular LGE.
Javaheri, Sogol; Sharma, Ravi K; Bluemke, David A; Redline, Susan
2017-08-01
We assessed whether the presence of central sleep apnea is associated with adverse left ventricular structural changes. We analysed 1412 participants from the Multi-Ethnic Study of Atherosclerosis who underwent both overnight polysomnography and cardiac magnetic resonance imaging. Subjects had been recruited 10 years earlier when free of cardiovascular disease. Our main exposure is the presence of central sleep apnea as defined by central apnea-hypopnea index = 5 or the presence of Cheyne-Stokes breathing. Outcome variables were left ventricular mass/height, left ventricular ejection fraction, and left ventricular mass/volume ratio. Multivariate linear regression models adjusted for age, gender, race, waist circumference, tobacco use, hypertension, and the obstructive apnea-hypopnea index were fit for the outcomes. Of the 1412 participants, 27 (2%) individuals had central sleep apnea. After adjusting for covariates, the presence of central sleep apnea was significantly associated with elevated left ventricular mass/volume ratio (β = 0.11 ± 0.04 g mL -1 , P = 0.0071), an adverse cardiac finding signifying concentric remodelling. © 2017 European Sleep Research Society.
[Blood pressure variability and left ventricular hypertrophy in arterial hypertension].
Amodeo, C; Martins, S M; Silva Júnior, O; Barros, L M; Batlouni, M; Sousa, J E
1993-05-01
To evaluate the left ventricular hypertrophy correlation with blood pressure variability during day and night time as well as throughout the 24h period. Fifteen patients with mild to moderate essential hypertension underwent to bi-dimensional echocardiographic study and to 24h ambulatory blood pressure monitorization. Left ventricular mass was calculated according to previous validated formulas. The standard deviation of the mean blood pressures during day-time, night-time and 24h period was taken as blood pressure variability indices. The mean age of the group was 42 years old; 9 patients were male and all were white. This study showed that only the systolic and diastolic blood pressure variability during the 24h period correlated significantly with left ventricular mass, (r = 0.53 and p < 0.05; r = 0.58 and p < 0.05 respectively). There was no significant correlation of the day-time and night-time pressures variability with left ventricular mass. The systolic and diastolic blood pressure variability during the 24h period may be one of the many determinants of left ventricular hypertrophy in patients with mild to moderate hypertension.
Surgical myocardial revascularization in patients with reduced systolic left ventricular function.
Bruno, Piergiorgio; Iafrancesco, Mauro; Massetti, Massimo
2018-04-20
Surgical myocardial revascularization in patients with reduced left ventricular function has been a matter of debate for decades. Recently published 10-years extension follow-up of the STICH trial have conclusively demonstrated benefit of surgical myocardial revascularization in patients with significant coronary artery disease and low left ventricular ejection fraction. However, selection of patients for surgery remains challenging as well as decision to perform percutaneous rather than surgical revascularization in this class of patients. New evidence helped to clarify the role of preoperative patients' characteristics as risk factors for surgery and to identify those patients who may benefit the most from surgery. Focus of this review is to review epidemiology, aetiology and pathophysiology of coronary artery disease in patients with reduced left ventricular function, role of viability and results of observational and investigational studies on revascularization in patients with reduced left ventricular function with a particular emphasis on relative indication of coronary artery bypass grafting and percutaneous coronary intervention and the surgical implications of development of ischemic mitral regurgitation or ischemic left ventricular aneurysm.
Particle tracking velocimetry using echocardiographic data resolves flow in the left ventricle
NASA Astrophysics Data System (ADS)
Sampath, Kaushik; Abd, Thura T.; George, Richard T.; Katz, Joseph
2015-11-01
Two dimensional contrast echocardiography was performed on patients with a history of left ventricular (LV) thrombus. The 636 x 434 pixels electrocardiograms were recorded using a GE Vivid 9E system with (M5S-D and 4V-D) probes in a 2-D mode at a magnification of 0.3 mm/pix. The concentration of 2-4.5 micron seed bubbles was adjusted to obtain individually discernable traces, and a data acquisition rate of 60-90 fps kept the inter-frame displacements suitable for matching traces, and calculating vectors, but yet low enough to allow a scanning depth and width of upto 13 cm and 60 degrees respectively. Particle tracking velocimetry (PTV) guided by initial particle image velocimetry (PIV) was used to obtain the velocity distributions inside the LV with vector spacing of 3-5 mm. The data quality was greatly enhanced by implementing an iterative particle specific enhancement and tracking algorithm. Data covering 20 heart beats facilitated phase averaging. The results elucidated blood flow in the intra-ventricular septal region, lateral wall region, the apex of the LV and the mitral valve region.
Jennings, Douglas L; Chambers, Rachel M; Schillig, Jessica M
2010-10-01
Advanced heart failure continues to be a significant cause of morbidity and mortality in the US. Patients with advanced heart failure have a poor prognosis without cardiac transplantation. The use of left ventricular assist devices (LVADs) as destination therapy for these patients is therefore expected to increase in the coming years as technology advances. The HeartMate II, a continuous flow implantable device, is currently the only LVAD that has been approved by the Food and Drug Administration for destination therapy in patients with advanced heart failure. The pharmacotherapy associated with this device is very complex and, therefore, the need for expertly trained clinical pharmacists to care for this expanding patient population will also likely increase. Unfortunately, most pharmacists are unfamiliar with the effect of LVADs on the physiology and pharmacotherapy of a patient's heart failure. The purpose of this article is to give clinical pharmacists an introduction to the most common pharmacotherapeutic issues for patients with LVADs and present practical solutions for managing common drug therapy problems.
Urbano-Moral, Jose Angel; Gangadharamurthy, Dakshin; Comenzo, Raymond L; Pandian, Natesa G; Patel, Ayan R
2015-08-01
The study of myocardial mechanics has a potential role in the detection of cardiac involvement in patients with amyloidosis. This study aimed to characterize 3-dimensional-speckle tracking echocardiography-derived left and right ventricular myocardial mechanics in light chain amyloidosis and examine their relationship with brain natriuretic peptide. In patients with light chain amyloidosis, left ventricular longitudinal and circumferential strain (n=40), and right ventricular longitudinal strain and radial displacement (n=26) were obtained by 3-dimensional-speckle tracking echocardiography. Brain natriuretic peptide levels were determined. All myocardial mechanics measurements showed differences when compared by brain natriuretic peptide level tertiles. Left and right ventricular longitudinal strain were highly correlated (r=0.95, P<.001). Left ventricular longitudinal and circumferential strain were reduced in patients with cardiac involvement (-9±4 vs -16±2; P<.001, and -24±6 vs -29±4; P=.01, respectively), with the most prominent impairment at the basal segments. Right ventricular longitudinal strain and radial displacement were diminished in patients with cardiac involvement (-9±3 vs -17±3; P<.001, and 2.7±0.8 vs 3.8±0.3; P=.002). On multivariate analysis, left ventricular longitudinal strain was associated with the presence of cardiac involvement (odds ratio = 1.6; 95% confidence interval, 1.04 to 2.37; P=.03) independent of the presence of brain natriuretic peptide and troponin I criteria for cardiac amyloidosis. Three-dimensional-speckle tracking echocardiography-derived left and right ventricular myocardial mechanics are increasingly altered as brain natriuretic peptide increases in light chain amyloidosis. There appears to be a strong association between left ventricular longitudinal strain and cardiac involvement, beyond biomarkers such as brain natriuretic peptide and troponin I. Copyright © 2015 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.
Gauna, A; Messuti, H; Papadopulos, G; Benchuga, G; Viale, F; Marlowe, R J; Silva Croome, M C
2011-10-01
How the duration of hypothyroidism affects left ventricular diastolic function is not well-characterized. We sought to compare left ventricular diastolic function in acutely vs chronically hypothyroid patients vs euthyroid controls, and within individuals while on vs off T4. We prospectively performed such comparisons measuring pulsed-wave and color M-mode Doppler echocardiographic variables: early or late mitral peak velocities (E wave or A wave, respectively), E wave/A wave ratio, E wave deceleration time, isovolumic relaxation time (IVRT), mitral flow propagation velocity (Vp), E wave/Vp ratio. Subjects comprised the acute HYPO group, 10 patients undergoing T4 withdrawal ≥ 6 months post-primary treatment for differentiated thyroid cancer (DTC); the chronic HYPO group, 23 treatment-naïve Hashimoto thyroiditis patients; and 21 healthy euthyroid controls. Subjects were adults aged ≤ 60 yr, predominantly female, with sinus rhythm; exclusion criteria were cardiovascular or thyroid disorder besides DTC (Hashimoto thyroiditis) in acute (chronic) HYPO patients or medication (besides thyroid hormone) affecting cardiac or thyroid function. Mean IVRT was significantly delayed and mean Vp, significantly slowed in both HYPO groups vs controls (p<0.0005), but did not differ between HYPO groups. These variables also were significantly impaired (p<0.05) within individuals when off vs on T4 (no.=8 acute, 10 chronic HYPO patients). Both HYPO groups had elevated mean E wave/Vp ratios vs controls, but the elevation reached significance (p<0.05) only in the larger chronic HYPO group. Left ventricular diastolic dysfunction is largely similar in acutely or chronically hypothyroid patients off T4 vs healthy controls or the same patients on T4.
77-year-old female with syncope.
Abdelsalam, Mahmoud A; Geske, Jeffrey B
2017-02-15
A 77-year-old female was referred for evaluation of an episode of syncope while eating breakfast. There was no history of fall, syncope, prodrome, dyspnoea, chest discomfort or palpitations. Medical history was notable for hyperlipidaemia and treated hypertension. Blood pressure was 140/90 mm Hg, pulse 85 beats per minute (BPM). No murmurs were present on cardiac examination. ECG revealed normal sinus rhythm with left ventricular (LV) hypertrophy (see online supplementary figure S1). Holter monitor demonstrated rare premature ventricular complexes (<1% of beats), without heart block or ventricular tachycardia. Transthoracic echocardiogram is shown in figure 1. Which of the following is the explanation for the flow indicated by the yellow arrow? Aortic stenosisCoronary artery flow, indicative of coronary fistulaHypertrophic cardiomyopathy with apical pouchHypertensive heart diseaseMitral stenosis. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Hearts, neck posture and metabolic intensity of sauropod dinosaurs.
Seymour, R S; Lillywhite, H B
2000-01-01
Hypothesized upright neck postures in sauropod dinosaurs require systemic arterial blood pressures reaching 700 mmHg at the heart. Recent data on ventricular wall stress indicate that their left ventricles would have weighed 15 times those of similarly sized whales. Such dimensionally, energetically and mechanically disadvantageous ventricles were highly unlikely in an endothermic sauropod. Accessory hearts or a siphon mechanism, with sub-atmospheric blood pressures in the head, were also not feasible. If the blood flow requirements of sauropods were typical of ectotherms, the left-ventricular blood volume and mass would have been smaller; nevertheless, the heart would have suffered the serious mechanical disadvantage of thick walls. It is doubtful that any large sauropod could have raised its neck vertically and endured high arterial blood pressure, and it certainly could not if it had high metabolic rates characteristic of endotherms. PMID:11052540
2014-01-01
Background Many pathologies seen in the preterm population are associated with abnormal blood supply, yet robust evaluation of preterm cardiac function is scarce and consequently normative ranges in this population are limited. The aim of this study was to quantify and validate left ventricular dimension and function in preterm infants using cardiovascular magnetic resonance (CMR). An initial investigation of the impact of the common congenital defect patent ductus arteriosus (PDA) was then carried out. Methods Steady State Free Procession short axis stacks were acquired. Normative ranges of left ventricular end diastolic volume (EDV), stroke volume (SV), left ventricular output (LVO), ejection fraction (EF), left ventricular (LV) mass, wall thickness and fractional thickening were determined in “healthy” (control) neonates. Left ventricular parameters were then investigated in PDA infants. Unpaired student t-tests compared the 2 groups. Multiple linear regression analysis assessed impact of shunt volume in PDA infants, p-value ≤ 0.05 being significant. Results 29 control infants median (range) corrected gestational age at scan 34+6(31+1-39+3) weeks were scanned. EDV, SV, LVO, LV mass normalized by weight and EF were shown to decrease with increasing corrected gestational age (cGA) in controls. In 16 PDA infants (cGA 30+3(27+3-36+1) weeks) left ventricular dimension and output were significantly increased, yet there was no significant difference in ejection fraction and fractional thickening between the two groups. A significant association between shunt volume and increased left ventricular mass correcting for postnatal age and corrected gestational age existed. Conclusion CMR assessment of left ventricular function has been validated in neonates, providing more robust normative ranges of left ventricular dimension and function in this population. Initial investigation of PDA infants would suggest that function is relatively maintained. PMID:25160730
Chen, Peter C; Spinner, Joseph A; Heinle, Jeffrey S
2018-07-01
We report a 1-month-old infant diagnosed with an aorta-left ventricular tunnel, ventricular septal defect, and right coronary atresia with right ventricular sinusoids. The patient's anatomy and physiology did not indicate right-ventricular-dependent coronary circulation, and therefore right ventricular decompression could be performed without compromising coronary perfusion during surgical correction. A detailed understanding of the coronary anatomy is critical in managing this defect when coronary anomalies are present.
Long-term in vivo left ventricular assist device study with a titanium centrifugal pump.
Ohtsuka, G; Nakata, K; Yoshikawa, M; Mueller, J; Takano, T; Yamane, S; Gronau, N; Glueck, J; Takami, Y; Sueoka, A; Letsou, G; Schima, H; Schmallegger, H; Wolner, E; Koyanagi, H; Fujisawa, A; Baldwin, J C; Nosé, Y
1998-01-01
A totally implantable centrifugal artificial heart has been developed. The plastic prototype, Gyro PI 601, passed 2 day hemodynamic tests as a functional total artificial heart, 2 week screening tests for antithrombogenicity, and 1 month system feasibility. Based on these results, a metallic prototype, Gyro PI 702, was subjected to in vivo left ventricular assist device (LVAD) studies. The pump system employed the Gyro PI 702, which has the same inner dimensions and the same characteristics as the Gyro PI 601, including an eccentric inlet port, a double pivot bearing system, and a magnet coupling system. The PI 702 is driven with the Vienna DC brushless motor actuator. For the in vivo LVAD study, the pump actuator package was implanted in the preperitoneal space in two calves, from the left ventricular apex to the descending aorta. Case 1 achieved greater than 9 month survival without any complications, at an average flow rate of 6.6 L/min with 10.2 W input power. Case 2 was killed early due to the excessive growth of the calf, which caused functional obstruction of the inlet port. There was no blood clot inside the pump. During these periods, neither case exhibited any physiologic abnormalities. The PI 702 pump gives excellent results as a long-term implantable LVAD.
Tsiouris, Athanasios; Paone, Gaetano; Nemeh, Hassan W; Brewer, Robert J; Borgi, Jamil; Hodari, Arielle; Morgan, Jeffrey A
2015-01-01
Continuous-flow (CF) left ventricular assist devices (LVADs) have become the standard of care for patients with advanced heart failure refractory to optimal medical therapy. The goal of this study was to review our 7 year single institutional experience with CF LVADs. Mean age was 50.4 + 12.5 (17-69) years for bridge-to-transplantation (BTT) patients and 57.6 + 10.4 (31-81) years for destination therapy (DT) patients (p < 0.001). Overall, 38 patients (26%) were female and 58 (41%) were African American. Etiology of heart failure was ischemic in 54 patients (37%) and nonischemic in 93 patients (63%). Overall survival at 30 days, 6 months, 12 months, and 2 years was 93%, 89%, 84%, and 81%, respectively. Gastrointestinal bleeding (GIB) was the most common complication (24%), followed by stroke (18%), right ventricular (RV) failure (18%), ventilator-dependent respiratory failure (10%), reoperation for bleeding (10%), and driveline infection (9%). These data demonstrate excellent survival with low mortality for both BTT and DT patients on long-term LVAD support. However, for LVAD therapy to become the gold standard for long-term treatment of end-stage heart failure and a plausible alternative to heart transplantation, we need to continue to improve the incidence of frequent postoperative complications, such as RV failure, driveline infections, strokes, and GIB.
Sintek, Marc A.; Gdowski, Mark; Lindman, Brian R.; Nassif, Michael; Lavine, Kory J.; Novak, Eric; Bach, Richard G.; Silvestry, Scott C.; Mann, Douglas L.; Joseph, Susan M.
2015-01-01
Objective To characterize the clinical response and identify predictors of clinical stabilization after intra-aortic balloon counterpulsation (IABP) support in patients with chronic systolic heart failure in cardiogenic shock prior to implantation of a left ventricular assist device (LVAD). Background Limited data exist regarding the clinical response to IABP in patients with chronic heart failure in cardiogenic shock. Methods We identified 54 patients supported with IABP prior to LVAD implantation. Criteria for clinical decompensation after IABP insertion and before LVAD included the need for more advanced temporary support, initiation of mechanical ventilation or dialysis, increase in vasopressors/inotropes, refractory ventricular arrhythmias, or worsening acidosis. The absence of these indicated stabilization. Results Clinical decompensation after IABP occurred in 23 (43%) patients. Both patients who decompensated and those who stabilized had similar hemodynamic improvements after IABP support but patients who decompensated required more vasopressors/inotropes. Clinical decompensation after IABP was associated with worse outcomes after LVAD implantation, including a 3-fold longer intensive care unit stay and 5-fold longer time on mechanical ventilation (p<0.01 for both). While baseline characteristics were similar between groups, right and left ventricular cardiac power indices (Cardiac power Index= Cardiac Index × Mean arterial pressure / 451)identified patients who were likely to stabilize (AUC=0.82). Conclusions Among patients with chronic systolic heart failure who develop cardiogenic shock, more than half of patients stabilized with IABP support as a bridge to LVAD. Baseline measures of right and left ventricular cardiac power, both measures of work performed for a given flow and pressure, may allow clinicians to identify patients with sufficient contractile reserve who will be likely to stabilize with an IABP versus those who may need more aggressive ventricular support. PMID:26164215
Grupper, Avishay; Park, Soon J; Pereira, Naveen L; Schettle, Sarah D; Gerber, Yariv; Topilsky, Yan; Edwards, Brooks S; Daly, Richard C; Stulak, John M; Joyce, Lyle D; Kushwaha, Sudhir S
2015-08-01
Restrictive cardiomyopathy (RCM) patients have poor prognosis due to progressive heart failure characterized by impaired ventricular filling of either or both ventricles. The goal of this study was to evaluate the outcome of end-stage RCM patients after left ventricular assist device (LVAD) implantation and to determine factors that may be associated with improved survival. This investigation is a retrospective study of prospectively collected data that include 28 consecutive patients with end-stage RCM who received continuous-flow LVADs at the Mayo Clinic, Rochester, Minnesota. Outcome was assessed by survival with LVAD support until heart transplantation or all-cause mortality. The mean follow-up time post-LVAD implantation was 448 ± 425 days. The mean hospitalization time was 29 ± 19 days and was complicated mainly by post-operative right ventricular (RV) failure requiring short-term medical support. The short-term in-hospital mortality was 14%. Ten patients underwent heart transplantation with 100% survival post-transplant during the follow-up period. One-year survival for patients with LVADs without transplantation was 64%, and was not significantly different between amyloidosis and non-amyloidosis patients. Larger left ventricle (LV) end-diastolic and end-systolic dimensions were significantly associated with improved survival rates (RR = 0.94 and 0.95, p < 0.05, respectively), and left ventricular end-diastolic diameter (LVEDD) ≤46 mm was associated with increased mortality post-LVAD implantation. LVAD is a feasible, life-saving therapy for end-stage heart failure related to RCM, especially as a bridge to transplant and in patients with larger LV dimensions. Copyright © 2015 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.
Longitudinal analysis of head and somatic growth in fetuses with congenital heart defects.
Turan, Sifa; Rosenbloom, Joshua I; Hussein, Mostafa; Berg, Christoph; Gembruch, Ulrich; Baschat, Ahmet A; Turan, Ozhan M
2017-02-01
Fetal head and somatic growth dynamics differs in fetuses with congenital heart defects (CHD). We longitudinally characterized fetal head and somatic growth in relation to the type of CHD. Four hundred eleven exams from isolated CHD were compared with 1,219 controls. Head and somatic growth was assessed using head circumference (HC), brain volume (BrV = 1/6 × π × (HC/π)3)/2), fetal cephalization index (FCI = BrV/[estimated fetal weight]), and growth percentile. Umbilical and middle cerebral artery Doppler indices were obtained. CHD were grouped as: (1) d-transposition of great arteries (n = 11); (2) left ventricular outflow tract obstruction with retrograde isthmic flow (n = 18); (3) left ventricular outflow tract obstruction with antegrade isthmic flow (n = 16); (4) pulmonary outflow tract obstructions (n = 22). The smallest head size was seen in group 1. Growth asymmetry was diagnosed in group 2. Brain sparing was seen in groups 2 and 4 (p < 0.0001). HC and BrV percentiles decreased with advancing gestational age (p < 0.001) in group 2, and a significant drop was observed around 28 weeks. d-Transposition of great arteries and left-sided CHD leading to isthmic blood flow reversal are associated with delayed head growth. Prenatal evaluation of central hemodynamics in CHD may be contributive for predicting neurodevelopmental risks in CHD and help directing prenatal interventions. © 2016 Wiley Periodicals, Inc. J Clin Ultrasound 45:96-104, 2017. © 2016 Wiley Periodicals, Inc.
Wang, Shan-Shan; Hong, Wen-Jing; Zhang, Yu-Qi; Chen, Shu-Bao; Huang, Guo-Ying; Zhang, Hong-Yan; Chen, Li-Jun; Wu, Lan-Ping; Shen, Rong; Liu, Yi-Qing; Zhu, Jun-Xue
2018-06-01
Clinical decision making in children with heart disease relies on detailed measurements of cardiac structures using two-dimensional and M-mode echocardiography. However, no echocardiographic reference values are available for the Chinese children. We aimed to establish z-score regression equations for left heart structures in a population-based cohort of healthy Chinese Han children. Echocardiography was performed in 545 children with a normal heart. The dimensions of the aortic valve annulus (AVA), aortic sinuses of Valsalva (ASV), sinotubular junction (STJ), ascending aorta (AAO), left atrium (LA), mitral valve annulus (MVA), interventricular septal end-diastolic thickness (IVSd), interventricular septal end-systolic thickness (IVSs), left ventricular end-diastolic diameter (LVIDd), left ventricular end-systolic diameter (LVIDs), left ventricular posterior wall end-diastolic thickness (LVPWd), left ventricular posterior wall end-systolic thickness (LVPWs) were measured. Regression analyses were conducted to relate the measurements of left heart structures to body surface area (BSA). Left ventricular ejection fraction (LVEF) and left ventricular fractional shortening (LVFS) were calculated. Several models were used, and the adjusted R2 values were compared for each model. AVA, ASV, STJ, AAO, LA, MVA, IVSd, IVSs, LVIDd, LVIDs, LVPWd, and LVPWs had a cubic relationship with BSA. LVEF and LVFS fell within a narrow range. Our results provide reference values for z scores and regression equations for left heart structures in Han Chinese children. These data may help make a quick and accurate judgment of the routine clinical measurement of left heart structures in children with heart disease. © 2018 Wiley Periodicals, Inc.
[Rare cause of heart failure in an elderly woman in Djibouti: left ventricular non compaction].
Massoure, P L; Lamblin, G; Bertani, A; Eve, O; Kaiser, E
2011-10-01
The purpose of this report is to describe the first case of left ventricular non compaction diagnosed in Djibouti. The patient was a 74-year-old Djiboutian woman with symptomatic heart failure. Echocardiography is the key tool for assessment of left ventricular non compaction. This rare cardiomyopathy is probably underdiagnosed in Africa.
Bleeding with the artificial heart: Gastrointestinal hemorrhage in CF-LVAD patients.
Gurvits, Grigoriy E; Fradkov, Elena
2017-06-14
Continuous-flow left ventricular assist devices (CF-LVADs) have significantly improved outcomes for patients with end-stage heart failure when used as a bridge to cardiac transplantation or, more recently, as destination therapy. However, its implantations carries a risk of complications including infection, device malfunction, arrhythmias, right ventricular failure, thromboembolic disease, postoperative and nonsurgical bleeding. A significant number of left ventricular assist devices (LVAD) recipients may experience recurrent gastrointestinal hemorrhage, mainly due to combination of antiplatelet and vitamin K antagonist therapy, activation of fibrinolytic pathway, acquired von Willebrand factor deficiency, and tendency to develop small intestinal angiodysplasias due to increased rotary speed of the pump. Gastrointestinal bleeding in LVAD patients remains a source of increased morbidity including the need for blood transfusions, extended hospital stays, multiple readmissions, and overall mortality. Management of gastrointestinal bleeding in LVAD patients involves multidisciplinary approach in stabilizing the patients, addressing risk factors and performing structured endoluminal evaluation with focus on upper gastrointestinal tract including jejunum to find and eradicate culprit lesion. Medical and procedural intervention is largely successful and universal bleeding cessation occurs in transplanted patients.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rakovec, P.; Kranjec, I.; Fettich, J.J.
1985-01-01
Coinciding left bundle-branch block and Wolff-Parkinson-White syndrome type B, a very rare electrocardiographic occurrence, was found in a patient with dilated cardiomyopathy. Electrophysiologic study revealed eccentric retrograde atrial activation during ventricular pacing, suggesting right-sided accessory pathway. At programmed atrial pacing, effective refractory period of the accessory pathway was 310 ms; at shorter pacing coupling intervals, normal atrioventricular conduction with left bundle-branch block was seen. Left bundle-branch block was seen also with His bundle pacing. Radionuclide phase imaging demonstrated right ventricular phase advance and left ventricular phase delay; both right and left ventricular phase images revealed broad phase distribution histograms. Combinedmore » electrophysiologic and radionuclide investigations are useful to disclose complex conduction abnormalities and their mechanical correlates.« less
Erol, Cengiz; Koplay, Mustafa; Olcay, Ayhan; Kivrak, Ali Sami; Ozbek, Seda; Seker, Mehmet; Paksoy, Yahya
2012-11-01
Our aim was to evaluate congenital left ventricular wall abnormalities (clefts, aneurysms and diverticula), describe and illustrate imaging features, discuss terminology problems and determine their prevalence detected by cardiac CT in a single center. Coronary CT angiography images of 2093 adult patients were evaluated retrospectively in order to determine congenital left ventricular wall abnormalities. The incidence of left ventricular clefts (LVC) was 6.7% (141 patients) and statistically significant difference was not detected between the sexes regarding LVC (P=0.5). LVCs were single in 65.2% and multiple in 34.8% of patients. They were located at the basal to mid inferoseptal segment of the left ventricle in 55.4%, the basal to mid anteroseptal segment in 24.1%, basal to mid inferior segment in 17% and septal-apical septal segment in 3.5% of cases. The cleft length ranged from 5 to 22 mm (mean 10.5 mm) and they had a narrow connection with the left ventricle (mean 2.5 mm). They were contractile with the left ventricle and obliterated during systole. Congenital left ventricular septal aneurysm that was located just under the aortic valve was detected in two patients (0.1%). No case of congenital left ventricular diverticulum was detected. Cardiac CT allows us to recognize congenital left ventricular wall abnormalities which have been previously overlooked in adults. LVC is a congenital structural variant of the myocardium, is seen more frequently than previously reported and should be differentiated from aneurysm and diverticulum for possible catastrophic complications of the latter two. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Masked hypertension and cardiac remodeling in middle-aged endurance athletes.
Trachsel, Lukas D; Carlen, Frederik; Brugger, Nicolas; Seiler, Christian; Wilhelm, Matthias
2015-06-01
Extensive endurance training and arterial hypertension are established risk factors for atrial fibrillation. We aimed to assess the proportion of masked hypertension in endurance athletes and the impact on cardiac remodeling, mechanics, and supraventricular tachycardias (SVT). Male participants of a 10-mile race were recruited and included if office blood pressure was normal (<140/90 mmHg). Athletes were stratified into a masked hypertension and normotension group by ambulatory blood pressure. Primary endpoint was diastolic function, expressed as peak early diastolic mitral annulus velocity (E'). Left ventricular global strain, left ventricular mass/volume ratio, left atrial volume index, signal-averaged P-wave duration (SAPWD), and SVT during 24-h Holter monitoring were recorded. From 108 runners recruited, 87 were included in the final analysis. Thirty-three (38%) had masked hypertension. The mean age was 42 ± 8 years. Groups did not differ with respect to age, body composition, cumulative training hours, and 10-mile race time. Athletes with masked hypertension had a lower E' and a higher left ventricular mass/volume ratio. Left ventricular global strain, left atrial volume index, SAPWD, and SVT showed no significant differences between the groups. In multiple linear regression analysis, masked hypertension was independently associated with E' (beta = -0.270, P = 0.004) and left ventricular mass/volume ratio (beta = 0.206, P = 0.049). Cumulative training hours was the only independent predictor for left atrial volume index (beta = 0.474, P < 0.001) and SAPWD (beta = 0.481, P < 0.001). In our study, a relevant proportion of middle-aged athletes had masked hypertension, associated with a lower diastolic function and a higher left ventricular mass/volume ratio, but unrelated to left ventricular systolic function, atrial remodeling, or SVT.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dhainaut, J.F.; Devaux, J.Y.; Monsallier, J.F.
1986-07-01
Continuous positive pressure ventilation is associated with a reduction in left ventricular preload and cardiac output, but the mechanisms responsible are controversial. The decrease in left ventricular preload may result exclusively from a decreased systemic venous return due to increased pleural pressure, or from an additional effect such as decreased left ventricular compliance. To determine the mechanisms responsible, we studied the changes in cardiac output induced by continuous positive pressure ventilation in eight patients with the adult respiratory distress syndrome. We measured cardiac output by thermodilution, and biventricular ejection fraction by equilibrium gated blood pool scintigraphy. Biventricular end-diastolic volumes weremore » then calculated by dividing stroke volume by ejection fraction. As positive end-expiratory pressure increased from 0 to 20 cm H/sub 2/O, stroke volume and biventricular end-diastolic volumes fell about 25 percent, and biventricular ejection fraction remained unchanged. At 20 cm H/sub 2/O positive end-expiratory pressure, volume expansion for normalizing cardiac output restored biventricular end-diastolic volumes without markedly changing biventricular end-diastolic transmural pressures. The primary cause of the reduction in left ventricular preload with continuous positive pressure ventilation appears to be a fall in venous return and hence in right ventricular stroke volume, without evidence of change in left ventricular diastolic compliance.« less
Oiwa, H; Kawauchi, M; Chikada, M; Yagyu, K; Kotsuka, Y; Furuse, A
1995-01-01
A pulsatile total cavopulmonary shunt was successfully performed on a 5-year-old girl with hypoplastic right heart syndrome associated with abnormal systemic venous return; at the same time, modified mitral valve replacement was performed for mitral regurgitation. The right atrium, tricuspid valve and right ventricle were all extremely dimunitive. The diameter of the tricuspid valve was 50% of normal and the volume of the right ventricle was 8.6% of normal. In addition, there were severe subpumonary stenosis, a restrictive ventricular septal defect (VSD) and an atrial septal defect (ASD). The bilateral superior venae cavae (SVCs) and the hepatic vein drained to the left atrium, and the inferior vena cava was infrahepatically interrupted with a hemiazygos connection to the left superior vena cava. At the operation, each SVC was anastomosed end-to-side to each branch of the pulmonary artery (PA). The restrictive ventricular septal defect and stenotic subpulmonary lesion were left. The diameter of the ASD was reduced from 12 mm to 7 mm. The main PA was neither divided nor banded. The pulsatile blood flow from the left heart to the PA was regurated by a native restrictive VSD and stenotic subpulmonary lesion, and that from the right heart via the ASD was limited by reducing the size of the ASD. These described anatomic arrangements produced adequate antegrade pulsatile flow in the PA, which might prevent the development of pulmonary arteriovenous fistulae and, besides permit transfer of drainage of the hepatic vein from the left to the right atrium via the ASD in future.
Kinematic, Dynamic, and Energy Characteristics of Diastolic Flow in the Left Ventricle
Khalafvand, Seyed Saeid; Hung, Tin-Kan; Ng, Eddie Yin-Kwee; Zhong, Liang
2015-01-01
Blood flow characteristics in the normal left ventricle are studied by using the magnetic resonance imaging, the Navier-Stokes equations, and the work-energy equation. Vortices produced during the mitral valve opening and closing are modeled in a two-dimensional analysis and correlated with temporal variations of the Reynolds number and pressure drop. Low shear stress and net pressures on the mitral valve are obtained for flow acceleration and deceleration. Bernoulli energy flux delivered to blood from ventricular dilation is practically balanced by the energy influx and the rate change of kinetic energy in the ventricle. The rates of work done by shear and energy dissipation are small. The dynamic and energy characteristics of the 2D results are comparable to those of a 3D model. PMID:26417381
Weber, Thomas; Wassertheurer, Siegfried; Schmidt-Trucksäss, Arno; Rodilla, Enrique; Ablasser, Cornelia; Jankowski, Piotr; Lorenza Muiesan, Maria; Giannattasio, Cristina; Mang, Claudia; Wilkinson, Ian; Kellermair, Jörg; Hametner, Bernhard; Pascual, Jose Maria; Zweiker, Robert; Czarnecka, Danuta; Paini, Anna; Salvetti, Massimo; Maloberti, Alessandro; McEniery, Carmel
2017-12-01
We investigated the relationship between left ventricular mass and brachial office as well as brachial and central ambulatory systolic blood pressure in 7 European centers. Central systolic pressure was measured with a validated oscillometric device, using a transfer function, and mean/diastolic pressure calibration. M-mode images were obtained by echocardiography, and left ventricular mass was determined by one single reader blinded to blood pressure. We studied 289 participants (137 women) free from antihypertensive drugs (mean age: 50.8 years). Mean office blood pressure was 145/88 mm Hg and mean brachial and central ambulatory systolic pressures were 127 and 128 mm Hg, respectively. Mean left ventricular mass was 93.3 kg/m 2 , and 25.6% had left ventricular hypertrophy. The correlation coefficient between left ventricular mass and brachial office, brachial ambulatory, and central ambulatory systolic pressure was 0.29, 0.41, and 0.47, respectively ( P =0.003 for comparison between brachial office and central ambulatory systolic pressure and 0.32 for comparison between brachial and central ambulatory systolic pressure). The results were consistent for men and women, and young and old participants. The areas under the curve for prediction of left ventricular hypertrophy were 0.618, 0.635, and 0.666 for brachial office, brachial, and central ambulatory systolic pressure, respectively ( P =0.03 for comparison between brachial and central ambulatory systolic pressure). In younger participants, central ambulatory systolic pressure was superior to both other measurements. Central ambulatory systolic pressure, measured with an oscillometric cuff, shows a strong trend toward a closer association with left ventricular mass and hypertrophy than brachial office/ambulatory systolic pressure. URL: https://www.clinicaltrials.gov. Unique identifier: NCT01278732. © 2017 American Heart Association, Inc.
Ahmad, Faraz S; Cai, Xuan; Kunkel, Katherine; Ricardo, Ana C; Lash, James P; Raj, Dominic S; He, Jiang; Anderson, Amanda H; Budoff, Matthew J; Wright Nunes, Julie A; Roy, Jason; Wright, Jackson T; Go, Alan S; St John Sutton, Martin G; Kusek, John W; Isakova, Tamara; Wolf, Myles; Keane, Martin G
2017-08-01
Chronic kidney disease (CKD) is associated with increased risk of cardiovascular disease (CVD) and it is especially common among Blacks. Left ventricular hypertrophy (LVH) is an important subclinical marker of CVD, but there are limited data on racial variation in left ventricular structure and function among persons with CKD. In a cross-sectional analysis of the Chronic Renal Insufficiency Cohort Study, we compared the prevalence of different types of left ventricular remodeling (concentric hypertrophy, eccentric hypertrophy, and concentric remodeling) by race/ethnicity. We used multinomial logistic regression to test whether race/ethnicity associated with different types of left ventricular remodeling independently of potential confounding factors. We identified 1,164 non-Hispanic Black and 1,155 non-Hispanic White participants who completed Year 1 visits with echocardiograms that had sufficient data to categorize left ventricular geometry type. Compared to non-Hispanic Whites, non-Hispanic Blacks had higher mean left ventricular mass index (54.7 ± 14.6 vs. 47.4 ± 12.2 g/m2.7; P < 0.0001) and prevalence of concentric LVH (45.8% vs. 24.9%). In addition to higher systolic blood pressure and treatment with >3 antihypertensive medications, Black race/ethnicity was independently associated with higher odds of concentric LVH compared to White race/ethnicity (odds ratio: 2.73; 95% confidence interval: 2.02, 3.69). In a large, diverse cohort with CKD, we found significant differences in left ventricular mass and hypertrophic morphology between non-Hispanic Blacks and Whites. Future studies will evaluate whether higher prevalence of LVH contribute to racial/ethnic disparities in cardiovascular outcomes among CKD patients. © American Journal of Hypertension, Ltd 2017. All rights reserved. For Permissions, please email: journals.permissions@oup.com
Inoue, Tomoaki; Sonoda, Noriyuki; Hiramatsu, Shinsuke; Kimura, Shinichiro; Ogawa, Yoshihiro; Inoguchi, Toyoshi
2018-02-01
Previous studies have shown that serum bilirubin concentration is inversely associated with the risk of cardiovascular disease. The relationship between serum bilirubin concentration and left ventricular geometry, however, has not been investigated in patients with diabetes mellitus. In this cohort study, 158 asymptomatic patients with type 2 diabetes mellitus without overt heart disease were enrolled. Left ventricular structure and function were assessed using echocardiography. Serum bilirubin concentration, glycemic control, lipid profile, and other clinical characteristics were evaluated, and their association with left ventricular geometry was determined. Patients with New York Heart Association Functional Classification greater than I, left ventricular ejection fraction less than 50%, history of coronary artery disease, severe valvulopathy, chronic atrial fibrillation, or creatinine clearance less than 30 ml/min, and those receiving insulin treatment, were excluded. Univariate analyses showed that relative wall thickness (RWT) was significantly correlated with diastolic blood pressure (P = 0.003), HbA1c (P = 0.024), total cholesterol (P = 0.043), urinary albumin (P = 0.023), and serum bilirubin concentration (P = 0.009). There was no association between left ventricular mass index and serum bilirubin concentration. Multivariate linear regression analysis showed that log RWT was positively correlated with diastolic blood pressure (P = 0.010) and that log RWT was inversely correlated with log bilirubin (P = 0.003). In addition, the patients with bilirubin less than 0.8 mg/dl had a higher prevalence of concentric left ventricular remodeling compared with those with bilirubin 0.8 mg/dl or more. Our study shows that the serum bilirubin concentration may be associated with the progression of concentric left ventricular remodeling in patients with type 2 diabetes mellitus.
Yam, Man-Ching; So, Hung-Kwan; Kwok, Sit-Yee; Lo, Fung-Cheung; Mok, Chi-Fung; Leung, Chuk-Kwan; Yip, Wai-Kwok; Sung, Yn-Tz
2018-06-01
In our previous study, the prevalence of childhood masked hypertension was 11%. This study aims to assess the left ventricular mass index of persistent masked hypertension and determine the factors of elevated left ventricular mass index in Hong Kong Chinese adolescents from a community cohort. Community prospective cohort study, follow-up of a case-control study in community. Patients with masked hypertension at baseline were invited to recheck ambulatory blood pressure for the persistence of masked hypertension. A total of 144 out of 165 patients with masked hypertension in the 2011/2012 ambulatory blood pressure survey consented to participate in the study. In all, 48 patients were found to have persistent masked hypertension by ambulatory blood pressure rechecking and were matched with normotensive controls by sex, age, and body height. The left ventricular mass (117.3±39.9 g versus 87.0±28.2 g versus 102.0±28.2 g) and left ventricular mass index (30.1±8.4 g/m2.7 versus 23.9±6.3 g/m2.7 versus 25.1±5.7 g/m2.7) were significantly higher in the persistent masked hypertension group (p<0.0001) compared with the patients without persistent masked hypertension and controls. In multivariate linear regression analysis, left ventricular mass index was found to be higher in male gender (β=4.874, p<0.0001) and the patients with persistent masked hypertension (β=2.796, p=0.003). In addition, left ventricular mass index was positively associated with body mass index z-score (β=3.045, p<0.0001) and low-density lipoprotein cholesterol concentration (β=1.634, p=0.015). Persistent masked hypertension in adolescents is associated with elevated left ventricular mass index.
Zheng, Huan; Xie, Nanzi; Xu, Huifeng; Huang, Junling; Xie, Xiaoyun; Luo, Ming
2016-03-01
We sought to investigate effects of supervised exercise training on left ventricular remodeling, left ventricular function and autonomic nervous system of hypertensive patients without medication. Fifty borderline and mildly hypertensive patients were enrolled and randomly divided into 2 groups (25 in each). Exercise group received a 4 months' exercise program, prescribed according to their first cardiopulmonary exercise tests, while the control group received routine dietary recommendation. All patients underwent noradrenalin assay, cardiopulmonary exercise tests and echocardiographic studies at enrollment and 4 month follow-up. At baseline no statistically difference between the two groups were observed in clinical characteristics, echographic variants or cardiopulmonary test index. Four months later, exercise group showed higher values of VO2peak, Powermax (max workload), AT (anaerobic threshold), VO2AT (VO2 at anaerobic threshold), tAT (time from beginning to anaerobic threshold) and heart rate recovery compared to the control group (P<0.05). Additionally, systolic/diastolic blood pressure decreased significantly in the exercise group compared to the control group (P<0.05). Moreover, there was significant reduction in left ventricular mass index in the exercise group (P<0.01), and there was also an inverse correlation between changes in left ventricular mass index and heart rate recovery (r=-0.52, P<0.01). Four-month exercise training in borderline and mildly hypertensive patients not only decreased their blood pressure levels, but also induced an improvement of exercise capability, left ventricular remodeling and heart rate recovery. Heart rate recovery improvement was significantly associated with decrease of left ventricular mass index, which indicated that favorable adjustment in autonomic nervous system of exercise training might be an important pathway to reverse left ventricular remodeling.
Screening for Fabry disease in left ventricular hypertrophy: documentation of a novel mutation.
Baptista, Ana; Magalhães, Pedro; Leão, Sílvia; Carvalho, Sofia; Mateus, Pedro; Moreira, Ilídio
2015-08-01
Fabry disease is a lysosomal storage disease caused by enzyme α-galactosidase A deficiency as a result of mutations in the GLA gene. Cardiac involvement is characterized by progressive left ventricular hypertrophy. To estimate the prevalence of Fabry disease in a population with left ventricular hypertrophy. The patients were assessed for the presence of left ventricular hypertrophy defined as a left ventricular mass index ≥ 96 g/m2 for women or ≥ 116 g/m2 for men. Severe aortic stenosis and arterial hypertension with mild left ventricular hypertrophy were exclusion criteria. All patients included were assessed for enzyme α-galactosidase A activity using dry spot testing. Genetic study was performed whenever the enzyme activity was decreased. A total of 47 patients with a mean left ventricular mass index of 141.1 g/m2 (± 28.5; 99.2 to 228.5 g/m2] were included. Most of the patients were females (51.1%). Nine (19.1%) showed decreased α-galactosidase A activity, but only one positive genetic test - [GLA] c.785G>T; p.W262L (exon 5), a mutation not previously described in the literature. This clinical investigation was able to establish the association between the mutation and the clinical presentation. In a population of patients with left ventricular hypertrophy, we documented a Fabry disease prevalence of 2.1%. This novel case was defined in the sequence of a mutation of unknown meaning in the GLA gene with further pathogenicity study. Thus, this study permitted the definition of a novel causal mutation for Fabry disease - [GLA] c.785G>T; p.W262L (exon 5).
Schroeder, Carsten; Chung, Jane M; Mackall, Judith A; Cakulev, Ivan T; Patel, Aaron; Patel, Sunny J; Hoit, Brian D; Sahadevan, Jayakumar
2018-06-14
The aim of the study was to study the feasibility, safety, and efficacy of transesophageal echocardiography-guided intraoperative left ventricular lead placement via a video-assisted thoracoscopic surgery approach in patients with failed conventional biventricular pacing. Twelve patients who could not have the left ventricular lead placed conventionally underwent epicardial left ventricular lead placement by video-assisted thoracoscopic surgery. Eight patients had previous chest surgery (66%). Operative positioning was a modified far lateral supine exposure with 30-degree bed tilt, allowing for groin and sternal access. To determine the optimal left ventricular location for lead placement, the left ventricular surface was divided arbitrarily into nine segments. These segments were transpericardially paced using a hand-held malleable pacing probe identifying the optimal site verified by transesophageal echocardiography. The pacing leads were screwed into position via a limited pericardiotomy. The video-assisted thoracoscopic surgery approach was successful in all patients. Biventricular pacing was achieved in all patients and all reported symptomatic benefit with reduction in New York Heart Association class from III to I-II (P = 0.016). Baseline ejection fraction was 23 ± 3%; within 1-year follow-up, the ejection fraction increased to 32 ± 10% (P = 0.05). The mean follow-up was 566 days. The median length of hospital stay was 7 days with chest tube removal between postoperative days 2 and 5. In patients who are nonresponders to conventional biventricular pacing, intraoperative left ventricular lead placement using anatomical and functional characteristics via a video-assisted thoracoscopic surgery approach is effective in improving heart failure symptoms. This optimized left ventricular lead placement is feasible and safe. Previous chest surgery is no longer an exclusion criterion for a video-assisted thoracoscopic surgery approach.
Endeward, Volker; Gros, Gerolf; Jürgens, Klaus D
2010-07-01
The mechanisms by which the left ventricular wall escapes anoxia during the systolic phase of low blood perfusion are investigated, especially the role of myoglobin (Mb), which can (i) store oxygen and (ii) facilitate intracellular oxygen transport. The quantitative role of these two Mb functions is studied in the maximally working human heart. Because discrimination between Mb functions has not been achieved experimentally, we use a Krogh cylinder model here. At a heart rate of 200 beats/min and a 1:1 ratio of diastole/systole, the systole lasts for 150 ms. The basic model assumption is that, with mobile Mb, the oxygen stored in the end-diastolic left ventricle wall exactly meets the demand during the 150 ms of systolic cessation of blood flow. The coronary blood flow necessary to achieve this agrees with literature data. By considering Mb immobile or setting its concentration to zero, respectively, we find that, depending on Mb concentration, Mb-facilitated O(2) transport maintains O(2) supply to the left ventricle wall during 22-34 of the 150 ms, while Mb storage function accounts for a further 12-17 ms. When Mb is completely absent, anoxia begins to develop after 116-99 ms. While Mb plays no significant role during diastole, it supplies O(2) to the left ventricular wall for < or = 50 ms of the 150 ms systole, whereas capillary haemoglobin is responsible for approximately 80 ms. Slight increases in haemoglobin concentration, blood flow, or capillary density can compensate the absence of Mb, a finding which agrees well with the observations using Mb knockout mice.
Hochwald, Ori; Jabr, Mohammed; Osiovich, Horacio; Miller, Steven P.; McNamara, Patrick J.; Lavoie, Pascal M.
2015-01-01
Objective To determine the relationship between left ventricular cardiac output (LVCO), superior vena cava (SVC) flow, and brain injury during whole-body therapeutic hypothermia. Study design Sixteen newborns with moderate or severe hypoxic-ischemic encephalopathy were studied using echocardiography during and immediately after therapeutic hypothermia. Measures were also compared with 12 healthy newborns of similar postnatal age. Newborns undergoing therapeutic hypothermia also had a cerebral magnetic resonance imaging as part of routine clinical care on postnatal day 3–4. Results LVCO was markedly reduced (mean+/−SD: 126+/−38 mL/kg/min) during therapeutic hypothermia, whereas SVC flow was maintained within expected normal values (88+/− 27 mL/kg/min) such that it represented 70% of the LVCO. The reduction in LVCO during therapeutic hypothermia was mainly accounted by a reduction in heart rate (99 +/− 13 BPM versus 123 +/− 17 BPM; p<0.001) compared to immediately post-warming, in the context of myocardial dysfunction. Neonates with documented brain injury on MRI showed higher SVC flow pre-rewarming, compared to newborns without brain injury (p=0.013). Conclusion Newborns with perinatal hypoxic-ischemic encephalopathy showed a preferential systemic-to cerebral redistribution of cardiac blood flow during whole-body therapeutic hypothermia, which may reflect a lack of cerebral vascular adaptation in newborns with more severe brain injury. PMID:24582011
Jimenez-Juan, Laura; Karur, Gauri R; Connelly, Kim A; Deva, Djeven; Yan, Raymond T; Wald, Rachel M; Singh, Sheldon; Leung, General; Oikonomou, Anastasia; Dorian, Paul; Angaran, Paul; Yan, Andrew T
2017-04-01
Indications for the primary prevention of sudden death using an implantable cardioverter defibrillator (ICD) are based predominantly on left ventricular ejection fraction (LVEF). However, right ventricular ejection fraction (RVEF) is also a known prognostic factor in a variety of structural heart diseases that predispose to sudden cardiac death. We sought to investigate the relationship between right and left ventricular parameters (function and volume) measured by cardiovascular magnetic resonance (CMR) among a broad spectrum of patients considered for an ICD. In this retrospective, single tertiary-care center study, consecutive patients considered for ICD implantation who were referred for LVEF assessment by CMR were included. Right and left ventricular function and volumes were measured. In total, 102 patients (age 62±14 years; 23% women) had a mean LVEF of 28±11% and RVEF of 44±12%. The left ventricular and right ventricular end diastolic volume index was 140±42 mL/m 2 and 81±27 mL/m 2 , respectively. Eighty-six (84%) patients had a LVEF <35%, and 63 (62%) patients had right ventricular systolic dysfunction. Although there was a significant and moderate correlation between LVEF and RVEF ( r =0.40, p <0.001), 32 of 86 patients (37%) with LVEF <35% had preserved RVEF, while 9 of 16 patients (56%) with LVEF ≥35% had right ventricular systolic dysfunction (Kappa=0.041). Among patients being considered for an ICD, there is a positive but moderate correlation between LVEF and RVEF. A considerable proportion of patients who qualify for an ICD based on low LVEF have preserved RVEF, and vice versa.
Titin isoform switching is a major cardiac adaptive response in hibernating grizzly bears.
Nelson, O Lynne; Robbins, Charles T; Wu, Yiming; Granzier, Henk
2008-07-01
The hibernation phenomenon captures biological as well as clinical interests to understand how organs adapt. Here we studied how hibernating grizzly bears (Ursus arctos horribilis) tolerate extremely low heart rates without developing cardiac chamber dilation. We evaluated cardiac filling function in unanesthetized grizzly bears by echocardiography during the active and hibernating period. Because both collagen and titin are involved in altering diastolic function, we investigated both in the myocardium of active and hibernating grizzly bears. Heart rates were reduced from 84 beats/min in active bears to 19 beats/min in hibernating bears. Diastolic volume, stroke volume, and left ventricular ejection fraction were not different. However, left ventricular muscle mass was significantly lower (300 +/- 12 compared with 402 +/- 14 g; P = 0.003) in the hibernating bears, and as a result the diastolic volume-to-left ventricular muscle mass ratio was significantly greater. Early ventricular filling deceleration times (106.4 +/- 14 compared with 143.2 +/- 20 ms; P = 0.002) were shorter during hibernation, suggesting increased ventricular stiffness. Restrictive pulmonary venous flow patterns supported this conclusion. Collagen type I and III comparisons did not reveal differences between the two groups of bears. In contrast, the expression of titin was altered by a significant upregulation of the stiffer N2B isoform at the expense of the more compliant N2BA isoform. The mean ratio of N2BA to N2B titin was 0.73 +/- 0.07 in the active bears and decreased to 0.42 +/- 0.03 (P = 0.006) in the hibernating bears. The upregulation of stiff N2B cardiac titin is a likely explanation for the increased ventricular stiffness that was revealed by echocardiography, and we propose that it plays a role in preventing chamber dilation in hibernating grizzly bears. Thus our work identified changes in the alternative splicing of cardiac titin as a major adaptive response in hibernating grizzly bears.
EVAHEART: an implantable centrifugal blood pump for long-term circulatory support.
Yamazaki, Kenji; Kihara, Shinichiro; Akimoto, Takehide; Tagusari, Osamu; Kawai, Akihiko; Umezu, Mitsuo; Tomioka, Jun; Kormos, Robert L; Griffith, Bartley P; Kurosawa, Hiromi
2002-11-01
We developed "EVAHEART": a compact centrifugal blood pump system as an implantable left ventricular assist device for long-term circulatory support. The 55 x 64 mm pump is made from pure titanium, and weighs 370 g. The entire blood-contacting surface is covered with an anti-thrombogenic coating of diamond like carbon (DLC) or 2-methacryloyloxyethyl phosphorylcholine (MPC) to improve blood compatibility. Flows exceeding 12 L/min against 100 mmHg pressure at 2600 rpm was measured. A low-temperature mechanical seal with recirculating cooling system is used to seal the shaft. EVAHEART demonstrated an acceptably low hemolysis rate with normalized index of hemolysis of 0.005 +/- 0.002 g/100L. We evaluated the pump in long-term in-vivo experiments with seven calves. Via left thoracotomy, we conducted left ventricular apex-descending aorta bypass, placing the pump in the left thoracic cavity. Pump flow rates was maintained at 5-9 L/min, pump power consumption remained stable at 9-10 W in all cases, plasma free Hb levels were less than 15 mg/dl, and the seal system showed good seal capability throughout the experiments. The calves were sacrificed on schedule on postoperative day 200, 222, 142, 90, 151, 155, and 133. No thrombi formed on the blood contacting surface with either the DLC or MPC coating, and no major organ thromboembolisms occurred except for a few small renal infarcts. EVAHEART centrifugal blood pump demonstrated excellent performance in long-term in-vivo experiments.
Cardiac transplantation after bridged therapy with continuous flow left ventricular assist devices.
Deo, Salil V; Sung, Kiick; Daly, Richard C; Shah, Ishan K; Altarabsheh, Salah E; Stulak, John M; Joyce, Lyle D; Boilson, Barry A; Kushwaha, Sudhir S; Park, Soon J
2014-03-01
Cardiac transplantation is an effective surgical therapy for end-stage heart failure. Patients (pts) may need to be bridged with a continuous flow left ventricular assist device (CF-LVAD) while on the transplant list as logistic factors like organ availability are unknown. Cardiac transplantation post-LVAD can be a surgically challenging procedure and outcome in these pts is perceived to be poorer based on experience with earlier generation pulsatile flow pumps. Data from a single institution comparing these pts with those undergoing direct transplantation in the present era of continuous flow device therapy are limited. Evaluate results of cardiac transplantation in pts bridged with a CF-LVAD (BTx) and compare outcomes with pts undergoing direct transplantation (Tx) in a single institution. From June 2007 till January 2012, 106 pts underwent cardiac transplantation. Among these, 37 (35%) pts (51±11 years; 85% male) were bridged with a CF-LVAD (BTx), while 70 (65%) comprised the Tx group (53±12 years; 72% males). The median duration of LVAD support was 227 (153,327) days. During the period of LVAD support, 10/37 (27%) pts were upgraded to status 1A and all were successfully transplanted. Median hospital stay in the BTx (14 days) was slightly longer than the Tx group (12 days) but not statistically significant (p=0.21). In-hospital mortality in the BTx (5%) and Tx (1%) were comparable (p=0.25). Estimated late survival in the BTx cohort was 94±7, 90±10 and 83±16% at the end of one, two and three years, respectively which was comparable to 97±4%, 93±6% and 89±9% for the Tx group (p=0.50). Cardiac transplantation after LVAD implant can be performed with excellent results. Patients can be supported on the left ventricular assist device even for periods close to a year with good outcome after cardiac transplantation. Copyright © 2013 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.
Nikolaidis, Lazaros A; Poornima, Indu; Parikh, Pratik; Magovern, Megan; Shen, You-Tang; Shannon, Richard P
2006-05-02
Given that adverse effects of chronic sympathetic activation are mediated by all three adrenergic receptor subtypes (beta1, beta2, alpha1), we examined the effects of standard doses of carvedilol and metoprolol succinate (metoprolol controlled release/extended release [CR/XL]) on hemodynamics, myocardial metabolism, and regional organ perfusion. Both beta1 selective and combined adrenergic blockade reduce morbidity and mortality in heart failure. Whether there are advantages of one class over the other remains controversial, even in the wake of the Carvedilol Or Metoprolol European Trial (COMET). Similarly, the mechanistic basis for the relative differences is incompletely understood. Thirty-three conscious, chronically instrumented dogs with pacing-induced (240 min(-1) for 4 weeks) dilated cardiomyopathy (DCM) were randomized to carvedilol (25 mg twice daily, Coreg, Glaxo Smith Kline, Research Triangle, North Carolina) or metoprolol succinate (100 mg qd, Toprol XL, Astra Zeneca, Wilmington, Delaware). Left ventricular and systemic hemodynamics, myocardial substrate uptake, and norepinephrine spillover were measured before and after three days of treatment. Regional (renal, hepatic, skeletal muscle) blood flows were measured using neutron-activated microspheres. Both agents had comparable heart rate effects. However, carvedilol-treated dogs showed significantly greater increases in stroke volume and cardiac output and decreases in left ventricular end-diastolic pressure and systemic vascular resistance. Carvedilol increased renal, hepatic, and skeletal muscle blood flow. Carvedilol increased myocardial glucose uptake and suppressed norepinephrine and glucagon. Carvedilol antagonized the response to exogenous norepinephrine to a greater extent than metoprolol CR/XL. At doses inducing comparable heart rate reductions, short-term treatment with carvedilol had superior hemodynamic and metabolic effects compared with metoprolol CR/XL. These data suggest important advantages of blocking all three adrenergic receptor subtypes in DCM.
Congenital left ventricular aneurysms and diverticula: an entity in search of an identity
Ohlow, Marc-Alexander
2017-01-01
Congenital left ventricular aneurysm or diverticulum are rare cardiac malformations described in 809 cases since the first description in 1816, being associated with other cardiac, vascular or thoraco-abdominal abnormalities in about 70%. It appears to be a developmental anomaly, starting in the 4th embryonic week. In an experimental study, targeted knockdown of cardiac troponin T in the chick was performed at day 3, after the heart tube has formed. Morpholino treatment of gene TNNT2 at this stage led to the development of left ventricular diverticula (LVD) in the primitive left ventricular wall. Diagnosis of left ventricular aneurysms (LVA)/LVD can be made after exclusion of coronary artery disease, local or systemic inflammation or traumatic causes as well as cardiomyopathies. Clinically, most of LVA and LVD are asymptomatic or may cause systemic embolization, congestive heart failure, valvular regurgitation, ventricular wall rupture, ventricular tachycardia or sudden cardiac death. Diagnosis is established by imaging studies (echocardiography, magnetic resonance imaging or left ventricular angiography) visualizing the structural changes and accompanying abnormalities. Mode of treatment has to be individually tailored and depends on clinical presentation, accompanying abnormalities and possible complications, options include surgical resection (especially in symptomatic patients), anticoagulation after systemic embolization, radiofrequency ablation or implantation of an implantable cardioverter defibrillator (ICD) in case of symptomatic ventricular tachycardias, and occasionally combined with class I- or III-antiarrhythmic drugs. Cardiac death occurs usually in childhood, is significantly more frequent in LVA patients and caused by congestive heart failure in most of the cases, whereas patients diagnosed with LVD died more frequently from rupture of the LVD. PMID:29581714
Congenital left ventricular aneurysms and diverticula: an entity in search of an identity.
Ohlow, Marc-Alexander
2017-12-01
Congenital left ventricular aneurysm or diverticulum are rare cardiac malformations described in 809 cases since the first description in 1816, being associated with other cardiac, vascular or thoraco-abdominal abnormalities in about 70%. It appears to be a developmental anomaly, starting in the 4 th embryonic week. In an experimental study, targeted knockdown of cardiac troponin T in the chick was performed at day 3, after the heart tube has formed. Morpholino treatment of gene TNNT2 at this stage led to the development of left ventricular diverticula (LVD) in the primitive left ventricular wall. Diagnosis of left ventricular aneurysms (LVA)/LVD can be made after exclusion of coronary artery disease, local or systemic inflammation or traumatic causes as well as cardiomyopathies. Clinically, most of LVA and LVD are asymptomatic or may cause systemic embolization, congestive heart failure, valvular regurgitation, ventricular wall rupture, ventricular tachycardia or sudden cardiac death. Diagnosis is established by imaging studies (echocardiography, magnetic resonance imaging or left ventricular angiography) visualizing the structural changes and accompanying abnormalities. Mode of treatment has to be individually tailored and depends on clinical presentation, accompanying abnormalities and possible complications, options include surgical resection (especially in symptomatic patients), anticoagulation after systemic embolization, radiofrequency ablation or implantation of an implantable cardioverter defibrillator (ICD) in case of symptomatic ventricular tachycardias, and occasionally combined with class I- or III-antiarrhythmic drugs. Cardiac death occurs usually in childhood, is significantly more frequent in LVA patients and caused by congestive heart failure in most of the cases, whereas patients diagnosed with LVD died more frequently from rupture of the LVD.
Surgical approach to left ventricular inflow obstruction due to dilated coronary sinus.
Vargas, Florentino J; Rozenbaum, Jorge; Lopez, Ricardo; Granja, Miguel; De Dios, Ana; Zarlenga, Beatriz; Flores, Enrique; Fischman, Enrique; Kreutzer, Eduardo
2006-07-01
Left superior vena cava draining to a dilated coronary sinus can cause left ventricular inflow obstruction. Our purpose is to report 4 severely ill patients with this malformation who were operated upon and in whom repair was accomplished using an original surgical approach. An operative procedure was designed, which included complete resection of the wall of the coronary sinus along its entire extension in the left atrium; division of the left superior vena cava; and establishment of the left superior vena cava-right atrial continuity by a wide left superior vena cava-right atrial appendage anastomosis. The series included 1 patient with interrupted inferior vena cava-hemiazygous continuation to left superior vena cava. There were no deaths. Absence of residual left ventricular inflow obstruction was demonstrated at follow-up in all cases, together with an unobstructed left superior vena cava-right atrial appendage-right atrial connection. A predictable relief of the left ventricular inflow obstruction, together with preservation of an adequate drainage for the systemic venous return, were both achieved with this repair.
A computer model of the pediatric circulatory system for testing pediatric assist devices.
Giridharan, Guruprasad A; Koenig, Steven C; Mitchell, Michael; Gartner, Mark; Pantalos, George M
2007-01-01
Lumped parameter computer models of the pediatric circulatory systems for 1- and 4-year-olds were developed to predict hemodynamic responses to mechanical circulatory support devices. Model parameters, including resistance, compliance and volume, were adjusted to match hemodynamic pressure and flow waveforms, pressure-volume loops, percent systole, and heart rate of pediatric patients (n = 6) with normal ventricles. Left ventricular failure was modeled by adjusting the time-varying compliance curve of the left heart to produce aortic pressures and cardiac outputs consistent with those observed clinically. Models of pediatric continuous flow (CF) and pulsatile flow (PF) ventricular assist devices (VAD) and intraaortic balloon pump (IABP) were developed and integrated into the heart failure pediatric circulatory system models. Computer simulations were conducted to predict acute hemodynamic responses to PF and CF VAD operating at 50%, 75% and 100% support and 2.5 and 5 ml IABP operating at 1:1 and 1:2 support modes. The computer model of the pediatric circulation matched the human pediatric hemodynamic waveform morphology to within 90% and cardiac function parameters with 95% accuracy. The computer model predicted PF VAD and IABP restore aortic pressure pulsatility and variation in end-systolic and end-diastolic volume, but diminish with increasing CF VAD support.
Effect of varying heart rate on intra-ventricular filling fluid dynamics
NASA Astrophysics Data System (ADS)
Santhanakrishnan, Arvind; Okafor, Ikechukwu; Angirish, Yagna; Yoganathan, Ajit
2013-11-01
Impaired exercise tolerance is used to delineate asymptomatic patients during the clinical diagnosis of diastolic left heart failure. Examining the effects of varying heart rate on intra-ventricular filling can provide a physical understanding of the specific flow characteristics that are impacted during exercise. In this study, diastolic filling was investigated with an anatomical left ventricle (LV) physical model under normal heart rate of 70 bpm, and varying exercise conditions of 100 bpm and 120 bpm. The LV model was incorporated into a flow loop and tuned for physiological inflow rates and outflow pressures. 2D PIV measurements were conducted along 3 parallel longitudinal planes. The systemic pressure was maintained the same across all test conditions. The E/A ratio was maintained within 1.0-1.2 across all heart rates. The strength of the mitral vortex ring formed during E-wave, as well as the peak incoming jet velocity, decreased with increasing heart rate. During peak flow of the A-wave, the vortex ring propagated farther into the LV for 120 bpm as compared to 70 bpm. The results point to the heightened role of the atrial kick for optimal LV filling during exercise conditions. This study was funded by a grant from the National Heart, Lung and Blood Institute (RO1HL70262).
Cortigiani, Lauro; Huqi, Alda; Ciampi, Quirino; Bombardini, Tonino; Bovenzi, Francesco; Picano, Eugenio
2018-06-01
Coronary flow velocity reserve (CFVR) and left ventricular contractile reserve (LVCR) have demonstrated prognostic importance in patients with diabetes. The aim of this study was to investigate the prognostic contribution of combined evaluation of CFVR and LVCR in patients with diabetes with nonischemic stress echocardiography. Three hundred seventy-five patients with diabetes (mean age, 68 ± 9 years) with nonischemic dipyridamole stress echocardiography underwent assessment of CFVR of the left anterior descending coronary artery (prospectively) and LVCR with left ventricular force (retrospectively) in a multicenter study. On receiver operating characteristic analysis, LVCR ≤ 1.1 was the best prognostic predictor and was considered an abnormal value. CFVR was abnormal (≤2) in 139 patients (37%), LVCR in 156 (42%), neither in 157 (42%), and both in 77 (21%). During a median follow-up period of 16 months, 86 major adverse cardiac events occurred: 16 deaths, 13 myocardial infarctions, and 57 revascularizations. Multivariate prognostic indicators were CFVR ≤ 2 (P < .0001), age (P = .03), and LVCR ≤ 1.1 (P = .04). The 3-year rate of major adverse cardiac events was 63% in patients with both abnormal CFVR and LVCR, 42% in those with abnormal CFVR only, 19% in those with abnormal LVCR only, and 10% in patients with both normal CFVR and LVCR. The 3-year hard event rate was 3% in patients with both normal CFVR and LVCR, fivefold higher in patients with abnormal CFVR or LVCR only, and ninefold higher in patients with both abnormal CFVR and LVCR. Patients with diabetes with nonischemic dipyridamole stress echocardiography may still have significant risk in presence of abnormal CFVR and/or LVCR, which assess the underlying, largely unrelated, microvascular and myocardial components of coronary circulation. Copyright © 2017 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
[The repercussions of pulmonary congestion on ventilatory volumes, capacities and flows].
Carmo, M M; Ferreira, T; Lousada, N; Bárbara, C; Neves, P R; Correia, J M; Rendas, A B
1994-10-01
To evaluate the effects of pulmonary congestion on pulmonary function. Prospective study performed in patients with left ventricular failure or mitral stenosis. Forty-eight hospitalized patients were included suffering from pulmonary congestion either from left ventricular failure or mitral stenosis. While in hospital all patients were submitted to right heart catheterization by the Swan-Ganz method and also to an echocardiographic examination. Within 48 hours after the patients were submitted to the following lung function studies: lung volumes and capacities by the multi-breath helium dilution method and airway flows by pneumotachography. Respiratory symptoms were evaluated by the Medical Research Council Questionnaire and the functional class classified according to the NYHA. Correlations were made between the functional and clinical data. Regarding the cardiac evaluation patients presented with a mean pulmonary wedge pressure of 19.9 +/- 8.6 mmHg, a cardiac index of 2.5 +/- 0.8 l/min/m2, an end diastolic dimension of the left ventricle of 65.9 +/- 10.1 mm, and end systolic dimension of 51.2 +/- 12.2 mm, with a shortening fraction of 21.8 +/- 9.5%. The pulmonary evaluation showed a restrictive syndrome with a reduction in the mean values of the following parameters: total pulmonary capacity 71 +/- 14.4% of the predicted value (pv), forced vital capacity (FVC) 69.8 +/- 20.5% pv, and forced expiratory volume (FEV1) of 64 +/- 21.8% vp. The index FEV1/FVC was within the normal value of 72.7 +/- 9.7%. These lung function results did not correlate significantly with either the clinical, the hemodynamic or echocardiographic findings. In these group of patients pulmonary congestion led to the development of a restrictive syndrome which failed to correlate in severity with the duration of the disease, the pulmonary wedge pressure and the left ventricular function.
[Surgical treatment of congenital obstruction of the left ventricular outflow tract].
Biocina, B; Sutlić, Z; Husedinović, I; Letica, D; Sokolić, J
1993-01-01
This report presents the classification and all types of left ventricular outflow tract obstructions. The possibilities of operative therapies are surveyed as well. Results of surgical treatment in 34 patients with obstruction to left ventricular outflow are shown. The majority of patients underwent operation under extracorporeal circulation (84.4%), while the rest were operated by means of the inflow occlusion technique (14.7%). The obtained results were compared with those from the literature. The importance of echocardiographic evaluation of location of the left ventricular outflow tract obstruction and the appropriate choice of a surgical technique according to the patient's age are emphasized.
Heat Generation in Axial and Centrifugal Flow Left Ventricular Assist Devices.
Yost, Gardner; Joseph, Christine Rachel; Royston, Thomas; Tatooles, Antone; Bhat, Geetha
Despite increasing use of left ventricular assist devices (LVADs) as a surgical treatment for advanced heart failure in an era of improved outcomes with LVAD support, the mechanical interactions between these pumps and the cardiovascular system are not completely understood. We utilized an in vitro mock circulatory loop to analyze the heat production incurred by operation of an axial flow and centrifugal flow LVAD. A HeartMate II and a HeartWare HVAD were connected to an abbreviated flow loop and were implanted in a viscoelastic gel. Temperature was measured at the surface of each LVAD. Device speed and fluid viscosity were altered and, in the HeartMate II, as artificial thrombi were attached to the inflow stator, impeller, and outflow stator. The surface temperatures of both LVADs increased in all trials and reached a plateau within 80 minutes of flow initiation. Rate of heat generation and maximum system temperature were greater when speed was increased, when viscosity was increased, and when artificial thrombi were attached to the HeartMate II impeller. Normal operation of these two widely utilized LVADs results in appreciable heat generation in vitro. Increased pump loading resulted in more rapid heat generation, which was particularly severe when a large thrombus was attached to the impeller of the HeartMate II. While heat accumulation in vivo is likely minimized by greater dissipation in the blood and soft tissues, focal temperature gains with the pump housing of these two devices during long-term operation may have negative hematological consequences.
[Geographical distribution of left ventricular Tei index based on principal component analysis].
Xu, Jinhui; Ge, Miao; He, Jinwei; Xue, Ranyin; Yang, Shaofang; Jiang, Jilin
2014-11-01
To provide a scientific standard of left ventricular Tei index for healthy people from various region of China, and to lay a reliable foundation for the evaluation of left ventricular diastolic and systolic function. The correlation and principal component analysis were used to explore the left ventricular Tei index, which based on the data of 3 562 samples from 50 regions of China by means of literature retrieval. Th e nine geographical factors were longitude(X₁), latitude(X₂), altitude(X₃), annual sunshine hours (X₄), the annual average temperature (X₅), annual average relative humidity (X₆), annual precipitation (X₇), annual temperature range (X₈) and annual average wind speed (X₉). ArcGIS soft ware was applied to calculate the spatial distribution regularities of left ventricular Tei index. There is a significant correlation between the healthy people's left ventricular Tei index and geographical factors, and the correlation coefficients were -0.107 (r₁), -0.301 (r₂), -0.029 (r₃), -0.277 (r₄), -0.256(r₅), -0.289(r₆), -0.320(r₇), -0.310 (r₈) and -0.117 (r₉), respectively. A linear equation between the Tei index and the geographical factor was obtained by regression analysis based on the three extracting principal components. The geographical distribution tendency chart for healthy people's left Tei index was fitted out by the ArcGIS spatial interpolation analysis. The geographical distribution for left ventricular Tei index in China follows certain pattern. The reference value in North is higher than that in South, while the value in East is higher than that in West.
Tamez, Daniel; LaRose, Jeffrey A.; Shambaugh, Charles; Chorpenning, Katherine; Soucy, Kevin G; Sobieski, Michael A; Sherwood, Leslie; Giridharan, Guruprasad A; Monreal, Gretel; Koenig, Steven C; Slaughter, Mark S
2014-01-01
Implantation of ventricular assist devices (VADs) for treatment of end-stage heart failure (HF) falls decidedly short of clinical demand, which exceeds 100,000 HF patients per year. VAD implantation often requires major surgical intervention with associated risk of adverse events and long recovery periods. To address these limitations, HeartWare, Inc. (Miami Lakes, FL) has developed a platform of miniature ventricular devices with progressively reduced surgical invasiveness and innovative patient peripherals. One surgical implant concept is a transapical version of the miniaturized left ventricular assist device (MVAD). The HeartWare MVAD Pump® is a small, continuous flow, full-support device that has a displacement volume of 22mL. A new cannula configuration has been developed for transapical implantation, where the outflow cannula is positioned across the aortic valve. The two primary objectives for this feasibility study were to evaluate anatomic fit and surgical approach and efficacy of the transapical MVAD configuration. Anatomic fit and surgical approach were demonstrated using human cadavers (n=4). Efficacy was demonstrated in acute (n =2) and chronic (n = 1) bovine model experiments and assessed by improvements in hemodynamics, biocompatibility, flow dynamics, and histopathology. Potential advantages of the MVAD Pump include flow support in the same direction as the native ventricle, elimination of cardiopulmonary bypass, and minimally-invasive implantation. PMID:24399057
El Saiedi, Sonia A; Mira, Marwa F; Sharaf, Sahar A; Al Musaddar, Maysoun M; El Kaffas, Rania M H; AbdelMassih, Antoine F; Barsoum, Ihab H Y
2018-01-01
Obesity increases the risk for various cardiovascular problems. Increase in body mass index is often an independent risk factor for the development of elevated blood pressure and clustering of various cardiovascular risk factors. To determine early markers of left ventricular affection in obese patients before the appearance of left ventricular hypertrophy. In this cross-sectional study, we evaluated 42 obese patients and 30 healthy controls. Their ages ranged from 6 to 19 years. Studied children were subjected to anthropometric, lipid profile, and serum Troponin I level measurements. Echocardiographic evaluation performed to assess the left ventricle included left ventricular dimension measurement using motion-mode echocardiography, based on which patients with left ventricular hypertrophy (10 patients) were eliminated, as well as conventional and tissue Doppler imaging. Tissue Doppler findings in the study groups showed that the ratio of transmitral early diastolic filling velocity to septal peak early diastolic myocardial velocity (E/e') was significantly higher in cases compared with controls [6.9±1.4 versus 9.0±1.6, p (Pearson's coefficient)=0.001, respectively]. The level of cardiac troponin I was significantly higher in cases compared with controls [0.14±0.39 ng/ml versus 0.01±0.01 ng/ml, p (Pearson's coefficient)=0.047, respectively] and there was a significant correlation between troponin I and transmitral early diastolic filling velocity to septal peak early diastolic myocardial velocity ratio (E/e') [R (correlation coefficient)=0.6]. Tissue Doppler Imaging and Troponin I evaluation proved useful tools to detect early affection of the left ventricle in obese patients even in the absence of left ventricular hypertrophy.
Richardson, Travis D; Hale, Leslie; Arteaga, Christopher; Xu, Meng; Keebler, Mary; Schlendorf, Kelly; Danter, Matthew; Shah, Ashish; Lindenfeld, JoAnn; Ellis, Christopher R
2018-02-23
Ventricular arrhythmias are common in patients with left ventricular assist devices (LVADs) but are often hemodynamically tolerated. Optimal implantable cardioverter defibrillator (ICD) tachy-programming strategies in patients with LVAD have not been determined. We sought to determine if an ultra-conservative ICD programming strategy in patients with LVAD affects ICD shocks. Adult patients with an existing ICD undergoing continuous flow LVAD implantation were randomized to standard ICD programming by their treating physician or an ultra-conservative ICD programming strategy utilizing maximal allowable intervals to detection in the ventricular fibrillation and ventricular tachycardia zones with use of ATP. Patients with cardiac resynchronization therapy (CRT) devices were also randomized to CRT ON or OFF. Patients were followed a minimum of 6 months. The primary outcome was time to first ICD shock. Among the 83 patients studied, we found no statistically significant difference in time to first ICD shock or total ICD shocks between groups. In the ultra-conservative group 16% of patients experienced at least one shock compared with 21% in the control group ( P =0.66). There was no difference in mortality, arrhythmic hospitalization, or hospitalization for heart failure. In the 41 patients with CRT ICDs fewer shocks were observed with CRT-ON but this was not statistically significant: 10% of patients with CRT-ON (n=21) versus 38% with CRT-OFF (n=20) received shocks ( P =0.08). An ultra-conservative programming strategy did not reduce ICD shocks. Programming restrictions on ventricular tachycardia and ventricular fibrillation zone therapy should be reconsidered for the LVAD population. The role of CRT in patients with LVAD warrants further investigation. URL: https://www.clinicaltrials.gov. Unique identifier: NCT01977703. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Diastolic blood pressure-estimated left ventricular dp/dt.
Yilmaz, Hüseyin; Minareci, Kenan; Kabukçu, Mehmet; Sancaktar, Oktay
2002-02-01
Peak dp/dt is one of the best isovolumic phase indexes of the myocardial contractile state requiring invasive procedures or presence of mitral regurgitation severe enough to measure in clinical practice by Doppler echocardiography. In this study, we sought the correlation between two noninvasive methods of measurements for left ventricular dp/dt-diastolic blood pressure- (DBP) estimated and continuous-wave Doppler-derived dp/dt-min electrocardiographic/echocardiographic study to emphasize the clinical feasibility of the DBP-estimated method. Thirty-six randomized patients (27 male, 9 female; 58 +/- 8 years) with mild mitral regurgitation were enrolled in this study. DBP-estimated dp/dt was calculated from DBP minus the left ventricular end-diastolic pressure (LVEDP) over the isovolumetric contraction time (IVCT). LVEDP was assumed to be 10 mmHg for all patients. Doppler-determined left ventricular dp/dt was derived from the continuous-wave Doppler spectrum of mitral regurgitation jet by dividing the magnitude of the left ventricular atrial pressure gradient rise between 1 mm/sec-3 mm/sec of mitral regurgitant velocity signal by the time taken for this change. Left ventricular dp/dt by Doppler was 1122 +/- 303 mmHg/sec and blood pressure-estimated dp/dt was 1063 +/- 294 mmHg/sec. There was a high correlation (r = 0.97, P < 0.001) of dp/dt between the two techniques. DBP and IVCT can generate left ventricular dp/dt without invasive procedures, even in the absence of mitral regurgitation in clinical practice.
Aldosterone is associated with left ventricular hypertrophy in hemodialysis patients.
Feniman De Stefano, Greicy Mara Mengue; Zanati-Basan, Silméia Garcia; De Stefano, Laercio Martins; Silva, Viviana Rugolo Oliveira E; Xavier, Patrícia Santi; Barretti, Pasqual; da Silva Franco, Roberto Jorge; Caramori, Jacqueline Costa Teixeira; Martin, Luis Cuadrado
2016-10-01
Patients with chronic kidney disease present a higher degree of left ventricular hypertrophy than expected for hypertension levels. In chronic kidney disease the plot between the quotient extracellular water/total body water and aldosterone is shifted up and to the right. There are few studies that verified the role of aldosterone in cardiac remodeling in this set of patients. The aim of this study was to evaluate the relationship between serum aldosterone and left ventricular mass index in patients with chronic kidney disease on hemodialysis. The patients were submitted to clinical and laboratory evaluation, bioelectrical impedance, echocardiography and ambulatory blood pressure monitoring. The 27 patients included were divided into two groups according to aldosterone level and compared with each other. The group of patients with higher aldosterone levels had higher left ventricular mass index. These groups were heterogeneous with regard to ambulatory systolic blood pressure, body mass index, and aldosterone levels and homogeneous with regard to the quotient extracellular water/total body water, renin-angiotensin-aldosterone system blockers, beta blocker use and other clinical characteristics. The association between aldosterone levels and left ventricular mass index was adjusted to confounding variables by a multiple linear regression analysis in which aldosterone was independently associated with left ventricular mass index. The data presented are consistent with a pathogenic role of aldosterone in left ventricular hypertrophy in patients with chronic kidney dialysis in dialysis patients. ClinicalTrials.gov identifier: NCT01128101. © The Author(s), 2016.
Ochi, H; Ikuma, I; Toda, H; Shimada, T; Morioka, S; Moriyama, K
1989-12-01
In order to determine whether isovolumic relaxation period (IRP) reflects left ventricular relaxation under different afterload conditions, 17 anesthetized, open chest dogs were studied, and the left ventricular pressure decay time constant (T) was calculated. In 12 dogs, angiotensin II and nitroprusside were administered, with the heart rate constant at 90 beats/min. Multiple linear regression analysis showed that the aortic dicrotic notch pressure (AoDNP) and T were major determinants of IRP, while left ventricular end-diastolic pressure was a minor determinant. Multiple linear regression analysis, correlating T with IRP and AoDNP, did not further improve the correlation coefficient compared with that between T and IRP. We concluded that correction of the IRP by AoDNP is not necessary to predict T from additional multiple linear regression. The effects of ascending aortic constriction or angiotensin II on IRP were examined in five dogs, after pretreatment with propranolol. Aortic constriction caused a significant decrease in IRP and T, while angiotensin II produced a significant increase in IRP and T. IRP was affected by the change of afterload. However, the IRP and T values were always altered in the same direction. These results demonstrate that IRP is substituted for T and it reflects left ventricular relaxation even in different afterload conditions. We conclude that IRP is a simple parameter easily used to evaluate left ventricular relaxation in clinical situations.
Left ventricular function abnormalities as a manifestation of silent myocardial ischemia.
Lambert, C R; Conti, C R; Pepine, C J
1986-11-01
A large body of evidence exists indicating that left ventricular dysfunction is a common occurrence in patients with severe coronary artery disease and represents silent or asymptomatic myocardial ischemia. Such dysfunction probably occurs early in the time course of every ischemic episode in patients with coronary artery disease whether symptoms are eventually manifested or not. The pathophysiology of silent versus symptomatic left ventricular dysfunction due to ischemia appears to be identical. Silent ischemia-related left ventricular dysfunction can be documented during spontaneous or stress-induced perturbations in the myocardial oxygen supply/demand ratio. It also may be detected by nitroglycerin-induced improvement in ventricular function or by salutary changes in wall motion following revascularization. Silent left ventricular dysfunction is a very early occurrence during ischemia and precedes electrocardiographic abnormalities. In this light, its existence should always be kept in mind when dealing with patients with ischemic heart disease. It can be hypothesized that because silent ischemia appears to be identical to ischemia with symptoms in a pathophysiologic sense, prognosis and treatment in both cases should be the same.
Hua, Yan; Xie, Manying; Yin, Jiabao; Wang, Yu; Gan, Ling; Sang, Ming; Sun, Xiaodong; Li, Mingyang; Liu, Shanjun; Xu, Jinzhi
2018-05-01
This report aims to evaluate the effect of atorvastatin (Ator) on left ventricular systolic function in myocardial infarction (MI) rats. Forty healthy adult Sprague-Dawley rats were randomly divided into four groups: Ator group, MI group, sham-operation group and normal group. The left anterior descending coronary arteries were ligated to establish the MI model; after modeling, the Ator group was treated with Ator for 4 consecutive weeks. The echocardiographic detection was performed; the left ventricular myocardial systolic peak velocities, strain and strain rates were analyzed using the 2D-STI technique. After 4 weeks, myocardial tissues were taken from all rats and received the pathological examination. Left ventricular end-diastolic diameter (LVEDD) and left ventricular end-systolic diameter (LVESD) in Ator group and MI group were increased after operation, but left ventricular ejection fraction (LVEF) and left ventricular fractional shortening (LVFS) were decreased; myocardial function were decreased significantly (p<0.05). After Ator treatment, myocardial function at the 3rd and 4th week after operation increased significantly (p<0.05). After Ator treatment, LVEDD and LVESD decreased while LVEF and LVFS increased in Ator group at the 3rd and 4th week after operation compared with MI group (p<0.05). At the 4th week after operation, LVEDD and LVESD in Ator group were decreased compared with those at the 1st and 2nd week after operation, but LVEF and LVFS were increased compared with those at the 1st, 2nd and 3rd week after operation (p<0.05). Pathological examination showed that necrosis and fibrosis of myocardial cells and inflammatory reaction were obvious in MI group. The inflammatory reaction of myocardial cells and myocardial fibrosis were lighter in Ator group. Ator can effectively improve the left ventricular systolic function in MI rats, which could be related to the reduction of response to inflammation and fibrosis.
Succi, José Ernesto; Gerola, Luis Roberto; Succi, Guilherme de Menezes; Kim, Hyong Chun; Paredes, Jorge Edwin Morocho; Bufollo, Enio
2012-01-01
To evaluate intraoperative graft patency and identify grafts under risk of early occlusion. Fifty four patients were submitted to coronary artery bypass surgery and the graft flow was assessed by the Flowmeter (Medtronic Medistim), which utilizes the TTFM method. Three patients had left main disease and 48 had normal or mildly reduced left ventricular function. In hospital mortality was 3.7% (two patients), one for mesenteric thrombosis and one due to cardiogenic chock. Seventeen patients (34%) were submitted to off pump CABG. Arterial Graft flow measures ranged from 8 to 106 ml/min (average 31.14 ml/min), and venous grafts flow ranged from 9 to 149 ml/min (average 50.42 ml/min). Flowmeter use represents higher safety both for patients and surgeons. Even under legal aspects, the documentation provided by the device can avoid future questionings.
Cardiac structure and function in relation to cardiovascular risk factors in Chinese
2012-01-01
Background Cardiac structure and function are well-studied in Western countries. However, epidemiological data is still scarce in China. Methods Our study was conducted in the framework of cardiovascular health examinations for the current and retired employees of a factory and their family members. According to the American Society of Echocardiography recommendations, we performed echocardiography to evaluate cardiac structure and function, including left atrial volume, left ventricular hypertrophy and diastolic dysfunction. Results The 843 participants (43.0 years) included 288 (34.2%) women, and 191 (22.7%) hypertensive patients, of whom 82 (42.9%) took antihypertensive drugs. The prevalence of left atrial enlargement, left ventricular hypertrophy and concentric remodeling was 2.4%, 5.0% and 12.7%, respectively. The prevalence of mild and moderate-to-severe left ventricular diastolic dysfunction was 14.2% and 3.3%, respectively. The prevalence of these cardiac abnormalities significantly (P ≤ 0.002) increased with age, except for the moderate-to-severe left ventricular diastolic dysfunction. After adjustment for age, gender, body height and body weight, left atrial enlargement was associated with plasma glucose (P = 0.009), and left ventricular hypertrophy and diastolic dysfunction were significantly associated with systolic and diastolic blood pressure (P ≤ 0.03), respectively. Conclusions The prevalence of cardiac structural and functional abnormalities increased with age in this Chinese population. Current drinking and plasma glucose had an impact on left atrial enlargement, whereas systolic and diastolic blood pressures were major correlates for left ventricular hypertrophy and diastolic dysfunction, respectively. PMID:23035836
Cansu, Güven Barış; Yılmaz, Nusret; Yanıkoğlu, Atakan; Özdem, Sebahat; Yıldırım, Aytül Belgi; Süleymanlar, Gültekin; Altunbaş, Hasan Ali
2017-05-01
Early diagnosis and treatment of cardiovascular diseases, the most frequent cause of morbidity and mortality in acromegaly, may be an efficient approach to extending the lifespan of affected patients. Therefore, it is crucial to determine any cardiovascular diseases in the subclinical period. The study objectives were to determine markers of subclinical atherosclerosis and asses heart structure and function. This was a cross-sectional, single-center study of 53 patients with acromegaly and 22 age- and sex-matched healthy individuals. Carotid intima-media thickness (CIMT), pulse-wave velocity (PWV), and echocardiographic data were compared between these groups. CIMT and PWV were higher in the acromegaly group than in the healthy group (P = .008 and P = .002, respectively). Echocardiography showed that left ventricular diastolic dysfunction was present in 11.3% of patients. Left ventricular mass index and left atrial volume index were higher in the patients (P = .016 and P<.001, respectively). No differences in the CIMT, PWV, or echocardiographic measurements were identified between the patients with biochemically controlled and uncontrolled acromegaly and the control group. Our results showed that subclinical atherosclerosis (i.e., CIMT and PWV markers) and heart structure and function were worse in patients with acromegaly than in healthy individuals. Because there were no differences in these parameters between patients with controlled and uncontrolled acromegaly, our results suggest that the structural and functional changes do not reverse with biochemical control. AA = active acromegaly BSA = body surface area CA = biochemically controlled acromegaly CH = concentric hypertrophy CIMT = carotid intima-media thickness DBP = diastolic blood pressure DM = diabetes mellitus ECHO = echocardiography EDV = enddiastolic volume EF = ejection fraction ESV = endsystolic volume GH = growth hormone HC = healthy control HL = hyperlipidemia HT = hypertension IGF-1 = insulin-like growth factor 1 LA = left atrial LAV = left atrial volume LAVI = left atrial volume index LV = left ventricular LVDD = left ventricular diastolic dysfunction LVEF = left ventricular ejection fraction LVH = left ventricular hypertrophy LVMI = left ventricular mass index PWV = pulse-wave velocity RWT = relative wall thickness.
Fischer, Quentin; Huisse, Marie-Geneviève; Voiriot, Guillaume; Caron, Claudine; Lepage, Laurent; Dilly, Marie-Pierre; Nataf, Patrick; Ajzenberg, Nadine; Kirsch, Matthias
2015-01-01
Bleeding originating in the gastrointestinal (GI) tract is one of the most common adverse events after left ventricular assist device (LVAD) implantation. In these patients, GI bleeding appears to be the consequence of altered hemostasis on the one hand and alterations of the GI microvasculature on the other. We report the case of a patient who suffered repeated, severe GI bleeding early after implantation of a HeartMate II continuous-flow LVAD. After failure of conventional treatment strategies, GI bleeding was controlled using repeated transfusions of a purified von Willebrand factor (VWF) concentrate, almost devoid of Factor VIII (Wilfactin, LFB). No episodes of pump thrombosis were noted. Subsequent to VWF transfusions, we observed a progressive normalization of circulating vascular endothelial growth factor levels. Our data raise the possibility that, in addition to its hemostatic properties, transfusions of VWF might have acted as an antiangiogenic factor. © 2014 AABB.
Aneurysmal coronary cameral fistula
Jamil, Gohar; Khan, Asad; Malik, Azhar; Qureshi, Anwer
2013-01-01
A 26-year-old asymptomatic man, being medically managed for ventricular septal defect since childhood, presented to the outpatient clinic for a second opinion. Clinically, he was well built with normal vital signs. Cardiac auscultation was significant for a diastolic murmur over the praecordium. An ECG showed non-specific ST changes, and a subsequent transthoracic echocardiography performed revealed diastolic flow from the left ventricular (LV) anteroseptal wall into the LV cavity. A diagnosis of coronary–cameral fistula was confirmed by a multidetector CT which showed a 2.5×2 cm aneurysmal left anterior descending artery fistula to the LV. In addition to starting aspirin, transcatheter closure with occlusion device was considered knowing the potential risk of thrombus formation in the aneurysm and subsequent systemic embolisation. The patient however refused any percutaneous or surgical intervention. He remains asymptomatic 1 year after returning to his home country. PMID:23737570
Alvarez, Alejandro; Borgia, Francesco; Guccione, Paolo
2010-02-01
We describe an infant of 8 months who presented with left ventricular dilation due to an extensive intralobar sequestration of the right lung. The pulmonary sequestration was associated with a patent arterial duct and a right aortic arch. Percutaneous closure of the anomalous aberrant artery feeding the sequestrated lung resulted in prompt regression of the left ventricular enlargement.
Left ventricular assist device and drug therapy for the reversal of heart failure.
Birks, Emma J; Tansley, Patrick D; Hardy, James; George, Robert S; Bowles, Christopher T; Burke, Margaret; Banner, Nicholas R; Khaghani, Asghar; Yacoub, Magdi H
2006-11-02
In patients with severe heart failure, prolonged unloading of the myocardium with the use of a left ventricular assist device has been reported to lead to myocardial recovery in small numbers of patients for varying periods of time. Increasing the frequency and durability of myocardial recovery could reduce or postpone the need for subsequent heart transplantation. We enrolled 15 patients with severe heart failure due to nonischemic cardiomyopathy and with no histologic evidence of active myocarditis. All had markedly reduced cardiac output and were receiving inotropes. The patients underwent implantation of left ventricular assist devices and were treated with lisinopril, carvedilol, spironolactone, and losartan to enhance reverse remodeling. Once regression of left ventricular enlargement had been achieved, the beta2-adrenergic-receptor agonist clenbuterol was administered to prevent myocardial atrophy. Eleven of the 15 patients had sufficient myocardial recovery to undergo explantation of the left ventricular assist device a mean (+/-SD) of 320+/-186 days after implantation of the device. One patient died of intractable arrhythmias 24 hours after explantation; another died of carcinoma of the lung 27 months after explantation. The cumulative rate of freedom from recurrent heart failure among the surviving patients was 100% and 88.9% 1 and 4 years after explantation, respectively. The quality of life as assessed by the Minnesota Living with Heart Failure Questionnaire score at 3 years was nearly normal. Fifty-nine months after explantation, the mean left ventricular ejection fraction was 64+/-12%, the mean left ventricular end-diastolic diameter was 59.4+/-12.1 mm, the mean left ventricular end-systolic diameter was 42.5+/-13.2 mm, and the mean maximal oxygen uptake with exercise was 26.3+/-6.0 ml per kilogram of body weight per minute. In this single-center study, we found that sustained reversal of severe heart failure secondary to nonischemic cardiomyopathy could be achieved in selected patients with the use of a left ventricular assist device and a specific pharmacologic regimen. Copyright 2006 Massachusetts Medical Society.
Effect of canagliflozin on left ventricular diastolic function in patients with type 2 diabetes.
Matsutani, Daisuke; Sakamoto, Masaya; Kayama, Yosuke; Takeda, Norihiko; Horiuchi, Ryuzo; Utsunomiya, Kazunori
2018-05-22
Type 2 diabetes mellitus (T2DM) greatly increases the risks of cardiovascular disease and heart failure. In particular, left ventricular diastolic dysfunction that develops from the early stages of T2DM is an important factor in the onset and exacerbation of heart failure. The effect of sodium-glucose cotransporter 2 inhibitors on left ventricular diastolic function has not been elucidated. We have performed the first prospective study on the effects of canagliflozin on left ventricular diastolic function in T2DM. This study was performed to evaluate the effects of additional treatment with canagliflozin for 3 months on left ventricular diastolic function in patients with T2DM. A total of 38 patients with T2DM were consecutively recruited for this study. Left ventricular diastolic function was assessed by echocardiography. The primary study outcome was a change in the septal E/e' as a parameter of left ventricular diastolic function. A total of 37 patients (25 males and 12 females) were included in the analysis. Mean age of participants was 64.2 ± 8.1 years (mean ± SD), mean duration of diabetes was 13.5 ± 8.1 years, and mean HbA1c was 7.9 ± 0.7%. Of the participants, 86.5% had hypertension, 100% had dyslipidemia, and 32.4% had cardiovascular disease. Canagliflozin significantly improved left ventricular diastolic function (septal E/e' ratio 13.7 ± 3.5-12.1 ± 2.8, p = 0.001). Furthermore, among the various parameters that changed through the administration of canagliflozin, only changes in hemoglobin significantly correlated with changes in the septal E/e' ratio (p = 0.002). In multiple regression analysis, changes in hemoglobin were also revealed to be an independent predictive factor for changes in the septal E/e' ratio. This study showed for the first time that canagliflozin could improve left ventricular diastolic function within 3 months in patients with T2DM. The benefit was especially apparent in patients with substantially improved hemoglobin values. Trial registration UMIN Clinical Trials Registry UMIN000028141.
Left ventricular geometric patterns in end-stage kidney disease: Determinants and course over time.
Nubé, Menso J; Hoekstra, Tiny; Doganer, Volkan; Bots, Michiel L; Blankestijn, Peter J; van den Dorpel, Marinus; Kamp, Otto; Ter Wee, Piet M; de Roij van Zuijdewijn, Camiel L M; Grooteman, Muriel P C
2018-02-20
While concentric left ventricular hypertrophy (cLVH) predominates in non-dialysis-dependent chronic kidney disease (CKD), eccentric left ventricular hypertrophy (eLVH) is most prevalent in dialysis-dependent CKD stage 5 (CKD5D). In these patients, the risk of sudden death is 5× higher than in individuals with cLVH. Currently, it is unknown which factors determine left ventricular (LV) geometry and how it changes over time in CKD5D. Data from participants of the CONvective TRAnsport Study who underwent serial transthoracic echocardiography were used. Based on left ventricular mass (LVM) and relative wall thickness (RWT), 4 types of left ventricular geometry were distinguished: normal, concentric remodeling, eLVH, and cLVH. Determinants of eLVH were assessed with logistic regression. Left ventricular geometry of patients who died and survived were compared. Long-term changes in RWT and LVM were evaluated with a linear mixed model. Three hundred twenty-two patients (63.1 ± 13.3 years) were included. At baseline, LVH was present in 71% (cLVH: 27%; eLVH: 44%). Prior cardiovascular disease (CVD) was positively associated with eLVH and ß-blocker use inversely. None of the putative volume parameters showed any relationship with eLVH. Although eLVH was most prevalent in non-survivors, the distribution of left ventricular geometry did not vary over time. The finding that previous CVD was positively associated with eLVH may result from the permanent high cardiac output and the strong tendency for aortic valve calcification in this group of long-term hemodialysis patients, who suffer generally also from chronic anemia and various other metabolic derangements. No association was found between eLVH and parameters of fluid balance. The distribution of left ventricular geometry did not alter over time. The assumption that LV geometry worsens over time in susceptible individuals, who then suffer from a high risk of dying, may explain these findings. © 2018 The Authors Hemodialysis International published by Wiley Periodicals, Inc. on behalf of International Society for Hemodialysis.
Bonow, R O; Ostrow, H G; Rosing, D R; Cannon, R O; Lipson, L C; Maron, B J; Kent, K M; Bacharach, S L; Green, M V
1983-11-01
To investigate the effects of verapamil on left ventricular systolic and diastolic function in patients with hypertrophic cardiomyopathy, we studied 14 patients at catheterization with a nonimaging scintillation probe before and after serial intravenous infusions of low-, medium-, and high-dose verapamil (total dose 0.17 to 0.72 mg/kg). Percent change in radionuclide stroke counts after verapamil correlated well with percent change in thermodilution stroke volume (r = .87), and changes in diastolic and systolic counts were used to assess relative changes in left ventricular volumes after verapamil. Verapamil produced dose-related increases in end-diastolic counts (19 +/- 9% increase; p less than .001), end-systolic counts (91 +/- 54% increase; p less than .001), and stroke counts (7 +/- 10% increase; p less than .02). This was associated with a decrease in ejection fraction (83 +/- 8% control, 73 +/- 10% verapamil; p less than .001) and, in the 10 patients with left ventricular outflow tract gradients, a reduction in gradient (62 +/- 27 mm Hg control, 32 +/- 35 mm Hg verapamil; p less than .01). The end-systolic pressure-volume relation was shifted downward and rightward in all patients, suggesting a negative inotropic effect. In 10 patients, left ventricular pressure-volume loops were constructed with simultaneous micromanometer pressure recordings and the radionuclide time-activity curve. In five patients, verapamil shifted the diastolic pressure-volume curve downward and rightward, demonstrating improved pressure-volume relations despite the negative inotropic effect, and also increased the peak rate of rapid diastolic filling. In the other five patients, the diastolic pressure-volume relation was unaltered by verapamil, and increased end-diastolic volumes occurred at higher end-diastolic pressures; in these patients, the peak rate of left ventricular diastolic filling was not changed by verapamil. The negative inotropic effects of intravenous verapamil are potentially beneficial in patients with hypertrophic cardiomyopathy by decreasing left ventricular contractile function and increasing left ventricular volume. Verapamil also enhances left ventricular diastolic filling and improves diastolic pressure-volume relations in some patients despite its negative inotropic effect.
Scandura, Salvatore; Dipasqua, Fabio; Gargiulo, Giuseppe; Capodanno, Davide; Caggegi, Anna; Grasso, Carmelo; Mangiafico, Sarah; Pistritto, Anna Maria; Immè, Sebastiano; Chiarandà, Marta; Ministeri, Margherita; Ronsivalle, Giuseppe; Cannata, Stefano; Arcidiacono, Antonio Andrea; Capranzano, Piera; Tamburino, Corrado
2016-11-01
To appraise the early effect of percutaneous mitral valve repair with the MitraClip system on myocardial function using real-time three-dimensional speckle-tracking echocardiography (3D-STE). Consecutive patients with moderate-to-severe or severe mitral regurgitation, undergoing mitral valve repair with the MitraClip system, were prospectively evaluated during the peri-procedural workout and follow-up. Left ventricular deformation was evaluated by a two-dimensional and 3D speckle-tracking analysis. 3D-STE acquisitions were elaborated obtaining real-time 3D global longitudinal strain evaluation, and by appraising both volumetric and hemodynamic parameters (i.e. left ventricular end-diastolic volume, left ventricular end-systolic volume, left ventricular ejection fraction, cardiac output, and stroke volume). In all, 30 patients were included. At 1-month follow-up, 3D-STE analysis revealed no changes in left ventricular end-diastolic volume (162.6 ± 73.7 ml at baseline vs. 159.8 ± 64.5 ml at 1-month follow-up; P = 0.63) and a downward trend in left ventricular end-systolic volume (104.7 ± 52.0 vs. 100.1 ± 50.4 ml, respectively; P = 0.06). Left ventricular ejection fraction did not significantly increase (38.1 ± 11.3% at baseline vs. 39.4 ± 11.0% at 1-month follow-up; P = 0.20). No significant changes were reported in cardiac output (4.3 ± 2.0 l/min at baseline vs. 4.0 ± 1.5 l/min at follow-up; P = 0.377) and in stroke volume (59.5 ± 25.5 ml at baseline vs. 59.9 ± 20.7 ml at follow-up; P = 0.867). On the contrary, left ventricular deformation capability significantly improved, with the real-time 3D global longitudinal strain value changing from -9.8 ± 4.1% at baseline to -11.0 ± 4.4% at follow-up (P = 0.018). Accurately assessing myocardial function by the use of 3D-STE, this study reported irrelevant early changes in left ventricular size, but a positive effect on left ventricular deformation capability following mitral valve repair with the MitraClip system. These preliminary results need to be confirmed in larger series and extended to long-term follow-up.
Mikami, Yoko; Jolly, Umjeet; Heydari, Bobak; Peng, Mingkai; Almehmadi, Fahad; Zahrani, Mohammed; Bokhari, Mahmoud; Stirrat, John; Lydell, Carmen P; Howarth, Andrew G; Yee, Raymond; White, James A
2017-01-01
Left ventricular ejection fraction remains the primary risk stratification tool used in the selection of patients for implantable cardioverter defibrillator therapy. However, this solitary marker fails to identify a substantial portion of patients experiencing sudden cardiac arrest. In this study, we examined the incremental value of considering right ventricular ejection fraction for the prediction of future arrhythmic events in patients with systolic dysfunction using the gold standard of cardiovascular magnetic resonance. Three hundred fourteen consecutive patients with ischemic cardiomyopathy or nonischemic dilated cardiomyopathy undergoing cardiovascular magnetic resonance were followed for the primary outcome of sudden cardiac arrest or appropriate implantable cardioverter defibrillator therapy. Blinded quantification of left ventricular and right ventricular (RV) volumes was performed from standard cine imaging. Quantification of fibrosis from late gadolinium enhancement imaging was incrementally performed. RV dysfunction was defined as right ventricular ejection fraction ≤45%. Among all patients (164 ischemic cardiomyopathy, 150 nonischemic dilated cardiomyopathy), the mean left ventricular ejection fraction was 32±12% (range, 6-54%) with mean right ventricular ejection fraction of 48±15% (range, 7-78%). At a median of 773 days, 49 patients (15.6%) experienced the primary outcome (9 sudden cardiac arrest, 40 appropriate implantable cardioverter defibrillator therapies). RV dysfunction was independently predictive of the primary outcome (hazard ratio=2.98; P=0.002). Among those with a left ventricular ejection fraction >35% (N=121; mean left ventricular ejection fraction, 45±6%), RV dysfunction provided an adjusted hazard ratio of 4.2 (P=0.02). RV dysfunction is a strong, independent predictor of arrhythmic events. Among patients with mild to moderate LV dysfunction, a cohort greatly contributing to global sudden cardiac arrest burden, this marker provides robust discrimination of high- versus low-risk subjects. © 2017 American Heart Association, Inc.
Gu, Lianzhi; Pandey, Vikas; Geenen, David L.; Chowdhury, Shamim A. K.; Piano, Mariann R.
2008-01-01
Aim To determine the effects of cigarette smoke (CS) exposure on the expression/activation of mitogen-activated protein kinases (MAPKs) (extracellular signal-regulated kinase [ERK1/2], p38-kinase [p38] and c-Jun NH2–terminal protein kinase [JNK]), norepinephrine (NE) levels and myocardial structure and function. Methods Rats were randomised to two groups: CS–exposed (n = 10) or room air (CON) (n = 12). After 5 weeks, the animals underwent echocardiography with pulse-wave Doppler flow measurements. Hearts were removed for microscopy and Western blot analysis. Results CS exposure was associated with significant increases in NE urinary levels and larger ventricular dimensions (mm) (CON = left ventricular end diastolic dimension [LVEDD] 7.99 ± 0.10, LV end systolic dimension [LVESD] 4.55 ± 0.20, CS = LVEDD 8.3 ± 0.10, LVESD 5.3 ± 0.09, p = 0.026, p = 0.003). There was also evidence of systolic dysfunction in the CS-exposed group compared to the CON group (fractional shortening %, CON = 43 ± 2, CS = 36 ± .09, p = 0.010). In CS-exposed hearts, significant increases in phosphorylated p38/total p38 (0.975 ± 0.05) and phosphorylated ERK1/2/totalERK1/2 (1.919 ± 0.050) were found compared to CON hearts (0.464 ± 0.008, 0.459 ± 0.050, respectively). No significant differences were found in JNK levels between the groups. Conclusions Increased NE levels and MAPK activation are associated with CS-related left ventricular remodelling. PMID:18815071
Picca, Maurizio; Agozzino, Francesco; Pelosi, Giancarlo
2003-01-01
An increased urinary albumin excretion (UAE) is associated with an augmented risk of cardiovascular disease in diabetic patients and in non-diabetic subjects. Left ventricular hypertrophy has been demonstrated to be a powerful predictor of cardiovascular morbidity and mortality in arterial hypertension and when the ventricular geometry is concentric the relation is even stronger. This echocardiographic and Doppler study was designed to evaluate the influence of microalbuminuria on the left ventricular geometry and function in hypertensive patients with type 2 diabetes melitus. Forty-two patients (16 males, 26 females, mean age 59.6 +/- 6.7 years) with mild-to-moderate essential hypertension and type 2 diabetes mellitus were enrolled in the study. Twenty-one patients had an elevated UAE (group 1) and 21 a normal UAE (group 2). M-mode (under two-dimensional control) and Doppler echocardiography were performed after a 4-week washout period off antihypertensive therapy. The left ventricular mass index was found to be greater than the partition value of 51 g/m2.7 in both groups but was significantly higher (p < 0.001) in group 1. The midwall fractional shortening was significantly lower (p < 0.001) in group 1 in comparison with group 2. The E/A ratio was impaired in both groups but was more significantly reduced (p < 0.02) in group 1. There was a significantly higher prevalence of a left ventricular concentric hypertrophy pattern (19/21 patients, p < 0.001) in group 1. In hypertensive patients with type 2 diabetes mellitus, an elevated UAE is associated with an increased left ventricular mass index, a higher prevalence of a concentric left ventricular hypertrophy pattern, a depressed midwall systolic performance and a markedly impaired diastolic function...
Luo, Antao; Ma, Jihua; Song, Yejia; Qian, Chunping; Wu, Ying; Zhang, Peihua; Wang, Leilei; Fu, Chen; Cao, Zhenzhen; Shryock, John C
2014-02-01
An increase of cardiac late sodium current (INa.L) is arrhythmogenic in atrial and ventricular tissues, but the densities of INa.L and thus the potential relative contributions of this current to sodium ion (Na(+)) influx and arrhythmogenesis in atria and ventricles are unclear. In this study, whole-cell and cell-attached patch-clamp techniques were used to measure INa.L in rabbit left atrial and ventricular myocytes under identical conditions. The density of INa.L was 67% greater in left atrial (0.50 ± 0.09 pA/pF, n = 20) than in left ventricular cells (0.30 ± 0.07 pA/pF, n = 27, P < 0.01) when elicited by step pulses from -120 to -20 mV at a rate of 0.2 Hz. Similar results were obtained using step pulses from -90 to -20 mV. Anemone toxin II (ATX II) increased INa.L with an EC50 value of 14 ± 2 nM and a Hill slope of 1.4 ± 0.1 (n = 9) in atrial myocytes and with an EC50 of 21 ± 5 nM and a Hill slope of 1.2 ± 0.1 (n = 12) in ventricular myocytes. Na(+) channel open probability (but not mean open time) was greater in atrial than in ventricular cells in the absence and presence of ATX II. The INa.L inhibitor ranolazine (3, 6, and 9 μM) reduced INa.L more in atrial than ventricular myocytes in the presence of 40 nM ATX II. In summary, rabbit left atrial myocytes have a greater density of INa.L and higher sensitivities to ATX II and ranolazine than rabbit left ventricular myocytes.
Left ventricular rotation and torsion in patients with perimembranous ventricular septal defect.
Zhuang, Yan; Yong, Yong-hong; Yao, Jing; Ji, Ling; Xu, Di
2014-03-01
Assessment of left ventricular (LV) rotation has become an important approach for quantifying LV function. In this study, we sought to analyze LV rotation and twist using speckle tracking imaging (STI) in adult patients with isolated ventricular septal defects. Using STI, the peak rotation and time to peak rotation of 6 segments in basal and apical short-axis were measured, respectively, in 32 patients with ventricular septal defect and 30 healthy subjects as controls. The global rotation of the 6 segments in basal and apical and LV twist versus time profile were drawn, the peak rotation and twist of LV were calculated. All the time to peak rotation/twist were expressed as a percentage of end-systole (end-systole = 100%). Left ventricular ejection fraction was measured by biplane Simpson method. In patients group, the peak rotation of posterior, inferior, and postsept wall in basal was higher(P ≤ 0.05) and LV twist was also higher (P ≤ 0.05) than healthy controls. There were no significant differences between 2 groups in the peak rotation of the other 9 segments and left ventricular ejection fraction. Different from the control group, the time to peak rotation of the 6 segments in basal were delayed and the global rotation of the base was delayed (P ≤ 0.05) in ventricular septal defect group. Left ventricular volume overload due to ventricular septal defect has significant effect on LV rotation and twist, and LV rotation and twist may be a new index predicting LV systolic function. © 2013, Wiley Periodicals, Inc.
Histotripsy for Pediatric Cardiac Applications: In Vivo Neonatal Pig Model
NASA Astrophysics Data System (ADS)
Miller, Ryan M.; Owens, Gabe; Ensing, Gregory; Ludomirsky, Achiau; Cain, Charles; Xu, Zhen
2010-03-01
This study investigated the in vivo feasibility of using histotripsy to non-invasively create a flow channel between the ventricles by generating a perforation of the ventricular septum, clinically referred to as a ventricular septum defect (VSD). The overall goal is to develop a non-invasive procedure to aid in the treatment of neonatal patients with complex congenital heart diseases such as Hypoplastic Left Heart Syndrome (HLHS). Histotripsy is a therapeutic ultrasound technique that produces mechanical fractionation of soft tissue through controlled cavitation. The study was conducted in a live and intact neonatal pig model. The ventricular septum in the neonatal pig heart was treated with histotripsy delivered by a spherically focused 1 MHz transducer positioned outside the chest wall. Histotripsy treatment was applied using 5-cycle ultrasound pulses at 1 kHz pulse repetition frequency with 12-18 MPa peak negative pressure. The treatment was guided and monitored with ultrasound imaging. In all nine subjects treated, a bubble cloud was generated on the ventricular septum using histotripsy, and visualized with ultrasound imaging. Within 20 seconds to 4 minutes following the initiation of a bubble cloud, a VSD was created in all nine pigs and confirmed by the detection of blood flow through the ventricular septum with color Doppler ultrasound. Gross morphology and histology on all hearts showed a demarcated perforation in the ventricular septum. This study shows that a VSD can be created in an intact neonatal animal using extracorporeal histotripsy under real-time ultrasound guidance.
Castelvecchio, Serenella; Careri, Giulia; Ambrogi, Federico; Camporeale, Antonia; Menicanti, Lorenzo; Secchi, Francesco; Lombardi, Massimo
2018-01-01
Post-infarction myocardial scar causes adverse left ventricular remodelling and negatively affects the prognosis. We sought to investigate whether scar extent and location obtained by cardiac magnetic resonance may affect the reverse remodelling and survival of heart failure patients undergoing surgical ventricular reconstruction. From January 2011 to December 2015, 151 consecutive patients with previous myocardial infarction and left ventricular remodelling underwent surgical ventricular reconstruction at our Institution, of which 88 (58%) patients had a preoperative protocol-standardized late gadolinium enhancement (LGE)-cardiac magnetic resonance examination during the week before surgery. We excluded 40 patients with devices (26%), 15 patients with irregular heart rhythm (permanent atrial fibrillation, 10% not included in the device group) or mixed contraindications (severe claustrophobia or presence of material magnetic resonance not compatible). Among the 145 survivors, 11 patients received an implantable cardioverter defibrillator after surgery (mostly for persistent low ejection fraction) and were excluded as well, yielding a total of 59 patients (48 men, aged 65 ± 9 years) who repeated a protocol-standardized LGE-cardiac magnetic resonance examination even 6 months postoperatively and therefore represent the study population. Patients were grouped according to the presence of LGE in the antero-basal left ventricular segments (Group A) or the absence of LGE in the same segments (Group B). The postoperative left ventricular end-systolic volume index was considered the primary end-point. After surgery, left ventricular end-systolic volume index and end-diastolic volume index significantly decreased (P < 0.001, for both), while diastolic sphericity index and ejection fraction significantly increased (P = 0.015 and P < 0.001, respectively). The presence of LGE in the antero-basal left ventricular segments (10 patients, Group A) was the only independent predictor of outcome (P = 0.02) at multivariate analysis, being the postoperative left ventricular end-systolic volume index significantly higher compared to that of patients of Group B (49 patients) (78 ± 26 ml/m2 vs 55 ± 20 ml/m2, P = 0.003). Furthermore, patients with a postoperative left ventricular end-systolic volume index >60 ml/m2 showed a higher risk of cardiac events (hazard ratio = 3.67, P = 0.02). In patients undergoing surgical ventricular reconstruction, LGE scar location affects the left ventricular reverse remodelling, which in turn might limit the survival benefit. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Di Molfetta, Arianna; Ferrari, Gianfranco; Iacobelli, Roberta; Filippelli, Sergio; Fresiello, Libera; Gagliardi, Maria G; Toscano, Alessandro; Trivella, Maria G; Amodeo, Antonio
2015-12-01
Right ventricular failure (RVF) is one of the major complications during LVAD. Apart from drug therapy, the most reliable option is the implantation of RVAD. However, BIVAD have a poor prognosis and increased complications. Experiments have been conducted on alternative approaches, such as the creation of an atrial septal defect (ASD), a cavo-aortic shunt (CAS) including the LVAD and a cavo-pulmonary connection (CPC). This work aims at realizing a lumped parameter model (LPM) to compare the acute hemodynamic effects of ASD, CPC, CAS, RVAD in LVAD pediatric patients with RVF. Data of 5 pediatric patients undergoing LVAD were retrospectively collected to reproduce patients baseline hemodynamics with the LPM. The effects of continuous flow LVAD implantation complicated by RVF was simulated and then the effects of ASD, CPC, CAS and RVAD treatments were simulated for each patient. The model successfully reproduced patients' baseline and the hemodynamic effects of the surgical strategies. Simulating the different surgical strategies, an unloading of the right ventricle and an increment of left ventricular preload were observed with an improvement of the hemodynamics (total cardiac output: ASD +15%, CPC +10%, CAS +70% RVAD +20%; right ventricular external work: ASD -19%, CPC -46%, CAS -76%, RVAD -32%; left ventricular external work: ASD +12%, CPC +28%, RVAD +64%). The use of numerical model could offer an additional support for clinical decision-making, also potentially reducing animal experiments, to compare the outcome of different surgical strategies to treat RVF in LVAD.
EDUCATIONAL SERIES IN CONGENITAL HEART DISEASE: Congenital left-sided heart obstruction
Carr, Michelle; Curtis, Stephanie; Marek, Jan
2018-01-01
Congenital obstruction of the left ventricular outflow tract remains a significant problem and multilevel obstruction can often coexist. Obstruction can take several morphological forms and may involve the subvalvar, valvar or supravalvar portion of the aortic valve complex. Congenital valvar stenosis presenting in the neonatal period represents a spectrum of disorders ranging from the hypoplastic left heart syndrome to almost normal hearts. Treatment options vary dependent on the severity of the left ventricular outflow tract obstruction (LVOTO) and the variable degree of left ventricular hypoplasia as well as the associated lesions such as arch hypoplasia and coarctation. PMID:29681546
A D-Shaped Bileaflet Bioprosthesis which Replicates Physiological Left Ventricular Flow Patterns
Tan, Sean Guo-Dong; Kim, Sangho; Hon, Jimmy Kim Fatt; Leo, Hwa Liang
2016-01-01
Prior studies have shown that in a healthy heart, there exist a large asymmetric vortex structure that aids in establishing a steady flow field in the left ventricle. However, the implantation of existing artificial heart valves at the mitral position is found to have a negative effect on this physiological flow pattern. In light of this, a novel D-shaped bileaflet porcine bioprosthesis (GD valve) has been designed based on the native geometry mitral valve, with the hypothesis that biomimicry in valve design can restore physiological left ventricle flow patterns after valve implantation. An in-vitro experiment using two dimensional particle velocimetry imaging was carried out to determine the hemodynamic performance of the new bileaflet design and then compared to that of the well-established St. Jude Epic valve which functioned as a control in the experiment. Although both valves were found to have similar Reynolds shear stress and Turbulent Kinetic Energy levels, the novel D-shape valve was found to have lower turbulence intensity and greater mean kinetic energy conservation. PMID:27258099
Dekker, A L A J; Phelps, B; Dijkman, B; van der Nagel, T; van der Veen, F H; Geskes, G G; Maessen, J G
2004-06-01
Patients in heart failure with left bundle branch block benefit from cardiac resynchronization therapy. Usually the left ventricular pacing lead is placed by coronary sinus catheterization; however, this procedure is not always successful, and patients may be referred for surgical epicardial lead placement. The objective of this study was to develop a method to guide epicardial lead placement in cardiac resynchronization therapy. Eleven patients in heart failure who were eligible for cardiac resynchronization therapy were referred for surgery because of failed coronary sinus left ventricular lead implantation. Minithoracotomy or thoracoscopy was performed, and a temporary epicardial electrode was used for biventricular pacing at various sites on the left ventricle. Pressure-volume loops with the conductance catheter were used to select the best site for each individual patient. Relative to the baseline situation, biventricular pacing with an optimal left ventricular lead position significantly increased stroke volume (+39%, P =.01), maximal left ventricular pressure derivative (+20%, P =.02), ejection fraction (+30%, P =.007), and stroke work (+66%, P =.006) and reduced end-systolic volume (-6%, P =.04). In contrast, biventricular pacing at a suboptimal site did not significantly change left ventricular function and even worsened it in some cases. To optimize cardiac resynchronization therapy with epicardial leads, mapping to determine the best pace site is a prerequisite. Pressure-volume loops offer real-time guidance for targeting epicardial lead placement during minimal invasive surgery.
Oxidative stress contributes to methamphetamine-induced left ventricular dysfunction.
Lord, Kevin C; Shenouda, Sylvia K; McIlwain, Elizabeth; Charalampidis, Dimitrios; Lucchesi, Pamela A; Varner, Kurt J
2010-07-01
Our aim was to test the hypothesis that the repeated, binge administration of methamphetamine would produce oxidative stress in the myocardium leading to structural remodeling and impaired left ventricular function. Echocardiography and Millar pressure-volume catheters were used to monitor left ventricular structure and function in rats subjected to four methamphetamine binges (3 mg/kg, iv for 4 days, separated by a 10-day drug-free period). Hearts from treated and control rats were used for histological or proteomic analysis. When compared with saline treatment, four methamphetamine binges produced eccentric left ventricular hypertrophy. The drug also significantly impaired systolic function (decreased fractional shortening, ejection fraction, and adjusted maximal power) and produced significant diastolic dysfunction (increased -dP/dt and tau). Dihydroethedium staining showed that methamphetamine significantly increased (285%) the levels of reactive oxygen species in the left ventricle. Treatment with methamphetamine also resulted in the tyrosine nitration of myofilament (desmin, myosin light chain) and mitochondrial (ATP synthase, NADH dehydrogenase, cytochrome c oxidase, prohibitin) proteins. Treatment with the superoxide dismutase mimetic, tempol in the drinking water prevented methamphetamine-induced left ventricular dilation and systolic dysfunction; however, tempol (2.5 mM) did not prevent the diastolic dysfunction. Tempol significantly reduced, but did not eliminate dihydroethedium staining in the left ventricle, nor did it prevent the tyrosine nitration of mitochondrial and contractile proteins. This study shows that oxidative stress plays a significant role in mediating methamphetamine-induced eccentric left ventricular dilation and systolic dysfunction.
Oxidative stress contributes to methamphetamine-induced left ventricular dysfunction
Lord, Kevin C.; Shenouda, Sylvia K.; McIlwain, Elizabeth; Charalampidis, Dimitrios; Lucchesi, Pamela A.; Varner, Kurt J.
2010-01-01
Aims Our aim was to test the hypothesis that the repeated, binge administration of methamphetamine would produce oxidative stress in the myocardium leading to structural remodeling and impaired left ventricular function. Methods and results Echocardiography and Millar pressure–volume catheters were used to monitor left ventricular structure and function in rats subjected to four methamphetamine binges (3 mg/kg, iv for 4 days, separated by a 10-day drug-free period). Hearts from treated and control rats were used for histological or proteomic analysis. When compared with saline treatment, four methamphetamine binges produced eccentric left ventricular hypertrophy. The drug also significantly impaired systolic function (decreased fractional shortening, ejection fraction, and adjusted maximal power) and produced significant diastolic dysfunction (increased −dP/dt and tau). Dihydroethedium staining showed that methamphetamine significantly increased (285%) the levels of reactive oxygen species in the left ventricle. Treatment with methamphetamine also resulted in the tyrosine nitration of myofilament (desmin, myosin light chain) and mitochondrial (ATP synthase, NADH dehydrogenase, cytochrome c oxidase, prohibitin) proteins. Treatment with the superoxide dismutase mimetic, tempol in the drinking water prevented methamphetamine-induced left ventricular dilation and systolic dysfunction; however, tempol (2.5 mM) did not prevent the diastolic dysfunction. Tempol significantly reduced, but did not eliminate dihydroethedium staining in the left ventricle, nor did it prevent the tyrosine nitration of mitochondrial and contractile proteins. Conclusion This study shows that oxidative stress plays a significant role in mediating methamphetamine-induced eccentric left ventricular dilation and systolic dysfunction. PMID:20139112
Double-chambered left ventricle in a cat.
Smith, Paul J; Tarazi, Marwan N; Ho, Siew Yen
2014-06-01
Double-chambered left ventricle is a rare congenital disorder in which the left ventricular cavity is subdivided into two cavities by an anomalous septum or muscle band. We describe a case of double-chambered left ventricle, most likely caused by the presence of excessive left ventricular bands, in an asymptomatic cat. Copyright © 2014 Elsevier B.V. All rights reserved.
Treatment of dilated cardiomyopathy with carvedilol in children.
Erdoğan, Ilkay; Ozer, Sema; Karagöz, Tevfik; Celiker, Alpay; Ozkutlu, Süheyla; Alehan, Dursun
2009-01-01
We performed a study to examine the clinical use of carvedilol, its dosage and its effects on systolic functions in children. Twenty-one patients with dilated cardiomyopathy who were treated with carvedilol adjacent to standard heart failure therapy were enrolled in the study. Echocardiographic assessment was obtained before and during carvedilol therapy, and left ventricular fractional shortening and left ventricular ejection fraction were determined in order to estimate left ventricular function. At a follow-up of six months, left ventricular ejection fraction and fractional shortening significantly improved from 38 +/- 10% to 53 +/- 13% and from 19 +/- 6 % to 27 +/- 8%, respectively, following carvedilol treatment. The results of the present study indicate that carvedilol is well tolerated in children with dilated cardiomyopathy and there is a significant improvement in the clinical status and left ventricular ejection fraction in patients not responding to conventional therapy. Patient selection criteria, optimal timing of carvedilol therapy, its dosage and its long-term effects need to be investigated with multi-institutional trials and large numbers of patients.
NASA Technical Reports Server (NTRS)
Bauer, F.; Shiota, T.; Qin, J. X.; White, R. D.; Thomas, J. D.
2001-01-01
The measurement of the left ventricular ejection fraction is important for the evaluation of cardiomyopathy and depends on the measurement of left ventricular volumes. There are no existing conventional echocardiographic means of measuring the true left atrial and ventricular volumes without mathematical approximations. The aim of this study was to test anew real time 3-dimensional echocardiographic system of calculating left atrial and ventricular volumes in 40 patients after in vitro validation. The volumes of the left atrium and ventricle acquired from real time 3-D echocardiography in the apical view, were calculated in 7 sections parallel to the surface of the probe and compared with atrial (10 patients) and ventricular (30 patients) volumes calculated by nuclear magnetic resonance with the simpson method and with volumes of water in balloons placed in a cistern. Linear regression analysis showed an excellent correlation between the real volume of water in the balloons and volumes given in real time 3-dimensional echocardiography (y = 0.94x + 5.5, r = 0.99, p < 0.001, D = -10 +/- 4.5 ml). A good correlation was observed between real time 3-dimensional echocardiography and nuclear magnetic resonance for the measurement of left atrial and ventricular volumes (y = 0.95x - 10, r = 0.91, p < 0.001, D = -14.8 +/- 19.5 ml and y = 0.87x + 10, r = 0.98, P < 0.001, D = -8.3 +/- 18.7 ml, respectively. The authors conclude that real time three-dimensional echocardiography allows accurate measurement of left heart volumes underlying the clinical potential of this new 3-D method.
Yu, Teng-Hung; Tang, Wei-Hua; Lu, Yung-Chuan; Wang, Chao-Ping; Hung, Wei-Chin; Wu, Cheng-Ching; Tsai, I-Ting; Chung, Fu-Mei; Houng, Jer-Yiing; Lan, Wen-Chun; Lee, Yau-Jiunn
2018-05-22
Left ventricular hypertrophy (LVH) is one of the most common cardiac abnormalities in patients with end-stage renal disease. Hippuric acid (HA), a harmful uremic toxin, is known to be elevated in patients with uremia, and serum HA levels are associated with neurological symptoms, metabolic acidosis, and accelerated renal damage associated with chronic kidney disease. However, the pathophysiological role of HA in patients with uremia remains unclear. We investigated the association between serum HA levels and echocardiographic measurements in patients undergoing hemodialysis (HD) treatment. Eighty consecutive patients treated at a single HD center (44 males, 36 females; mean age 66 y, mean HD duration 6 y) were included in this study. Comprehensive echocardiography was performed after HD. Blood samples were obtained before HD. Pearson's correlation analysis revealed that serum HA levels were positively correlated with diastolic blood pressure, serum creatinine, left ventricular mass index, end diastolic interventricular septal thickness, left ventricular end-diastolic diameter, left ventricular end systolic diameter, end systolic left ventricular posterior wall thickness, and left atrium diameter, and negatively correlated with age. Furthermore, the HD patients with LVH had higher median serum HA levels than those without LVH (34.2 vs. 18.1 μg/ml, p = 0.003). Multiple logistic regression analysis revealed that HA was independently associated with LVH even after adjusting for known biomarkers. Moreover, the receiver operator characteristics curve of HA showed that a HA level of >26.9 μg/ml was associated with LVH. HA was significantly associated with LVH. HA could be a novel biomarker of left ventricular overload, which is closely associated with an increased risk of death in HD patients. Copyright © 2018 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hurford, W.; Lowenstein, E.; Zapol, W.
1985-05-01
To determine whether branched chain fatty acid extraction is reduced during right ventricular (RV) dysfunction due to acute pulmonary artery hypertension, studies were done in 6 anesthetized dogs. Regional branched chain fatty acid extraction was measured by comparing the myocardial uptake of I-125 labeled 15-(p-(iodophenyl))-3-methylpentadecanoic acid (I-PDA) to myocardial blood flow. Acute pulmonary hypertension was induced by incremental intravenous injection of 100 micron diameter glass beads into six pentobarbital anesthetized, mechanically ventilated dogs. Myocardial blood flow was measured by radiolabeled microspheres both under baseline conditions and during pulmonary hypertension. Mean RV pressure rose from 12 +- 2 (mean +- SEM)more » to 30 +-3mmHg resulting in a 225 +- 16% increase in RV stroke work. RV ejection fraction, as assessed by gated blood pool scans fell from 39 +- 2 to 18 +- 2%. Left ventricular (LV) pressures, stroke work and ejection fraction were unchanged. Myocardial blood flow increased 132 + 59% in the RV free wall and 67 +- 22% in the RV septum. LV blood flow was unchanged. Despite increased RV work and myocardial blood flow, no differences were noted in the branched chain fatty acid extraction ratios among LV or RV free walls or septum. The authors conclude that early RV dysfunction associated with pulmonary artery hypertension is not due to inadequate myocardial blood flow or branched chain fatty acid extraction.« less
Saeki, A; Recchia, F A; Senzaki, H; Kass, D A
1996-01-01
1. The role of nitric oxide (NO) in the regulation of basal coronary perfusion and ventricular chamber energetics was studied in isovolumetrically contracting isolated blood-perfused canine hearts. Hearts were cross-perfused by a donor animal prior to isolation, and chamber volume controlled by a servo-pump. Coronary sinus flow and arterial-coronary sinus oxygen difference were measured to determine energetic efficiency. 2. NO synthase (NOS) was competitively inhibited by NG-monomethyl-L-arginine (L-NMMA; 0.5 mg kg-1, intracoronary), resulting in a reduction of acetylcholine (50 micrograms min-1)-induced flow augmentation from 143 to 62% (P < 0.001). 3. NOS inhibition had no significant effect on basal coronary flow. Coronary pressure-flow relationships were determined at a constant cardiac workload by varying mean perfusion pressure between 20 and 150 mmHg. Neither the shape of the relationship, nor the low-pressure value at which flow regulation was substantially diminished were altered by NOS inhibition. 4. Myocardial efficiency was assessed by the relationship between myocardial oxygen consumption and total pressure-volume area (PVA), with cavity volume altered to generate varying PVAs. This relative load-independent measure of energetic efficiency was minimally altered by NOS inhibition. 5. These results contrast with isolated crystalloid-perfused heart experiments and suggest that in hearts with highly controlled ventricular loading and whole-blood perfusion, effects of basal NO production on coronary perfusion and left ventricular energetics are minimal. PMID:8866868
Patent ductus arteriosus associated with congenital anomaly of coronary artery.
Maleki, Majid; Azizian, Nassrin; Esmaeilzadeh, Maryam; Moradi, Bahieh
2013-11-01
We reported a case of patent ductus arteriosus (PDA) with congenital anomaly of coronary arteries as abnormal origin of right coronary artery (RCA) and left coronary artery (LCA) from a single ostium of the right coronary sinus. A 21-year-old man referred to our institution for evaluation of cardiac murmur. He has suffered from palpitation and atypical chest pain for three months. On physical examination, a continuous murmur was heard in the second left parasternal space. Transthoracic echocardiography showed normal left and right ventricular size and systolic function (LVEF = 55%). Main pulmonary artery (PA) and left pulmonary artery (LPA) branch were considerably dilated. Considering normal coronary flow, lack of clinical evidence of myocardial ischemia and echocardiography findings, patient underwent surgical closure of PDA via left thoracotomy and after five days discharged uneventfully.
Loomba, Rohit S; Shah, Parinda H; Nijhawan, Karan; Aggarwal, Saurabh; Arora, Rohit
2015-03-01
Increased cardiothoracic ratio noted on chest radiographs often prompts concern and further evaluation with additional imaging. This study pools available data assessing the utility of cardiothoracic ratio in predicting left ventricular dilation. A systematic review of the literature was conducted to identify studies comparing cardiothoracic ratio by chest x-ray to left ventricular dilation by echocardiography. Electronic databases were used to identify studies which were then assessed for quality and bias, with those with adequate quality and minimal bias ultimately being included in the pooled analysis. The pooled data were used to determine the sensitivity, specificity, positive predictive value and negative predictive value of cardiomegaly in predicting left ventricular dilation. A total of six studies consisting of 466 patients were included in this analysis. Cardiothoracic ratio had 83.3% sensitivity, 45.4% specificity, 43.5% positive predictive value and 82.7% negative predictive value. When a secondary analysis was conducted with a pediatric study excluded, a total of five studies consisting of 371 patients were included. Cardiothoracic ratio had 86.2% sensitivity, 25.2% specificity, 42.5% positive predictive value and 74.0% negative predictive value. Cardiothoracic ratio as determined by chest radiograph is sensitive but not specific for identifying left ventricular dilation. Cardiothoracic ratio also has a strong negative predictive value for identifying left ventricular dilation.
Effect of HeartMate left ventricular assist device on cardiac autonomic nervous activity.
Kim, S Y; Montoya, A; Zbilut, J P; Mawulawde, K; Sullivan, H J; Lonchyna, V A; Terrell, M R; Pifarré, R
1996-02-01
Clinical performance of a left ventricular assist device is assessed via hemodynamic parameters and end-organ function. This study examined effect of a left ventricular assist device on human neurophysiology. This study evaluated the time course change of cardiac autonomic activity of 3 patients during support with a left ventricular assist device before cardiac transplantation. Cardiac autonomic activity was determined by power spectral analysis of short-term heart rate variability. The heart rate variability before cardiac transplantation was compared with that on the day before left ventricular assist device implantation. The standard deviation of the mean of the R-R intervals of the electrocardiogram, an index of vagal activity, increased to 27 +/- 7 ms from 8 +/- 0.6 ms. The modulus of power spectral components increased. Low frequency (sympathetic activity) and high frequency power (vagal activity) increased by a mean of 9 and 22 times of each baseline value (low frequency power, 5.2 +/- 3.0 ms2; high frequency power, 2.1 +/- 0.7 ms2). The low over high frequency power ratio decreased substantially, indicating an improvement of cardiac sympatho-vagal balance. The study results suggest that left ventricular assist device support before cardiac transplantation may exert a favorable effect on cardiac autonomic control in patients with severe heart failure.
Doppler echocardiographic analysis of left ventricular filling in treated hypertensive patients.
Phillips, R A; Coplan, N L; Krakoff, L R; Yeager, K; Ross, R S; Gorlin, R; Goldman, M E
1987-02-01
Early detection and prevention of cardiac dysfunction is an important goal in the management of hypertensive patients. In this study, Doppler echocardiography was used to evaluate the pattern of left ventricular diastolic filling in 38 subjects: 18 treated hypertensive patients (blood pressure 141 +/- 17/83 +/- 10 mm Hg, mean +/- SD) without other coronary risk factors and 20 risk-free normotensive subjects of similar age (47 +/- 10 and 49 +/- 13 years, respectively). Peak velocity of late left ventricular filling due to the atrial contraction was greater in hypertensive compared with normotensive subjects (69 +/- 14 versus 52 +/- 13 cm/s; p less than 0.001). Peak velocity of late filling was significantly greater in hypertensive versus normotensive subjects in those aged 50 years or younger and those older than age 50 (65 +/- 12 versus 50 +/- 11; p less than 0.01 and 75 +/- 15 versus 56 +/- 15 cm/s; p less than 0.05, respectively). In hypertensive subjects, peak velocity of late filling did not correlate with routine indexes of hypertensive heart disease (including posterior wall thickness and left ventricular mass), systolic and diastolic blood pressure or duration of hypertension. These results indicate that increased velocity of late left ventricular filling may be independent of left ventricular hypertrophy and persist despite effective blood pressure control.
Functional morphology and patterns of blood flow in the heart of Python regius.
Starck, J Matthias
2009-06-01
Brightness-modulated ultrasonography, continuous-wave Doppler, and pulsed-wave Doppler-echocardiography were used to analyze the functional morphology of the undisturbed heart of ball pythons. In particular, the action of the muscular ridge and the atrio-ventricular valves are key features to understand how patterns of blood flow emerge from structures directing blood into the various chambers of the heart. A step-by-step image analysis of echocardiographs shows that during ventricular diastole, the atrio-ventricular valves block the interventricular canals so that blood from the right atrium first fills the cavum venosum, and blood from the left atrium fills the cavum arteriosum. During diastole, blood from the cavum venosum crosses the muscular ridge into the cavum pulmonale. During middle to late systole the muscular ridge closes, thus prohibiting further blood flow into the cavum pulmonale. At the same time, the atrio-ventricular valves open the interventricular canal and allow blood from the cavum arteriosum to flow into the cavum venosum. In the late phase of ventricular systole, all blood from the cavum pulmonale is pressed into the pulmonary trunk; all blood from the cavum venosum is pressed into both aortas. Quantitative measures of blood flow volume showed that resting snakes bypass the pulmonary circulation and shunt about twice the blood volume into the systemic circulation as into the pulmonary circulation. When digesting, the oxygen demand of snakes increased tremendously. This is associated with shunting more blood into the pulmonary circulation. The results of this study allow the presentation of a detailed functional model of the python heart. They are also the basis for a functional hypothesis of how shunting is achieved. Further, it was shown that shunting is an active regulation process in response to changing demands of the organism (here, oxygen demand). Finally, the results of this study support earlier reports about a dual pressure circulation in Python regius.
Vanoverschelde, J L; Wijns, W; Michel, X; Cosyns, J; Detry, J M
1991-11-01
Asynchronous segmental early relaxation, defined as a localized early segmental outward motion of the left ventricular endocardium during isovolumetric relaxation, has been associated with an altered left ventricular relaxation rate. To determine whether asynchronous segmental early relaxation also results in impaired left ventricular filling, early diastolic ventricular wall motion and Doppler-derived left ventricular filling indexes were examined in 25 patients with documented coronary artery disease and normal systolic function. Patients were further classified into two groups according to the presence (n = 15, group 1) or absence (n = 10, group 2) of asynchronous early relaxation at left ventriculography. A third group of 10 age-matched normal subjects served as a control group. No differences were observed between the two patient groups with coronary artery disease with respect to age, gender distribution, heart rate, left ventricular systolic and diastolic pressures or extent and severity of coronary artery disease. No differences in transmitral filling dynamics were observed between group 2 patients and age-matched control subjects. Conversely, group 1 patients had significantly lower peak early filling velocities (44 +/- 11 vs. 58 +/- 11 cm/s, p less than 0.01), larger atrial filling fraction (45 +/- 4% vs. 38 +/- 4%, p less than 0.001), lower ratio of early to late transmitral filling velocities (0.6 +/- 0.08 vs. 0.99 +/- 0.18, p less than 0.001) and a longer isovolumetric relaxation period (114 +/- 12 vs. 90 +/- 6 ms, p less than 0.001) compared with group 2 patients and control subjects.(ABSTRACT TRUNCATED AT 250 WORDS)
Petretta, M; Bonaduce, D; Spinelli, L; Vicario, M L; Nuzzo, V; Marciano, F; Camuso, P; De Sanctis, V; Lupoli, G
2001-12-01
To characterize cardiac structure and function and cardiac autonomic control in patients with subclinical and overt hyperthyroidism. Thirty patients with subclinical hyperthyroidism and 30 with overt disease were selected from patients never previously treated for endocrinological disease in the outpatient clinic of our institution. Twenty normal individuals were studied as control group. Left ventricular structure and function and cardiac autonomic control were evaluated, respectively, by two-dimensional Doppler echocardiography and by 24-h Holter recording with heart rate variability analysis. Patients with overt hyperthyroidism showed greater values of left ventricular end-diastolic volume (P<0.05) and left ventricular mass (P<0.05) than patients with subclinical disease. In addition, the mean velocity of left ventricular fibre shortening (P<0.05) and left ventricular ejection fraction (P<0.05) were greater in patients with overt hyperthyroidism than in patients with subclinical disease. No difference in any of these parameters was detectable between normal subjects and patients with subclinical disease. The isovolumic relaxation period was shorter in patients with subclinical hyperthyroidism than in control individuals (P<0.05) and in patients with overt hyperthyroidism (P<0.05). As regards cardiac autonomic control, all time and frequency domain measures decreased progressively from control individuals to patients with subclinical hyperthyroidism and those with overt disease (P<0.001). Thyrotoxic patients show changes in left ventricular structure and increased echocardiographic indexes of myocardial contractility, whereas the only echocardiographic feature detectable in patients with subclinical hyperthyroidism is an increased velocity of left ventricular relaxation. Cardiac parasympathetic withdrawal is evident in patients with overt hyperthyroidism and in patients with subclinical disease.
Thomas, J D; Flachskampf, F A; Chen, C; Guererro, J L; Picard, M H; Levine, R A; Weyman, A E
1992-11-01
The isovolumic relaxation time (IVRT) is an important noninvasive index of left ventricular diastolic function. Despite its widespread use, however, the IVRT has not been related analytically to invasive parameters of ventricular function. Establishing such a relationship would make the IVRT more useful by itself and perhaps allow it to be combined more precisely with other noninvasive parameters of ventricular filling. The purpose of this study was to validate such a quantitative relationship. Assuming isovolumic relaxation to be a monoexponential decay of ventricular pressure (pv) to a zero-pressure asymptote, it was postulated that the time interval from aortic valve closure (when pv = p(o)) until mitral valve opening (when pv = left atrial pressure, pA) would be given analytically by IVRT = tau[log(p(o))-log(pA)], where tau is the time constant of isovolumic relaxation and log is to the base e. To test this hypothesis we analyzed data from six canine experiments in which ventricular preload and afterload were controlled nonpharmacologically. In addition, tau was adjusted with the use of beta-adrenergic blockade and calcium infusion, as well as with hypothermia. In each experiment data were collected before and after the surgical formation of mitral stenosis, performed to permit the study of a wide range of left atrial pressures. High-fidelity left atrial, left ventricular, and aortic root pressures were digitized, the IVRT was measured from the aortic dicrotic notch until the left atrioventricular pressure crossover point, and tau was calculated by nonlinear least-squares regression.(ABSTRACT TRUNCATED AT 250 WORDS)
Fresiello, Libera; Gu, Y John; Ferrari, Gianfranco; Di Molfetta, Arianna; Rakhorst, Gerhard
2011-05-01
The pulsatile catheter pump (PUCA pump) is a left ventricular assist device that provides additional flow to the left ventricle. It is usually run in order to ensure a counterpulsation effect, as in the case of the intra-aortic balloon pump (IABP). Because of this similarity, a comparison between the PUCA pump and the IABP was conducted from both the hemodynamic and energetic points of view. Numerical models of the two devices were created and connected to the CARDIOSIM cardiovascular simulator. The PUCA and IABP models were then verified using in vivo experimental data and literature data, respectively. Numerical experiments were conducted for different values of left ventricular end systolic elastance (Els) and systemic arterial compliance (Csa). The energetic comparison was conducted taking into account the diastolic pressure time index and the endocardial viability ratio. Hemodynamic results expressed as cardiac output (CO) and mean coronary blood flow (CBF) show that both the IABP and the PUCA pump efficacy decrease with higher values of Els and Csa. The IABP especially shows higher sensitivity to these parameters, to the extent that in some cases CO actually drops and CBF does not increase. On the other hand, for lower values of Csa, IABP performance improves so much that the PUCA pump flow needs to be increased in order to ensure a hemodynamic effect comparable to that of the IABP. Energetic results show a trend similar to the hemodynamic ones. The study will be continued by investigating other energetic variables and the autonomic response of the cardiovascular system.
Landesberg, Giora; Jaffe, Allan S; Gilon, Dan; Levin, Phillip D; Goodman, Sergey; Abu-Baih, Abed; Beeri, Ronen; Weissman, Charles; Sprung, Charles L; Landesberg, Amir
2014-04-01
Serum troponin concentrations predict mortality in almost every clinical setting they have been examined, including sepsis. However, the causes for troponin elevations in sepsis are poorly understood. We hypothesized that detailed investigation of myocardial dysfunction by echocardiography can provide insight into the possible causes of troponin elevation and its association with mortality in sepsis. Prospective, analytic cohort study. Tertiary academic institute. A cohort of ICU patients with severe sepsis or septic shock. Advanced echocardiography using global strain, strain-rate imaging and 3D left and right ventricular volume analyses in addition to the standard echocardiography, and concomitant high-sensitivity troponin-T measurement in patients with severe sepsis or septic shock. Two hundred twenty-five echocardiograms and concomitant high-sensitivity troponin-T measurements were performed in a cohort of 106 patients within the first days of severe sepsis or septic shock (2.1 ± 1.4 measurements/patient). Combining echocardiographic and clinical variables, left ventricular diastolic dysfunction defined as increased mitral E-to-strain-rate e'-wave ratio, right ventricular dilatation (increased right ventricular end-systolic volume index), high Acute Physiology and Chronic Health Evaluation-II score, and low glomerular filtration rate best correlated with elevated log-transformed concomitant high-sensitivity troponin-T concentrations (mixed linear model: t = 3.8, 3.3, 2.8, and -2.1 and p = 0.001, 0.0002, 0.006, and 0.007, respectively). Left ventricular systolic dysfunction determined by reduced strain-rate s'-wave or low ejection fraction did not significantly correlate with log(concomitant high-sensitivity troponin-T). Forty-one patients (39%) died in-hospital. Right ventricular end-systolic volume index and left ventricular strain-rate e'-wave predicted in-hospital mortality, independent of Acute Physiology and Chronic Health Evaluation-II score (logistic regression: Wald = 8.4, 6.6, and 9.8 and p = 0.004, 0.010, and 0.001, respectively). Concomitant high-sensitivity troponin-T predicted mortality in univariate analysis (Wald = 8.4; p = 0.004), but not when combined with right ventricular end-systolic volume index and strain-rate e'-wave in the multivariate analysis (Wald = 2.3, 4.6, and 6.2 and p = 0.13, 0.032, and 0.012, respectively). Left ventricular diastolic dysfunction and right ventricular dilatation are the echocardiographic variables correlating best with concomitant high-sensitivity troponin-T concentrations. Left ventricular diastolic and right ventricular systolic dysfunction seem to explain the association of troponin with mortality in severe sepsis and septic shock.
Mbaye, A; Dodo, B; Ngaïde, A A; Sy, N F; Babaka, K; Mingou, J S; Faye, M; Niang, K; Sarr, S A; Dioum, M; Bodian, M; Ndiaye, M B; Kane, A D; Ndour-Mbaye, M; Diao, M; Diack, B; Kane, M; Diagne-Sow, D; Thiaw, I; Kane, A
2017-09-01
To assess the prevalence of left ventricular hypertrophy according to electrocardiographic and echocardiographic criteria among hypertensive patients living in semi-rural Senegalese area. According to the World Health Organization STEPSwise approach, we conducted, in November 2012, a cross-sectional and exhaustive study in the population aged at least 35 years old and living for at least six months in the semi-rural area of Guéoul. We researched electrocardiographic and echocardiographic left ventricular hypertrophy in hypertensive subjects. Data were analyzed with SPSS 18.0 software version. The significance level was agreed for a value of P<0.05. We examined 1411 subjects aged on average of 48.5±12.7 years. In total, 654 subjects were hypertensive and screening of left ventricular hypertrophy (LVH) was effective in 515 of them. According to Sokolow-Lyon index, 86 subjects (16.7%) presented electrocardiographic LVH, more frequently in men (P=0.002). According to Cornell index and Cornell product, LVH was founded respectively in 66 (12.8%) and 52 subjects (10.1%), more frequently in female (P=0.0001; P=0.004). It was more common in grade 3 of hypertension however criteria. In echocardiography, prevalence of LVH was 2.2% (13 cases) according to the left ventricular mass, 9.3% (48 cases) according to the left ventricular mass indexed to body surface area and 8.2% (42 cases) according to the left ventricular mass indexed to height 2.7 . LVH was significantly correlated with the electrocardiographic LVH according to Sokolow-Lyon index (P<0.0001) and the grade 3 of hypertension (P=0.003). Although rare in hypertensive Senegalese living in semi-rural area, left ventricular hypertrophy is correlated with severity of grade of hypertension. Screening by electrocardiogram will allow better follow-up of these hypertensive subjects. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
de Oliveira, Luciano Fonseca Lemos; Romano, Minna Moreira Dias; de Carvalho, Eduardo Elias Vieira; Cabeza, Jorge Mejia; Salgado, Hélio Cesar; Fazan Júnior, Rubens; Costa, Renata Sesti; da Silva, João Santana; Higuchi, Maria de Lourdes; Maciel, Benedito Carlos; Cunha-Neto, Edécio; Marin-Neto, José Antônio; Simões, Marcus Vinícius
2016-01-21
Chronic Chagas cardiomyopathy in humans is characterized by segmental left ventricular wall motion abnormalities (WMA), mainly in the early stages of disease. This study aimed at investigating the detection of WMA and its correlation with the underlying histopathological changes in a chronic Chagas cardiomyopathy model in hamsters. Female Syrian hamsters (n=34) infected with 3.5×10(4) or 10(5) blood trypomastigote Trypanosoma cruzi (Y strain) forms and an uninfected control group (n=7) were investigated. After 6 or 10 months after the infection, the animals were submitted to in vivo evaluation of global and segmental left ventricular systolic function by echocardiography, followed by euthanasia and histological analysis for quantitative assessment of fibrosis and inflammation with tissue sampling in locations coinciding with the left ventricular wall segmentation employed at the in vivo echocardiographic evaluation. Ten of the 34 infected animals (29%) showed reduced left ventricular ejection fraction (<73%). Left ventricular ejection fraction was more negatively correlated with the intensity of inflammation (r=-0.63; P<0.0001) than with the extent of fibrosis (r=-0.36; P=0.036). Among the 24 animals with preserved left ventricular ejection fraction (82.9±5.5%), 8 (33%) showed segmental WMA predominating in the apical, inferior, and posterolateral segments. The segments exhibiting WMA, in comparison to those with normal wall motion, showed a greater extent of fibrosis (9.3±5.7% and 7±6.3%, P<0.0001) and an even greater intensity of inflammation (218.0±111.6 and 124.5±84.8 nuclei/mm², P<0.0001). Isolated WMA with preserved global systolic left ventricular function is frequently found in Syrian hamsters with experimental chronic Chagas cardiomyopathy whose underlying histopathological features are mainly inflammatory. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.
Hirayama, H; Sugano, M; Abe, N; Yonemoch, H; Makino, N
2001-01-01
Patients with NIDDM have excessive cardiovascular morbidity and mortality, even in the absence of hypertension. Left ventricular hypertrophy (LVH), which is an ominous prognostic sign and an independent risk factor for cardiac events, is often present in NIDDM patients. NIDDM male patients with (n=10) and without (n=12) hypertension, all of whom had been diagnosed over 10 years ago, were examined in the present study. Normotensive NIDDM patients had not received any anti-hypertensive drugs. All patients were classified according to the left ventricular mass (LVM) index by using M-mode echocardiography and were assessed regarding their systolic (fractional shortening) and diastolic function, which included the maximal early flow velocity (MFV), the mitral valve deceleration time (DT), and the isovolumic relaxation time (IRT) as determined by Doppler indices. Troglitazone (TRO), an antidiabetic drug, was administered to both groups at a dose of 400 mg/day for 6 months. After TRO treatment, a reduction in the LVM index and an improvement in the diastolic function were observed in the normotensive but not in the hypertensive patients. The TRO treatment was sensitive for cardiac regression in those normotensive patients. These results suggest that LVH and the diastolic function in NIDDM patients without hypertension may be associated with elevated insulin resistance because TRO has a pharmacological function to increase the insulin sensitivity and to decrease insulin resistance.
Salazar, J; Rivas, A; Rodriguez, M; Felipe, J; Garcia, M D; Bone, J
1994-01-01
Sixty-one children with insulin-dependent diabetes mellitus and twenty-three healthy subjects were investigated. The patients with diabetes mellitus aged 4 to 20 years (13.4 +/- 4.0) had had diabetes for 1 to 16 years (6.4 +/- 3.5). There were no cardiovascular risk factor other than diabetes. Patients received no medication other than insulin. The following echocardiographic and Doppler parameters of the left ventricle were analyzed in both groups: systolic and diastolic dimensions, systolic time intervals, fractional shortening, mean velocity of circumferential fiber shortening, percent relaxation of the left ventricular posterior wall at 50% of diastole, peak velocity of early (E) and late atrial (A) mitral flow. E/A ratio, deceleration of the E-wave, and the isovolumetric relaxation time. None of the parameters were significantly different between the groups. There was no relation observed between duration of diabetes and any of the parameters analyzed. It is concluded that there is not echocardiographic data to support the concept of diabetic cardiomyopathy in adolescents with type I (insulin-dependent) diabetes mellitus.
Stein, D G; Laks, H; Drinkwater, D C; Permut, L C; Louie, H W; Pearl, J M; George, B L; Williams, R G
1991-08-01
Total cavopulmonary connection was proposed as a modification of the Fontan procedure that might have greater benefits than previous methods. To assess this procedure we reviewed case histories of 38 patients (aged 17 months to 30 years) who underwent Fontan procedures with cavopulmonary anastomoses between January 1987 and December 1989. The group included 32 patients with univentricular heart, 2 with pulmonary atresia and intact ventricular septum, 3 with tricuspid atresia, and 1 with hypoplastic left heart syndrome. One or more previous palliative procedures were performed in 34 patients, including 19 systemic-pulmonary shunts, 16 pulmonary artery bandings, 7 atrial septectomies/septostomies, 7 Glenn shunts, and 1 patent ductus arteriosus ligation. Preoperative hemodynamics showed a pulmonary artery pressure of 12 mm Hg (range 6 to 22 mm Hg), pulmonary-systemic flow ratio of 1.6 (range 0.37 to 3.0), left ventricular end-diastolic pressure 9 mm Hg (range 3 to 15 mm Hg), and systemic arterial oxygen saturation of 82% (range 67% to 94%). Concomitant with cavopulmonary connection, 13 patients underwent additional procedures, including 9 atrioventricular valve annuloplasties, 4 Damus-Stansel-Kaye procedures, and 2 resections of subaortic membranes. Modifying the Fontan procedure in this fashion was particularly useful in the management of 2 patients with pulmonary atresia and intact ventricular septum who had right ventricular-dependent coronary blood flow. Cavopulmonary anastomosis and atrial septectomy were performed in both patients, with resultant inflow of oxygenated blood to the right ventricle and coronary arteries. Excellent postoperative results were noted in each. Postextubation hemodynamics for the entire group included a mean right atrial pressure of 13 mm Hg (range 11 to 17 mm Hg), a mean left atrial pressure of 6 mm Hg (range 3 to 12 mm Hg), and a room air oxygen saturation of 96% (range 92% to 98%). Seven patients had pleural effusions, 3 required postoperative pacemaker placement, and 2 required reoperation for tamponade. A venous assist device was required in one patient on the second postoperative day, but the patient was weaned successfully within 24 hours. One early death (2.6%) occurred in a patient who had intractable ventricular fibrillation 2 days after operation. There was one late cardiac death (2.7%) caused by ventricular failure and one late noncardiac death. These results demonstrate that total cavopulmonary connection provides excellent early definitive treatment, with low morbidity and mortality, for a variety of complex congenital heart lesions.
Spranger, Marty D.; Kaur, Jasdeep; Sala-Mercado, Javier A.; Krishnan, Abhinav C.; Abu-Hamdah, Rania; Alvarez, Alberto; Machado, Tiago M.; Augustyniak, Robert A.
2017-01-01
Increases in myocardial oxygen consumption during exercise mainly occur via increases in coronary blood flow (CBF) as cardiac oxygen extraction is high even at rest. However, sympathetic coronary constrictor tone can limit increases in CBF. Increased sympathetic nerve activity (SNA) during exercise likely occurs via the action of and interaction among activation of skeletal muscle afferents, central command, and resetting of the arterial baroreflex. As SNA is heightened even at rest in subjects with hypertension (HTN), we tested whether HTN causes exaggerated coronary vasoconstriction in canines during mild treadmill exercise with muscle metaboreflex activation (MMA; elicited by reducing hindlimb blood flow by ~60%) thereby limiting increases in CBF and ventricular performance. Experiments were repeated after α1-adrenergic blockade (prazosin; 75 µg/kg) and in the same animals following induction of HTN (modified Goldblatt 2K1C model). HTN increased mean arterial pressure from 97.1 ± 2.6 to 132.1 ± 5.6 mmHg at rest and MMA-induced increases in CBF, left ventricular dP/dtmax, and cardiac output were markedly reduced to only 32 ± 13, 26 ± 11, and 28 ± 12% of the changes observed in control. In HTN, α1-adrenergic blockade restored the coronary vasodilation and increased in ventricular function to the levels observed when normotensive. We conclude that exaggerated MMA-induced increases in SNA functionally vasoconstrict the coronary vasculature impairing increases in CBF, which limits oxygen delivery and ventricular performance in HTN. NEW & NOTEWORTHY We found that metaboreflex-induced increases in coronary blood flow and ventricular contractility are attenuated in hypertension. α1-Adrenergic blockade restored these parameters toward normal levels. These findings indicate that the primary mechanism mediating impaired metaboreflex-induced increases in ventricular function in hypertension is accentuated coronary vasoconstriction. Listen to this article’s corresponding podcast at http://ajpheart.podbean.com/e/metaboreflex-induced-functional-coronary-vasoconstriction/. PMID:27769997
Iida, Masato; Yamamoto, Mitsuru; Ishiguro, Yuko S; Yamazaki, Masatoshi; Ueda, Norihiro; Honjo, Haruo; Kamiya, Kaichirou
2014-01-01
Urinary type IV collagen is an early biomarker of diabetic nephropathy. Concomitant prediabetes (the early stage of diabetes) was associated with left ventricular (LV) diastolic dysfunction and increased brain natriuretic peptide (BNP) in hypertensive patients. We hypothesized that urinary type IV collagen may be related to these cardiac dysfunctions. We studied hypertensive patients with early prediabetes (HbA1c <5.7% and fasting glucose >110, n=18), those with prediabetes (HbA1c 5.7-6.4, n=98), and those with diabetes (HbA1c>6.5 or on diabetes medications, n=92). The participants underwent echocardiography to assess left atrial volume/body surface area (BSA) and the ratio of early mitral flow velocity to mitral annular velocity (E/e'). Left ventricular diastolic dysfunction (LVDD) was defined if patients had E/e'≥15, or E/e'=9-14 accompanied by left atrial volume/BSA≥32ml/mm(2). Urinary samples were collected for type IV collagen and albumin, and blood samples were taken for BNP and HbA1c. Urinary type IV collagen and albumin increased in parallel with the deterioration of glycemic status. In hypertensive patients with prediabetes, subjects with LVDD had higher levels of BNP and urinary type IV collagen than those without LVDD. In contrast, in hypertensive patients with diabetes, subjects with LVDD had higher urinary albumin and BNP than those without LVDD. Urinary type IV collagen correlated positively with BNP in hypertensive patients with prediabetes, whereas it correlated with HbA1c in those with diabetes. In hypertensive patients with prediabetes, urinary type IV collagen was associated with LV diastolic dysfunction and BNP. Copyright © 2014 Elsevier Inc. All rights reserved.
Jaroch, Joanna; Rzyczkowska, Barbara; Bociąga, Zbigniew; Vriz, Olga; Driussi, Caterina; Loboz-Rudnicka, Maria; Dudek, Krzysztof; Łoboz-Grudzień, Krystyna
2016-04-01
The contribution of arterial functional and structural changes to left ventricular (LV) diastolic dysfunction has been the area of recent research. There are some studies on the relationship between arterial stiffness (a.s.) and left atrial (LA) remodelling as a marker of diastolic burden. Little is known about the association of arterial structural changes and LA remodelling in hypertension (H). The aim of this study was to examine the relationship between carotid a.s. and intima-media thickness (IMT) and LA volume in subjects with H. The study included 245 previously untreated hypertensives (166 women and 79 men, mean age 53.7 ± 11.8 years). Each patient was subjected to echocardiography with measurement of LA volume, evaluation of left ventricular hypertrophy (LVH) and LV systolic/diastolic function indices, integrated assessment of carotid IMT and echo-tracking of a.s. and wave reflection parameters. Univariate regression analysis revealed significant correlations between indexed LA volume and selected clinical characteristics, echocardiographic indices of LVH and LV diastolic/systolic function and a.s./wave reflection parameters. The following parameters were identified as independent determinants of indexed LA volume on multivariate regression analysis: diastolic blood pressure (beta = -0.229, P < 0.001), left ventricular mass index (LVMI; beta = 0.258, P < 0.001), E/e’ index (ratio of early mitral flow wave velocity – E to early diastolic mitral annular velocity – e’; beta = 0.266, P = 0.001), augmentation index (AI; beta = 0.143, P = 0.008) and body mass index (BMI; beta = 0.132, P = 0.017). No correlations between indexed LA volume and IMT were found. There is a significant relationship between carotid arterial stiffness but not intima-media thickness and LA volume in patients with untreated hypertension.
Schmitz, Lothar; Stiller, Brigitte; Koch, Heike; Koehne, Petra; Lange, Peter
2004-02-01
In very low birth weight neonates, a left-to-right shunt via persistent ductus arteriosus (PDA) may interact with diastolic left ventricular function, but specific changes of Doppler parameters have yet to be reported. In a serial transmitral Doppler study, we investigated the impact of a PDA on diastolic function parameters. Twenty-two patients with and without PDA were examined on day 3.8+/-1 and day 14+/-2 after birth. By the first examination, 13 out of 22 patients had a PDA; by the second examination, the number was still 8 out of 22. Peak early and atrial flow velocities (44.8+/-15 and 50.1+/-13 cm/s, respectively) were higher (p<0.05) for neonates with PDA compared to those with closed duct (30.9+/-6 and 34.2 cm/s, respectively). Isovolumic relaxation time (IVRT) was shorter in neonates with PDA (45+/-7 ms, N=21) compared to those with a closed duct (55.3+/-5 ms, N=23) (p<0.01). IVRT correlated inversely with cardiac index (R=-0.79, p<0.01). All observed changes reversed to the normal range after closure of the PDA. When premature infants with a PDA experience a preload challenge, early and atrial peak velocities increase and IVRT shortens significantly. This coincidence of elevated transvalvular pressure differences and decreased IVRT in neonates with immature diastolic function can best be explained as a result of left atrial pressure elevation. Consequently, pulmonary venous pressure must be elevated, with its inherent effect on pulmonary capillary physiology. Thus, the monitoring of left ventricular diastolic function adds significant information to the care of preterm infants with a PDA.
Cor triatriatum sinister identified after new onset atrial fibrillation in an elderly man.
Zepeda, Ignacio A; Morcos, Peter; Castellanos, Luis R
2014-01-01
A 73-year-old man with new onset atrial fibrillation with rapid ventricular response underwent transthoracic echocardiography that revealed an echogenic linear structure along the left atrium, suggestive of cor triatriatum sinister (CTS). CTS was confirmed with transesophageal echocardiography which demonstrated a proximal accessory atrium receiving pulmonary venous flow separated from a distal true atrium by a fibromuscular membrane with a large fenestration allowing flow between the chambers. In CTS, the left atrium is divided into proximal and distal chambers by a fenestrated fibromuscular septum. This cardiac anomaly accounts for 0.1% of cases of congenital heart disease and rarely presents in adults. CTS is primarily diagnosed with echocardiography and is associated with left atrial enlargement and development of atrial fibrillation. Treatment options depend on size of the communication between proximal and distal chambers, the gradient across the membrane, and the position of pulmonary veins. In some instances, surgical resection of the membrane that divides the left atrium is warranted.
Cor Triatriatum Sinister Identified after New Onset Atrial Fibrillation in an Elderly Man
Zepeda, Ignacio A.; Morcos, Peter; Castellanos, Luis R.
2014-01-01
A 73-year-old man with new onset atrial fibrillation with rapid ventricular response underwent transthoracic echocardiography that revealed an echogenic linear structure along the left atrium, suggestive of cor triatriatum sinister (CTS). CTS was confirmed with transesophageal echocardiography which demonstrated a proximal accessory atrium receiving pulmonary venous flow separated from a distal true atrium by a fibromuscular membrane with a large fenestration allowing flow between the chambers. In CTS, the left atrium is divided into proximal and distal chambers by a fenestrated fibromuscular septum. This cardiac anomaly accounts for 0.1% of cases of congenital heart disease and rarely presents in adults. CTS is primarily diagnosed with echocardiography and is associated with left atrial enlargement and development of atrial fibrillation. Treatment options depend on size of the communication between proximal and distal chambers, the gradient across the membrane, and the position of pulmonary veins. In some instances, surgical resection of the membrane that divides the left atrium is warranted. PMID:25614746
Reference values of left heart echocardiographic dimensions and mass in male peri-pubertal athletes.
Cavarretta, Elena; Maffessanti, Francesco; Sperandii, Fabio; Guerra, Emanuele; Quaranta, Federico; Nigro, Antonia; Minati, Monia; Rebecchi, Marco; Fossati, Chiara; Calò, Leonardo; Pigozzi, Fabio
2018-01-01
Background Several articles have proposed reference values in healthy paediatric subjects, but none of them has evaluated a large population of healthy trained adolescents. Design The study purpose was to establish normal echocardiographic measurements of left heart (aortic root, left atrium and left ventricular dimensions and mass) in relation to age, weight, height, body mass index, body surface area and training hours in this specific population. Methods We retrospectively evaluated 2151 consecutive, healthy, peri-pubertal athletes (100% male, mean age 12.4 ± 1.4 years, range 8-18) referred to a single centre for pre-participation screening. All participants were young soccer athletes who trained for a mean of 7.2 ± 1.1 h per week. Results Left ventricular internal diameters, wall thickness, left ventricular mass, aortic root and left atrium diameters were significantly correlated to age, body surface area, height and weight ( p < 0.01). Age, height, weight and body surface area were found associated with chamber size, while body mass index and training hours were not. Inclusion of both age and body size parameters in the statistical models resulted in improved overall explained variance for diameters and left ventricular mass. Conclusion Equations, mean values and percentile charts for the different age groups may be useful as reference data in efficiently assessing left ventricular parameters in young athletes.
Cardiac structure and function in the obese: a cardiovascular magnetic resonance imaging study.
Danias, Peter G; Tritos, Nicholas A; Stuber, Matthias; Kissinger, Kraig V; Salton, Carol J; Manning, Warren J
2003-07-01
Obesity is a major health problem in the Western world. Among obese subjects cardiac pathology is common, but conventional noninvasive imaging modalities are often suboptimal for detailed evaluation of cardiac structure and function. We investigated whether cardiovascular magnetic resonance imaging (CMR) can better characterize possible cardiac abnormalities associated with obesity, in the absence of other confounding comorbidities. In this prospective cross-sectional study, CMR was used to quantify left and right ventricular volumes, ejection fraction, mass, cardiac output, and apical left ventricular rotation in 25 clinically healthy obese men and 25 age-matched lean controls. Obese subjects had higher left ventricular mass (203 +/- 38 g vs. 163 +/- 22 g, p < 0.001), end-diastolic volume (176 +/- 29 mL vs. 156 +/- 25 mL, p < 0.05), and cardiac output (8.2 +/- 1.2 L/min vs. 6.4 +/- 1.3 L/min, p < 0.001). The obese also had increased right ventricular mass (105 +/- 25 g vs. 87 +/- 18 g, p < 0.005) and end-diastolic volume (179 +/- 36 mL vs. 155 +/- 28 mL, p < 0.05). When indexed for height, differences in left and right ventricular mass, and left ventricular end-diastolic volume remained significant. Apical left ventricular rotation and rotational velocity patterns were also different between obese and lean subjects. Obesity is independently associated with remodeling of the heart. Cardiovascular magnetic resonance imaging identifies subtle cardiac abnormalities and may be the preferred imaging technique to evaluate cardiac structure and function in the obese.
Targeted deletion of apoptosis signal-regulating kinase 1 attenuates left ventricular remodeling
Yamaguchi, Osamu; Higuchi, Yoshiharu; Hirotani, Shinichi; Kashiwase, Kazunori; Nakayama, Hiroyuki; Hikoso, Shungo; Takeda, Toshihiro; Watanabe, Tetsuya; Asahi, Michio; Taniike, Masayuki; Matsumura, Yasushi; Tsujimoto, Ikuko; Hongo, Kenichi; Kusakari, Yoichiro; Kurihara, Satoshi; Nishida, Kazuhiko; Ichijo, Hidenori; Hori, Masatsugu; Otsu, Kinya
2003-01-01
Left ventricular remodeling that occurs after myocardial infarction (MI) and pressure overload is generally accepted as a determinant of the clinical course of heart failure. The molecular mechanism of this process, however, remains to be elucidated. Apoptosis signal-regulating kinase 1 (ASK1) is a mitogen-activated protein kinase kinase kinase that plays an important role in stress-induced apoptosis. We used ASK1 knockout mice (ASK-/-) to test the hypothesis that ASK1 is involved in development of left ventricular remodeling. ASK-/- hearts showed no morphological or histological defects. Echocardiography and cardiac catheterization revealed normal global structure and function. Left ventricular structural and functional remodeling were determined 4 weeks after coronary artery ligation or thoracic transverse aortic constriction (TAC). ASK-/- had significantly smaller increases in left ventricular end-diastolic and end-systolic ventricular dimensions and smaller decreases in fractional shortening in both experimental models compared with WT mice. The number of terminal deoxynucleotidyl transferase biotin-dUDP nick end-labeling-positive myocytes after MI or TAC was decreased in ASK-/- compared with that in WT mice. Overexpression of a constitutively active mutant of ASK1 induced apoptosis in isolated rat neonatal cardiomyocytes, whereas neonatal ASK-/- cardiomyocytes were resistant to H2O2-induced apoptosis. An in vitro kinase assay showed increased ASK1 activity in heart after MI or TAC in WT mice. Thus, ASK1 plays an important role in regulating left ventricular remodeling by promoting apoptosis. PMID:14665690
Apali, Zeynep; Bayata, Serdar; Yeşil, Murat; Arikan, Erdinç; Postaci, Nursen
2010-08-01
We aimed to investigate the effect of atrial pacing on left ventricular diastolic function and brain natriuretic peptide (BNP) levels in patients with DDD pacemaker. Thirty patients with complete atrio-ventricular (AV) block and DDD pacemaker were included. All patients had normal left ventricular systolic function. Echocardiographic diastolic function parameters (transmitral and tissue Doppler velocities during early (E and E') and late (A and A') filling) and NT-pro-BNP levels were evaluated prospectively during atrial sensing and pacing periods. Echocardiographic data were compared with paired sample t test and NT-pro-BNP levels were compared with Wilcoxon test. Echocardiographic E/A, E'/A', E/E' ratios were calculated as 0.72+/-0.34, 0.61+/-0.21 and 8.76+/-2.58 during atrial sensing period. Same parameters were found as 0.71+/-0.23, 0.64+/-0.16 and 8.93+/-3.16 respectively during atrial pacing period. Echocardiographic left ventricular diastolic function parameters were not significantly different during atrial pacing and atrial sensing periods. Median plasma NT-pro-BNP levels were measured as 142 pg/ml (min-max 47-563 pg/ml) and 147 pg/ml (min-max 33-1035 pg/ml) during atrial sensing and pacing periods respectively. These levels were not significantly different (p=0.86). The result of this study has shown that, atrial pacing has not any additional detrimental effect on left ventricular diastolic function parameters in paced patients with normal left ventricular systolic function.
Chasing the reflected wave back into the heart: a new hypothesis while the jury is still out
Codreanu, Ion; Robson, Matthew D; Rider, Oliver J; Pegg, Tammy J; Jung, Bernd A; Dasanu, Constantin A; Clarke, Kieran; Holloway, Cameron J
2011-01-01
Background: Arterial stiffness directly influences cardiac function and is independently associated with cardiovascular risk. However, the influence of the aortic reflected pulse pressure wave on left ventricular function has not been well characterized. The aim of this study was to obtain detailed information on regional ventricular wall motion patterns corresponding to the propagation of the reflected aortic wave on ventricular segments. Methods: Left ventricular wall motion was investigated in a group of healthy volunteers (n = 14, age 23 ± 3 years), using cardiac magnetic resonance navigator-gated tissue phase mapping. The left ventricle was divided into 16 segments and regional wall motion was studied in high temporal detail. Results: Corresponding to the expected timing of the reflected aortic wave reaching the left ventricle, a characteristic “notch” of regional myocardial motion was seen in all radial, circumferential, and longitudinal velocity graphs. This notch was particularly prominent in septal segments adjacent to the left ventricular outflow tract on radial velocity graphs and in anterior and posterior left ventricular segments on circumferential velocity graphs. Similarly, longitudinal velocity graphs demonstrated a brief deceleration in the upward recoil motion of the entire ventricle at the beginning of diastole. Conclusion: These results provide new insights into the possible influence of the reflected aortic waves on ventricular segments. Although the association with the reflected wave appears to us to be unambiguous, it represents a novel research concept, and further studies enabling the actual recording of the pulse wave are required. PMID:21731888
Ro, Richard; Halpern, Dan; Sahn, David J; Homel, Peter; Arabadjian, Milla; Lopresto, Charles; Sherrid, Mark V
2014-11-11
The hydrodynamic cause of systolic anterior motion of the mitral valve (SAM) is unresolved. This study hypothesized that echocardiographic vector flow mapping, a new echocardiographic technique, would provide insights into the cause of early SAM in obstructive hypertrophic cardiomyopathy (HCM). We analyzed the spatial relationship of left ventricular (LV) flow and the mitral valve leaflets (MVL) on 3-chamber vector flow mapping frames, and performed mitral valve measurements on 2-dimensional frames in patients with obstructive and nonobstructive HCM and in normal patients. We compared 82 patients (22 obstructive HCM, 23 nonobstructive HCM, and 37 normal) by measuring 164 LV pre- and post-SAM velocity vector flow maps, 82 maximum isovolumic vortices, and 328 2-dimensional frames. We observed color flow and velocity vector flow posterior to the MVL impacting them in the early systolic frames of 95% of obstructive HCM, 22% of nonobstructive HCM, and 11% of normal patients (p < 0.001). In both pre- and post-SAM frames, we measured a high angle of attack >60° of local vector flow onto the posterior surface of the leaflets whether the flow was ejection (59%) or the early systolic isovolumic vortex (41%). Ricochet of vector flow, rebounding off the leaflet into the cul-de-sac, was noted in 82% of the obstructed HCM, 9% of nonobstructive HCM, and none (0%) of the control patients (p < 0.001). Flow velocities in the LV outflow tract on the pre-SAM frame 1 and 2 mm from the tip of the anterior leaflet were low: 39 and 43 cm/s, respectively. Early systolic flow impacts the posterior surfaces of protruding MVL initiating SAM in obstructive HCM. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
[Acute left ventricular systolic dysfunction after pericardial effusion drainage].
Brauner, F B; Nunes, C E; Fabra, R; Riesgo, A; Thomé, L G
1997-12-01
A patient with a thymoma and initially normal ventricular systolic function developed cardiac tamponade, which was relieved by pericardiocentesis. After four days, the tumor was removed and, one week after the relief of tamponade, she developed severe left ventricular systolic dysfunction, that recovered in three days with venous therapy.
Right ventricular involvement in cardiac sarcoidosis demonstrated with cardiac magnetic resonance
van Geuns, Robert‐Jan; Ainslie, Gillian; Ector, Joris; Heidbuchel, Hein; Crijns, Harry J.G.M.
2017-01-01
Abstract Aims Cardiac involvement in sarcoidosis is reported in up to 30% of patients. Left ventricular involvement demonstrated by contrast‐enhanced cardiac magnetic resonance has been well validated. We sought to determine the prevalence and distribution of right ventricular late gadolinium enhancement in patients diagnosed with pulmonary sarcoidosis. Methods and results We prospectively evaluated 87 patients diagnosed with pulmonary sarcoidosis with contrast‐enhanced cardiac magnetic resonance for right ventricular involvement. Pulmonary artery pressures were non‐invasively evaluated with Doppler echocardiography. Patient characteristics were compared between the groups with and without right ventricular involvement, and right ventricular enhancement was correlated with pulmonary hypertension, ventricular mass, volume, and systolic function. Left ventricular late gadolinium enhancement was demonstrated in 30 patients (34%). Fourteen patients (16%) had right ventricular late gadolinium enhancement, with sole right ventricular enhancement in only two patients. The pattern of right ventricular enhancement consisted of right ventricular outflow tract enhancement in 1 patient, free wall enhancement in 8 patients, ventricular insertion point enhancement in 10 patients, and enhancement of the right side of the interventricular septum in 11 patients. Pulmonary arterial hypertension correlated with the presence of right ventricular enhancement (P < 0.001). Right ventricular enhancement correlated with systolic ventricular dysfunction (P < 0.001), hypertrophy (P = 0.001), and dilation (P < 0.001). Conclusions Right ventricular enhancement was present in 16% of patients diagnosed with pulmonary sarcoidosis and in 48% of patients with left ventricular enhancement. The presence of right ventricular enhancement correlated with pulmonary arterial hypertension, right ventricular systolic dysfunction, hypertrophy, and dilation. PMID:29154434
Hellman, Yaron; Malik, Adnan S; Lane, Kathleen A; Shen, Changyu; Wang, I-Wen; Wozniak, Thomas C; Hashmi, Zubair A; Munson, Sarah D; Pickrell, Jeanette; Caccamo, Marco A; Gradus-Pizlo, Irmina; Hadi, Azam
2017-05-01
Currently, blood pressure (BP) measurement is obtained noninvasively in patients with continuous flow left ventricular assist device (LVAD) by placing a Doppler probe over the brachial or radial artery with inflation and deflation of a manual BP cuff. We hypothesized that replacing the Doppler probe with a finger-based pulse oximeter can yield BP measurements similar to the Doppler derived mean arterial pressure (MAP). We conducted a prospective study consisting of patients with contemporary continuous flow LVADs. In a small pilot phase I inpatient study, we compared direct arterial line measurements with an automated blood pressure (ABP) cuff, Doppler and pulse oximeter derived MAP. Our main phase II study included LVAD outpatients with a comparison between Doppler, ABP, and pulse oximeter derived MAP. A total of five phase I and 36 phase II patients were recruited during February-June 2014. In phase I, the average MAP measured by pulse oximeter was closer to arterial line MAP rather than Doppler (P = 0.06) or ABP (P < 0.01). In phase II, pulse oximeter MAP (96.6 mm Hg) was significantly closer to Doppler MAP (96.5 mm Hg) when compared to ABP (82.1 mm Hg) (P = 0.0001). Pulse oximeter derived blood pressure measurement may be as reliable as Doppler in patients with continuous flow LVADs. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Kosaka, Ryo; Fukuda, Kyohei; Nishida, Masahiro; Maruyama, Osamu; Yamane, Takashi
2013-01-01
In order to monitor the condition of a patient using a left ventricular assist system (LVAS), blood flow should be measured. However, the reliable determination of blood-flow rate has not been established. The purpose of the present study is to develop a noninvasive blood-flow meter using a curved cannula with zero compensation for an axial flow blood pump. The flow meter uses the centrifugal force generated by the flow rate in the curved cannula. Two strain gauges served as sensors. The first gauges were attached to the curved area to measure static pressure and centrifugal force, and the second gauges were attached to straight area to measure static pressure. The flow rate was determined by the differences in output from the two gauges. The zero compensation was constructed based on the consideration that the flow rate could be estimated during the initial driving condition and the ventricular suction condition without using the flow meter. A mock circulation loop was constructed in order to evaluate the measurement performance of the developed flow meter with zero compensation. As a result, the zero compensation worked effectively for the initial calibration and the zero-drift of the measured flow rate. We confirmed that the developed flow meter using a curved cannula with zero compensation was able to accurately measure the flow rate continuously and noninvasively.
Management of pump thrombosis in patients with left ventricular assist devices.
Stulak, John M; Sharma, Shashank; Maltais, Simon
2015-04-01
The gradual evolution of left ventricular assist device (LVAD) therapy has resulted in a durable option for patients as either a bridge to transplantation (BTT) or a destination therapy (DT). Outcomes with current continuous-flow devices continue to demonstrate significant patient benefit, not only in enhanced survival but also in improved functional capacity and quality of life. While the lessening of adverse events through time has resulted in more widespread adoption of this therapy, there continues to be unintended consequences, including, most notably, infection, bleeding, and thrombosis. Beginning in 2011, centers and collaborative groups began to observe a significant increase in the incidence of pump thrombosis with the HeartMate II LVAD (Thoratec Corp., Pleasanton, CA, USA). However, this clinical scourge is not limited to the HeartMate II, as the HeartWare Ventricular Assist System (HVAD; HeartWare Inc., Framingham, MA, USA) has also had these same issues, which led to pump modifications and the appreciation of more strict control of blood pressure and anticoagulation with this pump design. We review the current status of the field of mechanical circulatory support in its approach to diagnosis, management, and prevention of LVAD pump thrombosis.
Ventricular tachycardia during arthroscopic shoulder surgery: a report of two cases.
Cho, Seung Hyun; Yi, Jin Woong; Kwack, Yoon Ho; Park, Sung Wook; Kim, Mi Kyeong; Rhee, Yong Girl
2010-03-01
We routinely have performed arthroscopic shoulder surgery under general anesthesia in the beach chair position using epinephrine (0.33 mg/L) saline irrigation. At a 2-week interval, two patients, a 19-year-old man scheduled to undergo an arthroscopic Bankart repair for left traumatic anterior instability and a 49-year-old woman scheduled for an arthroscopic rotator cuff repair for a left rotator cuff tear, were resuscitated by chest compression and defibrillation due to a sudden developed cardiogenic shock following ventricular tachycardia at the time of arthroscopic shoulder surgery. They were transferred to the intensive care unit because their emergent echocardiogram showed significantly decreased cardiac functions. They were fully recovered and then discharged. Epinephrine was considered to be the cause of ventricular tachycardia because the two patients showed no anaphylactic reaction to drugs or symptoms of air embolism related to the beach chair position. In addition, according to our observation of epinephrine flow patterns, it was more likely that highly concentrated epinephrine was rapidly infused into the body. This complication is very rare. However, thorough understanding of the side effects and their development of epinephrine during arthroscopic shoulder surgery should neither be overemphasized nor disregarded.
Prevalence and hemodynamic effects of leaning during CPR
Niles, Dana E.; Sutton, Robert M.; Nadkarni, Vinay M.; Glatz, Andrew; Zuercher, Mathias; Maltese, Matthew R.; Eilevstjønn, Joar; Abella, Benjamin S.; Becker, Lance B.; Berg, Robert A.
2013-01-01
Background Cardiopulmonary resuscitation (CPR) guidelines recommend complete release between chest compressions (CC). Objective Evaluate the hemodynamic effects of leaning (incomplete chest wall release) during CPR and the prevalence of leaning during CPR. Results In piglet ventricular fibrillation cardiac arrests, 10% and 20% (1.8 kg and 3.6 kg, respectively), leaning during CPR increased right atrial pressures, decreased coronary perfusion pressures, and decreased cardiac index and left ventricular myocardial blood flow by nearly 50%. In contrast, residual leaning of a 260 g accelerometer/ force feedback device did not adversely affect cardiac index or myocardial blood flow. Among 108 adult in-hospital CPR events, leaning ≥2.5 kg was demonstrable in 91% of the events and 12% of the evaluated CC. For 12 children with in-hospital CPR, 28% of CC had residual leaning ≥2.5 kg and 89% had residual leaning ≥0.5 kg. Conclusions Leaning during CPR increases intrathoracic pressure, decreases coronary perfusion pressure, and decreases cardiac output and myocardial blood flow. Leaning is common during CPR. PMID:22208173
DOE Office of Scientific and Technical Information (OSTI.GOV)
Botvinick, E.H.; Frais, M.A.; Shosa, D.W.
1982-08-01
The ability of scintigraphic phase image analysis to characterize patterns of abnormal ventricular activation was investigated. The pattern of phase distribution and sequential phase changes over both right and left ventricular regions of interest were evaluated in 16 patients with normal electrical activation and wall motion and compared with those in 8 patients with an artificial pacemaker and 4 patients with sinus rhythm with the Wolff-Parkinson-White syndrome and delta waves. Normally, the site of earliest phase angle was seen at the base of the interventricular septum, with sequential change affecting the body of the septum and the cardiac apex andmore » then spreading laterally to involve the body of both ventricles. The site of earliest phase angle was located at the apex of the right ventricle in seven patients with a right ventricular endocardial pacemaker and on the lateral left ventricular wall in one patient with a left ventricular epicardial pacemaker. In each case the site corresponded exactly to the position of the pacing electrode as seen on posteroanterior and left lateral chest X-ray films, and sequential phase changes spread from the initial focus to affect both ventricles. In each of the patients with the Wolff-Parkinson-White syndrome, the site of earliest ventricular phase angle was located, and it corresponded exactly to the site of the bypass tract as determined by endocardial mapping. In this way, four bypass pathways, two posterior left paraseptal, one left lateral and one right lateral, were correctly localized scintigraphically. On the basis of the sequence of mechanical contraction, phase image analysis provides an accurate noninvasive method of detecting abnormal foci of ventricular activation.« less
Smerup, Morten; Damkjær, Mads; Brøndum, Emil; Baandrup, Ulrik T; Kristiansen, Steen Buus; Nygaard, Hans; Funder, Jonas; Aalkjær, Christian; Sauer, Cathrine; Buchanan, Rasmus; Bertelsen, Mads Frost; Østergaard, Kristine; Grøndahl, Carsten; Candy, Geoffrey; Hasenkam, J Michael; Secher, Niels H; Bie, Peter; Wang, Tobias
2016-02-01
Giraffes--the tallest extant animals on Earth--are renowned for their high central arterial blood pressure, which is necessary to secure brain perfusion. Arterial pressure may exceed 300 mmHg and has historically been attributed to an exceptionally large heart. Recently, this has been refuted by several studies demonstrating that the mass of giraffe heart is similar to that of other mammals when expressed relative to body mass. It thus remains unexplained how the normal-sized giraffe heart generates such massive arterial pressures. We hypothesized that giraffe hearts have a small intraventricular cavity and a relatively thick ventricular wall, allowing for generation of high arterial pressures at normal left ventricular wall tension. In nine anaesthetized giraffes (495±38 kg), we determined in vivo ventricular dimensions using echocardiography along with intraventricular and aortic pressures to calculate left ventricular wall stress. Cardiac output was also determined by inert gas rebreathing to provide an additional and independent estimate of stroke volume. Echocardiography and inert gas-rebreathing yielded similar cardiac outputs of 16.1±2.5 and 16.4±1.4 l min(-1), respectively. End-diastolic and end-systolic volumes were 521±61 ml and 228±42 ml, respectively, yielding an ejection fraction of 56±4% and a stroke volume of 0.59 ml kg(-1). Left ventricular circumferential wall stress was 7.83±1.76 kPa. We conclude that, relative to body mass, a small left ventricular cavity and a low stroke volume characterizes the giraffe heart. The adaptations result in typical mammalian left ventricular wall tensions, but produce a lowered cardiac output. © 2016. Published by The Company of Biologists Ltd.
Atrial and ventricular function after cardioversion of atrial fibrillation.
Xiong, C.; Sonnhag, C.; Nylander, E.; Wranne, B.
1995-01-01
OBJECTIVE--Previous studies on atrial recovery after cardioversion of atrial fibrillation have not taken into account new knowledge about the pathophysiology of transmitral and transtricuspid flow velocity patterns. It is possible to shed further light on this problem if atrioventricular inflow velocity, venous filling pattern, and atrioventricular annulus motion are recorded and interpreted together. DESIGN--Prospective examinations of mitral and tricuspid transvalvar flow velocities, superior caval and pulmonary venous filling, and mitral and tricuspid annulus motion were recorded using Doppler echocardiography. Examinations were performed before and 24 hours, 1 month, and 20 months after cardioversion. SETTING--Tertiary referral centre for cardiac disease with facilities for invasive and non-invasive investigation. PATIENTS--16 patients undergoing cardioversion of atrial fibrillation in whom sinus rhythm had persisted for 24 hours or more. RESULTS--Before conversion there was no identifiable A wave in transvalvar flow recordings. The total motion of the tricuspid and mitral annulus was subnormal and there was no identifiable atrial component. Venous flow patterns in general showed a low systolic velocity. After conversion, A waves and atrial components were seen in all patients and increased significantly (P < 0.01) with time. There was a similar time course for the amplitude of annulus atrial components, an increased systolic component of venous inflow, an increased A wave velocity, and a decreased E/A ratio of the transvalvar velocity curves. The ventricular component of annulus motion was unchanged. Changes in general occurred earlier on the right side than the left. CONCLUSIONS--This study indicates that, in addition to the previously known electromechanical dissociation of atrial recovery that exists after cardioversion of atrial fibrillation, there may also be a transient deterioration of ventricular function modulating the transvalvar inflow velocity recordings. Function on the right side generally becomes normal earlier than on the left. Integration of information from transvalvar inflow curves, annulus motion, and venous filling patterns gives additional insight into cardiac function. PMID:7547019
Passive control of a biventricular assist device with compliant inflow cannulae.
Gregory, Shaun David; Pearcy, Mark John; Timms, Daniel
2012-08-01
Rotary ventricular assist device (VAD) support of the cardiovascular system is susceptible to suction events due to the limited preload sensitivity of these devices. This may be of particular concern with rotary biventricular support (BiVAD) where the native, flow balancing Starling response is diminished in both ventricles. The reliability of sensor and sensorless-based control systems which aim to control VAD flow based on preload has limitations, and, thus, an alternative solution is desired. This study introduces a compliant inflow cannula (CIC) which could improve the preload sensitivity of a rotary VAD by passively altering VAD flow depending on preload. To evaluate the design, both the CIC and a standard rigid inflow cannula were inserted into a mock circulation loop to enable biventricular heart failure support using configurations of atrial and ventricular inflow, and arterial outflow cannulation. A range of left (LVAD) and right VAD (RVAD) rotational speeds were tested as well as step changes in systemic/pulmonary vascular resistance to alter relative preloads, with resulting flow rates recorded. Simulated suction events were observed, particularly at higher VAD speeds, during support with the rigid inflow cannula, while the CIC prevented suction events under all circumstances. The compliant section passively restricted its internal diameter as preload was reduced, which increased the VAD circuit resistance and thus reduced VAD flow. Therefore, a CIC could potentially be used as a passive control system to prevent suction events in rotary left, right, and biventricular support. © 2012, Copyright the Authors. Artificial Organs © 2012, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Suárez, Carmen; Villar, José; Martel, Nieves; Extremera, Blas Gil; Suliman, Najaty; Campo, Carlos; Castellanos, Victoriano; Liébana, Antonio; Rodilla, Enrique; Nieto, Javier; Velasco, Olga; Ruilope, Luis M
2006-01-04
Left ventricular hypertrophy is an important predictor of cardiovascular risk and its detection contributes to risk stratification. However, echocardiography is not a routine procedure and electrocardiography (ECG) underestimates its prevalence. To evaluate the prevalence of echocardiographic left ventricular hypertrophy in low and medium risk non-treated hypertensive subjects, in order to find out the percentage of them who would be reclassified as high risk patients. Cross-sectional, multicenter study was performed in hospital located hypertension units. An echocardiogram was performed in 197 previously untreated hypertensive patients, > 18 years, classified as having low (61%) or medium (39%) risk, according to the OMS/ISH classification. The presence of left ventricular hypertrophy was considered if left ventricular mass index was > or = 134 or 110 g/m(2) in men and women, respectively (Devereux criteria). A logistic regression analysis was performed to identify factors associated to left ventricular hypertrophy. The prevalence of left ventricular hypertrophy was 23.9% (95% CI:17.9-29.9), 25.6% in men and 22.6% in women. In the low risk group its prevalence was 20.7% and in medium risk group 29.5%. Factors associated to left ventricular hypertrophy were: years since the diagnosis of hypertension, OR:1.1 (95% CI:1.003-1.227); systolic blood pressure, OR:1.08 (95% CI:1.029-1.138); diastolic blood pressure, OR:0.9 (95% CI:0.882-0.991); and family history of cardiovascular disease, OR:4.3 (95% CI:1.52-12.18). These findings underline the importance of performing an echocardiogram in low and high risk untreated hypertensive patients in which treatment would otherwise be delayed for even one year.
Samadov, Fuad; Yesildag, Osman; Sari, Ibrahim; Atas, Halil; Akhundova, Aysel; Basaran, Yelda
2017-06-01
Although numerous studies have shown the protective effects of the well-developed coronary collaterals on left ventricular functions, the relationship between collateral grade and left ventricular end diastolic pressure has not been studied in chronic total occlusion patients. Also, there are conflicting data on the effect of collaterals on NT-proBNP levels. The aim of our study was to evaluate the relationship between coronary collateral circulation and left ventricular end diastolic pressure and NT-proBNP levels in chronic total occlusion patients. Study group was retrospectively selected from the patients who had undergone coronary angiography at our hospital between June 2011 and March 2013. Clinical, biochemical, angiographic and hemodynamic data of 199 consecutive patients having at least one totally occluded major epicardial coronary artery were evaluated. Coronary collateral circulation was graded according to Rentrop classification. While Rentrop grade 3 was defined as well-developed, all the remaining collateral grades were regarded as poor collaterals. Overall 87 patients were found to have good collaterals and 112 patients had poor collaterals. There was no significant difference between the patients with well- or poorly developed coronary collaterals with regard to left ventricular end diastolic pressure (16.84 ± 5.40 mmHg vs 16.10 ± 6.09, respectively, p = 0,632) and log NT-proBNP (2.46 ± 0.58 vs 2.59 ± 0.76, respectively, p = 0,335). In patients with coronary chronic total occlusion even well-developed coronary collaterals are not capable of protecting the rise of left ventricular end diastolic pressure and NT-proBNP levels which are reliable markers of the left ventricular dysfunction.
Sedentary Screen Time and Left Ventricular Structure and Function: the CARDIA Study
Gibbs, Bethany Barone; Reis, Jared P.; Schelbert, Erik B.; Craft, Lynette L.; Sidney, Steve; Lima, Joao; Lewis, Cora E.
2013-01-01
Sedentary screen time (watching TV or using a computer) predicts cardiovascular outcomes independently from moderate and vigorous physical activity and could impact left ventricular structure and function through the adverse consequences of sedentary behavior. Purpose To determine whether sedentary screen time is associated with measures of left ventricular structure and function. Methods The Coronary Artery Risk Development in Young Adults (CARDIA) Study measured screen time by questionnaire and left ventricular structure and function by echocardiography in 2,854 black and white participants, aged 43–55 years, in 2010–2011. Generalized linear models evaluated cross-sectional trends for echocardiography measures across higher categories of screen time and adjusting for demographics, smoking, alcohol, and physical activity. Further models adjusted for potential intermediate factors (blood pressure, antihypertensive medication use, diabetes, and body mass index (BMI). Results The relationship between screen time and left ventricular mass(LVM) differed in blacks vs. whites. Among whites, higher screen time was associated with larger LVM (P<0.001), after adjustment for height, demographics, and lifestyle variables. Associations between screen time and LVM persisted when adjusting for blood pressure, antihypertensive medication use, and diabetes (P=0.008) but not with additional adjustment for BMI (P=0.503). Similar relationships were observed for screen time with LVM indexed to height2.7, relative wall thickness, and mass-to-volume ratio. Screen time was not associated with left ventricular structure among blacks or left ventricular function in either race group. Conclusions Sedentary screen time is associated with greater LVM in white adults and this relationship was largely explained by higher overall adiposity. The lack of association in blacks supports a potential qualitative difference in the cardiovascular consequences of sedentary screen-based behavior. PMID:23863618
Zou, Jun; Yu, Yi; Wu, Ping; Lin, Fu-Jun; Yao, Yao; Xie, Yun; Jiang, Geng-Ru
2016-10-15
Increasing evidence indicated that phosphorus emerged as an important cardiovascular risk factor in patients with chronic kidney disease (CKD). The fact that serum phosphorus was closely linked to vascular and valvar calcification may account for one important reason. However, left ventricular remodeling may also serve as another potential mechanism of the cardiac toxicity of phosphorus. In the present study, we evaluated the association of serum phosphorus with left ventricular remodeling. We investigated consecutive hospitalized patients with pre-dialysis CKD, who did not have symptomatic heart failure or take any phosphorus binder or calcitriol medications. Transthoracic echocardiography was applied to assess their left ventricular remodeling indices, both structural and functional. The 296 study subjects (mean age 56.4years) included 169 (57.1%) men, 203 (68.6%) hypertensive patients. In addition to gender, systolic blood pressure, and estimated glomerular filtration rate, serum phosphorus was an independent determinant of left ventricular mass index (LVMI, P=0.001). Similarly, serum phosphorus was also a determinant of left ventricular end diastolic dimension (P=0.0003), but not of relative wall thickness. In multivariate logistic analyses, serum phosphorus was significantly and independently associated with the prevalence of left ventricular hypertrophy (LVH, odds ratio [OR] 2.38 for each 1mmol/L increase, 95% CI 1.20-4.75, P=0.01). Moreover, the association was only confirmatory in eccentric LVH (OR 3.01, 95% CI 1.43-6.32, P=0.003) but not in concentric LVH (1.38, 95% CI, 0.54-3.49, P=0.50). Serum phosphorus was significantly and independently associated with LVMI and the prevalence of eccentric LVH in hospitalized patients with CKD. Copyright © 2016. Published by Elsevier Ireland Ltd.
Abramov, Dmitry; Haglund, Nicholas A; Di Salvo, Thomas G
2017-08-01
Although milrinone infusion is reported to benefit left ventricular function in chronic left heart failure, few insights exist regarding its effects on pulmonary circulation and right ventricular function. We retrospectively reviewed right heart catheterization data at baseline and during continuous infusion of milrinone in 69 patients with advanced heart failure and analyzed the effects on ventricular stroke work indices, pulmonary vascular resistance and pulmonary arterial compliance. Compared to baseline, milrinone infusion after a mean 58 ± 61 days improved mean left ventricular stroke work index (1540 ± 656 vs. 2079 ± 919 mmHg·mL/m 2 , p = 0.0007) to a much greater extent than right ventricular stroke work index (616 ± 346 vs. 654 ± 332, p = 0.053); however, patients with below median stroke work indices experienced a significant improvement in both left and right ventricular stroke work performance. Overall, milrinone reduced left and right ventricular filling pressures and pulmonary and systemic vascular resistance by approximately 20%. Despite an increase in pulmonary artery capacitance (2.3 ± 1.6 to 3.0 ± 2.0, p = 0.013) and a reduction in pulmonary vascular resistance (3.8 ± 2.3 to 3.0 ± 1.7 Wood units), milrinone did not reduce the transpulmonary gradient (13 ± 7 vs. 12 ± 6 mmHg, p = 0.252), the pulmonary artery pulse pressure (25 ± 10 vs. 24 ± 10, p = 0.64) or the pulmonary artery diastolic to pulmonary capillary wedge gradient (2.0 ± 6.5 vs. 2.4 ± 6.0, p = 0.353). Milrinone improved left ventricular stroke work indices to a greater extent than right ventricular stroke work indices and had beneficial effects on right ventricular net input impedance, predominantly via augmentation of left ventricular stroke volume and passive unloading of the pulmonary circuit. Patients who had the worst biventricular performance benefited the most from chronic milrinone infusion.
Pereira, Leila Maria Meirelles; Mandarim-de-Lacerda, Carlos Alberto
2001-01-01
Forty male Wistar rats were separated into four groups of ten rats each (control and other three groups that have received nitric oxide (NO) synthesis inhibitor L-NAME) but the last two groups have concomitantly received antihypertensive drugs (Enalapril and Verapamil). After 40 days of experimentation, the heart and the ventricles were measured. The optical disector was used for the calculation of numerical density of the cardiomyocytes (Nv[c]). The left ventricular myocytes number (N[c]) was calculated as the product of Nv[c] and the left ventricular myocardium volume (LVMV) that was determined by using the Scherle's method. In the L-NAME group the blood pressure (BP) had a significant weekly increment. In the enalapril and the verapamil groups, BP increased in the first two weeks, but decreased in the following weeks. The LVMV increased in the L-NAME rats and decreased in the enalapril and verapamil animals. The Nv[c] and N[c] decreased in the L-NAME rats but the verapamil and enalapril treatments maintained the Nv[c] close to the control group. In conclusion, the left ventricular hypertrophy and the significant decrease of the left ventricular cardiomyocyte number caused by the NO synthesis inhibition are efficiently prevented with the use of enalapril and verapamil. PMID:11454102
Polte, Christian L; Lagerstrand, Kerstin M; Gao, Sinsia A; Lamm, Carl R; Bech-Hanssen, Odd
2015-07-01
Two-dimensional echocardiography and real-time 3-D echocardiography have been reported to underestimate human left ventricular volumes significantly compared with cardiovascular magnetic resonance. We investigated the ability of 2-D echocardiography, real-time 3-D echocardiography and cardiovascular magnetic resonance to delineate dimensions of increasing complexity (diameter-area-volume) in a multimodality phantom model and in vivo, with the aim of elucidating the main cause of underestimation. All modalities were able to delineate phantom dimensions with high precision. In vivo, 2-D and real-time 3-D echocardiography underestimated short-axis end-diastolic linear and areal and all left ventricular volumetric dimensions significantly compared with cardiovascular magnetic resonance, but not short-axis end-systolic linear and areal dimensions. Underestimation increased successively from linear to volumetric left ventricular dimensions. When analyzed according to the same principles, 2-D and real-time 3-DE echocardiography provided similar left ventricular volumes. In conclusion, echocardiographic underestimation of left ventricular dimensions is due mainly to inherent technical differences in the ability to differentiate trabeculated from compact myocardium. Identical endocardial border definition criteria are needed to minimize differences between the modalities and to ensure better comparability in clinical practice. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Left ventricular hypertrophy: virtuous intentions, malign consequences.
Pokharel, Saraswati; Sharma, Umesh C; Pinto, Yigal M
2003-06-01
Left ventricular hypertrophy (LVH) is currently the focus of intense cardiovascular research, with the resultant rapid evolution of novel concepts relating to its exceedingly complex pathophysiology. In addition to the alterations in signal transduction and disturbances in Ca(2+) homeostasis, there are structural changes in myofilaments, disorganization of the cytoskeletal framework and increased collagen synthesis. LVH is associated with progressive left ventricular remodeling that culminates to heart failure. The modern treatment of left ventricular hypertrophy is now largely based on the hypothesis that neuroendocrine activation is important in the progression of the disease and inhibition of neurohormones is likely to have long-term benefit with regard to morbidity and mortality. Drugs specifically designed to unload the left ventricle, such as diuretics and vasodilators, appears to be less effective in reducing LV mass and improving prognosis. Thus, the evolution of treatment for LVH itself has provided much enlightenment for our understanding of the fundamental biology of the disorder.
NASA Astrophysics Data System (ADS)
Hirose, Junichi; Oshima, Tomomitsu; Fujimori, Yoshiharu; Uchida, Yasumi
1993-05-01
Recent advances in fiberoptic technology enabled us to observe percutaneously the cardiac chambers and valves. We examined left ventricular luminal and valvular changes by percutaneous fiberoptic angioscopy in patients with rheumatic valvular disease. Six patients with echocardiographic rheumatic changes in the mitral valves, underwent angioscopy during routine cardiac catheterization. The fiberscope 4.2 F in diameter, and the guiding catheter 9 F in external diameter with an inflatable balloon around the distal most tip were used for angioscopy. The left ventricular endocardial surface was diffusely white in color or white and brown in mosaic fashion. Echocardiography and angiography had low sensitivity for detecting the changes of the left ventricular luminal surface. Whitish changes which were observed by angioscopy were not related to the indices derived from echocardiography and angiography. The results indicate the possibility of percutaneous angioscopy in detecting left ventricular luminal changes in patients with rheumatic valvular disease.
M-Mode Echocardiographic Changes in Growing Beagles
Diez-Prieto, Inmaculada; García-Rodríguez, M Belén; Ríos-Granja, M Angeles; Cano-Rábano, María J; Peña-Penabad, Marina; Pérez-García, Carlos C
2010-01-01
Heart growth in 6 female beagle dogs was measured by using M-mode echocardiography at 4, 7, 10, 13, 17, and 21 mo of age. The same 6 dogs were evaluated throughout the study to establish when cardiac development ends in this breed. The following parameters were measured during systole and diastole: left ventricle posterior wall thickness, interventricular septal thickness, left ventricular internal dimension, left atrial dimension during ventricular systole, aortic root dimension at end diastole, E-point to septal separation, left ventricular preejection period, ejection time of the left ventricular outflow, and time between the cessation and onset of the mitral inflow intervals. The percentage of the left ventricle posterior wall thickening, fractional shortening, ejection fraction, left ventricular end systolic and end-diastolic volumes, ratio of the left atrial dimension to aortic root dimension, and the Tei index of myocardial performance were calculated. The heart rate was measured by cardiac auscultation. The influence of ageing on each echocardiographic parameter and relationships with body weight and surface were studied. Results show that cardiac development in female beagles can be considered finished by the age of 1 y, perhaps as soon as 7 mo. The cardiac indexes studied were unaffected by the age and corporal dimensions, confirming the usefulness of these parameters for evaluating cardiac functionality alterations independent of a dog's age and body weight or surface area. PMID:20122313
Haemodynamic and energetic properties of stunned myocardium in rabbit hearts.
Schipke, J. D.; Korbmacher, B.; Dorszewski, A.; Selcan, G.; Sunderdiek, U.; Arnold, G.
1996-01-01
OBJECTIVE--To amplify the description of myocardial stunning. DESIGN--Control versus 30 min after a 20 min no flow ischaemia. EXPERIMENTAL ANIMALS--15 isolated rabbit hearts perfused with erythrocyte suspension. MAIN OUTCOME MEASURES--Left ventricular systolic function in terms of aortic flow, peak systolic pressure (LVPmax), dP/dtmax, and the end systolic pressure-volume relation (ESPVR); early relaxation from dP/dtmin and rate of left ventricular pressure decay (tau). Passive properties: ventricular and myocardial stiffness. Coronary resistance from coronary blood flow and perfusion pressure. Total myocardial oxygen consumption (MVo2tot). Total mechanical energy via pressure-volume area (PVA). Contractile efficiency (Econ) and MVo2 of the unloaded contracting heart (MVo2unl). External mechanical efficiency (Eext) from stroke work and MVo2tot. RESULTS--Systolic variables in stunned myocardium were significantly decreased (mean (SD)): aortic flow: 38 (13) v 9 (11) ml/min; LVPmax: 112 (19) v 74 (18) mm Hg; dP/dtmax: 1475 (400) v 1075 (275) mm Hg/s. ESPVR was not significantly decreased, at 138 (73) v 125 (58) mm Hg/ml, but the volume axis intercept was shifted rightward: 0.30 (0.37) v 0.65 (0.25) ml. Likewise, early relaxation was impaired: dP/dtmin (-1275 (250) v -975 (250) mm Hg/s) and tau (37 (7) v 46 (10) ms). LVPed was significantly decreased at 19 (12) v 12 (7) mm Hg, and both the ventricular (end diastolic pressure-volume relation) and the myocardial stiffness (constant k) were increased by 75% and 31%, respectively. Coronary resistance increased non-significantly from 0.83 (0.31) to 1.04 (0.41) mm Hg/(ml/min/100 g). Decreases in PVA (570 (280) v 270 (200) mm Hg.ml/100 g), MVo2tot (40 (9) v 34 (8) microliters/beat/100 g), and MVo2unl (26 (9) v 22 (6) microliters/beat/100 g) did not reach significance, in contrast to significant decreases in Econ (31 (18) v 14 (7)%) and Eext (0.75 (0.29) v 0.18 (0.25) arbitrary units). CONCLUSIONS--Ventricular systolic function is decreased after brief episodes of ischaemia. The decrease in diastolic function probably amplifies the systolic deterioration during myocardial stunning. Passive diastolic properties are also changed, shown by increases in both ventricular and myocardial stiffness. The increase in coronary resistance indicates stunning at the vascular level which could limit oxygen supply. With maintained MVo2tot during stunning, external efficiency is decreased. Possible candidates for this metabolic stunning are inadequate excitation-contraction coupling and disturbed O2 utilisation by the contractile apparatus. Images PMID:8624873
Left ventricular assist device implantation via left thoracotomy: alternative to repeat sternotomy.
Pierson, Richard N; Howser, Renee; Donaldson, Terri; Merrill, Walter H; Dignan, Rebecca J; Drinkwater, Davis C; Christian, Karla G; Butler, Javed; Chomsky, Don; Wilson, John R; Clark, Rick; Davis, Stacy F
2002-03-01
Repeat sternotomy for left ventricular assist device insertion may result in injury to the right heart or patent coronary grafts, complicating intraoperative and postoperative management. In 4 critically ill patients, left thoracotomy was used as an alternative to repeat sternotomy. Anastomosis of the outflow conduit to the descending thoracic aorta provided satisfactory hemodynamic support.
Re-evaluation of hypoplastic left heart syndrome from a developmental and morphological perspective.
Crucean, A; Alqahtani, A; Barron, D J; Brawn, W J; Richardson, R V; O'Sullivan, J; Anderson, R H; Henderson, D J; Chaudhry, B
2017-08-10
Hypoplastic left heart syndrome (HLHS) covers a spectrum of rare congenital anomalies characterised by a non-apex forming left ventricle and stenosis/atresia of the mitral and aortic valves. Despite many studies, the causes of HLHS remain unclear and there are conflicting views regarding the role of flow, valvar or myocardial abnormalities in its pathogenesis, all of which were proposed prior to the description of the second heart field. Our aim was to re-evaluate the patterns of malformation in HLHS in relation to recognised cardiac progenitor populations, with a view to providing aetiologically useful sub-groupings for genomic studies. We examined 78 hearts previously classified as HLHS, with subtypes based on valve patency, and re-categorised them based on their objective ventricular phenotype. Three distinct subgroups could be identified: slit-like left ventricle (24%); miniaturised left ventricle (6%); and thickened left ventricle with endocardial fibroelastosis (EFE; 70%). Slit-like ventricles were always found in combination with aortic atresia and mitral atresia. Miniaturised left ventricles all had normally formed, though smaller aortic and mitral valves. The remaining group were found to have a range of aortic valve malformations associated with thickened left ventricular walls despite being described as either atresia or stenosis. The degree of myocardial thickening was not correlated to the degree of valvar stenosis. Lineage tracing in mice to investigate the progenitor populations that form the parts of the heart disrupted by HLHS showed that whereas Nkx2-5-Cre labelled myocardial and endothelial cells within the left and right ventricles, Mef2c-AHF-Cre, which labels second heart field-derived cells only, was largely restricted to the endocardium and myocardium of the right ventricle. However, like Nkx2-5-Cre, Mef2c-AHF-Cre lineage cells made a significant contribution to the aortic and mitral valves. In contrast, Wnt1-Cre made a major contribution only to the aortic valve. This suggests that discrete cardiac progenitors might be responsible for the patterns of defects observed in the distinct ventricular sub-groups. Only the slit-like ventricle grouping was found to map to the current nomenclature: the combination of mitral atresia with aortic atresia. It appears that slit-like and miniature ventricles also form discrete sub-groups. Thus, reclassification of HLHS into subgroups based on ventricular phenotype, might be useful in genetic and developmental studies in investigating the aetiology of this severe malformation syndrome.
Badar, Athar A; Brunton, Alan P T; Mahmood, Ammad H; Dobbin, Stephen; Pozzi, Andrea; McMinn, Jenna F; Sinclair, Andrew J E; Gardner, Roy S; Petrie, Mark C; Curry, Phil A; Al-Attar, Nawwar H K; Pettit, Stephen J
2015-01-01
A systematic search of Medline, EMBASE and CINAHL electronic databases was performed. Original research articles reporting all-cause mortality following surgery in patients with aortic regurgitation and severe left ventricular systolic dysfunction (LVSD) were identified. Nine of the 10 eligible studies were observational, single-center, retrospective analyses. Survival ranged from 86 to 100% at 30 days; 81 to 100% at 1 year and 68 to 84% at 5 years. Three studies described an improvement in mean left ventricular ejection fraction (LVEF) following aortic valve replacement (AVR) of 5-14%; a fourth study reported an increase in mean left ventricular ejection fraction (LVEF) of 9% in patients undergoing isolated AVR but not when AVR was combined with coronary artery bypass graft and/or mitral valve surgery. Three studies demonstrated improvements in functional New York Heart Association (NYHA) class following AVR. Additional studies are needed to clarify the benefits of AVR in patients with more extreme degrees of left ventricular systolic dysfunction (LVSD) and the potential roles of cardiac transplantation and transaortic valve implantation.
Amoogzar, Hamid; Shakiba, Ali Mohammad; Derakhshan, Dorna; Ajami, Gholamhossein; Cheriki, Sirous; Borzouee, Mohammad; Edraki, Mohammad Reza; Mehdizadegan, Nima
2015-01-01
The aim of this study was to evaluate the left ventricular systolic and diastolic function before and after transcatheter percutaneous patent ductus arteriosus (PDA) closure. 21 children (age >6 months old) diagnosed with hemodynamically significant PDA underwent percutaneous PDA closure. Conventional, Doppler and tissue Doppler imaging and speckled-derived strain rate echocardiography were done at pre-closure, 1 day (early) and 1 month (late) post-closure. Mean age of the patients (female/male: 1.3) was 17.54 ± 24.7 months with the mean PDA diameter of 3.6 ± 0.8 mm. Systolic measures (ejection fraction, shortening fraction) reduced significantly early after PDA closure (P < 0.05). After 1 month, both improved significantly; ultimately, after 1 month no change was observed in systolic function measures compared with the pre-closure status. Early and late diastolic flow velocities of mitral (E M and A M) reduced considerably in early and late post-closure time (P < 0.05). Both early tissue Doppler early velocity of lateral mitral annulus (E'M) and early to late velocity ratio (E'M/A'M) of lateral mitral annulus decreased significantly (P = 0.02) in early post-closure. After 1 month, E'M increased considerably. (P = 0.01) but E'M/A'M had an insignificant rise (P > 0.05). E M/E'M ratio did not change in early post-closure but it had a considerable reduction in the subsequent month compared with the pre- and early post-closure (P < 0.001 for both occasions). Global and segmental longitudinal strain measures reduced significantly early after PDA closure (P < 0.05) but it improved remarkably in the subsequent month. Transcatheter PDA closure causes a significant decrease in left ventricular performance early after PDA closure which recovers completely within 1 month. Also PDA size can affect post-closure left ventricular function.
Ghandi, Yazdan; Habibi, Danial; Nasri, Khadijeh; Alinejad, Saeed; Taherahmad, Hassan; Arjmand Shabestari, Ali; Nematinejad, Ali
2018-06-17
There are some evidences supporting the relation between gestational diabetes mellitus (GDM) and diastolic dysfunction. The aim of our study was to investigate the effect of well-controlled GDM on morphological and functional myocardium. We designed a prospective cross-sectional study to evaluate left ventricular (LV) diastolic function of 60 neonates born from mothers with well-controlled GDM (case group) on days of 3-5 after birth. The infants of diabetic mothers (IDM) group were divided into two groups: diabetic mothers treated only with diet (class A) and group of mothers on medical therapy by insulin or metformin (class B). Traditional echocardiography and pulsed-wave Doppler (PWD), tissue Doppler imaging (TDI) were performed for all the neonates. The study group consisted of 60 neonates as males (M) = 32, (0.53%) and females (F) = 28, (0.46%). Using M-mode echocardiography, interventricular septum thickness (IVS), and LV mass were significantly higher in IDM than control group (p = .0001). The PWD showed both a significantly more peak mitral flow at early diastolic wave (E) and an early filling deceleration time (E-DT) (p = .0001). Tissue Doppler echocardiography parameters A' (cm/s) (p = .0001), E' (cm/s) (p = .002), and E'/A' ratio (p = .0001), left ventricular myocardial performance index (LVMPI), and isovolumetric relaxation time (IVRT) were outstandingly different between the two groups (p = .0001, respectively). Evaluating the GDM group mothers of class A and class B, no significant difference was noted in PWD or TDI parameters compared with the healthy ones. It seems that neonates of mothers with well-controlled GDM are still at increased risk of cardiac hypertrophy, subclinical diastolic dysfunction, and impaired left ventricular relaxation. This can be interpreted that focusing only on glycemic control is not enough to prevent cardiac dysfunction.
Coronary wave energy: a novel predictor of functional recovery after myocardial infarction.
De Silva, Kalpa; Foster, Paul; Guilcher, Antoine; Bandara, Asela; Jogiya, Roy; Lockie, Tim; Chowiencyzk, Phil; Nagel, Eike; Marber, Michael; Redwood, Simon; Plein, Sven; Perera, Divaka
2013-04-01
Revascularization after acute coronary syndromes provides prognostic benefit, provided that the subtended myocardium is viable. The microcirculation and contractility of the subtended myocardium affect propagation of coronary flow, which can be characterized by wave intensity analysis. The study objective was to determine in acute coronary syndromes whether early wave intensity analysis-derived microcirculatory (backward) expansion wave energy predicts late viability, defined by functional recovery. Thirty-one patients (58±11 years) were enrolled after non-ST elevation myocardial infarction. Regional left ventricular function and late-gadolinium enhancement were assessed by cardiac magnetic resonance imaging, before and 3 months after revascularization. The backward-traveling (microcirculatory) expansion wave was derived from wave intensity analysis of phasic coronary pressure and velocity in the infarct-related artery, whereas mean values were used to calculate hyperemic microvascular resistance. Twelve-hour troponin T, left ventricular ejection fraction, and percentage late-gadolinium enhancement mass were 1.35±1.21 µg/L, 56±11%, and 8.4±6.0%, respectively. The infarct-related artery backward-traveling (microcirculatory) expansion wave was inversely correlated with late-gadolinium enhancement infarct mass (r=-0.81; P<0.0001) and strongly predicted regional left ventricular recovery (r=0.68; P=0.001). By receiver operating characteristic analysis, a backward-traveling (microcirculatory) expansion wave threshold of 2.8 W m(-2) s(-2)×10(5) predicted functional recovery with sensitivity and specificity of 0.91 and 0.82 (AUC 0.88). Hyperemic microvascular resistance correlated with late-gadolinium enhancement mass (r=0.48; P=0.03) but not left ventricular recovery (r=-0.34; P=0.07). The microcirculation-derived backward expansion wave is a new index that correlates with the magnitude and location of infarction, which may allow for the prediction of functional myocardial recovery. Coronary wave intensity analysis may facilitate myocardial viability assessment during cardiac catheterization.
Acute microcirculatory response to nicotine in frog web.
Horimoto, M; Koyama, T
1982-01-01
Acute effects of nicotine (NC) on the microcirculation of frog webs were studied by measuring the blood flow velocity in arterioles, and by determining the diameter of both arterioles and venules. Simultaneous recordings of the ventricular pressure and heart rate were obtained in order to compute the vascular resistance and to interpret the changes in microcirculation. The web of right hindlimb was immersed in a solution of NC (2.6 to 3.4 mg/ml) for 4 min. Blood flow velocity in web arterioles of left hindlimb was measured by means of a laser Doppler microscope. Internal diameters of web microvessels were determined using a micrometer on the ocular lens of the microscope. Mean flow velocity (MV) and pulsatile amplitude (PA) were calculated from the pulsatile flow-velocity contour for each vessel. Both MV and PA were increased after the immersion of the web in NC solution. Although the magnitude of the increment in MV was proportional to that in ventricular pressure, the vasodilation of both arterioles and venules and the flow rate in arterioles higher than the initial state continued even after the ventricular pressure had returned to the initial control value. Calculation of the relative change in vascular resistance in web arterioles following NC administration suggested a vasodilator response to NC. Furthermore, our results indicate that sufficient NC can be absorbed across the web epithelium to produce a systemic vascular response when the concentration of NC in the bathing solution is 2.6 mg/ml.
Endurance sport and "cardiac injury": a prospective study of recreational ironman athletes.
Leischik, Roman; Spelsberg, Norman
2014-09-03
Participation in triathlon competitions has increased in recent years. Many studies have described left or right ventricular injury in endurance athletes. The goal of this study was to examine the right and left ventricular cardiac structures and function and dynamic cardio-pulmonary performance in a large cohort of middle- and long-distance triathletes. 87 triathletes (54 male and 33 female) were examined using spiroergometry and echocardiography. The inclusion criterion was participation in at least one middle- or long distance triathlon. Male triathletes showed a maximum oxygen absorption of 58.1 ± 8.6 mL/min/kg (female triathletes 52.8 ± 5.7 mL/min/kg), maximum ergometer performance of 347.8 ± 49.9 W (female triathletes 264.5 ± 26.1 W). Left ventricular ejection fraction (EF) was normal (male triathletes EF: 61.9% ± 3%, female triathletes EF: 63.0% ± 2.7%) and systolic right ventricular area change fraction (RV AFC%) showed normal values (males RV AFC%: 33.5% ± 2.2%, females 32.2% ± 2.8%). Doppler indices of diastolic function were normal in both groups. With respect to the echocardiographic readings the left ventricular mass for males and females were 217.7 ± 41.6 g and 145.9 ± 31.3 g, respectively. The relative wall thickness for males was 0.50 ± 0.07, whereas it was 0.47 ± 0.09 for females. The probability of left ventricular mass >220 g increased with higher blood pressure during exercise (OR: 1.027, CI 1.002-1.052, p = 0.034) or with higher training volume (OR: 1.23, CI 1.04-1.47, p = 0.019). Right or left ventricular dysfunction could not be found, although the maximal participation in triathlon competitions was 29 years. A left ventricular mass >220 g is more likely to occur with higher arterial pressure during exercise and with a higher training volume.
Endurance Sport and “Cardiac Injury”: A Prospective Study of Recreational Ironman Athletes
Leischik, Roman; Spelsberg, Norman
2014-01-01
Background: Participation in triathlon competitions has increased in recent years. Many studies have described left or right ventricular injury in endurance athletes. The goal of this study was to examine the right and left ventricular cardiac structures and function and dynamic cardio-pulmonary performance in a large cohort of middle- and long-distance triathletes. Methods: 87 triathletes (54 male and 33 female) were examined using spiroergometry and echocardiography. The inclusion criterion was participation in at least one middle- or long distance triathlon. Results: Male triathletes showed a maximum oxygen absorption of 58.1 ± 8.6 mL/min/kg (female triathletes 52.8 ± 5.7 mL/min/kg), maximum ergometer performance of 347.8 ± 49.9 W (female triathletes 264.5 ± 26.1 W). Left ventricular ejection fraction (EF) was normal (male triathletes EF: 61.9% ± 3%, female triathletes EF: 63.0% ± 2.7%) and systolic right ventricular area change fraction (RV AFC%) showed normal values (males RV AFC%: 33.5% ± 2.2%, females 32.2% ± 2.8%). Doppler indices of diastolic function were normal in both groups. With respect to the echocardiographic readings the left ventricular mass for males and females were 217.7 ± 41.6 g and 145.9 ± 31.3 g, respectively. The relative wall thickness for males was 0.50 ± 0.07, whereas it was 0.47 ± 0.09 for females. The probability of left ventricular mass >220 g increased with higher blood pressure during exercise (OR: 1.027, CI 1.002–1.052, p = 0.034) or with higher training volume (OR: 1.23, CI 1.04–1.47, p = 0.019). Conclusions: Right or left ventricular dysfunction could not be found, although the maximal participation in triathlon competitions was 29 years. A left ventricular mass >220 g is more likely to occur with higher arterial pressure during exercise and with a higher training volume. PMID:25192145
Zito, Concetta; Mohammed, Moemen; Todaro, Maria Chiara; Khandheria, Bijoy K; Cusmà-Piccione, Maurizio; Oreto, Giuseppe; Pugliatti, Pietro; Abusalima, Mohamed; Antonini-Canterin, Francesco; Vriz, Olga; Carerj, Scipione
2014-11-01
We evaluated the interplay between left ventricular diastolic function and large-artery stiffness in asymptomatic patients at increased risk of heart failure and no structural heart disease (Stage A). We divided 127 consecutive patients (mean age 49 ± 17 years) with risk factors for heart failure who were referred to our laboratory to rule out structural heart disease into two groups according to presence (Group 1, n = 35) or absence (Group 2, n = 92) of grade I left ventricular diastolic dysfunction. Doppler imaging with high-resolution echo-tracking software was used to measure intima-media thickness (IMT) and stiffness of carotid arteries. Group 1 had significantly higher mean age, blood pressure, left ventricular mass index, carotid IMT and arterial stiffness than Group 2 (P < 0.05). Overall, carotid stiffness indices (β-stiffness index, augmentation index and elastic modulus) and 'one-point' pulse wave velocity each showed inverse correlation with E-wave velocity, E' velocity and E/A ratio, and direct correlation with A-wave velocity, E-wave deceleration time and E/E' ratio (P < 0.05). Arterial compliance showed negative correlations with the echocardiographic indices of left ventricular diastolic function (P < 0.05). On logistic regression analysis, age, hypertension, SBP, pulse pressure, left ventricular mass index, carotid IMT and stiffness parameters were associated with grade I left ventricular diastolic dysfunction (P < 0.05 for each). However, on multivariate logistic analysis, only 'one-point' pulse wave velocity and age were independent predictors (P = 0.038 and P = 0.016, respectively). An independent association between grade I left ventricular diastolic dysfunction and increased arterial stiffness is demonstrated at the earliest stage of heart failure. Hence, assessment of vascular function, beyond cardiac function, should be included in a comprehensive clinical evaluation of these patients.
Mitov, Vladimir M; Perisic, Zoran; Jolic, Aleksandar; Kostic, Tomislav; Aleksic, Aleksandar; Aleksic, Zeljka
2016-07-01
The study was aimed at assessing the difference between the right ventricle apex versus the right ventricular outflow tract lead position in functional capacity in the patients with the preserved left ventricular ejection fraction after 12 months of pacemaker stimulation. This was a prospective, randomized, follow-up study, which lasted for 12 months. The study sample included 132 consecutive patients who were implanted with permanent anti-bradicardiac pacemaker. Regarding the right ventricular lead position the patients were divided into two groups: the right ventricle apex group consisting of 61 patients with right ventricular apex lead position. The right ventricular outflow tract group included 71 patients with right ventricular outflow tract lead position. Functional capacity was assessed by Minnesota Living With Heart Failure score, New York Heart Association class and Six Minute Walk Test. Left ventricular ejection fraction was assessed by echocardiography. Minnesota Living With Heart Failure score and New York Heart Association class had a statistically significant improvement in both study groups. The patients from right ventricle apex group walked 20.95% (p=O.03) more in comparison to starting values. The patients from right ventricular outflow tract group walked only 13.63% (p=0.09) longer distance than the startingoneConclusion. Analysis of tests of functional status New York Heart Association class and Minnesota Living With Heart Failure questionnaire showed an even improvement in the right ventricle apex and right ventricular outflow tract groups. Analysis of 6 minute walk test showed that only the patients with the preserved left ventricular ejection fraction from the right ventricle apex group had a significant improvement after 12 months of pacemaker stimulation..