Method and device for determining heats of combustion of gaseous hydrocarbons
NASA Technical Reports Server (NTRS)
Singh, Jag J. (Inventor); Sprinkle, Danny R. (Inventor); Puster, Richard L. (Inventor)
1988-01-01
A method and device is provided for a quick, accurate and on-line determination of heats of combustion of gaseous hydrocarbons. First, the amount of oxygen in the carrier air stream is sensed by an oxygen sensing system. Second, three individual volumetric flow rates of oxygen, carrier stream air, and hydrocrabon test gas are introduced into a burner. The hydrocarbon test gas is fed into the burner at a volumetric flow rate, n, measured by a flowmeter. Third, the amount of oxygen in the resulting combustion products is sensed by an oxygen sensing system. Fourth, the volumetric flow rate of oxygen is adjusted until the amount of oxygen in the combustion product equals the amount of oxygen previously sensed in the carrier air stream. This equalizing volumetric flow rate is m and is measured by a flowmeter. The heat of combustion of the hydrocrabon test gas is then determined from the ratio m/n.
Engelen, Lina; de Wijk, Rene A; Prinz, Jon F; van der Bilt, Andries; Bosman, Frits
2003-01-01
Salivary flow rates were measured at rest and after three types of stimulation; odor, Parafilm chewing, and citric acid. The highest flow rate was elicited by citric acid followed by Parafilm and odor, while the lowest flow rate was unstimulated. In order to investigate whether and how the amount of saliva a subject produces influences the sensory ratings, the four types of salivary flow rates were correlated with sensory ratings of three different types of vanilla custard dessert. No significant correlation could be found between any of the salivary flow rates and the sensory ratings. A subject with a larger saliva flow rate during eating did not rate the foods differently from a subject with less saliva flow. The same pattern was seen for all types of stimulation. This finding could indicate that subjects are used to their respective amounts of saliva to such a degree that the differences in sensory ratings between subjects cannot be explained by the interindividual difference in saliva flow rate.
Packet Scheduling Mechanism to Improve Quality of Short Flows and Low-Rate Flows
NASA Astrophysics Data System (ADS)
Yokota, Kenji; Asaka, Takuya; Takahashi, Tatsuro
In recent years elephant flows are increasing by expansion of peer-to-peer (P2P) applications on the Internet. As a result, bandwidth is occupied by specific users triggering unfair resource allocation. The main packet-scheduling mechanism currently employed is first-in first-out (FIFO) where the available bandwidth of short flows is limited by elephant flows. Least attained service (LAS), which decides transfer priority of packets by the total amount of transferred data in all flows, was proposed to solve this problem. However, routers with LAS limit flows with large amount of transferred data even if they are low-rate. Therefore, it is necessary to improve the quality of low-rate flows with long holding times such as voice over Internet protocol (VoIP) applications. This paper proposes rate-based priority control (RBPC), which calculates the flow rate and control the priority by using it. Our proposed method can transfer short flows and low-rate flows in advance. Moreover, its fair performance is shown through simulations.
Koltun, G.F.
2013-01-01
This report presents the results of a study to assess potential water availability from the Atwood, Leesville, and Tappan Lakes, located within the Muskingum River Watershed, Ohio. The assessment was based on the criterion that water withdrawals should not appreciably affect maintenance of recreation-season pool levels in current use. To facilitate and simplify the assessment, it was assumed that historical lake operations were successful in maintaining seasonal pool levels, and that any discharges from lakes constituted either water that was discharged to prevent exceeding seasonal pool levels or discharges intended to meet minimum in-stream flow targets downstream from the lakes. It further was assumed that the volume of water discharged in excess of the minimum in-stream flow target is available for use without negatively impacting seasonal pool levels or downstream water uses and that all or part of it is subject to withdrawal. Historical daily outflow data for the lakes were used to determine the quantity of water that potentially could be withdrawn and the resulting quantity of water that would flow downstream (referred to as “flow-by”) on a daily basis as a function of all combinations of three hypothetical target minimum flow-by amounts (1, 2, and 3 times current minimum in-stream flow targets) and three pumping capacities (1, 2, and 3 million gallons per day). Using both U.S. Geological Survey streamgage data and lake-outflow data provided by the U.S. Army Corps of Engineers resulted in analytical periods ranging from 51 calendar years for the Atwood Lake to 73 calendar years for the Leesville and Tappan Lakes. The observed outflow time series and the computed time series of daily flow-by amounts and potential withdrawals were analyzed to compute and report order statistics (95th, 75th, 50th, 25th, 10th, and 5th percentiles) and means for the analytical period, in aggregate, and broken down by calendar month. In addition, surplus-water mass curve data were tabulated for each of the lakes. Monthly order statistics of computed withdrawals indicated that, for the three pumping capacities considered, increasing the target minimum flow-by amount tended to reduce the amount of water that can be withdrawn. The reduction was greatest in the lower percentiles of withdrawal; however, increasing the flow-by amount had no impact on potential withdrawals during high flow. In addition, for a given target minimum flow-by amount, increasing the pumping rate increased the total amount of water that could be withdrawn; however, that increase was less than a direct multiple of the increase in pumping rate for most flow statistics. Potential monthly withdrawals were observed to be more variable and more limited in some calendar months than others. Monthly order statistics and means of computed daily mean flow-by amounts indicated that flow-by amounts generally tended to be lowest during June–October and February. Increasing the target minimum flow-by amount for a given pumping rate resulted in some small increases in the magnitudes of the mean and 50th percentile and lower order statistics of computed mean flow-by, but had no effect on the magnitudes of the higher percentile statistics. Increasing the pumping rate for a given target minimum flow-by amount resulted in decreases in magnitudes of higher-percentile flow-by statistics by an amount equal to the flow equivalent of the increase in pumping rate; however, some lower percentile statistics remained unchanged.
Fodder Resource Uses and Assessment of Nitrogen Flows on Livestock Farming with Crop Production
NASA Astrophysics Data System (ADS)
Shirahase, Kyoko; Kobayashi, Hisashi
With understanding the livestock farming on cattle breeding practiced increasing of self-production of fodders by the farmland's operation as “Livestock Farming with crop production”, we investigated the utilizations of actual fodder resources and farmland for two selected different types of livestock farming systems: “Multiple Type” which practices cattle raising with fodder cultivation, and “Grazing Type” which practices grazing and fodder cultivation with similar feed self-sufficiency rates. We also prepared and compared material and nitrogen flow of both livestock farming systems. The amount of nitrogen flow is clearly different between the two types though feed self-sufficiency rates are at similar level. Moreover, we defined “Internal Nitrogen Rate (INR)” which indicates the rate of internal nitrogen use to total nitrogen use in cattle raising, “Internal Nitrogen Circulation Rate (NCR)” which indicates the ratio of nitrogen amount in internal circulation to the nitrogen amount introduced from outside, and Nitrogen Outflow Potential (Op), which is the balance of nitrogen amount between input to farmlands and uptake by plants, and analyzed the balance of the amounts of nitrogen flows in both livestock farming type. It is suggested that “Grazing type”, which had the values of relatively high NCR and absolutely low Op, was the livestock farming type with high rates of nitrogen procurement from the interregional farming and low risk of nitrogen outflow.
Koltun, G.F.
2014-01-01
This report presents the results of a study to assess potential water availability from the Charles Mill, Clendening, Piedmont, Pleasant Hill, Senecaville, and Wills Creek Lakes, located within the Muskingum River Watershed, Ohio. The assessment was based on the criterion that water withdrawals should not appreciably affect maintenance of recreation-season pool levels in current use. To facilitate and simplify the assessment, it was assumed that historical lake operations were successful in maintaining seasonal pool levels, and that any discharges from lakes constituted either water that was discharged to prevent exceeding seasonal pool levels or discharges intended to meet minimum in-stream flow targets downstream from the lakes. It further was assumed that the volume of water discharged in excess of the minimum in-stream flow target is available for use without negatively impacting seasonal pool levels or downstream water uses and that all or part of it is subject to withdrawal. Historical daily outflow data for the lakes were used to determine the quantity of water that potentially could be withdrawn and the resulting quantity of water that would flow downstream (referred to as “flow-by”) on a daily basis as a function of all combinations of three hypothetical target minimum flow-by amounts (1, 2, and 3 times current minimum in-stream flow targets) and three pumping capacities (1, 2, and 3 million gallons per day). Using both U.S. Geological Survey streamgage data (where available) and lake-outflow data provided by the U.S. Army Corps of Engineers resulted in analytical periods ranging from 51 calendar years for Charles Mill, Clendening, and Piedmont Lakes to 74 calendar years for Pleasant Hill, Senecaville, and Wills Creek Lakes. The observed outflow time series and the computed time series of daily flow-by amounts and potential withdrawals were analyzed to compute and report order statistics (95th, 75th, 50th, 25th, 10th, and 5th percentiles) and means for the analytical period, in aggregate, and broken down by calendar month. In addition, surplus-water mass curve data were tabulated for each of the lakes. Monthly order statistics of computed withdrawals indicated that, for the three pumping capacities considered, increasing the target minimum flow-by amount tended to reduce the amount of water that can be withdrawn. The reduction was greatest in the lower percentiles of withdrawal; however, increasing the flow-by amount had no impact on potential withdrawals during high flow. In addition, for a given target minimum flow-by amount, increasing the pumping rate typically increased the total amount of water that could be withdrawn; however, that increase was less than a direct multiple of the increase in pumping rate for most flow statistics. Potential monthly withdrawals were observed to be more variable and more limited in some calendar months than others. Monthly order statistics and means of computed daily mean flow-by amounts indicated that flow-by amounts generally tended to be lowest during June–October. Increasing the target minimum flow-by amount for a given pumping rate resulted in some small increases in the magnitudes of the mean and 50th percentile and lower order statistics of computed mean flow-by, but had no effect on the magnitudes of the higher percentile statistics. Increasing the pumping rate for a given target minimum flow-by amount resulted in decreases in magnitudes of higher-percentile flow-by statistics by an amount equal to the flow equivalent of the increase in pumping rate; however, some lower percentile statistics remained unchanged.
Yang, Ze-min; Chen, Long-hui; Lin, Jing; Zhang, Min; Yang, Xiao-rong; Chen, Wei-wen
2015-02-01
To compare the effect of citric acid stimulation on salivary alpha-amylase (sAA), total protein (TP), salivary flow rate, and pH value between Pi deficiency (PD) children and healthy children, thereby providing evidence for Pi controlling saliva theory. Twenty PD children were recruited, and 29 healthy children were also recruited at the same time. Saliva samples from all subjects were collected before and after citric acid stimulation. The sAA activity and amount, TP contents, salivary flow rate, and pH value were determined and compared. (1) Citric acid stimulation was able to significantly increase salivary flow rate, pH value, sAA activities, sAA specific activity and sAA amount (including glycosylated and non-glycosylated sAA amount) in healthy children (P<0.05), while it could markedly increase salivary flow rate, pH value, and glycosylated sAA levels in PD children (P<0.05); (2) Although there was no statistical difference in determined salivary indices between the two groups (P>0.05), salivary indices except salivary flow rate and glycosylated sAA levels decreased more in PD children. There was statistical difference in sAA activity ratio, sAA specific activity ratio, and the ratio of glycosylated sAA levels between PD children and healthy children (P<0.05). PD children had decreased response to citric acid stimulation.
Gallegos-Infante, José-Alberto; Rocha-Guzman, Nuria-Elizabeth; González-Laredo, Ruben-Francisco; Reynoso-Camacho, Rosalia; Medina-Torres, Luis; Cervantes-Cardozo, Veronica
2009-01-01
The interest in nopal has encouraged the use of dehydration; there are few studies about the effect of process parameters on the nopal polyphenol content and antioxidant activity. The objective of the present work was to evaluate the effect of air-drying flow rates on the amount and antioxidant capacity of extracts of Opuntia ficus indica cladodes. Nopal was dried at 45 degrees C and air flow rates of 3 and 5 m/sec. Samples were analyzed for moisture, total polyphenol, flavonoid, and flavonol contents, chain-breaking activity, inhibition of low-density lipoprotein and deoxyribose oxidation. Nopal drying at an air flow rate of 3 m/sec showed higher values of phenols, flavonoids and flavonols. The best value of low-density lipoprotein inhibition and deoxyribose was found at 1,000 microg/ml. The air flow rate affected the amount of polyphenols and the OH( . ) radical scavenging, but did not modify the chain-breaking activity and the low-density lipoprotein inhibition activity.
Instability patterns in a miscible core annular flow
NASA Astrophysics Data System (ADS)
D'Olce, Marguerite; Martin, Jerome; Rakotomalala, Nicole; Salin, Dominique; Talon, Laurent
2006-11-01
Laboratoire FAST, batiment 502, campus universitaire, 91405 Orsay Cedex (France). Experiments are performed with two miscible fluids of equal density but different viscosities. The fluids are injected co-currently and concentrically into a cylindrical pipe. The so-obtained base state is an axisymmetric parallel flow, for which the ratio of the flow rates of the two fluids monitors the relative amount (and so the radius) of the fluids. Depending on this relative amount and on the total flow rate of the fluids, unstable axisymmetric patterns such as mushrooms and pearls are observed. We delineate the diagram of occurrence of the two patterns and characterize the instabilities.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Buecker, Arno; Neuerburg, Joerg; Schmitz-Rode, Thomas
1997-11-15
Purpose: To evaluate the feasibility of thrombus removal from temporary vena cava filters using a rheolytic thrombectomy device and to assess the embolization rate of this procedure. Methods: Five temporary vena cava filters together with porcine thrombi were placed in a vena cava flow model (semitranslucent silicone tube of 23 mm diameter, pulsatile flow at a mean flow rate of 4 L/min). A rheolytic thrombectomy system (Hydrolyser) was used with a 9 Fr guiding catheter to remove the clots. The effluent was passed through filters of different size and the amount of embolized particles as well as the remaining thrombusmore » were measured. Results: Thrombus removal rates ranged from 85% to 100%. Embolization rates between 47% and 60% were calculated for the different filters. Conclusion: The Hydrolyser is able to remove sufficiently high amounts of thrombus from temporary vena cava filters. However, the amount of embolized particles makes it impossible to utilize this method without special precautions against embolization.« less
Nofoam System Technology for Aircraft Hangar Fire Suppression Foam System
2011-07-01
use of a firefighting agent that meets Military Specification MIL - F - 24385 [Reference 2]. Significant amounts of AFFF wastewater is generated...rates, Table 3, were the established baseline for comparison. Table 3 theoretical flow rates were derived from Military Specification MIL - F - 24385 [Reference...flow rates, Table 3, was the established baseline for comparison. Table 3 theoretical flow rates were derived from Military Specification MIL - F - 24385 [Reference
Re-injection feasibility study of fracturing flow-back fluid in shale gas mining
NASA Astrophysics Data System (ADS)
Kang, Dingyu; Xue, Chen; Chen, Xinjian; Du, Jiajia; Shi, Shengwei; Qu, Chengtun; Yu, Tao
2018-02-01
Fracturing flow-back fluid in shale gas mining is usually treated by re-injecting into formation. After treatment, the fracturing flow-back fluid is injected back into the formation. In order to ensure that it will not cause too much damage to the bottom layer, feasibility evaluations of re-injection of two kinds of fracturing fluid with different salinity were researched. The experimental research of the compatibility of mixed water samples based on the static simulation method was conducted. Through the analysis of ion concentration, the amount of scale buildup and clay swelling rate, the feasibility of re-injection of different fracturing fluid were studied. The result shows that the swelling of the clay expansion rate of treated fracturing fluid is lower than the mixed water of treated fracturing fluid and the distilled water, indicating that in terms of clay expansion rate, the treated fracturing flow-back fluid is better than that of water injection after re-injection. In the compatibility test, the maximum amount of fouling in the Yangzhou oilfield is 12mg/L, and the maximum value of calcium loss rate is 1.47%, indicating that the compatibility is good. For the fracturing fluid with high salinity in the Yanchang oilfield, the maximum amount of scaling is 72mg/L, and the maximum calcium loss rate is 3.50%, indicating that the compatibility is better.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jablonská, Jana, E-mail: jana.jablonska@vsb.cz; Kozubková, Milada, E-mail: milada.kozubkova@vsb.cz
Cavitation today is a very important problem that is solved by means of experimental and mathematical methods. The article deals with the generation of cavitation in convergent divergent nozzle of rectangular cross section. Measurement of pressure, flow rate, temperature, amount of dissolved air in the liquid and visualization of cavitation area using high-speed camera was performed for different flow rates. The measurement results were generalized by dimensionless analysis, which allows easy detection of cavitation in the nozzle. For numerical simulation the multiphase mathematical model of cavitation consisting of water and vapor was created. During verification the disagreement with the measurementsmore » for higher flow rates was proved, therefore the model was extended to multiphase mathematical model (water, vapor and air), due to release of dissolved air. For the mathematical modeling the multiphase turbulence RNG k-ε model for low Reynolds number flow with vapor and air cavitation was used. Subsequently the sizes of the cavitation area were verified. In article the inlet pressure and loss coefficient depending on the amount of air added to the mathematical model are evaluated. On the basis of the approach it may be create a methodology to estimate the amount of released air added at the inlet to the modeled area.« less
Improving the desulfurization performance of CaCO3 with sodium humate
NASA Astrophysics Data System (ADS)
Feng, Run; Sun, Zhiguo; Zhang, Wenqing; Huang, Hao; Hu, Haihang; Zhang, Li; Xie, Hongyong
2018-02-01
The influence of these factors on desulphurization efficiency was studied by changing the amount of calcium carbonate, the concentration of sulfur dioxide, the liquid flow rate of absorbent and the air flow rate, the optimum working condition was determined by the research of limestone-gypsum desulphurization process commonly used in industry. By changing the amount of calcium carbonate, we conclude that the volume of water in the desulfurization efficiency does not increase with the adding amount of calcium carbonate. The optimum conditions were determined : at the condicion of the concentration of 500ppm of sulfur dioxide, 10g calcium carbonate, 150L/h liquid flow and the minimum air flow rate of 6.75m3/h, the highest desulfurization efficiency was close to 100% when sodium humate was not added, but the holding time was only about 5 minutes. After adding 3g of humic acid, the desulfurization efficiency was improved obviously, and the instantaneous efficiency of 100% lasting for about 40 minutes. It can be seen that, calcium carbonate in the addition of humic acid sodium can significantly improve the absorption of calcium carbonate performance of SO2.
Development of a Small Area Sniffer
NASA Technical Reports Server (NTRS)
Meade, Laurie A.
1995-01-01
The aim of this project is to develop and implement a sniffer that is capable of measuring the mass flow rate of air through a small area of pinholes whose diameters are on the magnitude of thousandths of an inch. The sniffer is used to scan a strip of a leading edge panel, which is being used in a hybrid laminar flow control experiment, in order to survey the variations in the amount of air that passes through the porous surface at different locations. Spanwise scans are taken at different chord locations by increasing the pressure in a control volume that is connected to the sniffer head, and recording the drop in pressure as the air is allowed to flow through the tiny holes. This information is used to obtain the mass flow through the structure. More importantly, the deviations from the mean flow rate are found and used to determine whether there are any significant variations in the flow rate from one area to the next. The preliminary results show little deviation in the spanwise direction. These results are important when dealing with the location and amount of suction that will be applied to the leading edge in the active laminar flow control experiment.
NASA Astrophysics Data System (ADS)
ten Veldhuis, Marie-Claire; Schleiss, Marc
2017-04-01
In this study, we introduced an alternative approach for analysis of hydrological flow time series, using an adaptive sampling framework based on inter-amount times (IATs). The main difference with conventional flow time series is the rate at which low and high flows are sampled: the unit of analysis for IATs is a fixed flow amount, instead of a fixed time window. We analysed statistical distributions of flows and IATs across a wide range of sampling scales to investigate sensitivity of statistical properties such as quantiles, variance, skewness, scaling parameters and flashiness indicators to the sampling scale. We did this based on streamflow time series for 17 (semi)urbanised basins in North Carolina, US, ranging from 13 km2 to 238 km2 in size. Results showed that adaptive sampling of flow time series based on inter-amounts leads to a more balanced representation of low flow and peak flow values in the statistical distribution. While conventional sampling gives a lot of weight to low flows, as these are most ubiquitous in flow time series, IAT sampling gives relatively more weight to high flow values, when given flow amounts are accumulated in shorter time. As a consequence, IAT sampling gives more information about the tail of the distribution associated with high flows, while conventional sampling gives relatively more information about low flow periods. We will present results of statistical analyses across a range of subdaily to seasonal scales and will highlight some interesting insights that can be derived from IAT statistics with respect to basin flashiness and impact urbanisation on hydrological response.
DOT National Transportation Integrated Search
1971-07-01
The problem of displaying visibility information to both : controller and pilot is discussed in the context of visibility : information flow in the airport-aircraft system. : The optimum amount of visibility information, as well as its : rate of flow...
Identification of Carbon loss in the production of pilot-scale Carbon nanotube using gauze reactor
NASA Astrophysics Data System (ADS)
Wulan, P. P. D. K.; Purwanto, W. W.; Yeni, N.; Lestari, Y. D.
2018-03-01
Carbon loss more than 65% was the major obstacles in the Carbon Nanotube (CNT) production using gauze pilot scale reactor. The results showed that the initial carbon loss calculation is 27.64%. The calculation of carbon loss, then, takes place with various corrections parameters of: product flow rate error measurement, feed flow rate changes, gas product composition by Gas Chromatography Flame Ionization Detector (GC FID), and the carbon particulate by glass fiber filters. Error of product flow rate due to the measurement with bubble soap gives calculation error of carbon loss for about ± 4.14%. Changes in the feed flow rate due to CNT growth in the reactor reduce carbon loss by 4.97%. The detection of secondary hydrocarbon with GC FID during CNT production process reduces carbon loss by 5.14%. Particulates carried by product stream are very few and merely correct the carbon loss about 0.05%. Taking all the factors into account, the amount of carbon loss within this study is (17.21 ± 4.14)%. Assuming that 4.14% of carbon loss is due to the error measurement of product flow rate, the amount of carbon loss is 13.07%. It means that more than 57% of carbon loss within this study is identified.
Fuel thermal stability effects on spray characteristics
NASA Technical Reports Server (NTRS)
Lefebvre, A. H.; Nickolaus, D.
1987-01-01
The propensity of a heated hydrocarbon fuel toward solids deposition within a fuel injector is investigated experimentally. Fuel is arranged to flow through the injector at constant temperature, pressure, and flow rate and the pressure drop across the nozzle is monitored to provide an indication of the amount of deposition. After deposits have formed, the nozzle is removed from the test rig and its spray performance is compared with its performance before deposition. The spray characteristics measured include mean drop size, drop-size distribution, and radial and circumferential fuel distribution. It is found that small amounts of deposition can produce severe distortion of the fuel spray pattern. More extensive deposition restores spray uniformity, but the nozzle flow rate is seriously curtailed.
Investigation of operating parameters on CO2 splitting by dielectric barrier discharge plasma
NASA Astrophysics Data System (ADS)
Pan, CHEN; Jun, SHEN; Tangchun, RAN; Tao, YANG; Yongxiang, YIN
2017-12-01
Experiments of CO2 splitting by dielectric barrier discharge (DBD) plasma were carried out, and the influence of CO2 flow rate, plasma power, discharge voltage, discharge frequency on CO2 conversion and process energy efficiency were investigated. It was shown that the absolute quantity of CO2 decomposed was only proportional to the amount of conductive electrons across the discharge gap, and the electron amount was proportional to the discharge power; the energy efficiency of CO2 conversion was almost a constant at a lower level, which was limited by CO2 inherent discharge character that determined a constant gap electric field strength. This was the main reason why CO2 conversion rate decreased as the CO2 flow rate increase and process energy efficiency was decreased a little as applied frequency increased. Therefore, one can improve the CO2 conversion by less feed flow rate or larger discharge power in DBD plasma, but the energy efficiency is difficult to improve.
NASA Technical Reports Server (NTRS)
Chinitz, W.
1986-01-01
A computationally-viable model describing the interaction between fluid-mechanical turbulence and finite-rate combustion reactions, principally in high-speed flows was developed. Chemical kinetic mechanisms, complete and global, were developed describing the finite rate reaction of fuels of interest to NASA. These fuels included principally hydrogen and silane, although a limited amount of work involved hydrocarbon fuels as well.
Method and apparatus for controlling fluid flow
Miller, J.R.
1980-06-27
A method and apparatus for precisely controlling the rate (and hence amount) of fluid flow are given. The controlled flow rate is finely adjustable, can be extremely small (on the order of microliter-atmospheres per second), can be adjusted to zero (flow stopped), and is stable to better than 1% with time. The dead volume of the valve can be made arbitrarily small, in fact essentially zero. The valve employs no wearing mechanical parts (including springs, stems, or seals). The valve is finely adjustable, has a flow rate dynamic range of many decades, can be made compatible with any fluid, and is suitable for incorporation into an open or closed loop servo-control system.
O'Shaughnessy, P T; Hemenway, D R
2000-10-01
Trials were conducted to determine those factors that affect the accuracy of a direct-reading aerosol photometer when automatically controlling airflow rate within an exposure chamber to regulate airborne dust concentrations. Photometer response was affected by a shift in the aerosol size distribution caused by changes in chamber flow rate. In addition to a dilution effect, flow rate also determined the relative amount of aerosol lost to sedimentation within the chamber. Additional calculations were added to a computer control algorithm to compensate for these effects when attempting to automatically regulate flow based on a proportional-integral-derivative (PID) feedback control algorithm. A comparison between PID-controlled trials and those performed with a constant generator output rate and dilution-air flow rate demonstrated that there was no significant decrease in photometer accuracy despite the many changes in flow rate produced when using PID control. Likewise, the PID-controlled trials produced chamber aerosol concentrations within 1% of a desired level.
Plocková, J; Chmelík, J
2001-05-25
Gravitational field-flow fractionation (GFFF) utilizes the Earth's gravitational field as an external force that causes the settlement of particles towards the channel accumulation wall. Hydrodynamic lift forces oppose this action by elevating particles away from the channel accumulation wall. These two counteracting forces enable modulation of the resulting force field acting on particles in GFFF. In this work, force-field programming based on modulating the magnitude of hydrodynamic lift forces was implemented via changes of flow-rate, which was accomplished by a programmable pump. Several flow-rate gradients (step gradients, linear gradients, parabolic, and combined gradients) were tested and evaluated as tools for optimization of the separation of a silica gel particle mixture. The influence of increasing amount of sample injected on the peak resolution under flow-rate gradient conditions was also investigated. This is the first time that flow-rate gradients have been implemented for programming of the resulting force field acting on particles in GFFF.
Milk Flow Rates from bottle nipples used after hospital discharge.
Pados, Britt Frisk; Park, Jinhee; Thoyre, Suzanne M; Estrem, Hayley; Nix, W Brant
To test the milk flow rates and variability in flow rates of bottle nipples used after hospital discharge. Twenty-six nipple types that represented 15 common brands as well as variety in price per nipple and store location sold (e.g., Babies R' Us, Walmart, Dollar Store) were chosen for testing. Ten of each nipple type (n = 260 total) were tested by measuring the amount of infant formula expressed in 1 minute using a breast pump. Mean milk flow rate (mL/min) and coefficient of variation (CV) were calculated. Flow rates of nipples within brand were compared statistically. Milk flow rates varied from 1.68 mL/min for the Avent Natural Newborn Flow to 85.34 mL/min for the Dr. Brown's Standard Y-cut. Variability between nipple types also varied widely, from .03 for the Dr. Brown's Standard Level 3 to .37 for MAM Nipple 1 Slow Flow. The extreme range of milk flow rates found may be significant for medically fragile infants being discharged home who are continuing to develop oral feeding skills. The name of the nipple does not provide clear information about the flow rate to guide parents in decision making. Variability in flow rates within nipples of the same type may complicate oral feeding for the medically fragile infant who may not be able to adapt easily to change in flow rates. Both flow rate and variability should be considered when guiding parents to a nipple choice.
Isothermal evaporation of ethanol in a dynamic gas atmosphere.
Milev, Adriyan S; Wilson, Michael A; Kannangara, G S Kamali; Feng, Hai; Newman, Phillip A
2012-01-12
Optimization of evaporation and pyrolysis conditions for ethanol are important in carbon nanotube (CNT) synthesis. The activation enthalpy (ΔH(‡)), the activation entropy (ΔS(‡)), and the free energy barrier (ΔG(‡)) to evaporation have been determined by measuring the molar coefficient of evaporation, k(evap), at nine different temperatures (30-70 °C) and four gas flow rates (25-200 mL/min) using nitrogen and argon as carrier gases. At 70 °C in argon, the effect of the gas flow rate on k(evap) and ΔG(‡) is small. However, this is not true at temperatures as low as 30 °C, where the increase of the gas flow rate from 25 to 200 mL/min results in a nearly 6 times increase of k(evap) and decrease of ΔG(‡) by ~5 kJ/mol. Therefore, at 30 °C, the effect of the gas flow rate on the ethanol evaporation rate is attributed to interactions of ethanol with argon molecules. This is supported by simultaneous infrared spectroscopic analysis of the evolved vapors, which demonstrates the presence of different amounts of linear and cyclic hydrogen bonded ethanol aggregates. While the amount of these aggregates at 30 °C depends upon the gas flow rate, no such dependence was observed during evaporation at 70 °C. When the evaporation was carried out in nitrogen, ΔG(‡) was almost independent of the evaporation temperature (30-70 °C) and the gas flow rate (25-200 mL/min). Thus the evaporation of ethanol in a dynamic gas atmosphere at different temperatures may go via different mechanisms depending on the nature of the carrier gas.
Storage capacity in hot dry rock reservoirs
Brown, D.W.
1997-11-11
A method is described for extracting thermal energy, in a cyclic manner, from geologic strata which may be termed hot dry rock. A reservoir comprised of hot fractured rock is established and water or other liquid is passed through the reservoir. The water is heated by the hot rock, recovered from the reservoir, cooled by extraction of heat by means of heat exchange apparatus on the surface, and then re-injected into the reservoir to be heated again. Water is added to the reservoir by means of an injection well and recovered from the reservoir by means of a production well. Water is continuously provided to the reservoir and continuously withdrawn from the reservoir at two different flow rates, a base rate and a peak rate. Increasing water flow from the base rate to the peak rate is accomplished by rapidly decreasing backpressure at the outlet of the production well in order to meet periodic needs for amounts of thermal energy greater than a baseload amount, such as to generate additional electric power to meet peak demands. The rate of flow of water provided to the hot dry rock reservoir is maintained at a value effective to prevent depletion of the liquid inventory of the reservoir. 4 figs.
Storage capacity in hot dry rock reservoirs
Brown, Donald W.
1997-01-01
A method of extracting thermal energy, in a cyclic manner, from geologic strata which may be termed hot dry rock. A reservoir comprised of hot fractured rock is established and water or other liquid is passed through the reservoir. The water is heated by the hot rock, recovered from the reservoir, cooled by extraction of heat by means of heat exchange apparatus on the surface, and then re-injected into the reservoir to be heated again. Water is added to the reservoir by means of an injection well and recovered from the reservoir by means of a production well. Water is continuously provided to the reservoir and continuously withdrawn from the reservoir at two different flow rates, a base rate and a peak rate. Increasing water flow from the base rate to the peak rate is accomplished by rapidly decreasing backpressure at the outlet of the production well in order to meet periodic needs for amounts of thermal energy greater than a baseload amount, such as to generate additional electric power to meet peak demands. The rate of flow of water provided to the hot dry rock reservoir is maintained at a value effective to prevent depletion of the liquid
Picoelectrospray Ionization Mass Spectrometry Using Narrow-bore Chemically Etched Emitters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marginean, Ioan; Tang, Keqi; Smith, Richard D.
2014-01-01
Electrospray ionization mass spectrometry (ESI-MS) at flow rates below ~10 nL/min has been only sporadically explored due to difficulty in reproducibly fabricating emitters that can operate at lower flow rates. Here we demonstrate narrow orifice chemically etched emitters for stable electrospray at flow rates as low as 400 pL/min. Depending on the analyte concentration, we observe two types of MS signal response as a function of flow rate. At low concentrations, an optimum flow rate is observed slightly above 1 nL/min, while the signal decreases monotonically with decreasing flow rates at higher concentrations. In spite of lower MS signal, themore » ion utilization efficiency increases exponentially with decreasing flow rate in all cases. No unimolecular response was observed within this flow rate range during the analysis of an equimolar mixture of peptides, indicating that ionization efficiency is an analyte-dependent characteristic in given experimental conditions. While little to no gain in signal-to-noise was achieved at ultralow flow rates for concentration-limited analyses, experiments consuming the same amount of analyte suggest that mass-limited analyses will benefit strongly from the use of low flow rates and avoiding unnecessary sample dilution. By operating under optimal conditions, consumption of just 500 zmol of sample yielded signal-to-noise ratios ~10 for some peptides. These findings have important implications for the analysis of trace biological samples.« less
HYPERHYDRATION AND PAROTID FLOW IN MAN.
Parotid fluid was collected without exogenous stimulation from five groups of 25 subjects each. Each group received a different amount of water...under conditions of forced ingestion. The increase in parotid flow rate brought about by water ingestion was highly significant. Doses of 1,000 ml. or
Dunster, Kimble R; Davies, Mark W; Fraser, John F
2006-01-01
Background The loss of perfluorocarbon (PFC) vapour in the expired gases during partial liquid ventilation should be minimized both to prevent perfluorocarbon vapour entering the atmosphere and to re-use the recovered PFC liquid. Using a substantially modified design of our previously described condenser, we aimed to determine how much perfluorocarbon liquid could be recovered from gases containing PFC and water vapour, at concentrations found during partial liquid ventilation, and to determine if the amount recovered differed with background flow rate (at flow rates suitable for use in neonates). Methods The expiratory line of a standard ventilator circuit set-up was mimicked, with the addition of two condensers. Perfluorocarbon (30 mL of FC-77) and water vapour, at concentrations found during partial liquid ventilation, were passed through the circuit at a number of flow rates and the percentage recovery of the liquids measured. Results From 14.2 mL (47%) to 27.3 mL (91%) of the infused 30 mL of FC-77 was recovered at the flow rates studied. Significantly higher FC-77 recovery was obtained at lower flow rates (ANOVA with Bonferroni's multiple comparison test, p < 0.0001). As a percentage of the theoretical maximum recovery, 64 to 95% of the FC-77 was recovered. Statistically significantly less FC-77 was recovered at 5 Lmin-1 (ANOVA with Bonferroni's multiple comparison test, p < 0.0001). Amounts of perfluorocarbon vapour recovered were 47%, 50%, 81% and 91% at flow rates of 10, 5, 2 and 1 Lmin-1, respectively. Conclusion Using two condensers in series 47% to 91% of perfluorocarbon liquid can be recovered, from gases containing perfluorocarbon and water vapour, at concentrations found during partial liquid ventilation. PMID:16457722
Milk flow rates from bottle nipples used after hospital discharge
Pados, Britt Frisk; Park, Jinhee; Thoyre, Suzanne M.; Estrem, Hayley; Nix, W. Brant
2016-01-01
Purpose To test the milk flow rates and variability in flow rates of bottle nipples used after hospital discharge. Study Design and Methods Twenty-six nipple types that represented 15 common brands as well as variety in price per nipple and store location sold (e.g., Babies R’ Us, Walmart, Dollar Store) were chosen for testing. Ten of each nipple type (n=260 total) were tested by measuring the amount of infant formula expressed in one minute using a breast pump. Mean milk flow rate (mL/min) and coefficient of variation (CV) were calculated. Flow rates of nipples within brand were compared statistically. Results Milk flow rates varied from 1.68 mL/min for the Avent Natural Newborn Flow to 85.34 mL/min for the Dr. Brown’s Standard Y-cut. Variability between nipple types also varied widely, from .03 for the Dr. Brown’s Standard Level 3 to .37 for MAM Nipple 1 Slow Flow. Clinical Implications The extreme range of milk flow rates found may be significant for medically fragile infants being discharged home who are continuing to develop oral feeding skills. The name of the nipple does not provide clear information about the flow rate to guide parents in decision-making. Variability in flow rates within nipples of the same type may complicate oral feeding for the medically fragile infant who may not be able to adapt easily to change in flow rates. Both flow rate and variability should be considered when guiding parents to a nipple choice. PMID:27008466
System using electric furnace exhaust gas to preheat scrap for steelmaking
DOE Office of Scientific and Technical Information (OSTI.GOV)
Takai, K.; Iwasaki, K.
1987-09-08
A method is described for clean preheating of scrap contaminated with oil and organic matter, for steelmaking, using heat from exhaust gas flow from an electric furnace. It consists of: burning any combustibles present in the exhaust gas flow and simultanously separating out dust particles from the exhaust gas flow; heating a predetermined amount of the scrap by heat exchange with a predetermined portion of the exhaust gas flow; removing and collecting dust from the exhaust gas flow after preheating of scrap thereby; sensing the temperature of the exhaust flow; scrubbing the exhaust gas flow with an aqueous solution ofmore » a deodorant solvent flowing at a rate regulated to be in a predetermined relationship related to the exhaust gas temperature sensed prior to scrubbing, thereby generating saturated vapor and reducing the temperature of the exhaust gas flow by a predetermined amount; and electrostatically precipitating out oil mist attached to saturated water vapor and liquid droplets in the exhaust gas flow.« less
Ogino, Takamichi; Ueda, Takayuki; Ogami, Koichiro; Koike, Takashi; Sakurai, Kaoru
2017-01-01
We examined how chewing rate and the extent of reactive hyperemia affect the blood flow in denture-supporting mucosa during chewing. The left palatal mucosa was loaded under conditions of simulated chewing or simulated clenching for 30s, and the blood flow during loading was recorded. We compared the relative blood flow during loading under conditions that recreated different chewing rates by combining duration of chewing cycle (DCC) and occlusal time (OT): fast chewing group, typical chewing group, slow chewing group and clenching group. The relationship between relative blood flow during simulated chewing and the extent of reactive hyperemia was also analyzed. When comparing the different chewing rate, the relative blood flow was highest in fast chewing rate, followed by typical chewing rate and slow chewing rate. Accordingly, we suggest that fast chewing increases the blood flow more than typical chewing or slow chewing. There was a significant correlation between the amount of blood flow during simulated chewing and the extent of reactive hyperemia. Within the limitations of this study, we concluded that slow chewing induced less blood flow than typical or fast chewing in denture-supporting mucosa and that people with less reactive hyperemia had less blood flow in denture-supporting mucosa during chewing. Copyright © 2016 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.
Open-channel integrating-type flow meter
Koopman, K.C.
1971-01-01
A relatively inexpensive meter for measuring cumulative flow in open channels with a rated control,. called a "totalizer", was developed. It translates the nonlinear function of gage height to flow by use of a cam and a float. A variable resistance element in an electronic circuit is controlled by the float so that the electron flow in the circuit corresponds to the flow of water. The flow of electricity causes electroplating of an electrode with silver. The amount of silver deposited is proportionate to the flow of water. The total flow of water is determined by removing the silver from the electrode at a fixed rate with ·an electronic device and recording the time for removal with a counter. The circuit is designed so that the ,resultant reading on the counter is in acre-feet of water.
Unsteady Analysis of Turbine Main Flow Coupled with Secondary Air Flow
NASA Technical Reports Server (NTRS)
Hah, Chunill
2006-01-01
Two numerical approaches are used to model the interaction between the turbine main gas flow and the wheelspace cavity seal flow. The 3-D, unsteady Reynolds-averaged Navier-Stokes equations are solved with a CFD code based on a structured grid to study the interaction between the turbine main gas flow and the wheelspace cavity seal flow. A CFD code based on an unstructured grid is used to solve detailed flow feature in the cavity seal which has a complex geometry. The numerical results confirm various observations from earlier experimental studies under similar flow conditions. When the flow rate through the rim cavity seal is increased, the ingestion of the main turbine flow into the rim seal area decreases drastically. However, a small amount of main gas flow is ingested to the rim seal area even with very high level of seal flow rate. This is due to the complex nature of 3-D, unsteady flow interaction near the hub of the turbine stage.
NASA Astrophysics Data System (ADS)
Cho, S.-J.; Jung, C.-K.; Bae, I.-S.; Song, Y.-H.; Boo, J.-H.
2011-06-01
We have deposited TiOxNy thin films on Si(100) substrates at 500 °C using RF PECVD system. Titanium iso-propoxide was used as precursor with different nitrogen flow rate to control oxygen and nitrogen contents in the films. Changes of chemical states of constituent elements in the deposited films were examined by XPS analysis. The data showed that with increasing nitrogen flow rate, the total amounts of nitrogen and titanium were increased while that of oxygen was decreased, resulting in a binding energy shift toward high energy side. The characteristics of film growth orientation and structure as well as morphology change behavior were also analyzed by XRD, TED, FT-IR, TEM, and SEM. Deposition at higher nitrogen flow rate results in finer clusters with a nanograin size and more effective photocatalytic TiOxNy thin films with hydrophilic surface.
Assessment of Component-level Emission Measurements ...
Oil and natural gas (ONG) production facilities have the potential to emit a substantial amount of greenhouse gasses, hydrocarbons and hazardous air pollutants into the atmosphere. These emissions come from a wide variety of sources including engine exhaust, combustor gases, atmospheric venting from uncontrolled tanks and leaks. Engine exhaust, combustor gases and atmospheric tank venting are included in the initial estimation of a production facilities cumulative emissions. However, there is a large amount of uncertainty associated with magnitude and composition of leaks at these facilities. In order to understand the environmental impacts of these emissions we must first be able characterize the emission flow rate and chemical composition of these leaks/venting. A number of recent publications regarding emission flow rate measurements of components at ONG production facilities have brought into question the validity of such measurements and the sampling methodology. An accurate methodology for quantifying hydrocarbon leaks/venting is needed to support both emission inventories and environmental compliance. This interim report will summarize recent results from a small leak survey completed at ONG production facilities in Utah to characterize their flow rate and chemical composition using a suite of instruments using a high volume sampler (Bacharach Hi Flow Sampler; Bacharach, Inc.), as well as infrared (IR) cameras, a photoionization detector (PID), a fl
Experimental Parameters for Wax Modeling of the Deccan Traps Flood Basalt Province
NASA Astrophysics Data System (ADS)
Rader, E. L.; Vanderkluysen, L.; Clarke, A. B.
2015-12-01
The Deccan Traps consist of ~1,000,000 km3 of predominantly tholeiitic basaltic lava flows, which cover the western Indian subcontinent. Their eruption occurred over a ~1-3 million year period overlapping with the Cretaceous-Paleogene (K-Pg) boundary and, hence, has been implicated in one of the most significant extinction events in the history of the planet. The extent of environmental impacts caused by flood basalt eruptions is thought to be related, in part, to the amount, species, and timescales of volcanic gases released. Therefore, constraining the effusion rate of Deccan Traps lava flows is fundamental to understanding the K-Pg extinction event. Previous field and experimental work with polyethylene glycol (PEG) wax has shown that effusion rate is a primary factor controlling flow morphology. While sinuous flows and lava domes have been successfully recreated with PEG wax, the two most common morphologies seen in the Deccan Traps (compound and inflated sheet lobes) have not. We used heated PEG-400 wax injected into a tank of chilled water with a peristaltic pump to form experimental eruptions with high flow rate and low viscosity to replicate inflated flow lobes, and low flow rate with higher viscosity for compound flows. Unlike previous experiments, flow rate was varied during a single experiment to examine the effect on flow morphology. The Psi value is used as a scaling parameter to estimate effusion rates for compound and 'simple' inflated flows in the Deccan Traps. When combined with field work for volume estimates of the two flow types, these experiments will provide the best constraint on eruption rates to date.
Granato, Gregory E.; Barlow, Paul M.
2005-01-01
Transient numerical ground-water-flow simulation and optimization techniques were used to evaluate potential effects of instream-flow criteria and water-supply demands on ground-water development options and resultant streamflow depletions in the Big River Area, Rhode Island. The 35.7 square-mile (mi2) study area includes three river basins, the Big River Basin (30.9 mi2), the Carr River Basin (which drains to the Big River Basin and is 7.33 mi2 in area), the Mishnock River Basin (3.32 mi2), and a small area that drains directly to the Flat River Reservoir. The overall objective of the simulations was to determine the amount of ground water that could be withdrawn from the three basins when constrained by streamflow requirements at four locations in the study area and by maximum rates of withdrawal at 13 existing and hypothetical well sites. The instream-flow requirement for the outlet of each basin and the outfall of Lake Mishnock were the primary variables that limited the amount of ground water that could be withdrawn. A requirement to meet seasonal ground-water-demand patterns also limits the amount of ground water that could be withdrawn by up to about 50 percent of the total withdrawals without the demand-pattern constraint. Minimum water-supply demands from a public water supplier in the Mishnock River Basin, however, did not have a substantial effect on withdrawals in the Big River Basin. Hypothetical dry-period instream-flow requirements and the effects of artificial recharge also affected the amount of ground water that could be withdrawn. Results of simulations indicate that annual average ground-water withdrawal rates that range up to 16 million gallons per day (Mgal/d) can be withdrawn from the study area under simulated average hydrologic conditions depending on instream-flow criteria and water-supply demand patterns. Annual average withdrawals of 10 to 12 Mgal/d are possible for proposed demands of 3.4 Mgal/d in the Mishnock Basin, and for a constant annual instream-flow criterion of 0.5 cubic foot per second per square mile (ft3/s/mi2) at the four streamflow-constraint locations. An average withdrawal rate of 10 Mgal/d can meet estimates of future (2020) water-supply needs of surrounding communities in Rhode Island. This withdrawal rate represents about 13 percent of the average 2002 daily withdrawal from the Scituate Reservoir (76 Mgal/d), the State?s largest water supply. Average annual withdrawal rates of 6 to 7 Mgal/d are possible for more stringent instream-flow criteria that might be used during dry-period hydrologic conditions. Two example scenarios of dry-period instream-flow constraints were evaluated: first, a minimum instream flow of 0.1 cubic foot per second at any of the four constraint locations; and second, a minimum instream flow of 10 percent of the minimum monthly streamflow estimate for each streamflow-constraint location during the period 1961?2000. The State of Rhode Island is currently (2004) considering methods for establishing instream-flow criteria for streams within the State. Twelve alternative annual, seasonal, or monthly instream-flow criteria that have been or are being considered for application in southeastern New England were used as hypothetical constraints on maximum ground-water-withdrawal rates in management-model calculations. Maximum ground-water-withdrawal rates ranged from 5 to 16 Mgal/d under five alternative annual instream-flow criteria. Maximum ground-water-withdrawal rates ranged from 0 to 13.6 Mgal/d under seven alternative seasonal or monthly instream-flow criteria. The effect of ground-water withdrawals on seasonal variations in monthly average streamflows under each criterion also were compared. Evaluation of management-model results indicates that a single annual instream-flowcriterion may be sufficient to preserve seasonal variations in monthly average streamflows and meet water-supply demands in the Big River Area, because withdrawals from wells in the Big
Liquid Jet Cavitation via Molecular Dynamics
NASA Astrophysics Data System (ADS)
Ashurst, W. T.
1997-11-01
A two-dimensional molecular dynamics simulation of a liquid jet is used to investigate cavitation in a diesel-like fuel injector. A channel with a length four times its width has been examined at various system sizes (widths of 20 to 160 σ, where σ is the zero energy location in the Lennard-Jones potential). The wall boundary condition is Maxwell's diffuse reflection, similar to the work by Sun & Ebner (Phys. Rev A 46, 4813, 1992). Currently, the jet exhausts into a vacuum, but a second, low density gas will be incorporated to represent the compressed air in a diesel chamber. Four different flow rates are examined. With ρ U equal to √mɛ/σ^2 (the largest flow rate) the static pressure decreases by a factor of twenty between the channel entrance and exit. The largest flow rate has a parabolic velocity profile with almost constant density across the channel. The smallest flow rate has the same velocity profile but the density exhibits a large variation, with the minimum value in the channel center. Thus, the product ρ U is nearly constant across the channel at this flow rate. The discharge coefficient CD has a small variation with flow rate, but the velocity coefficient CV varies with the amount of two-phase fluid within the channel. The ratio of CV to CD varies from 1.3 (largest flow rate) to 2.0 (the smallest flow rate, which is one-eighth of the largest).
A mathematical model for the iron/chromium redox battery
NASA Technical Reports Server (NTRS)
Fedkiw, P. S.; Watts, R. W.
1984-01-01
A mathematical model has been developed to describe the isothermal operation of a single anode-separator-cathode unit cell in a redox-flow battery and has been applied to the NASA iron/chromium system. The model, based on porous electrode theory, incorporates redox kinetics, mass transfer, and ohmic effects as well as the parasitic hydrogen reaction which occurs in the chromium electrode. A numerical parameter study was carried out to predict cell performance to aid in the rational design, scale-up, and operation of the flow battery. The calculations demonstrate: (1) an optimum electrode thickness and electrolyte flow rate exist; (2) the amount of hydrogen evolved and, hence, cycle faradaic efficiency, can be affected by cell geometry, flow rate, and charging procedure; (3) countercurrent flow results in enhanced cell performance over cocurrent flow; and (4) elevated temperature operation enhances cell performance.
Evaluation of IOM personal sampler at different flow rates.
Zhou, Yue; Cheng, Yung-Sung
2010-02-01
The Institute of Occupational Medicine (IOM) personal sampler is usually operated at a flow rate of 2.0 L/min, the rate at which it was designed and calibrated, for sampling the inhalable mass fraction of airborne particles in occupational environments. In an environment of low aerosol concentrations only small amounts of material are collected, and that may not be sufficient for analysis. Recently, a new sampling pump with a flow rate up to 15 L/min became available for personal samplers, with the potential of operating at higher flow rates. The flow rate of a Leland Legacy sampling pump, which operates at high flow rates, was evaluated and calibrated, and its maximum flow was found to be 10.6 L/min. IOM samplers were placed on a mannequin, and sampling was conducted in a large aerosol wind tunnel at wind speeds of 0.56 and 2.22 m/s. Monodisperse aerosols of oleic acid tagged with sodium fluorescein in the size range of 2 to 100 microm were used in the test. The IOM samplers were operated at flow rates of 2.0 and 10.6 L/min. Results showed that the IOM samplers mounted in the front of the mannequin had a higher sampling efficiency than those mounted at the side and back, regardless of the wind speed and flow rate. For the wind speed of 0.56 m/s, the direction-averaged (the average value of all orientations facing the wind direction) sampling efficiency of the samplers operated at 2.0 L/min was slightly higher than that of 10.6 L/min. For the wind speed of 2.22 m/s, the sampling efficiencies at both flow rates were similar for particles < 60 microm. The results also show that the IOM's sampling efficiency at these two different flow rates follows the inhalable mass curve for particles in the size range of 2 to 20 microm. The test results indicate that the IOM sampler can be used at higher flow rates.
Powell, Karin; Ethun, Kelly; Taylor, Douglas K
2016-09-21
Euthanasia protocols are designed to mitigate the stress experienced by animals, and an environment that induces minimal stress helps achieve that goal. A protocol that is efficient and practical in a typical animal research facility is also important. Light intensity, isoflurane, and CO2 flow rate were studied for their impact on the stress response of mice during CO2 euthanasia. Behavior was observed and scored during euthanasia and serum corticosterone was measured immediately after death. Unsurprisingly, animals euthanized with a high-flow rate of CO2 became unconscious in the least amount of time, while animals euthanized with a low-flow rate required the most time to reach unconsciousness. There was a significant increase in anxious behaviors in animals in the isoflurane group (F1,12 = 6.67, P = 0.024), the high-flow rate CO2 group (F1,12 = 10.24, P = 0.007), and bright chamber group (F1,12 = 7.27, P = 0.019). Serum corticosterone was highest in the isoflurane group (124.72 ± 83.98 ng/ml), however there was no significant difference in corticosterone levels observed for the other study variables of light and flow-rate. A darkened chamber and low CO2 flow rates help to decrease stress experienced during CO2 euthanasia, while the use of isoflurane was observed to increase the stress response during euthanasia.
Water injected fuel cell system compressor
Siepierski, James S.; Moore, Barbara S.; Hoch, Martin Monroe
2001-01-01
A fuel cell system including a dry compressor for pressurizing air supplied to the cathode side of the fuel cell. An injector sprays a controlled amount of water on to the compressor's rotor(s) to improve the energy efficiency of the compressor. The amount of water sprayed out the rotor(s) is controlled relative to the mass flow rate of air inputted to the compressor.
NASA Astrophysics Data System (ADS)
Yuliusman; Afdhol, M. K.; Sanal, Alristo
2018-03-01
Carbon monoxide and methane gas are widely present in oil refineries. Off-potential gas is used as raw material for the petrochemical industry. In order for this off-gas to be utilized, carbon monoxide and methane must be removed from off-gas. This study aims to adsorb carbon monoxide and methane using activated carbon of palm shells and commercial activated carbon simultaneously. This research was conducted in 2 stages: 1) Preparation and characterization of activated carbon, 2) Carbon monoxide and methane adsorption test. The activation experiments using carbon dioxide at a flow rate of 150 ml/min yielded a surface area of 978.29 m2/g, Nitrogen at flow rate 150 ml/min yielded surface area 1241.48 m2/g, and carbon dioxide and nitrogen at a flow rate 200 ml/min yielded a surface area 300.37 m2/g. Adsorption of carbon monoxide and methane on activated carbon of palm shell systems yielded results in the amount of 0.5485 mg/g and 0.0649 mg/g and using commercial activated carbon yielded results in the amount of 0.5480 mg/g and 0.0650 mg/g
City traffic flow breakdown prediction based on fuzzy rough set
NASA Astrophysics Data System (ADS)
Yang, Xu; Da-wei, Hu; Bing, Su; Duo-jia, Zhang
2017-05-01
In city traffic management, traffic breakdown is a very important issue, which is defined as a speed drop of a certain amount within a dense traffic situation. In order to predict city traffic flow breakdown accurately, in this paper, we propose a novel city traffic flow breakdown prediction algorithm based on fuzzy rough set. Firstly, we illustrate the city traffic flow breakdown problem, in which three definitions are given, that is, 1) Pre-breakdown flow rate, 2) Rate, density, and speed of the traffic flow breakdown, and 3) Duration of the traffic flow breakdown. Moreover, we define a hazard function to represent the probability of the breakdown ending at a given time point. Secondly, as there are many redundant and irrelevant attributes in city flow breakdown prediction, we propose an attribute reduction algorithm using the fuzzy rough set. Thirdly, we discuss how to predict the city traffic flow breakdown based on attribute reduction and SVM classifier. Finally, experiments are conducted by collecting data from I-405 Freeway, which is located at Irvine, California. Experimental results demonstrate that the proposed algorithm is able to achieve lower average error rate of city traffic flow breakdown prediction.
Maiguy-Foinard, Aurélie; Genay, Stéphanie; Lannoy, Damien; Barthélémy, Christine; Lebuffe, Gilles; Debaene, Bertrand; Odou, Pascal; Décaudin, Bertrand
2017-02-01
The aims are to identify critical parameters influencing the drug mass flow rate of infusion delivery to patients during multidrug infusion and to discuss their clinical relevance. A review of literature was conducted in January 2016 using Medline, Google Scholar, ScienceDirect, Web of Science and Scopus online databases. References relating to the accuracy of fluid delivery via gravity-flow intravenous (IV) infusion systems and positive displacement pumps, components of IV administration sets, causes of flow rate variability, potential complications due to flow rate variability, IV therapies especially at low flow rates and drug compatibilities were considered relevant. Several parameters impact the delivery of drugs and fluids by IV infusion. Among them are the components of infusion systems that particularly influence the flow rate of medications and fluids being delivered. By their conception, they may generate significant start-up delays and flow rate variability. Performing multidrug infusion requires taking into account two main points: the common dead volume of drugs delivered simultaneously with potential consequences on the accuracy and amount of drug delivery and the prevention of drug incompatibilities and their clinical effects. To prevent the potentially serious effects of flow rate variability on patients, clinicians should receive instruction on the fluid dynamics of an IV administration set and so be able to take steps to minimise flow rate changes during IV therapy. Copyright © 2016 Société française d’anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.
NASA Astrophysics Data System (ADS)
Zhang, Y.; Zhang, G.; Lu, P.; Hu, B.; Zhu, C.
2017-12-01
The extent of CO2 mineralization after CO2 injection into deep saline aquifers is a result of the complex coupling of multiphase fluid flow, mass transport, and brine-mineral reactions. The effects of dissolution rate laws and groundwater flow on the long-term fate of CO2 have been seriously overlooked. To investigate these effects, we conducted multiphase (CO2 and brine) coupled reactive transport modeling of CO2 storage in two sandy formations (Utsira Sand, Norway1,2 and Mt. Simon formation, USA 3) using ToughReact and simulated a series of scenarios. The results indicated that: (1) Different dissolution rate laws for feldspars can significantly affect the amount of CO2 mineralization. Increased feldspar dissolution will promote CO2 mineral trapping through the coupling between feldspar dissolution and carbonate mineral precipitation at raised pH. The predicted amount of CO2 mineral trapping when using the principle of detailed balancing-based rate law for feldspar dissolution is about twice as much as that when using sigmoidal rate laws in the literature. (2) Mineral trapping is twice as much when regional groundwater flow is taken into consideration in long-term simulations (e.g., 10,000 years) whereas most modeling studies neglected the regional groundwater flow back and effectively simulated a batch reactor process. Under the influence of regional groundwater flow, the fresh brine from upstream continuously dissolves CO2 at the tail of CO2 plume, generating a large acidified area where large amount of CO2 mineralization takes place. The upstream replenishment of groundwater results in ˜22% mineral trapping at year 10,000, compared to ˜4% when this effect is ignored. Refs: 1Zhang, G., Lu, P., Wei, X., Zhu, C. (2016). Impacts of Mineral Reaction Kinetics and Regional Groundwater Flow on Long-Term CO2 Fate at Sleipner. Energy & Fuels, 30(5), 4159-4180. 2Zhu, C., Zhang, G., Lu, P., Meng, L., Ji, X. (2015). Benchmark modeling of the Sleipner CO2 plume: Calibration to seismic data for the uppermost layer and model sensitivity analysis. International Journal of Greenhouse Gas Control, 43, 233-246. 3Zhang, G., Lu, P., Zhang, Y., Wei, X., Zhu, C. (2015). Effects of rate law formulation on predicting CO2 sequestration in sandstone formations. International Journal of Energy Research, 39(14), 1890-1908.
Variability in venom volume, flow rate and duration in defensive stings of five scorpion species.
van der Meijden, Arie; Coelho, Pedro; Rasko, Mykola
2015-06-15
Scorpions have been shown to control their venom usage in defensive encounters, depending on the perceived threat. Potentially, the venom amount that is injected could be controlled by reducing the flow speed, the flow duration, or both. We here investigated these variables by allowing scorpions to sting into an oil-filled chamber, and recording the accreting venom droplets with high-speed video. The size of the spherical droplets on the video can then be used to calculate their volume. We recorded defensive stings of 20 specimens representing 5 species. Significant differences in the flow rate and total expelled volume were found between species. These differences are likely due to differences in overall size between the species. Large variation in both venom flow speed and duration are described between stinging events of single individuals. Both venom flow rate and flow duration correlate highly with the total expelled volume, indicating that scorpions may control both variables in order to achieve a desired end volume of venom during a sting. Copyright © 2015 Elsevier Ltd. All rights reserved.
Combustion in a multiburner furnace with selective flow of oxygen
Bool, III, Lawrence E.; Kobayashi, Hisashi
2004-03-02
Improved operational characteristics such as improved fuel efficiency, reduction of NOx formation, reduction of the amount of unburned carbon in the ash, and lessened tendency to corrosion at the tube wall, in a multi-burner furnace are obtained by reducing the flow rate of combustion air to the burners and selectively individually feeding oxidant to only some of the burners.
Cooling flows and X-ray emission in early-type galaxies
NASA Technical Reports Server (NTRS)
Sarazin, Craig L.
1990-01-01
The X-ray properties of normal early-type galaxies and the limited theoretical understanding of the physics of the hot interstellar medium in these galaxies are reviewed. A number of simple arguments about the physical state of the gas are given. Steady-state cooling flow models for these galaxies are presented, and their time-dependent evolution is discussed. The X-ray emission found in early-type galaxies indicates that they contain significant amounts of hot interstellar gas, and that they are not the gas-poor systems they were previously thought to be. In the brighter X-ray galaxies, the amounts of hot gas observed are consistent with those expected given the present rates of stellar mass loss. The required rates of heating of the gas are consistent with those expected from the motions of gas-losing stars and supernovae. The X-ray observations are generally more consistent with a lower rate of Type I supernovae than was previously thought.
NASA Astrophysics Data System (ADS)
Herring, Anna L.; Middleton, Jill; Walsh, Rick; Kingston, Andrew; Sheppard, Adrian
2017-09-01
We investigate capillary pressure-saturation (PC-S) relationships for drainage-imbibition experiments conducted with air (nonwetting phase) and brine (wetting phase) in Bentheimer sandstone cores. Three different flow rate conditions, ranging over three orders of magnitude, are investigated. X-ray micro-computed tomographic imaging is used to characterize the distribution and amount of fluids and their interfacial characteristics. Capillary pressure is measured via (1) bulk-phase pressure transducer measurements, and (2) image-based curvature measurements, calculated using a novel 3D curvature algorithm. We distinguish between connected (percolating) and disconnected air clusters: curvatures measured on the connected phase interfaces are used to validate the curvature algorithm and provide an indication of the equilibrium condition of the data; curvature and volume distributions of disconnected clusters provide insight to the snap-off processes occurring during drainage and imbibition under different flow rate conditions.
NASA Astrophysics Data System (ADS)
Fang, Min; Xu, Ke-Jun; Zhu, Wen-Jiao; Shen, Zi-Wen
2016-01-01
Most of the ultrasonic gas flow-meters measure the gas flow rate by calculating the ultrasonic transmission time difference between the downstream and upstream. Ultrasonic energy attenuation occurs in the processes of the ultrasonic generation, conversion, transmission, and reception. Additionally, at the same time, the gas flow will also affect the ultrasonic propagation during the measurement, which results in the ultrasonic energy attenuation and the offset of ultrasonic propagation path. Thus, the ultrasonic energy received by the transducer is weaker. When the gas flow rate increases, this effect becomes more apparent. It leads to the measurement accuracy reduced, and the measurement range narrowed. An energy transfer model, where the ultrasonic gas flow-meter under without/with the gas flow, is established by adopting the statistical analysis and curve fitting based on a large amount of experimental data. The static sub model without the gas flow expresses the energy conversion efficiency of ultrasonic gas transducers, and the dynamic sub model with the gas flow reflects the energy attenuation pattern following the flow rate variations. The mathematical model can be used to determine the minimum energy of the excitation signal for meeting the requirement of specific measurement range, and predict the maximum measurable flow rate in the case of fixed energy of excitation signal. Based on the above studies, a method to enhance the excitation signal energy is proposed under the output power of the transmitting circuit being a finite value so as to extend the measurement rage of ultrasonic gas flow-meter.
Accuracy and consistency of drop delivery in infusion pumps.
Yau, K I; Miyasaka, K
1990-04-01
Advances in intensive care medicine has made us more depend on infusion pumps to deliver accurate amounts of fluids to sick newborns, children and adults. When infusing rapid-acting critical drugs to patients, it is important not only to deliver accurate fluid-volume amounts over a specified time, but also to deliver the fluid at a constant rate with minimal fluctuation. The accuracy of drop delivery in four infusion pumps (IVAC 530, IVAC 560, IMED 922 and IMED 960) at different infusion rates were examined in a laboratory setting by using a photoelectric sensor and a computer. When it was not in its cassette-filling period, the IMED 960 was the most accurate at delivering fluid-drops, with a coefficient of variance (CV) of less than 10% at each flow rate. Yet, like other piston-cylinder cassette pumps, its cassette filling time and stabilizing period after cassette filling were longer at lower flow rates. Both the IVAC 530 and the IMED 922 delivered fluids irregularly with large coefficients of variance (CVs). IVAC 560 had the best results for consistency of drop-delivery over a 4-hour period.
Effects of dose, flow rate, and bile acid on diclofenac disposition in the perfused rat liver.
Uraki, Misato; Kawase, Atsushi; Matsushima, Yuka; Iwaki, Masahiro
2016-06-01
An in situ perfused rat liver system is useful for studying the hepatic disposition of drugs and their metabolites. However, the effects of the perfusion conditions on drug disposition are unclear. We examined the effects of conditions such as flow rate (13 or 26 mL/min) and bile acid on disposition of diclofenac (DF) as a model drug and DF metabolites [diclofenac-1-O-acyl glucuronide (DF-Glu) or 4'-hydroxydiclofenac (DF-4'OH)] in the absence of albumin. DF, DF-Glu, and DF-4'OH concentrations in the perfusate and cumulative amounts of DF-Glu excreted in bile were measured using high-performance liquid chromatography methods. DF in the perfusate was rapidly eliminated as the perfusate flow rate increased. The area under the plasma concentration-time curve from 0 to 60 min (AUC0-60) for DF-Glu and DF-4'OH in a perfusate containing bile acid was lower at a flow rate of 26 and 13 mL/min, respectively. The bile flow rate at 26 mL/min with 24 μM of bile acid in the perfusate was significantly higher (ca. 3.5 times) compared with that at 13 mL/min without bile acid. Cumulative biliary DF-Glu excretion was also dramatically affected by the flow rate and addition of bile acid. This study indicated that the flow rate and bile acid in the perfused rat liver were key factors for bile flow rate and DF, DF-Glu, and DF-4'OH disposition in the absence of albumin.
The Congress Should Control Federal Credit Programs to Promote Economic Stabilization.
1981-10-21
economic stability since 1960. The current rate of direct and guaranteed loan flows will exceed $70 billion annually in fiscal 1981. Recently, the Congress and the Administration have proposed a credit budget to limit the rapid growth of Federal credit. GAO demonstrates in this report that the best point of program control is the amount of the interest rate subsidy. Controlling subsidy levels rather than program activity levels would allocate credit efficiently and would, at the same time, lead to Federal credit flows that would contribute to the economic stabilization
Development of braided rope seals for hypersonic engine applications. Part 2: Flow modeling
NASA Technical Reports Server (NTRS)
Mutharasan, Rajakkannu; Steinetz, Bruce M.; Tao, Xiaoming; Ko, Frank
1991-01-01
Two models based on the Kozeny-Carmen equation were developed to analyze the fluid flow through a new class of braided rope seals under development for advanced hypersonic engines. A hybrid seal geometry consisting of a braided sleeve and a substantial amount of longitudinal fibers with high packing density was selected for development based on its low leakage rates. The models developed allow prediction of the gas leakage rate as a function of fiber diameter, fiber packing density, gas properties, and pressure drop across the seal.
Selective sequential precipitation of dissolved metals in mine drainage from coal mine
NASA Astrophysics Data System (ADS)
Yim, Giljae; Bok, Songmin; Ji, Sangwoo; Oh, Chamteut; Cheong, Youngwook; Han, Youngsoo; Ahn, Joosung
2017-04-01
In abandoned mines in Korea, a large amount of mine drainage continues to flow out and spread pollution. In purification of the mine drainage a massive amount of sludge is generated as waste. Since this metal sludge contains high Fe, Al and Mn oxides, developing the treatment method to recover homogeneous individual metal with high purity may beneficial to recycle waste metals as useful resources and reduce the amount of sludge production. In this regard, we established a dissolved metals selective precipitation process to treat Waryong Industry's mine drainage. The process that selectively precipitates metals dissolved in mine drainage is a continuous Fe-buffer-Al process, and each process consists of the neutralization tank, the coagulation tank, and the settling tank. Based on this process, this study verified the operational applicability of the Fe and Al selective precipitation. Our previous study revealed that high-purity Fe and Al precipitates could be recovered at a flow rate of 1.5 ton/day, while the lower purity was achieved when the rate was increased to about 3 ton/day due to the difficulty in reagent dosage control. In the current study was conducted to increase the capacity of the system to recover Fe and Al as high-purity precipitates at a flow rate of 10 ton/day with the ensured continuous operations by introducing an automatic reagent injection system. The previous study had a difficulty in controlling the pH and operating system continuously due to the manually controlled reagent injection system. To upgrade this and ensure the optimal pH in a stable way, a continuous reagent injection system was installed. The result of operation of the 10 ton/day system confirmed that the scaled-up process could maintain the stable recovery rates and purities of precipitates on site.
Flow monitoring and control system for injection wells
Corey, John C.
1993-01-01
A system for monitoring and controlling the injection rate of fluid by an injection well of an in-situ remediation system for treating a contaminated groundwater plume. The well is fitted with a gated insert, substantially coaxial with the injection well. A plurality of openings, some or all of which are equipped with fluid flow sensors and gates, are spaced along the insert. The gates and sensors are connected to a surface controller. The insert may extend throughout part of, or substantially the entire length of the injection well. Alternatively, the insert may comprise one or more movable modules which can be positioned wherever desired along the well. The gates are opened part-way at the start of treatment. The sensors monitor and display the flow rate of fluid passing through each opening on a controller. As treatment continues, the gates are opened to increase flow in regions of lesser flow, and closed to decrease flow in regions of greater flow, thereby approximately equalizing the amount of fluid reaching each part of the plume.
Flow monitoring and control system for injection wells
Corey, J.C.
1993-02-16
A system for monitoring and controlling the injection rate of fluid by an injection well of an in-situ remediation system for treating a contaminated groundwater plume. The well is fitted with a gated insert, substantially coaxial with the injection well. A plurality of openings, some or all of which are equipped with fluid flow sensors and gates, are spaced along the insert. The gates and sensors are connected to a surface controller. The insert may extend throughout part of, or substantially the entire length of the injection well. Alternatively, the insert may comprise one or more movable modules which can be positioned wherever desired along the well. The gates are opened part-way at the start of treatment. The sensors monitor and display the flow rate of fluid passing through each opening on a controller. As treatment continues, the gates are opened to increase flow in regions of lesser flow, and closed to decrease flow in regions of greater flow, thereby approximately equalizing the amount of fluid reaching each part of the plume.
Li, Haiyan; Li, Mingyi; Zhang, Xiaoran
2013-01-01
The effects of pH, temperature, dissolved oxygen (DO), and flow rate on the phosphorus (P) release processes at the sediment and water interface in rainwater pipes were investigated. The sampling was conducted in a residential storm sewer of North Li Shi Road in Xi Cheng District of Beijing on August 3, 2011. The release rate of P increased with the increase of pH from 8 to 10. High temperature is favorable for the release of P. The concentration of total phosphorus (TP) in the overlying water increased as the concentration of DO decreased. With the increase of flow rate from 0.7 m s−1 to 1.1 m s−1, the concentration of TP in the overlying water increased and then tends to be stable. Among all the factors examined in the present study, the flow rate is the primary influence factor on P release. The cumulative amount of P release increased with the process of pipeline runoff in the rainfall events with high intensities and shorter durations. Feasible measures such as best management practices and low-impact development can be conducted to control the P release on urban sediments by slowing down the flow rate. PMID:24349823
Developing VTM-51 into an ASTM test method.
DOT National Transportation Integrated Search
1993-01-01
In 1980, the Virginia Transportation Research Council developed a procedure to test silt fence installations (VTM-51). The test determines the filtering efficiency (amount of soil removed) and the flow rate of a geotextile. A known concentration and ...
QIVIVE Approaches to Evaluate Interindividual Toxicokinetic Variability
Toxicokinetic (TK) variability across life-stages and populations can significantly impact the amount of chemical available systemically to elicit an effect despite similar external exposures. This variability is driven by physiologic (e.g., liver weights, blood flow rates, etc.)...
Habitat availability vs. flow rate for the Pecos River, Part 1 : Depth and velocity availability.
DOE Office of Scientific and Technical Information (OSTI.GOV)
James, Scott Carlton; Schaub, Edward F.; Jepsen, Richard Alan
2004-02-01
The waters of the Pecos River in New Mexico must be delivered to three primary users: (1) The Pecos River Compact: each year a percentage of water from natural river flow must be delivered to Texas; (2) Agriculture: Carlsbad Irrigation District has a storage and diversion right and Fort Sumner Irrigation District has a direct flow diversion right; and, (3) Endangered Species Act: an as yet unspecified amount of water is to support Pecos Bluntnose Shiner Minnow habitat within and along the Pecos River. Currently, the United States Department of Interior Bureau of Reclamation, the New Mexico Interstate Stream Commission,more » and the United States Department of the Interior Fish and Wildlife Service are studying the Pecos Bluntnose Shiner Minnow habitat preference. Preliminary work by Fish and Wildlife personnel in the critical habitat suggest that water depth and water velocity are key parameters defining minnow habitat preference. However, river flows that provide adequate preferred habitat to support this species have yet to be determined. Because there is a limited amount of water in the Pecos River and its reservoirs, it is critical to allocate water efficiently such that habitat is maintained, while honoring commitments to agriculture and to the Pecos River Compact. This study identifies the relationship between Pecos River flow rates in cubic feet per second (cfs) and water depth and water velocity.« less
Effect of Chamber Backpressure on Swirl Injector Fluid Mechanics
NASA Technical Reports Server (NTRS)
Kenny, R. Jeremy; Hulka, James R.; Moser, Marlow D.; Rhys, Noah O.
2008-01-01
A common propellant combination used for high thrust generation is GH2/LOX. Historical GH2/LOX injection elements have been of the shear-coaxial type. Element type has a large heritage of research work to aid in element design. The swirl-coaxial element, despite its many performance benefits, has a relatively small amount of historical, LRE-oriented work to draw from. Design features of interest are grounded in the fluid mechanics of the liquid swirl process itself, are based on data from low-pressure, low mass flow rate experiments. There is a need to investigate how high ambient pressures and mass flow rates influence internal and external swirl features. The objective of this research is to determine influence of varying liquid mass flow rate and ambient chamber pressure on the intact-length fluid mechanics of a liquid swirl element.
NASA Technical Reports Server (NTRS)
Burley, Richard R.; Harrington, Douglas E.
1987-01-01
An experimental investigation was conducted in the slotted test section of the 0.1-scale model of the proposed Altitude Wind Tunnel to evaluate wall interference effects at tunnel Mach numbers from 0.70 to 0.95 on bodies of revolution with blockage rates of 0.43, 3, 6, and 12 percent. The amount of flow that had to be removed from the plenum chamber (which surrounded the slotted test section) by the plenum evacuation system (PES) to eliminate wall interference effects was determined. The effectiveness of tunnel reentry flaps in removing flow from the plenum chamber was examined. The 0.43-percent blockage model was the only one free of wall interference effects with no PES flow. Surface pressures on the forward part of the other models were greater than interference-free results and were not influenced by PES flow. Interference-free results were achieved on the aft part of the 3- and 6-percent blockage models with the proper amount of PES flow. The required PES flow was substantially reduced by opening the reentry flaps.
Dorr, Paul M; Nemechek, Megan S; Scheidt, Alan B; Baynes, Ronald E; Gebreyes, Wondwossen A; Almond, Glen W
2009-08-01
To evaluate variation of drinking-water flow rates in swine finishing barns and the relationship between drinker flow rate and plasma tetracycline concentrations in pigs housed in different pens. Cross-sectional (phase 1) and cohort (phase 2) studies. 13 swine finishing farms (100 barns with 7,122 drinkers) in phase 1 and 100 finishing-stage pigs on 2 finishing farms (1 barn/farm) in phase 2. In phase 1, farms were evaluated for water-flow variation, taking into account the following variables: position of drinkers within the barn, type of drinker (swing or mounted), pig medication status, existence of designated sick pen, and existence of leakage from the waterline. In phase 2, blood samples were collected from 50 pigs/barn (40 healthy and 10 sick pigs) in 2 farms at 0, 4, 8, 24, 48, and 72 hours after initiation of water-administered tetracycline HCl (estimated dosage, 22 mg/kg [10 mg/lb]). Plasma tetracycline concentrations were measured via ultraperformance liquid chromatography. Mean farm drinker flow rates ranged from 1.44 to 2.77 L/min. Significant differences in flow rates existed according to drinker type and whether tetracycline was included in the water. Mean drinker flow rates and plasma tetracycline concentrations were significantly different between the 2 farms but were not different between healthy and sick pigs. The plasma tetracycline concentrations were typically < 0.3 microg/mL. Many factors affected drinker flow rates and therefore the amount of medication pigs might have received. Medication of pigs with tetracycline through water as performed in this study had questionable therapeutic value.
2008-10-08
of reactant to ferrocene and xylene, a liquid carbon source, results in longer nanostructures in larger amount as shown in Fig. 2(g). These samples...with 6.5 mol% ferrocene and 100 mol% xylene. The flow rate was (e) 0.195 ml/hr, (f) 0.98 ml/hr, and (g) 1.95 ml/hr. (d) and (h) are HR-TEM images of...and ferrocene . The flow rate was (a) 0.195 ml/hr and (b) 1.95 ml/hr........................ 19 Fig. A-5. STEM EDS analysis of the CF specimen after
Hillslope-channel coupling in a steep Hawaiian catchment accelerates erosion rates over 100-fold
NASA Astrophysics Data System (ADS)
Stock, J. D.; Hanshaw, M. N.; Rosener, M.; Schmidt, K. M.; Brooks, B. A.; Tribble, G.; Jacobi, J.
2009-12-01
In tropical watersheds, hillslope changes are producing increasing amounts of fine sediment that can be quickly carried to reefs by channels. Suspended sediment concentrations off the reefs of Molokai, Hawaii, chronically exceed a toxic level of 10 mg/L, threatening reef ecosystems. We hypothesize that historic conversion of watersheds from soil creep to overland flow erosion increased both magnitude and frequency of sediment flooding adjacent reefs. We combined surficial and ecological mapping, hillslope and stream gages, and novel sensors to locate, quantify and model the generation of fine sediments polluting the Molokai reef. Ecological and geomorphic mapping from LiDAR and multi-spectral imagery located a subset of overland flow areas with vegetation cover below a threshold value preventing erosion. Here, feral goat grazing exposed cohesive volcanic soils whose low matrix hydraulic conductivities (1-20 mm/hour) promote Horton overland flow erosion. We instrumented steep, barren hillslopes with soil moisture sensors, overland flow meters, Parshall flumes, ISCO sediment samplers, and a rain gage and conducted repeat Tripod LiDAR and infiltration tests. To characterize soil resistance here and elsewhere to overland flow erosion, we deployed a Cohesive Strength Meter (CSM) to simulate the stresses of flowing water. At the 13.5 km 2 watershed mouth we used a USGS stream gage and ISCO sediment sampler to estimate total load. Over 2 years, storms triggered overland flow during rainfall intensities above 10-15 mm/hr. Overland flow meters indicate such flows can be up to 3 cm deep, with a tendency to deepen downslope. CSM tests indicate that these depths are insufficient to erode soils where vegetation is dense, but far above threshold values of 2-3 mm depth for bare soil erosion. Sediment ratings curves for both hillslope and downstream catchment gages show strong clock-wise hysteresis during the first intense storms in the Fall, becoming linear later in the rainy season. During Fall storms, sediment concentration is often 10X higher at a given stage. During intense Fall storms, we measured erosion rates using erosion pins (1.0 cm/a), suspended sediment flux (1.5 cm/a) and repeat tripod LiDAR (1.7 cm/a). These rates are at least 100-fold greater than the long-term lowering rate of 0.13 mm/a. A sediment budget constructed by extrapolating hillslope lowering rates to the portions of the catchments mapped as overland flow hotspots predicts a total yearly flux of ~ 6500 t, in agreement with the measured total of ~6200 t. A decadal record illustrates that rainfall intensities sufficient to generate overland flow occur for at least 8-10 hours every year, coincident with 1-3 large storm events. We hypothesize that high lowering rates reflect a combination of long-duration overland flow events, and availability of weathered soils that can be entrained by thin flows. It appears that the generation of loose, seasonally weathered silt is a 1st order control on the amount of sediment exported to the reef. If climate change increases storm frequency or duration, or decreases vegetation cover, sediment loading rates to the reef here could increase dramatically.
Design and Performance of the Sorbent-Based Atmosphere Revitalization System for Orion
NASA Technical Reports Server (NTRS)
Ritter, James A.; Reynolds, Steven P.; Ebner, Armin D.; Knox, James C.; LeVan, M. Douglas
2007-01-01
Validation and simulations of a real-time dynamic cabin model were conducted on the sorbent-based atmosphere revitalization system for Orion. The dynamic cabin model, which updates the concentration of H2O and CO2 every second during the simulation, was able to predict the steady state model values for H2O and CO2 for long periods of steady metabolic production for a 4-person crew. It also showed similar trends for the exercise periods, where there were quick changes in production rates. Once validated, the cabin model was used to determine the effects of feed flow rate, cabin volume and column volume. A higher feed flow rate reduced the cabin concentrations only slightly over the base case, a larger cabin volume was able to reduce the cabin concentrations even further, and the lower column volume led to much higher cabin concentrations. Finally, the cabin model was used to determine the effect of the amount of silica gel in the column. As the amount increased, the cabin concentration of H2O decreased, but the cabin concentration of CO2 increased.
Sustained High Basal Motion of the Greenland Ice Sheet Revealed by Borehole Deformation
NASA Technical Reports Server (NTRS)
Ryser, Claudia; Luthi, Martin P.; Andrews, Lauren C.; Hoffman, Matthew, J.; Catania, Ginny A.; Hawley, Robert L.; Neumann, Thomas A.; Kristensen, Steen S.
2014-01-01
Ice deformation and basal motion characterize the dynamical behavior of the Greenland ice sheet (GrIS). We evaluate the contribution of basal motion from ice deformation measurements in boreholes drilled to the bed at two sites in the western marginal zone of the GrIS. We find a sustained high amount of basal motion contribution to surface velocity of 44-73 percent in winter, and up to 90 percent in summer. Measured ice deformation rates show an unexpected variation with depth that can be explained with the help of an ice-flow model as a consequence of stress transfer from slippery to sticky areas. This effect necessitates the use of high-order ice-flow models, not only in regions of fast-flowing ice streams but in all temperate-based areas of the GrIS. The agreement between modeled and measured deformation rates confirms that the recommended values of the temperature-dependent flow rate factor A are a good choice for ice-sheet models.
NASA Technical Reports Server (NTRS)
Nakamura, S.
1983-01-01
The effects of truncation error on the numerical solution of transonic flows using the full potential equation are studied. The effects of adapting grid point distributions to various solution aspects including shock waves is also discussed. A conclusion is that a rapid change of grid spacing is damaging to the accuracy of the flow solution. Therefore, in a solution adaptive grid application an optimal grid is obtained as a tradeoff between the amount of grid refinement and the rate of grid stretching.
Shakiba, Mohammad; Parson, Nick; Chen, X-Grant
2016-06-30
The hot deformation behavior of Al-0.12Fe-0.1Si alloys with varied amounts of Cu (0.002-0.31 wt %) was investigated by uniaxial compression tests conducted at different temperatures (400 °C-550 °C) and strain rates (0.01-10 s -1 ). The results demonstrated that flow stress decreased with increasing deformation temperature and decreasing strain rate, while flow stress increased with increasing Cu content for all deformation conditions studied due to the solute drag effect. Based on the experimental data, an artificial neural network (ANN) model was developed to study the relationship between chemical composition, deformation variables and high-temperature flow behavior. A three-layer feed-forward back-propagation artificial neural network with 20 neurons in a hidden layer was established in this study. The input parameters were Cu content, temperature, strain rate and strain, while the flow stress was the output. The performance of the proposed model was evaluated using the K-fold cross-validation method. The results showed excellent generalization capability of the developed model. Sensitivity analysis indicated that the strain rate is the most important parameter, while the Cu content exhibited a modest but significant influence on the flow stress.
NASA Astrophysics Data System (ADS)
Yang, Hyeon Sun; Park, Jong Ho; Ra, Ho Won; Jin, Chang-Soo; Yang, Jung Hoon
2016-09-01
In a zinc-bromine redox flow battery, a nonaqueous and dense polybromide phase formed because of bromide oxidation in the positive electrolyte during charging. This formation led to complicated two-phase flow on the electrode surface. The polybromide and aqueous phases led to different kinetics of the Br/Br- redox reaction; poor mixing of the two phases caused uneven redox kinetics on the electrode surface. As the Br/Br- redox reaction was coupled with the zinc deposition reaction, the uneven redox reaction on the positive electrode was accompanied by nonuniform zinc deposition and zinc dendrite formation, which degraded battery stability. A single-flow cell was operated at varying electrolyte circulation rates and current densities. Zinc dendrite formation was observed after cell disassembly following charge-discharge testing. In addition, the flow behavior in the positive compartment was observed by using a transparent version of the cell. At low rate of electrolyte circulation, the polybromide phase clearly separated from the aqueous phase and accumulated at the bottom of the flow frame. In the corresponding area on the negative electrode, a large amount of zinc dendrites was observed after charge-discharge testing. Therefore, a minimum circulation rate should be considered to avoid poor mixing of the positive electrolyte.
Shakiba, Mohammad; Parson, Nick; Chen, X.-Grant
2016-01-01
The hot deformation behavior of Al-0.12Fe-0.1Si alloys with varied amounts of Cu (0.002–0.31 wt %) was investigated by uniaxial compression tests conducted at different temperatures (400 °C–550 °C) and strain rates (0.01–10 s−1). The results demonstrated that flow stress decreased with increasing deformation temperature and decreasing strain rate, while flow stress increased with increasing Cu content for all deformation conditions studied due to the solute drag effect. Based on the experimental data, an artificial neural network (ANN) model was developed to study the relationship between chemical composition, deformation variables and high-temperature flow behavior. A three-layer feed-forward back-propagation artificial neural network with 20 neurons in a hidden layer was established in this study. The input parameters were Cu content, temperature, strain rate and strain, while the flow stress was the output. The performance of the proposed model was evaluated using the K-fold cross-validation method. The results showed excellent generalization capability of the developed model. Sensitivity analysis indicated that the strain rate is the most important parameter, while the Cu content exhibited a modest but significant influence on the flow stress. PMID:28773658
Fukuda, Jun; Iwura, Takafumi; Yanagihara, Shigehiro; Kano, Kenji
2014-10-01
Hollow-fiber-flow field-flow fractionation (HF5) separates protein molecules on the basis of the difference in the diffusion coefficient, and can evaluate the aggregation ratio of proteins. However, HF5 is still a minor technique because information on the separation conditions is limited. We examined in detail the effect of different settings, including the main-flow rate, the cross-flow rate, the focus point, the injection amount, and the ionic strength of the mobile phase, on fractographic characteristics. On the basis of the results, we proposed optimized conditions of the HF5 method for quantification of monoclonal antibody in sample solutions. The HF5 method was qualified regarding the precision, accuracy, linearity of the main peak, and quantitation limit. In addition, the HF5 method was applied to non-heated Mab A and heat-induced-antibody-aggregate-containing samples to evaluate the aggregation ratio and the distribution extent. The separation performance was comparable with or better than that of conventional methods including analytical ultracentrifugation-sedimentation velocity and asymmetric-flow field-flow fractionation.
NASA Astrophysics Data System (ADS)
Ritvanen, J.; Jalali, P.
2009-06-01
Rapid granular shear flow is a classical example in granular materials which exhibits both fluid-like and solid-like behaviors. Another interesting feature of rapid granular shear flows is the formation of ordered structures upon shearing. Certain amount of granular material, with uniform size distribution, is required to be loaded in the container in order to shear it under stable conditions. This work concerns the experimental study of rapid granular shear flows in annular Couette geometry. The flow is induced by continuous rotation of the plate over the top of the granular bed in an annulus. The compressive pressure, driving torque, instantaneous bed height from three symmetric locations and rotational speed of the shearing plate are measured. The annulus has a capacity of up to 15 kg of spherical steel balls of 3 mm in diameter. Rapid shear flow experiments are performed in one compressive force and rotation rate. The sensitivity of fluctuations is then investigated by different means through monodisperse packing. In this work, we present the results of the experiments showing how the flow properties depend on the amount of loaded granular material which is varied by small amounts between different experiments. The flow can exist in stable (fixed behavior) and unstable (time-dependent behavior) regimes as a function of the loaded material. We present the characteristics of flow to detect the formation of any additional structured layer in the annulus. As a result, an evolution graph for the bed height has been obtained as material is gradually added. This graph shows how the bed height grows when material increases. Using these results, the structure inside the medium can be estimated at extreme stable and unstable conditions.
Electricity Cogenerator from Hydrogen and Biogas
NASA Astrophysics Data System (ADS)
Pinate, W.; Chinnasa, P.; Dangphonthong, D.
2017-09-01
This research studied about electricity cogenerator from Hydrogen and Biogas and the factors that cause that effecting Hydrogen from Aluminium which was a cylindrical feature. By using a catalyst was NaOH and CaO, it was reacted in distilled water with percentage of Aluminium: the catalyst (NaOH and CaO) and brought to mix with Biogas afterwards, that have been led to electricity from generator 1 kilowatt. The research outcomes were concentration of solutions that caused amount and percent of maximum Hydrogen was to at 10 % wt and 64.73 % which rate of flowing of constant gas 0.56 litter/minute as temperature 97 degree Celsius. After that led Hydrogen was mixed by Biogas next, conducted to electricity from generator and levelled the voltage of generator at 220 Volt. There after the measure of electricity current and found electricity charge would be constant at 3.1 Ampere. And rate of Biogas flowing and Hydrogen, the result was the generator used Biogas rate of flowing was highest 9 litter/minute and the lowest 7.5 litter/minute, which had rate of flowing around 8.2 litter/minute. Total Biogas was used around 493.2 litter or about 0.493 m3 and Hydrogen had rate of flowing was highest 2.5 litter/minute.
Fukushima, Chizu; Matsuse, Hiroto; Tomari, Shinya; Obase, Yasushi; Miyazaki, Yoshitsugu; Shimoda, Terufumi; Kohno, Shigeru
2003-06-01
Inhaled steroids such as fluticasone propionate and beclomethasone dipropionate play a central role in the treatment of bronchial asthma. Fluticasone exhibits excellent clinical effectiveness; however, oral adverse effects can occur. To compare the frequency of oral candidiasis in asthmatic patients treated with fluticasone and beclomethasone, to evaluate the effect of gargling with amphotericin B, and to measure the inhalation flow rate on candidiasis. The study consisted of 143 asthmatic patients who were treated with inhaled steroids, 11 asthmatic patients not treated with inhaled steroids, and 86 healthy volunteers. Quantitative fungal culture was performed by aseptically obtaining a retropharyngeal wall swab from these patients. Patients with positive results were treated with gargling using a 1:50 dilution amphotericin B solution. In asthmatic patients treated with fluticasone, the inhalation flow rate was measured using an inspiratory flow meter. The amount of Candida spp. was significantly greater in asthmatic patients taking inhaled steroids compared with those who were not. It was also significantly greater in patients with oral symptoms than asymptomatic patients and significantly greater in asthmatic patients treated with fluticasone than in those treated with beclomethasone. Although the presence of Candida did not correlate with the inhaled dose of beclomethasone, it did increase with the dose of fluticasone. Gargling with amphotericin B was effective in most asthmatic patients with candidiasis. Candidiasis was not due to inappropriate flow rates during inhalation of steroids. Fungal culture of a retropharyngeal wall swab may be useful for predicting the risk of developing oral candidiasis in asthmatic patients treated with inhaled steroids. The amount of isolated Candida was significantly greater in asthmatic patients treated with fluticasone than in those treated with beclomethasone. Attention to dosage is required as the amount of Candida increased with dose of fluticasone. Gargling with a 1:50 dilution of amphotericin B is effective in treating oral candidiasis of asthmatic patients treated with inhaled steroids.
Flow measurement in mechanical ventilation: a review.
Schena, Emiliano; Massaroni, Carlo; Saccomandi, Paola; Cecchini, Stefano
2015-03-01
Accurate monitoring of flow rate and volume exchanges is essential to minimize ventilator-induced lung injury. Mechanical ventilators employ flowmeters to estimate the amount of gases delivered to patients and use the flow signal as a feedback to adjust the desired amount of gas to be delivered. Since flowmeters play a crucial role in this field, they are required to fulfill strict criteria in terms of dynamic and static characteristics. Therefore, mechanical ventilators are equipped with only the following kinds of flowmeters: linear pneumotachographs, fixed and variable orifice meters, hot wire anemometers, and ultrasonic flowmeters. This paper provides an overview of these sensors. Their working principles are described together with their relevant advantages and disadvantages. Furthermore, the most promising emerging approaches for flowmeters design (i.e., fiber optic technology and three dimensional micro-fabrication) are briefly reviewed showing their potential for this application. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.
METHOD FOR THE STUDY OF THE LIVER BLOOD FLOW USING GAMMA-EMITTING RADIONUCLIDES
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baptista, A.M.; Carvalho, J.S.
1959-10-31
A method is described for the evaluation of liver blood flow values by radioactivity measurements of gamma-emitting radionuclides, in colloid form, using a scintillation detector positioned over the liver region. It is shown that the disappearance rate constant of the nuclide from the blood can be calculated from the curves obtained. Advantages of the method, including the use of small amounts of radioactive materials, are discussed. (auth)
Robust estimation of simulated urinary volume from camera images under bathroom illumination.
Honda, Chizuru; Bhuiyan, Md Shoaib; Kawanaka, Haruki; Watanabe, Eiichi; Oguri, Koji
2016-08-01
General uroflowmetry method involves the risk of nosocomial infections or time and effort of the recording. Medical institutions, therefore, need to measure voided volume simply and hygienically. Multiple cylindrical model that can estimate the fluid flow rate from the photographed image using camera has been proposed in an earlier study. This study implemented a flow rate estimation by using a general-purpose camera system (Raspberry Pi Camera Module) and the multiple cylindrical model. However, large amounts of noise in extracting liquid region are generated by the variation of the illumination when performing measurements in the bathroom. So the estimation error gets very large. In other words, the specifications of the previous study's camera setup regarding the shutter type and the frame rate was too strict. In this study, we relax the specifications to achieve a flow rate estimation using a general-purpose camera. In order to determine the appropriate approximate curve, we propose a binarizing method using background subtraction at each scanning row and a curve approximation method using RANSAC. Finally, by evaluating the estimation accuracy of our experiment and by comparing it with the earlier study's results, we show the effectiveness of our proposed method for flow rate estimation.
Ghata, Narugopal; Aldredge, Ralph C.; Bec, Julien; Marcu, Laura
2015-01-01
SUMMARY Optical techniques including fluorescence lifetime spectroscopy have demonstrated potential as a tool for study and diagnosis of arterial vessel pathologies. However, their application in the intravascular diagnostic procedures has been hampered by the presence of blood hemoglobin that affects the light delivery to and the collection from the vessel wall. We report a computational fluid dynamics model that allows for the optimization of blood flushing parameters in a manner that minimizes the amount of saline needed to clear the optical field of view and reduces any adverse effects caused by the external saline jet. A 3D turbulence (k−ω) model was employed for Eulerian–Eulerian two-phase flow to simulate the flow inside and around a side-viewing fiber-optic catheter. Current analysis demonstrates the effects of various parameters including infusion and blood flow rates, vessel diameters, and pulsatile nature of blood flow on the flow structure around the catheter tip. The results from this study can be utilized in determining the optimal flushing rate for given vessel diameter, blood flow rate, and maximum wall shear stress that the vessel wall can sustain and subsequently in optimizing the design parameters of optical-based intravascular catheters. PMID:24953876
Quantifying Hydrate Formation in Gas-rich Environments Using the Method of Characteristics
NASA Astrophysics Data System (ADS)
You, K.; Flemings, P. B.; DiCarlo, D. A.
2015-12-01
Methane hydrates hold a vast amount of methane globally, and have huge energy potential. Methane hydrates in gas-rich environments are the most promising production targets. We develop a one-dimensional analytical solution based on the method of characteristics to explore hydrate formation in such environments (Figure 1). Our solution shows that hydrate saturation is constant with time and space in a homogeneous system. Hydrate saturation is controlled by the initial thermodynamic condition of the system, and changed by the gas fractional flow. Hydrate saturation increases with the initial distance from the hydrate phase boundary. Different gas fractional flows behind the hydrate solidification front lead to different gas saturations at the hydrate solidification front. The higher the gas saturation at the front, the less the volume available to be filled by hydrate, and hence the lower the hydrate saturation. The gas fractional flow depends on the relative permeability curves, and the forces that drive the flow. Viscous forces (the drive for flow induced from liquid pressure gradient) dominate the flow, and hydrate saturation is independent on the gas supply rates and the flow directions at high gas supply rates. Hydrate saturation can be estimated as one minus the ratio of the initial to equilibrium salinity. Gravity forces (the drive for flow induced from the gravity) dominate the flow, and hydrate saturation depends on the flow rates and the flow directions at low gas supply rates. Hydrate saturation is highest for upward flow, and lowest for downward flow. Hydrate saturation decreases with the flow rate for upward flow, and increases with the flow rate for downward flow. This analytical solution illuminates how hydrate is formed by gas (methane, CO2, ethane, propane) flowing into brine-saturated sediments at both the laboratory and geological scales (Figure 1). It provides an approach to generalize the understanding of hydrate solidification in gas-rich environments, although complicated numerical models have been developed previously. Examples of gas expulsion into hydrate stability zones and the associated hydrate formation in both laboratory and geological scales, and CO2 sequestration into CO2-hydrates near the seafloor and under the permafrost will be presented.
Performance of high flow rate samplers for respirable particle collection.
Lee, Taekhee; Kim, Seung Won; Chisholm, William P; Slaven, James; Harper, Martin
2010-08-01
The American Conference of Governmental Industrial hygienists (ACGIH) lowered the threshold limit value (TLV) for respirable crystalline silica (RCS) exposure from 0.05 to 0.025 mg m(-3) in 2006. For a working environment with an airborne dust concentration near this lowered TLV, the sample collected with current standard respirable aerosol samplers might not provide enough RCS for quantitative analysis. Adopting high flow rate sampling devices for respirable dust containing silica may provide a sufficient amount of RCS to be above the limit of quantification even for samples collected for less than full shift. The performances of three high flow rate respirable samplers (CIP10-R, GK2.69, and FSP10) have been evaluated in this study. Eleven different sizes of monodisperse aerosols of ammonium fluorescein were generated with a vibrating orifice aerosol generator in a calm air chamber in order to determine the sampling efficiency of each sampler. Aluminum oxide particles generated by a fluidized bed aerosol generator were used to test (i) the uniformity of a modified calm air chamber, (ii) the effect of loading on the sampling efficiency, and (iii) the performance of dust collection compared to lower flow rate cyclones in common use in the USA (10-mm nylon and Higgins-Dewell cyclones). The coefficient of variation for eight simultaneous samples in the modified calm air chamber ranged from 1.9 to 6.1% for triplicate measures of three different aerosols. The 50% cutoff size ((50)d(ae)) of the high flow rate samplers operated at the flow rates recommended by manufacturers were determined as 4.7, 4.1, and 4.8 microm for CIP10-R, GK2.69, and FSP10, respectively. The mass concentration ratio of the high flow rate samplers to the low flow rate cyclones decreased with decreasing mass median aerodynamic diameter (MMAD) and high flow rate samplers collected more dust than low flow rate samplers by a range of 2-11 times based on gravimetric analysis. Dust loading inside the high flow rate samplers does not appear to affect the particle separation in either FSP10 or GK2.69. The high flow rate samplers overestimated compared to the International Standards Organization/Comité Européen de Normalisation/ACGIH respirable convention [up to 40% at large MMAD (27.5 microm)] and could provide overestimated exposure data with the current flow rates. However, both cyclones appeared to be able to provide relatively unbiased assessments of RCS when their flow rates were adjusted.
Performance of High Flow Rate Samplers for Respirable Particle Collection
Lee, Taekhee; Kim, Seung Won; Chisholm, William P.; Slaven, James; Harper, Martin
2010-01-01
The American Conference of Governmental Industrial hygienists (ACGIH) lowered the threshold limit value (TLV) for respirable crystalline silica (RCS) exposure from 0.05 to 0.025 mg m−3 in 2006. For a working environment with an airborne dust concentration near this lowered TLV, the sample collected with current standard respirable aerosol samplers might not provide enough RCS for quantitative analysis. Adopting high flow rate sampling devices for respirable dust containing silica may provide a sufficient amount of RCS to be above the limit of quantification even for samples collected for less than full shift. The performances of three high flow rate respirable samplers (CIP10-R, GK2.69, and FSP10) have been evaluated in this study. Eleven different sizes of monodisperse aerosols of ammonium fluorescein were generated with a vibrating orifice aerosol generator in a calm air chamber in order to determine the sampling efficiency of each sampler. Aluminum oxide particles generated by a fluidized bed aerosol generator were used to test (i) the uniformity of a modified calm air chamber, (ii) the effect of loading on the sampling efficiency, and (iii) the performance of dust collection compared to lower flow rate cyclones in common use in the USA (10-mm nylon and Higgins–Dewell cyclones). The coefficient of variation for eight simultaneous samples in the modified calm air chamber ranged from 1.9 to 6.1% for triplicate measures of three different aerosols. The 50% cutoff size (50dae) of the high flow rate samplers operated at the flow rates recommended by manufacturers were determined as 4.7, 4.1, and 4.8 μm for CIP10-R, GK2.69, and FSP10, respectively. The mass concentration ratio of the high flow rate samplers to the low flow rate cyclones decreased with decreasing mass median aerodynamic diameter (MMAD) and high flow rate samplers collected more dust than low flow rate samplers by a range of 2–11 times based on gravimetric analysis. Dust loading inside the high flow rate samplers does not appear to affect the particle separation in either FSP10 or GK2.69. The high flow rate samplers overestimated compared to the International Standards Organization/Comité Européen de Normalisation/ACGIH respirable convention [up to 40% at large MMAD (27.5 μm)] and could provide overestimated exposure data with the current flow rates. However, both cyclones appeared to be able to provide relatively unbiased assessments of RCS when their flow rates were adjusted. PMID:20660144
Reutilisation-extended material flows and circular economy in China.
Li, Nan; Zhang, Tianzhu; Liang, Sai
2013-06-01
Circular economy (CE), with its basic principle of Reduce, Reuse, and Recycle, has been determined as the key strategy for the national development plan by the Chinese government. Given the economy-wide material flow analysis (EW-MFA) that leaves the inner flow of resource reutilisation unidentified, the reutilisation-extended EW-MFA is first introduced to evaluate and analyse the material input, solid waste generation, and reutilisation simultaneously. The total amount of comprehensive reutilisation (CR) is divided into three sub-flows, namely, reutilisation, recycle, and reuse. Thus, this model is used to investigate the resource CR in China from 2000 to 2010. China's total amount of CR and its sub-flows, as well as the CR rate, remain to have a general upward trend. By the year 2010, about 60% of the overall solid waste generation had already been reutilised, and more than 20% of the total resource requirement was reutilised resource. Moreover, the growth patterns of the CR sub flows show different characteristics. Interpretations of resource reutilisation-related laws and regulations of CE and the corresponding policy suggestions are proposed based on the results. Copyright © 2013 Elsevier Ltd. All rights reserved.
Systematical Optimization of Reverse-phase Chromatography for Shotgun Proteomics
Xu, Ping; Duong, Duc M.; Peng, Junmin
2009-01-01
Summary We report the optimization of a common LC/MS/MS platform to maximize the number of proteins identified from a complex biological sample. The platform uses digested yeast lysate on a 75 μm internal diameter × 12 cm reverse-phase column that is combined with an LTQ-Orbitrap mass spectrometer. We first generated a yeast peptide mix that was quantified by multiple methods including the strategy of stable isotope labeling with amino acids in cell culture (SILAC). The peptide mix was analyzed on a highly reproducible, automated nanoLC/MS/MS system with systematic adjustment of loading amount, flow rate, elution gradient range and length. Interestingly, the column was found to be almost saturated by loading ~1 μg of the sample. Whereas the optimal flow rate (~0.2 μl/min) and elution buffer range (13–32% of acetonitrile) appeared to be independent of the loading amount, the best gradient length varied according to the amount of samples: 160 min for 1 μg of the peptide mix, but 40 min for 10 ng of the same sample. The effect of these parameters on elution peptide peak width is evaluated. After full optimization, 1,012 proteins (clustered in 806 groups) with an estimated protein false discovery rate of ~3% were identified in 1 μg of yeast lysate in a single 160-min LC/MS/MS run. PMID:19566079
NASA Astrophysics Data System (ADS)
Wada, Sanehiro; Furuichi, Noriyuki; Shimada, Takashi
2017-11-01
This paper proposes the application of a novel ultrasonic pulse, called a partial inversion pulse (PIP), to the measurement of the velocity profile and flow rate in a pipe using the ultrasound time-domain correlation (UTDC) method. In general, the measured flow rate depends on the velocity profile in the pipe; thus, on-site calibration is the only method of checking the accuracy of on-site flow rate measurements. Flow rate calculation using UTDC is based on the integration of the measured velocity profile. The advantages of this method compared with the ultrasonic pulse Doppler method include the possibility of the velocity range having no limitation and its applicability to flow fields without a sufficient amount of reflectors. However, it has been previously reported that the measurable velocity range for UTDC is limited by false detections. Considering the application of this method to on-site flow fields, the issue of velocity range is important. To reduce the effect of false detections, a PIP signal, which is an ultrasound signal that contains a partially inverted region, was developed in this study. The advantages of the PIP signal are that it requires little additional hardware cost and no additional software cost in comparison with conventional methods. The effects of inversion on the characteristics of the ultrasound transmission were estimated through numerical calculation. Then, experimental measurements were performed at a national standard calibration facility for water flow rate in Japan. The experimental results demonstrate that measurements made using a PIP signal are more accurate and yield a higher detection ratio than measurements using a normal pulse signal.
Highly Sensitive Hot-Wire Anemometry Based on Macro-Sized Double-Walled Carbon Nanotube Strands.
Wang, Dingqu; Xiong, Wei; Zhou, Zhaoying; Zhu, Rong; Yang, Xing; Li, Weihua; Jiang, Yueyuan; Zhang, Yajun
2017-08-01
This paper presents a highly sensitive flow-rate sensor with carbon nanotubes (CNTs) as sensing elements. The sensor uses micro-size centimeters long double-walled CNT (DWCNT) strands as hot-wires to sense fluid velocity. In the theoretical analysis, the sensitivity of the sensor is demonstrated to be positively related to the ratio of its surface. We assemble the flow sensor by suspending the DWCNT strand directly on two tungsten prongs and dripping a small amount of silver glue onto each contact between the DWCNT and the prongs. The DWCNT exhibits a positive TCR of 1980 ppm/K. The self-heating effect on the DWCNT was observed while constant current was applied between the two prongs. This sensor can evidently respond to flow rate, and requires only several milliwatts to operate. We have, thus far, demonstrated that the CNT-based flow sensor has better sensitivity than the Pt-coated DWCNT sensor.
Pressure independence of granular flow through an aperture.
Aguirre, M A; Grande, J G; Calvo, A; Pugnaloni, L A; Géminard, J-C
2010-06-11
We experimentally demonstrate that the flow rate of granular material through an aperture is controlled by the exit velocity imposed on the particles and not by the pressure at the base, contrary to what is often assumed in previous work. This result is achieved by studying the discharge process of a dense packing of monosized disks through an orifice. The flow is driven by a conveyor belt. This two-dimensional horizontal setup allows us to independently control the velocity at which the disks escape the horizontal silo and the pressure in the vicinity of the aperture. The flow rate is found to be proportional to the belt velocity, independent of the amount of disks in the container and, thus, independent of the pressure in the outlet region. In addition, this specific configuration makes it possible to get information on the system dynamics from a single image of the disks that rest on the conveyor belt after the discharge.
Loyd, S J; Becker, T W; Conrad, C P; Lithgow-Bertelloni, C; Corsetti, F A
2007-09-04
The thermal evolution of Earth is governed by the rate of secular cooling and the amount of radiogenic heating. If mantle heat sources are known, surface heat flow at different times may be used to deduce the efficiency of convective cooling and ultimately the temporal character of plate tectonics. We estimate global heat flow from 65 Ma to the present using seafloor age reconstructions and a modified half-space cooling model, and we find that heat flow has decreased by approximately 0.15% every million years during the Cenozoic. By examining geometric trends in plate reconstructions since 120 Ma, we show that the reduction in heat flow is due to a decrease in the area of ridge-proximal oceanic crust. Even accounting for uncertainties in plate reconstructions, the rate of heat flow decrease is an order of magnitude faster than estimates based on smooth, parameterized cooling models. This implies that heat flow experiences short-term fluctuations associated with plate tectonic cyclicity. Continental separation does not appear to directly control convective wavelengths, but rather indirectly affects how oceanic plate systems adjust to accommodate global heat transport. Given that today's heat flow may be unusually low, secular cooling rates estimated from present-day values will tend to underestimate the average cooling rate. Thus, a mechanism that causes less efficient tectonic heat transport at higher temperatures may be required to prevent an unreasonably hot mantle in the recent past.
Loyd, S. J.; Becker, T. W.; Conrad, C. P.; Lithgow-Bertelloni, C.; Corsetti, F. A.
2007-01-01
The thermal evolution of Earth is governed by the rate of secular cooling and the amount of radiogenic heating. If mantle heat sources are known, surface heat flow at different times may be used to deduce the efficiency of convective cooling and ultimately the temporal character of plate tectonics. We estimate global heat flow from 65 Ma to the present using seafloor age reconstructions and a modified half-space cooling model, and we find that heat flow has decreased by ∼0.15% every million years during the Cenozoic. By examining geometric trends in plate reconstructions since 120 Ma, we show that the reduction in heat flow is due to a decrease in the area of ridge-proximal oceanic crust. Even accounting for uncertainties in plate reconstructions, the rate of heat flow decrease is an order of magnitude faster than estimates based on smooth, parameterized cooling models. This implies that heat flow experiences short-term fluctuations associated with plate tectonic cyclicity. Continental separation does not appear to directly control convective wavelengths, but rather indirectly affects how oceanic plate systems adjust to accommodate global heat transport. Given that today's heat flow may be unusually low, secular cooling rates estimated from present-day values will tend to underestimate the average cooling rate. Thus, a mechanism that causes less efficient tectonic heat transport at higher temperatures may be required to prevent an unreasonably hot mantle in the recent past. PMID:17720806
Review of flow rate estimates of the Deepwater Horizon oil spill.
McNutt, Marcia K; Camilli, Rich; Crone, Timothy J; Guthrie, George D; Hsieh, Paul A; Ryerson, Thomas B; Savas, Omer; Shaffer, Frank
2012-12-11
The unprecedented nature of the Deepwater Horizon oil spill required the application of research methods to estimate the rate at which oil was escaping from the well in the deep sea, its disposition after it entered the ocean, and total reservoir depletion. Here, we review what advances were made in scientific understanding of quantification of flow rates during deep sea oil well blowouts. We assess the degree to which a consensus was reached on the flow rate of the well by comparing in situ observations of the leaking well with a time-dependent flow rate model derived from pressure readings taken after the Macondo well was shut in for the well integrity test. Model simulations also proved valuable for predicting the effect of partial deployment of the blowout preventer rams on flow rate. Taken together, the scientific analyses support flow rates in the range of ∼50,000-70,000 barrels/d, perhaps modestly decreasing over the duration of the oil spill, for a total release of ∼5.0 million barrels of oil, not accounting for BP's collection effort. By quantifying the amount of oil at different locations (wellhead, ocean surface, and atmosphere), we conclude that just over 2 million barrels of oil (after accounting for containment) and all of the released methane remained in the deep sea. By better understanding the fate of the hydrocarbons, the total discharge can be partitioned into separate components that pose threats to deep sea vs. coastal ecosystems, allowing responders in future events to scale their actions accordingly.
Review of flow rate estimates of the Deepwater Horizon oil spill
McNutt, Marcia K.; Camilli, Rich; Crone, Timothy J.; Guthrie, George D.; Hsieh, Paul A.; Ryerson, Thomas B.; Savas, Omer; Shaffer, Frank
2012-01-01
The unprecedented nature of the Deepwater Horizon oil spill required the application of research methods to estimate the rate at which oil was escaping from the well in the deep sea, its disposition after it entered the ocean, and total reservoir depletion. Here, we review what advances were made in scientific understanding of quantification of flow rates during deep sea oil well blowouts. We assess the degree to which a consensus was reached on the flow rate of the well by comparing in situ observations of the leaking well with a time-dependent flow rate model derived from pressure readings taken after the Macondo well was shut in for the well integrity test. Model simulations also proved valuable for predicting the effect of partial deployment of the blowout preventer rams on flow rate. Taken together, the scientific analyses support flow rates in the range of ~50,000–70,000 barrels/d, perhaps modestly decreasing over the duration of the oil spill, for a total release of ~5.0 million barrels of oil, not accounting for BP's collection effort. By quantifying the amount of oil at different locations (wellhead, ocean surface, and atmosphere), we conclude that just over 2 million barrels of oil (after accounting for containment) and all of the released methane remained in the deep sea. By better understanding the fate of the hydrocarbons, the total discharge can be partitioned into separate components that pose threats to deep sea vs. coastal ecosystems, allowing responders in future events to scale their actions accordingly.
Review of flow rate estimates of the Deepwater Horizon oil spill
McNutt, Marcia K.; Camilli, Rich; Crone, Timothy J.; Guthrie, George D.; Hsieh, Paul A.; Ryerson, Thomas B.; Savas, Omer; Shaffer, Frank
2012-01-01
The unprecedented nature of the Deepwater Horizon oil spill required the application of research methods to estimate the rate at which oil was escaping from the well in the deep sea, its disposition after it entered the ocean, and total reservoir depletion. Here, we review what advances were made in scientific understanding of quantification of flow rates during deep sea oil well blowouts. We assess the degree to which a consensus was reached on the flow rate of the well by comparing in situ observations of the leaking well with a time-dependent flow rate model derived from pressure readings taken after the Macondo well was shut in for the well integrity test. Model simulations also proved valuable for predicting the effect of partial deployment of the blowout preventer rams on flow rate. Taken together, the scientific analyses support flow rates in the range of ∼50,000–70,000 barrels/d, perhaps modestly decreasing over the duration of the oil spill, for a total release of ∼5.0 million barrels of oil, not accounting for BP's collection effort. By quantifying the amount of oil at different locations (wellhead, ocean surface, and atmosphere), we conclude that just over 2 million barrels of oil (after accounting for containment) and all of the released methane remained in the deep sea. By better understanding the fate of the hydrocarbons, the total discharge can be partitioned into separate components that pose threats to deep sea vs. coastal ecosystems, allowing responders in future events to scale their actions accordingly. PMID:22187459
Hydrogeology and predevelopment flow in the Texas Gulf Coast aquifer systems
Ryder, Paul D.
1988-01-01
Total simulated recharge in the outcrop areas is 269 million cubic feet per day, which is offset by an equal amount of discharge in the outcrop areas. The smallest rates of leakage are across the Vicksburg-Jackson confining unit, with downward and upward rates of less than one million cubic feet per day. The greatest rate of leakage is 47 million cubic feet per day upward into the Holocene-upper Pleistocene permeable zone.
Liquid phase evaporation on the normal shock wave in moist air transonic flows in nozzles
NASA Astrophysics Data System (ADS)
Dykas, Sławomir; Szymański, Artur; Majkut, Mirosław
2017-06-01
This paper presents a numerical analysis of the atmospheric air transonic flow through de Laval nozzles. By nature, atmospheric air always contains a certain amount of water vapor. The calculations were made using a Laval nozzle with a high expansion rate and a convergent-divergent (CD) "half-nozzle", referred to as a transonic diffuser, with a much slower expansion rate. The calculations were performed using an in-house CFD code. The computational model made it possible to simulate the formation of the liquid phase due to spontaneous condensation of water vapor contained in moist air. The transonic flow calculations also take account of the presence of a normal shock wave in the nozzle supersonic part to analyze the effect of the liquid phase evaporation.
Effect of cell physicochemical characteristics and motility on bacterial transport in groundwater
Becker, M.W.; Collins, S.A.; Metge, D.W.; Harvey, R.W.; Shapiro, A.M.
2004-01-01
The influence of physicochemical characteristics and motility on bacterial transport in groundwater were examined in flow-through columns. Four strains of bacteria isolated from a crystalline rock groundwater system were investigated, with carboxylate-modified and amidine-modified latex microspheres and bromide as reference tracers. The bacterial isolates included a gram-positive rod (ML1), a gram-negative motile rod (ML2), a nonmotile mutant of ML2 (ML2m), and a gram-positive coccoid (ML3). Experiments were repeated at two flow velocities, in a glass column packed with glass beads, and in another packed with iron-oxyhydroxide coated glass beads. Bacteria breakthrough curves were interpreted using a transport equation that incorporates a sorption model from microscopic observation of bacterial deposition in flow-cell experiments. The model predicts that bacterial desorption rate will decrease exponentially with the amount of time the cell is attached to the solid surface. Desorption kinetics appeared to influence transport at the lower flow rate, but were not discernable at the higher flow rate. Iron-oxyhydroxide coatings had a lower-than-expected effect on bacterial breakthrough and no effect on the microsphere recovery in the column experiments. Cell wall type and shape also had minor effects on breakthrough. Motility tended to increase the adsorption rate, and decrease the desorption rate. The transport model predicts that at field scale, desorption rate kinetics may be important to the prediction of bacteria transport rates. ?? 2003 Elsevier B.V. All rights reserved.
Kubota, Chieko; Kanazawa, Manabu; Hama, Yohei; Komagamine, Yuriko; Minakuchi, Shunsuke
2017-10-01
To assess the time course of chewing-stimulated salivary flow after oral atropine administration, and determine the association between chewing-stimulated salivary flow and mixing ability using color-changeable chewing gum in dentate adults. Ten healthy dentate adults were administered 1mg oral atropine to induce mouth dryness. The subjects' chewing-stimulated salivary flow was assessed using the Saxon test. They were then asked to rinse their mouth with tap water for 15s, and to chew on color-changeable chewing gum for 60s at a constant rate of 60 cycles per min. This procedure was performed before, and at 10-min intervals for up to 120min after the atropine administration. The experiment was repeated after 1 week. Steel's test was used to compare the chewing-stimulated salivary flow rates at each time point after atropine administration with the baseline value. The effect of the stimulated salivary flow rates on the degree of color change was analyzed using linear mixed effects models, with the stimulated salivary flow rates as fixed factors and subjects as the random factor. Chewing-stimulated salivary flow showed a significant decrease from 50 to 120min after oral atropine administration (P<0.05) and the amount of chewing-stimulated salivary flow had a significant effect on the color change of the color-changeable chewing gum (P<0.001). We observed a decrease in stimulated salivary flow after orally administering 1mg atropine, and a positive association between mixing ability using color-changeable chewing gum and chewing-stimulated salivary flow in dentate subjects. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.
Pore-scale mechanisms of gas flow in tight sand reservoirs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Silin, D.; Kneafsey, T.J.; Ajo-Franklin, J.B.
2010-11-30
Tight gas sands are unconventional hydrocarbon energy resource storing large volume of natural gas. Microscopy and 3D imaging of reservoir samples at different scales and resolutions provide insights into the coaredo not significantly smaller in size than conventional sandstones, the extremely dense grain packing makes the pore space tortuous, and the porosity is small. In some cases the inter-granular void space is presented by micron-scale slits, whose geometry requires imaging at submicron resolutions. Maximal Inscribed Spheres computations simulate different scenarios of capillary-equilibrium two-phase fluid displacement. For tight sands, the simulations predict an unusually low wetting fluid saturation threshold, at whichmore » the non-wetting phase becomes disconnected. Flow simulations in combination with Maximal Inscribed Spheres computations evaluate relative permeability curves. The computations show that at the threshold saturation, when the nonwetting fluid becomes disconnected, the flow of both fluids is practically blocked. The nonwetting phase is immobile due to the disconnectedness, while the permeability to the wetting phase remains essentially equal to zero due to the pore space geometry. This observation explains the Permeability Jail, which was defined earlier by others. The gas is trapped by capillarity, and the brine is immobile due to the dynamic effects. At the same time, in drainage, simulations predict that the mobility of at least one of the fluids is greater than zero at all saturations. A pore-scale model of gas condensate dropout predicts the rate to be proportional to the scalar product of the fluid velocity and pressure gradient. The narrowest constriction in the flow path is subject to the highest rate of condensation. The pore-scale model naturally upscales to the Panfilov's Darcy-scale model, which implies that the condensate dropout rate is proportional to the pressure gradient squared. Pressure gradient is the greatest near the matrix-fracture interface. The distinctive two-phase flow properties of tight sand imply that a small amount of gas condensate can seriously affect the recovery rate by blocking gas flow. Dry gas injection, pressure maintenance, or heating can help to preserve the mobility of gas phase. A small amount of water can increase the mobility of gas condensate.« less
NASA Astrophysics Data System (ADS)
Rassi, Erik M.; Codd, Sarah L.; Seymour, Joseph D.
2011-01-01
Flow in porous media and the resultant hydrodynamics are important in fields including but not limited to the hydrology, chemical, medical and petroleum industries. The observation and understanding of the hydrodynamics in porous media are critical to the design and optimal utilization of porous media, such as those seen in trickle-bed reactors, medical filters, subsurface flows and carbon sequestration. Magnetic resonance (MR) provides for a non-invasive technique that can probe the hydrodynamics on pore and bulk scale lengths; many previous works have characterized fully saturated porous media, while rapid MR imaging (MRI) methods in particular have previously been applied to partially saturated flows. We present time- and ensemble-averaged MR measurements to observe the effects on a bead pack partially saturated with air under flowing water conditions. The 10 mm internal diameter bead pack was filled with 100 μm borosilicate glass beads. Air was injected into the bead pack as water flowed simultaneously through the sample at 25 ml h-1. The initial partially saturated state was characterized with MRI density maps, free induction decay (FID) experiments, propagators and velocity maps before the water flow rate was increased incrementally from 25 to 500 ml h-1. After the maximum flow rate of 500 ml h-1, the MRI density maps, FID experiments, propagators and velocity maps were repeated and compared to the data taken before the maximum flow rate. This work shows that a partially saturated single-phase flow has global flow dynamics that return to characteristic flow statistics once a steady-state high flow rate has been reached. This high flow rate pushed out a significant amount of the air in the bead pack and caused the return of a preferential flow pattern. Velocity maps indicated that local flow statistics were not the same for the before and after blow out conditions. It has been suggested and shown previously that a flow pattern can return to similar statistics if the preceding flow history is similar.
DNA Molecules in Microfluidic Oscillatory Flow
Chen, Y.-L.; Graham, M.D.; de Pablo, J.J.; Jo, K.; Schwartz, D.C.
2008-01-01
The conformation and dynamics of a single DNA molecule undergoing oscillatory pressure-driven flow in microfluidic channels is studied using Brownian dynamics simulations, accounting for hydrodynamic interactions between segments in the bulk and between the chain and the walls. Oscillatory flow provides a scenario under which the polymers may remain in the channel for an indefinite amount of time as they are stretched and migrate away from the channel walls. We show that by controlling the chain length, flow rate and oscillatory flow frequency, we are able to manipulate the chain extension and the chain migration from the channel walls. The chain stretch and the chain depletion layer thickness near the wall are found to increase as the Weissenberg number increases and as the oscillatory frequency decreases. PMID:19057656
Initial testing of a 3D printed perfusion phantom using digital subtraction angiography
NASA Astrophysics Data System (ADS)
Wood, Rachel P.; Khobragade, Parag; Ying, Leslie; Snyder, Kenneth; Wack, David; Bednarek, Daniel R.; Rudin, Stephen; Ionita, Ciprian N.
2015-03-01
Perfusion imaging is the most applied modality for the assessment of acute stroke. Parameters such as Cerebral Blood Flow (CBF), Cerebral Blood volume (CBV) and Mean Transit Time (MTT) are used to distinguish the tissue infarct core and ischemic penumbra. Due to lack of standardization these parameters vary significantly between vendors and software even when provided with the same data set. There is a critical need to standardize the systems and make them more reliable. We have designed a uniform phantom to test and verify the perfusion systems. We implemented a flow loop with different flow rates (250, 300, 350 ml/min) and injected the same amount of contrast. The images of the phantom were acquired using a Digital Angiographic system. Since this phantom is uniform, projection images obtained using DSA is sufficient for initial validation. To validate the phantom we measured the contrast concentration at three regions of interest (arterial input, venous output, perfused area) and derived time density curves (TDC). We then calculated the maximum slope, area under the TDCs and flow. The maximum slope calculations were linearly increasing with increase in flow rate, the area under the curve decreases with increase in flow rate. There was 25% error between the calculated flow and measured flow. The derived TDCs were clinically relevant and the calculated flow, maximum slope and areas under the curve were sensitive to the measured flow. We have created a systematic way to calibrate existing perfusion systems and assess their reliability.
Literature Review of Low Impact Development for Stormwater Control
2015-05-30
appropriate LID technology can be selected to capture the targeted vi metal pollutant. Little information exists on the effects of field variables such as...loading rates and volume, temperature , climate, pH, sediments, organics, and maintenance cycles on systems in the field. 4. The amount of research...maximum extent technically feasible, the pre-development hydrology of the property with regard to the temperature , rate, volume, and duration of flow
Effects of flow rate on the migration of different plasticizers from PVC infusion medical devices
Eljezi, Teuta; Clauson, Hélène; Lambert, Céline; Bouattour, Yassine; Chennell, Philip; Pereira, Bruno; Sautou, Valérie
2018-01-01
Infusion medical devices (MDs) used in hospitals are often made of plasticized polyvinylchloride (PVC). These plasticizers may leach out into infused solutions during clinical practice, especially during risk-situations, e.g multiple infusions in Intensive Care Units and thus may enter into contact with the patients. The migrability of the plasticizers is dependent of several clinical parameters such as temperature, contact time, nature of the simulant, etc… However, no data is available about the influence of the flow rate at which drug solutions are administrated. In this study, we evaluated the impact of different flow rates on the release of the different plasticizers during an infusion procedure in order to assess if they could expose the patients to more toxic amounts of plasticizers. Migration assays with different PVC infusion sets and extension lines were performed with different flow rates that are used in clinical practice during 1h, 2h, 4h, 8h and 24h, using a lipophilic drug simulant. From a clinical point of view, the results showed that, regardless of the plasticizer, the faster the flow rate, the higher the infused volume and the higher the quantities of plasticizers released, both from infusion sets and extension lines, leading to higher patient exposure. However, physically, there was no significant difference of the migration kinetics linked to the flow rate for a same medical device, reflecting complex interactions between the PVC matrix and the simulant. The migration was especially dependent on the nature and the composition of the medical device. PMID:29474357
NASA Astrophysics Data System (ADS)
Tang, Yik Sau; Chiu, Tin Lok; Tsang, Anderson Chun On; Leung, Gilberto Ka Kit; Chow, Kwok Wing
2016-11-01
Intracranial aneurysm, abnormal swelling of the cerebral artery, can cause massive internal bleeding in the subarachnoid space upon aneurysm rupture, leading to a high mortality rate. Deployment of a flow diverting stent through endovascular technique can obstruct the blood flow into the aneurysm, thus reducing the risk of rupture. Patient-specific models with both bifurcation and sidewall aneurysms have been investigated. Computational fluid dynamics analysis with physiological boundary conditions has been performed. Several hemodynamic parameters including volume flow rate into the aneurysm and the energy (sum of the fluid kinetic and potential energy) loss between the inlet and outlets were analyzed and compared with the surgical outcome. Based on the simulation results, we conjecture that a clinically successful case might imply less blood flow into the aneurysm after stenting, and thus a smaller amount of energy loss in driving the fluid flow in that portion of artery. This study might provide physicians with quantitative information for surgical decision making. (Partial financial support by the Innovation and Technology Support Program (ITS/011/13 & ITS/150/15) of the Hong Kong Special Administrative Region Government)
Pankow, J.F.; Rathbun, R.E.; Zogorski, J.S.
1996-01-01
Large amounts of the 'fuel-oxygenate' compound methyl-tert-butyl ether (MTBE) are currently being used in gasoline to reduce carbon monoxide and ozone in urban air and to boost fuel octane. Because MTBE can be transported to surface waters in various ways, established theory was used to calculate half-lives for MTBE volatilizing from flowing surface waters. Similar calculations were made for benzene as a representative of the 'BTEX' group of compounds (benzene, toluene, ethyl benzene, and the xylenes), and for tert-butyl alcohol (TBA). The calculations were made as a function of the mean flow velocity u (m/day), the mean flow depth h (m), the ambient temperature, and the wind speed. In deep, slow-moving flows, MTBE volatilizes at rates which are similar to those for the BTEX compounds. In shallow, fast-moving flows, MTBE volatilizes more slowly than benzene, though in such flows both MTBE and benzene volatilize quickly enough that these differences may often not have much practical significance. TBA was found to be essentially nonvolatile from water.
Caries prevalence in chronic alcoholics and the relationship to salivary flow rate and pH.
Dukić, Walter; Dobrijević, Tanja Trivanović; Katunarić, Marina; Lesić, Stjepanka
2013-03-01
The aim of this study was to investigate the dental status of alcoholics; to evaluate the relationship of unstimulated and stimulated saliva pH on their decayed/missing/filled teeth (DMFT); and to evaluate the relationship of unstimulated and stimulated salivary flow rate on their DMFT. A cross-sectional study was conducted in patients treated for alcohol dependency (n = 70; mean age 41.7 years) and a control group of non-alcoholics (n = 70; mean age 39.1 years). Examinations for dental caries were conducted using the World Health Organization (WHO) criteria and questionnaires. The correlation between nominal variables was determined using chi2 test (alpha = 0.05). The correlation between interval variables was determined using Pearson's correlation coefficient. The mean DMFT was similar in alcoholics (14.40) and the control group (13.44) (p > 0.05). There was a statistically significant correlation between alcoholism and unstimulated salivary flow rate (p < 0.05), but no relationship on DMFT was recorded. No statistically significant differences were found between alcoholics and controls in terms of stimulated salivary flow rate (p > 0.05) or stimulated salivary flow on DMFT (p > 0.05). There was a statistically significant correlation between alcoholism and the pH value of stimulated saliva (p < 0.01). There was no correlation between the amount of alcohol consumed and the number of carious lesions (p > 0.05). No major differences were found with respect to overall DMFT in alcoholics compared to the control group. Alcoholism and stimulated salivary flow rate showed no correlation. Unstimulated salivary flow rate as well as the pH values of both unstimulated and stimulated saliva, were lower in the alcoholic group.
TiCl4 as a source of TiO2 particles for laser anemometry measurements in hot gas
NASA Technical Reports Server (NTRS)
Weikle, Donald H.; Seasholtz, Richard G.; Oberle, Lawrence G.
1990-01-01
A method of reacting TiCl4 with water saturated gaseous nitrogen (GN2) at the entrance into a high temperature gas flow is described. The TiO2 particles formed are then entrained in the gas flow and used as seed particles for making laser anemometry (LA) measurements of the flow velocity distribution in the hot gas. Scanning electron microscope photographs of the TiO2 particles are shown. Data rate of the LA processor was measured to determine the amount of TiO2 formed. The TiCl4 and mixing gas flow diagram is shown. This work was performed in an open jet burner.
Powder River outlook stays healthy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stremel, K.
1984-08-01
Well drilling activity in Wyoming's Powder River Basin is discussed. Operators are taking advantage of favorable economic advantages to tap the area's multiple pay potential and challenge its high success rate reputation. A significant amount of exploration and development can be expected in the future due to the recent discovery of high-flowing wells.
The oxidation degradation of aromatic compounds
NASA Technical Reports Server (NTRS)
Brezinsky, Kenneth; Glassman, Irvin
1987-01-01
A series of experiments were conducted which focused on understanding the role that the O atom addition to aromatic rings plays in the oxidation of benzene and toluene. Flow reactor studies of the oxidation of toluene gave an indication of the amount of O atoms available during an oxidation and the degree to which the O atom adds to the ring. Flow reactor studies of the oxidation of toluene and benzene to which NO2 was added, have shown that NO2 appears to suppress the formation of O atoms and consequently reduce the amount of phenols and cresols formed by O atom addition. A high temperature pyrolysis study of phenol has confirmed that the major decomposition products are carbon monoxide and cyclopentadiene. A preliminary value for the overall decomposition rate constant was also obtained.
Life and Times of the X-Ray Gas in Elliptical Galaxies
NASA Astrophysics Data System (ADS)
Renzini, Alvio
2000-09-01
The global gas flows in elliptical galaxies are initiated by stellar mass loss and their diagnostics rely on X-ray observations. The flows are controlled by a number of factors, including supernova heating, the depth and shape of the potential well as determined by the amount and distribution of bright and dark matter, AGN fueling and its feedback effects, interaction with the intracluster medium, and star formation. As a result no steady-state solution can satisfactorily describe the complex, evolutionary behavior of the gas flows, which can experience supersonic wind, subsonic outflow, and inflow phases, and transitions between one such flow regime to another. Having identified heating by Type Ia SN's as one of the key factors controlling the flows, constraints on its evolution with cosmological time are derived by considering the total amount of iron contained in whole clusters of galaxies, while the iron abundance in individual galaxy flows can set constraints on the present rate of SNIa's in ellipticals. The central issue of the problem remains the fate of the gas. It is argued that in one way or another, via SN-driven winds, ram pressure stripping, or AGN violent ejection, most of the gas is ultimately expelled from galaxies thus joining the intracluster medium.
Dhillon, Manu; M Raju, Srinivasa; S Mohan, Raviprakash; Tomar, Divya
2016-01-01
Statement of the Problem Treatment with salivary substitutes and stimulation of salivary flow by either mechanical or pharmacologic methods has side effects and only provides symptomatic relief but no long-lasting results. Purpose To assess the effectiveness of extraoral transcutaneous electric nerve stimulation (TENS) as a mean of stimulating salivary function in healthy adult subjects; as well as to determine the gender and age-dependent changes in salivary flow rates of unstimulated and stimulated parotid saliva. Materials and Method Hundred patients were divided into two groups; Group I aged 20-40 and Group II aged ≥ 60 years. The TENS electrode pads were externally placed on the skin overlying the parotid glands. Unstimulated and stimulated parotid saliva was collected for 5 minutes each by using standardized collection techniques. Results Eighty seven of 100 subjects demonstrated increased salivary flow when stimulated via the TENS unit. Ten experienced no increase and 3 experienced a decrease. The mean unstimulated salivary flow rate was 0.01872 ml/min in Group I and 0.0088 ml/min in Group II. The mean stimulated salivary flow rate was 0.03084 ml/min (SD= 0.01248) in Group I, and 0.01556 ml/min (SD 0.0101) in Group II. After stimulation, the amount of salivary flow increased significantly in both groups (p< 0.001). Statistical comparison of the two groups revealed them to be significantly different (p< 0.001), with Group I producing more saliva. Gender-wise, no statistically significant difference was seen among the subjects in Group I (p = 0.148), and those in Group II (p= 0.448). Out of 12 subjects with 0 baseline flows, 7 continued to have no flow. Five subjects observed side effects, although minimal and transient. Conclusion The TENS unit was effective in increasing parotid gland salivary flow in healthy subjects. There was age-related but no gender-related variability in parotid salivary flow rate. PMID:27602390
Dhillon, Manu; M Raju, Srinivasa; S Mohan, Raviprakash; Tomar, Divya
2016-09-01
Treatment with salivary substitutes and stimulation of salivary flow by either mechanical or pharmacologic methods has side effects and only provides symptomatic relief but no long-lasting results. To assess the effectiveness of extraoral transcutaneous electric nerve stimulation (TENS) as a mean of stimulating salivary function in healthy adult subjects; as well as to determine the gender and age-dependent changes in salivary flow rates of unstimulated and stimulated parotid saliva. Hundred patients were divided into two groups; Group I aged 20-40 and Group II aged ≥ 60 years. The TENS electrode pads were externally placed on the skin overlying the parotid glands. Unstimulated and stimulated parotid saliva was collected for 5 minutes each by using standardized collection techniques. Eighty seven of 100 subjects demonstrated increased salivary flow when stimulated via the TENS unit. Ten experienced no increase and 3 experienced a decrease. The mean unstimulated salivary flow rate was 0.01872 ml/min in Group I and 0.0088 ml/min in Group II. The mean stimulated salivary flow rate was 0.03084 ml/min (SD= 0.01248) in Group I, and 0.01556 ml/min (SD 0.0101) in Group II. After stimulation, the amount of salivary flow increased significantly in both groups (p< 0.001). Statistical comparison of the two groups revealed them to be significantly different (p< 0.001), with Group I producing more saliva. Gender-wise, no statistically significant difference was seen among the subjects in Group I (p = 0.148), and those in Group II (p= 0.448). Out of 12 subjects with 0 baseline flows, 7 continued to have no flow. Five subjects observed side effects, although minimal and transient. The TENS unit was effective in increasing parotid gland salivary flow in healthy subjects. There was age-related but no gender-related variability in parotid salivary flow rate.
Specific Impulse Definition for Ablative Laser Propulsion
NASA Technical Reports Server (NTRS)
Herren, Kenneth A.; Gregory, Don A.
2004-01-01
The term "specific impulse" is so ingrained in the field of rocket propulsion that it is unlikely that any fundamental argument would be taken seriously for its removal. It is not an ideal measure but it does give an indication of the amount of mass flow (mass loss/time), as in fuel rate, required to produce a measured thrust over some time period This investigation explores the implications of being able to accurately measure the ablation rate and how the language used to describe the specific impulse results may have to change slightly, and recasts the specific impulse as something that is not a time average. It is not currently possible to measure the ablation rate accurately in real time so it is generally just assumed that a constant amount of material will be removed for each laser pulse delivered The specific impulse dependence on the ablation rate is determined here as a correction to the classical textbook definition.
Study of Jet-Propulsion System Comprising Blower, Burner, and Nozzle
NASA Technical Reports Server (NTRS)
Hall, Eldon W
1944-01-01
A study was made of the performance of a jet-propulsion system composed of an engine-driven blower, a combustion chamber, and a discharge nozzle. A simplified analysis is made of this system for the purpose of showing in concise form the effect of the important design variables and operating conditions on jet thrust, thrust horsepower, and fuel consumption. Curves are presented that permit a rapid evaluation of the performance of this system for a range of operating conditions. The performance for an illustrative case of a power plant of the type under consideration id discussed in detail. It is shown that for a given airplane velocity the jet thrust horsepower depends mainly on the blower power and the amount of fuel burned in the jet; the higher the thrust horsepower is for a given blower power, the higher the fuel consumption per thrust horsepower. Within limits the amount of air pumped has only a secondary effect on the thrust horsepower and efficiency. A lower limit on air flow for a given fuel flow occurs where the combustion-chamber temperature becomes excessive on the basis of the strength of the structure. As the air-flow rate is increased, an upper limit is reached where, for a given blower power, fuel-flow rate, and combustion-chamber size, further increase in air flow causes a decrease in power and efficiency. This decrease in power is caused by excessive velocity through the combustion chamber, attended by an excessive pressure drop caused by momentum changes occurring during combustion.
Non-Newtonian fluid flow over a heterogeneously slippery surface
NASA Astrophysics Data System (ADS)
Haase, A. Sander; Wood, Jeffery A.; Sprakel, Lisette M. J.; Lammertink, Rob G. H.
2015-11-01
The no-slip boundary condition does not always hold. In the past, we have investigated the influence of effective wall slip on interfacial transport for a bubble mattress - a superhydrophobic surface consisting of an array of transverse gas-filled grooves. We proved experimentally that the amount of effective wall slip depends on the bubble protrusion angle and the surface porosity (Karatay et al., PNAS 110, 2013), and predicted that mass transport can be enhanced significantly (Haase et al., Soft Matter 9, 2013). Both studies involve the flow of water. In practise, however, many liquids encountered are non-Newtonian, like blood and polymer solutions. This raises some interesting questions. How does interfacial transport depend on the rheological properties of the liquid? Does the time-scale of the experiment matter? A bubble mattress is a suitable platform to investigate this, due to local variations in shear rate. We predict that for shear-thinning liquids, compared to water, the amount of wall slip can be enhanced considerably, although this depends on the applied flow rate. Experiments are performed to proof this behaviour. Simulations are used to assess what will happen when the characteristic time-scale of the system matches the relaxation time of the visco-elastic liquid. R.G.H.L. acknowledges the European Research Council for the ERC starting grant 307342-TRAM.
Electrogenerative oxidation of lower alcohols to useful products
Meshbesher, Thomas M.
1987-01-01
In the disclosed electrogenerative process for converting alcohols such as ethanol to aldehydes such as acetaldehyde, the alcohol starting material is an aqueous solution containing more than the azeotropic amount of water. Good first-pass conversions (<40% and more typically <50%) are obtained at operating cell voltages in the range of about 80 to about 350 millivolts at ordinary temperatures and pressures by using very high flow rates of alcohol to the exposed anode surface (i.e. the "gas" side of an anode whose other surface is in contact with the electrolyte). High molar flow rates of vaporized aqueous alcohol also help to keep formation of undesired byproducts at a low level.
Barnard, James G; Kahn, David; Cetlin, David; Randolph, Theodore W; Carpenter, John F
2014-03-01
Filtration to remove viruses is one of the single most expensive steps in the production of mAb drug products. Therefore, virus filtration steps should be fully optimized, and any decline in flow rates warrants investigation into the causes of such membrane fouling. In the current study, it was found that freezing and thawing of a mAb bulk drug solution caused a substantial decrease in viral filter membrane flow rate. Freezing and thawing also caused formation of aggregates and particles across a broad size range, including particles that could be detected by microflow imaging (≥1 μm in size). However, removal of these particles offered little protection against flow rate decline during viral filtration. Further investigation revealed that trace amounts of aggregates (ca. 10⁻⁶ of the total mass of protein in solution) approximately 20-40 nm in size were primarily responsible for the observed membrane fouling. © 2014 Wiley Periodicals, Inc. and the American Pharmacists Association.
Modeling macro-and microstructures of Gas-Metal-Arc Welded HSLA-100 steel
NASA Astrophysics Data System (ADS)
Yang, Z.; Debroy, T.
1999-06-01
Fluid flow and heat transfer during gas-metal-arc welding (GMAW) of HSLA-100 steel were studied using a transient, three-dimensional, turbulent heat transfer and fluid flow model. The temperature and velocity fields, cooling rates, and shape and size of the fusion and heat-affected zones (HAZs) were calculated. A continuous-cooling-transformation (CCT) diagram was computed to aid in the understanding of the observed weld metal microstructure. The computed results demonstrate that the dissipation of heat and momentum in the weld pool is significantly aided by turbulence, thus suggesting that previous modeling results based on laminar flow need to be re-examined. A comparison of the calculated fusion and HAZ geometries with their corresponding measured values showed good agreement. Furthermore, “finger” penetration, a unique geometric characteristic of gas-metal-arc weld pools, could be satisfactorily predicted from the model. The ability to predict these geometric variables and the agreement between the calculated and the measured cooling rates indicate the appropriateness of using a turbulence model for accurate calculations. The microstructure of the weld metal consisted mainly of acicular ferrite with small amounts of bainite. At high heat inputs, small amounts of allotriomorphic and Widmanstätten ferrite were also observed. The observed microstructures are consistent with those expected from the computed CCT diagram and the cooling rates. The results presented here demonstrate significant promise for understanding both macro-and microstructures of steel welds from the combination of the fundamental principles from both transport phenomena and phase transformation theory.
Deformation, Fluid Flow and Mantle Serpentinization at Oceanic Transform Faults
NASA Astrophysics Data System (ADS)
Rupke, L.; Hasenclever, J.
2017-12-01
Oceanic transform faults (OTF) and fracture zones have long been hypothesized to be sites of enhanced fluid flow and biogeochemical exchange. In this context, the serpentine forming interaction between seawater and cold lithospheric mantle rocks is particularly interesting. The transformation of peridotite to serpentinite not only leads to hydration of oceanic plates and is thereby an important agent of the geological water cycle, it is also a mechanism of abiotic hydrogen and methane formation, which can support archeal and bacterial communities at the seafloor. Inferring the likely amount of mantle undergoing serpentinization reactions therefore allows estimating the amount of biomass that may be autotrophically produced at and around oceanic transform faults and mid-ocean ridges Here we present results of 3-D geodynamic model simulations that explore the interrelations between deformation, fluid flow, and mantle serpentinization at oceanic transform faults. We investigate how slip rate and fault offset affect the predicted patterns of mantle serpentinization around oceanic transform faults. Global rates of mantle serpentinization and associated H2 production are calculated by integrating the modeling results with plate boundary data. The global additional OTF-related production of H2 is found to be between 6.1 and 10.7 x 1011 mol per year, which is comparable to the predicted background mid-ocean ridge rate of 4.1 - 15.0 x 1011 mol H2/yr. This points to oceanic transform faults as potential sites of intense fluid-rock interaction, where chemosynthetic life could be sustained by serpentinization reactions.
NASA Astrophysics Data System (ADS)
Gunardi, Setiawan, Ezra Putranda
2015-12-01
Indonesia is a country with high risk of earthquake, because of its position in the border of earth's tectonic plate. An earthquake could raise very high amount of damage, loss, and other economic impacts. So, Indonesia needs a mechanism for transferring the risk of earthquake from the government or the (reinsurance) company, as it could collect enough money for implementing the rehabilitation and reconstruction program. One of the mechanisms is by issuing catastrophe bond, `act-of-God bond', or simply CAT bond. A catastrophe bond issued by a special-purpose-vehicle (SPV) company, and then sold to the investor. The revenue from this transaction is joined with the money (premium) from the sponsor company and then invested in other product. If a catastrophe happened before the time-of-maturity, cash flow from the SPV to the investor will discounted or stopped, and the cash flow is paid to the sponsor company to compensate their loss because of this catastrophe event. When we consider the earthquake only, the amount of discounted cash flow could determine based on the earthquake's magnitude. A case study with Indonesian earthquake magnitude data show that the probability of maximum magnitude can model by generalized extreme value (GEV) distribution. In pricing this catastrophe bond, we assumed stochastic interest rate that following the Cox-Ingersoll-Ross (CIR) interest rate model. We develop formulas for pricing three types of catastrophe bond, namely zero coupon bonds, `coupon only at risk' bond, and `principal and coupon at risk' bond. Relationship between price of the catastrophe bond and CIR model's parameter, GEV's parameter, percentage of coupon, and discounted cash flow rule then explained via Monte Carlo simulation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gunardi,; Setiawan, Ezra Putranda
Indonesia is a country with high risk of earthquake, because of its position in the border of earth’s tectonic plate. An earthquake could raise very high amount of damage, loss, and other economic impacts. So, Indonesia needs a mechanism for transferring the risk of earthquake from the government or the (reinsurance) company, as it could collect enough money for implementing the rehabilitation and reconstruction program. One of the mechanisms is by issuing catastrophe bond, ‘act-of-God bond’, or simply CAT bond. A catastrophe bond issued by a special-purpose-vehicle (SPV) company, and then sold to the investor. The revenue from this transactionmore » is joined with the money (premium) from the sponsor company and then invested in other product. If a catastrophe happened before the time-of-maturity, cash flow from the SPV to the investor will discounted or stopped, and the cash flow is paid to the sponsor company to compensate their loss because of this catastrophe event. When we consider the earthquake only, the amount of discounted cash flow could determine based on the earthquake’s magnitude. A case study with Indonesian earthquake magnitude data show that the probability of maximum magnitude can model by generalized extreme value (GEV) distribution. In pricing this catastrophe bond, we assumed stochastic interest rate that following the Cox-Ingersoll-Ross (CIR) interest rate model. We develop formulas for pricing three types of catastrophe bond, namely zero coupon bonds, ‘coupon only at risk’ bond, and ‘principal and coupon at risk’ bond. Relationship between price of the catastrophe bond and CIR model’s parameter, GEV’s parameter, percentage of coupon, and discounted cash flow rule then explained via Monte Carlo simulation.« less
Lärstad, M A E; Torén, K; Bake, B; Olin, A-C
2007-01-01
Exhaled ethane, pentane and isoprene have been proposed as biomarkers of oxidative stress. The objectives were to explore whether ethane, pentane and isoprene are produced within the airways and to explore the effect of different sampling parameters on analyte concentrations. The flow dependency of the analyte concentrations, the concentrations in dead-space and alveolar air after breath-holding and the influence of inhaling purified air on analyte concentrations were investigated. The analytical method involved thermal desorption from sorbent tubes and gas chromatography. The studied group comprised 13 subjects with clinically stable asthma and 14 healthy controls. Ethane concentrations decreased slightly, but significantly, at higher flow rates in subjects with asthma (P = 0.0063) but not in healthy controls. Pentane levels were increased at higher flow rates both in healthy and asthmatic subjects (P = 0.022 and 0.0063 respectively). Isoprene levels were increased at higher flow rates, but only significantly in healthy subjects (P = 0.0034). After breath-holding, no significant changes in ethane levels were observed. Pentane and isoprene levels increased significantly after 20 s of breath-holding. Inhalation of purified air before exhalation resulted in a substantial decrease in ethane levels, a moderate decrease in pentane levels and an increase in isoprene levels. The major fractions of exhaled ethane, pentane and isoprene seem to be of systemic origin. There was, however, a tendency for ethane to be flow rate dependent in asthmatic subjects, although to a very limited extent, suggesting that small amounts of ethane may be formed in the airways.
Influence of clay particles on microfluidic-based preparation of hydrogel composite microsphere
NASA Astrophysics Data System (ADS)
Hong, Joung Sook
2016-05-01
For the successful fabrication of a hydrogel composite microsphere, this study aimed to investigate the influence of clay particles on microsphere formation in a microfluidic device which has flow focusing and a 4.5:1 contraction channel. A poly alginic acid solution (2.0 wt.%) with clay particles was used as the dispersed phase to generate drops in an oil medium, which then merged with drops of a CaCl2 solution for gelation. Drop generations were observed with different flow rates and particles types. When the flow rate increased, drop generation was enhanced and drop size decreased by the build-up of more favorable hydrodynamic flow conditions to detach the droplets. The addition of a small amount of particles insignificantly changed the drop generation behavior even though it reduced interfacial tension and increased the viscosity of the solution. Instead, clays particles significantly affected hydro-gelation depending on the hydrophobicity of particles, which produced further heterogeneity in the shape and size of microsphere.
Sakai, Miho; Hayakawa, Yoshihiro; Funada, Yasuhiro; Ando, Takashi; Fukusaki, Eiichiro; Bamba, Takeshi
2017-09-15
In this study, we propose a novel variable sample injection system based on full-loop injection, named the split-flow sample introduction system, for application in supercritical fluid chromatography (SFC). In this system, the mobile phase is split by the differential pressure between two back pressure regulators (BPRs) after full-loop injection suitable for SFC, and this differential pressure determines the introduction rate. Nine compounds with a wide range of characteristics were introduced with high reproducibility and universality, confirming that a robust variable sample injection system was achieved. We also investigated the control factors of our proposed system. Sample introduction was controlled by the ratio between the column-side pressure drops in splitless and split flow, ΔP columnsideinsplitless and ΔP columnsideinsplit , respectively, where ΔP columnsideinsplitless is related to the mobile phase flow rate and composition and the column resistance. When all other conditions are kept constant, increasing the make-up flow induces an additional pressure drop on the column side of the system, which leads to a reduced column-side flow rate, and hence decreased the amount of sample injected, even when the net pressure drop on the column side remains the same. Thus, sample introduction could be highly controlled at low sample introduction rate, regardless of the introduction conditions. This feature is advantageous because, as a control factor, the solvent in the make-up pump is independent of the column-side pressure drop. Copyright © 2017. Published by Elsevier B.V.
An Ejector Air Intake Design Method for a Novel Rocket-Based Combined-Cycle Rocket Nozzle
NASA Astrophysics Data System (ADS)
Waung, Timothy S.
Rocket-based combined-cycle (RBCC) vehicles have the potential to reduce launch costs through the use of several different air breathing engine cycles, which reduce fuel consumption. The rocket-ejector cycle, in which air is entrained into an ejector section by the rocket exhaust, is used at flight speeds below Mach 2. This thesis develops a design method for an air intake geometry around a novel RBCC rocket nozzle design for the rocket-ejector engine cycle. This design method consists of a geometry creation step in which a three-dimensional intake geometry is generated, and a simple flow analysis step which predicts the air intake mass flow rate. The air intake geometry is created using the rocket nozzle geometry and eight primary input parameters. The input parameters are selected to give the user significant control over the air intake shape. The flow analysis step uses an inviscid panel method and an integral boundary layer method to estimate the air mass flow rate through the intake geometry. Intake mass flow rate is used as a performance metric since it directly affects the amount of thrust a rocket-ejector can produce. The design method results for the air intake operating at several different points along the subsonic portion of the Ariane 4 flight profile are found to under predict mass flow rate by up to 8.6% when compared to three-dimensional computational fluid dynamics simulations for the same air intake.
A QUANTITATIVE STUDY OF THE EVOLUTION OF GASES FROM ELECTRON TUBES AND MATERIALS.
spectrometer, ion pumps, ionization gauges and precision orifices to measure the flow rate of individual gases. It has been used to examine several...amounts comprise about 95% of the gas evolved during cathode conversion and activation. Additional experiments in the dynamic analysis of tube processes are suggested. (Author)
Economic considerations in the use of inhaled anesthetic agents.
Golembiewski, Julie
2010-04-15
To describe the components of and factors contributing to the costs of inhaled anesthesia, basis for quantifying and comparing these costs, and practical strategies for performing pharmacoeconomic analyses and reducing the costs of inhaled anesthetic agents. Inhaled anesthesia can be costly, and some of the variable costs, including fresh gas flow rates and vaporizer settings, are potential targets for cost savings. The use of a low fresh gas flow rate maximizes rebreathing of exhaled anesthetic gas and is less costly than a high flow rate, but it provides less control of the level of anesthesia. The minimum alveolar concentration (MAC) hour is a measure that can be used to compare the cost of inhaled anesthetic agents at various fresh gas flow rates. Anesthesia records provide a sense of patterns of inhaled anesthetic agent use, but the amount of detail can be limited. Cost savings have resulted from efforts to reduce the direct costs of inhaled anesthetic agents, but reductions in indirect costs through shortened times to patient recovery and discharge following the judicious use of these agents are more difficult to demonstrate. The patient case mix, fresh gas flow rates typically used during inhaled anesthesia, availability and location of vaporizers, and anesthesia care provider preferences and practices should be taken into consideration in pharmacoeconomic evaluations and recommendations for controlling the costs of inhaled anesthesia. Understanding factors that contribute to the costs of inhaled anesthesia and considering those factors in pharmacoeconomic analyses and recommendations for use of these agents can result in cost savings.
Czarnecki, John B.; Clark, Brian R.; Stanton, Gregory P.
2003-01-01
The Mississippi River Valley alluvial aquifer is a water-bearing assemblage of gravels and sands that underlies about 32,000 square miles of Missouri, Kentucky, Tennessee, Mississippi, Louisiana, and Arkansas. Because of the heavy demands placed on the aquifer, several large cones of depression have formed in the potentiometric surface, resulting in lower well yields and degraded water quality in some areas. A ground-water flow model of the alluvial aquifer was previously developed for an area covering 3,826 square miles, extending south from the Arkansas River into the southeastern corner of Arkansas, parts of northeastern Louisiana, and western Mississippi. The flow-model results indicated that continued ground-water withdrawals at rates commensurate with those of 1997 could not be sustained indefinitely without causing water levels to decline below half the original saturated thickness of the aquifer. Conjunctive-use optimization modeling was applied to the flow model of the alluvial aquifer to develop withdrawal rates that could be sustained relative to the constraints of critical ground-water area designation. These withdrawal rates form the basis for estimates of sustainable yield from the alluvial aquifer and from rivers specified within the alluvial aquifer model. A management problem was formulated as one of maximizing the sustainable yield from all ground-water and surface-water withdrawal cells within limits imposed by plausible withdrawal rates, and within specified constraints involving hydraulic head and streamflow. Steady-state conditions were selected because the maximized withdrawals are intended to represent sustainable yield of the system (a rate that can be maintained indefinitely).One point along the Arkansas River and one point along Bayou Bartholomew were specified for obtaining surface-water sustainable-yield estimates within the optimization model. Streamflow constraints were specified at two river cells based on average 7-day low flows with 10-year recurrence intervals. Sustainable-yield estimates were affected by the allowable upper limit on withdrawals from wells specified in the optimization model. Withdrawal rates were allowed to increase to 200 percent of the withdrawal rate in 1997. As the overall upper limit is increased, the sustainable yield generally increases. Tests with the optimization model show that without limits on pumping, wells adjacent to sources of water, such as large rivers, would have optimal withdrawal rates that were orders of magnitude larger than rates corresponding to those of 1997. Specifying an upper withdrawal limit of 100 percent of the 1997 withdrawal rate, the sustainable yield from ground water for the entire study area is 70.3 million cubic feet per day, which is about 96 percent of the amount withdrawn in 1997 (73.5 million cubic feet per day). If the upper withdrawal limit is increased to 150 percent of the 1997 withdrawal rate, the sustainable yield from ground water for the entire study area is 80.6 million cubic feet per day, which is about 110 percent of the amount withdrawn in 1997. If the upper withdrawal limit is increased to 200 percent of the 1997 withdrawal rate, the sustainable yield from ground water for the entire study area is 110.2 million cubic feet per day, which is about 150 percent of the amount withdrawn in 1997. Total sustainable yield from the Arkansas River and Bayou Bartholomew is about 4,900 million cubic feet per day, or about 6,700 percent of the amount of ground-water withdrawn in 1997. The large, sustainable yields from surface water represent a potential source of water that could supplement ground water and meet the total water demand. Unmet demand (defined as the difference between the optimized withdrawal rate or sustainable yield, and the anticipated demand) was calculated using different demand rates based on multiples of the 1997-withdrawal rate. Assuming that demand is the 1997 withdrawal rate, and that sustainable-
Czarnecki, John B.; Clark, Brian R.; Reed, Thomas B.
2003-01-01
The Mississippi River Valley alluvial aquifer is a water-bearing assemblage of gravels and sands that underlies about 32,000 square miles of Missouri, Kentucky, Tennessee, Mississippi, Louisiana, and Arkansas. Because of the heavy demands placed on the aquifer, several large cones of depression over 100 feet deep have formed in the potentiometric surface, resulting in lower well yields and degraded water quality in some areas. A ground-water flow model of the alluvial aquifer was previously developed for an area covering 14,104 square miles, extending northeast from the Arkansas River into the northeast corner of Arkansas and parts of southeastern Missouri. The flow model showed that continued ground-water withdrawals at rates commensurate with those of 1997 could not be sustained indefinitely without causing water levels to decline below half the original saturated thickness of the aquifer. To develop estimates of withdrawal rates that could be sustained in compliance with the constraints of critical ground-water area designation, conjunctive-use optimization modeling was applied to the flow model of the alluvial aquifer in northeastern Arkansas. Ground-water withdrawal rates form the basis for estimates of sustainable yield from the alluvial aquifer and from rivers specified within the alluvial aquifer model. A management problem was formulated as one of maximizing the sustainable yield from all ground-water and surface-water withdrawal cells within limits imposed by plausible withdrawal rates, and within specified constraints involving hydraulic head and streamflow. Steady-state flow conditions were selected because the maximized withdrawals are intended to represent sustainable yield of the system (a rate that can be maintained indefinitely). Within the optimization model, 11 rivers are specified. Surface-water diversion rates that occurred in 2000 were subtracted from specified overland flow at the appropriate river cells. Included in these diversions were the planned diversions of 63,339,248 ft3/d for the Bayou Meto project area and 55,078,367 ft3/d for the Grand Prairie project area, which factor in an additional 30 and 40 percent transmission loss, respectively. Streamflow constraints were specified at all 1,165 river cells based on average 7-day minimum flows for 10 years. Sustainable yield for all rivers ranged from 0 (Current, Little Red, and Bayou Meto Rivers) to almost 5 billion cubic feet per day for the Arkansas River. Total sustainable yield from all rivers combined was 12.8 billion cubic feet per day, which represents a substantial source for supplementing ground water to meet the total water demand. Sustainable-yield estimates are affected by the allowable upper limit on withdrawals from wells specified in the optimization model. Ground-water withdrawal rates were allowed to vary as much as 200 percent of the withdrawal rate in 1997. As the overall upper limit on withdrawals is increased, the sustainable yield generally increases. Tests with the optimization model show that without limits on pumping, wells adjacent to sources of water would have optimized withdrawal rates that were orders of magnitude larger than rates corresponding to those of 1997. The sustainable yield from ground water for the entire study area while setting the maximum upper limit as the amount withdrawn in 1997 is 360 million cubic feet per day, which is only about 57 percent of the amount withdrawn in 1997 (635.6 million cubic feet per day). Optimal sustainable yields from within the Bayou Meto irrigation project area and within the Grand Prairie irrigation project area are 18.1 and 9.1 million cubic feet per day, respectively, assuming a maximum allowable withdrawal rate equal to 1997 rates. These values of sustainable yield represent 35 and 30 percent respectively of the amount pumped from these project areas in 1997. Unmet demand (defined as the difference between the optimized withdrawal rate or sustainable yield, a
Process viscometry in flows of non-Newtonian fluids using an anchor agitator
NASA Astrophysics Data System (ADS)
Jo, Hae Jin; Jang, Hye Kyeong; Kim, Young Ju; Hwang, Wook Ryol
2017-11-01
In this work, we present a viscosity measurement technique for inelastic non-Newtonian fluids directly in flows of anchor agitators that are commonly used in highly viscous fluid mixing particularly with yield stress. A two-blade anchor impeller is chosen as a model flow system and Carbopol 940 solutions and Xanthan gum solutions with various concentrations are investigated as test materials. Following the Metzner-Otto correlation, the effective shear rate constant and the energy dissipation rate constant have been estimated experimentally by establishing (i) the relationship between the power number and the Reynolds number using a reference Newtonian fluid and (ii) the proportionality between the effective shear rate and the impeller speed with a reference non-Newtonian fluid. The effective viscosity that reproduces the same amount of the energy dissipation rate, corresponding to that of Newtonian fluid, has been obtained by measuring torques for various impeller speeds and the accuracy in the viscosity prediction as a function of the shear rate has been compared with the rheological measurement. We report that the process viscometry with the anchor impeller yields viscosity estimation within the relative error of 20% with highly shear-thinning fluids.
NASA Astrophysics Data System (ADS)
Baharin, Nuraida'Aadilia; Arzami, Amir Afiq; Singh, Baljit; Remeli, Muhammad Fairuz; Tan, Lippong; Oberoi, Amandeep
2017-04-01
In this study, a thermoelectric generator heat exchanger system was designed and simulated for electricity generation from solar pond. A thermoelectric generator heat exchanger was studied by using Computational Fluid Dynamics to simulate flow and heat transfer. A thermoelectric generator heat exchanger designed for passive in-pond flow used in solar pond for electrical power generation. A simple analysis simulation was developed to obtain the amount of electricity generated at different conditions for hot temperatures of a solar pond at different flow rates. Results indicated that the system is capable of producing electricity. This study and design provides an alternative way to generate electricity from solar pond in tropical countries like Malaysia for possible renewable energy applications.
Thermomagnetic burn control for magnetic fusion reactor
Rawls, J.M.; Peuron, A.U.
1980-07-01
Apparatus is provided for controlling the plasma energy production rate of a magnetic-confinement fusion reactor, by controlling the magnetic field ripple. The apparatus includes a group of shield sectors formed of ferromagnetic material which has a temperature-dependent saturation magnetization, with each shield lying between the plasma and a toroidal field coil. A mechanism for controlling the temperature of the magnetic shields, as by controlling the flow of cooling water therethrough, thereby controls the saturation magnetization of the shields and therefore the amount of ripple in the magnetic field that confines the plasma, to thereby control the amount of heat loss from the plasma. This heat loss in turn determines the plasma state and thus the rate of energy production.
NASA Astrophysics Data System (ADS)
Kordilla, J.; Noffz, T.; Dentz, M.; Sauter, M.
2017-12-01
To assess the vulnerability of an aquifer system it is of utmost importance to recognize the high potential for a rapid mass transport offered by ow through unsaturated fracture networks. Numerical models have to reproduce complex effects of gravity-driven flow dynamics to generate accurate predictions of flow and transport. However, the non-linear characteristics of free surface flow dynamics and partitioning behaviour at unsaturated fracture intersections often exceed the capacity of classical volume-effective modelling approaches. Laboratory experiments that manage to isolate single aspects of the mass partitioning process can enhance the understanding of underlying dynamics, which ultimately influence travel time distributions on multiple scales. Our analogue fracture network consists of synthetic cubes with dimensions of 20 x 20 x 20 cm creating simple geometries of a single or a cascade of consecutive horizontal fractures. Gravity-driven free surface flow (droplets; rivulets) is established via a high precision multichannel dispenser at flow rates ranging from 1.5 to 4.5 ml/min. Single-inlet experiments show the influence of variable flow rate, atmospheric pressure and temperature on the stability of flow modes and allow to delineate a droplet and rivulet regime. The transition between these regimes exhibits mixed flow characteristics. In addition, multi-inlet setups with constant total infow rates decrease the variance induced by erratic free-surface flow dynamics. We investigate the impacts of variable aperture widths, horizontal offsets of vertical fracture surfaces, and alternating injection methods for both flow regimes. Normalized fracture inflow rates allow to demonstrate and compare the effects of variable geometric features. Firstly, the fracture filling can be described by plug flow. At later stages it transitions into a Washburn-type flow, which we compare to an analytical solution for the case of rivulet flow. Observations show a considerably higher bypass effciency of droplet flow. This behaviour may not be recovered by plug flow but also transitions into a Washburn stage. Furthermore, we study the effect of additional cubes, i.e. increasing amount of horizontal fractures, on the bulk arrival times and associated importance of flow mode dependent partitioning processes.
NASA Technical Reports Server (NTRS)
Wang, Q.; Ewing, M. E.; Mathias, E. C.; Heman, J.; Smith, C.; McCool, Alex (Technical Monitor)
2001-01-01
Methodologies have been developed for modeling both gas dynamics and heat transfer inside the carbon fiber rope (CFR) for applications in the space shuttle reusable solid rocket motor joints. Specifically, the CFR is modeled using an equivalent rectangular duct with a cross-section area, friction factor and heat transfer coefficient such that this duct has the same amount of mass flow rate, pressure drop, and heat transfer rate as the CFR. An equation for the friction factor is derived based on the Darcy-Forschheimer law and the heat transfer coefficient is obtained from pipe flow correlations. The pressure, temperature and velocity of the gas inside the CFR are calculated using the one-dimensional Navier-Stokes equations. Various subscale tests, both cold flow and hot flow, have been carried out to validate and refine this CFR model. In particular, the following three types of testing were used: (1) cold flow in a RSRM nozzle-to-case joint geometry, (2) cold flow in a RSRM nozzle joint No. 2 geometry, and (3) hot flow in a RSRM nozzle joint environment simulator. The predicted pressure and temperature history are compared with experimental measurements. The effects of various input parameters for the model are discussed in detail.
A Computer Model for Analyzing Volatile Removal Assembly
NASA Technical Reports Server (NTRS)
Guo, Boyun
2010-01-01
A computer model simulates reactional gas/liquid two-phase flow processes in porous media. A typical process is the oxygen/wastewater flow in the Volatile Removal Assembly (VRA) in the Closed Environment Life Support System (CELSS) installed in the International Space Station (ISS). The volatile organics in the wastewater are combusted by oxygen gas to form clean water and carbon dioxide, which is solved in the water phase. The model predicts the oxygen gas concentration profile in the reactor, which is an indicator of reactor performance. In this innovation, a mathematical model is included in the computer model for calculating the mass transfer from the gas phase to the liquid phase. The amount of mass transfer depends on several factors, including gas-phase concentration, distribution, and reaction rate. For a given reactor dimension, these factors depend on pressure and temperature in the reactor and composition and flow rate of the influent.
NASA Astrophysics Data System (ADS)
Apribowo, Chico Hermanu Brillianto; Ibrahim, Muhammad Hamka; Wicaksono, F. X. Rian
2018-02-01
The growing burden of the load and the complexity of the power system has had an impact on the need for optimization of power system operation. Optimal power flow (OPF) with optimal location placement and rating of thyristor controlled series capacitor (TCSC) is an effective solution used to determine the economic cost of operating the plant and regulate the power flow in the power system. The purpose of this study is to minimize the total cost of generation by placing the location and the optimal rating of TCSC using genetic algorithm-design of experiment techniques (GA-DOE). Simulation on Java-Bali system 500 kV with the amount of TCSC used by 5 compensator, the proposed method can reduce the generation cost by 0.89% compared to OPF without using TCSC.
Silva-Ramos, Miguel; Silva, Isabel; Oliveira, José Carlos; Correia-de-Sá, Paulo
2016-11-01
Diagnosis of bladder outflow obstruction (BOO) in patients with lower urinary tract (LUT) symptoms is challenging without using invasive urodynamic tests. Recently, we showed in vitro that urothelial strips from patients with benign prostatic hyperplasia (BPH) release more ATP than controls. Here, we tested whether urinary ATP can be used as a wall tension transducer non-invasive biomarker to detect BOO in patients with BPH. 79 male patients with BOO and 22 asymptomatic controls were recruited prospectively. Patients were asked to complete the International Prostate Symptom Score (IPSS) questionnaire and to void at normal desire into a urinary flowmeter; the postvoid residual volume was determined by suprapubic ultrasonography. Urine samples from all individuals were examined for ATP, creatinine, and lactate dehydrogenase. BOO patients had significantly higher (P < 0.001) urinary ATP normalized by the voided volume (456 ± 36 nmol) than age-matched controls (209 ± 35 nmol). Urinary ATP amounts increased with the voided volume, but the slope of this rise was higher in BOO patients than in controls. A negative correlation was detected between urinary ATP and flow rate parameters, namely maximal flow rate (r = -0.310, P = 0.005), Siroky flow-volume normalization (r = -0.324, P = 0.004), and volume-normalized flow rate index (r = -0.320, P = 0.012). We found no correlation with LUT symptoms IPSS score. Areas under the receiver operator characteristics (ROC) curves were 0.91 (95%CI 0.86-0.96, P < 0.001) for ATP alone and 0.88 (95%CI 0.81-0.94, P < 0,001) when adjusted to urinary creatinine. Patients with BOO release higher amounts of ATP into the urine than the control group. The high area under the ROC curve suggests that urinary ATP can be a high-sensitive non-invasive biomarker of BOO, which may have a discriminative value of detrusor competence when comparing BPH patients with low urinary flow rates. Prostate 76:1353-1363, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Ito, Yoichiro; Clary, Robert
2016-01-01
High-speed countercurrent chromatography with a spiral tube assembly can retain a satisfactory amount of stationary phase of polymer phase systems used for protein separation. In order to improve the partition efficiency a simple tool to modify the tubing shapes was fabricated, and the following four different tubing modifications were made: intermittently pressed at 10 mm width, flat, flat-wave, and flat-twist. Partition efficiencies of the separation column made from these modified tubing were examined in protein separation with an aqueous-aqueous polymer phase system at flow rates of 1–2 ml/min under 800 rpm. The results indicated that the column with all modified tubing improved the partition efficiency at a flow rate of 1 ml/min, but at a higher flow rate of 2 ml/min the columns made of flattened tubing showed lowered partition efficiency apparently due to the loss of the retained stationary phase. Among all the modified columns, the column with intermittently pressed tubing gave the best peak resolution. It may be concluded that the intermittently pressed and flat-twist improve the partition efficiency in a semi-preparative separation while other modified tubing of flat and flat-wave configurations may be used for analytical separations with a low flow rate. PMID:27790621
Ito, Yoichiro; Clary, Robert
2016-12-01
High-speed countercurrent chromatography with a spiral tube assembly can retain a satisfactory amount of stationary phase of polymer phase systems used for protein separation. In order to improve the partition efficiency a simple tool to modify the tubing shapes was fabricated, and the following four different tubing modifications were made: intermittently pressed at 10 mm width, flat, flat-wave, and flat-twist. Partition efficiencies of the separation column made from these modified tubing were examined in protein separation with an aqueous-aqueous polymer phase system at flow rates of 1-2 ml/min under 800 rpm. The results indicated that the column with all modified tubing improved the partition efficiency at a flow rate of 1 ml/min, but at a higher flow rate of 2 ml/min the columns made of flattened tubing showed lowered partition efficiency apparently due to the loss of the retained stationary phase. Among all the modified columns, the column with intermittently pressed tubing gave the best peak resolution. It may be concluded that the intermittently pressed and flat-twist improve the partition efficiency in a semi-preparative separation while other modified tubing of flat and flat-wave configurations may be used for analytical separations with a low flow rate.
NASA Astrophysics Data System (ADS)
Omar, W. S. A. W.; Sulaiman, A. Z.; Ajit, A.; Chisti, Y.; Chor, A. L. T.
2017-06-01
A full factorial design (FFD) approach was conducted to assess the effect of four factors, namely flow rate, duty cycle, amplitude, and treatment time of ultrasonic regimens towards Escherichia coli harbouring lipase. The 22 experiments were performed as the following values with six replicates of centre point: flow rate (0.1, 0.2, and 0.3 L/min), duty cycle (0, 20, and 40 ), amplitude (2, 6, and 10), and treatment time (10, 35, and 60 min). The FFD was employed as preliminary screening in shake flask cultivation to choose the significant factors (P< 0.05) for further optimisation process. In this study, zero duty cycle signified non-sonication of amplitude and no treatment time effect to the E. coli culture. Also, the designated flow rate and amplitude accordingly showed no effect towards the amount of dry cells weight (DCW). DCW1 was found significantly degraded after the exposure of high duty cycle and treatment time as other factors remained constant. Whereas for the lipase activity, no significant difference was observed in any main factors or interactions. Paired samples t-test confirms the result at a p-value of 0.625. This experimental study suggests the direct and continuous approach of sonication caused an adverse effect on the cells culture density.
Measurements of Flow Rate and Trajectory of Aircraft Tire-Generated Water Spray
NASA Technical Reports Server (NTRS)
Daugherty, Robert H.; Stubbs, Sandy M.
1987-01-01
An experimental investigation was conducted at the NASA Langley Research Center to measure the flow rate and trajectory of water spray generated by an aircraft tire operating on a flooded runway. Tests were conducted in the Hydrodynamics Research Facility and made use of a partial airframe and a nose tire from a general aviation aircraft. Nose tires from a commercial transport aircraft were also used. The effects of forward speed, tire load, and water depth on water spray patterns were evaluated by measuring the amount and location of water captured by an array of tubes mounted behind the test tire. Water ejected from the side of the tire footprint had the most significant potential for ingestion into engine inlets. A lateral wake created on the water surface by the rolling tire can dominate the shape of the spray pattern as the distance aft of the tire is increased. Forward speed increased flow rates and moved the spray pattern inboard. Increased tire load caused the spray to become less dense. Near the tire, increased water depths caused flow rates to increase. Tests using a fuselage and partial wing along with the nose gear showed that for certain configurations, wing aerodynamics can cause a concentration of spray above the wing.
Zhuang, Jie; McCarthy, John F; Tyner, John S; Perfect, Edmund; Flury, Markus
2007-05-01
Colloid transport may facilitate off-site transport of radioactive wastes at the Hanford site, Washington State. In this study, column experiments were conducted to examine the effect of irrigation schedule on releases of in situ colloids from two Hanford sediments during saturated and unsaturated transientflow and its dependence on solution ionic strength, irrigation rate, and sediment texture. Results show that transient flow mobilized more colloids than steady-state flow. The number of short-term hydrological pulses was more important than total irrigation volume for increasing the amount of mobilized colloids. This effect increased with decreasing ionic strength. At an irrigation rate equal to 5% of the saturated hydraulic conductivity, a transient multipulse flow in 100 mM NaNO3 was equivalent to a 50-fold reduction of ionic strength (from 100 mM to 2 mM) with a single-pulse flow in terms of their positive effects on colloid mobilization. Irrigation rate was more important for the initial release of colloids. In addition to water velocity, mechanical straining of colloids was partly responsible for the smaller colloid mobilization in the fine than in the coarse sands, although the fine sand contained much larger concentrations of colloids than the coarse sand.
Linares, Oscar A; Schiesser, William E; Fudin, Jeffrey; Pham, Thien C; Bettinger, Jeffrey J; Mathew, Roy O; Daly, Annemarie L
2015-01-01
There is a need to have a model to study methadone's losses during hemodialysis to provide informed methadone dose recommendations for the practitioner. To build a one-dimensional (1-D), hollow-fiber geometry, ordinary differential equation (ODE) and partial differential equation (PDE) countercurrent hemodialyzer model (ODE/PDE model). We conducted a cross-sectional study in silico that evaluated eleven hemodialysis patients. Patients received a ceiling dose of methadone hydrochloride 30 mg/day. Outcome measures included: the total amount of methadone removed during dialysis; methadone's overall intradialytic mass transfer rate coefficient, km ; and, methadone's removal rate, j ME. Each metric was measured at dialysate flow rates of 250 mL/min and 800 mL/min. The ODE/PDE model revealed a significant increase in the change of methadone's mass transfer with increased dialysate flow rate, %Δkm =18.56, P=0.02, N=11. The total amount of methadone mass transferred across the dialyzer membrane with high dialysate flow rate significantly increased (0.042±0.016 versus 0.052±0.019 mg/kg, P=0.02, N=11). This was accompanied by a small significant increase in methadone's mass transfer rate (0.113±0.002 versus 0.014±0.002 mg/kg/h, P=0.02, N=11). The ODE/PDE model accurately predicted methadone's removal during dialysis. The absolute value of the prediction errors for methadone's extraction and throughput were less than 2%. ODE/PDE modeling of methadone's hemodialysis is a new approach to study methadone's removal, in particular, and opioid removal, in general, in patients with end-stage renal disease on hemodialysis. ODE/PDE modeling accurately quantified the fundamental phenomena of methadone's mass transfer during hemodialysis. This methodology may lead to development of optimally designed intradialytic opioid treatment protocols, and allow dynamic monitoring of outflow plasma opioid concentrations for model predictive control during dialysis in humans.
NASA Astrophysics Data System (ADS)
Chen, Ningsheng; Li, Jun; Liu, Lihong; Yang, Chenglin; Liu, Mei
2018-05-01
This study characterizes significant changes in denudation and disasters in mountainous areas induced in the humid Chengdu Longmenshan region by the Wenchuan Earthquake in 2008. A study focusing on the Longxi-Baisha River Basin was conducted to investigate the amount of denudation triggered by specific flash flood and debris flow events in 2009-2014. The following results were obtained through a comparison of pre-seismic regional denudation rates and denudation characteristics of other seismically active mountain regions. (1) Regional denudation processes occurred in a wave-like process of initial increase then decline, with a peak exhibiting a hyperbolic attenuation trend. This trend indicates that the denudation rate in the Chengdu Longmenshan region is expected to return to the pre-seismic rate of 0.3 mm a-1 after 81 years. In 22 years after the earthquake (Year 2030), debris flow disasters are expected to be rare. (2) Disasters increased significantly in the Chengdu Longmenshan region after the Wenchuan earthquake, with an average of 29.5 people missing or dead per year (22 times greater than the pre-earthquake rate) and average economic losses of 192 million Yuan per year (1.6 times greater than the pre-earthquake rate). (3) The denudation process was jointly controlled by the quantities of loose solid material and precipitation after the Wenchuan earthquake. The amount of loose solid material influenced the extent of denudation, while vegetation coverage rates and soil consolidation determined the overall denudation trend in the region, and changes in precipitation led to denudation fluctuations. (4) The results can be used to analyze the relationship between the potential flash flood-debris flow disasters after earthquakes in the ancient Shu kingdom and changes in historical social settlements. The results can also be used to predict denudation processes and disaster risks from earthquakes in humid mountainous regions around the world, such as the southern slope of the Himalayas, Japan and the Taiwan mountains.
Teare, J P; Spedding, C; Whitehead, M W; Greenfield, S M; Challacombe, S J; Thompson, R P
1995-03-01
Omeprazole causes irreversible inhibition of the hydrogen/potassium adenosine triphosphatase enzyme, leading to a marked reduction in both acid secretion and volume of gastric juice. Reported side-effects include nausea, vomiting, diarrhoea, constipation, and headache. We report the development of dry mouth during omeprazole therapy. We have identified six patients taking omeprazole for more than 6 weeks who complained of a dry mouth. Salivary production was measured as whole salivary flow produced over a 10-min period spat into a collecting vessel and as 5% citric acid-stimulated parotid salivary flow collected with a Lashley cup device placed over the parotid duct. Flow rates were evaluated both during and after cessation of treatment. Saliva produced was then cultured for microbes. Four of the six had subnormal parotid or whole salivary flow rates on treatment that recovered after stopping treatment. The increase after treatment was marked in four. Significant amounts of Candida albicans grew from the saliva of the three patients with the lowest salivary flows; one saliva also grew Staphylococcus aureus. Salivary flow is reduced in some patients treated with omeprazole, returning to normal after cessation of treatment. This reduction may predispose to opportunistic infection, particularly in the edentulous.
NASA Astrophysics Data System (ADS)
Bagnaninchi, P. O.; Yang, Y.; El Haj, A.; Hinds, M. T.; Wang, R. K.
2007-02-01
In order to achieve functional tissue with the correct biomechanical properties it is critical to stimulate mechanically the cells. Perfusion bioreactor induces fluid shear stress that has been well characterized for two-dimensional culture where both simulation and experimental data are available. However these results can't be directly translated to tissue engineering that makes use of complex three-dimensional porous scaffold. Moreover, stimulated cells produce extensive extra-cellular matrix (ECM) that alter dramatically the micro-architecture of the constructs, changing the local flow dynamic. In this study a Fourier domain Doppler optical coherent tomography (FD-DOCT) system working at 1300nm with a bandwidth of 50nm has been used to determine the local flow rate inside different types of porous scaffolds used in tissue engineering. Local flow rates can then be linearly related, for Newtonian fluid, to the fluid shear stress occurring on the pores wall. Porous chitosan scaffolds (\\fgr 1.5mm x 3mm) with and without a central 250 μm microchannel have been produced by a freeze-drying technique. This techniques allow us to determine the actual shear stress applied to the cells and to optimise the input flow rate consequently, but also to relate the change of the flow distribution to the amount of ECM production allowing the monitoring of tissue formation.
Crystal diffraction lens with variable focal length
Smither, R.K.
1991-04-02
A method and apparatus for altering the focal length of a focusing element of one of a plurality of pre-determined focal lengths by changing heat transfer within selected portions of the element by controlled quantities is disclosed. Control over heat transfer is accomplished by manipulating one or more of a number of variables, including: the amount of heat or cold applied to surfaces; type of fluids pumped through channels for heating and cooling; temperatures, directions of flow and rates of flow of fluids; and placement of channels. 19 figures.
Investigation of hollow cathode performance for 30-cm thrusters
NASA Technical Reports Server (NTRS)
Mirtich, M. J.
1973-01-01
A parametric investigation of 6.35 mm diameter mercury hollow cathodes was carried out in a bell jar. The parameters that were varied were the amount of initial emissive mix, insert position, emission current, cathode temperature, orifice diameter, and mercury flow rate. Flow characteristic curves and performance as a function of time were obtained for the various cathodes. The results of a 3880 hr life test of a main cathode run at 15 amps emission current with no noticeable changes in keeper and collector voltages are also presented.
Time-lapse 3D imaging of calcite precipitation in a microporous column
NASA Astrophysics Data System (ADS)
Godinho, Jose R. A.; Withers, Philip J.
2018-02-01
Time-lapse X-ray computed tomography is used to image the evolution of calcite precipitation during flow through microporous quartz over the course of 400 h. The growth rate decreases by more than seven times, which is linked to the clogging of flow paths that restricts flow to some regions of the column. Fewer precipitates are observed as a function of column depth, which is found to be related to a differential nucleation density along the sample. A higher nucleation density closer to the inlet implies more crystal volume increase per unit of time without affecting the rate if normalized to the surface area of crystals. Our overall growth rates measured in porous media are orders of magnitude slower than growth rates derived from traditional precipitation experiments on free surfaces. Based on our time-lapse results we hypothesize a scenario where the evolving distribution of precipitates within a pore structure during precipitation progressively modifies the local transport through the pores. Within less permeable regions the saturation index may be lower than along the main flow paths. Therefore, the reactive crystal surfaces within those regions grow at a slower rate than that expected from the bulk fluid composition. Since the amount of reactive surface area within these less permeable regions increases over time, the overall growth rate decreases without a necessary significant change of the bulk fluid composition along more permeable flow paths. In conclusion, the overall growth rates in an evolving porous media expected from bulk fluid compositions alone can be overestimated due to the development of stagnant sub-regions where the reactive surface area is bath by a solution with lower saturation index. In this context we highlight the value of time-lapse 3D studies for understanding the dynamics of mineral precipitation in porous media.
Generation of Complex Karstic Conduit Networks with a Hydro-chemical Model
NASA Astrophysics Data System (ADS)
De Rooij, R.; Graham, W. D.
2016-12-01
The discrete-continuum approach is very well suited to simulate flow and solute transport within karst aquifers. Using this approach, discrete one-dimensional conduits are embedded within a three-dimensional continuum representative of the porous limestone matrix. Typically, however, little is known about the geometry of the karstic conduit network. As such the discrete-continuum approach is rarely used for practical applications. It may be argued, however, that the uncertainty associated with the geometry of the network could be handled by modeling an ensemble of possible karst conduit networks within a stochastic framework. We propose to generate stochastically realistic karst conduit networks by simulating the widening of conduits as caused by the dissolution of limestone over geological relevant timescales. We illustrate that advanced numerical techniques permit to solve the non-linear and coupled hydro-chemical processes efficiently, such that relatively large and complex networks can be generated in acceptable time frames. Instead of specifying flow boundary conditions on conduit cells to recharge the network as is typically done in classical speleogenesis models, we specify an effective rainfall rate over the land surface and let model physics determine the amount of water entering the network. This is advantageous since the amount of water entering the network is extremely difficult to reconstruct, whereas the effective rainfall rate may be quantified using paleoclimatic data. Furthermore, we show that poorly known flow conditions may be constrained by requiring a realistic flow field. Using our speleogenesis model we have investigated factors that influence the geometry of simulated conduit networks. We illustrate that our model generates typical branchwork, network and anastomotic conduit systems. Flow, solute transport and water ages in karst aquifers are simulated using a few illustrative networks.
Calvet, S; Estellés, F; Cambra-López, M; Torres, A G; Van den Weghe, H F A
2011-11-01
Carbon dioxide balances are useful in determining ventilation rates in livestock buildings. These balances need an accurate estimation of the CO(2) produced by animals and their litter to determine the ventilation flows. To estimate the daily variation in ventilation flow, it is necessary to precisely know the daily variation pattern of CO(2) production, which mainly depends on animal activity. The objective of this study was to explore the applicability of CO(2) balances for determining ventilation flows in broiler buildings. More specifically, this work aimed to quantify the amount of CO(2) produced by the litter, as well as the amount of CO(2) produced by the broilers, as a function of productive parameters, and to analyze the influence of broiler activity on CO(2) emissions. Gas concentrations and ventilation flows were simultaneously measured in 3 trials, with 1 under experimental conditions and the other 2 in a commercial broiler farm. In the experimental assay, broiler activity was also determined. At the end of the experimental trial, on the day after the removal of the broilers, the litter accounted for 20% of the total CO(2) produced, and the broilers produced 3.71 L/h of CO(2) per kg of metabolic weight. On the commercial farm, CO(2) production was the same for the 2 cycles (2.60 L/h per kg of metabolic weight, P > 0.05). However, substantial differences were found between CO(2) and broiler activity patterns after changes in light status. A regression model was used to explain these differences (R(2) = 0.52). Carbon dioxide increased with bird activity, being on average 3.02 L/h per kg of metabolic weight for inactive birds and 4.73 L/h per kg of metabolic weight when bird activity was highest. Overall, CO(2) balances are robust tools for determining the daily average ventilation flows in broiler farms. These balances could also be applied at more frequent intervals, but in this case, particular care is necessary after light status changes because of discrepancy between animal activity and CO(2) production.
Gebert, J; Gröngröft, A
2006-01-01
An upflow biofilter system was operated on a passively vented landfill for the treatment of residual landfill methane. Biofilter methane emissions as a basis for determining methane removal rates were assessed by manual and automated chamber measurements, by measuring methane concentrations in the top layer gaseous phase in combination with gas flow rates, and by evaluating the methane load in the reverse gas flow following the change of landfill gas flux direction as governed by the course of barometric pressure. Methane removal rates were very high with maximum values of 80 g h(-1) m(-3). For the observed cases, the limit of biofilter methane oxidation capacity was not reached and absolute removal rates were thus linearly correlated to the amount of methane entering the filter. The analysis of methane loads flowing back from the biofilter following phases of longer, continuous and non-oscillating landfill gas emission, however, revealed that in these situations biofilter performance is restricted by deficient oxygen supply. At the oxygen-restricted capacity limit, removal rates are influenced by temperature (positively), methane influx (negatively) and flow rate (negatively) as a measure for the displacement of oxygen. These situations, however, account for only 12% of all emission phases. The investigated biofilter capacity, as derived from laboratory analyses of methanotrophic activities, is sufficient to oxidise 62% of the methane load emitted annually. Field and laboratory data provide a stable basis for the dimensioning of filters in future applications.
Relating magnetic reconnection to coronal heating
Longcope, D. W.; Tarr, L. A.
2015-01-01
It is clear that the solar corona is being heated and that coronal magnetic fields undergo reconnection all the time. Here we attempt to show that these two facts are related—i.e. coronal reconnection generates heat. This attempt must address the fact that topological change of field lines does not automatically generate heat. We present one case of flux emergence where we have measured the rate of coronal magnetic reconnection and the rate of energy dissipation in the corona. The ratio of these two, , is a current comparable to the amount of current expected to flow along the boundary separating the emerged flux from the pre-existing flux overlying it. We can generalize this relation to the overall corona in quiet Sun or in active regions. Doing so yields estimates for the contribution to coronal heating from magnetic reconnection. These estimated rates are comparable to the amount required to maintain the corona at its observed temperature. PMID:25897089
Modeling macro-and microstructures of gas-metal-arc welded HSLA-100 steel
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Z.; Debroy, T.
1999-06-01
Fluid flow and heat transfer during gas-metal-arc welding (GMAW) of HSLA-100 steel were studied using a transient, three-dimensional, turbulent heat transfer and fluid flow model. The temperature and velocity fields, cooling rates, and shape and size of the fusion and heat-affected zones (HAZs) were calculated. A continuous-cooling-transformation (CCT) diagram was computed to aid in the understanding of the observed weld metal microstructure. The computed results demonstrate that the dissipation of heat and momentum in the weld pool is significantly aided by turbulence,m thus suggesting that previous modeling results based on laminar flow need to be re-examined. A comparison of themore » calculated fusion and HAZ geometries with their corresponding measured values showed good agreement. Furthermore, finger penetration, a unique geometric characteristic of gas-metal-arc weld pools, could be satisfactorily predicted from the model. The ability to predict these geometric variables and the agreement between the calculated and the measured cooling rates indicate the appropriateness of using a turbulence model for accurate calculations. The microstructure of the weld metal consisted mainly of acicular ferrite with small amounts of bainite. At high heat inputs, small amounts of allotriomorphic and Widmanstaetten ferrite were also observed. The observed microstructures are consistent with those expected from the computed CCT diagram and the cooling rates. The results presented here demonstrate significant promise for understanding both macro-and microstructures of steel welds from the combination of the fundamental principles from both transport phenomena and phase transformation theory.« less
Krivosheeva, Olga; Dėdinaitė, Andra; Linder, Markus B; Tilton, Robert D; Claesson, Per M
2013-02-26
Hydrophobins are relatively small globular proteins produced by filamentous fungi. They display unusual high surface activity and are implied as mediators of attachment to surfaces, which has resulted in high scientific and technological interest. In this work we focus on kinetic and equilibrium aspects of adsorption and desorption properties of two representatives of class II hydrophobins, namely HFBI and HFBII, at a negatively charged hydrophilic solid/water interface and at the air/water interface. The layers formed at the air/liquid interface were examined in a Langmuir trough, whereas layers formed at the solid/liquid interface were studied using dual polarization interferometry (DPI) under different flow conditions. For comparison, another globular protein, lysozyme, was also investigated. It was found that both the adsorbed amount and the adsorption kinetics were different for HFBI and HFBII, and the adsorption behavior of both hydrophobins on the negatively charged surface displayed some unusual features. For instance, even though the adsorption rate for HFBI was slowed down with increasing adsorbed amount as expected from packing constraints at the interface, the adsorption kinetics curves for HFBII displayed a region indicating adsorption cooperativity. Further, it was found that hydrophobin layers formed under flow partly desorbed when the flow was stopped, and the desorption rate for HFBII was enhanced in the presence of hydrophobins in solution.
Ocvirk, Gregor; Hajnsek, Martin; Gillen, Ralph; Guenther, Arnfried; Hochmuth, Gernot; Kamecke, Ulrike; Koelker, Karl-Heinz; Kraemer, Peter; Obermaier, Karin; Reinheimer, Cornelia; Jendrike, Nina; Freckmann, Guido
2009-05-01
A novel microdialysis-based continuous glucose monitoring system, the so-called Clinical Research Tool (CRT), is presented. The CRT was designed exclusively for investigational use to offer high analytical accuracy and reliability. The CRT was built to avoid signal artifacts due to catheter clogging, flow obstruction by air bubbles, and flow variation caused by inconstant pumping. For differentiation between physiological events and system artifacts, the sensor current, counter electrode and polarization voltage, battery voltage, sensor temperature, and flow rate are recorded at a rate of 1 Hz. In vitro characterization with buffered glucose solutions (c(glucose) = 0 - 26 x 10(-3) mol liter(-1)) over 120 h yielded a mean absolute relative error (MARE) of 2.9 +/- 0.9% and a recorded mean flow rate of 330 +/- 48 nl/min with periodic flow rate variation amounting to 24 +/- 7%. The first 120 h in vivo testing was conducted with five type 1 diabetes subjects wearing two systems each. A mean flow rate of 350 +/- 59 nl/min and a periodic variation of 22 +/- 6% were recorded. Utilizing 3 blood glucose measurements per day and a physical lag time of 1980 s, retrospective calibration of the 10 in vivo experiments yielded a MARE value of 12.4 +/- 5.7. Clarke error grid analysis resulted in 81.0%, 16.6%, 0.8%, 1.6%, and 0% in regions A, B, C, D, and E, respectively. The CRT demonstrates exceptional reliability of system operation and very good measurement performance. The ability to differentiate between artifacts and physiological effects suggests the use of the CRT as a reference tool in clinical investigations. 2009 Diabetes Technology Society.
Ocvirk, Gregor; Hajnsek, Martin; Gillen, Ralph; Guenther, Arnfried; Hochmuth, Gernot; Kamecke, Ulrike; Koelker, Karl-Heinz; Kraemer, Peter; Obermaier, Karin; Reinheimer, Cornelia; Jendrike, Nina; Freckmann, Guido
2009-01-01
Background A novel microdialysis-based continuous glucose monitoring system, the so-called Clinical Research Tool (CRT), is presented. The CRT was designed exclusively for investigational use to offer high analytical accuracy and reliability. The CRT was built to avoid signal artifacts due to catheter clogging, flow obstruction by air bubbles, and flow variation caused by inconstant pumping. For differentiation between physiological events and system artifacts, the sensor current, counter electrode and polarization voltage, battery voltage, sensor temperature, and flow rate are recorded at a rate of 1 Hz. Method In vitro characterization with buffered glucose solutions (cglucose = 0 - 26 × 10-3 mol liter-1) over 120 h yielded a mean absolute relative error (MARE) of 2.9 ± 0.9% and a recorded mean flow rate of 330 ± 48 nl/min with periodic flow rate variation amounting to 24 ± 7%. The first 120 h in vivo testing was conducted with five type 1 diabetes subjects wearing two systems each. A mean flow rate of 350 ± 59 nl/min and a periodic variation of 22 ± 6% were recorded. Results Utilizing 3 blood glucose measurements per day and a physical lag time of 1980 s, retrospective calibration of the 10 in vivo experiments yielded a MARE value of 12.4 ± 5.7. Clarke error grid analysis resulted in 81.0%, 16.6%, 0.8%, 1.6%, and 0% in regions A, B, C, D, and E, respectively. Conclusion The CRT demonstrates exceptional reliability of system operation and very good measurement performance. The ability to differentiate between artifacts and physiological effects suggests the use of the CRT as a reference tool in clinical investigations. PMID:20144284
Effects of Distortion on Mass Flow Plug Calibration
NASA Technical Reports Server (NTRS)
Sasson, Jonathan; Davis, David O.; Barnhart, Paul J.
2015-01-01
A numerical, and experimental investigation to study the effects of flow distortion on a Mass Flow Plug (MFP) used to control and measure mass-flow during an inlet test has been conducted. The MFP was first calibrated using the WIND-US flow solver for uniform (undistorted) inflow conditions. These results are shown to compare favorably with an experimental calibration under similar conditions. The effects of distortion were investigated by imposing distorted flow conditions taken from an actual inlet test to the inflow plane of the numerical simulation. The computational fluid dynamic (CFD) based distortion study only showed the general trend in mass flow rate. The study used only total pressure as the upstream boundary condition, which was not enough to define the flow. A better simulation requires knowledge of the turbulence structure and a specific distortion pattern over a range of plug positions. It is recommended that future distortion studies utilize a rake with at least the same amount of pitot tubes as the AIP rake.
Mega debris flow deposits on the western Wilkes Land margin, East Antarctica
Donda, F.; O'Brien, P.E.; De Santis, L.; Rebesco, M.; Brancolini, Giuliano
2007-01-01
Multichannel seismic data collected off Western Wilkes Land (East Antarctica) reveal the occurrence of mega debris flow deposits on the lower slope and rise that were formed throughout the Miocene. Commonly, debris flow units are separated by thin deposits of well-stratified facies, interpreted as predominantly glaciomarine mixed contouritic and distal turbidite deposits. These units could act as weak layers and could have played a major role in the slope instability. High sedimentation rates, due to large amounts of sediment delivered from a temperate, wet-based ice sheet, constituted a key factor in the sediment failures. The main trigger mechanism would probably have been earthquakes enhanced by isostatic rebound following major ice sheet retreats.
Flow and axial dispersion in a sinusoidal-walled tube: Effects of inertial and unsteady flows
DOE Office of Scientific and Technical Information (OSTI.GOV)
Richmond, Marshall C.; Perkins, William A.; Scheibe, Timothy D.
2013-12-01
Dispersion in porous media flows has been the subject of much experimental, theoretical and numerical study. Here we consider a wavy-walled tube (a three-dimensional tube with sinusoidally-varying diameter) as a simplified conceptualization of flow in porous media, where constrictions represent pore throats and expansions pore bodies. A theoretical model for effective (macroscopic) longitudinal dispersion in this system has been developed by volume averaging the microscale velocity field. Direct numerical simulation using computational fluid dynamics (CFD) methods was used to compute velocity fields by solving the Navier-Stokes equations, and also to numerically solve the volume averaging closure problem, for a rangemore » of Reynolds numbers (Re) spanning the low-Re to inertial flow regimes, including one simulation at Re = 449 for which unsteady flow was observed. Dispersion values were computed using both the volume averaging solution and a random walk particle tracking method, and results of the two methods were shown to be consistent. Our results are compared to experimental measurements of dispersion in porous media and to previous theoretical results for the low-Re, Stokes flow regime. In the steady inertial regime we observe an power-law increase in effective longitudinal dispersion (DL) with Re, consistent with previous results. This rapid rate of increase is caused by trapping of solute in expansions due to flow separation (eddies). For the unsteady case (Re = 449), the rate of increase of DL with Re was smaller than that observed at lower Re. Velocity fluctuations in this regime lead to increased rates of solute mass transfer between the core flow and separated flow regions, thus diminishing the amount of tailing caused by solute trapping in eddies and thereby reducing longitudinal dispersion.« less
Ecosystem warming increases sap flow rates of northern red oak trees
Juice, Stephanie M.; Templer, Pamela H.; Phillips, Nathan G.; ...
2016-03-17
Over the next century, air temperature increases up to 5°C are projected for the northeastern United States. As evapotranspiration strongly influences water loss from terrestrial ecosystems, the ecophysiological response of trees to warming will have important consequences for forest water budgets. We measured growing season sap flow rates in mature northern red oak ( Quercus rubra L.) trees in a combined air (up to 5.5°C above ambient) and soil (up to 1.85°C above ambient at 6-cm depth) warming experiment at Harvard Forest, Massachusetts, United States. Through principal components analysis, we found air and soil temperatures explained the largest amount ofmore » variance in environmental variables associated with rates of sap flow, with relative humidity, photosynthetically active radiation and vapor pressure deficit having significant, but smaller, effects. On average, each 1°C increase in temperature increased sap flow rates by approximately 1100 kg H 2O m -2 sapwood area day-1 throughout the growing season and by 1200 kg H 2O m -2 sapwood area day -1 during the early growing season. Reductions in the number of cold winter days correlated positively with increased sap flow during the early growing season (a decrease in 100 heating-degree days was associated with a sapflow increase in approximately 5 kg H 2O m -2 sapwood area day -1). Soil moisture declined with increased treatment temperatures, and each soil moisture percentage decrease resulted in a decrease in sap flow of approximately 360 kg H2O m -22 sapwood area day -1. At night, soil moisture correlated positively with sap flow. Finally, these results demonstrate that warmer air and soil temperatures in winter and throughout the growing season lead to increased sap flow rates, which could affect forest water budgets throughout the year.« less
Ecosystem warming increases sap flow rates of northern red oak trees
DOE Office of Scientific and Technical Information (OSTI.GOV)
Juice, Stephanie M.; Templer, Pamela H.; Phillips, Nathan G.
Over the next century, air temperature increases up to 5°C are projected for the northeastern United States. As evapotranspiration strongly influences water loss from terrestrial ecosystems, the ecophysiological response of trees to warming will have important consequences for forest water budgets. We measured growing season sap flow rates in mature northern red oak ( Quercus rubra L.) trees in a combined air (up to 5.5°C above ambient) and soil (up to 1.85°C above ambient at 6-cm depth) warming experiment at Harvard Forest, Massachusetts, United States. Through principal components analysis, we found air and soil temperatures explained the largest amount ofmore » variance in environmental variables associated with rates of sap flow, with relative humidity, photosynthetically active radiation and vapor pressure deficit having significant, but smaller, effects. On average, each 1°C increase in temperature increased sap flow rates by approximately 1100 kg H 2O m -2 sapwood area day-1 throughout the growing season and by 1200 kg H 2O m -2 sapwood area day -1 during the early growing season. Reductions in the number of cold winter days correlated positively with increased sap flow during the early growing season (a decrease in 100 heating-degree days was associated with a sapflow increase in approximately 5 kg H 2O m -2 sapwood area day -1). Soil moisture declined with increased treatment temperatures, and each soil moisture percentage decrease resulted in a decrease in sap flow of approximately 360 kg H2O m -22 sapwood area day -1. At night, soil moisture correlated positively with sap flow. Finally, these results demonstrate that warmer air and soil temperatures in winter and throughout the growing season lead to increased sap flow rates, which could affect forest water budgets throughout the year.« less
Tracking the hidden growth of a lava flow field: the 2014-15 eruption of Fogo volcano (Cape Verde)
NASA Astrophysics Data System (ADS)
Silva, Sonia; Calvari, Sonia; Hernandez, Pedro; Perez, Nemesio; Ganci, Gaetana; Alfama, Vera; Barrancos, José; Cabral, Jeremias; Cardoso, Nadir; Dionis, Samara; Fernandes, Paulo; Melian, Gladys; Pereira, José; Semedo, Hélio; Padilla, German; Rodriguez, Fatima
2017-04-01
Fogo volcano erupted in 2014-15 producing an extensive lava flow field in the summit caldera that destroyed two villages, Portela and Bangaeira. The eruption started with powerful explosive activity, lava fountaining, and a substantial ash column accompanying the opening of an eruptive fissure. Lava flows spreading from the base of the eruptive fissure produced three arterial lava flows, spreading S (Flow 1), N-NW (Flow 2) and W (Flow 3). By a week after the start of the eruption, a master lava tube had already developed within the eruptive fissure and along Flow 2. When Flow 2 front stopped against the N caldera cliff, the whole flow field behind it inflated, and eventually its partial drainage produced a short tube that fed Flow 3, but no lava tube formed within Flow 1. Here we analyze the emplacement processes on the basis of observations carried out directly on the lava flow field and through satellite image, in order to unravel the key factors leading to the development of lava tubes. These tubes were responsible for the rapid expansion of lava for the 7.9 km length of the flow field, as well as the destruction of the Portela and Bangaeira villages. Comparing time-averaged effusion rates (TADR) obtained from satellite and Supply Rate (SR) derived from SO2 flux data, we estimate the amount and timing of the lava flow field endogenous growth, with the aim of developing a tool that could be used for risk mitigation at this and other volcanoes.
Slugging Flow of Water Draining from the Bottom of a Non-Vented Container
DOE Office of Scientific and Technical Information (OSTI.GOV)
Charles W. Solbrig
2010-06-01
Experiments were run to observe the behavior of water exiting through an orifice at the bottom of an non-vented container. Initially, the container is nearly full of water with a small air space on top. Once the orifice was uncovered, the slugging rate and the drain rate of the water leaving the container were measured. Upon initially opening the orifice, water drains out until the air pressure above the water reduces enough that the air pressure drop from inside to outside of the container supports the water column and the water stops flowing. Air then enters the container through themore » orifice forming a bubble, which grows until it detaches and bubbles through the water to reach the air space. Once the bubble enters, this added air increases the pressure in the air space enough to allow the water to start flowing out again. This cycle of flow out, flow stoppage, air inflow, and bubble breakoff continues over and over until the hole is closed or the container empties. This is referred to as the “slugging cycle.” A mechanism is proposed to describe the slugging cycle which is modeled analytically. This paper presents the description of the experiments, data obtained, the mechanistic model, and comparison of the model to the experimental data. The model predicts outflow rates close to experimental values. Flow rates from non-vented containers are more than 10 to 20 less than vented containers. The bubbles which must enter the container periodically to increase the internal air pressure stop the water flow momentarily so are responsible for this large decrease in flow rate. Swirl induced in the non-vented container causes the flow rates to increase by a factor of two. The flow rate out of a non-vented container is independent of water height which is in direct contrast to a vented container where the flow rate is proportional to the square root of the water height. The constant rate is due to the container pressure. The higher the water level, the lower the air pressure is in the container. This analytical model requires input of the bubble size. The volume recommended is the volume of a cylinder with the base of the orifice area and length of 3.3 cm. Slugging rate varies only a small amount falling in the range to 2 to 4 cycles/sec. Preliminary work with other containers indicates larger containers, larger orifices and nozzle exit shapes produce higher specific flow rates. The standard multiphase flow equations could not be used to analyze this situation because the two phases are not interpenetrating. Instead one phase must fully stop before the other can flow. Interpenetrating phases allow can pass one another each affecting the other with friction and virtual mass. An interesting observation: The negative air pressure in the container is observable. It equals the water height.« less
Assessment of the viability of skin grafts
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wahner, H.W.
1988-07-01
A number of tests are available to monitor the blood flow in free and distant pedicle skin grafts. The information from these tests aids in the development of measures to enhance vascularization and is occasionally needed to make clinical decisions in patients with distant pedicle grafts. Measurements of the disappearance of an intradermally injected small amount of /sup 133/Xe allows determination of a clearance rate and blood flow before and after clamping the original blood supply through the base. With /sup 99m/Tc, which is generally more readily available, a flow index and block index can be determined. Clinically both proceduresmore » give equally good results in determining a safe time for pedicle base separation. The fluorescein test allows assessment of regional blood flow distribution within the pedicle.« less
Thermomagnetic burn control for magnetic fusion reactor
Rawls, John M.; Peuron, Unto A.
1982-01-01
Apparatus is provided for controlling the plasma energy production rate of a magnetic-confinement fusion reactor, by controlling the magnetic field ripple. The apparatus includes a group of shield sectors (30a, 30b, etc.) formed of ferromagnetic material which has a temperature-dependent saturation magnetization, with each shield lying between the plasma (12) and a toroidal field coil (18). A mechanism (60) for controlling the temperature of the magnetic shields, as by controlling the flow of cooling water therethrough, thereby controls the saturation magnetization of the shields and therefore the amount of ripple in the magnetic field that confines the plasma, to thereby control the amount of heat loss from the plasma. This heat loss in turn determines the plasma state and thus the rate of energy production.
[Economic aspects of migration: remittances by migrant workers].
Prskawetz, A
1995-01-01
"Worldwide annual remittances...by migrant workers to their home countries amount to some 70 billion U.S. dollars, exceeded by oil export earnings only.... The amount of remittances depends on the income of both the migrants and their family members.... Remittances meant for investment at home are determined by interest rates, foreign exchange regulations, exchange rates, monetary stability etc. in the immigration and emigration countries. Home remittances and saving habits of emigrants also depend on whether or not they expect to return to their home countries and the prospects of family reunification, all of which is directly linked to the (immigration) policy and economic conditions of both the countries of origin and residence." The factors influencing remittances flowing into and out of Austria are analyzed using data from the Austrian National Bank. (EXCERPT)
A Continuous Method for Gene Flow
Palczewski, Michal; Beerli, Peter
2013-01-01
Most modern population genetics inference methods are based on the coalescence framework. Methods that allow estimating parameters of structured populations commonly insert migration events into the genealogies. For these methods the calculation of the coalescence probability density of a genealogy requires a product over all time periods between events. Data sets that contain populations with high rates of gene flow among them require an enormous number of calculations. A new method, transition probability-structured coalescence (TPSC), replaces the discrete migration events with probability statements. Because the speed of calculation is independent of the amount of gene flow, this method allows calculating the coalescence densities efficiently. The current implementation of TPSC uses an approximation simplifying the interaction among lineages. Simulations and coverage comparisons of TPSC vs. MIGRATE show that TPSC allows estimation of high migration rates more precisely, but because of the approximation the estimation of low migration rates is biased. The implementation of TPSC into programs that calculate quantities on phylogenetic tree structures is straightforward, so the TPSC approach will facilitate more general inferences in many computer programs. PMID:23666937
Mauad, Cristiane R; Wagener, Angela de L R; Massone, Carlos G; Aniceto, Mayara da S; Lazzari, Letícia; Carreira, Renato S; Farias, Cássia de O
2015-02-15
Aliphatic (n-C12-n-C40, unresolved complex mixture, resolved peaks) and aromatic hydrocarbons (46 PAH) were investigated in suspended particulate matter (SPM) sampled over eleven months in six of the major rivers and two channels of the Guanabara Bay Basin. PAH flow rates of the most contaminated rivers, the contribution to the PAH sediment load of the receiving bay, and the main sources of hydrocarbons were determined. PAH (38) ranged from 28 ng L(-1) to 11,514 ng L(-1). Hydrocarbon typology and statistical evaluation demonstrated contribution of distinct sources in different regions and allowed quantification of these contributions. Total flow rate for the five major rivers amounts to 3 t year(-1) and responds for 30% of the total PAH annual input into the northern area of the Guanabara Bay. For the first time PAH mass deposited in the bay sediments has been estimated and shall serve as base for decision making and source abatement. Copyright © 2014 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
C. Withers; Cummings, J.; Nigusse, B.
A new generation of full variable-capacity, central, ducted air-conditioning (AC) and heat pump units has come on the market, and they promise to deliver increased cooling (and heating) efficiency. They are controlled differently than standard single-capacity (fixed-capacity) systems. Instead of cycling on at full capacity and then cycling off when the thermostat is satisfied, they can vary their capacity over a wide range (approximately 40% to 118% of nominal full capacity), thus staying “on” for up to twice as many hours per day compared to fixed-capacity systems of the same nominal capacity. The heating and cooling capacity is varied bymore » adjusting the indoor fan air flow rate, compressor, and refrigerant flow rate as well as the outdoor unit fan air flow rate. Note that two-stage AC or heat pump systems were not evaluated in this research effort. The term dwell is used to refer to the amount of time distributed air spends inside ductwork during space-conditioning cycles. Longer run times mean greater dwell time and therefore greater exposure to conductive gains and losses.« less
Zhang, Shihong; Yang, Mingfa; Shao, Jingai; Yang, Haiping; Zeng, Kuo; Chen, Yingquan; Luo, Jun; Agblevor, Foster A; Chen, Hanping
2018-07-01
Light olefins are the key building blocks for the petrochemical industry. In this study, the effects of in-situ and ex-situ process, temperature, Fe loading, catalyst to feed ratio and gas flow rate on the olefins carbon yield and selectivity were explored. The results showed that Fe-modified ZSM-5 catalyst increased the olefins yield significantly, and the ex-situ process was much better than in-situ. With the increasing of temperature, Fe-loading amount, catalyst to feed ratio, and gas flow rate, the carbon yields of light olefins were firstly increased and further decreased. The maximum carbon yield of light olefins (6.98% C-mol) was obtained at the pyrolysis temperature of 600°C, catalyst to feed ratio of 2, gas flow rate of 100ml/min, and 3wt% Fe/ZSM-5 for cellulose. The selectivity of C 2 H 4 was more than 60% for all feedstock, and the total light olefins followed the decreasing order of cellulose, corn stalk, hemicelluloses and lignin. Copyright © 2018 Elsevier B.V. All rights reserved.
Bio-oil production from fast pyrolysis of waste furniture sawdust in a fluidized bed.
Heo, Hyeon Su; Park, Hyun Ju; Park, Young-Kwon; Ryu, Changkook; Suh, Dong Jin; Suh, Young-Woong; Yim, Jin-Heong; Kim, Seung-Soo
2010-01-01
The amount of waste furniture generated in Korea was over 2.4 million tons in the past 3 years, which can be used for renewable energy or fuel feedstock production. Fast pyrolysis is available for thermo-chemical conversion of the waste wood mostly into bio-oil. In this work, fast pyrolysis of waste furniture sawdust was investigated under various reaction conditions (pyrolysis temperature, particle size, feed rate and flow rate of fluidizing medium) in a fluidized-bed reactor. The optimal pyrolysis temperature for increased yields of bio-oil was 450 degrees C. Excessively smaller or larger feed size negatively affected the production of bio-oil. Higher flow and feeding rates were more effective for the production of bio-oil, but did not greatly affect the bio-oil yields within the tested ranges. The use of product gas as the fluidizing medium had a potential for increased bio-oil yields.
NASA Astrophysics Data System (ADS)
Nakayama, Akifumi; Abe, Yutaka
2015-12-01
Terrestrial planets with several wt% of H2O in extrasolar planetary systems are theoretically predicted in the habitable zone [Raymond et al., 2004]. Such planets are expected to be covered by an ocean entirely (called as “ocean planets”). Amount of atmospheric CO2 (PCO2) is important for surface environment because CO2 is a strong greenhouse gas. PCO2 is determined by a race between degassing and sink through weathering on carbon cycle. On an ocean planet, seafloor weathering is important because continental weathering can’t work [Abbot et al., 2012]. In addition, ocean planets with large water amount may have high-pressure (HP) ice on the seafloor [Leger et al., 2004]. Since the ocean floor is covered by ice in such case, it has been thought that any weathering processes will not work and PCO2 will be extremely high. When plate tectonics works, heat flow from oceanic crust decreases with distance from the mid ocean ridge. Therefore, HP ice near the mid ocean ridge will be kept solid-liquid coexistent state at the melting point because of high heat flow. Seafloor weathering works in this region. The seafloor weathering under this condition efficiently works because weathering temperature is kept melting point regardless of surface temperature. Thus, our aim is to clarify the relationship between water amount and surface environment focusing seafloor environment. We develop a carbon cycle model considering the seafloor weathering. Our major assumptions are following; 1) Earth-sized ocean planets with various water amount, 2) Degassing rate is depended on the total amount of carbon and total carbon inventory is proportional to the surface water amount. We investigated thermal state of HP ice and determined effective weathering region where HP ice is coexistent with water, then we investigated the PCO2 in equilibrium state where degassing and regassing are balanced. As a result, forming of HP ice may cause snowball state due to high weathering rate. When solar incident flux and heat flow from mantle are the present Earth’s value and a ratio of CO2 / H2O inventory is carbonaceous chondrite composition, a planet with large ocean which is larger than 90 Earth’s ocean mass lapses into snowball state. It was previously believed that forming of HP ice supports warm climate; rather, forming of HP ice could cause snowball state.
Method and apparatus for measuring the gas permeability of a solid sample
Carstens, D.H.W.
1984-01-27
The disclosure is directed to an apparatus and method for measuring the permeability of a gas in a sample. The gas is allowed to reach a steady flow rate through the sample. A measurable amount of the gas is collected during a given time period and then delivered to a sensitive quadrupole. The quadrupole signal, adjusted for background, is proportional to the amount of gas collected during the time period. The quadrupole can be calibrated with a standard helium leak. The gas can be deuterium and the sample can be polyvinyl alcohol.
Xia, Yan; Li, Ming; Kučerka, Norbert; Li, Shutao; Nieh, Mu-Ping
2015-02-01
We have designed and constructed a temperature-controllable shear flow cell for in-situ study on flow alignable systems. The device has been tested in the neutron diffraction and has the potential to be applied in the small angle neutron scattering configuration to characterize the nanostructures of the materials under flow. The required sample amount is as small as 1 ml. The shear rate on the sample is controlled by the flow rate produced by an external pump and can potentially vary from 0.11 to 3.8 × 10(5) s(-1). Both unidirectional and oscillational flows are achievable by the setting of the pump. The instrument is validated by using a lipid bicellar mixture, which yields non-alignable nanodisc-like bicelles at low T and shear-alignable membranes at high T. Using the shear cell, the bicellar membranes can be aligned at 31 °C under the flow with a shear rate of 11.11 s(-1). Multiple high-order Bragg peaks are observed and the full width at half maximum of the "rocking curve" around the Bragg's condition is found to be 3.5°-4.1°. It is noteworthy that a portion of the membranes remains aligned even after the flow stops. Detailed and comprehensive intensity correction for the rocking curve has been derived based on the finite rectangular sample geometry and the absorption of the neutrons as a function of sample angle [See supplementary material at http://dx.doi.org/10.1063/1.4908165 for the detailed derivation of the absorption correction]. The device offers a new capability to study the conformational or orientational anisotropy of the solvated macromolecules or aggregates induced by the hydrodynamic interaction in a flow field.
Effects of continuum breakdown on hypersonic aerothermodynamics for reacting flow
NASA Astrophysics Data System (ADS)
Holman, Timothy D.; Boyd, Iain D.
2011-02-01
This study investigates the effects of continuum breakdown on the surface aerothermodynamic properties (pressure, stress, and heat transfer rate) of a sphere in a Mach 25 flow of reacting air in regimes varying from continuum to a rarefied gas. Results are generated using both continuum [computational fluid dynamics (CFD)] and particle [direct simulation Monte Carlo (DSMC)] approaches. The DSMC method utilizes a chemistry model that calculates the backward rates from an equilibrium constant. A preferential dissociation model is modified in the CFD method to better compare with the vibrationally favored dissociation model that is utilized in the DSMC method. Tests of these models are performed to confirm their validity and to compare the chemistry models in both numerical methods. This study examines the effect of reacting air flow on continuum breakdown and the surface properties of the sphere. As the global Knudsen number increases, the amount of continuum breakdown in the flow and on the surface increases. This increase in continuum breakdown significantly affects the surface properties, causing an increase in the differences between CFD and DSMC. Explanations are provided for the trends observed.
Development of Long-Lifetime Pulsed Gas Valves for Pulsed Electric Thrusters
NASA Technical Reports Server (NTRS)
Burkhardt, Wendel M.; Crapuchettes, John M.; Addona, Brad M.; Polzin, Kurt A.
2015-01-01
The design and test results for two types of pulsed gas valves are presented. The valves, a piezo valve and a solenoid actuated valve, must have exceedingly long lifetime to support gas-fed pulsed electric thruster operation for missions of interest. The performance of both valves was tested, with both demonstrating the capability to throttle the gas flow rate while maintaining low leakage levels below 10(exp -3) sccs of He at the beginning of valve lifetime. The piezo valve varies the flow rate by changing the amount that the valve is open, which is a function of applied voltage. This valve demonstrated continuous throttlability from 0-10 mL/s, with opening and closing times of 100 microsecond or less. The solenoid actuated valve flow rate changes as a function of the inlet gas pressure, with demonstrated flow rates in these tests from 2.7-11 mL per second. The valve response time is slower than the piezo valve, opening in 1-2 ms and closing in several ms. The solenoid actuated valve was tested to one million cycles, with the valve performance remaining relatively unchanged throughout the test. Galling of the sliding plunger caused the valve to bind and fail just after one million cycles, but at this point in the test the valve sealing surface leak rate still appeared to be well below the maximum target leak rake of 1×10(exp -3) sccs of He.
NASA Technical Reports Server (NTRS)
Schumann, H. H. (Principal Investigator)
1973-01-01
The author has identified the following significant results. The DCS water-stage data from the USGS streamflow gaging station on the Verde River near Camp Verde furnished information sufficient for the accurate computation of daily mean streamflow rates during the first 2 months of operation. Daily mean flow rates computed from the DCS data agreed with those computed from the digital recorder data within + or - 5% during periods of stable or slowly changing flow and within + or - 10% during periods of rapidly changing high flow. The SRP was furnished near-real time DCS information on snow moisture content and streamflow rates for use in the management and operation of the multiple-use reservoir system. The SRP, by prudent water management and the use of near-real time hydrologic data furnished by microwave and ERTS DCS telemetry, was successful in anticipating the amount of flow into the Salt and Verde Rivers and in the subsequent release of water at rates that did not create flooding in metropolitan Phoenix. Only minor flooding occurred along the Gila River west of Phoenix. According to the Maricopa County Civil Defense agency, wage and salary losses of about $11,400,000 resulted from closing of roads across the Salt River in the winter and spring of 1972-73; however, the number and duration of the closing were minimized by use of DCS data.
Sources of debris flow material in burned areas
Santi, P.M.; deWolfe, V.G.; Higgins, J.D.; Cannon, S.H.; Gartner, J.E.
2008-01-01
The vulnerability of recently burned areas to debris flows has been well established. Likewise, it has been shown that many, if not most, post-fire debris flows are initiated by runoff and erosion and grow in size through erosion and scour by the moving debris flow, as opposed to landslide-initiated flows with little growth. To better understand the development and character of these flows, a study has been completed encompassing 46 debris flows in California, Utah, and Colorado, in nine different recently burned areas. For each debris flow, progressive debris production was measured at intervals along the length of the channel, and from these measurements graphs were developed showing cumulative volume of debris as a function of channel length. All 46 debris flows showed significant bulking by scour and erosion, with average yield rates for each channel ranging from 0.3 to 9.9??m3 of debris produced for every meter of channel length, with an overall average value of 2.5??m3/m. Significant increases in yield rate partway down the channel were identified in 87% of the channels, with an average of a three-fold increase in yield rate. Yield rates for short reaches of channels (up to several hundred meters) ranged as high as 22.3??m3/m. Debris was contributed from side channels into the main channels for 54% of the flows, with an average of 23% of the total debris coming from those side channels. Rill erosion was identified for 30% of the flows, with rills contributing between 0.1 and 10.5% of the total debris, with an average of 3%. Debris was deposited as levees in 87% of the flows, with most of the deposition occurring in the lower part of the basin. A median value of 10% of the total debris flow was deposited as levees for these cases, with a range from near zero to nearly 100%. These results show that channel erosion and scour are the dominant sources of debris in burned areas, with yield rates increasing significantly partway down the channel. Side channels are much more important sources of debris than rills. Levees are very common, but the size and effect on the amount of debris that reaches a canyon mouth is highly variable. ?? 2007 Elsevier B.V. All rights reserved.
Investigation of hollow cathode performance for 30-cm thrusters
NASA Technical Reports Server (NTRS)
Mirtich, M. J.
1973-01-01
A parametric investigation of 6.35 mm diameter mercury hollow cathodes was carried out in a bell jar. The parameters that were varied were the amount of initial emissive mix, the insert position, the emission current, the cathode temperature, the orifice diameter, and the mercury flow rate. Flow characteristic curves and performance as a function of time were obtained for the various cathodes of interest. Also presented are the results of a 3880 hr life test of a main cathode run at 15 amps emission current with no noticeable changes in keeper and collector voltages.
Mafic-crystal distributions, viscosities, and lava structures of some Hawaiian lava flows
NASA Astrophysics Data System (ADS)
Rowland, Scott K.; Walker, George P. L.
1988-09-01
The distribution patterns of mafic phenocrysts in some Hawaiian basalt flows are consistent with simple in situ gravitational settling. We use the patterns to estimate the crystal settling velocity and hence viscosity of the lava, which in turn can be correlated with surface structures. Numerical modeling generates theoretical crystal concentration profiles through lava flow units of different thicknesses for differing settling velocities. By fitting these curves to field data, crystal-settling rates through the lavas can be estimated, from which the viscosities of the flows can be determined using Stokes' Law. Lavas in which the crystal settling velocity was relatively high (on the order of 5 × 10 -4 cm/sec) show great variations in phenocryst content, both from top to bottom of the same flow unit, and from one flow unit to another. Such lava is invariably pahoehoe, flow units of which are usually less than 1 m thick. Lavas in which the crystal-settling velocity was low show a small but measurable variation in phenocryst content. These lavas are part of a progression from a rough pahoehoe to toothpaste lava to a'a. Toothpaste lava is characterized by spiny texture as well as the ability to retain surface grooves during solidification, and flow units are usually thicker than 1 m. In the thickest of Hawaiian a'a flows, those of the distal type, no systematic crystal variations are observed, and high viscosity coupled with a finite yield strength prevented crystal settling. The amount of crystal settling in pahoehoe indicates that the viscosity ranged from 600 to 6000 Pa s. The limited amount of settling in toothpaste lava indicates a viscosity greater than this value, approaching 12,000 Pa s. We infer that distal-type a'a had a higher viscosity still and also possessed a yield strength.
NASA Astrophysics Data System (ADS)
Datta, T. S.; Kar, S.; Kumar, M.; Choudhury, A.; Chacko, J.; Antony, J.; Babu, S.; Sahu, S. K.
2015-12-01
Five beam line cryomodules with total 27 superconducting Radio Frequency (RF) cavities are installed and commissioned at IUAC to enhance the energy of heavy ion from 15 UD Pelletron. To reduce the heat load at 4.2 K, liquid nitrogen (LN2) cooled intermediate thermal shield is used for all these cryomodules. For three linac cryomodules, concept of forced flow LN2 cooling is used and for superbuncher and rebuncher, thermo-siphon cooling is incorporated. It is noticed that the shield temperature of superbuncher varies from 90 K to 110 K with respect to liquid nitrogen level. The temperature difference can't be explained by using the basic concept of thermo-siphon with the heat load on up flow line. A simple thermo-siphon experimental set up is developed to simulate the thermal shield temperature profile. Mass flow rate of liquid nitrogen is measured with different heat load on up flow line for different liquid levels. It is noticed that small amount of heat load on down flow line have a significant effect on mass flow rate. The present paper will be investigating the data generated from the thermosiphon experimental set up and a theoretical analysis will be presented here to validate the measured temperature profile of the cryomodule shield.
Investigation of radiative interactions in supersonic internal flows
NASA Technical Reports Server (NTRS)
Tiwari, Surendra N.; Thomas, A. M.
1991-01-01
Analyses and numerical procedures are presented to study the radiative interactions of absorbing emitting species in chemically reacting supersonic flow in various ducts. The 2-D time dependent Navier-Stokes equations in conjunction with radiative flux equation are used to study supersonic flows undergoing finite rate chemical reaction in a hydrogen air system. The specific problem considered is the flow of premixed radiating gas between parallel plates. Specific attention was directed toward studying the radiative contribution of H2O, OH, and NO under realistic physical and flow conditions. Results are presented for the radiative flux obtained for different gases and for various combination of these gases. The problem of chemically reacting and radiating flows was solved for the flow of premixed hydrogen-air through a 10 deg compression ramp. Results demonstrate that the radiative interaction increases with an increase in pressure, temperature, amount of participating species, plate spacing, and Mach number. Most of the energy, however, is transferred by convection in the flow direction. In general the results indicate that radiation can have a significant effect on the entire flow field.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Szkutnik, P. D., E-mail: pierre.szkutnik@cea.fr; Jiménez, C.; Angélidès, L.
2016-02-15
A solid delivery system consisting of a source canister, a gas management, and temperature controlled enclosure designed and manufactured by Air Liquide Electronics Systems was tested in the context of gas-phase delivery of the In(tmhd){sub 3} solid precursor. The precursor stream was delivered to a thermal metalorganic chemical vapor deposition reactor to quantify deposition yield under various conditions of carrier gas flow and sublimation temperature. The data collected allowed the determination of characteristic parameters such as the maximum precursor flow rate (18.2 mg min{sup −1} in specified conditions) and the critical mass (defined as the minimum amount of precursor ablemore » to attain the maximum flow rate) found to be about 2.4 g, as well as an understanding of the influence of powder distribution inside the canister. Furthermore, this qualification enabled the determination of optimal delivery conditions which allowed for stable and reproducible precursor flow rates over long deposition times (equivalent to more than 47 h of experiment). The resulting In{sub 2}O{sub 3} layers was compared with those elaborated via pulsed liquid injection obtained in the same chemical vapor deposition chamber and under the same deposition conditions.« less
Heeswijk, Marijke van; Smith, Daniel T.
2002-01-01
An evaluation of the interaction between ground-water flow on Naval Submarine Base Bangor and the regional-flow system shows that for selected alternatives of future ground-water pumping on and near the base, the risk is low that significant concentrations of on-base ground-water contamination will reach off-base public-supply wells and hypothetical wells southwest of the base. The risk is low even if worst-case conditions are considered ? no containment and remediation of on-base contamination. The evaluation also shows that future saltwater encroachment of aquifers below sea level may be possible, but this determination has considerable uncertainty associated with it. The potential effects on the ground-water flow system resulting from four hypothetical ground-water pumping alternatives were considered, including no change in 1995 pumping rates, doubling the rates, and 2020 rates estimated from population projections with two different pumping distributions. All but a continuation of 1995 pumping rates demonstrate the possibility of future saltwater encroachment in the Sea-level aquifer on Naval Submarine Base Bangor. The amount of time it would take for encroachment to occur is unknown. For all pumping alternatives, future saltwater encroachment in the Sea-level aquifer also may be possible along Puget Sound east and southeast of the base. Future saltwater encroachment in the Deep aquifer also may be possible throughout large parts of the study area. Projections of saltwater encroachment are least certain outside the boundaries of Naval Submarine Base Bangor. The potential effects of the ground-water pumping alternatives were evaluated by simulating the ground-water flow system with a three-dimensional uniform-density ground-water flow model. The model was calibrated by trial-and-error by minimizing differences between simulated and measured or estimated variables. These included water levels from prior to January 17, 1977 (termed 'predevelopment'), water-level drawdowns since predevelopment until April 15, 1995, ground-water discharge to streams in water year 1995, and residence times of ground water in different parts of the flow system that were estimated in a separate but related study. Large amounts of ground water were pumped from 1977 through 1980 from the Sea-level aquifer on Naval Submarine Base Bangor to enable the construction of an off-shore drydock. Records of the flow-system responses to the applied stresses were used to help calibrate the model. Errors in the calibrated model were significant. The poor agreement between simulated and measured values could be improved by making many local changes to hydraulic parameters but these changes were not supported by other data. Model errors may have resulted in errors in the simulated effects of ground-water pumping alternatives.
Kopsch, Thomas; Murnane, Darragh; Symons, Digby
2017-08-30
In dry powder inhalers (DPIs) the patient's inhalation manoeuvre strongly influences the release of drug. Drug release from a DPI may also be influenced by the size of any air bypass incorporated in the device. If the amount of bypass is high less air flows through the entrainment geometry and the release rate is lower. In this study we propose to reduce the intra- and inter-patient variations of drug release by controlling the amount of air bypass in a DPI. A fast computational method is proposed that can predict how much bypass is needed for a specified drug delivery rate for a particular patient. This method uses a meta-model which was constructed using multiphase computational fluid dynamic (CFD) simulations. The meta-model is applied in an optimization framework to predict the required amount of bypass needed for drug delivery that is similar to a desired target release behaviour. The meta-model was successfully validated by comparing its predictions to results from additional CFD simulations. The optimization framework has been applied to identify the optimal amount of bypass needed for fictitious sample inhalation manoeuvres in order to deliver a target powder release profile for two patients. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Faghri, Amir; Swanson, Theodore D.
1990-01-01
In the first section, improvements in the theoretical model and computational procedure for the prediction of film height and heat-transfer coefficient of the free surface flow of a radially-spreading thin liquid film adjacent to a flat horizontal surface of finite extent are presented. Flows in the presence and absence of gravity are considered. Theoretical results are compared to available experimental data with good agreement. In the presence of gravity, a hydraulic jump is present, isolating the flow into two regimes: supercritical upstream from the jump and subcritical downstream of it. In this situation, the effects of surface tension are important near the outer edge of the disk where the fluid experiences a free fall. A region of flow separation is present just downstream of the jump. In the absence of gravity, no hydraulic jump or separated flow region is present. The variation of the heat-transfer coefficient for flows in the presence and absence of gravity are also presented. In the second section, the results of a numerical simulation of the flow field and associated heat transfer coefficients are presented for the free surface flow of a thin liquid film adjacent to a horizontal rotating disk. The computation was performed for different flow rates and rotational velocities using a 3-D boundary-fitted coordinate system. Since the geometry of the free surface is unknown and dependent on flow rate, rate of rotation, and other parameters, an iterative procedure had to be used to ascertain its location. The computed film height agreed well with existing experimental measurements. The flow is found to be dominated by inertia near the entrance and close to the free surface and dominated by centrifugal force at larger radii and adjacent to the disk. The rotation enhances the heat transfer coefficient by a significant amount.
Schubert, Christopher E.
1999-01-01
The Peconic Estuary, at the eastern end of Long Island, has been plagued by a recurrent algal bloom that has caused the severe decline of local marine resources. Although the onset, duration, and cessation of the bloom remain unpredictable, ground-water discharge has been shown to affect surface-water quality in the western part of the estuary. Results from a study on the North Fork of Long Island indicate that local hydrogeologic factors cause differences in ground-water age and characteristics of discharge to the estuary. The need for information on the local patterns and rates of ground-water discharge to the Peconic Estuary prompted analysis of ground-water flow paths and traveltime to three small embayments within the estuary.Meetinghouse Creek, near the west end of the North Fork; Sag Harbor Cove, in the central part of the South Fork; and West Neck Bay, on Shelter Island.Ground-water-flow models were developed, and particle-tracking procedures were applied to the results of each model, to define the flow paths and traveltime of ground water to the three embayments. The steady-state flow models represent the two-dimensional ground-water-flow system along a vertical section through the uplands of each embayment and simulate long-term hydrologic conditions. The particle-tracking procedure used model-generated ground-water levels and flow rates to calculate the water-particle pathlines and times-of-travel through each flow system from the point of entry (recharge) to the point of exit at streams, the shore, or subsea-discharge areas.Results for the Meetinghouse Creek study area indicate that about 50 percent of the total recharge that enters the system flows southward to Meetinghouse Creek; half of this amount discharges as base flow to the fresh-water reach of the creek, and half as shoreline underflow to the estuarine reach. About 85 percent of the total discharge to Meetinghouse Creek has flowed entirely within the upper glacial aquifer, and about 15 percent has flowed through the Magothy aquifer. The average age of all ground water discharged to Meetinghouse Creek is about 60 years; the average age of base flow to the freshwater reach of the creek is about 7 years, and the average age of shoreline underflow to the estuarine reach is about 120 years. The results for the Sag Harbor Cove study area indicate that about 30 percent of the total recharge that enters the system flows northward to Sag Harbor Cove; about half of this amount discharges as shoreline underflow, and half as subsea underflow. About 40 percent of the total discharge to Sag Harbor Cove has flowed entirely within the upper glacial aquifer, and about 60 percent has flowed through the Pleistocene marine clay unit, Pleistocene(?) sand unit, or Magothy aquifer. The average age of all ground water discharged to Sag Harbor Cove is about 110 years; the average age of shoreline underflow is about 25 years, and the average age of subsea underflow is about 190 years.Results for the West Neck Bay study area indicate that about 65 percent of the total recharge that enters the system flows westward to West Neck Bay; virtually all of this amount discharges as shoreline underflow, but a negligible percentage discharges as subsea underflow. Virtually all discharge to West Neck Bay has flowed entirely within the upper glacial aquifer, although a minor amount has flowed through the Pleistocene marine clay unit. The average age of shoreline underflow to West Neck Bay is about 15 years, and the average age of subsea underflow is about 1,800 years.Ground water that discharges to streams and the shores represented in the models is mostly relatively young water that has flowed entirely within the shallow zones of the flow systems, whereas ground water that discharges to the subsea-discharge areas is mostly old water that has flowed through the deep zones. Data obtained from these models allows evaluation of each embayment.s vulnerability to contaminants introduced at the water table and can guide the development of source-area-protection strategies for the corresponding watersheds.
Quasi 1-D Analysis of a Circular, Compressible, Turbulent Jet Laden with Water Droplets. Appendix C
NASA Technical Reports Server (NTRS)
2001-01-01
Recent experimental studies indicate that presence of small amount of liquid droplets reduces the Overall Sound Pressure Level (OASPL) of a jet. Present study is aimed at numerically investigating the effect of liquid particles on the overall flow quantities of a heated, compressible round jet. The jet is assumed perfectly expanded. A quasi-1D model was developed for this purpose which uses area-averaged quantities that satisfy integral conservation equations. Special attention is given to represent the early development region since it is acoustically important. Approximate velocity and temperature profiles were assumed in this region to evaluate entrainment rate. Experimental correlations were used to obtain spreading rate of shear layer. The base flow thus obtained is then laden with water droplets at the exit of the nozzle. Mass, momentum and energy coupling between the two phases is represented using empirical relations. Droplet size and mass loading are varied to observe their effect on flow variables.
Information Flow in Teachers' Organizations in Israel During Confrontations with Employers: I
ERIC Educational Resources Information Center
Glasman, Naftaly S.
1975-01-01
First part of an article examining the content of information flow; the amount of information released; the mechanism of the flow; the factors affecting the content, amount, and mechanism; and the corollaries of information flow and the characteristics of the school system. Includes the questions put to the teachers. (Author/IRT)
Fux, C; Huang, D; Monti, A; Siegrist, H
2004-01-01
Nitrogen can be eliminated effectively from sludge digester effluents by anaerobic ammonium oxidation (anammox), but 55-60% of the ammonium must first be oxidized to nitrite. Although a continuous flow stirred tank reactor (CSTR) with suspended biomass could be used, its hydraulic dilution rate is limited to 0.8-1 d(-1) (30 degrees C). Higher specific nitrite production rates can be achieved by sludge retention, as shown here for a moving-bed biofilm reactor (MBBR) with Kaldnes carriers on laboratory and pilot scales. The maximum nitrite production rate amounted to 2.7 gNO2-Nm(-2)d(-1) (3 gO2m(-3)d(-1), 30.5 degrees C), thus doubling the dilution rate compared to CSTR operation with suspended biomass for a supernatant with 700 gNH4-Nm(-3). Whenever the available alkalinity was fully consumed, an optimal amount of nitrite was produced. However, a significant amount of nitrate was produced after 11 months of operation, making the effluent unsuitable for anaerobic ammonium oxidation. Because the sludge retention time (SRT) is relatively long in biofilm systems, slow growth of nitrite oxidizers occurs. None of the selection criteria applied - a high ammonium loading rate, high free ammonia or low oxygen concentration - led to selective suppression of nitrite oxidation. A CSTR or SBR with suspended biomass is consequently recommended for full-scale operation.
Newton, Teresa J.; Zigler, Steven J.; Rogala, James T.; Gray, Brian R.; Davis, Mike
2011-01-01
1. Despite a heightened global concern for native mussels, fundamental research on mussel ecology in large rivers is lacking. These gaps in knowledge about where mussels occur, and why, are limiting habitat restoration activities. 2. Large-scale systematic surveys for native mussels in three reaches of the Upper Mississippi River documented mussel communities composed of 16–23 species and ranging from 2.9–4.5 live mussels m-2 that were actively recruiting new cohorts into their populations (87–100% of the species were found as juveniles 5 years old). Estimates of mean tissue biomass and production in these reaches ranged from 2.1–3.1 g C m-2 and 0.4–0.6 g C m-2year-1, respectively. 3. Mussels filtered a significant amount of water (range, 0.05–0.07 m3m-2d-1) over a 480 km reach of the Upper Mississippi River — amounting to a filtration rate of 53.1 million m3day-1. The filtration rate of mussels as a percentage of river discharge ranged from 0.5–1.4% at high flows (5% exceedance), from 1.5–4.4% at moderate flows (50% exceedance) and from 4.4–12.2% during low flows (95% exceedance). 4. Collectively, these data suggest that native mussels play an integral role in this ecosystem by sequestering suspended materials that can be used by other benthic organisms.
Prudic, David E.
1989-01-01
Computer models are widely used to simulate groundwater flow for evaluating and managing the groundwater resource of many aquifers, but few are designed to also account for surface flow in streams. A computer program was written for use in the US Geological Survey modular finite difference groundwater flow model to account for the amount of flow in streams and to simulate the interaction between surface streams and groundwater. The new program is called the Streamflow-Routing Package. The Streamflow-Routing Package is not a true surface water flow model, but rather is an accounting program that tracks the flow in one or more streams which interact with groundwater. The program limits the amount of groundwater recharge to the available streamflow. It permits two or more streams to merge into one with flow in the merged stream equal to the sum of the tributary flows. The program also permits diversions from streams. The groundwater flow model with the Streamflow-Routing Package has an advantage over the analytical solution in simulating the interaction between aquifer and stream because it can be used to simulate complex systems that cannot be readily solved analytically. The Streamflow-Routing Package does not include a time function for streamflow but rather streamflow entering the modeled area is assumed to be instantly available to downstream reaches during each time period. This assumption is generally reasonable because of the relatively slow rate of groundwater flow. Another assumption is that leakage between streams and aquifers is instantaneous. This assumption may not be reasonable if the streams and aquifers are separated by a thick unsaturated zone. Documentation of the Streamflow-Routing Package includes data input instructions; flow charts, narratives, and listings of the computer program for each of four modules; and input data sets and printed results for two test problems, and one example problem. (Lantz-PTT)
NASA Astrophysics Data System (ADS)
Howell, Robert R.; Radebaugh, Jani; M. C Lopes, Rosaly; Kerber, Laura; Solomonidou, Anezina; Watkins, Bryn
2017-10-01
Using remote sensing of planetary volcanism on objects such as Io to determine eruption conditions is challenging because the emitting region is typically not resolved and because exposed lava cools so quickly. A model of the cooling rate and eruption mechanism is typically used to predict the amount of surface area at different temperatures, then that areal distribution is convolved with a Planck blackbody emission curve, and the predicted spectra is compared with observation. Often the broad nature of the Planck curve makes interpretation non-unique. However different eruption mechanisms (for example cooling fire fountain droplets vs. cooling flows) have very different area vs. temperature distributions which can often be characterized by simple power laws. Furthermore different composition magmas have significantly different upper limit cutoff temperatures. In order to test these models in August 2016 and May 2017 we obtained spatially resolved observations of spreading Kilauea pahoehoe flows and fire fountains using a three-wavelength near-infrared prototype camera system. We have measured the area vs. temperature distribution for the flows and find that over a relatively broad temperature range the distribution does follow a power law matching the theoretical predictions. As one approaches the solidus temperature the observed area drops below the simple model predictions by an amount that seems to vary inversely with the vigor of the spreading rate. At these highest temperatures the simple models are probably inadequate. It appears necessary to model the visco-elastic stretching of the very thin crust which covers even the most recently formed surfaces. That deviation between observations and the simple models may be particularly important when using such remote sensing observations to determine magma eruption temperatures.
Extracorporeal CO2 removal by hemodialysis: in vitro model and feasibility.
May, Alexandra G; Sen, Ayan; Cove, Matthew E; Kellum, John A; Federspiel, William J
2017-12-01
Critically ill patients with acute respiratory distress syndrome and acute exacerbations of chronic obstructive pulmonary disease often develop hypercapnia and require mechanical ventilation. Extracorporeal carbon dioxide removal can manage hypercarbia by removing carbon dioxide directly from the bloodstream. Respiratory hemodialysis uses traditional hemodialysis to remove CO 2 from the blood, mainly as bicarbonate. In this study, Stewart's approach to acid-base chemistry was used to create a dialysate that would maintain blood pH while removing CO 2 as well as determine the blood and dialysate flow rates necessary to remove clinically relevant CO 2 volumes. Bench studies were performed using a scaled down respiratory hemodialyzer in bovine or porcine blood. The scaling factor for the bench top experiments was 22.5. In vitro dialysate flow rates ranged from 2.2 to 24 mL/min (49.5-540 mL/min scaled up) and blood flow rates were set at 11 and 18.7 mL/min (248-421 mL/min scaled up). Blood inlet CO 2 concentrations were set at 50 and 100 mmHg. Results are reported as scaled up values. The CO 2 removal rate was highest at intermittent hemodialysis blood and dialysate flow rates. At an inlet pCO 2 of 50 mmHg, the CO 2 removal rate increased from 62.6 ± 4.8 to 77.7 ± 3 mL/min when the blood flow rate increased from 248 to 421 mL/min. At an inlet pCO 2 of 100 mmHg, the device was able to remove up to 117.8 ± 3.8 mL/min of CO 2 . None of the test conditions caused the blood pH to decrease, and increases were ≤0.08. When the bench top data is scaled up, the system removes a therapeutic amount of CO 2 standard intermittent hemodialysis flow rates. The zero bicarbonate dialysate did not cause acidosis in the post-dialyzer blood. These results demonstrate that, with further development, respiratory hemodialysis can be a minimally invasive extracorporeal carbon dioxide removal treatment option.
Electrokinetic remediation prefield test methods
NASA Technical Reports Server (NTRS)
Hodko, Dalibor (Inventor)
2000-01-01
Methods for determining the parameters critical in designing an electrokinetic soil remediation process including electrode well spacing, operating current/voltage, electroosmotic flow rate, electrode well wall design, and amount of buffering or neutralizing solution needed in the electrode wells at operating conditions are disclosed These methods are preferably performed prior to initiating a full scale electrokinetic remediation process in order to obtain efficient remediation of the contaminants.
Linares, Oscar A; Schiesser, William E; Fudin, Jeffrey; Pham, Thien C; Bettinger, Jeffrey J; Mathew, Roy O; Daly, Annemarie L
2015-01-01
Background There is a need to have a model to study methadone’s losses during hemodialysis to provide informed methadone dose recommendations for the practitioner. Aim To build a one-dimensional (1-D), hollow-fiber geometry, ordinary differential equation (ODE) and partial differential equation (PDE) countercurrent hemodialyzer model (ODE/PDE model). Methodology We conducted a cross-sectional study in silico that evaluated eleven hemodialysis patients. Patients received a ceiling dose of methadone hydrochloride 30 mg/day. Outcome measures included: the total amount of methadone removed during dialysis; methadone’s overall intradialytic mass transfer rate coefficient, km; and, methadone’s removal rate, jME. Each metric was measured at dialysate flow rates of 250 mL/min and 800 mL/min. Results The ODE/PDE model revealed a significant increase in the change of methadone’s mass transfer with increased dialysate flow rate, %Δkm=18.56, P=0.02, N=11. The total amount of methadone mass transferred across the dialyzer membrane with high dialysate flow rate significantly increased (0.042±0.016 versus 0.052±0.019 mg/kg, P=0.02, N=11). This was accompanied by a small significant increase in methadone’s mass transfer rate (0.113±0.002 versus 0.014±0.002 mg/kg/h, P=0.02, N=11). The ODE/PDE model accurately predicted methadone’s removal during dialysis. The absolute value of the prediction errors for methadone’s extraction and throughput were less than 2%. Conclusion ODE/PDE modeling of methadone’s hemodialysis is a new approach to study methadone’s removal, in particular, and opioid removal, in general, in patients with end-stage renal disease on hemodialysis. ODE/PDE modeling accurately quantified the fundamental phenomena of methadone’s mass transfer during hemodialysis. This methodology may lead to development of optimally designed intradialytic opioid treatment protocols, and allow dynamic monitoring of outflow plasma opioid concentrations for model predictive control during dialysis in humans. PMID:26229501
Wan, Jiamin; Tokunaga, Tetsu K; Kim, Yongman; Wang, Zheming; Lanzirotti, Antonio; Saiz, Eduardo; Serne, R Jeffrey
2008-03-15
The accidental overfilling of waste liquid from tank BX-102 at the Hanford Site in 1951 put about 10 t of U(VI) into the vadose zone. In order to understand the dominant geochemical reactions and transport processes that occurred during the initial infiltration and to help understand current spatial distribution, we simulated the waste liquid spilling event in laboratory sediment columns using synthesized metal waste solution. We found that, as the plume propagated through sediments, pH decreased greatly (as much as 4 units) at the moving plume front. Infiltration flow rates strongly affect U behavior. Slower flow rates resulted in higher sediment-associated U concentrations, and higher flow rates (> or =5 cm/day) permitted practically unretarded U transport. Therefore, given the very high Ksat of most of Hanford formation, the low permeability zones within the sediment could have been most important in retaining high concentrations of U during initial release into the vadose zone. Massive amount of colloids, including U-colloids, formed at the plume fronts. Total U concentrations (aqueous and colloid) within plume fronts exceeded the source concentration by up to 5-fold. Uranium colloid formation and accumulation at the neutralized plume front could be one mechanism responsible for highly heterogeneous U distribution observed in the contaminated Hanford vadose zone.
Co-combustion of pellets from Soma lignite and waste dusts of furniture works
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deveci, N.D.; Yilgin, M.; Pehlivan, D.
2008-07-01
In this work, volatiles and char combustion behaviors of the fuel pellets prepared from a low quality lignite and the dusts of furniture works and their various blends were investigated in an experimental fixed bed combustion system through which air flowed by natural convection. Combustion data obtained for varied bed temperatures, mass of pellets, and blend compositions has showed that ignition times of the pellets decreased and volatiles combustion rates tended to increase with the burning temperature. It was concluded that some synergy had existed between lignite and lower ratios of furniture work dusts, which was indicated by a promptmore » effect on the volatiles combustion rates. Char combustion rates of blend pellets have depended predominantly on the amount of lignite in the blend. The amounts of combustion residues of the pellets were considerably higher than those calculated from individual ash contents of the raw materials and related to lignite ratio in the blends.« less
NASA Technical Reports Server (NTRS)
Romanishin, W.
1988-01-01
Preliminary results are given for a program to measure color gradients in the central galaxies in clusters with a variety of cooling flow rates. The objectives are to search for extended blue continuum regions indicative of star formation, to study the spatial distribution of star formation, and to make a quantitative measure of the amount of light from young stars, which can lead to a measure of the star formation rate (for an assumed initial mass function). Four clusters with large masses and large cluster H-alpha emission fluxes are found to have an excess of blue light concentrated to the centers of the cluster central galaxy. Assumption of a disk IMF leads to the conclusion that the starlight might play a major role in ionizing the emission line gas in these clusters.
Pessarrodona, Albert; Moore, Pippa J; Sayer, Martin D J; Smale, Dan A
2018-06-03
Global climate change is affecting carbon cycling by driving changes in primary productivity and rates of carbon fixation, release and storage within Earth's vegetated systems. There is, however, limited understanding of how carbon flow between donor and recipient habitats will respond to climatic changes. Macroalgal-dominated habitats, such as kelp forests, are gaining recognition as important carbon donors within coastal carbon cycles, yet rates of carbon assimilation and transfer through these habitats are poorly resolved. Here, we investigated the likely impacts of ocean warming on coastal carbon cycling by quantifying rates of carbon assimilation and transfer in Laminaria hyperborea kelp forests-one of the most extensive coastal vegetated habitat types in the NE Atlantic-along a latitudinal temperature gradient. Kelp forests within warm climatic regimes assimilated, on average, more than three times less carbon and donated less than half the amount of particulate carbon compared to those from cold regimes. These patterns were not related to variability in other environmental parameters. Across their wider geographical distribution, plants exhibited reduced sizes toward their warm-water equatorward range edge, further suggesting that carbon flow is reduced under warmer climates. Overall, we estimated that Laminaria hyperborea forests stored ~11.49 Tg C in living biomass and released particulate carbon at a rate of ~5.71 Tg C year -1 . This estimated flow of carbon was markedly higher than reported values for most other marine and terrestrial vegetated habitat types in Europe. Together, our observations suggest that continued warming will diminish the amount of carbon that is assimilated and transported through temperate kelp forests in NE Atlantic, with potential consequences for the coastal carbon cycle. Our findings underline the need to consider climate-driven changes in the capacity of ecosystems to fix and donate carbon when assessing the impacts of climate change on carbon cycling. © 2018 The Authors Global Change Biology Published by John Wiley & Sons Ltd.
Failure mechanisms of fibrin-based surgical tissue adhesives
NASA Astrophysics Data System (ADS)
Sierra, David Hugh
A series of studies was performed to investigate the potential impact of heterogeneity in the matrix of multiple-component fibrin-based tissue adhesives upon their mechanical and biomechanical properties both in vivo and in vitro. Investigations into the failure mechanisms by stereological techniques demonstrated that heterogeneity could be measured quantitatively and that the variation in heterogeneity could be altered both by the means of component mixing and delivery and by the formulation of the sealant. Ex vivo tensile adhesive strength was found to be inversely proportional to the amount of heterogeneity. In contrast, in vivo tensile wound-closure strength was found to be relatively unaffected by the degree of heterogeneity, while in vivo parenchymal organ hemostasis in rabbits was found to be affected: greater heterogeneity appeared to correlate with an increase in hemostasis time and amount of sealant necessary to effect hemostasis. Tensile testing of the bulk sealant showed that mechanical parameters were proportional to fibrin concentration and that the physical characteristics of the failure supported a ductile mechanism. Strain hardening as a function of percentage of strain, and strain rate was observed for both concentrations, and syneresis was observed at low strain rates for the lower fibrin concentration. Blister testing demonstrated that burst pressure and failure energy were proportional to fibrin concentration and decreased with increasing flow rate. Higher fibrin concentration demonstrated predominately compact morphology debonds with cohesive failure loci, demonstrating shear or viscous failure in a viscoelastic rubbery adhesive. The lower fibrin concentration sealant exhibited predominately fractal morphology debonds with cohesive failure loci, supporting an elastoviscous material condition. The failure mechanism for these was hypothesized and shown to be flow-induced ductile fracture. Based on these findings, the failure mechanism was stochastic in nature because the mean failure energy and burst pressure values were not predictive of locus and morphology. Instead, flow rate and fibrin concentration showed the most predictive value, with the outcome best described as a probability distribution rather than a specific deterministic outcome.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Withers, C.; Cummings, J.; Nigusse, B.
A new generation of full variable-capacity, central, ducted air-conditioning (AC) and heat pump units has come on the market, and they promise to deliver increased cooling (and heating) efficiency. They are controlled differently than standard single-capacity (fixed-capacity) systems. Instead of cycling on at full capacity and then cycling off when the thermostat is satisfied, they can vary their capacity over a wide range (approximately 40% to 118% of nominal full capacity), thus staying “on” for up to twice as many hours per day compared to fixed-capacity systems of the same nominal capacity. The heating and cooling capacity is varied bymore » adjusting the indoor fan air flow rate, compressor, and refrigerant flow rate as well as the outdoor unit fan air flow rate. Note that two-stage AC or heat pump systems were not evaluated in this research effort. The term dwell is used to refer to the amount of time distributed air spends inside ductwork during space-conditioning cycles. Longer run times mean greater dwell time and therefore greater exposure to conductive gains and losses.« less
Sanford, W.E.; Plummer, Niel; McAda, D.P.; Bexfield, L.M.; Anderholm, S.K.
2004-01-01
The calibration of a groundwater model with the aid of hydrochemical data has demonstrated that low recharge rates in the Middle Rio Grande Basin may be responsible for a groundwater trough in the center of the basin and for a substantial amount of Rio Grande water in the regional flow system. Earlier models of the basin had difficulty reproducing these features without any hydrochemical data to constrain the rates and distribution of recharge. The objective of this study was to use the large quantity of available hydrochemical data to help calibrate the model parameters, including the recharge rates. The model was constructed using the US Geological Survey's software MODFLOW, MODPATH, and UCODE, and calibrated using 14C activities and the positions of certain flow zones defined by the hydrochemical data. Parameter estimation was performed using a combination of nonlinear regression techniques and a manual search for the minimum difference between field and simulated observations. The calibrated recharge values were substantially smaller than those used in previous models. Results from a 30,000-year transient simulation suggest that recharge was at a maximum about 20,000 years ago and at a minimum about 10,000 years ago. ?? Springer-Verlag 2004.
NASA Astrophysics Data System (ADS)
Derr, Igor; Bruns, Michael; Langner, Joachim; Fetyan, Abdulmonem; Melke, Julia; Roth, Christina
2016-09-01
Electrochemical degradation (ED) of carbon felt electrodes was investigated by cycling of a flow through all-vanadium redox flow battery (VRFB) and conducting half-cell measurements with two reference electrodes inside the test bench. ED was detected using half-cell and full-cell electrochemical impedance spectroscopy (EIS) at different states of charge (SOC). Reversing the polarity of the battery to recover cell performance was performed with little success. Renewing the electrolyte after a certain amount of cycles restored the capacity of the battery. X-ray photoelectron spectroscopy (XPS) reveals that the amount of surface functional increases by more than a factor of 3 for the negative side as well as for the positive side. Scanning electron microscope (SEM) images show a peeling of the fiber surface after cycling the felts, which leads to a loss of electrochemically active surface area (ECSA). Long term cycling shows that ED has a stronger impact on the negative half-cell [V(II)/V(III)] than the positive half-cell [V(IV)/V(V)] and that the negative half-cell is the rate-determining half-cell for the VRFB.
Polymer flexibility and turbulent drag reduction.
Gillissen, J J J
2008-10-01
Polymer-induced drag reduction is the phenomenon by which the friction factor of a turbulent flow is reduced by the addition of small amounts of high-molecular-weight linear polymers, which conformation in solution at rest can vary between randomly coiled and rodlike. It is well known that drag reduction is positively correlated to viscous stresses, which are generated by extended polymers. Rodlike polymers always assume this favorable conformation, while randomly coiling chains need to be unraveled by fluid strain rate in order to become effective. The coiling and stretching of flexible polymers in turbulent flow produce an additional elastic component in the polymer stress. The effect of the elastic stresses on drag reduction is unclear. To study this issue, we compare direct numerical simulations of turbulent drag reduction in channel flow using constitutive equations describing solutions of rigid and flexible polymers. When compared at constant phi r2, both simulations predict the same amount of drag reduction. Here phi is the polymer volume fraction and r is the polymer aspect ratio, which for flexible polymers is based on average polymer extension at the channel wall. This demonstrates that polymer elasticity plays a marginal role in the mechanism for drag reduction.
Oxygen delivery using neonatal self-inflating bags without reservoirs.
Sugiura, Takahiro; Urushibata, Rei; Komatsu, Kenji; Shioda, Tsutomu; Ota, Tatsuki; Sato, Megumi; Okubo, Yumiko; Fukuoka, Tetsuya; Hosono, Shigeharu; Tamura, Masanori
2017-02-01
Guidelines recommend avoiding excessive oxygen during neonatal resuscitation. Recent studies have suggested that oxygen titration can be achieved using a self-inflating bag, but data on the effectiveness of resuscitators used in neonatal ventilation are scarce, The aim of this study was therefore to determine the amount of oxygen delivered using several brands of neonatal self-inflating resuscitation bags without reservoirs under different conditions with regard to oxygen flow rate, ventilation rate (VR), peak inspiratory pressure (PIP) range, and test lung compliance. Oxygen concentration was measured under a variety of conditions. Combinations of oxygen flow rate (10, 5.0, 3.0 and 1.0 L/min), VR (40, 60 inflations/min), PIP range (20-25 cmH 2 O, 35-40 cmH 2 O), and test lung compliance (0.6, 1.0, 3.0, and 5.0 mL/cmH 2 O) were examined using six kinds of self-inflating bag. Delivered oxygen concentration varied widely (30.1-96.7%) and had a significant positive correlation with gas flow rate in all of the bags. Delivered oxygen concentration was also negatively correlated with PIP in all of the bags and with VR in some of them. Test lung compliance did not affect delivered oxygen concentration. The use of neonatal resuscitation self-inflating bags without reservoirs resulted in different delivered oxygen concentrations depending on gas flow rate, VR, PIP, and manufacturer, but not on lung compliance. This suggests that targeted oxygen concentrations could be delivered, even in lungs with decreased compliance, during resuscitation. © 2016 Japan Pediatric Society.
Impact of microbial activity on the hydraulic properties of fractured chalk.
Arnon, Shai; Adar, Eilon; Ronen, Zeev; Yakirevich, Alexander; Nativ, Ronit
2005-02-01
The impact of microbial activity on fractured chalk transmissivity was investigated on a laboratory scale. Long-term experiments were conducted on six fractured chalk cores (20 cm diameter, 23-44 cm long) containing a single natural fracture embedded in a porous matrix. Biodegradation experiments were conducted under various conditions, including several substrate and oxygen concentrations and flow rates. 2,4,6-Tribromophenol (TBP) was used as a model contaminant (substrate). TBP biodegradation efficiency depended mainly on the amount of oxygen. However, under constant oxygen concentration at the core inlet, elevating the flow rates increased the removal rate of TBP. Transmissivity reduction was clearly related to TBP removal rate, following an initial slow decline and a further sharp decrease with time. The fracture's transmissivity was reduced by as much as 97% relative to the initial value, with no leveling off of the clogging process. For the most extreme cases, reductions of 262 and 157 microm in the equivalent hydraulic apertures were recorded for fractures with initial apertures of 495 and 207 microm, respectively. The reductions in fracture transmissivity occurred primarily because of clogging by bacterial cells and extracellular polymeric substances (EPS) produced by the bacteria. Most of the biodegradation activity was concentrated near the fracture inlet, where the most suitable biodegradation conditions (nutrients and oxygen) prevailed, suggesting that the clogging had occurred in that vicinity. The clogging must have changed the structure of the fracture void, thereby reducing the active volume participating in flow and transport processes. This phenomenon caused accelerated transport of non-reactive tracers and doubled the fracture's dispersivity under constant flow rates.
Optimisation of the Sputnik-VAD design.
Selishchev, Sergey V; Telyshev, Dmitry V
2016-10-10
Miniaturisation of VADs can offer important benefits, including less invasive implantation techniques and more versatility in patient selection. The aim of this work was to reduce the weight, size, and energy consumption of the Sputnik VAD. The second generation of the Sputnik VAD was developed with a set of changes in construction. The head pressure-flow rate (H-Q) and power consumption-flow rate curves for the Sputnik VADs were measured at different rotational speeds. Computational fluid dynamics (CFD) were used for operating condition simulation and the LVADs were compared under the simulated physiological conditions. The slope of the H-Q curves for the Sputnik 1 VAD remains almost invariable over the entire range of the measured flow rate, in contrast to the curves for the Sputnik 2 VAD, which become flat in the high flow-rate region. Despite the design modification, the operating rotor speed remained invariable. The preload sensitivity of the Sputnik VAD is higher than that of the other rotary blood pumps and amounts to 0.111 ± 0.0092 L min-1 mmHg-1. The power consumption for the Sputnik 2 VAD is lower over the entire speed range, except for at 5,000 rpm. The pump weight was reduced from 246 to 205 g, the pump length was decreased from 82 to 66 mm, and the pump diameter was decreased from 32 to 29 mm. The total energy consumption of the pump was reduced by 15%.
Emplacement of Columbia River flood basalt
NASA Astrophysics Data System (ADS)
Reidel, Stephen P.
1998-11-01
Evidence is examined for the emplacement of the Umatilla, Wilbur Creek, and the Asotin Members of Columbia River Basalt Group. These flows erupted in the eastern part of the Columbia Plateau during the waning phases of volcanism. The Umatilla Member consists of two flows in the Lewiston basin area and southwestern Columbia Plateau. These flows mixed to form one flow in the central Columbia Plateau. The composition of the younger flow is preserved in the center and the composition of the older flow is at the top and bottom. There is a complete gradation between the two. Flows of the Wilbur Creek and Asotin Members erupted individually in the eastern Columbia Plateau and also mixed together in the central Columbia Plateau. Comparison of the emplacement patterns to intraflow structures and textures of the flows suggests that very little time elapsed between eruptions. In addition, the amount of crust that formed on the earlier flows prior to mixing also suggests rapid emplacement. Calculations of volumetric flow rates through constrictions in channels suggest emplacement times of weeks to months under fast laminar flow for all three members. A new model for the emplacement of Columbia River Basalt Group flows is proposed that suggests rapid eruption and emplacement for the main part of the flow and slower emplacement along the margins as the of the flow margin expands.
Surfactant-Induced Changes of Water Flow and Solute Transport in Soils
NASA Astrophysics Data System (ADS)
Kinsey, E. N.; Korte, C.; Peng, Z.; Yu, C.; Powelson, D.; Jacobson, A. R.; Baveye, P. C.; Darnault, C. J. G.
2016-12-01
Surfactants are present in the environment due to agricultural practices such as irrigation with wastewater, biosolid soil amendments, and/or environmental engineering remediation. Furthermore, surfactants occur widely in soils due to the application of pesticides in surfactant solution sprays, or the application of surfactants as soil wetting agents. Surfactants, because they are amphiphilic and impact the surface tension of aqueous solutions and the contact angle between aqueous and solid phases have the potential to influence water flow in porous media and the physicochemical properties of soils. The objective of this study was to assess the impact of surfactant on the soil infiltration process. Four different soils were used in this study: two sandy loam soils (Lewiston and Greenson series) and two loamy sand soils (Sparta and Gilford series). Rainfall was simulated to flow through different columns filled with the four different types of soil and effluent samples were collected at the end of each column. Each type of soil had two columns, one with a non-ionic surfactant Aerosol®22 at twice the critical micelle concentration, in the rainfall solution and one without. A conservative tracer, potassium bromide, was added to all rainfalls to monitor the infiltration process in soil. Tracer breakthrough curves were used to characterize flow in soils. Flow rates were also recorded for each soil. The presence of surfactant decreased the flow rate by a significant amount in most soil types. The decrease in flow rate can be attributed to the effects on the soil properties of hydraulic conductivity and soil aggregates. A decrease in pore space from the swelling of the soil particles can decrease the hydraulic conductivity. The properties in surfactants also decrease the surface tension and therefore soil particles are able to be dislodged from soil aggregates and cause potential soil clogging.
Gieseler, Henning; Kessler, William J; Finson, Michael; Davis, Steven J; Mulhall, Phillip A; Bons, Vincent; Debo, David J; Pikal, Michael J
2007-07-01
The goal of this work was to demonstrate the use of Tunable Diode Laser Absorption Spectroscopy (TDLAS) as a noninvasive method to continuously measure the water vapor concentration and the vapor flow velocity in the spool connecting a freeze-dryer chamber and condenser. The instantaneous measurements were used to determine the water vapor mass flow rate (g/s). The mass flow determinations provided a continuous measurement of the total amount of water removed. Full load runs of pure water at different pressure and shelf temperature settings and a 5% (w/w) mannitol product run were performed in both laboratory and pilot scale freeze dryers. The ratio of "gravimetric/TDLAS" measurements of water removed was 1.02 +/- 0.06. A theoretical heat transfer model was used to predict the mass flow rate and the model results were compared to both the gravimetric and TDLAS data. Good agreement was also observed in the "gravimetric/TDLAS" ratio for the 5% mannitol runs dried in both freeze dryers. The endpoints of primary and secondary drying for the product runs were clearly identified. Comparison of the velocity and mass flux profiles between the laboratory and pilot dryers indicated a higher restriction to mass flow for the lab scale freeze dryer. Copyright 2007 Wiley-Liss, Inc.
The Generation of Barriers to Melt Ascent in the Martian Lithosphere
NASA Astrophysics Data System (ADS)
Schools, Joe W.; Montési, Laurent G. J.
2018-01-01
Planetary mantles can be regarded as an aggregate of two phases: a solid, porous matrix and a liquid melt. Melt travels rapidly upward through the matrix due to its buoyancy. When this melt enters the colder lithosphere, it begins to crystallize. If crystallization happens at a high rate, the newly formed crystals can clog the pore space, reducing its permeability to essentially zero. This zone of zero permeability is the permeability barrier. We use the MELTS family of thermodynamic calculators to determine melt compositions and the crystallization sequence of ascending melt throughout Martian history and simulate the formation of permeability barriers. At lower strain rates (10-17-10-15 s-1) permeability barriers form deep in the lithosphere, possibly contributing to the formation of localized volcanic edifices on the Martian surface once fracturing or thermal erosion enables melt to traverse the lithosphere. Higher strain rates (10-13 s-1) yield shallower permeability barriers, perhaps producing extensive lava flows. Permeability barrier formation is investigated using an anhydrous mantle source or mantle sources that include up to 1,000 ppm H2O. Introducing even small amounts of water (25 ppm H2O) reduces mantle viscosity in a manner similar to increasing the strain rate and results in a shallower barrier than in the anhydrous case. Large amounts of water (1,000 ppm H2O) yield very shallow weak barriers or no barriers at all. The depth of the permeability barrier has evolved through time, likely resulting in a progression in the style of surface volcanism from widespread flows to massive, singular volcanoes.
Effects of gas flow on oxidation reaction in liquid induced by He/O{sub 2} plasma-jet irradiation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nakajima, Atsushi; Uchida, Giichiro, E-mail: uchida@jwri.osaka-u.ac.jp; Takenaka, Kosuke
We present here analysis of oxidation reaction in liquid by a plasma-jet irradiation under various gas flow patterns such as laminar and turbulence flows. To estimate the total amount of oxidation reaction induced by reactive oxygen species (ROS) in liquid, we employ a KI-starch solution system, where the absorbance of the KI-starch solution near 600 nm behaves linear to the total amount of oxidation reaction in liquid. The laminar flow with higher gas velocity induces an increase in the ROS distribution area on the liquid surface, which results in a large amount of oxidation reaction in liquid. However, a much fastermore » gas flow conversely results in a reduction in the total amount of oxidation reaction in liquid under the following two conditions: first condition is that the turbulence flow is triggered in a gas flow channel at a high Reynolds number of gas flow, which leads to a marked change of the spatial distribution of the ROS concentration in gas phase. Second condition is that the dimpled liquid surface is formed by strong gas flow, which prevents the ROS from being transported in radial direction along the liquid surface.« less
NASA Astrophysics Data System (ADS)
Wang, Guang; Liu, Yingli; Zhou, Zhenfeng; Wang, Jingsong; Xue, Qingguo
2018-01-01
The liquid-phase flow behavior of slag in the lower zone of a blast furnace affects the furnace permeability, performance, and productivity. The effects of pulverized coal injection (PCI) on the behavior of simulated primary slag flow were investigated by quantifying the effect of key variables including Al/Si ratio [Al2O3 (wt.%) to SiO2 (wt.%)] and the amount of unburnt pulverized coal (UPC) at 1500°C. Viscosity analysis demonstrated that the slag fluidity decreased as the Al/Si ratio was increased (from 0.35 to 0.50), resulting in gradual increase of the static holdup. Increasing the amount of UPC resulted in a significant increase of the static holdup. Flooding analysis was applied to determine the maximum static holdup, which was found to be 11.5%. It was inferred that the burnout rates of pulverized coal should exceed 78.6% and 83.9% in traditional and oxygen blast furnaces, respectively.
NASA Astrophysics Data System (ADS)
Endo, Noritaka
2016-12-01
A simple stochastic cellular automaton model is proposed for simulating bedload transport, especially for cases with a low transport rate and where available sediments are very sparse on substrates in a subaqueous system. Numerical simulations show that the bed type changes from sheet flow through sand patches to ripples as the amount of sand increases; this is consistent with observations in flume experiments and in the field. Without changes in external conditions, the sand flux calculated for a given amount of sand decreases over time as bedforms develop from a flat bed. This appears to be inconsistent with the general understanding that sand flux remains unchanged under the constant-fluid condition, but it is consistent with the previous experimental data. For areas of low sand abundance, the sand flux versus sand amount (flux-density relation) in the simulation shows a single peak with an abrupt decrease, followed by a long tail; this is very similar to the flux-density relation seen in automobile traffic flow. This pattern (the relation between segments of the curve and the corresponding bed states) suggests that sand sheets, sand patches, and sand ripples correspond respectively to the free-flow phase, congested phase, and jam phase of traffic flows. This implies that sand topographic features on starved beds are determined by the degree of interference between sand particles. Although the present study deals with simple cases only, this can provide a simplified but effective modeling of the more complicated sediment transport processes controlled by interference due to contact between grains, such as the pulsatory migration of grain-size bimodal mixtures with repetition of clustering and scattering.
NASA Technical Reports Server (NTRS)
Kelley, Mark W; Tolhurst, William H JR
1955-01-01
A wind-tunnel investigation was made to determine the effects of ejecting high-velocity air near the leading edge of plain trailing-edge flaps on a 35 degree sweptback wing. The tests were made with flap deflections from 45 degrees to 85 degrees and with pressure ratios across the flap nozzles from sub-critical up to 2.9. A limited study of the effects of nozzle location and configuration on the efficiency of the flap was made. Measurements of the lift, drag, and pitching moment were made for Reynolds numbers from 5.8 to 10.1x10(6). Measurements were also made of the weight rate of flow, pressure, and temperature of the air supplied to the flap nozzles.The results show that blowing on the deflected flap produced large flap lift increments. The amount of air required to prevent flow separation on the flap was significantly less than that estimated from published two-dimensional data. When the amount of air ejected over the flap was just sufficient to prevent flow separation, the lift increment obtained agreed well with linear inviscid fluid theory up to flap deflections of 60 degrees. The flap lift increment at 85 degrees flap deflection was about 80 percent of that predicted theoretically.With larger amounts of air blown over the flap, these lift increments could be significantly increased. It was found that the performance of the flap was relatively insensitive to the location of the flap nozzle, to spacers in the nozzle, and to flow disturbances such as those caused by leading-edge slats or discontinuities on the wing or flap surfaces. Analysis of the results indicated that installation of this system on an F-86 airplane is feasible.
Effect of long-term successive storm flows on water reclamation plant resilience.
Zhu, Jun-Jie; Anderson, Paul R
2017-03-15
A water reclamation plant (WRP) needs to be resilient to successfully operate through different kinds of perturbations. Perturbations such as storm events, especially long-term successive storm flows, can adversely affect operations. A better understanding of these effects can provide benefits for plant operation, in terms of effluent quality and energy efficiency. However, the concept of resilience for a WRP has not been widely studied, and we are not aware of any studies specifically related to storm flows. In this work we applied measures of resistance and recovery time to quantify resilience, and used a WRP simulation model to investigate how different storm flow characteristics (flowrate and duration) and the amount of aeration influence resilience. Not surprisingly, increasing storm flowrate leads to decreasing resilience. Although the aeration rate plays an important role in determining resilience, there is an aeration threshold (6 m 3 /s for our WRP model); higher aeration rates do not increase resilience. Results suggest that aeration costs could be reduced by as much as 50% while still maintaining the resilience needed to meet effluent quality permit requirements through the perturbations examined in this study. Copyright © 2016 Elsevier Ltd. All rights reserved.
Determining the amount of waste plastics in the feed of Austrian waste-to-energy facilities
Schwarzböck, Therese; Van Eygen, Emile; Rechberger, Helmut; Fellner, Johann
2016-01-01
Although thermal recovery of waste plastics is widely practiced in many European countries, reliable information on the amount of waste plastics in the feed of waste-to-energy plants is rare. In most cases the amount of plastics present in commingled waste, such as municipal solid waste, commercial, or industrial waste, is estimated based on a few waste sorting campaigns, which are of limited significance with regard to the characterisation of plastic flows. In the present study, an alternative approach, the so-called Balance Method, is used to determine the total amount of plastics thermally recovered in Austria’s waste incineration facilities in 2014. The results indicate that the plastics content in the waste feed may vary considerably among different plants but also over time. Monthly averages determined range between 8 and 26 wt% of waste plastics. The study reveals an average waste plastics content in the feed of Austria’s waste-to-energy plants of 16.5 wt%, which is considerably above findings from sorting campaigns conducted in Austria. In total, about 385 kt of waste plastics were thermally recovered in all Austrian waste-to-energy plants in 2014, which equals to 45 kg plastics cap-1. In addition, the amount of plastics co-combusted in industrial plants yields a total thermal utilisation rate of 70 kg cap-1 a-1 for Austria. This is significantly above published rates, for example, in Germany reported rates for 2013 are in the range of only 40 kg of waste plastics combusted per capita. PMID:27474393
Determining the amount of waste plastics in the feed of Austrian waste-to-energy facilities.
Schwarzböck, Therese; Van Eygen, Emile; Rechberger, Helmut; Fellner, Johann
2017-02-01
Although thermal recovery of waste plastics is widely practiced in many European countries, reliable information on the amount of waste plastics in the feed of waste-to-energy plants is rare. In most cases the amount of plastics present in commingled waste, such as municipal solid waste, commercial, or industrial waste, is estimated based on a few waste sorting campaigns, which are of limited significance with regard to the characterisation of plastic flows. In the present study, an alternative approach, the so-called Balance Method, is used to determine the total amount of plastics thermally recovered in Austria's waste incineration facilities in 2014. The results indicate that the plastics content in the waste feed may vary considerably among different plants but also over time. Monthly averages determined range between 8 and 26 wt% of waste plastics. The study reveals an average waste plastics content in the feed of Austria's waste-to-energy plants of 16.5 wt%, which is considerably above findings from sorting campaigns conducted in Austria. In total, about 385 kt of waste plastics were thermally recovered in all Austrian waste-to-energy plants in 2014, which equals to 45 kg plastics cap -1 . In addition, the amount of plastics co-combusted in industrial plants yields a total thermal utilisation rate of 70 kg cap -1 a -1 for Austria. This is significantly above published rates, for example, in Germany reported rates for 2013 are in the range of only 40 kg of waste plastics combusted per capita.
Very low temperature (450 °C) selective epitaxial growth of heavily in situ boron-doped SiGe layers
NASA Astrophysics Data System (ADS)
Aubin, J.; Hartmann, J. M.; Veillerot, M.; Essa, Z.; Sermage, B.
2015-11-01
We have investigated the feasibility of selectively growing SiGe:B layers at 450 °C, 20 Torr in a 300 mm industrial reduced pressure chemical vapor deposition tool. A reduced H2 carrier gas mass-flow has been used in order to have acceptable growth rates at such a temperature, which is very low indeed. We have first of all studied on blanket Si wafers the in situ boron doping of SiGe with Si2H6, GeH4 and B2H6. A growth rate increase by a factor close to 7 together with a Ge concentration decrease from 53% down to 32% occurred as the diborane mass-flow increased. Very high B+ ion concentrations were obtained in layers that were single crystalline and smooth. Their concentration increased almost linearly with the B2H6 mass-flow, from 1.8 up to 8.3 × 1020 cm-3. The associated resistivity dropped from 0.43 down to 0.26 mΩ cm. We have then tested whether or not selectivity versus SiO2 could be achieved by adding various amounts of HCl to Si2H6 + GeH4 +B2H6. Single crystalline growth rates of intrinsic SiGe(:B) on Si were very similar to poly-crystalline growth rates on SiO2-covered substrates irrespective of the HCl flow. Straightforward selectivity was thus not feasible with a co-flow approach. As a consequence, a 450 °C deposition/etch (DE) process was evaluated. Growth occurred at 20 Torr with the above-mentioned chemistry, while the selective etch of poly-SiGe:B versus c-SiGe:B was conducted at 740 Torr with a medium HCl mass-flow (F(HCl)/F(H2) = 0.2) and a high H2 flow. A 2.2 etch selectivity was achieved while retaining single crystalline if slightly rough SiGe:B layers.
Design, Development, and Testing of a Water Vapor Exchanger for Spacecraft Life Support Systems
NASA Technical Reports Server (NTRS)
Izenson, Michael G.; Micka, Daniel J.; Chepko, Ariane B.; Rule, Kyle C.; Anderson, Molly S.
2016-01-01
Thermal and environmental control systems for future exploration spacecraft must meet challenging requirements for efficient operation and conservation of resources. Maximizing the use of regenerative systems and conserving water are critical considerations. This paper describes the design, development, and testing of an innovative water vapor exchanger (WVX) that can minimize the amount of water absorbed in, and vented from, regenerative CO2 removal systems. Key design requirements for the WVX are high air flow capacity (suitable for a crew of six), very high water recovery, and very low pressure losses. We developed fabrication and assembly methods that enable high-efficiency mass transfer in a uniform and stable array of Nafion tubes. We also developed analysis and design methods to compute mass transfer and pressure losses. We built and tested subscale units sized for flow rates of 2 and 5 cu ft/min (3.4–8.5 cu m/hr). Durability testing demonstrated that a stable core geometry was sustained over many humid/dry cycles. Pressure losses were very low (less than 0.5 in. H2O (125 Pa) total) and met requirements at prototypical flow rates. We measured water recovery efficiency across a range of flow rates and humidity levels that simulate the range of possible cabin conditions. We measured water recovery efficiencies in the range of 80 to 90%, with the best efficiency at lower flow rates and higher cabin humidity levels. We compared performance of the WVX with similar units built using an unstructured Nafion tube bundle. The WVX achieves higher water recovery efficiency with nearly an order of magnitude lower pressure drop than unstructured tube bundles. These results show that the WVX provides uniform flow through flow channels for both the humid and dry streams and can meet requirements for service on future exploration spacecraft. The WVX technology will be best suited for long-duration exploration vehicles that require regenerative CO2 removal systems while needing to conserve water.
Solar-Cycle Variation of Subsurface-Flow Divergence: A Proxy of Magnetic Activity?
NASA Astrophysics Data System (ADS)
Komm, R.; Howe, R.; Hill, F.
2017-09-01
We study the solar-cycle variation of subsurface flows from the surface to a depth of 16 Mm. We have analyzed Global Oscillation Network Group (GONG) Dopplergrams with a ring-diagram analysis covering about 15 years and Helioseismic and Magnetic Imager (HMI) Dopplergrams covering more than 6 years. After subtracting the average rotation rate and meridional flow, we have calculated the divergence of the horizontal residual flows from the maximum of Solar Cycle 23 through the declining phase of Cycle 24. The subsurface flows are mainly divergent at quiet regions and convergent at locations of high magnetic activity. The relationship is essentially linear between divergence and magnetic activity at all activity levels at depths shallower than about 10 Mm. At greater depths, the relationship changes sign at locations of high activity; the flows are increasingly divergent at locations with a magnetic activity index (MAI) greater than about 24 G. The flows are more convergent by about a factor of two during the rising phase of Cycle 24 than during the declining phase of Cycle 23 at locations of medium and high activity (about 10 to 40 G MAI) from the surface to at least 10 Mm. The subsurface divergence pattern of Solar Cycle 24 first appears during the declining phase of Cycle 23 and is present during the extended minimum. It appears several years before the magnetic pattern of the new cycle is noticeable in synoptic maps. Using linear regression, we estimate the amount of magnetic activity that would be required to generate the precursor pattern and find that it should be almost twice the amount of activity that is observed.
Du, Qizhen; Jerz, Gerold; Ha, Yangchun; Li, Lei; Xu, Yuanjin; Zhang, Qi; Zheng, Qunxiong; Winterhalter, Peterb; Ito, Yoichiro
2005-05-13
Salicin in the bark extract of Salix alba and amygdalin in the fruit extract of Semen armeniacae were each separated by slow rotary counter-current chromatography (SRCCC). The apparatus was equipped with a 40-L column made of 17 mm i.d. convoluted Teflon tubing. A 500g amount of crude extract containing salicin at 13.5% was separated yielding 63.5 g of salicin at 95.3% purity in 20h using methyl tert-butyl ether-l-butanol (1:3) saturated by methanol-water (1:5) as a stationary phase and methanol-water (1:5) saturated by methyl tert-butyl ether-1-butanol (1:3) as a mobile phase. A 400g amount of crude extract containing amygdalin at 55.3% was isolated to yield 221.2g of amygdalin at 94.1% purity in 19h using ethyl acetate-1-butanol (1:2) saturated by water as a stationary phase and water saturated by ethyl acetate-1-butanol (1:2) as a mobile phase. The flow rate of the mobile phase was 50 ml/min. The results show that industrial SRCCC separation of salicin and amygdalin is feasible using a larger column at a higher flow rate of the mobile phase.
Patterns of brittle deformation under extension on Venus
NASA Technical Reports Server (NTRS)
Neumann, G. A.; Zuber, M. T.
1994-01-01
The development of fractures at regular length scales is a widespread feature of Venusian tectonics. Models of lithospheric deformation under extension based on non-Newtonian viscous flow and brittle-plastic flow develop localized failure at preferred wavelengths that depend on lithospheric thickness and stratification. The characteristic wavelengths seen in rift zones and tessera can therefore provide constraints on crustal and thermal structure. Analytic solutions were obtained for growth rates in infinitesimal perturbations imposed on a one-dimensional, layered rheology. Brittle layers were approximated by perfectly-plastic, uniform strength, overlying ductile layers exhibiting thermally-activated power-law creep. This study investigates the formation of faults under finite amounts of extension, employing a finite-element approach. Our model incorporates non-linear viscous rheology and a Coulomb failure envelope. An initial perturbation in crustal thickness gives rise to necking instabilities. A small amount of velocity weakening serves to localize deformation into planar regions of high strain rate. Such planes are analogous to normal faults seen in terrestrial rift zones. These 'faults' evolve to low angle under finite extension. Fault spacing, orientation and location, and the depth to the brittle-ductile transition, depend in a complex way on lateral variations in crustal thickness. In general, we find that multiple wavelengths of deformation can arise from the interaction of crustal and mantle lithosphere.
Redesigned Human Metabolic Simulator
NASA Technical Reports Server (NTRS)
Duffield, Bruce; Jeng, Frank; Lange, Kevin
2008-01-01
A design has been formulated for a proposed improved version of an apparatus that simulates atmospheric effects of human respiration by introducing controlled amounts of carbon dioxide, water vapor, and heat into the air. Denoted a human metabolic simulator (HMS), the apparatus is used for testing life-support equipment when human test subjects are not available. The prior version of the HMS, to be replaced, was designed to simulate the respiratory effects of as many as four persons. It exploits the catalytic combustion of methyl acetate, for which the respiratory quotient (the molar ratio of carbon dioxide produced to oxygen consumed) is very close to the human respiratory quotient of about 0.86. The design of the improved HMS provides for simulation of the respiratory effects of as many as eight persons at various levels of activity. The design would also increase safety by eliminating the use of combustion. The improved HMS (see figure) would include a computer that would exert overall control. The computer would calculate the required amounts of oxygen removal, carbon dioxide addition, water addition, and heat addition by use of empirical equations for metabolic profiles of respiration and heat. A blower would circulate air between the HMS and a chamber containing a life-support system to be tested. With the help of feedback from a mass flowmeter, the blower speed would be adjusted to regulate the rate of flow according to the number of persons to be simulated and to a temperature-regulation requirement (the air temperature would indirectly depend on the rate of flow, among other parameters). Oxygen would be removed from the circulating air by means of a commercially available molecular sieve configured as an oxygen concentrator. Oxygen, argon, and trace amounts of nitrogen would pass through a bed in the molecular sieve while carbon dioxide, the majority of nitrogen, and other trace gases would be trapped by the bed and subsequently returned to the chamber. If, as recommended, the oxygen concentrator were of a rotating twelve-bed design, then variations in the product stream could be made very small. Carbon dioxide would be added directly to the circulating air by simple injection from a supply tank. The rate of injection would be maintained at the required rate by use of a mass flowmeter/controller. In the same way, nitrogen would be added to make up for the small amount of nitrogen lost through the oxygen concentrator. Water vapor would be added to the circulating air by heating the corresponding required flow of water to steam in a heat exchanger. More heat, required to complete the simulation of the thermal effect of respiration, would be added through another heat exchanger. Heat would be supplied to both heat exchangers via a hot-oil loop.
Combustion of textile residues in a packed bed
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ryu, Changkook; Phan, Anh N.; Sharifi, Vida N.
2007-08-15
Textile is one of the main components in the municipal waste which is to be diverted from landfill for material and energy recovery. As an initial investigation for energy recovery from textile residues, the combustion of cotton fabrics with a minor fraction of polyester was investigated in a packed bed combustor for air flow rates ranging from 117 to 1638 kg/m{sup 2} h (0.027-0.371 m/s). Tests were also carried out in order to evaluate the co-combustion of textile residues with two segregated waste materials: waste wood and cardboard. Textile residues showed different combustion characteristics when compared to typical waste materialsmore » at low air flow rates below 819 kg/m{sup 2} h (0.186 m/s). The ignition front propagated fast along the air channels randomly formed between packed textile particles while leaving a large amount of unignited material above. This resulted in irregular behaviour of the temperature profile, ignition rate and the percentage of weight loss in the ignition propagation stage. A slow smouldering burn-out stage followed the ignition propagation stage. At air flow rates of 1200-1600 kg/m{sup 2} h (0.272-0.363 m/s), the bed had a maximum burning rate of about 240 kg/m{sup 2} h consuming most of the combustibles in the ignition propagation stage. More uniform combustion with an increased burning rate was achieved when textile residues were co-burned with cardboard that had a similar bulk density. (author)« less
Cikirikcioglu, Mustafa; Cikirikcioglu, Y Banu; Khabiri, Ebrahim; Djebaili, M Karim; Kalangos, Afksendiyos; Walpoth, Beat H
2006-01-01
Intra-operative flow measurement during coronary or peripheral bypass operations is helpful for ruling out technical failures and for prediction of complication and patency rates. Preclinical validation of the flowmeters is required in order to rely on the intra-operatively measured results. The aim of this study is to evaluate a new "dual beam Doppler" blood flowmeter before clinical application and to compare it with the established "transit time flow measure-ment" technique in an artificial circuit. Measurements were performed in an experimental flow model using pig blood and pig arteries. Three different flowmeters were used: Quantix OR (dual beam doppler flowmeter), CardioMed (transit time flowmeter), and Transonic (transit time flowmeter). Three validation tests were performed to assess correlation, precision, and repeatability of devices. (1) Correlation and agreement analysis was performed with various flow amounts (10-350 mL/min) (n = 160). (2) Device reproducibility and measurement stability were tested with a constant flow (flow amount = 300 mL/min) (n = 30). (3) A user accuracy test (intra- and inter-observer variability) was performed by 5 different observers with a constant flow (flow amount = 205 mL/min) (n = 75). Time collected true flow was used as a reference method in all steps and all tests were performed in a blind manner. Results are shown as mean values +/- standard deviations. Pear-son's correlation and Bland-Altman plot analyses were used to compare measurements. The mean flow was 167 +/- 98 mL/min for true flow and 162 +/- 94 mL/min, 165 +/- 94 mL/min, and 166 +/- 100 mL/min for Quantix OR, CardioMed, and Transonic, respectively. Correlation coefficients between Quantix OR, Medi-Stim, Transonic, and time collected true flow were over 0.98 (P = .01). Most of the measured results ( > 90%) were between +/- 1.96 SD agreement limits in Bland and Altman plot analysis. All devices showed good results in the reproducibility test. During the user accuracy test, larger variance changes were observed between intra- and inter-observer results with the dual beam Doppler flowmeter compared to the 2 used transit time flowmeters when used for single sided vessel access without stabilization device (available from the manufacturer). All 3 tested flowmeters showed an excellent correlation to the true flow in an artificial circuit and the accuracy of the tested devices was within agreement limits. Reproducibility of all devices was good and linear. The new dual beam Doppler flow measurement technique compares favorably to the classic transit time method. Clinical use may depend on operator, location, and condition, thus more studies may be required to ensure uniform results using the currently available blood flow measurement devices.
"Batch" kinetics in flow: online IR analysis and continuous control.
Moore, Jason S; Jensen, Klavs F
2014-01-07
Currently, kinetic data is either collected under steady-state conditions in flow or by generating time-series data in batch. Batch experiments are generally considered to be more suitable for the generation of kinetic data because of the ability to collect data from many time points in a single experiment. Now, a method that rapidly generates time-series reaction data from flow reactors by continuously manipulating the flow rate and reaction temperature has been developed. This approach makes use of inline IR analysis and an automated microreactor system, which allowed for rapid and tight control of the operating conditions. The conversion/residence time profiles at several temperatures were used to fit parameters to a kinetic model. This method requires significantly less time and a smaller amount of starting material compared to one-at-a-time flow experiments, and thus allows for the rapid generation of kinetic data. Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
How fast can your company afford to grow?
Churchill, N C; Mullins, J W
2001-05-01
Everyone knows that starting a business requires cash, and growing a business requires even more. But few people understand that a profitable company that tries to grow too fast can run out of cash even if its products are great successes. So a big challenge for managers of any growing concern is to strike the proper balance between consuming cash and generating it. Authors Neil Churchill and John Mullins offer a framework to help identify and manage the level of growth that a company's cash flow can support. They present a formula to calculate an organization's self-financeable growth (SFG) rate, taking into account three critical factors: a company's operating cash cycle--the amount of time the company's money is tied up in inventory and other current assets before customers pay for goods and services; the amount of cash needed to finance each dollar of sales; and the amount of cash generated by each dollar of sales. The authors offer a detailed hypothetical example that carefully considers these three factors; they then illustrate how a company can influence its SFG rate by carefully managing some combination of those factors--that is, some mix of speeding cash flow, reducing costs, and raising prices. They expand on the original example by showing how to include income taxes and depreciation; plan for asset replacement; and identify which one of multiple product lines holds the greatest growth potential. The authors also discuss how various kinds of businesses--manufacturing firms, importers, and service companies--differ greatly in their abilities to finance growth from internally generated funds.
Numerical modelling study of gully recharge and debris flows in Haida Gwaii, British Columbia
NASA Astrophysics Data System (ADS)
Martin, Yvonne; Johnson, Edward; Chaikina, Olga
2015-04-01
In high mountains, debris flows are a major process responsible for transferring sediment to more downstream fluvial reaches. This sediment transfer begins on mountain hillslopes where various mass wasting processes move sediment from hillslopes to uppermost reaches of the channel system (these reaches are herein referred to as gullies and only experience water flow during high intensity precipitation events). Sediment recharge into gullies, which has received minimal attention in the scientific literature, refers to the transfer of sediment and other debris from surrounding hillslopes into gullies (Jakob and Oden, 2005). Debris flow occurrence and debris flow volumes depend on some precipitation threshold as well as volumes of material contained in the particular gully. For example, if one debris flow has removed all of the accumulated material from the gully, then any subsequent debris flow will be smaller if enough time has not yet passed for notable sediment recharge. Herein, we utilize the numerical model of landscape development, LandMod (Martin, 1998; Dadson and Church, 2005; Martin, 2007), to explore connections between hillslope processes, gully recharge rates, and transfer of sediment to downstream channel reaches in the Haida Gwaii, British Columbia. Hillslope processes in the model include shallow landsliding, bedrock failures and weathering. The updated debris flow algorithm is based on extensive field data available for debris flows in Haida Gwaii (e.g., Rood, 1984; Oden, 1994; Jakob and Oden, 2005), as well as theoretical considerations based on debris flow studies. The most significant model extension is the calculation of gully recharge rates; for each gully, the total accumulated sediment in gullies at each time step is determined using a power-law relation for area-normalized recharge rate versus elapsed time since the last debris flow. Thus, when the stochastic driver for debris flow occurrence triggers an event, the amount of stored material is known and can be transferred and deposited along the channel system. Results show that the size distribution of debris flows and sediment transfers from gullies to downstream reaches are modified by the inclusion of a module that accounts for sediment recharge when compared to model runs that do not consider gully recharge.
NASA Astrophysics Data System (ADS)
Masteller, C.; Finnegan, N. J.
2016-12-01
Memory is preserved in rivers through the sorting and arrangement of grains on their beds, which reflect previous flow conditions. Manifestations of this phenomenon include observed hysteresis in bedload rating curves (e.g., Moog and Whiting, 1998; Reid et al., 1985) and correlations between the stage at the start of a transport event and the stage at the end of transport during a previous event (Turowski et al., 2011). This observed history dependence represents a key difficulty in the accurate prediction of bedload transport rates. To begin to systematically explore these memory effects on fluvial bedload transport, we experimentally examined how a gravel bed river responds to variations in prior stress history. Specifically, we compare the response of the grain-scale topography of a gravel riverbed to both below and above threshold flow conditions. We find that under low flow, when no sediment transport occurs, the bed compacts as the highest protruding grains pivot into low elevation pockets. This reorganization appears to occur logarithmically with low flow duration, making it analogous to compaction observed in dry granular flows subjected to agitation. The amount of prior compaction affects bedload transport rates at the onset of above threshold flow, with more compact beds yielding less bedload flux. In contrast, we find that under sediment-transporting flows, the bed dilates because grains are re-deposited in relatively precarious positions. During the same applied transport flow, we observe that the most pronounced dilation occurs when the initial bed is the most compact, suggesting that the potential for dilation is related to the degree of previous compaction. These observations highlight that a gravel bed experiences two different behaviors, compaction under low shear stresses, and dilation under high, sediment transporting, shear stresses. This observation is consistent with previous studies on the compaction and dilation of granular media, as well as flume experiments conducted using glass beads. Further, this study highlights the varying response of grain-scale topography and bedload transport rates to prior flow and bed conditions, demonstrating history dependence in fluvial systems.
Ozone Disinfection of Vibrio vulnificus in Shrimp Pond Water
NASA Astrophysics Data System (ADS)
Dyah Pita Rengga, Wara; Cahya Julyta Putri, Echa; Wulansarie, Ria; Suryanto, Agus
2018-03-01
One variety of shrimp, L.Vanamei, often uses brackish water during the operation in the shrimp pond. Chlorination and ultraviolet are usually used for disinfection of brackish water. However, it is ineffective and forms sediment in the water distribution. It can be a negative impact on the water quality cause a contamination on the shrimp, so the farmers might have loss of profit because Vibrio vulnificus causes infection and dead on the shrimp. It affects the safety of consumers and should be minimized. The purpose of this study is to reduce the number of V. vulnificus bacteria in the pond water. The water was put in the storage tanks then pumped to filter out the impurities of the water. Furthermore, the water set the flow rate in 1 LPM, 2 LPM, and 3 LPM. After that, the ozone was injected to the water flow to sterilize the V. vulnificus bacteria. Finally, the water was returned to the original tank. The water from the tank was taken through a valve and analyzed in 0, 3, 7, 12, 18, 24, 30 minutes. The sample was analyzed immediately using a Total Plate Count method to determine the number of V. vulnificus bacteria in the shrimp pond water. The flow rate shows that the longer time of ozone made a lower amount of Vibrio v. bacteria. In 2 LPM water, it shows the optimum results of V. vulnificus. bacteria reduction for 88.1% compared to the flow rate of 1 LPM and 3 LPM with the bacteria reduction of 68,8% and 70.6%. This study shows that the ozone with a flow rate of 2 LPM circulation is the most effective method to help reducing the number of V. vulnificus in brackish water distribution system in the shrimp environment and potentially as a disinfectant.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xia, Yan; Li, Ming; Kučerka, Norbert
We have designed and constructed a temperature-controllable shear flow cell for in-situ study on flow alignable systems. The device has been tested in the neutron diffraction and has the potential to be applied in the small angle neutron scattering configuration to characterize the nanostructures of the materials under flow. The required sample amount is as small as 1 ml. The shear rate on the sample is controlled by the flow rate produced by an external pump and can potentially vary from 0.11 to 3.8 × 10{sup 5} s{sup −1}. Both unidirectional and oscillational flows are achievable by the setting ofmore » the pump. The instrument is validated by using a lipid bicellar mixture, which yields non-alignable nanodisc-like bicelles at low T and shear-alignable membranes at high T. Using the shear cell, the bicellar membranes can be aligned at 31 °C under the flow with a shear rate of 11.11 s{sup −1}. Multiple high-order Bragg peaks are observed and the full width at half maximum of the “rocking curve” around the Bragg’s condition is found to be 3.5°–4.1°. It is noteworthy that a portion of the membranes remains aligned even after the flow stops. Detailed and comprehensive intensity correction for the rocking curve has been derived based on the finite rectangular sample geometry and the absorption of the neutrons as a function of sample angle [See supplementary material at http://dx.doi.org/10.1063/1.4908165 for the detailed derivation of the absorption correction]. The device offers a new capability to study the conformational or orientational anisotropy of the solvated macromolecules or aggregates induced by the hydrodynamic interaction in a flow field.« less
Revisiting flow maps: a classification and a 3D alternative to visual clutter
NASA Astrophysics Data System (ADS)
Gu, Yuhang; Kraak, Menno-Jan; Engelhardt, Yuri
2018-05-01
Flow maps have long been servicing people in exploring movement by representing origin-destination data (OD data). Due to recent developments in data collecting techniques the amount of movement data is increasing dramatically. With such huge amounts of data, visual clutter in flow maps is becoming a challenge. This paper revisits flow maps, provides an overview of the characteristics of OD data and proposes a classification system for flow maps. For dealing with problems of visual clutter, 3D flow maps are proposed as potential alternative to 2D flow maps.
NASA Astrophysics Data System (ADS)
Webb, C. H.; Foglia, L.; Fogg, G. E.; McClain, J.
2017-12-01
Precipitation in mountainous systems is responsible for much of the world's freshwater supply. Volcanic mountains in particular may have the capacity to store large amounts of groundwater, due to the relatively high permeability of volcanic rocks as compared to fractured crystalline rocks. These qualities make volcanic aquifers likely candidates for laterally extensive deep groundwater systems. However, the depth extent of these aquifers is not well understood and has been little studied, due to the dearth of well data in most mountain systems. When determining a water budget, especially for mountainous regions, it is necessary to understand the extent of the entire system, including the deep components. Mount Shasta of the California cascade volcanoes is one potential case of a deep groundwater system with the capacity to store significant amounts of water. In order to develop a conceptual model of the role of deep and regional groundwater flow in the Mt. Shasta groundwater system, the region was modeled using MODFLOW_2005, the finite difference flow model developed by USGS. The model was constrained using SRTM topography data, spring flow rates, PRISM precipitation rates, and well log levels. Geologic cross sections and gravity data were referenced in order to create a realistic estimate of the aquifer's structure down to 6km in depth. The aquifer stratigraphy was then represented by using 6 layers with 2-4 zones of hydraulic conductivity per layer to account for both vertical and lateral differences in lithology as well as decreasing permeability with depth. These hydraulic conductivity parameters of the model were varied using inverse modeling (UCODE_2014) to determine which layers and zones could support flow and still produce results consistent with existing well logs. Depth of flow was also corroborated with resistivity data collected in Shasta Valley using magnetotelluric (MT) soundings. Depths with comparatively low electrical resistivity were assumed to be aquifer units, and zones with high resistivity were assumed to be aquitards. By performing MT soundings in multiple locations and dividing the model into zones, this model tests both the maximum depth of flow as well as how that depth varies with lithology and geographical location.
Characteristic changes of saliva and taste in burning mouth syndrome patients.
Imura, Hiroko; Shimada, Masahiko; Yamazaki, Yoko; Sugimoto, Kumiko
2016-03-01
Burning mouth syndrome (BMS) is characterized by chronic pain with a burning sensation of the tongue and oral mucosa and reported to be often accompanied by subjective xerostomia and dysgeusia. Since the etiology of BMS has not been elucidated, to understand the characteristics of BMS, we measured some components of saliva and taste sensitivity and compared the measured values between BMS and healthy subjects. Unstimulated saliva was collected from 15 female BMS patients and 30 healthy women. The flow rate, viscosity (spinnability) and concentration of secretory IgA (SIgA) of saliva and serum antioxidant capacity were measured. The recognition thresholds for sweet, salty, sour, bitter, and umami tastes were measured by whole-mouth method. The statistical analyses were performed using Student's t-test, and P < 0.05 was considered to be significant. In BMS group, the flow rate of saliva was significantly lower and the spinnability was significantly higher compared with healthy group. The secreted amount of SIgA per min and serum antioxidant capacity was significantly lower in the patients. The threshold for sourness in patients was significantly higher, while those for other tastes did not differ from healthy group. BMS patients showed lower salivary flow and higher salivary spinnability. These results together with decreased SIgA amount, suggest that BMS may be relevant to the deterioration of salivary condition, which could in turn affect taste function. Furthermore, the lower antioxidant capacity in patient's serum suggests that it can serve as a diagnostic tool for BMS. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Chung, Ji-Woo; Kim, Kyung-Min; Yoon, Tae-Ung; Kim, Seung-Ik; Jung, Tae-Sung; Han, Sang-Sup; Bae, Youn-Sang
2017-12-22
A novel power partial-discard (PPD) strategy was developed as a variant of the partial-discard (PD) operation to further improve the separation performance of the simulated moving bed (SMB) process. The PPD operation varied the flow rates of discard streams by introducing a new variable, the discard amount (DA) as well as varying the reported variable, discard length (DL), while the conventional PD used fixed discard flow rates. The PPD operations showed significantly improved purities in spite of losses in recoveries. Remarkably, the PPD operation could provide more enhanced purity for a given recovery or more enhanced recovery for a given purity than the PD operation. The two variables, DA and DL, in the PPD operation played a key role in achieving the desired purity and recovery. The PPD operations will be useful for attaining high-purity products with reasonable recoveries. Copyright © 2017 Elsevier B.V. All rights reserved.
Development and testing of aluminum micro channel heat sink
NASA Astrophysics Data System (ADS)
Kumaraguruparan, G.; Sornakumar, T.
2010-06-01
Microchannel heat sinks constitute an innovative cooling technology for the removal of a large amount of heat from a small area and are suitable for electronics cooling. In the present work, Tool Steel D2 grade milling slitting saw type plain milling cutter is fabricated The microchannels are machined in aluminum work pieces to form the microchannel heat sink using the fabricated milling cutter in an horizontal milling machine. A new experimental set-up is fabricated to conduct the tests on the microchannel heat sink. The heat carried by the water increases with mass flow rate and heat input. The heat transfer coefficient and Nusselt number increases with mass flow rate and increased heat input. The pressure drop increases with Reynolds number and decreases with input heat. The friction factor decreases with Reynolds number and decreases with input heat. The thermal resistance decreases with pumping power and decreases with input heat.
Miao, Bo; Meng, Ping; Zhang, Jin Song; He, Fang Jie; Sun, Shou Jia
2017-07-18
The water sources and transpiration of poplar trees in Zhangbei County were measured using stable hydrogen isotope and thermal dissipation method. The differences in water relationships between dieback and non-dieback poplar trees were analyzed. The results showed that the dieback trees mainly used shallow water from 0-30 cm soil layer during growing season while the non-dieback trees mainly used water from 30-80 cm soil layer. There was a significant difference in water source between them. The non-dieback trees used more water from middle and deep soil layers than that of the dieback trees during the dry season. The percentage of poplar trees using water from 0-30 cm soil layer increased in wet season, and the increase of dieback trees was higher than that of non-dieback trees. The contributions of water from 30-180 cm soil layer of dieback and non-dieback trees both decreased in wet season. The sap flow rate of non-dieback trees was higher than that of dieback trees. There was a similar variation tend of sap flow rate between dieback and non-dieback trees in different weather conditions, but the start time of sap flow of non-dieback trees was earlier than that of dieback trees. Correlation analysis showed that the sap flow rate of either dieback or non-dieback poplar trees strongly related to soil temperature, wind speed, photosynthetically active radiation, relative humidity and air temperature. The sap flow rate of die-back poplar trees strongly negatively related to soil temperature and relative humidity, and strongly positively related to the other factors. The sap flow rate of non-dieback poplar trees only strongly negatively related to relative humidity but positively related to the other factors. The results revealed transpiration of both poplar trees was easily affected by environmental factors. The water consumption of dieback trees was less than non-dieback trees because the cumulative sap flow amount of dieback trees was lower. Reduced transpiration of dieback trees couldn't help to prevent poplar forest declining due to shallow water source.
NASA Astrophysics Data System (ADS)
Sklaveniti, S.; Locoge, N.; Dusanter, S.; Leonardis, T.; Lew, M.; Bottorff, B.; Sigler, P. S. R.; Stevens, P. S.; Wood, E. C. D.; Kundu, S.; Gentner, D. R.
2015-12-01
Ozone is a greenhouse gas and a primary constituent of urban smog, irritating the respiratory system and damaging the vegetation. The current understanding of ozone chemistry in the troposphere indicates that net ozone production P(O3) occurs when peroxy radicals (HO2+RO2) react with NO producing NO2, whose photolysis leads to O3 formation. P(O3) values can be calculated from peroxy radical concentrations, either from ambient measurements or box model outputs. These two estimation methods often disagree for NOx mixing ratios higher than a few ppb, questioning our ability to measure peroxy radicals under high NOx conditions or indicating that there are still unknowns in our understanding of the radical and ozone production chemistry. Direct measurements of ozone production rates will help to address this issue and improve air quality regulations. We will present the development of an instrument for direct measurements of ozone production rates (OPR). The OPR instrument consists of three parts: (i) two quartz flow tubes sampling ambient air ("Ambient" and "Reference" flow tube), (ii) an O3-to-NO2 conversion unit, and (iii) a Cavity Attenuated Phase Shift (CAPS) monitor to measure NO2. The air in the Ambient flow tube undergoes the same photochemistry as in ambient air, while the Reference flow tube is covered by a UV filter limiting the formation of ozone. Exiting the flow tubes, ozone is converted into NO2 and the sum O3+NO2 (Ox) is measured by the CAPS monitor. The difference in Ox between the two flow tubes divided by the residence time yields the Ox production rate, P(Ox). P(O3) is assumed to be equal to P(Ox) when NO2 is efficiently photolyzed during daytime. We will present preliminary results from the Indiana Radical, Reactivity and Ozone Production Intercomparison (IRRONIC) campaign in Bloomington, Indiana, during July 2015, where ozone production rates were measured by introducing various amounts of NO inside the flow tubes to investigate the ozone production sensitivity.
NASA Astrophysics Data System (ADS)
Mitter, H.; Böse, N.; Benyon, R.; Vicente, T.
2012-09-01
During calibration of precision optical dew-point hygrometers (DPHs), it is usually necessary to take into account the pressure drop induced by the gas flow between the "point of reference" and the "point of use" (mirror or measuring head of the DPH) either as a correction of the reference dew-point temperature or as part of the uncertainty estimation. At dew-point temperatures in the range of ambient temperature and below, it is sufficient to determine the pressure drop for the required gas flow, and to keep the volumetric flow constant during the measurements. In this case, it is feasible to keep the dry-gas flow into the dew-point generator constant or to measure the flow downstream the DPH at ambient temperature. In normal operation, at least one DPH in addition to the monitoring DPH are used, and this operation has to be applied to each instrument. The situation is different at high dew-point temperatures up to 95 °C, the currently achievable upper limit reported in this paper. With increasing dew-point temperatures, the reference gas contains increasing amounts of water vapour and a constant dry-gas flow will lead to a significant enhanced volume flow at the conditions at the point of use, and therefore, to a significantly varying pressure drop depending on the applied dew-point temperature. At dew-point temperatures above ambient temperature, it is also necessary to heat the reference gas and the mirror head of the DPH sufficiently to avoid condensation which will additionally increase the volume flow and the pressure drop. In this paper, a method is provided to calculate the dry-gas flow rate needed to maintain a known wet-gas flow rate through a chilled mirror for a range of temperature and pressures.
Composition and luminescence studies of InGaN epilayers grown at different hydrogen flow rates
NASA Astrophysics Data System (ADS)
Taylor, E.; Fang, F.; Oehler, F.; Edwards, P. R.; Kappers, M. J.; Lorenz, K.; Alves, E.; McAleese, C.; Humphreys, C. J.; Martin, R. W.
2013-06-01
Indium gallium nitride (InxGa1 - xN) is a technologically important material for many optoelectronic devices, including LEDs and solar cells, but it remains a challenge to incorporate high levels of InN into the alloy while maintaining sample quality. A series of InGaN epilayers was grown with different hydrogen flow rates (0-200 sccm) and growth temperatures (680-750 °C) to obtain various InN fractions and bright emission in the range 390-480 nm. These 160-nm thick epilayers were characterized through several compositional techniques (wavelength dispersive x-ray spectroscopy, x-ray diffraction, Rutherford backscattering spectrometry) and cathodoluminescence hyperspectral imaging. The compositional analysis with the different techniques shows good agreement when taking into account compositional gradients evidenced in these layers. The addition of small amounts of hydrogen to the gas flow at lower growth temperatures is shown to maintain a high surface quality and luminescence homogeneity. This allowed InN fractions of up to ˜16% to be incorporated with minimal peak energy variations over a mapped area while keeping a high material quality.
Color and Vector Flow Imaging in Parallel Ultrasound With Sub-Nyquist Sampling.
Madiena, Craig; Faurie, Julia; Poree, Jonathan; Garcia, Damien; Garcia, Damien; Madiena, Craig; Faurie, Julia; Poree, Jonathan
2018-05-01
RF acquisition with a high-performance multichannel ultrasound system generates massive data sets in short periods of time, especially in "ultrafast" ultrasound when digital receive beamforming is required. Sampling at a rate four times the carrier frequency is the standard procedure since this rule complies with the Nyquist-Shannon sampling theorem and simplifies quadrature sampling. Bandpass sampling (or undersampling) outputs a bandpass signal at a rate lower than the maximal frequency without harmful aliasing. Advantages over Nyquist sampling are reduced storage volumes and data workflow, and simplified digital signal processing tasks. We used RF undersampling in color flow imaging (CFI) and vector flow imaging (VFI) to decrease data volume significantly (factor of 3 to 13 in our configurations). CFI and VFI with Nyquist and sub-Nyquist samplings were compared in vitro and in vivo. The estimate errors due to undersampling were small or marginal, which illustrates that Doppler and vector Doppler images can be correctly computed with a drastically reduced amount of RF samples. Undersampling can be a method of choice in CFI and VFI to avoid information overload and reduce data transfer and storage.
NASA Astrophysics Data System (ADS)
Gazeli, K.; Bauville, G.; Fleury, M.; Jeanney, P.; Neveu, O.; Pasquiers, S.; Santos Sousa, J.
2018-06-01
This work presents spatial (axial-z and transversal-y) and temporal distributions of Ar(1s5) metastable absolute densities in an atmospheric pressure argon micro-plasma jet impinging on an ungrounded glass surface. Guided streamers are generated with a DBD device driven by pulsed positive high voltages of 6 kV in amplitude, 224 +/- 3 ns in FWHM and 20 kHz in frequency. The argon flow rate is varied between 200 and 600 sccm. The glass plate is placed at 5 mm away from the reactor’s nozzle and perpendicular to the streamers propagation. At these conditions, a diffuse stable discharge is established after the passage of the streamers allowing the quantification of the Ar(1s5) absolute density by means of a conventional TDLAS technique coupled with emission spectroscopy and ICCD imaging. The good reproducibility of the absorption signals is demonstrated. The experiments show the strong dependence of the maximum density ({0.5-4}× {10}13 {{{cm}}}-3) on the gas flow rate and the axial and transversal position. At 200 sccm, high maximum densities (> 2.4× {10}13 {{{cm}}}-3) are obtained in a small area close to the plasma source, while with increasing flow rate this area expands towards the glass plate. In the transversal direction, density maxima are obtained in a small zone around the propagation axis of the streamers. Finally, a noticeable increase is measured on the Ar(1s5) effective lifetime close to the glass surface by varying the flow rate from 200 to 600 sccm. In overall, the effective lifetime varies between ∼25 and ∼550 ns, depending on the gas flow rate and the values of z and y coordinates. The results obtained suggest that the present system can be implemented in various applications and particularly in what concerns the detection of weakly volatile organic compounds present in trace amounts on different surfaces.
Modification and performance evaluation of a mono-valve engine
NASA Astrophysics Data System (ADS)
Behrens, Justin W.
A four-stroke engine utilizing one tappet valve for both the intake and exhaust gas exchange processes has been built and evaluated. The engine operates under its own power, but has a reduced power capacity than the conventional 2-valve engine. The reduction in power is traced to higher than expected amounts of exhaust gases flowing back into the intake system. Design changes to the cylinder head will fix the back flow problems, but the future capacity of mono-valve engine technology cannot be estimated. The back flow of exhaust gases increases the exhaust gas recirculation (EGR) rate and deteriorates combustion. Intake pressure data shows the mono-valve engine requires an advanced intake valve closing (IVC) time to prevent back flow of charge air. A single actuation camshaft with advanced IVC was tested in the mono-valve engine, and was found to improve exhaust scavenging at TDC and nearly eliminated all charge air back flow at IVC. The optimum IVC timing is shown to be approximately 30 crank angle degrees after BDC. The mono-valve cylinder head utilizes a rotary valve positioned above the tappet valve. The open spaces inside the rotary valveand between the rotary valve and tappet valve represent a common volume that needs to be reduced in order to reduce the base EGR rate. Multiple rotary valve configurations were tested, and the size of the common volume was found to have no effect on back flow but a direct effect on the EGR rate and engine performance. The position of the rotary valve with respect to crank angle has a direct effect on the scavenging process. Optimum scavenging occurs when the intake port is opened just after TDC.
NASA Astrophysics Data System (ADS)
Lee, Harry; Wen, Baole; Doering, Charles
2017-11-01
The rate of viscous energy dissipation ɛ in incompressible Newtonian planar Couette flow (a horizontal shear layer) imposed with uniform boundary injection and suction is studied numerically. Specifically, fluid is steadily injected through the top plate with a constant rate at a constant angle of injection, and the same amount of fluid is sucked out vertically through the bottom plate at the same rate. This set-up leads to two control parameters, namely the angle of injection, θ, and the Reynolds number of the horizontal shear flow, Re . We numerically implement the `background field' variational problem formulated by Constantin and Doering with a one-dimensional unidirectional background field ϕ(z) , where z aligns with the distance between the plates. Computation is carried out at various levels of Re with θ = 0 , 0 .1° ,1° and 2°, respectively. The computed upper bounds on ɛ scale like Re0 as Re > 20 , 000 for each fixed θ, this agrees with Kolmogorov's hypothesis on isotropic turbulence. The outcome provides new upper bounds to ɛ among any solution to the underlying Navier-Stokes equations, and they are sharper than the analytical bounds presented in Doering et al. (2000). This research was partially supported by the NSF Award DMS-1515161, and the University of Michigan's Rackham Graduate Student Research Grant.
[Function of alveoles as a result of evolutionary development of respiratory system in mammals].
Ivanov, K P
2013-01-01
Reaction of hemoglobin oxygenation is known to occur for 40 femtoseconds (40 x 10(-15) s). However, the process of oxygen diffusion to hemoglobin under physiologic conditions decelerated this reaction approximately billion times. In mammalian lungs, blood is moving at a high rate and in a relatively high amount. The human lung mass is as low as 600 g, but the complete cardiac output approaches 6 1/min. In rat, from 20 to 40 ml of blood is passed for q min through the lung whose mass is about 1.5 g. Such blood flow rate is possible, as in lungs of high animals there exists a dense network of relatively large microvessels with diameter from 20 to 40 microm and more. In spite of a large volume and a high blood flow rate hampering oxygen diffusion, the complete blood oxygenation occurs in lung alveoli. This is due to peculiar mechanisms that facilitate markedly the oxygen diffusion and that developed in alveoli of mammals in the course of many million years of evolution of their respiratory system. Thus, alveolus is not a bubble with air, but a complex tool of fight with inertness of diffusion. It is interesting that in lungs of the low vertebrates, neither such system of blood vessels nor alveoli exist, and their blood flow rate is much lower than in mammals.
Fukui, M
2004-04-01
The radioactive gas 41Ar has been produced at high concentration by neutron activation near the reactor core in the Kyoto University Research Reactor. A pipe line for an exhaust stream, so-called sweep gas, was fabricated at the construction of the reactor in 1964 in order to exhale 41Ar from the facilities above to the environment. Other exhaust lines with decay tanks were established separately from the sweep line for both the cold neutron source in 1986 and the heavy-water tank in 1996, respectively, because a higher amount of 41Ar was thought to be produced from these facilities due to the improvement. As a result, a slight change in the flow rate of the exhaust was found to have a great deal of influence on both the 41Ar concentration in the reactor room and the rate of emission from the stack. By monitoring the exhaust air from the decay tanks, the mechanism for decreasing the emission was clarified together with identifying an obstacle, i.e., the condensate against the steady state flow, formed in the exhaust pipe. By setting the flow rate suitably in the exhaust line, the rate of 41Ar emission from the biological shielding into both the work place in the reactor room and the environment has been controlled as low as reasonably achievable.
The Effect of modeled recharge distribution on simulated groundwater availability and capture
Tillman, Fred D.; Pool, Donald R.; Leake, Stanley A.
2015-01-01
Simulating groundwater flow in basin-fill aquifers of the semiarid southwestern United States commonly requires decisions about how to distribute aquifer recharge. Precipitation can recharge basin-fill aquifers by direct infiltration and transport through faults and fractures in the high-elevation areas, by flowing overland through high-elevation areas to infiltrate at basin-fill margins along mountain fronts, by flowing overland to infiltrate along ephemeral channels that often traverse basins in the area, or by some combination of these processes. The importance of accurately simulating recharge distributions is a current topic of discussion among hydrologists and water managers in the region, but no comparative study has been performed to analyze the effects of different recharge distributions on groundwater simulations. This study investigates the importance of the distribution of aquifer recharge in simulating regional groundwater flow in basin-fill aquifers by calibrating a groundwater-flow model to four different recharge distributions, all with the same total amount of recharge. Similarities are seen in results from steady-state models for optimized hydraulic conductivity values, fit of simulated to observed hydraulic heads, and composite scaled sensitivities of conductivity parameter zones. Transient simulations with hypothetical storage properties and pumping rates produce similar capture rates and storage change results, but differences are noted in the rate of drawdown at some well locations owing to the differences in optimized hydraulic conductivity. Depending on whether the purpose of the groundwater model is to simulate changes in groundwater levels or changes in storage and capture, the distribution of aquifer recharge may or may not be of primary importance.
Large-scale volcano-ground ice interactions on Mars
Squyres, S. W.; Wilhelms, D.E.; Moosman, A.C.
1987-01-01
The process of volcano-ground ice interaction on Mars is investigated by thermodynamic calculations and observations of Viking Orbiter images. We develop a numerical model of volcano-ground ice interaction that includes heat transport by conduction, radiation from the surface, heat transfer to the atmosphere, and H2O phase changes in an ice-rich permafrost. We consider eruption of lava flows over permafrost, and intrusion of sills into permafrost. For eruption of lava over permafrost, most of the heat in the flow is lost by radiation and atmospheric effects. The amount of H2O liquid and vapor produced is small, and its removal would not be sufficient to cause collapse that would lower the surface of the lava flow below the surrounding terrain. For intrusion of a sill, most of the heat in the sill eventually goes into H2O phase changes, producing much larger amounts of water that could have profound geomorphic and geochemical effects. Approximate meltwater discharge rates are calculated for both extrusive and intrusive interactions. We examine two large regions of large-scale volcano-ground ice interactions. Near Aeolis Mensae, intrusion of a complex of dikes and sills into ice-rich ground has produced substantial melting, with mobilization and flow of material. This interaction probably also produced large quantities of palagonite tuff and breccia. Morphologic evidence for progressive fluidization implies that meltwater was stored beneath the surface for some time, and that most of the release of water and volcanic mudflow took place late in the interaction. Northeast of Hellas, several large channels emanate from the area near the volcano Hadriaca Patera. If genetically related to the volcanic activity, large collapse features at the sources of some channels must have originated due to heat from large buried magma bodies. A channel emerging directly from the base of Hadriaca Patera may have originated from release of heat from thick extruded material. Other small channels in the region results from heat released from surface lava flows. Inferred channel discharges may be compared to discharge rates calculated for lava-ground ice interactions. Such comparisons show that meltwater probably accumulated beneath the surface and then was released rapidly, with a discharge rate limited by soil permeability. Volcano-ground ice interaction has been a widespread and important geologic process on Mars, and may be the primary source of palagonites making up the ubiquitous Martian dust. ?? 1987.
Sanaka, Masaki; Yamamoto, Takatsugu; Ishii, Tarou; Kuyama, Yasushi
2004-01-01
In pharmacokinetics, the Wagner-Nelson (W-N) method can accurately estimate the rate of drug absorption from its urinary elimination rate. A stable isotope (13C) breath test attempts to estimate the rate of absorption of 13C, as an index of gastric emptying rate, from the rate of pulmonary elimination of 13CO2. The time-gastric emptying curve determined by the breath test is quite different from that determined by scintigraphy or ultrasonography. In this report, we have shown that the W-N method can adjust the difference. The W-N equation to estimate gastric emptying from breath data is as follows: the fractional cumulative amount of gastric contents emptied by time t = Abreath (t)/Abreath (infinity) + (1/0.65).d[Abreath (t)/Abreath (infinity) ]/dt, where Abreath (t) = the cumulative recovery of 13CO2 in breath by time t and Abreath ( infinity ) = the ultimate cumulative 13CO2 recovery. The emptying flow curve generated by ultrasonography was compared with that generated by the W-N method-adjusted breath test in 6 volunteers. The emptying curves by the W-N method were almost identical to those by ultrasound. The W-N method can generate an accurate emptying flow curve from 13CO2 data, and it can adjust the difference between ultrasonography and the breath test. Copyright 2004 S. Karger AG, Basel
NASA Astrophysics Data System (ADS)
ten Veldhuis, Marie-Claire; Schleiss, Marc
2017-04-01
Urban catchments are typically characterised by a more flashy nature of the hydrological response compared to natural catchments. Predicting flow changes associated with urbanisation is not straightforward, as they are influenced by interactions between impervious cover, basin size, drainage connectivity and stormwater management infrastructure. In this study, we present an alternative approach to statistical analysis of hydrological response variability and basin flashiness, based on the distribution of inter-amount times. We analyse inter-amount time distributions of high-resolution streamflow time series for 17 (semi-)urbanised basins in North Carolina, USA, ranging from 13 to 238 km2 in size. We show that in the inter-amount-time framework, sampling frequency is tuned to the local variability of the flow pattern, resulting in a different representation and weighting of high and low flow periods in the statistical distribution. This leads to important differences in the way the distribution quantiles, mean, coefficient of variation and skewness vary across scales and results in lower mean intermittency and improved scaling. Moreover, we show that inter-amount-time distributions can be used to detect regulation effects on flow patterns, identify critical sampling scales and characterise flashiness of hydrological response. The possibility to use both the classical approach and the inter-amount-time framework to identify minimum observable scales and analyse flow data opens up interesting areas for future research.
NASA Technical Reports Server (NTRS)
Lauer, J. L.; Vogel, P.
1984-01-01
Deposits laid down in patches on metal strips in a high pressure/high temperature fuel system simulator operated with aerated fuel at varying flow rates were analyzed by emission FTIR in terms of functional groups. Significant differences were found in the spectra and amounts of deposits derived from fuels to which small concentrations of oxygen-, nitrogen-, or sulfur-containing heterocyclics or metal naphthenates were added. The spectra of deposits generated on strips by heating fuels and air in a closed container were very different from those of the flowing fluid deposits. One such closed-container dodecane deposit on silver gave a strong surface-enhanced Raman spectrum.
Poulcharidis, Dimitrios; Belfor, Kimberley
2017-01-01
Membrane-compound exchange is vital for cell-to-cell communication, yet quantification of this process is difficult. Here we present a method using flow cytometry in combination with bioorthogonal and fluorescent labelling techniques to quantify the amount of exchange of cholesterol and sialylated compounds between cells. We demonstrate that direct cell–cell contact is the likely mechanism of sterol-exchange and show that by manipulating the contact time between cells using complementary coiled-coil peptides results in an enhanced exchange rate of membrane components between cells. PMID:28970937
Experimental investigation of turbine disk cavity aerodynamics and heat transfer
NASA Technical Reports Server (NTRS)
Daniels, W. A.; Johnson, B. V.
1993-01-01
An experimental investigation of turbine disk cavity aerodynamics and heat transfer was conducted to provide an experimental data base that can guide the aerodynamic and thermal design of turbine disks and blade attachments for flow conditions and geometries simulating those of the space shuttle main engine (SSME) turbopump drive turbines. Experiments were conducted to define the nature of the aerodynamics and heat transfer of the flow within the disk cavities and blade attachments of a large scale model simulating the SSME turbopump drive turbines. These experiments include flow between the main gas path and the disk cavities, flow within the disk cavities, and leakage flows through the blade attachments and labyrinth seals. Air was used to simulate the combustion products in the gas path. Air and carbon dioxide were used to simulate the coolants injected at three locations in the disk cavities. Trace amounts of carbon dioxide were used to determine the source of the gas at selected locations on the rotors, the cavity walls, and the interstage seal. The measurements on the rotor and stationary walls in the forward and aft cavities showed that the coolant effectiveness was 90 percent or greater when the coolant flow rate was greater than the local free disk entrainment flow rate and when room temperature air was used as both coolant and gas path fluid. When a coolant-to-gas-path density ratio of 1.51 was used in the aft cavity, the coolant effectiveness on the rotor was also 90 percent or greater at the aforementioned condition. However, the coolant concentration on the stationary wall was 60 to 80 percent at the aforementioned condition indicating a more rapid mixing of the coolant and flow through the rotor shank passages. This increased mixing rate was attributed to the destabilizing effects of the adverse density gradients.
NASA Astrophysics Data System (ADS)
Cornelisen, Christopher D.; Thomas, Florence I. M.
2004-08-01
Seagrasses rely on the uptake of dissolved inorganic nitrogen (DIN) from both sediment pore water and the water column for metabolic processes. Rates at which their leaves remove nutrients from the water column may be influenced by physiological factors, such as enzyme kinetics, and physical factors, including water flow and the presence of epiphytes on the leaf surface. While there is some evidence of the individual effects of these factors on uptake rates for individual plants, there is little information on the effects of these factors on seagrasses that are situated in their natural environment. In order to isolate the combined effects of water flow and epiphyte cover on uptake rates for Thalassia testudinum leaves while they were situated in a natural canopy we applied 15N-labeled ammonium and 15N-labeled nitrate in a series of field flume experiments. Hydrodynamic parameters related to thickness of diffusive boundary layers, including bottom shear stress and the rate of turbulent energy dissipation, were estimated from velocity profiles collected with an acoustic Doppler velocimeter. Rates of NH 4+ uptake for leaves with and without epiphyte cover were proportional to bottom shear stress and energy dissipation rate, while rates of NO 3- uptake were not. For epiphytes, rates of both NH 4+ and NO 3- uptake were dependent on hydrodynamic parameters. Epiphytes covering the leaf surface reduced rates of NH 4+ uptake for seagrass leaves by an amount proportional to the spatial area covered by the epiphytes (˜90%) and although epiphytes reduced NO 3- uptake rates, the amount was not proportional to the extent of epiphyte cover. Results suggest that the rate at which seagrass leaves removed ammonium was limited by the rate of delivery to the surface of the leaves and was greatly reduced due to blockage of active uptake sites by epiphytes. Conversely, rates of nitrate uptake for the seagrass leaves were limited by the rate at which the leaves could process nitrate rather than the rate of delivery. Our findings quantitatively demonstrate the potential impact of hydrodynamic regime and epiphyte cover on rates of DIN uptake by T. testudinum leaves and how the importance of these factors in affecting uptake rates can vary depending on the form of DIN being assimilated.
Carbon-dioxide flow measurement in geodynamically active area of West Bohemia
NASA Astrophysics Data System (ADS)
Vlcek, Josef; Fischer, Tomas; Heinicke, Jens
2016-04-01
Geodynamically active area of West Bohemia is interesting not only due to its earthquake swarms occurrence but also due to degassing flux of magmatic origin occurring in natural moffettes and mineral springs. While monitoring of earthquakes is done by a standard local seismic network, monitoring of amount of CO2 is at its initial stage. Despite lack of data, the 2014 earthquake swarm showed also very interesting increase in CO2 flow. This correlation with seismicity motivated us to develop robust and reliable methods of CO2 flow measurement, which would be sufficient to create denser monitoring network. Standard usage of gas-flowmeter for the purpose of gas flow measurement is dependent on the weather and device conditions, which makes the measurement instable in time and unreliable. Although gas-flowmeter is also accompanied with measurement of the gas pressure in the well to check flow rate value, reliability of this method is still low. This problematic behavior of the flow measurement was the reason to test new methods to measure CO2 amount - the first is based on measuring the density water with bubbles in the well by differential pressure gauge. The second one utilizes electric conductivity measurement to determine the density of bubbles in the water-gas mixture. Advantage of these methods is that their probes are directly in the well or moffette, where the concentration is measured. This approach is free of the influence of moving parts and assures the independence of measurements of environmental conditions. In this paper we show examples of obtained data series from selected sites and compare the trend of the curves, the mutual relations of the measured quantities and the influence of environmental conditions.
Flow and axial dispersion in a sinusoidal-walled tube: Effects of inertial and unsteady flows
NASA Astrophysics Data System (ADS)
Richmond, Marshall C.; Perkins, William A.; Scheibe, Timothy D.; Lambert, Adam; Wood, Brian D.
2013-12-01
In this work, we consider a sinusoidal-walled tube (a three-dimensional tube with sinusoidally-varying diameter) as a simplified conceptualization of flow in porous media. Direct numerical simulation using computational fluid dynamics (CFD) methods was used to compute velocity fields by solving the Navier-Stokes equations, and also to numerically solve the volume averaging closure problem, for a range of Reynolds numbers (Re) spanning the low-Re to inertial flow regimes, including one simulation at Re=449 for which unsteady flow was observed. The longitudinal dispersion observed for the flow was computed using a random walk particle tracking method, and this was compared to the longitudinal dispersion predicted from a volume-averaged macroscopic mass balance using the method of volume averaging; the results of the two methods were consistent. Our results are compared to experimental measurements of dispersion in porous media and to previous theoretical results for both the low-Re, Stokes flow regime and for values of Re representing the steady inertial regime. In the steady inertial regime, a power-law increase in the effective longitudinal dispersion (DL) with Re was found, and this is consistent with previous results. This rapid rate of increase is caused by trapping of solute in expansions due to flow separation (eddies). One unsteady (but non-turbulent) flow case (Re=449) was also examined. For this case, the rate of increase of DL with Re was smaller than that observed at lower Re. Velocity fluctuations in this regime lead to increased rates of solute mass transfer between the core flow and separated flow regions, thus diminishing the amount of tailing caused by solute trapping in eddies and thereby reducing longitudinal dispersion. The observed tailing was further explored through analysis of concentration skewness (third moment) and its assymptotic convergence to conventional advection-dispersion behavior (skewness = 0). The method of volume averaging was applied to develop a skewness model, and demonstrated that the skewness decreases as a function of inverse square root of time. Our particle tracking simulation results were shown to conform to this theoretical result in most of the cases considered.
Use of hollow fiber membrane filtration for the removal of DMSO from platelet concentrates.
Arnaud, F; Kapnik, E; Meryman, H T
2003-05-01
It has been hypothesized that, in addition to freezing injury, some damage to platelets may result from the cell packing that occurs during removal of the cryoprotectant. This study examined DMSO removal by fluid exchange across hollow-fiber (HF) filters as an alternative to centrifugation. The DMSO solution with or without cell suspension was passed once through the filter. The optimum exchange during unloading of DMSO was determined by varying the flow rates in the external and internal compartments of the HF filter. Initially, buffered solutions of a 5% DMSO solution in the absence of platelets were pumped into the fibers and exchanged against PBS. The residual DMSO was determined by osmometry. The exchange of DMSO across the membrane was flow dependent and also influenced by the chemical nature of the HF fibers. No protocol using a reasonable rate flow through the fibers removed more than 95% of the DMSO in a single pass. The optimum protocol was achieved with polysynthane fibers with an internal flow rate of approximately 20 mi/min and an external flow rate of 100 ml/min. Subsequently, frozen/thawed platelet concentrates in DMSO were washed using centrifugation and compared to the HF filtration method. Platelet quality was assayed by flow cytometry, cell count, morphology and osmotic stress test. Both filtration and centrifugal washing techniques resulted in comparable morphological scores and numbers of discoid cells. When agents reducing platelet activation were added, platelet quality was improved after washing by either technique. The lower platelet osmotic response with HF filtration than with centrifugation while using activation inhibitors was attributed to the remaining amount of the inhibitors. All other parameters tested were similar. The expression of CD62P was equivalent with both techniques, and centrifugation did not activate platelets more than filtration contrary to what was originally anticipated. In conclusion, platelet quality was comparable after washing by either technique but hollow fiber filtration does remove cryoprotectant more rapidly than does centrifugation.
Study of Low Flow Rate Ladle Bottom Gas Stirring Using Triaxial Vibration Signals
NASA Astrophysics Data System (ADS)
Yenus, Jaefer; Brooks, Geoffrey; Dunn, Michelle; Li, Zushu; Goodwin, Tim
2018-02-01
Secondary steelmaking plays a great role in enhancing the quality of the final steel product. The metal quality is a function of metal bath stirring in ladles. The metal bath is often stirred by an inert gas to achieve maximum compositional and thermal uniformity throughout the melt. Ladle operators often observe the top surface phenomena, such as level of meniscus disturbance, to evaluate the status of stirring. However, this type of monitoring has significant limitations in assessing the process accurately especially at low gas flow rate bubbling. The present study investigates stirring phenomena using ladle wall triaxial vibration at a low flow rate on a steel-made laboratory model and plant scale for the case of the vacuum tank degasser. Cold model and plant data were successfully modeled by partial least-squares regression to predict the amount of stirring. In the cold model, it was found that the combined vibration signal could predict the stirring power and recirculation speed effectively in specific frequency ranges. Plant trials also revealed that there is a high structure in each data set and in the same frequency ranges at the water model. In the case of industrial data, the degree of linear relationship was strong for data taken from a single heat.
Lee, Inn-Sook
2003-04-30
This quasi-experimental study was designed to investigate the effect of bedding control on the amount of house dust mite (HDM) allergens, asthma symptoms, and peak expiratory flow rate (PEFR) in asthmatics sensitive to HDMs. The subjects in the study were drawn from patients receiving treatment at the allergy clinics of three university-affiliated hospitals in Seoul. Forty-two patients without prior practice of the bedding control used in this study were selected. They commonly showed bronchial asthma caused by HDMs, and exhibited strong positive points (more than 3 points) in skin prick test (D. farinae, D. pteronyssinus), and positive response in both fluoro-allergosorbent test (FAST), and PC20 methacholine test. Of the subjects, alternatively, 22 were assigned to the experimental group and 20 to control group. Bedding control consisted of the use of outer cotton covers, boiling them for 10 minutes fortnightly, and disinfecting bedding by sunlight fortnightly. The experimental group was under bedding control for 4 weeks. The data were collected from October 2000 to January 2001. The results were as follows: 1. After bedding control, the total amount of HDM allergens decreased significantly in the experimental group. However there was no significant difference in the decrease of the amount of HDM allergens between the two groups. 2. Of the asthma symptoms, there was significant difference only in the decrease of the frequency of dyspnea, and in the increase of sleeping disturbance between the two groups after bedding control. 3. After bedding control, PEFR increased in the experimental group whereas it decreased in the control group. However, neither change was significant. The above findings indicate that bedding control improved several asthma symptoms in asthmatics sensitive to HDMs. Accordingly, we suggest that bedding control is adopted as a useful nursing intervention in the field.
NASA Astrophysics Data System (ADS)
Kang, Dong-Hyun; Kim, Kyongtae; Kim, Yong-Jun
2018-02-01
Microfluidic devices for plasma extraction are popular because they offer the advantage of smaller reagent consumption compared to conventional centrifugations. The plasma yield (volume percentage of plasma that can be extracted) is an important factor for diagnoses in microdevices with small reagent consumptions. However, recently designed microfluidic devices tend to have a low plasma yield because they have been optimized to improve the purity of extracted plasma. Thus, these devices require large amounts of reagents, and this complexity has eliminated the advantage of microfluidic devices that can operate with only small amounts of reagents. We therefore propose a continuous, real-time, blood plasma separation device, for plasma extraction rate enhancements. Moreover, a blood plasma separation device was designed to achieve improved plasma yields with high-purity efficiency. To obtain a high plasma yield, microstructures were placed on the bottom side of the channel to increase the concentration of blood cells. Plasma separation was then accomplished via microfluidic networks based on the Zweifach-Fung effect. The proposed device was fabricated based on the polydimethylsiloxane molding process using the SU-8 microfluidic channel for the fabrication of the mold and bottom structures. Human blood diluted in a phosphate buffered saline solution (25% hematocrit) was injected into the inlet of the device. The purity efficiencies were approximately equal to 96% with a maximum of 96.75% at a flow rate of 2 µl min-1, while the plasma yield was approximately 59% with a maximum of 59.92% at a flow rate of 4 µl min-1. Compared to results obtained using other devices, our proposed device could obtain comparable or higher plasma purity and a high plasma yield.
The supernova-regulated ISM. III. Generation of vorticity, helicity, and mean flows
NASA Astrophysics Data System (ADS)
Käpylä, M. J.; Gent, F. A.; Väisälä, M. S.; Sarson, G. R.
2018-03-01
Context. The forcing of interstellar turbulence, driven mainly by supernova (SN) explosions, is irrotational in nature, but the development of significant amounts of vorticity and helicity, accompanied by large-scale dynamo action, has been reported. Aim. Several earlier investigations examined vorticity production in simpler systems; here all the relevant processes can be considered simultaneously. We also investigate the mechanisms for the generation of net helicity and large-scale flow in the system. Methods: We use a three-dimensional, stratified, rotating and shearing local simulation domain of the size 1 × 1 × 2 kpc3, forced with SN explosions occurring at a rate typical of the solar neighbourhood in the Milky Way. In addition to the nominal simulation run with realistic Milky Way parameters, we vary the rotation and shear rates, but keep the absolute value of their ratio fixed. Reversing the sign of shear vs. rotation allows us to separate the rotation- and shear-generated contributions. Results: As in earlier studies, we find the generation of significant amounts of vorticity, the rotational flow comprising on average 65% of the total flow. The vorticity production can be related to the baroclinicity of the flow, especially in the regions of hot, dilute clustered supernova bubbles. In these regions, the vortex stretching acts as a sink of vorticity. In denser, compressed regions, the vortex stretching amplifies vorticity, but remains sub-dominant to baroclinicity. The net helicities produced by rotation and shear are of opposite signs for physically motivated rotation laws, with the solar neighbourhood parameters resulting in the near cancellation of the total net helicity. We also find the excitation of oscillatory mean flows, the strength and oscillation period of which depend on the Coriolis and shear parameters; we interpret these as signatures of the anisotropic-kinetic-α (AKA) effect. We use the method of moments to fit for the turbulent transport coefficients, and find αAKA values of the order 3-5 km s-1. Conclusions: Even in a weakly rotationally and shear-influenced system, small-scale anisotropies can lead to significant effects at large scales. Here we report on two consequences of such effects, namely on the generation of net helicity and on the emergence of large-scale flows by the AKA effect, the latter detected for the first time in a direct numerical simulation of a realistic astrophysical system.
The influence of wetting dynamics on the residual air distribution
NASA Astrophysics Data System (ADS)
Sacha, J.; Snehota, M.; Trtik, P.; Vontobel, P.
2016-12-01
The amount and distribution of the residual air during the infiltration into a porous soil system has a strong influence on the infiltration rate. Concurrently, the amount of residual air is dependent on the wetting dynamics. In the presented study, two experiments were conducted on the same sample. The first experiment was performed under the constant water level condition (CWL) and the second under the constant water flux condition (CWF) at the top of the sample. The sample that composed of coarse and medium coarse fractions of sand and fine porous ceramics was packed into the quartz glass columns of the inner diameter of 29 mm. The coarse sand represented a highly conductive region connected from the top to the bottom of the sample with the exception of three low (2-3 mm) separation layers made up of the medium coarse sand. Three discs of fine ceramic formed slow flow regions. Infiltration experiments were monitored by neutron radiography on two different beamlines to produce two-dimensional (2D) projections. The CWL experiment was monitored by NEUTRA station with an acquisition time of 16 seconds per projection and the CWF experiment was visualized at BOA station with an acquisition time of 0.25 seconds per projection. Both stations are located at the Paul Scherrer Institut, Switzerland. The acquired radiograms of the dry sample were subtracted from all subsequent radiograms to determine the water thickness in projections. From series of corrected radiograms taken at the different angles three-dimensional (3D) image was reconstructed for steady state part of the experiment CWL and for entire experiment CWF. Then the series of 3D images mapped the wetting of the porous system over the corresponding phase of infiltration process. The results showed a faster steady state infiltration rate during the CWL. In this case, the air was mostly pushed out from the sample by moving wetting front. On the contrary, during the CWF the water infiltrated into the fine ceramics first and then into the medium coarse sand attracted by stronger capillary forces in comparison to the coarse sand. Due to this effect a significant amount of air was trapped in preferential pathways, and consequently blocking the water flow. The presence of medium coarse sand regions had a crucial impact on the water flow and amount of air trapping.
On the POD based reduced order modeling of high Reynolds flows
NASA Astrophysics Data System (ADS)
Behzad, Fariduddin; Helenbrook, Brian; Ahmadi, Goodarz
2012-11-01
Reduced-order modeling (ROM) of a high Reynolds fluid flow using the proper orthogonal decomposition (POD) was studied. Particular attention was given to incompressible, unsteady flow over a two-dimensional NACA0015 airfoil. The Reynolds number is 105 and the angle of attacked of the airfoil is 12°. For DNS solution, hp-finite element method is employed to drive flow samples from which the POD modes are extracted. Particular attention is paid on two issues. First, the stability of POD-ROM resimulation of the turbulent flow is studied. High Reynolds flow contains a lot of fluctuating modes. So, to reach a certain amount of error, more POD modes are needed and the effect of truncation of POD modes is more important. Second, the role of convergence rate on the results of POD. Due to complexity of the flow, convergence of the governing equations is more difficult and the influences of weak convergence appear in the results of POD-ROM. For each issue, the capability of the POD-ROM is assessed in terms of predictions quality of times upon which the POD model was derived. The results are compared with DNS solution and the accuracy and efficiency of different cases are evaluated.
The Geomorphic Role of Large Woody Debris in River Avulsions
NASA Astrophysics Data System (ADS)
Stout, J. C.; Grove, J. R.; Rutherfurd, I.; Marren, P.
2014-12-01
The avulsion or abandonment of a river channel in favor of a new course on the floodplain is integral to the development and maintenance of anabranching planforms. Avulsions tend to occur on rivers where the rate of vertical aggradation outpaces lateral migration. In fine cohesive floodplain sediments, avulsions evolve through five stages dependent on the amount of flow and sediment being captured by the new channel. There is limited data available to allow the prediction of autogenic and allogenic controls on: the time over which an avulsion is active; its likely location; the frequency of occurrence; and the length of the interavulsion period. The delivery of wood to the river channel is an autogenic process which has received much attention over the last three decades. Surprisingly it has not previously been considered in anabranch avulsions, apart from where log-jams entirely block channels. The presence of large woody debris in the channel acts as a roughness element, trapping, and impeding the movement of sediments and deflecting flow onto the floodplain. We hypothesize that the delivery rates of wood to the channel, and its subsequent configuration (i.e. dimension, amount, volume, spatial arrangement and blockage ratio), alters flow and sediment routing through the channel. These changes directly influence the stages of avulsion development. To test this conceptual model we have used eleven floodplain cores to reconstruct the timing of a Holocene avulsion. The morphology of the channel in each evolutionary stage was used to estimate the relative role of wood as a roughness element. This was done by coupling a mass balance wood delivery model, run in a Monte Carlo simulation, to the geomorphic processes of each evolutionary stage of the avulsion. Our results allow us to quantify the importance of in-channel wood during each stage of the avulsion. These data highlight that there are critical points in the evolution of anabranching channels when large wood influences the avulsion rate and location.
Field and flume investigations of the effects of logjams and woody debris on streambed morphology
NASA Astrophysics Data System (ADS)
Leung, V.; Montgomery, D. R.; McHenry, M. L.
2014-12-01
Interactions among wood debris, fluid flow and sediment transport in rivers are first-order controls on channel morphodynamics, affecting streambed morphology, sediment transport, sediment storage and aquatic habitat. Woody debris increases the hydraulic and topographic complexity in rivers, leading to a greater diversity of aquatic habitats and an increase in the number of large pools that are important fish habitat and breeding grounds. In the past decade, engineered logjams have become an increasingly used tool in river management for simultaneously decreasing the rate of riverbank migration and improving aquatic habitat. Sediment deposits around woody debris build up riverbanks and counteract bank migration caused by erosion. Previous experiments on flow visualization around model woody debris suggest the amount of sediment scour and deposition are primarily related to the presence of roots and the obstructional area of the woody debris. We present the results of fieldwork and sediment transport experiments of streambed morphology around stationary woody debris. Field surveys on the Hoh River and the Elwha River, WA, measure the local streambed morphology around logjams and individual pieces of woody debris. We quantified the amount of local scour and dam-removal related fine sediment deposition around natural and engineered logjams of varying sizes and construction styles, located in different geomorphic settings. We also quantified the amount of local scour around individual pieces of woody debris of varying sizes, geometries and orientations relative to flow. The flume experiments tested the effects of root geometry and log orientation of individual stationary trees on streambed morphology. The flume contained a deformable sediment bed of medium sand. We find that: 1) the presence of roots on woody debris leads to greater areas of both sediment scour and deposition; and 2) the amount of sediment scour and deposition are related to the wood debris cross-sectional area, oriented orthogonal to flow. A better understanding of the underlying sediment physics and hydraulics around naturally occurring woody debris in rivers can provide guidance and criteria for use in river restoration and engineering as well as scientific insights into a complex interdisciplinary problem.
NASA Astrophysics Data System (ADS)
Hou, Huirang; Zheng, Dandan; Nie, Laixiao
2015-04-01
For gas ultrasonic flowmeters, the signals received by ultrasonic sensors are susceptible to noise interference. If signals are mingled with noise, a large error in flow measurement can be caused by triggering mistakenly using the traditional double-threshold method. To solve this problem, genetic-ant colony optimization (GACO) based on the ultrasonic pulse received signal model is proposed. Furthermore, in consideration of the real-time performance of the flow measurement system, the improvement of processing only the first three cycles of the received signals rather than the whole signal is proposed. Simulation results show that the GACO algorithm has the best estimation accuracy and ant-noise ability compared with the genetic algorithm, ant colony optimization, double-threshold and enveloped zero-crossing. Local convergence doesn’t appear with the GACO algorithm until -10 dB. For the GACO algorithm, the converging accuracy and converging speed and the amount of computation are further improved when using the first three cycles (called GACO-3cycles). Experimental results involving actual received signals show that the accuracy of single-gas ultrasonic flow rate measurement can reach 0.5% with GACO-3 cycles, which is better than with the double-threshold method.
Unsteady penetration of a target by a liquid jet
Uth, Tobias; Deshpande, Vikram S.
2013-01-01
It is widely acknowledged that ceramic armor experiences an unsteady penetration response: an impacting projectile may erode on the surface of a ceramic target without substantial penetration for a significant amount of time and then suddenly start to penetrate the target. Although known for more than four decades, this phenomenon, commonly referred to as dwell, remains largely unexplained. Here, we use scaled analog experiments with a low-speed water jet and a soft, translucent target material to investigate dwell. The transient target response, in terms of depth of penetration and impact force, is captured using a high-speed camera in combination with a piezoelectric force sensor. We observe the phenomenon of dwell using a soft (noncracking) target material. The results show that the penetration rate increases when the flow of the impacting water jet is reversed due to the deformation of the jet–target interface––this reversal is also associated with an increase in the force exerted by the jet on the target. Creep penetration experiments with a constant indentation force did not show an increase in the penetration rate, confirming that flow reversal is the cause of the unsteady penetration rate. Our results suggest that dwell can occur in a ductile noncracking target due to flow reversal. This phenomenon of flow reversal is rather widespread and present in a wide range of impact situations, including water-jet cutting, needleless injection, and deposit removal via a fluid jet. PMID:24277818
Modeling of Turbulent Swirling Flows
NASA Technical Reports Server (NTRS)
Shih, Tsan-Hsing; Zhu, Jiang; Liou, William; Chen, Kuo-Huey; Liu, Nan-Suey; Lumley, John L.
1997-01-01
Aircraft engine combustors generally involve turbulent swirling flows in order to enhance fuel-air mixing and flame stabilization. It has long been recognized that eddy viscosity turbulence models are unable to appropriately model swirling flows. Therefore, it has been suggested that, for the modeling of these flows, a second order closure scheme should be considered because of its ability in the modeling of rotational and curvature effects. However, this scheme will require solution of many complicated second moment transport equations (six Reynolds stresses plus other scalar fluxes and variances), which is a difficult task for any CFD implementations. Also, this scheme will require a large amount of computer resources for a general combustor swirling flow. This report is devoted to the development of a cubic Reynolds stress-strain model for turbulent swirling flows, and was inspired by the work of Launder's group at UMIST. Using this type of model, one only needs to solve two turbulence equations, one for the turbulent kinetic energy k and the other for the dissipation rate epsilon. The cubic model developed in this report is based on a general Reynolds stress-strain relationship. Two flows have been chosen for model evaluation. One is a fully developed rotating pipe flow, and the other is a more complex flow with swirl and recirculation.
Sakota, Daisuke; Kosaka, Ryo; Nishida, Masahiro; Maruyama, Osamu
2016-09-01
The aggregability of red blood cell (RBCs) is associated with the contribution of plasma proteins, such as fibrinogen and lipoproteids, to blood-clotting. Hence, we hypothesized that RBC aggregability reflects the blood-clotting reaction. A noninvasive optical monitoring method to measure RBC aggregability for the assessment of blood-clotting stage during mechanical circulatory support was developed. An in vitro thrombogenic test was conducted with a rotary blood pump using heparinized fresh porcine blood. Near-infrared laser light at a wavelength of 785 nm was guided by an optical fiber. The fibers for detecting incident, forward-, and backward-scattered light were fixed on the circuit tubing with an inner diameter of 1/4 inch. Because there is substantial RBC aggregation at low shear flow rates, a pulsatile flow was generated by controlling the pump rotational speed. The flow rate was changed from 0 to 8.5 L/min at a period of 40 s. The intensities of forward- and backward-scattered light changed dramatically when the flow stopped. The aggregability was evaluated by the increase ratio of the transmitted light intensity from the flow stopping in the low-flow condition. The experiment started when the anticoagulation was stopped by the addition of protamine into the circulating blood. Reduction in RBC aggregability was associated with a decrease in the amount of fibrinogen and the number of platelets. Continuous, noninvasive monitoring of thrombosis risk is possible using optical measurements combining pulsatile flow control of a rotary blood pump. RBC aggregometry is a potential label-free method for evaluating blood-clotting risk.
Permeability of oral tissues to blood-borne coxsackievirus B-1.
Madonia, J V; Bahn, A N
1967-03-01
The ability of coxsackievirus B-1 to pass the barriers of the circulatory system into whole saliva has been shown previously. In this investigation, the major salivary glands and the oral mucosa were studied, and their role as participants in the excretion of coxsackievirus B-1 during viremia was evaluated. The effect of the salivary-gland stimulant pilocarpine nitrate on both the salivary flow rate and the recovery of virus during viremia was determined. A comparison was made between the amount of virus recovered from whole saliva during viremia in animals deficient in one or both of the major salivary-gland pairs and animals with a complete complement of salivary glands. The salivary glands in other animals were cannulated, and pure glandular secretions were collected during viremia and assayed for the presence of virus The amount of virus passing from the capillaries of the oral mucosa to the surface was also determined to evaluate this route as a possible site for the excretion of virus into saliva during viremia. The major salivary glands did not excrete appreciable quantities of virus during viremia. The submaxillary-gland secretions did not contain virus, and the parotid-gland secretions showed virus only at extremely high blood virus levels. Either removal of the major salivary glands or decreased salivary flow rates increased the concentration of virus in whole saliva. This observation suggested that the production of saliva by the major salivary glands tends to dilute the virus in the oral cavity. A 0.88-cm(2) sample of the oral mucosa excreted significantly large amounts of virus during viremia and suggested that the passage of virus through the oral mucosa was the major route for the excretion of virus into saliva during viremia.
Simultaneous Extraction of Lithium and Hydrogen from Seawater
2011-04-26
chromatography . Anions were analyzed by Anion Ion Chromatography (Instrument Dionex ICS-1500, Column Dionex AS9-HC; AG9-HC Guard, eluent: 9.00 mM Na2CO3, flow...rate: 1.25 mL/min, and sample loop was 25 μL). Cations were analyzed by Cation Ion Chromatography (Instrument Dionex DX-500, Cation Column Dionex ...the amount was measured volumetrically. Ion chromatography : Ions in seawater diffused from/to the anode and cathode were determined by ion
Tsui, L.; Krapac, I.G.; Roy, W.R.
2007-01-01
Nitrate is a major agricultural pollutant found in drainage waters. Immature yard-waste compost was selected as a filter media to study its feasibility for removing nitrate from drainage water. Different operation parameters were tested to examine the denitrification efficiency, including the amounts of compost packed in columns, the flow rate, and the compost storage periods. The experimental results suggested that hydraulic retention time was the major factor to determine the extent of nitrate removal, although the amount of compost packed could also contribute to the nitrate removal efficiency. The effluent nitrate concentration increased as the flow rate decreased, and the compost column reduced nitrate concentrations from 20 mg/L to less than 5 mg/L within 1.5 h. The solution pH increased at the onset of experiment because of denitrification, but stabilized at a pH of about 7.8, suggesting that the compost had a buffering capacity to maintain a suitable pH for denitrification. Storing compost under air-dried conditions may diminish the extent nitrate removed initially, but the effects were not apparent after longer applications. It appeared that immature yard-waste compost may be a suitable material to remove nitrate from tile drainage water because of its relatively large organic carbon content, high microbial activity, and buffering capacity. ?? 2006 Elsevier B.V. All rights reserved.
Parallel generation of uniform fine droplets at hundreds of kilohertz in a flow-focusing module.
Bardin, David; Kendall, Michael R; Dayton, Paul A; Lee, Abraham P
2013-01-01
Droplet-based microfluidic systems enable a variety of biomedical applications from point-of-care diagnostics with third world implications, to targeted therapeutics alongside medical ultrasound, to molecular screening and genetic testing. Though these systems maintain the key advantage of precise control of the size and composition of the droplet as compared to conventional methods of production, the low rates at which droplets are produced limits translation beyond the laboratory setting. As well, previous attempts to scale up shear-based microfluidic systems focused on increasing the volumetric throughput and formed large droplets, negating many practical applications of emulsions such as site-specific therapeutics. We present the operation of a parallel module with eight flow-focusing orifices in the dripping regime of droplet formation for the generation of uniform fine droplets at rates in the hundreds of kilohertz. Elevating the capillary number to access dripping, generation of monodisperse droplets of liquid perfluoropentane in the parallel module exceeded 3.69 × 10(5) droplets per second, or 1.33 × 10(9) droplets per hour, at a mean diameter of 9.8 μm. Our microfluidic method offers a novel means to amass uniform fine droplets in practical amounts, for instance, to satisfy clinical needs, with the potential for modification to form massive amounts of more complex droplets.
Mass Transfer And Hydraulic Testing Of The V-05 And V-10 Contactors With The Next Generation Solvent
DOE Office of Scientific and Technical Information (OSTI.GOV)
Herman, D. T.; Duignan, M. R.; Williams, M. R.
The Modular Caustic Side Solvent Extraction (CSSX) Unit (MCU) facility is actively pursuing the transition from the current BOBCalixC6 based solvent to the Next Generation Solvent (NGS)-MCU solvent. To support this integration of NGS into the MCU facilities, Savannah River Remediation (SRR) requested that Savannah River National Laboratory (SRNL) perform testing of a blend of the NGS (MaxCalix based solvent) with the current solvent (BOBCalixC6 based solvent) for the removal of cesium (Cs) from the liquid salt waste stream. This testing differs from prior testing by utilizing a blend of BOBCalixC6 based solvent and the NGS with the full (0.05more » M) concentration of the MaxCalix as well as a new suppressor, tris(3,7dimethyloctyl) guanidine. Single stage tests were conducted using the full size V-05 and V-10 centrifugal contactors installed at SRNL. These tests were designed to determine the mass transfer and hydraulic characteristics with the NGS solvent blended with the projected heel of the BOBCalixC6 based solvent that will exist in MCU at time of transition. The test program evaluated the amount of organic carryover and the droplet size of the organic carryover phases using several analytical methods. Stage efficiency and mass distribution ratios were determined by measuring Cs concentration in the aqueous and organic phases during single contactor testing. The nominal cesium distribution ratio, D(Cs) measured for extraction ranged from 37-60. The data showed greater than 96% stage efficiency for extraction. No significant differences were noted for operations at 4, 8 or 12 gpm aqueous salt simulant feed flow rates. The first scrub test (contact with weak caustic solution) yielded average scrub D(Cs) values of 3.3 to 5.2 and the second scrub test produced an average value of 1.8 to 2.3. For stripping behavior, the “first stage” D Cs) values ranged from 0.04 to 0.08. The efficiency of the low flow (0.27 gpm aqueous) was calculated to be 82.7%. The Spreadsheet Algorithm for Stagewise Solvent Extraction (SASSE) predicted equivalent DF for MCU from this testing is greater than 3,500 assuming 95% efficiency during extraction and 80% efficiency during scrub and strip. Hydraulically, the system performed very well in all tests. Target flows were easily obtained and stable throughout testing. Though some issues were encountered with plugging in the coalescer, they were not related to the solvent. No hydraulic upsets due to the solvent were experienced during any of the tests conducted. The first extraction coalescer element used in testing developed high pressure drop that made it difficult to maintain the target flow rates. Analysis showed an accumulation of sodium aluminosilicate solids. The coalescer was replaced with one from the same manufacturer’s lot and pressure drop was no longer an issue. Concentrations of Isopar™ L and Modifier were measured using semi-volatile organic analysis (SVOA) and high performance liquid chromatography (HPLC) to determine the amount of solvent carryover. For low-flow (0.27 gpm aqueous) conditions in stripping, SVOA measured the Isopar™ L post-contactor concentration to be 25 mg/L, HPLC measured 39 mg/L of Modifier. For moderate-flow (0.54 gpm aqueous) conditions, SVOA measured the Isopar™ L postcontactor to be ~69 mg/L, while the HPLC measured 56 mg/L for Modifier. For high-flow (0.8 gpm aqueous) conditions, SVOA measured the Isopar™ L post-contactor to be 39 mg/L. The post-coalescer (pre-decanter) measurements by SVOA for Isopar™ L were all less than the analysis detection limit of 10 mg/L. The HPLC measured 18, 22 and 20 mg/L Modifier for the low, medium, and high-low rates respectively. In extraction, the quantity of pre-coalescer Isopar™ L carryover measured by SVOA was ~280-410 mg/L at low flow (4 gpm aqueous), ~400-450 mg/L at moderate flow (8 gpm aqueous), and ~480 mg/L at high flow (12 gpm aqueous). The amount of post coalescer (pre-decanter) Isopar™ L carryover measured by SVOA was less than 45 mg/L for all flow rates. HPLC results for Modifier were 182, 217 and 222 mg/L for the post-contactor low, medium and high flow rates. The post-coalescer (pre-decanter) samples were measured to contain 12, 10 and 22 mg/L Modifier for the low, medium, and high flow rates. The carryover results and droplet size measurements were used to determine the decanter performance utilizing the decanter model developed by the ARES Corporation. Results show for the targeted salt flow rate of approximately 8 gpm, that over 93% of the solvent carryover from stripping is predicted to be recovered and over 96% solvent carryover from extraction is predicted to be recovered. This translates to a predicted solvent carryover of <3 ppm from stripping and <20 ppm solvent carryover from extraction. This projected performance at MCU is expected to be well within the operating limits and the historical performance for the baseline BOBCalixC6 based solvent. Droplet-size data obtained by MicroTrac™ S3400 analyzer consistently shows that the droplet size post-oalescer is significantly greater than the post-contactor or pre-coalescer samples. Increased flow rates did not show a consistent impact to the droplet size results. For the extraction testing, droplet size analysis showed that the post-contactor and pre-coalescer samples were essentially the same. The mean droplet sizes post-coalescer were less than the mean droplet sizes pre-coalescer with a very slight upward trend in the mean droplet size as the flow rate was increased. This result is probably due to the method of sampling. The larger post-coalescer drops immediately rise to the surface after leaving the coalescer element. The downstream sampling point was horizontally in-line with the element and therefore would only capture those organic droplets well mixed in the flowing aqueous stream.« less
Vetsch, Jolanda Rita; Betts, Duncan Colin; Müller, Ralph; Hofmann, Sandra
2017-01-01
Mechanical loading plays a major role in bone remodeling and fracture healing. Mimicking the concept of mechanical loading of bone has been widely studied in bone tissue engineering by perfusion cultures. Nevertheless, there is still debate regarding the in-vitro mechanical stimulation regime. This study aims at investigating the effect of two different flow rates (vlow = 0.001m/s and vhigh = 0.061m/s) on the growth of mineralized tissue produced by human mesenchymal stromal cells cultured on 3-D silk fibroin scaffolds. The flow rates applied were chosen to mimic the mechanical environment during early fracture healing or during bone remodeling, respectively. Scaffolds cultured under static conditions served as a control. Time-lapsed micro-computed tomography showed that mineralized extracellular matrix formation was completely inhibited at vlow compared to vhigh and the static group. Biochemical assays and histology confirmed these results and showed enhanced osteogenic differentiation at vhigh whereas the amount of DNA was increased at vlow. The biological response at vlow might correspond to the early stage of fracture healing, where cell proliferation and matrix production is prominent. Visual mapping of shear stresses, simulated by computational fluid dynamics, to 3-D micro-computed tomography data revealed that shear stresses up to 0.39mPa induced a higher DNA amount and shear stresses between 0.55mPa and 24mPa induced osteogenic differentiation. This study demonstrates the feasibility to drive cell behavior of human mesenchymal stromal cells by the flow velocity applied in agreement with mechanical loading mimicking early fracture healing (vlow) or bone remodeling (vhigh). These results can be used in the future to tightly control the behavior of human mesenchymal stromal cells towards proliferation or differentiation. Additionally, the combination of experiment and simulation presented is a strong tool to link biological responses to mechanical stimulation and can be applied to various in-vitro cultures to improve the understanding of the cause-effect relationship of mechanical loading.
OPTIMIZATION ON MATERIAL FLOW OF NON-METALIC MINERAL MATERIALS TOWARDS SUSTAINABLE SOCIETY
NASA Astrophysics Data System (ADS)
Sakamoto, Kouji; Nakayama, Hirofumi; Shimaoka, Takayuki; Hasegawa, Ryoji; Osako, Masahiro
Since non-metarilc mineral waste such as concrete mass, asphalt concrete mass, sand, slag and coal ash occupies 36% of total amount of waste generation and 26% of total amount of final disposal, it has significant influence on material flow of our country. Although the amount of non-metaril mineral wastes produced is expected to increase in the near future, demand of their application for recycled construction materials will decrease due to the reduction of public construction works and less use of materials in construction. The aim is to reduce environmental load caused by recycling and disposal of non metallic mineral materials, this study was conducted to evaluate the measurement for the reduction of environmental load like landfill amount and CO2 emission amount by controlling material flow of non metallic mineral materials in the year 2030 by linear programming.
NASA Technical Reports Server (NTRS)
Yang, R. J.; Weinberg, B. C.; Shamroth, S. J.; Mcdonald, H.
1985-01-01
The application of the time-dependent ensemble-averaged Navier-Stokes equations to transonic turbine cascade flow fields was examined. In particular, efforts focused on an assessment of the procedure in conjunction with a suitable turbulence model to calculate steady turbine flow fields using an O-type coordinate system. Three cascade configurations were considered. Comparisons were made between the predicted and measured surface pressures and heat transfer distributions wherever available. In general, the pressure predictions were in good agreement with the data. Heat transfer calculations also showed good agreement when an empirical transition model was used. However, further work in the development of laminar-turbulent transitional models is indicated. The calculations showed most of the known features associated with turbine cascade flow fields. These results indicate the ability of the Navier-Stokes analysis to predict, in reasonable amounts of computation time, the surface pressure distribution, heat transfer rates, and viscous flow development for turbine cascades operating at realistic conditions.
Holocinematographic velocimeter for measuring time-dependent, three-dimensional flows
NASA Technical Reports Server (NTRS)
Beeler, George B.; Weinstein, Leonard M.
1987-01-01
Two simulatneous, orthogonal-axis holographic movies are made of tracer particles in a low-speed water tunnel to determine the time-dependent, three-dimensional velocity field. This instrument is called a Holocinematographic Velocimeter (HCV). The holographic movies are reduced to the velocity field with an automatic data reduction system. This permits the reduction of large numbers of holograms (time steps) in a reasonable amount of time. The current version of the HCV, built for proof-of-concept tests, uses low-frame rate holographic cameras and a prototype of a new type of water tunnel. This water tunnel is a unique low-disturbance facility which has minimal wall effects on the flow. This paper presents the first flow field examined by the HCV, the two-dimensional von Karman vortex street downstream of an unswept circular cylinder. Key factors in the HCV are flow speed, spatial and temporal resolution required, measurement volume, film transport speed, and laser pulse length. The interactions between these factors are discussed.
Increasing Operational Stability in Low NO
NASA Astrophysics Data System (ADS)
Levy, Yeshayahou; Erenburg, Vladimir; Sherbaum, Valery; Ovcharenko, Vitali; Rosentsvit, Leonid; Chudnovsky, Boris; Herszage, Amiel; Talanker, Alexander
2012-03-01
Lean combustion is a method in which combustion takes place under low equivalence ratio and relatively low combustion temperatures. As such, it has the potential to lower the effect of the relatively high activation energy nitrogen-oxygen reactions which are responsible for substantial NO
NASA Technical Reports Server (NTRS)
Wang, Qun-Zhen; Cash, Steve (Technical Monitor)
2002-01-01
It is very important to accurately predict the gas pressure, gas and solid temperature, as well as the amount of O-ring erosion inside the space shuttle Reusable Solid Rocket Motor (RSRM) joints in the event of a leak path. The scenarios considered are typically hot combustion gas rapid pressurization events of small volumes through narrow and restricted flow paths. The ideal method for this prediction is a transient three-dimensional computational fluid dynamics (CFD) simulation with a computational domain including both combustion gas and surrounding solid regions. However, this has not yet been demonstrated to be economical for this application due to the enormous amount of CPU time and memory resulting from the relatively long fill time as well as the large pressure and temperature rising rate. Consequently, all CFD applications in RSRM joints so far are steady-state simulations with solid regions being excluded from the computational domain by assuming either a constant wall temperature or no heat transfer between the hot combustion gas and cool solid walls.
Chin, Jefferson; Wood, Elizabeth; Peters, Grace S; Drexler, Dieter M
2016-02-01
In the early stages of drug discovery, high-throughput screening (HTS) of compound libraries against pharmaceutical targets is a common method to identify potential lead molecules. For these HTS campaigns to be efficient and successful, continuous quality control of the compound collection is necessary and crucial. However, the large number of compound samples and the limited sample amount pose unique challenges. Presented here is a proof-of-concept study for a novel process flow for the quality control screening of small-molecule compound libraries that consumes only minimal amounts of samples and affords compound-specific molecular data. This process employs an acoustic sample deposition (ASD) technique for the offline sample preparation by depositing nanoliter volumes in an array format onto microscope glass slides followed by matrix-assisted laser desorption/ionization mass spectrometric (MALDI-MS) analysis. An initial study of a 384-compound array employing the ASD-MALDI-MS workflow resulted in a 75% first-pass positive identification rate with an analysis time of <1 s per sample. © 2015 Society for Laboratory Automation and Screening.
Rygg, Alex D.; Cox, Jonathan P. L.; Abel, Richard; Webb, Andrew G.; Smith, Nadine B.; Craven, Brent A.
2013-01-01
The hammerhead shark possesses a unique head morphology that is thought to facilitate enhanced olfactory performance. The olfactory chambers, located at the distal ends of the cephalofoil, contain numerous lamellae that increase the surface area for olfaction. Functionally, for the shark to detect chemical stimuli, water-borne odors must reach the olfactory sensory epithelium that lines these lamellae. Thus, odorant transport from the aquatic environment to the sensory epithelium is the first critical step in olfaction. Here we investigate the hydrodynamics of olfaction in Sphyrna tudes based on an anatomically-accurate reconstruction of the head and olfactory chamber from high-resolution micro-CT and MRI scans of a cadaver specimen. Computational fluid dynamics simulations of water flow in the reconstructed model reveal the external and internal hydrodynamics of olfaction during swimming. Computed external flow patterns elucidate the occurrence of flow phenomena that result in high and low pressures at the incurrent and excurrent nostrils, respectively, which induces flow through the olfactory chamber. The major (prenarial) nasal groove along the cephalofoil is shown to facilitate sampling of a large spatial extent (i.e., an extended hydrodynamic “reach”) by directing oncoming flow towards the incurrent nostril. Further, both the major and minor nasal grooves redirect some flow away from the incurrent nostril, thereby limiting the amount of fluid that enters the olfactory chamber. Internal hydrodynamic flow patterns are also revealed, where we show that flow rates within the sensory channels between olfactory lamellae are passively regulated by the apical gap, which functions as a partial bypass for flow in the olfactory chamber. Consequently, the hammerhead shark appears to utilize external (major and minor nasal grooves) and internal (apical gap) flow regulation mechanisms to limit water flow between the olfactory lamellae, thus protecting these delicate structures from otherwise high flow rates incurred by sampling a larger area. PMID:23555780
May, Robert [Virginia Beach, VA
2008-03-11
A method for determining the mobility of hydrogen as a function of temperature in superconducting niobium cavities comprising: 1) heating a cavity under test to remove free hydrogen; 2) introducing hydrogen-3 gas into the cavity; 3) cooling the cavity to allow absorption of hydrogen-3; and 4) measuring the amount of hydrogen-3 by: a) cooling the cavity to about 4.degree. K while flowing a known and regulated amount of inert carrier gas such as argon or helium into the cavity; b) allowing the cavity to warm at a stable rate from 4.degree. K to room temperature as it leaves the chamber; and c) directing the exit gas to an ion chamber radiation detector.
Viscous Flow Causes Weakening in Calcite Nanogouges Sheared at Seismic Velocity
NASA Astrophysics Data System (ADS)
Pozzi, G.; De Paola, N.; Nielsen, S. B.; Holdsworth, R.
2016-12-01
Recent experimental studies have suggested that the activation of diffusion creep at high temperatures (T ≥ 800 °C) and strain rates in nanograin aggregates can weaken faults and facilitate earthquake propagation. However, the frictional properties of nanoscale aggregates at high strain rates and T are still poorly investigated and, in particular, their flow laws at these extreme conditions are poorly constrained due to lack of knowledge about the evolution of grain size and strain localization during seismic slip. Experiments performed in a rotary shear apparatus on micro- and nano-metric calcite gouges (d=63-90 µm and d 200nm, respectively) at seismic (up to 1.4 m/s) and subseismic (<10 cm/s) velocities, arrested at different amounts of slip, show that: (i) onset of dynamic weakening in the nanogouge is faster, with a significantly reduced initial phase of slip hardening, (ii) dynamic weakening of the nanogouge is achieved at velocities and temperatures as low as 1.4 cm/s and <300°C, respectively, compared to >10 cm/s and >500°C in the microgouge, (iii) shear strength shows a rate-dependent weakening. Microstructural analysis of samples shows a three stage evolution: (i) cataclastic comminution and development of Riedel shear bands during the pre-weakening slip-hardening stage, (ii) interconnection of Riedel shears to form a continuous horizontal, localised shear band at the onset of weakening and (iii) evolution of the latter into a thin discrete shear zone with thickness <200 µm composed by a low-porosity aggregate of equigranular recrystallized crystals displaying triple junctions, at the attainment of steady-state weakening stage. Microstructures up to stage (i) are achieved in samples that did not undergo weakening. Despite both gouges show the same microstructural evolution, the initial grainsize of nanoparticles allows a more efficient localisation as the development of a discrete slip zone requires smaller amounts of slip. Our experimental results and microstructural observations shed some light on the critical role that extreme comminution and localisation play on the onset of weakening dominated by viscous flow at high strain rate in carbonate gouges.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Som, S.; Longman, D. E; Ramirez, A. I.
2011-03-01
Diesel engine performance and emissions are strongly coupled with fuel atomization and spray processes, which in turn are strongly influenced by injector flow dynamics. Modern engines employ micro-orifices with different orifice designs. It is critical to characterize the effects of various designs on engine performance and emissions. In this study, a recently developed primary breakup model (KH-ACT), which accounts for the effects of cavitation and turbulence generated inside the injector nozzle is incorporated into a CFD software CONVERGE for comprehensive engine simulations. The effects of orifice geometry on inner nozzle flow, spray, and combustion processes are examined by coupling themore » injector flow and spray simulations. Results indicate that conicity and hydrogrinding reduce cavitation and turbulence inside the nozzle orifice, which slows down primary breakup, increasing spray penetration, and reducing dispersion. Consequently, with conical and hydroground nozzles, the vaporization rate and fuel air mixing are reduced, and ignition occurs further downstream. The flame lift-off lengths are the highest and lowest for the hydroground and conical nozzles, respectively. This can be related to the rate of fuel injection, which is higher for the hydroground nozzle, leading to richer mixtures and lower flame base speeds. A modified flame index is employed to resolve the flame structure, which indicates a dual combustion mode. For the conical nozzle, the relative role of rich premixed combustion is enhanced and that of diffusion combustion reduced compared to the other two nozzles. In contrast, for the hydroground nozzle, the role of rich premixed combustion is reduced and that of non-premixed combustion is enhanced. Consequently, the amount of soot produced is the highest for the conical nozzle, while the amount of NOx produced is the highest for the hydroground nozzle, indicating the classical tradeoff between them.« less
Ochoa-Chavez, A S; Pieczyńska, A; Fiszka Borzyszkowska, A; Espinoza-Montero, P J; Siedlecka, E M
2018-06-01
In this study, the electrochemical degradation process of 5-fluorouracil (5-FU) in aqueous media was performed using a continuous flow reactor in an undivided cell (system I), and in a divided cell with a cationic membrane (Nafion ® 424) (system II). In system I, 75% of 5-FU degradation was achieved (50 mg L -1 ) with a applied current density j app = 150 A m -2 , volumetric flow rate qv = 13 L h -1 , after 6 h of electrolysis (k app = 0.004 min -1 ). The removal efficiency of 5-FU was higher (95%) when the concentration was 5 mg L -1 under the same conditions. Nitrates (22% of initial amount of N), fluorides (27%) and ammonium (10%) were quantified after 6 h of electrolysis. System II, 77% of 5-FU degradation was achieved (50 mg L -1 ) after 6 h of electrolysis (k app = 0.004 min -1 ). The degradation rate of 5-FU was complete when the concentration was 5 mg L -1 under the same conditions. Nitrates (29% of initial amount of N), fluorides (25%) and ammonium (5%) were quantified after 6 h of electrolysis. In addition, the main organic byproducts identified by mass spectroscopy were aliphatic compound with carbonyl and carboxyl functionalities. Due to, the mineralization of 5-FU with acceptable efficiency of 88% found in system II (j app of 200 A m -2 ), this system seems to be more promising in the cytostatic drug removal. Moreover the efficiency of 5-FU removal in diluted solutions is better in system II than in system I. Copyright © 2018 Elsevier Ltd. All rights reserved.
Combination of ozonation and photocatalysis for pharmaceutical wastewater treatment
NASA Astrophysics Data System (ADS)
Ratnawati, Enjarlis, Slamet
2017-11-01
The chemical oxygen demand (COD) and phenol removal from pharmaceutical wastewater were investigated using configuration of two circulation batch reactors in a series with ozonation and photocatalytic processes. The ozonation is conducted with O3/granulated activated carbon (O3/GAC), whereas photocatalysis with TiO2 that immobilized on pumice stone (PS-TiO2). The effect of circulation flow rate (10; 12; 15 L/min) and the amount PS-TiO2 (200 g, 250 g, 300 g) were examined. Wastewater of 20 L was circulated pass through the pipe that injected with O3 by the ozone generator, and subsequently flow through two GAC columns, and finally, go through photoreactor that contains photocatalyst PS-TiO2 which equipped with mercury lamp as a photon source. At a time interval, COD and phenol concentration were measured to assess the performance of the process. FESEM imaging confirmed that TiO2 was successfully impregnated on PS, as corroborated by EDX spectra. Meanwhile, degradation process indicated that the combined ozonation and photocatalytic processes (O3/GAC-TiO2) is more efficient compared to the ozonation and photocatalysis alone. For combination process with the circulation flow rate of 10 L/min and 300 g of PS-TiO2,the influent COD of around 1000 ppm are effectively degraded to a final effluent COD of 290 ppm (71% removal) and initial phenol concentration of 4.75 ppm down to 0 ppm for 4 h which this condition fulfill the discharge standards quality. Therefore, this portable prototype reactor is effective that can be used in the pharmaceutical wastewater treatment. For the future, this process condition will be developed for orientation on the industrial applications (portable equipment) since pharmaceutical industries produce wastewater relatively in the small amount.
Finite-time braiding exponents
NASA Astrophysics Data System (ADS)
Budišić, Marko; Thiffeault, Jean-Luc
2015-08-01
Topological entropy of a dynamical system is an upper bound for the sum of positive Lyapunov exponents; in practice, it is strongly indicative of the presence of mixing in a subset of the domain. Topological entropy can be computed by partition methods, by estimating the maximal growth rate of material lines or other material elements, or by counting the unstable periodic orbits of the flow. All these methods require detailed knowledge of the velocity field that is not always available, for example, when ocean flows are measured using a small number of floating sensors. We propose an alternative calculation, applicable to two-dimensional flows, that uses only a sparse set of flow trajectories as its input. To represent the sparse set of trajectories, we use braids, algebraic objects that record how trajectories exchange positions with respect to a projection axis. Material curves advected by the flow are represented as simplified loop coordinates. The exponential rate at which a braid stretches loops over a finite time interval is the Finite-Time Braiding Exponent (FTBE). We study FTBEs through numerical simulations of the Aref Blinking Vortex flow, as a representative of a general class of flows having a single invariant component with positive topological entropy. The FTBEs approach the value of the topological entropy from below as the length and number of trajectories is increased; we conjecture that this result holds for a general class of ergodic, mixing systems. Furthermore, FTBEs are computed robustly with respect to the numerical time step, details of braid representation, and choice of initial conditions. We find that, in the class of systems we describe, trajectories can be re-used to form different braids, which greatly reduces the amount of data needed to assess the complexity of the flow.
Finite-time braiding exponents.
Budišić, Marko; Thiffeault, Jean-Luc
2015-08-01
Topological entropy of a dynamical system is an upper bound for the sum of positive Lyapunov exponents; in practice, it is strongly indicative of the presence of mixing in a subset of the domain. Topological entropy can be computed by partition methods, by estimating the maximal growth rate of material lines or other material elements, or by counting the unstable periodic orbits of the flow. All these methods require detailed knowledge of the velocity field that is not always available, for example, when ocean flows are measured using a small number of floating sensors. We propose an alternative calculation, applicable to two-dimensional flows, that uses only a sparse set of flow trajectories as its input. To represent the sparse set of trajectories, we use braids, algebraic objects that record how trajectories exchange positions with respect to a projection axis. Material curves advected by the flow are represented as simplified loop coordinates. The exponential rate at which a braid stretches loops over a finite time interval is the Finite-Time Braiding Exponent (FTBE). We study FTBEs through numerical simulations of the Aref Blinking Vortex flow, as a representative of a general class of flows having a single invariant component with positive topological entropy. The FTBEs approach the value of the topological entropy from below as the length and number of trajectories is increased; we conjecture that this result holds for a general class of ergodic, mixing systems. Furthermore, FTBEs are computed robustly with respect to the numerical time step, details of braid representation, and choice of initial conditions. We find that, in the class of systems we describe, trajectories can be re-used to form different braids, which greatly reduces the amount of data needed to assess the complexity of the flow.
NASA Technical Reports Server (NTRS)
Converse, David
2011-01-01
Fan designs are often constrained by envelope, rotational speed, weight, and power. Aerodynamic performance and motor electrical performance are heavily influenced by rotational speed. The fan used in this work is at a practical limit for rotational speed due to motor performance characteristics, and there is no more space available in the packaging for a larger fan. The pressure rise requirements keep growing. The way to ordinarily accommodate a higher DP is to spin faster or grow the fan rotor diameter. The invention is to put two radially oriented stages on a single disk. Flow enters the first stage from the center; energy is imparted to the flow in the first stage blades, the flow is redirected some amount opposite to the direction of rotation in the fixed stators, and more energy is imparted to the flow in the second- stage blades. Without increasing either rotational speed or disk diameter, it is believed that as much as 50 percent more DP can be achieved with this design than with an ordinary, single-stage centrifugal design. This invention is useful primarily for fans having relatively low flow rates with relatively high pressure rise requirements.
Fluid Flow Nozzle Energy Harvesters
NASA Technical Reports Server (NTRS)
Sherrit, Stewart; Lee, Hyeong Jae; Walkenmeyer, Phillip; Winn, Tyler; Tosi, Luis Phillipe; Colonius, Tim
2015-01-01
Power generation schemes that could be used downhole in an oil well to produce about 1 Watt average power with long-life (decades) are actively being developed. A variety of proposed energy harvesting schemes could be used to extract energy from this environment but each of these has their own limitations that limit their practical use. Since vibrating piezoelectric structures are solid state and can be driven below their fatigue limit, harvesters based on these structures are capable of operating for very long lifetimes (decades); thereby, possibly overcoming a principle limitation of existing technology based on rotating turbo-machinery. An initial survey identified that spline nozzle configurations can be used to excite a vibrating piezoelectric structure in such a way as to convert the abundant flow energy into useful amounts of electrical power. This paper presents current flow energy harvesting designs and experimental results of specific spline nozzle/ bimorph design configurations which have generated suitable power per nozzle at or above well production analogous flow rates. Theoretical models for non-dimensional analysis and constitutive electromechanical model are also presented in this paper to optimize the flow harvesting system.
Fluid flow nozzle energy harvesters
NASA Astrophysics Data System (ADS)
Sherrit, Stewart; Lee, Hyeong Jae; Walkemeyer, Phillip; Winn, Tyler; Tosi, Luis Phillipe; Colonius, Tim
2015-04-01
Power generation schemes that could be used downhole in an oil well to produce about 1 Watt average power with long-life (decades) are actively being developed. A variety of proposed energy harvesting schemes could be used to extract energy from this environment but each of these has their own limitations that limit their practical use. Since vibrating piezoelectric structures are solid state and can be driven below their fatigue limit, harvesters based on these structures are capable of operating for very long lifetimes (decades); thereby, possibly overcoming a principle limitation of existing technology based on rotating turbo-machinery. An initial survey [1] identified that spline nozzle configurations can be used to excite a vibrating piezoelectric structure in such a way as to convert the abundant flow energy into useful amounts of electrical power. This paper presents current flow energy harvesting designs and experimental results of specific spline nozzle/ bimorph design configurations which have generated suitable power per nozzle at or above well production analogous flow rates. Theoretical models for non-dimensional analysis and constitutive electromechanical model are also presented in this paper to optimize the flow harvesting system.
Measuring surface flow velocity with smartphones: potential for citizen observatories
NASA Astrophysics Data System (ADS)
Weijs, Steven V.; Chen, Zichong; Brauchli, Tristan; Huwald, Hendrik
2014-05-01
Stream flow velocity is an important variable for discharge estimation and research on sediment dynamics. Given the influence of the latter on rating curves (stage-discharge relations), and the relative scarcity of direct streamflow measurements, surface velocity measurements can offer important information for, e.g., flood warning, hydropower, and hydrological science and engineering in general. With the growing amount of sensing and computing power in the hands of more outdoorsy individuals, and the advances in image processing techniques, there is now a tremendous potential to obtain hydrologically relevant data from motivated citizens. This is the main focus of the interdisciplinary "WeSenseIt" project, a citizen observatory of water. In this subproject, we investigate the feasibility of stream flow surface velocity measurements from movie clips taken by (smartphone-) cameras. First results from movie-clip derived velocity information will be shown and compared to reference measurements.
Effluent characterization from a conical pressurized fluid bed
NASA Technical Reports Server (NTRS)
Priem, R. J.; Rollbuhler, R. J.; Patch, R. W.
1977-01-01
To obtain useable corrosion and erosion results it was necessary to have data with several levels of particulate matter in the hot gases. One level of particulate loading was as low as possible so that ideally no erosion and only corrosion occurred. A conical fluidized bed was used to obtain some degree of filtration through the top of the bed which would not be highly fluidized. This would minimize the filtration required for the hot gases or conversely the amount of particulate matter in the hot gases after a given level of filtration by cyclones and/or filters. The data obtained during testing characterized the effluent from the bed at different test conditions. A range of bed heights, coal flows, air flows, limestone flows, and pressure are represented. These tests were made to determine the best operating conditions prior to using the bed to determine erosion and corrosion rates of typical turbine blade materials.
NASA Astrophysics Data System (ADS)
Stock, J. D.; Rosener, M.; Schmidt, K. M.; Hanshaw, M. N.; Brooks, B. A.; Tribble, G.; Jacobi, J.
2010-12-01
Pollution from coastal watersheds threatens the ecology of the nearshore, including tropical reefs. Suspended sediment concentrations off the reefs of Molokai, Hawaii, chronically exceed a toxic 10 mg/L, threatening reef ecosystems. We hypothesize that historic conversion of hillslope processes from soil creep to overland flow increased both magnitude and frequency of erosion. To create a process sediment budget, we used surficial and ecological mapping, hillslope and stream gages, and novel sensors to locate, quantify and model the generation of fine sediments polluting the reef. Ecological and geomorphic mapping from LiDAR and multi-spectral imagery located overland flow areas with vegetation cover below a threshold preventing erosion. Here, feral goat grazing exposed volcanic soils whose low matrix hydraulic conductivities (1-25 mm/hour) promote Horton overland flow. We instrumented steep, barren hillslopes with soil moisture sensors, overland flow meters, Parshal flumes, ISCO sediment samplers, and a rain gage and conducted repeat Tripod LiDAR and infiltration tests. To characterize soil resistance to overland flow erosion, we used a Cohesive Strength Meter (CSM) to simulate water stress. At the 13.5 km 2 watershed mouth we used a USGS stream gage with an ISCO sediment sampler to estimate total load. Over 3 years, storms triggered overland flow during rainfall intensities above 10-15 mm/hr. Overland flow meters indicate such flows can be up to 3 cm deep, with a tendency to deepen downslope. CSM tests indicate that these depths are insufficient to erode soils where vegetation is dense, but far above threshold values of 2-3 mm for bare soils. Sediment ratings curves for both hillslope and downstream catchment gages show clock-wise hysteresis during the first intense storms in the fall, becoming linear later in the season. During fall storms, sediment concentration is often 10X higher at a given stage. Revised annual lowering rates from experimental hillslopes are 1.5 cm/a (erosion pins), 1.4 cm/a (suspended sediment) and 1.6 cm/a (repeat Tripod LiDAR). These rates are at least 100-fold greater than the long-term river lowering rate of 0.13 mm/a. A sediment budget constructed by extrapolating hillslope lowering rates to the portions of the catchments mapped as unvegetated overland flow predicts a total yearly flux of ~ 6500 t, in agreement with the measured total of ~6200 t. Decadal records illustrate that rainfall intensities sufficient to generate overland flow occur for at least 8-10 hours every year, coincident with 1-3 large storm events. We hypothesize that high lowering rates reflect a combination of long-duration overland flow events, and availability of weathered soils that can be entrained by thin flow. It appears that generation of loose, seasonally weathered silt is a 1st order control on the amount of sediment exported to the reef. If climate change increases storm frequency or duration, or decreases vegetation cover, sediment loading to reefs could increase dramatically.
Ahluwalia, Rajesh K.; Papadias, Dionissios D.; Kariuki, Nancy N.; ...
2018-02-09
An electrochemical flow cell system with catalyst-ionomer ink deposited on glassy carbon is used to investigate the aqueous stability of commercial PtCo alloys under cyclic potentials. An on-line inductively coupled plasma-mass spectrometer, capable of real-time measurements, is used to resolve the anodic and cathodic dissolution of Pt and Co during square-wave and triangle-wave potential cycles. We observe Co dissolution at all potentials, distinct peaks in anodic and cathodic Pt dissolution rates above 0.9 V, and potential-dependent Pt and Co dissolution rates. The amount of Pt that dissolves cathodically is smaller than the amount that dissolves anodically if the upper potentialmore » limit (UPL) is lower than 0.9 V. At the highest UPL investigated, 1.0 V, the cathodic dissolution greatly exceeds the anodic dissolution. A non-ideal solid solution model indicates that the anodic dissolution can be associated with the electrochemical oxidation of Pt and PtOH to Pt 2+, and the cathodic dissolution to electrochemical reduction of a higher Pt oxide, PtO x (x > 1), to Pt 2+. Pt also dissolves oxidatively during the cathodic scans but in smaller amounts than due to the reductive dissolution of PtO x. The relative amounts Pt dissolving oxidatively as Pt and PtOH depend on the potential cycle and UPL.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ahluwalia, Rajesh K.; Papadias, Dionissios D.; Kariuki, Nancy N.
An electrochemical flow cell system with catalyst-ionomer ink deposited on glassy carbon is used to investigate the aqueous stability of commercial PtCo alloys under cyclic potentials. An on-line inductively coupled plasma-mass spectrometer, capable of real-time measurements, is used to resolve the anodic and cathodic dissolution of Pt and Co during square-wave and triangle-wave potential cycles. We observe Co dissolution at all potentials, distinct peaks in anodic and cathodic Pt dissolution rates above 0.9 V, and potential-dependent Pt and Co dissolution rates. The amount of Pt that dissolves cathodically is smaller than the amount that dissolves anodically if the upper potentialmore » limit (UPL) is lower than 0.9 V. At the highest UPL investigated, 1.0 V, the cathodic dissolution greatly exceeds the anodic dissolution. A non-ideal solid solution model indicates that the anodic dissolution can be associated with the electrochemical oxidation of Pt and PtOH to Pt 2+, and the cathodic dissolution to electrochemical reduction of a higher Pt oxide, PtO x (x > 1), to Pt 2+. Pt also dissolves oxidatively during the cathodic scans but in smaller amounts than due to the reductive dissolution of PtO x. The relative amounts Pt dissolving oxidatively as Pt and PtOH depend on the potential cycle and UPL.« less
Quantitative tomographic measurements of opaque multiphase flows
DOE Office of Scientific and Technical Information (OSTI.GOV)
GEORGE,DARIN L.; TORCZYNSKI,JOHN R.; SHOLLENBERGER,KIM ANN
2000-03-01
An electrical-impedance tomography (EIT) system has been developed for quantitative measurements of radial phase distribution profiles in two-phase and three-phase vertical column flows. The EIT system is described along with the computer algorithm used for reconstructing phase volume fraction profiles. EIT measurements were validated by comparison with a gamma-densitometry tomography (GDT) system. The EIT system was used to accurately measure average solid volume fractions up to 0.05 in solid-liquid flows, and radial gas volume fraction profiles in gas-liquid flows with gas volume fractions up to 0.15. In both flows, average phase volume fractions and radial volume fraction profiles from GDTmore » and EIT were in good agreement. A minor modification to the formula used to relate conductivity data to phase volume fractions was found to improve agreement between the methods. GDT and EIT were then applied together to simultaneously measure the solid, liquid, and gas radial distributions within several vertical three-phase flows. For average solid volume fractions up to 0.30, the gas distribution for each gas flow rate was approximately independent of the amount of solids in the column. Measurements made with this EIT system demonstrate that EIT may be used successfully for noninvasive, quantitative measurements of dispersed multiphase flows.« less
The effect of modeled recharge distribution on simulated groundwater availability and capture.
Tillman, F D; Pool, D R; Leake, S A
2015-01-01
Simulating groundwater flow in basin-fill aquifers of the semiarid southwestern United States commonly requires decisions about how to distribute aquifer recharge. Precipitation can recharge basin-fill aquifers by direct infiltration and transport through faults and fractures in the high-elevation areas, by flowing overland through high-elevation areas to infiltrate at basin-fill margins along mountain fronts, by flowing overland to infiltrate along ephemeral channels that often traverse basins in the area, or by some combination of these processes. The importance of accurately simulating recharge distributions is a current topic of discussion among hydrologists and water managers in the region, but no comparative study has been performed to analyze the effects of different recharge distributions on groundwater simulations. This study investigates the importance of the distribution of aquifer recharge in simulating regional groundwater flow in basin-fill aquifers by calibrating a groundwater-flow model to four different recharge distributions, all with the same total amount of recharge. Similarities are seen in results from steady-state models for optimized hydraulic conductivity values, fit of simulated to observed hydraulic heads, and composite scaled sensitivities of conductivity parameter zones. Transient simulations with hypothetical storage properties and pumping rates produce similar capture rates and storage change results, but differences are noted in the rate of drawdown at some well locations owing to the differences in optimized hydraulic conductivity. Depending on whether the purpose of the groundwater model is to simulate changes in groundwater levels or changes in storage and capture, the distribution of aquifer recharge may or may not be of primary importance. Published 2014. This article is a U.S. Government work and is in the public domain in the USA.
Feng, Yuping; Fornell, Jordina; Zhang, Huiyan; Solsona, Pau; Barό, Maria Dolors; Suriñach, Santiago; Sort, Jordi
2018-01-01
Open cell foams consisting of Fe and Fe-Mn oxides are prepared from metallic Fe and Mn powder precursors by the replication method using porous polyurethane (PU) templates. First, reticulated PU templates are coated by slurry impregnation. The templates are then thermally removed at 260 °C and the debinded powders are sintered at 1000 °C under N2 atmosphere. The morphology, structure, and magnetic properties are studied by scanning electron microscopy, X-ray diffraction and vibrating sample magnetometry, respectively. The obtained Fe and Fe-Mn oxide foams possess both high surface area and homogeneous open-cell structure. Hematite (α-Fe2O3) foams are obtained from the metallic iron slurry independently of the N2 flow. In contrast, the microstructure of the FeMn-based oxide foams can be tailored by adjusting the N2 flow. While the main phases for a N2 flow rate of 180 L/h are α-Fe2O3 and FeMnO3, the predominant phase for high N2 flow rates (e.g., 650 L/h) is Fe2MnO4. Accordingly, a linear magnetization versus field behavior is observed for the hematite foams, while clear hysteresis loops are obtained for the Fe2MnO4 foams. Actually, the saturation magnetization of the foams containing Mn increases from 5 emu/g to 52 emu/g when the N2 flow rate (i.e., the amount of Fe2MnO4) is increased. The obtained foams are appealing for a wide range of applications, such as electromagnetic absorbers, catalysts supports, thermal and acoustic insulation systems or wirelessly magnetically-guided porous objects in fluids. PMID:29439450
Feng, Yuping; Fornell, Jordina; Zhang, Huiyan; Solsona, Pau; Barό, Maria Dolors; Suriñach, Santiago; Pellicer, Eva; Sort, Jordi
2018-02-11
Open cell foams consisting of Fe and Fe-Mn oxides are prepared from metallic Fe and Mn powder precursors by the replication method using porous polyurethane (PU) templates. First, reticulated PU templates are coated by slurry impregnation. The templates are then thermally removed at 260 °C and the debinded powders are sintered at 1000 °C under N₂ atmosphere. The morphology, structure, and magnetic properties are studied by scanning electron microscopy, X-ray diffraction and vibrating sample magnetometry, respectively. The obtained Fe and Fe-Mn oxide foams possess both high surface area and homogeneous open-cell structure. Hematite (α-Fe₂O₃) foams are obtained from the metallic iron slurry independently of the N₂ flow. In contrast, the microstructure of the FeMn-based oxide foams can be tailored by adjusting the N₂ flow. While the main phases for a N₂ flow rate of 180 L/h are α-Fe₂O₃ and FeMnO₃, the predominant phase for high N₂ flow rates (e.g., 650 L/h) is Fe₂MnO₄. Accordingly, a linear magnetization versus field behavior is observed for the hematite foams, while clear hysteresis loops are obtained for the Fe₂MnO₄ foams. Actually, the saturation magnetization of the foams containing Mn increases from 5 emu/g to 52 emu/g when the N₂ flow rate (i.e., the amount of Fe₂MnO₄) is increased. The obtained foams are appealing for a wide range of applications, such as electromagnetic absorbers, catalysts supports, thermal and acoustic insulation systems or wirelessly magnetically-guided porous objects in fluids.
Song, Yang; Zhang, Ling-Lei; Li, Jia; Chen, Min; Zhang, Yao-Wen
2018-04-26
Hydrodynamic conditions play a key role in algal blooms, which have become an increasing threat to aquatic environments, especially reservoirs. Microcystis aeruginosa is a dominant species in algal blooms in reservoirs and releases large amounts of algal toxins during algal bloom events. The algal growth characteristics and the corresponding mechanism of the influence of hydrodynamic conditions were explored using custom hydraulic rotating devices. The long-term experimental results were as follows: (1) a moderate flow velocity increased the algal growth rate and prolonged algal lifetime relative to static water; (2) moderate water turbulence promoted energy metabolism and nutrient absorbance in algal cells; (3) moderate shear stress reduced oxidation levels in algal cells and improved algal cell morphology; (4) under hydrodynamic treatment, algal cell deformation was confirmed by scanning electron microscopy (SEM), and a high shear stress of 0.0104 Pa induced by a flow of 0.5 m/s may have destroyed cell morphology and disturbed reactive oxygen species (ROS) metabolism; (5) algal cell morphology evaluation (including circle ratio, eccentricity, diameter increasing rate, and deformation rate) was established; (6) based on algal growth status and specific effects, five independent intervals (including 'positive-promotion', 'middle-promotion', 'negative-promotion', 'transition', and 'inhibition') and the hydrodynamic threshold system (including flow velocity, turbulent dissipation, and shear stress) were established; and (7) for M. aeruginosa, the optimum flow velocity was 0.24 m/s, and the static-equivalent flow velocity was 0.47 m/s. These results provide a basic summary of the hydrodynamic effects on algal growth and a useful reference for the control of M. aeruginosa blooms in reservoirs. Copyright © 2018 Elsevier B.V. All rights reserved.
Minimum data requirement for neural networks based on power spectral density analysis.
Deng, Jiamei; Maass, Bastian; Stobart, Richard
2012-04-01
One of the most critical challenges ahead for diesel engines is to identify new techniques for fuel economy improvement without compromising emissions regulations. One technique is the precise control of air/fuel ratio, which requires the measurement of instantaneous fuel consumption. Measurement accuracy and repeatability for fuel rate is the key to successfully controlling the air/fuel ratio and real-time measurement of fuel consumption. The volumetric and gravimetric measurement principles are well-known methods for measurement of fuel consumption in internal combustion engines. However, the fuel flow rate measured by these methods is not suitable for either real-time control or real-time measurement purposes because of the intermittent nature of the measurements. This paper describes a technique that can be used to find the minimum data [consisting of data from just 2.5% of the non-road transient cycle (NRTC)] to solve the problem concerning discontinuous data of fuel flow rate measured using an AVL 733S fuel meter for a medium or heavy-duty diesel engine using neural networks. Only torque and speed are used as the input parameters for the fuel flow rate prediction. Power density analysis is used to find the minimum amount of the data. The results show that the nonlinear autoregressive model with exogenous inputs could predict the particulate matter successfully with R(2) above 0.96 using 2.5% NRTC data with only torque and speed as inputs.
NASA Astrophysics Data System (ADS)
Goh, Sien Fong
An experimental and numerical study of a turbulent smoke point diffusion flame in a quiescent and cross-flow condition was performed. The fuel mass flow rate of a turbulent smoke point flame was determined at a quiescent condition and in cross-flow with velocity ranging from 2 to 4 m/s. This fuel mass flow rate is defined as the Critical Fuel Mass Flow Rate (CFMFR). At a fuel mass flow rate below the CFMFR the flame produces smoke. In the dilution study, an amount of inert gas (nitrogen) was added to the fuel stream to achieve the smoke point condition for ten different fractions of CFMFR. From this dilution study, three regions were defined, the chemically-dominated region, transition region, and momentum-dominated region. The first objective of this study was to determine the factors behind the distinction of these three regions. The second objective was to understand the effect of cross-flow velocity on the smoke point flame structure. The flame temperature, radiation, geometrical dimension of flame, velocity, and global emissions and in-flame species concentration were measured. The third objective was to study a numerical model that can simulate the turbulent smoke point flame structure. The dilution study showed that the flames in quiescent condition and in the 3.5 and 4 m/s cross-flow condition had the chemically-dominated region at 5% to 20% CFMFR, the transition region at 20% to 40% CFMFR, and the momentum-dominated region at 40% to 100% CFMFR. On the other hand, the flame in cross-flow of 2 to 3 m/s showed the chemically-dominated region at 5% to 10% CFMFR, the transition region at 10% to 30% CFMFR, and the momentum-dominated region at 30% to 100% CFMFR. The chemically-dominated flame had a sharp dual-peak structure for the flame temperature, CO2 and NO concentration profiles at 25% and 50% flame length. However, the momentum-dominated region flame exhibited a dual peak structure only at 25% flame length. The decrease of flow rate from 30% to 10% CFMFR showed an increase of flame length. The LII study showed that the soot concentration increased with the decrease of the turbulence intensity in the momentum dominated region (tested on the 100% and 60% CFMFR). The cross-flow velocity had a non-monotonic effects on the flame. The evidences could be observed from the flame length and the soot concentration results. The flame length showed a decrease when the cross-flow velocity increased from 2 to 3 m/s. The numerical model was fairly adequate in qualitatively predicting a smoke point turbulent diffusion flame structure in a cross-flow and quiescent condition. The model failed in the prediction of a laminar flame. The model showed a good agreement between experimental and numerical results for O 2 concentration and flame temperature. (Abstract shortened by UMI.)
Valorisation of waste tyre by pyrolysis in a moving bed reactor.
Aylón, E; Fernández-Colino, A; Murillo, R; Navarro, M V; García, T; Mastral, A M
2010-07-01
The aim of this work is to assess the behaviour of a moving bed reactor, based on a screw transporter design, in waste tyre pyrolysis under several experimental conditions. Waste tyre represents a significant problem in developed countries and it is necessary to develop new technology that could easily process big amounts of this potentially raw material. In this work, the influence of the main pyrolysis process variables (temperature, solid residence time, mass flow rate and inert gas flow) has been studied by a thorough analysis of product yields and properties. It has been found that regardless the process operational parameters, a total waste tyre devolatilisation is achieved, producing a pyrolytic carbon black with a volatile matter content under 5 wt.%. In addition, it has been proven that, in the range studied, the most influencing process variables are temperature and solid mass flow rate, mainly because both variables modify the gas residence time inside the reactor. In addition, it has been found that the modification of these variables affects to the chemical properties of the products. This fact is mainly associated to the different cracking reaction of the primary pyrolysis products. Copyright (c) 2009 Elsevier Ltd. All rights reserved.
Valorisation of waste tyre by pyrolysis in a moving bed reactor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aylon, E.; Fernandez-Colino, A.; Murillo, R., E-mail: ramonm@icb.csic.e
2010-07-15
The aim of this work is to assess the behaviour of a moving bed reactor, based on a screw transporter design, in waste tyre pyrolysis under several experimental conditions. Waste tyre represents a significant problem in developed countries and it is necessary to develop new technology that could easily process big amounts of this potentially raw material. In this work, the influence of the main pyrolysis process variables (temperature, solid residence time, mass flow rate and inert gas flow) has been studied by a thorough analysis of product yields and properties. It has been found that regardless the process operationalmore » parameters, a total waste tyre devolatilisation is achieved, producing a pyrolytic carbon black with a volatile matter content under 5 wt.%. In addition, it has been proven that, in the range studied, the most influencing process variables are temperature and solid mass flow rate, mainly because both variables modify the gas residence time inside the reactor. In addition, it has been found that the modification of these variables affects to the chemical properties of the products. This fact is mainly associated to the different cracking reaction of the primary pyrolysis products.« less
A model for oxygen conservation associated with titration during pediatric oxygen therapy.
Wu, Grace; Wollen, Alec; Himley, Stephen; Austin, Glenn; Delarosa, Jaclyn; Izadnegahdar, Rasa; Ginsburg, Amy Sarah; Zehrung, Darin
2017-01-01
Continuous oxygen treatment is essential for managing children with hypoxemia, but access to oxygen in low-resource countries remains problematic. Given the high burden of pneumonia in these countries and the fact that flow can be gradually reduced as therapy progresses, oxygen conservation through routine titration warrants exploration. To determine the amount of oxygen saved via titration during oxygen therapy for children with hypoxemic pneumonia. Based on published clinical data, we developed a model of oxygen flow rates needed to manage hypoxemia, assuming recommended flow rate at start of therapy, and comparing total oxygen used with routine titration every 3 minutes or once every 24 hours versus no titration. Titration every 3 minutes or every 24 hours provided oxygen savings estimated at 11.7% ± 5.1% and 8.1% ± 5.1% (average ± standard error of the mean, n = 3), respectively. For every 100 patients, 44 or 30 kiloliters would be saved-equivalent to 733 or 500 hours at 1 liter per minute. Ongoing titration can conserve oxygen, even performed once-daily. While clinical validation is necessary, these findings could provide incentive for the routine use of pulse oximeters for patient management, as well as further development of automated systems.
Kostanyan, Artak E; Shishilov, Oleg N
2018-06-01
Multiple dual mode counter-current chromatography (MDM CCC) separation processes with semi-continuous large sample loading consist of a succession of two counter-current steps: with "x" phase (first step) and "y" phase (second step) flow periods. A feed mixture dissolved in the "x" phase is continuously loaded into a CCC machine at the beginning of the first step of each cycle over a constant time with the volumetric rate equal to the flow rate of the pure "x" phase. An easy-to-use calculating machine is developed to simulate the chromatograms and the amounts of solutes eluted with the phases at each cycle for steady-state (the duration of the flow periods of the phases is kept constant for all the cycles) and non-steady-state (with variable duration of alternating phase elution steps) separations. Using the calculating machine, the separation of mixtures containing up to five components can be simulated and designed. Examples of the application of the calculating machine for the simulation of MDM CCC processes are discussed. Copyright © 2018 Elsevier B.V. All rights reserved.
Lapis, Trina J; Penner, Michael H; Balto, Amy S; Lim, Juyun
2017-10-01
Since starch is a significant part of human diet, its oral detection would be highly beneficial. This study was designed to determine whether starch or its degradation products can be tasted and what factors influence its perception. Subjects were asked 1) to taste 8% raw and cooked starch samples for 5, 15, and 35 s and rate perceived intensities of sweetness and "other" taste (i.e., other than sweet), 2) to donate saliva to obtain salivary flow rate (mg/s) and salivary α-amylase activity (per mg saliva), and 3) to fill out a carbohydrate consumption survey. Subsequently, in vitro hydrolysis of starch was performed; saliva was collected from 5 subjects with low and high amylase activities and reacted with 8% raw and cooked starch at 2, 15, and 30 s. Hydrolysis products were then quantified using a High performance liquid chromatography. The results showed cooking increased the digestibility of starch such that the amount of hydrolysis products increased with reaction time. However, cooking did not influence taste ratings, nor were they influenced by tasting time. Subjects' salivary amylase activities were associated with the efficacy of their saliva to degrade starch, in particular cooked starch, and thus the amount of maltooligosaccharide products generated. Effective α-amylase activity [i.e. α-amylase activity (per mg saliva) × salivary flow rate (mg/s)] and carbohydrate consumption score (i.e. consumption frequency × number of servings) were also independently associated with sensory taste ratings. Human perception of starch is undoubtedly complex as shown in this study; the data herein point to the potential roles of salivary α-amylase activity and carbohydrate consumption in the perception of cooked starch. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Development of a Compact & Easy-to-Use 3-D Camera for High Speed Turbulent Flow Fields
2013-12-05
resolved. Also, in the case of a single camera system, the use of an aperture greatly reduces the amount of collected light. The combination of these...a study on wall-bounded turbulence [Sheng_2006]. Nevertheless, these techniques are limited to small measurement volumes, while maintaining a high...It has also been adapted to kHz rates using high-speed cameras for aeroacoustic studies (see Violato et al. [17, 18]. Tomo-PIV, however, has some
Simultaneous Extraction of Lithium and Hydrogen from Seawater
2011-08-22
to the anode and cathode were determined by ion chromatography . Anions were analyzed by Anion Ion Chromatography (Instrument Dionex ICS-1500, Column...and oxygen gases coming out of the cell were collected and the amount was measured volumetrically. Ion chromatography : Ions in seawater diffused from... Dionex AS9-HC; AG9-HC Guard, eluent: 9.00 mM Na2CO3, flow rate: 1.25 mL/min, and sample loop was 25 μL). Cations were analyzed by Cation Ion
NASA Astrophysics Data System (ADS)
Cullis, J. D.; Gillis, C.; Drummond, J. D.; Garcia, T.; Kilroy, C.; Larned, S.; Hassan, M. A.
2010-12-01
Didymosphenia geminata (didymo) was introduced into a New Zealand river in 2004, and since then has dramatically spread to cover the beds of many rivers with extremely dense and extensive mats. Successful management is hampered by the fact that much is still unknown about the factors affecting the growth of this nuisance species. We synthesized available data on the distribution of D. geminata in New Zealand rivers to determine how physical and chemical system conditions (flow, bed disturbance, nutrients, and light) affect the growth and persistence of this organism. Here we assess results from bi-weekly surveys performed over a full year on two rivers where didymo was first observed in New Zealand; the Oreti and Mararoa. We used the data to test the hypotheses that the development of thick, dense mats requires high light levels but is inversely proportional to nutrient levels, and that mat persistence is controlled by the frequency of flow events that produce bed sediment transport. Observed regrowth between disturbance events was found to be inversely correlated with nutrient availability. The seasonal availability of light did not correlate with variations in growth rate, but this did not account for specific characteristics of the different sites such as aspect, shading, flow depth and turbidity that will all impact on the amount of available light reaching the streambed. The results clearly indicate that the time-history of flow and nutrient levels is critical to evaluating the growth and persistence of D. geminata and that additional site specific information is necessary to determine the role of bed stability and the amount of available light reaching the streambed.
El-Seddik, Mostafa M; Galal, Mona M; Radwan, A G; Abdel-Halim, Hisham S
2016-01-01
This paper addresses a modified kinetic-hydraulic model for up-flow anaerobic sludge blanket (UASB) reactor aimed to treat wastewater of biodegradable organic substrates as acetic acid based on Van der Meer model incorporated with biological granules inclusion. This dynamic model illustrates the biomass kinetic reaction rate for both direct and indirect growth of microorganisms coupled with the amount of biogas produced by methanogenic bacteria in bed and blanket zones of reactor. Moreover, the pH value required for substrate degradation at the peak specific growth rate of bacteria is discussed for Andrews' kinetics. The sensitivity analyses of biomass concentration with respect to fraction of volume of reactor occupied by granules and up-flow velocity are also demonstrated. Furthermore, the modified mass balance equations of reactor are applied during steady state using Newton Raphson technique to obtain a suitable degree of freedom for the modified model matching with the measured results of UASB Sanhour wastewater treatment plant in Fayoum, Egypt.
NASA Astrophysics Data System (ADS)
Kumar, Prince; Pandey, K. M., Dr.
2017-08-01
Heat transfer is a most important phenomenon that influence the performance of working device. To date several attempts have been made by researchers to minimize the size of heat exchangers in order to reduce the cost. Earlier we use some conventional fluids (water, air, engine oil etc.) for cooling of automobile, refrigeration and some other industrial applications. But it is observed here that by using these fluids there is curb and hindrance in heat transfer rate because of very low thermal conductivity. From last ten-years new generation fluid introduced known as nanofluid. To increase the thermal conductivity of base fluid some amount of nanoparticles is added. Nanofluid have combined properties of nanoparticles as well as base fluid. Researcher found that heat transfer rate fully dependent of the thermal conductivity of nanoparticles as well as nanoparticle size diameter and volume concentration. This review paper summarised the recent research on enhancement of heat transfer and thermal performance of nanofluid as coolant for industrial applications.
Morais, Frida Mariana; Buchholz, Friederike; Maskow, Thomas
2014-01-01
Any growth or bioconversion in biofilms is accompanied by the release of heat. The heat (in J) is tightly related to the stoichiometry of the respective process via law of Hess, and the heat production rate (in W or J/s) is additionally related to the process kinetics. This heat and the heat production rate can nowadays be measured by modern calorimetry with extremely high sensitivity. Flow-through calorimetry allows the measurement of bioprocesses in biofilms in real time, without the need of invasive sample preparation and disturbing of biofilm processes. Furthermore, it can be applied for long-term measurements and is even applicable to turbid media. Chip or miniaturized calorimeters have the additional advantages of extremely short thermal equilibration times and the requirement of very small amounts of media and chemicals. The precision of flow-through chip calorimeters (about 3 mW/L) allows the detection of early stages of biofilm development (about 10(5) bacteria cm(-2)).
Membrane reactor for water detritiation: a parametric study on operating parameters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mascarade, J.; Liger, K.; Troulay, M.
2015-03-15
This paper presents the results of a parametric study done on a single stage finger-type packed-bed membrane reactor (PBMR) used for heavy water vapor de-deuteration. Parametric studies have been done on 3 operating parameters which are: the membrane temperature, the total feed flow rate and the feed composition through D{sub 2}O content variations. Thanks to mass spectrometer analysis of streams leaving the PBMR, speciation of deuterated species was achieved. Measurement of the amounts of each molecular component allowed the calculation of reaction quotient at the packed-bed outlet. While temperature variation mainly influences permeation efficiency, feed flow rate perturbation reveals dependencemore » of conversion and permeation properties to contact time between catalyst and reacting mixture. The study shows that isotopic exchange reactions occurring on the catalyst particles surface are not thermodynamically balanced. Moreover, the variation of the heavy water content in the feed exhibits competition between permeation and conversion kinetics.« less
Microfluidics for producing poly (lactic-co-glycolic acid)-based pharmaceutical nanoparticles.
Li, Xuanyu; Jiang, Xingyu
2017-12-24
Microfluidic chips allow the rapid production of a library of nanoparticles (NPs) with distinct properties by changing the precursors and the flow rates, significantly decreasing the time for screening optimal formulation as carriers for drug delivery compared to conventional methods. The batch-to-batch reproducibility which is essential for clinical translation is achieved by precisely controlling the precursors and the flow rate, regardless of operators. Poly (lactic-co-glycolic acid) (PLGA) is the most widely used Food and Drug Administration (FDA)-approved biodegradable polymers. Researchers often combine PLGA with lipids or amphiphilic molecules to assemble into a core/shell structure to exploit the potential of PLGA-based NPs as powerful carriers for cancer-related drug delivery. In this review, we discuss the advantages associated with microfluidic chips for producing PLGA-based functional nanocomplexes for drug delivery. These laboratory-based methods can readily scale up to provide sufficient amount of PLGA-based NPs in microfluidic chips for clinical studies and industrial-scale production. Copyright © 2017. Published by Elsevier B.V.
Germani, José Carlos
2013-01-01
Macrophomina phaseolina was cultivated in complex and simple media for the production of extracellular lipolytic enzymes. Culture supernatants were batch foam fractionated for the recovery of these enzymes, and column design and operation included the use of P 2 frit (porosity 40 to 100 μm), air as sparging gas at variable flow rates, and Triton X-100 added at the beginning or gradually in aliquots. Samples taken at intervals showed the progress of the kinetic and the efficiency parameters. Best results were obtained with the simple medium supernatant by combining the stepwise addition of small amounts of the surfactant with the variation of the air flow rates along the separation. Inert proteins were foamed out first, and the subsequent foamate was enriched in the enzymes, showing estimated activity recovery (R), enrichment ratio (E), and purification factor (P) of 45%, 34.7, and 2.9, respectively. Lipases were present in the enriched foamate. PMID:23738054
NASA Technical Reports Server (NTRS)
Joerns, J. C.
1986-01-01
Pressure regulated and flow timed to control amount dispensed. Dispenser provides measured amount of water for reconstituting dehydrated foods and beverages. Dispenser holds food or beverage package while being filled with either cold or room-temperature water. Other uses might include dispensing of fluids or medicine. Pressure regulator in dispenser reduces varying pressure of water supply to constant pressure. Electronic timer stops flow after predetermined length of time. Timed flow at regulated pressure ensures controlled volume of water dispensed.
NASA Astrophysics Data System (ADS)
Sakakibara, Koichi; Tsujimura, Maki; Song, Xianfang; Zhang, Jie
2014-05-01
Groundwater recharge is a crucial hydrological process for effective water management especially in arid/ semi-arid regions. However, the insufficient number of specific research regarding groundwater recharge process has been reported previously. Intensive field surveys were conducted during rainy season, mid dry season, and end of dry season, in order to clarify comprehensive groundwater recharge and flow regime of Wangkuai watershed in a headwater, which is a main recharge zone of North China Plain. The groundwater, spring, stream water and lake water were sampled, and inorganic solute constituents and stable isotopes of oxygen 18 and deuterium were determined on all water samples. Also the stream flow rate was observed. The solute ion concentrations and stable isotopic compositions show that the most water of this region can be characterized by Ca-HCO3 type and the main water source is precipitation which is affected by altitude effect of stable isotopes. In addition, the river and reservoir of the area seem to recharge the groundwater during rainy season, whereas interaction between surface water and groundwater does not become dominant gradually after the rainy season. The inversion analysis applied in Wangkuai watershed using simple mixing model represents an existing multi-flow systems which shows a distinctive tracer signal and flow rate. In summary, the groundwater recharged at different locations in the upper stream of Wangkuai reservoir flows downward to alluvial fan with a certain amount of mixing together, also the surface water recharges certainly the groundwater in alluvial plain in the rainy season.
Martínez, Aingeru; Pérez, Javier; Molinero, Jon; Sagarduy, Mikel; Pozo, Jesús
2015-01-15
Although temporary streams represent a high proportion of the total number and length of running waters, historically the study of intermittent streams has received less attention than that of perennial ones. The goal of the present study was to assess the effects of flow cessation on litter decomposition in calcareous streams under oceanic climate conditions. For this, leaf litter of alder was incubated in four streams (S1, S2, S3 and S4) with different flow regimes (S3 and S4 with zero-flow periods) from northern Spain. To distinguish the relative importance and contribution of decomposers and detritivores, fine- and coarse-mesh litter bags were used. We determined processing rates, leaf-C, -N and -P concentrations, invertebrate colonization in coarse bags and benthic invertebrates. Decomposition rates in fine bags were similar among streams. In coarse bags, only one of the intermittent streams, S4, showed a lower rate than that in the other ones as a consequence of lower invertebrate colonization. The material incubated in fine bags presented higher leaf-N and -P concentrations than those in the coarse ones, except in S4, pointing out that the decomposition in this stream was driven mainly by microorganisms. Benthic macroinvertebrate and shredder density and biomass were lower in intermittent streams than those in perennial ones. However, the bags in S3 presented a greater amount of total macroinvertebrates and shredders comparing with the benthos. The most suitable explanation is that the fauna find a food substrate in bags less affected by calcite precipitation, which is common in the streambed at this site. Decomposition rate in coarse bags was positively related to associated shredder biomass. Thus, droughts in streams under oceanic climate conditions affect mainly the macroinvertebrate detritivore activity, although macroinvertebrates may show distinct behavior imposed by the physicochemical properties of water, mainly travertine precipitation, which can override the flow intermittence effects. Copyright © 2014. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Boivin, Maxime; Buffin-Bélanger, Thomas; Piégay, Hervé
2017-02-01
Semi-alluvial rivers of the Gaspé Peninsula, Québec, are prone to produce and transport vast quantities of large wood (LW). The high rate of lateral erosion owing to high energy flows and noncohesive banks is the main process leading to the recruitment of large wood, which in turn initiates complex patterns of wood accumulation and reentrainment within the active channel. The delta of the Saint-Jean River (SJR) has accumulated large annual wood fluxes since 1960 that culminated in a wood raft of > 3-km in length in 2014. To document the kinetics of large wood on the main channel of SJR, four annual surveys were carried out from 2010 to 2013 to locate and describe > 1000 large wood jams (LWJ) and 2000 large wood individuals (LWI) along a 60-km river section. Airborne and ground photo/video images were used to estimate the wood volume introduced by lateral erosion and to identify local geomorphic conditions that control wood mobility and deposits. Video camera analysis allowed the examination of transport rates from three hydrometeorological events for specific river sections. Results indicate that the volume of LW recruited between 2010 and 2013 represents 57% of the total LW production over the 2004-2013 period. Volumes of wood deposited along the 60-km section were four times higher in 2013 than in 2010. Increases in wood amount occurred mainly in upper alluvial sections of the river, whereas decreases were observed in the semi-alluvial middle sections. Observations suggest that the 50-year flood event of 2010 produced large amounts of LW that were only partly exported out of the basin so that a significant amount was still available for subsequent floods. Large wood storage continued after this flood until a similar flood or an ice-breakup event could remobilise these LW accumulations into the river corridor. Ice-jam floods transport large amounts of wood during events with fairly low flow but do not contribute significantly to recruitment rates (ca. 10 to 30% early). It is fairly probable that the wood export peak observed in 2012 at the river mouth, where no flood occurred and which is similar to the 1-in 10-year flood of 2010, is mainly linked to such ice-break events that occurred in March 2012.
Use of a Terrestrial LIDAR Sensor for Drift Detection in Vineyard Spraying
Gil, Emilio; Llorens, Jordi; Llop, Jordi; Fàbregas, Xavier; Gallart, Montserrat
2013-01-01
The use of a scanning Light Detection and Ranging (LIDAR) system to characterize drift during pesticide application is described. The LIDAR system is compared with an ad hoc test bench used to quantify the amount of spray liquid moving beyond the canopy. Two sprayers were used during the field test; a conventional mist blower at two air flow rates (27,507 and 34,959 m3·h−1) equipped with two different nozzle types (conventional and air injection) and a multi row sprayer with individually oriented air outlets. A simple model based on a linear function was used to predict spray deposit using LIDAR measurements and to compare with the deposits measured over the test bench. Results showed differences in the effectiveness of the LIDAR sensor depending on the sprayed droplet size (nozzle type) and air intensity. For conventional mist blower and low air flow rate; the sensor detects a greater number of drift drops obtaining a better correlation (r = 0.91; p < 0.01) than for the case of coarse droplets or high air flow rate. In the case of the multi row sprayer; drift deposition in the test bench was very poor. In general; the use of the LIDAR sensor presents an interesting and easy technique to establish the potential drift of a specific spray situation as an adequate alternative for the evaluation of drift potential. PMID:23282583
The relationship between turbidity of mouth-rinsed water and oral health status.
Takeuchi, Susumu; Ueno, Masayuki; Takehara, Sachiko; Pham, Thuy Anh Vu; Hakuta, Chiyoko; Morishima, Seiji; Shinada, Kayoko; Kawaguchi, Yoko
2013-01-01
The purpose of this study was to examine the relationship between turbidity of mouth rinsed water and oral health status such as dental and periodontal conditions, oral hygiene status, flow rate of saliva and oral bacteria. Subjects were 165 patients who visited the Dental Hospital, Tokyo Medical and Dental University. Oral health status, including dental and periodontal conditions, oral hygiene status and flow rate of saliva, was clinically examined. The turbidity was measured with a turbidimeter. Quantification of Fusobacterium spp, Porphyromonas gingivalis, Tannerella forsythia, Treponema denticola and total bacteria levels was performed using real-time PCR. The Pearson correlation and multiple regression analysis were used to explore the associations between the turbidity and oral health parameters. The turbidity showed significant correlations with the number of decayed teeth and deep pockets, the plaque index, extent of tongue coating and Fusobacterium spp, P. gingivalis, T. forsythia, T. denticola and total bacteria levels. In a multiple regression model, the turbidity was negatively associated with the flow rate of saliva and positively associated with the total number of bacteria (p < 0.001). Current findings suggested that turbidity of mouth rinsed water could be used as an indicator to evaluate oral health condition and the amount of bacteria in the oral cavity. In addition, the turbiditimeter appeared as a simple and objective device for screening abnormality of oral health condition at chair side as well as community-based research.
Aspects of turbulent-shear-layer dynamics and mixing
NASA Astrophysics Data System (ADS)
Slessor, Michael David
Experiments have been conducted in the GALCIT Supersonic Shear Layer Facility to investigate some aspects of high-Reynolds-number, turbulent, shearlayer flows in both incompressible- and compressible-flow regimes. Experiments designed to address several issues were performed; effects of inflow boundary conditions, freestream conditions (supersonic/subsonic flow), and compressibility, on both large-scale dynamics and small-scale mixing, are described. Chemically-reacting and non-reacting flows were investigated, the former relying on the (H2 + NO/F2) chemical system, in the fast-kinetic regime, to infer the structure and amount of molecular-scale mixing through use of "flip" experiments. A variety of experimental techniques, including a color-schlieren visualization system developed as part of this work, were used to study the flows. Both inflow conditions and compressibility are found to have significant effects on the flow. In particular, inflow conditions are "remembered" for long distances downstream, a sensitivity similar to that observed in low-dimensionality, non-linear (chaotic) systems. The global flowfields (freestreams coupled by the shear layer) of transonic flows exhibit a sensitivity to imposed boundary conditions, i. e., local area ratios. A previously-proposed mode-selection rule for turbulent-structure convection speeds, based on the presence of a lab-frame subsonic freestream, was experimentally demonstrated to be incorrect. Compressibility, when decoupled from all other parameters, e.g., Reynolds number, velocity and density ratios, etc., reduces laxge-scale entrainment and turbulent growth, but slightly enhances smallscale mixing, with an associated change in the structure of the molecularly-mixed fluid. This reduction in shear-layer growth rate is examined and a new parameter that interprets compressibility as an energy-exchange mechanism is proposed. The parameter reconciles and collapses experimentally-observed growth rates.
Aspects of turbulent-shear-layer dynamics and mixing
NASA Astrophysics Data System (ADS)
Slessor, Michael David
Experiments have been conducted in the GALCIT Supersonic Shear Layer Facility to investigate some aspects of high-Reynolds-number, turbulent, shear-layer flows in both incompressible- and compressible-flow regimes. Experiments designed to address several issues were performed; effects of inflow boundary conditions, freestream conditions (supersonic/subsonic flow), and compressibility, on both large-scale dynamics and small-scale mixing, are described. Chemically-reacting and non-reacting flows were investigated, the former relying on the (Hsb2 + NO)/Fsb2 chemical system, in the fast-kinetic regime, to infer the structure and amount of molecular-scale mixing through use of "flip" experiments. A variety of experimental techniques, including a color-schlieren visualization system developed as part of this work, were used to study the flows. Both inflow conditions and compressibility are found to have significant effects on the flow. In particular, inflow conditions are "remembered" for long distances downstream, a sensitivity similar to that observed in low-dimensionality, non-linear (chaotic) systems. The global flowfields (freestreams coupled by the shear layer) of transonic flows exhibit a sensitivity to imposed boundary conditions, a.e., local area ratios. A previously-proposed mode-selection rule for turbulent-structure convection speeds, based on the presence of a lab-frame subsonic freestream, was experimentally demonstrated to be incorrect. Compressibility, when decoupled from ail other parameters, e.g., Reynolds number, velocity and density ratios, etc., reduces large-scale entrainment and turbulent growth, but slightly enhances small-scale mixing, with an associated change in the structure of the molecularly-mixed fluid. This reduction in shear-layer growth rate is examined and a new parameter that interprets compressibility as an energy-exchange mechanism is proposed. The parameter reconciles and collapses experimentally-observed growth rates.
Grubbs, J.W.; Pittman, J.R.
1997-01-01
Water flow and quality data were collected from December 1994 to September 1995 to evaluate variations in discharge, water quality, and chemical fluxes (loads) through Perdido Bay, Florida. Data were collected at a cross section parallel to the U.S. Highway 98 bridge. Discharges measured with an acoustic Doppler current profiler (ADCP) and computed from stage-area and velocity ratings varied roughly between + or - 10,000 cubic feet per second during a typical tidal cycle. Large reversals in flow direction occurred rapidly (less than 1 hour), and complete reversals (resulting in near peak net-upstream or downstream discharges) occurred within a few hours of slack water. Observations of simultaneous upstream and downstream flow (bidirectional flow) were quite common in the ADCP measurements, with opposing directions of flow occurring predominantly in vertical layers. Continuous (every 15 minutes) discharge data were computed for the period from August 18, 1995, to September 28, 1995, and filtered daily mean discharge values were computed for the period from August 19 to September 26, 1995. Data were not computed prior to August 18, 1995, either because of missing data or because the velocity rating was poorly defined (because of insufficient data) for the period prior to landfall of hurricane Erin (August 3, 1995). The results of the study indicate that acoustical techniques can yield useful estimates of continuous (instantaneous) discharge in Perdido Bay. Useful estimates of average daily net flow rates can also be obtained, but the accuracy of these estimates will be limited by small rating shifts that introduce bias into the instantaneous values that are used to compute the net flows. Instantaneous loads of total nitrogen ranged from -180 to 220 grams per second for the samples collected during the study, and instantaneous loads of total phosphorous ranged from -10 to 11 grams per second (negative loads indicate net upstream transport). The chloride concentrations from the water samples collected from Perdido Bay indicated a significant amount of mixing of saltwater and freshwater. Mixing effects could greatly reduce the accuracy of estimates of net loads of nutrients or other substances. The study results indicate that acoustical techniques can yield acceptable estimates of instantaneous loads in Perdido Bay. However, estimates of net loads should be interpreted with great caution and may have unacceptably large errors, especially when saltwater and freshwater concentrations differ greatly.
Senior, Lisa A.; Goode, Daniel J.
2017-06-06
A previously developed regional groundwater flow model was used to simulate the effects of changes in pumping rates on groundwater-flow paths and extent of recharge discharging to wells for a contaminated fractured bedrock aquifer in southeastern Pennsylvania. Groundwater in the vicinity of the North Penn Area 7 Superfund site, Montgomery County, Pennsylvania, was found to be contaminated with organic compounds, such as trichloroethylene (TCE), in 1979. At the time contamination was discovered, groundwater from the underlying fractured bedrock (shale) aquifer was the main source of supply for public drinking water and industrial use. As part of technical support to the U.S. Environmental Protection Agency (EPA) during the Remedial Investigation of the North Penn Area 7 Superfund site from 2000 to 2005, the U.S. Geological Survey (USGS) developed a model of regional groundwater flow to describe changes in groundwater flow and contaminant directions as a result of changes in pumping. Subsequently, large decreases in TCE concentrations (as much as 400 micrograms per liter) were measured in groundwater samples collected by the EPA from selected wells in 2010 compared to 2005‒06 concentrations.To provide insight on the fate of potentially contaminated groundwater during the period of generally decreasing pumping rates from 1990 to 2010, steady-state simulations were run using the previously developed groundwater-flow model for two conditions prior to extensive remediation, 1990 and 2000, two conditions subsequent to some remediation 2005 and 2010, and a No Pumping case, representing pre-development or cessation of pumping conditions. The model was used to (1) quantify the amount of recharge, including potentially contaminated recharge from sources near the land surface, that discharged to wells or streams and (2) delineate the areas contributing recharge that discharged to wells or streams for the five conditions.In all simulations, groundwater divides differed from surface-water divides, partly because of differences in stream elevations and because of geologic structure and pumping. In the 1990 and 2000 simulations, all recharge in and near the vicinity of North Penn Area 7 discharged to wells, but in the 2005 and 2010 simulations some recharge in this area discharged to streams, indicating possible discharge of contaminated groundwater from North Penn Area 7 sources to streams. As the amount of groundwater withdrawals by wells has declined since 1990, the area contributing recharge to wells in the vicinity of North Penn Area 7 has decreased.To determine the effect of changes in pumping on flow paths and possible flow-path-related contributions to the observed changes in spatial distribution of contaminants in groundwater from 2005 to 2010, the USGS conducted simulations using the previously developed regional groundwater-flow model using reported pumping and estimated recharge rates for 2005 and 2010. Flow paths from recharge at known contaminant source areas to discharge locations at wells or streams were simulated under steady-state conditions for the two periods. Simulated groundwater-flow paths shifted only slightly from 2005 to 2010 as a result of changes in pumping rates. These slight changes in groundwater-flow paths from known sources of contamination are not coincident with the spatial distribution of observed changes in TCE concentrations from 2005 to 2010, indicating that the decreases of TCE concentrations may be a result of other processes, such as source removal or degradation. Results of the simulations and the absence of increases in TCE-degradation-product concentrations indicate that the decreases of TCE concentrations observed in 2010 may be at least partly related to contaminant-source removal by soil excavation completed in 2005, although additional data would be needed to confirm this preliminary explanation.
Karatepe, Aslihan; Soylak, Mustafa; Elçi, Latif
2011-01-01
A new preconcentration method was developed for the determination of trace amounts of Cu(II), Fe(III), Pb(II), Ni(II), and Cd(II) on a double-walled carbon nanotube disk. 4-(2-Thiazolylazo) resorcinol was used as a complexing reagent. The effects of parameters, including pH of the solutions, amounts of complexing reagent, eluent type, sample volume, flow rates of solutions, and matrix ions were examined for quantitative recoveries of the studied analyte ions. The retained metal ions were eluted by 2 M HNO3. The LOD values for the analytes were in the range of 0.7-4.4 microg/mL. Natural water samples and standard reference materials were analyzed by the presented method.
NASA Astrophysics Data System (ADS)
Vasiliev, N. V.; Zeigarnik, Yu A.; Khodakov, K. A.
2017-11-01
Experimentally studying of subcooled water boiling in rectangular channel electrically heated from one side was conducted. Flat surfaces, both smooth and coated by microarc oxidation technology, were used as heating surfaces. The tests were conducted at atmospheric pressure in the range of mass flow rate from 650 to 1300 kg/(m2 s) and water subcooling relative to saturation temperature from 23 to 75 °C. Using high-speed filming a change in the two-phase flow structure and its statistic characteristics (nucleation sites density, vapor bubble distribution by size, etc.) were studied. With an increase in the heat flux density (with the mass flow rate and subcooling being the same) and amount and size of the vapor bubbles increased also. At a relatively high heat flux density, non-spherical vapor agglomerates appeared at the heating surface as a result of coalescence of small bubbles. They originated in chaotic manner in arbitrary points of the heating surface and then after random evolution in form and size collapsed. The agglomerate size reached several millimeters and their duration of life was several milliseconds. After formation of large vapor agglomerates, with a further small increase in heat flux density a burnout of the heating surface occurred. In most cases the same effect took place if the large agglomerates were retained for several minutes.
NASA Technical Reports Server (NTRS)
Omori, S.
1973-01-01
The turbulent kinetic energy equation is coupled with boundary layer equations to solve the characteristics of compressible turbulent boundary layers with mass injection and combustion. The Reynolds stress is related to the turbulent kinetic energy using the Prandtl-Wieghardt formulation. When a lean mixture of hydrogen and nitrogen is injected through a porous plate into the subsonic turbulent boundary layer of air flow and ignited by external means, the turbulent kinetic energy increases twice as much as that of noncombusting flow with the same mass injection rate of nitrogen. The magnitudes of eddy viscosity between combusting and noncombusting flows with injection, however, are almost the same due to temperature effects, while the distributions are different. The velocity profiles are significantly affected by combustion; that is, combustion alters the velocity profile as if the mass injection rate is increased, reducing the skin-friction as a result of a smaller velocity gradient at the wall. If pure hydrogen as a transpiration coolant is injected into a rocket nozzle boundary layer flow of combustion products, the temperature drops significantly across the boundary layer due to the high heat capacity of hydrogen. At a certain distance from the wall, hydrogen reacts with the combustion products, liberating an extensive amount of heat. The resulting large increase in temperature reduces the eddy viscosity in this region.
Numerical Simulation of Heat Transfer in Porous Metals for Cooling Applications
NASA Astrophysics Data System (ADS)
Gauna, Edgar Avalos; Zhao, Yuyuan
2017-08-01
Porous metals have low densities and novel physical, mechanical, thermal, electrical, and acoustic properties. Hence, they have attracted a large amount of interest over the last few decades. One of their applications is for thermal management in the electronics industry because of their fluid permeability and thermal conductivity. The heat transfer capability is achieved by the interaction between the internal channels within the porous metal and the coolant flowing through them. This paper studies the fluid flow and heat transfer in open-cell porous metals manufactured by space holder methods by numerical simulation using software ANSYS Fluent. A 3D geometric model of the porous structure was created based on the face-centered-cubic arrangement of spheres linked by cylinders. This model allows for different combinations of pore parameters including a wide range of porosity (50 to 80 pct), pore size (400 to 1000 µm), and metal particle size (10 to 75 µm). In this study, water was used as the coolant and copper was selected as the metal matrix. The flow rate was varied in the Darcian and Forchheimer's regimes. The permeability, form drag coefficient, and heat transfer coefficient were calculated under a range of conditions. The numerical results showed that permeability increased whereas the form drag coefficient decreased with porosity. Both permeability and form drag coefficient increased with pore size. Increasing flow rate and decreasing porosity led to better heat transfer performance.
Radiant extinction of gaseous diffusion flames
NASA Technical Reports Server (NTRS)
Atreya, Arvind; Agrawal, Sanjay; Shamim, Tariq; Pickett, Kent; Sacksteder, Kurt R.; Baum, Howard R.
1995-01-01
The absence of buoyancy-induced flows in microgravity significantly alters the fundamentals of many combustion processes. Substantial differences between normal-gravity and microgravity flames have been reported during droplet combustion, flame spread over solids, candle flames, and others. These differences are more basic than just in the visible flame shape. Longer residence time and higher concentration of combustion products create a thermochemical environment which changes the flame chemistry. Processes such as flame radiation, that are often ignored under normal gravity, become very important and sometimes even controlling. This is particularly true for conditions at extinction of a microgravity diffusion flame. Under normal-gravity, the buoyant flow, which may be characterized by the strain rate, assists the diffusion process to transport the fuel and oxidizer to the combustion zone and remove the hot combustion products from it. These are essential functions for the survival of the flame which needs fuel and oxidizer. Thus, as the strain rate is increased, the diffusion flame which is 'weak' (reduced burning rate per unit flame area) at low strain rates is initially 'strengthened' and eventually it may be 'blown-out'. Most of the previous research on diffusion flame extinction has been conducted at the high strain rate 'blow-off' limit. The literature substantially lacks information on low strain rate, radiation-induced, extinction of diffusion flames. At the low strain rates encountered in microgravity, flame radiation is enhanced due to: (1) build-up of combustion products in the flame zone which increases the gas radiation, and (2) low strain rates provide sufficient residence time for substantial amounts of soot to form which further increases the flame radiation. It is expected that this radiative heat loss will extinguish the already 'weak' diffusion flame under certain conditions. Identifying these conditions (ambient atmosphere, fuel flow rate, fuel type, etc.) is important for spacecraft fire safety. Thus, the objective is to experimentally and theoretically investigate the radiation-induced extinction of diffusion flames in microgravity and determine the effect of flame radiation on the 'weak' microgravity diffusion flame.
Reddy, Gudigopuram B; Raczkowski, Charles W; Cyrus, Johnsely S; Szogi, Ariel
2016-01-01
Constructed wetlands used for the treatment of swine wastewater may potentially sequester significant amounts of carbon. In past studies, we evaluated the treatment efficiency of wastewater in a marsh-pond-marsh design wetland system. The functionality of this system was highly dependent on soil carbon content and organic matter turnover rate. To better understand system performance and carbon dynamics, we measured plant dry matter, decomposition rates and soil carbon fractions. Plant litter decomposition rate was 0.0052 g day(-1) (±0.00119 g day(-1)) with an estimated half-life of 133 days. The detritus layer accumulated over the soil surface had much more humin than other C fractions. In marsh areas, soil C extracted with NaOH had four to six times higher amounts of humic acid, fulvic acid and humin than soil C extracted by cold and hot water, HCl/HF, and Na pyruvate. In the pond area, humic acid, fulvic acid and humin content were two to four times lower than in the marsh area. More soil C and N was found in the marsh area than in the pond area. These wetlands proved to be large sinks for stable C forms.
NASA Astrophysics Data System (ADS)
Khayat, Saed; Möller, Peter; Geyer, Stefan; Marei, Amer; Siebert, Christian; Hilo, Fayez Abu
2009-06-01
The spatial and temporal changes of the composition of the groundwater from the springs along the Wadi Qilt stream running from the Jerusalem-Ramallah Mountains towards the Jericho Plain is studied during the hydrological year 2006/2007. The residence time and the intensity of recharge play an important role in controlling the chemical composition of spring water which mainly depends on distance from the main recharge area. A very important factor is the oxidation of organics derived from sewage and garbage resulting in variable dissolved CO2 and associated HCO3 - concentration. High CO2 yields lower pH values and thus under-saturation with respect to calcite and dolomite. Low CO2 concentrations result in over-saturation. Only at the beginning and at the end of the rainy season calcite saturation is achieved. The degradation of dissolved organic matter is a major source for increasing water hardness. Besides dissolution of carbonates dissolved species such as nitrate, chloride, and sulfate are leached from soil and aquifer rocks together with only small amounts of Mg. Mg not only originates from carbonates but also from Mg-Cl waters are leached from aquifer rocks. Leaching of Mg-Cl brines is particularly high at the beginning of the winter season and lowest at its end. Two zones of recharge are distinguishable. Zone 1 represented by Ein Fara and Ein Qilt is fed directly through the infiltration of meteoric water and surface runoff from the mountains along the eastern mountain slopes with little groundwater residence time and high flow rate. The second zone is near the western border of Jericho at the foothills, which is mainly fed by the under-groundwater flow from the eastern slopes with low surface infiltration rate. This zone shows higher groundwater residence time and slower flow rate than zone 1. Groundwater residence time and the flow rate within the aquifer systems are controlled by the geological structure of the aquifer, the amount of active recharge to the aquifer, and the recharge mechanism. The results of this study may be useful in increasing the efficiency of freshwater exploitation in the region. Some precautions, however, should be taken in future plans of artificial recharge of the aquifers or surface-water harvesting in the Wadi. Because of evaporation and associated groundwater deterioration, the runoff water should be artificially infiltrated in zones of Wadis with high storage capacity of aquifers. Natural infiltration along the Wadis lead to evaporation losses and less quality of groundwater.
Accelerated uplift and magmatic intrusion of the Yellowstone caldera, 2004 to 2006
Chang, Wu-Lung; Smith, Robert B.; Wicks, Charles; Farrell, J.M.; Puskas, C.M.
2007-01-01
The Yellowstone caldera began a rapid episode of ground uplift in mid-2004, revealed by Global Positioning System and interferometric synthetic aperture radar measurements, at rates up to 7 centimeters per year, which is over three times faster than previously observed inflation rates. Source modeling of the deformation data suggests an expanding volcanic sill of ???1200 square kilometers at a 10-kilometer depth beneath the caldera, coincident with the top of a seismically imaged crustal magma chamber. The modeled rate of source volume increase is 0.1 cubic kilometer per year, similar to the amount of magma intrusion required to supply the observed high heat flow of the caldera. This evidence suggests magma recharge as the main mechanism for the accelerated uplift, although pressurization of magmatic fluids cannot be ruled out.
MUSCLE METABOLISM WITH BLOOD FLOW RESTRICTION IN CHRONIC FATIGUE SYNDROME
McCully, Kevin K.; Smith, Sinclair; Rajaei, Sheeva; Leigh, John S.; Natelson, Benjamin H.
2009-01-01
The purpose of this study was to determine if chronic fatigue syndrome (CFS) is associated with reduced blood flow and muscle oxidative metabolism. Patients with CFS according to CDC criteria (n=19) were compared to normal sedentary subjects (n = 11). Muscle blood flow was measured in the femoral artery with Doppler ultrasound after exercise. Muscle metabolism was measured in the medial gastrocnemius muscle using 31P magnetic resonance spectroscopy (MRS). Muscle oxygen saturation and blood volume were measured using near-infrared spectroscopy. CFS and controls were not different in hyperemic blood flow or phosphocreatine recovery rate. Cuff pressures of 50,60,70,80,and 90 mmHg were used to partially restrict blood flow during recovery. All pressures reduced blood flow and oxidative metabolism, with 90 mmHg reducing blood flow by 46% and oxidative metabolism by 30.7% in CFS patients. Hyperemic blood flow during partial cuff occlusion was significantly reduced in CFS patients (P < 0.01), and recovery of oxygen saturation was slower (P < 0.05). No differences were seen in the amount of reduction in metabolism with partially reduced blood flow. In conclusion, CFS patients showed evidence of reduced hyperemic flow and reduced oxygen delivery, but no evidence that this impaired muscle metabolism. Thus, CFS patients might have altered control of blood flow, but this is unlikely to influence muscle metabolism. Further, abnormalities in muscle metabolism do not appear to be responsible for the CFS symptoms. PMID:14578362
Ouf, Salama A; Basher, Abdulrahman H; Mohamed, Abdel-Aleam H
2015-12-01
Aspergillus niger has been reported as a potentially dangerous pathogen of date-palm fruits in Saudi Arabia due to the production of fumonisin B2 (FB2 ) and ochratoxin A (OTA). In a trial to disinfect this product, a double atmospheric pressure argon cold plasma (DAPACP) jet system was set up and evaluated against spore germination and mycotoxin production of the pathogen. The plasma jets were characterised photographically, electrically and spectroscopically. DAPACP jet length increases with the increase of argon flow rate, with optimum rate at 3.5 L min(-1) . The viability of A. niger spores, inoculated onto sterilised date palm fruit discs, progressively decreases with extension of the exposure time of DAPACP due to the more quantitative amount of OH and O radicals interacting with the examined samples. There was a progressive reduction of the amount of FB2 and OTA detected in date palm discs on extension of the exposure time of the plasma-treated inoculums at flow rate of 3.5 L min(-1) . FB2 was not detected in the discs inoculated with 6-min plasma-treated A. niger, while OTA was completely absent when the fungus was treated for 7.5 min. DAPACP showed promising results in dry fruit decontamination and in inhibition of mycotoxin release by A. niger contaminating the fruits. The progress in the commercial application of cold plasma needs further investigation concerning the ideal width of the plasma output to enable it to cover wider surfaces of the sample and consequently inducing greater plasma performance. © 2014 Society of Chemical Industry.
Catchment-scale groundwater recharge and vegetation water use efficiency
NASA Astrophysics Data System (ADS)
Troch, P. A. A.; Dwivedi, R.; Liu, T.; Meira, A.; Roy, T.; Valdés-Pineda, R.; Durcik, M.; Arciniega, S.; Brena-Naranjo, J. A.
2017-12-01
Precipitation undergoes a two-step partitioning when it falls on the land surface. At the land surface and in the shallow subsurface, rainfall or snowmelt can either runoff as infiltration/saturation excess or quick subsurface flow. The rest will be stored temporarily in the root zone. From the root zone, water can leave the catchment as evapotranspiration or percolate further and recharge deep storage (e.g. fractured bedrock aquifer). Quantifying the average amount of water that recharges deep storage and sustains low flows is extremely challenging, as we lack reliable methods to quantify this flux at the catchment scale. It was recently shown, however, that for semi-arid catchments in Mexico, an index of vegetation water use efficiency, i.e. the Horton index (HI), could predict deep storage dynamics. Here we test this finding using 247 MOPEX catchments across the conterminous US, including energy-limited catchments. Our results show that the observed HI is indeed a reliable predictor of deep storage dynamics in space and time. We further investigate whether the HI can also predict average recharge rates across the conterminous US. We find that the HI can reliably predict the average recharge rate, estimated from the 50th percentile flow of the flow duration curve. Our results compare favorably with estimates of average recharge rates from the US Geological Survey. Previous research has shown that HI can be reliably estimated based on aridity index, mean slope and mean elevation of a catchment (Voepel et al., 2011). We recalibrated Voepel's model and used it to predict the HI for our 247 catchments. We then used these predicted values of the HI to estimate average recharge rates for our catchments, and compared them with those estimated from observed HI. We find that the accuracies of our predictions based on observed and predicted HI are similar. This provides an estimation method of catchment-scale average recharge rates based on easily derived catchment characteristics, such as climate and topography, and free of discharge measurements.
Bi-Component Droplet Combustion in Reduced Gravity
NASA Technical Reports Server (NTRS)
Shaw, Benjamin D.
2004-01-01
This research deals with reduced-gravity combustion of bi-component droplets initially in the mm size range or larger. The primary objectives of the research are to study the effects of droplet internal flows, thermal and solutal Marangoni stresses, and species volatility differences on liquid species transport and overall combustion phenomena (e.g., gas-phase unsteadiness, burning rates, sooting, radiation, and extinction). The research program utilizes a reduced gravity environment so that buoyancy effects are rendered negligible. Use of large droplets also facilitates visualization of droplet internal flows, which is important for this research. In the experiments, droplets composed of low- and high-volatility species are burned. The low-volatility components are initially present in small amounts. As combustion of a droplet proceeds, the liquid surface mass fraction of the low-volatility component will increase with time, resulting in a sudden and temporary decrease in droplet burning rates as the droplet rapidly heats to temperatures close to the boiling point of the low-volatility component. This decrease in burning rates causes a sudden and temporary contraction of the flame. The decrease in burning rates and the flame contraction can be observed experimentally. Measurements of burning rates as well as the onset time for flame contraction allow effective liquid-phase species diffusivities to be calculated, e.g., using asymptotic theory. It is planned that droplet internal flows will be visualized in flight and ground-based experiments. In this way, effective liquid species diffusivities can be related to droplet internal flow characteristics. This program is a continuation of extensive ground-based experimental and theoretical research on bi-component droplet combustion that has been ongoing for several years. The focal point of this program is a flight experiment (Bi-Component Droplet Combustion Experiment, BCDCE). This flight experiment is under development. However, supporting ground-based studies have been performed. Some of the most recent ground-based research is summarized.
Bi-Component Droplet Combustion in Reduced Gravity
NASA Technical Reports Server (NTRS)
Shaw, B. D.
2001-01-01
This research deals with reduced-gravity combustion of bi-component droplets initially in the mm size range or larger. The primary objectives of the research are to study the effects of droplet internal flows, thermal and solutal Marangoni stresses, and species volatility differences on liquid species transport and overall combustion phenomena (e.g., gas-phase unsteadiness, burning rates, sooting, radiation, and extinction). The research program utilizes a reduced-gravity environment so that buoyancy effects are rendered negligible. Use of large droplets also facilitates visualization of droplet internal flows, which is important for this research. In the experiments, droplets composed of low- and high-volatility species are burned. The low-volatility components are initially present in small amounts. As combustion of a droplet proceeds, the liquid surface mass fraction of the low-volatility component will increase with time, resulting in a sudden and temporary decrease in droplet burning rates as the droplet rapidly heats to temperatures close to the boiling point of the low-volatility component. This decrease in burning rates causes a sudden and temporary contraction of the flame. The decrease in burning rates and the flame contraction can be observed experimentally. Measurements of burning rates as well as the onset time for flame contraction allow effective liquid-phase species diffusivities to be calculated, e.g., using asymptotic theory. It is planned that droplet internal flows will be visualized in future flight and ground-based experiments. In this way, effective liquid species diffusivities can be related to droplet internal flow characteristics. This program is a continuation of extensive ground based experimental and theoretical research on bi-component droplet combustion that has been ongoing for several years. The focal point of this program is a flight experiment (Bi-Component Droplet Combustion Experiment, BCDCE). This flight experiment is under development. However, supporting studies have been performed. Because of space limitations, only some of the research performed over the last two years (since the 5th Microgravity Combustion Workshop) is summarized here.
Grotti, Marco; Abelmoschi, Maria Luisa; Soggia, Francesco; Frache, Roberto
2003-01-01
A study was carried out on the preconcentration of ultratrace amounts of cadmium, lead, manganese, copper and iron from high-salinity aqueous samples and determination by atomic spectrometry methods. Sample volume, amount of resin, loading flow rate, and elution volume were optimized in order to obtain the simultaneous preconcentration of all the analytes. Quantitative recoveries were obtained by using 200 mg of iminodiacetic resin with a loading flow rate of 2 mL min(-1), elution volume of 3 mL and sample volume of 50-450 mL. Only copper in seawater samples was not completely retained by the resin (60-70% recovery), due to unfavorable competition of iminodiacetic-active groups with organically bound metal.To quantify the metals in the eluates, two atomic spectrometry techniques were compared: electrothermal atomization atomic absorption spectrometry (ETAAS) and inductively coupled plasma-optical emission spectrometry (ICP-OES) with simultaneous CCD detection system. Both techniques are suitable for sample analysis with detection limits of 1.0, 4.7, 3.3, 6.8, and 53 ng L(-1) using ETAAS and 12, 122, 3.4, 17, and 21 ng L(-1) using ICP-OES for Cd, Pb, Mn, Cu, and Fe, respectively. Relative standard deviations of the procedures ranged from 1.7 to 14% at the sub-microg L(-1) concentration level. The accuracy of both methods was verified by analyzing various certified reference materials (river water, estuarine water, coastal and off-shore seawater).
Caries and salivary status in young adults with type 1 diabetes.
Edblad, E; Lundin, S A; Sjödin, B; Aman, J
2001-01-01
The aim of this study was to evaluate the salivary status, prevalence of caries and the status of primary dentition, when primary teeth were exfoliated, in 41 patients, 18-24 years of age, with type 1 diabetes since childhood in comparison with age- and sex-matched non-diabetic controls. The blood glucose and glycosylated haemoglobin concentration (HbA1c), dosage of daily insulin and retinal fundus photography was recorded for the diabetic group. According to the concentration of HbA1c, the diabetic patients were divided into well and poorly controlled groups. The study was based on three intra-oral photos, dental examination including intra-oral radiographs, flow rate and buffering capacity of the saliva and amount of Streptococcus mutans and Lactobacilli. Retrospective data regarding the primary dentition was found in the dental files of each patient, and are based on the last registration for respective tooth before exfoliation. The patients with type 1 diabetes, without any relationship to metabolic control, displayed more initial buccal caries compared to healthy controls (p<0.01). No significant differences concerning the status of saliva (neither flow rate, buffering capacity nor amount of Streptococcus mutans and Lactobacilli), manifest caries or the status of the primary dentition were seen. We conclude that initial, but not manifest caries seems to be overrepresented in young adults with type 1 diabetes. These patients, thus, need more intense efforts regarding dental health care to prevent the development from initial to manifest caries.
NASA Astrophysics Data System (ADS)
Korman, Josh
2010-05-01
The abundance of adult fish populations is controlled by the growth and survival rates of early life stages. Evaluating the effects of flow regimes on early life stages is therefore critical to determine how these regimes affect the abundance of adult populations. Experimental high flow releases from Glen Canyon Dam, primarily intended to conserve fine sediment and improve habitat conditions for native fish in the Colorado River in Grand Canyon, AZ, have been conducted in 1996, 2004, and 2008. These flows potentially affect the Lee's Ferry reach rainbow trout population, located immediately downstream of the dam, which supports a highly valued fishery and likely influences the abundance of rainbow trout in Grand Canyon. Due to concerns about negative effects of high trout abundance on endangered native fish, hourly variation in flow from Glen Canyon Dam was experimentally increased between 2003 and 2005 to reduce trout abundance. This study reports on the effects of experimental high flow releases and fluctuating flows on early life stages of rainbow trout in the Lee's Ferry reach based on monthly sampling of redds (egg nests) and the abundance and growth of age-0 trout between 2003 and 2009. Data on spawn timing, spawning elevations, and intergravel temperatures were integrated in a model to estimate the magnitude and seasonal trend in incubation mortality resulting from redd dewatering due to fluctuations in flow. Experimental fluctuations from January through March promoted spawning at higher elevations where the duration of dewatering was longer and intergravel temperatures exceeded lethal thresholds. Flow-dependent incubation mortality rates were 24% (2003) and 50% (2004) in years with higher flow fluctuations, compared to 5-11% under normal operations (2006-2009). Spatial and temporal predictions of mortality were consistent with direct observations of egg mortality determined from the excavation of 125 redds. The amount of variation in backcalculated hatch date distributions predicted by flow-independent (84-93%) and flow-dependent (82-91%) incubation loss models were similar. Age-0 abundance was generally independent of viable egg deposition, except in one year when egg deposition was 10-fold lower due to reduced spawning activity. There was no evidence from the hatch date or stock-recruitment analysis that flow-dependent incubation losses, although large in experimental years, affected the abundance of the age-0 population. The data indicate that strong compensation in survival rates shortly after emergence mitigated the impact of flow-dependent losses. Multiple lines of evidence demonstrated that the March 2008 high flow experiment (HFE) resulted in a large increase in early survival rates (fertilization to ~1-2 months from emergence) of age-0 trout due an improvement in habitat conditions. A stock-recruitment analysis indicated that age-0 abundance in July 2008 was over four-fold higher than expected given the number of viable redds that produced these fish. A hatch date analysis indicated that early survival rates were much higher for cohorts that emerged about two months after the HFE. These cohorts, which were fertilized after the HFE, were not exposed to high flows and emerged into better quality habitat. Inter annual differences in growth of age-0 trout based on otolith microstructure support this hypothesis. Growth rates in the summer and fall of 2008 (0.44 mm·day-1) were virtually the same as in 2006 (0.46 mm·day-1), the highest recorded over six years, even though abundance was eight-fold greater in 2008. I speculate that high flows in 2008 increased interstitial spaces in the substrate and food availability or quality, leading to higher early survival of recently emerged trout and better growth during summer and fall. Abundance in 2009 was over two-fold higher than expected, possibly indicating that the effect of the HFE on early life stages was somewhat persistent.
Vraníková, Barbora; Gajdziok, Jan; Doležel, Petr
2017-03-01
The preparation of liquisolid systems (LSS) represents a promising method for enhancing a dissolution rate and bioavailability of poorly soluble drugs. The release of the drug from LSS tablets is affected by many factors, including the disintegration time. The evaluation of differences among LSS containing varying amounts and types of commercially used superdisintegrants (Kollidon® CL-F, Vivasol® and Explotab®). LSS were prepared by spraying rosuvastatin solution onto Neusilin® US2 and further processing into tablets. Varying amounts of superdisintegrants were used and the differences among LSS were evaluated. The multiple scatter plot method was used to visualize the relationships within the obtained data. All disintegrants do not showed negative effect on the flow properties of powder blends. The type and concentration of superdisintegrant had an impact on the disintegration time and dissolution profiles of tablets. Tablets with Explotab® showed the longest disintegration time and the smallest amount of released drug. Fastest disintegration and dissolution rate were observed in tablets containing Kollidon® CL-F (≥2.5% w/w). Also tablets with Vivasol® (2.5-4.0% w/w) showed fast disintegration and complete drug release. Kollidon® CL-F and Vivasol® in concentration ≥2.5% are suitable superdisintegrants for LSS with enhanced release of drug.
Jerković, Igor; Molnar, Maja; Vidović, Senka; Vladić, Jelena; Jokić, Stela
2017-11-01
Lavandula angustifolia is good source of oxygenated monoterpenes containing coumarins as well, which are all soluble in supercritical CO 2 (SC-CO 2 ). The study objective is to investigate SC-CO 2 extraction parameters on: the total yield; GC-MS profile of the extracts; relative content of oxygenated monoterpenes; the amount of coumarin and herniarin; and to determine optimal SC-CO 2 extraction conditions by response surface methodology (RSM). SC-CO 2 extraction was performed under different pressure, temperature and CO 2 flow rate determined by Box-Behnken design (BBD). The sample mass and the extraction time were kept constant. The chemical profiles and relative content of oxygenated monoterpenes (as coumarin equivalents, CE) were determined by GC-MS. Coumarin and herniarin concentrations were dosed by HPLC. SC-CO 2 extracts contained linalool (57.4-217.9 mg CE/100 g), camphor (10.6-154.4 mg CE/100 g), borneol (6.2-99.9 mg CE/100 g), 1,8-cineole (5.0-70.4 mg CE/100 g), linalyl acetate (86.1-267.9 mg CE/100 g), coumarin (0.95-18.16 mg/100 g), and herniarin (0.95-13.63 mg/100 g). The interaction between the pressure and CO 2 flow rate as well as between the temperature and CO 2 flow rate showed statistically significant influence on the extraction yield. Applying BBD, the optimum extraction conditions for higher monoterpenes and lower coumarin content were at 10 MPa, 41°C and CO 2 flow rate 2.3 kg/h, and at 30 MPa, 50°C and CO 2 flow rate 3 kg/h for higher monoterpenes and coumarin content. SC-CO 2 extraction is a viable technique for obtaining lavender extracts with desirable flavour components. The second-order model based on BBD predicts the results for SC-CO 2 extraction quite satisfactorily. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Crushed cement concrete substitution for construction aggregates; a materials flow analysis
Kelly, Thomas
1998-01-01
An analysis of the substitution of crushed cement concrete for natural construction aggregates is performed by using a materials flow diagram that tracks all material flows into and out of the cement concrete portion of the products made with cement concrete: highways, roads, and buildings. Crushed cement concrete is only one of the materials flowing into these products, and the amount of crushed cement concrete substituted influences the amount of other materials in the flow. Factors such as availability and transportation costs, as well as physical properties, that can affect stability and finishability, influence whether crushed cement concrete or construction aggregates should be used or predominate for a particular end use.
Evaluating the economic viability of a material recovery system: the case of cathode ray tube glass.
Gregory, Jeremy R; Nadeau, Marie-Claude; Kirchain, Randolph E
2009-12-15
This paper presents an analysis of the material recovery system for leaded glass from cathode ray tubes (CRTs) using a dynamic material flow analysis. In particular, the global mass flow of primary and secondary CRT glass and the theoretical capacities for using secondary CRT glass to make new CRT glass are analyzed. The global mass flow analysis indicates that the amount of new glass required is decreasing, but is much greater than the amount of secondary glass collected, which is increasing. The comparison of the ratio of secondary glass collected to the amount of new glass required from the mass flow analysis indicates that the material recovery system is sustainable for the foreseeable future. However, a prediction of the time at which the market for secondary glass will collapse due to excess capacity is not possible at the moment due to several sources of uncertainty.
NASA Technical Reports Server (NTRS)
Magee-Roberts, K.; Head, James W., III; Lancaster, M. G.
1992-01-01
Large-volume lava flow fields have been identified on Venus, the most areally extensive of which are known as fluctus and have been subdivided into six morphologic types. Sheetlike flow fields (Type 1) lack the numerous, closely spaced, discrete lava flow lobes that characterize digitate flow fields. Transitional flow fields (Type 2) are similar to sheetlike flow fields but contain one or more broad flow lobes. Digitate flow fields are divided further into divergent (Types 3-5) and subparallel (Type 6) classes on the basis of variations in the amount of downstream flow divergence. As a result of our previous analysis of the detailed morphology, stratigraphy, and tectonic associations of Mylitta Fluctus, we have formulated a number of questions to apply to all large flow fields on Venus. In particular, we would like to address the following: (1) eruption conditions and style of flow emplacement (effusion rate, eruption duration), (2) the nature of magma storage zones (presence of neutral buoyancy zones, deep or shallow crustal magma chambers), (3) the origin of melt and possible link to mantle plumes, and (4) the importance of large flow fields in plains evolution. To answer these questions we have begun to examine variations in flow field dimension and morphology; the distribution of large flow fields in terms of elevation above the mean planetary radius; links to regional tectonic or volcanic structures (e.g., associations with large shield edifices, coronae, or rift zones); statigraphic relationships between large flow fields, volcanic plains, shields, and coronae; and various models of flow emplacement in order to estimate eruption parameters. In this particular study, we have examined the proximal elevations and topographic slopes of 16 of the most distinctive flow fields that represent each of the 6 morphologic types.
Miranda-Fuentes, Antonio; Rodríguez-Lizana, Antonio; Gil, Emilio; Agüera-Vega, J; Gil-Ribes, Jesús A
2015-12-15
Olive is a key crop in Europe, especially in countries around the Mediterranean Basin. Optimising the parameters of a spray is essential for sustainable pesticide use, especially in high-input systems, such as the super-intensive hedgerow system. Parameters may be optimised by adjusting the applied volume and airflow rate of sprays, in addition to the liquid to air proportion and the relationship between air velocity and airflow rate. Two spray experiments using a commercial airblast sprayer were conducted in a super-intensive orchard to study how varying the liquid volume rate (testing volumes of 182, 619, and 1603 l ha(-1)) and volumetric airflow rate (with flow rates of 11.93, 8.90, and 6.15 m(3) s(-1)) influences the coverage parameters and the amount and distribution of deposits in different zones of the canopy.. Our results showed that an increase in the application volume raised the mean deposit and percentage coverage, but decreased the application efficiency, spray penetration, and deposit homogeneity. Furthermore, we found that the volumetric airflow rate had a lower influence on the studied parameters than the liquid volume; however, an increase in the airflow rate improved the application efficiency and homogeneity to a certain threshold, after which the spray quality decreased. This decrease was observed in the high-flow treatment. Our results demonstrate that intermediate liquid volume rates and volumetric airflow rates are required for the optimal spraying of pesticides on super-intensive olive crops, and would reduce current pollution levels. Copyright © 2015 Elsevier B.V. All rights reserved.
Inspiratory Tube Condensation During High-Flow Nasal Cannula Therapy: A Bench Study.
Chikata, Yusuke; Unai, Kazuaki; Izawa, Masayo; Okuda, Nao; Oto, Jun; Nishimura, Masaji
2016-03-01
High-flow nasal cannula (HFNC) therapy provides better humidification than conventional oxygen therapy. To allay loss of vapor as condensation, a servo-controlled heating wire is incorporated in the inspiratory tube, but condensation is not completely avoidable. We investigated factors that might affect condensation: thermal characteristics of the inspiratory tube, HFNC flow, and ambient temperature. We evaluated 2 types of HFNC tubes, SLH Flex 22-mm single tube and RT202. Both tubes were connected to a heated humidifier with water reservoir. HFNC flow was set at 20, 40, and 60 L/min, and FIO2 was set at 0.21. Air conditioning was used maintain ambient temperature at close to either 20 or 25°C. We weighed the tubes on a digital scale before (0 h) and at 3, 6, and 24 h after, turning on the heated humidifier, and calculated the amount of condensation by simple subtraction. The amount of distilled water used during 24 h was also recorded. At 25°C, there was little condensation, but at 20°C and HFNC flow of 20, 40, and 60 L/min for 24 h, the amount of condensation with the SLH was 50.2 ± 10.7, 44.3 ± 17.7, and 56.6 ± 13.9 mg, and the amount with the RT202 was 96.0 ± 35.1, 72.8 ± 8.2, and 64.9 ± 0.8 mg. When ambient temperature was set to 20°C, condensation with the RT202 was statistically significantly greater than with the SLH at all flow settings (P < .001). Ambient temperature statistically significantly influenced the amount of condensation in the tubes. Copyright © 2016 by Daedalus Enterprises.
Separation of Lead from Crude Antimony by Pyro-Refining Process with NaPO3 Addition
NASA Astrophysics Data System (ADS)
Ye, Longgang; Hu, Yuejie; Xia, Zhimei; Chen, Yongming
2016-06-01
The main purpose of this study was to separate lead from crude antimony through an oxidation pyro-refining process and by using sodium metaphosphate as a lead elimination reagent. The process parameters that will affect the refining results were optimized experimentally under controlled conditions, such as the sodium metaphosphate charging dosage, the refining temperature and duration, and the air flow rate, to determine their effect on the lead content in refined antimony and the lead removal rate. A minimum lead content of 0.0522 wt.% and a 98.6% lead removal rate were obtained under the following optimal conditions: W_{{{NaPO}_{{3}} }} = 15% W Sb (where W represents weight), a refining temperature of 800°C, a refining time of 30 min, and an air flow rate of 3 L/min. X-ray diffractometry and scanning electron microscopy showed that high-purity antimony was obtained. The smelting operation is free from smoke or ammonia pollution when using monobasic sodium phosphate or ammonium dihydrogen phosphate as the lead elimination reagent. However, this refining process can also remove a certain amount of sulfur, cobalt, and silicon simultaneously, and smelting results also suggest that sodium metaphosphate can be used as a potential lead elimination reagent for bismuth and copper refining.
Sacha, Gregory A; Schmitt, William J; Nail, Steven L
2006-01-01
The critical processing parameters affecting average particle size, particle size distribution, yield, and level of residual carrier solvent using the supercritical anti-solvent method (SAS) were identified. Carbon dioxide was used as the supercritical fluid. Methylprednisolone acetate was used as the model solute in tetrahydrofuran. Parameters examined included pressure of the supercritical fluid, agitation rate, feed solution flow rate, impeller diameter, and nozzle design. Pressure was identified as the most important process parameter affecting average particle size, either through the effect of pressure on dispersion of the feed solution into the precipitation vessel or through the effect of pressure on solubility of drug in the CO2/organic solvent mixture. Agitation rate, impeller diameter, feed solution flow rate, and nozzle design had significant effects on particle size, which suggests that dispersion of the feed solution is important. Crimped HPLC tubing was the most effective method of introducing feed solution into the precipitation vessel, largely because it resulted in the least amount of clogging during the precipitation. Yields of 82% or greater were consistently produced and were not affected by the processing variables. Similarly, the level of residual solvent was independent of the processing variables and was present at 0.0002% wt/wt THF or less.
NEUTRONIC REACTOR CORE INSTRUMENT
Mims, L.S.
1961-08-22
A multi-purpose instrument for measuring neutron flux, coolant flow rate, and coolant temperature in a nuclear reactor is described. The device consists essentially of a hollow thimble containing a heat conducting element protruding from the inner wall, the element containing on its innermost end an amount of fissionsble materinl to function as a heat source when subjected to neutron flux irradiation. Thermocouple type temperature sensing means are placed on the heat conducting element adjacent the fissionable material and at a point spaced therefrom, and at a point on the thimble which is in contact with the coolant fluid. The temperature differentials measured between the thermocouples are determinative of the neutron flux, coolant flow, and temperature being measured. The device may be utilized as a probe or may be incorporated in a reactor core. (AE C)
The metabolic regimes of flowing waters
Bernhardt, Emily S.; Heffernan, Jim B.; Grimm, Nancy B.; Stanley, Emily H.; Harvey, Judson; Arroita, M.; Appling, Alison; Cohen, M.J.; McDowell, William H.; Hall, R.O.; Read, Jordan S.; Roberts, B.J.; Stets, Edward; Yackulic, Charles B.
2018-01-01
The processes and biomass that characterize any ecosystem are fundamentally constrained by the total amount of energy that is either fixed within or delivered across its boundaries. Ultimately, ecosystems may be understood and classified by their rates of total and net productivity and by the seasonal patterns of photosynthesis and respiration. Such understanding is well developed for terrestrial and lentic ecosystems but our understanding of ecosystem phenology has lagged well behind for rivers. The proliferation of reliable and inexpensive sensors for monitoring dissolved oxygen and carbon dioxide is underpinning a revolution in our understanding of the ecosystem energetics of rivers. Here, we synthesize our current understanding of the drivers and constraints on river metabolism, and set out a research agenda aimed at characterizing, classifying and modeling the current and future metabolic regimes of flowing waters.
Design and evaluation of a flow-to-frequency converter circuit with thermal feedback
NASA Astrophysics Data System (ADS)
Pawlowski, Eligiusz
2017-05-01
A novel thermal flow sensor with a frequency output is presented. The sensor provides a pulse-train output whose frequency is related to the fluid flow rate around a self-heating thermistor. The integrating properties of the temperature sensor have been used, which allowed for realization of the pulse frequency modulator with a thermal feedback loop, stabilizing the temperature of the sensor placed in the flowing medium. The system assures a balance of the amount of heat supplied in the impulses to the sensor and the heat given up by the sensor in a continuous way to the flowing medium. Therefore the frequency of output pulse-train is proportional to the medium flow velocity around the sensor. The special feature of the presented solution is the total integration of the thermal sensor with the measurement signal conditioning system. i.e. the sensor and conditioning system are not separate elements of the measurement circuit, but constitute a whole in the form of a thermal heat-balance mode flow-to-frequency converter. The frequency signal from the converter may be directly connected to the microprocessor digital input, which with use of the standard built-in counters may convert the frequency into a numerical value of high precision. The sensor has been experimentally characterized as a function of the average flow velocity of air at room temperature.
Emission Spectroscopy and Radiometric Measurements in the NASA Ames IHF Arc Jet Facility
NASA Technical Reports Server (NTRS)
Winter, Michael W.; Raiche, George A.; Prabhu, Dinesh K.
2012-01-01
Plasma diagnostic measurement campaigns in the NASA Ames Interaction Heating Facility (IHF) have been conducted over the last several years with a view towards characterizing the flow in the arc jet facility by providing data necessary for modeling and simulation. Optical emission spectroscopy has been used in the plenum and in the free jet of the nozzle. Radiation incident over a probe surface has also been measured using radiometry. Plenum measurements have shown distinct radial profiles of temperature over a range of operating conditions. For cases where large amounts of cold air are added radially to the main arc-heated stream, the temperature profiles are higher by as much as 1500 K than the profiles assumed in flow simulations. Optical measurements perpendicular to the flow direction in the free jet showed significant contributions to the molecule emission through inverse pre-dissociation, thus allowing determination of atom number densities from molecular emission. This has been preliminarily demonstrated with the N2 1st Positive System. Despite the use of older rate coefficients, the resulting atom densities are reasonable and surprisingly close to flow predictions.
Kiba, Nobutoshi; Ito, Seiji; Tachibana, Masaki; Tani, Kazue; Koizumi, Hitoshi
2003-12-01
A detector for the simultaneous determination of choline (Ch) and acetylcholine (ACh) based on a sensitive trienzyme chemiluminometric biosensor in a single line flow injection (FI) system is described. Immobilized choline oxidase (ChOx), immobilized peroxidase (POx), immobilized acetylcholinesterase, and coimmobilized ChOx/POx were packed, in turn, in a transparent ETFE tube (1 mm i.d., 75 cm) and the tube was placed in front of a photomultipier tube as a flow cell. Two-peak response was obtained by one injection of the sample solution. The first and second peaks were dependent on the concentrations of Ch and ACh, respectively. The influence of some experimental parameters such as flow rate, amounts of immobilized enzymes on the behavior of the sensor was studied in order to optimize the sensitivity, sample throughput and resolution. Calibration curves were linear at 1 - 1000 nM for Ch and 3 - 3000 nM for ACh. The sample throughput was 25/h without carryover. The FI system was applied to the simultaneous determination of Ch and ACh in rabbit brain tissue homogenates.
Chemically generated convective transport in microfluidic system
NASA Astrophysics Data System (ADS)
Shklyaev, Oleg; Das, Sambeeta; Altemose, Alicia; Shum, Henry; Balazs, Anna; Sen, Ayusman
High precision manipulation of small volumes of fluid, containing suspended micron sized objects like cells, viruses, and large molecules, is one of the main goals in designing modern lab-on-a-chip devices which can find a variety of chemical and biological applications. To transport the cargo toward sensing elements, typical microfluidic devices often use pressure driven flows. Here, we propose to use enzymatic chemical reactions which decompose reagent into less dense products and generate flows that can transport particles. Density variations that lead to flow in the assigned direction are created between the place where reagent is fed into the solution and the location where it is decomposed by enzymes attached to the surface of the microchannel. When the reagent is depleted, the fluid motion stops and particles sediment to the bottom. We demonstrate how the choice of chemicals, leading to specific reaction rates, can affect the transport properties. In particular, we show that the intensity of the fluid flow, the final location of cargo, and the time for cargo delivery are controlled by the amount and type of reagent in the system.
A Thermally-Regenerative Ammonia-Based Flow Battery for Electrical Energy Recovery from Waste Heat.
Zhu, Xiuping; Rahimi, Mohammad; Gorski, Christopher A; Logan, Bruce
2016-04-21
Large amounts of low-grade waste heat (temperatures <130 °C) are released during many industrial, geothermal, and solar-based processes. Using thermally-regenerative ammonia solutions, low-grade thermal energy can be converted to electricity in battery systems. To improve reactor efficiency, a compact, ammonia-based flow battery (AFB) was developed and tested at different solution concentrations, flow rates, cell pairs, and circuit connections. The AFB achieved a maximum power density of 45 W m(-2) (15 kW m(-3) ) and an energy density of 1260 Wh manolyte (-3) , with a thermal energy efficiency of 0.7 % (5 % relative to the Carnot efficiency). The power and energy densities of the AFB were greater than those previously reported for thermoelectrochemical and salinity-gradient technologies, and the voltage or current could be increased using stacked cells. These results demonstrated that an ammonia-based flow battery is a promising technology to convert low-grade thermal energy to electricity. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Transonic flow of steam with non-equilibrium and homogenous condensation
NASA Astrophysics Data System (ADS)
Virk, Akashdeep Singh; Rusak, Zvi
2017-11-01
A small-disturbance model for studying the physical behavior of a steady transonic flow of steam with non-equilibrium and homogeneous condensation around a thin airfoil is derived. The steam thermodynamic behavior is described by van der Waals equation of state. The water condensation rate is calculated according to classical nucleation and droplet growth models. The current study is based on an asymptotic analysis of the fluid flow and condensation equations and boundary conditions in terms of the small thickness of the airfoil, small angle of attack, closeness of upstream flow Mach number to unity and small amount of condensate. The asymptotic analysis gives the similarity parameters that govern the problem. The flow field may be described by a non-homogeneous transonic small-disturbance equation coupled with a set of four ordinary differential equations for the calculation of the condensate mass fraction. An iterative numerical scheme which combines Murman & Cole's (1971) method with Simpson's integration rule is applied to solve the coupled system of equations. The model is used to study the effects of energy release from condensation on the aerodynamic performance of airfoils operating at high pressures and temperatures and near the vapor-liquid saturation conditions.
Foliar water uptake of Tamarix ramosissima from an atmosphere of high humidity.
Li, Shuang; Xiao, Hong-lang; Zhao, Liang; Zhou, Mao-Xian; Wang, Fang
2014-01-01
Many species have been found to be capable of foliar water uptake, but little research has focused on this in desert plants. Tamarix ramosissima was investigated to determine whether its leaves can directly absorb water from high humidity atmosphere and, if they can, to understand the magnitude and importance of foliar water uptake. Various techniques were adopted to demonstrate foliar water uptake under submergence or high atmospheric humidity. The mean increase in leaf water content after submergence was 29.38% and 20.93% for mature and tender leaves, respectively. In the chamber experiment, obvious reverse sap flow occurred when relative humidity (RH) was persistently above 90%. Reverse flow was recorded first in twigs, then in branches and stems. For the stem, the percentage of negative sap flow rate accounting for the maximum value of sap flow reached 10.71%, and its amount accounted for 7.54% of diurnal sap flow. Small rainfall can not only compensate water loss of plant by foliar uptake, but also suppress transpiration. Foliar uptake can appear in the daytime under certain rainfall events. High atmospheric humidity is beneficial for enhancing the water status of plants. Foliar uptake should be an important strategy of water acquisition for desert plants.
Suction performance and internal flow of a 2-bladed helical inducer with inlet asymmetric plate
NASA Astrophysics Data System (ADS)
Watanabe, S.; Uchinono, Y.; Ishizaka, K.; Furukawa, A.; Kim, J.-H.
2013-10-01
It has been found in our past studies that the installation of asymmetric plate at the inlet of inducer is effective for the suppression of cavitation surge phenomenon. In the present study, the suction performance of 2-bladed helical inducer with an inlet asymmetric plate is experimentally investigated. It is observed that the suction performance in large flow rate conditions is not significantly influenced by the asymmetric plate, whereas the head of inducer with the asymmetric plate increases just before the head breakdown in partial flow conditions. To understand the mechanism of this additional head, the flow measurements and the numerical simulations are carried out. It is found that the circumferential component of absolute velocity at the exit of inducer slightly increases with the development of cavitation in both cases with and without the inlet asymmetric plate, indicating the increase of the theoretical head. The theoretical head increase with the inlet asymmetric plate is also confirmed by the unsteady numerical simulations, suggesting that the additional head is achieved through the increase of the theoretical head with the change of the exiting flow from the inducer associated with some amount of cavitation.
NASA Astrophysics Data System (ADS)
Kireev, Victor; Kovaleva, Liana; Isakov, Andrey; Alimbekova, Sofya
2017-11-01
In the present paper, an attempt to explain the mechanisms of the electromagnetic field influence on the process of formation and deposition of calcium carbonate from supersaturated brine solution has been made using numerical modeling. The one-dimensional mathematical model of the brine laminar flow through a cylindrical tube with non-uniform temperature field is written in the form of the system of transient convection-diffusion-reaction partial differential equations describing temperature field and chemical components concentrations (Ca2+, HCO3-, CaCO3). The influence of the temperature on the kinetics of formation of calcium carbonate is taken into account and it is described in accordance with the Arrhenius equation. The kinetics of the calcium carbonate precipitation on the wall of the pipe is given on the basis of the Henry isotherm. It has been established that the electromagnetic treatment of brine solution leads to a decrease of the adsorption rate constant and Henry's constant but it does not significantly influence on the chemical reaction rate of calcium carbonate formation. It also has been shown that treatment with electromagnetic field significantly reduces the amount of calcium carbonate deposits on the wall of the pipe.
Roh, Changhyun; Lee, Jaewoong; Kang, Chankyu
2016-06-18
Experimental investigations were conducted to determine the influence of polydimethylsiloxane (PDMS) microfluidic channels containing aligned circular obstacles (with diameters of 172 µm and 132 µm) on the flow velocity and pressure drop under steady-state flow conditions. A significant PDMS bulging was observed when the fluid flow initially contacted the obstacles, but this phenomenon decreased in the 1 mm length of the microfluidic channels when the flow reached a steady-state. This implies that a microfluidic device operating with steady-state flows does not provide fully reliable information, even though less PDMS bulging is observed compared to quasi steady-state flow. Numerical analysis of PDMS bulging using ANSYS Workbench showed a relatively good agreement with the measured data. To verify the influence of PDMS bulging on the pressure drop and flow velocity, theoretical analyses were performed and the results were compared with the experimental results. The measured flow velocity and pressure drop data relatively matched well with the classical prediction under certain circumstances. However, discrepancies were generated and became worse as the microfluidic devices were operated under the following conditions: (1) restricted geometry of the microfluidic channels (i.e., shallow channel height, large diameter of obstacles and a short microchannel length); (2) operation in quasi-steady state flow; (3) increasing flow rates; and (4) decreasing amount of curing agent in the PDMS mixture. Therefore, in order to obtain reliable data a microfluidic device must be operated under appropriate conditions.
Open vs Laparoscopic Simple Prostatectomy: A Comparison of Initial Outcomes and Cost.
Demir, Aslan; Günseren, Kadir Ömür; Kordan, Yakup; Yavaşçaoğlu, İsmet; Vuruşkan, Berna Aytaç; Vuruşkan, Hakan
2016-08-01
We compared the cost-effectiveness of laparoscopic simple prostatectomy (LSP) vs open prostatectomy (OP). A total of 73 men treated for benign prostatic hyperplasia were enrolled for OP and LSP in groups 1 and 2, respectively. The findings were recorded perioperative, including operation time (OT), blood lost, transfusion rate, conversion to the open surgery, and the complications according to the Clavien Classification. The postoperative findings, including catheterization and drainage time, the amount of analgesic used, hospitalization time, postoperative complications, international prostate symptom score (IPSS) and International Index of Erectile Function (IIEF) scores, the extracted prostate weight, the uroflowmeter, as well as postvoiding residual (PVR) and quality of life (QoL) score at the postoperative third month, were analyzed. The cost of both techniques was also compared statistically. No statistical differences were found in the preoperative parameters, including age, IPSS and QoL score, maximum flow rate (Qmax), PVR, IIEF score, and prostate volumes, as measured by transabdominal ultrasonography. No statistical differences were established in terms of the OT and the weight of the extracted prostate. No differences were established with regard to complications according to Clavien's classification in groups. However, the bleeding rate was significantly lower in group 2. The drainage, catheterization, and hospitalization times and the amount of analgesics were significantly lower in the second group. The postoperative third month findings were not different statistically. Only the Qmax values were significantly greater in group 2. While there was only a $52 difference between groups with regard to operation cost, this difference was significantly different. The use of LSP for the prostates over 80 g is more effective than the OP in terms of OT, bleeding amount, transfusion rates, catheterization time, drain removal time, hospitalization time, consumed analgesic amount, and Qmax values. On the other hand, the mean cost of the LSP is higher than OP. Better effectiveness comes with higher cost.
NASA Technical Reports Server (NTRS)
Allan, Brian; Owens, Lewis
2010-01-01
In support of the Blended-Wing-Body aircraft concept, a new flow control hybrid vane/jet design has been developed for use in a boundary-layer-ingesting (BLI) offset inlet in transonic flows. This inlet flow control is designed to minimize the engine fan-face distortion levels and the first five Fourier harmonic half amplitudes while maximizing the inlet pressure recovery. This concept represents a potentially enabling technology for quieter and more environmentally friendly transport aircraft. An optimum vane design was found by minimizing the engine fan-face distortion, DC60, and the first five Fourier harmonic half amplitudes, while maximizing the total pressure recovery. The optimal vane design was then used in a BLI inlet wind tunnel experiment at NASA Langley's 0.3-meter transonic cryogenic tunnel. The experimental results demonstrated an 80-percent decrease in DPCPavg, the reduction in the circumferential distortion levels, at an inlet mass flow rate corresponding to the middle of the operational range at the cruise condition. Even though the vanes were designed at a single inlet mass flow rate, they performed very well over the entire inlet mass flow range tested in the wind tunnel experiment with the addition of a small amount of jet flow control. While the circumferential distortion was decreased, the radial distortion on the outer rings at the aerodynamic interface plane (AIP) increased. This was a result of the large boundary layer being distributed from the bottom of the AIP in the baseline case to the outer edges of the AIP when using the vortex generator (VG) vane flow control. Experimental results, as already mentioned, showed an 80-percent reduction of DPCPavg, the circumferential distortion level at the engine fan-face. The hybrid approach leverages strengths of vane and jet flow control devices, increasing inlet performance over a broader operational range with significant reduction in mass flow requirements. Minimal distortion level requirements are met using vanes alone, avoiding engine stall and increasing robustness of this hybrid inlet flow control approach. This design applies to aerospace applications needing flush-mounted boundary-layer-ingesting inlets.
Powder Flux Regulation in the Laser Material Deposition Process
NASA Astrophysics Data System (ADS)
Arrizubieta, Jon Iñaki; Wegener, Maximiliam; Arntz, Kristian; Lamikiz, Aitzol; Ruiz, Jose Exequiel
In the present research work a powder flux regulation system has been designed, developed and validated with the aim of improving the Laser Material Deposition (LMD) process. In this process, the amount of deposited material per substrate surface unit area depends on the real feed rate of the nozzle. Therefore, a regulation system based on a solenoid valve has been installed at the nozzle entrance in order to control the powder flux. The powder flux control has been performed based on the machine real feed rate, which is compared with the programmed feed rate. An instantaneous velocity error is calculated and the powder flow is controlled as a function of this variation using Pulse Width Modulation (PWM) signals. Thereby, in zones where the Laser Material Deposition machine reduces the feed rate due to a trajectory change, powder accumulation can be avoided and the generated clads would present a homogeneous shape.
Mullaney, John R.
2004-01-01
Ground-water budgets were developed for 32 small basin-based zones in the Greenwich area of southwestern Connecticut, where crystalline-bedrock aquifers supply private wells, to determine the status of residential ground-water consumption relative to rates of ground-water recharge and discharge. Estimated residential ground-water withdrawals for small basins (averaging 1.7 square miles (mi2)) ranged from 0 to 0.16 million gallons per day per square mile (Mgal/d/mi2). To develop these budgets, residential ground-water withdrawals were estimated using multiple-linear regression models that relate water use from public water supply to data on residential property characteristics. Average daily water use of households with public water supply ranged from 219 to 1,082 gallons per day (gal/d). A steady-state finite-difference ground-water- flow model was developed to track water budgets, and to estimate optimal values for hydraulic conductivity of the bedrock (0.05 feet per day) and recharge to the overlying till deposits (6.9 inches) using nonlinear regression. Estimated recharge rates to the small basins ranged from 3.6 to 7.5 inches per year (in/yr) and relate to the percentage of the basin underlain by coarse- grained glacial stratified deposits. Recharge was not applied to impervious areas to account for the effects of urbanization. Net residential ground-water consumption was estimated as ground-water withdrawals increased during the growing season, and ranged from 0 to 0.9 in/yr. Long-term average stream base flows simulated by the ground-water-flow model were compared to calculated values of average base flow and low flow to determine if base flow was substantially reduced in any of the basins studied. Three of the 32 basins studied had simulated base flows less than 3 in/yr, as a result of either ground-water withdrawals or reduced recharge due to urbanization. A water-availability criteria of the difference between the 30-day 2-year low flow and the recharge rate for each basin was explored as a method to rate the status of water consumption in each basin. Water consumption ranged from 0 to 14.3 percent of available water based on this criteria for the 32 basins studied. Base-flow water quality was related to the amount of urbanized area in each basin sampled. Concentrations of total nitrogen and phosphorus, chloride, indicator bacteria, and the number of pesticide detections increased with basin urbanization, which ranged from 18 to 63 percent of basin area.
Bell, Geoffrey C.; Feustel, Helmut E.; Dickerhoff, Darryl J.
2002-01-01
A fume hood is provided having an adequate level of safety while reducing the amount of air exhausted from the hood. A displacement flow fume hood works on the principal of a displacement flow which displaces the volume currently present in the hood using a push-pull system. The displacement flow includes a plurality of air supplies which provide fresh air, preferably having laminar flow, to the fume hood. The displacement flow fume hood also includes an air exhaust which pulls air from the work chamber in a minimally turbulent manner. As the displacement flow produces a substantially consistent and minimally turbulent flow in the hood, inconsistent flow patterns associated with contaminant escape from the hood are minimized. The displacement flow fume hood largely reduces the need to exhaust large amounts of air from the hood. It has been shown that exhaust air flow reductions of up to 70% are possible without a decrease in the hood's containment performance. The fume hood also includes a number of structural adaptations which facilitate consistent and minimally turbulent flow within a fume hood.
Lenčo, Juraj; Vajrychová, Marie; Pimková, Kristýna; Prokšová, Magdaléna; Benková, Markéta; Klimentová, Jana; Tambor, Vojtěch; Soukup, Ondřej
2018-04-17
Due to its sensitivity and productivity, bottom-up proteomics based on liquid chromatography-mass spectrometry (LC-MS) has become the core approach in the field. The de facto standard LC-MS platform for proteomics operates at sub-μL/min flow rates, and nanospray is required for efficiently introducing peptides into a mass spectrometer. Although this is almost a "dogma", this view is being reconsidered in light of developments in highly efficient chromatographic columns, and especially with the introduction of exceptionally sensitive MS instruments. Although conventional-flow LC-MS platforms have recently penetrated targeted proteomics successfully, their possibilities in discovery-oriented proteomics have not yet been thoroughly explored. Our objective was to determine what are the extra costs and what optimization and adjustments to a conventional-flow LC-MS system must be undertaken to identify a comparable number of proteins as can be identified on a nanoLC-MS system. We demonstrate that the amount of a complex tryptic digest needed for comparable proteome coverage can be roughly 5-fold greater, providing the column dimensions are properly chosen, extra-column peak dispersion is minimized, column temperature and flow rate are set to levels appropriate for peptide separation, and the composition of mobile phases is fine-tuned. Indeed, we identified 2 835 proteins from 2 μg of HeLa cells tryptic digest separated during a 60 min gradient at 68 μL/min on a 1.0 mm × 250 mm column held at 55 °C and using an aqua-acetonitrile mobile phases containing 0.1% formic acid, 0.4% acetic acid, and 3% dimethyl sulfoxide. Our results document that conventional-flow LC-MS is an attractive alternative for bottom-up exploratory proteomics.
NASA Astrophysics Data System (ADS)
Cheng, Zhen; Chauchat, Julien; Hsu, Tian-Jian; Calantoni, Joseph
2018-01-01
A Reynolds-averaged Euler-Lagrange sediment transport model (CFDEM-EIM) was developed for steady sheet flow, where the inter-granular interactions were resolved and the flow turbulence was modeled with a low Reynolds number corrected k - ω turbulence closure modified for two-phase flows. To model the effect of turbulence on the sediment suspension, the interaction between the turbulent eddies and particles was simulated with an eddy interaction model (EIM). The EIM was first calibrated with measurements from dilute suspension experiments. We demonstrated that the eddy-interaction model was able to reproduce the well-known Rouse profile for suspended sediment concentration. The model results were found to be sensitive to the choice of the coefficient, C0, associated with the turbulence-sediment interaction time. A value C0 = 3 was suggested to match the measured concentration in the dilute suspension. The calibrated CFDEM-EIM was used to model a steady sheet flow experiment of lightweight coarse particles and yielded reasonable agreements with measured velocity, concentration and turbulence kinetic energy profiles. Further numerical experiments for sheet flow suggested that when C0 was decreased to C0 < 3, the simulation under-predicted the amount of suspended sediment in the dilute region and the Schmidt number is over-predicted (Sc > 1.0). Additional simulations for a range of Shields parameters between 0.3 and 1.2 confirmed that CFDEM-EIM was capable of predicting sediment transport rates similar to empirical formulations. Based on the analysis of sediment transport rate and transport layer thickness, the EIM and the resulting suspended load were shown to be important when the fall parameter is less than 1.25.
An efficient and rapid transgenic pollen screening and detection method using flow cytometry.
Moon, Hong S; Eda, Shigetoshi; Saxton, Arnold M; Ow, David W; Stewart, C Neal
2011-01-01
Assaying for transgenic pollen, a major vector of transgene flow, provides valuable information and essential data for the study of gene flow and assessing the effectiveness of transgene containment. Most studies have employed microscopic screening methods or progeny analyses to estimate the frequency of transgenic pollen. However, these methods are time-consuming and laborious when large numbers of pollen grains must be analyzed to look for rare transgenic pollen grains. Thus, there is an urgent need for the development of a simple, rapid, and high throughput analysis method for transgenic pollen analysis. In this study, our objective was to determine the accuracy of using flow cytometry technology for transgenic pollen quantification in practical application where transgenic pollen is not frequent. A suspension of non-transgenic tobacco pollen was spiked with a known amount of verified transgenic tobacco pollen synthesizing low or high amounts of green fluorescent protein (GFP). The flow cytometric method detected approximately 75% and 100% of pollen grains synthesizing low and high amounts of GFP, respectively. The method is rapid, as it is able to count 5000 pollen grains per minute-long run. Our data indicate that this flow cytometric method is useful to study gene flow and assessment of transgene containment.
Limits to preference and the sensitivity of choice to rate and amount of food.
Aparicio, Carlos F; Baum, William M; Hughes, Christine E; Pitts, Raymond C
2016-03-01
Studies of choice holding food-amount ratio constant while varying food-rate ratio within sessions showed that local changes in preference depend on relative amount of food. The present study investigated whether sensitivity of choice to food-rate ratio and sensitivity to food-amount ratio are independent of one another when food-rate ratios are varied across sessions and food-amount ratios are varied within sessions. Food deliveries for rats' presses on the left and right levers were scheduled according to three different food-rate ratios of 1:1, 9:1, and 1:9; each food-rate ratio lasted for 106 sessions and was arranged independently of seven food-amount ratios (7:1, 6:2, 5:3, 4:4, 3:5, 2:6, and 1:7 food pellets) occurring within sessions in random sequence. Each amount ratio lasted for 10 food deliveries and was separated from another by a 60-s blackout. Sensitivity to rate ratio was high (1.0) across food deliveries. Sensitivity to amount ratio was low when food rates were equal across alternatives, but was high when rate ratio and amount ratio opposed one another. When rate ratio and amount ratio went in the same direction, choice ratio reached an elevenfold limit which reduced sensitivity to approximately zero. We conclude that three factors affect sensitivity to amount: (1) the limit to preference, (2) the equal effect on preference of amounts greater than four pellets, and (3) the absence of differential effects of switches in amount in the equal-rates (1:1) condition. Taken together, these findings indicate that rate and amount only sometimes combine independently as additive variables to determine preference when amount ratios vary frequently within sessions. © 2016 Society for the Experimental Analysis of Behavior.
Prostate Cancer: Improving the Flow of Research.
Lawton, Colleen A F
2018-04-01
Prostate cancer is the most common nonskin cancer diagnosed in U.S. men and kills over 27 000 men annually. Thus, improving the outcomes for patients diagnosed with this disease is imperative. There has been a considerable amount of research done over the past several decades resulting in more cures than ever, but the death rate is still unacceptable. This oration addresses the progress that we have made over the past several decades and outlines the work yet to be done, as well as some processes to make that work happen. © RSNA, 2018.
NASA Technical Reports Server (NTRS)
Coe, H. H.; Huller, F. T.
1980-01-01
Bearing inner and outer race temperatures and the amount of heat transferred to the lubricant were calculated by using the computer program CYBEAN. The results obtained were compared with previously reported experimental data for a 118 mm bore roller bearing that operated at shaft speeds to 25,500 rpm, radial loads to 8,900 N (2000 lb), and total lubricant flow rates to 0.0102 cu m/min (2.7 gal/min). The calculated results compared well with the experimental data.
Effect of Divalent Electrolytes on Electroosmotic Flow
NASA Astrophysics Data System (ADS)
Li, Haifeng; Gnanaprakasam, Pradeep
2005-11-01
Electroosmotic flow (EOF) is of importance in micro- and nanofluidic applications. Recent numerical results [Zheng et al. (2003) Electrophoresis 24, 3006] suggest that the addition of even trace amounts of divalent counterions can greatly affect the velocity and electric potential distribution for EOF of a nominally monovalent electrolyte solution, nearly halving the flow rate in 20 nm channels. Scaled experiments were therefore carried out for steady and fully-developed EOF of buffered aqueous mono- and divalent electrolyte mixtures through fused silica microchannels. Nano-particle image velocimetry (nPIV), based upon evanescent-wave illumination of colloidal tracers, was used to obtain velocity data within about 300 nm of the wall. In all cases, the thickness of the electric double layer, defined as the distance from the wall where the velocity and electric potential recover to 99% of their freestream values, is of O(10 nm), or much less than the channel dimension of O(10 μm). The nPIV results are compared with predictions from an asymptotic perturbation analysis.
NASA Technical Reports Server (NTRS)
Schumann, H. H. (Principal Investigator)
1972-01-01
The author has identified the following significant results. Preliminary analysis of DCS data from the USGS Verde River stream flow measuring site indicates the DCS system is furnishing high quality data more frequently than had been expected. During the 43-day period between Nov. 3, and Dec. 15, 1972, 552 DCS transmissions were received during 193 data passes. The amount of data received far exceeded the single high quality transmission per 12-hour period expected from the DCS system. The digital-parallel ERTS-1 data has furnished sufficient to accurately compute mean daily gage heights. These in turn, are used to compute average daily streamflow rates during periods of stable or slowly changing flow conditions. The digital-parallel data has also furnished useful information during peak flow periods. However, the serial-digital DCS capability, currently under development for transmitting streamflow data, should provide data of greater utility for determining times of flood peaks.
Lo, Chi-Wen; Liu, Jia-Shing; Li, Chi-Pei; Lu, Po-Chien; Hwang, Ned H
2008-01-01
Accelerated testing provides a substantial amount of data on mechanical heart valve durability in a short period of time, but such conditions may not accurately reflect in vivo performance. Cavitation, which occurs during mechanical heart valve closure when local flow field pressure decreases below vapor pressure, is thought to play a role in valve damage under accelerated conditions. The underlying flow dynamics and mechanisms behind cavitation bubble formation are poorly understood. Under physiologic conditions, random perivalvular cavitation is difficult to capture. We applied accelerated testing at a pulse rate of 600 bpm and transvalvular pressure of 120 mm Hg, with synchronized videographs and high-frequency pressure measurements, to study cavitation of the Medtronic Hall Standard (MHS), Medtronic Hall D-16 (MHD), and Omni Carbon (OC) valves. Results showed cavitation bubbles between 340 and 360 micros after leaflet/housing impact of the MHS, MHD, and OC valves, intensified by significant leaflet rebound. Squeeze flow, Venturi, and water hammer effects each contributed to cavitation, depending on valve design.
Internet traffic load balancing using dynamic hashing with flow volume
NASA Astrophysics Data System (ADS)
Jo, Ju-Yeon; Kim, Yoohwan; Chao, H. Jonathan; Merat, Francis L.
2002-07-01
Sending IP packets over multiple parallel links is in extensive use in today's Internet and its use is growing due to its scalability, reliability and cost-effectiveness. To maximize the efficiency of parallel links, load balancing is necessary among the links, but it may cause the problem of packet reordering. Since packet reordering impairs TCP performance, it is important to reduce the amount of reordering. Hashing offers a simple solution to keep the packet order by sending a flow over a unique link, but static hashing does not guarantee an even distribution of the traffic amount among the links, which could lead to packet loss under heavy load. Dynamic hashing offers some degree of load balancing but suffers from load fluctuations and excessive packet reordering. To overcome these shortcomings, we have enhanced the dynamic hashing algorithm to utilize the flow volume information in order to reassign only the appropriate flows. This new method, called dynamic hashing with flow volume (DHFV), eliminates unnecessary flow reassignments of small flows and achieves load balancing very quickly without load fluctuation by accurately predicting the amount of transferred load between the links. In this paper we provide the general framework of DHFV and address the challenges in implementing DHFV. We then introduce two algorithms of DHFV with different flow selection strategies and show their performances through simulation.
Characteristics of a-IGZO/ITO hybrid layer deposited by magnetron sputtering.
Bang, Joon-Ho; Park, Hee-Woo; Cho, Sang-Hyun; Song, Pung-Keun
2012-04-01
Transparent a-IGZO (In-Ga-Zn-O) films have been actively studied for use in the fabrication of high-quality TFTs. In this study, a-IGZO films and a-IGZO/ITO double layers were deposited by DC magnetron sputtering under various oxygen flow rates. The a-IGZO films showed an amorphous structure up to 500 degrees C. The deposition rate of these films decreased with an increase in the amount of oxygen gas. The amount of indium atoms in the film was confirmed to be 11.4% higher than the target. The resistivity of double layer follows the rules for parallel DC circuits The maximum Hall mobility of the a-IGZO/ITO double layers was found to be 37.42 cm2/V x N s. The electrical properties of the double layers were strongly dependent on their thickness ratio. The IGZO/ITO double layer was subjected to compressive stress, while the ITO/IGZO double layer was subjected to tensile stress. The bending tolerance was found to depend on the a-IGZO thickness.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Laurinat, J.; Kesterson, M.; Hensel, S.
The documented safety analysis for the Savannah River Site evaluates the consequences of a postulated 1000 °C fire in a glovebox. The radiological dose consequences for a pressurized release of plutonium oxide powder during such a fire depend on the maximum pressure that is attained inside the oxide storage vial. To enable evaluation of the dose consequences, pressure transients and venting flow rates have been calculated for exposure of the storage vial to the fire. A standard B vial with a capacity of approximately 8 cc was selected for analysis. The analysis compares the pressurization rate from heating and evaporationmore » of moisture adsorbed onto the plutonium oxide contents of the vial with the pressure loss due to venting of gas through the threaded connection between the vial cap and body. Tabulated results from the analysis include maximum pressures, maximum venting velocities, and cumulative vial volumes vented during the first 10 minutes of the fire transient. Results are obtained for various amounts of oxide in the vial, various amounts of adsorbed moisture, different vial orientations, and different surface fire exposures.« less
A model for oxygen conservation associated with titration during pediatric oxygen therapy
Wu, Grace; Wollen, Alec; Himley, Stephen; Austin, Glenn; Delarosa, Jaclyn; Izadnegahdar, Rasa; Ginsburg, Amy Sarah; Zehrung, Darin
2017-01-01
Background Continuous oxygen treatment is essential for managing children with hypoxemia, but access to oxygen in low-resource countries remains problematic. Given the high burden of pneumonia in these countries and the fact that flow can be gradually reduced as therapy progresses, oxygen conservation through routine titration warrants exploration. Aim To determine the amount of oxygen saved via titration during oxygen therapy for children with hypoxemic pneumonia. Methods Based on published clinical data, we developed a model of oxygen flow rates needed to manage hypoxemia, assuming recommended flow rate at start of therapy, and comparing total oxygen used with routine titration every 3 minutes or once every 24 hours versus no titration. Results Titration every 3 minutes or every 24 hours provided oxygen savings estimated at 11.7% ± 5.1% and 8.1% ± 5.1% (average ± standard error of the mean, n = 3), respectively. For every 100 patients, 44 or 30 kiloliters would be saved—equivalent to 733 or 500 hours at 1 liter per minute. Conclusions Ongoing titration can conserve oxygen, even performed once-daily. While clinical validation is necessary, these findings could provide incentive for the routine use of pulse oximeters for patient management, as well as further development of automated systems. PMID:28234903
Ohta, Tomoaki; Maeda, Hiroyuki; Kubota, Ryuji; Koga, Akiko; Terada, Katsuhide
2014-09-10
The ratio of high potent materials in the new chemical entities has recently increased in the pharmaceutical industry. Generally, most of them are highly hazardous, but there is little toxicity information about the active pharmaceutical ingredients in the early development period. Even if their handling amount is quite small, the dustiness of high potent powder generated in the manufacturing process has an important impact on worker health; thus, it is important to understand the powder dustiness. The purpose of this study was to establish a method to evaluate the powder dustiness by the consumption of small amount of samples. The optimized measurement conditions for a commercially available dustmeter were confirmed using lactose monohydrate and naproxen sodium. The optimized test conditions were determined: the dustmeter mode, the flow rate, the drum rotation speed, the total measurement time, and sample loaded weight were type I mode, 4 L/min, 10 rpm, 1 min and 1-10 g , respectively. The setup conditions of the dustmeter are considerably valuable to pharmaceutical industries, especially, at the early development stage and especially for expensive materials, because the amount of air-borne dust can be evaluated with accuracy by the consumption of small amount of samples. Copyright © 2014 Elsevier B.V. All rights reserved.
Spencer, Shannon B; Wang, Shigang; Woitas, Karl; Glass, Kristen; Kunselman, Allen R; Ündar, Akif
2017-01-01
The objective of this study was to evaluate an alternative neonatal extracorporeal life support (ECLS) circuit with a RotaFlow centrifugal pump and Better-Bladder (BB) for hemodynamic performance and gaseous microemboli (GME) capture in a simulated neonatal ECLS system. The circuit consisted of a Maquet RotaFlow centrifugal pump, a Quadrox-iD Pediatric diffusion membrane oxygenator, 8 Fr arterial cannula, and 10 Fr venous cannula. A "Y" connector was inserted into the venous line to allow for comparison between BB and no BB. The circuit and pseudopatient were primed with lactated Ringer's solution and packed human red blood cells (hematocrit 35%). All hemodynamic trials were conducted at flow rates ranging from 100 to 600 mL/min at 36°C. Real-time pressure and flow data were recorded using a data acquisition system. For GME testing, 0.5 cc of air was injected via syringe into the venous line. GME were detected and characterized with or without the BB using the Emboli Detection and Classification Quantifier (EDAC) System. Trials were conducted at flow rates ranging from 200 to 500 mL/min. The hemodynamic energy data showed that up to 75.2% of the total hemodynamic energy was lost from the circuit. The greatest pressure drops occurred across the arterial cannula and increased with increasing flow rate from 10.1 mm Hg at 100 mL/min to 114.3 mm Hg at 600 mL/min. The EDAC results showed that the BB trapped a significant amount of the GME in the circuit. When the bladder was removed, GME passed through the pump head and the oxygenator to the arterial line. This study showed that a RotaFlow centrifugal pump combined with a BB can help to significantly decrease the number of GME in a neonatal ECLS circuit. Even with this optimized alternative circuit, a large percentage of the total hemodynamic energy was lost. The arterial cannula was the main source of resistance in the circuit. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Betts, Duncan Colin; Müller, Ralph; Hofmann, Sandra
2017-01-01
Mechanical loading plays a major role in bone remodeling and fracture healing. Mimicking the concept of mechanical loading of bone has been widely studied in bone tissue engineering by perfusion cultures. Nevertheless, there is still debate regarding the in-vitro mechanical stimulation regime. This study aims at investigating the effect of two different flow rates (vlow = 0.001m/s and vhigh = 0.061m/s) on the growth of mineralized tissue produced by human mesenchymal stromal cells cultured on 3-D silk fibroin scaffolds. The flow rates applied were chosen to mimic the mechanical environment during early fracture healing or during bone remodeling, respectively. Scaffolds cultured under static conditions served as a control. Time-lapsed micro-computed tomography showed that mineralized extracellular matrix formation was completely inhibited at vlow compared to vhigh and the static group. Biochemical assays and histology confirmed these results and showed enhanced osteogenic differentiation at vhigh whereas the amount of DNA was increased at vlow. The biological response at vlow might correspond to the early stage of fracture healing, where cell proliferation and matrix production is prominent. Visual mapping of shear stresses, simulated by computational fluid dynamics, to 3-D micro-computed tomography data revealed that shear stresses up to 0.39mPa induced a higher DNA amount and shear stresses between 0.55mPa and 24mPa induced osteogenic differentiation. This study demonstrates the feasibility to drive cell behavior of human mesenchymal stromal cells by the flow velocity applied in agreement with mechanical loading mimicking early fracture healing (vlow) or bone remodeling (vhigh). These results can be used in the future to tightly control the behavior of human mesenchymal stromal cells towards proliferation or differentiation. Additionally, the combination of experiment and simulation presented is a strong tool to link biological responses to mechanical stimulation and can be applied to various in-vitro cultures to improve the understanding of the cause-effect relationship of mechanical loading. PMID:28686698
Álvarez-Martín, Alba; Sánchez-Martín, María J; Ordax, José M; Marín-Benito, Jesús M; Sonia Rodríguez-Cruz, M
2017-04-15
A study has been conducted on the leaching of two fungicides, tebuconazole and cymoxanil, in a soil amended with spent mushroom substrate (SMS), with an evaluation of how different factors influence this process. The objective was based on the potential use of SMS as a biosorbent for immobilizing pesticides in vulnerable soils, and the need to know how it could affect the subsequent transport of these retained compounds. Breakthrough curves (BTCs) for 14 C-fungicides, non-incubated and incubated over 30days, were obtained in columns packed with an unamended soil (S), and this soil amended with SMS at rates of 5% (S+SMS5) and 50% (S+SMS50) under saturated and saturated-unsaturated flows. The highest leaching of tebuconazole (>50% of the total 14 C added) was found in S when a saturated water flow was applied to the column, but the percentage of leached fungicide decreased when a saturated-unsaturated flow was applied in both SMS-amended soils. Also a significant decrease in leaching was observed for tebuconazole after incubation in the column, especially in S+SMS50 when both flows were applied. Furthermore, cymoxanil leaching was complete in S and S+SMS when a saturated flow was applied, and maximum peak concentrations were reached at 1pore volume (PV), although BTCs showed peaks with lower concentrations in S+SMS. The amounts of cymoxanil retained only increased in S+SMS when a saturated-unsaturated flow was applied. A more relevant effect of SMS for reducing the leaching of fungicide was observed when cymoxanil was previously incubated in the column, although mineralization was enhanced in this case. These results are of interest for extending SMS application on the control of the leaching of fungicides with different physicochemical characteristics after different ageing times in the soil and water flow conditions applied. Copyright © 2017 Elsevier B.V. All rights reserved.
Ford, Stephanie M; McPheeters, Matthew T; Wang, Yves T; Ma, Pei; Gu, Shi; Strainic, James; Snyder, Christopher; Rollins, Andrew M; Watanabe, Michiko; Jenkins, Michael W
2017-01-01
Background The relationship between changes in endocardial cushion and resultant congenital heart diseases (CHD) has yet to be established. It has been shown that increased regurgitant flow early in embryonic heart development leads to endocardial cushion defects, but it remains unclear how abnormal endocardial cushions during the looping stages might affect the fully septated heart. The goal of this study was to reproducibly alter blood flow in vivo and then quantify the resultant effects on morphology of endocardial cushions in the looping heart and on CHDs in the septated heart. Methods Optical pacing was applied to create regurgitant flow in embryonic hearts, and optical coherence tomography (OCT) was utilized to quantify regurgitation and morphology. Embryonic quail hearts were optically paced at 3 Hz (180bpm, well above intrinsic rate 60–110bpm) at stage 13 of development (3–4 wks human) for 5 min. Pacing fatigued the heart and led to at least 1 hr of increased regurgitant flow. Resultant morphological changes were quantified with OCT imaging at stage 19 (cardiac looping – 4–5 wks human) or stage 35 (4 chambered heart – 8 wks human). Results All paced embryos imaged at stage 19 displayed structural changes in cardiac cushions. The amount of regurgitant flow immediately after pacing was inversely correlated with cardiac cushion size 24-hrs post pacing (p-value < 0.01). The embryos with the most regurgitant flow and smallest cushions after pacing had a decreased survival rate at 8 days (p<0.05), indicating that those most severe endocardial cushion defects were lethal. Of the embryos that survived to stage 35, 17/18 exhibited CHDs including valve defects, ventricular septal defects, hypoplastic ventricles, and common AV canal. Conclusion The data illustrate a strong inverse relationship in which regurgitant flow precedes abnormal and smaller cardiac cushions, resulting in the development of CHDs. PMID:28211263
Harden, Stephen L.; Spruill, Timothy B.
2008-01-01
An analysis of data collected at five flow-path study sites between 1997 and 2006 was performed to identify the factors needed to formulate a comprehensive program, with a focus on nitrogen, for protecting ground water and surface water in the North Carolina Coastal Plain. Water-quality protection in the Coastal Plain requires the identification of factors that affect the transport of nutrients from recharge areas to streams through the shallow ground-water system. Some basins process or retain nitrogen more readily than others, and the factors that affect nitrogen processing and retention were the focus of this investigation to improve nutrient management in Coastal Plain streams and to reduce nutrient loads to coastal waters. Nitrate reduction in ground water was observed at all five flow-path study sites in the North Carolina Coastal Plain, although the extent of reduction at each site was influenced by various environmental, hydrogeologic, and geochemical factors. Denitrification was the most common factor responsible for decreases in nitrate along the ground-water flow paths. Specific factors, some of which affect denitrification rates, that appeared to influence ground-water nitrate concentrations along the flow paths or in the streams include soil drainage, presence or absence of riparian buffers, evapotranspiration, fertilizer use, ground-water recharge rates and residence times, aquifer properties, subsurface tile drainage, sources and amounts of organic matter, and hyporheic processes. The study data indicate that the nitrate-reducing capacity of the buffer zone combined with that of the hyporheic zone can substantially lower the amount of ground-water nitrate discharged to streams in agricultural settings of the North Carolina Coastal Plain. At the watershed scale, the effects of ground-water discharge on surface-water quality appear to be greatly influenced by streamflow conditions and the presence of extensive riparian vegetation. Streamflow statistics that reflect base flow and the general hydrologic dynamics of a stream are important in understanding nutrient transport from a watershed and may be useful indicators of watersheds that are likely to have higher yields of nutrients and water. Combining streamflow statistics with information on such factors as land use, soil drainage, extent of riparian vegetation, geochemical conditions, and subsurface tile drainage in the Coastal Plain can be useful in identifying watersheds that are most likely to export excessive nitrogen due to nonpoint-source loadings and watersheds that are effective in processing nitrogen.
Theoretical Investigation For The Effect of Fuel Quality on Gas Turbine Power Plants
NASA Astrophysics Data System (ADS)
AbdulRazzak khudair, Omar; Alwan Abass, Khetam; Saadi Abed, Noor; Hussain Ali, Khalid; AbdulAziz, Saad; Chlaib Shaboot, Ali
2018-05-01
Gas turbine engine power generation is declined dramatically because of the reduction in thermodynamic parameters as a work of turbine, compressor ratio, compressor work, and air mass flow rate and fuel consumption. There are two main objectives of this work, the first is related with the effect of fuel kinds and their quality on the operation of fuel flow divider and its performance specifically gear pump displacement and fuel flow rate to the combustion chambers of gas power plant. AL-DORA gas turbine power plant 35MW was chosen to predict these effects on its performance MATLAB Software program is used to perform thermodynamic calculations. Fuel distribution stage before the process of combustion and as a result of the kind and its quality, chemical reaction will occur between the fuel and the parts of the gear system of each pump of the flow divider, which causes the erosion of the internal pump wall and the teeth of the gear system, thus hampering the pump operation in terms of fuel discharge. The discharge of fuel form the eight external gates of flow divider is decreased and varied when going to the combustion chambers, so that, flow divider does not give reliable mass flow rate due to absence of accurate pressure in each of eight exit pipes. The second objective deals with the stage of fuel combustion process inside the combustion chamber. A comparative study based upon performance parameters, such as specific fuel consumption for gas and gasoil and power generation. Fuel poor quality causes incomplete combustion and increased its consumption, so that combustion products are interacted with the surface of the turbine blades, causing the erosion and create surface roughness of the blade and disruption of gas flow. As a result of this situation, turbulence flow of these gases will increase causing the separation of gas boundary layers over the suction surface of the blade. Therefore the amount of extracted gas will decrease causing retreat work done by turbine, as a result decline of power and gas turbine power plant efficiency causing the drop in the level of electric generation. The fuel quality is found to be a strong function of specific fuel consumption and its effects on the power generation and the efficiency of the gas turbine power plants and hence, the cycle performance shifts towards favorable conditions.
Jorgensen, Donald G.; Signor, Donald C.; Imes, Jeffrey L.
1989-01-01
Intracell flow is important in modeling cells that contain both sources and sinks. Special attention is needed if recharge through the water table is a source. One method of modeling multiple sources and sinks is to determine the net recharge per cell. For example, for a model cell containing both a sink and recharge through the water table, the amount of recharge should be reduced by the ratio of the area of influence of the sink within the cell to the area of the cell. The reduction is the intercepted portion of the recharge. In a multilayer model this amount is further reduced by a proportion factor, which is a function of the depth of the flow lines from the water table boundary to the internal sink. A gaining section of a stream is a typical sink. The aquifer contribution to a gaining stream can be conceptualized as having two parts; the first part is the intercepted lateral flow from the water table and the second is the flow across the streambed due to differences in head between the water level in the stream and the aquifer below. The amount intercepted is a function of the geometry of the cell, but the amount due to difference in head across the stream bed is largely independent of cell geometry. A discharging well can intercept recharge through the water table within a model cell. The net recharge to the cell would be reduced in proportion to the area of influence of the well within the cell. The area of influence generally changes with time. Thus the amount of intercepted recharge and net recharge may not be constant with time. During periods when the well is not discharging there will be no intercepted recharge even though the area of influence from previous pumping may still exist. The reduction of net recharge per cell due to internal interception of flow will result in a model-calculated mass balance less than the prototype. Additionally the “effective transmissivity” along the intercell flow paths may be altered when flow paths are occupied by intercepted recharge.
Polski, Andrzej; Iwaniak, Karol; Kasperek, Regina; Modrzewska, Joanna; Sobótka-Polska, Karolina; Sławińska, Karolina; Poleszak, Ewa
2015-01-01
The capsule is one of the most important solid dosage forms in the pharmaceutical industry. It is easier and faster to produce than a tablet, because it requires fewer excipients. Generally, capsules are easy to swallow and mask any unpleasant taste of the substances used while their release profiles can be easily modified. Papaverine hydrochloride was used as a model substance to show different release profiles using different excipients. The main aim of the study was to analyze the impact of using different polymers on the release profile of papaverine hydrochloride from hard gelatin capsules. Six series of hard gelatin capsules containing papaverine hydrochloride as a model drug and different excipients were made. Then, the angle of repose, flow rate, mass flow rate and volume flow rate of the powders used for capsule production were analyzed. The uniform weight and disintegration time of the capsules were studied. The dissolution study was performed in a basket apparatus, while the amount of papaverine hydrochloride released was determined spectrophotometrically at 251 nm. Only one formula of powder had satisfactory flow properties, while all formulas had good Hausner ratios. The best properties were from powder containing polyvinylpyrrolidone 10k. The disintegration time of capsules varied from 1:30 min to 2:00 min. As required by Polish Pharmacopoeia X, 80% of the active substance in all cases was released within 15 minutes. The capsules with polyvinylpyrrolidone 10k were characterized by the longest release. On the other hand, capsules containing microcrystalline cellulose had the fastest release profile. Using 10% of different polymers, without changing the other excipients, had a significant impact on the physical properties of the powders and papaverine hydrochloride release profile. The two most preferred capsule formulations contained either polyvinylpyrrolidone 10k or microcrystalline cellulose.
NASA Astrophysics Data System (ADS)
Endale, Dinku M.; Fisher, Dwight S.; Steiner, Jean L.
2006-01-01
Few studies have reported runoff from small agricultural watersheds over sufficiently long period so that the effect of different cover types on runoff can be examined. We analyzed 45-yrs of monthly and annual rainfall-runoff characteristics of a small (7.8 ha) zero-order typical Southern Piedmont watershed in southeastern United States. Agricultural land use varied as follows: 1. Row cropping (5-yrs); 2. Kudzu ( Pueraria lobata; 5-yrs); 3. Grazed kudzu and rescuegrass ( Bromus catharticus; 7-yrs); and 4. Grazed bermudagrass and winter annuals ( Cynodon dactylon; 28-yrs). Land use and rainfall variability influenced runoff characteristics. Row cropping produced the largest runoff amount, percentage of the rainfall partitioned into runoff, and peak flow rates. Kudzu reduced spring runoff and almost eliminated summer runoff, as did a mixture of kudzu and rescuegrass (KR) compared to row cropping. Peak flow rates were also reduced during the kudzu and KR. Peak flow rates increased under bermudagrass but were lower than during row cropping. A simple process-based 'tanh' model modified to take the previous month's rainfall into account produced monthly rainfall and runoff correlations with coefficient of determination ( R2) of 0.74. The model was tested on independent data collected during drought. Mean monthly runoff was 1.65 times the observed runoff. Sustained hydrologic monitoring is essential to understanding long-term rainfall-runoff relationships in agricultural watersheds.
Revisiting resolution in hydrodynamic countercurrent chromatography: tubing bore effect.
Berthod, A; Faure, K
2015-04-17
A major challenge in countercurrent chromatography (CCC), the technique that works with a support-free biphasic liquid system, is to retain the liquid stationary phase inside the CCC column (Sf parameter). Two solutions are commercially available: the hydrostatic CCC columns, also called centrifugal partition chromatographs (CPC), with disks of interconnected channels and rotary seals, and the hydrodynamic CCC columns with bobbins of coiled open tube and no rotary seals. It was demonstrated that the amount of liquid stationary phase retained by a coiled tube was higher with larger bore tubing than with small bore tubes. At constant column volume, small bore tubing will be longer producing more efficiency than larger bore tube that will better retain the liquid stationary phase. Since the resolution equation in CCC is depending on both column efficiency and stationary phase retention ratio, the influence of the tubing bore should be studied. This theoretical work showed that there is an optimum tubing bore size depending on solute partition coefficient and mobile phase flow rate. The interesting result of the theoretical study is that larger tubing bores allow for dramatically reduced experiment durations for all solutes: in reversed phase CCC (polar mobile phase), hydrophobic solutes are usually highly retained. These apolar solutes can be separated by the same coil at high flow rates and reduced Sf with similar retention times as polar solutes separated at smaller flow rates and much higher Sf. Copyright © 2015 Elsevier B.V. All rights reserved.
Zhao, Kai; Dalton, Pamela; Yang, Geoffery C; Scherer, Peter W
2006-02-01
Human sniffing behavior usually involves bouts of short, high flow rate inhalation (>300 ml/s through each nostril) with mostly turbulent airflow. This has often been characterized as a factor enabling higher amounts of odorant to deposit onto olfactory mucosa than for laminar airflow and thereby aid in olfactory detection. Using computational fluid dynamics human nasal cavity models, however, we found essentially no difference in predicted olfactory odorant flux (g/cm2 s) for turbulent versus laminar flow for total nasal flow rates between 300 and 1000 ml/s and for odorants of quite different mucosal solubility. This lack of difference was shown to be due to the much higher resistance to lateral odorant mass transport in the mucosal nasal airway wall than in the air phase. The simulation also revealed that the increase in airflow rate during sniffing can increase odorant uptake flux to the nasal/olfactory mucosa but lower the cumulative total uptake in the olfactory region when the inspired air/odorant volume was held fixed, which is consistent with the observation that sniff duration may be more important than sniff strength for optimizing olfactory detection. In contrast, in rats, sniffing involves high-frequency bouts of both inhalation and exhalation with laminar airflow. In rat nose odorant uptake simulations, it was observed that odorant deposition was highly dependent on solubility and correlated with the locations of different types of receptors.
Electrochemically-induced reduction of nitrate in aqueous solution
Rajic, Lj.; Berroa, D.; Gregor, S.; Elbakri, S.; MacNeil, M.; Alshawabkeh, A.N.
2018-01-01
In this study, we evaluated the removal of nitrate from synthetic groundwater by a cathode followed by an anode electrode sequence in the electrochemical flow-through reactor. We also tested the feasibility of the used electrode sequence to minimize the production of ammonia during the nitrate reduction. The performance of monometallic Fe, Cu, Ni and carbon foam cathodes was tested under different current intensities, flow rates/regimes and the presence of Pd and Ag catalyst coating. With the use of monometallic Fe and an increase in current intensity from 60 mA to 120 mA, the nitrate removal rate increased from 7.6% to 25.0%, but values above 120 mA caused a decrease in removal due to excessive gas formation at the electrodes. Among tested materials, monometallic Fe foam cathode showed the highest nitrates removal rate and increased significantly in the presence of Pd catalyst: from 25.0% to 39.8%. Further, the circulation under 3 mL min−1 elevated the nitrate removal by 33% and the final nitrate concentration fell below the maximum contaminant level of 10 mg L−1 nitrate–nitrogen (NO3-N). During the treatment, the yield of ammonia production after the cathode was 92±4% while after the anode (Ti/IrO2/Ta2O5), the amount of ammonia significantly declined to 50%. The results proved that flow-through, undivided electrochemical systems can be used to remove nitrate from groundwater with the possibility of simultaneously controlling the generation of ammonia. PMID:29657554
Shao, Qingsong; Huang, Yuqiu; Zhou, Aicun; Guo, Haipeng; Zhang, Ailian; Wang, Yong
2014-05-01
Crocus sativus has been used as a traditional Chinese medicine for a long time. The volatile compounds of C. sativus appear biologically active and may act as antioxidants as well as anticonvulsants, antidepressants and antitumour agents. In order to obtain the highest possible yield of essential oils from C. sativus, response surface methodology was employed to optimise the conditions of supercritical fluid carbon dioxide extraction of the volatile compounds from C. sativus. Four factorswere investigated: temperature, pressure, extraction time and carbon dioxide flow rate. Furthermore, the chemical compositions of the volatile compounds extracted by supercritical fluid extraction were compared with those obtained by hydro-distillation and Soxhlet extraction. The optimum extraction conditions were found to be: optimised temperature 44.9°C, pressure 34.9 MPa, extraction time 150.2 min and CO₂ flow rate 10.1 L h⁻¹. Under these conditions, the mean extraction yield was 10.94 g kg⁻¹. The volatile compounds extracted by supercritical fluid extraction and Soxhlet extraction contained a large amount of unsaturated fatty acids. Response surface methodology was successfully applied for supercritical fluid CO₂ extraction optimisation of the volatile compounds from C. sativus. The study showed that pressure and CO₂ flow rate had significant effect on volatile compounds yield produced by supercritical fluid extraction. This study is beneficial for the further research operating on a large scale. © 2013 Society of Chemical Industry.
Decomposition of dimethylamine gas with dielectric barrier discharge.
Ye, Zhaolian; Zhao, Jie; Huang, Hong ying; Ma, Fei; Zhang, Renxi
2013-09-15
The decomposition of dimethylamine (DMA) with gas under high flow rate was investigated with dielectric barrier discharge (DBD) technology. Different parameters including removal efficiency, energy yield, carbon balance and CO2 selectivity, secondary products, as well as pathways and mechanisms of DMA degradation were studied. The experimental results showed that removal efficiency of DMA depended on applied voltage and gas flow rate, but had no obvious correlation with initial concentration. Excellent energy performance was obtained using present DBD technology for DMA abatement. When experiment conditions were controlled at: gas flow rate of 14.9 m(3)/h, initial concentration of 2104 mg/m(3), applied voltage of 4.8 kV, removal efficiency of DMA and energy yield can reach 85.2% and 953.9 g/kWh, respectively. However, carbon balance (around 40%) was not ideal due to shorter residence time (about 0.1s), implying that some additional conditions should be considered to improve the total oxidation of DMA. Moreover, secondary products in outlet gas stream were detected via gas chromatogram-mass spectrum and the amounts of NO3(-) and NO2(-) were analyzed by ion chromatogram. The obtained data demonstrated that NOx might be suppressed due to reductive NH radical form DMA dissociation. The likely reaction pathways and mechanisms for the removal of DMA were suggested based on products analysis. Experimental results demonstrated the application potential of DBD as a clean technology for organic nitrogen-containing gas elimination from gas streams. Copyright © 2013 Elsevier B.V. All rights reserved.
Real-time electronic monitoring of a pitted and leaking gas gathering pipeline
DOE Office of Scientific and Technical Information (OSTI.GOV)
Asperger, R.G.; Hewitt, P.G.
1986-08-01
Hydrogen patch, flush electrical resistance, and flush linear polarization proves wre used with flush coupons to monitor corrosion rates in a pitted and leaking sour gas gathering line. Four inhibitors were evaluated in stopping the leaks. Inhibitor residuals and the amount and ratio of water and condensate in the lines were measured at five locations along the line. The best inhibitor reduced reduced the pit-leak frequency by over a factor of 10. Inhibitor usage rate was optimized using the hydrogen patch current as a measure of the instantaneous corrosion rate. Improper pigging was identified as a cause of corrosion transients.more » This problem is discussed in relation to the pigging of pipelines in stratified flow where moving fluids are the carriers for continuously injected corrosion inhibitors.« less
Monodisperse granular flows in viscous dispersions in a centrifugal acceleration field
NASA Astrophysics Data System (ADS)
Cabrera, Miguel Angel; Wu, Wei
2016-04-01
Granular flows are encountered in geophysical flows and innumerable industrial applications with particulate materials. When mixed with a fluid, a complex network of interactions between the particle- and fluid-phase develops, resulting in a compound material with a yet unclear physical behaviour. In the study of granular suspensions mixed with a viscous dispersion, the scaling of the stress-strain characteristics of the fluid phase needs to account for the level of inertia developed in experiments. However, the required model dimensions and amount of material becomes a main limitation for their study. In recent years, centrifuge modelling has been presented as an alternative for the study of particle-fluid flows in a reduced scaled model in an augmented acceleration field. By formulating simple scaling principles proportional to the equivalent acceleration Ng in the model, the resultant flows share many similarities with field events. In this work we study the scaling principles of the fluid phase and its effects on the flow of granular suspensions. We focus on the dense flow of a monodisperse granular suspension mixed with a viscous fluid phase, flowing down an inclined plane and being driven by a centrifugal acceleration field. The scaled model allows the continuous monitoring of the flow heights, velocity fields, basal pressure and mass flow rates at different Ng levels. The experiments successfully identify the effects of scaling the plastic viscosity of the fluid phase, its relation with the deposition of particles over the inclined plane, and allows formulating a discussion on the suitability of simulating particle-fluid flows in a centrifugal acceleration field.
Babu, S Hari; Suvardhan, K; Kumar, K Suresh; Reddy, K M; Rekha, D; Chiranjeevi, P
2005-04-11
A simple, sensitive and rapid flow-injection spectrophotometric method was developed for the determination of trace amounts of Au(III) in aqueous dimethylformamide (DMF). The method is based on formation of Au(III)-(3,5-DMHAAINH)3 complex. The optimum conditions for the chromogenic reaction of Au(III) with 3,5-DMHAAINH is studied and the colored (reddish brown) complex is selectively monitored at lambda(max) 490 nm at pH 6.0. The reaction and flow conditions of the full experimental design were optimized. The detection limit (2 s) of 0.1 microg l-1 Au(III) was obtained at a sampling rate of 15 samples h-1. Beer's law is obeyed over the range of 0.30-4.00 microg ml-1. The molar absorptivity and Sandell's sensitivity were 3.450x10(4) M and 0.0050 microg ml-1, respectively. Job's method of continuous variation and stability constants corresponding to these maxima was determined and found to be 9.3x10(15) (1:3, M:R) (M, metal; R, reagent). The detailed study of various interferences confirmed the high selectivity of the developed method. The method was successfully applied for the determination of trace amount of Au(III) in water and pharmaceutical samples. The results obtained were in agreement with the reported methods at the 95% confidence level.
Characterization of large-pore polymeric supports for use in perfusion biochromatography.
Whitney, D; McCoy, M; Gordon, N; Afeyan, N
1998-05-22
Perfusion chromatography is uniquely characterized by the flow of a portion of the column eluent directly through the resin in the packed bed. The benefits of this phenomenon and some of the properties of perfusive resins have been described before, and can be summarized as enhanced mass transport to interior binding sites. Here we extend the understanding of this phenomenon by comparing resins with different pore size distributions. Resins are chosen to give approximately the same specific pore volumes (as shown in the characterization section) but the varying contribution of large pores is used to control the amount of liquid flowing through the beads. POROS R1 has the largest contribution of throughpores, and therefore the greatest intraparticle flow. POROS R2 has a lower contribution of throughpores, and a higher surface area coming from a greater population of diffusive pores, but still shows significant mass transport enhancements relative to a purely diffusive control. Oligo R3 is dominated by a high population of diffusive pores, and is used comparatively as a non-perfusive resin. Although the pore size distribution can be engineered to control mass transport rates, the resulting surface area is not the only means by which binding capacity can be controlled. Surface coatings are employed to increase binding capacity without fundamentally altering the mass transport properties. Models are used to describe the amount of flow transecting the beads, and comparisons of coated resins to uncoated (polystyrene) resins leads to the conclusion that these coatings do not obstruct the throughpore structures. This is an important conclusion since the binding capacity of the coated product, in some cases, is shown to be over 10-fold higher than the precursor polystyrene scaffold (i.e., POROS R1 or POROS R2).
Delay time correction of the gas analyzer in the calculation of anatomical dead space of the lung.
Okubo, T; Shibata, H; Takishima, T
1983-07-01
By means of a mathematical model, we have studied a way to correct the delay time of the gas analyzer in order to calculate the anatomical dead space using Fowler's graphical method. The mathematical model was constructed of ten tubes of equal diameter but unequal length, so that the amount of dead space varied from tube to tube; the tubes were emptied sequentially. The gas analyzer responds with a time lag from the input of the gas signal to the beginning of the response, followed by an exponential response output. The single breath expired volume-concentration relationship was examined with three types of expired flow patterns of which were constant, exponential and sinusoidal. The results indicate that the time correction by the lag time plus time constant of the exponential response of the gas analyzer gives an accurate estimation of anatomical dead space. Time correction less inclusive than this, e.g. lag time only or lag time plus 50% response time, gives an overestimation, and a correction larger than this results in underestimation. The magnitude of error is dependent on the flow pattern and flow rate. The time correction in this study is only for the calculation of dead space, as the corrected volume-concentration curves does not coincide with the true curve. Such correction of the output of the gas analyzer is extremely important when one needs to compare the dead spaces of different gas species at a rather faster flow rate.
Thin liquid films with time-dependent chemical reactions sheared by an ambient gas flow
NASA Astrophysics Data System (ADS)
Bender, Achim; Stephan, Peter; Gambaryan-Roisman, Tatiana
2017-08-01
Chemical reactions in thin liquid films are found in many industrial applications, e.g., in combustion chambers of internal combustion engines where a fuel film can develop on pistons or cylinder walls. The reactions within the film and the turbulent outer gas flow influence film stability and lead to film breakup, which in turn can lead to deposit formation. In this work we examine the evolution and stability of a thin liquid film in the presence of a first-order chemical reaction and under the influence of a turbulent gas flow. Long-wave theory with a double perturbation analysis is used to reduce the complexity of the problem and obtain an evolution equation for the film thickness. The chemical reaction is assumed to be slow compared to film evolution and the amount of reactant in the film is limited, which means that the reaction rate decreases with time as the reactant is consumed. A linear stability analysis is performed to identify the influence of reaction parameters, material properties, and environmental conditions on the film stability limits. Results indicate that exothermic reactions have a stabilizing effect whereas endothermic reactions destabilize the film and can lead to rupture. It is shown that an initially unstable film can become stable with time as the reaction rate decreases. The shearing of the film by the external gas flow leads to the appearance of traveling waves. The shear stress magnitude has a nonmonotonic influence on film stability.
Ohta, Haruhiko; Ohno, Toshiyuki; Hioki, Fumiaki; Shinmoto, Yasuhisa
2004-11-01
A two-phase flow loop is a promising method for application to thermal management systems for large-scale space platforms handling large amounts of energy. Boiling heat transfer reduces the size and weight of cold plates. The transportation of latent heat reduces the mass flow rate of working fluid and pump power. To develop compact heat exchangers for the removal of waste heat from electronic devices with high heat generation density, experiments on a method to increase the critical heat flux for a narrow heated channel between parallel heated and unheated plates were conducted. Fine grooves are machined on the heating surface in a transverse direction to the flow and liquid is supplied underneath flattened bubbles by the capillary pressure difference from auxiliary liquid channels separated by porous metal plates from the main heated channel. The critical heat flux values for the present heated channel structure are more than twice those for a flat surface at gap sizes 2 mm and 0.7 mm. The validity of the present structure with auxiliary liquid channels is confirmed by experiments in which the liquid supply to the grooves is interrupted. The increment in the critical heat flux compared to those for a flat surface takes a maximum value at a certain flow rate of liquid supply to the heated channel. The increment is expected to become larger when the length of the heated channel is increased and/or the gravity level is reduced.
NASA Astrophysics Data System (ADS)
Deubelbeiss, Y.; McArdell, B. W.; Graf, C.
2011-12-01
The dynamics of a debris flow can be significantly influenced by erosion and deposition processes during an event because volume changes have a strong influence on flow properties such as flow velocity, flow heights and runout distances. It is therefore worth exploring how to include these processes in numerical models, which are used for hazard assessment and mitigation measure planning. However, it is still under debate, what mechanism drives the erosion of material at the base of a debris flow. There are different processes attributed to erosion: it has been proposed that erosion correlates with the stresses due to granular interactions at the front, which in turn strongly depend on particle size or it may be related to basal shear forces. Because it is expected that larger flow heights result in larger stresses one can additionally hypothesize that there is a correlation between erosion rate and flow height. To test different erosion laws in a numerical model and its influence on the flow behavior we implement different relationships and compare simulation results with field data. Herefore, we use the numerical model, RAMMS (Christen et al., 2010), employing the Voellmy-fluid friction law. While it has already been shown that a correlation of erosion with velocity does not lead to a satisfying result (too high entrainment in the tail) a correlation with flow height combined with velocity (momentum) has been successfully applied to ice-avalanches. Currently, we are testing the momentum-driven and for comparison we reconsider the simple velocity-driven erosion rate. However, these laws do not consider processes on a smaller scale such as particle fluctuations resulting in energy production, which might play an important role. Therefore, we additionally consider an erosion model that has potential to draw new insights on the erosion process in debris flows. The model is based on an extended Voellmy model, which additionally employs an equation, which is a measure of the random kinetic energy (RKE, equivalent to granular temperature) produced by the random movement of particles in a debris flow (Buser and Bartelt, 2009). Advantageous is that friction is dependent on the production of RKE and is decreasing with decreasing RKE. The amount of energy produced in the system, might therefore be a useful indicator for the erosion rate. While the erosion model using the Voellmy approach might be successfully applicable to cases where erosion and bulking are the main processes, such as in Illgraben (CH), it might be less straight forward in mountain torrents where we additionally observe a lot of deposition along the flow path such as in Dorfbach (CH). The extended Voellmy model is indirectly accounting for this process as friction is a function of RKE, which allows material to deposit earlier. At both locations we have debris flow observation stations including innovative new measurement techniques indication parameters such as flow velocity, height and volumes at specific locations (Illgraben, Dorfbach) as well as erosion rate measurements (Illgraben). These highly valuable data allow us good model calibration as well as verification of the newly implemented erosion models.
The Formation of Ethane from Carbon Dioxide under Cold Plasma
NASA Astrophysics Data System (ADS)
Zhang, Xiu-ling; Zhang, Lin; Dai, Bin; Gong, Wei-min; Liu, Chang-hou
2001-04-01
Pulsed-corona plasma has been used as a new method for ethane dehydrogenation at low temperature and normal pressure using carbon dioxide as an oxidant in this paper. The effect of carbon dioxide content in the feed, power input, and flow rate of the reactants on the ethane dehydrogenation has been investigated. The experimental results show that the conversion of ethane increases with the increase in the amount of carbon dioxide in the feed. The yield of ethylene and acetylene decreases with the increase in the yield of carbon monoxide, indicating that the increased carbon dioxide leads to the part of ethylene and acetylene being oxidized to carbon monoxide. Power input is primarily an electrical parameter in pulsed-corona plasma, which plays an important role in reactant conversion and product formation. When the power input reaches 16 W, ethane conversion is 41.0% and carbon dioxide conversion is 26.3%. The total yield of ethylene and acetylene is 15.6%. The reduced flow rate of feed improves the conversion of ethane, carbon dioxide and the yield of acetylene, and induces carbon deposit as well.
Modeling hydrodynamic effects on choanoflagellate feeding
NASA Astrophysics Data System (ADS)
Oakes, Christian; Hguyen, Hoa; Koehl, Mimi; Fauci, Lisa
2017-11-01
Choanoflagellates are unicellular organisms whose intriguing morphology includes a set of collars/microvilli emanating from the cell body, surrounding the beating flagellum. As the closest living relative to animals, they are important for both ecological and evolutionary studies. Choanoflagellates have three unicellular types: slow swimmers, fast swimmers, and thecate (attached to a surface by a stalk). Each has different morphology and feeding rate. We use the method of regularized Stokeslets to simulate cell-fluid interactions of each type and show the hydrodynamic effects on the amount and directions of fluid flow toward the collar. After validating the swimming speeds of our models with experimental data, we calculate the rate of flow across a capture zone around the collar (flux). This sheds light on how each morphological aspect of the cell aids in bacteria capture during feeding. Among the three types, the thecate cells have the largest average flux values, implying that they take advantage of the nearby surface by creating eddies that draw bacteria into their collar for ingestion. Funding Source: FASTER Grant SURF `` National Science Foundation DUE S-STEM Award 1153796, Mach Fellowship.
Venema, K.; van Berkel, W. J. H.; Korf, J.
2007-01-01
This report describes a versatile and robust microreactor for bioactive proteins physically immobilized on a polyether sulfone filter. The potential of the reactor is illustrated with glucose oxidase immobilized on a filter with a cut-off value of 30 kDa. A flow-injection system was used to deliver the reactants and the device was linked on-line to an electrochemical detector. The microreactor was used for on-line preparation of apoglucose oxidase in strong acid and its subsequent reactivation with flavin adenine dinucleotide. In addition we describe a miniaturized version of the microreactor used to assess several characteristics of femtomole to attomole amounts of glucose oxidase. A low negative potential over the electrodes was used when ferrocene was the mediator in combination with horseradish peroxidase, ensuring the absence of oxidation of electro-active compounds in biological fluids. A low backpressure at very low flow rates is an advantage, which increases the sensitivity. A variety of further applications of the microreactor are suggested. Figure Preparation of apoGOx and restoration of enzyme activity using a soluton of FAD PMID:17909761
Mathematical Modeling of Dual Layer Shell Type Recuperation System for Biogas Dehumidification
NASA Astrophysics Data System (ADS)
Gendelis, S.; Timuhins, A.; Laizans, A.; Bandeniece, L.
2015-12-01
The main aim of the current paper is to create a mathematical model for dual layer shell type recuperation system, which allows reducing the heat losses from the biomass digester and water amount in the biogas without any additional mechanical or chemical components. The idea of this system is to reduce the temperature of the outflowing gas by creating two-layered counter-flow heat exchanger around the walls of biogas digester, thus increasing a thermal resistance and the gas temperature, resulting in a condensation on a colder surface. Complex mathematical model, including surface condensation, is developed for this type of biogas dehumidifier and the parameter study is carried out for a wide range of parameters. The model is reduced to 1D case to make numerical calculations faster. It is shown that latent heat of condensation is very important for the total heat balance and the condensation rate is highly dependent on insulation between layers and outside temperature. Modelling results allow finding optimal geometrical parameters for the known gas flow and predicting the condensation rate for different system setups and seasons.
Makarov, Alexey A; Schafer, Wes A; Helmy, Roy
2015-02-17
The market of protein therapeutics is exploding, and characterization methods for proteins are being further developed to understand and explore conformational structures with regards to function and activity. There are several spectroscopic techniques that allow for analyzing protein secondary structure in solution. However, a majority of these techniques need to use purified protein, concentrated enough in the solution to produce a relevant spectrum. In this study, we describe a novel approach which uses ultrahigh pressure liquid chromatography (UHPLC) coupled with mass-spectrometry (MS) to explore compressibility of the secondary structure of proteins under increasing pressure detected by hydrogen-deuterium exchange (HDX). Several model proteins were used for these studies. The studies were conducted with UHPLC in isocratic mode at constant flow rate and temperature. The pressure was modified by a backpressure regulator up to about 1200 bar. It was found that the increase of retention factors upon pressure increase, at constant flow rate and temperature, was based on reduction of the proteins' molecular molar volume. The change in the proteins' molecular molar volume was caused by changes in protein folding, as was revealed by differential deuterium exchange. The degree of protein folding under certain UHPLC conditions can be controlled by pressure, at constant temperature and flow rate. By modifying pressure during UHPLC separation, it was possible to achieve changes in protein folding, which were manifested as changes in the number of labile protons exchanged to deuterons, or vice versa. Moreover, it was demonstrated with bovine insulin that a small difference in the number of protons exchanged to deuterons (based on protein folding under pressure) could be observed between batches obtained from different sources. The use of HDX during UHPLC separation allowed one to examine protein folding by pressure at constant flow rate and temperature in a mixture of sample solution with minimal amounts of sample used for analysis.
Abadelah, Mohamad; Chrystyn, Henry; Bagherisadeghi, Golshan; Abdalla, Gaballa; Larhrib, Hassan
2018-01-01
Onbrez Breezhaler® is a low-resistance capsule-based device that was developed to deliver indacaterol maleate. The study was designed to investigate the effects of both maximum flow rate (MIF) and inhalation volume (Vin) on the dose emission of indacaterol 150 and 300 μg dose strengths after one and two inhalations using dose unit sampling apparatus (DUSA) as well as to study the aerodynamic characteristics of indacaterol Breezhaler® using the Andersen cascade impactor (ACI) at a different set of MIF and Vin. Indacaterol 150 and 300 μg contain equal amounts of lactose per carrier. However, 150 μg has the smallest carrier size. The particle size distribution (PSD) of indacaterol DPI formulations 150 and 300 μg showed that the density of fine particles increased with the increase of the primary pressure. For both strengths (150 μg and 300 μg), ED1 increased and ED2 decreased when the inhalation flow rate and inhaled volume increased. The reduction in ED1 and subsequent increase in ED2 was such that when the Vin is greater than 1 L, then 60 L/min could be regarded as the minimum MIF. The Breezhaler was effective in producing respirable particles with an MMAD ≤5 μm irrespective of the inhalation flow rate, but the mass fraction of particles with an aerodynamic diameter <3 μm is more pronounced between 60 and 90 L/min. The dose emission of indacaterol was comparable for both dose strengths 150 and 300 μg. These in vitro results suggest that a minimum MIF of 60 L/min is required during routine use of Onbrez Breezhaler®, and confirm the good practice to make two separate inhalations from the same dose.
Theory for source-responsive and free-surface film modeling of unsaturated flow
Nimmo, J.R.
2010-01-01
A new model explicitly incorporates the possibility of rapid response, across significant distance, to substantial water input. It is useful for unsaturated flow processes that are not inherently diffusive, or that do not progress through a series of equilibrium states. The term source-responsive is used to mean that flow responds sensitively to changing conditions at the source of water input (e.g., rainfall, irrigation, or ponded infiltration). The domain of preferential flow can be conceptualized as laminar flow in free-surface films along the walls of pores. These films may be considered to have uniform thickness, as suggested by field evidence that preferential flow moves at an approximately uniform rate when generated by a continuous and ample water supply. An effective facial area per unit volume quantitatively characterizes the medium with respect to source-responsive flow. A flow-intensity factor dependent on conditions within the medium represents the amount of source-responsive flow at a given time and position. Laminar flow theory provides relations for the velocity and thickness of flowing source-responsive films. Combination with the Darcy-Buckingham law and the continuity equation leads to expressions for both fluxes and dynamic water contents. Where preferential flow is sometimes or always significant, the interactive combination of source-responsive and diffuse flow has the potential to improve prediction of unsaturated-zone fluxes in response to hydraulic inputs and the evolving distribution of soil moisture. Examples for which this approach is efficient and physically plausible include (i) rainstorm-generated rapid fluctuations of a deep water table and (ii) space- and time-dependent soil water content response to infiltration in a macroporous soil. ?? Soil Science Society of America.
40 CFR 1065.545 - Validation of proportional flow control for batch sampling.
Code of Federal Regulations, 2010 CFR
2010-07-01
... of the estimate, SEE, of the sample flow rate versus the total flow rate. For each test interval, demonstrate that SEE was less than or equal to 3.5% of the mean sample flow rate. (b) For any pair of flow meters, use recorded sample and total flow rates, where total flow rate means the raw exhaust flow rate...
Ahn, Tai Sang; Lee, Jung-Phil; Kim, Juhyun; Oh, Seaung Youl; Chun, Myung-Kwan; Choi, Hoo-Kyun
2013-11-01
The purpose of this study was to investigate characteristics of transungual drug delivery and the feasibility of developing a drug-in-adhesive formulation of terbinafine. The permeation of terbinafine from a PSA matrix across porcine hoof membrane was determined using a plate containing poloxamer gel. The permeation rate of terbinafine across hairless mouse skin was evaluated using a flow-through diffusion cell system. The permeation of terbinafine across the hoof membranes was the highest from the silicone adhesive matrix, followed by PIB, and most of the acrylic adhesives, SIS, and SBS. The rank order of permeation rate across mice skin was different from the rank order across porcine hooves. The amount of terbinafine permeated across the porcine hoof membranes poorly correlated with the amount of terbinafine remaining inside the hooves after 20 days, however, the ratio between rate of terbinafine partitioning into the hoof membrane and its rate of diffusion across the membrane was relatively constant within the same type of PSA. For influence of various vehicles in enhancing permeation of terbinafine across the hoof membrane, all vehicles except Labrasol(®) showed tendency to improve permeation rate. However, the enhancement ratio of a given vehicle differed from one adhesive to another with a moderate correlation between them. The infrared spectrum of the hoof treated with NMP, PPG 400 or PEG 200 indicated that the conformation of keratin changed from a non-helical to a helical structure.
Tejada-Casado, Carmen; Lara, Francisco J; García-Campaña, Ana M; Del Olmo-Iruela, Monsalud
2018-03-30
Ultra-high performance liquid chromatography (UHPLC) coupled with fluorescence detection (FL) has been proposed for the first time to determine thirteen benzimidazoles (BZs) in farmed fish samples. In order to optimize the chromatographic separation, parameters such as mobile phase composition and flow rate were carefully studied, establishing a gradient mode with a mobile phase consisted of water (solvent A) and acetonitrile (solvent B) at a flow rate of 0.4 mL/min. The separation was performed on a Zorbax Eclipse Plus RRHD C 18 column (50 × 2.1 mm, 1.8 μm), involving a total analysis time lower than 12 min. Salting-out assisted liquid-liquid extraction (SALLE) was applied as sample treatment to different types of farmed fish (trout, sea bream and sea bass). To obtain satisfactory extraction efficiencies for the studied analytes, several parameters affecting the SALLE procedure were optimized including the amount of sample, type and volume of the extraction solvent, and the nature and amount of the salt used. Characterization of the method in terms of performance characteristics was carried out, obtaining satisfactory results for the linearity (R 2 ≥ 0.997), repeatability (RSD ≤ 6.1%), reproducibility (RSD ≤ 10.8%) and recoveries (R ≥ 79%; RSD ≤ 7.8%). Detection limits between 0.04-29.9 μg kg -1 were obtained, demonstrating the applicability of this fast, simple and environmentally friendly method. Copyright © 2018 Elsevier B.V. All rights reserved.
Pico-CSIA: Picomolar Scale Compound-Specific Isotope Analyses
NASA Astrophysics Data System (ADS)
Baczynski, A. A.; Polissar, P. J.; Juchelka, D.; Schwieters, J. B.; Hilkert, A.; Freeman, K. H.
2016-12-01
The basic approach to analyzing molecular isotopes has remained largely unchanged since the late 1990s. Conventional compound-specific isotope analyses (CSIA) are conducted using capillary gas chromatography (GC), a combustion interface, and an isotope-ratio mass spectrometer (IRMS). Commercially available GC-IRMS systems are comprised of components with inner diameters ≥0.25 mm and employ helium flow rates of 1-4 mL/min. These flow rates are an order of magnitude larger than what the IRMS can accept. Consequently, ≥90% of the sample is lost through the open split, and 1-10s of nanomoles of carbon are required for analysis. These sample requirements are prohibitive for many biomarkers, which are often present in picomolar concentrations. We utilize the resolving power and low flows of narrow-bore capillary GC to improve the sensitivity of CSIA. Narrow bore capillary columns (<0.25 mm ID) allow low helium flow rates of ≤0.5mL/min for more efficient sample transfer to the ion source of the IRMS while maintaining the high linear flow rates necessary to preserve narrow peak widths ( 250 ms). The IRMS has been fitted with collector amplifiers configured to 25 ms response times for rapid data acquisition across narrow peaks. Previous authors (e.g., Sacks et al., 2007) successfully demonstrated improved sensitivity afforded by narrow-bore GC columns. They reported an accuracy and precision of 1.4‰ for peaks with an average width at half maximum of 720 ms for 100 picomoles of carbon on column. Our method builds on their advances and further reduces peak widths ( 600 ms) and the amount of sample lost prior to isotopic analysis. Preliminary experiments with 100 picomoles of carbon on column show an accuracy and standard deviation <1‰. With further improvement, we hope to demonstrate robust isotopic analysis of 10s of picomoles of carbon, more than 2 orders of magnitude lower than commercial systems. The pico-CSIA method affords high-precision isotopic analyses for picomoles of carbon in organic biomarkers, which significantly lowers sample size requirements and broadens analytical windows in paleoclimate, astrobiological, and biogeochemical research.
NASA Astrophysics Data System (ADS)
Vona, A.; Di Piazza, A.; Romano, C.; De Astis, G.; Soto, G. J.
2014-12-01
We present a study of high-temperature, uniaxial deformation experiments of natural magma from an andesitic eruption of Turrialba volcano (1.9ka Plinian eruption). The aim of this work is to investigate the multiphase rheology (liquid+vesicles+crystals) of natural samples and the effect of vesicles and crystals on the magma viscosity. The experiments were performed using a high-temperature uniaxial Geocomp LoadTrac II press at dry atmospheric conditions and controlled deformation rates. Cores of natural sample (with Φcrys=0.20-0.30 and Φves=0.41-0.58) were deformed isothermally (790-870°C) at variable strain rates (VSR, from 10-6 to 10-4 s-1) and constant strain rate (CSR, 10-5 s-1). VSR were performed at low total amount of strain (e<0.10) to parameterize the flow behavior of these complex natural materials. The stress-strain rate relationships under flow conditions showed a linear trend between the applied stress and strain rate in the temperature interval investigated. All the samples display a steep linear trend, typical of Newtonian fluids (n index ~ 1), with a very small shear thinning behavior. CSR tests were performed at different total amount of strain (e=0.15-0.25-0.35). Strain hardening was observed with increasing deformation, resulting in an increase of apparent viscosity (up to 100.5 Pa s). This increase is related to the loss of total porosity (up to ΔΦves=0.15) due to compaction of the sample as indicated by post-run analyses . The measured multiphase rheology of Turrialba magmas was compared with literature models for both crystal- and bubble-bearing suspension. We calculate a difference of ~101 Pa s in magma apparent viscosity between high and low density samples, that coupled with a lateral temperature gradient inside the conduit of the volcano, could increase up to ~103 Pa s. The large difference in viscosity could be responsible of significant rheological contrasts, possibly resulting in strain localization and brittle fragmentation of magma.
NASA Astrophysics Data System (ADS)
Leung, V.; Montgomery, D. R.
2010-12-01
The interactions between woody debris, fluid flow and sediment transport in rivers play a fundamental role in ecogeomorphology, affecting channel roughness, streambed morphology, and sediment transport and storage. In particular, woody debris increases the hydraulic and topographic complexity in rivers, leading to a greater diversity of aquatic habitats and an increase in the number of large pools that are important fish habitat and breeding grounds. In the past decade, engineered logjams have become an increasingly used tool in river management for simultaneously decreasing the rate of riverbank migration and improving aquatic habitat. Sediment deposits around woody debris build up riverbanks and counteract bank migration caused by erosion. Previous experiments of flow visualization around model woody debris suggest the amount of sediment scour and deposition are primarily related to the presence of roots and the obstructional area of the woody debris. We present the results of field surveys and sediment transport experiments of streambed morphology around stationary woody debris on a mobile bed. These experiments test the effects of root presence, root geometry and log orientation of individual stationary trees on streambed morphology. The flume contains a deformable sediment bed of medium sand, and has subcritical and turbulent flow, corresponding to flow conditions found in nature. Field surveys on the Hoh River, WA, measure the local streambed morphology around woody debris (e.g. pool and gravel-bar length, width and depth), as well as woody debris characteristics (e.g. tree diameter, tree length, root diameter and root depth). We quantified the amount of local sediment scour and deposition around woody debris of varying sizes, geometries and orientations relative to flow. We find that: 1) the presence of roots on woody debris leads to greater areas of both sediment scour and deposition; and 2) the amount of sediment scour and deposition are related to the root cross-sectional area, oriented orthogonal to flow. Sediment transport around woody debris is episodic and occurs during flood events, making it difficult to take active measurements. A combined methodology of flume experiments and fieldwork allows for a general understanding of sediment transport around woody debris that includes the complexities of natural systems. A better understanding of the underlying sediment physics and hydraulics around naturally occurring woody debris in rivers can provide guidance and criteria for use in river restoration and engineering as well as scientific insights into a complex interdisciplinary problem.
NASA Astrophysics Data System (ADS)
Kakran, Mitali; Sahoo, Nanda Gopal; Tan, I.-Lin; Li, Lin
2012-03-01
The objective of this study was to enhance the solubility and dissolution rate of a poorly water-soluble antioxidant, curcumin, by fabricating its nanoparticles with two methods: antisolvent precipitation with a syringe pump (APSP) and evaporative precipitation of nanosuspension (EPN). For APSP, process parameters like flow rate, stirring speed, solvent to antisolvent (SAS) ratio, and drug concentration were investigated to obtain the smallest particle size. For EPN, factors like drug concentration and the SAS ratio were examined. The effects of these process parameters on the supersaturation, nucleation, and growth rate were studied and optimized to obtain the smallest particle size of curcumin by both the methods. The average particle size of the original drug was about 10-12 μm and it was decreased to a mean diameter of 330 nm for the APSP method and to 150 nm for the EPN method. Overall, decreasing the drug concentration or increasing the flow rate, stirring rate, and antisolvent amount resulted in smaller particle sizes. Differential scanning calorimetry studies suggested lower crystallinity of curcumin particles fabricated. The solubility and dissolution rates of the prepared curcumin particles were significantly higher than those the original curcumin. The antioxidant activity, studied by the DPPH free radical-scavenging assay, was greater for the curcumin nanoparticles than the original curcumin. This study demonstrated that both the methods can successfully prepare curcumin into submicro to nanoparticles. However, drug particles prepared by EPN were smaller than those by APSP and hence, showed the slightly better solubility, dissolution rate, and antioxidant activity than the latter.
NASA Astrophysics Data System (ADS)
Krekeler, Mark P. S.; Probst, Pete; Samsonov, Misha; Tselepis, Cynthia M.; Bates, William; Kearns, Lance E.; Maynard, J. Barry
2007-12-01
Subsurface flow constructed wetlands in the village of Akumal, Quintana Roo, Mexico were surveyed to determine the general status of the wetland systems and provide baseline information for long term monitoring and further study. Twenty subsurface flow wetlands were surveyed and common problems observed in the systems were overloading, poor plant cover, odor, and no secondary containment. Bulk mineral composition of aggregate from two subsurface flow constructed wetlands was determined to consist solely of calcite using bulk powder X-ray diffraction. Some soil structure is developed in the aggregate and aggregate levels in wetlands drop at an estimated rate between 3 and 10 cm/year for overloaded wetlands owing to dissolution. Mineral composition from fresh aggregate samples commonly is a mixture of calcite and aragonite. Trace amounts of Pb, Zn, Co, and Cr were observed in fresh aggregate. Coefficients of permeability ( k) varied from 0.006 to 0.027 cm/s with an average values being 0.016 cm/s. Grain size analysis of fresh aggregate samples indicates there are unimodal and multimodal size distributions in the samples with modes in the coarse and fine sand being common. Investigations of other geologic media from the Reforma region indicate that a dolomite with minor amounts of Fe-oxide and palygorskite is abundant and may be a better aggregate source that the current materials used. A Ca-montmorillonite bed was identified in the Reforma region as well and this unit is suitable to serve as a clay liner to prevent leaks for new and existing wetland systems. These newly discovered geologic resources should aid in the improvement of subsurface flow constructed wetlands in the region. Although problems do exist in these wetlands with respect to design, these systems represent a successful implementation of constructed wetlands at a community level in developing regions.
NASA Astrophysics Data System (ADS)
Fox, A.; Packman, A. I.; Preziosi-Ribero, A.; Li, A.; Arnon, S.
2017-12-01
Sediment transport and deposition in streams can affect streambed hydraulic characteristics due to clogging, reduce water fluxes through the hyporheic zone, and thus expected to affect biogeochemical processes. Processes affecting deposition of suspended particles were systematically studied under various overlying velocities but without taking into account the interactions with groundwater. This is despite the fact that the interaction with groundwater were shown to play an important role in deposition patterns of fine sediments in field studies. The objective of this study was to evaluate the effect of losing and gaining fluxes on suspended sediment depositional patterns and on hyporheic exchange fluxes. Experiments were conducted in a laboratory flume system (640 cm long and 30 cm wide) that has a capacity to enforce losing or gaining flow conditions. The flume was packed with homogenous sand, while suspended sediment deposition was evaluated by adding kaolinite particles to the water and following the deposition rate by particle disappearance from the bulk water. Consecutive additions of kaolinite were done, while hyporheic exchange fluxes were evaluated by conducting NaCl tracer experiments between each kaolinite additions. Furthermore, dye injections were used to visualize the flow patterns in the streambed using time-lapse photography through the transparent sidewalls of the flume. Hyporheic exchange and particle tracking simulations were done to assess the results of particle deposition and feedbacks between hyporheic flow, particle transport, and streambed clogging. Experimental results showed that the deposition of clay decreases with increasing amount of clay concentration in the sediment. Hyporheic exchange flux decreases linearly with increasing amount of clay added to the system and the region of active hyporheic exchange was confined to the upper part of the sediment. Understanding the particle deposition mechanisms under losing and gaining flow condition are expected to improve our predictive ability to capture the dynamics of streambed characteristics, which has implications to sediment transport, biogeochemical processes and hyporheic ecology.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Praphairaksit, Narong
2000-09-12
An externally air-cooled low-flow torch has been constructed and successfully demonstrated for applications in inductively coupled plasma mass spectrometry (ICP-MS). The torch is cooled by pressurized air flowing at ~70 L/min through a quartz air jacket onto the exterior of the outer tube. The outer gas flow rate and operating RF forward power are reduced considerably. Although plasmas can be sustained at the operating power as low as 400 W with a 2 L/min of outer gas flow, somewhat higher power and outer gas flows are advisable. A stable and analytical useful plasma can be obtained at 850 W withmore » an outer gas flow rate of ~4 L/min. Under these conditions, the air-cooled plasma produces comparable sensitivities, doubly charged ion ratios, matrix effects and other analytical merits as those produced by a conventional torch while using significantly less argon and power requirements. Metal oxide ion ratios are slightly higher with the air-cooled plasma but can be mitigated by reducing the aerosol gas flow rate slightly with only minor sacrifice in analyte sensitivity. A methodology to alleviate the space charge and matrix effects in ICP-MS has been developed. A supplemental electron source adapted from a conventional electron impact ionizer is added to the base of the skimmer. Electrons supplied from this source downstream of the skimmer with suitable amount and energy can neutralize the positive ions in the beam extracted from the plasma and diminish the space charge repulsion between them. As a result, the overall ion transmission efficiency and consequent analyte ion sensitivities are significantly improved while other important analytical aspects, such as metal oxide ion ratio, doubly charged ion ratio and background ions remain relatively unchanged with the operation of this electron source. This technique not only improves the ion transmission efficiency but also minimizes the matrix effects drastically. The matrix-induced suppression of signal for even the most troublesome combination of light analyte and heavy matrix elements can be attenuated from 90-99% to only 2-10% for 2 mM matrix solutions with an ultrasonic nebulizer. The supplemental electron current can be adjusted to ''titrate'' out the matrix effects as desired.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bartlome, Richard, E-mail: richard.bartlome@alumni.ethz.ch; De Wolf, Stefaan; Demaurex, Bénédicte
2015-05-28
We clarify the difference between the SiH{sub 4} consumption efficiency η and the SiH{sub 4} depletion fraction D, as measured in the pumping line and the actual reactor of an industrial plasma-enhanced chemical vapor deposition system. In the absence of significant polysilane and powder formation, η is proportional to the film growth rate. Above a certain powder formation threshold, any additional amount of SiH{sub 4} consumed translates into increased powder formation rather than into a faster growing Si film. In order to discuss a zero-dimensional analytical model and a two-dimensional numerical model, we measure η as a function of themore » radio frequency (RF) power density coupled into the plasma, the total gas flow rate, the input SiH{sub 4} concentration, and the reactor pressure. The adjunction of a small trimethylboron flow rate increases η and reduces the formation of powder, while the adjunction of a small disilane flow rate decreases η and favors the formation of powder. Unlike η, D is a location-dependent quantity. It is related to the SiH{sub 4} concentration in the plasma c{sub p}, and to the phase of the growing Si film, whether the substrate is glass or a c-Si wafer. In order to investigate transient effects due to the RF matching, the precoating of reactor walls, or the introduction of a purifier in the gas line, we measure the gas residence time and acquire time-resolved SiH{sub 4} density measurements throughout the ignition and the termination of a plasma.« less
Therapeutic plasma exchange: a paired comparison of Fresenius AS104 vs. COBE Spectra.
Burgstaler, E A; Pineda, A A
2001-01-01
For therapeutic plasma exchange (TPE), continuous flow separators are known to be efficient as exemplified by Fresenius AS104 and COBE Spectra. The AS104 uses an interface monitoring system in the centrifuge during TPE, whereas Spectra uses computer algorithms to establish the plasma-cell interface. To determine the plasma collection efficiency (PLCE), anticoagulant (AC) volumes used, and platelets (PLT) lost of the AS104 and the Spectra, we performed a prospective paired comparison of 20 TPE (each machine). The study included 17 patients, 1.3 plasma volume exchanges (without AC), equal inlet rates, and AC ratio of 13:1. Processing times did not include reinfuse mode. Platelet loss was determined by sampling the collection bags. Inlet rates were between 60-110 ml/min. Diagnosis included peripheral neuropathies, TTP and cryoglobulinemia. The AS104 had significantly (P<0.0001) lower average whole blood processed (F:6,601 vs. S:8,584 ml), AC volume (F:532 vs. S:719 ml), and processing time (F:80 vs. S:102 minutes) than Spectra. The AS104 had significantly (P<0.0001) higher average plasma flow rates (F:53 vs. S:44 ml/minute), plasma collection efficiency (F:90 vs. S:69%), and platelet loss (F:2.0 vs. S:0.14 x 10(11) plt) than Spectra. Platelet loss correlated with inlet flow rate with the AS104 but not with the Spectra. The AS104 has a significantly higher collection efficiency than Spectra allowing it to remove the same amount of plasma in significantly less time, by processing significantly less blood, using significantly less AC, but removing significantly more platelets than Spectra. Copyright 2001 Wiley-Liss, Inc.
Modelling the effects of cerebral microvasculature morphology on oxygen transport.
Park, Chang Sub; Payne, Stephen J
2016-01-01
The cerebral microvasculature plays a vital role in adequately supplying blood to the brain. Determining the health of the cerebral microvasculature is important during pathological conditions, such as stroke and dementia. Recent studies have shown the complex relationship between cerebral metabolic rate and transit time distribution, the transit times of all the possible pathways available dependent on network topology. In this paper, we extend a recently developed technique to solve for residue function, the amount of tracer left in the vasculature at any time, and transit time distribution in an existing model of the cerebral microvasculature to calculate cerebral metabolism. We present the mathematical theory needed to solve for oxygen concentration followed by results of the simulations. It is found that oxygen extraction fraction, the fraction of oxygen removed from the blood in the capillary network by the tissue, and cerebral metabolic rate are dependent on both mean and heterogeneity of the transit time distribution. For changes in cerebral blood flow, a positive correlation can be observed between mean transit time and oxygen extraction fraction, and a negative correlation between mean transit time and metabolic rate of oxygen. A negative correlation can also be observed between transit time heterogeneity and the metabolic rate of oxygen for a constant cerebral blood flow. A sensitivity analysis on the mean and heterogeneity of the transit time distribution was able to quantify their respective contributions to oxygen extraction fraction and metabolic rate of oxygen. Mean transit time has a greater contribution than the heterogeneity for oxygen extraction fraction. This is found to be opposite for metabolic rate of oxygen. These results provide information on the role of the cerebral microvasculature and its effects on flow and metabolism. They thus open up the possibility of obtaining additional valuable clinical information for diagnosing and treating cerebrovascular diseases. Copyright © 2015. Published by Elsevier Ltd.
NASA Astrophysics Data System (ADS)
Yang, Ce; Wang, Yingjun; Lao, Dazhong; Tong, Ding; Wei, Longyu; Liu, Yixiong
2016-08-01
The inlet recirculation characteristics of double suction centrifugal compressor with unsymmetrical inlet structures were studied in numerical method, mainly focused on three issues including the amounts and differences of the inlet recirculation in different working conditions, the circumferential non-uniform distributions of the inlet recirculation, the recirculation velocity distributions of the upstream slot of the rear impeller. The results show that there are some differences between the recirculation of the front impeller and that of the rear impeller in whole working conditions. In design speed, the recirculation flow rate of the rear impeller is larger than that of the front impeller in the large flow range, but in the small flow range, the recirculation flow rate of the rear impeller is smaller than that of the front impeller. In different working conditions, the recirculation velocity distributions of the front and rear impeller are non-uniform along the circumferential direction and their non-uniform extents are quite different. The circumferential non-uniform extent of the recirculation velocity varies with the working conditions change. The circumferential non-uniform extent of the recirculation velocity of front impeller and its distribution are determined by the static pressure distribution of the front impeller, but that of the rear impeller is decided by the coupling effects of the inlet flow distortion of the rear impeller, the circumferential unsymmetrical distribution of the upstream slot and the asymmetric structure of the volute. In the design flow and small flow conditions, the recirculation velocities at different circumferential positions of the mean line of the upstream slot cross-section of the rear impeller are quite different, and the recirculation velocities distribution forms at both sides of the mean line are different. The recirculation velocity distributions in the cross-section of the upstream slot depend on the static pressure distributions in the intake duct.
NASA Astrophysics Data System (ADS)
Zaihua, Liu; Svensson, U.; Dreybrodt, W.; Daoxian, Yuan; Buhmann, D.
1995-08-01
Hydrochemical and hydrodynamical investigations are presented to explain tufa deposition rates along the flow path of the Huanglong Ravine, located in northwestern Sichuan province, China, on an altitude of about 3400 m asl. Due to outgassing of CO 2 the mainly spring-fed stream exhibits, along a valley of 3.5 km, calcite precipitation rates up to a few mm/year. We have carried out in situ experiments to measure calcite deposition rates at rimstone dams, inside of pools and in the stream-bed. Simultaneously, the downstream evolution of water chemistry was investigated at nine locations with respect to Ca 2+, Mg 2+, Na +, Cl -, SO 42-, and alkalinity. Temperature, pH, and conductivity were measured in situ, while total hardness, Ca T, and alkalinity have been determined immediately after sampling, performing standard titration methods. The water turned out to be of an almost pure CaMgHCO 3 type. The degassing of CO 2 causes high supersaturation with respect to calcite and due to calcite precipitation the Ca 2+ concentration decreases from 6·10 -3 mole/1 upstream down to 2.5·10 -3 mole/1 at the lower course. Small rectangular shaped tablets of pure marble were mounted under different flow regimes, i.e., at the dam sites with fast water flow as well as inside pools with still water. After the substrate samples had stayed in the water for a period of a few days, the deposition rates were measured by weight increase, up to several tens of milligrams. Although there were no differences in hydrochemistry, deposition rates in fast flowing water were higher by as much as a factor of four compared to still water, indicating a strong influence of hydrodynamics. While upstream rates amounted up to 5 mm/year, lower rates of about 1 mm/year were observed downstream. Inspection of the marble substrate surfaces by EDAX and SEM (scanning electron microscope) revealed authigeneously grown calcite crystals of about 10 μm. Their shape and habit are indicative of a chemically controlled inorganic origin. By applying a mass transfer model for calcite precipitation taking into account the reaction rates at the surface given by Plummer et al. (1978), slow conversion of CO 2 into H + and HCO 3- , and diffusional mass transport across a diffusion boundary layer, we have calculated the deposition rates from the hydrochemistry of the corresponding locations. The calculated rates agree within a factor of two with the experimental results. Our findings confirm former conclusions with respect to fast flow conditions: reasonable rates of calcite precipitation can be estimated in reducing the PWP-rate calculated from the chemical composition of the water by a factor of about ten, thus correcting for the influence of the diffusion boundary layer.
Foliar Water Uptake of Tamarix ramosissima from an Atmosphere of High Humidity
Li, Shuang; Xiao, Hong-lang; Zhao, Liang; Zhou, Mao-Xian; Wang, Fang
2014-01-01
Many species have been found to be capable of foliar water uptake, but little research has focused on this in desert plants. Tamarix ramosissima was investigated to determine whether its leaves can directly absorb water from high humidity atmosphere and, if they can, to understand the magnitude and importance of foliar water uptake. Various techniques were adopted to demonstrate foliar water uptake under submergence or high atmospheric humidity. The mean increase in leaf water content after submergence was 29.38% and 20.93% for mature and tender leaves, respectively. In the chamber experiment, obvious reverse sap flow occurred when relative humidity (RH) was persistently above 90%. Reverse flow was recorded first in twigs, then in branches and stems. For the stem, the percentage of negative sap flow rate accounting for the maximum value of sap flow reached 10.71%, and its amount accounted for 7.54% of diurnal sap flow. Small rainfall can not only compensate water loss of plant by foliar uptake, but also suppress transpiration. Foliar uptake can appear in the daytime under certain rainfall events. High atmospheric humidity is beneficial for enhancing the water status of plants. Foliar uptake should be an important strategy of water acquisition for desert plants. PMID:24982964
Focazio, M.J.; Speiran, G.K.
1993-01-01
The groundwater-flow system of the Virginia Coastal Plain consists of areally extensive and interconnected aquifers. Large, regionally coalescing cones of depression that are caused by large withdrawals of water are found in these aquifers. Local groundwater systems are affected by regional pumping, because of the interactions within the system of aquifers. Accordingly, these local systems are affected by regional groundwater flow and by spatial and temporal differences in withdrawals by various users. A geographic- information system was used to refine a regional groundwater-flow model around selected withdrawal centers. A method was developed in which drawdown maps that were simulated by the regional groundwater-flow model and the principle of superposition could be used to estimate drawdown at local sites. The method was applied to create drawdown maps in the Brightseat/Upper Potomac Aquifer for periods of 3, 6, 9, and 12 months for Chesapeake, Newport News, Norfolk, Portsmouth, Suffolk, and Virginia Beach, Virginia. Withdrawal rates were supplied by the individual localities and remained constant for each simulation period. This provides an efficient method by which the individual local groundwater users can determine the amount of drawdown produced by their wells in a groundwater system that is a water source for multiple users and that is affected by regional-flow systems.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crabtree, G. W.; Lewis, N. S.; Materials Science Division
2007-03-01
The Sun provides Earth with a staggering amount of energy - enough to power the great oceanic and atmospheric currents, the cycle of evaporation and condensation that brings fresh water inland and drives river flow, and the typhoons, hurricanes, and tornadoes that so easily destroy the natural and built landscape. The San Francisco earthquake of 1906, with magnitude 7.8, released an estimated 10{sup 17} joules of energy, the amount the Sun delivers to Earth in one second. Earth's ultimate recoverable resource of oil, estimated at 3 trillion barrels, contains 1.7 x 10{sup 22} joules of energy, which the Sun suppliesmore » to Earth in 1.5 days. The amount of energy humans use annually, about 4.6 x 10{sup 20} joules, is delivered to Earth by the Sun in one hour. The enormous power that the Sun continuously delivers to Earth, 1.2 x 10{sup 5} terawatts, dwarfs every other energy source, renewable or nonrenewable. It dramatically exceeds the rate at which human civilization produces and uses energy, currently about 13 TW.« less
Discovering cell types in flow cytometry data with random matrix theory
NASA Astrophysics Data System (ADS)
Shen, Yang; Nussenblatt, Robert; Losert, Wolfgang
Flow cytometry is a widely used experimental technique in immunology research. During the experiments, peripheral blood mononuclear cells (PBMC) from a single patient, labeled with multiple fluorescent stains that bind to different proteins, are illuminated by a laser. The intensity of each stain on a single cell is recorded and reflects the amount of protein expressed by that cell. The data analysis focuses on identifying specific cell types related to a disease. Different cell types can be identified by the type and amount of protein they express. To date, this has most often been done manually by labelling a protein as expressed or not while ignoring the amount of expression. Using a cross correlation matrix of stain intensities, which contains both information on the proteins expressed and their amount, has been largely ignored by researchers as it suffers from measurement noise. Here we present an algorithm to identify cell types in flow cytometry data which uses random matrix theory (RMT) to reduce noise in a cross correlation matrix. We demonstrate our method using a published flow cytometry data set. Compared with previous analysis techniques, we were able to rediscover relevant cell types in an automatic way. Department of Physics, University of Maryland, College Park, MD 20742.
Fast packet switching algorithms for dynamic resource control over ATM networks
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tsang, R.P.; Keattihananant, P.; Chang, T.
1996-12-01
Real-time continuous media traffic, such as digital video and audio, is expected to comprise a large percentage of the network load on future high speed packet switch networks such as ATM. A major feature which distinguishes high speed networks from traditional slower speed networks is the large amount of data the network must process very quickly. For efficient network usage, traffic control mechanisms are essential. Currently, most mechanisms for traffic control (such as flow control) have centered on the support of Available Bit Rate (ABR), i.e., non real-time, traffic. With regard to ATM, for ABR traffic, two major types ofmore » schemes which have been proposed are rate- control and credit-control schemes. Neither of these schemes are directly applicable to Real-time Variable Bit Rate (VBR) traffic such as continuous media traffic. Traffic control for continuous media traffic is an inherently difficult problem due to the time- sensitive nature of the traffic and its unpredictable burstiness. In this study, we present a scheme which controls traffic by dynamically allocating/de- allocating resources among competing VCs based upon their real-time requirements. This scheme incorporates a form of rate- control, real-time burst-level scheduling and link-link flow control. We show analytically potential performance improvements of our rate- control scheme and present a scheme for buffer dimensioning. We also present simulation results of our schemes and discuss the tradeoffs inherent in maintaining high network utilization and statistically guaranteeing many users` Quality of Service.« less
E. coli Resuspension During an Artificial High-flow Event in a Small First-order Creek
NASA Astrophysics Data System (ADS)
Pachepsky, Y. A.; Guber, A. K.; Shelton, D. R.; Hill, R. L.
2009-04-01
Stream, pond, and lake sediments can serve as environmental reservoirs for E. coli, including pathogenic strains. Substantial increases in E. coli concentrations observed in stream water during rainfall events are often attributed exclusively to runoff from agricultural fields, pastures, and riparian areas. However, this increase can, to various extents, be caused by the resuspension of E. coli from sediment. The separation of runoff vs. sediment E. coli sources is not possible based exclusively on creek water sampling during natural rainfalls. The objectives of this work were (a) to create and monitor an artificial high-flow event that would cause E. coli concentration changes solely due to resuspension and settling, (b) to develop a model of E. coli transport in creek water as affected by resuspension and settling. The study site, at the USDA-Beltsville Agricultural Research Center, is in the mid-Atlantic coastal plain of Maryland. The site contains a small first-order stream that is instrumented with four stations for monitoring stream flow and bacteria concentrations. The creek runs within a riparian corridor of variable width from about 65 m at its narrowest point, to more than 100 m. The creek bed is from 100 to 150 cm wide. Prior to the high-flow experiment, the creek sediment was grab-sampled weekly for 2 months for E. coli concentrations at three locations downstream from stations 1, 2 and 4. Time and sample position across the creek were not significant factors affecting E. coli concentrations in sediment; location along the creek was a significant factor. Initial E. coli concentrations in top 1 cm (just prior to flow) averaged 4500, 2500, and 500 cell per g of sediment at locations 1 and 2 and 4, respectively. The E. coli concentrations in sediments decreased exponentially with depth by about one order of magnitude per 2 cm. The artificial flow event was created by releasing 80 tons of tap water on a tarp-covered stream bank at 11 m above the station 1 at a rate of 60 L per second in four equal allotments separated by 1, 3, and 1 min break intervals. The initial flow in the creek was insignificant. Both rising and falling limbs of the hydrographs became less steep as the water pulse moved along the creek; the break intervals were not discernible in hydrographs at stations 2, 3 and 4. Bacteria breakthrough concentrations at all stations were typical for the advective-dispersive transport concept, and had the long tails indicative of low rates of settling caused by re-entrainment of the sediment and E. coli associated with it. The tail concentrations were far above the regulatory threshold for E. coli concentrations indicating microbiological impairment. The E. coli mass balance computations showed that net E. coli resuspension rates (resuspension minus settling) upstream from station 1, and at the 140 m reaches between stations 1 and 2, and 2 and 3, were 15000, 6000, and 1500 cell per sq. m per sec, respectively. These rates could be crudely estimated as the total amount of bacteria in the top 1 cm sediment layer released within an hour. The bacteria concentrations in sediment samples from reaches approximately 2 hours after flow event initiation were smaller than before the event; this decrease compared favorable with the abovementioned resuspension rates. Although hydrographs at stations 2, 3 and 4 were quite similar, the net E. coli resuspension rate at the 350-m reach between stations 3 and 4, was -1500 cell per sq. m per sec, while the E. coli concentrations in sediment below station 4 did not change significantly. Sediment texture varied along the creek. Sediment was predominantly sandy upstream from station 1, and between stations 1 and 2, while the amount of silt and clay gradually increased from station 2 to 4. Sediment bacteria concentrations were smaller in those parts of the creek bottom having a finer texture, and the net E. coli resuspension rate decreased. The differences in resuspension could be explained by the stronger association of bacteria with silty and clay sediment particles as compared with sandy particles. We have observed this previously with soils. Relatively small bottom roughness causes smaller bed shear stress could be another reason for the texture-dependent E. coli resuspension. Overall, bottom sediments, as E. coli reservoirs, released bacteria in substantial numbers during the artificial high-flow event. Bacteria resuspension and settling rates were affected by the sediment texture. The observations in this work indicate that artificial high flow events can provide useful information on these rates in small creeks, and that the calibration of the convective dispersive transport model of suspended E. coli is apparently the technique of choice for obtaining this information.
Turbulent flow and heat transfer of Water/Al2O3 nanofluid inside a rectangular ribbed channel
NASA Astrophysics Data System (ADS)
Parsaiemehr, Mohammad; Pourfattah, Farzad; Akbari, Omid Ali; Toghraie, Davood; Sheikhzadeh, Ghanbarali
2018-02-01
In present study, the turbulent flow and heat transfer of Water/Al2O3 nanofluid inside a rectangular channel have been numerically simulated. The main purpose of present study is investigating the effect of attack angle of inclined rectangular rib, Reynolds number and volume fraction of nanoparticles on heat transfer enhancement. For this reason, the turbulent flow of nanofluid has been simulated at Reynolds numbers ranging from 15000 to 30000 and volume fractions of nanoparticles from 0 to 4%. The changes attack angle of ribs have been investigated ranging from 0 to 180°. The results show that, the changes of attack angle of ribs, due to the changes of flow pattern and created vortexes inside the channel, have significant effect on fluid mixing. Also, the maximum rate of heat transfer enhancement accomplishes in attack angle of 60°. In Reynolds numbers of 15000, 20000 and 30000 and attack angle of 60°, comparing to the attack angle of 0°, the amount of Nusselt number enhances to 2.37, 1.96 and 2 times, respectively. Also, it can be concluded that, in high Reynolds numbers, by using ribs and nanofluid, the performance evaluation criterion improves.
NASA Astrophysics Data System (ADS)
Hua, Junye; Duan, Yuanyuan; Li, Gui; Xu, Qiong; Li, Dong; Wu, Wei; Zhao, Xiaobao; Qiu, Delai
2018-02-01
The experimental studies on heat transfer and flow resistance characteristics of ellipse-shape micro pin fin have been conducted which is drafted with hydrophobic material, holding the various contact angles fulfilled by adjusting the amount of Nano particle. The results show that with the increases of contact angle(83°,99.5°, 119.5°and 151.5°), the bottom wall temperature rises under the same flow rate. Under a certain heating condition with heating power as 100 W, the average convective heat transfer coefficient decreases with the increase of contact angle with the same Re. The value of Nu for ellipse-shape micro pin fin increases with a higher Re, with the maximum value under experimental condition of Nu as 25. Besides, the friction coefficient of micro pin fin experimental section drafted hydrophobicity treatment significantly decreases, compared with the smooth micro pin fin experimental section (θ = 83°). While the higher contact angle has obvious positive influences on friction coefficient under the same Re. Generally, the flow resistance performance of ellipse-shape micro pin fin drafted with hydrophobic material is better than that without any treatment.
Lee, Pil Hyong; Han, Sang Seok; Hwang, Sang Soon
2008-01-01
Modeling and simulation for heat and mass transport in micro channel are being used extensively in researches and industrial applications to gain better understanding of the fundamental processes and to optimize fuel cell designs before building a prototype for engineering application. In this study, we used a single-phase, fully three dimensional simulation model for PEMFC that can deal with both anode and cathode flow field for examining the micro flow channel with electrochemical reaction. The results show that hydrogen and oxygen were solely supplied to the membrane by diffusion mechanism rather than convection transport, and the higher pressure drop at cathode side is thought to be caused by higher flow rate of oxygen at cathode. And it is found that the amount of water in cathode channel was determined by water formation due to electrochemical reaction plus electro-osmotic mass flux directing toward the cathode side. And it is very important to model the back diffusion and electro-osmotic mass flux accurately since the two flux was closely correlated each other and greatly influenced for determination of ionic conductivity of the membrane which directly affects the performance of fuel cell. PMID:27879774
Portable device and method for determining permeability characteristics of earth formations
Shuck, Lowell Z.
1977-01-01
The invention is directed to a device which is used for determining permeability characteristics of earth formations at the surface thereof. The determination of the maximum permeability direction and the magnitude of permeability are achieved by employing a device comprising a housing having a central fluid-injection port surrounded by a plurality of spaced-apart fluid flow and pressure monitoring ports radially extending from the central injection port. With the housing resting on the earth formation in a relatively fluid-tight manner as provided by an elastomeric pad disposed therebetween, fluid is injected through the central port into the earth formation and into registry with the fluid-monitoring ports disposed about the injection port. The fluid-monitoring ports are selectively opened and the flow of the fluid through the various fluid ports is measured so as to provide a measurement of flow rates and pressure distribution about the center hole which is indicative on the earth formation permeability direction and magnitude. For example, the azimuthal direction of the fluid-monitoring ports in the direction through which the greatest amount of injected fluid flows as determined by the lowest pressure distribution corresponds to the direction of maximum permeability in the earth formation.
NASA Astrophysics Data System (ADS)
Gholizadeh, Mohammad; Ghazikhani, Mohsen; Khazaee, Iman
2017-01-01
Humidity and humidification in a proton exchange membrane fuel cells (PEM) can significantly affect the performance of these energy generating devices. Since protons (H+) needs to be accompanied by water molecules to pass from the anode side to the cathode side, the PEM fuel cell membrane should be sufficiently wet. Low or high amount of water in the membrane can interrupt the flow of protons and thus reduce the efficiency of the fuel cell. In this context, several experimental studies and modeling have been carried out on PEM fuel cell and interesting results have been achieved. In this paper, the humidity and flow rate of gas in the anode and cathode are modified to examine its effect on fuel cell performance. The results show that the effect of humidity changing in the anode side is greater than that of the cathode so that at zero humidity of anode and 70 % humidity of the cathode, a maximum current flow of 0.512 A/cm2 for 0.12 V was obtained. However, at 70 % anode humidity and zero cathode humidity, a maximum flow of 0.86 A/cm2 for 0.13 V was obtained.
Nanofiber electrode and method of forming same
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pintauro, Peter N.; Zhang, Wenjing
In one aspect, a method of forming an electrode for an electrochemical device is disclosed. In one embodiment, the method includes the steps of mixing at least a first amount of a catalyst and a second amount of an ionomer or uncharged polymer to form a solution and delivering the solution into a metallic needle having a needle tip. The method further includes the steps of applying a voltage between the needle tip and a collector substrate positioned at a distance from the needle tip, and extruding the solution from the needle tip at a flow rate such as tomore » generate electrospun fibers and deposit the generated fibers on the collector substrate to form a mat with a porous network of fibers. Each fiber in the porous network of the mat has distributed particles of the catalyst. The method also includes the step of pressing the mat onto a membrane.« less
Fluxes of 13 selected pharmaceuticals in the water cycle of Stockholm, Sweden.
Wahlberg, C; Björlenius, B; Paxéus, N
2011-01-01
Mass flows of 13 pharmaceutical active ingredients (APIS) found in drinking water were studied in the water cycle of Stockholm. Data were collected by analyzing samples of surface water, raw water and drinking water as well as influents, effluents and sludges from waste water treatment plants (WWTPs) in Stockholm area. A mass balance was performed, based on sold amounts of pharmaceuticals and the measured concentrations in water and sludge. The selected APls were all present in WWTP effluents and the removal rates for many of them were poor. Mass balance calculations showed that the three studied WWTPs in Stockholm release considerable amounts of the selected APIs into the Baltic Sea while the portions ending up in WWTP sludge were significantly lower. The levels of APIs found in drinking water are low at present, but may increase in the future unless the releases from WWTPs in the catchment of Lake Mälären are mitigated.
A Computational Study to Investigate the Effect of Altitude on Deteriorated Engine Performance
NASA Astrophysics Data System (ADS)
Koh, W. C.; Mazlan, N. M.; Rajendran, P.; Ismail, M. A.
2018-05-01
This study presents an investigation on the effect of operational altitudes on the performance of the deteriorated engine. A two-spool high bypass ratio turbofan engine is used as the test subject for this study. The engine is modelled in Gas Turbine Simulation Program (GSP) based on an existing engine model from literature. Real flight data were used for the validation. Deterioration rate of 0.1% per day is applied for all turbofan components engine. The simulation is performed by varying the altitude from sea level until 9000m. Results obtained show reduction in air mass flow rate and engine thrust as altitude increases. The reduction in air mass flow rate is due to the lower air density at higher altitude hence reduces amount of engine thrust. At 1000m to 4000m, thrust specific fuel consumption (TSFC) of the engine is improved compared to sea level. However depleted in TSFC is shown when the aircraft flies at altitude higher than 4000m. At this altitude, the effect of air density is dominant. As a result, the engine is required to burn more fuel to provide a higher thrust to sustain the aircraft speed. More fuel is consumed hence depletion in TSFC is obtained.
Adsorption kinetic and desorption studies of Cd2+ on Multi-Carboxylic-Functionalized Silica Gel
NASA Astrophysics Data System (ADS)
Li, Min; Wei, Jian; Meng, Xiaojing; Wu, Zhuqiang; Liang, Xiuke
2018-01-01
In the present study, the adsorption behavior of cadmium (II) ion from aqueous solution onto multi-carboxylic-functionalized silica gel (SG-MCF) has been investigated in detail by means of batch and column experiments. Batch experiments were performed to evaluate the effects of contact time on adsorption capacity of cadmium (II) ion. The kinetic data were analyzed on the basis of the pseudo-first-order kinetic and the pseudo-second-order kinetic models and consequently, the pseudo-second-order kinetic can better describe the adsorption process than the pseudo-first-order kinetic model. And the adsorption mechanism of the process was studied by intra-particle and film diffusion, it was found out that the adsorption rate was governed primarily by film diffusion to the adsorption onto the SG-MCF. In addition, column experiments were conducted to assess the effects initial inlet concentration and the flow rate on breakthrough time and adsorption capacity ascertaining the practical applicability of the adsorbent. The results suggest that the total amount of adsorbed cadmium (II) ion increased with declined flow rate and increased the inlet concentration. The adsorption-desorption experiment confirmed that adsorption capacity of cadmium (II) ion didn’t present an obvious decrease after five cycles.
Adsorption kinetic and desorption studies of Cu2+ on Multi-Carboxylic-Functionalized Silica Gel
NASA Astrophysics Data System (ADS)
Li, Min; Meng, Xiaojing; Liu, Yushuang; Hu, Xinju; Liang, Xiuke
2018-01-01
In the present study, the adsorption behavior of copper (II) ion from aqueous solution onto multi-carboxylic-functionalized silica gel (SG-MCF) has been investigated in detail by means of batch and column experiments. Batch experiments were performed to evaluate the effects of contact time on adsorption capacity of copper (II) ion. The kinetic data were analyzed on the basis of the pseudo-first-order kinetic and the pseudo-second-order kinetic models and consequently, the pseudo-second-order kinetic can better describe the adsorption process than the pseudo-first-order kinetic model. And the adsorption mechanism of the process was studied by intra-particle and film diffusion, it was found out that the adsorption rate was governed primarily by film diffusion to the adsorption onto the SG-MCF. In addition, column experiments were conducted to assess the effects initial inlet concentration and the flow rate on breakthrough time and adsorption capacity ascertaining the practical applicability of the adsorbent. The results suggest that the total amount of adsorbed copper (II) ion increased with declined flow rate and increased the inlet concentration. The adsorption-desorption experiment confirmed that adsorption capacity of copper (II) ion didn’t present an obvious decrease after five cycles.
NASA Astrophysics Data System (ADS)
Cui, Y.
2015-12-01
In order to study surface water and groundwater exchange and renewal capacity of groundwater system of Qaidam Basin, inland northwest China, TOUGH2 (Transport of Unsaturated Groundwater and Heat 2) simulation software was used to establish a two-dimensional variable saturated numerical model of a typical cross-section from the Nuomuhong river to the Amunike mountain. According to previous results, evaporation is a function of soil saturation given as an upper boundary to characterize water transport near surface through iterative calculation. Parameters were calibrated with 52 groundwater observation data by trial-and-error method. Particle tracking and isotopic dating results were combined to simulate groundwater age and calibrate models. The results showed that the typical profile of Qaidam basin can be divided into three lumped groundwater flow systems: (1) The circulation depth (CD) of local groundwater flow system is about 200m, where discharge in this lumped system accounts for 74.4% of the total amount of discharge (TAD), of which spring overflow constitutes large fraction. Groundwater age is generally less than 500 years and renewal rate is 1.13% a-1; (2) The CD of middle flow system can reach 800m, where it takes up 18.5% of TAD, evaporation and river overflows is the main outlet of discharge. Groundwater age is generally less than 10ka and renewal rate is 0.094% a-1; (3) The CD of regional flow system is from 1000 to 1500m. It accounts for 7.1% of TAD, of which evaporation is the largest component. Groundwater age is from 10ka to 50ka and renewal rate of which is 0.0074% a-1. Sulingguole river is the discharge area of regional groundwater system, the age of which is greater than 30ka. The method used here can obtain the renewal capacity of groundwater system and better reflect regional circulation characteristics, which have certain significance for the urgent study of regional groundwater circulation and flow systems in areas with limited available data.
NASA Astrophysics Data System (ADS)
Farzad, Reza; Puttinger, Stefan; Pirker, Stefan; Schneiderbauer, Simon
Liquid-liquid systems are widely used in the several industries such as food, pharmaceutical, cosmetic, chemical and petroleum. Drop size distribution (DSD) plays a key role as it strongly affects the overall mass and heat transfer in the liquid-liquid systems. To understand the underlying mechanisms single drop breakup experiments have been done by several researchers in the Taylor-Couette flow; however, most of those studies concentrate on the laminar flow regime and therefore, there is no sufficient amount of data in the case of in turbulent flows. The well-defined pattern of the Taylor-Couette flow enables the possibility to investigate DSD as a function of the local fluid dynamic properties, such as shear rate, which is in contrast to more complex devices such as stirred tank reactors. This paper deals with the experimental investigation of liquid-liquid DSD in Taylor-Couette flow. From high speed camera images we found a simple correlation for the Sauter mean diameter as a function of the local shear employing image processing. It is shown that this correlation holds for different oil-in-water emulsions. Finally, this empirical correlation for the DSD is used as an input data for a CFD simulation to compute the local breakup of individual droplets in a stirred tank reactor.
Active Magnetic Regenerative Liquefier
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barclay, John A.; Oseen-Send, Kathryn; Ferguson, Luke
2016-01-12
This final report for the DOE Project entitled Active Magnetic Regenerative Liquefier (AMRL) funded under Grant DE-FG36-08GO18064 to Heracles Energy Corporation d.b.a. Prometheus Energy (Heracles/Prometheus) describes an active magnetic regenerative refrigerator (AMRR) prototype designed and built during the period from July 2008 through May 2011. The primary goal of this project was to make significant technical advances toward highly efficient liquefaction of hydrogen. Conventional hydrogen liquefiers at any scale have a maximum FOM of ~0.35 due primarily to the intrinsic difficulty of rapid, efficient compression of either hydrogen or helium working gases. Numerical simulation modeling of high performance AMRL designsmore » indicates certain designs have promise to increase thermodynamic efficiency from a FOM of ~0.35 toward ~0.5 to ~0.6. The technical approach was the use of solid magnetic working refrigerants cycled in and out of high magnetic fields to build an efficient active regenerative magnetic refrigeration module providing cooling power for AMRL. A single-stage reciprocating AMRR with a design temperature span from ~290 K to ~120 K was built and tested with dual magnetic regenerators moving in and out of the conductively-cooled superconducting magnet subsystem. The heat transfer fluid (helium) was coupled to the process stream (refrigeration/liquefaction load) via high performance heat exchangers. In order to maximize AMRR efficiency a helium bypass loop with adjustable flow was incorporated in the design because the thermal mass of magnetic refrigerants is higher in low magnetic field than in high magnetic field. Heracles/Prometheus designed experiments to measure AMRR performance under a variety of different operational parameters such as cycle frequency, magnetic field strength, heat transfer fluid flow rate, amount of bypass flow of the heat transfer fluid while measuring work input, temperature span, cooling capability as a function of cold temperature as a function of the amount of bypass flow of the heat transfer fluid. The operational AMRR prototype can be used to answer key questions such as the best recipe for multiple layers of different magnetic refrigerants in one or more integrated regenerators with varying amounts of bypass flow of the heat transfer fluid. Layered regenerators are necessary to span the AMRR range from 290 K to 120K. Our AMRR performance simulation model predicts that ~10-15 % of bypass flow should significantly improve the thermodynamic performance. Initial results obtained with regenerators made of gadolinium spheres were very encouraging; a temperature span of ~ 50 K (between 295K and 245 K) across both regenerators was achieved with zero bypass flow of the heat transfer fluid and with the magnetic field strength of ~4 T.« less
Low Reynolds number numerical solutions of chaotic flow
NASA Technical Reports Server (NTRS)
Pulliam, Thomas H.
1989-01-01
Numerical computations of two-dimensional flow past an airfoil at low Mach number, large angle of attack, and low Reynolds number are reported which show a sequence of flow states leading from single-period vortex shedding to chaos via the period-doubling mechanism. Analysis of the flow in terms of phase diagrams, Poincare sections, and flowfield variables are used to substantiate these results. The critical Reynolds number for the period-doubling bifurcations is shown to be sensitive to mesh refinement and the influence of large amounts of numerical dissipation. In extreme cases, large amounts of added dissipation can delay or completely eliminate the chaotic response. The effect of artificial dissipation at these low Reynolds numbers is to produce a new effective Reynolds number for the computations.
Copiello, Sergio
2016-01-01
The Discounted Cash Flow method is a long since well-known tool to assess the feasibility of investment projects, as the background which shapes a broad range of techniques, from the Cost-Benefit Analysis up to the Life-Cycle Cost Analysis. Its rationale lies in the comparison of deferred values, only once they have been discounted back to the present. The DCF variant proposed here fits into a specific application field. It is well-suited to the evaluations required in order to structure equitable transactions under the umbrella of Public-Private Partnership. •The discount rate relies upon the concept of expected return on equity, instead than on those of weighted average cost of capital, although the latter is the most common reference within the scope of real estate investment valuation.•Given a feasible project, whose Net Present Value is more than satisfactory, we aim to identify the amount of the additional burdens that could be charged to the project, under the condition of keeping the same economically viable.•The DCF variant essentially deals with an optimization problem, which can be solved by means of simple one-shot equations, derived from financial mathematics, or through iterative calculations if additional constraints must be considered.
Aerodynamic and torque characteristics of enclosed Co/counter rotating disks
NASA Astrophysics Data System (ADS)
Daniels, W. A.; Johnson, B. V.; Graber, D. J.
1989-06-01
Experiments were conducted to determine the aerodynamic and torque characteristics of adjacent rotating disks enclosed in a shroud, in order to obtain an extended data base for advanced turbine designs such as the counterrotating turbine. Torque measurements were obtained on both disks in the rotating frame of reference for corotating, counterrotating and one-rotating/one-static disk conditions. The disk models used in the experiments included disks with typical smooth turbine geometry, disks with bolts, disks with bolts and partial bolt covers, and flat disks. A windage diaphragm was installed at mid-cavity for some experiments. The experiments were conducted with various amounts of coolant throughflow injected into the disk cavity from the disk hub or from the disk OD with swirl. The experiments were conducted at disk tangential Reynolds number up to 1.6 x 10 to the 7th with air as the working fluid. The results of this investigation indicated that the static shroud contributes a significant amount to the total friction within the disk system; the torque on counterrotating disks is essentially independent of coolant flow total rate, flow direction, and tangential Reynolds number over the range of conditions tested; and a static windage diaphragm reduces disk friction in counterrotating disk systems.
The role of soil weathering and hydrology in regulating chemical fluxes from catchments (Invited)
NASA Astrophysics Data System (ADS)
Maher, K.; Chamberlain, C. P.
2010-12-01
Catchment-scale chemical fluxes have been linked to a number of different parameters that describe the conditions at the Earth’s surface, including runoff, temperature, rock type, vegetation, and the rate of tectonic uplift. However, many of the relationships relating chemical denudation to surface processes and conditions, while based on established theoretical principles, are largely empirical and derived solely from modern observations. Thus, an enhanced mechanistic basis for linking global solute fluxes to both surface processes and climate may improve our confidence in extrapolating modern solute fluxes to past and future conditions. One approach is to link observations from detailed soil-based studies with catchment-scale properties. For example, a number of recent studies of chemical weathering at the soil-profile scale have reinforced the importance of hydrologic processes in controlling chemical weathering rates. An analysis of data from granitic soils shows that weathering rates decrease with increasing fluid residence times and decreasing flow rates—over moderate fluid residence times, from 5 days to 10 years, transport-controlled weathering explains the orders of magnitude variation in weathering rates to a better extent than soil age. However, the importance of transport-controlled weathering is difficult to discern at the catchment scale because of the range of flow rates and fluid residence times captured by a single discharge or solute flux measurement. To assess the importance of transport-controlled weathering on catchment scale chemical fluxes, we present a model that links the chemical flux to the extent of reaction between the soil waters and the solids, or the fluid residence time. Different approaches for describing the distribution of fluid residence times within a catchment are then compared with the observed Si fluxes for a limited number of catchments. This model predicts high solute fluxes in regions with high run-off, relief, and long flow paths suggesting that the particular hydrologic setting of a landscape will be the underlying control on the chemical fluxes. As such, we reinterpret the large chemical fluxes that are observed in active mountain belts, like the Himalaya, to be primarily controlled by the long reactive flow paths created by the steep terrain coupled with high amounts of precipitation.
Nordstrom, D. Kirk
2011-01-01
Mobility of potential or actual contaminants from mining and mineral processing activities depends on (1) occurrence: is the mineral source of the contaminant actually present? (2) abundance: is the mineral present in sufficient quantity to make a difference? (3) reactivity: what are the energetics, rates, and mechanisms of sorption and mineral dissolution and precipitation relative to the flow rate of the water? and (4) hydrology: what are the main flow paths for contaminated water? Estimates of relative proportions of minerals dissolved and precipitated can be made with mass-balance calculations if minerals and water compositions along a flow path are known. Combined with discharge, these mass-balance estimates quantify the actual weathering rate of pyrite mineralization in the environment and compare reasonably well with laboratory rates of pyrite oxidation except when large quantities of soluble salts and evaporated mine waters have accumulated underground. Quantitative mineralogy with trace-element compositions can substantially improve the identification of source minerals for specific trace elements through mass balances. Post-dissolution sorption and precipitation (attenuation) reactions depend on the chemical behavior of each element, solution composition and pH, aqueous speciation, temperature, and contact-time with mineral surfaces. For example, little metal attenuation occurs in waters of low pH (2, and redox-sensitive oxyanions (As, Sb, Se, Mo, Cr, V). Once dissolved, metal and metalloid concentrations are strongly affected by redox conditions and pH. Iron is the most reactive because it is rapidly oxidized by bacteria and archaea and Fe(III) hydrolyzes and precipitates at low pH (1–3) which is related directly to its first hydrolysis constant, pK1 = 2.2. Several insoluble sulfate minerals precipitate at low pH including anglesite, barite, jarosite, alunite and basaluminite. Aluminum hydrolyzes near pH 5 (pK1 = 5.0) and provides buffering and removal of Al by mineral precipitation from pH 4–5.5. Dissolved sulfate behaves conservatively because the amount removed from solution by precipitation is usually too small relative to the high concentrations in the water column and relative to the flow rate of the water.
Stock flow diagram analysis on solid waste management in Malaysia
NASA Astrophysics Data System (ADS)
Zulkipli, Faridah; Nopiah, Zulkifli Mohd; Basri, Noor Ezlin Ahmad; Kie, Cheng Jack
2016-10-01
The effectiveness on solid waste management is a major importance to societies. Numerous generation of solid waste from our daily activities has risked for our communities. These due to rapid population grow and advance in economic development. Moreover, the complexity of solid waste management is inherently involved large scale, diverse and element of uncertainties that must assist stakeholders with deviating objectives. In this paper, we proposed a system dynamics simulation by developing a stock flow diagram to illustrate the solid waste generation process and waste recycle process. The analysis highlights the impact on increasing the number of population toward the amount of solid waste generated and the amount of recycled waste. The results show an increment in the number of population as well as the amount of recycled waste will decrease the amount of waste generated. It is positively represent the achievement of government aim to minimize the amount of waste to be disposed by year 2020.
OVERVIEW OF EPA'S WET-WEATHER FLOW RESEARCH PROGRAM
Surface waters receive three types of urban wet-weather flow discharges: combined-sewer overflow (CSO), stormwater, and sanitary-sewer overflow (SSO); all are principally untreated discharges that occur during storm-flow events. WWFs have proven to generate a substantial amount o...
An Optical Flow-Based Full Reference Video Quality Assessment Algorithm.
K, Manasa; Channappayya, Sumohana S
2016-06-01
We present a simple yet effective optical flow-based full-reference video quality assessment (FR-VQA) algorithm for assessing the perceptual quality of natural videos. Our algorithm is based on the premise that local optical flow statistics are affected by distortions and the deviation from pristine flow statistics is proportional to the amount of distortion. We characterize the local flow statistics using the mean, the standard deviation, the coefficient of variation (CV), and the minimum eigenvalue ( λ min ) of the local flow patches. Temporal distortion is estimated as the change in the CV of the distorted flow with respect to the reference flow, and the correlation between λ min of the reference and of the distorted patches. We rely on the robust multi-scale structural similarity index for spatial quality estimation. The computed temporal and spatial distortions, thus, are then pooled using a perceptually motivated heuristic to generate a spatio-temporal quality score. The proposed method is shown to be competitive with the state-of-the-art when evaluated on the LIVE SD database, the EPFL Polimi SD database, and the LIVE Mobile HD database. The distortions considered in these databases include those due to compression, packet-loss, wireless channel errors, and rate-adaptation. Our algorithm is flexible enough to allow for any robust FR spatial distortion metric for spatial distortion estimation. In addition, the proposed method is not only parameter-free but also independent of the choice of the optical flow algorithm. Finally, we show that the replacement of the optical flow vectors in our proposed method with the much coarser block motion vectors also results in an acceptable FR-VQA algorithm. Our algorithm is called the flow similarity index.
Development of a passive phase separator for space and earth applications
Wu, Xiongjun; Loraine, Greg; Hsiao, Chao-Tsung; Chahine, Georges L.
2018-01-01
The limited amount of liquids and gases that can be carried to space makes it imperative to recycle and reuse these fluids for extended human operations. During recycling processes gas and liquid phases are often intermixed. In the absence of gravity, separating gases from liquids is challenging due to the absence of buoyancy. This paper describes development of a passive phase separator that is capable of efficiently and reliably separating gas–liquid mixtures of both high and low void fractions in a wide range of flow rates that is applicable to for both space and earth applications. PMID:29628785
Impingement of Water Droplets on NACA 65A004 Airfoil at 8 deg Angle of Attack
NASA Technical Reports Server (NTRS)
Brun, R. J.; Gallagher, H. M.; Vogt, D. E.
1954-01-01
The trajectories of droplets in the air flowing past an NACA 65AO04 airfoil at an angle of attack of 8 deg were determined.. The amount of water in droplet form impinging on the airfoil, the area of droplet impingement, and the rate of droplet impingement per unit area on the airfoil surface were calculated from the trajectories and presented to cover a large range of flight and atmospheric conditions. These impingement characteristics are compared briefly with those previously reported for the same airfoil at an angle of attack of 4 deg.
Devitrification and shrinkage behavior of silica fibers
NASA Technical Reports Server (NTRS)
Zaplatynsky, I.
1972-01-01
Devitrification and shrinkage of three batches of silica fibers were investigated in the temperature range of 1200 to 1350 C. Fibers with high water and impurity content devitrified rapidly to cristobalite and quartz and exhibited rapid, but the least amount of, shrinkage. A batch with low water and impurity content devitrified more slowly to cristobalite only and underwent severe shrinkage by the mechanism of viscous flow. A third batch of intermediate purity level and low water content devitrified at a moderate rate mainly to cristobalite but shrunk very rapidly. Completely devitrified silica fibers did not exhibit any further shrinkage.
Magnetic Heat Pump Containing Flow Diverters
NASA Technical Reports Server (NTRS)
Howard, Frank S.
1995-01-01
Proposed magnetic heat pump contains flow diverters for suppression of undesired flows. If left unchecked, undesired flows mix substantial amounts of partially heated and partially cooled portions of working fluid, effectively causing leakage of heat from heated side to cooled side. By reducing leakage of heat, flow diverters increase energy efficiency of magnetic heat pump, potentially offering efficiency greater than compressor-driven refrigerator.
In vivo study of flow-rate accuracy of the MedStream Programmable Infusion System.
Venugopalan, Ramakrishna; Ginggen, Alec; Bork, Toralf; Anderson, William; Buffen, Elaine
2011-01-01
Flow-rate accuracy and precision are important parameters to optimizing the efficacy of programmable intrathecal (IT) infusion pump delivery systems. Current programmable IT pumps are accurate within ±14.5% of their programmed infusion rate when assessed under ideal environmental conditions and specific flow-rate settings in vitro. We assessed the flow-rate accuracy of a novel programmable pump system across its entire flow-rate range under typical conditions in sheep (in vivo) and nominal conditions in vitro. The flow-rate accuracy of the MedStream Programmable Pump was assessed in both the in vivo and in vitro settings. In vivo flow-rate accuracy was assessed in 16 sheep at various flow-rates (producing 90 flow intervals) more than 90 ± 3 days. Pumps were then explanted, re-sterilized and in vitro flow-rate accuracy was assessed at 37°C and 1013 mBar (80 flow intervals). In vivo (sheep body temperatures 38.1°C-39.8°C), mean ± SD flow-rate error was 9.32% ± 9.27% and mean ± SD leak-rate was 0.028 ± 0.08 mL/day. Following explantation, mean in vitro flow-rate error and leak-rate were -1.05% ± 2.55% and 0.003 ± 0.004 mL/day (37°C, 1013 mBar), respectively. The MedStream Programmable Pump demonstrated high flow-rate accuracy when tested in vivo and in vitro at normal body temperature and environmental pressure as well as when tested in vivo at variable sheep body temperature. The flow-rate accuracy of the MedStream Programmable Pump across its flow-rate range, compares favorably to the accuracy of current clinically utilized programmable IT infusion pumps reported at specific flow-rate settings and conditions. © 2011 International Neuromodulation Society.
Nitrous oxide production kinetics during nitrate reduction in river sediments.
Laverman, Anniet M; Garnier, Josette A; Mounier, Emmanuelle M; Roose-Amsaleg, Céline L
2010-03-01
A significant amount of nitrogen entering river basins is denitrified in riparian zones. The aim of this study was to evaluate the influence of nitrate and carbon concentrations on the kinetic parameters of nitrate reduction as well as nitrous oxide emissions in river sediments in a tributary of the Marne (the Seine basin, France). In order to determine these rates, we used flow-through reactors (FTRs) and slurry incubations; flow-through reactors allow determination of rates on intact sediment slices under controlled conditions compared to sediment homogenization in the often used slurry technique. Maximum nitrate reduction rates (R(m)) ranged between 3.0 and 7.1microg Ng(-1)h(-1), and affinity constant (K(m)) ranged from 7.4 to 30.7mg N-NO(3)(-)L(-1). These values were higher in slurry incubations with an R(m) of 37.9microg Ng(-1)h(-1) and a K(m) of 104mg N-NO(3)(-)L(-1). Nitrous oxide production rates did not follow Michaelis-Menten kinetics, and we deduced a rate constant with an average of 0.7 and 5.4ng Ng(-1)h(-1) for FTR and slurry experiments respectively. The addition of carbon (as acetate) showed that carbon was not limiting nitrate reduction rates in these sediments. Similar rates were obtained for FTR and slurries with carbon addition, confirming the hypothesis that homogenization increases rates due to release of and increasing access to carbon in slurries. Nitrous oxide production rates in FTR with carbon additions were low and represented less than 0.01% of the nitrate reduction rates and were even negligible in slurries. Maximum nitrate reduction rates revealed seasonality with high potential rates in fall and winter and low rates in late spring and summer. Under optimal conditions (anoxia, non-limiting nitrate and carbon), nitrous oxide emission rates were low, but significant (0.01% of the nitrate reduction rates). Copyright 2009 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Merka, J.; Sibeck, D. G.; Narock, T. W.
2011-12-01
Fast transient plasma flows in the magnetosphere are usually associated with magnetic reconnection and/or rapid changes in the magnetospheric configuration. Using a common methodology to analyze data from the THEMIS satellites we map the statistical occurrence rate of bursty bulk flows (BBFs) in the magnetosphere. Such a task involves obtaining and processing of large amount of data (5 THEMIS satellites provide measurements since spring of 2007), then writing custom code and searching for intervals of interests. The existence of a Virtual Magnetospheric Observatory (VMO) offers, however, a less laborious alternative. We discuss how the VMO made our research faster and easier and also point out the inherent limitations of the VMO use. The VMO's goal is to help researches by creating a single point of uniform discovery, access, and use of magnetospheric data. Available data can be searched based on various criteria as, for example, spatial location, time of observation, measurement type, parameter values, etc. The results can then be saved, downloaded or displayed as, for example, spatial-temporal plots that quickly reveal where and how often was the searched-for phenomenon observed. Our analysis revealed that the BBFs were found more frequently with increasing distance from Earth and the peak occurrence rate of earthward BBFs was at Xgsm = 29 Re and Ygsm = -2 Re. The tailward BBFs were very rarely observed even between Xgsm = -20 and -30 Re but they occurred over a wide range of local times. The positions with highest BBF occurrence rates differ from previous reports that used IRM and ISEE2 data.
Kuriakose, S; Sundaresan, C; Mathai, V; Khosla, E; Gaffoor, F M A
2013-01-01
This study was conducted to identify various factors in the development of rampant type of dental caries in South Kerala children, other than high sucrose intake and poor oral hygiene. This was done by comparing the salivary buffering capacity(BC), flow-rate(FR), resting pH and salivary immunoglobulin-A(s-IgA) levels in children who are caries resistant(CR) and who have rampant dental caries. Two study groups, a rampant caries group(RC) with more than five active caries lesions in the early stages and a CR with no caries lesions were selected based on a specific criteria. Unstimulated whole mixed saliva was collected directly from the floor of the mouth for a period of 10 min and the FR was calculated. Resting pH of saliva was measured using color coded pH paper. BC was measured by calculating the amount of citric acid of pH2.5, required to lower the initial pH of saliva down to 3. s-IgA levels were also estimated by immunoturbidometric method after forming a precipitate of s-IgA with specific anti-IgA antibodies. The salivary BC, FRs, pH and s-IgA levels were significantly lower in the RC group when compared to the CR group. This study showed that salivary BC, flow-rate, resting pH and levels of s-IgA in saliva are risk factors in the development of RC in children.
NASA Astrophysics Data System (ADS)
Reynolds, S.; Klar, J. K.; Kitidis, V. A.; Chapman-Greig, L.; Panton, A.; Thompson, C.; Statham, P. J.; Fones, G. R.
2016-02-01
Shelf seas are globally important in contributing to the biogeochemical cycling of carbon and nutrients. Much of the benthic environment found in shelf seas comprise of relic permeable sands whereby advective pore-water flow processes govern the biogeochemical cycling within these sediments. To further elucidate our understanding of the biogeochemistry of these systems, flow-through reactors were employed during a field campaign as part of the UK led Shelf Sea Biogeochemistry Programme. Three cruises took place in the southern Celtic Sea in 2015 and were timed to sample pre-bloom, post-bloom and late summer conditions. Preliminary data show marked differences with the pre-bloom and late summer flow-through incubations when compared with the post-bloom. Pre-bloom and late summer oxygen consumption rates ranged between 0.18 mmol O2 m-3 d-1 and 0.15 mmol O2 m-3 d-1 respectively. However, post-bloom oxygen consumption rates were almost double at 0.29 mmol O2 m-3 d-1. Differences were also observed in the amount of iron (II) being released with no marked releases from the pre-bloom and late summer but with significant contributions of up to 140 nM during the post-bloom incubation. These initial findings demonstrate the seasonal variability and extent of the biogeochemical cycling of benthic permeable sediments. Additional measurements of inorganic nutrients, dissolved organic carbon and denitrification rates will contribute further to our understanding of sandy sediments in a shelf sea environment and their capacity to act as a carbon and nutrient source or sink.
Advances in the analysis and prediction of turbulent viscoelastic flows
NASA Astrophysics Data System (ADS)
Gatski, T. B.; Thais, L.; Mompean, G.
2014-08-01
It has been well-known for over six decades that the addition of minute amounts of long polymer chains to organic solvents, or water, can lead to significant turbulent drag reduction. This discovery has had many practical applications such as in pipeline fluid transport, oil well operations, vehicle design and submersible vehicle projectiles, and more recently arteriosclerosis treatment. However, it has only been the last twenty-five years that the full utilization of direct numerical simulation of such turbulent viscoelastic flows has been achieved. The unique characteristics of viscoelastic fluid flow are dictated by the nonlinear differential relationship between the flow strain rate field and the extra-stress induced by the additive polymer. A primary motivation for the analysis of these turbulent fluid flows is the understanding of the effect on the dynamic transfer of energy in the turbulent flow due to the presence of the extra-stress field induced by the presence of the viscoelastic polymer chain. Such analyses now utilize direct numerical simulation data of fully developed channel flow for the FENE-P (Finite Extendable Nonlinear Elastic - Peterlin) fluid model. Such multi-scale dynamics suggests an analysis of the transfer of energy between the various component motions that include the turbulent kinetic energy, and the mean polymeric and elastic potential energies. It is shown that the primary effect of the interaction between the turbulent and polymeric fields is to transfer energy from the turbulence to the polymer.
Lithospheric extension near Lake Mead, Nevada - A model for ductile flow in the lower crust
NASA Technical Reports Server (NTRS)
Kruse, Sarah; Mcnutt, Marcia; Phipps-Morgan, Jason; Royden, Leigh
1991-01-01
Small variations in gravity anomalies and topographic elevation observed in areas that have undergone highly variable amounts of upper crustal thinning can be satisfactorily explained by ductile flow of lower crustal material under the proper conditions. The boundary between the unextended Colorado Plateau and a strongly extended domain in the Basin and Range Province in the Lake Mead (Nevada) region is examined. Finite element modeling of Newtonian flow and power law creep shows that flow over the length scale of the eastern Basin and Range (500) km or more) corresponding to upper crustal extension by a factor of 1.4-3 over 10 million years requires effective viscosities less than 10 to the 18th - 10 to the 20th Pa s for ductile channels 10-25 km thick. Modeling suggests that these effective viscosities may be sustained by lower crustal material deforming at laboratory-derived power law creep rates. The longer-scale flow may require elevated crustal temperatures (more than 700 C), depending on the composition and material properties assumed. Under the boundary conditions assumed in this study the linear viscous flow models yield a satisfactory approximation to deformation by power law creep. This work suggests that flow in the lower crust may be a viable mechanism for producing small variations in total crustal thickness between strongly extended and less extended regions, and thereby explaining the relative uniformity in gravity and topography between such regions.
John, C; Langer, K
2014-06-13
Nanoparticles used as drug delivery systems are of growing interest in the pharmaceutical field. Understanding the behaviour and effects of nanosystems in the human body is dependent on comprehensive characterisation of the systems especially with regard to size and size distribution. Asymmetrical flow field-flow fractionation (AF4) is a promising method for this challenge as this technique enables chromatographic separation of particles and solute molecules according to their respective size. Within this study AF4 was used for the characterisation of human serum albumin (HSA) based nanoparticles. In a first part, the most important aspects of method development like the choice of cross flow rate, focusing and the increase of sample concentration via outlet stream splitting on the sample separation were evaluated. Sample fractionation was controlled by inline-coupling of a dynamic light scattering detector (DLS, Zetasizer) and was confirmed by DLS batch mode measurements. In a second part the applicability of field-flow fractionation for characterisation of the HSA particle formation process by a desolvation method was evaluated. A time dependent particle formation was observed which was controlled by the amount of desolvating agent. Furthermore, field-flow fractionation in combination with in-line dynamic light scattering was used to monitor the increase of particle diameter during PEGylation of the resulting HSA nanoparticles. The separation of nanoparticles from dissolved polyethylene glycol (PEG) could successfully be used for determination of the particles' PEGylation degree. Copyright © 2014 Elsevier B.V. All rights reserved.
Ryter, Derek W.; Correll, Jessica S.
2016-01-14
A hypothetical severe drought was simulated by using aquifer recharge flow rates during the drought year of 2011 for a period of 10 years. All other flows including evapotranspiration and groundwater pumping were set at estimated 2011 rates. The hypothetical drought caused a decrease in water in aquifer storage by about 7 percent in Reach I and 7 percent in Reach II. Another analysis of the effects of hypothetical drought estimated the effects of drought on streamflow and lake storage. The hypothetical drought was simulated by decreasing recharge by 75 percent for a selected 10-year period (1994–2004) during the 1980–2011 simulation. In Reach I, the amounts of water stored in Canton Lake and streamflow at the Seiling, Okla., streamflow-gaging station were analyzed. Streamflow at the Seiling station decreased by a mean of 75 percent and was still diminished by 10 percent after 2011. In Reach II, the effect of drought on the streamflow at the Yukon, Okla., streamflow-gaging station was examined. The greatest mean streamflow decrease was approximately 60 percent during the simulated drought, and after 2011, the mean decrease in streamflow was still about 5 percent. Canton Lake storage decreased by as much as 83 percent during the simulated drought and did not recover by 2011.
Guo, Weijie; Li, Zhu; Cheng, Shuiping; Liang, Wei; He, Feng; Wu, Zhenbin
2014-01-01
To examine the performance of a constructed wetland system on stormwater runoff and domestic sewage (SRS) treatment in central east China, two parallel pilot-scale integrated constructed wetland (ICW) systems were operated for one year. Each ICW consisted of a down-flow bed, an up-flow bed and a horizontal subsurface flow bed. The average removal rates of chemical oxygen demand (CODCr), total suspended solids (TSS), ammonia (NH4(+)-N), total nitrogen (TN) and total phosphorus (TP) were 63.6, 91.9, 38.7, 43.0 and 70.0%, respectively, and the corresponding amounts of pollutant retention were approximately 368.3, 284.9, 23.2, 44.6 and 5.9 g m(-2) yr(-1), respectively. High hydraulic loading rate (HLR) of 200 mm/d and low water temperatures (<15 °C) resulted in significant decrease in removals for TP and NH4(+)-N, but had no significant effects on removals of COD and TSS. These results indicated that the operation of this ICW at higher HLR (200 mm/d) might be effective and feasible for TSS and COD removal, but for acceptable removal efficiencies of nitrogen and phosphorus it should be operated at lower HLR (100 mm/d). This kind of ICW could be employed as an effective technique for SRS treatment.
Laboratory experiments from the toy store
NASA Technical Reports Server (NTRS)
Mcclelland, H. T.
1992-01-01
The following is a laboratory experiment designed to further understanding of materials science. This material could be taught to a typical student of materials science or manufacturing at the high school level or above. The objectives of this experiment are as follows: (1) to qualitatively demonstrate the concepts of elasticity, plasticity, and the strain rate and temperature dependence of the mechanical properties of engineering materials; (2) to qualitatively demonstrate the basics of extrusion including material flow, strain rate dependence of defects, lubrication effects, and the making of hollow shapes by extrusion (the two parts may be two separate experiments done at different times when the respective subjects are covered); and (3) to demonstrate the importance of qualitative observations and the amount of information which can be gathered without quantitative measurements.
Light, Helen M.; Darst, Melanie R.; Grubbs, J.W.
1995-01-01
This report describes progress and interim results of the second year of a 4-year study. The purpose of the 4-year study is to describe aquatic habitat types in the Apalachicola River floodplain and quantify the amount of habitat inundated by the river at various stages. Final results will be used to determine possible effects of altered flows on floodplain habitats and their associated fish communities. The study is being conducted by the U.S. Geological Survey in cooperation with the Northwest Florida Water Management District as part of a comprehensive study of water needs throughout two large river basins in Florida, Georgia, and Alabama. By the end of the second year, approxi- mately 80 to 90 percent of field data collection was completed. Water levels at 56 floodplain and main channel locations at study sites were read numerous times during low water and once or twice during high water. Rating curves estimating the relationship between stage at a floodplain site and flow of the Apalachicola River at Chattahoochee are presented for 3 sites in the upper river. Elevation, substrate type, and amount of vegetative structure were described at 27 cross sections representing eight different floodplain tributary types at upper, middle, and lower river study sites. A summary of substrate and structure information from all cross sections is presented. Substrate and structure characteristics of floodplain habitats inundated when river flow was at record low flow, mean annual low flow, and mean flow are described for 3 cross sections in the upper river. Digital coverage of high-altitude infra-red aerial photography was processed for use in a Geographic Information System which will be used to map aquatic habitats in the third year of the study. A summary of the literature on fish utilization of floodplain habitats is described. Eighty-one percent of the species collected in the main channel of the Apalachicola River are known to occur in floodplain habitats of eastern rivers.
When and where does preferential flow matter - from observation to large scale modelling
NASA Astrophysics Data System (ADS)
Weiler, Markus; Leistert, Hannes; Steinbrich, Andreas
2017-04-01
Preferential flow can be of relevance in a wide range of soils and the interaction of different processes and factors are still difficult to assess. As most studies (including our own studies) focusing on the effect of preferential flow are based on relatively high precipitation rates, there is always the question how relevant preferential flow is under natural conditions, considering the site specific precipitation characteristics, the effect of the drying and wetting cycle on the initial soil water condition and shrinkage cracks, the site specific soil properties, soil structure and rock fragments, and the effect of plant roots and soil fauna (e.g. earthworm channels). In order to assess this question, we developed the distributed, process-based model RoGeR (Runoff Generation Research) to include a large number relevant features and processes of preferential flow in soils. The model was developed from a large number of process based research and experiments and includes preferential flow in roots, earthworm channels, along rock fragments and shrinkage cracks. We parameterized the uncalibrated model at a high spatial resolution of 5x5m for the whole state of Baden-Württemberg in Germany using LiDAR data, degree of sealing, landuse, soil properties and geology. As the model is an event based model, we derived typical event based precipitation characteristics based on rainfall duration, mean intensity and amount. Using the site-specific variability of initial soil moisture derived from a water balance model based on the same dataset, we simulated the infiltration and recharge amounts of all event classes derived from the event precipitation characteristics and initial soil moisture conditions. The analysis of the simulation results allowed us to extracts the relevance of preferential flow for infiltration and recharge considering all factors above. We could clearly see a strong effect of the soil properties and land-use, but also, particular for clay rich soils a strong effect of the initial conditions due to the development of soil cracks. Not too surprisingly, the relevance of preferential flow was much lower when considering the whole range of precipitation events as only considering events with a high rainfall intensity. Also, the influence on infiltration and recharge were different. Despite the model can still be improved in particular considering more realistic information about the spatial and temporal variability of preferential flow by soil fauna and plants, the model already shows under what situation we need to be very careful when predicting infiltration and recharge with models considering only longer time steps (daily) or only matrix flow.
Volcanism on differentiated asteroids (Invited)
NASA Astrophysics Data System (ADS)
Wilson, L.
2013-12-01
The Dawn spacecraft's investigation of 4 Vesta, best-preserved of the early-forming differentiated asteroids, prompts a reappraisal of factors controlling igneous activity on such bodies. Analogy with melt transfer in zones of partial melting on Earth implies that silicate melts moved efficiently within asteroid mantles in complex networks of veins and dikes, so that only a few percent of the mantle consisted of melt at any one time. Thus even in cases where large amounts of mantle melting occurred, the melts did not remain in the mantle to form "magma oceans", but instead migrated to shallow depths. The link between magma flow rate and the stresses needed to keep fractures open and allow flow fast enough to avoid excessive cooling implies that only within asteroids with radii more than ~190-250 km would continuous magma flow from mantle to surface be possible. In all smaller asteroids (including Vesta) magma must have accumulated in sills at the base of the lithosphere (the conductively controlled ~10 km thick thermal boundary layer) or in crustal magma reservoirs near its base. Magma would then have erupted intermittently to the surface from these steadily replenished reservoirs. The average rates of eruption to the surface (or shallow intrusion) should balance the magma production rate, but since magma could accumulate and erupt intermittently from these reservoirs, the instantaneous eruption rates could be hundreds to thousands of cubic m/s, comparable to historic basaltic eruption rates on Earth and very much greater than the average mantle melting rate. The absence of asteroid atmospheres makes explosive eruptions likely even if magmas are volatile-poor. On asteroids with radii less than ~100 km, gases and sub-mm pyroclastic melt droplets would have had speeds exceeding the escape speed assuming a few hundred ppm volatiles, and only cm sized or larger clasts would have been retained. On larger bodies almost all pyroclasts will have returned to the surface after passing through optically dense fire fountains. At low eruption rates and high volatile contents many clasts cooled to form spatter or cinder deposits, but at high eruption rates and low volatile contents most clasts landed hot and coalesced into lava ponds to feed lava flows. Lava flow thickness varies with surface slope, acceleration due to gravity, and lava yield strength induced by cooling. Low gravity on asteroids caused flows to be relatively thick which reduced the effects of cooling, and many flows probably attained lengths of tens of km and stopped as a result of cessation of magma supply from the reservoir rather than cooling. On most asteroids larger than 100 km radius experiencing more than ~30% mantle melting, the erupted volcanic deposits will have buried the original chondritic surface layers of the asteroid to such great depths that they were melted, or at least heavily thermally metamorphosed, leaving no present-day meteoritical evidence of their prior existence. Tidal stresses from close encounters between asteroids and proto-planets may have very briefly increased melting and melt migration speeds in asteroid interiors but only gross structural disruption would have greatly have changed volcanic histories.
DOE Office of Scientific and Technical Information (OSTI.GOV)
HELTON,JON CRAIG; BEAN,J.E.; ECONOMY,K.
2000-05-19
Uncertainty and sensitivity analysis results obtained in the 1996 performance assessment for the Waste Isolation Pilot Plant are presented for two-phase flow the vicinity of the repository under undisturbed conditions. Techniques based on Latin hypercube sampling, examination of scatterplots, stepwise regression analysis, partial correlation analysis and rank transformation are used to investigate brine inflow, gas generation repository pressure, brine saturation and brine and gas outflow. Of the variables under study, repository pressure is potentially the most important due to its influence on spallings and direct brine releases, with the uncertainty in its value being dominated by the extent to whichmore » the microbial degradation of cellulose takes place, the rate at which the corrosion of steel takes place, and the amount of brine that drains from the surrounding disturbed rock zone into the repository.« less
Control of airborne infectious diseases in ventilated spaces
Nielsen, Peter V.
2009-01-01
We protect ourselves from airborne cross-infection in the indoor environment by supplying fresh air to a room by natural or mechanical ventilation. The air is distributed in the room according to different principles: mixing ventilation, displacement ventilation, etc. A large amount of air is supplied to the room to ensure a dilution of airborne infection. Analyses of the flow in the room show that there are a number of parameters that play an important role in minimizing airborne cross-infection. The air flow rate to the room must be high, and the air distribution pattern can be designed to have high ventilation effectiveness. Furthermore, personalized ventilation may reduce the risk of cross-infection, and in some cases, it can also reduce the source of infection. Personalized ventilation can especially be used in hospital wards, aircraft cabins and, in general, where people are in fixed positions. PMID:19740921
A new device for dynamic sampling of radon in air
NASA Astrophysics Data System (ADS)
Lozano, J. C.; Escobar, V. Gómez; Tomé, F. Vera
2000-08-01
A new system is proposed for the active sampling of radon in air, based on the well-known property of activated charcoal to retain radon. Two identical carbon-activated cartridges arranged in series remove the radon from the air being sampled. The air passes first through a desiccant cell and then the carbon cartridges for short sampling times using a low-flow pump. The alpha activity for each cartridge is determined by a liquid scintillation counting system. The cartridge is placed in a holder into a vial that also contains the appropriate amount of scintillation cocktail, in a way that avoids direct contact between cocktail and charcoal. Once dynamic equilibrium between the phases has been reached, the vials can be counted. Optimum sampling conditions concerning flow rates and sampling times are determined. Using those conditions, the method was applied to environmental samples, straightforwardly providing good results for very different levels of activity.
Discrepancy between Snowmelt and Soil Infiltration
NASA Astrophysics Data System (ADS)
Fassnacht, S. R.
2017-12-01
A majority of snowmelt enters the soil and is either transmitted through or stored in the soil. Snowmelt has been estimated from the decrease in snow mass of a snow pillow and soil infiltration has been estimated from near surface TDR probes. Here, these data are from a set of Snow Telemetry (SNOTEL) stations across Colorado. While seasonal totals are similar, it is shown that there is a disconnect between the amount of water melted in a day and the increased daily volume of water measured in the near sub-surface. It is surmised that these differences are a function of the data collection methods, the infiltration rate, and possible lateral flow. An examination of daily infiltration volumes at depth shows a further disconnect, as it is likely that lateral flow complicates the measurements to a true three dimensional problem. The data are informative to illustrate the transmission of meltwater into the soil; methods for improvement are explored.
[Home Daily Hemodialysis with NxStage System One: monocentric italian casistic results].
Brunati, Chiara; Cassaro, Franca; Cretti, Laura; Izzo, Michela; Pegoraro, Marisa; Negri, Daniela; Gervasi, Francesca; Colussi, Giacomo
2017-09-28
NxStage System One is a new dialytic technology based on easy setup, simplicity of use and reduced dimensions, which is increasingly in use worldwide for home hemodialysis treatments. The system utilizes a low amount of dialysate, usually 15-30 liters according to anthropometric patients' values. The dialysate is supplied at very low flux, generally about 1/3 of blood flow, in order to obtain an elevated saturation of dialysate for solutes. In these conditions the clearance of urea will be almost equal to dialysate flow rate. In order to achieve an obptimal weekly clearance evaluated by Std Kt/V the dialysis sessions are repeated six times a week. In this way a good control of blood voleme can be reached. In this paper we report our experience of treatment with NxStage System One in 12 patients from May 2011 to Dicember 2016. Copyright by Società Italiana di Nefrologia SIN, Rome, Italy.
Marin, Manuela M.; Bhattacharya, Joydeep
2013-01-01
Being “in flow” or “in the zone” is defined as an extremely focused state of consciousness which occurs during intense engagement in an activity. In general, flow has been linked to peak performances (high achievement) and feelings of intense pleasure and happiness. However, empirical research on flow in music performance is scarce, although it may offer novel insights into the question of why musicians engage in musical activities for extensive periods of time. Here, we focused on individual differences in a group of 76 piano performance students and assessed their flow experience in piano performance as well as their trait emotional intelligence. Multiple regression analysis revealed that flow was predicted by the amount of daily practice and trait emotional intelligence. Other background variables (gender, age, duration of piano training and age of first piano training) were not predictive. To predict high achievement in piano performance (i.e., winning a prize in a piano competition), a seven-predictor logistic regression model was fitted to the data, and we found that the odds of winning a prize in a piano competition were predicted by the amount of daily practice and the age at which piano training began. Interestingly, a positive relationship between flow and high achievement was not supported. Further, we explored the role of musical emotions and musical styles in the induction of flow by a self-developed questionnaire. Results suggest that besides individual differences among pianists, specific structural and compositional features of musical pieces and related emotional expressions may facilitate flow experiences. Altogether, these findings highlight the role of emotion in the experience of flow during music performance and call for further experiments addressing emotion in relation to the performer and the music alike. PMID:24319434
Goikoetxea, Estibalitz; Murgia, Xabier; Serna-Grande, Pablo; Valls-i-Soler, Adolf; Rey-Santano, Carmen; Rivas, Alejandro; Antón, Raúl; Basterretxea, Francisco J.; Miñambres, Lorena; Méndez, Estíbaliz; Lopez-Arraiza, Alberto; Larrabe-Barrena, Juan Luis; Gomez-Solaetxe, Miguel Angel
2014-01-01
Objective Aerosol delivery holds potential to release surfactant or perfluorocarbon (PFC) to the lungs of neonates with respiratory distress syndrome with minimal airway manipulation. Nevertheless, lung deposition in neonates tends to be very low due to extremely low lung volumes, narrow airways and high respiratory rates. In the present study, the feasibility of enhancing lung deposition by intracorporeal delivery of aerosols was investigated using a physical model of neonatal conducting airways. Methods The main characteristics of the surfactant and PFC aerosols produced by a nebulization system, including the distal air pressure and air flow rate, liquid flow rate and mass median aerodynamic diameter (MMAD), were measured at different driving pressures (4–7 bar). Then, a three-dimensional model of the upper conducting airways of a neonate was manufactured by rapid prototyping and a deposition study was conducted. Results The nebulization system produced relatively large amounts of aerosol ranging between 0.3±0.0 ml/min for surfactant at a driving pressure of 4 bar, and 2.0±0.1 ml/min for distilled water (H2Od) at 6 bar, with MMADs between 2.61±0.1 µm for PFD at 7 bar and 10.18±0.4 µm for FC-75 at 6 bar. The deposition study showed that for surfactant and H2Od aerosols, the highest percentage of the aerosolized mass (∼65%) was collected beyond the third generation of branching in the airway model. The use of this delivery system in combination with continuous positive airway pressure set at 5 cmH2O only increased total airway pressure by 1.59 cmH2O at the highest driving pressure (7 bar). Conclusion This aerosol generating system has the potential to deliver relatively large amounts of surfactant and PFC beyond the third generation of branching in a neonatal airway model with minimal alteration of pre-set respiratory support. PMID:25211475
Thompson, Ryan F.
2002-01-01
A wetland was constructed in the Skunk Creek flood plain near Lyons in southeast South Dakota to mitigate for wetland areas that were filled during construction of a municipal golf course for the city of Sioux Falls. A water-rights permit was obtained to allow the city to pump water from Skunk Creek into the wetland during times when the wetland would be dry. The amount of water seeping through the wetland and recharging the underlying Skunk Creek aquifer was not known. The U.S. Geological Survey, in cooperation with the city of Sioux Falls, conducted a study during 1997-2000 to evaluate recharge to the Skunk Creek aquifer from the constructed wetland. Three methods were used to estimate recharge from the wetland to the aquifer: (1) analysis of the rate of water-level decline during periods of no inflow; (2) flow-net analysis; and (3) analysis of the hydrologic budget. The hydrologic budget also was used to evaluate the efficiency of recharge from the wetland to the aquifer. Recharge rates estimated by analysis of shut-off events ranged from 0.21 to 0.82 foot per day, but these estimates may be influenced by possible errors in volume calculations. Recharge rates determined by flow-net analysis were calculated using selected values of hydraulic conductivity and ranged from 566,000 gallons per day using a hydraulic conductivity of 0.5 foot per day to 1,684,000 gallons per day using a hydraulic conductivity of 1.0 foot per day. Recharge rates from the hydrologic budget varied from 0.74 to 0.85 foot per day, and averaged 0.79 foot per day. The amount of water lost to evapotranspiration at the study wetland is very small compared to the amount of water seeping from the wetland into the aquifer. Based on the hydrologic budget, the average recharge efficiency was estimated as 97.9 percent, which indicates that recharging the Skunk Creek aquifer by pumping water into the study wetland is highly efficient. Because the Skunk Creek aquifer is composed of sand and gravel, the 'recharge mound' is less distinct than might be found in an aquifer composed of finer materials. However, water levels recorded from piezometers in and around the wetland do show a higher water table than periods when the wetland was dry. The largest increases in water level occur between the wetland channel and Skunk Creek. The results of this study demonstrate that artificially recharged wetlands can be useful in recharging underlying aquifers and increasing water levels in these aquifers.
López-Alías, José F; Martinez-Gomis, Jordi; Anglada, Josep M; Peraire, Maria
2006-09-01
The aims of this study were to quantify the metallic ions released by various dental alloys subjected to a continuous flow of saliva and to estimate the nutritional and toxicological implications of such a release. Four pieces of three nickel-based, one noble, one high-noble and two copper-aluminum alloys were cast and then immersed in a continuous flow of artificial saliva for 15 days. To simulate three meals a day, casts were subjected to thrice-daily episodes, lasting 30 min each and consisting of pH decreases and salinity increases. After 15 days, the metallic ions in the artificial saliva were analyzed. Data were expressed as averaged release rate: microg/cm2/day of ion released for each alloy. The highest value of 95% Cl of each ion was adapted to a hypothetical worst scenario of a subject with 100 cm2 of exposed metal surface. The results were compared with the tolerable upper daily intake level of each ion. The copper-aluminum alloys released copper, aluminum, nickel, manganese and iron. The nickel-based alloys essentially released nickel and chromium, while the beryllium-containing alloy released beryllium and significantly more nickel. The noble and high-noble alloys were very resistant to corrosion. The amount of ions released remained far below the upper tolerable intake level, with the exception of nickel, released by beryllium-containing nickel-based alloy, whose levels approach 50% of this threshold. The daily amount of ions released seems to be far below the tolerable upper intake levels for each ion.
NASA Astrophysics Data System (ADS)
Cheng, Y.; Ogden, F. L.; Zhu, J.
2017-12-01
The hydrologic behavior of steep catchments with saprolitic soils in the humid seasonal tropics varies with land use and cover, even when they have identical topographic index and slope distributions, underlying geology and soils textures. Forested catchments can produce more baseflow during the dry season compared to catchments containing substantial amount of pasture, the so-called "sponge effect". During rainfall events, forested catchments can also exhibit lower peak runoff rates and runoff efficiencies compared to pasture catchments. We hypothesize that hydrologic effects of land use arise from differences in preferential flow paths (PFPs) formed by biotic and abiotic factors in the upper one to two meters of soil and that land use effects on hydrological response are described by the relative amounts of forest and pasture within a catchment. Furthermore, we hypothesize that infiltration measurements at different scales allow estimation of PFP-related parameters. These hypotheses are tested by a model that explicitly simulates PFPs using distinct input parameter sets for forest and pasture. Runoff observations from three catchments with pasture, forest, and a mosaic of subsistence agricultural land covers allow model evaluation. Multiple objective criteria indicate that field measurements of infiltration enable PFP-relevant parameter identification and that pasture and forest end member parameter sets describe much of the observed difference. Analysis of water balance components and comparison between average transient water table depth and vertical PFP flow capacity demonstrate that the interplay of lateral and vertical PFPs contribute to the sponge-effect and can explain differences in peak runoff and runoff efficiency.
NASA Technical Reports Server (NTRS)
Chen, Shu-cheng, S.
2009-01-01
In this paper, preliminary studies on two turbine engine applications relevant to the tilt-rotor rotary wing aircraft are performed. The first case-study is the application of variable pitch turbine for the turbine performance improvement when operating at a substantially lower shaft speed. The calculations are made on the 75 percent speed and the 50 percent speed of operations. Our results indicate that with the use of the variable pitch turbines, a nominal (3 percent (probable) to 5 percent (hypothetical)) efficiency improvement at the 75 percent speed, and a notable (6 percent (probable) to 12 percent (hypothetical)) efficiency improvement at the 50 percent speed, without sacrificing the turbine power productions, are achievable if the technical difficulty of turning the turbine vanes and blades can be circumvented. The second casestudy is the contingency turbine power generation for the tilt-rotor aircraft in the One Engine Inoperative (OEI) scenario. For this study, calculations are performed on two promising methods: throttle push and steam injection. By isolating the power turbine and limiting its air mass flow rate to be no more than the air flow intake of the take-off operation, while increasing the turbine inlet total temperature (simulating the throttle push) or increasing the air-steam mixture flow rate (simulating the steam injection condition), our results show that an amount of 30 to 45 percent extra power, to the nominal take-off power, can be generated by either of the two methods. The methods of approach, the results, and discussions of these studies are presented in this paper.
Uptake of uranium from seawater by amidoxime-based polymeric adsorbent marine testing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tsouris, C.; Kim, J.; Oyola, Y.
2013-07-01
Amidoxime-based polymer adsorbents in the form of functionalized fibers were prepared at the Oak Ridge National Laboratory (ORNL) and screened in laboratory experiments, in terms of uranium uptake capacity, using spiked uranium solution and seawater samples. Batch laboratory experiments conducted with 5-gallon seawater tanks provided equilibrium information. Based on results from 5-gallon experiments, the best adsorbent was selected for field-testing of uranium adsorption from seawater. Flow-through column tests have been performed at different marine sites to investigate the uranium uptake rate and equilibrium capacity under diverse biogeochemistry. The maximum amount of uranium uptake from seawater tests at Sequim, WA, wasmore » 3.3 mg U/g adsorbent after eight weeks of contact of the adsorbent with seawater. This amount was three times higher than the maximum adsorption capacity achieved in this study by a leading adsorbent developed by the Japan Atomic Energy Agency (JAEA), which was 1.1 mg U/g adsorbent at equilibrium. The initial uranium uptake rate of the ORNL adsorbent was 2.6 times higher than that of the JAEA adsorbent under similar conditions. A mathematical model derived from the mass balance of uranium was employed to describe the data. (authors)« less
Estimation of mercury amount in the components of spent U-type lamp.
Rhee, Seung-Whee
2017-05-01
Spent U-type lamps are strongly encouraged to be separately managed in Korea, because U-type lamps are categorized as a household waste and thereby could not be managed properly. Determination of mercury amount in the components of U-type lamp, such as plastics, glass tube and phosphor powder from 3 U-type lamp manufacturers (A, B and C), is carried out to estimate the mercury content in spent U-type lamps. Regardless of lamp manufacturers, the portion of mercury in phosphor powder was higher than 90%, but that in plastics and others was less than 1%. At an air flow rate of 1.0 L/min, the range of the initial mercury concentration in vapor phase for U-type lamp was between 849 and 2076 µg/m 3 from 3 companies. The estimated mercury amount in vapor phase of U-type lamp was in the range from 0.206 mg for company A to 0.593 mg for company B. And the portion of mercury in vapor phase in the total amount of mercury was estimated in the range from 3.0% for company A to 6.7% for company B. Hence, it is desirable to get rid of mercury from phosphor powder in order to perform U-type lamps recycling.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Klaus, S.R., E-mail: klaus@geol.uni-erlangen.de; Neubauer, J., E-mail: juergen.neubauer@gzn.uni-erlangen.de; Goetz-Neunhoeffer, F., E-mail: friedlinde.goetz@gzn.uni-erlangen.de
2013-01-15
Much is already known about the hydration of monocalcium aluminate (CA) in calcium aluminate cements (CACs). CA{sub 2} is known to be weakly hydraulic. Therefore, the hydration kinetics of CA{sub 2} were not of as great interest as those of the hydration of CAC. We were able to show that the hydration of CA{sub 2} begins as soon as the hydration rate of CA has reached its maximum and the first precipitation of C{sub 2}AH{sub 8} has started. The hydration of different CA/CA{sub 2} ratios was analyzed by the G-factor quantification. The individual contributions of the phases CA and CA{submore » 2} to the heat flow were calculated based on the amounts dissolved by applying thermodynamic data. The heat flow as calculated from XRD data was then compared with the measured heat flow. It obtained a good consistency between the two. The very pronounced influence of CA{sub 2} during hydration of CAC can be clearly demonstrated.« less
PIV Measurements of Turbulent Pipe Flow with Drag-Reducing Megasupramolecules
NASA Astrophysics Data System (ADS)
Huynh, David; McMullen, Ryan; McKeon, Beverley; Lhota, Redmond; Wei, Ming-Hsin; Kornfield, Julia
2016-11-01
Toms (1948) was the first to observe that dissolving small amounts of high-molecular weight (HMW) polymers into a liquid can drastically reduce turbulent drag. Ever since, studying polymers in turbulence has been of great fundamental interest, as it can potentially provide insight into the self-sustaining mechanisms of wall turbulence. HMW polymers commonly employed for drag-reduction studies are plagued by chain scission due to the high shear rates accompanying turbulent flow at practical Reynolds numbers (Re); this shear degradation reduces the length of the polymer molecules, diminishing their effectiveness for drag-reduction. However, Wei et al. (2015) have recently developed "megasupramolecules" that perform comparably to traditional HMW polymers and circumvent the shear degradation problem by using end-associating polymers that can break and reassociate reversibly. Particle image velocimetry is used in specialized turbulent pipe flow experiments in the range Re 7.5x104-1.2x105 to investigate and compare the drag and turbulence characteristics of the (Newtonian) baseline, traditional HMW polymer solutions, and megrasupramolecules. The support of The Dow Corporation is gratefully acknowledged.
Albertson, Phillip N.; Torak, Lynn J.
2002-01-01
Simulation results indicate that ground-water withdrawal in the lower Apalachicola-Chattahoochee-Flint River basin during times of drought could reduce stream-aquifer flow and cause specific stream reaches to go dry. Of the 37 reaches that were studied, 8 reaches ranked highly sensitive to pumpage, 13 reaches ranked medium, and 16 reaches ranked low. Of the eight reaches that ranked high, seven contain at least one federally protected mussel species. Small tributary streams such as Gum, Jones, Muckalee, Spring, and Cooleewahee Creeks would go dry at lower pumping rates than needed to dry up larger streams. Other streams that were ranked high may go dry depending on the amount of upstream flow entering the reach; this condition is indicated for some reaches on Spring Creek. A dry stream condition is of particular concern to water and wildlife managers because adequate streamflow is essential for mussel survival.
How snowpack heterogeneity affects diurnal streamflow timing
Lundquist, J.D.; Dettinger, M.D.
2005-01-01
Diurnal cycles of streamflow in snow-fed rivers can be used to infer the average time a water parcel spends in transit from the top of the snowpack to a stream gauge in the river channel. This travel time, which is measured as the difference between the hour of peak snowmelt in the afternoon and the hour of maximum discharge each day, ranges from a few hours to almost a full day later. Travel times increase with longer percolation times through deeper snowpacks, and prior studies of small basins have related the timing of a stream's diurnal peak to the amount of snow stored in a basin. However, in many larger basins the time of peak flow is nearly constant during the first half of the melt season, with little or no variation between years. This apparent self-organization at larger scales can be reproduced by employing heterogeneous observations of snow depths and melt rates in a model that couples porous medium flow through an evolving snowpack with free surface flow in a channel. Copyright 2005 by the American Geophysical Union.
Radiation Pressure-Driven Magnetic Disk Winds in Broad Absorption Line Quasi-Stellar Objects
NASA Technical Reports Server (NTRS)
DeKool, Martin; Begelman, Mitchell C.
1995-01-01
We explore a model in which QSO broad absorption lines (BALS) are formed in a radiation pressure-driven wind emerging from a magnetized accretion disk. The magnetic field threading the disk material is dragged by the flow and is compressed by the radiation pressure until it is dynamically important and strong enough to contribute to the confinement of the BAL clouds. We construct a simple self-similar model for such radiatively driven magnetized disk winds, in order to explore their properties. It is found that solutions exist for which the entire magnetized flow is confined to a thin wedge over the surface of the disk. For reasonable values of the mass-loss rate, a typical magnetic field strength such that the magnetic pressure is comparable to the inferred gas pressure in BAL clouds, and a moderate amount of internal soft X-ray absorption, we find that the opening angle of the flow is approximately 0.1 rad, in good agreement with the observed covering factor of the broad absorption line region.
Control volume based hydrocephalus research
NASA Astrophysics Data System (ADS)
Cohen, Benjamin; Voorhees, Abram; Wei, Timothy
2008-11-01
Hydrocephalus is a disease involving excess amounts of cerebral spinal fluid (CSF) in the brain. Recent research has shown correlations to pulsatility of blood flow through the brain. However, the problem to date has presented as too complex for much more than statistical analysis and understanding. This talk will highlight progress on developing a fundamental control volume approach to studying hydrocephalus. The specific goals are to select physiologically control volume(s), develop conservation equations along with the experimental capabilities to accurately quantify terms in those equations. To this end, an in vitro phantom is used as a simplified model of the human brain. The phantom's design consists of a rigid container filled with a compressible gel. The gel has a hollow spherical cavity representing a ventricle and a cylindrical passage representing the aquaducts. A computer controlled piston pump supplies pulsatile volume fluctuations into and out of the flow phantom. MRI is used to measure fluid velocity, and volume change as functions of time. Independent pressure measurements and flow rate measurements are used to calibrate the MRI data. These data are used as a framework for future work with live patients.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Toma, P.R.; Vargas, E.; Kuru, E.
Flow-pattern instabilities have frequently been observed in both conventional gas-lifting and unloading operations of water and oil in low-pressure gas and coalbed reservoirs. This paper identifies the slug-to-annular flow-pattern transition (STA) during upward gas/liquid transportation as a potential cause of flow instability in these operations. It is recommended that the slug-flow pattern be used mainly to minimize the pressure drop and gas compression work associated with gas-lifting large volumes of oil and water. Conversely, the annular flow pattern should be used during the unloading operation to produce gas with relatively small amounts of water and condensate. New and efficient artificialmore » lifting strategies are required to transport the liquid out of the depleted gas or coalbed reservoir level to the surface. This paper presents held data and laboratory measurements supporting the hypothesis that STA significantly contributes to flow instabilities and should therefore be avoided in upward gas/liquid transportation operations. Laboratory high-speed measurements of flow-pressure components under a broad range of gas-injection rates including STA have also been included to illustrate the onset of large STA-related flow-pressure oscillations. The latter body of data provides important insights into gas deliquification mechanisms and identifies potential solutions for improved gas-lifting and unloading procedures. A comparison of laboratory data with existing STA models was performed first. Selected models were then numerically tested in field situations. Effective field strategies for avoiding STA occurrence in marginal and new (offshore) field applications (i.e.. through the use of a slug or annular flow pattern regimen from the bottomhole to wellhead levels) are discussed.« less