Sample records for flow rate qmax

  1. Comparison of flowrates and voided volumes during non-instrumented uroflowmetry and pressure-flow studies in women with stress incontinence.

    PubMed

    Mueller, Elizabeth R; Litman, Heather; Rickey, Leslie R; Sirls, Larry; Norton, Peggy; Wilson, Tracey; Moalli, Pamela; Albo, Michael; Zimmern, Philippe

    2015-08-01

    The Blaivas-Groutz nomogram defines voiding obstruction in women using Qmax from the NIF and the maximum detrusor pressure (Pdetmax ) from the PFS. The aim of this study was to understand the relationship between NIF and PFS maximum flow rates in women with stress incontinence. We analyzed the UDS of 597 women with stress-dominant urinary incontinence. Each subject underwent a NIF and then a PFS. Mixed model was used to test the hypothesis that the relationship between flow rates and voided volume (VV) were similar for NIF and PFS. There were 452 subjects with both NIF and PFS studies that met the inclusion criteria and had max flow rate (Qmax ) for both NIF and PFS. The mean age was 53. Overall, higher VV were observed during PFS compared to NIF and subjects had higher Qmax with NIF compared to PFS. The relationship between Qmax and VV was significantly different between NIF and PFS (P < 0.004). At 200 ml, NIF Qmax was 14% higher than PFS Qmax and this difference increased to 30% at 700 ml. The difference between PFS Qmax and NIF Qmax increases as VV increase. As a result, values from PFS and NIF cannot be used interchangeably as has been suggested in the Blaivas-Groutz nomogram for obstruction in women. © 2014 Wiley Periodicals, Inc.

  2. COMPARISON OF FLOWRATES AND VOIDED VOLUMES DURING NON-INSTRUMENTED UROFLOWMETRY AND PRESSURE-FLOW STUDIES IN WOMEN WITH STRESS INCONTINENCE

    PubMed Central

    Mueller, ER; Litman, H; Rickey, LR; Sirls, L; Norton, P; Wilson, T; Moalli, P; Albo, M; Zimmern, P

    2014-01-01

    Aims The Blaivas-Groutz nomogram defines voiding obstruction in women using Qmax from the NIF and the maximum detrusor pressure (Pdetmax) from the PFS. The aim of this study was to understand the relationship between NIF and PFS maximum flow rates in women with stress incontinence. Methods We analyzed the UDS of 597 women with stress-dominant urinary incontinence. Each subject underwent a NIF and then a PFS. Mixed model was used to test the hypothesis that the relationship between flow rates and voided volume were similar for NIF and PFS. Results There were 452 subjects with both NIF and PFS studies that met the inclusion criteria and had max flow rate (Qmax) for both NIF and PFS. The mean age was 53. Overall, higher voided volumes were observed during PFS compared to NIF and subjects had higher Qmax with NIF compared to PFS. The relationship between Qmax and VV was significantly different between NIF and PFS (p < 0.004). At 200 mL, NIF Qmax was 14% higher than PFS Qmax and this difference increased to 30% at 700mL. Conclusion The difference between PFS Qmax and NIF Qmax increases as voided volumes increase. As a result, values from PFS and NIF cannot be used interchangeably as has been suggested in the Blaivas-Groutz nomogram for obstruction in women. PMID:24797058

  3. Effect of Preoperative Low Maximal Flow Rate on Postoperative Voiding Trials after the Midurethral Sling Procedure in Women with Stress Urinary Incontinence.

    PubMed

    Chae, Ji Y; Bae, Jae H; Lee, Jeong G; Park, Hong S; Moon, Du G; Oh, Mi M

    2017-06-02

    To evaluate the effects of preoperative low maximal flow rate (Qmax) on voiding trials after the midurethral sling (MUS) procedure in women with stress urinary incontinence (SUI). One hundred and sixty-eight women who underwent MUS procedure were enrolled. Preoperative free uroflowmetry was performed and patients were divided by Qmax. Low Qmax was defined as a Qmax under 15 mL/sec with voided volume at least 150 mL. Surgical results, failure of voiding trial, and postoperative uroflowmetry parameters were compared between the groups. Failure of voiding trial was defined by a PVR more than 100 mL on postoperative uroflowmetry. At the discharge day, there were 42 cases showing failure of voiding trial and 33 cases requiring CIC, but only one patient showed failure of voiding trial at 12 months postoperatively. Overall, 48 patients had preoperative low Qmax. Low Qmax group showed lower Qmax in all of postoperative uroflowmetry, but there were no significant differences in the rate of postoperative voiding trial failure or CIC. The low Qmax group was then divided into two groups according to the preoperative detrusor pressure at Qmax over and under 20 cmH 2 O in pressure flow study. Comparing the two groups, no significant differences were observed in the cure rate, voiding trial failure or CIC. Our results suggest that women with preoperative low Qmax experienced no definite unfavorable voiding problem from the MUS procedure compared to those with normal voiding function. MUS procedure may be regarded as a safe and successful procedure in SUI women with low Qmax. © 2017 John Wiley & Sons Australia, Ltd.

  4. Avoid cruising on the uroflowmeter: evaluation of cruising artifact on spinning disc flowmeters in an experimental setup.

    PubMed

    Addla, Sanjai Kumar; Marri, Rajender Reddy; Daayana, Sai Lakshmi; Irwin, Paul

    2010-09-01

    The aim of our study was to access the variability of maximum flow rate (Q(max)), average flow rate (Q(av)) and flow pattern while varying the point of impact of flow on the flowmeter. Water was delivered through a motorised tube holder in a standardised experimental set up. Flow was directed in 4 different directions on the funnel; 1) Periphery, 2) Base, 3) Centre and, 4) in a cruising motion from the periphery of the funnel to the centre and back again. The variation in the Q(max), Q(av) and the flow pattern were studied at 4 different flow rates. The variables recorded when the flow was directed at the centre of the funnel was taken as baseline. There was a significant difference in the Q(max) and Q(av)when the point of impact was at the periphery or in a cruising motion compared to the centre. The difference was more marked with cruising motion with a characteristic flow pattern. The maximum percentage difference in Q(av) was 4.1%, whereas the difference in Q(max) was higher at 16.6% on comparing crusing motion with the values from the centre. We have demonstrated a significant variation in Q(max), Q(av) and flow pattern with change in the point of impact on the flowmeter. Though the changes in Q(av) were statistically significant, the alteration in the recorded Q(max) values was more striking. Our study emphasizes the importance of combining Q(av) and flow pattern along with Q(max) in interpretation of results of uroflowmetry. © 2010 Wiley-Liss, Inc.

  5. Age, gender, and voided volume dependency of peak urinary flow rate and uroflowmetry nomogram in the Indian population

    PubMed Central

    Kumar, Vikash; Dhabalia, Jayesh V.; Nelivigi, Girish G.; Punia, Mahendra S.; Suryavanshi, Manav

    2009-01-01

    Objectives: The objective of this study was measurement of urine flow parameters by a non invasive urodynamic test. Variation of flow rates based on voided volume, age, and gender are described. Different nomograms are available for different populations and racial differences of urethral physiology are described. Currently, there has been no study from the Indian population on uroflow parameters. So the purpose of this study was to establish normal reference ranges of maximum and average flow rates, to see the influence of age, gender, and voided volume on flow rates, and to chart these values in the form of a nomogram. Methods: We evaluated 1,011 uroflowmetry tests in different age groups in a healthy population (healthy relatives of our patients) 16-50 year old males, >50 year old males, 5-15 year old children, and >15 year pre-menopausal and post-menopausal females. The uroflowmetry was done using the gravitimetric method. Flow chart parameters were analyzed and statistical calculations were used for drawing uroflow nomograms. Results: Qmax values in adult males were significantly higher than in the elderly and Qmax values in young females were significantly higher than in young males. Qmax values in males increased with age until 15 years old; followed by a slow decline until reaching 50 years old followed by a rapid decline after 50 years old even after correcting voided volume. Qmax values in females increased with age until they reached age 15 followed by decline in flow rate until a pre-menopausal age followed by no significant decline in post-menopausal females. Qmax values increased with voided volume until 700 cc followed by a plateau and decline. Conclusions: Qmax values more significantly correlated with age and voided volume than Qavg. Nomograms were drawn in centile form to provide normal reference ranges. Qmax values in our population were lower than described in literature. Patients with voided volume up to 50 ml could be evaluated with a nomogram. PMID:19955668

  6. A comparative assessment of irrigation and drainage characteristics for commercially available urethral catheters

    PubMed Central

    Davis, Niall F.; McMahon, Barry P.; Walsh, Michael; McDermott, Thomas E.D.; Thornhill, John A.; Manecksha, Rustom P.

    2017-01-01

    Introduction We aimed to investigate irrigation and drainage characteristics of commercially available urethral catheters and determined which catheter offers the best flow characteristics. Material and methods Twelve different commercially available urethral catheters from three companies (Bard™, Rusch™ and Dover™) were investigated to compare their irrigation and drainage properties. Irrigation port, drainage port and overall cross-sectional areas for a 24Fr 3-way catheter was measured and compared. The maximum (Qmax) and average (Qavg) irrigation and drainage flow rates for each catheter was measured for 20–40 seconds using uroflowmetry. The primary endpoint was to determine which catheter offers optimal irrigation and drainage parameters. Results Overall cross-sectional area, irrigation port cross-sectional area, and drainage port cross-sectional area differed significantly for each 24Fr 3-way catheter assessed (p <0.001). The 24Fr 3-way Rusch Simplastic™ catheter consistently demonstrated the greatest maximal flow rate (Qmax: 5 ±0.3 ml/s) and average flow rate (Qavg: 4.6 ±0.2 ml/s) for irrigation. The 24Fr 3-way Dover™ catheter provided the greatest drainage properties (Qmax: 19.7 ±2 ml/s; Q avg: 15.9 ±5 ml/s). In the setting of continuous bladder irrigation, the 24Fr 3-way Rusch Simplastic™ catheter provided the highest irrigation rates (Qmax: 6.6 ±1.8 ml/s; Q avg: 4.6 ±0.9 ml/s). Conclusions Three-way catheters demonstrate significant differences in their irrigation and drainage characteristics. The type of catheter selected should be based on the appropriate prioritization of efficient bladder irrigation versus efficient bladder drainage. PMID:29410890

  7. The effect of alpha blockers on uroflowmetric parameters in different voiding positions

    PubMed Central

    Koc, Gokhan; Yilmaz, Yuksel; Un, Sitki; Akbay, Kaan; Akdeniz, Firat

    2013-01-01

    Introduction: We assessed the effect of different voiding positions on uroflowmetric parameters and post-void residual (PVR) urine volume in symptomatic benign prostatic hyperplasia (BPH) patients. We also evaluated the effect of alpha blockers on PVR in different voiding positions. Methods: The study was performed with 110 BPH patients over 50 years old. In total, 4 uroflowmetries were performed in all patients: 2 patients in the sitting position and 2 in the standing position. PVR was measured with transabdominal ultrasonography. Also, patients were divided into two groups according to the alpha adrenergic blocker treatment; the effect of this treatment on their uroflowmetric parameters in different positions was evaluated. Results: Maximum flow rate (Qmax) and average flow rate (Qave) were significantly higher in patients in the sitting position, but there were no differences in other uroflowmetric parameters and PVR volume (Qmax: 15.5±5.9 mL/s vs. 13.7±5.2 mL/s, Qave: 11.4±4.6 mL/s vs. 10.7± 3.9 mL/s, respectively; p < 0.05). The Qmax and Qave were significantly higher in sitting position, compared to the standing position, in both alpha adrenergic treatment and non-treated groups; again, there were no differences in other uroflowmetric parameters and PVR volume. Conclusion: Qmax and Qave values were significantly higher in the sitting position. Alpha blockers did not affect any change. PMID:23766834

  8. A mathematical model to optimize the drain phase in gravity-based peritoneal dialysis systems.

    PubMed

    Akonur, Alp; Lo, Ying-Cheng; Cizman, Borut

    2010-01-01

    Use of patient-specific drain-phase parameters has previously been suggested to improve peritoneal dialysis (PD) adequacy. Improving management of the drain period may also help to minimize intraperitoneal volume (IPV). A typical gravity-based drain profile consists of a relatively constant initial fast-flow period, followed by a transition period and a decaying slow-flow period. That profile was modeled using the equation VD(t) = (V(D0) - Q(MAX) x t) xphi + (V(D0) x e(-alphat)) x (1 - phi), where V(D)(t) is the time-dependent dialysate volume; V(D0), the dialysate volume at the start of the drain; Q(MAX), the maximum drain flow rate; alpha, the exponential drain constant; and phi, the unit step function with respect to the flow transition. We simulated the effects of the assumed patient-specific maximum drain flow (Q(MAX)) and transition volume (psi), and the peritoneal volume percentage when transition occurs,for fixed device-specific drain parameters. Average patient transport parameters were assumed during 5-exchange therapy with 10 L of PD solution. Changes in therapy performance strongly depended on the drain parameters. Comparing 400 mL/85% with 200 mL/65% (Q(MAX/psi), drain time (7.5 min vs. 13.5 min) and IPV (2769 mL vs. 2355 mL) increased when the initial drain flow was low and the transition quick. Ultrafiltration and solute clearances remained relatively similar. Such differences were augmented up to a drain time of 22 minutes and an IPV of more than 3 L when Q(MAX) was 100 mL/min. The ability to model individual drain conditions together with water and solute transport may help to prevent patient discomfort with gravity-based PD. However, it is essential to note that practical difficulties such as displaced catheters and obstructed flow paths cause variability in drain characteristics even for the same patient, limiting the clinical applicability of this model.

  9. Urine flow acceleration is superior to Qmax in diagnosing BOO in patients with BPH.

    PubMed

    Wen, Jian-guo; Cui, Lin-gang; Li, Yi-dong; Shang, Xiao-ping; Zhu, Wen; Zhang, Rui-li; Meng, Qing-jun; Zhang, Sheng-jun

    2013-08-01

    We performed a retrospective, case-control study to evaluate whether the urine flow acceleration (UFA, mL/s(2)) is superior to maximum uroflow (Qmax, mL/s) in diagnosing bladder outlet obstruction (BOO) in patients with benign prostatic hyperplasia (BPH). In this study, a total of 50 men with BPH (age: 58±12.5 years) and 50 controls (age: 59±13.0 years) were included. A pressure-flow study was used to determine the presence of BOO according to the recommendations of Incontinence Control Society (ICS). The results showed that the UFA and Qmax in BPH group were much lower than those in the control group [(2.05±0.85) vs. (4.60±1.25) mL/s(2) and (8.50±1.05) vs. (13.00±3.35) mL/s] (P<0.001). According to the criteria (UFA<2.05 mL/s(2), Qmax<10 mL/s), the sensitivity and specificity of UFA vs. Qmax in diagnosing BOO were 88%, 75% vs. 81%, 63%. UFA vs. Omax, when compared with the results of P-Q chart (the kappa values in corresponding analysis), was 0.55 vs. 0.35. The prostate volume, post void residual and detrusor pressure at Qmax between the two groups were 28.6±9.8 vs. 24.2±7.6 mL, 60.4±1.4 vs. 21.3±2.5 mL and 56.6±8.3 vs. 21.7±6.1 cmH2O, respectively (P<0.05). It was concluded that the UFA is a useful urodynamic parameter, and is superior to Qmax in diagnosing BOO in patients with BPH.

  10. Alpha-1 adrenergic antagonists, 5-alpha reductase inhibitors, phosphodiesterase type 5 inhibitors, and phytotherapic compounds in men with lower urinary tract symptoms suggestive of benign prostatic obstruction: A systematic review and meta-analysis of urodynamic studies.

    PubMed

    Fusco, Ferdinando; Creta, Massimiliano; De Nunzio, Cosimo; Gacci, Mauro; Li Marzi, Vincenzo; Finazzi Agrò, Enrico

    2018-03-31

    To perform a systematic review and meta-analysis of studies evaluating the urodynamic outcomes of alpha-1 adrenergic antagonists (ABs), 5-alpha reductase inhibitors (5-ARIs), phosphodiesterase type 5 inhibitors (PDE5is), and phytotherapic compounds in patients with lower urinary tract symptoms related to benign prostatic obstruction (LUTS/BPO). A systematic review of PubMed/Medline, ISI Web of Knowledge, and Scopus databases was performed in June 2017. We included full papers that met the following criteria: original research; English language; human studies; enrolling LUTS/BPO patients; reporting maximum urinary flow (Qmax), and detrusor pressure at maximum urinary flow (PdetQmax). The primary endpoint was variation in bladder outlet obstruction index (BOOI). Secondary endpoints were variations in Qmax and PdetQmax. Twenty-three studies involving 1044 patients were included in the final analysis. Eighteen, three, two, and one study evaluated the urodynamic outcomes of ABs, 5-ARIs, PDE5is, and phytotherapic compounds, respectively. BOOI, PdetQmax, and Qmax improved in a statistically significant manner in patients receiving ABs and in those receiving 5-ARIs. The overall pooled data showed a mean BOOI change of -15.40 (P < 0.00001) and of -10.55 (P = 0,004) for ABs and 5-ARIs, respectively. Mean PdetQmax and Qmax changes were:12.30 cm H 2 O (P < 0.00001) and +2.27 ml/s (P < 0.00001) for ABs and -9.63 cm H 2 O (P = 0.05), and +1.18 mL/s (P = 0.04) for 5-ARIs. PDE5is and phytotherapic compounds had no significant effects on urodynamic parameters. ABs and 5-ARIs efficiently improve BOOI in men with LUTS/BPO. Both treatments are associated with a clinically significant decrease in PdetQmax but only marginal improvements in Qmax. © 2018 Wiley Periodicals, Inc.

  11. Review of invasive urodynamics and progress towards non-invasive measurements in the assessment of bladder outlet obstruction

    PubMed Central

    Griffiths, C. J.; Pickard, R. S.

    2009-01-01

    Objective: This article defines the need for objective measurements to help diagnose the cause of lower urinary tract symptoms (LUTS). It describes the conventional techniques available, mainly invasive, and then summarizes the emerging range of non-invasive measurement techniques. Methods: This is a narrative review derived form the clinical and scientific knowledge of the authors together with consideration of selected literature. Results: Consideration of measured bladder pressure urinary flow rate during voiding in an invasive pressure flow study is considered the gold standard for categorization of bladder outlet obstruction (BOO). The diagnosis is currently made by plotting the detrusor pressure at maximum flow (pdetQmax) and maximum flow rate (Qmax) on the nomogram approved by the International Continence Society. This plot will categorize the void as obstructed, equivocal or unobstructed. The invasive and relatively complex nature of this investigation has led to a number of inventive techniques to categorize BOO either by measuring bladder pressure non-invasively or by providing a proxy measure such as bladder weight. Conclusion: Non-invasive methods of diagnosing BOO show great promise and a few have reached the stage of being commercially available. Further studies are however needed to validate the measurement technique and assess their worth in the assessment of men with LUTS. PMID:19468436

  12. Comparison of cold-knife optical internal urethrotomy and holmium:YAG laser internal urethrotomy in bulbar urethral strictures

    PubMed Central

    Yenice, Mustafa Gurkan; Sam, Emre; Colakoglu, Yunus; Atar, Feyzi Arda; Sahin, Selcuk; Simsek, Abdulmuttalip; Tugcu, Volkan

    2017-01-01

    Introduction To compare the results of cold-knife optical internal urethrotomy (OIU) and Holmium:YAG laser internal urethrotomy (HIU) in primary bulbar urethral strictures. Material and methods A total of 63 patients diagnosed with primary bulbar urethral stricture between August 2014 and September 2015 were assigned to the OIU (n = 29) and HIU (n = 34) groups. The demographic variables, biochemistry panels, and preoperative and postoperative uroflowmetry results including the maximum flow rate (Qmax) and mean flow rate (Qmean) values, retrograde urethrography, and diagnostic flexible urethroscopy findings were recorded prospectively. Demographic features and preoperative values were not statistically different between groups (p >0.05). Mean surgical times were 18.4 ±2.3 min for OIU and 21.9 ±3.8 min for HIU groups, which was statistically significant (p <0.05). There was no significant difference in complication rates in both groups (p = 0.618). Results Postoperative Qmax values were increased in both groups even though postoperative Qmax values were not significantly different between the two groups in the short- and long-term results at 3, 6, and 12 months (p >0.05). There was no recurrence in the first 3 months in either group. The urethral stricture recurrence rate up to month 12 was not statistically significant for the OIU group (n = 6, 20.7%) as compared to the HIU group (n = 11, 32.4%; p = 0.299). At follow-up, the SFR and IFR was 96% and 88% at 3-months, and 82% and 71% at 12-months, respectively (p <0.001). While almost three-quarters of patients were stone and infection free at 12-months, the majority of those with stones recurrence also had recurrence of their UTI. Conclusions HIU is an alternative method to OIU, and it has similar success rates in the treatment of short segment bulbar urethral strictures. PMID:29732217

  13. Steep Gravel Bedload Rating Curves Obtained From Bedload Traps Shift Effective Discharge to Flows Much Higher Than "Bankfull"

    NASA Astrophysics Data System (ADS)

    Bunte, K.; Swingle, K. W.; Abt, S. R.; Cenderelli, D.

    2012-12-01

    Effective discharge (Qeff) is defined as the flow at which the product of flow frequency and bedload transport rates obtains its maximum. Qeff is often reported to correspond with bankfull flow (Qbf), where Qeff approximates the 1.5 year recurrence interval flow (Q1.5). Because it transports the majority of all bedload, Qeff is considered a design flow for stream restoration and flow management. This study investigates the relationship between Qeff and Q1.5 for gravel bedload in high elevation Rocky Mountain streams. Both the flow frequency distribution (FQ = a × Qbin-b) where Qbin is the flow class, and the bedload transport rating curve (QB = c × Qd) can be described by power functions. The product FQ × QB = (a × c × Q(-b + d)) is positive if d + -b >0, and negative if d + -b <0. FQ × QB can only attain a maximum (=Qeff) if either FQ or QB exhibit an inflection point. In snowmelt regimes, low flows prevail for much of the year, while high flows are limited to a few days, and extreme floods are rare. In log-log plotting scale, this distribution causes the longterm flow frequency function FQ to steepen in the vicinity of Q1.5. If the bedload rating curve exponent is small, e.g., = 3 as is typical of Helley-Smith bedload samples, d + -b shifts from >0 to <0, causing FQ × QB to peak, and Qeff to be around Q1.5. For measurements thought to be more representative of actual gravel transport obtained using bedload traps and similar devices, large rating curve exponents d of 6 - 16 are typical. In this case, d + -b remains >0, and FQ × QB reaches its maximum near the largest flow on record (Qeff,BT = Qmax). Expression of FQ by negative exponential functions FQ = k × e(Qbin×-m) smooths the product function FQ × QB that displays its maximum as a gentle hump rather than a sharp peak, but without drastically altering Qeff. However, a smooth function FQ × QB allows Qeff to react to small changes in rating curve exponents d. As d increases from <1 to >10, Qeff increases from Qmin to Qmax. The S-shaped relationship of Qeff vs. d shows that changes in d between about 4 and 8 exert the largest influence on Qeff. Not only FQ, but also QB may change its steepness. QB may flatten during floods as flows overtop banks. Many high elevation Rocky Mountain streams are entrenched due to floodplain buildup (overbank deposition and beaver activity) and downcutting. Preliminary flow modeling suggests that bank overtopping starts when Q1.5 >150%, and flows are fully out-of-bank past 200-250% Q1.5. A flattening of the bedload rating curve shifts Qeff from Qmax to within 150-250% Q1.5. Study results suggest that Qeff likely occurs within 150-250% Q1.5, and the often-quoted similarity of Qeff and Qbf (assuming Qbf = Q1.5) does not hold for the study streams, but is rather an artifact of using a Helley-Smith sampler that produces low rating curve exponents near 3. This finding calls into question the utility of Q1.5 or "bankfull flow" as a morphological design flow in high elevation Rocky Mountain streams.

  14. Comparative Results of Transurethral Incision with Transurethral Resection of The Prostate in Renal Transplant Recipients with Benign Prostate Hyperplasia.

    PubMed

    Sarier, Mehmet; Duman, Ibrahim; Kilic, Suleyman; Yuksel, Yucel; Demir, Meltem; Aslan, Mesut; Yucetin, Levent; Tekin, Sabri; Yavuz, Asuman Havva; Emek, Mestan

    2018-02-18

    The aim of this study is to compare the results of transurethral incision of the prostate (TUIP) and transurethral resection of the prostate (TURP) for the surgical treatment of benign prostate hyperplasia (BPH) in patients with renal transplantation. Between April 2009 and May 2016, BPH patients with renal transplants whose prostate volumes were less than 30 cm3 were treated surgically. Forty-seven patients received TURP and 32 received TUIP. The patients' age, duration of dialysis, duration between transplant and TURP/TUIP, preoperative and postoperative serum creatinine (SCr), International Prostate Symptom Score (IPSS), maximum flow rate (Qmax) and postvoidresidual volume (PVR) were recorded. At 1-,6- and 12-month follow-up, early and long-term complications were assessed. Results were evaluated retrospectively. In both groups, SCr, PVR and IPSS decreased significantly after the operation, while Qmax increased significantly (P < .001). There was no difference between the two groups in terms of increase in Qmax and decrease in IPSS, SCr and PVR (P = .89, P = .27, P = .08, and P = .27). Among postoperative complications, urinary tract infection (UTIs) and retrograde ejaculation (RE) rates were higher in the TURP group than the TUIP group (12.7% versus 6.2% and 68.1% versus 25%,respectively), whereas urethral strictures were more prevalent in the TUIP group (12.5% versus 6.3%). For the treatment of BPH in renal transplant patients with a prostate volume less than 30 cm3, bothTUIP and TURP are safe and effective.

  15. Photoselective vaporization with the green light laser vs transurethral resection of the prostate for treating benign prostate hyperplasia: a systematic review and meta-analysis.

    PubMed

    Teng, Jingfei; Zhang, Dongxu; Li, Yao; Yin, Lei; Wang, Kai; Cui, Xingang; Xu, Danfeng

    2013-02-01

    To assess the overall efficacy and safety of photoselective vaporization of the prostate (PVP) vs transurethral resection of the prostate (TURP) for treating patients with lower urinary tract symptoms (LUTS) secondary to benign prostate hyperplasia (BPH). A systematic search of the electronic databases, including MEDLINE, Embase, Web of Science and The Cochrane Library, as well as manual bibliography searches were performed. The pooled estimates of maximum flow rate (Q(max)), postvoid residual (PVR), quality of life (QoL), International Prostate Symptom Score (IPSS), operation duration, blood loss, catheterization time, hospital stay, capsule perforation, transfusion, transurethral resection (TUR) syndrome, urethral stricture and reintervention were calculated. At the 3-month follow-up, there was no significant difference in Q(max), PVR, QoL and IPSS between the TURP and PVP groups. At the 6-month follow-up, the pooled QoL favoured TURP, but there was no significant difference in the other variables between the two groups. PVP was associated with less blood loss, transfusion, capsular perforation, TUR syndrome, shorter catheterization time and hospital stay, but longer operation duration and higher reintervention rate. The efficacy of PVP was similar to that of TURP in relation to Q(max), PVR, QoL and IPSS, and it offered several advantages over TURP. As a promising minimal invasive technique, PVP could be used as an alternative surgical procedure for treating BPH. © 2012 BJU International.

  16. Sediment motion and velocity in a glacier-fed stream

    NASA Astrophysics Data System (ADS)

    Mao, L.; Dell'Agnese, A.; Comiti, F.

    2017-08-01

    Current understanding of coarse sediment transport (e.g. threshold for motion, travel length and virtual velocity) in mountain rivers is still quite limited, and even less is known about glacial streams. However, the hydrological characteristics of these systems (strong daily discharge fluctuations, high water turbidity) pose challenges to the use of tracers to monitor bed sediment dynamics, as tagged clasts are usually located after bedload events when flow stage has receded, e.g. by means of portable antennas in the case of Passive Integrated Transponders (PIT). The use of stationary antennas, still scarcely in use worldwide, to detect PIT-tagged particles has potential advantages in glacier-fed streams. If water discharge is monitored continuously, a stationary antenna provides real time data on the actual discharge at the moment of tracer particles passage. This study focuses on incipient motion and virtual velocity of bed particles measured by a stationary antennas system in a steep mountain channel (Saldur River, drainage area 18.6 km2, Italian Alps) where significant daily discharge fluctuations and bedload transport occur as a result of a nivo-glacial regime. Four stationary antennas were installed 50-m apart in the study reach. A total of 629 PIT-tagged clasts were inserted in the studied reach between 2011 and 2014, ranging in size from 35 mm to 580 mm, with an overall recovery rate of around 44%. Critical discharge for sediment entrainment was obtained by detecting the movement of tracers placed immediately upstream of antennas. Virtual velocity was derived by knowing distances between the antennas and travel time of tracers. Results on initiation of motion show that the relationship between the size of transported tracers and the discharge measured at the time clasts were passing the stationary antenna is very weak. The influence of antecedent flows on incipient motion was thus investigated by dividing the highest discharge recorded between each PIT deployment and the subsequent entrainment by the actual critical discharge at the time of movement (ratio Qmax/Qc). Results show that approximately 50% of tracers moved at Qmax/Qc ≤ 1.2, and that 73% of tracers moved at Qmax/Qc < 1.5. Therefore, about 30% of tracers had to previously experience a discharge substantially greater than the one that actually mobilized them. Also, coarser particles moved at higher Qmax/Qc ratios, suggesting that higher antecedent flows may be needed to destabilize bed clustering. Results on the virtual velocity of the PIT-tagged clasts employed in the field show that the virtual velocity turned out to be highly variable (ranging from 101 to 10- 5 m min- 1) and weakly related to either particle size or flow discharge. However, virtual velocity was well correlated with the highest flow discharge experienced by each tracer normalized by a percentile of the flow duration curve. This evidence further stresses the importance of flow history on sediment entrainment and transport. Finally, the pros and cons of the deployed monitoring technology are discussed.

  17. Evaluating the efficiency of a combination of Pygeum africanum and stinging nettle (Urtica dioica) extracts in treating benign prostatic hyperplasia (BPH): double-blind, randomized, placebo controlled trial.

    PubMed

    Melo, Ezer A; Bertero, Eduardo B; Rios, Luiz A S; Mattos, Demerval

    2002-01-01

    In spite of its historical use, published data about phytotherapic products is characterized by the absence of well conducted studies, leading to conflictive and indefinite results about efficiency and safety of theses drugs. In that sense, we have analyzed the results of a combination of Pygeum africanum and stinging nettle (Urtica dioica) extracts in patients with benign prostatic hyperplasia (BPH), based in a double-blind, randomized, placebo-controlled protocol. We have selected, according to inclusion and exclusion criteria, only patients with >or=50 years, presenting urinary symptoms assessed by the International Prostatic Symptoms Score (IPSS), with minimum score of 12, and Quality of Life (QoL) index of at least 3 points, rectal examination consistent with BPH, and maximum urinary flow rate (Q(max)) between 5 and 15 mL/s. Phytotherapic and placebo groups were formed by 27 and 22 patients, respectively. The major variables analyzed during the study were IPSS variation, Q(max), and side effects. Reduction of >or=30% and >or=50% in IPSS were the parameters used to define a clinically significant response (CSR). We have also analyzed >or=30% and >or=50% Q(max) increases. After six months of treatment we did not observe significant differences in clinical improvement potential between the phytotherapic combination and placebo groups. Percent IPSS drop of 21.6% in the phytotherapic group was similar to 19.7% obtained in the placebo group (p=0.928). Neither we observed any difference (p=0.530) for QoL improvement between phytotherapic (9.26%) and placebo (5.98%) groups. The alterations of Q(max) followed the trend line observed in clinical data, with no significant difference (p=0.463) in Q(max) increasing percent between phytotherapic (17.2%) and placebo (13.3%) groups. The CSR evaluation of clinical and urodynamic data was also similar between the groups. The combination of 25mg Pygeum africanum and 300mg stinging nettle extracts produced clinical and urodynamic effects similar to placebo in a group of HBP patients.

  18. Open-label study evaluating outpatient urethral sphincter injections of onabotulinumtoxinA to treat women with urinary retention due to a primary disorder of sphincter relaxation (Fowler's syndrome).

    PubMed

    Panicker, Jalesh N; Seth, Jai H; Khan, Shahid; Gonzales, Gwen; Haslam, Collette; Kessler, Thomas M; Fowler, Clare J

    2016-05-01

    To assess the efficacy (defined as improvements in maximum urinary flow rate [Qmax ] of ≥50%, post-void residual urine volume [PVR] and scores on the International Prostate Symptom Score [IPSS] questionnaire) and safety of urethral sphincter injections of onabotulinumtoxinA in women with a primary disorder of urethral sphincter relaxation, characterised by an elevated urethral pressure profile (UPP) and specific findings at urethral sphincter electromyography (EMG), i.e. Fowler's syndrome. In this open-label pilot Institutional Review Board-approved study, 10 women with a primary disorder of urethral sphincter relaxation (elevated UPP, sphincter volume, and abnormal EMG) presenting with obstructed voiding (five) or in complete urinary retention (five) were recruited from a single tertiary referral centre. Baseline symptoms were assessed using the IPSS, and Qmax and PVR were measured. After 2% lidocaine injection, 100 U of onabotulinumtoxinA was injected into the striated urethral sphincter, divided on either side, under EMG guidance. Patients were reviewed at 1, 4 and 10 weeks after injection, and assessed using the IPSS, Qmax and PVR measurements. The UPP was repeated at week 4. The mean (range) patient age was 40 (25-65) years, and the mean symptom scores on the IPSS improved from 25.6 to 14.1, and the mean 'bother' score reduced from 6.1 to 3.5 at week 10. As compared with a baseline mean Qmax of 8.12 mL/s in the women who could void, the Qmax improved to 15.8 mL/s at week 10. Four of the five women in complete retention could void spontaneously, with a mean Qmax of 14.3 mL/s at week 10. The mean PVR decreased from 260 to 89 mL and the mean static UPP improved from 113 cmH2 O at baseline to 90 cmH2 O. No serious side-effects were reported. Three women with a history of recurrent urinary tract infections developed a urinary tract infection. There were no reports of stress urinary incontinence. Seven of the 10 women opted to return for repeat injections. This pilot study shows an improvement in patient-reported lower urinary tract symptoms, and the objective parameters of Qmax , PVR and UPP, at 10 weeks after urethral sphincter injections of onabotulinumtoxinA. No serious side-effects were reported. This treatment could represent a safe outpatient treatment for young women in retention due to a primary disorder of urethral sphincter relaxation. However, a larger study is required to confirm the findings of this pilot study. © 2015 The Authors BJU International © 2015 BJU International Published by John Wiley & Sons Ltd.

  19. Open vs Laparoscopic Simple Prostatectomy: A Comparison of Initial Outcomes and Cost.

    PubMed

    Demir, Aslan; Günseren, Kadir Ömür; Kordan, Yakup; Yavaşçaoğlu, İsmet; Vuruşkan, Berna Aytaç; Vuruşkan, Hakan

    2016-08-01

    We compared the cost-effectiveness of laparoscopic simple prostatectomy (LSP) vs open prostatectomy (OP). A total of 73 men treated for benign prostatic hyperplasia were enrolled for OP and LSP in groups 1 and 2, respectively. The findings were recorded perioperative, including operation time (OT), blood lost, transfusion rate, conversion to the open surgery, and the complications according to the Clavien Classification. The postoperative findings, including catheterization and drainage time, the amount of analgesic used, hospitalization time, postoperative complications, international prostate symptom score (IPSS) and International Index of Erectile Function (IIEF) scores, the extracted prostate weight, the uroflowmeter, as well as postvoiding residual (PVR) and quality of life (QoL) score at the postoperative third month, were analyzed. The cost of both techniques was also compared statistically. No statistical differences were found in the preoperative parameters, including age, IPSS and QoL score, maximum flow rate (Qmax), PVR, IIEF score, and prostate volumes, as measured by transabdominal ultrasonography. No statistical differences were established in terms of the OT and the weight of the extracted prostate. No differences were established with regard to complications according to Clavien's classification in groups. However, the bleeding rate was significantly lower in group 2. The drainage, catheterization, and hospitalization times and the amount of analgesics were significantly lower in the second group. The postoperative third month findings were not different statistically. Only the Qmax values were significantly greater in group 2. While there was only a $52 difference between groups with regard to operation cost, this difference was significantly different. The use of LSP for the prostates over 80 g is more effective than the OP in terms of OT, bleeding amount, transfusion rates, catheterization time, drain removal time, hospitalization time, consumed analgesic amount, and Qmax values. On the other hand, the mean cost of the LSP is higher than OP. Better effectiveness comes with higher cost.

  20. Photoselective vaporization of the prostate: the basel experience after 108 procedures.

    PubMed

    Bachmann, Alexander; Ruszat, Robin; Wyler, Stephen; Reich, Oliver; Seifert, Helge H; Müller, Alexander; Sulser, Tullio

    2005-06-01

    This study aims to investigate safety and efficacy of 80 watt high-power potassium titanyl phosphate (KTP) laser vaporization of the prostate in men with lower urinary tract symptoms (LUTS) secondary to benign prostatic hyperplasia (BPH). 108 patients underwent 80W KTP laser vaporization. Functional follow-up included measurement of maximum urinary flow rate (Qmax), postvoid residual volume (Vres) and International Prostate Symptom Score (IPSS) within a 12 months period. The average prostate volume was 52.2+/-24.3 ml and the preoperative PSA value was 3.6+/-3.6 ng/dl. Mean operation time was 54.5+/-25.0 min. Qmax increased highly significantly (p<0.001) by 111% (+7.9 ml/s) at discharge, 212% (+15.1 ml/s) after three months, 201% (+14.3 ml/s) after six months and 252% (+17.9 ml/s) after 12 months. Correspondingly, Vres, IPSS and Bother Score improved to an extent that was statistically highly significant (p<0.001) immediately after surgery. The observed complication rate within one year was low. 80 W KTP laser vaporization is a virtually bloodless, safe and effective procedure for surgical treatment of LUTS secondary to BPH. A significant improvement of objective and subjective voiding parameters was observed just after surgery. KTP laser vaporization is associated with a low rate of complications.

  1. Assessment of satisfaction and Quality of Life using self - reported questionnaires after urethroplasty: a prospective analysis

    PubMed Central

    Lucas, Eduardo Terra; Koff, Walter José; Rosito, Tiago Elias; Berger, Milton; Bortolini, Tiago; Silva, Brasil

    2017-01-01

    ABSTRACT Objectives To assess patient satisfaction and quality of life after urethroplasty using two different self-reported outcome measures and to compare it with objective clinical data. Materials and Methods We prospectively collected data from 35 consecutive patients who underwent urethroplasty from January 2013 to September 2014. Patient demographics, International Prostate Symptom Score (IPSS), quality of life score, urethral stricture surgery patient-reported outcome measure (USS-PROM), maximum flow rate (Qmax) and post-void residual urine were collected before, two and eight months after surgery. Failure occurred when any postoperative instrumentation was performed. General estimation equation was used to compare the results and linear regression analysis to correlate both questionnaires with objective data. Results Mean age was 61 years. Urethroplasties were equally divided between anastomotic and buccal mucosa grafts and 19 patients (59.3%) had a previous urethral procedure. Overall success rate was 87.5%. IPSS improved from a mean 19 at baseline to 5.32 at 8 months (p <0.001). The mean USS-PROM score also improved from 13.21 preoperatively to 3.36 after surgery (p <0.001) and 84.3% of patients were satisfied or very satisfied with surgical results. Mean Qmax increased from 4.64mL/s to 11mL/s (p <0.001). Strong negative correlation was found respectively between flow rate and USS-PROM (r=-0.531, p <0.001) and with IPSS (r=-0.512, p <0.001). Conclusions Significant improvements in urinary symptoms and in quality of life are expected after urethroplasty and they are correlated with objective measures. PMID:28128915

  2. Long-term functional outcomes after penoscrotal hypospadias repair: A retrospective comparative study of proximal TIP, Onlay, and Duckett.

    PubMed

    Hueber, Pierre-Alain; Salgado Diaz, Monica; Chaussy, Yann; Franc-Guimond, Julie; Barrieras, Diego; Houle, Anne-Marie

    2016-08-01

    A variety of techniques are available for proximal hypospadias repair. Onlay, proximal tubularized incised plate (TIP), and Duckett are among the popular choices because they can be performed as a one-step procedure. However, the decision to select a procedure often comes down to the surgeon's preference rather than that supported by evidence-based data. In particular, there is a paucity of literature on the long-term urinary outcomes after proximal hypospadias repair. The aim of this study was to evaluate the evolution of long-term uroflowmetry parameters after proximal hypospadias surgery over a long-term follow-up including the adolescent period. Files from patients who underwent primary proximal hypospadias repair at our institution between 1997 and 2001 were reviewed. Only patients with documented serial postoperative uroflowmetry profiles at follow-up visits were included. Comparison between surgeries (pTIP vs. Onlay vs. Duckett) was performed according to the following postoperative time interval endpoints: 0-1 years, 1-2, >2-4, >4-6, >6-10, >10-12, and >12 years. Maximal urinary flow rate (Qmax) in relation to voiding volume (VV) adjusted for age or body surface area (BSA) were also evaluated in comparison to normal children using established Miskolc nomograms and compared between surgery techniques. Fifty-two patients met the inclusion criteria with a median follow-up of 10 years: 25 (59.6%) TIP, 18 (34/6%) Onlay, and nine (17.3%) Duckett. Overall, Qmax increased progressively according to time and age in particular during the period covering adolescence. At follow-up 12 years postoperatively, median Qmax values were 18.5 mL/second, 13.8 mL/second and 16.6 mL/second for TIP, Onlay, and Duckett, respectively, with no significant differenced detected between groups (p = 0.5) see figure). Compared with normal children when adjusted for voiding volume and BSA, the proportion of obstructive uroflowmetry patterns defined as Qmax<25th percentile of nomograms was more prevalent in patients aged 3-7 years old at 83.8% but decreased to less than 21.2% in patients aged >13 years for all procedures (see figure). These results are consistent with previous work showing frequently reduced Qmax after hypospadias surgery with great potential for improvement at puberty. These results suggest that the obstructive urinary flow pattern observed in patients early on is a frequent finding after proximal hypospadias surgery. However, because of the remarkable improvement observed at puberty a watchful waiting approach is proposed in order to avoid unnecessary intervention. Copyright © 2016 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  3. Can preoperative detrusor underactivity influence surgical outcomes of 120 W HPS vaporization of the prostate (PVP) or holmium laser enucleation of the prostate (HoLEP)? A serial 3-year follow-up study.

    PubMed

    Cho, Min Chul; Park, Juhyun; Kim, Jung Kwon; Cho, Sung Yong; Jeong, Hyeon; Oh, Seung-June; Paick, Jae-Seung; Son, Hwancheol

    2018-01-01

    To determine the influence of preoperative detrusor underactivity (DU) on serial long-term outcomes of HPS/PVP or HoLEP for LUTS/BPH, and to compare the influence between the two surgeries. A total of 382 men, who underwent 120W-HPS/PVP or HoLEP for LUTS/BPH and for whom 36-month follow-up data were available, were classified into four groups: HPS with DU (n = 145), HPS without DU (n = 44), HoLEP with DU (n = 105), and HoLEP without DU (n = 88). DU was defined as bladder contractility index of <100. Surgical outcomes were assessed at postoperative 6, 12, 24, and 36 months using IPSS, uroflowmetry, and serum PSA. All four groups maintained improvements in voiding symptom score (VSS), storage symptom score, total-IPSS, QOL index, maximum flow rate (Qmax), post-void residual urine volume (PVR), and bladder voiding efficiency (BVE) compared with baseline up to 3 years postoperatively. There were no significant differences in improvements of postoperative IPSS parameters including QOL index between men with and without DU throughout the follow-up period after HPS or HoLEP. In men with DU, there were no significant differences in improvements of postoperative QOL index, Qmax, PVR, or BVE between HPS and HoLEP groups throughout the follow-up period, except for VSS and total IPSS. Serum PSA reductions after HoLEP were greater than after PVP. Improvements in LUTS, Qmax, and BVE can maintain up to 3 years after HPS or HoLEP for LUTS/BPH, irrespective of the presence or absence of preoperative DU. Although HoLEP may provide more durable improvement of VS in men with DU than HPS, there seems to be no difference in improvement of QOL or Qmax or BVE between HPS and HoLEP. © 2017 Wiley Periodicals, Inc.

  4. Experimental and clinical trial of measuring urinary velocity with the pitot tube and a transrectal ultrasound guided video urodynamic system.

    PubMed

    Tsujimoto, Yukio; Nose, Yorihito; Ohba, Kenkichi

    2003-01-01

    The pitot tube is a common device to measure flow velocity. If the pitot tube is used as an urodynamic catheter, urinary velocity and urethral pressure may be measured simultaneously. However, to our knowledge, urodynamic studies with the pitot tube have not been reported. We experimentally and clinically evaluated the feasibility of the pitot tube to measure urinary velocity with a transrectal ultrasound guided video urodynamic system. We carried out a basal experiment measuring flow velocity in model urethras of 4.5-8.0 mm in inner diameter with a 12-Fr pitot tube. In a clinical trial, 79 patients underwent transrectal ultrasound guided video urodynamic studies with the 12-Fr pitot tube. Urinary velocity was calculated from dynamic pressure (Pd) with the pitot tube formula and the correcting equation according to the results of the basal experiment. Velocity measured by the pitot tube was proportional to the average velocity in model urethras and the coefficients were determined by diameters of model urethras. We obtained a formula to calculate urinary velocity from the basal experiment. The urinary velocity could be obtained in 32 of 79 patients. Qmax was 8.1 +/- 4.3 mL/s (mean +/- SD; range, 18.4-1.3 mL/s), urethral diameter was 7.3 +/- 3.0 mm (mean +/- SD; range, 18.7-4.3 mm) and urinary velocity was 69.4 +/- 43.6 (mean +/- SD; range, 181.3-0 cm/s) at maximum flow rate. The correlation coefficient of Qmax measured by a flowmeter versus Qdv flow rate calculated with urethral diameter and velocity was 0.41 without significant difference. The use of the pitot tube as an urodynamic catheter to a transrectal ultrasound-guided video urodynamic system can measure urethral pressure, diameter and urinary velocity simultaneously. However, a thinner pitot tube and further clinical trials are needed to obtain more accurate results.

  5. Work Capacity of the Bladder During Voiding: A Novel Method to Evaluate Bladder Contractile Function and Bladder Outlet Obstruction

    PubMed Central

    Liu, Ning; Man, Li-Bo; He, Feng; Huang, Guang-Lin; Zhou, Ning; Zhu, Xiao-Fei

    2015-01-01

    Background: Work in voiding (WIV) of the bladder may be used to evaluate bladder status throughout urination rather than at a single time point. Few studies, however, have assessed WIV owing to the complexity of its calculations. We have developed a method of calculating work capacity of the bladder while voiding and analyzed the associations of bladder work parameters with bladder contractile function and bladder outlet obstruction (BOO). Methods: The study retrospectively evaluated 160 men and 23 women, aged >40 years and with a detrusor pressure at maximal flow rate (Pdet Qmax) of ≥40 cmH2O in men, who underwent urodynamic testing. The bladder power integration method was used to calculate WIV; WIV per second (WIV/t) and WIV per liter of urine voided (WIV/v) were also calculated. In men, the relationships between these work capacity parameters and Pdet Qmax and Abrams-Griffiths (AG) number were determined using linear-by-linear association tests, and relationships between work capacity parameters and BOO grade were investigated using Spearman's association test. Results: The mean WIV was 1.15 ± 0.78 J and 1.30 ± 0.88 J, mean WIV/t was 22.95 ± 14.45 mW and 23.78 ± 17.02 mW, and mean WIV/v was 5.59 ± 2.32 J/L and 2.83 ± 1.87 J/L in men and women, respectively. In men, WIV/v showed significant positive associations with Pdet Qmax (r = 0.845, P = 0.000), AG number (r = 0.814, P = 0.000), and Schafer class (r = 0.726, P = 0.000). Conversely, WIV and WIV/t showed no associations with Pdet Qmax or AG number. In patients with BOO (Schafer class > II), WIV/v correlated positively with increasing BOO grade. Conclusions: WIV can be calculated from simple urodynamic parameters using the bladder power integration method. WIV/v may be a marker of BOO grade, and the bladder contractile function can be evaluated by WIV and WIV/t. PMID:26668148

  6. Medium term outcome of bipolar plasma vaporization in prostate cancer patients--a palliative modality of preserving spontaneous voiding.

    PubMed

    Geavlete, B; Moldoveanu, C; Niţă, Gh; Stănescu, F; Jecu, M; Geavlete, P

    2012-12-15

    This retrospective analysis evaluated the efficiency, safety, and medium term postoperative results of bipolar plasma vaporization (BPV) in prostate cancer (PCa) cases associating complete urinary retention. A series of 40 patients diagnosed with locally advanced or metastatic PCa and complete urinary retention requiring a Foley catheter indwelling underwent BPV aiming to restore spontaneous voiding. A total of 35 patients completed the one year evaluation protocol consisting of International Prostate Symptom Score (IPSS), quality of life score (QoL), maximum flow rate (Q(max)) and post-voiding residual urinary volume (PVR), measured at 1, 3, 6 and 12 months after surgery. BPV was successfully performed in all cases with satisfactory efficiency, as confirmed by the mean operation time (42.8 minutes) and hemoglobin drop (0.7 g/dl). A fast and safe postoperative recovery period was described in this series (hematuria rate--7.5%; mean catheterization period--36 hours; mean hospital stay--2.5 days; early-irritative symptoms' rate--15%). At 1, 3, 6 and 12 months, satisfactory values were determined in terms of IPSS, Qmax, QoL and PVR. These parameters emphasized a stable evolution throughout the entire follow-up, as 88.6% of the patients maintained spontaneous voiding. The present trial confirmed the plasma-button vaporization as a promising therapeutic approach in PCa cases associating complete urinary retention. The technique displayed good efficacy, low perioperative morbidity, short convalescence, and satisfactory urodynamics and symptom score parameters during the one-year follow-up period.

  7. Influence of secondary settling tank performance on suspended solids mass balance in activated sludge systems.

    PubMed

    Patziger, M; Kainz, H; Hunze, M; Józsa, J

    2012-05-01

    Secondary settling is the final step of the activated sludge-based biological waste water treatment. Secondary settling tanks (SSTs) are therefore an essential unit of producing a clear effluent. A further important function of SSTs is the sufficient thickening to achieve highly concentrated return sludge and biomass within the biological reactor. In addition, the storage of activated sludge is also needed in case of peak flow events (Ekama et al., 1997). Due to the importance of a high SST performance the problem has long been investigated (Larsen, 1977; Krebs, 1991; Takács et al., 1991; Ekama et al., 1997; Freimann, 1999; Patziger et al., 2005; Bürger et al., 2011), however, a lot of questions are still to solve regarding e.g. the geometrical features (inflow, outflow) and operations (return sludge control, scraper mechanism, allowable maximum values of surface overflow rates). In our study we focused on SSTs under dynamic load considering both the overall unsteady behaviour and the features around the peaks, investigating the effect of various sludge return strategies as well as the inlet geometry on SST performance. The main research tool was a FLUENT-based novel mass transport model consisting of two modules, a 2D axisymmetric SST model and a mixed reactor model of the biological reactor (BR). The model was calibrated and verified against detailed measurements of flow and concentration patterns, sludge settling, accompanied with continuous on-line measurement of in- and outflow as well as returned flow rates of total suspended solids (TSS) and water. As to the inlet arrangement a reasonable modification of the geometry could result in the suppression of the large scale flow structures of the sludge-water interface thus providing a significant improvement in the SST performance. Furthermore, a critical value of the overflow rate (q(crit)) was found at which a pronounced large scale circulation pattern develops in the vertical plane, the density current in such a way hitting the outer wall of the SST, turning then to the vertical direction accompanied with significant flow velocities. This phenomenon strengthens with the hydraulic load and can entrain part of the sludge thus resulting in unfavourable turbid effluent. As a representative case study an operating circular SST most commonly used in practice was investigated. Focusing on the sludge return strategies, it was found that up to a threshold peak flow rate the most efficient way is to keep the return sludge flow rate constant, at 0.4Q(MAX). However, once the inflow rate exceeds the threshold value the return sludge flow rate should be slowly increased up to 0.6Q(MAX), performed in a delayed manner, about 20-30 min after the threshold value is exceeded. For preserving the methodology outlined in the present paper, other types of SSTs, however, need further individual investigations. Copyright © 2012 Elsevier Ltd. All rights reserved.

  8. “U-Method” TVT-Secur Slings: Are they obstructive?

    PubMed Central

    Richard, Patrick; Gagnon, Louis-Olivier; Tu, Le Mai

    2012-01-01

    Introduction: The TVT-Secur, a single incision sling, was introduced in 2006. It is implanted using either the “hammock” or the “U-method” technique. With the latter, the sling is tightened to create a “pillowing effect” on the urethra until a negative stress test is obtained. Short-term results seem promising. However, no study has ever reported on the voiding pattern 12 months after its implantation. Our objective was to assess whether the “U-method” technique creates an obstructive voiding pattern on pressure-flow study (PFS) 12 months after the surgery. Methods: In this retrospective study, we reviewed the charts of 33 women who underwent the “U-method” TVT-Secur. Patients were evaluated before and 12 months postoperatively with regard to different urodynamic studies (UDS). The incontinence status was also assessed 12 months after surgery. Results: At 12 months after the operation, 12.5% (4/32) of the patients reported an improvement of their stress urinary incontinence, while 78.1% (25/32) reported being cured from it. The objective cure rate was 63% (19/30). One patient had a suspected bladder outlet obstruction (BOO) based on PFS. Maximal flow rate (Qmax) was significantly lower 12 months after surgery (26.0 mL/s [range: 19.0–36.5] vs. 21.5 mL/s [range: 16.0–32.3]). However, median voided volume was lower on the postoperative uroflowmetry (446 mL [range: 348–605] vs. 320 mL [range: 243–502]). Furthermore, none of the patients complained of voiding symptoms after surgery. Conclusions: Although one patient had findings compatible with BOO, none complained of voiding symptoms. TVT-Secur may result in a lower Qmax. However, this finding may be due to a lower voiding volume on the postoperative UDS. PMID:22511425

  9. Prospective comparison of a new visual prostate symptom score versus the international prostate symptom score in men with lower urinary tract symptoms.

    PubMed

    van der Walt, Chris L E; Heyns, Chris F; Groeneveld, Adam E; Edlin, Rachel S; van Vuuren, Stephan P J

    2011-07-01

    To evaluate the correlation between the International Prostate Symptom Score (IPSS) and a new Visual Prostate Symptom Score (VPSS) using pictures rather than words to assess lower urinary tract symptoms (LUTS). Four IPSS questions related to frequency, nocturia, weak stream, and quality of life (QoL) were represented by pictograms in the VPSS. Men with LUTS were given the IPSS and VPSS to complete. Peak (Qmax.) and average (Qave.) urinary flow rates were measured. Statistical analysis was performed using Student's t, Fisher's exact, and Spearman's correlation tests. The educational level of the 96 men (mean age 64, range 33-85 years) evaluated August 2009 to August 2010 was school grade 8-12 (62%), grade 1-7 (28%), university education (6%), and no schooling (4%). The IPSS was completed without assistance by 51 of 96 men (53%) and the VPSS by 79 of 96 men (82%) (P<.001). Comparing education grade<7 vs grade>10 groups, the IPSS required assistance in 27 of 31 men (87%) vs 9 of 38 men (24%) (P<.001), and the VPSS required assistance in 10 of 31 men (32%) vs 3 of 38 men (8%) (P=.014). There were statistically significant correlations between total VPSS, Qmax. and Qave., total VPSS and IPSS, and individual VPSS parameters (frequency, nocturia, weak stream and QoL) vs their IPSS counterparts. The VPSS correlates significantly with the IPSS, Qmax. and Qave., and can be completed without assistance by a greater proportion of men with limited education, indicating that it may be more useful than the IPSS in patients who are illiterate or have limited education. Copyright © 2011 Elsevier Inc. All rights reserved.

  10. Thulium laser enucleation (ThuLEP) versus transurethral resection of the prostate in saline (TURis): A randomized prospective trial to compare intra and early postoperative outcomes.

    PubMed

    Bozzini, G; Seveso, M; Melegari, S; de Francesco, O; Buffi, N M; Guazzoni, G; Provenzano, M; Mandressi, A; Taverna, G

    2017-06-01

    To compare clinical intra and early postoperative outcomes between thulium laser transurethral enucleation of the prostate (ThuLEP) and transurethral bipolar resection of the prostate (TURis) for treating benign prostatic hyperplasia (BPH) in a prospective randomized trial. The study randomized 208 consecutive patients with BPH to ThuLEP (n=102) or TURis (n=106). For all patients were evaluated preoperatively with regards to blood loss, catheterization time, irrigation volume, hospital stay and operative time. At 3 months after surgery they were also evaluated by International Prostate Symptom Score (IPSS), maximum flow rate (Qmax), and postvoid residual urine volume (PVR). The patients in each study arm each showed no significant difference in preoperative parameters. Compared with TURIS, ThuLEP had same operative time (53.69±31.44 vs 61.66±18.70minutes, P=.123) but resulted in less hemoglobin decrease (0.45 vs 2.83g/dL, P=.005). ThuLEP also needed less catheterization time (1.3 vs 4.8 days, P=.011), irrigation volume (29.4 vs 69.2 L, P=.002), and hospital stay (1.7 vs 5.2 days, P=.016). During the 3 months of follow-up, the procedures did not demonstrate a significant difference in Qmax, IPSS, PVR, and QOLS. ThuLEP and TURis both relieve lower urinary tract symptoms equally, with high efficacy and safety. ThuLEP was statistically superior to TURis in blood loss, catheterization time, irrigation volume, and hospital stay. However, procedures did not differ significantly in Qmax, IPSS, PVR, and QOLS through 3 months of follow-up. Copyright © 2016 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  11. The Power Coefficient in the Theory of Energy Extraction from Tidal Channels

    NASA Astrophysics Data System (ADS)

    Cummins, P. F.

    2014-12-01

    The maximum average power available from a fence of turbines deployed in a tidal channel is given by the simple formula, Ρ=γρgaQmax, where ρga is the amplitude of pressure difference across ends of the channel, Qmax is the maximum volume flux through the channel in the undisturbed state (i.e., before turbines are deployed), and γ is a numerical coefficient. The latter depends only weakly on the underlying dynamical balance of the channel. This is shown to be consequence of quadratic drag and changes to the natural impedance of the channel as deployment of turbines impedes the flow. Additionally, it is shown that the power coefficient γ is relatively insensitive to the form of the turbine drag.

  12. Intracoronary Adenosine: Dose-Response Relationship With Hyperemia.

    PubMed

    Adjedj, Julien; Toth, Gabor G; Johnson, Nils P; Pellicano, Mariano; Ferrara, Angela; Floré, Vincent; Di Gioia, Giuseppe; Barbato, Emanuele; Muller, Olivier; De Bruyne, Bernard

    2015-09-01

    The present study sought to establish the dosage of intracoronary (IC) adenosine associated with minimal side effects and above which no further increase in flow can be expected. Despite the widespread adoption of IC adenosine in clinical practice, no wide-ranging, dose-response study has been conducted. A recurring debate still exists regarding its optimal dose. In 30 patients, Doppler-derived flow velocity measurements were obtained in 10 right coronary arteries (RCAs) and 20 left coronary arteries (LCAs) free of stenoses >20% in diameter. Flow velocity was measured at baseline and after 8 ml bolus administrations of arterial blood, saline, contrast medium, and 9 escalating doses of adenosine (4 to 500 μg). The hyperemic value was expressed in percent of the maximum flow velocity reached in a given artery (Q/Qmax, %). Q/Qmax did not increase significantly beyond dosages of 60 μg for the RCA and 160 μg for LCA. Heart rate did not change, whereas mean arterial blood pressure decreased by a maximum of 7% (p < 0.05) after bolus injections of IC adenosine. The incidence of transient A-V blocks was 40% after injection of 100 μg in the RCA and was 15% after injection of 200 μg in the LCA. The duration of the plateau reached 12 ± 13 s after injection of 100 μg in the RCA and 21 ± 6 s after the injection of 200 μg in the LCA. A progressive prolongation of the time needed to return to baseline was observed. Hyperemic response after injection of 8 ml of contrast medium reached 65 ± 36% of that achieved after injection of 200 μg of adenosine. This wide-ranging, dose-response study indicates that an IC adenosine bolus injection of 100 μg in the RCA and 200 μg in the LCA induces maximum hyperemia while being associated with minimal side effects. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  13. Efficacy and Safety of the Selective α1A-Adrenoceptor Blocker Silodosin for Severe Lower Urinary Tract Symptoms Associated With Benign Prostatic Hyperplasia: A Prospective, Single-Open-Label, Multicenter Study in Korea

    PubMed Central

    Moon, Ki Hak; Song, Phil Hyun; Yang, Dae Yul; Park, Nam Cheol; Kim, Soo Woong; Lee, Sung Won; Kim, Sae Woong; Moon, Du Geon; Park, Jong Kwan; Ahn, Tai Young

    2014-01-01

    Purpose To evaluate the efficacy and safety of silodosin 8 mg once daily in a 12-week treatment of subjects with severe lower urinary tract symptoms (LUTS) associated with benign prostatic hyperplasia (BPH). Materials and Methods A total of 100 subjects from 10 urology centers in Korea were included in this study. The inclusion criteria were as follows: age ≥50 years, International Prostate Symptom Score (IPSS) ≥20, quality of life (QoL) score ≥3, urine volume ≥120 mL and maximal urinary flow rate (Qmax) <15 mL/s, and postvoid residual volume (PVR) <100 mL. We assessed the improvement of LUTS with change in IPSS, QoL score, Qmax, PVR, and adverse events at baseline and 4 and 12 weeks after treatment with silodosin 8 mg once daily. Results The IPSS values were 23.27±3.34, 15.89±6.26, and 13.80±6.31 at baseline, 4, and 12 weeks, respectively, with significant improvements (p<0.0001, p=0.0214, respectively). QoL scores were 4.44±0.85, 3.38±1.20, and 3.04±1.20 at baseline, 4, and 12 weeks, respectively, and the differences were statistically significant (p<0.0001). There was a significant difference in Qmax between baseline and 12 weeks (p<0.0001) but not in PVR (p=0.9404) during the clinical trial. The most frequent adverse event in this study was ejaculation failure with 13 cases. However, no subject dropped out because of ejaculation failure, and in 12 of the 13 cases it was fully resolved without further treatment. Conclusions Silodosin 8 mg once daily may be effective and safe in Korean patients with severe LUTS associated with BPH. PMID:24868338

  14. Photoselective vaporization of the prostate with GreenLight 120-W laser versus transurethral resection of the prostate for benign prostatic hyperplasia: a systematic review with meta-analysis of randomized controlled trials.

    PubMed

    Zang, Ya-Chen; Deng, Xin-Xi; Yang, Dong-Rong; Xue, Bo-Xin; Xu, Li-Jun; Liu, Xiao-Long; Zhou, Yi-Bin; Shan, Yu-Xi

    2016-02-01

    The aim of this study is to assess the overall efficacy and safety of photoselective vaporization of the prostate (PVP) with GreenLight 120-W laser versus transurethral resection of the prostate (TURP) for treating patients of benign prostate hyperplasia (BPH) with lower urinary tract symptoms (LUTS). We performed a literature search of The Cochrane Library and the electronic databases, including Embase, Medline, and Web of Science. Manual searches were conducted of the conference proceedings, including European Association of Urology and American Urological Association (2007 to 2012). Outcomes reviewed included clinical baseline characteristics, perioperative data, complications, and postoperative functional results, such as postvoid residual (PVR), international prostate symptom score (IPSS), quality of life (QoL), and maximum flow rate (Qmax). Six randomized controlled trials (RCTs) were enrolled. Three hundred and forty-seven patients undergone 120-W PVP, and 350 patients were treated with TURP in the RCTs. There were no significant differences for clinical characteristics in these trials. In perioperative data, catheterization time and length of hospital stay were shorter in the PVP group. However, the operation time was shorter in the TURP group. Capsular perforation, blood transfusion, clot retention, and macroscopic hematuria were markedly less likely in PVP-treated subjects. The other complications between PVP and TURP did not demonstrate a statistic difference. There were no significant differences in QoL, PVR, IPSS, and Qmax in the 1, 3, 6, 12, and 24 months of postoperative follow-up. There was no significant difference at postoperation follow-up of functional outcomes including IPSS, PVR, Qmax, and QoL between the TURP-treated subjects and PVP-treated subjects. Owing to a shorter catheterization time, reduced hospital duration and less complication, PVP could be used as an alternative and a promising minimal invasive surgical procedure for the treatment of BPH.

  15. Diode laser (980 nm) vaporization in comparison with transurethral resection of the prostate for benign prostatic hyperplasia: randomized clinical trial with 2-year follow-up.

    PubMed

    Razzaghi, Mohammad Reza; Mazloomfard, Mohammad Mohsen; Mokhtarpour, Hooman; Moeini, Aida

    2014-09-01

    To compare outcomes of diode laser vaporization of prostate with transurethral resection of the prostate (TURP) as a gold-standard treatment. A total number of 115 patients with benign prostatic hyperplasia underwent TURP and 980-nm diode vaporization of prostate in a balanced randomization (1:1) from 2010 to 2012 and were followed up for 24 months. Baseline characteristics of the patients, perioperative data, and postoperative outcomes were compared. The primary end point of the study was assessing the values of International Prostate Symptom Score (IPSS), and maximum flow rate (Qmax) to predict the functional improvement of each group. The trial is registered at http://www.irct.ir (number IRCT201202138146N3). The mean age (± standard deviation) of the patients was 68.2 ± 7.8 years in TURP and 68.5 ± 8.8 in diode groups. In TURP and diode groups, the operation time was 54.9 ± 15.3 vs 60.6 ± 22.6 minutes (P = .14), Foley catheterization time was 88.9 ± 22.5 vs 20.1 ± 4.6 hours (P = .0001) and postoperative hospital stay was 59.9 ± 14.4 vs 25.8 ± 9.2 hours (P = .0001) respectively. Outcome with regard to increase in Qmax, decrease in IPSS, and decrease in postvoid residual urine volume showed a dramatic improvement in both groups during the first 6 months. In the TURP group, the values of IPSS and Qmax were respectively lower and higher than diode patients at 12 and 24 months of follow-up. According to our study, diode laser vaporization (980 nm) offers a safe and feasible procedure in the management of patients with symptomatic benign prostatic hypertrophy; however, at longer follow-up the functional outcome of diode laser vaporization has been less efficient than TURP. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. Photoselective vaporization of the prostate for the treatment of benign prostatic hyperplasia: 12-month results from the first United States multicenter prospective trial.

    PubMed

    Te, Alexis E; Malloy, Terrence R; Stein, Barry S; Ulchaker, James C; Nseyo, Unyime O; Hai, Mahmood A; Malek, Reza S

    2004-10-01

    We report the 1-year efficacy and safety of photoselective vaporization of the prostate (PVP) for symptomatic and obstructive benign prostatic hyperplasia (BPH). A prospective clinical trial was performed in 139 men clinically diagnosed with symptomatic bladder outlet obstruction secondary to BPH who were enrolled and treated with a high power, 80 W, quasicontinuous wave potassium-titanyl-phosphate laser at 6 American medical centers across the country. Efficacy parameters were mean and percent changes from baseline in the American Urological Association Symptom Index (AUA-SI) score, quality of life score (QOL), peak urinary flow rate (Qmax), post-void residual urine volume (PVR) and transrectal ultrasound prostate volume measurement. Patients were evaluated 1, 3, 6 and 12 months following treatment. At each followup evaluation side effects were elicited. Significant improvements in AUA-SI score, QOL score, Qmax and PVR were noted as early as 1 month after PVP treatment. At 12 months the mean AUA-SI score decreased from 23.9 to 4.3 (p <0.0001) and the QOL score decreased from 4.3 to 1.1 (p <0.0001), while mean Qmax increased from 7.8 to 22.6 ml per second (p <0.0001). PVR decreased from 114.3 to 24.8 ml (p <0.0001), while the transrectal ultrasound volume reduction went from 54.6 ml at baseline to 34.4 ml. There was no significant blood loss or fluid absorption during or immediately after PVP. Complications consisted of transient hematuria, dysuria and urinary retention in 12 (8.6%), 13 (9.3%) and 7 (5%) patients, respectively. PVP is a unique, safe and effective outpatient modality that provides immediate symptomatic and urodynamic relief of bladder outlet obstruction secondary to BPH. Long-term followup is needed to validate further the maintenance of clinical efficacy beyond 1 year.

  17. Five-Year Follow-Up Study of Transurethral Plasmakinetic Resection of the Prostate for Benign Prostatic Hyperplasia.

    PubMed

    Hu, Yangyang; Dong, Xuecheng; Wang, Guangchun; Huang, Jianhua; Liu, Min; Peng, Bo

    2016-01-01

    To explore the long-term clinical efficacy and safety of transurethral plasmakinetic resection of the prostate (PKRP) for benign prostatic hyperplasia (BPH). A total of 550 patients with BPH who had undergone PKRP from October 2006 to September 2009 were enrolled in this study. All patients were evaluated at baseline and follow-up (3, 12, 24, 36, 48, 60 months postoperatively) by peak flow rate (Qmax), postvoid residual (PVR), quality of life (QoL), International Prostate Symptom Score (IPSS), and Overactive Bladder Symptom Score (OABSS). Operative details and postoperative complications regarded as safety outcomes were documented. A total of 467 patients completed the 5-year follow-up. The mean duration of surgery was 36.43 minutes, mean catheterization time was 48.81 hours, mean hospital stay was 4.21 days. At 60 months postoperatively, the mean Qmax increased from 6.94 mL/s at baseline to 19.28 mL/s, the mean PVR decreased from 126.33 mL to 10.45 mL, the mean IPSS score decreased from 15.79 to 7.51, the mean QoL score decreased from 4.36 to 1.91, and the mean OABSS score decreased from 6.39 to 3.65 (P < 0.001), respectively. In perioperative complications, the blood transfusion rate was 2.7%, urinary tract infection rate was 3.6%; no transurethral resection syndrome (TUR syndrome) occurred. In late complications, urethral stricture rate was 5.4%, recurrent bladder outlet obstruction rate was 2.1%, and the reoperation rate was 4.5%. PKRP is based on conventional monopolar transurethral resection of the prostate (TURP) and uses a bipolar plasmakinetic system. Our results indicate that the long-term clinical efficacy and safety of PKRP for BPH are remarkable. In particular, the incidence of urethral stricture, recurrent bladder outlet obstruction, and reoperation is low. We suggest that PKRP is a reliable minimally invasive technique that may be the preferred procedure for the treatment of patients with BPH.

  18. Operational Constraints on Hydropeaking and its Effects on the Hydrologic and Thermal Regime of a River in Central Chile

    NASA Astrophysics Data System (ADS)

    Olivares, M. A.; Guzman, C.; Rossel, V.; De La Fuente, A.

    2013-12-01

    Hydropower accounts for about 44% of installed capacity in Chile's Central Interconnected System, which serves most of the Chilean population. Hydropower reservoir projects can affect ecosystems by changing the hydrologic regime and water quality. Given its volumen regulation capacity, low operation costs and fast response to demand fluctuations, reservoir hydropower plants commonly operate on a load-following or hydropeaking scheme. This short-term operational pattern produces alterations in the hydrologic regime downstream the reservoir. In the case of thermally stratified reservoirs, peaking operations can affect the thermal structure of the reservoir, as well as the thermal regime downstream. In this study, we assessed the subdaily hydrologic and thermal alteration donwstream of Rapel reservoir in Central Chile for alternative operational scenarios, including a base case and several scenarios involving minimum instream flow (Qmin) and maximum hourly ramping rates (ΔQmax). Scenarios were simulated for the stratification season of summer 2009-2012 in a grid-wide short-term economic dispatch model which prescribes hourly power production by every power plant on a weekly horizon. Power time series are then translated into time series of turbined flows at each hydropower plants. Indicators of subdaily hydrologic alteration (SDHA) were computed for every scenario. Additionally, turbined flows were used as input data for a three-dimensional hydrodynamic model (CWR-ELCOM) of the reservoir which simulated the vertical temperature profile in the reservoir and the outflow temperature. For the time series of outflow temperatures we computed several indicators of subdaily thermal alteration (SDTA). Operational constraints reduce the values of both SDHA and SDTA indicators with respect to the base case. When constraints are applied separately, the indicators of SDHA decrease as each type of constraint (Qmin or ΔQmax) becomes more stringent. However, ramping rate constraints proved more effective than minimun instream flows. Combined constraints produced even better results. Results for the indicators of SDTA follow a similar trend than that of SDHA. More restrictive operations result in lower values for the indicators. However, the impact of the different constraint scenarios is smaller, as results look alike for all scenarios. Moreover, due to the mixing conditions associated to the operational schemes, mean temperatures increased with respect to the unconstrained case.

  19. [Silodosin therapy for lower urinary tract symptoms in men with suspected benign prostatic hyperplasia: results of an international, randomized, double-blind, placebo- and active-controlled clinical trial performed in Europe].

    PubMed

    Chapple, Ch R; Montorsi, F; Tammela, T L J; Wirth, M; Koldewijn, E; Fernandez Fernandez, E

    2012-01-01

    Silodosin is a new selective therapy with a high pharmacologic selectivity for the a (1A)-adrenoreceptor. Our aim was to test silodosin's superiority to placebo and noninferiority to tamsulosin and discuss the findings in the context of a comprehensive literature review of the new compound silodosin. We conducted a multicenter double-blind, placebo-and active-controlled parallel group study. A total of 1228 men > or = 50 yr of age with an International Prostate Symptom Score (IPSS) < or = 13 and a urine maximum flow rate (Q(max))> 4 and < or = 15 ml/s were selected at 72 sites in 11 European countries. The patients were entered into a 2-wk wash-out and a 4-wk placebo run-in period. A total of 955 patients were randomized (2:2:1) to silodosin 8 mg (n = 381), tamsulosin 0.4 mg (n = 384), or placebo (n = 190) once daily for 12 wk. We calculated the change from baseline in IPSS total score (primary), storage and voiding subscores, quality of life (QoL) due to urinary symptoms, and Q(max). Responders were defined on the basis of IPSS and Q(max) by a decrease of > or = 25% and an increase of > or = 30% from baseline, respectively. The change from baseline in the IPSS total score with silodosin and tamsulosin was significantly superior to that with placebo (p < 0.001): difference active placebo of -2.3 (95% confidence interval [CI], -3.2, -1.4) with silodosin and -2.0 (95% CI, -2.9, -1.1) with tamsulosin. Responder rates according to total IPSS were significantly higher (p < 0.001) with silodosin (66.8%) and tamsulosin (65.4%) than with placebo (50.8%). Active treatments were also superior to placebo in the IPSS storage and voiding subscore analyses, as well as in QoL due to urinary symptoms. Of note, only silodosin significantly reduced nocturia versus placebo (the change from baseline was -0.9, -0.8, and -0.7 for silodosin, tamsulosin, and placebo, respectively; p = 0.013 for silodosin vs placebo). An increase in Q(max) was observed in all groups. The adjusted mean change from baseline to end point was 3.77 ml/s for silodosin, 3.53 ml/s for tamsulosin, and 2.93 ml/s for placebo, but the change for silodosin and tamsulosin was not statistically significant versus placebo because of a particularly high placebo response (silodosin vs placebo: p = 0.089; tamsulosin vs placebo: p = 0.221). At end point, the percentage of responders by Q(max) was 46.6%, 46.5%, and 40.5% in the silodosin, tamsulosin, and placebo treatment groups, respectively. This difference was not statistically significant (p = 0.155 silodosin vs placebo and p = 0.141 tamsulosin vs placebo). Active treatments were well tolerated, and discontinuation rates due to adverse events were low in all groups (2.1%, 1.0%, and 1.6% with silodosin, tamsulosin, and placebo, respectively). The most frequent adverse event with silodosin was a reduced or absent ejaculation during orgasm (14%), a reversible effect as a consequence of the potent and selective a(1A)-adrenoreceptor antagonism of the drug. The incidence was higher than that observed with tamsulosin (2%); however, only 1.3% of silodosin-treated patients discontinued treatment due to this adverse event. Silodosin is an effective and well-tolerated treatment for the relief of both voiding and storage symptoms in patients with lower urinary tract symptoms suggestive of bladder outlet obstruction thought to be associated with benign prostatic hyperplasia. Its overall efficacy is not inferior to tamsulosin. Only silodosin showed a significant effect on nocturia over placebo.

  20. Silodosin therapy for lower urinary tract symptoms in men with suspected benign prostatic hyperplasia: results of an international, randomized, double-blind, placebo- and active-controlled clinical trial performed in Europe.

    PubMed

    Chapple, Christopher R; Montorsi, Francesco; Tammela, Teuvo L J; Wirth, Manfred; Koldewijn, Evert; Fernández Fernández, Eldiberto

    2011-03-01

    Silodosin is a new selective therapy with a high pharmacologic selectivity for the α(1A)-adrenoreceptor. Our aim was to test silodosin's superiority to placebo and noninferiority to tamsulosin and discuss the findings in the context of a comprehensive literature review of the new compound silodosin. We conducted a multicenter double-blind, placebo- and active-controlled parallel group study. A total of 1228 men ≥50 yr of age with an International Prostate Symptom Score (IPSS) ≥13 and a urine maximum flow rate (Q(max)) >4 and ≤15 ml/s were selected at 72 sites in 11 European countries. The patients were entered into a 2-wk wash-out and a 4-wk placebo run-in period. A total of 955 patients were randomized (2:2:1) to silodosin 8 mg (n=381), tamsulosin 0.4 mg (n=384), or placebo (n=190) once daily for 12 wk. We calculated the change from baseline in IPSS total score (primary), storage and voiding subscores, quality of life (QoL) due to urinary symptoms, and Q(max). Responders were defined on the basis of IPSS and Q(max) by a decrease of ≥25% and an increase of ≥30% from baseline, respectively. The change from baseline in the IPSS total score with silodosin and tamsulosin was significantly superior to that with placebo (p<0.001): difference active placebo of -2.3 (95% confidence interval [CI], -3.2, -1.4) with silodosin and -2.0 (95% CI,-2.9, -1.1) with tamsulosin. Responder rates according to total IPSS were significantly higher (p<0.001) with silodosin (66.8%) and tamsulosin (65.4%) than with placebo (50.8%). Active treatments were also superior to placebo in the IPSS storage and voiding subscore analyses, as well as in QoL due to urinary symptoms. Of note, only silodosin significantly reduced nocturia versus placebo (the change from baseline was -0.9, -0.8, and -0.7 for silodosin, tamsulosin, and placebo, respectively; p=0.013 for silodosin vs placebo). An increase in Q(max) was observed in all groups. The adjusted mean change from baseline to end point was 3.77 ml/s for silodosin, 3.53 ml/s for tamsulosin, and 2.93 ml/s for placebo, but the change for silodosin and tamsulosin was not statistically significant versus placebo because of a particularly high placebo response (silodosin vs placebo: p=0.089; tamsulosin vs placebo: p=0.221). At end point, the percentage of responders by Q(max) was 46.6%, 46.5%, and 40.5% in the silodosin, tamsulosin, and placebo treatment groups, respectively. This difference was not statistically significantly (p=0.155 silodosin vs placebo and p=0.141 tamsulosin vs placebo). Active treatments were well tolerated, and discontinuation rates due to adverse events were low in all groups (2.1%, 1.0%, and 1.6% with silodosin, tamsulosin, and placebo, respectively). The most frequent adverse event with silodosin was a reduced or absent ejaculation during orgasm (14%), a reversible effect as a consequence of the potent and selective α(1A)-adrenoreceptor antagonism of the drug. The incidence was higher than that observed with tamsulosin (2%); however, only 1.3% of silodosin-treated patients discontinued treatment due to this adverse event. Silodosin is an effective and well-tolerated treatment for the relief of both voiding and storage symptoms in patients with lower urinary tract symptoms suggestive of bladder outlet obstruction thought to be associated with benign prostatic hyperplasia. Its overall efficacy is not inferior to tamsulosin. Only silodosin showed a significant effect on nocturia over placebo. ClinicalTrials.gov Identifier NCT00359905. Copyright © 2010 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  1. Does age affect the efficacy and safety of GreenLight HPS™ laser photoselective vaporization prostatectomy?

    PubMed

    Gu, Xiao; Strom, Kurt; Spaliviero, Massimiliano; Wong, Carson

    2012-03-01

    To evaluate the efficacy and safety of GreenLight HPS(™) (High Performance System) laser photoselective vaporization prostatectomy (PVP) for the treatment of benign prostatic hyperplasia (BPH) in patients of different age groups. 164 consecutive patients were stratified into two groups: age <70 (group I, n = 93) and age ≥70 (group II, n = 71) years. Transurethral PVP was performed using a GreenLight HPS™ side-firing laser system. Voiding parameters were measured preoperatively and at 1 and 4 weeks and 3, 6, 12, 18, 24 and 36 months postoperatively. Among the preoperative parameters evaluated, there were significant differences (p < 0.05) in prostate volume (I: 58.7; II: 73.6 mL) and serum prostate-specific antigen (I: 1.9; II: 2.9 ng/mL), while American Urological Association Symptom Score (AUASS), Quality of Life (QoL), maximum flow rate (Qmax), Sexual Health Inventory for Men (SHIM) and post void residual (PVR) were similar (p > 0.05) between groups. No significant differences in laser utilization, energy usage and operating time were noted. Clinical outcomes (AUASS, QoL, Qmax, PVR) showed immediate and stable improvement from baseline (p < 0.05) within each group, but no significant differences between the two groups were observed during the follow-up period. The incidence of adverse events was low and similar in both groups. The results suggest that age has little effect on the efficacy and safety of GreenLight HPS™ laser PVP.

  2. The effectiveness of transcutaneous electrical neural stimulation therapy in patients with urinary incontinence resistant to initial medical treatment or biofeedback.

    PubMed

    Tugtepe, H; Thomas, D T; Ergun, R; Kalyoncu, A; Kaynak, A; Kastarli, C; Dagli, T E

    2015-06-01

    While there are many options for children with treatment refractory urinary incontinence, there is no single accepted method. This study's aim was to prospectively evaluate the effect of transcutaneous electrical nerve stimulation in children with urinary incontinence resistant to standard medical, urological therapy and/or biofeedback. This study was performed at a university hospital. For inclusion, patients >5 years of age first underwent evaluation with urinary ultrasonography, uroflow-electromyogram and voiding diaries. Treatment with biofeedback, alpha adrenergic blockers, anticholinergics and/or urotherapy was commenced according to uroflow-EMG and voiding diary findings. Patients with partial or no response to this standard therapy were then included in this study, performed between April 2012 and February 2014. Patients with anatomical or neurological causes for urinary incontinence were excluded. TENS was performed on S3 dermatome, every day for 3 months. Each session lasted 20 min with a frequency of 10 Hz and generated pulse of 350 μs. Intensity was determined by the child's sensitivity threshold. Medical treatment and urological therapy was continued during TENS. Uroflow parameters (voiding volume as percentage of expected bladder capacity, Qmax, Qave, flow and voiding time, postvoiding residual urine) and urinary system symptoms (presence of urinary tract infection, frequency, urge incontinence, fractionated voiding and constipation) were compared immediately before commencement and immediately after the completion of 3 months of TENS. Twenty-seven patients were included in this study (4 males, 23 females). Patients' average age was 7.2 years, 11 had overactive bladder and 16 had dysfunctional voiding. Comparison of urinary system symptoms and uroflow parameters before and after TENS are shown in Table. After 3 months of TENS; a statistically significant decrease was observed in the number of patients with frequency, urge incontinence, urinary tract infections and constipation. There was a decrease in the number of patients with fractionated voiding, although this change was not statistically significant. Similarly, for uroflow-EMG parameters; bladder capacity, Qmax, Qave and flow time increased while voiding time and PVR decreased. Changes seen in bladder capacity, Qmax and PVR were statically significant, while other changes were not. Patients' response rates after 3 months of TENS were; complete response in 70.4%, partial response in 22.2% and no response in 7.4%. This study has shown that transcutaneous electrical nerve stimulation is a promising treatment option for standard-treatment refractory children with urinary incontinence. Copyright © 2015 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  3. Silodosin is effective for treatment of LUTS in men with BPH: a systematic review

    PubMed Central

    Ding, Hui; Du, Wan; Hou, Zi-Zhen; Wang, Han-Zhang; Wang, Zhi-Ping

    2013-01-01

    The aim of this study was to systematically review the evidence on the efficacy and safety of silodosin treatments on lower urinary tract symptoms (LUTS) in men with benign prostatic hyperplasia (BPH) from randomized controlled trials. We searched PubMed (1966–December 2011), Embase (1974–December 2011) and the Cochrane Library Database (2011, Issue 12). The assessed outcome measures were the change from baseline for the International Prostate Symptom Score (IPSS), quality of life (QoL) score, peak urine maximum flow rate (Qmax), QoL related to urinary symptoms and adverse effects. Two authors independently assessed the study quality and extracted data. All data were analysed using RevMan 5.1. The meta-analysis included four randomized controlled trials with a total of 2504 patients. The study durations were each 12 weeks. At the follow-up end points, the pooled results showed that the change from baseline for the silodosin group was significantly higher than the placebo group for the IPSS, QoL score and Qmax(mean difference (MD)=−2.78, P<0.00001; MD=−0.42, P=0.004; MD=1.17, P<0.00001,respectively) and patients felt more satisfied with QoL related to urinary symptoms in the silodosin group than the placebo group. Ejaculation disorder was the most commonly reported adverse effect. The pooled results also showed that the silodosin group was superior to the 0.2 mg tamsulosin group with respect to the IPSS and QoL score (IPSS: MD=−1.14, P=0.02; QoL score: MD=−0.26, P=0.02) and inferior to the 0.2 mg tamsulosin group with respect to Qmax (MD=−0.85, P=0.01). In contrast, there was no significant difference in the incidence of ejaculation disorder and dizziness between the silodosin and 0.2 mg tamsulosin groups. The current meta-analysis suggested that silodosin is an effective therapy for LUTS in men with BPH and is not inferior to 0.2 mg tamsulosin. PMID:23223034

  4. A randomized, comparative, open-label study of efficacy and tolerability of alfuzosin, tamsulosin and silodosin in benign prostatic hyperplasia

    PubMed Central

    Manjunatha, R.; Pundarikaksha, H. P.; Madhusudhana, H. R.; Amarkumar, J.; Hanumantharaju, B. K.

    2016-01-01

    Objectives: Benign prostatic hyperplasia (BPH) is a common and progressive disease affecting elderly males, often associated with lower urinary tract symptoms (LUTS). α1-blockers are the mainstay in symptomatic therapy of BPH. Because of their greater uroselectivity and minimal hemodynamic effects, alfuzosin, tamsulosin, and silodosin are generally preferred. The aim of this study was to compare the efficacy and tolerability of alfuzosin, tamsulosin, and silodosin in patients with BPH and LUTS. Methods: Ninety subjects with BPH and LUTS were randomized into three groups of thirty in each, to receive alfuzosin sustained release (SR) 10 mg, tamsulosin 0.4 mg, or silodosin 8 mg for 12 weeks. The primary outcome measure was a change in the International Prostate Symptom Score (IPSS), and the secondary outcome measures were changes in individual subjective symptom scores, quality of life score (QLS), and peak flow rate (Qmax) from baseline. The treatment response was monitored at 2, 4, 8, and 12 weeks. Results: IPSS improved by 88.18%, 72.12%, and 82.23% in alfuzosin SR, tamsulosin and silodosin groups (P < 0.001) at 12 weeks. Improvement in QLS was >75% in all the three groups (P < 0.001). A significant improvement in Qmax was seen with alfuzosin and tamsulosin (P = 0.025 and P < 0.001) but not with silodosin (P = 0.153). However, the intergroup differences in IPSS, QLS, and Qmax were not significant. Ejaculatory dysfunction was more common with silodosin and corrected QT (QTc) prolongation occurred only with alfuzosin (two subjects) and tamsulosin (three subjects). Conclusion: Alfuzosin, tamsulosin, and silodosin showed similar efficacy in improvement of LUTS secondary to BPH, with good tolerability, acceptability, and minimum hemodynamic adverse effects. Alfuzosin, tamsulosin, and silodosin are comparable in efficacy in symptomatic management of BPH. The occurrence of QTc prolongation in three subjects with tamsulosin in the present study is an unexpected adverse event as there are no reports of QTc prolongation with tamsulosin in any of the previous studies. PMID:27127315

  5. The efficacy of mirabegron additional therapy for lower urinary tract symptoms after treatment with α1-adrenergic receptor blocker monotherapy: prospective analysis of elderly men.

    PubMed

    Matsuo, Tomohiro; Miyata, Yasuyoshi; Kakoki, Katsura; Yuzuriha, Miki; Asai, Akihiro; Ohba, Kojiro; Sakai, Hideki

    2016-07-29

    Mirabegron is a β3-adrenoreceptor agonist developed for treatment of overactive bladder (OAB). α1-Adrenergic receptor blockers are effective for lower urinary tract symptoms (LUTS) in male patients. However, the efficacy of mirabegron additional treatment in elderly male patients with persistent male LUTS, especially in OAB after monotherapy with α1-adrenergic blockers, is not fully understood. This study was conducted in male LUTS patients who were ≥ 65 years of age and had persistent OAB symptoms, regardless of whether they took an α1-adrenergic receptor blocker orally. Before and 12 weeks after mirabegron additional therapy (50 mg once daily), we evaluated the efficacy of this treatment using the Overactive Bladder Symptom Score (OABSS) and International Prostate Symptom Score (IPSS), and changes in the maximum flow rate (Qmax) and post-void residual urine volume (PVR). We evaluated patients overall and divided into two groups by age: young-old (from 65 to 74 years old) and old-old (from 75 to 84 years old). Fifty men were enrolled in this study. Mirabegron additional therapy improved the total OABSS, total IPSS, and IPSS-quality of life (QOL) score. The voided volume (VV) and Qmax improved after treatment in patients overall. However, there was no significant change in PVR. The total OABSS, total IPSS, and IPSS-QOL score significantly improved in both of the young-old and old-old groups. However, a significant increasing of VV was detected in the young-old group. There were no significant differences in the Qmax or PVR in either group. Mirabegron additional therapy was effective for male patients whose persistent LUTS and particularly OAB was not controlled with α1-adrenergic receptor blocker monotherapy, and mirabegron did not have negative effects on voiding function. Additionally, mirabegron additional therapy was considered effective regardless of patient age. Trial registration number (TRN) trial registration number (TRN) and date of registration: ISRCTN16759097 in July 8, 2016.

  6. Use of selenium-silymarin mix reduces lower urinary tract symptoms and prostate specific antigen in men.

    PubMed

    Vostalova, Jitka; Vidlar, Ales; Ulrichova, Jitka; Vrbkova, Jana; Simanek, Vilim; Student, Vladimir

    2013-12-15

    The aim of this double-blind, placebo controlled clinical trial was to assess the effects of a combination of selenium and silymarin in men with lower urinary tract symptoms, benign prostatic hyperplasia and a prostate specific antigen (PSA) ≤2.5ng/ml. The volunteers were randomized to two groups: the first one (n=26) received 240μg selenium (in the form of yeast l-selenomethionine) plus 570mg silymarin daily for 6 months and the second (n=29) received placebo. Outcome measures were changes in the International Prostate Symptom Score (IPSS), bladder volume (V), urinary flow rate, ultrasound estimated postvoid residual urine volume (RV), serum PSA, testosterone and selenium levels, safety clinical biochemistry, hematology and oxidative stress parameters at baseline and on day 180. The results showed statistically significant differences (p<0.05) between treatment and control groups for the following parameters: IPSS score, urodynamic parameters: maximal rate of urine flow (Qmax), average flow (Qave), V and RV, total PSA value and serum selenium levels. There was a significant reduction in PSA in the selenium-silymarin group but no effect on blood testosterone level. Overall the treatment was well-tolerated with no adverse effects. Copyright © 2013 Elsevier GmbH. All rights reserved.

  7. Definition of normality of pressure-flow parameters based on observations in asymptomatic men.

    PubMed

    Rosario, Derek J; Woo, Henry H; Chapple, Christopher R

    2008-01-01

    Clinical nomograms for differentiating obstructed from unobstructed voiding and poor detrusor contractility from normal contractility have traditionally been drawn on the basis of symptomatic response to outflow tract surgery or on urodynamic changes in men with LUTS before and after surgery. The aim of this study was to examine pressure-flow parameters in asymptomatic male volunteers before age-related changes in the lower urinary tract had taken place and to assess detrusor contractility and outflow conditions during physiological bladder filling against clinically used pressure-flow nomograms. Thirty-seven healthy male subjects between the ages of 18 and 40 years volunteered to undergo AUM. A total of 66 fill-void cycles in 25 individuals were evaluable. Mean p(det.Qmax) for the group was 53 +/- 3 cmH(2)O with a mean Q(max) of 24 +/- 2 ml sec(-1). URA of 21 cmH(2)O defined the upper border of normality for the outflow condition. Schäfer's OCO showed the most consistent relationship between estimated urethral pressure at minimal flow and true measured urethral closure pressure. From a clinical perspective, the linear nomograms (ICS and Schäfer) are more easily accessible with the ICS BOOI and obstruction index being the simplest to calculate manually. Minimal differences found between these urodynamic nomograms confirm the clinical value of recommending a single method to facilitate future comparisons between studies. An upper limit of normality for the male outflow condition can be defined by an URA of 21 cmH(2)O, AGN of 40 cmH(2)O or OCO of 1. Results above these reference values should be considered abnormal in this age group and where identified in a different age-group should be explained by physiological or pathophysiological events.

  8. Clinical and Biochemical Influence of Prostatic Stones.

    PubMed

    Soric, Tomislav; Selimovic, Mirnes; Bakovic, Lada; Šimurina, Tatjana; Selthofer, Robert; Dumic, Jerka

    2017-01-01

    The study aimed to explore clinical influence of prostatic stones on lower urinary tract symptoms (LUTS), seminal plasma cytokines, and serum biomarkers. A total of 70 men aged ≤50 years with LUTS divided into 2 groups: group with stones (GSt) and group without prostatic stones (GNoSt). All subjects completed the International Prostate Symptom Score (IPSS) questionnaire and National Institutes of Health Chronic Prostatitis Symptom Index (NIH-CPSI) scoring questionnaire. Pre- and post-prostate massage test and uroflowmetry were performed. The serum concentration of total prostate specific antigen (PSA), free PSA, and free/total PSA (f/t PSA) ratio, seminal concentration of cytokines interleukin (IL)-1β, IL-6, IL-8, IL-10, IL-12p70, and tumor necrosis factor-alpha were measured. GSt subjects had significantly more severe symptoms based on IPSS answers (p = 0.0289). All domains in NIH-CPSI scores were significantly higher in the GSt group: pain (p = 0.001), urinary symptoms (p = 0.023), quality of life (p = 0.008), and with overall (p = 0.003). GSt subjects also had significantly lower maximum urinary flow (Qmax; p = 0.011), lower f/t PSA ratio (p = 0.048), and higher concentration of IL-1β (p = 0.011) and IL-8 (p = 0.001). Prostatic stones may influence the severity of LUTS and the symptoms of chronic prostatitis. They might reduce Qmax rate and lead to reduction of the f/t PSA ratio and produce more severe inflammation causing increased seminal concentration of IL-1β and IL-8. © 2017 S. Karger AG, Basel.

  9. Temporary implantable nitinol device (TIND): a novel, minimally invasive treatment for relief of lower urinary tract symptoms (LUTS) related to benign prostatic hyperplasia (BPH): feasibility, safety and functional results at 1 year of follow-up.

    PubMed

    Porpiglia, Francesco; Fiori, Cristian; Bertolo, Riccardo; Garrou, Diletta; Cattaneo, Giovanni; Amparore, Daniele

    2015-08-01

    To report the first clinical experience with a temporary implantable nitinol device (TIND; Medi-Tate(®) ) for the treatment of lower urinary tract symptoms (LUTS) due to benign prostatic hyperplasia (BPH). In all, 32 patients with LUTS were enrolled in this prospective study, which was approved by our Institutional Ethics Committee. Inclusion criteria were: age >50 years, International Prostate Symptom Score (IPSS) of ≥10, maximum urinary flow rate (Qmax ) of ≤12 mL/s, and prostate volume of <60 mL. The TIND was implanted within the bladder neck and the prostatic urethra under light sedation, using a rigid cystoscope. The device was removed 5 days later in an outpatient setting. Demographics, perioperative results, complications (according to the Clavien system), functional results and quality of life (QoL) were evaluated. Follow-up assessments were made at 3 and 6 weeks, and 3, 6 and 12 months postoperatively. The Student's t-test, analysis of variance (anova), Kruskall-Wallis test, and simple and multiple linear regression models were used in the statistical analyses. The mean patient age was 69.4 years, the mean (standard deviation, sd) prostate volume was 29.5 (7.4) mL and the Qmax was 7.6 (2.2) mL/s. The median (interquartile range, IQR) IPSS was 19 (14-23) and QoL score was 3 (3-4). All the implantations were successful, with no intraoperative complications recorded. The mean operative time (sd) was 5.8 (2.5) min and the median (IQR) postoperative stay was 1 (1-2) day. All but one of the devices (96%) was removed 5 days at after implantation in an outpatient setting. Four complications (12.5%) were recorded, including urinary retention (one, 3.1%), transient incontinence due to device displacement (one, 3.1%), prostatic abscess (one, 3.1%), and urinary tract infection (one, 3.1%). Multiple regression analysis failed to identify any independent prognostic factor for complications. There were statistically significant differences in the IPSS, QoL score and Qmax when comparing pre- and postoperative results at every time point. After 12 months, the median (IQR) IPSS and QoL score were 9 (7-13) and 1 (1-2), respectively, and the mean (sd) Qmax was 12 (4.7) mL/s. The mean variations with respect to baseline conditions at the same time points were -45% for the IPSS and +67% for Qmax . At 12 months after surgery (last follow-up visit), no patients required medical therapy or surgical procedures for BPH. TIND implantation is a feasible and safe minimally invasive option for the treatment of BPH-related LUTS. The functional results are encouraging and the treatment significantly improved patient QoL. Further studies are required to assess durability of TIND results and to optimise the indications of such a procedure. © 2014 The Authors BJU International © 2014 BJU International Published by John Wiley & Sons Ltd.

  10. Endurance training and maximal oxygen consumption with ageing: Role of maximal cardiac output and oxygen extraction.

    PubMed

    Montero, David; Díaz-Cañestro, Candela

    2016-05-01

    The increase in maximal oxygen consumption (VO2max) with endurance training is associated with that of maximal cardiac output (Qmax), but not oxygen extraction, in young individuals. Whether such a relationship is altered with ageing remains unclear. Therefore, we sought systematically to review and determine the effect of endurance training on and the associations among VO2max, Qmax and arteriovenous oxygen difference at maximal exercise (Ca-vO2max) in healthy aged individuals. We conducted a systematic search of MEDLINE, Scopus and Web of Science, from their inceptions until May 2015 for articles assessing the effect of endurance training lasting 3 weeks or longer on VO2max and Qmax and/or Ca-vO2max in healthy middle-aged and/or older individuals (mean age ≥40 years). Meta-analyses were performed to determine the standardised mean difference (SMD) in VO2max, Qmax and Ca-vO2max between post and pre-training measurements. Subgroup and meta-regression analyses were used to evaluate the associations among SMDs and potential moderating factors. Sixteen studies were included after systematic review, comprising a total of 153 primarily untrained healthy middle-aged and older subjects (mean age 42-71 years). Endurance training programmes ranged from 8 to 52 weeks of duration. After data pooling, VO2max (SMD 0.89; P < 0.0001) and Qmax (SMD 0.61; P < 0.0001) were increased after endurance training; no heterogeneity among studies was detected. Ca-vO2max was only increased with endurance training interventions lasting more than 12 weeks (SMD 0.62; P = 0.001). In meta-regression, the SMD in Qmax was positively associated with the SMD in VO2max (B = 0.79, P = 0.04). The SMD in Ca-vO2max was not associated with the SMD in VO2max (B = 0.09, P = 0.84). The improvement in VO2max following endurance training is a linear function of Qmax, but not Ca-vO2max, through healthy ageing. © The European Society of Cardiology 2015.

  11. Endurance Training and V˙O2max: Role of Maximal Cardiac Output and Oxygen Extraction.

    PubMed

    Montero, David; Diaz-Cañestro, Candela; Lundby, Carsten

    2015-10-01

    Although endurance training (ET) commonly augments maximal oxygen consumption (V˙O2max), it remains unclear whether such increase is associated with that of maximal cardiac output (Qmax) alone or along with arteriovenous oxygen difference (a-V˙O2diff). Herein, we sought to systematically review and determine the effects of ET on V˙O2max, Qmax, and a-V˙O2diff at maximal exercise, and on their associations, in healthy young subjects. We conducted a systematic search of MEDLINE, Scopus, and Web of Science (from their inception until September 2014) for articles assessing the effects of ET lasting ≥3 wk on V˙O2max and Qmax and/or a-V˙O2diff at maximal exercise in healthy young adults (mean age <40 yr). Meta-analyses were performed to determine standardized mean differences (SMD) in V˙O2max, Qmax, and a-V˙O2diff at maximal exercise between posttraining and pretraining measurements. Subgroup and meta-regression analyses were used to evaluate associations among SMD and potential moderating factors. Thirteen studies were included after systematic review, comprising a total of 130 untrained or moderately trained healthy young subjects (mean age, 22-28 yr). Duration of ET programs ranged from 5 to 12.9 wk. After data pooling, V˙O2max (SMD = 0.75, P < 0.0001) and Qmax (SMD = 0.64, P < 0.0001), but not a-V˙O2diff at maximal exercise (SMD = 0.21, P = 0.23), were increased after ET. No significant heterogeneity was detected. With meta-regression, the SMD in Qmax was positively associated with the SMD in V˙O2max (B = 0.91, P = 0.007). The SMD in a-V˙O2diff at maximal exercise was not associated with the SMD in V˙O2max (B = 0.20, P = 0.40). Based on a relatively small number of studies, improvement in V˙O2max following 5-13 wk of ET is associated with increase in Qmax, but not in a-V˙O2diff, in previously untrained to moderately trained healthy young individuals.

  12. Multiscale entropy-based methods for heart rate variability complexity analysis

    NASA Astrophysics Data System (ADS)

    Silva, Luiz Eduardo Virgilio; Cabella, Brenno Caetano Troca; Neves, Ubiraci Pereira da Costa; Murta Junior, Luiz Otavio

    2015-03-01

    Physiologic complexity is an important concept to characterize time series from biological systems, which associated to multiscale analysis can contribute to comprehension of many complex phenomena. Although multiscale entropy has been applied to physiological time series, it measures irregularity as function of scale. In this study we purpose and evaluate a set of three complexity metrics as function of time scales. Complexity metrics are derived from nonadditive entropy supported by generation of surrogate data, i.e. SDiffqmax, qmax and qzero. In order to access accuracy of proposed complexity metrics, receiver operating characteristic (ROC) curves were built and area under the curves was computed for three physiological situations. Heart rate variability (HRV) time series in normal sinus rhythm, atrial fibrillation, and congestive heart failure data set were analyzed. Results show that proposed metric for complexity is accurate and robust when compared to classic entropic irregularity metrics. Furthermore, SDiffqmax is the most accurate for lower scales, whereas qmax and qzero are the most accurate when higher time scales are considered. Multiscale complexity analysis described here showed potential to assess complex physiological time series and deserves further investigation in wide context.

  13. Chloride Anions Regulate Kinetics but Not Voltage-Sensor Qmax of the Solute Carrier SLC26a5.

    PubMed

    Santos-Sacchi, Joseph; Song, Lei

    2016-06-07

    In general, SLC26 solute carriers serve to transport a variety of anions across biological membranes. However, prestin (SLC26a5) has evolved, now serving as a motor protein in outer hair cells (OHCs) of the mammalian inner ear and is required for cochlear amplification, a mechanical feedback mechanism to boost auditory performance. The mechanical activity of the OHC imparted by prestin is driven by voltage and controlled by anions, chiefly intracellular chloride. Current opinion is that chloride anions control the Boltzmann characteristics of the voltage sensor responsible for prestin activity, including Qmax, the total sensor charge moved within the membrane, and Vh, a measure of prestin's operating voltage range. Here, we show that standard narrow-band, high-frequency admittance measures of nonlinear capacitance (NLC), an alternate representation of the sensor's charge-voltage (Q-V) relationship, is inadequate for assessment of Qmax, an estimate of the sum of unitary charges contributed by all voltage sensors within the membrane. Prestin's slow transition rates and chloride-binding kinetics adversely influence these estimates, contributing to the prevalent concept that intracellular chloride level controls the quantity of sensor charge moved. By monitoring charge movement across frequency, using measures of multifrequency admittance, expanded displacement current integration, and OHC electromotility, we find that chloride influences prestin kinetics, thereby controlling charge magnitude at any particular frequency of interrogation. Importantly, however, this chloride dependence vanishes as frequency decreases, with Qmax asymptoting at a level irrespective of the chloride level. These data indicate that prestin activity is significantly low-pass in the frequency domain, with important implications for cochlear amplification. We also note that the occurrence of voltage-dependent charge movements in other SLC26 family members may be hidden by inadequate interrogation timescales, and that revelation of such activity could highlight an evolutionary means for kinetic modifications within the family to address hearing requirements in mammals. Copyright © 2016 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  14. [Associating Serenoa repens, Urtica dioica and Pinus pinaster. Safety and efficacy in the treatment of lower urinary tract symptoms. Prospective study on 320 patients].

    PubMed

    Pavone, C; Abbadessa, D; Tarantino, M L; Oxenius, I; Laganà, A; Lupo, A; Rinella, M

    2010-01-01

    Serenoa repens (saw palmetto) has been employed for the treatment of lower urinary tract symptoms (LUTS) for several years. Its mechanism of action is believed to be due to antiandrogenic, antiproliferative and antinflammatory properties. An association of Serenoa with the nettle "Urtica dioica" showing antiproliferative activity and the pine "Pinus pinaster" derivative, showing antinflammatory action, has been proposed in recent years. Such an action is hoped to act not only by reducing LUTS but also by preventing the development of prostate cancer. During the years 2007 and 2008, 320 patients suffering from LUTS were treated with an association of Serenoa repens 320 mg, Urtica dioica 120 mg and Pinus pinaster 5 mg, named IPBTRE. This treatment was administered to all patients for a minimal duration of 30 days to a maximum of a year, either alone or in association with antibiotics or alpha-blockers, if needed. Outcome analysis was based on evaluation of symptoms, prostate volume and maximum flow rate (Qmax). From a careful analysis of the data collected in our database, the following observations can be made: ages varied between 19 and 78 years. The patients were affected by BPH in 46% of cases, chronic prostatitis syndrome in 43%, chronic genital-pelvic pain in 7% and other conditions in 4%, the absolute numbers being 147, 138, 22 and 7 patients, respectively. No untoward side effect was reported in any case. Variations in symptom score could be fully evaluated only in 80 of 320 patients (25%), of whom 68 (85%) reported a significant benefit, with special reference to an improvement of pain, urgency, strangury and nocturia. Data on variations in prostate volume, as measured by digital rectal examination, were available in 84 (26.5%) patients. No significant change was observed. Qmax after treatment was measured in 83 (26%) patients. It did not show significant changes from the initial values. The association tested in our study appeared to be safe and well tolerated. No changes in flow rate and prostate volume were observed, but a marked reduction of LUTS was observed in 85% of evaluable cases, especially with regard to pain and irritative symptoms. Whether or not such an association may display a prevention of prostate cancer, may be investigated in additional studies.

  15. Urtica dioica for treatment of benign prostatic hyperplasia: a prospective, randomized, double-blind, placebo-controlled, crossover study.

    PubMed

    Safarinejad, Mohammad Reza

    2005-01-01

    To determine the effects of therapy with Urtica dioica for symptomatic relief of lower urinary tract symptoms (LUTS) secondary to benign prostatic hyperplasia (BPH). A 6-month, double-blind, placebo-controlled, randomized, partial crossover, comparative trial of Urtica dioica with placebo in 620 patients was conducted. Patients were evaluated using the International Prostate Symptom Score (IPSS), the maximum urinary flow rate (Qmax), postvoid residual urine volume (PVR), Serum Prostatic- Specific Antigen (PSA), testosterone levels, and prostate size. At the end of 6-month trial, unblinding revealed that patients who initially received the placebo were switched to Urtica dioica. Both groups continued the medication up to 18 months. 558 patients (90%) completed the study (287/305, 91% in the Urtica dioica group, and 271/315, 86% in the placebo group). By intention- to-treat analysis, at the end of 6-month trial, 232 (81%) of 287 patients in the Urtica dioica group reported improved LUTS compared with 43 (16%) of 271 patients in the placebo group (P < 0.001). Both IPSS and Qmax showed greater improvement with drug than with placebo. The IPSS went from 19.8 down to 11.8 with Urtica dioica and from 19.2 to 17.7 with placebo (P = 0.002). Peak flow rates improved by 3.4 mL/s for placebo recipients and by 8.2 mL/s for treated patients (P < 0.05). In Urtica dioica group, PVR decreased from an initial value of 73 to 36 mL (P < 0.05). No appreciable change was seen in the placebo group. Serum PSA and testosterone levels were unchanged in both groups. A modest decrease in prostate size as measured by transrectal ultrasonography (TRUS) was seen in Urtica dioica group (from 40.1 cc initially to 36.3 cc; P < 0.001). There was no change in the prostate volume at the end of study with placebo. At 18-month follow-up, only patients who continued therapy, had a favorable treatment variables value. No side effects were identified in either group. In the present study, Urtica dioica have beneficial effects in the treatment of symptomatic BPH. Further clinical trials should be conducted to confirm these results before concluding that Urtica dioica is effective.

  16. Is Tamsulosin 0.2 mg Effective and Safe as a First-Line Treatment Compared with Other Alpha Blockers?: A Meta-Analysis and a Moderator Focused Study

    PubMed Central

    Shim, Sung Ryul; Chang, In Ho; Shin, In Soo; Hwang, Sung Dong; Kim, Khae Hwan; Yoon, Sang Jin; Song, Yun Seob

    2016-01-01

    Purpose Tamsulosin 0.2 mg is used widely in Asian people, but the low dose has been studied less than tamsulosin 0.4 mg or other alpha blockers of standard dose. This study investigated the efficacy and safety of tamsulosin 0.2 mg by a meta-analysis and meta-regression. Materials and Methods We conducted a meta-analysis of efficacy of tamsulosin 0.2 mg using International Prostate Symptom Score (IPSS), maximal urinary flow rate (Qmax), post-voided residual volume (PVR), and quality of life (QoL). Safety was analyzed using adverse events. Relevant studies were searched using MEDLINE, EMBASE, and Cochrane library from January 1980 to June 2013. Results Ten studies were included with a total sample size of 1418 subjects [722 tamsulosin 0.2 mg group and 696 other alpha-blockers (terazosin, doxazosin, naftopidil, silodosin) group]. Study duration ranged from 4 to 24 weeks. The pooled overall standardized mean differences (SMD) in the mean change of IPSS from baseline for the tamsulosin group versus the control group was 0.02 [95% confidence interval (CI); -0.20, 0.25]. The pooled overall SMD in the mean change of QoL from baseline for the tamsulosin group versus the control group was 0.16 (95% CI; -0.16, 0.48). The regression analysis with the continuous variables (number of patients, study duration) revealed no significance in all outcomes as IPSS, QoL, and Qmax. Conclusion This study clarifies that tamsulosin 0.2 mg has similar efficacy and fewer adverse events compared with other alpha-blockers as an initial treatment strategy for men with lower urinary tract symptoms. PMID:26847294

  17. Efficacy and Safety of Initial Combination Treatment of an Alpha Blocker with an Anticholinergic Medication in Benign Prostatic Hyperplasia Patients with Lower Urinary Tract Symptoms: Updated Meta-Analysis.

    PubMed

    Kim, Hyun Jung; Sun, Hwa Yeon; Choi, Hoon; Park, Jae Young; Bae, Jae Hyun; Doo, Seung Whan; Yang, Won Jae; Song, Yun Seob; Ko, Young Myoung; Kim, Jae Heon

    2017-01-01

    There is still controversy as to whether initial combination treatment is superior to serial addition of anticholinergics after maintenance or induction of alpha blockers in benign prostatic hyperplasia (BPH)/lower urinary tract symptoms (LUTS). The objective of this study was to determine the benefits and safety of initial combination treatment of an alpha blocker with anticholinergic medication in BPH/LUTS through a systematic review and meta-analysis. We conducted a meta-analysis of improvement in LUTS using International Prostate Symptom Score (IPSS), maximal urinary flow rate (Qmax), post-voided residual volume (PVR), and quality of life (QoL). In total, 16 studies were included in our analysis, with a total sample size of 3,548 subjects (2,195 experimental subjects and 1,353 controls). The mean change in total IPSS improvement from baseline in the combination group versus the alpha blocker monotherapy group was -0.03 (95% CI: -0.14-0.08). The pooled overall SMD change of storage IPSS improvement from baseline was -0.28 (95% CI: -0.40 - -0.17). The pooled overall SMD changes of QoL, Qmax, and PVR were -0.29 (95% CI: -0.50 - -0.07), 0.00 (95% CI: -0.08-0.08), and 0.56 (95% CI: 0.23-0.89), respectively. There was no significant difference in the number of acute urinary retention (AUR) events or PVR. Initial combination treatment of an alpha blocker with anticholinergic medication is efficacious for in BPH/ LUTS with improved measures such as storage symptoms and QoL without causing significant deterioration of voiding function.

  18. Efficacy and Safety of Initial Combination Treatment of an Alpha Blocker with an Anticholinergic Medication in Benign Prostatic Hyperplasia Patients with Lower Urinary Tract Symptoms: Updated Meta-Analysis

    PubMed Central

    Kim, Hyun Jung; Sun, Hwa Yeon; Choi, Hoon; Park, Jae Young; Bae, Jae Hyun; Doo, Seung Whan; Yang, Won Jae; Song, Yun Seob; Ko, Young Myoung

    2017-01-01

    Background There is still controversy as to whether initial combination treatment is superior to serial addition of anticholinergics after maintenance or induction of alpha blockers in benign prostatic hyperplasia (BPH)/lower urinary tract symptoms (LUTS) Objective The objective of this study was to determine the benefits and safety of initial combination treatment of an alpha blocker with anticholinergic medication in BPH/LUTS through a systematic review and meta-analysis. Methods We conducted a meta-analysis of improvement in LUTS using International Prostate Symptom Score (IPSS), maximal urinary flow rate (Qmax), post-voided residual volume (PVR), and quality of life (QoL). Results In total, 16 studies were included in our analysis, with a total sample size of 3,548 subjects (2,195 experimental subjects and 1,353 controls). The mean change in total IPSS improvement from baseline in the combination group versus the alpha blocker monotherapy group was -0.03 (95% CI: -0.14–0.08). The pooled overall SMD change of storage IPSS improvement from baseline was -0.28 (95% CI: -0.40 - -0.17). The pooled overall SMD changes of QoL, Qmax, and PVR were -0.29 (95% CI: -0.50 - -0.07), 0.00 (95% CI: -0.08–0.08), and 0.56 (95% CI: 0.23–0.89), respectively. There was no significant difference in the number of acute urinary retention (AUR) events or PVR. Conclusions Initial combination treatment of an alpha blocker with anticholinergic medication is efficacious for in BPH/ LUTS with improved measures such as storage symptoms and QoL without causing significant deterioration of voiding function. PMID:28072862

  19. Comparative Study Using 100-300 Versus 300-500 μm Microspheres for Symptomatic Patients Due to Enlarged-BPH Prostates.

    PubMed

    Gonçalves, Octavio Meneghelli; Carnevale, Francisco Cesar; Moreira, Airton Mota; Antunes, Alberto Azoubel; Rodrigues, Vanessa Cristina; Srougi, Miguel

    2016-10-01

    The purpose of the study was to compare safety and efficacy outcomes following prostate artery embolization (PAE) for the treatment of lower urinary tract symptoms (LUTS) due to benign prostatic hyperplasia (BPH) with 100-300 versus 300-500 μm tris-acryl gelatin microspheres. Patients were prospectively treated between August 2011 and June 2013 to receive PAE with 100-300 μm (group A) or 300-500 μm (group B) tris-acryl gelatin microspheres. Patients were followed for a minimum of 12 months and were assessed for changes in International Prostate Symptom Score (IPSS), quality of life (QoL) index, prostate volume determined by magnetic resonance imaging, serum prostate specific antigen (PSA), and maximum urine flow rate (Qmax), as well as any treatment-related adverse events. Fifteen patients were included in each group, and PAE was technically successful in all cases. Both groups experienced significant improvement in mean IPSS, QoL, prostate volume, PSA, and Qmax (p < 0.05 for all). The differences observed between the two groups included a marginally insignificant more adverse events (p = 0.066) and greater mean serum PSA reduction at 3 months of follow-up (p = 0.056) in group A. Both 100-300 and 300-500 μm microspheres are safe and effective embolic agents for PAE to treat LUTS-related to BPH. Although functional and imaging outcomes did not differ significantly following use of the two embolic sizes, the greater incidence of adverse events with 100-300 μm microspheres suggests that 300-500 μm embolic materials may be more appropriate.

  20. GreenLight HPS laser 120-W versus diode laser 200-W vaporization of the prostate: comparative clinical experience.

    PubMed

    Chiang, Po Hui; Chen, Chien Hsu; Kang, Chih Hsiung; Chuang, Yao Chi

    2010-09-01

    We present our clinical experiences of two recently introduced vaporization laser systems: the GreenLight High Performance System (HPS) laser (532 nm, 120 W) and the Diolas LFD diode laser (980 nm, 200 W). Two laser systems were evaluated to compare their clinical results for the treatment of benign prostatic hyperplasia (BPH). Patients were treated using either the GreenLight HPS laser (n = 84) or the diode laser (n = 55) in a prospective randomized study. The data of International Prostate Symptom Score (IPSS), maximum flow rate (Q(max)), post-void residual urine (PVR), and quality of life score (Qols) were recorded at baseline, 1-, 6-, and 12-month follow-ups. The prostate volume and prostate-specific antigen (PSA) level were assessed at baseline and 6-month follow-up. All complications were also recorded. There was a statistically significant difference in IPSS, Q(max), PVR, and QoLs in each laser group at the 1-, 6-, and 12-month follow-ups compared with baseline. There was no statistical significant difference in any of these parameters at any follow-up interval between each group. The diode laser demonstrates superior hemostatic properties compared with the GreenLight HPS laser. Postoperative incontinence and postoperative irritative symptoms are more pronounced (P < 0.05) after diode laser prostatectomy. Higher incidence of dysuria with sloughing tissues and epididymitis (P < 0.05) is noted after diode laser prostatectomy. Other complications were comparable for both procedures. Although both lasers can improve subjective and objective parameters of BPH, both can produce undesired effects. The search for the ideal vaporization laser to treat BPH still continues. 2010 Wiley-Liss, Inc.

  1. Sorption of organic carbon compounds to the fine fraction of surface and Subsurface Soils

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jagadamma, Sindhu; Mayes, Melanie; Zinn, Yuri

    2014-01-01

    Dissolved organic carbon (DOC) transported from the soil surface is stabilized in deeper soil profiles by physicochemical sorption processes. However, it is unclear how different forms of organic carbon (OC) compounds common in soil organic matter interact with soil minerals in the surface (A) and subsurface (B) horizons. We added four compounds (glucose, starch, cinnamic acid and stearic acid) to the silt- and clay-sized fraction (fine fraction) of A and B horizons of eight soils from varying climates (3 temperate, 3 tropical, 1 arctic and 1 sub-arctic). Equilibriumbatch experiments were conducted using 0 to 100 mg C L 1 ofmore » 14C-labeled compounds for 8 h. Sorption parameters (maximum sorption capacity, Qmax and binding coefficient, k) calculated by fitting sorption data to the Langmuir equation showed that Qmax of A and B horizons was very similar for all compounds. Both Qmax and k values were related to sorbate properties, with Qmax being lowest for glucose (20 500 mg kg 1), highest for stearic acid (20,000 200,000 mg kg 1), and intermediate for both cinnamic acid (200 4000 mg kg 1) and starch (400 6000 mg kg 1). Simple linear regression analysis revealed that physicochemical properties of the sorbents influenced the Qmax of cinnamic acid and stearic acid, but not glucose and starch. The sorbent properties did not show predictive ability for binding coefficient k. By using the fine fraction as sorbent, we found that the mineral fractions of A horizons are equally reactive as the B horizons irrespective of soil organic carbon content.« less

  2. [TURP plus endocrine therapy (ET) versus α1A-blockers plus ET for bladder outlet obstruction in advanced prostate cancer].

    PubMed

    Tao, Ling-song; Tao, Liang-jun; Chen, Yi-sheng; Zou, Bin; Zhu, Guang-biao; Wang, Jia-wei; Liang, Chao-zhao

    2015-07-01

    To compare the effect of transurethral resection of the prostate combined with endocrine therapy (TURP + ET) with that of αlA-blockers combined with ET ((αlA-b + ET) in the treatment of bladder outlet obstruction (BOO) in patients with advanced prostate cancer (PCa), and to investigate the safety of the TURP + ET for the treatment of PCa with BOO. We retrospectively analyzed 63 cases of PCa with BOO, 28 treated by αlA-b + ET and the other 35 by TURP + ET. We obtained the residual urine volume (RV), maximum urinary flow rate (Qmax), International Prostate Symptom Score (IPSS), and quality of life score (QoL) before and after treatment along with the overall survival rate of the patients, followed by comparison of the parameters between the two methods. At 3 months after treatment, RV, IPSS, and QoL in the TURP + ET group were significantly decreased from (137.8 ± 27.6) ml, (22.3 ± 3.6), and (4.2 ± 0.8) to (29 ± 13.6) ml, (7.8 ± 2.1), and (1.6 ± 0.5) respectively (P < 0.05), while Qmax increased from (5.6 ± 2.1) ml/s to (17.6 ± 2.7) ml/s (P < 0.05); the former three parameters in the αlA-b + ET group decreased from (133.6 ± 24.9) ml, (21.5 ± 3.2), and (4.7 ± 1.1) to (42 ± 18.3) ml, (12.8 ± 2.6), and (2.5 ± 0.7) respectively (P < 0.05), while the latter one increased from (6.3 ± 2.4) ml/s to (11.7 ± 2.3) ml/s (P < 0.05), all with statistically significant differences between the two groups (P < 0.05). The overall survival rate of the TURP + ET group was not significantly different from that of the αlA-b + ET group (51.4% vs 46.4% , P > 0.05). TURP + ET is preferable to αlA-b + ET for its advantage of relieving BOO symptoms in advanced PCa without affecting the overall survival rate of the patients.

  3. Kinetic parameters for nutrient enhanced crude oil biodegradation in intertidal marine sediments

    PubMed Central

    Singh, Arvind K.; Sherry, Angela; Gray, Neil D.; Jones, D. Martin; Bowler, Bernard F. J.; Head, Ian M.

    2014-01-01

    Availability of inorganic nutrients, particularly nitrogen and phosphorous, is often a primary control on crude oil hydrocarbon degradation in marine systems. Many studies have empirically determined optimum levels of inorganic N and P for stimulation of hydrocarbon degradation. Nevertheless, there is a paucity of information on fundamental kinetic parameters for nutrient enhanced crude oil biodegradation that can be used to model the fate of crude oil in bioremediation programmes that use inorganic nutrient addition to stimulate oil biodegradation. Here we report fundamental kinetic parameters (Ks and qmax) for nitrate- and phosphate-stimulated crude oil biodegradation under nutrient limited conditions and with respect to crude oil, under conditions where N and P are not limiting. In the marine sediments studied, crude oil degradation was limited by both N and P availability. In sediments treated with 12.5 mg/g of oil but with no addition of N and P, hydrocarbon degradation rates, assessed on the basis of CO2 production, were 1.10 ± 0.03 μmol CO2/g wet sediment/day which were comparable to rates of CO2 production in sediments to which no oil was added (1.05 ± 0.27 μmol CO2/g wet sediment/day). When inorganic nitrogen was added alone maximum rates of CO2 production measured were 4.25 ± 0.91 μmol CO2/g wet sediment/day. However, when the same levels of inorganic nitrogen were added in the presence of 0.5% P w/w of oil (1.6 μmol P/g wet sediment) maximum rates of measured CO2 production increased more than four-fold to 18.40 ± 1.04 μmol CO2/g wet sediment/day. Ks and qmax estimates for inorganic N (in the form of sodium nitrate) when P was not limiting were 1.99 ± 0.86 μmol/g wet sediment and 16.16 ± 1.28 μmol CO2/g wet sediment/day respectively. The corresponding values for P were 63 ± 95 nmol/g wet sediment and 12.05 ± 1.31 μmol CO2/g wet sediment/day. The qmax values with respect to N and P were not significantly different (P < 0.05). When N and P were not limiting Ks and qmax for crude oil were 4.52 ± 1.51 mg oil/g wet sediment and 16.89 ± 1.25 μmol CO2/g wet sediment/day. At concentrations of inorganic N above 45 μmol/g wet sediment inhibition of CO2 production from hydrocarbon degradation was evident. Analysis of bacterial 16S rRNA genes indicated that Alcanivorax spp. were selected in these marine sediments with increasing inorganic nutrient concentration, whereas Cycloclasticus spp. were more prevalent at lower inorganic nutrient concentrations. These data suggest that simple empirical estimates of the proportion of nutrients added relative to crude oil concentrations may not be sufficient to guarantee successful crude oil bioremediation in oxic beach sediments. The data we present also help define the maximum rates and hence timescales required for bioremediation of beach sediments. PMID:24782848

  4. Long-term efficacy of Serenoa repens treatment in patients with mild and moderate symptomatic benign prostatic hyperplasia.

    PubMed

    Sinescu, Ioanel; Geavlete, Petrisor; Multescu, Razvan; Gangu, Constantin; Miclea, Florin; Coman, Ioan; Ioiart, Ioan; Ambert, Valentin; Constantin, Traian; Petrut, Bogdan; Feciche, Bogdan

    2011-01-01

    The study aimed to evaluate the long-term efficacy of treatment with extract of Serenoa repens (Prostamol Uno) in patients with lower urinary tract symptoms (LUTS) induced by benign prostatic hyperplasia (BPH). We studied 120 patients with mild or moderate LUTS induced by BPH, maximal urinary flow (Q(max)) <15 ml with a voided volume ≥150 ml, prostate-specific antigen <4 ng/ml, and residual urinary volume <150 ml, treated daily for 24 months with one capsule of 320 mg ethanolic extract of Serenoa repens. Statistically significant improvements in the International Prostate Symptom Score (5.5 points), quality of life (QoL; 1.8 points), Q(max) (5.6 ml/s), International Index of Erectile Function (IIEF; 6.4 points) and reduction in residual urinary volume were observed during the study period. The mean prostate volume at 24 months was 36 ml, compared to 39.8 ml at baseline. Long-term treatment with 320 mg ethanolic extract of Serenoa repens proved to be efficient in reducing urinary obstruction, improving symptomatology and QoL of BPH patients. It also had a positive effect on sexual function, demonstrated by the statistically significant increase in the IIEF. Copyright © 2011 S. Karger AG, Basel.

  5. Serenoa repens, lycopene and selenium versus tamsulosin for the treatment of LUTS/BPH. An Italian multicenter double-blinded randomized study between single or combination therapy (PROCOMB trial).

    PubMed

    Morgia, Giuseppe; Russo, Giorgio I; Voce, Salvatore; Palmieri, Fabiano; Gentile, Marcello; Giannantoni, Antonella; Blefari, Franco; Carini, Marco; Minervini, Andrea; Ginepri, Andrea; Salvia, Giuseppe; Vespasiani, Giuseppe; Santelli, Giorgio; Cimino, Sebastiano; Allegro, Rosalinda; Collura, Zaira; Fragalà, Eugenia; Arnone, Salvatore; Pareo, Rosaria M

    2014-11-01

    Phytotherapy has been used to treat patients with lower urinary tract symptoms (LUTS). We evaluated the efficacy and tolerability of combination therapy between Serenoa Repens (SeR), Lycopene (Ly), and Selenium (Se) + tamsulosin versus single therapies. PROCOMB trial (ISRCTN78639965) was a randomized double-blinded, double-dummy multicenter study of 225 patients between 55 and 80 years old, PSA ≤ 4 ng/ml, IPSS ≥12, prostate volume ≤60 cc, Qmax ≤15 ml/sec, postvoid residual urine (PVR) <150 ml. Participants were randomized group A (SeR-Se-Ly), group B (tamsulosin 0.4 mg), group C (SeR-Se-Ly + tamsulosin 0.4 mg). The primary endpoints of the study were the reduction of IPSS, PVR, and increase of Qmax in group C versus monotherapy groups. The decrease for combination therapy was significantly greater versus group A (P < 0.05) and group B (P < 0.01) for IPSS and versus group A (P < 0.01) for PVR from baseline to 6 months. A greater decrease in IPSS was observed for Group C versus group A (P < 0.01) and increase in Qmax versus group B (P < 0.01), from 6 months to 12 months. At one year, the changes of IPSS and Qmax were greater for Group C versus monotherapies (each comparison <0.05). The proportions of men with a decrease of at least three points (each comparison P < 0.05) and decrease of 25% for IPSS (each comparison P < 0.01) were greater for Group C. SeR-Se-Ly + tamsulosin therapy is more effective than single therapies in improving IPSS and increasing Qmax in patients with LUTS. © 2014 Wiley Periodicals, Inc.

  6. The binding of glucose and nucleotides to hexokinase from Saccharomyces cerevisiae.

    PubMed

    Woolfitt, A R; Kellett, G L; Hoggett, J G

    1988-01-29

    The binding of glucose, ADP and AdoPP[NH]P, to the native PII dimer and PII monomer and the proteolytically-modified SII monomer of hexokinase (ATP:D-hexose 6-phosphotransferase, EC 2.7.1.1) from Saccharomyces cerevisiae was monitored at pH 6.7 by the concomitant quenching of protein fluorescence. The data were analysed in terms of Qmax, the maximal quenching of fluorescence at saturating concentrations of ligand, and [L]0.5, the concentration of ligand at half-maximal quenching. No changes in fluorescence were observed with free enzyme and nucleotide alone. In the presence of saturating levels of glucose, Qmax induced by nucleotide was between 2 and 7%, and [L]0.5 was between 0.12 and 0.56 mM, depending on the nucleotide and enzyme species. Qmax induced by glucose alone was between 22 and 25%, while [L]0.5 was approx. 0.4 mM for either of the monomeric hexokinase forms and 3.4 for PII dimer. In the presence of 6 mM ADP or 2 mM AdoPP[NH]P, Qmax for glucose was increased by up to 4% and [L]0.5 was diminished 3-fold for hexokinase PII monomer, 6-fold for SII monomer, and 15-fold for PII dimer. The results are interpreted in terms of nucleotide-induced conformational change of hexokinase in the presence of glucose and synergistic binding interactions between glucose and nucleotide.

  7. [Effect of modified Badenoch operation on the treatment of posterior urethral stricture].

    PubMed

    Wang, Ping-xian; Zhang, Gen-pu; Huang, Chi-bing; Fan, Ming-qi; Feng, Jia-yu; Xiao, Ya

    2012-02-01

    To determine the effects of modified pull-through operation (Badenoch operation) on the treatment of posterior urethral stricture. From September 2001 to December 2010 traditional pull-through operation was Modified for two times in our center. A total of 129 patients with posttraumatic posterior urethral stricture resulting from pelvic fracture injury underwent the modified urethral pull-through operation. Stricture length was 1.5 to 5.3 cm (mean 2.9 cm). Of the patients 43 had undergone at least 1 previous failed management for stricture. In phase 1 (from September 2001 to January 2008), the improving items include: (1) The distal urethral end was stitched and tied to the catheter. (2) As catheter was inserted into bladder and 20 ml water was injected into catheter balloon, the distal urethral end was fixed in the proximal urethra and an overlaying of 1.5 cm was formed between the two ends. (3) Three weeks later, it was tried to insert the catheter to bladder. After the urethral stump necrosis and the catheter separating from the urethra, the catheter was removed. In phase 2 (from February 2008 to December 2010), based on the above, irrigating catheter was used. After the surgery, urethra was irrigated with 0.02% furacillin solution through the catheter 3 times a day. All patients were followed up for at least 6 months. If patients had no conscious dysuria and maximum urinary flow rate (Qmax) > 15 ml/s, the treatment was considered successful. All complications were recorded. In phase 1, the 96 patients (101 times) underwent the procedure. The treatment was successful in 88 patients (success rate 92%). Within 1 to 13 days after removal of the catheter, urethral stricture was recurred in 8 patients. They had to undergo cystostomy once more for 3 to 11 months before reoperation (the 3 patients' reoperation was in phase 2). The 8 cases were treated successfully. In phase 2, 33 patients (total 36 times) underwent the procedure. One patient was failed (success rate 97%). The actual follow-up time is 7 to 93 months (An average of 37.6 months). Qmax is (22 ± 5) ml/s. No complications such as urinary incontinence, erectile pain, urinary shortening happened. The modified urethral pull-through operation is effective for the surgical treatment of posttraumatic posterior urethral stricture. It has a high success rate with durable long-term results. Complications are few. The procedure is simple, less demanding and especially suitable in patients who had previously undergone failed surgical treatments.

  8. Efficacy and safety of a hexanic extract of Serenoa repens (Permixon® ) for the treatment of lower urinary tract symptoms associated with benign prostatic hyperplasia (LUTS/BPH): Systematic review and meta-analysis of randomized controlled trials and observational studies.

    PubMed

    Vela-Navarrete, Remigio; Alcaraz, Antonio; Rodríguez-Antolín, Alfredo; Miñana López, Bernardino; Fernández-Gómez, Jesús M; Angulo, Javier C; Castro Díaz, David; Romero-Otero, Javier; Brenes, Francisco J; Carballido, Joaquín; Molero García, José M; Fernández-Pro Ledesma, Antonio; Cózar Olmos, José Manuel; Manasanch Dalmau, José; Subirana Cachinero, Isaac; Herdman, Michael; Ficarra, Vincenzo

    2018-04-25

    To comprehensively evaluate the efficacy and safety of the hexanic extract of Serenoa repens (HESr, Permixon), at a dose of 320 mg daily, as monotherapy for the treatment of LUTS/BPH. Systematic review and meta-analysis of randomized and observational studies in patients with LUTS/BPH identified through searches in Medline, Web of Knowledge [ISI], Scopus, the Cochrane Library, and bibliographic references up to March 2017. Articles studying S. repens extracts other than Permixon were excluded. Data was collected on IPSS score, peak urinary flow (Qmax), nocturia, quality of life, prostate volume, sexual function, and adverse drug reactions (ADR). Data obtained from randomized controlled trials (RCT) and observational studies (OS) were analysed jointly and separately using a random effects model. A sub-group analysis was performed of studies which included patients on longer-term treatment (≥one year). Data from 27 studies (15 RCTs and 12 OS) were included for meta-analysis (total N=5,800). Compared with placebo, the HESr was associated with 0.64 (95% CI -0.98 to -0.31) fewer voids per night (p=0.0001) and an additional mean increase in Qmax of 2.75 mL/s (95% CI 0.57 to 4.93; p=0.01). When compared with alpha-blockers, the HESr showed similar improvements on IPSS (WMD 0.57; 95%CI, -0.27 to 1.42; p=0.18) and a comparable increase in Qmax to tamsulosin (WMD -0.02; 95%CI, -0.71 to 0.66; p=0.95). Efficacy assessed using the IPSS was similar after 6 months of treatment between the HESr and 5ARIs. Analysis of all available published data for the HESr showed a mean improvement in IPSS score from baseline of -5.73 points (95% CI -6.91 to -4.54; p<0.0001). HESr did not negatively affect sexual function and no clinically relevant effect was observed on PSA. Prostate volume decreased slightly. Similar efficacy results were observed in patients treated for ≥1 year (n=447). The HESr had a favourable safety profile, with gastrointestinal disorders being the most frequent ADR (mean incidence of 3.8%). The present meta-analysis, which includes all available RCTs and OS, shows that the HESr (Permixon) reduced nocturia and improved Qmax compared with placebo and had a similar efficacy to tamsulosin and short-term 5-ARI in relieving LUTS. HESr (Permixon) appears to be an efficacious and well-tolerated therapeutic option for the long-term medical treatment of LUTS/BPH. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  9. Comparison of Vela and holmium laser enucleation of the prostate: a retrospective clinical trial with a 12-month follow-up.

    PubMed

    Gu, Meng; Liu, Chong; Chen, Yan-Bo; Xu, Huan; Fu, Shi; Chen, Qi; Wang, Zhong

    2018-05-01

    This study aimed to estimate the validity and applicability of Vela laser enucleation of the prostate (VoLEP) in the management of benign prostatic hyperplasia (BPH). A retrospective chart review of 112 patients with BPH who underwent VoLEP (n = 60) or holmium laser enucleation of the prostate (HoLEP) (n = 56) was conducted at our institution from January 2015 to June 2015. The general and perioperative characteristics of the patients were collected. The 12-month follow-up data, including the lower urinary tract symptom (LUTS) indexes (International Prostate Symptom Score [I-PSS], quality-of-life [QoL] score and maximum flow rate [Qmax]), as well as rates of perioperative and late complications, were analyzed. No significant differences were observed in pre- and perioperative parameters, including operation time (58.05 ± 10.14 vs. 60.14 ± 12.30 min, P = 0.44), serum sodium decrease (3.49 ± 0.83 vs. 3.48 ± 0.84 mmol/L, P = 0.97), hemoglobin decrease (1.28 ± 0.38 vs. 1.24 ± 0.77 g/dL, P = 0.71), catheterization time (3.63 ± 1.10 vs. 3.89 ± 1.11 days, P = 0.21) and hospital stay (4.57 ± 1.25 vs. 4.68 ± 1.18 days, P = 0.63) between the two groups of patients. Compared with the HoLEP group, the noise during operation was lower in VoLEP group (47.22 ± 10.31 vs. 59.45 ± 9.65 db, P < 0.05). During 1, 6 and 12 months of follow-up visits, the LUTS indexes (I-PSS, QoL score and Qmax) were remarkably improved in both groups when comparing with the baseline values. Furthermore, LUTS indexes were comparable in both groups (P > 0.05). Similarly as the holmium laser, the Vela laser is a potent, safe, efficient durable and surgical treatment option for minimally invasive surgery in patients with BPH-induced LUTS.

  10. The effects of tetracaine on charge movement in fast twitch rat skeletal muscle fibres.

    PubMed

    Hollingworth, S; Marshall, M W; Robson, E

    1990-02-01

    1. The effects of tetracaine, a local anaesthetic that inhibits muscle contraction, on membrane potential and intramembrane charge movements were investigated in fast twitch rat muscle fibres (extensor digitorum longus). 2. The resting membrane potentials of surface fibres from muscles bathed in isotonic Ringer solution containing 2 mM-tetracaine were well maintained, but higher concentrations of tetracaine caused a time-dependent fall of potential. Muscle fibres bathed in hypertonic solutions containing 2 mM-tetracaine were rapidly depolarized. In both isotonic and hypertonic solutions, the depolarizing effect of tetracaine could not be reversed. 3. Charge movement measurements were made using the middle-of-the-fibre voltage clamp technique. The voltage dependence of charge movements measured in cold isotonic solutions was well fitted by a Boltzmann distribution (Q(V) = Qmax/(1 + exp(-(V-V)/k] where Qmax = 37.3 +/- 2.8 nC muF-1, V = -17.9 +/- 1.2 mV and k = 12.6 +/- 0.8 mV (n = 6, 2 degrees C; means +/- S.E. of means). Similar values were obtained when 2 mM-tetracaine was added to the isotonic bathing fluid (Qmax = 40.6 +/- 2.3 nC microF-1, V = -14.1 +/- 1.3 mV, k = 15.3 +/- 0.8 mV; n = 8, 2 degrees C). 4. Charge movements measured around mechanical threshold in muscle fibres bathed in hypertonic solutions were reduced when 2 mM-tetracaine was added to the bathing fluid. The tetracaine-sensitive component of charge was well fitted with an unconstrained Boltzmann distribution which gave: Qmax = 7.5 nC microF-1, V = -46.5 mV, k = 5.5 mV. The e-fold rise of the foot of the curve was 9.3 mV.

  11. The effects of tetracaine on charge movement in fast twitch rat skeletal muscle fibres.

    PubMed Central

    Hollingworth, S; Marshall, M W; Robson, E

    1990-01-01

    1. The effects of tetracaine, a local anaesthetic that inhibits muscle contraction, on membrane potential and intramembrane charge movements were investigated in fast twitch rat muscle fibres (extensor digitorum longus). 2. The resting membrane potentials of surface fibres from muscles bathed in isotonic Ringer solution containing 2 mM-tetracaine were well maintained, but higher concentrations of tetracaine caused a time-dependent fall of potential. Muscle fibres bathed in hypertonic solutions containing 2 mM-tetracaine were rapidly depolarized. In both isotonic and hypertonic solutions, the depolarizing effect of tetracaine could not be reversed. 3. Charge movement measurements were made using the middle-of-the-fibre voltage clamp technique. The voltage dependence of charge movements measured in cold isotonic solutions was well fitted by a Boltzmann distribution (Q(V) = Qmax/(1 + exp(-(V-V)/k] where Qmax = 37.3 +/- 2.8 nC muF-1, V = -17.9 +/- 1.2 mV and k = 12.6 +/- 0.8 mV (n = 6, 2 degrees C; means +/- S.E. of means). Similar values were obtained when 2 mM-tetracaine was added to the isotonic bathing fluid (Qmax = 40.6 +/- 2.3 nC microF-1, V = -14.1 +/- 1.3 mV, k = 15.3 +/- 0.8 mV; n = 8, 2 degrees C). 4. Charge movements measured around mechanical threshold in muscle fibres bathed in hypertonic solutions were reduced when 2 mM-tetracaine was added to the bathing fluid. The tetracaine-sensitive component of charge was well fitted with an unconstrained Boltzmann distribution which gave: Qmax = 7.5 nC microF-1, V = -46.5 mV, k = 5.5 mV. The e-fold rise of the foot of the curve was 9.3 mV. PMID:2348406

  12. The role of counter ions in nano-hematite synthesis: Implications for surface area and selenium adsorption capacity.

    PubMed

    Lounsbury, Amanda W; Yamani, Jamila S; Johnston, Chad P; Larese-Casanova, Philip; Zimmerman, Julie B

    2016-06-05

    Nano metal oxides are of interest for aqueous selenium (Se) remediation, and as such, nano-hematite (nα-Fe2O3) was examined for use as a Se adsorbent. The effect of surface area on adsorption was also studied. nα-Fe2O3 particles were synthesized from Fe(NO3)3 and FeCl3 via forced hydrolysis. The resulting particles have similar sizes, morphologies, aggregate size, pore size, and PZC. The nα-Fe2O3 from FeCl3 (nα-Fe2O3-C) differs from the nα-Fe2O3 from Fe(NO3)3 (nα-Fe2O3-N) with a ∼25±2m(2)/g greater surface area. Selenite Se(IV) adsorption capacity on nα-Fe2O3 has a qmax ∼17mg/g for the freeze-dried and re-suspended nα-Fe2O3. The Δqmax for nα-Fe2O3 from Fe(NO3)3 and FeCl3 that remained in suspension was 4.6mg/g. For selenate Se(VI), the freeze-dried and re-suspended particles realize a Δqmax= 1.5mg/g for nα-Fe2O3 from Fe(NO3)3 and FeCl3. The nα-Fe2O3 from Fe(NO3)3 and FeCl3 that remained in suspension demonstrated Se(VI) Δqmax=5.4mg/g. In situ ATR-FTIR isotherm measurements completed for Se(VI) at a pH 6 suggest that Se(VI) forms primarily outer-sphere complexes with nα-Fe2O3 synthesized from both salts. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Selective Sorption of Dissolved Organic Carbon Compounds by Temperate Soils

    PubMed Central

    Jagadamma, Sindhu; Mayes, Melanie A.; Phillips, Jana R.

    2012-01-01

    Background Physico-chemical sorption onto soil minerals is one of the major processes of dissolved organic carbon (OC) stabilization in deeper soils. The interaction of DOC on soil solids is related to the reactivity of soil minerals, the chemistry of sorbate functional groups, and the stability of sorbate to microbial degradation. This study was conducted to examine the sorption of diverse OC compounds (D-glucose, L-alanine, oxalic acid, salicylic acid, and sinapyl alcohol) on temperate climate soil orders (Mollisols, Ultisols and Alfisols). Methodology Equilibrium batch experiments were conducted using 0–100 mg C L−1 at a solid-solution ratio of 1∶60 for 48 hrs on natural soils and on soils sterilized by γ-irradiation. The maximum sorption capacity, Qmax and binding coefficient, k were calculated by fitting to the Langmuir model. Results Ultisols appeared to sorb more glucose, alanine, and salicylic acid than did Alfisols or Mollisols and the isotherms followed a non-linear pattern (higher k). Sterile experiments revealed that glucose and alanine were both readily degraded and/or incorporated into microbial biomass because the observed Qmax under sterile conditions decreased by 22–46% for glucose and 17–77% for alanine as compared to non-sterile conditions. Mollisols, in contrast, more readily reacted with oxalic acid (Qmax of 886 mg kg−1) and sinapyl alcohol (Qmax of 2031 mg kg−1), and no degradation was observed. The reactivity of Alfisols to DOC was intermediate to that of Ultisols and Mollisols, and degradation followed similar patterns as for Ultisols. Conclusion This study demonstrated that three common temperate soil orders experienced differential sorption and degradation of simple OC compounds, indicating that sorbate chemistry plays a significant role in the sorptive stabilization of DOC. PMID:23209742

  14. Kinetic modeling and thermodynamic study to remove Pb(II), Cd(II), Ni(II) and Zn(II) from aqueous solution using dead and living Azolla filiculoides.

    PubMed

    Rakhshaee, Roohan; Khosravi, Morteza; Ganji, Masoud Taghi

    2006-06-30

    Dead Azolla filiculoides can remove Pb(2+),Cd(2+), Ni(2+) and Zn(2+) corresponding to second-order kinetic model. The maximum adsorption capacity (Q(max)) to remove these metal ions by the alkali and CaCl(2)/MgCl(2)/NaCl (2:1:1, molar ratio) activated Azolla from 283 to 313K was 1.431-1.272, 1.173-0.990, 1.365-1.198 and 1.291-0.981mmol/g dry biomass, respectively. Q(max) to remove these heavy metals by the non-activated Azolla at the mentioned temperature range was obtained 1.131-0.977, 1.092-0.921, 1.212-0.931 and 1.103-0.923mmol/g dry biomass, respectively. In order to remove these metal ions by the activated Azolla, the enthalpy change (DeltaH) was -4.403, -4.495, -4.557 and -4.365kcal/mol and the entropy change (DeltaS) was 2.290, 1.268, 1.745 and 1.006cal/molK, respectively. While, to remove these metal ions by the non-activated Azolla, DeltaH was -3.685, -3.766, -3.967 and -3.731kcal/mol and DeltaS was 2.440, 1.265, 1.036 and 0.933cal/molK, respectively. On the other hand, the living Azolla removed these heavy metals corresponding to first-order kinetic model. It was also shown that pH, temperature and photoperiod were effective both on the rate of Azolla growth and the rate of heavy metals uptake during 10 days. It was appeared the use of Ca(NO(3))(2) increased both Azolla growth rate and the rate of heavy metals uptake while the using KNO(3) although increased Azolla growth rate but decreased the rate of heavy metals uptake.

  15. The role of chitosan as nanofiller of graphite oxide for the removal of toxic mercury ions.

    PubMed

    Kyzas, George Z; Travlou, Nikolina A; Deliyanni, Eleni A

    2014-01-01

    The present study focuses on the role of chitosan (CS) as nanofiller of graphite oxide (GO) in order to prepare composite materials with improved Hg(II) adsorption properties. The removal of Hg(II) from aqueous solutions was studied using adsorbents as graphite oxide (GO), graphite oxide nanofilled with chitosan (GO/CS) and magnetic chitosan (GO/mCS). Many possible interactions between materials and Hg(II) were observed after adsorption and explained via characterization with various techniques (SEM/EDAX, FTIR, XRD, DTG). The adsorption evaluation was done studying various parameters as the effect of pH (both in adsorption and desorption), contact time (pseudo-second order fitting), temperature (isotherms at 25, 45, 65 °C), in line with a brief thermodynamic analysis (ΔG(0), ΔH(0), ΔS(0)). The maximum adsorption capacity (fitting with Langmuir model) of GO at 25 °C was Qmax=187 mg/g, while after the CS nanofilling (formation of the composite GO/CS), Qmax was increased to 381 mg/g with a further enhancement for GO/mCS (Qmax=397 mg/g). Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Transvesical robotic simple prostatectomy: initial clinical experience.

    PubMed

    Leslie, Scott; Abreu, Andre Luis de Castro; Chopra, Sameer; Ramos, Patrick; Park, Daniel; Berger, Andre K; Desai, Mihir M; Gill, Inderbir S; Aron, Monish

    2014-08-01

    Despite significant developments in transurethral surgery for benign prostatic hyperplasia (BPH), simple prostatectomy remains an excellent option for patients with large glands. To describe our technique of transvesical robotic simple prostatectomy (RSP). From May 2011 to April 2013, 25 patients underwent RSP. We performed RSP using our technique. Baseline demographics, pathology data, perioperative complications, 90-d complications, and functional outcomes were assessed. Mean patient age was 72.9 yr (range: 54-88), baseline International Prostate Symptom Score (IPSS) was 23.9 (range: 9-35), prostate volume was 149.6 ml (range: 91-260), postvoid residual (PVR) was 208.1 ml (range: 72-800), maximum flow rate (Qmax) was 11.3 ml/s, and preoperative prostate-specific antigen was 9.4 ng/ml (range: 1.9-56.3). Eight patients were catheter dependent before surgery. Mean operative time was 214 min (range: 165-345), estimated blood loss was 143 ml (range: 50-350), and the hospital stay was 4 d (range: 2-8). There were no intraoperative complications and no conversions to open surgery. Five patients had a concomitant robotic procedure performed. Early functional outcomes demonstrated significant improvement from baseline with an 85% reduction in mean IPSS (p<0.0001), an 82.2% reduction in mean PVR (p=0.014), and a 77% increase in mean Qmax (p=0.20). This study is limited by small sample size and short follow-up period. One patient had a urinary tract infection; two had recurrent hematuria, one requiring transfusion; one patient had clot retention and extravasation, requiring reoperation. Our technique of RSP is safe and effective. Good functional outcomes suggest it is a viable option for BPH and larger glands and can be used for patients requiring concomitant procedures. We describe the technique and report the initial results of a series of cases of transvesical robotic simple prostatectomy. The procedure is both feasible and safe and a good option for benign prostatic hyperplasia with larger glands. Copyright © 2013 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  17. [Safety and effect of transurethral holmium laser enucleation of the prostate versus bipolar transurethral plasmakinetic prostatectomy for benign prostatic hyperplasia: A meta-analysis].

    PubMed

    Guo, Qiang; Xiao, Yi; Li, Jian-Wen; Zhang, Jian-Dong; Zhang, Yan-Gang

    2016-10-01

    To evaluate the safety and effect of transurethral holmium laser enucleation of the prostate (HoLEP) in comparison with bipolar transurethral plasmakinetic prostatectomy (TUPKP) in the treatment of benign prostatic hyperplasia (BPH). We searched the databases of PubMed, SCI, Ovid, The Cochrane Library, CNKI, CBM, VIP, and Wangfang Data for controlled clinical trials about HoLEP versus TUPKP in the treatment of BPH published up to April 2016. The studies were screened according to the inclusion and exclusion criteria, the data extracted, and their quality evaluated by 2 reviewers independently, followed by a meta-analysis using the RevMan 5.3 software. A total of 7 studies were included, involving 2031 cases. In comparison with TUPKP, HoLEP showed significantly longer operation time (WMD = 24.61, 95% CI 11.88, 37.34, P lt; 0.001), shorter hospital stay (WMD =-1.91, 95% CI -3.74, -0.07, P = 0.04), shorter bladder irrigation time (WMD = -21.50, 95% CI -34.95, -8.06, P = 0.002), shorter catheter-indwelling time (WMD = -27.60, 95% CI -48.17, -7.03, P = 0.009), less hemoglobin loss (WMD = - 0.42, 95% CI -0.78, -0.07, P = 0.02); lower postvoid residual urine (PVR) at 3 months (WMD = -3.35, 95% CI -4.46, -2.23, P<0.001) and 6 months after surgery (WMD =-1.11, 95% CI -2.18, -0.05, P = 0.04); higher maximum urinary flow rate (Qmax) (WMD = 0.42, 95% CI 0.04, 0.80, P = 0.03) and fewer urinary tract irritation symptoms (OR =0.58, 95% CI 0.41, 0.81, P = 0.002) at 12 months after surgery. No statistically significant differences were found between the two groups in the volume of resected tissue, serum sodium reduction, urethral stricture, erectile dysfunction, retrograde ejaculation, or transient urinary incontinence (P>0.05), or in the improvement of the quality of life (QoL) at 1, 3 and 12 months, International Prostate Symptom Score (IPSS) at 1, 3, 6 and 12 months, Qmax at 1, 3 and 6 months, or International Index of Erectile Function-5 (IIEF-5) at 6 months after surgery (P>0.05). HoLEP is preferred to TUPKP in clinical application for its advantages of higher Qmax at 12 months after surgery, lower PVR at 3 and 6 months, higher peri-operative safety, faster recovery, and fewer urinary tract irritation symptoms. However, for the quantity and quality limitations of the included publications, our findings are to be further supported by large-sample, multi-center, and high-quality prospective controlled clinical studies.

  18. Aquablation - image-guided robot-assisted waterjet ablation of the prostate: initial clinical experience.

    PubMed

    Gilling, Peter; Reuther, Rana; Kahokehr, Arman; Fraundorfer, Mark

    2016-06-01

    To assess the safety and feasibility of aquablation in a first-in-man study. Aquablation is a novel minimally invasive water ablation therapy combining image guidance and robotics (AquaBeam(®) ) for the targeted and heat-free removal of prostatic tissue in men with lower urinary tract symptoms (LUTS) secondary to benign prostatic hyperplasia (BPH). A prospective, non-randomised, single-centre trial in men aged 50-80 years with moderate-to-severe LUTS was conducted. Under real-time image-based ultrasonic guidance, AquaBeam technology enables surgical planning and mapping, and leads to a controlled heat-free resection of the prostate using a high-velocity saline stream. Patients were evaluated at 1, 3, and 6 months after aquablation. In all, 15 patients were treated with aquablation under general anaesthesia. The mean (range) age was 73 (59-86) years and prostate size was 54 (27-85) mL. A substantial median lobe was present in six of the 15 patients. The mean International Prostate Symptom Score (IPSS) was 23 and the maximum urinary flow rate (Qmax ) was 8.4 mL/s at baseline. The mean procedural time was 48 min with a mean aquablation treatment time of 8 min. All procedures were technically successful with no serious or unexpected adverse events (AEs). All but one patient had removal of catheter on day 1, and most of the patients were discharged on the first postoperative day. No patient required a blood transfusion, and postoperative sodium changes were negligible. There were no serious 30-day AEs. One patient underwent a second aquablation treatment within 90 days of the first procedure. The mean IPSS score statistically improved from 23.1 at baseline to 8.6 at 6 months (P < 0.001) and the Qmax increased from 8.6 mL/s at baseline to 18.6 mL/s at the 6-month follow-up (P < 0.001). At 6 months, the mean detrusor pressure at Qmax decreased to 45 cmH2 0 from 66 cmH2 0 at baseline (P < 0.05), and the mean prostate size was reduced to 36 mL, a 31% reduction in size vs baseline (P < 0.001). No cases of urinary incontinence or erectile dysfunction were reported. These preliminary results from this initial study show aquablation of the prostate is technically feasible with a safety profile comparable to other BPH technologies. The combination of surgical mapping by the operating surgeon and the high-velocity saline provides a promising technique delivering a conformal, quantifiable, and standardised heat-free ablation of the prostate. Advantages of this technique include reduction in resection time compared with other endoscopic methods, as well as the potential to preserve sexual function. © 2015 The Authors BJU International © 2015 BJU International Published by John Wiley & Sons Ltd.

  19. Convective Radiofrequency Water Vapor Thermal Therapy with Rezūm System.

    PubMed

    Helo, Sevann; Holland, Bradley; McVary, Kevin T

    2017-10-01

    Lower urinary tract symptoms (LUTS) secondary to benign prostatic hyperplasia (BPH) are amongst the most commonly treated conditions by urologists. Minimally invasive therapies for the treatment of BPH/LUTS have garnered increased interest as new technology has emerged, improving durability, efficacy, and safety. This paper reviews the most recent literature regarding water vapor therapy, a convective thermal therapy that ablates prostatic tissue. The current literature includes a pilot study of 65 men and a randomized controlled trial (RCT) of 197 men investigating the efficacy and safety profile of water vapor therapy up to 2 years. Subjects treated with water vapor therapy demonstrated a 51% reduction in IPSS from baseline, sustained at 24 months (p < 0.0001). Durable improvements in max flow rate (Qmax) and quality of life (QoL) were also achieved, while no changes in sexual function were observed. Reporting of adverse events (AEs) reveals predominantly Clavien grade I complications that were self-limited. The clinical efficacy and safety of water vapor therapy are durable to 24 months making it an attractive alternative for patients seeking a minimally invasive treatment for LUTS due to BPH.

  20. Two-year results after convective radiofrequency water vapor thermal therapy of symptomatic benign prostatic hyperplasia

    PubMed Central

    Dixon, Christopher M; Cedano, Edwin Rijo; Pacik, Dalibor; Vit, Vítězslav; Varga, Gabriel; Wagrell, Lennart; Larson, Thayne R; Mynderse, Lance A

    2016-01-01

    Objective The objective of this study was to assess the effectiveness and safety of convective radiofrequency (RF) water vapor thermal therapy in men with lower urinary tract symptoms (LUTS) associated with benign prostatic hyperplasia (BPH); a pilot study design with 2-year follow-up evaluations. Patients and methods Men aged ≥45 years with an International Prostate Symptom Score ≥13, a maximum urinary flow rate (Qmax) ≤15 mL/s, and prostate volume 20–120 cc were enrolled in a prospective, open-label pilot study using convective RF water vapor energy with the Rezūm System. Patients were followed up for 2 years after transurethral thermal treatment at 3 international centers in the Dominican Republic, Czech Republic, and Sweden. The transurethral thermal therapy utilizes radiofrequency to generate wet thermal energy in the form of water vapor injected through a rigid endoscope into the lateral lobes and median lobe as needed. Urinary symptom relief, urinary flow, quality of life (QOL) impact, sexual function, and adverse events (AEs) were assessed at 1 week, 1, 3, 6, 12, and 24 months. Results LUTS, flow rate, and QOL showed significant improvements from baseline; prostate volumes were appreciably reduced. Sexual function was maintained and no de novo erectile dysfunction occurred. The responses evident as early as 1 month after treatment remained consistent and durable over the 24 months of study. Early AEs were typically transient and mild to moderate; most were related to endoscopic instrumentation. No procedure related to late AEs were seen. Conclusion The Rezūm System convective RF thermal therapy is a minimally invasive treatment for BPH/LUTS which can be performed in the office or as an outpatient procedure with minimal associated perioperative AEs. It has no discernable effect on sexual function and provides significant improvement of LUTS that remain durable at 2 years. PMID:27921028

  1. [Perineal urethrostomy plus secondary urethroplasty for ultralong urethral stricture: clinical outcomes and influence on the patient's quality of life].

    PubMed

    Wang, Yong-Quan; Zhang, Heng; Shen, Wen-Hao; Li, Long-Kun; Li, Wei-Bing; Xiong, En-Qing

    2012-04-01

    To investigate the outcomes of perineal urethrostomy plus secondary urethroplasty for ultralong urethral stricture and assess its influence on the patient's quality of life. We retrospectively analyzed 54 cases of ultralong urethral stricture treated by perineal urethrostomy from 2000 to 2010. The mean age of the patients was 40 years, and the average length of stricture was 6.5 cm. We evaluated the patients'quality of life by questionnaire investigation and the clinical outcomes based on IPSS, Qmax, the necessity of urethral dilation and satisfaction of the patients. The mean Qmax of the 54 patients was (14.0 +/- 4.7) ml/min. Of the 34 cases that underwent secondary urethroplasty, 22 (64.7%) achieved a mean Qmax of (12.0 +/- 3.5) ml/min, 8 (23.5%) needed regular urethral dilatation and 4 (11.8%) received internal urethrotomy because of restenosis. IPSS scores were 5.4 +/- 2.1 and 8.5 +/- 5.8 after perineal urethrostomy and secondary urethroplasty, respectively. Fifty of the total number of patients (92.6%) were satisfied with the results of perineal urethrostomy, and 22 of the 34 (64.7%) with the results of secondary urethroplasty. Perineal urethrostomy plus secondary urethroplasty is safe and effective for ultralong urethral stricture, and affects very little the patient's quality of life.

  2. Phosphorus fraction and phosphate sorption-release characteristics of the wetland sediments in the Yellow River Delta

    NASA Astrophysics Data System (ADS)

    Cui, Yuan; Xiao, Rong; Xie, Ying; Zhang, Mingxiang

    2018-02-01

    The aim of this study was to investigate phosphorus (P) fractions and phosphate sorption-release characteristics of the surface sediments regarding the wetland restoration in the Yellow River Delta (YRD). Sediments samples were collected from three typical sample plots: Phragmites australis community (p), Suaeda salsa community (s), and bare land (b) both in natural wetland (N) and restored wetland (R). The results showed that the mean content of TP was 541.58 mg/kg, and the rank order of P fractions were: inorganic phosphorus (IP) (65.6%) > residual phosphorus (RP) (24.9%) > organic phosphorus (OP) (9.5%). For sediments under the same land cover, TP and OP contents were significantly higher in natural wetlands than those in restored wetlands. This indicated that the restoration project really made a difference in TP content of sediments, and the decreased TP might result from decreased OP. For P kinetics sorption, a quick sorption mainly occurred within 0.5 h. The maximum phosphorus adsorption capacities (Qmax) ranging from 139.40 mg/kg to 224.06 mg/kg and the bonding energy constant (K) ranging from 0.33 mg/L to 1.37 mg/L were both obtained using a Langmuir model. In addition, Qmax, P release (Pr) and P release rates (Prr) were in the order of Nb > Np > Ns > Rb > Rp > Rs, Np > Rp > Ns > Rs = Nb > Rb and Rp > Ns > Rs > Rb > Np > Nb, respectively. This indicated that sediments from natural wetland could adsorb more P as well as release more P into overlying water, moreover, more content of P were left in sediments comparing to restored wetland. Sediments from bare land were more likely to retain P as a pool because of the highest sorption capacity while lowest release potential. Our study showed that P sorption-release and the quick sorption processes were mainly affected by sediment moisture, amorphous iron and aluminum oxides (Feox and Alox). Besides, Qmax was related to background value of sediments P. OP was the major P fraction adsorbed by sediments, and the P adsorbed by sediments was mainly adsorbed on Feox and Alox.

  3. A comparative study of thulium laser resection of the prostate and bipolar transurethral plasmakinetic prostatectomy for treating benign prostatic hyperplasia.

    PubMed

    Peng, Bo; Wang, Guang-chun; Zheng, Jun-hua; Xia, Sheng-qiang; Geng, Jiang; Che, Jian-ping; Yan, Yang; Huang, Jian-hua; Xu, Yun-fei; Yang, Bin

    2013-04-01

    WHAT'S KNOWN ON THE SUBJECT? AND WHAT DOES THE STUDY ADD?: Thulium laser is a new generation of surgical laser. It is a minimally invasive technology with several advantages, including rapid vaporization and minimal tissue damage and bleeding. However, details regarding the safety and efficacy of thulium laser in treating BPH remains unknown. We performed a comparative study in 100 patients with BPH of the safety and efficacy of thulium laser resection of the prostate (TMLRP, n = 50) and bipolar transurethral plasmakinetic prostatectomy (TUPKP, n = 50). We found that the efficacy and indications were the same in TMLRP and TUPKP. In TUPKP, the morbidity of urethrostenosis was low, and was nearly bloodless in surgery and had higher safety. Nevertheless, TUPKP is more suitable for patients with larger prostate volume. To compare the safety and short-term efficacy of thulium laser resection of the prostate (TMLRP) and bipolar transurethral plasmakinetic prostatectomy (TUPKP) for the treatment of patients with benign prostatic hyperplasia (BPH). A total of 100 patients diagnosed with BPH were randomly divided into two groups, treated with either TMLRP (50, group 1) or TUPKP (50, group 2). There was no significant difference in preoperative variables such as age, prostate volume, prostate-specific antigen (PSA) level, International Prostate Symptom Score (IPSS), maximum urinary flow rate (Qmax ) and postvoid residual urine volume (PVR) between the two groups. The perioperative parameters and therapeutic effects were recorded and compared between the two groups. There were significant differences in the following parameters between the two groups (TMLRP vs TUPKP [mean ± SD]): operation duration, 61.2 ± 24.2 vs 30.14 ± 15.9 min; catheterization time, 1.8 ± 0.4 vs 3.2 ± 0.6 d; postoperative hospital stay, 3.3 ± 0.8 vs 4.1 ± 1.3 d. The volume of blood loss and postoperative bladder irrigation were significantly lower in TMLRP group than in the TUPKP group. At 1 month after the operation, there were four cases of urethral stricture in the TUPKP group. At 3 months after the operation, IPSS, quality of life (QoL), Qmax and PVR were significantly improved, with no significant difference between the two groups. TMLRP is superior to TUPKP in terms of safety, blood loss, recovery time and complication rate, and is as efficacious as TUPKP for treating BPH. Operation duration was significantly longer in the TMLRP group than in the TUPKP group. © 2012 BJU International.

  4. Bladder outlet obstruction in women: definition and characteristics.

    PubMed

    Groutz, A; Blaivas, J G; Chaikin, D C

    2000-01-01

    The prevalence of bladder outlet obstruction in women is unknown and most probably has been underestimated. Moreover, there are no standard definitions for the diagnosis of bladder outlet obstruction in women. Our study was conducted to define as well as to examine the clinical and urodynamic characteristics of bladder outlet obstruction among women referred for evaluation of voiding symptoms. Bladder outlet obstruction was defined as a persistent, low, maximum "free" flow rate of <12 mL/s in repeated non-invasive uroflow studies, combined with high detrusor pressure at a maximum flow (p(det.Q)(max) >20 cm H(2)O) during detrusor pressure-uroflow studies. A urodynamic database of 587 consecutive women identified 38 (6.5%) women with bladder outlet obstruction. The mean age of the patients was 63.9 +/- 17.5 years. The mean maximum "free" flow, voided volume, and residual urinary volume were 9.4 +/-3.9 mL/s, 144. 9 +/- 72.7 mL, and 86.1 +/- 98.8 mL, respectively. The mean p(det. Q)(max) was 37.2 +/- 19.2 cm H(2)O. Previous anti-incontinence surgery and severe genital prolapse were the most common etiologies, accounting for half of the cases. Other, less common, etiologies included urethral stricture (13%), primary bladder neck obstruction (8%), learned voiding dysfunction (5%), and detrusor external sphincter dyssynergia (5%). Symptomatology was defined as mixed obstructive and irritative in 63% of the patients, isolated irritative in 29%, and isolated obstructive in other 8%. In conclusion, bladder outlet obstruction in women appears to be more common than was previously recognized, occurring in 6.5% of our patients. Micturition symptoms relevant to bladder outlet obstruction are non-specific, and a full urodynamic evaluation is essential in making the correct diagnosis and formulating a treatment plan.

  5. Bipolar plasma enucleation of the prostate vs open prostatectomy in large benign prostatic hyperplasia cases - a medium term, prospective, randomized comparison.

    PubMed

    Geavlete, Bogdan; Stanescu, Florin; Iacoboaie, Catalin; Geavlete, Petrisor

    2013-05-01

    WHAT'S KNOWN ON THE SUBJECT? AND WHAT DOES THE STUDY ADD?: According to the EAU Guidelines 2012, large size benign prostatic hyperplasia (BPH) cases (>80 mL) continue to have open prostatectomy as the first line treatment alternative, despite the substantial peri-operative morbidity and extended catheterization and convalescence periods related to this undoubtedly invasive approach. During the past two decades, holmium laser enucleation of the prostate was constantly described as a successful choice for this category of patients. According to rather numerous studies, the technique displayed superior results in terms of surgical safety and postoperative recovery compared with the open procedure. On the other hand, the concept of electrosurgical enucleation of the prostate, using either a monopolar or bipolar cutting current, materialized into several technical applications that eventually failed to gain general acknowledgement as reliable alternatives to the BPH transurethral approach. While keeping in mind the already proved advantage of enucleating substantial quantities of BPH tissue, bipolar plasma enucleation of the prostate was introduced as a novel endoscopic approach in cases of large prostates. The present trial represents the first prospective, medium-term, randomized comparison to be published of this innovative technique with standard open prostatectomy. Basically, the premises for a viable alternative relied on the practical advantages provided by the 'button' electrode, mainly the large surface creating the conditions for a fast enucleation process, continuous vaporization and concomitant haemostasis. Eventually, it was concluded that the plasma enucleation procedure distinguished itself as a successful treatment option in large BPH patients, characterized by good surgical efficiency, significantly reduced complications, faster postoperative recovery, similar prostatic tissue ablation capabilities and satisfactory follow-up results compared with the open technique. Most importantly, plasma-button enucleation patients benefited from a similar 12 months' outcome from the perspectives of symptom scores and voiding parameters when drawing a parallel with open surgery results, thus underlining the reliable viability of this type of endoscopic approach. To evaluate the viability of bipolar plasma enucleation of the prostate (BPEP) by comparison with open transvesical prostatectomy (OP) in cases of large prostates with regard to surgical efficacy and peri-operative morbidity. To compare the medium-term follow-up parameters specific for the two methods. A total of 140 benign prostatic hyperplasia (BPH) patients with prostate volume >80 mL, maximum flow rate (Qmax ) <10 mL/s and International Prostate Symptom Score (IPSS) >19 were randomized in the two study arms. All cases were assessed preoperatively and at 1, 3, 6 and 12 months after surgery by IPSS, Qmax , quality of life score (QoL) and post-voiding residual urinary volume (PVR). The prostate volume and prostate specific antigen (PSA) level were measured at 6 and 12 months. The BPEP and OP techniques emphasized similar mean operating durations (91.4 vs 87.5 min) and resected tissue weights (108.3 vs 115.4 g). The postoperative haematuria rate (2.9% vs 12.9%) as well as the mean haemoglobin drop (1.7 vs 3.1 g/dL), catheterization period (1.5 vs 5.8 days) and hospital stay (2.1 vs 6.9 days) were significantly improved for BPEP. Recatheterization for acute urinary retention was more frequent in the OP group (8.6% vs 1.4%), while the rates of early irritative symptoms were similar for BPEP and OP (11.4% vs 7.1%). During the follow-up period, no statistically significant difference was determined in terms of IPSS, Qmax , QoL, PVR, PSA level and postoperative prostate volume between the two series. BPEP represents a promising endoscopic approach in large BPH cases, characterized by good surgical efficiency and similar BPH tissue removal capabilities compared with standard transvesical prostatectomy. BPEP patients benefited from significantly reduced complications, shorter convalescence and satisfactory follow-up symptom scores and voiding parameters. © 2013 BJU International.

  6. Utilization of magnetically responsive cereal by-product for organic dye removal.

    PubMed

    Baldikova, Eva; Politi, Dorothea; Maderova, Zdenka; Pospiskova, Kristyna; Sidiras, Dimitrios; Safarikova, Mirka; Safarik, Ivo

    2016-04-01

    Barley straw, an agricultural by-product, can also serve as a low-cost and relatively efficient adsorbent of various harmful compounds. In this case, adsorption of four water-soluble dyes belonging to different dye classes (specifically Bismarck brown Y, representing the azo group; methylene blue, quinone-imine group; safranin O, safranin group; and crystal violet, triphenylmethane group) on native and citric acid-NaOH-modified barley straw, both in magnetic and non-magnetic versions, was studied. The adsorption was characterized using three adsorption models, namely Langmuir, Freundlich and Sips. To compare the maximum adsorption capacities (qmax), the Langmuir model was employed. The qmax values reached 86.5-124.3 mg of dye per g of native non-magnetic straw and 410.8-520.3 mg of dye per g of magnetic chemically modified straw. Performed characterization studies suggested that the substantial increase in qmax values after chemical modification could be caused by rougher surface of adsorbent (observed by scanning electron microscopy) and by the presence of higher amounts of carboxyl groups (detected by Fourier transform infrared spectroscopy). The adsorption processes followed the pseudo-second-order kinetic model and thermodynamic studies indicated spontaneous and endothermic adsorption. The chemical modification of barley straw led to a significant increase in maximum adsorption capacities for all tested dyes, while magnetic modification substantially facilitated the manipulation with adsorbent. © 2015 Society of Chemical Industry.

  7. The simplest equivalent circuit of a pulsed dielectric barrier discharge and the determination of the gas gap charge transfer

    NASA Astrophysics Data System (ADS)

    Pipa, A. V.; Koskulics, J.; Brandenburg, R.; Hoder, T.

    2012-11-01

    The concept of the simplest equivalent circuit for a dielectric barrier discharge (DBD) is critically reviewed. It is shown that the approach is consistent with experimental data measured either in large-scale sinusoidal-voltage driven or miniature pulse-voltage driven DBDs. An expression for the charge transferred through the gas gap q(t) is obtained with an accurate account for the displacement current and the values of DBD reactor capacitance. This enables (i) the significant reduction of experimental error in the determination of q(t) in pulsed DBDs, (ii) the verification of the classical electrical theory of ozonizers about maximal transferred charge qmax, and (iii) the development of a graphical method for the determination of qmax from charge-voltage characteristics (Q-V plots, often referred as Lissajous figures) measured under pulsed excitation. The method of graphical presentation of qmax is demonstrated with an example of a Q-V plot measured under pulsed excitation. The relations between the discharge current jR(t), the transferred charge q(t), and the measurable parameters are presented in new forms, which enable the qualitative interpretation of the measured current and voltage waveforms without the knowledge about the value of the dielectric barrier capacitance Cd. Whereas for quantitative evaluation of electrical measurements, the accurate estimation of the Cd is important.

  8. Efficacy and safety of the urolift® system for the treatment of benign prostate hyperplasia symptoms: systematic review.

    PubMed

    Sánchez-Gómez, L M; Polo-deSantos, M; Gómez-Sancha, F; Luengo-Matos, S

    2015-06-01

    Interest in having alternatives in the treatment of benign prostate hyperplasia. To assess the efficacy and safety of the Urolift® system for treating the symptoms of benign prostate hyperplasia. Systematic review of the literature through searches on PubMed, Cochrane Library, CRD, Clinical Trials and EuroScan, collecting indicators of efficacy and safety. We included 5 case series and one clinical trial. The patients' mean age ranged from 65-74.3 years, and the mean prostate volume was 41-55cm3. The mean number of Urolif® implants was 3.7-5.5. The maximum follow-up in months was 24, 12 (3 studies) and one (2 studies). Improvements were found in lower urinary tract symptoms, as measured with the International Prostate Symptom Score, Benign Prostatic Hyperplasia Impact Index (BPHII), maximum urinary flow (Qmax) and postvoid residual (PVR) volume. Improvements were in found sexual dysfunction symptoms, as measured with the Sexual Health Inventory for Men (SHIM) and the Male Sexual Health Questionnaire or Ejaculatory Dysfunction (MHSQ-EjD), and in quality of life (QoL). In the clinical trial, the differences were significant for International Prostate Symptom Score, BPHII, Qmax and QoL (p<.05). The adverse effects were mild. Although the quality of evidence is low, Urolift® constitutes a good therapeutic alternative for patients with benign prostate hyperplasia. The short to medium-term results show that the technique contributes to improving lower urinary tract symptoms, with no relevant side effects, does not affect sexual function and improves quality of life. Further research is required, especially on long-term results. Copyright © 2014 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  9. Prospective study comparing laparoscopic and open adenomectomy: Surgical and functional results.

    PubMed

    Garcia-Segui, A; Angulo, J C

    Open adenomectomy (OA) is the surgery of choice for large volume benign prostatic hyperplasia, and laparoscopic adenomectomy (LA) represents a minimally invasive alternative. We present a long-term, prospective study comparing both techniques. The study consecutively included 199 patients with benign prostatic hyperplasia and prostate volumes>80g who were followed for more than 12 months. The patients underwent OA (n=97) or LA (n=102). We recorded and compared demographic and perioperative data, functional results and complications using a descriptive statistical analysis. The mean age was 69.2±7.7 years (range 42-87), and the mean prostate volume (measured by TRUS) was 112.1±32.7mL (range 78-260). There were no baseline differences among the groups in terms of age, ASA scale, prostate volume, PSA levels, Qmax, IPSS, QoL or treatments prior to the surgery. The surgical time (P<.0001) and catheter time (P<.0002) were longer in the LA group. Operative bleeding (P<.0001), transfusion rate (P=.0015) and mean stay (P<.0001) were significantly lower in the LA group. The LA group had a lower rate of complications (P=.04), but there were no significant differences between the groups in terms of major complications (Clavien score≥3) (P=.13) or in the rate of late complications (at one year) (P=.66). There were also no differences between the groups in the functional postoperative results: IPSS (P=.17), QoL (P=.3) and Qmax (P=.17). LA is a reasonable, safe and effective alternative that results in less bleeding, fewer transfusions, shorter hospital stays and lower morbidity than OA. LA has similar functional results to OA, at the expense of longer surgical times and longer catheter times. Copyright © 2016 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  10. High intensity focused ultrasound (HIFU) treatment of BPH: results of a multi-center phase III study

    NASA Astrophysics Data System (ADS)

    Sanghvi, N.; Gardner, T.; Koch, M.; Bihrle, R.; Foster, R.; Resnick, M.; Seftel, A.; Grunberger, I.; Stiedle, C.; Corchan, J.

    2003-04-01

    The five centers phase III trial was to show that HIFU can treat prostate tissue thermally for symptomatic relief of BPH and improve flow rates. At five sites, 68 BPH patients were treated with the Sonablate device (Focus Surgery, Inc. Indianapolis, IN). A urethral Foley catheter was inserted into the urethra to aid in positioning and was kept in-situ during the treatment. A cooling device was used to cool the rectal wall. The patients returned home within a few hours after the procedure. The Foley catheter was kept electively to avoid any incidence of acute urinary retention following the therapy. The catheter was removed after 4-5 days. The average treatment time was 38 minutes. The patients were treated without pain, blood loss or complications. At 90 days post treatment, average Qmax and AUA Symptom Scores improved from 8.7 ml/s to 12.66 ml/s (48%) and 23.06 to 11.62 (52%), respectively. Significant prostate tissue changes took place before and after the treatment. 80% of the patients had cavity formation at the site of treatment at the bladder neck and prostate. Nonsurgical HIFU therapy is safe and effective for providing symptomatic relief of BPH symptoms and the treatment can be performed as an outpatient procedure.

  11. Thulium laser VapoResection of the prostate versus traditional transurethral resection of the prostate or transurethral plasmakinetic resection of prostate for benign prostatic obstruction: a systematic review and meta-analysis.

    PubMed

    Deng, Zheng; Sun, Menghao; Zhu, Yiping; Zhuo, Jian; Zhao, Fujun; Xia, Shujie; Han, Bangmin; Herrmann, Thomas R W

    2018-04-12

    To compare the efficacy and safety of thulium laser VapoResection of the prostate (ThuVaRP) versus standard traditional transurethral resection of the prostate (TURP) or plasmakinetic resection of prostate (PKRP) for benign prostatic obstruction. Systematic searches were performed in the Medline, EMBASE, the Cochrane Library, Web of Science, and CNKI in December 2017. The outcomes of demographic and clinical characteristics, perioperative variables, complications, and postoperative efficacy including International Prostate Symptom Score (IPSS), quality of life (QoL), maximum flow rate (Qmax), and postvoid residual (PVR) were assessed. 16 studies were selected in the meta-analysis including nine randomized controlled trials (RCTs) and seven non-RCTs. Among of them, nine studies compared ThuVaRP with PKRP, while seven studies compared ThuVaRP with TURP. It seemed that ThuVaRP needed longer operation time than TURP (WMD = 6.41, 95% CI 1.38-11.44, p = 0.01) and PKRP (WMD = 10.15, 95% CI 5.20-15.10, p < 0.0001). ThuVaRP was associated with less serum hemoglobin decreased, catheterization time, and the length of hospital stay compared with TURP (WMD = - 0.58, 95% CI - 0.77 to 0.38, p < 0.00001; WMD = - 1.89, 95% CI - 2.67 to 1.11, p < 0.00001; WMD = - 2.25, 95% CI - 2.91 to 1.60, p < 0.00001) and PKRP (WMD = - 0.28, 95% CI - 0.46 to 0.10, p = 0.002; WMD = - 1.88, 95% CI - 2.87 to 0.89, p = 0.0002; WMD = - 2.08, 95% CI - 2.63 to 1.54, p<0.00001). According to our assessment, there was no significantly difference in postoperative efficacy. The pooled data indicated that ThuVaRP had a nearly efficacy to TURP and PKRP based on IPSS, QoL, Qmax, and PVR. Although ThuVaRP was associated with longer operation time, it got distinct superiority on serum hemoglobin decreased, catheterization time, and hospital stay.

  12. Augmentation enterocystoplasty is effective in relieving refractory ketamine-related bladder pain.

    PubMed

    Chung, Shiu-Dong; Wang, Chung-Cheng; Kuo, Hann-Chorng

    2014-11-01

    To report our early results of augmentation enterocystoplasty (AE) for severe bladder pain associated with chronic ketamine cystitis (KC). We performed AE for 14 patients with refractory KC-related bladder pain, which is based on the criteria including severe bladder pain, urgency and frequency and/or upper urinary tract damage such as bilateral hydronephrosis, and contracted bladder. Every patient had been treated conservatively with medication or cystoscopic hydrodistention for at least 1 year before they had received surgical intervention. Video-urodynamic studies were obtained before AE and 3-6 months after surgery. Outcome measurements included visual analogue score (VAS) for pain, cystometric bladder capacity (CBC), maximum urinary flow rate (Qmax), post-void residual, and maximal detrusor pressure (Pdet). The patients' general satisfaction with regard to treatment outcome was also assessed by the Patient Perception of Bladder Condition (PPBC). A total of 4 men and 10 women underwent this procedure as indicated. The mean age was 26.7 (ranged 20-38) years old and the duration of ketamine abuse was 3.82 years (ranged 2-7). Contracted bladder was noted in all patients, hydronephrosis in nine and vesicoureteral reflux (VUR) in eight. At 3-6 months after AE, VAS was remarkably improved from baseline to the end-point (8.29 ± 1.54 vs. 2.14 ± 1.51, P < 0.0001), CBC increased from 50.9 ± 15.7 to 309.2 ± 58.0 ml (P < 0.0001), Qmax increased from 6.94 ± 3.60 to 15.2 ± 5.51 ml/sec (P < 0.0001) and Pdet reduced from 29.7 ± 16.0 to 17.9 ± 8.2 cmH2 O (P = 0.008). All patients reported marked improvement in PPBC from 6.0 to 1.4 ± 0.89 (P < 0.0001). All hydronephrosis disappeared and VUR was resolved in five patients after AE with ureteral reimplantation. This pilot study demonstrated that AE is effective in relieving refractory ketamine-related bladder pain and lower urinary tract symptoms. © 2013 Wiley Periodicals, Inc.

  13. Treatment for long bulbar urethral strictures with membranous involvement using urethroplasty with oral mucosa graft.

    PubMed

    Gimbernat, H; Arance, I; Redondo, C; Meilán, E; Andrés, G; Angulo, J C

    2014-10-01

    Urethroplasty with oral mucosa grafting is the most popular technique for treating nontraumatic bulbar urethral strictures; however, cases involving the membranous portion are usually treated using progressive perineal anastomotic urethroplasty. We assessed the feasibility of performing dorsal (or ventral) graft urethroplasty on bulbar urethral strictures with mainly membranous involvement using a modified Barbagli technique. This was a prospective study of 14 patients with bulbomembranous urethral strictures who underwent dilation urethroplasty with oral mucosa graft between 2005 and 2013, performed using a modified technique Barbagli, with proximal anchoring of the graft and securing of the graft to the tunica cavernosa in 12 cases (85.7%) and ventrally in 2 (14.3%). The minimum follow-up time was 1 year. We evaluated the subjective (patient satisfaction) and objective (maximum flow [Qmax] and postvoid residual volume [PVRV], preoperative and postoperative) results and complications. Failure was defined as the need for any postoperative instrumentation. A total of 14 patients (median age, 64+13 years) underwent surgery. The main antecedent of note was transurethral resection of the prostate in 9 cases (64.3%). The median length of the stenosis was 45+26.5mm. Prior to surgery, 50% of the patients had been subjected to dilatations and 4% to endoscopic urethrotomy. The mean surgical time and hospital stay were was 177+76min and 1.5+1 day, respectively. The preoperative Qmax and PVRV values were 4.5+4.45mL/sec and 212.5+130 cc, respectively. The postoperative values were 15.15+7.2mL/sec and 6+21.5cc, respectively (P<.01 for both comparisons). Surgery was successful in 13 cases (92.9%). None of the patients had major complications. There were minor complications in 1 (7.1%) patient, but reintervention was no required. The repair of long bulbar urethral strictures with membranous involvement using urethroplasty with free oral mucosa grafts represents a viable alternative for patients with nontraumatic etiology and little fibrosis. The dilation of the urethral lumen achieves good results with minimum failure rates and little probability of complications. For many of these patients, the length of the stricture is too long to perform the tension-free anastomosis technique. Copyright © 2014 AEU. Published by Elsevier Espana. All rights reserved.

  14. Equilibrium and kinetics study on hexavalent chromium adsorption onto diethylene triamine grafted glycidyl methacrylate based copolymers.

    PubMed

    Maksin, Danijela D; Nastasović, Aleksandra B; Milutinović-Nikolić, Aleksandra D; Suručić, Ljiljana T; Sandić, Zvjezdana P; Hercigonja, Radmila V; Onjia, Antonije E

    2012-03-30

    Two porous and one non-porous crosslinked poly(glycidyl methacrylate-co-ethylene glycol dimethacrylate) [abbreviated PGME] were prepared by suspension copolymerization and functionalized with diethylene triamine [abbreviated PGME-deta]. Samples were characterized by elemental analysis, mercury porosimetry, scanning electron microscopy with energy-dispersive X-ray spectroscopy, and transmission electron microscopy. Kinetics of Cr(VI) sorption by PGME-deta were investigated in batch static experiments, in the temperature range 25-70°C. Sorption was rapid, with the uptake capacity higher than 80% after 30 min. Sorption behavior and rate-controlling mechanisms were analyzed using five kinetic models (pseudo-first order, pseudo-second order, Elovich, intraparticle diffusion and Bangham model). Kinetic studies showed that Cr(VI) adsorption adhered to the pseudo-second-order model, with definite influence of pore diffusion. Equilibrium data was tested with Langmuir, Freundlich and Tempkin adsorption isotherm models. Langmuir model was the most suitable indicating homogeneous distribution of active sites on PGME-deta and monolayer sorption. The maximum adsorption capacity from the Langmuir model, Q(max), at pH 1.8 and 25°C was 143 mg g(-1) for PGME2-deta (sample with the highest amino group concentration) while at 70°C Q(max) reached the high value of 198 mg g(-1). Thermodynamic parameters revealed spontaneous and endothermic nature of Cr(VI) adsorption onto PGME-deta. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. Efficacy and safety of botulinum toxin injection for interstitial cystitis/bladder pain syndrome: a systematic review and meta-analysis.

    PubMed

    Shim, Sung Ryul; Cho, Young Joo; Shin, In-Soo; Kim, Jae Heon

    2016-08-01

    To investigate the overall treatment efficacy and safety of botulinum toxin type A (BoNTA) injections compared with placebo in interstitial cystitis/bladder pain syndrome (IC/BPS). We conducted a systematic review and meta-analysis of the published literature in PubMed, Cochrane Library, and EMBASE on BoNTA use in IC/BPS. Outcome measures included changes of OLS, ICSI, ICPI, VAS, frequency, nocturia, FBC, Qmax, and PVR from baseline and also included adverse events. A total of five studies were included, with a total sample size of 252 subjects (133 subjects in the experimental group and 119 subjects in the control group). The duration of follow-up ranged from 8 to 12 weeks. The BoNTA dosage was from 50 to 200 U. The pooled overall SMD in the mean change of VAS for the BoNTA group versus the placebo group was -0.49 (95 % CI -0.74, -0.23). There were also significant improvements in ICPI and frequency. The other outcomes (ICSI, nocturia, Qmax, and FBC) were not statistically different between the two groups. Although BoNTA is not regulatory approved indication, this first evidence-based systematic review and meta-analysis of BoNTA injection for IC/BPS showed significant differences in efficacy of treatment compared with placebo, especially for pain control, and also showed no differences in the rate of procedure-related adverse events.

  16. Photoproduction of dileptons and photons in p -p collisions at the Large Hadron Collider energies

    NASA Astrophysics Data System (ADS)

    Ma, Zhi-Lei; Zhu, Jia-Qing

    2018-03-01

    The production of large pT dileptons and photons originating from photoproduction processes in p-p collisions at Large Hadron Collider energies is calculated. The comparisons between the exact treatment results and the ones of the equivalent photon approximation approach are expressed as the Q2 (the virtuality of photon) and pT distributions. The method developed by Martin and Ryskin is used for avoiding double counting when the coherent and incoherent contributions are considered simultaneously. The numerical results indicate that the equivalent photon approximation is only effective in small Q2 region and can be used for coherent photoproduction processes with proper choice of Qmax2 (the choices Qmax2˜s ^ or ∞ will cause obvious errors), but cannot be used for incoherent photoproduction processes. The exact treatment is needed to deal accurately with the photoproduction of large pT dileptons and photons.

  17. Copper removal by algae Gelidium, agar extraction algal waste and granulated algal waste: kinetics and equilibrium.

    PubMed

    Vilar, Vítor J P; Botelho, Cidália M S; Boaventura, Rui A R

    2008-03-01

    Biosorption of copper ions by an industrial algal waste, from agar extraction industry has been studied in a batch system. This biosorbent was compared with the algae Gelidium itself, which is the raw material for agar extraction, and the industrial waste immobilized with polyacrylonitrile (composite material). The effects of contact time, pH, ionic strength (IS) and temperature on the biosorption process have been studied. Equilibrium data follow both Langmuir and Langmuir-Freundlich models. The parameters of Langmuir equilibrium model were: q(max)=33.0mgg(-1), K(L)=0.015mgl(-1); q(max)=16.7mgg(-1), K(L)=0.028mgl(-1) and q(max)=10.3mgg(-1), K(L)=0.160mgl(-1) respectively for Gelidium, algal waste and composite material at pH=5.3, T=20 degrees C and IS=0.001M. Increasing the pH, the number of deprotonated active sites increases and so the uptake capacity of copper ions. In the case of high ionic strengths, the contribution of the electrostatic component to the overall binding decreases, and so the uptake capacity. The temperature has little influence on the uptake capacity principally for low equilibrium copper concentrations. Changes in standard enthalpy, Gibbs energy and entropy during biosorption were determined. Kinetic data at different solution pH (3, 4 and 5.3) were fitted to pseudo-first-order and pseudo-second-order models. The adsorptive behaviour of biosorbent particles was modelled using a batch reactor mass transfer kinetic model, which successfully predicts Cu(II) concentration profiles.

  18. Sorption of pure N2O to biochars and other organic and inorganic materials under anhydrous conditions

    USGS Publications Warehouse

    Cornelissen, Gerard; Rutherford, David W.; Arp, Hans Peter H.; Dorsch, Peter; Kelly, Charlene N.; Rostad, Colleen E.

    2013-01-01

    Suppression of nitrous oxide (N2O) emissions from soil is commonly observed after amendment with biochar. The mechanisms accounting for this suppression are not yet understood. One possible contributing mechanism is N2O sorption to biochar. The sorption of N2O and carbon dioxide (CO2) to four biochars was measured in an anhydrous system with pure N2O. The biochar data were compared to those for two activated carbons and other components potentially present in soils—uncharred pine wood and peat—and five inorganic metal oxides with variable surface areas. Langmuir maximum sorption capacities (Qmax) for N2O on the pine wood biochars (generated between 250 and 500 °C) and activated carbons were 17–73 cm3 g–1 at 20 °C (median 51 cm3 g–1), with Langmuir affinities (b) of 2–5 atm–1 (median 3.4 atm–1). Both Qmaxand b of the charred materials were substantially higher than those for peat, uncharred wood, and metal oxides [Qmax 1–34 cm3 g–1 (median 7 cm3 g–1); b 0.4–1.7 atm–1 (median 0.7 atm–1)]. This indicates that biochar can bind N2O more strongly than both mineral and organic soil materials. Qmax and b for CO2 were comparable to those for N2O. Modeled sorption coefficients obtained with an independent polyparameter—linear free-energy relationship matched measured data within a factor 2 for mineral surfaces but underestimated by a factor of 5–24 for biochar and carbonaceous surfaces. Isosteric enthalpies of sorption of N2O were mostly between −20 and −30 kJ mol–1, slightly more exothermic than enthalpies of condensation (−16.1 kJ mol–1). Qmax of N2O on biochar (50000–130000 μg g–1 biochar at 20 °C) exceeded the N2O emission suppressions observed in the literature (range 0.5–960 μg g–1 biochar; median 16 μg g–1) by several orders of magnitude. Thus, the hypothesis could not be falsified that sorption of N2O to biochar is a mechanism of N2O emission suppression.

  19. Removal of oil droplets from contaminated water using magnetic carbon nanotubes.

    PubMed

    Wang, Haitao; Lin, Kun-Yi; Jing, Benxin; Krylova, Galyna; Sigmon, Ginger E; McGinn, Paul; Zhu, Yingxi; Na, Chongzheng

    2013-08-01

    Water contaminated by oil and gas production poses challenges to the management of America's water resources. Here we report the design, fabrication, and laboratory evaluation of multi-walled carbon nanotubes decorated with superparamagnetic iron-oxide nanoparticles (SPIONs) for oil-water separation. As revealed by confocal laser-scanning fluorescence microscopy, the magnetic carbon nanotubes (MCNTs) remove oil droplets through a two-step mechanism, in which MCNTs are first dispersed at the oil-water interface and then drag the droplets with them out of water by a magnet. Measurements of removal efficiency with different initial oil concentration, MCNT dose, and mixing time show that kinetics and equilibrium of the separation process can be described by the Langmuir model. Separation capacity qt is a function of MCNT dose m, mixing time t, and residual oil concentration Ce at equilibrium: [Formula in text] where qmax, kw, and K are maximum separation capacity, wrapping rate constant, and equilibrium constant, respectively. Least-square regressions using experimental data estimate qmax = 6.6(± 0.6) g-diesel g-MCNT(-1), kw = 3.36(± 0.03) L g-diesel(-1) min(-1), and K = 2.4(± 0.2) L g-diesel(-1). For used MCNTs, we further show that over 80% of the separation capacity can be restored by a 10 min wash with 1 mL ethanol for every 6 mg MCNTs. The separation by reusable MCNTs provides a promising alternative strategy for water treatment design complementary to existing ones such as coagulation, adsorption, filtration, and membrane processes. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Preparation of a hollow porous molecularly imprinted polymer using tetrabromobisphenol A as a dummy template and its application as SPE sorbent for determination of bisphenol A in tap water.

    PubMed

    Li, Jin; Zhang, Xuebin; Liu, Yuxin; Tong, Hongwu; Xu, Yeping; Liu, Shaomin

    2013-12-15

    In this paper, a highly selective sample cleanup procedure combing dummy molecular imprinting and solid-phase extraction (DMIP-SPE) was developed for the isolation and determination of bisphenol A (BPA) in tap water. The novel hollow porous dummy molecularly imprinted polymer (HPDMIP) was prepared adopting a sacrificial support approach, using tetrabromobisphenol A (TBBPA), whose structure was similar to that of BPA, as the dummy template and mesoporous MCM-48 nanospheres as the support. Owing to a very short distance between the binding sites and the surface, a large surface area and a good steric structure to match its imprint molecules, the maximum adsorption capacities (Qmax) of the dummy-imprinted and non-imprinted sorbents for BPA were as high as 445 and 340 μmol g(-1), respectively, and the adsorption reached about 73% of Qmax in 10 min. Meanwhile, a method was developed for the determination of BPA using HPDMIP as a solid-phase extraction enrichment sorbent coupled with HPLC. Under the optimum experimental conditions, HPDMIP exhibited satisfactory results in the enrichment and determination of BPA in tap water with a recovery rate of 95-105%, and relative standard deviations of below 6%, and it can achieve a limit of detection as low as 3 ng mL(-1). The developed extraction protocol eliminated the effect of template leakage on quantitative analysis and could be applied for the determination of BPA in complicated functional samples. © 2013 Elsevier B.V. All rights reserved.

  1. Characteristic of theophylline imprinted monolithic column and its application for determination of xanthine derivatives caffeine and theophylline in green tea.

    PubMed

    Sun, Han-wen; Qiao, Feng-xia; Liu, Guang-yu

    2006-11-17

    Theophylline imprinted monolithic columns were designed and prepared for rapid separation of a homologous series of xanthine derivatives, caffeine, and theophylline by an in situ thermal-initiated copolymerization technique. Caffeine and theophylline were fully separated both under isocratic and gradient elutions on this kind of monolithic molecularly imprinted polymers (MIP) column. The broad peak showed in isocratic elution could be improved in gradient elution. Some chromatographic conditions such as mobile phase composition, flow rate, and the temperature on the retention times were investigated. Hydrogen bonding interaction and hydrophobic interaction played an important role in the retention and separation. The binding capacity was evaluated by static adsorption and Scatchard analysis, which showed that the dissociation constant (KD) and the maximum binding capacity (Qmax) were 1.50 mol/L, and 236 micromol/g for high affinity binding site, and 7.97 mol/L and 785 micromol/g for lower affinity binding site, respectively. Thermodynamic data (DeltaDeltaH and DeltaDeltaS) obtained by Van't Hoff plots revealed an enthalpy-controlled separation. The morphological characteristics of monolithic MIP were investigated by scanning electron microscope, which showed that both mesopores and macropores were formed in the monolith. The present monolithic MIP column was successfully applied for the quantitative determination of caffeine and theophylline in different kinds of green tea.

  2. Sensitivity of Deep Soil Organic Carbon Age to Sorption, Transport and Microbial Interactions - Insights from a Calibrated Process Model

    NASA Astrophysics Data System (ADS)

    Ahrens, B.; Schrumpf, M.; Reichstein, M.

    2013-12-01

    Subsoil soil organic carbon (SOC) is characterized by conventional radiocarbon ages on the order of centuries to millennia. Most vertically explicit SOC turnover models represent this persistence of deep SOC by one pool that has millennial turnover times. This approach lumps different stabilizing mechanisms such as chemical recalcitrance, sorptive stabilization and energy limitation into a single rate constant. As an alternative, we present a continuous, vertically explicit SOC decomposition model that allows for stabilization via sorption and microbial interactions (COMISSION model). We compare the COMISSION model with the SOC profile of a Haplic Podzol under a Norway spruce forest. In the COMISSION model two pools receive aboveground litter input and vertically distributed root litter input. The readily leachable and soluble fraction of litter input enters a dissolved organic carbon pool (DOC), while the rest enters the residue pool which represents polymeric, non-soluble SOC. The residue pool is depolymerized with extracellular enzymes produced by a microbial pool to enter the DOC pool which represents SOC potentially available for assimilation by microbes. The adsorption/desorption of DOC from/to mineral surfaces controls the availability of carbon in the DOC pool for assimilatory uptake by microbes. The sorption of DOC is modeled with dynamic Langmuir equations. The desorbed part of the DOC pool not only constitutes the substrate for the microbial pool, but is also transported via advection. Interactions of microbes with the residue and DOC pool are modeled with Michaelis-Menten kinetics - this not only allows representing ';priming', but also the retardation of decomposition via energy limitation in the deep soil where substrate is scarce. Further, soil organic matter is recycled within the soil profile through microbial processing - dead microbes either enter the DOC or the residue pool, and thereby also contribute to longer residence times with soil depth. First results of a calibration against SOC, SO14C, MOC and MO14C profiles (mineral associated organic carbon, density fraction >1.6 g cm-3) of a Haplic Podzol of the Waldstein site (Germany) show that we can use the maximum sorption capacity (qmax) estimated from batch sorption experiments to parameterize the dynamic Langmuir sorption equation. qmax could potentially be extrapolated to other soil profiles based on relations to iron and aluminum oxide contents. Although we are able to capture the secondary maximum of SOC contents in the Bh horizon with qmax from batch sorption experiments, our results indicate that the adsorption and desorption rates retrieved from batch sorption experiments are too fast to explain the low Δ14C values of the MOC. This could point to other processes apart from DOC sorption that trigger stabilization by organo-mineral associations with a stronger apparent irreversibility (e.g. inclusion in small pores). Alternatively, the conditions of batch sorption experiments (constant shaking in centrifuge tubes) might not be representative for in situ sorption conditions. Overall, we show how effective decomposition rates and 14C ages readily emerge from a combination of known stabilizing and destabilizing mechanisms and we discuss how to identify these processes with a model-data fusion framework.

  3. [Experiences in the treatment of benign prostatic hyperplasia with high power potassium-titanyl-phosphate (KTP) laser].

    PubMed

    Lipiński, Marek I; Peszyński-Drews, Cezary; Jeromin, Marek Z; Jeromin, Leszek M

    2006-01-01

    Benign prostatic hyperplasia (BPH) exist in about 70% men after 60 years old. High power KTP laser is a new tool for the treatment of BPH. 49 men were treated by photoselective vaporisation of the prostate (PVP) from August 2003 to May 2004. Thirty patients with follow-up period longer than 12 weeks (12 to 26 weeks) were analyzed. Preoperative prostate volume ranged from 31 to 136 cc. PSA range, estimated before treatment, was normal in all patients (pts). International Prostate Symptom Score (I-PSS) estimated before treatment was over 24 and Quality of Life (QoL) was over 3 in all pts. The maximum peak urinary flow (Qmax) before treatment ranged from 7.2 to 14.1 ml/s. One patient was catheterized with Foley catheter at the finish of the procedure. Two pts required catheterization in the first day after treatment. In two pts increasing of body temperature to 38 degrees C was observed in the first day after treatment. Twenty four hours after treatment haematuria required catheterization was observed in one patient. Seven days after treatment in 4 pts massive haematuria was observed (two required hospitalisation). In one patient because of urinary retention 4 weeks after PVP transurethral resection of the prostate was performed. Four weeks after PVP I-PSS decreased from 24 to 20 and after 12 weeks to 15. The Qmax increased and ranged from 11.3 ml/s to 17.1 ml/s 4 weeks after PVP and 12 weeks after PVP ranged from 15.1 to 22.8 ml/s. Photoselective vaporization of the prostate reduces I-PSS in all patients 12 weeks after procedure. Short follow-up period and a limited number of patients in study group cannot lead to ultimate conclusions. However the results encourage to undertaking further studies on PVP for the treatment of BPH.

  4. Usage of GreenLight HPS 180-W laser vaporisation for treatment of benign prostatic hyperplasia.

    PubMed

    Jovanović, M; Džamić, Z; Aćimović, M; Kajmaković, B; Pejčić, T

    2014-01-01

    Laser therapy has gained increasing acceptance as a relatively less invasive treatment for lower urinary tract symptoms (LUTS) due to benign prostatic hyperplasia (BPH). From the early procedure of interstitial laser coagulation through to the use of holmium laser enucleation of the prostate, there has been an expanding body of evidence on the efficacy of such procedures. One of the newer lasers is the Green Light HPS 180 W laser. Studies with this GreenLight laser (GLL) (American Medical Systems, Inc, Minnetonka, MN, USA) showing results as good as those of transurethral resection of the prostate (TURP). In this paper, the efficacy of the new GLL 180-W versus the gold standard TURP in patients with LUTS due to BPH was tested in a prospective clinical trial. To compare results of Green light laser (GLL) evaporisation of the prostatae and transurethral resection of the prostate (TURP) for treatment of BPH. MATERIJALS AND METHODS: A total of 62 patients with BPH were randomly assigned to two equal groups: TURP or GLL. Both groups were compared regarding all relevant preoperative, operative, and postoperative parameters. Functional results in terms of improvement of International Prostate Symptom Score (IPSS), maximum flow rate (Qmax), and postvoid residual (PVR) urine were assessed at 1, 3, 6 and 12 mo. A total of 62 patients completed 12 mo of follow-up in the TURP and GLL groups, respectively. Baseline characteristics were comparable. Mean operative time was significantly shorter for TURP. Compared to preoperative values, there was significant reduction in hemoglobin levels at the end of TURP only. A significant difference in favor of GLL was achieved regarding the duration of catheterization and hospital stay. In the GLL, no major intraoperative complications were recorded and none of the patients required blood transfusion. Among TURP patients, 6 required transfusion, 1 developed TUR syndrome, and capsule perforation was observed in 5 patients. There was dramatic improvement in Qmax, IPSS, and GLL compared with preoperative values and the degree of improvement was comparable in both groups at all time points of follow-up. Four TURP patients and one GLL patients developed bladder neck contracture treated by bladder neck incision; none in either group experienced urethral stricture or urinary incontinence. Compared to transurethral resection of the prostate, GreenLight HPS 180-W laser photoselective vaporization of the prostate is safe and effective in the treatment of patients suffering from lower urinary tract symptoms due to benign prostatic hyperplasia.

  5. Outcomes of minimally invasive simple prostatectomy for benign prostatic hyperplasia: a systematic review and meta-analysis.

    PubMed

    Lucca, Ilaria; Shariat, Shahrokh F; Hofbauer, Sebastian L; Klatte, Tobias

    2015-04-01

    (1) To assess the outcomes of minimally invasive simple prostatectomy (MISP) for the treatment of symptomatic benign prostatic hyperplasia in men with large prostates and (2) to compare them with open simple prostatectomy (OSP). A systematic review of outcomes of MISP for benign prostatic hyperplasia with meta-analysis was conducted. The article selection process was conducted according to the PRISMA guidelines. Twenty-seven observational studies with 764 patients were analyzed. The mean prostate volume was 113.5 ml (95 % CI 106-121). The mean increase in Qmax was 14.3 ml/s (95 % CI 13.1-15.6), and the mean improvement in IPSS was 17.2 (95 % CI 15.2-19.2). Mean duration of operation was 141 min (95 % CI 124-159), and the mean intraoperative blood loss was 284 ml (95 % CI 243-325). One hundred and four patients (13.6 %) developed a surgical complication. In comparative studies, length of hospital stay (WMD -1.6 days, p = 0.02), length of catheter use (WMD -1.3 days, p = 0.04) and estimated blood loss (WMD -187 ml, p = 0.015) were significantly lower in the MISP group, while the duration of operation was longer than in OSP (WMD 37.8 min, p < 0.0001). There were no differences in improvements in Qmax, IPSS and perioperative complications between both procedures. The small study sizes, publication bias, lack of systematic complication reporting and short follow-up are limitations. MISP seems an effective and safe treatment option. It provides similar improvements in Qmax and IPSS as OSP. Despite taking longer, it results in less blood loss and shorter hospital stay. Prospective randomized studies comparing OSP, MISP and laser enucleation are needed to define the standard surgical treatment for large prostates.

  6. The effect of land use change to maximum and minimum discharge in Cikapundung River Basin

    NASA Astrophysics Data System (ADS)

    Kuntoro, Arno Adi; Putro, Anton Winarto; Kusuma, M. Syahril B.; Natasaputra, Suardi

    2017-11-01

    Land use change are become issues for many river basin in the world, including Cikapundung River Basin in West Java. Cikapundung River is one of the main water sources of Bandung City water supply system. In the other hand, as one of the tributaries of Citarum River, Cikapundung also contributes to flooding in the Southern part of Bandung. Therefore, it is important to analyze the effect of land use change on Cikapundung river discharge, to maintain the reliability of water supply system and to minimize flooding in Bandung Basin. Land use map of Cikapundung River in 2009 shows that residential area (49.7%) and mixed farming (42.6%), are the most dominant land use type, while dry agriculture (19.4%) and forest (21.8%) cover the rest. The effect of land use change in Cikapundung River Basin is simulated by using Hydrological Simulation Program FORTRAN (HSPF) through 3 land use change scenarios: extreme, optimum, and existing. By using the calibrated parameters, simulation of the extreme land use change scenario with the decrease of forest area by 77.7% and increase of developed area by 57.0% from the existing condition resulted in increase of Qmax/Qmin ratio from 5.24 to 6.10. Meanwhile, simulation of the optimum land use change scenario with the expansion of forest area by 75.26% from the existing condition resulted in decrease of Qmax/Qmin ratio from 5.24 to 4.14. Although Qmax/Qmin ratio of Cikapundung is still relatively small, but the simulation shows the important of water resources analysis in providing river health indicator, as input for land use planning.

  7. Heat-transfer dynamics during cryogen spray cooling of substrate at different initial temperatures.

    PubMed

    Jia, Wangcun; Aguilar, Guillermo; Wang, Guo-Xiang; Nelson, J Stuart

    2004-12-07

    Cryogen spray cooling (CSC) is used to minimize the risk of epidermal damage during laser dermatologic therapy. However, the dominant mechanisms of heat transfer during the transient cooling process are incompletely understood. The objective of this study is to elucidate the physics of CSC by measuring the effect of initial substrate temperature (T0) on cooling dynamics. Cryogen was delivered by a straight-tube nozzle onto a skin phantom. A fast-response thermocouple was used to record the phantom temperature changes before, during and after the cryogen spray. Surface heat fluxes (q") and heat-transfer coefficients (h) were computed using an inverse heat conduction algorithm. The maximum surface heat flux (q"max) was observed to increase with T0. The surface temperature corresponding to q"max also increased with T0 but the latter has no significant effect on h. It is concluded that heat transfer between the cryogen spray and skin phantom remains in the nucleate boiling region even if T0 is 80 degrees C.

  8. Designation of River Klina-Skenderaj Inputs, in the Absence of Measurements (Monitoring)-Kosova

    NASA Astrophysics Data System (ADS)

    Osmanaj, Lavdim; Karahoda, Dafina

    2009-11-01

    The territory of Republic of Kosova is divided in four catchment basins, such as: Basin of river Drini i Bardhë, river Ibri, river Morava of Binca and river Lepenci. [1]The river Klina is left part of the Drini i Bardhë basin.The inputs are designated by the following authors:a) GIANDOTT - VISSENTINb) GA VRILOVICc) THE METHOD OF TYPICALHYDROGRAMAs a result of this studies derive the following parameters: the surface of basin F=77.75km2, width of main flow L=22.00km', width of basin Wb=68.00km', highest quota of the basin Hqb=1750m.l.m, highest quota of inflow Hi=600.00m.l.m, average difference of height D=303.5m, maximal water input: Qmax100 years=112.00 m3/s, an average produce of Alluvium W=980.76m3/s, specific produce of Alluvium Gyears=35270.57 m3/s, secondary conveyance of Alluvium Qa=14.70 m3/s.

  9. Efficacy, Safety, and Durability of 532 nm Laser Photovaporization of the Prostate with GreenLight 180 W XPS in Men with Acute Urinary Retention.

    PubMed

    Goueli, Ramy; Meskawi, Malek; Thomas, Dominique; Hueber, Pierre-Alain; Tholomier, Côme; Valdivieso, Roger; Te, Alexis; Zorn, Kevin C; Chughtai, Bilal

    2017-11-01

    We assessed the effectiveness and durability of 532 nm laser photovaporization with GreenLight XPS in men with and without preoperative urinary retention. From 2010 to 2017 we prospectively studied men who underwent photovaporization of the prostate (PVP) for obstructive lower urinary tract symptoms (LUTS) secondary to BPH. The cohort was retrospectively divided into those with catheter dependent retention and those with elective PVP. Primary endpoints were catheter-free rate and improvement in quality of life (QoL) scores, international prostate symptom score (IPSS), maximum urinary flow rate (Qmax), and postvoid residual (PVR). The secondary endpoints of the study were complication outcomes as defined by the standardized Clavien-Dindo grading system. One hundred thirty-seven men with preoperative retention and 195 men without preoperative retention underwent PVP. Men with preoperative retention were older (70 years vs 66 years; p < 0.001), had a higher American Society of Anesthesiology (ASA) score, and had a higher prevalence of neurologic disease (8% vs 2.6%; p = 0.04). These men also had a larger prostate volume (76 cc vs 69 cc; p < 0.001) and higher prostate specific antigen (5 ng/mL vs 2.7 ng/mL; p < 0.001) than those without retention. Patients with preoperative retention also had higher preoperative baseline IPSS and QoL score. After PVP they improved to values similar to those without retention, with durability up to 24 months. After PVP, men in preoperative retention had similar rates to fail their first void trial (18.2% vs 10.3%, p = 0.053). There was a 96% catheter-free rate in the men with preoperative retention. The rate of complication was higher in the nonretention group, specifically at 90 days (35.4% vs 21.2%; p = 0.009), with almost all the complications being Clavien-Dindo grade 2. PVP is an effective, safe, and durable treatment for men in acute urinary retention (AUR) with a catheter-free rate of 96%. The improvement is similar to those who did not present in AUR.

  10. k-t accelerated aortic 4D flow MRI in under two minutes: Feasibility and impact of resolution, k-space sampling patterns, and respiratory navigator gating on hemodynamic measurements.

    PubMed

    Bollache, Emilie; Barker, Alex J; Dolan, Ryan Scott; Carr, James C; van Ooij, Pim; Ahmadian, Rouzbeh; Powell, Alex; Collins, Jeremy D; Geiger, Julia; Markl, Michael

    2018-01-01

    To assess the performance of highly accelerated free-breathing aortic four-dimensional (4D) flow MRI acquired in under 2 minutes compared to conventional respiratory gated 4D flow. Eight k-t accelerated nongated 4D flow MRI (parallel MRI with extended and averaged generalized autocalibrating partially parallel acquisition kernels [PEAK GRAPPA], R = 5, TRes = 67.2 ms) using four k y -k z Cartesian sampling patterns (linear, center-out, out-center-out, random) and two spatial resolutions (SRes1 = 3.5 × 2.3 × 2.6 mm 3 , SRes2 = 4.5 × 2.3 × 2.6 mm 3 ) were compared in vitro (aortic coarctation flow phantom) and in 10 healthy volunteers, to conventional 4D flow (16 mm-navigator acceptance window; R = 2; TRes = 39.2 ms; SRes = 3.2 × 2.3 × 2.4 mm 3 ). The best k-t accelerated approach was further assessed in 10 patients with aortic disease. The k-t accelerated in vitro aortic peak flow (Qmax), net flow (Qnet), and peak velocity (Vmax) were lower than conventional 4D flow indices by ≤4.7%, ≤ 11%, and ≤22%, respectively. In vivo k-t accelerated acquisitions were significantly shorter but showed a trend to lower image quality compared to conventional 4D flow. Hemodynamic indices for linear and out-center-out k-space samplings were in agreement with conventional 4D flow (Qmax ≤ 13%, Qnet ≤ 13%, Vmax ≤ 17%, P > 0.05). Aortic 4D flow MRI in under 2 minutes is feasible with moderate underestimation of flow indices. Differences in k-space sampling patterns suggest an opportunity to mitigate image artifacts by an optimal trade-off between scan time, acceleration, and k-space sampling. Magn Reson Med 79:195-207, 2018. © 2018 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  11. Charge movement in a fast twitch skeletal muscle from rat.

    PubMed

    Simon, B J; Beam, K G

    1983-02-01

    Voltage-dependent charge movement in the rat omohyoid muscle was investigated using the three microelectrode voltage clamp technique. The charge that moved during a depolarization from the holding potential (-90 mV) to the test potential, V, increased with increasing V, saturating around 0 mV. The charge vs. voltage relationship was well fitted by Q = Q(max)/{1 + exp[-(V - V)/k]}, with Q(max) = 28.5 nC/muF, V = -34.2 mV, and k = 8.7 mV. Repolarization of the fiber from the test potential back to the holding potential caused an equal but opposite amount of charge to move. The kinetics of ON charge movement could be well described by a model developed for frog muscle by Horowicz and Schneider (1981b), which suggests that rat and frog charge movements are similar. This model failed to describe the kinetics of OFF charge movement for steps in potential from 0 mV to test potentials of -10 to -90 mV. OFF-charge movement rose to a peak more slowly and decayed more slowly than predicted by the theory.

  12. Differences in adsorption mechanisms of heavy metal by two different plant biomasses: reed and brown seaweed.

    PubMed

    Southichak, B; Nakano, K; Nomura, M; Chiba, N; Nishimura, O

    2009-01-01

    The adsorption of Pb(II) by two different biomaterials, reed (Phragmites australis) and brown seaweed (Sargassum horneri) biomass pretreated with CaCl(2), were compared in an attempt to explain the differences in adsorption performance between the two biosorbents. A very interesting characteristic was found in their individual adsorption performances; the Pb(II) adsorption capacity of brown seaweed (Q(max)=0.45 mmol/g) was much higher than that of reed (Q(max)=0.05 mmol/g), but its adsorption affinity (b=112 L/mmol) was much lower compared with that of reed (b=471 L/mmol). To elucidate the mechanism, the elemental components, ion exchange phenomenon and roles of functional groups of these two biosorbents were compared. The higher Pb(II) adsorption by brown seaweed could be due to its richness in total functional groups and calcium contents on its surface. In contrast, the functional complexity, higher zeta potential and pK(a) value (deprotonation state) of reed are believed to lead to its high adsorption affinity.

  13. Outward stabilization of the voltage sensor in domain II but not domain I speeds inactivation of voltage-gated sodium channels.

    PubMed

    Sheets, Michael F; Chen, Tiehua; Hanck, Dorothy A

    2013-10-15

    To determine the roles of the individual S4 segments in domains I and II to activation and inactivation kinetics of sodium current (INa) in NaV1.5, we used a tethered biotin and avidin approach after a site-directed cysteine substitution was made in the second outermost Arg in each S4 (DI-R2C and DII-R2C). We first determined the fraction of gating charge contributed by the individual S4's to maximal gating current (Qmax), and found that the outermost Arg residue in each S4 contributed ∼19% to Qmax with minimal contributions by other arginines. Stabilization of the S4's in DI-R2C and DII-R2C was confirmed by measuring the expected reduction in Qmax. In DI-R2C, stabilization resulted in a decrease in peak INa of ∼45%, while its peak current-voltage (I-V) and voltage-dependent Na channel availability (SSI) curves were nearly unchanged from wild type (WT). In contrast, stabilization of the DII-R2C enhanced activation with a negative shift in the peak I-V relationship by -7 mV and a larger -17 mV shift in the voltage-dependent SSI curve. Furthermore, its INa decay time constants and time-to-peak INa became more rapid than WT. An explanation for these results is that the depolarized conformation of DII-S4, but not DI-S4, affects the receptor for the inactivation particle formed by the interdomain linker between DIII and IV. In addition, the leftward shifts of both activation and inactivation and the decrease in Gmax after stabilization of the DII-S4 support previous studies that showed β-scorpion toxins trap the voltage sensor of DII in an activated conformation.

  14. Laser transurethral resection of the prostate: Safety study of a novel system of photoselective vaporization with high power diode laser in prostates larger than 80mL.

    PubMed

    Andrés, G; Arance, I; Gimbernat, H; Redondo, C; García-Tello, A; Angulo, J C

    2015-01-01

    To present the feasibility of photoselective vaporization of the prostate (PVP) with of a new diode laser-resection system. Surgical treatment of benign prostatic hyperplasia (BPH) is constantly evolving. Laser techniques are increasingly used in prostates of large size. A prospective study was performed to evaluate operative data and patient outcomes with PVP using high-power diode laser (HPD) and a novel quartz-head fiber with shovel shape in patients with prostate>80mL. Demographic data, operative time, hemoglobin loss, operative results (IPSS, quality of life (QoL), Qmax, post void residue (PVR), IIEF-5 and micturition diary) and complications following Clavien-Dindo classification are described. Thirty-one patients were included in the study. Sixteen (51.6%) were on active antiplatelet treatment and 12 (38.7%) had received anticoagulants before surgery. All cases were followed at least 6mo. No intraoperative or postoperative major complications occurred. Three patients (9.7%) had minor complications according to Clavien-Dindo classification. Twenty-seven (87.1%) were discharged on postoperative day one without catheter. There were significant improvements in IPSS, QoL, Qmax and PVR, both at 3 and 6mo (P<.0001), but sexual function according to IIEF-5 showed no differences. Urgency (any grade) increased at 3mo (48.4%; P=.002) and considerably decreased at 6mo (9.7%; P<.0001). This pilot experience with shovel shape fiber and HPD is encouraging. It shows that laser-resection is a safe procedure, achieving excellent results in terms of IPSS, QoL and Qmax in large prostates even in high-risk patients. Longer follow-up, comparative and randomized controlled studies are needed to widespread these results. Copyright © 2014 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  15. Development of a Simple Framework to Assess Hydrological Extremes using Solely Climate Data

    NASA Astrophysics Data System (ADS)

    Foulon, E.; Gagnon, P.; Rousseau, A. N.

    2014-12-01

    Extreme flow conditions such as droughts and floods are in general the direct consequences of short- to long-term weather/climate anomalies. For example, in southern Quebec, Canada, winter and summer 7-day low flows are due to summer and fall precipitations. Which prompts the question: is it possible to assess future extreme flow conditions from meteorological/climate indices or should we rely on the classical approach of using outputs of climate models as input to a hydrological model? The objective of this study is to assess six hydrological indices describing extreme flows at the watershed scale (Qmax, Qmin;7d, Qmin;30d for two seasons: winter and summer) using local climate indices without relying on the aforementioned classical approach. To establish the relationship between climate and hydrological indices, daily precipitations, minimum and maximum temperatures from 89 climate projections are used as inputs to a distributed hydrological model. River flows are simulated at the outlet of the Yamaska and Bécancour watersheds in Québec for the 1961-2100 periods. To identify the best predictors, hydrological indices are extracted from the flow series, and climate indices are computed for different time intervals (from a day up to four years). The difference between four-month, cumulative, climatic demand (P-ETP) explains 69% of the 7-day summer low flow during the calibration process. For both watersheds, preliminary findings indicate that the selected indices explain, on average, 38 and 60% of the variability of high- and low-flow indices, respectively. Overall, the results clearly illustrate that the change in the hydrological indices can be detected through the concurrent trends in the climate indices. The use of many climate projections ensures the relationships are not simulation-dependent and shows summer events are particularly at risk with increasing high flows and decreasing low flows. The development of a simple predictive tool to assess the impact of climate change on flows represents one of the major spin-off benefits of this study and may prooveto be useful to municipalities concerned with source water and flood management. Future work includes development of additional climate indices and application of the framework to more watersheds.

  16. Glacial lake monitoring in the Karakoram Range using historical Landsat Thematic Mapper archive (1982 - 2014)

    NASA Astrophysics Data System (ADS)

    Chan, J. Y. H.; Kelly, R. E. J.; Evans, S. G.

    2014-12-01

    Glacierized regions are one of the most dynamic land surface environments on the planet (Evans and Delaney, In Press). They are susceptible to various types of natural hazards such as landslides, glacier avalanches, and glacial lake outburst floods (GLOF). GLOF events are increasingly common and present catastrophic flood hazards, the causes of which are sensitive to climate change in complex high mountain topography (IPCC, 2013). Inundation and debris flows from GLOF events have repeatedly caused significant infrastructure damages and loss of human lives in the high mountain regions of the world (Huggel et al, 2002). The research is designed to develop methods for the consistent detection of glacier lakes formation during the Landsat Thematic Mapper (TM) era (1982 - present), to quantify the frequency of glacier lake development and estimate lake volume using Landsat imagery and digital elevation model (DEM) data. Landsat TM scenes are used to identify glacier lakes in the Shimshal and Shaksgam valley, particularly the development of Lake Virjeab in year 2000 and Kyagar Lake in 1998. A simple thresholding technique using Landsat TM infrared bands, along with object-based segmentation approaches are used to isolate lake extent. Lake volume is extracted by intersecting the lake extent with the DEM surface. Based on previous studies and DEM characterization in the region, Shuttle Radar Topography Mission (SRTM) DEM is preferred over Advanced Spaceborne Thermal Emission and Reflection (ASTER) GDEM due to higher accuracy. Calculated errors in SRTM height estimates are 5.81 m compared with 8.34 m for ASTER. SRTM data are preferred because the DEM measurements were made over short duration making the DEM internally consistent. Lake volume derived from the Landsat TM imagery and DEM are incorporated into a simple GLOF model identified by Clague and Matthews (1973) to estimate the potential peak discharge (Qmax) of a GLOF event. We compare the simple Qmax estimates with those from a more complex model of lake outflow time-varying discharge using the approach developed by Ng et al. (2007).

  17. Plant extracts: sense or nonsense?

    PubMed

    Madersbacher, Stephan; Berger, Ingrid; Ponholzer, Anton; Marszalek, Martin

    2008-01-01

    To assess the current role of plant extracts in the medical management of lower urinary tract symptoms due to benign prostatic enlargement/benign prostatic obstruction. In 2006, two clinical trials meeting the WHO benign prostatic hyperplasia consensus conference criteria (randomized against placebo/standard therapy, study duration 12 months) were published. One trial compared a saw palmetto extract with placebo. This industry-independent trial published in the New England Journal of Medicine was negative, that is, this saw palmetto extract had no effect on symptoms, Qmax and postvoid residual volume. In another trial, a saw palmetto/urtica combination was compared with tamsulosin. After 12 months, the improvement of symptoms was identical in both study arms. No detailed data were presented, however, on Qmax, postvoid residual or prostate volume. The biological mechanisms of plant extracts in vivo are still unknown and the numerous metaanalyses cannot supplement high-quality prospective trials. Further prospective studies according to WHO benign prostatic hyperplasia standards are required to reliably determine the role of plant extracts in contemporary lower urinary tract symptoms management and to be able to answer the question in the title: 'plant extracts: sense or nonsense?' Plant extracts are currently not recommended by the American and European Association of Urology benign prostatic hyperplasia guidelines.

  18. Superlattice-based thin-film thermoelectric modules with high cooling fluxes

    PubMed Central

    Bulman, Gary; Barletta, Phil; Lewis, Jay; Baldasaro, Nicholas; Manno, Michael; Bar-Cohen, Avram; Yang, Bao

    2016-01-01

    In present-day high-performance electronic components, the generated heat loads result in unacceptably high junction temperatures and reduced component lifetimes. Thermoelectric modules can, in principle, enhance heat removal and reduce the temperatures of such electronic devices. However, state-of-the-art bulk thermoelectric modules have a maximum cooling flux qmax of only about 10 W cm−2, while state-of-the art commercial thin-film modules have a qmax <100 W cm−2. Such flux values are insufficient for thermal management of modern high-power devices. Here we show that cooling fluxes of 258 W cm−2 can be achieved in thin-film Bi2Te3-based superlattice thermoelectric modules. These devices utilize a p-type Sb2Te3/Bi2Te3 superlattice and n-type δ-doped Bi2Te3−xSex, both of which are grown heteroepitaxially using metalorganic chemical vapour deposition. We anticipate that the demonstration of these high-cooling-flux modules will have far-reaching impacts in diverse applications, such as advanced computer processors, radio-frequency power devices, quantum cascade lasers and DNA micro-arrays. PMID:26757675

  19. Laparoscopic adenomectomy: 10 years of experience.

    PubMed

    Carpio Villanueva, J; Rosales Bordes, A; Ponce de León Roca, J; Montlleó González, M; Caparrós Sariol, J; Villavicencio Mavrich, H

    2018-04-01

    Lower urinary tract symptoms secondary to increased prostate volume are associated with ageing and are becoming more prevalent due to increased life expectancy. We present our experience with transperitoneal laparoscopic adenomectomy for the management of bladder outlet obstruction caused by benign prostatic enlargement. We performed a retrospective review of patients who underwent laparoscopic adenomectomy between 2005 and 2015. We recorded age, maximum flow and postvoid residual urine (preoperative and postoperative), surgical time, operative bleeding, weight and pathology, complications and duration of catheterisation and hospitalisation. We included 80 patients with a mean age of 70 years. The mean preoperative and postoperative Qmax was 8.21mL/s and 22.52mL/s, respectively. The mean preoperative and postoperative postvoid residual urine was 91.4mL and 14.2mL, respectively. The mean surgical time was 137.7min. Conversion to open surgery was necessary in one case due to intestinal injury. The mean intraoperative bleeding was 227.6mL. The mean hospital stay was 5.46 days, and the catheterisation time was 4.86 days. There were 13 complications, which were recorded according to the Clavien-Dindo system, 3 of which were severe. The mean weight of the surgical specimen was 80.02g. Pathology showed benign hyperplasia in 75 cases and prostate cancer in the remaining 5. Laparoscopic adenomectomy is a safe, reproducible technique with the same functional results as open surgery. Our series shows that this approach is useful and safe and has a low rate of complications. Copyright © 2017 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  20. Electron microscopic changes of detrusor in benign enlargement of prostate and its clinical correlation.

    PubMed

    Yadav, Sher Singh; Bhattar, Rohit; Sharma, Lokesh; Banga, Gautam; Sadasukhi, Trilok Chandra

    2017-01-01

    To study the ultra structural changes in bladder musculature in cases of BPE and their clinical relevance. In this descriptive longitudinal, controlled, observational study patients were enrolled into three groups, group 1, group 2A and group 2B. Control group (group-1) consisted of age matched normal male patients, who underwent surveillance or diagnostic cystoscopy for microscopic hematuria or irritative symptoms. Case group (group-2) comprised of patients with BPE, undergoing TURP. Case group (group-2) was further classified into: Category 2A (patients not on catheter) and cat-egory 2B (patients on catheter). All relevant clinical parameters like IPSS, prostate size, Qmax, PVR were recorded. Cystoscopy and bladder biopsy were performed in all patients. Various ultrastructural parameters like myocytes, fascicular pattern, interstitial tissue, nerve hypertrophy and cell junction pattern were analyzed under electron microscope and they were clinically correlated using appropriate statistical tests. Control group had significant difference as compared to case group in terms of baseline parameters like IPSS, flow rate and prostate size, both preoperatively and postoperatively, except for PVR, which was seen only preoperatively. There was statistically significant difference in ultrastructural patterns between case and control group in all five electron microscopic patterns. However, no significant difference was found between the subcategories of case groups. BPE is responsible for ultra structural changes in detrusor muscle and these changes remain persistent even after TURP. Nerve hypertrophy, which was not thoroughly discussed in previous studies, is also one of the salient feature of this study. Copyright® by the International Brazilian Journal of Urology.

  1. Cobalt sorption onto anaerobic granular sludge: isotherm and spatial localization analysis.

    PubMed

    van Hullebusch, Eric D; Gieteling, Jarno; Zhang, Min; Zandvoort, Marcel H; Daele, Wim Van; Defrancq, Jacques; Lens, Piet N L

    2006-01-24

    This study investigated the effect of different feeding regimes on the cobalt sorption capacity of anaerobic granular sludge from a full-scale bioreactor treating paper mill wastewater. Adsorption experiments were done with non-fed granules in monometal (only Co) and competitive conditions (Co and Ni in equimolar concentrations). In order to modify the extracellular polymeric substances and sulfides content of the granules, the sludge was fed for 30 days with glucose (pH 7, 30 degrees C, organic loading rate=1.2 g glucose l(-1) day-1) in the presence (COD/SO4(2-)=1) or absence of sulfate. The partitioning of the sorbed cobalt between the exchangeable, carbonates, organic matter/sulfides and residual fractions was determined using a sequential extraction procedure (modified Tessier). Experimental equilibrium sorption data for cobalt were analysed by the Langmuir, Freundlich and Redlich-Peterson isotherm equations. The total Langmuir maximal sorption capacity of the sludge fed with glucose and sulfate loaded with cobalt alone displayed a significantly higher maximal cobalt sorption (Qmax =18.76 mg g-1 TSS) than the sludge fed with glucose alone (Qmax =13.21 mg g-1 TSS), essentially due to an increased sorption capacity of the exchangeable (30-107%) and organic/sulfides fractions (70-30%). Environmental scanning electron microscopy coupled with an energy dispersive X-ray analysis of granular cross-sections showed that mainly iron minerals (i.e. iron sulfides) were involved in the cobalt accumulation. Moreover, the sorbed cobalt was mainly located at the edge of the granules. The sorption characteristics of the exchangeable and carbonates fractions fitted well to the Redlich-Peterson model (intermediate multi-layer sorption behaviour), whereas the sorption characteristics of the organic matter/sulfides and residual fractions fitted well to the Langmuir model (monolayer sorption behaviour). The organic matter/sulfides fraction displayed the highest affinity for cobalt for the three sludge types investigated.

  2. Navy Shipbuilding: Opportunities Exist to Improve Practices Affecting Quality

    DTIC Science & Technology

    2013-11-01

    Displacement (tons) Notable characteristics Qatar Petroleum and ExxonMobil Q-Max – Liquefied Natural Gas (LNG) Carrier (lead ship delivered June 2008...5In some instances, commercial ships, such as liquefied natural gas carriers or drill ships, may undergo additional sea trials...passengers; liquefied natural gas carriers; and offshore drilling ships, which in some instances can sit unanchored and drill for oil in water

  3. Plasmakinetic enucleation of prostate versus 160-W laser photoselective vaporization for the treatment of benign prostatic hyperplasia.

    PubMed

    Wang, Si-Jun; Mu, Xiao-Nan; Chen, Ji; Jin, Xun-Bo; Zhang, Shi-Bao; Zhang, Long-Yang

    2017-01-01

    To evaluate the safety and efficacy of plasmakinetic enucleation of the prostate (PKEP) for the treatment of symptomatic benign prostatic hyperplasia (BPH) compared with 160-W lithium triboride laser photoselective vaporization of the prostate (PVP). From February 2011 to July 2012, a prospective nonrandomized study was performed. One-hundred one patients underwent PKEP, and 110 underwent PVP. No severe intraoperative complications were recorded, and none of the patients in either group required a blood transfusion. Shorter catheterization time (38.14 ± 23.64 h vs 72.54 ± 28.38 h, P< 0.001) and hospitalization (2.32 ± 1.25 days vs 4.07 ± 1.23 days, P< 0.001) were recorded in the PVP group. At 12-month postoperatively, the PKEP group had a maintained and statistically improvement in International Prostate Symptom Score (IPSS) (4.07 ± 2.07 vs 5.00 ± 2.10; P< 0.001), quality of life (QoL) (1.08 ± 0.72 vs 1.35 ± 0.72; P= 0.007), maximal urinary flow rate (Qmax) (24.75 ± 5.87 ml s-1 vs 22.03 ± 5.04 ml s-1 ; P< 0.001), postvoid residual urine volume (PVR) (14.29 ± 6.97 ml vs 17.00 ± 6.11 ml; P= 0.001), and prostate-specific antigen (PSA) value (0.78 ± 0.57 ng ml-1 vs 1.27 ± 1.07 ng ml-1 ; P< 0.001). Both PKEP and PVP relieve low urinary tract symptoms (LUTS) due to BPH with low complication rates. PKEP can completely remove prostatic adenoma while the total amount of tissue removed by PVP is less than that can be removed by PKEP. Based on our study of the follow-up, PKEP provides better postoperative outcomes than PVP.

  4. 40 CFR 75.81 - Monitoring of Hg mass emissions and heat input at the unit level.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... concentration (µg/scm) from any of the test runs or 0.50 µg/scm, whichever is greater Qmax = Maximum potential...” in Equation 1. Also, note that if the highest Hg concentration measured in any test run is less than... updated value shall either be the highest Hg concentration measured in any of the test runs or 0.50 µg/scm...

  5. Aminopropyl-modified mesoporous molecular sieves as efficient adsorbents for removal of auxins

    NASA Astrophysics Data System (ADS)

    Moritz, Michał; Geszke-Moritz, Małgorzata

    2015-03-01

    In the present study, mesoporous siliceous materials grafted with 3-aminopropyltriethoxysilane (APTES) were examined as sorbents for removal of chosen plant growth factors (auxins) such as 1-naphthaleneacetic acid (NAA), indole-3-acetic acid (IAA) and indole-3-butyric acid (IBA). Four different types of mesoporous molecular sieves including SBA-15, PHTS, SBA-16 and MCF have been prepared via non-ionic surfactant-assisted soft templating method. Silica molecular sieves were thoroughly characterized by nitrogen adsorption-desorption analysis, powder X-ray diffraction (XRD), transmission electron microscopy (TEM), and Fourier-transform infrared spectroscopy (FT-IR). The maximum adsorption capacity (Qmax) for NAA, IAA and IBA was in the range from 51.0 to 140.8 mg/g and from 4.3 to 7.3 mg/g for aminopropyl-modified adsorbents and pure silicas, respectively. The best adsorption performance was observed for IAA entrapment using both APTES-functionalized SBA-15 and MCF matrices (Qmax of 140.8 and 137.0 mg/g, respectively) which can be ascribed to their larger pore volumes and pore diameters. Moreover, these silicas were characterized by the highest adsorption efficiency exceeding 90% at low pollutant concentration. The experimental points for adsorption of plant growth factors onto aminopropyl-modified mesoporous molecular sieves fitted well to the Langmuir equation.

  6. A Systematic Review of Prostatic Artery Embolization in the Treatment of Symptomatic Benign Prostatic Hyperplasia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuang, Michelle; Vu, Anthony; Athreya, Sriharsha, E-mail: sathreya@stjoes.ca

    PurposeTo summarize current evidence on outcomes and complications of prostatic artery embolization as a treatment for patients with lower urinary tract symptoms secondary to benign prostatic hyperplasia.Methods and MaterialsA database search of MEDLINE, Embase, Web of Science, and Cochrane Library was performed for published literature up to August 2015 concerning PAE in the treatment of BPH. Inclusion and exclusion criteria were applied by two independent reviewers, and disagreements were resolved by consensus. Peer-reviewed studies concerning PAE with BPH with a sample size >10 and at least one measured parameter were included.ResultsThe search yielded 193 articles, of which ten studies representingmore » 788 patients, with a mean age of 66.97 years, were included. Patients had LUTS ranging from moderate to severe. At 6 months following procedure, PV, PVR, Qmax, IPSS, and QoL were significantly improved (P < 0.05), while for PSA there was no significant change. At 12 and 24 months, PV, PSA, PVR, Qmax, IPSS, and QoL were significantly improved (P < 0.05). IIEF was unchanged at 6 and 12 months but was significantly reduced at 24 months.ConclusionThis suggests that PAE is effective in treating LUTS in the short and intermediate term.« less

  7. Mechanisms of Alizarin Red S and Methylene blue biosorption onto olive stone by-product: Isotherm study in single and binary systems.

    PubMed

    Albadarin, Ahmad B; Mangwandi, Chirangano

    2015-12-01

    The biosorption process of anionic dye Alizarin Red S (ARS) and cationic dye methylene blue (MB) as a function of contact time, initial concentration and solution pH onto olive stone (OS) biomass has been investigated. Equilibrium biosorption isotherms in single and binary systems and kinetics in batch mode were also examined. The kinetic data of the two dyes were better described by the pseudo second-order model. At low concentration, ARS dye appeared to follow a two-step diffusion process, while MB dye followed a three-step diffusion process. The biosorption experimental data for ARS and MB dyes were well suited to the Redlich-Peterson isotherm. The maximum biosorption of ARS dye, qmax = 16.10 mg/g, was obtained at pH 3.28 and the maximum biosorption of MB dye, qmax = 13.20 mg/g, was observed at basic pH values. In the binary system, it was indicated that the MB dye diffuses firstly inside the biosorbent particle and occupies the biosorption sites forming a monodentate complex and then the ARS dye enters and can only bind to untaken sites; forms a tridentate complex with OS active sites. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Safety and efficacy of tamsulosin, alfuzosin or silodosin as monotherapy for LUTS in BPH – a double-blind randomized trial

    PubMed Central

    Manohar, Chikka Moga Siddaiah; Nagabhushana, Mahadevappa; Sanjay, Ramachandra Pudakalkatti; Kamath, Ananth Janardhan; Keshavamurthy, Ramaiah

    2017-01-01

    Introduction Currently alpha1-adrenoceptor blockers (AB) are widely used as first-line therapy to improve lower urinary tract symptoms (LUTS) associated with benign prostatic hyperplasia (BPH). We compared the efficacy and safety profile of tamsulosin, alfuzosin and silodosin in LUTS due to BPH. Material and methods Consecutive consenting male patients (N = 269) undergoing medical management of BPH with AB from February 2012 to October 2015 were enrolled. Patients were randomized to a 0.4 mg tamsulosin (group T), 10 mg alfuzosin (group A) or a 8 mg silodosin (group S) by double-blind randomization. All patients were assessed for improvements and post-void residual urine (PVR) and for adverse drug events (ADE). Results IPSS showed significant improvement in Group S at the first week (11.7 ±4.18, p = 0.027) and at 3 months (7.97 ±3.84, p = 0.020). QOL showed significant improvement at 1 (2.2 ±0.76, p = 0.020), 4 (1.47 ±0.63, p <0.001) and 12 (1.2 ±0.66, p <0.001) weeks in Group S. The mean Qmax improvement was the maximum (13.76 ±2.44, p = 0.028) in Group S at 1 week. Reduction in PVR was the maximum in Group S, but it was not statistically significant. Adverse drug events (ADE) were observed in 20.07% (54/269) patients and distribution was similar in the three groups with decreasing incidence with progression of time. Conclusions Silodosin is the most efficacious AB with rapid onset of action. Silodosin also improves the quality of life in patients with LUTS due to BPH and objectively improves maximum flow rate. However, silodosin has more adverse events when compared to tamsulosin and alfuzosin. PMID:28721281

  9. The effects of age, metabolic syndrome, nocturnal polyuria and sleep disorders on nocturia.

    PubMed

    Sağlam, Hasan S; Gökkaya, C Serkan; Salar, Remzi; Memiş, Ali; Adsan, Oztuğ

    2013-01-01

    Nocturia, which is especially frequent among older men, adversely affects the individual's quality of life. It is regarded as one of the most bothersome lower urinary tract symptoms (LUTS). The aim of the study was to investigate factors contributing to the frequency of nocturia. Men ≥ 40 years with LUTS were enrolled in this study. After medical histories were taken and physical examinations conducted, biochemical tests and measures for LUTS were carried out. Anthropometric measurements were performed and Epworth scores (ES) were examined. Patients were divided into two groups with respect to nocturia: the first group having no nocturia or one incident of nocturia per night, and the second group with two or more nightly incidents of nocturia. The data were analyzed statistically; p < 0.05 was considered significant. A total of 118 consecutive patients (56 ± 10 years) were enrolled in the study. The first group consisted of 31 participants, while the second group contained 87 patients. The groups differed significantly with respect to age, body height, body weight, waist circumference and body mass index (BMI). ES, prostatic volumes, maximum flow rates (Qmax) and international prostate symptom scores (IPSS) were significantly different. Fasting blood glucose levels were similar for both groups. Homeostasis model assessment (HOMA) scores showed borderline significance. Insulin levels were different, while insulin resistance (IR) was similar between the groups. Nocturnal polyuria was associated with nocturia, systolic blood pressure and IPSS. Age, nocturnal polyuria, metabolic syndrome and sleep disturbances have been shown to be contributing factors in the frequency of nocturia and LUTS. Therefore, steps taken to alleviate factors that can be altered - such as hypertension, weight gain, sleep disturbances and IPSS - may improve the individual's quality of life.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bilhim, Tiago, E-mail: tiagobilhim@hotmail.com; Pisco, Joao; Rio Tinto, Hugo

    This study was designed to compare baseline data and clinical outcome between patients with prostate enlargement/benign prostatic hyperplasia (PE/BPH) who underwent unilateral and bilateral prostatic arterial embolization (PAE) for the relief of lower urinary tract symptoms (LUTS). This single-center, ambispective cohort study compared 122 consecutive patients (mean age 66.7 years) with unilateral versus bilateral PAE from March 2009 to December 2011. Selective PAE was performed with 100- and 200-{mu}m nonspherical polyvinyl alcohol (PVA) particles by a unilateral femoral approach. Bilateral PAE was performed in 103 (84.4 %) patients (group A). The remaining 19 (15.6 %) patients underwent unilateral PAE (groupmore » B). Mean follow-up time was 6.7 months in group A and 7.3 months in group B. Mean prostate volume, PSA, International prostate symptom score/quality of life (IPSS/QoL) and post-void residual volume (PVR) reduction, and peak flow rate (Qmax) improvement were 19.4 mL, 1.68 ng/mL, 11.8/2.0 points, 32.9 mL, and 3.9 mL/s in group A and 11.5 mL, 1.98 ng/mL, 8.9/1.4 points, 53.8 mL, and 4.58 mL/s in group B. Poor clinical outcome was observed in 24.3 % of patients from group A and 47.4 % from group B (p = 0.04). PAE is a safe and effective technique that can induce 48 % improvement in the IPSS score and a prostate volume reduction of 19 %, with good clinical outcome in up to 75 % of treated patients. Bilateral PAE seems to lead to better clinical results; however, up to 50 % of patients after unilateral PAE may have a good clinical outcome.« less

  11. Safety and efficacy of tamsulosin, alfuzosin or silodosin as monotherapy for LUTS in BPH - a double-blind randomized trial.

    PubMed

    Manohar, Chikka Moga Siddaiah; Nagabhushana, Mahadevappa; Karthikeyan, Vilvapathy Senguttuvan; Sanjay, Ramachandra Pudakalkatti; Kamath, Ananth Janardhan; Keshavamurthy, Ramaiah

    2017-06-30

    Currently alpha1-adrenoceptor blockers (AB) are widely used as first-line therapy to improve lower urinary tract symptoms (LUTS) associated with benign prostatic hyperplasia (BPH). We compared the efficacy and safety profile of tamsulosin, alfuzosin and silodosin in LUTS due to BPH. Consecutive consenting male patients (N = 269) undergoing medical management of BPH with AB from February 2012 to October 2015 were enrolled. Patients were randomized to a 0.4 mg tamsulosin (group T), 10 mg alfuzosin (group A) or a 8 mg silodosin (group S) by double-blind randomization. All patients were assessed for improvements and post-void residual urine (PVR) and for adverse drug events (ADE). IPSS showed significant improvement in Group S at the first week (11.7 ±4.18, p = 0.027) and at 3 months (7.97 ±3.84, p = 0.020). QOL showed significant improvement at 1 (2.2 ±0.76, p = 0.020), 4 (1.47 ±0.63, p <0.001) and 12 (1.2 ±0.66, p <0.001) weeks in Group S. The mean Qmax improvement was the maximum (13.76 ±2.44, p = 0.028) in Group S at 1 week. Reduction in PVR was the maximum in Group S, but it was not statistically significant. Adverse drug events (ADE) were observed in 20.07% (54/269) patients and distribution was similar in the three groups with decreasing incidence with progression of time. Silodosin is the most efficacious AB with rapid onset of action. Silodosin also improves the quality of life in patients with LUTS due to BPH and objectively improves maximum flow rate. However, silodosin has more adverse events when compared to tamsulosin and alfuzosin.

  12. Free uroflowmetry versus "Do-It-Yourself" uroflowmetry in the assessment of patients with lower urinary tract symptoms.

    PubMed

    Mombelli, Gabriella; Picozzi, Stefano; Messina, Giovanni; Truffelli, Dario; Marenghi, Carlo; Maffi, Gabriele; Carmignani, Luca

    2014-10-01

    We investigated the possibility that patients could carry out a urine flow assessment at home by themselves, in comfort, without expense and without the use of equipment. We compared this strategy of "Do-It-Yourself" (DIY) uroflowmetry with traditional, hospital uroflowmetry. One hundred and twenty patients were enrolled. The patients underwent conventional, free uroflowmetry in hospital. Subsequently, the patients were asked to carry out the following procedure at home: urinate into a graduated container to quantify the total voided volume and determine the flow time by measuring the duration of miction with a stopwatch or simply with the second hand of a clock. This procedure had to be performed three times without preparation. Hundred patients completed the study. The mean age of the patients analysed was 64.12 years. Their free uroflowmetry values were as follows: the mean voiding time was 44.28 s, the mean voided volume was 290.92 ml, the mean Qmax was 15.17 ml/s, the mean Qmean was 7.87 ml/s, and the mean post-void residual volume was 78.44 ml. The mean Qmean measured by the "DIY-uroflowmetry" was 8.33 ml/s, which was not statistically significantly different (P = 0.12). Assuming that pathological hospital uroflowmetry values are equivalent to a DIY-Qmean ≤10 ml/s and that normal hospital values are equivalent to a DIY-Qmean >10 ml/s, the concordance was 100 %. Our proposed DIY evaluation of urine flow, together with the International Prostatic Symptom Score (IPSS), provides a good estimate of the results of free uroflowmetry, enabling unnecessary hospital investigations to be avoided.

  13. Designing of a Quadrupole Paul Ion Trap

    NASA Astrophysics Data System (ADS)

    Kiyani, Abouzar; Abdollahzadeh, M.; Sadat Kiai, S. M.; Zirak, A. R.

    2011-08-01

    The ion motion equation in a Paul ion trap known as Mathieu differential equation has been solved for the first time by using Runge-Kutta methods with 4th, 6th, and 8th orders. The first stability regions in az - qz plane and the corresponding qmax values were determined and compared. Also, the first stability regions of , , , ions in the Vdc - Vac plane were drown, and the threshold voltages for the ion separation was investigated.

  14. Characterization of naphthalene degradation by Streptomyces sp. QWE-5 isolated from active sludge.

    PubMed

    Xu, Peng; Ma, Wencheng; Han, Hongjun; Hou, Baolin; Jia, Shengyong

    2014-01-01

    A bacterial strain, QWE-5, which utilized naphthalene as its sole carbon and energy source, was isolated and identified as Streptomyces sp. It was a Gram-positive, spore-forming bacterium with a flagellum, with whole, smooth, convex and wet colonies. The optimal temperature and pH for QWE-5 were 35 °C and 7.0, respectively. The QWE-5 strain was capable of completely degrading naphthalene at a concentration as high as 100 mg/L. At initial naphthalene concentrations of 10, 20, 50, 80 and 100 mg/L, complete degradation was achieved within 32, 56, 96, 120 and 144 h, respectively. Kinetics of naphthalene degradation was described using the Andrews equation. The kinetic parameters were as follows: qmax (maximum specific degradation rate) = 1.56 h⁻¹, Ks (half-rate constant) = 60.34 mg/L, and KI (substrate-inhibition constant) = 81.76 mg/L. Metabolic intermediates were identified by gas chromatography and mass spectrometry, allowing a new degradation pathway for naphthalene to be proposed. In this pathway, monooxygenation of naphthalene yielded naphthalen-1-ol. Further degradation by Streptomyces sp. QWE-5 produced acetophenone, followed by adipic acid, which was produced as a combination of decarboxylation and hydroxylation processes.

  15. Sorption of Cr(VI), Cu(II) and Pb(II) by growing and non-growing cells of a bacterial consortium.

    PubMed

    Sannasi, P; Kader, J; Ismail, B S; Salmijah, S

    2006-03-01

    This paper reports the sorption of three metallic ions, namely Cr(VI), Cu(II) and Pb(II) in aqueous solution by a consortium culture (CC) comprising an acclimatised mixed bacterial culture collected from point and non-point sources. Metal sorption capability of growing and non-growing cells at initial pH of between 3 and 8 in the 1-100mg/L concentration range were studied based on Q(max) and K(f) values of the Langmuir and linearised Freundlich isotherm models, respectively. Maximal metal loading was generally observed to be dependent on the initial pH. Growing cells displayed significant maximal loading (Q(max)) for Pb(II) (238.09 mg/g) and Cu(II) (178.87 mg/g) at pH 6 and at pH 7 for Cr(VI) (90.91 mg/g) compared to non-growing cells (p < 0.05). At the pH range of 6-8, growing cells showed higher loading capacity compared to non-growing cells i.e. 38-52% for Cr, 17-28% for Cu and 3-17% for Pb. At lower metal concentrations and at more acidic pH (3-4) however, non-growing cells had higher metal loading capacity than growing cells. The metal sorption capacity for both populations were as follows: Pb(II) > Cu(II) > Cr(VI).

  16. Biosorption of Cadmium by Non-Toxic Extracellular Polymeric Substances (EPS) Synthesized by Bacteria from Marine Intertidal Biofilms

    PubMed Central

    Camacho-Chab, Juan Carlos; Chan-Bacab, Manuel Jesús; Aguila-Ramírez, Ruth Noemí; Bartolo-Pérez, Pascual; Tabasco-Novelo, Carolina; Gaylarde, Christine; Ortega-Morales, Benjamín Otto

    2018-01-01

    Cadmium is a major heavy metal found in polluted aquatic environments, mainly derived from industrial production processes. We evaluated the biosorption of solubilized Cd2+ using the extracellular polymeric substances (EPS) produced by Bacillus sp. MC3B-22 and Microbacterium sp. MC3B-10 (Microbactan); these bacteria were originally isolated from intertidal biofilms off the coast of Campeche, Mexico. EPS were incubated with different concentrations of cadmium in ultrapure water. Residual Cd2+ concentrations were determined by Inductive Coupled Plasma-Optic Emission Spectrometry and the maximum sorption capacity (Qmax) was calculated according to the Langmuir model. EPS were characterized by X-ray photoelectron spectroscopy (XPS) before and after sorption. The Qmax of Cd2+ was 97 mg g−1 for Microbactan and 141 mg g−1 for MC3B-22 EPS, these adsorption levels being significantly higher than previously reported for other microbial EPS. In addition, XPS analysis revealed changes in structure of EPS after biosorption and showed that amino functional groups contributed to the binding of Cd2+, unlike other studies that show the carbohydrate fraction is responsible for this activity. This work expands the current view of bacterial species capable of synthesizing EPS with biosorbent potential for cadmium and provides evidence that different chemical moieties, other than carbohydrates, participate in this process. PMID:29439486

  17. Boronic acid-modified magnetic materials for antibody purification

    PubMed Central

    Dhadge, Vijaykumar L.; Hussain, Abid; Azevedo, Ana M.; Aires-Barros, Raquel; Roque, Ana C. A.

    2014-01-01

    Aminophenyl boronic acids can form reversible covalent ester interactions with cis-diol-containing molecules, serving as a selective tool for binding glycoproteins as antibody molecules that possess oligosaccharides in both the Fv and Fc regions. In this study, amino phenyl boronic acid (APBA) magnetic particles (MPs) were applied for the magnetic separation of antibody molecules. Iron oxide MPs were firstly coated with dextran to avoid non-specific binding and then with 3-glycidyloxypropyl trimethoxysilane to allow further covalent coupling of APBA (APBA_MP). When contacted with pure protein solutions of human IgG (hIgG) and bovine serum albumin (BSA), APBA_MP bound 170 ± 10 mg hIgG g−1 MP and eluted 160 ± 5 mg hIgG g−1 MP, while binding only 15 ± 5 mg BSA g−1 MP. The affinity constant for the interaction between hIgG and APBA_MP was estimated as 4.9 × 105 M−1 (Ka) with a theoretical maximum capacity of 492 mg hIgG adsorbed g−1 MP (Qmax), whereas control particles bound a negligible amount of hIgG and presented an estimated theoretical maximum capacity of 3.1 mg hIgG adsorbed g−1 MP (Qmax). APBA_MPs were also tested for antibody purification directly from CHO cell supernatants. The particles were able to bind 98% of IgG loaded and to recover 95% of pure IgG (purity greater than 98%) at extremely mild conditions. PMID:24258155

  18. Equilibrium and kinetic modelling of Cd(II) biosorption by algae Gelidium and agar extraction algal waste.

    PubMed

    Vilar, Vítor J P; Botelho, Cidália M S; Boaventura, Rui A R

    2006-01-01

    In this study an industrial algal waste from agar extraction has been used as an inexpensive and effective biosorbent for cadmium (II) removal from aqueous solutions. This biosorbent was compared with the algae Gelidium itself, which is the raw material for agar extraction. Equilibrium data follow both Langmuir and Redlich-Peterson models. The parameters of Langmuir equilibrium model are q(max)=18.0 mgg(-1), b=0.19 mgl(-1) and q(max)=9.7 mgg(-1), b=0.16 mgl(-1), respectively for Gelidium and the algal waste. Kinetic experiments were conducted at initial Cd(II) concentrations in the range 6-91 mgl(-1). Data were fitted to pseudo-first- and second-order Lagergren models. For an initial Cd(II) concentration of 91 mgl(-1) the parameters of the pseudo-first-order Lagergren model are k(1,ads)=0.17 and 0.87 min(-1); q(eq)=16.3 and 8.7 mgg(-1), respectively, for Gelidium and algal waste. Kinetic constants vary with the initial metal concentration. The adsorptive behaviour of biosorbent particles was modelled using a batch reactor mass transfer kinetic model. The model successfully predicts Cd(II) concentration profiles and provides significant insights on the biosorbents performance. The homogeneous diffusivity, D(h), is in the range 0.5-2.2 x10(-8) and 2.1-10.4 x10(-8)cm(2)s(-1), respectively, for Gelidium and algal waste.

  19. Enhanced removal of methylene blue and methyl violet dyes from aqueous solution using a nanocomposite of hydrolyzed polyacrylamide grafted xanthan gum and incorporated nanosilica.

    PubMed

    Ghorai, Soumitra; Sarkar, Asish; Raoufi, Mohammad; Panda, Asit Baran; Schönherr, Holger; Pal, Sagar

    2014-04-09

    The synthesis and characterization of a novel nanocomposite is reported that was developed as an efficient adsorbent for the removal of toxic methylene blue (MB) and methyl violet (MV) from aqueous solution. The nanocomposite comprises hydrolyzed polyacrylamide grafted onto xanthan gum as well as incorporated nanosilica. The synthesis exploits the saponification of the grafted polyacrylamide and the in situ formation of nanoscale SiO2 by a sol-gel reaction, in which the biopolymer matrix promotes the silica polymerization and therefore acts as a novel template for nanosilica formation. The detailed investigation of the kinetics and the adsorption isotherms of MB and MV from aqueous solution showed that the dyes adsorb rapidly, in accordance with a pseudo-second-order kinetics and a Langmuir adsorption isotherm. The entropy driven process was furthermore found to strongly depend on the point of zero charge (pzc) of the adsorbent. The remarkably high adsorption capacity of dyes on the nanocomposites (efficiency of MB removal, 99.4%; maximum specific removal Qmax, 497.5 mg g(-1); and efficiency of MV removal, 99.1%; Qmax, 378.8 mg g(-1)) is rationalized on the basis of H-bonding interactions as well as dipole-dipole and electrostatic interactions between anionic adsorbent and cationic dye molecules. Because of the excellent regeneration capacity the nanocomposites are considered interesting materials for the uptake of, for instance, toxic dyes from wastewater.

  20. [Stinging nettle root extract (Bazoton-uno) in long term treatment of benign prostatic syndrome (BPS). Results of a randomized, double-blind, placebo controlled multicenter study after 12 months].

    PubMed

    Schneider, T; Rübben, H

    2004-03-01

    Phytotherapy of BPS has a long tradition in Germany; nevertheless, data referring to single phytotherapeutic agents are rare. We therefore performed a randomized, double-blind, placebo-controlled multicenter study for 1 year with Bazoton uno (459 mg dry extract of stinging nettle roots) with 246 patients. The IPSS decreased on average from 18.7+/-0.3 to 13.0+/-0.5 with a statistically significant difference compared to placebo (18.5+/-0.3 to 13.8+/-0.5; p=0.0233). The median Q(max) increased by 3.0+/-0.4 ml/s in comparison to 2.9+/-0.4 ml/s (placebo), thus not statistically significantly different, as well as the median volume of residual urine, which changed from 35.5+/-3.4 ml before therapy to 20.0+/-2.8 ml and from 40.0+/-4.0 ml to 21.0+/-2.9 ml under placebo application. The number of adverse events (29/38) as well as urinary infections etc. (3/10 events) was smaller under Bazoton uno therapy compared to placebo. Treatment with Bazoton uno can therefore be considered a safe therapeutic option for BPS, especially for reducing irritative symptoms and BPS-associated complications due to the postulated antiphlogistic and antiproliferative effects of the stinging nettle extract. A strong increase of Q(max) or reduction of residual urine are not to be expected.

  1. Surgeon-tailored polypropylene mesh as a tension-free vaginal tape-obturator versus original TVT-O for the treatment of female stress urinary incontinence: a long-term comparative study.

    PubMed

    ElSheemy, Mohammed S; Fathy, Hesham; Hussein, Hussein A; Elsergany, Ragheb; Hussein, Eman A

    2015-10-01

    The objective of the study was to compare the safety and efficacy of surgeon-tailored polypropylene mesh (STM) through tension-free vaginal tape-obturator (TVT-O) versus original TVT-O in the treatment of stress urinary incontinence (SUI) aiming to decrease the cost of treatment. This is important in developing countries due to limited health care resources. A retrospective cohort study was done at the Urology and Gynecology Departments (dual-center), Cairo University from May 2007 to June 2010. Women evaluated by cough stress test, Stress and Urge Incontinence and Quality of Life Questionnaire (SUIQQ), maximum flow rate (Qmax), and abdominal leak point pressure (ALPP) with follow-up for at least 48 months were included. Patients with post-void residual urine > 100 ml, bladder capacity < 300 ml, or impaired compliance were excluded. The effect of different factors on outcome was compared between both groups pre- and postoperatively using the paired t, Wilcoxon signed rank, McNemar, chi-square, Fisher's exact, independent t, or Mann-Whitney tests. STM and TVT-O were inserted in 79 and 66 women, respectively. Intrinsic sphincter deficiency, ALPP, previous surgeries, associated urgency, urgency urinary incontinence (UUI), and prolapse were comparable in both groups. Operative duration was longer in STM by 10 min. No significant difference was found between both groups in complications (p = 0.462), cure (p = 0.654), and different indices of SUIQQ. In STM, 74 (93 %) were cured and 3 (4 %) improved, while SUI persisted in 2 (2 %) patients. In TVT-O, 59 (89 %) were cured and 4 (6 %) improved, while failure was detected in 3 (4 %) patients. The 5-year outcome is comparable between STM and TVT-O. Furthermore, STM is more economical due to our resterilizable modified helical passers and the cheap polypropylene mesh.

  2. Randomized, double-blind, placebo controlled pilot study of intradetrusor injections of onabotulinumtoxinA for the treatment of refractory overactive bladder persisting following surgical management of benign prostatic hyperplasia.

    PubMed

    Chughtai, Bilal; Dunphy, Claire; Lee, Richard; Lee, Daniel; Sheth, Seema; Marks, Leonard; Kaplan, Steven A; Te, Alexis E

    2014-04-01

    We assessed the efficacy of onabotulinumtoxinA (BOTOX, Allergan Inc., Irvine, CA, USA) in patients with refractory overactive bladder (OAB) after treatment for benign prostatic hyperplasia (BPH). This was a two-center, randomized, double-blinded pilot study conducted in patients with OAB secondary to bladder outlet obstruction (BOO), refractory to anticholinergic medication and persistent for greater than 3 months after surgical intervention to relieve obstruction, with an International Prostate Symptom Score (IPSS) > 12. Patients were randomized in 1:1 fashion to either 200 units of onabotulinumtoxinA versus placebo. Fifteen patients received onabotulinumtoxinA versus 13 who received placebo. Follow up was performed at 1 week and then 1, 3, 6, and 9 months. The primary endpoint was reduction in the frequency of micturition per 24 hours by 3-day voiding diary. Secondary endpoints were maximum flow rate (Qmax), post-void residual (PVR), and IPSS scores. Patients receiving onabotulinumtoxinA demonstrated significantly improved quality of life scores at 180 and 270 days after treatment (p = 0.02 and 0.03, respectively) as well as significantly lower International Consultation on Incontinence Questionnaire (ICIQ) scores (p < 0.05). Baseline urinary frequency was 10.5 versus 11.0 voids/day (p = 0.47). Frequency episodes improved from 11 episodes per day to 8 episodes per day in the treatment arm. The placebo arm did not have a decrease in frequency episodes. This response was durable up to 90 days, although this was not statistically significant. IPSS, PVR, and urgency were unchanged postoperatively in both groups. OnabotulinumtoxinA was safe in patients with refractory irritative lower urinary tracts symptoms after surgical treatment of BPH. There were improvements in daily frequency, although the results were not statistically significant. Larger trials are needed to help characterize the utility of onabotulinumtoxinA in the treatment of OAB secondary to BPH.

  3. Clinical, Laboratorial, and Urodynamic Findings of Prostatic Artery Embolization for the Treatment of Urinary Retention Related to Benign Prostatic Hyperplasia. A Prospective Single-Center Pilot Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Antunes, Alberto A.; Carnevale, Francisco C., E-mail: fcarnevale@uol.com.br; Motta Leal Filho, Joaquim M. da

    2013-08-01

    PurposeThis study was designed to describe the clinical, laboratorial, and urodynamic findings of prostatic artery embolization (PAE) in patients with urinary retention due to benign prostatic hyperplasia (BPH).MethodsA prospective study of 11 patients with urinary retention due to BPH was conducted. Patients underwent physical examination, prostate specific antigen (PSA) measurement, transrectal ultrasound, and magnetic resonance imaging. International prostate symptom score (IPSS), quality of life (QoL), and urodynamic testing were used to assess the outcome before and after 1 year.ResultsClinical success was 91 % (10/11 patients) with a mean follow-up of 22.3 months (range, 12-41 months). At the first year follow-up,more » the mean IPSS score was 2.8 points (p = 0.04), mean QoL was 0.4 points (p = 0.001), mean PSA decreased from 10.1 to 4.3 ng/mL (p = 0.003), maximum urinary flow (Qmax) improved from 4.2 to 10.8 mL/sec (p = 0.009), and detrusor pressure (Pdet) decreased from 85.7 to 51.5 cm H{sub 2}O (p = 0.007). Before PAE, Bladder Outlet Obstruction Index (BOOI) showed values >40 in 100 % of patients. After PAE, 30 % of patients were >40 (obstructed), 40 % were between 20 and 40 (undetermined), and 30 % were <20 (unobstructed). Patients with a BOOI <20 had higher PSA values at 1-day after PAE.ConclusionsClinical and urodynamic parameters improved significantly after PAE in patients with acute urinary retention due to BPH. Total PSA at day 1 after PAE was higher in patients with unobstructed values in pressure flow studies.« less

  4. Synthesis and application of Amberlite xad-4 functionalized with alizarin red-s for preconcentration and adsorption of rhodium (III)

    PubMed Central

    2012-01-01

    A new chelating resin was prepared by coupling Amberlite XAD-4 with alizarin red-s through an azo spacer, characterized by infra-red spectroscopy and thermal analysis and studied for Rh(III) preconcentration using inductively coupled plasma atomic emission spectroscopy (ICP-AES) for rhodium monitoring in the environment. The optimum pH for sorption of the metal ion was 6.5. The sorption capacity was found 2.1 mg/g of resin for Rh(III). A recovery of 88% was obtained for the metal ion with 1.5 M HCl as eluting agent. Kinetic adsorption data were analyzed by adsorption and desorption times of Rh(III) on modified resin. Scat chard analysis revealed that the homogeneous binding sites were formed in the polymers. The linear regression equation was Q/C = –1.3169Q + 27.222 (R2 = 0.9239), for Rh were formed in the SPE sorbent,Kd and Qmax for the affinity binding sites were calculated to be 0.76 μmol/mL and 20.67 μmol/g, respectively. The equilibrium data and parameters of Rh(III) adsorption on modified resin were analyzed by Langmuir, Freundlich, Temkin and Redlich–Peterson models. The experimental adsorption isotherm was in good concordance with Langmuir and Freundlich models (R2 > 0.998) and based on the Langmuir isotherm the maximum amount of adsorption (qmax) was 4.842 mg/g. The method was applied for rhodium ions determination in environmental samples. with high recovery (>80%). PMID:23369526

  5. Synthesis and application of Amberlite xad-4 functionalized with alizarin red-s for preconcentration and adsorption of rhodium (III).

    PubMed

    Sid Kalal, Hossein; Panahi, Homayon Ahmad; Hoveidi, Hassan; Taghiof, Mohammad; Menderjani, Mahnaz Taheri

    2012-09-18

    A new chelating resin was prepared by coupling Amberlite XAD-4 with alizarin red-s through an azo spacer, characterized by infra-red spectroscopy and thermal analysis and studied for Rh(III) preconcentration using inductively coupled plasma atomic emission spectroscopy (ICP-AES) for rhodium monitoring in the environment. The optimum pH for sorption of the metal ion was 6.5. The sorption capacity was found 2.1 mg/g of resin for Rh(III). A recovery of 88% was obtained for the metal ion with 1.5 M HCl as eluting agent. Kinetic adsorption data were analyzed by adsorption and desorption times of Rh(III) on modified resin. Scat chard analysis revealed that the homogeneous binding sites were formed in the polymers. The linear regression equation was Q/C = -1.3169Q + 27.222 (R2 = 0.9239), for Rh were formed in the SPE sorbent,Kd and Qmax for the affinity binding sites were calculated to be 0.76 μmol/mL and 20.67 μmol/g, respectively. The equilibrium data and parameters of Rh(III) adsorption on modified resin were analyzed by Langmuir, Freundlich, Temkin and Redlich-Peterson models. The experimental adsorption isotherm was in good concordance with Langmuir and Freundlich models (R2 > 0.998) and based on the Langmuir isotherm the maximum amount of adsorption (qmax) was 4.842 mg/g. The method was applied for rhodium ions determination in environmental samples. with high recovery (>80%).

  6. The structure of liquid water up to 360 MPa from x-ray diffraction measurements using a high Q-range and from molecular simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Skinner, L. B.; Galib, M.; Fulton, J. L.

    2016-04-07

    X-ray diffraction measurements of liquid water are reported at pressures up to 360 MPa corresponding to a density of 0.0373 molecules per Å3. The measurements were conducted at a spatial resolution corresponding to Qmax = 16 Å-1. The method of data analysis and measurement in this study follows the earlier benchmark results reported for water under ambient conditions having density of 0.0333 molecules per Å3 and Qmax = 20 Å-1 [J Chem Phys 138, 074506 (2013)]1 and at 70°C having density of 0.0327 molecules per Å3 and Qmax = 20 Å-1. [J Chem Phys 141, 214507 (2014)]2 The structure ofmore » water is very different at these three different T and P state points and thus they provide basis for evaluating the fidelity of molecular simulation. Measurements show that at 360 MPa, the 4 waters residing in the region between 2.3-3 Å are nearly unchanged: the peak position, shape and coordination number are nearly identical to their values under ambient conditions. However, in the region above 3 Å, large structural changes occur with the collapse of the well-defined 2nd shell and shifting of higher shells to shorter distances. The measured structure is compared to simulated structure using intermolecular potentials described by both first-principles methods (revPBE-D3) and classical potentials (TIP4P/2005 and mW). The DFT-based, revPBE-D3 provides the best overall representation of the ambient, high-temperature and high-pressure data while the TIP4P/2005 also captures the densification mechanism, whereby the non-bonded 5th nearest neighbor molecule, which encroaches the 1st shell at ambient pressure, is pushed further into the local tetrahedral arrangement at higher pressures by the more distant molecules filling the void space in the network between the 1st and 2nd shells. Acknowledgments: Thanks to Rick Spence and Doug Robinson for support with the beamline equipment at the Advanced Photon Source. The helpful comments of Valeria Molinero are acknowledged. This work was supported by the U.S. Department of Energy (DOE) office of Basic Energy Sciences grant Number BES DE-FG02-09ER46650 which supported, MD simulations, data analysis and manuscript preparation (LBS and JBP). DOE contract DE-AC02-06CH11357 supports operation of the Advanced Photon Source at Argonne National Laboratory. Work by JLF, MG, GSK and CJM was supported by the US Department of Energy, Office of Science, Office of Basic Energy Sciences, Division of Chemical Sciences, Geosciences & Biosciences. Pacific Northwest National Laboratory (PNNL) is a multiprogram national laboratory operated for DOE by Battelle.« less

  7. Kinetics of tetracycline, oxytetracycline, and chlortetracycline adsorption and desorption on two acid soils.

    PubMed

    Fernández-Calviño, David; Bermúdez-Couso, Alipio; Arias-Estévez, Manuel; Nóvoa-Muñoz, Juan Carlos; Fernández-Sanjurjo, Maria J; Álvarez-Rodríguez, Esperanza; Núñez-Delgado, Avelino

    2015-01-01

    The purpose of this work was to quantify retention/release of tetracycline, oxytetracycline, and chlortetracycline on two soils, paying attention to sorption kinetics and to implications of the adsorption/desorption processes on transfer of these pollutants to the various environmental compartments. We used the stirred flow chamber (SFC) procedure to achieve this goal. All three antibiotics showed high affinity for both soils, with greater adsorption intensity for soil 1, the one with the highest organic matter and Al and Fe oxides contents. Desorption was always <15%, exhibiting strong hysteresis in the adsorption/desorption processes. Adsorption was adequately modeled using a pseudo first-order equation with just one type of adsorption sites, whereas desorption was better adjusted considering both fast and slow sorption sites. The adsorption maximum (qmax) followed the sequence tetracycline > oxytetracycline > chlortetracycline in soil 1, with similar values for the three antibiotics and the sequence tetracycline > chlortetracycline > oxytetracycline in soil 2. The desorption sequences were oxytetracycline > tetracycline > chlortetracycline in soil 1 and oxytetracycline > chlortetracycline > tetracycline in soil 2. In conclusion, the SFC technique has yielded new kinetic data regarding tetracycline, oxytetracycline, and chlortetracycline adsorption/desorption on soils, indicating that it can be used to shed further light on the retention and transport processes affecting antibiotics on soils and other media, thus increasing knowledge on the behavior and evolution of these pharmaceutical residues in the environment.

  8. Marine macroalga Sargassum horneri as biosorbent for heavy metal removal: roles of calcium in ion exchange mechanism.

    PubMed

    Southichak, B; Nakano, K; Nomura, M; Chiba, N; Nishimura, O

    2008-01-01

    Brown seaweed Sargassum horneri, a troublesome biomass scattered along the seashore, was utilized as a biosorbent for Pb(II) removal from aqueous solutions. The Pb(II) adsorption by brown seaweed was enhanced by pretreatment with CaCl(2), and the Langmuir adsorption isotherm equation showed a maximum capacity of a Q(max) of 0.696 mmol/g and a b value of 94.33 L/mmol. Results obtained from the mass-balance equation derived from the simulation model of the Langmuir adsorption isotherm suggested that the adsorption performance of brown seaweed biosorbent was sufficient to reduce the concentration of Pb(II) to meet the range of WHO guideline. The mechanism, as elucidated using pH monitoring, adsorption rate and ion exchange model, involved the rapid pH change of metal solutions that led to high reaction rate and Pb(II) uptake in the first 30 min of the biosorption process. The energy X-ray analysis's result confirmed the sharp reduction of calcium content in the biosorbent after Pb(II) adsorption. The amount of calcium ions released from the biosorbent was about 1.5 times the amount of Pb(II) adsorbed and proved the role of calcium in the ion exchange mechanism. These adsorption equilibrium and mechanistic studies provide useful information for system design and performance prediction of biosorption processes. (c) IWA Publishing 2008.

  9. Production of activated carbon from biodiesel solid residues: An alternative for hazardous metal sorption from aqueous solution.

    PubMed

    Ribeiro, Rita F L; Soares, Vitor C; Costa, Letícia M; Nascentes, Clésia C

    2015-10-01

    In this study, the potential for the sorption of Pb(2+) and Cd(2+) from aqueous solutions using HNO3-treated activated carbon (TAC) obtained from radish press cake (Raphanus sativus L.), a solid residue from biodiesel production, was investigated. Activated carbon (AC) was obtained by physical activation with CO2(g). Chemical modification with HNO3 was employed to increase the sorption capability of the AC. The sorption of Pb(2+) and Cd(2+) was studied in monometallic systems in equilibrium with different metal-ion concentrations (10-400 mg L(-1)). The experimental sorption equilibrium data were fit to the Langmuir and Freundlich isotherm models. The maximum sorption capacity (qmax) obtained for AC from the Langmuir isotherm was 45.5 mg g(-1) for Cd(2+) and 250 mg g(-1) for Pb(2+). Moreover, TAC presented qmax of 166.7 mg g(-1) (1.48 mmol g(-1)) for Cd(2+) and 500.0 mg g(-1) (2.41 mmol g(-1)) for Pb(2+)showing the effect of chemical modification. Sorption-desorption studies showed that the interaction between metals and TAC is reversible and this sorbent can be reused for several consecutive cycles. Furthermore, the sorption of Cd(2+) and Pb(2+) by TAC was not affected by the presence of competing ions. The experimental data obtained in this study indicated that this solid residue is viable for the production of sorbents that remove metals, such as cadmium and lead, from wastewaters and thereby contribute to the sustainable development of the production of biodiesel. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. OnabotulinumtoxinA injection therapy in men with LUTS due to primary bladder-neck dysfunction: objective and patient-reported outcomes.

    PubMed

    Sacco, Emilio; Tienforti, Daniele; Bientinesi, Riccardo; D'Addessi, Alessandro; Racioppi, Marco; Pinto, Francesco; Totaro, Angelo; Vittori, Matteo; D'Agostino, Daniele; Bassi, Pierfrancesco

    2014-01-01

    To determine efficacy and safety of OnabotulinumtoxinA (BoNT-A) injection therapy in medically refractory patients with lower urinary tract symptoms (LUTS) due to primary bladder-neck dysfunction (PBND). Thirty-five consecutive ambulatory males diagnosed with PBND and refractory to medical therapy, with IPSS > 15, Qmax < 15 ml/sec, and total prostate volume < 30 cm(3), were screened from January 2010 to December 2011. Eligible patients underwent transurethral bladder-neck injection of BoNT-A (200 U, 50 U/ml × 4 sites) and were assessed at baseline, 2-, 6-, 9-, and 12-month postprocedure and until duration of clinical response. The primary outcome was the change from baseline in total IPSS, and secondary outcome were storage- and voiding-IPSS, QoL score, Qmax, and postvoiding residual volume (PVR), patient-reported outcomes. Adverse effects were also recorded, including ejaculatory dysfunctions. Of 30 enrolled patients (mean age 33.8 years), 29 (96.7%) completed the study. A statistically significant improvement of total IPSS was observed from 21.9 at baseline, to 7.8, 10.3, and 16.6 at 2, 6, and 9 months, respectively (P < 0.000). Statistically significant improvements from baseline of storage- and voiding-IPSS, QoL score, Qmax, and PVR were also observed until 9-month postprocedure. The proportion of patients with overall satisfaction was favorable although decreasing from 80% at 2 months, to 44.8% at 12 months. No significant adverse effects or ejaculatory dysfunctions were noted. BoNT-A injection therapy appears effective and safe in medically refractory men with PBND, although repeated procedures are required for long-term sustained benefit. Randomized controlled trials are warranted in order to corroborate these results. © 2013 Wiley Periodicals, Inc.

  11. Charge immobilization of the voltage sensor in domain IV is independent of sodium current inactivation.

    PubMed

    Sheets, Michael F; Hanck, Dorothy A

    2005-02-15

    Recovery from fast inactivation in voltage-dependent Na+ channels is associated with a slow component in the time course of gating charge during repolarization (i.e. charge immobilization), which results from the slow movement of the S4 segments in domains III and IV (S4-DIII and S4-DIV). Previous studies have shown that the non-specific removal of fast inactivation by the proteolytic enzyme pronase eliminated charge immobilization, while the specific removal of fast inactivation (by intracellular MTSET modification of a cysteine substituted for the phenylalanine in the IFM motif, ICMMTSET, in the inactivation particle formed by the linker between domains III and IV) only reduced the amount of charge immobilization by nearly one-half. To investigate the molecular origin of the remaining slow component of charge immobilization we studied the human cardiac Na+ channel (hH1a) in which the outermost arginine in the S4-DIV, which contributes approximately 20% to total gating charge (Qmax), was mutated to a cysteine (R1C-DIV). Gating charge could be fully restored in R1C-DIV by exposure to extracellular MTSEA, a positively charged methanethiosulphonate reagent. The RIC-DIV mutation was combined with ICMMTSET to remove fast inactivation, and the gating currents of R1C-DIV-ICM(MTSET) were recorded before and after modification with MTSEAo. Prior to MTSEAo, the time course of the gating charge during repolarization (off-charge) was best described by a single fast time constant. After MTSEA, the off-charge had both fast and slow components, with the slow component accounting for nearly 35% of Qmax. These results demonstrate that the slow movement of the S4-DIV during repolarization is not dependent upon the normal binding of the inactivation particle.

  12. Revisiting the hydration structure of aqueous Na +

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Galib, M.; Baer, M. D.; Skinner, L. B.

    In this paper, a combination of theory, X-ray diffraction (XRD) and extended x-ray absorption fine structure (EXAFS) are used to probe the hydration structure of aqueous Na +. The high spatial resolution of the XRD measurements corresponds to Qmax = 24 Å –1 while the first-reported Na K-edge EXAFS measurements have a spatial resolution corresponding to 2k = Qmax = 16 Å –1. Both provide an accurate measure of the shape and position of the first peak in the Na–O pair distribution function, g NaO(r). The measured Na–O distances of 2.384 ± 0.003 Å (XRD) and 2.37 ± 0.024 Åmore » (EXAFS) are in excellent agreement. These measurements show a much shorter Na–O distance than generally reported in the experimental literature (Na–O avg ~ 2.44 Å) although the current measurements are in agreement with recent neutron diffraction measurements. The measured Na–O coordination number from XRD is 5.5 ± 0.3. The measured structure is compared with both classical and first-principles density functional theory (DFT) simulations. Both of the DFT-based methods, revPBE and BLYP, predict a Na–O distance that is too long by about 0.05 Å with respect to the experimental data (EXAFS and XRD). The inclusion of dispersion interactions (–D3 and –D2) significantly worsens the agreement with experiment by further increasing the Na–O distance by 0.07 Å. In contrast, the use of a classical Na–O Lennard-Jones potential with SPC/E water accurately predicts the Na–O distance as 2.39 Å although the Na–O peak is over-structured with respect to experiment.« less

  13. Insulin-like growth factor-1 enhances rat skeletal muscle charge movement and L-type Ca2+ channel gene expression

    PubMed Central

    Wang, Zhong-Min; Laura Messi, María; Renganathan, Muthukrishnan; Delbono, Osvaldo

    1999-01-01

    We investigated whether insulin-like growth factor-1 (IGF-1), an endogenous potent activator of skeletal muscle proliferation and differentiation, enhances L-type Ca2+ channel gene expression resulting in increased functional voltage sensors in single skeletal muscle cells. Charge movement and inward Ca2+ current were recorded in primary cultured rat myoballs using the whole-cell configuration of the patch-clamp technique. Ca2+ current and maximum charge movement (Qmax) were potentiated in cells treated with IGF-1 without significant changes in their voltage dependence. Peak Ca2+ current in control and IGF-1-treated cells was -7·8 ± 0·44 and -10·5 ± 0·37 pA pF−1, respectively (P < 0·01), whilst Qmax was 12·9 ± 0·4 and 22·0 ± 0·3 nC μF−1, respectively (P < 0·01). The number of L-type Ca2+ channels was found to increase in the same preparation. The maximum binding capacity (Bmax) of the high-affinity radioligand [3H]PN200-110 in control and IGF-1-treated cells was 1·21 ± 0·25 and 3·15 ± 0·5 pmol (mg protein)−1, respectively (P < 0·01). No significant change in the dissociation constant for [3H]PN200-110 was found. Antisense RNA amplification showed a significant increase in the level of mRNA encoding the L-type Ca2+ channel α1-subunit in IGF-1-treated cells. This study demonstrates that IGF-1 regulates charge movement and the level of L-type Ca2+ channel α1-subunits through activation of gene expression in skeletal muscle cells. PMID:10087334

  14. Urodynamics findings in transverse myelitis patients with lower urinary tract symptoms: Results from a tertiary referral urodynamic center.

    PubMed

    Gliga, Louise A; Lavelle, Rebecca S; Christie, Alana L; Coskun, Burhan; Greenberg, Benjamin M; Carmel, Maude E; Lemack, Gary E

    2017-02-01

    To characterize urodynamic findings in patients referred with transverse myelitis (TM) and lower urinary tract symptoms (LUTS), as well as to identify any characteristics predictive of urodynamics findings. This is a retrospective review of an IRB-approved neurogenic bladder database of patients followed by a single surgeon between 2001 and 2013. Patient characteristics, questionnaire data, radiologic studies, and urodynamic parameters were analyzed. Of the 836 patients in the neurogenic bladder database, 28 patients (17 females, 11 males) were referred with a principle diagnosis of TM (3%). Twenty-one of twenty-eight patients (75%) underwent urodynamics testing. Bladder management at initial urologic evaluation was CIC or urethral catheter for 16/28 patients (57.1%). Median MCC was 303 ml (85-840 ml), detrusor overactivity (DO) was present in 16/21 (76%), detrusor sphincter dyssynergia (DSD) in 10/21 (48%), and decreased compliance in 7/21 (33%). For those voiding, mean Qmax was 12 ± 10 ml/sec and pdet at Qmax was 41 ± 17 cmH 2 O. Longitudinally extensive TM (LETM) was the only patient characteristic associated with DO (P = 0.0276). No other patient characteristics were associated with urodynamics parameters. Significant urodynamic testing abnormalities are noted in the majority of TM patients undergoing urodynamics, with 95% having DO, DSD, altered compliance, or detrusor underactivity. Other than the association between LETM and DO, there were no patient characteristics predictive of urodynamics findings. Based on the severity of urodynamics findings in our series, patients with TM and LUTS should have thorough baseline urological evaluations including urodynamics and be offered ongoing surveillance. Neurourol. Urodynam. 36:360-363, 2017. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  15. Revisiting the hydration structure of aqueous Na +

    DOE PAGES

    Galib, M.; Baer, M. D.; Skinner, L. B.; ...

    2017-02-27

    In this paper, a combination of theory, X-ray diffraction (XRD) and extended x-ray absorption fine structure (EXAFS) are used to probe the hydration structure of aqueous Na +. The high spatial resolution of the XRD measurements corresponds to Qmax = 24 Å –1 while the first-reported Na K-edge EXAFS measurements have a spatial resolution corresponding to 2k = Qmax = 16 Å –1. Both provide an accurate measure of the shape and position of the first peak in the Na–O pair distribution function, g NaO(r). The measured Na–O distances of 2.384 ± 0.003 Å (XRD) and 2.37 ± 0.024 Åmore » (EXAFS) are in excellent agreement. These measurements show a much shorter Na–O distance than generally reported in the experimental literature (Na–O avg ~ 2.44 Å) although the current measurements are in agreement with recent neutron diffraction measurements. The measured Na–O coordination number from XRD is 5.5 ± 0.3. The measured structure is compared with both classical and first-principles density functional theory (DFT) simulations. Both of the DFT-based methods, revPBE and BLYP, predict a Na–O distance that is too long by about 0.05 Å with respect to the experimental data (EXAFS and XRD). The inclusion of dispersion interactions (–D3 and –D2) significantly worsens the agreement with experiment by further increasing the Na–O distance by 0.07 Å. In contrast, the use of a classical Na–O Lennard-Jones potential with SPC/E water accurately predicts the Na–O distance as 2.39 Å although the Na–O peak is over-structured with respect to experiment.« less

  16. Evaluation of adsorption capacities of humic acids extracted from Algerian soil on polyaniline for application to remove pollutants such as Cd(II), Zn(II) and Ni(II) and characterization with cavity microelectrode.

    PubMed

    Terbouche, Achour; Ramdane-Terbouche, Chafia Ait; Hauchard, Didier; Djebbar, Safia

    2011-01-01

    The adsorption capacities of new humic acids isolated from Yakouren forest (YHA) and Sahara (Tamenrasset: THA) soils (Algeria) and commercial humic acid (PFHA) on polyaniline emeraldine base (PEB) were studied at pH 6.6. Also the adsorption of heavy metals such as Cd2+, Zn2+ and Ni2+ on humic acid-polyaniline systems (HA-PEB) was investigated at the same conditions. HA-PEB compounds were characterized by scanning electron microscopy (SEM), infrared spectrometry and cavity microelectrode. In addition, batch adsorption and cavity microelectrode were used in the adsorption study of Cd2+, Zn2+ and Ni2+ on HA-PEB. To develop biocaptors of polluting metals using a cavity microelectrode modified by HA-PEB systems, the adsorption kinetic and adsorption capacity were investigated. The SEM analysis showed that the presence of humic acid affected the PEB surface and caused the formation of a granular morphology. The maximum adsorption capacities (q(max)) of PFHA, THA and YHA determined by adsorption isotherms were 91.31, 132.1 and 151.0 mg/g, respectively. Batch adsorption results showed that q(max) of Cd2+, Zn2+ and Ni2+ on HA-PEB followed the order: THA-PEB > YHA-PEB > PFHA-PEB. The voltammograms obtained with HA-PEB modified cavity microelectrode showed the appearance of new redox couples reflecting the adsorption of HA on PEB. Metal-humic acid-polyaniline voltammograms were characterized by appearance of oxidation-reduction couples or reduction wave corresponding to metal. Finally, the result may be exploited to develop a biocaptor based on the cavity microelectrode amended by THA-PEB and YHA-PEB.

  17. Rapid adsorptive removal of toxic Pb(2+) ion from aqueous solution using recyclable, biodegradable nanocomposite derived from templated partially hydrolyzed xanthan gum and nanosilica.

    PubMed

    Ghorai, Soumitra; Sarkar, Amit Kumar; Pal, Sagar

    2014-10-01

    This work studied the application of a novel biodegradable nanocomposite based on partially hydrolyzed polyacrylamide grafted xanthan gum and nanosilica (h-XG/SiO2) towards efficient and rapid removal of toxic Pb(2+) ions from aqueous environment. The uptake ability of Pb(2+) using h-XG/SiO2 has been studied in batch adsorption experiments with variation of adsorption parameters. The excellent removal rate (99.54% adsorption within 25min) and superior adsorption capacity (Qmax=1012.15mgg(-1)) of the composite material have been explained on the basis of synergistic and chelating effects of h-XG/SiO2 with Pb(2+) ion through electrostatic interactions. The kinetics, isotherm and thermodynamics studies reveal that Pb(2+) adsorb rapidly on nanocomposite surface, which is in agreement with pseudo-second-order kinetics and Langmuir adsorption isotherm models. In consequence of excellent adsorption as well as regeneration characteristics of nanocomposite, it has been found to be a promising adsorbent towards removal of Pb(2+) ions from battery industry wastewater. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Anastomic urethroplasty in bulbar urethral stricture. 13 years experience in a department of urology.

    PubMed

    Sáez-Barranquero, F; Herrera-Imbroda, B; Yáñez-Gálvez, A; Sánchez-Soler, N; Castillo-Gallardo, E; Cantero-Mellado, J A; Julve-Villalta, E; Machuca-Santa Cruz, F J

    2016-01-01

    Urethral stenosis is a common disease in the clinical practice of urology, with a major impact on the quality of life of patients. The anastomotic urethroplasty is a technique with very precise indications usually membranous or bulbar urethra stenosis with a length of 3 cm or up to 7 cm when it is secondary to urethral disruptions (no stenosis) after pelvic trauma. We review anastomotic urethroplasty performed in our department between 2002 and 2015. A retrospective, descriptive and inferential analysis on 107 patients out of 482 treated with Anastomotic urethroplasty by urethral strictures at the Urology Department of the Hospital "Virgen de la Victoria" (Malaga) from January 2002 to September 2015, establishing effectiveness and safety of the technique, as well as factors that might influence the results. The main diagnostic method was retrograde urethrography and voiding cystourethrography in 100% of patients undergoing surgery, using voiding uroflowmetry for subsequent monitoring. The definition of success was a postoperative flowmetry with Qmax>15 ml/s, and in case of lower flow, we perform a cystoscopy to verify recurrence of stenosis or exclude other pathology. The median age was 42 years, with a mean follow up of 59 months. The length of stenosis valued by retrograde urethrography and voiding cystourethrography was in 91.6% of cases of >1 cm and <2 cm. The most common etiology was idiopathic in 72.9%, followed by iatrogenic with 15.9%. Regarding the location, it was observed that the area most often affected was the bulbar urethra with 82.2%, with the membranous urethra in second place. In 77.6% of patients anastomotic urethroplasty was the initial treatment, followed in frequency by direct vision internal urethrotomy 9.3%. In the case of comorbidities associated with treatment with anastomotic urethroplasty it was observed that only Diabetes Mellitus had a tendency to statistical significance, with p=0.092, not demonstrating such significance in the case of hypertension or when the subject presented Diabetes Mellitus together with hypertension. Finally, the intervention was successful in 102 cases (95.3%), with only 5 cases (4.7%) where it failed, 4 of them treated with a new Anastomotic urethroplasty, with resolution of the stricture. Anastomotic urethroplasty is the treatment of choice for short bulbar urethral stricture, with high success rate and low complication rate, as well as low recurrence of these.

  19. [Expressions of interleukin-17 and interleukin-8 in the prostatic tissue of the patients with BPH or BPH with inflammation].

    PubMed

    Gao, Rui; Liu, Qi-Xiang; Zhou, Hui-Liang; Cao, Lin-Sheng; Jiang, Tao; Tang, Song-Xi; Ding, Yi-Lang

    2017-08-01

    To investigate the expressions of interleukin-17 (IL-17) and interleukin-8 (IL-8) in benign prostatic hyperplasia (BPH) and BPH complicated with histological inflammation and their significance. According to the results of HE staining, we divided 60 cases of BPH treated by transurethral resection of the prostate (TURP) into a BPH group (n = 23) and a BPH with inflammation group (n = 37). We analyzed the clinical data of the patients and determined the mRNA and protein expressions of IL-17 and IL-8 by immunohistochemistry, real-time fluorescence quantitative PCR, and Western blot, respectively. Compared with the BPH patients complicated with inflammation, the BPH group showed significantly lower International Prostate Symptom Score (IPSS) (29.1 ± 6.2 vs 21.6 ± 3.7), quality of life score (QoL) (5.4 ± 1.3 vs 4.4 ± 1.6), postvoid residual urine volume (RUV) ([198.6 ± 15.5] vs [98.2 ± 19.3] ml), prostate volume ([69.2 ± 24.1] vs [49.8 ± 16.5] ml), PSA level ([7.4 ± 1.9] vs [2.8 ± 0.8] μg/L) and serum c-reactive protein content (CRP) ([5.1±2.0] vs [1.5±0.6] mg/L), but a higher maximum urine flow rate (Qmax) ([4.7 ± 2.1] vs [8.2 ± 1.8] ml/s) (all P<0.05). The former group had a significantly higher incidence rate of urinary retention than the latter (32.4% [12/37] vs 8.69% [2/23]), mRNA expressions of IL-17 (0.303 ± 0.076 vs 0.042 ± 0.019) and IL-8 (0.536 ± 0.059 vs 0.108 ± 0.025), and protein expressions of IL-17 (0.88 ± 0.10 vs 0.34 ± 0.05) and IL-8 (1.07 ± 0.08 vs 0.43 ± 0.04) (all P<0.05). The expressions of IL-17 and IL-8 are upregulated in the prostatic tissue of the BPH patients with inflammation, which may play a significant role in the development and progression of BPH.

  20. Urethroplasty after Urethral Urolume Stent: an International Multicenter Experience.

    PubMed

    Angulo, Javier C; Kulkarni, Sanjay; Pankaj, Joshi; Nikolavsky, Dmitriy; Suarez, Pedro; Belinky, Javier; Virasoro, Ramón; DeLong, Jessica; Martins, Francisco E; Lumen, Nicolaas; Giudice, Carlos; Suárez, Oscar A; Menéndez, Nicolás; Capiel, Leandro; López-Alvarado, Damian; Ramirez, Erick A; Venkatesan, Krishnan; Husainat, Maha M; Esquinas, Cristina; Arance, Ignacio; Gómez, Reynaldo; Santucci, Richard

    2018-05-08

    To evaluate the outcomes and factors affecting success of urethroplasty in patients with stricture recurrence after Urolume® urethral stent. Retrospective international multicenter study on patients treated with urethral reconstruction after Urolume® stent. Stricture and stent length, time between urethral stent insertion and urethroplasty, age, mode of stent retrieval, type of urethroplasty, complications and baseline and post-urethroplasty voiding parameters were analyzed. Successful outcome was defined as standard voiding, without need of any postoperative adjunctive procedure. Sixty-three patients were included. Stent was removed at urethroplasty in 61 patients. Reconstruction technique was excision and primary anastomosis in 14(22.2%), dorsal onlay buccal mucosa graft (BMG) 9(14.3%), ventral onlay BMG 6(9.5%), dorso-lateral onlay BMG 9(14.3%), ventral onlay plus dorsal inlay BMG 3(4.8%), augmented anastomosis 5(7.9%), pedicled flap urethroplasty 6(9.5%), 2-stage procedure 4(6.4%) and perineal urethrostomy 7(11.1%). Success rate was 81% at a mean 59.7+63.4months. Dilatation and/or internal urethrotomy was performed in 10(15.9%), redo-urethroplasty in 5(7.9%). Total IPSS, QoL, Qmax and PVR significantly improved (p<.0001). Complications occurred in 8(12.7%), all Clavien-Dindo <2. Disease-free survival rate after reconstruction was 88.1%,79.5% and 76.7% at 1,3 and 5-years respectively. Explant of individual strands followed by onlay BMG is the most common approach and was significantly advantageous over the other techniques (p=.018). Urethroplasty in patients with Urolume® urethral stents is a viable option of reconstruction with a high success rate and very acceptable complication rate. Numerous techniques are viable, however, urethral preservation, tine-by-tine stent extraction and use of BMG augmentation produced significantly better outcomes. Copyright © 2018 Elsevier Inc. All rights reserved.

  1. Thorium binding by biochar fibres derived from Luffa Cylindrica after controlled surface oxidation

    NASA Astrophysics Data System (ADS)

    Liatsou, Ioanna; Christodoulou, Eleni; Paschalidis, Ioannis

    2017-04-01

    Controlled surface modification of biochar fibres derived from Luffa Cylindrica sponges has been carried out by nitric acid and the degree of oxidation could be controlled by changing the acid concentration or the reaction time. The extent of surface oxidation has been quantified by acid-base titration and FTIR-spectroscopy. Furthermore, thorium binding has been studied as a function of various parameters and the experimental results show that even under strong acidic conditions the relative sorption is above 70% and the sorption capacity of the biochar fibres for Th(IV) at pH 3 is qmax= 70 gṡkg-1.

  2. Concomitant semi-quantitative and visual analysis improves the predictive value on treatment outcome of interim 18F-fluorodeoxyglucose / Positron Emission Tomography in advanced Hodgkin lymphoma.

    PubMed

    Biggi, Alberto; Bergesio, Fabrizio; Chauvie, Stephane; Bianchi, Andrea; Menga, Massimo; Fallanca, Federico; Hutchings, Martin; Gregianin, Michele; Meignan, Michel; Gallamini, Andrea

    2017-07-27

    Qualitative assessment using the Deauville five-point scale (DS) is the gold standard for interim and end-of treatment PET interpretation in lymphoma. In the present study we assessed the reliability and the prognostic value of different semi- quantitative (SQ) parameters in comparison with DS for interim PET (iPET) interpretation in Hodgkin lymphoma (HL). A cohort of 82 out of 260 patients with advanced stage HL enrolled in the International Validation Study (IVS), scored as 3 to 5 by the expert panel was included in the present report. Two nuclear medicine physicians blinded to patient history, clinical data and treatment outcome reviewed independently the iPET using the following parameters: DS, SUVMax, SUVPeak of the most active lesion, QMax (ratio of SUVMax of the lesion to liver SUVMax) and QRes (ratio of SUVPeak of the lesion to liver SUVMean). The optimal sensitivity, specificity, positive and negative predictive value to predict treatment outcome was calculated for all the above parameters with the Receiver Operator Characteristics analysis. The prognostic value of all parameters were similar, the best cut-off value being 4 for DS (Area Under the Curve, AUC, 0.81 CI95%: 0.72-0.90), 3.81 for SUVMax (AUC 0.82 CI95%: 0.73-0.91), 3.20 for SUVPeak (AUC 0.86 CI95%: 0.77-0.94), 1.07 for QMax (AUC 0.84 CI95%: 0.75-0.93) and 1.38 for QRes (AUC 0.84 CI95%: 0.75-0.93). The reproducibility of different parameters was similar as the inter-observer variability measured with Cohen's kappa were 0.93 (95% CI 0.84-1.01) for the DS, 0.88 (0.77-0.98) for SUVMax, 0.82 (0.70-0.95) for SUVPeak, 0.85 (0.74-0.97) for QRes and 0.78 (0.65-0.92) for QMax. Due to the high specificity of SUVPeak (0.87) and to the good sensitivity of DS (0.86), upon the use of both parameters the positive predictive value increased from 0.65 of the DS alone to 0.79. When both parameters were positive in iPET, 3-years Failure-Free Survival (FFS) was significantly lower compared to patients whose iPET was interpreted with qualitative parameters only (DS 4 or 5): 21% vs 35%. On the other hand, the FFS of patients with negative results was not significantly different (88% vs 86%). In this study we demonstrated that, combining semi-quantitative parameters with SUVPeak to a pure qualitative interpretation key with DS, it is possible to increase the positive predictive value of iPET and to identify with higher precision the patients subset with a very dismal prognosis. However, these retrospective findings should be confirmed prospectively in a larger patient cohort.

  3. Profile of lower urinary tract symptoms in the male and their impact on quality of life.

    PubMed

    Cambronero, J; Arlandis, S; Errando, C; Mora, A M

    2013-01-01

    Following current European Guidelines, Lower Urinary Tract Symptoms (LUTS) are produced by several causes and, thus, thorough clinical assessment should be undertaken for a correct therapeutic management. This study was conducted in order to assess the symptoms profile and their impact on Health-Related Quality of Life (HRQL) of male patients attending urology outpatient clinics. Epidemiological, cross-sectional study including adult male patients (n=826) presenting with at least one de novo previously untreated LUTS. Socio-demographic and clinical variables were collected. Patients completed IPSS, Bladder Control Self-Assessment Questionnaire (B-SAQ) and SF-12 questionnaires. Mean age (SD) was 65 (10) years. A combination of storage, voiding and post-micturition symptoms were present in 69% of subjects and 30% showed >2 urgency episodes and >6 micturitions daily (storage symptoms -SS- sub-population). Storage symptoms were the reason for consultation in 86%. Mean peak urinary flow (Q(max)) was 11.4 mL/s, in 44% of patients,prostate volume was 20-40 mL and 91% showed moderate or severe symptoms on IPSS with an overall mean (SD) score of 17 (7). SS sub-population had higher B-SAQ scores (6,9 vs 4,8 for symptoms; 7,8 vs 5,1 for bother), and worse HRQL (IPSS item 8). These findings support the importance of addressing treatment adequately according to patient profile, bothersomeness and impact on HRQL. Copyright © 2012 AEU. Published by Elsevier Espana. All rights reserved.

  4. Urodynamic changes associated with successful stress urinary incontinence surgery: is a little tension a good thing?

    PubMed

    Kraus, Stephen R; Lemack, Gary E; Sirls, Larry T; Chai, Toby C; Brubaker, Linda; Albo, Michael; Leng, Wendy W; Lloyd, L Keith; Norton, Peggy; Litman, Heather J

    2011-12-01

    To identify urodynamic changes that correlate with successful outcomes after stress urinary incontinence (SUI) surgery. Six-hundred fifty-five women were randomized to Burch colposuspension or autologous fascial sling as part of the multicenter Stress Incontinence Surgical Treatment Efficacy Trial. Preoperatively and 24 months after surgery, participants underwent standardized urodynamic testing that included noninvasive uroflowmetry, cystometrogram, and pressure flow studies. Changes in urodynamic parameters were correlated to a successful outcome, defined a priori as (1) negative pad test; (2) no urinary incontinence on 3-day diary; (3) negative cough and Valsalva stress test; (4) no self-reported SUI symptoms on the Medical, Epidemiologic and Social Aspects of Aging Questionnaire; and (5) no re-treatment for SUI. Subjects who met criteria for surgical success showed a greater relative increase in mean Pdet@Qmax (baseline vs 24 months) than women who were considered surgical failures (P = .008). Although a trend suggested an association between greater increases in bladder outlet obstruction index and outcome success, this was not statistically significant. Other urodynamic variables, such as maximum uroflow, bladder compliance, and the presence of preoperative or de novo detrusor overactivity did not differ with respect to outcome status. Successful outcomes in both surgical groups (Burch and sling) were associated with higher voiding pressures relative to preoperative baseline values. However, concomitant changes in other urodynamic voiding parameters were not significantly associated with outcome. Copyright © 2011 Elsevier Inc. All rights reserved.

  5. Phase 1 and 2 studies demonstrate the safety and efficacy of intraprostatic injection of PRX302 for the targeted treatment of lower urinary tract symptoms secondary to benign prostatic hyperplasia.

    PubMed

    Denmeade, Samuel R; Egerdie, Blair; Steinhoff, Gary; Merchant, Rosemina; Abi-Habib, Ralph; Pommerville, Peter

    2011-05-01

    PRX302 is a prostate specific antigen (PSA)-activated pore-forming protein toxin under development as a targeted approach for improving lower urinary tract symptoms (LUTS) caused by benign prostatic hyperplasia (BPH) without affecting sexual function. To evaluate the safety and efficacy of PRX302 in men with moderate to severe BPH. Eligible subjects were refractory, intolerant, or unwilling to undergo medical therapies for BPH and had International Prostate Symptom Score (IPSS) ≥12, a quality of life (QoL) score ≥3, and prostate volumes between 30 and 80 g. Fifteen patients were enrolled in phase 1 studies, and 18 patients entered phase 2 studies. Subjects received intraprostatic injection of PRX302 into the right and left transition zone via a transperineal approach in an office-based setting. Phase 1 subjects received increasing concentrations of PRX302 at a fixed volume; phase 2 subjects received increasing volumes per deposit at a fixed concentration. IPSS, QoL, prostate volume, maximum flow rate (Q(max)), International Index of Erectile Function, serum PSA levels, pharmacokinetics, and adverse events were recorded at 30, 60, 90, 180, 270, and 360 d after treatment with PRX302. Sixty percent of men in the phase 1 study and 64% of men in the phase 2 study treated with PRX302 had ≥30% improvement compared to baseline in IPSS out to day 360. Patients also experienced improvement in QoL and reduction in prostate volume out to day 360. Patients receiving ≥1 ml of PRX302 per deposit had the best response overall. PRX302 had no deleterious effect on erectile function. Adverse events were mild to moderate and transient in nature. The major study limitation was the small sample size. The promising safety profile and evidence of efficacy in the majority of treated subjects in these phase 1 and 2 studies supports further development of PRX302 as a minimally invasive, targeted treatment for BPH. Copyright © 2010 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  6. Bipolar plasma vaporization using plasma-cutting and plasma-loop electrodes versus cold-knife transurethral incision for the treatment of posterior urethral stricture: a prospective, randomized study.

    PubMed

    Cai, Wansong; Chen, Zhiyuan; Wen, Liping; Jiang, Xiangxin; Liu, Xiuheng

    2016-01-01

    Evaluate the efficiency and safety of bipolar plasma vaporization using plasma-cutting and plasma-loop electrodes for the treatment of posterior urethral stricture. Compare the outcomes following bipolar plasma vaporization with conventional cold-knife urethrotomy. A randomized trial was performed to compare patient outcomes from the bipolar and cold-knife groups. All patients were assessed at 6 and 12 months postoperatively via urethrography and uroflowmetry. At the end of the first postoperative year, ureteroscopy was performed to evaluate the efficacy of the procedure. The mean follow-up time was 13.9 months (range: 12 to 21 months). If re-stenosis was not identified by both urethrography and ureteroscopy, the procedure was considered "successful". Fifty-three male patients with posterior urethral strictures were selected and randomly divided into two groups: bipolar group (n=27) or cold-knife group (n=26). Patients in the bipolar group experienced a shorter operative time compared to the cold-knife group (23.45±7.64 hours vs 33.45±5.45 hours, respectively). The 12-month postoperative Qmax was faster in the bipolar group than in the cold-knife group (15.54±2.78 ml/sec vs 18.25±2.12 ml/sec, respectively). In the bipolar group, the recurrence-free rate was 81.5% at a mean follow-up time of 13.9 months. In the cold-knife group, the recurrence-free rate was 53.8%. The application of bipolar plasma-cutting and plasma-loop electrodes for the management of urethral stricture disease is a safe and reliable method that minimizes the morbidity of urethral stricture resection. The advantages include a lower recurrence rate and shorter operative time compared to the cold-knife technique.

  7. Using transurethral Ho:YAG-laser resection to treat urethral stricture and bladder neck contracture

    NASA Astrophysics Data System (ADS)

    Bo, Juanjie; Dai, Shengguo; Huang, Xuyuan; Zhu, Jing; Zhang, Huiguo; Shi, Hongmin

    2005-07-01

    Objective: Ho:YAG laser had been used to treat the common diseases of urinary system such as bladder cancer and benign prostatic hyperplasia in our hospital. This study is to assess the efficacy and safety of transurethral Ho:YAG-laser resection to treat the urethral stricture and bladder neck contracture. Methods: From May 1997 to August 2004, 26 cases of urethral stricture and 33 cases of bladder neck contracture were treated by transurethral Ho:YAG-laser resection. These patients were followed up at regular intervals after operation. The uroflow rate of these patients was detected before and one-month after operation. The blood loss and the energy consumption of holmium-laser during the operation as well as the complications and curative effect after operation were observed. Results: The therapeutic effects were considered successful, with less bleeding and no severe complications. The Qmax of one month postoperation increased obviously than that of preoperation. Of the 59 cases, restenosis appeared in 11 cases (19%) with the symptoms of dysuria and weak urinary stream in 3-24 months respectively. Conclusions: The Ho:YAG-laser demonstrated good effect to treat the obstructive diseases of lower urinary tract such as urethral stricture and bladder neck contracture. It was safe, minimal invasive and easy to operate.

  8. Novel degradation pathway and kinetic analysis for buprofezin removal by newly isolated Bacillus sp.

    PubMed

    Wang, Guangli; Xu, Dayong; Xiong, Minghua; Zhang, Hui; Li, Feng; Liu, Yuan

    2016-09-15

    Given the intensive and widespread application of the pesticide, buprofezin, its environmental residues potentially pose a problem; yet little is known about buprofezin's kinetic and metabolic behaviors. In this study, a novel gram-positive strain, designated BF-5, isolated from aerobic activated sludge, was found to be capable of metabolizing buprofezin as its sole energy, carbon, and nitrogen source. Based on its physiological and biochemical characteristics, other aspects of its phenotype, and a phylogenetic analysis, strain BF-5 was identified as Bacillus sp. This study investigated the effect of culture conditions on bacterial growth and substrate degradation, such as pH, temperature, initial concentration, different nitrogen source, and additional nitrogen sources as co-substrates. The degradation rate parameters, qmax, Ks, Ki and Sm were determined to be 0.6918 h(-1), 105.4 mg L(-1), 210.5 mg L(-1), and 148.95 mg L(-1) respectively. The capture of unpublished potential metabolites by gas chromatography-mass spectrometry (GC-MS) analysis has led to the proposal of a novel degradation pathway. Taken together, our results clarify buprofezin's biodegradation pathway(s) and highlight the promising potential of strain BF-5 in bioremediation of buprofezin-contaminated environments. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. [Comparison of new portable home electronic uroflowmeter with Laborie uroflowmeter].

    PubMed

    Guan, Zhi-chen; Deng, Xiao-lin; Zhang, Qian

    2011-08-18

    To design a new portable home electronic uroflowmeter and compare it with traditional methods. The system consists of collectors, urine conducting apparatus, intelligent cell phone, wireless network communication technology, computer analysis and drawing, and data storage technology, etc., and can automatically collect voiding information from patients with lower urinary tract symptoms(LUTS) Through Bluetooth, the voiding information was sent to the patient's intelligent cell phone from the collector, then stored directly by intelligent cell phone and wirelessly transmitted to the workstation in hospital. The system was primarily tested with regard to accuracy of measurement of the voided volume. Multiple doses with known volume were introduced in the system and Laborie uroflowmeter. Furthermore, 38 outpatients who had LUTS were tested simultaneously with the system and Laborie uroflowmeter. The statistical method for assessing agreement between the two methods of clinical measurement was Bland-Altman analysis. Among the subjects, there were 22 male patients and 16 female patients, ranging from 21 to 37 years old, with an average age of 25.5 years, of whom, 19 were tested once and 19 patients twice, equaling to 57 tests. The system could accurately collect and analyze voiding time, uroflowmetry, voided volume, and automatically provide uroflowmetry parameters. The measurement error of 100, 200, 300, 500 and 800 mL is less than 5%. 12.28%, 5.26% and 3.51% of the Qmax, Qave and voided volume points were beyond the 95% limits of agreement. The maximum absolute values of the Qmax, Qave and voided volume difference were 0.38 mL/s, 0.70 mL/s and 2.90 mL, respectively.They agreed with the recommendation of Standardization International Continence Society. The new portable home electronic uroflowmeter has good agreement with Laborie uroflowmeter,and is a new LUTS monitoring system integrated with correct, reliable, real-time, convenient and easy-managing advantages. It is as noninvasive and reliable as traditional methods, and its portable feature facilitates application out of hospitals. It can also record voiding diaries.

  10. Prostatic Arterial Embolization Treating Moderate-to-Severe Lower Urinary Tract Symptoms Related to Benign Prostate Hyperplasia: A Meta-Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Feng, Shijian; Tian, Ye; Liu, Wei

    PurposeTo evaluate the clinical efficiency and safety of PAE treating moderate-to-severe LUTS related to BPH.Materials and MethodsA systematic literature search was performed using PUBMED, EMBASE, Cochrane database of systematic review, and Web of Science, up to April 2016, to identify eligible studies. The Cochrane Collaboration’s RevMan 5.3 was used to analyze the extracted data. Random- or fixed-effect model was selected to fit the pooled out heterogeneity.Results20 eligible studies were included in this meta-analysis. Synthetic data showed that there were statistically significant improvements in IPSS (MD = −13.25; 95% CI −14.81 to −11.69; P < 0.00001), QoL score (MD = −2.34; 95% CI −2.69 to −2.00, P < 0.00001),more » PSA level (MD = −1.33; 95% CI −1.86 to −0.80; P < 0.00001), PV (MD = −28.00; 95% CI −35.94 to −20.07; P < 0.00001), Qmax (MD = 5.51; 95% CI 4.62 to 6.40; P < 0.00001), and PVR (MD = −67.8; 95% CI −81.35 to −53.60; P < 0.00001). There was no significant difference in IIEF score (MD = 0.93; 95% CI 0.43–1.42; P = 0.07). Major complications following PAE include pain in the perineum, retropubic area, and/or urethra (9.4%), and hematuria (9.0%).ConclusionsPAE should be considered to be the very promising alternative treatment for those who do not want or cannot tolerate surgical treatment, with its benefits on IPSS, QoL score, PSA level, PV, Qmax, and PVR without affecting erectile function.« less

  11. In vitro-in vivo correlation study for the dermatopharmacokinetics of terbinafine hydrochloride topical cream.

    PubMed

    Saeheng, Suwadee; Nosoongnoen, Wichit; Varothai, Supenya; Sathirakul, Korbtham

    2013-09-01

    To investigate the relationship between dermatopharmacokinetic (DPK) tape stripping from in vitro and in vivo using 1% terbinafine hydrochloride topical cream as the model formulation. In vitro and in vivo tape strippings were conducted on separated pig ear skin used as a biological membrane for franz diffusion cell testing and the non-hairy skin area at the ventral forearms of healthy volunteers, respectively. Terbinafine (1%) topical cream was applied to the skin for 0.5, 2, and 4 h. The drug profiles of terbinafine across the stratum corneum were determined immediately (time 0 h), and at 0.5, 1, 2, and 4 h after removing the formulation. The amounts of terbinafine were analyzed by a validated high-performance liquid chromatography-ultraviolet method. The area under the curve (AUC) and the maximum amounts of terbinafine absorption (Q(max)) were obtained from pharmacokinetic software. Partition coefficient (K(SC/veh)) and diffusion parameter (D/L²) were derived from the Fick's second law equation. During the schedule time of 8 h, the deviations of in vitro and in vivo data were 6.61 and 30.46% for AUC and Q(max), respectively. There was insignificant difference of the K(SC/veh) and the D/L² between excised pig ear and human skin. In addition, K(SC/veh) and D/L² at T(max) of 2 h were used to predict the AUC presented the value of 4.7481 %h whereas the true value calculated from pharmacokinetic software provided the value of 5.9311 %h differing from each other in approximate of 20%. In vitro tape stripping using the separated pig ear skin as a viable membrane of the franz diffusion cell testing demonstrates the potential to represent in vivo tape stripping in human for topical bioavailability/bioequivalence study of terbinafine hydrochloride 1% topical cream.

  12. Finding modules and hierarchy in weighted financial network using transfer entropy

    NASA Astrophysics Data System (ADS)

    Yook, Soon-Hyung; Chae, Huiseung; Kim, Jinho; Kim, Yup

    2016-04-01

    We study the modular structure of financial network based on the transfer entropy (TE). From the comparison with the obtained modular structure using the cross-correlation (CC), we find that TE and CC both provide well organized modular structure and the hierarchical relationship between each industrial group when the time scale of the measurement is less than one month. However, when the time scale of the measurement becomes larger than one month, we find that the modular structure from CC cannot correctly reflect the known industrial classification and their hierarchy. In addition the measured maximum modularity, Qmax, for TE is always larger than that for CC, which indicates that TE is a better weight measure than CC for the system with asymmetric relationship.

  13. Impact of 1/8 degree to 1/64 degree Resolution on Gulf Stream Model-Data Comparisons in Basin-Scale Subtropical Atlantic Ocean Models

    DTIC Science & Technology

    2000-01-01

    Momentum Fluxes. NOAA Atlas NESDIS 8 vol. 3 US Department of Commerce, NOAA, NESDIS, 413 p. Dietrich, G., Kalle , K ., Krauss, K ., Siedler, G., 1980...depth, hydrodynamic model are given below for layers ks1 . . . n with ks1 for the top layer. In places where k is used to index model interfaces, ks0 is...the surface and ksn is the bottom. EU 1 E U u E V u cosuŽ . Ž . k k k k k q q yV u sinuqaV sin2uŽ . k k Et acosu Ef Eu sqmax 0,yv u qmax 0,v u y max 0

  14. Fenpropathrin biodegradation pathway in Bacillus sp. DG-02 and its potential for bioremediation of pyrethroid-contaminated soils.

    PubMed

    Chen, Shaohua; Chang, Changqing; Deng, Yinyue; An, Shuwen; Dong, Yi Hu; Zhou, Jianuan; Hu, Meiying; Zhong, Guohua; Zhang, Lian-Hui

    2014-03-12

    The widely used insecticide fenpropathrin in agriculture has become a public concern because of its heavy environmental contamination and toxic effects on mammals, yet little is known about the kinetic and metabolic behaviors of this pesticide. This study reports the degradation kinetics and metabolic pathway of fenpropathrin in Bacillus sp. DG-02, previously isolated from the pyrethroid-manufacturing wastewater treatment system. Up to 93.3% of 50 mg L(-1) fenpropathrin was degraded by Bacillus sp. DG-02 within 72 h, and the degradation rate parameters qmax, Ks, and Ki were determined to be 0.05 h(-1), 9.0 mg L(-1), and 694.8 mg L(-1), respectively. Analysis of the degradation products by gas chromatography-mass spectrometry led to identification of seven metabolites of fenpropathrin, which suggest that fenpropathrin could be degraded first by cleavage of its carboxylester linkage and diaryl bond, followed by degradation of the aromatic ring and subsequent metabolism. In addition to degradation of fenpropathrin, this strain was also found to be capable of degrading a wide range of synthetic pyrethroids including deltamethrin, λ-cyhalothrin, β-cypermethrin, β-cyfluthrin, bifenthrin, and permethrin, which are also widely used insecticides with environmental contamination problems with the degradation process following the first-order kinetic model. Bioaugmentation of fenpropathrin-contaminated soils with strain DG-02 significantly enhanced the disappearance rate of fenpropathrin, and its half-life was sharply reduced in the soils. Taken together, these results depict the biodegradation mechanisms of fenpropathrin and also highlight the promising potentials of Bacillus sp. DG-02 in bioremediation of pyrethroid-contaminated soils.

  15. 40 CFR 1065.545 - Validation of proportional flow control for batch sampling.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... of the estimate, SEE, of the sample flow rate versus the total flow rate. For each test interval, demonstrate that SEE was less than or equal to 3.5% of the mean sample flow rate. (b) For any pair of flow meters, use recorded sample and total flow rates, where total flow rate means the raw exhaust flow rate...

  16. The surface characteristics of hyperbranched polyamide modified corncob and its adsorption property for Cr(VI)

    NASA Astrophysics Data System (ADS)

    Lin, Hai; Han, Shaoke; Dong, Yingbo; He, Yinhai

    2017-08-01

    A low-cost anion adsorbent for Cr(VI) effectively removing was synthesized by hyperbranched polyamide modified corncob (HPMC). Samples were characterized by Brunauer-Emmett-Teller (BET) surface area analysis, field-emission scanning electron microscopy (FE-SEM) with energy-dispersive X-ray spectroscopy, Fourier transform infrared (FTIR) and zeta potential analysis. Kinetics, isotherms and thermodynamics studies of HPMC for Cr(VI) adsorption were investigated in batch static experiments, in the temperature range of 25-45 °C, pH = 2.0. Results showed that the adsorption was rapid and stable, with the uptake capacity higher than 80% after 30 min. Adsorption behavior and rate-controlling mechanisms were analyzed using three kinetic models (pseudo-first order, pseudo-second order, intra-particle kinetic model). Kinetic studies showed that the adsorption of HPMC to Cr(VI) relied the pseudo-second-order model, and controlled both by the intra-particle diffusion and film diffusion. Equilibrium data was tested by Langmuir and Freundlich adsorption isotherm models. Langmuir model was more suitable to indicate a homogeneous distribution of active sites on HPMC and monolayer adsorption. The maximum adsorption capacity from the Langmuir model, qmax, was 131.6 mg/g at pH 2.0 and 45 °C for HPMC. Thermodynamic parameters revealed spontaneous and endothermic nature of the Cr(VI) adsorption onto HPMC.

  17. Biochar from malt spent rootlets for the removal of mercury from aqueous solutions

    NASA Astrophysics Data System (ADS)

    Boutsika, Lamprini; Manariotis, Ioannis; Karapanagioti, Hrissi K.

    2013-04-01

    Biochar is receiving increased attention as a promising material in environmental applications. It is obtained from the incomplete combustion of carbon-rich biomass under oxygen-limited conditions. One of the many proposed applications of biochars is the removal of metals (e.g., lead, mercury, etc.) from aqueous solutions. Mercury is one of the heavy metals of particular concern due to its toxicity even at relatively low concentration and thus, its removal from aqueous systems is desirable. Malt spent rootlets is a by-product formed during beer production, it is inexpensive and it is produced in high quantities. The objective of the present study was to evaluate the potential use of biochar, produced from malt spent rootlets, to remove mercury from aqueous solutions. Batch experiments were conducted at room temperature (25oC) to obtain the optimum sorption conditions under different pH values, biomass dose, contact time, and solution ionic strength. Sorption kinetics and equilibrium capacity constants were determined at the optimum pH value. Furthermore, the effect of different leaching solutions on mercury desorption from the biochar was examined. All studies with mercury and biochar were conducted at pH 5 that was determined to be the optimum pH for sorption. The proportion of mercury removal increased with the increased dose of the biochar, i.e. from 71% removal for biochar dose of 0.3 g/L, it reached almost 100% removal for biochar dose ˜1 g/L. Based on the isotherm data, the maximum biochar sorption capacity (qmax) for mercury was 99 mg/g. Based on the sorption kinetic data, (qmax) was achieved after 2 h; it should be mentioned that 30% of the (qmax) was observed within the first 5 min. Five leaching solutions were tested for mercury desorption (H2O, HCl, EDTA, NaCl and HNO3). HCl resulted in the highest extraction percentage of the sorbed mercury. The desorbing mercury percentages at 24 h for HCl concentrations 0.1, 0.2, 0.4, 0.8, and 2 M were 62, 59, 62, 69, and 95%, respectively. Finally, the influence of solution salinity in mercury sorption onto biochar was tested by adjusting the solution ionic strength with two different salts, NaCl and NaNO3. The salts were added at concentrations 1, 0.5, 0.1, 0.01, 0.001, and 0.0001 mol/L. Mercury removal was not affected by the presence of NaNO3 and high metal removal percentages were obtained even at high NaNO3 concentrations (about 53% at concentration 1 mol/L NaNO3). However, a significant decrease of mercury adsorption was observed with the increase of NaCl concentration, i.e. from 55% removal at concentration 0.0001 mol/LNaCl, it reached 20% removal at a concentration of 1 mol/L NaCl. These differences can be related to the different counter ion present in the salts. NO3- does not interfere in mercury sorption but Cl- forms mercury species with negative charge, which do not favor the sorption process. Generally, biochar from malt spent rootlets seemed as a promising novel sorbent that could be used for aqueous system remediation under most environmental conditions.

  18. In vivo study of flow-rate accuracy of the MedStream Programmable Infusion System.

    PubMed

    Venugopalan, Ramakrishna; Ginggen, Alec; Bork, Toralf; Anderson, William; Buffen, Elaine

    2011-01-01

      Flow-rate accuracy and precision are important parameters to optimizing the efficacy of programmable intrathecal (IT) infusion pump delivery systems. Current programmable IT pumps are accurate within ±14.5% of their programmed infusion rate when assessed under ideal environmental conditions and specific flow-rate settings in vitro. We assessed the flow-rate accuracy of a novel programmable pump system across its entire flow-rate range under typical conditions in sheep (in vivo) and nominal conditions in vitro.   The flow-rate accuracy of the MedStream Programmable Pump was assessed in both the in vivo and in vitro settings. In vivo flow-rate accuracy was assessed in 16 sheep at various flow-rates (producing 90 flow intervals) more than 90 ± 3 days. Pumps were then explanted, re-sterilized and in vitro flow-rate accuracy was assessed at 37°C and 1013 mBar (80 flow intervals).   In vivo (sheep body temperatures 38.1°C-39.8°C), mean ± SD flow-rate error was 9.32% ± 9.27% and mean ± SD leak-rate was 0.028 ± 0.08 mL/day. Following explantation, mean in vitro flow-rate error and leak-rate were -1.05% ± 2.55% and 0.003 ± 0.004 mL/day (37°C, 1013 mBar), respectively.   The MedStream Programmable Pump demonstrated high flow-rate accuracy when tested in vivo and in vitro at normal body temperature and environmental pressure as well as when tested in vivo at variable sheep body temperature. The flow-rate accuracy of the MedStream Programmable Pump across its flow-rate range, compares favorably to the accuracy of current clinically utilized programmable IT infusion pumps reported at specific flow-rate settings and conditions. © 2011 International Neuromodulation Society.

  19. Kinetic and mechanism studies of the adsorption of lead onto waste cow bone powder (WCBP) surfaces.

    PubMed

    Cha, Jihoon; Cui, Mingcan; Jang, Min; Cho, Sang-Hyun; Moon, Deok Hyun; Khim, Jeehyeong

    2011-01-01

    This study examines the adsorption isotherms, kinetics and mechanisms of Pb²(+) sorption onto waste cow bone powder (WCBP) surfaces. The concentrations of Pb²(+) in the study range from 10 to 90 mg/L. Although the sorption data follow the Langmuir and Freundlich isotherm, a detailed examination reveals that surface sorption or complexation and co-precipitation are the most important mechanisms, along with possibly ion exchange and solid diffusion also contributing to the overall sorption process. The co-precipitation of Pb²(+) with the calcium hydroxyapatite (Ca-HAP) is implied by significant changes in Ca²(+) and PO₄³⁻ concentrations during the metal sorption processes. The Pb²(+) sorption onto the WCBP surface by metal complexation with surface functional groups such as ≡ POH. The major metal surface species are likely to be ≡ POPb(+). The sorption isotherm results indicated that Pb²(+) sorption onto the Langmuir and Freundlich constant q(max) and K( F ) is 9.52 and 8.18 mg g⁻¹, respectively. Sorption kinetics results indicated that Pb²(+) sorption onto WCBP was pseudo-second-order rate constants K₂ was 1.12 g mg⁻¹ h⁻¹. The main mechanism is adsorption or surface complexation (≡POPb(+): 61.6%), co-precipitation or ion exchange [Ca₃(.)₉₃ Pb₁(.)₀₇ (PO₄)₃ (OH): 21.4%] and other precipitation [Pb 50 mg L⁻¹ and natural pH: 17%). Sorption isotherms showed that WCBP has a much higher Pb²(+) removal rate in an aqueous solution; the greater capability of WCBP to remove aqueous Pb²(+) indicates its potential as another promising way to remediate Pb²(+)-contaminated media.

  20. Observational study: daily treatment with a new compound “tradamixina” plus serenoa repens for two months improved the lower urinary tract symptoms

    PubMed Central

    2012-01-01

    Background Lower urinary tract symptoms (LUTS) are associated with great emotional costs to individuals and substantial economic costs to society. This study seeks to evaluate the effect of a new natural compound “Tradamixina plus Serenoa Repens” in order to improve lower urinary tract symptoms. Methods 100 patients (≥45years) who had had LUTS/BPH for >6 mo at screening and with IPSS -The international Prostate symptom scores- ≥13 and maximum urinary flow rate (Qmax) ≥4 to ≤15 ml/s. were recruited. The compound “Tradamixina plus Serenoa Repens” (80 mg of Alga Ecklonia Bicyclis, 100 mg of Tribulus Terrestris and 100 mg of D-Glucosamine and N-Acetyl-D-Glucosamine plus 320 mg of Serenoa Repens) was administered daily for 2 months. At visit and after 60 days of treatment patients were evaluated by means of detailed medical urological history, clinical examination, laboratory investigations (total PSA), and instrumental examination like urolfowmetry. Efficacy measures included IPSS-International Prostate Sympto, BPH Impact Index (BII), Quality-of-Life (QoL) Index. Measures were assessed at baseline and end point (12 wk or end of therapy) and also at screening, 1 and 4 wk for IPSS, and 4 wk for BII. Statistical significance was interpreted only if the results of the preceding analysis were significant at the 0.05 level. Results After 2 months of treatment the change from baseline to week 12 relative to “Tradamixina plus Seronea Repens” in total IPSS and Qol was statistically significant. Differences from baseline in BII were statistically significant for “Tradamixina plus Seronea Repens” above all differences in BII were also significant at 4 wk (LSmean ± SE: -0.8 ± 0.2). In the distribution of subjects over the PGI-I and CGI-I response categories were significant for”Tradamixina plus Seronea Repens” (PGI-I: p = 0.001; CGI-I). We also observed a decrease of total PSA. Conclusion The daily treatment with a new compound “Tradamixina plus Serenoa Repens” for 2 months improved the male sexual function , it improved the bother symptoms which affect the patient’s quality of life , improved uroflowmetric parameters, and we also observed a decrease of serum PSA level. PMID:23173650

  1. A randomised controlled trial to determine the clinical and cost effectiveness of thulium laser transurethral vaporesection of the prostate (ThuVARP) versus transurethral resection of the prostate (TURP) in the National Health Service (NHS) - the UNBLOCS trial: a study protocol for a randomised controlled trial.

    PubMed

    Worthington, Jo; Taylor, Hilary; Abrams, Paul; Brookes, Sara T; Cotterill, Nikki; Noble, Sian M; Page, Tobias; Swami, K Satchi; Lane, J Athene; Hashim, Hashim

    2017-04-17

    Transurethral resection of the prostate (TURP) has been the standard operation for benign prostatic obstruction (BPO) for 40 years, with approximately 25,000 procedures performed annually, and has remained largely unchanged. It is generally a successful operation, but has well-documented risks for the patient. Thulium laser transurethral vaporesection of the prostate (ThuVARP) vaporises and resects the prostate using a surgical technique similar to TURP. The small amount of study data currently available suggests that ThuVARP may have certain advantages over TURP, including reduced blood loss and shorter hospital stay, earlier return to normal activities, and shorter duration of catheterisation. A multicentre, pragmatic, randomised, controlled, parallel-group trial of ThuVARP versus standard TURP in men with BPO. Four hundred and ten men suitable for prostate surgery were randomised to receive either ThuVARP or TURP at four university teaching hospitals, and three district general hospitals. The key aim of the trial is to determine whether ThuVARP is equivalent to TURP judged on both the patient-reported International Prostate Symptom Score (IPSS) and the maximum urine flow rate (Qmax) at 12 months post-surgery. The general population has an increased life expectancy. As men get older their prostates enlarge, potentially causing BPO, which often requires surgery. Therefore, as the population ages, more prostate operations are needed to relieve obstruction. There is hence sustained interest in the condition and increasing need to find safer techniques than TURP. Various laser techniques have become available but none are widely used in the NHS because of lengthy training required for surgeons or inferior performance on clinical outcomes. Promising initial evidence from one RCT shows that ThuVARP has equivalent clinical effectiveness when compared to TURP, as well as other potential advantages. As ThuVARP uses a technique similar to that used in TURP, the learning curve is short, potentially making it also very quickly generalisable. This randomised study is designed to provide the high-quality evidence, in an NHS setting, with a range of patient-reported, clinical and cost-effectiveness outcomes, which will underpin and inform future NICE guidance. ISRCTN registry, ISRCTN00788389 . Registered on 20 September 2013.

  2. Excitation-calcium release uncoupling in aged single human skeletal muscle fibers.

    PubMed

    Delbono, O; O'Rourke, K S; Ettinger, W H

    1995-12-01

    The biological mechanisms underlying decline in muscle power and fatigue with age are not completely understood. The contribution of alterations in the excitation-calcium release coupling in single muscle fibers was explored in this work. Single muscle fibers were voltage-clamped using the double Vaseline gap technique. The samples were obtained by needle biopsy of the vastus lateralis (quadriceps) from 9 young (25-35 years; 25.9 +/- 9.1; 5 female and 4 male) and 11 old subjects (65-75 years; 70.5 +/- 2.3; 6 f, 5 m). Data were obtained from 36 and 39 fibers from young and old subjects, respectively. Subjects included in this study had similar physical activity. Denervated and slow-twitch muscle fibers were excluded from this study. A significant reduction of maximum charge movement (Qmax) and DHP-sensitive Ca current were recorded in muscle fibers from the 65-75 group. Qmax values were 7.6 +/- 0.9 and 3.2 +/- 0.3 nC/muF for young and old muscle fibers, respectively (P < 0.01). No evidences of charge inactivation or interconversion (charge 1 to charge 2) were found. The peak Ca current was (-)4.7 +/- 0.08 and (-)2.15 +/- 0.11 muA/muF for young and old fibers, respectively (P < 0.01). The peak calcium transient studied with mag-fura-2 (400 microM) was 6.3 +/- 0.4 microM and 4.2 +/- 0.3 microM for young and old muscle fibers, respectively. Caffeine (0.5 mM) induced potentiation of the peak calcium transient in both groups. The decrease in the voltage-/Ca-dependent Ca release ratio in old fibers (0.18 +/- 0.02) compared to young fibers (0.47 +/- 0.03) (P < 0.01), was recorded in the absence of sarcoplasmic reticulum calcium depletion. These data support a significant reduction of the amount of Ca available for triggering mechanical responses in aged skeletal muscle and, the reduction of Ca release is due to DHPR-ryanodine receptor uncoupling in fast-twitch fibers. These alterations can account, at least partially for the skeletal muscle function impairment associated with aging.

  3. Effect of flow rate on environmental variables and phytoplankton dynamics: results from field enclosures

    NASA Astrophysics Data System (ADS)

    Zhang, Haiping; Chen, Ruihong; Li, Feipeng; Chen, Ling

    2015-03-01

    To investigate the effects of flow rate on phytoplankton dynamics and related environment variables, a set of enclosure experiments with different flow rates were conducted in an artificial lake. We monitored nutrients, temperature, dissolved oxygen, pH, conductivity, turbidity, chlorophyll- a and phytoplankton levels. The lower biomass in all flowing enclosures showed that flow rate significantly inhibited the growth of phytoplankton. A critical flow rate occurred near 0.06 m/s, which was the lowest relative inhibitory rate. Changes in flow conditions affected algal competition for light, resulting in a dramatic shift in phytoplankton composition, from blue-green algae in still waters to green algae in flowing conditions. These findings indicate that critical flow rate can be useful in developing methods to reduce algal bloom occurrence. However, flow rate significantly enhanced the inter-relationships among environmental variables, in particular by inducing higher water turbidity and vegetative reproduction of periphyton ( Spirogyra). These changes were accompanied by a decrease in underwater light intensity, which consequently inhibited the photosynthetic intensity of phytoplankton. These results warn that a universal critical flow rate might not exist, because the effect of flow rate on phytoplankton is interlinked with many other environmental variables.

  4. Syringe Pump Performance Maintained with IV Filter Use During Low Flow Rate Delivery for Pediatric Patients.

    PubMed

    Chau, Destiny F; Vasilopoulos, Terrie; Schoepf, Miriam; Zhang, Christina; Fahy, Brenda G

    2016-09-01

    Complex surgical and critically ill pediatric patients rely on syringe infusion pumps for precise delivery of IV medications. Low flow rates and in-line IV filter use may affect drug delivery. To determine the effects of an in-line filter to remove air and/or contaminants on syringe pump performance at low flow rates, we compared the measured rates with the programmed flow rates with and without in-line IV filters. Standardized IV infusion assemblies with and without IV filters (filter and control groups) attached to a 10-mL syringe were primed and then loaded onto a syringe pump and connected to a 16-gauge, 16-cm single-lumen catheter. The catheter was suspended in a normal saline fluid column to simulate the back pressure from central venous circulation. The delivered infusate was measured by gravimetric methods at predetermined time intervals, and flow rate was calculated. Experimental trials for initial programmed rates of 1.0, 0.8, 0.6, and 0.4 mL/h were performed in control and filter groups. For each trial, the flow rate was changed to double the initial flow rate and was then returned to the initial flow rate to analyze pump performance for titration of rates often required during medication administration. These conditions (initial rate, doubling of initial rate, and return to initial rate) were analyzed separately for steady-state flow rate and time to steady state, whereas their average was used for percent deviation analysis. Differences between control and filter groups were assessed using Student t tests with adjustment for multiplicity (using n = 3 replications per group). Mean time from 0 to initial flow (startup delay) was <1 minute in both groups with no statistical difference between groups (P = 1.0). The average time to reach steady-state flow after infusion startup or rate changes was not statistically different between the groups (range, 0.8-5.5 minutes), for any flow rate or part of the trial (initial rate, doubling of initial rate, and return to initial rate), although the study was underpowered to detect small time differences. Overall, the mean steady-state flow rate for each trial was below the programmed flow rate with negative mean percent deviations for each trial. In the 1.0-mL/h initial rate trial, the steady-state flow rate attained was lower in the filter than the control group for the initial rate (P = 0.04) and doubling of initial rate (P = 0.04) with a trend during the return to initial rate (P = 0.06), although this same effect was not observed when doubling the initial rate trials of 0.8 or 0.6 mL/h or any other rate trials compared with the control group. With low flow rates used in complex surgical and pediatric critically ill patients, the addition of IV filters did not confer statistically significant changes in startup delay, flow variability, or time to reach steady-state flow of medications administered by syringe infusion pumps. The overall flow rate was lower than programmed flow rate with or without a filter.

  5. Dynamics of lava flow - Thickness growth characteristics of steady two-dimensional flow

    NASA Technical Reports Server (NTRS)

    Park, S.; Iversen, J. D.

    1984-01-01

    The thickness growth characteristics of flowing lava are investigated using a heat balance model and a two-dimensional model for flow of a Bingham plastic fluid down an inclined plane. It is found that yield strength plays a crucial role in the thickening of a lava flow of given flow rate. To illustrate this point, downstream thickness profiles and yield strength distributions were calculated for flows with mass flow rates of 10,000 and 100,000 kg/m-sec. Higher flow rates led to slow cooling rates which resulted in slow rate of increase of yield strength and thus greater flow lengths.

  6. The relation between saliva flow after different stimulations and the perception of flavor and texture attributes in custard desserts.

    PubMed

    Engelen, Lina; de Wijk, Rene A; Prinz, Jon F; van der Bilt, Andries; Bosman, Frits

    2003-01-01

    Salivary flow rates were measured at rest and after three types of stimulation; odor, Parafilm chewing, and citric acid. The highest flow rate was elicited by citric acid followed by Parafilm and odor, while the lowest flow rate was unstimulated. In order to investigate whether and how the amount of saliva a subject produces influences the sensory ratings, the four types of salivary flow rates were correlated with sensory ratings of three different types of vanilla custard dessert. No significant correlation could be found between any of the salivary flow rates and the sensory ratings. A subject with a larger saliva flow rate during eating did not rate the foods differently from a subject with less saliva flow. The same pattern was seen for all types of stimulation. This finding could indicate that subjects are used to their respective amounts of saliva to such a degree that the differences in sensory ratings between subjects cannot be explained by the interindividual difference in saliva flow rate.

  7. Experimental and analytical investigation of a freezing point depressant fluid ice protection system. M.S. Thesis. Final Report

    NASA Technical Reports Server (NTRS)

    Albright, A. E.

    1984-01-01

    A glycol-exuding porous leading edge ice protection system was tested in the NASA Icing Research Tunnel. Stainless steel mesh, laser drilled titanium, and composite panels were tested on two general aviation wing sections. Two different glycol-water solutions were evaluated. Minimum glycol flow rates required for anti-icing were obtained as a function of angle of attack, liquid water content, volume median drop diameter, temperature, and velocity. Ice accretions formed after five minutes of icing were shed in three minutes or less using a glycol fluid flow equal to the anti-ice flow rate. Two methods of predicting anti-ice flow rates are presented and compared with a large experimental data base of anti-ice flow rates over a wide range of icing conditions. The first method presented in the ADS-4 document typically predicts flow rates lower than the experimental flow rates. The second method, originally published in 1983, typically predicts flow rates up to 25 percent higher than the experimental flow rates. This method proved to be more consistent between wing-panel configurations. Significant correlation coefficients between the predicted flow rates and the experimental flow rates ranged from .867 to .947.

  8. Dialyzer clearances and mass transfer-area coefficients for small solutes at low dialysate flow rates.

    PubMed

    Leypoldt, John K; Kamerath, Craig D; Gilson, Janice F; Friederichs, Goetz

    2006-01-01

    New daily hemodialysis therapies operate at low dialysate flow rates to minimize dialysate volume requirements; however, the dependence of dialyzer clearances and mass transfer-area coefficients for small solutes on dialysate flow rate under these conditions have not been studied extensively. We evaluated in vitro dialyzer clearances for urea and creatinine at dialysate flow rates of 40, 80, 120, 160, and 200 ml/min and ultrafiltration flow rates of 0, 1, and 2 l/h, using a dialyzer containing PUREMA membranes (NxStage Medical, Lawrence, MA). Clearances were measured directly across the dialyzer by perfusing bovine blood with added urea and creatinine single pass through the dialyzer at a nominal blood flow rate of 400 ml/min. Limited, additional studies were performed with the use of dialyzers containing PUREMA membranes at a blood flow rate of 200 ml/min and also with the use of other dialyzers containing polysulfone membranes (Optiflux 160NR, FMC-NA, Ogden, UT) and dialyzers containing Synphan membranes (NxStage Medical). For dialyzers containing PUREMA membranes, urea and creatinine clearances increased (p < 0.001) with increasing dialysate and ultrafiltration flow rates but were not different at blood flow rates of 200 and 400 ml/min. Dialysate saturation, defined as dialysate outlet concentration divided by blood water inlet concentration, for urea and creatinine was independent of blood and ultrafiltration flow rate but varied inversely (p < 0.001) with dialysate flow rate. Mass transfer-area coefficients for urea and creatinine were independent of blood and ultrafiltration flow rate but decreased (p < 0.001) with decreasing dialysate flow rate. Calculated mass transfer-area coefficients at low dialysate flow rates for all dialyzers tested were substantially lower than those reported by the manufacturers under conventional conditions. We conclude that dialyzers require specific characterization under relevant conditions if they are used in novel daily hemodialysis therapies at low dialysate flow rate.

  9. Inspiratory flow rate, not type of incentive spirometry device, influences chest wall motion in healthy individuals.

    PubMed

    Chang, Angela T; Palmer, Kerry R; McNaught, Jessie; Thomas, Peter J

    2010-08-01

    This study investigated the effect of flow rates and spirometer type on chest wall motion in healthy individuals. Twenty-one healthy volunteers completed breathing trials to either two times tidal volume (2xV(T)) or inspiratory capacity (IC) at high, low, or natural flow rates, using a volume- or flow-oriented spirometer. The proportions of rib cage movement to tidal volume (%RC/V(T)), chest wall diameters, and perceived level of exertion (RPE) were compared. Low and natural flow rates resulted in significantly lower %RC/V(T) compared to high flow rate trials (p=0.001) at 2xV(T). Low flow trials also resulted in significantly less chest wall motion in the upper anteroposterior direction than high and natural flow rates (p<0.001). At IC, significantly greater movement occurred in the abdominal lateral direction during low flow compared to high and natural flow trials (both p<0.003). RPE was lower for the low flow trials compared to high flow trials at IC and 2xV(T) (p<0.01). In healthy individuals, inspiratory flow (not device type) during incentive spirometry determines the resultant breathing pattern. High flow rates result in greater chest wall motion than low flow rates.

  10. Augmentative effect of pulsatility on the wall shear stress in tube flow.

    PubMed

    Nakata, M; Tatsumi, E; Tsukiya, T; Taenaka, Y; Nishimura, T; Nishinaka, T; Takano, H; Masuzawa, T; Ohba, K

    1999-08-01

    Wall shear stress (WSS) has been considered to play an important role in the physiological and metabolic functions of the vascular endothelial cells. We investigated the effects of the pulse rate and the maximum flow rate on the WSS to clarify the influence of pulsatility. Water was perfused in a 1/2 inch transparent straight cylinder with a nonpulsatile centrifugal pump and a pulsatile pneumatic ventricular assist device (VAD). In nonpulsatile flow (NF), the flow rate was changed 1 to 6 L/min by 1 L/min increments to obtain standard values of WSS at each flow rate. In pulsatile flow (PF), the pulse rate was controlled at 40, 60, and 80 bpm, and the maximum flow rate was varied from 3.3 to 12.0 L/min while the mean flow rate was kept at 3 L/min. The WSS was estimated from the velocity profile at measuring points using the laser illuminated fluorescence method. In NF, the WSS was 12.0 dyne/cm2 at 3 L/min and 33.0 dyne/cm2 at 6 L/min. In PF, the pulse rate change with the same mean, and the maximum flow rate did not affect WSS. On the other hand, the increase in the maximum flow rate at the constant mean flow rate of 3 L/min augmented the mean WSS from 13.1 to 32.9 dyne/cm2. We concluded that the maximum flow rate exerted a substantial augmentative effect on WSS, and the maximum flow rate was a dominant factor of pulsatility in this effect.

  11. Evaluation of exhaled nitric oxide in schoolchildren at different exhalation flow rates.

    PubMed

    Pedroletti, Christophe; Zetterquist, Wilhelm; Nordvall, Lennart; Alving, Kjell

    2002-09-01

    Nitric oxide (NO) in exhaled air is believed to reflect allergic inflammation in the airways. Measured levels of exhaled NO vary with the exhaled flow rate, which therefore must be standardized. The aim of this study was to estimate the optimal exhalation flow rate when measuring NO in exhaled air. We studied 15 asthmatic children (8-18 y) with elevated NO levels and 15 age-matched controls and focused on how the quality of the NO curve profile, the discriminatory power, and the reproducibility were influenced by the exhalation flow rate. We used an on-line system for NO measurements at six different exhalation flow rates in the interval of 11-382 mL/s. The fraction of exhaled nitric oxide (FENO) was highly flow-dependent as was expected. Intermediate flow rates yielded a flat and stable NO plateau and were considerably easier to interpret than those obtained at the highest and lowest flow rates. The ratio of FENO between asthmatics and controls was lower at higher flow rates and a considerable overlap in NO values was demonstrated at all flow rates except 50 mL/s. The reproducibility was much lower at more extreme flow rates and was best at 50 mL/s. We conclude that a target exhalation flow rate of approximately 50 mL/s is to be preferred using the single-breath method for on-line NO measurements in schoolchildren.

  12. URETHROPLASTY FOR COMPLICATED ANTERIOR URETHRAL STRICTURES.

    PubMed

    Aoki, Katsuya; Hori, Shunta; Morizawa, Yosuke; Nakai, Yasushi; Miyake, Makito; Anai, Satoshi; Torimoto, Kazumasa; Yoneda, Tatsuo; Tanaka, Nobumichi; Yoshida, Katsunori; Fujimoto, Kiyohide

    2016-01-01

    (Objectives) To compare efficacy and outcome of urethroplasty for complicated anterior urethral strictures. (Methods) Twelve patients, included 3 boys, with anterior urethral stricture underwent urethroplasty after the failure of either urethral dilatation or internal urethrotomy. We evaluated pre- and post-operative Q max and surgical outcome. (Results) Four patients were treated with end-to-end anastomosis, included a case of bulbar urethral elongation simultaneously, one patient was treated with augmented anastomotic urethroplasty, three patients were treated with onlay urethroplasty with prepucial flap, one patient was treated with tubed urethroplasty with prepucial flap (Ducket procedure) and three patients were treated with onlay urethroplasty with buccal mucosal graft. Postoperative Qmax improved in all patients without major complications and recurrence during follow-up periods ranging from 17 to 102 months (mean 55 months). (Conclusions) Urethroplasty is an effective therapeutic procedure for complicated anterior urethral stricture.

  13. Milk Flow Rates from bottle nipples used after hospital discharge.

    PubMed

    Pados, Britt Frisk; Park, Jinhee; Thoyre, Suzanne M; Estrem, Hayley; Nix, W Brant

    To test the milk flow rates and variability in flow rates of bottle nipples used after hospital discharge. Twenty-six nipple types that represented 15 common brands as well as variety in price per nipple and store location sold (e.g., Babies R' Us, Walmart, Dollar Store) were chosen for testing. Ten of each nipple type (n = 260 total) were tested by measuring the amount of infant formula expressed in 1 minute using a breast pump. Mean milk flow rate (mL/min) and coefficient of variation (CV) were calculated. Flow rates of nipples within brand were compared statistically. Milk flow rates varied from 1.68 mL/min for the Avent Natural Newborn Flow to 85.34 mL/min for the Dr. Brown's Standard Y-cut. Variability between nipple types also varied widely, from .03 for the Dr. Brown's Standard Level 3 to .37 for MAM Nipple 1 Slow Flow. The extreme range of milk flow rates found may be significant for medically fragile infants being discharged home who are continuing to develop oral feeding skills. The name of the nipple does not provide clear information about the flow rate to guide parents in decision making. Variability in flow rates within nipples of the same type may complicate oral feeding for the medically fragile infant who may not be able to adapt easily to change in flow rates. Both flow rate and variability should be considered when guiding parents to a nipple choice.

  14. Unstimulated salivary flow rate, pH and buffer capacity of saliva in healthy volunteers.

    PubMed

    Fenoll-Palomares, C; Muñoz Montagud, J V; Sanchiz, V; Herreros, B; Hernández, V; Mínguez, M; Benages, A

    2004-11-01

    To assess the salivary flow rate, pH, and buffer capacity of healthy volunteers, and their relationships with age, gender, obesity, smoking, and alcohol consumption, and to establish the lower-end value of normal salivary flow (oligosialia). A prospective study was conducted in 159 healthy volunteers (age > 18 years, absence of medical conditions that could decrease salivary flow). Unstimulated whole saliva was collected during ten minutes, and salivary flow rate (ml/min), pH, and bicarbonate concentration (mmol/l) were measured using a Radiometer ABL 520. The 5 percentile of salivary flow rate and bicarbonate concentration was considered the lower limit of normality. Median salivary flow rate was 0.48 ml/min (range: 0.1-2 ml/min). Age younger than 44 years was associated with higher flow rates (OR 2.10). Compared with women, men presented a higher flow rate (OR 3.19) and buffer capacity (OR 2.81). Bicarbonate concentration correlated with salivary flow rate. The lower-end values of normal flow rate and bicarbonate concentration were 0.15 ml/min and 1.800 mmol/l, respectively. The presence of obesity, smoking, and alcohol consumption did not influence salivary parameters. In healthy volunteers, salivary flow rate depends on age and gender, and correlates with buffer capacity. Obesity, smoking, and alcohol use do not influence salivary secretion.

  15. Semiempirical method of determining flow coefficients for pitot rake mass flow rate measurements

    NASA Technical Reports Server (NTRS)

    Trefny, C. J.

    1985-01-01

    Flow coefficients applicable to area-weighted pitot rake mass flow rate measurements are presented for fully developed, turbulent flow in an annulus. A turbulent velocity profile is generated semiempirically for a given annulus hub-to-tip radius ratio and integrated numerically to determine the ideal mass flow rate. The calculated velocities at each probe location are then summed, and the flow rate as indicated by the rake is obtained. The flow coefficient to be used with the particular rake geometry is subsequently obtained by dividing the ideal flow rate by the rake-indicated flow rate. Flow coefficients ranged from 0.903 for one probe placed at a radius dividing two equal areas to 0.984 for a 10-probe area-weighted rake. Flow coefficients were not a strong function of annulus hub-to-tip radius ratio for rakes with three or more probes. The semiempirical method used to generate the turbulent velocity profiles is described in detail.

  16. Development of digital flow control system for multi-channel variable-rate sprayers

    USDA-ARS?s Scientific Manuscript database

    Precision modulation of nozzle flow rates is a critical step for variable-rate spray applications in orchards and ornamental nurseries. An automatic flow rate control system activated with microprocessors and pulse width modulation (PWM) controlled solenoid valves was developed to control flow rates...

  17. Milk flow rates from bottle nipples used after hospital discharge

    PubMed Central

    Pados, Britt Frisk; Park, Jinhee; Thoyre, Suzanne M.; Estrem, Hayley; Nix, W. Brant

    2016-01-01

    Purpose To test the milk flow rates and variability in flow rates of bottle nipples used after hospital discharge. Study Design and Methods Twenty-six nipple types that represented 15 common brands as well as variety in price per nipple and store location sold (e.g., Babies R’ Us, Walmart, Dollar Store) were chosen for testing. Ten of each nipple type (n=260 total) were tested by measuring the amount of infant formula expressed in one minute using a breast pump. Mean milk flow rate (mL/min) and coefficient of variation (CV) were calculated. Flow rates of nipples within brand were compared statistically. Results Milk flow rates varied from 1.68 mL/min for the Avent Natural Newborn Flow to 85.34 mL/min for the Dr. Brown’s Standard Y-cut. Variability between nipple types also varied widely, from .03 for the Dr. Brown’s Standard Level 3 to .37 for MAM Nipple 1 Slow Flow. Clinical Implications The extreme range of milk flow rates found may be significant for medically fragile infants being discharged home who are continuing to develop oral feeding skills. The name of the nipple does not provide clear information about the flow rate to guide parents in decision-making. Variability in flow rates within nipples of the same type may complicate oral feeding for the medically fragile infant who may not be able to adapt easily to change in flow rates. Both flow rate and variability should be considered when guiding parents to a nipple choice. PMID:27008466

  18. Effect of increasing dialysate flow rate on diffusive mass transfer of urea, phosphate and β2-microglobulin during clinical haemodialysis

    PubMed Central

    Bhimani, Jai P.; Ouseph, Rosemary; Ward, Richard A.

    2010-01-01

    Background. Diffusive clearance depends on blood and dialysate flow rates and the overall mass transfer area coefficient (KoA) of the dialyzer. Although KoA should be constant for a given dialyzer, urea KoA has been reported to vary with dialysate flow rate possibly because of improvements in flow distribution. This study examined the dependence of KoA for urea, phosphate and β2-microglobulin on dialysate flow rate in dialyzers containing undulating fibers to promote flow distribution and two different fiber packing densities. Methods. Twelve stable haemodialysis patients underwent dialysis with four different dialyzers, each used with a blood flow rate of 400 mL/min and dialysate flow rates of 350, 500 and 800 mL/min. Clearances of urea, phosphate and β2-microglobulin were measured and KoA values calculated. Results. Clearances of urea and phosphate, but not β2-microglobulin, increased significantly with increasing dialysate flow rate. However, increasing dialysate flow rate had no significant effect on KoA or Ko for any of the three solutes examined, although Ko for urea and phosphate increased significantly as the average flow velocity in the dialysate compartment increased. Conclusions. For dialyzers with features that promote good dialysate flow distribution, increasing dialysate flow rate beyond 600 mL/min at a blood flow rate of 400 mL/min is likely to have only a modest impact on dialyzer performance, limited to the theoretical increase predicted for a constant KoA. PMID:20543211

  19. Study of gas-liquid flow in model porous media for heterogeneous catalysis

    NASA Astrophysics Data System (ADS)

    Francois, Marie; Bodiguel, Hugues; Guillot, Pierre; Laboratory of the Future Team

    2015-11-01

    Heterogeneous catalysis of chemical reactions involving a gas and a liquid phase is usually achieved in fixed bed reactors. Four hydrodynamic regimes have been observed. They depend on the total flow rate and the ratio between liquid and gas flow rate. Flow properties in these regimes influence transfer rates. Rather few attempts to access local characterization have been proposed yet, though these seem to be necessary to better describe the physical mechanisms involved. In this work, we propose to mimic slices of reactor by using two-dimensional porous media. We have developed a two-dimensional system that is transparent to allow the direct observation of the flow and the phase distribution. While varying the total flow rate and the gas/liquid flow rate ratio, we observe two hydrodynamic regimes: at low flow rate, the gaseous phase is continuous (trickle flow), while it is discontinuous at higher flow rate (pulsed flow). Thanks to some image analysis techniques, we are able to quantify the local apparent liquid saturation in the system. Its fluctuations in time are characteristic of the transition between the two regimes: at low liquid flow rates, they are negligible since the liquid/gas interface is fixed, whereas at higher flow rates we observe an alternation between liquid and gas. This transition between trickle to pulsed flow is in relative good agreement with the existing state of art. However, we report in the pulsed regime important flow heterogeneities at the scale of a few pores. These heterogeneities are likely to have a strong influence on mass transfers. We acknowledge the support of Solvay.

  20. An investigation of the basic physics of irrigation in urology and the role of automated pump irrigation in cystoscopy.

    PubMed

    Chang, Dwayne; Manecksha, Rustom P; Syrrakos, Konstantinos; Lawrentschuk, Nathan

    2012-01-01

    To investigate the effects of height, external pressure, and bladder fullness on the flow rate in continuous, non-continuous cystoscopy and the automated irrigation fluid pumping system (AIFPS). Each experiment had two 2-litre 0.9% saline bags connected to a continuous, non-continuous cystoscope or AIFPS via irrigation tubing. Other equipment included height-adjustable drip poles, uroflowmetry devices, and model bladders. In Experiment 1, saline bags were elevated to measure the increment in flow rate. In Experiment 2, saline bags were placed under external pressures to evaluate the effect on flow rate. In Experiment 3, flow rate changes in response to variable bladder fullness were measured. Elevating saline bags caused an increase in flow rates, however the increment slowed down beyond a height of 80 cm. Increase in external pressure on saline bags elevated flow rates, but inconsistently. A fuller bladder led to a decrease in flow rates. In all experiments, the AIFPS posted consistent flow rates. Traditional irrigation systems were susceptible to changes in height of irrigation solution, external pressure application, and bladder fullness thus creating inconsistent flow rates. The AIFPS produced consistent flow rates and was not affected by any of the factors investigated in the study.

  1. Packet Scheduling Mechanism to Improve Quality of Short Flows and Low-Rate Flows

    NASA Astrophysics Data System (ADS)

    Yokota, Kenji; Asaka, Takuya; Takahashi, Tatsuro

    In recent years elephant flows are increasing by expansion of peer-to-peer (P2P) applications on the Internet. As a result, bandwidth is occupied by specific users triggering unfair resource allocation. The main packet-scheduling mechanism currently employed is first-in first-out (FIFO) where the available bandwidth of short flows is limited by elephant flows. Least attained service (LAS), which decides transfer priority of packets by the total amount of transferred data in all flows, was proposed to solve this problem. However, routers with LAS limit flows with large amount of transferred data even if they are low-rate. Therefore, it is necessary to improve the quality of low-rate flows with long holding times such as voice over Internet protocol (VoIP) applications. This paper proposes rate-based priority control (RBPC), which calculates the flow rate and control the priority by using it. Our proposed method can transfer short flows and low-rate flows in advance. Moreover, its fair performance is shown through simulations.

  2. Irrigant flow within a prepared root canal using various flow rates: a Computational Fluid Dynamics study.

    PubMed

    Boutsioukis, C; Lambrianidis, T; Kastrinakis, E

    2009-02-01

    To study using computer simulation the effect of irrigant flow rate on the flow pattern within a prepared root canal, during final irrigation with a syringe and needle. Geometrical characteristics of a side-vented endodontic needle and clinically realistic flow rate values were obtained from previous and preliminary studies. A Computational Fluid Dynamics (CFD) model was created using FLUENT 6.2 software. Calculations were carried out for five selected flow rates (0.02-0.79 mL sec(-1)) and velocity and turbulence quantities along the domain were evaluated. Irrigant replacement was limited to 1-1.5 mm apical to the needle tip for all flow rates tested. Low-Reynolds number turbulent flow was detected near the needle outlet. Irrigant flow rate affected significantly the flow pattern within the root canal. Irrigation needles should be placed to within 1 mm from working length to ensure fluid exchange. Turbulent flow of irrigant leads to more efficient irrigant replacement. CFD represents a powerful tool for the study of irrigation.

  3. Adsorption of Rh(III) complexes from chloride solutions obtained by leaching chlorinated spent automotive catalysts on ion-exchange resin Diaion WA21J.

    PubMed

    Shen, Shaobo; Pan, Tonglin; Liu, Xinqiang; Yuan, Lei; Wang, Jinchao; Zhang, Yongjian; Guo, Zhanchen

    2010-07-15

    It was found that Rh, Pd and Pt contained in the spent ceramic automotive catalysts could be effectively extracted by dry chlorination with chlorine. In order to concentrate Rh(III) ions contained in the chloride solutions obtained, thermodynamic and kinetics studies for adsorption of Rh(III) complexes from the chloride solutions on an anionic exchange resin Diaion WA21J were carried out. Rh, Pd, Pt, Al, Fe, Si, Zn and Pb from the chloride solution could be adsorbed on the resin. The distribution coefficients (K(d)) of Rh(III) decreased with the increase in initial Rh(III) concentration or in adsorption temperature. The isothermal adsorption of Rh(III) was found to fit Langmuir, Freundlich and Dubinin-Kaganer-Radushkevich models under the adsorption conditions. The maximum monolayer adsorption capacities Q(max) based on Langmuir adsorption isotherms were 6.39, 6.61 and 5.81 mg/g for temperatures 18, 28 and 40 degrees C, respectively. The apparent adsorption energy of Rh was about -7.6 kJ/mol and thus Rh(III) adsorption was a physical type. The experimental data obtained could be better simulated by pseudo-first-order kinetic model and the activation energy obtained was 6.54 J/mol. The adsorption rate of Rh(III) was controlled by intraparticle diffusion in most of time of adsorption process. 2010 Elsevier B.V. All rights reserved.

  4. Relationship between salivary immunoglobulin a, lactoferrin and lysozyme flow rates and lifestyle factors in Japanese children: a cross-sectional study.

    PubMed

    Ide, Momo; Saruta, Juri; To, Masahiro; Yamamoto, Yuko; Sugimoto, Masahiro; Fuchida, Shinya; Yokoyama, Mina; Kimoto, Shigenari; Tsukinoki, Keiichi

    2016-10-01

    The antimicrobial substances in saliva contribute to the maintenance of both oral health and overall health of the body. Therefore, the associations among immunoglobulin A (IgA), lactoferrin and lysozyme flow rates in the saliva of children, and their relationships with the physical attributes and lifestyle factors of children, were examined. Saliva was collected from 90 children who visited the Kanagawa Dental University Hospital Pediatric Dentistry, and questionnaires were completed by guardians. IgA, lactoferrin and lysozyme concentrations were measured in the saliva samples using enzyme-linked immunosorbent assays (ELISAs). The IgA flow rate in saliva increased as age, height and weight increased. A correlation was found between lactoferrin and lysozyme flow rates. When the antimicrobial substance flow rates in the saliva were divided into two groups of 22 children each based on the highest and lowest quartiles, children with either a low or high IgA flow rate also had a high or low lactoferrin flow rate, respectively. The same pattern was observed for lactoferrin and lysozyme flow rates. There is a high probability that the IgA flow rate in the saliva of children reflects and corresponds to the developmental status of immune function as the child ages and increases in height and weight. The flow rates of lactoferrin and lysozyme were correlated in children. In addition, regarding lifestyle factors, the duration of sleep and lactoferrin flow rate were also related.

  5. Gas flow meter and method for measuring gas flow rate

    DOEpatents

    Robertson, Eric P.

    2006-08-01

    A gas flow rate meter includes an upstream line and two chambers having substantially equal, fixed volumes. An adjustable valve may direct the gas flow through the upstream line to either of the two chambers. A pressure monitoring device may be configured to prompt valve adjustments, directing the gas flow to an alternate chamber each time a pre-set pressure in the upstream line is reached. A method of measuring the gas flow rate measures the time required for the pressure in the upstream line to reach the pre-set pressure. The volume of the chamber and upstream line are known and fixed, thus the time required for the increase in pressure may be used to determine the flow rate of the gas. Another method of measuring the gas flow rate uses two pressure measurements of a fixed volume, taken at different times, to determine the flow rate of the gas.

  6. Evaluation of the effect of reactant gases mass flow rates on power density in a polymer electrolyte membrane fuel cell

    NASA Astrophysics Data System (ADS)

    Kahveci, E. E.; Taymaz, I.

    2018-03-01

    In this study it was experimentally investigated the effect of mass flow rates of reactant gases which is one of the most important operational parameters of polymer electrolyte membrane (PEM) fuel cell on power density. The channel type is serpentine and single PEM fuel cell has an active area of 25 cm2. Design-Expert 8.0 (trial version) was used with four variables to investigate the effect of variables on the response using. Cell temperature, hydrogen mass flow rate, oxygen mass flow rate and humidification temperature were selected as independent variables. In addition, the power density was used as response to determine the combined effects of these variables. It was kept constant cell and humidification temperatures while changing mass flow rates of reactant gases. From the results an increase occurred in power density with increasing the hydrogen flow rates. But oxygen flow rate does not have a significant effect on power density within determined mass flow rates.

  7. Estimation of inlet flow rates for image-based aneurysm CFD models: where and how to begin?

    PubMed

    Valen-Sendstad, Kristian; Piccinelli, Marina; KrishnankuttyRema, Resmi; Steinman, David A

    2015-06-01

    Patient-specific flow rates are rarely available for image-based computational fluid dynamics models. Instead, flow rates are often assumed to scale according to the diameters of the arteries of interest. Our goal was to determine how choice of inlet location and scaling law affect such model-based estimation of inflow rates. We focused on 37 internal carotid artery (ICA) aneurysm cases from the Aneurisk cohort. An average ICA flow rate of 245 mL min(-1) was assumed from the literature, and then rescaled for each case according to its inlet diameter squared (assuming a fixed velocity) or cubed (assuming a fixed wall shear stress). Scaling was based on diameters measured at various consistent anatomical locations along the models. Choice of location introduced a modest 17% average uncertainty in model-based flow rate, but within individual cases estimated flow rates could vary by >100 mL min(-1). A square law was found to be more consistent with physiological flow rates than a cube law. Although impact of parent artery truncation on downstream flow patterns is well studied, our study highlights a more insidious and potentially equal impact of truncation site and scaling law on the uncertainty of assumed inlet flow rates and thus, potentially, downstream flow patterns.

  8. Studies on the prevalence of reduced salivary flow rate in relation to general health and dental caries, and effect of iron supplementation.

    PubMed

    Flink, Håkan

    2007-01-01

    Reduced salivary flow is a condition that affects oral health. Its prevalence is unknown in young and middle-aged adults and there is no known treatment that permanently increases the salivary flow rate. Reduced salivary flow is related to dental caries, the most common oral disease. Reduced salivary flow is often found in individuals with insufficient food intake and thereby insufficient nutrition to the salivary glands. One nutrition related factor that has been proposed to effect salivary flow rate is iron deficiency. The aims of the thesis were to investigate i) the prevalence of reduced salivary flow rate in different age groups of adults, ii) the relationship between reduced salivary flow rate, general health and dental caries, iii) the influence of time of measurement on reduced salivary flow rate, and iv) if reduced salivary flow rates could be increased by iron supplementation. In Study I saliva was collected from 1427 individuals aged 20-69 years. A questionnaire was answered regarding subjective oral dryness, general diseases, use of drugs, BMI (Body Mass Index) and use of tobacco. In Study II saliva was collected from 48 patients with active caries and 48 caries-inactive patients. A blood sample was analysed for serum ferritin. In Study III the unstimulated salivary flow rate was tested at 7:30 and 11:30 a.m. in 108 individuals, age 15-46 years. The participants were allocated to one of three groups (very low < 0.1 mL/min, low 0.1-0.2 mL/min and normal > 0.2 mL/min) based on the the unstimulated salivary flow rate at 7:30 a.m. Different aspects of the perception of oral dryness were rated using Visual Analogue Scales. In Study IV a double-blind, randomized controlled trial was carried out on 50 individuals with a low unstimulated whole salivary flow rate and low serum ferritin. Half the individuals received 60 mg of iron orally twice a day for 3 months, while the other half received placebo. In Study I it was found that the prevalence of very low (< 0.1 mL/min) and low (0.10-0.19 mL/min) unstimulated salivary flow rate were similar for different age groups up to 50 years, ranging between 10.9-17.8% and 17.3-22.7%, respectively. Multiple logistic regression revealed that above age 50, female gender, 'having fewer than 20 teeth', and taking xerogenic drugs significantly increased the risk of very low unstimulated salivary flow rate. In Study II 32 individuals (67%) in the caries active group had low unstimulated salivary flow rate compared with 13 individuals (27%) in the caries inactive group. There was no difference in serum ferritin levels between the two groups. Study III showed for all groups a statistically significant increase in unstimulated salivary flow rate at 11:30 a.m. compared with 7:30 a.m., all of similar magnitude (0.08-0.09 mL/min). In the group with very low salivary flow rate, 70% at 11:30 a.m. exceeded the 0.1 mL/min limit. There were significant difference in perception of oral dryness between the normal group and both the low and the very low groups. In Study IV no statistically significant difference was found between the groups after treatment for the unstimulated flow rate and in the subjective assessments of oral dryness. The prevalence of reduced salivary flow rates is consistent and prevalent in younger and middle-aged adults (< 50 years). Very low salivary flow rates are related to high Body Mass Index (BMI) and diagnosed diseases in younger adults, but to medication in older adults. Reduced salivary flow rate in young adult women is related to caries. The time of measurement of salivary flow rates influences diagnosis of hyposalivation. Iron supplementation does not enhance salivary flow.

  9. Design and numerical simulation on an auto-cumulative flowmeter in horizontal oil-water two-phase flow

    NASA Astrophysics Data System (ADS)

    Xie, Beibei; Kong, Lingfu; Kong, Deming; Kong, Weihang; Li, Lei; Liu, Xingbin; Chen, Jiliang

    2017-11-01

    In order to accurately measure the flow rate under the low yield horizontal well conditions, an auto-cumulative flowmeter (ACF) was proposed. Using the proposed flowmeter, the oil flow rate in horizontal oil-water two-phase segregated flow can be finely extracted. The computational fluid dynamics software Fluent was used to simulate the fluid of the ACF in oil-water two-phase flow. In order to calibrate the simulation measurement of the ACF, a novel oil flow rate measurement method was further proposed. The models of the ACF were simulated to obtain and calibrate the oil flow rate under different total flow rates and oil cuts. Using the finite-element method, the structure of the seven conductance probes in the ACF was simulated. The response values for the probes of the ACF under the conditions of oil-water segregated flow were obtained. The experiments for oil-water segregated flow under different heights of the oil accumulation in horizontal oil-water two-phase flow were carried out to calibrate the ACF. The validity of the oil flow rate measurement in horizontal oil-water two-phase flow was verified by simulation and experimental results.

  10. Design and numerical simulation on an auto-cumulative flowmeter in horizontal oil-water two-phase flow.

    PubMed

    Xie, Beibei; Kong, Lingfu; Kong, Deming; Kong, Weihang; Li, Lei; Liu, Xingbin; Chen, Jiliang

    2017-11-01

    In order to accurately measure the flow rate under the low yield horizontal well conditions, an auto-cumulative flowmeter (ACF) was proposed. Using the proposed flowmeter, the oil flow rate in horizontal oil-water two-phase segregated flow can be finely extracted. The computational fluid dynamics software Fluent was used to simulate the fluid of the ACF in oil-water two-phase flow. In order to calibrate the simulation measurement of the ACF, a novel oil flow rate measurement method was further proposed. The models of the ACF were simulated to obtain and calibrate the oil flow rate under different total flow rates and oil cuts. Using the finite-element method, the structure of the seven conductance probes in the ACF was simulated. The response values for the probes of the ACF under the conditions of oil-water segregated flow were obtained. The experiments for oil-water segregated flow under different heights of the oil accumulation in horizontal oil-water two-phase flow were carried out to calibrate the ACF. The validity of the oil flow rate measurement in horizontal oil-water two-phase flow was verified by simulation and experimental results.

  11. Picoelectrospray Ionization Mass Spectrometry Using Narrow-bore Chemically Etched Emitters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marginean, Ioan; Tang, Keqi; Smith, Richard D.

    2014-01-01

    Electrospray ionization mass spectrometry (ESI-MS) at flow rates below ~10 nL/min has been only sporadically explored due to difficulty in reproducibly fabricating emitters that can operate at lower flow rates. Here we demonstrate narrow orifice chemically etched emitters for stable electrospray at flow rates as low as 400 pL/min. Depending on the analyte concentration, we observe two types of MS signal response as a function of flow rate. At low concentrations, an optimum flow rate is observed slightly above 1 nL/min, while the signal decreases monotonically with decreasing flow rates at higher concentrations. In spite of lower MS signal, themore » ion utilization efficiency increases exponentially with decreasing flow rate in all cases. No unimolecular response was observed within this flow rate range during the analysis of an equimolar mixture of peptides, indicating that ionization efficiency is an analyte-dependent characteristic in given experimental conditions. While little to no gain in signal-to-noise was achieved at ultralow flow rates for concentration-limited analyses, experiments consuming the same amount of analyte suggest that mass-limited analyses will benefit strongly from the use of low flow rates and avoiding unnecessary sample dilution. By operating under optimal conditions, consumption of just 500 zmol of sample yielded signal-to-noise ratios ~10 for some peptides. These findings have important implications for the analysis of trace biological samples.« less

  12. Influence of Reduced Mass Flow Rate and Chamber Backpressure on Swirl Injector Fluid Mechanics

    NASA Technical Reports Server (NTRS)

    Kenny, R Jeremy; Hulka, James R.

    2008-01-01

    Industry interest in variable-thrust liquid rocket engines places a demand on engine injector technology to operate over a wide range of liquid mass flow rates and chamber backpressures. One injection technology of current interest for variable thrust applications is an injector design with swirled fluids. Current swirl injector design methodologies do not take into account how swirl injector design parameters respond to elevated chamber backpressures at less than design mass flow rates. The current work was created to improve state-of-the-art swirl injector design methods in this area. The specific objective was to study the effects of elevated chamber backpressure and off-design mass flow rates on swirl injector fluid mechanics. Using a backpressure chamber with optical access, water was flowed through a swirl injector at various combinations of chamber backpressure and mass flow rates. The film thickness profile down the swirl injector nozzle section was measured through a transparent nozzle section of the injector. High speed video showed measurable increases in the film thickness profile with application of chamber backpressure and mass flow rates less than design. At prescribed combinations of chamber backpressure and injected mass flow rate, a discrete change in the film thickness profile was observed. Measured injector discharge coefficient values showed different trends with increasing chamber backpressure at low mass flow rates as opposed to near-design mass flow rates. Downstream spray angles showed classic changes in morphology as the mass flow rate was decreased below the design value. Increasing chamber backpressure decreased the spray angle at any injection mass flow rate. Experimental measurements and discussion of these results are reported in this paper.

  13. The minimum or natural rate of flow and droplet size ejected by Taylor cone-jets: physical symmetries and scaling laws

    NASA Astrophysics Data System (ADS)

    Gañán-Calvo, A. M.; Rebollo-Muñoz, N.; Montanero, J. M.

    2013-03-01

    We aim to establish the scaling laws for both the minimum rate of flow attainable in the steady cone-jet mode of electrospray, and the size of the resulting droplets in that limit. Use is made of a small body of literature on Taylor cone-jets reporting precise measurements of the transported electric current and droplet size as a function of the liquid properties and flow rate. The projection of the data onto an appropriate non-dimensional parameter space maps a region bounded by the minimum rate of flow attainable in the steady state. To explain these experimental results, we propose a theoretical model based on the generalized concept of physical symmetry, stemming from the system time invariance (steadiness). A group of symmetries rising at the cone-to-jet geometrical transition determines the scaling for the minimum flow rate and related variables. If the flow rate is decreased below that minimum value, those symmetries break down, which leads to dripping. We find that the system exhibits two instability mechanisms depending on the nature of the forces arising against the flow: one dominated by viscosity and the other by the liquid polarity. In the former case, full charge relaxation is guaranteed down to the minimum flow rate, while in the latter the instability condition becomes equivalent to the symmetry breakdown by charge relaxation or separation. When cone-jets are formed without artificially imposing a flow rate, a microjet is issued quasi-steadily. The flow rate naturally ejected this way coincides with the minimum flow rate studied here. This natural flow rate determines the minimum droplet size that can be steadily produced by any electrohydrodynamic means for a given set of liquid properties.

  14. Effects of atmospheric pressure conditions on flow rate of an elastomeric infusion pump.

    PubMed

    Wang, Jong; Moeller, Anna; Ding, Yuanpang Samuel

    2012-04-01

    The effects of pressure conditions, both hyperbaric and hypobaric, on the flow rate of an elastomeric infusion pump were investigated. The altered pressure conditions were tested with the restrictor outlet at two different conditions: (1) at the same pressure condition as the Infusor elastomeric balloon and (2) with the outlet exposed to ambient conditions. Five different pressure conditions were tested. These included ambient pressure (98-101 kilopascals [kPa]) and test pressures controlled to be 10 or 20 kPa below or 75 or 150 kPa above the ambient pressure. A theoretical calculation based on the principles of fluid mechanics was also used to predict the pump's flow rate at various ambient conditions. The conditions in which the Infusor elastomeric pump and restrictor outlet were at the same pressure gave rise to average flow rates within the ±10% tolerance of the calculated target flow rate of 11 mL/hr. The flow rate of the Infusor pump decreased when the pressure conditions changed from hypobaric to ambient. The flow rate increased when the pressure conditions changed from hyperbaric to ambient. The flow rate of the Infusor elastomeric pump was not affected when the balloon reservoir and restrictor outlet were at the same pressure. The flow rate varied from 58.54% to 377.04% of the labeled flow rate when the pressure applied to the reservoir varied from 20 kPa below to 150 kPa above the pressure applied to the restrictor outlet, respectively. The maximum difference between observed flow rates and those calculated by applying fluid mechanics was 4.9%.

  15. Growth rate of a penny-shaped crack in hydraulic fracturing of rocks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abe, H.; Keer, L.M.; Mura, T.

    1976-01-01

    The deformation and growth of a crack, fractured hydraulically, is investigated when fluid is injected from an inlet into the crack at a constant flow rate. The total flow rate at the inlet is divided as follows: flow rate extracted from an outlet hole; fluid loss rate from the crack surface; and total fluid mass change in the crack. Two cases are considered: (1) inlet flow rate is initially greater than the sum of the outlet flow and fluid loss rates; and (2) the reverse holds true. Ranges are shown for which the crack attains stationary states for given inletmore » flow rate and outlet pressure. For these two cases reasonable outlet flow rates are obtained when the outlet pressure is less than or equal to the difference between the tectonic stress and the fluid head at the inlet. Results are expected to be of use in considerations of heat extraction from hot, dry rock.« less

  16. Nonintrusive Flow Rate Determination Through Space Shuttle Water Coolant Loop Floodlight Coldplate

    NASA Technical Reports Server (NTRS)

    Werlink, Rudolph; Johnson, Harry; Margasahayam, Ravi

    1997-01-01

    Using a Nonintrusive Flow Measurement System (NFMS), the flow rates through the Space Shuttle water coolant coldplate were determined. The objective of this in situ flow measurement was to prove or disprove a potential block inside the affected coldplate had contributed to a reduced flow rate and the subsequent ice formation on the Space Shuttle Discovery. Flow through the coldplate was originally calculated to be 35 to 38 pounds per hour. This application of ultrasonic technology advanced the envelope of flow measurements through use of 1/4-inch-diameter tubing, which resulted in extremely low flow velocities (5 to 30 pounds per hour). In situ measurements on the orbiters Discovery and Atlantis indicated both vehicles, on the average, experienced similar flow rates through the coldplate (around 25 pounds per hour), but lower rates than the designed flow. Based on the noninvasive checks, further invasive troubleshooting was eliminated. Permanent monitoring using the NFMS was recommended.

  17. Effect of Flow Rate Controller on Liquid Steel Flow in Continuous Casting Mold using Numerical Modeling

    NASA Astrophysics Data System (ADS)

    Gursoy, Kadir Ali; Yavuz, Mehmet Metin

    2014-11-01

    In continuous casting operation of steel, the flow through tundish to the mold can be controlled by different flow rate control systems including stopper rod and slide-gate. Ladle changes in continuous casting machines result in liquid steel level changes in tundishes. During this transient event of production, the flow rate controller opening is increased to reduce the pressure drop across the opening which helps to keep the mass flow rate at the desired level for the reduced liquid steel level in tundish. In the present study, computational fluid dynamic (CFD) models are developed to investigate the effect of flow rate controller on mold flow structure, and particularly to understand the effect of flow controller opening on meniscus flow. First, a detailed validation of the CFD models is conducted using available experimental data and the performances of different turbulence models are compared. Then, the constant throughput casting operations for different flow rate controller openings are simulated to quantify the opening effect on meniscus region. The results indicate that the meniscus velocities are significantly affected by the flow rate controller and its opening level. The steady state operations, specified as constant throughput casting, do not provide the same mold flow if the controller opening is altered. Thus, for quality and castability purposes, adjusting the flow controller opening to obtain the fixed mold flow structure is proposed. Supported by Middle East Technical University (METU) BAP (Scientific Research Projects) Coordination.

  18. Heated, humidified high-flow nasal cannula therapy: yet another way to deliver continuous positive airway pressure?

    PubMed

    Kubicka, Zuzanna J; Limauro, Joseph; Darnall, Robert A

    2008-01-01

    The goal was to estimate the level of delivered continuous positive airway pressure by measuring oral cavity pressure with the mouth closed in infants of various weights and ages treated with heated, humidified high-flow nasal cannula at flow rates of 1-5 L/minute. We hypothesized that clinically relevant levels of continuous positive airway pressure would not be achieved if a nasal leak is maintained. After performing bench measurements and demonstrating that oral cavity pressure closely approximated levels of traditionally applied nasal continuous positive airway pressure, we successfully measured oral cavity pressure during heated, humidified, high-flow nasal cannula treatment in 27 infants. Small (outer diameter: 0.2 cm) cannulae were used for all infants, and flow rates were left as ordered by providers. Bench measurements showed that, for any given leak size, there was a nearly linear relationship between flow rate and pressure. The highest pressure achieved was 4.5 cmH2O (flow rate: 8 L/minute; leak: 3 mm). In our study infants (postmenstrual age: 29.1-44.7 weeks; weight: 835-3735 g; flow rate: 1-5 L/minute), no pressure was generated with the mouth open at any flow rate. With the mouth closed, the oral cavity pressure was related to both flow rate and weight. For infants of < or = 1500 g, there was a linear relationship between flow rate and oral cavity pressure. Oral cavity pressure can estimate the level of continuous positive airway pressure. Continuous positive airway pressure generated with heated, humidified, high-flow nasal cannula treatment depends on the flow rate and weight. Only in the smallest infants with the highest flow rates, with the mouth fully closed, can clinically significant but unpredictable levels of continuous positive airway pressure be achieved. We conclude that heated, humidified high-flow nasal cannula should not be used as a replacement for delivering continuous positive airway pressure.

  19. [Biosorption ability of mutants of Rhodotorula mucilaginosa UCM Y-1776].

    PubMed

    Mamieieva, O H; Kasatkina, T P; Lavrinchuk, V Ia

    2007-01-01

    Twenty stable mutants with various coloration intensity have been allocated in carotene-synthesizing natural strain Rhodotorula mucilaginosa UCM Y-1776 (wild type) after nitrosoguanidine action. Two brightly orange mutants 4L and 11 and one non-pigmented mutant 2 were chosen for the further researches. The ultraviolet was inefficient as a mutagen. Resistance to high concentration of copper ions (up to 200 mg/g), high sorption ability (Qmax = 9.1 mmol/g) was characteristic of R. mucilaginosa UCM Y-1776. Concentration of copper ions 50 mg/l was toxic for mutants 4L, 11 and 2, which sorption ability was lower in comparison with carotene pigmented R. mucilaginosa UCM Y-1776. It was shown, for the first time that there was a direct dependence between the presence of carotenoid pigments, resistance to high concentration of copper ions and sorption ability for yeast R. mucilaginosa UCM Y-1776.

  20. Nonintrusive performance measurement of a gas turbine engine in real time

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DeSilva, Upul P.; Claussen, Heiko

    Performance of a gas turbine engine is monitored by computing a mass flow rate through the engine. Acoustic time-of-flight measurements are taken between acoustic transmitters and receivers in the flow path of the engine. The measurements are processed to determine average speeds of sound and gas flow velocities along those lines-of-sound. A volumetric flow rate in the flow path is computed using the gas flow velocities together with a representation of the flow path geometry. A gas density in the flow path is computed using the speeds of sound and a measured static pressure. The mass flow rate is calculatedmore » from the gas density and the volumetric flow rate.« less

  1. Performance Mapping Studies in Redox Flow Cells

    NASA Technical Reports Server (NTRS)

    Hoberecht, M. A.; Thaller, L. H.

    1981-01-01

    Pumping power requirements in any flow battery system constitute a direct parasitic energy loss. It is therefore useful to determine the practical lower limit for reactant flow rates. Through the use of a theoretical framework based on electrochemical first principles, two different experimental flow mapping techniques were developed to evaluate and compare electrodes as a function of flow rate. For the carbon felt electrodes presently used in NASA-Lewis Redox cells, a flow rate 1.5 times greater than the stoichiometric rate seems to be the required minimum.

  2. Measurement and numerical simulation of a small centrifugal compressor characteristics at small or negative flow rate

    NASA Astrophysics Data System (ADS)

    Tsukamoto, Kaname; Okada, Mizuki; Inokuchi, Yuzo; Yamasaki, Nobuhiko; Yamagata, Akihiro

    2017-04-01

    For centrifugal compressors used in automotive turbochargers, the extension of the surge margin is demanded because of lower engine speed. In order to estimate the surge line exactly, it is required to acquire the compressor characteristics at small or negative flow rate. In this paper, measurement and numerical simulation of the characteristics at small or negative flow rate are carried out. In the measurement, an experimental facility with a valve immediately downstream of the compressor is used to suppress the surge. In the numerical work, a new boundary condition that specifies mass flow rate at the outlet boundary is used to simulate the characteristics around the zero flow rate region. Furthermore, flow field analyses at small or negative flow rate are performed with the numerical results. The separated and re-circulated flow fields are investigated by visualization to identify the origin of losses.

  3. Cool-down flow-rate limits imposed by thermal stresses in LNG pipelines

    NASA Astrophysics Data System (ADS)

    Novak, J. K.; Edeskuty, F. J.; Bartlit, J. R.

    Warm cryogenic pipelines are usually cooled to operating temperature by a small, steady flow of the liquid cryogen. If this flow rate is too high or too low, undesirable stresses will be produced. Low flow-rate limits based on avoidance of stratified two-phase flow were calculated for pipelines cooled with liquid hydrogen or nitrogen. High flow-rate limits for stainless steel and aluminum pipelines cooled by liquid hydrogen or nitrogen were determined by calculating thermal stress in thick components vs flow rate and then selecting some reasonable stress limits. The present work extends these calculations to pipelines made of AISI 304 stainless steel, 6061 aluminum, or ASTM A420 9% nickel steel cooled by liquid methane or a typical natural gas. Results indicate that aluminum and 9% nickel steel components can tolerate very high cool-down flow rates, based on not exceeding the material yield strength.

  4. Eruption rate, area, and length relationships for some Hawaiian lava flows

    NASA Technical Reports Server (NTRS)

    Pieri, David C.; Baloga, Stephen M.

    1986-01-01

    The relationships between the morphological parameters of lava flows and the process parameters of lava composition, eruption rate, and eruption temperature were investigated using literature data on Hawaiian lava flows. Two simple models for lava flow heat loss by Stefan-Boltzmann radiation were employed to derive eruption rate versus planimetric area relationship. For the Hawaiian basaltic flows, the eruption rate is highly correlated with the planimetric area. Moreover, this observed correlation is superior to those from other obvious combinations of eruption rate and flow dimensions. The correlations obtained on the basis of the two theoretical models, suggest that the surface of the Hawaiian flows radiates at an effective temperature much less than the inner parts of the flowing lava, which is in agreement with field observations. The data also indicate that the eruption rate versus planimetric area correlations can be markedly degraded when data from different vents, volcanoes, and epochs are combined.

  5. Performance of a restrictive flow device and an electronic syringe driver for continuous subcutaneous infusion.

    PubMed

    Capes, D; Martin, K; Underwood, R

    1997-10-01

    The aim of this study was to investigate the flow performance of the mechanical Springfusor 30 short model and the electronic Graseby MS16A. Flow rate was measured gravimetrically in a temperature-controlled cabinet. There was no statistically significant difference between the Graseby and Springfusor syringe drivers in the flow rate error at 25 degrees C. The percentage of flow rates within +/-20% accuracy during a 35-min periods at 25 degrees C was significantly less with the Graseby, being 91.9% compared with 100% for the Springfusor. Only 58.2% of flow rates with the Graseby were within the manufacturer claimed accuracy of +/-5%. The flow rate of the Springfusor was affected by temperature; at 30 degrees C the mean flow rate was 10.8% greater than at 25 degrees C. These results indicate that the Springfusor 30 had less flow rate variation than the Graseby MS16A. However, this would not be expected to cause noticeable clinical effects when used for opioid infusion in palliative care.

  6. The effects of recirculation flows on mass transfer from the arterial wall to flowing blood.

    PubMed

    Zhang, Zhiguo; Deng, Xiaoyan; Fan, Yubo; Guidoin, Robert

    2008-01-01

    Using a sudden tubular expansion as a model of an arterial stenosis, the effect of disturbed flow on mass transfer from the arterial wall to flowing blood was studied theoretically and tested experimentally by measuring the dissolution rate of benzoic acid disks forming the outer tube of a sudden tubular expansion. The study revealed that mass transfer from vessel wall to flowing fluid in regions of disturbed flow is independent of wall shear rates. The rate of mass transfer is significantly higher in regions of disturbed flow with a local maximum around the reattachment point where the wall shear rate is zero. The experimental study also revealed that the rate of mass transfer from the vessel wall to a flowing fluid is much higher in the presence of microspheres (as models of blood cells) in the flowing fluid and under the condition of pulsatile flow than in steady flow. These results imply that flow disturbance may enhance the transport of biochemicals and macromolecules, such as plasma proteins and lipoproteins synthesized within the blood vessel wall, from the blood vessel wall to flowing blood.

  7. Assessing hydrodynamic effects on jarosite dissolution rates, reaction products, and preservation on Mars

    NASA Astrophysics Data System (ADS)

    Dixon, Emily M.; Elwood Madden, Andrew S.; Hausrath, Elisabeth M.; Elwood Madden, Megan E.

    2015-04-01

    Jarosite flow-through dissolution experiments were conducted in ultrapure water (UPW), pH 2 sulfuric acid, and saturated NaCl and CaCl2 brines at 295-298 K to investigate how hydrologic variables may affect jarosite preservation and reaction products on Mars. K+-based dissolution rates in flowing UPW did not vary significantly with flow rate, indicating that mineral surface reactions control dissolution rates over the range of flow rates investigated. In all of the solutions tested, hydrologic variables do not significantly affect extent of jarosite alteration; therefore, jarosite is equally likely to be preserved in flowing or stagnant waters on Mars. However, increasing flow rate did affect the mineralogy and accumulation of secondary reaction products. Iron release rates in dilute solutions increased as the flow rate increased, likely due to nanoscale iron (hydr)oxide transport in flowing water. Anhydrite formed in CaCl2 brine flow-through experiments despite low temperatures, while metastable gypsum and bassanite were observed in batch experiments. Therefore, observations of the hydration state of calcium sulfate minerals on Mars may provide clues to unravel past salinity and hydrologic conditions as well as temperatures and vapor pressures.

  8. Measuring Flow Rate in Crystalline Bedrock Wells Using the Dissolved Oxygen Alteration Method.

    PubMed

    Vitale, Sarah A; Robbins, Gary A

    2017-07-01

    Determination of vertical flow rates in a fractured bedrock well can aid in planning and implementing hydraulic tests, water quality sampling, and improving interpretations of water quality data. Although flowmeters are highly accurate in flow rate measurement, the high cost and logistics may be limiting. In this study the dissolved oxygen alteration method (DOAM) is expanded upon as a low-cost alternative to determine vertical flow rates in crystalline bedrock wells. The method entails altering the dissolved oxygen content in the wellbore through bubbler aeration, and monitoring the vertical advective movement of the dissolved oxygen over time. Measurements were taken for upward and downward flows, and under ambient and pumping conditions. Vertical flow rates from 0.06 to 2.30 Lpm were measured. To validate the method, flow rates determined with the DOAM were compared to pump discharge rates and found to be in agreement within 2.5%. © 2017, National Ground Water Association.

  9. Topological transitions in unidirectional flow of nematic liquid crystal

    NASA Astrophysics Data System (ADS)

    Cummings, Linda; Anderson, Thomas; Mema, Ensela; Kondic, Lou

    2015-11-01

    Recent experiments by Sengupta et al. (Phys. Rev. Lett. 2013) revealed interesting transitions that can occur in flow of nematic liquid crystal under carefully controlled conditions within a long microfluidic channel of rectangular cross-section, with homeotropic anchoring at the walls. At low flow rates the director field of the nematic adopts a configuration that is dominated by the surface anchoring, being nearly parallel to the channel height direction over most of the cross-section; but at high flow rates there is a transition to a flow-dominated state, where the director configuration at the channel centerline is aligned with the flow (perpendicular to the channel height direction). We analyze simple channel-flow solutions to the Leslie-Ericksen model for nematics. We demonstrate that two solutions exist, at all flow rates, but that there is a transition between the elastic free energies of these solutions: the anchoring-dominated solution has the lowest energy at low flow rates, and the flow-dominated solution has lowest energy at high flow rates. NSF DMS 1211713.

  10. [Recommendations for the urodynamic examination in the investigation of non-neurological female urinary incontinence].

    PubMed

    Hermieu, Jean François

    2007-11-01

    INDICATIONS FOR URODYNAMIC ASSESSMENT IN WOMEN: Urodynamic assessment is not useful for the diagnosis of female urinary incontinence which remains a clinical diagnosis. Before any form of surgery for pure stress urinary incontinence, evaluation of bladder emptying by determination of maximum flow rate and residual urine is recommended. In the presence of pure stress urinary incontinence with no other associated clinical symptoms, a complete urodynamic assessment is not mandatory, but can be helpful to define the prognosis and inform the patient about her vesicosphincteric function. On the other hand, a complete urodynamic assessment is recommended to investigate complex or complicated urinary incontinence, mainly in the case of: history of surgery for urinary incontinence. urgency with or without urine leakage, severe urinary incontinence, voiding abnormalities, negative cough test, decreased bladder capacity, suspected obstruction or decreased bladder contractility, failure of first-line treatment. PATIENT PREPARATION: The patient should be thoroughly informed about the examination procedure and its possible consequences. The patient should be advised to attend the examination with a normal desire to urinate. Urodynamic assessment must not be performed in the presence of untreated urinary tract infection. Antibiotic prophylaxis is not recommended. UROFLOWMETRY: The flowmeter must be regularly calibrated and must be installed in a quiet room. Whenever possible, uroflowmetry should be performed before cystometry with a normal desire to urinate. The patient should be advised to urinate normally without straining and by staying as relaxed as possible. During voiding, all of the stream must enter the flowmeter. The main parameters recorded are Qmax (expressed in ml/s), the voided volume (expressed in ml), and the appearance of the curve. The examination must be interpreted manually without taking into account the automated interpretation. GUIDELINES CONCERNING CYSTOMETRY EQUIPMENT: A three pressure line configuration is recommended. Bladder filling must be performed with a sterile liquid; filling with gas is no longer recommended. Bladder filling is ideally performed by a pump ensuring a sufficiently slow flow rate to avoid modifying bladder behaviour (< 50 ml/min). It is essential to determine and check the volume infused into the bladder. When a peristaltic pump is used, the bladder filling catheter must be adapted to the pump. Water or electronic transducers can be used to measure bladder pressure. Balloon catheters filled with air appear to be sufficiently precise to perform pressure measurements in a manometric chamber (during cystometry) but not in a virtual cavity such as the urethra (during the urethral pressure profile). Measurement of abdominal pressure is recommended, either via the infusion catheter or preferably by a rectal balloon catheter. GUIDELINES ON THE PRACTICAL CONDITIONS OF CYSTOMETRY: The equipment must be regularly calibrated. Make sure that the bladder is empty before starting cystometry. Transducers are zeroed at the superior extremity of the pubic symphysis for infused transducers and at atmospheric pressure for electronic and air transducers. Tubings must be correctly connected without kinks, bubbles or leaks. The catheter must be selected according to its technical characteristics, particularly its pressure loss. After filling for one or two minutes, the patient is asked to cough to ensure a similar increase in both abdominal pressure and bladder pressure. The following parameters are recorded: baseline detrusor pressure, first desire to void, detrusor activity, bladder capacity and bladder compliance. Measurement of bladder pressure during voiding is used to confirm whether or not the bladder is contractile, assess obstruction in the case of low urine flow rate with high bladder pressure, and detect abdominal straining. Good test conditions must be ensured in order to obtain good quality voiding. In the case of incoherent results, the bladder should be re-filled after checking the equipment. MEASUREMENT AND INTERPRETATION OF URETHRAL PRESSURE: To obtain a reliable measurement of urethral pressure, it is recommended to: Define the normal values used. Use a catheter smaller than 12 F. Perform a circumferential measurement. Use a catheter with an infusion rate of 2 ml/min. Remove the catheter at a rate of 1 mm/s. Perform the examination in the seating or supine position with a half-full bladder after reducing any prolapse. Repeat the measurements. THE FOLLOWING ELEMENTS MUST BE TAKEN INTO ACCOUNT WHEN INTERPRETING AN URETHRAL PRESSURE PROFILE: The functional urethral length is neither a diagnostic criterion nor a prognostic criterion of urinary incontinence. The urethral pressure profile cannot be considered to be a useful test for the diagnosis of female urinary incontinence. However, in combination with clinical criteria, it is predictive of the results of female stress urinary incontinence surgical repair techniques. The pressure transmission ratio is neither a diagnostic criterion nor a prognostic criterion of urinary incontinence.

  11. Noninvasive blood-flow meter using a curved cannula with zero compensation for an axial flow blood pump.

    PubMed

    Kosaka, Ryo; Fukuda, Kyohei; Nishida, Masahiro; Maruyama, Osamu; Yamane, Takashi

    2013-01-01

    In order to monitor the condition of a patient using a left ventricular assist system (LVAS), blood flow should be measured. However, the reliable determination of blood-flow rate has not been established. The purpose of the present study is to develop a noninvasive blood-flow meter using a curved cannula with zero compensation for an axial flow blood pump. The flow meter uses the centrifugal force generated by the flow rate in the curved cannula. Two strain gauges served as sensors. The first gauges were attached to the curved area to measure static pressure and centrifugal force, and the second gauges were attached to straight area to measure static pressure. The flow rate was determined by the differences in output from the two gauges. The zero compensation was constructed based on the consideration that the flow rate could be estimated during the initial driving condition and the ventricular suction condition without using the flow meter. A mock circulation loop was constructed in order to evaluate the measurement performance of the developed flow meter with zero compensation. As a result, the zero compensation worked effectively for the initial calibration and the zero-drift of the measured flow rate. We confirmed that the developed flow meter using a curved cannula with zero compensation was able to accurately measure the flow rate continuously and noninvasively.

  12. Flow Rate Through Pigtail Catheter Used for Left Heart Decompression in an Artificial Model of Extracorporeal Membrane Oxygenation Circuit.

    PubMed

    Kim, Won Ho; Hong, Tae Hee; Byun, Joung Hun; Kim, Jong Woo; Kim, Sung Hwan; Moon, Sung Ho; Park, Hyun Oh; Choi, Jun Young; Yang, Jun Ho; Jang, In Seok; Lee, Chung Eun; Yun, Jeong Hee

    In refractory cardiogenic shock, veno-arterial extracorporeal membrane oxygenation (ECMO) can be initiated. Although left heart decompression can be accomplished by insertion of a left atrial (LA) or left ventricular (LV) cannula using a percutaneous pigtail catheter, the venting flow rate according to catheter size and ECMO flow rate is unknown. We developed an artificial ECMO circuit. One liter saline bag with its pressure set to 20 mm Hg was connected to ECMO to mimic LV failure. A pigtail catheter was inserted into the 1 L saline bag to simulate LV unloading. For each pigtail catheter size (5-8 Fr) and ECMO flow rate (2.0-4.0 L/min), the moving distance of an air bubble that was injected through a three-way stopcock was measured in the arterial pressure line between the pigtail catheter and ECMO inflow limb. The flow rate was then calculated. We obtained the following equation to estimate the pigtail catheter flow rate.Pigtail vent catheter flow rate (ml/min) = 8×ECMOflow rate(L /min)+9×pigtail catheter size(Fr)- 57This equation would aid in designing of a further study to determine optimal venting flow rate. To achieve optimal venting flow, our equation would enable selection of an adequate catheter size.

  13. The Effects of Tooth Brushing on Whole Salivary Flow Rate in Older Adults

    PubMed Central

    Trottier, K.; Garrick, R.; Mascarenhas, T.; Jang, Y.

    2018-01-01

    Objectives (1) To determine whether manual (MTB), or electric, tooth brushing (ETB) modulates whole salivary flow rate in older adults who are free of systemic disease. (2) To determine the duration of the brushing-related modulation of salivary flow rate. (3) To compare salivary flow rate modulation associated with MTB and ETB. Method Twenty-one adults aged 60 years and older participated in two experimental sessions during which they used a manual, or electric, toothbrush to brush their teeth, tongue, and palate. Whole salivary flow rates were determined using the draining method before, during, and after brushing. Differences in salivary flow rates across time periods, and between conditions, were examined using paired samples t-tests applying a Holm-Bonferroni sequential procedure (pcorr < 0.0045). The relationship between tooth brushing and age with respect to maximum salivary flow rate increase was examined using Pearson's correlation coefficient (p < 0.05). Results/Conclusion Whole salivary flow rates increased during, and for up to 5 minutes following, tooth brushing in adults aged 60 years and older who were free of systemic disease. The salivary effects of MTB and ETB were not significantly different. A moderate, positive correlation was observed between tooth-brushing-related maximum salivary flow rate increase and age. PMID:29682540

  14. Identifying High-Rate Flows Based on Sequential Sampling

    NASA Astrophysics Data System (ADS)

    Zhang, Yu; Fang, Binxing; Luo, Hao

    We consider the problem of fast identification of high-rate flows in backbone links with possibly millions of flows. Accurate identification of high-rate flows is important for active queue management, traffic measurement and network security such as detection of distributed denial of service attacks. It is difficult to directly identify high-rate flows in backbone links because tracking the possible millions of flows needs correspondingly large high speed memories. To reduce the measurement overhead, the deterministic 1-out-of-k sampling technique is adopted which is also implemented in Cisco routers (NetFlow). Ideally, a high-rate flow identification method should have short identification time, low memory cost and processing cost. Most importantly, it should be able to specify the identification accuracy. We develop two such methods. The first method is based on fixed sample size test (FSST) which is able to identify high-rate flows with user-specified identification accuracy. However, since FSST has to record every sampled flow during the measurement period, it is not memory efficient. Therefore the second novel method based on truncated sequential probability ratio test (TSPRT) is proposed. Through sequential sampling, TSPRT is able to remove the low-rate flows and identify the high-rate flows at the early stage which can reduce the memory cost and identification time respectively. According to the way to determine the parameters in TSPRT, two versions of TSPRT are proposed: TSPRT-M which is suitable when low memory cost is preferred and TSPRT-T which is suitable when short identification time is preferred. The experimental results show that TSPRT requires less memory and identification time in identifying high-rate flows while satisfying the accuracy requirement as compared to previously proposed methods.

  15. Decline of the performance of a portable axial-flow fan due to the friction and duct bending loss of a connected flexible duct.

    PubMed

    Ojima, Jun

    2017-03-28

    In a job site, a portable fan is often used to ventilate a confined space. When a portable fan is applied to such a space, the actual ventilation flow rate must be accurately estimated in advance because the safety level of contaminant and oxygen concentrations in the space will determine the ventilation requirements. When a portable fan is used with a flexible duct, the actual flow rate of the fan decreases due to the friction and duct bending loss of the duct. Intending to show the decline of a fan performance, the author conducted laboratory experiments and reported the quantitative effect of the friction and duct bending loss of a flexible duct to the flow rate of a portable fan. Four commercial portable fans of different specifications were procured for the experiments, and the decline of the performance of each portable fan due to the friction loss etc. of a connected flexible duct was investigated by measuring actual flow rate. The flow rate showed an obvious decrease from the rated flow rate when a flexible duct was connected. Connection of a straight polyester flexible duct and a straight aluminum flexible duct reduced the flow rates to 81.2 - 52.9% and less than 50%, respectively. The flow rate decreased with an increase of the bend angle of the flexible duct. It is recommended that flow rate check of a portable fan should be diligently carried out in every job site.

  16. Evaluation of IOM personal sampler at different flow rates.

    PubMed

    Zhou, Yue; Cheng, Yung-Sung

    2010-02-01

    The Institute of Occupational Medicine (IOM) personal sampler is usually operated at a flow rate of 2.0 L/min, the rate at which it was designed and calibrated, for sampling the inhalable mass fraction of airborne particles in occupational environments. In an environment of low aerosol concentrations only small amounts of material are collected, and that may not be sufficient for analysis. Recently, a new sampling pump with a flow rate up to 15 L/min became available for personal samplers, with the potential of operating at higher flow rates. The flow rate of a Leland Legacy sampling pump, which operates at high flow rates, was evaluated and calibrated, and its maximum flow was found to be 10.6 L/min. IOM samplers were placed on a mannequin, and sampling was conducted in a large aerosol wind tunnel at wind speeds of 0.56 and 2.22 m/s. Monodisperse aerosols of oleic acid tagged with sodium fluorescein in the size range of 2 to 100 microm were used in the test. The IOM samplers were operated at flow rates of 2.0 and 10.6 L/min. Results showed that the IOM samplers mounted in the front of the mannequin had a higher sampling efficiency than those mounted at the side and back, regardless of the wind speed and flow rate. For the wind speed of 0.56 m/s, the direction-averaged (the average value of all orientations facing the wind direction) sampling efficiency of the samplers operated at 2.0 L/min was slightly higher than that of 10.6 L/min. For the wind speed of 2.22 m/s, the sampling efficiencies at both flow rates were similar for particles < 60 microm. The results also show that the IOM's sampling efficiency at these two different flow rates follows the inhalable mass curve for particles in the size range of 2 to 20 microm. The test results indicate that the IOM sampler can be used at higher flow rates.

  17. Unraveling the relationship between arterial flow and intra-aneurysmal hemodynamics.

    PubMed

    Morales, Hernán G; Bonnefous, Odile

    2015-02-26

    Arterial flow rate affects intra-aneurysmal hemodynamics but it is not clear how their relationship is. This uncertainty hinders the comparison among studies, including clinical evaluations, like a pre- and post-treatment status, since arterial flow rates may differ at each time acquisition. The purposes of this work are as follows: (1) To study how intra-aneurysmal hemodynamics changes within the full physiological range of arterial flow rates. (2) To provide characteristic curves of intra-aneurysmal velocity, wall shear stress (WSS) and pressure as functions of the arterial flow rate. Fifteen image-based aneurysm models were studied using computational fluid dynamics (CFD) simulations. The full range of physiological arterial flow rates reported in the literature was covered by 11 pulsatile simulations. For each aneurysm, the spatiotemporal-averaged blood flow velocity, WSS and pressure were calculated. Spatiotemporal-averaged velocity inside the aneurysm linearly increases as a function of the mean arterial flow (minimum R(2)>0.963). Spatiotemporal-averaged WSS and pressure at the aneurysm wall can be represented by quadratic functions of the arterial flow rate (minimum R(2)>0.996). Quantitative characterizations of spatiotemporal-averaged velocity, WSS and pressure inside cerebral aneurysms can be obtained with respect to the arterial flow rate. These characteristic curves provide more information of the relationship between arterial flow and aneurysm hemodynamics since the full range of arterial flow rates is considered. Having these curves, it is possible to compare experimental studies and clinical evaluations when different flow conditions are used. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Flow Cell Design for Effective Biosensing

    PubMed Central

    Pike, Douglas J.; Kapur, Nikil; Millner, Paul A.; Stewart, Douglas I.

    2013-01-01

    The efficiency of three different biosensor flow cells is reported. All three flow cells featured a central channel that expands in the vicinity of the sensing element to provide the same diameter active region, but the rate of channel expansion and contraction varied between the designs. For each cell the rate at which the analyte concentration in the sensor chamber responds to a change in the influent analyte concentration was determined numerically using a finite element model and experimentally using a flow-fluorescence technique. Reduced flow cell efficiency with increasing flow rates was observed for all three designs and was related to the increased importance of diffusion relative to advection, with efficiency being limited by the development of regions of recirculating flow (eddies). However, the onset of eddy development occurred at higher flow rates for the design with the most gradual channel expansion, producing a considerably more efficient flow cell across the range of flow rates considered in this study. It is recommended that biosensor flow cells be designed to minimize the tendency towards, and be operated under conditions that prevent the development of flow recirculation. PMID:23344373

  19. Handpiece coolant flow rates and dental cutting.

    PubMed

    von Fraunhofer, J A; Siegel, S C; Feldman, S

    2000-01-01

    High-speed handpieces incorporate water coolant sprays to remove cutting debris and minimize thermal insult to the pulp. Little data exists on optimal coolant flow rates during clinical procedures. This study compared the effect of different coolant flow rates on diamond stone cutting efficiency. Cutting studies were performed on Macor machinable ceramic using a previously developed test regimen--a KaVo high-speed handpiece at a cutting force of 91.5 g (0.9 N). Cutting was performed with round end tapered medium grit diamond stones under cooling water flow rates of 15, 20, 25, 30 and 44 ml/min, with cutting rates determined as the time to transect the 13 mm square cross-section of the Macor bar. Each bur was used for five cuts, with six burs used for each flow rate, for a total of 150 measurements. The data were analyzed by one-way ANOVA with a post hoc Scheffé test. The cutting studies indicated that diamond stone cutting rates increased with higher coolant flow rates over the range of 15-44 ml/min. The data suggest that higher coolant flow rates promote cutting efficiency.

  20. An empirical method for estimating travel times for wet volcanic mass flows

    USGS Publications Warehouse

    Pierson, Thomas C.

    1998-01-01

    Travel times for wet volcanic mass flows (debris avalanches and lahars) can be forecast as a function of distance from source when the approximate flow rate (peak discharge near the source) can be estimated beforehand. The near-source flow rate is primarily a function of initial flow volume, which should be possible to estimate to an order of magnitude on the basis of geologic, geomorphic, and hydrologic factors at a particular volcano. Least-squares best fits to plots of flow-front travel time as a function of distance from source provide predictive second-degree polynomial equations with high coefficients of determination for four broad size classes of flow based on near-source flow rate: extremely large flows (>1 000 000 m3/s), very large flows (10 000–1 000 000 m3/s), large flows (1000–10 000 m3/s), and moderate flows (100–1000 m3/s). A strong nonlinear correlation that exists between initial total flow volume and flow rate for "instantaneously" generated debris flows can be used to estimate near-source flow rates in advance. Differences in geomorphic controlling factors among different flows in the data sets have relatively little effect on the strong nonlinear correlations between travel time and distance from source. Differences in flow type may be important, especially for extremely large flows, but this could not be evaluated here. At a given distance away from a volcano, travel times can vary by approximately an order of magnitude depending on flow rate. The method can provide emergency-management officials a means for estimating time windows for evacuation of communities located in hazard zones downstream from potentially hazardous volcanoes.

  1. Glottal volume velocity waveform characteristics in subjects with and without vocal training, related to gender, sound intensity, fundamental frequency, and age.

    PubMed

    Sulter, A M; Wit, H P

    1996-11-01

    Glottal volume velocity waveform characteristics of 224 subjects, categorized in four groups according to gender and vocal training, were determined, and their relations to sound-pressure level, fundamental frequency, intra-oral pressure, and age were analyzed. Subjects phonated at three intensity conditions. The glottal volume velocity waveforms were obtained by inverse filtering the oral flow. Glottal volume velocity waveforms were parameterized with flow-based (minimum flow, ac flow, average flow, maximum flow declination rate) and time-based parameters (closed quotient, closing quotient, speed quotient), as well as with derived parameters (vocal efficiency and glottal resistance). Higher sound-pressure levels, intra-oral pressures, and flow-parameter values (ac flow, maximum flow declination rate) were observed, when compared with previous investigations. These higher values might be the result of the specific phonation tasks (stressed /ae/ vowel in a word and a sentence) or filtering processes. Few statistically significant (p < 0.01) differences in parameters were found between untrained and trained subjects [the maximum flow declination rate and the closing quotient were higher in trained women (p < 0.001), and the speed quotient was higher in trained men (p < 0.005)]. Several statistically significant parameter differences were found between men and women [minimum flow, ac flow, average flow, maximum flow declination rate, closing quotient, glottal resistance (p < 0.001), and closed quotient (p < 0.005)]. Significant effects of intensity condition were observed on ac flow, maximum flow declination rate, closing quotient, and vocal efficiency in women (p < 0.005), and on minimum flow, ac flow, average flow, maximum flow declination rate, closed quotient, and vocal efficiency in men (p < 0.01).

  2. Experimental measurement of oil-water two-phase flow by data fusion of electrical tomography sensors and venturi tube

    NASA Astrophysics Data System (ADS)

    Liu, Yinyan; Deng, Yuchi; Zhang, Maomao; Yu, Peining; Li, Yi

    2017-09-01

    Oil-water two-phase flows are commonly found in the production processes of the petroleum industry. Accurate online measurement of flow rates is crucial to ensure the safety and efficiency of oil exploration and production. A research team from Tsinghua University has developed an experimental apparatus for multiphase flow measurement based on an electrical capacitance tomography (ECT) sensor, an electrical resistance tomography (ERT) sensor, and a venturi tube. This work presents the phase fraction and flow rate measurements of oil-water two-phase flows based on the developed apparatus. Full-range phase fraction can be obtained by the combination of the ECT sensor and the ERT sensor. By data fusion of differential pressures measured by venturi tube and the phase fraction, the total flow rate and single-phase flow rate can be calculated. Dynamic experiments were conducted on the multiphase flow loop in horizontal and vertical pipelines and at various flow rates.

  3. A Multicenter Randomized Noninferiority Trial Comparing GreenLight-XPS Laser Vaporization of the Prostate and Transurethral Resection of the Prostate for the Treatment of Benign Prostatic Obstruction: Two-yr Outcomes of the GOLIATH Study.

    PubMed

    Thomas, James A; Tubaro, Andrea; Barber, Neil; d'Ancona, Frank; Muir, Gordon; Witzsch, Ulrich; Grimm, Marc-Oliver; Benejam, Joan; Stolzenburg, Jens-Uwe; Riddick, Antony; Pahernik, Sascha; Roelink, Herman; Ameye, Filip; Saussine, Christian; Bruyère, Franck; Loidl, Wolfgang; Larner, Tim; Gogoi, Nirjan-Kumar; Hindley, Richard; Muschter, Rolf; Thorpe, Andrew; Shrotri, Nitin; Graham, Stuart; Hamann, Moritz; Miller, Kurt; Schostak, Martin; Capitán, Carlos; Knispel, Helmut; Bachmann, Alexander

    2016-01-01

    The GOLIATH study is a 2-yr trial comparing transurethral resection of prostate (TURP) to photoselective vaporization with the GreenLight XPS Laser System (GL-XPS) for the treatment of benign prostatic obstruction (BPO). Noninferiority of GL-XPS to TURP was demonstrated based on a 6-mo follow-up from the study. To determine whether treatment effects observed at 6 mo between GL-XPS and TURP was maintained at the 2-yr follow-up. Prospective randomized controlled trial at 29 centers in nine European countries involving 281 patients with BPO. Photoselective vaporization using the 180-W GreenLight GL-XPS or conventional (monopolar or bipolar) TURP. The primary outcome was the International Prostate Symptom Score for which a margin of three was used to evaluate the noninferiority of GL-XPS. Secondary outcomes included Qmax, prostate volume, prostate specific antigen, Overactive Bladder Questionnaire Short Form, International Consultation on Incontinence Questionnaire Short Form, occurrence of surgical retreatment, and freedom from complications. One hundred and thirty-six patients were treated using GL-XPS and 133 using TURP. Noninferiority of GL-XPS on International Prostate Symptom Score, Qmax, and freedom from complications was demonstrated at 6-mo and was sustained at 2-yr. The proportion of patients complication-free through 24-mo was 83.6% GL-XPS versus 78.9% TURP. Reductions in prostate volume and prostate specific antigen were similar in both arms and sustained over the course of the trial. Compared with the 1(st) yr of the study, very few adverse events or retreatments were reported in either arm. Treatment differences in the Overactive Bladder Questionnaire Short Form observed at 12-mo were not statistically significant at 24-mo. A limitation was that patients and treating physicians were not blinded to the therapy. Twenty-four-mo follow-up data demonstrated that GL-XPS provides a durable surgical option for the treatment of BPO that exhibits efficacy and safety outcomes similar to TURP. The long-term effectiveness and safety of GLP-XLS was similar to conventional TURP for the treatment of prostate enlargement. Copyright © 2015 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  4. Dynamics, OH distributions and UV emission of a gliding arc at various flow-rates investigated by optical measurements

    NASA Astrophysics Data System (ADS)

    Zhu, Jiajian; Sun, Zhiwei; Li, Zhongshan; Ehn, Andreas; Aldén, Marcus; Salewski, Mirko; Leipold, Frank; Kusano, Yukihiro

    2014-07-01

    We demonstrate a plasma discharge which is generated between two diverging electrodes and extended into a gliding arc in non-equilibrium condition by an air flow at atmospheric pressure. Effects of the air flow rates on the dynamics, ground-state OH distributions and spectral characterization of UV emission of the gliding arc were investigated by optical methods. High-speed photography was utilized to reveal flow-rate dependent dynamics such as ignitions, propagation, short-cutting events, extinctions and conversions of the discharge from glowtype to spark-type. Short-cutting events and ignitions occur more frequently at higher flow rates. The anchor points of the gliding arc are mostly steady at the top of the electrodes at lower flow rates whereas at higher flow rates they glide up along the electrodes most of the time. The afterglow of fully developed gliding arcs is observed to decay over hundreds of microseconds after being electronically short-cut by a newly ignited arc. The extinction time decreases with the increase of the flow rate. The frequency of the conversion of a discharge from glow-type to spark-type increases with the flow rate. Additionally, spatial distributions of ground-state OH were investigated using planar laser-induced fluorescence. The results show that the shape, height, intensity and thickness of ground-state OH distribution vary significantly with air flow rates. Finally, UV emission of the gliding arc is measured using optical emission spectroscopy and it is found that the emission intensity of NO γ (A-X), OH (A-X) and N2 (C-B) increase with the flow rates showing more characteristics of spark-type arcs. The observed phenomena indicate the significance of the interaction between local turbulence and the gliding arc.

  5. Method and system for measuring multiphase flow using multiple pressure differentials

    DOEpatents

    Fincke, James R.

    2001-01-01

    An improved method and system for measuring a multiphase flow in a pressure flow meter. An extended throat venturi is used and pressure of the multiphase flow is measured at three or more positions in the venturi, which define two or more pressure differentials in the flow conduit. The differential pressures are then used to calculate the mass flow of the gas phase, the total mass flow, and the liquid phase. The method for determining the mass flow of the high void fraction fluid flow and the gas flow includes certain steps. The first step is calculating a gas density for the gas flow. The next two steps are finding a normalized gas mass flow rate through the venturi and computing a gas mass flow rate. The following step is estimating the gas velocity in the venturi tube throat. The next step is calculating the pressure drop experienced by the gas-phase due to work performed by the gas phase in accelerating the liquid phase between the upstream pressure measuring point and the pressure measuring point in the venturi throat. Another step is estimating the liquid velocity in the venturi throat using the calculated pressure drop experienced by the gas-phase due to work performed by the gas phase. Then the friction is computed between the liquid phase and a wall in the venturi tube. Finally, the total mass flow rate based on measured pressure in the venturi throat is calculated, and the mass flow rate of the liquid phase is calculated from the difference of the total mass flow rate and the gas mass flow rate.

  6. Flow of High Internal Phase Ratio Emulsions through Pipes

    NASA Astrophysics Data System (ADS)

    Kostak, K.; Özsaygı, R.; Gündüz, I.; Yorgancıoǧlu, E.; Tekden, E.; Güzel, O.; Sadıklar, D.; Peker, S.; Helvacı, Ş. Ş.

    2015-04-01

    The flow behavior of W/O type of HIPRE stabilized by hydrogen bonds with a sugar (sorbitol) in the aqueous phase, was studied. Two groups of experiments were done in this work: The effect of wall shear stresses were investigated in flow through pipes of different diameters. For this end, HIPREs prestirred at constant rate for the same duration were used to obtain similar drop size distributions. Existence and extent of elongational viscosity were used as a probe to elucidate the effect of drop size distribution on the flow behavior: HIPREs prestirred for the same duration at different rates were subjected to flow through converging pipes. The experimental flow curves for flow through small cylindrical pipes indicated four different stages: 1) initial increase in the flow rate at low pressure difference, 2) subsequent decrease in the flow rate due to capillary flow, 3) pressure increase after reaching the minimum flow rate and 4) slip flow after a critical pressure difference. HIPREs with sufficient external liquid phase in the plateau borders can elongate during passage through converging pipes. In the absence of liquid stored in the plateau borders, the drops rupture during extension and slip flow takes place without elongation.

  7. Numerical Studies of a Supersonic Fluidic Diverter Actuator for Flow Control

    NASA Technical Reports Server (NTRS)

    Gokoglu, Suleyman A.; Kuczmarski, Maria A.; Culley, Dennis e.; Raghu, Surya

    2010-01-01

    The analysis of the internal flow structure and performance of a specific fluidic diverter actuator, previously studied by time-dependent numerical computations for subsonic flow, is extended to include operation with supersonic actuator exit velocities. The understanding will aid in the development of fluidic diverters with minimum pressure losses and advanced designs of flow control actuators. The self-induced oscillatory behavior of the flow is successfully predicted and the calculated oscillation frequencies with respect to flow rate have excellent agreement with our experimental measurements. The oscillation frequency increases with Mach number, but its dependence on flow rate changes from subsonic to transonic to supersonic regimes. The delay time for the initiation of oscillations depends on the flow rate and the acoustic speed in the gaseous medium for subsonic flow, but is unaffected by the flow rate for supersonic conditions

  8. Performance of three systems for warming intravenous fluids at different flow rates.

    PubMed

    Satoh, J; Yamakage, M; Wasaki, S I; Namiki, A

    2006-02-01

    This study compared the intravenous fluid warming capabilities of three systems at different flow rates. The devices studied were a water-bath warmer, a dry-heat plate warmer, and an intravenous fluid tube warmer Ambient temperature was controlled at 22 degrees to 24 degrees C. Normal saline (0.9% NaCl) at either room temperature (21 degrees to 23 degrees C) or at ice-cold temperature (3 degrees to 5 degrees C) was administered through each device at a range of flow rates (2 to 100 ml/min). To mimic clinical conditions, the temperature of the fluid was measured with thermocouples at the end of a one metre tube connected to the outflow of the warmer for the first two devices and at the end of the 1.2 m warming tubing for the intravenous fluid tube warmer The temperature of fluid delivered by the water bath warmer increased as the flow rate was increased up to 15 to 20 ml/min but decreased with greater flow rates. The temperature of the fluid delivered by the dry-heat plate warmer significantly increased as the flow rate was increased within the range tested (due to decreased cooling after leaving the device at higher flow rates). The temperature of fluid delivered by the intravenous fluid tube warmer did not depend on the flow rate up to 20 ml/min but significantly and fluid temperature-dependently decreased at higher flow rates (>30 ml/min). Under the conditions of our testing, the dry heat plate warmer delivered the highest temperature fluid at high flow rates.

  9. IN VITRO FLOW ANALYSIS OF NOVEL DOUBLE-CUTTING, OPEN-PORT, ULTRAHIGH-SPEED VITRECTOMY SYSTEMS.

    PubMed

    Zehetner, Claus; Moelgg, Marion; Bechrakis, Emmanouil; Linhart, Caroline; Bechrakis, Nikolaos E

    2017-10-09

    To analyze the performance and flow characteristics of novel double-cutting, open-port, 23-, 25-, and 27-gauge ultrahigh-speed vitrectomy systems. In vitro fluidic measurements were performed to assess the volumetric aspiration profiles of several vitrectomy systems in basic salt solution and egg white. Double-cutting open-port vitrectomy probes delivered stable aspiration flow rates that were less prone to flow variation affected by the cutting speed. Increase in cutting frequency to the maximum level resulted in flow reduction of less than 10% (0.0%-9.5%). Commercially available 23-, 25-, and 27-G double-cutting probes exhibited higher egg-white and basic salt solution flow rates at all evaluated cut rates, with aspirational efficiencies being 1.1 to 2.9 times the flow rates of standard single-blade vitrectomy probes of the same caliber at the maximum preset vacuum. The highest relative differences were observed at faster cut rates. The newly introduced double-cutting open-port vitrectomy probes delivered stable aspiration flow rates that were less prone to flow variation affected by the cutting speed. The fluidic principle of constant flow even at the highest cut rates and low vacuum levels might impact surgical strategies, especially when performing manipulations close to the retina.

  10. Fractionating power and outlet stream polydispersity in asymmetrical flow field-flow fractionation. Part II: programmed operation.

    PubMed

    Williams, P Stephen

    2017-01-01

    Asymmetrical flow field-flow fractionation (As-FlFFF) is a widely used technique for analyzing polydisperse nanoparticle and macromolecular samples. The programmed decay of cross flow rate is often employed. The interdependence of the cross flow rate through the membrane and the fluid flow along the channel length complicates the prediction of elution time and fractionating power. The theory for their calculation is presented. It is also confirmed for examples of exponential decay of cross flow rate with constant channel outlet flow rate that the residual sample polydispersity at the channel outlet is quite well approximated by the reciprocal of four times the fractionating power. Residual polydispersity is of importance when online MALS or DLS detection are used to extract quantitative information on particle size or molecular weight. The theory presented here provides a firm basis for the optimization of programmed flow conditions in As-FlFFF. Graphical abstract Channel outlet polydispersity remains significant following fractionation by As-FlFFF under conditions of programmed decay of cross flow rate.

  11. Evaluation of In Vitro and In Vivo Flow Rate Dependency of Budesonide/Formoterol Easyhaler®

    PubMed Central

    Malmberg, L. Pekka; Everard, Mark L.; Haikarainen, Jussi

    2014-01-01

    Abstract Background: The Easyhaler® (EH) device-metered dry powder inhaler containing budesonide and formoterol is being developed for asthma and chronic obstructive pulmonary disease (COPD). As a part of product optimization, a series of in vitro and in vivo studies on flow rate dependency were carried out. Methods: Inspiratory flow parameters via EH and Symbicort® Turbuhaler® (TH) inhalers were evaluated in 187 patients with asthma and COPD. The 10th, 50th, and 90th percentile flow rates achieved by patients were utilized to study in vitro flow rate dependency of budesonide/formoterol EH and Symbicort TH. In addition, an exploratory pharmacokinetic study on pulmonary deposition of active substances for budesonide/formoterol EH in healthy volunteers was performed. Results: Mean inspiratory flow rates through EH were 64 and 56 L/min in asthmatics and COPD patients, and through TH 79 and 72 L/min, respectively. Children with asthma had marginally lower PIF values than the adults. The inspiratory volumes were similar in all groups between the inhalers. Using weighted 10th, 50th, and 90th percentile flows the in vitro delivered doses (DDs) and fine particle doses (FPDs) for EH were rather independent of flow as 98% of the median flow DDs and 89%–93% of FPDs were delivered already at 10th percentile air flow. Using±15% limits, EH and TH had similar flow rate dependency profiles between 10th and 90th percentile flows. The pharmacokinetic study with budesonide/formoterol EH in healthy subjects (n=16) revealed a trend for a flow-dependent increase in lung deposition for both budesonide and formoterol. Conclusions: Comparable in vitro flow rate dependency between budesonide/formoterol EH and Symbicort TH was found using the range of clinically relevant flow rates. The results of the pharmacokinetic study were in accordance with the in vitro results showing only a trend of flow rate-dependant increase in lung deposition of active substances with EH. PMID:24978441

  12. Effects of oral health care on salivary flow rate in patients with type 2 diabetes: preliminary study.

    PubMed

    Ibayashi, Haruhisa; Nishiyama, Tomohiro; Tanaka, Masayuki; Pham, Truong-Minh; Yano, Junko; Sakai, Kazuyo; Kobayashi, Atsushi; Yakura, Naonori; Matsuda, Shinya

    2009-07-01

    The purpose of this study is to evaluate the effects of the authors' oral health care program on the stimulated whole salivary flow rate and buffer capacity before and after a 6-month intervention. The authors conducted the intervention study among 25 participants with diabetes. The salivary flow rate and buffer capacity were evaluated before and after this intervention. Overall, the results showed a significant increase in salivary flow rate and no significant change in buffer capacity. Also, it was likely that salivary flow rate significantly increased among patients with more than 20 remaining teeth and patients with well-controlled diabetes. The findings suggest that this program for type 2 diabetes led to an increase in the stimulated whole salivary flow rate.

  13. 40 CFR 1066.125 - Data updating, recording, and control.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... minimum recording frequency, such as for sample flow rates from a CVS that does not have a heat exchanger... exhaust flow rate from a CVS with a heat exchanger upstream of the flow measurement 1 Hz. 40 CFR 1065.545§ 1066.425 Diluted exhaust flow rate from a CVS without a heat exchanger upstream of the flow measurement...

  14. Electromagnetic Flow Meter Having a Driver Circuit Including a Current Transducer

    NASA Technical Reports Server (NTRS)

    Patel, Sandeep K. (Inventor); Karon, David M. (Inventor); Cushing, Vincent (Inventor)

    2014-01-01

    An electromagnetic flow meter (EMFM) accurately measures both the complete flow rate and the dynamically fluctuating flow rate of a fluid by applying a unipolar DC voltage to excitation coils for a predetermined period of time, measuring the electric potential at a pair of electrodes, determining a complete flow rate and independently measuring the dynamic flow rate during the "on" cycle of the DC excitation, and correcting the measurements for errors resulting from galvanic drift and other effects on the electric potential. The EMFM can also correct for effects from the excitation circuit induced during operation of the EMFM.

  15. Understanding the impact of flow rate and recycle on the conversion of a complex biorefinery stream using a flow-through microbial electrolysis cell

    DOE PAGES

    Lewis, Alex J.; Borole, Abhijeet P.

    2016-06-16

    We investigated the effect of flow rate and recycle on the conversion of a biomass-derived pyrolysis aqueous phase in amicrobial electrolysis cell (MEC) to demonstrate production of renewable hydrogen in biorefinery. A continuous MEC operation was investigated under one-pass and recycle conditions usingthe complex, biomass-derived, fermentable, mixed substrate feed at a constant concentration of 0.026 g/L,while testing flow rates ranging from 0.19 to 3.6 mL/min. This corresponds to an organic loading rate (OLR) of 0.54₋10 g/L-day. Mass transfer issues observed at low flow rates were alleviated using high flow rates.Increasing the flow rate to 3.6 mL/min (3.7 min HRT) duringmore » one-pass operation increased the hydrogen productivity 3-fold, but anode conversion efficiency (ACE) decreased from 57.9% to 9.9%. Recycle of the anode liquid helped to alleviate kinetic limitations and the ACE increased by 1.8-fold and the hydrogen productivity by 1.2-fold compared to the one-pass condition at the flow rate of 3.6 mL/min (10 g/L-d OLR). High COD removal was also achieved under recycle conditions, reaching 74.2 1.1%, with hydrogen production rate of 2.92 ± 0.51 L/L-day. This study demonstrates the advantages of combining faster flow rates with a recycle process to improve rate of hydrogen production from a switchgrass-derived stream in the biorefinery.« less

  16. Performance of high flow rate samplers for respirable particle collection.

    PubMed

    Lee, Taekhee; Kim, Seung Won; Chisholm, William P; Slaven, James; Harper, Martin

    2010-08-01

    The American Conference of Governmental Industrial hygienists (ACGIH) lowered the threshold limit value (TLV) for respirable crystalline silica (RCS) exposure from 0.05 to 0.025 mg m(-3) in 2006. For a working environment with an airborne dust concentration near this lowered TLV, the sample collected with current standard respirable aerosol samplers might not provide enough RCS for quantitative analysis. Adopting high flow rate sampling devices for respirable dust containing silica may provide a sufficient amount of RCS to be above the limit of quantification even for samples collected for less than full shift. The performances of three high flow rate respirable samplers (CIP10-R, GK2.69, and FSP10) have been evaluated in this study. Eleven different sizes of monodisperse aerosols of ammonium fluorescein were generated with a vibrating orifice aerosol generator in a calm air chamber in order to determine the sampling efficiency of each sampler. Aluminum oxide particles generated by a fluidized bed aerosol generator were used to test (i) the uniformity of a modified calm air chamber, (ii) the effect of loading on the sampling efficiency, and (iii) the performance of dust collection compared to lower flow rate cyclones in common use in the USA (10-mm nylon and Higgins-Dewell cyclones). The coefficient of variation for eight simultaneous samples in the modified calm air chamber ranged from 1.9 to 6.1% for triplicate measures of three different aerosols. The 50% cutoff size ((50)d(ae)) of the high flow rate samplers operated at the flow rates recommended by manufacturers were determined as 4.7, 4.1, and 4.8 microm for CIP10-R, GK2.69, and FSP10, respectively. The mass concentration ratio of the high flow rate samplers to the low flow rate cyclones decreased with decreasing mass median aerodynamic diameter (MMAD) and high flow rate samplers collected more dust than low flow rate samplers by a range of 2-11 times based on gravimetric analysis. Dust loading inside the high flow rate samplers does not appear to affect the particle separation in either FSP10 or GK2.69. The high flow rate samplers overestimated compared to the International Standards Organization/Comité Européen de Normalisation/ACGIH respirable convention [up to 40% at large MMAD (27.5 microm)] and could provide overestimated exposure data with the current flow rates. However, both cyclones appeared to be able to provide relatively unbiased assessments of RCS when their flow rates were adjusted.

  17. Performance of High Flow Rate Samplers for Respirable Particle Collection

    PubMed Central

    Lee, Taekhee; Kim, Seung Won; Chisholm, William P.; Slaven, James; Harper, Martin

    2010-01-01

    The American Conference of Governmental Industrial hygienists (ACGIH) lowered the threshold limit value (TLV) for respirable crystalline silica (RCS) exposure from 0.05 to 0.025 mg m−3 in 2006. For a working environment with an airborne dust concentration near this lowered TLV, the sample collected with current standard respirable aerosol samplers might not provide enough RCS for quantitative analysis. Adopting high flow rate sampling devices for respirable dust containing silica may provide a sufficient amount of RCS to be above the limit of quantification even for samples collected for less than full shift. The performances of three high flow rate respirable samplers (CIP10-R, GK2.69, and FSP10) have been evaluated in this study. Eleven different sizes of monodisperse aerosols of ammonium fluorescein were generated with a vibrating orifice aerosol generator in a calm air chamber in order to determine the sampling efficiency of each sampler. Aluminum oxide particles generated by a fluidized bed aerosol generator were used to test (i) the uniformity of a modified calm air chamber, (ii) the effect of loading on the sampling efficiency, and (iii) the performance of dust collection compared to lower flow rate cyclones in common use in the USA (10-mm nylon and Higgins–Dewell cyclones). The coefficient of variation for eight simultaneous samples in the modified calm air chamber ranged from 1.9 to 6.1% for triplicate measures of three different aerosols. The 50% cutoff size (50dae) of the high flow rate samplers operated at the flow rates recommended by manufacturers were determined as 4.7, 4.1, and 4.8 μm for CIP10-R, GK2.69, and FSP10, respectively. The mass concentration ratio of the high flow rate samplers to the low flow rate cyclones decreased with decreasing mass median aerodynamic diameter (MMAD) and high flow rate samplers collected more dust than low flow rate samplers by a range of 2–11 times based on gravimetric analysis. Dust loading inside the high flow rate samplers does not appear to affect the particle separation in either FSP10 or GK2.69. The high flow rate samplers overestimated compared to the International Standards Organization/Comité Européen de Normalisation/ACGIH respirable convention [up to 40% at large MMAD (27.5 μm)] and could provide overestimated exposure data with the current flow rates. However, both cyclones appeared to be able to provide relatively unbiased assessments of RCS when their flow rates were adjusted. PMID:20660144

  18. Flow visualization and acoustic consequences of the air moving through a static model of the human larynx.

    PubMed

    Kucinschi, Bogdan R; Scherer, Ronald C; DeWitt, Kenneth J; Ng, Terry T M

    2006-06-01

    Flow visualization with smoke particles illuminated by a laser sheet was used to obtain a qualitative description of the air flow structures through a dynamically similar 7.5x symmetric static scale model of the human larynx (divergence angle of 10 deg, minimal diameter of 0.04 cm real life). The acoustic level downstream of the vocal folds was measured by using a condenser microphone. False vocal folds (FVFs) were included. In general, the glottal flow was laminar and bistable. The glottal jet curvature increased with flow rate and decreased with the presence of the FVFs. The glottal exit flow for the lowest flow rate showed a curved jet which remained laminar for all geometries. For the higher flow rates, the jet flow patterns exiting the glottis showed a laminar jet core, transitioning to vortical structures, and leading spatially to turbulent dissipation. This structure was shortened and tightened with an increase in flow rate. The narrow FVF gap lengthened the flow structure and reduced jet curvature via acceleration of the flow. These results suggest that laryngeal flow resistance and the complex jet flow structure exiting the glottis are highly affected by flow rate and the presence of the false vocal folds. Acoustic consequences are discussed in terms of the quadrupole- and dipole-type sound sources due to ordered flow structures.

  19. Quantification of the transient mass flow rate in a simplex swirl injector

    NASA Astrophysics Data System (ADS)

    Khil, Taeock; Kim, Sunghyuk; Cho, Seongho; Yoon, Youngbin

    2009-07-01

    When a heat release and acoustic pressure fluctuations are generated in a combustor by irregular and local combustions, these fluctuations affect the mass flow rate of the propellants injected through the injectors. In addition, variations of the mass flow rate caused by these fluctuations bring about irregular combustion, which is associated with combustion instability, so it is very important to identify a mass variation through the pressure fluctuation on the injector and to investigate its transfer function. Therefore, quantification of the variation of the mass flow rate generated in a simplex swirl injector via the injection pressure fluctuation was the subject of an initial study. To acquire the transient mass flow rate in the orifice with time, the axial velocity of flows and the liquid film thickness in the orifice were measured. The axial velocity was acquired through a theoretical approach after measuring the pressure in the orifice. In an effort to understand the flow area in the orifice, the liquid film thickness was measured by an electric conductance method. In the results, the mass flow rate calculated from the axial velocity and the liquid film thickness measured by the electric conductance method in the orifice was in good agreement with the mass flow rate acquired by the direct measuring method in a small error range within 1% in the steady state and within 4% for the average mass flow rate in a pulsated state. Also, the amplitude (gain) of the mass flow rate acquired by the proposed direct measuring method was confirmed using the PLLIF technique in the low pressure fluctuation frequency ranges with an error under 6%. This study shows that our proposed method can be used to measure the mass flow rate not only in the steady state but also in the unsteady state (or the pulsated state). Moreover, this method shows very high accuracy based on the experimental results.

  20. Effect of flow velocity on erosion-corrosion behaviour of QSn6 alloy

    NASA Astrophysics Data System (ADS)

    Huang, Weijiu; Zhou, Yongtao; Wang, Zhenguo; Li, Zhijun; Zheng, Ziqing

    2018-05-01

    The erosion-corrosion behaviour of QSn6 alloy used as propellers in marine environment was evaluated by erosion-corrosion experiments with/without cathodic protection, electrochemical tests and scanning electron microscope (SEM) observations. The analysis was focused on the effect of flow velocity. The dynamic polarization curves showed that the corrosion rate of the QSn6 alloy increased as the flow velocity increased, due to the protective surface film removal at higher velocities. The lowest corrosion current densities of 1.26 × 10‑4 A cm‑2 was obtained at the flow velocity of 7 m s‑1. Because of the higher particle kinetic energies at higher flow velocity, the mass loss rate of the QSn6 alloy increased as the flow velocity increased. The mass loss rate with cathodic protection was lower than that without cathodic protection under the same conditions. Also, the lowest mass loss rate of 0.7 g m‑2 · h‑1 was acquired at the flow velocity of 7 m s‑1 with cathodic protection. However, the increase rate of corrosion rate and mass loss were decreased with increasing the flow velocity. Through observation the SEM morphologies of the worn surfaces, the main wear mechanism was ploughing with/without cathodic protection. The removal rates of the QSn6 alloy increased as the flow velocity increased in both pure erosion and erosion-corrosion, whereas the erosion and corrosion intensified each other. At the flow velocity of 7 m s‑1, the synergy rate (ΔW) exceeded by 5 times the erosion rate (Wwear). Through establishment and observation the erosion-corrosion mechanism map, the erosion-corrosion was the dominant regime in the study due to the contribution of erosion on the mass loss rate exceeded the corrosion contribution. The QSn6 alloy with cathodic protection is feasible as propellers, there are higher security at lower flow velocity, such as the flow velocity of 7 m s‑1 in the paper.

  1. Scram signal generator

    DOEpatents

    Johanson, Edward W.; Simms, Richard

    1981-01-01

    A scram signal generating circuit for nuclear reactor installations monitors a flow signal representing the flow rate of the liquid sodium coolant which is circulated through the reactor, and initiates reactor shutdown for a rapid variation in the flow signal, indicative of fuel motion. The scram signal generating circuit includes a long-term drift compensation circuit which processes the flow signal and generates an output signal representing the flow rate of the coolant. The output signal remains substantially unchanged for small variations in the flow signal, attributable to long term drift in the flow rate, but a rapid change in the flow signal, indicative of a fast flow variation, causes a corresponding change in the output signal. A comparator circuit compares the output signal with a reference signal, representing a given percentage of the steady state flow rate of the coolant, and generates a scram signal to initiate reactor shutdown when the output signal equals the reference signal.

  2. Scram signal generator

    DOEpatents

    Johanson, E.W.; Simms, R.

    A scram signal generating circuit for nuclear reactor installations monitors a flow signal representing the flow rate of the liquid sodium coolant which is circulated through the reactor, and initiates reactor shutdown for a rapid variation in the flow signal, indicative of fuel motion. The scram signal generating circuit includes a long-term drift compensation circuit which processes the flow signal and generates an output signal representing the flow rate of the coolant. The output signal remains substantially unchanged for small variations in the flow signal, attributable to long term drift in the flow rate, but a rapid change in the flow signal, indicative of a fast flow variation, causes a corresponding change in the output signal. A comparator circuit compares the output signal with a reference signal, representing a given percentage of the steady state flow rate of the coolant, and generates a scram signal to initiate reactor shutdown when the output signal equals the reference signal.

  3. Dialysate Flow Rate and Delivered Kt/Vurea for Dialyzers with Enhanced Dialysate Flow Distribution

    PubMed Central

    Idoux, John W.; Hamdan, Hiba; Ouseph, Rosemary; Depner, Thomas A.; Golper, Thomas A.

    2011-01-01

    Summary Background and objectives Previous in vitro and clinical studies showed that the urea mass transfer-area coefficient (KoA) increased with increasing dialysate flow rate. This observation led to increased dialysate flow rates in an attempt to maximize the delivered dose of dialysis (Kt/Vurea). Recently, we showed that urea KoA was independent of dialysate flow rate in the range 500 to 800 ml/min for dialyzers incorporating features to enhance dialysate flow distribution, suggesting that increasing the dialysate flow rate with such dialyzers would not significantly increase delivered Kt/Vurea. Design, setting, participants, & measurements We performed a multi-center randomized clinical trial to compare delivered Kt/Vurea at dialysate flow rates of 600 and 800 ml/min in 42 patients. All other aspects of the dialysis prescription, including treatment time, blood flow rate, and dialyzer, were kept constant for a given patient. Delivered single-pool and equilibrated Kt/Vurea were calculated from pre- and postdialysis plasma urea concentrations, and ionic Kt/V was determined from serial measurements of ionic dialysance made throughout each treatment. Results Delivered Kt/Vurea differed between centers; however, the difference in Kt/Vurea between dialysate flow rates of 800 and 600 ml/min was NS by any measure (95% confidence intervals of −0.064 to 0.024 for single-pool Kt/Vurea, −0.051 to 0.023 for equilibrated Kt/Vurea, and −0.029 to 0.099 for ionic Kt/V). Conclusions These data suggest that increasing the dialysate flow rate beyond 600 ml/min for these dialyzers offers no benefit in terms of delivered Kt/Vurea. PMID:21799145

  4. Development and evaluation of virtual refrigerant mass flow sensors for fault detection and diagnostics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Woohyun; Braun, J.

    Refrigerant mass flow rate is an important measurement for monitoring equipment performance and enabling fault detection and diagnostics. However, a traditional mass flow meter is expensive to purchase and install. A virtual refrigerant mass flow sensor (VRMF) uses a mathematical model to estimate flow rate using low-cost measurements and can potentially be implemented at low cost. This study evaluates three VRMFs for estimating refrigerant mass flow rate. The first model uses a compressor map that relates refrigerant flow rate to measurements of inlet and outlet pressure, and inlet temperature measurements. The second model uses an energy-balance method on the compressormore » that uses a compressor map for power consumption, which is relatively independent of compressor faults that influence mass flow rate. The third model is developed using an empirical correlation for an electronic expansion valve (EEV) based on an orifice equation. The three VRMFs are shown to work well in estimating refrigerant mass flow rate for various systems under fault-free conditions with less than 5% RMS error. Each of the three mass flow rate estimates can be utilized to diagnose and track the following faults: 1) loss of compressor performance, 2) fouled condenser or evaporator filter, 3) faulty expansion device, respectively. For example, a compressor refrigerant flow map model only provides an accurate estimation when the compressor operates normally. When a compressor is not delivering the expected flow due to a leaky suction or discharge valve or other internal fault, the energy-balance or EEV model can provide accurate flow estimates. In this paper, the flow differences provide an indication of loss of compressor performance and can be used for fault detection and diagnostics.« less

  5. Quantification aspects of constant pressure (ultra) high pressure liquid chromatography using mass-sensitive detectors with a nebulizing interface.

    PubMed

    Verstraeten, M; Broeckhoven, K; Lynen, F; Choikhet, K; Landt, K; Dittmann, M; Witt, K; Sandra, P; Desmet, G

    2013-01-25

    The present contribution investigates the quantitation aspects of mass-sensitive detectors with nebulizing interface (ESI-MSD, ELSD, CAD) in the constant pressure gradient elution mode. In this operation mode, the pressure is controlled and maintained at a set value and the liquid flow rate will vary according to the inverse mobile phase viscosity. As the pressure is continuously kept at the allowable maximum during the entire gradient run, the average liquid flow rate is higher compared to that in the conventional constant flow rate operation mode, thus shortening the analysis time. The following three mass-sensitive detectors were investigated: mass spectrometry detector (MS), evaporative light scattering detector (ELSD) and charged aerosol detector (CAD) and a wide variety of samples (phenones, polyaromatic hydrocarbons, wine, cocoa butter) has been considered. It was found that the nebulizing efficiency of the LC-interfaces of the three detectors under consideration changes with the increasing liquid flow rate. For the MS, the increasing flow rate leads to a lower peak area whereas for the ELSD the peak area increases compared to the constant flow rate mode. The peak area obtained with a CAD is rather insensitive to the liquid flow rate. The reproducibility of the peak area remains similar in both modes, although variation in system permeability compromises the 'long-term' reproducibility. This problem can however be overcome by running a flow rate program with an optimized flow rate and composition profile obtained from the constant pressure mode. In this case, the quantification remains reproducibile, despite any occuring variations of the system permeability. Furthermore, the same fragmentation pattern (MS) has been found in the constant pressure mode compared to the customary constant flow rate mode. Copyright © 2012 Elsevier B.V. All rights reserved.

  6. Fluctuations of wormlike micelle fluids in capillary flow

    NASA Astrophysics Data System (ADS)

    Salipante, Paul; Meek, Stephen; Hudson, Steven; Polymers; Complex Fluids Group Team

    2017-11-01

    We investigate the effect of entrance geometry on the flow stability of wormlike micelles solutions in capillary flow. These solutions exhibit strong shear thinning behavior resulting from micelle breakage and have been observed to undergo large flow rate fluctuations. We investigate these fluctuations using simultaneous measurements of flow rate and pressure drop across a capillary, and we adjust entrance geometry. With a tapered constriction, we observe large persistent fluctuations above a critical flow rate, characterized by rapid decreases in the pressure drop with corresponding increase in flow rate followed by a period of recovery where pressure increases and flow rate decreases. Flow field observations in the tapered entrance show large flow circulations. An abrupt contraction produces smaller transient fluidized jets forming upstream of the constriction and the magnitude of the fluctuations are significantly diminished. The effect of fluid properties is studied by comparing the magnitude and timescales of the fluctuations for surfactant systems with different relaxation times. The onset of fluctuations is compared to a criterion for the onset of elastic instabilities and the magnitude is compared to estimates for changes in channel resistance. NIST on a Chip.

  7. Mixed Convection Flow in Horizontal CVD Reactors

    NASA Astrophysics Data System (ADS)

    Chiu, Wilson K. S.; Richards, Cristy J.; Jaluria, Yogesh

    1998-11-01

    Increasing demands for high quality films and production rates are challenging current Chemical Vapor Deposition (CVD) technology. Since film quality and deposition rates are strongly dependent on gas flow and heat transfer (W.K.S. Chiu and Y. Jaluria, ASME HTD-Vol. 347, pp. 293-311, 1997.), process improvement is obtained through the study of mixed convection flow and temperature distribution in a CVD reactor. Experimental results are presented for a CVD chamber with a horizontal or inclined resistance heated susceptor. Vaporized glycol solution illuminated by a light sheet is used for flow visualization. Temperature measurements are obtained by inserting thermocouple probes into the gas stream or embedding probes into the reactor walls. Flow visualization and temperature measurements show predominantly two dimensional flow and temperature distributions along the streamwise direction under forced convection conditions. Natural convection dominates under large heating rates and low flow rates. Over the range of parameters studied, several distinct flow regimes, characterized by instability, separation, and turbulence, are evident. Different flow regimes alter the flow pattern and temperature distribution, and in consequence, significantly modify deposition rates and uniformity.

  8. Fluid structure interaction dynamic analysis of a mixed-flow waterjet pump

    NASA Astrophysics Data System (ADS)

    Pan, X. W.; Y Pan, Z.; Huang, D.; Shen, Z. H.

    2013-12-01

    In order to avoid resonance of a mixed-flow waterjet pump at run time and calculate the stress and deformation of the pump rotor in the flow field, a one-way fluid structure interaction method was applied to simulate the pump rotor using ANSYS CFX and ANSYS Workbench software. The natural frequencies and mode shapes of the pump rotor in the air and in the flow field were analyzed, and the stress and deformation of the impeller were obtained at different flow rates. The obtained numerical results indicated that the mode shapes were similar both in the air and in the flow field, but the pump rotor's natural frequency in the flow field was slightly smaller than that in the air; the difference of the pump rotor's natural frequency varied lightly at different flow rates, and all frequencies at different flow rates were higher than the safe frequency, the pump rotor under the effect of prestress rate did not occur resonance; The maximum stress was on the blade near the hub and the maximum deformation on the blade tip at different flow rates.

  9. The measurements of water flow rates in the straight microchannel based on the scanning micro-PIV technique

    NASA Astrophysics Data System (ADS)

    Wang, H. L.; Han, W.; Xu, M.

    2011-12-01

    Measurement of the water flow rate in microchannel has been one of the hottest points in the applications of microfluidics, medical, biological, chemical analyses and so on. In this study, the scanning microscale particle image velocimetry (scanning micro-PIV) technique is used for the measurements of water flow rates in a straight microchannel of 200μm width and 60μm depth under the standard flow rates ranging from 2.481μL/min to 8.269μL/min. The main effort of this measurement technique is to obtain three-dimensional velocity distribution on the cross sections of microchannel by measuring velocities of the different fluid layers along the out-of-plane direction in the microchannel, so the water flow rates can be evaluated from the discrete surface integral of velocities on the cross section. At the same time, the three-dimensional velocity fields in the measured microchannel are simulated numerically using the FLUENT software in order to verify the velocity accuracy of measurement results. The results show that the experimental values of flow rates are well consistent to the standard flow rates input by the syringe pump and the compared results between numerical simulation and experiment are consistent fundamentally. This study indicates that the micro-flow rate evaluated from three-dimensional velocity by the scanning micro-PIV technique is a promising method for the micro-flow rate research.

  10. Flow rate-pressure drop relation for deformable shallow microfluidic channels

    NASA Astrophysics Data System (ADS)

    Christov, Ivan C.; Cognet, Vincent; Shidhore, Tanmay C.; Stone, Howard A.

    2018-04-01

    Laminar flow in devices fabricated from soft materials causes deformation of the passage geometry, which affects the flow rate--pressure drop relation. For a given pressure drop, in channels with narrow rectangular cross-section, the flow rate varies as the cube of the channel height, so deformation can produce significant quantitative effects, including nonlinear dependence on the pressure drop [{Gervais, T., El-Ali, J., G\\"unther, A. \\& Jensen, K.\\ F.}\\ 2006 Flow-induced deformation of shallow microfluidic channels.\\ \\textit{Lab Chip} \\textbf{6}, 500--507]. Gervais et. al. proposed a successful model of the deformation-induced change in the flow rate by heuristically coupling a Hookean elastic response with the lubrication approximation for Stokes flow. However, their model contains a fitting parameter that must be found for each channel shape by performing an experiment. We present a perturbation approach for the flow rate--pressure drop relation in a shallow deformable microchannel using the theory of isotropic quasi-static plate bending and the Stokes equations under a lubrication approximation (specifically, the ratio of the channel's height to its width and of the channel's height to its length are both assumed small). Our result contains no free parameters and confirms Gervais et. al.'s observation that the flow rate is a quartic polynomial of the pressure drop. The derived flow rate--pressure drop relation compares favorably with experimental measurements.

  11. Effects of chewing rate and reactive hyperemia on blood flow in denture-supporting mucosa during simulated chewing.

    PubMed

    Ogino, Takamichi; Ueda, Takayuki; Ogami, Koichiro; Koike, Takashi; Sakurai, Kaoru

    2017-01-01

    We examined how chewing rate and the extent of reactive hyperemia affect the blood flow in denture-supporting mucosa during chewing. The left palatal mucosa was loaded under conditions of simulated chewing or simulated clenching for 30s, and the blood flow during loading was recorded. We compared the relative blood flow during loading under conditions that recreated different chewing rates by combining duration of chewing cycle (DCC) and occlusal time (OT): fast chewing group, typical chewing group, slow chewing group and clenching group. The relationship between relative blood flow during simulated chewing and the extent of reactive hyperemia was also analyzed. When comparing the different chewing rate, the relative blood flow was highest in fast chewing rate, followed by typical chewing rate and slow chewing rate. Accordingly, we suggest that fast chewing increases the blood flow more than typical chewing or slow chewing. There was a significant correlation between the amount of blood flow during simulated chewing and the extent of reactive hyperemia. Within the limitations of this study, we concluded that slow chewing induced less blood flow than typical or fast chewing in denture-supporting mucosa and that people with less reactive hyperemia had less blood flow in denture-supporting mucosa during chewing. Copyright © 2016 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  12. Numerical investigation and thermodynamic analysis of the effect of electrolyte flow rate on performance of all vanadium redox flow batteries

    NASA Astrophysics Data System (ADS)

    Khazaeli, Ali; Vatani, Ali; Tahouni, Nassim; Panjeshahi, Mohammad Hassan

    2015-10-01

    In flow batteries, electrolyte flow rate plays a crucial role on the minimizing mass transfer polarization which is at the compensation of higher pressure drop. In this work, a two-dimensional numerical method is applied to investigate the effect of electrolyte flow rate on cell voltage, maximum depth of discharge and pressure drop a six-cell stack of VRFB. The results show that during the discharge process, increasing electrolyte flow rate can raise the voltage of each cell up to 50 mV on average. Moreover, the maximum depth of discharge dramatically increases with electrolyte flow rate. On the other hand, the pressure drop also positively correlates with electrolyte flow rate. In order to investigate all these effects simultaneously, average energy and exergy efficiencies are introduced in this study for the transient process of VRFB. These efficiencies give insight into choosing an appropriate strategy for the electrolyte flow rate. Finally, the energy efficiency of electricity storage using VRFB is investigated and compared with other energy storage systems. The results illustrate that this kind of battery has at least 61% storage efficiency based on the second law of thermodynamics, which is considerably higher than that of their counterparts.

  13. Impacts of changing hydrology on permanent gully growth: experimental results

    NASA Astrophysics Data System (ADS)

    Day, Stephanie S.; Gran, Karen B.; Paola, Chris

    2018-06-01

    Permanent gullies grow through head cut propagation in response to overland flow coupled with incision and widening in the channel bottom leading to hillslope failures. Altered hydrology can impact the rate at which permanent gullies grow by changing head cut propagation, channel incision, and channel widening rates. Using a set of small physical experiments, we tested how changing overland flow rates and flow volumes alter the total volume of erosion and resulting gully morphology. Permanent gullies were modeled as both detachment-limited and transport-limited systems, using two different substrates with varying cohesion. In both cases, the erosion rate varied linearly with water discharge, such that the volume of sediment eroded was a function not of flow rate, but of total water volume. This implies that efforts to reduce peak flow rates alone without addressing flow volumes entering gully systems may not reduce erosion. The documented response in these experiments is not typical when compared to larger preexisting channels where higher flow rates result in greater erosion through nonlinear relationships between water discharge and sediment discharge. Permanent gullies do not respond like preexisting channels because channel slope remains a free parameter and can adjust relatively quickly in response to changing flows.

  14. Optical spectral sweep comb liquid flow rate sensor.

    PubMed

    Shen, Changyu; Lian, Xiaokang; Kavungal, Vishnu; Zhong, Chuan; Liu, Dejun; Semenova, Yuliya; Farrell, Gerald; Albert, Jacques; Donegan, John F

    2018-02-15

    In microfluidic chip applications, the flow rate plays an important role. Here we propose a simple liquid flow rate sensor by using a tilted fiber Bragg grating (TFBG) as the sensing element. As the water flows in the vicinity of the TFBG along the fiber axis direction, the TFBG's spectrum changes due to its contact with water. By comparing the time-swept spectra of the TFBG in water to that of the TFBG with water flowing over it, a spectral sweep comb was formed, and the flow rate can be detected by selecting a suitable sweeping frequency. The proposed sensor has a high Q-value of over 17,000 for the lower rate and a large detectable range from 0.0058 mm/s to 3.2 mm/s. And the calculated corresponding lower detectable flow rate of 0.03 nL/s is 3 orders magnitude better than that of the current fiber flowmeter. Meanwhile, the proposed sensor has the temperature self-compensation function for the variation of the external temperature. We believe that this simple configuration will open a research direction of the TFBG-deriving theory and configuration for lower flow rate measurements for microfluidic chip applications.

  15. A method of predicting flow rates required to achieve anti-icing performance with a porous leading edge ice protection system

    NASA Technical Reports Server (NTRS)

    Kohlman, D. L.; Albright, A. E.

    1983-01-01

    An analytical method was developed for predicting minimum flow rates required to provide anti-ice protection with a porous leading edge fluid ice protection system. The predicted flow rates compare with an average error of less than 10 percent to six experimentally determined flow rates from tests in the NASA Icing Research Tunnel on a general aviation wing section.

  16. Rootless shield and perched lava pond collapses at Kīlauea Volcano, Hawai'i

    USGS Publications Warehouse

    Patrick, Matthew R.; Orr, Tim R.

    2012-01-01

    Effusion rate is a primary measurement used to judge the expected advance rate, length, and hazard potential of lava flows. At basaltic volcanoes, the rapid draining of lava stored in rootless shields and perched ponds can produce lava flows with much higher local effusion rates and advance velocities than would be expected based on the effusion rate at the vent. For several months in 2007–2008, lava stored in a series of perched ponds and rootless shields on Kīlauea Volcano, Hawai'i, was released episodically to produce fast-moving 'a'ā lava flows. Several of these lava flows approached Royal Gardens subdivision and threatened the safety of remaining residents. Using time-lapse image measurements, we show that the initial time-averaged discharge rate for one collapse-triggered lava flow was approximately eight times greater than the effusion rate at the vent. Though short-lived, the collapse-triggered 'a'ā lava flows had average advance rates approximately 45 times greater than that of the pāhoehoe flow field from which they were sourced. The high advance rates of the collapse-triggered lava flows demonstrates that recognition of lava accumulating in ponds and shields, which may be stored in a cryptic manner, is vital for accurately assessing short-term hazards at basaltic volcanoes.

  17. Controlled field evaluation of water flow rate effects on sampling polar organic compounds using polar organic chemical integrative samplers.

    PubMed

    Li, Hongxia; Vermeirssen, Etiënne L M; Helm, Paul A; Metcalfe, Chris D

    2010-11-01

    The uptake of polar organic contaminants into polar organic chemical integrative samplers (POCIS) varies with environmental factors, such as water flow rate. To evaluate the influence of water flow rate on the uptake of contaminants into POCIS, flow-controlled field experiments were conducted with POCIS deployed in channel systems through which treated sewage effluent flowed at rates between 2.6 and 37 cm/s. Both pharmaceutical POCIS and pesticide POCIS were exposed to effluent for 21 d and evaluated for uptake of pharmaceuticals and personal care products (PPCPs) and endocrine disrupting substances (EDS). The pesticide POCIS had higher uptake rates for PPCPs and EDS than the pharmaceutical POCIS, but there are some practical advantages to using pharmaceutical POCIS. The uptake of contaminants into POCIS increased with flow rate, but these effects were relatively small (i.e., less than twofold) for most of the test compounds. There was no relationship observed between the hydrophobicity (log octanol/water partition coefficient, log K(OW)) of model compounds and the effects of flow rate on the uptake kinetics by POCIS. These data indicate that water flow rate has a relatively minor influence on the accumulation of PPCPs and EDS into POCIS. © 2010 SETAC.

  18. Molecular simulation of flow-enhanced nucleation in n-eicosane melts under steady shear and uniaxial extension.

    PubMed

    Nicholson, David A; Rutledge, Gregory C

    2016-12-28

    Non-equilibrium molecular dynamics is used to study crystal nucleation of n-eicosane under planar shear and, for the first time, uniaxial extension. A method of analysis based on the mean first-passage time is applied to the simulation results in order to determine the effect of the applied flow field type and strain rate on the steady-state nucleation rate and a characteristic growth rate, as well as the effects on kinetic parameters associated with nucleation: the free energy barrier, critical nucleus size, and monomer attachment pre-factor. The onset of flow-enhanced nucleation (FEN) occurs at a smaller critical strain rate in extension as compared to shear. For strain rates larger than the critical rate, a rapid increase in the nucleation rate is accompanied by decreases in the free energy barrier and critical nucleus size, as well as an increase in chain extension. These observations accord with a mechanism in which FEN is caused by an increase in the driving force for crystallization due to flow-induced entropy reduction. At high applied strain rates, the free energy barrier, critical nucleus size, and degree of stretching saturate, while the monomer attachment pre-factor and degree of orientational order increase steadily. This trend is indicative of a significant diffusive contribution to the nucleation rate under intense flows that is correlated with the degree of global orientational order in a nucleating system. Both flow fields give similar results for all kinetic quantities with respect to the reduced strain rate, which we define as the ratio of the applied strain rate to the critical rate. The characteristic growth rate increases with increasing strain rate, and shows a correspondence with the nucleation rate that does not depend on the type of flow field applied. Additionally, a structural analysis of the crystalline clusters indicates that the flow field suppresses the compaction and crystalline ordering of clusters, leading to the formation of large articulated clusters under strong flow fields, and compact well-ordered clusters under weak flow fields.

  19. Experimental Parameters for Wax Modeling of the Deccan Traps Flood Basalt Province

    NASA Astrophysics Data System (ADS)

    Rader, E. L.; Vanderkluysen, L.; Clarke, A. B.

    2015-12-01

    The Deccan Traps consist of ~1,000,000 km3 of predominantly tholeiitic basaltic lava flows, which cover the western Indian subcontinent. Their eruption occurred over a ~1-3 million year period overlapping with the Cretaceous-Paleogene (K-Pg) boundary and, hence, has been implicated in one of the most significant extinction events in the history of the planet. The extent of environmental impacts caused by flood basalt eruptions is thought to be related, in part, to the amount, species, and timescales of volcanic gases released. Therefore, constraining the effusion rate of Deccan Traps lava flows is fundamental to understanding the K-Pg extinction event. Previous field and experimental work with polyethylene glycol (PEG) wax has shown that effusion rate is a primary factor controlling flow morphology. While sinuous flows and lava domes have been successfully recreated with PEG wax, the two most common morphologies seen in the Deccan Traps (compound and inflated sheet lobes) have not. We used heated PEG-400 wax injected into a tank of chilled water with a peristaltic pump to form experimental eruptions with high flow rate and low viscosity to replicate inflated flow lobes, and low flow rate with higher viscosity for compound flows. Unlike previous experiments, flow rate was varied during a single experiment to examine the effect on flow morphology. The Psi value is used as a scaling parameter to estimate effusion rates for compound and 'simple' inflated flows in the Deccan Traps. When combined with field work for volume estimates of the two flow types, these experiments will provide the best constraint on eruption rates to date.

  20. An electronic flow control system for a variable-rate tree sprayer

    USDA-ARS?s Scientific Manuscript database

    Precise modulation of nozzle flow rates is a critical measure to achieve variable-rate spray applications. An electronic flow rate control system accommodating with microprocessors and pulse width modulation (PWM) controlled solenoid valves was designed to manipulate the output of spray nozzles inde...

  1. 40 CFR 60.85 - Test methods and procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... flow rate of the effluent gas, dscm/hr (dscf/hr). P=production rate of 100 percent H2SO4, metric ton/hr... the volumetric flow rate and production rate: (i) The integrated technique of Method 3 is used to... mist and SO2 concentrations (C's) and the volumetric flow rate (Qsd) of the effluent gas. The moisture...

  2. Nitrate Removal Rates in Denitrifying Bioreactors During Storm Flows

    NASA Astrophysics Data System (ADS)

    Pluer, W.; Walter, T.

    2017-12-01

    Field denitrifying bioreactors are designed to reduce excess nitrate (NO3-) pollution in runoff from agricultural fields. Field bioreactors saturate organic matter to create conditions that facilitate microbial denitrification. Prior studies using steady flow in lab-scale bioreactors showed that a hydraulic retention time (HRT) between 4 and 10 hours was optimal for reducing NO3- loads. However, during storm-induced events, flow rate and actual HRT fluctuate. These fluctuations have the potential to disrupt the system in significant ways that are not captured by the idealized steady-flow HRT models. The goal of this study was to investigate removal rate during dynamic storm flows of variable rates and durations. Our results indicate that storm peak flow and duration were not significant controlling variables. Instead, we found high correlations (p=0.004) in average removal rates between bioreactors displaying a predominantly uniform flow pattern compared with bioreactors that exhibited preferential flow (24.4 and 21.4 g N m-3 d-1, respectively). This suggests that the internal flow patterns are a more significant driver of removal rate than external factors of the storm hydrograph. Designing for flow patterns in addition to theoretical HRT will facilitate complete mixing within the bioreactors. This will help maximize excess NO3- removal during large storm-induced runoff events.

  3. Selective adsorption of Pt ions from chloride solutions obtained by leaching chlorinated spent automotive catalysts on ion exchange resin Diaion WA21J.

    PubMed

    Shen, Shaobo; Guishen, Liang; Pan, Tonglin; He, JunZhang; Guo, Zhanchen

    2011-12-15

    Thermodynamic and kinetics studies for adsorption of Pt ions complexes from the chloride solutions obtained by leaching chlorinated spent automotive catalysts on anionic exchange resin Diaion WA21J were carried out. It was found that only Si, Pt, Rh and Pd from the solution were selectively adsorbed on the resin Diaion WA21J more strongly. The adsorption equilibrium time for Pt ions was about 20 h. The isothermal adsorption of Pt ions was found to fit Langmuir, Freundlich and DKR models. The maximum monolayer adsorption capacities Q(max) and X(m) of Pt ions on the resin based on Langmuir and DKR model were 4.85, 5.36 and 5.69 mg/g as well as 5.01, 5.63 and 5.98 mg/g for temperatures 18°C, 28°C and 40°C, respectively. The apparent adsorption energy E(ad) based on DKR model were -11.79, -11.04 and -11.04 kJ/mol for the temperatures 18°C, 28°C and 40°C, respectively. Ion exchange was the mechanism involved in the adsorption process. The adsorption of Pt ions on the resin underwent pseudo-first-order kinetic process, and the apparent adsorption activation energy E(a,1) was 12.6 kJ/mol. The intraparticle diffusion of Pt ions was a main rate-controlling step in most of time of adsorption process. Copyright © 2011 Elsevier Inc. All rights reserved.

  4. THC/CBD oromucosal spray in patients with multiple sclerosis overactive bladder: a pilot prospective study.

    PubMed

    Maniscalco, Giorgia Teresa; Aponte, R; Bruzzese, D; Guarcello, G; Manzo, V; Napolitano, M; Moreggia, O; Chiariello, F; Florio, C

    2018-01-01

    Lower urinary tract dysfunctions (LUTDs) are commonly reported in multiple sclerosis (MS) patients and are mainly related to neurogenic overactive bladder (OAB). The aim of this observational study was to assess the effect of a tetrahydrocannabinol-cannabidiol (THC/CBD) oromucosal spray on resistant OAB by means of clinical and instrumental tools. Twenty-one MS patients were screened, and 15 cases have been evaluated. They underwent a specific clinical assessment (overactive bladder symptom score, OABSS) and a urodynamic assessment evaluating the maximal cystometric capacity (CCmax), bladder compliance (Qmax), maximum detrusor pressure (Pdet max), detrusor pressure at the first desire (Pdet first), bladder volume at the first desire (BVFD), leakage volume (LV), and post-void residual volume (PVR), before and after 4 weeks of THC/CBD administration. A complete neurological evaluation, including the assessment of their spasticity using the Modified Ashworth Scale (MAS) and the spasticity 0-10 numerical rating scale (NRS), was performed at the same times. Mobility was evaluated through the 25-ft walking-time test (T25-WT). The THC/CBD treatment successfully reduced the OAB symptoms (p = 0.001). Regarding the urodynamic findings after the end of treatment, PVR was significantly reduced (p = 0.016). Regarding the urodynamic findings after the end of treatment, PVR was significantly reduced (p = 0.016), while BVFD and CCmax were increased although the difference was not statistically significant. THC/CBD oromucosal spray has shown to be effective in improving overactive bladder symptoms in MS patients demonstrating a favorable impact on detrusor overactivity.

  5. Comparison of Tissue Heat Balance- and Thermal Dissipation-Derived Sap Flow Measurements in Ring-Porous Oaks and a Pine

    PubMed Central

    Renninger, Heidi J.; Schäfer, Karina V. R.

    2012-01-01

    Sap flow measurements have become integral in many physiological and ecological investigations. A number of methods are used to estimate sap flow rates in trees, but probably the most popular is the thermal dissipation (TD) method because of its affordability, relatively low power consumption, and ease of use. However, there have been questions about the use of this method in ring-porous species and whether individual species and site calibrations are needed. We made concurrent measurements of sap flow rates using TD sensors and the tissue heat balance (THB) method in two oak species (Quercus prinus Willd. and Quercus velutina Lam.) and one pine (Pinus echinata Mill.). We also made concurrent measurements of sap flow rates using both 1 and 2-cm long TD sensors in both oak species. We found that both the TD and THB systems tended to match well in the pine individual, but sap flow rates were underestimated by 2-cm long TD sensors in five individuals of the two ring-porous oak species. Underestimations of 20–35% occurred in Q. prinus even when a “Clearwater” correction was applied to account for the shallowness of the sapwood depth relative to the sensor length and flow rates were underestimated by up to 50% in Q. velutina. Two centimeter long TD sensors also underestimated flow rates compared with 1-cm long sensors in Q. prinus, but only at large flow rates. When 2-cm long sensor data in Q. prinus were scaled using the regression with 1-cm long data, daily flow rates matched well with the rates measured by the THB system. Daily plot level transpiration estimated using TD sap flow rates and scaled 1 cm sensor data averaged about 15% lower than those estimated by the THB method. Therefore, these results suggest that 1-cm long sensors are appropriate in species with shallow sapwood, however more corrections may be necessary in ring-porous species. PMID:22661978

  6. The dependency of expiratory airway collapse on pump system and flow rate in liquid ventilated rabbits.

    PubMed

    Meinhardt, J P; Ashton, B A; Annich, G M; Quintel, M; Hirschl, R B

    2003-05-30

    To evaluate the influence of pump system and flow pattern on expiratory airway collapse (EAC) in total perfluorocarbon ventilation. - Prospective, controlled, randomized animal trial for determination of (1) post-mortem changes by repeated expiration procedures (EP) with a constant flow piston pump (PP) before and after sacrifice (n = 8 rabbits), (2) differences between pump systems by subjecting animals to both PP and roller pump (RP) circuits for expiration (n = 16 rabbits). EP were performed using a servo-controlled shut-off at airway pressures < 25 cm H subset 2O randomly with either pump at different flows. - Expired volumes before and after sacrifice were not significantly different. PP and RP revealed identical mean flows, while significantly more liquid was drained using PP (p<0.05). Increasing differences towards higher flow rates indicated profound flow pulsatility in RP. - (1) post-mortem changes in expired volumes are not significant, (2) EAC is related to flow rate and pump system; (3) relationship between expiratory flow rate and drainable liquid volume is linear inverse; (4) PP provides higher drainage than RP. - Expiratory airway collapse is related to flow rate and pump system, post mortem changes in expirable volumes are not significant. Relationship between expiratory flow rate and drainable liquid volume is linear inverse, piston pump expiration provides higher drainage volumes than roller pump expiration.

  7. Extraction of long-chain fatty acids in isolated rat heart during acute low-flow ischemia.

    PubMed

    Richter, W S; Fischer, S; Ernst, N; Munz, D L

    2001-07-01

    Although beta-oxidation of fatty acids is suppressed rapidly during ischemia, the behavior of fatty acid extraction at different flow rates is incompletely understood. This study assessed the relationship between flow and extraction of (123)I-iodophenylpentadecanoic acid (IPPA) in the isolated heart model, especially at low flow. Isolated hearts from male Wistar rats (n = 15) were subjected to retrograde perfusion with constant flow (Krebs Henseleit solution containing 10 mmol/L glucose). A latex balloon in the left ventricle allowed isovolumetric contractions and ventricular pressure measurements. The extraction of (123)I-IPPA was assessed with the indicator dilution technique and (99m)Tc-albumin as the intravascular reference. The flow was either increased from the control flow (8 mL/min) until 300% or reduced until 10%. (123)I-IPPA extraction was measured three times before and 10 min after flow alteration. The tracer uptake was estimated from the product of net extraction and flow. The mean (123)I-IPPA extraction at the control flow (third measurement) was 51.6% +/- 2.8%. Between flow rates of approximately 25% and 300%, (123)I-IPPA extraction increased exponentially at decreasing flow rates. At flow rates < or =25% of the control flow, (123)I-IPPA extraction was exponentially higher than predicted. (123)I-IPPA uptake and flow changed largely in parallel. During low flow, the rate-pressure product showed the expected decline (perfusion-contraction matching). The extraction of (123)I-IPPA is preserved and slightly increased (relative to flow) during acute low-flow ischemia.

  8. Measuring Your Peak Flow Rate

    MedlinePlus

    ... Living with Asthma > Managing Asthma Measuring Your Peak Flow Rate Download Instructions A peak flow meter is ... to use. Who Benefits from Using a Peak Flow Meter? Many healthcare providers believe that people who ...

  9. Experiments and 3D simulations of flow structures in junctions and their influence on location of flowmeters.

    PubMed

    Mignot, E; Bonakdari, H; Knothe, P; Lipeme Kouyi, G; Bessette, A; Rivière, N; Bertrand-Krajewski, J-L

    2012-01-01

    Open-channel junctions are common occurrences in sewer networks and flow rate measurement often occurs near these singularities. Local flow structures are 3D, impact on the representativeness of the local flow measurements and thus lead to deviations in the flow rate estimation. The present study aims (i) to measure and simulate the flow pattern in a junction flow, (ii) to analyse the impact of the junction on the velocity distribution according to the distance from the junction and thus (iii) to evaluate the typical error derived from the computation of the flow rate close to the junction.

  10. Gaseous oxygen uptake in porous media at different moisture contents and airflow velocities.

    PubMed

    Sharma, Prabhakar; Poulsen, Tjalfe G; Kalluri, Prasad N V

    2009-06-01

    The presence and distribution of water in the pore space is a critical factor for flow and transport of gases through unsaturated porous media. The water content also affects the biological activity necessary for treatment of polluted gas streams in biofilters. In this research, microbial activity and quantity of inactive volume in a porous medium as a function of moisture content and gas flow rate were investigated. Yard waste compost was used as a test medium, and oxygen uptake rate measurements were used to quantify microbial activity and effective active compost volume using batch and column flow-through systems. Compost water contents were varied from air-dry to field capacity and gas flows ranged from 0.2 to 2 L x min(-1). The results showed that overall microbial activity and the relative fraction of active compost medium volume increased with airflow velocity for all levels of water content up to a certain flow rate above which the oxygen uptake rate assumed a constant value independent of gas flow. The actual value of the maximum oxygen uptake rate was controlled by the water content. The oxygen uptake rate also increased with increasing water content and reached a maximum between 42 and 48% volumetric water content, above which it decreased, again likely because of formation of inactive zones in the compost medium. Overall, maximum possible oxygen uptake rate as a function of gas flow rate across all water contents and gas flows could be approximated by a linear expression. The relative fraction of active volume also increased with gas flow rate and reached approximately 80% for the highest gas flows used.

  11. Performance of different PEEP valves and helmet outlets at increasing gas flow rates: a bench top study.

    PubMed

    Isgrò, S; Zanella, A; Giani, M; Abd El Aziz El Sayed Deab, S; Pesenti, A; Patroniti, N

    2012-10-01

    Aim of the paper was to assess the performance of different expiratory valves and the resistance of helmet outlet ports at increasing gas flow rates. A gas flow-meter was connected to 10 different expiratory peep valves: 1 water-seal valve, 4 precalibrated fixed PEEP valves and 5 adjustable PEEP valves. Three new valves of each brand, set at different pressure levels (5-7.5-10-12.5-15 cmH(2)O, if available), were tested at increasing gas flow rates (from 30 to 150 L/min). We measured the pressure generated just before the valves. Three different helmets sealed on a mock head were connected at the inlet port with a gas flow-meter while the outlet was left clear. We measured the pressure generated inside the helmet (due to the flow-resistance of the outlet port) at increasing gas flow rates. Adjustable valves showed a variable degree flow-dependency (increasing difference between the measured and the expected pressure at increasing flow rates), while pre-calibrated valves revealed a flow-independent behavior. Water seal valve showed low degree flow-dependency. The pressures generated by the outlet port of the tested helmets ranged from 0.02 to 2.29 cmH(2)O at the highest gas flow rate. Adjustable PEEP valves are not suggested for continuous-flow CPAP systems as their flow-dependency can lead to pressures higher than expected. Precalibrated and water seal valves exhibit the best performance. Different helmet outlet ports do not significantly affect the pressure generated during helmet CPAP. In order to avoid iatrogenic complications gas flow and pressure delivered during helmet CPAP must always be monitored.

  12. Microfluidic rheology of active particle suspensions: Kinetic theory

    NASA Astrophysics Data System (ADS)

    Alonso-Matilla, Roberto; Ezhilan, Barath; Saintillan, David

    2016-11-01

    We analyze the effective rheology of a dilute suspension of self-propelled slender particles between two infinite parallel plates in a pressure-driven flow. We use a continuum kinetic model to study the dynamics and transport of particles, where hydrodynamic interactions induced by the swimmers are taken into account. Using finite volume simulations we study how the activity of the swimmer and the external flow modify the rheological properties of the system. Results indicate that at low flow rates, activity decreases the value of the viscosity for pushers and increases its value for pullers. Both effects become weaker with increasing the flow strength due to the alignment of the particles with the flow. In the case of puller particles, shear thinning is observed over the entire range of flow rates. Pusher particles exhibit shear thickening at intermediate flow rates, where passive stresses start dominating over active stresses, reaching a viscosity greater than that of the Newtonian fluid. Finally shear thinning is observed at high flow rates. Both pushers and pullers exhibit a Newtonian plateau at very high flow rates. We demonstrate a good agreement between numerical results and experiments.

  13. 40 CFR 98.154 - Monitoring and QA/QC requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the concentrations of the process samples. (b) The mass flow of the product stream containing the HFC... concentration and volumetric flow rate determined by measurement of volumetric flow rate using EPA Method 2, 2A... volumetric flow rate at the inlet or by a metering device for HFC-23 sent to the device. Determine a new...

  14. Characteristics of an aerosol photometer while automatically controlling chamber dilution-air flow rate.

    PubMed

    O'Shaughnessy, P T; Hemenway, D R

    2000-10-01

    Trials were conducted to determine those factors that affect the accuracy of a direct-reading aerosol photometer when automatically controlling airflow rate within an exposure chamber to regulate airborne dust concentrations. Photometer response was affected by a shift in the aerosol size distribution caused by changes in chamber flow rate. In addition to a dilution effect, flow rate also determined the relative amount of aerosol lost to sedimentation within the chamber. Additional calculations were added to a computer control algorithm to compensate for these effects when attempting to automatically regulate flow based on a proportional-integral-derivative (PID) feedback control algorithm. A comparison between PID-controlled trials and those performed with a constant generator output rate and dilution-air flow rate demonstrated that there was no significant decrease in photometer accuracy despite the many changes in flow rate produced when using PID control. Likewise, the PID-controlled trials produced chamber aerosol concentrations within 1% of a desired level.

  15. Method and system for gas flow mitigation of molecular contamination of optics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Delgado, Gildardo; Johnson, Terry; Arienti, Marco

    A computer-implemented method for determining an optimized purge gas flow in a semi-conductor inspection metrology or lithography apparatus, comprising receiving a permissible contaminant mole fraction, a contaminant outgassing flow rate associated with a contaminant, a contaminant mass diffusivity, an outgassing surface length, a pressure, a temperature, a channel height, and a molecular weight of a purge gas, calculating a flow factor based on the permissible contaminant mole fraction, the contaminant outgassing flow rate, the channel height, and the outgassing surface length, comparing the flow factor to a predefined maximum flow factor value, calculating a minimum purge gas velocity and amore » purge gas mass flow rate from the flow factor, the contaminant mass diffusivity, the pressure, the temperature, and the molecular weight of the purge gas, and introducing the purge gas into the semi-conductor inspection metrology or lithography apparatus with the minimum purge gas velocity and the purge gas flow rate.« less

  16. Simulation of blood flow in a small-diameter vascular graft model with a swirl (spiral) flow guider.

    PubMed

    Zhang, ZhiGuo; Fan, YuBo; Deng, XiaoYan; Wang, GuiXue; Zhang, He; Guidoin, Robert

    2008-10-01

    Small-diameter vascular grafts are in large demand for coronary and peripheral bypass procedures, but present products still fail in long-term clinical application. In the present communication, a new type of small-diameter graft with a swirl flow guider was proposed to improve graft patency rate. Flow pattern in the graft was simulated numerically and compared with that in a conventional graft. The numerical results revealed that the swirl flow guider could indeed make the blood flow rotate in the new graft. The swirling flow distal to the flow guider significantly altered the flow pattern in the new graft and the velocity profiles were re-distributed. Due to the swirling flow, the blood velocity near the vessel wall and wall shear rate were greatly enhanced. We believe that the increased blood velocity near the wall and the wall shear rate can impede the occurrence of acute thrombus formation and intimal hyperplasia, hence can improve the graft patency rate for long-term clinical use.

  17. Effect of stress, anxiety and depression on unstimulated salivary flow rate and xerostomia.

    PubMed

    Gholami, Neda; Hosseini Sabzvari, Behrous; Razzaghi, Alireza; Salah, Shilan

    2017-01-01

    Background. Unstimulated salivary flow rate can be influenced by different factors. This study was undertaken to evaluate the effect of stress, anxiety and depression on unstimulated salivary flow rate in adults. Methods. A total of 247 adult subjects, randomly selected from patients referring to Zanjan Dental School, were included in this investigation. The study procedures consisted of collecting salivary samples (in 5 minutes), completing a form for feeling of xerostomia and completing Depression Anxiety Stress Scale (DASS) Questionnaire to assess the severity of stress, anxiety and depression. Based on the results, the patients were categorized in four groups: Low salivary flow rate plus xerostomia (group 1, n=60), normal salivary flow rate plus xerostomia (group 2, n=59), low salivary flow rate without xerostomia (group 3, n=60) and normal salivary flow rate without xerostomia (control group, n=68). Results. The frequencies of subjects with severe and major depression in groups 1, 2 and 3 were 31.4%, 11.7% and 8.5%, respectively, with 4.4% in the control group. The frequencies of subjects with severe stress in groups 1, 2 and 3 were 21.7%, 3.3% and 11.9%, respectively, with 1.5% in the control group. The frequencies of patients with severe anxiety in groups 1, 2 and 3 were 50%, 30% and 61.1%, respectively, with 4.4% in the control group. Stress, anxiety and depression exhibited a statistically significant relationship with unstimulated salivary flow rate and xerostomia (P<0.05). Conclusion. Stress, anxiety and depression can influence unstimulated salivary flow rate and lead to xerostomia.

  18. Natural gas flow through critical nozzles

    NASA Technical Reports Server (NTRS)

    Johnson, R. C.

    1969-01-01

    Empirical method for calculating both the mass flow rate and upstream volume flow rate through critical flow nozzles is determined. Method requires knowledge of the composition of natural gas, and of the upstream pressure and temperature.

  19. Phosphorus doping of Si and Si1 - xGex grown by ultrahigh vacuum chemical vapor deposition using Si2H6 and GeH4

    NASA Astrophysics Data System (ADS)

    Chen, L. P.; Huang, G. W.; Chang, C. Y.

    1996-03-01

    100 ppm PH3 diluted in hydrogen is used as the n-type dopant gas in Si and Si1-xGex epilayers grown by ultrahigh vacuum chemical vapor deposition (UHVCVD) using Si2H6 and GeH4. The phosphorus concentration in Si increases linearly at a small PH3 flow rate and becomes nearly saturated at higher flow rates, while the phosphorus concentration in Si1-xGex only shows a nearly linear behavior with PH3 flow rate. The growth rates of Si and Si1-xGex epilayers decrease seriously (˜50%) and slightly (˜10%) with the increase of PH3 flow rate, respectively. These results can be explained by a model based on the enhancement of hydrogen desorption rate at smaller PH3 flow rates and different levels of the effects of phosphorus blocking of surface-activated sites between Si and Si1-xGex epilayers at higher PH3 flow rates.

  20. Off-design flow measurements in a centrifugal compressor vaneless diffuser

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pinarbasi, A.; Johnson, M.W.

    1995-10-01

    Detailed measurements have been taken of the three-dimensional velocity field within the vaneless diffuser of a backswept low speed centrifugal compressor using hot-wire anemometry. A 16% below and an 11% above design flow rate were used in the present study. Results at both flow rates show how the blade wake mixes out more rapidly than the passage wake. Strong secondary flows inherited from the impeller at the higher flow rate delay the mixing out of the circumferential velocity variations, but at both flow rates these circumferential variations are negligible at the last measurement station. The measured tangential/radial flow angle ismore » used to recommend optimum values for the vaneless space and vane angle for design of a vaned diffuser.« less

  1. Self-regulating flow control device

    DOEpatents

    Humphreys, Duane A.

    1984-01-01

    A variable, self-regulating valve having a hydraulic loss coefficient proportional to a positive exponential power of the flow rate. The device includes two objects in a flow channel and structure which assures that the distance between the two objects is an increasing function of the flow rate. The range of spacing between the objects is such that the hydraulic resistance of the valve is an increasing function of the distance between the two objects so that the desired hydraulic loss coefficient as a function of flow rate is obtained without variation in the flow area.

  2. Control of Advanced Reactor-Coupled Heat Exchanger System: Incorporation of Reactor Dynamics in System Response to Load Disturbances

    DOE PAGES

    Skavdahl, Isaac; Utgikar, Vivek; Christensen, Richard; ...

    2016-05-24

    We present an alternative control schemes for an Advanced High Temperature Reactor system consisting of a reactor, an intermediate heat exchanger, and a secondary heat exchanger (SHX) in this paper. One scheme is designed to control the cold outlet temperature of the SHX (T co) and the hot outlet temperature of the intermediate heat exchanger (T ho2) by manipulating the hot-side flow rates of the heat exchangers (F h/F h2) responding to the flow rate and temperature disturbances. The flow rate disturbances typically require a larger manipulation of the flow rates than temperature disturbances. An alternate strategy examines the controlmore » of the cold outlet temperature of the SHX (T co) only, since this temperature provides the driving force for energy production in the power conversion unit or the process application. The control can be achieved by three options: (1) flow rate manipulation; (2) reactor power manipulation; or (3) a combination of the two. The first option has a quicker response but requires a large flow rate change. The second option is the slowest but does not involve any change in the flow rates of streams. The final option appears preferable as it has an intermediate response time and requires only a minimal flow rate change.« less

  3. Does water content or flow rate control colloid transport in unsaturated porous media?

    PubMed

    Knappenberger, Thorsten; Flury, Markus; Mattson, Earl D; Harsh, James B

    2014-04-01

    Mobile colloids can play an important role in contaminant transport in soils: many contaminants exist in colloidal form, and colloids can facilitate transport of otherwise immobile contaminants. In unsaturated soils, colloid transport is, among other factors, affected by water content and flow rate. Our objective was to determine whether water content or flow rate is more important for colloid transport. We passed negatively charged polystyrene colloids (220 nm diameter) through unsaturated sand-filled columns under steady-state flow at different water contents (effective water saturations Se ranging from 0.1 to 1.0, with Se = (θ - θr)/(θs - θr)) and flow rates (pore water velocities v of 5 and 10 cm/min). Water content was the dominant factor in our experiments. Colloid transport decreased with decreasing water content, and below a critical water content (Se < 0.1), colloid transport was inhibited, and colloids were strained in water films. Pendular ring and water film thickness calculations indicated that colloids can move only when pendular rings are interconnected. The flow rate affected retention of colloids in the secondary energy minimum, with less colloids being trapped when the flow rate increased. These results confirm the importance of both water content and flow rate for colloid transport in unsaturated porous media and highlight the dominant role of water content.

  4. Mass flow rate measurements in gas-liquid flows by means of a venturi or orifice plate coupled to a void fraction sensor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oliveira, Jorge Luiz Goes; Passos, Julio Cesar; Verschaeren, Ruud

    Two-phase flow measurements were carried out using a resistive void fraction meter coupled to a venturi or orifice plate. The measurement system used to estimate the liquid and gas mass flow rates was evaluated using an air-water experimental facility. Experiments included upward vertical and horizontal flow, annular, bubbly, churn and slug patterns, void fraction ranging from 2% to 85%, water flow rate up to 4000 kg/h, air flow rate up to 50 kg/h, and quality up to almost 10%. The fractional root mean square (RMS) deviation of the two-phase mass flow rate in upward vertical flow through a venturi platemore » is 6.8% using the correlation of Chisholm (D. Chisholm, Pressure gradients during the flow of incompressible two-phase mixtures through pipes, venturis and orifice plates, British Chemical Engineering 12 (9) (1967) 454-457). For the orifice plate, the RMS deviation of the vertical flow is 5.5% using the correlation of Zhang et al. (H.J. Zhang, W.T. Yue, Z.Y. Huang, Investigation of oil-air two-phase mass flow rate measurement using venturi and void fraction sensor, Journal of Zhejiang University Science 6A (6) (2005) 601-606). The results show that the flow direction has no significant influence on the meters in relation to the pressure drop in the experimental operation range. Quality and slip ratio analyses were also performed. The results show a mean slip ratio lower than 1.1, when bubbly and slug flow patterns are encountered for mean void fractions lower than 70%. (author)« less

  5. Determining Coolant Flow Rate Distribution In The Fuel-Modified TRIGA Plate Reactor

    NASA Astrophysics Data System (ADS)

    Puji Hastuti, Endiah; Widodo, Surip; Darwis Isnaini, M.; Geni Rina, S.; Syaiful, B.

    2018-02-01

    TRIGA 2000 reactor in Bandung is planned to have the fuel element replaced, from cylindrical uranium and zirconium-hydride (U-ZrH) alloy to U3Si2-Al plate type of low enriched uranium of 19.75% with uranium density of 2.96 gU/cm3, while the reactor power is maintained at 2 MW. This change is planned to anticipate the discontinuity of TRIGA fuel element production. The selection of this plate-type fuel element is supported by the fact that such fuel type has been produced in Indonesia and used in MPR-30 safely since 2000. The core configuration of plate-type-fuelled TRIGA reactor requires coolant flow rate through each fuel element channel in order to meet its safety function. This paper is aimed to describe the results of coolant flow rate distribution in the TRIGA core that meets the safety function at normal operation condition, physical test, shutdown, and at initial event of loss of coolant flow due power supply interruption. The design analysis to determine coolant flow rate in this paper employs CAUDVAP and COOLODN computation code. The designed coolant flow rate that meets the safety criteria of departure from nucleate boiling ratio (DNBR), onset of flow instability ratio (OFIR), and ΔΤ onset of nucleate boiling (ONB), indicates that the minimum flow rate required to cool the plate-type fuelled TRIGA core at 2 MW is 80 kg/s. Therefore, it can be concluded that the operating limitation condition (OLC) for the minimum flow rate is 80 kg/s; the 72 kg/s is to cool the active core; while the minimum flow rate for coolant flow rate drop is limited to 68 kg/s with the coolant inlet temperature 35°C. This thermohydraulic design also provides cooling for 4 positions irradiation position (IP) utilization and 1 central irradiation position (CIP) with end fitting inner diameter (ID) of 10 mm and 20 mm, respectively.

  6. Stability limits of unsteady open capillary channel flow

    NASA Astrophysics Data System (ADS)

    Grah, Aleksander; Haake, Dennis; Rosendahl, Uwe; Klatte, J.?Rg; Dreyer, Michael E.

    This paper is concerned with steady and unsteady flow rate limitations in open capillary channels under low-gravity conditions. Capillary channels are widely used in Space technology for liquid transportation and positioning, e.g. in fuel tanks and life support systems. The channel observed in this work consists of two parallel plates bounded by free liquid surfaces along the open sides. The capillary forces of the free surfaces prevent leaking of the liquid and gas ingestion into the flow.In the case of steady stable flow the capillary pressure balances the differential pressure between the liquid and the surrounding constant-pressure gas phase. Increasing the flow rate in small steps causes a decrease of the liquid pressure. A maximum steady flow rate is achieved when the flow rate exceeds a certain limit leading to a collapse of the free surfaces due to the choking effect. In the case of unsteady flow additional dynamic effects take place due to flow rate transition and liquid acceleration. The maximum flow rate is smaller than in the case of steady flow. On the other hand, the choking effect does not necessarily cause surface collapse and stable temporarily choked flow is possible under certain circumstances.To determine the limiting volumetric flow rate and stable flow dynamic properties, a new stability theory for both steady and unsteady flow is introduced. Subcritical and supercritical (choked) flow regimes are defined. Stability criteria are formulated for each flow type. The steady (subcritical) criterion corresponds to the speed index defined by the limiting longitudinal small-amplitude wave speed, similar to the Mach number. The unsteady (supercritical) criterion for choked flow is defined by a new characteristic number, the dynamic index. It is based on pressure balances and reaches unity at the stability limit.The unsteady model based on the Bernoulli equation and the mass balance equation is solved numerically for perfectly wetting incompressible liquids. The unsteady model and the stability theory are verified by comparison to results of a sounding rocket experiment (TEXUS 41) on capillary channel flows launched in December 2005 from ESRANGE in north Sweden. For a clear overview of subcritical, supercritical, and unstable flow, parametric studies and stability diagrams are shown and compared to experimental observations.

  7. Computer code for predicting coolant flow and heat transfer in turbomachinery

    NASA Technical Reports Server (NTRS)

    Meitner, Peter L.

    1990-01-01

    A computer code was developed to analyze any turbomachinery coolant flow path geometry that consist of a single flow passage with a unique inlet and exit. Flow can be bled off for tip-cap impingement cooling, and a flow bypass can be specified in which coolant flow is taken off at one point in the flow channel and reintroduced at a point farther downstream in the same channel. The user may either choose the coolant flow rate or let the program determine the flow rate from specified inlet and exit conditions. The computer code integrates the 1-D momentum and energy equations along a defined flow path and calculates the coolant's flow rate, temperature, pressure, and velocity and the heat transfer coefficients along the passage. The equations account for area change, mass addition or subtraction, pumping, friction, and heat transfer.

  8. Internal Flow of Contra-Rotating Small Hydroturbine at Off- Design Flow Rates

    NASA Astrophysics Data System (ADS)

    SHIGEMITSU, Toru; TAKESHIMA, Yasutoshi; OGAWA, Yuya; FUKUTOMI, Junichiro

    2016-11-01

    Small hydropower generation is one of important alternative energy, and enormous potential lie in the small hydropower. However, efficiency of small hydroturbines is lower than that of large one. Then, there are demands for small hydroturbines to keep high performance in wide flow rate range. Therefore, we adopted contra-rotating rotors, which can be expected to achieve high performance. In this research, performance of the contra-rotating small hydroturbine with 60mm casing diameter was investigated by an experiment and numerical analysis. Efficiency of the contra-rotating small hydroturbine was high in pico-hydroturbine and high efficiency could be kept in wide flow rate range, however the performance of a rear rotor decreased significantly in partial flow rates. Then, internal flow condition, which was difficult to measure experimentally, was investigated by the numerical flow analysis. Then, a relation between the performance and internal flow condition was considered by the numerical analysis result.

  9. Quaternary Basalts in Grand Canyon: Correlation of Flows Using Lidar, 40Ar/39Ar Dating, Geochemical Correlation, Neotectonic Studies, and History of Lava Dams

    NASA Astrophysics Data System (ADS)

    Crow, R. S.; Karlstrom, K. E.; McIntosh, W. C.; Dunbar, N. W.; Peters, L.; Raucci, J.; Umhoefer, P. J.

    2005-12-01

    In western Grand Canyon, basalts flowed into the already existing canyon from at least 719 ka to present. These basalts provide a key for deciphering Quaternary rates of incision, neotectonic slip rates on the Toroweap and Hurricane faults, and the history of lava dams. Stratigraphy and/or inset relationships between basalt flows is exceedingly complex because of the multiple eruptions, extreme topography, long transport distance, and incomplete preservation. Correlation of flows using 40Ar/39Ar dating, LIDAR data, orthophotography, and geochemical analysis, as well as structural and geomorphic studies, lead to a working hypothesis for four major episodes of basaltic eruptive activity. From 719 to 484 Ma major volcanoes erupted near the Toroweap fault zone. The extent of the remnants and presence of 527 ka dikes indicates that cones where built within Grand Canyon during this phase. These flows had the longest outflow (719 ka flow at mile 246). At 349 to 296 ka flows seem to have entered the canyon at Whitmore Wash, north rim. The two remaining episodes, dated at 199-193 ka and 109-97 ka are interpreted to have cascaded into the canyon at and upstream from Whitmore Wash. LIDAR/orthophotography interpretation of the tops and bottoms of the flows and geochemical analysis of phenocrysts aid in correlation of undated remnants and reconstructing the shape of volcanic edifices. Flows dated from 720-450 ka include Prospect, Black Ledge, D-Dam, and Toroweap flows, thus Black Ledge flows are considerably older than previously thought. The 350 to 300 flows include Whitmore, Layered Diabase, Massive Diabase, and 177-mile flows. All the dated 200 and 100 ka flows have been called Grey Ledge flows, suggesting that the Grey Ledge represents two distinct events. Basalt data indicate an interaction of canyon incision and Quaternary fault slip. Bedrock incision rates are calculated using dated flows that overly bedrock straths. Rates vary across active faults indicating fault dampening of apparent river incision rates. Incision rates for eastern Grand Canyon are 127 m/my over 387 ka. Similar rates just east of the Toroweap faults (136 m/my over 349 ka and 153 m/my over 484 ka) suggest that a fairly uniform regional rate of ~ 140 m/my can be considered the average rate for Grand Canyon incision east of the Toroweap fault. This is subequal to the sum of apparent incision rate just below the Toroweap fault (56 m/my over 484 ka) plus fault slip rate (90 m/my over 550 ka). Similarly, apparent incision rates below the Hurricane fault (66 m/my over 527 ka and 76 m/my over 604 ka, near Granite Park) plus fault slip rate (~80±20 m/my over 185 ka) is subequal to the far field incision rate. Accumulating data suggests that apparent incision rates are lowest adjacent to faults in the hanging wall and highest adjacent to faults in the footwall, with rates varying systematically across fault blocks. This suggests that faulting is taking place by domino rotation of blocks bounded by normal faults with mild listric character. These new empirical data help constrain physical models for Quaternary fault slip across the active Colorado Plateau- Basin and Range bounding structures.

  10. The Urolift System for the Treatment of Lower Urinary Tract Symptoms Secondary to Benign Prostatic Hyperplasia: A NICE Medical Technology Guidance.

    PubMed

    Ray, Alistair; Morgan, Helen; Wilkes, Antony; Carter, Kimberley; Carolan-Rees, Grace

    2016-10-01

    As part of its Medical Technologies Evaluation Programme (MTEP), the National Institute for Health and Care Excellence (NICE) invited Neotract (manufacturer) to submit clinical and economic evidence for their prostatic urethral lift device, Urolift, for the relief of lower urinary tract symptoms secondary to benign prostatic hyperplasia (LUTS BPH). The Urolift System uses implants to retract the prostatic lobe away from the urethral lumen. The clinical evidence used in the manufacturer's submission shows that Urolift is effective for the treatment of BPH. Urolift delivers a weighted mean International Prostate Symptom Score (IPSS) improvement of between 9.22 and 11.82 points. These Urolift improvements are greater than a published 'marked improvement' in IPSS score of 8.80. Comparison with randomised controlled trials (RCTs) of TURP (Transurethral Resection of Prostate) and HoLEP (Holmium Laser Enucleation of Prostate) show that Urolift does not yield better clinical outcomes from baseline compared to TURP and HoLEP in terms of IPSS, QoL (Quality of Life) and Qmax (maximum urinary flow). However, Urolift appears to have the advantage in terms of minimal and mild complications, and this may be of interest to patients and urologists. The economic case for Urolift was made using a very detailed and thorough de novo cost model. The base case posed by the manufacturer placed Urolift at almost cost-neutral (£3 cost incurring, based on 2014 prices) compared to TURP, and £418 cost incurring compared to HoLEP. In an additional scenario comparing day-case Urolift with in-patient TURP, the estimated per-patient savings with Urolift were £286 compared with monopolar TURP (mTURP) and £159 compared with bipolar TURP (BiTURP). NICE guidance MTG26 recommends that the case for adoption of Urolift was supported by the evidence, when implemented in a day-case setting.

  11. What is the relationship between free flow and pressure flow studies in women?

    PubMed

    Duckett, Jonathan; Cheema, Katherine; Patil, Avanti; Basu, Maya; Beale, Sian; Wise, Brian

    2013-03-01

    The relationship between free flow (FFS) and pressure flow (PFS) voiding studies remains uncertain and the effect of a urethral catheter on flow rates has not been determined. The relationship between residuals obtained at FF and PFS has yet to be established. This was a prospective cohort study based on 474 consecutive women undergoing cystometry using different sized urethral catheters at different centres. FFS and PFS data were compared for different conditions and the relationship of residuals analysed for FFS and PFS. The null hypothesis was that urethral catheters do not produce an alteration in maximum flow rates for PFS and FF studies. Urethral catheterisation results in lower flow rates (p < 0.01) and this finding is confirmed when flows are corrected for voided volume (p < 0.01). FFS and PFS maximum flow rates are lower in women with DO than USI (p < 0.01). A 6-F urethral catheter does not have a significantly greater effect than a 4.5-F urethral catheter. A mathematical model can be applied to transform FFS to PFS flow rates and vice versa. There was no significant difference between the mean residuals of the two groups (FFS vs PFS-two-tailed t = 0.54, p = 0.59). Positive residuals in FFS showed a good association with positive residuals in the PFS (r = 0.53, p < 0.01) Urethral catheterisation results in lower maximum flow rates. The relationship can be compared mathematically. The null hypothesis can be rejected.

  12. Can hydraulic-modelled rating curves reduce uncertainty in high flow data?

    NASA Astrophysics Data System (ADS)

    Westerberg, Ida; Lam, Norris; Lyon, Steve W.

    2017-04-01

    Flood risk assessments rely on accurate discharge data records. Establishing a reliable rating curve for calculating discharge from stage at a gauging station normally takes years of data collection efforts. Estimation of high flows is particularly difficult as high flows occur rarely and are often practically difficult to gauge. Hydraulically-modelled rating curves can be derived based on as few as two concurrent stage-discharge and water-surface slope measurements at different flow conditions. This means that a reliable rating curve can, potentially, be derived much faster than a traditional rating curve based on numerous stage-discharge gaugings. In this study we compared the uncertainty in discharge data that resulted from these two rating curve modelling approaches. We applied both methods to a Swedish catchment, accounting for uncertainties in the stage-discharge gauging and water-surface slope data for the hydraulic model and in the stage-discharge gauging data and rating-curve parameters for the traditional method. We focused our analyses on high-flow uncertainty and the factors that could reduce this uncertainty. In particular, we investigated which data uncertainties were most important, and at what flow conditions the gaugings should preferably be taken. First results show that the hydraulically-modelled rating curves were more sensitive to uncertainties in the calibration measurements of discharge than water surface slope. The uncertainty of the hydraulically-modelled rating curves were lowest within the range of the three calibration stage-discharge gaugings (i.e. between median and two-times median flow) whereas uncertainties were higher outside of this range. For instance, at the highest observed stage of the 24-year stage record, the 90% uncertainty band was -15% to +40% of the official rating curve. Additional gaugings at high flows (i.e. four to five times median flow) would likely substantially reduce those uncertainties. These first results show the potential of the hydraulically-modelled curves, particularly where the calibration gaugings are of high quality and cover a wide range of flow conditions.

  13. 40 CFR 89.415 - Fuel flow measurement specifications.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Fuel flow measurement specifications... Emission Test Procedures § 89.415 Fuel flow measurement specifications. The fuel flow rate measurement instrument must have a minimum accuracy of 2 percent of the engine maximum fuel flow rate. The controlling...

  14. Steam distillation extraction of ginger essential oil: Study of the effect of steam flow rate and time process

    NASA Astrophysics Data System (ADS)

    Fitriady, Muhammad Arifuddin; Sulaswatty, Anny; Agustian, Egi; Salahuddin, Aditama, Deska Prayoga Fauzi

    2017-01-01

    In Indonesia ginger was usually used as a seasoning for dishes, an ingredient for beverage and a source of herbal medicines. Beside raw usage, ginger can be processed to obtain the essential oil which has many advantages such as proven to be an active antimicrobial and having an antioxidant ability. There are a lot of methods to extract essential oil from ginger, one of which is steam distillation. The aim of the current study was to investigate the effect of variation of time process and steam flow rate in the yield on ginger essential oil steam distillation extraction process. It was found that the best operation condition was 0.35 ml/s as the steam flow rate which yields 2.43% oil. The optimum time process was predicted at 7.5 hours. The composition of the oil was varied depend on the flow rate and every flow rate has its own major component contained in the oil. Curcumene composition in the oil was increased as increased steam flow rate applied, but the composition of camphene was decreased along with the increasing steam flow rate.

  15. Experiments in a flighted conveyor comparing shear rates in compressed versus free surface flows

    NASA Astrophysics Data System (ADS)

    Pohlman, Nicholas; Higgins, Hannah; Krupiarz, Kamila; O'Connor, Ryan

    2017-11-01

    Uniformity of granular flow rate is critical in industry. Experiments in a flighted conveyor system aim to fill a gap in knowledge of achieving steady mass flow rate by correlating velocity profile data with mass flow rate measurements. High speed images were collected for uniformly-shaped particles in a bottom-driven flow conveyor belt system from which the velocity profiles can be generated. The correlation of mass flow rates from the velocity profiles to the time-dependent mass measurements will determine energy dissipation rates as a function of operating conditions. The velocity profiles as a function of the size of the particles, speed of the belt, and outlet size, will be compared to shear rate relationships found in past experiments that focused on gravity-driven systems. The dimension of the linear shear and type of decaying transition to the stationary bed may appear different due to the compression versus dilation space in open flows. The application of this research can serve to validate simulations in discrete element modeling and physically demonstrate a process that can be further developed and customized for industry applications, such as feeding a biomass conversion reactor. Sponsored by NIU's Office of Student Engagement and Experiential Learning.

  16. Effects of seawater flow rate and evaporation temperature on performance of Sherbet type ice making machine

    NASA Astrophysics Data System (ADS)

    Son, C. H.; Yoon, J. I.; Choi, K. H.; Lee, H. K.; Lee, K. S.; Moon, C. G.; Seol, S. H.

    2018-01-01

    This study analyzes performance of the sherbet type ice making machine using seawater with respect to seawater volumetric flow rate, evaporation temperature, cooling water inlet and seawater inlet temperature as variables. Cooling water inlet and seawater inlet temperature are set considering average temperature of South Korea and the equator regions. Volumetric flow rate of seawater range is 0.75-1.75 LPM in this experiment. The results obtained from the experiment are as follows. As the seawater volumetric flow rate increases, or seawater inlet temperature increases, evaporation capacity tends to increase. At the point of seawater inlet temperature of 27°C and volumetric flow rate of 1.0LPM, evaporation capacity is over 2kW. On the other hand, results of COP change tendency are different from that of evaporation capacity. It appears to increase until volumetric flow rate of 1.0LPM, and decrease gradually from volumetric flow rate of 1.5LPM. This is due to the increase of compressor work to keep the evaporation pressure in accordance with the temperature of heat source. As the evaporation temperature decreases from -8 to -15°C, the evaporation capacity increases, but the COP decreases.

  17. A microfluidic device for simultaneous measurement of viscosity and flow rate of blood in a complex fluidic network

    PubMed Central

    Jun Kang, Yang; Yeom, Eunseop; Lee, Sang-Joon

    2013-01-01

    Blood viscosity has been considered as one of important biophysical parameters for effectively monitoring variations in physiological and pathological conditions of circulatory disorders. Standard previous methods make it difficult to evaluate variations of blood viscosity under cardiopulmonary bypass procedures or hemodialysis. In this study, we proposed a unique microfluidic device for simultaneously measuring viscosity and flow rate of whole blood circulating in a complex fluidic network including a rat, a reservoir, a pinch valve, and a peristaltic pump. To demonstrate the proposed method, a twin-shaped microfluidic device, which is composed of two half-circular chambers, two side channels with multiple indicating channels, and one bridge channel, was carefully designed. Based on the microfluidic device, three sequential flow controls were applied to identify viscosity and flow rate of blood, with label-free and sensorless detection. The half-circular chamber was employed to achieve mechanical membrane compliance for flow stabilization in the microfluidic device. To quantify the effect of flow stabilization on flow fluctuations, a formula of pulsation index (PI) was analytically derived using a discrete fluidic circuit model. Using the PI formula, the time constant contributed by the half-circular chamber is estimated to be 8 s. Furthermore, flow fluctuations resulting from the peristaltic pumps are completely removed, especially under periodic flow conditions within short periods (T < 10 s). For performance demonstrations, the proposed method was applied to evaluate blood viscosity with respect to varying flow rate conditions [(a) known blood flow rate via a syringe pump, (b) unknown blood flow rate via a peristaltic pump]. As a result, the flow rate and viscosity of blood can be simultaneously measured with satisfactory accuracy. In addition, the proposed method was successfully applied to identify the viscosity of rat blood, which circulates in a complex fluidic network. These observations confirm that the proposed method can be used for simultaneous measurement of viscosity and flow rate of whole blood circulating in the complex fluid network, with sensorless and label-free detection. Furthermore, the proposed method will be used in evaluating variations in the viscosity of human blood during cardiopulmonary bypass procedures or hemodialysis. PMID:24404074

  18. A microfluidic device for simultaneous measurement of viscosity and flow rate of blood in a complex fluidic network.

    PubMed

    Jun Kang, Yang; Yeom, Eunseop; Lee, Sang-Joon

    2013-01-01

    Blood viscosity has been considered as one of important biophysical parameters for effectively monitoring variations in physiological and pathological conditions of circulatory disorders. Standard previous methods make it difficult to evaluate variations of blood viscosity under cardiopulmonary bypass procedures or hemodialysis. In this study, we proposed a unique microfluidic device for simultaneously measuring viscosity and flow rate of whole blood circulating in a complex fluidic network including a rat, a reservoir, a pinch valve, and a peristaltic pump. To demonstrate the proposed method, a twin-shaped microfluidic device, which is composed of two half-circular chambers, two side channels with multiple indicating channels, and one bridge channel, was carefully designed. Based on the microfluidic device, three sequential flow controls were applied to identify viscosity and flow rate of blood, with label-free and sensorless detection. The half-circular chamber was employed to achieve mechanical membrane compliance for flow stabilization in the microfluidic device. To quantify the effect of flow stabilization on flow fluctuations, a formula of pulsation index (PI) was analytically derived using a discrete fluidic circuit model. Using the PI formula, the time constant contributed by the half-circular chamber is estimated to be 8 s. Furthermore, flow fluctuations resulting from the peristaltic pumps are completely removed, especially under periodic flow conditions within short periods (T < 10 s). For performance demonstrations, the proposed method was applied to evaluate blood viscosity with respect to varying flow rate conditions [(a) known blood flow rate via a syringe pump, (b) unknown blood flow rate via a peristaltic pump]. As a result, the flow rate and viscosity of blood can be simultaneously measured with satisfactory accuracy. In addition, the proposed method was successfully applied to identify the viscosity of rat blood, which circulates in a complex fluidic network. These observations confirm that the proposed method can be used for simultaneous measurement of viscosity and flow rate of whole blood circulating in the complex fluid network, with sensorless and label-free detection. Furthermore, the proposed method will be used in evaluating variations in the viscosity of human blood during cardiopulmonary bypass procedures or hemodialysis.

  19. Flow rate limitation in open wedge channel under microgravity

    NASA Astrophysics Data System (ADS)

    Wei, YueXing; Chen, XiaoQian; Huang, YiYong

    2013-08-01

    A study of flow rate limitation in an open wedge channel is reported in this paper. Under microgravity condition, the flow is controlled by the convection and the viscosity in the channel as well as the curvature of the liquid free surface. A maximum flow rate is achieved when the curvature cannot balance the pressure difference leading to a collapse of the free surface. A 1-dimensional theoretical model is used to predict the critical flow rate and calculate the shape of the free surface. Computational Fluid Dynamics tool is also used to simulate the phenomenon. Results show that the 1-dimensional model overestimates the critical flow rate because extra pressure loss is not included in the governing equation. Good agreement is found in 3-dimensional simulation results. Parametric study with different wedge angles and channel lengths show that the critical flow rate increases with increasing the cross section area; and decreases with increasing the channel length. The work in this paper can help understand the surface collapsing without gravity and for the design in propellant management devices in satellite tanks.

  20. Effects of shear flow on phase nucleation and crystallization.

    PubMed

    Mura, Federica; Zaccone, Alessio

    2016-04-01

    Classical nucleation theory offers a good framework for understanding the common features of new phase formation processes in metastable homogeneous media at rest. However, nucleation processes in liquids are ubiquitously affected by hydrodynamic flow, and there is no satisfactory understanding of whether shear promotes or slows down the nucleation process. We developed a classical nucleation theory for sheared systems starting from the molecular level of the Becker-Doering master kinetic equation and we analytically derived a closed-form expression for the nucleation rate. The theory accounts for the effect of flow-mediated transport of molecules to the nucleus of the new phase, as well as for the mechanical deformation imparted to the nucleus by the flow field. The competition between flow-induced molecular transport, which accelerates nucleation, and flow-induced nucleus straining, which lowers the nucleation rate by increasing the nucleation energy barrier, gives rise to a marked nonmonotonic dependence of the nucleation rate on the shear rate. The theory predicts an optimal shear rate at which the nucleation rate is one order of magnitude larger than in the absence of flow.

  1. Effects of Temperature and Strain Rate on Tensile Deformation Behavior of 9Cr-0.5Mo-1.8W-VNb Ferritic Heat-Resistant Steel

    NASA Astrophysics Data System (ADS)

    Guo, Xiaofeng; Weng, Xiaoxiang; Jiang, Yong; Gong, Jianming

    2017-09-01

    A series of uniaxial tensile tests were carried out at different strain rate and different temperatures to investigate the effects of temperature and strain rate on tensile deformation behavior of P92 steel. In the temperature range of 30-700 °C, the variations of flow stress, average work-hardening rate, tensile strength and ductility with temperature all show three temperature regimes. At intermediate temperature, the material exhibited the serrated flow behavior, the peak in flow stress, the maximum in average work-hardening rate, and the abnormal variations in tensile strength and ductility indicates the occurrence of DSA, whereas the sharp decrease in flow stress, average work-hardening rate as well as strength values, and the remarkable increase in ductility values with increasing temperature from 450 to 700 °C imply that dynamic recovery plays a dominant role in this regime. Additionally, for the temperature ranging from 550 to 650 °C, a significant decrease in flow stress values is observed with decreasing in strain rate. This phenomenon suggests the strain rate has a strong influence on flow stress. Based on the experimental results above, an Arrhenius-type constitutive equation is proposed to predict the flow stress.

  2. Effect of the SiCl₄ Flow Rate on SiBN Deposition Kinetics in SiCl₄-BCl₃-NH₃-H₂-Ar Environment.

    PubMed

    Li, Jianping; Qin, Hailong; Liu, Yongsheng; Ye, Fang; Li, Zan; Cheng, Laifei; Zhang, Litong

    2017-06-07

    To improve the thermal and mechanical stability of SiC f /SiC or C/SiC composites with SiBN interphase, SiBN coating was deposited by low pressure chemical vapor deposition (LPCVD) using SiCl₄-BCl₃-NH₃-H₂-Ar gas system. The effect of the SiCl₄ flow rate on deposition kinetics was investigated. Results show that deposition rate increases at first and then decreases with the increase of the SiCl₄ flow rate. The surface of the coating is a uniform cauliflower-like structure at the SiCl₄ flow rate of 10 mL/min and 20 mL/min. The surface is covered with small spherical particles when the flow rate is 30 mL/min. The coatings deposited at various SiCl₄ flow rates are all X-ray amorphous and contain Si, B, N, and O elements. The main bonding states are B-N, Si-N, and N-O. B element and B-N bonding decrease with the increase of SiCl₄ flow rate, while Si element and Si-N bonding increase. The main deposition mechanism refers to two parallel reactions of BCl₃+NH₃ and SiCl₄+NH₃. The deposition process is mainly controlled by the reaction of BCl₃+NH₃.

  3. Pigtail catheters used for percutaneous fluid drainage: comparison of performance characteristics.

    PubMed

    Macha, Douglas B; Thomas, John; Nelson, Rendon C

    2006-03-01

    To compare the performance characteristics of various single-lumen all-purpose pigtail drainage catheters. The following parameters were compared: flow rates between catheters of the same size, whether changing the fluid viscosity has any effect on catheter comparisons, the effect on flow of leaving an open three-way stopcock in the drainage pathway, the tendency of the catheters to kink, and catheter patency after kinking, as measured according to flow. All-purpose 8.0-, 8.3-, and 8.5-F (collectively referred to as 8-F); 10.0-, 10.2-, and 10.3-F (collectively referred to as 10-F); and 12.0-F pigtail drainage catheters from three manufacturers were evaluated. Data were compared by using two-tailed t tests after normal distributions were confirmed. P < .05 was considered to represent a significant difference. At comparison of the 8-F catheters, the C.R. Bard catheters demonstrated better flow rates than the Cook and Boston Scientific devices. Among the 10-F catheters, there were no significant differences in the flow rates of fluid with viscosity equivalent to that of water between the C.R. Bard and Boston Scientific catheters; however, both these catheter types demonstrated significantly (P < .05) better flow rates than the Cook devices. Among the 12-F catheters, the C.R. Bard catheters demonstrated significantly (P < .05) better flow rates than the other two catheter types. Changing the fluid viscosity caused no changes in comparison results. In all catheter groups, the presence of a stopcock significantly (P < .05) impaired flow. None of the evaluated catheters demonstrated a clear advantage in terms of patency or susceptibility to kinking. At comparison of the in vitro performances of catheters from different manufacturers, the C.R. Bard 8.0-F and Cook 10.2-F catheters had comparable flow rates, and flow rates through the C.R. Bard and Boston Scientific 10.0-F catheters were comparable to flow rates through the Cook and Boston Scientific 12.0-F catheters. Varying viscosity had no effect on comparisons of catheter flow rates; however, a stopcock between the vacuum source and the catheter was noted to impair flow rates in all brands and sizes of evaluated catheters. Copyright RSNA, 2006.

  4. Efficiency of the Thermal Jacket on the Delivered Temperature of Prewarmed Crystalloid Intravenous Fluid

    DTIC Science & Technology

    1989-01-01

    intervals over a 60 minute period at flow rates of 100, 250, 500, 750, and 1,000 ml/hr. Analysis of variance showed a highly significant group effect with a...significant difference between all groups except Group 3 and Group 4. Analysis of - .riance aiso showed a highly significant flow rate effect on...as effective as the conventional method of delivering warmed fluids. Also, within the range of flow rates studied, faster flow rates tended to yield a

  5. SEASONAL VARIATIONS IN HUMAN PAROTID FLUID FLOW RATE IN A SUBTROPICAL CLIMATE.

    DTIC Science & Technology

    Parotid fluid was collected under conditions of very minimal stimulation from 3,868 systemically healthy young adult males over a period of two...calendar years. The study was carried out in a subtropical climate in which the only thermal discomfort resulted from the summer heat. Parotid flow rate...fall. During the summer months the mean rate of parotid flow was 0.031 ml./minute; during the winter the flow rate mean increased by 35% to 0.042 ml

  6. Stability analysis for capillary channel flow: 1d and 3d computations

    NASA Astrophysics Data System (ADS)

    Grah, Aleksander; Klatte, Jörg; Dreyer, Michael E.

    The subject of the presentation are numerical studies on capillary channel flow, based on results of the sounding rocket TEXUS experiments. The flow through a capillary channel is established by a gear pump at the outlet. The channel, consists of two parallel glass plates with a width of 25 mm, a gap of 10 mm and a length of 12 mm. The meniscus of a compensation tube maintains a constant system pressure. Steady and dynamic pressure effects in the system force the surfaces to bend inwards. A maximum flow rate is achieved when the free surface collapses and gas ingestion occurs at the outlet. This critical flow rate depends on the channel geometry, the flow regime and the liquid properties. The aim of the experiments is the determination of the free surface shape and to find the maximum flow rate. In order to study the unsteady liquid loop behavior, a dimensionless one-dimensional model and a corresponding three-dimensional model were developed. The one-dimensional model is based on the unsteady Bernoulli equation, the unsteady continuity equation and geometrical conditions for the surface curvature and the flow cross-section. The experimental and evaluated contour data show good agreement for a sequence of transient flow rate perturbations. In the case of steady flow at maximum flow rate, when the "choking" effect occurs, the surfaces collapse and cause gas ingestion into the channel. This effect is related to the Speed Index. At the critical flow rate the Speed Index reaches the value 1, in analogy to the Mach Number. Unsteady choking does not necessarily cause surface collapse. We show, that temporarily Speed Index values exceeding One may be achieved for a perfectly stable supercritical dynamic flow. As a supercritical criterion for the dynamic free surface stability we define a Dynamic Index considering the local capillary pressure and the convective pressure, which is a function of the local velocity. The Dynamic Index is below One for stable flow while D = 1 indicates surface collapse. This studies lead to a stability diagram, which defines the limits of flow dynamics and the maximum unsteady flow rate.

  7. Development of a flow controller for long-term sampling of gases and vapors using evacuated canisters.

    PubMed

    Rossner, Alan; Farant, Jean Pierre; Simon, Philippe; Wick, David P

    2002-11-15

    Anthropogenic activities contribute to the release of a wide variety of volatile organic compounds (VOC) into microenvironments. Developing and implementing new air sampling technologies that allow for the characterization of exposures to VOC can be useful for evaluating environmental and health concerns arising from such occurrences. A novel air sampler based on the use of a capillary flow controller connected to evacuated canisters (300 mL, 1 and 6 L) was designed and tested. The capillary tube, used to control the flow of air, is a variation on a sharp-edge orifice flow controller. It essentially controls the velocity of the fluid (air) as a function of the properties of the fluid, tube diameter and length. A model to predict flow rate in this dynamic system was developed. The mathematical model presented here was developed using the Hagen-Poiseuille equation and the ideal gas law to predict flow into the canisters used to sample for long periods of time. The Hagen-Poiseuille equation shows the relationship between flow rate, pressure gradient, capillary resistance, fluid viscosity, capillary length and diameter. The flow rates evaluated were extremely low, ranging from 0.05 to 1 mL min(-1). The model was compared with experimental results and was shown to overestimate the flow rate. Empirical equations were developed to more accurately predict flow for the 300 mL, 1 and 6 L canisters used for sampling periods ranging from several hours to one month. The theoretical and observed flow rates for different capillary geometries were evaluated. Each capillary flow controller geometry that was tested was found to generate very reproducible results, RSD < 2%. Also, the empirical formulas developed to predict flow rate given a specified diameter and capillary length were found to predict flow rate within 6% of the experimental data. The samplers were exposed to a variety of airborne vapors that allowed for comparison of the effectiveness of capillary flow controllers to sorbent samplers and to an online gas chromatograph. The capillary flow controller was found to exceed the performance of the sorbent samplers in this comparison.

  8. Improved analysis of transient temperature data from permanent down-hole gauges (PDGs)

    NASA Astrophysics Data System (ADS)

    Zhang, Yiqun; Zheng, Shiyi; Wang, Qi

    2017-08-01

    With the installation of permanent down-hole gauges (PDGs) during oil field development, large volumes of high resolution and continuous down-hole information are obtainable. The interpretation of these real-time temperature and pressure data can optimize well performance, provide information about the reservoir and continuously calibrate the reservoir model. Although the dynamic temperature data have been interpreted in practice to predict flow profiling and provide characteristic information of the reservoir, almost all of the approaches rely on established non-isothermal models which depend on thermodynamic parameters. Another problem comes from the temperature transient analysis (TTA), which is underutilized compared with pressure transient analysis (PTA). In this study, several model-independent methods of TTA were performed. The entire set of PDG data consists of many flow events. By utilizing the wavelet transform, the exact points of flow-rate changes can be located. The flow regime changes, for example, from early time linear flow to later time pseudo-radial flow, among every transient period with constant flow-rate. For the early time region (ETR) that is caused by flow-rate change operations, the TTA, along with the PTA can greatly reduce the uncertainties in flow regime diagnosis. Then, the temperature variations during ETR were examined to infer the true reservoir temperature history, and the relationships between the wavelet detailed coefficients and the flow-rate changes were analysed. For the scenarios with constant reservoir-well parameters, the detailed flow-rate history can be generated by calculating the coefficient of relationship in advance. For later times, the flow regime changes to pseudo-radial flow. An analytical solution was introduced to describe the sand-face temperature. The formation parameters, such as permeability and skin factor, were estimated with the previously calculated flow-rate. It is necessary to analyse temperature variation to overcome data limitation problems when information from other down-hole tools (e.g. expensive but unstable flow meters) is insufficient. This study shows the success in wellbore storage regime diagnosis, flow-rate history reconstruction, and formation parameters estimation using transient temperature data.

  9. Well logging interpretation of production profile in horizontal oil-water two phase flow pipes

    NASA Astrophysics Data System (ADS)

    Zhai, Lu-Sheng; Jin, Ning-De; Gao, Zhong-Ke; Zheng, Xi-Ke

    2012-03-01

    Due to the complicated distribution of local velocity and local phase hold up along the radial direction of pipe in horizontal oil-water two phase flow, it is difficult to measure the total flow rate and phase volume fraction. In this study, we carried out dynamic experiment in horizontal oil-water two phases flow simulation well by using combination measurement system including turbine flowmeter with petal type concentrating diverter, conductance sensor and flowpassing capacitance sensor. According to the response resolution ability of the conductance and capacitance sensor in different range of total flow rate and water-cut, we use drift flux model and statistical model to predict the partial phase flow rate, respectively. The results indicate that the variable coefficient drift flux model can self-adaptively tone the model parameter according to the oil-water two phase flow characteristic, and the prediction result of partial phase flow rate of oil-water two phase flow is of high accuracy.

  10. THE EFFECT OF RATE OF GLAND FUNCTION ON PAROTID FLUID URIC ACID LEVELS.

    DTIC Science & Technology

    Paired parotid fluid samples were collected without exogenous stimulation and at 5 different gustation-induced rates of flow. Enzymatic uric acid...diminished as flow rate increased. It is suggested that parotid fluid samples for uric acid analysis should be collected at flow rates of 0.7 ml./min. or more. (Author)

  11. Device accurately measures and records low gas-flow rates

    NASA Technical Reports Server (NTRS)

    Branum, L. W.

    1966-01-01

    Free-floating piston in a vertical column accurately measures and records low gas-flow rates. The system may be calibrated, using an adjustable flow-rate gas supply, a low pressure gage, and a sequence recorder. From the calibration rates, a nomograph may be made for easy reduction. Temperature correction may be added for further accuracy.

  12. Assessing the effusion rate of lava flows from their thermal radiated energy: theoretical study and lab-scale experiments

    NASA Astrophysics Data System (ADS)

    Garel, F.; Kaminski, E.; Tait, S.; Limare, A.

    2010-12-01

    A quantitative monitoring of lava flow is required to manage a volcanic crisis, in order to assess where the flow will go, and when will it stop. As the spreading of lava flows is mainly controlled by its rheology and the eruptive mass flux, the key question is how to evaluate them during the eruption (rather than afterwards.) A relationship between the lava flow temperature and the eruption rate is likely to exist, based on the first-order argument that higher eruption rates should correspond to larger energy radiated by a lava flow. The semi-empirical formula developed by Harris and co-workers (e.g. Harris et al., 2007) is used to estimate lava flow rate from satellite observations. However, the complete theoretical bases of this technique, especially its domain of validity, remain to be firmly established. Here we propose a theoretical study of the cooling of a viscous axisymmetric gravity current fed at constant flux rate to investigate whether or not this approach can and/or should be refined and/or modify to better assess flow rates. Our study focuses on the influence of boundary conditions at the surface of the flow, where cooling can occur both by radiation and convection, and at the base of the flow. Dimensionless numbers are introduced to quantify the relative interplay between the model parameters, such as the lava flow rate and the efficiency of the various cooling processes (conduction, convection, radiation.) We obtain that the thermal evolution of the flow can be described as a two-stage evolution. After a transient phase of dynamic cooling, the flow reaches a steady state, characterized by a balance between surface and base cooling and heat advection in the flow, in which the surface temperature structure is constant. The duration of the transient phase and the radiated energy in the steady regime are shown to be a function of the dimensionless numbers. In the case of lava flows, we obtain that the steady state regime is reached after a few days. In this regime, a thermal image provides a consistent estimate of the flow rate if the external cooling conditions are reasonably well constrained.

  13. The effect of carbon dioxide flow rate on the euthanasia of laboratory mice.

    PubMed

    Moody, C M; Chua, B; Weary, D M

    2014-10-01

    Laboratory rodents are commonly euthanized by exposure to gradually increasing concentrations of carbon dioxide (CO2). Current recommended flow rates range between 10 and 30% chamber vol/min and result in insensibility before exposure to painful concentrations (<40%). However, this method causes dyspnea, indicated by deep, rapid breathing. In humans dyspnea is associated with a negative affective experience. Sensations of dyspnea may explain why rodents find CO2 concentrations >3% aversive. This study aimed to assess the effect of CO2 flow rates on time between the onset of dyspnea and various measures of insensibility (recumbency, loss of the righting reflex and loss of the pedal withdrawal reflex) to identify flow rates that minimize the potential experience of dyspnea. The results of this study indicate that a flow rate of 50% chamber vol/min, while holding the CO2 cage concentration just below 40%, minimizes the interval between the onset of labored breathing and recumbency. Using a 50% flow rate this interval averaged (± SE) 30.3 ± 2.9 s versus 49.7 ± 2.9 s at 20% chamber vol/min (F3,22 = 7.83, P = 0.0013). Similarly, the interval between the onset of labored breathing and loss of the righting reflex averaged 38.2 ± 2.4 s at a flow rate of 50% versus 59.2 ± 2.4 s at 20% chamber vol/min of CO2 (F3,22 = 13.62, P < 0.0001). We conclude that higher flow rates reduce the duration of dyspnea, but even at the highest flow rate mice experience more than 30 s between the onset of dyspnea and the most conservative estimate of insensibility. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  14. Performance of a new carbon dioxide absorbent, Yabashi lime® as compared to conventional carbon dioxide absorbent during sevoflurane anesthesia in dogs.

    PubMed

    Kondoh, Kei; Atiba, Ayman; Nagase, Kiyoshi; Ogawa, Shizuko; Miwa, Takashi; Katsumata, Teruya; Ueno, Hiroshi; Uzuka, Yuji

    2015-08-01

    In the present study, we compare a new carbon dioxide (CO2) absorbent, Yabashi lime(®) with a conventional CO2 absorbent, Sodasorb(®) as a control CO2 absorbent for Compound A (CA) and Carbon monoxide (CO) productions. Four dogs were anesthetized with sevoflurane. Each dog was anesthetized with four preparations, Yabashi lime(®) with high or low-flow rate of oxygen and control CO2 absorbent with high or low-flow rate. CA and CO concentrations in the anesthetic circuit, canister temperature and carbooxyhemoglobin (COHb) concentration in the blood were measured. Yabashi lime(®) did not produce CA. Control CO2 absorbent generated CA, and its concentration was significantly higher in low-flow rate than a high-flow rate. CO was generated only in low-flow rate groups, but there was no significance between Yabashi lime(®) groups and control CO2 absorbent groups. However, the CO concentration in the circuit could not be detected (≤5ppm), and no change was found in COHb level. Canister temperature was significantly higher in low-flow rate groups than high-flow rate groups. Furthermore, in low-flow rate groups, the lower layer of canister temperature in control CO2 absorbent group was significantly higher than Yabashi lime(®) group. CA and CO productions are thought to be related to the composition of CO2 absorbent, flow rate and canister temperature. Though CO concentration is equal, it might be safer to use Yabashi lime(®) with sevoflurane anesthesia in dogs than conventional CO2 absorbent at the point of CA production.

  15. Injection characteristics study of high-pressure direct injector for Compressed Natural Gas (CNG) using experimental and analytical method

    NASA Astrophysics Data System (ADS)

    Taha, Z.; Rahim, MF Abdul; Mamat, R.

    2017-10-01

    The injection characteristics of direct injector affect the mixture formation and combustion processes. In addition, the injector is converted from gasoline operation for CNG application. Thus measurement of CNG direct injector mass flow rate was done by independently tested a single injector on a test bench. The first case investigated the effect of CNG injection pressure and the second case evaluate the effect of pulse-width of injection duration. An analytical model was also developed to predict the mass flow rate of the injector. The injector was operated in a choked condition in both the experiments and simulation studies. In case 1, it was shown that mass flow rate through the injector is affected by injection pressure linearly. Based on the tested injection pressure of 20 bar to 60 bar, the resultant mass flow rate are in the range of 0.4 g/s to 1.2 g/s which are met with theoretical flow rate required by the engine. However, in Case 2, it was demonstrated that the average mass flow rate at short injection durations is lower than recorded in Case 1. At injection pressure of 50 bar, the average mass flow rate for Case 2 and Case 1 are 0.7 g/s and 1.1 g/s respectively. Also, the measured mass flow rate at short injection duration showing a fluctuating data in the range of 0.2 g/s - 1.3 g/s without any noticeable trends. The injector model able to predict the trend of the mass flow rate at different injection pressure but unable to track the fluctuating trend at short injection duration.

  16. Criteria for choosing an intravenous infusion line intended for multidrug infusion in anaesthesia and intensive care units.

    PubMed

    Maiguy-Foinard, Aurélie; Genay, Stéphanie; Lannoy, Damien; Barthélémy, Christine; Lebuffe, Gilles; Debaene, Bertrand; Odou, Pascal; Décaudin, Bertrand

    2017-02-01

    The aims are to identify critical parameters influencing the drug mass flow rate of infusion delivery to patients during multidrug infusion and to discuss their clinical relevance. A review of literature was conducted in January 2016 using Medline, Google Scholar, ScienceDirect, Web of Science and Scopus online databases. References relating to the accuracy of fluid delivery via gravity-flow intravenous (IV) infusion systems and positive displacement pumps, components of IV administration sets, causes of flow rate variability, potential complications due to flow rate variability, IV therapies especially at low flow rates and drug compatibilities were considered relevant. Several parameters impact the delivery of drugs and fluids by IV infusion. Among them are the components of infusion systems that particularly influence the flow rate of medications and fluids being delivered. By their conception, they may generate significant start-up delays and flow rate variability. Performing multidrug infusion requires taking into account two main points: the common dead volume of drugs delivered simultaneously with potential consequences on the accuracy and amount of drug delivery and the prevention of drug incompatibilities and their clinical effects. To prevent the potentially serious effects of flow rate variability on patients, clinicians should receive instruction on the fluid dynamics of an IV administration set and so be able to take steps to minimise flow rate changes during IV therapy. Copyright © 2016 Société française d’anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.

  17. Advancement of In-Flight Alumina Powder Spheroidization Process with Water Droplet Injection Using a Small Power DC-RF Hybrid Plasma Flow System

    NASA Astrophysics Data System (ADS)

    Jang, Juyong; Takana, Hidemasa; Park, Sangkyu; Nishiyama, Hideya

    2012-09-01

    The correlation between plasma thermofluid characteristics and alumina powder spheroidization processes with water droplet injection using a small power DC-RF hybrid plasma flow system was experimentally clarified. Micro-sized water droplets with a low water flow rate were injected into the tail of thermal plasma flow so as not to disturb the plasma flow directly. Injected water droplets were vaporized in the thermal plasma flow and were transported upstream in the plasma flow to the torch by the backflow. After dissociation of water, the production of hydrogen was detected by the optical emission spectroscopy in the downstream RF plasma flow. The emission area of the DC plasma jet expanded and elongated in the vicinity of the RF coils. Additionally, the emission area of RF plasma flow enlarged and was visible as red emission in the downstream RF plasma flow in the vicinity below the RF coils due to hydrogen production. Therefore, the plasma flow mixed with produced hydrogen increased the plasma enthalpy and the highest spheroidization rate of 97% was obtained at a water flow rate of 15 Sm l/min and an atomizing gas flow rate of 8 S l/min using a small power DC-RF hybrid plasma flow system.

  18. Real-time three-dimensional color Doppler echocardiography for characterizing the spatial velocity distribution and quantifying the peak flow rate in the left ventricular outflow tract

    NASA Technical Reports Server (NTRS)

    Tsujino, H.; Jones, M.; Shiota, T.; Qin, J. X.; Greenberg, N. L.; Cardon, L. A.; Morehead, A. J.; Zetts, A. D.; Travaglini, A.; Bauer, F.; hide

    2001-01-01

    Quantification of flow with pulsed-wave Doppler assumes a "flat" velocity profile in the left ventricular outflow tract (LVOT), which observation refutes. Recent development of real-time, three-dimensional (3-D) color Doppler allows one to obtain an entire cross-sectional velocity distribution of the LVOT, which is not possible using conventional 2-D echo. In an animal experiment, the cross-sectional color Doppler images of the LVOT at peak systole were derived and digitally transferred to a computer to visualize and quantify spatial velocity distributions and peak flow rates. Markedly skewed profiles, with higher velocities toward the septum, were consistently observed. Reference peak flow rates by electromagnetic flow meter correlated well with 3-D peak flow rates (r = 0.94), but with an anticipated underestimation. Real-time 3-D color Doppler echocardiography was capable of determining cross-sectional velocity distributions and peak flow rates, demonstrating the utility of this new method for better understanding and quantifying blood flow phenomena.

  19. How does natural groundwater flow affect CO2 dissolution in saline aquifers?

    NASA Astrophysics Data System (ADS)

    Rosenzweig, R.; Michel-Meyer, I.; Tsinober, A.; Shavit, U.

    2017-12-01

    The dissolution of supercritical CO2 in aquifer brine is one of the most important trapping mechanisms in CO2 geological storage. Diffusion-limited dissolution is a very slow process. However, since the CO2-rich water is slightly denser than the CO2-free water, when CO2-free water is overlaid by heavier CO2-rich water, convective instability results in fingers of dense CO2-rich water that propagate downwards, causing CO2-unsaturated water to move upwards. This convection process significantly accelerates the dissolution rate of CO2 into the aquifer water.Most previous works have neglected the effect of natural groundwater flow and assumed it has no effect on the dissolution dynamics. However, it was found that in some of the saline aquifers groundwater flow rate, although small, is not zero. In this research, we study the effect of groundwater flow on dissolution by performing laboratory experiments in a bead pack cell using a mixture of methanol and ethylene-glycol as a CO2 analog while varying the water horizontal flow rate. We find that water horizontal flow decreases the number of fingers, their wavelength and their propagation velocity. When testing high water flow rates, no fingers were developed and the dissolution process was entirely diffusive. The effect of water flow on the dissolution rate did not show a clear picture. When increasing the horizontal flow rate the convective dissolution flux slightly decreased and then increased again. It seems that the combination of density-driven flow, water horizontal flow, mechanical dispersion and molecular diffusion affect the dissolution rate in a complex and non-monotonic manner. These intriguing dynamics should be further studied to understand their effect on dissolution trapping.

  20. Probe measures gas and liquid mass flux in high mass flow ratio two-phase flows

    NASA Technical Reports Server (NTRS)

    Burick, R. J.

    1972-01-01

    Deceleration probe constructed of two concentric tubes with separator inlet operates successfully in flow fields where ratio of droplet flow rate to gas flow rate ranges from 1.0 to 20, and eliminates problems of local flow field disturbances and flooding. Probe is effective tool for characterization of liquid droplet/gas spray fields.

  1. Method and apparatus for measuring the mass flow rate of a fluid

    DOEpatents

    Evans, Robert P.; Wilkins, S. Curtis; Goodrich, Lorenzo D.; Blotter, Jonathan D.

    2002-01-01

    A non invasive method and apparatus is provided to measure the mass flow rate of a multi-phase fluid. An accelerometer is attached to a pipe carrying a multi-phase fluid. Flow related measurements in pipes are sensitive to random velocity fluctuations whose magnitude is proportional to the mean mass flow rate. An analysis of the signal produced by the accelerometer shows a relationship between the mass flow of a fluid and the noise component of the signal of an accelerometer. The noise signal, as defined by the standard deviation of the accelerometer signal allows the method and apparatus of the present invention to non-intrusively measure the mass flow rate of a multi-phase fluid.

  2. Nonpoint Pollution Discharge Permit Testing and Control Strategies at Naval Air Station Whidbey Island.

    DTIC Science & Technology

    1991-01-01

    the permit. Monthly maximum and average test results are submitted to the USEPA with an approximation of the weekly flow rate . The quantity of flow is...flow rate . The storm flow data and drainage system hydraulic capacity are being reviewed by Sajan. Inc., Seattle. Figure 2. Visible Soil Staining at...approach is to collect composite samples of the flow, which will reduce fluctuations and allow a more accu- rate determination of total loadings with

  3. Polarization curve measurements combined with potential probe sensing for determining current density distribution in vanadium redox-flow batteries

    NASA Astrophysics Data System (ADS)

    Becker, Maik; Bredemeyer, Niels; Tenhumberg, Nils; Turek, Thomas

    2016-03-01

    Potential probes are applied to vanadium redox-flow batteries for determination of effective felt resistance and current density distribution. During the measurement of polarization curves in 100 cm2 cells with different carbon felt compression rates, alternating potential steps at cell voltages between 0.6 V and 2.0 V are applied. Polarization curves are recorded at different flow rates and states of charge of the battery. Increasing compression rates lead to lower effective felt resistances and a more uniform resistance distribution. Low flow rates at high or low state of charge result in non-linear current density distribution with high gradients, while high flow rates give rise to a nearly linear behavior.

  4. Highlights of the high-temperature falling particle receiver project: 2012 - 2016

    NASA Astrophysics Data System (ADS)

    Ho, C. K.; Christian, J.; Yellowhair, J.; Jeter, S.; Golob, M.; Nguyen, C.; Repole, K.; Abdel-Khalik, S.; Siegel, N.; Al-Ansary, H.; El-Leathy, A.; Gobereit, B.

    2017-06-01

    A 1 MWt continuously recirculating falling particle receiver has been demonstrated at Sandia National Laboratories. Free-fall and obstructed-flow receiver designs were tested with particle mass flow rates of ˜1 - 7 kg/s and average irradiances up to 1,000 suns. Average particle outlet temperatures exceeded 700 °C for the free-fall tests and reached nearly 800 °C for the obstructed-flow tests, with peak particle temperatures exceeding 900 °C. High particle heating rates of ˜50 to 200 °C per meter of illuminated drop length were achieved for the free-fall tests with mass flow rates ranging from 1 - 7 kg/s and for average irradiances up to ˜ 700 kW/m2. Higher temperatures were achieved at the lower particle mass flow rates due to less shading. The obstructed-flow design yielded particle heating rates over 300 °C per meter of illuminated drop length for mass flow rates of 1 - 3 kg/s for irradiances up to ˜1,000 kW/m2. The thermal efficiency was determined to be ˜60 - 70% for the free-falling particle tests and up to ˜80% for the obstructed-flow tests. Challenges encountered during the tests include particle attrition and particle loss through the aperture, reduced particle mass flow rates at high temperatures due to slot aperture narrowing and increased friction, and deterioration of the obstructed-flow structures due to wear and oxidation. Computational models were validated using the test data and will be used in future studies to design receiver configurations that can increase the thermal efficiency.

  5. Columbus Payloads Flow Rate Anomalies

    NASA Technical Reports Server (NTRS)

    Quaranta, Albino; Bufano, Gaetana; DePalo, Savino; Holt, James M.; Szigetvari, Zoltan; Palumberi, Sergio; Hinderer, S.

    2011-01-01

    The Columbus Active Thermal Control System (ATCS) is the main thermal bus for the pressurized racks working inside the European laboratory. One of the ATCS goals is to provide proper water flow rate to each payload (P/L) by controlling actively the pressure drop across the common plenum distribution piping. Overall flow measurement performed by the Water Pump Assembly (WPA) is the only flow rate monitor available at system level and is not part of the feedback control system. At rack activation the flow rate provided by the system is derived on ground by computing the WPA flow increase. With this approach, several anomalies were raised during these 3 years on-orbit, with the indication of low flow rate conditions on the European racks FSL, BioLab, EDR and EPM. This paper reviews the system and P/Ls calibration approach, the anomalies occurred, the engineering evaluation on the measurement approach and the accuracy improvements proposed, the on-orbit test under evaluation with NASA and finally discusses possible short and long term solutions in case of anomaly confirmation.

  6. Different elution modes and field programming in gravitational field-flow fractionation. III. Field programming by flow-rate gradient generated by a programmable pump.

    PubMed

    Plocková, J; Chmelík, J

    2001-05-25

    Gravitational field-flow fractionation (GFFF) utilizes the Earth's gravitational field as an external force that causes the settlement of particles towards the channel accumulation wall. Hydrodynamic lift forces oppose this action by elevating particles away from the channel accumulation wall. These two counteracting forces enable modulation of the resulting force field acting on particles in GFFF. In this work, force-field programming based on modulating the magnitude of hydrodynamic lift forces was implemented via changes of flow-rate, which was accomplished by a programmable pump. Several flow-rate gradients (step gradients, linear gradients, parabolic, and combined gradients) were tested and evaluated as tools for optimization of the separation of a silica gel particle mixture. The influence of increasing amount of sample injected on the peak resolution under flow-rate gradient conditions was also investigated. This is the first time that flow-rate gradients have been implemented for programming of the resulting force field acting on particles in GFFF.

  7. Investigation of the effect of wall friction on the flow rate in 2D and 3D Granular Flow

    NASA Astrophysics Data System (ADS)

    Carballo-Ramirez, Brenda; Pleau, Mollie; Easwar, Nalini; Birwa, Sumit; Shah, Neil; Tewari, Shubha

    We have measured the mass flow rate of spherical steel spheres under gravity in vertical, straight-walled 2 and 3-dimensional hoppers, where the flow velocity is controlled by the opening size. Our measurements focus on the role of friction and its placement along the walls of the hopper. In the 2D case, an increase in the coefficient of static friction from μ = 0.2 to 0.6 is seen to decrease the flow rate significantly. We have changed the placement of frictional boundaries/regions from the front and back walls of the 2D hopper to the side walls and floor to investigate the relative importance of the different regions in determining the flow rate. Fits to the Beverloo equation show significant departure from the expected exponent of 1.5 in the case of 2D flow. In contrast, 3D flow rates do not show much dependence on wall friction and its placement. We compare the experimental data to numerical simulations of gravity driven hopper granular flow with varying frictional walls constructed using LAMMPS*. *http://lammps.sandia.gov Supported by NSF MRSEC DMR 0820506.

  8. The role of unsteady effusion rates on inflation in long-lived lava flow fields

    NASA Astrophysics Data System (ADS)

    Rader, E.; Vanderkluysen, L.; Clarke, A.

    2017-11-01

    The emission of volcanic gases and particles can have global and lasting environmental effects, but their timing, tempo, and duration can be problematic to quantify for ancient eruptions where real-time measurements are absent. Lava flows, for example, may be long-lasting, and their impact is controlled by the rate, tempo, and vigor of effusion. These factors are currently difficult to derive from the geologic record but can have large implications for the atmospheric impact of an eruption. We conducted a set of analogue experiments on lava flow inflation aiming at connecting lava morphologies preserved in the rock record to eruption tempo and dynamics through pulsating effusion rates. Inflation, a process where molten material is injected beneath the crust of an active lava flow and lifts it upwards, is a common phenomenon in basaltic volcanic systems. This mechanism requires three components: a) a coherent, insulating crust; b) a wide-spread molten core; and c) pressure built up beneath the crust from a sustained supply of molten material. Inflation can result in a lava flow growing tens of meters thick, even in flow fields that expand hundreds of square kilometers. It has been documented that rapid effusion rates tend to create channels and tubes, isolating the active part of the flow from the stagnant part, while slow effusion rates may cause crust to form quickly and seize up, forcing lava to overtop the crust. However, the conditions that allow for inflation of large flow fields have not previously been evaluated in terms of effusion rate. By using PEG 600 wax and a programmable pump, we observe how, by pulsating effusion rate, inflation occurs even in very low viscosity basaltic eruptions. We show that observations from inflating Hawaiian lava flows correlate well with experimental data and indicate that instantaneous effusion rates may have been 3 times higher than average effusion rates during the emplacement of the 23 January 1988 flow at Kīlauea (Hawai'i). The identification of a causal relationship between pulsating effusion rates and inflation may have implications for eruption tempo in the largest inflated flows: flood basalts.

  9. Minimal vascular flows cause strong heat sink effects in hepatic radiofrequency ablation ex vivo.

    PubMed

    Lehmann, Kai S; Poch, Franz G M; Rieder, Christian; Schenk, Andrea; Stroux, Andrea; Frericks, Bernd B; Gemeinhardt, Ole; Holmer, Christoph; Kreis, Martin E; Ritz, Jörg P; Zurbuchen, Urte

    2016-08-01

    The present paper aims to assess the lower threshold of vascular flow rate on the heat sink effect in bipolar radiofrequency ablation (RFA) ex vivo. Glass tubes (vessels) of 3.4 mm inner diameter were introduced in parallel to bipolar RFA applicators into porcine liver ex vivo. Vessels were perfused with flow rates of 0 to 1,500 ml/min. RFA (30 W power, 15 kJ energy input) was carried out at room temperature and 37°C. Heat sink effects were assessed in RFA cross sections by the decrease in ablation radius, area and by a high-resolution sector planimetry. Flow rates of 1 ml/min already caused a significant cooling effect (P ≤ 0.001). The heat sink effect reached a maximum at 10 ml/min (18.4 mm/s) and remained stable for flow rates up to 1,500 ml/min. Minimal vascular flows of ≥1 ml/min cause a significant heat sink effect in hepatic RFA ex vivo. A lower limit for volumetric flow rate was not found. The maximum of the heat sink effect was reached at a flow rate of 10 ml/min and remained stable for flow rates up to 1,500 ml/min. Hepatic inflow occlusion should be considered in RFA close to hepatic vessels. © 2016 Japanese Society of Hepato-Biliary-Pancreatic Surgery.

  10. Effect of viscoelasticity on the flow pattern and the volumetric flow rate in electroosmotic flows through a microchannel.

    PubMed

    Park, H M; Lee, W M

    2008-07-01

    Many lab-on-a-chip based microsystems process biofluids such as blood and DNA solutions. These fluids are viscoelastic and show extraordinary flow behaviors, not existing in Newtonian fluids. Adopting appropriate constitutive equations these exotic flow behaviors can be modeled and predicted reasonably using various numerical methods. In the present paper, we investigate viscoelastic electroosmotic flows through a rectangular straight microchannel with and without pressure gradient. It is shown that the volumetric flow rates of viscoelastic fluids are significantly different from those of Newtonian fluids under the same external electric field and pressure gradient. Moreover, when pressure gradient is imposed on the microchannel there appear appreciable secondary flows in the viscoelastic fluids, which is never possible for Newtonian laminar flows through straight microchannels. The retarded or enhanced volumetric flow rates and secondary flows affect dispersion of solutes in the microchannel nontrivially.

  11. Critical capillary channel flow

    NASA Astrophysics Data System (ADS)

    Grah, Aleksander; Klatte, Jörg; Dreyer, Michael E.

    The main subject are numerical studies on capillary channel flow, based on results of the sounding rocket experiments TEXUS 41/42. The flow through a capillary channel is established by a gear pump at the outlet. The channel, consists of two parallel glass plates with a width of 25 mm, a gap of 10 mm and a length of 12 mm. The meniscus of a compensation tube maintains a constant system pressure. Steady and dynamic pressure effects in the system force the surfaces to bend inwards. A maximum flow rate is achieved when the free surface collapses and gas ingestion occurs at the outlet. This critical flow rate depends on the channel geometry, the flow regime and the liquid properties. The aim of the experiments is the determination of the free surface shape and to find the maximum flow rate. In order to study the unsteady liquid loop behaviour, a dimensionless transient model was developed. It is based on the unsteady Bernoulli equation, the unsteady continuity equation and geometrical conditions for the surface curvature and the flow cross-section. The pressure is related to the curvature of the free liquid surface by the dimensionless Gauss-Laplace equation with two principal radii. The experimental and evaluated contour data shows good agreement for a sequence of transient flow rate perturbations. The surface oscillation frequencies and amplitudes can be predicted with quite high accuracy. The dynamic of the pump is defined by the increase of the flow rate in a time period. To study the unsteady system behavior in the "worst case", we use a perturbations related to the natural frequency of the oscillating liquid. In the case of steady flow at maximum flow rate, when the "choking" effect occurs, the surfaces collapse and cause gas ingestion into the channel. This effect is related to the Speed Index. At the critical flow rate the Speed Index reaches the value Sca = 1, in analogy to the Mach Number. Unsteady choking does not necessarily cause surface collapse. We show, that temporarily Speed Index values exceeding One may be achieved for a perfectly stable supercritical dynamic flow. As a supercritical criterion for the dynamic free surface stability we define a Dynamic Index D considering the local capillary pressure and the convective pressure, which is a function of the local velocity. The Dynamic Index is below One for stable flow while D = 1 indicates surface collapse. This studies result in a stability diagram, which defines the limits of flow dynamics and the maximum unsteady flow rate. It may serve as a road map for open capillary channel flow control.

  12. Effects of Mass Flow Rate on the Thermal-Flow Characteristics of Microwave CO2 Plasma.

    PubMed

    Hong, Chang-Ki; Na, Young-Ho; Uhm, Han-Sup; Kim, Youn-Jea

    2015-03-01

    In this study, the thermal-flow characteristics of atmospheric pressure microwave CO2 plasma were numerically investigated by simulation. The electric and gas flow fields in the reaction chamber with a microwave axial injection torch operated at 2.45 GHz were simulated. The microwave launcher had the standard rectangular waveguide WR340 geometry. The simulation was performed by using the COMSOL Multiphysics plasma model with various mass flow rates of CO2. The electric fields, temperature profiles and the density of electrons were graphically depicted for different CO2 inlet mass flow rates.

  13. Skeletal muscle contractions uncoupled from gravitational loading directly increase cortical bone blood flow rates in vivo.

    PubMed

    Caulkins, Carrie; Ebramzadeh, Edward; Winet, Howard

    2009-05-01

    The direct and indirect effects of muscle contraction on bone microcirculation and fluid flow are neither well documented nor explained. However, skeletal muscle contractions may affect the acquisition and maintenance of bone via stimulation of bone circulatory and interstitial fluid flow parameters. The purposes of this study were to assess the effects of transcutaneous electrical neuromuscular stimulation (TENS)-induced muscle contractions on cortical bone blood flow and bone mineral content, and to demonstrate that alterations in blood flow could occur independently of mechanical loading and systemic circulatory mechanisms. Bone chamber implants were used in a rabbit model to observe real-time blood flow rates and TENS-induced muscle contractions. Video recording of fluorescent microspheres injected into the blood circulation was used to calculate changes in cortical blood flow rates. TENS-induced repetitive muscle contractions uncoupled from mechanical loading instantaneously increased cortical microcirculatory flow, directly increased bone blood flow rates by 130%, and significantly increased bone mineral content over 7 weeks. Heart rates and blood pressure did not significantly increase due to TENS treatment. Our findings suggest that muscle contraction therapies have potential clinical applications for improving blood flow to cortical bone in the appendicular skeleton. Copyright 2008 Orthopaedic Research Society

  14. A methodology to reduce uncertainties in the high-flow portion of a rating curve

    USDA-ARS?s Scientific Manuscript database

    Flow monitoring at watershed scale relies on the establishment of a rating curve that describes the relationship between stage and flow and is developed from actual flow measurements at various stages. Measurement errors increase with out-of-bank flow conditions because of safety concerns and diffic...

  15. Collapse of Capillary Flows in Wedge-Shaped Channels

    NASA Astrophysics Data System (ADS)

    Klatte, Jörg; Dreyer, Michael E.

    The low gravity environment of the Bremen Drop Tower has been used to study free surface channel flows for different flow rates. In general the flow is dominated by inertia and surface-tension effects. The analysis of inertia-dominated free surface flows is of major interest because flow rate is limited due to a collapse of the free surface, which is one major design limit e.g. for propellant management devices in space. High-Resolution Experiments with convective dominated systems have been performed where the flow rate was increased up to the maximum value. In comparison to this we present unique three-dimensional computations to determine important characteristics of the flow, such as the free surface shape, the limiting flow rate and the developing flow profiles. The excellent agreement validates the capabilities of the numerical solver. Finally, the results of an para-metric study with a unique scaling which captures both inertia and viscous-dominated collapse behavior will be presented. The support for this research by the German Federal Ministry of Education and Research (BMBF) through the German Aerospace Center (DLR) under grant number 50WM0535/845 is gratefully acknowledged.

  16. The vortex as a clock

    NASA Astrophysics Data System (ADS)

    Breidenthal, Robert

    2003-11-01

    Using heuristic arguments, the fundamental effect of acceleration on dissipation in self-similar turbulence is explored. If the ratio of the next vortex rotation period to the last one is always constant, a flow is temporally self-similar. This implies that the vortex rotation period is a linear function of time. For ordinary, unforced turbulence, the period increases linearly in time. However, by imposing an external e-folding time scale on the flow that decreases linearly in time, the dissipation rate is changed from that of the corresponding unforced flow. The dissipation rate depends on the time rate of change of the rotation period as well as the dimensions of the dynamic quantity controlling the flow. For almost all canonical laboratory flows, acceleration reduces the dissipation and entrainment rates. An example is the exponential jet, where the flame length increases by about 20conventional jet. An exception is Rayleigh-Taylor flow, where acceleration increases the dissipation rate.

  17. Effects of milk flow on the physiological and behavioural responses to feeding in an infant with hypoplastic left heart syndrome.

    PubMed

    Pados, Britt F; Thoyre, Suzanne M; Estrem, Hayley H; Park, Jinhee; Knafl, George J; Nix, Brant

    2017-01-01

    Infants with hypoplastic left heart syndrome often experience difficulty with oral feeding, which contributes to growth failure, morbidity, and mortality. In response to feeding difficulty, clinicians often change the bottle nipple, and thus milk flow rate. Slow-flow nipples have been found to reduce the stress of feeding in other fragile infants, but no research has evaluated the responses of infants with hypoplastic left heart syndrome to alterations in milk flow. The purpose of this study was to evaluate the physiological and behavioural responses of an infant with hypoplastic left heart syndrome to bottle feeding with either a slow-flow (Dr. Brown's Preemie) or a standard-flow (Dr. Brown's Level 2) nipple. A single infant was studied for three feedings: two slow-flow and one standard-flow. Oral feeding, whether with a slow-flow or a standard-flow nipple, was distressing for this infant. During slow-flow feeding, she experienced more coughing events, whereas during standard-flow she experienced more gagging. Disengagement and compelling disorganisation were most common during feeding 3, that is slow-flow, which occurred 2 days after surgical placement of a gastrostomy tube. Clinically significant changes in heart rate, oxygen saturation, and respiratory rate were seen during all feedings. Heart rate was higher during standard-flow and respiratory rate was higher during slow-flow. Further research is needed to examine the responses of infants with hypoplastic left heart syndrome to oral feeding and to identify strategies that will support these fragile infants as they learn to feed. Future research should evaluate an even slower-flow nipple along with additional supportive feeding strategies.

  18. Liquid Jet Cavitation via Molecular Dynamics

    NASA Astrophysics Data System (ADS)

    Ashurst, W. T.

    1997-11-01

    A two-dimensional molecular dynamics simulation of a liquid jet is used to investigate cavitation in a diesel-like fuel injector. A channel with a length four times its width has been examined at various system sizes (widths of 20 to 160 σ, where σ is the zero energy location in the Lennard-Jones potential). The wall boundary condition is Maxwell's diffuse reflection, similar to the work by Sun & Ebner (Phys. Rev A 46, 4813, 1992). Currently, the jet exhausts into a vacuum, but a second, low density gas will be incorporated to represent the compressed air in a diesel chamber. Four different flow rates are examined. With ρ U equal to √mɛ/σ^2 (the largest flow rate) the static pressure decreases by a factor of twenty between the channel entrance and exit. The largest flow rate has a parabolic velocity profile with almost constant density across the channel. The smallest flow rate has the same velocity profile but the density exhibits a large variation, with the minimum value in the channel center. Thus, the product ρ U is nearly constant across the channel at this flow rate. The discharge coefficient CD has a small variation with flow rate, but the velocity coefficient CV varies with the amount of two-phase fluid within the channel. The ratio of CV to CD varies from 1.3 (largest flow rate) to 2.0 (the smallest flow rate, which is one-eighth of the largest).

  19. A Physical Model Study of Two-Phase Gas-Liquid Flows in a Ladle Shroud

    NASA Astrophysics Data System (ADS)

    Singh, Prince K.; Mazumdar, Dipak

    2018-06-01

    Argon-steel flows inside a ladle shroud during teeming from a ladle to a tundish have been modelled physically. To this end, full-scale Perspex models of bloom as well as slab casting shrouds (BCS and SCS), operating with air and water, have been applied. Both open to air as well as immersed conditions were investigated with and without gas injection. Flows inside a ladle shroud under open to air and immersed conditions were found to be substantially different with a strong function of gas and liquid flow rates, collector nozzle and shroud diameters. Depending on the volumetric gas injection rate relative to liquid flow rate, different flow regimes have been observed in an immersed shroud [ i.e., 0 < ( ds/L_{s} ) ≤ 0.24 ]. At extremely low gas flow rates, [ i.e., ( Qg/Q_{L} ) ≤ 0.02 ], injected gas is completely entrained as bubbles by the down-flowing liquid resulting in a bubbly two-phase flow over the entire length of a shroud. However, with an increasing gas flow rate, two distinctly different regions start to develop within the shroud body: a free liquid jet in the upper part and a gas-liquid mixing zone below. The length of the free jet increases with an increasing gas flow rate and at significantly higher gas to liquid flow rates [ viz., ( Qg/Q_{L} )_{BCS} ≥ 0.42 ] and [ viz., ( Qg/Q_{L} )_{SCS} ≥ 0.30 ] , and the free jet is found to prevail over the entire length of the shroud. Within the range of conditions studied, it is observed that the free jet length or the line of demarcation between the jetting and two-phase mixing zone depends on gas and liquid flow rates and is specific to a particular shroud-collector nozzle system. Physical model results further indicate that a sufficiently large free jet length ( shroud length) tends to create a high pressure region inside a shroud and prevent ingression of air. Possible implications of the present findings with reference to industrial teeming practices are also discussed in the text.

  20. Flow Rates Measurement and Uncertainty Analysis in Multiple-Zone Water-Injection Wells from Fluid Temperature Profiles

    PubMed Central

    Reges, José E. O.; Salazar, A. O.; Maitelli, Carla W. S. P.; Carvalho, Lucas G.; Britto, Ursula J. B.

    2016-01-01

    This work is a contribution to the development of flow sensors in the oil and gas industry. It presents a methodology to measure the flow rates into multiple-zone water-injection wells from fluid temperature profiles and estimate the measurement uncertainty. First, a method to iteratively calculate the zonal flow rates using the Ramey (exponential) model was described. Next, this model was linearized to perform an uncertainty analysis. Then, a computer program to calculate the injected flow rates from experimental temperature profiles was developed. In the experimental part, a fluid temperature profile from a dual-zone water-injection well located in the Northeast Brazilian region was collected. Thus, calculated and measured flow rates were compared. The results proved that linearization error is negligible for practical purposes and the relative uncertainty increases as the flow rate decreases. The calculated values from both the Ramey and linear models were very close to the measured flow rates, presenting a difference of only 4.58 m³/d and 2.38 m³/d, respectively. Finally, the measurement uncertainties from the Ramey and linear models were equal to 1.22% and 1.40% (for injection zone 1); 10.47% and 9.88% (for injection zone 2). Therefore, the methodology was successfully validated and all objectives of this work were achieved. PMID:27420068

  1. Experimental analysis of flow structure in contra-rotating axial flow pump designed with different rotational speed concept

    NASA Astrophysics Data System (ADS)

    Cao, Linlin; Watanabe, Satoshi; Imanishi, Toshiki; Yoshimura, Hiroaki; Furukawa, Akinori

    2013-08-01

    As a high specific speed pump, the contra-rotating axial flow pump distinguishes itself in a rear rotor rotating in the opposite direction of the front rotor, which remarkably contributes to the energy conversion, the reduction of the pump size, better hydraulic and cavitation performances. However, with two rotors rotating reversely, the significant interaction between blade rows was observed in our prototype contra-rotating rotors, which highly affected the pump performance compared with the conventional axial flow pumps. Consequently, a new type of rear rotor was designed by the rotational speed optimization methodology with some additional considerations, aiming at better cavitation performance, the reduction of blade rows interaction and the secondary flow suppression. The new rear rotor showed a satisfactory performance at the design flow rate but an unfavorable positive slope of the head — flow rate curve in the partial flow rate range less than 40% of the design flow rate, which should be avoided for the reliability of pump-pipe systems. In the present research, to understand the internal flow field of new rear rotor and its relation to the performances at the partial flow rates, the velocity distributions at the inlets and outlets of the rotors are firstly investigated. Then, the boundary layer flows on rotor surfaces, which clearly reflect the secondary flow inside the rotors, are analyzed through the limiting streamline observations using the multi-color oil-film method. Finally, the unsteady numerical simulations are carried out to understand the complicated internal flow structures in the rotors.

  2. Short range structure of 0.35Sb2O3-0.65(Li2O-P2O5) glass: A neutron diffraction study

    NASA Astrophysics Data System (ADS)

    Shinde, A. B.; Krishna, P. S. R.

    2018-04-01

    Neutron diffraction studies on Li2O-P2O5 and 0.35Sb2O3-0.65(Li2O-P2O5) glass are performed up to a Qmax of 15 Å-1 on the High-Q diffractometer, Dhruva. MCGR method is used to find pair correlation functions (g(r)) functions from experimentally obtained S(Q). We found that the Li-O and first Sb-O correlations to be around 2.04 Å & 2.15 Å. The O-O correlation from Phosphate & Antimony networks are found to be around 2.7 Å. The short range order of Sb is similar to its crystalline polymorph of valentinite instead of senarmonite. The short range order and network connectivity in this glass implies a structure composed of chains of corner sharing SbO3 pyramidal units connected to PO4 tetrahedra while Li acts as a modifier.

  3. Bio-removal of Nickel ions by Sporosarcina pasteurii and Bacillus megaterium, A Comparative Study

    NASA Astrophysics Data System (ADS)

    Gheethi, AA; Efaq, AN; Mohamed, RM; Abdel-Monem, MO; Halid Abdullah, Abd; Hashim, M. Amir

    2017-08-01

    The aim of this work was to study the potential of Sporosarcina pasteurii 586S and Bacillus megaterium 1295S isolated from sewage treatment plants (STPs) in removing of nickel ions from the aqueous solution. The bacterial cells were used as living and dead cell biomass. The efficiency of bio-removal process was investigated as a response for nickel and biomass concentrations, time, pH and temperature. The bio-removal capacity (Qmax) of both strains were compared. The highest bio-removal percentage was recorded by dead cells in comparison to living cells. Dead cell biomass of B. megaterium 1295S exhibited higher efficiency for bio-removing of Ni2+ than S. pasteurii 586S at196.4 and 200.2 mg Ni2+ g-1, respectively. It can be concluded that both bacterial strains have high potential to be applied in the biotechnology for removing of Ni2+ ions, however, dead cells of B. megaterium 1295S is the most potent.

  4. Adsorption of Ni(II) onto Chemically Modified Spent Grated Coconut (Cocos Nucifera)

    NASA Astrophysics Data System (ADS)

    Hamzah, F. I.; Khalid, K.; Hanafiah, M. A. K. M.

    2017-06-01

    A new adsorbent of plant waste origin from coconut processing food factory was explored for removing Ni(II) from aqueous solutions. Several parameters such as pH, dosage, concentration and contact time were studied to obtain optimum conditions for treatment of Ni(II) contaminated wastewater. Spent grated coconut (Cocos nucifera) treated with sulfuric acid (SSGC) showed good adsorption capacity for Ni(II) ion. The amount adsorbed was affected by solution pH with the highest value achieved at pH 5. Other optimum conditions found were; dosage of 0.02 g, and 60 min of equilibrium time. Ni(II) adsorption obeyed the pseudo-second order kinetic model which suggested that chemisorption mechanism occurred in the adsorption process. The equilibrium data presented a better fitting to the Langmuir isotherm model, an indication that monolayer adsorption occurred onto a homogeneous surface. The maximum adsorption capacity, qmax was 97.09 mg g-1, thus SSGC can be classified as good and comparable with other plant waste adsorbents.

  5. Adsorption of crude and engine oils from water using raw rice husk.

    PubMed

    Razavi, Zahra; Mirghaffari, Nourollah; Rezaei, Behzad

    2014-01-01

    The raw rice husk (RRH) was used as a low cost adsorbent to remove three oil compounds with different viscosities (crude oil, engine oil and spent engine oil) from an aqueous environment. Some of the sorbent specifications were characterized using a CHNSO analyzer, Fourier transform infrared, scanning electron microscope and inductively coupled plasma spectroscopy. With decreasing RRH particles size, the oil adsorption percentage was reduced for crude, spent and engine oils from 50 to 30%, 65 to 20% and 70 to 0.01%, respectively. This was probably due to damage of the microcavities. The removal percentage by sorbent at optimized conditions was 88, 80 and 55% for engine, spent and crude oils, respectively, corresponding to their descending viscosity. The adsorption of crude and spent oils on rice husk followed the Freundlich isotherm model, while the adsorption of engine oil was fitted by the Langmuir model. The maximum adsorption capacity (qmax), calculated from the Langmuir model for the adsorption of engine oil on RRH, was 1,250 mg/g.

  6. Efficient removal of malachite green dye using biodegradable graft copolymer derived from amylopectin and poly(acrylic acid).

    PubMed

    Sarkar, Amit Kumar; Pal, Aniruddha; Ghorai, Soumitra; Mandre, N R; Pal, Sagar

    2014-10-13

    This article reports on the application of a high performance biodegradable adsorbent based on amylopectin and poly(acrylic acid) (AP-g-PAA) for removal of toxic malachite green dye (MG) from aqueous solution. The graft copolymer has been synthesized and characterized using various techniques including FTIR, GPC, SEM and XRD analyses. Biodegradation study suggests that the co-polymer is biodegradable in nature. The adsorbent shows excellent potential (Qmax, 352.11 mg g(-1); 99.05% of MG has been removed within 30 min) for removal of MG from aqueous solution. It has been observed that point to zero charge (pzc) of graft copolymer plays significant role in adsorption efficacy. The adsorption kinetics and isotherm follow pseudo-second order and Langmuir isotherm models, respectively. Thermodynamics parameters suggest that the process of dye uptake is spontaneous. Finally desorption study shows excellent regeneration efficiency of adsorbent. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Modified madigan prostatectomy: a procedure preserved prostatic urethra intact.

    PubMed

    Lu, Jun; Ye, Zhangqun; Hu, Weilie

    2005-01-01

    A total of 92 patients with benign prostatic hyperplasia (BPH) were subjected to modified Madigan prostatectomy (MPC) for a much satisfactory effect in open prostatectomy surgery. Exposing anterior prostatic urethra near the bladder neck and conjunct cystotomy modified the MPC procedure. This modified procedure preserved prostatic urethra intact and could also deal with intracystic lesions at the same time. The intact of prostatic urethra was kept completely or largely in 86 cases. The amount of blood loss during modified procedure was less. The mean operative time was 105 min. Seventy patients had been followed up for 3-24 months. The postoperative average Qmax was 19. 2 ml/s. The cystourethrography revealed that the urethra and bladder neck were intact in 10 patients postoperatively. Furthermore, the prostatic urethra was obviously wider after modified MPC. The modified MPC can reduce the occurrence of urethra injury and enlarge the MPC indications. The modified technique is easy to perform with less complications and much satisfactory clinical result.

  8. Removal of uranium (VI) from aqueous systems by nanoscale zero-valent iron particles suspended in carboxy-methyl cellulose

    NASA Astrophysics Data System (ADS)

    Popescu (Hoştuc), Ioana-Carmen; Filip, Petru; Humelnicu, Doina; Humelnicu, Ionel; Scott, Thomas Bligh; Crane, Richard Andrew

    2013-11-01

    Carboxy-methyl-cellulose (CMC), a common "delivery vehicle" for the subsurface deployment of iron nanoparticles (INP) has been tested in the current work for the removal of aqueous uranium from synthetic water samples. A comparison of the removal of aqueous uranium from solutions using carboxy-methyl-cellulose with and without iron nanoparticles (CMC-INP and CMC, respectively) was tested over a 48 h reaction period. Analysis of liquid samples using spectrophotometry determined a maximum sorption capacity of uranium, Qmax, of 185.18 mg/g and 322.58 mg/g for CMC and CMC-INP respectively, providing strong evidence of an independent aqueous uranium removal ability exhibited by CMC. The results point out that CMC provides an additional capacity for aqueous uranium removal. Further tests are required to determine whether similar behaviour will be observed for other aqueous contaminant species and if the presence of CMC within a INP slurry inhibits or aids the reactivity, reductive capacity and affinity of INP for aqueous contaminant removal.

  9. Nickel adsorption by magnetic alginate microcapsules containing an extractant.

    PubMed

    Ngomsik, Audrey-Flore; Bee, Agnès; Siaugue, Jean-Michel; Cabuil, Valérie; Cote, Gérard

    2006-05-01

    The adsorption of heavy metals on biomaterials was investigated by studying the potential of alginate microcapsules containing an extractant (Cyanex 272) and magnetic nanoparticles (gamma-Fe2O3) for the adsorption of nickel (II) from aqueous solutions. A two-stage kinetics behaviour was observed with 70% of the maximum sorption capacity achieved within 8 h. An increase in nickel removal with increase in pH occurred, the maximum uptake capacity being around 0.42 mmol g-1 at pH 8. The adsorption isotherm (pH about 5.3) was obtained in a wide range of initial nickel concentrations; the experimental data were fitted by a Langmuir model and the qmax value was estimated to be 0.52 mmol g-1. Moreover, including magnetic particles in the microcapsules allowed easy isolation of the beads from the aqueous solutions after the sorption process. Magnetic microcapsules are then suitable for the development of efficient biosorbents for removal and recovery of heavy metals from wastewater using magnetic separation.

  10. Flow range enhancement by secondary flow effect in low solidity circular cascade diffusers

    NASA Astrophysics Data System (ADS)

    Sakaguchi, Daisaku; Tun, Min Thaw; Mizokoshi, Kanata; Kishikawa, Daiki

    2014-08-01

    High-pressure ratio and wide operating range are highly required for compressors and blowers. The technical issue of the design is achievement of suppression of flow separation at small flow rate without deteriorating the efficiency at design flow rate. A numerical simulation is very effective in design procedure, however, cost of the numerical simulation is generally high during the practical design process, and it is difficult to confirm the optimal design which is combined with many parameters. A multi-objective optimization technique is the idea that has been proposed for solving the problem in practical design process. In this study, a Low Solidity circular cascade Diffuser (LSD) in a centrifugal blower is successfully designed by means of multi-objective optimization technique. An optimization code with a meta-model assisted evolutionary algorithm is used with a commercial CFD code ANSYS-CFX. The optimization is aiming at improving the static pressure coefficient at design point and at low flow rate condition while constraining the slope of the lift coefficient curve. Moreover, a small tip clearance of the LSD blade was applied in order to activate and to stabilize the secondary flow effect at small flow rate condition. The optimized LSD blade has an extended operating range of 114 % towards smaller flow rate as compared to the baseline design without deteriorating the diffuser pressure recovery at design point. The diffuser pressure rise and operating flow range of the optimized LSD blade are experimentally verified by overall performance test. The detailed flow in the diffuser is also confirmed by means of a Particle Image Velocimeter. Secondary flow is clearly captured by PIV and it spreads to the whole area of LSD blade pitch. It is found that the optimized LSD blade shows good improvement of the blade loading in the whole operating range, while at small flow rate the flow separation on the LSD blade has been successfully suppressed by the secondary flow effect.

  11. 40 CFR 53.53 - Test for flow rate accuracy, regulation, measurement accuracy, and cut-off.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... pressures and temperatures used in the tests and shall be checked at zero and at least one flow rate within...: Equation 5 ER18jy97.067 (ii) To successfully pass the flow rate CV measurement accuracy test, the absolute...

  12. 40 CFR 53.53 - Test for flow rate accuracy, regulation, measurement accuracy, and cut-off.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... pressures and temperatures used in the tests and shall be checked at zero and at least one flow rate within...: Equation 5 ER18jy97.067 (ii) To successfully pass the flow rate CV measurement accuracy test, the absolute...

  13. 40 CFR 53.53 - Test for flow rate accuracy, regulation, measurement accuracy, and cut-off.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... pressures and temperatures used in the tests and shall be checked at zero and at least one flow rate within...: Equation 5 ER18jy97.067 (ii) To successfully pass the flow rate CV measurement accuracy test, the absolute...

  14. 40 CFR 53.53 - Test for flow rate accuracy, regulation, measurement accuracy, and cut-off.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... pressures and temperatures used in the tests and shall be checked at zero and at least one flow rate within...: Equation 5 ER18jy97.067 (ii) To successfully pass the flow rate CV measurement accuracy test, the absolute...

  15. Body position and activity, but not heart rate, affect pump flows in patients with continuous-flow left ventricular assist devices.

    PubMed

    Muthiah, Kavitha; Gupta, Sunil; Otton, James; Robson, Desiree; Walker, Robyn; Tay, Andre; Macdonald, Peter; Keogh, Anne; Kotlyar, Eugene; Granger, Emily; Dhital, Kumud; Spratt, Phillip; Jansz, Paul; Hayward, Christopher S

    2014-08-01

    The aim of this study was to determine the contribution of pre-load and heart rate to pump flow in patients implanted with continuous-flow left ventricular assist devices (cfLVADs). Although it is known that cfLVAD pump flow increases with exercise, it is unclear if this increment is driven by increased heart rate, augmented intrinsic ventricular contraction, or enhanced venous return. Two studies were performed in patients implanted with the HeartWare HVAD. In 11 patients, paced heart rate was increased to approximately 40 beats/min above baseline and then down to approximately 30 beats/min below baseline pacing rate (in pacemaker-dependent patients). Ten patients underwent tilt-table testing at 30°, 60°, and 80° passive head-up tilt for 3 min and then for a further 3 min after ankle flexion exercise. This regimen was repeated at 20° passive head-down tilt. Pump parameters, noninvasive hemodynamics, and 2-dimensional echocardiographic measures were recorded. Heart rate alteration by pacing did not affect LVAD flows or LV dimensions. LVAD pump flow decreased from baseline 4.9 ± 0.6 l/min to approximately 4.5 ± 0.5 l/min at each level of head-up tilt (p < 0.0001 analysis of variance). With active ankle flexion, LVAD flow returned to baseline. There was no significant change in flow with a 20° head-down tilt with or without ankle flexion exercise. There were no suction events. Centrifugal cfLVAD flows are not significantly affected by changes in heart rate, but they change significantly with body position and passive filling. Previously demonstrated exercise-induced changes in pump flows may be related to altered loading conditions, rather than changes in heart rate. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  16. Bedload Rating and Flow Competence Curves Vary With Watershed and Bed Material Parameters

    NASA Astrophysics Data System (ADS)

    Bunte, K.; Abt, S. R.

    2003-12-01

    Bedload transport rating curves and flow competence curves (largest bedload size for specified flow) are usually not known for streams unless a large number of bedload samples has been collected and analyzed. However, this information is necessary for assessing instream flow needs and stream responses to watershed effects. This study therefore analyzed whether bedload transport rating and flow competence curves were related to stream parameters. Bedload transport rating curves and flow competence curves were obtained from extensive bedload sampling in six gravel- and cobble-bed mountain streams. Samples were collected using bedload traps and a large net sampler, both of which provide steep and relatively well-defined bedload rating and flow competence curves due to a long sampling duration, a large sampler opening and a large sampler capacity. The sampled streams have snowmelt regimes, steep (1-9%) gradients, and watersheds that are mainly forested and relatively undisturbed with basin area sizes of 8 to 105 km2. The channels are slightly incised and can contain flows of more than 1.5 times bankfull with little overbank flow. Exponents of bedload rating and flow competence curves obtained from these measurements were found to systematically increase with basin area size and decrease with the degree of channel armoring. By contrast, coefficients of bedload rating and flow competence curves decreased with basin size and increased with armoring. All of these relationships were well-defined (0.86 < r2 < 0.99). Data sets from other studies in coarse-bedded streams fit the indicated trend if the sampling device used allows measuring bedload transport rates over a wide range and if bedload supply is somewhat low. The existence of a general positive trend between bedload rating curve exponents and basin area, and a negative trend between coefficients and basin area, is confirmed by a large data set of bedload rating curves obtained from Helley-Smith samples. However, in this case, the trends only become visible as basin area sizes span a wide range (1 - 10,000 km2). The well-defined relationships obtained from the bedload trap and the large net sampler suggest that exponents and coefficients of bedload transport rating curves (and flow competence curves) are predictable from an easily obtainable parameter such as basin size. However, the relationships of bedload rating curve exponents and coefficients with basin size and armoring appear to be influenced by the sampling device used and the watershed sediment production.

  17. Investigation of polar organic chemical integrative sampler (POCIS) flow rate dependence for munition constituents in underwater environments.

    PubMed

    Lotufo, Guilherme R; George, Robert D; Belden, Jason B; Woodley, Christa M; Smith, David L; Rosen, Gunther

    2018-02-24

    Munition constituents (MC) are present in aquatic environments throughout the world. Potential for fluctuating release with low residence times may cause concentrations of MC to vary widely over time at contaminated sites. Recently, polar organic chemical integrative samplers (POCIS) have been demonstrated to be valuable tools for the environmental exposure assessment of MC in water. Flow rate is known to influence sampling by POCIS. Because POCIS sampling rates (R s ) for MC have only been determined under quasi-static conditions, the present study evaluated the uptake of 2,4,6-trinitrotoluene (TNT), RDX (hexahydro-1,3,5-trinitro-1,3,5-triazine), and 2,4- and 2,6-dinitrotoluenes (DNT), by POCIS in a controlled water flume at 7, 15, and 30 cm/s in 10-day experiments using samplers both within and without a protective cage. Sampling rate increased with flow rate for all MC investigated, but flow rate had the strongest impact on TNT and the weakest impact on RDX. For uncaged POCIS, mean R s for 30 cm/s was significantly higher than that for 7 cm by 2.7, 1.9, 1.9, and 1.3 folds for TNT, 2,4-DNT, 2,6-DNT, and RDX, respectively. For all MC except RDX, mean R s for caged POCIS at 7 cm/s were significantly lower than for uncaged samplers and similar to those measured at quasi-static condition, but except for 2,6-DNT, no caging effect was measured at the highest flow rate, indicating that the impact of caging on R s is flow rate-dependent. When flow rates are known, flow rate-specific R s should be used for generating POCIS-derived time-averaged concentrations of MC at contaminated sites.

  18. Very high pressure liquid chromatography using core-shell particles: quantitative analysis of fast gradient separations without post-run times.

    PubMed

    Stankovich, Joseph J; Gritti, Fabrice; Stevenson, Paul G; Beaver, Lois A; Guiochon, Georges

    2014-01-17

    Five methods for controlling the mobile phase flow rate for gradient elution analyses using very high pressure liquid chromatography (VHPLC) were tested to determine thermal stability of the column during rapid gradient separations. To obtain rapid separations, instruments are operated at high flow rates and high inlet pressure leading to uneven thermal effects across columns and additional time needed to restore thermal equilibrium between successive analyses. The purpose of this study is to investigate means to minimize thermal instability and obtain reliable results by measuring the reproducibility of the results of six replicate gradient separations of a nine component RPLC standard mixture under various experimental conditions with no post-run times. Gradient separations under different conditions were performed: constant flow rates, two sets of constant pressure operation, programmed flow constant pressure operation, and conditions which theoretically should yield a constant net heat loss at the column's wall. The results show that using constant flow rates, programmed flow constant pressures, and constant heat loss at the column's wall all provide reproducible separations. However, performing separations using a high constant pressure with programmed flow reduces the analysis time by 16% compared to constant flow rate methods. For the constant flow rate, programmed flow constant pressure, and constant wall heat experiments no equilibration time (post-run time) was required to obtain highly reproducible data. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Effects of variations in flow characteristics through W.P. Franklin Lock and Dam on downstream water quality in the Caloosahatchee River Estuary and in McIntyre Creek in the J.N. “Ding” Darling National Wildlife Refuge, southern Florida, 2010–13

    USGS Publications Warehouse

    Booth, Amanda C.; Soderqvist, Lars E.; Knight, Travis M.

    2016-05-17

    The U.S. Geological Survey studied water-quality trends at the mouth of McIntyre Creek, an entry point to the J.N. “Ding” Darling National Wildlife Refuge, to investigate correlations between flow rates and volumes through the W.P. Franklin Lock and Dam and water-quality constituents inside the refuge from March 2010 to December 2013. Outflow from Lake Okeechobee, and flows from Franklin Lock, tributaries to the Caloosahatchee River Estuary, and the Cape Coral canal system were examined to determine the sources and quantity of water to the study area. Salinity, temperature, dissolved-oxygen concentration, pH, turbidity, and chromophoric dissolved organic matter fluorescence (FDOM) were measured during moving-boat surveys and at a fixed location in McIntyre Creek. Chlorophyll fluorescence was also recorded in McIntyre Creek. Water-quality surveys were completed on 20 dates between 2011 and 2014 using moving-boat surveys.Franklin Lock contributed the majority of flow to the Caloosahatchee River. Between 2010 and 2013, the monthly mean flow rate at Franklin Lock ranged from 29 cubic feet per second in May 2011 to 10,650 cubic feet per second in August 2013. Instantaneous near-surface salinity in McIntyre Creek ranged from 12.9 parts per thousand on September 26, 2013, to 37.9 parts per thousand on June 27, 2011. Salinity in McIntyre Creek decreased with increasing flow rate through Franklin Lock. Flow rates through Franklin Lock explained 61 percent of the variation in salinity in McIntyre Creek. Salinity data from moving-boat surveys also indicate that an increase in flow rate at Franklin Lock decreases salinity in the Caloosahatchee River Estuary, and a reduction or elimination in flow increases salinity. The FDOM in McIntyre Creek was positively correlated with flow at Franklin Lock, and 54 percent of the variation in FDOM can be attributed to the flow rate through Franklin Lock. Data from moving-boat surveys indicate that FDOM increases when flow volume from Franklin Lock increases. The highest FDOM recorded during a survey was at Billy’s Creek. Chlorophyll fluorescence was positively correlated with flow at Franklin Lock, with 23 percent of the variation explained by the flow rate at Franklin Lock. An increase in flow rate at Franklin Lock resulted in a decrease in pH (21 percent of variation explained by flow rates). Data from the pH surveys indicate an increase in pH with distance from Franklin Lock. Turbidity and dissolved oxygen near the surface in McIntyre Creek were not correlated with flow rate at Franklin Lock. Moving-boat surveys did not document a change in turbidity or dissolved oxygen with a change in distance from the Franklin Lock. Correlations between Franklin Lock flow rate and water quality in McIntyre Creek indicate that releases at Franklin Lock affect water quality in the Caloosahatchee River Estuary and Ding Darling Refuge.

  20. Quantifying Hydrate Formation in Gas-rich Environments Using the Method of Characteristics

    NASA Astrophysics Data System (ADS)

    You, K.; Flemings, P. B.; DiCarlo, D. A.

    2015-12-01

    Methane hydrates hold a vast amount of methane globally, and have huge energy potential. Methane hydrates in gas-rich environments are the most promising production targets. We develop a one-dimensional analytical solution based on the method of characteristics to explore hydrate formation in such environments (Figure 1). Our solution shows that hydrate saturation is constant with time and space in a homogeneous system. Hydrate saturation is controlled by the initial thermodynamic condition of the system, and changed by the gas fractional flow. Hydrate saturation increases with the initial distance from the hydrate phase boundary. Different gas fractional flows behind the hydrate solidification front lead to different gas saturations at the hydrate solidification front. The higher the gas saturation at the front, the less the volume available to be filled by hydrate, and hence the lower the hydrate saturation. The gas fractional flow depends on the relative permeability curves, and the forces that drive the flow. Viscous forces (the drive for flow induced from liquid pressure gradient) dominate the flow, and hydrate saturation is independent on the gas supply rates and the flow directions at high gas supply rates. Hydrate saturation can be estimated as one minus the ratio of the initial to equilibrium salinity. Gravity forces (the drive for flow induced from the gravity) dominate the flow, and hydrate saturation depends on the flow rates and the flow directions at low gas supply rates. Hydrate saturation is highest for upward flow, and lowest for downward flow. Hydrate saturation decreases with the flow rate for upward flow, and increases with the flow rate for downward flow. This analytical solution illuminates how hydrate is formed by gas (methane, CO2, ethane, propane) flowing into brine-saturated sediments at both the laboratory and geological scales (Figure 1). It provides an approach to generalize the understanding of hydrate solidification in gas-rich environments, although complicated numerical models have been developed previously. Examples of gas expulsion into hydrate stability zones and the associated hydrate formation in both laboratory and geological scales, and CO2 sequestration into CO2-hydrates near the seafloor and under the permafrost will be presented.

  1. Dynamic Characteristics of The DSI-Type Constant-Flow Valves

    NASA Astrophysics Data System (ADS)

    Kang, Yuan; Hu, Sheng-Yan; Chou, Hsien-Chin; Lee, Hsing-Han

    Constant flow valves have been presented in industrial applications or academic studies, which compensate recess pressures of a hydrostatic bearing to resist load fluctuating. The flow rate of constant-flow valves can be constant in spite of the pressure changes in recesses, however the design parameters must be specified. This paper analyzes the dynamic responses of DSI-type constant-flow valves that is designed as double pistons on both ends of a spool with single feedback of working pressure and regulating restriction at inlet. In this study the static analysis presents the specific relationships among design parameters for constant flow rate and the dynamic analyses give the variations around the constant flow rate as the working pressure fluctuates.

  2. Measurement of cerebral blood flow rate and its relationship with brain function using optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Liu, Jian; Wang, Yi; Zhao, Yuqian; Dou, Shidan; Ma, Yushu; Ma, Zhenhe

    2016-03-01

    Activity of brain neurons will lead to changes in local blood flow rate (BFR). Thus, it is important to measure the local BFR of cerebral cortex on research of neuron activity in vivo, such as rehabilitation evaluation after stroke, etc. Currently, laser Doppler flowmetry is commonly used for blood flow measurement, however, relatively low resolution limits its application. Optical coherence tomography (OCT) is a powerful noninvasive 3D imaging modality with high temporal and spatial resolutions. Furthermore, OCT can provide flow distribution image by calculating Doppler frequency shift which makes it possible for blood flow rate measurement. In this paper, we applied OCT to measure the blood flow rate of the primary motor cortex in rats. The animal was immobilized and anesthetized with isoflurane, an incision was made along the sagittal suture, and bone was exposed. A skull window was opened on the primary motor cortex. Then, blood flow rate changes in the primary motor cortex were monitored by our homemade spectral domain OCT with a stimulation of the passive movement of the front legs. Finally, we established the relationship between blood flow rate and the test design. The aim is to demonstrate the potential of OCT in the evaluation of cerebral cortex function.

  3. A pilot study of change in cerebral activity during personality rating by questionnaire and personal computer.

    PubMed

    Sato, Emi; Matsuda, Kouhei

    2018-06-11

    The purpose of this study was to examine cerebral blood flow in the frontal cortex area during personality self-rating tasks. Our two hypotheses were (1) cerebral blood flow varies based on personality rating condition and (2) cerebral blood flow varies based on the personality traits. This experiment measured cerebral blood flow under 3 personal computer rating conditions and 2 questionnaire conditions. Comparing the rating conditions, the results of the t-test indicated that cerebral blood flow was higher in the questionnaire condition than it was in the personal computer condition. With respect to the Big Five, the result of the correlation coefficient, that is, cerebral blood flow during a personality rating task, changed according to the trait for agreeableness. The results of the analysis of the 5-cluster on individual differences indicated that certain personality traits were related to the factors that increased or decreased cerebral blood flow. An analysis of variance indicated that openness to experience and Behavioural Activation System-drive was significant given that participants with high intellectual curiosity were motivated in this experiment, thus, their cerebral blood flow may have increased. The significance of this experiment was that by employing certain performance measures we could examine differences in physical changes based on personality traits. © 2018 International Union of Psychological Science.

  4. Melt volume flow rate and melt flow rate of kenaf fibre reinforced Floreon/magnesium hydroxide biocomposites.

    PubMed

    Lee, C H; Sapuan, S M; Lee, J H; Hassan, M R

    2016-01-01

    A study of the melt volume flow rate (MVR) and the melt flow rate (MFR) of kenaf fibre (KF) reinforced Floreon (FLO) and magnesium hydroxide (MH) biocomposites under different temperatures (160-180 °C) and weight loadings (2.16, 5, 10 kg) is presented in this paper. FLO has the lowest values of MFR and MVR. The increment of the melt flow properties (MVR and MFR) has been found for KF or MH insertion due to the hydrolytic degradation of the polylactic acid in FLO. Deterioration of the entanglement density at high temperature, shear thinning and wall slip velocity were the possible causes for the higher melt flow properties. Increasing the KF loadings caused the higher melt flow properties while the higher MH contents created stronger bonding for higher macromolecular chain flow resistance, hence lower melt flow properties were recorded. However, the complicated melt flow behaviour of the KF reinforced FLO/MH biocomposites was found in this study. The high probability of KF-KF and KF-MH collisions was expected and there were more collisions for higher fibre and filler loading causing lower melt flow properties.

  5. Effect of groundwater flow on remediation of dissolved-phase VOC contamination using air sparging.

    PubMed

    Reddy, K R; Adams, J A

    2000-02-25

    This paper presents two-dimensional laboratory experiments performed to study how groundwater flow may affect the injected air zone of influence and remedial performance, and how injected air may alter subsurface groundwater flow and contaminant migration during in situ air sparging. Tests were performed by subjecting uniform sand profiles contaminated with dissolved-phase benzene to a hydraulic gradient and two different air flow rates. The results of the tests were compared to a test subjected to a similar air flow rate but a static groundwater condition. The test results revealed that the size and shape of the zone of influence were negligibly affected by groundwater flow, and as a result, similar rates of contaminant removal were realized within the zone of influence with and without groundwater flow. The air flow, however, reduced the hydraulic conductivity within the zone of influence, reducing groundwater flow and subsequent downgradient contaminant migration. The use of a higher air flow rate further reduced the hydraulic conductivity and decreased groundwater flow and contaminant migration. Overall, this study demonstrated that air sparging may be effectively implemented to intercept and treat a migrating contaminant plume.

  6. Comparative in vitro flow study of 3 different Ex-PRESS miniature glaucoma device models.

    PubMed

    Estermann, Stephan; Yuttitham, Kanokwan; Chen, Julie A; Lee, On-Tat; Stamper, Robert L

    2013-03-01

    To determine the flow characteristics of the 3 different models of the Ex-PRESS miniature glaucoma device in a controlled laboratory study. The 3 different Ex-PRESS models (P-50, R-50, and P-200; Optonol Ltd; now Alcon Lab) were tested using a gravity-driven flow test. Three samples of each of the 3 Ex-PRESS models were subjected to a constant gravitational force of fluid at 5 different pressure levels (5 to 25 mm Hg). Four measurements per sample were taken at each pressure level. The main outcome measure was flow rate (Q) (µL/min). Resistance (R) was calculated by dividing pressure (P) by the measured flow (Q). The flow rate was primarily pressure dependent. The P-200 model (internal diameter 200 µm) showed a statistically significant higher flow rate and lower resistance compared with both the P-50 and R-50 models (internal diameter 50 µm) (P<0.0001). The P-50 and R-50 models demonstrated similar flow rates (P=0.08) despite their difference in tube length (2.64 vs. 2.94 mm). The 3 models of the Ex-PRESS mini shunt behaved in vitro as simple flow resistors by creating a relatively constant resistance to flow. Tube diameter was the only parameter with significant impact on flow and resistance. All models demonstrated flow rates per unit of pressure much higher than the outflow facility of a healthy human eye.

  7. Relationship between xerostomia and salivary flow rates in HIV-infected individuals.

    PubMed

    Nittayananta, Wipawee; Chanowanna, Nilnara; Pruphetkaew, Nannapat; Nauntofte, Birgitte

    2013-08-01

    The aim of the present study was to determine the relationship between self-reported xerostomia and salivary flow rates among HIV-infected individuals. A cross-sectional study was performed on 173 individuals (81 HIV-infected individuals, mean age: 32 years, and 92 non-HIV controls, mean age: 30 years). Subjective complaints of dry mouth, based on a self-report of xerostomia questions, and dry mouth, based on a visual analogue scale (VAS), were recorded along with measurements of salivary flow rate of both unstimulated and wax-stimulated whole saliva. The relationship between subjective responses to the xerostomia questions, the VAS of dry mouth, and objective measurements of salivary flow rates were analyzed. Responses to the questions--Do you carry water or a saliva substitute? and Have you had taste disturbance?--were significantly different between HIV-infected and non-HIV individuals (P < 0.05). Individuals' responses to questions concerning dry mouth were significantly correlated with a low unstimulated salivary flow rate. A significant correlation between the VAS of dry mouth and salivary flow rates was observed (P = 0.023). Responses to self-reported xerostomia questions reflects low unstimulated salivary flow rates. Thus, questions concerning dry mouth might be useful tools to identify HIV-infected individuals with hyposalivation, especially at a resting stage. © 2013 Wiley Publishing Asia Pty Ltd.

  8. Relationship Between the Urine Flow Rate and Risk of Contrast-Induced Nephropathy After Emergent Percutaneous Coronary Intervention

    PubMed Central

    Liu, Yong; Lin, Lixia; Li, Yun; Li, Hualong; Wu, Deng-Xuan; Zhao, Jian-bin; Lian, Dan; Zhou, Yingling; Liu, Yuanhui; Ye, Piao; Ran, Peng; Duan, Chongyang; Chen, Shiqun; Chen, Pingyan; Xian, Ying; Chen, Jiyan; Tan, Ning

    2015-01-01

    Abstract A low urine flow rate is a marker of acute kidney injury. However, it is unclear whether a high urine flow rate is associated with a reduced risk of contrast-induced nephropathy (CIN) in high-risk patients. We conducted this study to evaluate the predictive value of the urine flow rate for the risk of CIN following emergent percutaneous coronary intervention (PCI). We prospectively examined 308 patients undergoing emergent PCI who provided consent. The predictive value of the 24-hour postprocedural urine flow rate, adjusted by weight (UR/W, mL/kg/h) and divided into quartiles, for the risk of CIN was assessed using multivariate logistic regression analysis. The cumulative incidence of CIN was 24.4%. In particular, CIN was observed in 29.5%, 19.5%, 16.7%, and 32.0% of cases in the UR/W quartile (Q)-1 (≤0.94 mL/kg/h), Q2 (0.94–1.30 mL/kg/h), Q3 (1.30–1.71 mL/kg/h), and Q4 (≥1.71 mL/kg/h), respectively. Moreover, in-hospital death was noted in 7.7%, 3.9%, 5.1%, and 5.3% of patients in Q1, Q2, Q3, and Q4, respectively. After adjusting for potential confounding predictors, multivariate analysis indicated that compared with the moderate urine flow rate quartiles (Q2 + Q3), a high urine flow rate (Q4) (odds ratio [OR], 2.69; 95% confidence interval [CI], 1.27–5.68; P = 0.010) and low urine flow rate (Q1) (OR, 2.23; 95% CI, 1.03–4.82; P = 0.041) were significantly associated with an increased risk of CIN. Moreover, a moderate urine flow rate (0.94–1.71 mL/kg/h) was significantly associated with a decreased risk of mortality. Our data suggest that higher and lower urine flow rates were significantly associated with an increased risk of CIN after emergent PCI, and a moderate urine flow rate (0.94–1.71 mL/kg/h) may be associated with a decreased risk of CIN with a good long-term prognosis after emergent PCI. PMID:26683946

  9. Relationship Between the Urine Flow Rate and Risk of Contrast-Induced Nephropathy After Emergent Percutaneous Coronary Intervention.

    PubMed

    Liu, Yong; Lin, Lixia; Li, Yun; Li, Hualong; Wu, Deng-Xuan; Zhao, Jian-bin; Lian, Dan; Zhou, Yingling; Liu, Yuanhui; Ye, Piao; Ran, Peng; Duan, Chongyang; Chen, Shiqun; Chen, Pingyan; Xian, Ying; Chen, Jiyan; Tan, Ning

    2015-12-01

    A low urine flow rate is a marker of acute kidney injury. However, it is unclear whether a high urine flow rate is associated with a reduced risk of contrast-induced nephropathy (CIN) in high-risk patients. We conducted this study to evaluate the predictive value of the urine flow rate for the risk of CIN following emergent percutaneous coronary intervention (PCI). We prospectively examined 308 patients undergoing emergent PCI who provided consent. The predictive value of the 24-hour postprocedural urine flow rate, adjusted by weight (UR/W, mL/kg/h) and divided into quartiles, for the risk of CIN was assessed using multivariate logistic regression analysis. The cumulative incidence of CIN was 24.4%. In particular, CIN was observed in 29.5%, 19.5%, 16.7%, and 32.0% of cases in the UR/W quartile (Q)-1 (≤0.94  mL/kg/h), Q2 (0.94-1.30  mL/kg/h), Q3 (1.30-1.71  mL/kg/h), and Q4 (≥1.71  mL/kg/h), respectively. Moreover, in-hospital death was noted in 7.7%, 3.9%, 5.1%, and 5.3% of patients in Q1, Q2, Q3, and Q4, respectively. After adjusting for potential confounding predictors, multivariate analysis indicated that compared with the moderate urine flow rate quartiles (Q2 + Q3), a high urine flow rate (Q4) (odds ratio [OR], 2.69; 95% confidence interval [CI], 1.27-5.68; P = 0.010) and low urine flow rate (Q1) (OR, 2.23; 95% CI, 1.03-4.82; P = 0.041) were significantly associated with an increased risk of CIN. Moreover, a moderate urine flow rate (0.94-1.71  mL/kg/h) was significantly associated with a decreased risk of mortality. Our data suggest that higher and lower urine flow rates were significantly associated with an increased risk of CIN after emergent PCI, and a moderate urine flow rate (0.94-1.71  mL/kg/h) may be associated with a decreased risk of CIN with a good long-term prognosis after emergent PCI.

  10. A methodology to reduce uncertainties in the high-flow portion of the rating curve for Goodwater Creek Watershed

    USDA-ARS?s Scientific Manuscript database

    Flow monitoring at watershed scale relies on the establishment of a rating curve that describes the relationship between stage and flow and is developed from actual flow measurements at various stages. Measurement errors increase with out-of-bank flow conditions because of safety concerns and diffic...

  11. Effect of the SiCl4 Flow Rate on SiBN Deposition Kinetics in SiCl4-BCl3-NH3-H2-Ar Environment

    PubMed Central

    Li, Jianping; Qin, Hailong; Liu, Yongsheng; Ye, Fang; Li, Zan; Cheng, Laifei; Zhang, Litong

    2017-01-01

    To improve the thermal and mechanical stability of SiCf/SiC or C/SiC composites with SiBN interphase, SiBN coating was deposited by low pressure chemical vapor deposition (LPCVD) using SiCl4-BCl3-NH3-H2-Ar gas system. The effect of the SiCl4 flow rate on deposition kinetics was investigated. Results show that deposition rate increases at first and then decreases with the increase of the SiCl4 flow rate. The surface of the coating is a uniform cauliflower-like structure at the SiCl4 flow rate of 10 mL/min and 20 mL/min. The surface is covered with small spherical particles when the flow rate is 30 mL/min. The coatings deposited at various SiCl4 flow rates are all X-ray amorphous and contain Si, B, N, and O elements. The main bonding states are B-N, Si-N, and N-O. B element and B-N bonding decrease with the increase of SiCl4 flow rate, while Si element and Si-N bonding increase. The main deposition mechanism refers to two parallel reactions of BCl3+NH3 and SiCl4+NH3. The deposition process is mainly controlled by the reaction of BCl3+NH3. PMID:28772986

  12. Scaling laws in granular flow and pedestrian flow

    NASA Astrophysics Data System (ADS)

    Chen, Shumiao; Alonso-Marroquin, Fernando; Busch, Jonathan; Hidalgo, Raúl Cruz; Sathianandan, Charmila; Ramírez-Gómez, Álvaro; Mora, Peter

    2013-06-01

    We use particle-based simulations to examine the flow of particles through an exit. Simulations involve both gravity-driven particles (representing granular material) and velocity-driven particles (mimicking pedestrian dynamics). Contact forces between particles include elastic, viscous, and frictional forces; and simulations use bunker geometry. Power laws are observed in the relation between flow rate and exit width. Simulations of granular flow showed that the power law has little dependence on the coefficient of friction. Polydisperse granular systems produced higher flow rates than those produced by monodisperse ones. We extend the particle model to include the main features of pedestrian dynamics: thoracic shape, shoulder rotation, and desired velocity oriented towards the exit. Higher desired velocity resulted in higher flow rate. Granular simulations always give higher flow rate than pedestrian simulations, despite the values of aspect ratio of the particles. In terms of force distribution, pedestrians and granulates share similar properties with the non-democratic distribution of forces that poses high risks of injuries in a bottleneck situation.

  13. Surface-acoustic-wave (SAW) flow sensor

    NASA Astrophysics Data System (ADS)

    Joshi, Shrinivas G.

    1991-03-01

    The use of a surface-acoustic-wave (SAW) device to measure the rate of gas flow is described. A SAW oscillator heated to a suitable temperature above ambient is placed in the path of a flowing gas. Convective cooling caused by the gas flow results in a change in the oscillator frequency. A 73-MHz oscillator fabricated on 128 deg rotated Y-cut lithium niobate substrate and heated to 55 C above ambient shows a frequency variation greater than 142 kHz for flow-rate variation from 0 to 1000 cu cm/min. The output of the sensor can be calibrated to provide a measurement of volume flow rate, pressure differential across channel ports, or mass flow rate. High sensitivity, wide dynamic range, and direct digital output are among the attractive features of this sensor. Theoretical expressions for the sensitivity and response time of the sensor are derived. It is shown that by using ultrasonic Lamb waves propagating in thin membranes, a flow sensor with faster response than a SAW sensor can be realized.

  14. Surface-acoustic-wave (SAW) flow sensor.

    PubMed

    Joshi, S G

    1991-01-01

    The use of a surface-acoustic-wave (SAW) device to measure the rate of gas flow is described. A SAW oscillator heated to a suitable temperature above ambient is placed in the path of a flowing gas. Convective cooling caused by the gas flow results in a change in the oscillator frequency. A 73-MHz oscillator fabricated on 128 degrees rotated Y-cut lithium niobate substrate and heated to 55 degrees C above ambient shows a frequency variation greater than 142 kHz for flow-rate variation from 0 to 1000 cm(3)/min. The output of the sensor can be calibrated to provide a measurement of volume flow rate, pressure differential across channel ports, or mass flow rate. High sensitivity, wide dynamic range, and direct digital output are among the attractive features of this sensor. Theoretical expressions for the sensitivity and response time of the sensor are derived. It is shown that by using ultrasonic Lamb waves, propagating in thin membranes, a flow sensor with faster response than a SAW sensor can be realized.

  15. The Hawaiian Volcano Observatory's current approach to forecasting lava flow hazards (Invited)

    NASA Astrophysics Data System (ADS)

    Kauahikaua, J. P.

    2013-12-01

    Hawaiian Volcanoes are best known for their frequent basaltic eruptions, which typically start with fast-moving channelized `a`a flows fed by high eruptions rates. If the flows continue, they generally transition into pahoehoe flows, fed by lower eruption rates, after a few days to weeks. Kilauea Volcano's ongoing eruption illustrates this--since 1986, effusion at Kilauea has mostly produced pahoehoe. The current state of lava flow simulation is quite advanced, but the simplicity of the models mean that they are most appropriately used during the first, most vigorous, days to weeks of an eruption - during the effusion of `a`a flows. Colleagues at INGV in Catania have shown decisively that MAGFLOW simulations utilizing satellite-derived eruption rates can be effective at estimating hazards during the initial periods of an eruption crisis. However, the algorithms do not simulate the complexity of pahoehoe flows. Forecasts of lava flow hazards are the most common form of volcanic hazard assessments made in Hawai`i. Communications with emergency managers over the last decade have relied on simple steepest-descent line maps, coupled with empirical lava flow advance rate information, to portray the imminence of lava flow hazard to nearby communities. Lavasheds, calculated as watersheds, are used as a broader context for the future flow paths and to advise on the utility of diversion efforts, should they be contemplated. The key is to communicate the uncertainty of any approach used to formulate a forecast and, if the forecast uses simple tools, these communications can be fairly straightforward. The calculation of steepest-descent paths and lavasheds relies on the accuracy of the digital elevation model (DEM) used, so the choice of DEM is critical. In Hawai`i, the best choice is not the most recent but is a 1980s-vintage 10-m DEM--more recent LIDAR and satellite radar DEM are referenced to the ellipsoid and include vegetation effects. On low-slope terrain, steepest descent lines calculated on a geoid-based DEM may differ significantly from those calculated on an ellipsoid-based DEM. Good estimates of lava flow advance rates can be obtained from empirical compilations of historical advance rates of Hawaiian lava flows. In this way, rates appropriate for observed flow types (`a`a or pahoehoe, channelized or not) can be applied. Eruption rate is arguably the most important factor, while slope is also significant for low eruption rates. Eruption rate, however, remains the most difficult parameter to estimate during an active eruption. The simplicity of the HVO approach is its major benefit. How much better can lava-flow advance be forecast for all types of lava flows? Will the improvements outweigh the increased uncertainty propagated through the simulation calculations? HVO continues to improve and evaluate its lava flow forecasting tools to provide better hazard assessments to emergency personnel.

  16. Characteristics of Evaporator with a Lipuid-Vapor Separator

    NASA Astrophysics Data System (ADS)

    Ikeguchi, Masaki; Tanaka, Naoki; Yumikura, Tsuneo

    Flow pattern of refrigerant in a heat exchanger tube changes depending on vapor quality, tube diameter, refrigerant flow rate and refrigerant properties. High flow rate causes mist flow where the quality is from 0.8 to 1.0. 1n this flow pattern, the liquid film detaches from the tube wall so that the heat flow is intervened. The heat transfer coefficient generally increases with the flow rate. But the pressure drop of refrigerant flow simultaneously increases and the region of the mist flow enlarges. In order to reduce the pressure drop and suppress the mist flow, we have developped a small liquid-vapor separator that removes the vapor from the evaporating refrigerant flow. This separator is equipped in the middle of the evaporator where the flow pattern is annular. The experiments to evaluate the effect of this separator were carried out and the following conclutions were obtained. (1) Average heat transfer coefficient increases by 30-60 %. (2) Pressure drop reduces by 20-30 %. (3) Cooling Capacity increases by 2-9 %.

  17. An analogue study of the influence of solidification on the advance and surface thermal signature of lava flows

    NASA Astrophysics Data System (ADS)

    Garel, F.; Kaminski, E.; Tait, S.; Limare, A.

    2014-06-01

    The prediction of lava flow advance and velocity is crucial during an effusive volcanic crisis. The effusion rate is a key control of lava dynamics, and proxies have been developed to estimate it in near real-time. The thermal proxy in predominant use links the satellite-measured thermal radiated power to the effusion rate. It lacks however a robust physical basis to allow time-dependent modeling. We investigate here through analogue experiments the coupling between the spreading of a solidifying flow and its surface thermal signal. We extract a first order behavior from experimental results obtained using polyethylene glycol (PEG) wax, that solidifies abruptly during cooling. We find that the flow advance is discontinuous, with relatively low supply rates yielding long stagnation phases and compound flows. Flows with higher supply rates are less sensitive to solidification and display a spreading behavior closer to that of purely viscous currents. The total power radiated from the upper surface also grows by stages, but the signal radiated by the hottest and liquid part of the flow reaches a quasi-steady state after some time. This plateau value scales around half of the theoretical prediction of a model developed previously for the spreading and cooling of isoviscous gravity currents. The corrected scaling yields satisfying estimates of the effusion rate from the total radiated power measured on a range of basaltic lava flows. We conclude that a gross estimate of the supply rate of solidifying flows can be retrieved from thermal remote-sensing, but the predictions of lava advance as a function of effusion rate appears a more difficult task due to chaotic emplacement of solidifying flows.

  18. Research on the performance of low-lift diving tubular pumping system by CFD and Test

    NASA Astrophysics Data System (ADS)

    Xia, Chenzhi; Cheng, Li; Liu, Chao; Zhou, Jiren; Tang, Fangping; Jin, Yan

    2016-11-01

    Post-diving tubular pump is always used in large-discharge & low-head irrigation or storm drainage pumping station, its impeller and motor share the same shaft. Considering diving tubular pump system's excellent hydraulic performance, compact structure, good noise resistance and low operating cost, it is used in Chinese pump stations. To study the hydraulic performance and pressure fluctuation of inlet and outlet passage in diving tubular pump system, both of steady and unsteady full flow fields are numerically simulated at three flow rate conditions by using CFD commercial software. The asymmetry of the longitudinal structure of inlet passage affects the flow pattern on outlet. Especially at small flow rate condition, structural asymmetry will result in the uneven velocity distribution on the outlet of passage inlet. The axial velocity distribution uniformity increases as the flow rate increases on the inlet of passage inlet, and there is a positive correlation between hydraulic loss in the passage inlet and flow rate's quadratic. The axial velocity distribution uniformity on the outlet of passage inlet is 90% at design flow rate condition. The predicted result shows the same trend with test result, and the range of high efficiency area between predicted result and test result is almost identical. The dominant frequency of pressure pulsation is low frequency in inlet passage at design condition. The dominant frequency is high frequency in inlet passage at small and large flow rate condition. At large flow rate condition, the flow pattern is significantly affected by the rotation of impeller in inlet passage. At off-design condition, the pressure pulsation is strong at outlet passage. At design condition, the dominant frequency is 35.57Hz, which is double rotation frequency.

  19. Self-regulating valve

    DOEpatents

    Humphreys, D.A.

    1982-07-20

    A variable, self-regulating valve having a hydraulic loss coefficient proportional to a positive exponential power of the flow rate. The device includes two objects in a flow channel and structure which assures that the distance between the two objects is an increasing function of the flow rate. The range of spacing between the objects is such that the hydraulic resistance of the valve is an increasing function of the distance between the two objects so that the desired hydraulic loss coefficient as a function of flow rate is obtained without variation in the flow area.

  20. A comparison of the flow of iodine 125 through three different intestinal anastomoses: standard, Gambee, and stapler

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wheeless, C.R. Jr.; Smith, J.J.

    1983-10-01

    Angiogenesis determines blood supply, and it is postulated that after surgery, the healing of a wound is directly related to the blood supplied to the surrounding tissues. As a first step in evaluating the process of flow through different surgical anastomoses, the flow rate of /sup 125/I through three different types of anastomoses in the intestines of dogs was determined. When the results were compared, the flow rate through the stapler anastomosis was significantly higher than the flow rate through the standard and Gambee anastomoses.

  1. Energy transfer model and its applications of ultrasonic gas flow-meter under static and dynamic flow rates

    NASA Astrophysics Data System (ADS)

    Fang, Min; Xu, Ke-Jun; Zhu, Wen-Jiao; Shen, Zi-Wen

    2016-01-01

    Most of the ultrasonic gas flow-meters measure the gas flow rate by calculating the ultrasonic transmission time difference between the downstream and upstream. Ultrasonic energy attenuation occurs in the processes of the ultrasonic generation, conversion, transmission, and reception. Additionally, at the same time, the gas flow will also affect the ultrasonic propagation during the measurement, which results in the ultrasonic energy attenuation and the offset of ultrasonic propagation path. Thus, the ultrasonic energy received by the transducer is weaker. When the gas flow rate increases, this effect becomes more apparent. It leads to the measurement accuracy reduced, and the measurement range narrowed. An energy transfer model, where the ultrasonic gas flow-meter under without/with the gas flow, is established by adopting the statistical analysis and curve fitting based on a large amount of experimental data. The static sub model without the gas flow expresses the energy conversion efficiency of ultrasonic gas transducers, and the dynamic sub model with the gas flow reflects the energy attenuation pattern following the flow rate variations. The mathematical model can be used to determine the minimum energy of the excitation signal for meeting the requirement of specific measurement range, and predict the maximum measurable flow rate in the case of fixed energy of excitation signal. Based on the above studies, a method to enhance the excitation signal energy is proposed under the output power of the transmitting circuit being a finite value so as to extend the measurement rage of ultrasonic gas flow-meter.

  2. Pahoehoe and aa in Hawaii: volumetric flow rate controls the lava structure

    NASA Astrophysics Data System (ADS)

    Rowland, Scott K.; Walker, George Pl

    1990-11-01

    The historical records of Kilauea and Mauna Loa volcanoes reveal that the rough-surfaced variety of basalt lava called aa forms when lava flows at a high volumetric rate (>5 10 m3/s), and the smooth-surfaced variety called pahoehoe forms at a low volumetric rate (<5 10 m3/s). This relationship is well illustrated by the 1983 1990 and 1969 1974 eruptions of Kilauea and the recent eruptions of Mauna Loa. It is also illustrated by the eruptions that produced the remarkable paired flows of Mauna Loa, in which aa formed during an initial short period of high discharge rate (associated with high fountaining) and was followed by the eruption of pahoehoe over a sustained period at a low discharge rate (with little or no fountaining). The finest examples of paired lava flows are those of 1859 and 1880 1881. We attribute aa formation to rapid and concentrated flow in open channels. There, rapid heat loss causes an increase in viscosity to a threshold value (that varies depending on the actual flow velocity) at which, when surface crust is torn by differential flow, the underlying lava is unable to move sufficiently fast to heal the tear. We attribute pahoehoe formation to the flowage of lava at a low volumetric rate, commonly in tubes that minimize heat loss. Flow units of pahoehoe are small (usually <1 m thick), move slowly, develop a chilled skin, and become virtually static before the viscosity has risen, to the threshold value. We infer that the high-discharge-rate eruptions that generate aa flows result from the rapid emptying of major or subsidiary magma chambers. Rapid near-surface vesiculation of gas-rich magma leads to eruptions with high discharge rates, high lava fountains, and fast-moving channelized flows. We also infer that long periods of sustained flow at a low discharge rate, which favor pahoehoe, result from the development of a free and unimpeded pathway from the deep plumbing system of the volcano and the separation of gases from the magma before eruption. Achievement of this condition requires one or more episodes of rapid magma excursion through the rift zone to establish a stable magma pathway.

  3. Volumetric Lattice Boltzmann Simulation for Fluid dynamics and Turbulence in Practical Syringes

    NASA Astrophysics Data System (ADS)

    Lima, Everton; Deep, Debanjan; Yu, Huidan (Whitney)

    2012-11-01

    We conduct numerical experiments to study fluid dynamics and turbulence in syringes using volumetric lattice Boltzmann method (VLBM) that is developed for dealing with arbitrary moving boundaries. Several common used medical syringes are used to predict the efficiency and safety of syringes experiencing low flow infusion rates. It is found that smaller size syringes reach a steady flow rate much sooner than larger ones, which are in quantitative agreement with experimental results. The relation between the syringe size and its steady flow rate is revealed. At low flow rates, corner vortices are observed. We explore conditions that lead to turbulent flow aiming to aid safer syringe application in nursing practices.

  4. Hydraulic characteristics of the New River in the New River Gorge National River, West Virginia

    USGS Publications Warehouse

    Wiley, J.B.; Appel, David H.

    1989-01-01

    Traveltime, dispersion, water-surface and streambed profiles, and cross-section data were collected for use in application of flow and solute-transport models to the New River in the New River Gorge National River, West Virginia. Dye clouds subjected to increasing and decreasing flow rates (unsteady flow) showed that increasing flows shorten the cloud and decreasing flows lengthen the cloud. After the flow rate was changed and the flow was again steady, traveltime and dispersion characteristics were determined by the new rate of flow. Seven stage/streamflow relations identified the general changes of stream geometry throughout the study reach. Channel cross sections were estimated for model input. Low water and streambed profiles were developed from surveyed water surface elevations and water depths. (USGS)

  5. Oil field management system

    DOEpatents

    Fincke, James R.

    2003-09-23

    Oil field management systems and methods for managing operation of one or more wells producing a high void fraction multiphase flow. The system includes a differential pressure flow meter which samples pressure readings at various points of interest throughout the system and uses pressure differentials derived from the pressure readings to determine gas and liquid phase mass flow rates of the high void fraction multiphase flow. One or both of the gas and liquid phase mass flow rates are then compared with predetermined criteria. In the event such mass flow rates satisfy the predetermined criteria, a well control system implements a correlating adjustment action respecting the multiphase flow. In this way, various parameters regarding the high void fraction multiphase flow are used as control inputs to the well control system and thus facilitate management of well operations.

  6. Blood flow measurement using digital subtraction angiography for assessing hemodialysis access function

    NASA Astrophysics Data System (ADS)

    Koirala, Nischal; Setser, Randolph M.; Bullen, Jennifer; McLennan, Gordon

    2017-03-01

    Blood flow rate is a critical parameter for diagnosing dialysis access function during fistulography where a flow rate of 600 ml/min in arteriovenous graft or 400-500 ml/min in arteriovenous fistula is considered the clinical threshold for fully functioning access. In this study, a flow rate computational model for calculating intra-access flow to evaluate dialysis access patency was developed and validated in an in vitro set up using digital subtraction angiography. Flow rates were computed by tracking the bolus through two regions of interest using cross correlation (XCOR) and mean arrival time (MAT) algorithms, and correlated versus an in-line transonic flow meter measurement. The mean difference (mean +/- standard deviation) between XCOR and in-line flow measurements for in vitro setup at 3, 6, 7.5 and 10 frames/s was 118+/-63 37+/-59 31+/-31 and 46+/-57 ml/min respectively while for MAT method it was 86+/-56 57+/-72 35+/-85 and 19+/-129 ml/min respectively. The result of this investigation will be helpful for selecting candidate algorithms while blood flow computational tool is developed for clinical application.

  7. Lattice Boltzmann simulation of asymmetric flow in nematic liquid crystals with finite anchoring

    NASA Astrophysics Data System (ADS)

    Zhang, Rui; Roberts, Tyler; Aranson, Igor S.; de Pablo, Juan J.

    2016-02-01

    Liquid crystals (LCs) display many of the flow characteristics of liquids but exhibit long range orientational order. In the nematic phase, the coupling of structure and flow leads to complex hydrodynamic effects that remain to be fully elucidated. Here, we consider the hydrodynamics of a nematic LC in a hybrid cell, where opposite walls have conflicting anchoring boundary conditions, and we employ a 3D lattice Boltzmann method to simulate the time-dependent flow patterns that can arise. Due to the symmetry breaking of the director field within the hybrid cell, we observe that at low to moderate shear rates, the volumetric flow rate under Couette and Poiseuille flows is different for opposite flow directions. At high shear rates, the director field may undergo a topological transition which leads to symmetric flows. By applying an oscillatory pressure gradient to the channel, a net volumetric flow rate is found to depend on the magnitude and frequency of the oscillation, as well as the anchoring strength. Taken together, our findings suggest several intriguing new applications for LCs in microfluidic devices.

  8. Influence of strain rate and temperature on tensile properties and flow behaviour of a reduced activation ferritic-martensitic steel

    NASA Astrophysics Data System (ADS)

    Vanaja, J.; Laha, K.; Sam, Shiju; Nandagopal, M.; Panneer Selvi, S.; Mathew, M. D.; Jayakumar, T.; Rajendra Kumar, E.

    2012-05-01

    Tensile strength and flow behaviour of a Reduced Activation Ferritic-Martensitic (RAFM) steel (9Cr-1W-0.06Ta-0.22V-0.08C) have been investigated over a temperature range of 300-873 K at different strain rates. Tensile strength of the steel decreased with temperature and increased with strain rate except at intermediate temperatures. Negative strain rate sensitivity of flow stress of the steel at intermediate temperatures revealed the occurrence of dynamic strain ageing in the steel, even though no serrated flow was observed. The tensile flow behaviour of the material was well represented by the Voce strain hardening equation for all the test conditions. Temperature and strain rate dependence of the various parameters of Voce equation were interpreted with the possible deformation mechanisms. The equivalence between the saturation stress at a given strain rate in tensile test and steady state deformation rate at a given stress in creep test was found to be satisfied by the RAFM steel.

  9. The Accuracy and Precision of Flow Measurements Using Phase Contrast Techniques

    NASA Astrophysics Data System (ADS)

    Tang, Chao

    Quantitative volume flow rate measurements using the magnetic resonance imaging technique are studied in this dissertation because the volume flow rates have a special interest in the blood supply of the human body. The method of quantitative volume flow rate measurements is based on the phase contrast technique, which assumes a linear relationship between the phase and flow velocity of spins. By measuring the phase shift of nuclear spins and integrating velocity across the lumen of the vessel, we can determine the volume flow rate. The accuracy and precision of volume flow rate measurements obtained using the phase contrast technique are studied by computer simulations and experiments. The various factors studied include (1) the partial volume effect due to voxel dimensions and slice thickness relative to the vessel dimensions; (2) vessel angulation relative to the imaging plane; (3) intravoxel phase dispersion; (4) flow velocity relative to the magnitude of the flow encoding gradient. The partial volume effect is demonstrated to be the major obstacle to obtaining accurate flow measurements for both laminar and plug flow. Laminar flow can be measured more accurately than plug flow in the same condition. Both the experiment and simulation results for laminar flow show that, to obtain the accuracy of volume flow rate measurements to within 10%, at least 16 voxels are needed to cover the vessel lumen. The accuracy of flow measurements depends strongly on the relative intensity of signal from stationary tissues. A correction method is proposed to compensate for the partial volume effect. The correction method is based on a small phase shift approximation. After the correction, the errors due to the partial volume effect are compensated, allowing more accurate results to be obtained. An automatic program based on the correction method is developed and implemented on a Sun workstation. The correction method is applied to the simulation and experiment results. The results show that the correction significantly reduces the errors due to the partial volume effect. We apply the correction method to the data of in vivo studies. Because the blood flow is not known, the results of correction are tested according to the common knowledge (such as cardiac output) and conservation of flow. For example, the volume of blood flowing to the brain should be equal to the volume of blood flowing from the brain. Our measurement results are very convincing.

  10. Ground-water levels, flow, and quality in northwestern Elkhart County, Indiana, 1980-89

    USGS Publications Warehouse

    Duwelius, R.F.; Silcox, C.A.

    1991-01-01

    The time of peak dissolved-bromide concentrations in water from shallow wells downgradient from the landfill was used to estimate a rate of horizontal flow of water in the unconfined aquifer. The average rate of flow between shallow wells downgradient from the landfill was estimated to be 1.2 feet per day. This rate is within the range of values for ground-water flow calculated according to Darcy's law.

  11. A clinical study to compare between resting and stimulated whole salivary flow rate and pH before and after complete denture placement in different age groups

    PubMed Central

    Muddugangadhar, B. C.; Sangur, Rajashekar; Rudraprasad, I. V.; Nandeeshwar, D. B.; Kumar, B. H. Dhanya

    2015-01-01

    Purpose: This study compared the flow rate and pH of resting (unstimulated) and stimulated whole saliva before and after complete denture placement in different age groups. Materials and Methods: Fifty healthy, non-medicated edentulous individuals of different age groups requiring complete denture prostheses were selected from the outpatient department. The resting (unstimulated) and stimulated whole saliva and pH were measured at three stages i.e., i)Before complete denture placement;ii)Immediately after complete denture placement; andiii)After 2 to 3 months of complete denture placement. Saliva production was stimulated by chewing paraffin wax. pH was determined by using a digital pH meter. Results: Statistically significant differences were seen in resting(unstimulated) and stimulated whole salivary flow rate and pH obtained before, immediately after, and after 2 to 3 months of complete denture placement. No statistically significant differences were found between the different age groups in resting (unstimulated) as well as stimulated whole salivary flow rate and pH. Conclusion: Stimulated whole salivary flow rates and pH were significantly higher than resting (unstimulated) whole salivary flow rates and pH obtained before, immediately after, and after 2 to 3 months of complete denture placement. No age related variations in whole salivary flow rate and pH were observed in healthy, non-medicated individuals. Clinical Implications: The assessment of salivary flow rate, pH in different age groups is of prognostic value, which is an important aspect to be considered in the practice of removable prosthodontics. PMID:26929540

  12. Effects of dose, flow rate, and bile acid on diclofenac disposition in the perfused rat liver.

    PubMed

    Uraki, Misato; Kawase, Atsushi; Matsushima, Yuka; Iwaki, Masahiro

    2016-06-01

    An in situ perfused rat liver system is useful for studying the hepatic disposition of drugs and their metabolites. However, the effects of the perfusion conditions on drug disposition are unclear. We examined the effects of conditions such as flow rate (13 or 26 mL/min) and bile acid on disposition of diclofenac (DF) as a model drug and DF metabolites [diclofenac-1-O-acyl glucuronide (DF-Glu) or 4'-hydroxydiclofenac (DF-4'OH)] in the absence of albumin. DF, DF-Glu, and DF-4'OH concentrations in the perfusate and cumulative amounts of DF-Glu excreted in bile were measured using high-performance liquid chromatography methods. DF in the perfusate was rapidly eliminated as the perfusate flow rate increased. The area under the plasma concentration-time curve from 0 to 60 min (AUC0-60) for DF-Glu and DF-4'OH in a perfusate containing bile acid was lower at a flow rate of 26 and 13 mL/min, respectively. The bile flow rate at 26 mL/min with 24 μM of bile acid in the perfusate was significantly higher (ca. 3.5 times) compared with that at 13 mL/min without bile acid. Cumulative biliary DF-Glu excretion was also dramatically affected by the flow rate and addition of bile acid. This study indicated that the flow rate and bile acid in the perfused rat liver were key factors for bile flow rate and DF, DF-Glu, and DF-4'OH disposition in the absence of albumin.

  13. A clinical study to compare between resting and stimulated whole salivary flow rate and pH before and after complete denture placement in different age groups.

    PubMed

    Muddugangadhar, B C; Sangur, Rajashekar; Rudraprasad, I V; Nandeeshwar, D B; Kumar, B H Dhanya

    2015-01-01

    This study compared the flow rate and pH of resting (unstimulated) and stimulated whole saliva before and after complete denture placement in different age groups. Fifty healthy, non-medicated edentulous individuals of different age groups requiring complete denture prostheses were selected from the outpatient department. The resting (unstimulated) and stimulated whole saliva and pH were measured at three stages i.e., i)Before complete denture placement;ii)Immediately after complete denture placement; andiii)After 2 to 3 months of complete denture placement. Saliva production was stimulated by chewing paraffin wax. pH was determined by using a digital pH meter. Statistically significant differences were seen in resting(unstimulated) and stimulated whole salivary flow rate and pH obtained before, immediately after, and after 2 to 3 months of complete denture placement. No statistically significant differences were found between the different age groups in resting (unstimulated) as well as stimulated whole salivary flow rate and pH. Stimulated whole salivary flow rates and pH were significantly higher than resting (unstimulated) whole salivary flow rates and pH obtained before, immediately after, and after 2 to 3 months of complete denture placement. No age related variations in whole salivary flow rate and pH were observed in healthy, non-medicated individuals. The assessment of salivary flow rate, pH in different age groups is of prognostic value, which is an important aspect to be considered in the practice of removable prosthodontics.

  14. Flow rate calibration to determine cell-derived microparticles and homogeneity of blood components.

    PubMed

    Noulsri, Egarit; Lerdwana, Surada; Kittisares, Kulvara; Palasuwan, Attakorn; Palasuwan, Duangdao

    2017-08-01

    Cell-derived microparticles (MPs) are currently of great interest to screening transfusion donors and blood components. However, the current approach to counting MPs is not affordable for routine laboratory use due to its high cost. The current study aimed to investigate the potential use of flow-rate calibration for counting MPs in whole blood, packed red blood cells (PRBCs), and platelet concentrates (PCs). The accuracy of flow-rate calibration was investigated by comparing the platelet counts of an automated counter and a flow-rate calibrator. The concentration of MPs and their origins in whole blood (n=100), PRBCs (n=100), and PCs (n=92) were determined using a FACSCalibur. The MPs' fold-changes were calculated to assess the homogeneity of the blood components. Comparing the platelet counts conducted by automated counting and flow-rate calibration showed an r 2 of 0.6 (y=0.69x+97,620). The CVs of the within-run and between-run variations of flow-rate calibration were 8.2% and 12.1%, respectively. The Bland-Altman plot showed a mean bias of -31,142platelets/μl. MP enumeration revealed both the difference in MP levels and their origins in whole blood, PRBCs, and PCs. Screening the blood components demonstrated high heterogeneity of the MP levels in PCs when compared to whole blood and PRBCs. The results of the present study suggest the accuracy and precision of flow-rate calibration for enumerating MPs. This flow-rate approach is affordable for assessing the homogeneity of MPs in blood components in routine laboratory practice. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Linear growth rates of resistive tearing modes with sub-Alfvénic streaming flow

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, L. N.; College of Sciences, China Jiliang University, Hangzhou 310018; Ma, Z. W., E-mail: zwma@zju.edu.cn

    2014-07-15

    The tearing instability with sub-Alfvénic streaming flow along the external magnetic field is investigated using resistive MHD simulation. It is found that the growth rate of the tearing mode instability is larger than that without the streaming flow. With the streaming flow, there exist two Alfvén resonance layers near the central current sheet. The larger perturbation of the magnetic field in two closer Alfvén resonance layers could lead to formation of the observed cone structure and can largely enhance the development of the tearing mode for a narrower streaming flow. For a broader streaming flow, a larger separation of Alfvénmore » resonance layers reduces the magnetic reconnection. The linear growth rate decreases with increase of the streaming flow thickness. The growth rate of the tearing instability also depends on the plasma beta (β). When the streaming flow is embedded in the current sheet, the growth rate increases with β if β < β{sub s}, but decreases if β > β{sub s}. The existence of the specific value β{sub s} can be attributed to competition between the suppressing effect of β and the enhancing effect of the streaming flow on the magnetic reconnection. The critical value β{sub s} increases with increase of the streaming flow strength.« less

  16. Heat transfer in a microvascular network: the effect of heart rate on heating and cooling in reptiles (Pogona barbata and Varanus varius).

    PubMed

    Seebacher, F

    2000-03-21

    Thermally-induced changes in heart rate and blood flow in reptiles are believed to be of selective advantage by allowing animal to exert some control over rates of heating and cooling. This notion has become one of the principal paradigms in reptilian thermal physiology. However, the functional significance of changes in heart rate is unclear, because the effect of heart rate and blood flow on total animal heat transfer is not known. I used heat transfer theory to determine the importance of heat transfer by blood flow relative to conduction. I validated theoretical predictions by comparing them with field data from two species of lizard, bearded dragons (Pogona barbata) and lace monitors (Varanus varius). Heart rates measured in free-ranging lizards in the field were significantly higher during heating than during cooling, and heart rates decreased with body mass. Convective heat transfer by blood flow increased with heart rate. Rates of heat transfer by both blood flow and conduction decreased with mass, but the mass scaling exponents were different. Hence, rate of conductive heat transfer decreased more rapidly with increasing mass than did heat transfer by blood flow, so that the relative importance of blood flow in total animal heat transfer increased with mass. The functional significance of changes in heart rate and, hence, rates of heat transfer, in response to heating and cooling in lizards was quantified. For example, by increasing heart rate when entering a heating environment in the morning, and decreasing heart rate when the environment cools in the evening a Pogona can spend up to 44 min longer per day with body temperature within its preferred range. It was concluded that changes in heart rate in response to heating and cooling confer a selective advantage at least on reptiles of mass similar to that of the study animals (0. 21-5.6 kg). Copyright 2000 Academic Press.

  17. A COMPREHENSIVE STUDY OF HOURLY AND DAILY SEWAGE FLOW RATES IN FLORIDA PUBLIC SCHOOLS.

    ERIC Educational Resources Information Center

    FOGARTY, WILLIAM J.; REEDER, MILTON E.

    A DETERMINATION OF THE HOURLY AND DAILY SEWAGE FLOW RATES IN FLORIDA PUBLIC SCHOOLS WAS MADE TO IDENTIFY THE FLOW CHARACTERISTICS AND TO PROVIDE A MORE PRECISE BASIS FOR THE ESTABLISHMENT OF DESIGN CRITERIA FOR SEWAGE DISPOSAL FACILITIES IN SCHOOLS. WATER FLOW DATA WAS COLLECTED FOR 158 SCHOOLS AND SEWAGE FLOW DATA FROM 42 SCHOOLS. THE FINDINGS…

  18. Turbulence modeling and surface heat transfer in a stagnation flow region

    NASA Technical Reports Server (NTRS)

    Wang, C. R.; Yeh, F. C.

    1987-01-01

    Analysis for the turbulent flow field and the effect of freestream turbulence on the surface heat transfer rate of a stagnation flow is presented. The emphasis is on modeling and its augmentation of surface heat transfer rate. The flow field considered is the region near the forward stagnation point of a circular cylinder in a uniform turbulent mean flow.

  19. Permafrost thaw in a nested groundwater-flow system

    USGS Publications Warehouse

    McKenzie, Jeffery M.; Voss, Clifford I.

    2013-01-01

    Groundwater flow in cold regions containing permafrost accelerates climate-warming-driven thaw and changes thaw patterns. Simulation analyses of groundwater flow and heat transport with freeze/thaw in typical cold-regions terrain with nested flow indicate that early thaw rate is particularly enhanced by flow, the time when adverse environmental impacts of climate-warming-induced permafrost loss may be severest. For the slowest climate-warming rate predicted by the Intergovernmental Panel on Climate Change (IPCC), once significant groundwater flow begins, thick permafrost layers can vanish in several hundred years, but survive over 1,000 years where flow is minimal. Large-scale thaw depends mostly on the balance of heat advection and conduction in the supra-permafrost zone. Surface-water bodies underlain by open taliks allow slow sub-permafrost flow, with lesser influence on regional thaw. Advection dominance over conduction depends on permeability and topography. Groundwater flow around permafrost and flow through permafrost impact thaw differently; the latter enhances early thaw rate. Air-temperature seasonality also increases early thaw. Hydrogeologic heterogeneity and topography strongly affect thaw rates/patterns. Permafrost controls the groundwater/surface-water-geomorphology system; hence, prediction and mitigation of impacts of thaw on ecology, chemical exports and infrastructure require improved hydrogeology/permafrost characterization and understanding

  20. Estimation of Blood Flow Rates in Large Microvascular Networks

    PubMed Central

    Fry, Brendan C.; Lee, Jack; Smith, Nicolas P.; Secomb, Timothy W.

    2012-01-01

    Objective Recent methods for imaging microvascular structures provide geometrical data on networks containing thousands of segments. Prediction of functional properties, such as solute transport, requires information on blood flow rates also, but experimental measurement of many individual flows is difficult. Here, a method is presented for estimating flow rates in a microvascular network based on incomplete information on the flows in the boundary segments that feed and drain the network. Methods With incomplete boundary data, the equations governing blood flow form an underdetermined linear system. An algorithm was developed that uses independent information about the distribution of wall shear stresses and pressures in microvessels to resolve this indeterminacy, by minimizing the deviation of pressures and wall shear stresses from target values. Results The algorithm was tested using previously obtained experimental flow data from four microvascular networks in the rat mesentery. With two or three prescribed boundary conditions, predicted flows showed relatively small errors in most segments and fewer than 10% incorrect flow directions on average. Conclusions The proposed method can be used to estimate flow rates in microvascular networks, based on incomplete boundary data and provides a basis for deducing functional properties of microvessel networks. PMID:22506980

  1. 40 CFR Appendix E to Part 52 - Performance Specifications and, Specification Test Procedures for Monitoring Systems for Effluent...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., Specification Test Procedures for Monitoring Systems for Effluent Stream Gas Volumetric Flow Rate E Appendix E... Stream Gas Volumetric Flow Rate 1. Principle and applicability. 1.1Principle. Effluent stream gas... method is applicable to subparts which require continuous gas volumetric flow rate measurement...

  2. 40 CFR Appendix E to Part 52 - Performance Specifications and, Specification Test Procedures for Monitoring Systems for Effluent...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., Specification Test Procedures for Monitoring Systems for Effluent Stream Gas Volumetric Flow Rate E Appendix E... Stream Gas Volumetric Flow Rate 1. Principle and applicability. 1.1Principle. Effluent stream gas... method is applicable to subparts which require continuous gas volumetric flow rate measurement...

  3. 40 CFR 98.245 - Procedures for estimating missing data.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 22 2012-07-01 2012-07-01 false Procedures for estimating missing data... estimating missing data. For missing feedstock flow rates, product flow rates, and carbon contents, use the same procedures as for missing flow rates and carbon contents for fuels as specified in § 98.35. ...

  4. 40 CFR 98.245 - Procedures for estimating missing data.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 21 2011-07-01 2011-07-01 false Procedures for estimating missing data... estimating missing data. For missing feedstock flow rates, product flow rates, and carbon contents, use the same procedures as for missing flow rates and carbon contents for fuels as specified in § 98.35. ...

  5. 40 CFR 98.245 - Procedures for estimating missing data.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 22 2013-07-01 2013-07-01 false Procedures for estimating missing data... estimating missing data. For missing feedstock flow rates, product flow rates, and carbon contents, use the same procedures as for missing flow rates and carbon contents for fuels as specified in § 98.35. ...

  6. 40 CFR 98.245 - Procedures for estimating missing data.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Procedures for estimating missing data... estimating missing data. For missing feedstock flow rates, product flow rates, and carbon contents, use the same procedures as for missing flow rates and carbon contents for fuels as specified in § 98.35. ...

  7. 40 CFR 63.1656 - Performance testing, test methods, and compliance demonstrations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... points. (2) Method 2 to determine the volumetric flow rate of the stack gas. (3) Method 3 to determine... matter concentration and volumetric flow rate of the stack gas for positive pressure baghouses without...) Determine the particulate matter concentration and volumetric flow rate using Method 5 or 5D, as applicable...

  8. 40 CFR 63.1656 - Performance testing, test methods, and compliance demonstrations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... points. (2) Method 2 to determine the volumetric flow rate of the stack gas. (3) Method 3 to determine... matter concentration and volumetric flow rate of the stack gas for positive pressure baghouses without...) Determine the particulate matter concentration and volumetric flow rate using Method 5 or 5D, as applicable...

  9. 40 CFR 63.1656 - Performance testing, test methods, and compliance demonstrations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... points. (2) Method 2 to determine the volumetric flow rate of the stack gas. (3) Method 3 to determine... matter concentration and volumetric flow rate of the stack gas for positive pressure baghouses without...) Determine the particulate matter concentration and volumetric flow rate using Method 5 or 5D, as applicable...

  10. Standardization of a simple method to study whole saliva: clinical use in different pathologies.

    PubMed

    Tumilasci, Omar R; Cardoso, Estela M L; Contreras, Liliana N; Belforte, Juan; Arregger, Alejandro L; Ostuni, Mariano A

    2006-01-01

    The present study describes a methodology to assess the salivary flow rate in humans. Whole saliva was obtained from the floor of the mouth with a plastic dental ejector and a vacuum pump. Forty healthy subjects of both sexes and 51 patients with different pathologies (Sjögren Syndrome, Thyroid Dysfunction, Diabetes Mellitus) were included in the study. It was demonstrated that basal salivary flow rate was stable five minutes after the insertion of the oral ejector Salivary flow rate did not show significant differences between sexes and was independent of the negative pressure level of the vacuum pump. Stimulated salivary flow rate was quantified over a period of 3 minutes, starting 5 minutes after the introduction of the oral device. The stimulus was paper filter disks soaked in citric acid (2%) placed on the tongue dorsum. The use of this method confirmed the reduction of salivary flow rate in patients with Sjiigren Syndrome. In addition, a significant reduction in salivary flow rate was observed in patients with primary thyroid insufficiency and peripheral neurpathy secondary to Diabetes Mellitus.

  11. 14 CFR 23.955 - Fuel flow.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Fuel System § 23.955 Fuel flow. (a) General. The ability of the fuel system to provide fuel at the rates specified in this... drive flow, and for all other purposes for which fuel is used. (b) Gravity systems. The fuel flow rate...

  12. 14 CFR 23.955 - Fuel flow.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Fuel System § 23.955 Fuel flow. (a) General. The ability of the fuel system to provide fuel at the rates specified in this... drive flow, and for all other purposes for which fuel is used. (b) Gravity systems. The fuel flow rate...

  13. 14 CFR 23.955 - Fuel flow.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Fuel System § 23.955 Fuel flow. (a) General. The ability of the fuel system to provide fuel at the rates specified in this... drive flow, and for all other purposes for which fuel is used. (b) Gravity systems. The fuel flow rate...

  14. 14 CFR 23.955 - Fuel flow.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Fuel System § 23.955 Fuel flow. (a) General. The ability of the fuel system to provide fuel at the rates specified in this... drive flow, and for all other purposes for which fuel is used. (b) Gravity systems. The fuel flow rate...

  15. 14 CFR 23.955 - Fuel flow.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Fuel System § 23.955 Fuel flow. (a) General. The ability of the fuel system to provide fuel at the rates specified in this... drive flow, and for all other purposes for which fuel is used. (b) Gravity systems. The fuel flow rate...

  16. Economic method for measuring ultra-low flow rates of fluids

    NASA Technical Reports Server (NTRS)

    Bogdanovic, J. A.; Keller, W. F.

    1970-01-01

    Capillary tube flowmeter measures ultra-low flows of very corrosive fluids /such as chlorine trifluoride and liquid fluorine/ and other liquids with reasonable accuracy. Flowmeter utilizes differential pressure transducer and operates on the principle that for laminar flow in the tube, pressure drop is proportional to flow rate.

  17. 40 CFR 90.301 - Applicability.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the test engine is operated using a steady state test cycle on an engine dynamometer. The exhaust... concentrations are converted to mass emission rates in grams per hour based on either fuel flow, fuel flow and engine intake air flow, or exhaust volume flow. Weighted emission rates are reported as grams per brake...

  18. Transient shear banding in the nematic dumbbell model of liquid crystalline polymers

    NASA Astrophysics Data System (ADS)

    Adams, J. M.; Corbett, D.

    2018-05-01

    In the shear flow of liquid crystalline polymers (LCPs) the nematic director orientation can align with the flow direction for some materials but continuously tumble in others. The nematic dumbbell (ND) model was originally developed to describe the rheology of flow-aligning semiflexible LCPs, and flow-aligning LCPs are the focus in this paper. In the shear flow of monodomain LCPs, it is usually assumed that the spatial distribution of the velocity is uniform. This is in contrast to polymer solutions, where highly nonuniform spatial velocity profiles have been observed in experiments. We analyze the ND model, with an additional gradient term in the constitutive model, using a linear stability analysis. We investigate the separate cases of constant applied shear stress and constant applied shear rate. We find that the ND model has a transient flow instability to the formation of a spatially inhomogeneous flow velocity for certain starting orientations of the director. We calculate the spatially resolved flow profile in both constant applied stress and constant applied shear rate in start up from rest, using a model with one spatial dimension to illustrate the flow behavior of the fluid. For low shear rates flow reversal can be seen as the director realigns with the flow direction, whereas for high shear rates the director reorientation occurs simultaneously across the gap. Experimentally, this inhomogeneous flow is predicted to be observed in flow reversal experiments in LCPs.

  19. Nofoam System Technology for Aircraft Hangar Fire Suppression Foam System

    DTIC Science & Technology

    2011-07-01

    use of a firefighting agent that meets Military Specification MIL - F - 24385 [Reference 2]. Significant amounts of AFFF wastewater is generated...rates, Table 3, were the established baseline for comparison. Table 3 theoretical flow rates were derived from Military Specification MIL - F - 24385 [Reference...flow rates, Table 3, was the established baseline for comparison. Table 3 theoretical flow rates were derived from Military Specification MIL - F - 24385 [Reference

  20. Electro-osmotically driven liquid delivery method and apparatus

    DOEpatents

    Rakestraw, David J.; Anex, Deon S.; Yan, Chao; Dadoo, Rajeev; Zare, Richard N.

    1999-01-01

    Method and apparatus for controlling precisely the composition and delivery of liquid at sub-.mu.L/min flow rate. One embodiment of such a delivery system is an electro-osmotically driven gradient flow delivery system that generates dynamic gradient flows with sub-.mu.L/min flow rates by merging a plurality of electro-osmotic flows. These flows are delivered by a plurality of delivery arms attached to a mixing connector, where they mix and then flow into a receiving means, preferably a column. Each inlet of the plurality of delivery arms is placed in a corresponding solution reservoir. A plurality of independent programmable high-voltage power supplies is used to apply a voltage program to each of the plurality of solution reservoirs to regulate the electro-osmotic flow in each delivery arm. The electro-osmotic flow rates in the delivery arms are changed with time according to each voltage program to deliver the required gradient profile to the column.

  1. Apparatus for monitoring two-phase flow

    DOEpatents

    Sheppard, John D.; Tong, Long S.

    1977-03-01

    A method and apparatus for monitoring two-phase flow is provided that is particularly related to the monitoring of transient two-phase (liquid-vapor) flow rates such as may occur during a pressurized water reactor core blow-down. The present invention essentially comprises the use of flanged wire screens or similar devices, such as perforated plates, to produce certain desirable effects in the flow regime for monitoring purposes. One desirable effect is a measurable and reproducible pressure drop across the screen. The pressure drop can be characterized for various known flow rates and then used to monitor nonhomogeneous flow regimes. Another useful effect of the use of screens or plates in nonhomogeneous flow is that such apparatus tends to create a uniformly dispersed flow regime in the immediate downstream vicinity. This is a desirable effect because it usually increases the accuracy of flow rate measurements determined by conventional methods.

  2. Method and apparatus for monitoring two-phase flow. [PWR

    DOEpatents

    Sheppard, J.D.; Tong, L.S.

    1975-12-19

    A method and apparatus for monitoring two-phase flow is provided that is particularly related to the monitoring of transient two-phase (liquid-vapor) flow rates such as may occur during a pressurized water reactor core blow-down. The present invention essentially comprises the use of flanged wire screens or similar devices, such as perforated plates, to produce certain desirable effects in the flow regime for monitoring purposes. One desirable effect is a measurable and reproducible pressure drop across the screen. The pressure drop can be characterized for various known flow rates and then used to monitor nonhomogeneous flow regimes. Another useful effect of the use of screens or plates in nonhomogeneous flow is that such apparatus tends to create a uniformly dispersed flow regime in the immediate downstream vicinity. This is a desirable effect because it usually increases the accuracy of flow rate measurements determined by conventional methods.

  3. Modelling the growth Rate of Algal in sediment-laden flow

    NASA Astrophysics Data System (ADS)

    Li, H.

    2017-12-01

    Phytoplankton plays an important role as a primary producer in aquatic ecosystems. Fluid dynamics can affect the growth of algae in a number of ways and can be divided into two categories. On the one hand the advection and diffusion processes may disrupt the vertical migration of phytoplankton. On the other hand hydrodynamic effects of sediment suspension which can affect algal growth, by releasing nutrients and reducing light intensity. Natural water generally contains sediment. Therefore, when the flow enters the lake, it will cause a change in the phytoplankton community at the junction. Few people have studied the effects of sediment-laden flows to algal growth rates. In this project, Baiyangdian was chosen as the key research area to study the effect of sediment-laden flow on the growth rate of algae. And we conducted a microcosmic experiment in the laboratory to simulate the effect of sediment-laden flow on the growth rate of algae, and constructed a numerical model for the growth rate of algae in sediment-laden flow.

  4. The temporal evolution of the resistive pressure-gradient-driven turbulence and anomalous transport in shear flow across the magnetic field

    NASA Astrophysics Data System (ADS)

    Lee, Hae June; Mikhailenko, Vladmir; Mikhailenko, Vladimir

    2017-10-01

    The temporal evolution of the resistive pressure-gradient-driven mode in the sheared flow is investigated by employing the shearing modes approach. It reveals an essential difference in the processes, which occur in the case of the flows with velocity shearing rate less than the growth rate of the instability in the steady plasmas, and in the case of the flows with velocity shear larger than the instability growth rate in steady plasmas. It displays the physical content of the empirical ``quench rule'' which predicts the suppression of the turbulence in the sheared flows when the velocity shearing rate becomes larger than the maximum growth rate of the possible instability. We found that the distortion of the perturbations by the sheared flow with such velocity shear introduces the time dependencies into the governing equations, which prohibits the application of the eigenmodes formalism and requires the solution of the initial value problem.

  5. Multiphase flow calculation software

    DOEpatents

    Fincke, James R.

    2003-04-15

    Multiphase flow calculation software and computer-readable media carrying computer executable instructions for calculating liquid and gas phase mass flow rates of high void fraction multiphase flows. The multiphase flow calculation software employs various given, or experimentally determined, parameters in conjunction with a plurality of pressure differentials of a multiphase flow, preferably supplied by a differential pressure flowmeter or the like, to determine liquid and gas phase mass flow rates of the high void fraction multiphase flows. Embodiments of the multiphase flow calculation software are suitable for use in a variety of applications, including real-time management and control of an object system.

  6. Vacuum-bag-only processing of composites

    NASA Astrophysics Data System (ADS)

    Thomas, Shad

    Ultrasonic imaging in the C-scan mode in conjunction with the amplitude of the reflected signal was used to measure flow rates of an epoxy resin film penetrating through the thickness of single layers of woven carbon fabric. Assemblies, comprised of a single layer of fabric and film, were vacuum-bagged and ultrasonically scanned in a water tank during impregnation at 50°C, 60°C, 70°C, and 80°C. Measured flow rates were plotted versus inverse viscosity to determine the permeability in the thin film, non-saturated system. The results demonstrated that ultrasonic imaging in the C-scan mode is an effective method of measuring z-direction resin flow through a single layer of fabric. The permeability values determined in this work were consistent with permeability values reported in the literature. Capillary flow was not observed at the temperatures and times required for pressurized flow to occur. The flow rate at 65°C was predicted from the linear plot of flow rate versus inverse viscosity. The effects of fabric architecture on through-thickness flow rates during impregnation of an epoxy resin film were measured by ultrasonic imaging. Multilayered laminates comprised of woven carbon fabrics and epoxy films (prepregs) were fabricated by vacuum-bagging. Ultrasonic imaging was performed in a heated water tank (65°C) during impregnation. Impregnation rates showed a strong dependence on fabric architecture, despite similar areal densities. Impregnation rates are directly affected by inter-tow spacing and tow nesting, which depend on fabric architecture, and are indirectly affected by areal densities. A new method of predicting resin infusion rates in prepreg and resin film infusion processes was proposed. The Stokes equation was used to derive an equation to predict the impregnation rate of laminates as a function of fabric architecture. Flow rate data previously measured by ultrasound was analyzed with the new equation and the Kozeny-Carman equation. A fiber interaction parameter was determined as a function of fabric architecture. The derived equation is straight-forward to use, unlike the Kozeny-Carman equation. The results demonstrated that the newly derived equation can be used to predict the resin infusion rate of multilayer laminates.

  7. Numerical simulations of the Macondo well blowout reveal strong control of oil flow by reservoir permeability and exsolution of gas

    PubMed Central

    Oldenburg, Curtis M.; Freifeld, Barry M.; Pruess, Karsten; Pan, Lehua; Finsterle, Stefan; Moridis, George J.

    2012-01-01

    In response to the urgent need for estimates of the oil and gas flow rate from the Macondo well MC252-1 blowout, we assembled a small team and carried out oil and gas flow simulations using the TOUGH2 codes over two weeks in mid-2010. The conceptual model included the oil reservoir and the well with a top boundary condition located at the bottom of the blowout preventer. We developed a fluid properties module (Eoil) applicable to a simple two-phase and two-component oil-gas system. The flow of oil and gas was simulated using T2Well, a coupled reservoir-wellbore flow model, along with iTOUGH2 for sensitivity analysis and uncertainty quantification. The most likely oil flow rate estimated from simulations based on the data available in early June 2010 was about 100,000 bbl/d (barrels per day) with a corresponding gas flow rate of 300 MMscf/d (million standard cubic feet per day) assuming the well was open to the reservoir over 30 m of thickness. A Monte Carlo analysis of reservoir and fluid properties provided an uncertainty distribution with a long tail extending down to 60,000 bbl/d of oil (170 MMscf/d of gas). The flow rate was most strongly sensitive to reservoir permeability. Conceptual model uncertainty was also significant, particularly with regard to the length of the well that was open to the reservoir. For fluid-entry interval length of 1.5 m, the oil flow rate was about 56,000 bbl/d. Sensitivity analyses showed that flow rate was not very sensitive to pressure-drop across the blowout preventer due to the interplay between gas exsolution and oil flow rate. PMID:21730177

  8. Macropore system characteristics controls on non-reactive solute transport at different flow rates

    NASA Astrophysics Data System (ADS)

    Larsbo, Mats; Koestel, John

    2014-05-01

    Preferential flow and transport in macroporous soils are important pathways for the leaching of agrochemicals through soils. Preferential solute transport in soil is to a large extent determined by the macropore system characteristics and the water flow conditions. The importance of different characteristics of the macropore system is likely to vary with the flow conditions. The objective of this study was to determine which properties of the macropore system that control the shape of non-reactive tracer solute breakthrough curves at different steady-state flow rates. We sampled five undisturbed columns (20 cm high, 20 cm diameter) from the soil surface of four soils with clay contents between 21 and 50 %. Solute transport experiments were carried out under unsaturated conditions at 2, 4, 6, 8 and 12 mm h-1 flow rates. For each flow rate a pulse of potassium bromide solution was applied at the soil surface and the electrical conductivity was measured with high temporal resolution in the column effluent. We used the 5 % arrival time and the holdback factor to estimate the degree of preferential transport from the resulting breakthrough curves. Unsaturated hydraulic conductivities were measured at the soil surface of the columns using a tension disc infiltrometer. The macropore system was imaged by industrial X-ray computed tomography at a resolution of 125 μm in all directions. Measures of the macropore system characteristics including measures of pore continuity were calculated from these images using the ImageJ software. Results show that the degree of preferential transport is generally increasing with flow rate when larger pores become active in the transport. The degree of preferential flow was correlated to measures of macropore topology. This study show that conclusions drawn from experiments carried out at one flow rate should generally not be extrapolated to other flow rates.

  9. An Optical Study of Processes in Hydrogen Flame in a Tube

    DTIC Science & Technology

    2002-07-01

    growth of the hydrogen- flame length with the hydrogen flow rate was observed, whereas for a turbulent hydrogen jet (Reynolds number Re > 104 [5]), the... flame length remained almost constant and varied only weakly with the flow rate of hydrogen. For a subsonic jet flow, flame images display an...There are some data in the literature which show how the diffusive- flame length varies with the rate of hydrogen flow [4, 7]. The length of a

  10. Assessment of a miniature four-roll mill and a cross-slot microchannel for high-strain-rate stagnation point flows

    NASA Astrophysics Data System (ADS)

    Akbaridoust, Farzan; Philip, Jimmy; Marusic, Ivan

    2018-04-01

    Stagnation point flows have been widely used to study the deformation and break-up of objects in two-dimensional pure straining flows. Here, we report a systematic study of the characterisation of stagnation point flows in two devices, a miniature Taylor’s four-roll mill and a cross-slot microchannel. The aim of the study is to find the best platform suitable for investigating the effect of strain rate on the mechanical properties of waterborne microorganisms. Using micro-PIV, the velocity field and the strain rates in both devices were measured at different flow rates and compared with an ideal hyperbolic stagnation point flow. The cross-slot microchannel was found to be a better experimental device than the miniature four-roll mill for the purpose of confining micron-sized objects in a controlled stagnation point flow. This is mainly due to the difficulty of maintaining a fixed location for the stagnation point within one micron in the miniature four-roll mill and achieving high strain rates beyond 10 s-1 . However, with no moving parts, the cross-slot microchannel was found to maintain a steady flow, with the stagnation point varying less than one micron at a cross-junction of 400× 400~μm2 , and was able to reach uniform strain rates up to 140 s-1 .

  11. Laminar and turbulent flow modes of cold atmospheric pressure argon plasma jet

    NASA Astrophysics Data System (ADS)

    Basher, Abdulrahman H.; Mohamed, Abdel-Aleam H.

    2018-05-01

    Laminar and turbulent flow modes of a cold atmospheric pressure argon plasma jet are investigated in this work. The effects of the gas flow rate, applied voltage, and frequency on each plasma mode and on intermodal transitions are characterized using photographic, electrical, and spectroscopic techniques. Increasing the gas flow rate increases the plasma jet length in the laminar mode. Upon transition to the turbulent mode, increasing the gas flow rate leads to a decrease in the plasma jet length. The flow rate at which the jet transitions from laminar to turbulent increases with the applied voltage. The presence of nitric oxide (NO) radicals is indicated by the emission spectra of the turbulent plasmas only, while excited Ar, N2, OH, and O excited species are produced in both laminar and turbulent modes. With no distinctive behavior observed upon transition between the two operating modes, the power consumption was found to be insensitive to gas flow rate variation, while the energy density was found to decrease exponentially with the gas flow rate. Rotational and vibrational temperature measurements of the two plasma modes indicated that they are of the non-thermal equilibrium plasma type. Since they offer NO radicals while maintaining the benefits of the laminar plasma jet, the turbulent plasma jet is more useful than its laminar counterpart in biomedical applications.

  12. Simulation of two-dimensional adjustable liquid gradient refractive index (L-GRIN) microlens

    NASA Astrophysics Data System (ADS)

    Le, Zichun; Wu, Xiang; Sun, Yunli; Du, Ying

    2017-07-01

    In this paper, a two-dimensional liquid gradient refractive index (L-GRIN) microlens is designed which can be used in adjusting focusing direction and focal spot of light beam. Finite element method (FEM) is used to simulate the convection diffusion process happening in core inlet flow and cladding inlet flow. And the ray tracing method shows us the light beam focusing effect including the extrapolation of focal length and output beam spot size. When the flow rates of the core and cladding fluids are held the same between the internal and external, left and right, and upper and lower inlets, the focal length varied from 313 μm to 53.3 μm while the flow rate of liquids ranges from 500 pL/s to 10,000 pL/s. While the core flow rate is bigger than the cladding inlet flow rate, the light beam will focus on a light spot with a tunable size. By adjusting the ratio of cladding inlet flow rate including Qright/Qleft and Qup/Qdown, we get the adjustable two-dimensional focus direction rather than the one-dimensional focusing. In summary, by adjusting the flow rate of core inlet and cladding inlet, the focal length, output beam spot and focusing direction of the input light beam can be manipulated. We suppose this kind of flexible microlens can be used in integrated optics and lab-on-a-chip system.

  13. The wire-mesh sensor as a two-phase flow meter

    NASA Astrophysics Data System (ADS)

    Shaban, H.; Tavoularis, S.

    2015-01-01

    A novel gas and liquid flow rate measurement method is proposed for use in vertical upward and downward gas-liquid pipe flows. This method is based on the analysis of the time history of area-averaged void fraction that is measured using a conductivity wire-mesh sensor (WMS). WMS measurements were collected in vertical upward and downward air-water flows in a pipe with an internal diameter of 32.5 mm at nearly atmospheric pressure. The relative frequencies and the power spectral density of area-averaged void fraction were calculated and used as representative properties. Independent features, extracted from these properties using Principal Component Analysis and Independent Component Analysis, were used as inputs to artificial neural networks, which were trained to give the gas and liquid flow rates as outputs. The present method was shown to be accurate for all four encountered flow regimes and for a wide range of flow conditions. Besides providing accurate predictions for steady flows, the method was also tested successfully in three flows with transient liquid flow rates. The method was augmented by the use of the cross-correlation function of area-averaged void fraction determined from the output of a dual WMS unit as an additional representative property, which was found to improve the accuracy of flow rate prediction.

  14. Performance Comparison of High-Speed Dual-Pneumatic Vitrectomy Cutters during Simulated Vitrectomy with Balanced Salt Solution.

    PubMed

    Abulon, Dina Joy K; Buboltz, David C

    2015-02-01

    To measure flow rate of balanced salt solution and IOP during simulated vitrectomy using two sets of high-speed dual-pneumatic probes. A closed-model eye system measured IOP and flow rate of a balanced salt solution through infusion cannula. The Constellation Vision System was tested with two sets of high-speed dual-pneumatic probes (UltraVit 23-gauge and enhanced 25+-gauge 5000-cpm probes; UltraVit 23-gauge and enhanced 25+-gauge 7500-cpm probes; n = 6 each) under different vacuum levels and cut rates in three duty cycle modes. In both probe sets, flow rates were dependent on cut rate with the biased open and biased closed duty cycles. Flow rates were highest with the biased open duty cycle, lower with the 50/50 duty cycle, and lowest with the biased closed duty cycle. IOP, as expected, was inversely associated with flow rate using both probe sets. The 7500-cpm probes offer greater control and customization compared with 5000-cpm probes under certain experimental conditions. At maximum cut rates, performance of 7500-cpm probes was similar to that of 5000-cpm probes, suggesting that 7500-cpm probes may be used without sacrifice of flow rate and IOP stability. Customization of vitrectomy parameters allows greater surgeon control during vitrectomy and may expand the usefulness of vitrectomy probes.

  15. Salivary protein concentration, flow rate, buffer capacity and pH estimation: A comparative study among young and elderly subjects, both normal and with gingivitis and periodontitis.

    PubMed

    Shaila, Mulki; Pai, G Prakash; Shetty, Pushparaj

    2013-01-01

    To evaluate the salivary protein concentration in gingivitis and periodontitis patients and compare the parameters like salivary total protein, salivary albumin, salivary flow rate, pH, buffer capacity and flow rate in both young and elderly patients with simple methods. One hundred and twenty subjects were grouped based on their age as young and elderly. Each group was subgrouped (20 subjects) as controls, gingivitis and periodontitis. Unstimulated whole saliva was collected from patients and flow rate was noted down during collection of the sample. Salivary protein estimation was done using the Biuret method and salivary albumin was assessed using the Bromocresol green method. pH was estimated with a pHmeter and buffering capacity was analyzed with the titration method. Student's t-test, Fisher's test (ANOVA) and Tukey HSD (ANOVA) tests were used for statistical analysis. A very highly significant rise in the salivary total protein and albumin concentration was noted in gingivitis and periodontitis subjects of both young and elderly. An overall decrease in salivary flow rate was observed among the elderly, and also the salivary flow rate of women was significantly lower than that of men. Significant associations between salivary total protein and albumin in gingivitis and periodontitis were found with simple biochemical tests. A decrease in salivary flow rate among elderly and among women was noted.

  16. Risk Factors for Reduced Salivary Flow Rate in a Japanese Population: The Hisayama Study

    PubMed Central

    Takeuchi, Kenji; Furuta, Michiko; Takeshita, Toru; Shibata, Yukie; Shimazaki, Yoshihiro; Akifusa, Sumio; Ninomiya, Toshiharu; Kiyohara, Yutaka; Yamashita, Yoshihisa

    2015-01-01

    The purpose of this study was to determine distinct risk factors causing reduced salivary flow rate in a community-dwelling population using a prospective cohort study design. This was a 5-year follow-up survey of 1,377 community-dwelling Japanese individuals aged ≥40 years. The salivary flow rate was evaluated at baseline and follow-up by collecting stimulated saliva. Data on demographic characteristics, use of medication, and general and oral health status were obtained at baseline. The relationship between reduced salivary flow rate during the follow-up period and its predictors was evaluated after adjustment for confounding factors. In a multivariate logistic regression model, higher age and plaque score and lower serum albumin levels were significantly associated with greater odds of an obvious reduction in salivary flow rate (age per decade, odds ratio [OR] = 1.25, 95% confidence interval [CI] = 1.03–1.51; serum albumin levels <4 g/dL, OR = 1.60, 95% CI = 1.04–2.46; plaque score ≥1, OR = 1.53, 95% CI = 1.04–2.24). In a multivariate linear regression model, age and plaque score remained independently associated with the increased rate of reduced salivary flow. These results suggest that aging and plaque score are important predictors of reduced salivary flow rate in Japanese adults. PMID:25705657

  17. The effect of light level, CO2 flow rate, and anesthesia on the stress response of mice during CO2 euthanasia.

    PubMed

    Powell, Karin; Ethun, Kelly; Taylor, Douglas K

    2016-09-21

    Euthanasia protocols are designed to mitigate the stress experienced by animals, and an environment that induces minimal stress helps achieve that goal. A protocol that is efficient and practical in a typical animal research facility is also important. Light intensity, isoflurane, and CO2 flow rate were studied for their impact on the stress response of mice during CO2 euthanasia. Behavior was observed and scored during euthanasia and serum corticosterone was measured immediately after death. Unsurprisingly, animals euthanized with a high-flow rate of CO2 became unconscious in the least amount of time, while animals euthanized with a low-flow rate required the most time to reach unconsciousness. There was a significant increase in anxious behaviors in animals in the isoflurane group (F1,12 = 6.67, P = 0.024), the high-flow rate CO2 group (F1,12 = 10.24, P = 0.007), and bright chamber group (F1,12 = 7.27, P = 0.019). Serum corticosterone was highest in the isoflurane group (124.72 ± 83.98 ng/ml), however there was no significant difference in corticosterone levels observed for the other study variables of light and flow-rate. A darkened chamber and low CO2 flow rates help to decrease stress experienced during CO2 euthanasia, while the use of isoflurane was observed to increase the stress response during euthanasia.

  18. Continuum modeling of rate-dependent granular flows in SPH

    DOE PAGES

    Hurley, Ryan C.; Andrade, José E.

    2016-09-13

    In this paper, we discuss a constitutive law for modeling rate-dependent granular flows that has been implemented in smoothed particle hydrodynamics (SPH). We model granular materials using a viscoplastic constitutive law that produces a Drucker–Prager-like yield condition in the limit of vanishing flow. A friction law for non-steady flows, incorporating rate-dependence and dilation, is derived and implemented within the constitutive law. We compare our SPH simulations with experimental data, demonstrating that they can capture both steady and non-steady dynamic flow behavior, notably including transient column collapse profiles. In conclusion, this technique may therefore be attractive for modeling the time-dependent evolutionmore » of natural and industrial flows.« less

  19. Effort of breathing in children receiving high-flow nasal cannula.

    PubMed

    Rubin, Sarah; Ghuman, Anoopindar; Deakers, Timothy; Khemani, Robinder; Ross, Patrick; Newth, Christopher J

    2014-01-01

    High-flow humidified nasal cannula is often used to provide noninvasive respiratory support in children. The effect of high-flow humidified nasal cannula on effort of breathing in children has not been objectively studied, and the mechanism by which respiratory support is provided remains unclear. This study uses an objective measure of effort of breathing (Pressure. Rate Product) to evaluate high-flow humidified nasal cannula in critically ill children. Prospective cohort study. Quaternary care free-standing academic children's hospital. ICU patients younger than 18 years receiving high-flow humidified nasal cannula or whom the medical team planned to extubate to high-flow humidified nasal cannula within 72 hours of enrollment. An esophageal pressure monitoring catheter was placed to measure pleural pressures via a Bicore CP-100 pulmonary mechanics monitor. Change in pleural pressure (ΔPes) and respiratory rate were measured on high-flow humidified nasal cannula at 2, 5, and 8 L/min. ΔPes and respiratory rate were multiplied to generate the Pressure.Rate Product, a well-established objective measure of effort of breathing. Baseline Pes, defined as pleural pressure at end exhalation during tidal breathing, reflected the positive pressure generated on each level of respiratory support. Twenty-five patients had measurements on high-flow humidified nasal cannula. Median age was 6.5 months (interquartile range, 1.3-15.5 mo). Median Pressure,Rate Product was lower on high-flow humidified nasal cannula 8 L/min (median, 329 cm H2O·min; interquartile range, 195-402) compared with high-flow humidified nasal cannula 5 L/min (median, 341; interquartile range, 232-475; p = 0.007) or high-flow humidified nasal cannula 2 L/min (median, 421; interquartile range, 233-621; p < 0.0001) and was lower on high-flow humidified nasal cannula 5 L/min compared with high-flow humidified nasal cannula 2 L/min (p = 0.01). Baseline Pes was higher on high-flow humidified nasal cannula 8 L/min than on high-flow humidified nasal cannula 2 L/min (p = 0.03). Increasing flow rates of high-flow humidified nasal cannula decreased effort of breathing in children, with the most significant impact seen from high-flow humidified nasal cannula 2 to 8 L/min. There are likely multiple mechanisms for this clinical effect, including generation of positive pressure and washout of airway dead space.

  20. 3D modeling and characterization of a calorimetric flow rate sensor for sweat rate sensing applications

    NASA Astrophysics Data System (ADS)

    Iftekhar, Ahmed Tashfin; Ho, Jenny Che-Ting; Mellinger, Axel; Kaya, Tolga

    2017-03-01

    Sweat-based physiological monitoring has been intensively explored in the last decade with the hopes of developing real-time hydration monitoring devices. Although the content of sweat (electrolytes, lactate, urea, etc.) provides significant information about the physiology, it is also very important to know the rate of sweat at the time of sweat content measurements because the sweat rate is known to alter the concentrations of sweat compounds. We developed a calorimetric based flow rate sensor using PolydimethylSiloxane that is suitable for sweat rate applications. Our simple approach on using temperature-based flow rate detection can easily be adapted to multiple sweat collection and analysis devices. Moreover, we have developed a 3D finite element analysis model of the device using COMSOL Multiphysics™ and verified the flow rate measurements. The experiment investigated flow rate values from 0.3 μl/min up to 2.1 ml/min, which covers the human sweat rate range (0.5 μl/min-10 μl/min). The 3D model simulations and analytical model calculations covered an even wider range in order to understand the main physical mechanisms of the device. With a verified 3D model, different environmental heat conditions could be further studied to shed light on the physiology of the sweat rate.

  1. Slugging Flow of Water Draining from the Bottom of a Non-Vented Container

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Charles W. Solbrig

    2010-06-01

    Experiments were run to observe the behavior of water exiting through an orifice at the bottom of an non-vented container. Initially, the container is nearly full of water with a small air space on top. Once the orifice was uncovered, the slugging rate and the drain rate of the water leaving the container were measured. Upon initially opening the orifice, water drains out until the air pressure above the water reduces enough that the air pressure drop from inside to outside of the container supports the water column and the water stops flowing. Air then enters the container through themore » orifice forming a bubble, which grows until it detaches and bubbles through the water to reach the air space. Once the bubble enters, this added air increases the pressure in the air space enough to allow the water to start flowing out again. This cycle of flow out, flow stoppage, air inflow, and bubble breakoff continues over and over until the hole is closed or the container empties. This is referred to as the “slugging cycle.” A mechanism is proposed to describe the slugging cycle which is modeled analytically. This paper presents the description of the experiments, data obtained, the mechanistic model, and comparison of the model to the experimental data. The model predicts outflow rates close to experimental values. Flow rates from non-vented containers are more than 10 to 20 less than vented containers. The bubbles which must enter the container periodically to increase the internal air pressure stop the water flow momentarily so are responsible for this large decrease in flow rate. Swirl induced in the non-vented container causes the flow rates to increase by a factor of two. The flow rate out of a non-vented container is independent of water height which is in direct contrast to a vented container where the flow rate is proportional to the square root of the water height. The constant rate is due to the container pressure. The higher the water level, the lower the air pressure is in the container. This analytical model requires input of the bubble size. The volume recommended is the volume of a cylinder with the base of the orifice area and length of 3.3 cm. Slugging rate varies only a small amount falling in the range to 2 to 4 cycles/sec. Preliminary work with other containers indicates larger containers, larger orifices and nozzle exit shapes produce higher specific flow rates. The standard multiphase flow equations could not be used to analyze this situation because the two phases are not interpenetrating. Instead one phase must fully stop before the other can flow. Interpenetrating phases allow can pass one another each affecting the other with friction and virtual mass. An interesting observation: The negative air pressure in the container is observable. It equals the water height.« less

  2. Comparison of Flow Characteristics of Novel Three-Dimensional Printed Ureteral Stents Versus Standard Ureteral Stents in a Porcine Model.

    PubMed

    Del Junco, Michael; Yoon, Renai; Okhunov, Zhamshid; Abedi, Garen; Hwang, Christina; Dolan, Benjamin; Landman, Jaime

    2015-09-01

    We compared the flow characteristics of novel three-dimensional (3D) printed ureteral stents with four conventional double-pigtail stents in an ex vivo porcine model. In six ex vivo porcine urinary systems with kidneys and ureters intact, we deployed a 5F occlusion catheter in an interpolar calix. We tested each system with antegrade irrigation with a 0.9% saline bag placed 35 cm above the renal pelvis. We evaluated four standard stents (6F Universa® Soft, 7F Percuflex,™ 7/10F Applied Endopyelotomy, 8.5F Filiform Double Pigtail) and compared them with a 9F 3D printed prototype stent. For each stent, we measured the total, extraluminal, and intraluminal flow rates. The mean total flow rates for 3D printed stents were significantly higher than the 6F, 7F, and 7/10F stents (P<0.05). No significant difference was seen in the total flow rate for the 3D printed stent and the 8.5F stent. The mean extraluminal flow rates for the 3D stents were similar to those of 7F stents, but significantly lower than 6F stents (P<0.001) and 8.5F stents (P<0.05) and higher than 7/10F stents (P<0.001). The mean intraluminal flow rates for the 3D printed stents were significantly higher than the 6F, 7F, 7/10F, and 8.5F stents (P<0.05). In this pilot study, 3D printed stents manifested a mean total flow rate comparable to the flow rates of contemporary stents. Continued advances in technology and material may permit functionally feasible 3D printed ureteral stents.

  3. 10 CFR 431.264 - Uniform test method for the measurement of flow rate for commercial prerinse spray valves.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ..., the water consumption flow rate of commercial prerinse spray valves. (b) Testing and Calculations. The test procedure to determine the water consumption flow rate for prerinse spray valves, expressed in... the previous step. Round the final water consumption value to one decimal place as follows: (1) A...

  4. MOLA Topographic Constraints on Lava Tube Effusion Rates for Alba Patera, Mars

    NASA Technical Reports Server (NTRS)

    Riedel, S. J.; Sakimoto, S. E. H.

    2002-01-01

    Using high resolution MOLA (Mars Orbiter Laser Altimeter) topographic data to accurately model flow rates, we find that Alba Patera tube-fed flows within the mid to lower flanks could accommodate flow rates between 10 Pa s to 1.308 x 10(exp 6) Pa s. Additional information is contained in the original extended abstract.

  5. Formation flow rate control method in multi-layer production

    NASA Astrophysics Data System (ADS)

    Muzipov, H. N.; Akhmadulin, R. К; Bakanovskaya, L. N.

    2018-05-01

    The article describes a method of flow rate control of separate formations in multilayer production by noises frequency response (FR). The noise FR is converted into electrical signals scaled in proportion to the flow rates using secondary facilities. The pump noise is suggested to be reduced with the quarter-wave acoustic resonator working as an acoustic filter.

  6. [Xerostomia, hyposialia, sicca syndrome--quantitative disturbances of the salivary flow rate].

    PubMed

    Slezák, R; Berglová, I; Krejsek, J

    2011-04-01

    Diseases of salivary glands may be associated with salivary flow rate disturbances. Production of the saliva is evaluated by sialometric tests. The stress is putted on salivary flow rate disturbances in Sjögren's syndrome, drug-induced and postirradiative sialopathy, and diabetes mellitus. The possibility of the stimulation and substitution of the saliva is discussed.

  7. Rapid microfluidic mixing.

    PubMed

    Johnson, Timothy J; Ross, David; Locascio, Laurie E

    2002-01-01

    A preformed T-microchannel imprinted in polycarbonate was postmodified with a pulsed UV excimer laser (KrF, 248 nm) to create a series of slanted wells at the junction. The presence of the wells leads to a high degree of lateral transport within the channel and rapid mixing of two confluent streams undergoing electroosmotic flow. Several mixer designs were fabricated and investigated. All designs were relatively successful at low flow rates (0.06 cm/s, > or = 75% mixing), but had varying degrees of success at high flow rates (0.81 cm/s, 45-80% mixing). For example, one design operating at high flow rates was able to split an incoming fluorescent stream into two streams of varying concentrations depending on the number of slanted wells present. The final mixer design was able to overcome stream splitting at high flow rates, and it was shown that the two incoming streams were 80% mixed within 443 microm of the T-junction for a flow rate of 0.81 cm/s. Without the presence of the mixer and at the same high flow rate, a channel length of 2.3 cm would be required to achieve the same extent of mixing when relying upon molecular diffusion entirely, while 6.9 cm would be required for 99% mixing.

  8. Diffusion-limited mixing by incompressible flows

    NASA Astrophysics Data System (ADS)

    Miles, Christopher J.; Doering, Charles R.

    2018-05-01

    Incompressible flows can be effective mixers by appropriately advecting a passive tracer to produce small filamentation length scales. In addition, diffusion is generally perceived as beneficial to mixing due to its ability to homogenize a passive tracer. However we provide numerical evidence that, in cases where advection and diffusion are both actively present, diffusion may produce negative effects by limiting the mixing effectiveness of incompressible optimal flows. This limitation appears to be due to the presence of a limiting length scale given by a generalised Batchelor length (Batchelor 1959 J. Fluid Mech. 5 113–33). This length scale limitation may in turn affect long-term mixing rates. More specifically, we consider local-in-time flow optimisation under energy and enstrophy flow constraints with the objective of maximising the mixing rate. We observe that, for enstrophy-bounded optimal flows, the strength of diffusion may not impact the long-term mixing rate. For energy-constrained optimal flows, however, an increase in the strength of diffusion can decrease the mixing rate. We provide analytical lower bounds on mixing rates and length scales achievable under related constraints (point-wise bounded speed and rate-of-strain) by extending the work of Lin et al (2011 J. Fluid Mech. 675 465–76) and Poon (1996 Commun. PDE 21 521–39).

  9. Pressure-flow reducer for aerosol focusing devices

    DOEpatents

    Gard, Eric; Riot, Vincent; Coffee, Keith; Woods, Bruce; Tobias, Herbert; Birch, Jim; Weisgraber, Todd

    2008-04-22

    A pressure-flow reducer, and an aerosol focusing system incorporating such a pressure-flow reducer, for performing high-flow, atmosphere-pressure sampling while delivering a tightly focused particle beam in vacuum via an aerodynamic focusing lens stack. The pressure-flow reducer has an inlet nozzle for adjusting the sampling flow rate, a pressure-flow reduction region with a skimmer and pumping ports for reducing the pressure and flow to enable interfacing with low pressure, low flow aerosol focusing devices, and a relaxation chamber for slowing or stopping aerosol particles. In this manner, the pressure-flow reducer decouples pressure from flow, and enables aerosol sampling at atmospheric pressure and at rates greater than 1 liter per minute.

  10. A simple analytical model of coupled single flow channel over porous electrode in vanadium redox flow battery with serpentine flow channel

    NASA Astrophysics Data System (ADS)

    Ke, Xinyou; Alexander, J. Iwan D.; Prahl, Joseph M.; Savinell, Robert F.

    2015-08-01

    A simple analytical model of a layered system comprised of a single passage of a serpentine flow channel and a parallel underlying porous electrode (or porous layer) is proposed. This analytical model is derived from Navier-Stokes motion in the flow channel and Darcy-Brinkman model in the porous layer. The continuities of flow velocity and normal stress are applied at the interface between the flow channel and the porous layer. The effects of the inlet volumetric flow rate, thickness of the flow channel and thickness of a typical carbon fiber paper porous layer on the volumetric flow rate within this porous layer are studied. The maximum current density based on the electrolyte volumetric flow rate is predicted, and found to be consistent with reported numerical simulation. It is found that, for a mean inlet flow velocity of 33.3 cm s-1, the analytical maximum current density is estimated to be 377 mA cm-2, which compares favorably with experimental result reported by others of ∼400 mA cm-2.

  11. Drop size distribution and air velocity measurements in air assist swirl atomizer sprays

    NASA Technical Reports Server (NTRS)

    Mao, C.-P.; Oechsle, V.; Chigier, N.

    1987-01-01

    Detailed measurements of mean drop size (SMD) and size distribution parameters have been made using a Fraunhofer diffraction particle sizing instrument in a series of sprays generated by an air assist swirl atomizer. Thirty-six different combinations of fuel and air mass flow rates were examined with liquid flow rates up to 14 lbm/hr and atomizing air flow rates up to 10 lbm/hr. Linear relationships were found between SMD and liquid to air mass flow rate ratios. SMD increased with distance downstream along the center line and also with radial distance from the axis. Increase in obscuration with distance downstream was due to an increase in number density of particles as the result of deceleration of drops and an increase in the exposed path length of the laser beam. Velocity components of the atomizing air flow field measured by a laser anemometer show swirling jet air flow fields with solid body rotation in the core and free vortex flow in the outer regions.

  12. Construction and geometric stability of physiological flow rate wall-less stenosis phantoms.

    PubMed

    Ramnarine, K V; Anderson, T; Hoskins, P R

    2001-02-01

    Wall-less flow phantoms are preferred for ultrasound (US) because tissue-mimicking material (TMM) with good acoustical properties can be made and cast to form anatomical models. The construction and geometrical stability of wall-less TMM flow phantoms is described using a novel method of sealing to prevent leakage of the blood-mimicking fluid (BMF). Wall-less stenosis flow models were constructed using a robust agar-based TMM and sealed using reticulated foam at the inlet and outlet tubes. There was no BMF leakage at the highest flow rate of 2.8 L/min in 0%, 35% and 57% diameter reduction stenoses models. Failure of the 75% stenosis model, due to TMM fracture, occurred at maximum flow rate of 2 L/min (mean velocity 10 m/s within the stenosis). No change of stenosis geometry was measured over 4 days. The construction is simple and effective and extends the possibility for high flow rate studies using robust TMM wall-less phantoms.

  13. Comparison of cutting efficiency with different diamond burs and water flow rates in cutting lithium disilicate glass ceramic.

    PubMed

    Siegel, Sharon C; Patel, Tejas

    2016-10-01

    This study compared different diamond burs and different water flow rates on the cutting efficiency of sectioning through lithium disilicate glass ceramic. The authors used a standardized cutting regimen with 4 brands of diamond burs to section through lithium disilicate glass ceramic blocks. Twelve diamonds of each brand cut through the blocks in randomized order. In the first part of the study, the authors recorded sectioning rates in millimeters per minute for each diamond bur as a measure of cutting efficiency. In the second part of the study, the authors compared sectioning rates using only 1 brand of diamond bur, with 3 different water flow rates. The authors averaged and compared cutting rates of each brand of diamond bur and the cutting rates for each flow rate using an analysis of variance and determined the differences with a Tukey honest significant difference test. One diamond bur cut significantly slower than the other 3, and one diamond bur cut significantly faster than 2 of the others. The diamond bur cutting efficiency through lithium disilicate glass ceramic with a 20 mL/min water flow rate was significantly higher than 15 mL/min. There are differences in cutting efficiency between diamond burs when sectioning lithium disilicate glass ceramic. Use a minimum of 20 mL/min of water coolant flow when sectioning lithium disilicate glass ceramic with dental diamond burs to maximize cutting efficiency. Recommendations for specific diamond burs with a coarse grit and water flow rate of 20 mL/min can be made when removing or adjusting restorations made from lithium disilicate glass ceramic. Copyright © 2016 American Dental Association. Published by Elsevier Inc. All rights reserved.

  14. Safety and Efficacy of Occlusion of Large Extra-Prostatic Anastomoses During Prostatic Artery Embolization for Symptomatic BPH

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Amouyal, Gregory, E-mail: gregamouyal@hotmail.com; Chague, Pierre, E-mail: pierre.chague@gmail.com; Pellerin, Olivier, E-mail: olivier.pellerin@aphp.fr

    IntroductionDuring PAE, preembolization angiography of the prostatic artery can show large extra-prostatic shunts, at high risk, if embolized, of rectal or penile necrosis. We report our experience with 11 consecutive patients who underwent protective embolization of large extra-prostatic shunts before successful PAE.Materials and MethodsWe treated 11 consecutive male patients (mean age 67 years), part of a series of 55 consecutive male patients referred for PAE to treat LUTS due to BPH, between December 2013 and January 2015. The procedure involved the exclusion of an extra-prostatic shunt originating from the PA, prior to complete bilateral PAE. We compared the safety and efficacymore » of the 11 shunt exclusions followed by embolization of the PA to the other 44 basic PAE. Clinical success was defined as a decrease of 25 % or eight points of IPSS, QoL <3 or a one-point decrease, and a Qmax improvement of 25 % or 2.5 mL/s.ResultsWe had a 100 % rate of occlusion of the anastomosis. Bilateral embolization of the PA was performed in all patients with no additional time of procedure (p = 0.18), but a significant increase of dose area product (p = 0.03). Distal (PErFecTED) embolization was possible in 64 %. There was no worsening of erectile dysfunction, no rectal or penile necrosis, no immediate or late other clinical complications. Clinical success was 91 % (mean follow-up: 3.5 months), compared to 78 % for the entire PAE group.ConclusionPAE using the protection technique in case of large extra-prostatic shunts is as safe and effective as basic procedures and does not induce any additional time of procedure.« less

  15. Adsorption Mechanisms of Dodecylbenzene Sulfonic Acid by Corn Straw and Poplar Leaf Biochars

    PubMed Central

    Zhao, Nan; Yang, Xixiang; Zhang, Jing; Zhu, Ling; Lv, Yizhong

    2017-01-01

    Biochar is an eco-friendly, renewable, and cost-effective material that can be used as an adsorbent for the remediation of contaminated environments. In this paper, two types of biochar were prepared through corn straw and poplar leaf pyrolysis at 300 °C and 700 °C (C300, C700, P300, P700). Brunaer–Emmett–Teller N2 surface area, scanning electron microscope, elemental analysis, and infrared spectra were used to characterize their structures. These biochars were then used as adsorbents for the adsorption of dodecylbenzene sulfonic acid (DBSA). The microscopic adsorption mechanisms were studied by using infrared spectra, 13C-nuclear magnetic resonance spectra, and electron spin resonance spectra. The surface area and pore volume of C700 (375.89 m2/g and 0.2302 cm3/g) were the highest among all samples. Elemental analysis results showed that corn straw biochars had a higher aromaticity and carbon to nitrogen (C/N) ratio than the poplar leaf biochars. High temperature caused the increase of carbon content and the decrease of oxygen content, which also gave the biochars a higher adsorption rate. Pseudo-second order kinetic provided a better fit with the experimental data. Adsorption isotherm experiments showed that the adsorption isotherm of C300 fit the linear model. For other biochars, the adsorption isotherms fitted Langmuir model. Biochars with high temperatures exhibited enhanced adsorption capacity compared with ones at low temperatures. The qmax values of biochars to DBSA followed the order of P700 > C700 > P300. The adsorption mechanisms were complex, including partition, anion exchange, the formation of H bonds, covalent bonds, and charge transfer. The adsorption by covalent bonding might be the key mechanism determining the adsorption capacity of P700. PMID:28937637

  16. Highly active nanoscale zero-valent iron (nZVI)-Fe3O4 nanocomposites for the removal of chromium(VI) from aqueous solutions.

    PubMed

    Lv, Xiaoshu; Xu, Jiang; Jiang, Guangming; Tang, Jie; Xu, Xinhua

    2012-03-01

    For the first time, nanoscale zero-valent iron (nZVI)-Fe(3)O(4) nanocomposites, prepared by an in situ reduction method, are employed for chromium(VI) removal in aqueous environment. 96.4% Cr(VI) could be removed by these novel materials within 2h under pH of 8.0 and initial Cr concentration of 20 mg L(-1), compared with 48.8% by bare nFe(3)O(4) and 18.8% by bare nZVI. Effects of several factors, including mass composition of nZVI-Fe(3)O(4) nanocomposites, initial pH and Cr(VI) concentration, were evaluated. The optimal ratio of nFe(3)O(4) to nZVI mass lies at 12:1 with a fixed nZVI concentration of 0.05 g L(-1). Low pH and initial Cr(VI) concentration could increase both the Cr(VI) removal efficiency and reaction rate. Corresponding reaction kinetics fitted well with the pseudo second-order adsorption model. Free energy change (ΔG) of this reaction was calculated to be -4.6 kJ mol(-1) by thermodynamic study, which confirmed its spontaneous and endothermic characteristic. The experimental data could be well described by the Langmuir and Freundlich model, and the maximum capacity (q(max)) obtained from the Langmuir model was 100 and 29.43 mg g(-1) at pH 3.0 and 8.0, respectively. The reaction mechanism was discussed in terms of the mutual benefit brought by the electron transfer from Fe(0) to Fe(3)O(4). Copyright © 2011 Elsevier Inc. All rights reserved.

  17. Holmium laser vs. conventional (cold knife) direct visual internal urethrotomy for short-segment bulbar urethral stricture: Outcome analysis.

    PubMed

    Jhanwar, Ankur; Kumar, Manoj; Sankhwar, Satya Narayan; Prakash, Gaurav

    2016-01-01

    Our goal was to analyze the outcome between holmium laser and cold knife direct visual internal urethrotomy (DVIU) for short-segment bulbar urethral stricture. We conducted a prospective study comprised of 112 male patients seen from June 2013 to December 2014. Inclusion criterion was short-segment bulbar urethral stricture (≤1.5cm). Exclusion criteria were prior intervention/urethroplasty, pan-anterior urethral strictures, posterior stenosis, urinary tract infection, and those who lost to followup. Patients were divided into two groups; Group A (n=58) included cold knife DVIU and group B (n=54) included holmium laser endourethrotomy patients. Patient followup included uroflowmetry at postoperative Day 3, as well as at three months and six months. Baseline demographics were comparable in both groups. A total of 107 patients met the inclusion criteria and five patients were excluded due to inadequate followup. Mean stricture length was 1.31 ± 0.252 cm (p=0.53) and 1.34 ± 0.251 cm in Groups A and B, respectively. Mean operating time in Group A was 16.3 ± 1.78 min and in Group B was 20.96 ± 2.23 min (p=0.0001). Five patients in Group A had bleeding after the procedure that was managed conservatively by applying perineal compression. Three patients in Group B had fluid extravasation postoperatively. Qmax (ml/s) was found to be statistically insignificant between the two groups at all followups. Both holmium laser and cold knife urethrotomy are safe and equally effective in treating short-segment bulbar urethral strictures in terms of outcome and complication rate. However, holmium laser requires more expertise and is a costly alternative.

  18. A novel highly efficient adsorbent {[Co4(L)2(μ3-OH)2(H2O)3(4,4‧-bipy)2]·(H2O)2}n: Synthesis, crystal structure, magnetic and arsenic (V) absorption capacity

    NASA Astrophysics Data System (ADS)

    Zhang, Chong; Xiao, Yu; Qin, Yan; Sun, Quanchun; Zhang, Shuhua

    2018-05-01

    A novel highly efficient adsorbent-microporous tetranuclear Co(II)-based polymer, {[Co4(L)2(μ3-OH)2(H2O)3(4,4‧-bipy)2]·(H2O)2}n (1, H3L = 4-(N,N‧-bis(4-carboxybenzyl)amino) benzenesulfonic acid, 4,4‧-bipy = 4,4‧-bipyridine), was hydrothermally synthesized. The complex 1 is a metal-organic framework (MOF) material which was characterized by single-crystal X-ray diffraction, BET and platon software. Co-MOF (complex 1) reveals excellent adsorption property. The capacity of Co-MOF to remove arsenic As(V) from sodium arsenate aqueous solutions was investigated (The form of As(V) is AsO43-). The experimental results showed that Co-MOF had a higher stable and relatively high As(V) removal rate (> 98%) at pH 4-10. The adsorption kinetics followed a pseudo-second-order kinetic model, and the adsorption isotherm followed the Langmuir equation. Co-MOF exhibits a very high adsorption capacity of As(V) in aqueous solution (Qmax of 96.08 mg/g). Finally, the optimal adsorption conditions for the model were obtained through a Box-Behnken response surface experiment which was designed with adsorption time, dose, temperature and rotational speed of the shaker as the influencing factors to determine two-factor interaction effects. Co-MOF was further characterized using FTIR, PXRD, X-ray photoelectron spectroscopy before and after adsorption As (V). The magnetism of Co-MOF was also discussed.

  19. Preparation of molecularly imprinted solid-phase microextraction fiber for the selective removal and extraction of the antiviral drug abacavir in environmental and biological matrices.

    PubMed

    Terzopoulou, Zoi; Papageorgiou, Myrsini; Kyzas, George Z; Bikiaris, Dimitrios N; Lambropoulou, Dimitra A

    2016-03-24

    In the present study, a molecularly imprinted solid-phase microextraction fiber (MIP-SPMEf) was synthesized and applied for the selective removal and extraction of the antiviral drug, abacavir (ABA). Morphology and structure characterization of fibers were performed by scanning electron microscopy and Fourier transform infrared spectra, respectively. The effects on the adsorption behavior of the process parameters were studied and the equilibrium data were fitted by the Langmuir, Freundlich and Langmuir-Freundlich models. The maximum adsorption capability (Qmax) was determined by Langmuir- Freundlich model and was 149 mg/g for MIP-SPMEf. In the next step, SPME methodology followed by liquid desorption and liquid chromatography with mass spectrometry (LC/MS) has been developed and evaluated for the determination of the target compound in environmental and biological matrices (surface waters, wastewaters and urine). Parameters that could influence SPME efficiency were investigated. Then, optimization of stirring speed, extraction time and salt content was carried out by using a central composite design (CCD) and response surface methodology (RSM). A quadratic model between dependent and independent variables was built. Under the optimum conditions (extraction time 40 min, stirring rate 650 rpm and salt content 0.3% NaCl w/v) the validated method presented a high sensitivity and selectivity with LODs and LOQs in the range of 10.1-13.6 and 33.3-43.9 ng/L, respectively. The developed method was successfully applied to the analysis of ABA in real samples. The percentage extraction efficiency ranged from 88 to 99% revealing good accuracy and absence of matrix effects. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Clinical Results After Prostatic Artery Embolization Using the PErFecTED Technique: A Single-Center Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Amouyal, Gregory, E-mail: gregamouyal@hotmail.com; Thiounn, Nicolas, E-mail: nicolas.thiounn@aphp.fr; Pellerin, Olivier, E-mail: olivier.pellerin@aphp.fr

    BackgroundProstatic artery embolization (PAE) has been performed for a few years, but there is no report on PAE using the PErFecTED technique outside from the team that initiated this approach.ObjectiveThis single-center retrospective open label study reports our experience and clinical results on patients suffering from symptomatic BPH, who underwent PAE aiming at using the PErFecTED technique.Materials and MethodsWe treated 32 consecutive patients, mean age 65 (52–84 years old) between December 2013 and January 2015. Patients were referred for PAE after failure of medical treatment and refusal or contra-indication to surgery. They were treated using the PErFecTED technique, when feasible, with 300–500 µmmore » calibrated microspheres (two-night hospital stay or outpatient procedure). Follow-up was performed at 3, 6, and 12 months.ResultsWe had a 100 % immediate technical success of embolization (68 % of feasibility of the PErFecTED technique) with no immediate complications. After a mean follow-up of 7.7 months, we observed a 78 % rate of clinical success. Mean IPSS decreased from 15.3 to 4.2 (p = .03), mean QoL from 5.4 to 2 (p = .03), mean Qmax increased from 9.2 to 19.2 (p = .25), mean prostatic volume decreased from 91 to 62 (p = .009) mL. There was no retrograde ejaculation and no major complication.ConclusionPAE using the PErFecTED technique is a safe and efficient technique to treat bothersome LUTS related to BPH. It is of interest to note that the PErFecTED technique cannot be performed in some cases for anatomical reasons.« less

  1. 40 CFR 1065.245 - Sample flow meter for batch sampling.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... rates or total flow sampled into a batch sampling system over a test interval. You may use the... rates or total raw exhaust flow over a test interval. (b) Component requirements. We recommend that you... averaging Pitot tube, or a hot-wire anemometer. Note that your overall system for measuring sample flow must...

  2. Effect of Er,Cr:YSGG laser on human dentin fluid flow.

    PubMed

    Al-Omari, Wael M; Palamara, Joseph E

    2013-11-01

    The aim of the current investigation was to assess the rate and magnitude of dentin fluid flow of dentinal surfaces irradiated with Er,Cr:YSGG laser. Twenty extracted third molars were sectioned, mounted, and irradiated with Er,Cr:YSGG laser at 3.5 and 4.5 W power settings. Specimens were connected to an automated fluid flow measurement apparatus (Flodec). The rate, magnitude, and direction of dentin fluid flow were recorded at baseline and after irradiation. Nonparametric Wilcoxon signed ranks repeated measure t test revealed a statistically significant reduction in fluid flow for all the power settings. The 4.5-W power output reduced the flow significantly more than the 3.5 W. The samples showed a baseline outward flow followed by inward flow due to irradiation then followed by decreased outward flow. It was concluded that Er,Cr:YSGG laser irradiation at 3.5 and 4.5 W significantly reduced dentinal fluid flow rate. The reduction was directly proportional to power output.

  3. Numerical study of Tallinn storm-water system flooding conditions using CFD simulations of multi-phase flow in a large-scale inverted siphon

    NASA Astrophysics Data System (ADS)

    Kaur, K.; Laanearu, J.; Annus, I.

    2017-10-01

    The numerical experiments are carried out for qualitative and quantitative interpretation of a multi-phase flow processes associated with malfunctioning of the Tallinn storm-water system during rain storms. The investigations are focused on the single-line inverted siphon, which is used as under-road connection of pipes of the storm-water system under interest. A multi-phase flow solver of Computational Fluid Dynamics software OpenFOAM is used for simulating the three-phase flow dynamics in the hydraulic system. The CFD simulations are performed with different inflow rates under same initial conditions. The computational results are compared essentially in two cases 1) design flow rate and 2) larger flow rate, for emptying the initially filled inverted siphon from a slurry-fluid. The larger flow-rate situations are under particular interest to detected possible flooding. In this regard, it is anticipated that the CFD solutions provide an important insight to functioning of inverted siphon under a restricted water-flow conditions at simultaneous presence of air and slurry-fluid.

  4. Groundwater remediation engineering sparging using acetylene--study on the flow distribution of air.

    PubMed

    Zheng, Yan-Mei; Zhang, Ying; Huang, Guo-Qiang; Jiang, Bin; Li, Xin-Gang

    2005-01-01

    Air sparging (AS) is an emerging method to remove VOCs from saturated soils and groundwater. Air sparging performance highly depends on the air distribution resulting in the aquifer. In order to study gas flow characterization, a two-dimensional experimental chamber was designed and installed. In addition, the method by using acetylene as the tracer to directly image the gas distribution results of AS process has been put forward. Experiments were performed with different injected gas flow rates. The gas flow patterns were found to depend significantly on the injected gas flow rate, and the characterization of gas flow distributions in porous media was very different from the acetylene tracing study. Lower and higher gas flow rates generally yield more irregular in shape and less effective gas distributions.

  5. Flow rate and temperature characteristics in steady state condition on FASSIP-01 loop during commissioning

    NASA Astrophysics Data System (ADS)

    Juarsa, M.; Giarno; Rohman, A. N.; Heru K., G. B.; Witoko, J. P.; Sony Tjahyani, D. T.

    2018-02-01

    The need for large-scale experimental facilities to investigate the phenomenon of natural circulation flow rate becomes a necessity in the development of nuclear reactor safety management. The FASSIP-01 loop has been built to determine the natural circulation flow rate performance in the large-scale media and aimed to reduce errors in the results for its application in the design of new generation reactors. The commissioning needs to be done to define the capability of the FASSIP-01 loop and to prescribe the experiment limitations. On this commissioning, two scenarios experimental method has been used. The first scenario is a static condition test which was conducted to verify measurement system response during 24 hours without electrical load in heater and cooler, there is water and no water inside the rectangular loop. Second scenario is a dynamics condition that aims to understand the flow rate, a dynamic test was conducted using heater power of 5627 watts and coolant flow rate in the HSS loop of 9.35 LPM. The result of this test shows that the temperature characterization on static test provide a recommendation, that the experiments should be done at night because has a better environmental temperature stability compared to afternoon, with stable temperature around 1°C - 3°C. While on the dynamic test, the water temperature difference between the inlet-outlets in the heater area is quite large, about 7 times the temperature difference in the cooler area. The magnitude of the natural circulation flow rate calculated is much larger at about 300 times compared to the measured flow rate with different flow rate profiles.

  6. Relationship between unstimulated salivary flow rate and saliva composition of healthy children in Taiwan.

    PubMed

    Wu, Katie P; Ke, Jyh-Yuh; Chung, Chia-Ying; Chen, Chia-Ling; Hwang, Tsong-Long; Chou, Ming-Yen; Wong, Alice M K; Hu, Ching-Fang; Lee, Yu-Cheng

    2008-01-01

    Saliva is one of the most important factors in regulating oral health, with flow rate and composition changing throughout development and during disease. In view of the shortage of data, the present study aimed to shed light on the relationship between unstimulated salivary flow rate and saliva composition of healthy children in Taiwan. Forty-four normal, healthy children from 3-14 years of age were divided into three age groups: pre-school, elementary school and junior-high school. All participants received salivary flow rate, pH and saliva composition analysis under unstimulated conditions. One-way ANOVA and Pearson's correlation were used. Statistical significance was set at p < 0.05. Our results suggest that, under unstimulated conditions, the salivary flow rate of the elementary school group was greater than that of the pre-school group (p < 0.05). No difference in pH was found among the three groups. Intergroup salivary calcium, phosphorus and amylase did not reach statistical difference. As the flow rate increased, the pH increased (r = 0.364, p < 0.05) but the protein level decreased (r = -0.473, p < 0.05). In addition, salivary protein was positively correlated to age (r = 0.479, p < 0.05) and negatively correlated to pH (r = -0.361, p < 0.01). Age-related increase in the unstimulated salivary flow rate of pre-school and elementary school groups was noted. As the flow rate increased, the pH increased but the protein level decreased. The information obtained may serve as reference values for the growing interest in saliva as a diagnostic tool, especially monitoring those with neurological or oral motor dysfunction.

  7. Automatic tracer-dilution method used for stage-discharge ratings and streamflow hydrographs on small Iowa streams

    USGS Publications Warehouse

    Soenksen, P.J.

    1990-01-01

    Tracer-dilution discharge measurements were made during 14 flow periods at six stations from 1986 through 1988 water years. Ratings were developed at three stations with the aid of these measurements. A loop rating was identified at one station during rapidly-changing flow conditions. Incomplete mixing and dye loss to sediment apparently were problems at some stations. Stage hydrographs were recorded for 38 flows at seven stations. Limited data on background fluorescence during high flows were also obtained.

  8. Optical measurement of high-temperature melt flow rate.

    PubMed

    Bizjan, Benjamin; Širok, Brane; Chen, Jinpeng

    2018-05-20

    This paper presents an optical method and system for contactless measurement of the mass flow rate of melts by digital cameras. The proposed method is based on reconstruction of melt stream geometry and flow velocity calculation by cross correlation, and is very cost-effective due its modest hardware requirements. Using a laboratory test rig with a small inductive melting pot and reference mass flow rate measurement by weighing, the proposed method was demonstrated to have an excellent dynamic response (0.1 s order of magnitude) while producing deviations from the reference of about 5% in the steady-state flow regime. Similar results were obtained in an industrial stone wool production line for two repeated measurements. Our method was tested in a wide range of melt flow rates (0.05-1.2 kg/s) and did not require very fast cameras (120 frames per second would be sufficient for most industrial applications).

  9. Power flow controller with a fractionally rated back-to-back converter

    DOEpatents

    Divan, Deepakraj M.; Kandula, Rajendra Prasad; Prasai, Anish

    2016-03-08

    A power flow controller with a fractionally rated back-to-back (BTB) converter is provided. The power flow controller provide dynamic control of both active and reactive power of a power system. The power flow controller inserts a voltage with controllable magnitude and phase between two AC sources at the same frequency; thereby effecting control of active and reactive power flows between the two AC sources. A transformer may be augmented with a fractionally rated bi-directional Back to Back (BTB) converter. The fractionally rated BTB converter comprises a transformer side converter (TSC), a direct-current (DC) link, and a line side converter (LSC). By controlling the switches of the BTB converter, the effective phase angle between the two AC source voltages may be regulated, and the amplitude of the voltage inserted by the power flow controller may be adjusted with respect to the AC source voltages.

  10. Survival of Poliovirus in Flowing Turbid Seawater Treated with Ultraviolet Light

    PubMed Central

    Hill, W. F.; Hamblet, F. E.; Akin, E. W.

    1967-01-01

    The effectiveness of a model ultraviolet (UV) radiation unit for treating flowing turbid seawater contaminated with poliovirus was determined. At a turbidity of 70 ppm, the observed survival ratios ranged from 1.9 × 10-3 (99.81% reduction) to 1.5 × 10-4 (99.98% reduction) at flow rates ranging from 25 to 15 liters/min; no virus was recovered at flow rates of 10 and 5 liters/min. At a turbidity of 240 ppm, the observed survival ratios ranged from 3.2 × 10-2 (96.80% reduction) to 2.1 × 10-4 (99.98% reduction) at flow rates ranging from 25 to 5 liters/min. As expected, turbidity had an adverse influence on the effectiveness of UV radiation; however, by adjusting the flow rate of the seawater through the treatment unit, adequate disinfection was shown to be predictable. Images Fig. 1 PMID:4291955

  11. Phase transition and flow-rate behavior of merging granular flows.

    PubMed

    Hu, Mao-Bin; Liu, Qi-Yi; Jiang, Rui; Hou, Meiying; Wu, Qing-Song

    2015-02-01

    Merging of granular flows is ubiquitous in industrial, mining, and geological processes. However, its behavior remains poorly understood. This paper studies the phase transition and flow-rate behavior of two granular flows merging into one channel. When the main channel is wider than the side channel, the system shows a remarkable two-sudden-drops phenomenon in the outflow rate when gradually increasing the main inflow. When gradually decreasing the main inflow, the system shows obvious hysteresis phenomenon. We study the flow-rate-drop phenomenon by measuring the area fraction and the mean velocity at the merging point. The phase diagram of the system is also presented to understand the occurrence of the phenomenon. We find that the dilute-to-dense transition occurs when the area fraction of particles at the joint point exceeds a critical value ϕ(c)=0.65±0.03.

  12. Channel overflows of the Pōhue Bay flow, Mauna Loa, Hawai'i: examples of the contrast between surface and interior lava

    NASA Astrophysics Data System (ADS)

    Jurado-Chichay, Zinzuni; Rowland, Scott K.

    1995-04-01

    A number of overflows from a large lava channel and tube system on the southwest rift zone of Mauna Loa were studied. Initial overflows were very low viscosity gas-rich pāhoehoe evidenced by flow-unit aspect ratios and vesicle sizes and contents. Calculated volumetric flow-rates in the channel range between 80 and 890 m3/s, and those of the overflows between 35 and 110 m3/s. After traveling tens to hundreds of meters the tops of these sheet-like overflows were disrupted into a surface composed of clinker and pāhoehoe fragments. After these 'a'ā overflows came to rest, lava from the interiors was able to break out on to the surface as pāhoehoe. The surface structure of a lava flow records the interaction between the differential shear rate (usually correlated with the volumetric flow-rate) and viscosity-induced resistance to flow. However, the interior of a flow, being better insulated, may react differently or record a later set of emplacement conditions. Clefts of toothpaste lava occurring within fields of clinker on proximal-type 'a'ā flows also record different shear rates during different times of flow emplacement. The interplay between viscosity and shear rate determines the final morphological lava type, and although no specific portion of lava ever makes a transition from 'a'ā back to pāhoehoe, parts of a flow can appear to do so.

  13. Flow Components in a NaK Test Loop Designed to Simulate Conditions in a Nuclear Surface Power Reactor

    NASA Astrophysics Data System (ADS)

    Polzin, Kurt A.; Godfroy, Thomas J.

    2008-01-01

    A test loop using NaK as the working fluid is presently in use to study material compatibility effects on various components that comprise a possible nuclear reactor design for use on the lunar surface. A DC electromagnetic (EM) pump has been designed and implemented as a means of actively controlling the NaK flow rate through the system and an EM flow sensor is employed to monitor the developed flow rate. These components allow for the matching of the flow rate conditions in test loops with those that would be found in a full-scale surface-power reactor. The design and operating characteristics of the EM pump and flow sensor are presented. In the EM pump, current is applied to a set of electrodes to produce a Lorentz body force in the fluid. A measurement of the induced voltage (back-EMF) in the flow sensor provides the means of monitoring flow rate. Both components are compact, employing high magnetic field strength neodymium magnets thermally coupled to a water-cooled housing. A vacuum gap limits the heat transferred from the high temperature NaK tube to the magnets and a magnetically-permeable material completes the magnetic circuit. The pump is designed to produce a pressure rise of 34.5 kPa, and the flow sensor's predicted output is roughly 20 mV at the loop's nominal flow rate of 0.114 m3/hr.

  14. Flow Components in a NaK Test Loop Designed to Simulate Conditions in a Nuclear Surface Power Reactor

    NASA Technical Reports Server (NTRS)

    Polzin, Kurt A.; Godfroy, Thomas J.

    2008-01-01

    A test loop using NaK as the working fluid is presently in use to study material compatibility effects on various components that comprise a possible nuclear reactor design for use on the lunar surface. A DC electromagnetic (EM) pump has been designed and implemented as a means of actively controlling the NaK flow rate through the system and an EM flow sensor is employed to monitor the developed flow rate. These components allow for the matching of the flow rate conditions in test loops with those that would be found in a full-scale surface-power reactor. The design and operating characteristics of the EM pump and flow sensor are presented. In the EM pump, current is applied to a set of electrodes to produce a Lorentz body force in the fluid. A measurement of the induced voltage (back-EMF) in the flow sensor provides the means of monitoring flow rate. Both components are compact, employing high magnetic field strength neodymium magnets thermally coupled to a water-cooled housing. A vacuum gap limits the heat transferred from the high temperature NaK tube to the magnets and a magnetically-permeable material completes the magnetic circuit. The pump is designed to produce a pressure rise of 5 psi, and the flow sensor's predicted output is roughly 20 mV at the loop's nominal flow rate of 0.5 GPM.

  15. Design and Implementation of Automatic Air Flow Rate Control System

    NASA Astrophysics Data System (ADS)

    Akbar, A.; Saputra, C.; Munir, M. M.; Khairurrijal

    2016-08-01

    Venturimeter is an apparatus that can be used to measure the air flow rate. In this experiment we designed a venturimeter which equipped with a valve that is used to control the air flow rate. The difference of pressure between the cross sections was measured with the differential pressure sensor GA 100-015WD which can calculate the difference of pressures from 0 to 3737.33 Pa. A 42M048C Z36 stepper motor was used to control the valve. The precision of this motor rotation is about 0.15 °. A Graphical User Interface (GUI) was developed to monitor and set the value of flow rate then an 8-bit microcontroller was used to process the control system In this experiment- the venturimeter has been examined to get the optimal parameter of controller. The results show that the controller can set the stable output air flow rate.

  16. Effects of argon gas flow rate on laser-welding.

    PubMed

    Takayama, Yasuko; Nomoto, Rie; Nakajima, Hiroyuki; Ohkubo, Chikahiro

    2012-01-01

    The purpose of this study was to evaluate the effects of the rate of argon gas flow on joint strength in the laser-welding of cast metal plates and to measure the porosity. Two cast plates (Ti and Co-Cr alloy) of the same metal were abutted and welded together. The rates of argon gas flow were 0, 5 and 10 L/min for the Co-Cr alloy, and 5 and 10 L/min for the Ti. There was a significant difference in the ratio of porosity according to the rate of argon gas flow in the welded area. Argon shielding had no significant effect on the tensile strength of Co-Cr alloy. The 5 L/min specimens showed greater tensile strength than the 10 L/min specimens for Ti. Laser welding of the Co-Cr alloy was influenced very little by argon shielding. When the rate of argon gas flow was high, joint strength decreased for Ti.

  17. Gas-liquid mass transfer and flow phenomena in the Peirce-Smith converter: a water model study

    NASA Astrophysics Data System (ADS)

    Zhao, Xing; Zhao, Hong-liang; Zhang, Li-feng; Yang, Li-qiang

    2018-01-01

    A water model with a geometric similarity ratio of 1:5 was developed to investigate the gas-liquid mass transfer and flow characteristics in a Peirce-Smith converter. A gas mixture of CO2 and Ar was injected into a NaOH solution bath. The flow field, volumetric mass transfer coefficient per unit volume ( Ak/V; where A is the contact area between phases, V is the volume, and k is the mass transfer coefficient), and gas utilization ratio ( η) were then measured at different gas flow rates and blow angles. The results showed that the flow field could be divided into five regions, i.e., injection, strong loop, weak loop, splashing, and dead zone. Whereas the Ak/V of the bath increased and then decreased with increasing gas flow rate, and η steadily increased. When the converter was rotated clockwise, both Ak/V and η increased. However, the flow condition deteriorated when the gas flow rate and blow angle were drastically increased. Therefore, these parameters must be controlled to optimal conditions. In the proposed model, the optimal gas flow rate and blow angle were 7.5 m3·h-1 and 10°, respectively.

  18. Separation Dynamics of Controlled Internal Flow in an Adverse Pressure Gradient

    NASA Astrophysics Data System (ADS)

    Peterson, C. J.; Vukasinovic, B.; Glezer, A.

    2017-11-01

    The effects of fluidic actuation on the dynamic evolution of aggressive internal flow separation is investigated at speeds up to M = 0.4 within a constant-width diffuser branching off of a primary flow duct. It is shown that a spanwise array of fluidic actuators upstream of the separation actively controls the flow constriction (and losses) within the diffuser and consequently the local pressure gradient at its entrance. The effectiveness of the actuation, as may be measured by the increased flow rate that is diverted through the diffuser, scales with its flow rate coefficient. In the presence of actuation (0.7% mass fraction), the mass flow rate in the primary duct increases by 10% while the fraction of the diverted mass flow rate in the diffuser increases by more than 45%. The flow dynamics near separation in the absence and presence of actuation are characterized using high speed particle image velocimetry and analyzed using proper orthogonal and spectral decompositions. In particular, the spectral contents of the incipient boundary layer separation are compared in the absence and presence of actuation with emphasis on the changes in local dynamics near separation as the characteristic cross stream scale of the boundary layer increases with separation delay.

  19. Myocardial perfusion characteristics during machine perfusion for heart transplantation.

    PubMed

    Peltz, Matthias; Cobert, Michael L; Rosenbaum, David H; West, LaShondra M; Jessen, Michael E

    2008-08-01

    Optimal parameters for machine perfusion preservation of hearts prior to transplantation have not been determined. We sought to define regional myocardial perfusion characteristics of a machine perfusion device over a range of conditions in a large animal model. Dog hearts were connected to a perfusion device (LifeCradle, Organ Transport Systems, Inc, Frisco, TX) and cold perfused at differing flow rates (1) at initial device startup and (2) over the storage interval. Myocardial perfusion was determined by entrapment of colored microspheres. Myocardial oxygen consumption (MVO(2)) was estimated from inflow and outflow oxygen differences. Intra-myocardial lactate was determined by (1)H magnetic resonance spectroscopy. MVO(2) and tissue perfusion increased up to flows of 15 mL/100 g/min, and the ratio of epicardial:endocardial perfusion remained near 1:1. Perfusion at lower flow rates and when low rates were applied during startup resulted in decreased capillary flow and greater non-nutrient flow. Increased tissue perfusion correlated with lower myocardial lactate accumulation but greater edema. Myocardial perfusion is influenced by flow rates during device startup and during the preservation interval. Relative declines in nutrient flow at low flow rates may reflect greater aortic insufficiency. These factors may need to be considered in clinical transplant protocols using machine perfusion.

  20. LAV@HAZARD: a Web-GIS Framework for Real-Time Forecasting of Lava Flow Hazards

    NASA Astrophysics Data System (ADS)

    Del Negro, C.; Bilotta, G.; Cappello, A.; Ganci, G.; Herault, A.

    2014-12-01

    Crucial to lava flow hazard assessment is the development of tools for real-time prediction of flow paths, flow advance rates, and final flow lengths. Accurate prediction of flow paths and advance rates requires not only rapid assessment of eruption conditions (especially effusion rate) but also improved models of lava flow emplacement. Here we present the LAV@HAZARD web-GIS framework, which combines spaceborne remote sensing techniques and numerical simulations for real-time forecasting of lava flow hazards. By using satellite-derived discharge rates to drive a lava flow emplacement model, LAV@HAZARD allows timely definition of parameters and maps essential for hazard assessment, including the propagation time of lava flows and the maximum run-out distance. We take advantage of the flexibility of the HOTSAT thermal monitoring system to process satellite images coming from sensors with different spatial, temporal and spectral resolutions. HOTSAT was designed to ingest infrared satellite data acquired by the MODIS and SEVIRI sensors to output hot spot location, lava thermal flux and discharge rate. We use LAV@HAZARD to merge this output with the MAGFLOW physics-based model to simulate lava flow paths and to update, in a timely manner, flow simulations. Thus, any significant changes in lava discharge rate are included in the predictions. A significant benefit in terms of computational speed was obtained thanks to the parallel implementation of MAGFLOW on graphic processing units (GPUs). All this useful information has been gathered into the LAV@HAZARD platform which, due to the high degree of interactivity, allows generation of easily readable maps and a fast way to explore alternative scenarios. We will describe and demonstrate the operation of this framework using a variety of case studies pertaining to Mt Etna, Sicily. Although this study was conducted on Mt Etna, the approach used is designed to be applicable to other volcanic areas around the world.

Top