Sample records for flow volume bfv

  1. Ultrasonic assessment of hepatic blood flow as a marker of mouse hepatocarcinoma.

    PubMed

    Bonnin, Philippe; Villemain, Aude; Vincent, François; Debbabi, Haythem; Silvestre, Jean Sébastien; Contreres, Jean Olivier; Levy, Bernard I; Tobelem, Gérard; Dupuy, Evelyne

    2007-04-01

    Two-dimensional color-coded pulsed Doppler ultrasonography (US) with a 12-MHz linear transducer was used to follow tumor growth and neoangiogenesis development in 12 transgenic mice developing a whole liver hepatocellular carcinoma (HCC) induced by the expression of SV40-T antigen. In this model, male mice developed HCC at various temporal and histologic stages (hyperplastic, four-eight wk; nodular, 12 wk; diffuse carcinoma, 16-20 wk), whereas female mice remained tumor free. Seven age-matched tumor-free mice were used as controls. Liver volume was calculated from B-mode images of the abdomen. Blood flow waveforms were recorded from the hepatic tumor-feeding artery upstream from the tumor vessels, allowing quantitative blood flow velocity measurements. Measurements were performed every four weeks from four to 20 weeks. As early as the hyperplastic stage (eight weeks), liver volume was increased by 2.7-fold, hepatic artery peak-systolic blood flow velocities (BFV) by 1.5-fold, end-diastolic BFV by 1.6-fold and mean BFV by 2.0-fold compared with control values (p < 0.001). Differences increased until 20 weeks and peak-systolic reached 90 +/- 6, end-diastolic 54 +/- 5 and mean BFV 48 +/- 5 cm s(-1). Successive measurements of BFV were reproducible and intraobserver repeatability coefficient values were <3 cm s(-1). In contrast, mesenteric artery BFV, which did not supply tumor region, did not show any significant difference with respect to control values. Thus, an increase in BFV constitutes a functional evaluation of tumor vascularity. In preclinical studies in small animals, measurements of liver volume and blood flow velocities in hepatic tumor-feeding artery provide a useful, reproducible, noninvasive, easy-to-repeat tool to monitor tumor growth and neoangiogenesis in hepatocellular carcinoma in mice.

  2. Factors that affect the postnatal increase in superior mesenteric artery blood flow velocity in very low birth weight preterm infants.

    PubMed

    Havranek, Thomas; Miladinovic, Branko; Wadhawan, Rajan; Carver, Jane D

    2012-04-15

    To identify factors related to the postnatal increase in superior mesenteric artery blood flow velocity (SMA BFV). SMA BFV was measured in 35 infants (birth weight 1047±246 g) on day of life (DOL) 1, 3, 5, 7 10 and 14. Latent curve modeling (LCM) was used to measure the longitudinal change in BFV for each subject, and the correlation between changes in BFV and baseline values. Non-parametric correlations were calculated between BFV and variables previously reported to be related to SMA BFV. There was significant variability in SMA BFV on DOL 1, a significant increase from DOL 1-14, and significant variability in the postnatal increase. Infants with higher enteral feeding volumes had greater increases, while infants receiving positive pressure ventilation or hyperalimentation had lower increases. Several clinical factors affect the postnatal increase in SMA BFV. The use of LCM is useful in longitudinal studies of very low birth weight (VLBW) infants, who are clinically and demographically heterogeneous.

  3. Variability of mammary blood flow in lactating Holstein-Friesian cows during the first twelve weeks of lactation.

    PubMed

    Götze, A; Honnens, A; Flachowsky, G; Bollwein, H

    2010-01-01

    The goals of the present study were to measure mammary blood flow volume (BFV) during the first 12 wk of lactation in dairy cows by using color Doppler sonography and to determine what affects the mammary blood flow. Forty cows were examined via color Doppler sonography on d 1, 7, 14, 28, 56, and 84 after parturition (d 0). The total BFV (BFV(total)) to the 4 mammary glands was calculated by measuring time-averaged maximum velocities (TAMV) and cross-sectional areas (A) of the left and right pudendoepigastric trunks via transrectal color Doppler sonography. Because there were no significant differences in A, TAMV, and BFV between the right and left pudendoepigastric trunks, the means of A and TAMV, and the BFV(total) of both trunks were used for calculations. The intraindividual and interindividual variability of repeated BFV measures quantified by intraclass correlation coefficients were 96 and 98%, respectively. The BFV(total) ranged from 19.9 to 27.9 L/min, with a mean of 22.3+/-4.9 L/min. Interindividual differences in BFV values were attributable to variations in A and TAMV. The interindividual variability of the BFV(total), which was determined using the coefficients of variation of the BFV(total) on individual days, ranged from 16 to 28%. All the cows had similar changes in the BFV(total) during the study. Changes in BFV(total) were not correlated with changes in the mean of A, but there was a good correlation between changes in BFV(total) and in the mean of TAMV (r=0.94). The BFV(total) was highest on d 1 of lactation, decreased 28% by d 7, and remained at this level until d 28. By d 56, the BFV(total) had increased by 15% compared with d 14 and by 10% compared with d 28. The BFV(total) on d 84 was significantly different from all other days except d 56. There were moderate correlations between daily milk yield and BFV on individual days (0.24

  4. Transrectal Doppler sonography of uterine blood flow during the first two weeks after parturition in Simmenthal heifers

    PubMed Central

    Krüger, Lars; Leidl, Stephanie; Bollwein, Heinrich

    2013-01-01

    Transrectal Doppler sonography was used to evaluate uterine blood flow during the first two weeks after parturition in six primiparous Simmental cows. The uterine blood flow was evaluated on the day of parturition (Day 0), once daily from Days 1 to 8 and then every other day until Day 14. Blood flow was quantified by determining the diameter (D), the time-averaged maximum velocity (TAMV), the pulsatility index (PI) and the blood flow volume (BFV) of the uterine arteries ipsilateral and contralateral to the formerly pregnant uterine horn. During the first four days after calving D, TAMV and BFV declined (ipsilateral: TAMV 70%, BFV 87%, contralateral: D 47%, BFV 84%; p < 0.05), while PI increased (ipsilateral 158%, contralateral 100%; p < 0.05) distinctly. Between Days 4 and 14 only the ipsilateral D (12%) and the BFV of both arteries (ipsilateral 5%, contralateral 8%) decreased (p < 0.05). Blood flow variables were very strongly correlated with each other (r > ±0.75, p < 0.05), with negative correlations with PI and positive correlations with all other investigated factors. Overall, this study revealed characteristic changes in uterine perfusion during the first two weeks after parturition in cows that were pronounced during the first four days postpartum. PMID:23820167

  5. Transrectal Doppler sonography of uterine blood flow during the first two weeks after parturition in Simmenthal heifers.

    PubMed

    Heppelmann, Maike; Krüger, Lars; Leidl, Stephanie; Bollwein, Heinrich

    2013-01-01

    Transrectal Doppler sonography was used to evaluate uterine blood flow during the first two weeks after parturition in six primiparous Simmental cows. The uterine blood flow was evaluated on the day of parturition (Day 0), once daily from Days 1 to 8 and then every other day until Day 14. Blood flow was quantified by determining the diameter (D), the time-averaged maximum velocity (TAMV), the pulsatility index (PI) and the blood flow volume (BFV) of the uterine arteries ipsilateral and contralateral to the formerly pregnant uterine horn. During the first four days after calving D, TAMV and BFV declined (ipsilateral: TAMV 70%, BFV 87%, contralateral: D 47%, BFV 84%; p < 0.05), while PI increased (ipsilateral 158%, contralateral 100%; p < 0.05) distinctly. Between Days 4 and 14 only the ipsilateral D (12%) and the BFV of both arteries (ipsilateral 5%, contralateral 8%) decreased (p < 0.05). Blood flow variables were very strongly correlated with each other (r > ±0.75, p < 0.05), with negative correlations with PI and positive correlations with all other investigated factors. Overall, this study revealed characteristic changes in uterine perfusion during the first two weeks after parturition in cows that were pronounced during the first four days postpartum.

  6. Investigation of mammary blood flow changes by transrectal colour Doppler sonography in an Escherichia coli mastitis model.

    PubMed

    Potapow, André; Sauter-Louis, Carola; Schmauder, Sandra; Friker, Jutta; Nautrup, Cordula Poulsen; Mehne, Daniel; Petzl, Wolfram; Zerbe, Holm

    2010-05-01

    The objectives of this preliminary investigation were to evaluate the feasibility of transrectal colour Doppler sonography (TCDS) for determining blood flow of the pudendoepigastric trunk in cows with experimentally induced Escherichia coli Mastitis. Five primiparous Holstein dairy cows, 4-6 months after calving, were examined in two trials. All monitored udder quarters were initially clinically healthy, somatic cell count (SCC) was <50 000 cells/ml and bacteriologically negative. The blood flow of the left and the right pudendoepigastric trunk was described by the blood flow volume (BFV). In the methodological part of the study, the intra-observer precision of the method was evaluated. The coefficients of variation of the BFV were 7.1% for the left and 9.4% for the right pudendoepigastric trunk. The intraclass correlation coefficients of the BFV were 0.99 (P<0.001) for the left and 0.75 (P=0.004) for the right vessel. BFV did not differ significantly between the left and the right side nor between pre- and post-milking nor between oestrus and dioestrus. In the experimental part of the study, significant differences of increasing BFV between 0 and 12 h p.i. (post infectionem) (P=0.043) and decreasing BFV between 12 and 24 h p.i. (P=0.043) were discovered for the pudendoepigastric trunk of the infected right side. In the left-right (control-infection) comparison a significant increase of the right BFV was observed at 12 h p.i. (P=0.043). The difference of an increasing SCC correlated positively with the difference of an increasing BFV between 0 and 12 h p.i. (Spearman's rho=1.00; P=0.043) for the right infected side. It was shown that TCDS is a reproducible technique for investigating pathological mammary blood flow changes at an early stage of acute mastitis.

  7. 4D flow MRI assessment of extracranial-intracranial bypass: qualitative and quantitative evaluation of the hemodynamics.

    PubMed

    Sekine, Tetsuro; Takagi, Ryo; Amano, Yasuo; Murai, Yasuo; Orita, Erika; Matsumura, Yoshio; Kumita, Shin-Ichiro

    2016-03-01

    Our aim was to assess the feasibility of using time-resolved 3D phase-contrast (4D flow) MRI to characterize extracranial-intracranial (EC-IC) bypass. We enrolled 32 patients who underwent EC-IC bypass (15 men, 17 women; mean age 66.4 years). In all, 16 underwent radial artery graft (RAG) bypass and 16 underwent superficial temporal artery (STA) bypass. 4D flow MRI, time-of-flight (TOF) magnetic resonance angiography (MRA), and computed tomography angiography (CTA) were performed. Bypass patency, flow direction, and blood flow volume (BFV) of each artery were determined by 4D flow MRI. Arterial diameters were measured by TOF-MRA and CTA. We compared RAG and STA bypasses by evaluating the flow direction and BFV of each artery. We evaluated the correlation between arterial diameters (measured by CTA or MRA) and the BFV and the detectability of flow direction (measured by 4D flow MRI) of each artery. 4D flow MRI confirmed the patency of each bypass artery. Flow direction of the M1 segment of the middle cerebral artery and BFV in the bypass artery differed between RAG and STA groups (p < 0.01). BFV in the bypass slightly correlated with the diameters on CTA (p < 0.05, R (2) = 0.287). Of the 29 arteries in the circle of Willis, nine were not depicted on 4D flow MRI. Cutoff values for arterial diameters on CTA and TOF-MRA for detecting the artery on 4D flow MRI were 2.4 and 1.8 mm, respectively. 4D flow MRI provided unique information for characterizing EC-IC bypasses, although this detectability is limited when addressing small arteries with slow flow.

  8. Autoregulation of cerebral blood flow in orthostatic hypotension

    NASA Technical Reports Server (NTRS)

    Novak, V.; Novak, P.; Spies, J. M.; Low, P. A.

    1998-01-01

    BACKGROUND AND PURPOSE: We sought to evaluate cerebral autoregulation in patients with orthostatic hypotension (OH). METHODS: We studied 21 patients (aged 52 to 78 years) with neurogenic OH during 80 degrees head-up tilt. Blood flow velocities (BFV) from the middle cerebral artery were continuously monitored with transcranial Doppler sonography, as were heart rate, blood pressure (BP), cardiac output, stroke volume, CO2, total peripheral resistance, and cerebrovascular resistance. RESULTS: All OH patients had lower BP (P<.0001), BFV_diastolic (P<.05), CVR (P<.007), and TPR (P<.02) during head-up tilt than control subjects. In control subjects, no correlations between BFV and BP were found during head-up tilt, suggesting normal autoregulation. OH patients could be separated into those with normal or expanded autoregulation (OH_NA; n=16) and those with autoregulatory failure (OH_AF; n=5). The OH_NA group showed either no correlation between BFV and BP (n=8) or had a positive BFV/BP correlation (R2>.75) but with a flat slope. An expansion of the "autoregulated" range was seen in some patients. The OH_AF group was characterized by a profound fall in BFV in response to a small reduction in BP (mean deltaBP <40 mm Hg; R2>.75). CONCLUSIONS: The most common patterns of cerebral response to OH are autoregulatory failure with a flat flow-pressure relationship or intact autoregulation with an expanded autoregulated range. The least common pattern is autoregulatory failure with a steep flow-pressure relationship. Patients with patterns 1 and 2 have an enhanced capacity to cope with OH, while those with pattern 3 have reduced capacity.

  9. Uterine blood flow in sheep and goats during the peri-parturient period assessed by transrectal Doppler sonography.

    PubMed

    Elmetwally, Mohammed; Bollwein, Heinrich

    2017-01-01

    The aim of the present study was to evaluate uterine blood flow (UBF) during the postpartum period in small ruminants. The study involved measures of UBF in 5 ewes and 5 goats during the first 4 weeks after parturition. Transrectal quantification of UBF was assessed by determining the diameter (DM), time averaged mean velocity (TAMEAN), blood flow volume (BFV), blood flow acceleration (ACCE) and pulsatility index (PI) in the uterine arteries ipsilateral to the previously gravid uterine horn(s) at Wk 20 of gestation and every 3days from the day of parturition (D 0) until Day 27 postpartum (D 27). The diameters of the uterine arteries decreased (P<0.01) in both species during the postpartum period. The results revealed decreases (P<0.0001) in BFV, ACCE and TAMEAN, while PI increased during the postpartum period in both sheep and goats. Furthermore, there were positive correlations (P<0.05) between blood flow parameters in sheep and goats, respectively (BFV and DM, r=0.62 and 0.58; BFV and ACCE, r=0.32 and 0.26; BFV and TAMEAN, r=0.51 and 0.37). There were negative correlations (P<0.05) between PI and other parameters (PI and BFV, r=-0.39 and -0.36; PI and DM, r=-0.54 and -0.24; PI and ACCE, r=-0.58 and -0.48; and PI and TAMEAN, r=-0.80 and -0.79) in sheep and goats, respectively. Altogether, these results indicate that non-invasive Doppler ultrasound parameters provide important information toward understanding changes in the vasculature and its perfusion of the uterus during the postpartum period in sheep and goats. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Variability of uterine blood flow in lactating cows during the second half of gestation.

    PubMed

    Herzog, Kathrin; Koerte, Juliane; Flachowsky, Gerhard; Bollwein, Heinrich

    2011-06-01

    The main goal of the present study was to measure uterine blood flow volume (BFV) in the second half of gestation in lactating German Holstein cows. Furthermore, it was investigated, if there are individual variations in uterine blood flow and correlations between uterine blood flow and maternal weight and the birth weight of the calf. Forty-four cows were examined via color Doppler sonography in gestation weeks (GW) 21, 25, 29, 33, 37 and 39. The cows were allocated in groups based on the following variables: body weight (light ≤ 575 kg, heavy > 575 kg) and birth weight of the calf (light ≤ 42 kg, heavy > 42 kg). The BFV was measured via transrectal Doppler sonography of both uterine arteries. There was a linear increase in uterine BFV throughout the study period from 3053 ± 1143 ml/min to 16912 ± 5793 ml/min. Variation coefficients for inter-individual variations ranged from 34 to 37%. There was a moderate correlation between uterine BFV and birth weight of the calf in weeks 21 to 37 (0.30 ≤ r < 0.49; P < 0.05) and a good correlation in week 39 (r = 0.60; P < 0.0001). Uterine BFV in week 21 was significantly (P < 0.01) higher in heavy cows (3394 ± 1119 ml/min) than in light cows (2658 ± 1064 ml/min). Compared with light cows, the increase in uterine BFV was 32% higher in heavy cows during the study period. In week 21, there was no difference (P > 0.05) in uterine BFV between cows carrying a heavy calf (3351 ± 1130 ml/min) and those carrying a light calf (2796 ± 1115 ml/min). Thereafter, the increase of BFV was 43% higher in cows with a heavy calf than in those carrying a light calf. Cows with different body weights, but same birth weight of calf showed no differences (P > 0.05) in the increase of BFV, while in cows with the same body weight the rise in BFV was higher (P < 0.05) in those cows producing a heavy calf compared to cows carrying calves with light birth weights. In conclusion, there was a linear increase in uterine BFV in lactating Holstein cows during the second half of pregnancy with marked individual variations. Differences in the rise of BFV were more caused by the fetus than by body weight of cows. Copyright © 2011 Elsevier Inc. All rights reserved.

  11. Splanchnic, Thoracoabdominal, and Cerebral Blood Flow Volumes in Healthy Children and Young Adults in Fasting and Postprandial States: Determining Reference Ranges by Using Phase-Contrast MR Imaging.

    PubMed

    Muthusami, Prakash; Yoo, Shi-Joon; Chaturvedi, Rajiv; Gill, Navjot; Windram, Jonathan; Schantz, Daryl; Prsa, Milan; Caro-Dominguez, Pablo; Seed, Mike; Grosse-Wortmann, Lars; Ling, Simon C; Chavhan, Govind B

    2017-10-01

    Purpose To estimate reference ranges for blood flow volume (BFV) in major splanchnic, thoracoabdominal, and neck vessels by using phase-contrast magnetic resonance (MR) imaging in children and young adults in fasting and postprandial states. Materials and Methods In this institutional research ethics board-approved prospective study, healthy volunteers underwent phase-contrast MR imaging in a fasting state and again after a standardized meal. BFV values were reported as medians and ranges, and postmeal to premeal BFV ratios were calculated. BFVs in volunteers divided into two groups according to age (≤18 years old and >18 years old) were compared by using the Mann-Whitney test adjusted for multiple comparisons. Linear regression for internal validation of BFV and Pearson correlation and Bland-Altman analysis for interobserver agreement were used. Results Reference ranges for BFVs were estimated in 39 volunteers (23 male and 16 female; mean age, 21.2 years ± 8.5; range, 9-40 years) and were indexed according to body surface area, with internal validation (R 2 = 0.84-0.92) and excellent interobserver agreement (R 2 = 0.9928). There was an almost 30% increase in total abdominal BFV (P < .0001) in response to a meal, which was the result of a threefold increase in superior mesenteric artery BFV (P < .0001). BFV after the meal remained unaffected in the celiac artery and cerebral circulation. Significantly higher normalized BFVs in the cerebral circulation were measured in children with both preprandial (P = .039) and postprandial (P = .008) status than those in adults. Conclusion Reference ranges for BFVs and changes in BFVs in response to a meal in major splanchnic, thoracoabdominal, and neck vessels were estimated by using phase-contrast MR imaging in healthy volunteers to allow hemodynamic assessment of children and young adults with various diseases. © RSNA, 2017 Online supplemental material is available for this article.

  12. Brain Perfusion and Arterial Blood Flow Velocity During Prolonged Body Tilting.

    PubMed

    Montero, David; Rauber, Sven

    2016-08-01

    It remains unknown whether brain perfusion is preserved and mirrored by middle cerebral blood flow velocity (MCA BFV) during prolonged changes in body posture. Herein, we examined the impact of sustained (180 min) 30° head-up (HUT) and head-down (HDT) tilt on brain perfusion, as determined by MCA BFV and blood flow in the extracranial arteries. In 10 healthy male subjects, arterial diameters, BFVs, and blood flows were determined in the left internal carotid (ICA) and vertebral (VA) arteries using duplex Doppler ultrasound in supine rest, and 5, 20, 60, 120, and 180 min following 30° HUT and HDT. MCA BFV was recorded throughout with transcranial Doppler ultrasound. ICA as well as VA diameters and blood flows were unaltered during HUT. Likewise, brain blood flow and MCA BFV were preserved with HUT. In the HDT protocol, ICA and VA diameters were gradually increased, although ICA, VA, and brain blood flows were preserved. MCA BFV was progressively reduced during HDT. In addition, MCA BFV was positively associated with ICA BFV (β = 0.9) and negatively associated with ICA diameter (β = -125.5). MCA BFV was positively associated with brain blood flow during HUT (β = 0.2) but not HDT. Brain perfusion is preserved whereas MCA BFV is progressively decreased and associated with extracranial arterial BFV during sustained 30° HDT. Therefore, MCA BFV may not be a surrogate of brain perfusion in conditions including prolonged HDT. Montero D, Rauber S. Brain perfusion and arterial blood flow velocity during prolonged body tilting. Aerosp Med Hum Perform. 2016; 87(8):682-687.

  13. Haemodynamic Changes in the Superior Mesenteric Artery Induced by Acupuncture Stimulation on the Lower Limbs

    PubMed Central

    Watanabe, Masashi; Takayama, Shin; Yamamoto, Yoshiko; Nagase, Satoru; Seki, Takashi; Yaegashi, Nobuo

    2012-01-01

    Acupuncture is commonly performed on acupoints. A comparison of quantitative physiological alterations induced by stimulation on different acupoints has never been performed in the superior mesenteric artery (SMA) in humans. Therefore, we investigated changes in blood flow volume (BFV) in the SMA as an indicator of physiological effects induced by stimulation on 3 points. Thirty healthy participants aged 29 ± 10 years (mean ± SD) were enrolled. All participants underwent stimulations on 3 points located in the lower legs: ST36, LR3, and a non-acupoint. Control pertains to a condition with no-stimulation. Stimulation was performed bilaterally with manual rotation of the needles. BFV was measured by ultrasonography before insertion and 10, 20, 30, and 60 minutes after stimulation. Following acupuncture on ST36, BFV increased significantly 20 and 30 minutes after stimulation, compared to BFV before insertion (P < 0.05). Following stimulation on LR3 and the non-acupoint, no significant differences in BFV could be found. Relative to the no-stimulation group, stimulation on LR3, and the non-acupoint, stimulation on ST36 elicited a significant increase in BFV (P < 0.05). The results suggest that stimulation on the different points causes distinct physiological effects in BFV in the SMA. PMID:22675391

  14. Haemodynamic changes in the superior mesenteric artery induced by acupuncture stimulation on the lower limbs.

    PubMed

    Watanabe, Masashi; Takayama, Shin; Yamamoto, Yoshiko; Nagase, Satoru; Seki, Takashi; Yaegashi, Nobuo

    2012-01-01

    Acupuncture is commonly performed on acupoints. A comparison of quantitative physiological alterations induced by stimulation on different acupoints has never been performed in the superior mesenteric artery (SMA) in humans. Therefore, we investigated changes in blood flow volume (BFV) in the SMA as an indicator of physiological effects induced by stimulation on 3 points. Thirty healthy participants aged 29 ± 10 years (mean ± SD) were enrolled. All participants underwent stimulations on 3 points located in the lower legs: ST36, LR3, and a non-acupoint. Control pertains to a condition with no-stimulation. Stimulation was performed bilaterally with manual rotation of the needles. BFV was measured by ultrasonography before insertion and 10, 20, 30, and 60 minutes after stimulation. Following acupuncture on ST36, BFV increased significantly 20 and 30 minutes after stimulation, compared to BFV before insertion (P < 0.05). Following stimulation on LR3 and the non-acupoint, no significant differences in BFV could be found. Relative to the no-stimulation group, stimulation on LR3, and the non-acupoint, stimulation on ST36 elicited a significant increase in BFV (P < 0.05). The results suggest that stimulation on the different points causes distinct physiological effects in BFV in the SMA.

  15. Hemodynamic changes in the brachial artery induced by acupuncture stimulation on the lower limbs: a single-blind randomized controlled trial.

    PubMed

    Watanabe, Masashi; Takayama, Shin; Hirano, Atsushi; Seki, Takashi; Yaegashi, Nobuo

    2012-01-01

    Acupuncture is commonly performed at acupoints. No comparisons of quantitative physiological alterations in the brachial artery (BA) induced by the stimulation of different acupoints in the lower limbs have been performed in humans. Therefore, we investigated changes in blood flow volume (BFV) in the BA as an indicator of the physiological effects induced by stimulation at 3 points. Seventy-five healthy participants aged 33 ± 9 years (mean ± SD) were enrolled and randomly assigned to 3 groups; they received stimulation at 3 different points located on the lower limbs: ST36, LR3, and a non-acupoint. Stimulation was performed bilaterally with manual rotation of the needles. Using ultrasonography, BFV was measured continuously from rest to 180 seconds after stimulation. LR3 stimulation significantly increased BFV compared to that before needle insertion. Meanwhile, stimulation at ST36 and the non-acupoint significantly decreased BFV compared to that before needle insertion. Stimulation at LR3 elicited a significant increase in BFV compared to that at ST36 and the non-acupoint. The results suggest that the stimulation of different points on the lower limbs causes distinct physiological effects on BFV in the BA.

  16. Prediction of clinical outcome using blood flow volume in the superior mesenteric artery in patients with pseudomyxoma peritonei treated by cytoreductive surgery.

    PubMed

    Dohan, A; Barral, M; Eveno, C; Lo Dico, R; Kaci, R; Pasteur-Rousseau, A; Soyer, P; Pocard, M; Bonnin, P

    2017-10-01

    Pseudomyxoma peritonei (PMP) is a rare carcinomatosis limited to the peritoneal cavity, mainly supplied by the superior mesenteric artery (SMA). The only curative treatment is cytoreductive surgery (CRS) associated with hyperthermic intraperitoneal chemotherapy. This study aimed to evaluate the ability of blood flow volume (BFV) recorded in the SMA using Doppler ultrasonography pre-operatively to predict the extent and resectability of the disease and post-operatively to assess clinical outcome. BFV was measured in the SMA of forty-nine patients before and the year following CRS. Patients were categorized in 3 groups according to clinical and surgical outcomes: group-1 (n = 22): patient with completed CRS, group-2 (n = 16): incomplete resection with slowly progressive disease (alive at 2 years without severe clinical symptoms), group-3 (n = 11): incomplete resection and with severe clinical symptoms or dead within two years. Pre-operative mean SMA BFV was higher in group-2 (510 mL/min, p = 0.027) and in group-3 (572 mL/min, p = 0.004) than in group-1 (378 mL/min). After surgery, BFV dropped to normal values (203 mL/min, p = 0.001) in group-1, and to 423 mL/min (p = 0.047) in group-2. It remained elevated in group-3 (626 mL/min, p = 0.566). BFV allowed stratification of 1) resectability before CRS (group-2 and -3 vs group-1, area under the ROC curve: 0.794 [0.650-0.939]), and 2) non progression after incomplete CRS (group-3 vs group-2, area under the ROC curve: 0.827 [0.565-1.00]. Pre-operative BFV in the SMA correlates with extent and resectability of PMP. After incomplete surgery, post-operative BFV might aid in identifying patients who may benefit of post-operative therapy. Copyright © 2017 Elsevier Ltd, BASO ~ The Association for Cancer Surgery, and the European Society of Surgical Oncology. All rights reserved.

  17. Four-Dimensional Flow MRI Analysis of Cerebral Blood Flow Before and After High-Flow Extracranial-Intracranial Bypass Surgery With Internal Carotid Artery Ligation.

    PubMed

    Orita, Erika; Murai, Yasuo; Sekine, Tetsuro; Takagi, Ryo; Amano, Yasuo; Ando, Takahiro; Iwata, Kotomi; Obara, Makoto; Kumita, Shinichiro

    2018-05-11

    The hemodynamic changes that occur after high-flow (extracranial-intracranial) EC-IC bypass surgery with internal carotid artery (ICA) ligation are not well known. To assess blood flow changes after high-flow EC-IC bypass with ICA ligation by time-resolved 3-dimensional phase-contrast (4D Flow) magnetic resonance imaging (MRI). We enrolled 11 patients who underwent high-flow EC-IC bypass. 4D Flow MRI was performed before and after surgery to quantify the blood flow volume (BFV) of the ipsilateral ICA (BFViICA), bypass artery (BFVbypass), contralateral ICA (BFVcICA), and basilar artery (BFVBA). Subsequently, we calculated the total BFV (BFVtotal = BFViICA + BFVcICA + BFVBA [before surgery], BFVcICA + BFVBA + BFVbypass [after surgery]). The BFV changes after bypass was statistically analyzed. BFVbypass was slightly lower than BFViICA, but the difference was not statistically significant (3.84 ± 0.94 vs 4.42 ± 1.38 mL/s). The BFVcICA and BFVBA significantly increased after bypass surgery (BFVcICA 5.89 ± 1.44 vs 7.22 ± 1.37 mL/s [P = .0018], BFVBA 3.06 ± 0.41 vs 4.12 ± 0.38 mL/s [P < .001]). The BFVtotal significantly increased after surgery (13.37 ± 2.58 vs 15.18 ± 1.77 mL/s [P = .015]). There was no evidence of hyperperfusion syndrome in any cases. After high-flow EC-IC bypass with permanent ICA ligation, the bypass artery could partially compensate for the loss of BFV of the sacrificed ICA. The increased flow of the contralateral ICA and BA supply collateral blood flow. Clinically irrelevant hyperperfusion was observed.

  18. [Electrophysiological markers of middle cerebral artery blood flow velocity in healthy subjects].

    PubMed

    Fokin, V F; Ponomareva, N V; Kuntsevich, G I

    2013-01-01

    to determine electrophysiological markers of middle cerebral artery blood flow velocity (BFV). transcranial Doppler registration of middle cerebral artery BFV and direct current (DC) potentials recording from surface of head were performed in 30 healthy volunteers. Analysis of correlation between the BFV and DC potentials was used. significant correlation between BFV and DC potential characteristics was observed. The highest correlation was found between BFV in middle cerebral artery and the difference of DC potentials between central and temporal areas of head (r = 0,55; p = 0,003). These areas coincide with the location of middle cerebral artery and the correlation observed may be connected with streaming potential generated by the blood flow in middle cerebral artery. If electrode placement did not coincide with blood current, DC potentials and BFV were not correlated. it is assumed that electrical field created BFV in middle cerebral artery may contribute to the generation of DC potentials registered from the head.

  19. Anti-TNFα therapy early improves hemodynamics in local intestinal and extraintestinal circulations in active Crohn's disease.

    PubMed

    Bonnin, Philippe; Coelho, Jessica; Pocard, Marc; Levy, Bernard I; Marteau, Philippe

    2013-07-01

    Active Crohn's disease affects intestine but may alter other locations as eyes vasculature. Previous studies provide evidence of elevated blood flow velocities (BFv) and volume (BFV) in superior mesenteric artery (SMA). We prospectively studied hemodynamics in feeding arteries of bowel and eyes before and 2 weeks after treatment induction with anti-TNFα. Fifteen patients (5 females, 10 males, 35.4 ± 9.0 years, mean ± SD) with active Crohn's disease for 7.5 ± 7.7 years were enrolled. Ultrasound imaging was performed before and 2 weeks after treatment in SMA and retrobulbar arteries: central retinal (CRA), temporal posterior ciliary (TPCA) and ophthalmic (OA) arteries. Serum markers of inflammation (CRP and fibrinogen), arterial blood pressures (ABP) and skin flow-mediated dilation (sFMD) were measured and patients were compared to 10 control age- and sex-matched subjects. Before treatment, CRP and fibrinogen plasma concentrations, SMA BFV (339 ± 100 mL/min) were higher in patients than in controls by 8.5-fold (p<0.001), 1.4-fold (p<0.01) and 1.5-fold, respectively (p<0.01). BFv in CRA (3.5 ± 0.7 cm/s) and TPCA (4.4 ± 1.0 cm/s), sFMD (371 ± 469%) were significantly lower than in controls by 83%, 73% and 52% respectively (p<0.05). Two weeks after treatment, CRP and fibrinogen decreased, SMA BFV was normalized (230 ± 39L/min, p<0.01), BFv in CRA, TPCA and OA increased respectively to 4.0 ± 1.1 (p<0.05), 5.2 ± 1.4 (p<0.001), 8.9 ± 3 cm/s (p<0.05). ABP and sFMD remained unchanged. In active Crohn's disease, a first anti-TNFα administration rapidly normalized concomitantly plasma inflammatory markers and blood-flows in the mesenteric and retrobulbar arteries without affecting blood pressure and endothelial function. Copyright © 2012 European Crohn's and Colitis Organisation. Published by Elsevier B.V. All rights reserved.

  20. Multimodal pressure-flow method to assess dynamics of cerebral autoregulation in stroke and hypertension.

    PubMed

    Novak, Vera; Yang, Albert C C; Lepicovsky, Lukas; Goldberger, Ary L; Lipsitz, Lewis A; Peng, Chung-Kang

    2004-10-25

    This study evaluated the effects of stroke on regulation of cerebral blood flow in response to fluctuations in systemic blood pressure (BP). The autoregulatory dynamics are difficult to assess because of the nonstationarity and nonlinearity of the component signals. We studied 15 normotensive, 20 hypertensive and 15 minor stroke subjects (48.0 +/- 1.3 years). BP and blood flow velocities (BFV) from middle cerebral arteries (MCA) were measured during the Valsalva maneuver (VM) using transcranial Doppler ultrasound. A new technique, multimodal pressure-flow analysis (MMPF), was implemented to analyze these short, nonstationary signals. MMPF analysis decomposes complex BP and BFV signals into multiple empirical modes, representing their instantaneous frequency-amplitude modulation. The empirical mode corresponding to the VM BP profile was used to construct the continuous phase diagram and to identify the minimum and maximum values from the residual BP (BPR) and BFV (BFVR) signals. The BP-BFV phase shift was calculated as the difference between the phase corresponding to the BPR and BFVR minimum (maximum) values. BP-BFV phase shifts were significantly different between groups. In the normotensive group, the BFVR minimum and maximum preceded the BPR minimum and maximum, respectively, leading to large positive values of BP-BFV shifts. In the stroke and hypertensive groups, the resulting BP-BFV phase shift was significantly smaller compared to the normotensive group. A standard autoregulation index did not differentiate the groups. The MMPF method enables evaluation of autoregulatory dynamics based on instantaneous BP-BFV phase analysis. Regulation of BP-BFV dynamics is altered with hypertension and after stroke, rendering blood flow dependent on blood pressure.

  1. Compensatory patterns of collateral flow in stroke patients with unilateral and bilateral carotid stenosis.

    PubMed

    Fang, Hui; Song, Bo; Cheng, Bo; Wong, Ka Sing; Xu, Yu Ming; Ho, Stella Sin Yee; Chen, Xiang Yan

    2016-03-18

    Collateral pathways are important in maintaining adequate cerebral blood flow in patients with carotid stenosis. We aimed to evaluate the hemodynamic patterns in relation to carotid stenosis in acute stroke patients. Consecutive 586 stroke patients in a hospital based cohort were included in the present study. Carotid duplex was performed to identify patients with absolute minimal diameter reductions of 50% or greater in their internal carotid arteries (ICAs). Color velocity imaging quantification ultrasound (CVIQ) was used to measure extracranial arterial blood flow volume (BFV) in bilateral common carotid arteries (CCAs) and bilateral vertebral arteries (VAs). The absolute values of BFV and the ratios were compared between patients with and without ICA stenosis. Among 586 acute ischemic stroke patients (mean age: 67.5 ± 12.4y), ICA stenosis was detected in 112 patients (19.1%), including unilateral ICA stenosis in 81 patients (13.8%) and bilateral ICA stenosis in 31 patients (5.3%). Among patients with unilateral ICA stenosis, the BFV in contralateral CCA was significantly higher than that in ipsilateral CCA (325.5 ± 99.8 mL/min vs. 242.2 ± 112.2 mL/min, P < 0.001). Among patients with bilateral ICA stenosis, the sum of BFV in bilateral VAs accounted for 22% of the whole cerebral blood flow, which was significantly higher than that in those without ICA stenosis (14.8%, P < 0.001) or with unilateral ICA stenosis (16.9%, P = 0.007). In patients with unilateral carotid stenosis, contralateral carotid blood flow increases to compensate decreased blood flow, while posterior circulation may compensate for the decreased brain perfusion in those with bilateral carotid stenosis.

  2. Doppler sonography of the uterine arteries during a superovulatory regime in cattle. Uterine blood flow in superovulated cattle.

    PubMed

    Honnens, A; Niemann, H; Paul, V; Meyer, H H D; Bollwein, H

    2008-09-15

    Transrectal color Doppler sonography was used to investigate the effects of a gonadotropin treatment to induce superovulation on uterine blood flow and its relationship with steroid hormone levels, ovarian response and embryo yield in dairy cows. The estrous cycle of 42 cows was synchronized by using PGF(2alpha) during diestrus and GnRH 48 h later (Day 0). Cows were examined on the day of eCG (2750 IU)-administration (Day 10), 3 days after eCG (Day 13) and 7 days after artificial insemination (Day 22), including the determination of total estrogens (E) and progesterone (P(4)) in peripheral plasma. Eight days after insemination (Day 23) the uterus was flushed and the number of total ova and embryos as well as transferable embryos was determined. The ovarian response was defined by the number of follicles>5.0mm in diameter on Day 13 and the number of corpora lutea on Day 22. Uterine blood flow was reflected by the blood flow volume (BFV) and the pulsatility index (PI) in the uterine arteries. Both variables showed distinct changes throughout the superovulatory cycle: BFV increased by 94% and PI decreased by 30% between Days 10 and 22 (P<0.0001). On Day 13, BFV but not PI correlated with follicle numbers (r=0.35; P<0.05); no correlation was found with E and P(4) (P>0.05). On Day 22, BFV correlated positively and PI correlated negatively with the number of corpora lutea (r=0.45 and r=-0.37; P<0.05) and P(4) (r=0.39 and r=-0.30; P<0.05). The number of transferable embryos was solely related to BFV measured on Day 13 (r=0.32; P<0.05). Our results show for the first time that in cows a superovulatory treatment is associated with a marked increase in BFV and a marked decrease in PI in the uterine arteries, concurrent with the development of multiple follicles and corpora lutea. However, transrectal color Doppler sonography of the uterine arteries does not facilitate the prediction of embryo yields following superovulatory treatment.

  3. Multimodal pressure-flow method to assess dynamics of cerebral autoregulation in stroke and hypertension

    PubMed Central

    Novak, Vera; Yang, Albert CC; Lepicovsky, Lukas; Goldberger, Ary L; Lipsitz, Lewis A; Peng, Chung-Kang

    2004-01-01

    Background This study evaluated the effects of stroke on regulation of cerebral blood flow in response to fluctuations in systemic blood pressure (BP). The autoregulatory dynamics are difficult to assess because of the nonstationarity and nonlinearity of the component signals. Methods We studied 15 normotensive, 20 hypertensive and 15 minor stroke subjects (48.0 ± 1.3 years). BP and blood flow velocities (BFV) from middle cerebral arteries (MCA) were measured during the Valsalva maneuver (VM) using transcranial Doppler ultrasound. Results A new technique, multimodal pressure-flow analysis (MMPF), was implemented to analyze these short, nonstationary signals. MMPF analysis decomposes complex BP and BFV signals into multiple empirical modes, representing their instantaneous frequency-amplitude modulation. The empirical mode corresponding to the VM BP profile was used to construct the continuous phase diagram and to identify the minimum and maximum values from the residual BP (BPR) and BFV (BFVR) signals. The BP-BFV phase shift was calculated as the difference between the phase corresponding to the BPR and BFVR minimum (maximum) values. BP-BFV phase shifts were significantly different between groups. In the normotensive group, the BFVR minimum and maximum preceded the BPR minimum and maximum, respectively, leading to large positive values of BP-BFV shifts. Conclusion In the stroke and hypertensive groups, the resulting BP-BFV phase shift was significantly smaller compared to the normotensive group. A standard autoregulation index did not differentiate the groups. The MMPF method enables evaluation of autoregulatory dynamics based on instantaneous BP-BFV phase analysis. Regulation of BP-BFV dynamics is altered with hypertension and after stroke, rendering blood flow dependent on blood pressure. PMID:15504235

  4. Nonlinear assessment of cerebral autoregulation from spontaneous blood pressure and cerebral blood flow fluctuations.

    PubMed

    Hu, Kun; Peng, C K; Czosnyka, Marek; Zhao, Peng; Novak, Vera

    2008-03-01

    Cerebral autoregulation (CA) is an most important mechanism responsible for the relatively constant blood flow supply to brain when cerebral perfusion pressure varies. Its assessment in nonacute cases has been relied on the quantification of the relationship between noninvasive beat-to-beat blood pressure (BP) and blood flow velocity (BFV). To overcome the nonstationary nature of physiological signals such as BP and BFV, a computational method called multimodal pressure-flow (MMPF) analysis was recently developed to study the nonlinear BP-BFV relationship during the Valsalva maneuver (VM). The present study aimed to determine (i) whether this method can estimate autoregulation from spontaneous BP and BFV fluctuations during baseline rest conditions; (ii) whether there is any difference between the MMPF measures of autoregulation based on intra-arterial BP (ABP) and based on cerebral perfusion pressure (CPP); and (iii) whether the MMPF method provides reproducible and reliable measure for noninvasive assessment of autoregulation. To achieve these aims, we analyzed data from existing databases including: (i) ABP and BFV of 12 healthy control, 10 hypertensive, and 10 stroke subjects during baseline resting conditions and during the Valsalva maneuver, and (ii) ABP, CPP, and BFV of 30 patients with traumatic brain injury (TBI) who were being paralyzed, sedated, and ventilated. We showed that autoregulation in healthy control subjects can be characterized by specific phase shifts between BP and BFV oscillations during the Valsalva maneuver, and the BP-BFV phase shifts were reduced in hypertensive and stroke subjects (P < 0.01), indicating impaired autoregulation. Similar results were found during baseline condition from spontaneous BP and BFV oscillations. The BP-BFV phase shifts obtained during baseline and during VM were highly correlated (R > 0.8, P < 0.0001), showing no statistical difference (paired-t test P > 0.47). In TBI patients there were strong correlations between phases of ABP and CPP oscillations (R = 0.99, P < 0.0001) and, thus, between ABP-BFV and CPP-BFV phase shifts (P < 0.0001, R = 0.76). By repeating the MMPF 4 times on data of TBI subjects, each time on a selected cycle of spontaneous BP and BFV oscillations, we showed that MMPF had better reproducibility than traditional autoregulation index. These results indicate that the MMPF method, based on instantaneous phase relationships between cerebral blood flow velocity and peripheral blood pressure, has better performance than the traditional standard method, and can reliably assess cerebral autoregulation dynamics from ambulatory blood pressure and cerebral blood flow during supine rest conditions.

  5. Nonlinear Assessment of Cerebral Autoregulation from Spontaneous Blood Pressure and Cerebral Blood Flow Fluctuations

    PubMed Central

    Peng, C. K.; Czosnyka, Marek; Zhao, Peng

    2009-01-01

    Cerebral autoregulation (CA) is an most important mechanism responsible for the relatively constant blood flow supply to brain when cerebral perfusion pressure varies. Its assessment in nonacute cases has been relied on the quantification of the relationship between noninvasive beat-to-beat blood pressure (BP) and blood flow velocity (BFV). To overcome the nonstationary nature of physiological signals such as BP and BFV, a computational method called multimodal pressure-flow (MMPF) analysis was recently developed to study the nonlinear BP–BFV relationship during the Valsalva maneuver (VM). The present study aimed to determine (i) whether this method can estimate autoregulation from spontaneous BP and BFV fluctuations during baseline rest conditions; (ii) whether there is any difference between the MMPF measures of autoregulation based on intra-arterial BP (ABP) and based on cerebral perfusion pressure (CPP); and (iii) whether the MMPF method provides reproducible and reliable measure for noninvasive assessment of autoregulation. To achieve these aims, we analyzed data from existing databases including: (i) ABP and BFV of 12 healthy control, 10 hypertensive, and 10 stroke subjects during baseline resting conditions and during the Valsalva maneuver, and (ii) ABP, CPP, and BFV of 30 patients with traumatic brain injury (TBI) who were being paralyzed, sedated, and ventilated. We showed that autoregulation in healthy control subjects can be characterized by specific phase shifts between BP and BFV oscillations during the Valsalva maneuver, and the BP–BFV phase shifts were reduced in hypertensive and stroke subjects (P < 0.01), indicating impaired autoregulation. Similar results were found during baseline condition from spontaneous BP and BFV oscillations. The BP–BFV phase shifts obtained during baseline and during VM were highly correlated (R > 0.8, P < 0.0001), showing no statistical difference (paired-t test P > 0.47). In TBI patients there were strong correlations between phases of ABP and CPP oscillations (R = 0.99, P < 0.0001) and, thus, between ABP–BFV and CPP–BFV phase shifts (P < 0.0001, R = 0.76). By repeating the MMPF 4 times on data of TBI subjects, each time on a selected cycle of spontaneous BP and BFV oscillations, we showed that MMPF had better reproducibility than traditional autoregulation index. These results indicate that the MMPF method, based on instantaneous phase relationships between cerebral blood flow velocity and peripheral blood pressure, has better performance than the traditional standard method, and can reliably assess cerebral autoregulation dynamics from ambulatory blood pressure and cerebral blood flow during supine rest conditions. PMID:18080758

  6. Uterine artery flow velocity waveform, arterial flow indices, follicular dynamics, and sex hormones during preovulatory period in synchronized ovulatory cycle of Bos indicus beef cows.

    PubMed

    Moonmanee, Tossapol; Navanukraw, Chainarong; Yama, Punnawut; Jitjumnong, Jakree

    2018-03-01

    A greater understanding of the uterine artery's (UtA) biology is essential to the increase in female reproductive abilities. The UtA flow velocity waveform, blood flow volume (BFV), pulsatility and resistance indices (PI and RI), blood flow velocities, dynamics of the dominant follicle (DF), and estradiol (E2) and progesterone (P4) levels in an induced ovulatory cycle were evaluated in Thai native cattle. Twenty cows were induced with synchronized ovulation through a P4-releasing device, from Day -9 to Day -4, concurrent with the administration of two doses of a gonadotropin-releasing hormone on Day -9 and Day -1, and two doses of prostaglandin F 2α on Day -4 and 8 h later. Day 0 was designated as the day of ovulation. The cows underwent Doppler sonographic determination and blood collection from Day -4 to Day 0. The cows were classified in the non-ovulating (n = 5) and ovulating groups (n = 15). The ovulating cows presented higher BFV values, blood flow velocities, DF growth rates, and E2 levels; yet lower PI values and P4 concentrations, than those of the non-ovulating cows. The BFV values and the blood flow velocities were greater, but the RI and PI values were lower in the ovulatory side UtA than in the contraovulatory side UtA. The BFV values were positively correlated with blood flow velocities, DF growth rates and E2 concentrations in the ovulating cows; confirming the importance of UtA blood flow, follicular growth, and E2-vasodilation during preovulatory phase in the induced ovulatory cycle of Bos indicus beef cows. Copyright © 2018 Society for Biology of Reproduction & the Institute of Animal Reproduction and Food Research of Polish Academy of Sciences in Olsztyn. Published by Elsevier B.V. All rights reserved.

  7. Correlation between blood flow velocity in the middle cerebral artery and EEG during cognitive effort.

    PubMed

    Szirmai, Imre; Amrein, Ilona; Pálvölgyi, László; Debreczeni, Róbert; Kamondi, Anita

    2005-06-01

    Cognitive effort modifies blood flow velocity (BFV) in the middle cerebral artery (MCA) which can be recorded by transcranial Doppler sonography (TCD). EEG parameters can be used as indicators of cortical activation. To find temporal and spatial relation between circulatory and bioelectric phenomena, we used combined EEG and TCD measurements during cognitive experiments. Bilateral BFV in the MCAs and 16-channel scalp EEG were recorded during mental arithmetic (MA) and verbal fluency (VF) tests in 12 healthy volunteers. Temporal profile of BFV, heart rate (HR), EEG central frequency (CF), relative alpha power (ralphap), and laterality index (Li) for BFV and CF were statistically analysed. During mental effort, BFV changes showed a reproducible pattern, which was different in MA and VF tests. The Li(BFV) correlated with handedness in 9/12 subjects (75%) in the VF, and in 6/12 subjects (50%) in the MA test. Significant correlation was found between Li(BFV) and Li(CF) during VF (r(2) = 0.69). Li was more indicative for the hemispheric dominance in the VF than in the MA test. During VF test, correlation between HR and BFV was significant in 7/12 subjects. CF and ralphap provide real time assessment of the functional state of the brain tissue during cognition. The correlation between CF and BFV during mental activity suggests a short latency neurogenic and a long latency, supposedly chemical regulation of regional blood flow. Parallel analysis of EEG and flow parameters increases the confidence of determining hemispheric dominance and provides an alternative to study physiological consequences of cognitive processes.

  8. Lateralization of cerebral blood flow velocity changes during auditory stimulation: a functional transcranial Doppler study.

    PubMed

    Carod Artal, Francisco Javier; Vázquez Cabrera, Carolina; Horan, Thomas Anthony

    2004-01-01

    Transcranial Doppler ultrasonography (TCD) permits the assessment of cognitively induced cerebral blood flow velocity (BFV) changes. We sought to investigate the lateralization of BFV acceleration induced by auditory stimulation and speech in a normal population. TCD monitoring of BFV in the middle cerebral arteries (MCA) was performed in 30 normal right-handed volunteers (average age = 31.7 years). Noise stimulation, speech, and instrumental music were administered during 60 sec to both ears by means of earphones. Auditory stimulation induced a significant BFV increase in the ipsilateral MCA compared to BFV during the preceding rest periods. Left MCA BFV increased by an average of 7.1% (noise), 8.4% (language), and 5.2% (melody) over baseline values, and right MCA BFV increased 5.1%, 3.1%, and 4.2%, respectively. Speech stimulation produced a significant increase in BFV in the left hemisphere MCA (from 49.86 to 54.03 cm/sec; p < .0001). Left MCA BFV response to speech stimulation may reflect the dominance of the left hemisphere in language processing by right-handed individuals. Due to the high temporal resolution of TCD we were able show a habituation effect during the 60-sec stimulation period.

  9. Relationships between ovarian blood flow and ovarian response to eCG-treatment of dairy cows.

    PubMed

    Honnens, A; Niemann, H; Herzog, K; Paul, V; Meyer, H H D; Bollwein, H

    2009-07-01

    The goal of the present study was to investigate ovarian blood flow and ovarian response in cows undergoing a gonadotropin treatment to induce a superovulatory response, using transrectal colour Doppler sonography. Forty-two cows including 19 cross-bred, 14 German Holstein and 9 German Black Pied cows were examined sonographically before hormonal stimulation on Day 10 of the oestrous cycle, three days after administration of eCG (Day 13) and seven days after artificial insemination (Day 7(p.i.)). After each Doppler examination, blood was collected for determination of total oestrogens (E) and progesterone (P4) in peripheral plasma. The blood flow volume (BFV) and pulsatility index (PI), which is a measure for blood flow resistance, were determined in the ovarian artery, and B-mode sonography was used to count dominant follicles and corpora lutea. Important criteria to assess the ovarian response following the hormonal treatment were the number of follicles >5mm in diameter on Day 13 and the number of corpora lutea on Day 7(p.i.) per cow. The number of follicles ranged from 2 to 61 (mean+/-S.E.M.: 17.5+/-1.7) and corpora lutea from 0 to 50 (mean+/-S.E.M.: 17.0+/-1.6). The BFV increased from 28.4 to 45.0 ml/min between Days 10 and 13 and reached a maximum of 108.5 ml/min on Day 7(p.i.) The PI decreased from 6.25 on Day 10 to 4.70 on Day 13 and to 2.10 on Day 7(p.i.) The BFV and PI on Day 13 did not correlate with the number of follicles (P>0.05). However, on Day 7(p.i.) the number of corpora lutea correlated positively with the BFV (r=0.64; P<0.0001), and an inverse relationship was found for the PI (r=-0.51; P=0.0005). There were no correlations (P>0.05) between the BFV and PI on Day 10 and the number of follicles on Day 13 or the number of corpora lutea on Day 7(p.i.) Results of the present study show that in cows, a hormonal treatment to induce a superovulatory response yielded a marked increase in BFV and a marked decrease in PI in the ovarian artery. However, there was no correlation between BFV and PI in the ovarian arteries before hormonal stimulation and the number of follicles and corpora lutea that developed after stimulation. Thus BFV and PI measured in the ovarian arteries have limited diagnostic value to predict the outcome of a gonadotropin treatment.

  10. Transdural doppler ultrasonography monitors cerebral blood flow changes in relation to motor tasks.

    PubMed

    Hatanaka, Nobuhiko; Tokuno, Hironobu; Nambu, Atsushi; Takada, Masahiko

    2009-04-01

    Monitoring changes in cerebral blood flow in association with neuronal activity has widely been used to evaluate various brain functions. However, current techniques do not directly measure blood flow changes in specified blood vessels. The present study identified arterioles within the cerebral cortex by echoencephalography and color Doppler imaging, and then measured blood flow velocity (BFV) changes in pulsed-wave Doppler mode. We applied this "transdural Doppler ultrasonography (TDD)" to examine BFV changes in the cortical motor-related areas of monkeys during the performance of unimanual (right or left) and bimanual key-press tasks. BFV in the primary motor cortex (MI) was increased in response to contralateral movement. In each of the unimanual and bimanual tasks, bimodal BFV increases related to both the instruction signal and the movement were observed in the supplementary motor area (SMA). Such BFV changes in the SMA were prominent during the early stage of task training and gradually decreased with improvements in task performance, leaving those in the MI unchanged. Moreover, BFV changes in the SMA depended on task difficulty. The present results indicate that TDD is useful for evaluating regional brain functions.

  11. Validation of color Doppler ultrasonography for evaluating the uterine blood flow and perfusion during late normal pregnancy and uterine torsion in buffaloes.

    PubMed

    Hussein, Hassan A

    2013-04-15

    The aim of this study was to verify the efficacy of color Doppler ultrasonography for diagnosis of degree and duration of uterine torsion in buffaloes. In Assiut province/Upper Egypt, 65 buffaloes (37 with uterine torsion, 28 with normal late pregnancy) were examined clinically and using Doppler ultrasonography. The Doppler indices including resistance index (RI), pulsatility index (PI), time-averaged maximum velocity (TAMV), and blood flow volume (BFV) in the arteries ipsilateral to the uterine torsion (IPUT) and in arteries contralateral to the uterine torsion (COUT) were recorded. Methods of correction were documented along with dam and calf survival. Torsion was recorded postcervically with vaginal involvement in 35/37 (94.6%) of the cases. The degrees of uterine torsion were light and high in 9/37 (24.3%) and 28/37 (75.7%) of the cases, respectively (P = 0.001). Right uterine torsion was present in 36/37 (97.3%) of the cases (P = 0.0001). Pulsatility index, RI, TAMV, and BFV in IPUT and COUT did not differ significantly (P > 0.05) in normal late pregnancy. The PI and RI in IPUT were significantly higher (P < 0.01) than in COUT, and the TAMV and BFV in IPUT were less (P < 0.001) than that in COUT in uterine torsion. The PI and RI of torsion cases in IPUT were higher (P < 0.001) than that in normal pregnancy. Time-averaged maximum velocity and BFV in torsion cases were lower (P < 0.01) than that of normal pregnancy in IPUT. There was approximately 50% of RI and PI higher than in light degree uterine torsion in IPUT (P < 0.001). Consequently, TAMV and BFV were greatly lower (P < 0.0001) than that in light degree in IPUT. Pulsatility index and RI were positively correlated (r = 0.856; P < 0.001) with the duration and degree of the uterine torsion, and TAMV and BFV were negatively correlated (r = -0.763; P < 0.001). In all cases of uterine torsion the uterine flow velocity waveform showed high systolic flow and absence of early diastolic flow and poor uterine and placentomal blood perfusion. In conclusion, depicting blood flow within the middle uterine artery using color Doppler sonography could be helpful in correct diagnosis of duration and degree of uterine torsion and concurrently predicting the viability of the fetus and dam. Copyright © 2013 Elsevier Inc. All rights reserved.

  12. Effect of exogenous estradiol Benzoate on uterine blood flow in postpartum dairy cows.

    PubMed

    Rawy, Mohamed; Mido, Shogo; El-Sheikh Ali, Hossam; Derar, Derar; Megahed, Gaber; Kitahara, Go; Osawa, Takeshi

    2018-05-01

    The objective of this study was to assess the uterine blood flow following estradiol benzoate administration in Holstein-Friesian dairy cows by trans-rectal color Doppler ultrasonography. Six healthy lactating Holstein-Friesian cows were examined daily for 10 days starting at 4 weeks postpartum. All the cows, which were clinically healthy based on vaginal mucus scoring and endometrial cytology, were examined by trans-rectal Doppler ultrasonography to measure pulsatility index (PI), resistance index (RI), time average maximum velocity (TAMAX), blood flow volume (BFV) and diameter in the uterine arteries ipsilateral and contralateral to the previously pregnant uterine horn. On the third day of the experiment, the six cows were administered 10 mg intramuscular injection of estradiol-17β (E 2 ).Blood samples were collected at the time of daily examination for the assessment ofE 2 concentrations.The PI and RI values decreased while TAMAX, BFV and diameter of uterine arteries increased in response toE 2 administration (P < 0.05).There was a high correlation between both the ipsilateral and contralateral uterine arteries for all variables that were studied(r = 0.860, P < 0.0001, r = 0.922, P < 0.0001, r = 0.651, P < 0.0001, r = 0.879, P < 0.0001, r = 0.861, P < 0.0001 for the PI, RI, TAMAX, BFV and uterine arteries diameter, respectively).In conclusion, the greater blood concentrations ofE 2 may be responsible for the greater TAMAX, BFV, increased diameters and decreased PI and RI of the uterine arteries during the puerperium in dairy cows. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. [Effect of mental arithmetic and verbal fluency on blood flow velocity in the middle cerebral arteries].

    PubMed

    Amrein, Ilona; Pálvölgyi, László; Debreczeni, Róbert; Kamondi, Anita; Szirmai, Imre

    2004-01-20

    Using transcranial Doppler sonography (TCD), changes in blood flow velocity (BFV) can be measured in the Medial Cerebral Artery (MCA) during cognitive effort. Our goal was to define the time-course and laterality of BFV in healthy volunteers during arithmetic and verbal fluency tasks according to handedness. Twelve subjects (8 right-handed, 4 left-handed) were assessed. The TCD registered BFV in both MCA simultaneously. Heart rate was also recorded using TCD. Finally we included a 16-channel EEG. BFV laterality index (LI) was calculated. Participants were asked to count silently and generate words beginning with a specified letter. To estimate hemispheric differences in BFV, two-tailed Wilcoxon tests were utilized along with correlational analyses. During cognitive effort the BFV changed in a tri-phasic manner in all participants. A 6-8% elevation of BFV was observed in MCAs without latency at the time of the evoking signal. Laterality of BFV developed after 5-13 seconds during cognitive effort in right-, and several seconds later in left-handed subjects. During tasks the BFV increased in the dominant hemisphere up to 2.6-4.7% compared to the subdominant one. We also calculated the LI. During the verbal task the LI agreed with the handedness in 9 out of 12 subjects. During the mental arithmetic task, agreement was found in 6 out of 12 subjects. According to LI results we found a discrepancy between verbal and arithmetic tests in 3 out of 12 subjects. Cognitive effort elicites significant bilateral BFV increases in the MCAs, which suggests fast neurogenic regulation. The course of BFV during mental arithmetic proved to be different from course BFV assessed during the word fluency task. Based on the laterality of the BFV, the word-generation task was more sensitive in determining the dominant hemisphere when compared to the mental arithmetic task. The use of LI may help to estimate hemispheric functions even in pathologic circumstances.

  14. Multimodal Pressure-Flow Analysis: Application of Hilbert Huang Transform in Cerebral Blood Flow Regulation

    NASA Astrophysics Data System (ADS)

    Lo, Men-Tzung; Hu, Kun; Liu, Yanhui; Peng, C.-K.; Novak, Vera

    2008-12-01

    Quantification of nonlinear interactions between two nonstationary signals presents a computational challenge in different research fields, especially for assessments of physiological systems. Traditional approaches that are based on theories of stationary signals cannot resolve nonstationarity-related issues and, thus, cannot reliably assess nonlinear interactions in physiological systems. In this review we discuss a new technique called multimodal pressure flow (MMPF) method that utilizes Hilbert-Huang transformation to quantify interaction between nonstationary cerebral blood flow velocity (BFV) and blood pressure (BP) for the assessment of dynamic cerebral autoregulation (CA). CA is an important mechanism responsible for controlling cerebral blood flow in responses to fluctuations in systemic BP within a few heart-beats. The MMPF analysis decomposes BP and BFV signals into multiple empirical modes adaptively so that the fluctuations caused by a specific physiologic process can be represented in a corresponding empirical mode. Using this technique, we showed that dynamic CA can be characterized by specific phase delays between the decomposed BP and BFV oscillations, and that the phase shifts are significantly reduced in hypertensive, diabetics and stroke subjects with impaired CA. Additionally, the new technique can reliably assess CA using both induced BP/BFV oscillations during clinical tests and spontaneous BP/BFV fluctuations during resting conditions.

  15. Heart rate variability and hemodynamic change in the superior mesenteric artery by acupuncture stimulation of lower limb points: a randomized crossover trial.

    PubMed

    Kaneko, Soichiro; Watanabe, Masashi; Takayama, Shin; Numata, Takehiro; Seki, Takashi; Tanaka, Junichi; Kanemura, Seiki; Kagaya, Yutaka; Ishii, Tadashi; Kimura, Yoshitaka; Yaegashi, Nobuo

    2013-01-01

    Objective. We investigated the relationship between superior mesenteric artery blood flow volume (SMA BFV) and autonomic nerve activity in acupuncture stimulation of lower limb points through heart rate variability (HRV) evaluations. Methods. Twenty-six healthy volunteers underwent crossover applications of bilateral manual acupuncture stimulation at ST36 or LR3 or no stimulation. Heart rate, blood pressure, cardiac index, systemic vascular resistance index, SMA BFV, and HRV at rest and 30 min after the intervention were analyzed. Results. SMA BFV showed a significant increase after ST36 stimulation (0% to 14.1% ± 23.4%, P = 0.007); very low frequency (VLF), high frequency (HF), low frequency (LF), and LF/HF were significantly greater than those at rest (0% to 479.4% ± 1185.6%, P = 0.045; 0% to 78.9% ± 197.6%, P = 0.048; 0% to 123.9% ± 217.1%, P = 0.006; 0% to 71.5% ± 171.1%, P = 0.039). Changes in HF and LF also differed significantly from those resulting from LR3 stimulation (HF: 78.9% ± 197.6% versus -18.2% ± 35.8%, P = 0.015; LF: 123.9% ± 217.1% versus 10.6% ± 70.6%, P = 0.013). Conclusion. Increased vagus nerve activity after ST36 stimulation resulted in increased SMA BFV. This partly explains the mechanism of acupuncture-induced BFV changes.

  16. Autonomic dysfunction affects cerebral neurovascular coupling.

    PubMed

    Azevedo, Elsa; Castro, Pedro; Santos, Rosa; Freitas, João; Coelho, Teresa; Rosengarten, Bernhard; Panerai, Ronney

    2011-12-01

    Autonomic failure (AF) affects the peripheral vascular system, but little is known about its influence on cerebrovascular regulation. Patients with familial amyloidotic polyneuropathy (FAP) were studied as a model for AF. Ten mild (FAPm), 10 severe (FAPs) autonomic dysfunction FAP patients, and 15 healthy controls were monitored in supine and sitting positions for arterial blood pressure (ABP) and heart rate (HR) with arterial volume clamping, and for blood flow velocity (BFV) in posterior (PCA) and contralateral middle cerebral arteries (MCA) with transcranial Doppler. Analysis included resting BFV, cerebrovascular resistance parameters (cerebrovascular resistance index, CVRi; resistance area product, RAP; and critical closing pressure, CrCP), and neurovascular coupling through visually evoked BFV responses in PCA (gain, rate time, attenuation, and natural frequency). In non-stimulation conditions, in each position, there were no significant differences between the groups, regarding HR, BP, resting BFV, and vascular resistance parameters. Sitting ABP was higher than in supine in the three groups, although only significantly in controls. Mean BFV was lower in sitting in all the groups, lacking statistical significance only in FAPs PCA. CVRi and CrCP increased with sitting in all the groups, while RAP increased in controls but decreased in FAPm and FAPs. In visual stimulation conditions, FAPs comparing to controls had a significant decrease of natural frequency, in supine and sitting, and of rate time and gain in sitting position. These results demonstrate that cerebrovascular regulation is affected in FAP subjects with AF, and that it worsens with orthostasis.

  17. Heart Rate Variability and Hemodynamic Change in the Superior Mesenteric Artery by Acupuncture Stimulation of Lower Limb Points: A Randomized Crossover Trial

    PubMed Central

    Watanabe, Masashi; Tanaka, Junichi; Kanemura, Seiki; Kagaya, Yutaka; Ishii, Tadashi; Kimura, Yoshitaka; Yaegashi, Nobuo

    2013-01-01

    Objective. We investigated the relationship between superior mesenteric artery blood flow volume (SMA BFV) and autonomic nerve activity in acupuncture stimulation of lower limb points through heart rate variability (HRV) evaluations. Methods. Twenty-six healthy volunteers underwent crossover applications of bilateral manual acupuncture stimulation at ST36 or LR3 or no stimulation. Heart rate, blood pressure, cardiac index, systemic vascular resistance index, SMA BFV, and HRV at rest and 30 min after the intervention were analyzed. Results. SMA BFV showed a significant increase after ST36 stimulation (0% to 14.1% ± 23.4%, P = 0.007); very low frequency (VLF), high frequency (HF), low frequency (LF), and LF/HF were significantly greater than those at rest (0% to 479.4% ± 1185.6%, P = 0.045; 0% to 78.9% ± 197.6%, P = 0.048; 0% to 123.9% ± 217.1%, P = 0.006; 0% to 71.5% ± 171.1%, P = 0.039). Changes in HF and LF also differed significantly from those resulting from LR3 stimulation (HF: 78.9% ± 197.6% versus −18.2% ± 35.8%, P = 0.015; LF: 123.9% ± 217.1% versus 10.6% ± 70.6%, P = 0.013). Conclusion. Increased vagus nerve activity after ST36 stimulation resulted in increased SMA BFV. This partly explains the mechanism of acupuncture-induced BFV changes. PMID:24381632

  18. Influence of blood flow velocity on arterial distensibility of carotid artery in healthy men.

    PubMed

    Tomoto, Tsubasa; Maeda, Seiji; Sugawara, Jun

    2017-01-01

    Decreased distensibility of carotid artery is independently associated with the incidence of cardiovascular and cerebrovascular events. Arterial distensibility is determined by vascular tone. Since shear stress is an important driving force of vasodilatory substances production form endothelial cells, we hypothesized that local basal (i.e., resting) arterial blood flow velocity is associated with regional arterial distensibility. To test this hypothesis, we determined the influence of local blood flow velocity on carotid arterial distensibility in cross-sectional study design. In a total of 73 apparent healthy men (18-64 years), carotid arterial properties, including measures of carotid arterial distensibility and BFV at rest, were evaluated via B-mode and Doppler ultrasound imaging and applanation tonometry system. Carotid arterial peak BFV and the absolute and normalized pulsatile BFV significantly correlated with age (r = -0.453 to -0.600, p < 0.0001), whereas mean and minimum BFV were not influenced by age. Distensibility coefficient of carotid artery correlated with peak BFV (r = 0.305, p < 0.01) and more strongly with pulsatile (i.e., systolic minus end-diastolic) BFV (r = 0.406, p < 0.0001) and the normalized pulsatile BFV by time-averaged velocity (r = 0.591, p < 0.0001). Multi-regression analysis revealed that age (β = -0.57, p < 0.0001) was the primary independent determinant for distensibility coefficient. In addition with this, carotid lumen diameter (β = -0.202, p < 0.01) and the normalized pulsatile BFV (β = 0.237, p < 0.05) were significant independent determinants of distensibility coefficient. Qualitatively similar results (although inverse in direction) were obtained by use of β-stiffness index. These results suggest that greater gradient of blood flow velocity during a cardiac cycle are favorably associated with distensibility of carotid artery.

  19. Evaluation of cerebral blood flow changes in focal cerebral ischemia rats by using transcranial Doppler ultrasonography.

    PubMed

    Li, Le; Ke, Zheng; Tong, Kai Yu; Ying, Michael

    2010-04-01

    Ischemic stroke is typically characterized by the disruption of cerebral blood flow. This study aimed to consecutively evaluate the cerebral blood flow changes in a focal ischemia rat model during the occlusion-reperfusion procedure and along the recovery stage after stroke. In 12 Sprague Dawley (SD) rats, a middle cerebral artery occlusion/reperfusion (MCAo/r) surgery was conducted, which combines a permanent occlusion of the right common carotid artery (CCA), external carotid artery (ECA) and a transient occlusion of the right internal carotid artery (ICA) and middle cerebral artery (MCA) with a monofilament introduced from the proximal ICA towards the distal right ICA then removed after 90 min. Blood flow velocity (BFV) from the concerned arteries were measured using ultrasonography (13-4 MHz) at the basal stage before the surgery, after the reperfusion stage and during the post-stroke status. At reperfusion stage and after, BFV increased significantly in the left ICA and in the basilar artery (BA) (starting from post-24 h, p < 0.05 vs. basal). Moreover, BFV were reversed in the distal right ICA and reflow was recorded in the right MCA. Time-average maximum BFV in the right MCA at reperfusion and post-stroke 24-96 h was decreased significantly (p < 0.05 vs. basal). The reversed flow in the right ICA was enabled by the settlement of the collateral supply through the circle of Willis which consisted in higher BFV in the opposite ICA and in the BA still 24 h, although the proximal right ICA remain occluded. Ultrasound measurement of BFV helps to provide information on the redistribution of the blood flow supply after the onset of stroke. Copyright 2010 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  20. Cerebral hyperperfusion following carotid endarterectomy: diagnostic utility of intraoperative transcranial Doppler ultrasonography compared with single-photon emission computed tomography study.

    PubMed

    Ogasawara, Kuniaki; Inoue, Takashi; Kobayashi, Masakazu; Endo, Hidehoko; Yoshida, Kenji; Fukuda, Takeshi; Terasaki, Kazunori; Ogawa, Akira

    2005-02-01

    Cerebral hyperperfusion syndrome is a rare but serious complication of carotid endarterectomy (CEA). The aim of the present study was to determine whether intraoperative blood flow velocity (BFV) monitoring in the middle cerebral artery (MCA) by using transcranial Doppler ultrasonography (TCD) could be used as a reliable technique to detect cerebral hyperperfusion following CEA by comparing findings with those of brain single photon emission CT (SPECT). Intraoperative BFV monitoring was attempted in 67 patients undergoing CEA for treatment of ipsilateral internal carotid artery (ICA) stenosis (> or =70%). Cerebral blood flow (CBF) was also assessed using SPECT, which was performed before and immediately after CEA. Intraoperative BFV monitoring was achieved in 60 patients. Of the 60 patients, post-CEA hyperperfusion (CBF increase > or =100%, compared with preoperative values) was observed in six patients. The sensitivity, specificity, and positive predictive value of the BFV increases immediately after declamping of the ICA for detecting post-CEA hyperperfusion was 100%, 94% and 67%, respectively, with a cut-off point 2.0-fold that of preclamping BFV. The sensitivity and specificity of the BFV increases at the end of the procedure for detecting post-CEA hyperperfusion were 100% for both parameters, with cut-off points of 2.0- to 2.2-fold BFV of preclamping value. Hyperperfusion syndrome developed in two patients with post-CEA hyperperfusion, but intracerebral hemorrhage did not occur. In one of these two patients, BFV monitoring was not possible because of failure to obtain an adequate bone window. Intraoperative MCA BFV monitoring by using TCD is a less reliable method to detect cerebral hyperperfusion following CEA than postoperative MCA BFV monitoring, provided adequate monitoring can be achieved.

  1. Cerebrovascular regulation in the postural orthostatic tachycardia syndrome (POTS)

    NASA Technical Reports Server (NTRS)

    Low, P. A.; Novak, V.; Spies, J. M.; Novak, P.; Petty, G. W.

    1999-01-01

    Patients with the postural orthostatic tachycardia syndrome (POTS) have symptoms of orthostatic intolerance despite having a normal orthostatic blood pressure (BP), which suggests some impairment of cerebrovascular regulation. Cerebrovascular autoregulation refers to the maintenance of normal cerebral blood flow in spite of changing BP. Mechanisms of autoregulation include myogenic, metabolic and neurogenic vasoregulation. Beat-to-beat recording of blood-flow velocity (BFV) is possible using transcranial Doppler imaging. It is possible to evaluate autoregulation by regressing deltaBFV to deltaBP during head-up tilt. A number of dynamic methods, relating deltaBFV to deltaBP during sudden induced changes in BP by occluding then releasing peripheral arterial flow or by the Valsalva maneuver. The deltaBFV to deltaBP provides an index of autoregulation. In orthostatic hypotension, the autoregulated range is typically expanded. In contrast, paradoxical vasoconstriction occurs in POTS because of an increased depth of respiration, resulting in hypocapnic cerebrovascular constriction, and impaired autoregulation.

  2. Feasibility of 4D flow MR imaging of the brain with either Cartesian y-z radial sampling or k-t SENSE: comparison with 4D Flow MR imaging using SENSE.

    PubMed

    Sekine, Tetsuro; Amano, Yasuo; Takagi, Ryo; Matsumura, Yoshio; Murai, Yasuo; Kumita, Shinichiro

    2014-01-01

    A drawback of time-resolved 3-dimensional phase contrast magnetic resonance (4D Flow MR) imaging is its lengthy scan time for clinical application in the brain. We assessed the feasibility for flow measurement and visualization of 4D Flow MR imaging using Cartesian y-z radial sampling and that using k-t sensitivity encoding (k-t SENSE) by comparison with the standard scan using SENSE. Sixteen volunteers underwent 3 types of 4D Flow MR imaging of the brain using a 3.0-tesla scanner. As the standard scan, 4D Flow MR imaging with SENSE was performed first and then followed by 2 types of acceleration scan-with Cartesian y-z radial sampling and with k-t SENSE. We measured peak systolic velocity (PSV) and blood flow volume (BFV) in 9 arteries, and the percentage of particles arriving from the emitter plane at the target plane in 3 arteries, visually graded image quality in 9 arteries, and compared these quantitative and visual data between the standard scan and each acceleration scan. 4D Flow MR imaging examinations were completed in all but one volunteer, who did not undergo the last examination because of headache. Each acceleration scan reduced scan time by 50% compared with the standard scan. The k-t SENSE imaging underestimated PSV and BFV (P < 0.05). There were significant correlations for PSV and BFV between the standard scan and each acceleration scan (P < 0.01). The percentage of particles reaching the target plane did not differ between the standard scan and each acceleration scan. For visual assessment, y-z radial sampling deteriorated the image quality of the 3 arteries. Cartesian y-z radial sampling is feasible for measuring flow, and k-t SENSE offers sufficient flow visualization; both allow acquisition of 4D Flow MR imaging with shorter scan time.

  3. Ultrasonic assessment of cerebral blood flow changes during ischemia-reperfusion in 7-day-old rats.

    PubMed

    Bonnin, Philippe; Debbabi, Haythem; Mariani, Jean; Charriaut-Marlangue, Christiane; Renolleau, Sylvain

    2008-06-01

    A model of ischemic brain injury in 7-day-old rat pups has been developed to study perinatal ischemia. It combines permanent occlusion of the distal left middle cerebral artery (LMCA) and transient occlusion of homolateral common carotid artery (LCCA). At removal of the clip on LCCA, reflow allowed brain reperfusion through cortical anastomoses. In 10 rat pups, we measured blood flow velocities (BFV) in main cerebral arteries with 12-MHz ultrasound imaging. At basal states, peak systolic BFV in proximal LMCA was 16.0 +/- 3.0 cm.s(-1). Occlusion of LMCA did not yield significant modifications. Occlusion of LCCA involved only a decrease in BFV to 9.5 +/- 2.6 cm.s(-1) (p < 0.001). Indeed, LMCA was then supply by the right internal carotid and the vertebral arteries through the circle of Willis. In three rat pups, release of occlusion of LCCA was followed by restoration of BFV in the left internal carotid artery and in LMCA, in seven pups, by a reversed flow in the LICA and lower BFV in LMCA (11.9 +/- 2.3, p < 0.05). BFV returned to basal values from h5 to h48 in all animals. In addition, ultrasound imaging is a useful, reproducible, non invasive, easy-to-repeat, method to assess and monitor arterial cerebral blood flow supply in small animals. It helps to characterize changes occurring during cerebral ischemia and reperfusion, particularly the depth of the hypoperfusion, as well as the variability of reflow. In preclinical studies, this method could help to identify what can be assigned to a neuroprotective treatment and what depends on changes in cerebral blood flow supply.

  4. Nonlinear Pressure-Flow Relationship Is Able to Detect Asymmetry of Brain Blood Circulation Associated with Midline Shift

    PubMed Central

    Lo, Men-Tzung; Peng, C.K.; Novak, Vera; Schmidt, Eric A.; Kumar, Ajay; Czosnyka, Marek

    2009-01-01

    Abstract Reliable and noninvasive assessment of cerebral blood flow regulation is a major challenge in acute care monitoring. This study assessed dynamics of flow regulation and its relationship to asymmetry of initial computed tomography (CT) scan using multimodal pressure flow (MMPF) analysis. Data of 27 patients (38 ± 15 years old) with traumatic brain injury (TBI) were analyzed. Patients were selected from bigger cohort according to criteria of having midline shift on initial CT scan and intact skull (no craniotomy or bone flap). The MMPF analysis was used to extract the oscillations in cerebral perfusion pressure (CPP) and blood flow velocity (BFV) signals at frequency of artificial ventilation, and to calculate the instantaneous phase difference between CPP and BFV oscillations. Mean CPP-BFV phase difference was used to quantify pressure and flow relationship. The TBI subjects had smaller mean BP-BFV phase shifts (left, 8.7 ± 9.6; right 10.2 ± 8.3 MCAs, mean ± SD) than values previously obtained in healthy subjects (left, 37.3 ± 7.6 degrees; right, 38.0 ± 8.9 degrees; p < 0.0001), suggesting impaired blood flow regulation after TBI. The difference in phase shift between CPP and BFV in the left and right side was strongly correlated to the midline shift (R = 0.78; p < 0.0001). These findings indicate that the MMPF method allows reliable assessment of alterations in pressure and flow relationship after TBI. Moreover, mean pressure-flow phase shift is sensitive to the displacement of midline of the brain, and may potentially serve as a marker of asymmetry of cerebral autoregulation. PMID:19196074

  5. The Influence of the Orbera Intragastric Balloon Filling Volumes on Weight Loss, Tolerability, and Adverse Events: a Systematic Review and Meta-Analysis.

    PubMed

    Kumar, Nitin; Bazerbachi, Fateh; Rustagi, Tarun; McCarty, Thomas R; Thompson, Christopher C; Galvao Neto, Manoel P; Zundel, Natan; Wilson, Erik B; Gostout, Christopher J; Abu Dayyeh, Barham K

    2017-09-01

    The Orbera intragastric balloon (IGB) has been approved by the US Food and Drug Administration for use in patients with a body mass index (BMI) between 30 and 40 kg/m 2 and is in wide use worldwide as a primary and bridge obesity management tool. The balloon filling volume (BFV) ranges between 400 and 700 mL of saline. Our objective was to determine whether there is an association between BFV and clinically relevant endpoints, namely weight loss outcomes, balloon tolerability, and adverse events. A systematic review of studies investigating the use of the Orbera IGB system for obesity treatment was performed. Data was examined using random effects modelling and meta-regression analyses. Forty-four studies (n = 5549 patients) reported BFV and % total body weight loss (TBWL) at 6 months. Pooled %TBWL at 6 months was 13.2% [95% CI 12.3-14.0]. A funnel plot demonstrated a low risk of publication bias. Meta-regression showed no statistically significant association between filling volume and %TBWL at 6 months (p = 0.268). Higher BFV was associated with lower rates of esophagitis (slope = -0.008, p < 0.001) and prosthesis migration (slope = -0.015, p < 0.001). There was no association between BFV and early removal (p = 0.1), gastroesophageal reflux symptom (p = 0.64), or ulcer rates (p = 0.09). No association was observed between Orbera IGB filling volume and weight loss outcomes. Higher volumes appear to be associated with lower migration and esophagitis rates; thus, a balloon filling volume of 600-650 mL is recommended.

  6. Cerebral flow velocities during daily activities depend on blood pressure in patients with chronic ischemic infarctions

    PubMed Central

    Novak, Vera; Hu, Kun; Desrochers, Laura; Novak, Peter; Caplan, Louis; Lipsitz, Lewis; Selim, Magdy

    2010-01-01

    Background Target blood pressure (BP) values for optimal cerebral perfusion after an ischemic stroke are still debated. We sought to examine the relationship between BP and cerebral blood flow velocities (BFV) during daily activities. Methods We studied 43 patients with chronic large vessel ischemic infarctions in middle cerebral artery (MCA) territory (aged 64.2±8.94 years; at 6.1±4.9 years after stroke), and 67 age-matched controls. BFV in MCAs were measured during supine baseline, sitting, standing and tilt. A regression analysis and a dynamic phase analysis were used to quantify BP-BFV relationship. Results The mean arterial pressure was similar between the groups (89±15 mmHg). Baseline BFV were lower by ~ 30% in the stroke patients compared to the controls (p=0.0001). BFV declined further with postural changes, and remained lower in the stroke group during sitting (p=0.003), standing (p=0.003) and tilt (p=0.002) as compared to the control group. Average BFV on the stroke side were positively correlated with BP during baseline (R=0.54, p=0.0022, the slope 0.46 cm/s/mm Hg) and tilt (R=0.52, p=0.0028, the slope 0.40 cm/s/mm Hg). Regression analysis suggested that BFV may increase ~ 30-50% at mean BP > 100 mmHg. Orthostatic hypotension during the first minute of tilt or standing was independently associated with lower BFV on the stroke side (p=0.0008). Baseline BP-BFV phase shift derived from the phase analysis was smaller on the stroke-side (p=0.0006). Conclusion We found that BFV are lower in stroke patients and daily activities such as standing could induce hypoperfusion. BFV increase with mean arterial pressure > 100 mmHg. Dependency of BFV on arterial pressure may have implications for BP management after stroke. Further prospective investigations are needed to determine the impact of these findings on functional recovery and strategies to improve perfusion pressure during daily activities after ischemic stroke. PMID:19959536

  7. Fully distributed absolute blood flow velocity measurement for middle cerebral arteries using Doppler optical coherence tomography

    PubMed Central

    Qi, Li; Zhu, Jiang; Hancock, Aneeka M.; Dai, Cuixia; Zhang, Xuping; Frostig, Ron D.; Chen, Zhongping

    2016-01-01

    Doppler optical coherence tomography (DOCT) is considered one of the most promising functional imaging modalities for neuro biology research and has demonstrated the ability to quantify cerebral blood flow velocity at a high accuracy. However, the measurement of total absolute blood flow velocity (BFV) of major cerebral arteries is still a difficult problem since it is related to vessel geometry. In this paper, we present a volumetric vessel reconstruction approach that is capable of measuring the absolute BFV distributed along the entire middle cerebral artery (MCA) within a large field-of-view. The Doppler angle at each point of the MCA, representing the vessel geometry, is derived analytically by localizing the artery from pure DOCT images through vessel segmentation and skeletonization. Our approach could achieve automatic quantification of the fully distributed absolute BFV across different vessel branches. Experiments on rodents using swept-source optical coherence tomography showed that our approach was able to reveal the consequences of permanent MCA occlusion with absolute BFV measurement. PMID:26977365

  8. Fully distributed absolute blood flow velocity measurement for middle cerebral arteries using Doppler optical coherence tomography.

    PubMed

    Qi, Li; Zhu, Jiang; Hancock, Aneeka M; Dai, Cuixia; Zhang, Xuping; Frostig, Ron D; Chen, Zhongping

    2016-02-01

    Doppler optical coherence tomography (DOCT) is considered one of the most promising functional imaging modalities for neuro biology research and has demonstrated the ability to quantify cerebral blood flow velocity at a high accuracy. However, the measurement of total absolute blood flow velocity (BFV) of major cerebral arteries is still a difficult problem since it is related to vessel geometry. In this paper, we present a volumetric vessel reconstruction approach that is capable of measuring the absolute BFV distributed along the entire middle cerebral artery (MCA) within a large field-of-view. The Doppler angle at each point of the MCA, representing the vessel geometry, is derived analytically by localizing the artery from pure DOCT images through vessel segmentation and skeletonization. Our approach could achieve automatic quantification of the fully distributed absolute BFV across different vessel branches. Experiments on rodents using swept-source optical coherence tomography showed that our approach was able to reveal the consequences of permanent MCA occlusion with absolute BFV measurement.

  9. Assessment of cerebral blood flow with magnetic resonance imaging in children with sickle cell disease: A quantitative comparison with transcranial Doppler ultrasonography.

    PubMed

    Croal, Paula L; Leung, Jackie; Kosinski, Przemyslaw; Shroff, Manohar; Odame, Isaac; Kassner, Andrea

    2017-11-01

    Transcranial Doppler ultrasonography (TCD) is a clinical tool for stratifying ischemic stroke risk by identifying abnormal elevations in blood flow velocity (BFV) in the middle cerebral artery (MCA). However, TCD is not effective at screening for subtle neurologic injury such as silent cerebral infarcts. To better understand this disparity, we compared TCD measures of BFV with tissue-level cerebral blood flow (CBF) using arterial spin-labeling MRI in children with and without sickle cell disease, and correlated these measurements against clinical hematologic measures of disease severity. TCD and MRI assessment were performed in 13 pediatric sickle cell disease patients and eight age-matched controls. Using MRI measures of MCA diameter and territory weight, TCD measures of BFV in the MCA [cm/s] were converted into units of CBF [ml min -1 100 g -1 ] for comparison. There was no significant association between TCD measures of BFV in the MCA and corresponding MRI measures of CBF in patients ( r  =   .28, p  =   .39) or controls ( r  =   .10, p  =   .81). After conversion from BFV into units of CBF, a strong association was observed between TCD and MRI measures ( r  =   .67, p  =   .017 in patients, r  =   .86, p  =   .006 in controls). While BFV in the MCA showed a lack of correlation with arterial oxygen content, an inverse association was observed for CBF measurements. This study demonstrates that BFV in the MCA cannot be used as a surrogate marker for tissue-level CBF in children with sickle cell disease. Therefore, TCD alone may not be sufficient for understanding and predicting subtle pathophysiology in this population, highlighting the potential clinical value of tissue-level CBF.

  10. Intraocular pressure and superior ophthalmic vein blood flow velocity in Graves' orbitopathy: relation with the clinical features.

    PubMed

    Konuk, Onur; Onaran, Zafer; Ozhan Oktar, Suna; Yucel, Cem; Unal, Mehmet

    2009-11-01

    The aim of this study is to evaluate the association of intraocular pressure (IOP) and superior ophthalmic vein blood flow velocity (SOV-BFV) with the clinical features of Graves' orbitopathy. During the 2002-2007 period, 66 eyes of 34 Graves' orbitopathy cases were classified as mild, moderate and severe orbital disease, and evaluated according to their clinical features as: i)type 1 vs type 2 cases, and ii) cases with or without dysthyroid optic neuropathy. In all patients, a full ophthalmic examination including IOP and Hertel measurements was performed. SOV-BFV was analyzed with color Doppler sonography. The Hertel value, IOP in primary and upgaze position were higher, and SOV-BFV was lower in moderate and severe Graves' orbitopathy cases that showed statistical significance from mild cases, and controls (p = 0.001). Moderate and severe Graves' orbitopathy cases showed comparable Hertel measures and IOP in primary and upgaze position (p = 0.39); however, SOV-BFV was significantly lower in severe cases when compared to moderate cases (p = 0.001).This study demonstrated statistically significant negative correlation between IOP in both primary (r = 0.43,p = 0.008) and upgaze position (r = 0.51,p = 0.002), and SOV-BFV. Additionally, statistically significant positive correlation was detected between Hertel values and SOV-BFV(r = 0.402,p = 0.007).There was a statistical difference between type 1 and 2 cases in Hertel values(p = 0.006), IOP in upgaze position (p = 0.026) and SOV-BFV (p = 0.003). SOV-BFV of the eyes showing dysthyroid optic neuropathy was statistically lower than eyes without dysthyroid optic neuropathy (p = 0.006). IOP and SOV-BFV have significant association with the clinical features of Graves' orbitopathy. The decrease in SOV-BFV increases the severity of Graves' orbitopathy, and may have a role in the clinical course of dysthyroid optic neuropathy.

  11. Developmental changes in cerebral and visceral blood flow velocity in healthy neonates and infants.

    PubMed

    Ilves, Pilvi; Lintrop, Mare; Talvik, Inga; Muug, Külli; Asser, Karin; Veinla, Maie

    2008-02-01

    The purpose of this study was to evaluate the changes in Doppler blood flow velocity (BFV) in cerebral and visceral arteries during infancy. The BFV was measured in 37 healthy term neonates in the anterior cerebral artery (ACA), middle cerebral artery (MCA), basilar artery, internal carotid artery (ICA), celiac artery (CA), superior mesenteric artery (SMA), and renal artery (RA). The mean BFV increased and the resistive index decreased (P < .05) in all cerebral arteries, SMA, and CA by the age of 12 to 23.9 hours and in the RA by the age of 24 to 35.9 hours compared with 2 to 11.9 hours. A further significant increase (P < .05) of the mean BFV occurred in all arteries except the ICA and CA by the age of 72 to 120 hours compared with 12 to 23.9 hours. By the age of 21 to 59 days, the mean BVF doubled in all investigated arteries compared with 2 to 11.9 hours, with a further significant increase (P < .05) by the age of 150 to 240 days in cerebral and renal arteries. There was no correlation between the mean blood pressure (BP) and mean BFV in the ACA and MCA. However, there was a positive correlation (r > or = 0.5; P < .05) between the BP and BFV in the RA and SMA at the age of 12 to 23.9 hours. A significant increase in the cerebral and visceral BFV occurs normally throughout infancy, with the visceral BFV affected by BP changes during the first day of life.

  12. [Age dynamics and seasonal variations of parameters of cerebral circulation in children and adolescents from European north].

    PubMed

    Soroko, S I; Rozhkov, V P

    2014-10-01

    Age dynamics and seasonal variations in cerebral blood flow was studied by means of transcranial Doppler in 95 the natives of the Arkhangelsk region school students aged 7 to 18 years. The results of longitudinal (from 2005 to 2014) study of students are presented. The linear blood flow velocity (BFV) showed gradual declining from junior to senior school age, and BFV were in the middle cerebral artery below average, and in the basilar artery--above mid latitude standards. The influence of the seasonal factor is more pronounced in the younger (for boys) and intermediate (for girls) age group and leveled in the older group. The largest seasonal changes were obtained in BFV in carotid arteries, the relative constancy--in BFV in the basilar artery. Estimated by the resistivity index RI circulatory resistance in the younger and intermediate school students groups decreased in the carotid arteries in the spring and summer, and in the posterior cerebral artery territory--in the winter. BFV rate variability identifies groups of children with varying degrees of "sensitivity" to the influence of seasonal factors.

  13. Linear Algebraic Modeling of Power Flow in the HMPT500-3 Transmission

    DTIC Science & Technology

    2012-08-01

    BFV ) family and Multiple Launch Rocket System (MLRS). It is also proposed for use in the Paladin Integrated Management (PIM) self-propelled...howitzer and BFV derived Armored Multipurpose Vehicle (AMPV). Weight growth of these vehicles is exceeding the capacity of the current HMPT500-3...reduce the heat-rejection burden to the cooling system also makes efficiency improvements desirable. Automotive performance models of the BFV to

  14. Linear Algebraic Modeling of Power Flow in the HMP500-3 Transmission

    DTIC Science & Technology

    2012-08-01

    BFV ) family and Multiple Launch Rocket System (MLRS). It is also proposed for use in the Paladin Integrated Management (PIM) self-propelled...howitzer and BFV derived Armored Multipurpose Vehicle (AMPV). Weight growth of these vehicles is exceeding the capacity of the current HMPT500-3...reduce the heat-rejection burden to the cooling system also makes efficiency improvements desirable. Automotive performance models of the BFV to date

  15. Intraoperative trans-fontanellar cerebral ultrasonography in infants during cardiac surgery under cardiopulmonary bypass: an observational study.

    PubMed

    Park, Yong-Hee; Song, In-Kyung; Lee, Ji-Hyun; Kim, Hee-Soo; Kim, Chong-Sung; Kim, Jin-Tae

    2017-02-01

    This study was performed to evaluate the feasibility of intraoperative point-of-care trans-fontanellar cerebral ultrasonography (TFCU) to obtain blood flow velocity (BFV) reference values at the internal carotid arteries (ICAs) and peri-callosal part of the anterior cerebral artery (pACA) during pediatric cardiac surgery under cardiopulmonary bypass (CPB). TFCU was performed at three time points (after induction of anesthesia, during CPB, after CPB) in 35 infants. BFV was measured at both ICAs and pACA through the anterior fontanelle with an ultrasound sector probe. We divided patients into Group S (<5 kg, n = 16) and Group L (≥5 kg, n = 19) for comparisons according to weight. We also analyzed BFV in low cerebral regional oxygen saturation (rSO 2 ) data. All measurements of the BFV at both the ICAs and the pACA were possible. BFVs at the ICAs were lower in Group S than in Group L at all three time points. BFVs at the pACA were similar in both groups except higher value in Group L after CPB. When the rSO 2 was <50, most BFVs (14 of 15 measurements) were lower than the median BFV value during CPB. However, a low rSO 2 did not always reflect low BFV before and after CPB. Point-of-care TFCU can determine BFV at the ICAs and pACA during pediatric cardiac surgery. BFV differs according to the patient's size and CPB application. TFCU can be a practical cerebral blood flow monitoring method when rSO 2 changes without any specific reason in infants.ClinicalTrials.gov NCT01996020.

  16. Effects of ischemic stroke on dynamics of cerebral autoregulation

    NASA Astrophysics Data System (ADS)

    Chen, Zhi; Ivanov, Plamen Ch; Hu, Kun; Stanley, Eugene; Novak, Vera

    2004-03-01

    Cerebral vasoregulation involves several complex mechanisms adapting blood flow to fluctuations of systemic blood pressure (BP). Autonomic BP and metabolic vasoregulation are impaired after stroke and cerebral blood flow depends on systemic BP. To probe the mechanisms of cerebral autoregulation we study levels of nonlinear synchronization between cerebral blood flow velocity (BFV) and peripheral BP. We quantify the instantaneous phase of each signal employing analytic signal approach and Hilbert transform. As a marker of synchronization, we introduce a measure of cross-correlation between the instantaneous phase increments of the BFV and BP signals at different time lags. We have studied 12 subjects with minor chronic ischemic stroke and 11 matched normotensive controls (age<65years). BFV and BP of these subjects are continuously recorded during supine baseline, head-up tilt, hyperventilation and CO2 rebreathing. For control subjects we find significant synchronization between cerebral BFV and peripheral BP only for short time lags of up to 5-6 seconds, suggesting a rapid return to a steady cerebral blood flow after initial blood pressure perturbations. In contrast, for stroke subjects BFV/BP we find enhanced synchronization over longer time lags of up to 20 seconds, suggesting entrainment of cerebral blood flow velocity by slow vasomotor rhythms. These findings suggest that cerebral vasoregulation is impaired and cerebral blood flow follows the fluctuations of systemic BP in a synchronous manner. Our analysis shows that cerebral autoregulation is impaired in 10 out of the 12 stroke subjects, which is typically difficult to diagnose with conventional methods. Thus, our novel synchronization approach offers a new tool sensitive for evaluation of changes in the dynamics of cerebral autoregulation under stroke.

  17. Macular microcirculation in hypertensive patients with and without branch retinal vein occlusion.

    PubMed

    Noma, Hidetaka; Funatsu, Hideharu; Sakata, Kumi; Harino, Seiyo; Mimura, Tatsuya; Hori, Sadao

    2009-09-01

    Our purpose was to determine whether a reduction in blood flow velocity (BFV) in the perifoveal capillaries is involved in the pathogenesis of branch retinal vein occlusion (BRVO) in patients with hypertension. Subjects included hypertensive patients with (n = 12) and without (n = 16) BRVO and healthy volunteers (n = 16). Perifoveal BFV was measured by the tracing method using fluorescein angiography and a scanning laser ophthalmoscope. Logistic regression analysis was performed to assess factors that influenced the presence or absence of BRVO. Mean BFV showed a significant decrease across the three groups (healthy controls: 1.49 +/- 0.11 mm/second; hypertensive patients without BRVO: 1.36 +/- 0.12 mm/second; hypertensive patients with BRVO: 1.16 +/- 0.24 mm/second; p(trend) < 0.001). Multivariate logistic regression analysis showed that BFV was a significant risk factor for the presence of BRVO. Perifoveal capillary BFV is reduced in hypertensive patients with and without BRVO. It is possible that a decrease in BFV may be involved in the occurrence of BRVO. Measurement of perifoveal capillary BFV may be useful for investigating the pathogenesis and progression of BRVO.

  18. Changes in cerebral and visceral blood flow velocities in asphyxiated term neonates with hypoxic-ischemic encephalopathy.

    PubMed

    Ilves, Pilvi; Lintrop, Mare; Talvik, Inga; Muug, Külli; Maipuu, Lea

    2009-11-01

    The purpose of this study was to evaluate changes in the Doppler blood flow velocity (BFV) in the cerebral and visceral arteries in asphyxiated term neonates. The BFV was measured in 47 asphyxiated and 37 healthy term neonates in the anterior cerebral artery, middle cerebral artery, basilar artery, internal carotid artery, celiac artery (CA), superior mesenteric artery (SMA), and renal artery (RA) up to the age of 60 to 149 days. At the age of 12 to 120 hours after asphyxia, the mean BFV had increased, and the resistive index (RI) had decreased (P < .05) in all cerebral arteries in neonates with severe hypoxic-ischemic encephalopathy (HIE) compared with the control group. In neonates with severe HIE, the mean BFV in the RA had significantly decreased at the age of 3 to 240 hours, and the RI had increased at the age of 24 to 240 hours, normalizing by the age of 21 to 59 days compared with the control group (P < .05). In the SMA, a decreased mean BFV was found in neonates with severe HIE compared with those with mild to moderate HIE only at the age of 24 to 36 hours. In neonates with mild to moderate HIE, the mean BFV had increased in the SMA and CA compared with the control group at the age of 2 to 11.9 hours. A severe alteration of the cerebral and visceral BFV takes place during the first days after asphyxia in neonates with different severities of HIE.

  19. Cerebral blood flow regulation during cognitive tasks

    PubMed Central

    Sorond, Farzaneh A.; Schnyer, D.M.; Serrador, J.M.; Milberg, W.P.; Lipsitz, L.A.

    2008-01-01

    Aging is associated with frontal subcortical microangiopathy and executive cognitive dysfunction, suggesting that elderly individuals may have impaired metabolic activation of cerebral blood flow to the frontal lobes. We used transcranial Doppler (TCD) ultrasound to examine the cerebral blood flow response to executive control and visual tasks in the anterior and posterior cerebral circulations and to determine the effects of healthy aging on cerebral blood flow regulation during cognitive tasks. Continuous simultaneous anterior cerebral artery (ACA) and posterior cerebral artery (PCA) blood flow velocities (BFVs) and mean arterial pressure (MAP) were measured in response to word stem completion (WSC) and a visual search (VS) task in 29 healthy subjects (14 young, 30 ± 1.5 years; 15 old, 74 ± 1.4 years). We found that: (1) ACA and PCA blood flow velocities are both significantly increased during WSC and VS cognitive tasks, (2) ACA and PCA activations were task specific in our young volunteers, with ACA > PCA BFV during the WSC task and PCA > ACA BFV during the VS task, (3) while healthy elderly subjects also had PCA > ACA BFV during the VS task, they did not have ACA > PCA activation during the WSC task, and (4) healthy elderly subjects tend to have overall greater increases in BFV during both cognitive tasks. We conclude that TCD can be used to monitor cerebrovascular hemodynamics during the performance of cognitive tasks. Our data suggest that there is differential blood flow increase in the ACA and PCA in young versus elderly subjects during cognitive tasks. PMID:18387547

  20. Hemodynamic monitoring of middle cerebral arteries during cognitive tasks performance.

    PubMed

    Boban, Marina; Črnac, Petra; Junaković, Anamari; Malojčić, Branko

    2014-11-01

    The aim of this study was to obtain temporal pattern and hemispheric dominance of blood flow velocity (BFV) changes and to assess suitability of different cognitive tasks for monitoring of BFV changes in the middle cerebral arteries (MCA). BFV were recorded simultaneously in MCA during performance of phonemic verbal fluency test (pVFT), Trail Making Tests A and B (TMTA and TMTB) and Stroop tests in 14 healthy, right-handed volunteers aged 20-26 years. A significant increase of BFV in both MCA was obtained during performance of all cognitive tasks. Statistically significant lateralization was found during performance of Stroop test with incongruent stimuli, while TMTB was found to have the best activation potential for MCA. Our findings specify TMTB as the most suitable cognitive test for monitoring of BFV in MCA. © 2014 The Authors. Psychiatry and Clinical Neurosciences © 2014 Japanese Society of Psychiatry and Neurology.

  1. Cross-correlation of instantaneous phase increments in pressure-flow fluctuations: Applications to cerebral autoregulation

    NASA Astrophysics Data System (ADS)

    Chen, Zhi; Hu, Kun; Stanley, H. Eugene; Novak, Vera; Ivanov, Plamen Ch.

    2006-03-01

    We investigate the relationship between the blood flow velocities (BFV) in the middle cerebral arteries and beat-to-beat blood pressure (BP) recorded from a finger in healthy and post-stroke subjects during the quasisteady state after perturbation for four different physiologic conditions: supine rest, head-up tilt, hyperventilation, and CO2 rebreathing in upright position. To evaluate whether instantaneous BP changes in the steady state are coupled with instantaneous changes in the BFV, we compare dynamical patterns in the instantaneous phases of these signals, obtained from the Hilbert transform, as a function of time. We find that in post-stroke subjects the instantaneous phase increments of BP and BFV exhibit well-pronounced patterns that remain stable in time for all four physiologic conditions, while in healthy subjects these patterns are different, less pronounced, and more variable. We propose an approach based on the cross-correlation of the instantaneous phase increments to quantify the coupling between BP and BFV signals. We find that the maximum correlation strength is different for the two groups and for the different conditions. For healthy subjects the amplitude of the cross-correlation between the instantaneous phase increments of BP and BFV is small and attenuates within 3-5 heartbeats. In contrast, for post-stroke subjects, this amplitude is significantly larger and cross-correlations persist up to 20 heartbeats. Further, we show that the instantaneous phase increments of BP and BFV are cross-correlated even within a single heartbeat cycle. We compare the results of our approach with three complementary methods: direct BP-BFV cross-correlation, transfer function analysis, and phase synchronization analysis. Our findings provide insight into the mechanism of cerebral vascular control in healthy subjects, suggesting that this control mechanism may involve rapid adjustments (within a heartbeat) of the cerebral vessels, so that BFV remains steady in response to changes in peripheral BP.

  2. Cross-correlation of instantaneous phase increments in pressure-flow fluctuations: applications to cerebral autoregulation.

    PubMed

    Chen, Zhi; Hu, Kun; Stanley, H Eugene; Novak, Vera; Ivanov, Plamen Ch

    2006-03-01

    We investigate the relationship between the blood flow velocities (BFV) in the middle cerebral arteries and beat-to-beat blood pressure (BP) recorded from a finger in healthy and post-stroke subjects during the quasisteady state after perturbation for four different physiologic conditions: supine rest, head-up tilt, hyperventilation, and CO2 rebreathing in upright position. To evaluate whether instantaneous BP changes in the steady state are coupled with instantaneous changes in the BFV, we compare dynamical patterns in the instantaneous phases of these signals, obtained from the Hilbert transform, as a function of time. We find that in post-stroke subjects the instantaneous phase increments of BP and BFV exhibit well-pronounced patterns that remain stable in time for all four physiologic conditions, while in healthy subjects these patterns are different, less pronounced, and more variable. We propose an approach based on the cross-correlation of the instantaneous phase increments to quantify the coupling between BP and BFV signals. We find that the maximum correlation strength is different for the two groups and for the different conditions. For healthy subjects the amplitude of the cross-correlation between the instantaneous phase increments of BP and BFV is small and attenuates within 3-5 heartbeats. In contrast, for post-stroke subjects, this amplitude is significantly larger and cross-correlations persist up to 20 heartbeats. Further, we show that the instantaneous phase increments of BP and BFV are cross-correlated even within a single heartbeat cycle. We compare the results of our approach with three complementary methods: direct BP-BFV cross-correlation, transfer function analysis, and phase synchronization analysis. Our findings provide insight into the mechanism of cerebral vascular control in healthy subjects, suggesting that this control mechanism may involve rapid adjustments (within a heartbeat) of the cerebral vessels, so that BFV remains steady in response to changes in peripheral BP.

  3. Comparison of phase-contrast MR imaging and endovascular sonography for intracranial blood flow velocity measurements.

    PubMed

    Schneiders, J J; Ferns, S P; van Ooij, P; Siebes, M; Nederveen, A J; van den Berg, R; van Lieshout, J; Jansen, G; vanBavel, E; Majoie, C B

    2012-10-01

    Local hemodynamic information may help to stratify rupture risk of cerebral aneurysms. Patient-specific modeling of cerebral hemodynamics requires accurate data on BFV in perianeurysmal arteries as boundary conditions for CFD. The aim was to compare the BFV measured with PC-MR imaging with that obtained by using intra-arterial Doppler sonography and to determine interpatient variation in intracranial BFV. In 10 patients with unruptured intracranial aneurysms, BFV was measured in the cavernous ICA with PC-MR imaging in conscious patients before treatment, and measured by using an intra-arterial Doppler sonography wire when the patient was anesthetized with either propofol (6 patients) or sevoflurane (4 patients). Both techniques identified a pulsatile blood flow pattern in cerebral arteries. PSV differed >50 cm/s between patients. A mean velocity of 41.3 cm/s (95% CI, 39.3-43.3) was measured with PC-MR imaging. With intra-arterial Doppler sonography, a mean velocity of 29.3 cm/s (95% CI, 25.8-32.8) was measured with the patient under propofol-based intravenous anesthesia. In patients under sevoflurane-based inhaled anesthesia, a mean velocity of 44.9 cm/s (95% CI, 40.6-49.3) was measured. We showed large differences in BFV between patients, emphasizing the importance of using patient-specific hemodynamic boundary conditions in CFD. PC-MR imaging measurements of BFV in conscious patients were comparable with those obtained with the intra-arterial Doppler sonography when the patient was anesthetized with a sevoflurane-based inhaled anesthetic.

  4. Relationships Among Cognitive Function and Cerebral Blood Flow, Oxidative Stress, and Inflammation in Older Heart Failure Patients.

    PubMed

    Kure, Christina E; Rosenfeldt, Franklin L; Scholey, Andrew B; Pipingas, Andrew; Kaye, David M; Bergin, Peter J; Croft, Kevin D; Wesnes, Keith A; Myers, Stephen P; Stough, Con

    2016-07-01

    The mechanisms for cognitive impairment in heart failure (HF) are unclear. We investigated the relative contributions of cerebral blood flow velocity (BFV), oxidative stress, and inflammation to HF-associated cognitive impairment. Thirty-six HF patients (≥60 years) and 40 healthy controls (68 ± 7 vs 67 ± 5 years, P > .05; 69% vs 50% male, P > .05) completed the Cognitive Drug Research computerized assessment battery and Stroop tasks. Common carotid (CCA) and middle cerebral arterial BFV were obtained by transcranial Doppler. Blood samples were collected for oxidant (diacron-reactive oxygen metabolites; F2-isoprostanes), antioxidant (coenzyme Q10; CoQ10), and inflammatory markers (high-sensitivity C-reactive protein). Compared with controls, patients exhibited impaired attention (Cognitive Drug Research's Power of Attention domain, congruent Stroop) and executive function (incongruent Stroop). Multiple regression modeling showed that CCA-BFV and CoQ10 but not group predicted performance on attention and executive function. Additionally, in HF patients, CCA-BFV and CoQ10 (β = -0.34 vs β = -0.35) were significant predictors of attention, and CCA-BFV (β = -0.34) was a predictor of executive function. Power of Attention and executive function is impaired in older HF patients, and reduced CCA-BFV and CoQ10 are associated with worse cognition. Interventions addressing these mechanisms may improve cognition in older HF patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. A new visually evoked cerebral blood flow response analysis using a low-frequency estimation.

    PubMed

    Rey, Beatriz; Naranjo, Valery; Parkhutik, Vera; Tembl, José; Alcañiz, Mariano

    2010-03-01

    Transcranial Doppler (TCD) has been widely used to monitor cerebral blood flow velocity (BFV) during the performance of cognitive tasks compared with repose periods. Although one of its main advantages is its high temporal resolution, only some of the previous functional TCD studies have focused on the analysis of the temporal evolution of the BFV signal and none of them has performed a spectral analysis of the signal. In this study, maximum BFV data in both posterior cerebral arteries was monitored during a visual perception task (10 cycles of alternating darkness and illumination) for 23 subjects. A peak was located in the low-frequency band of the spectrum of the maximum BFV of each subject both during visual stimulation and repose periods. The frequency of this peak was in the range between 0.037 and 0.098Hz, depending on the subject, the vessel and the experimental condition. The component of the signal at this frequency, which is associated with the slow variations caused by the visual stimuli, was estimated. That way, the variations in BFV caused by the experimental stimuli were isolated from the variations caused by other factors. This low-frequency estimation signal was used to obtain parameters about the temporal evolution and the magnitude variations of the BFV in a reliable way, thus, characterizing the neurovascular coupling of the participants. Copyright 2010 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  6. Effect of microbubble contrast on intracranial blood flow velocity assessed by transcranial Doppler.

    PubMed

    Logallo, Nicola; Fromm, Annette; Waje-Andreassen, Ulrike; Thomassen, Lars; Matre, Knut

    2014-03-01

    Ultrasound contrast agents (UCA) salvage a considerable number of transcranial Doppler (TCD) exams which would have failed because of poor bone window. UCA bolus injection causes an undesirable increase in measured blood flow velocity (BFV). The effect of UCA continuous infusion on measured BFV has not been investigated, and some in vitro experiments suggest that gain reduction during UCA administration may also influence measured BFV. This study aimed to investigate the effect of UCA continuous infusion on BFV measured by TCD and the influence of gain reduction on these measurements in a clinical setting. The right middle cerebral artery of ten patients with optimal bone window was insonated using a 2 MHz probe. UCA were administered using an infusion pump. BFV was measured (1) at baseline, (2) during UCA infusion, (3) during UCA infusion with gain reduction, and (4) after UCA wash-out phase. Gain reduction was based on the agreement between two neurosonographers on the degree of gain reduction necessary to restore baseline Doppler signal intensity (DSI). Actual DSI was estimated offline by analysis of raw data. BFV measured during UCA infusion with no gain adjustment was significantly higher than baseline BFV [peak systolic velocity (PSV): 85.1 ± 19.7 vs. 74.4 ± 19.7 cm/s, p < 0.0001; Mean velocity (MV): 56.5 ± 11.8 vs. 50.2 ± 12.3 cm/s, p < 0.0001]. BFV measured during UCA infusion with gain reduction was not significantly higher than baseline BFV (PSV: 74.3 ± 18.9 vs. 74.4 ± 19.4 cm/s, p = 0.8; MV: 49.4 ± 11.0 vs. 50.2 ± 12.3 cm/s, p = 0.8). Actual DSI during UCA infusion with gain reduction was not significantly higher than baseline DSI (13 ± 1 vs. 13 ± 1 dB). This study shows that UCA continuous infusion leads to an increase in measured BFV which may be counteracted by reducing Doppler gain thus restoring pre-contrast DSI.

  7. Interactive retinal blood flow analysis of the macular region.

    PubMed

    Tian, Jing; Somfai, Gábor Márk; Campagnoli, Thalmon R; Smiddy, William E; Debuc, Delia Cabrera

    2016-03-01

    The study of retinal hemodynamics plays an important role to understand the onset and progression of diabetic retinopathy. In this work, we developed an interactive retinal analysis tool to quantitatively measure the blood flow velocity (BFV) and blood flow rate (BFR) in the macular region using the Retinal Function Imager (RFI). By employing a high definition stroboscopic fundus camera, the RFI device is able to assess retinal blood flow characteristics in vivo. However, the measurements of BFV using a user-guided vessel segmentation tool may induce significant inter-observer differences and BFR is not provided in the built-in software. In this work, we have developed an interactive tool to assess the retinal BFV and BFR in the macular region. Optical coherence tomography data was registered with the RFI image to locate the fovea accurately. The boundaries of the vessels were delineated on a motion contrast enhanced image and BFV was computed by maximizing the cross-correlation of pixel intensities in a ratio video. Furthermore, we were able to calculate the BFR in absolute values (μl/s). Experiments were conducted on 122 vessels from 5 healthy and 5 mild non-proliferative diabetic retinopathy (NPDR) subjects. The Pearson's correlation of the vessel diameter measurements between our method and manual labeling on 40 vessels was 0.984. The intraclass correlation (ICC) of BFV between our proposed method and built-in software was 0.924 and 0.830 for vessels from healthy and NPDR subjects, respectively. The coefficient of variation between repeated sessions was reduced significantly from 22.5% to 15.9% in our proposed method (p<0.001). Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Macular microcirculation in patients with epiretinal membrane before and after surgery.

    PubMed

    Yagi, Tomoko; Sakata, Kumi; Funatsu, Hideharu; Noma, Hidetaka; Yamamoto, Kaori; Hori, Sadao

    2012-06-01

    To investigate blood flow velocity (BFV) in the perifoveal capillaries before and after vitreous surgery for patients with epiretinal membrane (ERM). Twenty-one eyes in patients with ERM and 16 eyes in healthy subjects were involved in this study. Fluorescein angiography was performed using a scanning laser ophthalmoscope and BFV was analyzed by the tracing method. Foveal thickness (FT) was measured by optical coherence tomography. BFV was significantly slower in the ERM patients (1.04 ± 0.10 mm/s) than in the healthy subjects (1.49 ± 0.11 mm/s ) (p = 0.0010). BFV in the ERM patients 6 months after vitreous surgery (6 M) (1.21 ± 0.02 mm/s) significantly increased compared with BFV before surgery (0 M) (1.04 ± 0.10 mm/s) (p = 0.0061). BFV 1 year after vitreous surgery (1 Y) significantly increased (1.38 ± 0.02 mm/s) compared with BFV(6 M) (1.21 ± 0.02 mm/s) (p = 0.0235). FT was significantly greater in the ERM patients (351.7 ± 87.1 μm) than in the healthy subjects (158.9 ± 16.9 μm) (p = 0.0011). FT (6 M) significantly decreased (285.3 ± 36.9 μm) compared with FT before surgery (0 M) (351.7 ± 87.1 μm) (p = 0.0212). FT did not show significant differences between (6 M) and (1 Y). No significant correlation was found between BFV and FT before surgery. Perifoveal capillary BFV in patients with ERM was slower than that in the healthy subjects, and significantly improved after vitreous surgery as time progressed. It can be said that perifoveal capillary BFV is related to the development and improvement of ERM in the long term.

  9. Evaluating endothelial function of the common carotid artery: an in vivo human model.

    PubMed

    Mazzucco, S; Bifari, F; Trombetta, M; Guidi, G C; Mazzi, M; Anzola, G P; Rizzuto, N; Bonadonna, R

    2009-03-01

    Flow mediated dilation (FMD) of peripheral conduit arteries is a well-established tool to evaluate endothelial function. The aims of this study are to apply the FMD model to cerebral circulation by using acetazolamide (ACZ)-induced intracranial vasodilation as a stimulus to increase common carotid artery (CCA) diameter in response to a local increase of blood flow velocity (BFV). In 15 healthy subjects, CCA end-diastolic diameter and BFV, middle cerebral artery (MCA) BFV and mean arterial blood pressure (MBP) were measured at basal conditions, after an intravenous bolus of 1g ACZ, and after placebo (saline) sublingual administration at the 15th and 20th minute. In a separate session, the same parameters were evaluated after placebo (saline) infusion instead of ACZ and after 10 microg/m(2) bs and 300 microg of glyceryl trinitrate (GTN), administered sublingually, at the 15th and 20th minute, respectively. After ACZ bolus, there was a 35% maximal MCA mean BFV increment (14th minute), together with a 22% increase of mean CCA end-diastolic BFV and a CCA diameter increment of 3.9% at the 3rd minute (p=0.024). There were no MBP significant variations up to the 15th minute (p=0.35). After GTN administration, there was a significant increment in CCA diameter (p<0.00001). ACZ causes a detectable CCA dilation in healthy individuals concomitantly with an increase in BFV. Upon demonstration that this phenomenon is endothelium dependent, this experimental model might become a valuable tool to assess endothelial function in the carotid artery.

  10. Multimodal Pressure Flow Analysis: Application of Hilbert Huang Transform in Cerebral Blood Flow Regulation

    PubMed Central

    Lo, Men-Tzung; Hu, Kun; Liu, Yanhui; Peng, C.-K.; Novak, Vera

    2008-01-01

    Quantification of nonlinear interactions between two nonstationary signals presents a computational challenge in different research fields, especially for assessments of physiological systems. Traditional approaches that are based on theories of stationary signals cannot resolve nonstationarity-related issues and, thus, cannot reliably assess nonlinear interactions in physiological systems. In this review we discuss a new technique “Multi-Modal Pressure Flow method (MMPF)” that utilizes Hilbert-Huang transformation to quantify dynamic cerebral autoregulation (CA) by studying interaction between nonstationary cerebral blood flow velocity (BFV) and blood pressure (BP). CA is an important mechanism responsible for controlling cerebral blood flow in responses to fluctuations in systemic BP within a few heart-beats. The influence of CA is traditionally assessed from the relationship between the well-pronounced systemic BP and BFV oscillations induced by clinical tests. Reliable noninvasive assessment of dynamic CA, however, remains a challenge in clinical and diagnostic medicine. In this brief review we: 1) present an overview of transfer function analysis (TFA) that is traditionally used to quantify CA; 2) describe the a MMPF method and its modifications; 3) introduce a newly developed automatic algorithm and engineering aspects of the improved MMPF method; and 4) review clinical applications of MMPF and its sensitivity for detection of CA abnormalities in clinical studies. The MMPF analysis decomposes complex nonstationary BP and BFV signals into multiple empirical modes adaptively so that the fluctuations caused by a specific physiologic process can be represented in a corresponding empirical mode. Using this technique, we recently showed that dynamic CA can be characterized by specific phase delays between the decomposed BP and BFV oscillations, and that the phase shifts are significantly reduced in hypertensive, diabetics and stroke subjects with impaired CA. In addition, the new technique enables reliable assessment of CA using both data collected during clinical test and spontaneous BP/BFV fluctuations during baseline resting conditions. PMID:18725996

  11. Comparison of Retinal Microvessel Blood Flow Velocities Acquired with Two Different Fields of View.

    PubMed

    Zhou, Jin; Li, Min; Chen, Wan; Yang, Ye; Hu, Liang; Wang, Liang; Jiang, Hong; Wang, Jianhua

    2017-01-01

    To compare the different retinal blood flow velocities (BFVs) acquired with different fields of view (FOVs) using the retinal function imager (RFI), twenty eyes of twenty healthy subjects were enrolled in the study. Retinal microvessel BFV in the macula was acquired with both a wide FOV (35 degrees, 7.3 × 7.3 mm 2 ) and a commonly used small FOV (20 degrees, 4.3 × 4.3 mm 2 ). The 35-degree FOV was trimmed to be equivalent to the 20-degree FOV to compare the BFVs of the similar FOVs using different settings. With the 35-degree FOV, both retinal arteriolar and venular BFVs were significantly greater than the 20-degree FOV ( P < 0.001). When the 20-degree FOV was compared to the trimmed equivalent 20-degree FOV acquired using the 35-degree FOV, significant BFV differences were found in both the arterioles ( P = 0.029) and venules ( P < 0.001). This is the first study to compare retinal blood flow velocities acquired with different FOVs using RFI. The conversion factor from 35 degrees to 20 degrees is 0.95 for arteriolar BFV and 0.92 for venular BFV, which may be used for comparing BFVs acquired with different FOVs.

  12. Comparison of Retinal Microvessel Blood Flow Velocities Acquired with Two Different Fields of View

    PubMed Central

    Zhou, Jin; Chen, Wan; Yang, Ye; Hu, Liang; Wang, Liang

    2017-01-01

    To compare the different retinal blood flow velocities (BFVs) acquired with different fields of view (FOVs) using the retinal function imager (RFI), twenty eyes of twenty healthy subjects were enrolled in the study. Retinal microvessel BFV in the macula was acquired with both a wide FOV (35 degrees, 7.3 × 7.3 mm2) and a commonly used small FOV (20 degrees, 4.3 × 4.3 mm2). The 35-degree FOV was trimmed to be equivalent to the 20-degree FOV to compare the BFVs of the similar FOVs using different settings. With the 35-degree FOV, both retinal arteriolar and venular BFVs were significantly greater than the 20-degree FOV (P < 0.001). When the 20-degree FOV was compared to the trimmed equivalent 20-degree FOV acquired using the 35-degree FOV, significant BFV differences were found in both the arterioles (P = 0.029) and venules (P < 0.001). This is the first study to compare retinal blood flow velocities acquired with different FOVs using RFI. The conversion factor from 35 degrees to 20 degrees is 0.95 for arteriolar BFV and 0.92 for venular BFV, which may be used for comparing BFVs acquired with different FOVs. PMID:28758031

  13. Improvement in Cerebral and Ocular Hemodynamics Early after Carotid Endarterectomy in Patients of Severe Carotid Artery Stenosis with or without Contralateral Carotid Occlusion.

    PubMed

    Wang, Jian; Wang, Weici; Jin, Bi; Zhang, Yanrong; Xu, Ping; Xiang, Feixiang; Zheng, Yi; Chen, Juan; Sheng, Shi; Ouyang, Chenxi; Li, Yiqing

    2016-01-01

    Purpose. To investigate the alternation in cerebral and ocular blood flow velocity (BFV) in patients of carotid stenosis (CS) with or without contralateral carotid occlusion (CO) early after carotid endarterectomy (CEA). Patients and Methods. Nineteen patients underwent CEA for ≥50% CS. Fourteen patients had the unilateral CS, and five patients had the ipsilateral CS and the contralateral CO. Transcranial Doppler (TCD) and Color Doppler Imaging (CDI) were performed before and early after CEA. Results. In patients with unilateral CS, significant improvements in BFV were observed in anterior cerebral artery (ACA) and middle cerebral artery (MCA) on the ipsilateral side after CEA. In patients of ipsilateral CS and contralateral CO, significant improvements in BFV were observed in the ACA and MCA not only on the ipsilateral side but also on the contralateral side postoperatively. The ipsilateral ophthalmic artery (OA) retrograde flows in two patients were recovered to anterograde direction following CEA. The BFV in short posterior ciliary artery (SPCA) of the ipsilateral side significantly increased postoperatively irrespective of the presence of contralateral CO. Conclusions. CEA improved cerebral anterior circulation hemodynamics especially in patients of unilateral CS and contralateral CO, normalized the OA reverse flow, and increased the blood perfusion of SPCA.

  14. Placental inflammation and fetal hemodynamics in a rat model of chorioamnionitis.

    PubMed

    Abdulkadir, Adegboyega A; Kimimasa, Tobita; Bell, Michael J; Macpherson, Trevor A; Keller, Bradley B; Yanowitz, Toby D

    2010-12-01

    The relative contributions of inflammation and ischemia to the pathogenesis of periventricular leukomalacia (PVL) have not been elucidated. We hypothesized that fetal cardiovascular function and cerebral blood flow velocity (BFV) would be decreased in a rat model of chorioamnionitis. We also tested whether placental inflammation was related to proximity to the cervix in our model of chorioamnionitis [intracervical lipopolysaccharide (LPS) or vehicle (PBS) injection]. On embryonic d 15, Sprague-Dawley rats underwent baseline maternal and fetal echocardiography, followed by LPS or PBS injection, then serial echocardiographic evaluations until embryonic day (ED) 21. One hour after birth, pups had middle cerebral artery (MCA) BFV measured. Placentas of LPS-exposed pups exhibited uniform, higher inflammation grades (p < 0.001). All fetal BFVs increased with advancing GA (p < 0.001) whereas resistance index (RI) decreased (p < 0.001). There was no difference in fetal BFV between the groups other than a reduced gestation-related increase in descending aorta BFV in LPS-exposed rats (p < 0.05). Newborn pups exposed to LPS had lower heart rate (p = 0.006) and MCA BFV (p = 0.024) and higher RI (p = 0.003) and pulsatility index (PI; p = 0.004). In conclusion, intracervical LPS injection produces an inflammation independent of placental position, a blunted increase in gestation-related aortic BFV, and a decrease in MCA BFV in newborn pups.

  15. An Exploratory Study of Autonomic Function Investigations in Hemophiliacs on Homoeopathy Medications Using Impedance Plethysmography.

    PubMed

    Kundu, Tapas K; Barde, Pradip B; Jindal, Ghanshyam D; Motiwala, Farooq F

    2017-10-01

    Status of autonomic homoeostasis in hemostasic disturbances due to hemophilia needs to be studied. To compare autonomic nervous system markers measured by heart rate variability (HRV) and blood flow variability (BFV) in hemophiliacs and healthy age-matched control population using medical analyzer system. Cross-sectional study. Motiwala Homoeopathy Medical College, and Hemophilia Clinics, Nashik. Eighty subjects. Nil. Autonomic function markers for HRV and BFV. Among 80 subjects, BFV time domain measure, root mean square of successive NN (normal-to-normal) interval differences (RMSSD), was significantly higher among hemophiliacs than nonhemophiliacs. Frequency domain analysis parameter, low frequency for both HRV and BFV was significantly higher among hemophiliacs as compared with nonhemophiliacs. Hemophiliacs were shown to have higher autonomic activity as compared with healthy controls. Homoeopathic medicines used as an adjunct was associated with decrease in parasympathetic modulations.

  16. Neuronavigated microvascular Doppler sonography for intraoperative monitoring of blood flow velocity changes during aneurysm surgery - a feasible monitoring technique.

    PubMed

    Malinova, Vesna; von Eckardstein, Kajetan; Rohde, Veit; Mielke, Dorothee

    2015-10-01

    The intraoperative microvascular Doppler sonography (iMDS) is a well-established tool in vascular surgery for blood flow velocity (BFV) monitoring, capable of detecting vessel occlusion. However, identification of subtotal vessel compromise is more difficult, since the measured BFV may substantially vary with changing insonation angles and insonated vessel segments. To keep these parameters constant we combined neuronavigation with iMDS (niMDS). The question was if niMDS allows the detection of subtotal vessel compromise in aneurysm surgery. During surgery, the 3-dimensional reconstruction of the CT-angiography, which was obtained routinely prior to surgery, was displayed by the neuronavigational system. Prior to clipping, neuronavigation was used to define target point and trajectory, which, by coupling the neuronavigational pointer with the Doppler probe, correspond to the insonated vessel segment and the insonation angle. After clipping, for each vessel segment, the same trajectory was used for all consecutive measurements. The mean BFVs pre- and post-clipping were documented. We performed 82 BFV-measurements in 39 aneurysm surgeries. Mean deviation between pre- and post-clipping BFV values was 2.12cm/s. There was a significant correlation between the mean BFV values before and after clipping (r=0.45 [95% CI 17-66%]; p=0.002). One patient experienced new neurological deficits due to occlusion of a perforating vessel that was not insonated. The study could not answer the question if niMDS can detect BFV changes after clipping indicating vessel compromise, as no subtotal vessel occlusion occurred in the 39 operations. However, we proofed that niMDS-measured BFVs only varied minimally in uncompromised vessels pre- and post-clipping, suggesting that vessel compromises might be easily detected during aneurysm surgery. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Interactive Retinal Blood Flow Analysis of the Macular Region

    PubMed Central

    Tian, Jing; Somfai, Gábor Márk; Campagnoli, Thalmon R.; Smiddy, William E.; Debuc, Delia Cabrera

    2015-01-01

    The study of retinal hemodynamics plays an important role to understand the onset and progression of diabetic retinopathy which is a leading cause of blindness in American adults. In this work, we developed an interactive retinal analysis tool to quantitatively measure the blood flow velocity (BFV) and blood flow rate (BFR) in the macular region using the Retinal Function Imager (RFI-3005, Optical Imaging, Rehovot, Israel). By employing a high definition stroboscopic fundus camera, the RFI device is able to assess retinal blood flow characteristics in vivo even in the capillaries. However, the measurements of BFV using a user-guided vessel segmentation tool may induce significant inter-observer differences and BFR is not provided in the built-in software. In this work, we have developed an interactive tool to assess the retinal BFV as well as BFR in the macular region. Optical coherence tomography (OCT) data from commercially available devices were registered with the RFI image to locate the fovea accurately. The boundaries of the vessels were delineated on a motion contrast enhanced image and BFV was computed by maximizing the cross-correlation of pixel intensities in a ratio video. Furthermore, we were able to calculate the BFR in absolute values (μl/s) which other currently available devices targeting the retinal microcirculation are not yet capable of. Experiments were conducted on 122 vessels from 5 healthy and 5 mild non-proliferative diabetic retinopathy (NPDR) subjects. The Pearson's correlation of the vessel diameter measurements between our method and manual labeling on 40 vessels was 0.984. The intraclass correlation (ICC) of BFV between our proposed method and built-in software were 0.924 and 0.830 for vessels from healthy and NPDR subjects, respectively. The coefficient of variation between repeated sessions was reduced significantly from 22.5% in the RFI built-in software to 15.9% in our proposed method (p<0.001). PMID:26569349

  18. Effect of caffeine on superior mesenteric artery blood flow velocities in preterm neonates.

    PubMed

    Abdel Wahed, Mohamed A; Issa, Hanan M; Khafagy, Soha M; Abdel Raouf, Shaimaa M

    2017-09-22

    To investigate the effect of caffeine infusion on superior mesenteric artery (SMA) blood flow velocities (BFV) in preterm infants. Prospective observational study on 38 preterm neonates 28-33 +6 weeks gestation, who developed apnea on their first day of life, and caffeine citrate infusion was initiated at a loading dose of 20 mg/kg, followed by a maintenance dose of 5-10 mg/kg/day. Duplex ultrasound measurements of SMA BFV were recorded: peak systolic velocity (PSV), end diastolic velocity (EDV) and resistive index (RI), at 15 min before, 1-, 2- and 6-h after caffeine loading dose, and 2 h after two maintenance doses. There was a significant reduction in PSV 1-h (p = .008), a significant decrease in EDV 1- and 2-h (p = .000 and p = .005, respectively) and a significant increase in RI 1- and 2-h (p = .003 and p = .005, respectively) following caffeine loading dose, as compared to values before caffeine infusion. No significant effect of caffeine maintenance doses on SMA BFV was observed (p > .05). Blood flow in SMA is significantly reduced after caffeine citrate infusion at a loading dose of 20 mg/kg. This effect continues for at least 2 h. Meanwhile, SMA BFV seems not affected by maintenance doses.

  19. Doppler sonographic examination of uterine and placental perfusion in cows in the last month of gestation and effects of epidural anesthesia and isoxsuprine.

    PubMed

    Kim-Egloff, C; Hässig, M; Bruckmaier, R; Bleul, U

    2016-03-15

    The massive increase in size of the fetus and uterus in the last trimester is accompanied by an increasing demand for nutrients and oxygen, and it is assumed that this demand is met by increasing uterine and fetal perfusion. The goals of this study were to measure the perfusion of the uterine arteries and the placentomes in the last month of gestation and to investigate the effect of epidural anesthesia and isoxsuprine on perfusion. During the last month of gestation, eight Braunvieh cows underwent nine color Doppler sonographic examinations of the uterine arteries to determine diameter (DM), pulse rate (PR), resistance index, time-averaged maximum blood flow velocity (TAMV), and blood flow volume (BFV), and power-mode Doppler sonography was used to determine perfusion of placentomes. The PR increased (P < 0.001), and the BFV and TAMV of the ipsilateral uterine artery decreased between 4.5 and 0.5 weeks prepartum (BFV, 236.8 ± 65.80 and 208 ± 41.52 cm(3)/s, P < 0.01; TAMV, 140.0 ± 26.53 cm/s and 125.2 ± 18.46 cm/s, P < 0.05). After sonographic examination, the cows received epidural administration of local anesthetic (100-mg lidocaine) in the sacrococcygeal space or isoxsuprine (200 mg/cow, iv), and the sonographic measurements were repeated 30 minutes later. After epidural anesthesia, the TAMV and BFV of the contralateral uterine artery increased by 5.4% (P < 0.05) and 7.9% (P < 0.01). In the placentomes of the gravid uterine horn, the relative placentome perfusion and the color pixel grading (Cp) increased by 10.1% (P < 0.05) and 11.5% (P < 0.01) after epidural anesthesia. After isoxsuprine, the DM, PR, and BFV increased by 4.7%, 49.3%, and 16.9% in the ipsilateral uterine artery and by 10.8%, 48.7%, and 22.8%, respectively in the contralateral uterine artery. The TAMV of the ipsilateral uterine artery increased by 7.1% (P < 0.01), and the resistance index decreased in both uterine arteries (ipsilateral 24.2%, contralateral 14.9%, both P < 0.00001). Isoxsuprine increased the relative placentome perfusion and the Cp of the placentomes by 18.1% and 18.3% in the gravid horn and by 10.2% and 24.2% in the nongravid horn. Blood flow variables changed little in the last month of gestation. However, epidural anesthesia and isoxsuprine caused changes in uterine and placentome perfusion that suggest improvement of placental nutrient and oxygen supply to the fetus. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. An Exploratory Study of Autonomic Function Investigations in Hemophiliacs on Homoeopathy Medications Using Impedance Plethysmography

    PubMed Central

    Kundu, Tapas K.; Barde, Pradip B.; Jindal, Ghanshyam D.; Motiwala, Farooq F.

    2017-01-01

    Background. Status of autonomic homoeostasis in hemostasic disturbances due to hemophilia needs to be studied. Objectives. To compare autonomic nervous system markers measured by heart rate variability (HRV) and blood flow variability (BFV) in hemophiliacs and healthy age-matched control population using medical analyzer system. Design. Cross-sectional study. Settings. Motiwala Homoeopathy Medical College, and Hemophilia Clinics, Nashik. Subjects. Eighty subjects. Interventions. Nil. Outcome Measures. Autonomic function markers for HRV and BFV. Results. Among 80 subjects, BFV time domain measure, root mean square of successive NN (normal-to-normal) interval differences (RMSSD), was significantly higher among hemophiliacs than nonhemophiliacs. Frequency domain analysis parameter, low frequency for both HRV and BFV was significantly higher among hemophiliacs as compared with nonhemophiliacs. Conclusions. Hemophiliacs were shown to have higher autonomic activity as compared with healthy controls. Homoeopathic medicines used as an adjunct was associated with decrease in parasympathetic modulations. PMID:28719973

  1. Transcranial Doppler of the middle cerebral artery indicates regional gray matter cerebral perfusion.

    PubMed

    Pasha, Evan P; Tarumi, Takashi; Haley, Andreana P; Tanaka, Hirofumi

    2017-11-30

    We determined if transcranial color-coded Doppler derived hemodynamics are associated with MRI-based cerebral blood flow (CBF) in regions clinically important to dementia in healthy middle-aged adults. In 30 subjects (18m/12f; age  =  52  ±  1 years), blood flow velocity (BFV) and cerebrovascular conductance (CVC) were measured with transcranial color-coded Doppler (TCCD) at the middle cerebral artery (MCA) and cerebral blood flow (CBF) was assessed with arterial spin labeled perfusion MRI. BFV and CVC were associated with hippocampus (r  =  0.58 and r  =  0.61, both p  <  0.01) and occipitoparietal (r  =  0.50 and r  =  0.58, both p  <  0.01) CBF. CVC was further associated with posterior cingulate CBF (r  =  0.58 p  <  0.01). Independent of age and sex, BFV and CVC were associated with hippocampus (r  =  0.59 and r  =  0.55, both p  <  0.003) and occipitoparietal (r  =  0.50 and r  =  0.57, both p  <  0.01) CBF. CVC was independently associated with posterior cingulate CBF (r  =  0.38, p  =  0.049). TCCD-measured BFV and CVC of the MCA are indicators of cerebral perfusion to clinically valuable brain regions in healthy middle-aged adults. TCCD may not be a good indicator of blood flow to cerebral white matter.

  2. Clinical use of computational modeling for surgical planning of arteriovenous fistula for hemodialysis.

    PubMed

    Bozzetto, Michela; Rota, Stefano; Vigo, Valentina; Casucci, Francesco; Lomonte, Carlo; Morale, Walter; Senatore, Massimo; Tazza, Luigi; Lodi, Massimo; Remuzzi, Giuseppe; Remuzzi, Andrea

    2017-03-14

    Autogenous arteriovenous fistula (AVF) is the best vascular access (VA) for hemodialysis, but its creation is still a critical procedure. Physical examination, vascular mapping and doppler ultrasound (DUS) evaluation are recommended for AVF planning, but they can not provide direct indication on AVF outcome. We recently developed and validated in a clinical trial a patient-specific computational model to predict pre-operatively the blood flow volume (BFV) in AVF for different surgical configuration on the basis of demographic, clinical and DUS data. In the present investigation we tested power of prediction and usability of the computational model in routine clinical setting. We developed a web-based system (AVF.SIM) that integrates the computational model in a single procedure, including data collection and transfer, simulation management and data storage. A usability test on observational data was designed to compare predicted vs. measured BFV and evaluate the acceptance of the system in the clinical setting. Six Italian nephrology units were involved in the evaluation for a 6-month period that included all incident dialysis patients with indication for AVF surgery. Out of the 74 patients, complete data from 60 patients were included in the final dataset. Predicted brachial BFV at 40 days after surgery showed a good correlation with measured values (in average 787 ± 306 vs. 751 ± 267 mL/min, R = 0.81, p < 0.001). For distal AVFs the mean difference (±SD) between predicted vs. measured BFV was -2.0 ± 20.9%, with 50% of predicted values in the range of 86-121% of measured BFV. Feedbacks provided by clinicians indicate that AVF.SIM is easy to use and well accepted in clinical routine, with limited additional workload. Clinical use of computational modeling for AVF surgical planning can help the surgeon to select the best surgical strategy, reducing AVF early failures and complications. This approach allows individualization of VA care, with the aim to reduce the costs associated with VA dysfunction, and to improve AVF clinical outcome.

  3. Volumetric vessel reconstruction method for absolute blood flow velocity measurement in Doppler OCT images

    NASA Astrophysics Data System (ADS)

    Qi, Li; Zhu, Jiang; Hancock, Aneeka M.; Dai, Cuixia; Zhang, Xuping; Frostig, Ron D.; Chen, Zhongping

    2017-02-01

    Doppler optical coherence tomography (DOCT) is considered one of the most promising functional imaging modalities for neuro biology research and has demonstrated the ability to quantify cerebral blood flow velocity at a high accuracy. However, the measurement of total absolute blood flow velocity (BFV) of major cerebral arteries is still a difficult problem since it not only relates to the properties of the laser and the scattering particles, but also relates to the geometry of both directions of the laser beam and the flow. In this paper, focusing on the analysis of cerebral hemodynamics, we presents a method to quantify the total absolute blood flow velocity in middle cerebral artery (MCA) based on volumetric vessel reconstruction from pure DOCT images. A modified region growing segmentation method is first used to localize the MCA on successive DOCT B-scan images. Vessel skeletonization, followed by an averaging gradient angle calculation method, is then carried out to obtain Doppler angles along the entire MCA. Once the Doppler angles are determined, the absolute blood flow velocity of each position on the MCA is easily found. Given a seed point position on the MCA, our approach could achieve automatic quantification of the fully distributed absolute BFV. Based on experiments conducted using a swept-source optical coherence tomography system, our approach could achieve automatic quantification of the fully distributed absolute BFV across different vessel branches in the rodent brain.

  4. Synchronization patterns in cerebral blood flow and peripheral blood pressure under minor stroke

    NASA Astrophysics Data System (ADS)

    Chen, Zhi; Ivanov, Plamen C.; Hu, Kun; Stanley, H. Eugene; Novak, Vera

    2003-05-01

    Stroke is a leading cause of death and disability in the United States. The autoregulation of cerebral blood flow that adapts to changes in systemic blood pressure is impaired after stroke. We investigate blood flow velocities (BFV) from right and left middle cerebral arteries (MCA) and beat-to-beat blood pressure (BP) simultaneously measured from the finger, in 13 stroke and 11 healthy subjects using the mean value statistics and phase synchronization method. We find an increase in the vascular resistance and a much stronger cross-correlation with a time lag up to 20 seconds with the instantaneous phase increment of the BFV and BP signals for the subjects with stroke compared to healthy subjects.

  5. The human brain pacemaker: Synchronized infra-slow neurovascular coupling in patients undergoing non-pulsatile cardiopulmonary bypass.

    PubMed

    Zanatta, Paolo; Toffolo, Gianna Maria; Sartori, Elisa; Bet, Anna; Baldanzi, Fabrizio; Agarwal, Nivedita; Golanov, Eugene

    2013-05-15

    In non-pulsatile cardiopulmonary bypass surgery, middle cerebral artery blood flow velocity (BFV) is characterized by infra-slow oscillations of approximately 0.06Hz, which are paralleled by changes in total EEG power variability (EEG-PV), measured in 2s intervals. Since the origin of these BFV oscillations is not known, we explored their possible causative relationships with oscillations in EEG-PV at around 0.06Hz. We monitored 28 patients undergoing non-pulsatile cardiopulmonary bypass using transcranial Doppler sonography and scalp electroencephalography at two levels of anesthesia, deep (prevalence of burst suppression rhythm) and moderate (prevalence of theta rhythm). Under deep anesthesia, the EEG bursts suppression pattern was highly correlative with BFV oscillations. Hence, a detailed quantitative picture of the coupling between electrical brain activity and BFV was derived, both in deep and moderate anesthesia, via linear and non linear processing of EEG-PV and BFV signals, resorting to widely used measures of signal coupling such as frequency of oscillations, coherence, Granger causality and cross-approximate entropy. Results strongly suggest the existence of coupling between EEG-PV and BFV. In moderate anesthesia EEG-PV mean dominant frequency is similar to frequency of BFV oscillations (0.065±0.010Hz vs 0.045±0.019Hz); coherence between the two signals was significant in about 55% of subjects, and the Granger causality suggested an EEG-PV→BFV causal effect direction. The strength of the coupling increased with deepening anesthesia, as EEG-PV oscillations mean dominant frequency virtually coincided with the BFV peak frequency (0.062±0.017Hz vs 0.060±0.024Hz), and coherence became significant in a larger number (65%) of subjects. Cross-approximate entropy decreased significantly from moderate to deep anesthesia, indicating a higher level of synchrony between the two signals. Presence of a subcortical brain pacemaker that drives vascular infra-slow oscillations in the brain is proposed. These findings allow to suggest an original hypothesis explaining the mechanism underlying infra-slow neurovascular coupling. Copyright © 2013 Elsevier Inc. All rights reserved.

  6. Cerebral flow velocities during daily activities depend on blood pressure in patients with chronic ischemic infarctions.

    PubMed

    Novak, Vera; Hu, Kun; Desrochers, Laura; Novak, Peter; Caplan, Louis; Lipsitz, Lewis; Selim, Magdy

    2010-01-01

    Target blood pressure (BP) values for optimal cerebral perfusion after an ischemic stroke are still debated. We sought to examine the relationship between BP and cerebral blood flow velocities (BFVs) during daily activities. We studied 43 patients with chronic large vessel ischemic infarctions in the middle cerebral artery territory (aged 64.2+/-8.94 years; at 6.1+/-4.9 years after stroke) and 67 age-matched control subjects. BFVs in middle cerebral arteries were measured during supine baseline, sitting, standing, and tilt. A regression analysis and a dynamic phase analysis were used to quantify the BP-BFV relationship. The mean arterial pressure was similar between the groups (89+/-15 mm Hg). Baseline BFVs were lower by approximately 30% in the patients with stroke compared with the control subjects (P=0.0001). BFV declined further with postural changes and remained lower in the stroke group during sitting (P=0.003), standing (P=0.003), and tilt (P=0.002) as compared with the control group. Average BFVs on the stroke side were positively correlated with BP during baseline (R=0.54, P=0.0022, the slope 0.46 cm/s/mm Hg) and tilt (R=0.52, P=0.0028, the slope 0.40 cm/s/mm Hg). Regression analysis suggested that BFV may increase approximately 30% to 50% at mean BP >100 mm Hg. Orthostatic hypotension during the first minute of tilt or standing was independently associated with lower BFV on the stroke side (P=0.0008). Baseline BP-BFV phase shift derived from the phase analysis was smaller on the stroke side (P=0.0006). We found that BFVs are lower in patients with stroke and daily activities such as standing could induce hypoperfusion. BFVs increase with mean arterial pressure >100 mm Hg. Dependency of BFV on arterial pressure may have implications for BP management after stroke. Further prospective investigations are needed to determine the impact of these findings on functional recovery and strategies to improve perfusion pressure during daily activities after ischemic stroke.

  7. A Nonlinear Dynamic Approach Reveals a Long-Term Stroke Effect on Cerebral Blood Flow Regulation at Multiple Time Scales

    PubMed Central

    Hu, Kun; Lo, Men-Tzung; Peng, Chung-Kang; Liu, Yanhui; Novak, Vera

    2012-01-01

    Cerebral autoregulation (CA) is an important vascular control mechanism responsible for relatively stable cerebral blood flow despite changes of systemic blood pressure (BP). Impaired CA may leave brain tissue unprotected against potentially harmful effects of BP fluctuations. It is generally accepted that CA is less effective or even inactive at frequencies >∼0.1 Hz. Without any physiological foundation, this concept is based on studies that quantified the coupling between BP and cerebral blood flow velocity (BFV) using transfer function analysis. This traditional analysis assumes stationary oscillations with constant amplitude and period, and may be unreliable or even invalid for analysis of nonstationary BP and BFV signals. In this study we propose a novel computational tool for CA assessment that is based on nonlinear dynamic theory without the assumption of stationary signals. Using this method, we studied BP and BFV recordings collected from 39 patients with chronic ischemic infarctions and 40 age-matched non-stroke subjects during baseline resting conditions. The active CA function in non-stroke subjects was associated with an advanced phase in BFV oscillations compared to BP oscillations at frequencies from ∼0.02 to 0.38 Hz. The phase shift was reduced in stroke patients even at > = 6 months after stroke, and the reduction was consistent at all tested frequencies and in both stroke and non-stroke hemispheres. These results provide strong evidence that CA may be active in a much wider frequency region than previously believed and that the altered multiscale CA in different vascular territories following stroke may have important clinical implications for post-stroke recovery. Moreover, the stroke effects on multiscale cerebral blood flow regulation could not be detected by transfer function analysis, suggesting that nonlinear approaches without the assumption of stationarity are more sensitive for the assessment of the coupling of nonstationary physiological signals. PMID:22807666

  8. Complete genome sequences of two novel European clade bovine foamy viruses from Germany and Poland.

    PubMed

    Hechler, Torsten; Materniak, Magdalena; Kehl, Timo; Kuzmak, Jacek; Löchelt, Martin

    2012-10-01

    Bovine foamy virus (BFV), or bovine spumaretrovirus, is an infectious agent of cattle with no obvious disease association but high prevalence in its host. Here, we report two complete BFV sequences, BFV-Riems, isolated in 1978 in East Germany, and BFV100, isolated in 2005 in Poland. Both new BFV isolates share the overall genetic makeup of other foamy viruses (FV). Although isolated almost 25 years apart and propagated in either bovine (BFV-Riems) or nonbovine (BFV100) cells, both viruses are highly related, forming the European BFV clade. Despite clear differences, BFV-Riems and BFV100 are still very similar to BFV isolates from China and the United States, comprising the non-European BFV clade. The genomic sequences presented here confirm the concept of high sequence conservation across most of the FV genome. Analyses of cell culture-derived genomes reveal that proviral DNA may specifically lack introns in the env-bel coding region. The spacing of the splice sites in this region suggests that BFV has developed a novel mode to express a secretory but nonfunctional Env protein.

  9. Complete Genome Sequences of Two Novel European Clade Bovine Foamy Viruses from Germany and Poland

    PubMed Central

    Hechler, Torsten; Materniak, Magdalena; Kehl, Timo; Kuzmak, Jacek

    2012-01-01

    Bovine foamy virus (BFV), or bovine spumaretrovirus, is an infectious agent of cattle with no obvious disease association but high prevalence in its host. Here, we report two complete BFV sequences, BFV-Riems, isolated in 1978 in East Germany, and BFV100, isolated in 2005 in Poland. Both new BFV isolates share the overall genetic makeup of other foamy viruses (FV). Although isolated almost 25 years apart and propagated in either bovine (BFV-Riems) or nonbovine (BFV100) cells, both viruses are highly related, forming the European BFV clade. Despite clear differences, BFV-Riems and BFV100 are still very similar to BFV isolates from China and the United States, comprising the non-European BFV clade. The genomic sequences presented here confirm the concept of high sequence conservation across most of the FV genome. Analyses of cell culture-derived genomes reveal that proviral DNA may specifically lack introns in the env-bel coding region. The spacing of the splice sites in this region suggests that BFV has developed a novel mode to express a secretory but nonfunctional Env protein. PMID:22966195

  10. Characterization of Barmah Forest virus pathogenesis in a mouse model.

    PubMed

    Herrero, Lara J; Lidbury, Brett A; Bettadapura, Jayaram; Jian, Peng; Herring, Belinda L; Hey-Cunningham, William J; Sheng, Kuo-Ching; Zakhary, Andrew; Mahalingam, Suresh

    2014-10-01

    Alphaviruses including Barmah Forest virus (BFV) and Ross River virus (RRV) cause arthritis, arthralgia and myalgia in humans. The rheumatic symptoms in human BFV infection are very similar to those of RRV. Although RRV disease has been studied extensively, little is known about the pathogenesis of BFV infection. We sought to establish a mouse model for BFV to facilitate our understanding of BFV infectivity, tropism and pathogenesis, and to identify key pathological and immunological mechanisms of BFV infection that may distinguish between infections with BFV and RRV. Here, to the best of our knowledge, we report the first study assessing the virulence and replication of several BFV isolates in a mouse model. We infected newborn Swiss outbred mice with BFV and established that the BFV2193 prototype was the most virulent strain. BFV2193 infection resulted in the highest mortality among all BFV variant isolates, comparable to that of RRV. In comparison with RRV, C57BL/6 mice infected with BFV showed delayed onset, moderate disease scores and early recovery of the disease. BFV replicated poorly in muscle and did not cause the severe myositis seen in RRV-infected mice. The mRNAs for the inflammatory mediators TNF-α, IL-6, CCL2 and arginase-1 were highly upregulated in RRV- but not BFV-infected muscle. To our knowledge, this is the first report of a mouse model of BFV infection, which we have used to demonstrate differences between BFV and RRV infections and to further understand disease pathogenesis. With an increasing number of BFV cases occurring annually, a better understanding of the disease mechanisms is essential for future therapeutic development. © 2014 The Authors.

  11. Hamiltonian BFV-BRST theory of closed quantum cosmological models

    NASA Astrophysics Data System (ADS)

    Kamenshchik, A. Yu.; Lyakhovich, S. L.

    1997-02-01

    We introduce and study a new discrete basis of gravity constraints by making use of harmonic expansion for closed cosmological models. The full set of constraints is split into area-preserving spatial diffeomorphisms, forming closed subalgebra, and Virasoro-like generators. Operational Hamiltonian BFV-BRST quantization is performed in the framework of perturbative expansion in the dimensionless parameter, which is a positive power of the ratio of Planckian volume to the volume of the Universe. For the (N + 1)-dimensional generalization of stationary closed Bianchi-I cosmology the nilpotency condition for the BRST operator is examined in the first quantum approximation. It turns out that a certain relationship between the dimensionality of the space and the spectrum of matter fields emerges from the requirement of quantum consistency of the model.

  12. Hamiltonian BFV-BRST theory of closed quantum cosmological models

    NASA Astrophysics Data System (ADS)

    Kamenshchik, A. Yu.; Lyakhovich, S. L.

    1997-08-01

    We introduce and study a new discrete basis of gravity constraints by making use of the harmonic expansion for closed cosmological models. The full set of constraints is split into area-preserving spatial diffeomorphisms, forming a closed subalgebra, and Virasoro-like generators. The operatorial Hamiltonian BFV-BRST quantization is performed in the framework of a perturbative expansion in the dimensionless parameter which is a positive power of the ratio of the Planck volume to the volume of the Universe. For the (N + 1) - dimensional generalization of a stationary closed Bianchi-I cosmology the nilpotency condition for the BRST operator is examined in the first quantum approximation. It turns out that a relationship between the dimensionality of the space and the spectrum of matter fields emerges from the requirement of quantum consistency of the model.

  13. [The effects of carbogen inhalation on microvascular within lateral wall of cochlear following acute acoustic trauma].

    PubMed

    Zhao, Jing; Sun, Jianjun; Kong, Weijia

    2008-11-01

    To explore the influence of carbogen on lateral wall microvascular of cochlear after acute acoustic trauma. Forty guinea pigs were divided into 4 groups: group A (noise damage), group B (carbogen inhalation), group C (noise damage + carbogen inhalation), and the control group without any treatment. The diameter of the column of RBCs (RBC column diameter, RBCCD), blood flow velocity (BFV) and blood flow states(BFS) in microvasculature were measured and described under microscope. The microvascular in group A demonstrated a blood flow in contrary direction, granuliform flow, and granular slow flow. The erythrocytes aggregated in the microvascular of the cochlea. The RBCCD decreased 12.1% compared with the control group (P < 0.05). The blood flow in group B showed a laminar flow or laminar granular flow, and the RBCCD increased 20.7% compared with the control group. The blood condition in group C was the same as the control group-laminar granular blood flow; the blood flow with contrary direction was less than group A, and the RBCCD was 17.4% lager than that of group A. Carbogen can dilate the RBCCD and increase the BFV in stria vascular. So carbogen can alleviate the harm from noise.

  14. Intraocular pressure lowering effect of orbital decompression is related to increased venous outflow in Graves orbitopathy.

    PubMed

    Onaran, Zafer; Konuk, Onur; Oktar, Suna Özhan; Yücel, Cem; Unal, Mehmet

    2014-07-01

    To investigate the effects of combined orbital bone and fat decompression on intraocular pressure (IOP) and superior ophthalmic vein blood flow velocity (SOV-BFV), and their association with the clinical features of Graves orbitopathy (GO). During the 2002-2008 period, 72 eyes of 36 GO cases demonstrating moderate to severe orbitopathy were evaluated according to their clinical features as: cases with or without dysthyroid optic neuropathy (DON), and underwent orbital decompression. A control group comprised 40 eyes of 20 healthy subjects. In both groups, a full ophthalmic examination including IOP and Hertel measurements was performed, and SOV-BFV was analyzed with color Doppler imaging. Examinations were repeated after orbital decompression in GO patients. All the cases demonstrated clinical features of inactive disease. Among the patients 24 of 72 eyes (33.3%) showed clinical features of DON. After surgery, the mean decrease in Hertel values was 6.2 ± 1.8 mm (p = 0.001). The mean decrease in IOP was 3.0 ± 1.7 mmHg (from 17.3 ± 2.7 to 14.3 ± 2.0 mmHg) after orbital decompression where the post-operative values were comparable with the control group (12.9 ± 1.4 mmHg, p = 0.36). The mean increase in SOV-BFV achieved with decompression was 1.2 ± 0.6 cm/s (from 4.8 ± 1.7 to 6.0 ± 1.8 cm/s) and post-operative SOV-BFV values were also comparable with the control group (6.6 ± 1.3 cm/s, p = 0.26). The increase in SOV-BFV in cases with DON did not differ from cases without DON (p = 0.32), however, post-operative SOV-BFV of cases with DON was stil lower than cases without DON (p = 0.035). Combined orbital bone and fat decompression significantly reduced the IOP levels and increased the SOV-BFV in GO. This could be the confirmative finding of prediction that elevated IOP in GO is associated with increased episcleral venous pressure. The post-operative changes in IOP and SOV-BFV show differences regarding the clinical features of disease.

  15. Preparation of BFV Gag antiserum and preliminary study on cellular distribution of BFV.

    PubMed

    Wang, Jian; Guo, Hong-yan; Jia, Rui; Xu, Xuan; Tan, Juan; Geng, Yun-qi; Qiao, Wen-tao

    2010-04-01

    Viruses (e.g. Human immunodeficiency virus, Human simplex virus and Prototype foamy virus) are obligate intracellular parasites and therefore depend on the cellular machinery for cellular trafficking. Bovine foamy virus (BFV) is a member of the Spumaretrovirinae subfamily of Retroviruses, however, details of its cellular trafficking remain unknown. In this study, we cloned the BFV gag gene into prokaryotic expression vector pET28a and purified the denaturalized Gag protein. The protein was used to immunize BALB/c mouse to produce antiserum, which could specifically recognize the BFV Gag protein in BFV-infected cells through western blot assay. Additionally, these results demonstrated that both the optimal and suboptimal cleavage of Gag protein occur in BFV-infected cells. Subsequently, the Gag antiserum was used to investigate subcellular localization of BFV. In immunofluorescence microscopy assays, colocalization microtubules (MTs) and assembling viral particles were clearly observed, which implied that BFV may transport along cellular MTs in host cells. Furthermore, MTs-depolymerizing assay indicated MTs were required for the efficient replication of BFV. In conclusion, our study suggests that BFV has evolved the mechanism to hijack the cellular cytoskeleton for its replication.

  16. Effects of exercise program on physiological functions in postmenopausal women with metabolic syndrome.

    PubMed

    Heli, Valkeinen; Ihab, Hajjar; Kun, Hu; Brad, Manor; Jessica, Wisocky; Vera, Novak

    2013-12-01

    The purpose of this study was to examine effects of mixed interval aerobic and strength training (MAST) program on physiological functions in older women with metabolic syndrome. 12 subjects were randomly assigned to the exercise group (16-week MAST program) or the control group. Outcomes included oxygen uptake (VO 2max ), cerebral blood flow velocity (BFV) and cognitive functions. The exercise group demonstrated increased VO 2max and certain improvements in cognitive functions. No changes were observed in BFV for both groups. These results can be used as a preliminary data for planning larger studies.

  17. Wetlands, climate zones and Barmah Forest virus disease in Queensland, Australia.

    PubMed

    Naish, Suchithra; Mengersen, Kerrie; Hu, Wenbiao; Tong, Shilu

    2012-12-01

    Barmah Forest virus (BFV) disease is the second most common mosquito-borne disease in Australia, but the linkages of the wetlands and climate zones with BFV transmission remain unclear. We aimed to examine the relationship between the wetlands, climate zones and BFV risk in Queensland, Australia. Data on the wetlands, climate zones, population and BFV cases for the period 1992 to 2008 were obtained from relevant government agencies. BFV risk was grouped as low-, medium- and high-level based on BFV incidence percentiles. The buffer zones around each BFV case were made using 1, 5, 10, 15, 20, 25 and 50km distances. We performed a discriminant analysis to determine the differences between wetland classes and BFV risk within each climate zone. The discriminant analyses show that saline 1, riverine and saline tidal influence were the most significant contributors to BFV risk in all climate and buffer zones, while lacustrine, palustrine, estuarine and saline 2 and saline 3 wetlands were less important. These models had classification accuracies of 76%, 98% and 100% for BFV risk in subtropical, tropical and temperate climate zones, respectively. This study demonstrates that BFV risk varies with wetland class and climate zone. The discriminant analysis is a useful tool to quantify the links between wetlands, climate zones and BFV risk. Copyright © 2012 Royal Society of Tropical Medicine and Hygiene. Published by Elsevier Ltd. All rights reserved.

  18. Spatio-temporal patterns of Barmah Forest virus disease in Queensland, Australia.

    PubMed

    Naish, Suchithra; Hu, Wenbiao; Mengersen, Kerrie; Tong, Shilu

    2011-01-01

    Barmah Forest virus (BFV) disease is a common and wide-spread mosquito-borne disease in Australia. This study investigated the spatio-temporal patterns of BFV disease in Queensland, Australia using geographical information system (GIS) tools and geostatistical analysis. We calculated the incidence rates and standardised incidence rates of BFV disease. Moran's I statistic was used to assess the spatial autocorrelation of BFV incidences. Spatial dynamics of BFV disease was examined using semi-variogram analysis. Interpolation techniques were applied to visualise and display the spatial distribution of BFV disease in statistical local areas (SLAs) throughout Queensland. Mapping of BFV disease by SLAs reveals the presence of substantial spatio-temporal variation over time. Statistically significant differences in BFV incidence rates were identified among age groups (χ(2) = 7587, df = 7327,p<0.01). There was a significant positive spatial autocorrelation of BFV incidence for all four periods, with the Moran's I statistic ranging from 0.1506 to 0.2901 (p<0.01). Semi-variogram analysis and smoothed maps created from interpolation techniques indicate that the pattern of spatial autocorrelation was not homogeneous across the state. This is the first study to examine spatial and temporal variation in the incidence rates of BFV disease across Queensland using GIS and geostatistics. The BFV transmission varied with age and gender, which may be due to exposure rates or behavioural risk factors. There are differences in the spatio-temporal patterns of BFV disease which may be related to local socio-ecological and environmental factors. These research findings may have implications in the BFV disease control and prevention programs in Queensland.

  19. Detection and analysis of bovine foamy virus infection by an indicator cell line.

    PubMed

    Ma, Zhe; Qiao, Wen-tao; Xuan, Cheng-hao; Xie, Jin-hui; Chen, Qi-min; Geng, Yun-qi

    2007-07-01

    To determine the infectivity and replication strategy of bovine foamy virus (BFV) in different cultured cells using the BFV indicator cell line (BICL) system. BFV infection was induced by the co-culture method or the transient transfection of the infectious BFV plasmid [pCMV (cytomegalovirus) - BFV] clone. The infectivity of BFV was monitored by the percentage of green fluorescent protein-positive cells in the BICL. The effect of reverse transcriptase inhibitor zidovudine (AZT) on BFV replication was also evaluated in the BICL. The titer of BFV in fetal bovine lung cells was 4-5-folds more than that in either 293T or HeLa (Cells from Henrietta lacks) cells using the co-culture method, and in the meantime was significantly higher than that produced by the infectious clone pCMV-BFV in the same cells. AZT had only a minor effect on viral titers when added to cells prior to the virus infection. In contrast, viral titers reduced sharply to the level of the negative control when the virus was produced from cells in the presence of AZT. BICL can be used for the titration of the BFV viral infection in non-cytopathic condition. In addition, we provide important evidence to show that reverse transcription is essential for BFV replication at a late step of viral infection.

  20. The Hemodynamic Changes in Patients with Cerebral Arteriovenous Malformations before and after Interventional Embolization Therapy with Glubran 2 Acrylic Glue.

    PubMed

    Chen, Qi-Yu; Zhu, Xiao-Rui; Zhang, Yu

    2017-01-01

    The study explored hemodynamic changes in patients with cerebral arteriovenous malformations (CAVM) before and -after interventional embolization therapy with Glubran 2 acrylic glue and analyzed the related factors. CAVM patients received endovascular embolization therapy with Glubran 2. Patients' systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure (MAP), blood flow velocity (BFV), and pulsatility index (PI) were measured. The location of malformed vessels, Spetzler-Martin (SM) grade, CAVM size, and type of feeding artery and venous drainage were analyzed. CAVM patients showed increased DBP, SBP, MAP, and PI and decreased average BFV compared to before therapy. CAVM patients with big CAVM size, SM grade IV/V, deep location malformed vessels, deep, and mixed venous drainage, and cortical branch and mixed artery blood-supply exhibited lower DBP, SBP, MAP, and PI but higher average BFV. Hypertensive CAVM patients showed lower DBP, SBP, MAP, average BFV, and PI before or after embolization. Hypertension, SM grade, CAVM size, malformed vessels location, venous drainage, and artery blood-supply were correlated to the hemodynamic changes of CAVM patients. Embolization with Glubran 2 acrylic glue could enhance hemodynamics in CAVM patients, and the hemodynamic changes were in correlation with the SM grade, CAVM size, and malformed vessels location. © 2017 S. Karger AG, Basel.

  1. Unmasking a sustained negative effect of SGLT2 inhibition on body fluid volume in the rat.

    PubMed

    Masuda, Takahiro; Watanabe, Yuko; Fukuda, Keiko; Watanabe, Minami; Onishi, Akira; Ohara, Ken; Imai, Toshimi; Koepsell, Hermann; Muto, Shigeaki; Vallon, Volker; Nagata, Daisuke

    2018-05-23

    The chronic intrinsic diuretic and natriuretic tone of sodium-glucose cotransporter 2 (SGLT2) inhibitors is incompletely understood, because their effect on body fluid volume (BFV) has not been fully evaluated and because they often increase food and fluid intake at the same time. Here we first compared the effect of the SGLT2 inhibitor ipragliflozin (Ipra, 0.01% in diet for 8 weeks) and vehicle (Veh) in Spontaneously Diabetic Torii rat, a non-obese type 2 diabetic model, and non-diabetic Sprague-Dawley rats. In non-diabetic rats, Ipra increased urinary excretion of Na+ (UNaV) and fluid (UV) associated with increased food and fluid intake. Diabetes increased these 4 parameters, but Ipra had no further effect; probably due to its antihyperglycemic effect, such that glucosuria and as a consequence food and fluid intake were unchanged. Fluid balance and BFV, determined by bioimpedance spectroscopy, were similar among the 4 groups. To study the impact of food and fluid intake, non-diabetic rats were treated for 7 days with Veh, Ipra or Ipra+pair-feeding+pair-drinking (Pair-Ipra). Pair-Ipra maintained a small increase in UV and UNaV versus Veh despite similar food and fluid intake. Pair-Ipra induced a negative fluid balance and decreased BFV, while Ipra or Veh had no significant effect compared with basal values. In conclusion, SGLT2 inhibition induces a sustained diuretic and natriuretic tone. Homeostatic mechanisms are activated to stabilize body fluid volume, including compensatory increases in fluid and food intake.

  2. Spatio-Temporal Patterns of Barmah Forest Virus Disease in Queensland, Australia

    PubMed Central

    Naish, Suchithra; Hu, Wenbiao; Mengersen, Kerrie; Tong, Shilu

    2011-01-01

    Background Barmah Forest virus (BFV) disease is a common and wide-spread mosquito-borne disease in Australia. This study investigated the spatio-temporal patterns of BFV disease in Queensland, Australia using geographical information system (GIS) tools and geostatistical analysis. Methods/Principal Findings We calculated the incidence rates and standardised incidence rates of BFV disease. Moran's I statistic was used to assess the spatial autocorrelation of BFV incidences. Spatial dynamics of BFV disease was examined using semi-variogram analysis. Interpolation techniques were applied to visualise and display the spatial distribution of BFV disease in statistical local areas (SLAs) throughout Queensland. Mapping of BFV disease by SLAs reveals the presence of substantial spatio-temporal variation over time. Statistically significant differences in BFV incidence rates were identified among age groups (χ2 = 7587, df = 7327,p<0.01). There was a significant positive spatial autocorrelation of BFV incidence for all four periods, with the Moran's I statistic ranging from 0.1506 to 0.2901 (p<0.01). Semi-variogram analysis and smoothed maps created from interpolation techniques indicate that the pattern of spatial autocorrelation was not homogeneous across the state. Conclusions/Significance This is the first study to examine spatial and temporal variation in the incidence rates of BFV disease across Queensland using GIS and geostatistics. The BFV transmission varied with age and gender, which may be due to exposure rates or behavioural risk factors. There are differences in the spatio-temporal patterns of BFV disease which may be related to local socio-ecological and environmental factors. These research findings may have implications in the BFV disease control and prevention programs in Queensland. PMID:22022430

  3. Investigation into High Barmah Forest Virus Disease Case Numbers Reported in the Northern Territory, Australia in 2012-2013.

    PubMed

    Kurucz, Nina; Markey, Peter; Draper, Anthony; Melville, Lorna; Weir, Richard; Davis, Steven; Warchot, Allan; Boyd, Rowena; Stokeld, Danielle

    2016-02-01

    Between October 2012 and October 2013, unprecedented high numbers of Barmah Forest virus (BFV) disease cases were reported in the Northern Territory (NT). An investigation was launched by the NT Department of Health in cooperation with the Department of Primary Industry and Fisheries and the Department of Land Resource Management to investigate possible causes for this phenomenon. The investigation included virus isolations from mosquitoes collected in Darwin urban areas, BFV antibody testing in peri-urban small mammals and a human BFV disease case series investigation of recent cases. No BFV was isolated from the 4641 mosquitoes tested, none of the mammals tested positive for BFV antibodies, and the high BFV disease case numbers did not correlate with the relatively low mosquito vector numbers trapped in 2012-2013. It was estimated that up to 89% of the 79 human cases investigated did not have an acute arboviral illness and therefore had tested falsely positive. An Alere PanBio BFV immunoglobulin M enzyme-linked immunosorbent assay test kit is generally used to test for BFV, with the BFV disease case definition based on immunoglobulin M positives only. Other jurisdictions in Australia also reported high numbers of BFV disease cases, with the majority of the cases suspected to be false positives. Therefore, current testing methods need to be revised to reflect the true numbers of BFV disease cases occurring in Australia and to provide correct diagnoses for patients.

  4. Similar Patterns of Infection with Bovine Foamy Virus in Experimentally Inoculated Calves and Sheep

    PubMed Central

    Hechler, Torsten; Löchelt, Martin; Kuźmak, Jacek

    2013-01-01

    Foamy viruses (FVs) are the least known retroviruses commonly found in primates, cats, horses, and cattle. Although FVs are considered apathogenic, simian and feline FVs have been shown to be associated with some transient health abnormalities in animal models. Currently, data regarding the course of infection with bovine FV (BFV) are not available. In this study, we conducted experimental infections of natural (cattle) and heterologous (sheep) hosts with the BFV100 isolate and monitored infection patterns in both hosts during the early phase postinoculation as well as after long-term infection. Four calves and six sheep inoculated with BFV100 showed no signs of pathology but developed persistent infection, as confirmed by virus rescue, consistent detection of BFV-specific antibodies, and presence of viral DNA. In both hosts, antibodies against BFV Gag and Bet appeared early after infection and persisted at high and stable levels while seroreactivity toward Env was consistently detectable only in BFV-infected sheep. Interestingly, the BFV proviral DNA load was highest in lung, spleen, and liver and moderate in leukocytes, while salivary glands contained either low or undetectable DNA loads in calves or sheep, respectively. Additionally, comparison of partial BFV sequences from inoculum and infected animals demonstrated very limited changes after long-term infection in the heterologous host, clearly less than those found in BFV field isolates. The persistence of BFV infection in both hosts suggests full replication competence of the BFV100 isolate with no requirement of genetic adaptation for productive replication in the authentic and even in a heterologous host. PMID:23325680

  5. Similar patterns of infection with bovine foamy virus in experimentally inoculated calves and sheep.

    PubMed

    Materniak, Magdalena; Hechler, Torsten; Löchelt, Martin; Kuzmak, Jacek

    2013-03-01

    Foamy viruses (FVs) are the least known retroviruses commonly found in primates, cats, horses, and cattle. Although FVs are considered apathogenic, simian and feline FVs have been shown to be associated with some transient health abnormalities in animal models. Currently, data regarding the course of infection with bovine FV (BFV) are not available. In this study, we conducted experimental infections of natural (cattle) and heterologous (sheep) hosts with the BFV(100) isolate and monitored infection patterns in both hosts during the early phase postinoculation as well as after long-term infection. Four calves and six sheep inoculated with BFV(100) showed no signs of pathology but developed persistent infection, as confirmed by virus rescue, consistent detection of BFV-specific antibodies, and presence of viral DNA. In both hosts, antibodies against BFV Gag and Bet appeared early after infection and persisted at high and stable levels while seroreactivity toward Env was consistently detectable only in BFV-infected sheep. Interestingly, the BFV proviral DNA load was highest in lung, spleen, and liver and moderate in leukocytes, while salivary glands contained either low or undetectable DNA loads in calves or sheep, respectively. Additionally, comparison of partial BFV sequences from inoculum and infected animals demonstrated very limited changes after long-term infection in the heterologous host, clearly less than those found in BFV field isolates. The persistence of BFV infection in both hosts suggests full replication competence of the BFV(100) isolate with no requirement of genetic adaptation for productive replication in the authentic and even in a heterologous host.

  6. Effects of a protracted induction of parturition on the incidence of retained placenta and assessment of uterine artery blood flow as a measure of placental maturation in cattle.

    PubMed

    Hartmann, D; Honnens, A; Piechotta, M; Lüttgenau, J; Niemann, H; Rath, D; Bollwein, H

    2013-08-01

    The objectives of the present study were to compare the effects of a protracted and a conventional induction of parturition on the incidence of retained placenta, and to evaluate the suitability of transrectal Doppler sonography of the uterine arteries as a noninvasive method for the assessment of placental maturation. Protracted induction of labor (PIP) was precipitated in 13 cows by the administration of 1.3 mg dexamethasone im twice daily between Days 268 and 273 of gestation, and 40 mg dexamethasone im on Day 274 of gestation. For conventional induction of labor (SIP), 10 cows received 40 mg dexamethasone on Day 274 of gestation. A third group was not treated and served as control (SPON; N = 11). Blood flow volume (BFV) and resistance index in the uterine arteries were measured with Doppler sonography once a day from Day 268 of gestation until labor. After each ultrasonographic examination, blood samples for determination of steroid hormones were taken. Incidence of retained placenta was lower (P < 0.05) in group SPON (9%) compared with groups PIP (54%) and SIP (70%). In the last 7 days before parturition uterine BFV and resistance index did not change (P > 0.05) and did not differ between groups SPON, PIP, and SIP (P > 0.05). Resistance index was higher (P < 0.001) in cows with retained placenta compared with cows with released placenta, and BFV did not differ (P > 0.05) between them. Total estrogen concentrations increased by 283% (P < 0.001) in group PIP and by 60% (P < 0.05) in group SPON between Days -7 and -1 before parturition. They stayed constant (P > 0.05) until Day -2 in group SIP, but increased (P < 0.05) after the high dosage of dexamethasone within 1 day by 140%. Total estrogen levels were higher (P < 0.05) in cows with released placenta than in cows with retained placenta. In conclusion, a protracted compared with a short induction of labor results in higher estrogen levels before term, but does not affect incidence of placental retention. Neither alterations in placental maturation nor changes in steroid hormones influenced uterine blood supply. Therefore, Doppler sonography of uterine arteries is unsuitable to investigate the process of placental maturation induced by glucocorticoids in cows. Nevertheless, disturbances in the placental maturation process in cows with retained fetal membranes after parturition can be detected before parturition by a higher uterine blood flow resistance in the uterine arteries. Copyright © 2013 Elsevier Inc. All rights reserved.

  7. Establishment of an indicator cell line to quantify bovine foamy virus infection.

    PubMed

    Ma, Zhe; Hao, Peng; Yao, Xue; Liu, Chang; Tan, Juan; Liu, Li; Yang, Rongge; Geng, Yunqi; Chen, Qimin; Qiao, Wentao

    2008-08-01

    A cell line derived from baby hamster kidney (BHK-21) cells was transfected with the enhanced green fluorescent protein gene driven by the bovine foamy virus (BFV) long terminal repeat (LTR) to establish a BFV indicator cell line (BICL). Among 48 clones, one clone was chosen for its little constitutive enhanced green fluorescent protein (EGFP) expression and high level of EGFP expression after activation by BFV infection. By detecting the EGFP expression of the BFV indicator cell line, the titers of BFV were quantified by the end point method. As a result, the titer determined by the EGFP based assay 5-6 days post infection (d.p.i.) was 100 fold higher than traditional assays measuring cytopathic effects 8-9 d.p.i.. Moreover, the EGFP based assay was also used to determine the titer of those cells infected by BFV without inducing cytopathic effects. Using this simple and rapid assay, we examined the in vitro host range of BFV. It was found that BFV can productively infect various cell lines derived from bovine, human, rat and monkey. (c) 2008 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Serological detection systems for identification of cows shedding bovine foamy virus via milk.

    PubMed

    Romen, Fabian; Backes, Perdita; Materniak, Magda; Sting, Reinhard; Vahlenkamp, Thomas W; Riebe, Roland; Pawlita, Michael; Kuzmak, Jacek; Löchelt, Martin

    2007-07-20

    The biology of foamy viruses, their mode of transmission and disease potential in their natural host and after interspecies transmission are largely unknown. To gain insights into the prevalence of bovine foamy virus (BFV) and its zoonotic potential, enzyme-linked immunosorbent assays (ELISAs) were established to determine antibody responses against Gag, Env, and the non-structural protein Bet in bovine serum and milk. In Polish cattle, strong Gag reactivity was most frequent (41.5%) and strongly associated with Bet antibodies, Env antibodies were less frequent. German cattle showed a low overall BFV antibody prevalence of 6.8%. Besides clearly BFV-positive animals, a substantial number of weakly reacting cattle were identified. BFV-specific antibodies were also detectable in milk. BFV was isolated from PBLs and milk cells of BFV-positive cattle but not from antibody-negative or weakly reacting animals. The implications of these findings for the potential interspecies transmission of BFV to humans will be discussed.

  9. Age-Related Alterations in the Retinal Microvasculature, Microcirculation, and Microstructure.

    PubMed

    Wei, Yantao; Jiang, Hong; Shi, Yingying; Qu, Dongyi; Gregori, Giovanni; Zheng, Fang; Rundek, Tatjana; Wang, Jianhua

    2017-07-01

    To characterize age-related alterations in the retinal microcirculation, microvascular network, and microstructure in healthy subjects. Seventy-four healthy subjects aged from 18 to 82 years were recruited and divided into four age groups (G1 with age <35 years, G2 with age 35 ∼ 49 years, G3 with age 50 ∼ 64 years, and G4 with age ≥65 years). Custom ultra-high resolution optical coherence tomography (UHR-OCT) was used to acquire six intraretinal layers of the macula. OCT angiography (OCTA) was used to image the retinal microvascular network. The retinal blood flow velocity (BFV) was measured using a Retinal Function Imager (RFI). Compared to G1, G2 had significant thinning of the retinal nerve fiber layer (RNFL) (P < 0.05), while G3 had thinning of the RNFL and ganglion cell and inner plexiform layer (GCIPL) (P < 0.05), in addition to thickening of the outer plexiform layer (OPL) and photoreceptor layer (PR) (P < 0.05). G4 had loss in retinal vessel density, thinning in RNFL and GCIPL, and decrease in venular BFV, in addition to thickening of the OPL and PR (P < 0.05). Age was negatively related to retinal vessel densities, the inner retinal layers, and venular BFV (P < 0.05). By contrast, age was positively related to OPL and PR (P < 0.05). During aging, decreases in retinal vessel density, inner retinal layer thickness, and venular BFV were evident and impacted each other as observed by simultaneous changes in multiple retinal components.

  10. Assessment of intracranial venous blood flow after subarachnoid hemorrhage: a new approach to diagnose vasospasm with transcranial color-coded duplex sonography.

    PubMed

    Connolly, Florian; Schreiber, Stephan J; Leithner, Christoph; Bohner, Georg; Vajkoczy, Peter; Valdueza, José M

    2017-12-15

    OBJECTIVE Transcranial color-coded duplex sonography (TCCS) is a reliable tool that is used to assess vasospasm in the M 1 segment of the middle cerebral artery (MCA) after subarachnoid hemorrhage (SAH). A distinct increase in blood flow velocity (BFV) is the principal criterion for vasospasm. The MCA/internal carotid artery (ICA) index (Lindegaard Index) is also widely used to distinguish between vasospasm and cerebral hyperperfusion. However, extracranial ultrasonography assessment of the neck vessels might be difficult in an intensive care unit. Therefore, the authors evaluated whether the relationship of intracranial arterial to venous BFV might indicate vasospasm with similar or even better accuracy. METHODS Patients who presented between 2008 and 2015 with aneurysmal SAH were prospectively enrolled in the study. Digital subtraction angiography (DSA) and TCCS were performed within 24 hours of each other to assess vasospasm 8-10 days after SAH. The following different TCCS parameters were analyzed to assess vasospasm in the MCA and were compared with the gold-standard DSA parameters: 1) mean time-averaged maximum BFV (V mean ) of the MCA, 2) peak systolic velocity (PSV) of the MCA, 3) the Lindegaard Index using V mean as well as PSV, and 4) a new arteriovenous index (AVI) between the MCA and the basal vein of Rosenthal using V mean and PSV. The best cutoff values for these parameters to distinguish vasospasm from normal perfusion or hyperperfusion were calculated using receiver operating characteristic curve analysis. Sensitivity, specificity, positive predictive value, and negative predictive value as well as the overall accuracy for each cutoff value were analyzed. RESULTS A total of 102 patients (mean age 52 ± 12 years) were evaluated. Bilateral MCA assessment by TCCS was successful in all patients. In 6 cases (3%), the BFV of the basal vein of Rosenthal could not be analyzed. The AVI could not be calculated in 50 of 204 cases (25%) because the insonation quality was very low in one of the ICAs. An AVI > 10 for V mean and an AVI > 12 for systolic velocity provided the highest accuracies of 87% and 86%, respectively. Regarding the Lindegaard Index, the accuracy was highest using a threshold of > 3 for the mean BFV (84%) as well as systolic BFV (80%). BFVs in the MCA of ≥ 120 cm/sec (V mean ) and ≥ 200 cm/sec (PSV) predicted vasospasm with accuracies of 84% and 83%, respectively. A combined analysis of the MCA BFV and the AVI led to a slight increase in specificity (V mean , 94%; PSV, 93%) and positive predictive value (V mean , 88%; PSV 86%) without further improvement in accuracy (V mean , 88%; PSV, 84%). CONCLUSIONS The intracranial AVI is a reliable parameter that can be used to assess vasospasm after SAH. Its reliability for differentiating vasospasm and hyperperfusion is slightly higher than that for the established Lindegaard Index, and this method has the additional advantage of a remarkably lower failure rate.

  11. BFV-Complex and Higher Homotopy Structures

    NASA Astrophysics Data System (ADS)

    Schätz, Florian

    2009-03-01

    We present a connection between the BFV-complex (abbreviation for Batalin-Fradkin-Vilkovisky complex) and the strong homotopy Lie algebroid associated to a coisotropic submanifold of a Poisson manifold. We prove that the latter structure can be derived from the BFV-complex by means of homotopy transfer along contractions. Consequently the BFV-complex and the strong homotopy Lie algebroid structure are L ∞ quasi-isomorphic and control the same formal deformation problem. However there is a gap between the non-formal information encoded in the BFV-complex and in the strong homotopy Lie algebroid respectively. We prove that there is a one-to-one correspondence between coisotropic submanifolds given by graphs of sections and equivalence classes of normalized Maurer-Cartan elemens of the BFV-complex. This does not hold if one uses the strong homotopy Lie algebroid instead.

  12. Socio-environmental predictors of Barmah forest virus transmission in coastal areas, Queensland, Australia.

    PubMed

    Naish, Suchithra; Hu, Wenbiao; Nicholls, Neville; Mackenzie, John S; Dale, Pat; McMichael, Anthony J; Tong, Shilu

    2009-02-01

    To assess the socio-environmental predictors of Barmah forest virus (BFV) transmission in coastal areas, Queensland, Australia. Data on BFV notified cases, climate, tidal levels and socioeconomic index for area (SEIFA) in six coastal cities, Queensland, for the period 1992-2001 were obtained from the relevant government agencies. Negative binomial regression models were used to assess the socio-environmental predictors of BFV transmission. The results show that maximum and minimum temperature, rainfall, relative humidity, high and low tide were statistically significantly associated with BFV incidence at lags 0-2 months. The fitted negative binomial regression models indicate a significant independent association of each of maximum temperature (beta = 0.139, P = 0.000), high tide (beta = 0.005, P = 0.000) and SEIFA index (beta = -0.010, P = 0.000) with BFV transmission after adjustment for confounding variables. The transmission of BFV disease in Queensland coastal areas seemed to be determined by a combination of local social and environmental factors. The model developed in this study may have applications in the control and prevention of BFV disease in these areas.

  13. Important role of N108 residue in binding of bovine foamy virus transactivator Tas to viral promoters.

    PubMed

    Bing, Tiejun; Zhang, Suzhen; Liu, Xiaojuan; Liang, Zhibin; Shao, Peng; Zhang, Song; Qiao, Wentao; Tan, Juan

    2016-06-30

    Bovine foamy virus (BFV) encodes the transactivator BTas, which enhances viral gene transcription by binding to the long terminal repeat promoter and the internal promoter. In this study, we investigated the different replication capacities of two similar BFV full-length DNA clones, pBS-BFV-Y and pBS-BFV-B. Here, functional analysis of several chimeric clones revealed a major role for the C-terminal region of the viral genome in causing this difference. Furthermore, BTas-B, which is located in this C-terminal region, exhibited a 20-fold higher transactivation activity than BTas-Y. Sequence alignment showed that these two sequences differ only at amino acid 108, with BTas-B containing N108 and BTas-Y containing D108 at this position. Results of mutagenesis studies demonstrated that residue N108 is important for BTas binding to viral promoters. In addition, the N108D mutation in pBS-BFV-B reduced the viral replication capacity by about 1.5-fold. Our results suggest that residue N108 is important for BTas binding to BFV promoters and has a major role in BFV replication. These findings not only advances our understanding of the transactivation mechanism of BTas, but they also highlight the importance of certain sequence polymorphisms in modulating the replication capacity of isolated BFV clones.

  14. Weapon and Sighting System Compatibility Assessment for Prototype Maxillofacial Protection Devices

    DTIC Science & Technology

    2013-03-01

    No Maxillofacial Protection, No Visor (figure 38) ...........................22 7.2 Sighting System Compatibility – Bradley Fighting Vehicle ( BFV ...23 Figure 39. FASTBAC, bracket only ( BFV ...23 Figure 40. FASTBAC bracket and maxillofacial protection ( BFV ). ............................................24 Figure 41. FIREBALL

  15. Identification of novel, highly expressed retroviral microRNAs in cells infected by bovine foamy virus.

    PubMed

    Whisnant, Adam W; Kehl, Timo; Bao, Qiuying; Materniak, Magdalena; Kuzmak, Jacek; Löchelt, Martin; Cullen, Bryan R

    2014-05-01

    While numerous viral microRNAs (miRNAs) expressed by DNA viruses, especially herpesvirus family members, have been reported, there have been very few reports of miRNAs derived from RNA viruses. Here we describe three miRNAs expressed by bovine foamy virus (BFV), a member of the spumavirus subfamily of retroviruses, in both BFV-infected cultured cells and BFV-infected cattle. All three viral miRNAs are initially expressed in the form of an ∼ 122-nucleotide (nt) pri-miRNA, encoded within the BFV long terminal repeat U3 region, that is subsequently cleaved to generate two pre-miRNAs that are then processed to yield three distinct, biologically active miRNAs. The BFV pri-miRNA is transcribed by RNA polymerase III, and the three resultant mature miRNAs were found to contribute a remarkable ∼ 70% of all miRNAs expressed in BFV-infected cells. These data document the second example of a retrovirus that is able to express viral miRNAs by using embedded proviral RNA polymerase III promoters. Foamy viruses are a ubiquitous family of nonpathogenic retroviruses that have potential as gene therapy vectors in humans. Here we demonstrate that bovine foamy virus (BFV) expresses high levels of three viral microRNAs (miRNAs) in BFV-infected cells in culture and also in infected cattle. The BFV miRNAs are unusual in that they are initially transcribed by RNA polymerase III as a single, ∼ 122-nt pri-miRNA that is subsequently processed to release three fully functional miRNAs. The observation that BFV, a foamy virus, is able to express viral miRNAs in infected cells adds to emerging evidence that miRNA expression is a common, albeit clearly not universal, property of retroviruses and suggests that these miRNAs may exert a significant effect on viral replication in vivo.

  16. Identification of Novel, Highly Expressed Retroviral MicroRNAs in Cells Infected by Bovine Foamy Virus

    PubMed Central

    Whisnant, Adam W.; Kehl, Timo; Bao, Qiuying; Materniak, Magdalena; Kuzmak, Jacek; Löchelt, Martin

    2014-01-01

    ABSTRACT While numerous viral microRNAs (miRNAs) expressed by DNA viruses, especially herpesvirus family members, have been reported, there have been very few reports of miRNAs derived from RNA viruses. Here we describe three miRNAs expressed by bovine foamy virus (BFV), a member of the spumavirus subfamily of retroviruses, in both BFV-infected cultured cells and BFV-infected cattle. All three viral miRNAs are initially expressed in the form of an ∼122-nucleotide (nt) pri-miRNA, encoded within the BFV long terminal repeat U3 region, that is subsequently cleaved to generate two pre-miRNAs that are then processed to yield three distinct, biologically active miRNAs. The BFV pri-miRNA is transcribed by RNA polymerase III, and the three resultant mature miRNAs were found to contribute a remarkable ∼70% of all miRNAs expressed in BFV-infected cells. These data document the second example of a retrovirus that is able to express viral miRNAs by using embedded proviral RNA polymerase III promoters. IMPORTANCE Foamy viruses are a ubiquitous family of nonpathogenic retroviruses that have potential as gene therapy vectors in humans. Here we demonstrate that bovine foamy virus (BFV) expresses high levels of three viral microRNAs (miRNAs) in BFV-infected cells in culture and also in infected cattle. The BFV miRNAs are unusual in that they are initially transcribed by RNA polymerase III as a single, ∼122-nt pri-miRNA that is subsequently processed to release three fully functional miRNAs. The observation that BFV, a foamy virus, is able to express viral miRNAs in infected cells adds to emerging evidence that miRNA expression is a common, albeit clearly not universal, property of retroviruses and suggests that these miRNAs may exert a significant effect on viral replication in vivo. PMID:24522910

  17. Age-Related Alterations in the Retinal Microvasculature, Microcirculation, and Microstructure

    PubMed Central

    Wei, Yantao; Jiang, Hong; Shi, Yingying; Qu, Dongyi; Gregori, Giovanni; Zheng, Fang; Rundek, Tatjana; Wang, Jianhua

    2017-01-01

    Purpose To characterize age-related alterations in the retinal microcirculation, microvascular network, and microstructure in healthy subjects. Methods Seventy-four healthy subjects aged from 18 to 82 years were recruited and divided into four age groups (G1 with age <35 years, G2 with age 35 ∼ 49 years, G3 with age 50 ∼ 64 years, and G4 with age ≥65 years). Custom ultra-high resolution optical coherence tomography (UHR-OCT) was used to acquire six intraretinal layers of the macula. OCT angiography (OCTA) was used to image the retinal microvascular network. The retinal blood flow velocity (BFV) was measured using a Retinal Function Imager (RFI). Results Compared to G1, G2 had significant thinning of the retinal nerve fiber layer (RNFL) (P < 0.05), while G3 had thinning of the RNFL and ganglion cell and inner plexiform layer (GCIPL) (P < 0.05), in addition to thickening of the outer plexiform layer (OPL) and photoreceptor layer (PR) (P < 0.05). G4 had loss in retinal vessel density, thinning in RNFL and GCIPL, and decrease in venular BFV, in addition to thickening of the OPL and PR (P < 0.05). Age was negatively related to retinal vessel densities, the inner retinal layers, and venular BFV (P < 0.05). By contrast, age was positively related to OPL and PR (P < 0.05). Conclusions During aging, decreases in retinal vessel density, inner retinal layer thickness, and venular BFV were evident and impacted each other as observed by simultaneous changes in multiple retinal components. PMID:28744554

  18. A new indicator cell line established to monitor bovine foamy virus infection.

    PubMed

    Guo, Hong-Yan; Liang, Zhi-Bin; Li, Yue; Tan, Juan; Chen, Qi-Min; Qiao, Wen-Tao

    2011-10-01

    In order to improve the accuracy for quantitating the bovine foamy virus (BFV) in vitro, we developed a baby hamster kidney cell (BHK)-21-derived indicator cell line containing a plasmid that encodes the firefly luciferase driven by the BFV long terminal repeat promoter (LTR, from -7 to 1012). The BFV titer could be determined by detecting the luciferase expression since the viral trans-activator BTas protein activates the promoter activity of the LTR. One clone, designated BFVL, was selected from ten neomycin-resistant clones. BFVL showed a specific and inducible dose- and time-dependent luciferase activity in response to BFV infection. Although the changes in luciferase activity of BFVL peaked at 84 h post infection, it was possible to differentiate infected and uninfected cells at 48 h post infection. A linear relationship was established between the multiplicity of infection (MOI) of BFV and the activated ratio of luciferase expression in BFVL. Moreover, the sensitivity of the BFVL-based assay for detecting infectious BFV was 10,000 times higher than the conventional CPE-based assay at 48 h post infection. These findings suggest that the BFVL-based assay is rapid, easy, sensitive, quantitative and specific for detection of BFV infection.

  19. Identification and functional characterization of BTas transactivator as a DNA-binding protein.

    PubMed

    Tan, Juan; Hao, Peng; Jia, Rui; Yang, Wei; Liu, Ruichang; Wang, Jinzhong; Xi, Zhen; Geng, Yunqi; Qiao, Wentao

    2010-09-30

    The genome of bovine foamy virus (BFV) encodes a transcriptional transactivator, namely BTas, that remarkably enhances gene expression by binding to the viral long-terminal repeat promoter (LTR) and internal promoter (IP). In this report, we characterized the functional domains of BFV BTas. BTas contains two major functional domains: the N-terminal DNA-binding domain (residues 1-133) and the C-terminal activation domain (residues 198-249). The complete BTas responsive regions were mapped to the positions -380/-140 of LTR and 9205/9276 of IP. Four BTas responsive elements were identified at the positions -368/-346, -327/-307, -306/-285 and -186/-165 of the BFV LTR, and one element was identified at the position 9243/9264 of the BFV IP. Unlike other foamy viruses, the five BTas responsive elements in BFV shared obvious sequence homology. These data suggest that among the complex retroviruses, BFV appears to have a unique transactivation mechanism. Crown Copyright 2010. Published by Elsevier Inc. All rights reserved.

  20. Antinociceptive, anti-inflammatory and antiarthritic activities of Bungarus fasciatus venom in experimental animal models.

    PubMed

    Ghosh, Susmita; Saha, Partha Pratim; Dasgupta, Subir C; Gomes, Antony

    2016-09-01

    Pain and inflammation are intimately associated with rheumatoid arthritis, a growing bone-joint related problem of the modern society. Though several therapeutic managements are available for arthritis, their side effects not only limit their use, but also advocate the quest for natural therapies. In this study, we explored the antinociceptive, anti-inflammatory and antiarthritic activities of Bungarus fasciatus venom (BFV) in experimental animal models. Rheumatoid arthritis was induced by Freund’s complete adjuvant (FCA) in male Wistar albino rats. Lyophilized BFV was diluted in 0.9% NaCl. Antiarthritic activity showed that BFV significantly reduced the paw and ankle diameters; urinary hydroxyproline, glucosamine levels and serum ACP/ALP/TNF-α/IL-1β/IL-17/Cathepsin-K/MMP-1 levels. These parameters were significantly increased in FCA induced arthritic animals. Joint histopathology study indicated the partial restoration of joint structure. Treatment with BFV significantly reduced the mean latency time of tail flick response, acetic acid induced writhing response and formalin induced licking response in male albino mice. BFV treatment also significantly reduced carrageenan induced paw edema and xylene induced ear edema in male albino mice. The results indicated that BFV possess antinociceptive, anti-inflammatory and antiarthritic properties and further studies are warranted to find the active constituents present in BFV.

  1. In Vitro Evolution of Bovine Foamy Virus Variants with Enhanced Cell-Free Virus Titers and Transmission.

    PubMed

    Bao, Qiuying; Hipp, Michaela; Hugo, Annette; Lei, Janet; Liu, Yang; Kehl, Timo; Hechler, Torsten; Löchelt, Martin

    2015-11-11

    Virus transmission is essential for spreading viral infections and is a highly coordinated process which occurs by cell-free transmission or cell-cell contact. The transmission of Bovine Foamy Virus (BFV) is highly cell-associated, with undetectable cell-free transmission. However, BFV particle budding can be induced by overexpression of wild-type (wt) BFV Gag and Env or artificial retargeting of Gag to the plasma membrane via myristoylation membrane targeting signals, closely resembling observations in other foamy viruses. Thus, the particle release machinery of wt BFV appears to be an excellent model system to study viral adaption to cell-free transmission by in vitro selection and evolution. Using selection for BFV variants with high cell-free infectivity in bovine and non-bovine cells, infectivity dramatically increased from almost no infectious units to about 105-106 FFU (fluorescent focus forming units)/mL in both cell types. Importantly, the selected BFV variants with high titer (HT) cell-free infectivity could still transmit via cell-cell contacts and were neutralized by serum from naturally infected cows. These selected HT-BFV variants will shed light into virus transmission and potential routes of intervention in the spread of viral infections. It will also allow the improvement or development of new promising approaches for antiretroviral therapies.

  2. In Vitro Evolution of Bovine Foamy Virus Variants with Enhanced Cell-Free Virus Titers and Transmission

    PubMed Central

    Bao, Qiuying; Hipp, Michaela; Hugo, Annette; Lei, Janet; Liu, Yang; Kehl, Timo; Hechler, Torsten; Löchelt, Martin

    2015-01-01

    Virus transmission is essential for spreading viral infections and is a highly coordinated process which occurs by cell-free transmission or cell–cell contact. The transmission of Bovine Foamy Virus (BFV) is highly cell-associated, with undetectable cell-free transmission. However, BFV particle budding can be induced by overexpression of wild-type (wt) BFV Gag and Env or artificial retargeting of Gag to the plasma membrane via myristoylation membrane targeting signals, closely resembling observations in other foamy viruses. Thus, the particle release machinery of wt BFV appears to be an excellent model system to study viral adaption to cell-free transmission by in vitro selection and evolution. Using selection for BFV variants with high cell-free infectivity in bovine and non-bovine cells, infectivity dramatically increased from almost no infectious units to about 105–106 FFU (fluorescent focus forming units)/mL in both cell types. Importantly, the selected BFV variants with high titer (HT) cell-free infectivity could still transmit via cell-cell contacts and were neutralized by serum from naturally infected cows. These selected HT–BFV variants will shed light into virus transmission and potential routes of intervention in the spread of viral infections. It will also allow the improvement or development of new promising approaches for antiretroviral therapies. PMID:26569290

  3. Weather variability, tides, and Barmah Forest virus disease in the Gladstone region, Australia.

    PubMed

    Naish, Suchithra; Hu, Wenbiao; Nicholls, Neville; Mackenzie, John S; McMichael, Anthony J; Dale, Pat; Tong, Shilu

    2006-05-01

    In this study we examined the impact of weather variability and tides on the transmission of Barmah Forest virus (BFV) disease and developed a weather-based forecasting model for BFV disease in the Gladstone region, Australia. We used seasonal autoregressive integrated moving-average (SARIMA) models to determine the contribution of weather variables to BFV transmission after the time-series data of response and explanatory variables were made stationary through seasonal differencing. We obtained data on the monthly counts of BFV cases, weather variables (e.g., mean minimum and maximum temperature, total rainfall, and mean relative humidity), high and low tides, and the population size in the Gladstone region between January 1992 and December 2001 from the Queensland Department of Health, Australian Bureau of Meteorology, Queensland Department of Transport, and Australian Bureau of Statistics, respectively. The SARIMA model shows that the 5-month moving average of minimum temperature (b=0.15, p-value<0.001) was statistically significantly and positively associated with BFV disease, whereas high tide in the current month (b=-1.03, p-value=0.04) was statistically significantly and inversely associated with it. However, no significant association was found for other variables. These results may be applied to forecast the occurrence of BFV disease and to use public health resources in BFV control and prevention.

  4. Forecasting the future risk of Barmah Forest virus disease under climate change scenarios in Queensland, Australia.

    PubMed

    Naish, Suchithra; Mengersen, Kerrie; Hu, Wenbiao; Tong, Shilu

    2013-01-01

    Mosquito-borne diseases are climate sensitive and there has been increasing concern over the impact of climate change on future disease risk. This paper projected the potential future risk of Barmah Forest virus (BFV) disease under climate change scenarios in Queensland, Australia. We obtained data on notified BFV cases, climate (maximum and minimum temperature and rainfall), socio-economic and tidal conditions for current period 2000-2008 for coastal regions in Queensland. Grid-data on future climate projections for 2025, 2050 and 2100 were also obtained. Logistic regression models were built to forecast the otential risk of BFV disease distribution under existing climatic, socio-economic and tidal conditions. The model was applied to estimate the potential geographic distribution of BFV outbreaks under climate change scenarios. The predictive model had good model accuracy, sensitivity and specificity. Maps on potential risk of future BFV disease indicated that disease would vary significantly across coastal regions in Queensland by 2100 due to marked differences in future rainfall and temperature projections. We conclude that the results of this study demonstrate that the future risk of BFV disease would vary across coastal regions in Queensland. These results may be helpful for public health decision making towards developing effective risk management strategies for BFV disease control and prevention programs in Queensland.

  5. Jacobi bundles and the BFV-complex

    NASA Astrophysics Data System (ADS)

    Lê, Hông Vân; Tortorella, Alfonso G.; Vitagliano, Luca

    2017-11-01

    We extend the construction of the BFV-complex of a coisotropic submanifold from the Poisson setting to the Jacobi setting. In particular, our construction applies in the contact and l.c.s. settings. The BFV-complex of a coisotropic submanifold S controls the coisotropic deformation problem of S under both Hamiltonian and Jacobi equivalence.

  6. Transforming Mechanized Reconnaissance: How the Armored Brigade Combat Team (ABCT) Cavalry Squadron Should be Structured for Reconnaissance and Security Operations in the Near Future

    DTIC Science & Technology

    2014-06-13

    Squadron ( BFV /HMMWV, Current) .................................................. 93 Description...Evaluation Criteria ........................................................ 106 Comparison to Validation Criteria: ABCT Cavalry Squadron ( BFV /HMMWV...Brigade Combat Team BFV Bradley Fighting Vehicle BRT Brigade Reconnaissance Troop CAB Combined Arms Battalion CFV Cavalry Fighting Vehicle FM

  7. Barmah Forest virus serology; implications for diagnosis and public health action.

    PubMed

    Cashman, Patrick; Hueston, Linda; Durrheim, David; Massey, Peter; Doggett, Stephen; Russell, Richard C

    2008-06-01

    Barmah Forest virus (BFV) is a commonly occurring arbovirus in Australia. Notifications of Barmah Forest infections diagnosed by a single positive IgM serology test have been increasing in coastal New South Wales north of Newcastle. We report on a 6 month prospective review of all routine notifications of BFV from the Lower Mid North Coast of New South Wales. Sera from 37 consecutive cases were sent for confirmatory testing by ELISA and neutralisation assays and 32 cases were interviewed. On confirmatory testing, 7 patients' sera (19%) was found to contain no BFV antibodies and 6 (16%) had BFV IgG only. Only 4 cases had antibody levels compatible with recent infection. A clinical presentation of fever with either rash or joint pain was associated with confirmation of recent BFV infection. On the basis of these findings, caution is advised in the interpretation of a single positive IgM for Barmah Forest disease and the clinical picture is an important factor in the diagnosis. Serological notifications of BFV alone should not prompt public health action such as public warning and targeted vector control in endemic areas.

  8. Weather Variability, Tides, and Barmah Forest Virus Disease in the Gladstone Region, Australia

    PubMed Central

    Naish, Suchithra; Hu, Wenbiao; Nicholls, Neville; Mackenzie, John S.; McMichael, Anthony J.; Dale, Pat; Tong, Shilu

    2006-01-01

    In this study we examined the impact of weather variability and tides on the transmission of Barmah Forest virus (BFV) disease and developed a weather-based forecasting model for BFV disease in the Gladstone region, Australia. We used seasonal autoregressive integrated moving-average (SARIMA) models to determine the contribution of weather variables to BFV transmission after the time-series data of response and explanatory variables were made stationary through seasonal differencing. We obtained data on the monthly counts of BFV cases, weather variables (e.g., mean minimum and maximum temperature, total rainfall, and mean relative humidity), high and low tides, and the population size in the Gladstone region between January 1992 and December 2001 from the Queensland Department of Health, Australian Bureau of Meteorology, Queensland Department of Transport, and Australian Bureau of Statistics, respectively. The SARIMA model shows that the 5-month moving average of minimum temperature (β = 0.15, p-value < 0.001) was statistically significantly and positively associated with BFV disease, whereas high tide in the current month (β = −1.03, p-value = 0.04) was statistically significantly and inversely associated with it. However, no significant association was found for other variables. These results may be applied to forecast the occurrence of BFV disease and to use public health resources in BFV control and prevention. PMID:16675420

  9. Forecasting the Future Risk of Barmah Forest Virus Disease under Climate Change Scenarios in Queensland, Australia

    PubMed Central

    Naish, Suchithra; Mengersen, Kerrie; Hu, Wenbiao; Tong, Shilu

    2013-01-01

    Background Mosquito-borne diseases are climate sensitive and there has been increasing concern over the impact of climate change on future disease risk. This paper projected the potential future risk of Barmah Forest virus (BFV) disease under climate change scenarios in Queensland, Australia. Methods/Principal Findings We obtained data on notified BFV cases, climate (maximum and minimum temperature and rainfall), socio-economic and tidal conditions for current period 2000–2008 for coastal regions in Queensland. Grid-data on future climate projections for 2025, 2050 and 2100 were also obtained. Logistic regression models were built to forecast the otential risk of BFV disease distribution under existing climatic, socio-economic and tidal conditions. The model was applied to estimate the potential geographic distribution of BFV outbreaks under climate change scenarios. The predictive model had good model accuracy, sensitivity and specificity. Maps on potential risk of future BFV disease indicated that disease would vary significantly across coastal regions in Queensland by 2100 due to marked differences in future rainfall and temperature projections. Conclusions/Significance We conclude that the results of this study demonstrate that the future risk of BFV disease would vary across coastal regions in Queensland. These results may be helpful for public health decision making towards developing effective risk management strategies for BFV disease control and prevention programs in Queensland. PMID:23690959

  10. Hypocapnia and cerebral hypoperfusion in orthostatic intolerance

    NASA Technical Reports Server (NTRS)

    Novak, V.; Spies, J. M.; Novak, P.; McPhee, B. R.; Rummans, T. A.; Low, P. A.

    1998-01-01

    BACKGROUND AND PURPOSE: Orthostatic and other stresses trigger tachycardia associated with symptoms of tremulousness, shortness of breath, dizziness, blurred vision, and, often, syncope. It has been suggested that paradoxical cerebral vasoconstriction during head-up tilt might be present in patients with orthostatic intolerance. We chose to study middle cerebral artery (MCA) blood flow velocity (BFV) and cerebral vasoregulation during tilt in patients with orthostatic intolerance (OI). METHODS: Beat-to-beat BFV from the MCA, heart rate, CO2, blood pressure (BP), and respiration were measured in 30 patients with OI (25 women and 5 men; age range, 21 to 44 years; mean age, 31.3+/-1.2 years) and 17 control subjects (13 women and 4 men; age range, 20 to 41 years; mean age, 30+/-1.6 years); ages were not statistically different. These indices were monitored during supine rest and head-up tilt (HUT). We compared spontaneous breathing and hyperventilation and evaluated the effect of CO2 rebreathing in these 2 positions. RESULTS: The OI group had higher supine heart rates (P<0.001) and cardiac outputs (P<0.01) than the control group. In response to HUT, OI patients underwent a greater heart rate increment (P<0.001) and greater reductions in pulse pressure (P<0.01) and CO2 (P<0.001), but total systemic resistance failed to show an increment. Among the cerebrovascular indices, all BFVs (systolic, diastolic, and mean) decreased significantly more, and cerebrovascular resistance (CVR) was increased in OI patients (P<0.01) compared with control subjects. In both groups, hyperventilation induced mild tachycardia (P<0.001), a significant reduction of BFV, and a significant increase of CVR associated with a fall in CO2. Hyperventilation during HUT reproduced hypocapnia, BFV reduction, and tachycardia and worsened symptoms of OI; these symptoms and indices were improved within 2 minutes of CO2 rebreathing. The relationships between CO2 and BFV and heart rate were well described by linear regressions, and the slope was not different between control subjects and patients with OI. CONCLUSIONS: Cerebral vasoconstriction occurs in OI during orthostasis, which is primarily due to hyperventilation, causing significant hypocapnia. Hypocapnia and symptoms of orthostatic hypertension are reversible by CO2 rebreathing.

  11. Hypocapnia and cerebral hypoperfusion in orthostatic intolerance.

    PubMed

    Novak, V; Spies, J M; Novak, P; McPhee, B R; Rummans, T A; Low, P A

    1998-09-01

    Orthostatic and other stresses trigger tachycardia associated with symptoms of tremulousness, shortness of breath, dizziness, blurred vision, and, often, syncope. It has been suggested that paradoxical cerebral vasoconstriction during head-up tilt might be present in patients with orthostatic intolerance. We chose to study middle cerebral artery (MCA) blood flow velocity (BFV) and cerebral vasoregulation during tilt in patients with orthostatic intolerance (OI). Beat-to-beat BFV from the MCA, heart rate, CO2, blood pressure (BP), and respiration were measured in 30 patients with OI (25 women and 5 men; age range, 21 to 44 years; mean age, 31.3+/-1.2 years) and 17 control subjects (13 women and 4 men; age range, 20 to 41 years; mean age, 30+/-1.6 years); ages were not statistically different. These indices were monitored during supine rest and head-up tilt (HUT). We compared spontaneous breathing and hyperventilation and evaluated the effect of CO2 rebreathing in these 2 positions. The OI group had higher supine heart rates (P<0.001) and cardiac outputs (P<0.01) than the control group. In response to HUT, OI patients underwent a greater heart rate increment (P<0.001) and greater reductions in pulse pressure (P<0.01) and CO2 (P<0.001), but total systemic resistance failed to show an increment. Among the cerebrovascular indices, all BFVs (systolic, diastolic, and mean) decreased significantly more, and cerebrovascular resistance (CVR) was increased in OI patients (P<0.01) compared with control subjects. In both groups, hyperventilation induced mild tachycardia (P<0.001), a significant reduction of BFV, and a significant increase of CVR associated with a fall in CO2. Hyperventilation during HUT reproduced hypocapnia, BFV reduction, and tachycardia and worsened symptoms of OI; these symptoms and indices were improved within 2 minutes of CO2 rebreathing. The relationships between CO2 and BFV and heart rate were well described by linear regressions, and the slope was not different between control subjects and patients with OI. Cerebral vasoconstriction occurs in OI during orthostasis, which is primarily due to hyperventilation, causing significant hypocapnia. Hypocapnia and symptoms of orthostatic hypertension are reversible by CO2 rebreathing.

  12. Spatial-temporal epidemiological analyses of two sympatric, co-endemic alphaviral diseases in Queensland, Australia.

    PubMed

    Pelecanos, Anita M; Ryan, Peter A; Gatton, Michelle L

    2011-04-01

    The two most reported mosquito-borne diseases in Queensland, a northern state of Australia, are Ross River virus (RRV) disease and Barmah Forest virus (BFV) disease. Both diseases are endemic in Queensland and have similar clinical symptoms and comparable transmission cycles involving a complex inter-relationship between human hosts, various mosquito vectors, and a range of nonhuman vertebrate hosts, including marsupial mammals that are unique to the Australasian region. Although these viruses are thought to share similar vectors and vertebrate hosts, RRV is four times more prevalent than BFV in Queensland. We performed a retrospective analysis of BFV and RRV human disease notification data collected from 1995 to 2007 in Queensland to ascertain whether there were differences in the incidence patterns of RRV and BFV disease. In particular, we compared the temporal incidence and spatial distribution of both diseases and considered the relationship between their disease dynamics. We also investigated whether a peak in BFV incidence during spring was indicative of the following RRV and BFV transmission season incidence levels. Although there were large differences in the notification rates of the two diseases, they had similar annual temporal patterns, but there were regional variations between the length and magnitude of the transmission seasons. During periods of increased disease activity, however, there was no association between the dynamics of the two diseases. The results from this study suggest that while RRV and BFV share similar mosquito vectors, there are significant differences in the ecology of these viruses that result in different epidemic patterns of disease incidence. Further investigation is required into the ecology of each virus to determine which factors are important in promoting RRV and BFV disease outbreaks.

  13. Impaired retinal microcirculation in patients with Alzheimer’s disease

    PubMed Central

    Liu, Yi; Wei, Yantao; Shi, Yingying; Wright, Clinton B.; Sun, Xiaoyan; Rundek, Tatjana; Baumel, Bernard S.; Landman, Jonathan; Wang, Jianhua

    2018-01-01

    The goal of this study was to determine the retinal blood flow rate (BFR) and blood flow velocity (BFV) of pre-capillary arterioles and post-capillary venules in patients with mild cognitive impairment (MCI) and Alzheimer’s disease (AD). Forty patients (20 AD and 20 MCI) and 21 cognitively normal (CN) controls with a similar age range (± 5 yrs) were recruited. A retinal function imager (RFI) was used to measure BFRs and BFVs of arterioles and venules in the macular region. The thickness of the ganglion cell-inner plexiform layer (GCIPL) was measured using Zeiss Cirrus optical coherence tomography. Macular BFRs in AD group were 2.64 ± 0.20 nl/s (mean ± standard deviation) in arterioles and 2.23 ± 0.19 nl/s in venules, which were significantly lower than in MCI and CN groups (P < 0.05). In addition, BFRs in MCI were lower than in CN in both arterioles and venules (P < 0.05). The BFV of the arterioles was 3.20 ± 1.07 mm/s in AD patients, which was significantly lower than in CN controls (3.91 ± 0.77 mm/s, P = 0.01). The thicknesses of GCIPL in patients with AD and MCI were significantly lower than in CN controls (P < 0.05). Neither BFV nor BFR in arterioles and venules was related to age, GCIPL thickness, mini mental state examination (MMSE) score and disease duration in patients with AD and MCI (P > 0.05). The lower BFR in both arterioles and venules in AD and MCI patients together with the loss of GCIPL were evident, indicating the impairment of the two components in the neurovascular-hemodynamic system, which may play a role in disease progression. PMID:29394263

  14. BFV-BRST analysis of the classical and quantum q-deformations of the sl(2) algebra

    NASA Astrophysics Data System (ADS)

    Dayi, O. F.

    1994-01-01

    BFV--BRST charge for q-deformed algebras is not unique. Different constructions of it in the classical as well as in the quantum phase space for the $q$-deformed algebra sl_q(2) are discussed. Moreover, deformation of the phase space without deforming the generators of sl(2) is considered. $\\hbar$-q-deformation of the phase space is shown to yield the Witten's second deformation. To study the BFV--BRST cohomology problem when both the quantum phase space and the group are deformed, a two parameter deformation of sl(2) is proposed, and its BFV-BRST charge is given.

  15. Lysine acetylation sites in bovine foamy virus transactivator BTas are important for its DNA binding activity.

    PubMed

    Chang, Rui; Tan, Juan; Xu, Fengwen; Han, Hongqi; Geng, Yunqi; Li, Yue; Qiao, Wentao

    2011-09-15

    Cellular acetylation signaling is important for viral gene regulation, particularly during the transactivation of retroviruses. The regulatory protein of bovine foamy virus (BFV), BTas, is a transactivator that augments viral gene transcription from both the long terminal repeat (LTR) promoter and the internal promoter (IP). In this study, we report that the histone acetyltransferase (HAT), p300, specifically acetylates BTas both in vivo and in vitro. Further studies demonstrated that BTas acetylation markedly enhances its transactivation activity. Mutagenesis analysis identified three lysines at positions 66, 109 and 110 in BTas that are acetylated by p300. The K110R mutant lost its binding to BFV promoter as well as its ability to activate BFV promoter. The acetylation of K66 and K109 may contribute to increased BTas binding ability. These results suggest that the p300-acetylated lysines of BTas are important for transactivation of BFV promoters and therefore have an important role in BFV replication. Copyright © 2011 Elsevier Inc. All rights reserved.

  16. Space of states in operator BFV-formalism

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Batalin, I.A.; Tyutin, I.V.

    1993-05-15

    The dynamically adequate Fock realization of the extended space of asymptotic states is given within the framework of the operator BFV-formalism and of the Dirac quantization scheme as well. Physical subspace is picked out and established to be naturally isomorphic to the Dirac space of states. The formal mechanism (unitary [var epsilon]-limit), by means of which the operator BFV-dynamics reduces to the Dirac one, is studied. 10 refs.

  17. BV-BFV approach to general relativity: Einstein-Hilbert action

    NASA Astrophysics Data System (ADS)

    Cattaneo, Alberto S.; Schiavina, Michele

    2016-02-01

    The present paper shows that general relativity in the Arnowitt-Deser-Misner formalism admits a BV-BFV formulation. More precisely, for any d + 1 ≠ 2 (pseudo-) Riemannian manifold M with space-like or time-like boundary components, the BV data on the bulk induces compatible BFV data on the boundary. As a byproduct, the usual canonical formulation of general relativity is recovered in a straightforward way.

  18. Lysine residues K66, K109, and K110 in the bovine foamy virus transactivator protein are required for transactivation and viral replication.

    PubMed

    Zhang, Suzhen; Cui, Xiaoxu; Li, Jing; Liang, Zhibin; Qiao, Wentao; Tan, Juan

    2016-04-01

    Bovine foamy virus (BFV) is a complex retrovirus that infects cattle. Like all retroviruses, BFV encodes a transactivator Tas protein (BTas) that increases gene transcription from viral promoters. BFV encodes two promoters that can interact with BTas, a conserved promoter in the 5' long terminal repeat (LTR) and a unique internal promoter (IP). Our previous study showed that BTas is acetylated by p300 at residues K66, K109, and K110, which markedly enhanced the ability of BTas to bind to DNA. However, whether these residues are important for BFV replication was not determined. Therefore, in this study we provide direct evidence that BTas is required for BFV replication and demonstrate that residues K66, K109, and K110 are critical for BTas function and BFV replication. Full-length infectious clones were generated, which were BTas deficient or contained lysine to arginine (K→R) mutations at position 66, 109, and/or 110. In vivo data indicated that K→R mutations at positions 66, 109, and 110 in BTas impaired transactivation of both the LTR and IP promoters. In addition, the K→R mutations in full-length infectious clones reduced expression of viral proteins, and the triple mutant and BTas deletion completely abrogated viral replication. Taken together, these results indicate that lysine residues at positions 66, 109, and 110 in the BTas protein are crucial for BFV replication and suggest a potential role for BTas acetylation in regulating the viral life cycle.

  19. BRST-BFV method for nonstationary systems

    NASA Astrophysics Data System (ADS)

    García, J. Antonio; Vergara, J. David; Urrutia, Luis F.

    1995-05-01

    Starting from an associated reparametrization-invariant action, the generalization of the BRST-BFV method for the case of nonstationary systems is constructed. The extension of the Batalin-Tyutin conversional approach is also considered in the nonstationary case. In order to illustrate these ideas, the propagator for the time-dependent two-dimensional rotor is calculated by reformulating the problem as a system with only first-class constraints and subsequently using the BRST-BFV prescription previously obtained.

  20. Retinal Microvascular Network and Microcirculation Assessments in High Myopia.

    PubMed

    Li, Min; Yang, Ye; Jiang, Hong; Gregori, Giovanni; Roisman, Luiz; Zheng, Fang; Ke, Bilian; Qu, Dongyi; Wang, Jianhua

    2017-02-01

    To investigate the changes of the retinal microvascular network and microcirculation in high myopia. A cross-sectional, matched, comparative clinical study. Twenty eyes of 20 subjects with nonpathological high myopia (28 ± 5 years of age) with a refractive error of -6.31 ± 1.23 D (mean ± SD) and 20 eyes of 20 age- and sex-matched control subjects (30 ± 6 years of age) with a refractive error of -1.40 ± 1.00 D were recruited. Optical coherence tomography angiography (OCTA) was used to image the retinal microvascular network, which was later quantified by fractal analysis (box counting [D box ], representing vessel density) in both superficial and deep vascular plexuses. The Retinal Function Imager was used to image the retinal microvessel blood flow velocity (BFV). The BFV and microvascular density in the myopia group were corrected for ocular magnification using Bennett's formula. The density of both superficial and deep microvascular plexuses was significantly decreased in the myopia group in comparison to the controls (P < .05). The decrease of the microvessel density of the annular zone (0.6-2.5 mm), measured as D box , was 2.1% and 2.9% in the superficial and deep vascular plexuses, respectively. Microvessel density reached a plateau from 0.5 mm to 1.25 mm from the fovea in both groups, but that in the myopic group was about 3% lower than the control group. No significant differences were detected between the groups in retinal microvascular BFV in either arterioles or venules (P > .05). Microvascular densities in both superficial (r = -0.45, P = .047) and deep (r = -0.54, P = .01) vascular plexuses were negatively correlated with the axial lengths in the myopic eye. No correlations were observed between BFV and vessel density (P > .05). Retinal microvascular decrease was observed in the high myopia subjects, whereas the retinal microvessel BFV remained unchanged. The retinal microvascular network alteration may be attributed to ocular elongation that occurs with the progression of myopia. The novel quantitative analyses of the retinal microvasculature may help to characterize the underlying pathophysiology of myopia and enable early detection and prevention of myopic retinopathy. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Bovine Foamy Virus Transactivator BTas Interacts with Cellular RelB To Enhance Viral Transcription▿

    PubMed Central

    Wang, Jian; Tan, Juan; Guo, Hongyan; Zhang, Qicheng; Jia, Rui; Xu, Xuan; Geng, Yunqi; Qiao, Wentao

    2010-01-01

    Viruses are obligate intracellular parasites that depend on cellular machinery for their efficient transcription and replication. In a previous study we reported that bovine foamy virus (BFV) is able to activate the nuclear factor κB (NF-κB) pathway through the action of its transactivator BTas to enhance viral transcription. However, the mechanism used by NF-κB to enhance BFV transcription remains elusive. To address this question, we employed a yeast two-hybrid assay to screen for BTas-interacting proteins. We found that RelB, a member of NF-κB protein family, interacts with BTas. We confirmed the putative RelB-BTas interaction in vitro and in vivo and identified the protein regions responsible for the RelB-BTas interaction. Using a luciferase reporter assay, we next showed that RelB enhances BFV transcription (BTas-induced long terminal repeat [LTR] transactivation) and that this process requires both the localization of the RelB-BTas interaction in the nucleus and the Rel homology domain of RelB. The knockdown of the cellular endogenous RelB protein using small interfering RNA (siRNA) significantly attenuated BTas-induced LTR transcription. The results of chromatin immunoprecipitation (ChIP) analysis showed that endogenous RelB binds to the viral LTR in BFV-infected cells. Together, these results suggest that BFV engages the RelB protein as a cotransactivator of BTas to enhance viral transcription. In addition, our findings indicate that BFV infection upregulates cellular RelB expression through BTas-induced NF-κB activation. Thus, this study demonstrates the existence of a positive-feedback circuit in which BFV utilizes the host's NF-κB pathway through the RelB protein for efficient viral transcription. PMID:20844054

  2. Bovine foamy virus transactivator BTas interacts with cellular RelB to enhance viral transcription.

    PubMed

    Wang, Jian; Tan, Juan; Guo, Hongyan; Zhang, Qicheng; Jia, Rui; Xu, Xuan; Geng, Yunqi; Qiao, Wentao

    2010-11-01

    Viruses are obligate intracellular parasites that depend on cellular machinery for their efficient transcription and replication. In a previous study we reported that bovine foamy virus (BFV) is able to activate the nuclear factor κB (NF-κB) pathway through the action of its transactivator BTas to enhance viral transcription. However, the mechanism used by NF-κB to enhance BFV transcription remains elusive. To address this question, we employed a yeast two-hybrid assay to screen for BTas-interacting proteins. We found that RelB, a member of NF-κB protein family, interacts with BTas. We confirmed the putative RelB-BTas interaction in vitro and in vivo and identified the protein regions responsible for the RelB-BTas interaction. Using a luciferase reporter assay, we next showed that RelB enhances BFV transcription (BTas-induced long terminal repeat [LTR] transactivation) and that this process requires both the localization of the RelB-BTas interaction in the nucleus and the Rel homology domain of RelB. The knockdown of the cellular endogenous RelB protein using small interfering RNA (siRNA) significantly attenuated BTas-induced LTR transcription. The results of chromatin immunoprecipitation (ChIP) analysis showed that endogenous RelB binds to the viral LTR in BFV-infected cells. Together, these results suggest that BFV engages the RelB protein as a cotransactivator of BTas to enhance viral transcription. In addition, our findings indicate that BFV infection upregulates cellular RelB expression through BTas-induced NF-κB activation. Thus, this study demonstrates the existence of a positive-feedback circuit in which BFV utilizes the host's NF-κB pathway through the RelB protein for efficient viral transcription.

  3. Ross River virus and Barmah Forest virus infections: a review of history, ecology, and predictive models, with implications for tropical northern Australia.

    PubMed

    Jacups, Susan P; Whelan, Peter I; Currie, Bart J

    2008-04-01

    The purpose of the present article is to present a review of the Ross River virus (RRV) and Barmah Forest virus (BFV) literature in relation to potential implications for future disease in tropical northern Australia. Ross River virus infection is the most common and most widespread arboviral disease in Australia, with an average of 4,800 national notifications annually. Of recent concern is the sudden rise in BFV infections; the 2005-2006 summer marked the largest BFV epidemic on record in Australia, with 1,895 notifications. Although not life-threatening, infection with either virus can cause arthritis, myalgia, and fatigue for 6 months or longer, resulting in substantial morbidity and economic impact. The geographic distribution of mosquito species and their seasonal activity is determined in large part by temperature and rainfall. Predictive models can be useful tools in providing early warning systems for epidemics of RRV and BFV infection. Various models have been developed to predict RRV outbreaks, but these appear to be mostly only regionally valid, being dependent on local ecological factors. Difficulties have arisen in developing useful models for the tropical northern parts of Australia, and to date no models have been developed for the Northern Territory. Only one model has been developed for predicting BFV infections using climate and tide variables. It is predicted that the exacerbation of current greenhouse conditions will result in longer periods of high mosquito activity in the tropical regions where RRV and BFV are already common. In addition, the endemic locations may expand further within temperate regions, and epidemics may become more frequent in those areas. Further development of predictive models should benefit public health planning by providing early warning systems of RRV and BFV infection outbreaks in different geographical locations.

  4. Does the Defense Industrial Base Environment Create Strategic Risk?

    DTIC Science & Technology

    2013-03-01

    Defense Authorization Act (NDAA) that concerns the production of the M1 Abrams Main Battle Tank (MBT), Bradley Fighting Vehicle ( BFV ) and Hercules...34 This instance highlights how Congress is mandating the production of M1 and BFV to maintain these sectors of the DIB, however this method is...mandate to continue production of the M1 Abrams, the BFV and the Hercules recovery vehicle.76 The challenges this action presents is the Army will have

  5. Understanding why a Ground Combat Vehicle that Carries Nine Dismounts is Important to the Army

    DTIC Science & Technology

    2013-01-01

    BFV Bradley Fighting Vehicle BLUF Bottom Line Up Front BMP Boyevaya Mashina Pekhoty (infantry fighting vehicle) COIN counterinsurgency DIV 86...the introduction of the Bradley Fighting Vehicle ( BFV ).15 It is important to note that the standardization of the nine-man infantry squad resulting...integrated the BFV into its mechanized infantry formations. 29 Today’s squad with nine soldiers is smaller by two than the mid-50s squad but is otherwise

  6. Built to Last: The Army’s Failed Quest to Replace the Bradley Fighting Vehicle

    DTIC Science & Technology

    2015-05-23

    Army believes that the BFV does not have the space, weight, or power needed on the modern battlefield. The persistent need for a replacement vehicle...the early 1980’s. The Army has long expressed the need to replace the Bradley Fighting Vehicle ( BFV ) with a new ground combat vehicle. The Bradley...one of the original Big Five, was designed to fight a Cold War threat. Requirements have changed since then but the Army continues to use the BFV

  7. BFV-BRST analysis of equivalence between noncommutative and ordinary gauge theories

    NASA Astrophysics Data System (ADS)

    Dayi, O. F.

    2000-05-01

    Constrained hamiltonian structure of noncommutative gauge theory for the gauge group /U(1) is discussed. Constraints are shown to be first class, although, they do not give an Abelian algebra in terms of Poisson brackets. The related BFV-BRST charge gives a vanishing generalized Poisson bracket by itself due to the associativity of /*-product. Equivalence of noncommutative and ordinary gauge theories is formulated in generalized phase space by using BFV-BRST charge and a solution is obtained. Gauge fixing is discussed.

  8. Success and Failure in Doctrinal Innovation: A Comparison of the U.S. Army Medical Department and Logistics Branch, 1990- 2010

    DTIC Science & Technology

    2012-03-01

    Treatment Vehicle ARFORGEN Army Force AR Army Regulation ARTEP Army AXP Ambulance Exchange Point BCT Brigade Combat Team BDE Brigade BFV ...program, with newer versions of Abrams tanks and Bradley fighting vehicles ( BFV ), which further exacerbated the already slow Vietnam-era medical...DoD agencies on yet another revision of the cancelled AMEV design based on the BFV . The Army began investigating the need for a newer ambulance

  9. Relational symplectic groupoid quantization for constant poisson structures

    NASA Astrophysics Data System (ADS)

    Cattaneo, Alberto S.; Moshayedi, Nima; Wernli, Konstantin

    2017-09-01

    As a detailed application of the BV-BFV formalism for the quantization of field theories on manifolds with boundary, this note describes a quantization of the relational symplectic groupoid for a constant Poisson structure. The presence of mixed boundary conditions and the globalization of results are also addressed. In particular, the paper includes an extension to space-times with boundary of some formal geometry considerations in the BV-BFV formalism, and specifically introduces into the BV-BFV framework a "differential" version of the classical and quantum master equations. The quantization constructed in this paper induces Kontsevich's deformation quantization on the underlying Poisson manifold, i.e., the Moyal product, which is known in full details. This allows focussing on the BV-BFV technology and testing it. For the inexperienced reader, this is also a practical and reasonably simple way to learn it.

  10. Quantum localization of classical mechanics

    NASA Astrophysics Data System (ADS)

    Batalin, Igor A.; Lavrov, Peter M.

    2016-07-01

    Quantum localization of classical mechanics within the BRST-BFV and BV (or field-antifield) quantization methods are studied. It is shown that a special choice of gauge fixing functions (or BRST-BFV charge) together with the unitary limit leads to Hamiltonian localization in the path integral of the BRST-BFV formalism. In turn, we find that a special choice of gauge fixing functions being proportional to extremals of an initial non-degenerate classical action together with a very special solution of the classical master equation result in Lagrangian localization in the partition function of the BV formalism.

  11. Gauge fixing and BFV quantization

    NASA Astrophysics Data System (ADS)

    Rogers, Alice

    2000-01-01

    Non-singularity conditions are established for the Batalin-Fradkin-Vilkovisky (BFV) gauge-fixing fermion which are sufficient for it to lead to the correct path integral for a theory with constraints canonically quantized in the BFV approach. The conditions ensure that the anticommutator of this fermion with the BRST charge regularizes the path integral by regularizing the trace over non-physical states in each ghost sector. The results are applied to the quantization of a system which has a Gribov problem, using a non-standard form of the gauge-fixing fermion.

  12. Impact of the National Debt on United States Army Funding

    DTIC Science & Technology

    2013-03-01

    GCV) to replace the Bradley Fighting Vehicle ( BFV ). In FY13 the Army has budgeted $640M which increases to over $1B by FY16. By reducing the funding...to delay the development of the CGV by a few years. The BFV is still a good vehicle and variants are expected to be in the Army inventory until 2040...the majority of the BFV fleet has been reset back to zero miles coming out of Iraq. With the Army also facing future force structure reductions, a

  13. Efficiencies from Applying a Rotational Equipping Strategy

    DTIC Science & Technology

    2011-01-01

    Washington, D.C.: United States Government Accountability Office, 2007. NOTES: BFV = Bradley Fighting Vehicle, HEMTT = heavy expanded mobility tactical...of Its Equipment Reset Strategy, Washington, D.C.: United States Government Accountability Office, 2007. NOTES: BFV = Bradley Fighting Vehicle

  14. On Correspondence of BRST-BFV, Dirac, and Refined Algebraic Quantizations of Constrained Systems

    NASA Astrophysics Data System (ADS)

    Shvedov, O. Yu.

    2002-11-01

    The correspondence between BRST-BFV, Dirac, and refined algebraic (group averaging, projection operator) approaches to quantizing constrained systems is analyzed. For the closed-algebra case, it is shown that the component of the BFV wave function corresponding to maximal (minimal) value of number of ghosts and antighosts in the Schrodinger representation may be viewed as a wave function in the refined algebraic (Dirac) quantization approach. The Giulini-Marolf group averaging formula for the inner product in the refined algebraic quantization approach is obtained from the Batalin-Marnelius prescription for the BRST-BFV inner product, which should be generally modified due to topological problems. The considered prescription for the correspondence of states is observed to be applicable to the open-algebra case. The refined algebraic quantization approach is generalized then to the case of nontrivial structure functions. A simple example is discussed. The correspondence of observables for different quantization methods is also investigated.

  15. Chern-Simons theory with Wilson lines and boundary in the BV-BFV formalism

    NASA Astrophysics Data System (ADS)

    Alekseev, Anton; Barmaz, Yves; Mnev, Pavel

    2013-05-01

    We consider the Chern-Simons theory with Wilson lines in 3D and in 1D in the BV-BFV formalism of Cattaneo-Mnev-Reshetikhin. In particular, we allow for Wilson lines to end on the boundary of the space-time manifold. In the toy model of 1D Chern-Simons theory, the quantized BFV boundary action coincides with the Kostant cubic Dirac operator which plays an important role in representation theory. In the case of 3D Chern-Simons theory, the boundary action turns out to be the odd (degree 1) version of the BF model with source terms for the B field at the points where the Wilson lines meet the boundary. The boundary space of states arising as the cohomology of the quantized BFV action coincides with the space of conformal blocks of the corresponding WZW model.

  16. Surveillance should be strengthened to improve epidemiological understandings of mosquito-borne Barmah Forest virus infection.

    PubMed

    Ehlkes, Lutz; Eastwood, Keith; Webb, Cameron; Durrheim, David

    2012-07-01

    Barmah Forest virus (BFV) is a mosquito-borne virus causing epidemic polyarthritis in Australia. This study used case follow-up of cases from the surveillance system to demonstrate that routinely collected BFV notification data were an unreliable indicator of the true location of exposure. BFV notifications from June 2001 to May 2011 were extracted from the New South Wales (NSW) Notifiable Conditions Information Management System to study case distribution. Disease cluster analysis was performed using spatial scan statistics. Exposure history data were collected from cases notified in 2010 and 2011 to accurately determine travel to high-risk areas. Cluster analysis using address data identified an area of increased BFV disease incidence in the mid-north coast of NSW contiguous with estuarine wetlands. When travel to this area was investigated, 96.7% (29/30) cases reported having visited coastal regions within four weeks of developing symptoms. Along the central NSW coastline, extensive wetlands occur in close proximity to populated areas. These wetlands provide ideal breeding habitats for a range of mosquito species implicated in the transmission of BFV. This is the first study to fully assess case exposure with findings suggesting that sporadic cases of BFV in people living further away from the coast do not reflect alternative exposure sites but are likely to result from travel to coastal regions. Spatial analysis by case address alone may lead to inaccurate understandings of the true distribution of arboviral diseases. Subsequently, this information has important implications for the collection of mosquito-borne disease surveillance information and public health response strategies.

  17. [Renal arterial spin labeling magnetic resonance imaging in normal adults: a study with a 3.0 T scanner].

    PubMed

    Zhang, Fan; Zhang, Xuelin; Yang, Li; Shen, Jie; Gao, Wei

    2013-10-01

    To analyze the renal relative blood flow value (rBFV) and image quality in normal adults using single-shot fast spin echo, flow sensitive invention recovery (SSFSE-FAIR) magnetic resonance (MR) sequence and echo planar imaging, and flow sensitive invention recovery (EPI-FAIR) MR sequence, and assess its value for clinical application in routine renal examination. Forty volunteers (25 male and 15 female adults, aged 30 to 62 years) with normal renal function were included in this prospective study. All the subjects underwent 3.0 Tesla MR scanning using 3 MR scan modes, namely breath-holding EPI-FAIR, breath-holding SSFSE-FAIR and free breathing SSFSE-FAIR. SSFSE-FAIR without breath-holding was capable of differentiating the renal cortex and medulla with the corresponding rBFVs of 111.48∓9.23 and 94.98∓3.38, respectively. Breath-holding SSFSE-FAIR and EPI-FAIR failed to distinguish the borders of the renal cortex and medulla. The EPI-FAIR rBFV of mixed cortex and medulla value was 178.50∓17.17 (95%CI: 167.59, 189.41). Breath-holding SSFSE-FAIR and EPI-FAIR can not distinguish the renal cortex and medulla due to a poor spatial resolution but can be used for rough evaluation of renal blood perfusion. Free breathing SSFSE-FAIR with an improved spatial resolution allows evaluation of the status of renal perfusion of the cortex and medulla.

  18. Field-antifield and BFV formalisms for quadratic systems with open gauge algebras

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nirov, K.S.; Razumov, A.V.

    1992-09-20

    In this paper the Lagrangian field-antifield (BV) and Hamiltonian (BFV) BRST formalisms for the general quadratic systems with open gauge algebra are considered. The equivalence between the Lagrangian and Hamiltonian formalisms is proven.

  19. Bfv Quantization of Relativistic Spinning Particles with a Single Bosonic Constraint

    NASA Astrophysics Data System (ADS)

    Rabello, Silvio J.; Vaidya, Arvind N.

    Using the BFV approach we quantize a pseudoclassical model of the spin-1/2 relativistic particle that contains a single bosonic constraint, contrary to the usual locally supersymmetric models that display first and second class constraints.

  20. Quantization of Spontaneously Broken Gauge Theory Based on the Bft-Bfv Formalism

    NASA Astrophysics Data System (ADS)

    Kim, Yong-Wan; Park, Young-Jai

    We quantize the spontaneously broken Abelian U(1) Higgs model by using the improved BFT and BFV formalisms. We construct the BFT physical fields and obtain the firstclass observables including the Hamiltonian in terms of these fields. We also explicitly show that there are exact form invariances between the second-class and first-class quantities. Then, according to the BFV formalism, we derive the corresponding Lagrangian having U(1) gauge symmetry. We also discuss at the classical level how one easily gets the first-class Lagrangian from the symmetry-broken second-class Lagrangian.

  1. Batalin-Fradkin-Vilkovisky approach for a nonlocal symmetry of QED

    NASA Astrophysics Data System (ADS)

    Rabello, Silvio J.; Gaete, Patricio

    1995-12-01

    In this paper we use the Batalin-Fradkin-Vilkovisky (BFV) formalism to study a recently proposed nonlocal symmetry of QED. In the BFV extended phase space we show that this symmetry stems from a canonical transformation in the ghost sector.

  2. Capability Portfolio Analysis Tool (CPAT) Verification and Validation Report

    DTIC Science & Technology

    2013-01-01

    BFSB Battlefield Surveillance Brigade BFV Bradley Fighting Vehicle BMOD Bradley Modernization C2 (H) Command and Control (HBCT) C2 (S...Fire Infantry Fighting Vehicle (IFV); Fire Integrated Support Team (FIST); Engineer (Eng); Cavalry (CAV) BFV FOV CDD Block II - 16 Apr 2010 GCV FOV

  3. BRST-BFV analysis of anomalies in bosonic string theory interacting with background gravitational field

    NASA Astrophysics Data System (ADS)

    Buchbinder, I. L.; Mistchuk, B. R.; Pershin, V. D.

    1995-02-01

    A general BRST-BFV analysis of the anomaly in string theory coupled to background fields is carried out. An exact equation for the c-valued symbol of the anomaly operator is found and the structure of its solution is studied.

  4. Batalin-Fradkin-Vilkovisky approach for a nonlocal symmetry of QED

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rabello, S.J.; Gaete, P.

    1995-12-15

    In this paper we use the Batalin-Fradkin-Vilkovisky (BFV) formalism to study a recently proposed nonlocal symmetry of QED. In the BFV extended phase space we show that this symmetry stems from a canonical transformation in the ghost sector. {copyright} 1995 The American Physical Society.

  5. A systematic study of finite BRST-BFV transformations in generalized Hamiltonian formalism

    NASA Astrophysics Data System (ADS)

    Batalin, Igor A.; Lavrov, Peter M.; Tyutin, Igor V.

    2014-09-01

    We study systematically finite BRST-BFV transformations in the generalized Hamiltonian formalism. We present explicitly their Jacobians and the form of a solution to the compensation equation determining the functional field dependence of finite Fermionic parameters, necessary to generate an arbitrary finite change of gauge-fixing functions in the path integral.

  6. Finite BRST-BFV transformations for dynamical systems with second-class constraints

    NASA Astrophysics Data System (ADS)

    Batalin, Igor A.; Lavrov, Peter M.; Tyutin, Igor V.

    2015-06-01

    We study finite field-dependent BRST-BFV transformations for dynamical systems with first- and second-class constraints within the generalized Hamiltonian formalism. We find explicitly their Jacobians and the form of a solution to the compensation equation necessary for generating an arbitrary finite change of gauge-fixing functionals in the path integral.

  7. Early whole-brain CT perfusion for detection of patients at risk for delayed cerebral ischemia after subarachnoid hemorrhage.

    PubMed

    Malinova, Vesna; Dolatowski, Karoline; Schramm, Peter; Moerer, Onnen; Rohde, Veit; Mielke, Dorothee

    2016-07-01

    OBJECT This prospective study investigated the role of whole-brain CT perfusion (CTP) studies in the identification of patients at risk for delayed ischemic neurological deficits (DIND) and of tissue at risk for delayed cerebral infarction (DCI). METHODS Forty-three patients with aneurysmal subarachnoid hemorrhage (aSAH) were included in this study. A CTP study was routinely performed in the early phase (Day 3). The CTP study was repeated in cases of transcranial Doppler sonography (TCD)-measured blood flow velocity (BFV) increase of > 50 cm/sec within 24 hours and/or on Day 7 in patients who were intubated/sedated. RESULTS Early CTP studies revealed perfusion deficits in 14 patients, of whom 10 patients (72%) developed DIND, and 6 of these 10 patients (60%) had DCI. Three of the 14 patients (21%) with early perfusion deficits developed DCI without having had DIND, and the remaining patient (7%) had neither DIND nor DCI. There was a statistically significant correlation between early perfusion deficits and occurrence of DIND and DCI (p < 0.0001). A repeated CTP was performed in 8 patients with a TCD-measured BFV increase > 50 cm/sec within 24 hours, revealing a perfusion deficit in 3 of them (38%). Two of the 3 patients (67%) developed DCI without preceding DIND and 1 patient (33%) had DIND without DCI. In 4 of the 7 patients (57%) who were sedated and/or comatose, additional CTP studies on Day 7 showed perfusion deficits. All 4 patients developed DCI. CONCLUSIONS Whole-brain CTP on Day 3 after aSAH allows early and reliable identification of patients at risk for DIND and tissue at risk for DCI. Additional CTP investigations, guided by TCD-measured BFV increase or persisting coma, do not contribute to information gain.

  8. A systematic study of finite BRST-BFV transformations in Sp(2)-extended generalized Hamiltonian formalism

    NASA Astrophysics Data System (ADS)

    Batalin, Igor A.; Lavrov, Peter M.; Tyutin, Igor V.

    2014-09-01

    We study systematically finite BRST-BFV transformations in Sp(2)-extended generalized Hamiltonian formalism. We present explicitly their Jacobians and the form of a solution to the compensation equation determining the functional field dependence of finite Fermionic parameters, necessary to generate arbitrary finite change of gauge-fixing functions in the path integral.

  9. Tear Down and Inspection of the Cummins VTA-903 Evaluated Using the Single Common Powertrain Lubricant SCPL

    DTIC Science & Technology

    2013-12-13

    Materials AT Anti-Thrust AVG Average BFV Bradley Fighting Vehicle CAT Caterpillar EOT End Of Test GEP General Engine Products HMMWV High...Vehicle ( BFV ), is a 14.8 liter, V8, turbocharged after-cooled diesel engine, producing approximately 600 hp, and 1225 lb-ft of torque at their respective

  10. The Fock-Schwinger gauge in the BFV formalism

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barcelos-Neto, J.; Galvao, C.A.P.; Gaete, P.

    1991-06-07

    The authors consider the implementation of a properly modified form of the Fock-Schwinger gauge condition in a general non-Abelian gauge theory in the context of the BFV formalism. In this paper arguments are presented to justify the necessity of modifying the original Fock-Schwinger condition. The free field propagator and the general Ward identity are also calculated.

  11. The effect of riboflavin and ultraviolet light on the infectivity of arboviruses.

    PubMed

    Faddy, Helen M; Prow, Natalie A; Fryk, Jesse J; Hall, Roy A; Keil, Shawn D; Goodrich, Raymond P; Marks, Denese C

    2015-04-01

    Arboviruses are an emerging threat to transfusion safety and rates of infection are likely to increase with the increased rainfall associated with climate change. Arboviral infections are common in Australia, where Ross River virus (RRV), Barmah Forest virus (BFV), and Murray Valley encephalitis virus (MVEV), among others, have the potential to cause disease in humans. The use of pathogen reduction technology (PRT) may be an alternative approach for blood services to manage the risk of arboviral transfusion transmission. In this study, the effectiveness of the Mirasol PRT (Terumo BCT) system at inactivating RRV, BFV, and MVEV in buffy coat (BC)-derived platelets (PLTs) was investigated. BC-derived PLT concentrates in additive solution (SSP+) were spiked with RRV, BFV, or MVEV and then treated with the Mirasol PRT system. The level of infectious virus was determined before and after treatment, and the reduction in viral infectivity was calculated. Treatment with PRT (Mirasol) reduced the amount of infectious virus of all three arboviruses. The greatest level of inactivation was observed for RRV (2.33 log; 99.25%), followed by BFV (1.97 log; 98.68%) and then MVEV (1.83 log; 98.42%). Our study demonstrates that treatment of PLT concentrates with PRT (Mirasol) reduces the infectious levels of RRV, BFV, and MVEV. The relevance of the level of reduction required to prevent disease transmission by transfusion has not been fully defined and requires further investigation. In the face of a changing climate, with its associated threat to blood safety, PRT represents a proactive approach for maintaining blood safety. © 2014 AABB.

  12. Hamiltonian methods: BRST, BFV

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garcia, J. Antonio

    2006-09-25

    The range of applicability of Hamiltonian methods to gauge theories is very diverse and cover areas of research from phenomenology to mathematical physics. We review some of the areas developed in Mexico in the last decades. They cover the study of symplectic methods, BRST-BFV and BV approaches, Klauder projector program, and non perturbative technics used in the study of bound states in relativistic field theories.

  13. Hamiltonian methods: BRST, BFV

    NASA Astrophysics Data System (ADS)

    García, J. Antonio

    2006-09-01

    The range of applicability of Hamiltonian methods to gauge theories is very diverse and cover areas of research from phenomenology to mathematical physics. We review some of the areas developed in México in the last decades. They cover the study of symplectic methods, BRST-BFV and BV approaches, Klauder projector program, and non perturbative technics used in the study of bound states in relativistic field theories.

  14. The Ostrogradsky Prescription for BFV Formalism

    NASA Astrophysics Data System (ADS)

    Nirov, Khazret S.

    Gauge-invariant systems of a general form with higher order time derivatives of gauge parameters are investigated within the framework of the BFV formalism. Higher order terms of the BRST charge and BRST-invariant Hamiltonian are obtained. It is shown that the identification rules for Lagrangian and Hamiltonian BRST ghost variables depend on the choice of the extension of constraints from the primary constraint surface.

  15. Hamiltonian vs Lagrangian Embedding of a Massive Spin-One Theory Involving Two-Form Field

    NASA Astrophysics Data System (ADS)

    Harikumar, E.; Sivakumar, M.

    We consider the Hamiltonian and Lagrangian embedding of a first-order, massive spin-one, gauge noninvariant theory involving antisymmetric tensor field. We apply the BFV-BRST generalized canonical approach to convert the model to a first class system and construct nilpotent BFV-BRST charge and a unitarizing Hamiltonian. The canonical analysis of the Stückelberg formulation of this model is presented. We bring out the contrasting feature in the constraint structure, specifically with respect to the reducibility aspect, of the Hamiltonian and the Lagrangian embedded model. We show that to obtain manifestly covariant Stückelberg Lagrangian from the BFV embedded Hamiltonian, phase space has to be further enlarged and show how the reducible gauge structure emerges in the embedded model.

  16. BFV quantization on hermitian symmetric spaces

    NASA Astrophysics Data System (ADS)

    Fradkin, E. S.; Linetsky, V. Ya.

    1995-02-01

    Gauge-invariant BFV approach to geometric quantization is applied to the case of hermitian symmetric spaces G/ H. In particular, gauge invariant quantization on the Lobachevski plane and sphere is carried out. Due to the presence of symmetry, master equations for the first-class constraints, quantum observables and physical quantum states are exactly solvable. BFV-BRST operator defines a flat G-connection in the Fock bundle over G/ H. Physical quantum states are covariantly constant sections with respect to this connection and are shown to coincide with the generalized coherent states for the group G. Vacuum expectation values of the quantum observables commuting with the quantum first-class constraints reduce to the covariant symbols of Berezin. The gauge-invariant approach to quantization on symplectic manifolds synthesizes geometric, deformation and Berezin quantization approaches.

  17. A comparative analysis of three vector-borne diseases across Australia using seasonal and meteorological models

    PubMed Central

    Stratton, Margaret D.; Ehrlich, Hanna Y.; Mor, Siobhan M.; Naumova, Elena N.

    2017-01-01

    Ross River virus (RRV), Barmah Forest virus (BFV), and dengue are three common mosquito-borne diseases in Australia that display notable seasonal patterns. Although all three diseases have been modeled on localized scales, no previous study has used harmonic models to compare seasonality of mosquito-borne diseases on a continent-wide scale. We fit Poisson harmonic regression models to surveillance data on RRV, BFV, and dengue (from 1993, 1995 and 1991, respectively, through 2015) incorporating seasonal, trend, and climate (temperature and rainfall) parameters. The models captured an average of 50–65% variability of the data. Disease incidence for all three diseases generally peaked in January or February, but peak timing was most variable for dengue. The most significant predictor parameters were trend and inter-annual periodicity for BFV, intra-annual periodicity for RRV, and trend for dengue. We found that a Temperature Suitability Index (TSI), designed to reclassify climate data relative to optimal conditions for vector establishment, could be applied to this context. Finally, we extrapolated our models to estimate the impact of a false-positive BFV epidemic in 2013. Creating these models and comparing variations in periodicities may provide insight into historical outbreaks as well as future patterns of mosquito-borne diseases. PMID:28071683

  18. A comparative analysis of three vector-borne diseases across Australia using seasonal and meteorological models.

    PubMed

    Stratton, Margaret D; Ehrlich, Hanna Y; Mor, Siobhan M; Naumova, Elena N

    2017-01-10

    Ross River virus (RRV), Barmah Forest virus (BFV), and dengue are three common mosquito-borne diseases in Australia that display notable seasonal patterns. Although all three diseases have been modeled on localized scales, no previous study has used harmonic models to compare seasonality of mosquito-borne diseases on a continent-wide scale. We fit Poisson harmonic regression models to surveillance data on RRV, BFV, and dengue (from 1993, 1995 and 1991, respectively, through 2015) incorporating seasonal, trend, and climate (temperature and rainfall) parameters. The models captured an average of 50-65% variability of the data. Disease incidence for all three diseases generally peaked in January or February, but peak timing was most variable for dengue. The most significant predictor parameters were trend and inter-annual periodicity for BFV, intra-annual periodicity for RRV, and trend for dengue. We found that a Temperature Suitability Index (TSI), designed to reclassify climate data relative to optimal conditions for vector establishment, could be applied to this context. Finally, we extrapolated our models to estimate the impact of a false-positive BFV epidemic in 2013. Creating these models and comparing variations in periodicities may provide insight into historical outbreaks as well as future patterns of mosquito-borne diseases.

  19. A comparative analysis of three vector-borne diseases across Australia using seasonal and meteorological models

    NASA Astrophysics Data System (ADS)

    Stratton, Margaret D.; Ehrlich, Hanna Y.; Mor, Siobhan M.; Naumova, Elena N.

    2017-01-01

    Ross River virus (RRV), Barmah Forest virus (BFV), and dengue are three common mosquito-borne diseases in Australia that display notable seasonal patterns. Although all three diseases have been modeled on localized scales, no previous study has used harmonic models to compare seasonality of mosquito-borne diseases on a continent-wide scale. We fit Poisson harmonic regression models to surveillance data on RRV, BFV, and dengue (from 1993, 1995 and 1991, respectively, through 2015) incorporating seasonal, trend, and climate (temperature and rainfall) parameters. The models captured an average of 50-65% variability of the data. Disease incidence for all three diseases generally peaked in January or February, but peak timing was most variable for dengue. The most significant predictor parameters were trend and inter-annual periodicity for BFV, intra-annual periodicity for RRV, and trend for dengue. We found that a Temperature Suitability Index (TSI), designed to reclassify climate data relative to optimal conditions for vector establishment, could be applied to this context. Finally, we extrapolated our models to estimate the impact of a false-positive BFV epidemic in 2013. Creating these models and comparing variations in periodicities may provide insight into historical outbreaks as well as future patterns of mosquito-borne diseases.

  20. Brst-Bfv Quantization and the Schwinger Action Principle

    NASA Astrophysics Data System (ADS)

    Garcia, J. Antonio; Vergara, J. David; Urrutia, Luis F.

    We introduce an operator version of the BRST-BFV effective action for arbitrary systems with first class constraints. Using the Schwinger action principle we calculate the propagators corresponding to: (i) the parametrized nonrelativistic free particle, (ii) the relativistic free particle and (iii) the spinning relativistic free particle. Our calculation correctly imposes the BRST invariance at the end points. The precise use of the additional boundary terms required in the description of fermionic variables is incorporated.

  1. Diagnosis of Barmah Forest Virus Infection by a Nested Real-Time SYBR Green RT-PCR Assay

    PubMed Central

    Hueston, Linda; Toi, Cheryl S.; Jeoffreys, Neisha; Sorrell, Tania; Gilbert, Gwendolyn

    2013-01-01

    Barmah Forest virus (BFV) is a mosquito borne (+) ssRNA alphavirus found only in Australia. It causes rash, myalgia and arthralgia in humans and is usually diagnosed serologically. We developed a real-time PCR assay to detect BFV in an effort to improve diagnosis early in the course of infection. The limit of detection was 16 genome equivalents with a specificity of 100%. Fifty five serum samples from BFV-infected patients were tested by the PCR. 52 of 53 antibody-positive samples were PCR negative. Two culture-positive (neutralizing antibody negative) samples were positive on first round PCR, while one sample (IgM and neutralizing antibody strongly positive, IgG negative) was positive on second round PCR, suggesting that viral RNA is detectable and transiently present in early infection. PCR can provide results faster than culture, is capable of high throughput and by sequencing the PCR product strain variants can be characterized. PMID:23935816

  2. Weinberg propagator of a free massive particle with an arbitrary spin from the BFV-BRST path integral

    NASA Astrophysics Data System (ADS)

    Zima, V. G.; Fedoruk, S. O.

    1999-11-01

    The transition amplitude is obtained for a free massive particle of arbitrary spin by calculating the path integral in the index-spinor formulation within the BFV-BRST approach. No renormalizations of the path integral measure were applied. The calculation has given the Weinberg propagator written in the index-free form by the use of an index spinor. The choice of boundary conditions on the index spinor determines the holomorphic or antiholomorphic representation for the canonical description of particle/antiparticle spin.

  3. The Challenges in Training of the Mechanized Infantry Units of the Republic of Korea Army in Transitioning from the Armored Personnel Carrier (K200) to Infantry Fighting Vehicle (K21)

    DTIC Science & Technology

    2012-12-14

    Technology 2011). Because this paper mainly depends on the case study of the U.S. M2 BFV fielding, the author reviewed a wide variety of literature...defilade position. The dismounted element is also available for the military operations in urban terrain and forest enviroments , and providing...of the technological developments of the BFV, such as the blue force tracking system, it is still very important and requires much time- consuming

  4. Communicable Diseases Network Australia National Arbovirus and Malaria Advisory Committee annual report, 2005-06.

    PubMed

    Liu, Conan; Johansen, Cheryl; Kurucz, Nina; Whelan, Peter

    2006-01-01

    This report describes the epidemiology of mosquito-borne disease in Australia for the mosquito-borne disease season 1 July 2005 to 30 June 2006, in which the second largest number of notifications since 1995-96 was reported. Ross River virus (RRV) infections (66%), Barmah Forest virus (BFV) infections (23%) and malaria (9%) were the most common mosquito-borne diseases reported in 2005-06. National RRV notifications were the fifth largest on record. The Northern Territory had the highest rate of RRV notifications and the peak notification rate (in January 2006) was the third highest since 2000. National BFV notification rates were the highest on record. The Northern Territory also reported the highest BFV notification rate this season, peaking in February-March 2006, which was the highest reported BFV notification rate on record. BFV notification rates were significantly higher in teenagers compared to previous seasons. There were 731 notifications of malaria in 2005-06 of which none was reported as locally acquired. This was the third highest reporting period for malaria notifications since 2000. In contrast to previous years in which Plasmodium vivax was the predominant species, Plasmodium falciparum was reported as the infecting species in 45 per cent of the malaria notifications and Plasmodium vivax for 42 per cent of cases. Young adults in the 20-24 year age group had the highest number of cases and children in the 5-9 year age group accounted for 22 per cent of notifications. There were two cases of Kunjin virus (KUNV) infection and one case of Murray Valley encephalitis virus (MVEV) infection reported in 2005-06, all from Western Australia. Sentinel chicken surveillance data for flaviviruses and sentinel pig surveillance data for Japanese encephalitis virus are reported. There were 200 notifications of dengue virus (DENV) infection in 2005-06, of which 46 per cent (n = 92) was reported as having been acquired overseas. Dengue serotypes 2 and 3 were detected in two outbreaks of locally-acquired dengue in Queensland this season.

  5. BFV activates the NF-kappaB pathway through its transactivator (BTas) to enhance viral transcription

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang Jian; Tan Juan; Zhang Xihui

    2010-05-10

    Multiple families of viruses have evolved sophisticated strategies to regulate nuclear factor-kappaB (NF-kappaB) signaling, which plays a pivotal role in diverse cellular events, including virus-host interactions. In this study, we report that bovine foamy virus (BFV) is able to activate the NF-kappaB pathway through the action of its transactivator, BTas. Both cellular IKKbeta and IkappaBalpha also participate in this activation. In addition, we demonstrate that BTas induces the processing of p100, which implies that BTas can activate NF-kappaB through a noncanonical pathway as well. Co-immunoprecipitation analysis shows that BTas interacts with IKK catalytic subunits (IKKalpha and IKKbeta), which may bemore » responsible for regulation of IKK kinase activity and persistent NF-kappaB activation. Furthermore, our results indicate that the level of BTas-mediated LTR transcription correlates with the activity of cellular NF-kappaB. Together, this study suggests that BFV activates the NF-kappaB pathway through BTas to enhance viral transcription.« less

  6. BFV activates the NF-kappaB pathway through its transactivator (BTas) to enhance viral transcription.

    PubMed

    Wang, Jian; Tan, Juan; Zhang, Xihui; Guo, Hongyan; Zhang, Qicheng; Guo, Tingting; Geng, Yunqi; Qiao, Wentao

    2010-05-10

    Multiple families of viruses have evolved sophisticated strategies to regulate nuclear factor-kappaB (NF-kappaB) signaling, which plays a pivotal role in diverse cellular events, including virus-host interactions. In this study, we report that bovine foamy virus (BFV) is able to activate the NF-kappaB pathway through the action of its transactivator, BTas. Both cellular IKKbeta and IkappaBalpha also participate in this activation. In addition, we demonstrate that BTas induces the processing of p100, which implies that BTas can activate NF-kappaB through a noncanonical pathway as well. Co-immunoprecipitation analysis shows that BTas interacts with IKK catalytic subunits (IKKalpha and IKKbeta), which may be responsible for regulation of IKK kinase activity and persistent NF-kappaB activation. Furthermore, our results indicate that the level of BTas-mediated LTR transcription correlates with the activity of cellular NF-kappaB. Together, this study suggests that BFV activates the NF-kappaB pathway through BTas to enhance viral transcription. Copyright 2010 Elsevier Inc. All rights reserved.

  7. Covariant scalar representation of ? and quantization of the scalar relativistic particle

    NASA Astrophysics Data System (ADS)

    Jarvis, P. D.; Tsohantjis, I.

    1996-03-01

    A covariant scalar representation of iosp(d,2/2) is constructed and analysed in comparison with existing BFV-BRST methods for the quantization of the scalar relativistic particle. It is found that, with appropriately defined wavefunctions, this iosp(d,2/2) produced representation can be identified with the state space arising from the canonical BFV-BRST quantization of the modular-invariant, unoriented scalar particle (or antiparticle) with admissible gauge-fixing conditions. For this model, the cohomological determination of physical states can thus be obtained purely from the representation theory of the iosp(d,2/2) algebra.

  8. Identifying spatially similar gene expression patterns in early stage fruit fly embryo images: binary feature versus invariant moment digital representations

    PubMed Central

    Gurunathan, Rajalakshmi; Van Emden, Bernard; Panchanathan, Sethuraman; Kumar, Sudhir

    2004-01-01

    Background Modern developmental biology relies heavily on the analysis of embryonic gene expression patterns. Investigators manually inspect hundreds or thousands of expression patterns to identify those that are spatially similar and to ultimately infer potential gene interactions. However, the rapid accumulation of gene expression pattern data over the last two decades, facilitated by high-throughput techniques, has produced a need for the development of efficient approaches for direct comparison of images, rather than their textual descriptions, to identify spatially similar expression patterns. Results The effectiveness of the Binary Feature Vector (BFV) and Invariant Moment Vector (IMV) based digital representations of the gene expression patterns in finding biologically meaningful patterns was compared for a small (226 images) and a large (1819 images) dataset. For each dataset, an ordered list of images, with respect to a query image, was generated to identify overlapping and similar gene expression patterns, in a manner comparable to what a developmental biologist might do. The results showed that the BFV representation consistently outperforms the IMV representation in finding biologically meaningful matches when spatial overlap of the gene expression pattern and the genes involved are considered. Furthermore, we explored the value of conducting image-content based searches in a dataset where individual expression components (or domains) of multi-domain expression patterns were also included separately. We found that this technique improves performance of both IMV and BFV based searches. Conclusions We conclude that the BFV representation consistently produces a more extensive and better list of biologically useful patterns than the IMV representation. The high quality of results obtained scales well as the search database becomes larger, which encourages efforts to build automated image query and retrieval systems for spatial gene expression patterns. PMID:15603586

  9. Bv and Bfv Formulation of a Gauge Theory of Quadratic Lie Algebras in 2d and a Construction of W3 Topological Gravity

    NASA Astrophysics Data System (ADS)

    Dayi, Ömer F.

    The recently proposed generalized field method for solving the master equation of Batalin and Vilkovisky is applied to a gauge theory of quadratic Lie algebras in two dimensions. The charge corresponding to BRST symmetry derived from this solution in terms of the phase space variables by using the Noether procedure, and the one found due to the BFV-method are compared and found to coincide. W3-algebra, formulated in terms of a continuous variable is exploit in the mentioned gauge theory to construct a W3 topological gravity. Moreover, its gauge fixing is briefly discussed.

  10. Towards Lagrangian formulations of mixed-symmetry higher spin fields on AdS-space within BFV-BRST formalism

    NASA Astrophysics Data System (ADS)

    Reshetnyak, A. A.

    2010-11-01

    The spectrum of superstring theory on the AdS 5 × S 5 Ramond-Ramond background in tensionless limit contains integer and half-integer higher-spin fields subject at most to two-rows Young tableaux Y( s 1, s 2). We review the details of a gauge-invariant Lagrangian description of such massive and massless higher-spin fields in anti-de-Sitter spaces with arbitrary dimensions. The procedure is based on the construction of Verma modules, its oscillator realizations and of a BFV-BRST operator for non-linear algebras encoding unitary irreducible representations of AdS group.

  11. Open Group Transformations

    NASA Astrophysics Data System (ADS)

    Batalin, Igor; Marnelius, Robert

    Open groups whose generators are in arbitrary involutions may be quantized within a ghost extended framework in terms of a nilpotent BFV-BRST charge operator. Previously we have shown that generalized quantum Maurer-Cartan equations for arbitrary open groups may be extracted from the quantum connection operators and that they also follow from a simple quantum master equation involving an extended nilpotent BFV-BRST charge and a master charge. Here we give further details of these results. In addition we establish the general structure of the solutions of the quantum master equation. We also construct an extended formulation whose properties are determined by the extended BRST charge in the master equation.

  12. Open groups of constraints. Integrating arbitrary involutions

    NASA Astrophysics Data System (ADS)

    Batalin, Igor; Marnelius, Robert

    1998-11-01

    A new type of quantum master equation is presented which is expressed in terms of a recently introduced quantum antibracket. The equation involves only two operators: an extended nilpotent BFV-BRST charge and an extended ghost charge. It is proposed to determine the generalized quantum Maurer-Cartan equations for arbitrary open groups. These groups are the integration of constraints in arbitrary involutions. The only condition for this is that the constraint operators may be embedded in an odd nilpotent operator, the BFV-BRST charge. The proposal is verified at the quasigroup level. The integration formulas are also used to construct a generating operator for quantum antibrackets of operators in arbitrary involutions.

  13. Case study of a central-station grid-intertie photovoltaic system with V-trough concentration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Freilich, J.; Gordon, J.M.

    1991-01-01

    This presentation is a cast study of an installed, central-station (no storage), utility-intertie photovoltaic (PV) system in Sede Boqer, Israel (latitude 30.9{degree}N). The nominally 12 kW peak PV system is comprised of 189 polycrystalline silicon modules mounted on inexpensive, one-axis north-south horizontal trackers with V-trough mirrors for optical boost. The power conditioning unit operates at a fixed voltage rather than at maximum power point (MPP). The primary task in analyzing the installed system was to investigate the cause of measured power output significantly below the design predictions of the installers, and to recommend system design modifications. Subsequent tasks included themore » quantitative assessment of fixed-voltage operation and of the energetic value of V-trough concentration and one-axis tracking for this system. Sample results show: (1) fixed-voltage operation at the best fixed voltage (BFV) can achieve around 96% of the yearly energy of MPP operation; (2) the sensitivity of the yearly energy delivery to the selection of fixed voltage and its marked asymmetry about the BFV; (3) the influences of inverter current constraints on yearly energy delivery and BFV; and (4) how the separate effects of tracking and optical concentration increase yearly energy delivery.« less

  14. The Nucleotide Sequence and Spliced pol mRNA Levels of the Nonprimate Spumavirus Bovine Foamy Virus

    PubMed Central

    Holzschu, Donald L.; Delaney, Mari A.; Renshaw, Randall W.; Casey, James W.

    1998-01-01

    We have determined the complete nucleotide sequence of a replication-competent clone of bovine foamy virus (BFV) and have quantitated the amount of splice pol mRNA processed early in infection. The 544-amino-acid Gag protein precursor has little sequence similarity with its primate foamy virus homologs, but the putative nucleocapsid (NC) protein, like the primate NCs, contains the three glycine-arginine-rich regions that are postulated to bind genomic RNA during virion assembly. The BFV gag and pol open reading frames overlap, with pro and pol in the same translational frame. As with the human foamy virus (HFV) and feline foamy virus, we have detected a spliced pol mRNA by PCR. Quantitatively, this mRNA approximates the level of full-length genomic RNA early in infection. The integrase (IN) domain of reverse transcriptase does not contain the canonical HH-CC zinc finger motif present in all characterized retroviral INs, but it does contain a nearby histidine residue that could conceivably participate as a member of the zinc finger. The env gene encodes a protein that is over 40% identical in sequence to the HFV Env. By comparison, the Gag precursor of BFV is predicted to be only 28% identical to the HFV protein. PMID:9499074

  15. The effect of bovine BST2A1 on the release and cell-to-cell transmission of retroviruses.

    PubMed

    Liang, Zhibin; Zhang, Yang; Song, Jie; Zhang, Hui; Zhang, Suzhen; Li, Yue; Tan, Juan; Qiao, Wentao

    2017-09-06

    Human BST2 (hBST2, also called Tetherin) is a host restriction factor that blocks the release of various enveloped viruses. BST2s from different mammals also possess antiviral activity. Bovine BST2s (bBST2s), bBST2A1 and bBST2A2, reduce production of cell-free bovine leukemia virus (BLV) and vesicular stomatitis virus (VSV). However, the effect of bBST2 on other retroviruses remains unstudied. Here, we studied the antiviral activity of wildtype and mutant bBST2A1 proteins on retroviruses including human immunodeficiency virus type 1 (HIV-1), prototypic foamy virus (PFV), bovine foamy virus (BFV) and bovine immunodeficiency virus (BIV). The results showed that wildtype bBST2A1 suppressed the release of HIV-1, PFV and BFV. We also generated bBST2A1 mutants, and found that GPI anchor and dimerization, but not glycosylation, are essential for antiviral activity of bBST2A1. Moreover, unlike hBST2, bBST2A1 displayed no inhibitory effect on cell-to-cell transmission of PFV, BFV and BIV. Our data suggested that bBST2A1 inhibited retrovirus release, however, had no effect on cell-to-cell transmission of retroviruses.

  16. Effects of ion doping at different sites on electrical properties of multiferroic BiFeO3 ceramics

    NASA Astrophysics Data System (ADS)

    Yu, Benfang; Li, Meiya; Liu, Jun; Guo, Dongyun; Pei, Ling; Zhao, Xingzhong

    2008-03-01

    Pure, La3+ doped at A site, V5+ doped at B site, and La3+ and V5+ co-doped multiferroic BiFeO3 ceramics: BiFeO3 (BFO), Bi0.85La0.15FeO3 (BLF), BiFe0.97V0.03O3 (BFV), Bi0.85La0.15Fe0.97V0.03O3 (BLFV), etc were successfully prepared by a rapid liquid sintering technique. X-ray diffraction indicated that these ceramics were of polycrystalline perovskite structures, accompanied with a tiny residual Bi2O3 phase. It was found that, among these ceramics, BLFV ceramic exhibited the best electrical properties. The leakage current density of BLFV ceramic was only 2.1 × 10-6 A cm-2 at 10 kV cm-1, two and one orders of magnitude lower than those of the BLF and BFV ceramics, respectively. In the measuring frequency of 4 KHz-1 MHz, the dielectric constants and losses of this sample exhibited slight variation and the lowest loss tangent was 0.08. The sample had a relatively saturated ferroelectric hysteresis loop. These suggested that the co-doped BiFeO3 ceramic by La3+ and V5+ at A and B sites showed advantages in application over the pure BFO, doped BLF and BFV ceramics, respectively.

  17. BRST technique for the cosmological density matrix

    NASA Astrophysics Data System (ADS)

    Barvinsky, A. O.

    2013-10-01

    The microcanonical density matrix in closed cosmology has a natural definition as a projector on the space of solutions of Wheeler-DeWitt equations, which is motivated by the absence of global non-vanishing charges and energy in spatially closed gravitational systems. Using the BRST/BFV formalism in relativistic phase space of gauge and ghost variables we derive the path integral representation for this projector and the relevant statistical sum. This derivation circumvents the difficulties associated with the open algebra of noncommutative quantum Dirac constraints and the construction/regularization of the physical inner product in the subspace of BRS singlets. This inner product is achieved via the Batalin-Marnelius gauge fixing in the space of BRS-invariant states, which in its turn is shown to be a result of truncation of the BRST/BFV formalism to the "matter" sector of relativistic phase space.

  18. On the Perturbative Equivalence Between the Hamiltonian and Lagrangian Quantizations

    NASA Astrophysics Data System (ADS)

    Batalin, I. A.; Tyutin, I. V.

    The Hamiltonian (BFV) and Lagrangian (BV) quantization schemes are proved to be perturbatively equivalent to each other. It is shown in particular that the quantum master equation being treated perturbatively possesses a local formal solution.

  19. An operator approach to BRST invariant transition amplitudes

    NASA Astrophysics Data System (ADS)

    Rabello, Silvio J.; Vaidya, Arvind N.

    1994-10-01

    The transition amplitudes for the free spinless and spinning relativistic particles are obtained by applying an operator method developed long ago by Dirac and Schwinger to the BFV form of the BRST theory for constrained systems.

  20. Perturbative Quantum Gauge Theories on Manifolds with Boundary

    NASA Astrophysics Data System (ADS)

    Cattaneo, Alberto S.; Mnev, Pavel; Reshetikhin, Nicolai

    2018-01-01

    This paper introduces a general perturbative quantization scheme for gauge theories on manifolds with boundary, compatible with cutting and gluing, in the cohomological symplectic (BV-BFV) formalism. Explicit examples, like abelian BF theory and its perturbations, including nontopological ones, are presented.

  1. On Time

    NASA Astrophysics Data System (ADS)

    Cattaneo, Alberto S.; Schiavina, Michele

    2017-02-01

    This note describes the restoration of time in one-dimensional parameterization-invariant (hence timeless) models, namely, the classically equivalent Jacobi action and gravity coupled to matter. It also serves as a timely introduction by examples to the classical and quantum BV-BFV formalism as well as to the AKSZ method.

  2. Dimerization of BTas is required for the transactivational activity of bovine foamy virus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tan Juan; Qiao Wentao; Xu Fengwen

    2008-06-20

    The BTas protein of bovine foamy virus (BFV) is a 249-amino-acid nuclear regulatory protein which transactivates viral gene expression directed by the long terminal repeat promoter (LTR) and the internal promoter (IP). Here, we demonstrate the BTas protein forms a dimeric complex in mammalian cells by using mammalian two hybrid systems and cross-linking assay. Functional analyses with deletion mutants reveal that the region of 46-62aa is essential for dimer formation. Furthermore, our results show that deleting the dimerization region of BTas did not affect the localization of BTas, but that it did result in the loss of its transactivational activitymore » on the LTR and IP. Furthermore, BTas ({delta}46-62aa) retained binding ability to the LTR and IP similar to that of the wild-type BTas. These data suggest the dimerization region is necessary for the transactivational function of BTas and is crucial to the replication of BFV.« less

  3. Symplectic Quantization of a Reducible Theory

    NASA Astrophysics Data System (ADS)

    Barcelos-Neto, J.; Silva, M. B. D.

    We use the symplectic formalism to quantize the Abelian antisymmetric tensor gauge field. It is related to a reducible theory in the sense that all of its constraints are not independent. A procedure like ghost-of-ghost of the BFV method has to be used, but in terms of Lagrange multipliers.

  4. IFP35 Is Involved in the Antiviral Function of Interferon by Association with the Viral Tas Transactivator of Bovine Foamy Virus▿

    PubMed Central

    Tan, Juan; Qiao, Wentao; Wang, Jian; Xu, Fengwen; Li, Yue; Zhou, Jun; Chen, Qimin; Geng, Yunqi

    2008-01-01

    Interferon-induced proteins (IFPs) exert multiple functions corresponding to diverse interferon signals. However, the intracellular functions of many IFPs are not fully characterized. Here, we report that IFP35, a member of the IFP family with a molecular mass of 35 kDa, can interact with the bovine Tas (BTas) regulatory protein of bovine foamy virus (BFV). The interaction involves NID2 (IFP35/Nmi homology domain) of IFP35 and the central domain of BTas. The overexpression of IFP35 disturbs the ability of BTas to activate viral-gene transcription and inhibits viral replication. The depletion of endogenous IFP35 by interfering RNA can promote the activation of BFV, suggesting an inhibitory function of IFP35 in viral-gene expression. In addition, IFP35 can interact with the homologous regulatory protein of prototype FV and arrest viral replication and repress viral transcription. Our study suggests that IFP35 may represent a novel pathway of interferon-mediated antiviral activity in host organisms that plays a role in the maintenance of FV latency. PMID:18305040

  5. BFV-BRST quantization of two-dimensional supergravity

    NASA Astrophysics Data System (ADS)

    Fujiwara, T.; Igarashi, Y.; Kuriki, R.; Tabei, T.

    1996-01-01

    Two-dimensional supergravity theory is quantized as an anomalous gauge theory. In the Batalin-Fradkin (BF) formalism, the anomaly-canceling super-Liouville fields are introduced to identify the original second-class constrained system with a gauge-fixed version of a first-class system. The BFV-BRST quantization applies to formulate the theory in the most general class of gauges. A local effective action constructed in the configuration space contains two super-Liouville actions; one is a noncovariant but local functional written only in terms of two-dimensional supergravity fields, and the other contains the super-Liouville fields canceling the super-Weyl anomaly. Auxiliary fields for the Liouville and the gravity supermultiplets are introduced to make the BRST algebra close off-shell. Inclusion of them turns out to be essentially important especially in the super-light-cone gauge fixing, where the supercurvature equations (∂3-g++=∂2-χ++=0) are obtained as a result of BRST invariance of the theory. Our approach reveals the origin of the OSp(1,2) current algebra symmetry in a transparent manner.

  6. BRST Quantization of the Proca Model Based on the BFT and the BFV Formalism

    NASA Astrophysics Data System (ADS)

    Kim, Yong-Wan; Park, Mu-In; Park, Young-Jai; Yoon, Sean J.

    The BRST quantization of the Abelian Proca model is performed using the Batalin-Fradkin-Tyutin and the Batalin-Fradkin-Vilkovisky formalism. First, the BFT Hamiltonian method is applied in order to systematically convert a second class constraint system of the model into an effectively first class one by introducing new fields. In finding the involutive Hamiltonian we adopt a new approach which is simpler than the usual one. We also show that in our model the Dirac brackets of the phase space variables in the original second class constraint system are exactly the same as the Poisson brackets of the corresponding modified fields in the extended phase space due to the linear character of the constraints comparing the Dirac or Faddeev-Jackiw formalisms. Then, according to the BFV formalism we obtain that the desired resulting Lagrangian preserving BRST symmetry in the standard local gauge fixing procedure naturally includes the Stückelberg scalar related to the explicit gauge symmetry breaking effect due to the presence of the mass term. We also analyze the nonstandard nonlocal gauge fixing procedure.

  7. Composite structural armor for combat vehicle applications

    NASA Technical Reports Server (NTRS)

    Haskell, William E., III; Alesi, A. L.; Parsons, G. R.

    1990-01-01

    Several projects that have demonstrated the advantages of using thick composite armor technology for structural applications in armored combat vehicles are discussed. The first involved composite cargo doors for the Marine Corps LVTP-7 amphibious landing vehicle. Another was a demonstration composite turret that offered a weight reduction of 15.5 percent. The advantages of this composite armor compared to metallic armors used for combat vehicle hull and turret applications are reduced weight at equal ballistic protection; reduced back armor spall; excellent corrosion resistance; reduced production costs by parts consolidation; and inherent thermal and acoustic insulative properties. Based on the encouraging results of these past programs, the Demonstration Composite Hull Program was started in September 1986. To demonstrate this composite armor technology, the Army's newest infantry fighting vehicle, the Bradley Fighting Vehicle (BFV), was selected as a model. A composite infantry fighting vehicle, designated the CIFV for this program, has been designed and fabricated and is currently undergoing a 6000 mile field endurance test. The CIFV demonstration vehicle uses the BFV engine, transmission, suspension, track and other equipment.

  8. The Structure of Barmah Forest Virus as Revealed by Cryo-Electron Microscopy at a 6-Angstrom Resolution Has Detailed Transmembrane Protein Architecture and Interactions ▿ †

    PubMed Central

    Kostyuchenko, Victor A.; Jakana, Joanita; Liu, Xiangan; Haddow, Andrew D.; Aung, Myint; Weaver, Scott C.; Chiu, Wah; Lok, Shee-Mei

    2011-01-01

    Barmah Forest virus (BFV) is a mosquito-borne alphavirus that infects humans. A 6-Å-resolution cryo-electron microscopy three-dimensional structure of BFV exhibits a typical alphavirus organization, with RNA-containing nucleocapsid surrounded by a bilipid membrane anchored with the surface proteins E1 and E2. The map allows details of the transmembrane regions of E1 and E2 to be seen. The C-terminal end of the E2 transmembrane helix binds to the capsid protein. Following the E2 transmembrane helix, a short α-helical endodomain lies on the inner surface of the lipid envelope. The E2 endodomain interacts with E1 transmembrane helix from a neighboring E1-E2 trimeric spike, thereby acting as a spacer and a linker between spikes. In agreement with previous mutagenesis studies, the endodomain plays an important role in recruiting other E1-E2 spikes to the budding site during virus assembly. The E2 endodomain may thus serve as a target for antiviral drug design. PMID:21752915

  9. Changes of the Carotid Artery Doppler Flow Velocity Pattern after Sublingual Nitroglycerin in Patients with Hypertension

    PubMed Central

    Jeong, Jin-Won; Park, Ock-Kyu; Park, Yang-Kyu; Tei, Chuwa; Tanaka, Nobuyuki

    1998-01-01

    Objective To evaluate the applicability of carotid Doppler echography for the assessment of changes of peripheral hemodynamics in the hypertensives. Subjects 28 hypertensives (17 males, 11 females), mean age of 64 yrs and 40 normal controls (24 males, 16 females) mean age of 49 yrs. Methods We recorded the right common carotid arterial Doppler flow velocity (BFV) pattern and measured the peak velocities of the percussion wave (P) and late rising tidal wave (T), the ratio of the two (P/T), the time interval between the two peaks corrected by heart rate (P-Tc), systolic flow velocity integral (FVI) and carotid artery diameter (CAD) before and after 0.4 mg dose of subligual nitroglycerin (NTG). Results 1) In hypertensives, the P wave velocity showed lower and P-Tc interval shorter than those of the normal controls at baseline. 2) After NTG, the P-Tc and P/T increased, but the T and FVI decreased significantly in both groups of subjects. 3) The P/T ratio was less significantly increased after NTG in the hypertensives than in the controls. These results suggest that NTG might have been involved in concomitant reduction and delay of the wave reflection from the peripheral vessels, preferentially in the normal subjects than in hypertensives. Concluson The carotid Doppler echography can be useful for the evaluation of the changes of hemodynamics in the peripheral vessel such as carotid artery in hypertensive subjects. PMID:9538627

  10. Results from the Water Flow Test of the Tank 37 Backflush Valve

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fowley, M.D.

    2002-11-01

    A flow test was conducted in the Thermal Fluids Lab with the Tank 37 Backflush Valve to determine the pressure drop of water flow through the material transfer port. The flow rate was varied from 0 to 100 gpm. The pressure drop through the Backflush Valve for flow rates of 20 and 70 gpm was determined to be 0.18 and 1.77 feet of H2O, respectively. An equivalent length of the Backflush Valve was derived from the flow test data. The equivalent length was used in a head loss calculation for the Tank 37 Gravity Drain Line. The calculation estimated themore » flow rate that would fill the line up to the Separator Tank, and the additional flow rate that would fill the Separator Tank. The viscosity of the fluid used in the calculation was 12 centipoise. Two specific gravities were investigated, 1.4 and 1.8. The Gravity Drain Line was assumed to be clean, unobstructed stainless steel pipe. The flow rate that would fill the line up to the Separator Tank was 73 and 75 gpm for the 1.4 or 1.8 specific gravity fluids, respectively. The flow rate that would fill the Separator Tank was 96 and 100 gpm for the 1.4 or 1.8 specific gravity fluids, respectively. These results indicate that concentrate will not back up into the Separator Tank during evaporator normal operation, 15-25 gpm, or pot liftout, 70 gpm. A noteworthy observation during the flow test was water pouring from the holes in the catheterization tube. Water poured from the holes at 25 gpm and above. Data from the water flow test indicates that at 25 gpm the pressure drop through the Backflush Valve is 0.26 ft of H2O. A concentrate with a specific gravity of 1.8 and a viscosity of 12 cp will produce the same pressure drop at 20 gpm. This implies that concentrate from the evaporator may spill out into the BFV riser during a transfer.« less

  11. Equivariance, BRST symmetry, and superspace

    NASA Astrophysics Data System (ADS)

    Niemi, Antti J.; Tirkkonen, Olav

    1994-12-01

    The structure of equivariant cohomology in non-Abelian localization formulas and topological field theories is discussed. Equivariance is formulated in terms of a nilpotent Becchi-Rouet-Stora-Tyutin (BRST) symmetry, and another nilpotent operator which restricts the BRST cohomology onto the equivariant, or basic sector. A superfield formulation is presented and connections to reducible [Batalin-Fradkin-Vilkovisky (BFV)] quantization of topological Yang-Mills theory are discussed.

  12. BFV-BRST quantization of two-dimensional supergravity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fujiwara, T.; Igarashi, Y.; Kuriki, R.

    1996-01-01

    Two-dimensional supergravity theory is quantized as an anomalous gauge theory. In the Batalin-Fradkin (BF) formalism, the anomaly-canceling super-Liouville fields are introduced to identify the original second-class constrained system with a gauge-fixed version of a first-class system. The BFV-BRST quantization applies to formulate the theory in the most general class of gauges. A local effective action constructed in the configuration space contains two super-Liouville actions; one is a noncovariant but local functional written only in terms of two-dimensional supergravity fields, and the other contains the super-Liouville fields canceling the super-Weyl anomaly. Auxiliary fields for the Liouville and the gravity supermultiplets aremore » introduced to make the BRST algebra close off-shell. Inclusion of them turns out to be essentially important especially in the super-light-cone gauge fixing, where the supercurvature equations ({partial_derivative}{sup 3}{sub {minus}}{ital g}{sub +}{sub +}={partial_derivative}{sup 2}{sub {minus}}{chi}{sub +}{sub +}=0) are obtained as a result of BRST invariance of the theory. Our approach reveals the origin of the OSp(1,2) current algebra symmetry in a transparent manner. {copyright} {ital 1996 The American Physical Society.}« less

  13. Evaluation of cerebral vasomotor reactivity in Parkinson's disease: is there any association with orthostatic hypotension?

    PubMed

    Zamani, Babak; Mehrabani, Mehrnoush; Fereshtehnejad, Seyed-Mohammad; Rohani, Mohammad

    2011-06-01

    Our aim was to look for a probable relationship between cerebral vasomotor reactivity (VMR) and orthostatic hypotension (OH) in Parkinson's disease (PD). This study was conducted on 44 patients with PD. Assessment of cerebral VMR was performed by means of transcranial Doppler (TCD) of middle cerebral artery (MCA) before and after a vasodilatory stimulus, carbon dioxide test. Moreover, orthostatic hypotension was evaluated. OH was presented in 12 (27.3%) Parkinson's patients. The average resting blood flow velocity (BFV) in the MCA was 30.20 (SD=9.58)cms(-1) which significantly increased to 46.25 (SD=16.23)cms(-1) after carbon dioxide test (P<0.001). Impaired VMR was observed in 15 (34.1%) of the subjects, while it was not associated with the presence of OH (P=0.770). Evaluation of VMR in patients affected by PD, could assist in early diagnosis of cerebral autonomic dysfunction and prevent its serious consequences prior and more valid to OH. Crown Copyright © 2010. Published by Elsevier B.V. All rights reserved.

  14. General Lagrangian formulation for higher spin fields with arbitrary index symmetry. 2. Fermionic fields

    NASA Astrophysics Data System (ADS)

    Reshetnyak, A.

    2013-04-01

    We continue the construction of a Lagrangian description of irreducible half-integer higher-spin representations of the Poincare group with an arbitrary Young tableaux having k rows, on a basis of the BRST-BFV approach suggested for bosonic fields in our first article [I.L. Buchbinder, A. Reshetnyak, Nucl. Phys. B 862 (2012) 270, arXiv:1110.5044 [hep-th

  15. Explicit construction of BRST charge of noncommutative D-brane system

    NASA Astrophysics Data System (ADS)

    Hong, Soon-Tae

    2006-01-01

    In the BRST BFV scheme for noncommutative D-branes with constant NS B-field, introducing ghost degrees of freedom we construct the gauge-fixed Hamiltonian and corresponding effective Lagrangian invariant under nilpotent BRST charge. It is also shown that the presence of auxiliary variables introduced via the improved Dirac formalism plays a crucial role in the construction of the BRST invariant Lagrangian.

  16. Symplectic Quantization of a Vector-Tensor Gauge Theory with Topological Coupling

    NASA Astrophysics Data System (ADS)

    Barcelos-Neto, J.; Silva, M. B. D.

    We use the symplectic formalism to quantize a gauge theory where vectors and tensors fields are coupled in a topological way. This is an example of reducible theory and a procedure like of ghosts-of-ghosts of the BFV method is applied but in terms of Lagrange multipliers. Our final results are in agreement with the ones found in the literature by using the Dirac method.

  17. BRST Formalism for Systems with Higher Order Derivatives of Gauge Parameters

    NASA Astrophysics Data System (ADS)

    Nirov, Kh. S.

    For a wide class of mechanical systems, invariant under gauge transformations with arbitrary higher order time derivatives of gauge parameters, the equivalence of Lagrangian and Hamiltonian BRST formalisms is proved. It is shown that the Ostrogradsky formalism establishes the natural rules to relate the BFV ghost canonical pairs with the ghosts and antighosts introduced by the Lagrangian approach. Explicit relation between corresponding gauge-fixing terms is obtained.

  18. Antisymplectic gauge theories

    NASA Astrophysics Data System (ADS)

    Batalin, Igor; Marnelius, Robert

    1998-02-01

    A general field-antifield BV formalism for antisymplectic first class constraints is proposed. It is as general as the corresponding symplectic BFV-BRST formulation and it is demonstrated to be consistent with a previously proposed formalism for antisymplectic second class constraints through a generalized conversion to corresponding first class constraints. Thereby the basic concept of gauge symmetry is extended to apply to quite a new class of gauge theories potentially possible to exist.

  19. Fedosov Deformation Quantization as a BRST Theory

    NASA Astrophysics Data System (ADS)

    Grigoriev, M. A.; Lyakhovich, S. L.

    The relationship is established between the Fedosov deformation quantization of a general symplectic manifold and the BFV-BRST quantization of constrained dynamical systems. The original symplectic manifold M is presented as a second class constrained surface in the fibre bundle ?*ρM which is a certain modification of a usual cotangent bundle equipped with a natural symplectic structure. The second class system is converted into the first class one by continuation of the constraints into the extended manifold, being a direct sum of ?*ρM and the tangent bundle TM. This extended manifold is equipped with a nontrivial Poisson bracket which naturally involves two basic ingredients of Fedosov geometry: the symplectic structure and the symplectic connection. The constructed first class constrained theory, being equivalent to the original symplectic manifold, is quantized through the BFV-BRST procedure. The existence theorem is proven for the quantum BRST charge and the quantum BRST invariant observables. The adjoint action of the quantum BRST charge is identified with the Abelian Fedosov connection while any observable, being proven to be a unique BRST invariant continuation for the values defined in the original symplectic manifold, is identified with the Fedosov flat section of the Weyl bundle. The Fedosov fibrewise star multiplication is thus recognized as a conventional product of the quantum BRST invariant observables.

  20. Internal jugular and vertebral vein volume flow in patients with clinically isolated syndrome or mild multiple sclerosis and healthy controls: results from a prospective sonographer-blinded study.

    PubMed

    Chambers, Brian; Chambers, Jayne; Churilov, Leonid; Cameron, Heather; Macdonell, Richard

    2014-09-01

    We evaluated internal jugular vein and vertebral vein volume flow using ultrasound, in patients with clinically isolated syndrome or mild multiple sclerosis and controls, to determine whether volume flow was different between the two groups. In patients and controls, internal jugular vein volume flow increased from superior to inferior segments, consistent with recruitment from collateral veins. Internal jugular vein and vertebral vein volume flow were greater on the right in supine and sitting positions. Internal jugular vein volume flow was higher in the supine posture. Vertebral vein volume flow was higher in the sitting posture. Regression analyses of cube root transformed volume flow data, adjusted for supine/sitting, right/left and internal jugular vein/vertebral vein, revealed no significant difference in volume flow in patients compared to controls. Our findings further refute the concept of venous obstruction as a causal factor in the pathogenesis of multiple sclerosis. Control volume flow data may provide useful normative reference values. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  1. The Casalbuoni-Brink-Schwarz superparticle with covariant, reducible constraints

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dayi, O.F.

    1992-04-30

    This paper discusses the fermionic constraints of the massless Casalbuoni-Brink-Schwarz superparticle in d = 10 which are separated covariantly as first- and second-class constraints which are infinitely reducible. Although the reducibility conditions of the second-class constraints include the first-class ones a consistent quantization is possible. The ghost structure of the system for quantizing it in terms of the BFV-BRST methods is given and unitarity is shown.

  2. Superfield Hamiltonian quantization in terms of quantum antibrackets

    NASA Astrophysics Data System (ADS)

    Batalin, Igor A.; Lavrov, Peter M.

    2016-04-01

    We develop a new version of the superfield Hamiltonian quantization. The main new feature is that the BRST-BFV charge and the gauge fixing Fermion are introduced on equal footing within the sigma model approach, which provides for the actual use of the quantum/derived antibrackets. We study in detail the generating equations for the quantum antibrackets and their primed counterparts. We discuss the finite quantum anticanonical transformations generated by the quantum antibracket.

  3. AKSZ construction from reduction data

    NASA Astrophysics Data System (ADS)

    Bonechi, Francesco; Cabrera, Alejandro; Zabzine, Maxim

    2012-07-01

    We discuss a general procedure to encode the reduction of the target space geometry into AKSZ sigma models. This is done by considering the AKSZ construction with target the BFV model for constrained graded symplectic manifolds. We investigate the relation between this sigma model and the one with the reduced structure. We also discuss several examples in dimension two and three when the symmetries come from Lie group actions and systematically recover models already proposed in the literature.

  4. The Accuracy and Precision of Flow Measurements Using Phase Contrast Techniques

    NASA Astrophysics Data System (ADS)

    Tang, Chao

    Quantitative volume flow rate measurements using the magnetic resonance imaging technique are studied in this dissertation because the volume flow rates have a special interest in the blood supply of the human body. The method of quantitative volume flow rate measurements is based on the phase contrast technique, which assumes a linear relationship between the phase and flow velocity of spins. By measuring the phase shift of nuclear spins and integrating velocity across the lumen of the vessel, we can determine the volume flow rate. The accuracy and precision of volume flow rate measurements obtained using the phase contrast technique are studied by computer simulations and experiments. The various factors studied include (1) the partial volume effect due to voxel dimensions and slice thickness relative to the vessel dimensions; (2) vessel angulation relative to the imaging plane; (3) intravoxel phase dispersion; (4) flow velocity relative to the magnitude of the flow encoding gradient. The partial volume effect is demonstrated to be the major obstacle to obtaining accurate flow measurements for both laminar and plug flow. Laminar flow can be measured more accurately than plug flow in the same condition. Both the experiment and simulation results for laminar flow show that, to obtain the accuracy of volume flow rate measurements to within 10%, at least 16 voxels are needed to cover the vessel lumen. The accuracy of flow measurements depends strongly on the relative intensity of signal from stationary tissues. A correction method is proposed to compensate for the partial volume effect. The correction method is based on a small phase shift approximation. After the correction, the errors due to the partial volume effect are compensated, allowing more accurate results to be obtained. An automatic program based on the correction method is developed and implemented on a Sun workstation. The correction method is applied to the simulation and experiment results. The results show that the correction significantly reduces the errors due to the partial volume effect. We apply the correction method to the data of in vivo studies. Because the blood flow is not known, the results of correction are tested according to the common knowledge (such as cardiac output) and conservation of flow. For example, the volume of blood flowing to the brain should be equal to the volume of blood flowing from the brain. Our measurement results are very convincing.

  5. 21 CFR 876.1800 - Urine flow or volume measuring system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... volume measuring system. (a) Identification. A urine flow or volume measuring system is a device that measures directly or indirectly the volume or flow of urine from a patient, either during the course of... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Urine flow or volume measuring system. 876.1800...

  6. Flow and volume dependence of rat airway resistance during constant flow inflation and deflation.

    PubMed

    Rubini, Alessandro; Carniel, Emanuele Luigi; Parmagnani, Andrea; Natali, Arturo Nicola

    2011-12-01

    The aim of this study was to measure the flow and volume dependence of both the ohmic and the viscoelastic pressure dissipations of the normal rat respiratory system separately during inflation and deflation. The study was conducted in the Respiratory Physiology Laboratory in our institution. Measurements were obtained for Seven albino Wistar rats of both sexes by using the flow interruption method during constant flow inflations and deflations. Measurements included anesthesia induction, tracheostomy and positioning of a tracheal cannula, positive pressure ventilation, constant flow respiratory system inflations and deflations at two different volumes and flows. The ohmic resistance exhibited volume and flow dependence, decreasing with lung volume and increasing with flow rate, during both inflation and deflation. The stress relaxation-related viscoelastic resistance also exhibited volume and flow dependence. It decreased with the flow rate at a constant lung volume during both inflation and deflation, but exhibited a different behavior with the lung volume at a constant flow rate (i.e., increased during inflations and decreased during deflations). Thus, stress relaxation in the rat lungs exhibited a hysteretic behavior. The observed flow and volume dependence of respiratory system resistance may be predicted by an equation derived from a model of the respiratory system that consists of two distinct compartments. The equation agrees well with the experimental data and indicates that the loading time is the critical parameter on which stress relaxation depends, during both lung inflation and deflation.

  7. Action principle for overdetermined systems of nonlinear field equations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nissimov, E.; Pacheva, S.; Solomon, S.

    1989-01-01

    The authors propose a general scheme for constructing an action principle for arbitrary consistent overdetermined systems of nonlinear field equations. The principal tool is the BFV-BRST formalism. There is no need for star-product nor Chern-Simons forms. The main application of this general construction is the derivation of a superspace action in terms of unconstrained superfields for the D = 10N = 1 Super-Yang-Mills theory. The latter contains cubic as well as quartic interactions.

  8. Symmetries of SU(2) Skyrmion in Hamiltonian and Lagrangian Approaches

    NASA Astrophysics Data System (ADS)

    Hong, Soon-Tae; Kim, Yong-Wan; Park, Young-Jai

    We apply the Batalin-Fradkin-Tyutin (BFT) method to the SU(2) Skyrmion to study the full symmetry structure of the model at the first-class Hamiltonian level. On the other hand, we also analyze the symmetry structure of the action having the WZ term, which corresponds to this Hamiltonian, in the framework of the Lagrangian approach. Furthermore, following the BFV formalism we derive the BRST invariant gauge fixed Lagrangian from the above extended action.

  9. 21 CFR 876.1800 - Urine flow or volume measuring system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Urine flow or volume measuring system. 876.1800... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Diagnostic Devices § 876.1800 Urine flow or volume measuring system. (a) Identification. A urine flow or volume measuring system is a device that...

  10. 21 CFR 876.1800 - Urine flow or volume measuring system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Urine flow or volume measuring system. 876.1800... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Diagnostic Devices § 876.1800 Urine flow or volume measuring system. (a) Identification. A urine flow or volume measuring system is a device that...

  11. 21 CFR 876.1800 - Urine flow or volume measuring system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Urine flow or volume measuring system. 876.1800... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Diagnostic Devices § 876.1800 Urine flow or volume measuring system. (a) Identification. A urine flow or volume measuring system is a device that...

  12. 21 CFR 876.1800 - Urine flow or volume measuring system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Urine flow or volume measuring system. 876.1800... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Diagnostic Devices § 876.1800 Urine flow or volume measuring system. (a) Identification. A urine flow or volume measuring system is a device that...

  13. Weinberg propagator of a massive particle with an arbitrary spin (in Ukrainian)

    NASA Astrophysics Data System (ADS)

    Zima, V. G.; Fedoruk, S. O.

    The transition amplitude is obtained for a free massive particle of an arbitrary spin by calculating the path integral in the index--spinor formulation within the BFV--BRST approach. None renormalizations of the path integral measure were applied. The calculation has given the Weinberg propagator written in the index--free form with the use of an index spinor. The choice of boundary conditions on the index spinor determines holomorphic or antiholomorphic representation for the canonical description of particle/antiparticle spin.

  14. Superfield quantization

    NASA Astrophysics Data System (ADS)

    Batalin, I. A.; Bering, K.; Damgaard, P. H.

    1998-03-01

    We present a superfield formulation of the quantization program for theories with first-class constraints. An exact operator formulation is given, and we show how to set up a phase-space path integral entirely in terms of superfields. BRST transformations and canonical transformations enter on equal footing, and they allow us to establish a superspace analog of the BFV theorem. We also present a formal derivation of the Lagrangian superfield analogue of the field-antifield formalism by an integration over half of the phase-space variables.

  15. BRST formulation of 4-monopoles

    NASA Astrophysics Data System (ADS)

    Gianvittorio, R.; Martin, I.; Restuccia, A.

    1996-11-01

    A supersymmetric gauge-invariant action is constructed over any four-dimensional Riemannian manifold describing Witten's theory of 4-monopoles. The topological supersymmetric algebra closes off-shell. The multiplets include the auxiliary fields and the Wess - Zumino fields in an unusual way, arising naturally from BRST gauge fixing. A new canonical approach over Riemann manifolds is followed, using a Morse function as a Euclidean time and taking into account the BRST boundary conditions that come from the BFV formulation. This allows a construction of the effective action starting from gauge principles.

  16. Two-stage preconcentrator for vapor/particle detection

    DOEpatents

    Linker, Kevin L.; Brusseau, Charles A.

    2002-01-01

    A device for concentrating particles from a high volume gas stream and delivering the particles for detection in a low volume gas stream includes first and second preconcentrators. The first preconcentrator has a first structure for retaining particles in a first gas flow path through which a first gas flows at a relatively high volume, valves for selectively stopping the first gas flow; and a second gas flow path through which gas flows at an intermediate flow volume for moving particles from the first structure. The second preconcentrator includes a second structure for retaining particles in the second gas flow path; a valve for selectively stopping the second gas flow; and a third gas flow path through which gas flows at a low volume for moving particles from the second structure to a detector. Each of the particle retaining structures is preferably a metal screen that may be resistively heated by application of an electric potential to release the particles.

  17. Empirical models to predict the volumes of debris flows generated by recently burned basins in the western U.S.

    USGS Publications Warehouse

    Gartner, J.E.; Cannon, S.H.; Santi, P.M.; deWolfe, V.G.

    2008-01-01

    Recently burned basins frequently produce debris flows in response to moderate-to-severe rainfall. Post-fire hazard assessments of debris flows are most useful when they predict the volume of material that may flow out of a burned basin. This study develops a set of empirically-based models that predict potential volumes of wildfire-related debris flows in different regions and geologic settings. The models were developed using data from 53 recently burned basins in Colorado, Utah and California. The volumes of debris flows in these basins were determined by either measuring the volume of material eroded from the channels, or by estimating the amount of material removed from debris retention basins. For each basin, independent variables thought to affect the volume of the debris flow were determined. These variables include measures of basin morphology, basin areas burned at different severities, soil material properties, rock type, and rainfall amounts and intensities for storms triggering debris flows. Using these data, multiple regression analyses were used to create separate predictive models for volumes of debris flows generated by burned basins in six separate regions or settings, including the western U.S., southern California, the Rocky Mountain region, and basins underlain by sedimentary, metamorphic and granitic rocks. An evaluation of these models indicated that the best model (the Western U.S. model) explains 83% of the variability in the volumes of the debris flows, and includes variables that describe the basin area with slopes greater than or equal to 30%, the basin area burned at moderate and high severity, and total storm rainfall. This model was independently validated by comparing volumes of debris flows reported in the literature, to volumes estimated using the model. Eighty-seven percent of the reported volumes were within two residual standard errors of the volumes predicted using the model. This model is an improvement over previous models in that it includes a measure of burn severity and an estimate of modeling errors. The application of this model, in conjunction with models for the probability of debris flows, will enable more complete and rapid assessments of debris flow hazards following wildfire.

  18. Empirical model for the volume-change behavior of debris flows

    USGS Publications Warehouse

    Cannon, S.H.; ,

    1993-01-01

    The potential travel down hillsides; movement stops where the volume-change behavior of flows as they travel down hillsides ; movement stops where the volume of actively flowing debris becomes negligible. The average change in volume over distance for 26 recent debris flows in the Honolulu area was assumed to be a function of the slope over which the debris flow traveled, the degree of flow confinement by the channel, and an assigned value for the type of vegetation through which the debris flow traveled. Analysis of the data yielded a relation that can be incorporated into digital elevation models to characterize debris-flow travel on Oahu.

  19. Vector velocity volume flow estimation: Sources of error and corrections applied for arteriovenous fistulas.

    PubMed

    Jensen, Jonas; Olesen, Jacob Bjerring; Stuart, Matthias Bo; Hansen, Peter Møller; Nielsen, Michael Bachmann; Jensen, Jørgen Arendt

    2016-08-01

    A method for vector velocity volume flow estimation is presented, along with an investigation of its sources of error and correction of actual volume flow measurements. Volume flow errors are quantified theoretically by numerical modeling, through flow phantom measurements, and studied in vivo. This paper investigates errors from estimating volumetric flow using a commercial ultrasound scanner and the common assumptions made in the literature. The theoretical model shows, e.g. that volume flow is underestimated by 15%, when the scan plane is off-axis with the vessel center by 28% of the vessel radius. The error sources were also studied in vivo under realistic clinical conditions, and the theoretical results were applied for correcting the volume flow errors. Twenty dialysis patients with arteriovenous fistulas were scanned to obtain vector flow maps of fistulas. When fitting an ellipsis to cross-sectional scans of the fistulas, the major axis was on average 10.2mm, which is 8.6% larger than the minor axis. The ultrasound beam was on average 1.5mm from the vessel center, corresponding to 28% of the semi-major axis in an average fistula. Estimating volume flow with an elliptical, rather than circular, vessel area and correcting the ultrasound beam for being off-axis, gave a significant (p=0.008) reduction in error from 31.2% to 24.3%. The error is relative to the Ultrasound Dilution Technique, which is considered the gold standard for volume flow estimation for dialysis patients. The study shows the importance of correcting for volume flow errors, which are often made in clinical practice. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Determination of fractional flow reserve (FFR) based on scaling laws: a simulation study

    NASA Astrophysics Data System (ADS)

    Wong, Jerry T.; Molloi, Sabee

    2008-07-01

    Fractional flow reserve (FFR) provides an objective physiological evaluation of stenosis severity. A technique that can measure FFR using only angiographic images would be a valuable tool in the cardiac catheterization laboratory. To perform this, the diseased blood flow can be measured with a first pass distribution analysis and the theoretical normal blood flow can be estimated from the total coronary arterial volume based on scaling laws. A computer simulation of the coronary arterial network was used to gain a better understanding of how hemodynamic conditions and coronary artery disease can affect blood flow, arterial volume and FFR estimation. Changes in coronary arterial flow and volume due to coronary stenosis, aortic pressure and venous pressure were examined to evaluate the potential use of flow and volume for FFR determination. This study showed that FFR can be estimated using arterial volume and a scaling coefficient corrected for aortic pressure. However, variations in venous pressure were found to introduce some error in FFR estimation. A relative form of FFR was introduced and was found to cancel out the influence of pressure on coronary flow, arterial volume and FFR estimation. The use of coronary flow and arterial volume for FFR determination appears promising.

  1. A new Doppler-echo method to quantify regurgitant volume.

    PubMed

    Wang, S S; Rubenstein, J J; Goldman, M; Sidd, J J

    1992-01-01

    An in vitro technique using color flow imaging and continuous wave Doppler was developed to measure the initial regurgitant flow jet diameter and velocity integral to yield the parameters for a volume calculation. Jets were produced by volume-controlled injection through tubes of various diameters (1.3, 1.9, 2.8, and 3.5 mm) to deliver volumes from 1 to 7 ml over 100 to 300 msec at pressures from 40 to 200 mm Hg. One hundred forty-five samples were obtained. Flow jet diameter consistently overestimated tube diameter by 2 mm when injected volume was 1.5 to 7 ml and by 1.5 mm when injected volume was less than 1.5 ml. This offset was stable with various transducers (2.5, 3.5, 5.0 MHz) at normal gain setting (just under noise). Therefore, corrected flow jet diameter (FJD) = FJD - 2 mm, and Doppler volume = corrected flow jet area x velocity integral. A range of injectates from 1.1 to 7 ml generated Doppler volume of 1.0 to 8.2 ml. The relation between Doppler volume (DV) and injected volume (IV) was DV = 1.079 IV - 0.22, r2 = 0.945, p less than 0.01. This relation was not altered by tube diameter. Thus a method combining color flow imaging and continuous wave Doppler provides a reliable and accurate measure of in vitro flow volume.

  2. Factors influencing the measurement of closing volume.

    PubMed

    Make, B; Lapp, N L

    1975-06-01

    The various factors influencing closing volume were studied by performing the single-breath N2 test on 9 healthy nonsmokers. Time of day, day of the week, and preceding volume history had no effect on either closing volume or alveolar plateau. Slow inspiratory flow resulted in larger ratio of closing volume to vital capacity, ratio of closing capacity to total lung capacity, and change in N2 concentration than fast inspiratory flow. Voluntary regulation of the expiratory flow resulted in smaller ratios of closing volume to vital capacity and closing capacity to total lung capacity than when flow was regulated by a resistance. Prolonged breath holding of the inspired O2 led to larger ratio of closing volume to vital capacity and ratio of closing capacity to total lung capacity. To obtain uniform, comparable closing volumes, it is suggested that the subject inspire slowly, control expiratory flow (preferably voluntarily), and not pause between inspiration and expiration.

  3. Reliability testing of the Hughes temperature controlled 1/4 watt split cycle cryogenic cooler (HD-1045 (V)/UA)

    NASA Astrophysics Data System (ADS)

    Shaffer, James; Dunmire, Howard; Samuels, Raemon; Trively, Martin

    1989-12-01

    The U.S. Army CECOM Center for Night Vision and Electro-Optics (C2NVEO) is responsible for developing cryogenic coolers for all infrared imaging systems for the Army. C2NVEO also maintains configuration management control of the forward-looking infrared (FLIR) Common Module coolers used in thermal imagers in fielded Army weapon systems such as: M60A3 and M1 Tanks, Bradley Fighting Vehicle (BFV) System, tube-launched, optically tracked, wire-guided (TOW) Missile System, and Army Attack Helicopters. Currently, there are over 30,000 coolers in fielded systems and several thousand more are added each year. C2NVEO conducts development programs and monitors contractor internal research and development efforts to improve cooler performance such as reliability, audio noise, power consumption, and output vibration. The HD-1045 1/4-Watt Split Stirling Cooler was originally designed and developed by the C2NVEO in the early 1970s as a replacement for the gas bottle/cryostat used on the Manportable Common Thermal Night Sights. To date, however, the HD-1045 cooler has been used in the field in the Integrated Sight Unit (ISU) of the BFV System and is currently being used in the Driver Thermal Viewer (DTV) full scale development program. This document describes and reports the results of reliability testing done on Hughes Temperature Controlled 1/4 Watt split Cycle Cryogenic Coolers (HD-1045 (V)/UA), referred to herein as the coolers.

  4. Quantitative tomographic measurements of opaque multiphase flows

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    GEORGE,DARIN L.; TORCZYNSKI,JOHN R.; SHOLLENBERGER,KIM ANN

    2000-03-01

    An electrical-impedance tomography (EIT) system has been developed for quantitative measurements of radial phase distribution profiles in two-phase and three-phase vertical column flows. The EIT system is described along with the computer algorithm used for reconstructing phase volume fraction profiles. EIT measurements were validated by comparison with a gamma-densitometry tomography (GDT) system. The EIT system was used to accurately measure average solid volume fractions up to 0.05 in solid-liquid flows, and radial gas volume fraction profiles in gas-liquid flows with gas volume fractions up to 0.15. In both flows, average phase volume fractions and radial volume fraction profiles from GDTmore » and EIT were in good agreement. A minor modification to the formula used to relate conductivity data to phase volume fractions was found to improve agreement between the methods. GDT and EIT were then applied together to simultaneously measure the solid, liquid, and gas radial distributions within several vertical three-phase flows. For average solid volume fractions up to 0.30, the gas distribution for each gas flow rate was approximately independent of the amount of solids in the column. Measurements made with this EIT system demonstrate that EIT may be used successfully for noninvasive, quantitative measurements of dispersed multiphase flows.« less

  5. Capacitance probe for fluid flow and volume measurements

    NASA Technical Reports Server (NTRS)

    Arndt, G. Dickey (Inventor); Nguyen, Thanh X. (Inventor); Carl, James R. (Inventor)

    1995-01-01

    Method and apparatus for making measurements on fluids are disclosed, including the use of a capacitive probe for measuring the flow volume of a material within a flow stream. The capacitance probe has at least two elongate electrodes and, in a specific embodiment of the invention, has three parallel elongate electrodes with the center electrode being an extension of the center conductor of a co-axial cable. A conductance probe is also provided to provide more accurate flow volume data in response to conductivity of the material within the flow stream. A preferred embodiment of the present invention provides for a gas flow stream through a microgravity environment that allows for monitoring a flow volume of a fluid sample, such as a urine sample, that is entrained within the gas flow stream.

  6. Capacitance Probe for Fluid Flow and Volume Measurements

    NASA Technical Reports Server (NTRS)

    Arndt, G. Dickey (Inventor); Nguyen, Thanh X. (Inventor); Carl, James R. (Inventor)

    1997-01-01

    Method and apparatus for making measurements on fluids are disclosed, including the use of a capacitive probe for measuring the flow volume of a material within a flow stream. The capacitance probe has at least two elongate electrodes and, in a specific embodiment of the invention, has three parallel elongate electrodes with the center electrode being an extension of the center conductor of a co-axial cable. A conductance probe is also provided to provide more accurate flow volume data in response to conductivity of the material within the flow stream. A preferred embodiment of the present invention provides for a gas flow stream through a micro-gravity environment that allows for monitoring a flow volume of a fluid sample, such as a urine sample, that is entrained within the gas flow stream.

  7. ( sup 99m Tc)diphosphonate uptake and hemodynamics in arthritis of the immature dog knee

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hansen, E.S.; Soballe, K.; Henriksen, T.B.

    1991-03-01

    The relationship between (99mTc)diphosphonate uptake and bone hemodynamics was studied in canine carrageenan-induced juvenile chronic arthritis. Blood flow was determined with microspheres, plasma and red cell volumes were measured by labeled fibrinogen and red cells, and the microvascular volume and mean transit time of blood were calculated. Normal femoral epiphyses had lower central and higher subchondral blood flow and diphosphonate uptake values. Epiphyseal vascular volume was uniform, resulting in a greater transit time of blood centrally. In arthritis, blood flow and diphosphonate uptake were increased subchondrally and unaffected centrally, while epiphyseal vascular volume was increased throughout, leading to prolonged transitmore » time centrally. The normal metaphyses had low blood flow and diphosphonate uptake values in cancellous bone and very high values in growth plates, but a large vascular volume throughout. The mean transit time therefore was low in growth plates and high in adjacent cancellous bone. Arthritis caused decreased blood flow and diphosphonate uptake in growth plates but increased vascular volume and transit time of blood. Diphosphonate uptake correlated positively with blood flow and plasma volume and negatively with red cell volume in a nonlinear fashion. Thus, changes in diphosphonate uptake and microvascular hemodynamics occur in both epiphyseal and metaphyseal bone in chronic synovitis of the immature knee. The (99mTc)diphosphonate bone scan seems to reflect blood flow, plasma volume, and red cell volume of bone.« less

  8. Parent formulation at the Lagrangian level

    NASA Astrophysics Data System (ADS)

    Grigoriev, Maxim

    2011-07-01

    The recently proposed first-order parent formalism at the level of equations of motion is specialized to the case of Lagrangian systems. It is shown that for diffeomorphism-invariant theories the parent formulation takes the form of an AKSZ-type sigma model. The proposed formulation can be also seen as a Lagrangian version of the BV-BRST extension of the Vasiliev unfolded approach. We also discuss its possible interpretation as a multidimensional generalization of the Hamiltonian BFV-BRST formalism. The general construction is illustrated by examples of (parametrized) mechanics, relativistic particle, Yang-Mills theory, and gravity.

  9. Path-integral representation for the relativistic particle propagators and BFV quantization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fradkin, E.S.; Gitman, D.M.

    1991-11-15

    The path-integral representations for the propagators of scalar and spinor fields in an external electromagnetic field are derived. The Hamiltonian form of such expressions can be interpreted in the sense of Batalin-Fradkin-Vilkovisky quantization of one-particle theory. The Lagrangian representation as derived allows one to extract in a natural way the expressions for the corresponding gauge-invariant (reparametrization- and supergauge-invariant) actions for pointlike scalar and spinning particles. At the same time, the measure and ranges of integrations, admissible gauge conditions, and boundary conditions can be exactly established.

  10. Chiral superparticle and the full set of (1,0) supergravity constraints

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deriglazov, A.A.

    1993-03-10

    The author presents BFV quantization of manifestly Lorentz-covariant chiral particle action. Lagrangians for (1,1), (1,0), (0,1) chiral superparticles (CSP) invariant under the local Siegel-type transformations are considered; the mechanism of closing of local Siegel k-symmetry algebra in Lagrangian formulation for the (1,0) CSP is suggested. The full set of (1,0) supergravity constraints is obtained from the requirement of preserving local symmetries in a curved background. The possibility of extending the results to D = 10 case is discussed.

  11. Covariant spinor representation of iosp(d,2/2) and quantization of the spinning relativistic particle

    NASA Astrophysics Data System (ADS)

    Jarvis, P. D.; Corney, S. P.; Tsohantjis, I.

    1999-12-01

    A covariant spinor representation of iosp(d,2/2) is constructed for the quantization of the spinning relativistic particle. It is found that, with appropriately defined wavefunctions, this representation can be identified with the state space arising from the canonical extended BFV-BRST quantization of the spinning particle with admissible gauge fixing conditions after a contraction procedure. For this model, the cohomological determination of physical states can thus be obtained purely from the representation theory of the iosp(d,2/2) algebra.

  12. Surveillance of hemodialysis vascular access with ultrasound vector flow imaging

    NASA Astrophysics Data System (ADS)

    Brandt, Andreas H.; Olesen, Jacob B.; Hansen, Kristoffer L.; Rix, Marianne; Jensen, Jørgen A.; Nielsen, Michael B.

    2015-03-01

    The aim of this study was prospectively to monitor the volume flow in patients with arteriovenous fistula (AVF) with the angle independent ultrasound technique Vector Flow Imaging (VFI). Volume flow values were compared with Ultrasound dilution technique (UDT). Hemodialysis patients need a well-functioning vascular access with as few complications as possible and preferred vascular access is an AVF. Dysfunction due to stenosis is a common complication, and regular monitoring of volume flow is recommended to preserve AVF patency. UDT is considered the gold standard for volume flow surveillance, but VFI has proven to be more precise, when performing single repeated instantaneous measurements. Three patients with AVF were monitored with UDT and VFI monthly for five months. A commercial ultrasound scanner with a 9 MHz linear array transducer with integrated VFI was used to obtain data. UDT values were obtained with Transonic HD03 Flow-QC Hemodialysis Monitor. Three independent measurements at each scan session were obtained with UDT and VFI each month. Average deviation of volume flow between UDT and VFI was 25.7 % (Cl: 16.7% to 34.7%) (p= 0.73). The standard deviation for all patients, calculated from the mean variance of each individual scan sessions, was 199.8 ml/min for UDT and 47.6 ml/min for VFI (p = 0.002). VFI volume flow values were not significantly different from the corresponding estimates obtained using UDT, and VFI measurements were more precise than UDT. The study indicates that VFI can be used for surveillance of volume flow.

  13. The dependency of expiratory airway collapse on pump system and flow rate in liquid ventilated rabbits.

    PubMed

    Meinhardt, J P; Ashton, B A; Annich, G M; Quintel, M; Hirschl, R B

    2003-05-30

    To evaluate the influence of pump system and flow pattern on expiratory airway collapse (EAC) in total perfluorocarbon ventilation. - Prospective, controlled, randomized animal trial for determination of (1) post-mortem changes by repeated expiration procedures (EP) with a constant flow piston pump (PP) before and after sacrifice (n = 8 rabbits), (2) differences between pump systems by subjecting animals to both PP and roller pump (RP) circuits for expiration (n = 16 rabbits). EP were performed using a servo-controlled shut-off at airway pressures < 25 cm H subset 2O randomly with either pump at different flows. - Expired volumes before and after sacrifice were not significantly different. PP and RP revealed identical mean flows, while significantly more liquid was drained using PP (p<0.05). Increasing differences towards higher flow rates indicated profound flow pulsatility in RP. - (1) post-mortem changes in expired volumes are not significant, (2) EAC is related to flow rate and pump system; (3) relationship between expiratory flow rate and drainable liquid volume is linear inverse; (4) PP provides higher drainage than RP. - Expiratory airway collapse is related to flow rate and pump system, post mortem changes in expirable volumes are not significant. Relationship between expiratory flow rate and drainable liquid volume is linear inverse, piston pump expiration provides higher drainage volumes than roller pump expiration.

  14. Lung function in North American Indian children: reference standards for spirometry, maximal expiratory flow volume curves, and peak expiratory flow.

    PubMed

    Wall, M A; Olson, D; Bonn, B A; Creelman, T; Buist, A S

    1982-02-01

    Reference standards of lung function was determined in 176 healthy North American Indian children (94 girls, 82 boys) 7 to 18 yr of age. Spirometry, maximal expiratory flow volume curves, and peak expiratory flow rate were measured using techniques and equipment recommended by the American Thoracic Society. Standing height was found to be an accurate predictor of lung function, and prediction equations for each lung function variable are presented using standing height as the independent variable. Lung volumes and expiratory flow rates in North American Indian children were similar to those previously reported for white and Mexican-American children but were greater than those in black children. In both boys and girls, lung function increased in a curvilinear fashion. Volume-adjusted maximal expiratory flow rates after expiring 50 or 75% of FVC tended to decrease in both sexes as age and height increased. Our maximal expiratory flow volume curve data suggest that as North American Indian children grow, lung volume increases at a slightly faster rate than airway size does.

  15. Radial flow pulse jet mixer

    DOEpatents

    VanOsdol, John G.

    2013-06-25

    The disclosure provides a pulse jet mixing vessel for mixing a plurality of solid particles. The pulse jet mixing vessel is comprised of a sludge basin, a flow surface surrounding the sludge basin, and a downcoming flow annulus between the flow surface and an inner shroud. The pulse jet mixing vessel is additionally comprised of an upper vessel pressurization volume in fluid communication with the downcoming flow annulus, and an inner shroud surge volume separated from the downcoming flow annulus by the inner shroud. When the solid particles are resting on the sludge basin and a fluid such as water is atop the particles and extending into the downcoming flow annulus and the inner shroud surge volume, mixing occurs by pressurization of the upper vessel pressurization volume, generating an inward radial flow over the flow surface and an upwash jet at the center of the sludge basin.

  16. In vitro validation of a Pitot-based flow meter for the measurement of respiratory volume and flow in large animal anaesthesia.

    PubMed

    Moens, Yves P S; Gootjes, Peter; Ionita, Jean-Claude; Heinonen, Erkki; Schatzmann, Urs

    2009-05-01

    To remodel and validate commercially available monitors and their Pitot tube-based flow sensors for use in large animals, using in vitro techniques. Prospective, in vitro experiment. Both the original and the remodelled sensor were studied with a reference flow generator. Measurements were taken of the static flow-pressure relationship and linearity of the flow signal. Sensor airway resistance was calculated. Following recalibration of the host monitor, volumes ranging from 1 to 7 L were generated by a calibration syringe, and bias and precision of spirometric volume was determined. Where manual recalibration was not available, a conversion factor for volume measurement was determined. The influence of gas composition mixture and peak flow on the conversion factor was studied. Both the original and the remodelled sensor showed similar static flow-pressure relationships and linearity of the flow signal. Mean bias (%) of displayed values compared with the reference volume of 3, 5 and 7 L varied between -0.4% and +2.4%, and this was significantly smaller than that for 1 L (4.8% to +5.0%). Conversion factors for 3, 5 and 7 L were very similar (mean 6.00 +/- 0.2, range 5.91-6.06) and were not significantly influenced by the gas mixture used. Increasing peak flow caused a small decrease in the conversion factor. Volume measurement error and conversion factors for inspiration and expiration were close to identity. The combination of the host monitor with the remodelled flow sensor allowed accurate in vitro measurement of flows and volumes in a range expected during large animal anaesthesia. This combination has potential as a reliable spirometric monitor for use during large animal anaesthesia.

  17. Distribution of extravascular fluid volumes in isolated perfused lungs measured with H215O.

    PubMed Central

    Jones, T; Jones, H A; Rhodes, C G; Buckingham, P D; Hughes, J M

    1976-01-01

    The distributions per unit volume of extravascular water (EVLW), blood volume, and blood flow were measured in isolated perfused vertical dog lungs. A steady-state tracer technique was employed using oxygen-15, carbon-11, and nitrogen-13 isotopes and external scintillation counting of the 511-KeV annihilation radiation common to all three radionuclides. EVLW, and blood volume and flow increased from apex to base in all preparations, but the gradient of increasing flow exceeded that for blood and EVLW volumes. The regional distributions of EVLW and blood volume were almost identical. With increasing edema, lower-zone EVLW increased slightly relative to that in the upper zone. There was no change in the distribution of blood volume or flow until gross edema (100% wt gain) occurred when lower zone values were reduced. In four lungs the distribution of EVLW was compared with wet-to-dry ratios from lung biopsies taken immediately afterwards. Whereas the isotopically measured EVLW increased from apex to base, the wet-to-dry weight ratios remained essentially uniform. We concluded that isotopic methods measure only an "exchangeable" water pool whose volume is dependent on regional blood flow and capillary recruitment. Second, the isolated perfused lung can accommodate up to 60% wt gain without much change in the regional distribution of EVLW, volume, or flow. PMID:765354

  18. Extended parametric representation of compressor fans and turbines. Volume 2: Part user's manual (parametric turbine)

    NASA Technical Reports Server (NTRS)

    Coverse, G. L.

    1984-01-01

    A turbine modeling technique has been developed which will enable the user to obtain consistent and rapid off-design performance from design point input. This technique is applicable to both axial and radial flow turbine with flow sizes ranging from about one pound per second to several hundred pounds per second. The axial flow turbines may or may not include variable geometry in the first stage nozzle. A user-specified option will also permit the calculation of design point cooling flow levels and corresponding changes in efficiency for the axial flow turbines. The modeling technique has been incorporated into a time-sharing program in order to facilitate its use. Because this report contains a description of the input output data, values of typical inputs, and example cases, it is suitable as a user's manual. This report is the second of a three volume set. The titles of the three volumes are as follows: (1) Volume 1 CMGEN USER's Manual (Parametric Compressor Generator); (2) Volume 2 PART USER's Manual (Parametric Turbine); (3) Volume 3 MODFAN USER's Manual (Parametric Modulation Flow Fan).

  19. Flow volume loops in patients with goiters.

    PubMed Central

    Geraghty, J G; Coveney, E C; Kiernan, M; O'Higgins, N J

    1992-01-01

    Plain radiology is the standard means of assessing upper airway obstruction in patients with goiters. Flow volume loop curves will provide additional information, because they allow a quantitative assessment of airflow dynamics in the respiratory cycle. Fifty-one patients had flow volume loops performed before and after thyroidectomy. There was a significant increase in the maximum inspiratory flow rate (3.9 +/- 0.2 versus 4.9 +/- 0.2 L/second, p less than 0.01) after thyroidectomy. Eight of twelve patients with normal tracheal radiology had improved airflow dynamics in the postoperative period. The flow volume loop curve is a simple noninvasive means of assessing airflow dynamics in patients with goiters and may be superior to conventional radiology. PMID:1731653

  20. Evaluation of a new 3-dimensional color Doppler flow method to quantify flow across the mitral valve and in the left ventricular outflow tract: an in vitro study.

    PubMed

    Kimura, Sumito; Streiff, Cole; Zhu, Meihua; Shimada, Eriko; Datta, Saurabh; Ashraf, Muhammad; Sahn, David J

    2014-02-01

    The aim of this study was to assess the accuracy, feasibility, and reproducibility of determining stroke volume from a novel 3-dimensional (3D) color Doppler flow quantification method for mitral valve (MV) inflow and left ventricular outflow tract (LVOT) outflow at different stroke volumes when compared with the actual flow rate in a pumped porcine cardiac model. Thirteen freshly harvested pig hearts were studied in a water tank. We inserted a latex balloon into each left ventricle from the MV annulus to the LVOT, which were passively pumped at different stroke volumes (30-80 mL) using a calibrated piston pump at increments of 10 mL. Four-dimensional flow volumes were obtained without electrocardiographic gating. The digital imaging data were analyzed offline using prototype software. Two hemispheric flow-sampling planes for color Doppler velocity measurements were placed at the MV annulus and LVOT. The software computed the flow volumes at the MV annulus and LVOT within the user-defined volume and cardiac cycle. This novel 3D Doppler flow quantification method detected incremental increases in MV inflow and LVOT outflow in close agreement with pumped stroke volumes (MV inflow, r = 0.96; LVOT outflow, r = 0.96; P < .01). Bland-Altman analysis demonstrated overestimation of both (MV inflow, 5.42 mL; LVOT outflow, 4.46 mL) with 95% of points within 95% limits of agreement. Interobserver variability values showed good agreement for all stroke volumes at both the MV annulus and LVOT. This study has shown that the 3D color Doppler flow quantification method we used is able to compute stroke volumes accurately at the MV annulus and LVOT in the same cardiac cycle without electrocardiographic gating. This method may be valuable for assessment of cardiac output in clinical studies.

  1. Variability in venom volume, flow rate and duration in defensive stings of five scorpion species.

    PubMed

    van der Meijden, Arie; Coelho, Pedro; Rasko, Mykola

    2015-06-15

    Scorpions have been shown to control their venom usage in defensive encounters, depending on the perceived threat. Potentially, the venom amount that is injected could be controlled by reducing the flow speed, the flow duration, or both. We here investigated these variables by allowing scorpions to sting into an oil-filled chamber, and recording the accreting venom droplets with high-speed video. The size of the spherical droplets on the video can then be used to calculate their volume. We recorded defensive stings of 20 specimens representing 5 species. Significant differences in the flow rate and total expelled volume were found between species. These differences are likely due to differences in overall size between the species. Large variation in both venom flow speed and duration are described between stinging events of single individuals. Both venom flow rate and flow duration correlate highly with the total expelled volume, indicating that scorpions may control both variables in order to achieve a desired end volume of venom during a sting. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Impacts of changing hydrology on permanent gully growth: experimental results

    NASA Astrophysics Data System (ADS)

    Day, Stephanie S.; Gran, Karen B.; Paola, Chris

    2018-06-01

    Permanent gullies grow through head cut propagation in response to overland flow coupled with incision and widening in the channel bottom leading to hillslope failures. Altered hydrology can impact the rate at which permanent gullies grow by changing head cut propagation, channel incision, and channel widening rates. Using a set of small physical experiments, we tested how changing overland flow rates and flow volumes alter the total volume of erosion and resulting gully morphology. Permanent gullies were modeled as both detachment-limited and transport-limited systems, using two different substrates with varying cohesion. In both cases, the erosion rate varied linearly with water discharge, such that the volume of sediment eroded was a function not of flow rate, but of total water volume. This implies that efforts to reduce peak flow rates alone without addressing flow volumes entering gully systems may not reduce erosion. The documented response in these experiments is not typical when compared to larger preexisting channels where higher flow rates result in greater erosion through nonlinear relationships between water discharge and sediment discharge. Permanent gullies do not respond like preexisting channels because channel slope remains a free parameter and can adjust relatively quickly in response to changing flows.

  3. Transition amplitude for two-time physics

    NASA Astrophysics Data System (ADS)

    Frederico, João E.; Rivelles, Victor O.

    2010-07-01

    We present the transition amplitude for a particle moving in a space with two times and D space dimensions having an Sp(2,R) local symmetry and an SO(D,2) rigid symmetry. It was obtained from the BRST-BFV quantization with a unique gauge choice. We show that by constraining the initial and final points of this amplitude to lie on some hypersurface of the D+2 space the resulting amplitude reproduces well-known systems in lower dimensions. This work provides an alternative way to derive the effects of two-time physics where all the results come from a single transition amplitude.

  4. D=10 Chiral Tensionless Super p-BRANES

    NASA Astrophysics Data System (ADS)

    Bozhilov, P.

    We consider a model for tensionless (null) super-p-branes with N chiral supersymmetries in ten-dimensional flat space-time. After establishing the symmetries of the action, we give the general solution of the classical equations of motion in a particular gauge. In the case of a null superstring (p=1) we find the general solution in an arbitrary gauge. Then, using a harmonic superspace approach, the initial algebra of first- and second-class constraints is converted into an algebra of Lorentz-covariant, BFV-irreducible, first-class constraints only. The corresponding BRST charge is as for a first rank dynamical system.

  5. Generalized scalar particle quantization in 1+1 dimensions and D(2,1;α)

    NASA Astrophysics Data System (ADS)

    Corney, S. P.; Jarvis, P. D.; Tsohantjis, I.; McAnally, D. S.

    2001-05-01

    The exceptional superalgebra D(2,1;α) has been classified as a candidate conformal supersymmetry algebra in two dimensions. We propose an alternative interpretation of it as an extended BFV-BRST quantization superalgebra in 2D (D(2,1;1)≃osp(2,2|2)). A superfield realization is presented wherein the standard extended phase space coordinates can be identified. The physical states are studied via the cohomology of the BRST operator. Finally we reverse engineer a classical action corresponding to the algebraic model we have constructed, and identify the Lagrangian equations of motion.

  6. On the Existence of Star Products on Quotient Spaces of Linear Hamiltonian Torus Actions

    NASA Astrophysics Data System (ADS)

    Herbig, Hans-Christian; Iyengar, Srikanth B.; Pflaum, Markus J.

    2009-08-01

    We discuss BFV deformation quantization (Bordemann et al. in A homological approach to singular reduction in deformation quantization, singularity theory, pp. 443-461. World Scientific, Hackensack, 2007) in the special case of a linear Hamiltonian torus action. In particular, we show that the Koszul complex on the moment map of an effective linear Hamiltonian torus action is acyclic. We rephrase the nonpositivity condition of Arms and Gotay (Adv Math 79(1):43-103, 1990) for linear Hamiltonian torus actions. It follows that reduced spaces of such actions admit continuous star products.

  7. Transition amplitude for two-time physics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frederico, Joao E.; Rivelles, Victor O.; Instituto de Fisica, Universidade de Sao Paulo, Caixa Postal 66318, 05314-970, Sao Paulo, SP

    2010-07-15

    We present the transition amplitude for a particle moving in a space with two times and D space dimensions having an Sp(2,R) local symmetry and an SO(D,2) rigid symmetry. It was obtained from the BRST-BFV quantization with a unique gauge choice. We show that by constraining the initial and final points of this amplitude to lie on some hypersurface of the D+2 space the resulting amplitude reproduces well-known systems in lower dimensions. This work provides an alternative way to derive the effects of two-time physics where all the results come from a single transition amplitude.

  8. Development of a Physical Employment Testing Battery for Infantry Soldiers: 11B Infantryman and 11C Infantryman - Indirect Fire

    DTIC Science & Technology

    2015-12-01

    25mm barrel install (Task 5) and engage targets with an M2 machine gun (Task 12). During these tasks, the performance of one individual will affect...TOW Missile Launcher on BFV (Task 8) 43 1.9 Images of Move Under Direct Fire (Task 10) 44 1.10 Engage Targets with a .50 Caliber M2 Machine Gun ...Engage Targets with a .50 Caliber M2 Machine Gun While wearing a fighting load (approximately 83 lb) and working as a member of a two-person team

  9. Direct measurement of proximal isovelocity surface area by real-time three-dimensional color Doppler for quantitation of aortic regurgitant volume: an in vitro validation.

    PubMed

    Pirat, Bahar; Little, Stephen H; Igo, Stephen R; McCulloch, Marti; Nosé, Yukihiko; Hartley, Craig J; Zoghbi, William A

    2009-03-01

    The proximal isovelocity surface area (PISA) method is useful in the quantitation of aortic regurgitation (AR). We hypothesized that actual measurement of PISA provided with real-time 3-dimensional (3D) color Doppler yields more accurate regurgitant volumes than those estimated by 2-dimensional (2D) color Doppler PISA. We developed a pulsatile flow model for AR with an imaging chamber in which interchangeable regurgitant orifices with defined shapes and areas were incorporated. An ultrasonic flow meter was used to calculate the reference regurgitant volumes. A total of 29 different flow conditions for 5 orifices with different shapes were tested at a rate of 72 beats/min. 2D PISA was calculated as 2pi r(2), and 3D PISA was measured from 8 equidistant radial planes of the 3D PISA. Regurgitant volume was derived as PISA x aliasing velocity x time velocity integral of AR/peak AR velocity. Regurgitant volumes by flow meter ranged between 12.6 and 30.6 mL/beat (mean 21.4 +/- 5.5 mL/beat). Regurgitant volumes estimated by 2D PISA correlated well with volumes measured by flow meter (r = 0.69); however, a significant underestimation was observed (y = 0.5x + 0.6). Correlation with flow meter volumes was stronger for 3D PISA-derived regurgitant volumes (r = 0.83); significantly less underestimation of regurgitant volumes was seen, with a regression line close to identity (y = 0.9x + 3.9). Direct measurement of PISA is feasible, without geometric assumptions, using real-time 3D color Doppler. Calculation of aortic regurgitant volumes with 3D color Doppler using this methodology is more accurate than conventional 2D method with hemispheric PISA assumption.

  10. Empirical models for predicting volumes of sediment deposited by debris flows and sediment-laden floods in the transverse ranges of southern California

    USGS Publications Warehouse

    Gartner, Joseph E.; Cannon, Susan H.; Santi, Paul M

    2014-01-01

    Debris flows and sediment-laden floods in the Transverse Ranges of southern California pose severe hazards to nearby communities and infrastructure. Frequent wildfires denude hillslopes and increase the likelihood of these hazardous events. Debris-retention basins protect communities and infrastructure from the impacts of debris flows and sediment-laden floods and also provide critical data for volumes of sediment deposited at watershed outlets. In this study, we supplement existing data for the volumes of sediment deposited at watershed outlets with newly acquired data to develop new empirical models for predicting volumes of sediment produced by watersheds located in the Transverse Ranges of southern California. The sediment volume data represent a broad sample of conditions found in Ventura, Los Angeles and San Bernardino Counties, California. The measured volumes of sediment, watershed morphology, distributions of burn severity within each watershed, the time since the most recent fire, triggering storm rainfall conditions, and engineering soil properties were analyzed using multiple linear regressions to develop two models. A “long-term model” was developed for predicting volumes of sediment deposited by both debris flows and floods at various times since the most recent fire from a database of volumes of sediment deposited by a combination of debris flows and sediment-laden floods with no time limit since the most recent fire (n = 344). A subset of this database was used to develop an “emergency assessment model” for predicting volumes of sediment deposited by debris flows within two years of a fire (n = 92). Prior to developing the models, 32 volumes of sediment, and related parameters for watershed morphology, burn severity and rainfall conditions were retained to independently validate the long-term model. Ten of these volumes of sediment were deposited by debris flows within two years of a fire and were used to validate the emergency assessment model. The models were validated by comparing predicted and measured volumes of sediment. These validations were also performed for previously developed models and identify that the models developed here best predict volumes of sediment for burned watersheds in comparison to previously developed models.

  11. Decrease of pulmonary blood flow detected by phase contrast MRI is correlated with a decrease in lung volume and increase of lung fibrosis area determined by computed tomography in interstitial lung disease.

    PubMed

    Tsuchiya, Nanae; Yamashiro, Tsuneo; Murayama, Sadayuki

    2016-09-01

    Lung volume and pulmonary blood flow decrease in patients with interstitial lung disease (ILD). The purpose of this study was to assess the relationship between pulmonary blood flow and lung volume in ILD patients. This research was approved by the institutional review board. Twenty-seven patients (9 men, 18 women; mean age, 59 years; range, 24-79 years) with ILD were included. Blood flow was assessed in the pulmonary trunk and the left and right pulmonary arteries by phase contrast magnetic resonance imaging (MRI). Lung volume and the computed tomography (CT) visual score that indicates the severity of ILD were assessed on the left and right sides by thin-section CT scanning. Lung volume was automatically measured by lung analysis software (VINCENT Ver. 4). The CT visual score was measured by averaging the proportion of abnormal lung area at five anatomic levels. Pearson's correlation coefficient was used to determine the relationship between pulmonary blood flow and lung volume. Pulmonary blood flow showed a significant correlation with lung volume (both: r=0.52, p=0.006; left: r=0.61, p=0.001; right: r=0.54, p=0.004) and CT visual score (both: r=-0.39, p=0.04; left: r=-0.48, p=0.01; right: r=-0.38, p=0.04). Partial correlation analysis, controlled for age, height and weight, showed a significant correlation between pulmonary blood flow and lung volume (both: r=0.43, p=0.03; left: r=0.55, p=0.005; right: r=0.48, p=0.01) and CT visual score (both: r=-0.58, p=0.003; left: r=-0.51, p=0.01; right: r=-0.64, p=0.001). In ILD, reduced pulmonary blood flow is associated with reduced lung volume and increased abnormal lung area. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  12. Gravitational potential wells and the cosmic bulk flow

    NASA Astrophysics Data System (ADS)

    Wang, Yuyu; Kumar, Abhinav; Feldman, Hume; Watkins, Richard

    2016-03-01

    The bulk flow is a volume average of the peculiar velocities and a useful probe of the mass distribution on large scales. The gravitational instability model views the bulk flow as a potential flow that obeys a Maxwellian Distribution. We use two N-body simulations, the LasDamas Carmen and the Horizon Run, to calculate the bulk flows of various sized volumes in the simulation boxes. Once we have the bulk flow velocities as a function of scale, we investigate the mass and gravitational potential distribution around the volume. We found that matter densities can be asymmetrical and difficult to detect in real surveys, however, the gravitational potential and its gradient may provide better tools to investigate the underlying matter distribution. This study shows that bulk flows are indeed potential flows and thus provides information on the flow sources. We also show that bulk flow magnitudes follow a Maxwellian distribution on scales > 10h-1 Mpc.

  13. Predictive Value of Dynamic Cerebral Autoregulation Assessment in Surgical Management of Patients with High-Grade Carotid Artery Stenosis

    PubMed Central

    Semenyutin, Vladimir B.; Asaturyan, Gregory A.; Nikiforova, Anna A.; Aliev, Vugar A.; Panuntsev, Grigory K.; Iblyaminov, Vadim B.; Savello, Alexander V.; Patzak, Andreas

    2017-01-01

    Dynamic cerebral autoregulation (DCA) capacity along with the degree of internal carotid artery (ICA) stenosis and characteristics of the plaque can also play an important role in selection of appropriate treatment strategy. This study aims to classify the patients with severe ICA stenosis according to preoperative state of DCA and to assess its dynamics after surgery. Thirty-five patients with severe ICA stenosis having different clinical type of disease underwent reconstructive surgery. DCA was assessed with transfer function analysis (TFA) by calculating phase shift (PS) between Mayer waves of blood flow velocity (BFV) and blood pressure (BP) before and after operation. In 18 cases, regardless of clinical type, preoperative PS on ipsilateral side was within the normal range and did not change considerably after surgery. In other 17 cases preoperative PS was reliably lower both in patients with symptomatic and asymptomatic stenosis. Surgical reconstruction led to restoration of impaired DCA evidenced by significant increase of PS in postoperative period. Our data suggest that regardless clinical type of disease various state of DCA may be present in patients with severe ICA stenosis. This finding can contribute to establishing the optimal treatment strategy, and first of all for asymptomatic patients. Patients with compromised DCA should be considered as ones with higher risk of stroke and first candidates for reconstructive surgery. PMID:29163214

  14. Regional Blood Volume and Peripheral Blood Flow in the Postural Tachycardia Syndrome

    PubMed Central

    Stewart, Julian M.; Montgomery, Leslie D.

    2015-01-01

    Variants of postural tachycardia syndrome (POTS) are associated with increased (“high flow” POTS, HFP), decreased (“low flow POTS”, LFP) and normal (“normal flow POTS”, NFP) blood flow measured in the lower extremities while supine. We propose that postural tachycardia is related to thoracic hypovolemia during orthostasis but that the patterns of peripheral blood flow relate to different mechanisms for thoracic hypovolemia. We studied 37 POTS patients aged 14-21 years: 14 LFP, 15 NFP and 8 HFP patients and 12 healthy control subjects. Peripheral blood flow was measured supine by venous occlusion strain gauge plethysmography of the forearm and calf in order to subgroup patients. Using indocyanine green techniques we showed decreased cardiac index (CI) and increased total peripheral resistance (TPR) in LFP, increased CI and decreased TPR in HFP, and unchanged CI and TPR in NFP while supine compared to control subjects. Blood volume tended to be decreased in LFP compared to control subjects. We used impedance plethysmography to assess regional blood volume redistribution during upright tilt. Thoracic blood volume decreased while splanchnic, pelvic and leg blood volumes increased for all subjects during orthostasis, but were markedly lower than control for all POTS groups. Splanchnic volume was increased in NFP and LFP. Pelvic blood volume was increased in HFP only. Calf volume was increased above control in HFP and LFP. The results support the hypothesis of [at least] three pathophysiologic variants of POTS distinguished by peripheral blood flow related to characteristic changes in regional circulations. The data demonstrate enhanced thoracic hypovolemia during upright tilt and confirm that POTS is related to inadequate cardiac venous return during orthostasis. PMID:15117717

  15. Hydrologic modeling of two glaciated watersheds in Northeast Pennsylvania

    USGS Publications Warehouse

    Srinivasan, M.S.; Hamlett, J.M.; Day, R.L.; Sams, J.I.; Petersen, G.W.

    1998-01-01

    A hydrologic modeling study, using the Hydrologic Simulation Program - FORTRAN (HSPF), was conducted in two glaciated watersheds, Purdy Creek and Ariel Creek in northeastern Pennsylvania. Both watersheds have wetlands and poorly drained soils due to low hydraulic conductivity and presence of fragipans. The HSPF model was calibrated in the Purdy Creek watershed and verified in the Ariel Creek watershed for June 1992 to December 1993 period. In Purdy Creek, the total volume of observed streamflow during the entire simulation period was 13.36 x 106 m3 and the simulated streamflow volume was 13.82 x 106 m3 (5 percent difference). For the verification simulation in Ariel Creek, the difference between the total observed and simulated flow volumes was 17 percent. Simulated peak flow discharges were within two hours of the observed for 30 of 46 peak flow events (discharge greater than 0.1 m3/sec) in Purdy Creek and 27 of 53 events in Ariel Creek. For 22 of the 46 events in Purdy Creek and 24 of 53 in Ariel Creek, the differences between the observed and simulated peak discharge rates were less than 30 percent. These 22 events accounted for 63 percent of total volume of streamflow observed during the selected 46 peak flow events in Purdy Creek. In Ariel Creek, these 24 peak flow events accounted for 62 percent of the total flow observed during all peak flow events. Differences in observed and simulated peak flow rates and volumes (on a percent basis) were greater during the snowmelt runoff events and summer periods than for other times.A hydrologic modeling study, using the Hydrologic Simulation Program - FORTRAN (HSPF), was conducted in two glaciated watersheds, Purdy Creek and Ariel Creek in northeastern Pennsylvania. Both watersheds have wetlands and poorly drained soils due to low hydraulic conductivity and presence of fragipans. The HSPF model was calibrated in the Purdy Creek watershed and verified in the Ariel Creek watershed for June 1992 to December 1993 period. In Purdy Creek, the total volume of observed streamflow during the entire simulation period was 13.36??106 m3 and the simulated streamflow volume was 13.82??106 m3 (5 percent difference). For the verification simulation in Ariel Creek, the difference between the total observed and simulated flow volumes was 17 percent. Simulated peak flow discharges were within two hours of the observed for 30 of 46 peak flow events (discharge greater than 0.1 m3/sec) in Purdy Creek and 27 of 53 events in Ariel Creek. For 22 of the 46 events in Purdy Creek and 24 of 53 in Ariel Creek, the differences between the observed and simulated peak discharge rates were less than 30 percent. These 22 events accounted for 63 percent of total volume of streamflow observed during the selected 46 peak flow events in Purdy Creek. In Ariel Creek, these 24 peak flow events accounted for 62 percent of the total flow observed during all peak flow events. Differences in observed and simulated peak flow rates and volumes (on a percent basis) were greater during the snowmelt runoff events and summer periods than for other times.

  16. Gas flow meter and method for measuring gas flow rate

    DOEpatents

    Robertson, Eric P.

    2006-08-01

    A gas flow rate meter includes an upstream line and two chambers having substantially equal, fixed volumes. An adjustable valve may direct the gas flow through the upstream line to either of the two chambers. A pressure monitoring device may be configured to prompt valve adjustments, directing the gas flow to an alternate chamber each time a pre-set pressure in the upstream line is reached. A method of measuring the gas flow rate measures the time required for the pressure in the upstream line to reach the pre-set pressure. The volume of the chamber and upstream line are known and fixed, thus the time required for the increase in pressure may be used to determine the flow rate of the gas. Another method of measuring the gas flow rate uses two pressure measurements of a fixed volume, taken at different times, to determine the flow rate of the gas.

  17. Preventing Molecular and Particulate Infiltration in a Confined Volume

    NASA Technical Reports Server (NTRS)

    Scialdone, John J.

    1999-01-01

    Contaminants from an instrument's self-generated sources or from sources external to the instrument may degrade its critical surfaces and/or create an environment which limits the instrument's intended performance. Analyses have been carried out on a method to investigate the required purging flow of clean, dry gas to prevent the ingestion of external contaminants into the instrument container volume. The pressure to be maintained and the required flow are examined in terms of their effectiveness in preventing gaseous and particulate contaminant ingestion and abatement of self-generated contaminants in the volume. The required venting area or the existing volume venting area is correlated to the volume to be purged, the allowable pressure differential across the volume, the external contaminant partial pressure, and the sizes of the ambient particulates. The diffusion of external water vapor into the volume while it was being purged was experimentally obtained in terms of an infiltration time constant. That data and the acceptable fraction of the outside pressure into the volume indicate the required flow of purge gas expressed in terms of volume change per unit time. The exclusion of particulates is based on the incoming velocity of the particles and the exit flow speed and density of the purge gas. The purging flow pressures needed to maintain the required flows through the vent passages are indicated. The purge gas must prevent or limit the entrance of the external contaminants to the critical locations of the instrument. It should also prevent self- contamination from surfaces, reduce material outgassing, and sweep out the outgassed products. Systems and facilities that can benefit from purging may be optical equipment, clinical facilities, manufacturing facilities, clean rooms, and other systems requiring clean environments.

  18. Direct Measurement of Proximal Isovelocity Surface Area by Real-Time Three-Dimensional Color Doppler for Quantitation of Aortic Regurgitant Volume: An In Vitro Validation

    PubMed Central

    Pirat, Bahar; Little, Stephen H.; Igo, Stephen R.; McCulloch, Marti; Nosé, Yukihiko; Hartley, Craig J.; Zoghbi, William A.

    2012-01-01

    Objective The proximal isovelocity surface area (PISA) method is useful in the quantitation of aortic regurgitation (AR). We hypothesized that actual measurement of PISA provided with real-time 3-dimensional (3D) color Doppler yields more accurate regurgitant volumes than those estimated by 2-dimensional (2D) color Doppler PISA. Methods We developed a pulsatile flow model for AR with an imaging chamber in which interchangeable regurgitant orifices with defined shapes and areas were incorporated. An ultrasonic flow meter was used to calculate the reference regurgitant volumes. A total of 29 different flow conditions for 5 orifices with different shapes were tested at a rate of 72 beats/min. 2D PISA was calculated as 2π r2, and 3D PISA was measured from 8 equidistant radial planes of the 3D PISA. Regurgitant volume was derived as PISA × aliasing velocity × time velocity integral of AR/peak AR velocity. Results Regurgitant volumes by flow meter ranged between 12.6 and 30.6 mL/beat (mean 21.4 ± 5.5 mL/beat). Regurgitant volumes estimated by 2D PISA correlated well with volumes measured by flow meter (r = 0.69); however, a significant underestimation was observed (y = 0.5x + 0.6). Correlation with flow meter volumes was stronger for 3D PISA-derived regurgitant volumes (r = 0.83); significantly less underestimation of regurgitant volumes was seen, with a regression line close to identity (y = 0.9x + 3.9). Conclusion Direct measurement of PISA is feasible, without geometric assumptions, using real-time 3D color Doppler. Calculation of aortic regurgitant volumes with 3D color Doppler using this methodology is more accurate than conventional 2D method with hemispheric PISA assumption. PMID:19168322

  19. Assessment and monitoring of flow limitation and other parameters from flow/volume loops.

    PubMed

    Dueck, R

    2000-01-01

    Flow/volume (F/V) spirometry is routinely used for assessing the type and severity of lung disease. Forced vital capacity (FVC) and timed vital capacity (FEV1) provide the best estimates of airflow obstruction in patients with asthma, chronic obstructive pulmonary disease (COPD) and emphysema. Computerized spirometers are now available for early home recognition of asthma exacerbation in high risk patients with severe persistent disease, and for recognition of either infection or rejection in lung transplant patients. Patients with severe COPD may exhibit expiratory flow limitation (EFL) on tidal volume (VT) expiratory F/V (VTF/V) curves, either with or without applying negative expiratory pressure (NEP). EFL results in dynamic hyperinflation and persistently raised alveolar pressure or intrinsic PEEP (PEEPi). Hyperinflation and raised PEEPi greatly enhance dyspnea with exertion through the added work of the threshold load needed to overcome raised pleural pressure. Esophageal (pleural) pressure monitoring may be added to VTF/V loops for assessing the severity of PEEPi: 1) to optimize assisted ventilation by mask or via endotracheal tube with high inspiratory flow rates to lower I:E ratio, and 2) to assess the efficacy of either pressure support ventilation (PSV) or low level extrinsic PEEP in reducing the threshold load of PEEPi. Intraoperative tidal volume F/V loops can also be used to document the efficacy of emphysema lung volume reduction surgery (LVRS) via disappearance of EFL. Finally, the mechanism of ventilatory constraint can be identified with the use of exercise tidal volume F/V loops referenced to maximum F/V loops and static lung volumes. Patients with severe COPD show inspiratory F/V loops approaching 95% of total lung capacity, and flow limitation over the entire expiratory F/V curve during light levels of exercise. Surprisingly, patients with a history of congestive heart failure may lower lung volume towards residual volume during exercise, thereby reducing airway diameter and inducing expiratory flow limitation.

  20. Gas Flow in the Capillary of the Atmosphere-to-Vacuum Interface of Mass Spectrometers

    NASA Astrophysics Data System (ADS)

    Skoblin, Michael; Chudinov, Alexey; Soulimenkov, Ilia; Brusov, Vladimir; Kozlovskiy, Viacheslav

    2017-10-01

    Numerical simulations of a gas flow through a capillary being a part of mass spectrometer atmospheric interface were performed using a detailed laminar flow model. The simulated interface consisted of atmospheric and forevacuum volumes connected via a thin capillary. The pressure in the forevacuum volume where the gas was expanding after passing through the capillary was varied in the wide range from 10 to 900 mbar in order to study the volume flow rate as well as the other flow parameters as functions of the pressure drop between the atmospheric and forevacuum volumes. The capillary wall temperature was varied in the range from 24 to 150 °C. Numerical integration of the complete system of Navier-Stokes equations for a viscous compressible gas taking into account the heat transfer was performed using the standard gas dynamic simulation software package ANSYS CFX. The simulation results were compared with experimental measurements of gas flow parameters both performed using our experimental setup and taken from the literature. The simulated volume flow rates through the capillary differed no more than by 10% from the measured ones over the entire pressure and temperatures ranges. A conclusion was drawn that the detailed digital laminar model is able to quantitatively describe the measured gas flow rates through the capillaries under conditions considered. [Figure not available: see fulltext.

  1. Gas Flow in the Capillary of the Atmosphere-to-Vacuum Interface of Mass Spectrometers.

    PubMed

    Skoblin, Michael; Chudinov, Alexey; Soulimenkov, Ilia; Brusov, Vladimir; Kozlovskiy, Viacheslav

    2017-10-01

    Numerical simulations of a gas flow through a capillary being a part of mass spectrometer atmospheric interface were performed using a detailed laminar flow model. The simulated interface consisted of atmospheric and forevacuum volumes connected via a thin capillary. The pressure in the forevacuum volume where the gas was expanding after passing through the capillary was varied in the wide range from 10 to 900 mbar in order to study the volume flow rate as well as the other flow parameters as functions of the pressure drop between the atmospheric and forevacuum volumes. The capillary wall temperature was varied in the range from 24 to 150 °C. Numerical integration of the complete system of Navier-Stokes equations for a viscous compressible gas taking into account the heat transfer was performed using the standard gas dynamic simulation software package ANSYS CFX. The simulation results were compared with experimental measurements of gas flow parameters both performed using our experimental setup and taken from the literature. The simulated volume flow rates through the capillary differed no more than by 10% from the measured ones over the entire pressure and temperatures ranges. A conclusion was drawn that the detailed digital laminar model is able to quantitatively describe the measured gas flow rates through the capillaries under conditions considered. Graphical Abstract ᅟ.

  2. Mapping debris-flow hazard in Honolulu using a DEM

    USGS Publications Warehouse

    Ellen, Stephen D.; Mark, Robert K.; ,

    1993-01-01

    A method for mapping hazard posed by debris flows has been developed and applied to an area near Honolulu, Hawaii. The method uses studies of past debris flows to characterize sites of initiation, volume at initiation, and volume-change behavior during flow. Digital simulations of debris flows based on these characteristics are then routed through a digital elevation model (DEM) to estimate degree of hazard over the area.

  3. Preoperative computer simulation for planning of vascular access surgery in hemodialysis patients.

    PubMed

    Zonnebeld, Niek; Huberts, Wouter; van Loon, Magda M; Delhaas, Tammo; Tordoir, Jan H M

    2017-03-06

    The arteriovenous fistula (AVF) is the preferred vascular access for hemodialysis patients. Unfortunately, 20-40% of all constructed AVFs fail to mature (FTM), and are therefore not usable for hemodialysis. AVF maturation importantly depends on postoperative blood volume flow. Predicting patient-specific immediate postoperative flow could therefore support surgical planning. A computational model predicting blood volume flow is available, but the effect of blood flow predictions on the clinical endpoint of maturation (at least 500 mL/min blood volume flow, diameter of the venous cannulation segment ≥4 mm) remains undetermined. A multicenter randomized clinical trial will be conducted in which 372 patients will be randomized (1:1 allocation ratio) between conventional healthcare and computational model-aided decision making. All patients are extensively examined using duplex ultrasonography (DUS) during preoperative assessment (12 venous and 11 arterial diameter measurements; 3 arterial volume flow measurements). The computational model will predict patient-specific immediate postoperative blood volume flows based on this DUS examination. Using these predictions, the preferred AVF configuration is recommended for the individual patient (radiocephalic, brachiocephalic, or brachiobasilic). The primary endpoint is FTM rate at six weeks in both groups, secondary endpoints include AVF functionality and patency rates at 6 and 12 months postoperatively. ClinicalTrials.gov (NCT02453412), and ToetsingOnline.nl (NL51610.068.14).

  4. The Combination of Micro Diaphragm Pumps and Flow Sensors for Single Stroke Based Liquid Flow Control

    PubMed Central

    Jenke, Christoph; Pallejà Rubio, Jaume; Kibler, Sebastian; Häfner, Johannes; Richter, Martin; Kutter, Christoph

    2017-01-01

    With the combination of micropumps and flow sensors, highly accurate and secure closed-loop controlled micro dosing systems for liquids are possible. Implementing a single stroke based control mode with piezoelectrically driven micro diaphragm pumps can provide a solution for dosing of volumes down to nanoliters or variable average flow rates in the range of nL/min to μL/min. However, sensor technologies feature a yet undetermined accuracy for measuring highly pulsatile micropump flow. Two miniaturizable in-line sensor types providing electrical readout—differential pressure based flow sensors and thermal calorimetric flow sensors—are evaluated for their suitability of combining them with mircopumps. Single stroke based calibration of the sensors was carried out with a new method, comparing displacement volumes and sensor flow volumes. Limitations of accuracy and performance for single stroke based flow control are described. Results showed that besides particle robustness of sensors, controlling resistive and capacitive damping are key aspects for setting up reproducible and reliable liquid dosing systems. Depending on the required average flow or defined volume, dosing systems with an accuracy of better than 5% for the differential pressure based sensor and better than 6.5% for the thermal calorimeter were achieved. PMID:28368344

  5. A multicomponent tracer field experiment to measure the flow volume, surface area, and rectilinear spacing of fractures away from the wellbore

    NASA Astrophysics Data System (ADS)

    Cathles, L. M.; Sanford, W. E.; Hawkins, A.; Li, Y. V.

    2017-12-01

    The nature of flow in fractured porous media is important to almost all subsurface processes including oil and gas recovery, contaminant transport and remediation, CO2 sequestration, and geothermal heat extraction. One would like to know, under flowing conditions, the flow volume, surface area, effective aperture, and rectilinear spacing of fractures in a representative volume of rock away from the well bore, but no methods currently allow acquisition of this data. It could, however, be collected by deploying inert tracers with a wide range of aqueous diffusion constants (e.g., rapidly diffusing heat to non-diffusing nanoparticle) in the following fashion: The flow volume is defined by the heated volume measured by resistivity surveys. The fracture volume within this flow volume is indicate by the nanoparticle transit time. The average fracture spacing is indicated by the evolving thermal profile in the monitor and the production wells (measured by fiber optic cable), and by the retention of absorbing tracers. The average fracture aperture is determined by permeability measurements and the average fracture separation. We have proposed a field test to redundantly measure these fracture parameters in the fractured Dakota Sandstone where it approaches the surface in Ft Collins, Colorado. Five 30 m deep wells (an injection, production, and 3 monitor wells) cased to 20 m are proposed. The experiments will involve at least 9 different tracers. The planned field test and its potential significance will be described.

  6. Use of body plethysmography to measure effect of bimaxillary orthognathic surgery on airway resistance and lung volumes.

    PubMed

    Rezaeetalab, Fariba; Kazemian, Mozhgan; Vaezi, Touraj; Shaban, Barratollah

    2015-12-01

    Bimaxillary orthognathic surgery can cause changes to respiration and the airways. We used body plethysmography to evaluate its effect on airway resistance and lung volumes in 20 patients with class III malocclusions (8 men and 12 women, aged 17 - 32 years). Lung volumes (forced vital capacity; forced inspiratory volume/one second; forced expiratory volume/one second: forced vital capacity; peak expiratory flow; maximum expiratory flow 25-75; maximum inspiratory flow; total lung capacity; residual volume; residual volume:total lung capacity), and airway resistance were evaluated one week before, and six months after, operation. Bimaxillary operations to correct class III malocclusions significantly increased airway resistance, residual volume, total lung capacity, and residual volume:total lung capacity. Other variables also changed after operation but not significantly so. Orthognathic operations should be done with caution in patients who have pre-existing respiratory diseases. Copyright © 2015 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  7. Glottal volume velocity waveform characteristics in subjects with and without vocal training, related to gender, sound intensity, fundamental frequency, and age.

    PubMed

    Sulter, A M; Wit, H P

    1996-11-01

    Glottal volume velocity waveform characteristics of 224 subjects, categorized in four groups according to gender and vocal training, were determined, and their relations to sound-pressure level, fundamental frequency, intra-oral pressure, and age were analyzed. Subjects phonated at three intensity conditions. The glottal volume velocity waveforms were obtained by inverse filtering the oral flow. Glottal volume velocity waveforms were parameterized with flow-based (minimum flow, ac flow, average flow, maximum flow declination rate) and time-based parameters (closed quotient, closing quotient, speed quotient), as well as with derived parameters (vocal efficiency and glottal resistance). Higher sound-pressure levels, intra-oral pressures, and flow-parameter values (ac flow, maximum flow declination rate) were observed, when compared with previous investigations. These higher values might be the result of the specific phonation tasks (stressed /ae/ vowel in a word and a sentence) or filtering processes. Few statistically significant (p < 0.01) differences in parameters were found between untrained and trained subjects [the maximum flow declination rate and the closing quotient were higher in trained women (p < 0.001), and the speed quotient was higher in trained men (p < 0.005)]. Several statistically significant parameter differences were found between men and women [minimum flow, ac flow, average flow, maximum flow declination rate, closing quotient, glottal resistance (p < 0.001), and closed quotient (p < 0.005)]. Significant effects of intensity condition were observed on ac flow, maximum flow declination rate, closing quotient, and vocal efficiency in women (p < 0.005), and on minimum flow, ac flow, average flow, maximum flow declination rate, closed quotient, and vocal efficiency in men (p < 0.01).

  8. Collective coordinates and constrained hamiltonian systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dayi, O.F.

    1992-07-01

    A general method of incorporating collective coordinates (transformation of fields into an overcomplete basis) with constrained hamiltonian systems is given where the original phase space variables and collective coordinates can be bosonic or/and fermionic. This method is illustrated by applying it to the SU(2) Yang-Mills-Higgs theory and its BFV-BRST quantization is discussed. Moreover, this formalism is used to give a systematic way of converting second class constraints into effectively first class ones, by considering second class constraints as first class constraints and gauge fixing conditions. This approach is applied to the massive superparticle. Proca lagrangian, and some topological quantum fieldmore » theories.« less

  9. The quantization of the chiral Schwinger model based on the BFT-BFV formalism II

    NASA Astrophysics Data System (ADS)

    Park, Mu-In; Park, Young-Jai; Yoon, Sean J.

    1998-12-01

    We apply an improved version of Batalin-Fradkin-Tyutin Hamiltonian method to the a = 1 chiral Schwinger model, which is much more nontrivial than the a>1 one. Furthermore, through the path integral quantization, we newly resolve the problem of the nontrivial 0954-3899/24/12/002/img6-function as well as that of the unwanted Fourier parameter 0954-3899/24/12/002/img7 in the measure. As a result, we explicitly obtain the fully gauge invariant partition function, which includes a new type of Wess-Zumino term irrelevant to the gauge symmetry as well as the usual WZ action.

  10. Classical BV Theories on Manifolds with Boundary

    NASA Astrophysics Data System (ADS)

    Cattaneo, Alberto S.; Mnev, Pavel; Reshetikhin, Nicolai

    2014-12-01

    In this paper we extend the classical BV framework to gauge theories on spacetime manifolds with boundary. In particular, we connect the BV construction in the bulk with the BFV construction on the boundary and we develop its extension to strata of higher codimension in the case of manifolds with corners. We present several examples including electrodynamics, Yang-Mills theory and topological field theories coming from the AKSZ construction, in particular, the Chern-Simons theory, the BF theory, and the Poisson sigma model. This paper is the first step towards developing the perturbative quantization of such theories on manifolds with boundary in a way consistent with gluing.

  11. The model for self-dual chiral bosons as a Hodge theory

    NASA Astrophysics Data System (ADS)

    Upadhyay, Sudhaker; Mandal, Bhabani Prasad

    2011-09-01

    We consider (1+1) dimensional theory for a single self-dual chiral boson as a classical model for gauge theory. Using the Batalin-Fradkin-Vilkovisky (BFV) technique, the nilpotent BRST and anti-BRST symmetry transformations for this theory have been studied. In this model other forms of nilpotent symmetry transformations like co-BRST and anti-co-BRST, which leave the gauge-fixing part of the action invariant, are also explored. We show that the nilpotent charges for these symmetry transformations satisfy the algebra of the de Rham cohomological operators in differential geometry. The Hodge decomposition theorem on compact manifold is also studied in the context of conserved charges.

  12. Quantization of a U(1) gauged chiral boson in the Batalin-Fradkin-Vilkovisky scheme

    NASA Astrophysics Data System (ADS)

    Ghosh, Subir

    1994-03-01

    The scheme developed by Batalin, Fradkin, and Vilkovisky (BFV) to convert a second-class constrained system to a first-class one (having gauge invariance) is used in the Floreanini-Jackiw formulation of the chiral boson interacting with a U(1) gauge field. Explicit expressions of the BRST charge, the unitarizing Hamiltonian, and the BRST invariant effective action are provided and the full quantization is carried through. The spectra in both cases have been analyzed to show the presence of the proper chiral components explicitly. In the gauged model, Wess-Zumino terms in terms of the Batalin-Fradkin fields are identified.

  13. Quantization of a U(1) gauged chiral boson in the Batalin-Fradkin-Vilkovisky scheme

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ghosh, S.

    1994-03-15

    The scheme developed by Batalin, Fradkin, and Vilkovisky (BFV) to convert a second-class constrained system to a first-class one (having gauge invariance) is used in the Floreanini-Jackiw formulation of the chiral boson interacting with a U(1) gauge field. Explicit expressions of the BRST charge, the unitarizing Hamiltonian, and the BRST invariant effective action are provided and the full quantization is carried through. The spectra in both cases have been analyzed to show the presence of the proper chiral components explicitly. In the gauged model, Wess-Zumino terms in terms of the Batalin-Fradkin fields are identified.

  14. Effect of Age-Related Human Lens Sutures Growth on Its Fluid Dynamics.

    PubMed

    Wu, Ho-Ting D; Howse, Louisa A; Vaghefi, Ehsan

    2017-12-01

    Age-related nuclear cataract is the opacification of the clear ocular lens due to oxidative damage as we age, and is the leading cause of blindness in the world. A lack of antioxidant supply to the core of ever-growing ocular lens could contribute to the cause of this condition. In this project, a computational model was developed to study the sutural fluid inflow of the aging human lens. Three different SOLIDWORKS computational fluid dynamics models of the human lens (7 years old; 28 years old; 46 years old) were created, based on available literature data. The fluid dynamics of the lens sutures were modelled using the Stokes flow equations, combined with realistic physiological boundary conditions and embedded in COMSOL Multiphysics. The flow rate, volume, and flow rate per volume of fluid entering the aging lens were examined, and all increased over the 40 years modelled. However, while the volume of the lens grew by ∼300% and the flow rate increased by ∼400%, the flow rate per volume increased only by very moderate ∼38%. Here, sutural information from humans of 7 to 46 years of age was obtained. In this modelled age range, an increase of flow rate per volume was observed, albeit at very slow rate. We hypothesize that with even further increasing age (60+ years old), the lens volume growth would outpace its flow rate increases, which would eventually lead to malnutrition of the lens nucleus and onset of cataracts.

  15. 40 CFR 86.078-3 - Abbreviations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., and for 1985 and Later Model Year New Gasoline Fueled, Natural Gas-Fueled, Liquefied Petroleum Gas... feet per hour. CFV—Critical flow venturi. CFV-CVS—Critical flow venturi—constant volume sampler... pump—constant volume sampler. ppm—parts per million by volume. ppm C—parts per million, carbon. psi...

  16. A Second Law Based Unstructured Finite Volume Procedure for Generalized Flow Simulation

    NASA Technical Reports Server (NTRS)

    Majumdar, Alok

    1998-01-01

    An unstructured finite volume procedure has been developed for steady and transient thermo-fluid dynamic analysis of fluid systems and components. The procedure is applicable for a flow network consisting of pipes and various fittings where flow is assumed to be one dimensional. It can also be used to simulate flow in a component by modeling a multi-dimensional flow using the same numerical scheme. The flow domain is discretized into a number of interconnected control volumes located arbitrarily in space. The conservation equations for each control volume account for the transport of mass, momentum and entropy from the neighboring control volumes. In addition, they also include the sources of each conserved variable and time dependent terms. The source term of entropy equation contains entropy generation due to heat transfer and fluid friction. Thermodynamic properties are computed from the equation of state of a real fluid. The system of equations is solved by a hybrid numerical method which is a combination of simultaneous Newton-Raphson and successive substitution schemes. The paper also describes the application and verification of the procedure by comparing its predictions with the analytical and numerical solution of several benchmark problems.

  17. Comparison between uroflowmetry and sonouroflowmetry in recording of urinary flow in healthy men.

    PubMed

    Krhut, Jan; Gärtner, Marcel; Sýkora, Radek; Hurtík, Petr; Burda, Michal; Luňáček, Libor; Zvarová, Katarína; Zvara, Peter

    2015-08-01

    To evaluate the accuracy of sonouroflowmetry in recording urinary flow parameters and voided volume. A total of 25 healthy male volunteers (age 18-63 years) were included in the study. All participants were asked to carry out uroflowmetry synchronous with recording of the sound generated by the urine stream hitting the water level in the urine collection receptacle, using a dedicated cell phone. From 188 recordings, 34 were excluded, because of voided volume <150 mL or technical problems during recording. Sonouroflowmetry recording was visualized in a form of a trace, representing sound intensity over time. Subsequently, the matching datasets of uroflowmetry and sonouroflowmetry were compared with respect to flow time, voided volume, maximum flow rate and average flow rate. Pearson's correlation coefficient was used to compare parameters recorded by uroflowmetry with those calculated based on sonouroflowmetry recordings. The flow pattern recorded by sonouroflowmetry showed a good correlation with the uroflowmetry trace. A strong correlation (Pearson's correlation coefficient 0.87) was documented between uroflowmetry-recorded flow time and duration of the sound signal recorded with sonouroflowmetry. A moderate correlation was observed in voided volume (Pearson's correlation coefficient 0.68) and average flow rate (Pearson's correlation coefficient 0.57). A weak correlation (Pearson's correlation coefficient 0.38) between maximum flow rate recorded using uroflowmetry and sonouroflowmetry-recorded peak sound intensity was documented. The present study shows that the basic concept utilizing sound analysis for estimation of urinary flow parameters and voided volume is valid. However, further development of this technology and standardization of recording algorithm are required. © 2015 The Japanese Urological Association.

  18. Estimating the system price of redox flow batteries for grid storage

    NASA Astrophysics Data System (ADS)

    Ha, Seungbum; Gallagher, Kevin G.

    2015-11-01

    Low-cost energy storage systems are required to support extensive deployment of intermittent renewable energy on the electricity grid. Redox flow batteries have potential advantages to meet the stringent cost target for grid applications as compared to more traditional batteries based on an enclosed architecture. However, the manufacturing process and therefore potential high-volume production price of redox flow batteries is largely unquantified. We present a comprehensive assessment of a prospective production process for aqueous all vanadium flow battery and nonaqueous lithium polysulfide flow battery. The estimated investment and variable costs are translated to fixed expenses, profit, and warranty as a function of production volume. When compared to lithium-ion batteries, redox flow batteries are estimated to exhibit lower costs of manufacture, here calculated as the unit price less materials costs, owing to their simpler reactor (cell) design, lower required area, and thus simpler manufacturing process. Redox flow batteries are also projected to achieve the majority of manufacturing scale benefits at lower production volumes as compared to lithium-ion. However, this advantage is offset due to the dramatically lower present production volume of flow batteries compared to competitive technologies such as lithium-ion.

  19. Volume of the steady-state space of financial flows in a monetary stock-flow-consistent model

    NASA Astrophysics Data System (ADS)

    Hazan, Aurélien

    2017-05-01

    We show that a steady-state stock-flow consistent macro-economic model can be represented as a Constraint Satisfaction Problem (CSP). The set of solutions is a polytope, which volume depends on the constraints applied and reveals the potential fragility of the economic circuit, with no need to study the dynamics. Several methods to compute the volume are compared, inspired by operations research methods and the analysis of metabolic networks, both exact and approximate. We also introduce a random transaction matrix, and study the particular case of linear flows with respect to money stocks.

  20. Infusion volume control and calculation using metronome and drop counter based intravenous infusion therapy helper.

    PubMed

    Park, Kyungnam; Lee, Jangyoung; Kim, Soo-Young; Kim, Jinwoo; Kim, Insoo; Choi, Seung Pill; Jeong, Sikyung; Hong, Sungyoup

    2013-06-01

    This study assessed the method of fluid infusion control using an IntraVenous Infusion Controller (IVIC). Four methods of infusion control (dial flow controller, IV set without correction, IV set with correction and IVIC correction) were used to measure the volume of each technique at two infusion rates. The infused fluid volume with a dial flow controller was significantly larger than other methods. The infused fluid volume was significantly smaller with an IV set without correction over time. Regarding the concordance correlation coefficient (CCC) of infused fluid volume in relation to a target volume, IVIC correction was shown to have the highest level of agreement. The flow rate measured in check mode showed a good agreement with the volume of collected fluid after passing through the IV system. Thus, an IVIC could assist in providing an accurate infusion control. © 2013 Wiley Publishing Asia Pty Ltd.

  1. Comparison of Diaphragmatic Breathing Exercise, Volume and Flow Incentive Spirometry, on Diaphragm Excursion and Pulmonary Function in Patients Undergoing Laparoscopic Surgery: A Randomized Controlled Trial

    PubMed Central

    Anand, R.

    2016-01-01

    Objective. To evaluate the effects of diaphragmatic breathing exercises and flow and volume-oriented incentive spirometry on pulmonary function and diaphragm excursion in patients undergoing laparoscopic abdominal surgery. Methodology. We selected 260 patients posted for laparoscopic abdominal surgery and they were block randomization as follows: 65 patients performed diaphragmatic breathing exercises, 65 patients performed flow incentive spirometry, 65 patients performed volume incentive spirometry, and 65 patients participated as a control group. All of them underwent evaluation of pulmonary function with measurement of Forced Vital Capacity (FVC), Forced Expiratory Volume in the first second (FEV1), Peak Expiratory Flow Rate (PEFR), and diaphragm excursion measurement by ultrasonography before the operation and on the first and second postoperative days. With the level of significance set at p < 0.05. Results. Pulmonary function and diaphragm excursion showed a significant decrease on the first postoperative day in all four groups (p < 0.001) but was evident more in the control group than in the experimental groups. On the second postoperative day pulmonary function (Forced Vital Capacity) and diaphragm excursion were found to be better preserved in volume incentive spirometry and diaphragmatic breathing exercise group than in the flow incentive spirometry group and the control group. Pulmonary function (Forced Vital Capacity) and diaphragm excursion showed statistically significant differences between volume incentive spirometry and diaphragmatic breathing exercise group (p < 0.05) as compared to that flow incentive spirometry group and the control group. Conclusion. Volume incentive spirometry and diaphragmatic breathing exercise can be recommended as an intervention for all patients pre- and postoperatively, over flow-oriented incentive spirometry for the generation and sustenance of pulmonary function and diaphragm excursion in the management of laparoscopic abdominal surgery. PMID:27525116

  2. Comparison of Diaphragmatic Breathing Exercise, Volume and Flow Incentive Spirometry, on Diaphragm Excursion and Pulmonary Function in Patients Undergoing Laparoscopic Surgery: A Randomized Controlled Trial.

    PubMed

    Alaparthi, Gopala Krishna; Augustine, Alfred Joseph; Anand, R; Mahale, Ajith

    2016-01-01

    Objective. To evaluate the effects of diaphragmatic breathing exercises and flow and volume-oriented incentive spirometry on pulmonary function and diaphragm excursion in patients undergoing laparoscopic abdominal surgery. Methodology. We selected 260 patients posted for laparoscopic abdominal surgery and they were block randomization as follows: 65 patients performed diaphragmatic breathing exercises, 65 patients performed flow incentive spirometry, 65 patients performed volume incentive spirometry, and 65 patients participated as a control group. All of them underwent evaluation of pulmonary function with measurement of Forced Vital Capacity (FVC), Forced Expiratory Volume in the first second (FEV1), Peak Expiratory Flow Rate (PEFR), and diaphragm excursion measurement by ultrasonography before the operation and on the first and second postoperative days. With the level of significance set at p < 0.05. Results. Pulmonary function and diaphragm excursion showed a significant decrease on the first postoperative day in all four groups (p < 0.001) but was evident more in the control group than in the experimental groups. On the second postoperative day pulmonary function (Forced Vital Capacity) and diaphragm excursion were found to be better preserved in volume incentive spirometry and diaphragmatic breathing exercise group than in the flow incentive spirometry group and the control group. Pulmonary function (Forced Vital Capacity) and diaphragm excursion showed statistically significant differences between volume incentive spirometry and diaphragmatic breathing exercise group (p < 0.05) as compared to that flow incentive spirometry group and the control group. Conclusion. Volume incentive spirometry and diaphragmatic breathing exercise can be recommended as an intervention for all patients pre- and postoperatively, over flow-oriented incentive spirometry for the generation and sustenance of pulmonary function and diaphragm excursion in the management of laparoscopic abdominal surgery.

  3. Slip-Flow and Heat Transfer of a Non-Newtonian Nanofluid in a Microtube

    PubMed Central

    Niu, Jun; Fu, Ceji; Tan, Wenchang

    2012-01-01

    The slip-flow and heat transfer of a non-Newtonian nanofluid in a microtube is theoretically studied. The power-law rheology is adopted to describe the non-Newtonian characteristics of the flow, in which the fluid consistency coefficient and the flow behavior index depend on the nanoparticle volume fraction. The velocity profile, volumetric flow rate and local Nusselt number are calculated for different values of nanoparticle volume fraction and slip length. The results show that the influence of nanoparticle volume fraction on the flow of the nanofluid depends on the pressure gradient, which is quite different from that of the Newtonian nanofluid. Increase of the nanoparticle volume fraction has the effect to impede the flow at a small pressure gradient, but it changes to facilitate the flow when the pressure gradient is large enough. This remarkable phenomenon is observed when the tube radius shrinks to micrometer scale. On the other hand, we find that increase of the slip length always results in larger flow rate of the nanofluid. Furthermore, the heat transfer rate of the nanofluid in the microtube can be enhanced due to the non-Newtonian rheology and slip boundary effects. The thermally fully developed heat transfer rate under constant wall temperature and constant heat flux boundary conditions is also compared. PMID:22615961

  4. An estimation of intracranial blood flow in the new-born infant.

    PubMed Central

    Cross, K W; Dear, P R; Hathorn, M K; Hyams, A; Kerslake, D M; Milligan, D W; Rahilly, P M; Stothers, J K

    1979-01-01

    1. A non-invasive method for the estimation of the intracranial blood flow of the new-born infant is described, and results obtained with it are presented. 2. The technique is a novel application of the principle of blood flow measurement by venous occlusion plethysmography. It is possible to apply a plethysmographic technique to the neonatal cranium because the presence of open sutures between the component bones permits small, but readily measurable, changes in intracranial volume to occur. 3. Skull volume changes are calculated from changes in the occipito-frontal circumference of the cranium as recorded and measured with a mercury-in-Silastic strain gauge. 4. The jugular veins in the baby's neck are occluded by finger pressure and there follows an increase in skull volume, which is rapid at first, but which decreases exponentially as venous drainage diverts to non-occluded channels such as the vertebral venous plexus. At the instant of jugular occlusion the rate of skull volume increase is representative of the rate of flow in the jugular vessels prior to occlusion, and so provides an index of the relative magnitude of the intracranial blood flow. The method thus allows changes in intracranial blood flow to be followed. When occlusion is released cranial volume decreases, initially rapidly, but slowing exponentially as resting volume is regained. 5. A theoretical model of the events occurring during the inflow and outflow phases has been developed, and a formula derived which allows an estimation to be made of the flow of blood through uncompressed channels. The measured value of jugular blood flow can then be augmented to an estimate of total intracranial flow. 6. The mean cerebral blood flow of sixteen normal babies was estimated to be 40 ml. 100 g-1.min-1 (S.D. = +/- 11.63). Images Fig. 2 Fig. 6 PMID:458665

  5. Xerostomia, salivary characteristics and gland volumes following intensity-modulated radiotherapy for nasopharyngeal carcinoma: a two-year follow up.

    PubMed

    Sim, Cpc; Soong, Y L; Pang, Epp; Lim, C; Walker, G D; Manton, D J; Reynolds, E C; Wee, Jts

    2018-06-01

    To evaluate changes in xerostomia status, salivary characteristics and gland volumes 2 years following radiotherapy in nasopharyngeal carcinoma patients. Xerostomia scores, salivary flow rates, pH and buffering capacity were measured at pre-radiotherapy, mid-radiotherapy, 2 weeks, 3 months and 2 years post-radiotherapy. Salivary gland volumes and their correlation with radiation dose were also assessed. Mean radiation dose to oral cavity, parotid and submandibular glands (SMG) was 44.5, 65.0 and 38.6 Gy respectively. Parotid and SMG volumes decreased 33% at 3 months post-radiotherapy; volumes at 2 years post-radiotherapy were 84% and 51% of pre-radiotherapy levels, respectively. Correlations were observed between parotid gland volume per cent reduction and its radiation dose and between resting salivary flow rate reduction and post-radiotherapy/pre-radiotherapy SMG volume ratio. Salivary flow rates and resting saliva pH remained significantly low at 2 years post-radiotherapy (both flow rates, P = 0.001; resting saliva pH, P = 0.005). Similarly, xerostomia scores remained significantly higher compared with pre-radiotherapy levels. Submandibular gland volumetric shrinkage persisted 2 years after radiotherapy. Xerostomia scores remained significantly higher, and salivary flow rates and resting saliva pH remained significantly lower, suggesting that study participants were still at risk for hyposalivation-related oral diseases. © 2018 Australian Dental Association.

  6. Spatial Convergence of Three Dimensional Turbulent Flows

    NASA Technical Reports Server (NTRS)

    Park, Michael A.; Anderson, W. Kyle

    2016-01-01

    Finite-volume and finite-element schemes, both implemented within the FUN3D flow solver, are evaluated for several test cases described on the Turbulence-Modeling Resource (TMR) web site. The cases include subsonic flow over a hemisphere cylinder, subsonic flow over a swept bump configuration, and supersonic flow in a square duct. The finite- volume and finite-element schemes are both used to obtain solutions for the first two cases, whereas only the finite-volume scheme is used for the supersonic duct. For the hemisphere cylinder, finite-element solutions obtained on tetrahedral meshes are compared with finite- volume solutions on mixed-element meshes. For the swept bump, finite-volume solutions have been obtained for both hexahedral and tetrahedral meshes and are compared with finite-element solutions obtained on tetrahedral meshes. For the hemisphere cylinder and the swept bump, solutions are obtained on a series of meshes with varying grid density and comparisons are made between drag coefficients, pressure distributions, velocity profiles, and profiles of the turbulence working variable. The square duct shows small variation due to element type or the spatial accuracy of turbulence model convection. It is demonstrated that the finite-element scheme on tetrahedral meshes yields similar accuracy as the finite- volume scheme on mixed-element and hexahedral grids, and demonstrates less sensitivity to the mesh topology (biased tetrahedral grids) than the finite-volume scheme.

  7. Transpiring purging access probe for particulate laden or hazardous environments

    DOEpatents

    VanOsdol, John G

    2013-12-03

    An access probe for remote-sensing access through a viewing port, viewing volume, and access port into a vessel. The physical boundary around the viewing volume is partially formed by a porous sleeve lying between the viewing volume and a fluid conduit. In a first mode of operation, a fluid supplied to the fluid conduit encounters the porous sleeve and flows through the porous material to maintain the viewing volume free of ash or other matter. When additional fluid force is needed to clear the viewing volume, the pressure of the fluid flow is increased sufficiently to slidably translate the porous sleeve, greatly increasing the flow into the viewing volume. The porous sleeve is returned to position by an actuating spring. The access probe thereby provides for alternate modes of operation based on the pressure of an actuating fluid.

  8. Determinants of expiratory flow limitation in healthy women during exercise.

    PubMed

    Dominelli, Paolo B; Guenette, Jordan A; Wilkie, Sabrina S; Foster, Glen E; Sheel, A William

    2011-09-01

    Expiratory flow limitation (EFL) can occur in healthy young women during exercise. We questioned whether the occurrence and severity of EFL were related to aerobic fitness or anatomical factors. Twenty-two healthy young (<40 yr) women performed a progressive cycle test to exhaustion. The subjects' maximum expiratory flow-volume curve was compiled from several effort-graded vital capacity maneuvers before and after exercise. The maximum expiratory flow-volume curve, along with inspiratory capacity maneuvers, was used to determine lung volumes and expiratory flows and to quantify EFL. To determine relative airway size, we used a ratio sensitive to both airway size and lung volume, called the dysanapsis ratio. The subjects were partitioned into two groups based upon the appearance of >5% EFL. Ten subjects showed EFL during exercise. Forced vital capacities (4.4 ± 0.4 vs 3.7 ± 0.4 L, P < 0.001) and forced expiratory flows for any given lung volume were significantly larger in the non-expiratory flow-limited (NEFL) group. The NEFL group's dysanapsis ratio was significantly larger than that of the EFL group (0.27 ± 0.06 vs 0.21 ± 0.04, respectively, P < 0.05), indicating larger airways in the NEFL group. There was no difference between the NEFL and EFL groups with respect to maximal aerobic capacity (50.8 ± 10.0 vs 46.7 ± 5.9 mL·kg(-1)·min(-1), respectively, P = 0.264). At peak exercise, the NEFL group had a significantly higher end-expiratory lung volume than the EFL group (40.1% ± 4.8% vs 33.7% ± 5.7% FVC, respectively, P < 0.05). We conclude that EFL in women can largely be explained by anatomical factors that influence the capacity to generate flow and volume during exercise rather than fitness per se.

  9. Low current plasmatron fuel converter having enlarged volume discharges

    DOEpatents

    Rabinovich, Alexander; Alexeev, Nikolai; Bromberg, Leslie; Cohn, Daniel R.; Samokhin, Andrei

    2005-04-19

    A novel apparatus and method is disclosed for a plasmatron fuel converter (""plasmatron"") that efficiently uses electrical energy to produce hydrogen rich gas. The volume and shape of the plasma discharge is controlled by a fluid flow established in a plasma discharge volume. A plasmatron according to this invention produces a substantially large effective plasma discharge volume allowing for substantially greater volumetric efficiency in the initiation of chemical reactions within a volume of bulk fluid reactant flowing through the plasmatron.

  10. Low current plasmatron fuel converter having enlarged volume discharges

    DOEpatents

    Rabinovich, Alexander [Swampscott, MA; Alexeev, Nikolai [Moscow, RU; Bromberg, Leslie [Sharon, MA; Cohn, Daniel R [Chestnut Hill, MA; Samokhin, Andrei [Moscow, RU

    2009-10-06

    A novel apparatus and method is disclosed for a plasmatron fuel converter ("plasmatron") that efficiently uses electrical energy to produce hydrogen rich gas. The volume and shape of the plasma discharge is controlled by a fluid flow established in a plasma discharge volume. A plasmatron according to this invention produces a substantially large effective plasma discharge volume allowing for substantially greater volumetric efficiency in the initiation of chemical reactions within a volume of bulk fluid reactant flowing through the plasmatron.

  11. Finite-volume method with lattice Boltzmann flux scheme for incompressible porous media flow at the representative-elementary-volume scale.

    PubMed

    Hu, Yang; Li, Decai; Shu, Shi; Niu, Xiaodong

    2016-02-01

    Based on the Darcy-Brinkman-Forchheimer equation, a finite-volume computational model with lattice Boltzmann flux scheme is proposed for incompressible porous media flow in this paper. The fluxes across the cell interface are calculated by reconstructing the local solution of the generalized lattice Boltzmann equation for porous media flow. The time-scaled midpoint integration rule is adopted to discretize the governing equation, which makes the time step become limited by the Courant-Friedricks-Lewy condition. The force term which evaluates the effect of the porous medium is added to the discretized governing equation directly. The numerical simulations of the steady Poiseuille flow, the unsteady Womersley flow, the circular Couette flow, and the lid-driven flow are carried out to verify the present computational model. The obtained results show good agreement with the analytical, finite-difference, and/or previously published solutions.

  12. Characterization of swallow modulation in response to bolus volume in healthy subjects accounting for catheter diameter.

    PubMed

    Ferris, Lara; Schar, Mistyka; McCall, Lisa; Doeltgen, Sebastian; Scholten, Ingrid; Rommel, Nathalie; Cock, Charles; Omari, Taher

    2018-06-01

    Characterization of the pharyngeal swallow response to volume challenges is important for swallowing function assessment. The diameter of the pressure-impedance recording catheter may influence these results. In this study, we captured key physiological swallow measures in response to bolus volume utilizing recordings acquired by two catheters of different diameter. Ten healthy adults underwent repeat investigations with 8- and 10-Fr catheters. Liquid bolus swallows of volumes 2.5, 5, 10, 20, and 30 mL were recorded. Measures indicative of distension, contractility, and flow timing were assessed. Pressure-impedance recordings with pressure-flow analysis were used to capture key distension, contractility, and pressure-flow timing parameters. Larger bolus volumes increased upper esophageal sphincter distension diameter (P < .001) and distension pressures within the hypopharynx and upper esophageal sphincter (P < .05). Bolus flow timing measures were longer, particularly latency of bolus propulsion ahead of the pharyngeal stripping wave (P < .001). Use of a larger-diameter catheter produced higher occlusive pressures, namely upper esophageal sphincter basal pressure (P < .005) and upper esophageal sphincter postdeglutitive pressure peak (P < .001). The bolus volume swallowed changed measurements indicative of distension pressure, luminal diameter, and pressure-flow timing; this is physiologically consistent with swallow modulation to accommodate larger, faster-flowing boluses. Additionally, catheter diameter predominantly affects lumen occlusive pressures. Appropriate physiological interpretation of the pressure-impedance recordings of pharyngeal swallowing requires consideration of the effects of volume and catheter diameter. NA. Laryngoscope, 128:1328-1334, 2018. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  13. Biomedical Effects of Chemical-Threat-Agent Antidote and Pretreatment Drugs. An Abstracted Bibliography. Volume 1.

    DTIC Science & Technology

    1986-04-01

    Adams, R., Venna, P., Jackson, A., and Miller, R. TITLE: Plasma pharmacokinetics of intravenously administered atropine in normal human subjects Journal...atropine by i.v. route and inhalation. Measurements of respiratory airway resistance, N2 closing volume, maximal expiratory flow volume, pressure volume...maximum flow -static recoil and esophageal elasticity were compared to non-atropinized values. FINDINGS: "I.V. administration produced a marked

  14. Unsteady force estimation using a Lagrangian drift-volume approach

    NASA Astrophysics Data System (ADS)

    McPhaden, Cameron J.; Rival, David E.

    2018-04-01

    A novel Lagrangian force estimation technique for unsteady fluid flows has been developed, using the concept of a Darwinian drift volume to measure unsteady forces on accelerating bodies. The construct of added mass in viscous flows, calculated from a series of drift volumes, is used to calculate the reaction force on an accelerating circular flat plate, containing highly-separated, vortical flow. The net displacement of fluid contained within the drift volumes is, through Darwin's drift-volume added-mass proposition, equal to the added mass of the plate and provides the reaction force of the fluid on the body. The resultant unsteady force estimates from the proposed technique are shown to align with the measured drag force associated with a rapid acceleration. The critical aspects of understanding unsteady flows, relating to peak and time-resolved forces, often lie within the acceleration phase of the motions, which are well-captured by the drift-volume approach. Therefore, this Lagrangian added-mass estimation technique opens the door to fluid-dynamic analyses in areas that, until now, were inaccessible by conventional means.

  15. [Effects of breathing exercises on breathing pattern and thoracoabdominal motion after gastroplasty].

    PubMed

    Tomich, Georgia Miranda; França, Danielle Corrêa; Diniz, Marco Túlio Costa; Britto, Raquel Rodrigues; Sampaio, Rosana Ferreira; Parreira, Verônica Franco

    2010-01-01

    To evaluate breathing pattern and thoracoabdominal motion during breathing exercises. Twenty-four patients with class II or III obesity (18 women; 6 men) were studied on the second postoperative day after gastroplasty. The mean age was 37 +/- 11 years, and the mean BMI was 44 +/- 3 kg/m(2). Diaphragmatic breathing, incentive spirometry with a flow-oriented device and incentive spirometry with a volume-oriented device were performed in random order. Respiratory inductive plethysmography was used in order to measure respiratory variables and thoracoabdominal motion. Comparisons among the three exercises showed significant differences: tidal volume was higher during incentive spirometry (with the flow-oriented device or with the volume-oriented device) than during diaphragmatic breathing; the respiratory rate was lower during incentive spirometry with the volume-oriented device than during incentive spirometry with the flow-oriented device; and minute ventilation was higher during incentive spirometry (with the flow-oriented device or with the volume-oriented device) than during diaphragmatic breathing. Rib cage motion did not vary during breathing exercises, although there was an increase in thoracoabdominal asynchrony, especially during incentive spirometry with the flow-oriented device. Among the breathing exercises evaluated, incentive spirometry with the volume-oriented device provided the best results, because it allowed slower, deeper inhalation.

  16. Control volume based hydrocephalus research; a phantom study

    NASA Astrophysics Data System (ADS)

    Cohen, Benjamin; Voorhees, Abram; Madsen, Joseph; Wei, Timothy

    2009-11-01

    Hydrocephalus is a complex spectrum of neurophysiological disorders involving perturbation of the intracranial contents; primarily increased intraventricular cerebrospinal fluid (CSF) volume and intracranial pressure are observed. CSF dynamics are highly coupled to the cerebral blood flows and pressures as well as the mechanical properties of the brain. Hydrocephalus, as such, is a very complex biological problem. We propose integral control volume analysis as a method of tracking these important interactions using mass and momentum conservation principles. As a first step in applying this methodology in humans, an in vitro phantom is used as a simplified model of the intracranial space. The phantom's design consists of a rigid container filled with a compressible gel. Within the gel a hollow spherical cavity represents the ventricular system and a cylindrical passage represents the spinal canal. A computer controlled piston pump supplies sinusoidal volume fluctuations into and out of the flow phantom. MRI is used to measure fluid velocity and volume change as functions of time. Independent pressure measurements and momentum flow rate measurements are used to calibrate the MRI data. These data are used as a framework for future work with live patients and normal individuals. Flow and pressure measurements on the flow phantom will be presented through the control volume framework.

  17. Erosion and deposition on a debris-flow fan

    NASA Astrophysics Data System (ADS)

    Densmore, A. L.; Schuerch, P.; Rosser, N. J.; McArdell, B. W.

    2011-12-01

    The ability of a debris flow to entrain or deposit sediment controls the downstream evolution of flow volume, and ultimately dictates both the geomorphic impact of the flow and the potential hazard that it represents. Our understanding of the patterns of, and controls on, such flow volume changes remains extremely limited, however, partly due to a poor mechanistic grasp of the interactions between debris flows and their bed and banks. In addition, we lack a good understanding of the cumulative long-term effects of sequences of flows in a single catchment-fan system. Here we begin to address these issues by using repeated terrestrial laser scanning (TLS) to characterize the detailed surface change associated with the passage of multiple debris flows on the Illgraben fan, Switzerland. We calculate surface elevation change along a 300 m study reach, and from this derive the downfan rate of flow volume change, or lag rate; for comparison, we also derive the spatially-averaged lag rate over the entire ~2 km length of the fan. Lag rates are broadly comparable over both length scales, indicating that flow behavior does not vary significantly across the fan for most flows, but importantly we find that flow volume at the fan head is a poor predictor of volume at the fan toe. The sign and magnitude of bed elevation change scale with local flow depth; at flow depths < 2 m, erosion and deposition are approximately equally likely, but erosion becomes increasingly dominant for flow depths > 2 m. On the Illgraben fan, this depth corresponds to a basal shear stress of 3-4 kPa. Because flow depth is in part a function of channel cross-sectional topography, which varies strongly both within and between flows, this result indicates that erosion and deposition are likely to be highly dynamic. The dependence of flow volume change on both the channel topography and the flow history may thus complicate efforts to predict debris-flow inundation areas by simple flow routing. We then apply a 2d numerical model of debris-flow fan evolution to explore the key controls on debris-flow routing and topographic development over sequences of multiple flows. We find that fan topographic roughness plays an important role in both channel development and fan surface stability. We also find that, while first-order fan shape is largely insensitive to the input flow sequence, second-order variables such as the pattern of surface exposure ages and the distribution of channel characteristics hold more promise as robust recorders of past flow conditions. Further work is needed to understand the degree to which the TLS-derived (and Illgraben-specific) relationship between bed elevation change and flow depth can be applied in different settings, and to elucidate the role played by coarse debris in controlling patterns of erosion and deposition.

  18. 40 CFR 90.421 - Dilute gaseous exhaust sampling and analytical system description.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Volume Sampler (PDP-CVS) system with a heat exchanger, or a Critical Flow Venturi—Constant Volume Sampler (CFV-CVS) system with CFV sample probes and/or a heat exchanger or electronic flow compensation. Figure... sampling point. (ii) For the CFV-CVS, either a heat exchanger or electronic flow compensation is required...

  19. 40 CFR 91.421 - Dilute gaseous exhaust sampling and analytical system description.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Pump—Constant Volume Sampler (PDP-CVS) system with a heat exchanger, or a Critical Flow Venturi—Constant Volume Sampler (CFV-CVS) system with CVS sample probes and/or a heat exchanger or electronic flow... sampling point. (ii) For the CFV-CVS, either a heat exchanger or electronic flow compensation is required...

  20. 40 CFR 91.421 - Dilute gaseous exhaust sampling and analytical system description.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Pump—Constant Volume Sampler (PDP-CVS) system with a heat exchanger, or a Critical Flow Venturi—Constant Volume Sampler (CFV-CVS) system with CVS sample probes and/or a heat exchanger or electronic flow... sampling point. (ii) For the CFV-CVS, either a heat exchanger or electronic flow compensation is required...

  1. 40 CFR 90.421 - Dilute gaseous exhaust sampling and analytical system description.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Volume Sampler (PDP-CVS) system with a heat exchanger, or a Critical Flow Venturi—Constant Volume Sampler (CFV-CVS) system with CFV sample probes and/or a heat exchanger or electronic flow compensation. Figure... sampling point. (ii) For the CFV-CVS, either a heat exchanger or electronic flow compensation is required...

  2. 40 CFR 91.421 - Dilute gaseous exhaust sampling and analytical system description.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Pump—Constant Volume Sampler (PDP-CVS) system with a heat exchanger, or a Critical Flow Venturi—Constant Volume Sampler (CFV-CVS) system with CVS sample probes and/or a heat exchanger or electronic flow... sampling point. (ii) For the CFV-CVS, either a heat exchanger or electronic flow compensation is required...

  3. 40 CFR 90.421 - Dilute gaseous exhaust sampling and analytical system description.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Volume Sampler (PDP-CVS) system with a heat exchanger, or a Critical Flow Venturi—Constant Volume Sampler (CFV-CVS) system with CFV sample probes and/or a heat exchanger or electronic flow compensation. Figure... sampling point. (ii) For the CFV-CVS, either a heat exchanger or electronic flow compensation is required...

  4. Fluidic Oscillator Having Decoupled Frequency and Amplitude Control

    NASA Technical Reports Server (NTRS)

    Koklu, Mehti (Inventor)

    2017-01-01

    A fluidic oscillator having independent frequency and amplitude control includes a fluidic-oscillator main flow channel having a main flow inlet, a main flow outlet, and first and second control ports disposed at opposing sides thereof. A fluidic-oscillator controller has an inlet and outlet. A volume defined by the main flow channel is greater than the volume defined by the controller. A flow diverter coupled to the outlet of the controller defines a first fluid flow path from the controller's outlet to the first control port and defines a second fluid flow path from the controller's outlet to the second control port.

  5. Fluidic Oscillator Having Decoupled Frequency and Amplitude Control

    NASA Technical Reports Server (NTRS)

    Koklu, Mehti (Inventor)

    2016-01-01

    A fluidic oscillator having independent frequency and amplitude control includes a fluidic-oscillator main flow channel having a main flow inlet, a main flow outlet, and first and second control ports disposed at opposing sides thereof. A fluidic-oscillator controller has an inlet and outlet. A volume defined by the main flow channel is greater than the volume defined by the controller. A flow diverter coupled to the outlet of the controller defines a first fluid flow path from the controller's outlet to the first control port and defines a second fluid flow path from the controller's outlet to the second control port.

  6. Evaluation of extracranial blood flow in Parkinson disease.

    PubMed

    Haktanir, Alpay; Yaman, Mehmet; Acar, Murat; Gecici, Omer; Demirel, Reha; Albayrak, Ramazan; Demirkirkan, Kemal

    2006-01-02

    Decreased cerebral flow velocities in Parkinsonian patients were reported previously. Because of the limited data on vascular changes in Parkinson disease (PD), which may have a vascular etiology, we aimed to disclose any possible cerebral hemodynamic alteration in Parkinsonian patients. We prospectively evaluated 28 non-demented, idiopathic parkinsonian patients and 19 age and sex matched controls with Doppler sonography. Flow volumes, peak systolic flow velocities, and cross-sectional areas of vertebral and internal carotid arteries (ICA) were measured and compared between patients and controls. Correlation of patient age and disease duration with Doppler parameters was observed; and each Doppler parameter of patients within each Hoehn-Yahr scale was compared. There was no significant difference of measured parameters between groups. No correlation was found between disease duration and age with flow volume, cross-sectional area or peak systolic velocity. Hoehn-Yahr scale was not found having significant relation with Doppler parameters. Values of vertebral, internal carotid and cerebral blood flow volumes (CBF), peak systolic velocities, and cross-sectional areas were not significantly different between Parkinsonian patients and age and sex matched controls. Although regional blood flow decreases may be seen as reported previously, Parkinson disease is not associated with a flow volume or velocity alteration of extracranial cerebral arteries.

  7. Inspiratory flow rate, not type of incentive spirometry device, influences chest wall motion in healthy individuals.

    PubMed

    Chang, Angela T; Palmer, Kerry R; McNaught, Jessie; Thomas, Peter J

    2010-08-01

    This study investigated the effect of flow rates and spirometer type on chest wall motion in healthy individuals. Twenty-one healthy volunteers completed breathing trials to either two times tidal volume (2xV(T)) or inspiratory capacity (IC) at high, low, or natural flow rates, using a volume- or flow-oriented spirometer. The proportions of rib cage movement to tidal volume (%RC/V(T)), chest wall diameters, and perceived level of exertion (RPE) were compared. Low and natural flow rates resulted in significantly lower %RC/V(T) compared to high flow rate trials (p=0.001) at 2xV(T). Low flow trials also resulted in significantly less chest wall motion in the upper anteroposterior direction than high and natural flow rates (p<0.001). At IC, significantly greater movement occurred in the abdominal lateral direction during low flow compared to high and natural flow trials (both p<0.003). RPE was lower for the low flow trials compared to high flow trials at IC and 2xV(T) (p<0.01). In healthy individuals, inspiratory flow (not device type) during incentive spirometry determines the resultant breathing pattern. High flow rates result in greater chest wall motion than low flow rates.

  8. Flow rate measurement in a volume

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Galvez, Cristhian

    A system for measuring flow rate within a volume includes one or more transmission devices that transmit one or more signals through fluid contained within the volume. The volume may be bounded, at least in part, by an outer structure and by an object at least partially contained within the outer structure. A transmission device located at a first location of the outer structure transmits a first signal to a second location of the outer structure. A second signal is transmitted through the fluid from the second location to a third location of the outer structure. The flow rate ofmore » the fluid within the volume may be determined based, at least in part, on the time of flight of both the first signal and the second signal.« less

  9. Estimated probabilities, volumes, and inundation areas depths of potential postwildfire debris flows from Carbonate, Slate, Raspberry, and Milton Creeks, near Marble, Gunnison County, Colorado

    USGS Publications Warehouse

    Stevens, Michael R.; Flynn, Jennifer L.; Stephens, Verlin C.; Verdin, Kristine L.

    2011-01-01

    During 2009, the U.S. Geological Survey, in cooperation with Gunnison County, initiated a study to estimate the potential for postwildfire debris flows to occur in the drainage basins occupied by Carbonate, Slate, Raspberry, and Milton Creeks near Marble, Colorado. Currently (2010), these drainage basins are unburned but could be burned by a future wildfire. Empirical models derived from statistical evaluation of data collected from recently burned basins throughout the intermountain western United States were used to estimate the probability of postwildfire debris-flow occurrence and debris-flow volumes for drainage basins occupied by Carbonate, Slate, Raspberry, and Milton Creeks near Marble. Data for the postwildfire debris-flow models included drainage basin area; area burned and burn severity; percentage of burned area; soil properties; rainfall total and intensity for the 5- and 25-year-recurrence, 1-hour-duration-rainfall; and topographic and soil property characteristics of the drainage basins occupied by the four creeks. A quasi-two-dimensional floodplain computer model (FLO-2D) was used to estimate the spatial distribution and the maximum instantaneous depth of the postwildfire debris-flow material during debris flow on the existing debris-flow fans that issue from the outlets of the four major drainage basins. The postwildfire debris-flow probabilities at the outlet of each drainage basin range from 1 to 19 percent for the 5-year-recurrence, 1-hour-duration rainfall, and from 3 to 35 percent for 25-year-recurrence, 1-hour-duration rainfall. The largest probabilities for postwildfire debris flow are estimated for Raspberry Creek (19 and 35 percent), whereas estimated debris-flow probabilities for the three other creeks range from 1 to 6 percent. The estimated postwildfire debris-flow volumes at the outlet of each creek range from 7,500 to 101,000 cubic meters for the 5-year-recurrence, 1-hour-duration rainfall, and from 9,400 to 126,000 cubic meters for the 25-year-recurrence, 1-hour-duration rainfall. The largest postwildfire debris-flow volumes were estimated for Carbonate Creek and Milton Creek drainage basins, for both the 5- and 25-year-recurrence, 1-hour-duration rainfalls. Results from FLO-2D modeling of the 5-year and 25-year recurrence, 1-hour rainfalls indicate that the debris flows from the four drainage basins would reach or nearly reach the Crystal River. The model estimates maximum instantaneous depths of debris-flow material during postwildfire debris flows that exceeded 5 meters in some areas, but the differences in model results between the 5-year and 25-year recurrence, 1-hour rainfalls are small. Existing stream channels or topographic flow paths likely control the distribution of debris-flow material, and the difference in estimated debris-flow volume (about 25 percent more volume for the 25-year-recurrence, 1-hour-duration rainfall compared to the 5-year-recurrence, 1-hour-duration rainfall) does not seem to substantially affect the estimated spatial distribution of debris-flow material. Historically, the Marble area has experienced periodic debris flows in the absence of wildfire. This report estimates the probability and volume of debris flow and maximum instantaneous inundation area depths after hypothetical wildfire and rainfall. This postwildfire debris-flow report does not address the current (2010) prewildfire debris-flow hazards that exist near Marble.

  10. Solar receiver protection means and method for loss of coolant flow

    DOEpatents

    Glasgow, L.E.

    1980-11-24

    An apparatus and method are disclosed for preventing a solar receiver utilizing a flowing coolant liquid for removing heat energy therefrom from overheating after a loss of coolant flow. Solar energy is directed to the solar receiver by a plurality of reflectors which rotate so that they direct solar energy to the receiver as the earth rotates. The apparatus disclosed includes a first storage tank for containing a first predetermined volume of the coolant and a first predetermined volume of gas at a first predetermined pressure. The first storage tank includes an inlet and outlet through which the coolant can enter and exit. The apparatus also includes a second storage tank for containing a second predetermined volume of the coolant and a second predetermined volume of the gas at a second predetermined pressure, the second storage tank having an inlet through which the coolant can enter. The first and second storage tanks are in fluid communication with each other through the solar receiver. The first and second predetermined coolant volumes, the first and second gas volumes, and the first and second predetermined pressures are chosen so that a predetermined volume of the coolant liquid at a predetermined rate profile will flow from the first storage tank through the solar receiver and into the second storage tank. Thus, in the event of a power failure so that coolant flow ceases and the solar reflectors stop rotating, a flow rate maintained by the pressure differential between the first and second storage tanks will be sufficient to maintain the coolant in the receiver below a predetermined upper temperature until the solar reflectors become defocused with respect to the solar receiver due to the earth's rotation.

  11. Real-time display of flow-pressure-volume loops.

    PubMed

    Morozoff, P E; Evans, R W

    1992-01-01

    Graphic display of respiratory waveforms can be valuable for monitoring the progress of ventilated patients. A system has been developed that can display flow-pressure-volume loops as derived from a patient's respiratory circuit in real time. It can also display, store, print, and retrieve ventilatory waveforms. Five loops can be displayed at once: current, previous, reference, "ideal," and previously saved. Two components, the data-display device (DDD) and the data-collection device (DCD), comprise the system. An IBM 286/386 computer with a graphics card (VGA) and bidirectional parallel port is used for the DDD; an eight-bit microprocessor card and an A/D convertor card make up the DCD. A real-time multitasking operating system was written to control the DDD, while the DCD operates from in-line assembly code. The DCD samples the pressure and flow sensors at 100 Hz and looks for a complete flow waveform pattern based on flow slope. These waveforms are then passed to the DDD via the mutual parallel port. Within the DDD a process integrates the flow to create a volume signal and performs a multilinear regression on the pressure, flow, and volume data to calculate the elastance, resistance, pressure offset, and coefficient of determination. Elastance, resistance, and offset are used to calculate Pr and Pc where: Pr[k] = P[k]-offset-(elastance.V[k]) and Pc[k] = P[k]-offset-(resistance.F[k]). Volume vs. Pc and flow vs. Pr can be displayed in real time. Patient data from previous clinical tests were loaded into the device to verify the software calculations. An analog waveform generator was used to simulate flow and pressure waveforms that validated the system.(ABSTRACT TRUNCATED AT 250 WORDS)

  12. Impacts of logging on storm peak flows, flow volumes and suspended sediment loads in Caspar Creek, California

    Treesearch

    Jack Lewis; Sylvia R. Mori; Elizabeth T. Keppeler; Robert R. Ziemer

    2001-01-01

    Abstract - Models are fit to 11 years of storm peak flows, flow volumes, and suspended sediment loads on a network of 14 stream gaging stations in the North Fork Caspar Creek, a 473-ha coastal watershed bearing a second-growth forest of redwood and Douglas-fir. For the first 4 years of monitoring, the watershed was in a relatively undisturbed state, having last been...

  13. Apparatus for passive removal of subsurface contaminants and volume flow measurement

    DOEpatents

    Jackson, Dennis G.; Rossabi, Joseph; Riha, Brian D.

    2002-01-01

    A system for improving the Baroball valve and a method for retrofitting an existing Baroball valve. This invention improves upon the Baroball valve by reshaping the interior chamber of the valve to form a flow meter measuring chamber. The Baroball valve sealing mechanism acts as a rotameter bob for determining volume flow rate through the Baroball valve. A method for retrofitting a Baroball valve includes providing static pressure ports and connecting a measuring device, to these ports, for measuring the pressure differential between the Baroball chamber and the well. A standard curve of nominal device measurements allows the volume flow rate to be determined through the retrofitted Baroball valve.

  14. Age, gender, and voided volume dependency of peak urinary flow rate and uroflowmetry nomogram in the Indian population

    PubMed Central

    Kumar, Vikash; Dhabalia, Jayesh V.; Nelivigi, Girish G.; Punia, Mahendra S.; Suryavanshi, Manav

    2009-01-01

    Objectives: The objective of this study was measurement of urine flow parameters by a non invasive urodynamic test. Variation of flow rates based on voided volume, age, and gender are described. Different nomograms are available for different populations and racial differences of urethral physiology are described. Currently, there has been no study from the Indian population on uroflow parameters. So the purpose of this study was to establish normal reference ranges of maximum and average flow rates, to see the influence of age, gender, and voided volume on flow rates, and to chart these values in the form of a nomogram. Methods: We evaluated 1,011 uroflowmetry tests in different age groups in a healthy population (healthy relatives of our patients) 16-50 year old males, >50 year old males, 5-15 year old children, and >15 year pre-menopausal and post-menopausal females. The uroflowmetry was done using the gravitimetric method. Flow chart parameters were analyzed and statistical calculations were used for drawing uroflow nomograms. Results: Qmax values in adult males were significantly higher than in the elderly and Qmax values in young females were significantly higher than in young males. Qmax values in males increased with age until 15 years old; followed by a slow decline until reaching 50 years old followed by a rapid decline after 50 years old even after correcting voided volume. Qmax values in females increased with age until they reached age 15 followed by decline in flow rate until a pre-menopausal age followed by no significant decline in post-menopausal females. Qmax values increased with voided volume until 700 cc followed by a plateau and decline. Conclusions: Qmax values more significantly correlated with age and voided volume than Qavg. Nomograms were drawn in centile form to provide normal reference ranges. Qmax values in our population were lower than described in literature. Patients with voided volume up to 50 ml could be evaluated with a nomogram. PMID:19955668

  15. Design and Uncertainty Analysis for a PVTt Gas Flow Standard

    PubMed Central

    Wright, John D.; Johnson, Aaron N.; Moldover, Michael R.

    2003-01-01

    A new pressure, volume, temperature, and, time (PVTt) primary gas flow standard at the National Institute of Standards and Technology has an expanded uncertainty (k = 2) of between 0.02 % and 0.05 %. The standard spans the flow range of 1 L/min to 2000 L/min using two collection tanks and two diverter valve systems. The standard measures flow by collecting gas in a tank of known volume during a measured time interval. We describe the significant and novel features of the standard and analyze its uncertainty. The gas collection tanks have a small diameter and are immersed in a uniform, stable, thermostatted water bath. The collected gas achieves thermal equilibrium rapidly and the uncertainty of the average gas temperature is only 7 mK (22 × 10−6 T). A novel operating method leads to essentially zero mass change in and very low uncertainty contributions from the inventory volume. Gravimetric and volume expansion techniques were used to determine the tank and the inventory volumes. Gravimetric determinations of collection tank volume made with nitrogen and argon agree with a standard deviation of 16 × 10−6 VT. The largest source of uncertainty in the flow measurement is drift of the pressure sensor over time, which contributes relative standard uncertainty of 60 × 10−6 to the determinations of the volumes of the collection tanks and to the flow measurements. Throughout the range 3 L/min to 110 L/min, flows were measured independently using the 34 L and the 677 L collection systems, and the two systems agreed within a relative difference of 150 × 10−6. Double diversions were used to evaluate the 677 L system over a range of 300 L/min to 1600 L/min, and the relative differences between single and double diversions were less than 75 × 10−6. PMID:27413592

  16. Relativistic top: An application of the BFV quantization procedure for systems with degenerate constraints

    NASA Astrophysics Data System (ADS)

    Nielsen, N. K.; Quaade, U. J.

    1995-07-01

    The physical phase space of the relativistic top, as defined by Hansson and Regge, is expressed in terms of canonical coordinates of the Poincaré group manifold. The system is described in the Hamiltonian formalism by the mass-shell condition and constraints that reduce the number of spin degrees of freedom. The constraints are second class and are modified into a set of first class constraints by adding combinations of gauge-fixing functions. The Batalin-Fradkin-Vilkovisky method is then applied to quantize the system in the path integral formalism in Hamiltonian form. It is finally shown that different gauge choices produce different equivalent forms of the constraints.

  17. The quantization of the chiral Schwinger model based on the BFT - BFV formalism

    NASA Astrophysics Data System (ADS)

    Kim, Won T.; Kim, Yong-Wan; Park, Mu-In; Park, Young-Jai; Yoon, Sean J.

    1997-03-01

    We apply the newly improved Batalin - Fradkin - Tyutin (BFT) Hamiltonian method to the chiral Schwinger model in the case of the regularization ambiguity a>1. We show that one can systematically construct the first class constraints by the BFT Hamiltonian method, and also show that the well-known Dirac brackets of the original phase space variables are exactly the Poisson brackets of the corresponding modified fields in the extended phase space. Furthermore, we show that the first class Hamiltonian is simply obtained by replacing the original fields in the canonical Hamiltonian by these modified fields. Performing the momentum integrations, we obtain the corresponding first class Lagrangian in the configuration space.

  18. BRST theory without Hamiltonian and Lagrangian

    NASA Astrophysics Data System (ADS)

    Lyakhovich, S. L.; Sharapov, A. A.

    2005-03-01

    We consider a generic gauge system, whose physical degrees of freedom are obtained by restriction on a constraint surface followed by factorization with respect to the action of gauge transformations; in so doing, no Hamiltonian structure or action principle is supposed to exist. For such a generic gauge system we construct a consistent BRST formulation, which includes the conventional BV Lagrangian and BFV Hamiltonian schemes as particular cases. If the original manifold carries a weak Poisson structure (a bivector field giving rise to a Poisson bracket on the space of physical observables) the generic gauge system is shown to admit deformation quantization by means of the Kontsevich formality theorem. A sigma-model interpretation of this quantization algorithm is briefly discussed.

  19. General covariance, topological quantum field theories and fractional statistics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gamboa, J.

    1992-01-20

    Topological quantum field theories and fractional statistics are both defined in multiply connected manifolds. The authors study the relationship between both theories in 2 + 1 dimensions and the authors show that, due to the multiply-connected character of the manifold, the propagator for any quantum (field) theory always contains a first order pole that can be identified with a physical excitation with fractional spin. The article starts by reviewing the definition of general covariance in the Hamiltonian formalism, the gauge-fixing problem and the quantization following the lines of Batalin, Fradkin and Vilkovisky. The BRST-BFV quantization is reviewed in order tomore » understand the topological approach proposed here.« less

  20. Experimental study of subaqueous, clay-rich, gravity flows

    NASA Astrophysics Data System (ADS)

    Marr, J.; Pratson, L.

    2003-04-01

    Recent laboratory experiments suggest a broad spectrum of flow and depositional behavior for compositionally varied subaqueous gravity flows. Dilute turbidity currents and cohesive debris flows are the end members of the spectrum. In this study we used geometrically scaled laboratory experiments to examine the flow dynamics and deposits associated with slurries of varying sediment composition. Slurries were composed of a mixture of tap water, kaolinite clay, 45 micron silt and 120 micron sand and were introduced into a 0.2m wide submerged channel. Slurry sediment concentrations ranged from 1-30% by volume. In all slurries, sediment was added in a ratio of 8:1:1 by volume of clay, silt, sand. A total volume of one cubic meter of slurry was used for each experiment and was introduced through a constant head tank allowing examination of sustained and steady gravity flow events lasting up to 5 minutes in duration. The dynamics of the flows (turbulence, hydroplaning, laminar shearing, etc.) were examined through the use of digital video cameras, dye injection tracking, high frequency sonar and visual observation. Vertical suspended sediment concentration and vertical grain size distributions were measured for each run from samples collected from siphon rakes. Deposit thicknesses and grain size distributions were measured from sediment samples taken from flow deposits. Rheological measurements and Atterberg limits of the slurries were made in an effort to link flow and depositional characteristics to bulk properties of the slurry mixture. The experiments show a clear linkage between the initial compositions of the slurries, their rheological properties, flow dynamics and deposits. Slurries with clay concentrations below 10% by volume appeared to be very turbulent. The silt and sand deposited during these events were transported along the bed as ripples. Flows between 10-20% sediment by volume appeared to be hybrid flows having both turbulent and non-turbulent elements. The surfaces of these deposits were flat and featureless. Slurries with sediment concentrations between 25-30% were clearly debris flows. They had distinguishable laminar flow and the deposit surfaces had both compression features and tension cracks.

  1. 40 CFR 60.73a - Emissions testing and monitoring.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... system (e.g., weigh scale, volume flow meter, mass flow meter, tank volume) to measure and record the... via titration or by determining the temperature and specific gravity of the nitric acid. You may also...

  2. 40 CFR 60.73a - Emissions testing and monitoring.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... system (e.g., weigh scale, volume flow meter, mass flow meter, tank volume) to measure and record the... via titration or by determining the temperature and specific gravity of the nitric acid. You may also...

  3. Methodology update for estimating volume to service flow ratio.

    DOT National Transportation Integrated Search

    2015-12-01

    Volume/service flow ratio (VSF) is calculated by the Highway Performance Monitoring System (HPMS) software as an indicator of peak hour congestion. It is an essential input to the Kentucky Transportation Cabinets (KYTC) key planning applications, ...

  4. Effects of coil closure of patent ductus arteriosus on left anterior descending coronary artery blood flow using transthoracic Doppler echocardiography.

    PubMed

    Harada, Kenji; Toyono, Manotomo; Tamura, Masamichi

    2004-06-01

    Transthoracic Doppler echocardiography provides noninvasive measurements of coronary blood flow in the left anterior descending coronary artery (LAD). This method has the potential to show the effects of acute changes in loading conditions on blood flow. Coil closure of patent ductus arteriosus (PDA) is a model of acute changes in blood pressure and left ventricular (LV) preload that influences coronary blood flow. We applied this technique to assess the coronary blood flow changes for patients with PDA before and immediately after PDA coil closure. We examined 9 patients (1.8 +/- 1.1 years) with simple PDA and 8 age-matched healthy children. LV dimensions and LV mass were measured. Maximum peak flow velocity and flow volume in the LAD were measured. Pulmonary to systemic flow ratios (Qp/Qs) were obtained by cardiac catheterization. After PDA coil closure, LV end-diastolic dimension decreased, and systolic and diastolic blood pressures increased significantly. The maximum peak flow velocity, LAD flow volume, and the ratio of LAD flow volume to LV mass increased significantly. The changes in maximum peak flow velocity and the ratio of LAD flow volume to LV mass (F/M) correlated positively with the changes in diastolic pressure and Qp/Qs. In 5 patients who had Qp/Qs > 1.5, the mean F/M was significantly lower compared with control subjects, but they increased to normal values after coil closure of PDA. PDA coil closure increases diastolic pressure and decreases Qp/Qs, resulting in improvement of myocardial perfusion. These findings provide new insights into the relationship between cardiac function and coronary circulation in pediatric patients with heart diseases associated with PDA.

  5. Strategies for Effectively Visualizing a 3D Flow Using Volume Line Integral Convolution

    NASA Technical Reports Server (NTRS)

    Interrante, Victoria; Grosch, Chester

    1997-01-01

    This paper discusses strategies for effectively portraying 3D flow using volume line integral convolution. Issues include defining an appropriate input texture, clarifying the distinct identities and relative depths of the advected texture elements, and selectively highlighting regions of interest in both the input and output volumes. Apart from offering insights into the greater potential of 3D LIC as a method for effectively representing flow in a volume, a principal contribution of this work is the suggestion of a technique for generating and rendering 3D visibility-impeding 'halos' that can help to intuitively indicate the presence of depth discontinuities between contiguous elements in a projection and thereby clarify the 3D spatial organization of elements in the flow. The proposed techniques are applied to the visualization of a hot, supersonic, laminar jet exiting into a colder, subsonic coflow.

  6. Are there benefits or harm from pressure targeting during lung-protective ventilation?

    PubMed

    MacIntyre, Neil R; Sessler, Curtis N

    2010-02-01

    Mechanically, breath design is usually either flow/volume-targeted or pressure-targeted. Both approaches can effectively provide lung-protective ventilation, but they prioritize different ventilation parameters, so their responses to changing respiratory-system mechanics and patient effort are different. These different response behaviors have advantages and disadvantages that can be important in specific circumstances. Flow/volume targeting guarantees a set minute ventilation but sometimes may be difficult to synchronize with patient effort, and it will not limit inspiratory pressure. In contrast, pressure targeting, with its variable flow, may be easier to synchronize and will limit inspiratory pressure, but it provides no control over delivered volume. Skilled clinicians can maximize benefits and minimize problems with either flow/volume targeting or pressure targeting. Indeed, as is often the case in managing complex life-support devices, it is operator expertise rather than the device design features that most impacts patient outcomes.

  7. The effect of balance holes to centrifugal pump performance

    NASA Astrophysics Data System (ADS)

    Babayigit, O.; Ozgoren, M.; Aksoy, M. H.; Kocaaslan, O.

    2017-07-01

    The aim of this study is to analyze of a centrifugal pump with and without balance holes by using ANSYS-Fluent software. The pump used in the study is a commercial centrifugal pump consisting of two stages that is a model of Sempa Pump Company. Firstly, models of impeller, diffuser, suction and discharge sections of the centrifugal pump were separately drawn using Ansys and Solidworks software. Later, grid structures were generated on the flow volume of the pump. Turbulent flow volume was numerically solved by realizable k-є turbulence model. The flow analyses were focused on the centrifugal pump performance and the flow characteristics under different operational conditions with/without balance holes. Distributions of flow characteristics such as velocity and pressure distributions in the flow volume were also determined, numerically. The results of Computational Fluid Dynamics (CFD) with/without balance holes for the pump head and hydraulic efficiency on the design flow rate of 80 m3/h were found to be 81.5/91.3 m and 51.9/65.3%, respectively.

  8. In Vitro Validation of Real-Time Three-Dimensional Color Doppler Echocardiography for Direct Measurement of Proximal Isovelocity Surface Area in Mitral Regurgitation

    PubMed Central

    Little, Stephen H.; Igo, Stephen R.; Pirat, Bahar; McCulloch, Marti; Hartley, Craig J.; Nosé, Yukihiko; Zoghbi, William A.

    2012-01-01

    The 2-dimensional (2D) color Doppler (2D-CD) proximal isovelocity surface area (PISA) method assumes a hemispheric flow convergence zone to estimate transvalvular flow. Recently developed 3-dimensional (3D)-CD can directly visualize PISA shape and surface area without geometric assumptions. To validate a novel method to directly measure PISA using real-time 3D-CD echocardiography, a circulatory loop with an ultrasound imaging chamber was created to model mitral regurgitation (MR). Thirty-two different regurgitant flow conditions were tested using symmetric and asymmetric flow orifices. Three-dimensional–PISA was reconstructed from a hand-held real-time 3D-CD data set. Regurgitant volume was derived using both 2D-CD and 3D-CD PISA methods, and each was compared against a flowmeter standard. The circulatory loop achieved regurgitant volume within the clinical range of MR (11 to 84 ml). Three-dimensional–PISA geometry reflected the 2D geometry of the regurgitant orifice. Correlation between the 2D-PISA method regurgitant volume and actual regurgitant volume was significant (r2 = 0.47, p <0.001). Mean 2D-PISA regurgitant volume underestimate was 19.1 ± 25 ml (2 SDs). For the 3D-PISA method, correlation with actual regurgitant volume was significant (r2 = 0.92, p <0.001), with a mean regurgitant volume underestimate of 2.7 ± 10 ml (2 SDs). The 3D-PISA method showed less regurgitant volume underestimation for all orifice shapes and regurgitant volumes tested. In conclusion, in an in vitro model of MR, 3D-CD was used to directly measure PISA without geometric assumption. Compared with conventional 2D-PISA, regurgitant volume was more accurate when derived from 3D-PISA across symmetric and asymmetric orifices within a broad range of hemodynamic flow conditions. PMID:17493476

  9. Forced expirations and maximum expiratory flow-volume curves during sustained microgravity on SLS-1.

    PubMed

    Elliott, A R; Prisk, G K; Guy, H J; Kosonen, J M; West, J B

    1996-07-01

    Gravity is known to influence the mechanical behavior of the lung and chest wall. However, the effect of sustained microgravity (microG) on forced expirations has not previously been reported. Tests were carried out by four subjects in both the standing and supine postures during each of seven preflight and four postflight data-collection sessions and four times during the 9 days of microG exposure on Spacelab Life Sciences-1. Compared with preflight standing values, peak expiratory flow rate (PEFR) was significantly reduced by 12.5% on flight day 2 (FD2), 11.6% on FD4, and 5.0% on FD5 but returned to standing values by FD9. The supine posture caused a 9% reduction in PEFR. Forced vital capacity and forced expired volume in 1 s were slightly reduced (approximately 3-4%) on FD2 but returned to preflight standing values on FD4 and FD5, and by FD9 both values were slightly but significantly greater than standing values. Forced vital capacity and forced expiratory volume in 1 s were both reduced in the supine posture (approximately 8-10%). Forced expiratory flows at 50% and between 25 and 75% of vital capacity did not change during microG but were reduced in the supine posture. Analysis of the maximum expiratory flow-volume curve showed that microG caused no consistent change in the curve configuration when individual in-flight days were compared with preflight standing curves, although two subjects did show a slight reduction in flows at low lung volumes from FD2 to FD9. The interpretation of the lack of change in curve configuration must be made cautiously because the lung volumes varied from day to day in flight. Therefore, the flows at absolute lung volumes in microG and preflight standing are not being compared. The supine curves showed a subtle but consistent reduction in flows at low lung volumes. The mechanism responsible for the reduction in PEFR is not clear. It could be due to a lack of physical stabilization when performing the maneuver in the absence of gravity or a transient reduction in respiratory muscle strength.

  10. Differential effects of lower body negative pressure and upright tilt on splanchnic blood volume

    PubMed Central

    Taneja, Indu; Moran, Christopher; Medow, Marvin S.; Glover, June L.; Montgomery, Leslie D.; Stewart, Julian M.

    2015-01-01

    Upright posture and lower body negative pressure (LBNP) both induce reductions in central blood volume. However, regional circulatory responses to postural changes and LBNP may differ. Therefore, we studied regional blood flow and blood volume changes in 10 healthy subjects undergoing graded lower-body negative pressure (−10 to −50 mmHg) and 8 subjects undergoing incremental head-up tilt (HUT; 20°, 40°, and 70°) on separate days. We continuously measured blood pressure (BP), heart rate, and regional blood volumes and blood flows in the thoracic, splanchnic, pelvic, and leg segments by impedance plethysmography and calculated regional arterial resistances. Neither LBNP nor HUT altered systolic BP, whereas pulse pressure decreased significantly. Blood flow decreased in all segments, whereas peripheral resistances uniformly and significantly increased with both HUT and LBNP. Thoracic volume decreased while pelvic and leg volumes increased with HUT and LBNP. However, splanchnic volume changes were directionally opposite with stepwise decreases in splanchnic volume with LBNP and stepwise increases in splanchnic volume during HUT. Splanchnic emptying in LBNP models regional vascular changes during hemorrhage. Splanchnic filling may limit the ability of the splanchnic bed to respond to thoracic hypovolemia during upright posture. PMID:17085534

  11. Ventricular distension and diastolic coronary blood flow in the anaesthetized dog.

    PubMed

    Gattullo, D; Linden, R J; Losano, G; Pagliaro, P; Westerhof, N

    1993-01-01

    There appears to be no agreement as to whether or not an increase in diastolic left ventricular pressure and/or volume can cause a decrease in diastolic coronary blood flow. We investigated the problem in the anaesthetized dog using a flaccid freely distensible latex balloon inserted into the left ventricle with the animal on extracorporeal circulation and the coronary perfusion pressure constant at about 45 mm Hg. Maximal vasodilatation and suppression of autoregulation in coronary vasculature was obtained by the intracoronary infusion of dipyridamole (10-40 mg/h). Ventricular volume was changed in steps of 10 ml from 10 to 70 ml and back to 10 ml, whilst recording coronary blood flow and left ventricular pressure in the left circumflex coronary artery. Over a range of ventricular volumes from 20 to 50 ml and a concomitant rise in diastolic ventricular pressure to about 20 mm Hg there was no change in the diastolic coronary flow. Only when the ventricular volume was more than two times the control value (i.e. exceeded 50 ml) and left ventricular pressure was more than 20 mm Hg, was there a decrease in coronary flow. During the return of the volume to the control level there was a fall in diastolic flow and ventricular contractility with respect to the values obtained when the volume was increased; these two effects were transient lasting less than 10 min. It was not considered that any of the three models of the coronary circulation, waterfall, intramyocardial pump or varying elastance model could explain our results.(ABSTRACT TRUNCATED AT 250 WORDS)

  12. ρ-VOF: An interface sharpening method for gas-liquid flow simulation

    NASA Astrophysics Data System (ADS)

    Wang, Jiantao; Liu, Gang; Jiang, Xiong; Mou, Bin

    2018-05-01

    The study on simulation of compressible gas-liquid flow remains open. Popular methods are either confined to incompressible flow regime, or inevitably induce smear of the free interface. A new finite volume method for compressible two-phase flow simulation is contributed for this subject. First, the “heterogeneous equilibrium” assumption is introduced to the control volume, by hiring free interface reconstruction technology, the distribution of each component in the control volume is achieved. Next, AUSM+-up (advection upstream splitting method) scheme is employed to calculate the convective fluxes and pressure fluxes, with the contact discontinuity characteristic considered, followed by the update of the whole flow field. The new method features on density-based pattern and interface reconstruction technology from VOF (volume of fluid), thus we name it “ρ-VOF method”. Inherited from AUSM families and VOF, ρ-VOF behaves as an all-speed method, capable of simulating shock in gas-liquid flow, and preserving the sharpness of the free interface. Gas-liquid shock tube is simulated to evaluate the method, from which good agreement is obtained between the predicted results and those of the cited literature, meanwhile, sharper free interface is identified. Finally, the capability and validity of ρ-VOF method can be concluded in compressible gas-liquid flow simulation.

  13. Power Flow in Phonation

    NASA Astrophysics Data System (ADS)

    Zhang, Lucy; Yu, Feimi; Krane, Michael

    2017-11-01

    The control volume analysis of power flow during sustained phonation is performed using results of a fully-coupled aeroelastic-aeroacoustic simulation. The control volumes consist of the laryngeal region, and the larynx and the vocal tract. Two cases are considered: an effectively infinite length vocal tract, where sound produced in the larynx radiates away and is not reflected back, and a constant-area vocal tract of normal adult human dimensions, in which phonatory sound resonates before radiating from the mouth opening. In both cases the lungs are modeled to absorb all incident sound, while providing a constant volume flow toward the larynx. Control of the acoustic boundary conditions is accomplished using perfectly matched- layers, and flow from the lungs is provided by a source distribution near the entrance to the trachea region. For both cases the power flow for the larynx and larynx plus vocal tract control volumes are computed using the integral form of the mechanical energy equation, expanded to consider power exchanges between slightly compressible flow in the larynx and the acoustic fields in the vocal tract and trachea. The funding from NIH 2R01DC005642-10A1 is greatly acknowledged.

  14. The relationship between sap-flow rate and sap volume in dormant sugar maples

    Treesearch

    William J. Gabriel; Russell S. Walters; Donald W. Seegrist

    1972-01-01

    Sap-flow rate is closely correlated with the sap volume produced by dormant sugar maple trees (Acer saccharum Marsh.) and could be used in making phenotypic selections of trees for superior sap production.

  15. Logging effects on streamflow: storm runoff at Caspar Creek in northwestern California

    Treesearch

    Kenneth A. Wright; Sendek Karen H.; Raymond M. Rice; Robert B. Thomas

    1990-01-01

    This paper reports a study to determine whether road building and selective harvesting at Caspar Creek in northwestern California increased total storm volumes, quick flow volumes, or peak flows or altered the lag times

  16. Systems and methods for separating a multiphase fluid

    NASA Technical Reports Server (NTRS)

    Weislogel, Mark M. (Inventor); Thomas, Evan A. (Inventor); Graf, John C. (Inventor)

    2011-01-01

    Apparatus and methods for separating a fluid are provided. The apparatus can include a separator and a collector having an internal volume defined at least in part by one or more surfaces narrowing toward a bottom portion of the volume. The separator can include an exit port oriented toward the bottom portion of the volume. The internal volume can receive a fluid expelled from the separator into a flow path in the collector and the flow path can include at least two directional transitions within the collector.

  17. A solution algorithm for fluid–particle flows across all flow regimes

    DOE PAGES

    Kong, Bo; Fox, Rodney O.

    2017-05-12

    Many fluid–particle flows occurring in nature and in technological applications exhibit large variations in the local particle volume fraction. For example, in circulating fluidized beds there are regions where the particles are closepacked as well as very dilute regions where particle–particle collisions are rare. Thus, in order to simulate such fluid–particle systems, it is necessary to design a flow solver that can accurately treat all flow regimes occurring simultaneously in the same flow domain. In this work, a solution algorithm is proposed for this purpose. The algorithm is based on splitting the free-transport flux solver dynamically and locally in themore » flow. In close-packed to moderately dense regions, a hydrodynamic solver is employed, while in dilute to very dilute regions a kinetic-based finite-volume solver is used in conjunction with quadrature-based moment methods. To illustrate the accuracy and robustness of the proposed solution algorithm, it is implemented in OpenFOAM for particle velocity moments up to second order, and applied to simulate gravity-driven, gas–particle flows exhibiting cluster-induced turbulence. By varying the average particle volume fraction in the flow domain, it is demonstrated that the flow solver can handle seamlessly all flow regimes present in fluid–particle flows.« less

  18. A solution algorithm for fluid-particle flows across all flow regimes

    NASA Astrophysics Data System (ADS)

    Kong, Bo; Fox, Rodney O.

    2017-09-01

    Many fluid-particle flows occurring in nature and in technological applications exhibit large variations in the local particle volume fraction. For example, in circulating fluidized beds there are regions where the particles are close-packed as well as very dilute regions where particle-particle collisions are rare. Thus, in order to simulate such fluid-particle systems, it is necessary to design a flow solver that can accurately treat all flow regimes occurring simultaneously in the same flow domain. In this work, a solution algorithm is proposed for this purpose. The algorithm is based on splitting the free-transport flux solver dynamically and locally in the flow. In close-packed to moderately dense regions, a hydrodynamic solver is employed, while in dilute to very dilute regions a kinetic-based finite-volume solver is used in conjunction with quadrature-based moment methods. To illustrate the accuracy and robustness of the proposed solution algorithm, it is implemented in OpenFOAM for particle velocity moments up to second order, and applied to simulate gravity-driven, gas-particle flows exhibiting cluster-induced turbulence. By varying the average particle volume fraction in the flow domain, it is demonstrated that the flow solver can handle seamlessly all flow regimes present in fluid-particle flows.

  19. A solution algorithm for fluid–particle flows across all flow regimes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kong, Bo; Fox, Rodney O.

    Many fluid–particle flows occurring in nature and in technological applications exhibit large variations in the local particle volume fraction. For example, in circulating fluidized beds there are regions where the particles are closepacked as well as very dilute regions where particle–particle collisions are rare. Thus, in order to simulate such fluid–particle systems, it is necessary to design a flow solver that can accurately treat all flow regimes occurring simultaneously in the same flow domain. In this work, a solution algorithm is proposed for this purpose. The algorithm is based on splitting the free-transport flux solver dynamically and locally in themore » flow. In close-packed to moderately dense regions, a hydrodynamic solver is employed, while in dilute to very dilute regions a kinetic-based finite-volume solver is used in conjunction with quadrature-based moment methods. To illustrate the accuracy and robustness of the proposed solution algorithm, it is implemented in OpenFOAM for particle velocity moments up to second order, and applied to simulate gravity-driven, gas–particle flows exhibiting cluster-induced turbulence. By varying the average particle volume fraction in the flow domain, it is demonstrated that the flow solver can handle seamlessly all flow regimes present in fluid–particle flows.« less

  20. The unique contribution of manual chest compression-vibrations to airflow during physiotherapy in sedated, fully ventilated children.

    PubMed

    Gregson, Rachael K; Shannon, Harriet; Stocks, Janet; Cole, Tim J; Peters, Mark J; Main, Eleanor

    2012-03-01

    This study aimed to quantify the specific effects of manual lung inflations with chest compression-vibrations, commonly used to assist airway clearance in ventilated patients. The hypothesis was that force applied during the compressions made a significant additional contribution to increases in peak expiratory flow and expiratory to inspiratory flow ratio over and above that resulting from accompanying increases in inflation volume. Prospective observational study. Cardiac and general pediatric intensive care. Sedated, fully ventilated children. Customized force-sensing mats and a commercial respiratory monitor recorded force and respiration during physiotherapy. Percentage changes in peak expiratory flow, peak expiratory to inspiratory flow ratios, inflation volume, and peak inflation pressure between baseline and manual inflations with and without compression-vibrations were calculated. Analysis of covariance determined the relative contribution of changes in pressure, volume, and force to influence changes in peak expiratory flow and peak expiratory to inspiratory flow ratio. Data from 105 children were analyzed (median age, 1.3 yrs; range, 1 wk to 15.9 yrs). Force during compressions ranged from 15 to 179 N (median, 46 N). Peak expiratory flow increased on average by 76% during compressions compared with baseline ventilation. Increases in peak expiratory flow were significantly related to increases in inflation volume, peak inflation pressure, and force with peak expiratory flow increasing by, on average, 4% for every 10% increase in inflation volume (p < .001), 5% for every 10% increase in peak inflation pressure (p = .005), and 3% for each 10 N of applied force (p < .001). By contrast, increase in peak expiratory to inspiratory flow ratio was only related to applied force with a 4% increase for each 10 N of force (p < .001). These results provide evidence of the unique contribution of compression forces in increasing peak expiratory flow and peak expiratory to inspiratory flow ratio bias over and above that related to accompanying changes from manual hyperinflations. Force generated during compression-vibrations was the single significant factor in multivariable analysis to explain the increases in expiratory flow bias. Such increases in the expiratory bias provide theoretically optimal physiological conditions for cephalad mucus movement in fully ventilated children.

  1. Nanoindentation study on the characteristic of shear transformation zone in a Pd-based bulk metallic glass during serrated flow

    NASA Astrophysics Data System (ADS)

    Liao, G. K.; Long, Z. L.; Zhao, M. S. Z.; Peng, L.; Chai, W.; Ping, Z. H.

    2018-04-01

    This paper presents the research on the evolution of shear transformation zone (STZ) in a Pd-based bulk metallic glass (BMG) during serrated flow under nanoindentation. A novel method of estimating the STZ volume through statistical analysis of the serrated flow behavior was proposed for the first time. Based on the proposed method, the STZ volume of the studied BMG at various peak loads have been systematically investigated. The results indicate that the measured STZ volumes are in good agreement with that documented in literature, and the STZ size exhibits an increasing trend during indentation. Moreover, the correlation between the serrated flow dynamics and the STZ activation has also been evaluated. It is found that the STZ activation can promote the formation of self-organized critical (SOC) state during serrated flow.

  2. Enhanced ventricular pump function and decreased reservoir backflow sustain rise in pulmonary blood flow after reduction of lung liquid volume in fetal lambs.

    PubMed

    Smolich, Joseph J

    2014-02-15

    Although a reduction in lung liquid volume increases fetal pulmonary blood flow, the changes in central flow patterns that sustain this increased pulmonary perfusion are unknown. To address this issue, eight anesthetized late-gestation fetal sheep were instrumented with pulmonary trunk (PT), ductus arteriosus (DA), and left pulmonary artery (PA) micromanometer catheters and transit-time flow probes, with blood flow profile and wave intensity analyses performed at baseline and after withdrawal of lung liquid via an endotracheal tube. Reducing lung liquid volume by 19 ± 6 ml/kg (mean ± SD) augmented right ventricular power by 34% (P < 0.001), with distribution of an accompanying increase in mean PT blood flow (245 ± 63 ml/min, P < 0.001) to the lungs (169 ± 91 ml/min, P = 0.001) and across the DA (77 ± 92 ml/min, P = 0.04). However, although PT and DA flow increments were confined to systole and were related to an increased magnitude of flow-increasing, forward-running compression waves, the rise in PA flow spanned both systole (108 ± 66 ml/min) and diastole (61 ± 32 ml/min). Flow profile analysis showed that the step-up in PA diastolic flow was associated with diminished PA diastolic backflow and accompanied by a lesser degree of diastolic right-to-left DA shunting. These data suggest that an increased pulmonary blood flow after reduction of lung liquid volume is associated with substantial changes in PT-DA-PA interactions and underpinned by two main factors: 1) enhanced right ventricular pump function that increases PA systolic inflow and 2) decreased PA diastolic backflow that arises from a fundamental change in PA reservoir function, thereby resulting in greater passage of systolic inflow through the lungs.

  3. Numerical and experimental investigation of the 3D free surface flow in a model Pelton turbine

    NASA Astrophysics Data System (ADS)

    Fiereder, R.; Riemann, S.; Schilling, R.

    2010-08-01

    This investigation focuses on the numerical and experimental analysis of the 3D free surface flow in a Pelton turbine. In particular, two typical flow conditions occurring in a full scale Pelton turbine - a configuration with a straight inlet as well as a configuration with a 90 degree elbow upstream of the nozzle - are considered. Thereby, the effect of secondary flow due to the 90 degree bending of the upstream pipe on the characteristics of the jet is explored. The hybrid flow field consists of pure liquid flow within the conduit and free surface two component flow of the liquid jet emerging out of the nozzle into air. The numerical results are validated against experimental investigations performed in the laboratory of the Institute of Fluid Mechanics (FLM). For the numerical simulation of the flow the in-house unstructured fully parallelized finite volume solver solver3D is utilized. An advanced interface capturing model based on the classic Volume of Fluid method is applied. In order to ensure sharp interface resolution an additional convection term is added to the transport equation of the volume fraction. A collocated variable arrangement is used and the set of non-linear equations, containing fluid conservation equations and model equations for turbulence and volume fraction, are solved in a segregated manner. For pressure-velocity coupling the SIMPLE and PISO algorithms are implemented. Detailed analysis of the observed flow patterns in the jet and of the jet geometry are presented.

  4. Multiphase flowmeter successfully measures three-phase flow at extremely high gas-volume fractions -- Gulf of Suez, Egypt

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leggett, R.B.; Borling, D.C.; Powers, B.S.

    1998-02-01

    A multiphase flowmeter (MPFM) installed in offshore Egypt has accurately measured three-phase flow in extremely gassy flow conditions. The meter is completely nonintrusive, with no moving parts, requires no flow mixing before measurement, and has no bypass loop to remove gas before multiphase measurement. Flow regimes observed during the field test of this meter ranged from severe slugging to annular flow caused by the dynamics of gas-lift gas in the production stream. Average gas-volume fraction ranged from 93 to 98% during tests conducted on seven wells. The meter was installed in the Gulf of Suez on a well protector platformmore » in the Gulf of Suez Petroleum Co. (Gupco) October field, and was placed in series with a test separator located on a nearby production platform. Wells were individually tested with flow conditions ranging from 1,300 to 4,700 B/D fluid, 2.4 to 3.9 MMscf/D of gas, and water cuts from 1 to 52%. The meter is capable of measuring water cuts up to 100%. Production was routed through both the MPFM and the test separator simultaneously as wells flowed with the assistance of gas-lift gas. The MPFM measured gas and liquid rates to within {+-} 10% of test-separator reference measurement flow rates, and accomplished this at gas-volume fractions from 93 to 96%. At higher gas-volume fractions up to 98%, accuracy deteriorated but the meter continued to provide repeatable results.« less

  5. Can MR Measurement of Renal Artery Flow and Renal Volume Predict the Outcome of Percutaneous Transluminal Renal Angioplasty?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Binkert, Christoph A.; Debatin, Jorg F.; Schneider, Ernst

    2001-07-15

    Purpose: Predicting therapeutic benefit from percutaneous transluminal renal angioplasty (PTRA) in patients with renal artery stenosis (RAS) remains difficult. This study investigates whether magnetic resonance (MR)-based renal artery flow measurements relative to renal parenchymal volume can predict clinical outcome following PTRA.Methods: The data on 23 patients (13 men, 10 women; age range 47-82 years, mean age 64 years) were analyzed. The indication for treatment was hypertension (n = 18) or renal insufficiency (n = 5). Thirty-four cases of RAS were identified: bilateral disease was manifest in 11 and unilateral disease in 12 patients. The MR imaging protocol included a breath-hold,more » cardiac-gated cine phase-contrast sequence for renal flow measurement and a fast multiplanar spoiled gradient-echo sequence for renal volume measurement. MR measurements were performed on the day prior to and the day following PTRA. Clinical success was defined as (a) a reduction in diastolic blood pressure > 15% or (b) a reduction in serum creatinine > 20%. Kidneys were categorized as normal volume or low volume. A renal flow index (RFI) was calculated by dividing the renal flow (ml/min) by the renal volume (cm{sup 3}).Results: Clinical success was observed in 11 patients. Twelve patients did not benefit from angioplasty. Normal kidney volume was seen in 10 of 11 responders and in 8 of 12 nonresponders, resulting in a sensitivity of 91%, specificity of 33%, a positive predictive value (PPV) of 56% and a negative predictive value (NPV) of 80%. A RFI below a threshold of 1.5 ml/min/cm{sup 3} predicted successful outcome with 100% sensitivity, 33% specificity, 58% PPV, and 100% NPV. The combination of normal renal volume and a RFI below 1.5 ml/min/cm{sup 3} identified PTRA responders with a sensitivity of 91%, a specificity of 67%, a PPV of 71%, and a NPV of 89%. PTRA resulted in a greater increase in renal flow in responders compared with nonresponders (p < 0.001).Conclusion: A combination of cine phase-contrast MR renal flow and parenchymal volume measurements enables identification of patients benefiting from PTRA with a high sensitivity and NPV, but only moderate specificity and PPV.« less

  6. Long, paired A'A/Pahoehoe flows of Mauna Loa: Volcanological significance and insights they provide into volcano plumbing systems

    NASA Technical Reports Server (NTRS)

    Rowland, Scott K.; Walker, George P. L.

    1987-01-01

    The long lava flows of Mauna Loa, Hawaii have been cited as Earth's closed analogs to the large Martian flows. It is therefore important to understand the flow mechanics and characteristics of the Mauna Loa flows and to make use of these in an attempt to gain insights into Martian eruptive processes. Two fundamentally different kinds of long lava flows can be distinguished on Hawaiian volcanoes as in Martian flows. The two kinds may have identical initial viscosities, chemical compositions, flow lengths, and flow volumes, but their flow mechanisms and thermal energy budgets are radically different. One travels a distance set by the discharge rate as envisaged by Walker and Wadge, and the other travels a distance set mainly by the eruption duration and ground slope. In the Mauna Loa lavas, yield strength becomes an important flow morphology control only in the distal part of a'a lavas. The occurrence of paired flows on Mauna Loa yields insights into the internal plumbing systems of the volcano, and it is significant that all of the volume of the a'a flow must be stored in a magma chamber before eruption, while none of the volume of the pahoehoe needs to be so stored. Differentiation between the two kinds of flows on images of Martian volcanoes is possible and hence an improved understanding of these huge structures is acquired.

  7. Urban Stormwater Runoff: A New Class of Environmental Flow Problem

    PubMed Central

    Walsh, Christopher J.; Fletcher, Tim D.; Burns, Matthew J.

    2012-01-01

    Environmental flow assessment frameworks have begun to consider changes to flow regimes resulting from land-use change. Urban stormwater runoff, which degrades streams through altered volume, pattern and quality of flow, presents a problem that challenges dominant approaches to stormwater and water resource management, and to environmental flow assessment. We used evidence of ecological response to different stormwater drainage systems to develop methods for input to environmental flow assessment. We identified the nature of hydrologic change resulting from conventional urban stormwater runoff, and the mechanisms by which such hydrologic change is prevented in streams where ecological condition has been protected. We also quantified the increase in total volume resulting from urban stormwater runoff, by comparing annual streamflow volumes from undeveloped catchments with the volumes that would run off impervious surfaces under the same rainfall regimes. In catchments with as little as 5–10% total imperviousness, conventional stormwater drainage, associated with poor in-stream ecological condition, reduces contributions to baseflows and increases the frequency and magnitude of storm flows, but in similarly impervious catchments in which streams retain good ecological condition, informal drainage to forested hillslopes, without a direct piped discharge to the stream, results in little such hydrologic change. In urbanized catchments, dispersed urban stormwater retention measures can potentially protect urban stream ecosystems by mimicking the hydrologic effects of informal drainage, if sufficient water is harvested and kept out of the stream, and if discharged water is treated to a suitable quality. Urban stormwater is a new class of environmental flow problem: one that requires reduction of a large excess volume of water to maintain riverine ecological integrity. It is the best type of problem, because solving it provides an opportunity to solve other problems such as the provision of water for human use. PMID:23029257

  8. Emptying patterns of the lung studied by multiple-breath N2 washout

    NASA Technical Reports Server (NTRS)

    Lewis, S. M.

    1978-01-01

    Changes in the nitrogen concentration seen during the single-breath nitrogen washout reflect changes in relative flow (ventilation) from units with differing ventilation/volume ratios. The multiple-breath washout provides sufficient data on ventilation for units with varying ventilation/volume ratios to be plotted as a function of the volume expired. Flow from the dead space may also be determined. In young normals the emptying patterns are narrow and unimodal throughout the alveolar plateau with little or no flow from the dead space at the end of the breath. Older normals show more flow from the dead space, particularly toward the end of the breath, and some show a high ventilation/volume ratio mode early in the breath. Patients with obstructive lung disease have a high flow from the dead space which is present throughout the breath. A well ventilated mode at the end of the breath is seen in some obstructed subjects. Patients with cystic fibrosis showed a poorly ventilated mode appearing at the end of the breath as well as a very high dead space.

  9. Water-vapor pressure control in a volume

    NASA Technical Reports Server (NTRS)

    Scialdone, J. J.

    1978-01-01

    The variation with time of the partial pressure of water in a volume that has openings to the outside environment and includes vapor sources was evaluated as a function of the purging flow and its vapor content. Experimental tests to estimate the diffusion of ambient humidity through openings and to validate calculated results were included. The purging flows required to produce and maintain a certain humidity in shipping containers, storage rooms, and clean rooms can be estimated with the relationship developed here. These purging flows are necessary to prevent the contamination, degradation, and other effects of water vapor on the systems inside these volumes.

  10. Examining the effects of urban agglomeration polders on flood events in Qinhuai River basin, China with HEC-HMS model.

    PubMed

    Gao, Yuqin; Yuan, Yu; Wang, Huaizhi; Schmidt, Arthur R; Wang, Kexuan; Ye, Liu

    2017-05-01

    The urban agglomeration polders type of flood control pattern is a general flood control pattern in the eastern plain area and some of the secondary river basins in China. A HEC-HMS model of Qinhuai River basin based on the flood control pattern was established for simulating basin runoff, examining the impact of urban agglomeration polders on flood events, and estimating the effects of urbanization on hydrological processes of the urban agglomeration polders in Qinhuai River basin. The results indicate that the urban agglomeration polders could increase the peak flow and flood volume. The smaller the scale of the flood, the more significant the influence of the polder was to the flood volume. The distribution of the city circle polder has no obvious impact on the flood volume, but has effect on the peak flow. The closer the polder is to basin output, the smaller the influence it has on peak flows. As the level of urbanization gradually improving of city circle polder, flood volumes and peak flows gradually increase compared to those with the current level of urbanization (the impervious rate was 20%). The potential change in flood volume and peak flow with increasing impervious rate shows a linear relationship.

  11. Dissociation of local and global skeletal muscle oxygen transport metrics in type 2 diabetes.

    PubMed

    Mason McClatchey, P; Bauer, Timothy A; Regensteiner, Judith G; Schauer, Irene E; Huebschmann, Amy G; Reusch, Jane E B

    2017-08-01

    Exercise capacity is impaired in type 2 diabetes, and this impairment predicts excess morbidity and mortality. This defect appears to involve excess skeletal muscle deoxygenation, but the underlying mechanisms remain unclear. We hypothesized that reduced blood flow, reduced local recruitment of blood volume/hematocrit, or both contribute to excess skeletal muscle deoxygenation in type 2 diabetes. In patients with (n=23) and without (n=18) type 2 diabetes, we recorded maximal reactive hyperemic leg blood flow, peak oxygen utilization during cycling ergometer exercise (VO 2peak ), and near-infrared spectroscopy-derived measures of exercise-induced changes in skeletal muscle oxygenation and blood volume/hematocrit. We observed a significant increase (p<0.05) in skeletal muscle deoxygenation in type 2 diabetes despite similar blood flow and recruitment of local blood volume/hematocrit. Within the control group skeletal muscle deoxygenation, local recruitment of microvascular blood volume/hematocrit, blood flow, and VO 2peak are all mutually correlated. None of these correlations were preserved in type 2 diabetes. These results suggest that in type 2 diabetes 1) skeletal muscle oxygenation is impaired, 2) this impairment may occur independently of bulk blood flow or local recruitment of blood volume/hematocrit, and 3) local and global metrics of oxygen transport are dissociated. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Large volume flow-through scintillating detector

    DOEpatents

    Gritzo, Russ E.; Fowler, Malcolm M.

    1995-01-01

    A large volume flow through radiation detector for use in large air flow situations such as incinerator stacks or building air systems comprises a plurality of flat plates made of a scintillating material arranged parallel to the air flow. Each scintillating plate has a light guide attached which transfers light generated inside the scintillating plate to an associated photomultiplier tube. The output of the photomultiplier tubes are connected to electronics which can record any radiation and provide an alarm if appropriate for the application.

  13. Unconfined laminar nanofluid flow and heat transfer around a rotating circular cylinder in the steady regime

    NASA Astrophysics Data System (ADS)

    Bouakkaz, Rafik; Salhi, Fouzi; Khelili, Yacine; Quazzazi, Mohamed; Talbi, Kamel

    2017-06-01

    In this work, steady flow-field and heat transfer through a copper- water nanofluid around a rotating circular cylinder with a constant nondimensional rotation rate α varying from 0 to 5 was investigated for Reynolds numbers of 5-40. Furthermore, the range of nanoparticle volume fractions considered is 0-5%. The effect of volume fraction of nanoparticles on the fluid flow and heat transfer characteristics are carried out by using a finite-volume method based commercial computational fluid dynamics solver. The variation of the local and the average Nusselt numbers with Reynolds number, volume fractions, and rotation rate are presented for the range of conditions. The average Nusselt number is found to decrease with increasing value of the rotation rate for the fixed value of the Reynolds number and volume fraction of nanoparticles. In addition, rotation can be used as a drag reduction technique.

  14. Analysis and design of three dimensional supersonic nozzles. Volume 2: Numerical program for analysis of nozzle-exhaust flow fields

    NASA Technical Reports Server (NTRS)

    Kalben, P.

    1972-01-01

    The FORTRAN IV Program developed to analyze the flow field associated with scramjet exhaust systems is presented. The instructions for preparing input and interpreting output are described. The program analyzes steady three dimensional supersonic flow by the reference plane characteristic technique. The governing equations and numerical techniques employed are presented in Volume 1 of this report.

  15. Probability and volume of potential postwildfire debris flows in the 2012 High Park Burn Area near Fort Collins, Colorado

    USGS Publications Warehouse

    Verdin, Kristine L.; Dupree, Jean A.; Elliott, John G.

    2012-01-01

    This report presents a preliminary emergency assessment of the debris-flow hazards from drainage basins burned by the 2012 High Park fire near Fort Collins in Larimer County, Colorado. Empirical models derived from statistical evaluation of data collected from recently burned basins throughout the intermountain western United States were used to estimate the probability of debris-flow occurrence and volume of debris flows along the burned area drainage network and to estimate the same for 44 selected drainage basins along State Highway 14 and the perimeter of the burned area. Input data for the models included topographic parameters, soil characteristics, burn severity, and rainfall totals and intensities for a (1) 2-year-recurrence, 1-hour-duration rainfall (25 millimeters); (2) 10-year-recurrence, 1-hour-duration rainfall (43 millimeters); and (3) 25-year-recurrence, 1-hour-duration rainfall (51 millimeters). Estimated debris-flow probabilities along the drainage network and throughout the drainage basins of interest ranged from 1 to 84 percent in response to the 2-year-recurrence, 1-hour-duration rainfall; from 2 to 95 percent in response to the 10-year-recurrence, 1-hour-duration rainfall; and from 3 to 97 in response to the 25-year-recurrence, 1-hour-duration rainfall. Basins and drainage networks with the highest probabilities tended to be those on the eastern edge of the burn area where soils have relatively high clay contents and gradients are steep. Estimated debris-flow volumes range from a low of 1,600 cubic meters to a high of greater than 100,000 cubic meters. Estimated debris-flow volumes increase with basin size and distance along the drainage network, but some smaller drainages were also predicted to produce substantial volumes of material. The predicted probabilities and some of the volumes predicted for the modeled storms indicate a potential for substantial debris-flow impacts on structures, roads, bridges, and culverts located both within and immediately downstream from the burned area. Colorado State Highway 14 is also susceptible to impacts from debris flows.

  16. 2008 High-Flow Experiment at Glen Canyon Dam-Morphologic Response of Eddy-Deposited Sandbars and Associated Aquatic Backwater Habitats along the Colorado River in Grand Canyon National Park

    USGS Publications Warehouse

    Grams, Paul E.; Schmidt, John C.; Andersen, Matthew E.

    2010-01-01

    The March 2008 high-flow experiment (HFE) at Glen Canyon Dam resulted in sandbar deposition and sandbar reshaping such that the area and volume of associated backwater aquatic habitat in Grand Canyon National Park was greater following the HFE. Analysis of backwater habitat area and volume for 116 locations at 86 study sites, comparing one month before and one month after the HFE, shows that total habitat area increased by 30 percent to as much as a factor of 3 and that volume increased by 80 percent to as much as a factor of 15. These changes resulted from an increase in the area and elevation of sandbars, which isolate backwaters from the main channel, and the scour of eddy return-current channels along the bank where the habitat occurs. Because of this greater relief on the sandbars, backwaters were present across a broader range of flows following the HFE than before the experiment. Reworking of sandbars during diurnal fluctuating flow operations in the first 6 months following the HFE caused sandbar erosion and a reduction of backwater size and abundance to conditions that were 5 to 14 percent greater than existed before the HFE. In the months following the HFE, erosion of sandbars and deposition in eddy return-current channels caused reductions of backwater area and volume. However, sandbar relief was still greater in October 2008 such that backwaters were present across a broader range of discharges than in February 2008. Topographic analyses of the sandbar and backwater morphologic data collected in this study demonstrate that steady flows are associated with a greater amount of continuously available backwater habitat than fluctuating flows, which result in a greater amount of intermittently available habitat. With the exception of the period immediately following the HFE, backwater habitat in 2008 was greater for steady flows associated with dam operations of relatively lower monthly volume (about 227 m3/s) than steady flows associated with dam operations of higher monthly volume. Similarly, there was greater habitat availability associated with lower monthly volume fluctuating flows (post-HFE through mid-April) compared to higher monthly volume fluctuating flows (after mid-April 2008). The sites monitored for this study represent about 20 percent of the 569 estimated number of potential sand-bounded backwaters that occur in eddies below Glen Canyon Dam in Grand Canyon National Park. Data from fish sampling in backwaters, by seining, demonstrates that both native and nonnative species were present in the backwaters monitored for this study.

  17. FLOW-i ventilator performance in the presence of a circle system leak.

    PubMed

    Lucangelo, Umberto; Ajčević, Miloš; Accardo, Agostino; Borelli, Massimo; Peratoner, Alberto; Comuzzi, Lucia; Zin, Walter A

    2017-04-01

    Recently, the FLOW-i anaesthesia ventilator was developed based on the SERVO-i intensive care ventilator. The aim of this study was to test the FLOW-i's tidal volume delivery in the presence of a leak in the breathing circuit. We ventilated a test lung model in volume-, pressure-, and pressure-regulated volume-controlled modes (VC, PC, and PRVC, respectively) with a FLOW-i. First, the circuit remained airtight and the ventilator was tested with fresh gas flows of 6, 1, and 0.3 L/min in VC, PC, and PRVC modes and facing 4 combinations of different resistive and elastic loads. Second, a fixed leak in the breathing circuit was introduced and the measurements repeated. In the airtight system, FLOW-i maintained tidal volume (VT) and circuit pressure at approximately the set values, independently of respiratory mode, load, or fresh gas flow. In the leaking circuit, set VT = 500 mL, FLOW-i delivered higher VTs in PC (about 460 mL) than in VC and PRVC, where VTs were substantially less than 500 mL. Interestingly, VT did not differ appreciably from 6 to 0.3 L/min of fresh air flow among the 3 ventilatory modes. In the absence of leakage, peak inspiratory pressures were similar, while they were 35-45 % smaller in PRVC and VC than in PC mode in the presence of leaks. In conclusion, FLOW-i maintained VT (down to fresh gas flows of 0.3 L/min) to 90 % of its preset value in PC mode, which was 4-5 times greater than in VC or PRVC modes.

  18. Assessment of volume and leak measurements during CPAP using a neonatal lung model.

    PubMed

    Fischer, H S; Roehr, C C; Proquitté, H; Wauer, R R; Schmalisch, G

    2008-01-01

    Although several commercial devices are available which allow tidal volume and air leak monitoring during continuous positive airway pressure (CPAP) in neonates, little is known about their measurement accuracy and about the influence of air leaks on volume measurement. The aim of this in vitro study was the validation of volume and leak measurement under CPAP using a commercial ventilatory device, taking into consideration the clinical conditions in neonatology. The measurement accuracy of the Leoni ventilator (Heinen & Löwenstein, Germany) was investigated both in a leak-free system and with leaks simulated using calibration syringes (2-10 ml, 20-100 ml) and a mechanical lung model. Open tubes of variable lengths were connected for leak simulation. Leak flow was measured with the flow-through technique. In a leak-free system the mean relative volume error +/-SD was 3.5 +/- 2.6% (2-10 ml) and 5.9 +/- 0.7% (20-60 ml), respectively. The influence of CPAP level, driving flow, respiratory rate and humidification of the breathing gas on the volume error was negligible. However, an increasing F(i)O(2) caused the measured tidal volume to increase by up to 25% (F(i)O(2) = 1.0). The relative error +/- SD of the leak measurements was -0.2 +/- 11.9%. For leaks > 19%, measured tidal volume was underestimated by more than 10%. In conclusion, the present in vitro study showed that the Leoni allowed accurate volume monitoring under CPAP conditions similar to neonates. Air leaks of up to 90% of patient flow were reliably detected. For an F(i)O(2) > 0.4 and for leaks > 19%, a numerical correction of the displayed volume should be performed.

  19. Incorporating Storm Sewer Exfiltration into SWMM: Proof of Concept

    EPA Science Inventory

    This study evaluates the peak flow and volume reduction achieved by exfiltration from a perforated storm sewer in an urban catchment. There are three related objectives: [1] quantify peak flow and volume reduction; [2] demonstrate adaptability to climate change; and [3] evaluate ...

  20. CADDIS Volume 2. Sources, Stressors and Responses: Flow Alteration

    EPA Pesticide Factsheets

    Introduction to the flow alteration module, when to list flow alteration as a candidate cause, ways to measure flow alteration, simple and detailed conceptual model diagrams for flow alteration, flow alteration module references and literature reviews.

  1. Pulmonary function in men after oxygen breathing at 3.0 ATA for 3.5 h

    NASA Technical Reports Server (NTRS)

    Clark, J. M.; Jackson, R. M.; Lambertsen, C. J.; Gelfand, R.; Hiller, W. D. B.; Unger, M.

    1991-01-01

    A complete description of pulmonary measurements obtained after continuous O2 exposure of 13 healthy men at 3.0 ATA for 3.5 h is presented. Measurements included flow-volume loops, spirometry, and airway resistance(n = 12); CO diffusing capacity (n = 11); closing volumes (n= 6); and air vs. HeO2 forced vital capacity maneuvers (n = 5). The average difference in maximum mid expiratory flows at 50 percent vital capacity on air and HeO2 was found to be significantly reduced postexposure by 18 percent. Raw and CO diffusing capacity were not changed postexposure. It is concluded that the relatively large change in forced expiratory flow at 25-75 percent of vital capacity compared with the mean forced expiratory volume in 1 s, the reduction in density dependence of flow, and the normal Raw postexposure are all consistent with flow limitation in peripheral airways as a major cause of the observed reduction in expiratory flow.

  2. Yield Hardening of Electrorheological Fluids in Channel Flow

    NASA Astrophysics Data System (ADS)

    Helal, Ahmed; Qian, Bian; McKinley, Gareth H.; Hosoi, A. E.

    2016-06-01

    Electrorheological fluids offer potential for developing rapidly actuated hydraulic devices where shear forces or pressure-driven flow are present. In this study, the Bingham yield stress of electrorheological fluids with different particle volume fractions is investigated experimentally in wall-driven and pressure-driven flow modes using measurements in a parallel-plate rheometer and a microfluidic channel, respectively. A modified Krieger-Dougherty model can be used to describe the effects of the particle volume fraction on the yield stress and is in good agreement with the viscometric data. However, significant yield hardening in pressure-driven channel flow is observed and attributed to an increase and eventual saturation of the particle volume fraction in the channel. A phenomenological physical model linking the densification and consequent microstructure to the ratio of the particle aggregation time scale compared to the convective time scale is presented and used to predict the enhancement in yield stress in channel flow, enabling us to reconcile discrepancies in the literature between wall-driven and pressure-driven flows.

  3. In Vivo Validation of Volume Flow Measurements of Pulsatile Flow Using a Clinical Ultrasound System and Matrix Array Transducer.

    PubMed

    Hudson, John M; Williams, Ross; Milot, Laurent; Wei, Qifeng; Jago, James; Burns, Peter N

    2017-03-01

    The goal of this study was to evaluate the accuracy of a non-invasive C-plane Doppler estimation of pulsatile blood flow in the lower abdominal vessels of a porcine model. Doppler ultrasound measurements from a matrix array transducer system were compared with invasive volume flow measurements made on the same vessels with a surgically implanted ultrasonic transit-time flow probe. For volume flow rates ranging from 60 to 750 mL/min, agreement was very good, with a Pearson correlation coefficient of 0.97 (p < 0.0001) and a mean bias of -4.2%. The combination of 2-D matrix array technology and fast processing gives this Doppler method clinical potential, as many of the user- and system-dependent parameters of previous methods, including explicit vessel angle and diameter measurements, are eliminated. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  4. Topographic Effects on Geologic Mass Movements

    NASA Technical Reports Server (NTRS)

    Baloga, Stephen M.; Frey, Herbert (Technical Monitor)

    2000-01-01

    This report describes research directed toward understanding the response of volcanic lahars and lava flows to changes in the topography along the path of the flow. We have used a variety of steady-state and time-dependent models of lahars and lava flows to calculate the changes in flow dynamics due to variable topography. These models are based on first-order partial differential equations for the local conservation of volume. A global volume conservation requirement is also imposed to determine the extent of the flow as a function of time and the advance rate. Simulated DEMs have been used in this report.

  5. Methods for the Emergency Assessment of Debris-Flow Hazards from Basins Burned by the Fires of 2007, Southern California

    USGS Publications Warehouse

    Cannon, Susan H.; Gartner, Joseph E.; Michael, John A.

    2007-01-01

    This report describes the approach used to assess potential debris-flow hazards from basins burned by the Buckweed, Santiago, Canyon, Poomacha, Ranch, Harris, Witch, Rice, Ammo, Slide, Grass Valley and Cajon Fires of 2007 in southern California. The assessments will be presented as a series of maps showing a relative ranking of the predicted volume of debris flows that can issue from basin outlets in response to a 3-hour duration rainstorm with a 10-year return period. Potential volumes of debris flows are calculated using a multiple-regression model that describes debris-flow volume at a basin outlet as a function of measures of basin gradient, burn extent, and storm rainfall. This assessment provides critical information for issuing basin-specific warnings, locating and designing mitigation measures, and planning of evacuation timing and routes.

  6. Regional blood flow volume in the eustachian tube.

    PubMed

    Minami, T; Kubo, N; Tomoda, K; Yamashita, T; Kumazawa, T

    1993-01-01

    Measurements of regional blood flow around the pharyngeal orifice of the Eustachian tube were carried out after topical administration of various inflammatory mediators in 14 mongrel dogs by the hydrogen clearance method. Histamine and platelet-activating factor (PAF) resulted in a significant alteration of blood flow volume. Histamine was found to induce a dose-response related increase, whereas blood flow volume tended to decrease in each concentration range in the series of PAF administration. There was no significant difference in blood flow between topical application of leukotriene C4 and leukotriene D4. It is likely that in upper respiratory tract inflammation, such as in otitis media and in nasal allergy, activated histamine and PAF affect the microcirculation of the tubal orifice. These results suggest that disturbance of the microcirculatory system in the Eustachian tube mucosa could be involved in the pathogenesis of chronic otitis media with effusion.

  7. Entrance-length dendritic plate heat exchangers

    DOE PAGES

    Bejan, A.; Alalaimi, M.; Sabau, A. S.; ...

    2017-07-17

    We explore the idea that the highest heat transfer rate between two fluids in a given volume is achieved when plate channel lengths are given by the thermal entrance length, i.e., when the thermal boundary layers meet at the exit of each channel. The overall design can be thought of an elemental construct of a dendritic heat exchanger, which consists of two tree-shaped streams arranged in cross flow. Every channel is as long as the thermal entrance length of the developing flow that resides in that channel. The results indicate that the overall design will change with the total volumemore » and total number of channels. We found that the lengths of the surfaces swept in cross flow would have to decrease sizably as number of channels increases, while exhibiting mild decreases as total volume increases. The aspect ratio of each surface swept by fluid in cross flow should be approximately square, independent of total number of channels and volume. We also found that the minimum pumping power decreases sensibly as the total number of channels and the volume increase. FurtherThe maximized heat transfer rate per unit volume increases sharply as the total volume decreases, in agreement with the natural evolution toward miniaturization in technology.« less

  8. Entrance-length dendritic plate heat exchangers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bejan, A.; Alalaimi, M.; Sabau, A. S.

    We explore the idea that the highest heat transfer rate between two fluids in a given volume is achieved when plate channel lengths are given by the thermal entrance length, i.e., when the thermal boundary layers meet at the exit of each channel. The overall design can be thought of an elemental construct of a dendritic heat exchanger, which consists of two tree-shaped streams arranged in cross flow. Every channel is as long as the thermal entrance length of the developing flow that resides in that channel. The results indicate that the overall design will change with the total volumemore » and total number of channels. We found that the lengths of the surfaces swept in cross flow would have to decrease sizably as number of channels increases, while exhibiting mild decreases as total volume increases. The aspect ratio of each surface swept by fluid in cross flow should be approximately square, independent of total number of channels and volume. We also found that the minimum pumping power decreases sensibly as the total number of channels and the volume increase. FurtherThe maximized heat transfer rate per unit volume increases sharply as the total volume decreases, in agreement with the natural evolution toward miniaturization in technology.« less

  9. Cine phase-contrast MRI evaluation of normal aqueductal cerebrospinal fluid flow according to sex and age.

    PubMed

    Unal, Ozkan; Kartum, Alp; Avcu, Serhat; Etlik, Omer; Arslan, Halil; Bora, Aydin

    2009-12-01

    The aim of this study was cerebrospinal flow quantification in the cerebral aqueduct using cine phase-contrast magnetic resonance imaging (MRI) technique in both sexes and five different age groups to provide normative data. Sixty subjects with no cerebral pathology were included in this study. Subjects were divided into five age groups: < or =14 years, 15-24 years, 25-34 years, 35-44 years, and > or =45 years. Phase, rephase, and magnitude images were acquired by 1.5 T MR unit at the level of cerebral aqueduct with spoiled gradient echo through-plane, which is a cine phase-contrast sequence. At this level, peak flow velocity (cm/s), average flow rate (cm/ s), average flow (L/min), volumes in cranial and caudal directions (mL), and net volumes (mL) were studied. There was a statistically significant difference in peak flow between the age group of < or =14 years and the older age groups. There were no statistically significant differences in average velocity, cranial and caudal volume, net volume, and average flow parameters among different age groups. Statistically significant differences were not detected in flow parameters between sexes. When using cine-phase contrast MRI in the cerebral aqueduct, only the peak velocity showed a statistically significant difference between age groups; it was higher in subjects aged < or =14 years than those in older age groups. When performing age-dependent clinical studies including adolescents, this should be taken into consideration.

  10. On viscoelastic cavitating flows: A numerical study

    NASA Astrophysics Data System (ADS)

    Naseri, Homa; Koukouvinis, Phoevos; Malgarinos, Ilias; Gavaises, Manolis

    2018-03-01

    The effect of viscoelasticity on turbulent cavitating flow inside a nozzle is simulated for Phan-Thien-Tanner (PTT) fluids. Two different flow configurations are used to show the effect of viscoelasticity on different cavitation mechanisms, namely, cloud cavitation inside a step nozzle and string cavitation in an injector nozzle. In incipient cavitation condition in the step nozzle, small-scale flow features including cavitating microvortices in the shear layer are suppressed by viscoelasticity. Flow turbulence and mixing are weaker compared to the Newtonian fluid, resulting in suppression of microcavities shedding from the cavitation cloud. Moreover, mass flow rate fluctuations and cavity shedding frequency are reduced by the stabilizing effect of viscoelasticity. Time averaged values of the liquid volume fraction show that cavitation formation is strongly suppressed in the PTT viscoelastic fluid, and the cavity cloud is pushed away from the nozzle wall. In the injector nozzle, a developed cloud cavity covers the nozzle top surface, while a vortex-induced string cavity emerges from the turbulent flow inside the sac volume. Similar to the step nozzle case, viscoelasticity reduces the vapor volume fraction in the cloud region. However, formation of the streamwise string cavity is stimulated as turbulence is suppressed inside the sac volume and the nozzle orifice. Vortical perturbations in the vicinity of the vortex are damped, allowing more vapor to develop in the string cavity region. The results indicate that the effect of viscoelasticity on cavitation depends on the alignment of the cavitating vortices with respect to the main flow direction.

  11. Effects of hypoxia on cochlear blood flow in mice evaluated using Doppler optical microangiography.

    PubMed

    Dziennis, Suzan; Reif, Roberto; Zhi, Zhongwei; Nuttall, Alfred L; Wang, Ruikang K

    2012-10-01

    Reduced cochlear blood flow (CoBF) is a main contributor to hearing loss. Studying CoBF has remained a challenge due to the lack of available tools. Doppler optical microangiography (DOMAG), a method to quantify single-vessel absolute blood flow, and laser Doppler flowmetry (LDF), a method for measuring the relative blood flow within a large volume of tissue, were used for determining the changes in CoBF due to systemic hypoxia in mice. DOMAG determined the change in blood flow in the apical turn (AT) with single-vessel resolution, while LDF averaged the change in the blood flow within a large volume of the cochlea (hemisphere with ∼1 to 1.5 mm radius). Hypoxia was induced by decreasing the concentration of oxygen-inspired gas, so that the oxygen saturation was reduced from >95% to ∼80%. DOMAG determined that during hypoxia the blood flow in two areas of the AT near and far from the helicotrema were increased and decreased, respectively. The LDF detected a decrease in blood flow within a larger volume of the cochlea (several turns averaged together). Therefore, the use of DOMAG as a tool for studying cochlear blood flow due to its ability to determine absolute flow values with single-vessel resolution was proposed.

  12. Effects of hypoxia on cochlear blood flow in mice evaluated using Doppler optical microangiography

    NASA Astrophysics Data System (ADS)

    Dziennis, Suzan; Reif, Roberto; Zhi, Zhongwei; Nuttall, Alfred L.; Wang, Ruikang K.

    2012-10-01

    Reduced cochlear blood flow (CoBF) is a main contributor to hearing loss. Studying CoBF has remained a challenge due to the lack of available tools. Doppler optical microangiography (DOMAG), a method to quantify single-vessel absolute blood flow, and laser Doppler flowmetry (LDF), a method for measuring the relative blood flow within a large volume of tissue, were used for determining the changes in CoBF due to systemic hypoxia in mice. DOMAG determined the change in blood flow in the apical turn (AT) with single-vessel resolution, while LDF averaged the change in the blood flow within a large volume of the cochlea (hemisphere with ˜1 to 1.5 mm radius). Hypoxia was induced by decreasing the concentration of oxygen-inspired gas, so that the oxygen saturation was reduced from >95% to ˜80%. DOMAG determined that during hypoxia the blood flow in two areas of the AT near and far from the helicotrema were increased and decreased, respectively. The LDF detected a decrease in blood flow within a larger volume of the cochlea (several turns averaged together). Therefore, the use of DOMAG as a tool for studying cochlear blood flow due to its ability to determine absolute flow values with single-vessel resolution was proposed.

  13. Simulation of streamflow, evapotranspiration, and groundwater recharge in the Lower Frio River watershed, south Texas, 1961-2008

    USGS Publications Warehouse

    Lizarraga, Joy S.; Ockerman, Darwin J.

    2011-01-01

    The U.S. Geological Survey, in cooperation with the U.S. Army Corps of Engineers, Fort Worth District; the City of Corpus Christi; the Guadalupe-Blanco River Authority; the San Antonio River Authority; and the San Antonio Water System, configured, calibrated, and tested a watershed model for a study area consisting of about 5,490 mi2 of the Frio River watershed in south Texas. The purpose of the model is to contribute to the understanding of watershed processes and hydrologic conditions in the lower Frio River watershed. The model simulates streamflow, evapotranspiration (ET), and groundwater recharge by using a numerical representation of physical characteristics of the landscape, and meteorological and streamflow data. Additional time-series inputs to the model include wastewater-treatment-plant discharges, surface-water withdrawals, and estimated groundwater inflow from Leona Springs. Model simulations of streamflow, ET, and groundwater recharge were done for various periods of record depending upon available measured data for input and comparison, starting as early as 1961. Because of the large size of the study area, the lower Frio River watershed was divided into 12 subwatersheds; separate Hydrological Simulation Program-FORTRAN models were developed for each subwatershed. Simulation of the overall study area involved running simulations in downstream order. Output from the model was summarized by subwatershed, point locations, reservoir reaches, and the Carrizo-Wilcox aquifer outcrop. Four long-term U.S. Geological Survey streamflow-gaging stations and two short-term streamflow-gaging stations were used for streamflow model calibration and testing with data from 1991-2008. Calibration was based on data from 2000-08, and testing was based on data from 1991-99. Choke Canyon Reservoir stage data from 1992-2008 and monthly evaporation estimates from 1999-2008 also were used for model calibration. Additionally, 2006-08 ET data from a U.S. Geological Survey meteorological station in Medina County were used for calibration. Streamflow and ET calibration were considered good or very good. For the 2000-08 calibration period, total simulated flow volume and the flow volume of the highest 10 percent of simulated daily flows were calibrated to within about 10 percent of measured volumes at six U.S. Geological Survey streamflow-gaging stations. The flow volume of the lowest 50 percent of daily flows was not simulated as accurately but represented a small percent of the total flow volume. The model-fit efficiency for the weekly mean streamflow during the calibration periods ranged from 0.60 to 0.91, and the root mean square error ranged from 16 to 271 percent of the mean flow rate. The simulated total flow volumes during the testing periods at the long-term gaging stations exceeded the measured total flow volumes by approximately 22 to 50 percent at three stations and were within 7 percent of the measured total flow volumes at one station. For the longer 1961-2008 simulation period at the long-term stations, simulated total flow volumes were within about 3 to 18 percent of measured total flow volumes. The calibrations made by using Choke Canyon reservoir volume for 1992-2008, reservoir evaporation for 1999-2008, and ET in Medina County for 2006-08, are considered very good. Model limitations include possible errors related to model conceptualization and parameter variability, lack of data to better quantify certain model inputs, and measurement errors. Uncertainty regarding the degree to which available rainfall data represent actual rainfall is potentially the most serious source of measurement error. A sensitivity analysis was performed for the Upper San Miguel subwatershed model to show the effect of changes to model parameters on the estimated mean recharge, ET, and surface runoff from that part of the Carrizo-Wilcox aquifer outcrop. Simulated recharge was most sensitive to the changes in the lower-zone ET (LZ

  14. US researchers study effectiveness of Fluidized Sand Biofilters

    USDA-ARS?s Scientific Manuscript database

    Intensive aquaculture facilities generally produce two separate waste flows: 1) a high volume dilute discharge from culture tanks or pump sumps, and 2) a moderately small and solids-concentrated discharge typically backwashed from mechanical filtration units. The high volume dilute flow can appear p...

  15. Solar receiver protection means and method for loss of coolant flow

    DOEpatents

    Glasgow, Lyle E.

    1983-01-01

    An apparatus and method for preventing a solar receiver (12) utilizing a flowing coolant liquid for removing heat energy therefrom from overheating after a loss of coolant flow. Solar energy is directed to the solar receiver (12) by a plurality of reflectors (16) which rotate so that they direct solar energy to the receiver (12) as the earth rotates. The apparatus disclosed includes a first storage tank (30) for containing a first predetermined volume of the coolant and a first predetermined volume of gas at a first predetermined pressure. The first storage tank (30) includes an inlet and outlet through which the coolant can enter and exit. The apparatus also includes a second storage tank (34) for containing a second predetermined volume of the coolant and a second predetermined volume of the gas at a second predetermined pressure, the second storage tank (34) having an inlet through which the coolant can enter. The first and second storage tanks (30) and (34) are in fluid communication with each other through the solar receiver (12). The first and second predetermined coolant volumes, the first and second gas volumes, and the first and second predetermined pressures are chosen so that a predetermined volume of the coolant liquid at a predetermined rate profile will flow from the first storage tank (30) through the solar receiver (12) and into the second storage tank (34). Thus, in the event of a power failure so that coolant flow ceases and the solar reflectors (16) stop rotating, a flow rate maintained by the pressure differential between the first and second storage tanks (30) and (34) will be sufficient to maintain the coolant in the receiver (12) below a predetermined upper temperature until the solar reflectors (16) become defocused with respect to the solar receiver (12) due to the earth's rotation.

  16. Increased hippocampal blood volume and normal blood flow in schizophrenia

    PubMed Central

    Talati, Pratik; Rane, Swati; Skinner, Jack; Gore, John; Heckers, Stephan

    2015-01-01

    Neuroimaging studies have provided compelling evidence for abnormal hippocampal activity in schizophrenia. Most studies made inferences about baseline hippocampal activity using a single hemodynamic parameter (e.g., blood volume or blood flow). Here we studied several hemodynamic measures in the same cohort to test the hypothesis of increased hippocampal activity in schizophrenia. We used dynamic susceptibility contrast- (DSC-) magnetic resonance imaging to assess blood volume, blood flow, and mean transit time in the hippocampus of 15 patients with chronic schizophrenia and 15 healthy controls. Left and right hippocampal measurements were combined for absolute measures of cerebral blood volume (CBV), blood flow (CBF), and mean transit time (MTT). We found significantly increased hippocampal CBV, but normal CBF and MTT, in schizophrenia. The uncoupling of CBV and CBF could be due to several factors, including antipsychotic medication, loss of cerebral perfusion pressure, or angiogenesis. Further studies need to incorporate several complementary imaging modalities to better characterize hippocampal dysfunction in schizophrenia. PMID:25896442

  17. Interstitial solute transport in 3D reconstructed neuropil occurs by diffusion rather than bulk flow.

    PubMed

    Holter, Karl Erik; Kehlet, Benjamin; Devor, Anna; Sejnowski, Terrence J; Dale, Anders M; Omholt, Stig W; Ottersen, Ole Petter; Nagelhus, Erlend Arnulf; Mardal, Kent-André; Pettersen, Klas H

    2017-09-12

    The brain lacks lymph vessels and must rely on other mechanisms for clearance of waste products, including amyloid [Formula: see text] that may form pathological aggregates if not effectively cleared. It has been proposed that flow of interstitial fluid through the brain's interstitial space provides a mechanism for waste clearance. Here we compute the permeability and simulate pressure-mediated bulk flow through 3D electron microscope (EM) reconstructions of interstitial space. The space was divided into sheets (i.e., space between two parallel membranes) and tunnels (where three or more membranes meet). Simulation results indicate that even for larger extracellular volume fractions than what is reported for sleep and for geometries with a high tunnel volume fraction, the permeability was too low to allow for any substantial bulk flow at physiological hydrostatic pressure gradients. For two different geometries with the same extracellular volume fraction the geometry with the most tunnel volume had [Formula: see text] higher permeability, but the bulk flow was still insignificant. These simulation results suggest that even large molecule solutes would be more easily cleared from the brain interstitium by diffusion than by bulk flow. Thus, diffusion within the interstitial space combined with advection along vessels is likely to substitute for the lymphatic drainage system in other organs.

  18. Rheological Characterisation of the Flow Behaviour of Wood Plastic Composites in Consideration of Different Volume Fractions of Wood

    NASA Astrophysics Data System (ADS)

    Laufer, N.; Hansmann, H.; Koch, M.

    2017-01-01

    In this study, the rheological properties of wood plastic composites (WPC) with different polymeric matrices (LDPE, low-density polyethylene and PP, polypropylene) and with different types of wood filler (hardwood flour and softwood flour) have been investigated by means of high pressure capillary rheometry. The volume fraction of wood was varied between 0 and 60 %. The shear thinning behaviour of the WPC melts can be well described by the Ostwald - de Waele power law relationship. The flow consistency index K of the power law shows a good correlation with the volume fraction of wood. Interparticular interaction effects of wood particles can be mathematically taken into account by implementation of an interaction exponent (defined as the ratio between flow exponent of WPC and flow exponent of polymeric matrix). The interaction exponent shows a good correlation with the flow consistency index. On the basis of these relationships the concept of shear-stress-equivalent inner shear rate has been modified. Thus, the flow behaviour of the investigated wood filled polymer melts could be well described mathematically by the modified concept of shear-stress-equivalent inner shear rate. On this basis, the shear thinning behaviour of WPC can now be estimated with good accuracy, taking into account the volume fraction of wood.

  19. Photon activation-15O decay studies of tumor blood flow.

    PubMed

    Ten Haken, R K; Nussbaum, G H; Emami, B; Hughes, W L

    1981-01-01

    A direct, noninvasive method for measuring absolute values of specific capillary blood flow in living tissue is described. The method is based on the photon activation, in situ, of tissue elements and the measurement of the subsequent decay of the positron activity induced, employing coincidence detection of the photon pairs produced in positron annihilation. Analysis of the time-dependent coincidence spectrum reveals the contribution to the total signal from the decay of 15O, from which the specific capillary blood flow in the imaged, activated volume is ultimately determined. By virtue of its introduction of the radioisotope of interest (15O) directly and uniformly into the tissue volume under investigation, the method described permits both the nonperfused and well perfused fractions of an activated volume to be estimated and hence, the average specific blood flow within imaged tumor volumes to be computed. The model employed to describe and analyze the data is discussed in detail. Results of application of the technique to measurement of specific blood flow in rhabdomyosarcoma tumors grown in WAG/Rij rats are presented and discussed. The method is shown to be reliable and well suited to studies designed to determined the effects of various agents, such as heat, radiation and drugs, on tumor blood flow.

  20. Packaged peristaltic micropump for controlled drug delivery application

    NASA Astrophysics Data System (ADS)

    Vinayakumar, K. B.; Nadiger, Girish; R. Shetty, Vikas; Dinesh, N. S.; Nayak, M. M.; Rajanna, K.

    2017-01-01

    Micropump technology has evolved significantly in the last two decades and is finding a variety of applications ranging from μTAS (micro Total Analysis System) to drug delivery. However, the application area of the micropump is limited owing to: simple pumping mechanism, ease of handling, controlled (microliter to milliliter) delivery, continuous delivery, and accuracy in flow rate. Here, the author presents the design, development, characterization, and precision flow controlling of a DC-motor driven peristaltic pump for controlled drug delivery application. All the micropump components were fabricated using the conventional fabrication technique. The volume flow variation of the pump has been characterized for different viscous fluids. The change in volume flow due to change in back pressure has been presented in detail. The fail-safe mode operation of the pump has been tested and leak rate was measured (˜0.14% leak for an inlet pressure of 140 kPa) for different inlet pressures. The precision volume flow of the pump has been achieved by measuring the pinch cam position and load current. The accuracy in the volume flow has been measured after 300 rotations. Finally, the complete system has been integrated with the necessary electronics and an android application has been developed for the self-administration of bolus and basal delivery of insulin.

  1. A model of hydraulic interactions in liver parenchyma as forces behind the intrahepatic bile flow.

    PubMed

    Kurbel, S; Kurbel, B; Dmitrovic, B; Wagner, J

    2001-05-01

    The small diameters of bile canaliculi and interlobular bile ducts make it hard to attribute the bile flow solely to the process of secretion. In the model liver within its capsule is considered a limited space in which volume expansions of one part are possible only through the shrinking of other parts. The liver capsule allows only very slow volume changes. The rate of blood flow through the sinusoides is governed by the Poisseuill-Hagen law. The model is based on a concept of circulatory liver units. A unit would contain a group of acini sharing the same conditions of arterial flow. We can imagine them as an acinar group behind the last pressure reducer on one arterial branch. Acini from neighboring units compose liver lobules and drain through the same central venule. One lobule can contain acini from several neighboring circulatory units. The perfusion cycle in one unit begins with a transient tide in the arterial flow, governed by local mediators. Corresponding acini expand, grabbing the space by compressing their neighbors in the same lobules. Vascular resistance is reduced in dilated and increased in compressed acini. Portal blood flows through the dilated acini, bypassing the compressed neighbors. The cycle ends when the portal tide slowly diminishes and acinar volume is back on the interphase value until the new perfusion cycle is started in another circulatory unit. Each cycle probably takes minutes to complete. Increased pressures both in dilated and in compressed acini force the bile to move from acinar canalicules. Both up and down changes in acinar volume might force the acinar biliary flow. In cases of arterial vasoconstriction, increased activity of vasoactive substances would keep most of the circulatory units in the interphase and increased liver resistance can be expected. Liver fibrosis makes all acini to be of fixed volume and result in increased resistance. Because of that, low pressure portal flow would be more compromised, as reported. In livers without arterial blood flow, although some slow changes in the portal flows can be expected, acinar volume changes should be reduced. In acute liver injury, enlarged hepatocytes would diminish sinusoidal diameter and increase acinar resistance. In liver tumors, areas of neovascularization with reduced resistance would divert the arterial flow from the normal tissue, while in the compressed perifocal areas, increased vascular resistance should diminish mainly the portal flow. Copyright 2001 Harcourt Publishers Ltd.

  2. Changes in the timing of high river flows in New England over the 20th Century

    USGS Publications Warehouse

    Hodgkins, G.A.; Dudley, R.W.; Huntington, T.G.

    2003-01-01

    The annual timing of river flows is a good indicator of climate-related changes, or lack of changes, for rivers with long-term data that drain unregulated basins with stable land use. Changes in the timing of annual winter/spring (January 1 to May 31) and fall (October 1 to December 31) center of volume dates were analyzed for 27 rural, unregulated river gaging stations in New England, USA with an average of 68 years of record. The center of volume date is the date by which half of the total volume of water for a given period of time flows past a river gaging station, and is a measure of the timing of the bulk of flow within the time period. Winter/spring center of volume (WSCV) dates have become significantly earlier (p < 0.1) at all 11 river gaging stations in areas of New England where snowmelt runoff has the most effect on spring river flows. Most of this change has occurred in the last 30 years with dates advancing by 1-2 weeks. WSCV dates were correlated with March through April air temperatures (r = -0.72) and with January precipitation (r = -0.37). Three of 16 river gaging stations in the remainder of New England had significantly earlier WSCV dates. Four out of 27 river gaging stations had significantly earlier fall center of volume dates in New England. Changes in the timing of winter/spring and fall peak flow dates were consistent with the changes in the respective center of volume dates, given the greater variability in the peak flow dates. Changes in the WSCV dates over the last 30 years are consistent with previous studies of New England last-frost dates, lilac bloom dates, lake ice-out dates, and spring air temperatures. This suggests that these New England spring geophysical and biological changes all were caused by a common mechanism, temperature increases.

  3. The assessment of circulating volume using inferior vena cava collapse index and carotid Doppler velocity time integral in healthy volunteers: a pilot study.

    PubMed

    Peachey, Tom; Tang, Andrew; Baker, Elinor C; Pott, Jason; Freund, Yonathan; Harris, Tim

    2016-09-02

    Assessment of circulating volume and the requirement for fluid replacement are fundamental to resuscitation but remain largely empirical. Passive leg raise (PLR) may determine fluid responders while avoiding potential fluid overload. We hypothesised that inferior vena cava collapse index (IVCCI) and carotid artery blood flow would change predictably in response to PLR, potentially providing a non-invasive tool to assess circulating volume and identifying fluid responsive patients. We conducted a prospective proof of concept pilot study on fasted healthy volunteers. One operator measured IVC diameter during quiet respiration and sniff, and carotid artery flow. Stroke volume (SV) was also measured using suprasternal Doppler. Our primary endpoint was change in IVCCI after PLR. We also studied changes in IVCCI after "sniff", and correlation between carotid artery flow and SV. Passive leg raise was associated with significant reduction in the mean inferior vena cava collapsibility index from 0.24 to 0.17 (p < 0.01). Mean stroke volume increased from 56.0 to 69.2 mL (p < 0.01). There was no significant change in common carotid artery blood flow. Changes in physiology consequent upon passive leg raise normalised rapidly. Passive leg raise is associated with a decrease of IVCCI and increase in stroke volume. However, the wide range of values observed suggests that factors other than circulating volume predominate in determining the proportion of collapse with respiration. In contrast to other studies, we did not find that carotid blood flow increased with passive leg raise. Rapid normalisation of post-PLR physiology may account for this.

  4. Relationship between pineal cyst size and aqueductal CSF flow measured by phase contrast MRI.

    PubMed

    Bezuidenhout, Abraham F; Kasper, Ekkehard M; Baledent, Olivier; Rojas, Rafael; Bhadelia, Rafeeque A

    2018-02-23

    Most patients with pineal cysts referred for neurosurgical consultation have no specific symptoms or objective findings except for pineal cyst size to help in management decisions. Our purpose was to assess the relationship between pineal cyst size and aqueductal CSF flow using PC-MRI. Eleven adult patients with pineal cysts (> 1-cm in size) referred for neurosurgical consultations were included. Cyst volume was calculated using 3D T1 images. PC-MRI in axial plane with velocity encoding of 5 cm/sec was used to quantitatively assess CSF flow through the cerebral aqueduct to determine the aqueductal stroke volume, which was then correlated to cyst size using Pearson's correlation. Pineal cysts were grouped by size into small (6/11) and large (5/11) using the median value to compare aqueductal stroke volume using Mann-Whitney test. Patients were 39 ± 13 years (mean ± SD) of age, and 10/11 (91%) were female. There was significant negative correlation between cyst volume and aqueductal stroke volume (r=0.74; p=0.009). Volume of small cysts (4954±2157 mm3) was significantly different compared to large cysts (13752±3738 mm3; p= 0.008). The aqueductal stroke volume of patients harboring large cysts 33±8 μL/cardiac cycle was significantly lower than that of patients with small cysts 96±29 μL/cardiac cycle (p=0.008). Aqueductal CSF flow appears to decrease with increasing pineal cyst size. Our preliminary results provide first evidence that even in the absence of objective neurological findings or hydrocephalus; larger pineal cysts already display decreased CSF flow through the cerebral aqueduct.

  5. Short-time-scale left ventricular systolic dynamics. Evidence for a common mechanism in both left ventricular chamber and heart muscle mechanics.

    PubMed

    Campbell, K B; Shroff, S G; Kirkpatrick, R D

    1991-06-01

    Based on the premise that short-time-scale, small-amplitude pressure/volume/outflow behavior of the left ventricular chamber was dominated by dynamic processes originating in cardiac myofilaments, a prototype model was built to predict pressure responses to volume perturbations. In the model, chamber pressure was taken to be the product of the number of generators in a pressure-bearing state and their average volumetric distortion, as in the muscle theory of A.F. Huxley, in which force was equal to the number of attached crossbridges and their average lineal distortion. Further, as in the muscle theory, pressure generators were assumed to cycle between two states, the pressure-bearing state and the non-pressure-bearing state. Experiments were performed in the isolated ferret heart, where variable volume decrements (0.01-0.12 ml) were removed at two commanded flow rates (flow clamps, -7 and -14 ml/sec). Pressure responses to volume removals were analyzed. Although the prototype model accounted for most features of the pressure responses, subtle but systematic discrepancies were observed. The presence or absence of flow and the magnitude of flow affected estimates of model parameters. However, estimates of parameters did not differ when the model was fitted to flow clamps with similar magnitudes of flows but different volume changes. Thus, prototype model inadequacies were attributed to misrepresentations of flow-related effects but not of volume-related effects. Based on these discrepancies, an improved model was built that added to the simple two-state cycling scheme, a pathway to a third state. This path was followed only in response to volume change. The improved model eliminated the deficiencies of the prototype model and was adequate in accounting for all observations. Since the template for the improved model was taken from the cycling crossbridge theory of muscle contraction, it was concluded that, in spite of the complexities of geometry, architecture, and regional heterogeneity of function and structure, crossbridge mechanisms dominated the short-time-scale dynamics of left ventricular chamber behavior.

  6. Comparison of Flow and Volume Incentive Spirometry on Pulmonary Function and Exercise Tolerance in Open Abdominal Surgery: A Randomized Clinical Trial.

    PubMed

    Kumar, Amaravadi Sampath; Alaparthi, Gopala Krishna; Augustine, Alfred Joseph; Pazhyaottayil, Zulfeequer Chundaanveetil; Ramakrishna, Anand; Krishnakumar, Shyam Krishnan

    2016-01-01

    Surgical procedures in abdominal area lead to changes in pulmonary function, respiratory mechanics and impaired physical capacity leading to postoperative pulmonary complications, which can affect up to 80% of upper abdominal surgery. To evaluate the effects of flow and volume incentive spirometry on pulmonary function and exercise tolerance in patients undergoing open abdominal surgery. A randomized clinical trial was conducted in a hospital of Mangalore city in Southern India. Thirty-seven males and thirteen females who were undergoing abdominal surgeries were included and allocated into flow and volume incentive spirometry groups by block randomization. All subjects underwent evaluations of pulmonary function with measurement of Forced Vital Capacity (FVC), Forced Expiratory Volume in the first second (FEV1), Peak Expiratory Flow (PEF). Preoperative and postoperative measurements were taken up to day 5 for both groups. Exercise tolerance measured by Six- Minute Walk Test during preoperative period and measured again at the time of discharge for both groups. Pulmonary function was analysed by post-hoc analysis and carried out using Bonferroni's 't'-test. Exercise tolerance was analysed by Paired 'T'-test. Pulmonary function (FVC, FEV1, and PEFR) was found to be significantly decreased in 1(st), 2(nd) and 3(rd) postoperative day when compared with preoperative day. On 4(th) and 5(th) postoperative day the pulmonary function (FVC, FEV1, and PEFR) was found to be better preserved in both flow and volume incentive spirometry groups. The Six-Minute Walk Test showed a statistically significant improvement in pulmonary function on the day of discharge than in the preoperative period. In terms of distance covered, the volume- incentive spirometry group showed a greater statistically significant improvement from the preoperative period to the time of discharge than was exhibited by the flow incentive spirometry group. Flow and volume incentive spirometry can be safely recommended to patients undergoing open abdominal surgery as there have been no adverse events recorded. Also, these led to a demonstrable improvement in pulmonary function and exercise tolerance.

  7. Comparison of Flow and Volume Incentive Spirometry on Pulmonary Function and Exercise Tolerance in Open Abdominal Surgery: A Randomized Clinical Trial

    PubMed Central

    Kumar, Amaravadi Sampath; Augustine, Alfred Joseph; Pazhyaottayil, Zulfeequer Chundaanveetil; Ramakrishna, Anand; Krishnakumar, Shyam Krishnan

    2016-01-01

    Introduction Surgical procedures in abdominal area lead to changes in pulmonary function, respiratory mechanics and impaired physical capacity leading to postoperative pulmonary complications, which can affect up to 80% of upper abdominal surgery. Aim To evaluate the effects of flow and volume incentive spirometry on pulmonary function and exercise tolerance in patients undergoing open abdominal surgery. Materials and Methods A randomized clinical trial was conducted in a hospital of Mangalore city in Southern India. Thirty-seven males and thirteen females who were undergoing abdominal surgeries were included and allocated into flow and volume incentive spirometry groups by block randomization. All subjects underwent evaluations of pulmonary function with measurement of Forced Vital Capacity (FVC), Forced Expiratory Volume in the first second (FEV1), Peak Expiratory Flow (PEF). Preoperative and postoperative measurements were taken up to day 5 for both groups. Exercise tolerance measured by Six- Minute Walk Test during preoperative period and measured again at the time of discharge for both groups. Pulmonary function was analysed by post-hoc analysis and carried out using Bonferroni’s ‘t’-test. Exercise tolerance was analysed by Paired ‘T’-test. Results Pulmonary function (FVC, FEV1, and PEFR) was found to be significantly decreased in 1st, 2nd and 3rd postoperative day when compared with preoperative day. On 4th and 5th postoperative day the pulmonary function (FVC, FEV1, and PEFR) was found to be better preserved in both flow and volume incentive spirometry groups. The Six-Minute Walk Test showed a statistically significant improvement in pulmonary function on the day of discharge than in the preoperative period. In terms of distance covered, the volume- incentive spirometry group showed a greater statistically significant improvement from the preoperative period to the time of discharge than was exhibited by the flow incentive spirometry group. Conclusion Flow and volume incentive spirometry can be safely recommended to patients undergoing open abdominal surgery as there have been no adverse events recorded. Also, these led to a demonstrable improvement in pulmonary function and exercise tolerance. PMID:26894090

  8. Effects of debris flow composition on runout, depositional mechanisms, and deposit morphology in laboratory experiments

    NASA Astrophysics Data System (ADS)

    Haas, Tjalling; Braat, Lisanne; Leuven, Jasper R. F. W.; Lokhorst, Ivar R.; Kleinhans, Maarten G.

    2015-09-01

    Predicting debris flow runout is of major importance for hazard mitigation. Apart from topography and volume, runout distance and area depends on debris flow composition and rheology, but how is poorly understood. We experimentally investigated effects of composition on debris flow runout, depositional mechanisms, and deposit geometry. The small-scale experimental debris flows were largely similar to natural debris flows in terms of flow behavior, deposit morphology, grain size sorting, channel width-depth ratio, and runout. Deposit geometry (lobe thickness and width) in our experimental debris flows is largely determined by composition, while the effects of initial conditions of topography (i.e., outflow plain slope and channel slope and width) and volume are negligible. We find a clear optimum in the relations of runout with coarse-material fraction and clay fraction. Increasing coarse-material concentration leads to larger runout. However, excess coarse material results in a large accumulation of coarse debris at the flow front and enhances diffusivity, increasing frontal friction and decreasing runout. Increasing clay content initially enhances runout, but too much clay leads to very viscous flows, reducing runout. Runout increases with channel slope and width, outflow plain slope, debris flow volume, and water fraction. These results imply that debris flow runout depends at least as much on composition as on topography. This study improves understanding of the effects of debris flow composition on runout and may aid future debris flow hazard assessments.

  9. Gaseous oxygen uptake in porous media at different moisture contents and airflow velocities.

    PubMed

    Sharma, Prabhakar; Poulsen, Tjalfe G; Kalluri, Prasad N V

    2009-06-01

    The presence and distribution of water in the pore space is a critical factor for flow and transport of gases through unsaturated porous media. The water content also affects the biological activity necessary for treatment of polluted gas streams in biofilters. In this research, microbial activity and quantity of inactive volume in a porous medium as a function of moisture content and gas flow rate were investigated. Yard waste compost was used as a test medium, and oxygen uptake rate measurements were used to quantify microbial activity and effective active compost volume using batch and column flow-through systems. Compost water contents were varied from air-dry to field capacity and gas flows ranged from 0.2 to 2 L x min(-1). The results showed that overall microbial activity and the relative fraction of active compost medium volume increased with airflow velocity for all levels of water content up to a certain flow rate above which the oxygen uptake rate assumed a constant value independent of gas flow. The actual value of the maximum oxygen uptake rate was controlled by the water content. The oxygen uptake rate also increased with increasing water content and reached a maximum between 42 and 48% volumetric water content, above which it decreased, again likely because of formation of inactive zones in the compost medium. Overall, maximum possible oxygen uptake rate as a function of gas flow rate across all water contents and gas flows could be approximated by a linear expression. The relative fraction of active volume also increased with gas flow rate and reached approximately 80% for the highest gas flows used.

  10. Constructal vascularized structures

    NASA Astrophysics Data System (ADS)

    Cetkin, Erdal

    2015-06-01

    Smart features such as self-healing and selfcooling require bathing the entire volume with a coolant or/and healing agent. Bathing the entire volume is an example of point to area (or volume) flows. Point to area flows cover all the distributing and collecting kinds of flows, i.e. inhaling and exhaling, mining, river deltas, energy distribution, distribution of products on the landscape and so on. The flow resistances of a point to area flow can be decreased by changing the design with the guidance of the constructal law, which is the law of the design evolution in time. In this paper, how the flow resistances (heat, fluid and stress) can be decreased by using the constructal law is shown with examples. First, the validity of two assumptions is surveyed: using temperature independent Hess-Murray rule and using constant diameter ducts where the duct discharges fluid along its edge. Then, point to area types of flows are explained by illustrating the results of two examples: fluid networks and heating an area. Last, how the structures should be vascularized for cooling and mechanical strength is documented. This paper shows that flow resistances can be decreased by morphing the shape freely without any restrictions or generic algorithms.

  11. Simulation of confined magnetohydrodynamic flows with Dirichlet boundary conditions using a pseudo-spectral method with volume penalization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morales, Jorge A.; Leroy, Matthieu; Bos, Wouter J.T.

    A volume penalization approach to simulate magnetohydrodynamic (MHD) flows in confined domains is presented. Here the incompressible visco-resistive MHD equations are solved using parallel pseudo-spectral solvers in Cartesian geometries. The volume penalization technique is an immersed boundary method which is characterized by a high flexibility for the geometry of the considered flow. In the present case, it allows to use other than periodic boundary conditions in a Fourier pseudo-spectral approach. The numerical method is validated and its convergence is assessed for two- and three-dimensional hydrodynamic (HD) and MHD flows, by comparing the numerical results with results from literature and analyticalmore » solutions. The test cases considered are two-dimensional Taylor–Couette flow, the z-pinch configuration, three dimensional Orszag–Tang flow, Ohmic-decay in a periodic cylinder, three-dimensional Taylor–Couette flow with and without axial magnetic field and three-dimensional Hartmann-instabilities in a cylinder with an imposed helical magnetic field. Finally, we present a magnetohydrodynamic flow simulation in toroidal geometry with non-symmetric cross section and imposing a helical magnetic field to illustrate the potential of the method.« less

  12. Sediment Transportation Induced by Deep-Seated Landslides in a Debris Flow Basin in Taiwan

    NASA Astrophysics Data System (ADS)

    Lin, Meei Ling; Chen, Te Wei; Chen, Yong Sheng; Sin Jhuang, Han

    2016-04-01

    Typhoon Morakot brought huge amount of rainfall to the southern Taiwan in 2009 and caused severe landslides and debris flow hazard. After Typhoon Morakot, it was found that the volume of sediment transported by the debris flow and its effects on the affected area were much more significant compared to previous case history, which may due to the huge amount of rainfall causing significant deep-seated landslides in the basin. In this study, the effects and tendency of the sediment transportation in a river basin following deep-seated landslides caused by typhoon Morakot were evaluated. We used LiDAR, DEM, and aerial photo to identify characteristics of deep-seated landslides in a debris flow river basin, KSDF079 in Liuoguey District, Kaohsiung City, Taiwan. Eight deep-seated landslides were identified in the basin. To estimate the potential landslide volume associated with the deep-seated landslides, the stability analysis was conducted to locate the critical sliding surface, and the potential landside volume was estimated based on the estimation equation proposed by the International Geotechnical Societies' UNESCO Working Party on World Landslide Inventory (WP/WLI, 1990). The total potential landslide volume of the eight deep-seated landslides in KSDF079 basin was about 28,906,856 m3. Topographic analysis was performed by using DEM before and LiDAR derived DEM after typhoon Morakot to calculate the landslide volume transported. The result of erosion volume and deposition volume lead to a run out volume of 5,832,433 m3. The results appeared to consist well with the field condition and aerial photo. Comparing the potential landslide volume and run out volume of eight deep-seated landslides, it was found that the remaining potential landslide volume was about 80%. Field investigation and topographic analysis of the KSDF079 debris flow revealed that a significant amount of sediment deposition remained in the river channel ranging from the middle to the downstream section of the channel, and the channel has been widen. Such large proportion of landslide volume remained in the basin on deep-seated landslide scars and debris flow river channel would likely to cause further debris transportation in the future events. The stability analysis used in this study provided a feasible method and satisfactory results for estimating sediment volume transportation associated with the deep-seated landslides in the study area. Combination of the stability analysis results and the topographic analysis provided estimation of sediment transportation caused by the deep-seated landslides, and trend variation of further sediment transport of the basin, which could provide vital information for hazard mitigation. Keyword: deep-seated landslide, sediment transport, DEM, LiDAR, stability analysis

  13. Modeling dam-break flows using finite volume method on unstructured grid

    USDA-ARS?s Scientific Manuscript database

    Two-dimensional shallow water models based on unstructured finite volume method and approximate Riemann solvers for computing the intercell fluxes have drawn growing attention because of their robustness, high adaptivity to complicated geometry and ability to simulate flows with mixed regimes and di...

  14. 40 CFR 146.23 - Operating, monitoring, and reporting requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... pressure, flow rate, and cumulative volume at least with the following frequencies: (i) Weekly for produced..., flow rate and cumulative volume at reasonable intervals no greater than 30 days. (3) A demonstration of..., and any major changes in characteristics or sources of injected fluid. Previously submitted...

  15. Numerical Study of Laminar Flow and Convective Heat Transfer Utilizing Nanofluids in Equilateral Triangular Ducts with Constant Heat Flux

    PubMed Central

    Ting, Hsien-Hung; Hou, Shuhn-Shyurng

    2016-01-01

    This study numerically investigates heat transfer augmentation using water-based Al2O3 and CuO nanofluids flowing in a triangular cross-sectional duct under constant heat flux in laminar flow conditions. The Al2O3/water nanofluids with different volume fractions (0.1%, 0.5%, 1%, 1.5%, and 2%) and CuO/water nanofluids with various volume fractions (0.05%, 0.16%, 0.36%, 0.5%, and 0.8%) are employed, and Reynolds numbers in the range of 700 to 1900 in a laminar flow are considered. The heat transfer rate becomes more remarkable when employing nanofluids. As compared with pure water, at a Peclet number of 7000, a 35% enhancement in the convective heat transfer coefficient, is obtained for an Al2O3/water nanofluid with 2% particle volume fraction; at the same Peclet number, a 41% enhancement in the convective heat transfer coefficient is achieved for a CuO/water nanofluid with 0.8% particle volume concentration. Heat transfer enhancement increases with increases in particle volume concentration and Peclet number. Moreover, the numerical results are found to be in good agreement with published experimental data. PMID:28773698

  16. Expiratory flow limitation and operating lung volumes during exercise in older and younger adults.

    PubMed

    Smith, Joshua R; Kurti, Stephanie P; Meskimen, Kayla; Harms, Craig A

    2017-06-01

    We determined the effect of aging on expiratory flow limitation (EFL) and operating lung volumes when matched for lung size. We hypothesized that older adults will exhibit greater EFL and increases in EELV during exercise compared to younger controls. Ten older (5M/5W; >60years old) and nineteen height-matched young adults (10M/9W) were recruited. Young adults were matched for%predicted forced vital capacity (FVC) (Y-matched%Pred FVC; n=10) and absolute FVC (Y-matched FVC; n=10). Tidal flow-volume loops were recorded during the incremental exercise test with maximal flow-volume loops measured pre- and post-exercise. Compared to younger controls, older adults exhibited more EFL at ventilations of 26, 35, 51, and 80L/min. The older group had higher end-inspiratory lung volume compared to Y-matched%Pred FVC group during submaximal ventilations. The older group increased EELV during exercise, while EELV stayed below resting in the Y-matched%Pred FVC group. These data suggest older adults exhibit more EFL and increase EELV earlier during exercise compared to younger adults. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. CADDIS Volume 2. Sources, Stressors and Responses: Flow Alteration - Simple Conceptual Diagram

    EPA Pesticide Factsheets

    Introduction to the flow alteration module, when to list flow alteration as a candidate cause, ways to measure flow alteration, simple and detailed conceptual model diagrams for flow alteration, flow alteration module references and literature reviews.

  18. CADDIS Volume 2. Sources, Stressors and Responses: Flow Alteration - Detailed Conceptual Diagram

    EPA Pesticide Factsheets

    Introduction to the flow alteration module, when to list flow alteration as a candidate cause, ways to measure flow alteration, simple and detailed conceptual model diagrams for flow alteration, flow alteration module references and literature reviews.

  19. Variational tricomplex of a local gauge system, Lagrange structure and weak Poisson bracket

    NASA Astrophysics Data System (ADS)

    Sharapov, A. A.

    2015-09-01

    We introduce the concept of a variational tricomplex, which is applicable both to variational and nonvariational gauge systems. Assigning this tricomplex with an appropriate symplectic structure and a Cauchy foliation, we establish a general correspondence between the Lagrangian and Hamiltonian pictures of one and the same (not necessarily variational) dynamics. In practical terms, this correspondence allows one to construct the generating functional of a weak Poisson structure starting from that of a Lagrange structure. As a byproduct, a covariant procedure is proposed for deriving the classical BRST charge of the BFV formalism by a given BV master action. The general approach is illustrated by the examples of Maxwell’s electrodynamics and chiral bosons in two dimensions.

  20. BRST symmetry for a torus knot

    NASA Astrophysics Data System (ADS)

    Pandey, Vipul Kumar; Prasad Mandal, Bhabani

    2017-08-01

    We develop BRST symmetry for the first time for a particle on the surface of a torus knot by analyzing the constraints of the system. The theory contains 2nd-class constraints and has been extended by introducing the Wess-Zumino term to convert it into a theory with first-class constraints. BFV analysis of the extended theory is performed to construct BRST/anti-BRST symmetries for the particle on a torus knot. The nilpotent BRST/anti-BRST charges which generate such symmetries are constructed explicitly. The states annihilated by these nilpotent charges consist of the physical Hilbert space. We indicate how various effective theories on the surface of the torus knot are related through the generalized version of the BRST transformation with finite-field-dependent parameters.

  1. Physical Projections in BRST Treatments of Reparametrization Invariant Theories

    NASA Astrophysics Data System (ADS)

    Marnelius, Robert; Sandström, Niclas

    Any regular quantum mechanical system may be cast into an Abelian gauge theory by simply reformulating it as a reparametrization invariant theory. We present a detailed study of the BRST quantization of such reparametrization invariant theories within a precise operator version of BRST which is related to the conventional BFV path integral formulation. Our treatments lead us to propose general rules for how physical wave functions and physical propagators are to be projected from the BRST singlets and propagators in the ghost extended BRST theory. These projections are performed by boundary conditions which are specified by the ingredients of BRST charge and precisely determined by the operator BRST. We demonstrate explicitly the validity of these rules for the considered class of models.

  2. BFV approach to geometric quantization

    NASA Astrophysics Data System (ADS)

    Fradkin, E. S.; Linetsky, V. Ya.

    1994-12-01

    A gauge-invariant approach to geometric quantization is developed. It yields a complete quantum description for dynamical systems with non-trivial geometry and topology of the phase space. The method is a global version of the gauge-invariant approach to quantization of second-class constraints developed by Batalin, Fradkin and Fradkina (BFF). Physical quantum states and quantum observables are respectively described by covariantly constant sections of the Fock bundle and the bundle of hermitian operators over the phase space with a flat connection defined by the nilpotent BVF-BRST operator. Perturbative calculation of the first non-trivial quantum correction to the Poisson brackets leads to the Chevalley cocycle known in deformation quantization. Consistency conditions lead to a topological quantization condition with metaplectic anomaly.

  3. Poisson sigma models, reduction and nonlinear gauge theories

    NASA Astrophysics Data System (ADS)

    Signori, Daniele

    This dissertation comprises two main lines of research. Firstly, we study non-linear gauge theories for principal bundles, where the structure group is replaced by a Lie groupoid. We follow the approach of Moerdijk-Mrcun and establish its relation with the existing physics literature. In particular, we derive a new formula for the gauge transformation which closely resembles and generalizes the classical formulas found in Yang Mills gauge theories. Secondly, we give a field theoretic interpretation of the of the BRST (Becchi-Rouet-Stora-Tyutin) and BFV (Batalin-Fradkin-Vilkovisky) methods for the reduction of coisotropic submanifolds of Poisson manifolds. The generalized Poisson sigma models that we define are related to the quantization deformation problems of coisotropic submanifolds using homotopical algebras.

  4. Further development and testing of the metabolic gas analyzer

    NASA Technical Reports Server (NTRS)

    1973-01-01

    Continued development of a metabolic monitor utilizing a mass spectrometer and digital computer to perform measurements and data reduction, is reported. The device prints-out breath-by-breath values for 02 consumption, C02 production, minute volume and tidal volume. The flow is measured by introduction of a tracer gas to the expired gas stream. Design modifications to reduce pressure drop in the flow splitter to one inch of water at 600 liters/min flow and to extend the range of linear flow measurement to 1000 liters/min are discussed.

  5. Delivery of tidal volume from four anaesthesia ventilators during volume-controlled ventilation: a bench study.

    PubMed

    Wallon, G; Bonnet, A; Guérin, C

    2013-06-01

    Tidal volume (V(T)) must be accurately delivered by anaesthesia ventilators in the volume-controlled ventilation mode in order for lung protective ventilation to be effective. However, the impact of fresh gas flow (FGF) and lung mechanics on delivery of V(T) by the newest anaesthesia ventilators has not been reported. We measured delivered V(T) (V(TI)) from four anaesthesia ventilators (Aisys™, Flow-i™, Primus™, and Zeus™) on a pneumatic test lung set with three combinations of lung compliance (C, ml cm H2O(-1)) and resistance (R, cm H2O litre(-1) s(-2)): C60R5, C30R5, C60R20. For each CR, three FGF rates (0.5, 3, 10 litre min(-1)) were investigated at three set V(T)s (300, 500, 800 ml) and two values of PEEP (0 and 10 cm H2O). The volume error = [(V(TI) - V(Tset))/V(Tset)] ×100 was computed in body temperature and pressure-saturated conditions and compared using analysis of variance. For each CR and each set V(T), the absolute value of the volume error significantly declined from Aisys™ to Flow-i™, Zeus™, and Primus™. For C60R5, these values were 12.5% for Aisys™, 5% for Flow-i™ and Zeus™, and 0% for Primus™. With an increase in FGF, absolute values of the volume error increased only for Aisys™ and Zeus™. However, in C30R5, the volume error was minimal at mid-FGF for Aisys™. The results were similar at PEEP 10 cm H2O. Under experimental conditions, the volume error differed significantly between the four new anaesthesia ventilators tested and was influenced by FGF, although this effect may not be clinically relevant.

  6. Spirometry and volumetric capnography in lung function assessment of obese and normal-weight individuals without asthma.

    PubMed

    Ferreira, Mariana S; Mendes, Roberto T; Marson, Fernando A L; Zambon, Mariana P; Antonio, Maria A R G M; Paschoal, Ilma A; Toro, Adyléia A D C; Severino, Silvana D; Ribeiro, Maria A G O; Ribeiro, José D

    To analyze and compare lung function of obese and healthy, normal-weight children and adolescents, without asthma, through spirometry and volumetric capnography. Cross-sectional study including 77 subjects (38 obese) aged 5-17 years. All subjects underwent spirometry and volumetric capnography. The evaluations were repeated in obese subjects after the use of a bronchodilator. At the spirometry assessment, obese individuals, when compared with the control group, showed lower values of forced expiratory volume in the first second by forced vital capacity (FEV 1 /FVC) and expiratory flows at 75% and between 25 and 75% of the FVC (p<0.05). Volumetric capnography showed that obese individuals had a higher volume of produced carbon dioxide and alveolar tidal volume (p<0.05). Additionally, the associations between dead space volume and tidal volume, as well as phase-3 slope normalized by tidal volume, were lower in healthy subjects (p<0.05). These data suggest that obesity does not alter ventilation homogeneity, but flow homogeneity. After subdividing the groups by age, a greater difference in lung function was observed in obese and healthy individuals aged >11 years (p<0.05). Even without the diagnosis of asthma by clinical criteria and without response to bronchodilator use, obese individuals showed lower FEV 1 /FVC values and forced expiratory flow, indicating the presence of an obstructive process. Volumetric capnography showed that obese individuals had higher alveolar tidal volume, with no alterations in ventilation homogeneity, suggesting flow alterations, without affecting lung volumes. Copyright © 2017 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  7. Numerical solution of the Saint-Venant equations by an efficient hybrid finite-volume/finite-difference method

    NASA Astrophysics Data System (ADS)

    Lai, Wencong; Khan, Abdul A.

    2018-04-01

    A computationally efficient hybrid finite-volume/finite-difference method is proposed for the numerical solution of Saint-Venant equations in one-dimensional open channel flows. The method adopts a mass-conservative finite volume discretization for the continuity equation and a semi-implicit finite difference discretization for the dynamic-wave momentum equation. The spatial discretization of the convective flux term in the momentum equation employs an upwind scheme and the water-surface gradient term is discretized using three different schemes. The performance of the numerical method is investigated in terms of efficiency and accuracy using various examples, including steady flow over a bump, dam-break flow over wet and dry downstream channels, wetting and drying in a parabolic bowl, and dam-break floods in laboratory physical models. Numerical solutions from the hybrid method are compared with solutions from a finite volume method along with analytic solutions or experimental measurements. Comparisons demonstrates that the hybrid method is efficient, accurate, and robust in modeling various flow scenarios, including subcritical, supercritical, and transcritical flows. In this method, the QUICK scheme for the surface slope discretization is more accurate and less diffusive than the center difference and the weighted average schemes.

  8. Table and charts of equilibrium normal-shock properties for hydrogen-helium mixtures with velocities to 70 km/sec. Volume 1: 0.95 H2-0.05 He (by volume)

    NASA Technical Reports Server (NTRS)

    Miller, C. G., III; Wilder, S. E.

    1976-01-01

    Equilibrium thermodynamic and flow properties are presented in tabulated and graphical form for moving, standing, and reflected normal shock waves into hydrogen-helium mixtures representative of postulated outer planet atmospheres. These results are presented in four volumes and the volmetric compositions of the mixtures are 0.95H2-0.05He in Volume 1, 0.90H2-0.10He in Volume 2, 0.85H2-0.15He in Volume 3, and 0.75H2-0.25He in Volume 4. Properties include pressure, temperature, density, enthalpy, speed of sound, entropy, molecular-weight ratio, isentropic exponent, velocity, and species mole fractions. Incident (moving) shock velocities are varied from 4 to 70 km/sec for a range of initial pressure of 5 N/sq m to 100 kN/sq m. Results are applicable to shock-tube flows and for determining flow conditions behind the normal portion of the bow shock about a blunt body at high velocities in postulated outer planet atmospheres. The document is a revised version of the original edition of NASA SP-3085 published in 1974.

  9. Control volume based hydrocephalus research

    NASA Astrophysics Data System (ADS)

    Cohen, Benjamin; Voorhees, Abram; Wei, Timothy

    2008-11-01

    Hydrocephalus is a disease involving excess amounts of cerebral spinal fluid (CSF) in the brain. Recent research has shown correlations to pulsatility of blood flow through the brain. However, the problem to date has presented as too complex for much more than statistical analysis and understanding. This talk will highlight progress on developing a fundamental control volume approach to studying hydrocephalus. The specific goals are to select physiologically control volume(s), develop conservation equations along with the experimental capabilities to accurately quantify terms in those equations. To this end, an in vitro phantom is used as a simplified model of the human brain. The phantom's design consists of a rigid container filled with a compressible gel. The gel has a hollow spherical cavity representing a ventricle and a cylindrical passage representing the aquaducts. A computer controlled piston pump supplies pulsatile volume fluctuations into and out of the flow phantom. MRI is used to measure fluid velocity, and volume change as functions of time. Independent pressure measurements and flow rate measurements are used to calibrate the MRI data. These data are used as a framework for future work with live patients.

  10. Influence of Dai-kenchu-to (DKT) on human portal blood flow.

    PubMed

    Ogasawara, Takashi; Morine, Yuji; Ikemoto, Tetsuya; Imura, Satoru; Fujii, Masahiko; Soejima, Yuji; Shimada, Mitsuo

    2008-01-01

    Dai-kenchu-to (DKT) is known as an herbal medicine used for postoperative ileus. However, no report exists about the effect of DKT on portal blood flow. The aim of this study is to clarify the influence of DKT on portal blood flow. To healthy volunteers (Healthy; n = 6), cirrhotic patients (Cirrhosis; n = 7) and liver-transplant patients (LTx; n = 3), DKT (2.5g) with 100mL of warm water was orally administrated in the DKT group, and only warm water was administrated in the control group. The portal blood flow rate (M-VEL: cm/sec.) and portal blood flow (Flow volume: mL/min.) was measured each time after administration using an ultrasonic Doppler method. Furthermore, the arterial blood pressure and heart rate was measured at the same time points. In the DKT group, a significant increase of M-VEL (120%) and flow volume (150%) 30 minutes after administration was observed in both Healthy and Cirrhosis in comparison with the control group. In LTx, there was also a significant increase of flow volume (128%) 30 minutes after administration. However, there was no change in average blood pressure and heart rate in all groups. DKT increases portal blood flow in early phase after oral administration without any significant changes in the blood pressure and heart rate.

  11. Emergency assessment of post-fire debris-flow hazards for the 2013 Springs Fire, Ventura County, California

    USGS Publications Warehouse

    Staley, Dennis M.

    2014-01-01

    Wildfire can significantly alter the hydrologic response of a watershed to the extent that even modest rainstorms can produce dangerous flash floods and debris flows. In this report, empirical models are used to predict the probability and magnitude of debris-flow occurrence in response to a 10-year rainstorm for the 2013 Springs fire in Ventura County, California. Overall, the models predict a relatively high probability (60–80 percent) of debris flow for 9 of the 99 drainage basins in the burn area in response to a 10-year recurrence interval design storm. Predictions of debris-flow volume suggest that debris flows may entrain a significant volume of material, with 28 of the 99 basins identified as having potential debris-flow volumes greater than 10,000 cubic meters. These results of the relative combined hazard analysis suggest there is a moderate likelihood of significant debris-flow hazard within and downstream of the burn area for nearby populations, infrastructure, wildlife, and water resources. Given these findings, we recommend that residents, emergency managers, and public works departments pay close attention to weather forecasts and National Weather Service-issued Debris Flow and Flash Flood Outlooks, Watches, and Warnings, and that residents adhere to any evacuation orders.

  12. Length and time for development of laminar flow in tubes following a step increase of volume flux

    NASA Astrophysics Data System (ADS)

    Chaudhury, Rafeed A.; Herrmann, Marcus; Frakes, David H.; Adrian, Ronald J.

    2015-01-01

    Laminar flows starting up from rest in round tubes are relevant to numerous industrial and biomedical applications. The two most common types are flows driven by an abruptly imposed constant pressure gradient or by an abruptly imposed constant volume flux. Analytical solutions are available for transient, fully developed flows, wherein streamwise development over the entrance length is absent (Szymanski in J de Mathématiques Pures et Appliquées 11:67-107, 1932; Andersson and Tiseth in Chem Eng Commun 112(1):121-133, 1992, respectively). They represent the transient responses of flows in tubes that are very long compared with the entrance length, a condition that is seldom satisfied in biomedical tube networks. This study establishes the entrance (development) length and development time of starting laminar flow in a round tube of finite length driven by a piston pump that produces a step change from zero flow to a constant volume flux for Reynolds numbers between 500 and 3,000. The flows are examined experimentally, using stereographic particle image velocimetry and computationally using computational fluid dynamics, and are then compared with the known analytical solutions for fully developed flow conditions in infinitely long tubes. Results show that step function volume flux start-up flows reach steady state and fully developed flow five times more quickly than those driven by a step function pressure gradient, a 500 % change when compared with existing estimates. Based on these results, we present new, simple guidelines for achieving experimental flows that are fully developed in space and time in realistic (finite) tube geometries. To a first approximation, the time to achieve steady spatially developing flow is nearly equal to the time needed to achieve steady, fully developed flow. Conversely, the entrance length needed to achieve fully developed transient flow is approximately equal to the length needed to achieve fully developed steady flow. Beyond this level of description, the numerical results reveal interaction between the effects of space and time development and nonlinear Reynolds number effects.

  13. Bathyphotometer bioluminescence potential measurements: A framework for characterizing flow agitators and predicting flow-stimulated bioluminescence intensity

    NASA Astrophysics Data System (ADS)

    Latz, Michael I.; Rohr, Jim

    2013-07-01

    Bathyphotometer measurements of bioluminescence are used as a proxy for the abundance of luminescent organisms for studying population dynamics; the interaction of luminescent organisms with physical, chemical, and biological oceanographic processes; and spatial complexity especially in coastal areas. However, the usefulness of bioluminescence measurements has been limited by the inability to compare results from different bathyphotometer designs, or even the same bathyphotometer operating at different volume flow rates. The primary objective of this study was to compare measurements of stimulated bioluminescence of four species of cultured dinoflagellates, the most common source of bioluminescence in coastal waters, using two different bathyphotometer flow agitators as a function of bathyphotometer volume flow rate and dinoflagellate concentration. For both the NOSC and BIOLITE flow agitators and each species of dinoflagellate tested, there was a critical volume flow rate, above which average bioluminescence intensity, designated as bathyphotometer bioluminescence potential (BBP), remained relatively constant and scaled directly with dinoflagellate cell concentration. At supra-critical volume flow rates, the ratio of BIOLITE to NOSC BBP was nearly constant for the same species studied, but varied between species. The spatial pattern and residence time of flash trajectories within the NOSC flow agitator indicated the presence of dominant secondary recirculating flows, where most of the bioluminescence was detected. A secondary objective (appearing in the Appendix) was to study the feasibility of using NOSC BBP to scale flow-stimulated bioluminescence intensity across similar flow fields, where the contributing composition of luminescent species remained the same. Fully developed turbulent pipe flow was chosen because it is hydrodynamically well characterized. Average bioluminescence intensity in a 2.54-cm i.d. pipe was highly correlated with wall shear stress and BBP. This correlation, when further scaled by pipe diameter, effectively predicted bioluminescence intensity in fully developed turbulent flow in a 0.83-cm i.d. pipe. Determining similar correlations between other bathyphotometer flow agitators and flow fields will allow bioluminescence potential measurements to become a more powerful tool for the oceanographic community.

  14. Clinical Investigation Program. Annual Progress Report. Volume 1

    DTIC Science & Technology

    1994-01-20

    Suport Labs Resch Chemist 13 0644 GS Salata, KF Allergy Microbiologist 12 0403 CS Billups, L Flow Cytom Microbiologist 12 0403 GS Dobek, AS Inf Disease 5...continued to increase laboratory research support to principal investigators throughout the medical center. The DCI Flow Cytometry Laboratory provided...Kalman PhD. Mitogen-Inducible T Suppressor Cell 12 Assay by Flow Cytometry (12/89) * Reference is to page number(s) in Volume II. 30 PROTOCOL NUMBER

  15. Real-time three-dimensional color doppler evaluation of the flow convergence zone for quantification of mitral regurgitation: Validation experimental animal study and initial clinical experience

    NASA Technical Reports Server (NTRS)

    Sitges, Marta; Jones, Michael; Shiota, Takahiro; Qin, Jian Xin; Tsujino, Hiroyuki; Bauer, Fabrice; Kim, Yong Jin; Agler, Deborah A.; Cardon, Lisa A.; Zetts, Arthur D.; hide

    2003-01-01

    BACKGROUND: Pitfalls of the flow convergence (FC) method, including 2-dimensional imaging of the 3-dimensional (3D) geometry of the FC surface, can lead to erroneous quantification of mitral regurgitation (MR). This limitation may be mitigated by the use of real-time 3D color Doppler echocardiography (CE). Our objective was to validate a real-time 3D navigation method for MR quantification. METHODS: In 12 sheep with surgically induced chronic MR, 37 different hemodynamic conditions were studied with real-time 3DCE. Using real-time 3D navigation, the radius of the largest hemispherical FC zone was located and measured. MR volume was quantified according to the FC method after observing the shape of FC in 3D space. Aortic and mitral electromagnetic flow probes and meters were balanced against each other to determine reference MR volume. As an initial clinical application study, 22 patients with chronic MR were also studied with this real-time 3DCE-FC method. Left ventricular (LV) outflow tract automated cardiac flow measurement (Toshiba Corp, Tokyo, Japan) and real-time 3D LV stroke volume were used to quantify the reference MR volume (MR volume = 3DLV stroke volume - automated cardiac flow measurement). RESULTS: In the sheep model, a good correlation and agreement was seen between MR volume by real-time 3DCE and electromagnetic (y = 0.77x + 1.48, r = 0.87, P <.001, delta = -0.91 +/- 2.65 mL). In patients, real-time 3DCE-derived MR volume also showed a good correlation and agreement with the reference method (y = 0.89x - 0.38, r = 0.93, P <.001, delta = -4.8 +/- 7.6 mL). CONCLUSIONS: real-time 3DCE can capture the entire FC image, permitting geometrical recognition of the FC zone geometry and reliable MR quantification.

  16. C-arm flat detector computed tomography parenchymal blood volume imaging: the nature of parenchymal blood volume parameter and the feasibility of parenchymal blood volume imaging in aneurysmal subarachnoid haemorrhage patients.

    PubMed

    Kamran, Mudassar; Byrne, James V

    2015-09-01

    C-arm flat detector computed tomography (FDCT) parenchymal blood volume (PBV) measurements allow assessment of cerebral haemodynamics in the neurointerventional suite. This paper explores the feasibility of C-arm computed tomography (CT) PBV imaging and the relationship between the C-arm CT PBV and the MR-PWI-derived cerebral blood volume (CBV) and cerebral blood flow (CBF) parameters in aneurysmal subarachnoid haemorrhage (SAH) patients developing delayed cerebral ischemia (DCI). Twenty-six patients with DCI following aneurysmal SAH underwent a research C-arm CT PBV scan using a biplane angiography system and contemporaneous MR-PWI scan as part of a prospective study. Quantitative whole-brain atlas-based volume-of-interest analysis in conjunction with Pearson correlation and Bland-Altman tests was performed to explore the agreement between C-arm CT PBV and MR-derived CBV and CBF measurements. All patients received medical management, while eight patients (31%) underwent selective intra-arterial chemical angioplasty. Colour-coded C-arm CT PBV maps were 91% sensitive and 100% specific in detecting the perfusion abnormalities. C-arm CT rPBV demonstrated good agreement and strong correlation with both MR-rCBV and MR-rCBF measurements; the agreement and correlation were stronger for MR-rCBF relative to MR-rCBV and improved for C-arm CT PBV versus the geometric mean of MR-rCBV and MR-rCBF. Analysis of weighted means showed that the C-arm CT PBV has a preferential blood flow weighting (≈ 60% blood flow and ≈ 40% blood volume weighting). C-arm CT PBV imaging is feasible in DCI following aneurysmal SAH. PBV is a composite perfusion parameter incorporating both blood flow and blood volume weightings. That PBV has preferential (≈ 60%) blood flow weighting is an important finding, which is of clinical significance when interpreting the C-arm CT PBV maps, particularly in the setting of acute brain ischemia.

  17. IMPROVED BIOSAND FILTERS BY ENHANCED MONITORING AND DATA COLLECTION METHODS

    EPA Science Inventory

    The result of this project will be the development of a sensor that will automatically and accurately record BSF use, flow rate, and volume of water poured in. The quantitative volume and flow rate data output will be used to compare actual BSF frequency and usage patterns ...

  18. Spinning fluids reactor

    DOEpatents

    Miller, Jan D; Hupka, Jan; Aranowski, Robert

    2012-11-20

    A spinning fluids reactor, includes a reactor body (24) having a circular cross-section and a fluid contactor screen (26) within the reactor body (24). The fluid contactor screen (26) having a plurality of apertures and a circular cross-section concentric with the reactor body (24) for a length thus forming an inner volume (28) bound by the fluid contactor screen (26) and an outer volume (30) bound by the reactor body (24) and the fluid contactor screen (26). A primary inlet (20) can be operatively connected to the reactor body (24) and can be configured to produce flow-through first spinning flow of a first fluid within the inner volume (28). A secondary inlet (22) can similarly be operatively connected to the reactor body (24) and can be configured to produce a second flow of a second fluid within the outer volume (30) which is optionally spinning.

  19. Comparison of 4D flow and 2D velocity-encoded phase contrast MRI sequences for the evaluation of aortic hemodynamics

    PubMed Central

    Bollache, Emilie; van Ooij, Pim; Powell, Alex; Carr, James; Markl, Michael; Barker, Alex J.

    2016-01-01

    The purpose of this study was to compare aortic flow and velocity quantification using 4D flow MRI and 2D CINE phase-contrast (PC)-MRI with either one-directional (2D-1dir) or three-directional (2D-3dir) velocity encoding. 15 healthy volunteers (51 ± 19 years) underwent MRI including (1) breath-holding 2D-1dir and (2) free breathing 2D-3dir PC-MRI in planes orthogonal to the ascending (AA) and descending (DA) aorta, as well as (3) free breathing 4D flow MRI with full thoracic aorta coverage. Flow quantification included the co-registration of the 2D PC acquisition planes with 4D flow MRI data, AA and DA segmentation, and calculation of AA and DA peak systolic velocity, peak flow and net flow volume for all sequences. Additionally, the 2D-3dir velocity taking into account the through-plane component only was used to obtain results analogous to a free breathing 2D-1dir acquisition. Good agreement was found between 4D flow and 2D-3dir peak velocity (differences = −3 to 6 %), peak flow (−7 %) and net volume (−14 to −9 %). In contrast, breath-holding 2D-1dir measurements exhibited indices significantly lower than free breathing 2D-3dir and 2D-1dir (differences = −35 to −7 %, p < 0.05). Finally, high correlations (r ≥ 0.97) were obtained for indices estimated with or without eddy current correction, with the lowest correlation observed for net volume. 4D flow and 2D-3dir aortic hemodynamic indices were in concordance. However, differences between respiration state and 2D-1dir and 2D-3dir measurements indicate that reference values should be established according to the PC-MRI sequence, especially for the widely used net flow (e.g. stroke volume in the AA). PMID:27435230

  20. Cough-Associated Changes in CSF Flow in Chiari I Malformation Evaluated by Real-Time MRI.

    PubMed

    Bhadelia, R A; Patz, S; Heilman, C; Khatami, D; Kasper, E; Zhao, Y; Madan, N

    2016-05-01

    Invasive pressure studies have suggested that CSF flow across the foramen magnum may transiently decrease after coughing in patients with symptomatic Chiari I malformation. The purpose of this exploratory study was to demonstrate this phenomenon noninvasively by assessing CSF flow response to coughing in symptomatic patients with Chiari I malformation by using MR pencil beam imaging and to compare the response with that in healthy participants. Eight symptomatic patients with Chiari I malformation and 6 healthy participants were studied by using MR pencil beam imaging with a temporal resolution of ∼50 ms. Patients and healthy participants were scanned for 90 seconds (without cardiac gating) to continuously record cardiac cycle-related CSF flow waveforms in real-time during resting, coughing, and postcoughing periods. CSF flow waveform amplitude, CSF stroke volume, and CSF flow rate (CSF Flow Rate = CSF Stroke Volume × Heart Rate) in the resting and immediate postcoughing periods were determined and compared between patients and healthy participants. There was no significant difference in CSF flow waveform amplitude, CSF stroke volume, and the CSF flow rate between patients with Chiari I malformation and healthy participants during rest. However, immediately after coughing, a significant decrease in CSF flow waveform amplitude (P < .001), CSF stroke volume (P = .001), and CSF flow rate (P = .001) was observed in patients with Chiari I malformation but not in the healthy participants. Real-time MR imaging noninvasively showed a transient decrease in CSF flow across the foramen magnum after coughing in symptomatic patients with Chiari I malformation, a phenomenon not seen in healthy participants. Our results provide preliminary evidence that the physiology-based imaging method used here has the potential to be an objective clinical test to differentiate symptomatic from asymptomatic patients with Chiari I malformation. © 2016 by American Journal of Neuroradiology.

  1. Medication and volume delivery by gravity-driven micro-drip intravenous infusion: potential variations during "wide-open" flow.

    PubMed

    Pierce, Eric T; Kumar, Vikram; Zheng, Hui; Peterfreund, Robert A

    2013-03-01

    Gravity-driven micro-drip infusion sets allow control of medication dose delivery by adjusting drops per minute. When the roller clamp is fully open, flow in the drip chamber can be a continuous fluid column rather than discrete, countable, drops. We hypothesized that during this "wide-open" state, drug delivery becomes dependent on factors extrinsic to the micro-drip set and is therefore difficult to predict. We conducted laboratory experiments to characterize volume delivery under various clinically relevant conditions of wide-open flow in an in vitro laboratory model. A micro-drip infusion set, plugged into a bag of normal saline, was connected to a high-flow stopcock at the distal end. Vertically oriented IV catheters (gauges 14-22) were connected to the stopcock. The fluid meniscus height in the bag was fixed (60-120 cm) above the outflow point. The roller clamp on the infusion set was in fully open position for all experiments resulting in a continuous column of fluid in the drip chamber. Fluid volume delivered in 1 minute was measured 4 times with each condition. To model resistive effects of carrier flow, volumetric infusion pumps were used to deliver various flow rates of normal saline through a carrier IV set into which a micro-drip infusion was "piggybacked." We also compared delivery by micro-drip infusion sets from 3 manufacturers. The volume of fluid delivered by gravity-driven infusion under wide-open conditions (continuous fluid column in drip chamber) varied 2.9-fold (95% confidence interval, 2.84-2.96) depending on catheter size and fluid column height. Total model resistance of the micro-drip with stopcock and catheter varied with flow rate. Volume delivered by the piggybacked micro-drip decreased up to 29.7% ± 0.8% (mean ± SE) as the carrier flow increased from 0 to 1998 mL/min. Delivery characteristics of the micro-drip infusion sets from 3 different manufacturers were similar. Laboratory simulation of clinical situations with gravity-driven micro-drip infusion sets under wide-open flow conditions revealed that infusion rate (drug and/or volume delivery) can vary widely depending on extrinsic factors including catheter size, fluid column height, and carrier flow. The variable resistance implies nonlaminar flow in the micro-drip model that cannot be easily predicted mathematically. These findings support the use of mechanical pumps instead of gravity-driven micro-drips to enhance the precision and safety of IV infusions, especially for vasoactive drugs.

  2. Mobility statistics and automated hazard mapping for debris flows and rock avalanches

    USGS Publications Warehouse

    Griswold, Julia P.; Iverson, Richard M.

    2008-01-01

    Power-law equations that are physically motivated and statistically tested and calibrated provide a basis for forecasting areas likely to be inundated by debris flows, rock avalanches, and lahars with diverse volumes. The equations A=α1V2/3 and B=α2V2/3 are based on the postulate that the maximum valley cross-sectional area (A) and total valley planimetric area (B) likely to be inundated by a flow depend only on its volume (V) and the topography of the flow path. Testing of these equations involves determining whether or not they fit data for documented flows satisfactorily, and calibration entails determining best-fit values of the coefficients α1 and α2 for debris flows, rock avalanches, and lahars. This report describes statistical testing and calibration of the equations by using field data compiled from many sources, and it describes application of the equations to delineation of debris-flow hazard zones. Statistical results show that for each type of flow (debris flows, rock avalanches, and lahars), the dependence of A and B on V is described well by power laws with exponents equal to 2/3. This value of the exponent produces fits that are effectively indistinguishable from the best fits obtained by using adjustable power-law exponents. Statistically calibrated values of the coefficients α1 and α2 provide scale-invariant indices of the relative mobilities of rock avalanches (α1 = 0.2, α2 = 20), nonvolcanic debris flows (α1 = 0.1, α2 = 20), and lahars (α1 = 0.05, α2 = 200). These values show, for example, that a lahar of specified volume can be expected to inundate a planimetric area ten times larger than that inundated by a rock avalanche or nonvolcanic debris flow of the same volume. The utility of the calibrated debris-flow inundation equations A=0.1V2/3 and B=20V2/3 is demonstrated by using them within the GIS program LAHARZ to delineate nested hazard zones for future debris flows in an area bordering the Umpqua River in the south-central Oregon Coast Range. This application requires use of high-resolution topographic data derived form LIDAR surveys, knowledge of local geology to specify a suitable range of prospective debris-flow volumes, and development and use of a new algorithm for identification of prospective debris-flow source areas in finely dissected terrain.

  3. Combined Effects of Flow Diverting Strategies and Parent Artery Curvature on Aneurysmal Hemodynamics: A CFD Study

    PubMed Central

    Yu, Ying; Lv, Nan; Wang, Shengzhang; Karmonik, Christof; Liu, Jian-Min; Huang, Qinghai

    2015-01-01

    Purpose Flow diverters (FD) are increasingly being considered for treating large or giant wide-neck aneurysms. Clinical outcome is highly variable and depends on the type of aneurysm, the flow diverting device and treatment strategies. The objective of this study was to analyze the effect of different flow diverting strategies together with parent artery curvature variations on altering intra-aneurysmal hemodynamics. Methods Four ideal intracranial aneurysm models with different parent artery curvature were constructed. Computational fluid dynamics (CFD) simulations of the hemodynamics before and after applying five types of flow diverting strategies (single FD, single FD with 5% and 10% packing density of coils, two FDs with 25% and 50% overlapping rate) were performed. Changes in pressure, wall shear stress (WSS), relative residence time (RRT), inflow velocity and inflow volume rate were calculated and compared. Results Each flow diverting strategy resulted in enhancement of RRT and reduction of normalized mean WSS, inflow volume rate and inflow velocity in various levels. Among them, 50% overlapped FD induced most effective hemodynamic changes in RRT and inflow volume rate. The mean pressure only slightly decreased after treatment. Regardless of the kind of implantation of FD, the mean pressure, inflow volume rate and inflow velocity increased and the RRT decreased as the curvature of the parent artery increased. Conclusions Of all flow diverting strategies, overlapping FDs induced most favorable hemodynamic changes. Hemodynamics alterations post treatment were substantially influenced by parent artery curvature. Our results indicate the need of an individualized flow diverting strategy that is tailored for a specific aneurysm. PMID:26398847

  4. Immersive volume rendering of blood vessels

    NASA Astrophysics Data System (ADS)

    Long, Gregory; Kim, Han Suk; Marsden, Alison; Bazilevs, Yuri; Schulze, Jürgen P.

    2012-03-01

    In this paper, we present a novel method of visualizing flow in blood vessels. Our approach reads unstructured tetrahedral data, resamples it, and uses slice based 3D texture volume rendering. Due to the sparse structure of blood vessels, we utilize an octree to efficiently store the resampled data by discarding empty regions of the volume. We use animation to convey time series data, wireframe surface to give structure, and utilize the StarCAVE, a 3D virtual reality environment, to add a fully immersive element to the visualization. Our tool has great value in interdisciplinary work, helping scientists collaborate with clinicians, by improving the understanding of blood flow simulations. Full immersion in the flow field allows for a more intuitive understanding of the flow phenomena, and can be a great help to medical experts for treatment planning.

  5. Probability and volume of potential postwildfire debris flows in the 2010 Fourmile burn area, Boulder County, Colorado

    USGS Publications Warehouse

    Ruddy, Barbara C.; Stevens, Michael R.; Verdin, Kristine

    2010-01-01

    This report presents a preliminary emergency assessment of the debris-flow hazards from drainage basins burned by the Fourmile Creek fire in Boulder County, Colorado, in 2010. Empirical models derived from statistical evaluation of data collected from recently burned basins throughout the intermountain western United States were used to estimate the probability of debris-flow occurrence and volumes of debris flows for selected drainage basins. Data for the models include burn severity, rainfall total and intensity for a 25-year-recurrence, 1-hour-duration rainstorm, and topographic and soil property characteristics. Several of the selected drainage basins in Fourmile Creek and Gold Run were identified as having probabilities of debris-flow occurrence greater than 60 percent, and many more with probabilities greater than 45 percent, in response to the 25-year recurrence, 1-hour rainfall. None of the Fourmile Canyon Creek drainage basins selected had probabilities greater than 45 percent. Throughout the Gold Run area and the Fourmile Creek area upstream from Gold Run, the higher probabilities tend to be in the basins with southerly aspects (southeast, south, and southwest slopes). Many basins along the perimeter of the fire area were identified as having low probability of occurrence of debris flow. Volume of debris flows predicted from drainage basins with probabilities of occurrence greater than 60 percent ranged from 1,200 to 9,400 m3. The predicted moderately high probabilities and some of the larger volumes responses predicted for the modeled storm indicate a potential for substantial debris-flow effects to buildings, roads, bridges, culverts, and reservoirs located both within these drainages and immediately downstream from the burned area. However, even small debris flows that affect structures at the basin outlets could cause considerable damage.

  6. Emergency Assessment of Postfire Debris-Flow Hazards for the 2009 Station Fire, San Gabriel Mountains, Southern California

    USGS Publications Warehouse

    Cannon, Susan H.; Gartner, Joseph E.; Rupert, Michael G.; Michael, John A.; Staley, Dennis M.; Worstell, Bruce B.

    2009-01-01

    This report presents an emergency assessment of potential debris-flow hazards from basins burned by the 2009 Station fire in Los Angeles County, southern California. Statistical-empirical models developed for postfire debris flows are used to estimate the probability and volume of debris-flow production from 678 drainage basins within the burned area and to generate maps of areas that may be inundated along the San Gabriel mountain front by the estimated volume of material. Debris-flow probabilities and volumes are estimated as combined functions of different measures of basin burned extent, gradient, and material properties in response to both a 3-hour-duration, 1-year-recurrence thunderstorm and to a 12-hour-duration, 2-year recurrence storm. Debris-flow inundation areas are mapped for scenarios where all sediment-retention basins are empty and where the basins are all completely full. This assessment provides critical information for issuing warnings, locating and designing mitigation measures, and planning evacuation timing and routes within the first two winters following the fire. Tributary basins that drain into Pacoima Canyon, Big Tujunga Canyon, Arroyo Seco, West Fork of the San Gabriel River, and Devils Canyon were identified as having probabilities of debris-flow occurrence greater than 80 percent, the potential to produce debris flows with volumes greater than 100,000 m3, and the highest Combined Relative Debris-Flow Hazard Ranking in response to both storms. The predicted high probability and large magnitude of the response to such short-recurrence storms indicates the potential for significant debris-flow impacts to any buildings, roads, bridges, culverts, and reservoirs located both within these drainages and downstream from the burned area. These areas will require appropriate debris-flow mitigation and warning efforts. Probabilities of debris-flow occurrence greater than 80 percent, debris-flow volumes between 10,000 and 100,000 m3, and high Combined Relative Debris-Flow Hazard Rankings were estimated in response to both short recurrence-interval (1- and 2-year) storms for all but the smallest basins along the San Gabriel mountain front between Big Tujunga Canyon and Arroyo Seco. The combination of high probabilities and large magnitudes determined for these basins indicates significant debris-flow hazards for neighborhoods along the mountain front. When the capacity of sediment-retention basins is exceeded, debris flows may be deposited in neighborhoods and streets and impact infrastructure between the mountain front and Foothill Boulevard. In addition, debris flows may be deposited in neighborhoods immediately below unprotected basins. Hazards to neighborhoods and structures at risk from these events will require appropriate debris-flow mitigation and warning efforts.

  7. Implementation of Finite Volume based Navier Stokes Algorithm Within General Purpose Flow Network Code

    NASA Technical Reports Server (NTRS)

    Schallhorn, Paul; Majumdar, Alok

    2012-01-01

    This paper describes a finite volume based numerical algorithm that allows multi-dimensional computation of fluid flow within a system level network flow analysis. There are several thermo-fluid engineering problems where higher fidelity solutions are needed that are not within the capacity of system level codes. The proposed algorithm will allow NASA's Generalized Fluid System Simulation Program (GFSSP) to perform multi-dimensional flow calculation within the framework of GFSSP s typical system level flow network consisting of fluid nodes and branches. The paper presents several classical two-dimensional fluid dynamics problems that have been solved by GFSSP's multi-dimensional flow solver. The numerical solutions are compared with the analytical and benchmark solution of Poiseulle, Couette and flow in a driven cavity.

  8. Quantitative analysis of aortic regurgitation: real-time 3-dimensional and 2-dimensional color Doppler echocardiographic method--a clinical and a chronic animal study

    NASA Technical Reports Server (NTRS)

    Shiota, Takahiro; Jones, Michael; Tsujino, Hiroyuki; Qin, Jian Xin; Zetts, Arthur D.; Greenberg, Neil L.; Cardon, Lisa A.; Panza, Julio A.; Thomas, James D.

    2002-01-01

    BACKGROUND: For evaluating patients with aortic regurgitation (AR), regurgitant volumes, left ventricular (LV) stroke volumes (SV), and absolute LV volumes are valuable indices. AIM: The aim of this study was to validate the combination of real-time 3-dimensional echocardiography (3DE) and semiautomated digital color Doppler cardiac flow measurement (ACM) for quantifying absolute LV volumes, LVSV, and AR volumes using an animal model of chronic AR and to investigate its clinical applicability. METHODS: In 8 sheep, a total of 26 hemodynamic states were obtained pharmacologically 20 weeks after the aortic valve noncoronary (n = 4) or right coronary (n = 4) leaflet was incised to produce AR. Reference standard LVSV and AR volume were determined using the electromagnetic flow method (EM). Simultaneous epicardial real-time 3DE studies were performed to obtain LV end-diastolic volumes (LVEDV), end-systolic volumes (LVESV), and LVSV by subtracting LVESV from LVEDV. Simultaneous ACM was performed to obtain LVSV and transmitral flows; AR volume was calculated by subtracting transmitral flow volume from LVSV. In a total of 19 patients with AR, real-time 3DE and ACM were used to obtain LVSVs and these were compared with each other. RESULTS: A strong relationship was found between LVSV derived from EM and those from the real-time 3DE (r = 0.93, P <.001, mean difference (3D - EM) = -1.0 +/- 9.8 mL). A good relationship between LVSV and AR volumes derived from EM and those by ACM was found (r = 0.88, P <.001). A good relationship between LVSV derived from real-time 3DE and that from ACM was observed (r = 0.73, P <.01, mean difference = 2.5 +/- 7.9 mL). In patients, a good relationship between LVSV obtained by real-time 3DE and ACM was found (r = 0.90, P <.001, mean difference = 0.6 +/- 9.8 mL). CONCLUSION: The combination of ACM and real-time 3DE for quantifying LV volumes, LVSV, and AR volumes was validated by the chronic animal study and was shown to be clinically applicable.

  9. Laminar, turbulent, and inertial shear-thickening regimes in channel flow of neutrally buoyant particle suspensions.

    PubMed

    Lashgari, Iman; Picano, Francesco; Breugem, Wim-Paul; Brandt, Luca

    2014-12-19

    The aim of this Letter is to characterize the flow regimes of suspensions of finite-size rigid particles in a viscous fluid at finite inertia. We explore the system behavior as a function of the particle volume fraction and the Reynolds number (the ratio of flow and particle inertia to viscous forces). Unlike single-phase flows, where a clear distinction exists between the laminar and the turbulent states, three different regimes can be identified in the presence of a particulate phase, with smooth transitions between them. At low volume fractions, the flow becomes turbulent when increasing the Reynolds number, transitioning from the laminar regime dominated by viscous forces to the turbulent regime characterized by enhanced momentum transport by turbulent eddies. At larger volume fractions, we identify a new regime characterized by an even larger increase of the wall friction. The wall friction increases with the Reynolds number (inertial effects) while the turbulent transport is weakly affected, as in a state of intense inertial shear thickening. This state may prevent the transition to a fully turbulent regime at arbitrary high speed of the flow.

  10. Counterflow heat exchanger with core and plenums at both ends

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bejan, A.; Alalaimi, M.; Lorente, S.

    2016-04-22

    Here, this paper illustrates the morphing of flow architecture toward greater performance in a counterflow heat exchanger. The architecture consists of two plenums with a core of counterflow channels between them. Each stream enters one plenum and then flows in a channel that travels the core and crosses the second plenum. The volume of the heat exchanger is fixed while the volume fraction occupied by each plenum is variable. Performance is driven by two objectives, simultaneously: low flow resistance and low thermal resistance. The analytical and numerical results show that the overall flow resistance is the lowest when the coremore » is absent, and each plenum occupies half of the available volume and is oriented in counterflow with the other plenum. In this configuration, the thermal resistance also reaches its lowest value. These conclusions hold for fully developed laminar flow and turbulent flow through the core. The curve for effectiveness vs number of heat transfer units (N tu) is steeper (when N tu < 1) than the classical curves for counterflow and crossflow.« less

  11. Shear-induced structural transitions in Newtonian non-Newtonian two-phase flow

    NASA Astrophysics Data System (ADS)

    Cristobal, G.; Rouch, J.; Colin, A.; Panizza, P.

    2000-09-01

    We show the existence under shear flow of steady states in a two-phase region of a brine-surfactant system in which lyotropic dilute lamellar (non-Newtonian) and sponge (Newtonian) phases are coexisting. At high shear rates and low sponge phase-volume fractions, we report on the existence of a dynamic transition corresponding to the formation of a colloidal crystal of multilamellar vesicles (or ``onions'') immersed in the sponge matrix. As the sponge phase-volume fraction increases, this transition exhibits a hysteresis loop leading to a structural bistability of the two-phase flow. Contrary to single phase lamellar systems where it is always 100%, the onion volume fraction can be monitored continuously from 0 to 100 %.

  12. Liquid chromatography/Fourier transform IR spectrometry interface flow cell

    DOEpatents

    Johnson, Charles C.; Taylor, Larry T.

    1986-01-01

    A zero dead volume (ZDV) microbore high performance liquid chromatography (.mu.HPLC)/Fourier transform infrared (FTIR) interface flow cell includes an IR transparent crystal having a small diameter bore therein through which a sample liquid is passed. The interface flow cell further includes a metal holder in combination with a pair of inner, compressible seals for directly coupling the thus configured spectrometric flow cell to the outlet of a .mu.HPLC column end fitting to minimize the transfer volume of the effluents exiting the .mu.HPLC column which exhibit excellent flow characteristics due to the essentially unencumbered, open-flow design. The IR beam passes transverse to the sample flow through the circular bore within the IR transparent crystal, which is preferably comprised of potassium bromide (KBr) or calcium fluoride (CaF.sub.2), so as to minimize interference patterns and vignetting encountered in conventional parallel-plate IR cells. The long IR beam pathlength and lensing effect of the circular cross-section of the sample volume in combination with the refractive index differences between the solvent and the transparent crystal serve to focus the IR beam in enhancing sample detection sensitivity by an order of magnitude.

  13. Liquid chromatography/Fourier transform IR spectrometry interface flow cell

    DOEpatents

    Johnson, C.C.; Taylor, L.T.

    1985-01-04

    A zero dead volume (ZDV) microbore high performance liquid chromatography (..mu.. HPLC)/Fourier transform infrared (FTIR) interface flow cell includes an IR transparent crystal having a small diameter bore therein through which a sample liquid is passed. The interface flow cell further includes a metal holder in combination with a pair of inner, compressible seals for directly coupling the thus configured spectrometric flow cell to the outlet of a ..mu.. HPLC column end fitting to minimize the transfer volume of the effluents exiting the ..mu.. HPLC column which exhibit excellent flow characteristics due to the essentially unencumbered, open-flow design. The IR beam passes transverse to the sample flow through the circular bore within the IR transparent crystal, which is preferably comprised of potassium bromide (KBr) or calcium fluoride (CaF/sub 2/), so as to minimize interference patterns and vignetting encountered in conventional parallel-plate IR cells. The long IR beam pathlength and lensing effect of the circular cross-section of the sample volume in combination with the refractive index differences between the solvent and the transparent crystal serve to focus the IR beam in enhancing sample detection sensitivity by an order of magnitude.

  14. Design and Construction of Aquaculture Facilities in Dredged Material Containment Areas

    DTIC Science & Technology

    1993-07-01

    detail. The following discussion of centrifugal and axial flow pumps is adapted from Wheaton (1977), Baker (1987), and Baker and Bankston (1988...at a right angle to the impeller shaft. Axial flow propeller pumps are also used, especially in high-volume low-lift situations. The propeller may look...horizontal centrifugal pump or the axial flow pump may be used. Both of these pumps provide large volumes of water under low head conditions. Many

  15. Slug sizing/slug volume prediction, state of the art review and simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burke, N.E.; Kashou, S.F.

    1995-12-01

    Slug flow is a flow pattern commonly encountered in offshore multiphase flowlines. It is characterized by an alternate flow of liquid slugs and gas pockets, resulting in an unsteady hydrodynamic behavior. All important design variables, such as slug length and slug frequency, liquid holdup, and pressure drop, vary with time and this makes the prediction of slug flow characteristics both difficult and challenging. This paper reviews the state of the art methods in slug catcher sizing and slug volume predictions. In addition, history matching of measured slug flow data is performed using the OLGA transient simulator. This paper reviews themore » design factors that impact slug catcher sizing during steady state, during transient, during pigging, and during operations under a process control system. The slug tracking option of the OLGA simulator is applied to predict the slug length and the slug volume during a field operation. This paper will also comment on the performance of common empirical slug prediction correlations.« less

  16. Slug-sizing/slug-volume prediction: State of the art review and simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burke, N.E.; Kashou, S.F.

    1996-08-01

    Slug flow is a flow pattern commonly encountered in offshore multiphase flowlines. It is characterized by an alternate flow of liquid slugs and gas pockets, resulting in an unsteady hydrodynamic behavior. All important design variables, such as slug length and slug frequency, liquid holdup, and pressure drop, vary with time and this makes the prediction of slug flow characteristics both difficult and challenging. This paper reviews the state of the art methods in slug-catcher sizing and slug-volume predictions. In addition, history matching of measured slug flow data is performed using the OLGA transient simulator. This paper reviews the design factorsmore » that impact slug-catcher sizing during steady state, during transient, during pigging, and during operations under a process-control system. The slug-tracking option of the simulator is applied to predict the slug length and the slug volume during a field operation. This paper will also comment on the performance of common empirical slug-prediction correlations.« less

  17. Volume-Of-Fluid Simulation for Predicting Two-Phase Cooling in a Microchannel

    NASA Astrophysics Data System (ADS)

    Gorle, Catherine; Parida, Pritish; Houshmand, Farzad; Asheghi, Mehdi; Goodson, Kenneth

    2014-11-01

    Two-phase flow in microfluidic geometries has applications of increasing interest for next generation electronic and optoelectronic systems, telecommunications devices, and vehicle electronics. While there has been progress on comprehensive simulation of two-phase flows in compact geometries, validation of the results in different flow regimes should be considered to determine the predictive capabilities. In the present study we use the volume-of-fluid method to model the flow through a single micro channel with cross section 100 × 100 μm and length 10 mm. The channel inlet mass flux and the heat flux at the lower wall result in a subcooled boiling regime in the first 2.5 mm of the channel and a saturated flow regime further downstream. A conservation equation for the vapor volume fraction, and a single set of momentum and energy equations with volume-averaged fluid properties are solved. A reduced-physics phase change model represents the evaporation of the liquid and the corresponding heat loss, and the surface tension is accounted for by a source term in the momentum equation. The phase change model used requires the definition of a time relaxation parameter, which can significantly affect the solution since it determines the rate of evaporation. The results are compared to experimental data available from literature, focusing on the capability of the reduced-physics phase change model to predict the correct flow pattern, temperature profile and pressure drop.

  18. Natural gas flow through critical nozzles

    NASA Technical Reports Server (NTRS)

    Johnson, R. C.

    1969-01-01

    Empirical method for calculating both the mass flow rate and upstream volume flow rate through critical flow nozzles is determined. Method requires knowledge of the composition of natural gas, and of the upstream pressure and temperature.

  19. Gated CT imaging using a free-breathing respiration signal from flow-volume spirometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    D'Souza, Warren D.; Kwok, Young; Deyoung, Chad

    2005-12-15

    Respiration-induced tumor motion is known to cause artifacts on free-breathing spiral CT images used in treatment planning. This leads to inaccurate delineation of target volumes on planning CT images. Flow-volume spirometry has been used previously for breath-holds during CT scans and radiation treatments using the active breathing control (ABC) system. We have developed a prototype by extending the flow-volume spirometer device to obtain gated CT scans using a PQ 5000 single-slice CT scanner. To test our prototype, we designed motion phantoms to compare image quality obtained with and without gated CT scan acquisition. Spiral and axial (nongated and gated) CTmore » scans were obtained of phantoms with motion periods of 3-5 s and amplitudes of 0.5-2 cm. Errors observed in the volume estimate of these structures were as much as 30% with moving phantoms during CT simulation. Application of motion-gated CT with active breathing control reduced these errors to within 5%. Motion-gated CT was then implemented in patients and the results are presented for two clinical cases: lung and abdomen. In each case, gated scans were acquired at end-inhalation, end-exhalation in addition to a conventional free-breathing (nongated) scan. The gated CT scans revealed reduced artifacts compared with the conventional free-breathing scan. Differences of up to 20% in the volume of the structures were observed between gated and free-breathing scans. A comparison of the overlap of structures between the gated and free-breathing scans revealed misalignment of the structures. These results demonstrate the ability of flow-volume spirometry to reduce errors in target volumes via gating during CT imaging.« less

  20. Vital capacities in acute and chronic airway obstruction: dependence on flow and volume histories.

    PubMed

    Brusasco, V; Pellegrino, R; Rodarte, J R

    1997-06-01

    The aim of this study was to investigate whether measurements of vital capacity (VC) are affected by the direction of the manoeuvre (inspiratory vs expiratory) and by the rate of expiratory flow. The study was performed on 25 individuals with chronic airway obstruction (CAO) and a forced expiratory volume in one second (FEV1) (expressed in standardized residuals (SR)) of -2.0+/-1.4 SD (CAO group), and 10 asthmatic subjects with methacholine (MCh)-induced bronchoconstriction (FEV1 -23+/-1.02 SR) (MCh group). VCs were measured during fast inspiration following both slow (FIVCse) and forced (FIVCfe) expiration from end-tidal inspiration to residual volume (RV), and during slow (EVC) or forced (FVC) expiration from total lung capacity (TLC). In the CAO group, FVC was the smallest volume (3.75+/-1.03 L) and significantly different from the other three estimates of VC; FIVCse (4.03+/-0.91 L) was the largest volume and significantly different from FVC and FIVCfe (3.83+/-0.98 L). In the MCh group, FVC (4.16+/-0.94 L) and EVC (4.19+/-0.89 L) were the largest volumes, although only the difference between FVC and FIVCfe (3.76+/-0.81 L) reached statistical significance. These data suggest that both flow and volume histories contribute to decreased vital capacities during bronchoconstriction. However, whereas increasing expiratory flow always tends to decrease vital capacity, the volume history of full inflation has different effects in chronic and acute bronchoconstriction, probably due to different effects on airway calibre. These results stress the importance of using standardized manoeuvres in order to obtain comparable values of vital capacity.

  1. Achieving high convection volumes in postdilution online hemodiafiltration: a prospective multicenter study

    PubMed Central

    Chapdelaine, Isabelle; Nubé, Menso J; Blankestijn, Peter J; Bots, Michiel L; Konings, Constantijn J A M; Kremer Hovinga, Ton K; Molenaar, Femke M; van der Weerd, Neelke C; Grooteman, Muriel P C

    2017-01-01

    Abstract Background. Available evidence suggests a reduced mortality risk for patients treated with high-volume postdilution hemodiafiltration (HDF) when compared with hemodialysis (HD) patients. As the magnitude of the convection volume depends on treatment-related factors rather than patient-related characteristics, we prospectively investigated whether a high convection volume (defined as ≥22 L/session) is feasible in the majority of patients (>75%). Methods. A multicenter study was performed in adult prevalent dialysis patients. Nonparticipating eligible patients formed the control group. Using a stepwise protocol, treatment time (up to 4 hours), blood flow rate (up to 400 mL/min) and filtration fraction (up to 33%) were optimized as much as possible. The convection volume was determined at the end of this optimization phase and at 4 and 8 weeks thereafter. Results. Baseline characteristics were comparable in participants (n = 86) and controls (n = 58). At the end of the optimization and 8 weeks thereafter, 71/86 (83%) and 66/83 (80%) of the patients achieved high-volume HDF (mean 25.5 ± 3.6 and 26.0 ± 3.4 L/session, respectively). While treatment time remained unaltered, mean blood flow rate increased by 27% and filtration fraction increased by 23%. Patients with <22 L/session had a higher percentage of central venous catheters (CVCs), a shorter treatment time and lower blood flow rate when compared with patients with ≥22 L/session. Conclusions. High-volume HDF is feasible in a clear majority of dialysis patients. Since none of the patients agreed to increase treatment time, these findings indicate that high-volume HDF is feasible just by increasing blood flow rate and filtration fraction. PMID:29225810

  2. Integrated Microfluidic Flow-Through Microbial Fuel Cells

    PubMed Central

    Jiang, Huawei; Ali, Md. Azahar; Xu, Zhen; Halverson, Larry J.; Dong, Liang

    2017-01-01

    This paper reports on a miniaturized microbial fuel cell with a microfluidic flow-through configuration: a porous anolyte chamber is formed by filling a microfluidic chamber with three-dimensional graphene foam as anode, allowing nutritional medium to flow through the chamber to intimately interact with the colonized microbes on the scaffolds of the anode. No nutritional media flow over the anode. This allows sustaining high levels of nutrient utilization, minimizing consumption of nutritional substrates, and reducing response time of electricity generation owing to fast mass transport through pressure-driven flow and rapid diffusion of nutrients within the anode. The device provides a volume power density of 745 μW/cm3 and a surface power density of 89.4 μW/cm2 using Shewanella oneidensis as a model biocatalyst without any optimization of bacterial culture. The medium consumption and the response time of the flow-through device are reduced by 16.4 times and 4.2 times, respectively, compared to the non-flow-through counterpart with its freeway space volume six times the volume of graphene foam anode. The graphene foam enabled microfluidic flow-through approach will allow efficient microbial conversion of carbon-containing bioconvertible substrates to electricity with smaller space, less medium consumption, and shorter start-up time. PMID:28120875

  3. Integrated Microfluidic Flow-Through Microbial Fuel Cells

    NASA Astrophysics Data System (ADS)

    Jiang, Huawei; Ali, Md. Azahar; Xu, Zhen; Halverson, Larry J.; Dong, Liang

    2017-01-01

    This paper reports on a miniaturized microbial fuel cell with a microfluidic flow-through configuration: a porous anolyte chamber is formed by filling a microfluidic chamber with three-dimensional graphene foam as anode, allowing nutritional medium to flow through the chamber to intimately interact with the colonized microbes on the scaffolds of the anode. No nutritional media flow over the anode. This allows sustaining high levels of nutrient utilization, minimizing consumption of nutritional substrates, and reducing response time of electricity generation owing to fast mass transport through pressure-driven flow and rapid diffusion of nutrients within the anode. The device provides a volume power density of 745 μW/cm3 and a surface power density of 89.4 μW/cm2 using Shewanella oneidensis as a model biocatalyst without any optimization of bacterial culture. The medium consumption and the response time of the flow-through device are reduced by 16.4 times and 4.2 times, respectively, compared to the non-flow-through counterpart with its freeway space volume six times the volume of graphene foam anode. The graphene foam enabled microfluidic flow-through approach will allow efficient microbial conversion of carbon-containing bioconvertible substrates to electricity with smaller space, less medium consumption, and shorter start-up time.

  4. A two-phase debris-flow model that includes coupled evolution of volume fractions, granular dilatancy, and pore-fluid pressure

    USGS Publications Warehouse

    George, David L.; Iverson, Richard M.

    2011-01-01

    Pore-fluid pressure plays a crucial role in debris flows because it counteracts normal stresses at grain contacts and thereby reduces intergranular friction. Pore-pressure feedback accompanying debris deformation is particularly important during the onset of debrisflow motion, when it can dramatically influence the balance of forces governing downslope acceleration. We consider further effects of this feedback by formulating a new, depth-averaged mathematical model that simulates coupled evolution of granular dilatancy, solid and fluid volume fractions, pore-fluid pressure, and flow depth and velocity during all stages of debris-flow motion. To illustrate implications of the model, we use a finite-volume method to compute one-dimensional motion of a debris flow descending a rigid, uniformly inclined slope, and we compare model predictions with data obtained in large-scale experiments at the USGS debris-flow flume. Predictions for the first 1 s of motion show that increasing pore pressures (due to debris contraction) cause liquefaction that enhances flow acceleration. As acceleration continues, however, debris dilation causes dissipation of pore pressures, and this dissipation helps stabilize debris-flow motion. Our numerical predictions of this process match experimental data reasonably well, but predictions might be improved by accounting for the effects of grain-size segregation.

  5. RIPPLE - A new model for incompressible flows with free surfaces

    NASA Technical Reports Server (NTRS)

    Kothe, D. B.; Mjolsness, R. C.

    1991-01-01

    A new free surface flow model, RIPPLE, is summarized. RIPPLE obtains finite difference solutions for incompressible flow problems having strong surface tension forces at free surfaces of arbitrarily complex topology. The key innovation is the continuum surface force model which represents surface tension as a (strongly) localized volume force. Other features include a higher-order momentum advection model, a volume-of-fluid free surface treatment, and an efficient two-step projection solution method. RIPPLE's unique capabilities are illustrated with two example problems: low-gravity jet-induced tank flow, and the collision and coalescence of two cylindrical rods.

  6. Calculation and measurement of the influence of flow parameters on rotordynamic coefficients in labyrinth seals

    NASA Technical Reports Server (NTRS)

    Kwanka, K.; Ortinger, W.; Steckel, J.

    1994-01-01

    First experimental investigations performed on a new test rig are presented. For a staggered labyrinth seal with fourteen cavities the stiffness coefficient and the leakage flow are measured. The experimental results are compared to calculated results which are obtained by a one-volume bulk-flow theory. A perturbation analysis is made for seven terms. It is found out that the friction factors have great impact on the dynamic coefficients. They are obtained by turbulent flow computation by a finite-volume model with the Reynolds equations used as basic equations.

  7. Modeling of Compressible Flow with Friction and Heat Transfer Using the Generalized Fluid System Simulation Program (GFSSP)

    NASA Technical Reports Server (NTRS)

    Bandyopadhyay, Alak; Majumdar, Alok

    2007-01-01

    The present paper describes the verification and validation of a quasi one-dimensional pressure based finite volume algorithm, implemented in Generalized Fluid System Simulation Program (GFSSP), for predicting compressible flow with friction, heat transfer and area change. The numerical predictions were compared with two classical solutions of compressible flow, i.e. Fanno and Rayleigh flow. Fanno flow provides an analytical solution of compressible flow in a long slender pipe where incoming subsonic flow can be choked due to friction. On the other hand, Raleigh flow provides analytical solution of frictionless compressible flow with heat transfer where incoming subsonic flow can be choked at the outlet boundary with heat addition to the control volume. Nonuniform grid distribution improves the accuracy of numerical prediction. A benchmark numerical solution of compressible flow in a converging-diverging nozzle with friction and heat transfer has been developed to verify GFSSP's numerical predictions. The numerical predictions compare favorably in all cases.

  8. Post-fire debris-flow hazard assessment of the area burned by the 2013 Beaver Creek Fire near Hailey, central Idaho

    USGS Publications Warehouse

    Skinner, Kenneth D.

    2013-01-01

    A preliminary hazard assessment was developed for debris-flow hazards in the 465 square-kilometer (115,000 acres) area burned by the 2013 Beaver Creek fire near Hailey in central Idaho. The burn area covers all or part of six watersheds and selected basins draining to the Big Wood River and is at risk of substantial post-fire erosion, such as that caused by debris flows. Empirical models derived from statistical evaluation of data collected from recently burned basins throughout the Intermountain Region in Western United States were used to estimate the probability of debris-flow occurrence, potential volume of debris flows, and the combined debris-flow hazard ranking along the drainage network within the burn area and to estimate the same for analyzed drainage basins within the burn area. Input data for the empirical models included topographic parameters, soil characteristics, burn severity, and rainfall totals and intensities for a (1) 2-year-recurrence, 1-hour-duration rainfall, referred to as a 2-year storm (13 mm); (2) 10-year-recurrence, 1-hour-duration rainfall, referred to as a 10-year storm (19 mm); and (3) 25-year-recurrence, 1-hour-duration rainfall, referred to as a 25-year storm (22 mm). Estimated debris-flow probabilities for drainage basins upstream of 130 selected basin outlets ranged from less than 1 to 78 percent with the probabilities increasing with each increase in storm magnitude. Probabilities were high in three of the six watersheds. For the 25-year storm, probabilities were greater than 60 percent for 11 basin outlets and ranged from 50 to 60 percent for an additional 12 basin outlets. Probability estimates for stream segments within the drainage network can vary within a basin. For the 25-year storm, probabilities for stream segments within 33 basins were higher than the basin outlet, emphasizing the importance of evaluating the drainage network as well as basin outlets. Estimated debris-flow volumes for the three modeled storms range from a minimal debris flow volume of 10 cubic meters [m3]) to greater than 100,000 m3. Estimated debris-flow volumes increased with basin size and distance downstream. For the 25-year storm, estimated debris-flow volumes were greater than 100,000 m3 for 4 basins and between 50,000 and 100,000 m3 for 10 basins. The debris-flow hazard rankings did not result in the highest hazard ranking of 5, indicating that none of the basins had a high probability of debris-flow occurrence and a high debris-flow volume estimate. The hazard ranking was 4 for one basin using the 10-year-recurrence storm model and for three basins using the 25-year-recurrence storm model. The maps presented herein may be used to prioritize areas where post-wildfire remediation efforts should take place within the 2- to 3-year period of increased erosional vulnerability.

  9. Experimental constraints on the outgassing dynamics of basaltic magmas

    NASA Astrophysics Data System (ADS)

    Pioli, L.; Bonadonna, C.; Azzopardi, B. J.; Phillips, J. C.; Ripepe, M.

    2012-03-01

    The dynamics of separated two-phase flow of basaltic magmas in cylindrical conduits has been explored combining large-scale experiments and theoretical studies. Experiments consisted of the continuous injection of air into water or glucose syrup in a 0.24 m diameter, 6.5 m long bubble column. The model calculates vesicularity and pressure gradient for a range of gas superficial velocities (volume flow rates/pipe area, 10-2-102 m/s), conduit diameters (100-2 m), and magma viscosities (3-300 Pa s). The model is calibrated with the experimental results to extrapolate key flow parameters such as Co (distribution parameter) and Froude number, which control the maximum vesicularity of the magma in the column, and the gas rise speed of gas slugs. It predicts that magma vesicularity increases with increasing gas volume flow rate and decreases with increasing conduit diameter, until a threshold value (45 vol.%), which characterizes churn and annular flow regimes. Transition to annular flow regimes is expected to occur at minimum gas volume flow rates of 103-104 m3/s. The vertical pressure gradient decreases with increasing gas flow rates and is controlled by magma vesicularity (in bubbly flows) or the length and spacing of gas slugs. This study also shows that until conditions for separated flow are met, increases in magma viscosity favor stability of slug flow over bubbly flow but suggests coexistence between gas slugs and small bubbles, which contribute to a small fraction of the total gas outflux. Gas flow promotes effective convection of the liquid, favoring magma homogeneity and stable conditions.

  10. Application of artificial neural networks for the prediction of volume fraction using spectra of gamma rays backscattered by three-phase flows

    NASA Astrophysics Data System (ADS)

    Gholipour Peyvandi, R.; Islami Rad, S. Z.

    2017-12-01

    The determination of the volume fraction percentage of the different phases flowing in vessels using transmission gamma rays is a conventional method in petroleum and oil industries. In some cases, with access only to the one side of the vessels, attention was drawn toward backscattered gamma rays as a desirable choice. In this research, the volume fraction percentage was measured precisely in water-gasoil-air three-phase flows by using the backscatter gamma ray technique andthe multilayer perceptron (MLP) neural network. The volume fraction determination in three-phase flows requires two gamma radioactive sources or a dual-energy source (with different energies) while in this study, we used just a 137Cs source (with the single energy) and a NaI detector to analyze backscattered gamma rays. The experimental set-up provides the required data for training and testing the network. Using the presented method, the volume fraction was predicted with a mean relative error percentage less than 6.47%. Also, the root mean square error was calculated as 1.60. The presented set-up is applicable in some industries with limited access. Also, using this technique, the cost, radiation safety and shielding requirements are minimized toward the other proposed methods.

  11. Probability and volume of potential postwildfire debris flows in the 2012 Waldo Canyon Burn Area near Colorado Springs, Colorado

    USGS Publications Warehouse

    Verdin, Kristine L.; Dupree, Jean A.; Elliott, John G.

    2012-01-01

    This report presents a preliminary emergency assessment of the debris-flow hazards from drainage basins burned by the 2012 Waldo Canyon fire near Colorado Springs in El Paso County, Colorado. Empirical models derived from statistical evaluation of data collected from recently burned basins throughout the intermountain western United States were used to estimate the probability of debris-flow occurrence and potential volume of debris flows along the drainage network of the burned area and to estimate the same for 22 selected drainage basins along U.S. Highway 24 and the perimeter of the burned area. Input data for the models included topographic parameters, soil characteristics, burn severity, and rainfall totals and intensities for a (1) 2-year-recurrence, 1-hour-duration rainfall, referred to as a 2-year storm (29 millimeters); (2) 10-year-recurrence, 1-hour-duration rainfall, referred to as a 10-year storm (42 millimeters); and (3) 25-year-recurrence, 1-hour-duration rainfall, referred to as a 25-year storm (48 millimeters). Estimated debris-flow probabilities at the pour points of the the drainage basins of interest ranged from less than 1 to 54 percent in response to the 2-year storm; from less than 1 to 74 percent in response to the 10-year storm; and from less than 1 to 82 percent in response to the 25-year storm. Basins and drainage networks with the highest probabilities tended to be those on the southern and southeastern edge of the burn area where soils have relatively high clay contents and gradients are steep. Nine of the 22 drainage basins of interest have greater than a 40-percent probability of producing a debris flow in response to the 10-year storm. Estimated debris-flow volumes for all rainfalls modeled range from a low of 1,500 cubic meters to a high of greater than 100,000 cubic meters. Estimated debris-flow volumes increase with basin size and distance along the drainage network, but some smaller drainages were also predicted to produce substantial volumes of material. The predicted probabilities and some of the volumes predicted for the modeled storms indicate a potential for substantial debris-flow impacts on structures, reservoirs, roads, bridges, and culverts located both within and immediately downstream from the burned area. U.S. Highway 24, on the southern edge of the burn area, is also susceptible to impacts from debris flows.

  12. Intraoperative Evaluation of Reverse Bypass Using a Naturally Formed "Bonnet" Superficial Temporal Artery: Technical Note.

    PubMed

    Nagm, Alhusain; Horiuchi, Tetsuyoshi; Hasegawa, Takatoshi; Hongo, Kazuhiro

    2016-04-01

    In reverse bypass that used a naturally formed "bonnet" superficial temporal artery, intraoperative volume flow measurement quantifies flow augmentation after revascularization, confirms flow preservation, and identifies inadvertent vessel compromise. A 75-year-old man presented with transient ischemic attacks attributed to right internal carotid artery stenosis. He underwent successful reverse bypass via a naturally formed "bonnet" superficial temporal artery middle cerebral artery bypass. As the result of proper intraoperative volume flow evaluation, a successful reverse bypass was achieved. Modification of the intraoperative stroke risk and prediction of the long-term patency after reverse bypass can be achieved by meticulous intraoperative blood flow evaluation. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. The morphology and evolution of the Stromboli 2002-2003 lava flow field--An example of a basaltic flow field emplaced on a steep slope

    USGS Publications Warehouse

    Lodato, Luigi; Harris, A.; Spampinato, L.; Calvari, Sonia; Dehn, J.; Patrick, M.

    2007-01-01

    The use of a hand-held thermal camera during the 2002–2003 Stromboli effusive eruption proved essential in tracking the development of flow field structures and in measuring related eruption parameters, such as the number of active vents and flow lengths. The steep underlying slope on which the flow field was emplaced resulted in a characteristic flow field morphology. This comprised a proximal shield, where flow stacking and inflation caused piling up of lava on the relatively flat ground of the vent zone, that fed a medial–distal lava flow field. This zone was characterized by the formation of lava tubes and tumuli forming a complex network of tumuli and flows linked by tubes. Most of the flow field was emplaced on extremely steep slopes and this had two effects. It caused flows to slide, as well as flow, and flow fronts to fail frequently, persistent flow front crumbling resulted in the production of an extensive debris field. Channel-fed flows were also characterized by development of excavated debris levees in this zone (Calvari et al. 2005). Collapse of lava flow fronts and inflation of the upper proximal lava shield made volume calculation very difficult. Comparison of the final field volume with that expecta by integrating the lava effusion rates through time suggests a loss of ~70% erupted lava by flow front crumbling and accumulation as debris flows below sea level. Derived relationships between effusion rate, flow length, and number of active vents showed systematic and correlated variations with time where spreading of volume between numerous flows caused an otherwise good correlation between effusion rate, flow length to break down. Observations collected during this eruption are useful in helping to understand lava flow processes on steep slopes, as well as in interpreting old lava–debris sequences found in other steep-sided volcanoes subject to effusive activity.

  14. The impact of maternal plasma volume expansion and antihypertensive treatment with intravenous dihydralazine on fetal and maternal hemodynamics during pre-eclampsia: a clinical, echo-Doppler and viscometric study.

    PubMed

    Boito, S M E; Struijk, P C; Pop, G A M; Visser, W; Steegers, E A P; Wladimiroff, J W

    2004-04-01

    To establish the effects of plasma volume expansion (PVE) followed by intravenous dihydralazine (DH) administration on maternal whole blood viscosity (WBV) and hematocrit, uteroplacental and fetoplacental downstream impedance and umbilical venous (UV) volume flow in pre-eclampsia. In 13 pre-eclamptic women maternal and fetal hemodynamics were established by means of combined measurement of maternal arterial blood pressure (BP), WBV, hematocrit and uterine artery (UtA) resistance index (RI) in addition to umbilical artery (UA) pulsatility index (PI) and UV volume flow obtained from UV vessel area and UV time-averaged flow velocity. In each woman all parameters were measured four times at baseline, after PVE, after DH and 24 h after the start of treatment. Maternal diastolic BP, hematocrit and WBV display a significant reduction after PVE. In the fetus UA PI decreases significantly whereas a significant increase in UV cross-sectional area was detected. After maternal DH administration, arterial systolic and diastolic BP and UA PI show a significant decrease compared with the measurements following PVE. At 24 h, only maternal systolic and diastolic BP display a significant further decrease. No significant changes were established for the UtA RI, UV time-averaged velocity and UV volume flow during the entire study period. During pre-eclampsia, maternal PVE followed by DH administration results in a significant reduction in maternal diastolic BP, maternal hematocrit and WBV. Maternal PVE is associated with a significant increase in UV cross-sectional area and a non-significant rise of 11% in UV volume flow. Maternal DH administration does not result in any change in UV cross-sectional area. However, UA PI decreases significantly after both PVE and DH treatment. Copyright 2004 ISUOG.

  15. Postwildfire debris-flow hazard assessment of the area burned by the 2012 Little Bear Fire, south-central New Mexico

    USGS Publications Warehouse

    Tillery, Anne C.; Matherne, Anne Marie

    2013-01-01

    A preliminary hazard assessment was developed of the debris-flow potential from 56 drainage basins burned by the Little Bear Fire in south-central New Mexico in June 2012. The Little Bear Fire burned approximately 179 square kilometers (km2) (44,330 acres), including about 143 km2 (35,300 acres) of National Forest System lands of the Lincoln National Forest. Within the Lincoln National Forest, about 72 km2 (17,664 acres) of the White Mountain Wilderness were burned. The burn area also included about 34 km2 (8,500 acres) of private lands. Burn severity was high or moderate on 53 percent of the burn area. The area burned is at risk of substantial postwildfire erosion, such as that caused by debris flows and flash floods. A postwildfire debris-flow hazard assessment of the area burned by the Little Bear Fire was performed by the U.S. Geological Survey in cooperation with the U.S. Department of Agriculture Forest Service, Lincoln National Forest. A set of two empirical hazard-assessment models developed by using data from recently burned drainage basins throughout the intermountain Western United States was used to estimate the probability of debris-flow occurrence and volume of debris flows along the burn area drainage network and for selected drainage basins within the burn area. The models incorporate measures of areal burn extent and severity, topography, soils, and storm rainfall intensity to estimate the probability and volume of debris flows following the fire. Relative hazard rankings of postwildfire debris flows were produced by summing the estimated probability and volume ranking to illustrate those areas with the highest potential occurrence of debris flows with the largest volumes. The probability that a drainage basin could produce debris flows and the volume of a possible debris flow at the basin outlet were estimated for three design storms: (1) a 2-year-recurrence, 30-minute-duration rainfall of 27 millimeters (mm) (a 50 percent chance of occurrence in any given year); (2) a 10-year-recurrence, 30-minute-duration rainfall of 42 mm (a 10 percent chance of occurrence in any given year); and (3) a 25-year-recurrence, 30-minute-duration rainfall of 51 mm (a 4 percent chance of occurrence in any given year). Thirty-nine percent of the 56 drainage basins modeled have a high (greater than 80 percent) probability of debris flows in response to the 2-year design storm; 80 percent of the modeled drainage basins have a high probability of debris flows in response to the 25-year design storm. For debris-flow volume, 7 percent of the modeled drainage basins have an estimated debris-flow volume greater than 100,000 cubic meters (m3) in response to the 2-year design storm; 9 percent of the drainage basins are included in the greater than 100,000 m3 category for both the 10-year and the 25-year design storms. Drainage basins in the greater than 100,000 m3 volume category also received the highest combined hazard ranking. The maps presented herein may be used to prioritize areas where emergency erosion mitigation or other protective measures may be needed prior to rainstorms within these drainage basins, their outlets, or areas downstream from these drainage basins within the 2- to 3-year period of vulnerability. This work is preliminary and is subject to revision. The assessment herein is provided on the condition that neither the U.S. Geological Survey nor the U.S. Government may be held liable for any damages resulting from the authorized or unauthorized use of the assessment.

  16. A Mixed Finite Volume Element Method for Flow Calculations in Porous Media

    NASA Technical Reports Server (NTRS)

    Jones, Jim E.

    1996-01-01

    A key ingredient in the simulation of flow in porous media is the accurate determination of the velocities that drive the flow. The large scale irregularities of the geology, such as faults, fractures, and layers suggest the use of irregular grids in the simulation. Work has been done in applying the finite volume element (FVE) methodology as developed by McCormick in conjunction with mixed methods which were developed by Raviart and Thomas. The resulting mixed finite volume element discretization scheme has the potential to generate more accurate solutions than standard approaches. The focus of this paper is on a multilevel algorithm for solving the discrete mixed FVE equations. The algorithm uses a standard cell centered finite difference scheme as the 'coarse' level and the more accurate mixed FVE scheme as the 'fine' level. The algorithm appears to have potential as a fast solver for large size simulations of flow in porous media.

  17. A discontinuous control volume finite element method for multi-phase flow in heterogeneous porous media

    NASA Astrophysics Data System (ADS)

    Salinas, P.; Pavlidis, D.; Xie, Z.; Osman, H.; Pain, C. C.; Jackson, M. D.

    2018-01-01

    We present a new, high-order, control-volume-finite-element (CVFE) method for multiphase porous media flow with discontinuous 1st-order representation for pressure and discontinuous 2nd-order representation for velocity. The method has been implemented using unstructured tetrahedral meshes to discretize space. The method locally and globally conserves mass. However, unlike conventional CVFE formulations, the method presented here does not require the use of control volumes (CVs) that span the boundaries between domains with differing material properties. We demonstrate that the approach accurately preserves discontinuous saturation changes caused by permeability variations across such boundaries, allowing efficient simulation of flow in highly heterogeneous models. Moreover, accurate solutions are obtained at significantly lower computational cost than using conventional CVFE methods. We resolve a long-standing problem associated with the use of classical CVFE methods to model flow in highly heterogeneous porous media.

  18. Radial flow nuclear thermal rocket (RFNTR)

    DOEpatents

    Leyse, Carl F.

    1995-11-07

    A radial flow nuclear thermal rocket fuel assembly includes a substantially conical fuel element having an inlet side and an outlet side. An annular channel is disposed in the element for receiving a nuclear propellant, and a second, conical, channel is disposed in the element for discharging the propellant. The first channel is located radially outward from the second channel, and separated from the second channel by an annular fuel bed volume. This fuel bed volume can include a packed bed of loose fuel beads confined by a cold porous inlet frit and a hot porous exit frit. The loose fuel beads include ZrC coated ZrC-UC beads. In this manner, nuclear propellant enters the fuel assembly axially into the first channel at the inlet side of the element, flows axially across the fuel bed volume, and is discharged from the assembly by flowing radially outward from the second channel at the outlet side of the element.

  19. Radial flow nuclear thermal rocket (RFNTR)

    DOEpatents

    Leyse, Carl F.

    1995-01-01

    A radial flow nuclear thermal rocket fuel assembly includes a substantially conical fuel element having an inlet side and an outlet side. An annular channel is disposed in the element for receiving a nuclear propellant, and a second, conical, channel is disposed in the element for discharging the propellant. The first channel is located radially outward from the second channel, and separated from the second channel by an annular fuel bed volume. This fuel bed volume can include a packed bed of loose fuel beads confined by a cold porous inlet frit and a hot porous exit frit. The loose fuel beads include ZrC coated ZrC-UC beads. In this manner, nuclear propellant enters the fuel assembly axially into the first channel at the inlet side of the element, flows axially across the fuel bed volume, and is discharged from the assembly by flowing radially outward from the second channel at the outlet side of the element.

  20. Drift stabilizer for reciprocating free-piston devices

    DOEpatents

    Ward, William C.; Corey, John A.; Swift, Gregory W.

    2003-05-20

    A free-piston device has a stabilized piston drift. A piston having a frequency of reciprocation over a stroke length and with first and second sides facing first and second variable volumes, respectively, for containing a working fluid defining an acoustic wavelength at the frequency of reciprocation. A bypass tube waveguide connects the first and second variable volumes at all times during reciprocation of the piston. The waveguide has a relatively low impedance for steady flow and a relatively high impedance for oscillating flow at the frequency of reciprocation of the piston, so that steady flow returns fluid leakage from about the piston between the first and second volumes while oscillating flow is not diverted through the waveguide. Thus, net leakage about the piston is returned during each stroke of the piston while oscillating leakage is not allowed and pressure buildup on either the first or second side of the piston is avoided to provide a stable piston location.

  1. Mobility of pyroclastic flows and surges at the Soufriere Hills Volcano, Montserrat

    USGS Publications Warehouse

    Calder, E.S.; Cole, P.D.; Dade, W.B.; Druitt, T.H.; Hoblitt, R.P.; Huppert, H.E.; Ritchie, L.; Sparks, R.S.J.; Young, S.R.

    1999-01-01

    The Soufriere Hills Volcano on Montserrat has produced avalanche-like pyroclastic flows formed by collapse of the unstable lava dome or explosive activity. Pyroclastic flows associated with dome collapse generate overlying dilute surges which detach from and travel beyond their parent flows. The largest surges partially transform by rapid sedimentation into dense secondary pyroclastic flows that pose significant hazards to distal areas. Different kinds of pyroclastic density currents display contrasting mobilities indicated by ratios of total height of fall H, run-out distance L, area inundated A and volume transported V. Dome-collapse flow mobilities (characterised by either L/H or A/V 2/3) resemble those of terrestrial and extraterrestrial cold-rockfalls (Dade and Huppert, 1998). In contrast, fountain-fed pumice flows and fine-grained, secondary pyroclastic flows travel slower but, for comparable initial volumes and heights, can inundate greater areas.

  2. Dispersion of a Nanoliter Bolus in Microfluidic Co-Flow.

    PubMed

    Conway, A J; Saadi, W M; Sinatra, F L; Kowalski, G; Larson, D; Fiering, J

    2014-03-01

    Microfluidic systems enable reactions and assays on the scale of nanoliters. However, at this scale nonuniformities in sample delivery become significant. To determine the fundamental minimum sample volume required for a particular device, a detailed understanding of mass transport is required. Co-flowing laminar streams are widely used in many devices, but typically only in the steady-state. Because establishing the co-flow steady-state consumes excess sample volume and time, there is a benefit to operating devices in the transient state, which predominates as the volume of the co-flow reactor decreases. Analysis of the co-flow transient has been neglected thus far. In this work we describe the fabrication of a pneumatically controlled microfluidic injector constructed to inject a discrete 50nL bolus into one side of a two-stream co-flow reactor. Using dye for image analysis, injections were performed at a range of flow rates from 0.5-10μL/min, and for comparison we collected the co-flow steady-state data for this range. The results of the image analysis were also compared against theory and simulations for device validation. For evaluation, we established a metric that indicates how well the mass distribution in the bolus injection approximates steady-state co-flow. Using such analysis, transient-state injections can approximate steady-state conditions within predefined errors, allowing straight forward measurements to be performed with reduced reagent consumption.

  3. Emergency assessment of post-fire debris-flow hazards for the 2013 Rim Fire, Stanislaus National Forest and Yosemite National Park, California

    USGS Publications Warehouse

    Staley, Dennis M.

    2013-01-01

    Wildfire can significantly alter the hydrologic response of a watershed to the extent that even modest rainstorms can produce dangerous flash floods and debris flows. In this report, empirical models are used to predict the probability and magnitude of debris-flow occurrence in response to a 10-year rainstorm for the 2013 Rim fire in Yosemite National Park and the Stanislaus National Forest, California. Overall, the models predict a relatively high probability (60–80 percent) of debris flow for 28 of the 1,238 drainage basins in the burn area in response to a 10-year recurrence interval design storm. Predictions of debris-flow volume suggest that debris flows may entrain a significant volume of material, with 901 of the 1,238 basins identified as having potential debris-flow volumes greater than 10,000 cubic meters. These results of the relative combined hazard analysis suggest there is a moderate likelihood of significant debris-flow hazard within and downstream of the burn area for nearby populations, infrastructure, wildlife, and water resources. Given these findings, we recommend that residents, emergency managers, and public works departments pay close attention to weather forecasts and National-Weather-Service-issued Debris Flow and Flash Flood Outlooks, Watches and Warnings and that residents adhere to any evacuation orders.

  4. Diaphragmatic mobility in healthy subjects during incentive spirometry with a flow-oriented device and with a volume-oriented device.

    PubMed

    Yamaguti, Wellington Pereira dos Santos; Sakamoto, Eliana Takahama; Panazzolo, Danilo; Peixoto, Corina da Cunha; Cerri, Giovanni Guido; Albuquerque, André Luis Pereira

    2010-01-01

    To compare the diaphragmatic mobility of healthy subjects during incentive spirometry with a volume-oriented device, during incentive spirometry with a flow-oriented device, and during diaphragmatic breathing. To compare men and women in terms of diaphragmatic mobility during these three types of breathing exercises. We evaluated the pulmonary function and diaphragmatic mobility of 17 adult healthy volunteers (9 women and 8 men). Diaphragmatic mobility was measured via ultrasound during diaphragmatic breathing and during the use of the two types of incentive spirometers. Diaphragmatic mobility was significantly greater during the use of the volume-oriented incentive spirometer than during the use of the flow-oriented incentive spirometer (70.16 ± 12.83 mm vs. 63.66 ± 10.82 mm; p = 0.02). Diaphragmatic breathing led to a greater diaphragmatic mobility than did the use of the flow-oriented incentive spirometer (69.62 ± 11.83 mm vs. 63.66 ± 10.82 mm; p = 0.02). During all three types of breathing exercises, the women showed a higher mobility/FVC ratio than did the men. Incentive spirometry with a volume-oriented device and diaphragmatic breathing promoted greater diaphragmatic mobility than did incentive spirometry with a flow-oriented device. Women performed better on the three types of breathing exercises than did men.

  5. Decreased cerebral perfusion in Duchenne muscular dystrophy patients.

    PubMed

    Doorenweerd, Nathalie; Dumas, Eve M; Ghariq, Eidrees; Schmid, Sophie; Straathof, Chiara S M; Roest, Arno A W; Wokke, Beatrijs H; van Zwet, Erik W; Webb, Andrew G; Hendriksen, Jos G M; van Buchem, Mark A; Verschuuren, Jan J G M; Asllani, Iris; Niks, Erik H; van Osch, Matthias J P; Kan, Hermien E

    2017-01-01

    Duchenne muscular dystrophy is caused by dystrophin gene mutations which lead to the absence of the protein dystrophin. A significant proportion of patients suffer from learning and behavioural disabilities, in addition to muscle weakness. We have previously shown that these patients have a smaller total brain and grey matter volume, and altered white matter microstructure compared to healthy controls. Patients with more distal gene mutations, predicted to affect dystrophin isoforms Dp140 and Dp427, showed greater grey matter reduction. Now, we studied if cerebral blood flow in Duchenne muscular dystrophy patients is altered, since cerebral expression of dystrophin also occurs in vascular endothelial cells and astrocytes associated with cerebral vasculature. T1-weighted anatomical and pseudo-continuous arterial spin labeling cerebral blood flow images were obtained from 26 patients and 19 age-matched controls (ages 8-18 years) on a 3 tesla MRI scanner. Group comparisons of cerebral blood flow were made with and without correcting for grey matter volume using partial volume correction. Results showed that patients had a lower cerebral blood flow than controls (40.0 ± 6.4 and 47.8 ± 6.3 mL/100 g/min respectively, p = 0.0002). This reduction was independent of grey matter volume, suggesting that they are two different aspects of the pathophysiology. Cerebral blood flow was lowest in patients lacking Dp140. There was no difference in CBF between ambulant and non-ambulant patients. Only three patients showed a reduced left ventricular ejection fraction. No correlation between cerebral blood flow and age was found. Our results indicate that cerebral perfusion is reduced in Duchenne muscular dystrophy patients independent of the reduced grey matter volume. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. The application of finite volume methods for modelling three-dimensional incompressible flow on an unstructured mesh

    NASA Astrophysics Data System (ADS)

    Lonsdale, R. D.; Webster, R.

    This paper demonstrates the application of a simple finite volume approach to a finite element mesh, combining the economy of the former with the geometrical flexibility of the latter. The procedure is used to model a three-dimensional flow on a mesh of linear eight-node brick (hexahedra). Simulations are performed for a wide range of flow problems, some in excess of 94,000 nodes. The resulting computer code ASTEC that incorporates these procedures is described.

  7. NASA Non-Flow-Through PEM Fuel Cell System for Aerospace Applications

    NASA Technical Reports Server (NTRS)

    Araghi, Koorosh R.

    2011-01-01

    NASA is researching passive NFT Proton Exchange Membrane (PEM) fuel cell technologies for primary fuel cell power plants in air-independent applications. NFT fuel cell power systems have a higher power density than flow through systems due to both reduced parasitic loads and lower system mass and volume. Reactant storage still dominates system mass/volume considerations. NFT fuel cell stack testing has demonstrated equivalent short term performance to flow through stacks. More testing is required to evaluate long-term performance.

  8. The 1984 Mauna Loa eruption and planetary geolgoy

    NASA Technical Reports Server (NTRS)

    Moore, Henry J.

    1987-01-01

    In planetary geology, lava flows on the Moon and Mars are commonly treated as relatively simple systems. Some of the complexities of actual lava flows are illustrated using the main flow system of the 1984 Mauna Loa eruption. The outline, brief narrative, and results given are based on a number of sources. The implications of the results to planetary geology are clear. Volume flow rates during an eruption depend, in part, on the volatile content of the lava. These differ from the volume flow rates calculated from post eruption flow dimensions and the duration of the eruption and from those using models that assume a constant density. Mass flow rates might be more appropriate because the masses of volatiles in lavas are usually small, but variable and sometimes unknown densities impose severe restrictions on mass estimates.

  9. Estimation of truck volumes and flows

    DOT National Transportation Integrated Search

    2004-08-01

    This research presents a statistical approach for estimating truck volumes, based : primarily on classification counts and information on roadway functionality, employment, : sales volume and number of establishments within the state. Models have bee...

  10. Influence of Gravity on Blood Volume and Flow Distribution

    NASA Technical Reports Server (NTRS)

    Pendergast, D.; Olszowka, A.; Bednarczyk, E.; Shykoff, B.; Farhi, L.

    1999-01-01

    In our previous experiments during NASA Shuttle flights SLS 1 and 2 (9-15 days) and EUROMIR flights (30-90 days) we observed that pulmonary blood flow (cardiac output) was elevated initially, and surprisingly remained elevated for the duration of the flights. Stroke volume increased initially and then decreased, but was still above 1 Gz values. As venous return was constant, the changes in SV were secondary to modulation of heart rate. Mean blood pressure was at or slightly below 1 Gz levels in space, indicating a decrease in total peripheral resistance. It has been suggested that plasma volume is reduced in space, however cardiac output/venous return do not return to 1 Gz levels over the duration of flight. In spite of the increased cardiac output, central venous pressure was not elevated in space. These data suggest that there is a change in the basic relationship between cardiac output and central venous pressure, a persistent "hyperperfusion" and a re-distribution of blood flow and volume during space flight. Increased pulmonary blood flow has been reported to increase diffusing capacity in space, presumably due to the improved homogeneity of ventilation and perfusion. Other studies have suggested that ventilation may be independent of gravity, and perfusion may not be gravity- dependent. No data for the distribution of pulmonary blood volume were available for flight or simulated microgravity. Recent studies have suggested that the pulmonary vascular tree is influenced by sympathetic tone in a manner similar to that of the systemic system. This implies that the pulmonary circulation is dilated during microgravity and that the distribution of blood flow and volume may be influenced more by vascular control than by gravity. The cerebral circulation is influenced by sympathetic tone similarly to that of the systemic and pulmonary circulations; however its effects are modulated by cerebral autoregulation. Thus it is difficult to predict if cerebral perfusion is increased and if there is edema in space. Anecdotal evidence suggests there may be cerebral edema early in flight. Cerebral artery velocity has been shown to be elevated in simulated microgravity. The elevated cerebral artery velocity during simulated microgravity may reflect vasoconstriction of the arteries and not increased cerebral blood flow. The purpose of our investigations was to evaluate the effects of alterations in simulated gravity (+/-), resulting in changes in cardiac output (+/-), and on the blood flow and volume distribution in the lung and brain of human subjects. The first hypothesis of these studies was that blood flow and volume would be affected by gravity, but their distribution in the lung would be independent of gravity and due to vasoactivity changing vascular resistance in lung vessels. The vasodilitation of the lung vasculature (lower resistance) along with increased "compliance" of the heart could account for the absence of increased central venous pressure in microgravity. Secondly, we postulate that cerebral blood velocity is increased in microgravity due to large artery vasoconstriction, but that cerebral blood flow would be reduced due to autoregulation.

  11. The enormous Chillos Valley Lahar: An ash-flow-generated debris flow from Cotopaxi Volcano, Ecuador

    USGS Publications Warehouse

    Mothes, P.A.; Hall, M.L.; Janda, R.J.

    1998-01-01

    The Chillos Valley Lahar (CVL), the largest Holocene debris flow in area and volume as yet recognized in the northern Andes, formed on Cotopaxi volcano's north and northeast slopes and descended river systems that took it 326 km north-northwest to the Pacific Ocean and 130+ km east into the Amazon basin. In the Chillos Valley, 40 km downstream from the volcano, depths of 80-160 m and valley cross sections up to 337000m2 are observed, implying peak flow discharges of 2.6-6.0 million m3/s. The overall volume of the CVL is estimated to be ???3.8 km3. The CVL was generated approximately 4500 years BP by a rhyolitic ash flow that followed a small sector collapse on the north and northeast sides of Cotopaxi, which melted part of the volcano's icecap and transformed rapidly into the debris flow. The ash flow and resulting CVL have identical components, except for foreign fragments picked up along the flow path. Juvenile materials, including vitric ash, crystals, and pumice, comprise 80-90% of the lahar's deposit, whereas rhyolitic, dacitic, and andesitic lithics make up the remainder. The sand-size fraction and the 2- to 10-mm fraction together dominate the deposit, constituting ???63 and ???15 wt.% of the matrix, respectively, whereas the silt-size fraction averages less than ???10 wt.% and the clay-size fraction less than 0.5 wt.%. Along the 326-km runout, these particle-size fractions vary little, as does the sorting coefficient (average = 2.6). There is no tendency toward grading or improved sorting. Limited bulking is recognized. The CVL was an enormous non-cohesive debris flow, notable for its ash-flow origin and immense volume and peak discharge which gave it characteristics and a behavior akin to large cohesive mudflows. Significantly, then, ash-flow-generated debris flows can also achieve large volumes and cover great areas; thus, they can conceivably affect large populated regions far from their source. Especially dangerous, therefore, are snowclad volcanoes with recent silicic ash-flow histories such as those found in the Andes and Alaska.

  12. Triggering conditions and mobility of debris flows associated to complex earthflows

    NASA Astrophysics Data System (ADS)

    Malet, J.-P.; Laigle, D.; Remaître, A.; Maquaire, O.

    2005-03-01

    Landslides on black marl slopes of the French Alps are, in most cases, complex catastrophic failures in which the initial structural slides transform into slow-moving earthflows. Under specific hydrological conditions, these earthflows can transform into debris flows. Due to their sediment volume and their high mobility, debris flow induced by landslides are far much dangerous than these resulting from continuous erosive processes. A fundamental point to correctly delineate the area exposed to debris flows on the alluvial fans is therefore to understand why and how some earthflows transform into debris flow while most of them stabilize. In this paper, a case of transformation from earthflow to debris flow is presented and analysed. An approach combining geomorphology, hydrology, geotechnics and rheology is adopted to model the debris flow initiation (failure stage) and its runout (postfailure stage). Using the Super-Sauze earthflow (Alpes-de-Haute-Provence, France) as a case study, the objective is to characterize the hydrological and mechanical conditions leading to debris flow initiation in such cohesive material. Results show a very good agreement between the observed runout distances and these calculated using the debris flow modeling code Cemagref 1-D. The deposit thickness in the depositional area and the velocities of the debris flows are also well reproduced. Furthermore, a dynamic slope stability analysis shows that conditions in the debris source area under average pore water pressures and moisture contents are close to failure. A small excess of water can therefore initiate failure. Seepage analysis is used to estimate the volume of debris that can be released for several hydroclimatic conditions. The failed volumes are then introduced in the Cemagref 1-D runout code to propose debris flow hazard scenarios. Results show that clayey earthflow can transform under 5-year return period rainfall conditions into 1-km runout debris flow of volumes ranging between 2000 to 5000 m 3. Slope failures induced by 25-year return period rainfall can trigger large debris flow events (30,000 to 50,000 m 3) that can reach the alluvial fan and cause damage.

  13. Reversed aqueductal cerebrospinal fluid net flow in idiopathic normal pressure hydrocephalus.

    PubMed

    Yin, L K; Zheng, J J; Zhao, L; Hao, X Z; Zhang, X X; Tian, J Q; Zheng, K; Yang, Y M

    2017-11-01

    The changes of CSF flow dynamics in idiopathic normal pressure hydrocephalus (iNPH) are not fully elucidated. Most previous studies took the whole cardiac cycle as a unit. In this work, it is divided into systole and diastole phase and compared between iNPH patients and normal elderly and paid special attention to the change of netflow direction. Twenty iNPH patients according to international guideline and twenty healthy volunteers were included in this study and examined by MRI. Three categories of CSF flow parameters were measured: peak velocity (V peak ), stroke volume (SV), and minute flow volume (MinV) covering the whole cycle; peak velocity (V peak-s , V peak-d ) and flow volume (Vol s , Vol d ) of the systole and diastole, respectively; net flow. Evans index (EI) was also measured and compared statistically between the two groups. EI, V peak , SV, MinV, Vol s , Vol d , and V peak-d significantly increased in iNPH group (P<0.05). V peak-s of the two groups were not significantly different (P>0.05). The net flow of 16 iNPH patients (16/20) was in the caudo-cranial direction, while 15 volunteers (15/20) were in the opposite direction, which showed statistically significant differences (P=.001). INPH patients present hyperdynamic flow with increased velocity and volume both in systole and diastole phase. Degree of rising in diastole phase exceeds that of systole phase. The resulting reversal of netflow direction may play a key role in the occurrence of ventriculomegaly in iNPH patients. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Puffing Topography and Nicotine Intake of Electronic Cigarette Users

    PubMed Central

    Behar, Rachel Z.; Hua, My; Talbot, Prue

    2015-01-01

    Background Prior electronic cigarette (EC) topography data are based on two video analyses with limited parameters. Alternate methods for measuring topography are needed to understand EC use and nicotine intake. Objectives This study evaluated EC topography with a CReSS Pocket device and quantified nicotine intake. Methods Validation tests on pressure drop, flow rate, and volume confirmed reliable performance of the CReSS Pocket device. Twenty participants used Blu Cigs and V2 Cigs for 10 minute intervals with a 10–15 minute break between brands. Brand order was reversed and repeated within 7 days Data were analyzed to determine puff duration, puff count, volume, flow rate, peak flow, and inter-puff interval. Nicotine intake was estimated from cartomizer fluid consumption and topography data. Results Nine patterns of EC use were identified. The average puff count and inter-puff interval were 32 puffs and 17.9 seconds. All participants, except one, took more than 20 puffs/10 minutes. The averages for puff duration (2.65 seconds/puff), volume/puff (51ml/puff), total puff volume (1,579 ml), EC fluid consumption (79.6 mg), flow rate (20 ml/s), and peak flow rate (27 ml/s) were determined for 10-minute sessions. All parameters except total puff count were significantly different for Blu versus V2 EC. Total volume for Blu versus V2 was four-times higher than for conventional cigarettes. Average nicotine intake for Blu and V2 across both sessions was 1.2 ± 0.5 mg and 1.4 ± 0.7 mg, respectively, which is similar to conventional smokers. Conclusions EC puffing topography was variable among participants in the study, but often similar within an individual between brands or days. Puff duration, inter-puff interval, and puff volume varied from conventional cigarette standards. Data on total puff volume and nicotine intake are consistent with compensatory usage of EC. These data can contribute to the development of a standard protocol for laboratory testing of EC products. PMID:25664463

  15. Maple sap uptake, exudation, and pressure changes correlated with freezing exotherms and thawing endotherms.

    PubMed

    Tyree, M T

    1983-10-01

    Sap flow rates and sap pressure changes were measured in dormant sugar maple trees (Acer saccharum Marsh.). In the forest, sap flow rates and pressure changes were measured from tap holes drilled into tree trunks in mature trees and sap flow rates were measured from the base of excised branches. Excised branches were also brought into the laboratory where air temperature could be carefully controlled in a refrigerated box and sap flow rates and sap pressures were measured from the cut base of the branches.Under both forest and laboratory conditions, sap uptake occurred as the wood temperature declined but much more rapid sap uptake correlated with the onset of the freezing exotherm. When sap pressures were measured under conditions of negligible volume displacement, the sap pressure rapidly fell to -60 to -80 kilopascals at the start of the freezing exotherm. The volume of water uptake and the rate of uptake depended on the rate of freezing. A slow freezing rate correlated with a large volume of water uptake, a fast freezing rate induced a smaller volume of water uptake. The volume of water uptake ranged from 0.02 to 0.055 grams water per gram dry weight of sapwood. The volume of water exuded after thawing was usually less than the volume of uptake so that after several freezing and thawing cycles the sapwood water content increased from 0.7 to 0.8 grams water per gram dry weight.These results are discussed in terms of a physical model of the mechanism of maple sap uptake and exudation first proposed by P. E. R. O'Malley. The proposed mechanism of sap uptake is by vapor distillation in air filled wood fiber lumina during the freezing of minor branches. Gravity and pressurized air bubbles (compressed during freezing) cause sap flow from the canopy down the tree after the thaw.

  16. Maple Sap Uptake, Exudation, and Pressure Changes Correlated with Freezing Exotherms and Thawing Endotherms 1

    PubMed Central

    Tyree, Melvin T.

    1983-01-01

    Sap flow rates and sap pressure changes were measured in dormant sugar maple trees (Acer saccharum Marsh.). In the forest, sap flow rates and pressure changes were measured from tap holes drilled into tree trunks in mature trees and sap flow rates were measured from the base of excised branches. Excised branches were also brought into the laboratory where air temperature could be carefully controlled in a refrigerated box and sap flow rates and sap pressures were measured from the cut base of the branches. Under both forest and laboratory conditions, sap uptake occurred as the wood temperature declined but much more rapid sap uptake correlated with the onset of the freezing exotherm. When sap pressures were measured under conditions of negligible volume displacement, the sap pressure rapidly fell to −60 to −80 kilopascals at the start of the freezing exotherm. The volume of water uptake and the rate of uptake depended on the rate of freezing. A slow freezing rate correlated with a large volume of water uptake, a fast freezing rate induced a smaller volume of water uptake. The volume of water uptake ranged from 0.02 to 0.055 grams water per gram dry weight of sapwood. The volume of water exuded after thawing was usually less than the volume of uptake so that after several freezing and thawing cycles the sapwood water content increased from 0.7 to 0.8 grams water per gram dry weight. These results are discussed in terms of a physical model of the mechanism of maple sap uptake and exudation first proposed by P. E. R. O'Malley. The proposed mechanism of sap uptake is by vapor distillation in air filled wood fiber lumina during the freezing of minor branches. Gravity and pressurized air bubbles (compressed during freezing) cause sap flow from the canopy down the tree after the thaw. PMID:16663208

  17. Variability of 4D flow parameters when subjected to changes in MRI acquisition parameters using a realistic thoracic aortic phantom.

    PubMed

    Montalba, Cristian; Urbina, Jesus; Sotelo, Julio; Andia, Marcelo E; Tejos, Cristian; Irarrazaval, Pablo; Hurtado, Daniel E; Valverde, Israel; Uribe, Sergio

    2018-04-01

    To assess the variability of peak flow, mean velocity, stroke volume, and wall shear stress measurements derived from 3D cine phase contrast (4D flow) sequences under different conditions of spatial and temporal resolutions. We performed controlled experiments using a thoracic aortic phantom. The phantom was connected to a pulsatile flow pump, which simulated nine physiological conditions. For each condition, 4D flow data were acquired with different spatial and temporal resolutions. The 2D cine phase contrast and 4D flow data with the highest available spatio-temporal resolution were considered as a reference for comparison purposes. When comparing 4D flow acquisitions (spatial and temporal resolution of 2.0 × 2.0 × 2.0 mm 3 and 40 ms, respectively) with 2D phase-contrast flow acquisitions, the underestimation of peak flow, mean velocity, and stroke volume were 10.5, 10 and 5%, respectively. However, the calculated wall shear stress showed an underestimation larger than 70% for the former acquisition, with respect to 4D flow, with spatial and temporal resolution of 1.0 × 1.0 × 1.0 mm 3 and 20 ms, respectively. Peak flow, mean velocity, and stroke volume from 4D flow data are more sensitive to changes of temporal than spatial resolution, as opposed to wall shear stress, which is more sensitive to changes in spatial resolution. Magn Reson Med 79:1882-1892, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  18. Recent numerical and algorithmic advances within the volume tracking framework for modeling interfacial flows

    DOE PAGES

    François, Marianne M.

    2015-05-28

    A review of recent advances made in numerical methods and algorithms within the volume tracking framework is presented. The volume tracking method, also known as the volume-of-fluid method has become an established numerical approach to model and simulate interfacial flows. Its advantage is its strict mass conservation. However, because the interface is not explicitly tracked but captured via the material volume fraction on a fixed mesh, accurate estimation of the interface position, its geometric properties and modeling of interfacial physics in the volume tracking framework remain difficult. Several improvements have been made over the last decade to address these challenges.more » In this study, the multimaterial interface reconstruction method via power diagram, curvature estimation via heights and mean values and the balanced-force algorithm for surface tension are highlighted.« less

  19. Catastrophic precipitation-triggered lahar at Casita volcano, Nicaragua: Occurrence, bulking and transformation

    USGS Publications Warehouse

    Scott, K.M.; Vallance, J.W.; Kerle, N.; Macias, J.L.; Strauch, W.; Devoli, G.

    2005-01-01

    A catastrophic lahar began on 30 October 1998, as hurricane precipitation triggered a small flank collapse of Casita volcano, a complex and probably dormant stratovolcano. The initial rockslide-debris avalanche evolved on the flank to yield a watery debris flood with a sediment concentration less than 60 per cent by volume at the base of the volcano. Within 2-5 km, however, the watery flow entrained (bulked) enough sediment to transform entirely to a debris flow. The debris flow, 6 km downstream and 1??2 km wide and 3 to 6 m deep, killed 2500 people, nearly the entire populations of the communities of El Porvenir and Rolando Rodriguez. These 'new towns' were developed in a prehistoric lahar pathway: at least three flows of similar size since 8330 14C years BP are documented by stratigraphy in the same 30-degree sector. Travel time between perception of the flow and destruction of the towns was only 2??5-3??0 minutes. The evolution of the flow wave occurred with hydraulic continuity and without pause or any extraordinary addition of water. The precipitation trigger of the Casita lahar emphasizes the nee d, in volcano hazard assessments, for including the potential for non-eruption-related collapse lahars with the more predictable potential of their syneruption analogues. The flow behaviour emphasizes that volcano collapses can yield not only volcanic debris avalanches with restricted runouts, but also mobile lahars that enlarge by bulking as they flow. Volumes and hence inundation areas of collapse-runout lahars can increase greatly beyond their sources: the volume of the Casita lahar bulked to at least 2??6 times the contributing volume of the flank collapse and 4??2 times that of the debris flood. At least 78 per cent of the debris flow matrix (sediment < -1??0??; 2 mm) was entrained during flow. Copyright c 2004 John Wiley & Sons, Ltd.

  20. Concept for a Satellite-Based Advanced Air Traffic Management System : Volume 8. Operational Logic Flow Diagrams for a Generic Advanced Air Traffic Management system

    DOT National Transportation Integrated Search

    1974-02-01

    The volume presents a description of the services a generic Advanced Air Traffic Management System (AATMS) should provide to the useres of the system to facilitate the safe, efficient flow of traffic. It provides a definition of the functions which t...

Top