2017-05-23
expandable stent -grafts that are designed to expand within a vessel to cover an injury or open a blockage. Methods: 3 Yorkshire cross swine were...expandable PTFE stent graft was deployed into the vessel in an open direct fashion. The swine were awoken and allowed to ambulate. At 72 hours, conduit...hours, all stents were patent on venography. Conclusion: Direct site endovascular repair of venous injuries utilizing expandable PTFE stent grafts is a
The biodurability of covering materials for metallic stents in a bile flow phantom.
Bang, Byoung Wook; Jeong, Seok; Lee, Don Haeng; Lee, Jung Il; Lee, Se Chul; Kang, Sung-Gwon
2012-04-01
Covered biliary metal stents have been introduced for the purpose of overcoming tumor ingrowth and treatment of benign biliary stricture. The aim of this study was to evaluate the biodurability of three commercially available biliary metal stent covering materials [e-PTFE (expanded polytetrafluoroethylene), silicone, and polyurethane] in a bile flow phantom. By operation of a peristaltic pump, human bile was circulated continuously in an experimental perfusion system containing covered metal stents. Each stent was removed, respectively, 1, 2, 4, and 6 months after bile exposure. We performed a gross inspection of the covered stents. The covering membrane was detached from the stent and observed by scanning electron microscopy (SEM). Finally, we measured tensile and tear strength of the membranes. Bile-staining of the membrane showed gradual progression after bile exposure; however, progress was the fastest in e-PTFE. SEM examination showed that the polyurethane surface was smooth, and the silicone surface was relatively smooth. However, e-PTFE had a rough and uneven surface. After bile exposure, there were no significant changes in polyurethane and silicone; however, biofilms and microcracks were observed in e-PTFE. In contrast to a gradual decrease of tensile/tear strength of polyurethane and silicone, those of e-PTFE showed a rapid reduction despite of the strongest baseline tensile and tear strength. e-PTFE tended to form biofilms more frequently than polyurethane and silicone during bile exposure. e-PTFE seemed to be less durable than silicone and polyurethane, however, as clinically applicable material because of strong absolute tensile/tear strengths.
Treatment of Malignant Biliary Obstruction with a PTFE-Covered Self-Expandable Nitinol Stent
Kwak, Hyo-Sung; Jin, Gong-Yong; Lee, Seung-Ok; Chung, Gyung-Ho
2007-01-01
Objective We wanted to determine the technical and clinical efficacy of using a PTFE-covered self-expandable nitinol stent for the palliative treatment of malignant biliary obstruction. Materials and Methods Thirty-seven patients with common bile duct strictures caused by malignant disease were treated by placing a total of 37 nitinol PTFE stents. These stents were covered with PTFE with the exception of the last 5 mm at each end; the stent had an unconstrained diameter of 10 mm and a total length of 50-80 mm. The patient survival rate and stent patency rate were calculated by performing Kaplan-Meier survival analysis. The bilirubin, serum amylase and lipase levels before and after stent placement were measured and then compared using a Wilcoxon signed-rank test. The average follow-up duration was 27.9 weeks (range: 2-81 weeks). Results Placement was successful in all cases. Seventy-six percent of the patients (28/37) experienced adequate palliative drainage for the remainder of their lives. There were no immediate complications. Three patients demonstrated stent sludge occlusion that required PTBD (percutaneous transhepatic biliary drainage) irrigation. Two patients experienced delayed stent migration with stone formation at 7 and 27 weeks of follow-up, respectively. Stent insertion resulted in acute elevations of the amylase and lipase levels one day after stent insertion in 11 patients in spite of performing endoscopic sphincterotomy (4/6). The bilirubin levels were significantly reduced one week after stent insertion (p < 0.01). The 30-day mortality rate was 8% (3/37), and the survival rates were 49% and 27% at 20 and 50 weeks, respectively. The primary stent patency rates were 85%, and 78% at 20 and 50 weeks, respectively. Conclusion The PTFE-covered self-expandable nitinol stent is safe to use with acceptable complication rates. This study is similar to the previous studies with regard to comparing the patency rates and survival rates. PMID:17923784
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mermuys, Koen; Maleux, Geert, E-mail: geert.maleux@uzleuven.be; Heye, Sam
2008-07-15
Four children, three boys and one girl, with a median age of 9 years 8 months, underwent transjugular intrahepatic portosystemic shunt creation with an expanded polytetrafluoroethylene (e-PTFE)-covered nitinol stent. The stent-graft was successfully placed in all four patients without any complication. Clinical and biochemical improvement was noted in all four patients during follow-up. Radiological follow-up with use of duplex ultrasound showed a recurrent stenosis of the shunt 180 days after stent-graft implantation in one patient. This was treated with placement of an additional stent-graft, re-expanding completely the recurrent stenosis. In the other three patients, the stent-graft remained fully patent untilmore » the end of the study or until orthotopic liver transplantation. These preliminary results suggest that use of the Viatorr ePTFE-covered stent-graft in children is safe and feasible, with potentially the same high patency rate and improved clinical outcome as reported in adult patients.« less
Bronchobiliary Fistula Treated by Self-expanding ePTFE-Covered Nitinol Stent-Graft
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gandini, Roberto; Konda, Daniel; Tisone, Giuseppe
A 71-year-old man, who had undergone right hepatectomy extended to the caudate lobe with terminolateral Roux-en-Y left hepatojejunostomy for a Klatskin tumor, developed bilioptysis 3 weeks postoperatively due to bronchobiliary fistula. Percutaneous transhepatic cholangiography revealed a non-dilated biliary system with contrast medium extravasation to the right subphrenic space through a resected anomalous right posterior segmental duct. After initial unsuccessful internal-external biliary drainage, the fistula was sealed with a VIATORR covered self-expanding nitinol stent-graft placed with its distal uncovered region in the hepatojejunal anastomosis and the proximal ePTFE-lined region in the left hepatic duct. A 10-month follow-up revealed no recurrence ofmore » bilioptysis and confirmed the complete exclusion of the bronchobiliary fistula.« less
Covered Stent Grafts for Acquired Arterial Venous Fistulas: A Case Series.
Sarac, Timur P; Vargas, Lina; Kashyap, Vikram; Cardella, Jonathan; Chaar, Cassius Ochoa
2018-01-01
Stent grafts have become the preferred method for treating abdominal aortic aneurysms (AAAs) but also have utility in treating other vasculopathies. In 2005, peripheral stent grafts were approved for treating superficial femoral artery occlusive disease. This report describes our experience using covered stent grafts to treat acquired arterial venous fistulae (aAVF). We reviewed the records of patients treated for aAVF with covered stent grafts. Eleven patients had 12 limbs treated with a stent graft. The data collected included presenting symptoms, mechanism of injury, vessel location, stent graft used for therapy, and patency. Eleven patients underwent successful treatment of 12 aAVF with a peripheral stent grafts. The average age was 55.6 (18-87), and there were 4 women and 7 men. The mechanisms of injuries were heart catheterization in 5 patients, penetrating trauma in 3 patients, and orthopedic injury in 3 patients. Five of the patients had concurrent pseudoaneurysms. Self-expanding expanded polytetrafluoroethelene (ePTFE) stent grafts were used in 8 patients, and balloon-expandable ePTFE stent grafts were used in 3 patients. Primary patency at 2 years is 100%, with all patients having significant relief of symptoms. Peripheral stent grafts are a useful tool for treating aAVF, with excellent patency. They provide a valuable minimally invasive approach to this disease. Copyright © 2017 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krokidis, Miltiadis, E-mail: mkrokidis@hotmail.com; Fanelli, Fabrizio; Orgera, Gianluigi
The purpose of this study was to compare the clinical effectiveness of expanded polytetrafluoroethylene/fluorinated-ethylene-propylene (ePTFE/FEP)-covered stents with that of uncovered nitinol stents for the palliation of malignant jaundice caused by inoperable pancreatic head cancer. Eighty patients were enrolled in a prospective randomized study. Bare nitinol stents were used in half of the patients, and ePTFE/FEP-covered stents were used in the remaining patients. Patency, survival, complications, and mean cost were calculated in both groups. Mean patency was 166.0 {+-} 13.11 days for the bare-stent group and 234.0 {+-} 20.87 days for the covered-stent group (p = 0.007). Primary patency rates atmore » 3, 6, and 12 months were 77.5, 69.8, and 69.8% for the bare-stent group and 97.5, 92.2, and 87.6% for the covered-stent group, respectively. Mean secondary patency was 123.7 {+-} 22.5 days for the bare-stent group and 130.3 {+-} 21.4 days for the covered-stent group. Tumour ingrowth occurred exclusively in the bare-stent group in 27.5% of cases (p = 0.002). Median survival was 203.2 {+-} 11.8 days for the bare-stent group and 247.0 {+-} 20 days for the covered-stent group (p = 0.06). Complications and mean cost were similar in both groups. Regarding primary patency and ingrowth rate, ePTFE/FEP-covered stents have shown to be significantly superior to bare nitinol stents for the palliation of malignant jaundice caused by inoperable pancreatic head cancer and pose comparable cost and complications. Use of a covered stent does not significantly influence overall survival rate; nevertheless, the covered endoprosthesis seems to offer result in fewer reinterventions and better quality of patient life.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maleux, Geert; Pirenne, Jacques; Vaninbroukx, Johan
Our purpose was to assess the feasibility of orthotopic liver transplantation (OLT) in patients priorly having undergone transjugular intrahepatic portosystemic shunt (TIPS) with an expanded tetrafluoroethylene (e-PTFE)-covered endoprosthesis. In 48 patients an e- PTFE-covered endoprosthesis was inserted to treat severe complications of portal hypertension. In 36 patients the endoprosthesis was inserted during TIPS creation (de novo TIPS); in the other 12 patients the endoprosthesis was placed to repermeabilize the previously created, but occluded bare stent (revision TIPS). Eight of them (5 de novo and 3 revision cases) later underwent an OLT. The hospital records of these patients were reviewed frommore » initial admission, through TIPS, the pre-OLT period, and OLT to current postoperative status. Five de novo and 3 revision cases underwent OLT 4-279 days (mean delay: 80.8 days) after TIPS procedure. All OLT's were performed under veno-venous bypass surgery. De visu surgical inspection confirmed correct positioning of the fully patent stent graft, starting in the portal vein and ending at the junction of the hepatic vein to the inferior caval vein. No surgical difficulty was observed during proximal or distal clamping or during resection of the diseased liver. Correctly positioned e-PTFE-covered nitinol endoprostheses do not interfere with a later OLT and may not be considered as a contraindication in patients who need a TIPS as a bridge to OLT.« less
Immunolocalization of markers for bone formation during guided bone regeneration in osteopenic rats
TERA, Tábata de Mello; NASCIMENTO, Rodrigo Dias; do PRADO, Renata Falchete; SANTAMARIA, Mauro Pedrine; JARDINI, Maria Aparecida Neves
2014-01-01
Objective The aim of this paper was to evaluate the repair of onlay autogenous bone grafts covered or not covered by an expanded polytetrafluoroethylene (e-PTFE) membrane using immunohistochemistry in rats with induced estrogen deficiency. Material and Methods Eighty female rats were randomly divided into two groups: ovariectomized (OVX) and with a simulation of the surgical procedure (SHAM). Each of these groups was again divided into groups with either placement of an autogenous bone graft alone (BG) or an autogenous bone graft associated with an e-PTFE membrane (BGM). Animals were euthanized on days 0, 7, 21, 45, and 60. The specimens were subjected to immunohistochemistry for bone sialoprotein (BSP), osteonectin (ONC), and osteocalcin (OCC). Results All groups (OVX+BG, OVX+BMG, SHAM+BG, and SHAM+BMG) showed greater bone formation, observed between 7 and 21 days, when BSP and ONC staining were more intense. At the 45-day, the bone graft showed direct bonding to the recipient bed in all specimens. The ONC and OCC showed more expressed in granulation tissue, in the membrane groups, independently of estrogen deficiency. Conclusions The expression of bone forming markers was not negatively influenced by estrogen deficiency. However, the markers could be influenced by the presence of the e-PTFE membrane. PMID:25591022
In Vitro Hemocompatibility of Thin Film Nitinol In Stenotic Flow Conditions
Kealey, C.P.; Whelan, S.A.; Chun, Y.J.; Soojung, C.H.; Tulloch, A.W.; Mohanchandra, K.P.; DiCarlo, D; Levi, D.S.; Carman, G.P.; Rigberg, D.A.
2010-01-01
Because of its low profile and biologically inert behavior, thin film nitinol (TFN) is ideally suited for use in construction of endovascular devices. We have developed a surface treatment for TFN designed to minimize platelet adhesion by creating a super-hydrophilic surface. The hemocompatibility of expanded polytetrafluorethylene (ePTFE), untreated thin film nitinol (UTFN), and a surface treated superhydrophilic thin film nitinol (STFN) was compared using an in vitro circulation model with whole blood under flow conditions simulating a moderate arterial stenosis. Scanning electron microscopy analysis showed increased thrombus on ePTFE as compared to UTFN or STFN. Total blood product deposition was 6.3 ± 0.8 mg/cm2 for ePTFE, 4.5 ± 2.3 mg/cm2 for UTFN, and 2.9 ± 0.4 mg/cm2 for STFN (n = 12, p < 0.01). ELISA assay for fibrin showed 326 ± 42 µg/cm2 for ePTFE, 45.6 ± 7.4 µg/cm2 for UTFN, and 194 ± 25 µg/cm2 for STFN (n = 12, p < 0.01). Platelet deposition measured by fluorescent intensity was 79,000 ± 20000 AU/mm2 for ePTFE, 810 ± 190 AU/mm2 for UTFN, and 1600 ± 25 AU/mm2 for STFN (n = 10, p < 0.01). Mass spectrometry demonstrated a larger number of proteins on ePTFE as compared to either thin film. UTFN and STFN appear to attract significantly less thrombus than ePTFE. Given TFN's low profile and our previously demonstrated ability to place TFN covered stents in vivo, it is an excellent candidate for use in next-generation endovascular stents grafts. PMID:20810163
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blue, Robert C., E-mail: Robert.c.blue@gmail.com; Lo, Grace C.; Kim, Edward
PurposeA complication of transjugular intrahepatic portosystemic shunts (TIPS) placement is refractory portosystemic encephalopathy (PSE) often requiring TIPS reduction. We report the results of a “sheath control technique” utilizing constraining sheaths during deployment of polytetrafluoroethylene (PTFE)-covered balloon-expandable stents, minimizing stent migration, and providing additional procedural control.MethodsTIPS reduction was performed in 10 consecutive patients for PSE using Atrium iCast covered stents (Atrium Maquet Getinge Group, Germany). Within the indwelling TIPS stent, a 9 mm × 59 mm iCast stent was deployed with 2 cm exposed from the sheath’s distal end and the majority of the stent within the sheath to create the distal hourglass shape. During balloonmore » retraction, the stent was buttressed by the sheath. The proximal portion of the stent was angioplastied to complete the hourglass configuration, and the central portion of the stent was dilated to 5 mm. Demographics, pre- and post-procedure laboratory values, and outcomes were recorded.ResultsTen patients underwent TIPS reduction with 100 % technical success. There was no stent migration during stent deployment. All patients experienced initial improvement of encephalopathy. One patient ultimately required complete TIPS occlusion for refractory PSE, and another developed TIPS occlusion 36 days post-procedure. There was no significant trend toward change in patients’ MELD scores immediately post-procedure or at 30 days (p = 0.46, p = 0.47, respectively).ConclusionTIPS reduction using Atrium iCast PTFE balloon-expandable stents using the “sheath control technique” is safe and effective, and minimizes the risk of stent migration.« less
Low-Thermal-Expansion Filled Polytetrafluoroethylene
NASA Technical Reports Server (NTRS)
Shapiro, Sanford S.
1989-01-01
PTFE made thermally compatible with aluminum without changing dielectric constant. Manufactured with fillers and pores to reduce coefficient of thermal expansion by factor of 6 to match aluminum. Material retains 2.1 dielectric constant of pure PTFE. Combines filler and micropore concepts. Particles and voids embedded in PTFE matrix function cooperatively. Particles take up compressive stress imposed by contracting PTFE, and voids take up expanding material. Increases dielectric constant, while voids reduce it.
Park, Jung Gu; Jung, Gyoo-Sik; Oh, Kyung Seung; Park, Seon-Ja
2010-08-01
We evaluated the effectiveness of a double-layered polytetrafluoroethylene (PTFE)-covered nitinol stent in the palliative treatment of malignant esophageal strictures. A double-layered PTFE-covered nitinol stent was designed to reduce the propensity to migration of conventional covered stent. The stent consists of an inner PTFE-covered stent and an outer uncovered nitinol stent tube. With fluoroscopic guidance, the stent was placed in 32 consecutive patients with malignant esophageal strictures. During the follow-up period, the technical and clinical success rates, complications, and cumulative patient survival and stent patency were evaluated. Stent placement was technically successful in all patients, and no procedural complications occurred. After stent placement, the symptoms of 30 patients (94%) showed improvement. During the mean follow-up of 103 days (range, 9-348 days), 11 (34%) of 32 patients developed recurrent symptoms due to tumor overgrowth in five patients (16%), tumor ingrowth owing to detachment of the covering material (PTFE) apart from the stent wire in 3 (9%), mucosal hyperplasia in 2 (6%), and stent migration in 1 (3%). Ten of these 11 patients were treated by means of placing a second covered stent. Thirty patients died, 29 as a result of disease progression and 1 from aspiration pneumonia. The median survival period was 92 days. The median period of primary stent patency was 190 days. The double-layered PTFE-covered nitinol stent seems to be effective for the palliative treatment of malignant esophageal strictures. We believe that the double-layer configuration of this stent can contribute to decreasing the stent's migration rate.
Novel Remanufacturing Process of Recycled Polytetrafluoroethylene(PTFE)/GF Laminate
NASA Astrophysics Data System (ADS)
Xi, Z.; Ghita, O. R.; Johnston, P.; Evans, K. E.
2011-01-01
Currently, the PTFE/GF laminate and PTFE PCB manufacturers are under considerable pressure to address the recycling issues due to Waste Electrical and Electronic Equipment (WEEE) Directive, shortage of landfill capacity and cost of disposal. This study is proposing a novel manufacture method for reuse of the mechanical ground PTFE/Glass fibre (GF) laminate and production of the first reconstitute PTFE/GF laminate. The reconstitute PTFE/GF laminate proposed here consists of a layer of recycled sub-sheet, additional layers of PTFE and PTFE coated glass cloth, also covered by copper foils. The reconstitute PTFE/GF laminate showed good dielectric properties. Therefore, there is potential to use the mechanical ground PTFE/GF laminate powder to produce reconstitute PTFE/GF laminate, for use in high frequencies PCB applications.
Hsu, Shih-Chao; Thorat, Ashok; Yang, Horng-Ren; Poon, Kin-Shing; Li, Ping-Chun; Yeh, Chun-Chieh; Chen, Te-Hung; Jeng, Long-Bin
2017-07-06
BACKGROUND Our recent studies have highlighted the importance and safety of backtable venoplasty for middle hepatic vein (MHV) and inferior right hepatic veins (IRHV) reconstruction using expanded polytetrafluoroethylene (ePTFE) vascular grafts. In this study, we aim to analyze the complications associated with ePTFE graft use and discuss the management of the rare, but, potentially life threatening complications directly related to ePTFE conduits. MATERIAL AND METHODS From January 2012 to October 2015 a total of 397 patients underwent living donor liver transplantation (LDLT). The ePTFE vascular grafts were used during the backtable venoplasty for outflow reconstruction in 262 of the liver allografts. Recipients who developed ePTFE-related complications were analyzed. RESULTS ePTFE-related complications developed in 1.52% (4/262) of the patients. One patient (0.38%) developed complete thrombosis with sepsis at 24 months post-transplantation and died due to multiorgan failure. Three patients (1.1%) developed graft migration into the second portion of the duodenum, without overt peritonitis. Surgical exploration and ePTFE graft removal was done in all the patients. One patient died due to overwhelming sepsis. CONCLUSIONS ePTFE graft migration into the duodenum causing perforation is a new set of complications that has been recently described in LDLT and can be treated effectively by surgical removal of the infected vascular graft and duodenal perforation closure. Despite of such complications, in our experience, ePTFE use in LDLT continues to have wide safety margin, with a complication rate of only 1.52%.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, Jung Gu; Jung, Gyoo-Sik, E-mail: gsjung@medimail.co.kr; Oh, Kyung Seung
We evaluated the effectiveness of a double-layered polytetrafluoroethylene (PTFE)-covered nitinol stent in the palliative treatment of malignant esophageal strictures. A double-layered PTFE-covered nitinol stent was designed to reduce the propensity to migration of conventional covered stent. The stent consists of an inner PTFE-covered stent and an outer uncovered nitinol stent tube. With fluoroscopic guidance, the stent was placed in 32 consecutive patients with malignant esophageal strictures. During the follow-up period, the technical and clinical success rates, complications, and cumulative patient survival and stent patency were evaluated. Stent placement was technically successful in all patients, and no procedural complications occurred. Aftermore » stent placement, the symptoms of 30 patients (94%) showed improvement. During the mean follow-up of 103 days (range, 9-348 days), 11 (34%) of 32 patients developed recurrent symptoms due to tumor overgrowth in five patients (16%), tumor ingrowth owing to detachment of the covering material (PTFE) apart from the stent wire in 3 (9%), mucosal hyperplasia in 2 (6%), and stent migration in 1 (3%). Ten of these 11 patients were treated by means of placing a second covered stent. Thirty patients died, 29 as a result of disease progression and 1 from aspiration pneumonia. The median survival period was 92 days. The median period of primary stent patency was 190 days. The double-layered PTFE-covered nitinol stent seems to be effective for the palliative treatment of malignant esophageal strictures. We believe that the double-layer configuration of this stent can contribute to decreasing the stent's migration rate.« less
Expanded polytetrafluoroethylene graft fistula for chronic hemodialysis.
Tellis, V A; Kohlberg, W I; Bhat, D J; Driscoll, B; Veith, F J
1979-01-01
In a retrospective study of 66 PTFE arteriovenous fistulae and 71 BCH arteriovenous fistulae for dialysis access, PTFE had a higher patency rate than BCH at 12 months (62.4 versus 32.5%). PTFE was easier to work with and easier to handle in the face of infection. The lateral upper arm approach to placement of the PTFE graft is desirable in patients who have had multiple previous access procedures because this area is usually free from scarring, is distant from neurovascular structures, and provides a greater length of graft for needle punctures.
Na, Han Kyu; Song, Ho-Young; Kim, Jin Hyoung; Park, Jung-Hoon; Kang, Min Kyoung; Lee, Jongjin; Oh, Se Jin
2013-03-01
To evaluate the clinical efficacy and safety of self-expandable metallic stent (SEMS) placement for malignant oesophageal strictures and their relationship with stent designs. Seven generations of SEMS were used to treat 645 consecutive patients with oesophageal strictures. Logistic regression models were constructed to identify predictive factors associated with complications. Stent placement was technically successful in 641 of 645 patients (99.4%). The clinical success rate was 95.5%. There were 260 (40.3%) complications after stent placement. Due to complications, 68 stents were removed; 66 of 68 stents (97.1%) were removed successfully. Stainless steel (SS) stents (odds ratio [OR] 4.18; 95% confidence interval [CI] 2.10, 8.32) and radiation therapy (RT) before stent placement (OR 4.23; CI 2.02, 8.83) were significantly associated with severe pain. Flared ends (OR 9.63; CI 3.38, 27.43), stricture length <6 cm (OR 2.01; CI 1.13, 3.60), and a stent diameter <18 mm (OR 3.00; CI 1.32, 6.84) were predictive factors of stent migration. Polyurethane membranes were associated with more frequent tumour ingrowth than polytetrafluoroethylene (PTFE) membranes (P = 0.002). Despite the relatively high complication rate, retrievable self-expandable PTFE-covered nitinol stents equipped with a head and a tail appeared to be an effective treatment for malignant oesophageal strictures.
Expanded polytetrafluoroethylene graft fistula for chronic hemodialysis.
Tellis, V A; Kohlberg, W I; Bhat, D J; Driscoll, B; Veith, F J
1979-01-01
In a retrospective study of 66 PTFE arteriovenous fistulae and 71 BCH arteriovenous fistulae for dialysis access, PTFE had a higher patency rate than BCH at 12 months (62.4 versus 32.5%). PTFE was easier to work with and easier to handle in the face of infection. The lateral upper arm approach to placement of the PTFE graft is desirable in patients who have had multiple previous access procedures because this area is usually free from scarring, is distant from neurovascular structures, and provides a greater length of graft for needle punctures. Images Fig. 3. PMID:758853
Anatomic changes of target vessels after fenestrated and branched aortic aneurysm repair.
Kalder, J; Keschenau, P; Tamm, M; Jalaie, H; Jacobs, M J; Greiner, A
2014-04-01
Objective of this study was to evaluate the anatomic changes of the stented target vessels after endovascular repair of complex aortic aneurysms. Between July 2011 and December 2013, 53 aortic aneurysms were treated in our department with fenestrated and branched stent-graft devices. Forty-two of these patients were pre- and postoperatively scanned with a high resolution computer tomography (CT) (Cook Zenith® fenestrated or branched, Australia Pty. Ltd., Brisbane, Australia: N.=19; AnacondaTM fenestrated, Vascutek, Glasgow, Scotland, UK: N.=23). The other 11 out of the 53 patients did not receive a CT scan, because of a pre-existing renal failure. In the CT scans we retrospectively evaluated the anatomic vessel deviation at the origin of the target vessel and the vessel shift distal to the stent. For the first measurement the CT scans were loaded into OsiriX MD®, and the pre- and postoperative angles of the target vessels were measured and subtracted. For matching, the CT-scans were normalized at vertebral body lumbar 2. The second measured angle was the maximal measured angle distal to the target vessel stent-graft. Altogether, 113 target vessels were stented (celiac trunk [CT] 15, superior mesenteric arteries [SMA] 26, renal arteries [RA] 72), with 97 balloon-expandable PTFE stents: 90 Atrium V12 (Maquet Getinge group, Hudson, NH, USA), 7 BeGrafts (Bentley InnoMed, Hechingen, Germany) and 16 self-expandable fluency PTFE stents (Bard, Karlsruhe, Germany). The mean anatomic deviation at the target vessel origin was 28±17.3 and the mean vessel shift distal to the stent was 36.3±18.8. There were no significant differences between the main device and the target vessel stent types. Fenestrated and branched stent-graft solutions for aortic aneurysm repair induce changes of the target vessel anatomy. We did not observe significant differences between the several devices.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gandini, Roberto; Pipitone, Vincenzo; Konda, Daniel, E-mail: danielkonda@yahoo.com
2005-01-15
A 68-year-old woman presenting with gastrointestinal bleeding (hematocrit 19.3%) and in a critical clinical condition (American Society of Anesthesiologists grade 4) from a giant superior mesenteric artery pseudoaneurysm (196.0 x 131.4 mm) underwent emergency endovascular treatment. The arterial tear supplying the pseudoaneurysm was excluded using a 5.0 mm diameter and 31 mm long monorail expanded polytetrafluoroethylene (ePTFE)-covered self-expanding nitinol stent. Within 6 days of the procedure, a gradual increase in hemoglobin levels and a prompt improvement in the clinical condition were observed. Multislice CT angiograms performed immediately, 5 days, 30 days and 3 months after the procedure confirmed the completemore » exclusion of the pseudoaneurysm.« less
Joo, Yeon Hee; Jang, Yong Ju
2016-09-01
Dorsal augmentation material includes alloplastic implants and autologous tissues. However, there has been no comparison to date of dorsal augmentation using different materials performed by the same surgeon. To compare the aesthetic outcomes and complications of dorsal augmentation using expanded polytetrafluoroethylene (ePTFE) and autologous costal cartilage (ACC) in rhinoplasty. A retrospective review of the medical records of 244 patients who underwent dorsal augmentation performed by the same surgeon at the Asan Medical Center using ePTFE or ACC from March 1, 2003, through September 31, 2015. Patient demographics and surgical procedures were analyzed. The aesthetic outcomes were scored from 1 (worst) to 4 (best) by 3 otolaryngologists. Changes in dorsal height and radix height were measured by comparing preoperative and postoperative profile views. Postoperative complications were also evaluated. A total of 244 patients who underwent augmentation rhinoplasty were reviewed in this study, including 141 men (57.8%) and 103 women (42.2%). The ePTFE group included 176 patients, and the ACC group comprised 68 patients. In the ePTFE and ACC groups, 96 patients (54.5%) and 45 patients (66.2%) were male, respectively. The patient ages ranged from 11 to 69 years, with a mean (SD) age of 30.3 (11.49) years in the ePTFE group and 36.04 (12.65) years in the ACC group. The mean (SD) aesthetic outcome scores were comparable between the 2 groups: 2.99 (0.05) in the ePTFE group and 2.99 (0.06) in the ACC group (P = .93). The change of dorsal (2.64% in ePTFE group and 5.82% in ACC group) and radix (3.62% in ePTFE group and 3.77% in ACC group) heights were significantly increased after augmentation in both groups (P < .001) even though the dorsal height of the ACC group after augmentation showed a significantly greater increase compared to the ePTFE group (P < .001). However, the complication rate was significantly higher in the ACC group: 4.0% in ePTFE group and 11.8% in ACC group (P = .02). Dorsal augmentation with ACC produces similar aesthetic outcomes but a higher complication rate than dorsal augmentation with ePTFE. This higher complication rate may justify the use of ePTFE implants for dorsal augmentation in Asian patients undergoing rhinoplasty. 3.
ERIC Educational Resources Information Center
Kim, Young-Suk Grace
2015-01-01
The primary goal was to expand our understanding of text-reading fluency (efficiency or automaticity): how its relation to other constructs (e.g., word reading fluency, reading comprehension) changes over time and how it is different from word-reading fluency and reading comprehension. The study examined (a) developmentally changing relations…
ERIC Educational Resources Information Center
Kim, Young-Suk Grace
2015-01-01
The primary goal was to expand our understanding of text-reading fluency (efficiency or automaticity): how its relation to other constructs (e.g., word-reading fluency, reading comprehension) changes over time and how it is different from word-reading fluency and reading comprehension. The study examined (a) developmentally changing relations…
Carbon protrusions on PTFE surface prepared by ion irradiation and chemical defluorination
NASA Astrophysics Data System (ADS)
Kobayashi, T.; Iwaki, M.
2006-01-01
A surface of PTFE was covered with small protrusions by ion-beam irradiation. In this study, we converted PTFE protrusions into carbon protrusions by a defluorination (carbonization) process using sodium vapor. The morphology, composition and structure were analyzed by SEM-EDX, Raman spectroscopy and TEM. The irradiated PTFE sheets were packed in evacuated glass tubes with a sodium block and kept at 473 K for 2-48 h. The samples were then rinsed in HCl and distilled water to remove NaF precipitates. The EDX measurement showed that the NaF precipitates were completely removed by washing, and the percentage of carbon atoms was controlled from 60% to 99% by the treatment. Raman spectra showed that graphite structures grow during the defluorination process. TEM micrographs showed that the protrusions have a bubble structure and are covered with a thin wall. The carbonized protrusions were conductive and grew perpendicular to the substrate.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fanelli, Fabrizio, E-mail: fabrizio.fanelli@uniroma1.it; Bezzi, Mario; Bruni, Antonio
2011-02-15
We assessed, in a prospective study, the efficacy of multidetector spiral computed tomography (MDCT) in the evaluation of transjugular intrahepatic portosystemic shunt (TIPS) patency in patients treated with the Viatorr (Gore, Flagstaff, AZ) expanded-polytetrafluoroethylene (e-PTFE)-covered stent-graft. Eighty patients who underwent TIPS procedure using the Viatorr self-expanding e-PTFE stent-graft were evaluated at follow-up of 1, 3, 6, and 12 months with clinical and laboratory tests as well as ultrasound-color Doppler (USCD) imaging. In case of varices, upper gastrointestinal endoscopy was also performed. In addition, the shunt was evaluated using MDCT at 6 and 12 months. In all cases of abnormal findingsmore » and discrepancy between MDCT and USCD, invasive control venography was performed. MDCT images were acquired before and after injection of intravenous contrast media on the axial plane and after three-dimensional reconstruction using different algorithms. MDCT was successfully performed in all patients. No artefacts correlated to the Viatorr stent-graft were observed. A missing correlation between UCSD and MDCT was noticed in 20 of 80 (25%) patients. Invasive control venography confirmed shunt patency in 16 (80%) cases and shunt malfunction in 4 (20%) cases. According to these data, MDCT sensitivity was 95.2%; specificity was 96.6%; and positive (PPV) and negative predictive values (NPV) were 90.9 and 98.2%, respectively. USCD sensitivity was 90%; specificity was 75%; and PPV and NPV were 54.5 and 95.7%, respectively. A high correlation (K value = 0.85) between MDCT and invasive control venography was observed. On the basis of these results, MDCT shows superior sensitivity and specificity compared with USCD in those patients in whom TIPS was performed with the Viatorr stent-graft. MDCT can be considered a valid tool in the follow-up of these patients.« less
NASA Astrophysics Data System (ADS)
Furuta, Masakazu; Matsugaki, Aira; Nakano, Takayoshi; Hirata, Isao; Kato, Koichi; Oda, Takashi; Sato, Mamoru; Okazaki, Masayuki
2017-10-01
Recently, Co-60 gamma-ray irradiation has become markedly popular for the sterilization of biomedical materials, including expanded PTFE. However, its effect on the properties of PTFE has not been thoroughly examined. In this study, changes in the properties of PTFE before and after irradiation were analyzed physicochemically and discussed crystallographically. The tensile breaking strengths of PTFE decreased markedly on irradiation at 1 kGy, and were maintained at almost one fourth of the original value (44.3±2.5 N/mm2) ranging from 5 to 100 kGy. XPS analysis indicated that the atomic concentrations of carbon (C) and fluorine (F) of PTFE were not different among samples irradiated at various dosages. Raman spectra of PTFE showed a slight increase of the absorption peak intensity at 735 cm-1 in an irradiation dosage-dependent manner. X-ray diffraction showed that the crystal size of PTFE (56.7±1.0 nm) became smaller after radiation at 100 kGy (48.5±0.6 nm). These results are consistent with the above results of Raman analysis. It is suggested that the observed changes in the mechanical properties of PTFE may be due to nano-scale C-C bond scission by gamma ray irradiation, and not due to the formation of micro-scale cracks.
Jin, Young Ju; Kang, Sunah; Park, Pona; Choi, Dongkil; Kim, Dae Woo; Jung, Dongwook; Koh, Jaemoon; Jeon, Joohee; Lee, Myoungjin; Ham, Jiyeon; Seo, Ji-Hun; Jin, Hong-Ryul; Lee, Yan
2017-06-07
Expanded polytetrafluoroethylene (ePTFE), also known as Gore-Tex, is widely used as an implantable biomaterial in biomedical applications because of its favorable mechanical properties and biochemical inertness. However, infection and inflammation are two major complications with ePTFE implantations, because pathogenic bacteria can inhabit the microsized pores, without clearance by host immune cells, and the limited biocompatibility can induce foreign body reactions. To minimize these complications, we covalently grafted a biomembrane-mimic polymer, poly(2-methacryloyloxylethyl phosphorylcholine) (PMPC), by partial defluorination followed by UV-induced polymerization with cross-linkers on the ePTFE surface. PMPC grafting greatly reduced serum protein adsorption as well as fibroblast adhesion on the ePTFE surface. Moreover, the PMPC-grafted ePTFE surface exhibited a dramatic inhibition of the adhesion and growth of Staphylococcus aureus, a typical pathogenic bacterium in ePTFE implants, in the porous network. On the basis of an analysis of immune cells and inflammation-related factors, i.e., transforming growth factor-β (TGF-β) and myeloperoxidase (MPO), we confirmed that inflammation was efficiently alleviated in tissues around PMPC-grafted ePTFE plates implanted in the backs of rats. Covalent PMPC may be an effective strategy for promoting anti-inflammatory and antibacterial functions in ePTFE implants and to reduce side effects in biomedical applications of ePTFE.
Furukawa, K S; Ushida, T; Sugano, H; Tamaki, T; Ohshima, N; Tateishi, T
2000-01-01
We visualized in real-time platelets adhering to the surface of three representative biomaterials, by using an apparatus consisting of a modified cone and plate rheometer combined with an upright epifluorescence microscope under two shear flows (0.1 and 5.0 dyne/cm2). The materials were expanded polytetrafluoroethylene (ePTFE), silicone sheet, and a monolayer of bovine endothelial cells (ECs) formed on glass, all of which are opaque materials used for artificial blood vessels and medical devices. According to quantitative analysis, the monolayer of ECs formed on glass had better blood compatibility than did either the ePTFE or the silicone sheet under shear flow conditions. Under a shear flow condition of 0.1 dyne/cm2, platelet adhesion was silicone sheet > ePTFE. In contrast, under a shear flow condition of 5.0 dyne/cm2, ePTFE > silicone sheet. These results indicate that the intensity of shear stress could modify the order of hemocompatibility of the materials. Therefore, direct observation of platelet adhesion under shear flow conditions is indispensable for testing and screening biomaterials and for providing a precise quantitative evaluation of platelet adhesion.
Hyaluronic acid enhancement of expanded polytetrafluoroethylene for small diameter vascular grafts
NASA Astrophysics Data System (ADS)
Lewis, Nicole R.
Cardiovascular disease is the leading cause of mortality and morbidity in the United States and other developed countries. In the United States alone, 8 million people are diagnosed with peripheral arterial disease per year and over 250,000 patients have coronary bypass surgery each year. Autologous blood vessels are the standard graft used in small diameter (<6mm) arterial bypass procedures. Synthetic small diameter grafts have had limited success. While polyethylene (Dacron) and expanded polytetrafluoroethylene (ePTFE) are the most commonly used small diameter synthetic vascular graft materials, there are significant limitations that make these materials unfavorable for use in the low blood flow conditions of the small diameter arteries. Specifically, Dacron and ePTFE grafts display failure due to early thrombosis or late intimal hyperplasia. With the shortage of tissue donors and the limited supply of autologous blood vessels available, there is a need for a small diameter synthetic vascular graft alternative. The aim of this research is to create and characterize ePTFE grafts prepared with hyaluronic acid (HA), evaluate thrombogenic potential of ePTFE-HA grafts, and evaluate graft mechanical properties and coating durability. The results in this work indicate the successful production of ePTFE-HA materials using a solvent infiltration technique. Surface interactions with blood show increased platelet adhesion on HA-modified surfaces, though evidence may suggest less platelet activation and erythrocyte lysis. Significant changes in mechanical properties of HA-modified ePTFE materials were observed. Further investigation into solvent selection, uniformity of HA, endothelialization, and dynamic flow testing would be beneficial in the evaluation of these materials for use in small diameter vascular graft bypass procedures.
Nitinol Esophageal Stents: New Designs and Clinical Indications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Strecker, Ernst-Peter; Boos, Irene; Vetter, Sylvia
1996-11-15
Purpose: To evaluate the clinical use of covered and noncovered, knitted nitinol stents in patients presenting new stent indications. Methods: Self-expandable, knitted nitinol stents were implanted in four patients for treatment of dysphagia. In two patients who had malignant strictures and had esophago-respiratory fistulae and in one patient with an esophagocutaneous fistula, polytetrafluoroethylene (PTFE)-covered stents were implanted. One patient received a noncovered stent, but a retrograde approach through a percutaneous endoscopic gastrostomy (PEG) fistula had to be chosen for recanalization of an esophageal occlusion. Two patients received stents for treatment of benign strictures. Results: Recanalization of the stricture and stentmore » implantation were performed under fluoroscopic control without any procedure-related morbidity or mortality. Dysphagia improved in all patients and the esophageal fistulae could be sealed off by covered stents. During a maximum follow-up of 18 months, there was no stent migration or esophageal perforation. Complications observed were stent stenosis due to food impaction (1/4) and benign stent stenosis (2/2). Most complications could be treated by the interventional radiologist. Conclusion: Self-expandable, covered Nitinol stents provide an option for the treatment of dysphagia combined with esophageal fistulae. In combination with interventional radiology techniques, even complex strictures are accessible. For benign strictures, the value of stent treatment has not yet been proven.« less
Percutaneous biliary covered stent insertion in patients with malignant duodenobiliary obstruction.
Lee, Eunsol; Gwon, Dong Il; Ko, Gi-Young; Sung, Kyu-Bo; Yoon, Hyun-Ki; Shin, Ji Hoon; Kim, Jin Hyoung; Ko, Heung Kyu; Song, Ho-Young
2015-02-01
Although the use of polytetrafluoroethylene (PTFE)-covered biliary stents has proven to be feasible for the treatment of benign and malignant biliary disease, less is known regarding the outcomes of percutaneous placement of a covered stent in patients with malignant duodenobiliary obstruction. To investigate the technical and clinical efficacy of the percutaneous placement of a PTFE-covered biliary stent in patients with malignant duodenobiliary obstruction. From April 2007 to September 2012, the medical records of 45 consecutive patients with malignant duodenobiliary obstruction were retrospectively reviewed. All percutaneous biliary stent deployment was performed using PTFE-covered stents, whereas duodenal stent insertion was performed either fluoroscopically or endoscopically using covered or uncovered stents. Biliary stent deployment was technically successful in all patients. None of the stents migrated after deployment. Procedure-related minor complications, including self-limiting hemobilia, occurred in three (7%) patients. Successful internal drainage was achieved in 39 (87%) of the 45 patients. The median survival time after biliary stent placement was 62 days (95% confidence interval, 8-116 days), and the cumulative stent patency rates at 1, 3, 6, and 12 months were 96%, 92%, 75%, and 38%, respectively. The causes of biliary stent dysfunction included stent occlusion caused by a subsequently inserted duodenal stent (n = 7), food impaction (n = 3), and sludge incrustation (n = 1). One patient developed acute cholecystitis 131 days after biliary stent placement and underwent percutaneous transhepatic gallbladder drainage. Percutaneous insertion of a PTFE-covered stent is a safe and effective method for palliative treatment of patients with malignant duodenobiliary obstruction. If possible, subsequent biliary stent insertion is preferable in order to prevent possible biliary stent dysfunction caused by subsequent insertion of a duodenal stent. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Wood, A. J.; Cozad, M. J.; Grant, D. A.; Ostdiek, A. M.; Bachman, S. L.
2014-01-01
During its tenure in vivo, synthetic mesh materials are exposed to foreign body responses, which can alter physicochemical properties of the material. Three different synthetic meshes comprised of polypropylene, expanded polytetrafluoroethylene (ePTFE), and polyethylene terephthalate (PET) materials were explanted from a single patient providing an opportunity to compare physicochemical changes between three different mesh materials in the same host. Results from infrared spectroscopy demonstrated significant oxidation in polypropylene mesh while ePTFE and PET showed slight chemical changes that may be caused by adherent scar tissue. Differential scanning calorimetry results showed a significant decrease in the heat of enthalpy and melt temperature in the polypropylene mesh while the ePTFE and PET showed little change. The presence of giant cells and plasma cells surrounding the ePTFE and PET were indicative of an active foreign body response. Scanning electron micrographs and photo micrographs displayed tissue entrapment and distortion of all three mesh materials. PMID:23371769
DOE Office of Scientific and Technical Information (OSTI.GOV)
Makutani, Shiro; Kichikawa, Kimihiko; Uchida, Hideo
Purpose: To evaluate the efficacy of antithrombotic agents in the prevention of stenosis of polytetrafluoroethylene (PTFE)-covered stents in the venous system. Methods: Spiral Z stents covered with PTFE (PTFE-covered stents) were placed in the inferior vena cava (IVC) of 34 dogs. Nineteen dogs, used as a control group, were sacrificed at 2, 4, and 12 weeks. Fifteen dogs, previously given antithrombotic agents [cilostazol (n= 5), warfarin potassium (n= 5), cilostazol plus warfarin potassium (n= 5)] were sacrificed at 4 weeks, and then examined angiographically and histopathologically. The effect of the antithrombotic agents was compared between groups. Results: The patency ratemore » of the antithrombotic agent group was 93% (14/15), which was higher than the control group rate of 63% (12/19). The mean stenosis rate of the patent stent at both ends and at the midportion was lower at 4 weeks in the antithrombotic agent group than in the control group. In particular, the mean stenosis rate in the cilostazol plus warfarin potassium group was significantly lower than the control group (Tukey's test, p < 0.05). The mean neointimal thickness of the patent stent at both ends and at the midportion was thinner at 4 weeks in the antithrombotic agent group than in the control group. In particular, the thickness of the neointima in the cilostazol plus warfarin potassium group was significantly decreased when compared with the control group (Tukey's test p < 0.05). At 4 weeks, endothelialization in the antithrombotic agent group tended to be almost identical to that in the control group. Conclusion: The present study suggests that administration of an antithrombotic agent is an effective way of preventing the stenosis induced by a neointimal thickening of PTFE-covered stents in the venous system.« less
Son, Rak Chae; Gwon, Dong Il; Ko, Heung Kyu; Kim, Jong Woo; Ko, Gi-Young
2015-01-01
To investigate the outcomes of percutaneous unilateral metallic stent placement in patients with a malignant obstruction of the biliary hila and a contralateral portal vein steno-occlusion. Sixty patients with a malignant hilar obstruction and unilobar portal vein steno-occlusion caused by tumor invasion or preoperative portal vein embolization were enrolled in this retrospective study from October 2010 to October 2013. All patients were treated with percutaneous placement of a biliary metallic stent, including expanded polytetrafluoroethylene (ePTFE)-covered stents in 27 patients and uncovered stents in 33 patients. A total of 70 stents were successfully placed in 60 patients. Procedural-related minor complications, including self-limiting hemobilia (n = 2) and cholangitis (n = 4) occurred in six (10%) patients. Acute cholecystitis occurred in two patients. Successful internal drainage was achieved in 54 (90%) of the 60 patients. According to a Kaplan-Meier analysis, median survival time was 210 days (95% confidence interval [CI], 135-284 days), and median stent patency time was 133 days (95% CI, 94-171 days). No significant difference in stent patency was observed between covered and uncovered stents (p = 0.646). Stent dysfunction occurred in 16 (29.6%) of 54 patients after a mean of 159 days (range, 65-321 days). Unilateral placement of ePTFE-covered and uncovered stents in the hepatic lobe with a patent portal vein is a safe and effective method for palliative treatment of patients with a contralateral portal vein steno-occlusion caused by an advanced hilar malignancy or portal vein embolization. No significant difference in stent patency was detected between covered and uncovered metallic stents.
Son, Rak Chae; Ko, Heung Kyu; Kim, Jong Woo; Ko, Gi-Young
2015-01-01
Objective To investigate the outcomes of percutaneous unilateral metallic stent placement in patients with a malignant obstruction of the biliary hila and a contralateral portal vein steno-occlusion. Materials and Methods Sixty patients with a malignant hilar obstruction and unilobar portal vein steno-occlusion caused by tumor invasion or preoperative portal vein embolization were enrolled in this retrospective study from October 2010 to October 2013. All patients were treated with percutaneous placement of a biliary metallic stent, including expanded polytetrafluoroethylene (ePTFE)-covered stents in 27 patients and uncovered stents in 33 patients. Results A total of 70 stents were successfully placed in 60 patients. Procedural-related minor complications, including self-limiting hemobilia (n = 2) and cholangitis (n = 4) occurred in six (10%) patients. Acute cholecystitis occurred in two patients. Successful internal drainage was achieved in 54 (90%) of the 60 patients. According to a Kaplan-Meier analysis, median survival time was 210 days (95% confidence interval [CI], 135-284 days), and median stent patency time was 133 days (95% CI, 94-171 days). No significant difference in stent patency was observed between covered and uncovered stents (p = 0.646). Stent dysfunction occurred in 16 (29.6%) of 54 patients after a mean of 159 days (range, 65-321 days). Conclusion Unilateral placement of ePTFE-covered and uncovered stents in the hepatic lobe with a patent portal vein is a safe and effective method for palliative treatment of patients with a contralateral portal vein steno-occlusion caused by an advanced hilar malignancy or portal vein embolization. No significant difference in stent patency was detected between covered and uncovered metallic stents. PMID:25995688
Hou, Dongming; Narciso, Hugh; Kamdar, Kirti; Zhang, Ping; Barclay, Bruce; March, Keith L
2005-01-01
The effects of nitric acid (NO) on vessel response to injury include the inhibition of platelet adhesion, platelet aggregation, leukocyte adhesion and smooth muscle cell proliferation. Releasing NO from a stent might reduce the clinical problem of restenosis. The present study was designed to examine whether an NO-eluting covered stent can prevent neointimal formation in a porcine carotid overstretch injury model. The interior of a self-expanding polytetrafluoroethylene (ePTFE)-covered aSpire stent was coated with silicone, which contained 23.6 microg or 54.5 microg sodium nitroprusside (SNP, NO-releasing compound). The stent was implanted into carotid artery. Six pigs were implanted with stents, one high-dose SNP and one uncoated control, following balloon overstretch injury of the carotid artery with a balloon-to-artery ratio of 1.3:1. No local or systemic toxicity was evidenced in the six pigs after carotid artery implantation with either low- or high-dose stents within a week. At day 28, the mean intimal thickness was 0.12 +/- 0.05 mm for NO-eluting stents and 0.43 +/- 0.09 mm for uncoated stents (p = 0.008). The mean neointimal area was reduced from 2.40 +/- 0.39 mm2 for control stents to 0.49 +/- 0.16 mm2 for NO-eluting stents (p < 0.0001), which resulted in a 24% reduction of angiographic vessel narrowing. The NO-eluting ePTFE-covered stent is feasible and effectively reduces in-stent neointimal hyperplasia at 28 days in a porcine carotid overstretch model.
Reflectance of polytetrafluoroethylene for xenon scintillation light
NASA Astrophysics Data System (ADS)
Silva, C.; Pinto da Cunha, J.; Pereira, A.; Chepel, V.; Lopes, M. I.; Solovov, V.; Neves, F.
2010-03-01
Gaseous and liquid xenon particle detectors are being used in a number of applications including dark matter search and neutrino-less double beta decay experiments. Polytetrafluoroethylene (PTFE) is often used in these detectors both as electrical insulator and as a light reflector to improve the efficiency of detection of scintillation photons. However, xenon emits in the vacuum ultraviolet (VUV) wavelength region (λ ≃175 nm) where the reflecting properties of PTFE are not sufficiently known. In this work, we report on measurements of PTFE reflectance, including its angular distribution, for the xenon scintillation light. Various samples of PTFE, manufactured by different processes (extruded, expanded, skived, and pressed) have been studied. The data were interpreted with a physical model comprising both specular and diffuse reflections. The reflectance obtained for these samples ranges from about 47% to 66% for VUV light. Other fluoropolymers, namely, ethylene tetrafluoroethylene (ETFE), fluorinated ethylene propylene (FEP), and perfluoro-alkoxyalkane (PFA) were also measured.
Engineering based assessment for a shape design of a pediatric ePTFE pulmonary conduit valve.
Tsuboko, Yusuke; Shiraishi, Yasuyuki; Yamada, Akihiro; Yambe, Tomoyuki; Miura, Hidekazu; Mura, Seitaro; Yamagishi, Masaaki
2016-08-01
The authors examined the hemodynamic characteristics of expanded polytetrafluoroethylene (ePTFE) pulmonary valved conduits quantitatively by our originally developed pediatric pulmonary mechanical circulatory system, in order to suggest the optimal shape design. The system consisted of pneumatically driven right atrium and ventricle model, a pulmonary valve chamber, and elastic pulmonary compliance model with peripheral vascular resistance units, a venous reservoir. We employed two different types of ePTFE valve and evaluated the relationship between the leaflets motion and hemodynamic characteristics by using a high-speed video camera. As a result, we successfully reproduced hemodynamic simulations in our pediatric pulmonary mock system. We confirmed that the presence of bulging sinuses in the pulmonary valved conduit reduced the transvalvular energy loss and increased the valve opening area during systolic period. Our engineering-based in vitro analysis could be useful for proposing a shape design optimization of sophisticated pediatric ePTFE pulmonary valve.
NASA Astrophysics Data System (ADS)
Peng, Shiguang; Guo, Yue; Xie, Guoxin; Luo, Jianbin
2018-05-01
This study compares the tribological performance of polytetrafluoroethylene (PTFE) thin film coating reinforced with black phosphorus (BP) or ball-milled graphite (BMG) nanoparticles, so as to elucidate their mechanism of action under reciprocating sliding test conditions. PTFE coatings with 0.5 wt.% BMG (BMG/PTFE) and 0.5 wt.% BP (BP/PTFE) were prepared on GCr15 bearing steel disk by using a spin coater. The friction and wear tests were carried out by using the ball-on-disk tribometer under a normal load of 1 N (contact pressure: 780 MPa), a frequency of 2 Hz, and 4.2 mm sliding displacement amplitude. The surface roughness, wear volume and surface morphology of the coatings were characterized by the three-dimensional white light, and Energy Dispersive X-ray Detector (EDX) analysis coupled with environmental scanning electron microscope (ESEM). It is found that BP/PTFE coating has better anti-wear and anti-friction performances than those of pure PTFE or BMG/PTFE coating. The coating with BP nanoparticles shows excellent tribological properties with the wear volume decreased from 3.52 × 106 μm3 to 1.64 × 106 μm3 and the coefficient of friction (COF) decreased from 0.117 to 0.046. More importantly, the BP layer probably expands and absorbs much energy due to its negative Poisson's ratio phenomenon under reciprocating sliding, and effectively reducing furrow and adhesive wear.
NASA Astrophysics Data System (ADS)
Qi, Dong; Cheng, Yongzhi; Wang, Xian; Wang, Fang; Li, Bowen; Gong, Rongzhou
2017-12-01
In this paper, a polytetrafluoroethylene (PTFE) top-covered multi-layer composite structure PTFE/H s/(Ge/ZnS)3 (H s represents the surface layer ZnS with various thicknesses) for spectral compatibility is proposed and investigated theoretically and experimentally. A substantial decline of glossiness from over 200 Gs to 74.2 Gs could be realized, due to high roughness and interface reflection of the 800 nm PTFE protection layer. In addition, similar to the structure of H s/(Ge/ZnS)3, the designed structure with a certain color exhibits ultra-low emissivity of average 0.196 at 8-14 µm and highly transparent performance of 96.45% in the radar frequency range of 2-18 GHz. Our design will provide an important reference for the practical applications of the spectral compatible multilayer films.
Does expanded polytetrafluoroethylene mesh really shrink after laparoscopic ventral hernia repair?
Carter, P R; LeBlanc, K A; Hausmann, M G; Whitaker, J M; Rhynes, V K; Kleinpeter, K P; Allain, B W
2012-06-01
The shrinkage of mesh has been cited as a possible explanation for hernia recurrence. Expanded polytetrafluoroethylene (ePTFE) is unique in that it can be visualized on computed tomography (CT). Some animal studies have shown a greater than 40% rate of contraction of ePTFE; however, very few human studies have been performed. A total of 815 laparoscopic incisional/ventral hernia (LIVH) repairs were performed by a single surgical group. DualMesh Plus (ePTFE) (WL Gore & Associates, Newark, DE) was placed in the majority of these patients using both transfascial sutures and tack fixation. Fifty-eight patients had postoperative CTs of the abdomen and pelvis with ePTFE and known transverse diameter of the implanted mesh. The prosthesis was measured on the CT using the AquariusNet software program (TeraRecon, San Mateo, CA), which outlines the mesh and calculates the total length. Data were collected regarding the original mesh size, known linear dimension of mesh, seroma formation, and time interval since mesh implantation in months. The mean shrinkage rate was 6.7%. The duration of implantation ranged from 6 weeks to 78 months, with a median of 15 months. Seroma was seen in 8.6% (5) of patients. No relationship was identified between the percentage of shrinkage and the original mesh size (P = 0.78), duration of time implanted (P = 0.57), or seroma formation (P = 0.074). In 27.5% (16) of patients, no shrinkage of mesh was identified. Of the patients who did experience mesh shrinkage, the range of shrinkage was 2.6-25%. Our results are markedly different from animal studies and show that ePTFE has minimal shrinkage after LIVH repair. The use of transfascial sutures in addition to tack fixation may have an implication on the mesh contraction rates.
Beimers, Lijkele; Lam, Patrick H; Murrell, George A C
2014-10-01
This study investigated the biomechanical effects of expanded polytetrafluoroethylene (ePTFE) suture augmentation patches in rotator cuff repair constructs. The infraspinatus tendon in 24 cadaveric ovine shoulders was repaired using an inverted horizontal mattress suture with 2 knotless bone anchors (ArthroCare, Austin, TX, USA) in a lateral-row configuration. Four different repair groups (6 per group) were created: (1) standard repair using inverted horizontal mattress sutures, (2) repair with ePTFE suture augmentations on the bursal side of the tendon, (3) repair with ePTFE suture augmentations on the articular side, and, (4) repair with ePTFE suture augmentations on both sides of the tendon. Footprint contact pressure, stiffness, and the load to failure of the repair constructs were measured. Repairs with ePTFE suture augmentations on the bursal side exerted significantly more footprint contact pressure (0.40 ± 0.01 MPa) than those on the articular side (0.34 ± 0.02 MPa, P = .04) and those on both sides (0.33 ± 0.02 MPa, P = .01). At 15 degrees of abduction, ePTFE-augmented repairs on the bursal side had higher footprint contact pressure (0.26 ± 0.03 MPa) compared with standard repairs (0.15 ± 0.02 MPa, P = .01) and with ePTFE-augmented repairs on the articular side (0.18 ± 0.02 MPa, P = .03). The ePTFE-augmented repairs on the bursal side demonstrated significantly higher failure loads (178 ± 18 N) than standard repairs (120 ± 17 N, P = .04). Inverted horizontal mattress sutures augmented with ePTFE patches on the bursal side of the tendon enhanced footprint contact pressures and the ultimate load to failure of lateral-row rotator cuff repairs in an ovine model. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tanaka, Toshihiro, E-mail: toshihir@bf6.so-net.ne.jp; Guenther, Rolf W., E-mail: guenther@rad.rwth-aachen.de; Isfort, Peter, E-mail: isfort@hia.rwth-aachen.de
Transjugular intrahepatic portosystemic shunt (TIPS) dysfunction is an important problem after creation of shunts. Most commonly, TIPS recanalization is performed via the jugular vein approach. Occasionally it is difficult to cross the occlusion. We describe a hybrid technique for TIPS revision via a direct transhepatic access combined with a transjugular approach. In two cases, bare metal stents or polytetrafluoroethylene (PTFE)-covered stent grafts had been placed in TIPS tract previously, and they were completely obstructed. The tracts were inaccessible via the jugular vein route alone. In each case, after fluoroscopy or computed tomography-guided transhepatic puncture of the stented segment of themore » TIPS, a wire was threaded through the shunt and snared into the right jugular vein. The TIPS was revised by balloon angioplasty and additional in-stent placement of PTFE-covered stent grafts. The patients were discharged without any complications. Doppler sonography 6 weeks after TIPS revision confirmed patency in the TIPS tract and the disappearance of ascites. We conclude that this technique is feasible and useful, even in patients with previous PTFE-covered stent graft placement.« less
ERIC Educational Resources Information Center
Stocker, James D., Jr.; Kubina, Richard M., Jr.
2017-01-01
Fluency, a combination of response accuracy and speed, enables students to work efficiently through academic tasks. Students with disabilities and math deficits often struggle to learn math facts fluently. Although issues with fluency frequently coexist with a disability, problems gaining fluency also stem from a lack of practice and appropriate…
NASA Astrophysics Data System (ADS)
Chiryatyeva, Aleksandra; Trebushat, Dmitry; Prokhorokhin, Aleksei; Khakhalkin, Vladimir; Andreev, Mark; Novokhreschenov, Aleksei; Kretov, Evgeny
2017-12-01
Cardiovascular diseases are the leading cause of death worldwide. Valvular heart disease often requires valve repair or replacement. Today, surgery uses xenograft—porcine or bovine pericardium. However, bioprosthetic valves do not ensure sufficient durability. We investigated 0.6% glutaraldehyde-treated porcine pericardium to define its properties. Using a tensile test stand, we studied characteristics of the polymeric material—expanded polytetrafluoroethylene (ePTFE)—and compared it to xenopericardium. The artificial material provides a better durability; it has higher elastic modulus and ultimate tensile strength. However, ePTFE samples demonstrated direction anisotropy due to extrusion features. It requires the enhancement of quality of the ePTFE sheet or investigation of other polymeric materials to find the adequate replacement for bioprosthetic heart valves.
Solid spherical glass particle impingement studies of plastic materials
NASA Technical Reports Server (NTRS)
Rao, P. V.; Young, S. G.; Buckley, D. H.
1983-01-01
Erosion experiments on polymethyl methacrylate (PMMA), polycarbonate, and polytetrafluoroethylene (PTFE) were conducted with spherical glass beads impacting at normal incidence. Optical and scanning electron microscopic studies and surface profile measurements were made on specimens at predetermined test intervals. During the initial stage of damage to PMMA and polycarbonate, material expands or builds up above the original surface. However, this buildup disappears as testing progresses. Little or no buildup was observed on PTFE. PTFE is observed to be the most resistant material to erosion and PMMA the least. At low impact pressures, material removal mechanisms are believed to be similar to those for metallic materials. However, at higher pressures, surface melting is indicated at the center of impact. Deformation and fatigue appear to play major roles in the material removal process with possible melting or softening.
Fabricating PFPE Membranes for Microfluidic Valves and Pumps
NASA Technical Reports Server (NTRS)
Greer, Frank; White, Victor E.; Lee, Michael C.; Willis, Peter A.; Grunthaner, Frank J.; Rolland, Jason; Rolland, Jason
2009-01-01
A process has been developed for fabricating membranes of a perfluoropolyether (PFPE) and integrating them into valves and pumps in laboratory-on-achip microfluidic devices. Membranes of poly(tetrafluoroethylene) [PTFE] and poly(dimethylsilane) [PDMS] have been considered for this purpose and found wanting. By making it possible to use PFPE instead of PTFE or PDMS, the present process expands the array of options for further development of microfluidic devices for diverse applications that could include detection of biochemicals of interest, detection of toxins and biowarfare agents, synthesis and analysis of proteins, medical diagnosis, and synthesis of fuels.
Efficacy of Two Mathematics Interventions for Enhancing Fluency with Elementary Students
ERIC Educational Resources Information Center
Mong, Michael D.; Mong, Kristi W.
2010-01-01
An alternating treatments design was used to evaluate two curriculum-based mathematics interventions designed to enhance fluency with three elementary school students. Results indicate that both the Math to Mastery (MTM) intervention and the Cover, Copy, Compare (CCC) intervention were effective at increasing mathematics fluency, as measured by…
Kim, Young-Suk Grace
2015-01-01
The primary goal was to expand our understanding of text reading fluency (efficiency or automaticity)-how its relation to other constructs (e.g., word reading fluency and reading comprehension) changes over time and how it is different from word reading fluency and reading comprehension. We examined (1) developmentally changing relations among word reading fluency, listening comprehension, text reading fluency, and reading comprehension; (2) the relation of reading comprehension to text reading fluency; (3) unique emergent literacy predictors (i.e., phonological awareness, orthographic awareness, morphological awareness, letter name knowledge, vocabulary) of text reading fluency vs. word reading fluency; and (4) unique language and cognitive predictors (e.g., vocabulary, grammatical knowledge, theory of mind) of text reading fluency vs. reading comprehension. These questions were addressed using longitudinal data (two timepoints; Mean age = 5;24 & 6;08) from Korean-speaking children ( N = 143). Results showed that listening comprehension was related to text reading fluency at time 2, but not at time 1. At both times text reading fluency was related to reading comprehension, and reading comprehension was related to text reading fluency over and above word reading fluency and listening comprehension. Orthographic awareness was related to text reading fluency over and above other emergent literacy skills and word reading fluency. Vocabulary and grammatical knowledge were independently related to text reading fluency and reading comprehension whereas theory of mind was related to reading comprehension, but not text reading fluency. These results reveal developmental nature of relations and mechanism of text reading fluency in reading development.
Kim, Young-Suk Grace
2015-01-01
The primary goal was to expand our understanding of text reading fluency (efficiency or automaticity)—how its relation to other constructs (e.g., word reading fluency and reading comprehension) changes over time and how it is different from word reading fluency and reading comprehension. We examined (1) developmentally changing relations among word reading fluency, listening comprehension, text reading fluency, and reading comprehension; (2) the relation of reading comprehension to text reading fluency; (3) unique emergent literacy predictors (i.e., phonological awareness, orthographic awareness, morphological awareness, letter name knowledge, vocabulary) of text reading fluency vs. word reading fluency; and (4) unique language and cognitive predictors (e.g., vocabulary, grammatical knowledge, theory of mind) of text reading fluency vs. reading comprehension. These questions were addressed using longitudinal data (two timepoints; Mean age = 5;24 & 6;08) from Korean-speaking children (N = 143). Results showed that listening comprehension was related to text reading fluency at time 2, but not at time 1. At both times text reading fluency was related to reading comprehension, and reading comprehension was related to text reading fluency over and above word reading fluency and listening comprehension. Orthographic awareness was related to text reading fluency over and above other emergent literacy skills and word reading fluency. Vocabulary and grammatical knowledge were independently related to text reading fluency and reading comprehension whereas theory of mind was related to reading comprehension, but not text reading fluency. These results reveal developmental nature of relations and mechanism of text reading fluency in reading development. PMID:26435550
NASA Astrophysics Data System (ADS)
Shi, Zhiquan; Zhou, Hui; Qing, Xutang; Dai, Tingyang; Lu, Yun
2012-06-01
Porous poly(tetrafluoroethylene) (PTFE) membranes play an important role in air purification and separation engineering. To achieve the bi-functionality of conducting and antibacterial property, two kinds of poly(tetrafluoroethylene)@ polypyrrole/nano-silver composite membranes have been prepared. One involves hydrophobic polypyrrole/nano-silver composite with hollow capsule nanostructures immobilized on the surface of the PTFE membranes. The other is a type of composite membranes with polypyrrole/nano-silver composite wholly packed on the fibrils of the expand PTFE membrane to form core/shell coaxial cable structures. The structure and morphology of the two kinds of composite membranes have been characterized by FTIR, UV-vis, XRD, TGA and SEM measurements. Possible formation mechanisms of the hollow capsules and the core/shell nanocable structures have been discussed in detail. The antibacterial effects of composite membranes are also briefly investigated.
Jet blown PTFE for control of biocompatibility
NASA Astrophysics Data System (ADS)
Leibner, Evan Scott
The development of fully hemocompatible cardiovascular biomaterials will have a major impact on the practice of modern medicine. Current artificial surfaces, unlike native vascular surfaces, are not able to control clot and thrombus formation. Protein interactions are an important component in hemocompatibility and can result in decreased patency due to thrombus formation or surface passivation which can improve endothelization. It is believed that controlling these properties, specifically the nanometer sizes of the fibers on the material's surface, will allow for better control of biological responses. The biocompatibility of Teflon, a widely used polymer for vascular grafts, would be improved with nanostructured control of surface features. Due to the difficultly in processing polytetrafluoroethylene (PTFE), it has not been possible to create nanofibrous PTFE surfaces. The novel technique of Jet Blowing allows for the formation of nanostructured PTFE (nPTFE). A systematic investigation into controlling polymer properties by varying the processing conditions of temperature, pressure, and gas used in the Jet Blowing allows for an increased understanding of the effects of plasticization on the material's properties. This fundamental understanding of the material science behind the Jet Blowing process has enabled control of the micro and nanoscale structure of nPTFE. While protein adsorption, a key component of biocompatibility, has been widely studied, it is not fully understood. Major problems in the field of biomaterials include a lack of standard protocols to measure biocompatibility, and inconstant literature on protein adsorption. A reproducible protocol for measuring protein adsorption onto superhydrophobic surfaces (ePTFE and nPTFE) has been developed. Both degassing of PBS buffer solutions and evacuation of the air around the expanded PTFE (ePTFE) prior to contact with protein solutions are essential. Protein adsorption experiments show a four-fold difference in the measure of proteins adsorbed using radiometry (I-125 labeled human serum albumin (HSA)) and electrophoresis (unlabeled HSA). This provides evidence that the standard method of radiolabeled protein for measuring adsorption does not fully account for changes to the HSA molecules due to labeling. The differences between measured protein values can be attributed to the radiolabel affecting the HSA hydrophobicity resulting in a change in the protein's interactions with the hydrophobic surface. Additionally, our work has provided repeatable results showing that the amount of protein adsorbed onto the polymer surface, after washing, accounted for only 65% of the amount of protein that was removed from solution based on depletion analysis. This implies that measurement of the amount of strongly bound protein on the material significantly underestimates the actual amount of protein adsorbing into the surface region of the material interface. HSA adsorption isotherms demonstrate an increase in protein adsorption capacity on the nPTFE surface compared to adsorption on the same surface area of ePTFE. Preliminary cell work shows that the nPTFE surfaces had a larger number of cells growing on the surface of the material when compared to ePTFE surfaces. The research also shows that while most endothelial cells were not viable on the ePTFE surface after 96 hours, they remained alive on the nPTFE surface during that same time period. Surface functionalization using ammonia plasma has been performed. X-ray photoelectron spectroscopy (XPS) analysis revealed the presence of amine groups on the nPTFE surface. The amine groups can be used to couple polypeptides onto the PTFE surface in the future. The selection of different peptides will allow for selective control of cell adhesion. This research shows that nPTFE has potential for improved biocompatibility over standard ePTFE, based on increased protein adsorption capacity, increased viability of endothelial cells, and the ability to plasma modify the PTFE surface.
ERIC Educational Resources Information Center
Poncy, Brian C.; Skinner, Christopher H.; McCallum, Elizabeth
2012-01-01
An adapted alternating treatments design was used to compare the effects of class-wide applications of Taped Problems (TP) and Cover, Copy, and Compare (CCC) procedures designed to enhance subtraction fact fluency in an intact third-grade classroom. During the TP procedure, a tape provided an auditory prompt (i.e., the problem), followed by a…
NASA Astrophysics Data System (ADS)
Sbai, Marouan
Plasma surface modification is commonly used in biomedical field, for example to enhance cell adhesion and growth surrounding the stent covers without affecting its bulk properties. Plasma polymer (PP) deposition used to create thin films rich in functional groups, e.g. primary amines, known to enhance the cellular response and allow grafting of biomolecules especially on stent grafts. Thin film adhesion to stent polymeric cover should be considered especially as they will evolve in a biological environment. The aim of this project is to evaluate the adhesion of PP on polytetrafluoroethylene (PTFE) and polyethyleneterephthalate (PET). Thereafter, an ammonia plasma treatment on PTFE is performed prior to deposition of PP to optimize the PP/PTFE adhesion. PP studied here (referred to as "LP") is prepared from a mixture of ethylene (C2H4) and ammonia (NH3). It is deposited on two supports, PET and PTFE. The interfacial adhesion between the LP coating and the substrate was evaluated by "Peel-test 180 °" according to ASTM F1842. Staining of the surface after peel test followed by an image analysis was performed to determine the percentage of removed coating. Adhesion optimization is done by varying operating plasma parameters such as power, pressure and pretreatment time. Chemical analyses and wettability of LP and pretreated surfaces in dry and wet conditions are characterized by XPS and contact angle measurements, respectively. The adhesion of LP/PET was excellent in a dry environment (<1%), but lower under wet conditions (4+/-6% and 44+/-7% as minimum and maximum values at 5min and 60min of immersion in deionized water, respectively). However, 56% to 75% of the LP is removed from virgin PTFE in a dry and wet environment, respectively; percentages can be substantially reduced by plasma pretreatment (0% and 8+/-3% in air and 30min in deionized water). Almost no delamination was observed with NH3 plasma pretreatment at 15s, 100 mTorr and 50W. N2 plasma pretreatment, for comparison, proves much less effective. The LP/PTFE adhesion is considerably improved by plasma pretreatment compared to untreated samples. The chemical LP composition and the cell growth on LP/pretreated PTFE are not significantly affected by this pretreatment. Further investigations are required to explain the LP/PET low adhesion in wet conditions.
Armentano, Ricardo L; Santana, Daniel Bia; Cabrera Fischer, Edmundo I; Graf, Sebastián; Cámpos, Héctor Pérez; Germán, Yanina Zócalo; Carmen Saldías, Maria Del; Alvarez, Inés
2006-02-01
The surgical options in arterial reconstruction are: the use of autologous arteries; autologous veins; or expanded polytetrafluoroethylene (ePTFE) grafts. However, the development of intimal hyperplasia when using veins or ePTFE grafts has been associated with graft failure. Since autologous arteries are not always available, the use of cryopreserved arteries has to be considered. The aims of this study were: (a) to compare the viscoelastic properties of stored cryopreserved arteries and fresh arteries by in vitro analysis; and (b) to compare the viscoelastic properties of arteries measured non-invasively in normotensive patients, with fresh arteries, cryopreserved arteries, and ePTFE segments. The viscoelastic studies were performed in normotensive patients using stress-strain analysis with non-invasive measurement of pressure and diameter in the common carotid artery, and in vitro measurements of pressure and diameter in arteries and prostheses. The in vitro studies showed that the elastic modulus (E), viscous modulus (eta), Stiffness Index (SI), Peterson modulus (Ep), and the pulse wave velocity (PWV) values for human cryopreserved carotid arteries were similar to the values obtained non-invasively in normotensive subjects (P>0.05) and to human fresh vessels (P>0.05). In vitro, the SI, Ep, PWV, and E values of ePTFE were significantly higher than the observed values in subjects and with fresh and cryopreserved arteries (P<0.05); on the other hand the ePTFE eta values were the lowest (P<0.05). We concluded that cryopreserved arteries have similar viscoelastic properties to those obtained in vivo in the arteries of normotensive subjects and in vitro in fresh arteries. Consequently, we conclude that the cryopreservation procedure does not modify the mechanical properties of the arterial wall.
ERIC Educational Resources Information Center
Poncy, Brian C.; Skinner, Christopher H.; Jaspers, Kathryn E.
2007-01-01
An adapted alternating treatments design was used to evaluate and compare the effects of two procedures designed to enhance math fact accuracy and fluency in an elementary student with low cognitive functioning. Results showed that although the cover, copy, compare (CCC) and the taped problems (TP) procedures both increased the student's math fact…
2017-01-24
Objectives: Open surgical reconstruction using expanded polytetrafluoroethylene stent grafts to create a sutureless anastomosis is an alternative to...French Argyle shunt was inserted into one randomly assigned artery, with a self-expanding ePTFE stent deployed in the other. Arterial flow measurements...for histopathology were obtained during the terminal procedure. Results: Angiography revealed no difference in patency at 72 hours. The stent grafts
NASA Astrophysics Data System (ADS)
Wang, Shunzhong; Li, Xiaohui; Wan, Zhaohui; Chen, Yanan; Tan, Jinting; Pan, Mu
2018-03-01
Oxygen transport resistance (OTR) is a critical factor influencing the performance of proton exchange membrane fuel cells (PEMFCs). In this paper, an effective method to reduce the OTR of catalyst layers (CLs) by introducing a hydrophobic additive into traditional CLs is proposed. A low-molecular-weight polytetrafluoroethylene (PTFE) is selected for its feasibility to prepare an emulsion, which is mixed with a traditional catalyst ink to successfully fabricate the CL with PTFE of 10 wt%. The PTFE film exists in the mesopores between the carbon particles. The limiting current of the hydrophobic CL was almost 4000 mA/cm2, which is 500 mA/cm2 higher than that of the traditional CL. PTFE reduces the OTR of the CL in the dry region by as much as 24 s/m compared to the traditional CL and expands the dry region from 2000 mA/cm2 in the traditional CL to 2500 mA/cm2. Furthermore, the CL with the hydrophobic agent can improve the oxygen transport in the wet region (>2000 mA/cm2) more effectively than that in the dry region. All these results indicate that the CL with the hydrophobic agent shows a superior performance in terms of optimizing water management and effectively reduces the OTR in PEMFCs.
A new method for the adjustment of neochordal length: the adjustable slip knot technique.
Yano, Mitsuhiro; Sakaguchi, Syuuhei; Furukawa, Kohji; Nakamura, Eisaku
2015-08-01
The use of expanded polytetrafluoroethylene (ePTFE) sutures for the correction of mitral valve prolapse has become a standardized procedure. Adjustment of neochordal length is crucial to the efficacy of this technique. Various methods have been described for this purpose; however, the fine adjustment of neochordal length is technically challenging. We describe a simple and effective technique for the implantation of neochordae, which we have termed the 'adjustable slip knot technique'. The first step of this technique is reinforcement of the papillary muscle by a Teflon pledget with or without polytetrafluoroethylene (CV-4) loops. The second step is the formation of a neochordal loop by introducing an ePTFE suture between the affected mitral leaflet and the papillary muscle or ePTFE loops. The third step is the adjustment of the length of neochordae. The formation of a slip knot in one arm of the ePTFE suture is the pivot of this technique. The neochordal loop can be constricted by the application of tension to one arm of the suture. We applied this technique in 5 patients with satisfactory results. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Update on Didactic and Clinical Education in Fluency Disorders: 2013-2014.
Scott Yaruss, J; Lee, Jieun; Kikani, Kaya B; Leslie, Paula; Herring, Caryn; Ramachandar, Sujini; Tichenor, Seth; Quesal, Robert W; McNeil, Malcolm R
2017-02-01
This study surveyed didactic and clinical education in fluency disorders at undergraduate and graduate institutions in the United States that provide education in speech-language pathology to determine whether a previously observed reduction in requirements has continued since prior surveys (Yaruss, 1999; Yaruss & Quesal, 2002). The study involved a detailed questionnaire that was sent to 282 communication science and disorders departments. Questions examined didactic and clinical education, as well as faculty knowledge about fluency disorders. Comparisons with prior surveys revealed several findings, including (a) on average, programs have increased academic coursework and incorporated more practical sessions and competency-based testing in the classroom; (b) the number of faculty who possess extensive clinical experience with fluency disorders has decreased; and (c) although an increase in clinical requirements in fluency disorders was detected, the number of programs providing minimal education about fluency disorders remains high. Given an expanding scope of practice, many programs have continued to try to provide adequate education about fluency disorders. Still, direct clinical experiences are limited, and faculty expertise in this area has continued to decrease. To raise students' confidence and competence in fluency disorders, efforts beyond graduate work-or systemic changes in the profession-may be necessary.
MRSA-infected external iliac artery pseudoaneurysm treated with endovascular stenting.
Clarke, M G; Thomas, H G; Chester, J F
2005-01-01
A 48-year-old woman with severe juvenile-onset rheumatoid arthritis presented with a bleeding cutaneous sinus distal to her right total hip replacement scar. Methicillin resistant Staphylococcus aureus (MRSA) was isolated on culture. She had previously undergone bilateral total hip and knee replacements at aged 23 and six years later had the right knee prosthesis removed for infection, with subsequent osteomyelitis of the femoral shaft and right total hip prosthesis disruption. Peripheral arteriography was performed in view of persistent bleeding from the sinus, which revealed a 6 cm false aneurysm filling from and compressing the right external iliac artery (EIA). A PTFE-covered, balloon expandable JOSTENT was deployed in the right EIA, successfully excluding the false aneurysm and preventing further bleeding from the sinus. No graft infection was reported at 12 months. This case illustrates the potential use of endovascular stent-grafting in the treatment of an infected pseudoaneurysm.
MRSA-Infected External Iliac Artery Pseudoaneurysm Treated with Endovascular Stenting
DOE Office of Scientific and Technical Information (OSTI.GOV)
Clarke, M.G.; Thomas, H.G.; Chester, J.F.
2005-04-15
A 48-year-old woman with severe juvenile-onset rheumatoid arthritis presented with a bleeding cutaneous sinus distal to her right total hip replacement scar. Methicillin resistant Staphylococcus aureus (MRSA) was isolated on culture. She had previously undergone bilateral total hip and knee replacements at aged 23 and six years later had the right knee prosthesis removed for infection, with subsequent osteomyelitis of the femoral shaft and right total hip prosthesis disruption. Peripheral arteriography was performed in view of persistent bleeding from the sinus, which revealed a 6 cm false aneurysm filling from and compressing the right external iliac artery (EIA). A PTFE-covered,more » balloon expandable JOSTENT was deployed in the right EIA, successfully excluding the false aneurysm and preventing further bleeding from the sinus. No graft infection was reported at 12 months. This case illustrates the potential use of endovascular stent-grafting in the treatment of an infected pseudoaneurysm.« less
Wilkoff, Bruce L; Belott, Peter H; Love, Charles J; Scheiner, Avram; Westlund, Randy; Rippy, Marian; Krishnan, Mohan; Norlander, Barry E; Steinhaus, Bruce; Emmanuel, Janson; Zeller, Peter J
2005-03-01
Permanent leads with shocking coils for defibrillation therapy are sometimes implanted in the coronary sinus (CS) and great cardiac vein (GCV). These shocking coils, as documented by pathologic examination of animal investigations, often become tightly encapsulated by fibrosis and can be very difficult to remove. One of three configurations of the Guidant model 7109 Perimeter coronary sinus shocking lead was implanted into the distal portion of the GCV of 24 sheep for up to 14 months. Group 1 had unmodified coils (control), group 2 had coils backfilled with medical adhesive (MA), and Group 3 had coils coated with expanded polytetrafluoroethylene (ePTFE). Eighteen leads, three from each group at 6 and 14 months were transvenously extracted from the left jugular vein. The remaining six animals were not subject to extraction. All animals were euthanized for pathological and microscopic examination. All six of the control, three of the MA, and one of the ePTFE leads required the use of an electrosurgical dissection sheath (EDS) for extraction. Five control, two MA, and none of the ePTFE leads had significant fibrotic attachments to the shocking coils. Significant trauma was observed at necropsy for those leads requiring the use of the EDS for extraction. Tissue ingrowth is a major impediment to the removal of defibrillation leads implanted in the CS and GCV of sheep. Reduction of tissue ingrowth by coating the shocking coils with ePTFE or by backfilling with MA facilitates transvenous lead removal with reduced tissue trauma.
Hu, Yun-Tao; Pan, Xu-Dong; Zheng, Jun; Ma, Wei-Guo; Sun, Li-Zhong
2017-08-01
To date, clinically available expanded polytetrafluoro-ethylene (ePTFE) vascular grafts are suboptimal for reconstructing small caliber (D < 6 mm) arteries, owing to thrombosis in early and restenosis in late stage. Our aim in this preliminary study was to fabricate a nano-fibrous vascular graft which was biofunctionalized with VEGF 165 and heparin. The short term performance was evaluated both in vitro and in vivo. Four-mm caliber grafts were prepared by the coaxial-elctrospun technique, which consisted of poly(l-lactide-co-caprolactone) [P(LLA-CL)] collagen and elastin. Heparin and endothelial cell growth factor-165 (VEGF 165 ) were encapsulated in the core of the fibrous. Controlled release of the heparin and VEGF 165 were evaluated for 28 days. Endothelial cells were cultured on the electrospun grafts or ePTFE grafts as controls. The cellular adhesion, proliferation and morphology were examined. Electrospun or ePTFE grafts were randomly implanted into a rabbit infrarenal aortic replacement model (n = 30) for 28 days without any antiplatelet therapy. At the termination, all grafts were examined by Doppler ultrasound and then evaluated with histology and scanning electron microscopy. The cumulative release amount of heparin (6.93 ± 1.03 mg) and VEGF 165 (22.17 ± 5.56 μg) during 28 days were measured. Endothelial cells cultured on electrospun grafts showed significantly higher attachment efficiency and proliferation compared to the ePTFE ones (P < 0.001). At 2 h more ECs had attached to the P(LLA-CL)/Collagen/Elatin grafts (83.26 ± 8.02%) compared to P(LLA-CL) (67.07 ± 4.16%) and ePTFE (46.87 ± 8.85%). ECs proliferated faster on VEGF loaded grafts (O.D = 2.9 ± 1.2, n = 12) compared to ePTFE (O.D = 1.7 ± 1.0, n = 12). The patency was significantly higher in electrospun grafts (86.6%) than ePTFE grafts (40.0%) (P = 0.021). Correspondingly, the microscope images of electrospun implants showed little thrombus when compared with the ePTFE implants. Biofunctionalized electrospun graft showed surgical properties, hemocompatibility and higher short-term patency compared with the ePTFE grafts. Despite good early performances, profound study should be designed for long-term evaluation. Copyright © 2017 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
La, Mao; Zhou, Huaijuan; Li, Ning; Xin, Yunchuan; Sha, Ren; Bao, Shanhu; Jin, Ping
2017-05-01
The magnesium based switchable mirrors can reversibly change their optical properties between the transparent and the reflective state as a result of hydrogenation and dehydrogenation. These films can potentially be applied as new energy-saving windows, by controlling the transmittance of solar radiation through the regulation of their reflective state. In this study, magnesium-yttrium (Mg-Y) alloy thin films were prepared using a DC magnetron sputtering method. However, the luminous transmittance in the transparent state and the switching durability of switchable mirrors are too poor to satisfy practical demands. In order to improve the films switching durability, luminous transmittance and the surface functionalization, polytetrafluoroethylene (PTFE) was coated with thermal vacuum deposition for use as the top layer of Mg-Y/Pd switchable mirrors. The PTFE layer had a porous network structure and exhibited a superhydrophobic surface with a water contact angle of approximately 152°. By characterization, PTFE thin films shows the excellent protection role against the oxidization of Mg, the switching durability of the films were improved 3 times, and also shows the antireflection role the luminous transmission of films was enhanced by 7% through the top covered with PTFE.
Mitral valve repair in dogs using an ePTFE chordal implantation device: a pilot study.
Borgarelli, M; Lanz, O; Pavlisko, N; Abbott, J A; Menciotti, G; Aherne, M; Lahmers, S M; Lahmers, K K; Gammie, J S
2017-06-01
Mitral valve (MV) regurgitation due to degenerative MV disease is the leading cause of cardiac death in dogs. We carried out preliminary experiments to determine the feasibility and short-term effects of beating-heart MV repair using an expanded polytetrafluorethylene (ePTFE) chordal implantation device (Harpoon TSD-5) in dogs. This study involved six healthy purpose-bred Beagles (weight range 8.9-11.4 kg). Following a mini-thoracotomy performed under general anesthesia, the TSD-5 was used to place 1 or 2 artificial ePTFE cords on the anterior MV leaflet or the posterior MV leaflet via a left-ventricular transapical approach. The procedure was guided and monitored by transesophageal echocardiography. Postoperative antithrombotic treatment consisted of clopidogrel or a combination of clopidogrel and apixaban. Dogs were serially evaluated by transthoracic echocardiography at day 1, 7, 14, 21, and 30. The hearts were then examined for evaluation of tissues reactions and to detect signs of endothelialization. One or two chords were successfully implanted in five dogs. Four dogs completed the 30 days follow-up. One dog died intra-operatively because of aortic perforation. One dog died early post-operatively from a hemorrhagic pleural effusion attributed to overly aggressive antithrombotic treatment. One dog developed a thrombus surrounding both the knot and the synthetic cord. Postmortem exam confirmed secure placement of ePTFE knots in the mitral leaflets in all dogs and the presence of endothelialization of the knots and chords. These preliminary results demonstrate the feasibility of artificial chordal placement using an ePTFE cordal implantation device in dogs. Copyright © 2017 Elsevier B.V. All rights reserved.
Realization of the Gallium Triple Point at NMIJ/AIST
NASA Astrophysics Data System (ADS)
Nakano, T.; Tamura, O.; Sakurai, H.
2008-02-01
The triple point of gallium has been realized by a calorimetric method using capsule-type standard platinum resistance thermometers (CSPRTs) and a small glass cell containing about 97 mmol (6.8 g) of gallium with a nominal purity of 99.99999%. The melting curve shows a very flat and relatively linear dependence on 1/ F in the region from 1/ F = 1 to 1/ F = 20 with a narrow width of the melting curve within 0.1 mK. Also, a large gallium triple-point cell was fabricated for the calibration of client-owned CSPRTs. The gallium triple-point cell consists of a PTFE crucible and a PTFE cap with a re-entrant well and a small vent. The PTFE cell contains 780 g of gallium from the same source as used for the small glass cell. The PTFE cell is completely covered by a stainless-steel jacket with a valve to enable evacuation of the cell. The melting curve of the large cell shows a flat plateau that remains within 0.03 mK over 10 days and that is reproducible within 0.05 mK over 8 months. The calibrated value of a CSPRT obtained using the large cell agrees with that obtained using the small glass cell within the uncertainties of the calibrations.
Scalable bonding of nanofibrous polytetrafluoroethylene (PTFE) membranes on microstructures
NASA Astrophysics Data System (ADS)
Mortazavi, Mehdi; Fazeli, Abdolreza; Moghaddam, Saeed
2018-01-01
Expanded polytetrafluoroethylene (ePTFE) nanofibrous membranes exhibit high porosity (80%-90%), high gas permeability, chemical inertness, and superhydrophobicity, which makes them a suitable choice in many demanding fields including industrial filtration, medical implants, bio-/nano- sensors/actuators and microanalysis (i.e. lab-on-a-chip). However, one of the major challenges that inhibit implementation of such membranes is their inability to bond to other materials due to their intrinsic low surface energy and chemical inertness. Prior attempts to improve adhesion of ePTFE membranes to other surfaces involved surface chemical treatments which have not been successful due to degradation of the mechanical integrity and the breakthrough pressure of the membrane. Here, we report a simple and scalable method of bonding ePTFE membranes to different surfaces via the introduction of an intermediate adhesive layer. While a variety of adhesives can be used with this technique, the highest bonding performance is obtained for adhesives that have moderate contact angles with the substrate and low contact angles with the membrane. A thin layer of an adhesive can be uniformly applied onto micro-patterned substrates with feature sizes down to 5 µm using a roll-coating process. Membrane-based microchannel and micropillar devices with burst pressures of up to 200 kPa have been successfully fabricated and tested. A thin layer of the membrane remains attached to the substrate after debonding, suggesting that mechanical interlocking through nanofiber engagement is the main mechanism of adhesion.
Evaluation of novel resorbable membranes for bone augmentation in a rat model.
Zeng, Ni; van Leeuwen, Anne; Yuan, Huipin; Bos, Ruud R M; Grijpma, Dirk W; Kuijer, Roel
2016-02-01
Our study compared two novel, biodegradable poly(trimethylene carbonate) (PTMC) barrier membranes to clinically applied barrier membranes in maintaining volume of block autologous bone grafts in a rat mandible model. Two hundred and forty rats were included in this study. Block autologous bone grafts of 5 mm in diameter were harvested from the mandibular angles and transplanted onto the contralateral side. The bone grafts were either covered with a membrane or left uncovered. The applied membranes included pure PTMC membranes, biphasic calcium phosphate (BCP) incorporated PTMC composite membranes, expanded poly(tetrafluoroethylene) (e-PTFE) membranes (Tex) and collagen membranes (Geistlich Bio-Gide). After 2, 4 and 12 weeks, the rat mandibles were retrieved and analysed by histological evaluation and μCT quantification. The histological evaluation revealed that in time the block autologous bone graft was well integrated to the recipient bone via gradually maturing newly formed bone and did not show signs of resorption, independent of membrane coverage or types of membrane. μCT quantification showed the volume of the bone graft and recipient bone together was maintained by new bone formation and recipient bone resorption. Our study showed that the use of PTMC membranes and PTMC-BCP composite membranes resulted in similar bone remodelling to the collagen membranes and e-PTFE membranes and that the use of barrier membranes did not interfere with bone remodelling of the bone grafts and recipient bones. However, the used barrier membranes seemed not to contribute in maintaining the volume of block autologous bone grafts. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Dilatation of aortic grafts over time: what to expect and when to be concerned.
Schroeder, Torben V; Eldrup, Nikolaj; Just, Sven; Hansen, Marc; Nyhuus, Bo; Sillesen, Henrik
2009-06-01
Dilatation of aortic prosthetic grafts is commonly reported, but most reports are anecdotal, with little objective data in the literature. We performed a prospective trial of 303 patients who underwent prosthetic graft repair for aortic aneurysm or occlusive disease, randomizing patients between insertion of a woven polyester or expanded polytetrafluoroethylene (ePTFE) graft. Patients were followed with computed tomography and ultrasonography for up to 5 years in order to assess the frequency and magnitude of postoperative dilatation. Graft dilatation was documented in patients with polyester grafts at 12 months. Thereafter and up to 60 months, polyester grafts did not dilate further. After 5 years, polyester prostheses had dilated by 25% and ePTFE by 12.5%, as determined by computed tomography imaging. These observations suggest that dilatation of prosthetic grafts is more frequent with knitted polyester grafts compared with ePTFE. Dilatation occurs within the first year after implantation and can be, in part, explained by a discrepancy between the initial nominal graft diameter and its diameter after clamp release, probably due to an in vivo adaptation of the textile structure. Interestingly, graft dilatation did not appear to be associated with an increased frequency of graft-related complications.
ERIC Educational Resources Information Center
Martin, Gale L.
2004-01-01
This article proposes that visual encoding learning improves reading fluency by widening the span over which letters are recognized from a fixated text image so that fewer fixations are needed to cover a text line. Encoder is a connectionist model that learns to convert images like the fixated text images human readers encode into the…
Transport stability of pesticides and PAHs sequestered in polyethylene passive sampling devices.
Donald, Carey E; Elie, Marc R; Smith, Brian W; Hoffman, Peter D; Anderson, Kim A
2016-06-01
Research using low-density polyethylene (LDPE) passive samplers has steadily increased over the past two decades. However, such research efforts remain hampered because of strict guidelines, requiring that these samplers be quickly transported in airtight metal or glass containers or foil wrapped on ice. We investigate the transport stability of model pesticides and polycyclic aromatic hydrocarbons (PAHs) with varying physicochemical properties using polytetrafluoroethylene (PTFE) bags instead. Transport scenarios were simulated with transport times up to 14 days with temperatures ranging between -20 and 35 °C. Our findings show that concentrations of all model compounds examined were stable for all transport conditions tested, with mean recoveries ranging from 88 to 113 %. Furthermore, PTFE bags proved beneficial as reusable, lightweight, low-volume, low-cost alternatives to conventional containers. This documentation of stability will allow for more flexible transportation of LDPE passive samplers in an expanding range of research applications while maintaining experimental rigor.
Transport stability of pesticides and PAHs sequestered in polyethylene passive sampling devices
Donald, Carey E.; Elie, Marc R.; Smith, Brian W.; Hoffman, Peter D.; Anderson, Kim A.
2016-01-01
Research using low-density polyethylene (LDPE) passive samplers has steadily increased over the past two decades. However such research efforts remain hampered because of strict guidelines, requiring that these samplers be quickly transported in airtight metal or glass containers, or foil-wrapped on ice. We investigate the transport stability of model pesticides and polycyclic aromatic hydrocarbons (PAHs) with varying physicochemical properties using polytetrafluoroethylene (PTFE) bags instead. Transport scenarios were simulated with transport times up to 14 days with temperatures ranging between -20 and 35 degrees Celsius. Our findings show that concentrations of all model compounds examined were stable for all transport conditions tested, with mean recoveries ranging from 88% to 113%. Furthermore, PTFE bags proved beneficial as reusable, lightweight, low-volume, low-cost alternatives to conventional containers. This documentation of stability will allow for more flexible transportation of LDPE passive samplers in an expanding range of research applications while maintaining experimental rigor. PMID:26983811
Ward, W Kenneth; Slobodzian, Emily P; Tiekotter, Kenneth L; Wood, Michael D
2002-11-01
We addressed the effect of implant thickness, implant porosity, and polyurethane (PU) chemistry on angiogenesis and on the foreign body response in rats. The following materials were implanted subcutaneously for 7 weeks then excised for histologic analysis: a solid PU; a solid polyurethane with silicone and polyethylene oxide (PU-S-PEO); porous expanded polytetrafluoroethylene (ePTFE); and porous polyvinyl alcohol sponge (PVA). Two thicknesses of PU-S-PEO were compared: 300 microns (thin) and 2000 microns (thick). Foreign body capsule (FBC) thickness was much less in PU-S-PEO implants than in PU implants. In addition, FBC were thinner in thin implants than in thick implants. FBC was much more dense in solid implants than in porous implants. As compared with solid implants, porous implants (PVA and ePTFE) led to a marked increase in the number of microvessels that developed adjacent to the implant, as observed both with hematoxylin/eosin staining and with an immunohistochemical anti-endothelial stain. We conclude that the polyethylene oxide and silicone moieties in PU reduce the thickness of the subsequent FBC. In addition, thin implants lead to a thin FBC. Porous implants (PVA and ePTFE) cause more angiogenesis than solid implants. These results may have implications for the measurement of blood-derived analytes by biosensors.
ERIC Educational Resources Information Center
Adams, Katherine; Wiley, Paula
2017-01-01
Iowa Wesleyan University (IW) has historically struggled with both assessment and supporting online students. Newly-appointed librarians and an impending re-accreditation visit prompted an increase in involvement and presence with assessment. In an attempt to expand the library's influence on campus, librarians took on a nontraditional role in the…
NASA Astrophysics Data System (ADS)
Tripathi, S.; De, Rajnarayan; Maidul Haque, S.; Divakar Rao, K.; Misal, J. S.; Prathap, C.; Das, S. C.; Patidar, Manju M.; Ganesan, V.; Sahoo, N. K.
2018-01-01
Present communication focuses on a relatively less explored direction of producing rough polytetrafluoroethylene (PTFE) surfaces for possible hydrophobic applications. The experiments were carried out to make rough PTFE films without losing much of the transmission, which is an important factor while designing futuristic solar cell protection covers. After annealing temperature optimization, as grown RF magnetron sputtered PTFE films (prepared at 160 W RF power) were subjected to vacuum annealing at 200 °C for different time durations ranging from 1 to 4 h. The films show morphological evolution exhibiting formation and growth of columnar nanostructures that are responsible for roughening of the films due to annealing induced molecular migration and rearrangement. In agreement with this, qualitative analysis of corresponding x-ray reflectivity data shows modification in film thickness, which may again be attributed to the growth of columns at the expense of the atoms of remaining film molecules. However, the observations reveal that the film annealed at 200 °C for 2 h gives a combination of patterned columnar structures and reasonable transmission of >85% (in 500-1000 nm wavelength range), both of which are deteriorated when the films are annealed either at high temperature beyond 200 °C or for long durations >3 h. In addition, attenuated total reflection-Fourier transform infrared spectroscopy results reveal that the molecular bonds remain intact upon annealing at any temperature within the studied range indicating the stable nature of the films.
ERIC Educational Resources Information Center
Grafman, Joel M.; Cates, Gary L.
2010-01-01
This study compared the fluency and error rates produced when using the Cover, Copy, and Compare (CCC) and a modified CCC procedure (MCCC) called Copy, Cover, and Compare to complete subtraction math problems. Two second-grade classrooms consisting of 47 total students participated in the study. The following items were administered to…
Ames, Kenneth R.; Doesburg, James M.
1987-01-01
A well pump includes a piston and an inlet and/or outlet valve assembly of special structure. Each is formed of a body of organic polymer, preferably PTFE. Each includes a cavity in its upper portion and at least one passage leading from the cavity to the bottom of the block. A screen covers each cavity and a valve disk covers each screen. Flexible sealing flanges extend upwardly and downwardly from the periphery of the piston block. The outlet valve block has a sliding block and sealing fit with the piston rod.
Hernández-Enríquez, Marco; Lairez, Olivier; Campelo-Parada, Francisco; Lhermusier, Thibault; Bouisset, Frédéric; Roncalli, Jérôme; Elbaz, Meyer; Carrié, Didier; Boudou, Nicolas
2018-05-28
To compare outcomes in patients receiving polytetrafluoroethylene (PTFE) and polyurethane (PL) covered stents (CS) after coronary artery perforation (CAP). The prognosis of CAP has improved with the advent of CSs. Information is scarce about the outcomes of new-generation CSs. Sixty-one patients were treated with CSs in a 5-years period (age = 77 ± 8.75% males). Procedural and clinical data were retrospectively collected. The primary endpoint was procedural success. Secondary endpoints included death and major adverse cardiac events (MACE) defined as a composite of death, myocardial infarction, target vessel, and lesion revascularization and need for surgical repair). Twenty-two (36%) received PL-CSs and 39 (65%) PTFE-CSs. There were no differences in procedural success (86% vs 69%, P = 0.216). Time to deliver was shorter with PL-CS despite larger length of stents (8[11] vs 15[16] min, P = 0.001; 20[5] vs 16[3] mm, P < 0.001). This group had lower rate of pericardial effusion and cardiac arrest (41% vs 72%, P = 0.028; 5% vs 26%, P = 0.045). At 1-year follow-up, MACE rates were similar (58% vs 56%, P = 1.000) with atrend toward TVR in the PL-CS arm (21% vs 5%, P = 0.083). No differences were found in mortality (26% vs 41%, P = 0.385). Each group had 1 stent thrombosis and in-stent restenosis trended higher in the PL-CS group (12% vs 3%, P = 0.223). Time to deliver was shorter with the PL-CS and resulted in lower rate of pericardial effusion and cardiac arrest. However, there were no significant differences in procedural success and 1-year follow-up MACE in patients treated with PL-CS or PTFE-CS. © 2018, Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Li, Jingye; Ichizuri, Shogo; Asano, Saneto; Mutou, Fumihiro; Ikeda, Shigetoshi; Iida, Minoru; Miura, Takaharu; Oshima, Akihiro; Tabata, Yoneho; Washio, Masakazu
2005-07-01
Thin PTFE membranes were prepared by coating the PTFE dispersion onto the aluminum films. Thus the thin crosslinked PTFE (RX-PTFE) membranes were obtained by means of electron beam irradiation above the melting temperature of PTFE under oxygen-free atmosphere. The RX-PTFE membranes were pre-irradiated and grafted by styrene with or without divinylbenzene (DVB) in liquid phase. The existence of DVB accelerated the initial grafting rate. The styrene grafted RX-PTFE membranes are white colored, on the other hand, the styrene/DVB grafted RX-PTFE membranes are colorless. The proton exchange membranes (PEMs) were obtained by sulfonating the grafted membranes using chlorosulfonic acid. The ion exchange capacity (IEC) values of the PEMs ranging from 1.5 to 2.8 meq/g were obtained. The PEMs made from the styrene/DVB grafted membranes showed higher chemical stability than those of the styrene grafted membranes under oxidative circumstance.
Characterization of LANDSAT Panels Using the NIST BRDF Scale from 1100 nm to 2500 nm
NASA Technical Reports Server (NTRS)
Markham, Brian; Tsai, Benjamin K.; Allen, David W.; Cooksey, Catherine; Yoon, Howard; Hanssen, Leonard; Zeng, Jinan; Fulton, Linda; Biggar, Stuart; Markham, Brian
2010-01-01
Many earth observing sensors depend on white diffuse reflectance standards to derive scales of radiance traceable to the St Despite the large number of Earth observing sensors that operate in the reflective solar region of the spectrum, there has been no direct method to provide NIST traceable BRDF measurements out to 2500 rim. Recent developments in detector technology have allowed the NIST reflectance measurement facility to expand the operating range to cover the 250 nm to 2500 nm range. The facility has been modified with and additional detector using a cooled extended range indium gallium arsenide (Extended InGaAs) detector. Measurements were made for two PTFE white diffuse reflectance standards over the 1100 nm to 2500 nm region at a 0' incident and 45' observation angle. These two panels will be used to support the OLI calibration activities. An independent means of verification was established using a NIST radiance transfer facility based on spectral irradiance, radiance standards and a diffuse reflectance plaque. An analysis on the results and associated uncertainties will be discussed.
Ito, Kiyoshi; Aoyama, Tatsuro; Horiuchi, Tetsuyoshi; Hongo, Kazuhiro
2015-12-01
The nonpenetrating titanium clip has been successfully used in peripheral arterial bypass surgery. The purpose of this study was to evaluate the leakage pressures and patterns of nonpenetrating titanium clips using a simple model that mimicked spinal surgery. In addition, the authors describe their surgical experience with these clips and the follow-up results in 31 consecutive patients. The authors compared nonpenetrating titanium clips and expanded polytetrafluoroethylene (ePTFE) sutures in relation to the water pressure that could be tolerated by sutured ePTFE sheets, and the leakage pressure patterns were determined. The changes in leakage pressures at 5 minutes, 30 minutes, and 12 hours were examined when the clips and sutures were used in combination with the mesh-and-glue technique in an in vitro study. Thirty-one patients underwent spinal intradural procedures using nonpenetrating titanium clips to suture the dura maters using the meshand-glue technique, involving fibrin glue and polyglycolic acid-fibrin sheets. A significant difference was apparent between the ePTFE suture group and the nonpenetrating titanium clip group, with the latter showing a leakage pressure that could be sustained and was 1508% higher than that of the former (p = 0.001). In relation to leakage patterns, the nonpenetrating titanium clips did not make any suture holes in the ePTFE sheet and fluid leakage occurred between the clips, whereas fluid leakage was associated with the pressure elevation that occurred at the suture holes made by the ePTFE sutures. Of the 31 patients who underwent spinal intradural procedures using nonpenetrating titanium clips, 1 (3.2%) experienced cerebrospinal fluid (CSF) leakage postoperatively. No other complications-for example, allergic reactions, adhesions, or infections--were encountered. The interrupted placement of nonpenetrating titanium clips enables dural closure without creating any holes. These clips facilitate improvements in the initial leakage pressure and reduce postoperative CSF leakage following spinal surgery. The authors conclude that it is very beneficial to suture the spinal dura mater using nonpenetrating titanium clips given the anatomical characteristics of the spinal dura mater and the fact that the clips do not create suture holes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
El Backly, Rania M.; IRCCS AOU San Martino–IST Istituto Nazionale per la Ricerca sul Cancro, Genova; Faculty of Dentistry, Alexandria University, Alexandria
The present work defines a modified critical size rabbit ulna defect model for bone regeneration in which a non-resorbable barrier membrane was used to separate the radius from the ulna to create a valid model for evaluation of tissue-engineered periosteal substitutes. Eight rabbits divided into two groups were used. Critical defects (15 mm) were made in the ulna completely eliminating periosteum. For group I, defects were filled with a nanohydroxyapatite poly(ester urethane) scaffold soaked in PBS and left as such (group Ia) or wrapped with a tissue-engineered periosteal substitute (group Ib). For group II, an expanded-polytetrafluoroethylene (e-PTFE) (GORE-TEX{sup ®}) membranemore » was inserted around the radius then the defects received either scaffold alone (group IIa) or scaffold wrapped with periosteal substitute (group IIb). Animals were euthanized after 12–16 weeks, and bone regeneration was evaluated by radiography, computed microtomography (μCT), and histology. In the first group, we observed formation of radio-ulnar synostosis irrespective of the treatment. This was completely eliminated upon placement of the e-PTFE (GORE-TEX{sup ®}) membrane in the second group of animals. In conclusion, modification of the model using a non-resorbable e-PTFE membrane to isolate the ulna from the radius was a valuable addition allowing for objective evaluation of the tissue-engineered periosteal substitute.« less
Tordoir, J H; Hofstra, L; Leunissen, K M; Kitslaar, P J
1995-04-01
The purpose of this study was to evaluate the results and complications of standard ePTFE versus stretch ePTFE AV fistulas. Prospective randomised trial. University Hospital. During a 2-year period 37 patients received 17 stretch and 20 standard ePTFE graft AV fistulas. Patients were evaluated for the occurrence of complications and graft patency. Regular Duplex scans were performed to detect stenoses in the fistula circuit. Thrombotic events occurred in 40% of the standard ePTFE grafts, compared to 12% of the stretch ePTFE prostheses (p < 0.001). The incidence of puncture complications was similar in both groups. The cumulative primary patency rate in the stretch ePTFE group was significantly higher compared to the standard ePTFE group (1-year patency rates of 59% and 29%, respectively; p < 0.01). No differences in the duration of puncture site bleeding were observed. Duplex scanning showed a significantly greater number of stenoses in the standard ePTFE grafts. The new stretch ePTFE prosthesis has better primary patency rates and less stenoses due to intimal hyperplasia as compared to standard ePTFE grafts.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chung, Hwan-Hoon, E-mail: chungmic@korea.ac.kr; Lee, Seung Hwa; Cho, Sung Bum
The aim of this study was to determine the feasibility of using a newly designed polytetrafluoroethylene (PTFE)-covered metallic stent in the ureter by comparing its effectiveness with that of the noncovered stent in a canine model. We placed 14 stents in the ureters of seven mongrel dogs that weighed 30-40 kg each. The covered and noncovered stents were deployed in the right and left ureters, respectively, of six dogs. In the seventh dog, a covered stent and a double-J catheter were inserted in the right ureter, and a covered stent only was inserted in the left ureter. The first sixmore » dogs were sacrificed at 5, 10, and 15 weeks after deployment of the stents (two for each follow-up period), and the seventh dog was sacrificed at 30 weeks. There was no migration or poor expansion of any of the stents observed on plain radiography. On intravenous pyelogram and retrograde pyelogram, all of the covered stents at each follow-up period had patent lumens at the stented segments without hydronephrosis, and the passage of contrast material through it was well preserved. The noncovered stents in the dogs sacrificed at 5 and 10 weeks and one of the two dogs sacrificed at 15 weeks showed near-complete occlusion of the stent lumen due to ingrowth of the soft tissue, and severe hydronephrosis was also noted. The noncovered stent in the other dog sacrificed at 15 weeks showed the passage of contrast material without hydronephrosis, but the lumen of the stent was still nearly occluded by the soft tissue. There was no evidence of hydronephrosis or passage disturbance of the contrast material in both ureters of the dog sacrificed at 30 weeks. We conclude that the newly designed PTFE-covered stent effectively prevented the luminal occlusion caused by urothelial hyperplasia compared to the near-total occlusion of the noncovered stents, and no migration of the covered stents was noted.« less
Inferring Master Painters' Esthetic Biases from the Statistics of Portraits
Aleem, Hassan; Correa-Herran, Ivan; Grzywacz, Norberto M.
2017-01-01
The Processing Fluency Theory posits that the ease of sensory information processing in the brain facilitates esthetic pleasure. Accordingly, the theory would predict that master painters should display biases toward visual properties such as symmetry, balance, and moderate complexity. Have these biases been occurring and if so, have painters been optimizing these properties (fluency variables)? Here, we address these questions with statistics of portrait paintings from the Early Renaissance period. To do this, we first developed different computational measures for each of the aforementioned fluency variables. Then, we measured their statistics in 153 portraits from 26 master painters, in 27 photographs of people in three controlled poses, and in 38 quickly snapped photographs of individual persons. A statistical comparison between Early Renaissance portraits and quickly snapped photographs revealed that painters showed a bias toward balance, symmetry, and moderate complexity. However, a comparison between portraits and controlled-pose photographs showed that painters did not optimize each of these properties. Instead, different painters presented biases toward different, narrow ranges of fluency variables. Further analysis suggested that the painters' individuality stemmed in part from having to resolve the tension between complexity vs. symmetry and balance. We additionally found that constraints on the use of different painting materials by distinct painters modulated these fluency variables systematically. In conclusion, the Processing Fluency Theory of Esthetic Pleasure would need expansion if we were to apply it to the history of visual art since it cannot explain the lack of optimization of each fluency variables. To expand the theory, we propose the existence of a Neuroesthetic Space, which encompasses the possible values that each of the fluency variables can reach in any given art period. We discuss the neural mechanisms of this Space and propose that it has a distributed representation in the human brain. We further propose that different artists reside in different, small sub-regions of the Space. This Neuroesthetic-Space hypothesis raises the question of how painters and their paintings evolve across art periods. PMID:28337133
Antibiotic bonding to polytetrafluoroethylene with tridodecylmethylammonium chloride
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harvey, R.A.; Alcid, D.V.; Greco, R.S.
Polytetrafluoroethylene (PTFE) treated with the cationic surfactant, triodecylmethylammonium chloride (TDMAC), binds /sup 14/C-penicillin (1.5 to 2 mg antibiotic/cm graft), whereas untreated PTFE or PTFE treated with anionic detergents shows little binding of antibiotic. TDMAC-treated PTFE concomitantly binds penicillin and heparin, generating a surface that potentially can resist both infection and thrombosis. The retention of these biologically active molecules is not due to passive entrapment in the PTFE but reflects an ionic interaction between the anionic ligands and surface-bound TDMAC. Penicillin bound to PTFE is not removed by exhaustive washing in aqueous buffers but is slowly released in the presence ofmore » plasma or when the PTFE is placed in a muscle pouch in the rat. Muscle tissue adjacent to the treated PTFE shows elevated levels of antibiotic following implantation. PTFE treated with TDMAC and placed in a muscle pouch binds /sup 14/C-penicillin when it is locally irrigated with antibiotic or when penicillin is administered intravenously. Thus, the TDMAC surface treated either in vitro or in vivo with penicillin provides an effective in situ source for the timed release of antibiotic.« less
Study on surface adhesion of Plasma modified Polytetrafluoroethylene hollow fiber membrane
NASA Astrophysics Data System (ADS)
Chen, Jiangrong; Zhang, Huifeng; Liu, Guochang; Guo, Chungang; Lv, Jinglie; Zhangb, Yushan
2018-01-01
Polytetrafluoroethylene (PTFE) is popular membrane material because of its excellent thermal stability, chemical stability and mechanical stability. However, the low surface energy and non-sticky property of PTFE present challenges for modification. In the present study, plasma treatment was performed to improve the surface adhesion of PTFE hollow fiber membrane. The effect of discharge voltage, treatment time on the adhesion of PTFE hollow fiber membrane was symmetrically evaluated. Results showed that the plasma treatment method contributed to improve the surface activity and roughness of PTFE hollow fiber membrane, and the adhesion strength depend significantly on discharge voltage, which was beneficial to seepage pressure of PTFE hollow fiber membrane module. The adhesion strength of PTFE membrane by plasma treated at 220V for 3min reached as high as 86.2 N, far surpassing the adhesion strength 12.7 N of pristine membrane. Furthermore, improvement of content of free radical and composition analysis changes of the plasma modified PTFE membrane were investigated. The seepage pressure of PTFE membrane by plasma treated at 220V for 3min was 0.375 MPa, which means that the plasma treatment is an effective technique to improve the adhesion strength of membrane.
Service life of counter-current chromatography coils.
Conway, Walter D
2007-06-01
A multilayer coil of PTFE tubing, which failed after being used each workday for about 3 years in a type J centrifuge, was examined. Two types of defects were found. One, called crazes, occurs throughout the coil and does not leak initially, but may eventually lead to a short, axially oriented slit. Another, called indentations, is seen primarily in the innermost and other nearby layers. They are elongated, about 5 mm, indentations, usually on the central side of the tubing. These eventually crack and leak. PTFE tubing is permeable to air and hexane and expands by more than 1% when immersed in hexane, heptane or chloroform for a few days. It is suggested that the crazes result from exposure of the somewhat flexible tubing to the undulating centripetal force field in the coil-planet centrifuge, especially when further softened by solvent absorption. The indentations may result from carriage of the excess tubing length, created by solvent absorption, from the coil periphery to the coil center by the centripetal force field, which continuously travels from the peripheral tail to the central head of the coil. A 1% increase in coil length creates 74 cm of excess tubing in the 160-ml coils examined in this study. It is suggested that fluorinated ethylene propylene (FEP) tubing, especially when etched on the outside, may provide more stable CCC coils, since its expansion when exposed to organic solvents is 0.1 or less than that of PTFE.
Ionizing radiation effects on ISS ePTFE jacketed cable assembly
NASA Astrophysics Data System (ADS)
Koontz, S. L.; Golden, J. L.; Lorenz, M. J.; Pedley, M. D.
2003-09-01
Polytetrafluoroethylene (PTFE), which is susceptible to embrittlement by ionizing radiation, is used as a primary material in the Mobile Transporter's (MT) Trailing Umbilical System (TUS) cable on the International Space Station (ISS). The TUS cable provides power and data service between the ISS truss and the MT. The TUS cable is normally stowed in an uptake reel and is fed out to follow the MT as it moves along rails on the ISS truss structure. For reliable electrical and mechanical performance, TUS cable polymeric materials must be capable of >3.5% elongation without cracking or breaking. The MT TUS cable operating temperature on ISS is expected to range between -100°C and +130°C. The on-orbit functional life requirement for the MT TUS cable is 10 years. Analysis and testing were performed to verify that the MT TUS cable would be able to meet full-life mechanical and electrical performance requirements, despite progressive embrittlement by the natural ionizing radiation environment. Energetic radiation belt electrons (trapped electrons) are the principal contributor to TUS cable radiation dose. TUS cable specimens were irradiated, in vacuum, with both energetic electrons and gamma rays. Electron beam energy was chosen to minimize charging effects on the non-conductive ePTFE (expanded PTFE) targets. Tensile testing was then performed, over the expected range of operating temperatures, as a function of radiation dose. When compared to the expected in-flight radiation dose/depth profile, atomic oxygen (AO) erosion of the radiation damaged TUS cable jacket surfaces is more rapid than the development of radiation induced embrittlement of the same surfaces. Additionally, the layered construction of the jacket prevents crack growth propagation, leaving the inner layer material compliant with the design elongation requirements. As a result, the TUS cable insulation design was verified to meet performance life requirements.
Infusing Active Learning into the Research Methods Unit
ERIC Educational Resources Information Center
Bluestone, Cheryl
2007-01-01
The research methods unit of survey psychology classes introduces important concepts of scientific reasoning and fluency, making it an ideal course in which to deliver enhanced curricula. To increase interest and engagement, the author developed an expanded research methods and statistics module to give students the opportunity to explore…
Schmader, Toni; Sedikides, Constantine
2017-10-01
People seek out situations that "fit," but the concept of fit is not well understood. We introduce State Authenticity as Fit to the Environment (SAFE), a conceptual framework for understanding how social identities motivate the situations that people approach or avoid. Drawing from but expanding the authenticity literature, we first outline three types of person-environment fit: self-concept fit, goal fit, and social fit. Each type of fit, we argue, facilitates cognitive fluency, motivational fluency, and social fluency that promote state authenticity and drive approach or avoidance behaviors. Using this model, we assert that contexts subtly signal social identities in ways that implicate each type of fit, eliciting state authenticity for advantaged groups but state inauthenticity for disadvantaged groups. Given that people strive to be authentic, these processes cascade down to self-segregation among social groups, reinforcing social inequalities. We conclude by mapping out directions for research on relevant mechanisms and boundary conditions.
Wang, Li; Sun, Yuhua; Zhou, Xinlin
2016-01-01
Previous studies have observed inconsistent relations between the acuity of the Approximate Number System (ANS) and mathematical achievement. In this paper, we hypothesize that the relation between ANS acuity and mathematical achievement is influenced by fluency; that is, the mathematical achievement test covering a greater expanse of mathematical fluency may better reflect the relation between ANS acuity and mathematics skills. We explored three types of mathematical achievement tests utilized in this study: Subtraction, graded, and semester-final examination. The subtraction test was designed to measure the mathematical fluency. The graded test was more fluency-based than the semester-final examination, but both involved the same mathematical knowledge from the class curriculum. A total of 219 fifth graders from primary schools were asked to perform all three tests, then given a numerosity comparison task, a visual form perception task (figure matching), and a series of other tasks to assess general cognitive processes (mental rotation, non-verbal matrix reasoning, and choice reaction time). The findings were consistent with our expectations. The relation between ANS acuity and mathematical achievement was particularly clearly reflected in the participants’ performance on the visual form perception task, which supports the domain-general explanations for the underlying mechanisms of the relation between ANS acuity and math achievement. PMID:28066291
High-temperature supercapacitor with a proton-conducting metal pyrophosphate electrolyte
Hibino, Takashi; Kobayashi, Kazuyo; Nagao, Masahiro; Kawasaki, Shinji
2015-01-01
Expanding the range of supercapacitor operation to temperatures above 100°C is important because this would enable capacitors to operate under the severe conditions required for next-generation energy storage devices. In this study, we address this challenge by the fabrication of a solid-state supercapacitor with a proton-conducting Sn0.95Al0.05H0.05P2O7 (SAPO)-polytetrafluoroethylene (PTFE) composite electrolyte and a highly condensed H3PO4 electrode ionomer. At a temperature of 200°C, the SAPO-PTFE electrolyte exhibits a high proton conductivity of 0.02 S cm−1 and a wide withstanding voltage range of ±2 V. The H3PO4 ionomer also has good wettability with micropore-rich activated carbon, which realizes a capacitance of 210 F g−1 at 200°C. The resulting supercapacitor exhibits an energy density of 32 Wh kg−1 at 3 A g−1 and stable cyclability after 7000 cycles from room temperature to 150°C. PMID:25600936
The effect of interstitial air on the in vitro thrombogenicity of ePTFE vascular grafts
NASA Technical Reports Server (NTRS)
Rashid, S. N.; Clark, H. G.; Vann, R. D.; Gerth, W. A.; Palmos, L. A.; Mikat, E. M.
1992-01-01
Gas trapped in the interstices of the biomaterials used for vascular prostheses causes thrombosis, and the process of eliminating this gas is known as denucleation. An apparatus was developed for testing in the in vitro effects of denucleation on 4 mm I.D. expanded polytetrafluoroethylene (ePTFE) Vitagraft (Johnson and Johnson). The apparatus was designed to ensure that neither the blood nor the grafts came in contact with air. Blood from a single donor was incubated with control and denucleated grafts for 5, 10, 15, 20, and 30 minutes. The thrombus volume in the graft lumen was measured with a computer assisted videometric system. Little thrombus formed by 5 or 10 minutes, but there was less thrombus in the denucleated graft than in the control graft at all times. The differences were statistically significant at 15 and 20 minutes (p < 0.05). Denucleation nearly doubled the thrombus formation time. Thrombus was more adherent to denucleated grafts than to control grafts. These results are consistent with in vivo observations in the rat where denucleation decreased thrombus formation and increased patency duration.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Liu; Liu, Jinxu, E-mail: liujinxu@bit.edu.cn; Zhang, Xinbo
2015-11-15
Energetic structural material is a kind of materials that are inert under normal conditions but could produce exothermic chemical reaction when subjected to impact. This report shows a kind of energetic structural material of tungsten (W)-polytetrafluoroethylene (PTFE)-aluminum (Al) with density of 4.12 g/cm{sup 3}, excellent ductility and dynamic compressive strength of 96 MPa. Moreover, 50W-35PTFE-15Al (wt%) can exhibit a high reaction energy value of more than 2 times of TNT per unit mass and 5 times of TNT per unit volume, respectively, but with excellent insensitivity compared with traditional explosives. Under thermal conditions, the W-PTFE-Al composite can keep stable atmore » 773 K. Under impact loading, when the strain rate up to ∼4820 s{sup −1} coupled with the absorbed energy per unit volume of 120 J/cm{sup 3}, deflagration occurs and combustion lasts for 500 μs. During impact compressive deformation, the PTFE matrix is elongated into nano-fibers, thus significantly increases the reaction activity of W-PTFE-Al composites. The nano-fiber structure is necessary for the reaction of W-PTFE-Al composites. The formation of PTFE nano-fibers must undergo severe plastic deformation, and therefore the W-PTFE-Al composites exhibit excellent insensitivity and safety. Furthermore, the reaction mechanisms of W-PTFE-Al composites in argon and in air are revealed.« less
NASA Astrophysics Data System (ADS)
Gu, Yu; Li, Qiang
2015-07-01
A new method was developed based on the electron beam vacuum dispersion (EBVD) technology to prepare the PTFE polymer coating of the new polymer quartz piezoelectric crystal sensor for testing liquor products. The new method was applied in the new EBVD equipment which we designed. A real-time system monitoring the polymer coating’s thickness was designed for the new EBVD equipment according to the quartz crystal microbalance (QCM) principle, playing an important role in preparing stable and uniform PTFE polymer coatings of the same thickness. 30 pieces of PTFE polymer coatings on the surface of the quartz crystal basis were prepared with the PTFE polymer ultrafine powder (purity ≥ 99.99%) as the starting material. We obtained 30 pieces of new PTFE polymer sensors. By using scanning electron microscopy (SEM), the structure of the PTFE polymer coating’s column clusters was studied. One sample from the 30 pieces of new PTFE polymer sensors was analysed by SEM in four scales, i.e., 400×, 1000×, 10000×, and 25000×. It was shown that under the condition of high bias voltage and low bias current, uniformly PTFE polymer coating could be achieved, which indicates that the new EBVD equipment is suitable for mass production of stable and uniform polymer coating. Project supported by the National High Technology Research and Development Program of China (Grant No. 2013AA030901).
The Evolution of Transjugular Intrahepatic Portosystemic Shunt: Tips
Fanelli, Fabrizio
2014-01-01
Since Richter's description in the literature in 1989 of the first procedure on human patients, transjugular intrahepatic portosystemic shunt (TIPS) has been worldwide considered as a noninvasive technique to manage portal hypertension complications. TIPS succeeds in lowering the hepatic sinusoidal pressure and in increasing the circulatory flow, thus reducing sodium retention, ascites recurrence, and variceal bleeding. Required several revisions of the shunt TIPS can be performed in case of different conditions such as hepatorenal syndrome, hepatichydrothorax, portal vein thrombosis, and Budd-Chiari syndrome. Most of the previous studies on TIPS procedure were based on the use of bare stents and most patients chose TIPS 2-3 years after traditional treatment, thus making TIPS appear to be not superior to endoscopy in survival rates. Bare stents were associated with higher incidence of shunt failure and consequently patients required several revisions during the follow-up. With the introduction of a dedicated e-PTFE covered stent-graft, these problems were completely solved, No more reinterventions are required with a tremendous improvement of patient's quality of life. One of the main drawbacks of the use of e-PTFE covered stent-graft is higher incidence of hepatic encephalopathy. In those cases refractory to the conventional medical therapy, a shunt reduction must be performed. PMID:27335841
Fabrication and Characteristics of Al/PTFE Multilayers and Application in Micro-initiator
NASA Astrophysics Data System (ADS)
Zhang, Yuxin; Jiang, Hongchuan; Zhao, Xiaohui; Zhang, Wanli; Li, Yanrong
2017-12-01
In this paper, a micro-initiator was designed and fabricated by integrating Al/PTFE multilayers with a Cu film bridge. The regularity layer structure and interface composition of Al/PTFE multilayers was analysed by transmission electron microscope and X-ray photoelectron spectroscopy, respectively. The heat release reaction in Al/PTFE multilayers can be triggered with reaction temperature of 430 °C, and the overall heat of reaction is 3192 J/g. Al/PTFE multilayers with bilayer thickness of 200 nm was alternately deposited on a Cu film bridge to improve the electric explosion performances. Compared to Cu film bridge, the Al/PTFE/Cu integrated film bridge exhibits improved performances with longer explosion duration time, more violent explosion phenomenon and larger quantities of ejected product particles.
NASA Technical Reports Server (NTRS)
Wingard, Doug
2010-01-01
Human urine and flush water are eventually converted into drinking water with the Urine Processor Assembly (UPA) aboard the International Space Station (ISS). This conversion is made possible through the Distillation Assembly (DA) of the UPA. One component of the DA is a molded circular piston cup made of virgin polytetrafluoroethylene (PTFE). The piston cup is assembled to a titanium component using eight fasteners and washers. Molded PTFE produced for spare piston cups in the first quarter of 2010 was different in appearance and texture, and softer than material molded for previous cups. For the suspect newer PTFE material, cup fasteners were tightened to only one-half the required torque value, yet the washers embedded almost halfway into the material. The molded PTFE used in the DA piston cup should be Type II, based on AMS 3667D and ASTM D4894 specifications. The properties of molded PTFE are considerably different between Type I and II materials. Engineers working with the DA thought that if Type I PTFE was molded by mistake instead of Type II material, that could have resulted in the anomalous material properties. Typically, the vendor molds flat sheet PTFE from the same material lot used to mold the piston cups, and tensile testing as part of quality control should verify that the PTFE is Type II material. However, for this discrepant lot of material, such tensile data was not available. Differential scanning calorimetry (DSC) and dynamic mechanical analysis (DMA) were two of the testing techniques used at the NASA/Marshall Space Flight Center (MSFC) to investigate the anomaly for the PTFE material. Other techniques used on PTFE specimens were: Shore D hardness testing, tensile testing on dog bone specimens and a qualitative estimation of porosity by optical and scanning electron microscopy.
Riga, Celia V; Bicknell, Colin D; Basra, Melvinder; Hamady, Mohamad; Cheshire, Nicholas J W
2013-08-01
To investigate the quality of stent-graft fenestrations created in vitro using different needle puncture and balloon dilation angles in different commercial endografts. Fenestrations were made in a standardized fashion in 3 different endograft types: Talent monofilament twill woven polyester, Zenith multifilament tubular woven polyester, and Endofit thin-walled expanded polytetrafluoroethylene (PTFE). Punctures were made at 30°, 60°, and 90° angles using a 20-G needle and dilated using 6-mm standard and 7-mm cutting balloons; at least 6 fenestrations were made at each angle with standard balloons and at least 6 with cutting balloons. The 137 fenestrations were examined under light microscopy; quantitative and qualitative digital image analysis was performed to determine size, shape, and fenestration quality. PTFE grafts were easier to puncture/dilate, resulting in larger, elliptical fenestrations with overall better quality than the Dacron grafts; however, the puncture/dilation angle made an impact on the shape and quality of fenestrations. A significant number of fabric tears were observed in PTFE fabric at <90° puncture/dilation angles compared to Dacron grafts. In Dacron grafts, fenestration quality was significantly higher with 90° puncture/dilation angles (higher in Talent grafts). Cutting balloon use resulted in significantly more fabric tears and poor quality fenestrations in all graft types. Different endografts behave significantly differently when fenestrations are fashioned. Optimum puncture/dilation is important when considering in vivo fenestration techniques. Improvements in instrumentation, materials, and techniques are required to make this a reliable and reproducible endovascular option.
XPS analysis of the effect of fillers on PTFE transfer film development in sliding contacts
NASA Technical Reports Server (NTRS)
Blanchet, T. A.; Kennedy, F. E.; Jayne, D. T.
1993-01-01
The development of transfer films atop steel counterfaces in contact with unfilled and bronze-filled PTFE has been studied using X-ray photoelectron spectroscopy. The sliding apparatus was contained within the vacuum of the analytical system, so the effects of the native oxide, hydrocarbon, and adsorbed gaseous surface layers of the steel upon the PTFE transfer behavior could be studied in situ. For both the filled and the unfilled PTFE, cleaner surfaces promoted greater amounts of transfer. Metal fluorides, which formed at the transfer film/counterface interface, were found solely in cases where the native oxide had been removed to expose the metallic surface prior to sliding. These fluorides also were found at clean metal/PTFE interfaces formed in the absence of frictional contact. A fraction of these fluorides resulted from irradiation damage inherent in XPS analysis. PTFE transfer films were found to build up with repeated sliding passes, by a process in which strands of transfer filled in the remaining counterface area. Under these reported test conditions, the transfer process is not expected to continue atop previously deposited transfer films. The bronze-filled composite generated greater amounts of transfer than the unfilled PTFE. The results are discussed relative to the observed increase in wear resistance imparted to PTFE by a broad range of inorganic fillers.
Adhesion between polymers and evaporated gold and nickel films
NASA Technical Reports Server (NTRS)
Yamada, Y.; Wheeler, D. R.; Buckley, D. H.
1984-01-01
To obtain information on the adhesion between metal films and polymeric solids, the adhesion force was measured by means of a tensile pull test. It was found that the adhesion strengths between polymeric solids and gold films evaporated on polymer substrates were (1.11 + or - 0.53) multiplied by 10(6) N/M(2) on PTFE, about 5.49 multiplied by 10(6) N/m(2) on UHMWPE, and 6.54x10(6) on 6/6 nylon. The adhesion strengths for nickel films evaporated on PTFE, UHMWPE, and 6/6 nylon were found to be a factor of 1.7 higher than those for the gold coated PTFE, UHMWPE, and 6/6 nylon. To confirm quantitatively the effect of electron irradiation on the adhesion strength between a PTFE solid and metal films, a tensile pull test was performed on the irradiated PTFE specimens, which were prepared by evaporating nickel or gold on PTFE surfaces irradiated by 2-keV electrons for various times. After irradiation, the adhesion strength increased to (4.92 + or - 0.92)x10(6) N/m(2) for nickel coated PTFE and (1.82 + or - 0.48)x10(6) N/m(2) for gold coated PTFE. The improvement in adhesion for nickel is higher than that for gold.
Temperature-Dependent Friction and Wear Behavior of PTFE and MoS 2
DOE Office of Scientific and Technical Information (OSTI.GOV)
Babuska, T. F.; Pitenis, A. A.; Jones, M. R.
2016-06-16
We present an investigation of the temperature-dependent friction behavior of PTFE, MoS 2, and PTFE-on- MoS 2. Friction behavior was measured while continuously varying contact temperature in the range -150 to 175°C while sliding in dry nitrogen, as well as for self-mated PTFE immersed in liquid nitrogen. These results contrast with previous reports of monotonic inverse temperature dependent friction behavior, as well as reported high-friction transitions and plateaus at temperatures below about -20°C that were not observed, providing new insights about the molecular mechanisms of macro-scale friction. The temperature-dependent friction behavior characteristic of self-mated PTFE was found also on themore » PTFE-on-MoS 2 sliding contact, suggesting that PTFE friction was defined by sub-surface deformation mechanisms and internal friction even when sliding against a lamellar lubricant with extremely low friction coefficient (μ ~ 0.02). The various relaxation temperatures of PTFE were found in the temperature-dependent friction behavior, showing excellent agreement with reported values acquired using torsional techniques measuring internal friction. Additionally, hysteresis in friction behavior suggests an increase in near-surface crystallinity at upon exceeding the high temperature relaxation, T α~ 116°C.« less
Improved conductivity of carbon-nano-fiber (CNF)/polytetrafluoroethylene (PTFE) composite
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chandra, Sarita; Kalra, G. S.; Pushkar, Vinay K.
2016-05-23
A series of CNF/PTFE composite loaded with different weight % of CNFs as 0.01, 0.02, 0.03, 0.05, 1, 2, 3, 4, 5 into PTFE is fabricated. In this work, the 5wt% heat-treated CNFs were used as filler in PTFE. Current-voltage (I-V) study of the samples confirmed the samples as conducting composite. In scanning electron microscope (SEM) study, the conducting CNFs channels were observed from upper surface to inside throughout the polymer matrix. A sintered composite of 5 wt% loading of CNFs showed an improved conductivity and SEM image exhibited a good binding of CNFs into PTFE.
Adhesion and transfer of PTFE to metals studied by auger emission spectroscopy
NASA Technical Reports Server (NTRS)
Pepper, S. V.; Buckley, D. H.
1972-01-01
The adhesion and transfer of polytetrafluoroethylene (PTFE) to metals in ultrahigh vacuum has been studied using Auger emission spectroscopy. The transfer was effected both by compressive static contact and by sliding contact. The transfer observed after static contact was independent of the chemical constitution of the substrate. Electron induced desorption of the fluorine in the transferred PTFE showed that the fluorine had no chemical interaction with the metal substrate. The coefficient of friction on metals was independent of the chemical constitution of the substrate. However, sliding PTFE on soft metals such as aluminum, generated wear fragments that lodged in the PTFE and machined the substrate.
Study of Abrasive Wear Volume Map for PTFE and PTFE Composites
NASA Astrophysics Data System (ADS)
Unal, H.; Sen, U.; Mimaroglu, A.
2007-11-01
The potential of this work is based on consideration of wear volume map for the evaluation of abrasive wear performance of polytetrafluoroethylene (PTFE) and PTFE composites. The fillers used in the composite are 25% bronze, 35% graphite and 17% glass fibre glass (GFR). The influence of filler materials, abrasion surface roughness and applied load values on abrasive wear performance of PTFE and PTFE composites were studied and evaluated. Experimental abrasive wear tests were carried out at atmospheric condition on pin-on-disc wear tribometer. Tests were performed under 4, 6, 8 and 10 N load values, travelling speed of 1 m/sec and abrasion surface roughness values of 5, 20 and 45 µm. Wear volume maps were obtained and the results showed that the lowest wear volume rate for PTFE is reached using GFR filler. Furthermore, the results also showed that the higher is the applied load and the roughness of the abrasion surface, the higher is the wear rate. Finally it is also concluded that abrasive wear process mechanism include ploughing and cutting mechanisms.
NASA Astrophysics Data System (ADS)
Lan, Yan; You, Qingliang; Cheng, Cheng; Zhang, Suzhen; Ni, Guohua; Nagatsu, M.; Meng, Yuedong
2011-02-01
Surface modification on a polytetrafluoroethylene (PTFE) panel was performed with sequential nitrogen plasma treatments and surface-initiated polymerization. By introducing COO- groups to the surface of the PTFE panel through grafting polymerization of acrylic acid (AA), a transparent poly (acrylic acid) (PAA) membrane was achieved from acrylic acid solution. Grafting polymerization initiating from the active groups was achieved on the PTFE panel surface after the nitrogen plasma treatment. Utilizing the acrylic acid as monomers, with COO- groups as cross link sites to form reticulation structure, a transparent poly (acrylic acid) membrane with arborescent macromolecular structure was formed on the PTFE panel surface. Analysis methods, such as fourier transform infrared spectroscopy (FTIR), microscopy and X-ray photoelectron spectroscopy (XPS), were utilized to characterize the structures of the macromolecule membrane on the PTFE panel surface. A contact angle measurement was performed to characterize the modified PTFE panels. The surface hydrophilicities of modified PTFE panels were significantly enhanced after the plasma treatment. It was shown that the grafting rate is related to the treating time and the power of plasma.
Covered stent graft for treatment of a pseudoaneurysm and carotid blowout syndrome
Janjua, Nazli; Alkawi, Ammar; Georgiadis, Alexandros L.; Kirmani, Jawad F.; Qureshi, Adnan I.
2008-01-01
Background Carotid blowout syndrome with pseudoaneurysm, a rapidly progressive pathology, may present emergently with massive oral hemorrhage. Use of an endograft prosthesis offers a treatment strategy with salvation of the carotid artery. Case History: A 55 year old man with advanced squamous cell carcinoma of the head and neck presented with recurrent transoral hemorrhage, requiring endovascular treatment. Technical Report: Coil embolization was initially performed with little impact on the hemorrhage. A 7 x 40 mm Fluency® Plus covered stent (Bard Peripheral Vascular, Tempe, Arizona, USA) was placed and was supplemented by a second 8 x 40 mm Fluency Plus stent, with resulting cessation of active contrast extravasation. Discussion: The risks and benefits of various treatment options of carotid pseudoaneurysm with blowout are discussed including the use or omission of antiplatelet and anticoagulant regimens, with reference to previously reported cases. Conclusion: Tandem, overlapping covered stent placement in the common carotid artery is feasible and offers a treatment option for carotid blowout syndrome. Risks of aggravation of hemorrhage versus long-term thromboembolic events without antiplatelet therapy must be considered in cases of active ongoing hemorrhage. PMID:22518207
NASA Technical Reports Server (NTRS)
Wheeler, Donald R.; Pepper, Stephen V.
1990-01-01
Polytetrafluoroethylene (PTFE) was subjected to 3 keV electron bombardment and then heated in vacuum to 300 C. The behavior of the material as a function of radiation dose and temperature was studied by X-ray photoelectron spectroscopy (XPS) of the surface and mass spectroscopy of the species evolved. Lightly damaged material heated to 300 C evolved saturated fluorocarbon species, whereas unsaturated fluorocarbon species were evolved from heavily damaged material. After heating the heavily damaged material, those features in the XPS spectrum that were associated with damage diminished, giving the appearance that the radiation damage had annealed. The observations were interpreted by incorporating mass transport of severed chain fragments and thermal decomposition of severely damaged material into the branched and cross-linked network model of irradiated PTFE. The apparent annealing of the radiation damage was due to covering of the network by saturated fragments that easily diffused through the decomposed material to the surface region upon heating.
Evaluation of tissue interactions with mechanical elements of a transscleral drug delivery device.
Cohen, Sarah J; Chan, Robison V Paul; Keegan, Mark; Andreoli, Christopher M; Borenstein, Jeffrey T; Miller, Joan W; Gragoudas, Evangelos S
2012-03-12
The goal of this work was to evaluate tissue-device interactions due to implantation of a mechanically operated drug delivery system onto the posterior sclera. Two test devices were designed and fabricated to model elements of the drug delivery device-one containing a free-spinning ball bearing and the other encasing two articulating gears. Openings in the base of test devices modeled ports for drug passage from device to sclera. Porous poly(tetrafluoroethylene) (PTFE) membranes were attached to half of the gear devices to minimize tissue ingrowth through these ports. Test devices were sutured onto rabbit eyes for 10 weeks. Tissue-device interactions were evaluated histologically and mechanically after removal to determine effects on device function and changes in surrounding tissue. Test devices were generally well-tolerated during residence in the animal. All devices encouraged fibrous tissue formation between the sclera and the device, fibrous tissue encapsulation and invasion around the device, and inflammation of the conjunctiva. Gear devices encouraged significantly greater inflammation in all cases and a larger rate of tissue ingrowth. PTFE membranes prevented tissue invasion through the covered drug ports, though tissue migrated in through other smaller openings. The torque required to turn the mechanical elements increased over 1000 times for gear devices, but only on the order of 100 times for membrane-covered gear devices and less than 100 times for ball bearing devices. Maintaining a lower device profile, minimizing microscale motion on the eye surface and covering drug ports with a porous membrane may minimize inflammation, decreasing the risk of damage to surrounding tissues and minimizing disruption of device operation.
Higuchi, Masatoshi; Moroi, Akinori; Yoshizawa, Kunio; Kosaka, Akihiko; Ikawa, Hiroumi; Iguchi, Ran; Saida, Yuriko; Hotta, Asami; Tsutsui, Takamitsu; Ueki, Koichiro
2016-09-01
The purpose of this study was to compare bone regenerative capability following use of polytetrafluoroethylene (ePTFE) membrane against that when various densities of pore titanium meshes are used with and without low intensity pulsed ultrasound (LIPUS). Adult male white rabbits were divided into 8 groups. In 4 groups, after incising along the nasal bone, four 3 × 8 mm bone defects were made in both sides and covered by an ePTFE membrane (group E: n = 15), a high density pore titanium mesh (group H: n = 15), a low density pore titanium mesh (group L: n = 15), and no mesh (control) (group C: n = 15). Furthermore, LIPUS was irradiated after surgery in 4 groups (groups EL, HL, LL and CL, in each n = 15). The rabbits were sacrificed at 1, 2 and 8 weeks postoperative, and formalin-fixed specimens were embedded in acrylic resin. The specimens were stained with hematoxylin and eosin. For immunohistochemical analysis, the specimens were treated with bone morphogenetic protein (BMP)-2 antibody. Group H had significantly higher values than groups L, E, and C regarding bone area ratio and labeling index of BMP-2 positive cells (P < 0.05). Furthermore, Group HL also had significantly higher values than the other groups regarding bone area ratio and labeling index of BMP-2 positive cells at 1, 2 and 8 weeks postoperative (P < 0.05). The results suggested that high density pore titanium mesh could induce new bone regeneration more than low density pore titanium mesh and ePTFE membrane. New bone formation may increase following LIPUS application. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Freeman, John; Chen, Aaron; Weinberg, Roy J; Okada, Tamuru; Chen, Changyi; Lin, Peter H
2018-05-01
Bypass graft thrombosis remains a significant mode of failure in prosthetic graft revascularization. The purpose of this investigation was to evaluate the long-term thromboresistant effect of heparin-bonded expanded polytetrafluoroethylene (ePTFE) graft using Carmeda BioActive Surface technology in a canine model. Bilateral femorofemoral artery bypass grafts with ePTFE grafts were performed in 25 adult grayhound dogs. In each animal, a heparin-bonded ePTFE graft (Propaten, WL Gore) was placed on one side, whereas a control nonheparin graft was placed on the contralateral side. The graft patency was assessed at 1, 6, 12, 18, and 24 months (n = 5 per group) following the bypass. Heparin bioactivity of the graft material was analyzed. The effect of intimal hyperplasia was also assessed. All bypass grafts were patent at 1 month. Significantly greater patency rates were noted in the Propaten group compared to the control group at 12, 18, and 24 months, which were 84%, 80%, and 80% vs. 55%, 35%, and 20%, respectively (P < 0.02). There was a significant reduction in the anastomotic neointimal area and neointimal cell proliferation in Propaten grafts compared with control grafts at all groups between 6 and 24 months (P < 0.05). Heparin bioactivity as measured by antithrombin binding assay was demonstrated in the Propaten graft between 1 and 24 months. Mean heparin activities on Propaten grafts ranged from 26.3 ± 6.4 pmol/cm 2 to 18.4 ± 8.7 pmol/cm 2 between 1 and 24 months, which were significantly greater than the control group (P < 0.001). Differences between mean heparin activities of explanted Propaten graft samples at the various time points were nonsignificant (P > 0.05). Heparin-bonded ePTFE graft provides a thromboresistant surface and reduced anastomotic intimal hyperplasia at 2 years. The stable heparin bioactivity of the Propaten graft confers an advantage in long-term graft patency. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.
Dynamic bioactive stimuli-responsive polymeric surfaces
NASA Astrophysics Data System (ADS)
Pearson, Heather Marie
This dissertation focuses on the design, synthesis, and development of antimicrobial and anticoagulant surfaces of polyethylene (PE), polypropylene (PP), and poly(tetrafluoroethylene) (PTFE) polymers. Aliphatic polymeric surfaces of PE and PP polymers functionalized using click chemistry reactions by the attachment of --COOH groups via microwave plasma reactions followed by functionalization with alkyne moieties. Azide containing ampicillin (AMP) was synthesized and subsequently clicked into the alkyne prepared PE and PP surfaces. Compared to non-functionalized PP and PE surfaces, the AMP clicked surfaces exhibited substantially enhanced antimicrobial activity against Staphylococcus aureus bacteria. To expand the biocompatibility of polymeric surface anticoagulant attributes, PE and PTFE surfaces were functionalized with pH-responsive poly(2-vinyl pyridine) (P2VP) and poly(acrylic acid) (PAA) polyelectrolyte tethers terminated with NH2 and COOH groups. The goal of these studies was to develop switchable stimuli-responsive polymeric surfaces that interact with biological environments and display simultaneous antimicrobial and anticoagulant properties. Antimicrobial AMP was covalently attached to --COOH terminal ends of protected PAA, while anticoagulant heparin (HEP) was attached to terminal --NH2 groups of P2VP. When pH < 2.3, the P2VP segments are protonated and extend, but for pH > 5.5, they collapse while the PAA segments extend. Such surfaces, when exposed to Staphylococcus aureus, inhibit bacterial growth due to the presence of AMP, as well as are effective anticoagulants due to the presence of covalently attached HEP. Comparison of these "dynamic" pH responsive surfaces with "static" surfaces terminated with AMP entities show significant enhancement of longevity and surface activity against microbial film formation. The last portion of this dissertation focuses on the covalent attachment of living T1 and Φ11 bacteriophages (phages) on PE and PTFE surface. This was accomplished by carbodiimide coupling between --COOH groups on PE and PTFE surfaces and --NH2 moieties present on T1 and Φ11 phages. These studies show that covalently attached T1 and Φ11 phages retain their antimicrobial activity manifested by the effective destruction of both Gram negative Escherichia coli (Φ11) phages and Gram positive Staphylococcus aureus bacteria (T1).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Selvakumar, N.; Barshilia, Harish C.; Rajam, K. S.
2010-07-15
We have studied the effect of substrate roughness on the wettability and the apparent surface free energy (SFE) of sputter deposited polytetrafluoroethylene (PTFE) coatings deposited on untreated glass (average roughness, R{sub a}=2.0 nm), plasma etched glass (R{sub a}=7.4 nm), and sandblasted glass (R{sub a}=4500 nm) substrates. The wettability of the PTFE coatings deposited on substrates with varying roughnesses was evaluated by measuring the apparent contact angle (CA) using a series of probe liquids from nonpolar aprotic to polar protic. The wettability measurements indicate that an apparent water CA of 152 deg. with a sliding angle of 8 deg. was achievedmore » for PTFE coatings deposited on a substrate with R{sub a}=4500 nm. The superhydrophobicity observed in these coatings is attributed to the presence of dual scale roughness, densely packed microstructure and the presence of CF{sub 3} groups. Unlike the bulk PTFE which is mainly dispersive, the sputter deposited PTFE coatings are expected to have some degree of polar component due to the plasma treatment. In order to calculate the dispersive SFE of PTFE coatings, we have used the Girifalco-Good-Fowkes (GGF) method and validated it with the Zisman model. Furthermore, the Owens-Wendt model has been used to calculate the dispersive and the polar components of the apparent SFE of the PTFE coatings. These results are further corroborated using the Fowkes method. Finally, an ''equation of state'' theory proposed by Neumann has been used to calculate the apparent SFE values of the PTFE coatings. The results indicate that the apparent SFE values of the PTFE coatings obtained from the Owens-Wendt and the Fowkes methods are comparable to those obtained from the Neumann's method. The analyses further demonstrate that the GGF and the Zisman methods underestimate the apparent SFE values of the sputter deposited PTFE coatings.« less
Zhu, Youbing; Yu, Shuili; Zhang, Bing; Li, Jianfeng; Zhao, Dongsheng; Gu, Zhengyang; Gong, Chao; Liu, Guicai
2018-06-18
Alkali/surfactant/polymer (ASP) flooding wastewater is highly caustic, and membrane fouling is the main obstacle during ASP ultrafiltration (UF) treatment. To maintain favorable filtration performance, polytetrafluoroethylene (PTFE) and polyvinylidene fluoride (PVDF) membranes were implemented here, and their antifouling properties and mechanisms were investigated based on the threshold flux theory. Compared with the PVDF membranes, the PTFE membranes exhibited superior antifouling properties with lower reductions in flux and smaller hydraulic resistance, and they presented a nearly identical pseudo-stable fouling rate at a later time point. In the fouling layers of the PTFE and PVDF membranes, anion polyacrylamide (APAM) was observed along with divalent/trivalent metal ions. The thermodynamic and molecular mechanisms of membrane fouling by APAM were elucidated using the Extended Derjaguin-Landau-Verwey-Overbeek (XDLVO) theory and atomic force microscopy (AFM), respectively. The calculated total interfacial free energy (mJ/m 2 ) of adhesion between the APAM and PTFE membranes was positive, and the value between the APAM and PVDF membranes was negative. Furthermore, the values and interaction distances of the measured intermolecular rupture and approaching forces were larger for APAM-PTFE than for APAM-PVDF. For the PTFE membranes, the positive free energies and smaller intermolecular interaction resulted in weaker APAM-PTFE adhesion and adsorption and therefore the lower levels of flux decline and the later achievement of the pseudo-stable fouling rate. Additionally, the total flux recoveries observed after physical cleaning reached 0.78-0.80 and 0.32-0.39 for the PTFE and PVDF membranes, respectively, which showed that the PTFE membranes can be cleaned easily. The PTFE membranes have considerable potential for extensive application in UF treatments for ASP wastewater. These results should promote understanding the essence of the threshold flux and the fouling control of UF membranes. Copyright © 2018. Published by Elsevier B.V.
Blast Coating of Superelastic NiTi Wire with PTFE to Enhance Wear Properties
NASA Astrophysics Data System (ADS)
Dunne, Conor F.; Roche, Kevin; Twomey, Barry; Hodgson, Darel; Stanton, Kenneth T.
2015-03-01
This work investigates the deposition of polytetrafluoroethylene (PTFE) onto a superelastic NiTi wire using an ambient temperature-coating technique known as CoBlast. The process utilises a stream of abrasive (Al2O3) and a coating medium (PTFE) sprayed simultaneously at the surface of the substrate. Superelastic NiTi wire is used in guidewire applications, and PTFE coatings are commonly applied to reduce damage to vessel walls during insertion and removal, and to aid in accurate positioning by minimising the force required to advance, retract or rotate the wire. The CoBlast coated wires were compared to wire treated with PTFE only. The coated samples were examined using variety of techniques: X-ray diffraction (XRD), microscopy, surface roughness, wear testing and flexural tests. The CoBlast coated samples had an adherent coating with a significant resistance to wear compared to the samples coated with PTFE only. The XRD revealed that the process gave rise to a stress-induced martensite phase in the NiTi which may enhance mechanical properties. The study indicates that the CoBlast process can be used to deposit thin adherent coatings of PTFE onto the surface of superelastic NiTi.
Pulse electrodeposition of self-lubricating Ni-W/PTFE nanocomposite coatings on mild steel surface
NASA Astrophysics Data System (ADS)
Sangeetha, S.; Kalaignan, G. Paruthimal; Anthuvan, J. Tennis
2015-12-01
Ni-W/PTFE nanocomposite coatings with various contents of PTFE (polytetafluoroethylene) particles were prepared by pulse current (PC) electrodeposition from the Ni-W plating bath containing self lubricant PTFE particles to be co-deposited. Co-deposited PTFE particulates were uniformly distributed in the Ni-W alloy matrix. The coatings were characterized by Scanning Electron Microscopy (SEM), Energy Dispersive X-Ray Analysis (EDAX), X-ray Diffractometry (XRD) and Vicker's micro hardness tester. Tafel Polarization and electrochemical Impedance methods were used to evaluate the corrosion resistance behaviour of the nanocomposite coatings in 3.5% NaCl solution. It was found that, the Ni-W/PTFE nanocomposite coating has better corrosion resistance than the Ni-W alloy coating. Surface roughness and friction coefficient of the coated samples were assessed by Mitutoyo Surftest SJ-310 (ISO1997) and Scratch tester TR-101-M4 respectively. The contact angle (CA) of a water droplet on the surface of nanocomposite coating was measured by Optical Contact Goniometry (OCA 35). These results indicated that, the addition of PTFE in the Ni-W alloy matrix has resulted moderate microhardness, smooth surface, less friction coefficient, excellent water repellency and enhanced corrosion resistance of the nanocomposite coatings.
Method of radiation degradation of PTFE under vacuum conditions
NASA Astrophysics Data System (ADS)
Korenev, Sergey
2004-09-01
A new method of radiation degradation of Polytetrafluoroethylene (PTFE) under vacuum conditions is considered in this report. The combination of glow gas discharge and electrical surface discharge (on surface and inside PTFE) increases the efficiency of thermal-radiation degradation. The main mechanism of this degradation method consists of the breaking of C-C and C-F bonds. The vacuum conditions allow decreasing of the concentration of toxic compounds, such as a HF. Experimental results for degradation of PTFE are presented.
NASA Astrophysics Data System (ADS)
Ito, Hiroshi; Iwamura, Takuya; Someya, Satoshi; Munakata, Tetsuo; Nakano, Akihiro; Heo, Yun; Ishida, Masayoshi; Nakajima, Hironori; Kitahara, Tatsumi
2016-02-01
This experimental study identifies the effect of through-plane polytetrafluoroethylene (PTFE) distribution in gas diffusion backing (GDB) on the performance of proton exchange membrane fuel cells (PEMFC). PTFE-drying under vacuum pressure created a relatively uniform PTFE distribution in GDB compared to drying under atmospheric pressure. Carbon paper samples with different PTFE distributions due to the difference in drying conditions were prepared and used for the cathode gas diffusion layer (GDL) of PEMFCs. Also investigated is the effect of MPL application on the performance for those samples. The current density (i) - voltage (V) characteristics of these PEMFCs measured under high relative humidity conditions clearly showed that, with or without MPL, the cell using the GDL with PTFE dried under vacuum condition showed better performance than that dried under atmospheric condition. It is suggested that this improved performance is caused by the efficient transport of liquid water through the GDB due to the uniform distribution of PTFE.
Gallyamov, Marat O; Qin, Shuhui; Matyjaszewski, Krzysztof; Khokhlov, Alexei; Möller, Martin
2009-07-21
Using SFM we have observed a peculiar twisting motion of diblock macromolecules pre-collapsed in ethanol vapour during their subsequent spreading in water vapour. The intrinsic asymmetry of the diblock macromolecules has been considered to be the reason for such twisting. Further, friction-deposited PTFE nano-stripes have been employed as nano-trails with the purpose of inducing lateral directed motion of the asymmetric diblock macromolecules under cyclic impact from the changing vapour surroundings. Indeed, some of the macromolecules have demonstrated a certain tendency to orient along the PTFE stripes, and some of the oriented ones have moved occasionally in a directed manner along the trail. However, it has been difficult to reliably record such directed motion at the single molecule level due to some mobility of the PTFE nano-trails themselves in the changing vapour environment. In vapours, the PTFE stripes have demonstrated a distinct tendency towards conjunction. This tendency has manifested itself in efficient expelling of groups of the mobile brush-like molecules from the areas between two PTFE stripes joining in a zip-fastener manner. This different kind of vapour-induced cooperative macromolecular motion has been reliably observed as being directed. The PTFE nano-frame experiences some deformation when constraining the spreading macromolecules. We have estimated the possible force causing such deformation of the PTFE fence. The force has been found to be a few pN as calculated by a partial contribution from every single molecule of the constrained group.
Li, Chaojing; Wang, Fujun; Douglas, Graeham; Zhang, Ze; Guidoin, Robert; Wang, Lu
2017-05-01
Vascular grafts made by tissue engineering processes are prone to buckling and twisting, which can impede blood flow and lead to collapse of the vessel. These vascular conduits may suffer not only from insufficient tensile strength, but also from vulnerabilities related to compression, torsion, and pulsatile pressurization. Aiming to develop a tissue engineering-inspired blood conduit, composite vascular graft (cVG) prototypes were created by combining a flexible polylactic acid (PLA) knitted fabric with a soft polycaprolactone (PCL) matrix. The graft is to be populated in-situ with cellular migration and proliferation into the device. Comprehensive characterizations probed the relationship between structure and mechanical properties of the different cVG prototypes. The composite grafts exhibited major improvements in mechanical characteristics compared to single-material devices, with particular improvement in compression and torsional resistance. A commercial expanded polytetrafluoroethylene (ePTFE) vascular graft was used as a control against the proposed composite vascular grafts. CVG devices showed high tensile strength, high bursting strength, and improved suture retention. Compression, elastic recovery, and compliance were similar to those for the ePTFE graft. Copyright © 2016 Elsevier Ltd. All rights reserved.
Computed tomographic assessment of the causal factors of unsuccessful medialization thyroplasty.
Iwahashi, Toshihiko; Ogawa, Makoto; Hosokawa, Kiyohito; Mochizuki, Ryuichi; Inohara, Hidenori
2015-03-01
The present results demonstrate that a small implant size, undercorrection of the vocal fold, antero-posterior implant malposition, and the use of expanded polytetrafluoroethylene (ePTFE) are the primary factors that cause a poor outcome of medialization thyroplasty (MT). To assess the postoperative laryngeal condition using computed tomography (CT) in patients with unilateral vocal fold paralysis who underwent MT alone, and to identify the primary causal factors in terms of the surgical procedures that affect the outcomes of MT. Twenty-two patients who underwent MT alone were divided into two groups based on either the maximal phonation time or the perceived vocal breathiness. Two laryngologists assessed the postoperative laryngeal CT images during sustained vowel phonation and judged whether there were abnormalities of the arytenoid cartilage position, window position, implant size, and implant position, as well as the degree of correction of the vocal fold. As implant material, a silicone block, ePTFE, and hydroxyapatite had been inserted in 2, 9, and 11 patients, respectively. Comparisons of the prevalence of abnormalities in the abovementioned factors between the different outcomes and between the types of material used for the implant were performed. Twelve patients with a poor outcome and 10 with a good outcome showed 36 and 18 abnormal findings identified by either of the two laryngologists, respectively. In the poor outcome group, a smaller implant size and undercorrection of the vocal fold showed both high kappa values and a significantly higher prevalence than those in the good outcome group (p < 0.001 and p < 0.05), respectively. The comparison between material types demonstrated that the sheet-like material (ePTFE) group exhibited a significantly higher prevalence of undercorrection than the block-like material group (p < 0.05).
Management of sepsis involving expanded polytetrafluoroethylene grafts for hemodialysis access.
Bhat, D J; Tellis, V A; Kohlberg, W I; Driscoll, B; Veith, F J
1980-04-01
The incidence and management of infections in 80 polytetrafluoroethylene (PTFE) grafts is reviewed. In a follow-up period of 12 to 30 months, the overall incidence of infection was 19%. In functioning grafts the majority of infections occurred after dialysis puncture or reoperation. With appropriate management, by incision, drainage, and packing of wounds with povidone-iodine solution, it was possible, even in the face of positive blood cultures, to treat four of five localized infections successfully without loss of graft function. Prophylactic antibiotics may be useful in reducing the high incidence of infection associated with secondary operations.
Morton, Reeva C; Gadke, Daniel L
2018-03-01
Cover, Copy, Compare (CCC) and Copy, Cover, Compare (MCCC) procedures are effective interventions for improving math fluency. However, there is a gap in literature exploring the use of these interventions for children with autism spectrum disorders (ASD). The purpose of the current study was to compare the use of CCC and MCCC for children with ASD using a multi-component single-case experimental design. The results showed no notable difference between the interventions. Implications and limitations, particularly surrounding experimental control, are discussed in detail.
NASA Astrophysics Data System (ADS)
Mortazavi, Mehdi; Tajiri, Kazuya
2014-01-01
The dynamic behavior of a liquid water droplet emerging and detaching from the surface of the gas diffusion layer (GDL) is investigated. The droplet growth and detachment are studied for different polytetrafluoroethylene (PTFE) contents within the GDL and for different superficial gas velocities flowing in the gas channel. To simulate the droplet behavior in the cathode and anode of an operating polymer electrolyte fuel cell, separate experiments are conducted with air and hydrogen being supplied in the gas channel, respectively. Both the superficial gas velocity and the PTFE content within the GDL are found to impact the droplet detachment diameter. Increasing the superficial gas velocity increases the drag force applied on the droplet sitting on the GDL surface. It is observed that the droplet detaches at a smaller diameter for higher superficial gas velocities. The droplets also detach at smaller diameters from GDLs with a higher amount of PTFE. Such observation is justified according to two different points of view: (1) heterogeneous through-plane PTFE distribution through the GDL and (2) reduced GDL surface roughness caused by PTFE loading.
Adhesion and removal kinetics of Bacillus cereus biofilms on Ni-PTFE modified stainless steel.
Huang, Kang; McLandsborough, Lynne A; Goddard, Julie M
2016-01-01
Biofilm control remains a challenge to food safety. A well-studied non-fouling coating involves codeposition of polytetrafluoroethylene (PTFE) during electroless plating. This coating has been reported to reduce foulant build-up during pasteurization, but opportunities remain in demonstrating its efficacy in inhibiting biofilm formation. Herein, the initial adhesion, biofilm formation, and removal kinetics of Bacillus cereus on Ni-PTFE-modified stainless steel (SS) are characterized. Coatings lowered the surface energy of SS and reduced biofilm formation by > 2 log CFU cm(-2). Characterization of the kinetics of biofilm removal during cleaning demonstrated improved cleanability on the Ni-PTFE coated steel. There was no evidence of biofilm after cleaning by either solution on the Ni-PTFE coated steel, whereas more than 3 log and 1 log CFU cm(-2) of bacteria remained on the native steel after cleaning with water and an alkaline cleaner, respectively. This work demonstrates the potential application of Ni-PTFE non-fouling coatings on SS to improve food safety by reducing biofilm formation and improving the cleaning efficiency of food processing equipment.
Deposition of PTFE thin films by ion beam sputtering and a study of the ion bombardment effect
NASA Astrophysics Data System (ADS)
He, J. L.; Li, W. Z.; Wang, L. D.; Wang, J.; Li, H. D.
1998-02-01
Ion beam sputtering technique was employed to prepare thin films of Polytetrafluroethylene (PTFE). Simultaneous ion beam bombardment during film growth was also conducted in order to study the bombardment effects. Infrared absorption (IR), X-ray photoelectron spectroscopy (XPS) and X-ray diffraction (XRD) analysis was used to evaluate the material's integrity. It was found that PTFE thin films could be grown at room temperature by direct sputtering of a PTFE target. The film's composition and structure were shown to be dependent on the sputtering energy. Films deposited by single sputtering at higher energy (˜1500 eV) were structurally quite similar to the original PTFE material. Simultaneous ion beam bombarding during film growth caused defluorination and structural changes. Mechanism for sputtering deposition of such a polymeric material is also discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dooraghi, A. A.; Seetho, I.; Smith, J.. A.
2017-04-27
In this document, we outline an experiment performed at LLNL to evaluate the radiation sensitivity of polytetrafluoroethylene (PTFE) and a PTFE isomer, fluorinated ethylene propylene (FEP). We demonstrate that PTFE, a material currently used for assessing MicroCT system stability, shows higher radiation-dependent change in x-ray attenuation than FEP. Specifically, for a dose of approximately 1.44 x 10 3 Gy, the linear attenuation coefficient (LAC) of PTFE changes by 0.8 ± 0.1 %. During the same irradiation period, the LAC for FEP changes by 0.02 ± 0.1 %, which is within the statistical uncertainty of the measurement. Due to its highermore » resistance to radiation damage, we recommend that LLNL and partner labs operating under the Department of Homeland Security’s Explosives Division (DHS EXD) transition to the use of FEP as a reference material in place of PTFE.« less
Evaluation of Tissue Interactions with Mechanical Elements of a Transscleral Drug Delivery Device
Cohen, Sarah J.; Chan, Robison V. Paul; Keegan, Mark; Andreoli, Christopher M.; Borenstein, Jeffrey T.; Miller, Joan W.; Gragoudas, Evangelos S.
2012-01-01
The goal of this work was to evaluate tissue-device interactions due to implantation of a mechanically operated drug delivery system onto the posterior sclera. Two test devices were designed and fabricated to model elements of the drug delivery device—one containing a free-spinning ball bearing and the other encasing two articulating gears. Openings in the base of test devices modeled ports for drug passage from device to sclera. Porous poly(tetrafluoroethylene) (PTFE) membranes were attached to half of the gear devices to minimize tissue ingrowth through these ports. Test devices were sutured onto rabbit eyes for 10 weeks. Tissue-device interactions were evaluated histologically and mechanically after removal to determine effects on device function and changes in surrounding tissue. Test devices were generally well-tolerated during residence in the animal. All devices encouraged fibrous tissue formation between the sclera and the device, fibrous tissue encapsulation and invasion around the device, and inflammation of the conjunctiva. Gear devices encouraged significantly greater inflammation in all cases and a larger rate of tissue ingrowth. PTFE membranes prevented tissue invasion through the covered drug ports, though tissue migrated in through other smaller openings. The torque required to turn the mechanical elements increased over 1000 times for gear devices, but only on the order of 100 times for membrane-covered gear devices and less than 100 times for ball bearing devices. Maintaining a lower device profile, minimizing microscale motion on the eye surface and covering drug ports with a porous membrane may minimize inflammation, decreasing the risk of damage to surrounding tissues and minimizing disruption of device operation. PMID:24300189
BRDF Calibration of Sintered PTFE in the SWIR
NASA Technical Reports Server (NTRS)
Georgiev, Georgi T.; Butler, James J.
2009-01-01
Satellite instruments operating in the reflective solar wavelength region often require accurate and precise determination of the Bidirectional Reflectance Distribution Function (BRDF) of laboratory-based diffusers used in their pre-flight calibrations and ground-based support of on-orbit remote sensing instruments. The Diffuser Calibration Facility at NASA's Goddard Space Flight Center is a secondary diffuser calibration standard after NEST for over two decades, providing numerous NASA projects with BRDF data in the UV, Visible and the NIR spectral regions. Currently the Diffuser Calibration Facility extended the covered spectral range from 900 nm up to 1.7 microns. The measurements were made using the existing scatterometer by replacing the Si photodiode based receiver with an InGaAs-based one. The BRDF data was recorded at normal incidence and scatter zenith angles from 10 to 60 deg. Tunable coherent light source was setup. Broadband light source application is under development. Gray-scale sintered PTFE samples were used at these first trials, illuminated with P and S polarized incident light. The results are discussed and compared to empirically generated BRDF data from simple model based on 8 deg directional/hemispherical measurements.
NASA Wiring for Space Applications Program: Fiscal year 1994 - 1995 testing activities
NASA Technical Reports Server (NTRS)
Johnson, Harry T.; Hirsch, David
1995-01-01
The results of the testing of wire insulation materials for space applications is presented in this report. The wire insulations tested were partially fluorinated polyimide, extruded ETFE, extruded PTFE, PTFE tape, and PTFE/Kapton. The tests performed were flammability tests, odor tests, compatibility tests with aerospace fluids, offgassing tests, and thermal vacuum stability tests.
NASA Wiring for Space Applications Program: Fiscal year 1994 - 1995 testing activities
NASA Astrophysics Data System (ADS)
Johnson, Harry T.; Hirsch, David
1995-11-01
The results of the testing of wire insulation materials for space applications is presented in this report. The wire insulations tested were partially fluorinated polyimide, extruded ETFE, extruded PTFE, PTFE tape, and PTFE/Kapton. The tests performed were flammability tests, odor tests, compatibility tests with aerospace fluids, offgassing tests, and thermal vacuum stability tests.
Weathering of PGE sulfides and Pt-Fe alloys in the Freetown Layered Complex, Sierra Leone
NASA Astrophysics Data System (ADS)
Bowles, John F. W.; Suárez, Saioa; Prichard, Hazel M.; Fisher, Peter C.
2017-12-01
Fresh and weathered rocks and saprolite from Horizon B of the Freetown Layered Complex contain platinum-group minerals (PGM). The PGM in the fresh rocks are 1-7 μm across, including cooperite (PtS), isoferroplatinum (Pt3Fe), minor tetraferroplatinum (PtFe), tulameenite (Pt2FeCu), Os-bearing laurite (RuS2), and other base metal-sulfide (BMS)-bearing PGM. The weathered rocks contain fewer of those PGM but a high proportion of disordered Cu-(±Pd)-bearing Pt-Fe alloys. The saprolite hosts scarce, smaller (1-3 μm) ordered PtFe and disordered PtFe3. The Pt-Fe alloys became increasingly Fe rich as weathering proceeded. Pt-Fe oxides appeared during weathering. Copper sulfides associated with the primary PGM and cooperite (with <3% Pd) were destroyed to provide the minor Cu and Pd found in some of the disordered Pt-Fe alloys. Platinum- and Pd-bearing saprolites have retained the original rock fabric and, to a depth of about 2 m, surround residual rocks that show progressive weathering (corestones). Ground water passing through the saprolite has transported Pt and Pd (and probably Au) in solution down slope into saprolite over unmineralized rocks. Transport is marked by changes in the Pt/Pd ratio indicating that the metals have moved independently. Palladium is present in marginally higher concentrations in the deeper saprolite than in the corestones suggesting some retention of Pd in the deeper saprolite. Platinum and Pd are less concentrated in the upper saprolite than the deeper saprolite indicating surface leaching. Alteration occurred over a long period in an organic and microbial rich environment that may have contributed to the leaching and transport of PGE.
Polymer/metal nanocomposite coating with antimicrobial activity against hospital isolated pathogen
NASA Astrophysics Data System (ADS)
Carvalho, D.; Sousa, T.; Morais, P. V.; Piedade, A. P.
2016-08-01
Nosocomial infections are considered an important problem in healthcare systems and are responsible for a high percentage of morbidity. Among the pathogenic microorganisms responsible for this situation Pseudomonas aeruginosa (P. aeruginosa) is consider one of the most hazardous also due to the fact that antibiotic resistant and multi-resistant organisms begin to emerge as the prevalent strains. In this work the surface of poly(tetrafluoroethylene) (PTFE) was modified by the deposition of PTFE thin films with and without silver. The hydrophobic characteristics of PTFE were attenuated by the co-deposition of PTFE and poly(amide) (PA) with and without silver. The results show that this hospital isolated bacteria is able to degrade PTFE as bulk material as well as some of the developed thin films. However, the combination of both polymer and metal induced the formation of a nanocomposite structure with antimicrobial properties against P. aeruginosa, assessed in three different biotic tests.
Scanning electron microscope study of polytetrafluoroethylene sliding on aluminum single crystals
NASA Technical Reports Server (NTRS)
Brainard, W. A.; Buckley, D. H.
1973-01-01
Friction experiments were conducted in air with polytetrafluoroethylene (PTFE) sliding on aluminum single crystals. Mechanical scoring of the crystals with (110) and (100) orientations was observed with a single pass of the PTFE slider. No scoring was observed on the (111). The degree of scoring of the crystals is related to the hardness, with the hardest surface (111) showing no damage and the softest surface (110) showing the most severe scoring. Scoring is caused by work-hardened pieces of aluminum which, as a consequence of the adhesion between PTFE and aluminum, were pulled out of the bulk and became embedded in the PTFE polymer.
Adhesion and transfer of polytetrafluorethylene to metals studied by Auger emission spectroscopy
NASA Technical Reports Server (NTRS)
Pepper, S. V.; Buckley, D. H.
1972-01-01
The adhesion and transfer of polytetrafluoroethylene (PTFE) to metals in ultrahigh vacuum were studied. The transfer was effected both by compressive static contact and by sliding contact. The transfer observed after static contact was independent of the chemical constitution of the substrate. Electron-induced desorption of the fluorine in the transferred PTFE showed that the fluorine had no chemical interaction with the metal substrate. The coefficient of friction on metals was independent of the chemical constitution of the substrate. However, sliding PTFE on soft metals, such as aluminum, generated wear fragments that lodged in the PTFE and machined the substrate.
NASA Astrophysics Data System (ADS)
Padmaraj, O.; Suthanthiraraj, S. Austin
2018-04-01
A novel stable electrospun gel polymer electrolyte [(100-x)% P(VdF-co-HFP)+(x)% P(TFE), (x = 5, 10, 15, 20, 25 & 30)/1 M Li(CF3SO2)2N-] fibrous membranes with an addition of various concentrations of hydrophobic P(TFE) polymer were prepared by an electrospinning technique. All the prepared electrospun polymer blend fibrous membranes were characterized by X-ray diffraction, Fourier transform infrared spectroscopy, differential scanning calorimetry, high resolution scanning electron microscopy techniques and water contact angle measurements. The newly developed electrospun pure and hydrophobic P(TFE) blend fibrous membranes were activated into separator-cum gel polymer electrolyte fibrous membranes by soaking in an electrolyte solution contains 1 M Li(CF3SO2)2N- in EC: PC (1:1, v/v) in an argon filled glove box. Among the various concentrations of hydrophobic P(TFE) blend polymer fibrous membranes, the electrospun gel polymer blend electrolyte with 5% P(TFE) showed low crystallinity, high thermal stability, high electrolyte uptake, good hydrophobicity and high ionic conductivity (2.680×10-2 S cm-1) at room temperature.
Bovine and PTFE vascular graft results in hemodialysis patients.
Sert, S; Demirogullari, B; Ziya Anadol, A; Guvence, N; Dalgic, A
2000-01-01
Purpose. There are many reports of patency periods, failure rates, thrombosis and infection attacks connected with vascular grafts. In this article, the results of polytetrafluoroethylene (PTFE) and Bovine grafts were compared in a forty-four month period. Methods. 61 vascular grafts (29 PTFE, 32 bovine) were placed in 49 patients. The grafts were compared in different ways, such as survival, complication rates and placement area using life survey analysis. Results. Mean survival time was 17 mo (SE +/- 2.8) for PTFE grafts and 11 mo (SE +/- 1.1) for bovine grafts. A failure rate of 34% due only to graft complications were found in PTFE and 25% in bovine grafts. All graft complications were seen in the first year. Comparison of the cumulative survival rates of the groups were found to be insignificant during the study period and the first year ( p>0.05). Regardless of the type, there was no signif-icant difference between the grafts placed in the forearm and the grafts in the thigh (p>0.05). Conclusions. There is no survival difference between PTFE and bovine grafts. First year of the grafts is important for developing complications.
NASA Astrophysics Data System (ADS)
Destyorini, Fredina; Indriyati; Indayaningsih, Nanik; Prihandoko, Bambang; Zulfia Syahrial, Anne
2018-03-01
The carbon composite papers were produced by utilizing carbon materials from coconut coir. In the present work, carbon composite papers (CCP) were prepared by mixing carbon materials in the form of powder and fibre with polymer (ethylene vinyl acetate and polyethylene glycol) in xylene at 100°C. Then, polytetrafluoroethylene (PTFE) with different content was used to treat the surface of CCP. The properties of PTFE-coated CCP were analysed by means of contact angle measurement, tensile testing, porosity, density, and electrical conductivity measurements. As expected, all CCP’s surfaces treated with PTFE were found to be hydrophobic with contact angle >120° and relatively constant during 60 minutes measurement. Furthermore, water contact angle, density, and mechanical properties of CCP generally increase with increasing PTFE content. However, the porosity and electrical conductivity of CCP decrease slightly as the PTFE content increased from 0 wt% to 30 wt%. Based on the observation and analysis, the optimum PTFE content on CCP was 20 %, in which the mechanical properties and hydrophobicity behaviour were improved significantly, but it was only caused a very small drop in porosity and electrical conductivity
Magnetorheological fluid based on thixotropic PTFE-oil organogel
NASA Astrophysics Data System (ADS)
Zhang, Hansong; Yan, Hua; Hu, Zhide; Yang, Jianjian; Niu, Fanghao
2018-04-01
Polytetrafluoroethylene (PTFE) micropowders were employed in this work to fabricate PTFE-oil organogel, then carbonyl iron particles were dispersed in this thixotropic organogel to prepare magnetorheological fluids without any other additives. By performing a comparative investigation of MRFs' performances, enhanced magnetorheological response, suspension stability and tribological performance were obtained contrast to pure silicon oil based MRFs. The experimental results revealed a changeable viscosity of organogel, considerable increases in thixotropy also can be observed with the increase of PTFE content. Sedimentation tests demonstrated a much better suspension stability of MRFs based on organogel, suggesting that the internal network microstructures formed by hydrogen bonds between PTFE microparticles and oil molecular chains are likely to impose the gaps among magnetic particles thus hinder the particle aggregation and sedimentation. Moreover, a critical PTFE volume fraction about 4.7 vol% was recognized in this study, lower content organogels tended to display enhanced yield stresses contrast to pure silicon oil based MRFs while high content organogels showed slightly lower ones. It may suggest a compromise between nonmagnetic particle adsorption and the reinforcement effect of network microstructures. The adsorption is likely to decrease the saturation magnetization of carbonyl iron particles and to hinder the formation of field-induced chains, however, the reinforcement effect tends to strengthen these magnetic chains. Besides, the tribological tests confirmed the lubricant effects of PTFE-oil organogel by acquiring rather sharp decreases in friction coefficients of organogel based MRFs especially in the presence of magnetic field.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baohui Xu; Jiusun Zhang; Guaogeng Mao
1992-07-01
Fluoropolymers are widely used in thermal and electrical industries. Polytetrafluoroethylene (PTFE) plastic is a typical one. During its production, workers are occupationally exposed to many organic fluorides, especially tetrafluoroethylene, chlorodifluoromethane, PTFE and its thermal decomposition products. Of these compounds, it has been documented that following inhalation of combustion products of PTFE the focal hemorrhages, edema, fibrin deposition in lungs and renal infarcts were observed in rats. Odum and Green have demonstrated a marked damage to proximal tubule of kidney with no effects on the liver in rats exposed to 6000 ppm tetrafluoroethylene for 6 hr. The investigations of the hazardsmore » of these compounds to workers have been mainly focused on acute toxicity. There have been some reports that polymers and its pyrolysis caused polymer fume fever and pulmonary edema. In practice, workers engaged in PTFE manufacture are chronically exposed to the above-mentioned chemicals, but little was known about the hazards ascribed to these chemicals. To clarify the influences of the exposed chemicals on health in PTFE production we conducted a mass survey investigation in a PTFE production factory. As a result, in addition to the nephrotoxicity characterized by elevated ALP and NAG activities in urine, more interestingly, we have also found a reversible increase in cholinesterase (ChE) activity and enhanced urinary excretion of inorganic fluorides in workers engaged in PTFE production. We report here these findings and discuss their physiological significance. 18 refs., 4 tabs.« less
Fuller, Timothy J.; Jiang, Ruichun
2017-01-24
A method for forming a modified solid polymer includes a step of contacting a solid fluorinated polymer with a sodium sodium-naphthalenide solution to form a treated fluorinated solid polymer. The treated fluorinated solid polymer is contacted with carbon dioxide, sulfur dioxide, or sulfur trioxide to form a solid grafted fluorinated polymer. Characteristically, the grafted fluorinated polymer includes appended CO.sub.2H or SO.sub.2H or SO.sub.3H groups. The solid grafted fluorinated polymer is advantageously incorporated into a fuel cell as part of the ion-conducting membrane or a water transport membrane in a humidifier.
Rim, Yonghoon; Laing, Susan T.; McPherson, David D.; Kim, Hyunggun
2013-01-01
Mitral valve repair using expanded polytetrafluoroethylene (ePTFE) sutures is an established and preferred interventional method to resolve the complex pathophysiologic problems associated with chordal rupture. We developed a novel computational evaluation protocol to determine the effect of the artificial sutures on restoring mitral valve function following valve repair. A virtual mitral valve was created using three-dimensional echocardiographic data in a patient with ruptured mitral chordae tendineae. Virtual repairs were designed by adding artificial sutures between the papillary muscles and the posterior leaflet where the native chordae were ruptured. Dynamic finite element simulations were performed to evaluate pre- and post-repair mitral valve function. Abnormal posterior leaflet prolapse and mitral regurgitation was clearly demonstrated in the mitral valve with ruptured chordae. Following virtual repair to reconstruct ruptured chordae, the severity of the posterior leaflet prolapse decreased and stress concentration was markedly reduced both in the leaflet tissue and the intact native chordae. Complete leaflet coaptation was restored when four or six sutures were utilized. Computational simulations provided quantitative information of functional improvement following mitral valve repair. This novel simulation strategy may provide a powerful tool for evaluation and prediction of interventional treatment for ruptured mitral chordae tendineae. PMID:24072489
The atomic nature of polymer-metal interactions in adhesion, friction and wear
NASA Technical Reports Server (NTRS)
Buckley, D. H.; Brainard, W. A.
1973-01-01
Adhesion experiments with polytetra-fluoroethylene (PTFE) and polyimide contacting tungsten indicate that the polymers bond chemically to the clean metal surface. Polymer chain fragments which transfer to the surface of tungsten in field ion microscopy adhesion studies are highly oriented. Auger emission spectroscopy of PTFE transfer films to various metal surfaces indicates that the PTFE is bonded to the metal surface via the carbon atom. With PTFE in sliding contact with different orientations of aluminum, metal orientation is found to influence surfaces in sliding. The lowest friction and least amount of surface damage is detected on the highest atomic density (111) plane. The friction process itself can initiate polymer film formation from simple organic molecules.
Li, Yan; Jiang, Chunlan; Wang, Zaicheng; Luo, Puguang
2016-01-01
Metal/fluoropolymer composites represent a new category of energetic structural materials that release energy through exothermic chemical reactions initiated under shock loading conditions. This paper describes an experiment designed to study the reaction characteristics of energetic materials with low porosity under explosive loading. Three PTFE (polytetrafluoroethylene)/Ti/W mixtures with different W contents are processed through pressing and sintering. An inert PTFE/W mixture without reactive Ti particles is also prepared to serve as a reference. Shock-induced chemical reactions are recorded by high-speed video through a narrow observation window. Related shock parameters are calculated based on experimental data, and differences in energy release are discussed. The results show that the reaction propagation of PTFE/Ti/W energetic materials with low porosity under explosive loading is not self-sustained. As propagation distance increases, the energy release gradually decreases. In addition, reaction failure distance in PTFE/Ti/W composites is inversely proportional to the W content. Porosity increased the failure distance due to higher shock temperature. PMID:28774056
Phase dependent fracture and damage evolution of polytetrafluoroethylene (PTFE)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brown, E. N.; Rae, P.; Orler, E. B.
2004-01-01
Compared with other polymers, polytetrafluoroethylene (PTFE) presents several advantages for load-bearing structural components including higher strength at elevated temperatures and higher toughness at lowered temperatures. Failure sensitive applications of PTFE include surgical implants, aerospace components, and chemical barriers. Polytetrafluoroethylene is semicrystalline in nature with their linear chains forming complicated phases near room temperature and ambient pressure. The presence of three unique phases near room temperature implies that failure during standard operating conditions may be strongly dependent on the phase. This paper presents a comprehensive and systematic study of fracture and damage evolution in PTFE to elicit the effects of temperature-inducedmore » phase on fracture mechanisms. The fracture behavior of PTFE is observed to undergo transitions from brittle-fracture below 19 C to ductile-fracture with crazing and some stable crack growth to plastic flow aver 30 C. The bulk failure properties are correlated to failure mechanisms through fractography and analysis of the crystalline structure.« less
Effect of gamma radiation on dielectric and mechanical properties of modified fluoroplastic PTFE
NASA Astrophysics Data System (ADS)
Romanov, Boris; Kostromin, Valeriy; Bedenko, Sergey; Knyshev, Vladimir; Mukhnurov, Ilya; Matias, Rodrigo Roman
2018-03-01
The influence of gamma radiation on dielectric and mechanical characteristics of modified fluoroplast PTFE-4 MBK is considered in this paper. The material was exposed to Gamma-ray source GU-200 (Joint-stock company «Research Institute of Instruments», Lytkarino, Russia). The results of the research have shown that the relative permittivity and the tangent of the dielectric loss angle of PTFE-4 MBK samples at doses 4.105-1.106 Gy monotonically increase by 2.9 and 9.4%, respectively, compared to un-exposed material. The research of the mechanical properties of PTFE-4 MBK showed a maximum stress of up to 13.8 MPa and a maximum strain of 252% at doses of 8.104 Gy. It has been demonstrated that modified PTFE-4 MBK has good dielectric characteristics and withstanding high mechanical stress. We propose to use the results of the research for choosing cables and wiring location used in nuclear and space industry.
Spray-coating process in preparing PTFE-PPS composite super-hydrophobic coating
NASA Astrophysics Data System (ADS)
Weng, Rui; Zhang, Haifeng; Liu, Xiaowei
2014-03-01
In order to improve the performance of a liquid-floated rotor micro-gyroscope, the resistance of the moving interface between the rotor and the floating liquid must be reduced. Hydrophobic treatment can reduce the frictional resistance between such interfaces, therefore we proposed a method to prepare a poly-tetrafluoroethylene (PTFE)-poly-phenylene sulphide (PPS) composite super-hydrophobic coating, based on a spraying process. This method can quickly prepare a continuous, uniform PTFE-PPS composite super-hydrophobic surface on a 2J85 material. This method can be divided into three steps, namely: pre-treatment; chemical etching; and spraying. The total time for this is around three hours. When the PTFE concentration is 4%, the average contact angle of the hydrophobic coating surface is 158°. If silicon dioxide nanoparticles are added, this can further improve the adhesion and mechanical strength of the super-hydrophobic composite coating. The maximum average contact angle can reach as high as 164° when the mass fraction of PTFE, PPS and silicon dioxide is 1:1:1.
NASA Astrophysics Data System (ADS)
Jebran Khan, Mohammad; Wani, M. F.; Gupta, Rajat
2018-05-01
The present study aims at investigating the tribological behavior of glass fiber filled PTFE on sliding against AISI 420 stainless steel in ambient air, distilled water and natural sea water. The friction and wear tests were carried out using a pin-on-disc configuration at room temperature on 25 wt% glass fiber filled PTFE at a normal load of 10 N. The glass fiber filled PTFE showed superior tribological performance in sea water compared to dry sliding and distilled water environment conditions. The lowest average coefficient of friction of 0.028 and lowest specific wear rate of 5.85 × 10‑6 mm3 Nm‑1 was observed under sea water environment. The worn surfaces were examined using Optical microscopy, SEM, EDS and Raman spectroscopy to reveal the wear mechanisms. It was revealed that the superior tribological performance of glass fiber filled PTFE in sea water is due to the formation of a lubricating film on the surface of glass fiber filled PTFE in sea water. The profilometric traces of the counterface after tribological tests were taken using an optical 3D surface profilometer to investigate the effect of indirect corrosive wear on the friction and wear of glass fiber filled PTFE under sea water environment.
NASA Astrophysics Data System (ADS)
Koshcheev, A. P.; Perov, A. A.; Gorokhov, P. V.; Zaripov, N. V.; Tereshenkov, A. V.; Khatipov, S. A.
2018-06-01
Specific properties of PTFE composites filled with ultradisperse detonation diamonds (UDDs) with different surface chemistries are studied. It is found for the first time that filler in the form of UDDs affects not only the rate of PTFE thermal decomposition in vacuum pyrolysis, but also the chemical composition of the products of degradation. The wear resistance of UDD/PTFE composites is shown to depend strongly on the UDD surface chemistry. The presence of UDDs in a PTFE composite is found to result in perfluorocarbon telomeres, released as a readily condensable fraction upon composite pyrolysis. The chemical interaction between PTFE and UDDs, characterized by an increase in the rate of gas evolution and a change in the desorbed gas's composition, is found to occur at temperature as low as 380°C. It is shown that the intensity of this interaction depends on the concentration of oxygen-containing surface groups, the efficiency of UDDs in terms of the composite's wear resistance being reduced due to the presence of these groups. Based on the experimental data, a conclusion is reached about the chemical interaction between UDDs and a PTFE matrix, its dependence on the nanodiamond surface chemistry, and its effect on a composite's tribology.
NASA Astrophysics Data System (ADS)
Park, Byeong-Hee; Sohn, Joon-Yong; Shin, Junhwa
2016-01-01
In this study, a hydrophilic copolymer of acrylonitrile (AN) and sodium vinylsulfonate (SVS) was grafted into a highly hydrophobic porous poly(tetrafluoroethylene) (PTFE) substrate using a gamma-ray irradiation method and the grafted substrate was used as a substrate for impregnating a hydrophilic ionomer, Nafion. The results of FT-IR and TGA analysis of the prepared substrate showed that the SVS/AN monomers were successfully grafted into the porous PTFE film. The results of degree of grafting, elemental analyzer, and contact angle analysis showed that the hydrophilicity of the prepared PTFE-g-P(AN-co-VS) substrate was increased with an increase in the amount of SVS/AN graft copolymers. Also, the results of FE-SEM and Gurley number measurement showed that the pores in the substrate were reduced as the amount of SVS/AN copolymers grafted into the substrate increased. The prepared porous PTFE-g-P(AN-co-VS) substrate at an irradiation dose of 70 kGy was found to impregnate Nafion ionomer effectively compared to the original porous PTFE substrate. These results suggest that the prepared PTFE-g-P(AN-co-VS) substrate can be effectively used for the impregnation of polymer electrolyte (Nafion) to prepare a reinforced composite membrane.
NASA Astrophysics Data System (ADS)
Cho, Yong Ki; Park, Daewon; Kim, Hoonbae; Lee, Hyerim; Park, Heonyong; Kim, Hong Ja; Jung, Donggeun
2014-03-01
Bioactive surface modification can be used in a variety of medical polymeric materials in the fields of biochips and biosensors, artificial membranes, and vascular grafts. In this study, the surface modification of the inner walls of poly-tetra-fluoro-ethylene (PTFE) tubing was carried out to improve vascular grafts, which are made of biocompatible material for the human body in the medical field. Focus was centered on the cell attachment of the inner wall of the PTFE by sequential processes of hydrogen plasma treatment, hydrocarbon deposition, and reactive plasma treatment on the PFTE surface using micro plasma discharge. Micro plasma was generated by a medium-frequency alternating current high-voltage generator. The preliminary modification of PTFE was conducted by a plasma of hydrogen and argon gases. The hydrocarbon thin film was deposited on modified PTFE with a mixture of acetylene and argon gases. The reactive plasma treatment using oxygen plasma was done to give biocompatible functionality to the inner wall surface. The hydrophobic surface of bare PTFE is made hydrophilic by the reactive plasma treatment due to the formation of carbonyl groups on the surface. The reactive treatment could lead to improved attachment of smooth muscle cells (SMCs) on the modified PTFE tubing. Fourier transform infrared absorption spectroscopy, X-ray photoelectron spectroscopy, scanning electron microscopy, and water contact angle measurement were used for the analysis of the surface modification. The SMC-attached PTFE tube developed will be applicable to in vitro human vasculature-mimetic model systems, and to medical vascular grafts.
AbuRahma, Ali F.; Hopkins, Eric S.; Robinson, Patrick A.; Deel, John T.; Agarwal, Samir
2003-01-01
Objective To compare the late clinical outcome and incidence of recurrent stenosis after carotid endarterectomy (CEA) with polytetrafluoroethylene (PTFE) versus Hemashield patching. Summary Background Data Several randomized trials have confirmed the advantages of patching over primary closure when performing CEA. Methods Two hundred CEAs (180 patients) were randomized into 100 with PTFE patching and 100 with Hemashield. All patients underwent postoperative color duplex ultrasounds at 1, 6, and 12 months, and every year thereafter. The mean follow-up was 26 months. Kaplan-Meier analysis was used to estimate the risk of re-stenosis, stroke, and stroke-free survival. A multivariate analysis of various risk factors was also done. Results Demographic and clinical characteristics were similar in both groups. The incidence of all ipsilateral strokes (early and late) was 8% (7% perioperative) for Hemashield versus 0% for PTFE patching. Both groups had similar mortality rates. The cumulative stroke-free rates at 6, 12, 24, and 36 months were 93%, 93%, 93%, and 89% for Hemashield versus 100%, 100%, 100%, and 100% for PTFE patching. The cumulative stroke-free survival rates at 6, 12, 24, and 36 months were 90%, 89%, 87%, and 79% for Hemashield versus 98%, 98%, 92%, and 92% for PTFE patching. Kaplan-Meier analysis also showed that freedom from 50% or greater re-stenosis at 6, 12, 24, and 36 months was 89%, 81%, 73%, and 66% for Hemashield versus 100%, 100%, 100%, and 92% for PTFE. Similarly, the freedom from 70% or greater re-stenosis at 6, 12, 24, and 36 months was 93%, 91%, 86%, and 78% for Hemashield versus 100%, 100%, 100%, and 100% for PTFE. Univariate and multivariate analyses of demographic and preoperative risk factors showed that only Hemashield was significantly associated with a higher incidence of 70% or greater recurrent stenosis. Conclusions PTFE patching was superior to Hemashield in lowering the incidence of postoperative ipsilateral strokes and late recurrent stenosis. PMID:12796586
Pulmonary effects induced by ultrafine PTFE particles.
Johnston, C J; Finkelstein, J N; Mercer, P; Corson, N; Gelein, R; Oberdörster, G
2000-11-01
PTFE (polytetrafluoroethylene) fumes consisting of large numbers of ultrafine (uf) particles and low concentrations of gas-phase compounds can cause severe acute lung injury. Our studies were designed to test three hypotheses: (i) uf PTFE fume particles are causally involved in the induction of acute lung injury, (ii) uf PTFE elicit greater pulmonary effects than larger sized PTFE accumulation mode particles, and (iii) preexposure to the uf PTFE fume particles will induce tolerance. We used uf Teflon (PTFE) fumes (count median particle size approximately 16 nm) generated by heating PTFE in a tube furnace to 486 degrees C to evaluate principles of ultrafine particle toxicity. Teflon fumes at ultrafine particle concentrations of 50 microg/m(3) were extremely toxic to rats when inhaled for only 15 min. We found that when generated in argon, the ultrafine Teflon particles alone are not toxic at these exposure conditions; neither were Teflon fume gas-phase constituents when generated in air. Only the combination of both phases when generated in air caused high toxicity, suggesting either the existence of radicals on the surface or a carrier mechanism of the ultrafine particles for adsorbed gas compounds. Aging of the fresh Teflon fumes for 3.5 min led to a predicted coagulation to >100 nm particles which no longer caused toxicity in exposed animals. This result is consistent with a greater toxicity of ultrafine particles compared to accumulation mode particles, although changes in particle surface chemistry during the aging process may have contributed to the diminished toxicity. Furthermore, the pulmonary toxicity of the ultrafine Teflon fumes could be prevented by adapting the animals with short 5-min exposures on 3 days prior to a 15-min exposure. Messages encoding antioxidants and chemokines were increased substantially in nonadapted animals, yet were unaltered in adapted animals. This study shows the importance of preexposure history for the susceptibility to acute ultrafine particle effects. Copyright 2000 Academic Press.
Deasy, William; Shepherd, Tom; Alexander, Colin J; Birch, A Nicholas E; Evans, K Andrew
2016-11-01
Research on plant root chemical ecology has benefited greatly from recent developments in analytical chemistry. Numerous reports document techniques for sampling root volatiles, although only a limited number describe in situ collection. To demonstrate a new method for non-invasive in situ passive sampling using solid phase micro extraction (SPME), from the immediate vicinity of growing roots. SPME fibres inserted into polyfluorotetrafluoroethylene (PTFE) sampling tubes located in situ which were either perforated, covered with stainless steel mesh or with microporous PTFE tubing, were used for non-invasive sub-surface sampling of root volatiles from glasshouse-grown broccoli. Sampling methods were compared with above surface headspace collection using Tenax TA. The roots were either mechanically damaged or infested with Delia radicum larvae. Principal component analysis (PCA) was used to investigate the effect of damage on the composition of volatiles released by broccoli roots. Analyses by gas chromatography-mass spectrometry (GC-MS) with SPME and automated thermal desorption (ATD) confirmed that sulphur compounds, showing characteristic temporal emission patterns, were the principal volatiles released by roots following insect larval damage. Use of SPME with in situ perforated PTFE sampling tubes was the most robust method for out-of-lab sampling. This study describes a new method for non-invasive passive sampling of volatiles in situ from intact and insect damaged roots using SPME. The method is highly suitable for remote sampling and has potential for wide application in chemical ecology/root/soil research. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Active screen cage pulsed dc discharge for implanting copper in polytetrafluoroethylene (PTFE)
NASA Astrophysics Data System (ADS)
Zaka-ul-Islam, Mujahid; Naeem, Muhammad; Shafiq, Muhammad; Sitara; Jabbar Al-Rajab, Abdul; Zakaullah, Muhammad
2017-07-01
Polymers such as polytetrafluoroethylene (PTFE) are widely used in artificial organs where long-term anti-bacterial properties are required to avoid bacterial proliferation. Copper or silver ion implantation on the polymer surface is known as a viable method to generate long-term anti-bacterial properties. Here, we have tested pulsed DC plasma with copper cathodic cage for the PTFE surface treatment. The surface analysis of the treated specimens suggests that the surface, structural properties, crystallinity and chemical structure of the PTFE have been changed, after the plasma treatment. The copper release tests show that copper ions are released from the polymer at a slow rate and quantity of the released copper increases with the plasma treatment time.
Friction coefficient dependence on electrostatic tribocharging
Burgo, Thiago A. L.; Silva, Cristiane A.; Balestrin, Lia B. S.; Galembeck, Fernando
2013-01-01
Friction between dielectric surfaces produces patterns of fixed, stable electric charges that in turn contribute electrostatic components to surface interactions between the contacting solids. The literature presents a wealth of information on the electronic contributions to friction in metals and semiconductors but the effect of triboelectricity on friction coefficients of dielectrics is as yet poorly defined and understood. In this work, friction coefficients were measured on tribocharged polytetrafluoroethylene (PTFE), using three different techniques. As a result, friction coefficients at the macro- and nanoscales increase many-fold when PTFE surfaces are tribocharged, but this effect is eliminated by silanization of glass spheres rolling on PTFE. In conclusion, tribocharging may supersede all other contributions to macro- and nanoscale friction coefficients in PTFE and probably in other insulating polymers. PMID:23934227
Polytetrafluoroetylene tape as temporary restorative material: a fluid filtration study.
Olcay, Keziban; Steier, Liviu; Erdogan, Hilal
2015-01-01
The purpose of this study was to compare the sealing ability of temporary restorative materials at 24 hrs and 1 week. Endodontic access cavities were prepared in 56 extracted lower incisor-teeth and divided into 5 groups (n=10). Standard 5 mm deep access preparations were completed and root canals were prepared to size ISO #30 file. The access cavities were restored as follows: Group 1: temporary restorative material (Ceivitron); Group 2: glass ionomer cement (Fuji II); Group 3: zinc oxide-eugenol cement (IRM); Group 4: zinc phosphate cement (Adhesor); Group 5: polytetrafluoroetylene tape (PTFE). The quality of the coronal sealing of each specimen was measured (24 hrs and 1 week) using fluid transport model. The data was analyzed with repeated measurements ANOVA, Tukey' HSD and Paired samples T-Tests. A significant difference was found among the groups at all time-periods (p<0.05). At 24 hrs, PTFE showed similar leakage with Ceivitron, IRM, and Fuji II but it showed higher leakage than Adhesor. At 1 week, Ceivitron showed higher leakage than PTFE, meanwhile PTFE showed similar leakage with IRM, Fuji II, and Adhesor (p>0.05). Sealing ability of IRM and PTFE groups significantly increased by time (p<0.05 and p<0.001 respectively). Within the limitations of this study, PTFE showed an acceptable short-term sealing capability when compared to the other commonly used temporary restorative materials at 1 week measurements.
NASA Astrophysics Data System (ADS)
Kim, Hyonchol; Ishibashi, Kenta; Matsuo, Kosuke; Kira, Atsushi; Onomura, Yui; Okada, Tomoko; Nakamura, Chikashi
2018-03-01
Cell adhesion strengths to various substrates were quantitatively measured using atomic force microscopy (AFM). A cup-shaped metal hemisphere was attached to the apex of the AFM cantilever, the “cup-chip” approached a cell (FP10SC2) to pick it up, the captured cell approached any one of six different substrates [gold (Au), nickel (Ni), bovine serum albumin (BSA), an amino group (NH2), poly(tetrafluoroethylene) (PTFE), and structured PTFE (sPTFE)], and the cell adhesion strength at the initial contact period was evaluated by detaching the cell from the substrate. The results obtained showed that the force needed to detach the cell from the NH2 substrate was more than 3-fold larger than that of metal substrates (Au and Ni), more than 15-fold larger than that of biochemically treated substrates (BSA), and more than 20-fold larger than that of hydrophobic substrates (PTFE and sPTFE). Using differences in adhesion strengths, a cell on a sPTFE substrate was picked up using a BSA-coated cup-chip, placed on a NH2 substrate, repeating this cell manipulation five times, and line patterning of cells was achieved. These results indicate that measurements of cell adhesion strength are fundamental to fabricate desired cell networks and the cup-chip is a useful tool for achieving easy cell manipulation.
VUV light reflectivity measurements from PTFE in Liquid Xenon for the LZ Dark Matter experiment
NASA Astrophysics Data System (ADS)
Pushkin, Kirill; LZ Collaboration
2016-03-01
The LUX-Zeplin (LZ) collaboration is the next generation of the experiment to search for Dark Matter in the Universe with a dual-phase detector based on liquid xenon (LXe) with a target mass of 7 ton. LXe dual phase detectors are very sensitive probes to search for WIMP dark matter interactions. The LZ collaboration is conducting R&D to study VUV light reflectivity from PTFE (Teflon) in LXe. Teflon is used in dual phase detectors both as an electrical insulator and as reflector of VUV scintillation light (~175 nm) to improve photon detection with photomultiplier tubes (PMTs). However, experimental data for the reflectance of VUV light from PTFE in LXe is not sufficiently conclusive. We present a new technique of measuring the light reflectivity from PTFE by varying the fractional area of the PMT in the detector. PTFE reflectivity measurements were performed as a function of Teflon wall thickness in the range of 2 mm to 9.5 mm. The method, apparatus and experimental results will be presented.
NASA Astrophysics Data System (ADS)
Park, Byung Hyun; Lee, Myong-Hwa; Kim, Sang Bum; Jo, Young Min
2011-02-01
A newly developed PTFE foam coating filter was developed which can be used for hot gas cleaning at temperatures up to 250 °C. The emulsion-type PTFE was coated onto a woven glass fiber using a foam coating method. The filter surface was closely examined using X-ray photoelectron spectroscopy (XPS) and contact angle measurements. The XPS results were used to determine the binding force between the carbon and fluorine of PTFE, which imparts coating stability to the filter medium. More than 95% of the bonds of the PTFE foam coating filter were between carbon and fluorine, and this filter demonstrated excellent hydrophobic and good oleophobic properties at the same time. The contact angles of liquid droplets on the filter surface were used to predict the potential wetability of the filter against water or oil. In addition, the very low surface free energy of the filter medium, which was evaluated using the Owens-Wendt method, demonstrates a very stable surface and a high de-dusting quality.
Guerrini, Edoardo; Grattieri, Matteo; Faggianelli, Alessio; Cristiani, Pierangela; Trasatti, Stefano
2015-12-01
Influence of PTFE in the external Gas Diffusion Layer (GDL) of open-air cathodes applied to membraneless microbial fuel cells (MFCs) is investigated in this work. Electrochemical measurements on cathodes with different PTFE contents (200%, 100%, 80% and 60%) were carried out to characterize cathodic oxygen reduction reaction, to study the reaction kinetics. It is demonstrated that ORR is not under diffusion-limiting conditions in the tested systems. Based on cyclic voltammetry, an increase of the cathodic electrochemical active area took place with the decrease of PTFE content. This was not directly related to MFC productivity, but to the cathode wettability and the biocathode development. Low electrodic interface resistances (from 1 to 1.5 Ω at the start, to near 0.1 Ω at day 61) indicated a negligible ohmic drop. A decrease of the Tafel slopes from 120 to 80 mV during productive periods of MFCs followed the biological activity in the whole MFC system. A high PTFE content in the cathode showed a detrimental effect on the MFC productivity, acting as an inhibitor of ORR electrocatalysis in the triple contact zone.
Brown, G L; Richardson, J D; Malangoni, M A; Tobin, G R; Ackerman, D; Polk, H C
1985-01-01
Abdominal wall defects resulting from trauma, invasive infection, or hernia present a difficult problem for the surgeon. In order to study the problems associated with the prosthetic materials used for abdominal wall reconstruction, an animal model was used to simulate abdominal wall defects in the presence of peritonitis and invasive infection. One hundred guinea pigs were repaired with either polytetrafluorethylene (PTFE) or polypropylene mesh (PPM). Our experiments included intra-operative contamination with Staphylococcus aureus. We found significantly fewer organisms (p less than 0.05) adherent to the PTFE than to the PPM when antibiotics were administered after surgery, as well as when no antibiotics were given. In the presence of peritonitis, we found no real difference in numbers of intraperitoneal bacteria present whether PTFE or PPM was used. In all instances, the PTFE patches produced fewer adhesions and were more easily removed. From these experiments, it appears that PTFE may be associated with fewer problems than PPM in the presence of contamination and infection. Images FIG. 1. PMID:3159353
Creation and Validation of Sintered PTFE BRDF Targets & Standards.
Durell, Christopher; Scharpf, Dan; McKee, Greg; L'Heureux, Michelle; Georgiev, Georgi; Obein, Gael; Cooksey, Catherine
2015-09-21
Sintered polytetrafluoroethylene (PTFE) is an extremely stable, near-perfect Lambertian reflecting diffuser and calibration standard material that has been used by national labs, space, aerospace and commercial sectors for over two decades. New uncertainty targets of 2 % on-orbit absolute validation in the Earth Observing Systems community have challenged the industry to improve is characterization and knowledge of almost every aspect of radiometric performance (space and ground). Assuming "near perfect" reflectance for angular dependent measurements is no longer going to suffice for many program needs. The total hemispherical spectral reflectance provides a good mark of general performance; but, without the angular characterization of bidirectional reflectance distribution function (BRDF) measurements, critical data is missing from many applications and uncertainty budgets. Therefore, traceable BRDF measurement capability is needed to characterize sintered PTFE's angular response and provide a full uncertainty profile to users. This paper presents preliminary comparison measurements of the BRDF of sintered PTFE from several laboratories to better quantify the BRDF of sintered PTFE, assess the BRDF measurement comparability between laboratories, and improve estimates of measurement uncertainties under laboratory conditions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yamaguchi, Akinobu, E-mail: yamaguti@lasti.u-hyogo.ac.jp, E-mail: utsumi@lasti.u-hyogo.ac.jp; Kido, Hideki; Utsumi, Yuichi, E-mail: yamaguti@lasti.u-hyogo.ac.jp, E-mail: utsumi@lasti.u-hyogo.ac.jp
2016-02-01
We developed a process for micromachining polytetrafluoroethylene (PTFE): anisotropic pyrochemical microetching induced by synchrotron X-ray irradiation. X-ray irradiation was performed at room temperature. Upon heating, the irradiated PTFE substrates exhibited high-precision features. Both the X-ray diffraction peak and Raman signal from the irradiated areas of the substrate decreased with increasing irradiation dose. The etching mechanism is speculated as follows: X-ray irradiation caused chain scission, which decreased the number-average degree of polymerization. The melting temperature of irradiated PTFE decreased as the polymer chain length decreased, enabling the treated regions to melt at a lower temperature. The anisotropic pyrochemical etching process enabledmore » the fabrication of PTFE microstructures with higher precision than simultaneously heating and irradiating the sample.« less
ERIC Educational Resources Information Center
Mong, Michael D.; Mong, Kristi W.
2012-01-01
The present study evaluated the utility of brief experimental analysis (BEA) in predicting effective interventions for increasing the math fluency of 3 elementary students identified as having math skill deficits. Baseline data were collected followed by implementation of a BEA consisting of the following interventions: cover, copy, and compare,…
NASA Astrophysics Data System (ADS)
Barry, Peter R.
Polytetrafluoroethylene (PTFE) is a polymer that has been widely exploited commercially as a result of its low friction, 'non-stick' properties. The polymer has found usage as 'non-stick,' chemically resistant coatings for bearings, valves, rollers and pipe linings with applications in industries ranging from food and chemical processing to construction, automotive and aerospace. The major drawback of PTFE in low friction applications involves its excessive wear rate. For decades, scientists and engineers have sought to improve the polymer's wear resistance while maintaining its low sliding friction by reinforcing the polymer matrix with a host of filler materials ranging from fibril to particulate. In this study, a different approach is taken in which the atomic scale phenomena between two crystalline PTFE surfaces in sliding contact are examined. The goal is to obtain atomic-level insights into PTFE's low friction and high wear rate to aid in the designing of effective polymer based tribological composites for extreme condition applications. To accomplish this, several tribological conditions were varied. These included sliding direction of the two polymer surfaces with respect to their chain alignment, sliding velocity, degree of crystalline phase rigidity, interfacial contact pressure, sample temperature and the presence of fluorocarbon fluids between the two crystalline PTFE surfaces. From these studies, it was found that crystalline PTFE-PTFE sliding demonstrates friction anisotropy. Low friction and molecular wear was observed when sliding in the direction of the chain alignment with high friction and wear behavior dominating when sliding in a direction perpendicular to the chain alignment. For the range of cross-link density (average linear density of 6.2 to 11.1 A) and sliding rate (5 m/s to 20 m/s) explored, a significant change in friction behavior or wear mechanisms was not observed. Under conditions of increased normal load or low temperature however, the frictional force increased linearly. Additionally, the inclusion of fluorocarbon molecular fluids at the sliding interface between the two crystalline PTFE surfaces resulted in a significant decrease in both the friction and wear of the surfaces.
Panda, Anton; Dyadyura, Kostiantyn; Valíček, Jan; Harničárová, Marta; Zajac, Jozef; Modrák, Vladimír; Pandová, Iveta; Vrábel, Peter; Nováková-Marcinčínová, Ema; Pavelek, Zdeněk
2017-01-01
The results of the investigations into the technological formation of new wear-resistant polymer composites based on polytetrafluoroethylene (PTFE) filled with disperse synthetic and natural compounds are presented. The efficiency of using PTFE composites reinforced with carbon fibers depends on many factors, which influence the significant improvement of physicomechanical characteristics. The results of this research allow stating that interfacial and surface phenomena of the polymer–solid interface and composition play a decisive role in PTFE composites properties. Fillers hinder the relative movement of the PTFE molecules past one another and, in this way, reduce creep or deformation of the parts, reducing the wear rate of parts used in dynamic applications as well as the coefficient of thermal expansion. The necessary structural parameters of such polymer composites are provided by regimes of process equipment. PMID:28772733
Panda, Anton; Dyadyura, Kostiantyn; Valíček, Jan; Harničárová, Marta; Zajac, Jozef; Modrák, Vladimír; Pandová, Iveta; Vrábel, Peter; Nováková-Marcinčínová, Ema; Pavelek, Zdeněk
2017-03-31
The results of the investigations into the technological formation of new wear-resistant polymer composites based on polytetrafluoroethylene (PTFE) filled with disperse synthetic and natural compounds are presented. The efficiency of using PTFE composites reinforced with carbon fibers depends on many factors, which influence the significant improvement of physicomechanical characteristics. The results of this research allow stating that interfacial and surface phenomena of the polymer-solid interface and composition play a decisive role in PTFE composites properties. Fillers hinder the relative movement of the PTFE molecules past one another and, in this way, reduce creep or deformation of the parts, reducing the wear rate of parts used in dynamic applications as well as the coefficient of thermal expansion. The necessary structural parameters of such polymer composites are provided by regimes of process equipment.
Thermal desorption study of physical forces at the PTFE surface
NASA Technical Reports Server (NTRS)
Wheeler, D. R.; Pepper, S. V.
1987-01-01
Thermal desorption spectroscopy (TDS) of the polytetrafluoroethylene (PTFE) surface was successfully employed to study the possible role of physical forces in the enhancement of metal-PTFE adhesion by radiation. The thermal desorption spectra were analyzed without assumptions to yield the activation energy for desorption over a range of xenon coverage from less than 0.1 monolayer to more than 100 monolayers. For multilayer coverage, the desorption is zero-order with an activation energy equal to the sublimation energy of xenon. For submonolayer coverages, the order for desorption from the unirradiated PTFE surface is 0.73 and the activation energy for desorption is between 3.32 and 3.36 kcal/mol; less than the xenon sublimation energy. The effect of irradiation is to increase the activation energy for desorption to as high as 4 kcal/mol at low coverage.
Thermal desorption study of physical forces at the PTFE surface
NASA Technical Reports Server (NTRS)
Wheeler, D. R.; Pepper, S. V.
1985-01-01
Thermal desorption spectroscopy (TDS) of the polytetrafluoroethylene (PTFE) surface was successfully employed to study the possibile role of physical forces in the enhancement of metal-PTFE adhesion by radiation. The thermal desorption spectra were analyzed without assumptions to yield the activation energy for desorption over a range of xenon coverage from less than 0.1 monolayer to more than 100 monolayers. For multilayer coverage, the desorption is zero-order with an activation energy equal to the sublimation energy of xenon. For submonolayer coverages, the order for desorption from the unirradiated PTFE surface is 0.73 and the activation energy for desorption is between 3.32 and 3.36 kcal/mol; less than the xenon sublimation energy. The effect of irradiation is to increase the activation energy for desorption to as high as 4 kcal/mol at low coverage.
Simulation of Particle Size Effect on Dynamic Properties and Fracture of PTFE-W-Al Composites
NASA Astrophysics Data System (ADS)
Herbold, E. B.; Cai, J.; Benson, D. J.; Nesterenko, V. F.
2007-12-01
Recent investigations of the dynamic compressive strength of cold isostatically pressed composites of polytetrafluoroethylene (PTFE), tungsten (W) and aluminum (Al) powders show significant differences depending on the size of metallic particles. The addition of W increases the density and changes the overall strength of the sample depending on the size of W particles. To investigate relatively large deformations, multi-material Eulerian and arbitrary Lagrangian-Eulerian methods, which have the ability to efficiently handle the formation of free surfaces, were used. The calculations indicate that the increased sample strength with fine metallic particles is due to the dynamic formation of force chains. This phenomenon occurs for samples with a higher porosity of the PTFE matrix compared to samples with larger particle size of W and a higher density PTFE matrix.
Liu, Cong; Li, Yanqing; Liao, Ruijin; Liao, Qiang; Tang, Chao
2018-01-01
Cellulose insulation polymer is an important component of oil-paper insulation, which is widely used in power transformer. The weight of the cellulose insulation polymer materials is as high as tens of tons in the larger converter transformer. Excellent performance of oil-paper insulation is very important for ensuring the safe operation of larger converter transformer. An effective way to improve the insulation and the physicochemical property of the oil impregnated insulation pressboard/paper is currently a popular research topic. In this paper, the polytetrafluoroethylene (PTFE) functional film was coated on the cellulose insulation pressboard by radio frequency (RF) magnetron sputtering to improve its breakdown voltage and the hydrophobicity properties. X-ray photoelectron spectroscopy (XPS) results show that the nano-structure PTFE functional film was successfully fabricated on the cellulose insulation pressboard surface. The scanning electron microscopy (SEM) and X-ray diffraction (XRD) present that the nanoscale size PTFE particles were attached to the pressboard surface and it exists in the amorphous form. Atomic force microscopy (AFM) shows that the sputtered pressboard surface is still rough. The rough PTFE functional film and the reduction of the hydrophilic hydroxyl of the surface due to the shielding effect of PTFE improve the breakdown and the hydrophobicity properties of the cellulose insulation pressboard obviously. This paper provides an innovative way to improve the performance of the cellulose insulation polymer. PMID:29883376
Hao, Jian; Liu, Cong; Li, Yanqing; Liao, Ruijin; Liao, Qiang; Tang, Chao
2018-05-21
Cellulose insulation polymer is an important component of oil-paper insulation, which is widely used in power transformer. The weight of the cellulose insulation polymer materials is as high as tens of tons in the larger converter transformer. Excellent performance of oil-paper insulation is very important for ensuring the safe operation of larger converter transformer. An effective way to improve the insulation and the physicochemical property of the oil impregnated insulation pressboard/paper is currently a popular research topic. In this paper, the polytetrafluoroethylene (PTFE) functional film was coated on the cellulose insulation pressboard by radio frequency (RF) magnetron sputtering to improve its breakdown voltage and the hydrophobicity properties. X-ray photoelectron spectroscopy (XPS) results show that the nano-structure PTFE functional film was successfully fabricated on the cellulose insulation pressboard surface. The scanning electron microscopy (SEM) and X-ray diffraction (XRD) present that the nanoscale size PTFE particles were attached to the pressboard surface and it exists in the amorphous form. Atomic force microscopy (AFM) shows that the sputtered pressboard surface is still rough. The rough PTFE functional film and the reduction of the hydrophilic hydroxyl of the surface due to the shielding effect of PTFE improve the breakdown and the hydrophobicity properties of the cellulose insulation pressboard obviously. This paper provides an innovative way to improve the performance of the cellulose insulation polymer.
Introduction of oxygen vacancies and fluorine into TiO{sub 2} nanoparticles by co-milling with PTFE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Senna, Mamoru, E-mail: senna@applc.keio.ac.jp; Sepelak, Vladimir; Shi, Jianmin
2012-03-15
Solid-state processes of introducing oxygen vacancies and transference of fluorine to n-TiO{sub 2} nanoparticles by co-milling with poly(tetrafluoroethylene) (PTFE) powder were examined by diffuse reflectance spectroscopy (DRS) of UV, visual, near- and mid-IR regions, thermal analyses (TG-DTA), energy-dispersive X-ray spectroscopy (EDXS), X-ray photoelectron spectroscopy (XPS), high-resolution transmission electron microscopy (HRTEM) and X-ray diffraction (XRD). The broad absorption peak at around 8800 cm{sup -1} (1140 nm) was attributed to the change in the electronic states, viz. electrons trapped at the oxygen vacancies (Vo) and d-d transitions of titanium ions. Incorporation of fluorine into n-TiO{sub 2} was concentrated at the near surfacemore » region and amounted to ca. 40 at% of the total fluorine in PTFE, after co-milling for 3 h, as confirmed by the F1s XPS spectrum. The overall atomic ratio, F/Ti, determined by EDXS was 0.294. By combining these analytical results, a mechanism of the present solid state processes at the boundary between PTFE and n-TiO{sub 2} was proposed. The entire process is triggered by the partial oxidative decomposition of PTFE. This is accompanied by the abstraction of oxygen atoms from the n-TiO{sub 2} lattices. Loss of the oxygen atoms results in the formation of the diverse states of locally distorted coordination units of titania, i.e. TiO{sub 6-n}Vo{sub n}, located at the near surface region. This leads subsequent partial ligand exchange between F and O, to incorporate fluorine preferentially to the near surface region of n-TiO{sub 2} particles, where local non-crystalline states predominate. - Graphical abstract: Scheme of the reaction processes: (a) pristine mixture, (b) oxygen abstraction from TiO{sub 2} and (c) fluorine migration from PTFE to TiO{sub 2}. Highlights: Transfer of fluorine from PTFE to n-TiO{sub 2} in a dry solid state process was confirmed. Black-Right-Pointing-Pointer 40% of F in PTFE was incorporated to the near surface region of n-TiO{sub 2} nanoparticles. Black-Right-Pointing-Pointer The transfer process is triggered by the oxidative decomposition of PTFE. Black-Right-Pointing-Pointer Fluorine incorporation is mediated by the formation of oxygen vacancies. Black-Right-Pointing-Pointer The sequential mechanisms are verified by XPS, EDXS, HRTEM, TG and DRS.« less
Evaluation of transfer films of Salox M on 440C for HPOTP bearing cage applications, task 119
NASA Technical Reports Server (NTRS)
Barber, S. A.; Kannel, J. W.; Dufrane, K. F.
1986-01-01
The objective of the task was to evaluate the suitability of a bronze-filled polytetra fluoroethylene (Salox M) as the cage material in Space Shuttle Main Engine (SSME) high pressure oxygen turbo pump (HPOTP) bearings. The role of the cage pocket material will be to provide a transferred lubricating interface at the ball-race contact region. A series of experiments was conducted which involved block-on-ring tests (the block was the polytetrafluoroethylene (PTFE) -filled material and the ring was through-hardened 440C steel) and high speed traction tests of two 440C disks with one disk rubbed with a PTFE block to generate a transfer film. Measurements included post test visual observations of the condition of the 440C, wear rate measurements of the blocks, and traction measurements between the disks. It was observed that both Salox M and glass-filled PTFE (Armalon) transferred PTFE to 440C at cryogenic temperatures. Bronze is also transferred to uncoated 440C from the Salox M. At room temperature no PTFE transfer was observed in the high speed disk tests due to severe frictional heating, although bronze transfer still occurred with the bronze-PTFE Salox M material. Since the bearing will operate at cryogenic temperature, transfer films are very probable. Salox M wore slightly, although probably tolerably, more than glass-filled PTFE against 440C. However, Salox M is clearly less abrasive to 440C than is the glass-filled material. When the surface layer of PTFE is depleted from the glass-filled material, the glass fibers tend to seriously abrade the steel. This problem does not occur with Salox M. The surface roughness studies indicate that smooth balls are quite reasonable for transfer films. No significant difference in wear rates of the candidate cage materials was observed when the 440C surface finish was increased from 0.025 micron to 0.1 micron cla. At higher levels of roughness, the wear rate increased. Two surface coatings (MoS2 and TiN) were tested. The surface coatings tended to reduce the Salox M wear rate and reduce bronze transfer. PTFE transfer at cryogenic temperatures still occurred with the surface coatings. Two cage design concepts are presented utilizing Salox M material. One design involves a metal-reinforced Salox M cage, while the second design uses Salox M inserts in a metal structure.
Saxon, Richard R; Chervu, Arun; Jones, Paul A; Bajwa, Tanvir K; Gable, Dennis R; Soukas, Peter A; Begg, Richard J; Adams, John G; Ansel, Gary M; Schneider, Darren B; Eichler, Charles M; Rush, Michael J
2013-02-01
To evaluate the performance of a heparin-bonded, expanded polytetrafluoroethylene (ePTFE)-lined nitinol endoprosthesis in the treatment of long-segment occlusive disease of the femoropopliteal artery (FPA) and to identify factors associated with loss of patency. In a single-arm, prospective, 11-center study (VIPER [Gore Viabahn Endoprosthesis with Heparin Bioactive Surface in the Treatment of Superficial Femoral Artery Obstructive Disease] trial), 119 limbs (113 patients; 69 men; mean age, 67 y), including 88 with Rutherford category 3-5 disease and 72 with Inter-Society Consensus for the Management of Peripheral Arterial Disease (TASC II) C or D lesions of the FPA, underwent stent graft implantation. The mean lesion length was 19 cm; 56% of lesions were occlusions. Follow-up evaluations included color duplex ultrasonography in all patients, with patency defined as a peak systolic velocity ratio< 2.5. At 12 months, Rutherford category and ankle-brachial index (ABI) were significantly improved (mean category improvement, 2.4; ABI increased from 0.6±0.2 to 0.9±0.19; P<.0001). Primary and secondary patency rates were 73% and 92%. The primary patency for devices oversized<20% at the proximal landing zone was 88%, whereas the primary patency for devices oversized by>20% was 70% (P = .047). Primary patency was not significantly affected by device diameter (5 vs 6 vs 7 mm) or lesion length (≤20 cm vs>20 cm). The 30-day major adverse event rate was 0.8%. The heparin-bonded, ePTFE/nitinol stent graft provided clinical improvement and a primary patency rate of 73% at 1 year in the treatment of long-segment FPA disease. Careful sizing of the device relative to vessel landing zones is essential for achieving optimal outcomes. Copyright © 2013 SIR. Published by Elsevier Inc. All rights reserved.
Xu, Tong-yi; Zhang, Zhi-gang; Li, Xin; Han, Lin; Xu, Zhi-yun
2014-01-01
Background Since 2000, transcatheter pulmonary valve replacement has steadily advanced. However, the available prosthetic valves are restricted to bioprosthesis which have defects like poor durability. Polymeric heart valve is thought as a promising alternative to bioprosthesis. In this study, we introduced a novel polymeric transcatheter pulmonary valve and evaluated its feasibility and safety in sheep by a hybrid approach. Methods We designed a novel polymeric trileaflet transcatheter pulmonary valve with a balloon-expandable stent, and the valve leaflets were made of 0.1-mm expanded polytetrafluoroethylene (ePTFE) coated with phosphorylcholine. We chose glutaraldehyde-treated bovine pericardium valves as control. Pulmonary valve stents were implanted in situ by a hybrid transapical approach in 10 healthy sheep (8 for polymeric valve and 2 for bovine pericardium valve), weighing an average of 22.5±2.0 kg. Angiography and cardiac catheter examination were performed after implantation to assess immediate valvular functionality. After 4-week follow-up, angiography, echocardiography, computed tomography, and cardiac catheter examination were used to assess early valvular function. One randomly selected sheep with polymeric valve was euthanized and the explanted valved stent was analyzed macroscopically and microscopically. Findings Implantation was successful in 9 sheep. Angiography at implantation showed all 9 prosthetic valves demonstrated orthotopic position and normal functionality. All 9 sheep survived at 4-week follow-up. Four-week follow-up revealed no evidence of valve stent dislocation or deformation and normal valvular and cardiac functionality. The cardiac catheter examination showed the peak-peak transvalvular pressure gradient of the polymeric valves was 11.9±5.0 mmHg, while that of two bovine pericardium valves were 11 and 17 mmHg. Gross morphology demonstrated good opening and closure characteristics. No thrombus or calcification was seen macroscopically. Conclusions This design of the novel ePTFE transcatheter pulmonary valve is safe and effective to deploy in sheep by hybrid approach, and the early valvular functionality is good. PMID:24926892
NASA Technical Reports Server (NTRS)
Golub, Morton A.; Wydeven, Theodore; Cormia, Robert D.
1991-01-01
The presence of hydrocarbon contamination on the surface of polytetrafluoroethylene (PTFE) markedly affects the oxygen uptake, and hence the wettability, of this polymer when exposed to an oxygen plasma. As revealed by X-ray photoelectron spectroscopy (XPS) analysis, the oxygen-to-carbon ratio (O/C) for such a polymer can increase sharply, and correspondingly the fluorine-to-carbon ratio (F/C) can decrease sharply, at very short exposure times; at longer times, however, such changes in the O/C and F/C ratios reverse direction, and these ratios then assume values similar to those of the unexposed PTFE. The greater the extent of hydrocarbon contamination in the PTFE, the larger are the amplitudes of the 'spikes' in the O/C- and F/C-exposure time plots. In contrast, a pristine PTFE experiences a very small, monotonic increase of surface oxidation or O/C ratio with time of exposure to oxygen atoms, while the F/C ratio is virtually unchanged from that of the unexposed polymer (2.0). Unless the presence of adventitious hydrocarbon is taken into account, anomalous surface properties relating to polymer adhesion may be improperly ascribed to PTFE exposed to an oxygen plasma.
Effect of simulation conditions on friction in polytetrafluoroethylene (PTFE)
NASA Astrophysics Data System (ADS)
Barry, Peter R.; Jang, Inkook; Perry, Scott S.; Sawyer, W. Gregory; Sinnott, Susan B.; Phillpot, Simon R.
2007-12-01
We report the results of molecular-dynamics simulations of friction at polytetrafluoroethylene (PTFE) interfaces and show that the calculated tribological properties are robust against significant changes in the sliding speed and the morphology of the polymer.
Rapid direct micromachining of PTFE using MeV ions in an oxygen rich atmosphere
NASA Astrophysics Data System (ADS)
Grime, G. W.; Sofield, C. J.; Gomez-Morilla, I.; Gwilliam, R.; Ynsa, M. D.; Enguita, O.
2005-04-01
We have investigated the mechanism of high rate erosion which is observed when polytetrafluoroethylene (PTFE) is exposed to MeV protons in an oxygen rich atmosphere (e.g. air). Using currents of the order of nA, it is possible to create holes with depths of millimetres and diameter defined by the beam area on the surface with exposure times of minutes. This is not observed in atmospheres of nitrogen, helium or argon nor in vacuum. We propose that the erosion is a result of the formation of a stable gaseous compound following beam induced decomposition of the PTFE (possibly an acyl fluoride) which does not re-deposit in the hole. We present the results of experiments leading to this hypothesis and propose a method for fabricating three-dimensional structures in PTFE with micrometre feature size. This process is the subject of an international patent application.
Adhesion and transfer of polytetrafluoroethylene to tungsten studied by field ion microscopy
NASA Technical Reports Server (NTRS)
Brainard, W. A.; Buckley, D. H.
1972-01-01
Mechanical contacts between polytetrafluoroethylene (PTFE) and tungsten field ion tips were made in situ in the field ion microscope. Both load and force of adhesion were measured for varying contact times and for clean and contaminated tungsten tips. Strong adhesion between the PTFE and clean tungsten was observed at contact times greater than 2.5 min (forces of adhesion were greater than three times the load). For times less than 2.5 min, the force of adhesion was immeasurably small. The increase in adhesion with contact time after 2.5 min can be attributed to the increase in true contact area by creep of PTFE. No adhesion was measurable at long contact times with contaminated tungsten tips. Neon field ion micrographs taken after the contacts show many linear and branched arrays which appear to represent PTFE that remains adhered to the surface even at the high electric fields required for imaging.
Roll, Stephanie; Müller-Nordhorn, Jacqueline; Keil, Thomas; Scholz, Hans; Eidt, Daniela; Greiner, Wolfgang; Willich, Stefan N
2008-01-01
Background In peripheral vascular bypass surgery different synthetic materials are available for bypass grafting. It is unclear which of the two commonly used materials, polytetrafluoroethylene (PTFE) or polyester (Dacron®) grafts, is to be preferred. Thus, the aim of this meta-analysis and systematic review was to compare the effectiveness of these two prosthetic bypass materials (Dacron® and PTFE). Methods We performed a systematic literature search in MEDLINE, Cochrane-Library – CENTRAL, EMBASE and other databases for relevant publications in English and German published between 1999 and 2008. Only randomized controlled trials were considered for inclusion. We assessed the methodological quality by means of standardized checklists. Primary patency was used as the main endpoint. Random-effect meta-analysis as well as pooling data in life table format was performed to combine study results. Results Nine randomized controlled trials (RCT) were included. Two trials showed statistically significant differences in primary patency, one favouring Dacron® and one favouring PTFE grafts, while 7 trials did not show statistically significant differences between the two materials. Meta-analysis on the comparison of PTFE vs. Dacron® grafts yielded no differences with regard to primary patency rates (hazard ratio 1.04 (95% confidence interval [0.85;1.28]), no significant heterogeneity (p = 0.32, I2 = 14%)). Similarly, there were no significant differences with regard to secondary patency rates. Conclusion Systematic evaluation and meta-analysis of randomized controlled trials comparing Dacron® and PTFE as bypass materials for peripheral vascular surgery showed no evidence of an advantage of one synthetic material over the other. PMID:19099583
Fernández-Rivero, Marcelo Ernesto; Del Pozo, José L; Valentín, Amparo; Fornes, Victoria; Molina de Diego, Araceli; Pemán, Javier; Cantón, Emilia
Current therapeutic strategies have a limited efficacy against Candida biofilms that form on the surfaces of biomedical devices. Few studies have evaluated the activity of antifungal agents against Candida tropicalis biofilms. To evaluate the activity of amphotericin B (AMB) and anidulafungin (AND), alone and in combination, against C. tropicalis biofilms developed on polytetrafluoroethylene (teflon -PTFE) and titanium surfaces using time-kill assays. Assays were performed using the CDC Biofilm Reactor equipped with PTFE and titanium disks with C. tropicalis biofilms after 24h of maturation. The concentrations assayed were 40mg/l for AMB and 8mg/l for AND, both alone and combined. After 24, 48 and 72h of exposure to the antifungals, the cfu/cm 2 was determined by a vortexing-sonication procedure. AMB reduced biofilm viable cells attached to PTFE and titanium by ≥99% and AND by 89.3% on PTFE and 96.8% on titanium. The AMB+AND combination was less active than AMB alone, both on PTFE (decrease of cfu/cm 2 3.09 Log 10 vs. 1.08 when combined) and titanium (4.51 vs. 1.53 when combined), being the interaction irrelevant on both surfaces. AMB is more active than AND against C. tropicalis biofilms. Yeast killing rates are higher on titanium than on PTFE surfaces. The combination of AMB plus AND is less effective than AMB alone on both surfaces. Copyright © 2017 Asociación Española de Micología. Publicado por Elsevier España, S.L.U. All rights reserved.
Tribological interaction between polytetrafluoroethylene and silicon oxide surfaces
DOE Office of Scientific and Technical Information (OSTI.GOV)
Uçar, A.; Çopuroğlu, M.; Suzer, S., E-mail: suzer@fen.bilkent.edu.tr
2014-10-28
We investigated the tribological interaction between polytetrafluoroethylene (PTFE) and silicon oxide surfaces. A simple rig was designed to bring about a friction between the surfaces via sliding a piece of PTFE on a thermally oxidized silicon wafer specimen. A very mild inclination (∼0.5°) along the sliding motion was also employed in order to monitor the tribological interaction in a gradual manner as a function of increasing contact force. Additionally, some patterns were sketched on the silicon oxide surface using the PTFE tip to investigate changes produced in the hydrophobicity of the surface, where the approximate water contact angle was 45°more » before the transfer. The nature of the transferred materials was characterized by X-ray photoelectron spectroscopy (XPS) and scanning electron microscopy (SEM). XPS results revealed that PTFE was faithfully transferred onto the silicon oxide surface upon even at the slightest contact and SEM images demonstrated that stable morphological changes could be imparted onto the surface. The minimum apparent contact pressure to realize the PTFE transfer is estimated as 5 kPa, much lower than reported previously. Stability of the patterns imparted towards many chemical washing processes lead us to postulate that the interaction is most likely to be chemical. Contact angle measurements, which were carried out to characterize and monitor the hydrophobicity of the silicon oxide surface, showed that upon PTFE transfer the hydrophobicity of the SiO{sub 2} surface could be significantly enhanced, which might also depend upon the pattern sketched onto the surface. Contact angle values above 100° were obtained.« less
Paloma, V; Lasso, J M; Bazán, A; Serra, J M
1999-09-01
We have done an experimental study in lambs in which we investigated the influence of flow rate on free microvascular flaps using polytetrafluoroethylene (PTFE) vascular grafts. We set up five surgical groups in which blood flow was progressively increased through the PTFE vascular graft. In group I (venous autograft) we observed just one vascular thrombosis which was located at the site of the anastomosis. In group II (PTFE 3 x 10 mm) all the microvascular flaps became necrosed after the third postoperative day. In group III (PTFE 3 x 10 mm) necrosis also developed in all cases, but the anastomoses remained permeable no longer than eight days. In group IV (3 x 15 mm) the permeability in the microvascular free flaps was about 40% after 21 days, and in group V (3 x 10 mm) it reached 70%. To match graft flow rates with flap survival we did a regression analysis of flow rates for groups II, III, and V and the corresponding survival periods for the flaps. There was a clear and highly significant relationship (r = 0.717, p = 0.0001). In conclusion, it is necessary to maintain blood flow through the prosthesis at a rate higher than the thrombogenic threshold. When the flow rate in the vessels through the PTFE grafts was higher, the viability of the flaps was better. The ideal surgical technique should always be based on an arteriovenous fistula distal to the PTFE vascular graft. It is necessary to maintain blood flow through a prosthesis at a rate higher than the thrombogenic threshold.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-18
... (``PTFE resin'') from Italy would likely lead to a continuation or recurrence of dumping and material... initiation of the third sunset review of the antidumping duty order on PTFE resin from Italy, pursuant to...
ENVIRONMENTALLY-BENIGN POLYTETRAFLUOROETHYLENE (PTFE) COATINGS FOR MOLD RELEASE - PHASE II
GVD proposes to develop high performance, volatile organic compound (VOC)-free and perfluorooctanoic acid (PFOA)-free, non-stick mold release coatings based on its novel polytetrafluoroethylene (PTFE) fluoropolymer technology. Most commercial mold release agents make use of...
Wu, Donghai; Lu, Guanghua; Zhang, Ran; Lin, Qiuhong; Yan, Zhenhua; Liu, Jianchao; Li, Yi
2015-10-01
Combination of ozone together with electrolysis (ozone-electrolysis) is a promising wastewater treatment technology. This work investigated the potential use of carbon nanotube (CNT)-based gas diffusion cathode (GDC) for ozone-electrolysis process employing hydroxyl radicals (·OH) production as an indicator. Compared with conventional active carbon (AC)-polytetrafluoroethylene (PTFE) and carbon black (CB)-PTFE cathodes, the production of ·OH in the coupled process was improved using CNTs-PTFE GDC. Appropriate addition of acetylene black (AB) and pore-forming agent Na2SO4 could enhance the efficiency of CNTs-PTFE GDC. The optimum GDC composition was obtained by response surface methodology (RSM) analysis and was determined as CNTs 31.2 wt%, PTFE 60.6 wt%, AB 3.5 wt%, and Na2SO4 4.7 wt%. Moreover, the optimized CNT-based GDC exhibited much more effective than traditional Ti and graphite cathodes in Acid Orange 7 (AO7) mineralization and possessed the desirable stability without performance decay after ten times reaction. The comparison tests revealed that peroxone reaction was the main pathway of ·OH production in the present system, and cathodic reduction of ozone could significantly promote ·OH generation. These results suggested that application of CNT-based GDC offers considerable advantages in ozone-electrolysis of organic wastewater.
Tissue response to peritoneal implants
NASA Technical Reports Server (NTRS)
Picha, G. J.
1980-01-01
Peritoneal implants were fabricated from poly 2-OH, ethyl methacrylate (HEMA), polyetherurethane (polytetramethylene glycol 1000 MW, 1,4 methylene disocynate, and ethyl diamine), and untreated and sputter treated polytetrafluoroethylene (PTFE). The sputter treated PTFE implants were produced by an 8 cm diameter argon ion source. The treated samples consisted of ion beam sputter polished samples, sputter etched samples (to produce a microscopic surface cone texture) and surface pitted samples (produced by ion beam sputtering to result in 50 microns wide by 100 microns deep square pits). These materials were implanted in rats for periods ranging from 30 minutes to 14 days. The results were evaluated with regard to cell type and attachment kinetics onto the different materials. Scanning electron microscopy and histological sections were also evaluated. In general the smooth hydrophobic surfaces attracted less cells than the ion etched PTFE or the HEMA samples. The ion etching was observed to enhance cell attachment, multinucleated giant cell (MNGC) formation, cell to cell contact, and fibrous capsule formation. The cell responsed in the case of ion etched PTFE to an altered surface morphology. However, equally interesting was the similar attachment kinetics of HEMA verses the ion etched PTFE. However, HEMA resulted in a markedly different response with no MNGC's formation, minimal to no capsule formation, and sample coverage by a uniform cell layer.
Crystal, Matthew A; Morgan, Gareth J; Danon, Saar; Gray, Robert G; Gruenstein, Daniel H; Gordon, Brent M; Goldstein, Bryan H
2018-01-01
Balloon-expandable stents, implanted in infants and children with congenital heart disease (CHD), often require redilation to match somatic growth. Small diameter stents may eventually require longitudinal surgical transection to prevent iatrogenic vascular stenosis. Intentional transcatheter stent fracture (TSF) is an emerging alternative approach to stent transection, but little is known about the optimal stent substrate and best protocol to improve the likelihood of successful TSF. Bench testing was performed with a stent dilation protocol. After recording baseline characteristics, stents were serially or directly dilated using ultra-high-pressure balloons (UHPB) until fracture occurred or further stent dilation was not possible. Stent characteristics recorded were as follows: cell design, metallurgy, mechanism, and uniformity of fracture. Stents tested included bare-metal coronary stents, premounted small diameter stents, and ePTFE-covered small diameter premounted stents. Ninety-four stents representing 9 distinct models were maximally dilated, with 80 (85%) demonstrating evidence of fracture. Comprehensive fracture details were recorded in 64 stents: linear and complete in 34/64 stents (53.1%), linear and incomplete in 9/64 stents (14.1%), transverse/complex and complete in 6/64 stents (9.4%), and transverse/complex and incomplete in 15/64 stents (23.4%). Stent fracture was not accomplished in some stent models secondary to significant shortening, i.e., "napkin-ring" formation. Serial dilation resulted in evidence of fracture in 62/67 (92.5%) stents compared with 18/27 (66.7%) stents in the direct dilation group (p = 0.003). Intentional TSF is feasible in an ex vivo model. Serial dilation more reliably expanded the stent and allowed for ultimate stent fracture, whereas direct large diameter dilation of stents was more likely to generate a "napkin-ring" configuration, which may be more resistant to fracture. In vivo animal and human testing is necessary to better understand the response to attempted TSF for newly developed stents as well as those currently in use.
Jin, Qiaofeng; Kang, Shih-Tsung; Chang, Yuan-Chih; Zheng, Hairong; Yeh, Chih-Kuang
2016-09-01
Nanoscale gas bubbles residing on a macroscale hydrophobic surface have a surprising long lifetime (on the order of days) and can serve as cavitation nuclei for initiating inertial cavitation (IC). Whether interfacial nanobubbles (NBs) reside on the infinite surface of a hydrophobic nanoparticle (NP) and could serve as cavitation nuclei is unknown, but this would be very meaningful for the development of sonosensitive NPs. To address this problem, we investigated the IC activity of polytetrafluoroethylene (PTFE) NPs, which are regarded as benchmark superhydrophobic NPs due to their low surface energy caused by the presence of fluorocarbon. Both a passive cavitation detection system and terephthalic dosimetry was applied to quantify the intensity of IC. The IC intensities of the suspension with PTFE NPs were 10.30 and 48.41 times stronger than those of deionized water for peak negative pressures of 2 and 5MPa, respectively. However, the IC activities were nearly completely inhibited when the suspension was degassed or ethanol was used to suspend PTFE NPs, and they were recovered when suspended in saturated water, which may indicates the presence of interfacial NBs on PTFE NPs surfaces. Importantly, these PTFE NPs could sustainably initiate IC for excitation by a sequence of at least 6000 pulses, whereas lipid microbubbles were completely depleted after the application of no more than 50 pulses under the same conditions. The terephthalic dosimetry has shown that much higher hydroxyl yields were achieved when PTFE NPs were present as cavitation nuclei when using ultrasound parameters that otherwise did not produce significant amounts of free radicals. These results show that superhydrophobic NPs may be an outstanding candidate for use in IC-related applications. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Zandona, Philip
Solid lubrication of space-borne mechanical components is essential to their survival and the continued human exploration of space. Recent discoveries have shown that PTFE when blended with alumina nanofillers exhibits greatly improved physical performance properties, with wear rates being reduced by several orders of magnitude. The bulk processes used to produce the PTFE-alumina blends are limiting. Co-sputter deposition of PTFE and a filler material overcomes several of these limitations by enabling the reduction of particle size to the atomic level and also by allowing for the even coating of the solid lubricant on relatively large areas and components. The goal of this study was to establish a baseline performance of the sputtered PTFE films as compared to the bulk material, and to establish deposition conditions that would result in the most bulk-like film possible. In order to coax change in the structure of the sputtered films, sputtering power and deposition temperature were increased independently. Further, post-deposition annealing was applied to half of the deposited film in an attempt to affect change in the film structure. Complications in the characterization process due to increasing film thickness were also examined. Bulk-like metrics for characterization processes the included Fourier transform infrared spectroscopy (FTIR), X-ray spectroscopy (XPS), nanoindentation via atomic force microscopy, and contact angle of water on surface measurements were established. The results of the study revealed that increasing sputtering power and deposition temperature resulted in an increase in the similarity between the fluorocarbon films and the bulk PTFE, at a cost of affecting the potential of the film thicknesses, either by affecting the deposition process directly, or by decreasing the longevity of the sputtering targets.
Kim, Young-Suk; Wagner, Richard K.; Lopez, Danielle
2012-01-01
From a developmental framework, relations among list reading fluency, oral and silent reading fluency, listening comprehension, and reading comprehension might be expected to change as children’s reading skills develop. We examined developmental relations among these constructs in a latent-variable longitudinal study of first- and second-grade students. Results showed that list reading fluency was uniquely related to reading comprehension in grade one, but not in grade two after accounting for text reading fluency (oral or silent) and listening comprehension. In contrast, text reading fluency was uniquely related to reading comprehension in grade two, but not in grade one, after accounting for list reading fluency and listening comprehension. When oral and silent reading fluency were compared, oral reading fluency was uniquely related to reading comprehension after accounting for silent reading fluency in grade one whereas in grade two, silent reading fluency was uniquely related to reading comprehension after accounting for oral reading fluency. PMID:22726256
ERIC Educational Resources Information Center
Cribbs, Aimee M.
2013-01-01
This study focused on the relationships between educator reading fluency constructs, reading fluency instruction and oral reading fluency assessment. Survey responses from sixty-six elementary educators in rural and urban north Georgia were analyzed to reach an understanding of why educators are likely to equate reading fluency with reading fast…
Pathways From Toddler Information Processing to Adolescent Lexical Proficiency.
Rose, Susan A; Feldman, Judith F; Jankowski, Jeffery J
2015-01-01
This study examined the relation of 3-year core information-processing abilities to lexical growth and development. The core abilities covered four domains-memory, representational competence (cross-modal transfer), processing speed, and attention. Lexical proficiency was assessed at 3 and 13 years with the Peabody Picture Vocabulary Test (PPVT) and verbal fluency. The sample (N = 128) consisted of 43 preterms (< 1750 g) and 85 full-terms. Structural equation modeling indicated concurrent relations of toddler information processing and language proficiency and, independent of stability in language, direct predictive links between (a) 3-year cross-modal ability and 13-year PPVT and (b) 3-year processing speed and both 13-year measures, PPVT and verbal fluency. Thus, toddler information processing was related to growth in lexical proficiency from 3 to 13 years. © 2015 The Authors. Child Development © 2015 Society for Research in Child Development, Inc.
NASA Astrophysics Data System (ADS)
Hopp, Bela; Revesz, K.; Bor, Zsolt
1998-07-01
A successful enhancement of sticking of PTFE is demonstrated using ArF excimer laser irradiation in the presence of novel photoreagents. The applied laser fluence was very low at the sample - photoreagent liquid interface compared to the energy density applied in earlier investigations. After the treatment the PTFE films were glued by epoxy resin. It was found that at low doses the tensile strength of the sticking increased rapidly with the UV pulse number and the reached a saturation value, which was 6.66 MPa for triethylamine, 5.56 MPa in the case of 1,2-diaminoethane and 4.64 MPa for triethylene-tetramine. These are around two hundred times higher than the value of the untreated surface. It was found that this procedure makes the metallization and painting of PTFE surface also possible. A photoinduced electron transfer mechanism was suggested to describe the photoreaction, which is responsible for the increase of adhesion features on PTFE surface.
Constitutive modeling of shock response of PTFE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brown, Eric N; Reanyansky, Anatoly D; Bourne, Neil K
2009-01-01
The PTFE (polytetrafluoroethylene) material is complex and attracts attention of the shock physics researchers because it has amorphous and crystalline components. In turn, the crystalline component has four known phases with the high pressure transition to phase III. At the same time, as has been recently studied using spectrometry, the crystalline region is growing with load. Stress and velocity shock-wave profiles acquired recently with embedded gauges demonstrate feature that may be related to impedance mismatches between the regions subjected to some transitions resulting in density and modulus variations. We consider the above mentioned amorphous-to-crystalline transition and the high pressure Phasemore » II-to-III transitions as possible candidates for the analysis. The present work utilizes a multi-phase rate sensitive model to describe shock response of the PTFE material. One-dimensional experimental shock wave profiles are compared with calculated profiles with the kinetics describing the transitions. The objective of this study is to understand the role of the various transitions in the shock response of PTFE.« less
NASA Astrophysics Data System (ADS)
Nosaka, Masataka; Oike, Mamoru; Kikuchi, Masataka; Kamijo, Kenjiro; Tajiri, Masanori
1993-07-01
The tribo characteristics of self-lubricating 40-mm-bore ball bearings with a retainer of glass cloth-polytetrafluoroethylene (PTFE) laminate, which has elliptical pockets with a large pocket clearance, were tested under thrust loads at speeds up to 50,000 rpm, 2 million DN, in liquid hydrogen (LH2) and in liquid nitrogen (LN2). During testing, the bearing torque, outer-race temperature, and electric resistance between the inner and outer races were monitored to verify the formation and rupture of a PTFE transfer film. Testing showed that the bearings having the elliptical retainer pockets were superior to the conventional bearings with circular pockets. It was determined that, at the maximum inner race spinning velocity of about 5 m/s, a PTFE transfer film could sustain the maximum Hertz stress, up to about 2000 N/sq mm, in LH2, without severe film rupture resulting in bearing seizure. In LN2, the critical load capacity of PTFE transfer film with bearing seizure was about 2700 N/sq mm.
NASA Astrophysics Data System (ADS)
Qian, Yingjia; Chi, Lina; Zhou, Weili; Yu, Zhenjiang; Zhang, Zhongzhi; Zhang, Zhenjia; Jiang, Zheng
2016-01-01
Surface hydrophilic modification of polymer ultrafiltration membrane using metal oxide represents an effective yet highly challenging solution to improve water flux and antifouling performance. Via plasma-enhanced graft of poly acryl acid (PAA) prior to coating TiO2, we successfully fixed TiO2 functional thin layer on super hydrophobic polytetrafluoroethylene (PTFE) ultrafiltration (UF) membranes. The characterization results evidenced TiO2 attached on the PTFE-based UF membranes through the chelating bidentate coordination between surface-grafted carboxyl group and Ti4+. The TiO2 surface modification may greatly reduce the water contact angle from 115.8° of the PTFE membrane to 35.0° without degradation in 30-day continuous filtration operations. The novel TiO2/PAA/PTFE membranes also exhibited excellent antifouling and self-cleaning performance due to the intrinsic hydrophilicity and photocatalysis properties of TiO2, which was further confirmed by the photo-degradation of MB under Xe lamp irradiation.
NASA Astrophysics Data System (ADS)
Zhang, Junmin; Chen, Zhang
2008-10-01
A new magnetic hydro-dynamics model for nozzle arc emphasizing the interaction of arc with PTFE (polytetrafluorethylene) vapour is established based on the conservation equations. The interruption of auto-expansion circuit breaker is simulated numerically by finite element method and the influence of PTFE vapour on the arc is analysed with this model. The results reveal that the flow field inside the arc chamber is determined by the arc current, the arcing time, the nozzle arc and the clogging of its thermal boundary. The establishment of quenching pressure relies on both SF6 gas and PTFE vapour that absorbed arc energy in the nozzle. The PTFE vapour leads to an increase in the pressure of nozzle arc obviously, and a decrease in the temperature of arc. But it enhances the temperature of arc at zero current and slows down the decreasing rate of arc temperature as the current decreases.
Putting the Fun Back into Fluency Instruction
ERIC Educational Resources Information Center
Cahill, Mary Ann; Gregory, Anne E.
2011-01-01
Based on recent research in fluency instruction, the authors present a scenario in which a teacher focuses her fluency instruction on authentic fluency tasks based in performance. Beginning with establishing a student-friendly definition of fluency and culminating with student engagement in fun fluency activities, this article explores the…
NASA Astrophysics Data System (ADS)
Wang, Haiyan; Wang, Weizong; Yan, Joseph D.; Qi, Haiyang; Geng, Jinyue; Wu, Yaowu
2017-10-01
Ablation-controlled plasmas have been used in a range of technical applications where local thermodynamic equilibrium (LTE) is often violated near the wall due to the strong cooling effect caused by the ablation of wall materials. The thermodynamic and transport properties of ablated polytetrafluoroethylene (PTFE) vapor, which determine the flowing plasma behavior in such applications, are calculated based on a two-temperature model at atmospheric pressure. To our knowledge, no data for PTFE have been reported in the literature. The species composition and thermodynamic properties are numerically determined using the two-temperature Saha equation and the Guldberg-Waage equation according to van de Sanden et al’s derivation. The transport coefficients, including viscosity, thermal conductivity and electrical conductivity, are calculated with the most recent collision interaction potentials using Devoto’s electron and heavy-particle decoupling approach but expanded to the third-order approximation (second-order for viscosity) in the frame of the Chapman-Enskog method. Results are computed for different degrees of thermal non-equilibrium, i.e. the ratio of electron to heavy-particle temperatures, from 1 to 10, with electron temperature ranging from 300 to 40 000 K. Plasma transport properties in the LTE state obtained from the present work are compared with existing published results and the causes for the discrepancy analyzed. The two-temperature plasma properties calculated in the present work enable the modeling of wall ablation-controlled plasma processes.
Souza, Sérgio L S; Macedo, Guilherme O; Silveira E Souza, Adriana M M; Taba, Mário; Novaes, Arthur B; Oliver, Constance; Jamur, Maria C; Correa, Vani M A
2013-10-01
Previous studies have shown that there is a relationship between periodontal disease and the distribution of collagen fibers. This study evaluated the distribution of collagen types I and III in regenerated bone and periodontal ligament, comparing them to the tissues near the regenerated area and to the healthy periodontium. In the third (P3) and fourth (P4) mandibular premolars of 5 healthy mongrel dogs, bilaterally, buccal class 2 furcation lesions were surgically created and chronified for 3 weeks. After that, full flaps were elevated and expanded polytetrafluoroethylene (e-PTFE) membranes were adapted, sutured and recovered by the flaps. Two weeks after surgery, two membranes on the same side were removed and the other membranes were removed four weeks after surgery. The dogs were euthanized at 12 weeks following placement of the e-PTFE membranes. P3 and P4 teeth as well as the second premolars (healthy control teeth) and their periodontal tissues were removed and histologically processed for Collagen Quantification (COLQ). The amount of type III collagen was higher in native bone compared to the regenerated area. For periodontal ligament, COLQ for type I collagen showed statistically significant differences (Tukeys's Multiple Comparison, p⟨0.05) between the regenerated groups and the control group. These differences were not found for type III COLQ. There are significant differences in collagen distribution among the regenerated, native and control tissues. Membrane removal 2 or 4 weeks postoperatively did not influence the collagen composition.
Cerebral blood flow associated with creative performance: a comparative study.
Chávez-Eakle, Rosa Aurora; Graff-Guerrero, Ariel; García-Reyna, Juan-Carlos; Vaugier, Víctor; Cruz-Fuentes, Carlos
2007-11-15
Creativity is important for social survival and individual wellbeing; science, art, philosophy and technology have been enriched and expanded by this trait. To our knowledge this is the first study probing differences in brain cerebral blood flow (CBF) between highly creative individuals (scientists and/or artists socially recognized for their contributions to their fields with creativity indexes corresponding to the 99% percentile) and average control subjects while performing a verbal task from the Torrance Tests of Creative Thinking. Additionally, we correlated CBF with creativity dimensions such as fluency, originality and flexibility. Subjects with a high creative performance showed greater CBF activity in right precentral gyrus, right culmen, left and right middle frontal gyrus, right frontal rectal gyrus, left frontal orbital gyrus, and left inferior gyrus (BA 6, 10, 11, 47, 20), and cerebellum; confirming bilateral cerebral contribution. These structures have been involved in cognition, emotion, working memory, and novelty response. The score on the three creativity dimensions--fluency, originality, and flexibility--correlated with CBF activation in right middle frontal gyrus and right rectal gyrus (Brodmann Area 6, 11). Moreover, fluency and flexibility strongly correlated with CBF in left inferior frontal gyrus and originality correlated with CBF in left superior temporal gyrus and cerebellar tonsil. These findings suggest an integration of perceptual, volitional, cognitive and emotional processes in creativity. The higher CBF found in particular brain regions of highly creative individuals during the performance of a creative task provides evidence of a specific neural network related to the creative process.
Mahmood, Zanjbeel; Burton, Cynthia Z; Vella, Lea; Twamley, Elizabeth W
2018-04-13
Neuropsychological abilities may underlie successful performance of everyday functioning and social skills. We aimed to determine the strongest neuropsychological predictors of performance-based functional capacity and social skills performance across the spectrum of severe mental illness (SMI). Unemployed outpatients with SMI (schizophrenia, bipolar disorder, or major depression; n = 151) were administered neuropsychological (expanded MATRICS Consensus Cognitive Battery), functional capacity (UCSD Performance-Based Skills Assessment-Brief; UPSA-B), and social skills (Social Skills Performance Assessment; SSPA) assessments. Bivariate correlations between neuropsychological performance and UPSA-B and SSPA total scores showed that most neuropsychological tests were significantly associated with each performance-based measure. Forward entry stepwise regression analyses were conducted entering education, diagnosis, symptom severity, and neuropsychological performance as predictors of functional capacity and social skills. Diagnosis, working memory, sustained attention, and category and letter fluency emerged as significant predictors of functional capacity, in a model that explained 43% of the variance. Negative symptoms, sustained attention, and letter fluency were significant predictors of social skill performance, in a model explaining 35% of the variance. Functional capacity is positively associated with neuropsychological functioning, but diagnosis remains strongly influential, with mood disorder participants outperforming those with psychosis. Social skill performance appears to be positively associated with sustained attention and verbal fluency regardless of diagnosis; however, negative symptom severity strongly predicts social skills performance. Improving neuropsychological functioning may improve psychosocial functioning in people with SMI. Published by Elsevier Ltd.
EPR/PTFE dosimetry for test reactor environments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vehar, D.W.; Griffin, P.J.; Quirk, T.J.
2011-07-01
The use of Electron Paramagnetic Resonance (EPR) spectroscopy with materials such as alanine is well established as a technique for measurement of ionizing radiation absorbed dose in photon and electron fields such as Co-60, high-energy bremsstrahlung and electron-beam fields [1]. In fact, EPR/Alanine dosimetry has become a routine transfer standard for national standards bodies such as NIST and NPL. In 1992 the Radiation Metrology Laboratory (RML) at Sandia National Laboratories implemented EPR/Alanine capabilities for use in routine and calibration activities at its Co-60 and pulsed-power facilities. At that time it also investigated the usefulness of the system for measurement ofmore » absorbed dose in the mixed neutron/photon environments of reactors such as the Sandia Pulsed Reactor and the Annular Core Research Reactor used for hardness testing of electronics. The RML concluded that the neutron response of alanine was a sufficiently high fraction of the overall dosimeter response that the resulting uncertainties in the photon dose would be unacceptably large for silicon-device testing. However, it also suggested that non-hydrogenous materials such as polytetrafluoroethylene (PTFE) would exhibit smaller neutron response and might be useful in mixed environments. Preliminary research with PTFE in photon environments indicated considerable promise, but further development was not pursued at that time. Because of renewed interest in absorbed dose measurements that could better define the individual contributions of photon and neutron components to the overall dose delivered to a test object, the RML has re-initiated the development of an EPR/PTFE dosimetry system. This effort consists of three stages: 1) Identification of PTFE materials that may be suitable for dosimetry applications. It was speculated that the inconsistency of EPR signatures in the earlier samples may have been due to variability in PTFE manufacturing processes. 2) Characterization of dosimetry in photon-only environments. This is necessary to establish requirements for sample preparation, operating parameters and limitations for use in well-defined and predictable environments prior to deployment in the less well-defined mixed environments of test reactors. 3) Characterization of the EPR responses obtained with PTFE in mixed neutron/photon fields. This includes evaluation of the neutron and photon contributions to response, determination of applicable of neutron fluence and photon dose ranges. This paper presents a summary of the research, a description of the EPR/PTFE dosimetry system, and recommendations for preparation and fielding of the dosimetry in photon and mixed neutron/photon environments. (authors)« less
Flores Carmona, Diana Yamel; Alonso Lárraga, Juan Octavio; Hernández Guerrero, Angélica; Ramírez Solís, Mauro Eduardo
2016-05-01
Drainage with metallic stents is the treatment of choice in malignant obstructive jaundice. Technical and clinical success with metallic stents is obtained in over 90% and 80% of cases, respectively. There are self-expandable metallic stents designed to increase permeability. The aim of this study was to describe the results obtained with totally covered self-expandable and uncovered self-expandable metallic stents in the palliative treatment of malignant biliary obstruction. Sixty eight patients with malignant obstructive jaundice secondary to pancreatobiliary or metastatic disease not amenable to surgery were retrospectively included. Two groups were created: group A (covered self-expandable metallic stents) (n = 22) and group B (uncovered self-expandable metallic stents) (n = 46). Serum total bilirubin, direct bilirubin, alkaline phosphatase and gamma glutamyl transferase levels decreased in both groups and no statistically significant difference was detected (p = 0.800, p = 0.190, p = 0.743, p = 0.521). Migration was greater with covered stents but it was not statistically significant either (p = 0.101). Obstruction was greater in the group with uncovered stents but it was not statistically significant either (p = 0.476). There are no differences when using covered self-expandable stents or uncovered self-expandable stents in terms of technical and clinical success or complications in the palliative treatment of malignant obstructive jaundice.
NASA Astrophysics Data System (ADS)
Hodges, James M.
Emerging applications and fundamental studies require nanomaterials with increasingly sophisticated architectures that have precise composition, morphology, and crystal structure. Colloidal nanochemistry has emerged as one of the most effective methods for generating high quality, monodisperse nanoparticles with diverse structural features and highly complex geometries. These wet-chemical approaches offer an array of synthetic levers that can be used to tailor nanoparticles for targeted applications, and deliver solution-dispersible solids that are easily integrated onto device architectures. Additionally, colloidal nanoparticles can be used as building blocks for constructing periodic superlattices and multicomponent hybrid nanoparticles, which offer unique properties that can support next-generation technologies. As the applications for colloidal nanoparticles continue to expand, the architectural and compositional requirements for these materials are becoming increasingly rigid. Conventional colloidal methods are effective for generating diverse nanoparticle systems, but rely on complex nucleation and growth processes, which are often poorly understood and difficult to control in dynamic reaction environments. For these reasons, there are a number of high profile nanoparticle targets that remain out of reach. Accordingly, new approaches are needed that can circumvent these synthetic bottlenecks and narrow the growing disconnect between nano-design and synthetic capability. In this dissertation, I present several colloidal strategies for engineering synthetically challenging nanomaterials using multistep reaction sequences that, in many ways, parallel the total-synthesis framework that organic chemists use to access complex molecules. A variety of approaches are discussed, including nanoscale ion exchange transformations and seeded-growth protocol for constructing multicomponent hybrid nanoparticles. First, I demonstrate that solution-mediated anion and cation exchange can be integrated into one multistep reaction sequence, which leads to a complete material transformation of a pre-synthesized nanotemplate. Importantly, although the final product does not contain any of the original elements, the morphology is retained, effectively decoupling morphology and composition control. Next, I demonstrate that both anion and cation sublattice features of preformed Cu2-xS nanocrystals can be retained during cation exchange with Co2+ and Mn2+, yielding wurtzite-type CoS and MnS polymorphs that are metastable in bulk systems. This study was enabled by new cation exchange chemistry with previously unexplored 3d transition metal systems, and offers new guidelines for predictably targeting sublattice features in colloidal nanomaterials. To conclude the dissertation, I offer two studies investigating the seeded-growth synthesis of three-component Ag-Pt-Fe3O4 heterotrimer nanoparticles, which are generated by adding a Ag domain to preformed Pt-Fe 3O4 heterodimers. First, to gain access to the alternate Pt-Fe3O4-Ag configuration, I demonstrate that a thin iron oxide shell can be applied to the Pt surface of the Pt-Fe3O 4 seeds, which acts as a solid-state protecting group that can direct Ag growth onto the Fe3O4 domain, producing the otherwise inaccessible Pt-Fe3O4-Ag architecture. This strategy is inspired by similar techniques used in organic synthesis, and represents an important addition to the 'total synthesis toolbox' used to construct colloidal hybrid nanoparticles. Finally, I offer an in-depth microscopic investigation that probes the chemoselective addition of Ag to Pt-Fe 3O4 to form the Ag-Pt-Fe3O4 heterotrimer product. This study reveals that Ag indiscriminately nucleates on both the Pt and Fe3O4 domains of the Pt-Fe3O 4 seeds during the early stages of the reaction, followed by a surface-mediated coalescence of Ag onto the Pt domain to yield the Ag-Pt-Fe3O 4 configuration. The mechanistic insights gained in this work provide new design criteria for synthesizing multicomponent hybrid nanoparticle systems with targeted configurations.
78 FR 59653 - Notice of Scope Rulings
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-27
... Administration, U.S. Department of Commerce, 14th Street and Constitution Avenue NW., Washington, DC 20230... polytetrafluoroethylene (PTFE) resin products made from raw, unfilled PTFE powder from Russia and the People's Republic of... the antidumping duty order; April 26, 2013 (preliminary). People's Republic of China A-570-967 and C...
Removal of I, Rn, Xe and Kr from off gas streams using PTFE membranes
Siemer, Darryl D.; Lewis, Leroy C.
1990-01-01
A process for removing I, R, Xe and Kr which involves the passage of the off gas stream through a tube-in-shell assembly, whereby the tubing is a PTFE membrane which permits the selective passages of the gases for removing and isolating the gases.
Removal of I, Rn, Xe and Kr from off gas streams using PTFE membranes
Siemer, Darryl D.; Lewis, Leroy C.
1990-08-07
A process for removing I, R, Xe and Kr which involves the passage of the off gas stream through a tube-in-shell assembly, whereby the tubing is a PTFE membrane which permits the selective passages of the gases for removing and isolating the gases.
Novel Polymeric Dielectric Materials for the Additive Manufacturing of Microwave Devices
NASA Astrophysics Data System (ADS)
O'Keefe, Shamus E.
The past decade has seen a rapid increase in the deployment of additive manufacturing (AM) due to the perceived benefits of lower cost, higher quality, and a smaller environmental footprint. And while the hardware behind most of AM processes is mature, the study and development of material feedstock(s) are in their infancy, particularly so for niche areas. In this dissertation, we look at novel polymeric materials to support AM for microwave devices. Chapter 1 provides an overview of the benefits of AM, followed by the specific motivation for this work, and finally a scope defining the core objectives. Chapter 2 delves into a higher-level background of dielectric theory and includes a brief overview of the two common dielectric spectroscopy techniques used in this work. The remaining chapters, summarized below, describe experiments in which novel polymeric materials were developed and their microwave dielectric properties measured. Chapter 3 describes the successful synthesis of polytetrafluroethylene (PTFE)/polyacrylate (PA) core-shell nanoparticles and their measured microwave dielectric properties. PTFE/PA core-shell nanoparticles with spherical morphology were successfully made by aerosol deposition followed by a brief annealing. The annealing temperature is closely controlled to exceed the glass transition (Tg) of the PA shell yet not exceed the Tg of the PTFE core. Furthermore, the annealing promotes coalescence amongst the PA shells of neighboring nanoparticles and results in the formation of a contiguous PA matrix that has excellent dispersion of PTFE cores. The measured dielectric properties agree well with theoretical predictions and suggest the potential of this material as a feedstock for AM microwave devices. Chapter 4 delves into the exploration of various polyimide systems with the aim of replacing the PA in the previously studied PTFE/PA core-shell nanoparticles. Fundamental relationships between polymer attributes (flexibility/rigidity and functional groups) and dielectric properties were explored. The results indicate that backbone rigidity and the inclusion of fluorine lead to excellent dielectric properties, however, often at the expense of mechanical properties. Chapter 5 explores the optimization of PTFE core-shell nanoparticles via a novel PTFE/polyimide (PI) core-shell nanoparticle. PTFE/PI core-shell nanoparticles were synthesized via electrostatic interaction between the PTFE cores and a PI precursor, poly(amic) acid salt (PAAS). The PAAS is converted to PI by thermal imidization. The PI has properties superior to those of PA for microwave applications and the results suggest the promise of PTFE/PI core-shell nanoparticles for use in AM of microwave devices. Chapter 6 describes the first report of on actively-tunable microwave substrate made possible by a semiconducting polymer composite blend. The composite blend is comprised of poly(3-hexylthiophene) (P3HT) as the semiconducting polymer and [6,6]-Phenyl C61 butyric acid methyl ester (PCBM) while the remainder of the composite is comprised of a low dielectric constant polymer polydimethylsiloxane (PDMS). When subjected to photo excitation (white light, spectrum centered at 532 nm), the composite exhibits a tunability of the permittivity up to 20%. The results suggest strong promise for the use of semiconducting polymers in actively-tunable microwave devices. Finally, Chapter 7 presents a summary of the salient conclusions of the reported studies. The chapter concludes with a few brief remarks of my personal experience as a non-traditional student and the challenges therein.
Investigating the importance of flow when utilizing hyaluronan scaffolds for tissue engineering.
Donegan, Gail C; Hunt, John A; Rhodes, Nicholas
2010-02-01
Esterified hyaluronan scaffolds offer significant advantages for tissue engineering. They are recognized by cellular receptors, interact with many other extracellular matrix proteins and their metabolism is mediated by intrinsic cellular pathways. In this study differences in the viability and structural integrity of vascular tissue models cultured on hyaluronan scaffolds under laminar flow conditions highlighted potential differences in the biodegradation kinetics, processes and end-products, depending on the culture environment. Critical factors are likely to include seeding densities and the duration and magnitude of applied biomechanical stress. Proteomic evaluation of the timing and amount of remodelling protein expression, the resulting biomechanical changes arising from this response and metabolic cell viability assay, together with examination of tissue morphology, were conducted in vascular tissue models cultured on esterified hyaluronan felt and PTFE mesh scaffolds. The vascular tissue models were derived using complete cell sheets derived from harvested and expanded umbilical cord vein cells. This seeding method utilizes high-density cell populations from the outset, while the cells are already supported by their own abundant extracellular matrix. Type I and type IV collagen expression in parallel with MMP-1 and MMP-2 expression were monitored in the tissue models over a 10 day culture period under laminar flow regimes using protein immobilization technologies. Uniaxial tensile testing and scanning electron microscopy were used to compare the resulting effects of hydrodynamic stimulation upon structural integrity, while viability assays were conducted to evaluate the effects of shear on metabolic function. The proteomic results showed that the hyaluronan felt-supported tissues expressed higher levels of all remodelling proteins than those cultured on PTFE mesh. Overall, a 21% greater expression of type I collagen, 24% higher levels of type IV collagen, 24% higher levels of MMP-1 and 34% more MMP-2 were observed during hydrodynamic stress. This was coupled with a loss of structural integrity in these models after the introduction of laminar flow, as compared to the increases in all mechanical properties observed in the PTFE mesh-supported tissues. However, under flow conditions, the hyaluronan-supported tissues showed some recovery of the viability originally lost during static culture conditions, in contrast to PTFE mesh-based models, where initial gains were followed by a decline in metabolic viability after applied shear stress. Proteomic, cell viability and mechanical testing data emphasized the need for extended in vitro evaluations to enable better understanding of multi-stage remodelling and reparative processes in tissues cultured on biodegradable scaffolds. This study also highlighted the possibility that in high-density tissue culture with a biodegradable component, dynamic conditions may be more conducive to optimal tissue development than the static environment because they facilitate the efficient removal of high concentrations of degradation end-products accumulating in the pericellular space.
Oral Reading Fluency as a Predictor of Silent Reading Fluency at Secondary and Postsecondary Levels
ERIC Educational Resources Information Center
Seok, Soonhwa; DaCosta, Boaventura
2014-01-01
This research investigated oral reading fluency as a predictor of silent reading fluency at the secondary and postsecondary levels. Several measures were used, including the Gray Oral Reading Test, the Test of Silent Word Reading Fluency, the Test of Silent Contextual Reading Fluency, and the Reading Observation Scale. A total of 223 students…
Segmental liver incarceration through a recurrent incisional lumbar hernia.
Salemis, Nikolaos S; Nisotakis, Konstantinos; Gourgiotis, Stavros; Tsohataridis, Efstathios
2007-08-01
Lumbar hernia is a rare congenital or acquired defect of the posterior abdominal wall. The acquired type is more common and occurs mainly as an incisional defect after flank surgery. Incarceration or strangulation of hernia contents is uncommon. Segmental liver incarceration through a recurrent incisional lumbar defect was diagnosed in a 58 years old woman by magnetic resonance imaging. The patient underwent an open repair of the complicated hernia. An expanded polytetraflouoroethylene (e-PTFE) mesh was fashioned as a sublay prosthesis. She had an uncomplicated postoperative course. Follow-up examinations revealed no evidence of recurrence. Although lumbar hernia rarely results in incarceration or strangulation, early repair is necessary because of the risks of complications and the increasing difficulty in repairment as it enlarges. Surgical repair is often difficult and challenging.
Emotional Intelligence and cognitive abilities - associations and sex differences.
Pardeller, Silvia; Frajo-Apor, Beatrice; Kemmler, Georg; Hofer, Alex
2017-09-01
In order to expand on previous research, this cross-sectional study investigated the relationship between Emotional Intelligence (EI) and cognitive abilities in healthy adults with a special focus on potential sex differences. EI was assessed by means of the Mayer-Salovey-Caruso-Emotional-Intelligence Test (MSCEIT), whereas cognitive abilities were investigated using the Brief Assessment of Cognition in Schizophrenia (BACS), which measures key aspects of cognitive functioning, i.e. verbal memory, working memory, motor speed, verbal fluency, attention and processing speed, and reasoning and problem solving. 137 subjects (65% female) with a mean age of 38.7 ± 11.8 years were included into the study. While males and females were comparable with regard to EI, men achieved significantly higher BACS composite scores and outperformed women in the BACS subscales motor speed, attention and processing speed, and reasoning and problem solving. Verbal fluency significantly predicted EI, whereas the MSCEIT subscale understanding emotions significantly predicted the BACS composite score. Our findings support previous research and emphasize the relevance of considering cognitive abilities when assessing ability EI in healthy individuals.
White matter microstructure integrity in relation to reading proficiency☆.
Nikki Arrington, C; Kulesz, Paulina A; Juranek, Jenifer; Cirino, Paul T; Fletcher, Jack M
2017-11-01
Components of reading proficiency such asaccuracy, fluency, and comprehension require the successful coordination of numerous, yet distinct, cortical regions. Underlying white matter tracts allow for communication among these regions. This study utilized unique residualized tract - based spatial statistics methodology to identify the relations of white matter microstructure integrity to three components of reading proficiency in 49 school - aged children with typically developing phonological decoding skills and 27 readers with poor decoders. Results indicated that measures of white matter integrity were differentially associated with components of reading proficiency. In both typical and poor decoders, reading comprehension correlated with measures of integrity of the right uncinate fasciculus; reading comprehension was also related to the left inferior longitudinal fasciculus in poor decoders. Also in poor decoders, word reading fluency was related to the right uncinate and left inferior fronto - occipital fasciculi. Word reading was unrelated to white matter integrity in either group. These findings expand our knowledge of the association between white matter integrity and different elements of reading proficiency. Copyright © 2017 Elsevier Inc. All rights reserved.
Tringali, Andrea; Blero, Daniel; Boškoski, Ivo; Familiari, Pietro; Perri, Vincenzo; Devière, Jacques; Costamagna, Guido
2014-06-01
Removal of biliary Fully Covered Self Expandable Metal Stents can fail due to stent migration and/or hyperplastic ingrowth/overgrowth. A case series of 5 patients with benign biliary strictures (2 post-cholecystectomy, 2 following liver transplantation and 1 related to chronic pancreatitis) is reported. The biliary stricture was treated by temporary insertion of Fully Covered Self Expandable Metal Stents. Stent removal failed due to proximal stent migration and/or overgrowth. Metal stent removal was attempted a few weeks after the insertion of another Fully Covered Metal Stent into the first one. The inner Fully Covered Self Expandable Metal Stent compressed the hyperplastic tissue, leading to the extraction of both the stents in all cases. Two complications were reported as a result of the attempt to stents removal (mild pancreatitis and self-limited haemobilia). In the present series, the "SEMS in SEMS" technique revealed to be effective when difficulties are encountered during Fully Covered Self Expandable Metal Stents removal. Copyright © 2014 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
Is Oral/Text Reading Fluency a “Bridge” to Reading Comprehension?
Kim, Young-Suk Grace; Park, Chea Hyeong; Wagner, Richard K.
2015-01-01
In the present study we investigated developmental relations among word reading fluency, listening comprehension, and text reading fluency to reading comprehension in a relatively transparent language, Korean. A total of 98 kindergartners and 170 first graders in Korea were assessed on a series of tasks involving listening comprehension, word reading fluency, text reading fluency, and reading comprehension. Results from multigroup structural equation models showed that text reading fluency was a dissociable construct for both kindergartners and first graders. In addition, a developmental pattern emerged: listening comprehension was not uniquely related to text reading fluency for first graders, but not for kindergartners, over and above word reading fluency. In addition, text reading fluency was uniquely related to reading comprehension for kindergartners, but not for first graders, after accounting for word reading fluency and listening comprehension. For first graders, listening comprehension dominated the relations. There were no differences in the pattern of relations for skilled and less skilled readers in first grade. Results are discussed from a developmental perspective for reading comprehension component skills including text reading fluency. PMID:25653474
Hyun, Hyeran; Choi, Sun Young; Kim, Kyung Ah; Ko, Soo Bin
2016-09-01
To estimate the safety and efficacy of percutaneous ePTFE-covered biliary stent placement and the relationship between underlying liver function and stent patency in patients with malignant hilar obstruction. From March 2012 to June 2015, 41 patients [22 females, 19 males; mean age 69.8 (range 34-94) years] with malignant biliary obstruction underwent percutaneous biliary stent placement (31 patients with unilateral, 10 patients with bilateral side-by-side). Cumulative patient survival and stent patency rate curves were derived using the Kaplan-Meier method. A Cox model was used to explore the relationship between liver function and patient survival, and also biliary stent patency. Pearson correlation coefficient was used to analyze the relationship between patient survival and stent patency. Technical success rate was 100 % and clinical success rate was 95 %. During follow-up, four complications occurred (two bilomas and two cases of acute cholecystitis) and were treated successfully with percutaneous drainage. No other complication occurred. Mean serum bilirubin level was 11.34 ± 7.35 mg/dL before drainage and 5.00 ± 4.83 mg/dL 2 weeks after stent placement. The median patent survival duration was 147 days (95 % CI, 69.6-224.4 days). The median stent patency duration was 101 days (95 % CI, 70.0-132.0 days). The cumulative stent patency rates at 1, 3, 6, and 12 months were 97, 57.6, 30.3, and 17.0 %, respectively. Child-Pugh score was correlated significantly with patient survival (P = 0.011) and stent patency (P = 0.007). MELD score was correlated significantly with stent patency (P = 0.044). There was a correlation between patient survival and stent patency (r = 0.778, P < 0.001). Percutaneous placement of ePTFE-covered biliary stent was a safe and an effective method for malignant biliary obstruction. Underlying liver function seemed to be one of the important factors affecting patient survival and stent patency, and stent patency showed statistically significant correlation with patient survival.
Performance of PTFE-lined composite journal bearings
NASA Technical Reports Server (NTRS)
Sliney, H. E.; Williams, F. J.
1982-01-01
Plain cylindrical journal bearings consisting of aramid fiber reinforced epoxy outer shells and glass fiber reinforced PTFE lubricating liners were evaluated. All materials in these bearings are electrically nonconductive; thus eliminating the problem of galvanic corrosion sometimes encountered with metal bearings installed in dissimilar metal mountings. Friction and wear characteristics were determined for loads, temperatures, and oscillating conditions that are typical of current airframe bearing applications. Friction and wear characteristics were found to be compatible with most airframe bearing requirements from -23 C to 121 C. Contamination with MIL H-5606 hydraulic fluid increased wear of the PTFE liners at 121 C, but did not affect the structural integrity of the aramid/epoxy composite.
Compressive Properties of PTFE/Al/Ni Composite Under Uniaxial Loading
NASA Astrophysics Data System (ADS)
Wang, Huai-xi; Li, Yu-chun; Feng, Bin; Huang, Jun-yi; Zhang, Sheng; Fang, Xiang
2017-05-01
To investigate the mechanical properties of pressed and sintered PTFE/Al/Ni (polytetrafluoroethylene/aluminum/nickel) composite, uniaxial quasi-static and dynamic compression experiments were conducted at strain rates from 10-2 to 3 × 103/s. The prepared samples were tested by an electrohydraulic press with 300 kN loading capacity and a split Hopkinson pressure bar (SHPB) device at room temperature. Experimental results show that PTFE/Al/Ni composite exhibits evident strain hardening and strain rate hardening. Additionally, a bilinear relationship between stress and {{log(}}\\dot{ɛ} ) is observed. The experimental data were fit to Johnson-Cook constitutive model, and the results are in well agreement with measured data.
Improved adhesion of Ni films on X-ray damaged polytetrafluoroethylene
NASA Technical Reports Server (NTRS)
Wheeler, D. R.; Pepper, S. V.
1981-01-01
The considered investigation shows that the adhesion of evaporated Ni on polytetrafluoroethylene (PTFE) is enhanced by irradiating the PTFE surface prior to evaporation. Evidence obtained with the aid of X-ray photoelectron spectroscopy is presented concerning the association of the enhanced adhesion with an interfacial chemical reaction. Evaporated Ni clearly adheres better to the X-ray damaged PTFE surface than to the undamaged surface. There is evidence that the improved adhesion is not related to the Ni-C bond, but rather to the NiF2. A possible mechanism which may be consistent with the data is the formation of a F-Ni-C complex, where C is a member of the polymer chain.
Femtosecond laser ablated durable superhydrophobic PTFE sheet for oil/water separation
NASA Astrophysics Data System (ADS)
Li, Wentao; Yang, Qing; Chen, Feng; Yong, Jiale; Fang, Yao; Huo, Jinglan
2017-02-01
Femtosecond laser microfabrication has been attracting increasing interest of researchers in recent years, and been applied on interface science to control the wettability of solid surfaces. Herein, we fabricate a kind of rough microstructures on polytetrafluoroethylene (PTFE) sheet by femtosecond laser. The femtosecond laser ablated surfaces show durable superhydrophobicity and ultralow water adhesion even after storing in a harsh environment for a long time, including strong acid, strong alkali, and high temperature. A penetrating microholes array was further generated on the rough superhydrophobic PTFE sheet by a subsequent mechanical drilling process. The as-prepared material was successfully applied in the field of oil/water separation due to the inverse superhydrophobicity and superoleophilicity.
Packing of poly(tetrafluoroethylene) in the liquid state: Molecular dynamics simulation and theory
NASA Astrophysics Data System (ADS)
Tsige, Mesfin; Curro, John G.; Grest, Gary S.
2008-12-01
Molecular dynamics simulations and polymer reference interaction site model theory calculations were carried out on the C48F98 oligomer of poly(tetrafluoroethylene) (PTFE) at 500 and 600 K. The exp-6 force field of Borodin, Smith, and Bedrov, was used in both the simulation and theory. The agreement between theory and simulation was equivalent to earlier studies on polyolefin melts. The intermolecular pair correlation functions of PTFE were shifted to larger distances relative to polyethylene (PE) due to the difference in the van der Waals radii of F and H atoms. A similar shift to lower wave vectors was found in the structure factor of PTFE relative to PE.
ERIC Educational Resources Information Center
Wise, Justin C.; Sevcik, Rose A.; Morris, Robin D.; Lovett, Maureen W.; Wolf, Maryanne; Kuhn, Melanie; Meisinger, Beth; Schwanenflugel, Paula
2010-01-01
Purpose: The purpose of this study was to examine whether different measures of oral reading fluency relate differentially to reading comprehension performance in two samples of second-grade students: (a) students who evidenced difficulties with nonsense-word oral reading fluency, real-word oral reading fluency, and oral reading fluency of…
Reading Fluency and Its Intervention.
ERIC Educational Resources Information Center
Wolf, Maryanne; Katzir-Cohen, Tami
2001-01-01
Confronts 3 large lacunae in research on reading fluency: definition, component structure, and theory-based intervention. Presents a developmental- and component-based definition of reading fluency. Discusses how different types of current fluency interventions correspond to particular components in fluency's structure and to particular phases of…
Spherical microglass particle impingement studies of thermoplastic materials at normal incidence
NASA Technical Reports Server (NTRS)
Veerabhadra Rao, P.; Buckley, D. H.
1984-01-01
Light optical and scanning electron microscope studies were conducted to characterize the erosion resistance of polymethyl methacrylate (PMMA), polycarbonate (PC), polytetrafluoroethylene (PTFE) and ultra-high-molecular-weight-polyethylene (UHMWPE). Erosion was caused by a jet of spherical micro-glass beads at normal impact. During the initial stages of damage, the surfaces of these materials were studied using a profilometer. Material buildup above the original surface was observed on PC and PMMA. As erosion progressed, this buildup disappeared as the pit became deeper. Little or no buildup was observed on PTFE and on UHMWPE. UHMWPE and PTFE are the most resistant materials and PMMA the least. Favorable properties for high erosion resistance seem to be high values of ultimate elongation, and strain energy and a low value of the modulus of elasticity. Erosion-rate-versus-time curves of PC and PTFE exhibit incubation, acceleration and steady state periods. A continuously increasing erosion rate period was observed however for PMMA instead of a steady state period. At early stages of damage and at low impact pressure material removal mechanisms appear to be similar to those for metallic materials.
Spherical micro-glass particle impingement studies of thermoplastic materials at normal incidence
NASA Technical Reports Server (NTRS)
Rao, P. V.; Buckley, D. H.
1983-01-01
Light optical and scanning electron microscope studies were conducted to characterize the erosion resistance of polymethyl methacrylate (PMMA), polycarbonate (PC), polytetrafluoroethylene (PTFE) and ultra-high-molecular-weight-polyethylene (UHMWPE). Erosion was caused by a jet of spherical micro-glass beads at normal impact. During the initial stages of damage, the surfaces of these materials were studied using a profilometer. Material buildup above the original surface was observed on PC and PMMA. As erosion progressed, this buildup disappeared as the pit became deeper. Little or no buildup was observed on PTFE and on UHMWPE. UHMWPE and PTFE are the most resistant materials and PMMA the least. Favorable properties for high erosion resistance seem to be high values of ultimate elongation, and strain energy and a low value of the modulus of elasticity. Erosion-rate-versus-time curves of PC and PTFE exhibit incubation, acceleration and steady state periods. A continuously increasing erosion rate period was observed however for PMMA instead of a steady state period. At early stages of damage and at low impact pressure material removal mechanisms appear to be similar to those for metallic materials.
Li, Yan; Wang, Zaicheng; Jiang, Chunlan; Niu, Haohao
2017-02-13
Metal/fluoropolymer composites are a category of energetic structural materials that release energy through exothermic chemical reactions initiated under highly dynamic loadings. In this paper, the chemical reaction mechanism of PTFE (polytetrafluoroethylene)/Ti/W composites is investigated through thermal analysis and composition analysis. These composites undergo exothermic reactions at 510 °C to 600 °C, mainly producing TiF x . The tungsten significantly reduces the reaction heat due to its inertness. In addition, the dynamic compression properties and impact-induced reaction behaviors of PTFE/Ti/W composites with different W content prepared by pressing and sintering are studied using Split Hopkinson Pressure Bar and high speed photography. The results show that both the mechanical strength and the reaction degree are significantly improved with the increasing strain rate. Moreover, as W content increases, the mechanical strength is enhanced, but the elasticity/plasticity is decreased. The PTFE/Ti/W composites tend to become more inert with the increasing W content, which is reflected by the reduced reaction degree and the increased reaction threshold for the impact ignition.
Yu, W H; Kang, E T; Neoh, K G
2005-01-04
Surface modification of poly(tetrafluoroethylene) (PTFE) films by well-defined comb copolymer brushes was carried out. Peroxide initiators were generated directly on the PTFE film surface via radio frequency Ar plasma pretreatment, followed by air exposure. Poly(glycidyl methacrylate) (PGMA) brushes were first prepared by surface-initiated reversible addition-fragmentation chain transfer polymerization from the peroxide initiators on the PTFE surface in the presence of a chain transfer agent. Kinetics study revealed a linear increase in the graft concentration of PGMA with the reaction time, indicating that the chain growth from the surface was consistent with a "controlled" or "living" process. alpha-Bromoester moieties were attached to the grafted PGMA by reaction of the epoxide groups with 2-bromo-2-methylpropionic acid. The comb copolymer brushes were subsequently prepared via surface-initiated atom transfer radical polymerization of two hydrophilic vinyl monomers, including poly(ethylene glycol) methyl ether methacrylate and sodium salt of 4-styrenesulfonic acid. The chemical composition of the modified PTFE surfaces was characterized by X-ray photoelectron spectroscopy.
Creation and Validation of Sintered PTFE BRDF Targets & Standards
Durell, Christopher; Scharpf, Dan; McKee, Greg; L’Heureux, Michelle; Georgiev, Georgi; Obein, Gael; Cooksey, Catherine
2016-01-01
Sintered polytetrafluoroethylene (PTFE) is an extremely stable, near-perfect Lambertian reflecting diffuser and calibration standard material that has been used by national labs, space, aerospace and commercial sectors for over two decades. New uncertainty targets of 2 % on-orbit absolute validation in the Earth Observing Systems community have challenged the industry to improve is characterization and knowledge of almost every aspect of radiometric performance (space and ground). Assuming “near perfect” reflectance for angular dependent measurements is no longer going to suffice for many program needs. The total hemispherical spectral reflectance provides a good mark of general performance; but, without the angular characterization of bidirectional reflectance distribution function (BRDF) measurements, critical data is missing from many applications and uncertainty budgets. Therefore, traceable BRDF measurement capability is needed to characterize sintered PTFE’s angular response and provide a full uncertainty profile to users. This paper presents preliminary comparison measurements of the BRDF of sintered PTFE from several laboratories to better quantify the BRDF of sintered PTFE, assess the BRDF measurement comparability between laboratories, and improve estimates of measurement uncertainties under laboratory conditions. PMID:26900206
Li, Yan; Wang, Zaicheng; Jiang, Chunlan; Niu, Haohao
2017-01-01
Metal/fluoropolymer composites are a category of energetic structural materials that release energy through exothermic chemical reactions initiated under highly dynamic loadings. In this paper, the chemical reaction mechanism of PTFE (polytetrafluoroethylene)/Ti/W composites is investigated through thermal analysis and composition analysis. These composites undergo exothermic reactions at 510 °C to 600 °C, mainly producing TiFx. The tungsten significantly reduces the reaction heat due to its inertness. In addition, the dynamic compression properties and impact-induced reaction behaviors of PTFE/Ti/W composites with different W content prepared by pressing and sintering are studied using Split Hopkinson Pressure Bar and high speed photography. The results show that both the mechanical strength and the reaction degree are significantly improved with the increasing strain rate. Moreover, as W content increases, the mechanical strength is enhanced, but the elasticity/plasticity is decreased. The PTFE/Ti/W composites tend to become more inert with the increasing W content, which is reflected by the reduced reaction degree and the increased reaction threshold for the impact ignition. PMID:28772534
Paramo, Erica; Palmero, Susana; Heras, Aranzazu; Colina, Alvaro
2018-02-01
A novel methodology to prepare sensors based on carbon nanostructures electrodes modified by metal nanoparticles is proposed. As a proof of concept, a novel bismuth nanoparticle/carbon nanofiber (Bi-NPs/CNF) electrode and a carbon nanotube (CNT)/gold nanoparticle (Au-NPs) have been developed. Bi-NPs/CNF films were prepared by 1) filtering a dispersion of CNFs on a polytetrafluorethylene (PTFE) filter, and 2) filtering a dispersion of Bi-NPs chemically synthesized through this CNF/PTFE film. Next the electrode is prepared by sticking the Bi-NPs/CNF/PTFE film on a PET substrate. In this work, Bi-NPs/CNF ratio was optimized using a Cd 2+ solution as a probe sample. The Cd anodic stripping peak intensity, registered by differential pulse anodic stripping voltammetry (DPASV), is selected as target signal. The voltammograms registered for Cd stripping with this Bi-NPs/CNF/PTFE electrode showed well-defined and highly reproducible electrochemical. The optimized Bi-NPs/CNF electrode exhibits a Cd 2+ detection limit of 53.57 ppb. To demonstrate the utility and versatility of this methodology, single walled carbon nanotubes (SWCNTs) and gold nanoparticles (Au-NPs) were selected to prepare a completely different electrode. Thus, the new Au-NPs/SWCNT/PTFE electrode was tested with a multiresponse technique. In this case, UV/Vis absorption spectroelectrochemistry experiments were carried out for studying dopamine, demonstrating the good performance of the Au-NPs/SWCNT electrode developed. Copyright © 2017 Elsevier B.V. All rights reserved.
Direct glycerol fuel cell with polytetrafluoroethylene (PTFE) thin film separator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Benipal, Neeva; Qi, Ji; Dalian Univ. of Technology, Dalian
Here, anion-exchange membrane-based direct glycerol fuel cells (AEM-DGFCs) can yield high power density, however challenges exist in developing chemically stable AEMs. Here, we demonstrate a porous PTFE thin film, a well-known chemical, electro-chemical, and thermal robust material that can serve as a separator between anode and cathode, thus achieving high DGFC’s performance. A simple aqueous-phase reduction method was used to prepare carbon nanotube supported PdAg nanoparticles (PdAg/CNT) with an average particle size of 2.9 nm. A DGFC using a PTFE thin film without any further modification with PdAg/CNT anode catalyst exhibits a peak power density of 214.7 mW cm –2more » at 80 °C, about 22.6% lower than a DGFC using a state-of-the-art AEM. We report a 5.8% decrease and 11.1% decrease in cell voltage for a PTFE thin film and AEM; similarly, the cell voltage degradation rate decreases from 1.2 to 0.8 mV h –1 for PTFE thin film, while for AEM, it decreases from 9.6 to 3.0 mV h –1 over an 80 h durability test period. Transmission electron microscopy results indicate that the average particle size of PdAg/CNT increases from 2.9 to 3.7 nm after 80 h discharge; this suggests that PdAg particle growth may be the main reason for the performance drop.« less
Binder materials for the cathodes applied to self-stratifying membraneless microbial fuel cell.
Walter, Xavier Alexis; Greenman, John; Ieropoulos, Ioannis
2018-04-19
The recently developed self-stratifying membraneless microbial fuel cell (SSM-MFC) has been shown as a promising concept for urine treatment. The first prototypes employed cathodes made of activated carbon (AC) and polytetrafluoroethylene (PTFE) mixture. Here, we explored the possibility to substitute PTFE with either polyvinyl-alcohol (PVA) or PlastiDip (CPD; i.e. synthetic rubber) as binder for AC-based cathode in SSM-MFC. Sintered activated carbon (SAC) was also tested due to its ease of manufacturing and the fact that no stainless steel collector is needed. Results indicate that the SSM-MFC having PTFE cathodes were the most powerful measuring 1617 μW (11 W·m -3 or 101 mW·m -2 ). SSM-MFC with PVA and CPD as binders were producing on average the same level of power (1226 ± 90 μW), which was 24% less than the SSM-MFC having PTFE-based cathodes. When balancing the power by the cost and environmental impact, results clearly show that PVA was the best alternative. Power wise, the SAC cathodes were shown being the less performing (≈1070 μW). Nonetheless, the lower power of SAC was balanced by its inexpensiveness. Overall results indicate that (i) PTFE is yet the best binder to employ, and (ii) SAC and PVA-based cathodes are promising alternatives that would benefit from further improvements. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.
Direct glycerol fuel cell with polytetrafluoroethylene (PTFE) thin film separator
Benipal, Neeva; Qi, Ji; Dalian Univ. of Technology, Dalian; ...
2017-01-04
Here, anion-exchange membrane-based direct glycerol fuel cells (AEM-DGFCs) can yield high power density, however challenges exist in developing chemically stable AEMs. Here, we demonstrate a porous PTFE thin film, a well-known chemical, electro-chemical, and thermal robust material that can serve as a separator between anode and cathode, thus achieving high DGFC’s performance. A simple aqueous-phase reduction method was used to prepare carbon nanotube supported PdAg nanoparticles (PdAg/CNT) with an average particle size of 2.9 nm. A DGFC using a PTFE thin film without any further modification with PdAg/CNT anode catalyst exhibits a peak power density of 214.7 mW cm –2more » at 80 °C, about 22.6% lower than a DGFC using a state-of-the-art AEM. We report a 5.8% decrease and 11.1% decrease in cell voltage for a PTFE thin film and AEM; similarly, the cell voltage degradation rate decreases from 1.2 to 0.8 mV h –1 for PTFE thin film, while for AEM, it decreases from 9.6 to 3.0 mV h –1 over an 80 h durability test period. Transmission electron microscopy results indicate that the average particle size of PdAg/CNT increases from 2.9 to 3.7 nm after 80 h discharge; this suggests that PdAg particle growth may be the main reason for the performance drop.« less
Fracture and damage evolution of fluorinated polymers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brown, E. N.; Rae, P.; Orler, E. B.
2004-01-01
Fluoropolymers are often semi-crystalline in nature, with their linear chains forming complicated phases near room temperature and ambient pressure. The most widely used fluorocarbon polymer for engineering applications is polytetrafluoroethylene (PTFE), due to its extremely low coefficient of friction, outstanding resistance to corrosion, and excellent electrical properties. The phase structure of PTFE is complex with four well-characterized crystalline phases (three observed at atmospheric pressure) and substantial molecular motion well below the melting point. The first-order transition at 19 C between phases II and IV is an unraveling in the helical conformation. Further rotational disordering and untwisting of the helices occursmore » above 30 C giving way to phase I. The mechanical behavior, including fracture and damage evolution, of PTFE depends on the chain and segment motions dictated by crystalline phase microstructure. The presence of three unique phases at ambient pressure near room temperature implies that failure during standard operating conditions may be strongly dependent on the phase. This paper presents a preliminary study of fracture and damage evolution in PTFE with the effects of temperature-induced phase on fracture mechanisms. The quasi-static fracture of PTFE in the atmospheric pressure regime, over a range of temperatures, was found to be strongly phase dependent: phase II exhibits brittle-fracture, phase IV displays ductile-fracture with crazing and some stable crack growth, and plastic flow dominates phase 1. The bulk failure properties are correlated to failure mechanisms through fractography of the fracture surfaces (optical microscopy and scanning electron microscopy (SEM)).« less
Fluoropolymer Films Deposited by Argon Ion-Beam Sputtering of Polytetrafluoroethylene
NASA Technical Reports Server (NTRS)
Golub, Morton A.; Banks, Bruce A.; Kliss, Mark (Technical Monitor)
1998-01-01
The FT-IR, XPS and UV spectra of fluoropolymer films (SPTFE-I) deposited by argon ion-beam sputtering of polytetrafluoroethylene (PTFE) were obtained and compared with prior corresponding spectra of fluoropolymer films (SPTFE-P) deposited by argon rf plasma sputtering of PTFE. Although the F/C ratios for SPTFE-I and -P (1.63 and 1.51) were similar, their structures were quite different in that there was a much higher concentration of CF2 groups in SPTFE-I than in SPTFE-P, ca. 61 and 33% of the total carbon contents, respectively. The FT-IR spectra reflect that difference, that for SPTFE-I showing a distinct doublet at 1210 and 1150 per centimeter while that for SPTFE-P presents a broad, featureless band at ca. 1250 per centimeter. The absorbance of the 1210-per centimeter band in SPTFE-I was proportional to the thickness of the film, in the range of 50-400 nanometers. The SPTFE-I was more transparent in the UV than SPTFE-P at comparable thickness. The mechanism for SPTFE-I formation likely involves "chopping off" of oligomeric segments of PTFE as an accompaniment to "plasma" polymerization of TFE monomer or other fluorocarbon fragments generated in situ from PTFE on impact with energetic Ar ions. Data are presented for SPTFE-I deposits and the associated Ar(+) bombarded PTFE targets where a fresh target was used for each run or a single target was used for a sequence of runs.
NASA Astrophysics Data System (ADS)
Chaurasia, S.; Rastogi, V.; Rao, U.; Sijoy, C. D.; Mishra, V.; Deo, M. N.
2017-11-01
The transient state of excitation and relaxation processes in materials under shock compression can be investigated by coupling the laser driven shock facility with Raman spectroscopy. For this purpose, a time resolved Raman spectroscopy setup has been developed to monitor the physical and the chemical changes such as phase transitions, chemical reactions, molecular kinetics etc., under shock compression with nanosecond time resolution. This system consist of mainly three parts, a 2 J/8 ns Nd:YAG laser system used for generation of pump and probe beams, a Raman spectrometer with temporal and spectral resolution of 1.2 ns and 3 cm-1 respectively and a target holder in confinement geometry assembly. Detailed simulation for the optimization of confinement geometry targets is performed. Time resolved measurement of polytetrafluoroethylene (PTFE) targets at focused laser intensity of 2.2 GW/cm2 has been done. The corresponding pressure in the Aluminum and PTFE are 3.6 and 1.7 GPa respectively. At 1.7 GPa in PTFE, a red shift of 5 cm-1 is observed for the CF2 twisting mode (291 cm-1). Shock velocity in PTFE is calculated by measuring rate of change of ratios of the intensity of Raman lines scattered from shocked volume to total volume of sample in the laser focal spot along the laser axis. The calculated shock velocity in PTFE is found to be 1.64 ± 0.16 km/s at shock pressure of 1.7 GPa, for present experimental conditions.
Factors Contributing to Pilot Valve Fuel Seal Extrusion in Orbiter PRCS Thrusters
NASA Technical Reports Server (NTRS)
Waller, J.M.; Saulsberry, R.L.; Albright, John D.
2000-01-01
Extrusion of the polytetrafluoroethylene (PTFE) pilot seal used in the monomethylhydrazine (fuel) valve of the Orbiter Primary Reaction Control System (PRCS) thrusters has been implicated in numerous on-orbit thruster failures and on-ground valve failures. Two extrusion mechanisms have been proposed, one or both may be occurring. The first mechanism is attributed to thermal expansion mismatch between adjacent PTFE and metal parts used in the fuel valve, and is referred to as thermal extrusion. The second mechanism is attributed to nitrogen tetroxide (oxidizer) leakage from the adjacent oxidizer valve on the same thruster during ground turnaround, and is referred to as oxidizer-induced extrusion. Model calculations of PTFE pilot seal in an exact pilot valve configuration show that extrusion can be caused by differential thermal expansion, without the intervening influence of oxidizer. Experimental data on semitrapped PTFE and TFM (modified PTFE) specimens simulating a fuel pilot valve configuration show that thermal extrusion 1) is incremental and irreversible, 2) increases with the size of the thermal excursion, 3) decreases with successive thermal cycling, and 4) is accompanied by gap formation. Both PTFE and TFM exhibit a higher affinity for oxidizer than fuel. The property changes associated with oxidizer uptake may explain why oxidizer seals do not exhibit extrusion. Impression replicas of fuel pilot seals removed from the Orbiter fleet show two types of extrusion: extrusion of the entire seal (loaded extrusion), or extrusion of non-sealing surface (unloaded extrusion). Both extrusion types may arise from differences in service history, rather than in failure mechanism. The plausibility oxidizer-induced extrusion was evaluated. Preliminary calculations suggest that enough energy, heat, or gas may be liberated under certain operational scenarios to cause catastrophic extrusion. However, given the lack of supporting data, conclusions implicating oxidizer leakage as a factor in extrusion must be made with caution.
Impaired Verb Fluency: A Sign of Mild Cognitive Impairment
ERIC Educational Resources Information Center
Ostberg, Per; Fernaeus, Sven-Erik; Hellstrom, Ake; Bogdanovic, Nenad; Wahlund, Lars Olof
2005-01-01
We assessed verb fluency vs. noun and letter-based fluency in 199 subjects referred for cognitive complaints including Subjective Cognitive Impairment, Mild Cognitive Impairment, and Alzheimer's disease. ANCOVAs and factor analyses identified verb, noun, and letter-based fluency as distinct tasks. Verb fluency performance in Mild Cognitive…
Word Reading Fluency as a Serial Naming Task
ERIC Educational Resources Information Center
Protopapas, Athanassios; Katopodi, Katerina; Altani, Angeliki; Georgiou, George K.
2018-01-01
Word list reading fluency is theoretically expected to depend on single word reading speed. Yet the correlation between the two diminishes with increasing fluency, while fluency remains strongly correlated to serial digit naming. We hypothesized that multi-element sequence processing is an important component of fluency. We used confirmatory…
Silent Reading Fluency and Comprehension in Bilingual Children
O'Brien, Beth A.; Wallot, Sebastian
2016-01-01
This paper focuses on reading fluency by bilingual primary school students, and the relation of text fluency to their reading comprehension. Group differences were examined in a cross-sectional design across the age range when fluency is posed to shift from word-level to text-level. One hundred five bilingual children from primary grades 3, 4, and 5 were assessed for English word reading and decoding fluency, phonological awareness, rapid symbol naming, and oral language proficiency with standardized measures. These skills were correlated with their silent reading fluency on a self-paced story reading task. Text fluency was quantified using non-linear analytic methods: recurrence quantification and fractal analyses. Findings indicate that more fluent text reading appeared by grade 4, similar to monolingual findings, and that different aspects of fluency characterized passage reading performance at different grade levels. Text fluency and oral language proficiency emerged as significant predictors of reading comprehension. PMID:27630590
Mere exposure effect: A consequence of direct and indirect fluency-preference links.
Willems, Sylvie; Van der Linden, Martial
2006-06-01
In three experiments, picture quality between test items was manipulated to examine whether subjects' expectations about the fluency normally associated with these different stimuli might influence the effects of fluency on preference or familiarity-based recognition responses. The results showed that fluency due to pre-exposure influenced responses less when objects were presented with high picture quality, suggesting that attributions of fluency to preference and familiarity are adjusted according to expectations about the different test pictures. However, this expectations influence depended on subjects' awareness of these different quality levels. Indeed, imperceptible differences seemed not to induce expectations about the test item fluency. In this context, fluency due to both picture quality and pre-exposure influenced direct responses. Conversely, obvious, and noticed, differences in test picture quality did no affect responses, suggesting that expectations moderated attributions of fluency only when fluency normally associated with these different stimuli was perceptible but difficult to assess.
Verbal Fluency Performance in Patients with Non-demented Parkinson's Disease
Khatoonabadi, Ahmad Reza; Bakhtiyari, Jalal
2013-01-01
Objective While Parkinson's disease (PD) has traditionally been defined by motor symptoms, many researches have indicated that mild cognitive impairment is common in non-demented PD patients. The purpose of this study was to compare verbal fluency performance in non-demented Parkinson's disease patients with healthy controls. Method In this cross-sectional study thirty non-demented Parkinson's disease patients and 30 healthy controls, matched by age, gender and education, were compared on verbal fluency performance. Verbal fluency was studied with a Phonemic Fluency task using the letters F, A, and S, a semantic fluency task using the categories animals and fruits. The independent t-test was used for data analysis. Results Overall, participants generated more words in the semantic fluency task than in the phonemic fluency task. Results revealed significant differences between patients and controls in semantic fluency task (p<.05). In addition, PD patients showed a significant reduction of correctly generated words in letter fluency task. The total number of words produced was also significantly lower in the PD group (p<.05). Conclusion Verbal fluency disruption is implied in non-demented PD patients in association with incipient cognitive impairment. PMID:23682253
36 CFR 230.20 - Scope and authority.
Code of Federal Regulations, 2010 CFR
2010-07-01
... other members of the public to: maintain, expand, and preserve forest and tree cover; expand research and education efforts related to trees and forest cover; enhance technical skills and understanding of tree maintenance and practices involving cultivation of trees, shrubs and complementary ground covers...
36 CFR 230.20 - Scope and authority.
Code of Federal Regulations, 2014 CFR
2014-07-01
... other members of the public to: maintain, expand, and preserve forest and tree cover; expand research and education efforts related to trees and forest cover; enhance technical skills and understanding of tree maintenance and practices involving cultivation of trees, shrubs and complementary ground covers...
36 CFR 230.20 - Scope and authority.
Code of Federal Regulations, 2013 CFR
2013-07-01
... other members of the public to: maintain, expand, and preserve forest and tree cover; expand research and education efforts related to trees and forest cover; enhance technical skills and understanding of tree maintenance and practices involving cultivation of trees, shrubs and complementary ground covers...
Smith-Spark, James H; Henry, Lucy A; Messer, David J; Zięcik, Adam P
2017-08-01
The executive function of fluency describes the ability to generate items according to specific rules. Production of words beginning with a certain letter (phonemic fluency) is impaired in dyslexia, while generation of words belonging to a certain semantic category (semantic fluency) is typically unimpaired. However, in dyslexia, verbal fluency has generally been studied only in terms of overall words produced. Furthermore, performance of adults with dyslexia on non-verbal design fluency tasks has not been explored but would indicate whether deficits could be explained by executive control, rather than phonological processing, difficulties. Phonemic, semantic and design fluency tasks were presented to adults with dyslexia and without dyslexia, using fine-grained performance measures and controlling for IQ. Hierarchical regressions indicated that dyslexia predicted lower phonemic fluency, but not semantic or design fluency. At the fine-grained level, dyslexia predicted a smaller number of switches between subcategories on phonemic fluency, while dyslexia did not predict the size of phonemically related clusters of items. Overall, the results suggested that phonological processing problems were at the root of dyslexia-related fluency deficits; however, executive control difficulties could not be completely ruled out as an alternative explanation. Developments in research methodology, equating executive demands across fluency tasks, may resolve this issue. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
ERIC Educational Resources Information Center
Lanska, Meredith; Olds, Justin M.; Westerman, Deanne L.
2014-01-01
On a recognition memory test, both perceptual and conceptual fluency can engender a sense of familiarity and elicit recognition memory illusions. To date, perceptual and conceptual fluency have been studied separately but are they interchangeable in terms of their influence on recognition judgments? Five experiments compared the effect of…
Story Retell: A Fluency-Based Indicator of Reading Comprehension
ERIC Educational Resources Information Center
Roberts, Greg; Good, Roland; Corcoran, Stephanie
2005-01-01
This article presents a fluency-based measure of reading comprehension. A part of the Vitals Indicators of Progress (VIP) system, the measure outlined here represents an alternate form to the retell-fluency measure in the Dynamic Indicators of Basic Early Literacy System (DIBELS). Measures of retell fluency provide an efficient, fluency-based tool…
Forster, Michael; Leder, Helmut; Ansorge, Ulrich
2013-04-01
According to the processing-fluency explanation of aesthetics, more fluently processed stimuli are preferred (R. Reber, N. Schwarz, & P. Winkielman, 2004, Processing fluency and aesthetic pleasure: Is beauty in the perceiver's processing experience? Personality and Social Psychology Review, Vol. 8, pp. 364-382.). In this view, the subjective feeling of ease of processing is considered important, but this has not been directly tested in perceptual processing. In two experiments, we therefore objectively manipulated fluency (ease of processing) with subliminal perceptual priming (Study 1) and variations in presentation durations (Study 2). We assessed the impact of objective fluency on feelings of fluency and liking, as well as their interdependence. In line with the processing-fluency account, we found that objectively more fluent images were indeed judged as more fluent and were also liked more. Moreover, differences in liking were even stronger when data were analyzed according to felt fluency. These findings demonstrate that perceptual fluency is not only explicitly felt, it can also be reported and is an important determinant of liking. PsycINFO Database Record (c) 2013 APA, all rights reserved.
Peter, Jessica; Kaiser, Jannis; Landerer, Verena; Köstering, Lena; Kaller, Christoph P; Heimbach, Bernhard; Hüll, Michael; Bormann, Tobias; Klöppel, Stefan
2016-12-01
The exploration and retrieval of words during category fluency involves different strategies to improve or maintain performance. Deficits in that task, which are common in patients with amnestic mild cognitive impairment (aMCI), mirror either impaired semantic memory or dysfunctional executive control mechanisms. Relating category fluency to tasks that place greater demands on either semantic knowledge or executive functions might help to determine the underlying cognitive process. The aims of this study were to compare performance and strategy use of 20 patients with aMCI to 30 healthy elderly controls (HC) and to identify the dominant component (either executive or semantic) for better task performance in category fluency. Thus, the relationship between category fluency, design fluency and naming was examined. As fluency tasks have been associated with the superior frontal gyrus (SFG), the inferior frontal gyrus (IFG), and the temporal pole, we further explored the relationship between gray matter volume in these areas and both performance and strategy use. Patients with aMCI showed significantly lower performance and significantly less strategy use during fluency tasks compared to HC. However, both groups equally improved their performance when repeatedly confronted with the same task. In aMCI, performance during category fluency was significantly predicted by design fluency performance, while in HC, it was significantly predicted by naming performance. In HC, volume of the SFG significantly predicted both category and design fluency performance, and strategy use during design fluency. In aMCI, the SFG and the IFG predicted performance during both category and design fluency. The IFG significantly predicted strategy use during category fluency in both groups. The reduced category fluency performance in aMCI seems to be primarily due to dysfunctional executive control mechanisms rather than impaired semantic knowledge. This finding is directly relevant to patients in the different stages of Alzheimer's disease as it links the known semantic fluency deficit in this population to executive functions. Although patients with aMCI are impaired in both performance and strategy use compared to HC, they are able to increase performance over time. However, only HC were able to significantly improve the utilization of fluency strategies in both category and design fluency over time. HC seem to rely more heavily on the SFG during fluency tasks, while in patients with aMCI additional frontal brain areas are involved, possibly reflecting compensational processes. Copyright © 2016 Elsevier Ltd. All rights reserved.
What Do We Mean by Writing Fluency and How Can It Be Validly Measured?
ERIC Educational Resources Information Center
Abdel Latif, Muhammad M. Mahmoud
2013-01-01
Fluency is an essential component in writing ability and development. Writing fluency research is important to researchers and teachers interested in facilitating students' written text production and in assessing writing. This calls for reaching a better understanding of writing fluency and how it should be measured. Although fluency is the…
Kim, Young-Suk Grace; Wagner, Richard K.
2015-01-01
In the present study we investigated a developmentally changing role of text reading fluency in mediating the relations of word reading fluency and listening comprehension to reading comprehension. We addressed this question by using longitudinal data from Grades 1 to 4, and employing structural equation models. Results showed that the role of text reading fluency changes over time as children’s reading proficiency develops. In the beginning phase of reading development (Grade 1), text reading fluency was not independently related to reading comprehension over and above word reading fluency and listening comprehension. In Grades 2 to 4, however, text reading fluency completely mediated the relation between word reading fluency and reading comprehension whereas it partially mediated the relation between listening comprehension and reading comprehension. These results suggest that text reading fluency is a dissociable construct that plays a developmentally changing role in reading acquisition. PMID:25848201
Impact Initiation of Rods of Pressed Polytetrafluoroethylene (PTFE) and Aluminum Powders
NASA Astrophysics Data System (ADS)
Mock, Willis, Jr.
2005-07-01
A gas gun has been used to investigate the shock initiation of rods consisting of a mixture of 74 wt % PTFE (28 μm particle size) and 26 wt % aluminum (5 μm particle size) powders. The 7.6 mm diameter by 51 mm long rods were fabricated from material that had been pressed and sintered to a full density of 2.27 gm/cm^ 3. The rods were sabot-launched into 4340 steel anvils at impact velocities ranging from 104 to 777 m/s. This corresponds to calculated impact stresses of 3.3 to 48 kbar. The experiments were carried out in a 50-100 mtorr vacuum. A framing camera was used to observe the time sequence of events. These include changes in rod shape, fracture, and the initiation and evolution of the reaction phenomena. Observation of first visible light after impact was taken as the initiation time. Initiation of the reaction occurred at discrete locations in the rod material. At low velocity, no initiation occurred. Above an initiation threshold, the initiation time dropped abruptly from 56 μs just above threshold to 4 μs at the highest impact velocity. Two experiments were performed for pure PTFE material for comparison with the PTFE/Al rods. The pure PTFE showed more extensive radial flow without obvious brittle fracture. For the 784 m/s impact experiment, small points of light were observed on the edge of the mushroomed portion of the rod about 20 μs after impact, suggesting the onset of chemical reaction.
Adhesive interactions of geckos with wet and dry fluoropolymer substrates
Stark, Alyssa Y.; Dryden, Daniel M.; Olderman, Jeffrey; Peterson, Kelly A.; Niewiarowski, Peter H.; French, Roger H.; Dhinojwala, Ali
2015-01-01
Fluorinated substrates like Teflon® (poly(tetrafluoroethylene); PTFE) are well known for their role in creating non-stick surfaces. We showed previously that even geckos, which can stick to most surfaces under a wide variety of conditions, slip on PTFE. Surprisingly, however, geckos can stick reasonably well to PTFE if it is wet. In an effort to explain this effect, we have turned our attention to the role of substrate surface energy and roughness when shear adhesion occurs in media other than air. In this study, we removed the roughness component inherent to commercially available PTFE and tested geckos on relatively smooth wet and dry fluoropolymer substrates. We found that roughness had very little effect on shear adhesion in air or in water and that the level of fluorination was most important for shear adhesion, particularly in air. Surface energy calculations of the two fluorinated substrates and one control substrate using the Tabor–Winterton approximation and the Young–Dupré equation were used to determine the interfacial energy of the substrates. Using these interfacial energies we estimated the ratio of wet and dry normal adhesion for geckos clinging to the three substrates. Consistent with the results for rough PTFE, our predictions show a qualitative trend in shear adhesion based on fluorination, and the quantitative experimental differences highlight the unusually low shear adhesion of geckos on dry smooth fluorinated substrates, which is not captured by surface energy calculations. Our work has implications for bioinspired design of synthetics that can preferentially stick in water but not in air. PMID:26109635
In Vitro Tensile Strength Study on Suturing Technique and Material.
González-Barnadas, Albert; Camps-Font, Octavi; Espanya-Grifoll, Dunia; España-Tost, Antoni; Figueiredo, Rui; Valmaseda-Castellón, Eduard
2017-06-01
Suture technique and materials are important in preventing complications such as wound dehiscences. The purpose of this study was to determine the tensile strength of different suturing techniques, comparing several materials with different diameters. One hundred sixty sutures were performed using silk, e-PTFE, and 2 types of polyamide (monofilament and Supramid). Ten simple, 10 horizontal mattress, and 10 combinations of the two stitches were performed with 4-0 gauge of each material. Additionally, 10 simple sutures were performed with the 5-0 gauge of each material. The maximum tensile force resisted by each suture was recorded. When 5 mm of traction was applied, the polyamide monofilament resisted significantly better without untying or breaking compared with Supramid or silk, while the e-PTFE was superior to all the others. However, the force when e-PTFE 4-0 sutures untied or broke was lower than for either type of polyamide. The combined technique withstood a significantly higher tensile force before unknotting or breaking than did the simple and mattress stitches. The 5-0 gauges of silk and both types of polyamide showed lower tensile strengths than the 4-0 materials. Among the 5-0 sutures, Supramid showed a higher tensile strength than silk. The combined suture technique possessed greater tensile strength than did a simple or a horizontal mattress suture, and e-PTFE 4-0 withstood more traction without untying or breaking than did all the other materials, although at a lower tensile force. With the exception of e-PTFE, 4-0 sutures had greater tensile strength than did 5-0 sutures.
Reber, Rolf; Wurtz, Pascal; Zimmermann, Thomas D
2004-03-01
Perceptual fluency is the subjective experience of ease with which an incoming stimulus is processed. Although perceptual fluency is assessed by speed of processing, it remains unclear how objective speed is related to subjective experiences of fluency. We present evidence that speed at different stages of the perceptual process contributes to perceptual fluency. In an experiment, figure-ground contrast influenced detection of briefly presented words, but not their identification at longer exposure durations. Conversely, font in which the word was written influenced identification, but not detection. Both contrast and font influenced subjective fluency. These findings suggest that speed of processing at different stages condensed into a unified subjective experience of perceptual fluency.
ERIC Educational Resources Information Center
De Jong, Nivja H.; Steinel, Margarita P.; Florijn, Arjen F.; Schoonen, Rob; Hulstijn, Jan H.
2012-01-01
This study investigated how task complexity affected native and non-native speakers' speaking performance in terms of a measure of communicative success (functional adequacy), three types of fluency (breakdown fluency, speed fluency, and repair fluency), and lexical diversity. Participants (208 non-native and 59 native speakers of Dutch) carried…
Reading Fluency beyond English: Investigations into Reading Fluency in Turkish Elementary Students
ERIC Educational Resources Information Center
Yildirim, Kasim; Rasinski, Timothy
2014-01-01
Reading fluency is one of the underlying factors of successful language curricula and it is also one of the defining characteristics of good readers. A lack of fluency is a common characteristic of struggling readers. There is a growing body of research that demonstrates proficiency in reading fluency is important for success in learning to read…
How Do Utterance Measures Predict Raters' Perceptions of Fluency in French as a Second Language?
ERIC Educational Resources Information Center
Préfontaine, Yvonne; Kormos, Judit; Johnson, Daniel Ezra
2016-01-01
While the research literature on second language (L2) fluency is replete with descriptions of fluency and its influence with regard to English as an additional language, little is known about what fluency features influence judgments of fluency in L2 French. This study reports the results of an investigation that analyzed the relationship between…
Cui, Jiaxin; Georgiou, George K; Zhang, Yiyun; Li, Yixun; Shu, Hua; Zhou, Xinlin
2017-02-01
Rapid automatized naming (RAN) has been found to predict mathematics. However, the nature of their relationship remains unclear. Thus, the purpose of this study was twofold: (a) to examine how RAN (numeric and non-numeric) predicts a subdomain of mathematics (arithmetic fluency) and (b) to examine what processing skills may account for the RAN-arithmetic fluency relationship. A total of 160 third-year kindergarten Chinese children (83 boys and 77 girls, mean age=5.11years) were assessed on RAN (colors, objects, digits, and dice), nonverbal IQ, visual-verbal paired associate learning, phonological awareness, short-term memory, speed of processing, approximate number system acuity, and arithmetic fluency (addition and subtraction). The results indicated first that RAN was a significant correlate of arithmetic fluency and the correlations did not vary as a function of type of RAN or arithmetic fluency tasks. In addition, RAN continued to predict addition and subtraction fluency even after controlling for all other processing skills. Taken together, these findings challenge the existing theoretical accounts of the RAN-arithmetic fluency relationship and suggest that, similar to reading fluency, multiple processes underlie the RAN-arithmetic fluency relationship. Copyright © 2016 Elsevier Inc. All rights reserved.
Recovery of ammonia from poultry litter using flat gas permeable membranes.
Rothrock, M J; Szögi, A A; Vanotti, M B
2013-06-01
The use of flat gas-permeable membranes was investigated as components of a new process to capture and recover ammonia (NH3) in poultry houses. This process includes the passage of gaseous NH3 through a microporous hydrophobic membrane, capture with a circulating dilute acid on the other side of the membrane, and production of a concentrated ammonium (NH4) salt. Bench- and pilot-scale prototype systems using flat expanded polytetrafluoroethylene (ePTFE) membranes and a sulfuric acid solution consistently reduced headspace NH3 concentrations from 70% to 97% and recovered 88% to 100% of the NH3 volatilized from poultry litter. The potential benefits of this technology include cleaner air inside poultry houses, reduced ventilation costs, and a concentrated liquid ammonium salt that can be used as a plant nutrient solution. Published by Elsevier Ltd.
Combustion of PTFE: The Effects of Gravity and Pigmentation on Ultrafine Particle Generation
NASA Technical Reports Server (NTRS)
McKinnon, J. Thomas; Srivastava, Rajiv; Todd, Paul
1997-01-01
Ultrafine particles generated during polymer thermodegradation are a major health hazard, owing to their unique pathway of processing in the lung. This hazard in manned spacecraft is poorly understood, because the particulate products of polymer thermodegradation are generated under low gravity conditions. Particulate generated from the degradation of PolyTetraFluoroEthylene (PTFE), insulation coating for 20 AWG copper wire (representative of spacecraft application) under intense ohmic heating were studied in terrestrial gravity and microgravity. Microgravity tests were done in a 1.2-second drop tower at the Colorado School of Mines (CSM). Thermophoretic sampling was used for particulate collection. Transmission Electron Microscopy (TEM) and Scanning Transmission Electron Microscopy (STEM) were used to examine the smoke particulates. Image software was used to calculate particle size distribution. In addition to gravity, the color of PTFE insulation has an overwhelming effect on size, shape and morphology of the particulate. Nanometer-sized primary particles were found in all cases, and aggregation and size distribution was dependent on both color and gravity; higher aggregation occurred in low gravity. Particulates from white, black, red and yellow colored PTFE insulations were studied. Elemental analysis of the particulates shows the presence of inorganic pigments.
NASA Astrophysics Data System (ADS)
Cho, Min Kyung; Park, Hee-Young; Lee, Hye Jin; Kim, Hyoung-Juhn; Lim, Ahyoun; Henkensmeier, Dirk; Yoo, Sung Jong; Kim, Jin Young; Lee, So Young; Park, Hyun S.; Jang, Jong Hyun
2018-04-01
Herein, we investigate the effects of catholyte feed method and anode binder content on the characteristics of anion exchange membrane water electrolysis (AEMWE) to construct a high-performance electrolyzer, revealing that the initial AEMWE performance is significantly improved by pre-feeding 0.5 M aqueous KOH to the cathode. The highest long-term activity during repeated voltage cycling is observed for AEMWE operation in the dry cathode mode, for which the best long-term performance among membrane electrode assemblies (MEAs) featuring polytetrafluoroethylene (PTFE) binder-impregnated (5-20 wt%) anodes is detected for a PTFE content of 20 wt%. MEAs with low PTFE content (5 and 9 wt%) demonstrate high initial performance, rapid performance decay, and significant catalyst loss from the electrode during long-term operation, whereas the MEA with 20 wt% PTFE allows stable water electrolysis for over 1600 voltage cycles. Optimization of cell operating conditions (i.e., operation in dry cathode mode at an optimum anode binder content following an initial solution feed) achieves an enhanced water splitting current density (1.07 A cm-2 at 1.8 V) and stable long-term AEMWE performance (0.01% current density reduction per voltage cycle).
Adherence of volatile propofol to various types of plastic tubing.
Maurer, F; Lorenz, D J; Pielsticker, G; Volk, T; Sessler, D I; Baumbach, J I; Kreuer, S
2017-01-23
Propofol is an intravenous anesthetic. Currently, it is not possible to routinely measure blood concentration of the drug in real time. However, multi-capillary column ion-mobility spectrometry of exhaled gas can estimate blood propofol concentration. Unfortunately, adhesion of volatile propofol on plastic materials complicates measurements. Therefore, it is necessary to consider the extent to which volatile propofol adheres to various plastics used in sampling tubing. Perfluoralkoxy (PFA), polytetrafluorethylene (PTFE), polyurethane (PUR), silicone, and Tygon tubing were investigated in an experimental setting using a calibration gas generator (HovaCAL). Propofol gas was measured for one hour at 26 °C, 50 °C, and 90 °C tubing temperature. Test tubing segments were then flushed with N 2 to quantify desorption. PUR and Tygon sample tubing absorbed all volatile propofol. The silicone tubing reached the maximum propofol concentration after 119 min which was 29 min after propofol gas exposure stopped. The use of PFA or PTFE tubing produced comparable and reasonably accurate propofol measurements. The desaturation time for the PFA was 10 min shorter at 26 °C than for PTFE. PFA tubing thus seems most suitable for measurement of volatile propofol, with PTFE as an alternative.
Light scattering of semitransparent sintered polytetrafluoroethylene films.
Li, Qinghe; Lee, Bong Jae; Zhang, Zhuomin M; Allen, David W
2008-01-01
Polytetrafluoroethylene (PTFE) is a strongly scattering material and has been regarded to have optical properties similar to biological tissues. In the present study, the bidirectional reflectance distribution function (BRDF) and the bidirectional transmittance distribution function (BTDF) of several PTFE films, with thicknesses from 0.11 to 10 mm, are measured using a laser scatterometer at the wavelength of 635 nm. The directional-hemispherical reflectance (R) and transmittance (T) were obtained by integrating BRDF and BTDF for normal incidence. Comparison of the ratio of the measured R and T with that calculated from the adding-doubling method allows the determination of the reduced scattering coefficient. Furthermore, the effect of surface scattering is investigated by measuring the polarization-dependent BRDF and BTDF at oblique incidence. By analyzing the measurement uncertainty of BTDF in the near-normal observation angles at normal incidence, the present authors found that the scattering coefficient of PTFE should exceed 1200 cm(-1), which is much greater than that of biological tissues. On the other hand, the absorption coefficient of PTFE must be less than 0.01 cm(-1), much smaller than that of biological tissues, a necessary condition to achieve R > or =0.98 with a 10-mm-thick slab.
Computer Simulations of Polytetrafluoroethylene in the Solid State
NASA Astrophysics Data System (ADS)
Holt, D. B.; Farmer, B. L.; Eby, R. K.; Macturk, K. S.
1996-03-01
Force field parameters (Set I) for fluoropolymers were previously derived from MOPAC AM1 semiempirical data on model molecules. A second set (Set II) was derived from the AM1 results augmented by ab initio calculations. Both sets yield reasonable helical and phase II packing structures for polytetrafluoroethylene (PTFE) chains. However, Set I and Set II differ in the strength of van der Waals interactions, with Set II having deeper potential wells (order of magnitude). To differentiate which parameter set provides a better description of PTFE behavior, molecular dynamics simulations have been performed with Biosym Discover on clusters of PTFE chains which begin in a phase II packing environment. Added to the model are artificial constraints which allow the simulation of thermal expansion without having to define periodic boundary conditions for each specific temperature of interest. The preliminary dynamics simulations indicate that the intra- and intermolecular interactions provided by Set I are too weak. The degree of helical disorder and chain motion are high even at temperatures well below the phase II-phase IV transition temperature (19 C). Set II appears to yield a better description of PTFE in the solid state.
EFFECTS OF TRITIUM EXPOSURE ON UHMW-PE, PTFE, AND VESPEL
DOE Office of Scientific and Technical Information (OSTI.GOV)
Clark, E; Kirk Shanahan, K
2006-05-31
Samples of three polymers, Ultra-High Molecular Weight Polyethylene (UHMW-PE), polytetrafluoroethylene (PTFE, also known as Teflon{reg_sign}), and Vespel{reg_sign} polyimide were exposed to 1 atmosphere of tritium gas at ambient temperature for varying times up to 2.3 years in closed containers. Sample mass and size measurements (to calculate density), spectra-colorimetry, dynamic mechanical analysis (DMA), and Fourier-transform infrared spectroscopy (FT-IR) were employed to characterize the effects of tritium exposure on these samples. Changes of the tritium exposure gas itself were characterized at the end of exposure by measuring total pressure and by mass spectroscopic analysis of the gas composition. None of the polymersmore » exhibited significant changes of density. The color of initially white UHMW-PE and PTFE dramatically darkened to the eye and the color also significantly changed as measured by colorimetry. The bulk of UHMW-PE darkened just like the external surfaces, however the fracture surface of PTFE appeared white compared to the PTFE external surfaces. The white interior could have been formed while the sample was breaking or could reflect the extra tritium dose at the surface directly from the gas. The dynamic mechanical response of UHMW-PE was typical of radiation effects on polymers- an initial stiffening (increased storage modulus) and reduction of viscous behavior after three months exposure, followed by lowering of the storage modulus after one year exposure and longer. The storage modulus of PTFE increased through about nine months tritium exposure, then the samples became too weak to handle or test using DMA. Characterization of Vespel{reg_sign} using DMA was problematic--sample-to-sample variations were significant and no systematic change with tritium exposure could be discerned. Isotopic exchange and incorporation of tritium into UHMW-PE (exchanging for protium) and into PTFE (exchanging for fluorine) was observed by FT-IR using an attenuated total reflectance method. No significant change in the Vespel{reg_sign} infrared spectrum was observed after three months exposure. Protium significantly pressurized the UHMW-PE containers during exposure to about nine atmospheres (the initial pressure was one atmosphere of tritium). This is consistent with the well-known production of hydrogen by irradiation of polyethylene by ionizing radiation. The total pressure in the PTFE containers decreased, and a mass balance reveals that the observed decrease is consistent with the formation of small amounts of {sup 3}HF, which is condensed at ambient temperature. No significant change of pressure occurred in the Vespel{reg_sign} containers; however the composition of the gas became about 50% protium, showing that Vespel{reg_sign} interacted with the tritium gas atmosphere to some degree. The relative resistance to degradation from tritium exposure is least for PTFE, more for UHMW-PE, and the most for Vespel{reg_sign}, which is consistent with the known relative resistance of these polymers to gamma irradiation. This qualitatively agrees with the concept of equivalent effects for equivalent absorbed doses of radiation damage of polymers. Some of the changes of different polymers are qualitatively similar; however each polymer exhibited unique property changes when exposed to tritium. Information from this study that can be applied to a tritium facility is: (1) the relative resistance to tritium degradation of the three polymers studied is the same as the relative resistance to gamma irradiation in air (so relative rankings of polymer resistance to ionizing radiation can be used as a relative ranking for assessing tritium compatibility and polymer selection); and (2) all three polymers changed the gas atmosphere during tritium exposure--UHMW-PE and Vespel{reg_sign} exposed to tritium formed H{sub 2} gas (UHMW-PE much more so), and PTFE exposed to tritium formed {sup 3}HF. This observation of forming {sup 3}HF supports the general concept of minimizing chlorofluorocarbon polymers in tritium systems.« less
Fluency heuristic: a model of how the mind exploits a by-product of information retrieval.
Hertwig, Ralph; Herzog, Stefan M; Schooler, Lael J; Reimer, Torsten
2008-09-01
Boundedly rational heuristics for inference can be surprisingly accurate and frugal for several reasons. They can exploit environmental structures, co-opt complex capacities, and elude effortful search by exploiting information that automatically arrives on the mental stage. The fluency heuristic is a prime example of a heuristic that makes the most of an automatic by-product of retrieval from memory, namely, retrieval fluency. In 4 experiments, the authors show that retrieval fluency can be a proxy for real-world quantities, that people can discriminate between two objects' retrieval fluencies, and that people's inferences are in line with the fluency heuristic (in particular fast inferences) and with experimentally manipulated fluency. The authors conclude that the fluency heuristic may be one tool in the mind's repertoire of strategies that artfully probes memory for encapsulated frequency information that can veridically reflect statistical regularities in the world. (c) 2008 APA, all rights reserved.
Lexical factors and cerebral regions influencing verbal fluency performance in MCI.
Clark, D G; Wadley, V G; Kapur, P; DeRamus, T P; Singletary, B; Nicholas, A P; Blanton, P D; Lokken, K; Deshpande, H; Marson, D; Deutsch, G
2014-02-01
To evaluate assumptions regarding semantic (noun), verb, and letter fluency in mild cognitive impairment (MCI) and Alzheimer disease (AD) using novel techniques for measuring word similarity in fluency lists and a region of interest (ROI) analysis of gray matter correlates. Fifty-eight individuals with normal cognition (NC, n=25), MCI (n=23), or AD (n=10) underwent neuropsychological tests, including 10 verbal fluency tasks (three letter tasks [F, A, S], six noun categories [animals, water creatures, fruits and vegetables, tools, vehicles, boats], and verbs). All pairs of words generated by each participant on each task were compared in terms of semantic (meaning), orthographic (spelling), and phonemic (pronunciation) similarity. We used mixed-effects logistic regression to determine which lexical factors were predictive of word adjacency within the lists. Associations between each fluency raw score and gray matter volumes in sixteen ROIs were identified by means of multiple linear regression. We evaluated causal models for both types of analyses to specify the contributions of diagnosis and various mediator variables to the outcomes of word adjacency and fluency raw score. Semantic similarity between words emerged as the strongest predictor of word adjacency for all fluency tasks, including the letter fluency tasks. Semantic similarity mediated the effect of cognitive impairment on word adjacency only for three fluency tasks employing a biological cue. Orthographic similarity was predictive of word adjacency for the A and S tasks, while phonemic similarity was predictive only for the S task and one semantic task (vehicles). The ROI analysis revealed different patterns of correlations among the various fluency tasks, with the most common associations in the right lower temporal and bilateral dorsal frontal regions. Following correction with gray matter volumes from the opposite hemisphere, significant associations persisted for animals, vehicles, and a composite nouns score in the left inferior frontal gyrus, but for letter A, letter S, and a composite FAS score in the right inferior frontal gyrus. These regressions also revealed a lateralized association of the left subcortical nuclei with all letter fluency scores and fruits and vegetables fluency, and an association of the right lower temporal ROI with letter A, FAS, and verb fluency. Gray matter volume in several bihemispheric ROIs (left dorsal frontal, right lower temporal, right occipital, and bilateral mesial temporal) mediated the relationship between cognitive impairment and fluency for fruits and vegetables. Gray matter volume in the right lower temporal ROI mediated the relationship between cognitive impairment and five fluency raw scores (animals, fruits and vegetables, tools, verbs, and the composite nouns score). Semantic memory exerts the strongest influence on word adjacency in letter fluency as well as semantic verbal fluency tasks. Orthography is a stronger influence than pronunciation. All types of fluency task raw scores (letter, noun, and verb) correlate with cerebral regions known to support verbal or nonverbal semantic memory. The findings emphasize the contribution of right hemisphere regions to fluency task performance, particularly for verb and letter fluency. The relationship between diagnosis and semantic fluency performance is mediated by semantic similarity of words and by gray matter volume in the right lower temporal region. Published by Elsevier Ltd.
Determination of Diffusion Parameters of CO2 Through Microporous PTFE Using a Potentiometric Method
NASA Astrophysics Data System (ADS)
Tarsiche, I.; Ciurchea, D.
Dk values at the diffusion of CO2 through microporous PTFE of 1 to 7 × 10- 7 cm2 s- 1 in the concentration range from 4 × 10- 4 to 0.22 g/l CO2 are determined using a simple, fast and reliable potentiometric method. The method is based on the least-squares fitting of the potential versus time response of a self made CO2 sensitive Severinghaus type sensor with PTFE as a gas-permeable membrane. The obtained results are in good agreement with other reported literature data, both experimental or calculated ones using molecular dynamics simulations. The proposed technique is very sensitive especially at low concentrations of gas and may be used for the study of other polymeric membranes too.
Fluoropolymer Dynamics: Effects of Perfluoromethyl Branches
NASA Astrophysics Data System (ADS)
Eby, R. K.; Holt, D. B.; Farmer, B. L.; Adams, D. D.
1997-03-01
Previous simulations of polytetrafluoroethylene (PTFE) in the solid state showed that the interaction and movement of helix reversals plays an important role in the dynamic behavior of this important polymer. Copolymers of TFE and hexafluoropropylene (HFP), which can be viewed as PTFE with perfluoromethyl (PFM) group branch defects, is also widely used. Molecular mechanics and dynamics calculations have been performed with PTFE chain clusters containing PFM branches to investigate the effect of these defects on the local crystalline environment (and vice versa) and on the motions and interactions of helix reversals. Initial results indicate that helix reversals are attracted to sites of PFM branches in a chain. Such an interaction will impede the motions of helix reversals and have an impact on macroscopic mechanical properties such as resistance to plastic deformation under shear.
Sexual-orientation-related differences in verbal fluency.
Rahman, Qazi; Abrahams, Sharon; Wilson, Glenn D
2003-04-01
This study examined the performance of 60 heterosexual men, 60 gay men, 60 heterosexual women, and 60 lesbians on 3 tests of verbal fluency known to show gender differences: letter, category, and synonym fluency. Gay men and lesbians showed opposite-sex shifts in their profile of scores. For letter fluency, gay men outperformed all other groups; lesbians showed the lowest scores. For category fluency, gay men and heterosexual women jointly outperformed lesbians and heterosexual men. Finally, gay men outperformed all other groups on synonym fluency, whereas lesbians and heterosexual men performed similarly. A difference between heterosexual men and women was demonstrated on category and synonym fluency only. The findings implicate within-sex differences in the functioning of the prefrontal and temporal cortices.
2014-01-01
Background The processing of verbal fluency tasks relies on the coordinated activity of a number of brain areas, particularly in the frontal and temporal lobes of the left hemisphere. Recent studies using functional magnetic resonance imaging (fMRI) to study the neural networks subserving verbal fluency functions have yielded divergent results especially with respect to a parcellation of the inferior frontal gyrus for phonemic and semantic verbal fluency. We conducted a coordinate-based activation likelihood estimation (ALE) meta-analysis on brain activation during the processing of phonemic and semantic verbal fluency tasks involving 28 individual studies with 490 healthy volunteers. Results For phonemic as well as for semantic verbal fluency, the most prominent clusters of brain activation were found in the left inferior/middle frontal gyrus (LIFG/MIFG) and the anterior cingulate gyrus. BA 44 was only involved in the processing of phonemic verbal fluency tasks, BA 45 and 47 in the processing of phonemic and semantic fluency tasks. Conclusions Our comparison of brain activation during the execution of either phonemic or semantic verbal fluency tasks revealed evidence for spatially different activation in BA 44, but not other regions of the LIFG/LMFG (BA 9, 45, 47) during phonemic and semantic verbal fluency processing. PMID:24456150
Brébion, Gildas; Stephan-Otto, Christian; Ochoa, Susana; Nieto, Lourdes; Contel, Montserrat; Usall, Judith
2018-01-01
Decreased processing speed in schizophrenia patients has been identified as a major impairment factor in various neuropsychological domains. Working memory span has been found to be involved in several deep or effortful cognitive processes. We investigated the impact that these 2 cognitive functions may have on phonological and semantic fluency in schizophrenia patients and healthy participants. Fifty-five patients with schizophrenia and 60 healthy participants were administered a neuropsychological battery including phonological and semantic fluency, working memory, and cognitive and motor speed. Regression analyses revealed that motor speed was related to phonological fluency in female patients, whereas cognitive speed was related to semantic fluency in male patients. In addition, working memory span was related to verbal fluency in women from both the patient and the healthy control groups. Decreased processing speed, but not decreased working memory span, accounted for the verbal fluency deficit in patients. Verbal fluency was inversely related to attention deficit in female patients and to negative symptoms in male patients. Decreased processing speed may be the main factor in verbal fluency impairment of patients. Further, the cognitive and clinical predictors of verbal fluency efficiency are different in men and women. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
Ambient Observations of the Soot Aging Process during the SHARP Intensive Field Campaign
NASA Astrophysics Data System (ADS)
Reed, C.; Collins, D. R.; Khalizov, A. F.; Zheng, J.; Zhang, R.
2009-12-01
Soot aerosols affect climate both directly through absorption of solar radiation and indirectly by potentially serving as cloud condensation nuclei. Among the sources of uncertainty surrounding the effects of soot aerosol on the environment is the lack of scientific insight into the soot aging process, in which soot particles develop a coating of secondary species such as sulfates, ammonium, nitrate, and organics. Such processes may alter the behavior of soot by modifying particle morphology over time leading to changes in chemical, physical and scattering properties of the aerosol. However, it is often difficult to quantify such processes in the ambient environment due to the complex composition and spatial and temporal variability of the atmospheric aerosol. In order to better understand the effects of the environment on soot particles, it is desirable to study the processes responsible for their transformation in the ambient air without influence from variability in source region and history prior to sampling. To achieve this, the overall soot aging process in the ambient environment was physically isolated utilizing environmental chambers. Chamber measurements were conducted on the Moody Tower at the University of Houston using The Ambient Aerosol Chamber for Evolution Studies (AACES) during the SHARP campaign. AACES is a roughly cubical chamber constructed of a rigid acrylic outer shell, which transmits UV radiation both in the UV-B and UV-A ranges. FEP Teflon lines the inside of the chamber on all sides and the top, while expanded-PTFE (ePTFE) Teflon is used on the bottom of the chamber. The fibrous structure of the ePTFE acts as a barrier to particulates, while allowing gas molecules to move virtually unimpeded from the surrounding air into the chamber, creating an environment inside the chamber that is initially free of particles and continuously mimics the local ambient air. In order to study the effects of the soot aging process, a non-premixed propane flame was used to generate a polydisperse fresh soot aerosol. Then, using a differential mobility analyzer, a monodisperse, uncharged soot aerosol was injected into the environmental chamber. Observations of particle concentration, size, hygroscopicity, effective density, and light extinction and scattering properties were carried out over time using a tandem differential mobility analyzer system, an aerosol particle mass analyzer, a nephelometer and a cavity ringdown spectrometer. Results from preliminary analysis of the data collected during the campaign will be presented.
Continuum modeling of charging process and piezoelectricity of ferroelectrets
NASA Astrophysics Data System (ADS)
Xu, Bai-Xiang; von Seggern, Heinz; Zhukov, Sergey; Gross, Dietmar
2013-09-01
Ferroelectrets in the form of electrically charged micro-porous foams exhibit a very large longitudinal piezoelectric coefficient d33. The structure has hence received wide application interests as sensors particularly in acoustic devices. During charging process, electrical breakdown (Paschen breakdown) takes place in the air pores of the foam and introduces free charge pairs. These charges are separated by electrostatic forces and relocated at the interfaces between the polymer and the electrically broken-down medium, where they are trapped quasistatically. The development of this trapped charge density along the interfaces is key for enabling the piezoelectricity of ferroelectrets. In this article, an internal variable based continuum model is proposed to calculate the charge density development at the interfaces, whereas a Maxwell stress based electromechanical model is used for the bulk behavior, i.e., of the polymer and of the medium where the Paschen breakdown takes place. In the modeling, the electrostatic forces between the separated charge pairs are included, as well as the influence of deformation of the solid layers. The material models are implemented in a nonlinear finite element scheme, which allows a detailed analysis of different geometries. A ferroelectret unit with porous expanded polytetrafluoroethylene (ePTFE) surrounded by fluorinated ethylene propylene is studied first. The simulated hysteresis curves of charge density at the surfaces and the calculated longitudinal piezoelectric constant are in good agreement with experimental results. Simulations show a strong dependency of the interface charge development and thus the remnant charges on the thicknesses of the layers and the permittivity of the materials. According to the calculated relation between d33 and the Young's modulus of ePTFE, the value of the Young's modulus of ePTFE is identified to be around 0.75 MPa, which lies well in the predicted range of 0.45 to 0.80 MPa, determined from the dielectric resonance spectra in the work of Zhang et al. [X. Q. Zhang et al., J. Appl. Phys. 108, 064113 (2010)]. To show the potential of the models, it is also applied to simulation of ferroelectrets with a lens shape. The results indicate that the electrical breakdown happens in a sequential manner, and the local piezoelectric coefficient varies with position. Thereby, the middle point on the surface exhibits the maximum d33. The simulation results obtained by the proposed models will provide insight for device optimization.
Zybutz, M D; Laurell, L; Rapoport, D A; Persson, G R
2000-03-01
Different types of barriers are used in guided tissue regenerative procedures. This prospective study compared resorbable citric acid ester softened polylactic acid membranes (RM) and non-resorbable expanded polytetrafluoroethylene (ePTFE) barriers (NRM) in GTR treatment of intrabony defects. 29 subjects were randomly assigned to the RM group or NRM group. Each patient received one GTR procedure. An open flap debridement (FD) was performed at another site 2 weeks later to evaluate healing potential. Clinical treatment outcomes were finally evaluated 12 months after surgery for changes of pocket depth PD, probing attachment level PAL, and probing bone level PBL, and radiographically for bone change using standardised radiographs. No differences in healing patters after surgery were found between patients in the 2 study groups as evaluated from the FD surgical procedures. NRM treated sites showed less signs of post-surgical inflammation during the 1st 4 weeks of healing than did RM treated sites (p<0.05). GTR-treated defects in the RM group, initially 7.0+/-2.2 mm deep, showed PD reduction of 3.3+/-2.2 mm, PAL gain of 2.4+/-1.8 mm, PBL gain of 2.4+/-3.7 mm (28%) and a radiographic bone fill of 2.3+/-2.4 mm. Defects treated with the NRM exhibited PD reduction of 3.1+/-2.1 mm, PAL gain of 2.4+/-0.8 mm, PBL gain of 2.2+/-1.7 mm (25%) and a radiographic bone fill of 3.3+/-2.2 mm. All improvements were statistically significant (p<0.01) but there was no difference between RM and NRM treatments for any of the efficacy variables. The results of this study indicated that there was no clinically significant difference in treatment outcomes following GTR treatment of intrabony defects with citric acid ester softened polylactic acid membranes as compared to ePTFE barriers. The overall mean inter-proximal vertical bone defect fill at 12 months as assessed from intra-oral radiographs was 44% of the original mean defect depth. Thus, no clinically significant difference in treatment outcomes was observed following GTR treatment of intrabony defects with citric acid ester softened polylactic acid membranes or ePTFE barriers.
Effect of gamma and neutron irradiation on the mechanical properties of Spectralon™ porous PTFE
Gourdin, William H.; Datte, Philip; Jensen, Wayne; ...
2016-07-21
Here, we establish a correspondence between the mechanical properties (maximum load and failure elongation) of Spectralon™ porous PTFE irradiated with 14 MeV neutrons and 1.17 and 1.33 MeV gammas from a cobalt-60 source. From this correspondence we infer that the effects of neutrons and gammas on this material are approximately equivalent for a given absorbed dose.
NASA Technical Reports Server (NTRS)
Herald, Stephen D.; Frisby, Paul M.; Davis, Samuel Eddie
2009-01-01
Safe and reliable seal materials for high-pressure oxygen systems sometimes appear to be extinct species when sought out by oxygen systems designers. Materials that seal well are easy to find, but these materials are typically incompatible with oxygen, especially in cryogenic liquid form. This incompatibility can result in seals that leak, or much worse, seals that easily ignite and burn during use. Materials that are compatible with oxygen are easy to find, such as the long list of compatible metals, but these metallic materials are limiting as seal materials. A material that seals well and is oxygen compatible has been the big game in the designer's safari. Scientists at the Materials Combustion Research Facility (MCRF), part of NASA/Marshall Space Flight Center (MSFC), are constantly searching for better materials and processes to improve the safety of oxygen systems. One focus of this effort is improving the characteristics of polymers used in the presence of an oxygen enriched environment. Very few systems can be built which contain no polymeric materials; therefore, materials which have good impact resistance, low heat of combustion, high auto-ignition temperature and that maintain good mechanical properties are essential. The scientists and engineers at the Materials Combustion Research Facility, in cooperation with seal suppliers, are currently testing a new formulation of polytetrafluoroethylene (PTFE) with Brass filler. This Brass-filled PTFE is showing great promise as a seal and seat material for high pressure oxygen systems. Early research has demonstrated very encouraging results, which could rank this material as one of the best fluorinated polymers ever tested. This paper will compare the data obtained for Brass-filled PTFE with other fluorinated polymers, such as TFE-Teflon (PTFE) , Kel-F 81, Viton A, Viton A-500, Fluorel , and Algoflon . A similar metal filled fluorinated polymer, Salox-M , was tested in comparison to Brass-filled PTFE to demonstrate the importance of the metal chosen and relative percentage of filler. General conclusions on the oxygen compatibility of this formulation are drawn, with an emphasis on comparing and contrasting the materials performance to the performance of the current state-of-the-art oxygen compatible polymers.
Oxygen electrode bifunctional electrocatalyst NiCo2O4 spinel
NASA Technical Reports Server (NTRS)
Fielder, William L.; Singer, Joseph
1988-01-01
A significant increase in energy density may be possible if a two-unit alkaline regenerative H2-O2 fuel cell is replaced with a single-unit system that uses passive means for H2O transfer and thermal control. For this single-unit system, new electrocatalysts for the O2 electrode will be required which are not only bifunctionally active but also chemically and electrochemically stable between the voltage range of about 0.7 and 1.5 V. NiCo2O4 spinel is reported to have certain characteristics that make it useful for a study of electrode fabrication techniques. High surface area NiCo2O4 powder was fabricated into unsupported, bifunctional, PTFE-bonded, porous gas fuel cell electrodes by commercial sources using varying PTFE contents and sintering temperatures. The object of this study is to measure the bifunctional activities of these electrodes and to observe what performance differences might result from different commercial electrode fabricators. O2 evolution and O2 reduction data were obtained at 80 C (31 percent KOH). An irreversible reaction (i.e., aging) occurred during O2 evolution at potentials greater than about 1.5 V. Anodic Tafel slopes of 0.06 and 0.12 V/decade were obtained for the aged electrodes. Within the range of 15 to 25 percent, the PTFE content was not a critical parameter for optimizing the electrode for O2 evolution activity. Sintering temperatures between 300 and 340 C may be adequate but heating at 275 C may not be sufficient to properly sinter the PTFE-NiCo2O4 mixture. Electrode disintegration was observed during O2 reduction. Transport of O2 to the NiCo2O4 surface became prohibitive at greater than about -0.02 A/sq cm. Cathodic Tafel slopes of -0.6 and -0.12 V/decade were assumed for the O2 reduction process. A PTFE content of 25 percent (or greater) appears to be preferable for sintering the PTFE-NiCo2O4 mixture.
Conceptual fluency increases recollection: behavioral and electrophysiological evidence
Wang, Wei; Li, Bingbing; Gao, Chuanji; Xu, Huifang; Guo, Chunyan
2015-01-01
It is widely established that fluency can contribute to recognition memory. Previous studies have found that enhanced fluency increases familiarity, but not recollection. The present study was motivated by a previous finding that conceptual priming affected recollection. We used event-related potentials to investigate the electrophysiological correlates of these effects with conceptually related two-character Chinese words. We found that previous conceptual priming effects on conceptual fluency only increased the incidence of recollection responses. We also found that enhanced conceptual fluency was associated with N400 attenuation, which was also correlated with the behavioral indicator of recollection. These results suggest that the N400 effect might be related to the impact of conceptual fluency on recollection recognition. These study findings provide further evidence for the relationship between fluency and recollection. PMID:26175678
Gauvreau, Virginie; Chevallier, Pascale; Vallières, Karine; Petitclerc, Eric; Gaudreault, René C; Laroche, Gaétan
2004-01-01
This study presents two-step and multistep reactions for modifying the surface of plasma-functionalized poly(tetrafluoroethylene) (PTFE) surfaces for subsequent conjugation of biologically relevant molecules. First, PTFE films were treated by a radiofrequency glow discharge (RFGD) ammonia plasma to introduce amino groups on the fluoropolymer surface. This plasma treatment is well optimized and allows the incorporation of a relative surface concentration of approximately 2-3.5% of amino groups, as assessed by chemical derivatization followed by X-ray photoelectron spectroscopy (XPS). In a second step, these amino groups were further reacted with various chemical reagents to provide the surface with chemical functionalities such as maleimides, carboxylic acids, acetals, aldehydes, and thiols, that could be used later on to conjugate a wide variety of biologically relevant molecules such as proteins, DNA, drugs, etc. In the present study, glutaric and cis-aconitic anhydrides were evaluated for their capability to provide carboxylic functions to the PTFE plasma-treated surface. Bromoacetaldehyde diethylacetal was reacted with the aminated PTFE surface, providing a diethylacetal function, which is a latent form of aldehyde functionality. Reactions with cross-linkers such as sulfo-succinimidyl derivatives (sulfo-SMCC, sulfo-SMPB) were evaluated to provide a highly reactive maleimide function suitable for further chemical reactions with thiolated molecules. Traut reagent (2-iminothiolane) was also conjugated to introduce a thiol group onto the fluoropolymer surface. PTFE-modified surfaces were analyzed by XPS with a particular attention to quantify the extent of the reactions that occurred on the polymer. Finally, surface immobilization of fibronectin performed using either glutaric anhydride or sulfo-SMPB activators demonstrated the importance of selecting the appropriate conjugation strategy to retain the protein biological activity.
Microexplosions and ignition dynamics in engineered aluminum/polymer fuel particles
Rubio, Mario A.; Gunduz, I. Emre; Groven, Lori J.; ...
2016-11-11
Aluminum particles are widely used as a metal fuel in solid propellants. However, poor combustion efficiencies and two-phase flow losses result due in part to particle agglomeration. Engineered composite particles of aluminum (Al) with inclusions of polytetrafluoroethylene (PTFE) or low-density polyethylene (LDPE) have been shown to improve ignition and yield smaller agglomerates in solid propellants, recently. Reductions in agglomeration were attributed to internal pressurization and fragmentation (microexplosions) of the composite particles at the propellant surface. We explore the mechanisms responsible for microexplosions in order to better understand the combustion characteristics of composite fuel particles. Single composite particles of Al/PTFE andmore » Al/LDPE with diameters between 100 and 1200 µm are ignited on a substrate to mimic a burning propellant surface in a controlled environment using a CO 2 laser in the irradiance range of 78–7700 W/cm 2. Furthermore, the effects of particle size, milling time, and inclusion content on the resulting ignition delay, product particle size distributions, and microexplosion tendencies are reported. For example particles with higher PTFE content (30 wt%) had laser flux ignition thresholds as low as 77 W/cm 2, exhibiting more burning particle dispersion due to microexplosions compared to the other materials considered. Composite Al/LDPE particles exhibit relatively high ignition thresholds compared to Al/PTFE particles, and microexplosions were observed only with laser fluxes above 5500 W/cm 2 due to low LDPE reactivity with Al resulting in negligible particle self-heating. However, results show that microexplosions can occur for Al containing both low and high reactivity inclusions (LDPE and PTFE, respectively) and that polymer inclusions can be used to tailor the ignition threshold. Furthermore, this class of modified metal particles shows significant promise for application in many different energetic materials that use metal fuels.« less
Attenuation Drift in the Micro-Computed Tomography System at LLNL
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dooraghi, Alex A.; Brown, William; Seetho, Isaac
2016-01-12
The maximum allowable level of drift in the linear attenuation coefficients (μ) for a Lawrence Livermore National Laboratory (LLNL) micro-computed tomography (MCT) system was determined to be 0.1%. After ~100 scans were acquired during the period of November 2014 to March 2015, the drift in μ for a set of six reference materials reached or exceeded 0.1%. Two strategies have been identified to account for or correct the drift. First, normalizing the 160 kV and 100 kV μ data by the μ of water at the corresponding energy, in contrast to conducting normalization at the 160 kV energy only, significantlymore » compensates for measurement drift. Even after the modified normalization, μ of polytetrafluoroethylene (PTFE) increases linearly with scan number at an average rate of 0.00147% per scan. This is consistent with PTFE radiation damage documented in the literature. The second strategy suggested is the replacement of the PTFE reference with fluorinated ethylene propylene (FEP), which has the same effective atomic number (Ze) and electron density (ρe) as PTFE, but is 10 times more radiation resistant. This is important as effective atomic number and electron density are key parameters in analysis. The presence of a material with properties such as PTFE, when taken together with the remaining references, allows for a broad range of the (Ze, ρe) feature space to be used in analysis. While FEP is documented as 10 times more radiation resistant, testing will be necessary to assess how often, if necessary, FEP will need to be replaced. As radiation damage to references has been observed, it will be necessary to monitor all reference materials for radiation damage to ensure consistent x-ray characteristics of the references.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rubio, Mario A.; Gunduz, I. Emre; Groven, Lori J.
Aluminum particles are widely used as a metal fuel in solid propellants. However, poor combustion efficiencies and two-phase flow losses result due in part to particle agglomeration. Engineered composite particles of aluminum (Al) with inclusions of polytetrafluoroethylene (PTFE) or low-density polyethylene (LDPE) have been shown to improve ignition and yield smaller agglomerates in solid propellants, recently. Reductions in agglomeration were attributed to internal pressurization and fragmentation (microexplosions) of the composite particles at the propellant surface. We explore the mechanisms responsible for microexplosions in order to better understand the combustion characteristics of composite fuel particles. Single composite particles of Al/PTFE andmore » Al/LDPE with diameters between 100 and 1200 µm are ignited on a substrate to mimic a burning propellant surface in a controlled environment using a CO 2 laser in the irradiance range of 78–7700 W/cm 2. Furthermore, the effects of particle size, milling time, and inclusion content on the resulting ignition delay, product particle size distributions, and microexplosion tendencies are reported. For example particles with higher PTFE content (30 wt%) had laser flux ignition thresholds as low as 77 W/cm 2, exhibiting more burning particle dispersion due to microexplosions compared to the other materials considered. Composite Al/LDPE particles exhibit relatively high ignition thresholds compared to Al/PTFE particles, and microexplosions were observed only with laser fluxes above 5500 W/cm 2 due to low LDPE reactivity with Al resulting in negligible particle self-heating. However, results show that microexplosions can occur for Al containing both low and high reactivity inclusions (LDPE and PTFE, respectively) and that polymer inclusions can be used to tailor the ignition threshold. Furthermore, this class of modified metal particles shows significant promise for application in many different energetic materials that use metal fuels.« less
Pascual, Gemma; Hernández-Gascón, Belén; Rodríguez, Marta; Sotomayor, Sandra; Peña, Estefania; Calvo, Begoña; Bellón, Juan M
2012-11-01
Although heavyweight (HW) or lightweight (LW) polypropylene (PP) meshes are widely used for hernia repair, other alternatives have recently appeared. They have the same large-pore structure yet are composed of polytetrafluoroethylene (PTFE). This study compares the long-term (3 and 6 months) behavior of meshes of different pore size (HW compared with LW) and composition (PP compared with PTFE). Partial defects were created in the lateral wall of the abdomen in New Zealand White rabbits and then repaired by the use of a HW or LW PP mesh or a new monofilament, large-pore PTFE mesh (Infinit). At 90 and 180 days after implantation, tissue incorporation, gene and protein expression of neocollagens (reverse transcription-polymerase chain reaction/immunofluorescence), macrophage response (immunohistochemistry), and biomechanical strength were determined. Shrinkage was measured at 90 days. All three meshes induced good host tissue ingrowth, yet the macrophage response was significantly greater in the PTFE implants (P < .05). Collagen 1/3 mRNA levels failed to vary at 90 days yet in the longer term, the LW meshes showed the reduced genetic expression of both collagens (P < .05) accompanied by increased neocollagen deposition, indicating more efficient mRNA translation. After 90-180 days of implant, tensile strengths and elastic modulus values were similar for all 3 implants (P > .05). Host collagen deposition is mesh pore size dependent whereas the macrophage response induced is composition dependent with a greater response shown by PTFE. In the long term, macroporous meshes show comparable biomechanical behavior regardless of their pore size or composition. Copyright © 2012 Mosby, Inc. All rights reserved.
Zhao, Jing; Kwok, Rosa K. W.; Liu, Menglian; Liu, Hanlong; Huang, Chen
2017-01-01
Reading fluency is a critical skill to improve the quality of our daily life and working efficiency. The majority of previous studies focused on oral reading fluency rather than silent reading fluency, which is a much more dominant reading mode that is used in middle and high school and for leisure reading. It is still unclear whether the oral and silent reading fluency involved the same underlying skills. To address this issue, the present study examined the relationship between the visual rapid processing and Chinese reading fluency in different modes. Fifty-eight undergraduate students took part in the experiment. The phantom contour paradigm and the visual 1-back task were adopted to measure the visual rapid temporal and simultaneous processing respectively. These two tasks reflected the temporal and spatial dimensions of visual rapid processing separately. We recorded the temporal threshold in the phantom contour task, as well as reaction time and accuracy in the visual 1-back task. Reading fluency was measured in both single-character and sentence levels. Fluent reading of single characters was assessed with a paper-and-pencil lexical decision task, and a sentence verification task was developed to examine reading fluency on a sentence level. The reading fluency test in each level was conducted twice (i.e., oral reading and silent reading). Reading speed and accuracy were recorded. The correlation analysis showed that the temporal threshold in the phantom contour task did not correlate with the scores of the reading fluency tests. Although, the reaction time in visual 1-back task correlated with the reading speed of both oral and silent reading fluency, the comparison of the correlation coefficients revealed a closer relationship between the visual rapid simultaneous processing and silent reading. Furthermore, the visual rapid simultaneous processing exhibited a significant contribution to reading fluency in silent mode but not in oral reading mode. These findings suggest that the underlying mechanism between oral and silent reading fluency is different at the beginning of the basic visual coding. The current results also might reveal a potential modulation of the language characteristics of Chinese on the relationship between visual rapid processing and reading fluency. PMID:28119663
Zhao, Jing; Kwok, Rosa K W; Liu, Menglian; Liu, Hanlong; Huang, Chen
2016-01-01
Reading fluency is a critical skill to improve the quality of our daily life and working efficiency. The majority of previous studies focused on oral reading fluency rather than silent reading fluency, which is a much more dominant reading mode that is used in middle and high school and for leisure reading. It is still unclear whether the oral and silent reading fluency involved the same underlying skills. To address this issue, the present study examined the relationship between the visual rapid processing and Chinese reading fluency in different modes. Fifty-eight undergraduate students took part in the experiment. The phantom contour paradigm and the visual 1-back task were adopted to measure the visual rapid temporal and simultaneous processing respectively. These two tasks reflected the temporal and spatial dimensions of visual rapid processing separately. We recorded the temporal threshold in the phantom contour task, as well as reaction time and accuracy in the visual 1-back task. Reading fluency was measured in both single-character and sentence levels. Fluent reading of single characters was assessed with a paper-and-pencil lexical decision task, and a sentence verification task was developed to examine reading fluency on a sentence level. The reading fluency test in each level was conducted twice (i.e., oral reading and silent reading). Reading speed and accuracy were recorded. The correlation analysis showed that the temporal threshold in the phantom contour task did not correlate with the scores of the reading fluency tests. Although, the reaction time in visual 1-back task correlated with the reading speed of both oral and silent reading fluency, the comparison of the correlation coefficients revealed a closer relationship between the visual rapid simultaneous processing and silent reading. Furthermore, the visual rapid simultaneous processing exhibited a significant contribution to reading fluency in silent mode but not in oral reading mode. These findings suggest that the underlying mechanism between oral and silent reading fluency is different at the beginning of the basic visual coding. The current results also might reveal a potential modulation of the language characteristics of Chinese on the relationship between visual rapid processing and reading fluency.
Chesters, Jennifer; Möttönen, Riikka; Watkins, Kate E
2018-04-01
See Crinion (doi:10.1093/brain/awy075) for a scientific commentary on this article.Stuttering is a neurodevelopmental condition affecting 5% of children, and persisting in 1% of adults. Promoting lasting fluency improvement in adults who stutter is a particular challenge. Novel interventions to improve outcomes are of value, therefore. Previous work in patients with acquired motor and language disorders reported enhanced benefits of behavioural therapies when paired with transcranial direct current stimulation. Here, we report the results of the first trial investigating whether transcranial direct current stimulation can improve speech fluency in adults who stutter. We predicted that applying anodal stimulation to the left inferior frontal cortex during speech production with temporary fluency inducers would result in longer-lasting fluency improvements. Thirty male adults who stutter completed a randomized, double-blind, controlled trial of anodal transcranial direct current stimulation over left inferior frontal cortex. Fifteen participants received 20 min of 1-mA stimulation on five consecutive days while speech fluency was temporarily induced using choral and metronome-timed speech. The other 15 participants received the same speech fluency intervention with sham stimulation. Speech fluency during reading and conversation was assessed at baseline, before and after the stimulation on each day of the 5-day intervention, and at 1 and 6 weeks after the end of the intervention. Anodal stimulation combined with speech fluency training significantly reduced the percentage of disfluent speech measured 1 week after the intervention compared with fluency intervention alone. At 6 weeks after the intervention, this improvement was maintained during reading but not during conversation. Outcome scores at both post-intervention time points on a clinical assessment tool (the Stuttering Severity Instrument, version 4) also showed significant improvement in the group receiving transcranial direct current stimulation compared with the sham group, in whom fluency was unchanged from baseline. We conclude that transcranial direct current stimulation combined with behavioural fluency intervention can improve fluency in adults who stutter. Transcranial direct current stimulation thereby offers a potentially useful adjunct to future speech therapy interventions for this population, for whom fluency therapy outcomes are currently limited.
Predicting verbal fluency using Word Reading: Implications for premorbid functioning.
Davis, Andrew S; Finch, W Holmes; Drapeau, Christopher; Nogin, Margarita; E Moss, Lauren; Moore, Brittney
2016-01-01
The estimation of premorbid general intellectual functioning using word reading tests has a rich history of validation and is a common assessment practice for neuropsychologists. What is less well-researched is the approach used to estimate premorbid functioning of non-intellectual domains, such as executive functions, including verbal fluency. The current study evaluated this relationship with 41 adult college students who completed the Word Reading subtest of the Wechsler Individual Achievement Test-Second Edition (WIAT-II) and the Verbal Fluency test from the Delis-Kaplan Executive Function System (D-KEFS). Path analysis indicated that only Letter Fluency (a measure of phonemic fluency) was statistically significantly related to Word Reading and the relationship was somewhat weak. The relationship between Category Fluency (a measure of semantic fluency) and Category Switching (a measure of verbal fluency cognitive set-shifting) to Word Reading was nonsignificant. Participants also completed the Wechsler Adult Intelligence Scale-Third Edition (WAIS-III), and as expected a strong relationship was found between Word Reading and the Verbal IQ (VIQ), Performance IQ (PIQ), and Full Scale Intelligence Quotient (FSIQ). Results of this study strongly suggest that caution be exercised when extrapolating an estimate of premorbid verbal fluency abilities from measures of word reading.
Messinis, L; Kosmidis, M H; Vlahou, C; Malegiannaki, A C; Gatzounis, G; Dimisianos, N; Karra, A; Kiosseoglou, G; Gourzis, P; Papathanasopoulos, P
2013-01-01
The strategies used to perform a verbal fluency task appear to be reflective of cognitive abilities necessary for successful daily functioning. In the present study, we explored potential differences in verbal fluency strategies (switching and clustering) used to maximize word production by patients with relapsing-remitting multiple sclerosis (RRMS) versus patients with secondary progressive multiple sclerosis (SPMS). We further assessed impairment rates and potential differences in the sensitivity and specificity of phonological versus semantic verbal fluency tasks in discriminating between those with a diagnosis of MS and healthy adults. We found that the overall rate of impaired verbal fluency in our MS sample was consistent with that in other studies. However, we found no differences between types of MS (SPMS, RRMS), on semantic or phonological fluency word production, or the strategies used to maximize semantic fluency. In contrast, we found that the number of switches differed significantly in the phonological fluency task between the SPMS and RRMS subtypes. The clinical utility of semantic versus phonological fluency in discriminating MS patients from healthy controls did not indicate any significant differences. Further, the strategies used to maximize performance did not differentiate MS subgroups or MS patients from healthy controls.
Effect of X-ray flux on polytetrafluoroethylene in X-ray photoelectron spectroscopy
NASA Technical Reports Server (NTRS)
Wheeler, D. R.; Pepper, S. V.
1982-01-01
The effect of the X-ray flux in X-ray photoelectron spectroscopy (STAT) on the constitution of the polytetrafluoroethylene (PTFE) surface has been examined. The radiation dose rate for our specimen was about 10 to the 7th rad/s. The structure, magnitude and binding energy of the C(1s) and F(1s) features of the XPS spectrum and the mass spectrum of gaseous species evolved during irradiation are observed. The strong time dependence of these signals over a period of several hours indicated that the surface constitution of PTFE is greatly affected by this level of radiation dose. The results are consistent with the development of a heavily cross-linked or branched structure in the PTFE surface region and the evolution of short chain fragments into the gas phase.
Omniphobic Membrane for Robust Membrane Distillation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, SH; Nejati, S; Boo, C
2014-11-01
In this work, we fabricate an omniphobic microporous membrane for membrane distillation (MD) by modifying a hydrophilic glass fiber membrane with silica nanoparticles followed by surface fluorination and polymer coating. The modified glass fiber membrane exhibits an anti-wetting property not only against water but also against low surface tension organic solvents that easily wet a hydrophobic polytetrafluoroethylene (PTFE) membrane that is commonly used in MD applications. By comparing the performance of the PTFE and omniphobic membranes in direct contact MD experiments in the presence of a surfactant (sodium dodecyl sulfate, SDS), we show that SDS wets the hydrophobic PTFE membranemore » but not the omniphobic membrane. Our results suggest that omniphobic membranes are critical for MD applications with feed waters containing surface active species, such as oil and gas produced water, to prevent membrane pore wetting.« less
NASA Technical Reports Server (NTRS)
Eigenbrode, J. L.; McAdam, A.; Franz, H.; Freissinet, C.; Bower, H.; Floyd, M.; Conrad, P.; Mahaffy, P.; Feldman, J.; Hurowitz, J.;
2013-01-01
Polytetrafluoroethylene (PTFE or trade name: Teflon by Dupont Co.) has been detected in rocks drilled during terrestrial testing of the Mars Science Laboratory (MSL) drilling hardware. The PTFE in sediments is a wear product of the seals used in the Drill Bit Assemblies (DBAs). It is expected that the drill assembly on the MSL flight model will also shed Teflon particles into drilled samples. One of the primary goals of the Sample Analysis at Mars (SAM) instrument suite on MSL is to test for the presence of martian organics in samples. Complications introduced by the potential presence of PTFE in drilled samples to the SAM evolved gas analysis (EGA or pyrolysisquadrupole mass spectrometry, pyr-QMS) and pyrolysis- gas chromatography mass spectrometry (Pyr- GCMS) experiments was investigated.
NASA Astrophysics Data System (ADS)
Gamini, Suresh; Vasu, V.; Bose, Suryasarathi
2017-04-01
In the current study, PTFE (polytetrafluroethylene) matrix is reinforced with different wt% (2%-10%) of Halloysite nanotubes (HNTs). PTFE samples are fabricated with 2 wt% increment and are designated from ‘B’to ‘F’ and designation ‘A’ refers to neat PTFE. Thermal and mechanical characterization of the fabricated composites is studied. The calorimetric measurements showed enhanced degree of crystallinity of the nanocomposites, which is from 57.83% to 74.7%. The dynamic mechanical analysis results have shown enhanced storage modulus and loss modulus and reduced damping behaviour, without affecting glass transition temperature. Moreover, significant improvements in mechanical properties are observed from the experimental results. The results are discussed and validated with the existing literature. The phase and the fracture morphology of the nanocomposites is studied using scanning electron microscope and discussed herein.
Simpson, Ian Craig; Dumitrache, Cristina Gabriela; Calet, Nuria
2018-04-10
Depression and loneliness are highly prevalent in old age. Moreover these mental health symptoms adversely affect the verbal fluency of the elderly. We examined the relationship between depression and loneliness with verbal fluency in people aged 50 years or older. Research data were collected during the pilot study of the Longitudinal Aging Study in Spain (ELES) in which a representative sample of non-institutionalized Spanish older people was assessed. Here, the cross-sectional data for 962 participants were analysed using hierarchical regressions, controlling for age, education level, overall cognitive functioning, social networks and satisfaction with family. Higher levels of cognitive functioning were associated with higher verbal fluency. Females showed higher levels of phonological fluency. Neither depression nor loneliness were significant predictors of phonological fluency but loneliness was a significant predictor of semantic fluency. For mild levels of loneliness, the rate of decline in semantic fluency slows in the oldest ages. In contrast, for severe loneliness the rate of decline in semantic fluency increases in the oldest ages. Depressive symptoms, loneliness and cognitive impairment are all prominent in ageing and therefore their impact on ageing needs to be better understood. Early detection of loneliness, along with the implementation of intervention for individuals diagnosed with loneliness is advisable in order to avoid negative repercussions for the verbal fluency of these individuals.
Verbal Fluency Performance in Amnestic MCI and Older Adults with Cognitive Complaints
Nutter-Upham, Katherine E.; Saykin, Andrew J.; Rabin, Laura A.; Roth, Robert M.; Wishart, Heather A.; Pare, Nadia; Flashman, Laura A.
2009-01-01
Verbal fluency tests are employed regularly during neuropsychological assessments of older adults, and deficits are a common finding in patients with Alzheimer’s disease (AD). Little extant research, however, has investigated verbal fluency ability and subtypes in preclinical stages of neurodegenerative disease. We examined verbal fluency performance in 107 older adults with amnestic mild cognitive impairment (MCI, n = 37), cognitive complaints (CC, n = 37) despite intact neuropsychological functioning, and demographically-matched healthy controls (HC, n = 33). Participants completed fluency tasks with letter, semantic category, and semantic switching constraints. Both phonemic and semantic fluency were statistically (but not clinically) reduced in amnestic MCI relative to cognitively intact older adults, indicating subtle changes in both the quality of the semantic store and retrieval slowing. Investigation of the underlying constructs of verbal fluency yielded two factors: Switching (including switching and shifting tasks) and Production (including letter, category, and action naming tasks), and both factors discriminated MCI from HC albeit to different degrees. Correlational findings further suggested that all fluency tasks involved executive control to some degree, while those with an added executive component (i.e., switching and shifting) were less dependent on semantic knowledge. Overall, our findings highlight the importance of including multiple verbal fluency tests in assessment batteries targeting preclinical dementia populations and suggest that individual fluency tasks may tap specific cognitive processes. PMID:18339515
Reading component skills of learners in adult basic education.
MacArthur, Charles A; Konold, Timothy R; Glutting, Joseph J; Alamprese, Judith A
2010-01-01
The purposes of this study were to investigate the reliability and construct validity of measures of reading component skills with a sample of adult basic education (ABE) learners, including both native and nonnative English speakers, and to describe the performance of those learners on the measures. Investigation of measures of reading components is needed because available measures were neither developed for nor normed on ABE populations or with nonnative speakers of English. The study included 486 students, 334 born or educated in the United States (native) and 152 not born or educated in the United States (nonnative) but who spoke English well enough to participate in English reading classes. All students had scores on 11 measures covering five constructs: decoding, word recognition, spelling, fluency, and comprehension. Confirmatory factor analysis (CFA) was used to test three models: a two-factor model with print and meaning factors; a three-factor model that separated out a fluency factor; and a five-factor model based on the hypothesized constructs. The five-factor model fit best. In addition, the CFA model fit both native and nonnative populations equally well without modification, showing that the tests measure the same constructs with the same accuracy for both groups. Group comparisons found no difference between the native and nonnative samples on word recognition, but the native sample scored higher on fluency and comprehension and lower on decoding than did the nonnative sample. Students with self-reported learning disabilities scored lower on all reading components. Differences by age and gender were also analyzed.
Facilitating English-Language Learners' Oral Reading Fluency with Digital Pen Technology
ERIC Educational Resources Information Center
Chen, Chih-Ming; Tan, Chia-Chen; Lo, Bey-Jane
2016-01-01
Oral reading fluency is an indicator of overall reading competence. Many studies have claimed that repeated reading can promote oral reading fluency. Currently, novel Web- or computer-based reading technologies offer interactive digital materials that promote English oral reading fluency using the repeated reading strategy; however, paper-based…
Accuracy vs. Fluency: Which Comes First in ESL Instruction?
ERIC Educational Resources Information Center
Ebsworth, Miriam Eisenstein
1998-01-01
Discusses the debate over fluency versus accuracy in teaching English-as-a-Second-Language (ESL). Defines fluency and accuracy; examines alternative approaches (meaning first, accuracy first, and accuracy and fluency from the beginning); evaluates the alternatives; and highlights implications for teaching ESL. A sidebar presents an accuracy and…
Why Reading Fluency Should Be Hot
ERIC Educational Resources Information Center
Rasinski, Timothy V.
2012-01-01
This article explores problems that have surfaced in the teaching of reading fluency and how teachers and reading coaches can resolve those problems. Specific issues addressed include reading fluency being defined as reading fast and instruction that is focused on having students read fast, reading fluency viewed as solely and oral reading…
Reading Fluency Interventions That Work in High-Poverty Schools
ERIC Educational Resources Information Center
Fowers-Coils, Ashley
2016-01-01
This study measured the impact of targeted reading interventions on improving reading fluency for second-grade students as indicated by their performance on a statewide standardized assessment of reading fluency proficiency. Reading fluency scores for students who received intervention in second grade were measured again in their third-grade year…
The European Clinical Specialization on Fluency Disorders (ECSF)
ERIC Educational Resources Information Center
Eggers, Kurt; Leahy, Margaret
2011-01-01
The European Clinical Specialization on Fluency Disorders (ECSF) project consists of one-year post-qualification fluency specialization training and a harmonized graduate fluency program. It was developed by eight European universities/colleges to provide the means whereby graduates would meet comparable standards of competence to practice in the…
Silent Reading Fluency Using Underlining: Evidence for an Alternative Method of Assessment
ERIC Educational Resources Information Center
Price, Katherine W.; Meisinger, Elizabeth B.; Louwerse, Max M.; D'Mello, Sidney K.
2012-01-01
Assessing silent reading fluency in classroom environments is challenging. This article reports on a method of assessing silent reading using underlining, an approach that solves many problems other silent reading fluency assessment measures face. This method computationally monitors readers' silent reading fluency by the speed they underline…
NASA Astrophysics Data System (ADS)
Hopp, B.; Geretovszky, Zs.; Bertóti, I.; Boyd, I. W.
2002-01-01
Poly(tetrafluoroethylene) (PTFE) is notable for its non-adhesive and non-reactive properties. A number of technologies can potentially benefit from the application of PTFE, but these characteristics restrict the ability to structuring its surface. In this paper, we present results on two ultraviolet photon assisted treatments of PTFE. The originally poor adhesion was significantly improved by both 172 nm excimer lamp and 193 nm excimer laser assisted surface treatments. While Xe2∗ lamp irradiation, applied in a modest vacuum environment, was sufficient by itself to improve adhesion, the ArF laser process was only effective when the irradiated interface was in contact with 1,2-diaminoethane photoreagent. It was found that the tensile strength of an epoxy resin glued interface created on treated surfaces depended strongly on the applied number of laser pulses and lamp irradiation time. Laser treatment caused fast tensile strength increase during the first 50-500 pulses, while after this it saturates slowly at about 5.5 MPa in the 500-2500 pulse domain. The excimer lamp irradiation resulted in a maximum tensile strength of approximately 10 MPa after 2 min irradiation time which reduced to about 65% of the peak value at longer times.
García Medina, J; Lacasa Pérez, N; Muray Cases, S; Pérez Garrido, I; García Medina, V
2009-01-01
The purpose of this paper is to communicate our experience in the salvage of thrombosed haemodialysis vascular accesses using interventional radiology techniques. In the last four years, we have treated, by radiological means, 101 thrombosed haemodialysis vascular accesses. There were 44 autologous arteriovenous fistulas (43.56%) and 57 PTFE grafts (56.44%). There were 69 men (68.3%) and 32 women (31.7%). The mean age was 67.73 years (range 33-84). The mean vascular access age was 23.79 months (range 1-132). Manual catheter-directed aspiration was used. Fragmented, triturated or pushed the thrombus against the pulmonary circulation was avoided in all cases. 78 accesses were salvaged (77.2%). Autologous fistulas average and PTFE grafts success rate were 84.44% and 71.42% respectively. Angioplasty in one or more lesions after thromboaspiration was performed in all accesses, except six (5.9%). Metallic endoprostheses were implanted in 14 accesses (13.9%). Mean follow-up was 9 months (range 0-44). Primary patency was 42.3% +/- 5 at 6 months and 32% +/- 4 at one year. Autologous fistulas patency was better than PTFE grafts patency (p < or =0,05). Our results suggest thrombosed autologous arteriovenous fistulas salvage is better than PTFE grafts. This justifies interventional radiology techniques in these situations.
Mostafa, M. G.; Zhu, Bo; Cran, Marlene; Dow, Noel; Milne, Nicholas; Desai, Dilip
2017-01-01
Meat rendering operations produce stick water waste which is rich in proteins, fats, and minerals. Membrane distillation (MD) may further recover water and valuable solids, but hydrophobic membranes are contaminated by the fats. Here, commercial hydrophobic polytetrafluorethylene (PTFE) membranes with a hydrophilic polyurethane surface layer (PU-PTFE) are used for the first time for direct contact MD (DCMD) on real poultry, fish, and bovine stick waters. Metal membrane microfiltration (MMF) was also used to capture fats prior to MD. Although the standard hydrophobic PTFE membranes failed rapidly, PU-PTFE membranes effectively processed all stick water samples to colourless permeate with sodium rejections >99%. Initial clean solution fluxes 5–6 L/m2/h declined to less than half during short 40% water recovery tests for all stick water samples. Fish stick water uniquely showed reduced fouling and up to 78% water recovery. Lost flux was easily restored by rinsing the membrane with clean water. MMF prior to MD removed 92% of fats, facilitating superior MD performance. Differences in fouling between stick waters were attributed to temperature polarisation from higher melt temperature fats and relative proportions to proteins. Hydrophilic coated MD membranes are applicable to stick water processing but further studies should consider membrane cleaning and longer-term stability. PMID:28961203
NASA Astrophysics Data System (ADS)
Andisheh-Tadbir, Mehdi; Orfino, Francesco P.; Kjeang, Erik
2016-04-01
Modern hydrogen powered polymer electrolyte fuel cells (PEFCs) utilize a micro-porous layer (MPL) consisting of carbon nanoparticles and polytetrafluoroethylene (PTFE) to enhance the transport phenomena and performance while reducing cost. However, the underlying mechanisms are not yet completely understood due to a lack of information about the detailed MPL structure and properties. In the present work, the 3D phase segregated nanostructure of an MPL is revealed for the first time through the development of a customized, non-destructive procedure for monochromatic nano-scale X-ray computed tomography visualization. Utilizing this technique, it is discovered that PTFE is situated in conglomerated regions distributed randomly within connected domains of carbon particles; hence, it is concluded that PTFE acts as a binder for the carbon particles and provides structural support for the MPL. Exposed PTFE surfaces are also observed that will aid the desired hydrophobicity of the material. Additionally, the present approach uniquely enables phase segregated calculation of effective transport properties, as reported herein, which is particularly important for accurate estimation of electrical and thermal conductivity. Overall, the new imaging technique and associated findings may contribute to further performance improvements and cost reduction in support of fuel cell commercialization for clean energy applications.
Robust Non-Wetting PTFE Surfaces by Femtosecond Laser Machining
Liang, Fang; Lehr, Jorge; Danielczak, Lisa; Leask, Richard; Kietzig, Anne-Marie
2014-01-01
Nature shows many examples of surfaces with extraordinary wettability, which can often be associated with particular air-trapping surface patterns. Here, robust non-wetting surfaces have been created by femtosecond laser ablation of polytetrafluoroethylene (PTFE). The laser-created surface structure resembles a forest of entangled fibers, which support structural superhydrophobicity even when the surface chemistry is changed by gold coating. SEM analysis showed that the degree of entanglement of hairs and the depth of the forest pattern correlates positively with accumulated laser fluence and can thus be influenced by altering various laser process parameters. The resulting fibrous surfaces exhibit a tremendous decrease in wettability compared to smooth PTFE surfaces; droplets impacting the virgin or gold coated PTFE forest do not wet the surface but bounce off. Exploratory bioadhesion experiments showed that the surfaces are truly air-trapping and do not support cell adhesion. Therewith, the created surfaces successfully mimic biological surfaces such as insect wings with robust anti-wetting behavior and potential for antiadhesive applications. In addition, the fabrication can be carried out in one process step, and our results clearly show the insensitivity of the resulting non-wetting behavior to variations in the process parameters, both of which make it a strong candidate for industrial applications. PMID:25110862
Use of high L.E.T. radiation to improve adhesion of metals to polytetrafluoroethylene
NASA Technical Reports Server (NTRS)
Wheeler, D. R.; Pepper, S. V.
1982-01-01
MgK alpha X-rays (1254 eV) and 2 keV electrons irradiate the surface of polytetrafluoro ethylene (PTFE). The damage is confined to a few tenths of a micron below the surface, and the doses exceed 10 to the eight power rad. X-ray Photoelectron Spectroscopy (XPS) of the irradiated surfaces and mass spectroscopy of the gaseous products of irradiation indicate that the damaged layer is crosslinked or branched PTFE. After either type of irradiation, the surface has enhanced affinity for metals and a lower contact angle with hexadecane. Tape pull tests show that evaporated Ni and Au films adhere better to the irradiated surface. XPS shows the Ni interacts chemically with PTFE forming NiF2 and possibly NiC. However, the gold adhesion and contact angle results indicate that the interaction is, at least in part, chemically nonspecific. Decreased contact angles on FEP Teflon crystallized against gold were attributed to either the presence of a polar oxygen layer or increased physical forces due to greater density. In the case of irradiated PTFE, no oxygen on the surface was observed. The crosslinked structure might, however, have a greater density, thus accounting for the observed increase in adhesion and wettability.
Decontaminating materials used in ground water sampling devices: Organic contaminants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parker, L.V.; Ranney, T.A.
2000-12-31
In these studies, the efficiency of various decontamination protocols was tested on small pieces of materials commonly used in ground water sampling devices. Three materials, which ranged in ability to sorb organic solutes, were tested: stainless steel (SS), rigid polyvinyl chloride (PVC), and polytetrafluoroethylene (PTFE). The test pieces were exposed to two aqueous test solutions: One contained three volatile organic compounds (VOCs) and one nitroaromatic compound, and the other contained four pesticides. Also, three types of polymetic tubing were exposed to pesticide solutions. Generally, the contact times were 10 minutes and 24 hours for sorption and desorption. The contaminants weremore » removed from the nonpermeable SS and the less-sorptive rigid PVC test pieces simply by washing with a hot detergent solution and rinsing with hot water. Additional treatment was required for the PTFE test pieces exposed to the VOCs and for the low-density polyethylene (LDPE) tubing exposed to the pesticide test solution. Solvent rinsing did not improve removal of the three VOCs form the PTFE and only marginally improved removal of the residual pesticides from the LDPE. However, a hot water and detergent wash and rinse followed by oven drying at approximately 105 C was effective for removing the VOCs from the PTFE and substantially reduced pesticide contamination from the LDPE.« less
Cathode catalysts for primary phosphoric acid fuel cells
NASA Technical Reports Server (NTRS)
1981-01-01
Alkylation or carbon Vulcan XC-72, the support carbon, was shown to provide the most stable bond type for linking cobalt dehydrodibenzo tetraazannulene (CoTAA) to the surface of the carbon; this result is based on data obtained by cyclic voltammetry, pulse voltammetry and by release of 14C from bonded CoTAA. Half-cell tests at 100 C in 85% phosphoric acid showed that CoTAA bonded to the surface of carbon (Vulcan XC-72) via an alkylation procedure is a more active catalyst than is platinum based on a factor of two improvement in Tafel slope; dimeric CoTAA had catalytic activity equal to platinum. Half-cell tests also showed that bonded CoTAA catalysts do not suffer a loss in potential when air is used as a fuel rather than oxygen. Commercially available polytetrafluroethylene (PTFE) was shown to be unstable in the fuel cell environment with degradation occurring in 2000 hours or less. The PTFE was stressed at 200 C in concentrated phosphoric acid as well as electrochemically stressed in 150 C concentrated phosphoric acid; the surface chemistry of PTFE was observed to change significantly. Radiolabeled PTFE was prepared and used to verify that such chemical changes also occur in the primary fuel cell environment.
Amphiphobic Polytetrafluoroethylene Membranes for Efficient Organic Aerosol Removal.
Feng, Shasha; Zhong, Zhaoxiang; Zhang, Feng; Wang, Yong; Xing, Weihong
2016-04-06
Polytetrafluoroethylene (PTFE) membrane is an extensively used air filter, but its oleophilicity leads to severe fouling of the membrane surface due to organic aerosol deposition. Herein, we report the fabrication of a new amphiphobic 1H,1H,2H,2H-perfluorodecyl acrylate (PFDAE)-grafted ZnO@PTFE membrane with enhanced antifouling functionality and high removal efficiency. We use atomic-layer deposition (ALD) to uniformly coat a layer of nanosized ZnO particles onto porous PTFE matrix to increase surface area and then subsequently graft PFDAE with plasma. Consequently, the membrane surface showed both superhydrophobicity and oleophobicity with a water contact angle (WCA) and an oil contact angle (OCA) of 150° and 125°, respectively. The membrane air permeation rate of 513 (m(3) m(-2) h(-1) kPa(-1)) was lower than the pristine membrane rate of 550 (m(3) m(-2) h(-1) kPa(-1)), which indicates the surface modification slightly decreased the membrane air permeation. Significantly, the filtration resistance of this amphiphobic membrane to the oil aerosol system was much lower than the initial one. Moreover, the filter exhibited exceptional organic aerosol removal efficiencies that were greater than 99.5%. These results make the amphiphobic PTFE membranes very promising for organic aerosol-laden air-filtration applications.
Effect of Edmark Program on Reading Fluency in Third-Grade Students with Disabilities
ERIC Educational Resources Information Center
Meeks, Bryce T.; Martinez, James; Pienta, Rachel S.
2014-01-01
The purpose of this research study was to determine if the Edmark Reading Program increased reading fluency, attitudes, and engagement in third-grade students with disabilities (N = 7). Student fluency was measured using estimated oral reading fluency determined by the STAR reading assessment. A statistically significant difference was found…
Effects of Repeated Reading and Listening Passage Preview on Oral Reading Fluency
ERIC Educational Resources Information Center
Swain, Kristine D.; Leader-Janssen, Elizabeth M.; Conley, Perry
2017-01-01
This case study examined the effectiveness of three fluency interventions (i.e., repeated reading, audio listening passage preview and teacher modeled listening passage preview) with a fifth grade student struggling with fluency skills. When compared to baseline, each intervention increased oral reading fluency by the end of the 7 weeks of…
Liberating the Arts: Promoting IT Fluency through the Pedagogy of Digital Storytelling
ERIC Educational Resources Information Center
Warren, Kenneth Xavier, Jr.
2011-01-01
Fluency in information technology (IT Fluency) is a component of life-long learning necessary for a Liberal Arts student's post-graduate success in the global and digital economy. While challenging, promoting IT fluency at Liberal Arts colleges can be achieved through the integration of digital storytelling pedagogy in existing humanities…
Educational Factors and Experiences in English Language Learner Reading Fluency Development
ERIC Educational Resources Information Center
Weber, Christina J. T.
2013-01-01
Reading fluency has been an area of struggle for students. Certain populations of students, such as English language learners (ELLs), have struggled even more so, affecting their overall achievement. Interventions have been implemented and studied regarding the reading fluency of ELLs, yet reading fluency has continued to be problematic in this…
Speed Reading Courses and Their Effect on Reading Authentic Texts: A Preliminary Investigation
ERIC Educational Resources Information Center
Macalister, John
2010-01-01
Fluent reading is essential for successful comprehension. One dimension of reading fluency is reading rate, or reading speed. Because of the importance of reading fluency, fluency development activities should be incorporated into classroom practice. One activity that meets the fluency development conditions proposed by Nation (2007) is speed…
Fluency Idol: Using Pop Culture to Engage Students and Boost Fluency Skills
ERIC Educational Resources Information Center
Calo, Kristine M.; Woolard-Ferguson, Taylor; Koitz, Ellen
2013-01-01
This article shares an oral reading practice that develops children's fluency skills, with a particular emphasis on performance reading and prosody. The authors share their experiences with Fluency Idol! as a way to engage young children by tapping into pop culture. The practice emphasizes repeated readings, feedback, practice, and…
ERIC Educational Resources Information Center
Reber, Rolf; Greifeneder, Rainer
2017-01-01
Processing fluency--the experienced ease with which a mental operation is performed--has attracted little attention in educational psychology, despite its relevance. The present article reviews and integrates empirical evidence on processing fluency that is relevant to school education. Fluency is important, for instance, in learning,…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hyun, Hyeran; Choi, Sun Young, E-mail: medmath@hanmail.net; Kim, Kyung Ah
PurposeTo estimate the safety and efficacy of percutaneous ePTFE-covered biliary stent placement and the relationship between underlying liver function and stent patency in patients with malignant hilar obstruction.Materials and MethodsFrom March 2012 to June 2015, 41 patients [22 females, 19 males; mean age 69.8 (range 34–94) years] with malignant biliary obstruction underwent percutaneous biliary stent placement (31 patients with unilateral, 10 patients with bilateral side-by-side). Cumulative patient survival and stent patency rate curves were derived using the Kaplan–Meier method. A Cox model was used to explore the relationship between liver function and patient survival, and also biliary stent patency. Pearsonmore » correlation coefficient was used to analyze the relationship between patient survival and stent patency.ResultsTechnical success rate was 100 % and clinical success rate was 95 %. During follow-up, four complications occurred (two bilomas and two cases of acute cholecystitis) and were treated successfully with percutaneous drainage. No other complication occurred. Mean serum bilirubin level was 11.34 ± 7.35 mg/dL before drainage and 5.00 ± 4.83 mg/dL 2 weeks after stent placement. The median patent survival duration was 147 days (95 % CI, 69.6–224.4 days). The median stent patency duration was 101 days (95 % CI, 70.0–132.0 days). The cumulative stent patency rates at 1, 3, 6, and 12 months were 97, 57.6, 30.3, and 17.0 %, respectively. Child–Pugh score was correlated significantly with patient survival (P = 0.011) and stent patency (P = 0.007). MELD score was correlated significantly with stent patency (P = 0.044). There was a correlation between patient survival and stent patency (r = 0.778, P < 0.001).ConclusionPercutaneous placement of ePTFE-covered biliary stent was a safe and an effective method for malignant biliary obstruction. Underlying liver function seemed to be one of the important factors affecting patient survival and stent patency, and stent patency showed statistically significant correlation with patient survival.« less
Stevens, Elizabeth A.; Walker, Melodee A.; Vaughn, Sharon
2016-01-01
Fluent word reading is hypothesized to facilitate reading comprehension by improving automatic word reading, thus releasing a reader’s cognitive resources to focus on meaning. Many students with learning disabilities (LD) struggle to develop reading fluency, which affects reading comprehension. This synthesis extends Chard, Vaughn, and Tyler’s (2002) review, synthesizing fluency intervention research from 2001 to 2014. The search yielded 19 studies examining reading fluency and comprehension outcomes of reading fluency interventions for students with LD in kindergarten through 5th grade. Results showed repeated reading (RR), multicomponent interventions, and assisted reading with audiobooks produced gains in reading fluency and comprehension. Providing a model of fluent reading and performance feedback, using easier level text, setting a performance criterion, and practicing RR with peers also contributed to improved outcomes. Findings suggest that RR remains the most effective intervention for improving reading fluency for students with LD. Limitations include sample size, only three group design studies, and infrequent use of standardized measures. PMID:27067939
Stevens, Elizabeth A; Walker, Melodee A; Vaughn, Sharon
Fluent word reading is hypothesized to facilitate reading comprehension by improving automatic word reading, thus releasing a reader's cognitive resources to focus on meaning. Many students with learning disabilities (LD) struggle to develop reading fluency, which affects reading comprehension. This synthesis extends Chard, Vaughn, and Tyler's (2002) review, synthesizing fluency intervention research from 2001 to 2014. The search yielded 19 studies examining reading fluency and comprehension outcomes of reading fluency interventions for students with LD in kindergarten through 5th grade. Results showed repeated reading (RR), multicomponent interventions, and assisted reading with audiobooks produced gains in reading fluency and comprehension. Providing a model of fluent reading and performance feedback, using easier level text, setting a performance criterion, and practicing RR with peers also contributed to improved outcomes. Findings suggest that RR remains the most effective intervention for improving reading fluency for students with LD. Limitations include sample size, only three group design studies, and infrequent use of standardized measures.
Batty, Rachel; Francis, Andrew; Thomas, Neil; Hopwood, Malcolm; Ponsford, Jennie; Johnston, Lisa; Rossell, Susan
2015-06-30
Verbal fluency in patients with psychosis following traumatic brain injury (PFTBI) has been reported as comparable to healthy participants. This finding is counterintuitive given the prominent fluency impairments demonstrated post-traumatic brain injury (TBI) and in psychotic disorders, e.g. schizophrenia. We investigated phonemic (executive) fluency (3 letters: 'F' 'A' and 'S'), and semantic fluency (1 category: fruits and/or vegetables) in four matched groups; PFTBI (N=10), TBI (N=10), schizophrenia (N=23), and healthy controls (N=23). Words produced (minus perseverations and errors), and clustering and switching scores were compared for the two fluency types across the groups. The results confirmed that PFTBI patients do show impaired fluency, aligned with existing evidence in TBI and schizophrenia. PFTBI patients produced the least amount of words on the phonemic fluency ('A') trial and total score, and demonstrated reduced switching on both phonemic and semantic tasks. No significant differences in clustering performance were found. Importantly, the pattern of results suggested that PFTBI patients share deficits with their brain-injured (primarily executive), and psychotic (executive and semantic), counterparts, and that these are exacerbated by their dual-diagnosis. These findings add to a very limited literature by providing novel evidence of the nature of fluency impairments in dually-diagnosed PFTBI. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
What do people who stutter want--fluency or freedom?
Venkatagiri, H S
2009-04-01
In this study, the author examined the following questions: What proportion of adult persons who stutter (PWS) choose fluency and what proportion choose to be free from a need to be fluent in managing their stuttering? What demographic and stuttering-related variables influence their choice, and how consistent are they in their choice? A survey instrument administered over the Internet was used to collect the data. Overall, 8% more of the 216 respondents opted for fluency than freedom. A larger proportion of male PWS and PWS under the age of 30 years preferred fluency. Neither nationality nor language background influenced their preference. Those who received no therapy overwhelmingly chose fluency, and a slight majority of those with fewer than 5 years of therapy preferred fluency. Those with more than 5 years of therapy were evenly divided between the 2 choices. Those who preferred freedom were more consistent in their responses across items than were those who opted for fluency. Based on the consistency of responses, 20% and 23% of the sample decisively opted for fluency and freedom, respectively, and 34% in the fluency group and 23% in the freedom group were ambivalent. A majority of PWS appear to benefit from flexible treatment programs with cafeteria-style choices.
Thompson, Valerie A; Turner, Jamie A Prowse; Pennycook, Gordon; Ball, Linden J; Brack, Hannah; Ophir, Yael; Ackerman, Rakefet
2013-08-01
Although widely studied in other domains, relatively little is known about the metacognitive processes that monitor and control behaviour during reasoning and decision-making. In this paper, we examined the conditions under which two fluency cues are used to monitor initial reasoning: answer fluency, or the speed with which the initial, intuitive answer is produced (Thompson, Prowse Turner, & Pennycook, 2011), and perceptual fluency, or the ease with which problems can be read (Alter, Oppenheimer, Epley, & Eyre, 2007). The first two experiments demonstrated that answer fluency reliably predicted Feeling of Rightness (FOR) judgments to conditional inferences and base rate problems, which subsequently predicted the amount of deliberate processing as measured by thinking time and answer changes; answer fluency also predicted retrospective confidence judgments (Experiment 3b). Moreover, the effect of answer fluency on reasoning was independent from the effect of perceptual fluency, establishing that these are empirically independent constructs. In five experiments with a variety of reasoning problems similar to those of Alter et al. (2007), we found no effect of perceptual fluency on FOR, retrospective confidence or accuracy; however, we did observe that participants spent more time thinking about hard to read stimuli, although this additional time did not result in answer changes. In our final two experiments, we found that perceptual disfluency increased accuracy on the CRT (Frederick, 2005), but only amongst participants of high cognitive ability. As Alter et al.'s samples were gathered from prestigious universities, collectively, the data to this point suggest that perceptual fluency prompts additional processing in general, but this processing may results in higher accuracy only for the most cognitively able. Crown Copyright © 2012. Published by Elsevier B.V. All rights reserved.
The differing roles of the frontal cortex in fluency tests
Shallice, Tim; Bozzali, Marco; Cipolotti, Lisa
2012-01-01
Fluency tasks have been widely used to tap the voluntary generation of responses. The anatomical correlates of fluency tasks and their sensitivity and specificity have been hotly debated. However, investigation of the cognitive processes involved in voluntary generation of responses and whether generation is supported by a common, general process (e.g. fluid intelligence) or specific cognitive processes underpinned by particular frontal regions has rarely been addressed. This study investigates a range of verbal and non-verbal fluency tasks in patients with unselected focal frontal (n = 47) and posterior (n = 20) lesions. Patients and controls (n = 35) matched for education, age and sex were administered fluency tasks including word (phonemic/semantic), design, gesture and ideational fluency as well as background cognitive tests. Lesions were analysed by standard anterior/posterior and left/right frontal subdivisions as well as a finer-grained frontal localization method. Thus, patients with right and left lateral lesions were compared to patients with superior medial lesions. The results show that all eight fluency tasks are sensitive to frontal lobe damage although only the phonemic word and design fluency tasks were specific to the frontal region. Superior medial patients were the only group to be impaired on all eight fluency tasks, relative to controls, consistent with an energization deficit. The most marked fluency deficits for lateral patients were along material specific lines (i.e. left—phonemic and right—design). Phonemic word fluency that requires greater selection was most severely impaired following left inferior frontal damage. Overall, our results support the notion that frontal functions comprise a set of specialized cognitive processes, supported by distinct frontal regions. PMID:22669082
Fishman, Keera N; Ashbaugh, Andrea R; Lanctôt, Krista L; Cayley, Megan L; Herrmann, Nathan; Murray, Brian J; Sicard, Michelle; Lien, Karen; Sahlas, Demetrios J; Swartz, Richard H
2018-06-01
This study examined the relationship between apathy and cognition in patients with cerebrovascular disease. Apathy may result from damage to frontal subcortical circuits causing dysexecutive syndromes, but apathy is also related to depression. We assessed the ability of apathy to predict phonemic fluency and semantic fluency performance after controlling for depressive symptoms in 282 individuals with stroke and/or transient ischemic attack. Participants (N = 282) completed the Phonemic Fluency Test, Semantic Fluency Test, Center for Epidemiologic Studies Depression Scale, and Apathy Evaluation Scale. A cross-sectional correlational design was utilized. Using hierarchical linear regressions, apathy scores significantly predicted semantic fluency performance (β = -.159, p = .020), but not phonemic fluency performance (β = -.112, p = .129) after scaling scores by age and years of education and controlling for depressive symptoms. Depressive symptoms entered into the first step of both hierarchical linear regressions did not predict semantic fluency (β = -.035, p = .554) or phonemic fluency (β = -.081, p = .173). Apathy and depressive symptoms were moderately correlated, r(280) = .58, p < .001. The results of this study are consistent with research supporting a differentiation between phonemic and semantic fluency tasks, whereby phonemic fluency tasks primarily involve frontal regions, and semantic fluency tasks involve recruitment of more extended networks. The results also highlight a distinction between apathy and depressive symptoms and suggest that apathy may be a more reliable predictor of cognitive deficits than measures of mood in individuals with cerebrovascular disease. Apathy may also be more related to cognition due to overlapping motivational and cognitive frontal subcortical circuitry. Future research should explore whether treatments for apathy could be a novel target for improving cognitive outcomes after stroke.
Experimental Studies of Phase Equilibria of Meteorites and Planetary Bodies
NASA Technical Reports Server (NTRS)
Stolper, Edward M.
2005-01-01
The primary theme of this project was the application of experimental petrology and geochemistry to a variety of problems in meteoritics and planetary geology. The studies were designed to help develop constraints on the histories of primitive meteorites and their components, the environments in which they formed and evolved, and to understand quantitatively the processes involved in the evolution of igneous rocks on the earth and other planetary bodies. We undertook several projects relating to the origin of CAIs and chondrules. Systematics in the thermodynamic properties of CAI-like liquids were investigated and used to elucidate speciation of multi-valent cations and sulfide capacity of silicate melts and to constrain redox conditions and the vapor pressures of volatile species over molten chondrules. We experimentally determined vanadium speciation in meteoritic pyroxenes and in pyroxenes crystallized from CAI-like melts under very reducing conditions. We also found that bulk oxygen isotope compositions of chondrules in the moderately unequilibrated LL chondrites are related to the relative timing of plagioclase crystallization. We completed an experimental study on the vaporization of beta-SiC and SiO2 (glass or cristobalite) in reducing gases and established the conditions under which these presolar grains could have survived in the solar nebula. We expanded our technique for determining the thermodynamic properties of minerals and liquids to iron-bearing systems. We determined activity-composition relationships in Pt-Fe, Pt-Cr and Pt-Fe-Cr alloys. Results were used to determine the thermodynamic properties of chromite-picrochromite spinels including the free energy of formation of end-member FeCr2O4. We also established a new approach for evaluating Pt-Fe saturation experiments. We calculated the T-fO2 relationships in equilibrated ordinary chondrites and thereby constrained the conditions of metamorphism in their parent bodies.
Kidd, Kameha R; Dal Ponte, Donny B; Kellar, Robert S; Williams, Stuart K
2002-03-15
End product application is an important consideration when evaluating a material in an in vivo setting (Didisheim, Cardiovasc Pathol 1993;2:1S-2S). Small animal models allow high through-put evaluation of biocompatability. Previous preclinical evaluations have often used a rat subcutaneous model for the characterization of material-tissue interaction. Recent advances in genetic manipulation have provided mouse models with selective expression of a wide range of critical proteins. The rat model does not have many of the resources (i.e., knockouts, SCID, nude) that are present in mouse strains. The availability of these mice provides a resource to delineate the mechanisms regulating the healing associated with implants. However, before the mouse models can be used, they must be validated with respect to their ability to accurately assess tissue responses to materials. In this study the tissue responses after the implantation of expanded polytetrafluoroethylene (ePTFE) were compared between rat and mouse. Discs of ePTFE (30-microm internodal distance) were implanted in subcutaneous and epididymal fat tissue of rats (Sprague-Dawley) and mice (129-SVJ). After 5 weeks the samples were removed and evaluated for vascular density, inflammation, and fibrous encapsulation. No difference in the vessel density was observed within the peri-implant subcutaneous and adipose tissue or within the porous material. However, a significant difference was found in the number of activated macrophages and giant cells between these two species. Implants in the rat exhibited greater numbers of activated inflammatory cells in the peri-implant tissue. The data indicate that the mouse and rat provide a comparable model for evaluating angiogenesis and neovascularization associated with synthetic porous implants. Copyright 2001 John Wiley & Sons, Inc. J Biomed Mater Res 59: 682-689, 2002
Measurement of the absolute reflectance of polytetrafluoroethylene (PTFE) immersed in liquid xenon
NASA Astrophysics Data System (ADS)
Neves, F.; Lindote, A.; Morozov, A.; Solovov, V.; Silva, C.; Bras, P.; Rodrigues, J. P.; Lopes, M. I.
2017-01-01
The performance of a detector using liquid xenon (LXe) as a scintillator is strongly dependent on the collection efficiency for xenon scintillation light, which in turn is critically dependent on the reflectance of the surfaces that surround the active volume. To improve the light collection in such detectors the active volume is usually surrounded by polytetrafluoroethylene (PTFE) reflector panels, used due to its very high reflectance—even at the short wavelength of scintillation light of LXe (peaked at 178 nm). In this work, which contributed to the overall R&D effort towards the LUX-ZEPLIN (LZ) experiment, we present experimental results for the absolute reflectance measurements of three different PTFE samples (including the material used in the LUX detector) immersed in LXe for its scintillation light. The obtained results show that very high bi-hemispherical reflectance values (>= 97%) can be achieved, enabling very low energy thresholds in liquid xenon scintillator-based detectors.
NASA Astrophysics Data System (ADS)
Reznickova, Alena; Kvitek, Ondrej; Kolarova, Katerina; Smejkalova, Zuzana; Svorcik, Vaclav
2017-06-01
The aim of this article is to investigate the effect of the interface between plasma activated, gold and carbon coated poly(tetrafluoroethylene) (PTFE) on in vitro adhesion and spreading of mouse fibroblasts (L929). Surface properties of pristine and modified PTFE were studied by several experimental techniques. The thickness of a deposited gold film is an increasing function of the sputtering time, conversely thickness of carbon layer decreases with increasing distance between carbon source and the substrate. Because all the used surface modification techniques take place in inert Ar plasma, oxidized degradation products are formed on the PTFE surface, which affects wettability of the polymer surface. Cytocompatibility tests indicate that on samples with Au/C interface, the cells accumulate on the part of sample with evaporated carbon. Number of L929 cells proliferated on the studied samples is comparable to tissue culture polystyrene standard.
Müller, Christine; Lüders, Anne; Hoth-Hannig, Wiebke; Hannig, Matthias; Ziegler, Christiane
2010-03-16
The adsorption of bovine serum albumin (BSA) on surfaces of dental enamel and of dental materials was investigated by scanning force spectroscopy. This method provides adhesion forces which can be measured as a function of contact time between protein and surface, pH, wettability, and isoelectric point of the surface. Whereas the chosen ceramic and composite materials resemble very well the adhesion on natural enamel, a much stronger adhesion was found for the more hydrophobic surfaces, that is, gold, titanium, poly(methyl methacrylate) (PMMA), and poly(tetrafluoroethylene) (PTFE). On hydrophilic surfaces, adhesion is mainly influenced by the electrostatic forces between protein and surface. However, the conformational change of BSA at pH values above pH 8 has to be taken into account. On the very hydrophobic PTFE surface, the special interface structure between PTFE and water plays an important role which governs BSA adhesion.
Replacement bearing for Rocketdyne SSME HPOTPs using alternate self-lubricating retainer materials
NASA Technical Reports Server (NTRS)
Gleeson, J.; Dufrane, K.; Kannel, J.
1992-01-01
Research was conducted to develop replacement bearings for the Rocketdyne Space Shuttle main engine (SSME) high pressure oxidizer turbopumps (HPOTPs). The replacement bearings consisted of standard balls and races with a special Battelle Self-Lubricating Insert Configuration (BASIC) retainer. The BASIC retainer consists of a phosphor bronze housing with inserts consisting of a polytetrafluoretheylene (PTFE) and bronze compound. The PTFE contacts the balls and the land guiding surface on the outer race. A PTFE transfer film is formed on balls and races, which lubricates the critical interfaces. The BASIC retainer is a one-to-one replacement for the current Armalon retainer, but has superior lubricating properties and is stronger over the broad temperature range anticipated for the HPOTP bearings. As a part of the project 40 sets of balls and races (two sizes) and 52 BASIC retainers were shipped to NASA/MSFC.
Constitutive modeling of the dynamic-tensile-extrusion test of PTFE
NASA Astrophysics Data System (ADS)
Resnyansky, A. D.; Brown, E. N.; Trujillo, C. P.; Gray, G. T.
2017-01-01
Use of polymers in defense, aerospace and industrial applications under extreme loading conditions makes prediction of the behavior of these materials very important. Crucial to this is knowledge of the physical damage response in association with phase transformations during loading and the ability to predict this via multi-phase simulation accounting for thermodynamical non-equilibrium and strain rate sensitivity. The current work analyzes Dynamic-Tensile-Extrusion (Dyn-Ten-Ext) experiments on polytetrafluoroethylene (PTFE). In particular, the phase transition during loading and subsequent tension are analyzed using a two-phase rate sensitive material model implemented in the CTH hydrocode. The calculations are compared with experimental high-speed photography. Deformation patterns and their link with changing loading modes are analyzed numerically and correlated to the test observations. It is concluded that the phase transformation is not as critical to the response of PTFE under Dyn-Ten-Ext loading as it is during the Taylor rod impact testing.
Simulation of Particle Size Effect on Dynamic Properties and Fracture of PTFE-W-Al Composites
NASA Astrophysics Data System (ADS)
Herbold, Eric; Cai, Jing; Benson, David; Nesterenko, Vitali
2007-06-01
Recent investigations of the dynamic compressive strength of cold isostatically pressed (CIP) composites of polytetrafluoroethylene (PTFE), tungsten and aluminum powders show significant differences depending on the size of metallic particles. PTFE and aluminum mixtures are known to be energetic under dynamic and thermal loading. The addition of tungsten increases density and overall strength of the sample. Multi-material Eulerian and arbitrary Lagrangian-Eulerian methods were used for the investigation due to the complexity of the microstructure, relatively large deformations and the ability to handle the formation of free surfaces in a natural manner. The calculations indicate that the observed dependence of sample strength on particle size is due to the formation of force chains under dynamic loading in samples with small particle sizes even at larger porosity in comparison with samples with large grain size and larger density.
ERIC Educational Resources Information Center
Turner, Franklin Dickerson
2012-01-01
The author examined the effectiveness of 2 fluency-oriented reading programs on improving reading fluency for an ethnically diverse sample of second-grade students. The first approach is Fluency-Oriented Reading Instruction (S. A. Stahl & K. Heubach, 2005), which incorporates the repeated reading of a grade-level text over the course of an…
Mirror Asymmetry of Category and Letter Fluency in Traumatic Brain Injury and Alzheimer's Patients
ERIC Educational Resources Information Center
Capitani, Erminio; Rosci, Chiara; Saetti, Maria Cristina; Laiacona, Marcella
2009-01-01
In this study we contrasted the Category fluency and Letter fluency performance of 198 normal subjects, 57 Alzheimer's patients and 57 patients affected by traumatic brain injury (TBI). The aim was to check whether, besides the prevalence of Category fluency deficit often reported among Alzheimer's patients, the TBI group presented the opposite…
Reversing the Truth Effect: Learning the Interpretation of Processing Fluency in Judgments of Truth
ERIC Educational Resources Information Center
Unkelbach, Christian
2007-01-01
Repeated statements receive higher truth ratings than new statements. Given that repetition leads to greater experienced processing fluency, the author proposes that fluency is used in truth judgments according to its ecological validity. Thus, the truth effect occurs because people learn that fluency and truth tend to be positively correlated.…
Attentional Regulation in Young Twins with Probable Stuttering, High Nonfluency, and Typical Fluency
ERIC Educational Resources Information Center
Felsenfeld, Susan; van Beljsterveldt, Catharina Eugenie Maria; Boomsma, Dorret Irene
2010-01-01
Purpose: Using a sample of 20,445 Dutch twins, this study examined the relationship between speech fluency and attentional regulation in children. A secondary objective was to identify etiological overlap between nonfluency and poor attention using fluency-discordant twin pairs. Method: Three fluency groups were created at age 5 using a parent…
How Fast Can We Read in the Mind? Developmental Trajectories of Silent Reading Fluency
ERIC Educational Resources Information Center
Ciuffo, Massimo; Myers, Jane; Ingrassia, Massimo; Milanese, Antonio; Venuti, Maria; Alquino, Ausilia; Baradello, Alice; Stella, Giacomo; Gagliano, Antonella
2017-01-01
The silent reading fluency is not an observable behaviour and, therefore, its evaluation is perceived as more challenging and less reliable than oral reading fluency. The present research is aimed to measure the silent reading speed in a sample of proficient students, assessed by an original silent reading fluency task, based on behavioural…
The Evaluation of Second Language Fluency and Foreign Accent
ERIC Educational Resources Information Center
Wu, Chen-Huei
2011-01-01
What is second language fluency? What is a foreign accent? Is it possible for an adult second language learner to speak fluently with a heavy accent or vice versa? What factors contribute to the perception of fluency and a foreign accent? What acoustic attributes correlate with the perception of fluency and a foreign accent? To answer these…
Native Speakers' Perceptions of Fluency and Accent in L2 Speech
ERIC Educational Resources Information Center
Pinget, Anne-France; Bosker, Hans Rutger; Quené, Hugo; de Jong, Nivja H.
2014-01-01
Oral fluency and foreign accent distinguish L2 from L1 speech production. In language testing practices, both fluency and accent are usually assessed by raters. This study investigates what exactly native raters of fluency and accent take into account when judging L2. Our aim is to explore the relationship between objectively measured temporal,…
A Longitudinal Study of Novice-Level Changes in Fluency and Accuracy in Student Monologues
ERIC Educational Resources Information Center
Long, Robert W., III.
2012-01-01
Detailed research concerning the issue fluency, specifically relating to pauses, mean length runs, and fluency rates in Japanese EFL learners, is limited. Furthermore, the issue of tracking fluency gains has often been ignored, misunderstood or minimized in EFL educational research. The present study, which is based on six monologues conducted…
Analysis of brief language tests in the detection of cognitive decline and dementia
Radanovic, Marcia; Carthery-Goulart, Maria Teresa; Charchat-Fichman, Helenice; Herrera Jr., Emílio; Lima, Edson Erasmo Pereira; Smid, Jerusa; Porto, Cláudia Sellitto; Nitrini, Ricardo
2007-01-01
Lexical access difficulties are frequent in normal aging and initial stages of dementia.Verbal fluency tests are valuable to detect cognitive decline, evidencing lexico-semantic and executive dysfunction. Objectives To establish which language tests can contribute in detecting dementia and to verify schooling influence on subject performance. Method 74 subjects: 33 controls, 17 Clinical Dementia Rating (CDR) 0.5 and 24 (Brief Cognitive Battery - BCB e Boston Naming Test - BNT) 1 were compared in tests of semantic verbal fluency (animal and fruit), picture naming (BCB and BNT) and the language items of Mini Mental State Examination (MMSE). Results There were significant differences between the control group and both CDR 0.5 and CDR 1 in all tests. Cut-off scores were: 11 and 10 for animal fluency, 8 for fruit fluency (in both), 8 and 9 for BCB naming. The CDR 0.5 group performed better than the CDR 1 group only in animal fluency. Stepwise multiple regression revealed fruit fluency, animal fluency and BCB naming as the best discriminators between patients and controls (specificity: 93.8%; sensitivity: 91.3%). In controls, comparison between illiterates and literates evidenced schooling influence in all tests, except for fruit fluency and BCB naming. In patients with dementia, only fruit fluency was uninfluenced by schooling. Conclusion The combination of verbal fluency tests in two semantic categories along with a simple picture naming test is highly sensitive in detecting cognitive decline. Comparison between literate and illiterate subjects shows a lesser degree of influence of schooling on the selected tests, thus improving discrimination between low performance and incipient cognitive decline. PMID:29213366
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yan, Yushan
In this work, multiple polymer backbones were screened for oxidation resistance and multiple chemistries were explored for tethering tris(2,4,6-trimethylphenyl)phosphonium (9MeTTP +) to the selected polymer backbones. A new tethering strategy through brominated 9MeTTP+ cation was developed and used to obtain the desired 9MeTTP +-functionalized polysulfone (PSf) and hexafluoro polybenzimidazole (F 6PBI) polymer. The crosslinked 9MeTTP+-functionalized hexafluoro polybenzimidazole (9MeTTP-F 6PBI) polymer demonstrated excellent oxidation stability that met the go-no-go milestone of the first year. However, large-scale bromination inevitably involved multi-bromination products, which led to polymer crosslinking in the next tethering. A new synthesis strategy with diiodobutane as linker was developed tomore » overcome the crosslinking problem. The prepared 9MeTTP +-F 6PBI membrane without crosslinking showed only 3.58% water uptake and less than 1 mS/cm OH - conductivity in water at 20°C, possibly due to the hydrophobic 9MeTTP + cation. In order to improve the conductivity, hydrophilic tris(2,4,6-trimethoxylphenyl)phosphonium (9MeOTTP+) cation was tethered to an F 6PBI backbone, and a 9MeOTTP +-F 6PBI PTFE reinforced membrane was prepared with 17.4% water uptake to increase the mechanical strength and durability in cerium (IV) solution. A 9MeOTTP+-F 6PBI PTFE reinforced membrane had less than 20% conductivity loss during an accelerated stability test in 0.5 M cerium (IV) and 1.3 M HClO 4 at 55°C for 100 hours. Moreover, a 9MeOTTP +-F 6PBI PTFE reinforced membrane had more than double the lifetime of commercial FAS-30 and FAB-PK-130 AEMs during an accelerated stability test in 0.5 M cerium (IV) and 1.3 M HClO 4 at 55°C. Low area specific resistance (ASR) of a 9MeOTTP +-F 6PBI PTFE reinforced membrane in the sulfuric acid system was also achieved due to the high acid doping ability of the polymer structure. The cationic 9MeOTTP +-F 6PBI PTFE reinforced membrane shows a cerium (IV) permeability that is 27-fold lower than that of Nafion 212. Excellent voltage and energy efficiencies with a 9MeOTTP +-F 6PBI PTFE reinforced membrane were demonstrated in an all-vanadium redox flow battery (VRFB).« less
The Effects of Word Walls and Word Wall Activities on the Reading Fluency of First Grade Students
ERIC Educational Resources Information Center
Jasmine, Joanne; Schiesl, Pamela
2009-01-01
Reading fluency is the ability to read orally with speed and efficiency, including word recognition, decoding, and comprehension (Chard & Pikulski, 2005). Able readers achieve fluency as they recognize words with speed and build upon them to aid in comprehension (Pumfrey & Elliott, 1990). One way to help students achieve fluency is through the use…
Construct Validity of Fluency and Implications for the Factorial Structure of Memory
ERIC Educational Resources Information Center
Jewsbury, Paul A.; Bowden, Stephen C.
2017-01-01
Fluency is an important construct in clinical assessment and in cognitive taxonomies. In the Cattell-Horn-Carroll (CHC) model, Fluency is represented by several narrow factors that form a subset of the long-term memory encoding and retrieval (Glr) broad factor. The CHC broad classification of Fluency was evaluated in five data sets, and the CHC…
The Relationship between L1 Fluency and L2 Fluency Development
ERIC Educational Resources Information Center
Derwing, Tracey M.; Munro, Murray J.; Thomson, Ronald I.; Rossiter, Marian J.
2009-01-01
A fundamental question in the study of second language (L2) fluency is the extent to which temporal characteristics of speakers' first language (L1) productions predict the same characteristics in the L2. A close relationship between a speaker's L1 and L2 temporal characteristics would suggest that fluency is governed by an underlying trait. This…
ERIC Educational Resources Information Center
Crockett, Lee; Jukes, Ian; Churches, Andrew
2011-01-01
Educating students to traditional literacy standards is no longer enough. If students are to thrive in their academic and 21st century careers, then independent and creative thinking hold the highest currency. The authors explain in detail how to add these new components of literacy: (1) Solution Fluency; (2) Information Fluency; (3) Creativity…
ERIC Educational Resources Information Center
Begeny, John C.; Levy, Rebecca A.; Field, Stacey A.
2018-01-01
Reading fluency is necessary for reading comprehension, but approximately 40% of U.S. fourth-grade students have inadequate reading fluency skills. Because small-group (SG) instruction is often used as a first line of intervention for struggling readers, SG instruction targeting deficiencies in text reading fluency ought to be part of every…
ERIC Educational Resources Information Center
Mellard, Daryl F.; Anthony, Jason L.; Woods, Kari L.
2012-01-01
This study extends the literature on the component skills involved in oral reading fluency. Dominance analysis was applied to assess the relative importance of seven reading-related component skills in the prediction of the oral reading fluency of 272 adult literacy learners. The best predictors of oral reading fluency when text difficulty was…
Apathy and Reduced Speed of Processing Underlie Decline in Verbal Fluency following DBS.
Foley, Jennifer A; Foltynie, Tom; Zrinzo, Ludvic; Hyam, Jonathan A; Limousin, Patricia; Cipolotti, Lisa
2017-01-01
Objective . Reduced verbal fluency is a strikingly uniform finding following deep brain stimulation (DBS) for Parkinson's disease (PD). The precise cognitive mechanism underlying this reduction remains unclear, but theories have suggested reduced motivation, linguistic skill, and/or executive function. It is of note, however, that previous reports have failed to consider the potential role of any changes in speed of processing. Thus, the aim of this study was to examine verbal fluency changes with a particular focus on the role of cognitive speed. Method . In this study, 28 patients with PD completed measures of verbal fluency, motivation, language, executive functioning, and speed of processing, before and after DBS. Results . As expected, there was a marked decline in verbal fluency but also in a timed test of executive functions and two measures of speed of processing. Verbal fluency decline was associated with markers of linguistic and executive functioning, but not after speed of processing was statistically controlled for. In contrast, greater decline in verbal fluency was associated with higher levels of apathy at baseline, which was not associated with changes in cognitive speed. Discussion . Reduced generativity and processing speed may account for the marked reduction in verbal fluency commonly observed following DBS.
Papadopoulos, Timothy C.; Spanoudis, George C.; Georgiou, George K.
2016-01-01
We examined the prominent theoretical explanations of the RAN-reading relationship in a relatively transparent language (Greek) in a sample of children (n = 286) followed from Grade 1 to Grade 2. Specifically, we tested the fit of eight different models, as defined by the type of reading performance predicted (oral vs. silent word reading fluency), the type of RAN tasks (non-alphanumeric vs. alphanumeric), and the RAN effects (direct vs. indirect). Working memory, attention, processing speed, and motor skills were used as “common cause” variables predicting both RAN and reading fluency and phonological awareness and orthographic processing were used as mediators of RAN's effects on reading fluency. The findings of both concurrent and longitudinal analyses indicated that RAN is a unique predictor of oral reading fluency, but not silent reading fluency. Using alphanumeric or non-alphanumeric RAN did not particularly affect the RAN-reading relationship. Both phonological awareness and orthographic processing partly mediated RAN's effects on reading fluency. Theoretical implications of these findings are discussed. PMID:27605918
Specialty Board on Fluency Disorders
... 54136 Site Map About Us Find a Specialist Consumers CE Home Contact © 2016 American Board of Fluency and Fluency Disorders. All rights reserved. Membership Software Powered by YourMembership :: Legal
Personality traits prospectively predict verbal fluency in a lifespan sample.
Sutin, Angelina R; Terracciano, Antonio; Kitner-Triolo, Melissa H; Uda, Manuela; Schlessinger, David; Zonderman, Alan B
2011-12-01
In a community-dwelling sample (N = 4,790; age range 14-94), we examined whether personality traits prospectively predicted performance on a verbal fluency task. Open, extraverted, and emotionally stable participants had better verbal fluency. At the facet level, dispositionally happy and self-disciplined participants retrieved more words; those prone to anxiety and depression and those who were deliberative retrieved fewer words. Education moderated the association between conscientiousness and fluency such that participants with lower education performed better on the fluency task if they were also conscientious. Age was not a moderator at the domain level, indicating that the personality-fluency associations were consistent across the life span. A disposition toward emotional vulnerability and being less open, less happy, and undisciplined may be detrimental to cognitive performance.
Personality Traits Prospectively Predict Verbal Fluency in a Lifespan Sample
Sutin, Angelina R.; Terracciano, Antonio; Kitner-Triolo, Melissa H.; Uda, Manuela; Schlessinger, David; Zonderman, Alan B.
2011-01-01
In a community-dwelling sample (N=4,790; age range 14–94), we examined whether personality traits prospectively predicted performance on a verbal fluency task. Open, extraverted, and emotionally stable participants had better verbal fluency. At the facet level, dispositionally happy and self-disciplined participants retrieved more words; those prone to anxiety and depression and those who were deliberative retrieved fewer words. Education moderated the association between Conscientiousness and fluency such that participants with lower education performed better on the fluency task if they were also conscientious. Age was not a moderator at the domain level, indicating that the personality-fluency associations were consistent across the lifespan. A disposition towards emotional vulnerability and being less open, less happy, and undisciplined may be detrimental to cognitive performance. PMID:21707179
Ion beam sputter etching and deposition of fluoropolymers
NASA Technical Reports Server (NTRS)
Banks, B. A.; Sovey, J. S.; Miller, T. B.; Crandall, K. S.
1978-01-01
Fluoropolymer etching and deposition techniques including thermal evaporation, RF sputtering, plasma polymerization, and ion beam sputtering are reviewed. Etching and deposition mechanism and material characteristics are discussed. Ion beam sputter etch rates for polytetrafluoroethylene (PTFE) were determined as a function of ion energy, current density and ion beam power density. Peel strengths were measured for epoxy bonds to various ion beam sputtered fluoropolymers. Coefficients of static and dynamic friction were measured for fluoropolymers deposited from ion bombarded PTFE.
Mizuguchi, Hitoshi; Matsuda, Yuki; Mori, Takehito; Uehara, Atsushi; Ishikawa, Yuta; Endo, Masatoshi; Shida, Junichi
2008-02-01
A new visual colorimetry for trace antimony(V) based on ion-pair solid-phase extraction to a PTFE-type membrane filter with bis[2-(5-chloro-2-pyridylazo)-5-diethylaminophenolato]cobalt(III) ion ([Co(5-Cl-PADAP)(2)](+)) has been developed. Experiments showed that hexachloroantimonate(V) ion (SbCl(6)(-)) was adsorbed with [Co(5-Cl-PADAP)(2)](+) to the front surface of the PTFE filter. The adsorption of antimony(V) ion was promoted by the addition of lithium chloride as a source of chloride ion. The excess reagent of [Co(5-Cl-PADAP)(2)](+) was eluted by rinsing with a 10 wt% methanol aqueous solution. In this case, the slow rate of the hydrolysis reaction of SbCl(6)(-) and the difference of the hydrophobicity of the ion pairs were important for adsorption and separation with a PTFE-type membrane filter. The antimony(V) concentration was determined through a visual comparison with a standard series. The visual detection limit was 0.10 microg. The calibration curve assessed with the reflection spectrometric responses at 580 nm was linear in the concentration range of 0.10 - 1.2 microg (r = 0.996). The proposed method has been applied to the determination of sub-microgram levels of antimony(V) ion in water samples.
Kim, Hwa-Min; Litao, Yao; Kim, Bonghwan
2015-11-01
We have developed a surface texturing process for pyramidal surface features along with an indium tin oxide (ITO) coating process to fabricate super-hydrophilic conductive surfaces. The contact angle of a water droplet was less than 5 degrees, which means that an extremely high wettability is achievable on super-hydrophilic surfaces. We have also fabricated a super-hydrophobic conductive surface using an additional coating of polytetrafluoroethylene (PTFE) on the ITO layer coated on the textured Si surface; the ITO and PTFE films were deposited by using a conventional sputtering method. We found that a super-hydrophilic conductive surface is produced by ITO coated on the pyramidal Si surface (ITO/Si), with contact angles of approximately 0 degrees and a resistivity of 3 x 10(-4) Ω x cm. These values are highly dependent on the substrate temperature during the sputtering process. We also found that the super-hydrophobic conductive surface produced by the additional coating of PTFE on the pyramidal Si surface with an ITO layer (PTFE/ITO/Si) has a contact angle of almost 160 degrees and a resistivity of 3 x 10(-4) Ω x cm, with a reflectance lower than 9%. Therefore, these processes can be used to fabricate multifunctional features of ITO films for switchable super-hydrophilic and super-hydrophobic surfaces.
An, Alicia Kyoungjin; Guo, Jiaxin; Jeong, Sanghyun; Lee, Eui-Jong; Tabatabai, S Assiyeh Alizadeh; Leiknes, TorOve
2016-10-15
This study investigated the applicability of membrane distillation (MD) to treat dyeing wastewater discharged by the textile industry. Four different dyes containing methylene blue (MB), crystal violet (CV), acid red 18 (AR18), and acid yellow 36 (AY36) were tested. Two types of hydrophobic membranes made of polytetrafluoroethylene (PTFE) and polyvinylidene fluoride (PVDF) were used. The membranes were characterized by testing against each dye (foulant-foulant) and the membrane-dye (membrane-foulant) interfacial interactions and their mechanisms were identified. The MD membranes possessed negative charges, which facilitated the treatment of acid and azo dyes of the same charge and showed higher fluxes. In addition, PTFE membrane reduced the wettability with higher hydrophobicity of the membrane surface. The PTFE membrane evidenced especially its resistant to dye absorption, as its strong negative charge and chemical structure caused a flake-like (loose) dye-dye structure to form on the membrane surface rather than in the membrane pores. This also enabled the recovery of flux and membrane properties by water flushing (WF), thereby direct-contact MD with PTFE membrane treating 100 mg/L of dye mixtures showed stable flux and superior color removal during five days operation. Thus, MD shows a potential for stable long-term operation in conjunction with a simple membrane cleaning process, and its suitability in dyeing wastewater treatment. Copyright © 2016 Elsevier Ltd. All rights reserved.
On the surface trapping parameters of polytetrafluoroethylene block
NASA Astrophysics Data System (ADS)
Zhang, Guan-Jun; Yang, Kai; Zhao, Wen-Bin; Yan, Zhang
2006-12-01
Surface flashover phenomena under high electric field are closely related to the surface characteristics of a solid insulating material between energized electrodes. Based on measuring the surface potential decaying curve of polytetrafluoroethylene (PTFE) block charged by a needle-plane corona discharge, its surface trapping parameters are calculated with the isothermal current theory, and the correlative curve between the surface trap density and its energy level is obtained. The maximum density of electron traps and hole traps in the surface layer of PTFE presents a similar value of ∼2.7 × 1017 eV-1 m-3, and the energy level of its electron and hole traps is of about 0.85-1.0 eV and 0.80-0.90 eV, respectively. Via the X-ray photoelectron spectroscopy (XPS) technique, the F, C, K and O elements are detected on the surface of PTFE samples, and F shows a remarkable atom proportion of ∼73.3%, quite different from the intrinsic distribution corresponding to its chemical formula. The electron traps are attributed to quantities of F atoms existing on the surface of PTFE due to its molecular chain with C atoms surrounded by F atoms spirally. It is considered that the distortions of chemical and electronic structure on solid surface are responsible for the flashover phenomena occurring at a low applied voltage.
Tran, Clara T. H.; Kondyurin, Alexey; Hirsh, Stacey L.; McKenzie, David R.; Bilek, Marcela M. M.
2012-01-01
The surface of polytetrafluoroethylene (PTFE) was modified using plasma immersion ion implantation (PIII) with the aim of improving its ability to immobilize yeast. The density of immobilized cells on PIII-treated and -untreated PTFE was compared as a function of incubation time over 24 h. Rehydrated yeast cells attached to the PIII-treated PTFE surface more rapidly, with higher density, and greater attachment strength than on the untreated surface. The immobilized yeast cells were removed mechanically or chemically with sodium hydroxide and the residues left on the surfaces were analysed with Fourier transform infrared spectroscopy-attenuated total reflection (FTIR-ATR) and X-ray photoelectron spectroscopy (XPS). The results revealed that the mechanism of cell attachment on both surfaces differs and a model is presented for each. Rapid attachment on the PIII-treated surface occurs through covalent bonds of cell wall proteins and the radicals on the treated surface. In contrast, on the untreated surface, only physisorbed molecules were found in the residue and lipids were more highly concentrated than proteins. The presence of lipids in the residue was found to be a consequence of damage to the plasma membrane during the rehydration process and the increased cell stress was also apparent by the amount of Hsp12 in the protein residue. The immobilized yeast cells on PIII-treated PTFE were found to be as active as yeast cells in suspension. PMID:22696486
A Rose in Any Other Font Would Not Smell as Sweet: Effects of Perceptual Fluency on Categorization
ERIC Educational Resources Information Center
Oppenheimer, Daniel M.; Frank, Michael C.
2008-01-01
Fluency--the ease with which people process information--is a central piece of information we take into account when we make judgments about the world. Prior research has shown that fluency affects judgments in a wide variety of domains, including frequency, familiarity, and confidence. In this paper, we present evidence that fluency also plays a…
ERIC Educational Resources Information Center
Greene, Irene; Mc Tiernan, Aoife; Holloway, Jennifer
2018-01-01
The current study employed a randomized controlled trial to evaluate the use of peer tutoring and fluency-based instruction to increase mathematics fluency with addition and subtraction computation skills. Forty-one elementary school students between the ages of eight and 12 years participated in the 8-week study using cross-age peer tutoring, Say…
Lim, Sun Gyo; Kim, Jin Hong; Lee, Kee Myung; Shin, Sung Jae; Kim, Chan Gyoo; Kim, Kyung Ho; Kim, Ho Gak; Yang, Chang Heon
2014-07-01
A conformable self-expandable metallic stent was developed to overcome the limitation of previous self-expandable metallic stents. The aim of this study was to evaluate outcomes after placement of conformable covered and uncovered self-expandable metallic stents for palliation of malignant gastroduodenal obstruction. A single-blind, randomized, parallel-group, prospective study were conducted in 4 medical centres between March 2009 and July 2012. 134 patients with unresectable malignant gastroduodenal obstruction were assigned to a covered double-layered (n=66) or uncovered unfixed-cell braided (n=68) stent placement group. Primary analysis was performed to compare re-intervention rates between two groups. 120 patients were analysed (59 in the covered group and 61 in the uncovered group). Overall rates of re-intervention were not significantly different between the two groups: 13/59 (22.0%) in the covered group vs. 13/61 (21.3%) in the uncovered group, p=0.999. Stent migration was more frequent in the covered group than in the uncovered group (p=0.003). The tumour ingrowth rate was higher in the uncovered group than in the covered group (p=0.016). The rates of re-intervention did not significantly differ between the two stents. Conformable covered double-layered and uncovered unfixed-cell braided stents were associated with different patterns of stent malfunction. Copyright © 2014 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
Stager, Sheila V; Jeffries, Keith J; Braun, Allen R
2003-01-01
We used H(2)15O PET to characterize the common features of two successful but markedly different fluency-evoking conditions -- paced speech and singing -- in order to identify brain mechanisms that enable fluent speech in people who stutter. To do so, we compared responses under fluency-evoking conditions with responses elicited by tasks that typically elicit dysfluent speech (quantifying the degree of stuttering and using this measure as a confounding covariate in our analyses). We evaluated task-related activations in both stuttering subjects and age- and gender-matched controls. Areas that were either uniquely activated during fluency-evoking conditions, or in which the magnitude of activation was significantly greater during fluency-evoking than dysfluency-evoking tasks included auditory association areas that process speech and voice and motor regions related to control of the larynx and oral articulators. This suggests that a common fluency-evoking mechanism might relate to more effective coupling of auditory and motor systems -- that is, more efficient self-monitoring, allowing motor areas to more effectively modify speech. These effects were seen in both PWS and controls, suggesting that they are due to the sensorimotor or cognitive demands of the fluency-evoking tasks themselves. While responses seen in both groups were bilateral, however, the fluency-evoking tasks elicited more robust activation of auditory and motor regions within the left hemisphere of stuttering subjects, suggesting a role for the left hemisphere in compensatory processes that enable fluency. The reader will learn about and be able to: (1) compare brain activation patterns under fluency- and dysfluency-evoking conditions in stuttering and control subjects; (2) appraise the common features, both central and peripheral, of fluency-evoking conditions; and (3) discuss ways in which neuroimaging methods can be used to understand the pathophysiology of stuttering.
NASA Technical Reports Server (NTRS)
Trigwell, Steve; Boucher, Derrick; Calle, Carlos
2006-01-01
The use of an atmospheric pressure glow discharge (APGD) plasma was used at KSC to increase the hydrophilicity of spaceport materials to enhance their surface charge dissipation and prevent possible ESD in spaceport operations. Significant decreases in charge decay times were observed after tribocharging the materials using the standard KSC tribocharging test. The polarity and amount of charge transferred was dependent upon the effective work function differences between the respective materials. In this study, polyethylene (PE) and polytetrafluoroethylene (PTFE) were exposed to a He+O2 APGD. The pre and post treatment surface chemistry was analyzed by X-ray photoelectron spectroscopy and contact angle measurements. Semi-empirical and ab initio calculations were performed to correlate the experimental results with some plausible molecular and electronic structure features of the oxidation process. For the PE, significant surface oxidation was observed, as indicated by XPS showing C-O, C=O, and O-C=O bonding, and a decrease in the surface contact angle from 98.9 deg to 61.2 deg. For the PTFE, no C-O bonding appeared and the surface contact angle increased indicating the APGD only succeeded in cleaning the PTFE surface without affecting the surface structure. The calculations using the PM3 and DFT methods were performed on single and multiple oligomers to simulate a wide variety of oxidation scenarios. Calculated work function results suggest that regardless of oxidation mechanism, e.g. -OH, =0 or a combination thereof, the experimentally observed levels of surface oxidation are unlikely to lead to a significant change in the electronic structure of PE and that its increased hydrophilic properties are the primary reason for the observed changes in its electrostatic behavior. The calculations for PTFE argue strongly against significant oxidation of that material, as confirmed by the XPS results.
Ozawa, Tadashi C; Sasaki, Takayoshi
2010-03-15
We have designed a new approach to synthesize brookite, i.e., to extract alkali-metal ions from K(0.8)Ti(1.73)Li(0.27)O(4) (KTLO) and to apply simultaneous heat treatment to the remaining lepidocrocite-type layers of TiO(6) octahedra. For the alkali-metal ion extraction and the simultaneous heat treatment, KTLO was heated at 400 degrees C with polytetrafluoroethylene (PTFE) in flowing Ar. PTFE has been found to be an effective agent to extract strongly electropositive alkali-metal ions from KTLO because of the strong electronegativity of F as its component. The product of this reaction consists of a mixture of brookite, K(2)CO(3), LiF, and PTFE derivatives, indicating the complete extraction of K(+) and Li(+) from KTLO and formation of brookite from the lepidocrocite-type layer of TiO(6) octahedra as a template. This brookite has a partial replacement of O(2-) with F(-) and/or slight oxygen deficiency; thus, its color is light-bluish gray. Fully oxidized brookite formation and complete decomposition of PTFE derivatives have been achieved by further heating in flowing air, and coproduced alkali-metal salts have been removed by washing in water. Powder X-ray diffraction, Raman spectroscopy, and chemical analysis results have confirmed that the final brookite product treated at 600 degrees C is single phase, and it is white. The method to extract alkali-metal ions from a crystalline material using PTFE is drastically different from the common methods such as soft-chemical and electrochemical reactions. It is likely that this new synthetic approach is applicable to other layered systems to prepare a diverse family of compounds, including novel metastable ones.
Apathy and Reduced Speed of Processing Underlie Decline in Verbal Fluency following DBS
Foltynie, Tom; Zrinzo, Ludvic; Hyam, Jonathan A.; Limousin, Patricia
2017-01-01
Objective. Reduced verbal fluency is a strikingly uniform finding following deep brain stimulation (DBS) for Parkinson's disease (PD). The precise cognitive mechanism underlying this reduction remains unclear, but theories have suggested reduced motivation, linguistic skill, and/or executive function. It is of note, however, that previous reports have failed to consider the potential role of any changes in speed of processing. Thus, the aim of this study was to examine verbal fluency changes with a particular focus on the role of cognitive speed. Method. In this study, 28 patients with PD completed measures of verbal fluency, motivation, language, executive functioning, and speed of processing, before and after DBS. Results. As expected, there was a marked decline in verbal fluency but also in a timed test of executive functions and two measures of speed of processing. Verbal fluency decline was associated with markers of linguistic and executive functioning, but not after speed of processing was statistically controlled for. In contrast, greater decline in verbal fluency was associated with higher levels of apathy at baseline, which was not associated with changes in cognitive speed. Discussion. Reduced generativity and processing speed may account for the marked reduction in verbal fluency commonly observed following DBS. PMID:28408788
Performance of Brazilian children on phonemic and semantic verbal fluency tasks
Charchat-Fichman, Helenice; Oliveira, Rosinda Martins; da Silva, Andreza Morais
2011-01-01
The most used verbal fluency paradigms are semantic and letter fluency tasks. Studies suggest that these paradigms access semantic memory and executive function and are sensitive to frontal lobe disturbances. There are few studies in Brazilian samples on these paradigms. Objective The present study investigated performance, and the effects of age, on verbal fluency tasks in Brazilian children. The results were compared with those of other studies, and the consistency of the scoring criteria data is presented. Methods A sample of 119 children (7 to 10 years old) was submitted to the three phonemic fluency (F, A, M) tasks and three semantic fluency (animals, clothes, fruits) tasks. The results of thirty subjects were scored by two independent examiners. Results A significant positive correlation was found between the scores calculated by the two independent examiners. Significant positive correlations were found between performance on the semantic fluency task and the phonemic fluency task. The effect of age was significant for both tasks, and a significant difference was found between the 7- and 9-year-old subjects and between the 7- and 10-year-old subjects. The 8-year-old group did not differ to any of the other age groups. Conclusion The pattern of results was similar to that observed in previous Brazilian and international studies. PMID:29213727
Wolk, David A.; Gold, Carl A.; Signoff, Eric D.; Budson, Andrew E.
2009-01-01
Prior work suggests that patients with mild Alzheimer’s disease (AD) often base their recognition memory decisions on familiarity. It has been argued that conceptual fluency may play an important role in the feeling of familiarity. In the present study we measured the effect of conceptual fluency manipulations on recognition judgments of patients with mild AD and older adult controls. “Easy” and “hard” test conditions were created by manipulating encoding depth and list length to yield high and low discrimination, respectively. When the two participant groups performed identical procedures, AD patients displayed lower discrimination and greater reliance on fluency cues than controls. However, when the discrimination of older adult controls was decreased to the level of AD patients by use of a shallow encoding task, we found that controls reliance on fluency did not statistically differ from AD patients. Furthermore, we found that increasing discrimination using shorter study lists resulted in AD patients decreasing their reliance on fluency cues to a similar extent as controls. These findings support the notion that patients with AD are able to attribute conceptual fluency to prior experience. In addition these findings suggest that discrimination and reliance on fluency cues may be inversely related in both AD patients and older adult controls. PMID:19428418
Model Filled Polymers. 6. Determination of the Crosslink Density of Polymeric Beads by Swelling
1990-08-22
7 References [1] M. Mooney , J. AppI. Phys., 11, 582 (1940). [2] R. S. Rivlin , and D. W. Sanders, Trans. Faraday Soc., 48, 200 (1952). [31 P. J. Flory...microbeads ranging in diameter from 0.2 to 1 p were prepared by emulsion polymerization in the absence of emulsifier [23]. Polytetrafluorethylene ( PTFE ...density of polymethyl methacrylate is 1.17 g/cm3 [201. Swelling A PTFE ultrafiltration membrane is weighed and inserted in a concave configuration
Granulated lead oxides with teflon
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nilsson, O.
An improvement in the production of tube electrodes for lead storage batteries comprising mixing a small amount (0.1 to 3 weight percent) of polytetrafluoroethylene (Ptfe) with lead powder, the mixture is heated and shear stresses are applied thereto sufficient to convert substantially all of the ptfe in the mixture to fibrous form and to form a non-powdery dough. The dough is then granulated and the doughy granules about 100 mu to 500 mu in major dimension are used for filling tube elctrodes a lead-acid storage battery.
Low-Flammability PTFE for High-Oxygen Environments
NASA Technical Reports Server (NTRS)
Walle, E.; Fallon, B.; Sheppard, A.
1986-01-01
Modified forming process removes volatile combustible materials. Flammability of cable-wrapping tape reduced by altering tape-manufacturing process. In new manufacturing process, tape formed by proprietary process of screw extrusion, followed by washing in solvent and drying. Tape then wrapped as before. Spectrogram taken after extrusion, washing, and drying shows lower hydrocarbon content. PTFE formed by new process suited to oxygen-rich environments. Safe in liquid oxygen of Space Shuttle tank and in medical uses; thin-wall shrinkable tubing in hospital test equipment, surgical instruments, and implants.
Lamp system with conditioned water coolant and diffuse reflector of polytetrafluorethylene(PTFE)
Zapata, Luis E.; Hackel, Lloyd
1999-01-01
A lamp system with a very soft high-intensity output is provided over a large area by water cooling a long-arc lamp inside a diffuse reflector of polytetrafluorethylene (PTFE) and titanium dioxide (TiO.sub.2) white pigment. The water is kept clean and pure by a one micron particulate filter and an activated charcoal/ultraviolet irradiation system that circulates and de-ionizes and biologically sterilizes the coolant water at all times, even when the long-arc lamp is off.
36 CFR 230.20 - Scope and authority.
Code of Federal Regulations, 2012 CFR
2012-07-01
... other members of the public to: maintain, expand, and preserve forest and tree cover; expand research and education efforts related to trees and forest cover; enhance technical skills and understanding of... 36 Parks, Forests, and Public Property 2 2012-07-01 2012-07-01 false Scope and authority. 230.20...
Processing fluency affects subjective claims of recollection.
Kurilla, Bran P; Westerman, Deanne L
2008-01-01
Previous studies that have used the remember-know paradigm to investigate subjective awareness in memory have shown that fluency manipulations have an impact on "know" responses but not on "remember" responses (e.g., Rajaram, 1993), a finding typically accounted for by invoking inferential processing in judgments of familiarity but not of recollection. However, in light of several researchers' criticisms of this procedure, as well as findings documenting the influence of processing fluency on various subjective judgments, the present study was conducted in order to investigate whether judgments of recollection might also be subject to inferential processes and not solely the product of conscious retrieval. When the standard remember-know procedure was used (Experiment 1), manipulations of perceptual fluency increased "know" responses but had no effect on "remember" responses, replicating previous findings. However, when an independent ratings method was employed (Higham & Vokey, 2004), manipulations of perceptual fluency (Experiment 2) and conceptual fluency (Experiment 3) reliably increased claims of both familiarity and recollection, suggesting that the conclusion that fluency affects only "know" responses may be an artifact of the standard remember-know procedure.
Casals-Coll, M; Sánchez-Benavides, G; Quintana, M; Manero, R M; Rognoni, T; Calvo, L; Palomo, R; Aranciva, F; Tamayo, F; Peña-Casanova, J
2013-01-01
Lexical fluency tests are frequently used in clinical practice to assess language and executive function. As part of the Spanish normative studies project in young adults (NEURONORMA young adults project), we provide age- and education-adjusted normative data for 3 semantic fluency tasks (animals, fruits and vegetables, and kitchen tools), three formal lexical fluency tasks (words beginning with P, M and R), three excluded-letter fluency tasks (words excluding A, E and S) and a verb fluency task. The sample consisted of 179 participants who are cognitively normal and range in age from 18 to 49 years. Tables are provided to convert raw scores to scaled scores. Age- and education-adjusted scores are provided by applying linear regression techniques. The results show that education impacted most of the verbal fluency test scores, with no effects related to age and only minimal effects related to sex. The norms obtained will be extremely useful in the clinical evaluation of young Spanish adults. Copyright © 2011 Sociedad Española de Neurología. Published by Elsevier Espana. All rights reserved.
Intuitive (in)coherence judgments are guided by processing fluency, mood and affect.
Sweklej, Joanna; Balas, Robert; Pochwatko, Grzegorz; Godlewska, Małgorzata
2014-01-01
Recently proposed accounts of intuitive judgments of semantic coherence assume that processing fluency results in a positive affective response leading to successful assessment of semantic coherence. The present paper investigates whether processing fluency may indicate semantic incoherence as well. In two studies, we employ a new paradigm in which participants have to detect an incoherent item among semantically coherent words. In Study 1, we show participants accurately indicating an incoherent item despite not being able to provide an accurate solution to coherent words. Further, this effect is modified by affective valence of solution words that are not retrieved from memory. Study 2 replicates those results and extend them by showing that mood moderates incoherence judgments independently of affective valence of solutions. The results support processing fluency account of intuitive semantic coherence judgments and show that it is not fluency per se but fluency variations that drive judgments.
Prediction and stability of reading problems in middle childhood.
Ritchey, Kristen D; Silverman, Rebecca D; Schatschneider, Christopher; Speece, Deborah L
2015-01-01
The longitudinal prediction of reading problems from fourth grade to sixth grade was investigated with a sample of 173 students. Reading problems at the end of sixth grade were defined by significantly below average performance (≤ 15th percentile) on reading factors defining word reading, fluency, and reading comprehension. Sixth grade poor reader status was predicted by fall of fourth grade passage reading fluency, spelling fluency, and the number of reading problems identified by teachers. Reading fluency and spelling fluency were significant predictors in logistic regression equation that combined to yield a screening battery with an area under the curve of .91. These results suggest that brief assessments of reading and spelling fluency in fourth grade may be able to identify students in middle childhood who have a reading problem or who are at risk for experiencing reading problems in sixth grade. © Hammill Institute on Disabilities 2013.
NASA Astrophysics Data System (ADS)
George, Michael G.; Wang, Jian; Banerjee, Rupak; Bazylak, Aimy
2016-03-01
The novel application of scanning transmission X-ray microscopy (STXM) to the microporous layer (MPL) of a polymer electrolyte membrane fuel cell is investigated. A spatially resolved chemical component distribution map is obtained for the MPL of a commercially available SGL 25 BC sample. This is achieved with near edge X-ray absorption fine structure spectroscopic analysis. Prior to analysis the sample is embedded in non-reactive epoxy and ultra-microtomed to a thickness of 100 nm. Polytetrafluoroethylene (PTFE), carbon particle agglomerates, and supporting epoxy resin distributions are identified and reconstructed for a scanning area of 6 μm × 6 μm. It is observed that the spatial distribution of PTFE is strongly correlated to the carbon particle agglomerations. Additionally, agglomerate structures of PTFE are identified, possibly indicating the presence of a unique mesostructure in the MPL. STXM analysis is presented as a useful technique for the investigation of chemical species distributions in the MPL.
NASA Astrophysics Data System (ADS)
Yong, Jiale; Fang, Yao; Chen, Feng; Huo, Jinglan; Yang, Qing; Bian, Hao; Du, Guangqing; Hou, Xun
2016-12-01
Separating the mixture of water and oil by the superhydrophobic porous materials has attracted increasing research interests; however, the surface microstructures and chemical composition of those materials are easily destroyed in a harsh environment, resulting in materials losing the superhydrophobicity as well as the oil/water separation function. In this paper, a kind of rough microstructures was formed on polytetrafluoroethylene (PTFE) sheet by femtosecond laser treatment. The rough surfaces showed durable superhydrophobicity and ultralow water adhesion even after storing in various harsh environment for a long time, including strong acid, strong alkali, and high temperature. A micro-through-holes array was further generated on the rough superhydrophobic PTFE film by a subsequent mechanical drilling process. The resultant sample was successfully applied in the field of oil/water separation due to the inverse superhydrophobicity and superoleophilicity. The designed separation system is also very efficient to separate the mixtures of oil and corrosive acid/alkali solutions, exhibiting the strong potential for practical application.
NASA Astrophysics Data System (ADS)
Sadeghifar, Hamidreza; Djilali, Ned; Bahrami, Majid
2015-01-01
This paper reports on measurements of thermal conductivity of a graphite bipolar plate (BPP) as a function of temperature and its thermal contact resistance (TCR) with treated and untreated gas diffusion layers (GDLs). The thermal conductivity of the BPP decreases with temperature and its thermal contact resistance with GDLs, which has been overlooked in the literature, is found to be dominant over a relatively wide range of compression. The effects of PTFE loading, micro porous layer (MPL), compression, and BPP out-of-flatness are also investigated experimentally. It is found that high PTFE loadings, MPL and even small BPP out-of-flatness increase the BPP-GDL thermal contact resistance dramatically. The paper also presents the effect of cyclic load on the total resistance of a GDL-BPP assembly, which sheds light on the behavior of these materials under operating conditions in polymer electrolyte membrane fuel cells.
[Air pollution due to the burning of thermoplastics II (author's transl)].
van Grimbergen, M; Reybrouck, G; van de Voorde, H
1975-03-01
Following on from the first publication, (12) concerning the burning of plastics, another 13 chemical pure polymers were burnt in an electric oven to determine the level of solid and gaseous air pollution caused by their stackgases. All 13 polymers are highly combustible but require different burning temperatures (300-900 degrees C) in order to be burnt completely (i.e. without ashrest). With the exception of PMMA and PTFE, all plastics leave a very heavy tar- and soot deposit after burning. At the other end of the scale, burning at low temperature (300 degrees C) gives rise to high concentrations of alipathic aldehyds. The pH of the exhaust-gases, dissolved in water, is neutral to strong acid (PTFE), and will cause a severe corrosion. The nitrogen-containing polymers pollute by forming cyanides, nitrogenoxides and ammonia. PTFE gives off high concentrations of fluorid into the air. PMMA decomposes in its monomer methylmethacrylate and forms large amounts of aliphatic aldehyds. ABS and SBR cause a styrene pollution.
NASA Astrophysics Data System (ADS)
Wyszkowska, Edyta; Leśniak, Magdalena; Kurpaska, Lukasz; Prokopowicz, Rafal; Jozwik, Iwona; Sitarz, Maciej; Jagielski, Jacek
2018-04-01
In this study structural and nanomechanical properties of polytetrafluoroethylene (PTFE) used as a gasket in the nuclear reactor have been deeply investigated. In order to reveal structural changes caused by long-term pressure, temperature and irradiation (possibly neutron and gamma), methods such as SEM, X-ray diffraction and Raman Spectroscopy have been used. Nanomechanical properties such as Young Modulus and hardness were investigated by means of the nanoindentation technique. Presented study confirmed the influence of working (radiative) environment on the functional properties of PTFE. The results of Raman spectroscopy and X-ray diffraction techniques revealed shift of the major band positions and band intensities increase. Moreover, changes of hardness and Young Modulus values of the irradiated material with respect to the virgin specimen have been recorded. This phenomenon can be attributed to the modifications in crystallinity of the material. Presented work suggest that morphology of the irradiated material altered from well-ordered parallel fibers to more dense and thicker ones.
Székács, Inna; Kaszás, Nóra; Gróf, Pál; Erdélyi, Katalin; Szendrő, István; Mihalik, Balázs; Pataki, Ágnes; Antoni, Ferenc A.; Madarász, Emilia
2013-01-01
Optical waveguide lightmode spectroscopic (OWLS) techniques were probed for monitoring ion permeation through channels incorporated into artificial lipid environment. A novel sensor set-up was developed by depositing liposomes or cell-derived membrane fragments onto hydrophilic polytetrafluoroethylene (PTFE) membrane. The fibrous material of PTFE membrane could entrap lipoid vesicles and the water-filled pores provided environment for the hydrophilic domains of lipid-embedded proteins. The sensor surface was kept clean from the lipid holder PTFE membrane by a water- and ion-permeable polyethylene terephthalate (PET) mesh. The sensor set-up was tested with egg yolk lecithin liposomes containing gramicidin ion channels and with cell-derived membrane fragments enriched in GABA-gated anion channels. The method allowed monitoring the move of Na+ and organic cations through gramicidin channels and detecting the Cl–-channel functions of the (α5β2γ2) GABAA receptor in the presence or absence of GABA and the competitive GABA-blocker bicuculline. PMID:24339925
Decomposition pathways of polytetrafluoroethylene by co-grinding with strontium/calcium oxides.
Qu, Jun; He, Xiaoman; Zhang, Qiwu; Liu, Xinzhong; Saito, Fumio
2017-06-01
Waste polytetrafluoroethylene (PTFE) could be easily decomposed by co-grinding with inorganic additive such as strontium oxide (SrO), strontium peroxide (SrO 2 ) and calcium oxide (CaO) by using a planetary ball mill, in which the fluorine was transformed into nontoxic inorganic fluoride salts such as strontium fluoride (SrF 2 ) or calcium fluoride (CaF 2 ). Depending on the kind of additive as well as the added molar ratio, however, the reaction mechanism of the decomposition was found to change, with different compositions of carbon compounds formed. CO gas, the mixture of strontium carbonate (SrCO 3 ) and carbon, only SrCO 3 were obtained as reaction products respectively with equimolar SrO, excess SrO and excess SrO 2 to the monomer unit CF 2 of PTFE were used. Excess amount of CaO was needed to effectively decompose PTFE because of its lower reactivity compared with strontium oxide, but it promised practical applications due to its low cost.
Off-normal deposition of PTFE thin films during 157-nm irradiation
NASA Astrophysics Data System (ADS)
George, Sharon R.; Langford, Stephen C.; Dickinson, J. Thomas
2010-03-01
Polytetrafluoroethylene (PTFE) is valued for its chemical stability, low surface energy, and insulating properties. The ablation of PTFE by F2 excimer lasers (157 nm photons) involves photochemical scission of C-C bonds along the polymer chain. Depending on the fluence, the fragment masses can range from 50 to 2000 amu. Gaussian beam profiles allow for the production of spatially non-uniform distributions of fragment masses, with the lighter fragments concentrated in the center of the laser spot. The resulting trajectories for the light fragments can be strongly forward directed, while the heavy fragments are directed more to the side, well away from the surface normal. We present experimental evidence for these angular distributions, and numerically simulate this behavior with a simple, two-component hydrodynamic model. Under the conditions of our work, most of the ablated mass appears as heavier fragments and can be collected on substrates mounted to the sides or above and below the laser spot. This geometry may have advantages in some applications of pulsed laser deposition.
Abdel Samie, Ahmed; Theilmann, Lorenz
2012-01-01
Transpapillary stents are increasingly being used for biliary strictures, whether benign or malignant. However, there are different stent types and available data is controversial. Recently, completely covered self-expandable metal stents (CSEMSs) have been proposed as an alternative therapeutic option in different biliary indications, including strictures of the distal bile duct, anastomotic stenosis after orthotopic liver transplantation, bile duct leaks, periampullary perforation following endoscopic sphincterotomy (ES), and postsphincterotomy bleeding. Despite the higher costs of these devices, fully covered self-expanding metal stents seem to be a suitable therapeutic option to relief biliary obstruction due to bile duct stenosis, regardless of the underlying cause. PMID:22761543
Panos, Joseph A.; Hoffman, Joshua T.; Wordeman, Samuel C.; Hewett, Timothy E.
2016-01-01
Background Correction of neuromuscular impairments after anterior cruciate ligament injury is vital to successful return to sport. Frontal plane knee control during landing is a common measure of lower-extremity neuromuscular control and asymmetries in neuromuscular control of the knee can predispose injured athletes to additional injury and associated morbidities. Therefore, this study investigated the effects of anterior cruciate ligament injury on knee biomechanics during landing. Methods Two-dimensional frontal plane video of single leg drop, cross over drop, and drop vertical jump dynamic movement trials was analyzed for twenty injured and reconstructed athletes. The position of the knee joint center was tracked in ImageJ software for 500 milliseconds after landing to calculate medio-lateral knee motion velocities and determine normal fluency, the number of times per second knee velocity changed direction. The inverse of this calculation, analytical fluency, was used to associate larger numerical values with fluent movement. Findings Analytical fluency was decreased in involved limbs for single leg drop trials (P=0.0018). Importantly, analytical fluency for single leg drop differed compared to cross over drop trials for involved (P<0.001), but not uninvolved limbs (P=0.5029). For involved limbs, analytical fluency values exhibited a stepwise trend in relative magnitudes. Interpretation Decreased analytical fluency in involved limbs is consistent with previous studies. Fluency asymmetries observed during single leg drop tasks may be indicative of abhorrent landing strategies in the involved limb. Analytical fluency differences in unilateral tasks for injured limbs may represent neuromuscular impairment as a result of injury. PMID:26895446
Krukow, Paweł; Harciarek, Michał; Morylowska-Topolska, Justyna; Karakuła-Juchnowicz, Hanna; Jonak, Kamil
2017-09-01
Patients with schizophrenia (SCH) show impaired verbal and non-verbal fluency. However, these individuals' fluctuations in words or designs generation efficiency over time, a phenomenon that may significantly affect fluency, have never been studied. Thus, the aim of this research was to investigate if individuals with SCH may present with alternations in the dynamics of the information production and its control as well as to test if the potential abnormalities in this regard might affect these patients' overall performance on both verbal and non-verbal fluency tasks. Forty-four patients with SCH and 40 healthy controls (HC) completed both verbal (phonological, semantic) and non-verbal fluency tests. To analyse processing efficiency changes over time, the period in which subjects had to generate words or designs (60 s) has been divided into 15-s sections. In comparison to HCs, individuals with SCH obtained significantly lower total scores for all fluency measures. Furthermore, group differences in the dynamics of the test performance also emerged, with SCH patients having a significantly worse production during the initial 15 s of each fluency task. Additionally, the initial production deficiency seen in patients with SCH has accounted for these individuals' total performance. Moreover, comparisons of errors distribution over time during the phonemic and figural fluency performance also revealed differences, suggesting there was a rapid depletion in maintaining of cognitive control in the SCH sample. Inefficient fluency in SCH may arise from a more general initiation deficits that may partly account for these patients' cognitive problems.
Effects of disfluency in writing.
Medimorec, Srdan; Risko, Evan F
2016-11-01
While much previous research has suggested that decreased transcription fluency has a detrimental effect on writing, there is recent evidence that decreased fluency can actually benefit cognitive processing. Across a series of experiments, we manipulated transcription fluency of ostensibly skilled typewriters by asking them to type essays in two conditions: both-handed and one-handed typewriting. We used the Coh-Metrix text analyser to investigate the effects of decreased transcription fluency on various aspects of essay writing, such as lexical sophistication, sentence complexity, and cohesion of essays (important indicators of successful writing). We demonstrate that decreased fluency can benefit certain aspects of writing and discuss potential mechanisms underlying disfluency effects in essay writing. © 2016 The British Psychological Society.
Testing of Shelter Design and Industrial Hardening Concepts at the MILL RACE Event.
1982-01-01
built. The upgrading consisted of the application of 2-in. thick sheets of expanded polystyrene to the exterior of each of the test walls to be upgraded...was covered with 1-in. thick sheets of expanded polystyrene prior to backfilling (Figure 6-4), and the interior was shored, floor to ceiling, with two...deformations in the vault, despite the fact that no structural upgrading options (shores, or roof cover of expanded polystyrene ) were installed. Thus
Mehta, J S; Futter, C E; Sandeman, S R; Faragher, R G A F; Hing, K A; Tanner, K E; Allan, B D S
2005-10-01
Published clinical series suggest the osteoodontokeratoprosthesis (OOKP) may have a lower extrusion rate than current synthetic keratoprostheses. The OOKP is anchored in the eye wall by autologous tooth. The authors' aim was to compare adhesion, proliferation, and morphology for telomerase transformed keratocytes seeded on calcium hydroxyapatite (the principal mineral constituent of tooth) and materials used in the anchoring elements of commercially available synthetic keratoprostheses. Test materials were hydroxyapatite, polytetrafluoroethylene (PTFE), polyhydroxyethyl methacrylate (HEMA), and glass (control). Cell adhesion and viability were quantified at 4 hours, 24 hours, and 1 week using a calcein-AM/EthD-1 viability/cytotoxicity assay. Focal contact expression and cytoskeletal organisation were studied at 24 hours by confocal microscopy with immunoflourescent labelling. Further studies of cell morphology were performed using light and scanning electron microscopy. Live cell counts were significantly greater on hydroxyapatite surfaces at each time point (p<0.04). Dead cell counts were significantly higher for PTFE at 7 days (p<0.002). ss(1) integrin expression was highest on hydroxyapatite. Adhesion structures were well expressed in flat, spread out keratocytes on both HA and glass. Keratocytes tended to be thinner and spindle shaped on PTFE. The relatively few keratocytes visible on HEMA test surfaces were rounded and poorly adherent. Keratocyte adhesion, spreading, and viability on hydroxyapatite test surfaces is superior to that seen on PTFE and HEMA. Improving the initial cell adhesion environment in the skirt element of keratoprostheses may enhance tissue integration and reduce device failure rates.
NASA Astrophysics Data System (ADS)
Duman, M. S.; Kaplan, E.; Cuvalcı, O.
2018-01-01
The present paper is based on experimental studies and numerical simulations on the surface fatigue failure of the PTFE-bronze layered journal bearings under real-time loading. ‘Permaglide Plain Bearings P10’ type journal bearings were experimentally tested under different real time dynamic loadings by using real time journal bearing test system in our laboratory. The journal bearing consists of a PTFE-bronze layer approximately 0.32 mm thick on the steel support layer with 2.18 mm thick. Two different approaches have been considered with in experiments: (i) under real- time constant loading with varying bearing widths, (ii) under different real-time loadings at constant bearing widths. Fatigue regions, micro-crack dispersion and stress distributions occurred at the journal bearing were experimentally and theoretically investigated. The relation between fatigue region and pressure distributions were investigated by determining the circumferential pressure distribution under real-time dynamic loadings for the position of every 10° crank angles. In the theoretical part; stress and deformation distributions at the surface of the journal bearing analysed by using finite element methods to determine the relationship between stress and fatigue behaviour. As a result of this study, the maximum oil pressure and fatigue cracks were observed in the most heavily loaded regions of the bearing surface. Experimental results show that PTFE-Bronze layered journal bearings fatigue behaviour is better than the bearings include white metal alloy.
Huang, Kang; Goddard, Julie M
2015-09-01
Application of nonfouling coatings on thermal processing equipment can improve operational efficiency. However, to enable effective commercial translation, a need exists for more comprehensive studies on the stability of nonfouling coatings after exposure to different sanitizers. In the current study, the influence of different commercial dairy equipment sanitizers on the nonfouling properties of stainless steel modified with electroless Ni-polytetrafluoroethylene (PTFE) coatings was determined. Surface properties, such as dynamic contact angle, surface energy, surface morphology, and elemental composition, were measured before and after the coupons were exposed to the sanitizers for 168 cleaning cycles. The fouling behavior of Ni-PTFE-modified stainless steel coupons after exposure was also evaluated by processing raw milk on a self-fabricated benchtop-scale plate heat exchanger. The results indicated that peroxide sanitizer had only minor effect on the Ni-PTFE-modified stainless steel surface, whereas chlorine- and iodine-based sanitizers influenced the surface properties drastically. The coupons after 168 cycles of exposure to peroxide sanitizer accumulated the least amount of fouling material (4.44±0.24mg/cm(2)) compared with the coupons exposed to the other 3 sanitizers. These observations indicated that the Ni-PTFE nonfouling coating retained antifouling properties after 168 cycles of exposure to peroxide-based sanitizer, supporting their potential application as nonfouling coatings for stainless steel dairy processing equipment. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Hou, Meifang; Chu, Yaofei; Li, Xiang; Wang, Huijiao; Yao, Weikun; Yu, Gang; Murayama, Seiichi; Wang, Yujue
2016-12-05
This study compares the degradation of diethyl phthalate (DEP) by the electro-peroxone (E-peroxone) process with three different carbon-based cathodes, namely, carbon-polytetrafluorethylene (carbon-PTFE), carbon felt, and reticulated vitreous carbon (RVC). Results show that the three cathodes had different electrocatalytic activity for converting sparged O2 to H2O2, which increased in order of carbon felt, RVC, and carbon-PTFE. The in-situ generated H2O2 then reacts with sparged O3 to yield OH, which can in turn oxidize ozone-refractory DEP toward complete mineralization. In general, satisfactory total organic carbon removal yields (76.4-91.8%) could be obtained after 60min of the E-peroxone treatment with the three carbon-based cathodes, and the highest yield was obtained with the carbon-PTFE cathode due to its highest activity for H2O2 generation. In addition, the carbon-PTFE and carbon felt cathodes exhibited excellent stability over six cycles of the E-peroxone treatment of DEP solutions. Based on the intermediates (e.g., monoethyl phthalate, phthalic acid, phenolics, and carboxylic acids) identified by HPLC-UV, plausible reaction pathways were proposed for DEP mineralization by the E-peroxone process. The results of this study indicate that carbon-based cathodes generally have good electrocatalytic activity and stability for application in extended E-peroxone operations to effectively remove phthalates from water. Copyright © 2015 Elsevier B.V. All rights reserved.
Tian, Jiangnan; Olajuyin, Ayobami Matthew; Mu, Tingzhen; Yang, Maohua; Xing, Jianmin
2016-06-01
The electro-Fenton (EF) process treatment of 0.1-M (rhodamine B) RhB solution was studied with different graphite cathode materials, and graphite felt (GF) was selected as a promising material in further investigation. Then, the degradation performances of gas diffusion electrode (GDE) and graphite felt (GF) were compared, and GDE was confirmed to be more efficient in RhB removal. The operational parameters such as Fe(2+) dosage and current density were optimized, and comparison among different modified methods-polytetrafluoroethylene-carbon black (PTFE-CB), polytetrafluoroethylene-carbon nanotube (PTFE-CNT), electrodeposition-CB, and electrodeposition-CNT-showed 98.49 % RhB removal by PTFE-CB-modified cathode in 0.05 M Na2SO4 at a current density of 50 A/m(2) and an air flow rate of 1 L/min after 20 min. Meanwhile, after cathode modified by PTFE-CB, the mineralization efficiency and mineralization current efficiency performed absolutely better than the pristine one. Cyclic voltammograms, SEM images, contact angles, and BET surface area were carried out to demonstrate stronger current responses and higher hydrophilicity of GF after modified. The value of biochemical oxygen demand/chemical oxygen demand (BOD5/COD) increased from 0.049 to 0.331 after 90-min treatment, suggesting the solution was biodegradable, and the modified cathode was confirmed to be stable after ten circle runs. Finally, a proposed degradation pathway of RhB was put forward.
Marshall, D F; Strutt, A M; Williams, A E; Simpson, R K; Jankovic, J; York, M K
2012-12-01
Despite common occurrences of verbal fluency declines following bilateral subthalamic nucleus deep brain stimulation (STN-DBS) for the treatment of Parkinson's disease (PD), alternating fluency measures using cued and uncued paradigms have not been evaluated. Twenty-three STN-DBS patients were compared with 20 non-surgical PD patients on a comprehensive neuropsychological assessment, including cued and uncued intradimensional (phonemic/phonemic and semantic/semantic) and extradimensional (phonemic/semantic) alternating fluency measures at baseline and 6-month follow-up. STN-DBS patients demonstrated a greater decline on the cued phonemic/phonemic fluency and the uncued phonemic/semantic fluency tasks compared to the PD patients. For STN-DBS patients, verbal learning and information processing speed accounted for a significant proportion of the variance in declines in alternating phonemic/phonemic and phonemic/semantic fluency scores, respectively, whilst only naming was related to uncued phonemic/semantic performance for the PD patients. Both groups were aided by cueing for the extradimensional task at baseline and follow-up, and the PD patients were also aided by cueing for the phonemic/phonemic task on follow-up. These findings suggest that changes in alternating fluency are not related to disease progression alone as STN-DBS patients demonstrated greater declines over time than the PD patients, and this change was related to declines in information processing speed. © 2012 The Author(s) European Journal of Neurology © 2012 EFNS.
Carry-over fluency induced by extreme prolongations: A new behavioral paradigm.
Briley, P M; Barnes, M P; Kalinowski, J S
2016-04-01
Extreme prolongations, which can be generated via extreme delayed auditory feedback (DAF) (e.g., 250-500 ms) or mediated cognitively with timing applications (e.g., analog stopwatch) at 2 s per syllable, have long been behavioral techniques used to inhibit stuttering. Some therapies have used this rate solely to establish initial fluency, while others use extremely slowed speech to establish fluency and add other strategic techniques such as easy onsets and diaphragmatic breathing. Extreme prolongations generate effective, efficient, and immediate forward flowing fluent speech, removing the signature behaviors of discrete stuttering (i.e., syllable repetitions and audible and inaudible postural fixations). Prolonged use of extreme prolongations establishes carry-over fluency, which is spontaneous, effortless speech absent of most, if not all, overt and covert manifestations of stuttering. The creation of this immediate fluency and the immense potential of extreme prolongations to generate long periods of carry-over fluency have been overlooked by researchers and clinicians alike. Clinicians depart from these longer prolongation durations as they attempt to achieve the same fluent results at a near normal rate of speech. Clinicians assume they are re-teaching fluency and slow rates will give rise to more normal rates with less control, but without carry-over fluency, controls and cognitive mediation are always needed for the inherently unstable speech systems of persons who stutter to experience fluent speech. The assumption being that the speech system is untenable without some level of cognitive and motoric monitoring that is always necessary. The goal is omnipresent "near normal rate sounding fluency" with continuous mediation via cognitive and motoric processes. This pursuit of "normal sounding fluency" continues despite ever-present relapse. Relapse has become so common that acceptance of stuttering is the new therapy modality because relapse has come to be understood as somewhat inevitable. Researchers and clinicians fail to recognize that immediate amelioration of stuttering and its attendant carry-over fluency are signs of a different pathway to fluency. In this path, clinicians focus on extreme prolongations and the extent of their carry-over. While fluency is automatically generated under these extreme prolongations, the realization is that communication at this rate in routine speaking tasks is not feasible. The perceived solution is a systematic reduction in the duration of these prolongations, which attempts to approximate "normal speech." Typically, the reintroduction of speech at a normalized rate precipitates a laborious style that is undesirable to the person who stutters (PWS) and is discontinued, once departed from the comforts of the clinical setting. The inevitable typically occurs; the well-intentioned therapist instructs the PWS to focus on the techniques while speaking at a rate that is nearest normal speech, but the overlooked extreme prolongations are unlikely to ever be revisited. The foundation of this hypothesis is that the departure from fluency generators (e.g. extreme prolongations) is the cause of regression to the stuttering set point. In turn, we postulate that the continued use of extreme prolongations, as a solitary practice method, will establish and nurture different neural pathways that will create a modality of fluent speech, able to be experienced without cognitive or motoric mediation. This would therefore result in fewer occurrences of stuttering due to a phenomenon called carry-over fluency. Thus, we hypothesize that the use of extreme prolongations fosters neural pathways for fluent speech, which will result in carry-over fluency that does not require mediation by the speaker. Copyright © 2016 Elsevier Ltd. All rights reserved.
Laughing through Rereadings: Using Joke Books to Build Fluency
ERIC Educational Resources Information Center
Ness, Molly
2009-01-01
The author explores how the use of joke books can promote fluency in young readers. One young girl's fluency improved measurably, and her engagement and motivation to read the particular kind of text involved played a significant role. (Contains 2 tables.)
Implementing an Effective Mathematics Fact Fluency Practice Activity
ERIC Educational Resources Information Center
Riccomini, Paul J.; Stocker, James D., Jr.; Morano, Stephanie
2017-01-01
Proficiency in mathematics involves the seamless synchronization of conceptual understanding, procedural knowledge, computational fluency, and problem solving (NMAP, 2008). Clearly, fluency with mathematics facts is one element embedded within mathematical proficiency and important for students with disabilities to develop. As more and more…
Davidow, Jason H
2014-01-01
Metronome-paced speech results in the elimination, or substantial reduction, of stuttering moments. The cause of fluency during this fluency-inducing condition is unknown. Several investigations have reported changes in speech pattern characteristics from a control condition to a metronome-paced speech condition, but failure to control speech rate between conditions limits our ability to determine if the changes were necessary for fluency. This study examined the effect of speech rate on several speech production variables during one-syllable-per-beat metronomic speech in order to determine changes that may be important for fluency during this fluency-inducing condition. Thirteen persons who stutter (PWS), aged 18-62 years, completed a series of speaking tasks. Several speech production variables were compared between conditions produced at different metronome beat rates, and between a control condition and a metronome-paced speech condition produced at a rate equal to the control condition. Vowel duration, voice onset time, pressure rise time and phonated intervals were significantly impacted by metronome beat rate. Voice onset time and the percentage of short (30-100 ms) phonated intervals significantly decreased from the control condition to the equivalent rate metronome-paced speech condition. A reduction in the percentage of short phonated intervals may be important for fluency during syllable-based metronome-paced speech for PWS. Future studies should continue examining the necessity of this reduction. In addition, speech rate must be controlled in future fluency-inducing condition studies, including neuroimaging investigations, in order for this research to make a substantial contribution to finding the fluency-inducing mechanism of fluency-inducing conditions. © 2013 Royal College of Speech and Language Therapists.
Davidow, Jason H.
2013-01-01
Background Metronome-paced speech results in the elimination, or substantial reduction, of stuttering moments. The cause of fluency during this fluency-inducing condition is unknown. Several investigations have reported changes in speech pattern characteristics from a control condition to a metronome-paced speech condition, but failure to control speech rate between conditions limits our ability to determine if the changes were necessary for fluency. Aims This study examined the effect of speech rate on several speech production variables during one-syllable-per-beat metronomic speech, in order to determine changes that may be important for fluency during this fluency-inducing condition. Methods and Procedures Thirteen persons who stutter (PWS), aged 18–62 years, completed a series of speaking tasks. Several speech production variables were compared between conditions produced at different metronome beat rates, and between a control condition and a metronome-paced speech condition produced at a rate equal to the control condition. Outcomes & Results Vowel duration, voice onset time, pressure rise time, and phonated intervals were significantly impacted by metronome beat rate. Voice onset time and the percentage of short (30–100 ms) phonated intervals significantly decreased from the control condition to the equivalent rate metronome-paced speech condition. Conclusions & Implications A reduction in the percentage of short phonated intervals may be important for fluency during syllable-based metronome-paced speech for PWS. Future studies should continue examining the necessity of this reduction. In addition, speech rate must be controlled in future fluency-inducing condition studies, including neuroimaging investigations, in order for this research to make a substantial contribution to finding the fluency-inducing mechanism of fluency-inducing conditions. PMID:24372888
Measurements of prompt radiation induced conductivity in Teflon (PTFE).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hartman, E. Frederick; Zarick, Thomas Andrew; Sheridan, Timothy J.
2013-05-01
We performed measurements of the prompt radiation induced conductivity (RIC) in thin samples of Teflon (PTFE) at the Little Mountain Medusa LINAC facility in Ogden, UT. Three mil (76.2 microns) samples were irradiated with a 0.5 %CE%BCs pulse of 20 MeV electrons, yielding dose rates of 1E9 to 1E11 rad/s. We applied variable potentials up to 2 kV across the samples and measured the prompt conduction current. Details of the experimental apparatus and analysis are reported in this report on prompt RIC in Teflon.
Real time infrared aerosol analyzer
Johnson, Stanley A.; Reedy, Gerald T.; Kumar, Romesh
1990-01-01
Apparatus for analyzing aerosols in essentially real time includes a virtual impactor which separates coarse particles from fine and ultrafine particles in an aerosol sample. The coarse and ultrafine particles are captured in PTFE filters, and the fine particles impact onto an internal light reflection element. The composition and quantity of the particles on the PTFE filter and on the internal reflection element are measured by alternately passing infrared light through the filter and the internal light reflection element, and analyzing the light through infrared spectrophotometry to identify the particles in the sample.
Can Diastat Grafts Meet the Challenges of Daily Punctures?
Chandran, Prem K G; Messer, Diane; Sidwell, Richard A; Stubbs, David H; Nish, Andrew D
1997-01-01
To determine whether Diastat grafts can meet the challenges of daily needle punctures required for home hemodialysis (HD), a retrospective analysis was performed on the experience with 47 grafts placed in 44 patients receiving HD three times a week. The control group consisted of 17 patients who received 17 stretch polytetrafluoroethylene (s-PTFE) grafts. Apart from their ability to better contain bleeding after needle withdrawal, in all measures of longevity the Diastat grafts were outperformed by the s-PTFE grafts. No more direct data exist to address the original challenge.
Building Speaking Fluency with Multiword Expressions
ERIC Educational Resources Information Center
Thomson, Haidee
2017-01-01
Previous research has shown a link between speaking fluently and using multiword expressions. However, evidence on how to effectively teach multiword expressions is limited. This study investigates the effect of fluency-oriented classroom teaching on speaking fluency, with special attention to multiword expressions. In this quasi-experimental…
Perceptual fluency and judgments of vocal aesthetics and stereotypicality.
Babel, Molly; McGuire, Grant
2015-05-01
Research has shown that processing dynamics on the perceiver's end determine aesthetic pleasure. Specifically, typical objects, which are processed more fluently, are perceived as more attractive. We extend this notion of perceptual fluency to judgments of vocal aesthetics. Vocal attractiveness has traditionally been examined with respect to sexual dimorphism and the apparent size of a talker, as reconstructed from the acoustic signal, despite evidence that gender-specific speech patterns are learned social behaviors. In this study, we report on a series of three experiments using 60 voices (30 females) to compare the relationship between judgments of vocal attractiveness, stereotypicality, and gender categorization fluency. Our results indicate that attractiveness and stereotypicality are highly correlated for female and male voices. Stereotypicality and categorization fluency were also correlated for male voices, but not female voices. Crucially, stereotypicality and categorization fluency interacted to predict attractiveness, suggesting the role of perceptual fluency is present, but nuanced, in judgments of human voices. © 2014 Cognitive Science Society, Inc.
I can, I do, and so I like: From power to action and aesthetic preferences.
Woltin, Karl-Andrew; Guinote, Ana
2015-12-01
The current work tested the hypothesis that power increases reliance on experiences of motor fluency in forming aesthetic preferences. In 4 experiments, participants reported their aesthetic preferences regarding a variety of targets (pictures, movements, objects, and letters). Experiments 1, 2, and 3 manipulated power and motor fluency (via motoric resonance, extraocular muscle training, and dominant hand restriction). Experiment 4 manipulated power and assessed chronic interindividual differences in motor fluency. Across these experiments, power consistently increased reliance on motor fluency in aesthetic preference judgments. This finding was not mediated by differences in mood, judgment certainty, perceived task-demands or task-enjoyment, and derived from the use of motor simulations rather than from power differences in the acquisition of motor experiences. This is the first demonstration suggesting that power changes the formation of preference judgments as a function of motor fluency experiences. The implications of this research for the links between power and action, as well as the understanding of fluency processes are discussed. (c) 2015 APA, all rights reserved).
Harciarek, Michał; Williamson, John B; Biedunkiewicz, Bogdan; Lichodziejewska-Niemierko, Monika; Dębska-Ślizień, Alicja; Rutkowski, Bolesław
2012-01-01
Although dialyzed patients often have cognitive problems, little is known about the nature of these deficits. We hypothesized that, in contrast to semantic fluency relying mainly on temporal lobes, phonemic fluency, preferentially depending on functions of frontal-subcortical systems, would be particularly sensitive to the constellation of physiological pathological processes associated with end-stage renal disease and dialysis. Therefore, we longitudinally compared phonemic and semantic fluency performance between 49 dialyzed patients and 30 controls. Overall, patients performed below controls only on the phonemic fluency task. Furthermore, their performance on this task declined over time, whereas there was no change in semantic fluency. Moreover, this decline was related to the presence of hypertension and higher blood urea nitrogen. We suggest that these findings may be due to a combination of vascular and topic effects that impact more on fronto-subcortical than temporal lobe networks, but this speculation requires direct confirmation.
Evaluating lexical characteristics of verbal fluency output in schizophrenia.
Juhasz, Barbara J; Chambers, Destinee; Shesler, Leah W; Haber, Alix; Kurtz, Matthew M
2012-12-30
Standardized lexical analysis of verbal output has not been applied to verbal fluency tasks in schizophrenia. Performance of individuals with schizophrenia on both a letter (n=139) and semantic (n=137) fluency task was investigated. The lexical characteristics (word frequency, age-of-acquisition, word length, and semantic typicality) of words produced were evaluated and compared to those produced by a healthy control group matched on age, gender, and Wechsler Adult Intelligence Scale-Third Edition (WAIS-III) vocabulary scores (n=20). Overall, individuals with schizophrenia produced fewer words than healthy controls, replicating past research (see Bokat and Goldberg, 2003). Words produced in the semantic fluency task by individuals with schizophrenia were, on average, earlier acquired and more typical of the category. In contrast, no differences in lexical characteristics emerged in the letter fluency task. The results are informative regarding how individuals with schizophrenia access their mental lexicons during the verbal fluency task. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Real-space observation of strong metal-support interaction: state-of-the-art and what's the next.
Shi, X Y; Zhang, W; Zhang, C; Zheng, W T; Chen, H; Qi, J G
2016-06-01
The real-space resolving of the encapsulated overlayer in the well-known model and industry catalysts, ascribed to the advent of dedicated transmission electron microscopy, enables us to probe novel nano/micro architecture chemistry for better application, revisiting our understanding of this key issue in heterogeneous catalysis. In this review, we summarize the latest progress of real-space observation of SMSI in several well-known systems mainly covered from the metal catalysts (mostly Pt) supported by the TiO2 , CeO2 and Fe3 O4 . As a comparison with the model catalyst Pt/Fe3 O4 , the industrial catalyst Cu/ZnO is also listed, followed with the suggested ongoing directions in the field. © 2015 The Authors Journal of Microscopy © 2015 Royal Microscopical Society.
Fine, Eric M; Delis, Dean C; Paul, Brianna M; Filoteo, J Vincent
2011-02-01
There has been an increasing interest within neuropsychology in comparing verbal fluency for different grammatical classes (e.g., verb generation vs. noun generation) in neurological populations, including Parkinson's disease (PD). However, to our knowledge, few studies have compared verbal fluency for common nouns and proper names in PD. Common nouns and proper names differ in terms of their semantic characteristics, as categories of common nouns are organized hierarchically based on semantics, while categories of proper nouns lack a well-defined semantic organization. In addition, there is accumulating evidence that the retrieval of these distinct grammatical classes are subserved by somewhat distinct neural systems. Given that verbal fluency deficits are among the first impairments to emerge in PD, and that such deficits are predictors of future cognitive decline, it is important to examine all aspects of verbal fluency in this population. For the current study, we compared the performance of a group of 32 nondemented PD patients with 32 healthy participants (HP) on verbal fluency tasks for common nouns (animals) and proper names (boys' first names). A significant interaction between verbal fluency task and diagnostic status emerged, as the PD group performed significantly worse on only the proper name fluency task. This finding may reflect the absence of well-defined semantic organization that structures the verbal search for first names, thus placing a greater onus on strategic or "executive" verbal retrieval processes.
Reading Fluency and College Readiness
ERIC Educational Resources Information Center
Rasinski, Timothy V.; Chang, Shu-Ching; Edmondson, Elizabeth; Nageldinger, James; Nigh, Jennifer; Remark, Linda; Kenney, Kristen Srsen; Walsh-Moorman, Elizabeth; Yildirim, Kasim; Nichols, William Dee; Paige, David D.; Rupley, William H.
2017-01-01
The Common Core State Standards suggest that an appropriate goal for secondary education is college and career readiness. Previous research has identified reading fluency as a critical component for proficient reading. One component of fluency is word recognition accuracy and automaticity. The present study attempted to determine the word…
A Comparison of Group-Oriented Contingencies for Addition Fluency
ERIC Educational Resources Information Center
Gross, Thomas J.; Duhon, Gary J.; Shutte, Greg; Rowland, Julie E.
2016-01-01
Math fact fluency is critical for understanding complex mathematics. Explicit timing interventions have shown promise for improving math fluency, and they may benefit from being paired with group-oriented contingencies. Further, investigations of independent and dependent group-oriented contingencies would help to identify their relative…
Oral Reading Fluency in Second Language Reading
ERIC Educational Resources Information Center
Jeon, Eun Hee
2012-01-01
This study investigated the role of oral reading fluency in second language reading. Two hundred and fifty-five high school students in South Korea were assessed on three oral reading fluency (ORF) variables and six other reading predictors. The relationship between ORF and other reading predictors was examined through an exploratory factor…
The Effect of Processing Fluency on Impressions of Familiarity and Liking
ERIC Educational Resources Information Center
Westerman, Deanne L.; Lanska, Meredith; Olds, Justin M.
2015-01-01
Processing fluency has been shown to have wide-ranging effects on disparate evaluative judgments, including judgments of liking and familiarity. One account of such effects is the hedonic marking hypothesis (Winkielman, Schwarz, Fazendeiro, & Reber, 2003), which posits that fluency is directly linked to affective preferences via a positive…
ERIC Educational Resources Information Center
Johnston, Lauren E.; Mercer, Sterett H.; Geres-Smith, Rhonda
2018-01-01
The purpose of this preliminary study was to determine whether incorporating vocabulary instruction in individual reading fluency interventions for English Language Learners (ELLs) would improve reading comprehension. Two vocabulary instructional procedures were contrasted with a fluency-building only condition in an alternating-treatments design…
Linguistic and Cultural Factors Associated with Phonemic Fluency Performance in Bilingual Hispanics
ERIC Educational Resources Information Center
Bennett, Jennifer
2012-01-01
Verbal fluency tasks are used extensively in clinical settings because of their sensitivity to a wide variety of disorders, including cognitive decline and dementia, and their usefulness in differential diagnoses. However, the effects of bilingualism on neuropsychological assessment, and verbal fluency in particular, are currently not completely…
Linguistic Skills and Speaking Fluency in a Second Language
ERIC Educational Resources Information Center
De Jong, Nivja H.; Steinel, Margarita P.; Florijn, Arjen; Schoonen, Rob; Hulstijn, Jan H.
2013-01-01
This study investigated how individual differences in linguistic knowledge and processing skills relate to individual differences in speaking fluency. Speakers of Dutch as a second language ("N" = 179) performed eight speaking tasks, from which several measures of fluency were derived such as measures for pausing, repairing, and speed…
Computational Fluency Performance Profile of High School Students with Mathematics Disabilities
ERIC Educational Resources Information Center
Calhoon, Mary Beth; Emerson, Robert Wall; Flores, Margaret; Houchins, David E.
2007-01-01
The purpose of this descriptive study was to develop a computational fluency performance profile of 224 high school (Grades 9-12) students with mathematics disabilities (MD). Computational fluency performance was examined by grade-level expectancy (Grades 2-6) and skill area (whole numbers: addition, subtraction, multiplication, division;…
Comparison of Animal, Action and Phonemic Fluency in Aphasia
ERIC Educational Resources Information Center
Faroqi-Shah, Yasmeen; Milman, Lisa
2018-01-01
Background: The ability to generate words that follow certain constraints, or verbal fluency, is a sensitive indicator of neurocognitive impairment, and is impacted by a variety of variables. Aims: To investigate the effect of post-stroke aphasia, elicitation category and linguistic variables on verbal fluency performance. Methods &…
Fluency Instruction. Research-Based Best Practices
ERIC Educational Resources Information Center
Rasinski, Timothy Ed.; Blachowicz, Camille Ed.; Lems, Kristin Ed.
2006-01-01
Because fluency instruction was identified, only recently, as a cornerstone literacy subject--it is still unfamiliar terrain for many teachers. This volume fills a crucial gap by offering a thorough, authoritative examination of what reading fluency is--and how it should be taught. Contributing authors, who include the field's leading authorities,…
Developing Mathematical Fluency: Comparing Exercises and Rich Tasks
ERIC Educational Resources Information Center
Foster, Colin
2018-01-01
Achieving fluency in important mathematical procedures is fundamental to students' mathematical development. The usual way to develop procedural fluency is to practise repetitive exercises, but is this the only effective way? This paper reports three quasi-experimental studies carried out in a total of 11 secondary schools involving altogether 528…
Considering the Context and Texts for Fluency: Performance, Readers Theater, and Poetry
ERIC Educational Resources Information Center
Young, Chase; Nageldinger, James
2014-01-01
This article describes the importance of teaching reading fluency and all of its components, including automaticity and prosody. The authors explain how teachers can create a context for reading fluency instruction by engaging students in reading performance activities. To support the instructional contexts, the authors suggest particular…
Concurrent Validity of the Test of Silent Word Reading Fluency
ERIC Educational Resources Information Center
Bell, Sherry Mee; McCallum, R. Steve; Burton, Bobbie; Gray, Rebecca; Windingstad, Sunny; Moore, Jessica
2006-01-01
Relationships between the Test of Silent Word Reading Fluency (TOSWRF; Mather, Hammill, Allen, & Roberts, 2004), a recently developed measure of fluency, and other operationalizations of reading, including subtests from the Comprehensive Test of Basic Skills (CTBS; 1996), and the Woodcock-Johnson-III Tests of Achievement, (WJ-III; Woodcock,…
Orthographic Learning in Dyslexic Spanish Children
ERIC Educational Resources Information Center
Suárez-Coalla, Paz; Ramos, Sara; Álvarez-Cañizo, Marta; Cuetos, Fernando
2014-01-01
Reading fluency is one of the basic processes of learning to read. Children begin to develop fluency when they are able to form orthographic representations of words, which provide direct, smooth, and fast reading. Dyslexic children of transparent orthographic systems are mainly characterized by poor reading fluency (Cuetos & Suárez-Coalla…
A Spectrographically Grounded Scale for Evaluating Reading Expressiveness
ERIC Educational Resources Information Center
Benjamin, Rebekah George; Schwanenflugel, Paula J.; Meisinger, Elizabeth B.; Groff, Carolyn; Kuhn, Melanie R.; Steiner, Lilly
2013-01-01
This study evaluated the validity of a new scale for assessing children's reading fluency skill called the Comprehensive Oral Reading Fluency Scale (CORFS). The CORFS consists of two subscales that capture key elements of the Kuhn, Schwanenflugel, and Meisinger (2010) definition of reading fluency: reading expression, reading rate, and accuracy.…
Wanzek, Jeanne; Roberts, Greg; Linan-Thompson, Sylvia; Vaughn, Sharon; Woodruff, Althea L.; Murray, Christy S.
2011-01-01
The current study examined the predictive validity of oral reading fluency measures across first, second, and third grades for two reading achievement measures at the end of third grade. Oral reading fluency measures were administered to students from first grade to third. The Texas Assessment of Knowledge and Skills and the Stanford Achievement Test were also administered in the third grade. Oral reading fluency was a reliable predictor of student success on both measures. Data suggest that greater student growth in oral reading fluency is needed through the grade levels to ensure high probabilities of success on the nationally normed measure, as compared to what is needed for the state-normed measure. Implications for practice and future research are discussed. PMID:21479152
Frontal and temporal lobe involvement on verbal fluency measures in amyotrophic lateral sclerosis.
Lepow, Lauren; Van Sweringen, James; Strutt, Adriana M; Jawaid, Ali; MacAdam, Claire; Harati, Yadollah; Schulz, Paul E; York, Michele K
2010-11-01
Amyotrophic lateral sclerosis (ALS) has been associated with changes in frontal and temporal lobe-mediated cognitive and behavioral functions. Verbal fluency, a sensitive measure to these changes, was utilized to investigate phonemic and semantic abilities in 49 ALS patients and 25 healthy controls (HCs). A subset of the ALS patients was classified as ALS-intact, ALS with mild cognitive impairments (ALS-mild), and ALS with fronto-temporal dementia (ALS-FTD) based on a comprehensive neuropsychological evaluation. Clustering and switching, the underlying component processes of verbal fluency, were analyzed using Troyer's (Troyer, Moscovitch, & Winocur, 1997) and Abwender's (Abwender, Swan, Bowerman, & Connolly, 2001) scoring systems. ALS patients exhibited decreased fluency versus HCs. For phonemic fluency, the intact ALS sample generated fewer clusters and more switches than the ALS-mild and ALS-FTD patients using both scoring systems. This suggests temporal involvement in ALS patients, with increasing frontal lobe involvement in patients with greater cognitive dysfunction. For semantic fluency, similar results were obtained with a greater emphasis on declines in clustering or increased temporal lobe dysfunction. These results suggest that verbal fluency measures identify frontal and temporal lobe involvement in the cognitive decline associated with ALS, particularly when the component processes are evaluated. The clinical utility of these scoring systems with ALS patients is also discussed.
Eichorn, Naomi; Marton, Klara; Schwartz, Richard G; Melara, Robert D; Pirutinsky, Steven
2016-06-01
The present study examined whether engaging working memory in a secondary task benefits speech fluency. Effects of dual-task conditions on speech fluency, rate, and errors were examined with respect to predictions derived from three related theoretical accounts of disfluencies. Nineteen adults who stutter and twenty adults who do not stutter participated in the study. All participants completed 2 baseline tasks: a continuous-speaking task and a working-memory (WM) task involving manipulations of domain, load, and interstimulus interval. In the dual-task portion of the experiment, participants simultaneously performed the speaking task with each unique combination of WM conditions. All speakers showed similar fluency benefits and decrements in WM accuracy as a result of dual-task conditions. Fluency effects were specific to atypical forms of disfluency and were comparable across WM-task manipulations. Changes in fluency were accompanied by reductions in speaking rate but not by corresponding changes in overt errors. Findings suggest that WM contributes to disfluencies regardless of stuttering status and that engaging WM resources while speaking enhances fluency. Further research is needed to verify the cognitive mechanism involved in this effect and to determine how these findings can best inform clinical intervention.
Milhau, Audrey; Brouillet, Thibaut; Brouillet, Denis
2015-01-01
According to the body specificity hypothesis, the way we interact with our environment participates in our conceptualization of concepts and word meanings. For instance, valence is associated to horizontal space because of the motor fluency by which one acts with one's dominant hand. We propose that the decisive factor in the compatibility effects between valence and lateral actions is the interaction between the fluency of response movement and the situational constraints of the task. In a valence judgement task with positive and negative words, right-handers (Experiment 1) and left-handers (Experiment 2) responded with lateralized actions of either their dominant or their nondominant hand. To do so, we used a response device that was either congruent or noncongruent with the fluency of the response hand. Results highlighted that when the response device was congruent with the fluency of the responding hand, response times to positive evaluations were shorter than those to negative evaluations. Conversely, when the response device was noncongruent with the fluency of the responding hand, we observed faster responses for negative evaluations than for positive evaluations. Furthermore, we obtained similar patterns for right- and left-handers, supporting the idea that compatibility effects are driven by the situated fluency of the responding hand.
Designing persuasive health materials using processing fluency: a literature review.
Okuhara, Tsuyoshi; Ishikawa, Hirono; Okada, Masahumi; Kato, Mio; Kiuchi, Takahiro
2017-06-08
Health materials to promote health behaviors should be readable and generate favorable evaluations of the message. Processing fluency (the subjective experience of ease with which people process information) has been increasingly studied over the past decade. In this review, we explore effects and instantiations of processing fluency and discuss the implications for designing effective health materials. We searched seven online databases using "processing fluency" as the key word. In addition, we gathered relevant publications using reference snowballing. We included published records that were written in English and applicable to the design of health materials. We found 40 articles that were appropriate for inclusion. Various instantiations of fluency have a uniform effect on human judgment: fluently processed stimuli generate positive judgments (e.g., liking, confidence). Processing fluency is used to predict the effort needed for a given task; accordingly, it has an impact on willingness to undertake the task. Physical perceptual, lexical, syntactic, phonological, retrieval, and imagery fluency were found to be particularly relevant to the design of health materials. Health-care professionals should consider the use of a perceptually fluent design, plain language, numeracy with an appropriate degree of precision, a limited number of key points, and concrete descriptions that make recipients imagine healthy behavior. Such fluently processed materials that are easy to read and understand have enhanced perspicuity and persuasiveness.
Haley, Katarina L.
2015-01-01
Purpose To study the effects of masked auditory feedback (MAF) on speech fluency in adults with aphasia and/or apraxia of speech (APH/AOS). We hypothesized that adults with AOS would increase speech fluency when speaking with noise. Altered auditory feedback (AAF; i.e., delayed/frequency-shifted feedback) was included as a control condition not expected to improve speech fluency. Method Ten participants with APH/AOS and 10 neurologically healthy (NH) participants were studied under both feedback conditions. To allow examination of individual responses, we used an ABACA design. Effects were examined on syllable rate, disfluency duration, and vocal intensity. Results Seven of 10 APH/AOS participants increased fluency with masking by increasing rate, decreasing disfluency duration, or both. In contrast, none of the NH participants increased speaking rate with MAF. In the AAF condition, only 1 APH/AOS participant increased fluency. Four APH/AOS participants and 8 NH participants slowed their rate with AAF. Conclusions Speaking with MAF appears to increase fluency in a subset of individuals with APH/AOS, indicating that overreliance on auditory feedback monitoring may contribute to their disorder presentation. The distinction between responders and nonresponders was not linked to AOS diagnosis, so additional work is needed to develop hypotheses for candidacy and underlying control mechanisms. PMID:26363508
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kundu, Sanjoy, E-mail: sanjoy_kundu40@hotmail.com; Modabber, Milad; You, John M.
2011-10-15
Purpose: To assess the safety and effectiveness of a polytetrafluoroethylene (PTFE) encapsulated nitinol stents (Bard Peripheral Vascular, Tempe, AZ) for treatment of hemodialysis-related central venous occlusions. Materials and Methods: Study design was a single-center nonrandomized retrospective cohort of patients from May 2004 to August 2009 for a total of 64 months. There were 14 patients (mean age 60 years, range 50-83 years; 13 male, 1 female). All patients had autogenous fistulas. All 14 patients had central venous occlusions and presented with clinical symptoms of the following: extremity swelling (14%, 2 of 14), extremity and face swelling (72%, 10 of 14),more » and face swelling/edema (14%, 2 of 14). There was evidence of access dysfunction with decreased access flow in 36% (5 of 14) patients. There were prior interventions or previous line placement at the site of the central venous lesion in all 14 patients. Results were assessed by recurrence of clinical symptoms and function of the access circuit (National Kidney Foundation recommended criteria). Results: Sixteen consecutive straight stent grafts were implanted in 14 patients. Average treated lesion length was 5.0 cm (range, 0.9-7 cm). All 14 patients had complete central venous occlusion (100% stenosis). The central venous occlusions were located as follows: right subclavian and brachiocephalic vein (21%, 3 of 14), right brachiocephalic vein (36%, 5 of 14), left brachiocephalic vein (36%, 5 of 14), and bilateral brachiocephalic vein (7%, 1 of 14). A total of 16 PTFE stent grafts were placed. Ten- or 12-mm-diameter PTFE stent grafts were placed. The average stent length was 6.1 cm (range, 4-8 cm). Technical (deployment), anatomic (<30% residual stenosis), clinical (resolution of symptoms), and hemodynamic (resolution of access dysfunction) success were 100%. At 3, 6, and 9 months, primary patency of the treated area and access circuit were 100% (14 of 14). Conclusions: This PTFE encapsulated stent graft demonstrates encouraging intermediate-term patency results for central vein occlusions. Further prospective studies with long-term assessment and larger patient populations will be required.« less
Gupta, Rajesh; Reddy, D Nageshwar
2011-09-01
Endoscopic stenting is an effective treatment option in the management of both benign biliary strictures and pancreatic ductal strictures. Plastic stents and self-expandable metal stents have been used with variable success for the management of both benign biliary strictures and pancreatic ductal strictures caused by chronic pancreatitis. Fully covered self-expandable metal stents of improved design represent a major technological advance which has added to the endoscopic armamentarium. Both multiple plastic stents and covered self-expandable metal stents have shown promising results. However, data to support the use of self-expandable metal stents over multiple plastic stents or vice versa are still lacking.
NASA Astrophysics Data System (ADS)
Zhu, Jianxiong; Chen, Cong; Guo, Xiaoyu
2018-04-01
We report a suspended polytetrafluoroethylene (PTFE) nanostructure electret film in dual variable cavities for a self-powered micro-shock sensing application. The prototype contained series variable air cavities, a suspended nanostructure PTFE electret film and independent electrode films. The charges on the suspended nanostructure PTFE electret film provided the electrostatic field around the electret film in the series variable air cavities. When the reported device was driven by a micro-shock pressure, the inducted electrostatic charges on both the top and bottom electrodes would vary as the micro-shock pressing or releasing. Experimental results showed that the maximum of a short-circuit current density (J sc ) and an open-circuit voltage (V oc ) reached 3 ± 0.1 nA cm‑2 and 3.6 ± 0.1 V, respectively. It was found that the parameter J sc was more advantageous in identifying stronger shocks (parameter acceleration a bigger than 0.1 m s‑2), whereas the parameter V oc was more sensitive for weaker shocks, such as acceleration a smaller than 0.1 m s‑2. Moreover, finger continuous micro-shock pressure taps application was used to demonstrate the mechanical energy conversion performance with 4.5 ± 0.2 V open-circuit voltages. The research on the nanostructure electret PTFE film in series dual variable air cavities not only gave us a fresh idea about the principle and design of the shocking sensor, but also provided an easy fabrication and a low cost shocking sensor for the Internet of Things (IoT) systems.
Reflectivity Spectra for Commonly Used Reflectors
NASA Astrophysics Data System (ADS)
Janecek, Martin
2012-06-01
Monte Carlo simulations play an important role in developing and evaluating the performance of radiation detection systems. To accurately model a reflector in an optical Monte Carlo simulation, the reflector's spectral response has to be known. We have measured the reflection coefficient for many commonly used reflectors for wavelengths from 250 nm to 800 nm. The reflectors were also screened for fluorescence and angular distribution changes with wavelength. The reflectors examined in this work include several polytetrafluoroethylene (PTFE) reflectors, Spectralon, GORE diffuse reflector, titanium dioxide paint, magnesium oxide, nitrocellulose filter paper, Tyvek paper, Lumirror, Melinex, ESR films, and aluminum foil. All PTFE films exhibited decreasing reflectivity with longer wavelengths due to transmission. To achieve >;0.95 reflectivity in the 380 to 500 nm range, the PTFE films have to be at least 0.5 mm thick-nitrocellulose is a good alternative if a thin diffuse reflector is needed. Several of the reflectors have sharp declines in reflectivity below a cut-off wavelength, including TiO2 (420 nm), ESR film (395 nm), nitrocellulose (330 nm), Lumirror (325 nm), and Melinex (325 nm). PTFE-like reflectors were the only examined reflectors that had reflectivity above 0.90 for wavelengths below 300 nm. Lumirror, Melinex, and ESR film exhibited fluorescence. Lumirror and Melinex are excited by wavelengths between 320 and 420 nm and have their emission peaks located at 440 nm, while ESR film is excited by wavelengths below 400 nm and the emission peak is located at 430 nm. Lumirror and Melinex also exhibited changing angular distributions with wavelength.
Magnetic strength and corrosion of rare earth magnets.
Ahmad, Khalid A; Drummond, James L; Graber, Thomas; BeGole, Ellen
2006-09-01
Rare earth magnets have been used in orthodontics, but their corrosion tendency in the oral cavity limits long-term clinical application. The aim of this project was to evaluate several; magnet coatings and their effects on magnetic flux density. A total of 60 neodymium-iron-boron magnets divided into 6 equal groups--polytetrafluoroethylene-coated (PTFE), parylene-coated, and noncoated--were subjected to 4 weeks of aging in saline solution, ball milling, and corrosion testing. A significant decrease in magnet flux density was recorded after applying a protective layer of parylene, whereas a slight decrease was found after applying a protective layer of PTFE. After 4 weeks of aging, the coated magnets were superior to the noncoated magnets in retaining magnetism. The corrosion-behavior test showed no significant difference between the 2 types of coated magnets, and considerable amounts of iron-leached ions were seen in all groups. Throughout the processes of coating, soaking, ball milling, and corrosion testing, PTFE was a better coating material than parylene for preserving magnet flux density. However, corrosion testing showed significant metal leaching in all groups.
Investigation of PTFE transfer films by infrared emission spectroscopy and phase-locked ellipsometry
NASA Technical Reports Server (NTRS)
Lauer, James L.; Bunting, Bruce G.; Jones, William R., Jr.
1987-01-01
When a PTFE sheet was rubbed unidirectionally over a smooth surface of stainless steel an essentially monomolecular transfer film was formed. By ellipsometric and emission infrared spectroscopic techniques it was shown that the film was 10 to 15 A thick and birefringent. From the intensity differences of infrared bands obtained with a polarizer passing radiation polarized in mutually perpendicular planes, it was possible to deduce transfer film orientation with the direction of rubbing. After standing in air for several weeks the transfer films apparently increased in thickness by as much as threefold. At the same time both the index of refraction and the absorption index decreased. Examination of the surfaces by optical and electron microscopies showed that the films had become porous and flaky. These observations were consistent with previous tribological measurements. The coefficients of friction decreased with the formation of the transfer film but increased again as the film developed breaks. The applicability of the ellipsometric and polarized infrared emission techniques to the identification of monomolecular tribological transfer films of polymers such as PTFE has been demonstrated.
Zhang, Chengxi; Luan, Weiling; Yin, Yuhang; Yang, Fuqian
2017-01-01
Colloidal perovskite nanocrystals comprised of all inorganic cesium lead halide (CsPbX 3 , X = Cl, Br, I or a mixture thereof) have potential as optical gain materials due to their high luminescence efficiency. In this work, cesium lead halide nanocrystals are continuously synthesized via a microreactor system consisting of poly(tetrafluoroethylene) (PTFE) capillaries. The synthesized nanocrystals possess excellent optical properties, including a full width at half maximum of 19-35 nm, high fluorescence quantum yield of 47.8-90.55%, and photoluminescence emission in the range of 450-700 nm. For the same precursor concentrations, the photoluminescence emission peak generally increases with increasing reaction temperature, revealing a controllable temperature effect on the photoluminescence characteristics of the synthesized nanocrystals. For quantum dots synthesized with a Br/I ratio of 1:3, a slight blue shift was observed for reaction temperatures greater than 100 °C. This PTFE-based microreactor system provides the unique capability of continuously synthesizing high-quality perovskite nanocrystals that emit over the full visible spectrum with applications ranging from displays and optoelectronic devices.
Zhang, Chengxi; Yin, Yuhang
2017-01-01
Colloidal perovskite nanocrystals comprised of all inorganic cesium lead halide (CsPbX3, X = Cl, Br, I or a mixture thereof) have potential as optical gain materials due to their high luminescence efficiency. In this work, cesium lead halide nanocrystals are continuously synthesized via a microreactor system consisting of poly(tetrafluoroethylene) (PTFE) capillaries. The synthesized nanocrystals possess excellent optical properties, including a full width at half maximum of 19–35 nm, high fluorescence quantum yield of 47.8–90.55%, and photoluminescence emission in the range of 450–700 nm. For the same precursor concentrations, the photoluminescence emission peak generally increases with increasing reaction temperature, revealing a controllable temperature effect on the photoluminescence characteristics of the synthesized nanocrystals. For quantum dots synthesized with a Br/I ratio of 1:3, a slight blue shift was observed for reaction temperatures greater than 100 °C. This PTFE-based microreactor system provides the unique capability of continuously synthesizing high-quality perovskite nanocrystals that emit over the full visible spectrum with applications ranging from displays and optoelectronic devices. PMID:29259867
Explosively driven low-density foams and powders
Viecelli, James A [Orinda, CA; Wood, Lowell L [Simi Valley, CA; Ishikawa, Muriel Y [Livermore, CA; Nuckolls, John H [Danville, CA; Pagoria, Phillip F [Livermore, CA
2010-05-04
Hollow RX-08HD cylindrical charges were loaded with boron and PTFE, in the form of low-bulk density powders or powders dispersed in a rigid foam matrix. Each charge was initiated by a Comp B booster at one end, producing a detonation wave propagating down the length of the cylinder, crushing the foam or bulk powder and collapsing the void spaces. The PdV work done in crushing the material heated it to high temperatures, expelling it in a high velocity fluid jet. In the case of boron particles supported in foam, framing camera photos, temperature measurements, and aluminum witness plates suggest that the boron was completely vaporized by the crush wave and that the boron vapor turbulently mixed with and burned in the surrounding air. In the case of PTFE powder, X-ray photoelectron spectroscopy of residues recovered from fragments of a granite target slab suggest that heating was sufficient to dissociate the PTFE to carbon vapor and molecular fluorine which reacted with the quartz and aluminum silicates in the granite to form aluminum oxide and mineral fluoride compounds.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ionita, G.; Stefanescu, I.
The nature and performance of our patented catalysts, with platinum on carbon and polytetrafluorethylene [Pt/C/PTFE] and platinum on styrenedivynilbenzene and polystyrene [Pt/STB/PS], used in a water-hydrogen isotope exchange process are presented. The behaviour of the two catalysts in tritiated water was tested by determining their physical and structural characteristics as well as the catalytic activity before and after immersion in tritiated water. The test results emphasized that the two catalysts are highly active in the hydrogen - water vapor (H{sub 2(g)}-H{sub 2}O{sub (v)}) isotopic exchange and highly stable to tritium radiation. It was discovered that Pt/SDB/PS catalyst proved to bemore » quite unstable in the hydrogen- water vapor - water (H{sub 2(g)}-H{sub 2}O{sub (v)}-H{sub 2}O{sub (1)}) isotopic exchange, while the Pt/C/PTFE catalyst was highly stable. Thus, the Pt/C/PTFE catalyst was chosen for hydrogen isotope separation by liquid hydrogen cryogenic distillation combined with water - hydrogen isotopic exchange in a demonstration scale plant. 5 refs., 8 figs., 2 tabs.« less
Fabrication of transparent superhydrophobic polytetrafluoroethylene coating
NASA Astrophysics Data System (ADS)
Alawajji, Raad A.; Kannarpady, Ganesh K.; Biris, Alexandru S.
2018-06-01
Polytetrafluoroethylene (PTFE) thin films were successfully deposited on glass substrates using pulsed laser deposition, with deposition times ranging from 30 to 120 minutes (min). The surface roughness of the films increased as deposition time increased, with micro/nanoscale roughness developing when deposition time increased over 60 min. This roughness made the surface superhydrophobic, having a contact angle of about 151.6°±1. UV-vis spectroscopic analysis of the PTFE films revealed that they were highly transparent, up to ∼90% in visible and near-infrared ranges. Furthermore, when the deposition time was increased-which increased the films' thickness-the films were able to absorb 80-90% of ultraviolet light in the wavelength range <300 nm. The researchers used an x-ray photoelectron spectrometer to find the chemical and elemental composition of the films' surfaces. Atomic force microscopy was used to determine the effect of surface roughness on the films' hydrophobicity. The fabricated superhydrophobic films have many potential practical uses, from self-cleaning materials to solar cell panel coatings. Additionally, the low dielectric properties of PTFE make the films' ideal for communication antenna coatings and similar applications.
Xia, Wei; Peter, Christian; Weng, Junhui; Zhang, Jian; Kliem, Herbert; Jiang, Yulong; Zhu, Guodong
2017-04-05
Ferroelectric polymer based devices exhibit great potentials in low-cost and flexible electronics. To meet the requirements of both low voltage operation and low energy consumption, thickness of ferroelectric polymer films is usually required to be less than, for example, 100 nm. However, decrease of film thickness is also accompanied by the degradation of both crystallinity and ferroelectricity and also the increase of current leakage, which surely degrades device performance. Here we report one epitaxy method based on removable poly(tetrafluoroethylene) (PTFE) templates for high-quality fabrication of ordered ferroelectric polymer thin films. Experimental results indicate that such epitaxially grown ferroelectric polymer films exhibit well improved crystallinity, reduced current leakage and good resistance to electrical breakdown, implying their applications in high-performance and low voltage operated ferroelectric devices. On the basis of this removable PTFE template method, we fabricated organic semiconducting/ferroelectric blend resistive films which presented record electrical performance with operation voltage as low as 5 V and ON/OFF ratio up to 10 5 .
NASA Astrophysics Data System (ADS)
Kim, Jihoon; Lee, Yongkyu; Jeon, Jae-Deok; Kwak, Seung-Yeop
2018-04-01
A series of ion-exchange membranes for vanadium redox flow batteries (VRBs) are prepared by filling the pores of a poly(tetrafluoroethylene) (PTFE) substrate with sulfonated poly(ether ether ketone) (SPEEK) and microporous Engelhard titanosilicate-10 (ETS-10). The effects of ETS-10 incorporation and PTFE reinforcement on membrane properties and VRB single-cell performance are investigated using various characterization tools. The results show that these composite membranes exhibit improved mechanical properties and reduced vanadium-ion permeabilities owing to the interactions between ETS-10 and SPEEK, the suppressed swelling of PTFE, and the unique ETS-10 framework. The composite membrane with 3 wt% ETS-10 (referred to as "SE3/P") exhibits the best membrane properties and highest ion selectivity. The VRB system with the SE3/P membrane exhibits higher cell capacity, higher cell efficiency, and lower capacity decay than that with a Nafion membrane. These results indicate that this composite membrane has potential as an alternative to Nafion in VRB systems.
NASA Astrophysics Data System (ADS)
Resnyansky, A. D.; McDonald, S. A.; Withers, P. J.; Bourne, N. K.; Millett, J. C. F.; Brown, E. N.; Rae, P. J.
2014-05-01
The current work presents Taylor impact experiments interrogating the effect of dynamic, high-pressure loading on polytetrafluoroethylene (PTFE). In particular, X-ray microtomography has been used to characterise the damage imparted to cylindrical samples due to impact at different velocities. Distinct regions of deformation are present and controlled by fracture within the polymer, with the extent of the deformed region and increasing propagation of fractures from the impact face showing a clear trend with increasing impact velocity. A two-phase rate sensitive strength model is implemented in the CTH hydrocode and used for simulation of the problem. The high-pressure phase transition of PTFE into Phase III within the crystalline domains from the polymer at normal conditions is managed by suitable phase transition kinetics within the model. The experimental observations are discussed with respect to the multi-phase model hydrocode predictions of the shock response from Taylor impact simulations. The damage and its progress are shown to correlate well with the onset of the phase transition and its evolution following the impact velocity increase.
Text-fading based training leads to transfer effects on children's sentence reading fluency
Nagler, Telse; Korinth, Sebastian P.; Linkersdörfer, Janosch; Lonnemann, Jan; Rump, Björn; Hasselhorn, Marcus; Lindberg, Sven
2015-01-01
Previous studies used a text-fading procedure as a training tool with the goal to increase silent reading fluency (i.e., proficient reading rate and comprehension). In recently published studies, this procedure resulted in lasting reading enhancements for adult and adolescent research samples. However, studies working with children reported mixed results. While reading rate improvements were observable for Dutch reading children in a text-fading training study, reading fluency improvements in standardized reading tests post-training attributable to the fading manipulation were not detectable. These results raise the question of whether text-fading training is not effective for children or whether research design issues have concealed possible transfer effects. Hence, the present study sought to investigate possible transfer effects resulting from a text-fading based reading training program, using a modified research design. Over a period of 3 weeks, two groups of German third-graders read sentences either with an adaptive text-fading procedure or at their self-paced reading rate. A standardized test measuring reading fluency at the word, sentence, and text level was conducted pre- and post-training. Text level reading fluency improved for both groups equally. Post-training gains at the word level were found for the text-fading group, however, no significant interaction between groups was revealed for word reading fluency. Sentence level reading fluency gains were found for the text-fading group, which significantly differed from the group of children reading at their self-paced reading routine. These findings provide evidence for the efficacy of text-fading as a training method for sentence reading fluency improvement also for children. PMID:25713554
Verbal fluency in bipolar disorders: A systematic review and meta-analysis.
Raucher-Chéné, Delphine; Achim, Amélie M; Kaladjian, Arthur; Besche-Richard, Chrystel
2017-01-01
One of the main features of bipolar disorder (BD), besides mood dysregulation, is an alteration of the structure of language. Bipolar patients present changes in semantic contents, impaired verbal associations, abnormal prosody and abnormal speed of language highlighted with various experimental tasks. Verbal fluency tasks are widely used to assess the abilities of bipolar patients to retrieve and produce verbal material from the lexico-semantic memory. Studies using these tasks have however yielded discrepant results. The aim of this study was thus to determine the extent of the verbal fluency impairment in BD patients and to evaluate if the deficits are affected by the type of task or by mood states. A systematic literature search was conducted in MEDLINE, EBSCOHost and Google Scholar and relevant data were submitted to a meta-analysis. Thirty-nine studies were retained providing data for 52 independent groups of BD patients. The overall meta-analysis revealed a moderate verbal fluency impairment in BD compared to healthy controls (effect size d=0.61). Comparisons between mood states showed significant differences only between euthymic and manic patients and only on category fluency performances. This review is limited by the heterogeneity between studies for the characteristics of BD populations. Also, few of the retained studies examined depressive or mixed episodes. This work confirms that BD patients present with moderate verbal fluency impairments, and underlines the specific effect of mood state on category fluency. This emphasizes the need to distinguish semantic from phonological processes in verbal fluency assessments in BD. Copyright © 2016 Elsevier B.V. All rights reserved.
Right hemisphere structures predict poststroke speech fluency.
Pani, Ethan; Zheng, Xin; Wang, Jasmine; Norton, Andrea; Schlaug, Gottfried
2016-04-26
We sought to determine via a cross-sectional study the contribution of (1) the right hemisphere's speech-relevant white matter regions and (2) interhemispheric connectivity to speech fluency in the chronic phase of left hemisphere stroke with aphasia. Fractional anisotropy (FA) of white matter regions underlying the right middle temporal gyrus (MTG), precentral gyrus (PreCG), pars opercularis (IFGop) and triangularis (IFGtri) of the inferior frontal gyrus, and the corpus callosum (CC) was correlated with speech fluency measures. A region within the superior parietal lobule (SPL) was examined as a control. FA values of regions that significantly predicted speech measures were compared with FA values from healthy age- and sex-matched controls. FA values for the right MTG, PreCG, and IFGop significantly predicted speech fluency, but FA values of the IFGtri and SPL did not. A multiple regression showed that combining FA of the significant right hemisphere regions with the lesion load of the left arcuate fasciculus-a previously identified biomarker of poststroke speech fluency-provided the best model for predicting speech fluency. FA of CC fibers connecting left and right supplementary motor areas (SMA) was also correlated with speech fluency. FA of the right IFGop and PreCG was significantly higher in patients than controls, while FA of a whole CC region of interest (ROI) and the CC-SMA ROI was significantly lower in patients. Right hemisphere white matter integrity is related to speech fluency measures in patients with chronic aphasia. This may indicate premorbid anatomical variability beneficial for recovery or be the result of poststroke remodeling. © 2016 American Academy of Neurology.
Contact angles and wettability of ionic liquids on polar and non-polar surfaces†
Sousa, Filipa L.; Silva, Nuno J. O.; Lopes-da-Silva, José A.; Coutinho, João A. P.; Freire, Mara G.
2016-01-01
Many applications involving ionic liquids (ILs) require the knowledge of their interfacial behaviour, such as wettability and adhesion. In this context, herein, two approaches were combined aiming at understanding the impact of the IL chemical structures on their wettability on both polar and non-polar surfaces, namely: (i) the experimental determination of the contact angles of a broad range of ILs (covering a wide number of anions of variable polarity, cations, and cation alkyl side chain lengths) on polar and non-polar solid substrates (glass, Al-plate, and poly-(tetrafluoroethylene) (PTFE)); and (ii) the correlation of the experimental contact angles with the cation–anion pair interaction energies generated by the Conductor-like Screening Model for Real Solvents (COSMO-RS). The combined results reveal that the hydrogen-bond basicity of ILs, and thus the IL anion, plays a major role through their wettability on both polar and non-polar surfaces. The increase of the IL hydrogen-bond accepting ability leads to an improved wettability of more polar surfaces (lower contact angles) while the opposite trend is observed on non-polar surfaces. The cation nature and alkyl side chain lengths have however a smaller impact on the wetting ability of ILs. Linear correlations were found between the experimental contact angles and the cation–anion hydrogen-bonding and cation ring energies, estimated using COSMO-RS, suggesting that these features primarily control the wetting ability of ILs. Furthermore, two-descriptor correlations are proposed here to predict the contact angles of a wide variety of ILs on glass, Al-plate, and PTFE surfaces. A new extended list is provided for the contact angles of ILs on three surfaces, which can be used as a priori information to choose appropriate ILs before a given application. PMID:26554705
Contact angles and wettability of ionic liquids on polar and non-polar surfaces.
Pereira, Matheus M; Kurnia, Kiki A; Sousa, Filipa L; Silva, Nuno J O; Lopes-da-Silva, José A; Coutinho, João A P; Freire, Mara G
2015-12-21
Many applications involving ionic liquids (ILs) require the knowledge of their interfacial behaviour, such as wettability and adhesion. In this context, herein, two approaches were combined aiming at understanding the impact of the IL chemical structures on their wettability on both polar and non-polar surfaces, namely: (i) the experimental determination of the contact angles of a broad range of ILs (covering a wide number of anions of variable polarity, cations, and cation alkyl side chain lengths) on polar and non-polar solid substrates (glass, Al-plate, and poly-(tetrafluoroethylene) (PTFE)); and (ii) the correlation of the experimental contact angles with the cation-anion pair interaction energies generated by the Conductor-like Screening Model for Real Solvents (COSMO-RS). The combined results reveal that the hydrogen-bond basicity of ILs, and thus the IL anion, plays a major role through their wettability on both polar and non-polar surfaces. The increase of the IL hydrogen-bond accepting ability leads to an improved wettability of more polar surfaces (lower contact angles) while the opposite trend is observed on non-polar surfaces. The cation nature and alkyl side chain lengths have however a smaller impact on the wetting ability of ILs. Linear correlations were found between the experimental contact angles and the cation-anion hydrogen-bonding and cation ring energies, estimated using COSMO-RS, suggesting that these features primarily control the wetting ability of ILs. Furthermore, two-descriptor correlations are proposed here to predict the contact angles of a wide variety of ILs on glass, Al-plate, and PTFE surfaces. A new extended list is provided for the contact angles of ILs on three surfaces, which can be used as a priori information to choose appropriate ILs before a given application.
Berthod, Laurence; Roberts, Gary; Whitley, David C; Sharpe, Alan; Mills, Graham A
2014-12-15
The partitioning of pharmaceuticals in the environment can be assessed by measuring their adsorption coefficients (Kd) between aqueous and solid phases. Measuring this coefficient in sewage sludge gives an indication of their partitioning behaviour in a wastewater treatment plant and hence contributes to an understanding of their subsequent fate. The regulatory approved method for measuring Kd in sewage sludge is the US Environmental Protection Agency's Office of Prevention, Pesticides and Toxic Substances (OPPTS) guideline 835.1110, which is labour intensive and time consuming. We describe an alternative method for measuring the Kd of pharmaceuticals in sewage sludge using a modified solid-phase extraction (SPE) technique. SPE cartridges were packed at different sludge/PTFE ratios (0.4, 6.0, 24.0 and 40.0% w/w sludge) and eluted with phosphate buffer at pH 7.4. The approach was tested initially using three pharmaceuticals (clofibric acid, diclofenac and oxytetracycline) that covered a range of Kd values. Subsequently, the sorption behaviour of ten further pharmaceuticals with varying physico-chemical properties was evaluated. Results from the SPE method were comparable to those of the OPPTS test, with a correlation coefficient of 0.93 between the two approaches. SPE cartridges packed with sludge and PTFE were stable for up to one year; use within one month reduced variability in measurements (to a maximum of 0.6 log units). The SPE method is low-cost, easy to use and enables the rapid measurement of Kd values for a large number of chemicals. It can be used as an alternative to the more laborious full OPPTS test in environmental fate studies and risk assessments. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.
Berthod, Laurence; Roberts, Gary; Whitley, David C.; Sharpe, Alan; Mills, Graham A.
2014-01-01
The partitioning of pharmaceuticals in the environment can be assessed by measuring their adsorption coefficients (Kd) between aqueous and solid phases. Measuring this coefficient in sewage sludge gives an indication of their partitioning behaviour in a wastewater treatment plant and hence contributes to an understanding of their subsequent fate. The regulatory approved method for measuring Kd in sewage sludge is the US Environmental Protection Agency's Office of Prevention, Pesticides and Toxic Substances (OPPTS) guideline 835.1110, which is labour intensive and time consuming. We describe an alternative method for measuring the Kd of pharmaceuticals in sewage sludge using a modified solid-phase extraction (SPE) technique. SPE cartridges were packed at different sludge/PTFE ratios (0.4, 6.0, 24.0 and 40.0% w/w sludge) and eluted with phosphate buffer at pH 7.4. The approach was tested initially using three pharmaceuticals (clofibric acid, diclofenac and oxytetracycline) that covered a range of Kd values. Subsequently, the sorption behaviour of ten further pharmaceuticals with varying physico-chemical properties was evaluated. Results from the SPE method were comparable to those of the OPPTS test, with a correlation coefficient of 0.93 between the two approaches. SPE cartridges packed with sludge and PTFE were stable for up to one year; use within one month reduced variability in measurements (to a maximum of 0.6 log units). The SPE method is low-cost, easy to use and enables the rapid measurement of Kd values for a large number of chemicals. It can be used as an alternative to the more laborious full OPPTS test in environmental fate studies and risk assessments. PMID:25299795
Strategic Key Word Instruction: Increasing Fluency in Connected Expository Text
ERIC Educational Resources Information Center
Coulter, Gail; Lambert, Michael C.
2015-01-01
The effects of preteaching key words on fluency in connected text were examined with three third-grade general education participants. Researchers used a multiple base-line design (i.e., Baseline and Wordlist Intervention) and found that preteaching increased fluency in connected text written above the participant's instructional level of reading…
Instructor Fluency Leads to Higher Confidence in Learning, but Not Better Learning
ERIC Educational Resources Information Center
Toftness, Alexander R.; Carpenter, Shana K.; Geller, Jason; Lauber, Sierra; Johnson, Madeline; Armstrong, Patrick I.
2018-01-01
Students' judgements of their own learning often exceed their knowledge on a given topic. One source of this pervasive overconfidence is fluency, the perceived ease with which information is acquired. Though effects of fluency on metacognitive judgments have been explored by manipulating relatively simple stimuli such as font style, few studies…
Training for Fluency and Generalization of Math Facts Using Technology
ERIC Educational Resources Information Center
Musti-Rao, Shobana; Lynch, Tom Liam; Plati, Erin
2015-01-01
As American students struggle with basic mathematical skills, the importance of math fact fluency has gained the attention of educators and researchers. Generalization of math fact fluency is also important for the transfer of skills to other settings and formats, assisting students in the completion of more varied and complicated math tasks. This…
Embodied Memory Judgments: A Case of Motor Fluency
ERIC Educational Resources Information Center
Yang, Shu-Ju; Gallo, David A.; Beilock, Sian L.
2009-01-01
It is well known that perceptual and conceptual fluency can influence episodic memory judgments. Here, the authors asked whether fluency arising from the motor system also impacts recognition memory. Past research has shown that the perception of letters automatically activates motor programs of typing actions in skilled typists. In this study,…
Using Performance Methods to Enhance Students' Reading Fluency
ERIC Educational Resources Information Center
Young, Chase; Valadez, Corinne; Gandara, Cori
2016-01-01
The quasi-experimental study examined the effects of pairing Rock and Read with Readers Theater and only Rock and Read on second grade students' reading fluency scores. The 51 subjects were pre- and post-tested on five different reading fluency measures. A series of 3 × 2 repeated measures ANOVAs revealed statistically significant interaction…
Keep Up the Good Work! Part III: Using Multimedia To Build Reading Fluency and Enjoyment.
ERIC Educational Resources Information Center
Glasgow, Jacqueline N.
1997-01-01
Discusses building fluency in reading and writing and teaching students to read and write for pleasure. Highlights include multimedia storyboards; bilingual instruction; writing programs for building fluency; CD-ROM storyboards; student-created storyboards; and an annotated bibliography of CD-ROM storyboards, poetry collections, and composing…
Using Computer-Assisted Instruction to Build Math Fact Fluency: An Implementation Guide
ERIC Educational Resources Information Center
Hawkins, Renee O.; Collins, Tai; Hernan, Colleen; Flowers, Emily
2017-01-01
Research findings support the use of computer-assisted instruction (CAI) as a curriculum supplement for improving math skills, including math fact fluency. There are a number of websites and mobile applications (i.e., apps) designed to build students' math fact fluency, but the options can become overwhelming. This article provides implementation…
A Strategic Necessity: Building Senior Leadership's Fluency in Digital Technology
ERIC Educational Resources Information Center
Kolomitz, Kara; Cabellon, Edmund T.
2016-01-01
This chapter describes the opportunity for senior student affairs officers (SSAOs) to develop an increased digital fluency to meet the needs of various constituencies in the digital age. The authors explore what a digital fluency is, how it might impact SSAOs' leadership potential, and the benefits for their respective divisions.
Fluency Training. NetNews . Volume 4, Number 5
ERIC Educational Resources Information Center
LDA of Minnesota, 2004
2004-01-01
In the past, researchers believed that reading fluency developed as a result of good word recognition skills; however, it is now believed that fluency must be explicitly taught and practiced orally in order to develop. Readers who are not fluent in reading will be less motivated to practice, have more difficulty learning academic content, and…
When Two Sources of Fluency Meet One Cognitive Mindset
ERIC Educational Resources Information Center
Reggev, Niv; Hassin, Ran R.; Maril, Anat
2012-01-01
Fluency, the subjective experience of ease associated with information processing, has been shown to affect a host of judgments. Previous research has typically focused on specific factors that affect the use of a single, specific fluency source. In the present study we examine how cognitive mindsets, or processing modes, moderate fluency…
Development of an Evidence-Based Reading Fluency Program for Adult Literacy Learners
ERIC Educational Resources Information Center
Shore, Jane; Sabatini, John; Lentini, Jennifer; Holtzman, Steven; McNeil, Adjua
2015-01-01
Fluency is an essential part of skilled reading that has only recently begun to receive its deserved attention. However, programs that meaningfully engage adult learners in fluency training have not been widely explored in research. In this article, the authors describe an evidence-based adult Guided Repeated Reading program developed for…
ERIC Educational Resources Information Center
Rinehart, Steven D.; Ahern, Terence C.
2016-01-01
Computer applications related to reading instruction have become commonplace in schools and link with established components of the reading process, emergent skills, decoding, comprehension, vocabulary, and fluency. This article focuses on computer technology in conjunction with durable methods for building oral reading fluency when readers…
Oral Reading Fluency Development for Children with Emotional Disturbance or Learning Disabilities
ERIC Educational Resources Information Center
Wanzek, Jeanne; Al Otaiba, Stephanie; Petscher, Yaacov
2014-01-01
This study used a large statewide database to examine the oral reading fluency development of second- and third-grade students with emotional disturbance or learning disabilities and their general education peers. Oral reading fluency measures were administered to 185,367 students without disabilities (general education), 2,146 students identified…
Evaluating Student Comprehension Performance Measured by Oral Reading Fluency and Retell Fluency
ERIC Educational Resources Information Center
McGann, Rachel M.
2017-01-01
This dissertation investigated student comprehension and its relationship to oral reading fluency. The DIBELS Next reading assessment was used to determine the relationship between these reading skills. This research also examined the relationship between the two comprehension measures of the DIBELS Next assessment that are identified by the…
Using an Intelligent Tutor and Math Fluency Training to Improve Math Performance
ERIC Educational Resources Information Center
Arroyo, Ivon; Royer, James M.; Woolf, Beverly P.
2011-01-01
This article integrates research in intelligent tutors with psychology studies of memory and math fluency (the speed to retrieve or calculate answers to basic math operations). It describes the impact of computer software designed to improve either strategic behavior or math fluency. Both competencies are key to improved performance and both…
The Effectiveness of Cooperative Learning Activities in Enhancing EFL Learners' Fluency
ERIC Educational Resources Information Center
Alrayah, Hassan
2018-01-01
This research-paper aims at examining the effectiveness of cooperative learning activities in enhancing EFL learners' fluency. The researcher has used the descriptive approach, recorded interviews for testing fluency as tools of data collection and the software program SPSS as a tool for the statistical treatment of data. Research sample consists…
ERIC Educational Resources Information Center
Idler, Alyssa M.; Mercer, Sterett H.; Starosta, Lindsay; Bartfai, Jamie M.
2017-01-01
Students with attentional difficulties are at greater risk for reading difficulties. To address this concern, we examined the extent to which adding a mindful breathing exercise to individual reading fluency interventions would improve gains in reading fluency, student-reported attention, and student-reported stress. In a restricted alternating…
The Relationship between Computational Fluency and Student Success in General Studies Mathematics
ERIC Educational Resources Information Center
Hegeman, Jennifer; Waters, Gavin
2012-01-01
Many developmental mathematics programs emphasize computational fluency with the assumption that this is a necessary contributor to student success in general studies mathematics. In an effort to determine which skills are most essential, scores on a computational fluency test were correlated with student success in general studies mathematics at…
Longitudinal Study on Fluency among Novice Learners of Japanese
ERIC Educational Resources Information Center
Hirotani, Maki; Matsumoto, Kazumi; Fukada, Atsusi
2012-01-01
The present study examined various aspects of the development of learners' fluency in Japanese using a large set of speech samples collected over a long period, using an online speaking practice/assessment system called "Speak Everywhere." The purpose of the present study was to examine: (1) how the fluency related measures changed over…
ERIC Educational Resources Information Center
Besken, Miri; Mulligan, Neil W.
2014-01-01
Judgments of learning (JOLs) are sometimes influenced by factors that do not impact actual memory performance. One recent proposal is that perceptual fluency during encoding affects metamemory and is a basis of metacognitive illusions. In the present experiments, participants identified aurally presented words that contained inter-spliced silences…
Teaching Reading Fluency to Struggling Readers: Method, Materials, and Evidence
ERIC Educational Resources Information Center
Rasinski, Timothy; Homan, Susan; Biggs, Marie
2009-01-01
Reading fluency has been identified as a key component in reading and in learning to read. Moreover, a significantly large number of students who experience difficulty in reading manifest difficulties in reading fluency that appear to contribute to their overall struggles in reading. In this article we explore the nature of effective instruction…
Australian Curriculum Linked Lessons. Fluency
ERIC Educational Resources Information Center
Hurrell, Derek
2014-01-01
In this article, Derek Hurrell, points out that while it's easy to fall into the impression that the proficiency strand "Fluency" is all about knowing basic number facts in all its many and splendid ways. He add it is easy to overlook, that within Fluency there are requirements that are based in Algebra; Measurement and Geometry; and…
How the Brain's Performance during Mathematics and Reading Fluency Tests Compare
ERIC Educational Resources Information Center
Ortiz, Enrique
2011-01-01
The purpose of this study was to analyze how participants' levels of hemoglobin as they performed mathematics fluency and reading fluency (reading comprehension) compare. We used Optical Topography (OT, helmet type brain-scanning system, also known as Functional Near-Infrared Spectroscopy or fNIRS) to measure levels of brain activity. A central…
Oral Reading Fluency Assessment: Issues of Construct, Criterion, and Consequential Validity
ERIC Educational Resources Information Center
Valencia, Sheila W.; Smith, Antony T.; Reece, Anne M.; Li, Min; Wixson, Karen K.; Newman, Heather
2010-01-01
This study investigated multiple models for assessing oral reading fluency, including 1-minute oral reading measures that produce scores reported as words correct per minute (wcpm). We compared a measure of wcpm with measures of the individual and combined indicators of oral reading fluency (rate, accuracy, prosody, and comprehension) to examine…
The Contributions of Oral and Silent Reading Fluency to Reading Comprehension
ERIC Educational Resources Information Center
Price, Katherine W.; Meisinger, Elizabeth B.; Louwerse, Max M.; D'Mello, Sidney
2016-01-01
Silent reading fluency has received limited attention in the school-based literatures across the past decade. We fill this gap by examining both oral and silent reading fluency and their relation to overall abilities in reading comprehension in fourth-grade students. Lower-level reading skills (word reading, rapid automatic naming) and vocabulary…
So Long, Robot Reader! A Superhero Intervention Plan for Improving Fluency
ERIC Educational Resources Information Center
Marcell, Barclay; Ferraro, Christine
2013-01-01
This article presents an engaging means for turning disfluent readers into prosody superstars. Each week students align with Poetry Power Man and his superhero friends to battle the evil Robot Reader and his sidekicks. The Fluency Foursome helps students adhere to the multidimensional aspects of fluency where expression and comprehension are…
Corporate Versus Academic Perceptions of the Need for Language Fluency.
ERIC Educational Resources Information Center
Vande Berg, Camille Kennedy
1997-01-01
Discusses the academic emphasis on students acquiring fluency in a second language to foster their advancement in the business world of international commerce. Notes that human resource experts in U.S.-based international corporations often give a low priority to linguistic fluency and emphasize the need for cultural expertise. (Seven references)…
Increasing Reading Fluency Performance of Students with Emotional and Behavioral Disorders
ERIC Educational Resources Information Center
Hanway Kalis, Tara M.
2012-01-01
Reading fluency has been identified as one of the essential skills students must develop in order to learn to read. Fluency is also a critical factor in reading comprehension (National Reading Panel [NRP], 2000). Many students, however, lack the ability to read age-appropriate materials fluently, including students with emotional and behavioral…
Nie, Jia; Zhang, Wei; Liu, Ying
2017-01-01
The aims of this study were to explore depression, self-esteem and verbal fluency functions among normal internet users, mild internet addictions and severe internet addictions. The survey sample consisted of 316 college students, and their internet addiction symptoms, depression and self-esteem symptoms were assessed using the Revised Chen Internet Addiction Scale (CIAS-R), Zung Self-Rating Depression Scale (ZSDS), Rosenberg Self-Esteem Scale (RSES), respectively. From this sample, 16 students with non-addictions, 19 students with mild internet addiction (sub-MIA) and 15 students with severe internet addiction (sub-SIA) were recruited and subjected to the classical verbal fluency tests, including the semantic and phonemic fluency task. The results indicated that severe internet addiction in the survey sample showed the highest tendency towards depressive symptoms and lowest self-esteem scores, and sub-SIA showed poor performance on the semantic fluency task. In conclusion, severe internet addiction was significantly associated with depression, low self-esteem and semantic verbal fluency problems. Copyright © 2017 Elsevier Inc. All rights reserved.
Denton, Carolyn A.; Barth, Amy E.; Fletcher, Jack M.; Wexler, Jade; Vaughn, Sharon; Cirino, Paul T.; Romain, Melissa; Francis, David J.
2011-01-01
The purpose of this study was to investigate the relations among oral and silent reading fluency and reading comprehension for students in Grades 6 to 8 (n = 1,421) and the use of fluency scores to identify middle school students who are at risk for failure on a high-stakes reading test. Results indicated moderate positive relations between measures of fluency and comprehension. Oral reading fluency (ORF) on passages was more strongly related to reading comprehension than ORF on word lists. A group-administered silent reading sentence verification test approximated the classification accuracy of individually administered ORF passages. The correlation between a maze task and comprehension was weaker than has been reported for elementary students. The best predictor of a high-stakes reading comprehension test was the previous year’s administration of the grade-appropriate test; fluency and verbal knowledge measures accounted for only small amounts of unique variance beyond that accounted for by the previous year’s administration. PMID:21637727
Swanson, H Lee; O'Connor, Rollanda
2009-01-01
The authors investigated whether practice in reading fluency had a causal influence on the relationship between working memory (WM) and text comprehension for 155 students in Grades 2 and 4 who were poor or average readers. Dysfluent readers were randomly assigned to repeated reading or continuous reading practice conditions and compared with untreated dysfluent and fluent readers on posttest measures of fluency, word identification, vocabulary, and reading comprehension. Three main findings emerged: (a) The influence of WM on text comprehension was not related to fluency training, (b) dysfluent readers in the continuous-reading condition had higher posttest scores than dysfluent readers in the other conditions on measures of text comprehension but not on vocabulary, and (c) individual differences in WM better predicted posttest comprehension performance than word-attack skills. In general, the results suggested that although continuous reading increased comprehension, fluency practice did not compensate for WM demands. The results were interpreted within a model that viewed reading comprehension processes as competing for a limited supply of WM resources that operate independent of fluency.
[Spanish verbal fluency. Normative data in Argentina].
Butman, J; Allegri, R F; Harris, P; Drake, M
2000-01-01
Letter and category fluency tasks are used to assess semantic knowledge, retrieval ability, and executive functioning. The original normative data have been obtained mainly from English speaking populations; there are few papers on norms in other languages. The purpose of this study was to collect normative scores in Argentina and to evaluate the effects of sex, age, education and cognitive status on the letter and category fluency tasks, in 266 healthy Spanish-speaking participants (16 to 86 years). Mean education span was 12.8 +/- 4 years. In each subject a neuropsychological battery (Minimental State Exam, Signoret Memory Battery, Boston Naming Test and Trail Making Test) was carried out as well as category fluency (naming animals in one minute) and letter fluency (words beginning with letter "p" in one minute). The sample was arranged into a group of subjects with less than 45 years and further groups up to 10 more years, until 75 years (or more) with three different levels of education. Significant effects were found for age, education, and Minimental State Exam on performance of both fluencies. Mean performance scores are presented for each group to be used in Argentina.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maynar, Manuel; Llorens, Rafael; Lopez-Sanchez, Carmen
Purpose. A method to create an extraluminal femoropopliteal bypass graft using endovascular techniques was evaluated in situ on cadaver extremities in an attempt to develop a minimally invasive alternative technique for the management of infrainguinal occlusive arterial disease. Methods. The endovascular placement of an extraluminal femoropopliteal bypass graft was undertaken in 5 cadaver legs. Following percutaneous access to the popliteal artery (PA) or common femoral artery (CFA), a Rosch-Uchida needle was used to perforate the vascular wall, followed by the creation of an extraluminal tract using a looped wire and catheter. Once the desired level was reached the needle wasmore » again used to perforate the vascular wall of the proximal superficial femoral artery (SFA) or PA depending on the access used. Self-expanding expanded polytetrafluoroethylene (ePTFE) stent-grafts were then deployed to establish the extraluminal femoropopliteal bypass connecting the two arterial puncture sites. Following dilatation of the stent-graft, angiography was performed to assess the endoprostheses and to look for contrast leaks. Results. Technical success was achieved in all 5 legs. Procedure time varied from 15 to 30 min. The angiographic studies performed immediately after completion of the bypass procedure showed patency of the grafts with no evidence of kinking or leakage in any of the cases. Conclusion. This study has proved that the endovascular placement of an extraluminal femoropopliteal bypass graft in human cadaver legs using endovascular techniques under fluoroscopic control is technically feasible.« less
NASA Astrophysics Data System (ADS)
Miyamoto, Ryoma; Utano, Tatsumi; Yasuhara, Shunya; Ishihara, Shota; Ohshima, Masahiro
2015-05-01
In this study, the core-back foam injection molding was used for preparing microcelluar polypropylene (PP) foam with either a 1,3:2,4 bis-O-(4-methylbenzylidene)-D-sorbitol gelling agent (Gel-all MD) or a fibros network polymer additive (Metablen 3000). Both agent and addiive could effectively control the celluar morphology in foams but somehow different ways. In course of cooling the polymer with Gel-all MD in the mold caity, the agent enhanced the crystal nucleation and resulted in the large number of small crystals. The crystals acted as effective bubble nucleation agent in foaming process. Thus, the agent reduced the cell size and increased the cell density, drastically. Furthermore, the small crystals provided an inhomogenuity to the expanding cell wall and produced the high open cell content with nano-scale fibril structure. Gell-all as well as Metablene 3000 formed a gel-like fibrous network in melt. The network increased the elongational viscosity and tended to prevent the cell wall from breaking up. The foaming temperature window was widened by the presence of the network. Especially, the temperature window where the macro-fibrous structure was formed was expanded to the higher temperature. The effects of crystal nucleating agent and PTFE on crystals' size and number, viscoelsticity, rheological propreties of PP and cellular morphology were compared and thorougly investigated.
Workplace in fluency management: factoring the workplace into fluency management.
Cassar, M C; Neilson, M D
1997-01-01
This article addresses competency-based standards and guidelines for the involvement of speech-language pathologists in the workplace of clients who stutter. It advocates broadening customary practices in stuttering treatment and suggests that speech-language pathologists should extend their scope of service delivery to the workplace. It presents a sequence for the collaborative involvement of the employer and other workplace members and proposes strategies for evaluating workplace based fluency programs. Issues of fluency management, transfer, maintenance, and efficacy are discussed in the workplace context. Also addressed is workplace communication as well as such factors as stereotypes, discrimination, and resistance to change which may impinge on workplace intervention. It is argued that structured intervention, transfer, and generalization within a collaborative workplace framework facilitates best practice for the fluency clinician and more appropriate outcomes for the diversity of clients who stutter.
Holtzer, R.; Goldin, Y.; Donovick, P.J.
2010-01-01
We examined whether extending the administration time of letter fluency from one minute per letter trial (standard administration) to two minutes increased the sensitivity of this test to cognitive status in aging. Participants (mean age = 84.6) were assigned to cognitive impairment (n=20) and control (n=40) groups. Pearson correlations and scatter plot analyses showed that associations between the Dementia Rating Scale scores and letter fluency were higher and less variable when performance on the latter was extended to two minutes. ANOVA showed that the cognitive impairment group generated fewer words in the second minute of the letter fluency task compared to the control group. Finally, discriminant function analyses revealed that extending the letter fluency trials to two minutes increased discrimination between the control and cognitive impairment groups. PMID:19449244