Sample records for fluid diagnostic evaluation

  1. Diagnosing periprosthetic joint infection: has the era of the biomarker arrived?

    PubMed

    Deirmengian, Carl; Kardos, Keith; Kilmartin, Patrick; Cameron, Alexander; Schiller, Kevin; Parvizi, Javad

    2014-11-01

    The diagnosis of periprosthetic joint infection (PJI) remains a serious clinical challenge. There is a pressing need for improved diagnostic testing methods; biomarkers offer one potentially promising approach. We evaluated the diagnostic characteristics of 16 promising synovial fluid biomarkers for the diagnosis of PJI. Synovial fluid was collected from 95 patients meeting the inclusion criteria of this prospective diagnostic study. All patients were being evaluated for a revision hip or knee arthroplasty, including patients with systemic inflammatory disease and those already receiving antibiotic treatment. The Musculoskeletal Infection Society (MSIS) definition was used to classify 29 PJIs and 66 aseptic joints. Synovial fluid samples were tested by immunoassay for 16 biomarkers optimized for use in synovial fluid. Sensitivity, specificity, and receiver operating characteristic curve analysis were performed to assess for diagnostic performance. Five biomarkers, including human α-defensin 1-3, neutrophil elastase 2, bactericidal/permeability-increasing protein, neutrophil gelatinase-associated lipocalin, and lactoferrin, correctly predicted the MSIS classification of all patients in this study, with 100% sensitivity and specificity for the diagnosis of PJI. An additional eight biomarkers demonstrated excellent diagnostic strength, with an area under the curve of greater than 0.9. Synovial fluid biomarkers exhibit a high accuracy in diagnosing PJI, even when including patients with systemic inflammatory disease and those receiving antibiotic treatment. Considering that these biomarkers match the results of the more complex MSIS definition of PJI, we believe that synovial fluid biomarkers can be a valuable addition to the methods utilized for the diagnosis of infection. Level II, diagnostic study. See Instructions for Authors for a complete description of levels of evidence.

  2. Evaluating the diagnostic accuracy of the Xpert MTB/RIF assay on bronchoalveolar lavage fluid: A retrospective study.

    PubMed

    Lu, Yanjun; Zhu, Yaowu; Shen, Na; Tian, Lei; Sun, Ziyong

    2018-02-08

    Limited data on the diagnostic accuracy of the Xpert MTB/RIF assay using bronchoalveolar lavage fluid from patients with suspected pulmonary tuberculosis (PTB) have been reported in China. Therefore, a retrospective study was designed to evaluate the diagnostic accuracy of this assay. Clinical, radiological, and microbiological characteristics of 238 patients with suspected PTB were reviewed retrospectively. The sensitivity, specificity, positive predictive value, and negative predictive value for the diagnosis of active PTB were calculated for the Xpert MTB/RIF assay using TB culture or final diagnosis based on clinical and radiological evaluation as the reference standard. The sensitivity and specificity of the Xpert MTB/RIF assay were 84.5% and 98.9%, respectively, and those for smear microscopy were 36.2% and 100%, respectively, when compared to the culture method. However, compared with the sensitivity and specificity of final diagnosis based on clinical and radiological evaluation, the sensitivity and specificity of the assay were 72.9% and 98.7%, respectively, which were significantly higher than those for smear microscopy. The Xpert MTB/RIF assay on bronchoalveolar lavage fluid could serve as an additional rapid diagnostic tool for PTB in a high TB-burden country and improve the time to TB treatment initiation in patients with PTB. Copyright © 2018 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  3. Cyst fluid telomerase activity predicts the histologic grade of cystic neoplasms of the pancreas

    PubMed Central

    Hata, Tatsuo; Molin, Marco Dal; Suenaga, Masaya; Yu, Jun; Pittman, Meredith; Weiss, Matthew; Canto, Marcia I.; Wolfgang, Christopher; Lennon, Anne Marie; Hruban, Ralph H; Goggins, Michael

    2016-01-01

    Purpose Pancreatic cysts frequently pose clinical dilemmas. On one hand, cysts with high-grade dysplasia offer opportunities for cure, on the other hand, those with low-grade dysplasia are easily over treated. Cyst fluid markers have the potential to improve the evaluation of these cysts. Since telomerase activity is commonly activated in malignant cells, we evaluated the diagnostic performance of cyst fluid telomerase activity measurements for predicting histologic grade. Experimental design Telomerase activity was measured using telomerase repeat amplification with digital-droplet PCR in surgically-aspirated cyst fluid samples from 219 patients who underwent pancreatic resection for a cystic lesion (184, discovery, 35 validation) and 36 patients who underwent endoscopic ultrasound fine needle aspiration. Methodological and clinical factors associated with telomerase activity were examined. Results Telomerase activity was reduced in samples that had undergone prior thawing. Among 119 samples not previously thawed, surgical cyst fluids from cystic neoplasms with high-grade dysplasia +/− associated invasive cancer had higher telomerase activity (median [interquartile range], 1158 [295.9–13033] copies/μL of cyst fluid than those without (19.74 [2.58–233.6] copies/μL) (P < 0.001). Elevated cyst fluid telomerase activity had a diagnostic accuracy for invasive cancer/high-grade dysplasia of 88.1% (discovery), 88.6% (validation), and 88.2% (merged). Among cysts classified preoperatively as having “worrisome features”, cyst fluid telomerase activity had high diagnostic performance (sensitivity 73.7%, specificity 90.6%, accuracy, 86.1%). In multivariate analysis, telomerase activity independently predicted the presence of invasive cancer/high-grade dysplasia. Conclusion Cyst fluid telomerase activity can be a useful predictor of the neoplastic grade of pancreatic cysts. PMID:27230749

  4. An update on the use of cerebrospinal fluid analysis as a diagnostic tool in multiple sclerosis.

    PubMed

    Gastaldi, Matteo; Zardini, Elisabetta; Franciotta, Diego

    2017-01-01

    Intrathecal B-lymphocyte activation is a hallmark of multiple sclerosis (MS), a multi-factorial inflammatory-demyelinating disease of the central nervous system. Such activation has a counterpart in the cerebrospinal fluid (CSF) oligoclonal IgG bands (OCB), whose diagnostic role in MS has been downgraded within the current McDonald's criteria. With a theoretico-practical approach, the authors review the physiopathological basis of the CSF dynamics, and the state-of-the-art of routine CSF analysis and CSF biomarkers in MS. Areas covered: The authors discuss pros and cons of CSF analysis, including critical evaluations of both well-established, and promising diagnostic and prognostic laboratory tools. New acquisitions on the CSF and cerebral interstitial fluid dynamics are also presented. The authors searched the PubMed database for English-language articles reported between January 2010 and June 2016, using the key words 'multiple sclerosis', 'cerebrospinal fluid', 'oligoclonal bands'. Reference lists of relevant articles were scanned for additional studies. Expert commentary: The availability of performing high-quality, routine CSF tests in specialized laboratories, the emerging potential of novel CSF biomarkers, and the trend for early treatments should induce a reappraisal of CSF analysis for diagnostic and prognostic purposes in MS. Further procedural and methodological improvements seem to be necessary in both research and translational diagnostic CSF settings.

  5. Current approach in the diagnosis and management of posterior uveitis

    PubMed Central

    Sudharshan, S; Ganesh, Sudha K; Biswas, Jyotrimay

    2010-01-01

    Posterior uveitic entities are varied entities that are infective or non-infective in etiology. They can affect the adjacent structures such as the retina, vitreous, optic nerve head and retinal blood vessels. Thorough clinical evaluation gives a clue to the diagnosis while ancillary investigations and laboratory tests assist in confirming the diagnosis. Newer evolving techniques in the investigations and management have increased the diagnostic yield. In case of diagnostic dilemma, intraocular fluid evaluation for polymerase chain testing for the genome and antibody testing against the causative agent provide greater diagnostic ability. PMID:20029144

  6. Influence of thyroid gland status on the thyroglobulin cutoff level in washout fluid from cervical lymph nodes of patients with recurrent/metastatic papillary thyroid cancer.

    PubMed

    Lee, Jun Ho; Lee, Hyun Chul; Yi, Ha Woo; Kim, Bong Kyun; Bae, Soo Youn; Lee, Se Kyung; Choe, Jun-Ho; Kim, Jung-Han; Kim, Jee Soo

    2016-04-01

    The influence of serum thyroglobulin (Tg) and thyroidectomy status on Tg in fine-needle aspiration cytology (FNAC) washout fluid is unclear. A total of 282 lymph nodes were prospectively subjected to FNAC, fine-needle aspiration (FNA)-Tg measurement, and frozen and permanent biopsies. We evaluated the diagnostic performance of several predetermined FNA-Tg cutoff values for recurrence/metastasis in lymph nodes according to thyroidectomy status. The diagnostic performance of FNA-Tg varied according to thyroidectomy status. The optimized cutoff value of FNA-Tg was 2.2 ng/mL. However, among FNAC-negative lymph nodes, the FNA-Tg cutoff value of 0.9 ng/mL showed better diagnostic performance in patients with a thyroid gland. An FNA-Tg/serum-Tg cutoff ratio of 1 showed the best diagnostic performance in patients without a thyroid gland. Applying the optimal cutoff values of FNA-Tg according to thyroid gland status and serum Tg level facilitates the diagnostic evaluation of neck lymph node recurrences/metastases in patients with papillary thyroid carcinoma (PTC). © 2015 Wiley Periodicals, Inc. Head Neck 38: E1705-E1712, 2016. © 2015 Wiley Periodicals, Inc.

  7. Diagnostic Lumbar Puncture

    PubMed Central

    Doherty, Carolynne M; Forbes, Raeburn B

    2014-01-01

    Diagnostic Lumbar Puncture is one of the most commonly performed invasive tests in clinical medicine. Evaluation of an acute headache and investigation of inflammatory or infectious disease of the nervous system are the most common indications. Serious complications are rare, and correct technique will minimise diagnostic error and maximise patient comfort. We review the technique of diagnostic Lumbar Puncture including anatomy, needle selection, needle insertion, measurement of opening pressure, Cerebrospinal Fluid (CSF) specimen handling and after care. We also make some quality improvement suggestions for those designing services incorporating diagnostic Lumbar Puncture. PMID:25075138

  8. Comparison of diagnostic performances among bronchoscopic sampling techniques in the diagnosis of peripheral pulmonary lesions.

    PubMed

    Boonsarngsuk, Viboon; Kanoksil, Wasana; Laungdamerongchai, Sarangrat

    2015-04-01

    There are many sampling techniques dedicated to radial endobronchial ultrasound (R-EBUS) guided flexible bronchoscopy (FB). However, data regarding the diagnostic performances among bronchoscopic sampling techniques is limited. This study was conducted to compare the diagnostic yields among bronchoscopic sampling techniques in the diagnosis of peripheral pulmonary lesions (PPLs). A prospective study was conducted on 112 patients who were diagnosed with PPLs and underwent R-EBUS-guided FB between Oct 2012 and Sep 2014. Sampling techniques-including transbronchial biopsy (TBB), brushing cell block, brushing smear, rinsed fluid of brushing, and bronchoalveolar lavage (BAL)-were evaluated for the diagnosis. The mean diameter of the PPLs was 23.5±9.5 mm. The final diagnoses included 76 malignancies and 36 benign lesions. The overall diagnostic yield of R-EBUS-guided bronchoscopy was 80.4%; TBB gave the highest yield among the 112 specimens: 70.5%, 34.8%, 62.5%, 50.0% and 42.0% for TBB, brushing cell block, brushing smear, rinsed brushing fluid, and BAL fluid (BALF), respectively (P<0.001). TBB provided high diagnostic yield irrespective of the size and etiology of the PPLs. The combination of TBB and brushing smear achieved the maximum diagnostic yield. Of 31 infectious PPLs, BALF culture gave additional microbiological information in 20 cases. TBB provided the highest diagnostic yield; however, to achieve the highest diagnostic performance, TBB, brushing smear and BAL techniques should be performed together.

  9. Comparison of ultrasonography, radiography and a single computed tomography slice for the identification of fluid within the tympanic bulla of rabbit cadavers.

    PubMed

    King, A M; Posthumus, J; Hammond, G; Sullivan, M

    2012-08-01

    Evaluation of the tympanic bulla (TB) in cases of otitis media in the rabbit can be a diagnostic challenge, although a feature often associated with the condition is the accumulation of fluid or material within the TB. Randomly selected TB from 40 rabbit cadavers were filled with a water-based, water-soluble jelly lubricant. A dorsoventral radiograph and single computed tomography (CT) slice were taken followed by an ultrasound (US) examination. Image interpretation was performed by blinded operators. The content of each TB was determined (fluid or gas) using each technique and the cadavers were frozen and sectioned for confirmation. CT was the most accurate diagnostic method, but US produced better results than radiography. Given the advantages of US over the other imaging techniques, the results suggest that further work is warranted to determine US applications in the evaluation of the rabbit TB and clinical cases of otitis media in this species. Copyright © 2012 Elsevier Ltd. All rights reserved.

  10. Comparative evaluation of serum, FTA filter-dried blood and oral fluid as sample material for PRRSV diagnostics by RT-qPCR in a small-scale experimental study.

    PubMed

    Steinrigl, Adolf; Revilla-Fernández, Sandra; Wodak, Eveline; Schmoll, Friedrich; Sattler, Tatjana

    2014-01-01

    Recently, research into alternative sample materials, such as oral fluid or filter-dried blood has been intensified, in order to facilitate cost-effective and animal-friendly sampling of individuals or groups of pigs for diagnostic purposes. The objective of this study was to compare the sensitivity of porcine reproductive and respiratory syndrome virus (PRRSV)-RNA detection by reverse transcription quantitative real-time PCR (RT-qPCR) in serum, FTA filter-dried blood and oral fluid sampled from individual pigs. Ten PRRSV negative pigs were injected with an EU-type PRRSV live vaccine. Blood and oral fluid samples were taken from each pig before, and 4, 7, 14 and 21 days after vaccination. All samples were then analyzed by PRRSV RT-qPCR. In serum, eight often pigs tested RT-qPCR positive at different time points post infection. Absolute quantification showed low serum PRRSV-RNA loads in most samples. In comparison to serum, sensitivity of PRRSV-RNA detection was strongly reduced in matched FTA filter-dried blood and in oral fluid from the same pigs. These results indicate that with low PRRSV-RNA loads the diagnostic sensitivity of PRRSV-RNA detection by RT-qPCR achieved with serum is currently unmatched by either FTA filter-dried blood or oral fluid.

  11. Clinical Comparison of Conventional and Mobile Endockscope Videocystoscopy Using an Air or Fluid Medium.

    PubMed

    Dutta, Rahul; Yoon, Renai; Patel, Roshan M; Spradling, Kyle; Okhunov, Zhamshid; Sohn, William; Lee, Hak J; Landman, Jaime; Clayman, Ralph V

    2017-06-01

    To compare conventional videocystoscopy (CVC) with a novel and affordable (approximately $45) mobile cystoscopy system, the Endockscope (ES). We evaluated the ES system using both fluid (Endockscope-Fluid [ES-F]) and air (Endockscope-Air [ES-A]) to fill the bladder in an effort to expand the global range of flexible cystoscopy. The ES system comprised a portable 1000 lumen LED self-contained cordless light source and a three-dimensional printed adaptor that connects a mobile phone to a flexible fiber-optic cystoscope. Patients undergoing in-office cystoscopic evaluation for either stent removal or bladder cancer surveillance received three examinations: conventional, ES-F, and ES-A cystoscopy. Videos of each examination were recorded and analyzed by expert endoscopists for image quality/resolution, brightness, color quality, sharpness, overall quality, and whether or not they were acceptable for diagnostic purposes. Six of the 10 patients for whom the conventional videos were 100% acceptable for diagnostic purposes were included in our analysis. The conventional videos scored higher on every metric relative to both the ES-F and ES-A videos (p < 0.05). There was no difference between ES-F and ES-A videos on any metric. Fifty-two percent and 44% of the ES-F and ES-A videos, respectively, were considered acceptable for diagnostic purposes (p = 0.384). The ES mobile cystoscopy system may be a reasonable option in settings where electricity, sterile fluid irrigant, or access to CVC equipment is unavailable.

  12. Myofibroblasts in interstitial lung diseases show diverse electron microscopic and invasive features.

    PubMed

    Karvonen, Henna M; Lehtonen, Siri T; Sormunen, Raija T; Harju, Terttu H; Lappi-Blanco, Elisa; Bloigu, Risto S; Kaarteenaho, Riitta L

    2012-09-01

    The characteristic features of myofibroblasts in various lung disorders are poorly understood. We have evaluated the ultrastructure and invasive capacities of myofibroblasts cultured from small volumes of diagnostic bronchoalveolar lavage (BAL) fluid samples from patients with different types of lung diseases. Cells were cultured from samples of BAL fluid collected from 51 patients that had undergone bronchoscopy and BAL for diagnostic purposes. The cells were visualized by transmission electron microscopy and immunoelectron microscopy to achieve ultrastructural localization of alpha-smooth muscle actin (α-SMA) and fibronectin. The levels of α-SMA protein and mRNA and fibronectin mRNA were measured by western blot and quantitative real-time reverse transcriptase polymerase chain reaction. The invasive capacities of the cells were evaluated. The cultured cells were either fibroblasts or myofibroblasts. The structure of the fibronexus, and the amounts of intracellular actin, extracellular fibronectin and cell junctions of myofibroblasts varied in different diseases. In electron and immunoelectron microscopy, cells cultured from interstitial lung diseases (ILDs) expressed more actin filaments and α-SMA than normal lung. The invasive capacity of the cells obtained from patients with idiopathic pulmonary fibrosis was higher than that from patients with other type of ILDs. Cells expressing more actin filaments had a higher invasion capacity. It is concluded that electron and immunoelectron microscopic studies of myofibroblasts can reveal differential features in various diseases. An analysis of myofibroblasts cultured from diagnostic BAL fluid samples may represent a new kind of tool for diagnostics and research into lung diseases.

  13. Pleural fluid neopterin levels in tuberculous pleurisy.

    PubMed

    Cok, Gursel; Parildar, Zuhal; Basol, Gunes; Kabaroglu, Ceyda; Bayindir, Ulku; Habif, Sara; Bayindir, Oya

    2007-08-01

    Neopterin is produced by stimulated macrophages under the influence of gamma interferon of lymphocyte origin. It is regarded as a biochemical marker of cell-mediated immune response. This study was designed to assess the diagnostic value of pleural fluid neopterin levels in tuberculous pleurisy in comparison with adenosine deaminase activity. Pleural fluid adenosine deaminase (ADA) activity and neopterin levels were measured in 16 patients with tuberculous pleurisy (TP) and 19 patients with malignant pleurisy (MP). ADA activity was determined by a colorimetric method, whereas neopterin levels were determined by a reversed-phase liquid chromatography technique. All values were given as median (min-max). The mean age was 45.43+/-20.39 years in the TP group and 60.42+/-11.02 years in the MP group (p=0.026). The median pleural fluid ADA activity was 51.75 U/L (3.50-62.40 U/L) in the TP group and was 2.30 U/L (1-8.20 U/L) in the MP group. The difference was statistically significant (p<0.001). The median pleural fluid neopterin levels were 13.15 nmol/L (1.86-59.50 nmol/L) and 2.44 nmol/L (0.92-27.60 nmol/L) in the TP group and the MP group, respectively (p=0.021). In order to evaluate the diagnostic value of pleural fluid neopterin concentrations, receiver-operating-characteristic curve analysis was performed. Pleural fluid neopterin concentration is significantly higher in TP when compared to MP, however when compared, its clinical use as a diagnostic marker is not valuable as ADA.

  14. Searching for neurodegeneration in multiple sclerosis at clinical onset: Diagnostic value of biomarkers.

    PubMed

    Novakova, Lenka; Axelsson, Markus; Malmeström, Clas; Imberg, Henrik; Elias, Olle; Zetterberg, Henrik; Nerman, Olle; Lycke, Jan

    2018-01-01

    Neurodegeneration occurs during the early stages of multiple sclerosis. It is an essential, devastating part of the pathophysiology. Tools for measuring the degree of neurodegeneration could improve diagnostics and patient characterization. This study aimed to determine the diagnostic value of biomarkers of degeneration in patients with recent clinical onset of suspected multiple sclerosis, and to evaluate these biomarkers for characterizing disease course. This cross-sectional study included 271 patients with clinical features of suspected multiple sclerosis onset and was the baseline of a prospective study. After diagnostic investigations, the patients were classified into the following disease groups: patients with clinically isolated syndrome (n = 4) or early relapsing remitting multiple sclerosis (early RRMS; n = 93); patients with relapsing remitting multiple sclerosis with disease durations ≥2 years (established RRMS; n = 39); patients without multiple sclerosis, but showing symptoms (symptomatic controls; n = 89); and patients diagnosed with other diseases (n = 46). In addition, we included healthy controls (n = 51) and patients with progressive multiple sclerosis (n = 23). We analyzed six biomarkers of neurodegeneration: cerebrospinal fluid neurofilament light chain levels; cerebral spinal fluid glial fibrillary acidic protein; cerebral spinal fluid tau; retinal nerve fiber layer thickness; macula volume; and the brain parenchymal fraction. Except for increased cerebral spinal fluid neurofilament light chain levels, median 670 ng/L (IQR 400-2110), we could not find signs of early degeneration in the early disease group with recent clinical onset. However, the intrathecal immunoglobin G production and cerebral spinal fluid neurofilament light chain levels showed diagnostic value. Moreover, elevated levels of cerebral spinal fluid glial fibrillary acidic protein, thin retinal nerve fiber layers, and low brain parenchymal fractions were associated with progressive disease, but not with the other phenotypes. Thin retinal nerve fiber layers and low brain parenchymal fractions, which indicated neurodegeneration, were associated with longer disease duration. In clinically suspected multiple sclerosis, intrathecal immunoglobin G production and neurofilament light chain levels had diagnostic value. Therefore, these biomarkers could be included in diagnostic work-ups for multiple sclerosis. We found that the thickness of the retinal nerve fiber layer and the brain parenchymal fraction were not different between individuals that were healthy, symptomatic, or newly diagnosed with multiple sclerosis. This finding suggested that neurodegeneration had not reached a significant magnitude in patients with a recent clinical onset of multiple sclerosis.

  15. Diagnostic accuracy of peripheral venous lactate and the 2009 WHO warning signs for identifying severe dengue in Thai adults: a prospective observational study.

    PubMed

    Thanachartwet, Vipa; Wattanathum, Anan; Oer-areemitr, Nittha; Jittmittraphap, Akanitt; Sahassananda, Duangjai; Monpassorn, Chalida; Surabotsophon, Manoon; Desakorn, Varunee

    2016-02-01

    Dengue is the most common mosquito-borne viral disease in humans. However, the sensitivities of warning signs (WSs) for identifying severe dengue in adults are low, and the utility of lactate levels for identifying severe dengue in adults has not been verified. Therefore, we aimed to evaluate the diagnostic accuracy of using peripheral venous lactate levels (PVL), as well as WSs established by the World Health Organization, for identifying severe dengue. We prospectively evaluated individuals hospitalized for dengue who were admitted to the Hospital for Tropical Diseases in Thailand between May 2013 and January 2015. Blood samples to evaluate PVL levels were collected at admission and every 24 h until the patient exhibited a body temperature of <37.8 °C for at least 24 h. Data were recorded on a pre-defined case report form, including baseline characteristics, clinical parameters, and laboratory findings. Among 125 patients with confirmed dengue, 105 (84.0%) patients had non-severe dengue, and 20 (16.0%) patients had severe dengue. The presence of clinical fluid accumulation as a WS provided high sensitivity (75.0%, 95% confidence interval [CI]: 50.9-91.3%) and specificity (90.5%, 95% CI: 83.2-95.3%). The PVL level at admission was used to evaluate its diagnostic value, and receiver operating characteristic curve analysis revealed an area under the curve of 0.84 for identifying severe dengue. At the optimal cutoff value (PVL: 2.5 mmol/L), the sensitivity and specificity were 65.0% (95% CI: 40.8-84.6%) and 96.2% (95% CI: 90.5-99.0%), respectively. A combined biomarker comprising clinical fluid accumulation and/or PVL of ≥2.5 mmol/L provided the maximum diagnostic accuracy for identifying severe dengue, with a sensitivity of 90.0% (95% CI: 68.3-98.8%) and a specificity of 87.6% (95% CI: 79.8-93.2%). Clinical fluid accumulation and/or PVL may be used as a diagnostic biomarker of severe dengue among adults. This biomarker may facilitate early recognition and timely treatment of patients with severe dengue, which may reduce dengue-related mortality and hospital burden.

  16. Diagnostic Value of Cerebrospinal Fluid T-SPOT.TB for Tuberculousis Meningitis in China.

    PubMed

    Li, Xue Lian; Xie, Na; Wang, Song Wang; Wu, Qian Hong; Ma, Yan; Shu, Wei; Chen, Hong Mei; Zhang, Li Qun; Wu, Xiao Guang; Ma, Li Ping; Che, Nan Ying; Gao, Meng Qiu

    2017-09-01

    The aim of this study was to evaluate the diagnostic value of the cerebrospinal fluid (CSF) T-SPOT.TB test for the diagnosis of TB meningitis (TBM). A retrospective analysis of 96 patients with manifested meningitis was conducted; T-SPOT.TB test was performed for diagnosing TBM to determine the diagnostic sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). A receiver operating characteristic (ROC) curve was also drawn to assess the diagnostic accuracy. The sensitivity, specificity, PPV, and NPV of CSF T-SPOT.TB test were 97.8%, 78.0%, 80.3%, and 97.5%, respectively, for 52 patients (54.2%) of the 96 enrolled patients. The area under the curve (AUC) was 0.910, and the sensitivities of CSF T-SPOT.TB for patients with stages I, II, and III of TBM were 96.7%, 97.2%, and 98.9%, respectively. CSF T-SPOT.TB test is a rapid and accurate diagnostic method with higher sensitivity and specificity for diagnosing TBM. Copyright © 2017 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.

  17. Optimization and Evaluation of a PCR Assay for Detecting Toxoplasmic Encephalitis in Patients with AIDS

    PubMed Central

    Joseph, Priya; Calderón, Maritza M.; Gilman, Robert H.; Quispe, Monica L.; Cok, Jaime; Ticona, Eduardo; Chavez, Victor; Jimenez, Juan A.; Chang, Maria C.; Lopez, Martín J.; Evans, Carlton A.

    2002-01-01

    Toxoplasma gondii is a common life-threatening opportunistic infection. We used experimental murine T. gondii infection to optimize the PCR for diagnostic use, define its sensitivity, and characterize the time course and tissue distribution of experimental toxoplasmosis. PCR conditions were adjusted until the assay reliably detected quantities of DNA derived from less than a single parasite. Forty-two mice were inoculated intraperitoneally with T. gondii tachyzoites and sacrificed from 6 to 72 h later. Examination of tissues with PCR and histology revealed progression of infection from blood to lung, heart, liver, and brain, with PCR consistently detecting parasites earlier than microscopy and with no false-positive results. We then evaluated the diagnostic value of this PCR assay in human patients. We studied cerebrospinal fluid and serum samples from 12 patients with AIDS and confirmed toxoplasmic encephalitis (defined as positive mouse inoculation and/or all of the Centers for Disease Control clinical diagnostic criteria), 12 human immunodeficiency virus-infected patients with suspected cerebral toxoplasmosis who had neither CDC diagnostic criteria nor positive mouse inoculation, 26 human immunodeficiency virus-infected patients with other opportunistic infections and no signs of cerebral toxoplasmosis, and 18 immunocompetent patients with neurocysticercosis. Eleven of the 12 patients with confirmed toxoplasmosis had positive PCR results in either blood or cerebrospinal fluid samples (6 of 9 blood samples and 8 of 12 cerebrospinal fluid samples). All samples from control patients were negative. This study demonstrates the high sensitivity, specificity, and clinical utility of PCR in the diagnosis of toxoplasmic encephalitis in a resource-poor setting. PMID:12454142

  18. Microfluidic Purification and Concentration of Malignant Pleural Effusions for Improved Molecular and Cytomorphological Diagnostics

    PubMed Central

    Go, Derek E.; Talati, Ish; Ying, Yong; Rao, Jianyu; Kulkarni, Rajan P.; Di Carlo, Dino

    2013-01-01

    Evaluation of pleural fluids for metastatic cells is a key component of diagnostic cytopathology. However, a large background of smaller leukocytes and/or erythrocytes can make accurate diagnosis difficult and reduce specificity in identification of mutations of interest for targeted anti-cancer therapies. Here, we describe an automated microfluidic system (Centrifuge Chip) which employs microscale vortices for the size-based isolation and concentration of cancer cells and mesothelial cells from a background of blood cells. We are able to process non-diluted pleural fluids at 6 mL/min and enrich target cells significantly over the background; we achieved improved purity in all patient samples analyzed. The resulting isolated and viable cells are readily available for immunostaining, cytological analysis, and detection of gene mutations. To demonstrate the utility towards aiding companion diagnostics, we also show improved detection accuracy of KRAS gene mutations in lung cancer cells processed using the Centrifuge Chip, leading to an increase in the area under the curve (AUC) of the receiver operating characteristic from 0.90 to 0.99. The Centrifuge Chip allows for rapid concentration and processing of large volumes of bodily fluid samples for improved cytological diagnosis and purification of cells of interest for genetic testing, which will be helpful for enhancing diagnostic accuracy. PMID:24205153

  19. Diagnostic Tools for Performance Evaluation of Innovative In-Situ Remediation Technologies at Chlorinated Solvent-Contaminated Sites

    DTIC Science & Technology

    2011-07-01

    fluid resistivity , temperature logging, and flow metering at other sites that typically indicated only two or three active fractures in each hole...was consistent with results of conventional borehole fluid resistivity , temperature logging, and flow metering at other sites that typically indicated...following tests were performed in each boundary monitoring well: ■ Gamma Ray; ■ Spontaneous Potential (SP); ■ Single Point Resistance (SPR

  20. Evaluation of the use of automatic exposure control and automatic tube potential selection in low-dose cerebrospinal fluid shunt head CT.

    PubMed

    Wallace, Adam N; Vyhmeister, Ross; Bagade, Swapnil; Chatterjee, Arindam; Hicks, Brandon; Ramirez-Giraldo, Juan Carlos; McKinstry, Robert C

    2015-06-01

    Cerebrospinal fluid shunts are primarily used for the treatment of hydrocephalus. Shunt complications may necessitate multiple non-contrast head CT scans resulting in potentially high levels of radiation dose starting at an early age. A new head CT protocol using automatic exposure control and automated tube potential selection has been implemented at our institution to reduce radiation exposure. The purpose of this study was to evaluate the reduction in radiation dose achieved by this protocol compared with a protocol with fixed parameters. A retrospective sample of 60 non-contrast head CT scans assessing for cerebrospinal fluid shunt malfunction was identified, 30 of which were performed with each protocol. The radiation doses of the two protocols were compared using the volume CT dose index and dose length product. The diagnostic acceptability and quality of each scan were evaluated by three independent readers. The new protocol lowered the average volume CT dose index from 15.2 to 9.2 mGy representing a 39 % reduction (P < 0.01; 95 % CI 35-44 %) and lowered the dose length product from 259.5 to 151.2 mGy/cm representing a 42 % reduction (P < 0.01; 95 % CI 34-50 %). The new protocol produced diagnostically acceptable scans with comparable image quality to the fixed parameter protocol. A pediatric shunt non-contrast head CT protocol using automatic exposure control and automated tube potential selection reduced patient radiation dose compared with a fixed parameter protocol while producing diagnostic images of comparable quality.

  1. Clinical outcomes of pediatric patients with acute abdominal pain and incidental findings of free intraperitoneal fluid on diagnostic imaging.

    PubMed

    Matz, Samantha; Connell, Mary; Sinha, Madhumita; Goettl, Christopher S; Patel, Palak C; Drachman, David

    2013-09-01

    The presence of free intraperitoneal fluid on diagnostic imaging (sonography or computed tomography [CT]) may indicate an acute inflammatory process in children with abdominal pain in a nontraumatic setting. Although clinical outcomes of pediatric trauma patients with free fluid on diagnostic examinations without evidence of solid-organ injury have been studied, similar studies in the absence of trauma are rare. Our objective was to study clinical outcomes of children with acute abdominal pain of nontraumatic etiology and free intraperitoneal fluid on diagnostic imaging (abdominal/pelvic sonography, CT, or both). We conducted a retrospective review of medical records of children aged 0 to 18 years presenting to a pediatric emergency department with acute abdominal pain (nontraumatic) between April 2008 and March 2009. Patients with intraperitoneal free fluid on imaging were divided into 2 groups: group I, imaging suggestive of an intra-abdominal surgical condition such as appendicitis; and group II, no evidence of an acute surgical condition on imaging, including patients with equivocal studies. Computed tomograms and sonograms were reviewed by a board-certified radiologist, and the free fluid volume was quantitated. Of 1613 patients who underwent diagnostic imaging, 407 were eligible for the study; 134 (33%) had free fluid detected on diagnostic imaging. In patients with both sonography and CT, there was a significant correlation in the free fluid volume (r = 0.79; P < .0005). A significantly greater number of male patients with free fluid had a surgical condition identified on imaging (57.4% versus 25%; P < .001). Children with free fluid and an associated condition on imaging were more likely to have surgery (94.4% versus 6.3%; P < .001). We found clinical outcomes (surgical versus nonsurgical) to be most correlated with a surgical diagnosis on diagnostic imaging and not with the amount of fluid present.

  2. Revisiting tuberculous pleurisy: pleural fluid characteristics and diagnostic yield of mycobacterial culture in an endemic area.

    PubMed

    Ruan, Sheng-Yuan; Chuang, Yu-Chung; Wang, Jann-Yuan; Lin, Jou-Wei; Chien, Jung-Yien; Huang, Chun-Ta; Kuo, Yao-Wen; Lee, Li-Na; Yu, Chong-Jen J

    2012-09-01

    Tuberculous pleurisy is traditionally indicated by extreme lymphocytosis in pleural fluid and low yield of effusion culture. However, there is considerable inconsistency among previous study results. In addition, these data should be updated due to early effusion studies and advances in culture methods. From January 2004 to June 2009, patients with tuberculous pleurisy were retrospectively identified from the mycobacteriology laboratories and the pathology and tuberculosis registration databases of two hospitals in Taiwan where tuberculosis is endemic. Pleural fluid characteristics and yields of mycobacterial cultures using liquid media were evaluated. A total of 382 patients with tuberculous pleurisy were identified. The median lymphocyte percentage of total cells in pleural fluids was 84% (IQR 64-95%) and 17% of cases had a lymphocyte percentage of <50%. The lymphocyte percentage was negatively associated with the probability of a positive effusion culture (OR 0.97; 95% CI 0.96 to 0.99). The diagnostic yields were 63% for effusion culture, 48% for sputum culture, 79% for the combination of effusion and sputum cultures, and 74% for histological examination of pleural biopsy specimens. The degree of lymphocyte predominance in tuberculous pleurisy was lower than was previously thought. The lymphocyte percentage in pleural fluid was negatively associated with the probability of a positive effusion culture. With the implementation of a liquid culture method, the sensitivity of effusion culture was much higher than has been previously reported, and the combination of effusion and sputum cultures provided a good diagnostic yield.

  3. Accuracy of stroke volume variation in predicting fluid responsiveness: a systematic review and meta-analysis.

    PubMed

    Zhang, Zhongheng; Lu, Baolong; Sheng, Xiaoyan; Jin, Ni

    2011-12-01

    Stroke volume variation (SVV) appears to be a good predictor of fluid responsiveness in critically ill patients. However, a wide range of its predictive values has been reported in recent years. We therefore undertook a systematic review and meta-analysis of clinical trials that investigated the diagnostic value of SVV in predicting fluid responsiveness. Clinical investigations were identified from several sources, including MEDLINE, EMBASE, WANFANG, and CENTRAL. Original articles investigating the diagnostic value of SVV in predicting fluid responsiveness were considered to be eligible. Participants included critically ill patients in the intensive care unit (ICU) or operating room (OR) who require hemodynamic monitoring. A total of 568 patients from 23 studies were included in our final analysis. Baseline SVV was correlated to fluid responsiveness with a pooled correlation coefficient of 0.718. Across all settings, we found a diagnostic odds ratio of 18.4 for SVV to predict fluid responsiveness at a sensitivity of 0.81 and specificity of 0.80. The SVV was of diagnostic value for fluid responsiveness in OR or ICU patients monitored with the PiCCO or the FloTrac/Vigileo system, and in patients ventilated with tidal volume greater than 8 ml/kg. SVV is of diagnostic value in predicting fluid responsiveness in various settings.

  4. [Diagnostic of ascites due to portal hypertension: accuracy of the serum-ascites albumin gradient and protein analises in ascitic fluid].

    PubMed

    Rodríguez Vargas, Brainy Omar; Monge Salgado, Eduardo; Montes Teves, Pedro; Salazar Ventura, Sonia; Guzmán Calderón, Edson

    2014-01-01

    To evaluate the diagnostic accuracy of the Serum-Ascites Albumin Gradient (GASA), Protein Concentration in the Ascitic Fluid (PTLA), Albumin Concentration in the ascitic fluid (CAA) and the Protein Ascites/Serum Ratio (IPAS) for the diagnosis of ascites due to portal hypertension. it was an observational and retrospective study of validation of diagnostic tests. The study population was patients from a National Public Health Hospital Daniel Alcides Carrion of Callao, Peru, during the period January to December of 2012, patients over 15 years old with a diagnosis of ascites which samples were taken for study by paracentesis with an standard technique, it was analyzed total protein and albumin, as well as study of total protein and albumin in blood. We obtained the diagnostic accuracy, sensitivity, specificity, PPV and NPV of the Serum-Ascites Albumin Gradient (GASA), Protein Concentration in the Ascitic Fluid (PTLA), Albumin Concentration in the ascitic fluid (CAA) and the Protein Ascites/Serum Ratio (IPAS) for the diagnosis of ascites due to portal hypertension. To determine ascites by HTP as diagnostic tests we took into account: GASA >= 1.1, PTLA <2.5, CAA <1.1 or IPAS< 0.5. There were 126 patients diagnosed with ascites, 10 patients was excluded for having incomplete data. Of the 116 patients, the average age was 53.03 +/- 15.73 years old, male 65 (56%) and female 51 (44%). 61 (52%) had ascites due to portal hypertension from liver cirrhosis, and 55 (48%) of ascites due to NO HTP. The sensitivity and specificity for GASA was 93% and 47% respectively, for PTLA was 80% and 89% respectively, for CAA was 85% and 87% respectively and for the IPAS was 83% and 80% respectively. The área under the ROC curve for GASA was 0.70, ATPL was 0.84, IPAS was 0.81 and CAA was 0.86, we found statistically significant differences between GASA compared to the other three parameters (p<0.01 ). The diagnostic accuracy of CAA, ATPL and IPAS is higher than the GASA to discriminate between ascites due to HTP or NO HTP, so that they could be used in clinical practice alone or together to achieve a diagnostic approach more successful.

  5. Evaluation of diagnostic value of four tumor markers in bronchoalveolar lavage fluid of peripheral lung cancer.

    PubMed

    Li, Jian; Chen, Ping; Mao, Chao-Ming; Tang, Xing-Ping; Zhu, Li-Rong

    2014-06-01

    The diagnostic role of carcinoembryonic antigen (CEA), squamous cell carcinoma (SCC) antigen, Cyfra 21-1 and neuron-specific enolase (NSE) in the bronchoalveolar lavage fluid (BALF) for lung cancer is still controversial. The aim of this study was to evaluate the diagnostic value of these four tumor markers in BALF for peripheral lung cancer. We measured and compared the levels of CEA, SCC, Cyfra21-1 and NSE in BALF in 42 patients with peripheral lung cancer and 22 patients with benign lung disease. In the patients with peripheral lung cancer, the BAL was separately performed in the bronchus of the tumor-bearing lung and in the corresponding bronchus of the opposite healthy lung. The levels of CEA, SCC, Cyfra21-1 and NSE were significantly elevated in BALF from the tumor-bearing lung compared with the opposite healthy lung in the lung cancer patients (P < 0.001) or the benign lung disease patients (P < 0.005). The diagnostic sensitivities of Cyfra21-1 (86 and 76%), with a specificity of 91%, were the highest among the four tumor markers for the tumor-bearing lung versus the opposite healthy lung and benign lung disease. The combination of Cyfra21-1 and CEA increased the sensitivity to 93 and 86 percent, respectively. The assay of these tumor markers in BALF may be used as a diagnostic tool to complement a cytological examination in the diagnosis of peripheral lung cancer. © 2013 Wiley Publishing Asia Pty Ltd.

  6. Update on pancreatic cyst fluid analysis

    PubMed Central

    Rockacy, Matthew; Khalid, Asif

    2013-01-01

    Pancreatic cystic lesions (PCL) may be incidentally detected in up to 13.5% of patients. These represent a wide variety of lesions including mucinous cysts [intraductal papillary mucinous neoplasms (IPMN) and mucinous cystic neoplasms (MCN)] that have malignant potential. The difficulty in identifying the various PCL and their unpredictable potential for malignant degeneration makes their management cumbersome. The current diagnostic evaluation of PCL often includes EUS-guided fine needle aspiration (EUS-FNA) for cyst fluid analysis. Cyst fluid can be analyzed for tumor markers, cytology, mucins, DNA analysis and amylase. Pancreatic cyst CEA level is considered the most accurate tumor marker for diagnosing mucinous cysts. Approximately 0.2 to 1.0 mL of cyst fluid is required to run the test and a cut-off of 192 ng/ mL can be expected to capture ~75% of mucinous cysts. The presence of a KRAS mutation is very specific for a mucinous cyst but lacks sensitivity. Cytology is especially helpful in diagnosing malignancy typically in the presence of a solid component in the cyst. Newer markers to improve diagnostic accuracy are on the horizon, but clinical studies are awaited. PMID:24714589

  7. Evaluation of pyramid training as a method to increase diagnostic sampling capacity during an emergency veterinary response to a swine disease outbreak.

    PubMed

    Canon, Abbey J; Lauterbach, Nicholas; Bates, Jessica; Skoland, Kristin; Thomas, Paul; Ellingson, Josh; Ruston, Chelsea; Breuer, Mary; Gerardy, Kimberlee; Hershberger, Nicole; Hayman, Kristen; Buckley, Alexis; Holtkamp, Derald; Karriker, Locke

    2017-06-15

    OBJECTIVE To develop and evaluate a pyramid training method for teaching techniques for collection of diagnostic samples from swine. DESIGN Experimental trial. SAMPLE 45 veterinary students. PROCEDURES Participants went through a preinstruction assessment to determine their familiarity with the equipment needed and techniques used to collect samples of blood, nasal secretions, feces, and oral fluid from pigs. Participants were then shown a series of videos illustrating the correct equipment and techniques for collecting samples and were provided hands-on pyramid-based instruction wherein a single swine veterinarian trained 2 or 3 participants on each of the techniques and each of those participants, in turn, trained additional participants. Additional assessments were performed after the instruction was completed. RESULTS Following the instruction phase, percentages of participants able to collect adequate samples of blood, nasal secretions, feces, and oral fluid increased, as did scores on a written quiz assessing participants' ability to identify the correct equipment, positioning, and procedures for collection of samples. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that the pyramid training method may be a feasible way to rapidly increase diagnostic sampling capacity during an emergency veterinary response to a swine disease outbreak.

  8. [The development of a finger joint phantom for the optical simulation of early inflammatory rheumatic changes].

    PubMed

    Prapavat, V; Runge, W; Mans, J; Krause, A; Beuthan, J; Müller, G

    1997-11-01

    In the field of rheumatology, conventional diagnostic methods permit the detection only of advanced stages of the disease, which is at odds with the current clinical demand for the early diagnosis of inflammatory rheumatic diseases. Prompted by current needs, we developed a finger joint phantom that enables the optical and geometrical simulation of an early stage of rheumatoid arthritis (RA). The results presented here form the experimental basis for an evaluation of new RA diagnostic systems based on near infrared light. The early stage of RA is characterised mainly by a vigorous proliferation of the synovial membrane and clouding of the synovial fluid. Using a double-integrating-sphere technique, the absorption and scattering coefficients (mua, mus') are experimentally determined for healthy and pathologically altered synovial fluid and capsule tissue. Using a variable mixture of Intralipid Indian ink and water as a scattering/absorption medium, the optical properties of skin, synovial fluid or capsule can be selected individually. Since the optical and geometrical properties of bone tissue remain constant in early-stage RA, a solid material is used for its simulation. Using the finger joint phantom described herein, the optical properties of joint regions can be adjusted specifically, enabling an evaluation of their effects on an optical signal--for example, during fluorography--and the investigation of these effects for diagnostically useful information. The experimental foundation for the development of a new optical system for the early diagnosis of RA has now been laid.

  9. Pre-cut Filter Paper for Detecting Anti-Japanese Encephalitis Virus IgM from Dried Cerebrospinal Fluid Spots

    PubMed Central

    Bharucha, Tehmina; Chanthongthip, Anisone; Phuangpanom, Soumphou; Phonemixay, Ooyanong; Sengvilaipaseuth, Onanong; Vongsouvath, Manivanh; Lee, Sue; Newton, Paul N.; Dubot-Pérès, Audrey

    2016-01-01

    Background The use of filter paper as a simple, inexpensive tool for storage and transportation of blood, ‘Dried Blood Spots’ or Guthrie cards, for diagnostic assays is well-established. In contrast, there are a paucity of diagnostic evaluations of dried cerebrospinal fluid (CSF) spots. These have potential applications in low-resource settings, such as Laos, where laboratory facilities for central nervous system (CNS) diagnostics are only available in Vientiane. In Laos, a major cause of CNS infection is Japanese encephalitis virus (JEV). We aimed to develop a dried CSF spot protocol and to evaluate its diagnostic performance using the World Health Organisation recommended anti-JEV IgM antibody capture enzyme-linked immunosorbent assay (JEV MAC-ELISA). Methodology and Principal Findings Sample volumes, spotting techniques and filter paper type were evaluated using a CSF-substitute of anti-JEV IgM positive serum diluted in Phosphate Buffer Solution (PBS) to end-limits of detection by JEV MAC-ELISA. A conventional protocol, involving eluting one paper punch in 200μl PBS, did not detect the end-dilution, nor did multiple punches utilising diverse spotting techniques. However, pre-cut filter paper enabled saturation with five times the volume of CSF-substitute, sufficiently improving sensitivity to detect the end-dilution. The diagnostic accuracy of this optimised protocol was compared with routine, neat CSF in a pilot, retrospective study of JEV MAC-ELISA on consecutive CSF samples, collected 2009–15, from three Lao hospitals. In comparison to neat CSF, 132 CSF samples stored as dried CSF spots for one month at 25–30°C showed 81.6% (65.7–92.3 95%CI) positive agreement, 96.8% (91.0–99.3 95%CI) negative agreement, with a kappa coefficient of 0.81 (0.70–0.92 95%CI). Conclusions/Significance The novel design of pre-cut filter paper saturated with CSF could provide a useful tool for JEV diagnostics in settings with limited laboratory access. It has the potential to improve national JEV surveillance and inform vaccination policies. The saturation of filter paper has potential use in the wider context of pathogen detection, including dried spots for detecting other analytes in CSF, and other body fluids. PMID:26986061

  10. Comparison of refractometry and biuret assay for measurement of total protein concentration in canine abdominal and pleural fluid specimens.

    PubMed

    Rose, Alexandra; Funk, Deborah; Neiger, Reto

    2016-04-01

    To compare total protein (TP) concentrations in canine pleural and abdominal fluid specimens as measured by refractometry and biuret assay. Diagnostic test evaluation. Data regarding 92 pleural and 148 abdominal fluid specimens from dogs with various diseases. TP concentrations in fluid specimens as measured by refractometry and biuret assay were recorded. Strength of association between sets of measurements was assessed by Spearman rank correlations and Bland-Altman plots. Optimal concentration cutoff for diagnostic discrimination between exudate and nonexudate was identified by construction of receiver operating characteristic curves. Median TP concentration in pleural fluid specimens was 2.7 g/dL (range, 0.3 to 4.8 g/dL) for refractometry and 2.9 g/dL (range, 0.7 to 5.8 g/dL) for biuret assay. Median TP concentration in abdominal fluid specimens was 3.5 g/dL (range, 0.1 to 6.0 g/dL) for refractometry and 3.5 g/dL (range, 0.6 to 5.7 g/dL) for biuret assay. Correlation was significant between refractometric and biuret results for pleural (ρ = 0.921) and abdominal (ρ = 0.908) fluid. Bland-Altman plots revealed bias of -0.18 g/dL for pleural fluid and -0.03 g/dL for abdominal fluid for refractometry versus biuret assay. With a TP concentration of ≥ 3 g/dL used to distinguish exudate from nonexudate, sensitivity of refractometry was 77% for pleural fluid and 80% for abdominal fluid. Specificity was 100% and 94%, respectively. Refractometry yielded acceptable results for measurement of TP concentration in canine pleural and abdominal fluid specimens, providing a more rapid and convenient method than biuret assay.

  11. Revisiting tuberculous pleurisy: pleural fluid characteristics and diagnostic yield of mycobacterial culture in an endemic area

    PubMed Central

    Ruan, Sheng-Yuan; Chuang, Yu-Chung; Lin, Jou-Wei; Chien, Jung-Yien; Huang, Chun-Ta; Kuo, Yao-Wen; Lee, Li-Na; Yu, Chong-Jen J

    2012-01-01

    Background Tuberculous pleurisy is traditionally indicated by extreme lymphocytosis in pleural fluid and low yield of effusion culture. However, there is considerable inconsistency among previous study results. In addition, these data should be updated due to early effusion studies and advances in culture methods. Methods From January 2004 to June 2009, patients with tuberculous pleurisy were retrospectively identified from the mycobacteriology laboratories and the pathology and tuberculosis registration databases of two hospitals in Taiwan where tuberculosis is endemic. Pleural fluid characteristics and yields of mycobacterial cultures using liquid media were evaluated. Results A total of 382 patients with tuberculous pleurisy were identified. The median lymphocyte percentage of total cells in pleural fluids was 84% (IQR 64–95%) and 17% of cases had a lymphocyte percentage of <50%. The lymphocyte percentage was negatively associated with the probability of a positive effusion culture (OR 0.97; 95% CI 0.96 to 0.99). The diagnostic yields were 63% for effusion culture, 48% for sputum culture, 79% for the combination of effusion and sputum cultures, and 74% for histological examination of pleural biopsy specimens. Conclusion The degree of lymphocyte predominance in tuberculous pleurisy was lower than was previously thought. The lymphocyte percentage in pleural fluid was negatively associated with the probability of a positive effusion culture. With the implementation of a liquid culture method, the sensitivity of effusion culture was much higher than has been previously reported, and the combination of effusion and sputum cultures provided a good diagnostic yield. PMID:22436167

  12. [Long-term prognosis of idiopathic chronic adult hydrocephalus: I. The University Hospital Marqués de Valdecilla diagnostic and therapeutic protocol].

    PubMed

    Martín-Láez, Rubén; Vázquez-Barquero, Alfonso

    Despite the existence of published guidelines for more than a decade, there is still a substantial variation in the management of idiopathic normal pressure hydrocephalus due to its diagnostic and therapeutic complexity. The diagnostic and therapeutic protocol for the management of idiopathic normal pressure hydrocephalus in use at the Department of Neurosurgery of the University Hospital Marqués de Valdecilla is presented. The diagnostic process includes neuropsychological testing, phase contrast cine MRI, urodynamic evaluation, continuous intracranial pressure monitoring, cerebrospinal fluid hydrodynamics by means of lumbar infusion testing, and intra-abdominal pressure measurement. A patient is considered a surgical candidate if any of the following criteria is met: mean intracranial pressure >15mmHg, or B-waves present in >10% of overnight recording; pressure-volume index <15ml, or resistance to cerebrospinal fluid outflow (R OUT ) >4.5mmHg/ml/min in bolus infusion test; R OUT >12mmHg/ml/min, intracranial pressure >22mmHg, or high amplitude B-waves in the steady-state of the continuous rate infusion test; or a clinical response to high-volume cerebrospinal fluid withdrawal. The implementation of a diagnostic and therapeutic protocol for idiopathic normal pressure hydrocephalus management could improve various aspects of patient care. It could reduce variability in clinical practice, optimise the use of health resources, and help in identifying scientific uncertainty areas, in order to direct research efforts in a more appropriate way. Copyright © 2016 Sociedad Española de Neurocirugía. Publicado por Elsevier España, S.L.U. All rights reserved.

  13. Predictive Role of ADA in Bronchoalveolar Lavage Fluid in Making the Diagnosis of Pulmonary Tuberculosis.

    PubMed

    Binesh, Fariba; Halvani, Abolhassan

    2013-01-01

    Current diagnostic tests for tuberculosis (TB) are time-consuming. The aim of this study was to evaluate the diagnostic usefulness of ADA in bronchoalveolar lavage fluid in patients with pulmonary TB. A cross-sectional study was performed in Yazd, Iran, between 2009 and 2010. Patients suspected of pulmonary TB with negative sputum smear for AFB were included in the study. Mean ADA levels in BAL fluids were measured and compared between study groups. Sixty-three patients were enrolled in the study among which 15 cases had pulmonary TB, 33 had pulmonary diseases other than TB, and 15 subjects with normal bronchoscopy results were considered as controls. Mean ADA levels in BAL fluid were 4.13 ± 2.55, 2.42 ± 1.06, and 1.93 ± 0.88, respectively. This rate was significantly higher in the pulmonary TB group compared to the other two groups (P = 0.001). Using ROC curve with a cut-off value of 3.5 IU/L, the highest sensitivity (57%) and specificity (84%) were obtained in diagnosis of TB. The results showed that although ADA activity in BAL fluid of pulmonary TB patients was higher than those seen in other diseases, a negative test does not rule out pulmonary TB.

  14. Metastatic carcinoma presenting as hind-limb lameness: diagnosis by synovial fluid cytology.

    PubMed

    Meinkoth, J H; Rochat, M C; Cowell, R L

    1997-01-01

    A dog presented for evaluation of left hind-limb lameness and pain associated with manipulation of the tail. Synovial metastasis of a carcinoma was diagnosed by joint fluid examination. A primary bronchiolar-alveolar carcinoma with widespread (including synovial and skeletal) metastases was diagnosed on postmortem examination. Metastasis to synovial surfaces is uncommon, but when it occurs, the metastasis-induced arthritis may be the initial presenting complaint for which medical attention is sought. Although rarely reported, cytological examination of synovial fluid may be diagnostic. This paper presents an interesting clinical case and reviews the literature concerning metastatic disease of the synovium.

  15. Diagnostic value of ex vivo pleural fluid interferon-gamma versus adapted whole-blood quantiferon-TB gold in tube assays in tuberculous pleural effusion

    PubMed Central

    Eldin, Eman N.; Omar, Asmaa; Khairy, Mahmoud; Mekawy, Adel H. M.; Ghanem, Maha K.

    2012-01-01

    BACKGROUND: Noninvasive diagnosis of pleural tuberculosis (TB) remains a challenge due to the paucibacillary nature of the disease. As Mycobacterium tuberculosis (MTB)-specific T cells are recruited into pleural space in TB effusion; their indirect detection may provide useful clinical information. OBJECTIVES: Evaluation of pleural fluid interferon (INF)-γ levels vs Quantiferon–TB Gold In tube assay (QFT- IT) in blood and its adapted variants, using pleural fluid or isolated pleural fluid cells in the diagnosis of pleural TB. METHODS: Thirty-eight patients with pleural effusion of unknown etiology presented at Assiut University Hospital, Egypt, were recruited. Blood and pleural fluid were collected at presentation for INF-γ assays. Ex vivo pleural fluid INF-γ levels, QFT-IT in blood and its adapted variants were compared with final diagnosis as confirmed by other tools including blind and/or thoracoscopic pleural biopsy. RESULTS: The final clinical diagnosis was TB in 20 (53%), malignancy in 10 (26%), and effusion due to other causes in eight patients (21%). Ex vivo pleural fluid INF-γ levels accurately identified TB in all patients and were superior to the QFT-IT assays using blood or pleural fluid (70 and 78% sensitivity, with 60 and 83% specificity, respectively). QFT-IT assay applied to isolated pleural fluid cells had 100% sensitivity and 72% specificity. The optimal cut-off obtained with ROC analysis was 0.73 for TB Gold assay in blood assay, 0.82 IU/ml for the cultured pleural fluid assay, and 0.94 for isolated pleural cells assay. CONCLUSION: The ex vivo pleural fluid INF-γ level is an accurate marker for the diagnosis of pleural TB. QFT- IT assay in peripheral blood or its adapted versions of the assay using pleural fluid and/or washed pleural fluid cells had no diagnostic advantage over pleural fluid INF-γ in the diagnosis of pleural TB. PMID:23189099

  16. Characterization and Comparison of Galactomannan Enzyme Immunoassay and Quantitative Real-Time PCR Assay for Detection of Aspergillus fumigatus in Bronchoalveolar Lavage Fluid from Experimental Invasive Pulmonary Aspergillosis

    PubMed Central

    Francesconi, Andrea; Kasai, Miki; Petraitiene, Ruta; Petraitis, Vidmantas; Kelaher, Amy M.; Schaufele, Robert; Hope, William W.; Shea, Yvonne R.; Bacher, John; Walsh, Thomas J.

    2006-01-01

    Bronchoalveolar lavage (BAL) is widely used for evaluation of patients with suspected invasive pulmonary aspergillosis (IPA). However, the diagnostic yield of BAL for detection of IPA by culture and direct examination is limited. Earlier diagnosis may be facilitated by assays that can detect Aspergillus galactomannan antigen or DNA in BAL fluid. We therefore characterized and compared the diagnostic yields of a galactomannan enzyme immunoassay (GM EIA), quantitative real-time PCR (qPCR), and quantitative cultures in experiments using BAL fluid from neutropenic rabbits with experimentally induced IPA defined as microbiologically and histologically evident invasion. The qPCR assay targeted the rRNA gene complex of Aspergillus fumigatus. The GM EIA and qPCR assay were characterized by receiver operator curve analysis. With an optimal cutoff of 0.75, the GM EIA had a sensitivity and specificity of 100% in untreated controls. A decline in sensitivity (92%) was observed when antifungal therapy (AFT) was administered. The optimal cutoff for qPCR was a crossover of 36 cycles, with sensitivity and specificity of 80% and 100%, respectively. The sensitivity of qPCR also decreased with AFT to 50%. Quantitative culture of BAL had a sensitivity of 46% and a specificity of 100%. The sensitivity of quantitative culture decreased with AFT to 16%. The GM EIA and qPCR assay had greater sensitivity than culture in detection of A. fumigatus in BAL fluid in experimentally induced IPA (P ± 0.04). Use of the GM EIA and qPCR assay in conjunction with culture-based diagnostic methods applied to BAL fluid could facilitate accurate diagnosis and more-timely initiation of specific therapy. PMID:16825367

  17. Diagnosis of tuberculous pleurisy with combination of adenosine deaminase and interferon-γ immunospot assay in a tuberculosis-endemic population: A prospective cohort study.

    PubMed

    Xu, Han-Yan; Li, Cheng-Ye; Su, Shan-Shan; Yang, Li; Ye, Min; Ye, Jun-Ru; Ke, Pei-Pei; Chen, Cheng-Shui; Xie, Yu-Peng; Li, Yu-Ping

    2017-11-01

    The aim of this study was to identify the optimal cut-off value of T cell enzyme-linked immunospot assay for tuberculosis (T-SPOT.TB) and evaluate its diagnostic performance alone (in the peripheral blood) or in combination with the adenosine deaminase (ADA) activity test (in peripheral blood and the pleural fluid) in patients with tuberculous pleurisy.Adult patients presenting with pleural effusion were included in this prospective cohort study. Tuberculous pleurisy was diagnosed by T-SPOT.TB in peripheral blood and a combination of T-SPOT.TB and ADA activity test in pleural fluid and peripheral blood. Receiver operating characteristic (ROC) curve in combination with multivariate logistic regression was used to evaluate the diagnostic performance of the assays.Among a total of 189 patients with suspected tuberculous pleurisy who were prospectively enrolled in this study, 177 patients were validated for inclusion in the final analysis. ROC analysis revealed that the area under the ROC curve (AUC) for T-SPOT.TB in pleural fluid and peripheral blood was 0.918 and 0.881, respectively, and for the ADA activity test in pleural fluid was 0.944. In addition, 95.5 spot-forming cells (SFCs)/2.5 × 10 cells were determined as the optimal cut-off value for T-SPOT.TB in pleural fluid. Parallel combination of T-SPOT.TB and ADA activity test in pleural fluid showed increased sensitivity (96.9%) and specificity (87.5%), whereas serial combination showed increased specificity (97.5%). The combination of 3 assays had the highest sensitivity at 97.9%, with an AUC value of 0.964.T-SPOT.TB in pleural fluid performed better than that in peripheral blood and the ADA activity test in pleural fluid for tuberculous pleurisy diagnosis. The optimal cut-off value of T-SPOT.TB in pleural fluid was 95.5 SFCs/2.5 × 10 cells. Combination of 3 assays might be a promising approach for tuberculous pleurisy diagnosis. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.

  18. Diagnosis of tuberculous pleurisy with combination of adenosine deaminase and interferon-γ immunospot assay in a tuberculosis-endemic population

    PubMed Central

    Xu, Han-Yan; Li, Cheng-Ye; Su, Shan-Shan; Yang, Li; Ye, Min; Ye, Jun-Ru; Ke, Pei-Pei; Chen, Cheng-Shui; Xie, Yu-Peng; Li, Yu-Ping

    2017-01-01

    Abstract The aim of this study was to identify the optimal cut-off value of T cell enzyme-linked immunospot assay for tuberculosis (T-SPOT.TB) and evaluate its diagnostic performance alone (in the peripheral blood) or in combination with the adenosine deaminase (ADA) activity test (in peripheral blood and the pleural fluid) in patients with tuberculous pleurisy. Adult patients presenting with pleural effusion were included in this prospective cohort study. Tuberculous pleurisy was diagnosed by T-SPOT.TB in peripheral blood and a combination of T-SPOT.TB and ADA activity test in pleural fluid and peripheral blood. Receiver operating characteristic (ROC) curve in combination with multivariate logistic regression was used to evaluate the diagnostic performance of the assays. Among a total of 189 patients with suspected tuberculous pleurisy who were prospectively enrolled in this study, 177 patients were validated for inclusion in the final analysis. ROC analysis revealed that the area under the ROC curve (AUC) for T-SPOT.TB in pleural fluid and peripheral blood was 0.918 and 0.881, respectively, and for the ADA activity test in pleural fluid was 0.944. In addition, 95.5 spot-forming cells (SFCs)/2.5 × 105 cells were determined as the optimal cut-off value for T-SPOT.TB in pleural fluid. Parallel combination of T-SPOT.TB and ADA activity test in pleural fluid showed increased sensitivity (96.9%) and specificity (87.5%), whereas serial combination showed increased specificity (97.5%). The combination of 3 assays had the highest sensitivity at 97.9%, with an AUC value of 0.964. T-SPOT.TB in pleural fluid performed better than that in peripheral blood and the ADA activity test in pleural fluid for tuberculous pleurisy diagnosis. The optimal cut-off value of T-SPOT.TB in pleural fluid was 95.5 SFCs/2.5 × 105 cells. Combination of 3 assays might be a promising approach for tuberculous pleurisy diagnosis. PMID:29381918

  19. Focused Assessment with Sonography for Trauma in weightlessness: a feasibility study

    NASA Technical Reports Server (NTRS)

    Kirkpatrick, Andrew W.; Hamilton, Douglas R.; Nicolaou, Savvas; Sargsyan, Ashot E.; Campbell, Mark R.; Feiveson, Alan; Dulchavsky, Scott A.; Melton, Shannon; Beck, George; Dawson, David L.

    2003-01-01

    BACKGROUND: The Focused Assessment with Sonography for Trauma (FAST) examines for fluid in gravitationally dependent regions. There is no prior experience with this technique in weightlessness, such as on the International Space Station, where sonography is currently the only diagnostic imaging tool. STUDY DESIGN: A ground-based (1 g) porcine model for sonography was developed. We examined both the feasibility and the comparative performance of the FAST examination in parabolic flight. Sonographic detection and fluid behavior were evaluated in four animals during alternating weightlessness (0 g) and hypergravity (1.8 g) periods. During flight, boluses of fluid were incrementally introduced into the peritoneal cavity. Standardized sonographic windows were recorded. Postflight, the video recordings were divided into 169 20-second segments for subsequent interpretation by 12 blinded ultrasonography experts. Reviewers first decided whether a video segment was of sufficient diagnostic quality to analyze (determinate). Determinate segments were then analyzed as containing or not containing fluid. A probit regression model compared the probability of a positive fluid diagnosis to actual fluid levels (0 to 500 mL) under both 0-g and 1.8-g conditions. RESULTS: The in-flight sonographers found real-time scanning and interpretation technically similar to that of terrestrial conditions, as long as restraint was maintained. On blinded review, 80% of the recorded ultrasound segments were considered determinate. The best sensitivity for diagnosis in 0 g was found to be from the subhepatic space, with probability of a positive fluid diagnosis ranging from 9% (no fluid) to 51% (500 mL fluid). CONCLUSIONS: The FAST examination is technically feasible in weightlessness, and merits operational consideration for clinical contingencies in space.

  20. Differentiation between malignant and non-malignant pleural effusion using cancer ratio and other new parameters.

    PubMed

    Korczynski, Piotr; Mierzejewski, Michal; Krenke, Rafal; Safianowska, Aleksandra; Light, Richard W

    2018-06-05

    Introduction In contrast to tuberculous pleurisy (TP), no accurate and commonly accepted biochemical marker of malignant pleural effusion (MPE) has been established. Objectives We aimed to: 1) evaluate the ability of previously reported cancer ratio (CR) to discriminate MPEs and non-MPEs, 2) test whether age may have additional value in differentiating MPEs and non MPEs, and if so, 3) to combine LDH and age with other TP biomarkers in search of an index useful in the identification of MPE. Patients and methods A retrospective analysis of data from 140 patients with malignant (n=74), tuberculous (n=37) and parapneumonic (n=29) pleural effusions was performed. The diagnostic performance of a test to discriminate between MPEs and non-MPEs was evaluated using Receiver Operating Characteristic. Results Three ratios showed the largest AUC: serum LDH/pleural fluid soluble Fas ligand, age/pleural fluid ADA and serum LDH/pleural fluid IL-18 and were characterized by a high sensitivity (95, 93.2, 92.9% respectively) and fair specificity (64.8, 71.2, 58.5% respectively) in discrimination MPE from non-MPEs. AUC for CR was lower than for aforementioned values and showed 94.6% sensitivity and 68.2% specificity. Conclusions Our study showed a lower specificity of CR in discriminating MPEs and non-MPEs than previously reported. We demonstrated that combinations of serum LDH with other pleural fluid biomarkers of TP have a similar diagnostic performance. We also found that age might be an important factor differentiating between MPEs and non-MPEs and propose a new age/pleural fluid ADA ratio which has a discriminative potential similar to that of CR.

  1. Clinical and diagnostic utility of saliva as a non-invasive diagnostic fluid:
a systematic review

    PubMed Central

    Nunes, Lazaro Alessandro Soares; Mussavira, Sayeeda

    2015-01-01

    This systematic review presents the latest trends in salivary research and its applications in health and disease. Among the large number of analytes present in saliva, many are affected by diverse physiological and pathological conditions. Further, the non-invasive, easy and cost-effective collection methods prompt an interest in evaluating its diagnostic or prognostic utility. Accumulating data over the past two decades indicates towards the possible utility of saliva to monitor overall health, diagnose and treat various oral or systemic disorders and drug monitoring. Advances in saliva based systems biology has also contributed towards identification of several biomarkers, development of diverse salivary diagnostic kits and other sensitive analytical techniques. However, its utilization should be carefully evaluated in relation to standardization of pre-analytical and analytical variables, such as collection and storage methods, analyte circadian variation, sample recovery, prevention of sample contamination and analytical procedures. In spite of all these challenges, there is an escalating evolution of knowledge with the use of this biological matrix. PMID:26110030

  2. Human Chorionic Gonadotropine in Cul-de-sac Fluid in Tubal Ectopic Pregnacy; A New Diagnostic Approach.

    PubMed

    Karahasanoglu, Ayse; Uzun, Isil; Ozdemir, Mucize; Yazicioglu, Fehmi

    2016-04-01

    Although new diagnostic abilities are being utilised increasingly yet early detection of tubal pregnancy remains a challenge. The use of highly sensitive hCG kits has facilitated the early diagnosis of a pregnancy. But it takes time to determine the localisation of the pregnancy. Early diagnosis of ectopic pregnancy may reduce the morbidity of ectopic pregnancy. This study was conducted to analyse the cul-de-sac and serum βhCG ratio in tubal ectopic pregnancy cases which may be a new diagnostic approach for ectopic pregnancy. Between January 2004 and July 2011, 263 patients with ectopic pregnancy were included in the study. Risk factors of patients and treatment modalities were evaluated. hCG was measured in peripheral serum and peritoneal fluid, obtained by puncture of Douglas pouch in 52 patients with tubal ectopic pregnancy. hCG level was determined in the cul-de-sac fluid and in the maternal serum for comparison. Tubectomy (5.3%), history of abortion (9.5%), history of previous surgery (14.8%), previous cesarean section (8%) and pelvic infamatorry disease (15.9 %) were the important risk factors for ectopic pregnancy in our cases. In 51 of 52 patients with tubal pregnancy, the cul-de-sac hCG vaule and the serum hCG value ratio was >1. It is concluded that the ratio of hCG in cul-de -sac and serum can be used for the verification of tubal ectopic pregnancy in addition to other diagnostic methods. This may help rapid confirmation of the diagnosis of ectopic pregnancy.

  3. Periprosthetic joint infections: a clinical practice algorithm.

    PubMed

    Volpe, Luigi; Indelli, Pier Francesco; Latella, Leonardo; Poli, Paolo; Yakupoglu, Jale; Marcucci, Massimiliano

    2014-01-01

    periprosthetic joint infection (PJI) accounts for 25% of failed total knee arthroplasties (TKAs) and 15% of failed total hip arthroplasties (THAs). The purpose of the present study was to design a multidisciplinary diagnostic algorithm to detect a PJI as cause of a painful TKA or THA. from April 2010 to October 2012, 111 patients with suspected PJI were evaluated. The study group comprised 75 females and 36 males with an average age of 71 years (range, 48 to 94 years). Eighty-four patients had a painful THA, while 27 reported a painful TKA. The stepwise diagnostic algorithm, applied in all the patients, included: measurement of serum C-reactive protein (CRP) and erythrocyte sedimentation rate (ESR) levels; imaging studies, including standard radiological examination, standard technetium-99m-methylene diphosphonate (MDP) bone scan (if positive, confirmation by LeukoScan was obtained); and joint aspiration with analysis of synovial fluid. following application of the stepwise diagnostic algorithm, 24 out of our 111 screened patients were classified as having a suspected PJI (21.7%). CRP and ESR levels were negative in 84 and positive in 17 cases; 93.7% of the patients had a positive technetium-labeled bone scan, and 23% a positive LeukoScan. Preoperative synovial fluid analysis was positive in 13.5%; analysis of synovial fluid obtained by preoperative aspiration showed a leucocyte count of > 3000 cells μ/l in 52% of the patients. the present study showed that the diagnosis of PJI requires the application of a multimodal diagnostic protocol in order to avoid complications related to surgical revision of a misdiagnosed "silent" PJI. Level IV, therapeutic case series.

  4. KRAS mutation analysis of washing fluid from endoscopic ultrasound-guided fine needle aspiration improves cytologic diagnosis of pancreatic ductal adenocarcinoma.

    PubMed

    Park, Joo Kyung; Lee, Yoon Jung; Lee, Jong Kyun; Lee, Kyu Taek; Choi, Yoon-La; Lee, Kwang Hyuck

    2017-01-10

    EUS-FNA becomes one of the most important diagnostic modalities for PDACs. However, acquired tissue specimens were sometimes insufficient to make a definite cytological diagnosis. On the other hand, KRAS mutation is the most frequently acquired genetic alteration found more than 90% of PDACs. To investigate the way to improve diagnostic accuracy for PDACs using both cytological examination and KRAS mutation analysis would be a great help. Therefore, the aims of this study were to evaluate usefulness of conventional cytological examination combined with KRAS mutation analysis with modified PCR technology to improve the sensitivity and the accuracy. We enrolled 43 patients with solid pancreatic masses and 86 EUS-FNA specimens were obtained. During the EUS-FNA, the needle catheter was flushed with 2 cc of saline and the washed fluid was collected for KRAS mutation analysis for the first 2 passes; PNAClamp™ KRAS Mutation Detection Kit. There were 46 specimens from the 23 PDACs and 40 specimens from the 20 other pancreatic diseases. The sensitivity, specificity and accuracy were as follows; conventional cytopathologic examination: 63%, 100% and 80%; combination of cytopathologic examination and K-ras mutation analysis: 87%, 100% and 93%. Furthermore, KRAS mutation was detected 11 out of 17 PDAC samples whose cytopathology results were inconclusive. KRAS mutation analysis with PNAClamp™ technique using washing fluid from EUS-FNA along with cytological examination may not only improve the diagnostic accuracy of PDACs, but also establish the platform using genetic analysis which would be helpful as diagnostic modality for PDACs.

  5. Point-of-care oral-based diagnostics

    PubMed Central

    Hart, RW; Mauk, MG; Liu, C; Qiu, X; Thompson, JA; Chen, D; Malamud, D; Abrams, WR; Bau, HH

    2014-01-01

    Many of the target molecules that reside in blood are also present in oral fluids, albeit at lower concentrations. Oral fluids are, however, relatively easy and safe to collect without the need for specialized equipment and training. Thus, oral fluids provide convenient samples for medical diagnostics. Recent advances in lab-on-a-chip technologies have made minute, fully integrated diagnostic systems practical for an assortment of point-of-care tests. Such systems can perform either immunoassays or molecular diagnostics outside centralized laboratories within time periods ranging from minutes to an hour. The article briefly reviews recent advances in devices for point-of-care testing with a focus on work that has been carried out by the authors as part of a NIH program. PMID:21521419

  6. The diagnostic value of cerebrospinal fluid lactate for post-neurosurgical bacterial meningitis: a meta-analysis.

    PubMed

    Xiao, Xiong; Zhang, Yang; Zhang, Liwei; Kang, Peng; Ji, Nan

    2016-09-13

    Bacterial meningitis is not rare in post-neurosurgical patients. If patients are not treated promptly, the mortality rate can reach 20 to 50 %. The concentration of cerebrospinal fluid (CSF) lactate has been reported to be helpful in the diagnosis of bacterial meningitis; however, no systematic evaluations have investigated CSF from a postoperative perspective. In this study, we performed a systematic evaluation and meta-analysis of the efficacy of using CSF lactate concentrations in the diagnosis of post-neurosurgical bacterial meningitis. We retrieved studies that investigated the diagnostic value of CSF lactate for the diagnosis of post-neurosurgical bacterial meningitis by searching PubMed, EBSCO, the Cochrane Library and ClinicalTrials.gov. All these databases were searched from inception to November 2015. We used Quality Assessment of Diagnostic Accuracy Studies (QUADAS), a tool for the quality assessment of diagnostic accuracy, to evaluate the quality of the included studies. The Meta-DiSc 1.4 and Review Manager 5.3 software programs were used to analyze the included studies. Forest plots and summary receiver operating characteristics (SROC) curves were also drawn. Five studies, involving a total of 404 post-neurosurgical patients, were selected from 1,672 articles according to the inclusion criteria. The quality of the five included studies was assessed using QUADAS, and the related results are presented in tables. The meta-analysis revealed the following diagnostic values regarding CSF lactate for post-neurosurgical bacterial meningitis: a pooled sensitivity of 0.92 (95 % CI 0.85-0.96), a pooled specificity of 0.88 (95 % CI 0.84-0.92 with significant heterogeneity), a diagnostic odds ratio of 83.09 (95 % CI 36.83-187.46), an area under the curve (AUCSROC) of 0.9601, an SE(AUC) of 0.0122, a Q* of 0.9046 and an SE(Q*) of 0.0179. The meta-analysis indicated that the CSF lactate concentration has relatively high sensitivity and specificity for the diagnosis of post-neurosurgical bacterial meningitis and thus has relatively good efficacy.

  7. Performance of Xpert MTB/RIF on Ascitic Fluid Samples for Detection of Abdominal Tuberculosis.

    PubMed

    Rufai, Syed Beenish; Singh, Sarman; Singh, Amit; Kumar, Parveen; Singh, Jitendra; Vishal, Anand

    2017-01-01

    Diagnosis of abdominal tuberculosis (TB) from ascitic fluid samples using routinely available diagnostic methods is challenging due to its paucibacillary nature. Although performance of Xpert MTB/RIF assay has been evaluated extensively on pulmonary samples, its performance on extrapulmonary samples is still under evaluation. The objective of this study was to find out the performance of Xpert MTB/RIF on ascitic fluid samples obtained from suspected cases of abdominal TB. Performance was compared with Mycobacterium growth indicator tube-960 (MGIT-960) culture and in-house multiplex polymerase chain reaction (PCR). The latter detects and differentiates Mycobacterium tuberculosis and nontuberculous mycobacteria simultaneously. Sixty-seven patients suspected of probable/possible abdominal TB were included in this observational, prospective study. All samples were tested by Ziehl-Neelsen staining, MGIT-960 culture, in-house multiplex PCR, and Xpert MTB/RIF assay. All 67 samples were smear negative. Seventeen (25.4%) were MGIT-960 culture positive while 12 (17.9%) were detected positive by the Xpert MTB/RIF assay and 9 (13.4%) by in-house multiplex PCR. Sensitivity and specificity of the Xpert MTB/RIF assay compared with the MGIT-960 culture were 70.6% (95%, confidence interval [CI]: 44.1-89.7) and 100% (95%, CI: 92.8-100) and that of in-house multiplex PCR were 52.9% (95%, CI: 30.9-73.8) and 100% (95%, CI: 92.8-100), respectively. Diagnostic yield of Xpert MTB/RIF assay on ascitic fluid samples was lower than MGIT-960 culture. We thus emphasize on the need for urgent discovery of new biomarkers for paucibacillary TB.

  8. Polymerase chain reaction-based detection of Pneumocystis jirovecii in bronchoalveolar lavage fluid for the diagnosis of pneumocystis pneumonia.

    PubMed

    Oren, Ilana; Hardak, Emilia; Finkelstein, Renato; Yigla, Mordechai; Sprecher, Hannah

    2011-09-01

    The diagnosis of pneumocystis pneumonia (PCP) in non-human immunodeficiency virus (HIV)-infected immunocompromised patients is notoriously difficult. The recent advent of polymerase chain reaction (PCR)-based detection systems, based on the identification of single fungal genes, has markedly improved diagnostic accuracy in this ominous disease. In an attempt to further improve diagnostic yield, the authors used a PCR-based detection system for Pneumocystis jirovecii, based on targeting 3 distinct genes. During the 4-year period (January 2005 to January 2009), all consecutive immunocompromised patients suspected of having PCP in the differential diagnosis underwent bronchoscopy with bronchoalveolar lavage sampling for the evaluation of the etiology of pulmonary infiltrates. Bronchoalveolar fluid was tested for the presence of a wide variety of possible etiological microorganisms. In a cohort of 214 immunocompromised patients (of which 198 were non-HIV immunocompromised patients) who underwent bronchoscopy with bronchoalveolar lavage for evaluation of pulmonary infiltrates, PCR correctly diagnosed PCP in 75% (42/56) compared with 14% (8/56) diagnosed by traditional stains, and increased diagnostic yield 5.4-fold. Given the absence of a sensitive gold standard, this study demonstrates the usefulness of a multigene PCR-based detection of Pneumocystis jirovecii DNA for supporting the clinical diagnosis of PCP, with high sensitivity and negative predictive value rates compared with direct stains, especially in non-HIV immunocompromised patients.

  9. Accuracy of different diagnostic tests for early, delayed and late prosthetic joint infection.

    PubMed

    Fernández-Sampedro, M; Fariñas-Alvarez, C; Garces-Zarzalejo, C; Alonso-Aguirre, M A; Salas-Venero, C; Martínez-Martínez, L; Fariñas, M C

    2017-08-25

    A combination of laboratory, histopathological and microbiological tests for diagnosis of prosthetic joint infection (PJI) have been strongly recommended. This study aims to characterize the accuracy of individual or group tests, such as culture of sonicate fluid, synovial fluid and peri-implant tissue, C-reactive protein (CRP) and histopathology for detection of early, delayed and late PJI. A prospective study of patients undergoing hip or knee arthroplasty from February 2009 to February 2014 was performed in a Spanish tertiary health care hospital. The diagnostic accuracy of the different methods was evaluated constructing receiver-operating-characteristic (ROC) curve areas. One hundred thirty consecutive patients were included: 18 (13.8%) early PJI, 35 (27%) delayed PJI and 77 (59.2%) late PJI. For individual parameters, the area under the ROC curve for peri-implant tissue culture was larger for early (0.917) than for delayed (0.829) and late PJI (0.778), p = 0.033. There was a significantly larger difference for ROC area in the synovial fluid culture for delayed (0.803) than for early (0.781) and late infections (0.679), p = 0.039. The comparison of the areas under the ROC curves for the two microbiological tests showed that sonicate fluid was significantly different from peri-implant tissue in delayed (0.951 vs 0.829, p = 0.005) and late PJI (0.901 vs 0.778, p = 0.000). The conjunction of preoperative parameters, synovial fluid culture and CRP, improved the accuracy for late PJI (p = 0.01). The conjunction of histopathology and sonicate fluid culture increased the area under ROC curve of sonication in early (0.917 vs 1.000); p = 0.06 and late cases (0.901 vs 0.999); p < 0.001. For early PJI, sonicate fluid and peri-implant tissue cultures achieve the same best sensitivity. For delayed and late PJI, sonicate fluid culture is the most sensitive individual diagnostic method. By combining histopathology and peri-implant tissue, all early, 97% of delayed and 94.8% of late cases are diagnosed. The conjunction of histopathology and sonicate fluid culture yields a sensitivity of 100% for all types of infection.

  10. Saliva as a Diagnostic Fluid

    PubMed Central

    Malamud, Daniel; Rodriguez-Chavez, Isaac R.

    2010-01-01

    Synopsis Salivary diagnostics is a dynamic and emerging field utilizing nanotechnology and molecular diagnostics to aid in the diagnosis of oral and systemic diseases. Here, we critically review the latest advances using oral biomarkers for disease detection. The use of oral fluids is broadening perspectives in clinical diagnosis, disease monitoring and decision making for patient care. Important elements determining the future possibilities and challenges in this field are also discussed. PMID:21094724

  11. Evaluation of Spontaneous Spinal Cerebrospinal Fluid Leaks Disease by Computerized Image Processing.

    PubMed

    Yıldırım, Mustafa S; Kara, Sadık; Albayram, Mehmet S; Okkesim, Şükrü

    2016-05-17

    Spontaneous Spinal Cerebrospinal Fluid Leaks (SSCFL) is a disease based on tears on the dura mater. Due to widespread symptoms and low frequency of the disease, diagnosis is problematic. Diagnostic lumbar puncture is commonly used for diagnosing SSCFL, though it is invasive and may cause pain, inflammation or new leakages. T2-weighted MR imaging is also used for diagnosis; however, the literature on T2-weighted MRI states that findings for diagnosis of SSCFL could be erroneous when differentiating the diseased and control. One another technique for diagnosis is CT-myelography, but this has been suggested to be less successful than T2-weighted MRI and it needs an initial lumbar puncture. This study aimed to develop an objective, computerized numerical analysis method using noninvasive routine Magnetic Resonance Images that can be used in the evaluation and diagnosis of SSCFL disease. Brain boundaries were automatically detected using methods of mathematical morphology, and a distance transform was employed. According to normalized distances, average densities of certain sites were proportioned and a numerical criterion related to cerebrospinal fluid distribution was calculated. The developed method was able to differentiate between 14 patients and 14 control subjects significantly with p = 0.0088 and d = 0.958. Also, the pre and post-treatment MRI of four patients was obtained and analyzed. The results were differentiated statistically (p = 0.0320, d = 0.853). An original, noninvasive and objective diagnostic test based on computerized image processing has been developed for evaluation of SSCFL. To our knowledge, this is the first computerized image processing method for evaluation of the disease. Discrimination between patients and controls shows the validity of the method. Also, post-treatment changes observed in four patients support this verdict.

  12. Analysis of cellular and protein content of broncho-alveolar lavage fluid from patients with idiopathic pulmonary fibrosis and chronic hypersensitivity pneumonitis.

    PubMed Central

    Reynolds, H Y; Fulmer, J D; Kazmierowski, J A; Roberts, W C; Frank, M M; Crystal, R G

    1977-01-01

    To evaluate cellular and protein components in the lower respiratory tract of patients with idiopathic pulmonary fibrosis (IPF) and chronic hypersensitivity pneumonitis (CHP), limited broncho-alveolar lavage was done in 58 patients (19 IPF, 7 CHP, and 32 controls). Analysis of the cells and protein in the lavage fluids from patients with IPF revealed an inflammatory and eosinophilic response and a significant elevation of IgG in the lungs. With corticosteroid therapy, inflammation diminished but eosinophils remained. Lavage fluid from patients with CHP also had eosinophils and elevated levels of IgG. However, in contrast to IPF, lavage fluid from CHP patients contained IgM, fewer inflammatory cells, and a strikingly increased number (38-74%) of lymphocytes. Identification of lavage lymphocytes in CHP showed that T lymphocytes were significantly elevated and B lymphocytes were decreased compared to peripheral blood. These studies suggest nthat the lung in IPF and CHP may function as a relatively independent immune organ, and that analysis of cells and proteins in broncho-alveolar lavage fluid may be of diagnostic, therapeutic, and investigative value in evaluating patients with fibrotic lung disease. PMID:830661

  13. Assessment of extracellular dehydration using saliva osmolality.

    PubMed

    Ely, Brett R; Cheuvront, Samuel N; Kenefick, Robert W; Spitz, Marissa G; Heavens, Kristen R; Walsh, Neil P; Sawka, Michael N

    2014-01-01

    When substantial solute losses accompany body water an isotonic hypovolemia (extracellular dehydration) results. The potential for using blood or urine to assess extracellular dehydration is generally poor, but saliva is not a simple ultra-filtrate of plasma and the autonomic regulation of salivary gland function suggests the possibility that saliva osmolality (Sosm) may afford detection of extracellular dehydration via the influence of volume-mediated factors. This study aimed to evaluate the assessment of extracellular dehydration using Sosm. In addition, two common saliva collection methods and their effects on Sosm were compared. Blood, urine, and saliva samples were collected in 24 healthy volunteers during paired euhydration and dehydration trials. Furosemide administration and 12 h fluid restriction were used to produce extracellular dehydration. Expectoration and salivette collection methods were compared in a separate group of eight euhydrated volunteers. All comparisons were made using paired t-tests. The diagnostic potential of body fluids was additionally evaluated. Dehydration (3.1 ± 0.5% loss of body mass) decreased PV (-0.49 ± 0.12 L; -15.12 ± 3.94% change), but Sosm changes were marginal (<10 mmol/kg) and weakly correlated with changes in absolute or relative PV losses. Overall diagnostic accuracy was poor (AUC = 0.77-0.78) for all body fluids evaluated. Strong agreement was observed between Sosm methods (Expectoration: 61 ± 10 mmol/kg, Salivette: 61 ± 8 mmol/kg, p > 0.05). Extracelluar dehydration was not detectable using plasma, urine, or saliva measures. Salivette and expectoration sampling methods produced similar, consistent results for Sosm, suggesting no methodological influence on Sosm.

  14. Hall effects on MHD flow of heat generating/absorbing fluid through porous medium in a rotating parallel plate channel

    NASA Astrophysics Data System (ADS)

    Swarnalathamma, B. V.; Krishna, M. Veera

    2017-07-01

    We studied heat transfer on MHD convective flow of viscous electrically conducting heat generating/absorbing fluid through porous medium in a rotating channel under uniform transverse magnetic field normal to the channel and taking Hall current. The flow is governed by the Brinkman's model. The diagnostic solutions for the velocity and temperature are obtained by perturbation technique and computationally discussed with respect to flow parameters through the graphs. The skin friction and Nusselt number are also evaluated and computationally discussed with reference to pertinent parameters in detail.

  15. Diagnostics optiques pour la mesure de fluides critiques en micro-gravité dans les instruments ALICE et DECLIC

    NASA Astrophysics Data System (ADS)

    Durieux, Alain; Babolat, Claude; Dureux, Pierre; Martin, Bernard

    2018-04-01

    This paper, "Diagnostics optiques pour la mesure de fluides critiques en micro-gravité dans les instruments ALICE et DECLIC," was presented as part of International Conference on Space Optics—ICSO 1997, held in Toulouse, France.

  16. Diagnostic value of pleural fluid N-terminal pro-brain natriuretic peptide levels in patients with cardiovascular diseases.

    PubMed

    Liao, Huai; Na, Moon Jun; Dikensoy, Oner; Lane, Kirk B; Randal, Barnette; Light, Richard W

    2008-01-01

    The diagnosis of the cause of pleural effusions caused by cardiovascular diseases such as congestive heart failure (CHF) and acute pulmonary embolism is sometimes difficult. The purpose of the present study was to evaluate the utility of pleural fluid levels of N-terminal pro-brain natriuretic peptide (NT-proBNP) in differentiating pleural effusions due to CHF, pulmonary embolism and post-coronary artery bypass graft (CABG) surgery. The levels of pleural fluid NT-proBNP were measured by ELISA in a total of 40 patients: 10 with CHF, 10 with pulmonary embolism, 10 post-CABG and 10 with carcinoma. The median level of NT-proBNP in the pleural fluid of patients with CHF was 5390 pg/mL (25th to 75th percentiles, 4566 to 8158 pg/mL), which was significantly higher than that in patients with post-CABG effusions (424 pg/mL, 352 to 873), with pulmonary embolism (311 pg/mL, 212 to 1159), or with carcinoma (302 pg/mL, 208 to 626) (P < 0.001, CHF group vs all other groups). In receiver-operating curve analysis, an NT-proBNP level of >or=2220 pg/mL demonstrated a sensitivity of 100% and a specificity of 96.7% for the identification of CHF. Measurement of the NT-proBNP level in pleural fluid is accurate in diagnosing the etiology of the effusion as CHF. Pleural fluid levels above 2220 pg/mL are essentially diagnostic that the pleural effusion is due to CHF.

  17. Does the Alpha-defensin Immunoassay or the Lateral Flow Test Have Better Diagnostic Value for Periprosthetic Joint Infection? A Systematic Review.

    PubMed

    Eriksson, Hannah K; Nordström, Jakob; Gabrysch, Katja; Hailer, Nils P; Lazarinis, Stergios

    2018-05-01

    Measuring alpha-defensin concentrations in synovial fluid may help to diagnose periprosthetic joint infection (PJI). There are two commercially available methods for measuring alpha-defensin in synovial fluid: the enzyme-linked immunosorbent assay-based Synovasure® alpha-defensin immunoassay, which gives a numeric readout within 24 hours, and the Synovasure lateral flow test, which gives a binary readout within 20 minutes. There is no compilation of the existing literature to support the use of one of these two tests over the other. Does the immunoassay or the lateral flow test have better diagnostic value (sensitivity and specificity) in diagnosing PJI? We followed PRISMA guidelines and identified all studies on alpha-defensin concentration in synovial fluid as a PJI diagnostic marker, indexed to April 14, 2017, in PubMed, JSTOR, Google Scholar, and OVID databases. The search retrieved 1578 records. All prospective and retrospective studies on alpha-defensin as a PJI marker (PJI classified according to the criteria of the Musculoskeletal Infection Society) after THA or TKA were included in the analysis. All studies used only one of the two commercially available test methods, but none of them was comparative. After excluding studies with overlapping patient populations, four studies investigating the alpha-defensin immunoassay and three investigating the lateral flow test remained. Alpha-defensin immunoassay studies included 482 joints and lateral flow test studies included 119. The quality of the trials was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. The heterogeneity among studies was evaluated by the I index, indicating that the heterogeneity of the included studies was low. Pooled sensitivity, specificity, positive and negative likelihood ratios, and receiver operating curves were calculated for each method and compared with each other. The alpha-defensin immunoassay had superior overall diagnostic value compared with the lateral flow test (area under the curve, 0.98 versus 0.75) with higher sensitivity (96% [90%-98%] versus 71% [55%-83%], p < 0.001), but no difference in specificity with the numbers available (96% [93%-97%] versus 90% [81%-95%], p = 0.060). Measurement of alpha-defensin in synovial fluid is a valuable complement to existing diagnostic criteria, and the immunoassay test detects PJI more accurately than the lateral flow test. The lateral flow test has lower sensitivity, making it difficult to rule out infection, but its relatively high specificity combined with the advantage of a quick response time can make it useful to rule in infection perioperatively. Level III, diagnostic study.

  18. Human Chorionic Gonadotropine in Cul-de-sac Fluid in Tubal Ectopic Pregnacy; A New Diagnostic Approach

    PubMed Central

    Karahasanoglu, Ayse; Ozdemir, Mucize; Yazicioglu, Fehmi

    2016-01-01

    Introduction Although new diagnostic abilities are being utilised increasingly yet early detection of tubal pregnancy remains a challenge. The use of highly sensitive hCG kits has facilitated the early diagnosis of a pregnancy. But it takes time to determine the localisation of the pregnancy. Early diagnosis of ectopic pregnancy may reduce the morbidity of ectopic pregnancy. Aim This study was conducted to analyse the cul-de-sac and serum βhCG ratio in tubal ectopic pregnancy cases which may be a new diagnostic approach for ectopic pregnancy. Materials and Methods Between January 2004 and July 2011, 263 patients with ectopic pregnancy were included in the study. Risk factors of patients and treatment modalities were evaluated. hCG was measured in peripheral serum and peritoneal fluid, obtained by puncture of Douglas pouch in 52 patients with tubal ectopic pregnancy. hCG level was determined in the cul-de-sac fluid and in the maternal serum for comparison. Results Tubectomy (5.3%), history of abortion (9.5%), history of previous surgery (14.8%), previous cesarean section (8%) and pelvic infamatorry disease (15.9 %) were the important risk factors for ectopic pregnancy in our cases. In 51 of 52 patients with tubal pregnancy, the cul-de-sac hCG vaule and the serum hCG value ratio was >1. Conclusion It is concluded that the ratio of hCG in cul-de –sac and serum can be used for the verification of tubal ectopic pregnancy in addition to other diagnostic methods. This may help rapid confirmation of the diagnosis of ectopic pregnancy. PMID:27190895

  19. Reactive oxygen species modulator 1 (Romo1) as a novel diagnostic marker for lung cancer-related malignant effusion

    PubMed Central

    Lee, Seung Hyeun; Park, Myung Jae; Choi, Sue In; Lee, Eun Joo; Lee, Sang Yeub; In, Kwang Ho

    2017-01-01

    Abstract Reactive oxygen species modulator 1 (Romo1) is a novel protein that plays an important role in intracellular reactive oxygen species generation. Recently, Romo1 has been suggested to have diagnostic and prognostic potential in lung cancer. However, there is no data on the diagnostic value of Romo1 level in malignant pleural effusion. We evaluated the clinical usefulness of Romo1 in pleural fluid for the diagnosis of malignant effusion in lung cancer patients. Pleural fluid Romo1 level was measured using enzyme-linked immunosorbent assay and compared between lung cancer-associated malignant effusion (n = 53; 29 adenocarcinomas and 24 squamous cell carcinomas) and benign pleural effusions (n = 91; 31 tuberculous pleurisy, 30 parapneumonic effusion, and 30 transudate). The discriminative power of Romo1 for lung cancer-associated malignant effusion was determined using receiver operating characteristic (ROC) curve analysis and compared with those of other tumor markers. Median Romo1 level in lung cancer-associated malignant effusion was 99.3 ng/mL, which was significantly higher than that in benign pleural effusions (P < 0.001). The optimal cutoff value of Romo1 to discriminate lung cancer-associated malignant effusion from benign effusions was 67.0 ng/mL with a sensitivity of 73.8% and a specificity of 84.1%. The area under the curve was 0.837 (95% confidence interval [CI]: 0.750–0.886), which was significantly better than that of cytokeratin 19 fragments (P < 0.001). Pleural fluid Romo1 could discriminate lung cancer from benign diseases with considerable sensitivity and specificity. Our findings suggest a diagnostic potential of Romo1 for lung cancer-associated malignant effusion. PMID:28121949

  20. Amylase in drain fluid for the diagnosis of pancreatic leak in post-pancreatic resection.

    PubMed

    Davidson, Tsetsegdemberel Bat-Ulzii; Yaghoobi, Mohammad; Davidson, Brian R; Gurusamy, Kurinchi Selvan

    2017-04-07

    The treatment of people with clinically significant postoperative pancreatic leaks is different from those without clinically significant pancreatic leaks. It is important to know the diagnostic accuracy of drain fluid amylase as a triage test for the detection of clinically significant pancreatic leaks, so that an informed decision can be made as to whether the patient with a suspected pancreatic leak needs further investigations and treatment. There is currently no systematic review of the diagnostic test accuracy of drain fluid amylase for the diagnosis of clinically relevant pancreatic leak. To determine the diagnostic accuracy of amylase in drain fluid at 48 hours or more for the diagnosis of pancreatic leak in people who had undergone pancreatic resection. We searched MEDLINE, Embase, the Science Citation Index Expanded, and the National Institute for Health Research Health Technology Assessment (NIHR HTA) websites up to 20 February 2017. We searched the references of the included studies to identify additional studies. We did not restrict studies based on language or publication status, or whether data were collected prospectively or retrospectively. We also performed a 'related search' and 'citing reference' search in MEDLINE and Embase. We included all studies that evaluated the diagnostic test accuracy of amylase in the drain fluid at 48 hours or more for the diagnosis of pancreatic leak in people who had undergone pancreatic resection excluding total pancreatectomy. We planned to exclude case-control studies because these studies are prone to bias, but did not find any. At least two authors independently searched and screened the references produced by the search to identify relevant studies. Two review authors independently extracted data from the included studies. The included studies reported drain fluid amylase on different postoperative days and measured at different cut-off levels, so it was not possible to perform a meta-analysis using the bivariate model as planned. We have reported the sensitivity, specificity, post-test probability of a positive and negative drain fluid amylase along with 95% confidence interval (CI) on each of the different postoperative days and measured at different cut-off levels. A total of five studies including 868 participants met the inclusion criteria for this review. The five studies included in this review reported the value of drain fluid amylase at different thresholds and different postoperative days. The sensitivities and specificities were variable; the sensitivities ranged between 0.72 and 1.00 while the specificities ranged between 0.73 and 0.99 for different thresholds on different postoperative days. At the median prevalence (pre-test probability) of 15.9%, the post-test probabilities for pancreatic leak ranged between 35.9% and 95.4% for a positive drain fluid amylase test and ranged between 0% and 5.5% for a negative drain fluid amylase test.None of the studies used the reference standard of confirmation by surgery or by a combination of surgery and clinical follow-up, but used the International Study Group on Pancreatic Fistula (ISGPF) grade B and C as the reference standard. The overall methodological quality was unclear or high in all the studies. Because of the paucity of data and methodological deficiencies in the studies, we are uncertain whether drain fluid amylase should be used as a method for testing for pancreatic leak in an unselected population after pancreatic resection; and we judge that the optimal cut-off of drain fluid amylase for making the diagnosis of pancreatic leak is also not clear. Further well-designed diagnostic test accuracy studies with pre-specified index test threshold of drain fluid amylase (at three times more on postoperative day 5 or another suitable pre-specified threshold), appropriate follow-up (for at least six to eight weeks to ensure that there are no pancreatic leaks), and clearly defined reference standards (of surgical, clinical, and radiological confirmation of pancreatic leak) are important to reliably determine the diagnostic accuracy of drain fluid amylase in the diagnosis of pancreatic leak.

  1. Workshop on Laser Diagnostics in Fluid Mechanics and Combustion Held in Fishermens Bend, Victoria on 30 September-1 October 1993

    DTIC Science & Technology

    1993-10-01

    S...... ~ t i . .. . . . . . . FOREWORD The development of laser- based methods for observation and measurement of fluid dynamic phenomena has...Hypersonic Flows ......................... 18 P.C. Palma, A.F.P. Houwing and R.J. Sandeman Timing Problems in Laser Based Combustion Diagnostics...A.F.P. Houwing and R.J. Sandeman Laser- Based Methods for Hypervelocity Flow and Combustion Diagnostics ...... 21 H. Rubinsztein-Dunlop, P. Barker, A

  2. Extent of agreement between the body fluid model of Sysmex XN-20 and the manual microscopy method.

    PubMed

    Huang, Wei-Hua; Lu, Lin-Peng; Wu, Kang; Guo, Fang-Yu; Guo, Jie; Yu, Jing-Long; Zhou, Dao-Yin; Sun, Yi; Deng, An-Mei

    2017-09-01

    Although the correlations concerning cellular component analysis between the Sysmex XN-20 body fluid (BF) model and manual microscopy have been investigated by several studies, the extent of agreement between these two methods has not been investigated. A total of 90 BF samples were prospectively collected and analyzed using the Sysmex XN-20 BF model and microscopy. The extent of agreement between these two methods was evaluated using the Bland-Altman approach. Receiver operating characteristic (ROC) curve analysis was employed to evaluate the diagnostic accuracy of high-fluorescence (HF) BF cells for malignant diseases. The agreements of white blood cell (WBC), red blood cell (RBC), and percentages of neutrophils, lymphocytes, and monocytes between the Sysmex XN-20 BF model and manual microscopy were imperfect. The areas under the ROC curves for absolute and relative HF cells were 0.67 (95% confidence interval [CI]: 0.56-0.78) and 0.60 (95% CI: 0.48-0.72), respectively. Due to the Sysmex XN-20 BF model's imperfect agreement with manual microscopy and its weak diagnostic accuracy for malignant diseases, the current evidence does not support replacing manual microscopy with this model in clinical practice. © 2016 Wiley Periodicals, Inc.

  3. FDNS CFD Code Benchmark for RBCC Ejector Mode Operation

    NASA Technical Reports Server (NTRS)

    Holt, James B.; Ruf, Joe

    1999-01-01

    Computational Fluid Dynamics (CFD) analysis results are compared with benchmark quality test data from the Propulsion Engineering Research Center's (PERC) Rocket Based Combined Cycle (RBCC) experiments to verify fluid dynamic code and application procedures. RBCC engine flowpath development will rely on CFD applications to capture the multi-dimensional fluid dynamic interactions and to quantify their effect on the RBCC system performance. Therefore, the accuracy of these CFD codes must be determined through detailed comparisons with test data. The PERC experiments build upon the well-known 1968 rocket-ejector experiments of Odegaard and Stroup by employing advanced optical and laser based diagnostics to evaluate mixing and secondary combustion. The Finite Difference Navier Stokes (FDNS) code was used to model the fluid dynamics of the PERC RBCC ejector mode configuration. Analyses were performed for both Diffusion and Afterburning (DAB) and Simultaneous Mixing and Combustion (SMC) test conditions. Results from both the 2D and the 3D models are presented.

  4. Non-Newtonian fluid structure interaction in flexible biomimetic microchannels

    NASA Astrophysics Data System (ADS)

    Kiran, M.; Dasgupta, Sunando; Chakraborty, Suman

    2017-11-01

    To investigate the complex fluid structure interactions in a physiologically relevant microchannel with deformable wall and non-Newtonian fluid that flows within it, we fabricated cylindrical microchannels of various softness out of PDMS. Experiments to measure the transient pressure drop across the channel were carried out with high sampling frequencies to capture the intricate flow physics. In particular, we showed that the waveforms varies greatly for each of the non-Newtonian and Newtonian cases for both non-deformable and deformable microchannels in terms of the peak amplitude, r.m.s amplitude and the crest factor. In addition, we carried out frequency sweep experiments to evaluate the frequency response of the system. We believe that these results will aid in the design of polymer based microfluidic phantoms for arterial FSI studies, and in particular for studying blood analog fluids in cylindrical microchannels as well as developing frequency specific Lab-on-chip systems for medical diagnostics.

  5. Secondary Signs May Improve the Diagnostic Accuracy of Equivocal Ultrasounds for Suspected Appendicitis in Children

    PubMed Central

    Partain, Kristin N.; Patel, Adarsh; Travers, Curtis; McCracken, Courtney; Loewen, Jonathan; Braithwaite, Kiery; Heiss, Kurt F.; Raval, Mehul V.

    2016-01-01

    Introduction Ultrasound (US) is the preferred imaging modality for evaluating appendicitis. Our purpose was to determine if including secondary signs (SS) improves diagnostic accuracy in equivocal US studies. Methods Retrospective review identified 825 children presenting with concern for appendicitis and with a right lower quadrant (RLQ) US. Regression models identified which SS were associated with appendicitis. Test characteristics were demonstrated. Results 530 patients (64%) had equivocal US reports. Of 114 (22%) patients with equivocal US undergoing CT, those with SS were more likely to have appendicitis (48.6% vs 14.6%, p<0.001). Of 172 (32%) patients with equivocal US admitted for observation, those with SS were more likely to have appendicitis (61.0% vs 33.6%, p<0.001). SS associated with appendicitis included fluid collection (adjusted odds ratio (OR) 13.3, 95% Confidence Interval (CI) 2.1–82.8), hyperemia (OR=2.0, 95%CI 1.5–95.5), free fluid (OR=9.8, 95%CI 3.8–25.4), and appendicolith (OR=7.9, 95%CI 1.7–37.2). Wall thickness, bowel peristalsis, and echogenic fat were not associated with appendicitis. Equivocal US that included hyperemia, a fluid collection, or an appendicolith had 96% specificity and 88% accuracy. Conclusion Use of SS in RLQ US assists in the diagnostic accuracy of appendicitis. SS may guide clinicians and reduce unnecessary CT and admissions. PMID:27039121

  6. Cerebrospinal fluid and blood biomarkers for neurodegenerative dementias: An update of the Consensus of the Task Force on Biological Markers in Psychiatry of the World Federation of Societies of Biological Psychiatry.

    PubMed

    Lewczuk, Piotr; Riederer, Peter; O'Bryant, Sid E; Verbeek, Marcel M; Dubois, Bruno; Visser, Pieter Jelle; Jellinger, Kurt A; Engelborghs, Sebastiaan; Ramirez, Alfredo; Parnetti, Lucilla; Jack, Clifford R; Teunissen, Charlotte E; Hampel, Harald; Lleó, Alberto; Jessen, Frank; Glodzik, Lidia; de Leon, Mony J; Fagan, Anne M; Molinuevo, José Luis; Jansen, Willemijn J; Winblad, Bengt; Shaw, Leslie M; Andreasson, Ulf; Otto, Markus; Mollenhauer, Brit; Wiltfang, Jens; Turner, Martin R; Zerr, Inga; Handels, Ron; Thompson, Alexander G; Johansson, Gunilla; Ermann, Natalia; Trojanowski, John Q; Karaca, Ilker; Wagner, Holger; Oeckl, Patrick; van Waalwijk van Doorn, Linda; Bjerke, Maria; Kapogiannis, Dimitrios; Kuiperij, H Bea; Farotti, Lucia; Li, Yi; Gordon, Brian A; Epelbaum, Stéphane; Vos, Stephanie J B; Klijn, Catharina J M; Van Nostrand, William E; Minguillon, Carolina; Schmitz, Matthias; Gallo, Carla; Lopez Mato, Andrea; Thibaut, Florence; Lista, Simone; Alcolea, Daniel; Zetterberg, Henrik; Blennow, Kaj; Kornhuber, Johannes

    2018-06-01

    In the 12 years since the publication of the first Consensus Paper of the WFSBP on biomarkers of neurodegenerative dementias, enormous advancement has taken place in the field, and the Task Force takes now the opportunity to extend and update the original paper. New concepts of Alzheimer's disease (AD) and the conceptual interactions between AD and dementia due to AD were developed, resulting in two sets for diagnostic/research criteria. Procedures for pre-analytical sample handling, biobanking, analyses and post-analytical interpretation of the results were intensively studied and optimised. A global quality control project was introduced to evaluate and monitor the inter-centre variability in measurements with the goal of harmonisation of results. Contexts of use and how to approach candidate biomarkers in biological specimens other than cerebrospinal fluid (CSF), e.g. blood, were precisely defined. Important development was achieved in neuroimaging techniques, including studies comparing amyloid-β positron emission tomography results to fluid-based modalities. Similarly, development in research laboratory technologies, such as ultra-sensitive methods, raises our hopes to further improve analytical and diagnostic accuracy of classic and novel candidate biomarkers. Synergistically, advancement in clinical trials of anti-dementia therapies energises and motivates the efforts to find and optimise the most reliable early diagnostic modalities. Finally, the first studies were published addressing the potential of cost-effectiveness of the biomarkers-based diagnosis of neurodegenerative disorders.

  7. A New Mixing Diagnostic and Gulf Oil Spill Movement

    NASA Astrophysics Data System (ADS)

    Mezić, Igor; Loire, S.; Fonoberov, Vladimir A.; Hogan, P.

    2010-10-01

    Chaotic advection has served as the paradigm for mixing in fluid flows with simple time dependence. Its skeletal structure is based on analysis of invariant attracting and repelling manifolds in fluid flows. Here we develop a finite-time theory for two-dimensional incompressible fluid flows with arbitrary time dependence and introduce a new mixing diagnostic based on it. Besides stretching events around attracting and repelling manifolds, this allows us to detect hyperbolic mixing zones. We used the new diagnostic to forecast the spatial location and timing of oil washing ashore in Plaquemines Parish and Grand Isle, Louisiana, and Pensacola, Florida, in May 2010 and the flow of oil toward Panama City Beach, Florida, in June 2010.

  8. Biochemical and Cytological Comparison of Keratocystic Odontogenic Tumours to Nonkeratinising Odontogenic Cysts Fluid.

    PubMed

    Patidar, Madhvika; Shetty, Pushparaj; Patidar, Nitesh; Mittal, Sugandh; Singh, Hanspal; Chethna

    2015-07-01

    To evaluate the levels of albumin, prealbumin, total protein, inorganic phosphate and presence of keratinocytes in the cystic fluid for the diagnosis and appropriate treatment planning of keratocystic odontogenic tumours and other non keratinizing odontogenic cysts. Fifteen keratocystic odontogenic tumour and 15 controls were studied. The cystic fluid was aspirated and analysed to determine the levels of albumin, prealbumin, total protein, inorganic phosphate and the presence of keratinocytes. The data collected was statistically evaluated using Mann Whitney U-Test and Student's t-test. A highly significant difference (p<0.0001) was seen when a comparison of Prealbumin, total protein, inorganic phosphate and presence of keratinocytes was made between keratocystic odontogenic tumour and non keratinizing odontogenic cysts. The presence of albumin also showed a significant difference (p<0.01). A combined analysis of total protein, albumin, prealbumin, inorganic phosphorous and detection of epithelial squames may be used as a diagnostic adjunct in the preoperative diagnosis of keratocystic odontogenic tumour in a minimally invasive and highly accurate fashion.

  9. A differentially expressed set of microRNAs in cerebro-spinal fluid (CSF) can diagnose CNS malignancies

    PubMed Central

    Drusco, Alessandra; Bottoni, Arianna; Laganà, Alessandro; Acunzo, Mario; Fassan, Matteo; Cascione, Luciano; Antenucci, Anna; Kumchala, Prasanthi; Vicentini, Caterina; Gardiman, Marina P.; Alder, Hansjuerg; Carosi, Mariantonia A.; Ammirati, Mario; Gherardi, Stefano; Luscrì, Marilena; Carapella, Carmine; Zanesi, Nicola; Croce, Carlo M.

    2015-01-01

    Central Nervous System malignancies often require stereotactic biopsy or biopsy for differential diagnosis, and for tumor staging and grading. Furthermore, stereotactic biopsy can be non-diagnostic or underestimate grading. Hence, there is a compelling need of new diagnostic biomarkers to avoid such invasive procedures. Several biological markers have been proposed, but they can only identify specific prognostic subtype of Central Nervous System tumors, and none of them has found a standardized clinical application. The aim of the study was to identify a Cerebro-Spinal Fluid microRNA signature that could differentiate among Central Nervous System malignancies. CSF total RNA of 34 neoplastic and of 14 non-diseased patients was processed by NanoString. Comparison among groups (Normal, Benign, Glioblastoma, Medulloblastoma, Metastasis and Lymphoma) lead to the identification of a microRNA profile that was further confirmed by RT-PCR and in situ hybridization. Hsa-miR-451, -711, 935, -223 and -125b were significantly differentially expressed among the above mentioned groups, allowing us to draw an hypothetical diagnostic chart for Central Nervous System malignancies. This is the first study to employ the NanoString technique for Cerebro-Spinal Fluid microRNA profiling. In this article, we demonstrated that Cerebro-Spinal Fluid microRNA profiling mirrors Central Nervous System physiologic or pathologic conditions. Although more cases need to be tested, we identified a diagnostic Cerebro-Spinal Fluid microRNA signature with good perspectives for future diagnostic clinical applications. PMID:26246487

  10. A differentially expressed set of microRNAs in cerebro-spinal fluid (CSF) can diagnose CNS malignancies.

    PubMed

    Drusco, Alessandra; Bottoni, Arianna; Laganà, Alessandro; Acunzo, Mario; Fassan, Matteo; Cascione, Luciano; Antenucci, Anna; Kumchala, Prasanthi; Vicentini, Caterina; Gardiman, Marina P; Alder, Hansjuerg; Carosi, Mariantonia A; Ammirati, Mario; Gherardi, Stefano; Luscrì, Marilena; Carapella, Carmine; Zanesi, Nicola; Croce, Carlo M

    2015-08-28

    Central Nervous System malignancies often require stereotactic biopsy or biopsy for differential diagnosis, and for tumor staging and grading. Furthermore, stereotactic biopsy can be non-diagnostic or underestimate grading. Hence, there is a compelling need of new diagnostic biomarkers to avoid such invasive procedures. Several biological markers have been proposed, but they can only identify specific prognostic subtype of Central Nervous System tumors, and none of them has found a standardized clinical application.The aim of the study was to identify a Cerebro-Spinal Fluid microRNA signature that could differentiate among Central Nervous System malignancies.CSF total RNA of 34 neoplastic and of 14 non-diseased patients was processed by NanoString. Comparison among groups (Normal, Benign, Glioblastoma, Medulloblastoma, Metastasis and Lymphoma) lead to the identification of a microRNA profile that was further confirmed by RT-PCR and in situ hybridization.Hsa-miR-451, -711, 935, -223 and -125b were significantly differentially expressed among the above mentioned groups, allowing us to draw an hypothetical diagnostic chart for Central Nervous System malignancies.This is the first study to employ the NanoString technique for Cerebro-Spinal Fluid microRNA profiling. In this article, we demonstrated that Cerebro-Spinal Fluid microRNA profiling mirrors Central Nervous System physiologic or pathologic conditions. Although more cases need to be tested, we identified a diagnostic Cerebro-Spinal Fluid microRNA signature with good perspectives for future diagnostic clinical applications.

  11. Acoustic radiation force impulse (ARFI) ultrasound imaging of pancreatic cystic lesions.

    PubMed

    D'Onofrio, M; Gallotti, A; Salvia, R; Capelli, P; Mucelli, R Pozzi

    2011-11-01

    To evaluate the ARFI ultrasound imaging with Virtual Touch tissue quantification in studying pancreatic cystic lesions, compared with phantom fluid models. Different phantom fluids at different viscosity or density (water, iodinate contrast agent, and oil) were evaluated by two independent operators. From September to December 2008, 23 pancreatic cystic lesions were prospectively studied. All lesions were pathologically confirmed. Non-numerical values on water and numerical values on other phantoms were obtained. Inter-observer evaluation revealed a perfect correlation (rs=1.00; p<0.0001) between all measurements achieved by both operators per each balloon and fluid. Among the pancreatic cystic lesions, 14 mucinous cystadenomas, 4 pseudocysts, 3 intraductal papillary-mucinous neoplasms and 2 serous cystadenomas were studied. The values obtained ranged from XXXX/0-4,85 m/s in mucinous cystadenomas, from XXXX/0-3,11 m/s in pseudocysts, from XXXX/0-4,57 m/s in intraductal papillary-mucinous neoplasms. In serous cystadenomas all values measured were XXXX/0m/s. Diagnostic accuracy in benign and non-benign differentiation of pancreatic cystic lesions was 78%. Virtual Touch tissue quantification can be applied in the analysis of fluids and is potentially able to differentiate more complex (mucinous) from simple (serous) content in studying pancreatic cystic lesions. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  12. Differentiation between Cystic Pituitary Adenomas and Rathke Cleft Cysts: A Diagnostic Model Using MRI.

    PubMed

    Park, M; Lee, S-K; Choi, J; Kim, S-H; Kim, S H; Shin, N-Y; Kim, J; Ahn, S S

    2015-10-01

    Cystic pituitary adenomas may mimic Rathke cleft cysts when there is no solid enhancing component found on MR imaging, and preoperative differentiation may enable a more appropriate selection of treatment strategies. We investigated the diagnostic potential of MR imaging features to differentiate cystic pituitary adenomas from Rathke cleft cysts and to develop a diagnostic model. This retrospective study included 54 patients with a cystic pituitary adenoma (40 women; mean age, 37.7 years) and 28 with a Rathke cleft cyst (18 women; mean age, 31.5 years) who underwent MR imaging followed by surgery. The following imaging features were assessed: the presence or absence of a fluid-fluid level, a hypointense rim on T2-weighted images, septation, an off-midline location, the presence or absence of an intracystic nodule, size change, and signal change. On the basis of the results of logistic regression analysis, a diagnostic tree model was developed to differentiate between cystic pituitary adenomas and Rathke cleft cysts. External validation was performed for an additional 16 patients with a cystic pituitary adenoma and 8 patients with a Rathke cleft cyst. The presence of a fluid-fluid level, a hypointense rim on T2-weighted images, septation, and an off-midline location were more common with pituitary adenomas, whereas the presence of an intracystic nodule was more common with Rathke cleft cysts. Multiple logistic regression analysis showed that cystic pituitary adenomas and Rathke cleft cysts can be distinguished on the basis of the presence of a fluid-fluid level, septation, an off-midline location, and the presence of an intracystic nodule (P = .006, .032, .001, and .023, respectively). Among 24 patients in the external validation population, 22 were classified correctly on the basis of the diagnostic tree model used in this study. A systematic approach using this diagnostic tree model can be helpful in distinguishing cystic pituitary adenomas from Rathke cleft cysts. © 2015 by American Journal of Neuroradiology.

  13. To fine needle aspiration or not? An endosonographer's approach to pancreatic cystic lesions

    PubMed Central

    But, David Yiu-Kuen; Poley, Jan-Werner

    2014-01-01

    Endoscopic ultrasound (EUS) guided fine needle aspiration (FNA) is an established diagnostic tool in the management of pancreatic cystic lesions (PCLs). Due to the proximity to the target lesion, the fine diagnostic needle travels through only minimal normal tissues. The risks of bleeding, pancreatitis and infection are small. Valuable diagnostic morphological information can be obtained by EUS before the use of FNA. The additional cytopathologic and cyst fluid analysis for the conventional markers such as amylase, carcinoembryonic antigen (CEA) and CA19.9 improves the diagnostic capability. Pancreatic cyst fluid CEA concentration of 192 ng/mL is generally the most agreed cutoff to differentiate mucinous from non-mucinous lesion. A fluid amylase level of <250 IU/L excludes the diagnosis of pseudocyst. Technical tips of EUS-FNA and the limitations of the procedure are discussed. Promising technique and FNA needle modifications have been described to improve the diagnostic yield at the cytopathologic analysis. The use of novel cyst fluid proteomics and deoxyribonucleic acid-based biomarkers of the PCLs are reviewed. Although it is considered a safe procedure, EUS-FNA is not a routine in every patient. Recommendations of the role of EUS-FNA at various common clinical scenarios are discussed. PMID:24955337

  14. Body fluid matrix evaluation on a Roche cobas 8000 system.

    PubMed

    Owen, William E; Thatcher, Mindy L; Crabtree, Karolyn J; Greer, Ryan W; Strathmann, Frederick G; Straseski, Joely A; Genzen, Jonathan R

    2015-09-01

    Chemical analysis of body fluids is commonly requested by physicians. Because most commercial FDA-cleared clinical laboratory assays are not validated by diagnostic manufacturers for "non-serum" and "non-plasma" specimens, laboratories may need to complete additional validation studies to comply with regulatory requirements regarding body fluid testing. The objective of this report is to perform recovery studies to evaluate potential body fluid matrix interferences for commonly requested chemistry analytes. Using an IRB-approved protocol, previously collected clinical body fluid specimens (biliary/hepatic, cerebrospinal, dialysate, drain, pancreatic, pericardial, peritoneal, pleural, synovial, and vitreous) were de-identified and frozen (-20°C) until experiments were performed. Recovery studies (spiking with high concentration serum, control, and/or calibrator) were conducted using 10% spiking solution by volume; n=5 specimens per analyte/body fluid investigated. Specimens were tested on a Roche cobas 8000 system (c502, c702, e602, and ISE modules). In all 80 analyte/body fluid combinations investigated (including amylase, total bilirubin, urea nitrogen, carbohydrate antigen 19-9, carcinoembryonic antigen, cholesterol, chloride, creatinine, glucose, potassium, lactate dehydrogenase, lipase, rheumatoid factor, sodium, total protein, triglycerides, and uric acid), the average percent recovery was within predefined acceptable limits (less than ±10% from the calculated ideal recovery). The present study provides evidence against the presence of any systematic matrix interference in the analyte/body fluid combinations investigated on the Roche cobas 8000 system. Such findings support the utility of ongoing body fluid validation initiatives conducted to maintain compliance with regulatory requirements. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  15. Performance characteristics of magnetic resonance imaging without contrast agents or sedation in pediatric appendicitis.

    PubMed

    Didier, Ryne A; Hopkins, Katharine L; Coakley, Fergus V; Krishnaswami, Sanjay; Spiro, David M; Foster, Bryan R

    2017-09-01

    Magnetic resonance imaging (MRI) has emerged as a promising modality for evaluating pediatric appendicitis. However optimal imaging protocols, including roles of contrast agents and sedation, have not been established and diagnostic criteria have not been fully evaluated. To investigate performance characteristics of rapid MRI without contrast agents or sedation in the diagnosis of pediatric appendicitis. We included patients ages 4-18 years with suspicion of appendicitis who underwent rapid MRI between October 2013 and March 2015 without contrast agent or sedation. After two-radiologist review, we determined performance characteristics of individual diagnostic criteria and aggregate diagnostic criteria by comparing MRI results to clinical outcomes. We used receiver operating characteristic (ROC) curves to determine cut-points for appendiceal diameter and wall thickness for optimization of predictive power, and we calculated area under the curve (AUC) as a measure of test accuracy. Ninety-eight MRI examinations were performed in 97 subjects. Overall, MRI had a 94% sensitivity, 95% specificity, 91% positive predictive value and 97% negative predictive value. Optimal cut-points for appendiceal diameter and wall thickness were ≥7 mm and ≥2 mm, respectively. Independently, those cut-points produced sensitivities of 91% and 84% and specificities of 84% and 43%. Presence of intraluminal fluid (30/33) or localized periappendiceal fluid (32/33) showed a significant association with acute appendicitis (P<0.01), with sensitivities of 91% and 97% and specificities of 60% and 50%. For examinations in which the appendix was not identified by one or both reviewers (23/98), the clinical outcome was negative. Rapid MRI without contrast agents or sedation is accurate for diagnosis of pediatric appendicitis when multiple diagnostic criteria are considered in aggregate. Individual diagnostic criteria including optimized cut-points of ≥7 mm for diameter and ≥2 mm for wall thickness demonstrate high sensitivities but relatively low specificities. Nonvisualization of the appendix favors a negative diagnosis.

  16. Effect of saliva stabilisers on detection of porcine reproductive and respiratory syndrome virus in oral fluid by quantitative reverse transcriptase real-time PCR.

    PubMed

    Decorte, Inge; Van der Stede, Yves; Nauwynck, Hans; De Regge, Nick; Cay, Ann Brigitte

    2013-08-01

    This study evaluated the effect of extraction-amplification methods, storage temperature and saliva stabilisers on detection of porcine reproductive and respiratory syndrome virus (PRRSV) RNA by quantitative reverse transcriptase real-time PCR (qRT-PCR) in porcine oral fluid. The diagnostic performance of different extraction-amplification methods was examined using a dilution series of oral fluid spiked with PRRSV. To determine RNA stability, porcine oral fluid, with or without commercially available saliva stabilisers, was spiked with PRRSV, stored at 4°C or room temperature and tested for the presence of PRRSV RNA by qRT-PCR. PRRSV RNA could be detected in oral fluid using all extraction-amplification combinations, but the limit of detection varied amongst different combinations. Storage temperature and saliva stabilisers had an effect on the stability of PRRSV RNA, which could only be detected for 7 days when PRRSV spiked oral fluid was kept at 4°C or stabilised at room temperature with a commercial mRNA stabiliser. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. Value of PCR in sonication fluid for the diagnosis of orthopedic hardware-associated infections: Has the molecular era arrived?

    PubMed

    Renz, Nora; Cabric, Sabrina; Morgenstern, Christian; Schuetz, Michael A; Trampuz, Andrej

    2018-04-01

    Bone healing disturbance following fracture fixation represents a continuing challenge. We evaluated a novel fully automated polymerase chain reaction (PCR) assay using sonication fluid from retrieved orthopedic hardware to diagnose infection. In this prospective diagnostic cohort study, explanted orthopedic hardware materials from consecutive patients were investigated by sonication and the resulting sonication fluid was analyzed by culture (standard procedure) and multiplex PCR (investigational procedure). Hardware-associated infection was defined as visible purulence, presence of a sinus tract, implant on view, inflammation in peri-implant tissue or positive culture. McNemar's chi-squared test was used to compare the performance of diagnostic tests. For the clinical performance all pathogens were considered, whereas for analytical performance only microorganisms were considered for which primers are included in the PCR assay. Among 51 patients, hardware-associated infection was diagnosed in 38 cases (75%) and non-infectious causes in 13 patients (25%). The sensitivity for diagnosing infection was 66% for peri-implant tissue culture, 84% for sonication fluid culture, 71% (clinical performance) and 77% (analytical performance) for sonication fluid PCR, the specificity of all tests was >90%. The analytical sensitivity of PCR was higher for gram-negative bacilli (100%), coagulase-negative staphylococci (89%) and Staphylococcus aureus (75%) than for Cutibacterium (formerly Propionibacterium) acnes (57%), enterococci (50%) and Candida spp. (25%). The performance of sonication fluid PCR for diagnosis of orthopedic hardware-associated infection was comparable to culture tests. The additional advantage of PCR was short processing time (<5 h) and fully automated procedure. With further improvement of the performance, PCR has the potential to complement conventional cultures. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. Cerebrospinal fluid ferritin and albumin index: potential candidates for scoring system to differentiate between bacterial and viral meningitis in children.

    PubMed

    Jebamalar, Angelin A; Prabhat; Balakrishnapillai, Agiesh K; Parmeswaran, Narayanan; Dhiman, Pooja; Rajendiran, Soundravally

    2016-07-01

    To evaluate the diagnostic role of cerebrospinal fluid (CSF) ferritin and albumin index (AI = CSF albumin/serum albumin × 1000) in differentiating acute bacterial meningitis (ABM) from acute viral meningitis (AVM) in children. The study included 42 cases each of ABM and AVM in pediatric age group. Receiver operating characteristic (ROC) analysis was carried out for CSF ferritin and AI. Binary logistic regression was also done. CSF ferritin and AI were found significantly higher in ABM compared to AVM. Model obtained using AI and CSF ferritin along with conventional criteria is better than existing models.

  19. [Parapneumonic pleural effusion: difficulties in making therapeutic decisions].

    PubMed

    Chudzicka, Aleksandra; Chciałowski, Andrzej

    2007-01-01

    Pneumonia is the second most common cause of pleural effusion. The presence of pleural fluid makes the prognosis in patients with pneumonia worse and causes a higher mortality rate. This is why it is very important to undertake suitable treatment as soon as possible. Most parapneumonic pleural effusions resolve with antibiotic alone, but sometimes more invasive treatment is necessary. Therapeutic decisions are based on different criteria. For many years determining biochemical fluid characteristics has been used for this purpose. Presentlythe usefullness of new parameters is being evaluated. Their application in diagnostics was possible thanks to better knowledge of mechanisms that participate in the development of parapneumonic pleural effusion.

  20. Evaluation of different fluids for detection of Clostridium perfringens type D epsilon toxin in sheep with experimental enterotoxemia.

    PubMed

    Layana, Jorge E; Fernandez Miyakawa, Mariano E; Uzal, Francisco A

    2006-08-01

    Enterotoxemia caused by Clostridium perfringens type D is a highly lethal disease of sheep, goats and other ruminants. The diagnosis of this condition is usually confirmed by detection of epsilon toxin, a major exotoxin produced by C. perfringens types B and D, in the intestinal content of affected animals. It has been suggested that other body fluids can also be used for detection of epsilon toxin. This study was performed to evaluate the usefulness of intestinal content versus other body fluids in detecting epsilon toxin in cases of sheep enterotoxemia. Samples of duodenal, ileal and colon contents, pericardial and abdominal fluids, aqueous humor and urine from 15 sheep with experimentally induced enterotoxemia, were analysed for epsilon toxin using a capture ELISA. Epsilon toxin was detected in 92% of the samples of ileal content, 64% of the samples of duodenal content, 57% of the samples of colon content and in 7% of the samples of pericardial fluid and aqueous humor. No epsilon toxin was found in samples of abdominal fluid or urine from the animals with enterotoxemia or in any samples from six clinically healthy sheep used as negative controls. The results of this study indicate that with the diagnostic capture ELISA used, intestinal content (preferably ileum) should be used for C. perfringens type D epsilon toxin detection in suspected cases of sheep enterotoxemia.

  1. Approach to the critically ill camelid.

    PubMed

    Bedenice, Daniela

    2009-07-01

    The estimation of fluid deficits in camelids is challenging. However, early recognition and treatment of shock and hypovolemia is instrumental to improve morbidity and mortality of critically ill camelids. Early goal-directed fluid therapy requires specific knowledge of clinical indicators of hypovolemia and assessment of resuscitation endpoints, but may significantly enhance the understanding, monitoring, and safety of intravenous fluid therapy in South American camelids (SAC). It is important to recognize that over-aggressive fluid resuscitation is just as detrimental as under resuscitation. Nonetheless, a protocol of conservative fluid management is often indicated in the treatment of camelids with pulmonary inflammation, to counteract edema formation. The early recognition of lung dysfunction is often based on advanced diagnostic techniques, including arterial blood gas analysis, diagnostic imaging, and noninvasive pulmonary function testing.

  2. Diagnostic and prognostic value of human prion detection in cerebrospinal fluid.

    PubMed

    Foutz, Aaron; Appleby, Brian S; Hamlin, Clive; Liu, Xiaoqin; Yang, Sheng; Cohen, Yvonne; Chen, Wei; Blevins, Janis; Fausett, Cameron; Wang, Han; Gambetti, Pierluigi; Zhang, Shulin; Hughson, Andrew; Tatsuoka, Curtis; Schonberger, Lawrence B; Cohen, Mark L; Caughey, Byron; Safar, Jiri G

    2017-01-01

    Several prion amplification systems have been proposed for detection of prions in cerebrospinal fluid (CSF), most recently, the measurements of prion seeding activity with second-generation real-time quaking-induced conversion (RT-QuIC). The objective of this study was to investigate the diagnostic performance of the RT-QuIC prion test in the broad phenotypic spectrum of prion diseases. We performed CSF RT-QuIC testing in 2,141 patients who had rapidly progressive neurological disorders, determined diagnostic sensitivity and specificity in 272 cases that were autopsied, and evaluated the impact of mutations and polymorphisms in the PRNP gene, and type 1 or type 2 human prions on diagnostic performance. The 98.5% diagnostic specificity and 92% sensitivity of CSF RT-QuIC in a blinded retrospective analysis matched the 100% specificity and 95% sensitivity of a blind prospective study. The CSF RT-QuIC differentiated 94% of cases of sporadic Creutzfeldt-Jakob disease (sCJD) MM1 from the sCJD MM2 phenotype, and 80% of sCJD VV2 from sCJD VV1. The mixed prion type 1-2 and cases heterozygous for codon 129 generated intermediate CSF RT-QuIC patterns, whereas genetic prion diseases revealed distinct profiles for each PRNP gene mutation. The diagnostic performance of the improved CSF RT-QuIC is superior to surrogate marker tests for prion diseases such as 14-3-3 and tau proteins, and together with PRNP gene sequencing the test allows the major prion subtypes to be differentiated in vivo. This differentiation facilitates prediction of the clinicopathological phenotype and duration of the disease-two important considerations for envisioned therapeutic interventions. ANN NEUROL 2017;81:79-92. © 2016 American Neurological Association.

  3. Diagnostic and Prognostic Value of Human Prion Detection in Cerebrospinal Fluid

    PubMed Central

    Foutz, Aaron; Appleby, Brian S.; Hamlin, Clive; Liu, Xiaoqin; Yang, Sheng; Cohen, Yvonne; Chen, Wei; Blevins, Janis; Fausett, Cameron; Wang, Han; Gambetti, Pierluigi; Zhang, Shulin; Hughson, Andrew; Tatsuoka, Curtis; Schonberger, Lawrence B.; Cohen, Mark L.; Caughey, Byron; Safar, Jiri G.

    2016-01-01

    Objective Several prion amplification systems have been proposed for detection of prions in cerebrospinal fluid (CSF), most recently, the measurements of prion seeding activity with second-generation real-time quaking-induced conversion (RT-QuIC). The objective of this study was to investigate the diagnostic performance of the RT-QuIC prion test in the broad phenotypic spectrum of prion diseases. Methods We performed CSF RT-QuIC testing in 2,141 patients who had rapidly progressive neurological disorders, determined diagnostic sensitivity and specificity in 272 cases which were autopsied, and evaluated the impact of mutations and polymorphisms in the PRNP gene, and Type 1 or Type 2 of human prions on diagnostic performance. Results The 98.5% diagnostic specificity and 92% sensitivity of CSF RT-QuIC in a blinded retrospective analysis matched the 100% specificity and 95% sensitivity of a blind prospective study. The CSF RT-QuIC differentiated 94% of cases of sporadic Creutzfeldt-Jakob disease (sCJD) MM1 from the sCJD MM2 phenotype, and 80% of sCJD VV2 from sCJD VV1. The mixed prion type 1–2 and cases heterozygous for codon 129 generated intermediate CSF RT-QuIC patterns, while genetic prion diseases revealed distinct profiles for each PRNP gene mutation. Interpretation The diagnostic performance of the improved CSF RT-QuIC is superior to surrogate marker tests for prion diseases such as 14-3-3 and Tau proteins and together with PRNP gene sequencing, the test allows the major prion subtypes to be differentiated in vivo. This differentiation facilitates prediction of the clinicopathological phenotype and duration of the disease—two important considerations for envisioned therapeutic interventions. PMID:27893164

  4. Diagnostic delay in narcolepsy type 1: combining the patients' and the doctors' perspectives.

    PubMed

    Taddei, Raquel N; Werth, Esther; Poryazova, Rositsa; Baumann, Christian R; Valko, Philipp O

    2016-12-01

    Narcolepsy type 1 is a neurological disorder characterized by a unique syndrome, including the pathognomonic symptom of cataplexy. The diagnosis can be confirmed by objective measures, such as typical findings in the multiple sleep latency test, reduced or undetectable levels of orexin (hypocretin) in the cerebrospinal fluid, and linkage to a specific HLA haplotype. Nevertheless, the mean time that elapses from symptom onset to the correct diagnosis ranges between 10 and 20 years, and the causes and correlates of this delay are poorly understood. Diagnostic delay was assessed on 52 well-defined patients with narcolepsy type 1, evaluating clinical, electrophysiological and neurochemical parameters and the results of a 41-item questionnaire developed to obtain the patients' perspective on various aspects of the diagnostic process. The mean time gap between disease onset and first medical consultation was 3.2 ± 5.1 years; the mean diagnostic delay was 8.9 ± 11.0 years. Prior to correct diagnosis, patients received a wide variety of misdiagnoses. The self-ratings of the patients revealed that the undiagnosed symptoms caused high levels of anxiety and unjustified criticism by family, friends and employers. Multiple regression analysis identified higher cerebrospinal fluid orexin levels (β = 0.311, P = 0.01), and a longer interval between the onset of excessive daytime sleepiness and cataplexy (β = 0.368, P = 0.002) as independent associates of longer diagnostic delay. The diagnostic delay decreased over the last decades (β = -0.672, P < 0.001). In conclusion, delayed diagnosis of narcolepsy type 1 is very common, associated with many adverse consequences, and requires educational efforts to improve awareness on narcolepsy among healthcare providers and the general population. © 2016 European Sleep Research Society.

  5. Diagnostic accuracy of routine blood examinations and CSF lactate level for post-neurosurgical bacterial meningitis.

    PubMed

    Zhang, Yang; Xiao, Xiong; Zhang, Junting; Gao, Zhixian; Ji, Nan; Zhang, Liwei

    2017-06-01

    To evaluate the diagnostic accuracy of routine blood examinations and Cerebrospinal Fluid (CSF) lactate level for Post-neurosurgical Bacterial Meningitis (PBM) at a large sample-size of post-neurosurgical patients. The diagnostic accuracies of routine blood examinations and CSF lactate level to distinguish between PAM and PBM were evaluated with the values of the Area Under the Curve of the Receiver Operating Characteristic (AUC -ROC ) by retrospectively analyzing the datasets of post-neurosurgical patients in the clinical information databases. The diagnostic accuracy of routine blood examinations was relatively low (AUC -ROC <0.7). The CSF lactate level achieved rather high diagnostic accuracy (AUC -ROC =0.891; CI 95%, 0.852-0.922). The variables of patient age, operation duration, surgical diagnosis and postoperative days (the interval days between the neurosurgery and examinations) were shown to affect the diagnostic accuracy of these examinations. The variables were integrated with routine blood examinations and CSF lactate level by Fisher discriminant analysis to improve their diagnostic accuracy. As a result, the diagnostic accuracy of blood examinations and CSF lactate level was significantly improved with an AUC -ROC value=0.760 (CI 95%, 0.737-0.782) and 0.921 (CI 95%, 0.887-0.948) respectively. The PBM diagnostic accuracy of routine blood examinations was relatively low, whereas the accuracy of CSF lactate level was high. Some variables that are involved in the incidence of PBM can also affect the diagnostic accuracy for PBM. Taking into account the effects of these variables significantly improves the diagnostic accuracies of routine blood examinations and CSF lactate level. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  6. Comparison of Cell Preparations between Commercially Available Filter Cards of the Cytospin with Custom Made Filter Cards.

    PubMed

    Krishnamurthy, Vani; Satish, Suchitha; Doreswamy, Srinivasa Murthy; Vimalambike, Manjunath Gubbanna

    2016-07-01

    Cytological evaluation of body fluids is an important diagnostic technique. Cytocentrifuge has contributed immensely to improve the diagnostic yield of the body fluids. Cytocentrifuge requires a filter card for absorbing the cell free fluid. This is the only consumable which needs to be purchased from the manufacturer at a significant cost. To compare the cell density in cytocentrifuge preparations made from commercially available filter cards with custom made filter cards. This was a prospective analytical study undertaken in department of pathology of a tertiary care centre. A 300 GSM handmade paper with the absorbability similar to the conventional card was obtained and fashioned to suit the filter card slot of the cytospin. Thirty seven body fluids were centrifuged using both conventional and custom made filter card. The cell density was measured as number of cells per 10 high power fields. The median cell density was compared using Mann-Whitney U test. The agreement between the values was analysed using Bland Altman analysis. The median cell count per 10 High power field (HPF) with conventional card was 386 and that with custom made card was 408. The difference was not statistically significant (p = 0.66). There was no significant difference in the cell density and alteration in the morphology between the cell preparations using both the cards. Custom made filter card can be used for cytospin cell preparations of body fluids without loss of cell density or alteration in the cell morphology and at a very low cost.

  7. [Evaluation of the diagnosis value of carcinoembryonic antigen in malignant pleural effusion].

    PubMed

    Yu, Y X; Tong, Z H; Zhou, X X; Liang, L R; Wang, Z; Xu, L L; Wang, X J; Wu, Y B; Li, H J; Lu, Z

    2018-02-06

    Objective: To investigate the diagnostic value of serum and pleural fluid carcinoembryonic antigen (CEA) for malignant pleural effusion (MPE). Methods: The concentration of CEA in serum and pleural fluid of 286 patients with the diagnosis confirmed by pleural biopsy through medical thoracoscopy were retrospectively analyzed. MPE was confirmed in 171 cases which were divided into two groups (adenocarcinoma group with 121cases and non-adenocarcinoma group with 50 cases) and benign pleural effusion in 115 cases. The optimal cutoff for MPE and MPE caused by adenocarcinoma were determined by using the ROC curve. Results: The concentration of serum CEA 12.27(3.80, 58.45) μg/L was significantly higher in MPE caused by adenocarcinoma than that of non-adenocarcinoma 1.91(1.08, 4.55) μg/L and benign effusion 1.32(0.86, 2.27) μg/L (both P <0.001), but there was no statistically significant difference between benign and non-adenocarcinoma effusion ( P =0.728). The concentration of pleural fluid CEA 160.70(30.48, 1 000.00) μg/L was significantly higher in MPE caused by adenocarcinoma than that of non-adenocarcinoma 1.77(0.51, 11.39) μg/L and benign effusion 1.09(0.60, 1.68) μg/L (both P <0.001), and higher in non-adenocarcinoma effusion than that of benign effusion ( P <0.05). The cutoff value of serum and pleural fluid CEA for MPE was 3.10 and 5.83 μg/L, the sensitivity respectively was 67.3% and 74.3%, the specificity respectively was 87.8% and 98.3%, positive predictive value respectively was 89.2% and 98.5%, negative predictive value respectively was 64.3% and 72.0%. The cutoff value of serum and pleural fluid CEA for MPE caused by adenocarcinoma was 3.54 and 7.30 μg/L, the sensitivity respectively was 76.0% and 91.7%, the specificity respectively was 74.0% and 72.0%, positive predictive value respectively was 87.6% and 88.8%, negative predictive value respectively was 56.1% and 78.3%. Conclusions: The concentration of serum and pleural fluid CEA have diagnostic significance to MPE, especially MPE caused by adenocarcinoma. The diagnostic value of pleural fluid CEA is superior to serum CEA.

  8. Diagnostic Accuracy of Ascites Fluid Gross Appearance in Detection of Spontaneous Bacterial Peritonitis.

    PubMed

    Aminiahidashti, Hamed; Hosseininejad, Seyed Mohammad; Montazer, Hosein; Bozorgi, Farzad; Goli Khatir, Iraj; Jahanian, Fateme; Raee, Behnaz

    2014-01-01

    Spontaneous bacterial peritonitis (SBP) as a monomicrobial infection of ascites fluid is one of the most important causes of morbidity and mortality in cirrhotic patients. This study was aimed to determine the diagnostic accuracy of ascites fluid color in detection of SBP in cirrhotic cases referred to the emergency department. Cirrhotic patients referred to the ED for the paracentesis of ascites fluid were enrolled. For all studied patients, the results of laboratory analysis and gross appearance of ascites fluid registered and reviewed by two emergency medicine specialists. The sensitivity, specificity, positive and negative predictive value, and positive and negative likelihood ration of the ascites fluid gross appearance in detection of SBP were measured with 95% confidence interval. The present project was performed in 80 cirrhotic patients with ascites (52.5 female). The mean of the subjects' age was 56.25±12.21 years (35-81). Laboratory findings revealed SBP in 23 (29%) cases. Fifty nine (73%) cases had transparent ascites fluid appearance of whom 17 (29%) ones suffered from SBP. From 21 (26%) cases with opaque ascites appearance, 15 (71%) had SBP. The sensitivity and specificity of the ascites fluid appearance in detection of SBP were 46.88% (Cl: 30.87-63.55) and 87.50% (95% Cl: 75.3-94.14), respectively. It seems that the gross appearance of ascites fluid had poor diagnostic accuracy in detection of SBP and considering its low sensitivity, it could not be used as a good screening tool for this propose.

  9. Diagnostic Performance of Bronchoalveolar Lavage Fluid CD4/CD8 Ratio for Sarcoidosis: A Meta-analysis.

    PubMed

    Shen, Yongchun; Pang, Caishuang; Wu, Yanqiu; Li, Diandian; Wan, Chun; Liao, Zenglin; Yang, Ting; Chen, Lei; Wen, Fuqiang

    2016-06-01

    The usefulness of bronchoalveolar lavage fluid (BALF) CD4/CD8 ratio for diagnosing sarcoidosis has been reported in many studies with variable results. Therefore, we performed a meta-analysis to estimate the overall diagnostic accuracy of BALF CD4/CD8 ratio based on the bulk of published evidence. Studies published prior to June 2015 and indexed in PubMed, OVID, Web of Science, Scopus and other databases were evaluated for inclusion. Data on sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), and diagnostic odds ratio (DOR) were pooled from included studies. Summary receiver operating characteristic (SROC) curves were used to summarize overall test performance. Deeks's funnel plot was used to detect publication bias. Sixteen publications with 1885 subjects met our inclusion criteria and were included in this meta-analysis. Summary estimates of the diagnostic performance of the BALF CD4/CD8 ratio were as follows: sensitivity, 0.70 (95%CI 0.64-0.75); specificity, 0.83 (95%CI 0.78-0.86); PLR, 4.04 (95%CI 3.13-5.20); NLR, 0.36 (95%CI 0.30-0.44); and DOR, 11.17 (95%CI 7.31-17.07). The area under the SROC curve was 0.84 (95%CI 0.81-0.87). There was no evidence of publication bias. Measuring the BALF CD4/CD8 ratio may assist in the diagnosis of sarcoidosis when interpreted in parallel with other diagnostic factors. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  10. Cerebrospinal fluid biomarkers for the diagnosis and prognosis of Parkinson's disease: protocol for a systematic review and individual participant data meta-analysis.

    PubMed

    Eusebi, Paolo; Hansson, Oskar; Paciotti, Silvia; Orso, Massimiliano; Chiasserini, Davide; Calabresi, Paolo; Blennow, Kaj; Parnetti, Lucilla

    2017-11-22

    Idiopathic Parkinson's disease (PD) is a progressive neurodegenerative disorder related to α-synuclein misfolding and aggregation. For this reason, it belongs to the family of 'synucleinopathies', which also includes some other neurological diseases. Although imaging and ancillary investigations may be helpful in the diagnostic workup, the diagnosis of PD mostly relies on the clinician's expertise. Furthermore, there is a need today for markers that can track the disease progression in PD that might improve the evaluation of novel disease-modifying therapies. The cerebrospinal fluid (CSF) has been widely investigated with the purpose of finding useful diagnostic and prognostic biomarkers for PD. This systematic review protocol has been developed according to the Preferred Reporting Items for Systematic reviews and Meta-Analyses Protocol 2015 statement and was registered on the PROSPERO international prospective register of systematic reviews. An international collaboration will be established. We will search the Cochrane Library, Web of Science, Medline and Embase from inception, using appropriate search strategies. Individual participant data from all included studies will be merged into a single database. We will include any study assessing the diagnostic and prognostic role of CSF biomarkers in PD. To evaluate the risk of bias and applicability of primary diagnostic accuracy studies, we will use Quality Assessment of Diagnostic Accuracy Studies-2 and Quality in Prognostic Studies. We will use standard meta-analytic procedures. We will first explore the utility of each CSF biomarker in turn. For each biomarker, we will assess its diagnostic and prognostic utility by means of receiver operating characteristic analysis and regression models. We will then move towards a multivariate approach considering different panels of biomarkers. Our study will not include confidential data, and no intervention will be involved, so ethical approval is not required. The results of the study will be reported in international peer-reviewed journals. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  11. Synovial Fluid α-Defensin as a Biomarker for Peri-Prosthetic Joint Infection: A Systematic Review and Meta-Analysis.

    PubMed

    Li, Bin; Chen, Fei; Liu, Yi; Xu, Guokang

    Total joint arthroplasty (TJA) has been one of the most beneficial interventions for treating patients suffering from joint disorders. However, peri-prosthetic joint infection (PJI) is a serious complication that often accompanies TJA and the diagnosis of PJI is remains difficult. Questions remain regarding whether certain biomarkers can be valuable in the diagnosis of PJI. We conducted our systematic review by searching PubMed, Embase, Web of Science, the Cochrane Library, and Science Direct with the key words "periprosthetic joint infection," "synovial fluid," and "α-defensin." Studies that provided sufficient data to construct 2 × 2 contingency tables were chosen based on inclusion and exclusion criteria. The quality of included studies was assessed according to the revised Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) criteria. The pooled sensitivity, specificity, and diagnostic odds ratio (DOR) were calculated for the included studies. The summary receiver operating characteristic (SROC) curve and the area under the summary receiver operating characteristic (AUSROC) were used to evaluate the overall diagnostic performance. Eight studies were included in this systematic review. Among them four articles were included in meta-analysis. A total of 421 participants were studied in the meta-analysis. The pooled sensitivity, specificity, and DOR were 0.98 (95% confidence interval [CI]: 0.94-1.00), 0.97 (95% CI: 0.95-0.99), and 1095.49 (95% CI: 283.68.58-4230.45), respectively. The AUSROC was 0.9949 (standard error [SE] 0.0095). Synovial fluid α-defensin is a biomarker of high sensitivity and specificity for the diagnosis of PJI.

  12. Dual-energy CT for the diagnosis of gout: an accuracy and diagnostic yield study.

    PubMed

    Bongartz, Tim; Glazebrook, Katrina N; Kavros, Steven J; Murthy, Naveen S; Merry, Stephen P; Franz, Walter B; Michet, Clement J; Veetil, Barath M Akkara; Davis, John M; Mason, Thomas G; Warrington, Kenneth J; Ytterberg, Steven R; Matteson, Eric L; Crowson, Cynthia S; Leng, Shuai; McCollough, Cynthia H

    2015-06-01

    To assess the accuracy of dual-energy CT (DECT) for diagnosing gout, and to explore whether it can have any impact on clinical decision making beyond the established diagnostic approach using polarising microscopy of synovial fluid (diagnostic yield). Diagnostic single-centre study of 40 patients with active gout, and 41 individuals with other types of joint disease. Sensitivity and specificity of DECT for diagnosing gout was calculated against a combined reference standard (polarising and electron microscopy of synovial fluid). To explore the diagnostic yield of DECT scanning, a third cohort was assembled consisting of patients with inflammatory arthritis and risk factors for gout who had negative synovial fluid polarising microscopy results. Among these patients, the proportion of subjects with DECT findings indicating a diagnosis of gout was assessed. The sensitivity and specificity of DECT for diagnosing gout was 0.90 (95% CI 0.76 to 0.97) and 0.83 (95% CI 0.68 to 0.93), respectively. All false negative patients were observed among patients with acute, recent-onset gout. All false positive patients had advanced knee osteoarthritis. DECT in the diagnostic yield cohort revealed evidence of uric acid deposition in 14 out of 30 patients (46.7%). DECT provides good diagnostic accuracy for detection of monosodium urate (MSU) deposits in patients with gout. However, sensitivity is lower in patients with recent-onset disease. DECT has a significant impact on clinical decision making when gout is suspected, but polarising microscopy of synovial fluid fails to demonstrate the presence of MSU crystals. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  13. A Review of Selected Studies That Determine the Physical and Chemical Properties of Saliva in the Field of Dental Treatment

    PubMed Central

    Kubala, Elżbieta; Strzelecka, Paulina; Grzegocka, Marta; Lietz-Kijak, Danuta; Gronwald, Helena; Skomro, Piotr

    2018-01-01

    Physiological whole saliva is a unique body fluid constantly washing the mucous membranes of the mouth, throat, and larynx. Saliva is a clear, slightly acidic mucinous-serous secretion, composed of various electrolytes, small organic substances, proteins, peptides, and polynucleotides. There are many ways to use saliva as a biological fluid (biofluid). The significant advantages of saliva as a unique diagnostic material are its availability and the noninvasive method of collection. The aim of this review is to emphasize the diagnostic value of saliva as a research material in the configuration of its structure and secretion disorders. The data were obtained using the MEDLINE (PubMed) search engine, as well as an additional manual search. The analysis covered 77 articles selected from a group of 1986 publications and initially qualified for devising. The results were evaluated and checked for the correctness of qualifying in accordance with inclusion and exclusion criteria. The diagnostic use of saliva has attracted the attention of many researchers due to its noninvasive nature and relative simplicity of collection. In addition, it should be noted that the determination of chemical and physical saliva parameters can be effectively performed in the patient's presence in the dental office. PMID:29854777

  14. Utility of Cytospin and Cell block Technology in Evaluation of Body Fluids and Urine Samples: A Comparative Study.

    PubMed

    Qamar, Irmeen; Rehman, Suhailur; Mehdi, Ghazala; Maheshwari, Veena; Ansari, Hena A; Chauhan, Sunanda

    2018-01-01

    Cytologic examination of body fluids commonly involves the use of direct or sediment smears, cytocentrifuge preparations, membrane filter preparations, or cell block sections. Cytospin and cell block techniques are extremely useful in improving cell yield of thin serous effusions and urine samples, and ensure high diagnostic efficacy. We studied cytospin preparations and cell block sections prepared from 180 samples of body fluids and urine samples to compare the relative efficiency of cell retrieval, preservation of cell morphology, ease of application of special stains, and diagnostic efficacy. Samples were collected and processed to prepare cytospin smears and cell block sections. We observed that overall, cell yield and preservation of individual cell morphology were better in cytospin preparations as compared to cell blocks, while preservation of architectural pattern was better in cell block sections. The number of suspicious cases also decreased on cell block sections, with increased detection of malignancy. It was difficult to prepare cell blocks from urine samples due to low cellularity. Cytospin technology is a quick, efficient, and cost-effective method of increasing cell yield in hypocellular samples, with better preservation of cell morphology. Cell blocks are better prepared from high cellularity fluids; however, tissue architecture is better studied, with improved rate of diagnosis and decrease in ambiguous results. Numerous sections can be prepared from a small amount of material. Special stains and immunochemical stains can be easily applied to cell blocks. It also provides a source of archival material.

  15. The value of mutational profiling of the cytocentrifugation supernatant fluid from fine-needle aspiration of pancreatic solid mass lesions.

    PubMed

    Deftereos, Georgios; Finkelstein, Sydney D; Jackson, Sara A; Ellsworth, Eric M G; Krishnamurti, Uma; Liu, Yulin; Silverman, Jan F; Binkert, Candy R; Ujevich, Beth A; Mohanty, Alok

    2014-04-01

    Fine-needle aspiration (FNA) of pancreatic solid masses can be significantly impacted by sampling variation. Molecular analysis of tumor DNA can be an aid for more definitive diagnosis. The aim of this study was to evaluate how molecular analysis of the cell-free cytocentrifugation supernatant DNA can help reduce sampling variability and increase diagnostic yield. Twenty-three FNA smears from pancreatic solid masses were performed. Remaining aspirates were rinsed for preparation of cytocentrifuged slides or cell blocks. DNA was extracted from supernatant fluid and assessed for DNA quantity spectrophotometrically and for amplifiability by quantitative PCR (qPCR). Supernatants with adequate DNA were analyzed for mutations using PCR/capillary electrophoresis for a broad panel of markers (KRAS point mutation by sequencing, microsatellite fragment analysis for loss of heterozygosity (LOH) of 16 markers at 1p, 3p, 5q, 9p, 10q, 17p, 17q, 21q, and 22q). In selected cases, microdissection of stained cytology smears and/or cytocentrifugation cellular slides were analyzed and compared. In all, 5/23 samples cytologically confirmed as adenocarcinoma showed detectable mutations both in the microdissected slide-based cytology cells and in the cytocentrifugation supernatant. While most mutations detected were present in both microdissected slides and supernatant fluid specimens, the latter showed additional mutations supporting greater sensitivity for detecting relevant DNA damage. Clonality for individual marker mutations was higher in the supernatant fluid than in microdissected cells. Cytocentrifugation supernatant fluid contains levels of amplifiable DNA suitable for mutation detection and characterization. The finding of additional detectable mutations at higher clonality indicates that supernatant fluid may be enriched with tumor DNA. Molecular analysis of the supernatant fluid could serve as an adjunct method to reduce sampling variability and increase diagnostic yield, especially in cases with a high clinical suspicion for malignancy and limited number of atypical cells in the smears.

  16. Evaluation of fluorescence in situ hybridisation (FISH) for the detection of fungi directly from blood cultures and cerebrospinal fluid from patients with suspected invasive mycoses.

    PubMed

    Da Silva, Roberto Moreira; Da Silva Neto, João Ricardo; Santos, Carla Silvana; Frickmann, Hagen; Poppert, Sven; Cruz, Kátia Santana; Koshikene, Daniela; De Souza, João Vicente Braga

    2015-01-31

    The aim of this study was to evaluate the diagnostic performance of in-house FISH (fluorescence in situ hybridisation) procedures for the direct identification of invasive fungal infections in blood cultures and cerebrospinal fluid (CSF) samples and to compare these FISH results with those obtained using traditional microbiological techniques and PCR targeting of the ITS1 region of the rRNA gene. In total, 112 CSF samples and 30 positive blood cultures were investigated by microscopic examination, culture, PCR-RFLP and FISH. The sensitivity of FISH for fungal infections in CSF proved to be slightly better than that of conventional microscopy (India ink) under the experimental conditions, detecting 48 (instead of 46) infections in 112 samples. The discriminatory powers of traditional microbiology, PCR-RFLP and FISH for fungal bloodstream infections were equivalent, with the detection of 14 fungal infections in 30 samples. However, the mean times to diagnosis after the detection of microbial growth by automated blood culture systems were 5 hours, 20 hours and 6 days for FISH, PCR-RFLP and traditional microbiology, respectively. The results demonstrate that FISH is a valuable tool for the identification of invasive mycoses that can be implemented in the diagnostic routine of hospital laboratories.

  17. The Dynamic Gait Index in Evaluating Patients with Normal Pressure Hydrocephalus for Cerebrospinal Fluid Diversion.

    PubMed

    Chivukula, Srinivas; Tempel, Zachary J; Zwagerman, Nathan T; Newman, W Christopher; Shin, Samuel S; Chen, Ching-Jen; Gardner, Paul A; McDade, Eric M; Ducruet, Andrew F

    2015-12-01

    Diagnosing normal pressure hydrocephalus (NPH) remains challenging. Most clinical tests currently used to evaluate suspected NPH patients for shunt surgery are invasive, require inpatient admission, and are not without complications. An objective, noninvasive, and low-cost alternative would be ideal. A retrospective review was performed of prospectively collected dynamic gait index (DGI) scores, obtained at baseline and on every day of a 3- to 5-day lumbar cerebrospinal fluid (CSF) drainage trial on patients with suspected NPH at our institution. Between 2003 and 2014, 170 patients were suspected to have primary NPH (166, 97.6%) or secondary NPH (4, 2.4%). Using responsiveness to lumbar CSF drainage and subsequent shunting as the reference standard, we found that a baseline DGI ≥ 7 was found to have significant ability in selecting patients for permanent CSF diverting shunt surgery: sensitivity of 84.2% (95% confidence interval [95% CI]: 75.6%-90.2%), specificity of 80.6% (95% CI 70.0%-88.0%), and diagnostic odds ratio of 22.1 (95% CI 9.9-49.3). A baseline DGI ≥ 7 appears to provide an objective, low-cost, noninvasive measure to select patients with suspected NPH for a positive response to CSF diversion with high sensitivity, specificity and diagnostic odds ratio. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Developing a new intelligent system for the diagnosis of tuberculous pleural effusion.

    PubMed

    Li, Chengye; Hou, Lingxian; Sharma, Bishundat Yanesh; Li, Huaizhong; Chen, ChengShui; Li, Yuping; Zhao, Xuehua; Huang, Hui; Cai, Zhennao; Chen, Huiling

    2018-01-01

    In countries with high prevalence of tuberculosis (TB), clinicians often diagnose tuberculous pleural effusion (TPE) by using diagnostic tests, which have not only poor sensitivity, but poor availability as well. The aim of our study is to develop a new artificial intelligence based diagnostic model that is accurate, fast, non-invasive and cost effective to diagnose TPE. It is expected that a tool derived based on the model be installed on simple computer devices (such as smart phones and tablets) and be used by clinicians widely. For this study, data of 140 patients whose clinical signs, routine blood test results, blood biochemistry markers, pleural fluid cell type and count, and pleural fluid biochemical tests' results were prospectively collected into a database. An Artificial intelligence based diagnostic model, which employs moth flame optimization based support vector machine with feature selection (FS-MFO-SVM), is constructed to predict the diagnosis of TPE. The optimal model results in an average of 95% accuracy (ACC), 0.9564 the area under the receiver operating characteristic curve (AUC), 93.35% sensitivity, and 97.57% specificity for FS-MFO-SVM. The proposed artificial intelligence based diagnostic model is found to be highly reliable for diagnosing TPE based on simple clinical signs, blood samples and pleural effusion samples. Therefore, the proposed model can be widely used in clinical practice and further evaluated for use as a substitute of invasive pleural biopsies. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Epidemiology of Meningitis in an HIV-Infected Ugandan Cohort

    PubMed Central

    Rajasingham, Radha; Rhein, Joshua; Klammer, Kate; Musubire, Abdu; Nabeta, Henry; Akampurira, Andrew; Mossel, Eric C.; Williams, Darlisha A.; Boxrud, Dave J.; Crabtree, Mary B.; Miller, Barry R.; Rolfes, Melissa A.; Tengsupakul, Supatida; Andama, Alfred O.; Meya, David B.; Boulware, David R.

    2015-01-01

    There is limited understanding of the epidemiology of meningitis among human immunodeficiency virus (HIV)-infected populations in sub-Saharan Africa. We conducted a prospective cohort study of HIV-infected adults with suspected meningitis in Uganda, to comprehensively evaluate the etiologies of meningitis. Intensive cerebrospiral fluid (CSF) testing was performed to evaluate for bacterial, viral, fungal, and mycobacterial etiologies, including neurosyphilis,16s ribosomal DNA (rDNA) polymerase chain reaction (PCR) for bacteria, Plex-ID broad viral assay, quantitative-PCR for HSV-1/2, cytomegalovirus (CMV), Epstein–Barr virus (EBV), and Toxoplasma gondii; reverse transcription-PCR (RT-PCR) for Enteroviruses and arboviruses, and Xpert MTB/RIF assay. Cryptococcal meningitis accounted for 60% (188 of 314) of all causes of meningitis. Of 117 samples sent for viral PCR, 36% were EBV positive. Among cryptococcal antigen negative patients, the yield of Xpert MTB/RIF assay was 22% (8 of 36). After exclusion of cryptococcosis and bacterial meningitis, 61% (43 of 71) with an abnormal CSF profile had no definitive diagnosis. Exploration of new TB diagnostics and diagnostic algorithms for evaluation of meningitis in resource-limited settings remains needed, and implementation of cryptococcal diagnostics is critical. PMID:25385864

  20. Epidemiology of meningitis in an HIV-infected Ugandan cohort.

    PubMed

    Rajasingham, Radha; Rhein, Joshua; Klammer, Kate; Musubire, Abdu; Nabeta, Henry; Akampurira, Andrew; Mossel, Eric C; Williams, Darlisha A; Boxrud, Dave J; Crabtree, Mary B; Miller, Barry R; Rolfes, Melissa A; Tengsupakul, Supatida; Andama, Alfred O; Meya, David B; Boulware, David R

    2015-02-01

    There is limited understanding of the epidemiology of meningitis among human immunodeficiency virus (HIV)-infected populations in sub-Saharan Africa. We conducted a prospective cohort study of HIV-infected adults with suspected meningitis in Uganda, to comprehensively evaluate the etiologies of meningitis. Intensive cerebrospiral fluid (CSF) testing was performed to evaluate for bacterial, viral, fungal, and mycobacterial etiologies, including neurosyphilis,16s ribosomal DNA (rDNA) polymerase chain reaction (PCR) for bacteria, Plex-ID broad viral assay, quantitative-PCR for HSV-1/2, cytomegalovirus (CMV), Epstein-Barr virus (EBV), and Toxoplasma gondii; reverse transcription-PCR (RT-PCR) for Enteroviruses and arboviruses, and Xpert MTB/RIF assay. Cryptococcal meningitis accounted for 60% (188 of 314) of all causes of meningitis. Of 117 samples sent for viral PCR, 36% were EBV positive. Among cryptococcal antigen negative patients, the yield of Xpert MTB/RIF assay was 22% (8 of 36). After exclusion of cryptococcosis and bacterial meningitis, 61% (43 of 71) with an abnormal CSF profile had no definitive diagnosis. Exploration of new TB diagnostics and diagnostic algorithms for evaluation of meningitis in resource-limited settings remains needed, and implementation of cryptococcal diagnostics is critical. © The American Society of Tropical Medicine and Hygiene.

  1. Pleural effusion: diagnosis, treatment, and management

    PubMed Central

    Karkhanis, Vinaya S; Joshi, Jyotsna M

    2012-01-01

    A pleural effusion is an excessive accumulation of fluid in the pleural space. It can pose a diagnostic dilemma to the treating physician because it may be related to disorders of the lung or pleura, or to a systemic disorder. Patients most commonly present with dyspnea, initially on exertion, predominantly dry cough, and pleuritic chest pain. To treat pleural effusion appropriately, it is important to determine its etiology. However, the etiology of pleural effusion remains unclear in nearly 20% of cases. Thoracocentesis should be performed for new and unexplained pleural effusions. Laboratory testing helps to distinguish pleural fluid transudate from an exudate. The diagnostic evaluation of pleural effusion includes chemical and microbiological studies, as well as cytological analysis, which can provide further information about the etiology of the disease process. Immunohistochemistry provides increased diagnostic accuracy. Transudative effusions are usually managed by treating the underlying medical disorder. However, a large, refractory pleural effusion, whether a transudate or exudate, must be drained to provide symptomatic relief. Management of exudative effusion depends on the underlying etiology of the effusion. Malignant effusions are usually drained to palliate symptoms and may require pleurodesis to prevent recurrence. Pleural biopsy is recommended for evaluation and exclusion of various etiologies, such as tuberculosis or malignant disease. Percutaneous closed pleural biopsy is easiest to perform, the least expensive, with minimal complications, and should be used routinely. Empyemas need to be treated with appropriate antibiotics and intercostal drainage. Surgery may be needed in selected cases where drainage procedure fails to produce improvement or to restore lung function and for closure of bronchopleural fistula. PMID:27147861

  2. Performance of clinical prediction rules for diagnosis of pleural tuberculosis in a high-incidence setting.

    PubMed

    Solari, Lely; Soto, Alonso; Van der Stuyft, Patrick

    2017-10-01

    Diagnosis of pleural tuberculosis (PT) is still a challenge, particularly in resource-constrained settings. Alternative diagnostic tools are needed. We aimed at evaluating the utility of Clinical Prediction Rules (CPRs) for diagnosis of pleural tuberculosis in Peru. We identified CPRs for diagnosis of PT through a structured literature search. CPRs using high-complexity tests, as defined by the FDA, were excluded. We applied the identified CPRs to patients with pleural exudates attending two third-level hospitals in Lima, Peru, a setting with high incidence of tuberculosis. Besides pleural fluid analysis, patients underwent closed pleural biopsy for reaching a final diagnosis through combining microbiological and histopathological criteria. We evaluated the performance of the CPRs against this composite reference standard using classic indicators of diagnostic test validity. We found 15 eligible CPRs, of which 12 could be validated. Most included ADA, age, lymphocyte proportion and protein in pleural fluid as predictive findings. A total of 259 patients were included for their validation, of which 176 (67%) had PT and 50 (19%) malignant pleural effusion. The overall accuracy of the CPRs varied from 41% to 86%. Two had a positive likelihood ratio (LR) above 10, but none a negative LR below 0.1. ADA alone at a cut-off of ≥40 IU attained 87% diagnostic accuracy and had a positive LR of 6.6 and a negative LR of 0.2. Many CPRs for PT are available. In addition to ADA alone, none of them contributes significantly to diagnosis of PT. © 2017 John Wiley & Sons Ltd.

  3. Diagnostic Accuracy of Ascites Fluid Gross Appearance in Detection of Spontaneous Bacterial Peritonitis

    PubMed Central

    Aminiahidashti, Hamed; Hosseininejad, Seyed Mohammad; Montazer, Hosein; Bozorgi, Farzad; Goli Khatir, Iraj; Jahanian, Fateme; Raee, Behnaz

    2014-01-01

    Introduction: Spontaneous bacterial peritonitis (SBP) as a monomicrobial infection of ascites fluid is one of the most important causes of morbidity and mortality in cirrhotic patients. This study was aimed to determine the diagnostic accuracy of ascites fluid color in detection of SBP in cirrhotic cases referred to the emergency department. Methods: Cirrhotic patients referred to the ED for the paracentesis of ascites fluid were enrolled. For all studied patients, the results of laboratory analysis and gross appearance of ascites fluid registered and reviewed by two emergency medicine specialists. The sensitivity, specificity, positive and negative predictive value, and positive and negative likelihood ration of the ascites fluid gross appearance in detection of SBP were measured with 95% confidence interval. Results: The present project was performed in 80 cirrhotic patients with ascites (52.5 female). The mean of the subjects’ age was 56.25±12.21 years (35-81). Laboratory findings revealed SBP in 23 (29%) cases. Fifty nine (73%) cases had transparent ascites fluid appearance of whom 17 (29%) ones suffered from SBP. From 21 (26%) cases with opaque ascites appearance, 15 (71%) had SBP. The sensitivity and specificity of the ascites fluid appearance in detection of SBP were 46.88% (Cl: 30.87-63.55) and 87.50% (95% Cl: 75.3-94.14), respectively. Conclusion: It seems that the gross appearance of ascites fluid had poor diagnostic accuracy in detection of SBP and considering its low sensitivity, it could not be used as a good screening tool for this propose. PMID:26495366

  4. Programmable bio-nano-chip system for saliva diagnostics

    NASA Astrophysics Data System (ADS)

    Christodoulides, Nicolaos; De La Garza, Richard; Simmons, Glennon W.; McRae, Michael P.; Wong, Jorge; Kosten, Thomas R.; Miller, Craig S.; Ebersole, Jeffrey L.; McDevitt, John

    2014-06-01

    This manuscript describes programmable Bio-Nano-Chip (p-BNC) approach that serves as miniaturized assay platform designed for the rapid detection and quantitation of multiple analytes in biological fluids along with the specific applications in salivary diagnostics intended for the point of need (PON). Included here are oral fluid-based tests for local periodontal disease, systemic cardiac disease and multiplexed tests for drugs of abuse.

  5. Combined measurement of synovial fluid α-Defensin and C-reactive protein levels: highly accurate for diagnosing periprosthetic joint infection.

    PubMed

    Deirmengian, Carl; Kardos, Keith; Kilmartin, Patrick; Cameron, Alexander; Schiller, Kevin; Parvizi, Javad

    2014-09-03

    The diagnosis of periprosthetic joint infection remains a challenge. The purpose of this study was to evaluate the combined measurement of the levels of two synovial fluid biomarkers, α-defensin and C-reactive protein (CRP), for the diagnosis of periprosthetic joint infection. One hundred and forty-nine synovial fluid aspirates, including 112 from patients with an aseptic diagnosis and thirty-seven from patients with periprosthetic joint infection, met the inclusion criteria for this prospective study. Synovial fluid aspirates were tested for α-defensin and CRP levels with use of enzyme-linked immunosorbent assay (ELISA). The Musculoskeletal Infection Society (MSIS) definition of periprosthetic joint infection was utilized for the classification of cases as aseptic or infected. Comorbidities, such as inflammatory conditions, that could confound a test for periprosthetic joint infection were documented, but the patients with such comorbidities were included in the study. The combination of synovial fluid α-defensin and CRP tests demonstrated a sensitivity of 97% and a specificity of 100% for the diagnosis of periprosthetic joint infection. Synovial fluid α-defensin tests alone demonstrated a sensitivity of 97% and a specificity of 96% for the diagnosis of periprosthetic joint infection. Synovial fluid CRP tests, with a low threshold of 3 mg/L, reversed all-false positive α-defensin results without affecting the sensitivity of the test. The diagnostic characteristics of these assays were achieved in a population of patients demonstrating a 23% rate of systemic inflammatory diseases (in the series as a whole) and a 27% rate of concurrent antibiotic treatment (in the infection group). The synovial fluid levels of α-defensin in the setting of periprosthetic joint infection were unchanged during concurrent antibiotic treatment. The combined measurement of synovial fluid α-defensin and CRP levels correctly diagnosed 99% of the cases in this study as aseptic or infected. This was achieved despite the inclusion of patients with systemic inflammatory disease and those receiving treatment with antibiotics. Diagnostic Level II. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.

  6. FDNS CFD Code Benchmark for RBCC Ejector Mode Operation: Continuing Toward Dual Rocket Effects

    NASA Technical Reports Server (NTRS)

    West, Jeff; Ruf, Joseph H.; Turner, James E. (Technical Monitor)

    2000-01-01

    Computational Fluid Dynamics (CFD) analysis results are compared with benchmark quality test data from the Propulsion Engineering Research Center's (PERC) Rocket Based Combined Cycle (RBCC) experiments to verify fluid dynamic code and application procedures. RBCC engine flowpath development will rely on CFD applications to capture the multi -dimensional fluid dynamic interactions and to quantify their effect on the RBCC system performance. Therefore, the accuracy of these CFD codes must be determined through detailed comparisons with test data. The PERC experiments build upon the well-known 1968 rocket-ejector experiments of Odegaard and Stroup by employing advanced optical and laser based diagnostics to evaluate mixing and secondary combustion. The Finite Difference Navier Stokes (FDNS) code [2] was used to model the fluid dynamics of the PERC RBCC ejector mode configuration. Analyses were performed for the Diffusion and Afterburning (DAB) test conditions at the 200-psia thruster operation point, Results with and without downstream fuel injection are presented.

  7. Appraisal of transport and deformation in shale reservoirs using natural noble gas tracers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heath, Jason E.; Kuhlman, Kristopher L.; Robinson, David G.

    2015-09-01

    This report presents efforts to develop the use of in situ naturally-occurring noble gas tracers to evaluate transport mechanisms and deformation in shale hydrocarbon reservoirs. Noble gases are promising as shale reservoir diagnostic tools due to their sensitivity of transport to: shale pore structure; phase partitioning between groundwater, liquid, and gaseous hydrocarbons; and deformation from hydraulic fracturing. Approximately 1.5-year time-series of wellhead fluid samples were collected from two hydraulically-fractured wells. The noble gas compositions and isotopes suggest a strong signature of atmospheric contribution to the noble gases that mix with deep, old reservoir fluids. Complex mixing and transport of fracturingmore » fluid and reservoir fluids occurs during production. Real-time laboratory measurements were performed on triaxially-deforming shale samples to link deformation behavior, transport, and gas tracer signatures. Finally, we present improved methods for production forecasts that borrow statistical strength from production data of nearby wells to reduce uncertainty in the forecasts.« less

  8. Supercritical Fuel Measurements

    DTIC Science & Technology

    2012-09-01

    TERMS Fuels, supercritical fluids , stimulated scattering, Brillouin scattering, Rayleigh scattering, elastic properties, thermal properties 16...10 Supercritical Cell and Fluid Handling ....................................................................................... 11...motion in supercritical fluids . Thus, the method can perform diagnostics on the heat transfer of high-temperature and high-pressure fuels, measuring

  9. Patient-Specific Modeling of Hemodynamics: Supporting Surgical Planning in a Fontan Circulation Correction.

    PubMed

    van Bakel, Theodorus M J; Lau, Kevin D; Hirsch-Romano, Jennifer; Trimarchi, Santi; Dorfman, Adam L; Figueroa, C Alberto

    2018-04-01

    Computational fluid dynamics (CFD) is a modeling technique that enables calculation of the behavior of fluid flows in complex geometries. In cardiovascular medicine, CFD methods are being used to calculate patient-specific hemodynamics for a variety of applications, such as disease research, noninvasive diagnostics, medical device evaluation, and surgical planning. This paper provides a concise overview of the methods to perform patient-specific computational analyses using clinical data, followed by a case study where CFD-supported surgical planning is presented in a patient with Fontan circulation complicated by unilateral pulmonary arteriovenous malformations. In closing, the challenges for implementation and adoption of CFD modeling in clinical practice are discussed.

  10. Predicting Fluid Responsiveness by Passive Leg Raising: A Systematic Review and Meta-Analysis of 23 Clinical Trials.

    PubMed

    Cherpanath, Thomas G V; Hirsch, Alexander; Geerts, Bart F; Lagrand, Wim K; Leeflang, Mariska M; Schultz, Marcus J; Groeneveld, A B Johan

    2016-05-01

    Passive leg raising creates a reversible increase in venous return allowing for the prediction of fluid responsiveness. However, the amount of venous return may vary in various clinical settings potentially affecting the diagnostic performance of passive leg raising. Therefore we performed a systematic meta-analysis determining the diagnostic performance of passive leg raising in different clinical settings with exploration of patient characteristics, measurement techniques, and outcome variables. PubMed, EMBASE, the Cochrane Database of Systematic Reviews, and citation tracking of relevant articles. Clinical trials were selected when passive leg raising was performed in combination with a fluid challenge as gold standard to define fluid responders and non-responders. Trials were included if data were reported allowing the extraction of sensitivity, specificity, and area under the receiver operating characteristic curve. Twenty-three studies with a total of 1,013 patients and 1,034 fluid challenges were included. The analysis demonstrated a pooled sensitivity of 86% (95% CI, 79-92), pooled specificity of 92% (95% CI, 88-96), and a summary area under the receiver operating characteristic curve of 0.95 (95% CI, 0.92-0.98). Mode of ventilation, type of fluid used, passive leg raising starting position, and measurement technique did not affect the diagnostic performance of passive leg raising. The use of changes in pulse pressure on passive leg raising showed a lower diagnostic performance when compared with passive leg raising-induced changes in flow variables, such as cardiac output or its direct derivatives (sensitivity of 58% [95% CI, 44-70] and specificity of 83% [95% CI, 68-92] vs sensitivity of 85% [95% CI, 78-90] and specificity of 92% [95% CI, 87-94], respectively; p < 0.001). Passive leg raising retains a high diagnostic performance in various clinical settings and patient groups. The predictive value of a change in pulse pressure on passive leg raising is inferior to a passive leg raising-induced change in a flow variable.

  11. Reactive oxygen species modulator 1, a novel protein, combined with carcinoembryonic antigen in differentiating malignant from benign pleural effusion.

    PubMed

    Chen, Xianmeng; Zhang, Na; Dong, Jiahui; Sun, Gengyun

    2017-05-01

    The differential diagnosis of malignant pleural effusion and benign pleural effusion remains a clinical problem. Reactive oxygen species modulator 1 is a novel protein overexpressed in various human tumors. The objective of this study was to evaluate the diagnostic value of joint detection of reactive oxygen species modulator 1 and carcinoembryonic antigen in the differential diagnosis of malignant pleural effusion and benign pleural effusion. One hundred two consecutive patients with pleural effusion (including 52 malignant pleural effusion and 50 benign pleural effusion) were registered in this study. Levels of reactive oxygen species modulator 1 and carcinoembryonic antigen were measured by enzyme-linked immunosorbent assay and radioimmunoassay, respectively. Results showed that the concentrations of reactive oxygen species modulator 1 both in pleural fluid and serum of patients with malignant pleural effusion were significantly higher than those of benign pleural effusion (both p < 0.05). The diagnostic sensitivity and specificity of pleural fluid reactive oxygen species modulator 1 were 61.54% and 82.00%, respectively, with the optimized cutoff value of 589.70 pg/mL. However, the diagnostic sensitivity and specificity of serum reactive oxygen species modulator 1 were only 41.38% and 86.21%, respectively, with the cutoff value of 27.22 ng/mL, indicating that serum reactive oxygen species modulator 1 may not be a good option in the differential diagnosis of malignant pleural effusion and benign pleural effusion. The sensitivity and specificity of pleural fluid carcinoembryonic antigen were 69.23% and 88.00%, respectively, at the cutoff value of 3.05 ng/mL, while serum carcinoembryonic antigen were 80.77% and 72.00% at the cutoff value of 2.60 ng/mL. The sensitivity could be raised to 88.17% in parallel detection of plural fluid reactive oxygen species modulator 1 and carcinoembryonic antigen concentration, and the specificity could be improved to 97.84% in serial detection.

  12. Screening ultrasonography of 2,204 patients with blunt abdominal trauma in the Wenchuan earthquake.

    PubMed

    Zhou, Jixiang; Huang, Jiwei; Wu, Hong; Jiang, Hui; Zhang, Heqing; Prasoon, Pankaj; Xu, Yinglong; Bai, Yannan; Qiu, Jianguo; Zeng, Yong

    2012-10-01

    Abdominal injuries constitute a small proportion of all earthquake-related traumas; however, it often resulted in fatal hemorrhage. Ultrasonography has been described as an effective triage tool in the evaluation of blunt abdominal trauma. We aimed to present an overview of the diagnostic accuracy of screening ultrasonography for patients with blunt abdominal trauma admitted to various hospitals during the Wenchuan earthquake in China. We retrospectively analyzed the patients with blunt abdominal trauma who underwent ultrasonography after admission to various hospitals. Ultrasonography findings were considered positive if evidence of free fluid or a parenchymal injury was identified. Ultrasonography findings were compared with the findings of computed tomography, diagnostic peritoneal lavage, repeated ultrasonography, cystography, operation, and/or the clinical course. Findings from 2,204 ultrasonographic examinations were evaluated. Findings of 199 ultrasonographic examinations (9.0%) were considered positive. Of the patients, 12 (0.5%) had a false-negative ultrasonographic findings; of this group, 3 (25%) required exploratory laparotomy. Ultrasonography had a sensitivity of 91.9%, specificity of 96.9%, and an accuracy of 96.6% for detection of abdominal injuries. Positive predictive value was 68.3%, and negative predictive value was 99.4%. Screening ultrasonography is highly reliable in the setting of blunt abdominal trauma after earthquake. It should be used as an initial diagnostic modality in the evaluation of most blunt abdominal trauma. Diagnostic study, level III.

  13. Evaluation of Cepheid's Xpert MTB/Rif test on pleural fluid in the diagnosis of pleural tuberculosis in a high prevalence HIV/TB setting.

    PubMed

    Lusiba, John K; Nakiyingi, Lydia; Kirenga, Bruce J; Kiragga, Agnes; Lukande, Robert; Nsereko, Maria; Ssengooba, Willy; Katamba, Achilles; Worodria, William; Joloba, Moses L; Mayanja-Kizza, Harriet

    2014-01-01

    Diagnosis of pleural tuberculosis (TB) using routinely available diagnostic methods is challenging due to the paucibacillary nature of the disease. Histopathology and pleural tissue TB culture involves an invasive procedure which requires expertise and appropriate equipment, both often unavailable in many health units. Xpert MTB/Rif test has been widely evaluated in sputum specimens but data on its performance in pleural TB is scarce. We evaluated the accuracy of Cepheid's Xpert MTB/Rif test on pleural fluid in the diagnosis of pleural TB in Uganda. Consenting adult patients with exudative pleural effusions underwent pleural biopsy and the tissue obtained subjected to Lowenstein-Jensen and mycobacterial growth indicator tube MTB cultures and histopathology. Pleural fluid for Xpert MTB/Rif testing was also collected. Data on socio-demographic characteristics, clinical symptoms, HIV status and CD4 count were also collected. Sensitivity, specificity, positive and negative predictive values of Xpert MTB/Rif test on pleural fluid in pleural TB diagnosis were calculated using pleural tissue MTB culture and/or histopathology as the reference standard. Of the 116 participants [female 50%, mean age 34 (SD ±13], 87/116 (75%) had pleural TB confirmed on pleural tissue culture and/or histopathology. The Xpert MTB/Rif test identified 25 (28.7%) of the 87 confirmed pleural TB cases. The sensitivity and specificity of Xpert MTB/Rif test were 28.7% and 96.6% respectively while the positive and negative predictive values were 96.1% and 31.1% respectively. Xpert MTB/Rif test on pleural fluid does not accurately diagnose pleural TB and therefore cannot be used as an initial evaluation test in patients with suspected pleural TB. New, rapid and accurate tests for the diagnosis of pleural TB are still warranted.

  14. Turning the Page: Advancing Paper-Based Microfluidics for Broad Diagnostic Application.

    PubMed

    Gong, Max M; Sinton, David

    2017-06-28

    Infectious diseases are a major global health issue. Diagnosis is a critical first step in effectively managing their spread. Paper-based microfluidic diagnostics first emerged in 2007 as a low-cost alternative to conventional laboratory testing, with the goal of improving accessibility to medical diagnostics in developing countries. In this review, we examine the advances in paper-based microfluidic diagnostics for medical diagnosis in the context of global health from 2007 to 2016. The theory of fluid transport in paper is first presented. The next section examines the strategies that have been employed to control fluid and analyte transport in paper-based assays. Tasks such as mixing, timing, and sequential fluid delivery have been achieved in paper and have enabled analytical capabilities comparable to those of conventional laboratory methods. The following section examines paper-based sample processing and analysis. The most impactful advancement here has been the translation of nucleic acid analysis to a paper-based format. Smartphone-based analysis is another exciting development with potential for wide dissemination. The last core section of the review highlights emerging health applications, such as male fertility testing and wearable diagnostics. We conclude the review with the future outlook, remaining challenges, and emerging opportunities.

  15. Next-generation confirmatory disease diagnostics

    NASA Astrophysics Data System (ADS)

    Lin, Robert; Gerver, Rachel; Karns, Kelly; Apori, Akwasi A.; Denisin, Aleksandra K.; Herr, Amy E.

    2014-06-01

    Microfluidic tools are advancing capabilities in screening diagnostics for use in near-patient settings. Here, we review three case studies to illustrate the flexibility and analytical power offered by microanalytical tools. We first overview a near-patient tool for detection of protein markers found in cerebrospinal fluid (CSF), as a means to identify the presence of cerebrospinal fluid in nasal mucous - an indication that CSF is leaking into the nasal cavity. Microfluidic design allowed integration of several up-stream preparatory steps and rapid, specific completion of the human CSF protein assay. Second, we overview a tear fluid based assay for lactoferrin, a protein produced in the lacrimal gland, then secreted into tear fluid. Tear Lf is a putative biomarker for primary SS. A critical contribution of this and related work being measurement of Lf, even in light of well-known and significant matrix interactions and losses during the tear fluid collection and preparation. Lastly, we review a microfluidic barcode platform that enables rapid measurement of multiple infectious disease biomarkers in human sera. The assay presents a new approach to multiplexed biomarker detection, yet in a simple straight microchannel - thus providing a streamlined, simplified microanalytical platform, as is relevant to robust operation in diagnostic settings. We view microfluidic design and analytical chemistry as the basis for emerging, sophisticated assays that will advance not just screening diagnostic technology, but confirmatory assays, sample preparation and handling, and thus introduction and utilization of new biomarkers and assay formats.

  16. Diagnostic yield and safety of closed needle pleural biopsy in exudative pleural effusion.

    PubMed

    Rajawat, Govind Singh; Batra, Supreet; Takhar, Rajendra Prasad; Rathi, Lalit; Bhandari, Chand; Gupta, Manohar Lal

    2017-01-01

    Closed pleural biopsy was previously considered a procedure of choice in cases of undiagnosed pleural effusion with good efficacy. Currently, the closed pleural biopsy has been replaced by thoracoscopic biopsy but not easily available in resource-limited setups. The objective of this study was to analyze the diagnostic yield and safety of closed needle pleural biopsy in exudative pleural effusion and assessment of patients' characteristics with the yield of pleural biopsy. This was a cross-sectional study. This study was conducted at Institute of Respiratory Diseases, SMS Medical College, Jaipur, a tertiary care center of West India. A total of 250 cases of pleural effusion were evaluated with complete pleural fluid biochemical, microbiological, and cytological examination. Out of these 250 patients, 59 were excluded from the study as the diagnosis could be established on initial pleural fluid examination. The remaining (191) patients were considered for closed pleural biopsy with Abrams pleural biopsy needle. The main outcome measure was diagnostic yield in the form of confirming diagnosis. Out of the 191 patients with exudative lymphocytic pleural effusion, 123 (64.40%) were diagnosed on the first pleural biopsy. Among the remaining 68 patients, 22 patients had repeat pleural biopsy with a diagnostic yield of 59.9%. The overall pleural biopsy could establish the diagnosis in 136 (71.20%) patients with pleural effusion. The most common diagnosis on pleural biopsy was malignancy followed by tuberculosis. Closed pleural biopsy provides diagnostic yield nearly comparative to thoracoscopy in properly selected patients of pleural effusions. In view of good yield, low cost, easy availability, and very low complication rate, it should be used routinely in all cases of undiagnosed exudative lymphocytic pleural effusion. There was no comparison with a similar group undergoing thoracoscopic pleural biopsy.

  17. Development of the Technology of Vortex Diagnostics to Improve the Safety of Operation of Nuclear Reactors

    NASA Astrophysics Data System (ADS)

    Mitrofanova, O. V.; Ivlev, O. A.; Pozdeeva, I. G.; Urtenov, D. S.

    2017-11-01

    The results of studies are aimed at developing theoretical foundations and instrumentation system to ensure a technology of vortex diagnostics of the state of flows of fluids for nuclear power installations with power water reactors and fast neutrons reactors with liquid-metal coolants. The technology of vortex diagnostics is based on the study of acoustic, magneto-hydrodynamic and resonant effects related to the formation of stable vortex structures. For creation a system of monitoring and diagnostics of the crisis phenomena due to hydrodynamics of the flow, it is proposed to use acoustic method to record the radiation of elastic waves in the fluids caused by the dynamic local rearrangement of its structure.

  18. Toxicological evaluation of two children diagnosed as Munchausen syndrome by proxy.

    PubMed

    Türkmen, Zeynep; Ziyalar, Neylan; Tari, Itir; Mercan, Selda; Kayiran, Sinan Mahir; Sener, Dicle; Cengiz, Salih; Akçakaya, Necla

    2012-01-01

    Munchausen syndrome by proxy is a kind of child abuse in which affected children are often hospitalized for long periods and endure repetitive, painful and expensive diagnostic attempts. We present herein two toxicologically confirmed cases of Munchausen syndrome by proxy. Case 1 is a 16-month-old male who had fever, peripheral cyanosis, tremor, and reported cardiac arrest. Symptoms recurred in the hospital when the mother administered fluids. Toxicology detected 3.5 ng/ml mercury (Hg) in the fluid and 9.4 microg Hg/g creatinine in the urine. Case 2 is a 14-year-old female who had irregular blood findings and multiple hospitalizations. Serum analysis detected warfarin. Both mothers were transferred to psychiatric care. Munchausen syndrome by proxy should be suspected when clinical/laboratory findings are negative, illness descriptions are inconsistent, and frequent hospitalization yields no diagnosis. Psychiatric evaluation and toxicological analysis are recommended.

  19. An evaluation of serological tests in the diagnosis of bovine brucellosis in naturally infected cattle in KwaZulu-Natal province in South Africa.

    PubMed

    Chisi, Songelwayo L; Marageni, Yoanda; Naidoo, Prebashni; Zulu, Gloria; Akol, George W; Van Heerden, Henriette

    2017-02-28

    The diagnostic sensitivity (DSe) of the Rose Bengal test (RBT), the complement fixation test (CFT), the serum agglutination test (SAT), the competitive enzyme-linked immunosorbent assay (cELISA) and the indirect ELISA (iELISA) were determined in naturally infected cattle in KwaZulu-Natal province of South Africa with known infectious status from culture (gold standard). Natural brucellosis infection status of animals was determined by culturing and identification of Brucella abortus biovar 1 from abomasal fluid, milk, hygroma fluid, lymph nodes or uterine discharges samples. The diagnostic specificity (DSp) of the tests mentioned above was determined using samples from known negative herds. There was no statistically significant difference between the tests in their ability to diagnose brucellosis. The RBT and iELISA had the highest DSe of 95.8%, whereas RBT and CFT had the highest DSp of 100%. In South African laboratories, the RBT and CFT serological tests are used, because of the cost efficacy of CFT when compared to the less labour intensive but more expensive iELISA.

  20. [Alzheimer's disease cerebro-spinal fluid biomarkers: A clinical research tool sometimes useful in daily clinical practice of memory clinics for the diagnosis of complex cases].

    PubMed

    Magnin, E; Dumurgier, J; Bouaziz-Amar, E; Bombois, S; Wallon, D; Gabelle, A; Lehmann, S; Blanc, F; Bousiges, O; Hannequin, D; Jung, B; Miguet-Alfonsi, C; Quillard, M; Pasquier, F; Peoc'h, K; Laplanche, J-L; Hugon, J; Paquet, C

    2017-04-01

    The role of biomarkers in clinical research was recently highlighted in the new criteria for the diagnosis of Alzheimer's disease. Cerebro-spinal fluid (CSF) biomarkers (total Tau protein, threonine 181 phosphorylated Tau protein and amyloid Aβ1-42 peptide) are associated with cerebral neuropathological lesions observed in Alzheimer's disease (neuronal death, neurofibrillary tangle with abnormal Tau deposits and amyloid plaque). Aβ1-40 amyloid peptide dosage helps to interpret Aβ1-42 results. As suggested in the latest international criteria and the French HAS (Haute Autorité de santé) recommendations, using theses CSF biomarkers should not be systematic but sometimes could be performed to improve confidence about the diagnostic of Alzheimer's disease in young subjects or in complex clinical situations. Future biomarkers actually in development will additionally help in diagnostic process (differential diagnosis) and in prognostic evaluation of neurodegenerative diseases. Copyright © 2016 Société Nationale Française de Médecine Interne (SNFMI). Published by Elsevier SAS. All rights reserved.

  1. Optimization of FNAC findings as a preoperative diagnostic aid for odontogenic cysts.

    PubMed

    Jain, Garima; Shetty, Pushparaja

    2015-01-01

    Fine-needle aspiration cytology (FNAC) is not a definitive preoperative diagnostic procedure done for all cases of odontogenic cysts. This is because of the inconsistent results obtained with it. This study was done to optimize FNAC findings and help in preoperative characterization of odontogenic cysts. Cystic fluid was collected and centrifuged from 50 odontogenic cysts that were planned for excision. Three smears were prepared from the cell sediment obtained after centrifugation and stained. The stained sections were examined for presence and type of epithelial cells, to formulate a preopererative diagnosis. Epithelial cells were detected in 46% cases in smear 1, 48% cases in smear 2, and 52% cases in smear 3. When all three smears from one case were studied, 86% cases showed epithelial cells for evaluation. Cystic aspirate should be centrifuged and the entire cell sediment should be examined by making multiple smears for evaluation of cystic epithelial lining cells.

  2. Can quantity of amniotic fluid reliably predict postnatal renal function in boys with posterior urethral valves: a decision curve analysis.

    PubMed

    Harper, Luke; Waubant, Alice; Vignes, Julien; Amat, Sara; Dobremez, Eric; Lefevre, Yan; Ferdynus, Cyril

    2017-09-01

    Prenatal management of male fetuses with suspected posterior urethral valves depends on reliable markers for postnatal long-term renal function. Whether ultrasound parameters, including the presence or absence of oligohydramnios, are reliable remains the subject of debate. We decided to evaluate the reliability of quantity of amniotic fluid to predict postnatal renal function using decision curve analysis (DCA), a method for evaluating the clinical utility of a diagnostic test. We analyzed retrospectively 51 male fetuses born with prenatally suspected posterior urethral valves between 2009 and 2012. We studied the relationship between quantity of amniotic fluid on prenatal ultrasound and the nadir creatinine during the first year of life as a proxy of postnatal renal function using DCA. Twelve fetuses presented with prenatal oligohydramnios. Thirty-one children had a normal nadir creatinine, of which one had prenatal oligohydramnios (3.2%). Thirteen had a nadir creatinine between 35 and 75 μmol/L, of which four had prenatal oligohydramnios (30.8%). Seven had a nadir creatinine >75 μmol/L, all of them had prenatal oligohydramnios. In this retrospective study, DCA confirms the relationship between prenatal quantity of amniotic fluid volume and postnatal renal function. © 2017 John Wiley & Sons, Ltd. © 2017 John Wiley & Sons, Ltd.

  3. Parkinson's Disease Diagnostic Observations (PADDO): study rationale and design of a prospective cohort study for early differentiation of parkinsonism.

    PubMed

    van Rumund, Anouke; Aerts, Marjolein B; Esselink, Rianne A J; Meijer, Frederick J A; Verbeek, Marcel M; Bloem, Bastiaan R

    2018-05-16

    Differentiation of Parkinson's disease (PD) from the various types of atypical parkinsonism (AP) such as multiple system atrophy (MSA), progressive supranuclear palsy (PSP), dementia with Lewy bodies (DLB), corticobasal syndrome (CBS) and vascular parkinsonism (VP), can be challenging, especially early in the disease course when symptoms overlap. A major unmet need in the diagnostic workup of these disorders is a diagnostic tool that differentiates the various disorders, preferably in the earliest disease stages when the clinical presentation is similar. Many diagnostic tests have been evaluated, but their added value was studied mostly in retrospective case-control studies that included patients with a straightforward clinical diagnosis. Here, we describe the design of a prospective cohort study in patients with parkinsonism in an early disease stage who have an uncertain clinical diagnosis. Our aim is to evaluate the diagnostic accuracy of (1) detailed clinical examination by a movement disorder specialist, (2) magnetic resonance imaging (MRI) techniques and (3) cerebrospinal fluid (CSF) biomarkers. Patients with parkinsonism with an uncertain clinical diagnosis and a disease course less than three years will be recruited. Patients will undergo extensive neurological examination, brain MRI including conventional and advanced sequences, and a lumbar puncture. The diagnosis (including level of certainty) will be defined by a movement disorders expert, neuroradiologist and neurochemist based on clinical data, MRI results and CSF results, respectively. The clinical diagnosis after three years' follow-up will serve as the "gold standard" reference diagnosis, based on consensus criteria and as established by two movement disorder specialists (blinded to the test results). Diagnostic accuracy of individual instruments and added value of brain MRI and CSF analysis after evaluation by a movement disorder expert will be calculated, expressed as the change in percentage of individuals that are correctly diagnosed with PD or AP. This study will yield new insights into the diagnostic value of clinical evaluation by a movement disorder specialist, brain MRI and CSF analysis in discriminating PD from AP in early disease stages. The outcome has the potential to help clinicians in choosing the optimal diagnostic strategy for patients with an uncertain clinical diagnosis. NCT01249768, registered November 26 2010.

  4. Stationary microfluidics: molecular diagnostic assays by moving magnetic beads through non-moving liquids

    NASA Astrophysics Data System (ADS)

    Becker, Holger; Carstens, Cornelia; Kuhlmeier, Dirk; Sandetskaya, Natalia; Schröter, Nicole; Zilch, Christian; Gärtner, Claudia

    2013-03-01

    Commonly, microfluidic devices are based on the movement of fluids. For molecular diagnostics assays which often include steps like PCR, this practically always involves a more or less complicated set of external pumps, valves and liquid controls. In the presented paper, we follow a different approach in which the fluid after sample introduction remains stationary and the main bioactive sample molecules are moved through a chain of reaction compartments which contain the different reagents necessary for the assay. The big advantage of this concept is the lack of any external fluid actuation/control. Results on sample carry-over experiments and complete assays will be given.

  5. Utility of Cytospin and Cell block Technology in Evaluation of Body Fluids and Urine Samples: A Comparative Study

    PubMed Central

    Qamar, Irmeen; Rehman, Suhailur; Mehdi, Ghazala; Maheshwari, Veena; Ansari, Hena A.; Chauhan, Sunanda

    2018-01-01

    Background: Cytologic examination of body fluids commonly involves the use of direct or sediment smears, cytocentrifuge preparations, membrane filter preparations, or cell block sections. Cytospin and cell block techniques are extremely useful in improving cell yield of thin serous effusions and urine samples, and ensure high diagnostic efficacy. Materials and Methods: We studied cytospin preparations and cell block sections prepared from 180 samples of body fluids and urine samples to compare the relative efficiency of cell retrieval, preservation of cell morphology, ease of application of special stains, and diagnostic efficacy. Samples were collected and processed to prepare cytospin smears and cell block sections. Results: We observed that overall, cell yield and preservation of individual cell morphology were better in cytospin preparations as compared to cell blocks, while preservation of architectural pattern was better in cell block sections. The number of suspicious cases also decreased on cell block sections, with increased detection of malignancy. It was difficult to prepare cell blocks from urine samples due to low cellularity. Conclusions: Cytospin technology is a quick, efficient, and cost-effective method of increasing cell yield in hypocellular samples, with better preservation of cell morphology. Cell blocks are better prepared from high cellularity fluids; however, tissue architecture is better studied, with improved rate of diagnosis and decrease in ambiguous results. Numerous sections can be prepared from a small amount of material. Special stains and immunochemical stains can be easily applied to cell blocks. It also provides a source of archival material. PMID:29643653

  6. Collection fluid helps preservation in voided urine cytology.

    PubMed

    Raistrick, J; Shambayati, B; Dunsmuir, W

    2008-04-01

    Degenerative change caused by delay in processing contributes to false-negative and false-positive diagnosis of urothelial carcinoma in cytology. The aim of the study was to see if the use of a collection fluid for urine samples made a significant difference to urine cytology diagnosis, and if one was better suited for routine use in the hospital laboratory. Three cell collection fluids were evaluated by analysing the preservation and degeneration of cells in urine samples, as was the routine preparation which did not use a collection fluid. In the design study 50 voided urine specimens were taken at random from the hospital haematuria clinic. Three commercially available collection fluids cytolyt, cytospin and cytoRich Blue and the hospital's routine conventional preparation of urine were compared. The degree of degeneration, and so preservation, was assessed by a table of chosen criteria; then ranked and analysed by Friedman's nonparametric test, at P = 0.05. A second table showing the cell content of each slide was also made. These showed no significant diagnostic difference between the collection fluids, but there was a significant difference between the collection fluids and the routine preparation. Minor differences that do not affect diagnosis, such as crystals and ghost red blood cells, were noted in cytospin and cytoRich Blue. It is recommended that a collection fluid is used. This choice should be made after health and safety issues and cost are considered.

  7. Evaluation of a monoclonal antibody-based latex agglutination test for diagnosis of cryptococcosis: comparison with two tests using polyclonal antibodies.

    PubMed Central

    Temstet, A; Roux, P; Poirot, J L; Ronin, O; Dromer, F

    1992-01-01

    Cryptococcal antigen detection has become a routine biological test performed for patients with AIDS. The poor prognosis of cryptococcosis explains the need for reliable tests. We evaluated the performances of a newly commercialized agglutination test that uses a monoclonal antibody specific for cryptococcal capsular polysaccharide (Pastorex Cryptococcus; Sanofi-Diagnostics Pasteur, Marnes-la-Coquette, France) and compared them with those of tests that use polyclonal immune sera (Cryptococcal Antigen Latex Agglutination System, Meridian Diagnostics, Inc., Cincinnati, Ohio; and Crypto-LA, International Biological Labs Inc., Cranbury, N.J.). The sensitivities and specificities of the tests were compared by using purified polysaccharides and yeast suspensions. Clinical specimens (131 serum samples, 41 cerebrospinal fluid samples, 34 urine samples, and 19 bronchoalveolar lavage samples) from 87 human immunodeficiency virus-positive subjects with (40 patients) and without (47 patients) culture-proven cryptococcosis were retrospectively tested during a blinded study. The effect of pronase treatment of samples was assessed for Pastorex Cryptococcus and the Cryptococcal Antigen Latex Agglutination System, and the antigen titers were compared. Our results show that (i) during the screening, concordance among the three tests was 97%; (ii) the use of pronase enhanced both the sensitivities and specificities of the Pastorex Cryptococcus test; (iii) titers agreed for 67% of the cerebrospinal fluid samples and 60% of the serum samples; and (iv) cryptococcosis was detected equally well with Pastorex Cryptococcus and with the other tests, whatever the infecting serotype (A, B, or D). The meaning of in vitro sensitivity and the relationship between titers and sensitivity are discussed. The results show that Pastorex Cryptococcus is a rapid and reliable test for the detection of cryptococcal antigen in body fluids and suggest that kits cannot be used interchangeably to monitor antigen titers in patients. PMID:1400951

  8. 21 CFR 872.1500 - Gingival fluid measurer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Gingival fluid measurer. 872.1500 Section 872.1500 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1500 Gingival fluid measurer. (a) Identification...

  9. 21 CFR 872.1500 - Gingival fluid measurer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Gingival fluid measurer. 872.1500 Section 872.1500 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1500 Gingival fluid measurer. (a) Identification...

  10. Optimising the utility of pleural fluid adenosine deaminase for the diagnosis of adult tuberculous pleural effusion in Hong Kong.

    PubMed

    Chang, K C; Chan, M C; Leung, W M; Kong, F Y; Mak, C M; Chen, S Pl; Yu, W C

    2018-02-01

    Pleural fluid adenosine deaminase level can be applied to rapidly detect tuberculous pleural effusion. We aimed to establish a local diagnostic cut-off value for pleural fluid adenosine deaminase to identify patients with tuberculous pleural effusion, and optimise its utility. We retrospectively reviewed the medical records of consecutive adults with pleural fluid adenosine deaminase level measured by the Diazyme commercial kit (Diazyme Laboratories, San Diego [CA], United States) during 1 January to 31 December 2011 in a cluster of public hospitals in Hong Kong. We considered its level alongside early (within 2 weeks) findings in pleural fluid and pleural biopsy, with and without applying Light's criteria in multiple scenarios. For each scenario, we used the receiver operating characteristic curve to identify a diagnostic cut-off value for pleural fluid adenosine deaminase, and estimated its positive and negative predictive values. A total of 860 medical records were reviewed. Pleural effusion was caused by congestive heart failure, chronic renal failure, or hypoalbuminaemia caused by liver or kidney diseases in 246 (28.6%) patients, malignancy in 198 (23.0%), non-tuberculous infection in 168 (19.5%), tuberculous pleural effusion in 157 (18.3%), and miscellaneous causes in 91 (10.6%). All those with tuberculous pleural effusion had a pleural fluid adenosine deaminase level of ≤100 U/L. When analysis was restricted to 689 patients with pleural fluid adenosine deaminase level of ≤100 U/L and early negative findings for malignancy and non-tuberculous infection in pleural fluid, the positive predictive value was significantly increased and the negative predictive value non-significantly reduced. Using this approach, neither additionally restricting analysis to exudates by Light's criteria nor adding closed pleural biopsy would further enhance predictive values. As such, the diagnostic cut-off value for pleural fluid adenosine deaminase is 26.5 U/L, with a sensitivity of 87.3%, specificity of 93.2%, positive predictive value of 79.2%, negative predictive value of 96.1%, and accuracy of 91.9%. Sex, age, and co-morbidity did not significantly affect prediction of tuberculous pleural effusion using the cut-off value. We have established a diagnostic cut-off level for pleural fluid adenosine deaminase in the diagnosis of tuberculous pleural effusion by restricting analysis to a level of ≤100 U/L, and considering early pleural fluid findings for malignancy and non-tuberculous infection, but not Light's criteria.

  11. Clinical validity of cerebrospinal fluid Aβ42, tau, and phospho-tau as biomarkers for Alzheimer's disease in the context of a structured 5-phase development framework.

    PubMed

    Mattsson, Niklas; Lönneborg, Anders; Boccardi, Marina; Blennow, Kaj; Hansson, Oskar

    2017-04-01

    Novel diagnostic criteria for Alzheimer's disease (AD) incorporate biomarkers, but their maturity for implementation in clinical practice at the prodromal stage (mild cognitive impairment [MCI]) is unclear. Here, we evaluate cerebrospinal fluid (CSF) β-amyloid 42 (Aβ42), total tau, and phosphorylated tau in the light of a 5-phase framework for biomarker development. Ample evidence is available for phase 1 (identifying useful leads) and phase 2 (assessing the accuracy for AD dementia versus controls) for CSF biomarkers. Phase 3 (utility in MCI) is partially achieved. In cohorts with long follow-up time, CSF Aβ42, total tau, and phosphorylated tau have high diagnostic accuracy for MCI due to AD. Phase 4 (performance in real world) is ongoing, and phase 5 studies (quantify impact and costs) are to come. Our results highlight priorities to pursue and to enable the proper use of CSF biomarkers in the clinic. Priorities are to reduce measurement variability by introduction of fully automated assay systems; to increase diagnostic specificity toward non-AD neurocognitive diseases at the MCI stage; and to clarify the role of CSF biomarkers versus other biomarker modalities in clinical practice and in design of clinical trials. These efforts are currently ongoing. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Diagnostic utility of the cell block method versus the conventional smear study in pleural fluid cytology.

    PubMed

    Shivakumarswamy, Udasimath; Arakeri, Surekha U; Karigowdar, Mahesh H; Yelikar, Br

    2012-01-01

    The cytological examinations of serous effusions have been well-accepted, and a positive diagnosis is often considered as a definitive diagnosis. It helps in staging, prognosis and management of the patients in malignancies and also gives information about various inflammatory and non-inflammatory lesions. Diagnostic problems arise in everyday practice to differentiate reactive atypical mesothelial cells and malignant cells by the routine conventional smear (CS) method. To compare the morphological features of the CS method with those of the cell block (CB) method and also to assess the utility and sensitivity of the CB method in the cytodiagnosis of pleural effusions. The study was conducted in the cytology section of the Department of Pathology. Sixty pleural fluid samples were subjected to diagnostic evaluation for over a period of 20 months. Along with the conventional smears, cell blocks were prepared by using 10% alcohol-formalin as a fixative agent. Statistical analysis with the 'z test' was performed to identify the cellularity, using the CS and CB methods. Mc. Naemer's χ(2)test was used to identify the additional yield for malignancy by the CB method. Cellularity and additional yield for malignancy was 15% more by the CB method. The CB method provides high cellularity, better architectural patterns, morphological features and an additional yield of malignant cells, and thereby, increases the sensitivity of the cytodiagnosis when compared with the CS method.

  13. STS-41 crewmembers conduct DSO 0472 Intraocular Pressure on OV-103's middeck

    NASA Image and Video Library

    1990-10-10

    STS-41 crewmembers conduct Detailed Supplementary Objective (DSO) 0472 Intraocular Pressure on the middeck of Discovery, Orbiter Vehicle (OV) 103. Mission Specialist (MS) William M. Shepherd rests his head on the stowed treadmill while Pilot Robert D. Cabana, holding Shepherd's eye open, prepares to measure Shepherd's intraocular pressure using a tono pen (in his right hand). Objectives include: establishing a database of changes in intraocular pressures that can be used to evaluate crew health; validating ten degree head down bedrest as a model for cephalad fluid shifts in microgravity; facilitating the interpretation of data by providing a quantative measure of microgravity induced cephalad fluid shifts; and validating the tono pen as an effective tool for diagnostic and scientific data collection.

  14. 21 CFR 872.1500 - Gingival fluid measurer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1500 Gingival fluid measurer. (a) Identification... sulcus (depression between the tooth and gums) to determine if there is a gingivitis condition. (b...

  15. 21 CFR 872.1500 - Gingival fluid measurer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1500 Gingival fluid measurer. (a) Identification... sulcus (depression between the tooth and gums) to determine if there is a gingivitis condition. (b...

  16. 21 CFR 872.1500 - Gingival fluid measurer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1500 Gingival fluid measurer. (a) Identification... sulcus (depression between the tooth and gums) to determine if there is a gingivitis condition. (b...

  17. Aspergillus Galactomannan Enzyme Immunoassay and Quantitative PCR for Diagnosis of Invasive Aspergillosis with Bronchoalveolar Lavage Fluid

    PubMed Central

    Musher, Benjamin; Fredricks, David; Leisenring, Wendy; Balajee, S. Arunmozhi; Smith, Caitlin; Marr, Kieren A.

    2004-01-01

    Invasive pulmonary aspergillosis (IPA) is frequent and often fatal in hematopoietic stem cell transplant patients. Diagnosis requires microbiological or histopathologic demonstration of the organism in tissues; however, cultivation of Aspergillus species from respiratory secretions has low diagnostic sensitivity. Assays to detect Aspergillus antigen or DNA in bronchoalveolar lavage (BAL) fluid could facilitate earlier diagnosis, thereby guiding optimal therapy and obviating the need for additional costly and potentially morbid diagnostic evaluation. We evaluated the performance of a galactomannan enzyme immunoassay (GM EIA; Bio-Rad) by using a range of index cutoffs to define positivity and a quantitative PCR (qPCR) assay for the detection of Aspergillus species from BAL samples of patients with proven and probable IPA (case patients; n = 49) and without IPA (control patients; n = 50). The sensitivity of the GM EIA was 61% with an index cutoff of 1.0 and 76% with an index cutoff of 0.5; the corresponding specificities were 98 and 94%, respectively. The sensitivity and specificity of qPCR assay were 67 and 100%, respectively. The sensitivity with 22 culture-negative BAL specimens from patients with IPA was 41% for GM EIA with an index cutoff of 1.0, 59% for GM EIA with an index cutoff of 0.5, and 36% for qPCR assay. GM EIA indices and DNA quantities corresponded to BAL fungal burdens, with culture-positive samples having larger amounts of antigen and DNA compared to culture-negative samples. GM EIA and qPCR assay add to the sensitivity of BAL for diagnosing IPA in high-risk patients, with excellent specificity. Adjunctive use of these tests may reduce dependence on invasive diagnostic procedures. PMID:15583275

  18. Biomarkers in the evolution of multiple sclerosis.

    PubMed

    Berger, Thomas

    2017-11-01

    Nonimaging biomarkers can be applied in differential diagnosis, evaluation of disease progression and therapy monitoring of multiple sclerosis (MS). Presence of oligoclonal IgG bands in cerebrospinal fluid is a diagnostic element and a negative predictor of MS evolution. AQP4 antibodies are pathogenic and diagnostic for neuromyelitis optica spectrum disorder. Antibodies to myelin oligodendrocyte glycoprotein develop in about 50% of predominantly pediatric patients with acute disseminated encephalomyelitis, but their possible role in pathogenesis is unknown. Currently, there are no individualized biomarkers suitable to track disease progression. Neutralizing antibodies against IFN-β, natalizumab and daclizumab arise with variable frequency and reduce treatment efficacy. The anti-John Cunningham virus antibody index has potential as a biomarker for risk of progressive multifocal leukoencephalopathy.

  19. Comparative Assessment of Conventional Papanicolaou and Modified Ultrafast Papanicolaou Stains in Fine Needle Aspiration Samples and Body Fluids.

    PubMed

    Arul, P; Eniya, S; Pushparaj, Magesh; Masilamani, Suresh; Kanmani, P; Lingasamy, C

    2018-01-01

    Conventional Papanicolaou (Pap) stain has undergone many modifications; of these, ultrafast Pap stain is the most popular as it shortens the turnaround time of reporting. Application of modified ultrafast Pap (MUFP) stain in the evaluation of fine needle aspiration (FNA) samples and body fluids are scanty. To evaluate the utility of MUFP stain in various FNA samples and body fluids and compare the findings with those of conventional Pap stain. In this cross-sectional study, two wet-fixed and two airdried smears from each sample [301 samples (255 FNA samples and 46 body fluids)] were prepared and stained by the conventional Pap and MUFP stains, respectively. Concordant and discordant rate was calculated. Quality index (QI) of MUFP stain was assessed by background, overall staining, cell morphology, and nuclear characteristics. MUFP-stained smears were also categorized into excellent, good, and fair. The concordance rate for MUFP stain was 100%. QI of MUFP stain for breast, thyroid, lymph node, soft tissue, salivary gland, and body fluids was 0.9, 0.93, 0.95, 1, 0.94, and 1, respectively. Excellent quality of stain was noted in 53.2% and good in 24.6% of the cases allowing easy diagnosis. In 22.2% of fair cases, diagnosis was possible with some difficulties. Our study concluded that MUFP stain could be considered as a rapid and reliable diagnostic tool and can be applied on a regular basis in FNA samples and body fluids to offer immediate diagnosis. However, caution should be taken while reporting certain MUFP-stained smears to avoid over/under diagnosis.

  20. Combined use of Kappa Free Light Chain Index and Isoelectrofocusing of Cerebro-Spinal Fluid in Diagnosing Multiple Sclerosis: Performances and Costs.

    PubMed

    Crespi, Ilaria; Sulas, Maria Giovanna; Mora, Riccardo; Naldi, Paola; Vecchio, Domizia; Comi, Cristoforo; Cantello, Roberto; Bellomo, Giorgio

    2017-03-01

    Isoelectrofocusing (IEF) to detect oligoclonal bands (OBCs) in cerebrospinal fluid (CSF) is the gold standard approach for evaluating intrathecal immunoglobulin synthesis in multiple sclerosis (MS) but the kappa free light chain index (KFLCi) is emerging as an alternative marker, and the combined/sequential uses of IEF and KFLCi have never been challenged. CSF and serum albumin, IgG, kFLC and lFLC were measured by nephelometry; albumin, IgG and kFLC quotients as well as Link and kFLC indexes were calculated; OCBs were evaluated by immunofixation. A total of 150 consecutive patients: 48 with MS, 32 with other neurological inflammatory diseases (NID), 62 with neurological non-inflammatory diseases (NNID), and 8 without any detectable neurological disease (NND) were investigated. Both IEF and KFLCi showed a similar accuracy as diagnostic tests for multiple sclerosis. The high sensitivity and specificity associated with the lower cost of KFLCi suggested to use this test first, followed by IEF as a confirmative procedure. The sequential use of IEF and KFLCi showed high diagnostic efficiency with cost reduction of 43 and 21%, if compared to the contemporary use of both tests, or the unique use of IEF in all patients. The "sequential testing" using KFLCi followed by IEF in MS represents an optimal procedure with accurate performance and lower costs.

  1. Detection of acute lymphoblastic leukemia involvement in pleural fluid in an adult patient with ataxia telangiectasia by flow cytometry method.

    PubMed

    Keklik, Muzaffer; Koker, M Yavuz; Sivgin, Serdar; Camlica, Demet; Pala, Cigdem; Cetin, Mustafa; Kaynar, Leylagul; Unal, Ali; Eser, Bulent

    2014-09-01

    Ataxia-telangiectasia (AT) is a rare multisystem, neurodegenerative genetic disorder. Patients should be closely monitored due to risk of malignancy development. Due to its wide clinical heterogeneity, it often leads physicians to an inaccurate or missed diagnosis, and insight into this rare disease is important. Pediatric patients may develop lymphomas and acute lymphoblastic leukemia (ALL). However, in adults, there are limited numbers of reports regarding association of AT and ALL. Rarely, ALL cases may present with pleural fluid involvement. In our study, we presented an adult case with AT, in which ALL involvement was detected in pleural fluid by flow cytometry (FC). A 20-years old male presented to emergency department with fever, shortness of breath and cough, as he had been followed with a diagnosis of AT. The following findings were detected in laboratory tests: Hb, 11.5 g/L; WBC, 36 × 10(9)/L; Plt: 140 × 10(9)/L. Blastic cells were observed in peripheral blood smear. On chest radiography, pleural fluid appearance was observed. On thorax CT, pleural fluid was detected in both hemithorax. Cytoplasmic CD3(+) and superficial CD3 (+), CD45 (+), CD5 (+), CD7 (+) and CD38 (+) was found in the flow cytometric evaluation of peripheral blood. Superficial CD3 (+), CD2 (+), CD5 (+) and CD7 (+) were found in flow cytometric evaluation of pleural fluid. These findings were considered as consistent with pleural involvement of T-ALL. FC is a potentially useful diagnostic tool for clinical practice and it is a convenience method which has an important role in detection of ALL in patients with pleural fluid.

  2. Treatment of acute kidney injury secondary to oak intoxication with hemodialysis in a miniature zebu.

    PubMed

    Davy-Moyle, Rachel B; Londoño, Leo; Nelson, Elizabeth A; Bandt, Carsten

    2018-06-13

    To describe the successful management of acute kidney injury (AKI) secondary to oak intoxication using hemodialysis in a miniature zebu. A 1-year-old male intact miniature zebu was presented for evaluation of a 2-day history of lethargy, anorexia, decreased urine production, and dry, firm stool. Initial diagnostics revealed severe azotemia and the bull was presumptively diagnosed with AKI secondary to oak intoxication due to free access to oak trees in the pasture. Despite conventional management with IV fluids and supportive therapy, the degree of azotemia progressively worsened, and the bull became oliguric and fluid overloaded. Two treatments with hemodialysis resulted in reduction of azotemia and ketonemia, and resolution of fluid overload and oliguria. The zebu was discharged from the hospital after 10 days of hospitalization. To the authors' knowledge, this is the first reported case using hemodialysis for AKI in a bovid. Treatment with hemodialysis was effective in this case resulting in rapid resolution of azotemia, fluid overload, and oliguria. Hemodialysis may hasten the recovery and decrease morbidity and mortality in bovids with AKI. © Veterinary Emergency and Critical Care Society 2018.

  3. Virtual reality aided visualization of fluid flow simulations with application in medical education and diagnostics.

    PubMed

    Djukic, Tijana; Mandic, Vesna; Filipovic, Nenad

    2013-12-01

    Medical education, training and preoperative diagnostics can be drastically improved with advanced technologies, such as virtual reality. The method proposed in this paper enables medical doctors and students to visualize and manipulate three-dimensional models created from CT or MRI scans, and also to analyze the results of fluid flow simulations. Simulation of fluid flow using the finite element method is performed, in order to compute the shear stress on the artery walls. The simulation of motion through the artery is also enabled. The virtual reality system proposed here could shorten the length of training programs and make the education process more effective. © 2013 Published by Elsevier Ltd.

  4. Evaluation of medical students using the "qi, blood, and fluid" system of Kampo medicine.

    PubMed

    Arai, Makoto; Arai, Katsuhiko; Hioki, Chizuko; Takashi, Masanori; Matsumoto, Kaori; Honda, Masamitsu; Izumi, Shun-ichiro

    2013-04-20

    Although "qi, blood, and fluid" (QBF) is the most important concept for patients in Kampo medicine, there are few studies about the conditions of the QBF system among healthy populations. We used QBF pattern scores to determine whether or not medical students, presumed to be healthy, had any potentially pathological conditions. Six consecutive fourth-year classes totaling 652 medical students evaluated their own QBF conditions using Terasawa's QBF pattern scores. The six conditions: "qi deficiency" (QD), "qi stagnation" (QS), "qi counterflow" (QC), "blood deficiency" (BD), "blood stasis" (BS), and "fluid disturbance" (FD), were categorized according to Terasawa's criteria. The Mann-Whitney U test was used to compare the score differences between the genders, Chi-square test was used to examine gender differences in the QBF diagnoses, and the Spearman's rank-order correlation coefficient analysis was used to analyze the correlation between each category of QBF. In all, 44.6% of the students met at least one diagnostic criterion in the QBF system. QC, BD, BS, and FD were established more in females, and QD and QS were established without gender differences. Most students who were presumed to be healthy were revealed to have some potentially pathological conditions using the QBF system.

  5. Abnormal cerebrospinal fluid biochemistry in biotinidase deficiency causing diagnostic conundrum.

    PubMed

    Krishnakumar, Deepa; Maw, Anna; Brown, Richard; Hogg, Sarah; Calvin, Jackie; Parker, Alasdair P J

    2014-01-01

    Biotinidase deficiency is a treatable cause of infantile epilepsy and the presentation can be nonspecific. The seizures are difficult to differentiate from other causes of epileptic encephalopathy, which generally have a poor prognosis. We report 2 infants who presented with seizures, and whose low cerebrospinal fluid glucose and high cerebrospinal lactate caused a diagnostic dilemma. Subsequent urine organic acids pointed to the correct diagnosis and avoided invasive investigation. The children had a good clinical outcome with resolution of their seizures on biotin treatment.

  6. Fluid and electrolyte disturbances in critically ill patients.

    PubMed

    Lee, Jay Wook

    2010-12-01

    Disturbances in fluid and electrolytes are among the most common clinical problems encountered in the intensive care unit (ICU). Recent studies have reported that fluid and electrolyte imbalances are associated with increased morbidity and mortality among critically ill patients. To provide optimal care, health care providers should be familiar with the principles and practice of fluid and electrolyte physiology and pathophysiology. Fluid resuscitation should be aimed at restoration of normal hemodynamics and tissue perfusion. Early goal-directed therapy has been shown to be effective in patients with severe sepsis or septic shock. On the other hand, liberal fluid administration is associated with adverse outcomes such as prolonged stay in the ICU, higher cost of care, and increased mortality. Development of hyponatremia in critically ill patients is associated with disturbances in the renal mechanism of urinary dilution. Removal of nonosmotic stimuli for vasopressin secretion, judicious use of hypertonic saline, and close monitoring of plasma and urine electrolytes are essential components of therapy. Hypernatremia is associated with cellular dehydration and central nervous system damage. Water deficit should be corrected with hypotonic fluid, and ongoing water loss should be taken into account. Cardiac manifestations should be identified and treated before initiating stepwise diagnostic evaluation of dyskalemias. Divalent ion deficiencies such as hypocalcemia, hypomagnesemia and hypophosphatemia should be identified and corrected, since they are associated with increased adverse events among critically ill patients.

  7. Endoscopic ultrasound-guided transesophageal thoracentesis for minimal pleural effusion.

    PubMed

    Rana, Surinder Singh; Sharma, Ravi; Gupta, Rajesh

    2018-06-19

    Pleural effusion is a common finding both in patients with benign and malignant diseases of pleura and lung with diagnostic thoracentesis establishing the diagnosis in the majority of cases. The diagnostic thoracentesis can be done either blindly or under the guidance of ultrasound or computed tomography. However, minimal pleural effusion is difficult to sample even under image guidance. Endoscopic ultrasound (EUS) is known to detect smaller volume of pleural effusion and, thus, can help in guiding thoracentesis. To analyze the safety and efficacy of EUS-guided diagnostic thoracentesis in patients with undiagnosed minimal pleural effusion retrospectively. Retrospective analysis of the data of patients with minimal pleural effusion, who underwent EUS-guided transesophageal diagnostic thoracentesis over last 2 years, was performed. Thirteen patients (11 male; mean age 46.7 ± 16.2 years) with undiagnosed minimal pleural effusion underwent successful EUS-guided transesophageal diagnostic thoracentesis using a 22-G needle. Seven (53%) patients had fever on presentation whereas two presented with cough and loss of appetite. Eight to 54 mL fluid was aspirated with an attempt to completely empty the pleural cavity. There were no complications of the procedure. EUS-guided diagnostic thoracentesis is a safe and effective alternative for evaluating patients with minimal pleural effusion.

  8. Use of high-frequency ultrasonography for evaluation of skin thickness in relation to hydration status and fluid distribution at various cutaneous sites in dogs.

    PubMed

    Diana, Alessia; Guglielmini, Carlo; Fracassi, Federico; Pietra, Marco; Balletti, Erika; Cipone, Mario

    2008-09-01

    To assess the usefulness of high-frequency diagnostic ultrasonography for evaluation of changes of skin thickness in relation to hydration status and fluid distribution at various cutaneous sites in dogs. 10 clinically normal adult dogs (6 males and 4 females) of various breeds. Ultrasonographic examination of the skin was performed before and after hydration via IV administration of an isotonic crystalloid solution (30 mL/kg/h for 30 minutes). A 13-MHz linear-array transducer was used to obtain series of ultrasonographic images at 4 different cutaneous sites (the frontal, sacral, flank, and metatarsal regions). Weight and various clinicopathologic variables (PCV; serum osmolality; and serum total protein, albumin, and sodium concentrations) were determined before and after the infusion. These variables and ultrasonographic measurements of skin thickness before and after hydration were compared. Among the 10 dogs, mean preinfusion skin thickness ranged from 2,211 microm (metatarsal region) to 3,249 microm (sacral region). Compared with preinfusion values, weight was significantly increased, whereas PCV; serum osmolality; and serum total protein, albumin, and sodium concentrations were significantly decreased after infusion. After infusion, dermal echogenicity decreased and skin thickness increased significantly by 21%, 14%, 15%, and 13% in the frontal, sacral, flank, and metatarsal regions, respectively. Cutaneous site and hydration were correlated with cutaneous characteristics and skin thickness determined by use of high-frequency ultrasonography in dogs. Thus, diagnostic ultrasonography may be a useful tool for the noninvasive evaluation of skin hydration in healthy dogs and in dogs with skin edema.

  9. Diagnostic imaging of small amounts of pleural fluid: pleural effusion vs. physiologic pleural fluid.

    PubMed

    Kocijancic, Igor

    2007-12-01

    The aim of this article is to present an overview of our 10 years clinical research work and early clinical experience with small pleural effusions. Small amounts of pleural fluid are severely difficult to identify with imaging methods (chest x-rays and ultrasound). Nevertheless, it may be an important finding, sometimes leading to a definitive diagnosis of pleural carcinomatosis, infection or other pathologic condition. Chest x-rays were used for many years for the diagnosis of small pleural effusions. Lateral decubitus chest radiographs represented a gold standard for imaging of small amounts of plural fluid for more than 80 years. In the last two decades, ultrasonography of pleural space became a leading real-time method for demonstrating small pleural effusions. Furthermore, the advent of sonographic technology actually enables detection of physiologic pleural fluid in some otherwise healthy individuals. In conclusion, new definitions of the key terms in the field of diagnostic imaging of small amounts of pleural fluid seem to be justified. We suggest that the term pleural fluid should determine physiologic pleural space condition while the term pleural effusion should only be used in the cases of pleural involvement or pleural illness.

  10. Uremic pleuritis: A case report and review of recurrent exudative pleural effusions in children.

    PubMed

    McGraw, Matthew D; Galambos, Csaba; Stillwell, Paul C

    2017-09-01

    Despite similar mechanisms driving pleural fluid accumulation, the causes of pleural effusions in children differ significantly from that of adults. When a pleural effusion re-occurs in an adult, literature recommends early thoracentesis, and consideration for pleuroscopy with biopsy to guide the diagnostic evaluation. In children, there is a paucity of literature for guiding management of recurrent exudative pleural effusion. We present an unusual pediatric case of uremic pleuritis with recurrent pericardial and exudative pleural effusions. © 2017 Wiley Periodicals, Inc.

  11. Contractors Meeting on Combustion Rocket Propulsion Diagnostics of Reacting Flow Held in Monrovia, California on 13-17 June 1988

    DTIC Science & Technology

    1988-06-13

    iern and Aerospace ~imrn University Park, PA 16802 The direct absorption of cncz-trated solar radiation in a flowing gas has potential utility in a...nmber of I ajplicatiau. 7e present research is concerned with evaluating the feasibility of direct absorpticin for solar therml pvcpIlsin. The primary...hallene in solar propulsion lies in firding a caibdate working fluid that can absorb a significant fraction of the irnoing enrgy in a reasonable length

  12. Serum and peritoneal fluid concentrations of soluble human leukocyte antigen, tumor necrosis factor alpha and interleukin 10 in patients with selected ovarian pathologies.

    PubMed

    Sipak-Szmigiel, Olimpia; Włodarski, Piotr; Ronin-Walknowska, Elżbieta; Niedzielski, Andrzej; Karakiewicz, Beata; Słuczanowska-Głąbowska, Sylwia; Laszczyńska, Maria; Malinowski, Witold

    2017-04-04

    Although immune system plays a key role in the pathogenesis of both endometriosis and ovarian cancer, its function is different. Therefore, we hypothesized, that selected immune parameters can serve as diagnostic markers of these two conditions. The aim of this study was to compare serum and peritoneal fluid concentrations of sHLA-G, IL-10 and TNF-alpha in women with selected ovarian pathologies: benign serous cysts, endometrioma and malignant tumors. Clinical significance of using them for diagnostic purposes in women with serous ovarian cysts, endometriosis, and ovarian cancer, which in the future may improve the early diagnosis of ovarian diseases. The study included women treated surgically for benign serous ovarian cysts, ovarian endometrioma and serous ovarian adenocarcinomas. Peripheral blood and peritoneal fluid samples were obtained intraoperatively. Patients with benign serous cysts, endometrioma and ovarian malignancies did not differ significantly in terms of their serum and peritoneal fluid concentrations of sHLA-G. Ovarian cancer patients presented with significantly higher median serum concentrations of IL-10 and TNF-alpha than other study subjects. Median concentrations of IL-10 and TNF-alpha in peritoneal fluid turned out to be the highest in ovarian cancer patients, followed by women with endometrioma and subjects with benign serous cysts. All these intergroup differences were statistically significant. Irrespective of the group, median concentrations of sHLA-G, IL-10 and TNF-alpha in peritoneal fluid were higher than serum levels of these markers. Elevated serum and peritoneal fluid concentrations of IL-10 and TNF-alpha distinguish ovarian malignancies and endometriomas from benign serous ovarian cysts. In contrast to endometriosis, ovarian malignancies are characterized by elevated peritoneal fluid concentrations of IL-10 and TNF-alpha, elevated serum concentrations of IL-10 and low serum levels of TNF-alpha. Serum and peritoneal fluid concentrations of sHLA-G have no diagnostic value in differentiating between ovarian malignancies and endometriomas.

  13. Molecular diagnosis of microbial aetiologies using SepsiTest™ in the daily routine of a diagnostic laboratory.

    PubMed

    Haag, Heike; Locher, Franziska; Nolte, Oliver

    2013-08-01

    A universal PCR and sequencing test, SepsiTest™ (Molzym, Germany) was evaluated for its applicability during daily diagnostic routine in a privately operated laboratory. In total, 96 specimens originating from 66 patients under suspect of infectious endocarditis, infections of joints, encephalitis/meningitis, systemic infections and infections of unknown genesis were PCR analysed and compared to culture results. Samples comprised cultured and non-cultured blood, synovial fluid, synovial tissue, heart valves, pacemakers, spinal tissue, cerebrospinal fluid, and swabs. PCR and culture were concordant in 26 negative and 8 positive cases (51.5%). A group of 25 patients was culture-negative but PCR-positive (37.9%). In at least 14 of these, common and/or rare aetiologies were identified, while for 4 patients the results of 16S PCR could not be unequivocally linked with the underlying disease. Benefits and limitations of the molecular test are discussed with special emphasis on technical and economic issues. In conclusion, SepsiTest™ proved to be a valuable tool for the diagnosis of aetiologies, particularly in cases of culture-negative patients who are under strong suspicion for an infection. Copyright © 2013 Elsevier Inc. All rights reserved.

  14. Diagnostic imaging in uterine incisional necrosis/dehiscence complicating cesarean section.

    PubMed

    Rivlin, Michel E; Patel, Rameshkumar B; Carroll, C Shannon; Morrison, John C

    2005-12-01

    To review the diagnostic imaging studies in patients with surgically proven uterine incisional necrosis/dehiscence complicating cesarean section and to compare these studies with the findings at surgery. Over a 6-year period, the records of 7 patients with imaging studies prior to surgery for uterine incisional necrosis/dehiscence complicating cesarean delivery were reviewed and compared with the findings at surgery. Four cases underwent computed tomography (CT) and sonography, 1 underwent CT only, and 2 underwent sonography only. Abnormal findings included abdominal free fluid in 4, pleural effusions in 3, dilated bowel in 3, possible bladder flap hematoma in 2 and single instances of liver abscess and retained products of conception. In no cases were all the studies normal, and necrosis/dehiscence was not demonstrated in any patient. Abdominal free fluid, bowel distension, pleural effusion and bladder flap hematoma seen on CT or sonogram in the postcesarean context suggest the possibility of uterine incisional necrosis/dehiscence. Magnetic resonance imaging (MRI) might then be indicated since MRI may be superior to CT in evaluating complications at the incisional site because of its multiplanar capability and greater degree of soft tissue contrast.

  15. High-Temperature Lubricant Analyses Using the System for Thermal Diagnostic Studies (STDS). A Feasibility Study

    DTIC Science & Technology

    1990-07-01

    permeation chromatography (GPC) have been applied to lubricant type samples. 8 Most recently the newly introduced supercritical fluid chromatography (SFC... fluids , such as lubricants and hydraulic fluids can also be examined using various inverse chromatography procedures. Another mode, known as reaction...introduction of new gaseous extraction techniques, e.g., supercritical fluid extraction, procedures such as IGC will probably be developed for vastly

  16. Preoperative easily misdiagnosed telangiectatic osteosarcoma: clinical-radiologic-pathologic correlations.

    PubMed

    Gao, Zhen-Hua; Yin, Jun-Qiang; Liu, Da-Wei; Meng, Quan-Fei; Li, Jia-Ping

    2013-12-11

    To describe the clinical, imaging, and pathologic characteristics and diagnostic methods of telangiectatic osteosarcoma (TOS) for improving the diagnostic level. The authors retrospectively reviewed patient demographics, serum alkaline phosphatase (AKP) levels, preoperative biopsy pathologic reports, pathologic materials, imaging findings, and treatment outcomes from 26 patients with TOS. Patient images from radiography (26 cases) and magnetic resonance (MR) imaging (22 cases) were evaluated by 3 authors in consensus for intrinsic characteristics. There were 15 male and 11 female patients in the study, with an age of 9-32 years (mean age 15.9 years). Eighteen of 26 patients died of lung metastases within 5 years of follow-up. The distal femur was affected more commonly (14 cases, 53.8%). Regarding serum AKP, normal (8 cases) or mildly elevated (18 cases) levels were found before preoperative chemotherapy. Radiographs showed geographic bone lysis without sclerotic margin (26 cases), cortical destruction (26 cases), periosteal new bone formation (24 cases), soft-tissue mass (23 cases), and matrix mineralization (4 cases). The aggressive radiographic features of TOS simulated the appearance of conventional high-grade intramedullary osteosarcoma, though different from aneurysmal bone cyst. MR images demonstrated multiple big (16 cases) or small (6 cases) cystic spaces, fluid-fluid levels (14 cases), soft-tissue mass (22 cases), and thick peripheral and septal enhancement (22 cases). Nine of 26 cases were misdiagnosed as aneurysmal bone cysts by preoperative core-needle biopsy, owing to the absence of viable high-grade sarcomatous cells in the small tissue samples. The aggressive growth pattern with occasional matrix mineralization, and multiple big or small fluid-filled cavities with thick peripheral, septal, and nodular tissue surrounding the fluid-filled cavities are characteristic imaging features of TOS, and these features are helpful in making the correct preoperative diagnosis of TOS.

  17. Mueller-matrix of laser-induced autofluorescence of polycrystalline films of dried peritoneal fluid in diagnostics of endometriosis

    NASA Astrophysics Data System (ADS)

    Ushenko, Yuriy A.; Koval, Galina D.; Ushenko, Alexander G.; Dubolazov, Olexander V.; Ushenko, Vladimir A.; Novakovskaia, Olga Yu.

    2016-07-01

    This research presents investigation results of the diagnostic efficiency of an azimuthally stable Mueller-matrix method of analysis of laser autofluorescence of polycrystalline films of dried uterine cavity peritoneal fluid. A model of the generalized optical anisotropy of films of dried peritoneal fluid is proposed in order to define the processes of laser autofluorescence. The influence of complex mechanisms of both phase (linear and circular birefringence) and amplitude (linear and circular dichroism) anisotropies is taken into consideration. The interconnections between the azimuthally stable Mueller-matrix elements characterizing laser autofluorescence and different mechanisms of optical anisotropy are determined. The statistical analysis of coordinate distributions of such Mueller-matrix rotation invariants is proposed. Thereupon the quantitative criteria (statistic moments of the first to the fourth order) of differentiation of polycrystalline films of dried peritoneal fluid, group 1 (healthy donors) and group 2 (uterus endometriosis patients), are determined.

  18. Evaluation of Cepheid's Xpert MTB/RIF Test on Pleural Fluid in the Diagnosis of Pleural Tuberculosis in a High Prevalence HIV/TB Setting

    PubMed Central

    Kirenga, Bruce J.; Kiragga, Agnes; Lukande, Robert; Nsereko, Maria; Ssengooba, Willy; Katamba, Achilles; Worodria, William; Joloba, Moses L.; Mayanja-Kizza, Harriet

    2014-01-01

    Background Diagnosis of pleural tuberculosis (TB) using routinely available diagnostic methods is challenging due to the paucibacillary nature of the disease. Histopathology and pleural tissue TB culture involves an invasive procedure which requires expertise and appropriate equipment, both often unavailable in many health units. Xpert MTB/Rif test has been widely evaluated in sputum specimens but data on its performance in pleural TB is scarce. We evaluated the accuracy of Cepheid's Xpert MTB/Rif test on pleural fluid in the diagnosis of pleural TB in Uganda. Methods Consenting adult patients with exudative pleural effusions underwent pleural biopsy and the tissue obtained subjected to Lowenstein-Jensen and mycobacterial growth indicator tube MTB cultures and histopathology. Pleural fluid for Xpert MTB/Rif testing was also collected. Data on socio-demographic characteristics, clinical symptoms, HIV status and CD4 count were also collected. Sensitivity, specificity, positive and negative predictive values of Xpert MTB/Rif test on pleural fluid in pleural TB diagnosis were calculated using pleural tissue MTB culture and/or histopathology as the reference standard. Results Of the 116 participants [female 50%, mean age 34 (SD ±13], 87/116 (75%) had pleural TB confirmed on pleural tissue culture and/or histopathology. The Xpert MTB/Rif test identified 25 (28.7%) of the 87 confirmed pleural TB cases. The sensitivity and specificity of Xpert MTB/Rif test were 28.7% and 96.6% respectively while the positive and negative predictive values were 96.1% and 31.1% respectively. Conclusion Xpert MTB/Rif test on pleural fluid does not accurately diagnose pleural TB and therefore cannot be used as an initial evaluation test in patients with suspected pleural TB. New, rapid and accurate tests for the diagnosis of pleural TB are still warranted. PMID:25051491

  19. Etiology and microbial patterns of pulmonary infiltrates in patients with orthotopic liver transplantation.

    PubMed

    Torres, A; Ewig, S; Insausti, J; Guergué, J M; Xaubet, A; Mas, A; Salmeron, J M

    2000-02-01

    To evaluate the etiology and microbial patterns of pulmonary infiltrates in liver transplant patients using a bronchoscopic diagnostic approach and the impact of diagnostic results on antimicrobial treatment decisions. A prospective cohort study. A 1,000-bed tertiary-care university hospital. Fifty consecutive liver transplant patients with 60 episodes of pulmonary infiltrates (33 episodes during mechanical ventilation) were studied using flexible bronchoscopy with protected specimen brush (PSB) and BAL. A definite infectious etiology was confirmed in 29 episodes (48%). Eighteen episodes corresponded to probable pneumonia (30%), 10 episodes had noninfectious etiologies (17%), and 3 remained undetermined (5%). Opportunistic infections were the most frequent etiology (16/29, 55%, including 1 mixed etiology). Bacterial infections (mainly Gram-negative) accounted for 14 of 29 episodes (48%), including 1 of mixed etiology. The majority of bacterial pneumonia episodes (n = 10, 71%) occurred in period 1 (1 to 28 days posttransplant) during mechanical ventilation, whereas opportunistic episodes were predominant in periods 2 and 3 (29 to 180 days and > 180 days posttransplant, respectively; n = 14, 82%). Microbial treatment was changed according to diagnostic results in 21 episodes (35%). Microbial patterns in liver transplant patients with pulmonary infiltrates corresponded to nosocomial, mainly Gram-negative bacterial pneumonia in period 1, and to opportunistic infections in period 2 and, to a lesser extent, period 3. A comprehensive diagnostic evaluation including PSB and BAL fluid examination frequently guided specific antimicrobial therapy.

  20. Pulse-encoded ultrasound imaging of the vitreous with an annular array.

    PubMed

    Silverman, Ronald H; Ketterling, Jeffrey A; Mamou, Jonathan; Lloyd, Harriet O; Filoux, Erwan; Coleman, D Jackson

    2012-01-01

    The vitreous body is nearly transparent both optically and ultrasonically. Conventional 10- to 12-MHz diagnostic ultrasound can detect vitreous inhomogeneities at high gain settings, but has limited resolution and sensitivity, especially outside the fixed focal zone near the retina. To improve visualization of faint intravitreal fluid/gel interfaces, the authors fabricated a spherically curved 20-MHz five-element annular array ultrasound transducer, implemented a synthetic-focusing algorithm to extend the depth-of-field, and used a pulse-encoding strategy to increase sensitivity. The authors evaluated a human subject with a recent posterior vitreous detachment and compared the annular array with conventional 10-MHz ultrasound and spectral-domain optical coherence tomography. With synthetic focusing and chirp pulse-encoding, the array allowed visualization of the formed and fluid components of the vitreous with improved sensitivity and resolution compared with the conventional B-scan. Although optical coherence tomography allowed assessment of the posterior vitreoretinal interface, the ultrasound array allowed evaluation of the entire vitreous body. Copyright 2012, SLACK Incorporated.

  1. Development and Capabilities of ISS Flow Boiling and Condensation Experiment

    NASA Technical Reports Server (NTRS)

    Nahra, Henry; Hasan, Mohammad; Balasubramaniam, R.; Patania, Michelle; Hall, Nancy; Wagner, James; Mackey, Jeffrey; Frankenfield, Bruce; Hauser, Daniel; Harpster, George; hide

    2015-01-01

    An experimental facility to perform flow boiling and condensation experiments in long duration microgravity environment is being designed for operation on the International Space Station (ISS). This work describes the design of the subsystems of the FBCE including the Fluid subsystem modules, data acquisition, controls, and diagnostics. Subsystems and components are designed within the constraints of the ISS Fluid Integrated Rack in terms of power availability, cooling capability, mass and volume, and most importantly the safety requirements. In this work we present the results of ground-based performance testing of the FBCE subsystem modules and test module which consist of the two condensation modules and the flow boiling module. During this testing, we evaluated the pressure drop profile across different components of the fluid subsystem, heater performance, on-orbit degassing subsystem, heat loss from different modules and components, and performance of the test modules. These results will be used in the refinement of the flight system design and build-up of the FBCE which is manifested for flight in late 2017-early 2018.

  2. Volumetric velocimetry for fluid flows

    NASA Astrophysics Data System (ADS)

    Discetti, Stefano; Coletti, Filippo

    2018-04-01

    In recent years, several techniques have been introduced that are capable of extracting 3D three-component velocity fields in fluid flows. Fast-paced developments in both hardware and processing algorithms have generated a diverse set of methods, with a growing range of applications in flow diagnostics. This has been further enriched by the increasingly marked trend of hybridization, in which the differences between techniques are fading. In this review, we carry out a survey of the prominent methods, including optical techniques and approaches based on medical imaging. An overview of each is given with an example of an application from the literature, while focusing on their respective strengths and challenges. A framework for the evaluation of velocimetry performance in terms of dynamic spatial range is discussed, along with technological trends and emerging strategies to exploit 3D data. While critical challenges still exist, these observations highlight how volumetric techniques are transforming experimental fluid mechanics, and that the possibilities they offer have just begun to be explored.

  3. Amniotic fluid digestive enzyme analysis is useful for identifying CFTR gene mutations of unclear significance.

    PubMed

    Oca, Florine; Dreux, Sophie; Gérard, Bénédicte; Simon-Bouy, Brigitte; de Becdelièvre, Alix; Ferec, Claude; Girodon, Emmanuelle; Muller, Françoise

    2009-12-01

    The large number of CFTR [cystic fibrosis transmembrane conductance regulator (ATP-binding cassette sub-family C, member 7)] mutations and the existence of variants of unclear significance complicate the prenatal diagnosis of cystic fibrosis (CF). The aim of this study was to determine whether the pattern of amniotic fluid digestive enzymes (AF-DEs) could be correlated with the severity of CFTR mutations. The AF-DE pattern (gamma-glutamyltranspeptidase, aminopeptidase M, and the intestinal isoform of alkaline phosphatase) was retrospectively analyzed in 43 AF samples. All fetuses presented 2 CFTR mutations, which were classified according to the severity of the disease: CF/CF (n = 38); CF/CFTR-related disorders (n = 1); and CF/unknown variant (n = 4). The relationships between clinical CF status, CFTR mutations, and AF-DE pattern were studied. Of 38 severely affected CF fetuses, an "obstructive" AF-DE pattern was observed in 15 of 15 samples collected before 22 weeks, irrespective of the CFTR mutation (diagnostic sensitivity, 100%; diagnostic specificity, 99.8%). In the 23 fetuses evaluated after 22 weeks, the AF-DE pattern was abnormal in 7 cases and noncontributive in 16 (diagnostic sensitivity, 30.4%; diagnostic specificity, 99.8%). Of the 5 questionable cases (F508del/N1224K, F508del/L73F, 3849+10kbC>T/G1127E, F508del/S1235R, F508del/G622D), all were CF symptom free at 2-4 years of follow-up. The AF-DE pattern (<22 weeks) was typical in 3 cases but abnormal in the last 2 cases. AF-DE analysis is of value for prenatal CF diagnosis in classic forms of CF and could be helpful in nonclassic CF.

  4. Diagnostic utility of the cell block method versus the conventional smear study in pleural fluid cytology

    PubMed Central

    Shivakumarswamy, Udasimath; Arakeri, Surekha U; Karigowdar, Mahesh H; Yelikar, BR

    2012-01-01

    Background: The cytological examinations of serous effusions have been well-accepted, and a positive diagnosis is often considered as a definitive diagnosis. It helps in staging, prognosis and management of the patients in malignancies and also gives information about various inflammatory and non-inflammatory lesions. Diagnostic problems arise in everyday practice to differentiate reactive atypical mesothelial cells and malignant cells by the routine conventional smear (CS) method. Aims: To compare the morphological features of the CS method with those of the cell block (CB) method and also to assess the utility and sensitivity of the CB method in the cytodiagnosis of pleural effusions. Materials and Methods: The study was conducted in the cytology section of the Department of Pathology. Sixty pleural fluid samples were subjected to diagnostic evaluation for over a period of 20 months. Along with the conventional smears, cell blocks were prepared by using 10% alcohol–formalin as a fixative agent. Statistical analysis with the ‘z test’ was performed to identify the cellularity, using the CS and CB methods. Mc. Naemer's χ2test was used to identify the additional yield for malignancy by the CB method. Results: Cellularity and additional yield for malignancy was 15% more by the CB method. Conclusions: The CB method provides high cellularity, better architectural patterns, morphological features and an additional yield of malignant cells, and thereby, increases the sensitivity of the cytodiagnosis when compared with the CS method. PMID:22438610

  5. Ultrasonographic evaluation of abdominal distension in 52 camels (Camelus dromedarius).

    PubMed

    Tharwat, Mohamed; Al-Sobayil, Fahd; Ali, Ahmed; Buczinski, Sébastien

    2012-08-01

    The purpose of this study was to assess the diagnostic value of ultrasonography in the evaluation of abdominal distension in 52 camels (Camelus dromedarius). The conditions included trypanosomiasis (n=35), intestinal obstruction (n=12) and ruptured urinary bladder (n=5). Fifteen clinically normal camels were included as controls. Transabdominal and transrectal ultrasonography was carried out on all camels. In animals with trypanosomiasis, ultrasonographic findings included accumulation of massive amounts of hypoechoic abdominal fluids where liver, intestine, kidney, spleen and urinary bladder were imaged floating. Except in two cases of bile duct calcification and one of hepatic abscessation, no detectable abnormal sonographic lesions were detected while imaging the hepatic and renal parenchyma, and the heart and its valves and major blood vessels. In camels with intestinal obstruction, ultrasonographic findings included distended intestinal loops with markedly reduced or absent motility. In one camel, the intestinal lumen contained localised hyperechoic material that was consistent with a foreign body. Hypoechoic fluid with or without fibrin was seen between intestinal loops. In camels with ruptured urinary bladder, ultrasonographic findings included collapsed and perforated bladder, echogenic blood clots within the urinary bladder and peritoneal cavity, increased thickness of the bladder wall, floating intestines in hypoechogenic fluid and echogenic calculi within the urethra. Ultrasonography was considered a useful tool for the evaluation of dromedary camels with abdominal distension. Copyright © 2011 Elsevier Ltd. All rights reserved.

  6. Helminth parasitic infections of the central nervous system: a diagnostic approach.

    PubMed

    Othman, Ahmad A; Bruschi, Fabrizio; Ganna, Ahmed A

    2014-04-01

    Helminth parasitic infections of the central nervous system (CNS) occur worldwide with high prevalence in tropical and subtropical countries. Clinical evaluation of patients is mandatory, and it is convenient to group the clinical manifestations into syndromes: for example space-occupying lesions, meningitis, and encephalitis. The history should focus on residence or travel to endemic areas, diet, activities, intercurrent medical conditions, and associated clinical clues. Direct parasitological diagnosis can be reached by cerebrospinal fluid and cerebral tissue examination either by microscopy, culture, or immunological techniques. Immunodiagnosis by detection of parasite antibodies or antigens in serum could provide indirect evidence of parasitic infections. In addition, various imaging and radiological techniques e.g., computed tomography (CT) scan and magnetic resonance imaging (MRI) complement the diagnostic work-up of CNS diseases. Finally, the helminthic CNS infections of global impact, such as schistosomiasis, neurotoxocariasis, Strongyloides infection, neurotrichinosis, neurocysticercosis, and echinococcosis will be briefly discussed as regards the principal clinical and diagnostic features.

  7. Performance Evaluation of an Automated ELISA System for Alzheimer's Disease Detection in Clinical Routine.

    PubMed

    Chiasserini, Davide; Biscetti, Leonardo; Farotti, Lucia; Eusebi, Paolo; Salvadori, Nicola; Lisetti, Viviana; Baschieri, Francesca; Chipi, Elena; Frattini, Giulia; Stoops, Erik; Vanderstichele, Hugo; Calabresi, Paolo; Parnetti, Lucilla

    2016-07-22

    The variability of Alzheimer's disease (AD) cerebrospinal fluid (CSF) biomarkers undermines their full-fledged introduction into routine diagnostics and clinical trials. Automation may help to increase precision and decrease operator errors, eventually improving the diagnostic performance. Here we evaluated three new CSF immunoassays, EUROIMMUNtrademark amyloid-β 1-40 (Aβ1-40), amyloid-β 1-42 (Aβ1-42), and total tau (t-tau), in combination with automated analysis of the samples. The CSF biomarkers were measured in a cohort consisting of AD patients (n = 28), mild cognitive impairment (MCI, n = 77), and neurological controls (OND, n = 35). MCI patients were evaluated yearly and cognitive functions were assessed by Mini-Mental State Examination. The patients clinically diagnosed with AD and MCI were classified according to the CSF biomarkers profile following NIA-AA criteria and the Erlangen score. Technical evaluation of the immunoassays was performed together with the calculation of their diagnostic performance. Furthermore, the results for EUROIMMUN Aβ1-42 and t-tau were compared to standard immunoassay methods (INNOTESTtrademark). EUROIMMUN assays for Aβ1-42 and t-tau correlated with INNOTEST (r = 0.83, p < 0.001 for both) and allowed a similar interpretation of the CSF profiles. The Aβ1-42/Aβ1-40 ratio measured with EUROIMMUN was the best parameter for AD detection and improved the diagnostic accuracy of Aβ1-42 (area under the curve = 0.93). In MCI patients, the Aβ1-42/Aβ1-40 ratio was associated with cognitive decline and clinical progression to AD.The diagnostic performance of the EUROIMMUN assays with automation is comparable to other currently used methods. The variability of the method and the value of the Aβ1-42/Aβ1-40 ratio in AD diagnosis need to be validated in large multi-center studies.

  8. Napsin A levels in epithelial lining fluid as a diagnostic biomarker of primary lung adenocarcinoma.

    PubMed

    Uchida, Akifumi; Samukawa, Takuya; Kumamoto, Tomohiro; Ohshige, Masahiro; Hatanaka, Kazuhito; Nakamura, Yoshihiro; Mizuno, Keiko; Higashimoto, Ikkou; Sato, Masami; Inoue, Hiromasa

    2017-12-12

    It is crucial to develop novel diagnostic approaches for determining if peripheral lung nodules are malignant, as such nodules are frequently detected due to the increased use of chest computed tomography scans. To this end, we evaluated levels of napsin A in epithelial lining fluid (ELF), since napsin A has been reported to be an immunohistochemical biomarker for histological diagnosis of primary lung adenocarcinoma. In consecutive patients with indeterminate peripheral lung nodules, ELF samples were obtained using a bronchoscopic microsampling (BMS) technique. The levels of napsin A and carcinoembryonic antigen (CEA) in ELF at the nodule site were compared with those at the contralateral site. A final diagnosis of primary lung adenocarcinoma was established by surgical resection. We performed BMS in 43 consecutive patients. Among patients with primary lung adenocarcinoma, the napsin A levels in ELF at the nodule site were markedly higher than those at the contralateral site, while there were no significant differences in CEA levels. Furthermore, in 18 patients who were undiagnosed by bronchoscopy and finally diagnosed by surgery, the napsin A levels in ELF at the nodule site were identically significantly higher than those at the contralateral site. In patients with non-adenocarcinoma, there were no differences in napsin A levels in ELF. The area under the receiver operator characteristic curve for identifying primary lung adenocarcinoma was 0.840 for napsin A and 0.542 for CEA. Evaluation of napsin A levels in ELF may be useful for distinguishing primary lung adenocarcinoma.

  9. Current Approaches and Clinician Attitudes to the Use of Cerebrospinal Fluid Biomarkers in Diagnostic Evaluation of Dementia in Europe.

    PubMed

    Miller, Anne-Marie; Balasa, Mircea; Blennow, Kaj; Gardiner, Mary; Rutkowska, Aleksandra; Scheltens, Philip; Teunissen, Charlotte E; Visser, Pieter Jelle; Winblad, Bengt; Waldemar, Gunhild; Lawlor, Brian

    2017-01-01

    BIOMARKAPD seeks to diminish the barriers associated with the clinical use of cerebrospinal fluid (CSF) biomarker analysis by reducing variation in CSF laboratory methodologies and generating consensus recommendations on their clinical interpretation and application for dementia diagnosis. To examine the disparity in practitioner attitudes and clinical practice relating to the use of CSF biomarkers for dementia diagnosis across Europe. Clinical dementia experts were surveyed on the prevalence of national consensus guidelines and analytical reimbursement across Europe, their biomarker platform preferences, lumbar puncture methodologies and application of reference values and cut-offs for CSF analysis. 74% of respondents (total n = 51) use CSF biomarkers in clinical practice and 69% perform lumbar punctures on an outpatient basis. Most use CSF biomarkers to diagnose atypical (84%) and early-onset cases of cognitive impairment (71%) and for the differential diagnosis of other dementias (69%). 82% state they are sufficiently informed about CSF biomarkers yet 61% report a lack of national consensus guidelines on their use for dementia diagnosis. 48% of countries represented do not reimburse clinical CSF analysis costs. 43% report using normal reference ranges derived from publications. Variations in attitude and practice relating to CSF biomarkers, widely recognised as barriers to their clinical acceptance, remain evident within and between countries across Europe, even in expert centres. These shortcomings must be addressed by developing consensus guidelines on CSF-related methodologies and their clinical application, to further their use for the diagnostic evaluation of dementia.

  10. Development and evaluation of a culture-free microbiota profiling platform (MYcrobiota) for clinical diagnostics.

    PubMed

    Boers, Stefan A; Hiltemann, Saskia D; Stubbs, Andrew P; Jansen, Ruud; Hays, John P

    2018-06-01

    Microbiota profiling has the potential to greatly impact on routine clinical diagnostics by detecting DNA derived from live, fastidious, and dead bacterial cells present within clinical samples. Such results could potentially be used to benefit patients by influencing antibiotic prescribing practices or to generate new classical-based diagnostic methods, e.g., culture or PCR. However, technical flaws in 16S rRNA gene next-generation sequencing (NGS) protocols, together with the requirement for access to bioinformatics, currently hinder the introduction of microbiota analysis into clinical diagnostics. Here, we report on the development and evaluation of an "end-to-end" microbiota profiling platform (MYcrobiota), which combines our previously validated micelle PCR/NGS (micPCR/NGS) methodology with an easy-to-use, dedicated bioinformatics pipeline. The newly designed bioinformatics pipeline processes micPCR/NGS data automatically and summarizes the results in interactive, but simple web reports. In order to explore the utility of MYcrobiota in clinical diagnostics, 47 clinical samples (40 "damaged skin" samples and 7 synovial fluids) were investigated using routine bacterial culture as comparator. MYcrobiota confirmed the presence of bacterial DNA in 37/37 culture-positive samples and detected bacterial taxa in 2/10 culture-negative samples. Moreover, 36/38 potentially relevant aerobic bacterial taxa and 3/3 mixtures of anaerobic bacteria were identified using culture and MYcrobiota, with the sensitivity and specificity being 95%. Interestingly, the majority of the 448 bacterial taxa identified using MYcrobiota were not identified using culture, which could potentially have an impact on clinical decision-making. Taken together, the development of MYcrobiota is a promising step towards the introduction of microbiota analysis into clinical diagnostic laboratories.

  11. Evaluation of haemoglobin in blister fluid as an indicator of paediatric burn wound depth.

    PubMed

    Tanzer, Catherine; Sampson, Dayle L; Broadbent, James A; Cuttle, Leila; Kempf, Margit; Kimble, Roy M; Upton, Zee; Parker, Tony J

    2015-08-01

    The early and accurate assessment of burns is essential to inform patient treatment regimens; however, this first critical step in clinical practice remains a challenge for specialist burns clinicians worldwide. In this regard, protein biomarkers are a potential adjunct diagnostic tool to assist experienced clinical judgement. Free circulating haemoglobin has previously shown some promise as an indicator of burn depth in a murine animal model. Using blister fluid collected from paediatric burn patients, haemoglobin abundance was measured using semi-quantitative Western blot and immunoassays. Although a trend was observed in which haemoglobin abundance increased with burn wound severity, several patient samples deviated significantly from this trend. Further, it was found that haemoglobin concentration decreased significantly when whole cells, cell debris and fibrinous matrix was removed from the blister fluid by centrifugation; although the relationship to depth was still present. Statistical analyses showed that haemoglobin abundance in the fluid was more strongly related to the time between injury and sample collection and the time taken for spontaneous re-epithelialisation. We hypothesise that prolonged exposure to the blister fluid microenvironment may result in an increased haemoglobin abundance due to erythrocyte lysis, and delayed wound healing. Copyright © 2015 Elsevier Ltd and ISBI. All rights reserved.

  12. Tumor necrosis factor α level in cerebrospinal fluid for bacterial and aseptic meningitis: a diagnostic meta-analysis.

    PubMed

    Lv, S; Zhao, J; Zhang, J; Kwon, S; Han, M; Bian, R; Fu, H; Zhang, Y; Pan, H

    2014-08-01

    In our previous study, tumor necrosis factor α (TNF-α) was identified as an effective target for sepsis patients (Int J Clin Pract, 68, 2014, 520). TNF-α in cerebrospinal fluid (CSF) was also investigated for its utility in the differential diagnosis of bacterial and aseptic meningitis. However, there has been neither definite nor convincing evidence so far. Here the overall diagnostic accuracy of TNF-α in differentiation between bacterial and aseptic meningitis was evaluated through the meta-analysis of diagnostic tests. The sensitivity, specificity and other measures of accuracy were pooled using random effect models. Summary receiver operating characteristic curves were used to assess overall test performance. Publication bias was evaluated using funnel plots, and sensitivity analysis was also introduced. A total of 21 studies involving bacterial meningitis (678) and aseptic meningitis (694) involved a total of 1372 patients. The pooled sensitivity and specificity for the TNF-α test were 0.83 [95% confidence interval (CI) 0.80-0.86, I(2)  = 65.1] and 0.92 (95% CI 0.89-0.94, I(2)  = 61.8), respectively. The positive likelihood ratio was 12.05 (95% CI 7.41-19.60, I(2)  = 36.5), the negative likelihood ratio was 0.17 (95% CI 0.13-0.24, I(2)  = 59.4), and TNF-α was significantly associated with bacterial meningitis, with a diagnostic odds ratio of 49.84 (95% CI 28.53-87.06, I(2)  = 47.9). The overall accuracy of the TNF-α test was very high with the area under the curve 0.9317. Publication bias was absent, and sensitivity analysis suggested that our results were highly stable. Our meta-analysis suggested that TNF-α could be recommended as a useful marker for diagnosis of bacterial meningitis and differential diagnosis between bacterial and aseptic meningitis with high sensitivity and specificity. Thus, hospitals should be encouraged to conduct TNF-α tests in CSF after lumbar puncture. © 2014 The Author(s) European Journal of Neurology © 2014 EAN.

  13. False-negative rate of gram-stain microscopy for diagnosis of septic arthritis: suggestions for improvement.

    PubMed

    Stirling, Paul; Faroug, Radwane; Amanat, Suheil; Ahmed, Abdulkhaled; Armstrong, Malcolm; Sharma, Pankaj; Qamruddin, Ahmed

    2014-01-01

    We quantify the false-negative diagnostic rate of septic arthritis using Gram-stain microscopy of synovial fluid and compare this to values reported in the peer-reviewed literature. We propose a method of improving the diagnostic value of Gram-stain microscopy using Lithium Heparin containers that prevent synovial fluid coagulation. Retrospective study of the Manchester Royal Infirmary microbiology database of patients undergoing synovial fluid Gram-stain and culture between December 2003 and March 2012 was undertaken. The initial cohort of 1896 synovial fluid analyses for suspected septic arthritis was reduced to 143 after exclusion criteria were applied. Analysis of our Gram-stain microscopy yielded 111 false-negative results from a cohort size of 143 positive synovial fluid cultures, giving a false-negative rate of 78%. We report a false-negative rate of Gram-stain microscopy for septic arthritis of 78%. Clinicians should therefore avoid the investigation until a statistically significant data set confirms its efficacy. The investigation's value could be improved by using Lithium Heparin containers to collect homogenous synovial fluid samples. Ongoing research aims to establish how much this could reduce the false-negative rate.

  14. Diagnostic Accuracy of Natriuretic Peptides for Heart Failure in Patients with Pleural Effusion: A Systematic Review and Updated Meta-Analysis

    PubMed Central

    Cheng, Juan-Juan; Zhao, Shi-Di; Gao, Ming-Zhu; Huang, Hong-Yu; Gu, Bing; Ma, Ping; Chen, Yan; Wang, Jun-Hong; Yang, Cheng-Jian; Yan, Zi-He

    2015-01-01

    Background Previous studies have reported that natriuretic peptides in the blood and pleural fluid (PF) are effective diagnostic markers for heart failure (HF). These natriuretic peptides include N-terminal pro-brain natriuretic peptide (NT-proBNP), brain natriuretic peptide (BNP), and midregion pro-atrial natriuretic peptide (MR-proANP). This systematic review and meta-analysis evaluates the diagnostic accuracy of blood and PF natriuretic peptides for HF in patients with pleural effusion. Methods PubMed and EMBASE databases were searched to identify articles published in English that investigated the diagnostic accuracy of BNP, NT-proBNP, and MR-proANP for HF. The last search was performed on 9 October 2014. The quality of the eligible studies was assessed using the revised Quality Assessment of Diagnostic Accuracy Studies tool. The diagnostic performance characteristics (sensitivity, specificity, and other measures of accuracy) were pooled and examined using a bivariate model. Results In total, 14 studies were included in the meta-analysis, including 12 studies reporting the diagnostic accuracy of PF NT-proBNP and 4 studies evaluating blood NT-proBNP. The summary estimates of PF NT-proBNP for HF had a diagnostic sensitivity of 0.94 (95% confidence interval [CI]: 0.90–0.96), specificity of 0.91 (95% CI: 0.86–0.95), positive likelihood ratio of 10.9 (95% CI: 6.4–18.6), negative likelihood ratio of 0.07 (95% CI: 0.04–0.12), and diagnostic odds ratio of 157 (95% CI: 57–430). The overall sensitivity of blood NT-proBNP for diagnosis of HF was 0.92 (95% CI: 0.86–0.95), with a specificity of 0.88 (95% CI: 0.77–0.94), positive likelihood ratio of 7.8 (95% CI: 3.7–16.3), negative likelihood ratio of 0.10 (95% CI: 0.06–0.16), and diagnostic odds ratio of 81 (95% CI: 27–241). The diagnostic accuracy of PF MR-proANP and blood and PF BNP was not analyzed due to the small number of related studies. Conclusions BNP, NT-proBNP, and MR-proANP, either in blood or PF, are effective tools for diagnosis of HF. Additional studies are needed to rigorously evaluate the diagnostic accuracy of PF and blood MR-proANP and BNP for the diagnosis of HF. PMID:26244664

  15. Total nucleated cell and leukocyte differential counts in canine pleural and peritoneal fluid and equine synovial fluid samples: comparison of automated and manual methods.

    PubMed

    Brudvig, Jean M; Swenson, Cheryl L

    2015-12-01

    Rapid and precise measurement of total and differential nucleated cell counts is a crucial diagnostic component of cavitary and synovial fluid analyses. The objectives of this study included (1) evaluation of reliability and precision of canine and equine fluid total nucleated cell count (TNCC) determined by the benchtop Abaxis VetScan HM5, in comparison with the automated reference instruments ADVIA 120 and the scil Vet abc, respectively, and (2) comparison of automated with manual canine differential nucleated cell counts. The TNCC and differential counts in canine pleural and peritoneal, and equine synovial fluids were determined on the Abaxis VetScan HM5 and compared with the ADVIA 120 and Vet abc analyzer, respectively. Statistical analyses included correlation, least squares fit linear regression, Passing-Bablok regression, and Bland-Altman difference plots. In addition, precision of the total cell count generated by the VetScan HM5 was determined. Agreement was excellent without significant constant or proportional bias for canine cavitary fluid TNCC. Automated and manual differential counts had R(2)  < .5 for individual cell types (least squares fit linear regression). Equine synovial fluid TNCC agreed but with some bias due to the VetScan HM5 overestimating TNCC compared to the Vet abc. Intra-assay precision of the VetScan HM5 in 3 fluid samples was 2-31%. The Abaxis VetScan HM5 provided rapid, reliable TNCC for canine and equine fluid samples. The differential nucleated cell count should be verified microscopically as counts from the VetScan HM5 and also from the ADVIA 120 were often incorrect in canine fluid samples. © 2015 American Society for Veterinary Clinical Pathology.

  16. Performance of automated multiplex PCR using sonication fluid for diagnosis of periprosthetic joint infection: a prospective cohort.

    PubMed

    Renz, Nora; Feihl, Susanne; Cabric, Sabrina; Trampuz, Andrej

    2017-12-01

    Sonication of explanted prostheses improved the microbiological diagnosis of periprosthetic joint infections (PJI). We evaluated the performance of automated multiplex polymerase chain reaction (PCR) using sonication fluid for the microbiological diagnosis of PJI. In a prospective cohort using uniform definition criteria for PJI, explanted joint prostheses were investigated by sonication and the resulting sonication fluid was analyzed by culture and multiplex PCR. McNemar's Chi-squared test was used to compare the performance of diagnostic tests. Among 111 patients, PJI was diagnosed in 78 (70%) and aseptic failure in 33 (30%). For the diagnosis of PJI, the sensitivity and specificity of periprosthetic tissue culture was 51 and 100%, of sonication fluid culture 58 and 100%, and of sonication fluid PCR 51 and 94%, respectively. Among 70 microorganisms, periprosthetic tissue culture grew 52 (74%), sonication fluid culture grew 50 (71%) and sonication fluid PCR detected 37 pathogens (53%). If only organisms are considered, for which primers are included in the test panel, PCR detected 37 of 58 pathogens (64%). The sonication fluid PCR missed 19 pathogens (predominantly oral streptococci and anaerobes), whereas 7 additional microorganisms were detected only by PCR (including Cutibacterium spp. and coagulase-negative staphylococci). The performance of multiplex PCR using sonication fluid is comparable to culture of periprosthetic tissue or sonication fluid. The advantages of PCR are short processing time (< 5 h) and fully automated procedure. However, culture technique is still needed due to the low sensitivity and the need of comprehensive susceptibility testing. Modification of primers or inclusion of additional ones may improve the performance of PCR, especially of low-virulent organisms.

  17. When is acute persistent cough in school-age children and adults whooping cough? A prospective case series study.

    PubMed

    Philipson, Kathryn; Goodyear-Smith, Felicity; Grant, Cameron C; Chong, Angela; Turner, Nikki; Stewart, Joanna

    2013-08-01

    Pertussis is a vaccine modified disease in most age groups and hence subtle in its presentation. Current diagnostic approaches require relatively invasive sampling. To determine the incidence of B. pertussis infection among people aged 5-49 years identified in primary care with acute persistent cough using an oral fluid based diagnostic test. Active surveillance of acute persistent cough of 2 weeks duration or greater was established in Auckland, New Zealand from May to October 2011. The 15 participating primary care practices provided care for a socioeconomically diverse population. Recent B. pertussis infection was determined by measurement of IgG antibodies to pertussis toxin (PT) in an oral fluid sample. An IgG antibody titre to PT of ≥70 arbitrary units defined recent infection. Participants reported symptoms at presentation and kept a cough diary. A total of 226 participants were enrolled: 70 (31%) were children (5-16 years) and 156 (69%) were adults (17-49 years). Oral fluid samples were obtained from 225 participants. Ten per cent (23/225) had recent B. pertussis infection including a larger proportion of children than adults (17% versus 7%, P = 0.003). Neither cough duration nor any individual symptom discriminated between those with and without recent B. pertussis infection. Pertussis is a frequent cause of acute persistent cough presenting to primary care. Clinical differentiation of pertussis from other causes of acute persistent cough is difficult. An oral fluid based diagnostic test, which is less invasive than other diagnostic approaches, has high acceptability in primary care.

  18. When is acute persistent cough in school-age children and adults whooping cough?

    PubMed Central

    Philipson, Kathryn; Goodyear-Smith, Felicity; Grant, Cameron C; Chong, Angela; Turner, Nikki; Stewart, Joanna

    2013-01-01

    Background Pertussis is a vaccine modified disease in most age groups and hence subtle in its presentation. Current diagnostic approaches require relatively invasive sampling. Aim To determine the incidence of B. pertussis infection among people aged 5–49 years identified in primary care with acute persistent cough using an oral fluid based diagnostic test. Design and setting Active surveillance of acute persistent cough of 2 weeks duration or greater was established in Auckland, New Zealand from May to October 2011. The 15 participating primary care practices provided care for a socioeconomically diverse population. Method Recent B. pertussis infection was determined by measurement of IgG antibodies to pertussis toxin (PT) in an oral fluid sample. An IgG antibody titre to PT of ≥70 arbitrary units defined recent infection. Participants reported symptoms at presentation and kept a cough diary. Results A total of 226 participants were enrolled: 70 (31%) were children (5–16 years) and 156 (69%) were adults (17–49 years). Oral fluid samples were obtained from 225 participants. Ten per cent (23/225) had recent B. pertussis infection including a larger proportion of children than adults (17% versus 7%, P = 0.003). Neither cough duration nor any individual symptom discriminated between those with and without recent B. pertussis infection. Conclusion Pertussis is a frequent cause of acute persistent cough presenting to primary care. Clinical differentiation of pertussis from other causes of acute persistent cough is difficult. An oral fluid based diagnostic test, which is less invasive than other diagnostic approaches, has high acceptability in primary care. PMID:23972198

  19. Bench-top validation testing of selected immunological and molecular Renibacterium salmoninarum diagnostic assays by comparison with quantitative bacteriological culture

    USGS Publications Warehouse

    Elliott, D.G.; Applegate, L.J.; Murray, A.L.; Purcell, M.K.; McKibben, C.L.

    2013-01-01

    No gold standard assay exhibiting error-free classification of results has been identified for detection of Renibacterium salmoninarum, the causative agent of salmonid bacterial kidney disease. Validation of diagnostic assays for R. salmoninarum has been hindered by its unique characteristics and biology, and difficulties in locating suitable populations of reference test animals. Infection status of fish in test populations is often unknown, and it is commonly assumed that the assay yielding the most positive results has the highest diagnostic accuracy, without consideration of misclassification of results. In this research, quantification of R. salmoninarum in samples by bacteriological culture provided a standardized measure of viable bacteria to evaluate analytical performance characteristics (sensitivity, specificity and repeatability) of non-culture assays in three matrices (phosphate-buffered saline, ovarian fluid and kidney tissue). Non-culture assays included polyclonal enzyme-linked immunosorbent assay (ELISA), direct smear fluorescent antibody technique (FAT), membrane-filtration FAT, nested polymerase chain reaction (nested PCR) and three real-time quantitative PCR assays. Injection challenge of specific pathogen-free Chinook salmon, Oncorhynchus tshawytscha (Walbaum), with R. salmoninarum was used to estimate diagnostic sensitivity and specificity. Results did not identify a single assay demonstrating the highest analytical and diagnostic performance characteristics, but revealed strengths and weaknesses of each test.

  20. DNA Methylation Analysis of the SHOX2 and RASSF1A Panel in Bronchoalveolar Lavage Fluid for Lung Cancer Diagnosis

    PubMed Central

    Zhang, Chenzi; Yu, Wenjun; Wang, Lin; Zhao, Mingna; Guo, Qiaomei; Lv, Shaogang; Hu, Xiaomeng; Lou, Jiatao

    2017-01-01

    Introduction: Currently the majority of lung cancer patients are diagnosed as advanced diseases for no sensitive and specific biomarkers exist, noninvasive biomarkers with high sensitivity and specificity are urgently needed in lung cancer diagnosis. Bronchoscopy is a standard procedure of the diagnostic work-up of patients with suspected lung cancer despite of the limited diagnostic accuracy. Besides, epigenetic changes through DNA methylation play an important role in tumorigenesis. Thus, we examined the aberrant methylation of the SHOX2 and RASSF1A in bronchoalveolar lavage fluid (BALF) in comparing with conventional cytology examination and serum CEA in order to evaluate the new diagnostic method. Patients and Methods: BALF and serum samples were collected from 322 patients at the time of diagnosis, 284 of them were pathologically confirmed lung cancer, 35 were benign lung diseases and 3 were malignancies in other systems. For all of the 322 patients, the methylation status of the SHOX2 and RASSF1A gene were detected by a new RT-PCR platform and then confirmed by sanger sequencing. Serum CEA were detected using electrochemiluminescence immunoassay. Results: Profiling data showed the consistency of RT-PCR and sanger sequencing in detecting the methylation of the SHOX2 and RASSF1A. Besides, the combination of SHOX2 and RASSF1A methylation in BALF yielded a diagnostic sensitivity of 81.0% and specificity of 97.4%. When compared with established cytology examination (sensitivity: 68.3%, specificity: 97.4%) and serum biomarker carcinoembryonic antigen (CEA) (sensitivity: 30.6%, specificity: 100.0%), the SHOX2 and RASSF1A methylation panel showed the highest diagnostic efficiency. Notably, the combination of cytology and the SHOX2 and RASSF1A methylation panel could significantly improve the diagnostic efficacy. Conclusion: The methylation analysis of the SHOX2 and RASSF1A panel in BALF with RT-PCR achieved a satisfactory sensitivity and specificity in lung cancer diagnosis, especially in an early stage. It could be used as a promising noninvasive biomarker for auxiliary diagnosis of lung cancer. PMID:29151944

  1. Subacute Sclerosing Panencephalitis in an Infant: Diagnostic Role of Viral Genome Analysis

    PubMed Central

    Baram, Tallie Z.; Gonzalez-Gomez, Ignacio; Xie, Zong-De; Yao, Dapeng; Gilles, Floyd H.; Nelson, Marvin D.; Nguyen, Hahn T.; Peters, Julius

    2013-01-01

    Subacute sclerosing panencephalitis (SSPE) is related to “defective” measles virus or vaccination, though an association with parainfluenza viruses has been reported. SSPE is characterized by a slow, erratic course and elevated cerebrospinal fluid measles titers. An immunocompetent, vaccinated infant, with onset of symptoms in parainfiuenza virus season and a catastrophic course is described. Cerebrospinal fluid titers were negative, but postmortem brain had typical SSPE lesions. Patient brain-derived RNA, subjected to reverse transcription followed by polymerase chain reaction yielded polymerase chain reaction products with measles virus but not parainfluenza virus genes. The sequenced fragment revealed multiple mutations, typical for SSPE. SSPE can thus present in infants, with short latency and no cerebrospinal fluid antibodies. Viral genomic analysis may be diagnostic, permitting early therapy. PMID:8024248

  2. Evaluation of a multiplex real-time PCR for detection of four bacterial agents commonly associated with bovine respiratory disease in bronchoalveolar lavage fluid.

    PubMed

    Wisselink, Henk J; Cornelissen, Jan B W J; van der Wal, Fimme J; Kooi, Engbert A; Koene, Miriam G; Bossers, Alex; Smid, Bregtje; de Bree, Freddy M; Antonis, Adriaan F G

    2017-07-13

    Pasteurella multocida, Mannheimia haemolytica, Histophilus somni and Trueperella pyogenes are four bacterial agents commonly associated with bovine respiratory disease (BRD). In this study a bacterial multiplex real-time PCR (the RespoCheck PCR) was evaluated for the detection in bronchoalveolar lavage fluid (BALF) of these four bacterial agents. The analytical sensitivity of the multiplex real-time PCR assay determined on purified DNA and on bacterial cells of the four target pathogens was one to ten fg DNA/assay and 4 × 10 -1 to 2 × 10 0  CFU/assay. The analytical specificity of the test was, as evaluated on a collection of 118 bacterial isolates, 98.3% for M. haemolytica and 100% for the other three target bacteria. A set of 160 BALF samples of calves originating from ten different herds with health problems related to BRD was examined with bacteriological methods and with the RespoCheck PCR. Using bacteriological examination as the gold standard, the diagnostic sensitivities and specificities of the four bacterial agents were respectively between 0.72 and 1.00 and between 0.70 and 0.99. Kappa values for agreement between results of bacteriological examination and PCRs were low for H. somni (0.17), moderate for P. multocida (0.52) and M. haemolytica (0.57), and good for T. pyogenes (0.79). The low and moderate kappa values seemed to be related to limitations of the bacteriological examination, this was especially the case for H. somni. It was concluded that the RespoCheck PCR assay is a valuable diagnostic tool for the simultaneous detection of the four bacterial agents in BALF of calves.

  3. The Esophagiome: concept, status, and future perspectives.

    PubMed

    Gregersen, Hans; Liao, Donghua; Brasseur, James G

    2016-09-01

    The term "Esophagiome" is meant to imply a holistic, multiscale treatment of esophageal function from cellular and muscle physiology to the mechanical responses that transport and mix fluid contents. The development and application of multiscale mathematical models of esophageal function are central to the Esophagiome concept. These model elements underlie the development of a "virtual esophagus" modeling framework to characterize and analyze function and disease by quantitatively contrasting normal and pathophysiological function. Functional models incorporate anatomical details with sensory-motor properties and functional responses, especially related to biomechanical functions, such as bolus transport and gastrointestinal fluid mixing. This brief review provides insight into Esophagiome research. Future advanced models can provide predictive evaluations of the therapeutic consequences of surgical and endoscopic treatments and will aim to facilitate clinical diagnostics and treatment. © 2016 New York Academy of Sciences.

  4. Adenosquamous carcinoma of the lung diagnosed by cytology?: a diagnostic dilemma.

    PubMed

    Shelton, David A; Rana, Durgesh N; Holbrook, Miles; Taylor, Paul; Bailey, Simon

    2012-09-01

    Adenosquamous cell carcinomas of the lung are rare tumours and are associated with a poor prognosis compared to other non-small cell carcinomas. We report a case of a solitary lung carcinoma evaluated by bronchial brush and lavage cytology, bronchial biopsy and pleural fluid cytology. Cytological assessment of the pleural fluid demonstrated non-small cell carcinoma and immunohistochemical staining confirmed a metastatic lung adenocarcinoma. The bronchial brush and lavage specimens, however, demonstrated the cytomorphological features of squamous cell carcinoma, which was confirmed by the bronchial biopsy. The finding of a mixed squamous and glandular component predicts a poor prognosis for this patient. The identification of a squamous component with the non-small cell carcinoma is important as this excludes the patient from anti-VEGF monoclonal antibody treatment due to the increased risk of haemorrhage. Copyright © 2011 Wiley Periodicals, Inc.

  5. Solute Nucleation and Growth in Supercritical Fluid Mixtures

    NASA Technical Reports Server (NTRS)

    Smedley, Gregory T.; Wilemski, Gerald; Rawlins, W. Terry; Joshi, Prakash; Oakes, David B.; Durgin, William W.

    1996-01-01

    This research effort is directed toward two primary scientific objectives: (1) to determine the gravitational effect on the measurement of nucleation and growth rates near a critical point and (2) to investigate the nucleation process in supercritical fluids to aid in the evaluation and development of existing theoretical models and practical applications. A nucleation pulse method will be employed for this investigation using a rapid expansion to a supersaturated state that is maintained for approximately 1 ms followed by a rapid recompression to a less supersaturated state that effectively terminates nucleation while permitting growth to continue. Nucleation, which occurs during the initial supersaturated state, is decoupled from growth by producing rapid pressure changes. Thermodynamic analysis, condensation modeling, apparatus design, and optical diagnostic design necessary for the initiation of a theoretical and experimental investigation of naphthalene nucleation from supercritical CO2 have been completed.

  6. Rapid diagnosis of cryptococcal meningitis by use of lateral flow assay on cerebrospinal fluid samples: influence of the high-dose "hook" effect.

    PubMed

    Lourens, Adré; Jarvis, Joseph N; Meintjes, Graeme; Samuel, Catherine M

    2014-12-01

    Cryptococcal meningitis is the most frequent cause of meningitis and a major cause of mortality in HIV-infected adults in Africa. This study evaluated the performance of the lateral flow assay (LFA) on cerebrospinal fluid (CSF) samples for the diagnosis of cryptococcal meningitis against that of existing diagnostic tests. LFA performed on 465 undiluted CSF samples had a sensitivity of 91%. When the LFA was paired with Gram staining, a sensitivity of 100% was achieved after implementation of a dilution step for samples with negative LFA results and the presence of yeasts on microscopy. Microscopy is essential for preventing the reporting of false-negative results due to the high-dose "hook" effect. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  7. Oral vs. salivary diagnostics

    NASA Astrophysics Data System (ADS)

    Marques, Joana; Corby, Patricia M.; Barber, Cheryl A.; Abrams, William R.; Malamud, Daniel

    2015-05-01

    The field of "salivary diagnostics" includes studies utilizing samples obtained from a variety of sources within the oral cavity. These samples include; whole unstimulated saliva, stimulated whole saliva, duct saliva collected directly from the parotid, submandibular/sublingual glands or minor salivary glands, swabs of the buccal mucosa, tongue or tonsils, and gingival crevicular fluid. Many publications state "we collected saliva from subjects" without fully describing the process or source of the oral fluid. Factors that need to be documented in any study include the time of day of the collection, the method used to stimulate and collect the fluid, and how much fluid is being collected and for how long. The handling of the oral fluid during and post-collection is also critical and may include addition of protease or nuclease inhibitors, centrifugation, and cold or frozen storage prior to assay. In an effort to create a standard protocol for determining a biomarker's origin we carried out a pilot study collecting oral fluid from 5 different sites in the mouth and monitoring the concentrations of pro- and anti-inflammatory cytokines detected using MesoScaleDiscovery (MSD) electrochemiluminesence assays. Our data suggested that 3 of the cytokines are primarily derived from the submandibular gland, while 7 of the cytokines come from a source other than the major salivary glands such as the minor salivary glands or cells in the oral mucosae. Here we review the literature on monitoring biomarkers in oral samples and stress the need for determining the blood/saliva ratio when a quantitative determination is needed and suggest that the term oral diagnostic be used if the source of an analyte in the oral cavity is unknown.

  8. Clinical Diagnostic Utility of IP-10 and LAM Antigen Levels for the Diagnosis of Tuberculous Pleural Effusions in a High Burden Setting

    PubMed Central

    Dheda, Keertan; Van-Zyl Smit, Richard N.; Sechi, Leonardo A.; Badri, Motasim; Meldau, Richard; Symons, Gregory; Khalfey, Hoosein; Carr, Igshaan; Maredza, Alice; Dawson, Rodney; Wainright, Helen; Whitelaw, Andrew; Bateman, Eric D.; Zumla, Alimuddin

    2009-01-01

    Background Current tools for the diagnosis of tuberculosis pleural effusions are sub-optimal. Data about the value of new diagnostic technologies are limited, particularly, in high burden settings. Preliminary case control studies have identified IFN-γ-inducible-10kDa protein (IP-10) as a promising diagnostic marker; however, its diagnostic utility in a day-to-day clinical setting is unclear. Detection of LAM antigen has not previously been evaluated in pleural fluid. Methods We investigated the comparative diagnostic utility of established (adenosine deaminase [ADA]), more recent (standardized nucleic-acid-amplification-test [NAAT]) and newer technologies (a standardized LAM mycobacterial antigen-detection assay and IP-10 levels) for the evaluation of pleural effusions in 78 consecutively recruited South African tuberculosis suspects. All consenting participants underwent pleural biopsy unless contra-indicated or refused. The reference standard comprised culture positivity for M. tuberculosis or histology suggestive of tuberculosis. Principal Findings Of 74 evaluable subjects 48, 7 and 19 had definite, probable and non-TB, respectively. IP-10 levels were significantly higher in TB vs non-TB participants (p<0.0001). The respective outcomes [sensitivity, specificity, PPV, NPV %] for the different diagnostic modalities were: ADA at the 30 IU/L cut-point [96; 69; 90; 85], NAAT [6; 93; 67; 28], IP-10 at the 28,170 pg/ml ROC-derived cut-point [80; 82; 91; 64], and IP-10 at the 4035 pg/ml cut-point [100; 53; 83; 100]. Thus IP-10, using the ROC-derived cut-point, missed ∼20% of TB cases and mis-diagnosed ∼20% of non-TB cases. By contrast, when a lower cut-point was used a negative test excluded TB. The NAAT had a poor sensitivity but high specificity. LAM antigen-detection was not diagnostically useful. Conclusion Although IP-10, like ADA, has sub-optimal specificity, it may be a clinically useful rule-out test for tuberculous pleural effusions. Larger multi-centric studies are now required to confirm our findings. PMID:19277111

  9. Specific IgE in tear fluid and features of allergic conjunctivitis.

    PubMed

    Mimura, Tatsuya; Yamagami, Satoru; Kamei, Yuko; Goto, Mari; Matsubara, Masao

    2013-09-01

    The level of specific class E immunoglobulins (IgE) in tear fluid is a useful diagnostic indicator for allergic conjunctivitis, but it is still unclear whether the measurement of tear fluid IgE is helpful for assessing the severity of allergic conjunctivitis. In this study, we evaluated the relation between tear fluid levels of specific IgE and features of allergic conjunctivitis. A prospective, nonrandomized, cross-sectional study was conducted in patients with allergic conjunctivitis (n = 55, allergic group) and age- and sex-matched healthy control subjects (n = 50, control group). Levels of specific IgE for cedar pollen, cat epithelium/dander and Dermatophagoides pteronyssinus were measured in tear fluid with the Immfast Check J1®. A severity score (0, 1, 2 or 3) was assigned for various changes of the palpebral and bulbar conjunctiva, as well as for limbal and corneal lesions. The levels of specific IgE for both cedar pollen, and D. pteronyssinus were significantly higher in the allergic group compared with the control group (p < 0.0001), while the level of specific IgE for cat epithelium/dander showed no significant difference between the two groups (p = 0.0777). When IgE levels were divided into four classes, the classes for both D. Pteronyssinus and cat epithelium/dander IgE were correlated with four features of allergic conjunctivitis. On the other hand, no correlation was found between the class of cedar pollen IgE and any of the features of allergic conjunctivitis. This study demonstrated that measurement of specific IgE in tear fluid may be useful for determining the severity of allergic conjunctivitis induced by indoor allergens. Although measurement of IgE in tear fluid is only a supplemental tool for evaluating the clinical activity of allergic conjunctivitis, the test can be useful for detecting specific IgE antibodies responsible for this condition.

  10. Comparing an accelerated 3D fast spin-echo sequence (CS-SPACE) for knee 3-T magnetic resonance imaging with traditional 3D fast spin-echo (SPACE) and routine 2D sequences.

    PubMed

    Altahawi, Faysal F; Blount, Kevin J; Morley, Nicholas P; Raithel, Esther; Omar, Imran M

    2017-01-01

    To compare a faster, new, high-resolution accelerated 3D-fast-spin-echo (3D-FSE) acquisition sequence (CS-SPACE) to traditional 2D and high-resolution 3D sequences for knee 3-T magnetic resonance imaging (MRI). Twenty patients received knee MRIs that included routine 2D (T1, PD ± FS, T2-FS; 0.5 × 0.5 × 3 mm 3 ; ∼10 min), traditional 3D FSE (SPACE-PD-FS; 0.5 × 0.5 × 0.5 mm 3 ; ∼7.5 min), and accelerated 3D-FSE prototype (CS-SPACE-PD-FS; 0.5 × 0.5 × 0.5 mm 3 ; ∼5 min) acquisitions on a 3-T MRI system (Siemens MAGNETOM Skyra). Three musculoskeletal radiologists (MSKRs) prospectively and independently reviewed the studies with graded surveys comparing image and diagnostic quality. Tissue-specific signal-to-noise ratios (SNR) and contrast-to-noise ratios (CNR) were also compared. MSKR-perceived diagnostic quality of cartilage was significantly higher for CS-SPACE than for SPACE and 2D sequences (p < 0.001). Assessment of diagnostic quality of menisci and synovial fluid was higher for CS-SPACE than for SPACE (p < 0.001). CS-SPACE was not significantly different from SPACE but had lower assessments than 2D sequences for evaluation of bones, ligaments, muscles, and fat (p ≤ 0.004). 3D sequences had higher spatial resolution, but lower overall assessed contrast (p < 0.001). Overall image quality from CS-SPACE was assessed as higher than SPACE (p = 0.007), but lower than 2D sequences (p < 0.001). Compared to SPACE, CS-SPACE had higher fluid SNR and CNR against all other tissues (all p < 0.001). The CS-SPACE prototype allows for faster isotropic acquisitions of knee MRIs over currently used protocols. High fluid-to-cartilage CNR and higher spatial resolution over routine 2D sequences may present a valuable role for CS-SPACE in the evaluation of cartilage and menisci.

  11. Application of a Novel Diagnostic Rule in the Differential Diagnosis between Acute Gouty Arthritis and Septic Arthritis.

    PubMed

    Lee, Kwang-Hoon; Choi, Sang-Tae; Lee, Soo-Kyung; Lee, Joo-Hyun; Yoon, Bo-Young

    2015-06-01

    Septic arthritis and gout are major diseases that should be suspected in patients with acute monoarthritis. These two diseases are clinically similar and often indistinguishable without the help of synovial fluid analysis. Recently, a novel diagnostic rule for gout without synovial fluid analysis was developed and showed relevant performances. This study aimed to determine whether this diagnostic rule could perform well in distinguishing gout from septic arthritis. The diagnostic rule comprises 7 clinical and laboratory variables, each of which is given a specified score. The probability of gout is classified into 3 groups according to the sum of the scores: high (≥ 8), intermediate (> 4 to < 8) and low probability (≤ 4). In this retrospective study, we applied this diagnostic rule to 136 patients who presented as acute monoarthritis and were subsequently diagnosed as acute gout (n = 82) and septic arthritis (n = 54) based on synovial fluid analysis. The mean sum of scores of acute gout patients was significantly higher than that of those with septic arthritis (8.6 ± 0.2 vs. 3.6 ± 0.32, P < 0.001). Patients with acute gout had significantly more 'high', and less 'low' probabilities compared to those with septic arthritis (Eta[η]: 0.776). The prevalence of acute gouty arthritis, as confirmed by the presence of monosodium crystal, was 95.5% (61/64), 57.5% (19/33), and 5.1% (2/39) in high, intermediate and low probability group, respectively. The recently introduced diagnostic rule properly discriminates acute gout from septic arthritis. It may help physicians diagnose gout in cases difficult to be differentiated from septic arthritis.

  12. Evaluation of serum and pleural levels of endostatin and vascular epithelial growth factor in lung cancer patients with pleural effusion.

    PubMed

    Zhang, Yu; Yu, Li-Ke; Xia, Ning

    2012-03-01

    To evaluate the diagnostic value of endostatin (ES), vascular endothelial growth factor (VEGF) and carcinoembryonic antigen (CEA) in both serum and pleural effusion of lung cancer patients. Levels of ES, VEGF and CEA in 52 malignant pleural effusion due to lung cancer and 50 patients with non-malignant disease were measured by using sandwich enzyme-linked immunosorbent assay and microparticle enzyme immunoassay. The ES, VEGF and CEA levels in pleural effusion and serum, and their ratio (F/S) were higher in lung cancer group than that in benign group, and the differences were statistically significant (P<0.05). The diagnostic efficiency of ES+VEGF for lung cancer was superior to either single detection. The diagnostic efficiency of ES+VEGF+CEA was superior to either ES+VEGF or ES+CEA. The results suggest that ES, VEGF and CEA might be useful in the differentiation between benign and malignant pleural effusion due to lung cancer. In comparison with either single determination of concentration in serum or pleural fluid, the combined detection of two or three markers is of important clinical significance in the diagnosis of lung cancer. Copyright © 2012 Hainan Medical College. Published by Elsevier B.V. All rights reserved.

  13. Evaluation of the enterovirus laboratory surveillance system in Denmark, 2010 to 2013.

    PubMed

    Condell, Orla; Midgley, Sofie; Christiansen, Claus Bohn; Chen, Ming; Chen Nielsen, Xiaohui; Ellermann-Eriksen, Svend; Mølvadgaard, Mette; Schønning, Kristian; Vermedal Hoegh, Silje; Andersen, Peter Henrik; Voldstedlund, Marianne; Fischer, Thea Kølsen

    2016-05-05

    The primary aim of the Danish enterovirus (EV) surveillance system is to document absence of poliovirus infection. The conflict in Syria has left many children unvaccinated and movement from areas with polio cases to Europe calls for increased awareness to detect and respond to virus-transmission in a timely manner. We evaluate the national EV laboratory surveillance, to generate recommendations for system strengthening. The system was analysed for completeness of viral typing analysis and clinical information and timeliness of specimen collection, laboratory results and reporting of clinical information. Of 23,720 specimens screened, 2,202 (9.3%) were EV-positive. Submission of cerebrospinal fluid and faecal specimens from primary diagnostic laboratories was 79.5% complete (845/1,063), and varied by laboratory and patient age. EV genotypes were determined in 68.5% (979/1,430) of laboratory-confirmed cases, clinical information was available for 63.1% (903/1,430). Primary diagnostic results were available after a median of 1.4 days, typing results after 17 days, detailed clinical information after 33 days. The large number of samples typed demonstrated continued monitoring of EV-circulation in Denmark. The system could be strengthened by increasing the collection of supplementary faecal specimens, improving communication with primary diagnostic laboratories, adapting the laboratory typing methodology and collecting clinical information with electronic forms.

  14. Evaluation of predictive value of pleural CEA in patients with pleural effusions and histological findings: A prospective study and literature review.

    PubMed

    Tozzoli, Renato; Basso, Stefano M M; D'Aurizio, Federica; Metus, Paolo; Lumachi, Franco

    2016-11-01

    Pleural effusion recognizes heterogeneous etiology and pathogenesis and requires invasive diagnostic procedures. Usually, after pleural fluid analysis, 30-50% of patients with malignant pleural effusion exhibit negative pleural cytology, and the sensitivity of image-guided pleural needle-aspiration biopsy ranges between 60% and 70%. With the aim of differentiating between benign (BPE) and malignant (MPE) pleural effusions, several tumor markers have been assayed in the pleural fluid and the majority of studies focus on pleural carcinoembryonic antigen (p-CEA). The aims of this study were to evaluate (i) the diagnostic accuracy of p-CEA of patients with pleural effusions undergoing video-assisted thoracoscopic surgery (VATS) for diagnostic purpose, (ii) the relationship between p-CEA and serum CEA (s-CEA), and (iii) the usefulness of the p-CEA/s-CEA ratio in the diagnosis of malignant pleural effusions (MPE). We prospectively enrolled in the study 134 consecutive patients with pleural effusions, scheduled for having VATS and biopsy. The final diagnosis, based on histopathology of the VATS-guided specimens, was available for all patients. p-CEA and s-CEA was assayed with a chemiluminescence immunoassay method (CLIA), applied on the Maglumi 2000 Plus automated platform (SNIBE, Shenzen, China). The sensitivity and accuracy of p-CEA was significantly higher than that of pleural cytology at the same specificity comparing BPE with MPE and BPE with non-small lung cancer. The sensitivity of p-CEA and PC together reached 100% (BPE vs. NSCLC) and 91.5% (BPE vs. MPE excluding mesothelioma), respectively. The p-CEA measurement in patients with pleural effusion of uncertain etiology is a safe and cost-effective procedure, everywhere easily available, which may help clinicians in selecting patients for further evaluations. An elevated p-CEA level in a patient with pleural effusion and negative pleural cytology suggests the need of more invasive procedure (e.g. VATS-guided biopsies), whilst low p-CEA may support a follow-up. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  15. The Light Microscopy Module: An On-Orbit Multi-User Microscope Facility

    NASA Technical Reports Server (NTRS)

    Motil, Susan M.; Snead, John H.

    2002-01-01

    The Light Microscopy Module (LMM) is planned as a remotely controllable on-orbit microscope subrack facility, allowing flexible scheduling and operation of fluids and biology experiments within the Fluids and Combustion Facility (FCF) Fluids Integrated Rack (FIR) on the International Space Station (ISS). The LMM will be the first integrated payload with the FIR to conduct four fluid physics experiments. A description of the LMM diagnostic capabilities, including video microscopy, interferometry, laser tweezers, confocal, and spectrophotometry, will be provided.

  16. Methods and Compositions Based on Culturing Microorganisms in Low Sedimental Fluid Shear Conditions

    NASA Technical Reports Server (NTRS)

    Ott, C. Mark; Nickerson, Cheryl A.; Wilson, James W.; Sarker, Shameema; Nauman, Eric A.; Schurr, Michael J.; Nelman-Gonzalez, Mayra A.

    2012-01-01

    The benefits of applying a low sedimental fluid shear environment to manipulate microorganisms were examined. Microorganisms obtained from a low sedimental fluid shear culture, which exhibit modified phenotypic and molecular genetic characteristics, are useful for the development of novel and improved diagnostics, therapeutics, vaccines, and bio-industrial products. Furthermore, application of low sedimental fluid conditions to microorganisms permits identification of molecules uniquely expressed under these conditions, providing a basis for the design of new therapeutic targets.

  17. [Methods of protein gradient determination for diagnostic use in the clinical laboratory].

    PubMed

    Schulz, D; Rothenhöfer, C

    1982-02-25

    Computed quotients of the concentrations of individual proteins in serum and in cerebrospinal fluid recorded in a semilogarithmic way against the hydrodynamic radius of the molecules may be connected and so give lineals, the positions of which are believed to estimate the actual function of the blood-brain-barrier (Felgenhauer et al. 1974; 1976). It is demonstrated by examinations of different samples of blood and cerebrospinal fluid, that both the described method and the simple measurement of total protein in cerebrospinal fluid are of the same power in their application to estimate the function of the blood-brain-barrier. However, the method introduced by Felgenhauer et al. enables to demonstrate immunoglobulins not having reached the cerebrospinal fluid by entering from the blood stream and so giving rise to diagnose a local humoral immune response within the central nervous system. In this way the method of Felgenhauer et al. gives advantages to the diagnostics of neurological diseases.

  18. Pleural tuberculosis: medical thoracoscopy greatly increases the diagnostic accuracy

    PubMed Central

    Mori, Pier Anselmo; Majori, Maria; Anghinolfi, Miriam; Silini, Enrico Maria; Gnetti, Letizia; Motta, Federica; Larini, Sandra; Montecchini, Sara; Pisi, Roberta; Calderaro, Adriana

    2018-01-01

    Our objective was to evaluate the efficacy of a standardised work-up in the diagnosis of pleural tuberculosis (TB) that included fibreoptic bronchoscopy and medical thoracoscopy. A consecutive series of 52 pleural TB patients observed during the period 2001–2015 was evaluated retrospectively. 20 females, mean (range) age 39.7 (18–74) years, and 32 males, mean (range) age 45.75 (21–83) years, were included (28 non-EU citizens (53.8%)). The diagnosis of TB infections was established by identification (using stains, culture or molecular tests) of Mycobacterium tuberculosis in the pleura, sputum and/or bronchial specimens, or by evidence of caseous granulomas on pleural biopsies. Patients with and without lung lesions were considered separately. The diagnostic yield of the microbiological tests on pleural fluid was 17.3% (nine out of 52 patients). Among the 18 patients with lung lesions, bronchial samples (washing, lavage or biopsy) were positive in 50% of cases (nine patients). Cultures of pleural biopsies were positive in 63% of cases (29 out of 46 patients); pleural histology was relevant in all patients. Without pleural biopsy, a diagnosis would have been reached in 15 out of 52 patients (28.6%) and in four of them only following culture at 30–40 days. An integrated diagnostic work-up that includes all the diagnostic methods of interventional pulmonology is required for a diagnosis of pleural TB. In the majority of patients, a diagnosis can be reached only with pleural biopsy. PMID:29318136

  19. A standard test case suite for two-dimensional linear transport on the sphere: results from a collection of state-of-the-art schemes

    NASA Astrophysics Data System (ADS)

    Lauritzen, P. H.; Ullrich, P. A.; Jablonowski, C.; Bosler, P. A.; Calhoun, D.; Conley, A. J.; Enomoto, T.; Dong, L.; Dubey, S.; Guba, O.; Hansen, A. B.; Kaas, E.; Kent, J.; Lamarque, J.-F.; Prather, M. J.; Reinert, D.; Shashkin, V. V.; Skamarock, W. C.; Sørensen, B.; Taylor, M. A.; Tolstykh, M. A.

    2013-09-01

    Recently, a standard test case suite for 2-D linear transport on the sphere was proposed to assess important aspects of accuracy in geophysical fluid dynamics with a "minimal" set of idealized model configurations/runs/diagnostics. Here we present results from 19 state-of-the-art transport scheme formulations based on finite-difference/finite-volume methods as well as emerging (in the context of atmospheric/oceanographic sciences) Galerkin methods. Discretization grids range from traditional regular latitude-longitude grids to more isotropic domain discretizations such as icosahedral and cubed-sphere tessellations of the sphere. The schemes are evaluated using a wide range of diagnostics in idealized flow environments. Accuracy is assessed in single- and two-tracer configurations using conventional error norms as well as novel diagnostics designed for climate and climate-chemistry applications. In addition, algorithmic considerations that may be important for computational efficiency are reported on. The latter is inevitably computing platform dependent, The ensemble of results from a wide variety of schemes presented here helps shed light on the ability of the test case suite diagnostics and flow settings to discriminate between algorithms and provide insights into accuracy in the context of global atmospheric/ocean modeling. A library of benchmark results is provided to facilitate scheme intercomparison and model development. Simple software and data-sets are made available to facilitate the process of model evaluation and scheme intercomparison.

  20. A standard test case suite for two-dimensional linear transport on the sphere: results from a collection of state-of-the-art schemes

    NASA Astrophysics Data System (ADS)

    Lauritzen, P. H.; Ullrich, P. A.; Jablonowski, C.; Bosler, P. A.; Calhoun, D.; Conley, A. J.; Enomoto, T.; Dong, L.; Dubey, S.; Guba, O.; Hansen, A. B.; Kaas, E.; Kent, J.; Lamarque, J.-F.; Prather, M. J.; Reinert, D.; Shashkin, V. V.; Skamarock, W. C.; Sørensen, B.; Taylor, M. A.; Tolstykh, M. A.

    2014-01-01

    Recently, a standard test case suite for 2-D linear transport on the sphere was proposed to assess important aspects of accuracy in geophysical fluid dynamics with a "minimal" set of idealized model configurations/runs/diagnostics. Here we present results from 19 state-of-the-art transport scheme formulations based on finite-difference/finite-volume methods as well as emerging (in the context of atmospheric/oceanographic sciences) Galerkin methods. Discretization grids range from traditional regular latitude-longitude grids to more isotropic domain discretizations such as icosahedral and cubed-sphere tessellations of the sphere. The schemes are evaluated using a wide range of diagnostics in idealized flow environments. Accuracy is assessed in single- and two-tracer configurations using conventional error norms as well as novel diagnostics designed for climate and climate-chemistry applications. In addition, algorithmic considerations that may be important for computational efficiency are reported on. The latter is inevitably computing platform dependent. The ensemble of results from a wide variety of schemes presented here helps shed light on the ability of the test case suite diagnostics and flow settings to discriminate between algorithms and provide insights into accuracy in the context of global atmospheric/ocean modeling. A library of benchmark results is provided to facilitate scheme intercomparison and model development. Simple software and data sets are made available to facilitate the process of model evaluation and scheme intercomparison.

  1. Diagnostic value of creatine kinase activity in canine cerebrospinal fluid.

    PubMed

    Ferreira, Alexandra

    2016-10-01

    This study aimed to determine whether creatine kinase (CK) activity in cerebrospinal fluid (CSF) has diagnostic value for various groups of neurological conditions or for different anatomical areas of the nervous system (NS). The age, breed, results of CSF analysis, and diagnosis of 578 canine patients presenting with various neurological conditions between January 2009 and February 2015 were retrospectively collected. The cases were divided according to anatomical areas of the nervous system, i.e., brain, spinal cord, and peripheral nervous system, and into groups according to the nature of the condition diagnosed: vascular, immune/inflammatory/infectious, traumatic, toxic, anomalous, metabolic, idiopathic, neoplastic, and degenerative. Statistical analysis showed that CSF-CK alone cannot be used as a diagnostic tool and that total proteins in the CSF and red blood cells (RBCs) do not have a significant relationship with the CSF-CK activity. CSF-CK did not have a diagnostic value for different disease groups or anatomical areas of the nervous system.

  2. Meta-Review of CSF Core Biomarkers in Alzheimer’s Disease: The State-of-the-Art after the New Revised Diagnostic Criteria

    PubMed Central

    Ferreira, Daniel; Perestelo-Pérez, Lilisbeth; Westman, Eric; Wahlund, Lars-Olof; Sarría, Antonio; Serrano-Aguilar, Pedro

    2014-01-01

    Background: Current research criteria for Alzheimer’s disease (AD) include cerebrospinal fluid (CSF) biomarkers into the diagnostic algorithm. However, spreading their use to the clinical routine is still questionable. Objective: To provide an updated, systematic and critical review on the diagnostic utility of the CSF core biomarkers for AD. Data sources: MEDLINE, PreMedline, EMBASE, PsycInfo, CINAHL, Cochrane Library, and CRD. Eligibility criteria: (1a) Systematic reviews with meta-analysis; (1b) Primary studies published after the new revised diagnostic criteria; (2) Evaluation of the diagnostic performance of at least one CSF core biomarker. Results: The diagnostic performance of CSF biomarkers is generally satisfactory. They are optimal for discriminating AD patients from healthy controls. Their combination may also be suitable for mild cognitive impairment (MCI) prognosis. However, CSF biomarkers fail to distinguish AD from other forms of dementia. Limitations: (1) Use of clinical diagnosis as standard instead of pathological postmortem confirmation; (2) variability of methodological aspects; (3) insufficiently long follow-up periods in MCI studies; and (4) lower diagnostic accuracy in primary care compared with memory clinics. Conclusion: Additional work needs to be done to validate the application of CSF core biomarkers as they are proposed in the new revised diagnostic criteria. The use of CSF core biomarkers in clinical routine is more likely if these limitations are overcome. Early diagnosis is going to be of utmost importance when effective pharmacological treatment will be available and the CSF core biomarkers can also be implemented in clinical trials for drug development. PMID:24715863

  3. Species and temperature measurement in H2/O2 rocket flow fields by means of Raman scattering diagnostics

    NASA Technical Reports Server (NTRS)

    Degroot, Wim A.; Weiss, Jonathan M.

    1992-01-01

    Validation of Computational Fluid Dynamics (CFD) codes developed for prediction and evaluation of rocket performance is hampered by a lack of experimental data. Non-intrusive laser based diagnostics are needed to provide spatially and temporally resolved gas dynamic and fluid dynamic measurements. This paper reports the first non-intrusive temperature and species measurements in the plume of a 110 N gaseous hydrogen/oxygen thruster at and below ambient pressures, obtained with spontaneous Raman spectroscopy. Measurements at 10 mm downstream of the exit plane are compared with predictions from a numerical solution of the axisymmetric Navier-Stokes and species transport equations with chemical kinetics, which fully model the combustor-nozzle-plume flowfield. The experimentally determined oxygen number density at the centerline at 10 mm downstream of the exit plane is four times that predicted by the model. The experimental number density data fall between those numerically predicted for the exit and 10 mm downstream planes in both magnitude and radial gradient. The predicted temperature levels are within 10 to 15 percent of measured values. Some of the discrepancies between experimental data and predictions result from not modeling the three dimensional core flow injection mixing process, facility back pressure effects, and possible diffuser-thruster interactions.

  4. Clinical value of jointly detection serum lactate dehydrogenase/pleural fluid adenosine deaminase and pleural fluid carcinoembryonic antigen in the identification of malignant pleural effusion.

    PubMed

    Zhang, Fan; Hu, Lijuan; Wang, Junjun; Chen, Jian; Chen, Jie; Wang, Yumin

    2017-09-01

    Limited data are available for the diagnostic value, and for the diagnostic sensitivity and specificity of joint detection of serum lactate dehydrogenase (sLDH)/pleural fluid adenosine deaminase (pADA) and pleural fluid carcinoembryonic antigen (pCEA) in malignant pleural effusion (MPE). We collected 987 pleural effusion specimens (of which 318 were malignant pleural effusion, 374 were tubercular pleural effusion, and 295 were parapneumonic effusion specimens) from the First Affiliated Hospital of Wenzhou Medical University from July 2012 to March 2016. The pADA, sLDH, pleural fluid LDH (pLDH), serum C-reactive protein (sCRP), pleural fluid protein, pCEA, white blood cell (WBC), and red blood cell (RBC) were analyzed, and the clinical data of each group were collected for statistical analysis. The level of sLDH/pADA, pCEA, and RBC from the MPE group was markedly higher than the tuberculosis pleural effusion (TB) group (Mann-Whitney U=28422.000, 9278.000, 30518, P=.000, .000, .000) and the parapneumonic pleural fluid group (Mann-Whitney U=5972.500, 7113.000, 36750.500, P=.000, .000, .000). The receiver operating characteristic curve ROC showed that the area under the ROC curve (AUC) (=0.924, 0.841) of pCEA and sLDH/pADA (cutoff=4.9, 10.6) were significantly higher than other markers for the diagnosis of MPE. Thus, joint detection of pCEA and sLDH/pADA suggested that the sensitivity, specificity, and AUC was 0.94, 81.70, and 94.32 at the cutoff 0.16 and diagnostic performance was higher than pCEA or sLDH/pADA. Joint detection of sLDH/pADA and pCEA can be used as a good indicator for the identification of benign and MPE with higher sensitivity and specificity than pCEA or sLDH/pADA. © 2016 Wiley Periodicals, Inc.

  5. Spectral luminescence analysis of amniotic fluid

    NASA Astrophysics Data System (ADS)

    Slobozhanina, Ekaterina I.; Kozlova, Nataly M.; Kasko, Leonid P.; Mamontova, Marina V.; Chernitsky, Eugene A.

    1997-12-01

    It is shown that the amniotic fluid has intensive ultra-violet luminescence caused by proteins. Along with it amniotic fluid radiated in the field of 380 - 650 nm with maxima at 430 - 450 nm and 520 - 560 nm. The first peak of luminescence ((lambda) exc equals 350 nm; (lambda) em equals 430 - 440 nm) is caused (most probably) by the presence in amniotic fluid of some hormones, NADH2 and NADPH2. A more long-wave component ((lambda) exc equals 460 nm; (lambda) em equals 520 - 560 nm) is most likely connected with the presence in amniotic fluid pigments (bilirubin connected with protein and other). It is shown that intensity and maximum of ultra-violet luminescence spectra of amniotic fluid in normality and at pathology are identical. However both emission spectra and excitation spectra of long-wave ((lambda) greater than 450 nm) luminescence of amniotic fluid from pregnant women with such prenatal abnormal developments of a fetus as anencephaly and spina bifida are too long-wave region in comparison with the norm. Results of research testify that spectral luminescent analysis of amniotic fluid can be used for screening of malformations of the neural tube. It is very difficult for a practical obstetrician to reveal pregnant women with a high risk of congenital malformations of the fetus. Apart from ultrasonic examination, cytogenetic examination of amniotic fluid and defumination of concentrations of alpha-fetoprotein and acetylcholin-esterases in the amniotic fluid and blood plasma are the most widely used diagnostic approaches. However, biochemical and cytogenetic diagnostic methods are time-consuming. In the present work spectral luminescence properties of the amniotic fluid are investigated to determine spectral parameters that can be used to reveal pregnant women with a high risk of congenital malformations of their offsprings.

  6. Clinical and cost implications of amyloid beta detection with amyloid beta positron emission tomography imaging in early Alzheimer's disease - the case of florbetapir.

    PubMed

    Hornberger, John; Bae, Jay; Watson, Ian; Johnston, Joe; Happich, Michael

    2017-04-01

    Amyloid beta (Aβ) positron emission tomography (PET) imaging helps estimate Aβ neuritic plaque density in patients with cognitive impairment who are under evaluation for Alzheimer's disease (AD). This study aims to evaluate the cost-effectiveness of the Aβ-PET scan as an adjunct to standard diagnostic assessment for diagnosis of AD in France, using florbetapir as an example. A state-transition probability analysis was developed adopting the French Health Technology Assessment (HTA) perspective per guidance. Parameters included test characteristics, rate of cognitive decline, treatment effect, costs, and quality of life. Additional scenarios assessed the validity of the analytical framework, including: (1) earlier evaluation/treatment; (2) cerebrospinal fluid (CSF) as a comparator; and (3) use of other diagnostic procedures. Outputs included differences in quality-adjusted life years (QALYs), costs, and incremental cost-effectiveness ratios (ICERs). All benefits and costs were discounted for time preferences. Sensitivity analyses were performed to assess the robustness of findings and key influencers of outcomes. Aβ-PET used as an adjunct to standard diagnostic assessment increased QALYs by 0.021 years and 10 year costs by €470 per patient. The ICER was €21,888 per QALY gained compared to standard diagnostic assessment alone. When compared with CSF, Aβ-PET costs €24,084 per QALY gained. In other scenarios, Aβ-PET was consistently cost-effective relative to the commonly used affordability threshold (€40,000 per QALY). Over 95% of simulations in the sensitivity analysis were cost-effective. Aβ-PET is projected to affordably increase QALYs from the French HTA perspective per guidance over a range of clinical scenarios, comparators, and input parameters.

  7. Exosome levels in human body fluids: A tumor marker by themselves?

    PubMed

    Cappello, Francesco; Logozzi, Mariantonia; Campanella, Claudia; Bavisotto, Celeste Caruso; Marcilla, Antonio; Properzi, Francesca; Fais, Stefano

    2017-01-01

    Despite considerable research efforts, the finding of reliable tumor biomarkers remains challenging and unresolved. In recent years a novel diagnostic biomedical tool with high potential has been identified in extracellular nanovesicles or exosomes. They are released by the majority of the cells and contain detailed molecular information on the cell of origin including tumor hallmarks. Exosomes can be isolated from easy accessible body fluids, and most importantly, they can provide several biomarkers, with different levels of specificity. Recent clinical evidence shows that the levels of exosomes released into body fluids may themselves represent a predictive/diagnostic of tumors, discriminating cancer patients from healthy subjects. The aim of this review is to highlight these latest challenging findings to provide novel and groundbreaking ideas for successful tumor early diagnosis and follow-up. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Hybrid microneedles devices for diagnostic and therapeutic applications: fabrication and preliminary results

    NASA Astrophysics Data System (ADS)

    Dardano, P.; Caliò, A.; Politi, J.; Di Palma, V.; Bevilacqua, M. F.; Rea, I.; Casalino, M.; Di Matteo, A.; Rendina, I.; De Stefano, L.

    2015-06-01

    Microneedles are newly developed biomedical devices, whose advantages are mainly in the non-invasiveness, discretion and versatility of use both as diagnostics and as therapeutics tool. In fact, they can be used both for drugs delivery in the interstitial fluids and for the analysis of the interstitial fluid. In this work we present the preliminary results for two devices based on micro needles in PolyEthylene (Glycol). The first for the drugs delivery includes a membrane whose optical reflected wavelength is related to the concentration of drug. Here, we present our preliminary result in diffusion of drugs between the membrane and the microneedles. The second device is gold coated and it works as electrode for the electrochemical detection of species in the interstitial fluid. A preliminary result in detection of glucose will be shown.

  9. Advanced Stimulated Scattering Measurements in Supercritical Fluids

    DTIC Science & Technology

    2006-09-01

    supercritical fluid measurement techniques. Ajay Agrawal, optical diagnostics. Mel Roquemore, turbine engines. Fred Schauer, pulse detonation propulsion...Lett. 87, 233902 (2001). 11. R. W. Gammon, H. L. Swinney, and H. Z. Cummins, "Brillouin scattering in carbon dioxide in the critical region," Phys. Rev...Stimulated Scattering Measurements in Supercritical F49620-03-C-0015 Fluids 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 61102F 6. AUTHOR(S) 5d

  10. ADMiER-ing thin but complex fluids

    NASA Astrophysics Data System (ADS)

    McDonnell, Amarin G.; Bhattacharjee, Pradipto K.; Pan, Sharadwata; Hill, David; Danquah, Michael K.; Friend, James R.; Yeo, Leslie Y.; Prabhakar, Ranganathan

    2011-12-01

    The Acoustics Driven Microfluidic Extensional Rheometer (ADMiER) utilises micro litre volumes of liquid, with viscosities as low as that of water, to create valid and observable extensional flows, liquid bridges that pinch off due to capillary forces in this case. ADMiER allows the study fluids that have been beyond conventional methods and also study more subtle fluid properties. We can observe polymeric fluids with solvent viscosities far below those previously testable, accentuating elastic effects. Also, it has enabled the testing of aqueous solutions of living motile particles, which significantly change fluid properties, opening up the potential for diagnostic applications.

  11. Proceedings of Workshop on Laser Diagnostics in Fluid Mechanics and Combustion

    NASA Astrophysics Data System (ADS)

    1993-10-01

    Proceedings of the Workshop on Laser Diagnostics in Fluid Mechanics and Combustion are presented. Topics included are: Accuracy of Laser Doppler Anemometry; Applications of Raman-Rayleigh-LIF Diagnostics in Combustion Research; Phase Doppler Anemometer Technique Concepts and Applications; CARS; Particle Image Velocimetry; Practical Consideration in the Use and Design of Laser Velocimetry Systems in Turbomachinery Applications; Phase Doppler Measurements of Gas-Particle Flow Through a Tube Bank; Degenerate Four Wave Mixing for Shock Tunnel Studies of Supersonic Combustion; Laser Induced Photodissociation and Fluorescence (LIPF) of Sodium Species Present in Coal Combustion; 3D Holographic Measurements Inside a Spark Ignition Engine; Laser Doppler Velocimeter Measurements in Compressible Flow; Bursting in a Tornado Vortex; Quantitative Imaging of OH and Temperature Using a Single Laser Source and Single Intensified Camera; and Laser Doppler Measurements Inside an Artificial Heart Valve.

  12. Microfluidic Sample Preparation for Diagnostic Cytopathology

    PubMed Central

    Mach, Albert J.; Adeyiga, Oladunni B.; Di Carlo, Dino

    2014-01-01

    The cellular components of body fluids are routinely analyzed to identify disease and treatment approaches. While significant focus has been placed on developing cell analysis technologies, tools to automate the preparation of cellular specimens have been more limited, especially for body fluids beyond blood. Preparation steps include separating, concentrating, and exposing cells to reagents. Sample preparation continues to be routinely performed off-chip by technicians, preventing cell-based point-of-care diagnostics, increasing the cost of tests, and reducing the consistency of the final analysis following multiple manually-performed steps. Here, we review the assortment of biofluids for which suspended cells are analyzed, along with their characteristics and diagnostic value. We present an overview of the conventional sample preparation processes for cytological diagnosis. We finally discuss the challenges and opportunities in developing microfluidic devices for the purpose of automating or miniaturizing these processes, with particular emphases on preparing large or small volume samples, working with samples of high cellularity, automating multi-step processes, and obtaining high purity subpopulations of cells. We hope to convey the importance of and help identify new research directions addressing the vast biological and clinical applications in preparing and analyzing the array of available biological fluids. Successfully addressing the challenges described in this review can lead to inexpensive systems to improve diagnostic accuracy while simultaneously reducing overall systemic healthcare costs. PMID:23380972

  13. Surface tension in human pathophysiology and its application as a medical diagnostic tool

    PubMed Central

    Fathi-Azarbayjani, Anahita; Jouyban, Abolghasem

    2015-01-01

    Introduction: Pathological features of disease appear to be quite different. Despite this diversity, the common feature of various disorders underlies physicochemical and biochemical factors such as surface tension. Human biological fluids comprise various proteins and phospholipids which are capable of adsorption at fluid interfaces and play a vital role in the physiological function of human organs. Surface tension of body fluids correlates directly to the development of pathological states. Methods: In this review, the variety of human diseases mediated by the surface tension changes of biological phenomena and the failure of biological fluids to remain in their native state are discussed. Results: Dynamic surface tension measurements of human biological fluids depend on various parameters such as sex, age and changes during pregnancy or certain disease. It is expected that studies of surface tension behavior of human biological fluids will provide additional information and might become useful in medical practice. Theoretical background on surface tension measurement and surface tension values of reference fluids obtained from healthy and sick patients are depicted. Conclusion: It is well accepted that no single biomarker will be effective in clinical diagnosis. The surface tension measurement combined with routine lab tests may be a novel non-invasive method which can not only facilitate the discovery of diagnostic models for various diseases and its severity, but also be a useful tool for monitoring treatment efficacy. We therefore expect that studies of surface tension behavior of human biological fluids will provide additional useful information in medical practice. PMID:25901295

  14. Fluid-structure interaction analysis of the flow through a stenotic aortic valve

    NASA Astrophysics Data System (ADS)

    Maleki, Hoda; Labrosse, Michel R.; Durand, Louis-Gilles; Kadem, Lyes

    2009-11-01

    In Europe and North America, aortic stenosis (AS) is the most frequent valvular heart disease and cardiovascular disease after systemic hypertension and coronary artery disease. Understanding blood flow through an aortic stenosis and developing new accurate non-invasive diagnostic parameters is, therefore, of primarily importance. However, simulating such flows is highly challenging. In this study, we considered the interaction between blood flow and the valve leaflets and compared the results obtained in healthy valves with stenotic ones. One effective method to model the interaction between the fluid and the structure is to use Arbitrary Lagrangian-Eulerian (ALE) approach. Our two-dimensional model includes appropriate nonlinear and anisotropic materials. It is loaded during the systolic phase by applying pressure curves to the fluid domain at the inflow. For modeling the calcified stenotic valve, calcium will be added on the aortic side of valve leaflets. Such simulations allow us to determine the effective orifice area of the valve, one of the main parameters used clinically to evaluate the severity of an AS, and to correlate it with changes in the structure of the leaflets.

  15. Review of Prospects of Biological Fluid Biomarkers in Osteoarthritis

    PubMed Central

    Nguyen, Lich Thi; Sharma, Ashish Ranjan; Chakraborty, Chiranjib; Saibaba, Balaji; Ahn, Moo-Eob; Lee, Sang-Soo

    2017-01-01

    Osteoarthritis (OA) is a degenerative disease of the joints and is one of the leading causes of disability in adults. However, there are no key therapeutics for OA and medical treatment is based on managing the symptoms and slowing down progression of the disease. Diagnostics based on clinical examination and radiography have provided little information about metabolic changes in joint tissues, disease onset and progression. Due to lack of effective methods for early detection and evaluation of treatment outcome, the measurement of biochemical markers (biomarkers) shows promise as a prospective method aiding in disease monitoring. OA biomarkers that are present in biological fluids such as blood, urine and synovial fluid, sources that are easily isolated from body, are of particular interest. Moreover, there are increasingly more studies identifying and developing new biomarkers for OA. In this review, efforts have been made to summarize the biomarkers that have been reported in recent studies on patients. We also tried to classify biomarkers according to tissue metabolism (bone, cartilage and synovial metabolism markers), pathological pathways (inflammatory and genetic markers) and biological function (chemokines, growth factors, acute phase proteins, etc.). PMID:28287489

  16. A novel method for a fast diagnosis of septic arthritis using mid infrared and deported spectroscopy.

    PubMed

    Albert, Jean-David; Monbet, Valérie; Jolivet-Gougeon, Anne; Fatih, Nadia; Le Corvec, Maëna; Seck, Malik; Charpentier, Frédéric; Coiffier, Guillaume; Boussard-Pledel, Catherine; Bureau, Bruno; Guggenbuhl, Pascal; Loréal, Olivier

    2016-05-01

    To assess the ability of mid infrared deported spectroscopy to discriminate synovial fluids samples of septic arthritis patients from other causes of joint effusion. Synovial fluids obtained from patients with clinically suspected arthritis were collected, analysed and classified according to standard diagnostic procedures as septic or non-septic. A spectroscopic analysis on synovial fluid samples was then performed using a coiled optical fiber made with chalcogenide glass. After a factorial analysis of the normalized spectra and the computation of a Fisher test used to select the most relevant components, a logistic regression model was fitted, allowing to attribute a score between 0 - non-septic -, and 1 - septic. In a first phase, we analysed the synovial fluids from 122 different synovial fluids including 6 septic arthritis among arthritis of various origins. Septic synovial fluids were identified with a sensitivity of 95.8% and a specificity of 93.9% and an AUROC of 0.977. The analysis of an independent set of samples (n=42, including two septic arthritis) gave similar values. Our data strongly supports the interest of mid infrared deported spectroscopy, which could be used potentially at point of care, for a rapid and easy diagnosis of septic arthritis. Now, the precision of the diagnosis must be evaluated through a multicentric study on a larger panel of patients. Copyright © 2015 Société française de rhumatologie. Published by Elsevier SAS. All rights reserved.

  17. Office hysteroscopy and adenomyosis.

    PubMed

    Molinas, Carlos Roger; Campo, Rudi

    2006-08-01

    Adenomyosis, the heterotopic presence of endometrial glands and stroma within the myometrium, has traditionally been diagnosed by the pathologist in hysterectomy specimens. However, the recent development of high-quality non-invasive techniques such as transvaginal sonography (TVS), magnetic resonance imaging (MRI) and hysteroscopy has renewed interest in diagnosing adenomyosis in the office prior to any treatment. Hysteroscopy offers the advantage of direct visualization of the uterine cavity, and since nowadays it is performed in the office, it can be offered as a first-line diagnostic tool for evaluation of uterine abnormalities in patients with abnormal uterine bleeding and/or infertility. The available data clearly indicate that high-quality mini-hysteroscopes, saline as a distension medium, and atraumatic insertion technique are essential for the success of office hysteroscopy. The procedure is indicated in any situation in which an intrauterine anomaly is suspected; it is immediately preceded by a physical exam and a TVS to evaluate uterine characteristics, and it is followed by a second TVS to take advantage of the intracavitary fluid for a contrast image of the uterus. Although diagnostic hysteroscopy does not provide pathognomonic signs for adenomyosis, some evidence suggests that irregular endometrium with endometrial defects, altered vascularization, and cystic haemorrhagic lesion are possibly associated with the entity. In addition to the direct visualization of the uterine cavity, the hysteroscopic approach offers the possibility of obtaining endometrial/myometrial biopsies under visual control. Since they can be performed in the office, the combination of TVS, fluid hysteroscopy and contrast sonography is therefore a powerful screening tool for detecting endometrial and myometrial abnormalities in association with adenomyosis.

  18. Evaluation of the aero-optical properties of the SOFIA cavity by means of computional fluid dynamics and a super fast diagnostic camera

    NASA Astrophysics Data System (ADS)

    Engfer, Christian; Pfüller, Enrico; Wiedemann, Manuel; Wolf, Jürgen; Lutz, Thorsten; Krämer, Ewald; Röser, Hans-Peter

    2012-09-01

    The Stratospheric Observatory for Infrared Astronomy (SOFIA) is a 2.5 m reflecting telescope housed in an open cavity on board of a Boeing 747SP. During observations, the cavity is exposed to transonic flow conditions. The oncoming boundary layer evolves into a free shear layer being responsible for optical aberrations and for aerodynamic and aeroacoustic disturbances within the cavity. While the aero-acoustical excitation of an airborne telescope can be minimized by using passive flow control devices, the aero-optical properties of the flow are difficult to improve. Hence it is important to know how much the image seen through the SOFIA telescope is perturbed by so called seeing effects. Prior to the SOFIA science fights Computational Fluid Dynamics (CFD) simulations using URANS and DES methods were carried out to determine the flow field within and above the cavity and hence in the optical path in order to provide an assessment of the aero-optical properties under baseline conditions. In addition and for validation purposes, out of focus images have been taken during flight with a Super Fast Diagnostic Camera (SFDC). Depending on the binning factor and the sub-array size, the SFDC is able to take and to read out images at very high frame rates. The paper explains the numerical approach based on CFD to evaluate the aero-optical properties of SOFIA. The CFD data is then compared to the high speed images taken by the SFDC during flight.

  19. Proposed diagnostic criteria for the case definition of amniotic fluid embolism in research studies

    PubMed Central

    Clark, Steven L.; Romero, Roberto; Dildy, Gary A.; Callaghan, William M.; Smiley, Richard M.; Bracey, Arthur W.; Hankins, Gary D.; D’Alton, Mary E.; Foley, Mike; Pacheco, Luis D.; Vadhera, Rakesh B.; Herlihy, J. Patrick; Berkowitz, Richard L.; Belfort, Michael A.

    2016-01-01

    Amniotic fluid embolism is a leading cause of maternal mortality in developed countries. Our understanding of risk factors, diagnosis, treatment, and prognosis is hampered by a lack of uniform clinical case definition; neither histologic nor laboratory findings have been identified unique to this condition. Amniotic fluid embolism is often overdiagnosed in critically ill peripartum women, particularly when an element of coagulopathy is involved. Previously proposed case definitions for amniotic fluid embolism are nonspecific, and when viewed through the eyes of individuals with experience in critical care obstetrics, would include women with a number of medical conditions much more common than amniotic fluid embolism. We convened a working group under the auspices of a committee of the Society for Maternal-Fetal Medicine and the Amniotic Fluid Embolism Foundation whose task was to develop uniform diagnostic criteria for the research reporting of amniotic fluid embolism. These criteria rely on the presence of the classic triad of hemodynamic and respiratory compromise accompanied by strictly defined disseminated intravascular coagulopathy. It is anticipated that limiting research reports involving amniotic fluid embolism to women who meet these criteria will enhance the validity of published data and assist in the identification of risk factors, effective treatments, and possibly useful biomarkers for this condition. A registry has been established in conjunction with the Perinatal Research Branch of the Eunice Kennedy Shriver National Institute of Child Health and Human Development to collect both clinical information and laboratory specimens of women with suspected amniotic fluid embolism in the hopes of identifying unique biomarkers of this condition. PMID:27372270

  20. Proposed diagnostic criteria for the case definition of amniotic fluid embolism in research studies.

    PubMed

    Clark, Steven L; Romero, Roberto; Dildy, Gary A; Callaghan, William M; Smiley, Richard M; Bracey, Arthur W; Hankins, Gary D; D'Alton, Mary E; Foley, Mike; Pacheco, Luis D; Vadhera, Rakesh B; Herlihy, J Patrick; Berkowitz, Richard L; Belfort, Michael A

    2016-10-01

    Amniotic fluid embolism is a leading cause of maternal mortality in developed countries. Our understanding of risk factors, diagnosis, treatment, and prognosis is hampered by a lack of uniform clinical case definition; neither histologic nor laboratory findings have been identified unique to this condition. Amniotic fluid embolism is often overdiagnosed in critically ill peripartum women, particularly when an element of coagulopathy is involved. Previously proposed case definitions for amniotic fluid embolism are nonspecific, and when viewed through the eyes of individuals with experience in critical care obstetrics, would include women with a number of medical conditions much more common than amniotic fluid embolism. We convened a working group under the auspices of a committee of the Society for Maternal-Fetal Medicine and the Amniotic Fluid Embolism Foundation whose task was to develop uniform diagnostic criteria for the research reporting of amniotic fluid embolism. These criteria rely on the presence of the classic triad of hemodynamic and respiratory compromise accompanied by strictly defined disseminated intravascular coagulopathy. It is anticipated that limiting research reports involving amniotic fluid embolism to women who meet these criteria will enhance the validity of published data and assist in the identification of risk factors, effective treatments, and possibly useful biomarkers for this condition. A registry has been established in conjunction with the Perinatal Research Branch of the Eunice Kennedy Shriver National Institute of Child Health and Human Development to collect both clinical information and laboratory specimens of women with suspected amniotic fluid embolism in the hopes of identifying unique biomarkers of this condition. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Bronchoalveolar Lavage Fluid Characteristics of Patients With Sarcoidosis and Nonsarcoidosis Interstitial Lung Diseases: Ten-Year Experience of a Single Center in Turkey

    PubMed Central

    Tanriverdi, Hakan; Erboy, Fatma; Altinsoy, Bulent; Uygur, Firat; Arasli, Mehmet; Ozel Tekin, Ishak; Tor, Muge Meltem; Atalay, Figen

    2015-01-01

    Background: Bronchoalveolar lavage (BAL) is a noninvasive and useful technique for evaluating interstitial lung diseases (ILDs). Flow cytometric analysis of BAL fluid reveals specific diagnostic information in some unusual ILDs, and helps to narrow down the possible causes of interstitial diseases in most patients with more common disorders. A high BAL CD4/CD8 ratio is highly specific for sarcoidosis but can also be seen in other ILDs. Objectives: In this retrospective, descriptive, cross-sectional study, we compared BAL fluid characteristics and clinical variables in patients with sarcoidosis and non-sarcoidosis ILDs in a large cohort. Patients and Methods: The study was conducted in a tertiary university hospital in Zonguldak, the biggest city of the western Black Sea region of Turkey. Between 2004 and 2014, all patients who underwent both fiberoptic bronchoscopy and BAL with a suspicion of ILD were included in the study, retrospectively. Patients were divided into two main groups: sarcoidosis and non-sarcoidosis ILDs. Non-sarcoidosis ILDs were further divided into subgroups: pneumoconiosis, tuberculosis (TB), collagen vascular diseases, idiopathic interstitial pneumonias, malignancies, and unclassified ILDs. The clinical data of patients, including age, gender, smoking status, pulmonary function tests, and BAL flow cytometric analysis results, were compared among groups. Results: In total, 261 patients (119 sarcoidosis and 142 non-sarcoidosis ILDs) were enrolled. The median (interquartile range) BAL CD4/CD8 ratio and lymphocyte fraction were significantly higher in sarcoidosis than in non-sarcoidosis ILDs: 3.88 (3.76) versus 0.88 (1.01), respectively, and 20.6 (28.3) versus 6.0 (13.7), respectively. T cell receptor γ delta, CD16+56+, CD103+, CD8+103+, and CD3+16+56+ cells were significantly lower in sarcoidosis than in non-sarcoidosis ILDs. The median BAL CD4/CD8 ratios were significantly higher in patients with TB (1.87, P = 0.01) and malignancies (1.69, P = 0.03) than in other non-sarcoidosis ILDs. Conclusions: Among BAL fluid flow cytometric parameters, CD4/CD8 and lymphocyte fraction may be helpful for distinguishing sarcoidosis from other ILDs, but they are neither specific nor diagnostic for any lung disease. Thus, a multidisciplinary diagnostic discussion is required to differentiate various ILDs. PMID:26566455

  2. Headspace screening of fluid obtained from the gut during colonoscopy and breath analysis by proton transfer reaction-mass spectrometry: A novel approach in the diagnosis of gastro-intestinal diseases

    NASA Astrophysics Data System (ADS)

    Lechner, M.; Colvin, H. P.; Ginzel, C.; Lirk, P.; Rieder, J.; Tilg, H.

    2005-05-01

    Background: The diagnosis of many gastro-intestinal diseases is difficult and can often be confirmed only by using invasive diagnostic means. In contrast, the headspace screening of fluid obtained from the gut during colonoscopy and the analysis of exhaled air may be a novel approach for the diagnosis of these diseases.Materials and methods: The screening was performed by using proton transfer reaction-mass spectrometry (PTR-MS) which allows rapid and sensitive measurement. Fluid samples obtained from the gut during colonoscopy were collected from 76 and breath samples from 70 subjects. Mass spectra of healthy controls were created. Afterwards these spectra were compared with those of patients suffering from inflammatory bowel diseases (IBD; Crohn's disease and ulcerative colitis; n = 10) and irritable bowel syndrome (IBS; n = 7).Results: Significant differences in the mass spectra could be observed both in the headspace of the fluid and in the exhaled air comparing patients with healthy controls.Conclusions: This study is the first describing headspace screening of fluid obtained from the gut during colonoscopy, possibly presenting a novel diagnostic tool in the differential diagnosis of gastro-intestinal diseases.

  3. MRI Features in a Canine Model of Ischemic Stroke: Correlation between Lesion Volume and Neurobehavioral Status during the Subacute Stage

    PubMed Central

    Kang, Byeong-Teck; Jang, Dong-Pyo; Gu, Su-Hyun; Lee, Jong-Hwan; Jung, Dong-In; Lim, Chae-Young; Kim, Ha-Jung; Kim, Young-Bo; Kim, Hyung-Joong; Woo, Eung-Je; Cho, Zang-Hee; Park, Hee-Myung

    2009-01-01

    The purpose of this study was to evaluate the diagnostic value of magnetic resonance imaging (MRI) and assess the correlation between the volume of the ischemic lesion and neurobehavioral status during the subacute stage of ischemic stroke. Ischemic stroke was induced in 6 healthy laboratory beagles through permanent occlusion of the middle cerebral artery (MCAO). T2-weighted and fluid-attenuated inversion recovery (FLAIR) imaging, diffusion-weighted imaging (DWI), measurement of the apparent diffusion coefficient (ADC) ratio, and neurobehavioral evaluation were performed 3 times serially by using a 1.5-T MR system: before and 3 and 10 d after MCAO. Ischemic lesions demonstrated T2 hyperintensity, FLAIR hyperintensity, and DWI hyperintensity. The ADC ratio was decreased initially but then was increased at 10 d after MCAO. Ischemic lesion volumes on T2-weighted and FLAIR imaging were not significantly different from those on DWI. The lesion volume and neurobehavioral score showed strong correlation. Our results suggest that conventional MRI may be a reliable diagnostic tool during the subacute stage of canine ischemic stroke. PMID:19887030

  4. Indications for endoscopic third ventriculostomy in normal pressure hydrocephalus.

    PubMed

    Paidakakos, Nikolaos; Borgarello, S; Naddeo, M

    2012-01-01

    Controversies remain regarding the proper diagnostic studies and prediction of outcome in patients with normal pressure hydrocephalus (NPH), and their management remains controversial. We propose a preoperative assessment routine the aim of which is to correctly select NPH patients, and to differentiate between them in terms of surgical treatment, identifying probable endoscopic third ventriculostomy (ETV) responders. We prospectively considered a group of 44 patients with suspected NPH on the basis of clinical symptoms and neuroradiological evidence, who have undergone supplemental diagnostic testing (tap test, external lumbar drainage, cerebrospinal fluid outflow resistance [Rout] determination through lumbar and ventricular infusion test). All 44 of these patients were treated with either shunt procedures or ETV. To choose the kind of treatment (shunt or ETV), we evaluated the individual response during infusion tests. The efficacy of both surgical techniques was approximately 70%, with a significantly lower complication rate for ETV. We evaluated the correlation between the various tests and the postoperative outcomes both for shunting and for ETV. Rout proved useful for preoperative assessment and choice of treatment. In carefully selected patients, ETV had qualitative results similar to shunting, presenting significantly fewer complications.

  5. Sweat lipid mediator profiling: a non-invasive approach for cutaneous research

    USDA-ARS?s Scientific Manuscript database

    Sweat is a complex biological fluid with potential diagnostic value for the investigation of skin disorders. Previous efforts in sweat testing focused on analysis of small molecules and ions for forensic and diagnostic testing, but with advances in analytical and sweat collection techniques, there h...

  6. Gross Brain Morphology in Schizophrenia: A Regional Analysis of Traditional Diagnostic Subtypes.

    ERIC Educational Resources Information Center

    Raz, Sarah

    1994-01-01

    Categorized 56 patients with chronic schizophrenia into 2 groups based on traditional diagnostic subtypology. Compared groups on indices of cortical and subcortical cerebrospinal fluid (SCF) volume to explore whether more virulent nonparanoid disorder was linked to cortical/subcortical morphological brain abnormalities. Two groups differed…

  7. Circulating microparticles: square the circle

    PubMed Central

    2013-01-01

    Background The present review summarizes current knowledge about microparticles (MPs) and provides a systematic overview of last 20 years of research on circulating MPs, with particular focus on their clinical relevance. Results MPs are a heterogeneous population of cell-derived vesicles, with sizes ranging between 50 and 1000 nm. MPs are capable of transferring peptides, proteins, lipid components, microRNA, mRNA, and DNA from one cell to another without direct cell-to-cell contact. Growing evidence suggests that MPs present in peripheral blood and body fluids contribute to the development and progression of cancer, and are of pathophysiological relevance for autoimmune, inflammatory, infectious, cardiovascular, hematological, and other diseases. MPs have large diagnostic potential as biomarkers; however, due to current technological limitations in purification of MPs and an absence of standardized methods of MP detection, challenges remain in validating the potential of MPs as a non-invasive and early diagnostic platform. Conclusions Improvements in the effective deciphering of MP molecular signatures will be critical not only for diagnostics, but also for the evaluation of treatment regimens and predicting disease outcomes. PMID:23607880

  8. Development of a diagnostic real-time polymerase chain reaction assay for the detection of invasive Haemophilus influenzae in clinical samples.

    PubMed

    Meyler, Kenneth L; Meehan, Mary; Bennett, Desiree; Cunney, Robert; Cafferkey, Mary

    2012-12-01

    Since the introduction of the Haemophilus influenzae serotype b vaccine, invasive H. influenzae disease has become dominated by nontypeable (NT) strains. Several widely used molecular diagnostic methods have been shown to lack sensitivity or specificity in the detection of some of these strains. Novel real-time assays targeting the fucK, licA, and ompP2 genes were developed and evaluated. The fucK assay detected all strains of H. influenzae tested (n = 116) and had an analytical sensitivity of 10 genome copies/polymerase chain reaction (PCR). This assay detected both serotype b and NT H. influenzae in 12 previously positive specimens (culture and/or bexA PCR) and also detected H. influenzae in a further 5 of 883 culture-negative blood and cerebrospinal fluid (CSF) samples. The fucK assay has excellent potential as a diagnostic test for detection of typeable and nontypeable strains of invasive H. influenzae in clinical samples of blood and CSF. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. Cerebrospinal fluid myelin basic protein is frequently ordered but has little value: a test utilization study.

    PubMed

    Greene, Dina N; Schmidt, Robert L; Wilson, Andrew R; Freedman, Mark S; Grenache, David G

    2012-08-01

    Diagnosis of multiple sclerosis (MS) is facilitated by analyzing biochemical properties of cerebrospinal fluid (CSF). Oligoclonal bands (OCBs) and immunoglobulin G (IgG) index are well-established markers for evaluating patients suspected of having MS. Myelin basic protein (MBP) is also ordered frequently, but its usefulness remains questionable. OCB, IgG index, and MBP were measured in 16,690 consecutive CSF samples. Samples were divided into 2 groups based on MS status known (n = 71) or unknown (n = 16,118). Medical charts of the MS status known group were reviewed to determine their MS status. OCBs have a stronger association to IgG index results than does MBP. Importantly, MBP does not add a statistically significant increase in diagnostic sensitivity or specificity when used in combination with OCB and/or IgG index. The data indicate that MBP is an unnecessary and overused test.

  10. [Quantitative Evaluation of Intracardiac Blood Flow by Left Ventricle Dynamic Anatovy Based On Exact Solutions of Non-Stationary Navier-Stocks Equations for Selforganized tornado-Like Flows of Viscous Incompresssible Fluid].

    PubMed

    Talygin, E A; Zazybo, N A; Zhorzholiany, S T; Krestinich, I M; Mironov, A A; Kiknadze, G I; Bokerya, L A; Gorodkov, A Y; Makarenko, V N; Alexandrova, S A

    2016-01-01

    New approach to intracardiac blood flow condition analysis based on geometric parameters of left ventricle flow channel has been suggested. Parameters, that used in this method, follow from exact solutions of nonstationary Navier-Stocks equations for selforganized tornado-like flows of viscous incompressible fluid. The main advantage of this method is considering dynamic anatomy of intracardiac cavity and trabeculae relief of left ventricle streamlined surface, both registered in a common mri-process, as flow condition indicator. Calculated quantity options that characterizes blood flow condition can be use as diagnostic criterias for estimation of violation in blood circulation function which entails heart ejection reduction. Developed approach allows to clarify heart jet organization mechanism and estimate the share of the tornado-like flow self-organization in heart ejection structure.

  11. Seroprevalence of toxoplasmosis in Korean pregnant women.

    PubMed

    Song, Kyoung-Ju; Shin, Jong-Chul; Shin, Ho-Joon; Nam, Ho-Woo

    2005-06-01

    This study was performed in order to evaluate the sero-epidemiological status of toxoplasmosis in pregnant Korean women. Among 5,175 sera and 750 amniotic fluid samples obtained from pregnant women, 41 serum samples (0.79%) and 10 (1.33%) amniotic fluid samples tested positive for IgG antibodies by ELISA. Fifty one cases showing a score more than 0.25 on ELISA were tested for PCR reaction against the SAG1 gene. Only one case of the 51 ELISA positive cases exhibited a positive reaction on all tests. This case had a history of acute nephropyelitis during early pregnancy, but fortunately, had delivered a phenotypically healthy baby. In this study, the seroprevalence of toxoplasmosis in pregnant women was found to be comparatively low, consistent with previous reports from Korea. However our trials, performed with a variety of diagnostic tools, were considered to be useful for the precise diagnosis of congenital toxoplasmosis.

  12. Brain-Specific Cytoskeletal Damage Markers in Cerebrospinal Fluid: Is There a Common Pattern between Amyotrophic Lateral Sclerosis and Primary Progressive Multiple Sclerosis?

    PubMed

    Abdelhak, Ahmed; Junker, Andreas; Brettschneider, Johannes; Kassubek, Jan; Ludolph, Albert C; Otto, Markus; Tumani, Hayrettin

    2015-07-31

    Many neurodegenerative disorders share a common pathophysiological pathway involving axonal degeneration despite different etiological triggers. Analysis of cytoskeletal markers such as neurofilaments, protein tau and tubulin in cerebrospinal fluid (CSF) may be a useful approach to detect the process of axonal damage and its severity during disease course. In this article, we review the published literature regarding brain-specific CSF markers for cytoskeletal damage in primary progressive multiple sclerosis and amyotrophic lateral sclerosis in order to evaluate their utility as a biomarker for disease progression in conjunction with imaging and histological markers which might also be useful in other neurodegenerative diseases associated with affection of the upper motor neurons. A long-term benefit of such an approach could be facilitating early diagnostic and prognostic tools and assessment of treatment efficacy of disease modifying drugs.

  13. Brain-Specific Cytoskeletal Damage Markers in Cerebrospinal Fluid: Is There a Common Pattern between Amyotrophic Lateral Sclerosis and Primary Progressive Multiple Sclerosis?

    PubMed Central

    Abdelhak, Ahmed; Junker, Andreas; Brettschneider, Johannes; Kassubek, Jan; Ludolph, Albert C.; Otto, Markus; Tumani, Hayrettin

    2015-01-01

    Many neurodegenerative disorders share a common pathophysiological pathway involving axonal degeneration despite different etiological triggers. Analysis of cytoskeletal markers such as neurofilaments, protein tau and tubulin in cerebrospinal fluid (CSF) may be a useful approach to detect the process of axonal damage and its severity during disease course. In this article, we review the published literature regarding brain-specific CSF markers for cytoskeletal damage in primary progressive multiple sclerosis and amyotrophic lateral sclerosis in order to evaluate their utility as a biomarker for disease progression in conjunction with imaging and histological markers which might also be useful in other neurodegenerative diseases associated with affection of the upper motor neurons. A long-term benefit of such an approach could be facilitating early diagnostic and prognostic tools and assessment of treatment efficacy of disease modifying drugs. PMID:26263977

  14. Clinical relevance of pulse pressure variations for predicting fluid responsiveness in mechanically ventilated intensive care unit patients: the grey zone approach.

    PubMed

    Biais, Matthieu; Ehrmann, Stephan; Mari, Arnaud; Conte, Benjamin; Mahjoub, Yazine; Desebbe, Olivier; Pottecher, Julien; Lakhal, Karim; Benzekri-Lefevre, Dalila; Molinari, Nicolas; Boulain, Thierry; Lefrant, Jean-Yves; Muller, Laurent

    2014-11-04

    Pulse pressure variation (PPV) has been shown to predict fluid responsiveness in ventilated intensive care unit (ICU) patients. The present study was aimed at assessing the diagnostic accuracy of PPV for prediction of fluid responsiveness by using the grey zone approach in a large population. The study pooled data of 556 patients from nine French ICUs. Hemodynamic (PPV, central venous pressure (CVP) and cardiac output) and ventilator variables were recorded. Responders were defined as patients increasing their stroke volume more than or equal to 15% after fluid challenge. The receiver operating characteristic (ROC) curve and grey zone were defined for PPV. The grey zone was evaluated according to the risk of fluid infusion in hypoxemic patients. Fluid challenge led to increased stroke volume more than or equal to 15% in 267 patients (48%). The areas under the ROC curve of PPV and CVP were 0.73 (95% confidence interval (CI): 0.68 to 0.77) and 0.64 (95% CI 0.59 to 0.70), respectively (P<0.001). A grey zone of 4 to 17% (62% of patients) was found for PPV. A tidal volume more than or equal to 8 ml.kg(-1) and a driving pressure (plateau pressure - PEEP) more than 20 cmH2O significantly improved the area under the ROC curve for PPV. When taking into account the risk of fluid infusion, the grey zone for PPV was 2 to 13%. In ventilated ICU patients, PPV values between 4 and 17%, encountered in 62% patients exhibiting validity prerequisites, did not predict fluid responsiveness.

  15. The history of imaging in obstetrics.

    PubMed

    Benson, Carol B; Doubilet, Peter M

    2014-11-01

    During the past century, imaging of the pregnant patient has been performed with radiography, scintigraphy, computed tomography, magnetic resonance imaging, and ultrasonography (US). US imaging has emerged as the primary imaging modality, because it provides real-time images at relatively low cost without the use of ionizing radiation. This review begins with a discussion of the history and current status of imaging modalities other than US for the pregnant patient. The discussion then turns to an in-depth description of how US technology advanced to become such a valuable diagnostic tool in the obstetric patient. Finally, the broad range of diagnostic uses of US in these patients is presented, including its uses for distinguishing an intrauterine pregnancy from a failed or ectopic pregnancy in the first trimester; assigning gestational age and assessing fetal weight; evaluating the fetus for anomalies and aneuploidy; examining the uterus, cervix, placenta, and amniotic fluid; and guiding obstetric interventional procedures.

  16. Rabies in the critical care unit: diagnostic and therapeutic approaches.

    PubMed

    Jackson, Alan C

    2011-09-01

    Worldwide, human rabies is prevalent where there is endemic dog rabies, but the disease may present unexpectedly in critical care units when suggestive clinical features have passed. In North America transmission from bats is most common and there is often no history of a bat bite or even contact with bats. Laboratory diagnostic evaluation for rabies includes serology plus skin biopsy, cerebrospinal fluid, and saliva specimens for rabies virus antigen and/or RNA detection. Rare patients have survived rabies, and most received rabies vaccine prior to the onset of illness. Therapeutic coma (midazolam and phenobarbital), ketamine, and antiviral therapies (dubbed the "Milwaukee Protocol") were given to a rabies survivor, but this therapy was likely not directly responsible for the favorable outcome. There have been many subsequent failures of similar therapeutic approaches. There is no scientific rationale for the use of therapeutic coma in human rabies. New approaches to treating human rabies need to be developed.

  17. Portable Medical Diagnosis Instrument

    NASA Technical Reports Server (NTRS)

    Coleman, Matthew A. (Inventor); Straume, Tore (Inventor); Loftus, David J. (Inventor); Li, Jing (Inventor); Singh, Anup K. (Inventor); Davis, Cristina E. (Inventor)

    2017-01-01

    A system that integrates several technologies into a single, portable medical diagnostic apparatus for analyzing a sample body fluid (liquid and/or gas): (1) a mechanism to capture airborne microdroplets and to separate the body fluid into a first fluid component (primarily gas) and a second fluid component (primarily liquid); (2) a volatilizer to convert a portion of the second fluid component into a third fluid component that is primarily a gas; (3) a functionalized nanostructure (NS) array configured to receive, identify, and estimate concentration of at least one constituent in the first and/or third fluid components; (4) a miniaturized differential mobility spectrometer (DMS) module; and (5) a biomarker sensor, to detect volatile and non-volatile molecules in a sample fluid, which may contain one or more components of blood, breath, perspiration, saliva, and urine.

  18. Amniotic fluid embolism: diagnosis and management.

    PubMed

    Pacheco, Luis D; Saade, George; Hankins, Gary D V; Clark, Steven L

    2016-08-01

    We sought to provide evidence-based guidelines regarding the diagnosis and management of amniotic fluid embolism. A systematic literature review was performed using MEDLINE, PubMed, EMBASE, and the Cochrane Library. The search was restricted to English-language articles published from 1966 through March 2015. Priority was given to articles reporting original research, in particular randomized controlled trials, although review articles and commentaries were consulted. Abstracts of research presented at symposia and scientific conferences were not considered adequate for inclusion. Evidence reports and published guidelines were also reviewed, and additional studies were located by reviewing bibliographies of identified articles. Grading of Recommendations Assessment, Development, and Evaluation (GRADE) methodology was used for defining the strength of recommendations and rating quality of the evidence. Consistent with US Preventive Task Force guidelines, references were evaluated for quality based on the highest level of evidence. We recommend the following: (1) we recommend consideration of amniotic fluid embolism in the differential diagnosis of sudden cardiorespiratory collapse in the laboring or recently delivered woman (GRADE 1C); (2) we do not recommend the use of any specific diagnostic laboratory test to either confirm or refute the diagnosis of amniotic fluid embolism; at the present time, amniotic fluid embolism remains a clinical diagnosis (GRADE 1C); (3) we recommend the provision of immediate high-quality cardiopulmonary resuscitation with standard basic cardiac life support and advanced cardiac life support protocols in patients who develop cardiac arrest associated with amniotic fluid embolism (GRADE 1C); (4) we recommend that a multidisciplinary team including anesthesia, respiratory therapy, critical care, and maternal-fetal medicine should be involved in the ongoing care of women with AFE (Best Practice); (5) following cardiac arrest with amniotic fluid embolism, we recommend immediate delivery in the presence of a fetus ≥23 weeks of gestation (GRADE 2C); (6) we recommend the provision of adequate oxygenation and ventilation and, when indicated by hemodynamic status, the use of vasopressors and inotropic agents in the initial management of amniotic fluid embolism. Excessive fluid administration should be avoided (GRADE 1C); and (7) because coagulopathy may follow cardiovascular collapse with amniotic fluid embolism, we recommend the early assessment of clotting status and early aggressive management of clinical bleeding with standard massive transfusion protocols (GRADE 1C). Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Reliability of Urinary Dehydration Markers in Elite Youth Boxers.

    PubMed

    Zubac, Damir; Cular, Drazen; Marusic, Uros

    2018-03-01

    To determine the reliability and diagnostic accuracy of noninvasive urinary dehydration markers in field-based settings on a day-to-day basis in elite adolescent amateur boxers. Sixty-nine urine samples were collected daily from 23 athletes (17.3 ± 1.9 y) during their weight-stable phase and analyzed by field and laboratory measures of hydration status. Urine osmolality (U OSM ), urine specific gravity (U SG ), total protein content (T PC ), and body-mass stability were evaluated to determine fluid balance and hydration status. Overall macronutrient and water intake were determined using dietary records. According to their anthropometric characteristics, athletes were assigned into 2 groups: lightweight (L WB ) and heavyweight (H WB ) boxers. Data presented on U OSM demonstrated a uniform increment by 11.2% ± 12.8% (L WB ) and 19.9% ± 22.7% (H WB ) (P < .001) over the course of the study, even during the weight-stable phase (body mass, ICC = .99) and ad libitum fluid intake (42 ± 4 mL · kg -1  · d -1 ). The intraclass correlation coefficients (ICCs) ranged from .52 to .55 for U SG and .38 to .52 for U OSM , further indicating inconsistency of the urinary dehydration markers. Poor correlations were found between U SG and T PC metabolites (r = .27, P = .211). Urinary dehydration markers (both U SG and U OSM ) exhibit high variability and seem to be unreliable diagnostic tools to track actual body-weight loss in real-life settings. The ad libitum fluid intake was apparently inadequate to match acute fluid loss during and after intense preparation. The applicability of a single-time-point hydration-status assessment concept may preclude accurate assessment of actual body-weight deficits in youth boxers.

  20. Preoperative easily misdiagnosed telangiectatic osteosarcoma: clinical–radiologic–pathologic correlations

    PubMed Central

    Gao, Zhen-Hua; Yin, Jun-Qiang; Liu, Da-Wei; Meng, Quan-Fei

    2013-01-01

    Abstract Purpose: To describe the clinical, imaging, and pathologic characteristics and diagnostic methods of telangiectatic osteosarcoma (TOS) for improving the diagnostic level. Materials and methods: The authors retrospectively reviewed patient demographics, serum alkaline phosphatase (AKP) levels, preoperative biopsy pathologic reports, pathologic materials, imaging findings, and treatment outcomes from 26 patients with TOS. Patient images from radiography (26 cases) and magnetic resonance (MR) imaging (22 cases) were evaluated by 3 authors in consensus for intrinsic characteristics. There were 15 male and 11 female patients in the study, with an age of 9–32 years (mean age 15.9 years). Results: Eighteen of 26 patients died of lung metastases within 5 years of follow-up. The distal femur was affected more commonly (14 cases, 53.8%). Regarding serum AKP, normal (8 cases) or mildly elevated (18 cases) levels were found before preoperative chemotherapy. Radiographs showed geographic bone lysis without sclerotic margin (26 cases), cortical destruction (26 cases), periosteal new bone formation (24 cases), soft-tissue mass (23 cases), and matrix mineralization (4 cases). The aggressive radiographic features of TOS simulated the appearance of conventional high-grade intramedullary osteosarcoma, though different from aneurysmal bone cyst. MR images demonstrated multiple big (16 cases) or small (6 cases) cystic spaces, fluid-fluid levels (14 cases), soft-tissue mass (22 cases), and thick peripheral and septal enhancement (22 cases). Nine of 26 cases were misdiagnosed as aneurysmal bone cysts by preoperative core-needle biopsy, owing to the absence of viable high-grade sarcomatous cells in the small tissue samples. Conclusion: The aggressive growth pattern with occasional matrix mineralization, and multiple big or small fluid-filled cavities with thick peripheral, septal, and nodular tissue surrounding the fluid-filled cavities are characteristic imaging features of TOS, and these features are helpful in making the correct preoperative diagnosis of TOS. PMID:24334494

  1. Decreased synovial fluid ghrelin levels are linked with disease severity in primary knee osteoarthritis patients and are increased following laser therapy.

    PubMed

    Zou, Yu-Cong; Deng, Hong-Yu; Mao, Zheng; Zhao, Chang; Huang, Ju; Liu, Gang

    2017-07-01

    Ghrelin has been proved to inhibit inflammation and promote cartilage growth. So far, its role in patients with primary knee osteoarthritis has not been investigated. The current study was performed to explore the serum and synovial ghrelin levels as well as the relationship between ghrelin levels and disease severity in primary knee OA patients. 52 primary knee OA patients were recruited in the study. 52 sex and age-matched patients visiting our hospital for regular body check were selected as controls. The serum and synovial fluid ghrelin levels were examined by enzyme linked immunosorbent assay (ELISA) before treatment, one week and four weeks after laser therapy, respectively. The inflammation markers IL-6 and TNF-α were also investigated. The radiographic progression was assessed by Kellgren-Lawrence (K-L) grade scale and the symptomatic severity was evaluated by visual analog scale (VAS), Lequesne index and Lysholm scores. The Receiver Operating Characteristic (ROC) analysis curve was conducted to test the diagnostic value of ghrelin, IL-6 and TNF-α for radiographic progression. No significant difference of serum ghrelin levels was found between knee OA patients and healthy controls. Synovial fluid ghrelin concentrations were significantly negatively correlated with K-L grading (r=-0.591, P<0.001).Attenuated synovial fluid ghrelin levels were also related to clinical severity determined by Lequesne index (r=-0.308, P=0.025),VAS scores (r=-0.591, P<0.001) and Lysholm scores (r=0.381, P=0.005).In addition, ghrelin levels were also negatively associated with TNF-α (r=-0.424, P=0.002) and IL-6 concentrations (r=-0.428, P=0.002). ROC curve analysis demonstrated that ghrelin exhibited more diagnostic value than IL-6 and TNF-α for assessing radiographic progression in medium-late stage. Decreased synovial fluid ghrelin levels are related to disease severity in patients with primary osteoarthritis and are increased following laser therapy. Local application of ghrelin may serve as an adjunctive therapy for knee OA. Copyright © 2017. Published by Elsevier B.V.

  2. Gas chromatography-mass spectrometry-based metabolic profiling of cerebrospinal fluid from epileptic dogs.

    PubMed

    Hasegawa, Tetsuya; Sumita, Maho; Horitani, Yusuke; Tamai, Reo; Tanaka, Katsuhiro; Komori, Masayuki; Takenaka, Shigeo

    2014-04-01

    Epilepsy is a common neurological disorder with seizures, but diagnostic approaches in veterinary clinics remain limited. Cerebrospinal fluid (CSF) is a body fluid used for diagnosis in veterinary medicine. In this study, we explored canine epilepsy diagnostic biomarkers using gas chromatography-mass spectrometry (GC-MS)-based metabolic profiling of CSF and multivariate data analysis. Profiles for subjects with idiopathic epilepsy differed significantly from those of healthy controls and subjects with symptomatic epilepsy. Among 60 identified metabolites, the levels of 20 differed significantly among the three groups. Glutamic acid was significantly increased in idiopathic epilepsy, and some metabolites including ascorbic acid were changed in both forms of epilepsy. These findings show that metabolic profiles of CSF differ between idiopathic and symptomatic epilepsy and that metabolites including glutamic acid and ascorbic acid in CSF may be useful for diagnosis of canine epilepsy.

  3. Reprint of "EXOSOME LEVELS IN HUMAN BODY FLUIDS: A TUMOR MARKER BY THEMSELVES?"

    PubMed

    Cappello, Francesco; Logozzi, Mariantonia; Campanella, Claudia; Bavisotto, Celeste Caruso; Marcilla, Antonio; Properzi, Francesca; Fais, Stefano

    2017-02-15

    Despite considerable research efforts, the finding of reliable tumor biomarkers remains challenging and unresolved. In recent years a novel diagnostic biomedical tool with high potential has been identified in extracellular nanovesicles or exosomes. They are released by the majority of the cells and contain detailed molecular information on the cell of origin including tumor hallmarks. Exosomes can be isolated from easy accessible body fluids, and most importantly, they can at once provide with several biomarkers, with different levels of specificity. Recent clinical evidence shows that the levels of exosomes released into body fluids may by themselves represent a predictive/diagnostic of tumors, discriminating cancer patients from healthy subjects. The aim of this review is to highlight these latest challenging findings to provide novel and groundbreaking ideas for successful tumor early diagnosis and follow-up. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Apparatus for testing high pressure injector elements

    NASA Technical Reports Server (NTRS)

    Myers, William Neill (Inventor); Scott, Ewell M. (Inventor); Forbes, John C. (Inventor); Shadoan, Michael D. (Inventor)

    1995-01-01

    An apparatus for testing and evaluating the spray pattern of high pressure fuel injector elements for use in supplying fuel to combustion engines is presented. Prior art fuel injector elements were normally tested by use of low pressure apparatuses which did not provide a purge to prevent mist from obscuring the injector element or to prevent frosting of the view windows; could utilize only one fluid during each test; and had their viewing ports positioned one hundred eighty (180 deg) apart, thus preventing optimum use of laser diagnostics. The high pressure fluid injector test apparatus includes an upper hub, an upper weldment or housing, a first clamp and stud/nut assembly for securing the upper hub to the upper weldment, a standoff assembly within the upper weldment, a pair of window housings having view glasses within the upper weldment, an injector block assembly and purge plate within the upper weldment for holding an injector element to be tested and evaluated, a lower weldment or housing, a second clamp and stud/nut assembly for securing the lower weldment to the upper hub, a third clamp and stud/nut assembly for securing the lower hub to the lower weldment, mechanisms for introducing fluid under high pressure for testing an injector element, and mechanisms for purging the apparatus to prevent frosting of view glasses within the window housings and to permit unobstructed viewing of the injector element.

  5. Apparatus for testing high pressure injector elements

    NASA Technical Reports Server (NTRS)

    Myers, William Neill (Inventor); Scott, Ewell M. (Inventor); Forbes, John C. (Inventor); Shadoan, Michael D. (Inventor)

    1993-01-01

    An apparatus for testing and evaluating the spray pattern of high pressure fuel injector elements for use in supplying fuel to combustion engines is presented. Prior art fuel injector elements were normally tested by use of low pressure apparatuses which did not provide a purge to prevent mist from obscuring the injector element or to prevent frosting of the view windows; could utilize only one fluid during each test; and had their viewing ports positioned one hundred eighty (180 deg) apart, thus preventing optimum use of laser diagnostics. The high pressure fluid injector test apparatus includes an upper hub, an upper weldment or housing, a first clamp and stud/nut assembly for securing the upper hub to the upper weldment, a standoff assembly within the upper weldment, a pair of window housings having view glasses within the upper weldment, an injector block assembly and purge plate within the upper weldment for holding an injector element to be tested and evaluated, a lower weldment or housing, a second clamp and stud/nut assembly for securing the lower weldment to the upper weldment, a lower hub, a third clamp and stud/nut assembly for securing the lower hub to the lower weldment, mechanisms for introducing fluid under high pressure for testing an injector element, and mechanisms for purging the apparatus to prevent frosting of view glasses within the window housings and to permit unobstructed viewing of the injector element.

  6. Moderately nonlinear ultrasound propagation in blood-mimicking fluid.

    PubMed

    Kharin, Nikolay A; Vince, D Geoffrey

    2004-04-01

    In medical diagnostic ultrasound (US), higher than-in-water nonlinearity of body fluids and tissue usually does not produce strong nonlinearly distorted waves because of the high absorption. The relative influence of absorption and nonlinearity can be characterized by the Gol'dberg number Gamma. There are two limiting cases in nonlinear acoustics: weak waves (Gamma < 1) or strong waves (Gamma > 1). However, at diagnostic frequencies in tissue and body fluids, the nonlinear effects and effects of absorption more likely are comparable (Gol'dberg number Gamma approximately 1). The aim of this work was to study the nonlinear propagation of a moderately nonlinear US second harmonic signal in a blood-mimicking fluid. Quasilinear solutions to the KZK equation are presented, assuming radiation from a flat and geometrically focused circular Gaussian source. The solutions are expressed in a new simplified closed form and are in very good agreement with those of previous studies measuring and modeling Gaussian beams. The solutions also show good agreement with the measurements of the beams produced by commercially available transducers, even without special Gaussian shading.

  7. Presumed lupus erythematosus cells identified in bronchoalveolar lavage fluid from a Mexican Hairless dog.

    PubMed

    Black, Laura J; Hechler, Ashley C; Duffy, Maura E; Beatty, Sarah S K

    2017-06-01

    A neutered male Mexican Hairless dog was presented for generalized weight loss and weakness. Initial laboratory testing and diagnostic imaging revealed thrombocytopenia and an interstitial to miliary lung pattern affecting all lung fields. Mild joint effusion was found on physical examination affecting the stifle, tarsal, carpal, and elbow joints. Examination of synovial fluid demonstrated an inflammatory polyarthropathy in 3 joints. Cytocentrifuged and direct preparations of the bronchoalveolar lavage (BAL) fluid sample were made and cells consistent with lupus erythematosus (LE) cells and ragocytes were found. Based on these findings, the anti-nuclear antibody (ANA) titer was determined as 1:640. A clinical diagnosis of systemic LE was made based on the satisfaction of 2 major criteria (thrombocytopenia and inflammatory polyarthritis), 4 minor criteria (central nervous system signs, lymphadenopathy, fever of unknown origin, and pleuritis), positive ANA titer, and the identification of presumed LE cells in BAL fluid. This case report highlights a novel finding of LE cells in respiratory secretions and provides a review of diagnostic criteria of systemic LE. © 2017 American Society for Veterinary Clinical Pathology.

  8. Diagnostic Challenges of Central Nervous System Tuberculosis

    PubMed Central

    Loeffler, Ann M.; Honarmand, Somayeh; Flood, Jennifer M.; Baxter, Roger; Jacobson, Susan; Alexander, Rick; Glaser, Carol A.

    2008-01-01

    Central nervous system tuberculosis (TB) was identified in 20 cases of unexplained encephalitis referred to the California Encephalitis Project. Atypical features (encephalitic symptoms, rapid onset, age) and diagnostic challenges (insensitive cerebrospinal fluid [CSF] TB PCR result, elevated CSF glucose levels in patients with diabetes, negative result for tuberculin skin test) complicated diagnosis. PMID:18760024

  9. A Prospective Randomized Study Comparing Manual and Wall Suction in the Performance of Bronchoalveolar Lavage.

    PubMed

    Seijo, Luis M; Flandes, Javier; Somiedo, Maria V; Naya, Alba; Manjón, Josefina; Álvarez, Susana; Fernández-Navamuel, Iker

    2016-01-01

    Bronchoalveolar lavage (BAL) may be performed using a hand-held syringe or wall suction. The aim was to study BAL volume and diagnostic yields based on BAL technique. A total of 220 consecutive patients undergoing BAL at our center were included. Manual aspiration was performed in 115 patients (group 1), and wall suction (<50 mm Hg of negative pressure) was used in 105 patients (group 2). All bronchoscopies were performed under conscious sedation applying topical anesthesia with lidocaine. Three 50-ml sterile saline aliquots were instilled in all patients. The mean total amount of fluid recovered was 67 ± 20 ml in group 1 and 55 ± 22 ml in group 2 (p < 0.001). More patients in the manual aspiration group met American Thoracic Society criteria (recovery of ≥30% of instilled fluid) for an optimal BAL (81 vs. 59%; p < 0.001). The quantity of recovered fluid was also related to BAL location (p < 0.001) and radiologic findings (p = 0.002). Forty-eight (22%) BALs were diagnostic (23 in group 1 and 25 in group 2), including 37 positive bacterial cultures, 6 positive stains for Pneumocystis, and 5 cases of malignancy. No statistically significant difference in diagnostic yield was observed between the two groups. A BAL diagnosis was more likely in patients with certain radiologic (p = 0.033) and endoscopic findings (p = 0.001). When taking into account all bronchoscopic techniques performed during the procedure (e.g. biopsies, brushing, etc.), bronchoscopy was diagnostic in 37% of patients. Manual aspiration is superior to wall suction during BAL yielding a larger quantity of aspirate. Diagnostic yields are similar for both techniques. © 2016 S. Karger AG, Basel.

  10. Mixing in the Extratropical Stratosphere: Model-measurements Comparisons using MLM Diagnostics

    NASA Technical Reports Server (NTRS)

    Ma, Jun; Waugh, Darryn W.; Douglass, Anne R.; Kawa, Stephan R.; Bhartia, P. K. (Technical Monitor)

    2001-01-01

    We evaluate transport processes in the extratropical lower stratosphere for both models and measurements with the help of equivalent length diagnostic from the modified Lagrangian-mean (MLM) analysis. This diagnostic is used to compare measurements of long-lived tracers made by the Cryogenic Limb Array Etalon Spectrometer (CLAES) on the Upper Atmosphere Research Satellite (UARS) with simulated tracers. Simulations are produced in Chemical and Transport Models (CTMs), in which meteorological fields are taken from the Goddard Earth Observing System Data Assimilation System (GEOS DAS), the Middle Atmosphere Community Climate Model (MACCM2), and the Geophysical Fluid Dynamics Laboratory (GFDL) "SKYHI" model, respectively. Time series of isentropic equivalent length show that these models are able to capture major mixing and transport properties observed by CLAES, such as the formation and destruction of polar barriers, the presence of surf zones in both hemispheres. Differences between each model simulation and the observation are examined in light of model performance. Among these differences, only the simulation driven by GEOS DAS shows one case of the "top-down" destruction of the Antarctic polar vortex, as observed in the CLAES data. Additional experiments of isentropic advection of artificial tracer by GEOS DAS winds suggest that diabatic movement might have considerable contribution to the equivalent length field in the 3D CTM diagnostics.

  11. Bioinformatics analysis for evaluation of the diagnostic potentialities of miR-19b, -125b and -205 as liquid biopsy markers of prostate cancer

    NASA Astrophysics Data System (ADS)

    Bryzgunova, O. E.; Lekchnov, E. A.; Zaripov, M. M.; Yurchenko, Yu. B.; Yarmoschuk, S. V.; Pashkovskaya, O. A.; Rykova, E. Yu.; Zheravin, A. A.; Laktionov, P. P.

    2017-09-01

    Presence of tumor-derived cell-free miRNA in biological fluids as well as simplicity and robustness of cell-free miRNA quantification makes them suitable markers for cancer diagnostics. Based on previously published data demonstrating diagnostic potentialities of miR-205 in blood and miR-19b as well as miR-125b in urine of prostate cancer patients, bioinformatics analysis was carried out to follow their involvement in prostate cancer development and select additional miRNA-markers for prostate cancer diagnostics. Studied miRNAs are involved in different signaling pathways and regulate a number of genes involved in cancer development. Five of their targets (CCND1, BRAF, CCNE1, CCNE2, RAF1), according to the STRING database, act as part of the same signaling pathway. RAF1 is regulated by miR-19b and miR-125b, and it was shown to be involved in prostate cancer development by DIANA and STRING databases. Thus, other microRNAs regulating RAF1 expression such as miR-16, -195, -497, and -7 (suggested by DIANA, TargetScan, MiRTarBase and miRDB databases) can potentially be regarded as prostate cancer markers.

  12. Bowel preparations for capsule endoscopy: a comparison between simethicone and magnesium citrate.

    PubMed

    Esaki, Motohiro; Matsumoto, Takayuki; Kudo, Tetsuji; Yanaru-Fujisawa, Ritsuko; Nakamura, Shotaro; Iida, Mitsuo

    2009-01-01

    Bowel preparation for capsule endoscopy (CE) has not been standardized. This study aimed to compare CE images between patients prepared by simethicone and those prepared by magnesium citrate. Retrospective analysis of case series of our hospital from 2004 to 2007. Single center. CE images of 75 patients receiving bowel preparation either by 200 mg of simethicone (n=39) or by 34 g of magnesium citrate (n=36) were retrospectively investigated. Grades of fluid transparency and mucosal invisibility by air bubbles and food residue were compared between the 2 preparations. Capsule transit time, frequency of positive findings, and interobserver variations between 2 observers were also investigated. Image quality and diagnostic yield of CE. Fluid transparency in the first and the third time segments of the small intestine was better in patients prepared by magnesium citrate than in those prepared by simethicone (P= .001 and P= .03, respectively). On the other hand, mucosal invisibility was not different in any part of the small intestine between the 2 groups. Neither gastric transit time nor small-bowel transit time was different between the 2 groups. The diagnostic yield of CE correlated significantly with fluid transparency (P= .04), but it did not correlate with mucosal invisibility. Single-center retrospective study. Magnesium citrate seems to be a recommended preparation for CE compared with simethicone. The fluid transparency, rather than the mucosal invisibility, may be a factor associated with the diagnostic yield of CE.

  13. A comparison of early diagnostic utility of Alzheimer disease biomarkers in brain magnetic resonance and cerebrospinal fluid.

    PubMed

    Monge Argilés, J A; Blanco Cantó, M A; Leiva Salinas, C; Flors, L; Muñoz Ruiz, C; Sánchez Payá, J; Gasparini Berenguer, R; Leiva Santana, C

    2014-09-01

    The goals of this study were to compare the early diagnostic utility of Alzheimer disease biomarkers in the CSF with those in brain MRI in conditions found in our clinical practice, and to ascertain the diagnostic accuracy of both techniques used together. Between 2008 and 2009, we included 30 patients with mild cognitive impairment (MCI) who were examined using 1.5 Tesla brain MRI and AD biomarker analysis in CSF. MRI studies were evaluated by 2 radiologists according to the Korf́s visual scale. CSF biomarkers were analysed using INNOTEST reagents for Aβ1-42, total-tau and phospho-tau181p. We evaluated clinical changes 2 years after inclusion. By 2 years after inclusion, 15 of the original 30 patients (50%) had developed AD (NINCDS-ADRA criteria). The predictive utility of AD biomarkers in CSF (RR 2.7; 95% CI, 1.1-6.7; P<.01) was greater than that of MRI (RR 1.5; 95% CI 95%, 0.7-3.4; P<.2); using both techniques together yielded a sensitivity and a negative predictive value of 100%. Normal results on both complementary tests ruled out progression to AD (100%) within 2 years of inclusion. Our results show that the diagnostic accuracy of biomarkers in CSF is higher than that of biomarkers in MRI. Combined use of both techniques is highly accurate for either early diagnosis or exclusion of AD in patients with MCI. Copyright © 2013 Sociedad Española de Neurología. Published by Elsevier Espana. All rights reserved.

  14. Accuracy of Neck stiffness, Kernig, Brudzinski, and Jolt Accentuation of Headache Signs in Early Detection of Meningitis.

    PubMed

    Ala, Alireza; Rahmani, Farzad; Abdollahi, Sima; Parsian, Zahra

    2018-01-01

    The diagnostic value of clinical signs in early diagnosis of meningitis has been evaluated but the existing results are contradicting. The present study aimed to evaluate the accuracy of Kernig, Brudzinski, neck stiffness, and Jolt Accentuation of Headache (JAH) signs in this regard. In this diagnostic accuracy study, patients with suspected meningitis who were referred to the emergency department were examined regarding presence or absence of the mentioned clinical signs and screening performance characteristics of the signs were calculated. Cerebrospinal fluid analysis was used as the reference test. 120 cases with mean age of 48.79 ± 21.68 years (18 - 93) were studied (63.3% male). Diagnosis of meningitis was confirmed for 45 (37.5%) cases. Neck stiffness (p < 0.001), Kernig (p < 0.001), Brudzinski (p < 0.001), and JAH (p < 0.001) had significantly higher frequency among patients with meningitis. The accuracy of neck stiffness, Kernig, Brudzinski, and JAH signs in early detection of meningitis were 0.676 (95% CI: 0.575-0.776), 0.667 (95% CI: 0.552-0.782), 0.720 (95% CI: 0.619-0.821), 0.749 (95% CI: 0.659-839), respectively. It seems that diagnostic value of JAH is higher than other clinical signs but the accuracy of all signs is in poor to fair range. JAH had the highest sensitivity and Kernig and Brudzinski had the highest specificity.

  15. Cough-variant asthma: a diagnostic dilemma in the occupational setting.

    PubMed

    Lipińska-Ojrzanowska, A; Wiszniewska, M; Walusiak-Skorupa, J

    2015-03-01

    Cough-variant asthma (Corrao's syndrome) is defined as the presence of chronic non-productive cough in patients with bronchial hyperresponsiveness (BHR) and response to bronchodilator therapy. This variant of asthma may present a diagnostic problem in occupational medicine. To describe additional evaluation of cough-variant asthma in a cyanoacrylate-exposed worker in whom standard diagnostic testing was negative. A female beautician was evaluated for suspected occupational allergic rhinitis and asthma. A specific inhalation challenge test (SICT) was performed with cyanoacrylate glues used for applying artificial eyelashes and nails. Spirometry and peak expiratory flow (PEF) measurements were recorded hourly for 24h; methacholine challenge testing was performed and nasal lavage (NL) samples were analysed for eosinophilia. After SICT, the patient developed sneezing, nasal airflow obstruction and cough. Declines in forced expiratory volume in 1 s and PEF were not observed. Eosinophil proportions in NL fluid increased markedly at 4 and 24h after SICT. A significant increase in BHR also occurred 24h after SICT. Clinical symptoms, post-challenge BHR and increased NL eosinophil counts confirmed a positive response to SICT and validated the diagnosis of cough-variant occupational asthma. SICT may be useful in cases where history and clinical data suggest cough-variant asthma and spirometric indices are negative. © The Author 2014. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. How Reliable Is the Alpha-defensin Immunoassay Test for Diagnosing Periprosthetic Joint Infection? A Prospective Study.

    PubMed

    Bonanzinga, Tommaso; Zahar, Akos; Dütsch, Michael; Lausmann, Christian; Kendoff, Daniel; Gehrke, Thorsten

    2017-02-01

    A key issue in the treatment of periprosthetic joint infection (PJI) is the correct diagnosis. The main problem is lack of diagnostic tools able to diagnose a PJI with high accuracy. Alpha-defensin has been proposed as a possible solution, but in the current literature, there is a lack of independent validation. We performed a prospective study to determine (1) what is the sensitivity, specificity, and positive and the negative predictive values of the alpha-defensin immunoassay test in diagnosing PJI; and (2) which clinical features may be responsible for false-positive and false-negative results? Preoperative aspiration was performed in all patients presenting with a painful hip/knee arthroplasty, including both primary and revision implants. Metallosis, other inflammatory comorbidities, and previous/concomitant antibiotic therapy were not considered as exclusion criteria. An inadequate amount of synovial fluid for culture was an exclusion criterion. A total of 156 patients (65 knees, 91 hips) were included in this prospective study. At the time of revision, synovial fluid samples were taken to perform the alpha-defensin assay. During surgical débridement of tissue, samples for cultures and histologic evaluation were taken, and samples were cultured until positive or until negative at 14 days. A diagnosis of PJI was confirmed in 29 patients according to the International Consensus Group on PJI. The sensitivity of the alpha-defensin immunoassay was 97% (95% confidence interval [CI], 92%-99%), the specificity was 97% (95% CI, 92%-99%), the positive predictive value was 88% (95% CI, 81%-92%), and the negative predictive value was 99% (95% CI, 96%-99%). Among four false-positive patients, two had metallosis and one had polyethylene wear. The false-negative case presented with a draining sinus, and intraoperative cultures were also negative. Alpha-defensin assay appears to be a reliable test, but followup evaluation is needed to estimate longer term performance of the test. The authors believe that alpha-defensin has demonstrated itself to be sufficiently robust that PJI diagnostic criteria now should include this test. Future studies are needed to compare the differences among the diagnostic capability of the available tests, in particular when metallosis is present, because metallosis may predispose the test to a false-positive result. Level I, diagnostic study.

  17. Comparison of Diagnostic Accuracy of Periprosthetic Tissue Culture in Blood Culture Bottles to That of Prosthesis Sonication Fluid Culture for Diagnosis of Prosthetic Joint Infection (PJI) by Use of Bayesian Latent Class Modeling and IDSA PJI Criteria for Classification.

    PubMed

    Yan, Qun; Karau, Melissa J; Greenwood-Quaintance, Kerryl E; Mandrekar, Jayawant N; Osmon, Douglas R; Abdel, Matthew P; Patel, Robin

    2018-06-01

    We have previously demonstrated that culturing periprosthetic tissue in blood culture bottles (BCBs) improves sensitivity compared to conventional agar and broth culture methods for diagnosis of prosthetic joint infection (PJI). We have also shown that prosthesis sonication culture improves sensitivity compared to periprosthetic tissue culture using conventional agar and broth methods. The purpose of this study was to compare the diagnostic accuracy of tissue culture in BCBs (subsequently referred to as tissue culture) to prosthesis sonication culture (subsequently referred to as sonicate fluid culture). We studied 229 subjects who underwent arthroplasty revision or resection surgery between March 2016 and October 2017 at Mayo Clinic in Rochester, Minnesota. Using the Infectious Diseases Society of America (IDSA) PJI diagnostic criteria (omitting culture criteria) as the gold standard, the sensitivity of tissue culture was similar to that of the sonicate fluid culture (66.4% versus 73.1%, P = 0.07) but was significantly lower than that of the two tests combined (66.4% versus 76.9%, P < 0.001). Using Bayesian latent class modeling, which assumes no gold standard for PJI diagnosis, the sensitivity of tissue culture was slightly lower than that of sonicate fluid culture (86.3% versus 88.7%) and much lower than that of the two tests combined (86.3% versus 99.1%). In conclusion, tissue culture in BCBs reached sensitivity similar to that of prosthesis sonicate fluid culture for diagnosis of PJI, but the two tests combined had the highest sensitivity without compromising specificity. The combination of tissue culture in BCBs and sonicate fluid culture is recommended to achieve the highest level of microbiological diagnosis of PJI. Copyright © 2018 American Society for Microbiology.

  18. Optimization of T2-weighted imaging for shoulder magnetic resonance arthrography by synthetic magnetic resonance imaging.

    PubMed

    Lee, Seung Hyun; Lee, Young Han; Hahn, Seok; Yang, Jaemoon; Song, Ho-Taek; Suh, Jin-Suck

    2017-01-01

    Background Synthetic magnetic resonance imaging (MRI) allows reformatting of various synthetic images by adjustment of scanning parameters such as repetition time (TR) and echo time (TE). Optimized MR images can be reformatted from T1, T2, and proton density (PD) values to achieve maximum tissue contrast between joint fluid and adjacent soft tissue. Purpose To demonstrate the method for optimization of TR and TE by synthetic MRI and to validate the optimized images by comparison with conventional shoulder MR arthrography (MRA) images. Material and Methods Thirty-seven shoulder MRA images acquired by synthetic MRI were retrospectively evaluated for PD, T1, and T2 values at the joint fluid and glenoid labrum. Differences in signal intensity between the fluid and labrum were observed between TR of 500-6000 ms and TE of 80-300 ms in T2-weighted (T2W) images. Conventional T2W and synthetic images were analyzed for diagnostic agreement of supraspinatus tendon abnormalities (kappa statistics) and image quality scores (one-way analysis of variance with post-hoc analysis). Results Optimized mean values of TR and TE were 2724.7 ± 1634.7 and 80.1 ± 0.4, respectively. Diagnostic agreement for supraspinatus tendon abnormalities between conventional and synthetic MR images was excellent (κ = 0.882). The mean image quality score of the joint space in optimized synthetic images was significantly higher compared with those in conventional and synthetic images (2.861 ± 0.351 vs. 2.556 ± 0.607 vs. 2.750 ± 0.439; P < 0.05). Conclusion Synthetic MRI with optimized TR and TE for shoulder MRA enables optimization of soft-tissue contrast.

  19. Diagnostic accuracy of PCR in gambiense sleeping sickness diagnosis, staging and post-treatment follow-up: a 2-year longitudinal study.

    PubMed

    Deborggraeve, Stijn; Lejon, Veerle; Ekangu, Rosine Ali; Mumba Ngoyi, Dieudonné; Pati Pyana, Patient; Ilunga, Médard; Mulunda, Jean Pierre; Büscher, Philippe

    2011-02-22

    The polymerase chain reaction (PCR) has been proposed for diagnosis, staging and post-treatment follow-up of sleeping sickness but no large-scale clinical evaluations of its diagnostic accuracy have taken place yet. An 18S ribosomal RNA gene targeting PCR was performed on blood and cerebrospinal fluid (CSF) of 360 T. brucei gambiense sleeping sickness patients and on blood of 129 endemic controls from the Democratic Republic of Congo. Sensitivity and specificity (with 95% confidence intervals) of PCR for diagnosis, disease staging and treatment failure over 2 years follow-up post-treatment were determined. Reference standard tests were trypanosome detection for diagnosis and trypanosome detection and/or increased white blood cell concentration in CSF for staging and detection of treatment failure. PCR on blood showed a sensitivity of 88.4% (84.4-92.5%) and a specificity of 99.2% (97.7-100%) for diagnosis, while for disease staging the sensitivity and specificity of PCR on cerebrospinal fluid were 88.4% (84.8-91.9%) and 82.9% (71.2-94.6%), respectively. During follow-up after treatment, PCR on blood had low sensitivity to detect treatment failure. In cerebrospinal fluid, PCR positivity vanished slowly and was observed until the end of the 2 year follow-up in around 20% of successfully treated patients. For T.b. gambiense sleeping sickness diagnosis and staging, PCR performed better than, or similar to, the current parasite detection techniques but it cannot be used for post-treatment follow-up. Continued PCR positivity in one out of five cured patients points to persistence of living or dead parasites or their DNA after successful treatment and may necessitate the revision of some paradigms about the pathophysiology of sleeping sickness.

  20. Transcriptomic Profiling of Extracellular RNAs Present in Cerebrospinal Fluid Identifies Differentially Expressed Transcripts in Parkinson’s Disease

    PubMed Central

    Hossein-nezhad, Arash; Fatemi, Roya Pedram; Ahmad, Rili; Peskind, Elaine R.; Zabetian, Cyrus P.; Hu, Shu-Ching; Shi, Min; Wahlestedt, Claes; Zhang, Jing; Faghihi, Mohammad Ali

    2016-01-01

    Background: Parkinson’s disease (PD) is a debilitating neurological disorder for which prognostic and diagnostic biomarkers are lacking. Cerebrospinal fluid (CSF) is an accessible body fluid that comes into direct contact with the central nervous system (CNS) and acts as a nuclease-free repository where RNA transcripts shed by brain tissues can reside for extended periods of time. Objective: We studied the RNA species present in the CSF of PD patients to identify novel diagnostic biomarkers. Methods: Small volumes of CSF from 27 PD patients and 30 healthy age- and sex-matched controls were used for RNA extraction followed by next-generation sequencing (RNA-seq) using the Illumina platform. CSF contains a number of fragmented RNA species that were individually sequenced and analyzed. Comparing PD to control subjects, we observed a pool of dysregulated sequencing tags that were further analyzed and validated by quantitative real-time PCR (qRT-PCR). Results: A total of 201 differentially expressed sequencing tags (DETs), including 92 up-regulated and 109 down-regulated DETs were identified. We validated the following DETs by real time PCR in the patient samples: Dnmt1, Ezh2, CCR3, SSTR5,PTPRC, UBC, NDUFV2, BMP7, SCN9, SCN9 antisense (AC010127.3), and long noncoding RNAs AC079630 and UC001lva.4 (close to the LRRK2 gene locus), as potential PD biomarkers. Conclusions: The CSF is a unique environment that contains many species of RNA. Our work demonstrates that CSF can potentially be used to identify biomarkers for the detection and tracking of disease progression and evaluation of therapeutic outcomes. PMID:26889637

  1. Assessing errors in the determination of base excess.

    PubMed

    Mentel, Alexander; Bach, Friedhelm; Schüler, Joerg; Herrmann, Walter; Koster, Andreas; Crystal, George J; Gatzounis, Georgios; Mertzlufft, Fritz

    2002-05-01

    We compared estimates for base excess of extracellular fluid (BE(ecf); mmol/L) obtained in five clinically used blood gas analyzers: AVL Compact 2 (Roche Diagnostics, Mannheim, Germany), Ciba-Corning 860 (Bayer Diagnostics, Fernwald, Germany), IL 1620 (Instrumentation Laboratories, Lexington, MA), Stat Profile Ultra (Nova Biomedical, Waltham, MA), and ABL 510 (Radiometer, Copenhagen, Denmark). A total of 134 measurements per analyzer were obtained in arterial and venous blood samples from 10 patients undergoing cardiac surgery and 65 measurements per analyzer in venous blood samples from 2 healthy volunteers. The blood samples were equilibrated in a tonometer with gases of known composition (37 degrees C). Additional theoretical studies were performed to evaluate the relationship between pH and calculated BE(ecf) value (with varied PCO(2)) using the formulas of the various analyzers. The standard deviations of repeated measurements were 0.24 mmol/L for ABL 510 and approximately 0.45 mmol/L for the other 4 analyzers. The maximal systematic difference between the average of all measurements of each analyzer was 3.7 mmol/L; this was primarily attributable to differences in measuring pH, and, to a lesser extent, to differences in calculation and determination of PCO(2). Comparison of the results from samples with different oxygen saturation showed that the relative alkalinity of deoxygenated hemoglobin (Haldane effect) can also influence the determinations of BE(ecf). A clinically useful way to quantify nonrespiratory disturbances of the acid-base balance is calculation of the base excess of extracellular fluid by using blood gas analyzers. In this study, we found significant variability in estimates of base excess of extracellular fluid obtained with five analyzers from different manufacturers. This variability is attributable to multiple factors, including lack of correction for deoxygenated hemoglobin (Haldane effect).

  2. Diagnostic Evaluation of Nmme Precipitation and Temperature Forecasts for the Continental United States

    NASA Astrophysics Data System (ADS)

    Karlovits, G. S.; Villarini, G.; Bradley, A.; Vecchi, G. A.

    2014-12-01

    Forecasts of seasonal precipitation and temperature can provide information in advance of potentially costly disruptions caused by flood and drought conditions. The consequences of these adverse hydrometeorological conditions may be mitigated through informed planning and response, given useful and skillful forecasts of these conditions. However, the potential value and applicability of these forecasts is unavoidably linked to their forecast quality. In this work we evaluate the skill of four global circulation models (GCMs) part of the North American Multi-Model Ensemble (NMME) project in forecasting seasonal precipitation and temperature over the continental United States. The GCMs we consider are the Geophysical Fluid Dynamics Laboratory (GFDL)-CM2.1, NASA Global Modeling and Assimilation Office (NASA-GMAO)-GEOS-5, The Center for Ocean-Land-Atmosphere Studies - Rosenstiel School of Marine & Atmospheric Science (COLA-RSMAS)-CCSM3, Canadian Centre for Climate Modeling and Analysis (CCCma) - CanCM4. These models are available at a resolution of 1-degree and monthly, with a minimum forecast lead time of nine months, up to one year. These model ensembles are compared against gridded monthly temperature and precipitation data created by the PRISM Climate Group, which represent the reference observation dataset in this work. Aspects of forecast quality are quantified using a diagnostic skill score decomposition that allows the evaluation of the potential skill and conditional and unconditional biases associated with these forecasts. The evaluation of the decomposed GCM forecast skill over the continental United States, by season and by lead time allows for a better understanding of the utility of these models for flood and drought predictions. Moreover, it also represents a diagnostic tool that could provide model developers feedback about strengths and weaknesses of their models.

  3. Estimation of Salivary and Serum Biomarkers in Diabetic and Non Diabetic Patients - A Comparative Study

    PubMed Central

    Ladgotra, Amit; Raj, Seetharamaiah Sunder

    2016-01-01

    Introduction Blood is the gold standard body fluid for diagnosis of Diabetes Mellitus (DM) but saliva offers an alternative to serum as a biological fluid for diagnostic purposes because it contains serum constituents. Aim The study was conducted to estimate and compare serum and salivary glucose, amylase, proteins, calcium and phosphorus levels in DM and healthy subjects and to evaluate whether saliva can be used as a diagnostic fluid in DM patients. Materials and Methods Study consisted of 120 subjects from OPD of Surendera Dental College, Sriganganagar, Rajasthan, India. The study groups were divided into Group I-60 DM patients (Type I & II) and Group II-60 healthy subjects. The saliva and serum samples were collected from each subject and levels of different biochemical parameters were estimated. Results Mean serum level of glucose (211.50 ± 43.82), amylase (79.86 ± 16.23), total proteins (6.65 ± 0.84), calcium (7.17 ± 0.91) and phosphorus (3.68±0.65) as observed in Group I while in Group II, glucose (88.81±11.29), amylase (77.67±14.88), total proteins (6.35±0.76), calcium (7.52±0.97) and phosphorus (3.96 ± 0.91) were noted. Mean salivary level of glucose (14.10±6.99), amylase (1671.42±569.86), total proteins (1.33±1.11), calcium (10.06±2.76) and phosphorus (13.75±4.45) as observed in Group I while in Group II, glucose (5.87± 2.42), amylase (1397.59 ±415.97), total proteins (1.36±0.81), calcium (7.73±2.78) and phosphorus (8.39 ± 1.95) were noted. On comparing values in saliva and serum, among two groups, an insignificant difference (p>0.005) was found between few of them. Conclusion Values regarding blood and salivary biochemical parameters were distinctly different between two groups suggesting salivary parameters can be used as a diagnostic alternative to blood parameters for diabetes mellitus. PMID:27504412

  4. Quick bacteriophage-mediated bioluminescence assay for detecting Staphylococcus spp. in sonicate fluid of orthopaedic artificial joints.

    PubMed

    Šuster, Katja; Podgornik, Aleš; Cör, Andrej

    2017-07-01

    Staphylococcus spp. accounts for up to two thirds of all microorganisms causing prosthetic joint infections, with Staphylococcus aureus and Staphylococcus epidermidis being the major cause. The present study describes a diagnostic model to detect staphylococci using a specific bacteriophage and bioluminescence detection, exploring the possibility of its use on sonicate fluid of orthopaedic artificial joints. Intracellular adenosine-5'-triphosphate release by bacteriophage mediated lysis of staphylococci was assessed to determine optimal parameters for detection. With the optimized method, a limit of detection of around 103 CFU/mL was obtained after incubation with bacteriophage for 2 h. Importantly, sonicate fluid did not prevent the ability of bacteriophage to infect bacteria and all simulated infected sonicate fluid as well as 6 clinical samples with microbiologically proven staphylococcal infection were detected as positive. The total assay took approximately 4 h. Collectively, the results indicate that the developed method promises a rapid, inexpensive and specific diagnostic detection of staphylococci in sonicate fluid of infected prosthetic joints. In addition, the unlimited pool of different existing bacteriophages, with different specificity for all kind of bacteria gives the opportunity for further investigations, improvements of the current model and implementation in other medical fields for the purpose of the establishment of a rapid diagnosis.

  5. Diagnostic Tools of Pleural Effusion

    PubMed Central

    2014-01-01

    Pleural effusion is not a rare disease in Korea. The diagnosis of pleural effusion is very difficult, even though the patients often complain of typical symptoms indicating of pleural diseases. Pleural effusion is characterized by the pleural cavity filled with transudative or exudative pleural fluids, and it is developed by various etiologies. The presence of pleural effusion can be confirmed by radiological studies including simple chest radiography, ultrasonography, or computed tomography. Identifying the causes of pleural effusions by pleural fluid analysis is essential for proper treatments. This review article provides information on the diagnostic approaches of pleural effusions and further suggested ways to confirm their various etiologies, by using the most recent journals for references. PMID:24920946

  6. Contribution of sonicate-fluid cultures and broad-range PCR to microbiological diagnosis in vascular graft infections.

    PubMed

    Kokosar Ulcar, Barbara; Lakic, Nikola; Jeverica, Samo; Pecavar, Blaz; Logar, Mateja; Cerar, Tjasa Kisek; Lejko-Zupanc, Tatjana

    2018-06-01

    Vascular graft infections (VGI) are associated with considerable morbidity and mortality, and antimicrobial treatment is an important adjunct to surgical treatment. While microbial aetiology of VGI is often difficult to determine, other techniques such as sonication of implanted material may be used to enhance the recovery of biofilm-associated organisms. We performed a retrospective analysis of 22 consecutive patients treated for VGI at University Medical Centre Ljubljana from May 2011 through January 2015. Explanted vascular grafts were flooded with sterile Ringer solution, sonicated for 1 min at a frequency of 40 kHz and inoculated on solid and liquid culture media. Aerobic and anaerobic cultures were performed, incubated for 14 days and any significant bacterial growth was quantitatively evaluated. Additionally, broad-range PCR from sonicate fluid was performed. Microbiological results were compared with the results of preoperatively taken blood cultures and the results of intraoperative tissue cultures (material from peri-graft collection). Identification of the causative organism (irrespective of the method) was achieved in 95.8%. Preoperative blood cultures were positive in 35.3%, intraoperative tissue cultures in 31.8%, sonicate fluid culture in 79.2%, while broad-range PCR from sonicate fluid was positive in 66.7%. In 37.5% the pathogen detected in sonicate fluid culture or broad-range PCR was the only positive microbiological result. Sonicate fluid culture and broad-range PCR from explanted vascular grafts may contribute to optimization of antimicrobial treatment. Optimal timing of antibiotic therapy before explantation should be further assessed to improve diagnostic yield.

  7. Cytomegalovirus infection in immunocompetent wheezy infants: the diagnostic value of CMV PCR in bronchoalveolar lavage fluid.

    PubMed

    Cinel, G; Pekcan, S; Ozçelik, U; Alp, A; Yalçın, E; Doğru Ersöz, D; Kiper, N

    2014-08-01

    Cytomegalovirus (CMV) pneumonitis in immunocompetent hosts is uncommon but is being recognized more frequently, particularly when presenting as severe viral pneumonia. The objective of this study was to examine lower respiratory tract CMV infection in immunocompetent wheezy infants, based on polymerase chain reaction (PCR) in bronchoalveolar lavage (BAL) fluid, to compare CMV PCR results in BAL and in blood samples and to evaluate the benefits of antiviral ganciclovir therapy in these patients. Retrospective review of the records of patients referred to our tertiary care hospital between January 2000 and July 2010 who had unexplained persistent wheezing and underwent fibreoptic flexible bronchoscopy (FFB). Fibreoptic flexible bronchoscopy was applied to 102 infants with persistent wheezing and diffuse interstitial infiltration on radiological investigations; so CMV PCR in BAL fluid was performed. CMV PCR in BAL fluid was positive in 51 patients. Retrospectively, we had access to the files of 25 of these patients. The mean CMV PCR in BAL fluid was 334 840 copies/mL. Only eight patients had CMV PCR positivity in their blood samples (mean: 2026·3 copies/mL). There was not a relationship between BAL and blood CMV PCR values based on Spearman's correlation analysis (r = -0·008). Fourteen patients had severe respiratory symptoms and received ganciclovir therapy. Twelve of them fully recovered. Bronchoalveolar lavage fluid CMV PCR was superior to blood CMV PCR in diagnosing lower respiratory tract infections caused by CMV in immunocompetent infants. Ganciclovir therapy may be effective in selected immunocompetent wheezy infants with CMV PCR positivity in BAL fluid. © 2014 John Wiley & Sons Ltd.

  8. A comparative analysis of conventional cytopreparatory and liquid based cytological techniques (Sure Path) in evaluation of serous effusion fluids.

    PubMed

    Dadhich, Hrishikesh; Toi, Pampa Ch; Siddaraju, Neelaiah; Sevvanthi, Kalidas

    2016-11-01

    Clinically, detection of malignant cells in serous body fluids is critical, as their presence implies the upstaging of the disease. Cytology of body cavity fluids serves as an important tool when other diagnostic tests cannot be performed. In most laboratories, currently, the effusion fluid samples are analysed chiefly by the conventional cytopreparatory (CCP) technique. Although, there are several studies comparing the liquid-based cytology (LBC), with CCP technique in the field of cervicovaginal cytology; the literature on such comparison with respect to serous body fluid examination is sparse. One hundred samples of serous body fluids were processed by both CCP and LBC techniques. Slides prepared by these techniques were studied using six parameters. A comparative analysis of the advantages and disadvantages of the techniques in detection of malignant cells was carried out with appropriate statistical tests. The samples comprised 52 pleural, 44 peritoneal and four pericardial fluids. No statistically significant difference was noted with respect to cellularity (P values = 0.22), cell distribution (P values = 0.39) and diagnosis of malignancy (P values = 0.20). As for the remaining parameters, LBC provided statistically significant clearer smear background (P values < 0.0001) and shorter screening time (P values < 0.0001), while CPP technique provided a significantly better staining quality (P values 0.01) and sharper cytomorphologic features (P values 0.05). Although, a reduced screening time and clearer smear background are the two major advantages of LBC; the CCP technique provides the better staining quality with sharper cytomorphologic features which is more critical from the cytologic interpretation point of view. Diagn. Cytopathol. 2016;44:874-879. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  9. The role of synovial fluid analysis in the detection of periprosthetic hip and knee infections: a systematic review and meta-analysis.

    PubMed

    De Fine, Marcello; Giavaresi, Gianluca; Fini, Milena; Illuminati, Andrea; Terrando, Silvio; Pignatti, Giovanni

    2018-05-01

    This study tried to ascertain (1) the accuracy of synovial fluid white blood cell count and polymorphonucleate percentage in the diagnosis of periprosthetic hip and knee infections, (2) which test yielded superior test performance, and (3) the influence on diagnostic accuracy of study characteristics such as patient number, study design, study level, anatomic site, and threshold value. A systematic search was conducted including papers assessing more effective cutoffs for synovial fluid tests, having comparative design, evaluating an exclusive cohort of hip or knee prostheses, including a clear definition of infected cases, and reporting sufficient data for the calculation of true-positive, false-positive, false-negative, and true-negative. A total of 375 articles were collected and, given the inclusion criteria, ten manuscripts were included. These studies assessed 1155 hip prostheses (276 infected cases) and 1235 knee prostheses (401 infected cases). The specificity of synovial fluid white blood cell count was significantly increased by using the threshold value ≥ 3000 cell/μL (p = 0.006); the sensitivity of polymorphonucleate percentage was significantly higher in detecting knee infections (p = 0.034). Both tests had a high specificity and sensitivity in detecting periprosthetic joint infections, and no clear superiority of one over the other existed. Furthermore, cutoff and anatomic site significantly influenced synovial fluid white blood cell count and polymorphonucleate percentage, respectively. Synovial fluid analysis is adequate in differentiating patients with periprosthetic hip and knee infections. Our data confirms international guidelines suggesting the use of 3000 cell/μL as cutoff threshold for synovial fluid white blood cell count. Since an anatomic site effect has been demonstrated, the goal of future studies will be to identify different cutoffs for hip and knee prostheses.

  10. Loop-mediated isothermal amplification assay for detection of Haemophilus influenzae type b in cerebrospinal fluid.

    PubMed

    Kim, Dong Wook; Kilgore, Paul Evan; Kim, Eun Jin; Kim, Soon Ae; Anh, Dang Duc; Seki, Mitsuko

    2011-10-01

    Haemophilus influenzae type b (Hib) is one of the leading causes of meningitis in developing countries. To establish and evaluate a novel loop-mediated isothermal amplification (LAMP) assay for Hib, we designed a LAMP primer set targeting the Hib-specific capsulation locus. LAMP detected 10 copies of purified DNA in a 60-min reaction. This indicated that the detection limit of LAMP was >100-fold lower than the detection limits of both a PCR for the detection of bexA and a nested PCR for Hib (Hib PCR). No H. influenzae, other than Hib or control bacteria, was detected. Linear determination ranged from 10 to 1,000,000 microorganisms per reaction mixture using real-time turbidimetry. We evaluated the Hib LAMP assay using a set of 52 randomly selected cerebrospinal fluid (CSF) specimens obtained from children with suspected meningitis. For comparison, the CSF specimens were tested using a conventional Hib PCR assay. Hib was detected in 30 samples using LAMP and in 22 samples using the Hib PCR assay. The Hib PCR showed a clinical sensitivity of 73.3% and a clinical specificity of 100% relative to the Hib LAMP assay. These results suggest that further development and evaluation of the Hib LAMP will enhance the global diagnostic capability for Hib detection.

  11. Manipulation of fluids in three-dimensional porous photonic structures with patterned surface properties

    DOEpatents

    Aizenberg, Joanna; Burgess, Ian B.; Mishchenko, Lidiya; Hatton, Benjamin; Loncar, Marko

    2016-03-08

    A three-dimensional porous photonic structure, whose internal pore surfaces can be provided with desired surface properties in a spatially selective manner with arbitrary patterns, and methods for making the same are described. When exposed to a fluid (e.g., via immersion or wicking), the fluid can selectively penetrate the regions of the structure with compatible surface properties. Broad applications, for example in security, encryption and document authentication, as well as in areas such as simple microfluidics and diagnostics, are anticipated.

  12. Manipulation of fluids in three-dimensional porous photonic structures with patterned surface properties

    DOEpatents

    Aizenberg, Joanna; Burgess, Ian; Mishchenko, Lidiya; Hatton, Benjamin; Loncar, Marko

    2017-12-26

    A three-dimensional porous photonic structure, whose internal pore surfaces can be provided with desired surface properties in a spatially selective manner with arbitrary patterns, and methods for making the same are described. When exposed to a fluid (e.g., via immersion or wicking), the fluid can selectively penetrate the regions of the structure with compatible surface properties. Broad applications, for example in security, encryption and document authentication, as well as in areas such as simple microfluidics and diagnostics, are anticipated.

  13. Fully 3D printed integrated reactor array for point-of-care molecular diagnostics.

    PubMed

    Kadimisetty, Karteek; Song, Jinzhao; Doto, Aoife M; Hwang, Young; Peng, Jing; Mauk, Michael G; Bushman, Frederic D; Gross, Robert; Jarvis, Joseph N; Liu, Changchun

    2018-06-30

    Molecular diagnostics that involve nucleic acid amplification tests (NAATs) are crucial for prevention and treatment of infectious diseases. In this study, we developed a simple, inexpensive, disposable, fully 3D printed microfluidic reactor array that is capable of carrying out extraction, concentration and isothermal amplification of nucleic acids in variety of body fluids. The method allows rapid molecular diagnostic tests for infectious diseases at point of care. A simple leak-proof polymerization strategy was developed to integrate flow-through nucleic acid isolation membranes into microfluidic devices, yielding a multifunctional diagnostic platform. Static coating technology was adopted to improve the biocompatibility of our 3D printed device. We demonstrated the suitability of our device for both end-point colorimetric qualitative detection and real-time fluorescence quantitative detection. We applied our diagnostic device to detection of Plasmodium falciparum in plasma samples and Neisseria meningitides in cerebrospinal fluid (CSF) samples by loop-mediated, isothermal amplification (LAMP) within 50 min. The detection limits were 100 fg for P. falciparum and 50 colony-forming unit (CFU) for N. meningitidis per reaction, which are comparable to that of benchtop instruments. This rapid and inexpensive 3D printed device has great potential for point-of-care molecular diagnosis of infectious disease in resource-limited settings. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Hydroxyalkyl phosphine gold complexes for use as diagnostic and therapeutic pharmaceuticals and method of making same

    DOEpatents

    Katti, Kattesh V.; Berning, Douglas E.; Volkert, Wynn A.; Ketring, Alan R.

    1998-01-01

    A complex and method for making same for use as a diagnostic or therapeutic pharmaceutical includes a ligand comprising at least one hydroxyalkyl phosphine donor group bound to a gold atom to form a gold-ligand complex that is stable in aqueous solutions containing oxygen, serum and other body fluids.

  15. Hydroxyalkyl phosphine gold complexes for use as diagnostic and therapeutic pharmaceuticals and method of making same

    DOEpatents

    Katti, K.V.; Berning, D.E.; Volkert, W.A.; Ketring, A.R.

    1998-12-01

    A complex and method for making a diagnostic or therapeutic pharmaceutical includes a ligand comprising at least one hydroxyalkyl phosphine donor group bound to a gold atom to form a gold-ligand complex that is stable in aqueous solutions containing oxygen, serum and other body fluids. 20 figs.

  16. Diagnostic Accuracy of Antigen 5-Based ELISAs for Human Cystic Echinococcosis

    PubMed Central

    Pagnozzi, Daniela; Addis, Maria Filippa; Biosa, Grazia; Roggio, Anna Maria; Tedde, Vittorio; Mariconti, Mara; Tamarozzi, Francesca; Meroni, Valeria; Masu, Gabriella; Masala, Giovanna; Brunetti, Enrico; Uzzau, Sergio

    2016-01-01

    Background Clinical diagnosis and follow up of cystic echinococcosis (CE) are based on imaging complemented by serology. Several immunodiagnostic tests are commercially available, but the development of new tools is still needed to overcome the lack of standardization of the target antigen, generally consisting of a crude extract of Echinococcus granulosus hydatid cyst fluid. In a previous work, we described a chromatographic method for the preparation of a highly enriched Antigen 5 fraction from hydatid cyst fluid. The high reactivity of patient sera against this preparation prompted us to evaluate further this antigen for the serodiagnosis of CE on a larger cohort of samples. Methodology/Principal Findings A total of 327 sera from CE patients with heterogeneous conditions for cyst stage, cyst number, organ localization, drug therapy, and surgical intervention, together with 253 sera from healthy controls, were first analyzed by an ELISA based on the Ag5 preparation in two different experimental setups and, in parallel, by a commercial ELISA routinely used in clinical laboratories for CE serodiagnosis. The Ag5 ELISAs revealed different sensitivity (88.3% vs 95.3%) without significant differences in specificity (94.1% vs 92.5%), for the two setups, respectively. Moreover, possible relationships between the Ag5 ELISA absorbance results and clinical variables were investigated. Chi squared test, bivariate logistic regression and multiple regression analyses highlighted differences in the serology reactivity according to pharmacological treatment, cyst activity, and cyst number. Conclusions/Significance The two Ag5 ELISAs revealed different performances depending on the setup. The good diagnostic sensitivity and the high reliability of the Ag5 preparation method make this antigen a promising candidate for the serodiagnosis of CE. Further studies will be needed to evaluate the ability of our test to provide useful information on specific CE clinical traits. PMID:27023205

  17. Diagnostic performance of blood culture bottles for vitreous culture compared to conventional microbiological cultures in patients with suspected endophthalmitis.

    PubMed

    Kehrmann, Jan; Chapot, Valerie; Buer, Jan; Rating, Philipp; Bornfeld, Norbert; Steinmann, Joerg

    2018-05-01

    The purpose of this investigation was to evaluate the performance of blood culture bottles in comparison to conventional microbiological culture techniques in detecting causative microorganisms of endophthalmitis and to determine their anti-infective susceptibility profiles. All consecutive cases with clinically suspected endophthalmitis in a university-based ophthalmology department between January 2009 and December 2016 were analysed in this retrospective comparative case series. Samples from 247 patients with suspected endophthalmitis underwent microbiological diagnostic work-up. All three culture methods were performed from 140 vitreous specimens. Vitreous fluid specimens were inoculated in blood culture bottles, aerobic and anaerobic broth solutions, and on solid media. Anti-infective susceptibility profiles were evaluated by semi-automated methods and/or gradient diffusion methods. Microorganisms were grown in 82 of 140 specimens for which all methods were performed (59%). Microorganisms were more frequently grown from blood culture bottles (55%) compared to broth solution (45%, p = 0.007) and solid media (33%, p < 0.0001). Considerable differences in the performance among culture media were detected for fungal pathogens. All grown fungi were detected by blood culture bottles (11 of 11, 100%). Broth solution recovered 64% and solid media 46% of grown fungi. No Gram-positive bacterium was resistant to vancomycin and all Gram-negative pathogens except for one isolate were susceptible to third-generation cephalosporins. In suspected endophthalmitis patients, blood culture bottles have a higher overall pathogen detection rate from vitreous fluid compared to conventional microbiological media, especially for fungi. The initial intravitreal antibiotic therapy with vancomycin plus third-generation cephalosporins appears to be an appropriate treatment approach for bacterial endophthalmitis.

  18. Diagnostic workup, etiologies and management of acute right ventricle failure : A state-of-the-art paper.

    PubMed

    Vieillard-Baron, Antoine; Naeije, R; Haddad, F; Bogaard, H J; Bull, T M; Fletcher, N; Lahm, T; Magder, S; Orde, S; Schmidt, G; Pinsky, M R

    2018-05-09

    This is a state-of-the-art article of the diagnostic process, etiologies and management of acute right ventricular (RV) failure in critically ill patients. It is based on a large review of previously published articles in the field, as well as the expertise of the authors. The authors propose the ten key points and directions for future research in the field. RV failure (RVF) is frequent in the ICU, magnified by the frequent need for positive pressure ventilation. While no universal definition of RVF is accepted, we propose that RVF may be defined as a state in which the right ventricle is unable to meet the demands for blood flow without excessive use of the Frank-Starling mechanism (i.e. increase in stroke volume associated with increased preload). Both echocardiography and hemodynamic monitoring play a central role in the evaluation of RVF in the ICU. Management of RVF includes treatment of the causes, respiratory optimization and hemodynamic support. The administration of fluids is potentially deleterious and unlikely to lead to improvement in cardiac output in the majority of cases. Vasopressors are needed in the setting of shock to restore the systemic pressure and avoid RV ischemia; inotropic drug or inodilator therapies may also be needed. In the most severe cases, recent mechanical circulatory support devices are proposed to unload the RV and improve organ perfusion CONCLUSION: RV function evaluation is key in the critically-ill patients for hemodynamic management, as fluid optimization, vasopressor strategy and respiratory support. RV failure may be diagnosed by the association of different devices and parameters, while echocardiography is crucial.

  19. Technical feasibility, diagnostic yield, and safety of microforceps biopsies during EUS evaluation of pancreatic cystic lesions (with video).

    PubMed

    Mittal, Chetan; Obuch, Joshua C; Hammad, Hazem; Edmundowicz, Steven A; Wani, Sachin; Shah, Raj J; Brauer, Brian C; Attwell, Augustin R; Kaplan, Jeffrey B; Wagh, Mihir S

    2018-05-01

    Through-the-needle microforceps are a recent addition to the EUS armamentarium for evaluation of pancreatic cystic lesions (PCLs). The main aim of this study was to assess the technical feasibility, diagnostic yield, and safety of EUS-guided microforceps biopsy for PCLs. Our electronic endoscopy database was queried to identify patients who underwent EUS-guided FNA (EUS-FNA) of PCLs and microforceps biopsies during the same procedure. A biopsy was done on the wall of the cyst with the microforceps through the 19-gauge needle, and cyst fluid was collected for cytology and carcinoembryonic antigen (CEA) levels. Adverse events were recorded per published American Society for Gastrointestinal Endoscopy criteria. Twenty-seven patients underwent EUS-FNA and microforceps biopsy of PCLs from February 2016 to July 2017. Fourteen cysts were located in the pancreatic head and/or uncinate, and 13 were located in the body and/or tail region. Microforceps biopsies were technically successful in all cases and provided a pathology diagnosis in 24 of 27 cases (yield 88.9%). Microforceps biopsies diagnosed mucinous cyst in 9 patients (33.3%), serous cystadenoma in 4 (14.8%), neuroendocrine tumor in 1 (3.7%), and benign and/or inflammatory cyst in 10 (37.1%). In 7 patients (26%), microforceps biopsy results drastically changed the diagnosis, providing diagnoses otherwise not suggested by cytology or cyst fluid CEA levels. However, cytology provided a diagnosis of mucinous cyst in 4 cases (14.8%) not detected by microforceps biopsies. No adverse events were noted. Microforceps biopsies were associated with high technical success, and an excellent safety profile and may be a useful adjunctive tool, complementing existing EUS-FNA sampling protocols for PCLs. Copyright © 2018 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  20. Peptidomics of urine and other biofluids for cancer diagnostics.

    PubMed

    Bauça, Josep Miquel; Martínez-Morillo, Eduardo; Diamandis, Eleftherios P

    2014-08-01

    Cancer is a leading cause of death worldwide. The low diagnostic sensitivity and specificity of most current cancer biomarkers make early cancer diagnosis a challenging task. The comprehensive study of peptides and small proteins in a living system, known as "peptidomics," represents an alternative technological approach to the discovery of potential biomarkers for the assessment of a wide variety of pathologies. This review examines the current status of peptidomics for several body fluids, with a focus on urine, for cancer diagnostics applications. Several studies have used high-throughput technologies to characterize the peptide content of different body fluids. Because of its noninvasive collection and high stability, urine is a valuable source of candidate cancer biomarkers. A wide variety of preanalytical issues concerning patient selection and sample handling need to be considered, because not doing so can affect the quality of the results by introducing bias and artifacts. Optimization of both the analytical strategies and the processing of bioinformatics data is also essential to minimize the false-discovery rate. Peptidomics-based studies of urine and other body fluids have yielded a number of biomolecules and peptide panels with potential for diagnosing different types of cancer, especially of the ovary, prostate, and bladder. Large-scale studies are needed to validate these molecules as cancer biomarkers. © 2013 American Association for Clinical Chemistry.

  1. A Comprehensive Evaluation of Xpert MTB/RIF Assay With Bronchoalveolar Lavage Fluid as a Single Test or Combined With Conventional Assays for Diagnosis of Pulmonary Tuberculosis in China: A Two-Center Prospective Study

    PubMed Central

    Pan, Xiaofu; Yang, Shoufeng; Deighton, Margaret A.; Qu, Yue; Hong, Liang; Su, Feifei

    2018-01-01

    Introduction: The Xpert MTB/RIF is recommended by the World Health Organization as a first line rapid test for the diagnosis of pulmonary tuberculosis (TB); however, China does not routinely use this test, partially due to the lack of a sufficient number of systematic evaluations of this assay in local patients. The aims of this study were to comprehensively assess the diagnostic performance of Xpert MTB/RIF, either alone or in combination with conventional assays for the diagnosis of pulmonary TB in adult Chinese patients. Methods: Xpert MTB/RIF tests were performed in 190 adult patients with suspected pulmonary TB, using bronchoalveolar lavage fluid (BALF) as test specimens. In parallel, conventional tests were carried out using the same BALF samples. Using two different reference standards, the performance of Xpert MTB/RIF, conventional assays and their combinations were evaluated. Results: Using mycobacterial culture as the reference comparator, Xpert MTB/RIF was found to be superior to smear-microscopy in detecting Mycobacterium tuberculosis. When final diagnosis, based on clinical criteria, was employed as the reference standard, Xpert MTB/RIF showed an even higher accuracy of 72.1%, supported by a sensitivity of 61.1% and specificity of 96.6%. Xpert MTB/RIF also demonstrated a powerful capability to identify pulmonary TB cases undetected by culture or smear-microscopy. Combining smear-microscopy and Xpert MTB/RIF was found to be the most accurate early predictor for pulmonary TB. Rifampicin resistance reported by Xpert MTB/RIF slightly deviated from that by phenotypic antibiotic susceptibility testing and requires further study with a larger sample size. Conclusion: This two-center prospective study highlights the value of Xpert MTB/RIF with BALF in diagnosing pulmonary TB in adult Chinese patients. These findings might contribute to the optimization of current diagnostic algorithms for pulmonary TB in China. PMID:29593688

  2. A Comprehensive Evaluation of Xpert MTB/RIF Assay With Bronchoalveolar Lavage Fluid as a Single Test or Combined With Conventional Assays for Diagnosis of Pulmonary Tuberculosis in China: A Two-Center Prospective Study.

    PubMed

    Pan, Xiaofu; Yang, Shoufeng; Deighton, Margaret A; Qu, Yue; Hong, Liang; Su, Feifei

    2018-01-01

    Introduction: The Xpert MTB/RIF is recommended by the World Health Organization as a first line rapid test for the diagnosis of pulmonary tuberculosis (TB); however, China does not routinely use this test, partially due to the lack of a sufficient number of systematic evaluations of this assay in local patients. The aims of this study were to comprehensively assess the diagnostic performance of Xpert MTB/RIF, either alone or in combination with conventional assays for the diagnosis of pulmonary TB in adult Chinese patients. Methods: Xpert MTB/RIF tests were performed in 190 adult patients with suspected pulmonary TB, using bronchoalveolar lavage fluid (BALF) as test specimens. In parallel, conventional tests were carried out using the same BALF samples. Using two different reference standards, the performance of Xpert MTB/RIF, conventional assays and their combinations were evaluated. Results: Using mycobacterial culture as the reference comparator, Xpert MTB/RIF was found to be superior to smear-microscopy in detecting Mycobacterium tuberculosis . When final diagnosis, based on clinical criteria, was employed as the reference standard, Xpert MTB/RIF showed an even higher accuracy of 72.1%, supported by a sensitivity of 61.1% and specificity of 96.6%. Xpert MTB/RIF also demonstrated a powerful capability to identify pulmonary TB cases undetected by culture or smear-microscopy. Combining smear-microscopy and Xpert MTB/RIF was found to be the most accurate early predictor for pulmonary TB. Rifampicin resistance reported by Xpert MTB/RIF slightly deviated from that by phenotypic antibiotic susceptibility testing and requires further study with a larger sample size. Conclusion: This two-center prospective study highlights the value of Xpert MTB/RIF with BALF in diagnosing pulmonary TB in adult Chinese patients. These findings might contribute to the optimization of current diagnostic algorithms for pulmonary TB in China.

  3. Six-minute magnetic resonance imaging protocol for evaluation of acute ischemic stroke: pushing the boundaries.

    PubMed

    Nael, Kambiz; Khan, Rihan; Choudhary, Gagandeep; Meshksar, Arash; Villablanca, Pablo; Tay, Jennifer; Drake, Kendra; Coull, Bruce M; Kidwell, Chelsea S

    2014-07-01

    If magnetic resonance imaging (MRI) is to compete with computed tomography for evaluation of patients with acute ischemic stroke, there is a need for further improvements in acquisition speed. Inclusion criteria for this prospective, single institutional study were symptoms of acute ischemic stroke within 24 hours onset, National Institutes of Health Stroke Scale ≥3, and absence of MRI contraindications. A combination of echo-planar imaging (EPI) and a parallel acquisition technique were used on a 3T magnetic resonance (MR) scanner to accelerate the acquisition time. Image analysis was performed independently by 2 neuroradiologists. A total of 62 patients met inclusion criteria. A repeat MRI scan was performed in 22 patients resulting in a total of 84 MRIs available for analysis. Diagnostic image quality was achieved in 100% of diffusion-weighted imaging, 100% EPI-fluid attenuation inversion recovery imaging, 98% EPI-gradient recalled echo, 90% neck MR angiography and 96% of brain MR angiography, and 94% of dynamic susceptibility contrast perfusion scans with interobserver agreements (k) ranging from 0.64 to 0.84. Fifty-nine patients (95%) had acute infarction. There was good interobserver agreement for EPI-fluid attenuation inversion recovery imaging findings (k=0.78; 95% confidence interval, 0.66-0.87) and for detection of mismatch classification using dynamic susceptibility contrast-Tmax (k=0.92; 95% confidence interval, 0.87-0.94). Thirteen acute intracranial hemorrhages were detected on EPI-gradient recalled echo by both observers. A total of 68 and 72 segmental arterial stenoses were detected on contrast-enhanced MR angiography of the neck and brain with k=0.93, 95% confidence interval, 0.84 to 0.96 and 0.87, 95% confidence interval, 0.80 to 0.90, respectively. A 6-minute multimodal MR protocol with good diagnostic quality is feasible for the evaluation of patients with acute ischemic stroke and can result in significant reduction in scan time rivaling that of the multimodal computed tomographic protocol. © 2014 American Heart Association, Inc.

  4. Advances in the diagnosis of tuberculous pleuritis

    PubMed Central

    2016-01-01

    Pleural tuberculosis (TB) remains difficult to diagnose. In about two-thirds of the cases the diagnosis is reliant upon clinical suspicion along with consistent fluid biochemistries (i.e., lymphocytic predominant exudates) and exclusion of other potential causes for the effusion. Microbiological methods for a confirmatory diagnosis of pleural TB, which include acid-fast smears (Ziehl-Nelseen), cultures on solid media (Lowenstein-Jensen) and polymerase chain reaction tests from either pleural fluid or sputum samples, remain suboptimal since they are positive in only a minority of patients. Liquid media, however, significantly increase sensitivity while shortening culture positivity as compared with solid cultures. A number of pleural fluid biomarkers such as adenosine deaminase (ADA), interferon-Ƴ, interferon-Ƴ-induced protein of 10 KDa (IP-10) and interleukin-27 (IL-27), have shown promise for the rapid diagnosis of TB, but only ADA combines the accuracy and simplicity required to be considered a mainstay investigative tool for clinical decisions, particularly in areas with medium to high TB prevalence. In countries where ADA is not available, pleural biopsies to evaluate for caseating granulomas are a standard diagnostic approach. They are now frequently performed under ultrasound guidance to optimize yield and patient safety. PMID:27570776

  5. Amplified Detection of Prions and Other Amyloids by RT-QuIC in Diagnostics and the Evaluation of Therapeutics and Disinfectants.

    PubMed

    Caughey, Byron; Orru, Christina D; Groveman, Bradley R; Hughson, Andrew G; Manca, Matteo; Raymond, Lynne D; Raymond, Gregory J; Race, Brent; Saijo, Eri; Kraus, Allison

    2017-01-01

    Among the most sensitive, specific and practical of methods for detecting prions are the real-time quaking-induced conversion (RT-QuIC) assays. These assays exploit the fundamental self-propagating activity of prions to amplify the presence of prion seeds by as much as a trillion-fold. The reactions can detect most of the known mammalian prion diseases, often with sensitivities greater than those of animal bioassays. RT-QuIC assays are performed in multiwell plates with fluorescence detection and have now reached the sensitivity and practicality required for routine prion disease diagnostics. Some key strains of prions within particular host species, e.g., humans, cattle, and sheep, can be discriminated by comparison of RT-QuIC responses with different recombinant prion protein substrates. The most thoroughly validated diagnostic application of RT-QuIC is in the diagnosis of sporadic Creutzfeldt-Jakob disease (sCJD) using cerebrospinal fluid. Diagnostic sensitivities as high as 96% can be achieved in less than 24h with specificities of 98%-100%. The ability, if needed, to also test nasal swab samples can increase the RT-QuIC sensitivity for sCJD to virtually 100%. In addition to diagnostic applications, RT-QuIC has also been used in the testing of prion disinfectants and potential therapeutics. Mechanistically related assays are also now being developed for other protein misfolding diseases. © 2017 Elsevier Inc. All rights reserved.

  6. Diagnosis of Acute Gout: A Clinical Practice Guideline From the American College of Physicians.

    PubMed

    Qaseem, Amir; McLean, Robert M; Starkey, Melissa; Forciea, Mary Ann

    2017-01-03

    The American College of Physicians (ACP) developed this guideline to present the evidence and provide clinical recommendations on the diagnosis of gout. This guideline is based on a systematic review of published studies on gout diagnosis, identified using several databases, from database inception to February 2016. Evaluated outcomes included the accuracy of the test results; intermediate outcomes (results of laboratory and radiographic tests, such as serum urate and synovial fluid crystal analysis and radiographic or ultrasonography changes); clinical decision making (additional testing and pharmacologic or dietary management); short-term clinical (patient-centered) outcomes, such as pain and joint swelling and tenderness; and adverse effects of the tests. This guideline grades the evidence and recommendations by using the ACP grading system, which is based on the GRADE (Grading of Recommendations Assessment, Development and Evaluation) method. The target audience for this guideline includes all clinicians, and the target patient population includes adults with joint inflammation suspected to be gout. ACP recommends that clinicians use synovial fluid analysis when clinical judgment indicates that diagnostic testing is necessary in patients with possible acute gout. (Grade: weak recommendation, low-quality evidence).

  7. Novel Optical Diagnostic Techniques for Studying Particle Deposition Upon Large Cylinders in a Sheared Suspension

    NASA Technical Reports Server (NTRS)

    Yoda, M.; Bailey, B. C.

    2000-01-01

    On a twelve-month voyage to Mars, one astronaut will require at least two tons of potable water and two tons of pure oxygen. Efficient, reliable fluid reclamation is therefore necessary for manned space exploration. Space habitats require a compact, flexible, and robust apparatus capable of solid-fluid mechanical separation over a wide range of fluid and particle densities and particle sizes. In space, centrifugal filtration, where particles suspended in fluid are captured by rotating fixed-fiber mat filters, is a logical candidate for mechanical separation. Non-colloidal particles are deposited on the fibers due to inertial impaction or direct interception. Since rotation rates are easily adjustable, inertial effects are the most practical way to control separation rates for a wide variety of multiphase mixtures in variable gravity environments. Understanding how fluid inertia and differential fluid-particle inertia, characterized by the Reynolds and Stokes numbers, respectively, affect deposition is critical in optimizing filtration in a microgravity environment. This work will develop non-intrusive optical diagnostic techniques for directly visualizing where and when non-colloidal particles deposit upon, or contact, solid surfaces: 'particle proximity sensors'. To model particle deposition upon a single filter fiber, these sensors will be used in ground-based experiments to study particle dynamics as in the vicinity of a large (compared with the particles) cylinder in a simply sheared (i.e., linearly-varying, zero-mean velocity profile) neutrally-buoyant, refractive-index matched solid-liquid suspension.

  8. The polarization evolution of electromagnetic waves as a diagnostic method for a motional plasma

    NASA Astrophysics Data System (ADS)

    Shahrokhi, Alireza; Mehdian, Hassan; Hajisharifi, Kamal; Hasanbeigi, Ali

    2017-12-01

    The polarization evolution of electromagnetic (EM) radiation propagating through an electron beam-ion channel system is studied in the presence of self-magnetic field. Solving the fluid-Maxwell equations to obtain the medium dielectric tensor, the Stokes vector-Mueller matrix approach is employed to determine the polarization of the launched EM wave at any point in the propagation direction, applying the space-dependent Mueller matrix on the initial polarization vector of the wave at the plasma-vacuum interface. Results show that the polarization evolution of the wave is periodic in space along the beam axis with the specified polarization wavelength. Using the obtained results, a novel diagnostic method based on the polarization evolution of the EM waves is proposed to evaluate the electron beam density and velocity. Moreover, to use the mentioned plasma system as a polarizer, the fraction of the output radiation power transmitted through a motional plasma crossed with the input polarization is calculated. The results of the present investigation will greatly contribute to design a new EM amplifier with fixed polarization or EM polarizer, as well as a new diagnostic approach for the electron beam system where the polarimetric method is employed.

  9. Challenges in pediatric chronic inflammatory demyelinating polyneuropathy.

    PubMed

    Haliloğlu, Göknur; Yüksel, Deniz; Temoçin, Cağri Mesut; Topaloğlu, Haluk

    2016-12-01

    Chronic inflammatory demyelinating neuropathy, a treatable immune-mediated disease of the peripheral nervous system is less common in childhood compared to adults. Despite different sets of diagnostic criteria, lack of a reliable biologic marker leads to challenges in diagnosis, follow-up and treatment. Our first aim was to review clinical presentation, course, response to treatment, and prognosis in our childhood patients. We also aimed to document diagnostic and therapeutic pitfalls and challenges at the bedside. Our original cohort consisted of 23 pediatric patients who were referred to us with a clinical diagnosis of chronic inflammatory demyelinating neuropathy. Seven patients reaching to an alternative diagnosis were excluded. In the remaining patients, diagnostic, treatment and follow-up data were compared in typical patients who satisfied both clinical and electrodiagnostic criteria and atypical patients who failed to meet minimal research chronic inflammatory demyelinating neuropathy electrodiagnostic requirements. Eight of 16 patients (50%) met the minimal chronic inflammatory demyelinating neuropathy research diagnostic requirements. There was only a statistically significant difference (p = 0.010) in terms of European Neuromuscular Centre childhood chronic inflammatory diagnostic mandatory clinical criteria between the two groups. Misdiagnosis due to errors in electrophysiological interpretation (100%, n = 8), cerebrospinal fluid cytoalbuminologic dissociation (100%, n = 4 and/or subjective improvement on any immunotherapy modality (80 ± 19.27%)) was frequent. Pediatric CIDP is challenging in terms of diagnostic and therapeutic pitfalls at the bedside. Diagnostic errors due to electrophysiological interpretation, cerebrospinal fluid cytoalbuminologic dissociation, and/or subjective improvement on immunotherapy should be considered. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Diagnostic Accuracy of Cerebrospinal Fluid Amyloid-β Isoforms for Early and Differential Dementia Diagnosis.

    PubMed

    Struyfs, Hanne; Van Broeck, Bianca; Timmers, Maarten; Fransen, Erik; Sleegers, Kristel; Van Broeckhoven, Christine; De Deyn, Peter P; Streffer, Johannes R; Mercken, Marc; Engelborghs, Sebastiaan

    2015-01-01

    Overlapping cerebrospinal fluid biomarkers (CSF) levels between Alzheimer's disease (AD) and non-AD patients decrease differential diagnostic accuracy of the AD core CSF biomarkers. Amyloid-β (Aβ) isoforms might improve the AD versus non-AD differential diagnosis. To determine the added diagnostic value of Aβ isoforms, Aβ(1-37), Aβ(1-38), and Aβ(1-40), as compared to the AD CSF biomarkers Aβ(1-42), T-tau, and P-tau(181P). CSF from patients with dementia due to AD (n = 50), non-AD dementias (n = 50), mild cognitive impairment due to AD (n = 50) and non-demented controls (n = 50) was analyzed with a prototype multiplex assay using MSD detection technology. The non-AD group consisted of frontotemporal dementia (FTD; n = 17), dementia with Lewy bodies (DLB; n = 17), and vascular dementia (n = 16). Aβ(1-37) and Aβ(1-38) increased accuracy to differentiate AD from FTD or DLB. Aβ(1-37), Aβ(1-38), and Aβ(1-40) levels correlated with Mini-Mental State Examination scores and disease duration in dementia due to AD. The Aβ(1-42)/Aβ(1-40) ratio improved diagnostic performance of Aβ(1-42) in most differential diagnostic situations. Aβ(1-42) levels were lower in APOE ε4 carriers compared to non-carriers. Aβ isoforms help to differentiate AD from FTD and DLB. Aβ isoforms increase diagnostic performance of Aβ(1-42). In contrast to Aβ1-42, Aβ isoforms seem to be correlated with disease severity in AD. Adding the Aβ isoforms to the current biomarker panel could enhance diagnostic accuracy.

  11. Diagnostic accuracy for apical and chronic periodontitis biomarkers in gingival crevicular fluid: an exploratory study.

    PubMed

    Baeza, Mauricio; Garrido, Mauricio; Hernández-Ríos, Patricia; Dezerega, Andrea; García-Sesnich, Jocelyn; Strauss, Franz; Aitken, Juan Pablo; Lesaffre, Emmanuel; Vanbelle, Sophie; Gamonal, Jorge; Brignardello-Petersen, Romina; Tervahartiala, Taina; Sorsa, Timo; Hernández, Marcela

    2016-01-01

    The aim of this study was to assess the levels and diagnostic accuracy of a set of potential biomarkers of periodontal tissue metabolism in gingival crevicular fluid (GCF) from patients with chronic periodontitis (CP) and asymptomatic apical periodontitis ( AAP). Thirty one GCF samples from 11 CP patients, 44 GCF samples from 38 AAP patients and 31 GCF samples from 13 healthy volunteers were obtained (N = 106). Matrix metalloproteinases (MMPs) -2 and -9 were determined by zymography; levels of MMP-8 by ELISA and IFMA and MPO by ELISA. IL-1, IL-6, TNFα, DKK-1, Osteonectin, Periostin, TRAP-5 and OPG were determined by a multiplex quantitative panel. Statistical analysis was performed using linear mixed-effects models. The MMP-9 and MMP-8 were higher in CP, followed by AAP, versus healthy individuals (p < 0.05). ProMMP-2, MPO, IL-1, IL-6, PTN, TRAP-5 and OPG were significantly higher in CP when compared with AAP and healthy patients (p < 0.05). The highest diagnostic accuracies were observed for ProMMP-2, ProMMP-9, MMP-8 and TRAP-5 (AUC > 0.97) in CP, and for the active form of MMP-9 and MMP-8 (AUC > 0.90) in AAP. Gingival crevicular fluid composition is modified by CP and AAP. MMP-9 and MMP-8 show diagnostic potential for CP and AAP, whereas MMP-2 and TRAP-5 are useful only for CP. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Gastrointestinal Diagnosis of Classical Whipple Disease: Clinical, Endoscopic, and Histopathologic Features in 191 Patients

    PubMed Central

    Günther, Ute; Moos, Verena; Offenmüller, Gabriel; Oelkers, Gerrit; Heise, Walther; Moter, Annette; Loddenkemper, Christoph; Schneider, Thomas

    2015-01-01

    Abstract Classic Whipple disease (CWD) is a systemic infection caused by Tropheryma whipplei. Different diagnostic tools have been developed over the last decades: periodic acid-Schiff (PAS) staining, T whipplei-specific polymerase chain reaction (PCR), and T whipplei-specific immunohistochemistry (IHC). Despite all these advances, CWD is still difficult to diagnose because of a variety of clinical symptoms and possibly a long time span between first unspecific symptoms and the full-blown clinical picture of the disease. Herein, we report an observational cohort study summarizing epidemiologic data, clinical manifestations, and diagnostic parameters of 191 patients with CWD collected at our institution. Gastrointestinal manifestations are the most characteristic symptoms of CWD affecting 76% of the cohort. Although the small bowel was macroscopically conspicuous in only 27% of cases, 173 (91%) patients presented with characteristic histological changes in small bowel biopsies (in 2 patients, these changes were only seen within the ileum). However, 18 patients displayed normal small bowel histology without typical PAS staining. In 9 of these patients, alternative test were positive from their duodenal specimens (ie, T whipplei-specific PCR and/or IHC). Thus, in 182 patients (95%) a diagnostic hint toward CWD was obtained from small bowel biopsies. Only 9 patients (5%) were diagnosed solely based on positive T whipplei-specific PCR and/or IHC of extraintestinal fluids (eg, cerebrospinal fluid, synovial fluid) or extraintestinal tissue (eg, lymph node, synovial tissue), respectively. Thus, despite efforts to diagnose CWD from alternative specimens, gastroscopy with duodenal biopsy and subsequent histological and molecular–biological examination is the most reliable diagnostic tool for CWD. PMID:25881849

  13. Diagnostic system for measuring temperature, pressure, CO2 concentration and H2O concentration in a fluid stream

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Partridge, Jr., William P.; Jatana, Gurneesh Singh; Yoo, Ji-Hyung

    A diagnostic system for measuring temperature, pressure, CO.sub.2 concentration and H.sub.2O concentration in a fluid stream is described. The system may include one or more probes that sample the fluid stream spatially, temporally and over ranges of pressure and temperature. Laser light sources are directed down pitch optical cables, through a lens and to a mirror, where the light sources are reflected back, through the lens to catch optical cables. The light travels through the catch optical cables to detectors, which provide electrical signals to a processer. The processer utilizes the signals to calculate CO.sub.2 concentration based on the temperaturesmore » derived from H.sub.2O vapor concentration. A probe for sampling CO.sub.2 and H.sub.2O vapor concentrations is also disclosed. Various mechanical features interact together to ensure the pitch and catch optical cables are properly aligned with the lens during assembly and use.« less

  14. A cyclostationary multi-domain analysis of fluid instability in Kaplan turbines

    NASA Astrophysics Data System (ADS)

    Pennacchi, P.; Borghesani, P.; Chatterton, S.

    2015-08-01

    Hydraulic instabilities represent a critical problem for Francis and Kaplan turbines, reducing their useful life due to increase of fatigue on the components and cavitation phenomena. Whereas an exhaustive list of publications on computational fluid-dynamic models of hydraulic instability is available, the possibility of applying diagnostic techniques based on vibration measurements has not been investigated sufficiently, also because the appropriate sensors seldom equip hydro turbine units. The aim of this study is to fill this knowledge gap and to exploit fully, for this purpose, the potentiality of combining cyclostationary analysis tools, able to describe complex dynamics such as those of fluid-structure interactions, with order tracking procedures, allowing domain transformations and consequently the separation of synchronous and non-synchronous components. This paper will focus on experimental data obtained on a full-scale Kaplan turbine unit, operating in a real power plant, tackling the issues of adapting such diagnostic tools for the analysis of hydraulic instabilities and proposing techniques and methodologies for a highly automated condition monitoring system.

  15. Diagnostic system for measuring temperature, pressure, CO.sub.2 concentration and H.sub.2O concentration in a fluid stream

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Partridge, Jr., William P.; Jatana, Gurneesh Singh; Yoo, Ji Hyung

    A diagnostic system for measuring temperature, pressure, CO.sub.2 concentration and H.sub.2O concentration in a fluid stream is described. The system may include one or more probes that sample the fluid stream spatially, temporally and over ranges of pressure and temperature. Laser light sources are directed down pitch optical cables, through a lens and to a mirror, where the light sources are reflected back, through the lens to catch optical cables. The light travels through the catch optical cables to detectors, which provide electrical signals to a processer. The processer utilizes the signals to calculate CO.sub.2 concentration based on the temperaturesmore » derived from H.sub.2O vapor concentration. A probe for sampling CO.sub.2 and H.sub.2O vapor concentrations is also disclosed. Various mechanical features interact together to ensure the pitch and catch optical cables are properly aligned with the lens during assembly and use.« less

  16. Parkinson's disease biomarker: a patent evaluation of WO2013153386.

    PubMed

    Geldenhuys, Werner J; Abdelmagid, Samir M; Gallegos, Patrick J; Safadi, Fayez F

    2014-08-01

    Parkinson's disease (PD) is a neurodegenerative movement disorder resultant from the loss of dopaminergic neurons in the brain. There is an urgent need for effective biomarkers that can be used in the early diagnosis of PD. Mitochondrial dysfunction plays a significant role in PD pathology, which has led to the evaluation of mitophagy markers, PTEN-induced putative kinase 1 (PINK1), and PARKIN as possible biomarkers for the early diagnosis of PD. The current patent describes the use of phosphorylation of PINK1 and PARKIN as a diagnostic measure. Specifically, Ser65 on PARKIN, which is phosphorylated by PINK1, and the autophosphorylation of PINK1 at Thr257 are described. This patent describes a much needed methodology that can easily be adapted in the clinical setting by which a biological sample, such as serum or cerebrospinal fluid, is collected and analyzed for the phosphorylation markers. Here, the phosphorylation activity seen in PINK1 and PARKIN can differentiate between age-matched controls and PD patients. This patent presents a novel diagnostic measure in early PD, as well as determines which medications would have a beneficial effect on a patient's disease progression.

  17. The clinical chemistry and immunology of long-duration space missions.

    PubMed

    Wu, A H; Taylor, G R; Graham, G A; McKinley, B A

    1993-01-01

    Clinical laboratory diagnostic capabilities are needed to guide health and medical care of astronauts during long-duration space missions. Clinical laboratory diagnostics, as defined for medical care on Earth, offers a model for space capabilities. Interpretation of laboratory results for health and medical care of humans in space requires knowledge of specific physiological adaptations that occur, primarily because of the absence of gravity, and how these adaptations affect reference values. Limited data from American and Russian missions have indicated shifts of intra- and extracellular fluids and electrolytes, changes in hormone concentrations related to fluid shifts and stresses of the missions, reductions in bone and muscle mass, and a blunting of the cellular immune response. These changes could increase susceptibility to space-related illness or injury during a mission and after return to Earth. We review physiological adaptations and the risk of medical problems that occur during space missions. We describe the need for laboratory diagnostics as a part of health and medical care in space, and how this capability might be delivered.

  18. Subacute sclerosing panencephalitis (SSPE) presenting as acute disseminated encephalomyelitis in a child.

    PubMed

    Goraya, Jatinder; Marks, Harold; Khurana, Divya; Legido, Agustin; Melvin, Joseph

    2009-07-01

    Subacute sclerosing panencephalitis (SSPE) typically presents with progressive mental deterioration, behavioral changes, and myoclonic jerks. Atypical presentations are not unknown and may result in diagnostic delays. A 9-year-old girl presented with poor balance and ataxia following an episode of upper respiratory tract infection. Neurological examination revealed mild hemiparesis and ataxia. Brain magnetic resonance imaging revealed scattered areas of T2 and fluid-attenuated inversion recovery hyperintensities in the white matter consistent with acute disseminated encephalomyelitis. Despite treatment with intravenous methylprednisolone, intravenous immunoglobulins, and plasmapheresis, progressive neurological worsening occurred. Later during the course of her illness, subacute sclerosing panencephalitis was suspected from the appearance of burst-suppression pattern on electroencephalogram, and the diagnosis confirmed by elevated titers of measles antibodies in cerebrospinal fluid. Physicians taking care of children need to be aware of atypical presentations of subacute sclerosing panencephalitis and must have a high index of suspicion to prevent diagnostic delays and avoid unnecessary diagnostic and therapeutic interventions.

  19. Optical microsystem for analyzing engine lubricants

    NASA Astrophysics Data System (ADS)

    Scott, Andrew J.; Mabesa, Jose R., Jr.; Gorsich, David; Rathgeb, Brian; Said, Ali A.; Dugan, Mark; Haddock, Tom F.; Bado, Philippe W.

    2004-12-01

    It is possible to dramatically improve the performance, reliability, and maintainability of vehicles and other similarly complex equipment if improved sensing and diagnostics systems are available. Each year military and commercial maintenance personnel unnecessarily replace, at scheduled intervals, significant amounts of lubricant fluids in vehicles, weapon systems, and supporting equipment. Personnel draw samples of fluids and send them to test labs for analysis to determine if replacement is necessary. Systematic use of either on-board (embedded) lubricant quality analysis capabilities will save millions of dollars each year in avoided fluid changes, saved labor, prevented damage to mechanical components while providing associated environmental benefits. This paper discusses the design, the manufacturing, and the evaluation of robust optical sensors designed to monitor the condition of industrial fluids. The sensors reported are manufactured from bulk fused silica substrates. They incorporate three-dimensional micro fluidic circuitry side-by-side with three-dimensional wave guided optical networks. The manufacturing of the optical waveguides are completed using a direct-write process based on the use of femtosecond laser pulses to locally alter the structure of the glass substrate at the nano-level. The microfluidic circuitry is produced using the same femtosecond laser based process, followed by an anisotropic wet chemical etching step. Data will be presented regarding the use of these sensors to monitor the quality of engine oil and possibly some other vehicle lubricants such as hydraulic oil.

  20. The Application of SILAC Mouse in Human Body Fluid Proteomics Analysis Reveals Protein Patterns Associated with IgA Nephropathy.

    PubMed

    Zhao, Shilin; Li, Rongxia; Cai, Xiaofan; Chen, Wanjia; Li, Qingrun; Xing, Tao; Zhu, Wenjie; Chen, Y Eugene; Zeng, Rong; Deng, Yueyi

    2013-01-01

    Body fluid proteome is the most informative proteome from a medical viewpoint. But the lack of accurate quantitation method for complicated body fluid limited its application in disease research and biomarker discovery. To address this problem, we introduced a novel strategy, in which SILAC-labeled mouse serum was used as internal standard for human serum and urine proteome analysis. The SILAC-labeled mouse serum was mixed with human serum and urine, and multidimensional separation coupled with tandem mass spectrometry (IEF-LC-MS/MS) analysis was performed. The shared peptides between two species were quantified by their SILAC pairs, and the human-only peptides were quantified by mouse peptides with coelution. The comparison for the results from two replicate experiments indicated the high repeatability of our strategy. Then the urine from Immunoglobulin A nephropathy patients treated and untreated was compared by this quantitation strategy. Fifty-three peptides were found to be significantly changed between two groups, including both known diagnostic markers for IgAN and novel candidates, such as Complement C3, Albumin, VDBP, ApoA,1 and IGFBP7. In conclusion, we have developed a practical and accurate quantitation strategy for comparison of complicated human body fluid proteome. The results from such strategy could provide potential disease-related biomarkers for evaluation of treatment.

  1. Large Scale Generation and Characterization of Anti-Human CD34 Monoclonal Antibody in Ascetic Fluid of Balb/c Mice

    PubMed Central

    Aghebati Maleki, Leili; Majidi, Jafar; Baradaran, Behzad; Abdolalizadeh, Jalal; Kazemi, Tohid; Aghebati Maleki, Ali; Sineh sepehr, Koushan

    2013-01-01

    Purpose: Monoclonal antibodies or specific antibodies are now an essential tool of biomedical research and are of great commercial and medical value. The purpose of this study was to produce large scale of monoclonal antibody against CD34 in order to diagnostic application in leukemia and purification of human hematopoietic stem/progenitor cells. Methods: For large scale production of monoclonal antibody, hybridoma cells that produce monoclonal antibody against human CD34 were injected into the peritoneum of the Balb/c mice which have previously been primed with 0.5 ml Pristane. 5 ml ascitic fluid was harvested from each mouse in two times. Evaluation of mAb titration was assessed by ELISA method. The ascitic fluid was examined for class and subclasses by ELISA mouse mAb isotyping Kit. mAb was purified from ascitic fluid by affinity chromatography on Protein A-Sepharose. Purity of monoclonal antibody was monitored by SDS -PAGE and the purified monoclonal antibody was conjugated with FITC. Results: Monoclonal antibodies with high specificity and sensitivity against human CD34 by hybridoma technology were prepared. The subclass of antibody was IgG1 and its light chain was kappa. Conclusion: The conjugated monoclonal antibody could be a useful tool for isolation, purification and characterization of human hematopoietic stem cells. PMID:24312838

  2. Pine needle abortion biomarker detected in bovine fetal fluids.

    PubMed

    Snider, Douglas B; Gardner, Dale R; Janke, Bruce H; Ensley, Steven M

    2015-01-01

    Pine needle abortion is a naturally occurring condition in free-range cattle caused by the consumption of pine needles from select species of cypress, juniper, pine, and spruce trees. Confirmatory diagnosis of pine needle abortion has previously relied on a combined case history of pine needle consumption and detection of isocupressic acid in a sample from the dam. Stable metabolites of isocupressic acid include agathic acid, dihydroagathic acid, and tetrahydroagathic acid, which have been shown to be present in the serum of mature animals for a few days following consumption of pine needles. As maternal serum is infrequently submitted for diagnosis of cattle abortions, a diagnostic assay capable of confirming isocupressic acid exposure in other matrices would be desirable. To the authors' knowledge, no previous investigations have indicated whether these stable metabolites of isocupressic acid cross the placenta or are detectable in fetal tissues. Therefore, the presence of agathic acid, dihydroagathic acid, and tetrahydroagathic acid was evaluated using gas chromatography-mass spectroscopy on fetal thoracic fluid and stomach contents collected from 2 aborted bovine fetuses with a recent herd history of pine needle consumption by the dams and a subsequent abortion outbreak in the herd. Only tetrahydroagathic acid was detected in the fetal thoracic fluid and fetal stomach contents. The current study encourages diagnosticians to collect fetal thoracic fluids to permit the detection of tetrahydroagathic acid in cases of suspected pine needle abortion. © 2014 The Author(s).

  3. Microbial community structure of hydrothermal deposits from geochemically different vent fields along the Mid-Atlantic Ridge

    USGS Publications Warehouse

    Flores, Gilberto E.; Campbell, James H.; Kirshtein, Julie D.; Meneghin, Jennifer; Podar, Mircea; Steinberg, Joshua I.; Seewald, Jeffrey S.; Tivey, Margaret Kingston; Voytek, Mary A.; Yang, Zamin K.; Reysenbach, Anna-Louise

    2011-01-01

    To evaluate the effects of local fluid geochemistry on microbial communities associated with active hydrothermal vent deposits, we examined the archaeal and bacterial communities of 12 samples collected from two very different vent fields: the basalt-hosted Lucky Strike (37°17'N, 32°16.3'W, depth 1600-1750m) and the ultramafic-hosted Rainbow (36°13'N, 33°54.1'W, depth 2270-2330m) vent fields along the Mid-Atlantic Ridge (MAR). Using multiplexed barcoded pyrosequencing of the variable region 4 (V4) of the 16S rRNA genes, we show statistically significant differences between the archaeal and bacterial communities associated with the different vent fields. Quantitative polymerase chain reaction (qPCR) assays of the functional gene diagnostic for methanogenesis (mcrA), as well as geochemical modelling to predict pore fluid chemistries within the deposits, support the pyrosequencing observations. Collectively, these results show that the less reduced, hydrogen-poor fluids at Lucky Strike limit colonization by strict anaerobes such as methanogens, and allow for hyperthermophilic microaerophiles, like Aeropyrum. In contrast, the hydrogen-rich reducing vent fluids at the ultramafic-influenced Rainbow vent field support the prevalence of methanogens and other hydrogen-oxidizing thermophiles at this site. These results demonstrate that biogeographical patterns of hydrothermal vent microorganisms are shaped in part by large scale geological and geochemical processes.

  4. Assessment of real-time PCR method for detection of EGFR mutation using both supernatant and cell pellet of malignant pleural effusion samples from non-small-cell lung cancer patients.

    PubMed

    Shin, Saeam; Kim, Juwon; Kim, Yoonjung; Cho, Sun-Mi; Lee, Kyung-A

    2017-10-26

    EGFR mutation is an emerging biomarker for treatment selection in non-small-cell lung cancer (NSCLC) patients. However, optimal mutation detection is hindered by complications associated with the biopsy procedure, tumor heterogeneity and limited sensitivity of test methodology. In this study, we evaluated the diagnostic utility of real-time PCR using malignant pleural effusion samples. A total of 77 pleural fluid samples from 77 NSCLC patients were tested using the cobas EGFR mutation test (Roche Molecular Systems). Pleural fluid was centrifuged, and separated cell pellets and supernatants were tested in parallel. Results were compared with Sanger sequencing and/or peptide nucleic acid (PNA)-mediated PCR clamping of matched tumor tissue or pleural fluid samples. All samples showed valid real-time PCR results in one or more DNA samples extracted from cell pellets and supernatants. Compared with other molecular methods, the sensitivity of real-time PCR method was 100%. Concordance rate of real-time PCR and Sanger sequencing plus PNA-mediated PCR clamping was 98.7%. We have confirmed that real-time PCR using pleural fluid had a high concordance rate compared to conventional methods, with no failed samples. Our data demonstrated that the parallel real-time PCR testing using supernatant and cell pellet could offer reliable and robust surrogate strategy when tissue is not available.

  5. Measurement of serum C-reactive protein concentration for discriminating between suppurative arthritis and osteoarthritis in dogs.

    PubMed

    Hillström, Anna; Bylin, Jonas; Hagman, Ragnvi; Björhall, Karin; Tvedten, Harold; Königsson, Kristian; Fall, Tove; Kjelgaard-Hansen, Mads

    2016-10-28

    In a dog with joint pain, it is important to determine whether it has suppurative joint disease, characterized by exudation of neutrophils in the synovial fluid, or not, as this affects choice of diagnostic tests and treatments. The aim of this study was to evaluate whether measurement of serum C-reactive protein (CRP) concentration could be used to discriminate between dogs with suppurative arthritis and osteoarthritis (OA). Furthermore, the concentrations of serum and synovial fluid interleukin (IL) 6 concentrations were measured in dogs with joint disease and in healthy dogs, and were correlated to serum CRP concentrations. Dogs with joint pain were enrolled prospectively and were classified to have suppurative arthritis or OA based on synovial fluid analysis and radiographic/arthroscopic findings. Healthy Beagles were enrolled as a comparative group. CRP and IL-6 concentrations were measured with canine-specific immunoassays. The performance of CRP concentration in discriminating between dogs with suppurative arthritis and OA was evaluated using a previously established clinical decision limit for CRP (20 mg/l), and by receiver operator characteristic (ROC) curve and logistic regression analysis. Comparisons of CRP and IL-6 concentrations between groups were performed using t-tests, and correlations by Spearman rank correlation coefficients. Samples were obtained from 31 dogs with suppurative arthritis, 34 dogs with OA, and 17 healthy dogs. Sixty-two out of 65 dogs with joint disease were correctly classified using the clinical decision limit for CRP. Evaluation of ROC curve and regression analysis indicated that serum CRP concentrations could discriminate between suppurative arthritis and OA. Dogs with suppurative arthritis had higher serum CRP and serum and synovial fluid IL-6 concentrations compared to dogs with OA (p < 0.001). Dogs with OA had higher synovial fluid IL-6 concentrations (p < 0.001), but not higher serum CRP (p = 0.29) or serum IL-6 (p = 0.07) concentrations, compared to healthy dogs. There was a positive correlation between synovial fluid IL-6 and serum CRP concentrations (r s  = 0.733, p < 0.001), and between serum IL-6 and serum CRP concentrations (r s  = 0.729, p < 0.001). CRP concentration was found to discriminate well between dogs with suppurative arthritis and OA.

  6. Mass spectrometric profiling of low-molecular-weight volatile compounds--diagnostic potential and latest applications.

    PubMed

    Lechner, Matthias; Rieder, Josef

    2007-01-01

    The theoretical use of mass spectrometric profiling of low-molecular-weight volatile compounds, as one possible method to non-invasively and rapidly diagnose a variety of diseases, such as cancer, infection, and metabolic disorders has greatly raised the profile of this technique over the last ten years. Despite a number of promising results, this technique has not been introduced into common clinical practice yet. The use of mass spectrometric profiling of exhaled air is particularly hampered by various technical problems and basic methodological issues which have only been partially overcome. However, breath analysis aside, recently published studies reveal completely new ideas and concepts on how to establish fast and reliable diagnosis by using this valuable tool. These studies focussed on the headspace screening of various bodily fluids and sample fluids obtained during diagnostic procedures, as well as microbial cell cultures and demonstrated the vast diagnostic potential of this technique in a wide variety of settings, predominantly in vitro. It is the aim of the present review to discuss the most commonly detected low-molecular-weight volatile compounds and to summarize the current potential applications, latest developments and future perspectives of this promising diagnostic approach.

  7. Magnetohydrodynamic pump with a system for promoting flow of fluid in one direction

    DOEpatents

    Lemoff, Asuncion V [Union City, CA; Lee, Abraham P [Irvine, CA

    2010-07-13

    A magnetohydrodynamic pump for pumping a fluid. The pump includes a microfluidic channel for channeling the fluid, a MHD electrode/magnet system operatively connected to the microfluidic channel, and a system for promoting flow of the fluid in one direction in the microfluidic channel. The pump has uses in the medical and biotechnology industries for blood-cell-separation equipment, biochemical assays, chemical synthesis, genetic analysis, drug screening, an array of antigen-antibody reactions, combinatorial chemistry, drug testing, medical and biological diagnostics, and combinatorial chemistry. The pump also has uses in electrochromatography, surface micromachining, laser ablation, inkjet printers, and mechanical micromilling.

  8. [DIAGNOSTIC VALUE OF COMBINED USE OF COMBINED METHOD OF ENZYME IMMUNOASSAY AND POLYMERASE CHAIN REACTION TO DETECT OF INTRAUTERINE FETAL INFECTION BY PARVOVIRUS B19].

    PubMed

    Bondarenko, N P; Lakatosh, V P; Lakatosh, P V; Malanchuk, O B; Poladich, I V

    2015-01-01

    The combined method of diagnosis parvovirus infection during pregnancy by maternal serum enzyme immunoassay and deoxyribonucleic acid isolation parvovirus B19 polymerase chain reaction in amnniotic fluid and fetal cord blood newborns, can diagnose vertical transmission and anticipate a negative effect on the fetus parvovirus. Lack of maternal IgM antibodies in serum due to parvovirus seroconversion during pregnancy does not exclude the persistence of the virus in the fetus. To analyze the diagnostic value of the method for determining the LHP parvovirus B19 DNA in the amniotic fluid, umbilical cord blood of newborns to determine vertical transmission of parvovirus infection when infected mothers B19 during pregnancy.

  9. [Cerebrospinal fluid diagnostics in Germany since 1950 : Developments in the GDR and FRG in the context of society and science].

    PubMed

    Reiber, H

    2016-12-01

    The 40 years of separated development in two countries with extremely different political and social utopias allow consideration of the connection between science and society. The society-dependent development of cerebrospinal fluid (CSF) diagnostics in the German Democratic Republic (GDR) and the Federal Republic of Germany (FRG) is shown in the context of the international scientific development of the post-war era with new paradigms in physics, biology and genetics. As part of this contribution to the philosophy of science the consequences of the complex life science for a new view of disease research are discussed in contrast to the currently dominating, reductionistic medical industrial complex.

  10. Fecal electrolyte testing for evaluation of unexplained diarrhea: Validation of body fluid test accuracy in the absence of a reference method.

    PubMed

    Voskoboev, Nikolay V; Cambern, Sarah J; Hanley, Matthew M; Giesen, Callen D; Schilling, Jason J; Jannetto, Paul J; Lieske, John C; Block, Darci R

    2015-11-01

    Validation of tests performed on body fluids other than blood or urine can be challenging due to the lack of a reference method to confirm accuracy. The aim of this study was to evaluate alternate assessments of accuracy that laboratories can rely on to validate body fluid tests in the absence of a reference method using the example of sodium (Na(+)), potassium (K(+)), and magnesium (Mg(2+)) testing in stool fluid. Validations of fecal Na(+), K(+), and Mg(2+) were performed on the Roche cobas 6000 c501 (Roche Diagnostics) using residual stool specimens submitted for clinical testing. Spiked recovery, mixing studies, and serial dilutions were performed and % recovery of each analyte was calculated to assess accuracy. Results were confirmed by comparison to a reference method (ICP-OES, PerkinElmer). Mean recoveries for fecal electrolytes were Na(+) upon spiking=92%, mixing=104%, and dilution=105%; K(+) upon spiking=94%, mixing=96%, and dilution=100%; and Mg(2+) upon spiking=93%, mixing=98%, and dilution=100%. When autoanalyzer results were compared to reference ICP-OES results, Na(+) had a slope=0.94, intercept=4.1, and R(2)=0.99; K(+) had a slope=0.99, intercept=0.7, and R(2)=0.99; and Mg(2+) had a slope=0.91, intercept=-4.6, and R(2)=0.91. Calculated osmotic gap using both methods were highly correlated with slope=0.95, intercept=4.5, and R(2)=0.97. Acid pretreatment increased magnesium recovery from a subset of clinical specimens. A combination of mixing, spiking, and dilution recovery experiments are an acceptable surrogate for assessing accuracy in body fluid validations in the absence of a reference method. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  11. Airside HVAC BESTEST. Adaptation of ASHRAE RP 865 Airside HVAC Equipment Modeling Test Cases for ASHRAE Standard 140. Volume 1, Cases AE101-AE445

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Neymark, J.; Kennedy, M.; Judkoff, R.

    This report documents a set of diagnostic analytical verification cases for testing the ability of whole building simulation software to model the air distribution side of typical heating, ventilating and air conditioning (HVAC) equipment. These cases complement the unitary equipment cases included in American National Standards Institute (ANSI)/American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE) Standard 140, Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs, which test the ability to model the heat-transfer fluid side of HVAC equipment.

  12. Distinct phenotype clusters in childhood inflammatory brain diseases: implications for diagnostic evaluation.

    PubMed

    Cellucci, Tania; Tyrrell, Pascal N; Twilt, Marinka; Sheikh, Shehla; Benseler, Susanne M

    2014-03-01

    To identify distinct clusters of children with inflammatory brain diseases based on clinical, laboratory, and imaging features at presentation, to assess which features contribute strongly to the development of clusters, and to compare additional features between the identified clusters. A single-center cohort study was performed with children who had been diagnosed as having an inflammatory brain disease between June 1, 1989 and December 31, 2010. Demographic, clinical, laboratory, neuroimaging, and histologic data at diagnosis were collected. K-means cluster analysis was performed to identify clusters of patients based on their presenting features. Associations between the clusters and patient variables, such as diagnoses, were determined. A total of 147 children (50% female; median age 8.8 years) were identified: 105 with primary central nervous system (CNS) vasculitis, 11 with secondary CNS vasculitis, 8 with neuronal antibody syndromes, 6 with postinfectious syndromes, and 17 with other inflammatory brain diseases. Three distinct clusters were identified. Paresis and speech deficits were the most common presenting features in cluster 1. Children in cluster 2 were likely to present with behavior changes, cognitive dysfunction, and seizures, while those in cluster 3 experienced ataxia, vision abnormalities, and seizures. Lesions seen on T2/fluid-attenuated inversion recovery sequences of magnetic resonance imaging were common in all clusters, but unilateral ischemic lesions were more prominent in cluster 1. The clusters were associated with specific diagnoses and diagnostic test results. Children with inflammatory brain diseases presented with distinct phenotypical patterns that are associated with specific diagnoses. This information may inform the development of a diagnostic classification of childhood inflammatory brain diseases and suggest that specific pathways of diagnostic evaluation are warranted. Copyright © 2014 by the American College of Rheumatology.

  13. Influenza A Virus Surveillance Based on Pre-Weaning Piglet Oral Fluid Samples.

    PubMed

    Panyasing, Y; Goodell, C; Kittawornrat, A; Wang, C; Levis, I; Desfresne, L; Rauh, R; Gauger, P C; Zhang, J; Lin, X; Azeem, S; Ghorbani-Nezami, S; Yoon, K-J; Zimmerman, J

    2016-10-01

    Influenza A virus (IAV) surveillance using pre-weaning oral fluid samples from litters of piglets was evaluated in four ˜12 500 sow and IAV-vaccinated, breeding herds. Oral fluid samples were collected from 600 litters and serum samples from their dams at weaning. Litter oral fluid samples were tested for IAV by virus isolation, quantitative reverse transcription-polymerase chain reaction (qRT-PCR), RT-PCR subtyping and sequencing. Commercial nucleoprotein (NP) enzyme-linked immunosorbent assay (ELISA) kits and NP isotype-specific assays (IgM, IgA and IgG) were used to characterize NP antibody in litter oral fluid and sow serum. All litter oral fluid specimens (n = 600) were negative by virus isolation. Twenty-five oral fluid samples (25/600 = 4.2%) were qRT-PCR positive based on screening (Laboratory 1) and confirmatory testing (Laboratory 2). No hemagglutinin (HA) and neuraminidase (NA) gene sequences were obtained, but matrix (M) gene sequences were obtained for all qRT-PCR-positive samples submitted for sequencing (n = 18). Genetic analysis revealed that all M genes sequences were identical (GenBank accession no. KF487544) and belonged to the triple reassortant influenza A virus M gene (TRIG M) previously identified in swine. The proportion of IgM- and IgA-positive samples was significantly higher in sow serum and litter oral fluid samples, respectively (P < 0.01). Consistent with the extensive use of IAV vaccine, no difference was detected in the proportion of IgG- and blocking ELISA-positive sow serum and litter oral fluids. This study supported the use of oral fluid sampling as a means of conducting IAV surveillance in pig populations and demonstrated the inapparent circulation of IAV in piglets. Future work on IAV oral fluid diagnostics should focus on improved procedures for virus isolation, subtyping and sequencing of HA and NA genes. The role of antibody in IAV surveillance remains to be elucidated, but longitudinal assessment of specific antibody has the potential to provide information regarding patterns of infection, vaccination status and herd immunity. © 2014 Blackwell Verlag GmbH.

  14. Wavelet analysis of polarization maps of polycrystalline biological fluids networks

    NASA Astrophysics Data System (ADS)

    Ushenko, Y. A.

    2011-12-01

    The optical model of human joints synovial fluid is proposed. The statistic (statistic moments), correlation (autocorrelation function) and self-similar (Log-Log dependencies of power spectrum) structure of polarization two-dimensional distributions (polarization maps) of synovial fluid has been analyzed. It has been shown that differentiation of polarization maps of joint synovial fluid with different physiological state samples is expected of scale-discriminative analysis. To mark out of small-scale domain structure of synovial fluid polarization maps, the wavelet analysis has been used. The set of parameters, which characterize statistic, correlation and self-similar structure of wavelet coefficients' distributions of different scales of polarization domains for diagnostics and differentiation of polycrystalline network transformation connected with the pathological processes, has been determined.

  15. Real-Time Polymerase Chain Reaction Detection of Angiostrongylus cantonensis DNA in Cerebrospinal Fluid from Patients with Eosinophilic Meningitis

    PubMed Central

    Qvarnstrom, Yvonne; Xayavong, Maniphet; da Silva, Ana Cristina Aramburu; Park, Sarah Y.; Whelen, A. Christian; Calimlim, Precilia S.; Sciulli, Rebecca H.; Honda, Stacey A. A.; Higa, Karen; Kitsutani, Paul; Chea, Nora; Heng, Seng; Johnson, Stuart; Graeff-Teixeira, Carlos; Fox, LeAnne M.; da Silva, Alexandre J.

    2016-01-01

    Angiostrongylus cantonensis is the most common infectious cause of eosinophilic meningitis. Timely diagnosis of these infections is difficult, partly because reliable laboratory diagnostic methods are unavailable. The aim of this study was to evaluate the usefulness of a real-time polymerase chain reaction (PCR) assay for the detection of A. cantonensis DNA in human cerebrospinal fluid (CSF) specimens. A total of 49 CSF specimens from 33 patients with eosinophilic meningitis were included: A. cantonensis DNA was detected in 32 CSF specimens, from 22 patients. Four patients had intermittently positive and negative real-time PCR results on subsequent samples, indicating that the level of A. cantonensis DNA present in CSF may fluctuate during the course of the illness. Immunodiagnosis and/or supplemental PCR testing supported the real-time PCR findings for 30 patients. On the basis of these observations, this real-time PCR assay can be useful to detect A. cantonensis in the CSF from patients with eosinophilic meningitis. PMID:26526920

  16. The future of blood-based biomarkers for Alzheimer’s disease

    PubMed Central

    Henriksen, Kim; O’Bryant, Sid E.; Hampel, Harald; Trojanowski, John Q.; Montine, Thomas J.; Jeromin, Andreas; Blennow, Kaj; Lönneborg, Anders; Wyss-Coray, Tony; Soares, Holly; Bazenet, Chantal; Sjögren, Magnus; Hu, William; Lovestone, Simon; Karsdal, Morten A.; Weiner, Michael W.

    2014-01-01

    Treatment of Alzheimer’s disease (AD) is significantly hampered by the lack of easily accessible biomarkers that can detect disease presence and predict disease risk reliably. Fluid biomarkers of AD currently provide indications of disease stage; however, they are not robust predictors of disease progression or treatment response, and most are measured in cerebrospinal fluid, which limits their applicability. With these aspects in mind, the aim of this article is to underscore the concerted efforts of the Blood-Based Biomarker Interest Group, an international working group of experts in the field. The points addressed include: (1) the major challenges in the development of blood-based biomarkers of AD, including patient heterogeneity, inclusion of the “right” control population, and the blood– brain barrier; (2) the need for a clear definition of the purpose of the individual markers (e.g., prognostic, diagnostic, or monitoring therapeutic efficacy); (3) a critical evaluation of the ongoing biomarker approaches; and (4) highlighting the need for standardization of preanalytical variables and analytical methodologies used by the field. PMID:23850333

  17. Lumbosacral Radiculoplexopathy as the Initial Presentation of Lymphoma: A Report of 4 Cases.

    PubMed

    Marquardt, Robert J; Li, Yuebing

    2018-06-01

    To evaluate the clinical, laboratory, and radiological features of 4 cases of biopsy-proven lymphomatous lumbosacral radiculoplexopathy. Retrospective chart review. All patients suffered from diffuse large B-cell lymphoma. A mean diagnostic delay of 10 months was encountered. Presenting symptoms in all 4 patients included back pain, radicular leg pain, and leg weakness, similar to spondylotic radiculopathy. Electrodiagnostic study showed axon loss radiculoplexopathy and magnetic resonance imaging of the lumbar spine or pelvis demonstrated nerve or nerve root enhancement. Increased uptake by lumbosacral roots/plexus on fluorodeoxyglucose-positron emission tomography aided diagnosis in 3 cases. Cytology was positive in 1 of 10 cerebrospinal fluid samples. Combined chemotherapy and radiation treatment led to clinicoradiological improvement, with residual neurological symptoms in all patients. Lymphomatous lumbosacral radiculoplexopathy should be considered in patients with progressive lumbosacral radicular symptoms. Magnetic resonance imaging and fluorodeoxyglucose-positron emission tomography, but not cerebrospinal fluid, are helpful in achieving early diagnosis. Treatment responses seem favorable.

  18. Nonintrusive diagnosis of premature ruptured amniotic membranes using a novel polymer.

    PubMed

    Bornstein, Jacob; Geva, Adam; Solt, Ido; Fait, Vladimir; Schoenfeld, Alex; Shoham, Hadar Kessary; Sobel, Jack

    2006-08-01

    This article describes the evaluation of the diagnostic efficacy of AL-SENSE panty-liner in detecting premature rupture of membranes (PROM). One hundred and three women attending the labor and delivery ward were enrolled into three groups: women presenting with a vaginal leak of fluid who had not yet been examined; women with overt PROM, and women with no fluid leak. The result of the AL-SENSE strip test was compared with the clinical diagnosis, which was based on direct visualization of the posterior vaginal fornix and cervix, crystallization, and nitrazine tests. AL-SENSE panty-liner test had a sensitivity of 100% and a specificity of 75% in detecting PROM, with an overall agreement of 82.35% between the AL-SENSE test result and the clinical diagnosis. AL-SENSE may be used as a reliable test to rule out PROM and as an effective device to diagnose PROM and differentiate it from urine leak and vulvovaginal candidiasis.

  19. Diagnosis of multiple system atrophy

    PubMed Central

    Palma, Jose-Alberto; Norcliffe-Kaufmann, Lucy; Kaufmann, Horacio

    2017-01-01

    Multiple system atrophy (MSA) may be difficult to distinguish clinically from other disorders, particularly in the early stages of the disease. An autonomic-only presentation can be indistinguishable from pure autonomic failure. Patients presenting with parkinsonism may be misdiagnosed as having Parkinson disease. Patients presenting with the cerebellar phenotype of MSA can mimic other adult-onset ataxias due to alcohol, chemotherapeutic agents, lead, lithium, and toluene, or vitamin E deficiency, as well as paraneoplastic, autoimmune, or genetic ataxias. A careful medical history and meticulous neurological examination remain the cornerstone for the accurate diagnosis of MSA. Ancillary investigations are helpful to support the diagnosis, rule out potential mimics, and define therapeutic strategies. This review summarizes diagnostic investigations useful in the differential diagnosis of patients with suspected MSA. Currently used techniques include structural and functional brain imaging, cardiac sympathetic imaging, cardiovascular autonomic testing, olfactory testing, sleep study, urological evaluation, and dysphagia and cognitive assessments. Despite advances in the diagnostic tools for MSA in recent years and the availability of consensus criteria for clinical diagnosis, the diagnostic accuracy of MSA remains sub-optimal. As other diagnostic tools emerge, including skin biopsy, retinal biomarkers, blood and cerebrospinal fluid biomarkers, and advanced genetic testing, a more accurate and earlier recognition of MSA should be possible, even in the prodromal stages. This has important implications as misdiagnosis can result in inappropriate treatment, patient and family distress, and erroneous eligibility for clinical trials of disease-modifying drugs. PMID:29111419

  20. Microscope-Based Fluid Physics Experiments in the Fluids and Combustion Facility on ISS

    NASA Technical Reports Server (NTRS)

    Doherty, Michael P.; Motil, Susan M.; Snead, John H.; Malarik, Diane C.

    2000-01-01

    At the NASA Glenn Research Center, the Microgravity Science Program is planning to conduct a large number of experiments on the International Space Station in both the Fluid Physics and Combustion Science disciplines, and is developing flight experiment hardware for use within the International Space Station's Fluids and Combustion Facility. Four fluids physics experiments that require an optical microscope will be sequentially conducted within a subrack payload to the Fluids Integrated Rack of the Fluids and Combustion Facility called the Light Microscopy Module, which will provide the containment, changeout, and diagnostic capabilities to perform the experiments. The Light Microscopy Module is planned as a fully remotely controllable on-orbit microscope facility, allowing flexible scheduling and control of experiments within International Space Station resources. This paper will focus on the four microscope-based experiments, specifically, their objectives and the sample cell and instrument hardware to accommodate their requirements.

  1. Accuracy of Neck stiffness, Kernig, Brudzinski, and Jolt Accentuation of Headache Signs in Early Detection of Meningitis

    PubMed Central

    Ala, Alireza; Rahmani, Farzad; Abdollahi, Sima; Parsian, Zahra

    2018-01-01

    Introduction: The diagnostic value of clinical signs in early diagnosis of meningitis has been evaluated but the existing results are contradicting. The present study aimed to evaluate the accuracy of Kernig, Brudzinski, neck stiffness, and Jolt Accentuation of Headache (JAH) signs in this regard. Methods: In this diagnostic accuracy study, patients with suspected meningitis who were referred to the emergency department were examined regarding presence or absence of the mentioned clinical signs and screening performance characteristics of the signs were calculated. Cerebrospinal fluid analysis was used as the reference test. Results: 120 cases with mean age of 48.79 ± 21.68 years (18 – 93) were studied (63.3% male). Diagnosis of meningitis was confirmed for 45 (37.5%) cases. Neck stiffness (p < 0.001), Kernig (p < 0.001), Brudzinski (p < 0.001), and JAH (p < 0.001) had significantly higher frequency among patients with meningitis. The accuracy of neck stiffness, Kernig, Brudzinski, and JAH signs in early detection of meningitis were 0.676 (95% CI: 0.575-0.776), 0.667 (95% CI: 0.552-0.782), 0.720 (95% CI: 0.619-0.821), 0.749 (95% CI: 0.659-839), respectively. Conclusions: It seems that diagnostic value of JAH is higher than other clinical signs but the accuracy of all signs is in poor to fair range. JAH had the highest sensitivity and Kernig and Brudzinski had the highest specificity. PMID:29503833

  2. Monitoring Changes in Hepatic Venous Velocities Flow after a Fluid Challenge Can Identify Shock Patients Who Lack Fluid Responsiveness

    PubMed Central

    Du, Wei; Wang, Xiao-Ting; Long, Yun; Liu, Da-Wei

    2017-01-01

    Background: Evaluating the hemodynamic status and predicting fluid responsiveness are important in critical ultrasound assessment of shock patients. Transthoracic echocardiography with noninvasive diagnostic parameters allows the assessment of volume responsiveness. This study aimed to assess the hemodynamic changes in the liver and systemic hemodynamic changes during fluid challenge and during passive leg raising (PLR) by measuring hepatic venous flow (HVF) velocity. Methods: This is an open-label study in a tertiary teaching hospital. Shock patients with hypoperfusion who required fluid challenge were selected for the study. Patients <18 years old and those with contraindications to PLR were excluded from the study. Baseline values were measured, PLR tests were performed, and 500 ml of saline was infused over 30 min. Parameters associated with cardiac output (CO) in the left ventricular outflow tract were measured using the Doppler method. In addition, HVF velocity and right ventricular function parameters were determined. Results: Middle hepatic venous (MHV) S-wave velocity was positively correlated in all patients with CO at baseline (r = 0.706, P < 0.01) and after volume expansion (r = 0.524, P = 0.003). CO was also significantly correlated with MHV S-wave velocity in responders (r = 0.608, P < 0.01). During PLR, however, hepatic venous S-wave velocity did not correlate with CO. For the parameter ΔMHV D (increase in change in MHV D-wave velocity after volume expansion), defined as (MHV DafterVE − MHV DBaseline)/MHV DBaseline × 100%, >21% indicated no fluid responsiveness, with a sensitivity of 100%, a specificity of 71.2%, and an area under the receiver operating characteristic curve of 0.918. Conclusions: During fluid expansion, hepatic venous S-wave velocity can be used to monitor CO, whether or not it is increasing. ΔMHV D ≥21% indicated a lack of fluid responsiveness, thus helping to decide when to stop infusions. PMID:28485321

  3. Diagnostic and Prognostic Values of Monocyte Chemotactic Protein-1 in Ascitic Fluid of Patients with Spontaneous Bacterial Peritonitis.

    PubMed

    El-Toukhy, Naglaa; Emam, Sherin M

    2016-06-01

    Spontaneous bacterial peritonitis (SBP) is a severe complication in cirrhotics with ascites. Monocyte chemotactic protien-1 (MCP-1) is a chemotactic factor for monocytes/macrophages, and it activates lymphocytes and neutrophils during infection. This study aimed to evaluate the role of MPC-1 in the pathogenesis of SBP and assess its prognostic value and correlation to disease severity. The study included ninety patients with liver cirrhosis and ascites. Patients were divided into 2 groups: Group I including 45 ascetic patients with SBP (polymorph nuclear cell count (PMN) >= 250 cell/mm3 in ascitic fluid), and Group II including 45 ascetic patients without SBP. Assessment of the severity of liver cirrhosis was done using the modified Child-Pugh and model for end stage liver disease (MELD) scores. Ascetic fluid samples were subjected to total leucocytic count and differential, albumin, protein, glucose, and serum-ascetic albumin gradient analysis Ascetic fluid levels of (MCP-1was measured by ELISA. Higher level was detected in patients with SBP as compared to those without SBP. The number of polymorph nuclear cell count (PMN) >= 250 cell/mm3 in ascitic fluid) was used as gold standard for diagnosis of SBP. The diagnosis sensitivity and specificity of MCP level test were 86.7% and 95.4% respectively at cutoff of122.5ng/ml with accuracy 91%. MCP-1 level showed positive significant correlation with TLC, PMN leucocytes and MELD score. In conclusion, ascitic fluid MCP-1 level could be a reliable test for diagnosis of SBP, and could be used as a prognostic marker due to its positive correlation with the severity of liver disease. Copyright© by the Egyptian Association of Immunologists.

  4. Vitrectomy for the diagnosis and management of uveitis of unknown cause.

    PubMed

    Margolis, Ron; Brasil, Oswaldo F M; Lowder, Careen Y; Singh, Rishi P; Kaiser, Peter K; Smith, Scott D; Perez, Victor L; Sonnie, Christine; Sears, Jonathan E

    2007-10-01

    To determine the diagnostic yield of tests commonly used for vitreous fluid analysis in eyes with suspected intraocular infection or malignancy. Noncomparative interventional case series. Forty-four consecutive patients (45 eyes) treated from 1998 through 2006 with posterior segment inflammation who underwent pars plana vitrectomy for diagnostic purposes. Vitreous specimens obtained via pars plana vitrectomy were analyzed by microbiologic culture, cytologic analysis, and flow cytometry. Diagnostic yield and sensitivity of each test performed on vitreous specimens and visual outcomes of eyes that underwent diagnostic vitrectomy (DVx). Preoperative diagnoses were infection in 15 eyes and malignancy in 30 eyes. Overall, vitreous analysis identified a specific cause in 9 (20%) of 45 eyes. The overall sensitivity of DVx was 63.6%. The sensitivities of individual tests were: culture, 50%; cytologic analysis, 66.7%; and flow cytometry, 83.3%. The yields of diagnostic tests were: culture, 5.7%; cytologic analysis, 14.3%; and flow cytometry, 20.6%. Final diagnoses were infection in 6 eyes, malignancy in 9 eyes, and idiopathic in 30 eyes. Mean visual acuity improved significantly in the first 6 months after DVx. Visual acuity improved in 60% of eyes, with 37.8% of eyes improving by 3 lines or more. Analysis of vitreous fluid by widely available tests is useful in identifying intraocular infection or malignancy. Most patients experienced a substantial improvement in vision.

  5. Diagnostic value of N-terminal pro-brain natriuretic peptide for pleural effusion due to heart failure: a meta-analysis.

    PubMed

    Zhou, Q; Ye, Z J; Su, Y; Zhang, J C; Shi, H Z

    2010-08-01

    N-terminal pro-brain natriuretic peptide (NT-proBNP) is a biomarker useful in diagnosis of pleural effusion due to heart failure. Thus far, its overall diagnostic accuracy has not been systematically reviewed. The aim of the present meta-analysis was to establish the overall diagnostic accuracy of the measurement of pleural NT-proBNP for identifying pleural effusion due to heart failure. After a systematic review of English-language studies, sensitivity, specificity, and other measures of accuracy of NT-proBNP concentrations in pleural fluid in the diagnosis of pleural effusion resulting from heart failure were pooled using fixed-effects models. Summary receiver operating characteristic curves were used to summarise overall test performance. Eight publications met the inclusion criteria. The summary estimates for pleural NT-proBNP in the diagnosis of pleural effusion attributable to heart failure were: sensitivity 0.95 (95% CI 0.92 to 0.97), specificity 0.94 (0.92 to 0.96), positive likelihood ratio 14.12 (10.23 to 19.51), negative likelihood ratio 0.06 (0.04 to 0.09) and diagnostic OR 213.87 (122.50 to 373.40). NT-proBNP levels in pleural fluid showed a high diagnostic accuracy and may help accurately differentiate cardiac from non-cardiac conditions in patients presenting with pleural effusion.

  6. Saliva Preservative for Diagnostic Purposes

    NASA Technical Reports Server (NTRS)

    Pierson, Duane L.; Mehta, Satish K.

    2012-01-01

    Saliva is an important body fluid for diagnostic purposes. Glycoproteins, glucose, steroids, DNA, and other molecules of diagnostic value are found in saliva. It is easier to collect as compared to blood or urine. Unfortunately, saliva also contains large numbers of bacteria that can release enzymes, which can degrade proteins and nucleic acids. These degradative enzymes destroy or reduce saliva s diagnostic value. This innovation describes the formulation of a chemical preservative that prevents microbial growth and inactivates the degradative enzymes. This extends the time that saliva can be stored or transported without losing its diagnostic value. Multiple samples of saliva can be collected if needed without causing discomfort to the subject and it does not require any special facilities to handle after it is collected.

  7. Proteomic Changes of Alveolar Lining Fluid in Illnesses Associated with Exposure to Inhaled Non-Infectious Microbial Particles

    PubMed Central

    Teirilä, Laura; Karvala, Kirsi; Ahonen, Niina; Riska, Henrik; Pietinalho, Anne; Tuominen, Päivi; Piirilä, Päivi

    2014-01-01

    Background Hyperresponsiveness to inhaled non-infectious microbial particles (NIMPs) has been associated with illnesses in the airways. Hypersensitivity pneumonitis (HP) is considered to be the prototype for these NIMPs-related diseases; however, there is no consensus on the definitions or diagnostic criteria for HP and the spectrum of related illnesses. Methods and Findings In order to identify the possible diagnostic markers for illnesses associated with NIMPs in alveolar lining fluid, we performed a proteomic analysis using a two-dimensional difference gel electrophoresis on bronchoalveolar lavage (BAL) fluid from patients with exposure to NIMPs in the context of damp building-related illness (DBRI) or conditions on the borderline to acute HP, designated here as agricultural type of microbial exposure (AME). Samples from patients with HP and sarcoidosis (SARC) were included for reference. Results were compared to results of healthy subjects (CTR). Western blot was used for validation of potential marker proteins from BAL fluid and plasma. Protein expression patterns suggest a close similarity between AME and HP, while DBRI was similar to CTR. However, in DBRI the levels of the inflammation associated molecules galectin-3 and alpha-1-antitrypsin were increased. A novel finding emerging from this study was the increases of semenogelin levels in BAL fluid from patients with AME, HP and SARC. Histone 4 levels were increased in AME, HP and SARC. Elevated plasma levels of histone 2B were detected in HP and SARC, suggesting it to be a potential blood indicator for inflammatory diseases of the lungs. Conclusions In this study, the proteomic changes in bronchoalveolar lavage of DBRI patients were distinct from other NIMP exposure associated lung diseases, while changes in AME overlapped those observed for HP patient samples. Some of the proteins identified in this study, semenogelin and histone 4, could function as diagnostic markers for differential diagnosis between DBRI and HP-like conditions. PMID:25033447

  8. Molecular Diagnosis of Orthopedic-Device-Related Infection Directly from Sonication Fluid by Metagenomic Sequencing

    PubMed Central

    Sanderson, Nicholas D.; Atkins, Bridget L.; Brent, Andrew J.; Cole, Kevin; Foster, Dona; McNally, Martin A.; Oakley, Sarah; Peto, Leon; Taylor, Adrian; Peto, Tim E. A.; Crook, Derrick W.; Eyre, David W.

    2017-01-01

    ABSTRACT Culture of multiple periprosthetic tissue samples is the current gold standard for microbiological diagnosis of prosthetic joint infections (PJI). Additional diagnostic information may be obtained through culture of sonication fluid from explants. However, current techniques can have relatively low sensitivity, with prior antimicrobial therapy and infection by fastidious organisms influencing results. We assessed if metagenomic sequencing of total DNA extracts obtained direct from sonication fluid can provide an alternative rapid and sensitive tool for diagnosis of PJI. We compared metagenomic sequencing with standard aerobic and anaerobic culture in 97 sonication fluid samples from prosthetic joint and other orthopedic device infections. Reads from Illumina MiSeq sequencing were taxonomically classified using Kraken. Using 50 derivation samples, we determined optimal thresholds for the number and proportion of bacterial reads required to identify an infection and confirmed our findings in 47 independent validation samples. Compared to results from sonication fluid culture, the species-level sensitivity of metagenomic sequencing was 61/69 (88%; 95% confidence interval [CI], 77 to 94%; for derivation samples 35/38 [92%; 95% CI, 79 to 98%]; for validation samples, 26/31 [84%; 95% CI, 66 to 95%]), and genus-level sensitivity was 64/69 (93%; 95% CI, 84 to 98%). Species-level specificity, adjusting for plausible fastidious causes of infection, species found in concurrently obtained tissue samples, and prior antibiotics, was 85/97 (88%; 95% CI, 79 to 93%; for derivation samples, 43/50 [86%; 95% CI, 73 to 94%]; for validation samples, 42/47 [89%; 95% CI, 77 to 96%]). High levels of human DNA contamination were seen despite the use of laboratory methods to remove it. Rigorous laboratory good practice was required to minimize bacterial DNA contamination. We demonstrate that metagenomic sequencing can provide accurate diagnostic information in PJI. Our findings, combined with the increasing availability of portable, random-access sequencing technology, offer the potential to translate metagenomic sequencing into a rapid diagnostic tool in PJI. PMID:28490492

  9. Central nervous system Aspergillus infection after epidural analgesia: diagnosis, therapeutic challenges, and literature review

    PubMed Central

    Genzen, Jonathan R.; Kenney, Barton

    2009-01-01

    Aspergillus terreus was identified in an intra-dural spinal biopsy specimen from an African female with recurrent headache and hydrocephalus. Prior laboratory testing of cerebrospinal fluid (CSF) was non-diagnostic, despite extensive central nervous system (CNS) involvement. CNS Aspergillus infection presents a diagnostic and therapeutic challenge and is reviewed in the context of this particularly instructive and difficult case. PMID:19717262

  10. Potential Clinical Impact of The Filmarray Meningitis Encephalitis Panel In Children With Suspected Central Nervous System Infections

    PubMed Central

    Messacar, Kevin; Breazeale, Garrett; Robinson, Christine C.; Dominguez, Samuel R.

    2016-01-01

    The FilmArray Meningitis Encephalitis Panel, a multiplex PCR for testing of cerebrospinal fluid, was compared to conventional diagnostic methods in children with suspected central nervous system infections. The panel had comparable diagnostic yield (96% agreement) and improved time-to-diagnosis by 10.3 hours with potential for more judicious antimicrobial use, particularly acyclovir. PMID:27342782

  11. Role of ascitic fluid adenosine deaminase (ADA) and serum CA-125 in the diagnosis of tuberculous peritonitis.

    PubMed

    Ali, N; Nath, N C; Parvin, R; Rahman, A; Bhuiyan, T M; Rahman, M; Mohsin M N

    2014-12-01

    This cross sectional study was carried out in the department of gastroenterology, BIRDEM, Dhaka from January 2010 to May 2011 to determine the role of ascitic fluid ADA and serum CA-125 in the diagnosis of clinically suspected tubercular peritonitis. Total 30 patients (age 39.69 ± 21.26, 18M/12F) with clinical suspicion of tuberculosis peritonitis were included in this study after analyzing selection criteria. Laparoscopic peritoneal biopsy with 'histopathological diagnosis' was considered gold standard against which accuracics of two biomarkers (ADA & CA-125) were compared. Cut off value of ADA and CA-125 are 24 u/l, 35 U/ml respectively. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy of ADA as a diagnostic modality in tuberculos peritonitis were 87.5%, 83.33%, 95.45%, 62.5% and 86.67% respectively where as CA-125 was found to have 83.33% sensitivity, 50% specificity, 86.9% positive predictive value, 42.85% negative predictive value and 76.6% accuracy. Both biomarkers are simple, non-invasive, rapid and relatively cheap diagnostic test where as laparoscopy is an invasive procedure, costly & requires trained staff and not without risk and also not feasible in all the centre in our country. So ascitic fluid ADA and serum CA-125 are important diagnostic test for peritoneal tuberculosis.

  12. Bronchoscopic Diagnosis of Langerhans Cell Histiocytosis and Lymphangioleiomyomatosis

    PubMed Central

    Harari, Sergio; Torre, Olga; Cassandro, Roberto; Taveira-DaSilva, Angelo M.; Moss, Joel

    2012-01-01

    Limited data are available regarding the role of bronchoalveolar lavage (BAL) and transbronchial lung biopsy (TBB) as diagnostic tools in pulmonary Langerhans’ Cell Histiocytosis (LCH) and lymphangioleiomyomatosis (LAM). The aim of this study was to review our experience regarding the value of these two techniques in the diagnosis of these cystic lung diseases. Records of 452 patients with the presumptive diagnosis of interstitial lung disease were reviewed; 67 had a clinical-radiological diagnosis of either LCH (n=27) or LAM (n= 40). Of 16 patients with LCH who underwent BAL, four specimens (25%) contained cells which had positive immunoreactivity for CD1a. Of three patients with negative BAL fluid who had TBB, only one had a positive tissue diagnosis. Ten LCH patients were diagnosed by surgical lung biopsy of which five had negative BAL fluid. The remaining 12 patients were diagnosed by clinical and radiologic features. Standard examination of BAL fluid was of no diagnostic value in LAM. TBB was performed in seven patients and was diagnostic in six, not resulting in complications. All 13 patients who underwent surgical lung biopsies had a positive histopathologic diagnosis The remaining 21 patients were diagnosed by clinical and radiologic features. We suggest that BAL may assist in the diagnosis of LCH whereas TBB may be useful in the diagnosis of LAM, thus avoiding the need for surgical biopsy. PMID:22770823

  13. A Simple Method for Differentiating Complicated Parapneumonic Effusion/Empyema from Parapneumonic Effusion Using the Split Pleura Sign and the Amount of Pleural Effusion on Thoracic CT.

    PubMed

    Tsujimoto, Naoki; Saraya, Takeshi; Light, Richard W; Tsukahara, Yayoi; Koide, Takashi; Kurai, Daisuke; Ishii, Haruyuki; Kimura, Hirokazu; Goto, Hajime; Takizawa, Hajime

    2015-01-01

    Pleural separation, the "split pleura" sign, has been reported in patients with empyema. However, the diagnostic yield of the split pleura sign for complicated parapneumonic effusion (CPPE)/empyema and its utility for differentiating CPPE/empyema from parapneumonic effusion (PPE) remains unclear. This differentiation is important because CPPE/empyema patients need thoracic drainage. In this regard, the aim of this study was to develop a simple method to distinguish CPPE/empyema from PPE using computed tomography (CT) focusing on the split pleura sign, fluid attenuation values (HU: Hounsfield units), and amount of fluid collection measured on thoracic CT prior to diagnostic thoracentesis. A total of 83 consecutive patients who underwent chest CT and were diagnosed with CPPE (n=18)/empyema (n=18) or PPE (n=47) based on the diagnostic thoracentesis were retrospectively analyzed. On univariate analysis, the split pleura sign (odds ratio (OR), 12.1; p<0.001), total amount of pleural effusion (≥30 mm) (OR, 6.13; p<0.001), HU value≥10 (OR, 5.94; p=0.001), and the presence of septum (OR, 6.43; p=0.018), atelectasis (OR, 6.83; p=0.002), or air (OR, 9.90; p=0.002) in pleural fluid were significantly higher in the CPPE/empyema group than in the PPE group. On multivariate analysis, only the split pleura sign (hazard ratio (HR), 6.70; 95% confidence interval (CI), 1.91-23.5; p=0.003) and total amount of pleural effusion (≥30 mm) on thoracic CT (HR, 7.48; 95%CI, 1.76-31.8; p=0.006) were risk factors for empyema. Sensitivity, specificity, positive predictive value, and negative predictive value of the presence of both split pleura sign and total amount of pleural effusion (≥30 mm) on thoracic CT for CPPE/empyema were 79.4%, 80.9%, 75%, and 84.4%, respectively, with an area under the curve of 0.801 on receiver operating characteristic curve analysis. This study showed a high diagnostic yield of the split pleura sign and total amount of pleural fluid (≥30 mm) on thoracic CT that is useful and simple for discriminating between CPPE/empyema and PPE prior to diagnostic thoracentesis.

  14. A Simple Method for Differentiating Complicated Parapneumonic Effusion/Empyema from Parapneumonic Effusion Using the Split Pleura Sign and the Amount of Pleural Effusion on Thoracic CT

    PubMed Central

    Tsujimoto, Naoki; Saraya, Takeshi; Light, Richard W.; Tsukahara, Yayoi; Koide, Takashi; Kurai, Daisuke; Ishii, Haruyuki; Kimura, Hirokazu; Goto, Hajime; Takizawa, Hajime

    2015-01-01

    Background Pleural separation, the “split pleura” sign, has been reported in patients with empyema. However, the diagnostic yield of the split pleura sign for complicated parapneumonic effusion (CPPE)/empyema and its utility for differentiating CPPE/empyema from parapneumonic effusion (PPE) remains unclear. This differentiation is important because CPPE/empyema patients need thoracic drainage. In this regard, the aim of this study was to develop a simple method to distinguish CPPE/empyema from PPE using computed tomography (CT) focusing on the split pleura sign, fluid attenuation values (HU: Hounsfield units), and amount of fluid collection measured on thoracic CT prior to diagnostic thoracentesis. Methods A total of 83 consecutive patients who underwent chest CT and were diagnosed with CPPE (n=18)/empyema (n=18) or PPE (n=47) based on the diagnostic thoracentesis were retrospectively analyzed. Results On univariate analysis, the split pleura sign (odds ratio (OR), 12.1; p<0.001), total amount of pleural effusion (≥30 mm) (OR, 6.13; p<0.001), HU value≥10 (OR, 5.94; p=0.001), and the presence of septum (OR, 6.43; p=0.018), atelectasis (OR, 6.83; p=0.002), or air (OR, 9.90; p=0.002) in pleural fluid were significantly higher in the CPPE/empyema group than in the PPE group. On multivariate analysis, only the split pleura sign (hazard ratio (HR), 6.70; 95% confidence interval (CI), 1.91-23.5; p=0.003) and total amount of pleural effusion (≥30 mm) on thoracic CT (HR, 7.48; 95%CI, 1.76-31.8; p=0.006) were risk factors for empyema. Sensitivity, specificity, positive predictive value, and negative predictive value of the presence of both split pleura sign and total amount of pleural effusion (≥30 mm) on thoracic CT for CPPE/empyema were 79.4%, 80.9%, 75%, and 84.4%, respectively, with an area under the curve of 0.801 on receiver operating characteristic curve analysis. Conclusion This study showed a high diagnostic yield of the split pleura sign and total amount of pleural fluid (≥30 mm) on thoracic CT that is useful and simple for discriminating between CPPE/empyema and PPE prior to diagnostic thoracentesis. PMID:26076488

  15. The recomBead Borrelia antibody index, CXCL13 and total IgM index for laboratory diagnosis of Lyme neuroborreliosis in children.

    PubMed

    Skogman, B H; Lager, M; Henningsson, A J; Tjernberg, I

    2017-11-01

    For laboratory diagnostics of Lyme neuroborreliosis (LNB), the recomBead Borrelia antibody index (AI) assay has shown promising results in a mixed age population, but has not previously been evaluated with specific focus on paediatric patients. The aim of the study was to evaluate the recomBead Borrelia AI assay in cerebrospinal fluid (CSF) for the laboratory diagnosis of LNB in children. We also wanted to explore whether early markers, such as CXCL13 in CSF and/or total IgM index could be useful as complementary diagnostic tools. Children being evaluated for LNB in a Swedish Lyme endemic area were included in the study (n = 146). Serum and CSF were collected on admission. Patients with other specific diagnoses were controls (n = 15). The recomBead Borrelia AI assay and the recomBead CXCL13 assay (Mikrogen) were applied together with total IgM index. The overall sensitivity for recomBead Borrelia AI (IgM and IgG together) was 74% and the specificity was 97%. However, the highest sensitivity (91%) at an acceptable level of specificity (90%) was obtained by recomBead Borrelia AI together with CXCL13 and total IgM index, showing a positive predictive value of 84% and a negative predictive value of 95%. Thus, the recomBead Borrelia AI assay performs with moderate sensitivity and high specificity in paediatric LNB patients. The major advantage seems to be increased sensitivity in the possible LNB group compared to the IDEIA assay. The diagnostic sensitivity may be further increased by using a combination of early markers, such as CXCL13 in CSF and total IgM index.

  16. Pathways from Birth Weight to ADHD Symptoms through Fluid Reasoning in Youth with or without Intellectual Disability.

    PubMed

    Morgan, Julia E; Lee, Steve S; Loo, Sandra K; Yuhan, Joshua W; Baker, Bruce L

    2018-05-01

    Although individual differences in fluid reasoning reliably mediate predictions of attention-deficit/hyperactivity disorder (ADHD) symptoms from birth weight in youth with typical cognitive development (TD), it is unknown if this indirect effect operates similarly in the development of ADHD symptoms secondary to intellectual disability (ID). Thus, we evaluated mediation by fluid reasoning in a longitudinal sample of 163 youth (45% female) with (n = 52) or without (n = 111) ID who were followed prospectively from age 5 to age 13. At age 9, youth completed the Arithmetic subtest of the Wechsler Intelligence Scale for Children, a measure of fluid reasoning. At ages 9 and 13, mothers and teachers separately rated youth ADHD symptoms and mothers completed a diagnostic interview. Mediation was tested via path analysis with bootstrapped confidence intervals, and moderated mediation estimated whether indirect effects differed between ID and TD youth or based on youth IQ. Controlling for demographic factors and age 9 ADHD symptoms, age 9 Arithmetic mediated birth weight and multi-method/informant age 13 ADHD symptoms, such that birth weight positively predicted Arithmetic, which negatively predicted ADHD symptoms. Neither ID status nor IQ moderated the observed indirect effect through Arithmetic, suggesting that it was similar for ID and TD youth as well as across the range of youth IQs. These findings support previous evidence that fluid reasoning, as measured by Arithmetic, may causally mediate birth weight and ADHD symptoms, and suggest that this pathway operates similarly with respect to the development of ADHD symptoms in youth with ID.

  17. Interleukin-6 in cerebrospinal fluid as a biomarker of acute meningitis.

    PubMed

    García-Hernández, Pablo; Prieto, Belén; Martínez-Morillo, Eduardo; Rodríguez, Verónica; Álvarez, Francisco V

    2016-01-01

    Microbiological culture of cerebrospinal fluid is the gold standard to differentiate between aseptic and bacterial meningitis, but this method has low sensitivity. A fast and reliable new marker would be of interest in clinical practice. Interleukin-6, secreted by T cells in response to meningeal pathogens and quickly delivered into cerebrospinal fluid, was evaluated as a marker of acute meningitis. A total of 150 cerebrospinal fluid samples were analysed by an electrochemiluminescence method, selected according to patient diagnosis: (a) bacterial meningitis confirmed by positive culture (n = 26); (b) bacterial meningitis with negative culture or not performed (n = 15); (c) viral meningitis confirmed by polymerase chain reaction or immunoglobulin G determination (n = 23); (d) viral meningitis with polymerase chain reaction negative or not performed (n = 42); and (e) controls (n = 44). Cerebrospinal fluid interleukin-6 concentration showed significant differences between all pathologic groups and the control group (P < 0.001). As a diagnostic tool for bacterial meningitis, interleukin-6 showed an area under the curve of 0.937 (95% confidence intervals: 0.895-0.978), significantly higher than those of classical biomarkers. An interleukin-6 cutoff of 1418 pg/mL showed 95.5% sensitivity and 77.5% specificity, whereas a value of 15,060 pg/mL showed 63.6% sensitivity and 96.7% specificity, for diagnosis of bacterial meningitis. Interleukin-6 measured by electrochemiluminescence method is a promising marker for early differentiation between aseptic and bacterial meningitis. More studies are needed to validate clinical implications for future practice in an emergency laboratory. © The Author(s) 2015.

  18. No added diagnostic value of non-phosphorylated tau fraction (p-taurel) in CSF as a biomarker for differential dementia diagnosis.

    PubMed

    Goossens, Joery; Bjerke, Maria; Struyfs, Hanne; Niemantsverdriet, Ellis; Somers, Charisse; Van den Bossche, Tobi; Van Mossevelde, Sara; De Vil, Bart; Sieben, Anne; Martin, Jean-Jacques; Cras, Patrick; Goeman, Johan; De Deyn, Peter Paul; Van Broeckhoven, Christine; van der Zee, Julie; Engelborghs, Sebastiaan

    2017-07-14

    The Alzheimer's disease (AD) cerebrospinal fluid (CSF) biomarkers Aβ 1-42 , t-tau, and p-tau 181 overlap with other diseases. New tau modifications or epitopes, such as the non-phosphorylated tau fraction (p-tau rel ), may improve differential dementia diagnosis. The goal of this study is to investigate if p-tau rel can improve the diagnostic performance of the AD CSF biomarker panel for differential dementia diagnosis. The study population consisted of 45 AD, 45 frontotemporal lobar degeneration (FTLD), 45 dementia with Lewy bodies (DLB), and 21 Creutzfeldt-Jakob disease (CJD) patients, and 20 cognitively healthy controls. A substantial subset of the patients was pathology-confirmed. CSF levels of Aβ 1-42 , t-tau, p-tau 181 , and p-tau rel were determined with commercially available single-analyte enzyme-linked immunosorbent assay (ELISA) kits. Diagnostic performance was evaluated by receiver operating characteristic (ROC) curve analyses, and area under the curve (AUC) values were compared using DeLong tests. The diagnostic performance of single markers as well as biomarker ratios was determined for each pairwise comparison of different dementia groups and controls. The addition of p-tau rel to the AD biomarker panel decreased its diagnostic performance when discriminating non-AD, FTLD, and DLB from AD. As a single marker, p-tau rel increased the diagnostic performance for CJD. No significant difference was found in AUC values with the addition of p-tau rel when differentiating between AD or non-AD dementias and controls. The addition of p-tau rel to the AD CSF biomarker panel failed to improve differentiation between AD and non-AD dementias.

  19. Usefulness of Two Aspergillus PCR Assays and Aspergillus Galactomannan and β-d-Glucan Testing of Bronchoalveolar Lavage Fluid for Diagnosis of Chronic Pulmonary Aspergillosis

    PubMed Central

    Urabe, Naohisa; Sano, Go; Suzuki, Junko; Hebisawa, Akira; Nakamura, Yasuhiko; Koyama, Kazuya; Ishii, Yoshikazu; Tateda, Kazuhiro; Homma, Sakae

    2017-01-01

    ABSTRACT We evaluated the usefulness of an Aspergillus galactomannan (GM) test, a β-d-glucan (βDG) test, and two different Aspergillus PCR assays of bronchoalveolar lavage fluid (BALF) samples for the diagnosis of chronic pulmonary aspergillosis (CPA). BALF samples from 30 patients with and 120 patients without CPA were collected. We calculated the sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio for each test individually and in combination with other tests. The optical density index values, as determined by receiver operating characteristic analysis, for the diagnosis of CPA were 0.5 and 100 for GM and βDG testing of BALF, respectively. The sensitivity and specificity of the GM test, βDG test, and PCR assays 1 and 2 were 77.8% and 90.0%, 77.8% and 72.5%, 86.7% and 84.2%, and 66.7% and 94.2%, respectively. A comparison of the PCR assays showed that PCR assay 1 had a better sensitivity, a better negative predictive value, and a better negative likelihood ratio and PCR assay 2 had a better specificity, a better positive predictive value, and a better positive likelihood ratio. The combination of the GM and βDG tests had the highest diagnostic odds ratio. The combination of the GM and βDG tests on BALF was more useful than any single test for diagnosing CPA. PMID:28330887

  20. The new agreement of the international RIGA consensus conference on nasal airway function tests.

    PubMed

    Vogt, K; Bachmann-Harildstad, G; Lintermann, A; Nechyporenko, A; Peters, F; Wernecke, K D

    2018-01-21

    The report reflects an agreement based on the consensus conference of the International Standardization Committee on the Objective Assessment of the Nasal Airway in Riga, 2nd Nov. 2016. The aim of the conference was to address the existing nasal airway function tests and to take into account physical, mathematical and technical correctness as a base of international standardization as well as the requirements of the Council Directive 93/42/EEC of 14 June 1993 concerning medical devices. Rhinomanometry, acoustic rhinometry, peak nasal inspiratory flow, Odiosoft-Rhino, optical rhinometry, 24-h measurements, computational fluid dynamics, nasometry and the mirrow test were evaluated for important diagnostic criteria, which are the precision of the equipment including calibration and the software applied; validity with sensitivity, specificity, positive and negative predictive values, reliability with intra-individual and inter-individual reproducibility and responsiveness in clinical studies. For rhinomanometry, the logarithmic effective resistance was set as the parameter of high diagnostic relevance. In acoustic rhinometry, the area of interest for the minimal cross-sectional area will need further standardization. Peak nasal inspiratory flow is a reproducible and fast test, which showed a high range of mean values in different studies. The state of the art with computational fluid dynamics for the simulation of the airway still depends on high performance computing hardware and will, after standardization of the software and both the software and hardware for imaging protocols, certainly deliver a better understanding of the nasal airway flux.

  1. Hydropneumothorax Due to Esophageal Rupture.

    PubMed

    Shiber, Joseph R; Fontane, Emily; Ra, Jin H; Kerwin, Andrew J

    2017-06-01

    A brief review of the historical aspects of esophageal rupture is presented along with a case and current recommendations for diagnostic evaluation and treatment. A 97-year-old woman complained of acute dyspnea without prior vomiting. Chest x-ray study showed a large right pneumothorax with associated effusion. A thoracostomy tube was placed with return of > 1 L turbid fluid with polymicrobial culture and elevated pleural fluid amylase level. Chest computed tomography (CT) scan demonstrated overt leakage of oral contrast into the right pleural space. She was treated with ongoing pleural evacuation, antibiotics, antifungals, and total parenteral nutrition. The patient and family declined surgical resection as well as endoscopic stent placement. In 1724, Boerhaave described spontaneous rupture of the esophagus postmortem; Boerhaave syndrome remains the name for complete disruption of the esophageal wall in the absence of pre-existing pathology typically occurring after vomiting. It most commonly occurs in the distal left posterolateral thoracic esophagus. Contrast esophagram is considered the "gold standard" for diagnosing esophageal rupture although CT esophagography also shows good diagnostic performance. Treatment includes nil per os status, broad-spectrum antibiotics, and drainage of the pleural space. Surgical repair of the esophageal perforation should be done early if the patient is deemed a good candidate, and esophageal stenting is also an option. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: Esophageal perforation should be suspected in patients with new pleural effusion, often with overt pneumothorax, that is polymicrobial with elevated amylase. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Diagnostic value of (1 → 3)-β-D-glucan in bronchoalveolar lavage fluid for invasive fungal disease: A meta-analysis.

    PubMed

    Shi, Xin-Yu; Liu, Yao; Gu, Xian-Min; Hao, Sheng-Yu; Wang, Yu-Hong; Yan, Di; Jiang, Shu-Juang

    2016-08-01

    The serum (1 → 3)-β-D-glucan (BG) assay has been approved for diagnosing invasive fungal diseases (IFDs). However, the performance of (1 → 3)-β-D-glucan assay in bronchoalveolar lavage (BAL) fluid is various among studies. The present study aimed to assess the accuracy of (1 → 3)-β-D-glucan assay in bronchoalveolar lavage fluid for the diagnosis of invasive fungal diseases by means of meta-analysis and systematic review of relevant studies. The sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (OR) and a summary receiver-operating characteristic curve of BAL-BG for diagnosing invasive fungal diseases were pooled using meta-analysis. We also performed meta-regression analysis. A total of 838 patients (138 with proven or probable invasive fungal diseases), included in 6 studies, were analyzed. The pooled sensitivity, specificity, PLR, NLR and diagnostic odds ratio were 0.52 (95%CI, 0.38-0.53), 0.58 (95%CI, 0.55-0.61), 1.34 (95%CI, 1.08-1.66), 0.82 (95% CI, 0.63-1.07) and 1.71 (95%CI, 1.01-2.92) respectively. The area under the summary receiver operating characteristic curve, with 95% confidence intervals was 0.61 (95%CI, 0.67-0.55). The accuracy of (1 → 3)-β-D-glucan test in bronchoalveolar lavage fluid is marginal, so that the results should not be interpreted alone but can be used as a part of full assessment with clinical features, image findings and other laboratory results for the diagnosis of invasive fungal diseases. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Detection of African Swine Fever Virus Antibodies in Serum and Oral Fluid Specimens Using a Recombinant Protein 30 (p30) Dual Matrix Indirect ELISA.

    PubMed

    Giménez-Lirola, Luis G; Mur, Lina; Rivera, Belen; Mogler, Mark; Sun, Yaxuan; Lizano, Sergio; Goodell, Christa; Harris, D L Hank; Rowland, Raymond R R; Gallardo, Carmina; Sánchez-Vizcaíno, José Manuel; Zimmerman, Jeff

    2016-01-01

    In the absence of effective vaccine(s), control of African swine fever caused by African swine fever virus (ASFV) must be based on early, efficient, cost-effective detection and strict control and elimination strategies. For this purpose, we developed an indirect ELISA capable of detecting ASFV antibodies in either serum or oral fluid specimens. The recombinant protein used in the ELISA was selected by comparing the early serum antibody response of ASFV-infected pigs (NHV-p68 isolate) to three major recombinant polypeptides (p30, p54, p72) using a multiplex fluorescent microbead-based immunoassay (FMIA). Non-hazardous (non-infectious) antibody-positive serum for use as plate positive controls and for the calculation of sample-to-positive (S:P) ratios was produced by inoculating pigs with a replicon particle (RP) vaccine expressing the ASFV p30 gene. The optimized ELISA detected anti-p30 antibodies in serum and/or oral fluid samples from pigs inoculated with ASFV under experimental conditions beginning 8 to 12 days post inoculation. Tests on serum (n = 200) and oral fluid (n = 200) field samples from an ASFV-free population demonstrated that the assay was highly diagnostically specific. The convenience and diagnostic utility of oral fluid sampling combined with the flexibility to test either serum or oral fluid on the same platform suggests that this assay will be highly useful under the conditions for which OIE recommends ASFV antibody surveillance, i.e., in ASFV-endemic areas and for the detection of infections with ASFV isolates of low virulence.

  4. Performance evaluation of the new hematology analyzer Sysmex XN-series.

    PubMed

    Seo, J Y; Lee, S-T; Kim, S-H

    2015-04-01

    The Sysmex XN-series is a new automated hematology analyzer designed to improve the accuracy of cell counts and the specificity of the flagging events. The basic characteristics and the performance of new measurement channels of the XN were evaluated and compared with the Sysmex XE-2100 and the manual method. Fluorescent platelet count (PLT-F) was compared with the flow cytometric method. The low WBC mode and body fluid mode were also evaluated. For workflow analysis, 1005 samples were analyzed on both the XN and the XE-2100, and manual review rates were compared. All parameters measured by the XN correlated well with the XE-2100. PLT-F showed better correlation with the flow cytometric method (r(2)  = 0.80) compared with optical platelet count (r(2)  = 0.73) for platelet counts <70 × 10(9) /L. The low WBC mode reported accurate leukocyte differentials for samples with a WBC count <0.5 × 10(9) /L. Relatively good correlation was found for WBC counts between the manual method and the body fluid mode (r = 0.88). The XN made less flags than the XE-2100, while the sensitivities of both instruments were comparable. The XN provided reliable results on low cell counts, as well as reduced manual blood film reviews, while maintaining a proper level of diagnostic sensitivity. © 2014 John Wiley & Sons Ltd.

  5. CT and MR findings in synovial chondromatosis of the temporo-mandibular joint: our experience and review of literature.

    PubMed

    Testaverde, Lorenzo; Perrone, Anna; Caporali, Laura; Ermini, Antonella; Izzo, Luciano; D'Angeli, Ilaria; Impara, Luca; Mazza, Dario; Izzo, Paolo; Marini, Mario

    2011-06-01

    To compare Computed Tomography (CT) and Magnetic Resonance (MR) features and their diagnostic potential in the assessment of Synovial Chondromatosis (SC) of the Temporo-Mandibular Joint (TMJ). Eight patients with symptoms and signs compatible with dysfunctional disorders of the TMJ underwent CT and MR scan. We considered the following parameters: soft tissue involvement (disk included), osteostructural alterations of the joints, loose bodies and intra-articular fluid. These parameters were evaluated separately by two radiologists with a "double blinded method" and then, after agreement, definitive assessment of the parameters was given. CT and MR findings were compared. Histopathological results showed metaplastic synovia in all patients and therefore confirmed diagnosis of SC. MR resulted better than CT in the evaluation of all parameters except the osteostructural alterations of the joints, estimated with more accuracy by CT scan. CT scan is excellent to define bony surfaces of the articular joints and flogistic tissue but it fails in the detection of loose bodies when these are not yet calcified. MR scan therefore is the gold standard when SC is suspected since it can visualize loose bodies at early stage and also evaluate disk condition and eventual extra-articular tissues involvement. The use of T2-weighted images and contrast medium allows identifying intra-articular fluid, estimating its entity and discriminating from sinovial tissue. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  6. Accuracy of vaginal symptom self-diagnosis algorithms for deployed military women.

    PubMed

    Ryan-Wenger, Nancy A; Neal, Jeremy L; Jones, Ashley S; Lowe, Nancy K

    2010-01-01

    Deployed military women have an increased risk for development of vaginitis due to extreme temperatures, primitive sanitation, hygiene and laundry facilities, and unavailable or unacceptable healthcare resources. The Women in the Military Self-Diagnosis (WMSD) and treatment kit was developed as a field-expedient solution to this problem. The primary study aims were to evaluate the accuracy of women's self-diagnosis of vaginal symptoms and eight diagnostic algorithms and to predict potential self-medication omission and commission error rates. Participants included 546 active duty, deployable Army (43.3%) and Navy (53.6%) women with vaginal symptoms who sought healthcare at troop medical clinics on base.In the clinic lavatory, women conducted a self-diagnosis using a sterile cotton swab to obtain vaginal fluid, a FemExam card to measure positive or negative pH and amines, and the investigator-developed WMSD Decision-Making Guide. Potential self-diagnoses were "bacterial infection" (bacterial vaginosis [BV] and/or trichomonas vaginitis [TV]), "yeast infection" (candida vaginitis [CV]), "no infection/normal," or "unclear." The Affirm VPIII laboratory reference standard was used to detect clinically significant amounts of vaginal fluid DNA for organisms associated with BV, TV, and CV. Women's self-diagnostic accuracy was 56% for BV/TV and 69.2% for CV. False-positives would have led to a self-medication commission error rate of 20.3% for BV/TV and 8% for CV. Potential self-medication omission error rates due to false-negatives were 23.7% for BV/TV and 24.8% for CV. The positive predictive value of diagnostic algorithms ranged from 0% to 78.1% for BV/TV and 41.7% for CV. The algorithms were based on clinical diagnostic standards. The nonspecific nature of vaginal symptoms, mixed infections, and a faulty device intended to measure vaginal pH and amines explain why none of the algorithms reached the goal of 95% accuracy. The next prototype of the WMSD kit will not include nonspecific vaginal signs and symptoms in favor of recently available point-of-care devices that identify antigens or enzymes of the causative BV, TV, and CV organisms.

  7. The use of semi-quantitative tests at Cesarean section delivery for the differentiation of canine fetal fluids from maternal urine on the basis of biochemical characteristics.

    PubMed

    Balogh, Orsolya; Roch, Marie; Keller, Stefanie; Michel, Erika; Reichler, Iris M

    2017-01-15

    In dogs, there is no diagnostic test to identify and differentiate fetal fluids from maternal urine in the event that a clear-yellowish vulvar discharge is observed pre-whelping. The objective of this study was to find a test that could easily and accurately identify rupture of the fetal membranes preceding parturition. Maternal urine, and amniotic fluid (AMF) and allantoic fluid (ALF) from only one fetus per bitch, were collected intraoperatively during Cesarean section. Specific gravity (SG) was analyzed with a refractometer, whereas the presence of leukocytes, protein, glucose, ketones, bilirubin, urobilinogen, nitrite, erythrocyte/hemoglobin (Hb), and the pH were assessed using a urine dipstick (Combur-Test ® ). Combined calcium and magnesium (Ca/Mg) content were evaluated with the Total Hardness Test. The AmniSure test, which detects rupture of fetal membranes in women on the basis of the presence of human placental alpha microglobulin-1, was also performed on canine AMF, ALF, and urine. Data were analyzed using the Fisher's exact test, Wilcoxon signed-rank test, and Pearson's correlation. Sensitivity, specificity, and positive and negative likelihood ratios (LR) were calculated for parameters with significant difference between urine and both fetal fluids. Maternal urine had higher SG and lower leukocyte, protein, Hb, and Ca/Mg content than AMF and ALF. Glucose was more often present in AMF (n = 17) and ALF (n = 12) than in urine (n = 1), whereas ketone bodies were rarely detected in ALF compared with urine. Bilirubin content was higher in urine and ALF than in AMF. AMF pH was less variable and higher than the pH of ALF or urine. The AmniSure was negative in all samples tested. Sensitivity and specificity for SG and for the detection of leukocytes, protein, glucose, Hb, Ca/Mg, and glucose without ketones in urine and fetal fluids were between 42% to 100% and 65% to 100%, respectively. Best positive LR was achieved for the detection of glucose without ketones and best negative LR for SG of 1.022 or less. In conclusion, the AmniSure test, which is used in humans with high diagnostic accuracy, cannot identify AMF and ALF in dogs. On the basis of our results in 26 dogs undergoing Cesarean section, the presence or absence of fetal fluids could be best determined by a positive glucose test without ketone bodies or by SG higher than 1.022, respectively. These tests may serve as additional tools to recognize parturition if clear-yellowish vulvar discharge is present in a term pregnant bitch, but their accuracy and practicability in the clinical setting need to be confirmed. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Significance of immune response to Mycobacterium tuberculosis culture filtrate protein antigens in cerebrospinal fluid of tuberculous meningitis patients: A search for diagnostic marker.

    PubMed

    Giribhattanavar, Prashant; Kumar, Kavitha; Raajasekar, Siddarth; Chandrashekar, Nagarathna; Patil, Shripad A

    2017-01-01

    Mycobacterium tuberculosis (H37Ra) culture filtrate proteins (CFP) are explored as a diagnostic marker for tuberculous meningitis (TBM). Cerebrospinal fluid (CSF) samples from patients were categorized as confirmed (n = 47), suspected (n = 20), and non-TBM (n = 25) cases. Immune response by Western blot revealed TBM CSF samples are having heterogeneous response to CFP. CFP ELISA was 92% sensitive and 38.30% specific. ODs of confirmed TBM and non-TBM cases were significantly different (P < 0.0001) and also the suspected TBM and non-TBM cases (P = 0.0001). No significant difference noticed in TBM and suspected TBM (P = 0.90). Thus, CFP can be a better biomarker for the diagnosis of TBM.

  9. Does more favourable handling of the cerebrospinal fluid increase the diagnostic sensitivity of Borrelia burgdorferi sensu lato-specific PCR in Lyme neuroborreliosis?

    PubMed

    Forselv, Kristine J N; Lorentzen, Åslaug R; Ljøstad, Unn; Mygland, Åse; Eikeland, Randi; Kjelland, Vivian; Noraas, Sølvi; Quarsten, Hanne

    2018-04-01

    Tests for direct detection of Borrelia burgdorferi sensu lato (Bb) in Lyme neuroborreliosis (LNB) are needed. Detection of Bb DNA using PCR is promising, but clinical utility is hampered by low diagnostic sensitivity. We aimed to examine whether diagnostic sensitivity can be improved by the use of larger cerebrospinal fluid (CSF) volumes and faster handling of samples. Patients who underwent CSF examination for LNB were included. We collected two millilitres of CSF for PCR analysis, extracted DNA from the pellets within 24 h and analysed the eluate by two real-time PCR protocols (16S rRNA and OspA). Patients who fulfilled diagnostic criteria for LNB were classified as LNB cases and the rest as controls. Bb DNA in CSF was detected by PCR in seven of 28 adults with LNB. Two were Bb antibody negative. No Bb DNA was detected in CSF from 137 controls. Diagnostic sensitivity was 25% and specificity 100%. There was a non-significant trend towards larger CSF sample volume, faster handling of the sample, shorter duration of symptoms, and higher CSF cell count in the PCR-positive cases. We did not find that optimized handling of CSF increased diagnostic sensitivity of PCR in adults with LNB. However, our case series is small and we hypothesize that the importance of these factors will be clarified in further studies with larger case series and altered study design. PCR for diagnosis of LNB may be useful in cases without Bb antibodies due to short duration of symptoms.

  10. Postoperative Takotsubo cardiomyopathy triggered by intraoperative fluid overload and acute hypertensive crisis.

    PubMed

    Varutti, Rosanna; Setti, Tommaso; Ezri, Tiberiu; Nicolosi, Gianluigi; Rellini, Gianluigi; Cassin, Matteo; Leykin, Yigal

    2015-04-01

    The Takotsubo cardiomyopathy is a rare haemodynamic dysfunction, only recently reported perioperatively. While the diagnostic criteria have been established and the outcome is known as favorable, the pathophysiological mechanisms are not entirely understood. Here we present the case of a patient scheduled for laparoscopic hysterectomy and adnexectomy, who early postoperatively developed a Takotsubo cardiomyopathy supposedly triggered by an acute hypertensive crisis due to intraoperative fluid overload.

  11. CK-MB Test

    MedlinePlus

    ... Free Fetal DNA Cerebrospinal Fluid (CSF) Analysis Ceruloplasmin Chemistry Panels Chickenpox and Shingles Tests Chlamydia Testing Chloride ... Missouri. Pp. 312-315. Tietz Textbook of Clinical Chemistry and Molecular Diagnostics. Burtis CA, Ashwood ER and ...

  12. Physics through the 1990s: Plasmas and fluids

    NASA Technical Reports Server (NTRS)

    1986-01-01

    The volume contains recommendations for programs in, and government support of, plasma and fluid physics. Four broad areas are covered: the physics of fluids, general plasma physics, fusion, and space and astrophysical plasmas. In the first section, the accomplishments of fluid physics and a detailed review of its sub-fields, such as combustion, non-Newtonian fluids, turbulence, aerodynamics, and geophysical fluid dynamics, are described. The general plasma physics section deals with the wide scope of the theoretical concepts involved in plasma research, and with the machines; intense beam systems, collective and laser-driven accelerators, and the associated diagnostics. The section on the fusion plasma research program examines confinement and heating systems, such as Tokamaks, magnetic mirrors, and inertial-confinement systems, and several others. Finally, theory and experiment in space and astrophysical plasma research is detailed, ranging from the laboratory to the solar system and beyond. A glossary is included.

  13. Added Diagnostic Value of Cerebrospinal Fluid Biomarkers for Differential Dementia Diagnosis in an Autopsy-Confirmed Cohort.

    PubMed

    Niemantsverdriet, Ellis; Feyen, Bart F E; Le Bastard, Nathalie; Martin, Jean-Jacques; Goeman, Johan; De Deyn, Peter Paul; Bjerke, Maria; Engelborghs, Sebastiaan

    2018-01-01

    Differential dementia diagnosis remains a challenge due to overlap of clinical profiles, which often results in diagnostic doubt. Determine the added diagnostic value of cerebrospinal fluid (CSF) biomarkers for differential dementia diagnosis as compared to autopsy-confirmed diagnosis. Seventy-one dementia patients with autopsy-confirmed diagnoses were included in this study. All neuropathological diagnoses were established according to standard neuropathological criteria and consisted of Alzheimer's disease (AD) or other dementias (NONAD). CSF levels of Aβ1 - 42, T-tau, and P-tau181 were determined and interpreted based on the IWG-2 and NIA-AA criteria, separately. A panel of three neurologists experienced with dementia made clinical consensus dementia diagnoses. Clinical and CSF biomarker diagnoses were compared to the autopsy-confirmed diagnoses. Forty-two patients (59%) had autopsy-confirmed AD, whereas 29 patients (41%) had autopsy-confirmed NONAD. Of the 24 patients with an ambiguous clinical dementia diagnosis, a correct diagnosis would have been established in 67% of the cases applying CSF biomarkers in the context of the IWG-2 or the NIA-AA criteria respectively. AD CSF biomarkers have an added diagnostic value in differential dementia diagnosis and can help establishing a correct dementia diagnosis in case of ambiguous clinical dementia diagnoses.

  14. Non-small cell lung cancer detection using microRNA expression profiling of bronchoalveolar lavage fluid and sputum.

    PubMed

    Kim, Julian O; Gazala, Sayf; Razzak, Rene; Guo, Linghong; Ghosh, Sunita; Roa, Wilson H; Bédard, Eric L R

    2015-04-01

    To assess if miRNA expression profiling of bronchoalveolar lavage (BAL) fluid and sputum could be used to detect early-stage non-small cell lung cancer (NSCLC). Hierarchical cluster analysis was performed on the expression levels of 5 miRNAs (miR-21, miR-143, miR-155, miR-210, and miR-372) which were quantified using RNA reverse transcription and quantitative real-time polymerase chain reaction in sputum and BAL samples from NSCLC cases and cancer-free controls. Cluster analysis of the miRNA expression levels in BAL samples from 21 NSCLC cases and sputum samples from 10 cancer-free controls yielded a diagnostic sensitivity of 85.7% and specificity of 100%. Cluster analysis of sputum samples from the same patients yielded a diagnostic sensitivity of 67.8% and specificity of 90%. miRNA expression profiling of sputum and BAL fluids represent a potential means to detect early-stage NSCLC. Copyright© 2015 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  15. Coupling apparatus for ultrasonic medical diagnostic system

    NASA Technical Reports Server (NTRS)

    Frazer, R. E. (Inventor)

    1978-01-01

    An apparatus for the ultrasonic scanning of a breast or other tissue is reported that contains a cavity for receiving the breast, a vacuum for drawing the breast into intimate contact with the walls of the cavity, and transducers coupled through a fluid to the cavity to transmit sound waves through the breast. Each transducer lies at the end of a tapered chamber which has flexible walls and which is filled with fluid, so that the transducer can be moved in a raster pattern while the chamber walls flex accordingly, with sound transmission always occurring through the fluid.

  16. Blood Urea Nitrogen Test

    MedlinePlus

    ... Free Fetal DNA Cerebrospinal Fluid (CSF) Analysis Ceruloplasmin Chemistry Panels Chickenpox and Shingles Tests Chlamydia Testing Chloride ... mmol/L 1 from Tietz Textbook of Clinical Chemistry and Molecular Diagnostics. Burtis CA, Ashwood ER, Bruns ...

  17. Seminal plasma as a diagnostic fluid for male reproductive system disorders.

    PubMed

    Drabovich, Andrei P; Saraon, Punit; Jarvi, Keith; Diamandis, Eleftherios P

    2014-05-01

    Molecular biomarkers hold promise to advance the noninvasive diagnosis of male reproductive system disorders and facilitate the identification and management of these conditions through screening, early diagnosis and more accurate prognosis. Seminal plasma has great potential as a proximal fluid for protein biomarker discovery and as a clinical sample for noninvasive diagnostics. The seminal plasma proteome contains thousands of proteins and includes a large number of tissue-specific proteins that might accurately indicate a pathological process in the tissue of origin. Potential protein biomarkers for male reproductive system disorders are more abundant in seminal plasma than in blood serum or urine, and, therefore, are more easily identified and quantified in semen by mass spectrometry and other techniques. These methods have enabled elaboration of the composition of the seminal plasma proteome and the tissue specificity of seminal plasma proteins. Strategies have been developed to discover protein biomarkers in seminal plasma through integrated 'omics' approaches. Biomarkers of male infertility and prostate cancer are now emerging, and it is evident that seminal plasma has the potential to complement other diagnostic tools available in urology clinics.

  18. Thermal Imaging of Convecting Opaque Fluids using Ultrasound

    NASA Technical Reports Server (NTRS)

    Xu, Hongzhou; Fife, Sean; Andereck, C. David

    2002-01-01

    An ultrasound technique has been developed to non-intrusively image temperature fields in small-scale systems of opaque fluids undergoing convection. Fluids such as molten metals, semiconductors, and polymers are central to many industrial processes, and are often found in situations where natural convection occurs, or where thermal gradients are otherwise important. However, typical thermal and velocimetric diagnostic techniques rely upon transparency of the fluid and container, or require the addition of seed particles, or require mounting probes inside the fluid, all of which either fail altogether in opaque fluids, or necessitate significant invasion of the flow and/or modification of the walls of the container to allow access to the fluid. The idea behind our work is to use the temperature dependence of sound velocity, and the ease of propagation of ultrasound through fluids and solids, to probe the thermal fields of convecting opaque fluids non-intrusively and without the use of seed particles. The technique involves the timing of the return echoes from ultrasound pulses, a variation on an approach used previously in large-scale systems.

  19. Fourier domain optical coherence tomographic and auto-fluorescence findings in indeterminate choroidal melanocytic lesions.

    PubMed

    Singh, Arun D; Belfort, Rubens N; Sayanagi, Kaori; Kaiser, Peter K

    2010-04-01

    To compare detection rates of drusen and subretinal fluid by Fourier domain optical coherence tomography (FD OCT) and orange pigment by fundus autofluorescence (FAF) with ophthalmoscopy in indeterminate choroidal melanocytic lesions. In a consecutive case series of 38 patients with indeterminate choroidal melanocytic lesion that would have been categorised as a small tumour according to the size-based nomenclature used in the Collaborative Ocular Melanoma Study, each eye was submitted to ophthalmoscopic examination, FD OCT and FAF. The presence of drusen, subretinal fluid and orange pigment was recorded for each lesion by a single observer at the time of initial ophthalmoscopic evaluation and on fundus photographs. FD OCT and autofluorescence images were reviewed in all cases in a masked fashion. The ophthalmoscopic examination revealed drusen in 42%, subretinal fluid in 53% and orange pigment in 50% of patients. FD-OCT detected drusen in 45% and subretinal fluid in 58% of cases, and FAF detected orange pigment in 58% of cases. Based on the McNemar test, none of the differences were statistically significant at the 0.05 level. FD OCT and FAF complement clinical examination by verifying and documenting retinal and RPE changes associated with indeterminate choroidal melanocytic lesions. The detection rates by FD OCT and FAF of important qualitative prognostic factors appear to be equivalent to ophthalmoscopy by a trained observer. Once validated in a larger number of patients, FD OCT and FAF findings can be incorporated into diagnostic algorithms.

  20. Large Scale Generation and Characterization of Anti-Human IgA Monoclonal Antibody in Ascitic Fluid of Balb/c Mice

    PubMed Central

    Ezzatifar, Fatemeh; Majidi, Jafar; Baradaran, Behzad; Aghebati Maleki, Leili; Abdolalizadeh, Jalal; Yousefi, Mehdi

    2015-01-01

    Purpose: Monoclonal antibodies are potentially powerful tools used in biomedical research, diagnosis, and treatment of infectious diseases and cancers. The monoclonal antibody against Human IgA can be used as a diagnostic application to detect infectious diseases. The aim of this study was to improve an appropriate protocol for large-scale production of mAbs against IgA. Methods: For large-scale production of the monoclonal antibody, hybridoma cells that produce monoclonal antibodies against Human IgA were injected intraperitoneally into Balb/c mice that were previously primed with 0.5 ml Pristane. After ten days, ascitic fluid was harvested from the peritoneum of each mouse. The ELISA method was carried out for evaluation of the titration of produced mAbs. The ascitic fluid was investigated in terms of class and subclass by a mouse mAb isotyping kit. MAb was purified from the ascitic fluid by ion exchange chromatography. The purity of the monoclonal antibody was confirmed by SDS-PAGE, and the purified monoclonal antibody was conjugated with HRP. Results: Monoclonal antibodies with high specificity and sensitivity against Human IgA were prepared by hybridoma technology. The subclass of antibody was IgG1 and its light chain was the kappa type. Conclusion: This conjugated monoclonal antibody could have applications in designing ELISA kits in order to diagnose different infectious diseases such as toxoplasmosis and H. Pylori. PMID:25789225

  1. Endosonography in the diagnosis and management of pancreatic cysts

    PubMed Central

    Kadiyala, Vivek; Lee, Linda S

    2015-01-01

    Rapid advances in radiologic technology and increased cross-sectional imaging have led to a sharp rise in incidental discoveries of pancreatic cystic lesions. These cystic lesions include non-neoplastic cysts with no risk of malignancy, neoplastic non-mucinous serous cystadenomas with little or no risk of malignancy, as well as neoplastic mucinous cysts and solid pseudopapillary neoplasms both with varying risk of malignancy. Accurate diagnosis is imperative as management is guided by symptoms and risk of malignancy. Endoscopic ultrasound (EUS) allows high resolution evaluation of cyst morphology and precise guidance for fine needle aspiration (FNA) of cyst fluid for cytological, chemical and molecular analysis. Initially, clinical evaluation and radiologic imaging, preferably with magnetic resonance imaging of the pancreas and magnetic resonance cholangiopancreatography, are performed. In asymptomatic patients where diagnosis is unclear and malignant risk is indeterminate, EUS-FNA should be used to confirm the presence or absence of high-risk features, differentiate mucinous from non-mucinous lesions, and diagnose malignancy. After analyzing the cyst fluid for viscosity, cyst fluid carcinoembryonic antigen, amylase, and cyst wall cytology should be obtained. DNA analysis may add useful information in diagnosing mucinous cysts when the previous studies are indeterminate. New molecular biomarkers are being investigated to improve diagnostic capabilities and management decisions in these challenging cystic lesions. Current guidelines recommend surgical pancreatic resection as the standard of care for symptomatic cysts and those with high-risk features associated with malignancy. EUS-guided cyst ablation is a promising minimally invasive, relatively low-risk alternative to both surgery and surveillance. PMID:25789091

  2. CXCL9 concentrations in cerebrospinal fluid and serum of patients with tick-borne encephalitis.

    PubMed

    Koper, Olga M; Kamińska, Joanna; Grygorczuk, Sambor; Zajkowska, Joanna; Kemona, Halina

    2018-03-01

    The aim of our current study was to evaluate cerebrospinal fluid (CSF) and serum CXCL9 concentrations and diagnostic usefulness of this molecule in tick-borne encephalitis (TBE). The study included TBE patients in the acute phase (TBE I) and after 2 weeks of follow-up (TBE II). The control group consisted of patients investigated for suspected central nervous system (CNS) infection, but with normal CSF findings. Concentrations of CXCL9 were measured using enzyme-linked immunosorbent assay (ELISA). Cerebrospinal fluid and serum concentrations of CXCL9 in patients with TBE were significantly higher than in controls ( p < 0.001). This alteration was also observed in the case of the CXCL9 index (I CXCL9 ; CSF CXCL9 concentration divided by serum CXCL9 concentration) ( p < 0.001); moreover, I CXCL9 significantly decreased after 2 weeks ( p < 0.001). This is the first study to evaluate the CSF and serum levels of CXCL9 in subjects with TBE. CXCL9 is a ligand for CXCR3, which was found on all Th1 memory lymphocytes present in the peripheral blood; therefore the elevated concentrations of CXCL9 in TBE patients as compared to the controls might indicate that this chemokine perhaps takes part in the trafficking of Th 1 cells into the CNS. The results presented here support the hypothesis that CXCL9 may play a role in TBE. However, further studies are required to determine whether this protein might be used as a potential tool for the diagnosis and monitoring of inflammation in TBE.

  3. Evaluation of cell count and classification capabilities in body fluids using a fully automated Sysmex XN equipped with high-sensitive Analysis (hsA) mode and DI-60 hematology analyzer system.

    PubMed

    Takemura, Hiroyuki; Ai, Tomohiko; Kimura, Konobu; Nagasaka, Kaori; Takahashi, Toshihiro; Tsuchiya, Koji; Yang, Haeun; Konishi, Aya; Uchihashi, Kinya; Horii, Takashi; Tabe, Yoko; Ohsaka, Akimichi

    2018-01-01

    The XN series automated hematology analyzer has been equipped with a body fluid (BF) mode to count and differentiate leukocytes in BF samples including cerebrospinal fluid (CSF). However, its diagnostic accuracy is not reliable for CSF samples with low cell concentration at the border between normal and pathologic level. To overcome this limitation, a new flow cytometry-based technology, termed "high sensitive analysis (hsA) mode," has been developed. In addition, the XN series analyzer has been equipped with the automated digital cell imaging analyzer DI-60 to classify cell morphology including normal leukocytes differential and abnormal malignant cells detection. Using various BF samples, we evaluated the performance of the XN-hsA mode and DI-60 compared to manual microscopic examination. The reproducibility of the XN-hsA mode showed good results in samples with low cell densities (coefficient of variation; % CV: 7.8% for 6 cells/μL). The linearity of the XN-hsA mode was established up to 938 cells/μL. The cell number obtained using the XN-hsA mode correlated highly with the corresponding microscopic examination. Good correlation was also observed between the DI-60 analyses and manual microscopic classification for all leukocyte types, except monocytes. In conclusion, the combined use of cell counting with the XN-hsA mode and automated morphological analyses using the DI-60 mode is potentially useful for the automated analysis of BF cells.

  4. Benefit-risk Evaluation for Diagnostics: A Framework (BED-FRAME).

    PubMed

    Evans, Scott R; Pennello, Gene; Pantoja-Galicia, Norberto; Jiang, Hongyu; Hujer, Andrea M; Hujer, Kristine M; Manca, Claudia; Hill, Carol; Jacobs, Michael R; Chen, Liang; Patel, Robin; Kreiswirth, Barry N; Bonomo, Robert A

    2016-09-15

    The medical community needs systematic and pragmatic approaches for evaluating the benefit-risk trade-offs of diagnostics that assist in medical decision making. Benefit-Risk Evaluation of Diagnostics: A Framework (BED-FRAME) is a strategy for pragmatic evaluation of diagnostics designed to supplement traditional approaches. BED-FRAME evaluates diagnostic yield and addresses 2 key issues: (1) that diagnostic yield depends on prevalence, and (2) that different diagnostic errors carry different clinical consequences. As such, evaluating and comparing diagnostics depends on prevalence and the relative importance of potential errors. BED-FRAME provides a tool for communicating the expected clinical impact of diagnostic application and the expected trade-offs of diagnostic alternatives. BED-FRAME is a useful fundamental supplement to the standard analysis of diagnostic studies that will aid in clinical decision making. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.

  5. Uncovering the molecular networks in periodontitis

    PubMed Central

    Trindade, Fábio; Oppenheim, Frank G.; Helmerhorst, Eva J.; Amado, Francisco; Gomes, Pedro S.; Vitorino, Rui

    2015-01-01

    Periodontitis is a complex immune-inflammatory disease that results from a preestablished infection in gingiva, mainly due to Gram-negative bacteria that colonize deeper in gingival sulcus and latter periodontal pocket. Host inflammatory and immune responses have both protective and destructive roles. Although cytokines, prostaglandins, and proteases struggle against microbial burden, these molecules promote connective tissue loss and alveolar bone resorption, leading to several histopathological changes, namely destruction of periodontal ligament, deepening of periodontal pocket, and bone loss, which can converge to attain tooth loss. Despite the efforts of genomics, transcriptomics, proteomics/peptidomics, and metabolomics, there is no available biomarker for periodontitis diagnosis, prognosis, and treatment evaluation, which could assist on the established clinical evaluation. Nevertheless, some genes, transcripts, proteins and metabolites have already shown a different expression in healthy subjects and in patients. Though, so far, ‘omics approaches only disclosed the host inflammatory response as a consequence of microbial invasion in periodontitis and the diagnosis in periodontitis still relies on clinical parameters, thus a molecular tool for assessing periodontitis lacks in current dental medicine paradigm. Saliva and gingival crevicular fluid have been attracting researchers due to their diagnostic potential, ease, and noninvasive nature of collection. Each one of these fluids has some advantages and disadvantages that are discussed in this review. PMID:24828325

  6. Can we better predict the biologic behavior of incidental IPMN? A comprehensive analysis of molecular diagnostics and biomarkers in intraductal papillary mucinous neoplasms of the pancreas.

    PubMed

    Tulla, Kiara A; Maker, Ajay V

    2018-03-01

    Predicting the biologic behavior of intraductal papillary mucinous neoplasm (IPMN) remains challenging. Current guidelines utilize patient symptoms and imaging characteristics to determine appropriate surgical candidates. However, the majority of resected cysts remain low-risk lesions, many of which may be feasible to have under surveillance. We herein characterize the most promising and up-to-date molecular diagnostics in order to identify optimal components of a molecular signature to distinguish levels of IPMN dysplasia. A comprehensive systematic review of pertinent literature, including our own experience, was conducted based on the PRISMA guidelines. Molecular diagnostics in IPMN patient tissue, duodenal secretions, cyst fluid, saliva, and serum were evaluated and organized into the following categories: oncogenes, tumor suppressor genes, glycoproteins, markers of the immune response, proteomics, DNA/RNA mutations, and next-generation sequencing/microRNA. Specific targets in each of these categories, and in aggregate, were identified by their ability to both characterize a cyst as an IPMN and determine the level of cyst dysplasia. Combining molecular signatures with clinical and imaging features in this era of next-generation sequencing and advanced computational analysis will enable enhanced sensitivity and specificity of current models to predict the biologic behavior of IPMN.

  7. The applied research of MRI with ASSET-EPI-FLAIR combined with 3D TOF MRA sequences in the assessment of patients with acute cerebral infarction.

    PubMed

    Lin, Zhichao; Guo, Zexiong; Qiu, Lin; Yang, Wanyoug; Lin, Mingxia

    2016-12-01

    Background To extend the time window for thrombolysis, reducing the time for diagnosis and detection of acute cerebral infarction seems to be warranted. Purpose To evaluate the feasibility of implementing an array spatial sensitivity technique (ASSET)-echo-planar imaging (EPI)-fluid attenuated inversion recovery (FLAIR) (AE-FLAIR) sequence into an acute cerebral infarction magnetic resonance (MR) evaluation protocol, and to assess the diagnostic value of AE-FLAIR combined with three-dimensional time-of-flight MR angiography (3D TOF MRA). Material and Methods A total of 100 patients (68 men, 32 women; age range, 44-82 years) with acute cerebral infarction, including 50 consecutive uncooperative and 50 cooperative patients, were evaluated with T1-weighted (T1W) imaging, T2-weighted (T2W) imaging, FLAIR, diffusion-weighted imaging (DWI), 3D TOF, EPI-FLAIR, and AE-FLAIR. Conventional FLAIR, EPI-FLAIR, and AE-FLAIR were assessed by two observers independently for image quality. The optimized group (AE-FLAIR and 3D TOF) and the control group (T1W imaging, T2W imaging, conventional FLAIR, DWI, and 3D TOF) were compared for evaluation time and diagnostic accuracy. Results One hundred and twenty-five lesions were detected and images having adequate diagnostic image quality were in 73% of conventional FLAIR, 62% of EPI-FLAIR, and 89% of AE-FLAIR. The detection time was 12 ± 1 min with 76% accuracy and 4 ± 0.5 min with 100% accuracy in the control and the optimized groups, respectively. Inter-observer agreements of κ = 0.78 and κ = 0.81 were for the optimized group and control group, respectively. Conclusion With reduced acquisition time and better image quality, AE-FLAIR combined with 3D TOF may be used as a rapid diagnosis tool in patients with acute cerebral infarction, especially in uncooperative patients.

  8. Radiographic and magnetic resonance imaging predicts severity of cruciate ligament fiber damage and synovitis in dogs with cranial cruciate ligament rupture

    PubMed Central

    Racette, Molly A.; Hans, Eric C.; Volstad, Nicola J.; Holzman, Gerianne; Bleedorn, Jason A.; Schaefer, Susan L.; Waller, Kenneth R.; Hao, Zhengling; Block, Walter F.

    2017-01-01

    Cruciate ligament rupture (CR) and associated osteoarthritis (OA) is a common condition in dogs. Dogs frequently develop a second contralateral CR. This study tested the hypothesis that the degree of stifle synovitis and cranial cruciate ligament (CrCL) matrix damage in dogs with CR is correlated with non-invasive diagnostic tests, including magnetic resonance (MR) imaging. We conducted a prospective cohort study of 29 client-owned dogs with an unstable stifle due to complete CR and stable contralateral stifle with partial CR. We evaluated correlation of stifle synovitis and CrCL fiber damage with diagnostic tests including bilateral stifle radiographs, 3.0 Tesla MR imaging, and bilateral stifle arthroscopy. Histologic grading and immunohistochemical staining for CD3+ T lymphocytes, TRAP+ activated macrophages and Factor VIII+ blood vessels in bilateral stifle synovial biopsies were also performed. Serum and synovial fluid concentrations of C-reactive protein (CRP) and carboxy-terminal telopeptide of type I collagen (ICTP), and synovial total nucleated cell count were determined. Synovitis was increased in complete CR stifles relative to partial CR stifles (P<0.0001), although total nucleated cell count in synovial fluid was increased in partial CR stifles (P<0.01). In partial CR stifles, we found that 3D Fast Spin Echo Cube CrCL signal intensity was correlated with histologic synovitis (SR = 0.50, P<0.01) and that radiographic OA was correlated with CrCL fiber damage assessed arthroscopically (SR = 0.61, P<0.001). Taken together, results of this study show that clinical diagnostic tests predict severity of stifle synovitis and cruciate ligament matrix damage in stable partial CR stifles. These data support use of client-owned dogs with unilateral complete CR and contralateral partial CR as a clinical trial model for investigation of disease-modifying therapy for partial CR. PMID:28575001

  9. Radiographic and magnetic resonance imaging predicts severity of cruciate ligament fiber damage and synovitis in dogs with cranial cruciate ligament rupture.

    PubMed

    Sample, Susannah J; Racette, Molly A; Hans, Eric C; Volstad, Nicola J; Holzman, Gerianne; Bleedorn, Jason A; Schaefer, Susan L; Waller, Kenneth R; Hao, Zhengling; Block, Walter F; Muir, Peter

    2017-01-01

    Cruciate ligament rupture (CR) and associated osteoarthritis (OA) is a common condition in dogs. Dogs frequently develop a second contralateral CR. This study tested the hypothesis that the degree of stifle synovitis and cranial cruciate ligament (CrCL) matrix damage in dogs with CR is correlated with non-invasive diagnostic tests, including magnetic resonance (MR) imaging. We conducted a prospective cohort study of 29 client-owned dogs with an unstable stifle due to complete CR and stable contralateral stifle with partial CR. We evaluated correlation of stifle synovitis and CrCL fiber damage with diagnostic tests including bilateral stifle radiographs, 3.0 Tesla MR imaging, and bilateral stifle arthroscopy. Histologic grading and immunohistochemical staining for CD3+ T lymphocytes, TRAP+ activated macrophages and Factor VIII+ blood vessels in bilateral stifle synovial biopsies were also performed. Serum and synovial fluid concentrations of C-reactive protein (CRP) and carboxy-terminal telopeptide of type I collagen (ICTP), and synovial total nucleated cell count were determined. Synovitis was increased in complete CR stifles relative to partial CR stifles (P<0.0001), although total nucleated cell count in synovial fluid was increased in partial CR stifles (P<0.01). In partial CR stifles, we found that 3D Fast Spin Echo Cube CrCL signal intensity was correlated with histologic synovitis (SR = 0.50, P<0.01) and that radiographic OA was correlated with CrCL fiber damage assessed arthroscopically (SR = 0.61, P<0.001). Taken together, results of this study show that clinical diagnostic tests predict severity of stifle synovitis and cruciate ligament matrix damage in stable partial CR stifles. These data support use of client-owned dogs with unilateral complete CR and contralateral partial CR as a clinical trial model for investigation of disease-modifying therapy for partial CR.

  10. [Premature fetal membrane rupture: report of a case of severe intrauterine fungal infection].

    PubMed

    Gauwerky, J; Schmidt, W; Kühn, H; Kubli, F

    1983-03-01

    A case of extremely rare intra-uterine candida infection is reported following premature rupture of the membranes. The diagnostic possibilities by transabdominal amniocentesis and determination of the causative organism in the amniotic fluid are presented. Even systemic antimykotic treatment is not capable of treating intra-uterine candidiasis sufficiently. This is proved among other parameters by the concentration of miconazol in the amniotic fluid and in the plasma of the newborn.

  11. Postoperative Takotsubo cardiomyopathy triggered by intraoperative fluid overload and acute hypertensive crisis

    PubMed Central

    Varutti, Rosanna; Setti, Tommaso; Ezri, Tiberiu; Nicolosi, Gianluigi; Rellini, Gianluigi; Cassin, Matteo; Leykin, Yigal

    2015-01-01

    The Takotsubo cardiomyopathy is a rare haemodynamic dysfunction, only recently reported perioperatively. While the diagnostic criteria have been established and the outcome is known as favorable, the pathophysiological mechanisms are not entirely understood. Here we present the case of a patient scheduled for laparoscopic hysterectomy and adnexectomy, who early postoperatively developed a Takotsubo cardiomyopathy supposedly triggered by an acute hypertensive crisis due to intraoperative fluid overload. PMID:28913455

  12. Is myelin basic protein a potential biomarker of brain cancer?

    PubMed

    Zavialova, M G; Shevchenko, V E; Nikolaev, E N; Zgoda, V G

    2017-08-01

    Myelin basic protein is a potential biomarker for the central nervous system diseases in which the myelin sheath is destroyed. Using pseudo-selected reaction monitoring and the method of standard additions, we have measured the myelin basic protein level in the cerebrospinal fluid of patients with neurotrauma (n = 6), chronic neurodegenerative diseases (n = 2) and brain cancer (n = 5). Myelin basic protein was detected only in four out of five cerebrospinal fluid samples of patients with brain cancer. The cerebrospinal fluid myelin basic protein level ranged from 3.7 to 8.8 ng ml -1 . We suggest that monitoring of myelin basic protein in cerebrospinal fluid can serve as a diagnostic test for the brain cancer.

  13. Diagnosing MS

    MedlinePlus

    ... diagnosis or provide additional evidence if it’s necessary. Magnetic Resonance Imaging (MRI) Diagnostic tool that currently offers the most ... Out Learn More Evoked Potentials (EP) Learn More Magnetic Resonance Imaging (MRI) Learn More Cerebrospinal Fluid (CSF) Learn More ...

  14. Implementation of an Algorithm for Prosthetic Joint Infection: Deviations and Problems.

    PubMed

    Mühlhofer, Heinrich M L; Kanz, Karl-Georg; Pohlig, Florian; Lenze, Ulrich; Lenze, Florian; Toepfer, Andreas; von Eisenhart-Rothe, Ruediger; Schauwecker, Johannes

    The outcome of revision surgery in arthroplasty is based on a precise diagnosis. In addition, the treatment varies based on whether the prosthetic failure is caused by aseptic or septic loosening. Algorithms can help to identify periprosthetic joint infections (PJI) and standardize diagnostic steps, however, algorithms tend to oversimplify the treatment of complex cases. We conducted a process analysis during the implementation of a PJI algorithm to determine problems and deviations associated with the implementation of this algorithm. Fifty patients who were treated after implementing a standardized algorithm were monitored retrospectively. Their treatment plans and diagnostic cascades were analyzed for deviations from the implemented algorithm. Each diagnostic procedure was recorded, compared with the algorithm, and evaluated statistically. We detected 52 deviations while treating 50 patients. In 25 cases, no discrepancy was observed. Synovial fluid aspiration was not performed in 31.8% of patients (95% confidence interval [CI], 18.1%-45.6%), while white blood cell counts (WBCs) and neutrophil differentiation were assessed in 54.5% of patients (95% CI, 39.8%-69.3%). We also observed that the prolonged incubation of cultures was not requested in 13.6% of patients (95% CI, 3.5%-23.8%). In seven of 13 cases (63.6%; 95% CI, 35.2%-92.1%), arthroscopic biopsy was performed; 6 arthroscopies were performed in discordance with the algorithm (12%; 95% CI, 3%-21%). Self-critical analysis of diagnostic processes and monitoring of deviations using algorithms are important and could increase the quality of treatment by revealing recurring faults.

  15. Diagnosis of multiple system atrophy.

    PubMed

    Palma, Jose-Alberto; Norcliffe-Kaufmann, Lucy; Kaufmann, Horacio

    2018-05-01

    Multiple system atrophy (MSA) may be difficult to distinguish clinically from other disorders, particularly in the early stages of the disease. An autonomic-only presentation can be indistinguishable from pure autonomic failure. Patients presenting with parkinsonism may be misdiagnosed as having Parkinson disease. Patients presenting with the cerebellar phenotype of MSA can mimic other adult-onset ataxias due to alcohol, chemotherapeutic agents, lead, lithium, and toluene, or vitamin E deficiency, as well as paraneoplastic, autoimmune, or genetic ataxias. A careful medical history and meticulous neurological examination remain the cornerstone for the accurate diagnosis of MSA. Ancillary investigations are helpful to support the diagnosis, rule out potential mimics, and define therapeutic strategies. This review summarizes diagnostic investigations useful in the differential diagnosis of patients with suspected MSA. Currently used techniques include structural and functional brain imaging, cardiac sympathetic imaging, cardiovascular autonomic testing, olfactory testing, sleep study, urological evaluation, and dysphagia and cognitive assessments. Despite advances in the diagnostic tools for MSA in recent years and the availability of consensus criteria for clinical diagnosis, the diagnostic accuracy of MSA remains sub-optimal. As other diagnostic tools emerge, including skin biopsy, retinal biomarkers, blood and cerebrospinal fluid biomarkers, and advanced genetic testing, a more accurate and earlier recognition of MSA should be possible, even in the prodromal stages. This has important implications as misdiagnosis can result in inappropriate treatment, patient and family distress, and erroneous eligibility for clinical trials of disease-modifying drugs. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Acute bacterial and viral meningitis.

    PubMed

    Bartt, Russell

    2012-12-01

    Most cases of acute meningitis are infectious and result from a potentially wide range of bacterial and viral pathogens. The organized approach to the patient with suspected meningitis enables the prompt administration of antibiotics, possibly corticosteroids, and diagnostic testing with neuroimaging and spinal fluid analysis. Acute meningitis is infectious in most cases and caused by a potentially wide range of bacterial and viral pathogens. Shifts in the epidemiology of bacterial pathogens have been influenced by changes in vaccines and their implementation. Seasonal and environmental changes influence the likely viral and rickettsial pathogens. The organized approach to the patient with suspected meningitis enables the prompt administration of antibiotics, possibly corticosteroids, and diagnostic testing with neuroimaging and spinal fluid analysis. Pertinent testing and treatment can vary with the clinical presentation, season, and possible exposures. This article reviews the epidemiology, clinical presentation, diagnosis, and treatment of acute meningitis.

  17. Update on community-acquired bacterial meningitis: guidance and challenges.

    PubMed

    van Ettekoven, C N; van de Beek, D; Brouwer, M C

    2017-09-01

    The existing heterogeneity in diagnostic work-up and treatment strategies in bacterial meningitis was the incentive to develop a European evidence-based guideline, which was published in 2016 by the European Society of Clinical Microbiology and Infectious Diseases (ESCMID) Study Group on Infections of the Brain (ESGIB). To summarize salient features of the guideline, identify recent developments and challenges currently faced. The ESCMID guideline, ongoing trial registries. Epidemiology, clinical symptoms, diagnostic work-up and therapy strategies of acute bacterial meningitis. The incidence of bacterial meningitis has decreased following pneumococcal and meningococcal conjugate vaccine introduction. In the diagnosis of bacterial meningitis the clinical characteristics and laboratory parameters are of limited diagnostic accuracy and therefore cerebrospinal fluid analysis remains the principal contributor to the final diagnosis. The ESCMID guideline advises to start empiric treatment within one hour of arrival in all suspected meningitis cases, and choice of antibiotics needs to be differentiated according to the patient's age, risk factors, and local resistance rates of pneumococci. Dexamethasone is the only proven adjunctive treatment and should be started together with the antibiotics. The follow-up of surviving patients should include evaluation for hearing loss and pneumococcal vaccination to prevent recurrences. Future perspectives include further development and implementation of vaccines, and new treatments aimed at further reducing the inflammatory response. Studies on implementation of the new guideline should determine adherence and evaluate whether improved prognosis can be achieved by following protocolled management strategies. Copyright © 2017 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  18. Enzymatic Fuel Cells: Towards Self-Powered Implantable and Wearable Diagnostics.

    PubMed

    Gonzalez-Solino, Carla; Lorenzo, Mirella Di

    2018-01-29

    With the rapid progress in nanotechnology and microengineering, point-of-care and personalised healthcare, based on wearable and implantable diagnostics, is becoming a reality. Enzymatic fuel cells (EFCs) hold great potential as a sustainable means to power such devices by using physiological fluids as the fuel. This review summarises the fundamental operation of EFCs and discusses the most recent advances for their use as implantable and wearable self-powered sensors.

  19. Diagnostic-Photographic Determination of Drag/Lift/Torque Coefficients of High Speed Rigid Body in Water Column

    DTIC Science & Technology

    2008-01-01

    various physical processes such as supercavitation and bubbles. A diagnostic- photographic method is developed in this study to determine the drag...nonlinear dynamics, body and multi-phase fluid interaction, supercavitation , and instability theory. The technical application of the hydrodynamics of...uV U ω= = − ×V e e e ei i , (29) where Eq.(9) is used. For a supercavitation area, a correction factor may be

  20. Enzymatic Fuel Cells: Towards Self-Powered Implantable and Wearable Diagnostics

    PubMed Central

    Gonzalez-Solino, Carla; Lorenzo, Mirella Di

    2018-01-01

    With the rapid progress in nanotechnology and microengineering, point-of-care and personalised healthcare, based on wearable and implantable diagnostics, is becoming a reality. Enzymatic fuel cells (EFCs) hold great potential as a sustainable means to power such devices by using physiological fluids as the fuel. This review summarises the fundamental operation of EFCs and discusses the most recent advances for their use as implantable and wearable self-powered sensors. PMID:29382147

  1. Cervical cerclage placement decreases local levels of proinflammatory cytokines in patients with cervical insufficiency.

    PubMed

    Monsanto, Stephany P; Daher, Silvia; Ono, Erika; Pendeloski, Karen Priscilla Tezotto; Trainá, Évelyn; Mattar, Rosiane; Tayade, Chandrakant

    2017-10-01

    Cervical insufficiency is characterized by premature, progressive dilation and shortening of the cervix during pregnancy. If left unattended, this can lead to the prolapse and rupture of the amniotic membrane, which usually results in midtrimester pregnancy loss or preterm birth. Previous studies have shown that proinflammatory cytokines such as interleukin-1β, interleukin-6, interleukin-8, and tumor necrosis factor alpha are up-regulated in normal parturition but are also associated with preterm birth. Studies evaluating such markers in patients with cervical insufficiency have evaluated only their diagnostic potential. Even fewer studies have studied them within the context of cerclage surgery. The objective of the study was to evaluate the impact of local and systemic inflammatory markers on the pathogenesis of cervical insufficiency and the effect of cerclage surgery on the local immune microenvironment of women with cervical insufficiency. We recruited 28 pregnant women (12-20 weeks' gestation) diagnosed with insufficiency and referred for cerclage surgery and 19 gestational age-matched normal pregnant women as controls. Serum and cervicovaginal fluid samples were collected before and after cerclage surgery and during a routine checkup for normal women and analyzed using a targeted 13-plex proinflammatory cytokine assay. Before surgery, patients with cervical insufficiency had higher levels of interleukin-1β, interleukin-6, interleukin-12, monocyte chemoattractant protein-1 and tumor necrosis factor alpha in cervicovaginal fluid compared to controls, but after surgery, these differences disappeared. No differences were found in serum of insufficiency versus control women. In patients with insufficiency, the levels of interleukin-1β, interleukin-6, interleukin-8, monocyte chemoattractant protein-1, and interferon gamma in cervicovaginal fluid declined significantly after cerclage compared with before intervention, but these changes were not detected in serum. Compared with normal women, patients with cervical insufficiency have elevated levels of proinflammatory cytokines in cervicovaginal fluid but not in serum, suggesting a dysregulation of the local immune environment. Cerclage intervention led to a significant decline in these proinflammatory cytokines, suggesting that cerclage may help reduce local inflammation in cervical insufficiency. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Clinical, ultrasonographic, and laboratory findings in 12 llamas and 12 alpacas with malignant round cell tumors

    PubMed Central

    Martin, Jeanne M.; Valentine, Beth A.; Cebra, Christopher K.

    2010-01-01

    Clinical signs, duration of illness, clinicopathologic findings, and ultrasonographic findings were evaluated in 12 llamas and 12 alpacas with malignant round cell tumors (MRCT). All but 1 animal died or was euthanized. Common clinical findings were anorexia, recumbency or weakness, and weight loss or poor growth. Peripheral lymphadenomegaly occurred in only 7 animals and was detected more often at necropsy than during physical examination. Common clinicopathologic abnormalities were hypoalbuminemia, acidosis, azotemia, anemia, hyperglycemia, and neutrophilia. Ultrasonography detected tumors in 4/6 animals. Cytologic evaluation of fluid or tissue aspirates or histopathology of biopsy tissue was diagnostic in 5/6 cases. A clinical course of 2 wk or less prior to death or euthanasia was more common in animals ≤ 2 y of age (9/11) than in older animals (6/13). Regular examination of camelids to include clinical pathology and evaluation of peripheral lymph nodes may result in early detection of MCRT. PMID:21358931

  3. Decompressive craniectomy and hydrocephalus: proposal of a therapeutic flow chart.

    PubMed

    Peraio, Simone; Calcagni, Maria Lucia; Mattoli, Maria Vittoria; Marziali, Giammaria; DE Bonis, Pasquale; Pompucci, Angelo; Anile, Carmelo; Mangiola, Annunziato

    2017-12-01

    Decompressive craniectomy (DC) may be necessary to save the lives of patients suffering from intracranial hypertension. However, this procedure is not complication-free. Its two main complications are hydrocephalus and the sinking skin-flap syndrome (SSFS). The radiological findings and the clinical evaluation may be not enough to decide when and/or how to treat hydrocephalus in a decompressed patient. SSFS and hydrocephalus may be not unrelated. In fact, a patient affected by hydrocephalus, after the ventriculo-peritoneal shunt, can develop SSFS; on the other hand, SSFS per se can cause hydrocephalus. Treating hydrocephalus in decompressed patients can be challenging. Radiological findings and clinical evaluation may not be enough to define the most appropriate therapeutic strategy. Cerebrospinal fluid (CSF) dynamics and metabolic evaluations can represent important diagnostic tools for assessing the need of a CSF shunt in patients with a poor baseline neurologic status. Based on our experience, we propose a flow chart for treating decompressed patients affected by ventriculomegaly.

  4. Evaluation of the intercept oral specimen collection device with HIV assays versus paired serum/plasma specimens.

    PubMed

    Beelaert, G; Van Heddegem, L; Van Frankenhuijsen, M; Vandewalle, G; Compernolle, V; Florence, E; Fransen, K

    2016-08-01

    Oral fluid has many advantages over blood-based techniques: it is less invasive, eliminates the occupational risk associated with needle stick accidents and collection can be self-administrated. Each individual test is packaged with a corresponding collection device. This study tested the suitability of the Intercept Oral Specimen Collection Device for different HIV diagnostic tests: three different rapid HIV tests and two adapted ELISAs, which were evaluated and compared with a gold standard on blood. In addition a total IgG quantification was performed to demonstrate the quality of the specimen. HIV antibodies were detected with a sensitivity of 100%, 99.3%, 98.6%, 100% and 95.7% for, DPP, OraQuick, Aware, Genscreen and Vironostika respectively using the Intercept Collection Device. Respective specificities were 100%, 100%, 99.3%, 97.3% and 100%. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Measuring (1,3)-β-D-glucan in tracheal aspirate, bronchoalveolar lavage fluid, and serum for detection of suspected Candida pneumonia in immunocompromised and critically ill patients: a prospective observational study.

    PubMed

    Su, Kang-Cheng; Chou, Kun-Ta; Hsiao, Yi-Han; Tseng, Ching-Min; Su, Vincent Yi-Fong; Lee, Yu-Chin; Perng, Diahn-Warng; Kou, Yu Ru

    2017-04-08

    While Candida pneumonia is life-threatening, biomarker measurements to early detect suspected Candida pneumonia are lacking. This study compared the diagnostic values of measuring levels of (1, 3)-β-D-glucan in endotracheal aspirate, bronchoalveolar lavage fluid, and serum to detect suspected Candida pneumonia in immunocompromised and critically ill patients. This prospective, observational study enrolled immunocompromised, critically ill, and ventilated patients with suspected fungal pneumonia in mixed intensive care units from November 2010 to October 2011. Patients with D-glucan confounding factors or other fungal infection were excluded. Endotracheal aspirate, bronchoalveolar lavage fluid and serum were collected from each patient to perform a fungal smear, culture, and D-glucan assay. After screening 166 patients, 31 patients completed the study and were categorized into non-Candida pneumonia/non-candidemia (n = 18), suspected Candida pneumonia (n = 9), and non-Candida pneumonia/candidemia groups (n = 4). D-glucan levels in endotracheal aspirate or bronchoalveolar lavage were highest in suspected Candida pneumonia, while the serum D-glucan level was highest in non-Candida pneumonia/candidemia. In all patients, the D-glucan value in endotracheal aspirate was positively correlated with that in bronchoalveolar lavage fluid. For the detection of suspected Candida pneumonia, the predictive performance (sensitivity/specificity/D-glucan cutoff [pg/ml]) of D-glucan in endotracheal aspirate and bronchoalveolar lavage fluid was 67%/82%/120 and 89%/86%/130, respectively, accounting for areas under the receiver operating characteristic curve of 0.833 and 0.939 (both P < 0.05), respectively. Measuring serum D-glucan was of no diagnostic value (area under curve =0.510, P = 0.931) for the detection of suspected Candida pneumonia in the absence of concurrent candidemia. D-glucan levels in both endotracheal aspirate and bronchoalveolar lavage, but not in serum, provide good diagnostic values to detect suspected Candida pneumonia and to serve as potential biomarkers for early detection in this patient population.

  6. Preanalytical Confounding Factors in the Analysis of Cerebrospinal Fluid Biomarkers for Alzheimer’s Disease: The Issue of Diurnal Variation

    PubMed Central

    Cicognola, Claudia; Chiasserini, Davide; Parnetti, Lucilla

    2015-01-01

    Given the growing use of cerebrospinal fluid (CSF) beta-amyloid (Aβ) and tau as biomarkers for early diagnosis of Alzheimer’s disease (AD), it is essential that the diagnostic procedures are standardized and the results comparable across different laboratories. Preanalytical factors are reported to be the cause of at least 50% of the total variability. Among them, diurnal variability is a key issue and may have an impact on the comparability of the values obtained. The available studies on this issue are not conclusive so far. Fluctuations of CSF biomarkers in young healthy volunteers have been previously reported, while subsequent studies have not confirmed those observations in older subjects, the ones most likely to receive this test. The observed differences in circadian rhythms need to be further assessed not only in classical CSF biomarkers but also in novel forthcoming biomarkers. In this review, the existing data on the issue of diurnal variations of CSF classical biomarkers for AD will be analyzed, also evaluating the available data on new possible biomarkers. PMID:26175714

  7. Real-Time Polymerase Chain Reaction Detection of Angiostrongylus cantonensis DNA in Cerebrospinal Fluid from Patients with Eosinophilic Meningitis.

    PubMed

    Qvarnstrom, Yvonne; Xayavong, Maniphet; da Silva, Ana Cristina Aramburu; Park, Sarah Y; Whelen, A Christian; Calimlim, Precilia S; Sciulli, Rebecca H; Honda, Stacey A A; Higa, Karen; Kitsutani, Paul; Chea, Nora; Heng, Seng; Johnson, Stuart; Graeff-Teixeira, Carlos; Fox, LeAnne M; da Silva, Alexandre J

    2016-01-01

    Angiostrongylus cantonensis is the most common infectious cause of eosinophilic meningitis. Timely diagnosis of these infections is difficult, partly because reliable laboratory diagnostic methods are unavailable. The aim of this study was to evaluate the usefulness of a real-time polymerase chain reaction (PCR) assay for the detection of A. cantonensis DNA in human cerebrospinal fluid (CSF) specimens. A total of 49 CSF specimens from 33 patients with eosinophilic meningitis were included: A. cantonensis DNA was detected in 32 CSF specimens, from 22 patients. Four patients had intermittently positive and negative real-time PCR results on subsequent samples, indicating that the level of A. cantonensis DNA present in CSF may fluctuate during the course of the illness. Immunodiagnosis and/or supplemental PCR testing supported the real-time PCR findings for 30 patients. On the basis of these observations, this real-time PCR assay can be useful to detect A. cantonensis in the CSF from patients with eosinophilic meningitis. © The American Society of Tropical Medicine and Hygiene.

  8. The Gingival Crevicular Fluid as a Source of Biomarkers to Enhance Efficiency of Orthodontic and Functional Treatment of Growing Patients.

    PubMed

    de Aguiar, Mariana Caires Sobral; Perinetti, Giuseppe; Capelli, Jonas

    2017-01-01

    Gingival crevicular fluid (GCF) is a biological exudate and quantification of its constituents is a current method to identify specific biomarkers with reasonable sensitivity for several biological events. Studies are being performed to evaluate whether the GCF biomarkers in growing subjects reflect both the stages of individual skeletal maturation and the local tissue remodeling triggered by orthodontic force. Present evidence is still little regarding whether and which GCF biomarkers are correlated with the growth phase (mainly pubertal growth spurt), while huge investigations have been reported on several GCF biomarkers (for inflammation, tissue damage, bone deposition and resorption, and other biological processes) in relation to the orthodontic tooth movement. In spite of these investigations, the clinical applicability of the method is still limited with further data needed to reach a full diagnostic utility of specific GCF biomarkers in orthodontics. Future studies are warranted to elucidate the role of main GCF biomarkers and how they can be used to enhance functional treatment, optimize orthodontic force intensity, or prevent major tissue damage consequent to orthodontic treatment.

  9. The Gingival Crevicular Fluid as a Source of Biomarkers to Enhance Efficiency of Orthodontic and Functional Treatment of Growing Patients

    PubMed Central

    Capelli, Jonas

    2017-01-01

    Gingival crevicular fluid (GCF) is a biological exudate and quantification of its constituents is a current method to identify specific biomarkers with reasonable sensitivity for several biological events. Studies are being performed to evaluate whether the GCF biomarkers in growing subjects reflect both the stages of individual skeletal maturation and the local tissue remodeling triggered by orthodontic force. Present evidence is still little regarding whether and which GCF biomarkers are correlated with the growth phase (mainly pubertal growth spurt), while huge investigations have been reported on several GCF biomarkers (for inflammation, tissue damage, bone deposition and resorption, and other biological processes) in relation to the orthodontic tooth movement. In spite of these investigations, the clinical applicability of the method is still limited with further data needed to reach a full diagnostic utility of specific GCF biomarkers in orthodontics. Future studies are warranted to elucidate the role of main GCF biomarkers and how they can be used to enhance functional treatment, optimize orthodontic force intensity, or prevent major tissue damage consequent to orthodontic treatment. PMID:28232938

  10. The Heidelberg Appendicitis Score Predicts Perforated Appendicitis in Children.

    PubMed

    Boettcher, Michael; Günther, Patrick; Breil, Thomas

    2017-10-01

    In the future, surgical management of pediatric appendicitis might become limited to nonperforating appendicitis. Thus, it becomes increasingly important to differentiate advanced from simple appendicitis and to predict perforated appendicitis among a group of children with right-sided abdominal pain, which was the aim of this study. An institutionally approved, single-center retrospective analysis of all patients with appendectomy from January 2009 to December 2010 was conducted. All diagnostic aspects were evaluated to identify predictors and differentiators of perforated appendicitis. In 2 years, 157 children suffered from appendicitis. Perforation occurred in 47 (29.9%) of the patients. C-reactive protein (CRP) levels higher than 20 mg/dL ( P = .037) and free abdominal fluid on ultrasonography ( P = .031) are the most important features to differentiate perforated from simple appendicitis. Moreover, all children with perforation had a positive Heidelberg Appendicitis Score (HAS). A negative HAS excludes perforation in all cases (negative predictive value = 100%). Perforated appendicitis can be ruled out by the HAS. In a cohort with right-sided abdominal pain, perforation should be considered in children with high CRP levels and free fluids or abscess formation on ultrasound.

  11. [Forensic medical characteristic of the thermal injury caused by inflammation of combustible fluids].

    PubMed

    Khushkadamov, Z K; Iskhizova, L N; Gornostaev, D V

    2012-01-01

    The diagnostics of thermal injuries caused by inflammation of combustible fluids should be based on the comprehensive assessment of the results of examination of the scene of the accident, autopsy studies, forensic chemical expertise, and analysis of the circumstances of the case and/or medical documentation. Special attention should be given to the choice of adequate methods for taking samples to be used in forensic chemical studies. The assessment of thermal injuries caused by inflammation of combustible fluids must take into consideration the time and conditions under which they were inflicted (e.g. closed or open space, vertical or horizontal position, etc.).

  12. Psychobiology of the amniotic environment.

    PubMed

    Benassi, Luigi; Accorsi, Francesca; Marconi, Lorenza; Benassi, Gianluca

    2004-01-01

    Water, basic element of amniotic fluid (A.F.), is closely related to Life, Fertility and Motherhood in several cultures and religions. Through material evidences of an essential growth medium and useful diagnostic source, a new concept grow up: the fluid as a first real environment in which fetus lives and acts. Many studies confirm that in A.F. fetus starts his character-building, his memory and his intelligence. The fluid seems to be the first means of learning and acknowledgement. Sounds, smells and tastes are perceived as well as emotions and fears. Urinoterapy and staminal cells sampling shows how A.F. can be considered as an additional terapeutic resource.

  13. Acute postretinal blindness: ophthalmologic, neurologic, and magnetic resonance imaging findings in dogs and cats (seven cases).

    PubMed

    Seruca, Cristina; Ródenas, Sergio; Leiva, Marta; Peña, Teresa; Añor, Sònia

    2010-09-01

    To describe the ophthalmologic, neurologic, and magnetic resonance imaging (MRI) findings of seven animals with acute postretinal blindness as sole neurologic deficit. Medical records were reviewed to identify dogs and cats with postretinal blindness of acute presentation, that had a cranial MRI performed as part of the diagnostic workup. Only animals lacking other neurologic signs at presentation were included. Complete physical, ophthalmic, and neurologic examinations, routine laboratory evaluations, thoracic radiographs, abdominal ultrasound, electroretinography, and brain MRI were performed in all animals. Cerebrospinal fluid analysis and postmortem histopathologic results were recorded when available. Four dogs and three cats met the inclusion criteria. Lesions affecting the visual pathways were observed on magnetic resonance (MR) images in six cases. Location, extension, and MRI features were described. Neuroanatomic localization included: olfactory region with involvement of the optic chiasm (n = 4), pituitary fossa with involvement of the optic chiasm and optic tracts (n = 1), and optic nerves (n = 1). Of all lesions detected, five were consistent with intracranial tumors (two meningiomas, one pituitary tumor, two nasal tumors with intracranial extension), and one with bilateral optic neuritis that was confirmed by cerebrospinal fluid analysis. Histologic diagnosis was obtained in four cases and included one meningioma, one pituitary carcinoma, one nasal osteosarcoma, and one nasal carcinoma. Central nervous system (CNS) disease should be considered in dogs and cats with acute blindness, even when other neurologic deficits are absent. This study emphasizes the relevance of MRI as a diagnostic tool for detection and characterization of CNS lesions affecting the visual pathways.

  14. Usefulness of Two Aspergillus PCR Assays and Aspergillus Galactomannan and β-d-Glucan Testing of Bronchoalveolar Lavage Fluid for Diagnosis of Chronic Pulmonary Aspergillosis.

    PubMed

    Urabe, Naohisa; Sakamoto, Susumu; Sano, Go; Suzuki, Junko; Hebisawa, Akira; Nakamura, Yasuhiko; Koyama, Kazuya; Ishii, Yoshikazu; Tateda, Kazuhiro; Homma, Sakae

    2017-06-01

    We evaluated the usefulness of an Aspergillus galactomannan (GM) test, a β-d-glucan (βDG) test, and two different Aspergillus PCR assays of bronchoalveolar lavage fluid (BALF) samples for the diagnosis of chronic pulmonary aspergillosis (CPA). BALF samples from 30 patients with and 120 patients without CPA were collected. We calculated the sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio for each test individually and in combination with other tests. The optical density index values, as determined by receiver operating characteristic analysis, for the diagnosis of CPA were 0.5 and 100 for GM and βDG testing of BALF, respectively. The sensitivity and specificity of the GM test, βDG test, and PCR assays 1 and 2 were 77.8% and 90.0%, 77.8% and 72.5%, 86.7% and 84.2%, and 66.7% and 94.2%, respectively. A comparison of the PCR assays showed that PCR assay 1 had a better sensitivity, a better negative predictive value, and a better negative likelihood ratio and PCR assay 2 had a better specificity, a better positive predictive value, and a better positive likelihood ratio. The combination of the GM and βDG tests had the highest diagnostic odds ratio. The combination of the GM and βDG tests on BALF was more useful than any single test for diagnosing CPA. Copyright © 2017 American Society for Microbiology.

  15. The Burn Wound Exudate – an under-utilized resource

    PubMed Central

    Widgerow, Alan D; King, Kassandra; Tussardi, Ilaria Tocco; Banyard, Derek A.; Chiang, Ryan; Awad, Antony; Afzel, Hassan; Bhatnager, Shweta; Melkumyan, Satenik; Wirth, Garrett; Evans, Gregory R.D

    2014-01-01

    Introduction The burn wound exudate represents the burn tissue microenvironment. Extracting information from the exudate relating to cellular components, signaling mediators and protein content can provide much needed data relating to the local tissue damage, depth of the wound and probable systemic complications. This review examines the scientific data extracted from burn wound exudates over the years and proposes new investigations that will provide useful information from this underutilized resource. Method A literature review was conducted using the electronic database PubMed to search for literature pertaining to burn wound or blister fluid analysis. Key words included burn exudate, blister fluid, wound exudate, cytokine burn fluid, subeschar fluid, cytokine burns, serum cytokines. 32 relevant article were examined and 29 selected as relevant to the review. 3 papers were discarded due to questionable methodology or conclusions. The reports were assessed for their affect on management decisions and diagnostics. Furthermore, traditional blood level analysis of these mediators was made to compare the accuracy of blood versus exudate in burn wound management. Extrapolations are made for new possibilities of burn wound exudate analysis. Results Studies pertaining to burn wound exudate, subeschar fluid and blister fluid analyses may have contributed to burn wound management decisions particularly related to escharectomies and early burn wound excision. In addition, information from these studies have the potential to impact on areas such as healing, scarring, burn wound conversion and burn wound depth analysis. Conclusion Burn wound exudate analysis has proven useful in burn wound management decisions. It appears to offer a far more accurate reflection of the burn wound pathophysiology than the traditional blood/serum investigations undertaken in the past. New approaches to diagnostics and treatment efficacy assessment are possible utilizing data from this fluid. Burn wound exudate is a useful, currently under-utilized resource that is likely to take a more prominent role in burn wound management. PMID:24986597

  16. High sensitivity and specificity in proposed clinical diagnostic criteria for anti-N-methyl-D-aspartate receptor encephalitis.

    PubMed

    Ho, Alvin C C; Mohammad, Shekeeb S; Pillai, Sekhar C; Tantsis, Esther; Jones, Hannah; Ho, Reena; Lim, Ming; Hacohen, Yael; Vincent, Angela; Dale, Russell C

    2017-12-01

    To determine the validity of the proposed clinical diagnostic criteria for anti-N-methyl-d-aspartate receptor (NMDAR) encephalitis in paediatric patients. The diagnostic criteria for anti-NMDAR encephalitis proposed by Graus et al. (2016) use clinical features and conventional investigations to facilitate early immunotherapy before antibody status is available. The criteria are satisfied if patients develop four out of six symptom groups within 3 months, together with at least one abnormal investigation (electroencephalography/cerebrospinal fluid) and reasonable exclusion of other disorders. We evaluated the validity of the criteria using a retrospective cohort of paediatric patients with encephalitis. Twenty-nine patients with anti-NMDAR encephalitis and 74 comparison children with encephalitis were included. As expected, the percentage of patients with anti-NMDAR encephalitis who fulfilled the clinical criteria increased over time. During the hospital inpatient admission, most patients (26/29, 90%) with anti-NMDAR encephalitis fulfilled the criteria, significantly more than the comparison group (3/74, 4%) (p<0.001). The median time of fulfilling the criteria in patients with anti-NMDAR encephalitis was 2 weeks from first symptom onset (range 1-6). The sensitivity of the criteria was 90% (95% confidence interval 73-98) and the specificity was 96% (95% confidence interval 89-99). The proposed diagnostic criteria for anti-NMDAR encephalitis have good sensitivity and specificity. Incomplete criteria do not exclude the diagnosis. The proposed clinical diagnostic criteria for anti-N-methyl-d-aspartate receptor (NMDAR) encephalitis by Graus et al. (2016) have high sensitivity and specificity in paediatric patients. The median time of fulfilling the criteria in patients with anti-NMDAR was 2 weeks from first symptom onset. © 2017 Mac Keith Press.

  17. Gastric band slippage: a case-controlled study comparing new and old radiographic signs of this important surgical complication.

    PubMed

    Swenson, David W; Pietryga, Jason A; Grand, David J; Chang, Kevin J; Murphy, Brian L; Egglin, Thomas K

    2014-07-01

    The purpose of this study was to compare the diagnostic performance of four radiographic signs of gastric band slippage: abnormal phi angle, the "O sign," inferior displacement of the superolateral gastric band margin, and presence of an air-fluid level above the gastric band. A search of the electronic medical record identified 21 patients with a surgically proven slipped gastric band and 63 randomly-selected asymptomatic gastric band patients who had undergone barium swallow studies. These studies were evaluated for the four signs of band slippage by two independent radiologists who were blinded to clinical data. Sensitivity, specificity, and positive and negative predictive values were calculated for each radiographic sign of band slippage. Interobserver agreement between radiologists was assessed using the Fleiss kappa statistic. In evaluating for gastric band slippage, an abnormal phi angle greater than 58° was 91-95% sensitive and 52-62% specific (κ = 0.78), the O sign was 33-48% sensitive but 97% specific (κ = 0.84), inferior displacement of the superolateral band margin by more than 2.4 cm from the diaphragm was 95% sensitive and 97-98% specific (κ = 0.97), and the presence of an air-fluid level was 95% sensitive and 100% specific (κ = 1.00). We report two previously undescribed radiographic signs of gastric band slippage that are both sensitive and specific for this important surgical complication and recommend that these signs should be incorporated into the imaging evaluation of gastric band patients.

  18. Species and temperature measurement in H2/O2 rocket flow fields by means of Raman scattering diagnostics

    NASA Technical Reports Server (NTRS)

    De Groot, Wim A.; Weiss, Jonathan M.

    1992-01-01

    Validation of CFD codes developed for prediction and evaluation of rocket performance is hampered by a lack of experimental data. Nonintrusive laser based diagnostics are needed to provide spatially and temporally resolved gas dynamic and fluid dynamic measurements. This paper reports the first nonintrusive temperature and species measurements in the plume of a 110 N gaseous hydrogen/oxygen thruster at and below ambient pressures, obtained with spontaneous Raman spectroscopy. Measurements at 10 mm downstream of the exit plane are compared with predictions from a numerical solution of the axisymmetric Navier-Stokes and species transport equations with chemical kinetics, which fully model the combustor-nozzle-plume flowfield. The experimentally determined oxygen number density at the centerline at 10 mm downstream of the exit plane is four times that predicted by the model. The experimental number density data fall between those numerically predicted for the exit and 10 mm downstream planes in both magnitude and radial gradient. The predicted temperature levels are within 10 to 15 percent of measured values.

  19. The choice of amniotic fluid in metabolomics for the monitoring of fetus health.

    PubMed

    Palmas, Francesco; Fattuoni, Claudia; Noto, Antonio; Barberini, Luigi; Dessì, Angelica; Fanos, Vassilios

    2016-01-01

    Amniotic fluid (AF) is a biological fluid in which metabolite transport is regulated by the placenta, the permeable skin, fetal lung egress and gastric fluid. During pregnancy, the composition of AF changes from similar to the interstitial fluid of the mother, to a more complex system, influenced by the fetus's urine. Since AF reflects the mother's and the fetus's health status at the same time, it may be an important diagnostic tool for a wider spectrum of clinical conditions. Indeed, the metabolic characterization of AF in relation to pathological occurrences may lead to the discovery of new biomarkers for a better clinical practice. For this reason, metabolomics may be the most suitable strategy for this task. In this review, research works on metabolomic AF analysis are discussed according to the morbidity of interest, being preterm birth/labor, gestational age and diabetes and fetal malformations, along with a number of other important studies.

  20. Comparative analysis of the diagnostic performance of crude sheep hydatid cyst fluid, purified antigen B and its subunit (12 Kda), assessed by ELISA, in the diagnosis of human cystic echinococcosis.

    PubMed

    Tawfeek, Gihan M; Elwakil, Hala S; El-Hoseiny, Laila; Thabet, Hala S; Sarhan, Rania M; Awad, Nabil S; Anwar, Wagida A

    2011-02-01

    The diagnosis of patients with cystic echinococcosis (CE) by means of serology has a limited support in clinical practice due to cross-reactivity with other helminthes leading to overestimation of the parasite's true prevalence. A wealth of reports on the diagnostic performance of antigen B (AgB) has been produced. This study was designed to comparatively assess the diagnostic efficacy of crude sheep hydatid cyst fluid (HCF), AgB and its subunit (12 KDa) to detect IgG or IgG4 antibodies in CE patients' sera using enzyme-linked immunosorbent assay (ELISA).The best diagnostic performance was obtained with anti-HCF IgG ELISA which gave 92.4% sensitivity and 92.6% specificity. Despite the low sensitivity of anti AgB IgG ELISA (84%), it gave the best specificity (94.4%) with less cross-reaction with sera of subjects infected with other parasites. In conclusion, it is recommended to use anti-HCF IgG ELISA for initial screening in large seroprevalence studies. Further analysis of positive serum samples with anti AgB IgG ELISA would allow the confirmation of true positives. Specific IgG4 ELISA may represent a complementary assay, useful as secondary confirmatory tests for patients with suspected CE and negative for total IgG ELISA.

  1. [Diagnostic performance of T-SPOT.TB on peripheral blood in combination with adenosine deaminase on pleural fluid for the diagnosis of tuberculous pleurisy within different age group].

    PubMed

    Xu, H Y; Zhang, D Q; Ye, J R; Su, S S; Xie, Y P; Chen, C S; Li, Y P

    2017-06-27

    Objective: To evaluate the performance of T cell enzyme-linked immuno-spot assay (T-SPOT) on peripheral blood in combination with adenosine deaminase (ADA) on pleural fluid for diagnosis of tuberculous (TB) pleurisy within different age groups. Methods: The data of patients with pleural effusion from the Department of Pulmonary and Critical Care Medicine of the First Affiliated Hospital of Wenzhou Medical University from April 2012 to November 2016 were retrospectively analyzed, and the diagnoses of these patients were histopathologically confirmed through medical thoracoscopy. The cases who had confirmed diagnosis, in the same time, received peripheral blood T-SPOT.TB were enrolled. The performance of peripheral blood T-SPOT.TB in combination with pleural fluid ADA on diagnosing TB pleurisy in the younger patients (16-59 years old) and elderly patients (≥60 years old) were analyzed respectively. The sensitivity, specificity and the receiver operating characteristic (ROC) curve were adopted for statistical analysis. Results: A total of 448 cases were finally enrolled, 341(76.1%) confirmed with TB pleurisy, 224 males, 117 females, (47±19) years old; and 107 (23.9%) classified as non-TB pleurisy, 65 males, 42 females, (61±14) years old. There were 285 cases who were classified as younger group, and the other 163 cases were classified as elderly group. The sensitivity and specificity of peripheral blood T-SPOT.TB were 85.4% (204/239) and 71.7% (33/46) in the younger patients, 76.5% (78/102) and 59.0% (36/61) respectively in the elderly patients. The sensitivity of peripheral blood T-SPOT.TB in the younger patients was significantly higher than that in the elderly patients ( P =0.047). The sensitivity and specificity were 99.2% and 95.7% in combination with peripheral blood T-SPOT.TB and pleural fluid ADA respectively in the younger patients. The area under ROC curve (AUC) of T-SPOT.TB in the younger patients was 0.833, AUC of T-SPOT.TB combined with ADA was 0.911. The combination test of 2 tests had the sensitivity of 96.1% and the specificity of 90.2% respectively in the elderly patients. The AUC of T-SPOT.TB in the elderly patients was 0.747, AUC of T-SPOT.TB combined with ADA was 0.911. Conclusion: Peripheral blood T-SPOT.TB combined with pleural fluid ADA can improve the diagnostic performance for TB pleurisy with different ages, especially for elderly patients who can't tolerate pleural biopsy.

  2. An investigation of matched index of refraction technique and its application in optical measurements of fluid flow

    NASA Astrophysics Data System (ADS)

    Amini, Noushin; Hassan, Yassin A.

    2012-12-01

    Optical distortions caused by non-uniformities of the refractive index within the measurement volume is a major impediment for all laser diagnostic imaging techniques applied in experimental fluid dynamic studies. Matching the refractive indices of the working fluid and the test section walls and interfaces provides an effective solution to this problem. The experimental set-ups designed to be used along with laser imaging techniques are typically constructed of transparent solid materials. In this investigation, different types of aqueous salt solutions and various organic fluids are studied for refractive index matching with acrylic and fused quartz, which are commonly used in construction of the test sections. One aqueous CaCl2·2H2O solution (63 % by weight) and two organic fluids, Dibutyl Phthalate and P-Cymene, are suggested for refractive index matching with fused quartz and acrylic, respectively. Moreover, the temperature dependence of the refractive indices of these fluids is investigated, and the Thermooptic Constant is calculated for each fluid. Finally, the fluid viscosity for different shear rates is measured as a function of temperature and is applied to characterize the physical behavior of the proposed fluids.

  3. The oral-systemic connection: role of salivary diagnostics

    NASA Astrophysics Data System (ADS)

    Malamud, Daniel

    2013-05-01

    Utilizing saliva instead of blood for diagnosis of both local and systemic health is a rapidly emerging field. Recognition of oral-systemic interrelationships for many diseases has fostered collaborations between medicine and dentistry, and many of these collaborations rely on salivary diagnostics. The oral cavity is easily accessed and contains most of the analytes present in blood. Saliva and mucosal transudate are generally utilized for oral diagnostics, but gingival crevicular fluid, buccal swabs, dental plaque and volatiles may also be useful depending on the analyte being studied. Examples of point-of-care devices capable of detecting HIV, TB, and Malaria targets are being developed and discussed in this overview.

  4. Acute hemorrhagic diarrhea syndrome associated with contaminated foreign bodies (used feminine hygiene products) in a Golden Retriever dog

    PubMed Central

    YANG, Seung-Il; KIM, Jung-Hyun; JEONG, Soon-Wuk; HAN, Hyun-Jung

    2018-01-01

    A one-year-old male Golden Retriever presented with acute onset of vomiting and hemorrhagic diarrhea since 2 days. The dog was depressed, showing abdominal pain, 12% dehydration, tachycardia, and a bounding pulse. Diagnostic imaging showed severe dilatation and fluid retention of the entire gastrointestinal tract with decreased motility. A foreign body was found in the gastroduodenal region, but there was no obstruction or plication. The dog was tentatively diagnosed with acute hemorrhagic diarrhea syndrome and rapidly recovered after supportive treatment. However, on the morning of day 4, anorexia and vomiting recurred, and diagnostic imaging revealed intestinal plication with free peritoneal fluid, not found on the previous image. An emergency laparotomy revealed the foreign body to be two used feminine hygiene products. These contaminated products were suspected to induce acute hemorrhagic diarrhea syndrome, and led to subsequent complication in this large dog. PMID:29459505

  5. Acute hemorrhagic diarrhea syndrome associated with contaminated foreign bodies (used feminine hygiene products) in a Golden Retriever dog.

    PubMed

    Yang, Seung-Il; Kim, Jung-Hyun; Jeong, Soon-Wuk; Han, Hyun-Jung

    2018-04-18

    A one-year-old male Golden Retriever presented with acute onset of vomiting and hemorrhagic diarrhea since 2 days. The dog was depressed, showing abdominal pain, 12% dehydration, tachycardia, and a bounding pulse. Diagnostic imaging showed severe dilatation and fluid retention of the entire gastrointestinal tract with decreased motility. A foreign body was found in the gastroduodenal region, but there was no obstruction or plication. The dog was tentatively diagnosed with acute hemorrhagic diarrhea syndrome and rapidly recovered after supportive treatment. However, on the morning of day 4, anorexia and vomiting recurred, and diagnostic imaging revealed intestinal plication with free peritoneal fluid, not found on the previous image. An emergency laparotomy revealed the foreign body to be two used feminine hygiene products. These contaminated products were suspected to induce acute hemorrhagic diarrhea syndrome, and led to subsequent complication in this large dog.

  6. Methods and means of Fourier-Stokes polarimetry and the spatial-frequency filtering of phase anisotropy manifestations in endometriosis diagnostics

    NASA Astrophysics Data System (ADS)

    Ushenko, A. G.; Dubolazov, O. V.; Ushenko, Vladimir A.; Ushenko, Yu. A.; Sakhnovskiy, M. Yu.; Prydiy, O. G.; Lakusta, I. I.; Novakovskaya, O. Yu.; Melenko, S. R.

    2016-12-01

    This research presents investigation results of diagnostic efficiency of a new azimuthally stable Mueller-matrix method of laser autofluorescence coordinate distributions analysis of dried polycrystalline films of uterine cavity peritoneal fluid. A new model of generalized optical anisotropy of biological tissues protein networks is proposed in order to define the processes of laser autofluorescence. The influence of complex mechanisms of both phase anisotropy (linear birefringence and optical activity) and linear (circular) dichroism is taken into account. The interconnections between the azimuthally stable Mueller-matrix elements characterizing laser autofluorescence and different mechanisms of optical anisotropy are determined. The statistic analysis of coordinate distributions of such Mueller-matrix rotation invariants is proposed. Thereupon the quantitative criteria (statistic moments of the 1st to the 4th order) of differentiation of dried polycrystalline films of peritoneal fluid - group 1 (healthy donors) and group 2 (uterus endometriosis patients) are estimated.

  7. Cautious Application of Pleural N-Terminal Pro-B-Type Natriuretic Peptide in Diagnosis of Congestive Heart Failure Pleural Effusions among Critically Ill Patients

    PubMed Central

    Yeh, Jiann-Horng; Huang, Chun-Ta; Liu, Chia-Hsiung; Ruan, Sheng-Yuan; Tsai, Yi-Ju; Chien, Ying-Chun; Yang, Ching-Yao; Huang, Chun-Kai; Hsu, Chia-Lin; Kuo, Lu-Cheng; Lee, Pei-Lin; Ku, Shih-Chi; Kuo, Ping-Hung; Yu, Chong-Jen

    2014-01-01

    Background and Objective Several studies on diagnostic accuracy of pleural N-terminal pro-B-type natriuretic peptide (NT-pro-BNP) for effusions from congestive heart failure (CHF) conclude that pleural NT-pro-BNP is a useful biomarker with high diagnostic accuracy for distinguishing CHF effusions. However, its applicability in critical care settings remains uncertain and requires further investigations. Methods NT-proBNP was measured in pleural fluid samples of a prospective cohort of intensive care unit patients with pleural effusions. Receiver operating characteristic curve analysis was performed to determine diagnostic accuracy of pleural NT-proBNP for prediction of CHF effusions. Results One hundred forty-seven critically ill patients were evaluated, 38 (26%) with CHF effusions and 109 (74%) with non-CHF effusions of various causes. Pleural NT-proBNP levels were significantly elevated in patients with CHF effusions. Pleural NT-pro-BNP demonstrated the area under the curve of 0.87 for diagnosing effusions due to CHF. With a cutoff of 2200 pg/mL, pleural NT-proBNP displayed high sensitivity (89%) but moderate specificity (73%). Notably, 29 (27%) of 109 patients with non-CHF effusions had pleural NT-proBNP levels >2200 pg/mL and these patients were more likely to experience septic shock (18/29 vs. 10/80, P<0.001) or acute kidney injury (19/29 vs. 9/80, P<0.001). Conclusions Among critically ill patients, pleural NT-proBNP measurements remain a useful diagnostic aid in evaluation of pleural effusions. However, patients with non-CHF effusions may exhibit high pleural NT-proBNP concentrations if they suffer from septic shock or acute kidney injury. Accordingly, it is suggested that clinical context should be taken into account when interpreting pleural NT-proBNP values in critical care settings. PMID:25502236

  8. Diagnostic imaging for chronic plantar heel pain: a systematic review and meta-analysis

    PubMed Central

    2009-01-01

    Background Chronic plantar heel pain (CPHP) is a generalised term used to describe a range of undifferentiated conditions affecting the plantar heel. Plantar fasciitis is reported as the most common cause and the terms are frequently used interchangeably in the literature. Diagnostic imaging has been used by many researchers and practitioners to investigate the involvement of specific anatomical structures in CPHP. These observations help to explain the underlying pathology of the disorder, and are of benefit in forming an accurate diagnosis and targeted treatment plan. The purpose of this systematic review was to investigate the diagnostic imaging features associated with CPHP, and evaluate study findings by meta-analysis where appropriate. Methods Bibliographic databases including Medline, Embase, CINAHL, SportDiscus and The Cochrane Library were searched electronically on March 25, 2009. Eligible articles were required to report imaging findings in participants with CPHP unrelated to inflammatory arthritis, and to compare these findings with a control group. Methodological quality was evaluated by use of the Quality Index as described by Downs and Black. Meta-analysis of study data was conducted where appropriate. Results Plantar fascia thickness as measured by ultrasonography was the most widely reported imaging feature. Meta-analysis revealed that the plantar fascia of CPHP participants was 2.16 mm thicker than control participants (95% CI = 1.60 to 2.71 mm, P < 0.001) and that CPHP participants were more likely to have plantar fascia thickness values greater than 4.0 mm (OR = 105.11, 95% CI = 3.09 to 3577.28, P = 0.01). CPHP participants were also more likely to show radiographic evidence of subcalcaneal spur than control participants (OR = 8.52, 95% CI = 4.08 to 17.77, P < 0.001). Conclusion This systematic review has identified 23 studies investigating the diagnostic imaging appearance of the plantar fascia and inferior calcaneum in people with CPHP. Analysis of these studies found that people with CPHP are likely to have a thickened plantar fascia with associated fluid collection, and that thickness values >4.0 mm are diagnostic of plantar fasciitis. Additionally, subcalcaneal spur formation is strongly associated with pain beneath the heel. PMID:19912628

  9. Major depressive disorder: insight into candidate cerebrospinal fluid protein biomarkers from proteomics studies.

    PubMed

    Al Shweiki, Mhd Rami; Oeckl, Patrick; Steinacker, Petra; Hengerer, Bastian; Schönfeldt-Lecuona, Carlos; Otto, Markus

    2017-06-01

    Major Depressive Disorder (MDD) is the leading cause of global disability, and an increasing body of literature suggests different cerebrospinal fluid (CSF) proteins as biomarkers of MDD. The aim of this review is to summarize the suggested CSF biomarkers and to analyze the MDD proteomics studies of CSF and brain tissues for promising biomarker candidates. Areas covered: The review includes the human studies found by a PubMed search using the following terms: 'depression cerebrospinal fluid biomarker', 'major depression biomarker CSF', 'depression CSF biomarker', 'proteomics depression', 'proteomics biomarkers in depression', 'proteomics CSF biomarker in depression', and 'major depressive disorder CSF'. The literature analysis highlights promising biomarker candidates and demonstrates conflicting results on others. It reveals 42 differentially regulated proteins in MDD that were identified in more than one proteomics study. It discusses the diagnostic potential of the biomarker candidates and their association with the suggested pathologies. Expert commentary: One ultimate goal of finding biomarkers for MDD is to improve the diagnostic accuracy to achieve better treatment outcomes; due to the heterogeneous nature of MDD, using bio-signatures could be a good strategy to differentiate MDD from other neuropsychiatric disorders. Notably, further validation studies of the suggested biomarkers are still needed.

  10. Acute kidney injury—an overview of diagnostic methods and clinical management

    PubMed Central

    Hertzberg, Daniel; Rydén, Linda; Pickering, John W.; Sartipy, Ulrik

    2017-01-01

    Abstract Acute kidney injury (AKI) is a common condition in multiple clinical settings. Patients with AKI are at an increased risk of death, over both the short and long term, and of accelerated renal impairment. As the condition has become more recognized and definitions more unified, there has been a rapid increase in studies examining AKI across many different clinical settings. This review focuses on the classification, diagnostic methods and clinical management that are available, or promising, for patients with AKI. Furthermore, preventive measures with fluids, acetylcysteine, statins and remote ischemic preconditioning, as well as when dialysis should be initiated in AKI patients are discussed. The classification of AKI includes both changes in serum creatinine concentrations and urine output. Currently, no kidney injury biomarkers are included in the classification of AKI, but proposals have been made to include them as independent diagnostic markers. Treatment of AKI is aimed at addressing the underlying causes of AKI, and at limiting damage and preventing progression. The key principles are: to treat the underlying disease, to optimize fluid balance and optimize hemodynamics, to treat electrolyte disturbances, to discontinue or dose-adjust nephrotoxic drugs and to dose-adjust drugs with renal elimination. PMID:28616210

  11. Adenocarcinoma of urinary bladder: A report of two patients.

    PubMed

    Kumari, Nitu; Vasudeva, Pawan; Kumar, Anup; Agrawal, Usha

    2015-01-01

    Adenocarcinoma of the bladder is a rare tumor. Primary and metastatic adenocarcinomas of urinary bladder are morphologically similar, but histogenetically different. We present two cases, a signet ring cell adenocarcinoma with follow-up and another of glandular adenocarcinoma of urinary bladder. Pathological evaluation and immunohistochemical panel of eight markers (E-cadherin, CK20, CK7, CDX2, estrogen receptor (ER), gross cystic disease fluid protein 15 (GCDFP15), 34bE12, and prostate specific antigen (PSA) provides a diagnostic confirmation of primary adenocarcinoma with the positive expression of E-cadherin and CK20 in case 1 and metastatic adenocarcinoma of prostate with profile of E-cadherin+, CK20-, GCDFP15+, 34bE12+, and PSA+ in case 2.

  12. LLE review. Volume 61, Quarterly report, October--December 1994

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1994-12-31

    This volume of the LLE review, covering the period of October--December 1994, contains articles on a diagnostic method employing krypton spectroscopy for measurement of temperature and shell-fuel mixing in high-temperature implosions; the first direct assessment of the ion-acoustic decay instability in a large-scale length, hot plasma; measurements of polarization mode dispersion and group-velocity walkaway in birefringent media using a frequency domain interferometer; an evaluation of the magnetic flux dynamics occurring in an optically triggered, thin-film superconducting switch; the effect of slurry fluid chemistry on particle size distribution during aqueous polishing of optical glass; and the influence of thermal and mechanicalmore » processing history in the preparation of well-ordered liquid crystal elastomer systems.« less

  13. Low thrust rocket test facility

    NASA Technical Reports Server (NTRS)

    Arrington, Lynn A.; Schneider, Steven J.

    1990-01-01

    A low thrust chemical rocket test facility has recently become operational at the NASA-Lewis. The new facility is used to conduct both long duration and performance tests at altitude over a thruster's operating envelope using hydrogen and oxygen gas for propellants. The facility provides experimental support for a broad range of objectives, including fundamental modeling of fluids and combustion phenomena, the evaluation of thruster components, and life testing of full rocket designs. The major mechanical and electrical systems are described along with aspects of the various optical diagnostics available in the test cell. The electrical and mechanical systems are designed for low down time between tests and low staffing requirements for test operations. Initial results are also presented which illustrate the various capabilities of the cell.

  14. Comparison of synovial fluid culture and 16S rRNA PCR in dogs with suspected septic arthritis.

    PubMed

    Scharf, V F; Lewis, D D; Wellehan, J F; Wamsley, H L; Richardson, R

    2015-06-01

    To prospectively compare the sensitivity and specificity of 16S rRNA PCR with culture for identifying the causative organism in synovial fluid obtained from dogs with suspected septic arthritis. Synovial fluid cytology, PCR analysis and aerobic, anaerobic and Mycoplasma culture of samples from the affected joints of 18 dogs presenting with suspected septic arthritis were performed. Synovial fluid samples from the corresponding contralateral joints of 7 dogs were also analysed as negative controls. There was no significant difference between the sensitivity of bacterial detection via culture (63.2%) versus PCR (73.7%) of synovial fluid (P=0.728) or between culture and combined PCR and culture (89.5%) of synovial fluid (P=0.124). The specificity of PCR (42.9%) was significantly lower than culture specificity (100%) (P=0.07). Although 16S PCR may hold potential as an ancillary diagnostic test for identifying the causative organism in dogs with septic arthritis, our study failed to demonstrate improved accuracy compared with traditional synovial fluid culture. © 2015 Australian Veterinary Association.

  15. [Dental periimplantitis distinctive features diagnostic in cases of minimal thyroid insufficiency].

    PubMed

    Shcherbakov, M V; Golovina, E S; Gil'miiarova, F N

    2008-01-01

    There were disclosed syndrome of minimal thyroid insufficiency in each fourth patient with dental periimplantitis and absence of thyroid gland dysfunction in case of mucositis of periimplantitis origin. The data were presented of minimal thyroid insufficiency manifestations in cases of inflammatory complications of dental implantations the indicator of which was the content of overall and free thyroxin in oral fluid. There were determined common and differentiating peculiarities of oral fluid homeostasis in cases of dental periimplantitis and mucositis of periimplantitis origin.

  16. Evaluation of a newly designed sandwich enzyme linked immunosorbent assay for the detection of hydatid antigen in serum, urine and cyst fluid for diagnosis of cystic echinococcosis.

    PubMed

    Chaya, Dr; Parija, Subhash Chandra

    2013-07-01

    Cystic echinococcosis (CE) is a zoonotic disease of humans with variable clinical manifestations. Imaging and immunological methods are currently the mainstay of diagnosis of this disease. Although the immunological tests for detection of anti-echinococcal antibodies have several disadvantages, they are widely being used. Antigen is far more superior than antibody detection test as they can provide a specific parasitic diagnosis. A sandwich enzyme linked immunosorbent assay (ELISA) was designed using antibodies to 24 kDa urinary hydatid antigen for the detection of hydatid antigens in urine, serum and cyst fluid specimens. The performance of this novel test was compared with that of other hydatid antibody detection ELISA and enzyme immune transfer blot (EITB) using radiological and surgical confirmation as the gold standard. The antigen detection ELISA showed 100% sensitivity and specificity when tested with cyst fluid. On testing urine and serum, the antigen detection ELISA was found to be more specific than antibody detection ELISA. EITB was found to be the most sensitive and specific test. ELISA using polyclonal antibodies against 24 kDa urinary hydatid protein was moderately sensitive to detect hydatid antigen in serum and urine. Hence polyclonal antibodies to 24 kDa urinary hydatid antigen can be used as an alternative source of antibody to detect hydatid antigen in serum, urine and cyst fluid. In the present study, EITB was found to be highly specific test for detection of hydatid antibodiesin serum. 24 kDa protein was found to be specific and of diagnostic value in CE.

  17. Evaluation of a rapid diagnostic test for the detection of Burkholderia pseudomallei in the Lao People's Democratic Republic.

    PubMed

    Woods, Kate L; Boutthasavong, Latsaniphone; NicFhogartaigh, Caoimhe; Lee, Sue J; Davong, Viengmon; AuCoin, David P; Dance, David A B

    2018-05-02

    Burkholderia pseudomallei causes significant global morbidity and mortality, with the highest disease burden in parts of Asia where culture-based diagnosis is often not available. We prospectively evaluated the Active Melioidosis Detect (AMD, InBios International, USA) lateral flow immunoassay (LFI) for rapid detection of B. pseudomallei in turbid blood cultures, pus, sputum, sterile fluid, urine, and sera. Performance was compared to B. pseudomallei detection using monoclonal antibody latex agglutination (LA) and immunofluorescence assays (IFA), with culture as the gold standard. AMD was 99% (99/100; 94.6 - 100%) sensitive and 100% (308/308; 98.8-100%) specific on turbid blood culture bottles, with no difference to LA or IFA. AMD specificity was 100% on pus (122/122; 97.0-100%), sputum (20/20; 83.2-100%), and sterile fluid (44/44; 92 - 100%). Sensitivity on these samples was: pus 47.1% (8/17; 23.0 - 72.2%), sputum 33.3% (1/3; 0.84 - 90.6%), and sterile fluid 0% (0/2; 0 - 84.2%). Urine AMD had a positive predictive value of 94% (32/34; 79.7 - 98.5%) for diagnosing melioidosis in our cohort. AMD sensitivity on stored sera, collected prospectively from melioidosis cases during this study, was 13.9% (5/36; 4.7% - 29.5%) when compared to blood culture samples taken on the same day. In conclusion, the AMD is an excellent tool for rapid diagnosis of melioidosis from turbid blood cultures, and maintains specificity across all sample types. It is a promising tool for urinary antigen detection, which could revolutionise diagnosis of melioidosis in resource-limited settings. Further work is required to improve sensitivity on non-blood culture samples. Copyright © 2018 Woods et al.

  18. Clinical features and pathological joint changes in dogs with erosive immune-mediated polyarthritis: 13 cases (2004–2012)

    PubMed Central

    Shaughnessy, Magen L.; Sample, Susannah J.; Abicht, Carter; Heaton, Caitlin; Muir, Peter

    2017-01-01

    OBJECTIVE To evaluate the clinical features and pathological joint changes in dogs with erosive immune-mediated polyarthritis (IMPA). DESIGN Retrospective case series. ANIMALS 13 dogs with erosive IMPA and 66 dogs with nonerosive IMPA. PROCEDURES The medical record database of a veterinary teaching hospital was reviewed to identify dogs with IMPA that were examined between October 2004 and December 2012. For each IMPA-affected dog, information extracted from the medical record included signalment, diagnostic test results, radiographic findings, and treatments administered. Dogs were classified as having erosive IMPA if review of radiographs revealed the presence of bone lysis in multiple joints, and descriptive data were generated for those dogs. All available direct smears of synovial fluid samples underwent cytologic evaluation. The synovial fluid total nucleated cell count and WBC differential were estimated and compared between dogs with erosive IMPA and dogs with nonerosive IMPA. RESULTS 13 of 79 (16%) dogs had erosive IMPA. Dogs with erosive IMPA had a mean ± SD age of 7.1 ± 2.4 years and bodyweight of 8.3 ± 3.4 kg (18.3 ± 7.5 lb). All 13 dogs had erosive lesions in their carpal joints. The estimated median synovial fluid lymphocyte count for dogs with erosive IMPA was significantly greater than that for dogs with nonerosive IMPA. All dogs received immunosuppressive therapy with leflunomide (n = 9), prednisone (3), or prednisone-azathioprine (1). CONCLUSIONS AND CLINICAL RELEVANCE Results indicated erosive IMPA most commonly affected the carpal joints of middle-aged small-breed dogs. Further genetic analyses and analysis of lymphocyte-subsets is warranted for dogs with erosive IMPA. Word count = 256 PMID:27823373

  19. Clinical features and pathological joint changes in dogs with erosive immune-mediated polyarthritis: 13 cases (2004-2012).

    PubMed

    Shaughnessy, Magen L; Sample, Susannah J; Abicht, Carter; Heaton, Caitlin; Muir, Peter

    2016-11-15

    OBJECTIVE To evaluate the clinical features and pathological joint changes in dogs with erosive immune-mediated polyarthritis (IMPA). DESIGN Retrospective case series. ANIMALS 13 dogs with erosive IMPA and 66 dogs with nonerosive IMPA. PROCEDURES The medical record database of a veterinary teaching hospital was reviewed to identify dogs with IMPA that were examined between October 2004 and December 2012. For each IMPA-affected dog, information extracted from the medical record included signalment, diagnostic test results, radiographic findings, and treatments administered. Dogs were classified as having erosive IMPA if review of radiographs revealed the presence of bone lysis in multiple joints, and descriptive data were generated for those dogs. All available direct smears of synovial fluid samples underwent cytologic evaluation. The synovial fluid total nucleated cell count and WBC differential count were estimated and compared between dogs with erosive IMPA and dogs with nonerosive IMPA. RESULTS 13 of 79 (16%) dogs had erosive IMPA. Dogs with erosive IMPA had a mean ± SD age of 7.1 ± 2.4 years and body weight of 8.3 ± 3.4 kg (18.3 ± 7.5 lb). All 13 dogs had erosive lesions in their carpal joints. The estimated median synovial fluid lymphocyte count for dogs with erosive IMPA was significantly greater than that for dogs with nonerosive IMPA. All dogs received immunosuppressive therapy with leflunomide (n = 9), prednisone (3), or prednisone-azathioprine (1). CONCLUSIONS AND CLINICAL RELEVANCE Results indicated erosive IMPA most commonly affected the carpal joints of middle-aged small-breed dogs. Further genetic analyses and analysis of lymphocyte-subsets are warranted for dogs with erosive IMPA.

  20. A Comparative Histopathology, Serology and Molecular Study, on Experimental Ocular Toxocariasis by Toxocara cati in Mongolian Gerbils and Wistar Rats

    PubMed Central

    Zibaei, Mohammad; Sadjjadi, Seyed Mahmoud; Karamian, Mehdi; Uga, Shoji; Oryan, Ahmad; Jahadi-Hosseini, Seyed Hamidreza

    2013-01-01

    The aim of this study was to compare the performance of three in-house diagnostic tests, that is, histopathology, enzyme-linked immunosorbent assay (ELISA), and polymerase chain reaction (PCR), for the diagnosis after experimental infection with Toxocara cati. Twenty Mongolian gerbils and Wistar rats were divided into ten groups (n = 2/group). Toxocara cati infections were established in Mongolian gerbils and Wistar rats by administering doses of 240 and 2500 embryonated Toxocara cati eggs by gavage, respectively. Tissue sections were stained with Haematoxylin and Eosin and observed under the light microscope. Sera and vitreous fluid collected from separate infected groups were tested against Toxocara cati antigens, for 92 days postinfection. Genomic DNA was extracted from formalin-fixed paraffin-embedded (FFPE) blocks, and aqueous fluids belong to the animals. The histopathology test gave negative results among the groups of animals examined between 5 and 92 days postinfection. The ELISA results showed that anti-Toxocara antibodies have risen between 7 and 61 days postinfection in sera and vitreous fluid in the animals infected, respectively. Analysis of PCR products revealed positive band (660 bp) in the orbital tissue infected Mongolian gerbils at 5 days postinfection. Of the three evaluated methods, the PCR could be recommended for scientific and laboratory diagnoses of toxocariasis in experimentally infected animals. PMID:24069585

  1. A comparative histopathology, serology and molecular study, on experimental ocular toxocariasis by Toxocara cati in Mongolian gerbils and Wistar rats.

    PubMed

    Zibaei, Mohammad; Sadjjadi, Seyed Mahmoud; Karamian, Mehdi; Uga, Shoji; Oryan, Ahmad; Jahadi-Hosseini, Seyed Hamidreza

    2013-01-01

    The aim of this study was to compare the performance of three in-house diagnostic tests, that is, histopathology, enzyme-linked immunosorbent assay (ELISA), and polymerase chain reaction (PCR), for the diagnosis after experimental infection with Toxocara cati. Twenty Mongolian gerbils and Wistar rats were divided into ten groups (n = 2/group). Toxocara cati infections were established in Mongolian gerbils and Wistar rats by administering doses of 240 and 2500 embryonated Toxocara cati eggs by gavage, respectively. Tissue sections were stained with Haematoxylin and Eosin and observed under the light microscope. Sera and vitreous fluid collected from separate infected groups were tested against Toxocara cati antigens, for 92 days postinfection. Genomic DNA was extracted from formalin-fixed paraffin-embedded (FFPE) blocks, and aqueous fluids belong to the animals. The histopathology test gave negative results among the groups of animals examined between 5 and 92 days postinfection. The ELISA results showed that anti-Toxocara antibodies have risen between 7 and 61 days postinfection in sera and vitreous fluid in the animals infected, respectively. Analysis of PCR products revealed positive band (660 bp) in the orbital tissue infected Mongolian gerbils at 5 days postinfection. Of the three evaluated methods, the PCR could be recommended for scientific and laboratory diagnoses of toxocariasis in experimentally infected animals.

  2. Lectin-induced agglutination method of urinary exosomes isolation followed by mi-RNA analysis: Application for prostate cancer diagnostic.

    PubMed

    Samsonov, Roman; Shtam, Tatiana; Burdakov, Vladimir; Glotov, Andrey; Tsyrlina, Evgenia; Berstein, Lev; Nosov, Alexander; Evtushenko, Vladimir; Filatov, Michael; Malek, Anastasia

    2016-01-01

    Prostate cancer is the most common cancer in men. Prostate-specific antigen has, however, insufficient diagnostic specificity. Novel complementary diagnostic approaches are greatly needed. MiRNAs are small regulatory RNAs which play an important role in tumorogenesis and are being investigated as a cancer biomarker. In addition to their intracellular regulatory functions, miRNAs are secreted into the extracellular space and can be found in various body fluids, including urine. The stability of extracellular miRNAs is defined by association with proteins, lipoprotein particles, and membrane vesicles. Among the known forms of miRNA packaging, tumour-derived exosome-enclosed miRNAs is thought to reflect the vital activity of cancer cells. The assessment of the exosomal fraction of urinary miRNA may present a new and highly specific method for prostate cancer diagnostics; however, this is challenged by the absence of reliable and inexpensive methods for isolation of exosomes. Prostate cancer (PC) cell lines and urine samples collected from 35 PC patients and 35 healthy donors were used in the study. Lectins, phytohemagglutinin, and concanavalin A were used to induce agglutination of exosomes. The efficiency of isolation process was evaluated by AFM and DLS assays. The protein content of isolated exosomes was analysed by western blotting. Exosomal RNA was assayed by automated electrophoresis and expression level of selected miRNAs was evaluated by RT-qPCR. The diagnostic potency of the urinary exosomal miRNA assessment was estimated by the ROC method. The formation of multi-vesicular agglutinates in urine can be induced by incubation with lectin at a final concentration of 2 mg/ml. These agglutinates contain urinary exosomes and may be pelleted by centrifugation with a relatively low G-force. The analysis of PC-related miRNA in urinary exosomes revealed significant up-regulation of miR-574-3p, miR-141-5p, and miR-21-5p associated with PC. Lectin-induced aggregation is a low-cost and easily performed method for isolation of exosomes from urine. Isolated exosomes can be further analysed in terms of miRNA content. The miRNA profile of urinary exosomes reflects development of prostate cancer and may present a promising diagnostic tool. © 2015 Wiley Periodicals, Inc.

  3. FLUID-STRUCTURE INTERACTION MODELS OF THE MITRAL VALVE: FUNCTION IN NORMAL AND PATHOLOGIC STATES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kunzelman, K. S.; Einstein, Daniel R.; Cochran, R. P.

    2007-08-29

    Successful mitral valve repair is dependent upon a full understanding of normal and abnormal mitral valve anatomy and function. Computational analysis is one such method that can be applied to simulate mitral valve function in order to analyze the roles of individual components, and evaluate proposed surgical repair. We developed the first three-dimensional, finite element (FE) computer model of the mitral valve including leaflets and chordae tendineae, however, one critical aspect that has been missing until the last few years was the evaluation of fluid flow, as coupled to the function of the mitral valve structure. We present here ourmore » latest results for normal function and specific pathologic changes using a fluid-structure interaction (FSI) model. Normal valve function was first assessed, followed by pathologic material changes in collagen fiber volume fraction, fiber stiffness, fiber splay, and isotropic stiffness. Leaflet and chordal stress and strain, and papillary muscle force was determined. In addition, transmitral flow, time to leaflet closure, and heart valve sound were assessed. Model predictions in the normal state agreed well with a wide range of available in-vivo and in-vitro data. Further, pathologic material changes that preserved the anisotropy of the valve leaflets were found to preserve valve function. By contrast, material changes that altered the anisotropy of the valve were found to profoundly alter valve function. The addition of blood flow and an experimentally driven microstructural description of mitral tissue represent significant advances in computational studies of the mitral valve, which allow further insight to be gained. This work is another building block in the foundation of a computational framework to aid in the refinement and development of a truly noninvasive diagnostic evaluation of the mitral valve. Ultimately, it represents the basis for simulation of surgical repair of pathologic valves in a clinical and educational setting.« less

  4. Clinical evaluation of a loop-mediated isothermal amplification (LAMP) assay for rapid detection of Neisseria meningitidis in cerebrospinal fluid.

    PubMed

    Lee, DoKyung; Kim, Eun Jin; Kilgore, Paul E; Kim, Soon Ae; Takahashi, Hideyuki; Ohnishi, Makoto; Anh, Dang Duc; Dong, Bai Qing; Kim, Jung Soo; Tomono, Jun; Miyamoto, Shigehiko; Notomi, Tsugunori; Kim, Dong Wook; Seki, Mitsuko

    2015-01-01

    Neisseria meningitidis (Nm) is a leading causative agent of bacterial meningitis in humans. Traditionally, meningococcal meningitis has been diagnosed by bacterial culture. However, isolation of bacteria from patients' cerebrospinal fluid (CSF) is time consuming and sometimes yields negative results. Recently, polymerase chain reaction (PCR)-based diagnostic methods of detecting Nm have been considered the gold standard because of their superior sensitivity and specificity compared with culture. In this study, we developed a loop-mediated isothermal amplification (LAMP) method and evaluated its ability to detect Nm in cerebrospinal fluid (CSF). We developed a meningococcal LAMP assay (Nm LAMP) that targets the ctrA gene. The primer specificity was validated using 16 strains of N. meningitidis (serogroup A, B, C, D, 29-E, W-135, X, Y, and Z) and 19 non-N. meningitidis species. Within 60 min, the Nm LAMP detected down to ten copies per reaction with sensitivity 1000-fold more than that of conventional PCR. The LAMP assays were evaluated using a set of 1574 randomly selected CSF specimens from children with suspected meningitis collected between 1998 and 2002 in Vietnam, China, and Korea. The LAMP method was shown to be more sensitive than PCR methods for CSF samples (31 CSF samples were positive by LAMP vs. 25 by PCR). The detection rate of the LAMP method was substantially higher than that of the PCR method. In a comparative analysis of the PCR and LAMP assays, the clinical sensitivity, specificity, positive predictive value, and negative predictive value of the LAMP assay were 100%, 99.6%, 80.6%, and 100%, respectively. Compared to PCR, LAMP detected Nm with higher analytical and clinical sensitivity. This sensitive and specific LAMP method offers significant advantages for screening patients on a population basis and for diagnosis in clinical settings.

  5. Epidemiology of meningitis with a negative CSF Gram stain: under-utilization of available diagnostic tests.

    PubMed

    Nesher, L; Hadi, C M; Salazar, L; Wootton, S H; Garey, K W; Lasco, T; Luce, A M; Hasbun, R

    2016-01-01

    Meningitis with a negative cerebrospinal fluid Gram stain (CSF-GS) poses a diagnostic challenge as more than 50% of patients remain without an aetiology. The introduction of polymerase chain reaction (PCR) and arboviral serologies have increased diagnostic capabilities, yet large scale epidemiological studies evaluating their use in clinical practice are lacking. We conducted a prospective observational study in New Orleans between November 1999 and September 2008 (early era) when PCR was not widely available, and in Houston between November 2008 and June 2013 (modern era), when PCR was commonly used. Patients presenting with meningitis and negative CSF-GS were followed for 4 weeks. All investigations, PCR used, and results were recorded as they became available. In 323 patients enrolled, PCR provided the highest diagnostic yield (24·2%) but was ordered for 128 (39·6%) patients; followed by serology for arboviruses (15%) that was ordered for 100 (31%) of all patients. The yield of blood cultures was (10·3%) and that of CSF cultures was 4%; the yield for all other tests was <10%. Overall, 65% of the patients remained without a diagnosis at 4 weeks: 72·1% in early era vs. 53·4% (P < 0·01) in modern era; this change was attributed to diagnosing more viral pathogens, 8·3% and 26·3% (P < 0·01), respectively. The introduction of PCR and arboviral serologies has improved the yield of diagnosing patients with meningitis and a negative CSF-GS, but both tests are being under-utilized.

  6. Monoclonal antibodies against LipL32, the major outer membrane protein of pathogenic Leptospira: production, characterization, and testing in diagnostic applications.

    PubMed

    Fernandes, Cláudia P H; Seixas, Fabiana K; Coutinho, Mariana L; Vasconcellos, Flávia A; Seyffert, Núbia; Croda, Julio; McBride, Alan J; Ko, Albert I; Dellagostin, Odir A; Aleixo, José A G

    2007-02-01

    Pathogenic serovars of Leptospira have a wide antigenic diversity attributed mainly to the lipopolysaccharide present in the outer membrane. In contrast, antigens conserved among pathogenic serovars are mainly represented by outer membrane proteins. Surface exposure of a major and highly conserved outer membrane lipoprotein (LipL32) was recently demonstrated on pathogenic Leptospira. LipL32 in its recombinant form (rLipL32) was used to immunize BALB/c mice to develop murine monoclonal antibodies (MAbs). Three MAbs against rLipL32 were produced, isotyped, and evaluated for further use in diagnostic tests of leptospirosis using different approaches. MAbs were conjugated to peroxidase and evaluated in a native protein enzyme-linked immunosorbent assay (ELISA) with intact and heat-treated leptospiral cells, conjugated to fluorescein isothiocyanate (FITC) for indirect immunofluorescence with intact and methanol fixed cells and were used for LipL32 immunoprecipitation from leptospiral cells. rLipL32 MAbs conjugated to peroxidase or used as primary antibody bound to intact and heat-treated cells in ELISA, proving that they could be used in enzyme immunoassays for detection of the native protein. In immunofluorescence assay, MAbs labeled bacterial cells either intact or methanol fixed. Two MAbs were able to immunoprecipitate the native protein from live and motile leptospiral cells and, adsorbed onto magnetic beads, captured intact bacteria from artificially contaminated human sera for detection by polymerase chain reaction (PCR) amplification. Results of this study suggest that the MAbs produced can be useful for the development of diagnostic tests based on detection of LipL32 leptospiral antigen in biological fluids.

  7. Diagnostic Yield and Safety of Brain Biopsy for Suspected Primary Central Nervous System Angiitis.

    PubMed

    Torres, Jose; Loomis, Caitlin; Cucchiara, Brett; Smith, Michelle; Messé, Steven

    2016-08-01

    The utility and safety of brain biopsy for suspected primary angiitis of the central nervous system (PACNS) are uncertain. Factors predictive of a positive biopsy have not been well described. Our aim was to evaluate the diagnostic yield and safety of brain biopsy in suspected PACNS and determine whether any prebiopsy variables are associated with a positive biopsy. This is a retrospective study of consecutive patients who underwent diagnostic brain biopsy for PACNS at a single institution. The relationship between biopsy yield and patient demographics, surgical technique, laboratory testing, neuroimaging, biopsy characteristics, and prebiopsy immunosuppressive therapy were examined. PACNS was confirmed in 9 of 79 patients (11%). Biopsy identified alternative diagnoses in 24 patients (30%), with cerebral amyloid angiopathy (8 patients), encephalitis (5 patients), demyelination (3 patients), and CNS lymphoma (3 patients) most commonly found. There was no correlation between a positive biopsy and cerebrospinal fluid results, neuroimaging, surgical technique, biopsy characteristics, or preoperative immunosuppressive therapy. Smaller biopsies (P=0.02) and closed procedures (P=0.013) were less likely to yield a diagnosis. Postoperative complications occurred in 13 patients (16%), 3 (4%) of which were serious. Brain biopsy leads to pathological confirmation of vasculitis in a minority of suspected PACNS cases but alternative diagnoses are often identified. Importantly, rare but meaningful complications may occur. © 2016 American Heart Association, Inc.

  8. Diagnosing Chronic Pancreatitis.

    PubMed

    Anaizi, Ahmad; Hart, Phil A; Conwell, Darwin L

    2017-07-01

    Diagnosing CP can range from routine in those with severe disease and obvious calcifications on CT imaging to elusive in those patients with early changes in CP. The workup of suspected CP should follow a progressively noninvasive to more invasive STEP-wise approach in a patient with a suspicious clinical presentation and risk factors that raise their pretest probability of disease. After a thorough history and physical examination, basic laboratories should be obtained such as lipase, amylase, metabolic panel, and indirect PFTs (fecal elastase-1, serum trypsin). Computed tomography remains the best initial imaging modality to obtain as it has good sensitivity for severe CP and may obviate the need for other diagnostic tests. When equivocal, an MRCP should be obtained for a more detailed evaluation of the both the pancreatic parenchyma and ducts. If the diagnosis remains in doubt, EUS should be performed with or without pancreas function testing. ERCP remains a last-line diagnostic test and seldom should be used outside of therapeutic purposes. Future advances should target optimizing current diagnostic tools to more accurately diagnose early CP, as it is in this population where the benefits of delaying progression of CP may have the most profound effect. Likely the best way at establishing a diagnosis in these patients is via pancreatic function testing in the setting of indeterminate EUS results. Biomarker studies of pancreas fluid may supplement diagnosis.

  9. Fluid Structure Interaction of Parachutes in Supersonic Planetary Entry

    NASA Technical Reports Server (NTRS)

    Sengupta, Anita

    2011-01-01

    A research program to provide physical insight into disk-gap-band parachute operation in the supersonic regime on Mars was conducted. The program included supersonic wind tunnel tests, computational fluid dynamics and fluid structure interaction simulations. Specifically, the nature and cause of the "area oscillation" phenomenon were investigated to determine the scale, aerodynamic, and aero-elastic dependence of the supersonic parachute collapse and re-inflation event. A variety of non-intrusive, temporally resolved, and high resolution diagnostic techniques were used to interrogate the flow and generate validation datasets. The results of flow visualization, particle image velocimetry, load measurements, and photogrammetric reconstruction will be presented. Implications to parachute design, use, and verification will also be discussed.

  10. Spironolactone reduces severity of obstructive sleep apnoea in patients with resistant hypertension: a preliminary report.

    PubMed

    Gaddam, K; Pimenta, E; Thomas, S J; Cofield, S S; Oparil, S; Harding, S M; Calhoun, D A

    2010-08-01

    Obstructive sleep apnoea (OSA) and hyperaldosteronism are very common in subjects with resistant hypertension. We hypothesized that aldosterone-mediated chronic fluid retention may influence OSA severity in patients with resistant hypertension. We tested this in an open-label evaluation by assessing the changes in the severity of OSA in patients with resistant hypertension after treatment with spironolactone. Subjects with resistant hypertension (clinical blood pressure (BP) >or=140/90 mm Hg on >or=3 antihypertensive medications, including a thiazide diuretic and OSA (defined as an apnoea-hypopnoea index (AHI) >or=15) had full diagnostic, polysomnography before and 8 weeks after spironolactone (25-50 mg a day) was added to their ongoing antihypertensive therapy. In all, 12 patients (mean age 56 years and body mass index 36.8 kg m(-2)) were evaluated. After treatment with spironolactone, the AHI (39.8+/-19.5 vs 22.0+/-6.8 events/h; P<0.05) and hypoxic index (13.6+/-10.8 vs 6.7+/-6.6 events/h; P<0.05), weight and clinic and ambulatory BP were significantly reduced. Plasma renin activity (PRA) and serum creatinine were significantly higher. This study provides preliminary evidence that treatment with a mineralocorticoid receptor antagonist substantially reduces the severity of OSA. If confirmed in a randomized assessment, it will support aldosterone-mediated chronic fluid retention as an important mediator of OSA severity in patients with resistant hypertension.

  11. Diagnosis of antenatal Bartter syndrome.

    PubMed

    Narayan, R; Peres, M; Kesby, G

    2016-01-01

    Bartter syndrome is a rare heterogeneous group of autosomal-recessive salt-losing renal tubular disorders that can present in fetal life (antenatal Bartter syndrome; ABS) as "unexplained" early-onset polyhydramnios, often associated with growth restriction. Prenatal diagnosis of the condition involves assessment of amniotic fluid biochemistry in a setting of polyuric polyhydramnios; with elevated chloride levels considered a consistent and diagnostic finding. Other amniotic fluid biochemical markers have been described, notably increased aldosterone levels, and low total protein levels. NOVEL INSIGHT: Antenatal Bartter syndrome is a heterogeneous group of renal disorders. While certain biochemical features in amniotic fluid might heighten suspicion, final diagnosis can only be made in the postnatal setting. In the setting of unexplained severe polyhydramnios, clinicians should continue to entertain the diagnosis of antenatal Bartter Syndrome and maintain neonatal surveillance, even if amniotic fluid markers do not support the diagnosis.

  12. Bioluminescence methods for enzymatic determinations

    DOEpatents

    Bostick, William D.; Denton, Mark S.; Dinsmore, Stanley R.

    1982-01-01

    An enzymatic method for continuous, on-line and rapid detection of diagnostically useful biomarkers, which are symptomatic of disease or trauma-related tissue damage, is disclosed. The method is characterized by operability on authentic samples of complex biological fluids which contain the biomarkers.

  13. Design criteria for developing low-resource magnetic bead assays using surface tension valves

    PubMed Central

    Adams, Nicholas M.; Creecy, Amy E.; Majors, Catherine E.; Wariso, Bathsheba A.; Short, Philip A.; Wright, David W.; Haselton, Frederick R.

    2013-01-01

    Many assays for biological sample processing and diagnostics are not suitable for use in settings that lack laboratory resources. We have recently described a simple, self-contained format based on magnetic beads for extracting infectious disease biomarkers from complex biological samples, which significantly reduces the time, expertise, and infrastructure required. This self-contained format has the potential to facilitate the application of other laboratory-based sample processing assays in low-resource settings. The technology is enabled by immiscible fluid barriers, or surface tension valves, which stably separate adjacent processing solutions within millimeter-diameter tubing and simultaneously permit the transit of magnetic beads across the interfaces. In this report, we identify the physical parameters of the materials that maximize fluid stability and bead transport and minimize solution carryover. We found that fluid stability is maximized with ≤0.8 mm i.d. tubing, valve fluids of similar density to the adjacent solutions, and tubing with ≤20 dyn/cm surface energy. Maximizing bead transport was achieved using ≥2.4 mm i.d. tubing, mineral oil valve fluid, and a mass of 1-3 mg beads. The amount of solution carryover across a surface tension valve was minimized using ≤0.2 mg of beads, tubing with ≤20 dyn/cm surface energy, and air separators. The most favorable parameter space for valve stability and bead transport was identified by combining our experimental results into a single plot using two dimensionless numbers. A strategy is presented for developing additional self-contained assays based on magnetic beads and surface tension valves for low-resource diagnostic applications. PMID:24403996

  14. Numerical Error Estimation with UQ

    NASA Astrophysics Data System (ADS)

    Ackmann, Jan; Korn, Peter; Marotzke, Jochem

    2014-05-01

    Ocean models are still in need of means to quantify model errors, which are inevitably made when running numerical experiments. The total model error can formally be decomposed into two parts, the formulation error and the discretization error. The formulation error arises from the continuous formulation of the model not fully describing the studied physical process. The discretization error arises from having to solve a discretized model instead of the continuously formulated model. Our work on error estimation is concerned with the discretization error. Given a solution of a discretized model, our general problem statement is to find a way to quantify the uncertainties due to discretization in physical quantities of interest (diagnostics), which are frequently used in Geophysical Fluid Dynamics. The approach we use to tackle this problem is called the "Goal Error Ensemble method". The basic idea of the Goal Error Ensemble method is that errors in diagnostics can be translated into a weighted sum of local model errors, which makes it conceptually based on the Dual Weighted Residual method from Computational Fluid Dynamics. In contrast to the Dual Weighted Residual method these local model errors are not considered deterministically but interpreted as local model uncertainty and described stochastically by a random process. The parameters for the random process are tuned with high-resolution near-initial model information. However, the original Goal Error Ensemble method, introduced in [1], was successfully evaluated only in the case of inviscid flows without lateral boundaries in a shallow-water framework and is hence only of limited use in a numerical ocean model. Our work consists in extending the method to bounded, viscous flows in a shallow-water framework. As our numerical model, we use the ICON-Shallow-Water model. In viscous flows our high-resolution information is dependent on the viscosity parameter, making our uncertainty measures viscosity-dependent. We will show that we can choose a sensible parameter by using the Reynolds-number as a criteria. Another topic, we will discuss is the choice of the underlying distribution of the random process. This is especially of importance in the scope of lateral boundaries. We will present resulting error estimates for different height- and velocity-based diagnostics applied to the Munk gyre experiment. References [1] F. RAUSER: Error Estimation in Geophysical Fluid Dynamics through Learning; PhD Thesis, IMPRS-ESM, Hamburg, 2010 [2] F. RAUSER, J. MAROTZKE, P. KORN: Ensemble-type numerical uncertainty quantification from single model integrations; SIAM/ASA Journal on Uncertainty Quantification, submitted

  15. Fluid overload in the ICU: evaluation and management.

    PubMed

    Claure-Del Granado, Rolando; Mehta, Ravindra L

    2016-08-02

    Fluid overload is frequently found in acute kidney injury patients in critical care units. Recent studies have shown the relationship of fluid overload with adverse outcomes; hence, manage and optimization of fluid balance becomes a central component of the management of critically ill patients. In critically ill patients, in order to restore cardiac output, systemic blood pressure and renal perfusion an adequate fluid resuscitation is essential. Achieving an appropriate level of volume management requires knowledge of the underlying pathophysiology, evaluation of volume status, and selection of appropriate solution for volume repletion, and maintenance and modulation of the tissue perfusion. Numerous recent studies have established a correlation between fluid overload and mortality in critically ill patients. Fluid overload recognition and assessment requires an accurate documentation of intakes and outputs; yet, there is a wide difference in how it is evaluated, reviewed and utilized. Accurate volume status evaluation is essential for appropriate therapy since errors of volume evaluation can result in either in lack of essential treatment or unnecessary fluid administration, and both scenarios are associated with increased mortality. There are several methods to evaluate fluid status; however, most of the tests currently used are fairly inaccurate. Diuretics, especially loop diuretics, remain a valid therapeutic alternative. Fluid overload refractory to medical therapy requires the application of extracorporeal therapies. In critically ill patients, fluid overload is related to increased mortality and also lead to several complications like pulmonary edema, cardiac failure, delayed wound healing, tissue breakdown, and impaired bowel function. Therefore, the evaluation of volume status is crucial in the early management of critically ill patients. Diuretics are frequently used as an initial therapy; however, due to their limited effectiveness the use of continuous renal replacement techniques are often required for fluid overload treatment. Successful fluid overload treatment depends on precise assessment of individual volume status, understanding the principles of fluid management with ultrafiltration, and clear treatment goals.

  16. Economic evaluation of diagnostic methods used in dentistry. A systematic review.

    PubMed

    Christell, Helena; Birch, Stephen; Horner, Keith; Lindh, Christina; Rohlin, Madeleine

    2014-11-01

    To review the literature of economic evaluations regarding diagnostic methods used in dentistry. Four databases (MEDLINE, Web of Science, The Cochrane library, the NHS Economic Evaluation Database) were searched for studies, complemented by hand search, until February 2013. Two authors independently screened all titles or abstracts and then applied inclusion and exclusion criteria to select full-text publications published in English, which reported an economic evaluation comparing at least two alternative methods. Studies of diagnostic methods were assessed by four reviewers using a protocol based on the QUADAS tool regarding diagnostic methods and a check-list for economic evaluations. The results of the data extraction were summarized in a structured table and as a narrative description. From 476 identified full-text publications, 160 were considered to be economic evaluations. Only 12 studies (7%) were on diagnostic methods, whilst 78 studies (49%) were on prevention and 70 (40%) on treatment. Among studies on diagnostic methods, there was between-study heterogeneity methodologically, regarding the diagnostic method analysed and type of economic evaluation addressed. Generally, the choice of economic evaluation method was not justified and the perspective of the study not stated. Costing of diagnostic methods varied. A small body of literature addresses economic evaluation of diagnostic methods in dentistry. Thus, there is a need for studies from various perspectives with well defined research questions and measures of the cost and effectiveness. Economic resources in healthcare are finite. For diagnostic methods, an understanding of efficacy provides only part of the information needed for evidence-based practice. This study highlighted a paucity of economic evaluations of diagnostic methods used in dentistry, indicating that much of what we practise lacks sufficient evidence.

  17. Diagnostic and prognostic value of procalcitonin for early intracranial infection after craniotomy

    PubMed Central

    Yu, Y.; Li, H.J.

    2017-01-01

    Intracranial infection is a common clinical complication after craniotomy. We aimed to explore the diagnostic and prognostic value of dynamic changing procalcitonin (PCT) in early intracranial infection after craniotomy. A prospective study was performed on 93 patients suspected of intracranial infection after craniotomy. Routine peripheral venous blood was collected on the day of admission, and C reactive protein (CRP) and PCT levels were measured. Cerebrospinal fluid (CSF) was collected for routine biochemical, PCT and culture assessment. Serum and CSF analysis continued on days 1, 2, 3, 5, 7, 9, and 11. The patients were divided into intracranial infection group and non-intracranial infection group; intracranial infection group was further divided into infection controlled group and infection uncontrolled group. Thirty-five patients were confirmed with intracranial infection after craniotomy according to the diagnostic criteria. The serum and cerebrospinal fluid PCT levels in the infected group were significantly higher than the non-infected group on day 1 (P<0.05, P<0.01). The area under curve of receiver operating characteristics was 0.803 for CSF PCT in diagnosing intracranial infection. The diagnostic sensitivity and specificity of CSF PCT was superior to other indicators. The serum and CSF PCT levels have potential value in the early diagnosis of intracranial infection after craniotomy. Since CSF PCT levels have higher sensitivity and specificity, dynamic changes in this parameter could be used for early detection of intracranial infection after craniotomy, combined with other biochemical indicators. PMID:28443989

  18. Diagnostic Accuracy of Cerebrospinal Fluid Procalcitonin in Bacterial Meningitis Patients with Empiric Antibiotic Pretreatment.

    PubMed

    Li, Wen; Sun, Xiaolong; Yuan, Fang; Gao, Qiong; Ma, Yue; Jiang, Yongli; Yang, Xiai; Yang, Fang; Ma, Lei; Jiang, Wen

    2017-04-01

    Accurate diagnosis of bacterial meningitis (BM) relies on cerebrospinal fluid (CSF) Gram staining and bacterial culture, which often present high false-negative rates because of antibiotic abuse. Thus, a novel and reliable diagnostic biomarker is required. Procalcitonin (PCT) has been well demonstrated to be specifically produced from peripheral tissues by bacterial infection, which makes it a potential diagnostic biomarker candidate. Here, we performed a prospective clinical study comprising a total of 143 patients to investigate the diagnostic value of CSF PCT, serum PCT, and other conventional biomarkers for BM. Patients were assigned to the BM ( n = 49), tuberculous meningitis (TBM) ( n = 25), viral meningitis/encephalitis (VM/E) ( n = 34), autoimmune encephalitis (AIE) ( n = 15), or noninflammatory nervous system diseases (NINSD) group ( n = 20). Empirical antibiotic pretreatment was not an exclusion criterion. Our results show that the CSF PCT level was significantly ( P < 0.01) higher in patients with BM (median, 0.22 ng/ml; range, 0.13 to 0.54 ng/ml) than in those with TBM (median, 0.12 ng/ml; range, 0.07 to 0.16 ng/ml), VM/E (median, 0.09 ng/ml; range, 0.07 to 0.11 ng/ml), AIE (median, 0.06 ng/ml; range, 0.05 to 0.10 ng/ml), or NINSD (median, 0.07 ng/ml; range, 0.06 to 0.08 ng/ml). Among the assessed biomarkers, CSF PCT exhibited the largest area under the receiver operating characteristic curve (0.881; 95% confidence interval, 0.810 to 0.932; cutoff value, 0.15 ng/ml; sensitivity, 69.39%; specificity, 91.49%). Our study sheds light upon the diagnostic dilemma of BM due to antibiotic abuse. (This study has been registered at ClinicalTrials.gov under registration no. NCT02278016.). Copyright © 2017 American Society for Microbiology.

  19. Efficacy and safety of non-suture dural closure using a novel dural substitute consisting of polyglycolic acid felt and fibrin glue to prevent cerebrospinal fluid leakage-A non-controlled, open-label, multicenter clinical trial.

    PubMed

    Terasaka, Shunsuke; Taoka, Toshiaki; Kuroda, Satoshi; Mikuni, Nobutaka; Nishi, Toru; Nakase, Hiroyuki; Fujii, Yukihiko; Hayashi, Yasuhiko; Murata, Jun-Ichi; Kikuta, Ken-Ichiro; Kuroiwa, Toshihiko; Shimokawa, Sachie; Houkin, Kiyohiro

    2017-05-01

    The objective of this study is to evaluate the efficacy and safety of non-suture dural closure using a novel dural substitute (GM111) consisting of polyglycolic acid felt with a fibrin-glue-coated area commensurate in size with the dural defect. This was a non-controlled, open-label, multicenter clinical trial. The efficacy evaluation endpoints were (1) GM111's intra-operative capability to close dural defects and (2) prevention of cerebrospinal fluid (CSF) leakage and subcutaneous CSF retention throughout the postoperative period (evaluated by diagnostic imaging). Patients meeting the following three preoperative and two intra-operative selection criteria were enrolled: (1) between 12 and <75 years of age; (2) the dura is surmised to be defective and in need of reconstruction; (3) informed written consent was obtained from the patient; (4) the surgical wound is class 1; and (5) the size of duraplasty is ≥0.2 cm 2 to <100 cm 2 . Sixty patients were enrolled. The craniotomy site was supratentorial in 77.2%, infratentorial in 12.3% and sellar in 10.5%. The GM111 prosthesis size ranged from 0.24 to 42 cm 2 . To evaluate the efficacy, intra-operative closure was confirmed by Valsalva's maneuver, water infusion, etc., in all patients. CSF leakage and subcutaneous CSF retention throughout the postoperative period were found in four patients. Adverse events for which a causal relationship with GM111 could not be ruled out occurred in 8.8% of the patients. There were no instances of postoperative infection due to GM111. GM111 showed good closure capability and safety when used for non-suture dural closure.

  20. Neuronuclear imaging in the evaluation of dementia and mild decline in cognition.

    PubMed

    Torosyan, Nare; Silverman, Daniel H S

    2012-11-01

    Recently, the National Institute on Aging and the Alzheimer's Association identified specific structural and functional neuroimaging findings as valuable markers of biological processes occurring in the human brain, especially processes that herald impending dementia caused by Alzheimer's disease (AD) in its prodromal form. In particular, the imaging modalities of magnetic resonance imaging and positron emission tomography (PET) were singled out, along with certain biomarkers in cerebrospinal fluid, to serve this purpose. We review the clinical tests available for neuropsychologic evaluation and in cases when the differential diagnosis for the causes of cognitive impairment is difficult to make, we consider biomarkers, beginning with cerebrospinal fluid, for assessment of cognitive decline. For more direct information on dementia-related pathologic changes in brain tissue, structural features observed in magnetic resonance imaging scans are regarded. We next discuss the use of single-photon emission computed tomography for evaluating functional changes. Then, pertinent to the recent National Institute on Aging and the Alzheimer's Association's consensus statement on the diagnosis of prodromal AD, we focus on assessing the cerebral metabolic changes associated with neurodegenerative diseases that are identified with fluorodeoxyglucose PET, as well as consider the most appropriate roles for amyloid imaging based on recent studies examining the use of PET with tracers having higher retention in brain tissue-harboring plaques composed of insoluble beta-amyloid. We also consider the leading causes for the current underuse of neuronuclear imaging in evaluating patients with cognitive problems, along with strategies for combating them. Finally, we suggest an overall diagnostic algorithm to guide optimal use of all the neuroimaging tools in assessing patients with cognitive decline. Copyright © 2012 Elsevier Inc. All rights reserved.

  1. Thermo-Physical Properties of Intermediate Temperature Heat Pipe Fluids

    NASA Technical Reports Server (NTRS)

    Beach, Duane E. (Technical Monitor); Devarakonda, Angirasa; Anderson, William G.

    2005-01-01

    Heat pipes are among the most promising technologies for space radiator systems. The paper reports further evaluation of potential heat pipe fluids in the intermediate temperature range of 400 to 700 K in continuation of two recent reports. More thermo-physical property data are examined. Organic, inorganic, and elemental substances are considered. The evaluation of surface tension and other fluid properties are examined. Halides are evaluated as potential heat pipe fluids. Reliable data are not available for all fluids and further database development is necessary. Many of the fluids considered are promising candidates as heat pipe fluids. Water is promising as a heat pipe fluid up to 500 to 550 K. Life test data for thermo-chemical compatibility are almost non-existent.

  2. Thermo-Physical Properties of Intermediate Temperature Heat Pipe Fluids

    NASA Technical Reports Server (NTRS)

    Devarakonda, Angirasa; Anderson, William G.

    2004-01-01

    Heat pipes are among the most promising technologies for space radiator systems. The paper reports further evaluation of potential heat pipe fluids in the intermediate temperature range of 400 to 700 K in continuation of two recent reports. More thermo-physical property data are examined. Organic, inorganic and elemental substances are considered. The evaluation of surface tension and other fluid properties are examined. Halides are evaluated as potential heat pipe fluids. Reliable data are not available for all fluids and further database development in necessary. Many of the fluids considered are promising candidates as heat pipe fluids. Water is promising as a heat pipe fluid up to 500-550 K. Life test data for thermo-chemical compatibility are almost non-existent.

  3. Magnetic Fluid Friction and Wear Behavior

    NASA Technical Reports Server (NTRS)

    Keith, Theo G., Jr.

    1998-01-01

    The friction and wear properties of two groups of magnetic fluids, one developed at NASA Lewis Research Center and a commercial fluid, were evaluated for boundary lubrication. Friction and wear measurements were made using a pin-on-disk apparatus. Three different ball materials were evaluated, (1) 440C, (2) Al2O3, and (3) Si3N4 against 440C disks. The first class of magnetic fluids have a low vapor pressure hydrocarbon base oil and are suitable for space application. Four variations of this fluid were evaluated: (1) the base oil, (2) base oil with anti-wear additives, (3) a 100 Gauss strength magnetic fluid, and (4) a 400 gauss magnetic fluid. The commercial fluid base oil and four different magnetic particle concentration levels have been evaluated. A space qualified fluorinated lubricant was tested for base line comparison. Hardness, optical microscopy, surface profilometry, and surface analysis were used to characterize the test specimens. Friction was unaffected by the concentration of magnetic particles. Wear rates for magnetic fluids were slightly higher than the base oil. The low vapor pressure magnetic fluid has better wear characteristics than the space qualified fluorinated lubricant.

  4. Combination of long noncoding RNA MALAT1 and carcinoembryonic antigen for the diagnosis of malignant pleural effusion caused by lung cancer.

    PubMed

    Wang, Wan-Wei; Zhou, Xi-Lei; Song, Ying-Jian; Yu, Chang-Hua; Zhu, Wei-Guo; Tong, Yu-Suo

    2018-01-01

    Long noncoding RNAs (lncRNAs) are present in body fluids, but their potential as tumor biomarkers has never been investigated in malignant pleural effusion (MPE) caused by lung cancer. The aim of this study was to assess the clinical significance of lncRNAs in pleural effusion, which could potentially serve as diagnostic and predictive markers for lung cancer-associated MPE (LC-MPE). RNAs from pleural effusion were extracted in 217 cases of LC-MPE and 132 cases of benign pleural effusion (BPE). Thirty-one lung cancer-associated lncRNAs were measured using quantitative real-time polymerase chain reaction (qRT-PCR). The level of carcinoembryonic antigen (CEA) was also determined. The receiver operating characteristic (ROC) curves and the area under the ROC curve (AUC) were established to evaluate the sensitivity and specificity of the identified lncRNAs and other biomarkers. The correlations between baseline pleural effusion lncRNAs expression and response to chemotherapy were also analyzed. Three lncRNAs ( MALAT1 , H19 , and CUDR ) were found to have potential as diagnostic markers in LC-MPE. The AUCs for MALAT1 , H19 , CUDR , and CEA were 0.891, 0.783, 0.824, and 0.826, respectively. Using a logistic model, the combination of MALAT1 and CEA (AUC, 0.924) provided higher sensitivity and accuracy in predicting LC-MPE than CEA (AUC, 0.826) alone. Moreover, baseline MALAT1 expression in pleural fluid was inversely correlated with chemotherapy response in patients with LC-MPE. Pleural effusion lncRNAs were effective in differentiating LC-MPE from BPE. The combination of MALAT1 and CEA was more effective for LC-MPE diagnosis.

  5. Identification of candidate cerebrospinal fluid biomarkers in parkinsonism using quantitative proteomics.

    PubMed

    Magdalinou, N K; Noyce, A J; Pinto, R; Lindstrom, E; Holmén-Larsson, J; Holtta, M; Blennow, K; Morris, H R; Skillbäck, T; Warner, T T; Lees, A J; Pike, I; Ward, M; Zetterberg, H; Gobom, J

    2017-04-01

    Neurodegenerative parkinsonian syndromes have significant clinical and pathological overlap, making early diagnosis difficult. Cerebrospinal fluid (CSF) biomarkers may aid the differentiation of these disorders, but other than α-synuclein and neurofilament light chain protein, which have limited diagnostic power, specific protein biomarkers remain elusive. To study disease mechanisms and identify possible CSF diagnostic biomarkers through discovery proteomics, which discriminate parkinsonian syndromes from healthy controls. CSF was collected consecutively from 134 participants; Parkinson's disease (n = 26), atypical parkinsonian syndromes (n = 78, including progressive supranuclear palsy (n = 36), multiple system atrophy (n = 28), corticobasal syndrome (n = 14)), and elderly healthy controls (n = 30). Participants were divided into a discovery and a validation set for analysis. The samples were subjected to tryptic digestion, followed by liquid chromatography-mass spectrometry analysis for identification and relative quantification by isobaric labelling. Candidate protein biomarkers were identified based on the relative abundances of the identified tryptic peptides. Their predictive performance was evaluated by analysis of the validation set. 79 tryptic peptides, derived from 26 proteins were found to differ significantly between atypical parkinsonism patients and controls. They included acute phase/inflammatory markers and neuronal/synaptic markers, which were respectively increased or decreased in atypical parkinsonism, while their levels in PD subjects were intermediate between controls and atypical parkinsonism. Using an unbiased proteomic approach, proteins were identified that were able to differentiate atypical parkinsonian syndrome patients from healthy controls. Our study indicates that markers that may reflect neuronal function and/or plasticity, such as the amyloid precursor protein, and inflammatory markers may hold future promise as candidate biomarkers in parkinsonism. Copyright © 2017. Published by Elsevier Ltd.

  6. Varicella zoster virus myelitis in two elderly patients: diagnostic value of nested polymerase chain reaction assay and antibody index for cerebrospinal fluid specimens.

    PubMed

    Takahashi, Teruyuki; Tamura, Masato; Miki, Kenji; Yamaguchi, Mai; Kanno, Akira; Nunomura, Satoshi; Ra, Chisei; Tamiya, Takashi; Kamei, Satoshi; Takasu, Toshiaki

    2013-01-01

    Myelitis is one of the rarest neurological complications of the varicella zoster virus (VZV) infection. Focal muscle weakness with or without sensory disturbance occurs in approximately 5% of the cases after acute VZV infection, with complete recovery in 50-70%. This report describes two rare cases of elderly patients with VZV myelitis secondary to dermatomal zoster rash. Patient 1 was a 79-year-old woman who developed paraplegia, numbness and decreased sensation in the left arm and below thoracic (Th)-10 after sacral zoster. Spinal cord MRI showed a high-signal-intensity lesion at the cervical spinal nerve 2 on a T2-weighted image. Patient 2 was a 73-year-old man who developed right flaccid leg weakness and urinary retention after right dorsal Th 5-8 zoster. Spinal cord MRI showed a high-signal-intensity lesion at Th 3-4 on a T2-weighted image. In both cases, although the conventional single polymerase chain reaction (PCR) assays all showed negative results, the original nested PCR assay detected VZV DNA in the cerebrospinal fluid (CSF) specimen collected on admission. In addition, the anti-VZV IgG antibody by enzyme immunoassay and antibody index were elevated in the CSF specimens during the clinical courses of both patients. On the basis of these findings, both patients were diagnosed with VZV myelitis and were treated with high-dose acyclovir and corticosteroid. This combined treatment was appropriate and effective for the improvement of their functional outcomes. The detection of VZV DNA in CSF by nested PCR assay and the evaluation of the antibody index to VZV had significant diagnostic value.

  7. Meningitis in adult patients with a negative direct cerebrospinal fluid examination: value of cytochemical markers for differential diagnosis

    PubMed Central

    2011-01-01

    Introduction The objective of this study was to determine the ability of various parameters commonly used for the diagnosis of acute meningitis to differentiate between bacterial and viral meningitis, in adult patients with a negative direct cerebrospinal fluid (CSF) examination. Methods This was a prospective study, started in 1997, including all patients admitted to the emergency unit with acute meningitis and a negative direct CSF examination. Serum and CSF samples were taken immediately on admission. The patients were divided into two groups according to the type of meningitis: bacterial (BM; group I) or viral (VM; group II). The CSF parameters investigated were cytology, protein, glucose, and lactate; the serum parameters evaluated were C-reactive protein and procalcitonin. CSF/serum glucose and lactate ratios were also assessed. Results Of the 254 patients with meningitis with a negative direct CSF examination, 35 had BM and 181, VM. The most highly discriminative parameters for the differential diagnosis of BM proved to be CSF lactate, with a sensitivity of 94%, a specificity of 92%, a negative predictive value of 99%, a positive predictive value of 82% at a diagnostic cut-off level of 3.8 mmol/L (area under the curve (AUC), 0.96; 95% confidence interval (CI), 0.95 to 1), and serum procalcitonin, with a sensitivity of 95%, a specificity of 100%, a negative predictive value of 100%, and a positive predictive value of 97% at a diagnostic cut-off level of 0.28 ng/ml (AUC, 0.99; 95% CI, 0.99 to 1). Conclusions Serum procalcitonin and CSF lactate concentrations appear to be the most highly discriminative parameters for the differential diagnosis of BM and VM. PMID:21645387

  8. Characteristic MRI findings in hyperglycaemia-induced seizures: diagnostic value of contrast-enhanced fluid-attenuated inversion recovery imaging.

    PubMed

    Lee, E J; Kim, K K; Lee, E K; Lee, J E

    2016-12-01

    To describe characteristic magnetic resonance imaging (MRI) abnormalities in hyperglycaemia-induced seizures, and evaluate the diagnostic value of contrast-enhanced fluid-attenuated inversion recovery (FLAIR) imaging. Possible underlying mechanisms of this condition are also discussed. Eleven patients with hyperglycaemia-induced seizures and MRI abnormalities were retrospectively studied. Clinical manifestations, laboratory findings, MRI findings, and clinical outcomes were analysed. All patients, except one, presented with focal seizures, simple or complex partial seizures, or negative motor seizures. All patients had long-standing uncontrolled diabetes mellitus. The MRI abnormalities observed acutely were focal subcortical hypointensities on T2-weighted imaging and FLAIR imaging in all patients with overlying cortical gyral T2 hyperintensities in five. Focal overlying cortical or leptomeningeal enhancement on contrast-enhanced T1-weighted imaging or contrast-enhanced FLAIR imaging was observed in all patients. Contrast-enhanced FLAIR imaging was superior to contrast-enhanced T1-weighted imaging for detecting characteristic cortical or leptomeningeal enhancement. Diffusion-weighted imaging showed mildly restricted diffusion in four of five patients with cortical gyral T2 hyperintensity. In nine patients, the lesions were localised in the parietal or parieto-occipital lobes. The other two patients showed localised precentral gyral lesions. After treatment, the neurological symptoms, including the seizures, improved in all patients. On clinical recovery, the subcortical T2 hypointensity, gyral or leptomeningeal enhancement, and overlying cortical T2 hyperintensities resolved. Recognition of these radiological abnormalities in patients with hyperglycaemia-induced seizures is important in restricting unwarranted investigations and initiating early therapy. These patients generally have a good prognosis. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  9. Analysis of some chosen elements of cerebrospinal fluid and serum in amyotrophic lateral sclerosis patients by total reflection X-ray fluorescence

    NASA Astrophysics Data System (ADS)

    Ostachowicz, B.; Lankosz, M.; Tomik, B.; Adamek, D.; Wobrauschek, P.; Streli, C.; Kregsamer, P.

    2006-11-01

    Trace elements play an important role in the human central nervous system. Significant variations of the concentration of trace elements in body fluids may occur in neurodegenerative diseases. In the present work an investigation of the elemental composition of the serum, and the cerebrospinal fluid in amyotrophic lateral sclerosis patients and a control group was performed. For the analysis of the body fluids Total reflection X-ray Fluorescence (TXRF) spectrometry was used. The samples were taken during routine diagnostic procedures. Na, Mg, Cl, K, Ca, Cu, Zn, and Br were determined in both fluids. In order to validate the results of analysis a serum standard reference material was measured. A t-test was applied to check if the mean concentrations of the elements are different for ALS and the control group. For the serum samples higher values for Br were found in the ALS group, for the cerebrospinal fluid lower values of Na, Mg and Zn as well as higher Ca values were found in the ALS group compared to the control group.

  10. Modeling electrical double-layer effects for microfluidic impedance spectroscopy from 100 kHz to 110 GHz.

    PubMed

    Little, Charles A E; Orloff, Nathan D; Hanemann, Isaac E; Long, Christian J; Bright, Victor M; Booth, James C

    2017-07-25

    Broadband microfluidic-based impedance spectroscopy can be used to characterize complex fluids, with applications in medical diagnostics and in chemical and pharmacological manufacturing. Many relevant fluids are ionic; during impedance measurements ions migrate to the electrodes, forming an electrical double-layer. Effects from the electrical double-layer dominate over, and reduce sensitivity to, the intrinsic impedance of the fluid below a characteristic frequency. Here we use calibrated measurements of saline solution in microfluidic coplanar waveguide devices at frequencies between 100 kHz and 110 GHz to directly measure the double-layer admittance for solutions of varying ionic conductivity. We successfully model the double-layer admittance using a combination of a Cole-Cole response with a constant phase element contribution. Our analysis yields a double-layer relaxation time that decreases linearly with solution conductivity, and allows for double-layer effects to be separated from the intrinsic fluid response and quantified for a wide range of conducting fluids.

  11. Voltage-Gated Potassium Channel Autoimmunity Mimicking Creutzfeldt-Jakob Disease

    PubMed Central

    Geschwind, Michael D.; Tan, K. Meng; Lennon, Vanda A.; Barajas, Ramon F.; Haman, Aissa; Klein, Christopher J.; Josephson, S. Andrew; Pittock, Sean J.

    2009-01-01

    Background Rapidly progressive dementia has a variety of causes, including Creutzfeldt-Jakob disease (CJD) and neuronal voltage-gated potassium channel (VGKC) autoantibody–associated encephalopathy. Objective To describe patients thought initially to have CJD but found subsequently to have immunotherapy-responsive VGKC autoimmunity. Design Observational, prospective case series. Setting Department of Neurology, Mayo Clinic, and the Memory and Aging Center, University of California, San Francisco. Patients A clinical serologic cohort of 15 patients referred for paraneoplastic autoantibody evaluation. Seven patients were evaluated clinically by at least one of us. Clinical information for the remaining patients was obtained by physician interview or medical record review. Main Outcome Measures Clinical features, magnetic resonance imaging abnormalities, electroencephalographic patterns, cerebrospinal fluid analyses, and responses to immunomodulatory therapy. Results All the patients presented subacutely with neurologic manifestations, including rapidly progressive dementia, myoclonus, extrapyramidal dysfunction, visual hallucinations, psychiatric disturbance, and seizures; most (60%) satisfied World Health Organization diagnostic criteria for CJD. Magnetic resonance imaging abnormalities included cerebral cortical diffusion-weighted imaging hyperintensities. Electroencephalographic abnormalities included diffuse slowing, frontal intermittent rhythmic delta activity, and focal epileptogenic activity but not periodic sharp wave complexes. Cerebrospinal fluid 14-3-3 protein or neuron-specific enolase levels were elevated in 5 of 8 patients. Hyponatremia was common (60%). Neoplasia was confirmed histologically in 5 patients (33%) and was suspected in another 5. Most patients’ conditions (92%) improved after immunomodulatory therapy. Conclusions Clinical, radiologic, electrophysiologic, and laboratory findings in VGKC autoantibody–associated encephalopathy may be confused with those of CJD. Serologic evaluation for markers of neurologic autoimmunity, including VGKC autoantibodies, may be warranted in suspected CJD cases. PMID:18852349

  12. Noninvasive Thermal Evaluation of Ventriculoperitoneal Shunt Patency and Cerebrospinal Fluid Flow Using a Flow Enhancing Device.

    PubMed

    Hameed, Mustafa Q; Zurakowski, David; Proctor, Mark R; Stone, Scellig S D; Warf, Benjamin C; Smith, Edward R; Goumnerova, Liliana C; Swoboda, Marek; Anor, Tomer; Madsen, Joseph R

    2018-06-16

    While a noninvasive flow determination would be desirable in the diagnosis of cerebrospinal fluid shunt malfunction, existing studies have not yet defined a role for thermal flow detection. To evaluate a revised test protocol using a micropumper designed to transiently enhance flow during thermal testing to determine whether thermal detection of flow is associated with progression to shunt revision surgery. Eighty-two unique tests were performed in 71 shunts. The primary outcome, need for revision within 7 d of testing, was compared with results of micropumper-augmented thermal flow detection. Statistical analysis was based on blind interpretation of test results and raw temperature data recorded during testing. The test was sensitive (73%) and specific (68%) in predicting need for revision, with 5.6-fold higher probability of revision when flow was not detected. Negative predictive value in our sample was 94.2%. The probability of not requiring revision increased with increasing total temperature drop. Analysis of various possible thresholds showed that the optimal temperature cutoff may be lower than suggested by the manufacturer (0.125°C vs 0.2°C). This is the first study to report a strong association between thermal flow evaluation and a clinical impression that a shunt is not malfunctioning. The current recommended threshold may increase the false positive rate unnecessarily, and as clinicians gain experience with the method, they may find value in examining the temperature curves themselves. Multicenter studies are suggested to further define a role for this diagnostic test.

  13. Diagnostic accuracy of intracellular mycobacterium tuberculosis detection for tuberculous meningitis.

    PubMed

    Feng, Guo-dong; Shi, Ming; Ma, Lei; Chen, Ping; Wang, Bing-ju; Zhang, Min; Chang, Xiao-lin; Su, Xiu-chu; Yang, Yi-ning; Fan, Xin-hong; Dai, Wen; Liu, Ting-ting; He, Ying; Bian, Ting; Duan, Li-xin; Li, Jin-ge; Hao, Xiao-ke; Liu, Jia-yun; Xue, Xin; Song, Yun-zhang; Wu, Hai-qin; Niu, Guo-qiang; Zhang, Li; Han, Cui-juan; Lin, Hong; Lin, Zhi-hui; Liu, Jian-jun; Jian, Qian; Zhang, Jin-she; Tian, Ye; Zhou, Bai-yu; Wang, Jing; Xue, Chang-hu; Han, Xiao-fang; Wang, Jian-feng; Wang, Shou-lian; Thwaites, Guy E; Zhao, Gang

    2014-02-15

    Early diagnosis and treatment of tuberculous meningitis saves lives, but current laboratory diagnostic tests lack sensitivity. We investigated whether the detection of intracellular bacteria by a modified Ziehl-Neelsen stain and early secretory antigen target (ESAT)-6 in cerebrospinal fluid leukocytes improves tuberculous meningitis diagnosis. Cerebrospinal fluid specimens from patients with suspected tuberculous meningitis were stained by conventional Ziehl-Neelsen stain, a modified Ziehl-Neelsen stain involving cytospin slides with Triton processing, and an ESAT-6 immunocytochemical stain. Acid-fast bacteria and ESAT-6-expressing leukocytes were detected by microscopy. All tests were performed prospectively in a central laboratory by experienced technicians masked to the patients' final diagnosis. Two hundred and eighty patients with suspected tuberculous meningitis were enrolled. Thirty-seven had Mycobacterium tuberculosis cultured from cerebrospinal fluid; 40 had a microbiologically confirmed alternative diagnosis; the rest had probable or possible tuberculous meningitis according to published criteria. Against a clinical diagnostic gold standard the sensitivity of conventional Ziehl-Neelsen stain was 3.3% (95% confidence interval, 1.6-6.7%), compared with 82.9% (95% confidence interval, 77.4-87.3%) for modified Ziehl-Neelsen stain and 75.1% (95% confidence interval, 68.8-80.6%) for ESAT-6 immunostain. Intracellular bacteria were seen in 87.8% of the slides positive by the modified Ziehl-Neelsen stain. The specificity of modified Ziehl-Neelsen and ESAT-6 stain was 85.0% (95% confidence interval, 69.4-93.8%) and 90.0% (95% confidence interval, 75.4-96.7%), respectively. Enhanced bacterial detection by simple modification of the Ziehl-Neelsen stain and an ESAT-6 intracellular stain improve the laboratory diagnosis of tuberculous meningitis.

  14. Postural headache in a child with Marfan syndrome: case report and review of the literature.

    PubMed

    Rosser, Tena; Finkel, Julie; Vezina, Gilbert; Majd, Massoud

    2005-02-01

    The case of a 10-year-old female with Marfan syndrome and postural headache secondary to spontaneous intracranial hypotension is described. The patient was found to have multiple dural ectasias and a cerebrospinal fluid leak at the left cervicothoracic junction. Her presentation, diagnostic work-up, and management are reviewed, and the relevant literature is discussed. Spontaneous intracranial hypotension secondary to cerebrospinal fluid leaks from dural ectasia should be recognized as a potential complication in children with Marfan syndrome and other connective tissue diseases.

  15. Reversible grasp reflexes in normal pressure hydrocephalus.

    PubMed

    Thomas, Rhys H; Bennetto, Luke; Silva, Mark T

    2009-05-01

    We present two cases of normal pressure hydrocephalus in combination with grasp reflexes. In both cases the grasp reflexes disappeared following high volume cerebrospinal fluid removal. In one of the cases the grasp reflexes returned over a period of weeks but again resolved following definitive cerebrospinal fluid shunting surgery, and remained absent until final follow up at 9 months. We hypothesise that resolving grasp reflexes following high volume CSF removal has both diagnostic and prognostic value in normal pressure hydrocephalus, encouraging larger studies on the relevance of primitive reflexes in NPH.

  16. A short-wave infrared otoscope for middle ear disease diagnostics (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Carr, Jessica A.; Valdez, Tulio; Bruns, Oliver; Bawendi, Moungi

    2016-02-01

    Otitis media, a range of inflammatory conditions of the middle ear, is the second most common illness diagnosed in children. However, the diagnosis can be challenging, particularly in pediatric patients. Otitis media is commonly over-diagnosed and over-treated and has been identified as one of the primary factors in increased antibiotic resistance. We describe the development of a short-wave infrared (SWIR) otoscope for objective middle ear effusion diagnosis. The SWIR otoscope can unambiguously detect the presence of middle ear fluid based on its strong light absorption in the SWIR. This absorption causes a stark, visual contrast between the presence and absence of fluid behind the tympanic membrane. Additionally, when there is no middle ear fluid, the deeper tissue penetration of SWIR light allows the SWIR otoscope to better visualize middle ear anatomy through the tympanic membrane than is possible with visible light. We demonstrate that in healthy, adult human ears, SWIR otoscopy can image a range of middle ear anatomy, including landmarks of the entire ossicular chain, the promontory, the round window niche, and the chorda tympani. We suggest that SWIR otoscopy can provide valuable diagnostic information complementary to that provided by visible pneumotoscopy in the diagnosis of middle ear effusions, otitis media, and other maladies of the middle ear.

  17. BEAMing and Droplet Digital PCR Analysis of Mutant IDH1 mRNA in Glioma Patient Serum and Cerebrospinal Fluid Extracellular Vesicles

    PubMed Central

    Chen, Walter W; Balaj, Leonora; Liau, Linda M; Samuels, Michael L; Kotsopoulos, Steve K; Maguire, Casey A; LoGuidice, Lori; Soto, Horacio; Garrett, Matthew; Zhu, Lin Dan; Sivaraman, Sarada; Chen, Clark; Wong, Eric T; Carter, Bob S; Hochberg, Fred H; Breakefield, Xandra O; Skog, Johan

    2013-01-01

    Development of biofluid-based molecular diagnostic tests for cancer is an important step towards tumor characterization and real-time monitoring in a minimally invasive fashion. Extracellular vesicles (EVs) are released from tumor cells into body fluids and can provide a powerful platform for tumor biomarkers because they carry tumor proteins and nucleic acids. Detecting rare point mutations in the background of wild-type sequences in biofluids such as blood and cerebrospinal fluid (CSF) remains a major challenge. Techniques such as BEAMing (beads, emulsion, amplification, magnetics) PCR and droplet digital PCR (ddPCR) are substantially more sensitive than many other assays for mutant sequence detection. Here, we describe a novel approach that combines biofluid EV RNA and BEAMing RT-PCR (EV-BEAMing), as well droplet digital PCR to interrogate mutations from glioma tumors. EVs from CSF of patients with glioma were shown to contain mutant IDH1 transcripts, and we were able to reliably detect and quantify mutant and wild-type IDH1 RNA transcripts in CSF of patients with gliomas. EV-BEAMing and EV-ddPCR represent a valuable new strategy for cancer diagnostics, which can be applied to a variety of biofluids and neoplasms. PMID:23881452

  18. Space Laboratory on a Table Top: A Next Generative ECLSS design and diagnostic tool

    NASA Technical Reports Server (NTRS)

    Ramachandran, N.

    2005-01-01

    This paper describes the development plan for a comprehensive research and diagnostic tool for aspects of advanced life support systems in space-based laboratories. Specifically it aims to build a high fidelity tabletop model that can be used for the purpose of risk mitigation, failure mode analysis, contamination tracking, and testing reliability. We envision a comprehensive approach involving experimental work coupled with numerical simulation to develop this diagnostic tool. It envisions a 10% scale transparent model of a space platform such as the International Space Station that operates with water or a specific matched index of refraction liquid as the working fluid. This allows the scaling of a 10 ft x 10 ft x 10 ft room with air flow to 1 ft x 1 ft x 1 ft tabletop model with water/liquid flow. Dynamic similitude for this length scale dictates model velocities to be 67% of full-scale and thereby the time scale of the model to represent 15% of the full- scale system; meaning identical processes in the model are completed in 15% of the full- scale-time. The use of an index matching fluid (fluid that matches the refractive index of cast acrylic, the model material) allows making the entire model (with complex internal geometry) transparent and hence conducive to non-intrusive optical diagnostics. So using such a system one can test environment control parameters such as core flows (axial flows), cross flows (from registers and diffusers), potential problem areas such as flow short circuits, inadequate oxygen content, build up of other gases beyond desirable levels, test mixing processes within the system at local nodes or compartments and assess the overall system performance. The system allows quantitative measurements of contaminants introduced in the system and allows testing and optimizing the tracking process and removal of contaminants. The envisaged system will be modular and hence flexible for quick configuration change and subsequent testing. The data and inferences from the tests will allow for improvements in the development and design of next generation life support systems and configurations. Preliminary experimental and modeling work in this area will be presented. This involves testing of a single inlet-exit model with detailed 3-D flow visualization and quantitative diagnostics and computational modeling of the system.

  19. Development and evaluation of a Sarcocystis neurona-specific IgM capture enzyme-linked immunosorbent assay.

    PubMed

    Murphy, J E; Marsh, A E; Reed, S M; Meadows, C; Bolten, K; Saville, W J A

    2006-01-01

    Equine protozoal myeloencephalitis (EPM) is a serious neurologic disease of horses caused primarily by the protozoal parasite Sarcocystis neurona. Currently available antemortem diagnostic testing has low specificity. The hypothesis of this study was that serum and cerebrospinal fluid (CSF) of horses experimentally challenged with S neurona would have an increased S neurona-specific IgM (Sn-IgM) concentration after infection, as determined by an IgM capture enzyme linked immunoassay (ELISA). The ELISA was based on the S neurona low molecular weight protein SNUCD-1 antigen and the monoclonal antibody 2G5 labeled with horseradish peroxidase. The test was evaluated using serum and CSF from 12 horses experimentally infected with 1.5 million S neurona sporocysts and 16 horses experimentally infected with varying doses (100 to 100,000) of S neurona sporocysts, for which results of histopathologic examination of the central nervous system were available. For horses challenged with 1.5 million sporocysts, there was a significant increase in serum Sn-IgM concentrations compared with values before infection at weeks 2-6 after inoculation (P < .0001). For horses inoculated with lower doses of S neurona, there were significant increases in serum Sn-IgM concentration at various points in time after inoculation, depending on the challenge dose (P < .01). In addition, there was a significant increase between the CSF Sn-IgM concentrations before and after inoculation (P < .0001). These results support further evaluation of the assay as a diagnostic test during the acute phase of EPM.

  20. FDVIBSPC16: Sheath Flow SERS for Chemical Profiling in Urine

    PubMed Central

    Riordan, Colleen M.; Jacobs, Kevin T.; Negri, Pierre; Schultz, Zachary D.

    2016-01-01

    The molecular specificity and sensitivity of surface enhanced Raman scattering (SERS) makes it an attractive method for biomedical diagnostics. Here we present results demonstrating the utility and complications for SERS characterization in urine. The chemical fingerprint characteristic of Raman spectra suggests use as a label free diagnostic; however, the complex composition of biological fluids presents a tremendous challenge. In particular, the limited number of surface sites and competing absorption tend to mask the presence of analytes in solution, particularly when the solution contains multiple analytes. To address these problems and characterize biological fluids we have demonstrated a sheath-flow interface for SERS detection. This sheath-flow SERS interface uses hydrodynamic focusing to confine analyte molecules eluting out of a column onto a planar SERS substrate where the molecules are detected by their intrinsic SERS signal. In this report we compare direct detection of benzoylecgonine in urine using DSERS with chemical profiling by capillary zone electrophoresis and sheath-flow SERS detection. The SERS spectrum from the observed migration peaks can identify benzoylecgonine and other distinct spectra are also observed, suggesting improved chemical diagnostics in urine. With over 2000 reported compounds in urine, identification of each of the detected species is an enormous task. Nonetheless, these samples provide a benchmark to establish the potential clinical utility of sheath-flow SERS detection. PMID:27034996

  1. Laboratory diagnosis of Ebola virus disease and corresponding biosafety considerations in the China Ebola Treatment Center.

    PubMed

    Huang, Qing; Fu, Wei-Ling; You, Jian-Ping; Mao, Qing

    2016-10-01

    Ebola virus disease (EVD), caused by Ebola virus (EBOV), is a potent acute infectious disease with a high case-fatality rate. Etiological and serological EBOV detection methods, including techniques that involve the detection of the viral genome, virus-specific antigens and anti-virus antibodies, are standard laboratory diagnostic tests that facilitate confirmation or exclusion of EBOV infection. In addition, routine blood tests, liver and kidney function tests, electrolytes and coagulation tests and other diagnostic examinations are important for the clinical diagnosis and treatment of EVD. Because of the viral load in body fluids and secretions from EVD patients, all body fluids are highly contagious. As a result, biosafety control measures during the collection, transport and testing of clinical specimens obtained from individuals scheduled to undergo EBOV infection testing (including suspected, probable and confirmed cases) are crucial. This report has been generated following extensive work experience in the China Ebola Treatment Center (ETC) in Liberia and incorporates important information pertaining to relevant diagnostic standards, clinical significance, operational procedures, safety controls and other issues related to laboratory testing of EVD. Relevant opinions and suggestions are presented in this report to provide contextual awareness associated with the development of standards and/or guidelines related to EVD laboratory testing.

  2. Mitigation of biofouling using coatings: Year 2. Quarterly progress report No. 1. Calspan report 6782-M-5

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meyer, A.E.; King, R.W.

    1982-01-15

    Objectives of this project are to evaluate benefits associated with control of the surface energetic properties of materials used in heat exchangers; and to identify preferred ranges of these surface conditions that minimize deposits of biological fouling known to deteriorate heat exchange efficiencies in seawater, brackish water, and freshwater systems. The technical approach employed uses special diagnostic plates in novel flow cells where fluid flow conditions can be well-controlled, modifying the surface chemistry and surface energy of the plates with very thin coatings and examining the earliest events of biofouling caused by macromolecules and microbial organisms. For the present phasemore » of the project (Year 2), attention will be focussed on biofouling in a freshwater/brackish water system.« less

  3. Fluorescent fiber diagnostics

    DOEpatents

    Toeppen, John S.

    1994-10-04

    A fluorescent fiber (13) having a doped core (16) is pumped (11) by light (18) of a relatively short wavelength to produce fluorescence at a longer wavelength that is detected by detector (24). The level of fluorescence is monitored (26) and evaluated to provide information as to the excitation of the fiber (13) or the environment thereof. In particular, the level of intensity of the detected fluorescence may be used to measure the intensity of a light beam (18) passing axially through an optical fiber system (12) (FIG. 1 ), or the intensity of a light beam (46) passing radially through a fluorescent fiber (13) (FIG. 2 ), or the level of a fluid (32) in a tank (31) (FIG. 3 ), or a scintillation event (37) in a fluorescent fiber (13) pumped to produce amplification of the scintillation event (FIG. 4 ).

  4. Fluorescent fiber diagnostics

    DOEpatents

    Toeppen, John S.

    1994-01-01

    A fluorescent fiber (13) having a doped core (16) is pumped (11) by light (18) of a relatively short wavelength to produce fluorescence at a longer wavelength that is detected by detector (24). The level of fluorescence is monitored (26) and evaluated to provide information as to the excitation of the fiber (13) or the environment thereof. In particular, the level of intensity of the detected fluorescence may be used to measure the intensity of a light beam (18) passing axially through an optical fiber system (12) (FIG. 1 ), or the intensity of a light beam (46) passing radially through a fluorescent fiber (13) (FIG. 2 ), or the level of a fluid (32) in a tank (31) (FIG. 3 ), or a scintillation event (37) in a fluorescent fiber (13) pumped to produce amplification of the scintillation event (FIG. 4 ).

  5. A FLUID SORBENT RECYCLING DEVICE FOR INDUSTRIAL FLUID USERS

    EPA Science Inventory

    A roller compression Extractor® that extracts fluids from reusable sorbent pads was evaluated as a method of waste reduction. The extraction device, evaluated for industrial fluid users in New Jersey, was found to be effective in recycling unpleated sorbent pads, especially ...

  6. Intraocular cysts of toxoplasma gondii in patients with necrotizing retinitis following periocular/intraocular triamcinolone injection.

    PubMed

    Nijhawan, Raje; Bansal, Reema; Gupta, Nalini; Beke, Nikhil; Kulkarni, Pandurang; Gupta, Amod

    2013-10-01

    To report the detection of Toxoplasma gondii cysts in intraocular aspirates of patients with necrotizing retinitis following periocular/intraocular corticosteroid injection. Case report. Two patients (2 eyes) with widespread necrotizing retinitis in a steroid-exposed eye posed a diagnostic challenge and underwent pars plana vitrectomy (PPV). Intraocular samples (vitreous fluid, retinal tissue, and subretinal aspirate in case 1, and vitreous fluid in case 2) were subjected to cytological examination. The subretinal aspirate (case 1) revealed encysted bradyzoites of Toxoplasma gondii. Vitreous fluid (case 2) tested positive for anti-toxoplasma antibodies and the smear showed encysted forms of Toxoplasma gondii on cytology. CONCLUSION. Toxoplasma gondii cysts were detected in eyes with necrotizing retinitis that developed secondary to injudicious use of corticosteroids.

  7. Microscopic FTIR studies of lung cancer cells in pleural fluid.

    PubMed

    Wang, H P; Wang, H C; Huang, Y J

    1997-10-01

    Structural changes associated with lung cancer and tuberculous cells in pleural fluid were studied by microscopic FTIR spectroscopy. Infrared spectra demonstrate significant spectral differences between normal, lung cancer and tuberculous cells. The ratio of the peak intensities of the 1030 and 1080 cm-1 bands (originated mainly in glycogen and phosphodiester groups of nucleic acids) differs greatly between normal and lung cancer samples. Such findings prompt the consideration that recording infrared spectra from lung cancer and tuberculous cells may be of diagnostic value. Since measurements of IR spectra of lung cancer cells in the pleural fluid can be a very rapid inexpensive process, our finding warrant exploration of this possibility in the investigation of the mechanism whereby the environmental pollution related cancers develop.

  8. Refractive index and solubility control of para-cymene solutions for index-matched fluid-structure interaction studies

    NASA Astrophysics Data System (ADS)

    Fort, Charles; Fu, Christopher D.; Weichselbaum, Noah A.; Bardet, Philippe M.

    2015-12-01

    To deploy optical diagnostics such as particle image velocimetry or planar laser-induced fluorescence (PLIF) in complex geometries, it is beneficial to use index-matched facilities. A binary mixture of para-cymene and cinnamaldehyde provides a viable option for matching the refractive index of acrylic, a common material for scaled models and test sections. This fluid is particularly appropriate for large-scale facilities and when a low-density and low-viscosity fluid is sought, such as in fluid-structure interaction studies. This binary solution has relatively low kinematic viscosity and density; its use enables the experimentalist to select operating temperature and to increase fluorescence signal in PLIF experiments. Measurements of spectral and temperature dependence of refractive index, density, and kinematic viscosity are reported. The effect of the binary mixture on solubility control of Rhodamine 6G is also characterized.

  9. The management of pancreatic trauma in the modern era.

    PubMed

    Subramanian, Anuradha; Dente, Christopher J; Feliciano, David V

    2007-12-01

    Pancreatic trauma presents challenging diagnostic and therapeutic dilemmas to trauma surgeons. Injuries to the pancreas have been associated with reported morbidity rates approaching 45%. If treatment is delayed, these rates may increase to 60%. The integrity of the main pancreatic duct is the most important determinant of outcome after injury to the pancreas. Undiagnosed ductal disruptions produce secondary infections, fistulas, fluid collections, and prolonged stays in the intensive care unit and hospital. This article analyzes the epidemiology, diagnostic approaches, options for nonoperative and operative management, and outcome after blunt and penetrating pancreatic trauma.

  10. Computational circular dichroism estimation for point-of-care diagnostics via vortex half-wave retarders

    NASA Astrophysics Data System (ADS)

    Haider, Shahid A.; Tran, Megan Y.; Wong, Alexander

    2018-02-01

    Observing the circular dichroism (CD) caused by organic molecules in biological fluids can provide powerful indicators of patient health and provide diagnostic clues for treatment. Methods for this kind of analysis involve tabletop devices that weigh tens of kilograms with costs on the order of tens of thousands of dollars, making them prohibitive in point-of-care diagnostic applications. In an e ort to reduce the size, cost, and complexity of CD estimation systems for point-of-care diagnostics, we propose a novel method for CD estimation that leverages a vortex half-wave retarder in between two linear polarizers and a two-dimensional photodetector array to provide an overall complexity reduction in the system. This enables the measurement of polarization variations across multiple polarizations after they interact with a biological sample, simultaneously, without the need for mechanical actuation. We further discuss design considerations of this methodology in the context of practical applications to point-of-care diagnostics.

  11. Point-of-service, quantitative analysis of ascorbic acid in aqueous humor for evaluating anterior globe integrity

    NASA Astrophysics Data System (ADS)

    Gartia, Manas R.; Misra, Santosh K.; Ye, Mao; Schwartz-Duval, Aaron; Plucinski, Lisa; Zhou, Xiangfei; Kellner, David; Labriola, Leanne T.; Pan, Dipanjan

    2015-11-01

    Limited training, high cost, and low equipment mobility leads to inaccuracies in decision making and is concerning with serious ocular injuries such as suspected ruptured globe or post-operative infections. Here, we present a novel point-of-service (POS) quantitative ascorbic acid (AA) assay with use of the OcuCheck Biosensor. The present work describes the development and clinical testing of the paper-based biosensor that measures the changes in electrical resistance of the enzyme-plated interdigitated electrodes to quantify the level of AA present in ocular fluid. We have demonstrated the proof-of-concept of the biosensor testing 16 clinical samples collected from aqueous humor of patients undergoing therapeutic anterior chamber paracentesis. Comparing with gold standard colorimetric assay for AA concentration, OcuCheck showed accuracy of >80%, sensitivity of >88% and specificity of >71%. At present, there are no FDA-approved POS tests that can directly measures AA concentration levels in ocular fluid. We envisage that the device can be realized as a handheld, battery powered instrument that will have high impact on glaucoma care and point-of-care diagnostics of penetrating ocular globe injuries.

  12. Cerebrospinal Fluid Cytokine Expression Profile in Multiple Sclerosis and Chronic Inflammatory Demyelinating Polyneuropathy.

    PubMed

    Bonin, Serena; Zanotta, Nunzia; Sartori, Arianna; Bratina, Alessio; Manganotti, Paolo; Trevisan, Giusto; Comar, Manola

    2018-02-01

    Cerebrospinal fluid (CSF) analysis in patients with particular neurologic disorders is a powerful tool to evaluate specific central nervous system inflammatory markers for diagnostic needs, because CSF represents the specific immune micro-environment to the central nervous system. CSF samples from 49 patients with multiple sclerosis (MS), chronic inflammatory demyelinating polyneuropathy (CIDP), and non-inflammatory neurologic disorders (NIND) as controls were submitted to protein expression profiles of 47 inflammatory biomarkers by multiplex Luminex bead assay to investigate possible differences in the inflammatory process for MS and CIDP. Our results showed differences in CSF cytokine levels in MS and CIDP; in particular, IL12 (p40) was significantly highly expressed in MS in comparison with CIDP and NIND, while SDF-1α and SCGF-β were significantly highly expressed in CIDP cohort when compared to MS and NIND. IL-9, IL-13, and IL-17 had higher expression levels in NIND if compared with the other groups. Our study showed that, despite some common pathogenic mechanisms, central and peripheral nervous system demyelinating diseases, such as MS and CIDP, differ in some specific inflammatory soluble proteins in CSF, underlining differences in the immune response involved in those autoimmune diseases.

  13. Correlation between osteoarthritic changes in the stifle joint in dogs and the results of orthopedic, radiographic, ultrasonographic and arthroscopic examinations.

    PubMed

    Ramírez-Flores, Gabriel Ignacio; Del Angel-Caraza, Javier; Quijano-Hernández, Israel Alejandro; Hulse, Don A; Beale, Brian S; Victoria-Mora, José Mauro

    2017-06-01

    Osteoarthritis (OA) is a chronic, degenerative disease affecting the articular cartilage and subchondral bone that causes pain and inhibits movement. The stifle's joint fibrous capsule contains the synovial membrane, which produces cartilage nutrients. A ruptured cranial cruciate ligament injures the joint and produces OA. Osteoarthritis diagnosis starts with clinical radiographic and ultrasonographic tests, although the latter is not used very much in dog and cat clinics for this purpose. The objective of this study was to establish the correlation among the results of orthopedic, radiographic, ultrasonographic examinations and structural anatomical changes revealed by arthroscopic evaluation to diagnose stifle joint OA and determine risk factors in the dogs affected. Of 44 clinical cases of OA included in the study, 88.64% had ruptured of cranial cruciate ligaments. The correlation between synovial fluid effusion and osteophytosis was of 0.84. It was concluded that there is good diagnostic agreement between synovial fluid effusion and osteophytosis when dealing with stifle joint OA. Risk factors for dogs regarding the development of stifle joint OA included: ruptured cranial cruciate ligaments or patella luxation, female dogs and weight over 10 kg.

  14. Utility of galactomannan antigen detection in bronchoalveolar lavage fluid in immunocompromised patients.

    PubMed

    Brownback, Kyle R; Pitts, Lucas R; Simpson, Steven Q

    2013-09-01

    Diagnosis of invasive pulmonary aspergillosis (IPA) is a challenging process in immunocompromised patients. Galactomannan (GM) antigen detection in bronchoalveolar lavage (BAL) fluid is a method to detect IPA with improved sensitivity over conventional studies. We sought to determine the diagnostic yield of BAL GM assay in a diverse population of immunocompromised patients. A retrospective review of 150 fiberoptic bronchoscopy (FOB) with BAL for newly diagnosed pulmonary infiltrate in immunocompromised patients was performed. Patient information, procedural details and laboratory studies were collected. BAL and serum samples were evaluated for GM using enzyme-linked immunoassay. Of 150 separate FOB with BAL, BAL GM was obtained in 143 samples. There were 31 positive BAL GM assays. In those 31 positive tests, 13 were confirmed as IPA, giving a positive predictive value of 41.9%. There was one false negative BAL GM. Of the 18 false positive BAL GM, 4 were receiving piperacillin-tazobactam and 11 were receiving an alternative beta-lactam antibiotic. BAL GM assay shows excellent sensitivity for diagnosing IPA. There was a significant number of false positive BAL GM assays and several of those patients were receiving beta-lactam antibiotics at the time of bronchoscopy. © 2013 Blackwell Verlag GmbH.

  15. Cerebrospinal fluid lactate level as a diagnostic biomarker for bacterial meningitis in children

    PubMed Central

    2014-01-01

    Background Cerebrospinal fluid (CSF) lactate is a potential biomarker for bacterial meningitis in children. To this end, we performed a single-center retrospective cohort study of children from Sao Paulo, Brazil, with CSF pleocytosis to evaluate the ability of CSF lactate to distinguish between children with bacterial and aseptic meningitis. We determined the optimum cutoff point for CSF lactate using receiver-operator curve (ROC) analysis. Findings We identified 451 children of whom 40 (9%) had bacterial meningitis. Children with bacterial meningitis had a higher median CSF lactate level [9.6 mmol/l, interquartile range (IQR) 3.2-38.5 mmol/l bacterial meningitis vs. 2.0 mmol/l, IQR 1.2-2.8 mmol/l aseptic meningitis]. A CSF lactate cutoff point of 3.0 mmol/l had a sensitivity of 95% [95% confidence interval (CI) 83-99%), specificity of 94% (95% CI 90-96%) and negative predictive value of 99.3% (95% CI 97.7-99.9%) for bacterial meningitis. Conclusions In combination with a validated meningitis clinical prediction rule, the CSF lactate level can be used to distinguish between bacterial and aseptic meningitis in children with CSF pleocytosis. PMID:24576334

  16. Cerebrospinal fluid lactate level as a diagnostic biomarker for bacterial meningitis in children.

    PubMed

    Mekitarian Filho, Eduardo; Horita, Sérgio Massaru; Gilio, Alfredo Elias; Nigrovic, Lise E

    2014-02-27

    Cerebrospinal fluid (CSF) lactate is a potential biomarker for bacterial meningitis in children. To this end, we performed a single-center retrospective cohort study of children from Sao Paulo, Brazil, with CSF pleocytosis to evaluate the ability of CSF lactate to distinguish between children with bacterial and aseptic meningitis. We determined the optimum cutoff point for CSF lactate using receiver-operator curve (ROC) analysis. We identified 451 children of whom 40 (9%) had bacterial meningitis. Children with bacterial meningitis had a higher median CSF lactate level [9.6 mmol/l, interquartile range (IQR) 3.2-38.5 mmol/l bacterial meningitis vs. 2.0 mmol/l, IQR 1.2-2.8 mmol/l aseptic meningitis]. A CSF lactate cutoff point of 3.0 mmol/l had a sensitivity of 95% [95% confidence interval (CI) 83-99%), specificity of 94% (95% CI 90-96%) and negative predictive value of 99.3% (95% CI 97.7-99.9%) for bacterial meningitis. In combination with a validated meningitis clinical prediction rule, the CSF lactate level can be used to distinguish between bacterial and aseptic meningitis in children with CSF pleocytosis.

  17. Point-of-service, quantitative analysis of ascorbic acid in aqueous humor for evaluating anterior globe integrity.

    PubMed

    Gartia, Manas R; Misra, Santosh K; Ye, Mao; Schwartz-Duval, Aaron; Plucinski, Lisa; Zhou, Xiangfei; Kellner, David; Labriola, Leanne T; Pan, Dipanjan

    2015-11-03

    Limited training, high cost, and low equipment mobility leads to inaccuracies in decision making and is concerning with serious ocular injuries such as suspected ruptured globe or post-operative infections. Here, we present a novel point-of-service (POS) quantitative ascorbic acid (AA) assay with use of the OcuCheck Biosensor. The present work describes the development and clinical testing of the paper-based biosensor that measures the changes in electrical resistance of the enzyme-plated interdigitated electrodes to quantify the level of AA present in ocular fluid. We have demonstrated the proof-of-concept of the biosensor testing 16 clinical samples collected from aqueous humor of patients undergoing therapeutic anterior chamber paracentesis. Comparing with gold standard colorimetric assay for AA concentration, OcuCheck showed accuracy of >80%, sensitivity of >88% and specificity of >71%. At present, there are no FDA-approved POS tests that can directly measures AA concentration levels in ocular fluid. We envisage that the device can be realized as a handheld, battery powered instrument that will have high impact on glaucoma care and point-of-care diagnostics of penetrating ocular globe injuries.

  18. Point-of-service, quantitative analysis of ascorbic acid in aqueous humor for evaluating anterior globe integrity

    PubMed Central

    Gartia, Manas R.; Misra, Santosh K.; Ye, Mao; Schwartz-Duval, Aaron; Plucinski, Lisa; Zhou, Xiangfei; Kellner, David; Labriola, Leanne T.; Pan, Dipanjan

    2015-01-01

    Limited training, high cost, and low equipment mobility leads to inaccuracies in decision making and is concerning with serious ocular injuries such as suspected ruptured globe or post-operative infections. Here, we present a novel point-of-service (POS) quantitative ascorbic acid (AA) assay with use of the OcuCheck Biosensor. The present work describes the development and clinical testing of the paper-based biosensor that measures the changes in electrical resistance of the enzyme-plated interdigitated electrodes to quantify the level of AA present in ocular fluid. We have demonstrated the proof-of-concept of the biosensor testing 16 clinical samples collected from aqueous humor of patients undergoing therapeutic anterior chamber paracentesis. Comparing with gold standard colorimetric assay for AA concentration, OcuCheck showed accuracy of >80%, sensitivity of >88% and specificity of >71%. At present, there are no FDA-approved POS tests that can directly measures AA concentration levels in ocular fluid. We envisage that the device can be realized as a handheld, battery powered instrument that will have high impact on glaucoma care and point-of-care diagnostics of penetrating ocular globe injuries. PMID:26525715

  19. [Generalized anxiety disorder, now and the future: a perspective to the DSM-5].

    PubMed

    Otsubo, Tempei

    2012-01-01

    Generalized, persistent, and free-floating anxiety was first described by Freud in 1894. The diagnostic term generalized anxiety disorder (GAD) was not in classification systems until the publication of the diagnostic and statistical manual for mental disorders, third edition (DSM-III) in 1980. Initially considered as a residual category to be used when no other diagnosis could be made, it is not accepted that GAD represents a distinct diagnostic category yet. Since 1980, revisions to the diagnostic criteria for GAD in the DSM-III-R, DSM-IV and DSM-5 classifications have slightly redefined this disorder. The classification is fluid. The duration criterion has increased to 6 months in DSM-IV, but decreased to 3 months in DSM-5. This article reviews the development of diagnostic criteria for defining GAD from Freud to DSM-5 and compares the DSM-5 criterion with DSM-IV and the tenth revision of the International Classification of Disease. The impact of the changes in diagnostic criteria on research into GAD, and on diagnosis, differential diagnosis, will be discussed.

  20. Human hydatid disease: evaluation of an ELISA for diagnosis, population screening and monitoring of control programmes.

    PubMed

    Biffin, A H; Jones, M A; Palmer, S R

    1993-07-01

    The routine use of ELISA and complement fixation tests in the diagnosis of suspected clinical cases of hydatid disease was evaluated. In the ELISA test, dialysed and filtered sheep cyst fluid was used as antigen and two positive cut-off points--+3SD and +2SD of the mean absorbance values of the control sera--were evaluated. The predictive values of ELISA tests were 82% and 90% for positive tests, and 86% and 82% for negative tests, respectively with the two cut-off points. In a population survey of blood donors and veterinary workers in Powys, 4% and 8%, respectively, had ELISA values above the lower cut-off point. However, it would not be appropriate to use the same test for diagnostic population screening in Wales since the predictive value of the test is likely to be very low in this setting. Serological surveys with the ELISA may be of use in monitoring the progress of the South Powys Hydatid Control Programme. The use of cumulative percentages was found to be a useful method of comparing whole distributions of results in different populations.

  1. Neuroactive steroid levels in plasma and cerebrospinal fluid of male multiple sclerosis patients.

    PubMed

    Caruso, Donatella; Melis, Marta; Fenu, Giuseppe; Giatti, Silvia; Romano, Simone; Grimoldi, Maria; Crippa, Donatella; Marrosu, Maria Giovanna; Cavaletti, Guido; Melcangi, Roberto Cosimo

    2014-08-01

    Neuroactive steroid family includes molecules synthesized in peripheral glands (i.e., hormonal steroids) and directly in the nervous system (i.e., neurosteroids) which are key regulators of the nervous function. As already reported in clinical and experimental studies, neurodegenerative diseases affect the levels of neuroactive steroids. However, a careful analysis comparing the levels of these molecules in cerebrospinal fluid (CSF) and in plasma of multiple sclerosis (MS) patients is still missing. To this aim, the levels of neuroactive steroids were evaluated by liquid chromatography-tandem mass spectrometry in CSF and plasma of male adults affected by Relapsing-Remitting MS and compared with those collected in control patients. An increase in pregnenolone and isopregnanolone levels associated with a decrease in progesterone metabolites, dihydroprogesterone, and tetrahydroprogesterone was observed in CSF of MS patients. Moreover, an increase of 5α-androstane-3α,17β-diol and of 17β-estradiol levels associated with a decrease of dihydrotestosterone also occurred. In plasma, an increase in pregnenolone, progesterone, and dihydrotestosterone and a decrease in dihydroprogesterone and tetrahydroprogesterone levels were reported. This study shows for the first time that the levels of several neuroactive steroids, and particularly those of progesterone and testosterone metabolites, are deeply affected in CSF of relapsing-remitting MS male patients. We here demonstrated that, the cerebrospinal fluid and plasma levels of several neuroactive steroids are modified in relapsing remitting multiple sclerosis male patients. Interestingly, we reported for the first time that, the levels of progesterone and testosterone metabolites are deeply affected in cerebrospinal fluid. These findings may have an important relevance in therapeutic and/or diagnostic field of multiple sclerosis. © 2014 International Society for Neurochemistry.

  2. Evaluation of a newly designed sandwich enzyme linked immunosorbent assay for the detection of hydatid antigen in serum, urine and cyst fluid for diagnosis of cystic echinococcosis

    PubMed Central

    Chaya, DR; Parija, Subhash Chandra

    2013-01-01

    Introduction: Cystic echinococcosis (CE) is a zoonotic disease of humans with variable clinical manifestations. Imaging and immunological methods are currently the mainstay of diagnosis of this disease. Although the immunological tests for detection of anti-echinococcal antibodies have several disadvantages, they are widely being used. Antigen is far more superior than antibody detection test as they can provide a specific parasitic diagnosis. Materials and Methods: A sandwich enzyme linked immunosorbent assay (ELISA) was designed using antibodies to 24 kDa urinary hydatid antigen for the detection of hydatid antigens in urine, serum and cyst fluid specimens. The performance of this novel test was compared with that of other hydatid antibody detection ELISA and enzyme immune transfer blot (EITB) using radiological and surgical confirmation as the gold standard. Results: The antigen detection ELISA showed 100% sensitivity and specificity when tested with cyst fluid. On testing urine and serum, the antigen detection ELISA was found to be more specific than antibody detection ELISA. EITB was found to be the most sensitive and specific test. Conclusions: ELISA using polyclonal antibodies against 24 kDa urinary hydatid protein was moderately sensitive to detect hydatid antigen in serum and urine. Hence polyclonal antibodies to 24 kDa urinary hydatid antigen can be used as an alternative source of antibody to detect hydatid antigen in serum, urine and cyst fluid. In the present study, EITB was found to be highly specific test for detection of hydatid antibodiesin serum. 24 kDa protein was found to be specific and of diagnostic value in CE. PMID:24470996

  3. Recommendation of Sensors for Vehicle Transmission Diagnostics

    DTIC Science & Technology

    2012-05-01

    and a pressure switch module form the Control value module. A thermistor is contained within the pressure switch module in order to monitor the sump...fluid temperature. Sensor information is provided to the TCM through various sensors such as throttle position, speed sensor, pressure switch module

  4. HYPERSENSITIVITY PNEUMONITIS AND METAL WORKING FLUIDS: THE METALWORKER'S MALAISE DIAGNOSTIC INDEX. (R825251)

    EPA Science Inventory

    The perspectives, information and conclusions conveyed in research project abstracts, progress reports, final reports, journal abstracts and journal publications convey the viewpoints of the principal investigator and may not represent the views and policies of ORD and EPA. Concl...

  5. Analysis of bacterial vaginosis-related amines in vaginal fluid by gas chromatography and mass spectrometry.

    PubMed

    Wolrath, H; Forsum, U; Larsson, P G; Borén, H

    2001-11-01

    The presence of various amines in vaginal fluid from women with malodorous vaginal discharge has been reported before. The investigations have used several techniques to identify the amines. However, an optimized quantification, together with a sensitive analysis method in connection with a diagnostic procedure for vaginal discharge, including the syndrome of bacterial vaginosis, as defined by the accepted "gold standard," has not been done before. We now report a sensitive gas chromatographic and mass spectrometric method for identifying the amines isobutylamine, phenethylamine, putrescine, cadaverine, and tyramine in vaginal fluid. We used weighted samples of vaginal fluid to obtain a correct quantification. In addition, a proper diagnosis was obtained using Gram-stained smears of the vaginal fluid that were Nugent scored according to the method of Nugent et al. (R. P. Nugent et al., J. Clin. Microbiol., 29:297-301, 1991). We found that putrescine, cadaverine, and tyramine occurred in high concentrations in vaginal fluid from 24 women with Nugent scores between 7 and 10. These amines either were not found or were found only in very low concentrations in vaginal fluid from women with Nugent scores of 0 to 3. There is a strong correlation between bacterial vaginosis and the presence of putrescine, cadaverine, and tyramine in high concentrations in vaginal fluid.

  6. Quantitation of 5-Methyltetrahydrofolate in Cerebrospinal Fluid Using Liquid Chromatography-Electrospray Tandem Mass Spectrometry.

    PubMed

    Arning, Erland; Bottiglieri, Teodoro

    2016-01-01

    We describe a simple stable isotope dilution method for accurate and precise measurement of cerebrospinal fluid (CSF) 5-methyltetrahydrofolate (5-MTHF) as a clinical diagnostic test. 5-MTHF is the main biologically active form of folic acid and is involved in regulation of homocysteine and DNA synthesis. Measurement of 5-MTHF in CSF provides diagnostic information regarding diseases affecting folate metabolism within the central nervous system, in particular inborn errors of folate metabolism. Determination of 5-MTHF in CSF (50 μL) was performed utilizing high performance liquid chromatography coupled with electrospray positive ionization tandem mass spectrometry (HPLC-ESI-MS/MS). 5-MTHF in CSF is determined by a 1:2 dilution with internal standard (5-MTHF-(13)C5) and injected directly onto the HPLC-ESI-MS/MS system. Each assay is quantified using a five-point standard curve (25-400 nM) and has an analytical measurement range of 3-1000 nM.

  7. High temperature UF6 RF plasma experiments applicable to uranium plasma core reactors

    NASA Technical Reports Server (NTRS)

    Roman, W. C.

    1979-01-01

    An investigation was conducted using a 1.2 MW RF induction heater facility to aid in developing the technology necessary for designing a self critical fissioning uranium plasma core reactor. Pure, high temperature uranium hexafluoride (UF6) was injected into an argon fluid mechanically confined, steady state, RF heated plasma while employing different exhaust systems and diagnostic techniques to simulate and investigate some potential characteristics of uranium plasma core nuclear reactors. The development of techniques and equipment for fluid mechanical confinement of RF heated uranium plasmas with a high density of uranium vapor within the plasma, while simultaneously minimizing deposition of uranium and uranium compounds on the test chamber peripheral wall, endwall surfaces, and primary exhaust ducts, is discussed. The material tests and handling techniques suitable for use with high temperature, high pressure, gaseous UF6 are described and the development of complementary diagnostic instrumentation and measurement techniques to characterize the uranium plasma, effluent exhaust gases, and residue deposited on the test chamber and exhaust system components is reported.

  8. Monitoring Peptidase Activities in Complex Proteomes by MALDI-TOF Mass Spectrometry

    PubMed Central

    Villanueva, Josep; Nazarian, Arpi; Lawlor, Kevin; Tempst, Paul

    2009-01-01

    Measuring enzymatic activities in biological fluids is a form of activity-based proteomics and may be utilized as a means of developing disease biomarkers. Activity-based assays allow amplification of output signals, thus potentially visualizing low-abundant enzymes on a virtually transparent whole-proteome background. The protocol presented here describes a semi-quantitative in vitro assay of proteolytic activities in complex proteomes by monitoring breakdown of designer peptide-substrates using robotic extraction and a MALDI-TOF mass spectrometric read-out. Relative quantitation of the peptide metabolites is done by comparison with spiked internal standards, followed by statistical analysis of the resulting mini-peptidome. Partial automation provides reproducibility and throughput essential for comparing large sample sets. The approach may be employed for diagnostic or predictive purposes and enables profiling of 96 samples in 30 hours. It could be tailored to many diagnostic and pharmaco-dynamic purposes, as a read-out of catalytic and metabolic activities in body fluids or tissues. PMID:19617888

  9. Extensional rheometry with a handheld mobile device

    NASA Astrophysics Data System (ADS)

    Marshall, Kristin A.; Liedtke, Aleesha M.; Todt, Anika H.; Walker, Travis W.

    2017-06-01

    The on-site characterization of complex fluids is important for a number of academic and industrial applications. Consequently, a need exists to develop portable rheometers that can provide in the field diagnostics and serve as tools for rapid quality assurance. With the advancement of smartphone technology and the widespread global ownership of smart devices, mobile applications are attractive as platforms for rheological characterization. The present work investigates the use of a smartphone device for the extensional characterization of a series of Boger fluids composed of glycerol/water and poly(ethylene oxide), taking advantage of the increasing high-speed video capabilities (currently up to 240 Hz capture rate at 720p) of smartphone cameras. We report a noticeable difference in the characterization of samples with slight variations in polymer concentration and discuss current device limitations. Potential benefits of a handheld extensional rheometer include its use as a point-of-care diagnostic tool, especially in developing communities, as well as a simple and inexpensive tool for assessing product quality in industry.

  10. MOBILE ON-SITE RECYCLING OF METALWORKING FLUIDS

    EPA Science Inventory

    Product quality, waste reduction, and economic issues were evaluated for a technology designed to recycle metalworking fluids. mulsion-type fluids were tested at two sites and a synthetic fluid was tested at a third site. he specific recycling unit evaluated is based on the techn...

  11. Erythrocyte and Biochemical Abnormalities as Diagnostic Markers in Dogs With Hemangiosarcoma Related Hemoabdomen.

    PubMed

    Wong, Richard W; Gonsalves, Mishka N; Huber, Michael L; Rich, Lon; Strom, Adam

    2015-10-01

    To investigate: 1) acanthocytosis and presence of acanthocytes in peritoneal fluid as a diagnostic marker for hemangiosarcoma (HSA) in dogs with non-traumatic hemoabdomen; and 2) the association between other erythrocyte, biochemical, and hematologic abnormalities as a mean of differentiating HSA from other disease. Prospective double-blinded cohort study. Dogs (n = 40) with non-traumatic hemoabdomen. Dogs diagnosed with hemoabdomen (January 2012 to May 2013) had cytologic evaluation of abdominal effusion and peripheral blood smears. Peripheral blood CBC, PT, and aPTT, as well as blood and effusion acanthocytes, keratocytes, schistocytes, lactate, glucose, PCV, and TP results were compared using the paired t-test or Fisher's exact test. Based on histologic confirmation of HSA, dogs were divided into 2 groups (HSA, non-HSA) and variables compared. There was no significant difference in erythrocyte morphology in abdominal effusion or peripheral blood between dogs with HSA or non-HSA related hemoabdomen. Platelet concentration and peripheral blood PCV were significantly lower in the HSA group. A reliable preoperative biochemical or cytologic test to differentiate between HSA and non-HSA related hemoabdomen was not identified. © Copyright 2015 by The American College of Veterinary Surgeons.

  12. Effect of stenosis eccentricity on the functionality of coronary bifurcation lesions-a numerical study.

    PubMed

    Pagiatakis, Catherine; Tardif, Jean-Claude; L'Allier, Philippe L; Mongrain, Rosaire

    2017-12-01

    Interventional cardiologists still rely heavily on angiography for the evaluation of coronary lesion severity, despite its poor correlation with the presence of ischemia. In order to improve the accuracy of the current diagnostic procedures, an understanding of the relative influence of geometric characteristics on the induction of ischemia is required. This idea is especially important for coronary bifurcation lesions (CBLs), whose treatment is complex and is associated with high rates of peri- and post-procedural clinical events. Overall, it is unclear which geometric and morphological parameters of CBLs influence the onset of ischemia. More specifically, the effect of stenosis eccentricity is unknown. Computational fluid dynamic simulations, under a geometric multiscale framework, were executed for seven CBL configurations within the left main coronary artery bifurcation. Both concentric and eccentric stenosis profiles of mild to severe constriction were considered. By using a geometric multiscale framework, the fractional flow reserve, which is the gold-standard clinical diagnostic index, could be calculated and was compared between the eccentric and concentric profiles for each case. The results suggested that for configurations where the supplying vessel is stenosed, eccentricity could have a notable effect on and therefore be an important factor that influences configuration functionality.

  13. Laser Rayleigh and Raman Diagnostics for Small Hydrogen/oxygen Rockets

    NASA Technical Reports Server (NTRS)

    Degroot, Wilhelmus A.; Zupanc, Frank J.

    1993-01-01

    Localized velocity, temperature, and species concentration measurements in rocket flow fields are needed to evaluate predictive computational fluid dynamics (CFD) codes and identify causes of poor rocket performance. Velocity, temperature, and total number density information have been successfully extracted from spectrally resolved Rayleigh scattering in the plume of small hydrogen/oxygen rockets. Light from a narrow band laser is scattered from the moving molecules with a Doppler shifted frequency. Two components of the velocity can be extracted by observing the scattered light from two directions. Thermal broadening of the scattered light provides a measure of the temperature, while the integrated scattering intensity is proportional to the number density. Spontaneous Raman scattering has been used to measure temperature and species concentration in similar plumes. Light from a dye laser is scattered by molecules in the rocket plume. Raman spectra scattered from major species are resolved by observing the inelastically scattered light with linear array mounted to a spectrometer. Temperature and oxygen concentrations have been extracted by fitting a model function to the measured Raman spectrum. Results of measurements on small rockets mounted inside a high altitude chamber using both diagnostic techniques are reported.

  14. Utility of Lumbar Puncture in Children Presenting With Status Epilepticus.

    PubMed

    Michelson, Kenneth A; Lyons, Todd W; Johnson, Kara B; Nigrovic, Lise E; Harper, Marvin B; Kimia, Amir A

    2017-08-01

    Because meningitis may trigger seizures, we sought to determine its frequency in children with first-time status epilepticus (SE). We performed a retrospective cross-sectional study of children aged 1 month to 21 years who presented to a single pediatric emergency department between 1995 and 2012 with SE and who had a lumbar puncture (LP) performed as part of the diagnostic evaluation. We defined bacterial meningitis as a cerebrospinal fluid (CSF) culture positive for a bacterial pathogen or CSF pleocytosis (CSF white blood cells ≥10 cells/mm) with a blood culture positive for a bacterial pathogen. We defined viral meningitis or encephalitis using a positive enterovirus or herpes simplex virus polymerase chain reaction test. Among 126 children with SE who had an LP performed, 8 (6%) had CSF pleocytosis. Of these, 5 had received antibiotics before performance of a diagnostic LP. One child in the cohort was proven to have bacterial meningitis (0.8%; 95% confidence interval [CI], 0%-6%). Two other children had enteroviral meningitis (2/13 tested, 15%; 95% CI, 3%-51%), and 1 had a herpes simplex virus infection (1/47, 2%; 95% CI, 0%-15%). Bacterial meningitis is an uncommon cause of SE.

  15. Improving early cycle economic evaluation of diagnostic technologies.

    PubMed

    Steuten, Lotte M G; Ramsey, Scott D

    2014-08-01

    The rapidly increasing range and expense of new diagnostics, compels consideration of a different, more proactive approach to health economic evaluation of diagnostic technologies. Early cycle economic evaluation is a decision analytic approach to evaluate technologies in development so as to increase the return on investment as well as patient and societal impact. This paper describes examples of 'early cycle economic evaluations' as applied to diagnostic technologies and highlights challenges in its real-time application. It shows that especially in the field of diagnostics, with rapid technological developments and a changing regulatory climate, early cycle economic evaluation can have a guiding role to improve the efficiency of the diagnostics innovation process. In the next five years the attention will move beyond the methodological and analytic challenges of early cycle economic evaluation towards the challenge of effectively applying it to improve diagnostic research and development and patient value. Future work in this area should therefore be 'strong on principles and soft on metrics', that is, the metrics that resonate most clearly with the various decision makers in this field.

  16. Reliability of HIV rapid diagnostic tests for self-testing compared with testing by health-care workers: a systematic review and meta-analysis.

    PubMed

    Figueroa, Carmen; Johnson, Cheryl; Ford, Nathan; Sands, Anita; Dalal, Shona; Meurant, Robyn; Prat, Irena; Hatzold, Karin; Urassa, Willy; Baggaley, Rachel

    2018-06-01

    The ability of individuals to use HIV self-tests correctly is debated. To inform the 2016 WHO recommendation on HIV self-testing, we assessed the reliability and performance of HIV rapid diagnostic tests when used by self-testers. In this systematic review and meta-analysis, we searched PubMed, PopLine, and Embase, conference abstracts, and additional grey literature between Jan 1, 1995, and April 30, 2016, for observational and experimental studies reporting on HIV self-testing performance. We excluded studies evaluating home specimen collection because patients did not interpret their own test results. We extracted data independently, using standardised extraction forms. Outcomes of interest were agreement between self-testers and health-care workers, sensitivity, and specificity. We calculated κ to establish the level of agreement and pooled κ estimates using a random-effects model, by approach (directly assisted or unassisted) and type of specimen (blood or oral fluid). We examined heterogeneity with the I 2 statistic. 25 studies met inclusion criteria (22 to 5662 participants). Quality assessment with QUADAS-2 showed studies had low risk of bias and incomplete reporting in accordance with the STARD checklist. Raw proportion of agreement ranged from 85·4% to 100%, and reported κ ranged from fair (κ 0·277, p<0·001) to almost perfect (κ 0·99, n=25). Pooled κ suggested almost perfect agreement for both types of approaches (directly assisted 0·98, 95% CI 0·96-0·99 and unassisted 0·97, 0·96-0·98; I 2 =34·5%, 0-97·8). Excluding two outliers, sensitivity and specificity was higher for blood-based rapid diagnostic tests (4/16) compared with oral fluid rapid diagnostic tests (13/16). The most common error that affected test performance was incorrect specimen collection (oral swab or finger prick). Study limitations included the use of different reference standards and no disaggregation of results by individuals taking antiretrovirals. Self-testers can reliably and accurately do HIV rapid diagnostic tests, as compared with trained health-care workers. Errors in performance might be reduced through the improvement of rapid diagnostic tests for self-testing, particularly to make sample collection easier and to simplify instructions for use. The Bill & Melinda Gates Foundation and Unitaid. © 2018. World Health Oranization. Licensee Elseviere. This is an Open Access article published under the CC BY 3.0 IGO license which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. In any use of this article, there should be no suggestion that WHO endorses any specific organisation, products or services. The use of the WHO logo is not permitted. This notice should be preserved along with the article's original URL.

  17. An Overview of the Clinical Use of Filter Paper in the Diagnosis of Tropical Diseases

    PubMed Central

    Smit, Pieter W.; Elliott, Ivo; Peeling, Rosanna W.; Mabey, David; Newton, Paul N.

    2014-01-01

    Tropical infectious diseases diagnosis and surveillance are often hampered by difficulties of sample collection and transportation. Filter paper potentially provides a useful medium to help overcome such problems. We reviewed the literature on the use of filter paper, focusing on the evaluation of nucleic acid and serological assays for diagnosis of infectious diseases using dried blood spots (DBS) compared with recognized gold standards. We reviewed 296 eligible studies and included 101 studies evaluating DBS and 192 studies on other aspects of filter paper use. We also discuss the use of filter paper with other body fluids and for tropical veterinary medicine. In general, DBS perform with sensitivities and specificities similar or only slightly inferior to gold standard sample types. However, important problems were revealed with the uncritical use of DBS, inappropriate statistical analysis, and lack of standardized methodology. DBS have great potential to empower healthcare workers by making laboratory-based diagnostic tests more readily accessible, but additional and more rigorous research is needed. PMID:24366501

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Risacher, Shannon L.; Kim, Sungeun; Nho, Kwangsik

    This study assessed apolipoprotein E (APOE) ε4 carrier status effects on Alzheimer's disease imaging and cerebrospinal fluid (CSF) biomarkers in cognitively normal older adults with significant memory concerns (SMC). Cognitively normal, SMC, and early mild cognitive impairment participants from Alzheimer's Disease Neuroimaging Initiative were divided by APOE ε4 carrier status. Diagnostic and APOE effects were evaluated with emphasis on SMC. Additional analyses in SMC evaluated the effect of the interaction between APOE and [ 18F]Florbetapir amyloid positivity on CSF biomarkers. SMC ε4+ showed greater amyloid deposition than SMC ε4-, but no hypometabolism or medial temporal lobe (MTL) atrophy. SMC ε4+more » showed lower amyloid beta 1-42 and higher tau/p-tau than ε4-, which was most abnormal in APOE ε4+ and cerebral amyloid positive SMC. Lastly, SMC APOE ε4+ show abnormal changes in amyloid and tau biomarkers, but no hypometabolism or MTL neurodegeneration, reflecting the at-risk nature of the SMC group and the importance of APOE in mediating this risk.« less

  19. Evaluation of Turner relaxed state as a model of long-lived ion-trapping structures in plasma focus and Z-pinches

    NASA Astrophysics Data System (ADS)

    Auluck, S. K. H.

    2011-03-01

    Relatively long-lived spheroidal structures coincident with the neutron emission phase have been observed in frozen deuterium fiber Z-pinch and some plasma focus devices. Existence of energetic ion-trapping mechanism in plasma focus has also been inferred from experimental data. It has been conjectured that these are related phenomena. This paper applies Turner's theory [L. Turner, IEEE Trans. Plasma Sci. 14, 849 (1986)] of relaxation of a Hall magnetofluid to construct a model of these structures and ion-trapping mechanism. Turner's solution modified for a finite-length plasma is used to obtain expressions for the magnetic field, velocity, and equilibrium pressure fields and is shown to represent an entity which is simultaneously a fluid vortex, a force-free magnetic field, a confined finite-pressure plasma, a charged object, and a trapped energetic ion beam. Characteristic features expected from diagnostic experiments are evaluated and shown to resemble experimental observations.

  20. Diagnostic and therapeutic value of laparoscopy for small bowel blunt injuries: A case report.

    PubMed

    Addeo, Pietro; Calabrese, Daniela Paola

    2011-01-01

    Small bowel injuries after blunt abdominal trauma represent both a diagnostic and a therapeutic challenge. Early diagnosis and prompt treatment are necessary in order to avoid a dangerous diagnostic delay. Laparoscopy can represent a diagnostic and therapeutic tool in patients with uncertain clinical symptoms. We report the case of a 25-year-old man, haemodynamically stable, admitted for acute abdominal pain a few hours after a physical assault. Giving the persistence of the abdominal pain and the presence of free fluids at the computed tomography examination, an exploratory laparoscopy was performed. At the laparoscopic exploration, an isolated small bowel perforation was found, 60 cm distal from the ligament of Treitz. The injury was repaired by laparoscopic suturing and the patient was discharged home at postoperative day 3 after an uneventful postoperative course. Laparoscopy represents a valuable tool for patients with small bowel blunt injuries allowing a timely diagnosis and a prompt treatment.

Top