Ice Detector and Deicing Fluid Effectiveness Monitoring System
NASA Technical Reports Server (NTRS)
Seegmiller, H. Lee B. (Inventor)
1996-01-01
An ice detector and deicing fluid effectiveness monitoring system for an aircraft is disclosed. The ice detection portion is particularly suited for use in flight to notify the flight crew of an accumulation of ice on an aircraft lifting and control surfaces, or helicopter rotors, whereas the deicing fluid effectiveness monitoring portion is particularly suited for use on the ground to notify the flight crew of the possible loss of the effectiveness of the deicing fluid. The ice detection portion comprises a temperature sensor and a parallel arrangement of electrodes whose coefficient of coupling is indicative of the formation of the ice, as well as the thickness of the formed ice. The fluid effectiveness monitoring portion comprises a temperature sensor and an ionic-conduction cell array that measures the conductivity of the deicing fluid which is indicative of its concentration and, thus, its freezing point. By measuring the temperature and having knowledge of the freezing point of the deicing fluid, the fluid effectiveness monitoring portion predicts when the deicing fluid may lose its effectiveness because its freezing point may correspond to the temperature of the ambient.
Assessment of Fluid Balance and the Approach to Fluid Therapy in the Perioperative Patient.
Boller, Elise; Boller, Manuel
2015-09-01
Perioperative patients can be highly dynamic and have various metabolic, physiologic, and organ system derangements that necessitate smart monitoring strategies and careful fluid therapy. The interplay between changing patient status, therapeutic interventions, and patient response makes effective monitoring crucial to successful treatment. Monitoring the perioperative patient and an approach to fluid therapy are discussed in this text. Copyright © 2015 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Yamada, K.; Endo, T.; Imai, H.; Kido, M.; Jeong, H.; Ohno, Y.
2016-03-01
We have developed the point-of-care therapeutic drug monitoring kit based on Raman Spectroscopy of tear fluid. In this study, we were examined a soft substrate for an optimal lattice based on nanoimprint lithography using cyclo-olefin polymer to improve the sensitivity for measuring drug concentration in tear fluid. This is photonics crystal which is one of the nano-photonics based device was fabricated. Target is Sodium Phenobarbital which is an anticonvulsant agent. We show the effectiveness of Surface Enhanced Raman Spectroscopy of tear fluid with soft substrate for point-of-care therapeutic drug monitoring.
Woonwong, Yonlayong; Kedkovid, Roongtham; Arunorat, Jirapat; Sirisereewan, Chaitawat; Nedumpun, Teerawut; Poonsuk, Korakrit; Panyasing, Yaowalak; Poolperm, Pariwat; Boonsoongnern, Alongkot; Thanawongnuwech, Roongroje
2018-02-01
An effective gilt acclimatization program is one of the most important management strategies for controlling porcine reproductive and respiratory syndrome virus (PRRSV) infection. Recently, oral fluid samples have been used as alternative diagnostic samples for various swine diseases. This study utilized oral fluids for PRRSV monitoring during the gilt acclimatization period in PRRSV endemic farms. The study was performed in two selected commercial breeding herds (farm A and farm B). PRRSV RNA and PRRSV-specific antibodies were monitored using oral fluid and serum samples. Sow performance parameters related to PRRSV infection were recorded and assessed. After PRRSV exposure during acclimatization, viral RNA was demonstrated in oral fluids from 1 to 10 weeks post-exposure (WPE). PRRSV RNA was detected in serum at 1 and 4 WPE in farm A and at 1, 4, 8, and 12 WPE in farm B. Prolonged viremia of gilts from farm B was possibly due to re-infection (within the herd) and later, reproductive problems were found in the breeding herd. The correlation of PRRSV RNA concentration in oral fluids and serum was evident. The S/P ratio values of PRRSV antibodies in oral fluid samples were higher and had similar patterns of antibody responses to the serum samples. The results suggest that the use of oral fluid samples for PRRSV monitoring during gilt acclimatization in endemic farms is effective, convenient, practical, and economical and would be most beneficial when used with other parameters.
NASA Astrophysics Data System (ADS)
Zhao, Luanxiao; Yuan, Hemin; Yang, Jingkang; Han, De-hua; Geng, Jianhua; Zhou, Rui; Li, Hui; Yao, Qiuliang
2017-11-01
Conventional seismic analysis in partially saturated rocks normally lays emphasis on estimating pore fluid content and saturation, typically ignoring the effect of mobility, which decides the ability of fluids moving in the porous rocks. Deformation resulting from a seismic wave in heterogeneous partially saturated media can cause pore fluid pressure relaxation at mesoscopic scale, thereby making the fluid mobility inherently associated with poroelastic reflectivity. For two typical gas-brine reservoir models, with the given rock and fluid properties, the numerical analysis suggests that variations of patchy fluid saturation, fluid compressibility contrast, and acoustic stiffness of rock frame collectively affect the seismic reflection dependence on mobility. In particular, the realistic compressibility contrast of fluid patches in shallow and deep reservoir environments plays an important role in determining the reflection sensitivity to mobility. We also use a time-lapse seismic data set from a Steam-Assisted Gravity Drainage producing heavy oil reservoir to demonstrate that mobility change coupled with patchy saturation possibly leads to seismic spectral energy shifting from the baseline to monitor line. Our workflow starts from performing seismic spectral analysis on the targeted reflectivity interface. Then, on the basis of mesoscopic fluid pressure diffusion between patches of steam and heavy oil, poroelastic reflectivity modeling is conducted to understand the shift of the central frequency toward low frequencies after the steam injection. The presented results open the possibility of monitoring mobility change of a partially saturated geological formation from dissipation-related seismic attributes.
4D ERT-based calibration and prediction of biostimulant induced changes in fluid conductivity
NASA Astrophysics Data System (ADS)
Johnson, T. C.; Versteeg, R. J.; Day-Lewis, F. D.; Major, W. R.; Wright, K. E.
2008-12-01
In-situ bioremediation is an emerging and cost-effective method of removing organic contaminants from groundwater. The performance of bioremedial systems depends on the adequate delivery and distribution of biostimulants to contaminated zones. Monitoring the distribution of biostimulants using monitoring wells is expensive, time consuming, and provides inadequate information between sampling wells. We discuss a Hydrogeophysical Performance Monitoring System (HPMS) deployed to monitor bioremediation efforts at a TCE-contaminated Superfund site in Brandywine MD. The HPMS enables autonomous electrical geophysical data acquisition, processing, quality-assurance/quality-control, and inversion. Our objective is to demonstrate the feasibility and cost effectiveness of the HPMS to provide near real-time information on the spatiotemporal behavior of injected biostimulants. As a first step, we use time-lapse electrical resistivity tomography (ERT) to estimate changes in bulk conductivity caused by the injectate. We demonstrate how ERT-based bulk conductivity estimates can be calibrated with a small number of fluid conductivity measurements to produce ERT-based estimates of fluid conductivity. The calibration procedure addresses the spatially variable resolution of the ERT tomograms. To test the validity of these estimates, we used the ERT results to predict the fluid conductivity at tens of points prior to field sampling of fluid conductivity at the same points. The comparison of ERT-predicted vs. observed fluid conductivity displays a high degree of correlation (correlation coefficient over 0.8), and demonstrates the ability of the HPMS to estimate the four-dimensional (4D) distribution of fluid conductivity caused by the biostimulant injection.
21 CFR 880.2460 - Electrically powered spinal fluid pressure monitor.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Electrically powered spinal fluid pressure monitor... Personal Use Monitoring Devices § 880.2460 Electrically powered spinal fluid pressure monitor. (a) Identification. An electrically powered spinal fluid pressure monitor is an electrically powered device used to...
Kunkel, Frank; Fey, Elizabeth; Borg, Damon; Stripp, Richard; Getto, Christine
2015-01-01
Drug testing is an important clinical tool that is available to physicians who are assessing the effectiveness of drug treatment as well as patient compliance to the administered program. While urine has traditionally been the matrix of choice for drug monitoring, oral fluid, a filtrate of the blood, has shown great promise as an alternative matrix for such applications. Oral fluid collection can be accomplished without the need for highly trained medical staff through the use of a simple, noninvasive oral fluid collection device, which obtains an adequate sample in only a few minutes. There has been a significant amount of research performed on the use of oral fluid for forensic toxicology application; however, more studies assessing the use of oral fluid drug testing are required to validate its ability to achieve clinical drug monitoring goals. Testing for various drugs in oral fluid may yield a different result when compared to the same drugs in urine, requiring an assessment of the utility of oral fluid for such practices. The purpose of this study was to examine the application of oral fluid drug testing in patients undergoing buprenorphine treatment for opioid dependence. A retrospective analysis of drug testing results obtained from 6,928 patients (4,560 unobserved urine collections and 2,368 observed oral fluid collections) monitored for heroin metabolite, amphetamine, benzodiazepines, buprenorphine, tetrahydrocannabinol, cocaine, codeine, hydrocodone, hydromorphone, methadone, morphine, oxycodone, and oxymorphone was completed. Results of this statistical exercise indicated that patients undergoing observed oral fluid collection tested positive more frequently than those unobserved urine collections for several illicit drugs and prescription medications targeted. Oral fluid was shown to detect illicit drug use as well as noncompliance in this patient population under the studied conditions more often than the urine specimens.
Monitoring artificially stimulated fluid movement in the Cretaceous Dakota aquifer, western Kansas
Macfarlane, P.A.; Forster, A.; Merriam, D.F.; Schrotter, J.; Healey, J.M.
2002-01-01
Aquifer properties can be evaluated by monitoring artificially stimulated fluid movements between wells, if the fluid is heated. Changes in the temperature profile recorded in observation wells indicate the flow path of the heated fluid, which in effect acts as a tracer. A fluid-flow experiment in the Cretaceous Dakota Formation at the Hodgeman County site, west-central Kansas, demonstrated the advantage of using the distributed optical-fiber temperature sensing method for monitoring transient temperature conditions in his hydrological application. The fluid flow in the aquifer was increased by producing water from a pumping well and injecting heated water in an injection well 13 m (43 ft) distant from the pumping well. The time-temperature series data obtained and compared with results from previous pumping tests point to interwell heterogeneity of the aquifer and to a zone in the sandstone aquifer of high hydraulic conductivity. However, the experiment would have allowed further clarification of aquifer heterogeneity and thermal properties if at least one observation well had been present between the injection and production wells.
NASA Astrophysics Data System (ADS)
Schmidt-Hattenberger, C.; Weiner, M.; Liebscher, A.; Spangenberg, E.
2009-04-01
A fiber optic refractive index sensor is tested for continuous monitoring of fluid-fluid and fluid-gas interactions within the frame of laboratory investigations of CO2 storage, monitoring and safety technology research (COSMOS project, "Geotechnologien" program). The sensor bases on a Fabry-Perot white light interferometer technique, where the refractive index (RI) of the solution under investigation is measured by variation of the liquid-filled Fabry-Perot optical cavity length. Such sensor system is typically used for measuring and controlling oil composition and also fluid quality. The aim of this study is to test the application of the fiber optic refractive index sensor for monitoring the CO2 dissolution in formation fluids (brine, oil, gas) of CO2 storage sites. Monitoring and knowledge of quantity and especially rate of CO2 dissolution in the formation fluid is important for any assessment of long-term risks of CO2 storage sites. It is also a prerequisite for any precise reservoir modelling. As a first step we performed laboratory experiments in standard autoclaves on a variety of different fluids and fluid mixtures (technical alcohols, pure water, CO2, synthetic brines, natural formation brine from the Ketzin test site). The RI measurements are partly combined with default electrical conductivity and sonic velocity measurements. The fiber optic refractive index sensor system allows for RI measurements within the range 1.0000 to 1.7000 RI with a resolution of approximately 0.0001 RI. For simple binary fluid mixtures first results indicate linear relationships between refractive indices and fluid composition. Within the pressure range investigated (up to 60 bar) the data suggest only minor changes of RI with pressure. Further, planned experiments will focus on the determination of i) the temperature dependency of RI, ii) the combined effects of pressure and temperature on RI, and finally iii) the kinetics of CO2 dissolution in realistic formation fluids.
[A non-invasive portable blood-glucose monitoring system: sampling of suction effusion fluid].
Arai, T; Kayashima, S; Kikuchi, M; Kaneyoshi, A; Itoh, N
1995-04-01
We developed a new portable transcutaneous blood glucose monitoring system using non-invasive collection of suction effusion fluid (SEF) from human skin. A ion sensitive field effect transistor (ISFET) sensor was employed to measure glucose concentration in a very small quantity of the SEF. The system was composed of a couple of portions. One structure was a suction cell, and the other was a main frame. The suction cell included the ISFET glucose sensor, a dilution mechanism, and a sucking interface to human skin. The main frame contained a dilution solution reservoir, a liquid waste reservoir, a fluid pump, a vacuum pump, a micro processor, batteries, and a user interface. The system is self-contained for portable usage during up to 6 hrs monitoring. This system may be the first blood glucose monitoring equipment which does not use blood sampling.
Controlled Source Electromagnetic Monitoring of Hydraulic Fracturing: Wellbore and Fluid Effects
NASA Astrophysics Data System (ADS)
Couchman, M. J.; Everett, M. E.
2017-12-01
As unconventional resources become increasingly important, we must tackle the issue of real-time monitoring of the efficiency of unconventional hydrocarbon extraction. Controlled Source Electromagnetics (CSEM) have been used primarily as a marine-based technique to monitor conventional oil bearing reservoirs with a strong resurgence the new millennium. Many of these studies revolving around detecting a thin resistive layer such as a reservoir at 1m - 3km depth. In these cases, the presence of the resistive layer is characterized by a jump in electric field amplitude recorded at the boundary between the layer and the host sediments. The lessons learned from these studies can be applied to terrestrial unconventional settings with appropriate modifications. The work shown here is a means develop methods which enable more reliable terrestrial CSEM monitoring of the flow of injected fluids associated with hydraulic fracturing of unconventional reservoirs and to detect subsurface fluids based on their CSEM signature and in turn, to infer the subsurface flow of electrically conductive injected fluids. The predictive model validated for various 1-D marine, and terrestrial cases focus on the mapping of fluid flow in from a horizontal wellbore in a uniform halfspace using an in-line Horizontal Electric Dipole (HED) with electric field amplitude recorded by an array of electric field sensors. The effect of the of the vertical and horizontal wellbores are documented taking into account the conductivity, size, and thickness of each wellbore. The fracturing fluids flow and conductivity are also taken into account throughout various stages of the fracturing process. In each case, the sensitivity at a location of the surface in-line electric field to a given resistive or conductive layer, due to a source is calculated.
NASA Astrophysics Data System (ADS)
Bravo-Berguño, D.; Mereu, R.; Cavalcante, P.; Carlini, M.; Ianni, A.; Goretti, A.; Gabriele, F.; Wright, T.; Yokley, Z.; Vogelaar, R. B.; Calaprice, F.; Inzoli, F.
2018-03-01
A comprehensive monitoring system for the thermal environment inside the Borexino neutrino detector was developed and installed in order to reduce uncertainties in determining temperatures throughout the detector. A complementary thermal management system limits undesirable thermal couplings between the environment and Borexino's active sections. This strategy is bringing improved radioactive background conditions to the region of interest for the physics signal thanks to reduced fluid mixing induced in the liquid scintillator. Although fluid-dynamical equilibrium has not yet been fully reached, and thermal fine-tuning is possible, the system has proven extremely effective at stabilizing the detector's thermal conditions while offering precise insights into its mechanisms of internal thermal transport. Furthermore, a Computational Fluid-Dynamics analysis has been performed, based on the empirical measurements provided by the thermal monitoring system, and providing information into present and future thermal trends. A two-dimensional modeling approach was implemented in order to achieve a proper understanding of the thermal and fluid-dynamics in Borexino. It was optimized for different regions and periods of interest, focusing on the most critical effects that were identified as influencing background concentrations. Literature experimental case studies were reproduced to benchmark the method and settings, and a Borexino-specific benchmark was implemented in order to validate the modeling approach for thermal transport. Finally, fully-convective models were applied to understand general and specific fluid motions impacting the detector's Active Volume.
Effect of repeated arthrocentesis on cytologic analysis of synovial fluid in dogs.
Berg, R I M; Sykes, J E; Kass, P H; Vernau, W
2009-01-01
Serial arthrocentesis and synovial fluid examination can be used to monitor treatment efficacy in immune-mediated polyarthritis (IMPA), but whether this procedure induces inflammation that interferes with test result interpretation is unknown. The aim of this study was to determine the effect of repeated arthrocentesis on synovial fluid cytology in healthy dogs. Nine healthy client-owned dogs. Prospective study. Arthrocentesis was performed under sedation on 4 joints (both carpi, 1 tarsus, 1 stifle) on each dog every 3 weeks, a total of 4 times. Automated cell counts were done on stifle fluid, smears were made, and differential cell counts done on smears from all joints. Slides were evaluated microscopically for erythrocyte numbers, total nucleated cell count, differential cell count, and cell morphology. Data were analyzed by 2-way analysis of variance. A total of 144 synovial fluid samples were examined. Repeated arthrocentesis was not associated with increases in synovial fluid neutrophil numbers. Mild mononuclear inflammation was detected in 13 samples from 6 dogs. Serial arthrocentesis at 3-week intervals can rarely be associated with mild mononuclear joint inflammation, but does not appear to induce neutrophilic inflammation, at least in healthy dogs, and can be useful to monitor treatment response in canine IMPA.
Time-lapse 3-D seismic imaging of shallow subsurface contaminant flow.
McKenna, J; Sherlock, D; Evans, B
2001-12-01
This paper presents a physical modelling study outlining a technique whereby buoyant contaminant flow within water-saturated unconsolidated sand was remotely monitored utilizing the time-lapse 3-D (TL3-D) seismic response. The controlled temperature and pressure conditions, along with the high level of acquisition repeatability attainable using sandbox physical models, allow the TL3-D seismic response to pore fluid movement to be distinguished from all other effects. TL3-D seismic techniques are currently being developed to monitor hydrocarbon reserves within producing reservoirs in an endeavour to improve overall recovery. However, in many ways, sandbox models under atmospheric conditions more accurately simulate the shallow subsurface than petroleum reservoirs. For this reason, perhaps the greatest application for analogue sandbox modelling is to improve our understanding of shallow groundwater and environmental flow mechanisms. Two fluid flow simulations were conducted whereby air and kerosene were injected into separate water-saturated unconsolidated sand models. In both experiments, a base 3-D seismic volume was recorded and compared with six later monitor surveys recorded while the injection program was conducted. Normal incidence amplitude and P-wave velocity information were extracted from the TL3-D seismic data to provide visualization of contaminant migration. Reflection amplitudes displayed qualitative areal distribution of fluids when a suitable impedance contrast existed between pore fluids. TL3-D seismic reflection tomography can potentially monitor the change in areal distribution of fluid contaminants over time, indicating flow patterns. However, other research and this current work have not established a quantifiable relationship between either normal reflection amplitudes and attenuation and fluid saturation. Generally, different pore fluids will have unique seismic velocities due to differences in compressibility and density. The predictable relationships that exist between P-wave velocity and fluid saturation can allow a quantitative assessment of contaminant migration.
NASA Astrophysics Data System (ADS)
De Siena, Luca; Rawlinson, Nicholas
2016-04-01
Non-standard seismic imaging (velocity, attenuation, and scattering tomography) of the North Sea basins by using unexploited seismic intensities from previous passive and active surveys are key for better imaging and monitoring fluid under the subsurface. These intensities provide unique solutions to the problem of locating/tracking gas/fluid movements in the crust and depicting sub-basalt and sub-intrusives in volcanic reservoirs. The proposed techniques have been tested in volcanic Islands (Deception Island) and have been proved effective at monitoring fracture opening, imaging buried fluid-filled bodies, and tracking water/gas interfaces. These novel seismic attributes are modelled in space and time and connected with the lithology of the sampled medium, specifically density and permeability with as key output a novel computational code with strong commercial potential.
NASA Astrophysics Data System (ADS)
Pagola, Iñigo; Funcia, Ibai; Sánchez, Marcelino; Gil, Javier; González-Vallejo, Victoria; Bedoya, Maxi; Orellana, Guillermo
2017-06-01
The work presented in this paper offers a robust, effective and economically competitive method for online detection and monitoring of the presence of molecular hydrogen in the heat transfer fluids of parabolic trough collector plants. The novel method is based on a specific fluorescent sensor according to the ES2425002 patent ("Method for the detection and quantification of hydrogen in a heat transfer fluid").
Intravenous maintenance fluid therapy in children.
McNab, Sarah
2016-02-01
Intravenous fluids are frequently used in paediatrics but have been associated with significant adverse outcomes. Understanding the composition of fluid prescribed and administering an appropriate rate is essential for safe fluid administration, along with regular monitoring. Recent evidence has shown that using an isotonic fluid with a sodium concentration similar to plasma can decrease the risk of hyponatraemia without an increase in adverse effects. This should lead to a change in guidelines: isotonic fluid should now be used as the primary maintenance intravenous fluid given to the majority of children. © 2016 The Author Journal of Paediatrics and Child Health © 2016 Paediatrics and Child Health Division (Royal Australasian College of Physicians).
Thanigaimani, K; Mohamed, F; Cecil, T; Moran, B J; Bell, J
2013-12-01
The optimal strategy for intravenous (IV) fluid management during administration of hyperthermic intraperitoneal chemotherapy (HIPEC) is unclear. In this prospective study we describe the use of a LiDCOrapid™ (LiDCO, Cambridge, UK) cardiac output monitor to guide IV fluid management during cytoreductive surgery (CRS) with HIPEC. The aim of this study was to determine whether cardiac output monitoring will allow close maintenance of physiological parameters during the HIPEC phase. Twenty-five patients who underwent CRS combined with HIPEC were included in the study. Intra-operative IV fluid boluses were titrated using parameters measured by the LiDCOrapid™ monitor. Stroke volume variation was maintained below 10% with fluid boluses and mean arterial pressure was maintained within 20% of the baseline figure with vasopressors. There was no significant change in heart rate and cardiac output. The systemic vascular resistance dropped from an average of 966 dyn.s/cm-5 to 797 dyn s/cm(5) at 60 min during the HIPEC phase (P = 0.62) despite an increase in the dose of phenylepherine. The average total volume of fluid given was 748 ml in the first 30 min and 630 ml in the second 30 min with an average urine output of 307 and 445 ml, respectively. The change in lactate levels was not statistically or clinically significant. LiDCOrapid™ is an effective noninvasive tool for guiding fluid management in this population. It allows the anaesthesiologist to maintain tight control of essential physiological parameters during a phase of the procedure in which there is a risk of renal injury. Colorectal Disease © 2013 The Association of Coloproctology of Great Britain and Ireland.
A Noninvasive Method to Study Regulation of Extracellular ...
Time-domain nuclear magnetic resonance (TD-NMR)-based measurement of body composition of rodents is an effective method to quickly and repeatedly measure proportions of fat, lean, and fluid without anesthesia. TD-NMR provides a measure of free water in a living animal, termed % fluid, and is a measure of unbound water in the vascular and extracelular spaces. We hypothesized that injecting a bolus of fluid into the peritoneal cavity would lead to an abrupt increase in %fluid and the rate of clearance monitored with TD-NMR would provide a noninvasive assessment of the free water homeostasis in an awake rat. Several strains of laboratory rats were injected intraperitoneally with 10 ml/kg isotonic or hypertonic saline and % fluid was monitored repeatedly with a Bruker "Minispec" TD-NMR body composition system.Following isotonic saline, %fluid increased immediately by 0.5% followed by a recovery over ~6h. Injecting hypertonic (3 times normal saline) resulted in a significantly greater rise in %fluid and longer recovery. lntraperitoneal and subcutaneous fluid injection led to similar rates of clearance. The Wistar-Kyoto rat strain displayed significantly slower recovery to fluid loads compared with Long-Evans and Sprague-Dawley strains. Rats exercised chronically showed significant increases in %fluid, but the rate of clearance of fluid was similar to that of sedentary animals. We conclude that this technique could be used to study vascular and extracellular volume ho
Real-time surrogate analysis for potential oil and gas contamination of drinking water resources
NASA Astrophysics Data System (ADS)
Son, Ji-Hee; Carlson, Kenneth H.
2015-09-01
Public concerns related to the fast-growing shale oil and gas industry have increased during recent years. The major concern regarding shale gas production is the potential of fracturing fluids being injected into the well or produced fluids flowing out of the well to contaminate drinking water resources such as surface water and groundwater. Fracturing fluids contain high total dissolved solids (TDS); thus, changes in TDS concentrations in groundwater might indicate influences of fracturing fluids. An increase of methane concentrations in groundwater could also potentially be due to hydraulic fracturing activities. To understand the possible contamination of groundwater by fracturing activities, real-time groundwater monitoring is being implemented in the Denver-Julesburg basin of northeast Colorado. A strategy of monitoring of surrogate parameters was chosen instead of measuring potential contaminants directly, an approach that is not cost effective or operationally practical. Contaminant surrogates of TDS and dissolved methane were proposed in this study, and were tested for correlation and data distribution with laboratory experiments. Correlations between TDS and electrical conductivity (EC), and between methane contamination and oxidation-reduction potential (ORP) were strong at low concentrations of contaminants (1 mg/L TDS and 0.3 mg/L CH4). Dissolved oxygen (DO) was only an effective surrogate at higher methane concentrations (≥2.5 mg/L). The results indicated that EC and ORP are effective surrogates for detecting concentration changes of TDS and methane, respectively, and that a strategy of monitoring for easy to measure parameters can be effective detecting real-time, anomalous behavior relative to a predetermined baseline.
30 CFR 250.457 - What equipment is required to monitor drilling fluids?
Code of Federal Regulations, 2010 CFR
2010-07-01
... OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Oil and Gas Drilling Operations Drilling Fluid Requirements § 250.457 What equipment is required to monitor drilling fluids? Once you... 30 Mineral Resources 2 2010-07-01 2010-07-01 false What equipment is required to monitor drilling...
NASA Astrophysics Data System (ADS)
Goto, S.; Hamamoto, H.; Yamano, M.; Kinoshita, M.; Ashi, J.
2008-12-01
Nankai subduction zone off Kii Peninsula is one of the most intensively surveyed areas for studies on the seismogenic zone. Multichannel seismic reflection surveys carried out in this area revealed the existence of splay faults that branched from the subduction zone plate boundary [Park et al., 2002]. Along the splay faults, reversal of reflection polarity was observed, indicating elevated pore fluid pressure along the faults. Cold seepages with biological communities were discovered along a seafloor outcrop of one of the splay faults through submersible observations. Long-term temperature monitoring at a biological community site along the outcrop revealed high heat flow carried by upward fluid flow (>180 mW/m2) [Goto et al., 2003]. Toki et al. [2004] estimated upward fluid flow rates of 40-200 cm/yr from chloride distribution of interstitial water extracted from sediments in and around biological community sites along the outcrop. These observation results suggest upward fluid flow along the splay fault. In order to investigate hydrological nature of the splay fault, we conducted long-term temperature monitoring again in the same cold seepage site where Goto et al. [2003] carried out long-term temperature monitoring. In this presentation, we present results of the temperature monitoring and estimate heat flow carried by upward fluid flow from the temperature records. In this long-term temperature monitoring, we used stand-alone heat flow meter (SAHF), a probe-type sediment temperature recorder. Two SAHFs (SAHF-3 and SAHF-4) were used in this study. SAHF-4 was inserted into a bacterial mat, within several meters of which the previous long-term temperature monitoring was conducted. SAHF-3 was penetrated into ordinary sediment near the bacterial mat. The sub-bottom temperature records were obtained for 8 months. The subsurface temperatures oscillated reflecting bottom- water temperature variation (BTV). For sub-bottom temperatures measured with SAHF-3 (outside of the bacterial mat), we found that the effects of the BTV propagated into sediment by conduction only. By correcting the effect of the BTV, conductive heat flow estimated is higher than 100 mW/m2. Sub-bottom temperatures measured within bacterial mat (SAHF-4) except for the topmost sensor could be explained by a conduction model. The heat flow estimated based on the conduction model is similar to that measured with SAHF-3. The temperature of the topmost sensor is slightly higher than that expected from the conduction model. To explain the high temperature, upward fluid flow at a rate of 10-7 m/s order is needed. Heat flow carried by the upward fluid flow is higher than that estimated by Goto et al. [2003]. Heat flow value expected from the distribution of heat flow around this area is 70-80 mW/m2. The high heat flow values inside and outside the bacterial mat estimated in the present and previous studies may reflect upward fluid flow along the splay fault.
Storage Capacity Explains Fluid Intelligence but Executive Control Does Not
ERIC Educational Resources Information Center
Chuderski, Adam; Taraday, Maciej; Necka, Edward; Smolen, Tomasz
2012-01-01
We examined whether fluid intelligence (Gf) is better predicted by the storage capacity of active memory or by the effectiveness of executive control. In two psychometric studies, we measured storage capacity with three kinds of task which required the maintenance of a visual array, the monitoring of simple relations among perceptually available…
Scheidweiler, Karl B.; Himes, Sarah K.; Chen, Xiaohong; Liu, Hua-Fen
2013-01-01
Currently, Δ9-tetrahydrocannabinol (THC) is the analyte quantified for oral fluid cannabinoid monitoring. The potential for false-positive oral fluid cannabinoid results from passive exposure to THC-laden cannabis smoke raises concerns for this promising new monitoring technology. Oral fluid 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THCCOOH) is proposed as a marker of cannabis intake since it is not present in cannabis smoke and was not measureable in oral fluid collected from subjects passively exposed to cannabis. THCCOOH concentrations are in the picogram per milliliter range in oral fluid and pose considerable analytical challenges. A liquid chromatography–tandem mass spectrometry (LCMSMS) method was developed and validated for quantifying THCCOOH in 1 mL Quantisal-collected oral fluid. After solid phase extraction, chromatography was performed on a Kinetex C18 column with a gradient of 0.01 % acetic acid in water and 0.01 % acetic acid in methanol with a 0.5-mL/min flow rate. THCCOOH was monitored in negative mode electrospray ionization and multiple reaction monitoring mass spectrometry. The THCCOOH linear range was 12–1,020 pg/mL (R2>0.995). Mean extraction efficiencies and matrix effects evaluated at low and high quality control (QC) concentrations were 40.8–65.1 and −2.4–11.5 %, respectively (n=10). Analytical recoveries (bias) and total imprecision at low, mid, and high QCs were 85.0–113.3 and 6.6–8.4 % coefficient of variation, respectively (n=20). This is the first oral fluid THCCOOH LCMSMS triple quadrupole method not requiring derivatization to achieve a <15 pg/mL limit of quantification. The assay is applicable for the workplace, driving under the influence of drugs, drug treatment, and pain management testing. PMID:23681203
Vender, John; Waller, Jennifer; Dhandapani, Krishnan; McDonnell, Dennis
2011-08-01
Intracranial pressure measurements have become one of the mainstays of traumatic brain injury management. Various technologies exist to monitor intracranial pressure from a variety of locations. Transducers are usually placed to assess pressure in the brain parenchyma and the intra-ventricular fluid, which are the two most widely accepted compartmental monitoring sites. The individual reliability and inter-reliability of these devices with and without cerebrospinal fluid diversion is not clear. The predictive capability of monitors in both of these sites to local, regional, and global changes also needs further clarification. The technique of monitoring intraventricular pressure with a fluid-coupled transducer system is also reviewed. There has been little investigation into the relationship among pressure measurements obtained from these two sources using these three techniques. Eleven consecutive patients with severe, closed traumatic brain injury not requiring intracranial mass lesion evacuation were admitted into this prospective study. Each patient underwent placement of a parenchymal and intraventricular pressure monitor. The ventricular catheter tubing was also connected to a sensor for fluid-coupled measurement. Pressure from all three sources was measured hourly with and without ventricular drainage. Statistically significant correlation within each monitoring site was seen. No monitoring location was more predictive of global pressure changes or more responsive to pressure changes related to patient stimulation. However, the intraventricular pressure measurements were not reliable in the presence of cerebrospinal fluid drainage whereas the parenchymal measurements remained unaffected. Intraparenchymal pressure monitoring provides equivalent, statistically similar pressure measurements when compared to intraventricular monitors in all care and clinical settings. This is particularly valuable when uninterrupted cerebrospinal fluid drainage is desirable.
NASA Astrophysics Data System (ADS)
Trevino, S., III; Hickey, M. S.; Everett, M. E.
2017-12-01
Controlled-Source Electromagnetics (CSEM) can be used to monitor the movement and extent of injection fluid during a hydraulic fracture. The response of the fluid to energization by a CSEM source is dependent upon the electrical conductivity difference between the fluid and background geological formation. An important property that must be taken into account when modeling and interpreting CSEM responses is that electrical conductivity may be anisotropic. We study the effect of electrical anisotropy in both the background formation and the fluid-injection zone. First, various properties of the background formation can affect anisotropy including variations in grain size, composition and bedding-plane orientation. In certain formations, such as shale, the horizontal component of the conductivity can be more than an order of magnitude larger than the vertical component. We study this effect by computing differences in surface CSEM responses using the analytic 1-D anisotropic primary solution of a horizontal electric dipole positioned at the surface. Second, during hydraulic fracturing, the injected fluid can create new fractures and infill existing natural fractures. To include the explicit fracture geometry in modeling, a large increase in the number of nodes and computational time is required which may not be feasible. An alternative is to instead model the large-scale fracture geometry as a uniform slab with an appropriate bulk conductivity. Micro-scale fracture geometry may cause preferential fluid propagation in a single direction or plane which can be represented by electrical anisotropy of the slab. To study such effects of bulk anisotropy on CSEM responses we present results from multiple scenarios of surface to surface hydraulic fracture monitoring using 3-D finite element modeling. The model uses Coulomb-gauged potentials to solve Maxwell's equations in the frequency domain and we have updated the code to allow a triaxial electrical conductivity tensor to be specified. By allowing for formation and target electrical anisotropy these modeling results contribute to a better understanding and faster interpretation of field data.
Portable device and method for determining permeability characteristics of earth formations
Shuck, Lowell Z.
1977-01-01
The invention is directed to a device which is used for determining permeability characteristics of earth formations at the surface thereof. The determination of the maximum permeability direction and the magnitude of permeability are achieved by employing a device comprising a housing having a central fluid-injection port surrounded by a plurality of spaced-apart fluid flow and pressure monitoring ports radially extending from the central injection port. With the housing resting on the earth formation in a relatively fluid-tight manner as provided by an elastomeric pad disposed therebetween, fluid is injected through the central port into the earth formation and into registry with the fluid-monitoring ports disposed about the injection port. The fluid-monitoring ports are selectively opened and the flow of the fluid through the various fluid ports is measured so as to provide a measurement of flow rates and pressure distribution about the center hole which is indicative on the earth formation permeability direction and magnitude. For example, the azimuthal direction of the fluid-monitoring ports in the direction through which the greatest amount of injected fluid flows as determined by the lowest pressure distribution corresponds to the direction of maximum permeability in the earth formation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marchesini, Pierpaolo; Daley, Thomas; Ajo-Franklin, Jonathan
Monitoring of time-varying reservoir properties, such as the state of stress, is a primary goal of geophysical investigations, including for geological sequestration of CO 2, enhanced hydrocarbon recovery (EOR), and other subsurface engineering activities. In this work, we used Continuous Active-Source Seismic Monitoring (CASSM), with cross-well geometry, to measure variation in seismic coda amplitude, as a consequence of effective stress change (in the form of changes in pore fluid pressure). To our knowledge, the presented results are the first in-situ example of such crosswell measurement at reservoir scale and in field conditions. Data compliment the findings of our previous workmore » which investigated the relationship between pore fluid pressure and seismic velocity (velocity-stress sensitivity) using the CASSM system at the same field site (Marchesini et al., 2017, in review). We find that P-wave coda amplitude decreases with decreasing pore pressure (increasing effective stress).« less
Hubbell, Joel M.; Sisson, James B.
2002-01-01
The present invention relates to a monitoring well which includes an enclosure defining a cavity and a water reservoir enclosed within the cavity and wherein the reservoir has an inlet and an outlet. The monitoring well further includes a porous housing borne by the enclosure and which defines a fluid chamber which is oriented in fluid communication with the outlet of the reservoir, and wherein the porous housing is positioned in an earthen soil location below-grade. A geophysical monitoring device is provided and mounted in sensing relation relative to the fluid chamber of the porous housing; and a coupler is selectively moveable relative to the outlet of reservoir to couple the porous housing and water reservoir in fluid communication. An actuator is coupled in force transmitting relation relative to the coupler to selectively position the coupler in a location to allow fluid communication between the reservoir and the fluid chamber defined by the porous housing.
Charging Effects on Fluid Stream Droplets for Momentum Exchange Between Spacecraft
2009-01-01
DC705 have similar density; 1070 kg/m 3 for DC704 and 1097 kg/m 3 for DC705. The fluids differ chemically by a single methyl group, which is replaced...measured as a function of photon energy. The relative light intensity was monitored by the fluorescence of Sodium Salicylate . Division of the current by
NASA Astrophysics Data System (ADS)
De Siena, Luca; Sketsiou, Panayiota
2017-04-01
We plan the application of a joint velocity, attenuation, and scattering tomography to the North Sea basins. By using seismic phases and intensities from previous passive and active surveys our aim is to image and monitor fluids under the subsurface. Seismic intensities provide unique solutions to the problem of locating/tracking gas/fluid movements in the volcanoes and depicting sub-basalt and sub-intrusives in volcanic reservoirs. The proposed techniques have been tested in volcanic Islands (Deception Island), continental calderas (Campi Flegrei) and Quaternary Volcanoes (Mount. St. Helens) and have been proved effective at monitoring fracture opening, imaging buried fluid-filled bodies, and tracking water/gas interfaces. These novel seismic attributes are modelled in space and time and connected with the lithology of the sampled medium, specifically density and permeability, with as key output a novel computational code with strong commercial potential. Data are readily available in the framework of the NERC CDT Oil & Gas project.
ESTIMATION OF FREE HYDROCARBON VOLUME FROM FLUID LEVELS IN MONITORING WELLS
Under the assumption of local vertical equilibrium, fluid pressure distributions specified from well fluid levels in monitoring wells may be used to predict water and hydrocarbon saturation profiles given expressions for air-water-hydrocarbon saturation-pressure relations. Verti...
Chaves, Esteban J; Schwartz, Susan Y
2016-01-01
In subduction zones, elevated pore fluid pressure, generally linked to metamorphic dehydration reactions, has a profound influence on the mechanical behavior of the plate interface and forearc crust through its control on effective stress. We use seismic noise-based monitoring to characterize seismic velocity variations following the 2012 Nicoya Peninsula, Costa Rica earthquake [M w (moment magnitude) 7.6] that we attribute to the presence of pressurized pore fluids. Our study reveals a strong velocity reduction (~0.6%) in a region where previous work identified high forearc pore fluid pressure. The depth of this velocity reduction is constrained to be below 5 km and therefore not the result of near-surface damage due to strong ground motions; rather, we posit that it is caused by fracturing of the fluid-pressurized weakened crust due to dynamic stresses. Although pressurized fluids have been implicated in causing coseismic velocity reductions beneath the Japanese volcanic arc, this is the first report of a similar phenomenon in a subduction zone setting. It demonstrates the potential to identify pressurized fluids in subduction zones using temporal variations of seismic velocity inferred from ambient seismic noise correlations.
Perfluorocarbon Tracers (PFTs) Complement stable Isotopes and Geochemistry for Verifying, Assessing or Modeling Fluid Flow. Geochemistry, Isotopes and PFT’s complement Geophysics to monitor and verify plume movement, leakage to shallow aquifers or surface
NASA Astrophysics Data System (ADS)
David, C.; Dautriat, J. D.; Sarout, J.; Macault, R.; Bertauld, D.
2014-12-01
Water weakening is a well-known phenomenon which can lead to subsidence during the production of hydrocarbon reservoirs. The example of the Ekofisk oil field in the North Sea has been well documented for years. In order to assess water weakening effects in reservoir rocks, previous studies have focused on changes in the failure envelopes derived from mechanical tests conducted on rocks saturated either with water or with inert fluids. However, little attention has been paid so far on the mechanical behaviour during the fluid injection stage, like in enhanced oil recovery operations. We studied the effect of fluid injection on the mechanical behaviour of Sherwood sandstone, a weakly-consolidated sandstone sampled at Ladram Bay in UK. In order to highlight possible weakening effects, water and inert oil have been injected into critically-loaded samples to assess their effect on strength and elastic properties and to derive the acoustic signature of the saturation front for each fluid. The specimens were instrumented with 16 ultrasonic P-wave transducers for both passive and active acoustic monitoring during fluid injection and loading. After conducting standard triaxial tests on three samples saturated with air, water and oil respectively, mechanical creep tests were conducted on dry samples loaded at 80% of the compressive strength of the dry rock. While these conditions are kept constant, a fluid is injected at the bottom end of the sample with a low back pressure (0.5 MPa) to minimize effective stress variations during injection. Both water and oil were used as the injected pore fluid in two experiments. As soon as the fluids start to flow into the samples, creep is taking place with a much higher strain rate for water injection compared to oil injection. A transition from secondary creep to tertiary creep is observed in the water injection test whereas in the oil injection test no significant creep acceleration is observed after one pore volume of oil was injected. The most remarkable difference is that water injection induces mechanical instability and failure, whereas oil injection does not. This was confirmed by the analysis of acoustic emissions activity and post-mortem sample imaging using CT scan. Contrasting evolutions of the P wave velocity during the fluid front propagation were also observed in both experiments.
Siddiqui, Muhammad Rafay Sameen; Sajid, Muhammad Shafiq; Baig, Mirza Khurram
2009-04-01
The advancement of medical technology and future improvements in public health will lead to surgeons operating on high risk patients. One of these advances is to use intra-operative trans-oesophageal Doppler (TOD) to optimise fluid management. TOD is known to be the most effective technique for intraoperative cardiac monitoring. We report a case of a potentially life threatening complication from intraoperative TOD monitoring.
Welch, Janet; Dowell, Shannon; Johnson, Cynthia S
2007-01-01
The feasibility of using an electronic device to self-monitor diet and fluid intake was assessed using the treatment implementation model. The three patients on hemodialysis who participated in this pilot study were asked to self-monitor diet and fluid intake for 12 weeks with a personal digital assistant. The intervention was delivered as intended; however, participants reported problems with usability, and compliance to self-monitoring was lower than desirable. Further adjustments to the intervention will be made before testing efficacy.
Oral fluid vs. Urine Analysis to Monitor Synthetic Cannabinoids and Classic Drugs Recent Exposure
Blandino, Vincent; Wetzel, Jillian; Kim, Jiyoung; Haxhi, Petrit; Curtis, Richard; Concheiro, Marta
2018-01-01
Background Urine is a common biological sample to monitor recent drug exposure, and oral fluid is an alternative matrix of increasing interest in clinical and forensic toxicology. Limited data are available about oral fluid vs. urine drug disposition, especially for synthetic cannabinoids. Objective To compare urine and oral fluid as biological matrices to monitor recent drug exposure among HIV-infected homeless individuals. Methods Seventy matched urine and oral fluid samples were collected from 13 participants. Cannabis, amphetamines, benzodiazepines, cocaine and opiates were analyzed in urine by the enzyme-multiplied-immunoassay-technique and in oral fluid by liquid chromatography tandem mass spectrometry (LC-MSMS). Eleven synthetic cannabinoids were analyzed in urine and in oral fluid by LC-MSMS. Results Five oral fluid samples were positive for AB-FUBINACA. In urine, 4 samples tested positive for synthetic cannabinoids PB-22, 5-Fluoro-PB-22, AB-FUBINACA, and metabolites UR-144 5-pentanoic acid and UR-144 4-hydroxypentyl. In only one case, oral fluid and urine results matched, both specimens being AB-FUBINACA positive. For cannabis, 40 samples tested positive in urine and 30 in oral fluid (85.7% match). For cocaine, 37 urine and 52 oral fluid samples were positive (75.7% match). Twenty-four urine samples were positive for opiates, and 25 in oral fluid (81.4% match). For benzodiazepines, 23 samples were positive in urine and 25 in oral fluid (85.7% match). Conclusion/Discussion These results offer new information about drugs disposition between urine and oral fluid. Oral fluid is a good alternative matrix to urine for monitoring cannabis, cocaine, opiates and benzodiazepines recent use; however, synthetic cannabinoids showed mixed results. PMID:29173162
Oral Fluid vs. Urine Analysis to Monitor Synthetic Cannabinoids and Classic Drugs Recent Exposure.
Blandino, Vincent; Wetzel, Jillian; Kim, Jiyoung; Haxhi, Petrit; Curtis, Richard; Concheiro, Marta
2017-01-01
Urine is a common biological sample to monitor recent drug exposure, and oral fluid is an alternative matrix of increasing interest in clinical and forensic toxicology. Limited data are available about oral fluid vs. urine drug disposition, especially for synthetic cannabinoids. To compare urine and oral fluid as biological matrices to monitor recent drug exposure among HIV-infected homeless individuals. Seventy matched urine and oral fluid samples were collected from 13 participants. Cannabis, amphetamines, benzodiazepines, cocaine and opiates were analyzed in urine by the enzyme-multipliedimmunoassay- technique and in oral fluid by liquid chromatography tandem mass spectrometry (LCMSMS). Eleven synthetic cannabinoids were analyzed in urine and in oral fluid by LC-MSMS. Five oral fluid samples were positive for AB-FUBINACA. In urine, 4 samples tested positive for synthetic cannabinoids PB-22, 5-Fluoro-PB-22, AB-FUBINACA, and metabolites UR-144 5-pentanoic acid and UR-144 4-hydroxypentyl. In only one case, oral fluid and urine results matched, both specimens being AB-FUBINACA positive. For cannabis, 40 samples tested positive in urine and 30 in oral fluid (85.7% match). For cocaine, 37 urine and 52 oral fluid samples were positive (75.7% match). Twenty-four urine samples were positive for opiates, and 25 in oral fluid (81.4% match). For benzodiazepines, 23 samples were positive in urine and 25 in oral fluid (85.7% match). These results offer new information about drugs disposition between urine and oral fluid. Oral fluid is a good alternative matrix to urine for monitoring cannabis, cocaine, opiates and benzodiazepines recent use; however, synthetic cannabinoids showed mixed results. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Weitz, Karl K [Pasco, WA; Moore, Ronald J [West Richland, WA
2010-07-13
A method and device are disclosed that provide for detection of fluid leaks in analytical instruments and instrument systems. The leak detection device includes a collection tube, a fluid absorbing material, and a circuit that electrically couples to an indicator device. When assembled, the leak detection device detects and monitors for fluid leaks, providing a preselected response in conjunction with the indicator device when contacted by a fluid.
Sato, Takashi; Taoka, Masahiro; Miyahara, Takaaki
2011-01-01
In Japan, acetate-free biofiltration (AFBF) became commercially available in the year 2000, and these products have been reported to be clinically effective for controlling the decrease of blood pressure during dialysis or various types of dialysis intolerance. And more, acetate-free dialysis fluid was made clinically available in 2007, acetate-free hemodialysis (AFHD) is expected to inhibit the malnutrition-inflammation-atherosclerosis syndrome, improve anemia and the nutritional status of patients, stabilize hemodynamics, and reduce inflammation and oxidative stress. In a broad sense, AFBF can be classified as hemodiafiltration (HDF), and its clinical effects seem to be associated with multiple factors, including use of acetate-free dialysis fluid, massive removal of low molecular weight proteins by convection, and the sodium concentration of the replacement fluid. Therefore, the clinical significance of acetate-free dialysis fluid could be demonstrated more clearly by comparing AFHD with conventional hemodialysis (conv. HD) using dialysis fluid containing about 10 mEq/l acetate. Since 2005, we have been investigating the efficacy of various modalities of blood purification therapy by continuously monitoring changes of tissue blood flow in the lower limbs and earlobes (head) using non-invasive continuous monitoring method (NICOMM). In this report, we assess the clinical effectiveness of AFHD on the basis of clinical findings and head stability index (head SI) obtained by NICOMM, particularly with respect to the influence on autonomic regulation. After switching to AFHD from conv. HD, anemia, stored iron utilization, and the frequency of treatments for dialysis hypotension and of muscle cramps were significantly improved. Further, the head SI was also significantly smaller with AFHD than conv. HD. This finding suggests that AFHD improved the maintenance of homeostasis by the autonomic nervous regulation system. In addition, we could not find clinical features of excessive alkalosis during an observation period of about 1 year, even if online HDF using acetate-free dialysis fluid as the substitution fluid. Our conclusion is that the advent of acetate-free dialysis fluid has led to investigations into new clinical effectiveness of AFHD or online HDF/HF using ultrapurified acetate-free dialysis fluid as the substitution fluid. Copyright © 2011 S. Karger AG, Basel.
Sensing of fluid viscoelasticity from piezoelectric actuation of cantilever flexural vibration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, Jeongwon; Jeong, Seongbin; Kim, Seung Joon
2015-01-15
An experimental method is proposed to measure the rheological properties of fluids. The effects of fluids on the vibration actuated by piezoelectric patches were analyzed and used in measuring viscoelastic properties. Fluid-structure interactions induced changes in the beam vibration properties and frequency-dependent variations of the complex wavenumber of the beam structure were used in monitoring these changes. To account for the effects of fluid-structure interaction, fluids were modelled as a simple viscoelastic support at one end of the beam. The measured properties were the fluid’s dynamic shear modulus and loss tangent. Using the proposed method, the rheological properties of variousmore » non-Newtonian fluids were measured. The frequency range for which reliable viscoelasticity results could be obtained was 10–400 Hz. Viscosity standard fluids were tested to verify the accuracy of the proposed method, and the results agreed well with the manufacturer’s reported values. The simple proposed laboratory setup for measurements was flexible so that the frequency ranges of data acquisition were adjustable by changing the beam’s mechanical properties.« less
[Fluid therapy in acute pancreatitis].
de-Madaria, Enrique
2013-12-01
Severe acute pancreatitis (AP) is associated with an increased need for fluids due to fluid sequestration and, in the most severe cases, with decreased peripheral vascular tone. For several decades, clinical practice guidelines have recommended aggressive fluid therapy to improve the prognosis of AP. This recommendation is based on theoretical models, animal studies, and retrospective studies in humans. Recent studies suggest that aggressive fluid administration in all patients with AP could have a neutral or harmful effect. Fluid therapy based on Ringer's lactate could improve the course of the disease, although further studies are needed to confirm this possibility. Most patients with AP do not require invasive monitoring of hemodynamic parameters to guide fluid therapy administration. Moreover, the ability of these parameters to improve prognosis has not been demonstrated. Copyright © 2013 Elsevier España, S.L. and AEEH y AEG. All rights reserved.
An inexpensive open-source ultrasonic sensing system for monitoring fluid levels
USDA-ARS?s Scientific Manuscript database
Fluid levels are measured in a variety of agricultural applications, and are often measured manually, which can be time-consuming and labor-intensive. Rapid advances in electronic technologies have made a variety of inexpensive sensing, monitoring, and control capabilities available. A monitoring ...
Wright, Karen D; Panetta, John C; Onar-Thomas, Arzu; Reddick, Wilburn E; Patay, Zoltan; Qaddoumi, Ibrahim; Broniscer, Alberto; Robinson, Giles; Boop, Frederick A; Klimo, Paul; Ward, Deborah; Gajjar, Amar; Stewart, Clinton F
2015-01-01
High-dose methotrexate (HD-MTX) has been used to treat children with central nervous system tumors. Accumulation of MTX within pleural, peritoneal, or cardiac effusions has led to delayed excretion and increased risk of systemic toxicity. This retrospective study analyzed the association of intracranial post-resection fluid collections with MTX plasma disposition in infants and young children with brain tumors. Brain MRI findings were analyzed for postoperative intracranial fluid collections in 75 pediatric patients treated with HD-MTX and for whom serial MTX plasma concentrations (MTX) were collected. Delayed plasma excretion was defined as (MTX) ≥1 μM at 42 hours (h). Leucovorin was administered at 42 h and then every 6 h until (MTX) <0.1 μM. Population and individual MTX pharmacokinetic parameters were estimated by nonlinear mixed-effects modeling. Fifty-eight patients had intracranial fluid collections present. Population average (inter-individual variation) MTX clearance was 96.0 ml/min/m² (41.1 CV %) and increased with age. Of the patients with intracranial fluid collections, 24 had delayed excretion; only 2 of the 17 without fluid collections (P < 0.04) had delayed excretion. Eleven patients had grade 3 or 4 toxicities attributed to HD-MTX. No significant difference was observed in intracranial fluid collection, total leucovorin dosing, or hydration fluids between those with and without toxicity. Although an intracranial fluid collection is associated with delayed MTX excretion, HD-MTX can be safely administered with monitoring of infants and young children with intracranial fluid collections. Infants younger than 1 year may need additional monitoring to avoid toxicity.
Brinkmalm, Ann; Brinkmalm, Gunnar; Honer, William G; Frölich, Lutz; Hausner, Lucrezia; Minthon, Lennart; Hansson, Oskar; Wallin, Anders; Zetterberg, Henrik; Blennow, Kaj; Öhrfelt, Annika
2014-11-23
Synaptic degeneration is an early pathogenic event in Alzheimer's disease, associated with cognitive impairment and disease progression. Cerebrospinal fluid biomarkers reflecting synaptic integrity would be highly valuable tools to monitor synaptic degeneration directly in patients. We previously showed that synaptic proteins such as synaptotagmin and synaptosomal-associated protein 25 (SNAP-25) could be detected in pooled samples of cerebrospinal fluid, however these assays were not sensitive enough for individual samples. We report a new strategy to study synaptic pathology by using affinity purification and mass spectrometry to measure the levels of the presynaptic protein SNAP-25 in cerebrospinal fluid. By applying this novel affinity mass spectrometry strategy on three separate cohorts of patients, the value of SNAP-25 as a cerebrospinal fluid biomarker for synaptic integrity in Alzheimer's disease was assessed for the first time. We found significantly higher levels of cerebrospinal fluid SNAP-25 fragments in Alzheimer's disease, even in the very early stages, in three separate cohorts. Cerebrospinal fluid SNAP-25 differentiated Alzheimer's disease from controls with area under the curve of 0.901 (P < 0.0001). We developed a sensitive method to analyze SNAP-25 levels in individual CSF samples that to our knowledge was not possible previously. Our results support the notion that synaptic biomarkers may be important tools for early diagnosis, assessment of disease progression, and to monitor drug effects in treatment trials.
A New Frontier for Cardiac Monitoring
NASA Technical Reports Server (NTRS)
2001-01-01
CardioDynamics International Corporation (CDIC) has created the BioZ(TM) System through a Small Business Innovation Research (SBIR) award from Johnson Space Center, providing patients and physicians with a cost-effective and highly accurate monitoring system.The BioZ non-invasive heart monitor is based on a technology known as Impedance Cardiography (ICG). BioZ provides the physician with vital information about the heart's ability to deliver blood to the body, the force one's heart exerts with each beat, and the amount of fluid in the chest. Specially designed bioimpedance sensors placed on the neck and chest monitor 12 different parameters, including cardiac output, contractility, systemic vascular resistance, and thoracic fluid content. These sensors monitor the electrical conductivity of the body-information that is converted into blood flow data and is displayed in real time on a monitoring screen. BioZ.com(TM) and BioZ.pc(TM) are two additional products that incorporate the same sensors present in the original BioZ system. The "com" in BioZ.com stands for cardiac output monitor. This fully integrated system is essentially a smaller version of the BioZ, combining the same abilities with a compact, lightweight design, while providing greater portability.
Real-time monitoring of moisture levels in wound dressings in vitro: an experimental study.
McColl, David; Cartlidge, Brian; Connolly, Patricia
2007-10-01
Retaining an appropriate level of moisture at the interface between a healing wound and an applied dressing is considered to be critical for effective wound healing. Failure to control exudate at this interface can result in maceration or drying out of the wound surface. The ability to control moisture balance at the wound interface is therefore a key aspect of wound dressing performance. To date it has not been possible to monitor in any effective manner the distribution of moisture within dressings or how this varies with time. A new measurement system is presented based on sensors placed at the wound/dressing interface which are capable of monitoring moisture levels in real time. The system comprises a model wound bed and sensor array complete with fluid injection path to mimic exudate flow. Eight monitoring points, situated beneath the test dressing, allow the moisture profile across the complete dressing to be measured both during and after fluid injection. The system has been used to evaluate the performance of four foam dressings, a composite hydrofibre dressing and a film dressing. Stark contrasts in the performance of the wound contact layer were found between the different wound dressing types. The composite hydrofibre dressing retained moisture at the wound interface throughout the experiments while areas of the foam dressing quickly became dry, even during constant injection of fluid. The abundance of sensors allowed a moisture map of the surface of the wound dressing to be constructed, illustrating that the moisture profile was not uniform across several of the dressings tested during absorption and evaporation of liquid. These results raise questions as to how the dressings behave on a wound in vivo and indicate the need for a similar clinical monitoring system for tracking wound moisture levels.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marchesini, P; Ajo-Franklin, JB; Daley, TM
2017-09-01
© 2017 Society of Exploration Geophysicists. The ability to characterize time-varying reservoir properties, such as the state of stress, has fundamental implications in subsurface engineering, relevant to geologic sequestration of CO2. Stress variation, here in the form of changes in pore fluid pressure, is one factor known to affect seismic velocity. Induced variations in velocity have been used in seismic studies to determine and monitor changes in the stress state. Previous studies conducted to determine velocity-stress sensitivity at reservoir conditions rely primarily on laboratory measurements of core samples or theoretical relationships. We have developed a novel field-scale experiment designed tomore » study the in situ relationship between pore-fluid pressure and seismic velocity using a crosswell continuous active-source seismic monitoring (CASSM) system. At the Cranfield, Mississippi, CO2 sequestration field site, we actively monitored seismic response for five days with a temporal resolution of 5 min; the target was a 26 m thick injection zone at approximately 3.2 km depth in a fluvial sandstone formation (lower Tuscaloosa Formation). The variation of pore fluid pressure was obtained during discrete events of fluid withdrawal from one of the two wells and monitored with downhole pressure sensors. The results indicate a correlation between decreasing CASSM time delay (i.e., velocity change for a raypath in the reservoir) and periods of reduced fluid pore pressure. The correlation is interpreted as the velocity-stress sensitivity measured in the reservoir. This observation is consistent with published laboratory studies documenting a velocity (V) increase with an effective stress increase. A traveltime change (dt) of 0.036 ms is measured as the consequence of a change in pressure of approximately 2.55 MPa (dPe). For T 1/4 13 ms total traveltime, the velocity-stress sensitivity is dV/V/dPe 1/4 dt/T/dPe 1/4 10.9 × 10-4/MPa. The overall results suggest that CASSM measurements represent a valid technique for in situ determination of velocity-stress sensitivity in field-scale monitoring studies.« less
A distributed fluid level sensor suitable for monitoring fuel load on board a moving fuel tank
NASA Astrophysics Data System (ADS)
Arkwright, John W.; Parkinson, Luke A.; Papageorgiou, Anthony W.
2018-02-01
A temperature insensitive fiber Bragg grating sensing array has been developed for monitoring fluid levels in a moving tank. The sensors are formed from two optical fibers twisted together to form a double helix with pairs of fiber Bragg gratings located above one another at the points where the fibers are vertically disposed. The sensing mechanism is based on a downwards deflection of the section of the double helix containing the FBGs which causes the tension in the upper FBG to decrease and the tension in the lower FBG to increase with concomitant changes in Bragg wavelength in each FBG. Changes in ambient temperature cause a common mode increase in Bragg wavelength, thus monitoring the differential change in wavelength provides a temperature independent measure of the applied pressure. Ambient temperature can be monitored simultaneously by taking the average wavelength of the upper and lower FBGs. The sensors are able to detect variations in pressure with resolutions better than 1 mmH2O and when placed on the bottom of a tank can be used to monitor fluid level based on the recorded pressure. Using an array of these sensors located along the bottom of a moving tank it was possible to monitor the fluid level at multiple points and hence dynamically track the total fluid volume in the tank. The outer surface of the sensing array is formed from a thin continuous Teflon sleeve, making it suitable for monitoring the level of volatile fluids such as aviation fuel and gasoline.
Monitoring Global Geophysical Fluids by Space Geodesy
NASA Technical Reports Server (NTRS)
Chao, Benjamin F.; Dehant, V.; Gross, R. S.; Ray, R. D.; Salstein, D. A.; Watkins, M.
1999-01-01
Since its establishment on 1/1/1998 by the International Earth Rotation Service, the Coordinating Center for Monitoring Global Geophysical Fluids (MGGF) and its seven Special Bureaus have engaged in an effort to support and facilitate the understanding of the geophysical fluids in global geodynamics research. Mass transports in the atmosphere-hydrosphere-solid Earth-core system (the "global geophysical fluids") will cause the following geodynamic effects on a broad time scale: (1) variations in the solid Earth's rotation (in length-of-day and polar motion/nutation) via the conservation of angular momentum and effected by torques at the fluid-solid Earth interface; (2) changes in the global gravitational field according to Newton's gravitational law; and (3) motion in the center of mass of the solid Earth relative to that of the whole Earth ("geocenter") via the conservation of linear momentum. These minute signals have become observable by space geodetic techniques, primarily VLBI, SLR, GPS, and DORIS, with ever increasing precision/accuracy and temporal/spatial resolution. Each of the seven Special Bureaus within MGGF is responsible for calculations related to a specific Earth component or aspect -- Atmosphere, Ocean, Hydrology, Ocean Tides, Mantle, Core, and Gravity/Geocenter. Angular momenta and torques, gravitational coefficients, and geocenter shift will be computed for geophysical fluids based on global observational data, and from state-of-the-art models, some of which assimilate such data. The computed quantities, algorithm and data formats are standardized. The results are archived and made available to the scientific research community. This paper reports the status of the MGGF activities and current results.
In-line monitoring of (MR) fluid properties
NASA Astrophysics Data System (ADS)
Kordonski, William; Gorodkin, Sergei; Behlok, Ray
2015-05-01
Proper functionality of devices and processes based on (MR) fluids greatly depends, along with other factors, on stability of fluid characteristics such as concentration of magnetic particles and magnetic properties of the particles. The concentration of magnetic particles may change due to evaporation or leakage of carrier fluid, as well as particle sedimentation. Magnetic properties may change due to temperature, corrosion of particles or irreversible aggregation. In-line noninvasive monitoring of particle concentration and magnetic properties allows, in one way or another, compensation for the impact of destabilizing factors and provides system stable output. Two novel methods of in-line measurement of MR fluid magnetic permeability or magnetic particle concentration are considered in this presentation. The first one is based on the principle of mutual inductance and is intended for monitoring MR fluid flowing in pipes or channels. In the second one, permeability is measured by a flash-mount sensor which reacts on changes in the reluctance of the MR fluid layer adjacent to the wall. The use of the methods for stabilization of the material removal rate in high precision finishing process employing aqueous MR fluid is discussed.
Digestive proteases of the lugworm (Arenicola marina) inhibited by Cu from contaminated sediments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Z.; Mayer, L.M.
1998-03-01
The authors examined potential toxic effects of copper released from contaminated sediments during deposit feeding of the lugworm, Arenicola marina. Titration of Cu solution into gut fluids can result in decreases in protease activity if sufficient Cu is added. The effects of Cu on gut proteases were confirmed by incubation of gut fluids with Cu-contaminated harbor sediments. Monitoring of Cu titration into gut fluids shows that enzyme inhibition and quenching of gut protein fluorescence occur only when sufficient Cu has been added to allow inorganic Cu species to become abundant. This threshold level probably represents the exhaustion of strong bindingmore » sites that act as protection against enzyme inhibition. Thus, sediments contaminated with Cu may have inhibitory effects on digestive processes in lugworms.« less
Mielnicki, Wojciech; Dyla, Agnieszka; Zawada, Tomasz
2016-12-05
Transthoracic echocardiography (TTE) has become one of the most important diagnostic tools in the treatment of critically ill patients. It allows clinicians to recognise potentially reversible life-threatening situations and is also very effective in the monitoring of the fluid status of patients, slowly substituting invasive methods in the intensive care unit. Hemodynamic assessment is based on a few static and dynamic parameters. Dynamic parameters change during the respiratory cycle in mechanical ventilation and the level of this change directly corresponds to fluid responsiveness. Most of the parameters cannot be used in spontaneously breathing patients. For these patients the most important test is passive leg raising, which is a good substitute for fluid bolus. Although TTE is very useful in the critical care setting, we should not forget the important limitations, not only technical ones but also caused by the critical illness itself. Unfortunately, this method does not allow continuous monitoring and every change in the patient's condition requires repeated examination.
30 CFR 250.457 - What equipment is required to monitor drilling fluids?
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 2 2014-07-01 2014-07-01 false What equipment is required to monitor drilling..., DEPARTMENT OF THE INTERIOR OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Oil and Gas Drilling Operations Drilling Fluid Requirements § 250.457 What equipment is required to monitor...
30 CFR 250.457 - What equipment is required to monitor drilling fluids?
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 2 2012-07-01 2012-07-01 false What equipment is required to monitor drilling..., DEPARTMENT OF THE INTERIOR OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Oil and Gas Drilling Operations Drilling Fluid Requirements § 250.457 What equipment is required to monitor...
30 CFR 250.457 - What equipment is required to monitor drilling fluids?
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 2 2013-07-01 2013-07-01 false What equipment is required to monitor drilling..., DEPARTMENT OF THE INTERIOR OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Oil and Gas Drilling Operations Drilling Fluid Requirements § 250.457 What equipment is required to monitor...
Jin, Kui; Murugan, Raghavan; Sileanu, Florentina E; Foldes, Emily; Priyanka, Priyanka; Clermont, Gilles; Kellum, John A
2017-11-01
Urine output (UO) is a vital sign for critically ill patients, but standards for monitoring and reporting vary widely between ICUs. Careful monitoring of UO could lead to earlier recognition of acute kidney injury (AKI) and better fluid management. We sought to determine if the intensity of UO monitoring is associated with outcomes in patients with and those without AKI. This was a retrospective cohort study including 15,724 adults admitted to ICUs from 2000 to 2008. Intensive UO monitoring was defined as hourly recordings and no gaps > 3 hours for the first 48 hours after ICU admission. Intensive monitoring for UO was conducted in 4,049 patients (26%), and we found significantly higher rates of AKI (OR, 1.22; P < .001) in these patients. After adjustment for age and severity of illness, intensive UO monitoring was associated with improved survival but only among patients experiencing AKI. With or without AKI, patients with intensive monitoring also had less cumulative fluid volume (2.98 L vs 3.78 L; P < .001) and less fluid overload (2.49% vs 5.68%; P < .001) over the first 72 hours of ICU stay. In this large ICU population, intensive monitoring of UO was associated with improved detection of AKI and reduced 30-day mortality in patients experiencing AKI, as well as less fluid overload for all patients. Our results should help inform clinical decisions and ICU policy about frequency of monitoring of UO, especially for patients at high risk of AKI or fluid overload, or both. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
Technological advances in perioperative monitoring: Current concepts and clinical perspectives
Chilkoti, Geetanjali; Wadhwa, Rachna; Saxena, Ashok Kumar
2015-01-01
Minimal mandatory monitoring in the perioperative period recommended by Association of Anesthetists of Great Britain and Ireland and American Society of Anesthesiologists are universally acknowledged and has become an integral part of the anesthesia practice. The technologies in perioperative monitoring have advanced, and the availability and clinical applications have multiplied exponentially. Newer monitoring techniques include depth of anesthesia monitoring, goal-directed fluid therapy, transesophageal echocardiography, advanced neurological monitoring, improved alarm system and technological advancement in objective pain assessment. Various factors that need to be considered with the use of improved monitoring techniques are their validation data, patient outcome, safety profile, cost-effectiveness, awareness of the possible adverse events, knowledge of technical principle and ability of the convenient routine handling. In this review, we will discuss the new monitoring techniques in anesthesia, their advantages, deficiencies, limitations, their comparison to the conventional methods and their effect on patient outcome, if any. PMID:25788767
Technological advances in perioperative monitoring: Current concepts and clinical perspectives.
Chilkoti, Geetanjali; Wadhwa, Rachna; Saxena, Ashok Kumar
2015-01-01
Minimal mandatory monitoring in the perioperative period recommended by Association of Anesthetists of Great Britain and Ireland and American Society of Anesthesiologists are universally acknowledged and has become an integral part of the anesthesia practice. The technologies in perioperative monitoring have advanced, and the availability and clinical applications have multiplied exponentially. Newer monitoring techniques include depth of anesthesia monitoring, goal-directed fluid therapy, transesophageal echocardiography, advanced neurological monitoring, improved alarm system and technological advancement in objective pain assessment. Various factors that need to be considered with the use of improved monitoring techniques are their validation data, patient outcome, safety profile, cost-effectiveness, awareness of the possible adverse events, knowledge of technical principle and ability of the convenient routine handling. In this review, we will discuss the new monitoring techniques in anesthesia, their advantages, deficiencies, limitations, their comparison to the conventional methods and their effect on patient outcome, if any.
NASA Astrophysics Data System (ADS)
Scuderi, M. M.; Collettini, C.; Marone, C.
2017-11-01
It is widely recognized that the significant increase of M > 3.0 earthquakes in Western Canada and the Central United States is related to underground fluid injection. Following injection, fluid overpressure lubricates the fault and reduces the effective normal stress that holds the fault in place, promoting slip. Although, this basic physical mechanism for earthquake triggering and fault slip is well understood, there are many open questions related to induced seismicity. Models of earthquake nucleation based on rate- and state-friction predict that fluid overpressure should stabilize fault slip rather than trigger earthquakes. To address this controversy, we conducted laboratory creep experiments to monitor fault slip evolution at constant shear stress while the effective normal stress was systematically reduced via increasing fluid pressure. We sheared layers of carbonate-bearing fault gouge in a double direct shear configuration within a true-triaxial pressure vessel. We show that fault slip evolution is controlled by the stress state acting on the fault and that fluid pressurization can trigger dynamic instability even in cases of rate strengthening friction, which should favor aseismic creep. During fluid pressurization, when shear and effective normal stresses reach the failure condition, accelerated creep occurs in association with fault dilation; further pressurization leads to an exponential acceleration with fault compaction and slip localization. Our work indicates that fault weakening induced by fluid pressurization can overcome rate strengthening friction resulting in fast acceleration and earthquake slip. Our work points to modifications of the standard model for earthquake nucleation to account for the effect of fluid overpressure and to accurately predict the seismic risk associated with fluid injection.
Briggs, Martin A.; Day-Lewis, Frederick D.; Ong, John B.; Curtis, Gary P.; Lane, John W.
2013-01-01
Anomalous solute transport, modeled as rate-limited mass transfer, has an observable geoelectrical signature that can be exploited to infer the controlling parameters. Previous experiments indicate the combination of time-lapse geoelectrical and fluid conductivity measurements collected during ionic tracer experiments provides valuable insight into the exchange of solute between mobile and immobile porosity. Here, we use geoelectrical measurements to monitor tracer experiments at a former uranium mill tailings site in Naturita, Colorado. We use nonlinear regression to calibrate dual-domain mass transfer solute-transport models to field data. This method differs from previous approaches by calibrating the model simultaneously to observed fluid conductivity and geoelectrical tracer signals using two parameter scales: effective parameters for the flow path upgradient of the monitoring point and the parameters local to the monitoring point. We use regression statistics to rigorously evaluate the information content and sensitivity of fluid conductivity and geophysical data, demonstrating multiple scales of mass transfer parameters can simultaneously be estimated. Our results show, for the first time, field-scale spatial variability of mass transfer parameters (i.e., exchange-rate coefficient, porosity) between local and upgradient effective parameters; hence our approach provides insight into spatial variability and scaling behavior. Additional synthetic modeling is used to evaluate the scope of applicability of our approach, indicating greater range than earlier work using temporal moments and a Lagrangian-based Damköhler number. The introduced Eulerian-based Damköhler is useful for estimating tracer injection duration needed to evaluate mass transfer exchange rates that range over several orders of magnitude.
NASA Astrophysics Data System (ADS)
Jia, Yali; Bagnaninchi, Pierre O.; Wang, Ruikang K.
2008-02-01
Mechanical stimuli can be introduced to three dimensional (3D) cell cultures by use of perfusion bioreactor. Especially in musculoskeletal tissues, shear stress caused by fluid flow generally increase extra-cellular matrix (ECM) production and cell proliferation. The relationship between the shear stress and the tissue development in situ is complicated because of the non-uniform pore distribution within the cell-seeded scaffold. In this study, we firstly demonstrated that Doppler optical coherence tomography (DOCT) is capable of monitoring localized fluid flow and shear stress in the complex porous scaffold by examining their variation trends at perfusion rate of 5, 8, 10 and 12 ml/hr. Then, we developed the 3D porous cellular constructs, cell-seeded chitosan scaffolds monitored during several days by DOCT. The fiber based fourier domain DOCT employed a 1300 nm superluminescent diode with a bandwidth of 52 nm and a xyz resolution of 20×20×15 μm in free space. This setup allowed us not only to assess the cell growth and ECM deposition by observing their different scattering behaviors but also to further investigate how the cell attachment and ECM production has the effect on the flow shear stress and the relationship between flow rate and shear stress in the developing tissue construct. The possibility to monitor continuously the constructs under perfusion will easily indicate the effect of flow rate or shear stress on the cell viability and cell proliferation, and then discriminate the perfusion parameters affecting the pre-tissue formation rate growth.
A programmable point-of-care device for external CSF drainage and monitoring.
Simkins, Jeffrey R; Subbian, Vignesh; Beyette, Fred R
2014-01-01
This paper presents a prototype of a programmable cerebrospinal fluid (CSF) external drainage system that can accurately measure the dispensed fluid volume. It is based on using a miniature spectrophotometer to collect color data to inform drain rate and pressure monitoring. The prototype was machined with 1 μm dimensional accuracy. The current device can reliably monitor the total accumulated fluid volume, the drain rate, the programmed pressure, and the pressure read from the sensor. Device requirements, fabrication processes, and preliminary results with an experimental set-up are also presented.
Causes of death after fluid bolus resuscitation: new insights from FEAST.
Myburgh, John; Finfer, Simon
2013-03-14
The Fluid Expansion as Supportive Therapy (FEAST study) was an extremely well conducted study that gave unexpected results. The investigators had reported that febrile children with impaired perfusion treated in low-income countries without access to intensive care are more likely to die if they receive bolus resuscitation with albumin or saline compared with no bolus resuscitation at all. In a secondary analysis of the trial, published in BMC Medicine, the authors found that increased mortality was evident in patients who presented with clinical features of severe shock in isolation or in conjunction with features of respiratory or neurological failure. The cause of excess deaths was primarily refractory shock and not fluid overload. These features are consistent with a potential cardiotoxic or ischemia-reperfusion injury following resuscitation with boluses of intravenous fluid. Although these effects may have been amplified by the absence of invasive monitoring, mechanical ventilation or vasopressors, the results provide compelling insights into the effects of intravenous fluid resuscitation and potential adverse effects that extend beyond the initial resuscitation period. These data add to the increasing body of literature about the safety and efficacy of intravenous resuscitation fluids, which may be applicable to management of other populations of critically ill patients.
Hubbell, Joel M.; Sisson, James B.
1999-01-01
A monitoring well including a conduit defining a passageway, the conduit having a proximal and opposite, distal end; a coupler connected in fluid flowing relationship with the passageway; and a porous housing borne by the coupler and connected in fluid flowing relation thereto.
21 CFR 880.2460 - Electrically powered spinal fluid pressure monitor.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Electrically powered spinal fluid pressure monitor. 880.2460 Section 880.2460 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL HOSPITAL AND PERSONAL USE DEVICES General Hospital and Personal Use Monitoring Devices § 880.2460...
Wearable nanosensor system for monitoring mild traumatic brain injuries in football players
NASA Astrophysics Data System (ADS)
Ramasamy, Mouli; Varadan, Vijay K.
2016-04-01
Football players are more to violent impacts and injuries more than any athlete in any other sport. Concussion or mild traumatic brain injuries were one of the lesser known sports injuries until the last decade. With the advent of modern technologies in medical and engineering disciplines, people are now more aware of concussion detection and prevention. These concussions are often overlooked by football players themselves. The cumulative effect of these mild traumatic brain injuries can cause long-term residual brain dysfunctions. The principle of concussion is based the movement of the brain in the neurocranium and viscerocranium. The brain is encapsulated by the cerebrospinal fluid which acts as a protective layer for the brain. This fluid can protect the brain against minor movements, however, any rapid movements of the brain may mitigate the protective capability of the cerebrospinal fluid. In this paper, we propose a wireless health monitoring helmet that addresses the concerns of the current monitoring methods - it is non-invasive for a football player as helmet is not an additional gear, it is efficient in performance as it is equipped with EEG nanosensors and 3D accelerometer, it does not restrict the movement of the user as it wirelessly communicates to the remote monitoring station, requirement of individual monitoring stations are not required for each player as the ZigBee protocol can couple multiple transmitters with one receiver. A helmet was developed and validated according to the above mentioned parameters.
Wireless nanosensors for monitoring concussion of football players
NASA Astrophysics Data System (ADS)
Ramasamy, Mouli; Harbaugh, Robert E.; Varadan, Vijay K.
2015-04-01
Football players are more to violent impacts and injuries more than any athlete in any other sport. Concussion or mild traumatic brain injuries were one of the lesser known sports injuries until the last decade. With the advent of modern technologies in medical and engineering disciplines, people are now more aware of concussion detection and prevention. These concussions are often overlooked by football players themselves. The cumulative effect of these mild traumatic brain injuries can cause long-term residual brain dysfunctions. The principle of concussion is based the movement of the brain in the neurocranium and viscerocranium. The brain is encapsulated by the cerebrospinal fluid which acts as a protective layer for the brain. This fluid can protect the brain against minor movements, however, any rapid movements of the brain may mitigate the protective capability of the cerebrospinal fluid. In this paper, we propose a wireless health monitoring helmet that addresses the concerns of the current monitoring methods - it is non-invasive for a football player as helmet is not an additional gear, it is efficient in performance as it is equipped with EEG nanosensors and 3D accelerometer, it does not restrict the movement of the user as it wirelessly communicates to the remote monitoring station, requirement of individual monitoring stations are not required for each player as the ZigBee protocol can couple multiple transmitters with one receiver. A helmet was developed and validated according to the above mentioned parameters.
Fluid Therapy: Double-Edged Sword during Critical Care?
Benes, Jan; Kirov, Mikhail; Kuzkov, Vsevolod; Lainscak, Mitja; Molnar, Zsolt; Voga, Gorazd; Monnet, Xavier
2015-01-01
Fluid therapy is still the mainstay of acute care in patients with shock or cardiovascular compromise. However, our understanding of the critically ill pathophysiology has evolved significantly in recent years. The revelation of the glycocalyx layer and subsequent research has redefined the basics of fluids behavior in the circulation. Using less invasive hemodynamic monitoring tools enables us to assess the cardiovascular function in a dynamic perspective. This allows pinpointing even distinct changes induced by treatment, by postural changes, or by interorgan interactions in real time and enables individualized patient management. Regarding fluids as drugs of any other kind led to the need for precise indication, way of administration, and also assessment of side effects. We possess now the evidence that patient centered outcomes may be altered when incorrect time, dose, or type of fluids are administered. In this review, three major features of fluid therapy are discussed: the prediction of fluid responsiveness, potential harms induced by overzealous fluid administration, and finally the problem of protocol-led treatments and their timing. PMID:26798642
Fluid Therapy: Double-Edged Sword during Critical Care?
Benes, Jan; Kirov, Mikhail; Kuzkov, Vsevolod; Lainscak, Mitja; Molnar, Zsolt; Voga, Gorazd; Monnet, Xavier
2015-01-01
Fluid therapy is still the mainstay of acute care in patients with shock or cardiovascular compromise. However, our understanding of the critically ill pathophysiology has evolved significantly in recent years. The revelation of the glycocalyx layer and subsequent research has redefined the basics of fluids behavior in the circulation. Using less invasive hemodynamic monitoring tools enables us to assess the cardiovascular function in a dynamic perspective. This allows pinpointing even distinct changes induced by treatment, by postural changes, or by interorgan interactions in real time and enables individualized patient management. Regarding fluids as drugs of any other kind led to the need for precise indication, way of administration, and also assessment of side effects. We possess now the evidence that patient centered outcomes may be altered when incorrect time, dose, or type of fluids are administered. In this review, three major features of fluid therapy are discussed: the prediction of fluid responsiveness, potential harms induced by overzealous fluid administration, and finally the problem of protocol-led treatments and their timing.
Shaparin, Naum; Mehta, Neel; Kunkel, Frank; Stripp, Richard; Borg, Damon; Kolb, Elizabeth
2017-11-01
Interpretation limitations of urine drug testing and the invasiveness of blood toxicology have motivated the desire for the development of simpler methods to assess biologically active drug levels on an individualized patient basis. Oral fluid is a matrix well-suited for the challenge because collections are based on simple noninvasive procedures and drug concentrations better correlate to blood drug levels as oral fluid is a filtrate of the blood. Well-established pharmacokinetic models were utilized to generate oral fluid steady state concentration ranges to assess the interpretive value of the alternative matrix to monitor steady state plasma oxycodone levels. Paired oral fluid and plasma samples were collected from patients chronically prescribed oxycodone and quantitatively analyzed by liquid chromatography tandem mass spectrometry. Steady state plasma concentration ranges were calculated for each donor and converted to an equivalent range in oral fluid. Measured plasma and oral fluid oxycodone concentrations were compared with respective matrix-matched steady state ranges, using each plasma steady state classification as the control. A high degree of correlation was observed between matrices when classifying donors according to expected steady state oxycodone concentration. Agreement between plasma and oral fluid steady state classifications was observed in 75.6% of paired samples. This study supports novel application of basic pharmacokinetic knowledge to the pain management industry, simplifying and improving individualized drug monitoring and risk assessment through the use of oral fluid drug testing. Many benefits of established therapeutic drug monitoring in plasma can be realized in oral fluid for patients chronically prescribed oxycodone at steady state. © 2017 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
Lahner, D; Kabon, B; Marschalek, C; Chiari, A; Pestel, G; Kaider, A; Fleischmann, E; Hetz, H
2009-09-01
Fluid management guided by oesophageal Doppler monitor has been reported to improve perioperative outcome. Stroke volume variation (SVV) is considered a reliable clinical predictor of fluid responsiveness. Consequently, the aim of the present trial was to evaluate the accuracy of SVV determined by arterial pulse contour (APCO) analysis, using the FloTrac/Vigileo system, to predict fluid responsiveness as measured by the oesophageal Doppler. Patients undergoing major abdominal surgery received intraoperative fluid management guided by oesophageal Doppler monitoring. Fluid boluses of 250 ml each were administered in case of a decrease in corrected flow time (FTc) to <350 ms. Patients were connected to a monitoring device, obtaining SVV by APCO. Haemodynamic variables were recorded before and after fluid bolus application. Fluid responsiveness was defined as an increase in stroke volume index >10%. The ability of SVV to predict fluid responsiveness was assessed by calculation of the area under the receiver operating characteristic (ROC) curve. Twenty patients received 67 fluid boluses. Fifty-two of the 67 fluid boluses administered resulted in fluid responsiveness. SVV achieved an area under the ROC curve of 0.512 [confidence interval (CI) 0.32-0.70]. A cut-off point for fluid responsiveness was found for SVV > or =8.5% (sensitivity: 77%; specificity: 43%; positive predictive value: 84%; and negative predictive value: 33%). This prospective, interventional observer-blinded study demonstrates that SVV obtained by APCO, using the FloTrac/Vigileo system, is not a reliable predictor of fluid responsiveness in the setting of major abdominal surgery.
Reservoir Stimulation Optimization with Operational Monitoring for Creation of EGS
Fernandez, Carlos A.
2013-09-25
EGS field projects have not sustained production at rates greater than ½ of what is needed for economic viability. The primary limitation that makes commercial EGS infeasible is our current inability to cost-effectively create high-permeability reservoirs from impermeable, igneous rock within the 3,000-10,000 ft depth range. Our goal is to develop a novel fracturing fluid technology that maximizes reservoir permeability while reducing stimulation cost and environmental impact. Laboratory equipment development to advance laboratory characterization/monitoring is also a priority of this project to study and optimize the physicochemical properties of these fracturing fluids in a range of reservoir conditions. Barrier G is the primarily intended GTO barrier to be addressed as well as support addressing barriers D, E and I.
Reservoir Stimulation Optimization with Operational Monitoring for Creation of EGS
Carlos A. Fernandez
2014-09-15
EGS field projects have not sustained production at rates greater than ½ of what is needed for economic viability. The primary limitation that makes commercial EGS infeasible is our current inability to cost-effectively create high-permeability reservoirs from impermeable, igneous rock within the 3,000-10,000 ft depth range. Our goal is to develop a novel fracturing fluid technology that maximizes reservoir permeability while reducing stimulation cost and environmental impact. Laboratory equipment development to advance laboratory characterization/monitoring is also a priority of this project to study and optimize the physicochemical properties of these fracturing fluids in a range of reservoir conditions. Barrier G is the primarily intended GTO barrier to be addressed as well as support addressing barriers D, E and I.
Gas House Autonomous System Monitoring
NASA Technical Reports Server (NTRS)
Miller, Luke; Edsall, Ashley
2015-01-01
Gas House Autonomous System Monitoring (GHASM) will employ Integrated System Health Monitoring (ISHM) of cryogenic fluids in the High Pressure Gas Facility at Stennis Space Center. The preliminary focus of development incorporates the passive monitoring and eventual commanding of the Nitrogen System. ISHM offers generic system awareness, adept at using concepts rather than specific error cases. As an enabler for autonomy, ISHM provides capabilities inclusive of anomaly detection, diagnosis, and abnormality prediction. Advancing ISHM and Autonomous Operation functional capabilities enhances quality of data, optimizes safety, improves cost effectiveness, and has direct benefits to a wide spectrum of aerospace applications.
Wilms, Heath; Mittal, Anubhav; Haydock, Matthew D; van den Heever, Marc; Devaud, Marcello; Windsor, John A
2014-04-01
To review the literature on goal directed fluid therapy and evaluate the quality of evidence for each combination of goal and monitoring method. A search of major digital databases and hand search of references was conducted. All studies assessing the clinical utility of a specific fluid therapy goal or set of goals using any monitoring method were included. Data was extracted using a pre-determined pro forma and papers were evaluated using GRADE principles to assess evidence quality. Eighty-one papers met the inclusion criteria, investigating 31 goals and 22 methods for monitoring fluid therapy in 13052 patients. In total there were 118 different goal/method combinations. Goals with high evidence quality were central venous lactate and stroke volume index. Goals with moderate quality evidence were sublingual microcirculation flow, the oxygen extraction ratio, cardiac index, cardiac output, and SVC collapsibility index. This review has highlighted the plethora of goals and methods for monitoring fluid therapy. Strikingly, there is scant high quality evidence, in particular for non-invasive G/M combinations in non-operative and non-intensive care settings. There is an urgent need to address this research gap, which will be helped by methodologies to compare utility of G/M combinations. Copyright © 2014 Elsevier Inc. All rights reserved.
Dams, Riet; Choo, Robin E.; Lambert, Willy E.; Jones, Hendree; Huestis, Marilyn A.
2007-01-01
Interest in oral fluid as an alternative matrix for monitoring drug use is due to its ease-of-collection and non-invasiveness; however, limited data are available on the disposition of drugs into oral fluid. The objective of this research was to provide data on the presence and concentrations of heroin, cocaine and multiple metabolites in oral fluid after illicit opioid and cocaine use. Thrice weekly oral fluid specimens (N=403) from 16 pregnant opiate-dependent women were obtained with the Salivette® oral fluid collection device. Evidence of heroin (N=62) and cocaine (N=130) use was detected in oral fluid by LC-APCI-MS/MS. 6-Acetylmorphine (6-AM), heroin and morphine were the major opiates detected, with median concentrations of 5.2, 2.3, and 7.5 μg/L, respectively. Cocaine and benzoylecgonine (BE) had median concentrations of 6.4 and 3.4 μg/L. Application of the Substance Abuse Mental Health Services Administration (SAMHSA) recommended cutoffs for morphine and codeine (40 μg/L), 6-AM (4 μg/L) and cocaine and BE (8 μg/L), yielded 28 opiate- and 50 cocaine-positive specimens. Oral fluid is a promising alternative matrix to monitor opiate and cocaine use in drug testing programs. These data guide interpretation of oral fluid test results and evaluate currently proposed SAMHSA oral fluid testing cutoffs. PMID:17008030
[Intrapartum amnioinfusion in patients with meconium-stained amniotic fluid].
Engel, Karina; Samborska, Monika; Bilar, Marek; Sipak-Szmigiel, Olimpia; Ronin-Walknowska, Elzbieta
2008-09-01
The aim of the study was to evaluate the effect of intrapartum amnioinfusion in the presence of meconium stained amniotic fluid. 93 women with meconium-stained amniotic fluid were assigned to receive amnioinfusion or no amnioinfusion (128 women). The trials were evaluated for fetal distress syndrome, route of delivery, fetal acidemia, Apgar score at 1 and 5 min., meconium aspiration syndrome, postpartum endometritis and maternal hospital stays. Amnioinfusion in cases of meconium-stained fluid did not improve the number of fetal distress symptoms during fetal heart rate monitoring. Amnioinfusion was associated with a significant decrease of neonatal acidemia although it did not improve Apgar score. In our study amnioinfusion was not associated with reduction in the incidence of neonatal outcome and puerperial complications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taleyarkhan, R.P.; Kim, S.H.; Haines, J.
The authors provide a perspective overview of pretest modeling and analysis work related to thermal shock effects in spallation neutron source targets that were designed for conducting thermal shock experiments at the Los Alamos Neutron Science Center (LANSCE). Data to be derived are to be used for benchmarking computational tools as well as to assess the efficacy of optical gauges for monitoring dynamic fluid pressures and phenomena such as the onset of cavitation.
Pestel, G; Fukui, K; Higashi, M; Schmidtmann, I; Werner, C
2018-06-01
An ideal non-invasive monitoring system should provide accurate and reproducible measurements of clinically relevant variables that enables clinicians to guide therapy accordingly. The monitor should be rapid, easy to use, readily available at the bedside, operator-independent, cost-effective and should have a minimal risk and side effect profile for patients. An example is the introduction of pulse oximetry, which has become established for non-invasive monitoring of oxygenation worldwide. A corresponding non-invasive monitoring of hemodynamics and perfusion could optimize the anesthesiological treatment to the needs in individual cases. In recent years several non-invasive technologies to monitor hemodynamics in the perioperative setting have been introduced: suprasternal Doppler ultrasound, modified windkessel function, pulse wave transit time, radial artery tonometry, thoracic bioimpedance, endotracheal bioimpedance, bioreactance, and partial CO 2 rebreathing have been tested for monitoring cardiac output or stroke volume. The photoelectric finger blood volume clamp technique and respiratory variation of the plethysmography curve have been assessed for monitoring fluid responsiveness. In this manuscript meta-analyses of non-invasive monitoring technologies were performed when non-invasive monitoring technology and reference technology were comparable. The primary evaluation criterion for all studies screened was a Bland-Altman analysis. Experimental and pediatric studies were excluded, as were all studies without a non-invasive monitoring technique or studies without evaluation of cardiac output/stroke volume or fluid responsiveness. Most studies found an acceptable bias with wide limits of agreement. Thus, most non-invasive hemodynamic monitoring technologies cannot be considered to be equivalent to the respective reference method. Studies testing the impact of non-invasive hemodynamic monitoring technologies as a trend evaluation on outcome, as well as studies evaluating alternatives to the finger for capturing the raw signals for hemodynamic assessment, and, finally, studies evaluating technologies based on a flow time measurement are current topics of clinical research.
Using functional hemodynamic indicators to guide fluid therapy.
Bridges, Elizabeth
2013-05-01
Hemodynamic monitoring has traditionally relied on such static pressure measurements as pulmonary artery occlusion pressure and central venous pressure to guide fluid therapy. Over the past 15 years, however, there's been a shift toward less invasive or noninvasive monitoring methods, which use "functional" hemodynamic indicators that reflect ventilator-induced changes in preload and thereby more accurately predict fluid responsiveness. The author reviews the physiologic principles underlying functional hemodynamic indicators, describes how the indicators are calculated, and discusses when and how to use them to guide fluid resuscitation in critically ill patients.
The inhibitory effect of bovine rumen fluid on Salmonella typhimurium.
Chambers, P G; Lysons, R J
1979-05-01
The possible fate of Salmonella typhimurium in the rumen was investigated by monitoring rumen volatile fatty acids (VFA), lactate concentrations and pH over periods which included regular feeding and 48 h starvation. Preparations were made containing 50 per cent rumen fluid from the cow or VFA solutions, and then inoculated with S typhimurium. Viable counts before and after incubation for 24 h at 37 degrees C were compared. Incubation in broths with high concentrations of VFA and low pH resulted in a marked decrease in salmonella numbers, while lower VFA concentrations had little or no inhibitory effect on growth.
Hubbell, J.M.; Sisson, J.B.
1999-06-29
A monitoring well is described which includes: a conduit defining a passageway, the conduit having a proximal and opposite, distal end; a coupler connected in fluid flowing relationship with the passageway; and a porous housing borne by the coupler and connected in fluid flowing relation thereto. 8 figs.
Brom, Sarah Susanne; Schnitzspahn, Katharina Marlene; Melzer, Marlen; Hagner, Franziska; Bernhard, Anka; Kliegel, Matthias
2014-03-01
The aim of the present study was to test if a cognitive strategy improves older adults' prospective memory performance in a naturalistic health task. Moreover, it was tested if a possible strategy effect is moderated by individual differences. Therefore, a group of older adults was asked to perform a task taken from the medication adherence literature (i.e., blood pressure monitoring). Half of them were asked to form implementation intentions. Additionally, crystallized pragmatics and fluid mechanics, conscientiousness, self-efficacy, and lifestyle factors were assessed as possible moderators. Results showed a strong positive strategy effect on prospective memory. Moreover, the effect was qualified by a significant interaction and only emerged for participants with low levels in fluid mechanics. No other moderator showed an effect. In conclusion, an enhancing effect of implementation intentions on prospective memory seems to be dependent on individual differences in cognitive capacity and less related to key motivational or personality variables.
Pediatric Fluid and Electrolyte Therapy
Meyers, Rachel S.
2009-01-01
Managing fluids and electrolytes in children is an important skill for pharmacists, who can play an important role in monitoring therapy. Fluid therapy is divided into maintenance, deficit, and replacement requirements. The Holliday-Segar equation remains the standard method for calculating maintenance fluid requirements. Accounting for deficits when determining the fluid infusion rate is an important factor in treating dehydrated patients; deficit fluid is generally administered over the first 24 hours of hospitalization. Maintenance electrolyte requirements must be taken into account, with particular attention paid to sodium requirements, as recent evidence suggests that sodium needs in hospitalized children are higher than originally thought. Fluid therapy can also have an impact on drug therapy. Hydration status can affect the dose needed to achieve therapeutic concentrations, and dehydrated patients may be at risk for toxicity if standard doses of drugs with high volumes of distribution are used. Monitoring fluid and electrolyte therapy is an important role of the pediatric pharmacist. PMID:23055905
Decorte, Inge; Van Breedam, Wander; Van der Stede, Yves; Nauwynck, Hans J; De Regge, Nick; Cay, Ann Brigitte
2014-06-17
Oral fluid collected by means of ropes has the potential to replace serum for monitoring and surveillance of important swine pathogens. Until now, the most commonly used method to collect oral fluid is by hanging a cotton rope in a pen. However, concerns about the influence of rope material on subsequent immunological assays have been raised. In this study, we evaluated six different rope materials for the collection of oral fluid and the subsequent detection of total and PRRSV-specific antibodies of different isotypes in oral fluid collected from PRRSV-vaccinated and infected pigs. An initial experiment showed that IgA is the predominant antibody isotype in porcine saliva. Moreover, it was found that synthetic ropes may yield higher amounts of IgA, whereas all rope types seemed to be equally suitable for IgG collection. Although IgA is the predominant antibody isotype in porcine oral fluid, the PRRSV-specific IgA-based IPMA and ELISA tests were clearly not ideal for sensitive detection of PRRSV-specific IgA antibodies. In contrast, PRRSV-specific IgG in oral fluids was readily detected in PRRSV-specific IgG-based IPMA and ELISA tests, indicating that IgG is a more reliable isotype for monitoring PRRSV-specific antibody immunity in vaccinated/infected animals via oral fluids with the currently available tests. Since PRRSV-specific IgG detection seems more reliable than PRRSV-specific IgA detection for monitoring PRRSV-specific antibody immunity via oral fluids, and since all rope types yield equal amounts of IgG, it seems that the currently used cotton ropes are an appropriate choice for sample collection in PRRSV monitoring.
Tokarik, Monika; Sjöberg, Folke; Balik, Martin; Pafcuga, Igor; Broz, Ludomir
2013-01-01
This pilot trial aims at gaining support for the optimization of acute burn resuscitation through noninvasive continuous real-time hemodynamic monitoring using arterial pulse contour analysis. A group of 21 burned patients meeting preliminary criteria (age range 18-75 years with second- third- degree burns and TBSA ≥10-75%) was randomized during 2010. A hemodynamic monitoring through lithium dilution cardiac output was used in 10 randomized patients (LiDCO group), whereas those without LiDCO monitoring were defined as the control group. The modified Brooke/Parkland formula as a starting resuscitative formula, balanced crystalloids as the initial solutions, urine output of 0.5 ml/kg/hr as a crucial value of adequate intravascular filling were used in both groups. Additionally, the volume and vasopressor/inotropic support were based on dynamic preload parameters in the LiDCO group in the case of circulatory instability and oligouria. Statistical analysis was done using t-tests. Within the first 24 hours postburn, a significantly lower consumption of crystalloids was registered in LiDCO group (P = .04). The fluid balance under LiDCO control in combination with hourly diuresis contributed to reducing the cumulative fluid balance approximately by 10% compared with fluid management based on standard monitoring parameters. The amount of applied solutions in the LiDCO group got closer to Brooke formula whereas the urine output was at the same level in both groups (0.8 ml/kg/hr). The new finding in this study is that when a fluid resuscitation is based on the arterial waveform analysis, the initial fluid volume provided was significantly lower than that delivered on the basis of physician-directed fluid resuscitation (by urine output and mean arterial pressure).
Sakaguchi, Kazuhiko; Hirota, Yushi; Hashimoto, Naoko; Ogawa, Wataru; Hamaguchi, Tomoya; Matsuo, Toshihiro; Miyagawa, Jun-ichiro; Namba, Mitsuyoshi; Sato, Toshiyuki; Okada, Seiki; Tomita, Koji; Matsuhisa, Munehide; Kaneto, Hideaki; Kosugi, Keisuke; Maegawa, Hiroshi; Nakajima, Hiromu; Kashiwagi, Atsunori
2013-05-01
We developed a system for measuring glucose area under the curve (AUC) using minimally invasive interstitial fluid extraction technology (MIET). Sweat contamination during interstitial fluid glucose (IG) extraction affects the accuracy of glucose AUC measurement, because this technology uses extracted sodium ion levels as an internal standard. Therefore, we developed a sweat monitoring patch to reduce this effect and investigated its efficacy in volunteers undergoing oral glucose tolerance tests (OGTTs). Fifty diabetes mellitus inpatients and 10 healthy subjects undergoing the 75 g OGTT were included. Two sites on the forearm were pretreated with microneedle arrays, then hydrogels for interstitial fluid extraction were placed on the treated sites. Simultaneously, hydrogels for sweat monitoring were placed on untreated sites near the treated sites. Plasma glucose (PG) levels were measured every 30 min for 2 h to calculate reference AUC values. Using MIET, IG AUC was calculated from extracted glucose and sodium ion levels after attachment of the hydrogel for 2 h. Good correlation between IG AUC measurements using MIET and reference AUCs measured using PG levels was confirmed over a wide AUC range (202-610 mg/h/dl) after correction for the sweat-induced error detected by the hydrogel patches on the nonpretreated skin. Strong correlation between IG AUC and peak glucose levels indicates that glucose spikes can be easily detected by this system. We confirmed the effectiveness of a sweat monitoring patch for precise AUC measurement using MIET. This novel, easy-to-use system has potential for glucose excursion evaluation in daily clinical practice. © 2013 Diabetes Technology Society.
Sakaguchi, Kazuhiko; Hirota, Yushi; Hashimoto, Naoko; Ogawa, Wataru; Hamaguchi, Tomoya; Toshihiro, Matsuo; Miyagawa, Jun-ichiro; Namba, Mitsuyoshi; Sato, Toshiyuki; Okada, Seiki; Tomita, Koji; Matsuhisa, Munehide; Kaneto, Hideaki; Kosugi, Keisuke; Maegawa, Hiroshi; Nakajima, Hiromu; Kashiwagi, Atsunori
2013-01-01
Aims: We developed a system for measuring glucose area under the curve (AUC) using minimally invasive interstitial fluid extraction technology (MIET). Sweat contamination during interstitial fluid glucose (IG) extraction affects the accuracy of glucose AUC measurement, because this technology uses extracted sodium ion levels as an internal standard. Therefore, we developed a sweat monitoring patch to reduce this effect and investigated its efficacy in volunteers undergoing oral glucose tolerance tests (OGTTs). Materials and Methods: Fifty diabetes mellitus inpatients and 10 healthy subjects undergoing the 75 g OGTT were included. Two sites on the forearm were pretreated with microneedle arrays, then hydrogels for interstitial fluid extraction were placed on the treated sites. Simultaneously, hydrogels for sweat monitoring were placed on untreated sites near the treated sites. Plasma glucose (PG) levels were measured every 30 min for 2 h to calculate reference AUC values. Using MIET, IG AUC was calculated from extracted glucose and sodium ion levels after attachment of the hydrogel for 2 h. Results: Good correlation between IG AUC measurements using MIET and reference AUCs measured using PG levels was confirmed over a wide AUC range (202–610 mg/h/dl) after correction for the sweat-induced error detected by the hydrogel patches on the nonpretreated skin. Strong correlation between IG AUC and peak glucose levels indicates that glucose spikes can be easily detected by this system. Conclusion: We confirmed the effectiveness of a sweat monitoring patch for precise AUC measurement using MIET. This novel, easy-to-use system has potential for glucose excursion evaluation in daily clinical practice. PMID:23759401
Causes of death after fluid bolus resuscitation: new insights from FEAST
2013-01-01
The Fluid Expansion as Supportive Therapy (FEAST study) was an extremely well conducted study that gave unexpected results. The investigators had reported that febrile children with impaired perfusion treated in low-income countries without access to intensive care are more likely to die if they receive bolus resuscitation with albumin or saline compared with no bolus resuscitation at all. In a secondary analysis of the trial, published in BMC Medicine, the authors found that increased mortality was evident in patients who presented with clinical features of severe shock in isolation or in conjunction with features of respiratory or neurological failure. The cause of excess deaths was primarily refractory shock and not fluid overload. These features are consistent with a potential cardiotoxic or ischemia-reperfusion injury following resuscitation with boluses of intravenous fluid. Although these effects may have been amplified by the absence of invasive monitoring, mechanical ventilation or vasopressors, the results provide compelling insights into the effects of intravenous fluid resuscitation and potential adverse effects that extend beyond the initial resuscitation period. These data add to the increasing body of literature about the safety and efficacy of intravenous resuscitation fluids, which may be applicable to management of other populations of critically ill patients. PMID:23497460
Zhao, S; Ai, L; Zhang, H
2000-01-01
To discuss the significance of amnioinfusion and amniotic fluid exchange under continuous internal fetal heart rate (FHR) monitoring for management of fetal distress during labor. 136 cases with frequent variable deceleration (VD) and meconium stained amniotic fluid during labor were divided into two groups: the study group (68 cases) and the control group (68 cases). The former were treated by amnioinfusion and amniotic fluid exchange, while oxygen inhalation, change of body position, and intravenous infusion for the control group. In the study group, VD disappeared or relieved in 62 cases obviously, and the efficacy rate reached 91.2% (62/68). 48 cases with II degree meconium stained amniotic fluid were treated by amniotic fluid exchange, amniotic fluid became clear or turned to I degree stained in 39 cases. In the control group, VD relieved in 20 cases, the efficacy rate was 19.4%, significantly lower than that of the study group (P < 0.01). In the study group, cesarean section rate was 14.7% neonatal asphyxia 7.4% while they were 47.1% and 48.5% in the control group respectively (P < 0.01; P < 0.01). Neonatal pneumonia caused by meconium aspiration occurred in 13 cases, meconium aspiration syndrome (MAS) 8 cases, with 5 newborns died in the control group, while there was no neonatal death in the study group. There was no significant difference on puerperal morbidity between the 2 groups (P > 0.05). Amnioinfusion and AF exchange during labor are one of the effective treatment methods for fetal distress and prevention for MAS.
Time-Lapse Electrical Geophysical Monitoring of Amendment-Based Biostimulation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, Timothy C.; Versteeg, Roelof; Day-Lewis, Frederick D.
Biostimulation is increasingly used to accelerate microbial remediation of recalcitrant groundwater contaminants. Effective application of biostimulation requires successful emplacement of amendment in the contaminant target zone. Verification of remediation performance requires postemplacement assessment and contaminant monitoring. Sampling based approaches are expensive and provide low-density spatial and temporal information. Time-lapse electrical resistivity tomography (ERT) is an effective geophysical method for determining temporal changes in subsurface electrical conductivity. Because remedial amendments and biostimulation-related biogeochemical processes often change subsurface electrical conductivity, ERT can complement and enhance sampling-based approaches for assessing emplacement and monitoring biostimulation-based remediation. Field studies demonstrating the ability of time-lapse ERTmore » to monitor amendment emplacement and behavior were performed during a biostimulation remediation effort conducted at the Department of Defense Reutilization and Marketing Office (DRMO) Yard, in Brandywine, Maryland, United States. Geochemical fluid sampling was used to calibrate a petrophysical relation in order to predict groundwater indicators of amendment distribution. The petrophysical relations were field validated by comparing predictions to sequestered fluid sample results, thus demonstrating the potential of electrical geophysics for quantitative assessment of amendment-related geochemical properties. Crosshole radar zero-offset profile and borehole geophysical logging were also performed to augment the data set and validate interpretation. In addition to delineating amendment transport in the first 10 months after emplacement, the time-lapse ERT results show later changes in bulk electrical properties interpreted as mineral precipitation. Results support the use of more cost-effective surfacebased ERT in conjunction with limited field sampling to improve spatial and temporal monitoring of amendment emplacement and remediation performance.« less
Time-lapse electrical geophysical monitoring of amendment-based biostimulation
Johnson, Timothy C.; Versteeg, Roelof J.; Day-Lewis, Frederick D.; Major, William; Lane, John W.
2015-01-01
Biostimulation is increasingly used to accelerate microbial remediation of recalcitrant groundwater contaminants. Effective application of biostimulation requires successful emplacement of amendment in the contaminant target zone. Verification of remediation performance requires postemplacement assessment and contaminant monitoring. Sampling-based approaches are expensive and provide low-density spatial and temporal information. Time-lapse electrical resistivity tomography (ERT) is an effective geophysical method for determining temporal changes in subsurface electrical conductivity. Because remedial amendments and biostimulation-related biogeochemical processes often change subsurface electrical conductivity, ERT can complement and enhance sampling-based approaches for assessing emplacement and monitoring biostimulation-based remediation.Field studies demonstrating the ability of time-lapse ERT to monitor amendment emplacement and behavior were performed during a biostimulation remediation effort conducted at the Department of Defense Reutilization and Marketing Office (DRMO) Yard, in Brandywine, Maryland, United States. Geochemical fluid sampling was used to calibrate a petrophysical relation in order to predict groundwater indicators of amendment distribution. The petrophysical relations were field validated by comparing predictions to sequestered fluid sample results, thus demonstrating the potential of electrical geophysics for quantitative assessment of amendment-related geochemical properties. Crosshole radar zero-offset profile and borehole geophysical logging were also performed to augment the data set and validate interpretation.In addition to delineating amendment transport in the first 10 months after emplacement, the time-lapse ERT results show later changes in bulk electrical properties interpreted as mineral precipitation. Results support the use of more cost-effective surface-based ERT in conjunction with limited field sampling to improve spatial and temporal monitoring of amendment emplacement and remediation performance.
DSS 13 antenna monitor system. [Deep Space Network
NASA Technical Reports Server (NTRS)
Siev, B.; Bayergo, D.
1979-01-01
The development of a monitor system for the DSS 13 antenna is presented. The system checks for accumulator pressures, differential pressures, wind velocity, power supplies, fluid temperatures, and fluid levels. It was concluded that the system performed properly in high winds and correctly reported all malfunctions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... for fluid catalytic cracking units (FCCU) and fluid coking units (FCU). 60.105a Section 60.105a... and operations for fluid catalytic cracking units (FCCU) and fluid coking units (FCU). (a) FCCU and... Emission Standards for Hazardous Air Pollutants for Petroleum Refineries: Catalytic Cracking Units...
Code of Federal Regulations, 2010 CFR
2010-07-01
... for fluid catalytic cracking units (FCCU) and fluid coking units (FCU). 60.105a Section 60.105a... and operations for fluid catalytic cracking units (FCCU) and fluid coking units (FCU). (a) FCCU and... Emission Standards for Hazardous Air Pollutants for Petroleum Refineries: Catalytic Cracking Units...
Quantification of CO2-FLUID-ROCK Reactions Using Reactive and Non-Reactive Tracers
NASA Astrophysics Data System (ADS)
Matter, J.; Stute, M.; Hall, J. L.; Mesfin, K. G.; Gislason, S. R.; Oelkers, E. H.; Sigfússon, B.; Gunnarsson, I.; Aradottir, E. S.; Alfredsson, H. A.; Gunnlaugsson, E.; Broecker, W. S.
2013-12-01
Carbon dioxide mineralization via fluid-rock reactions provides the most effective and long-term storage option for geologic carbon storage. Injection of CO2 in geologic formations induces CO2 -fluid-rock reactions that may enhance or decrease the storage permanence and thus the long-term safety of geologic carbon storage. Hence, quantitative characterization of critical CO2 -fluid-rock interactions is essential to assess the storage efficiency and safety of geologic carbon storage. In an attempt to quantify in-situ fluid-rock reactions and CO2 transport relevant for geologic carbon storage, we are testing reactive (14C, 13C) and non-reactive (sodium fluorescein, amidorhodamine G, SF5CF3, and SF6) tracers in an ongoing CO2 injection in a basaltic storage reservoir at the CARBFIX pilot injection site in Iceland. At the injection site, CO2 is dissolved in groundwater and injected into a permeable basalt formation located 500-800 m below the surface [1]. The injected CO2 is labeled with 14C by dynamically adding calibrated amounts of H14CO3-solution into the injection stream in addition to the non-reactive tracers. Chemical and isotopic analyses of fluid samples collected in a monitoring well, reveal fast fluid-rock reactions. Maximum SF6 concentration in the monitoring well indicates the bulk arrival of the injected CO2 solution but dissolved inorganic carbon (DIC) concentration and pH values close to background, and a potentially lower 14C to SF6 ratio than the injection ratio suggest that most of the injected CO2 has reacted with the basaltic rocks. This is supported by δ13CDIC, which shows a drop from values close to the δ 13C of the injected CO2 gas (-3‰ VPDB) during breakthrough of the CO2 plume to subsequent more depleted values (-11.25‰ VPDB), indicating precipitation of carbonate minerals. Preliminary mass balance calculations using mixing relationships between the background water in the storage formation and the injected solution, suggest that approximately 85% of the injected CO2 must have reacted along the flow path from the injection well to the monitoring well within less than one year. Monitoring is still going on and we will extend the time series and the mass balance accordingly. Our study demonstrates that by combining reactive and non-reactive tracers, we are able to quantify CO2-fluid-rock interactions on a reservoir scale. [1] Gislason et al. (2010), Int. J. Greenh. Gas Con. 4, 537-545.
NASA Astrophysics Data System (ADS)
Zhong, X.; Galvez, M. E.
2017-12-01
Metamorphic fluids are a crucial ingredient of geodynamic evolution, i.e. heat transfer, rock mechanics and metamorphic/metasomatic reactions. During crustal evolution at elevated P and T, rock forming components can be effectively fractionated from the reactive rock system by at least two processes: 1. extraction from porous rocks by liquid phases such as solute-bearing (e.g. Na+, Mg2+) aqueous fluids or partial melts. 2. isolation from effective bulk rock composition due to slow intragranular diffusion in high-P refractory phases such as garnet. The effect of phase fractionation (garnet, partial melt and aqueous species) on fluid - rock composition and properties remain unclear, mainly due to a high demand in quantitative computations of the thermodynamic interactions between rocks and fluids over a wide P-T range. To investigate this problem, we build our work on an approach initially introduced by Galvez et al., (2015) with new functionalities added in a MATLAB code (Rubisco). The fluxes of fractionated components in fluid, melt and garnet are monitored along a typical prograde P-T path for a model crustal pelite. Some preliminary results suggest a marginal effect of fractionated aqueous species on fluid and rock properties (e.g. pH, composition), but the corresponding fluxes are significant in the context of mantle wedge metasomatism. Our work provides insight into the role of high-P phase fractionation on mass redistribution between the surface and deep Earth in subduction zones. Existing limitations relevant to our liquid/mineral speciation/fractionation model will be discussed as well. ReferencesGalvez, M.E., Manning, C.E., Connolly, J.A.D., Rumble, D., 2015. The solubility of rocks in metamorphic fluids: A model for rock-dominated conditions to upper mantle pressure and temperature. Earth Planet. Sci. Lett. 430, 486-498.
Brachmann, Johannes; Böhm, Michael; Rybak, Karin; Klein, Gunnar; Butter, Christian; Klemm, Hanno; Schomburg, Rolf; Siebermair, Johannes; Israel, Carsten; Sinha, Anil-Martin; Drexler, Helmut
2011-07-01
The Optimization of Heart Failure Management using OptiVol Fluid Status Monitoring and CareLink (OptiLink HF) study is designed to investigate whether OptiVol fluid status monitoring with an automatically generated wireless CareAlert notification via the CareLink Network can reduce all-cause death and cardiovascular hospitalizations in an HF population, compared with standard clinical assessment. Methods Patients with newly implanted or replacement cardioverter-defibrillator devices with or without cardiac resynchronization therapy, who have chronic HF in New York Heart Association class II or III and a left ventricular ejection fraction ≤35% will be eligible to participate. Following device implantation, patients are randomized to either OptiVol fluid status monitoring through CareAlert notification or regular care (OptiLink 'on' vs. 'off'). The primary endpoint is a composite of all-cause death or cardiovascular hospitalization. It is estimated that 1000 patients will be required to demonstrate superiority of the intervention group to reduce the primary outcome by 30% with 80% power. The OptiLink HF study is designed to investigate whether early detection of congestion reduces mortality and cardiovascular hospitalization in patients with chronic HF. The study is expected to close recruitment in September 2012 and to report first results in May 2014.
Fluid mechanics in fluids at rest.
Brenner, Howard
2012-07-01
Using readily available experimental thermophoretic particle-velocity data it is shown, contrary to current teachings, that for the case of compressible flows independent dye- and particle-tracer velocity measurements of the local fluid velocity at a point in a flowing fluid do not generally result in the same fluid velocity measure. Rather, tracer-velocity equality holds only for incompressible flows. For compressible fluids, each type of tracer is shown to monitor a fundamentally different fluid velocity, with (i) a dye (or any other such molecular-tagging scheme) measuring the fluid's mass velocity v appearing in the continuity equation and (ii) a small, physicochemically and thermally inert, macroscopic (i.e., non-Brownian), solid particle measuring the fluid's volume velocity v(v). The term "compressibility" as used here includes not only pressure effects on density, but also temperature effects thereon. (For example, owing to a liquid's generally nonzero isobaric coefficient of thermal expansion, nonisothermal liquid flows are to be regarded as compressible despite the general perception of liquids as being incompressible.) Recognition of the fact that two independent fluid velocities, mass- and volume-based, are formally required to model continuum fluid behavior impacts on the foundations of contemporary (monovelocity) fluid mechanics. Included therein are the Navier-Stokes-Fourier equations, which are now seen to apply only to incompressible fluids (a fact well-known, empirically, to experimental gas kineticists). The findings of a difference in tracer velocities heralds the introduction into fluid mechanics of a general bipartite theory of fluid mechanics, bivelocity hydrodynamics [Brenner, Int. J. Eng. Sci. 54, 67 (2012)], differing from conventional hydrodynamics in situations entailing compressible flows and reducing to conventional hydrodynamics when the flow is incompressible, while being applicable to both liquids and gases.
STS-57 MS3 Wisoff monitors FARE II activity on the middeck of OV-105
1993-07-01
STS057-39-021 (21 June-1 July 1993) --- Astronaut Peter J. K. (Jeff) Wisoff, mission specialist, monitors the Fluid Acquisition and Resupply Experiment (FARE II), housed in four middeck lockers onboard the Space Shuttle Endeavour. The successor to FARE I (STS 53, 1992), FARE II was designed to demonstrate the effectiveness of a device to alleviate the problems associated with vapor-free liquid transfer.
Fluid therapy in critically ill patients: perspectives from the right heart.
Elbers, Paul; Rodrigus, Tim; Nossent, Esther; Malbrain, Manu L N G; Vonk-Noordegraaf, Anton
2015-01-01
As right heart function can affect outcome in the critically ill patient, a thorough understanding of factors determining right heart performance in health and disease is pivotal for the critical care physician. This review focuses on fluid therapy, which remains controversial in the setting of impending or overt right heart failure. In this context, we will attempt to elucidate which patients are likely to benefit from fluid administration and for which patients fluid therapy would likely be harmful. Following a general discussion of right heart function and failure, we specifically focus on important causes of right heart failure in the critically ill, i.e. sepsis induced myocardial dysfunction, the acute respiratory distress syndrome, acute pulmonary embolism and the effects of positive pressure ventilation. It is argued that fluid therapy should always be cautiously administered with the right heart in mind, which calls for close multimodal monitoring.
Roßteuscher-Carl, Katrin; Fricke, Sabine; Hacker, Michael C; Schulz-Siegmund, Michaela
2015-12-30
Ethinylestradiol (EE) as a highly active and low dosed compound is prone to oxidative degradation. The stability of the drug substance is therefore a critical parameter that has to be considered during drug formulation. Beside the stability of the drug substance, granule particle size and moisture are critical quality attributes (CQA) of the fluid bed granulation process which influence the tableting ability of the resulting granules. Both CQA should therefore be monitored during the production process by process analytic technology (PAT) according to ICH Q8. This work focusses on the effects of drying conditions on the stability of EE in a fluid-bed granulation process. We quantified EE degradation products 6-alpha-hydroxy-EE, 6-beta-hydroxy-EE, 9(11)-dehydro-EE and 6-oxo-EE during long time storage and accelerated conditions. PAT-tools that monitor granule particle size (Spatial filtering technology) and granule moisture (Microwave resonance technology) were applied and compared with off-line methods. We found a relevant influence of residual granule moisture and thermic stress applied during granulation on the storage stability of EE, whereas no degradation was found immediately after processing. Hence we conclude that drying parameters have a relevant influence on long term EE stability. Copyright © 2015 Elsevier B.V. All rights reserved.
A nonintrusive nuclear monitor for measuring liquid contents in sealed vessels
NASA Technical Reports Server (NTRS)
Singh, J. J.; Mall, G. H.
1984-01-01
A nonintrusive nuclear technique for monitoring fluid contents in sealed vessels, regardless of the fluid distribution inside the vessels is described. The technique is applicable to all-g environments. It is based on the differences in Cesium-137 gamma ray attenuation coefficients in air and the test liquids.
NASA Astrophysics Data System (ADS)
Kinoshita, C.; Saffer, D.; Kopf, A.; Roesner, A.; Wallace, L. M.; Araki, E.; Kimura, T.; Machida, Y.; Kobayashi, R.; Davis, E.; Toczko, S.; Carr, S.
2018-02-01
One primary objective of Integrated Ocean Drilling Program Expedition 365, conducted as part of the Nankai Trough Seismogenic Zone Experiment, was to recover a temporary observatory emplaced to monitor formation pore fluid pressure and temperature within a splay fault in the Nankai subduction zone offshore SW Honshu, Japan. Here we use a 5.3 year time series of formation pore fluid pressure, and in particular the response to ocean tidal loading, to evaluate changes in pore pressure and formation and fluid elastic properties induced by earthquakes. Our analysis reveals 31 earthquake-induced perturbations. These are dominantly characterized by small transient increases in pressure (28 events) and decreases in ocean tidal loading efficiency (14 events) that reflect changes to formation or fluid compressibility. The observed perturbations follow a magnitude-distance threshold similar to that reported for earthquake-driven hydrological effects in other settings. To explore the mechanisms that cause these changes, we evaluate the expected static and dynamic strains from each earthquake. The expected static strains are too small to explain the observed pressure changes. In contrast, estimated dynamic strains correlate with the magnitude of changes in both pressure and loading efficiency. We propose potential mechanism for the changes and subsequent recovery, which is exsolution of dissolved gas in interstitial fluids in response to shaking.
Vein networks in hydrothermal systems provide constraints for the monitoring of active volcanoes.
Cucci, Luigi; Di Luccio, Francesca; Esposito, Alessandra; Ventura, Guido
2017-03-10
Vein networks affect the hydrothermal systems of many volcanoes, and variations in their arrangement may precede hydrothermal and volcanic eruptions. However, the long-term evolution of vein networks is often unknown because data are lacking. We analyze two gypsum-filled vein networks affecting the hydrothermal field of the active Lipari volcanic Island (Italy) to reconstruct the dynamics of the hydrothermal processes. The older network (E1) consists of sub-vertical, N-S striking veins; the younger network (E2) consists of veins without a preferred strike and dip. E2 veins have larger aperture/length, fracture density, dilatancy, and finite extension than E1. The fluid overpressure of E2 is larger than that of E1 veins, whereas the hydraulic conductance is lower. The larger number of fracture intersections in E2 slows down the fluid movement, and favors fluid interference effects and pressurization. Depths of the E1 and E2 hydrothermal sources are 0.8 km and 4.6 km, respectively. The decrease in the fluid flux, depth of the hydrothermal source, and the pressurization increase in E2 are likely associated to a magma reservoir. The decrease of fluid discharge in hydrothermal fields may reflect pressurization at depth potentially preceding hydrothermal explosions. This has significant implications for the long-term monitoring strategy of volcanoes.
Fluid therapy and the hypovolemic microcirculation.
Gruartmoner, G; Mesquida, J; Ince, Can
2015-08-01
In shock states, optimizing intravascular volume is crucial to promote an adequate oxygen delivery to the tissues. Our current practice in fluid management pivots on the Frank-Starling law of the heart, and the effects of fluids are measured according to the induced changes on stroke volume. The purpose of this review is to evaluate the boundaries of current macrohemodynamic approach to fluid administration, and to introduce the microcirculatory integration as a fundamental part of tissue perfusion monitoring. Macrocirculatory changes induced by volume expansion are not always coupled to proportional changes in microcirculatory perfusion. Loss of hemodynamic coherence limits the value of guiding fluid therapy according to macrohemodynamics, and highlights the importance of evaluating the ultimate target of volume administration, the microcirculation. Current approach to intravascular volume optimization is made from a macrohemodynamic perspective. However, several situations wherein macrocirculatory and microcirculatory coherence is lost have been described. Future clinical trials should explore the usefulness of integrating the microcirculatory evaluation in fluid optimization.
Monitoring of organic contaminants in sediments using low field proton nuclear magnetic resonance
NASA Astrophysics Data System (ADS)
Zhang, Chi; Rupert, Yuri
2016-04-01
The effective monitoring of soils and groundwater contaminated with organic compounds is an important goal of many environmental restoration efforts. Recent geophysical methods such as electrical resistivity, complex conductivity, and ground penetrating radar have been successfully applied to characterize organic contaminants in the subsurface and to monitor remediation process both in laboratory and in field. Low field proton nuclear magnetic resonance (NMR) is a geophysical tool sensitive to the molecular-scale physical and chemical environment of hydrogen-bearing fluids in geological materials and shows promise as a novel method for monitoring contaminant remediation. This laboratory research focuses on measurements on synthetic samples to determine the sensitivity of NMR to the presence of organic contaminants and improve understanding of relationships between NMR observables, hydrological properties of the sediments, and amount and state of contaminants in porous media. Toluene, a light non-aqueous phase liquid (LNAPL) has been selected as a representative organic contaminant. Three types of porous media (pure silica sands, montmorillonite clay, and various sand-clay mixtures with different sand/clay ratios) were prepared as synthetic sediments. NMR relaxation time (T2) and diffusion-relaxation (D - T2) correlation measurements were performed in each sediment saturated with water and toluene mixed fluid at assorted concentrations (0% toluene and 100% water, 1% toluene and 99% water, 5% toluene and 95% water, 25% toluene and 75% water, and 100% toluene and 0% water) to 1) understand the effect of different porous media on the NMR responses in each fluid mixture, 2) investigate the role of clay content on T2 relaxation of each fluid, 3) quantify the amount hydrocarbons in the presence of water in each sediment, and 4) resolve hydrocarbons from water in D - T2 map. Relationships between the compositions of porous media, hydrocarbon concentration, and hydraulic properties of sediments will be presented and discussed. A minimum toluene detection limit has been established, and influences on NMR signals from increasing contaminant concentration have been investigated as well. It is evident in our data that the dominant control of porous media on NMR responses relies on clay content in the sand-clay mixture.
Microseismic monitoring: a tool for reservoir characterization.
NASA Astrophysics Data System (ADS)
Shapiro, S. A.
2011-12-01
Characterization of fluid-transport properties of rocks is one of the most important, yet one of most challenging goals of reservoir geophysics. There are some fundamental difficulties related to using active seismic methods for estimating fluid mobility. However, it would be very attractive to have a possibility of exploring hydraulic properties of rocks using seismic methods because of their large penetration range and their high resolution. Microseismic monitoring of borehole fluid injections is exactly the tool to provide us with such a possibility. Stimulation of rocks by fluid injections belong to a standard development practice of hydrocarbon and geothermal reservoirs. Production of shale gas and of heavy oil, CO2 sequestrations, enhanced recovery of oil and of geothermal energy are branches that require broad applications of this technology. The fact that fluid injection causes seismicity has been well-established for several decades. Observations and data analyzes show that seismicity is triggered by different processes ranging from linear pore pressure diffusion to non-linear fluid impact onto rocks leading to their hydraulic fracturing and strong changes of their structure and permeability. Understanding and monitoring of fluid-induced seismicity is necessary for hydraulic characterization of reservoirs, for assessments of reservoir stimulation and for controlling related seismic hazard. This presentation provides an overview of several theoretical, numerical, laboratory and field studies of fluid-induced microseismicity, and it gives an introduction into the principles of seismicity-based reservoir characterization.
Haemodynamic coherence - The relevance of fluid therapy.
Arnemann, Philip; Seidel, Laura; Ertmer, Christian
2016-12-01
The ultimate goal of fluid therapy is to improve the oxygenation of cells by improving the cardiac output, thus improving microcirculation by optimizing macrocirculation. This haemodynamic coherence is often altered in patients with haemorrhagic shock and sepsis. The loss of haemodynamic coherence is associated with adverse outcomes. It may be influenced by the mechanisms of the underlying disease and properties of different fluids used for resuscitation in these critically ill patients. Monitoring microcirculation and haemodynamic coherence may be an additional tool to predict the response to fluid administration. In addition, microcirculatory analysis may support the clinician in his decision to not administer fluids when microcirculatory blood flow is preserved. In future, the indication, guidance and termination of fluid therapy may be assessed by bedside microvascular analysis in combination with standard haemodynamic monitoring. Copyright © 2016 Elsevier Ltd. All rights reserved.
Apparatus and method for quantitative determination of materials contained in fluids
Radziemski, Leon J.; Cremers, David A.
1985-01-01
Apparatus and method for near real-time in-situ monitoring of particulates and vapors contained in fluids. Initial filtration of a known volume of the fluid sample is combined with laser-induced dielectric breakdown spectroscopy of the filter employed to obtain qualitative and quantitative information with high sensitivity. Application of the invention to monitoring of beryllium, beryllium oxide, or other beryllium-alloy dusts is demonstrated. Significant shortening of analysis time is achieved from those of the usual chemical techniques of analysis.
Apparatus and method for quantitative determination of materials contained in fluids
Radziemski, L.J.; Cremers, D.A.
1982-09-07
Apparatus and method for near real-time in-situ monitoring of particulates and vapors contained in fluids are described. Initial filtration of a known volume of the fluid sample is combined with laser-induced dielectric breakdown spectroscopy of the filter employed to obtain qualitative and quantitative information with high sensitivity. Application of the invention to monitoring of beryllium, beryllium oxide, or other beryllium-alloy dusts is shown. Significant shortening of analysis time is achieved from the usual chemical techniques of analysis.
Development of a cloud-based system for remote monitoring of a PVT panel
NASA Astrophysics Data System (ADS)
Saraiva, Luis; Alcaso, Adérito; Vieira, Paulo; Ramos, Carlos Figueiredo; Cardoso, Antonio Marques
2016-10-01
The paper presents a monitoring system developed for an energy conversion system based on the sun and known as thermophotovoltaic panel (PVT). The project was implemented using two embedded microcontrollers platforms (arduino Leonardo and arduino yún), wireless transmission systems (WI-FI and XBEE) and net computing ,commonly known as cloud (Google cloud). The main objective of the project is to provide remote access and real-time data monitoring (like: electrical current, electrical voltage, input fluid temperature, output fluid temperature, backward fluid temperature, up PV glass temperature, down PV glass temperature, ambient temperature, solar radiation, wind speed, wind direction and fluid mass flow). This project demonstrates the feasibility of using inexpensive microcontroller's platforms and free internet service in theWeb, to support the remote study of renewable energy systems, eliminating the acquisition of dedicated systems typically more expensive and limited in the kind of processing proposed.
Method of measuring the mass flow rate of a substance entering a cocurrent fluid stream
Cochran, Jr., Henry D.
1978-04-11
This invention relates to an improved method of monitoring the mass flow rate of a substance entering a cocurrent fluid stream. The method very basically consists of heating equal sections of the fluid stream above and below the point of entry of the substance to be monitored, and measuring and comparing the resulting change in temperature of the sections. Advantage is taken of the difference in thermal characteristics of the fluid and the substance to be measured to correlate temperature differences in the sections above and below the substance feed point for providing an indication of the mass flow rate of the substance.
Goloshubin, Gennady M.; Korneev, Valeri A.
2006-11-14
A method for identifying, imaging and monitoring dry or fluid-saturated underground reservoirs using seismic waves reflected from target porous or fractured layers is set forth. Seismic imaging the porous or fractured layer occurs by low pass filtering of the windowed reflections from the target porous or fractured layers leaving frequencies below low-most corner (or full width at half maximum) of a recorded frequency spectra. Additionally, the ratio of image amplitudes is shown to be approximately proportional to reservoir permeability, viscosity of fluid, and the fluid saturation of the porous or fractured layers.
Goloshubin, Gennady M.; Korneev, Valeri A.
2005-09-06
A method for identifying, imaging and monitoring dry or fluid-saturated underground reservoirs using seismic waves reflected from target porous or fractured layers is set forth. Seismic imaging the porous or fractured layer occurs by low pass filtering of the windowed reflections from the target porous or fractured layers leaving frequencies below low-most corner (or full width at half maximum) of a recorded frequency spectra. Additionally, the ratio of image amplitudes is shown to be approximately proportional to reservoir permeability, viscosity of fluid, and the fluid saturation of the porous or fractured layers.
30 CFR 250.457 - What equipment is required to monitor drilling fluids?
Code of Federal Regulations, 2011 CFR
2011-07-01
... ENFORCEMENT, DEPARTMENT OF THE INTERIOR OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Oil and Gas Drilling Operations Drilling Fluid Requirements § 250.457 What equipment is required... 30 Mineral Resources 2 2011-07-01 2011-07-01 false What equipment is required to monitor drilling...
Meixler, Lewis D.
1993-01-01
The low flow monitor provides a means for determining if a fluid flow meets a minimum threshold level of flow. The low flow monitor operates with a minimum of intrusion by the flow detection device into the flow. The electrical portion of the monitor is externally located with respect to the fluid stream which allows for repairs to the monitor without disrupting the flow. The electronics provide for the adjustment of the threshold level to meet the required conditions. The apparatus can be modified to provide an upper limit to the flow monitor by providing for a parallel electronic circuit which provides for a bracketing of the desired flow rate.
Ito, N; Kayashima, S; Kimura, J; Kuriyama, T; Arai, T; Kikuchi, M; Nagata, N
1994-05-01
The paper describes a method for the transcutaneous monitoring of blood constituents. It combines the use of a suction effusion fluid (SEF) collecting technique with a silicon on sapphire/ion-sensitive field-effect transistor (SOS/ISFET) biosensor. SEF is directly collected by a weak evacuation through skin from which the stratum corneum has been removed. An SEF collecting cell with a stainless-steel mesh at the bottom is kept in a weak vacuum condition, and SEF is sucked up through the mesh and deposited in a reservoir above. An ISFET glucose sensor is able to detect glucose concentrations in very small SEF samples through the use of two small ISFETs and an immobilised enzyme membrane. The reliability of transcutaneously obtained SEF was first confirmed in an experiment using rabbits. A clinical analyser was used to determine levels of glucose, urea nitrogen and creatinine in SEF obtained transcutaneously; these results are compared with results obtained by the same analyser directly from sera. The ISFET glucose sensor was successfully tested on human subjects for the monitoring of blood glucose levels. During these tests, glucose level changes in the SEF followed actual blood glucose level changes with a slight time delay. Results suggest the feasibility of non-invasive, transcutaneous monitoring of low molecular weight substances in the blood without the use of ordinary blood sampling.
Slip behaviour of carbonate-bearing faults subjected to fluid pressure stimulations
NASA Astrophysics Data System (ADS)
Collettini, Cristiano; Scuderi, Marco; Marone, Chris
2017-04-01
Earthquakes caused by fluid injection within reservoir have become an important topic of political and social discussion as new drilling and improved technologies enable the extraction of oil and gas from previously unproductive formations. During reservoir stimulation, the coupled interactions of frictional and fluid flow properties together with the stress state control both the onset of fault slip and fault slip behaviour. However, currently, there are no studies under controlled, laboratory conditions for which the effect of fluid pressure on fault slip behaviour can be deduced. To cover this gap, we have developed laboratory experiments where we monitor fault slip evolution at constant shear stress but with increasing fluid pressure, i.e. reducing the effective normal stress. Experiments have been conducted in the double direct shear configuration within a pressure vessel on carbonate fault gouge, characterized by a slightly velocity strengthening friction that is indicative of stable aseismic creep. In our experiments fault slip history can be divided in three main stages: 1) for high effective normal stress the fault is locked and undergoes compaction; 2) when the shear and effective normal stress reach the failure condition, accelerated creep is associated to fault dilation; 3) further pressurization leads to an exponential acceleration during fault compaction and slip localization. Our results indicate that fault weakening induced by fluid pressurization overcomes the velocity strengthening behaviour of calcite gouge, resulting in fast acceleration and earthquake slip. As applied to tectonic faults our results suggest that a larger number of crustal faults, including those slightly velocity strengthening, can experience earthquake slip due to fluid pressurization.
Brachmann, Johannes; Böhm, Michael; Rybak, Karin; Klein, Gunnar; Butter, Christian; Klemm, Hanno; Schomburg, Rolf; Siebermair, Johannes; Israel, Carsten; Sinha, Anil-Martin; Drexler, Helmut
2011-01-01
Aims The Optimization of Heart Failure Management using OptiVol Fluid Status Monitoring and CareLink (OptiLink HF) study is designed to investigate whether OptiVol fluid status monitoring with an automatically generated wireless CareAlert notification via the CareLink Network can reduce all-cause death and cardiovascular hospitalizations in an HF population, compared with standard clinical assessment. Methods Patients with newly implanted or replacement cardioverter-defibrillator devices with or without cardiac resynchronization therapy, who have chronic HF in New York Heart Association class II or III and a left ventricular ejection fraction ≤35% will be eligible to participate. Following device implantation, patients are randomized to either OptiVol fluid status monitoring through CareAlert notification or regular care (OptiLink ‘on' vs. ‘off'). The primary endpoint is a composite of all-cause death or cardiovascular hospitalization. It is estimated that 1000 patients will be required to demonstrate superiority of the intervention group to reduce the primary outcome by 30% with 80% power. Conclusion The OptiLink HF study is designed to investigate whether early detection of congestion reduces mortality and cardiovascular hospitalization in patients with chronic HF. The study is expected to close recruitment in September 2012 and to report first results in May 2014. ClinicalTrials.gov Identifier: NCT00769457 PMID:21555324
Lee, Min-Jeong; Seo, Da-Young; Lee, Hea-Eun; Wang, In-Chun; Kim, Woo-Sik; Jeong, Myung-Yung; Choi, Guang J
2011-01-17
Along with the risk-based approach, process analytical technology (PAT) has emerged as one of the key elements to fully implement QbD (quality-by-design). Near-infrared (NIR) spectroscopy has been extensively applied as an in-line/on-line analytical tool in biomedical and chemical industries. In this study, the film thickness on pharmaceutical pellets was examined for quantification using in-line NIR spectroscopy during a fluid-bed coating process. A precise monitoring of coating thickness and its prediction with a suitable control strategy is crucial to the quality assurance of solid dosage forms including dissolution characteristics. Pellets of a test formulation were manufactured and coated in a fluid-bed by spraying a hydroxypropyl methylcellulose (HPMC) coating solution. NIR spectra were acquired via a fiber-optic probe during the coating process, followed by multivariate analysis utilizing partial least squares (PLS) calibration models. The actual coating thickness of pellets was measured by two separate methods, confocal laser scanning microscopy (CLSM) and laser diffraction particle size analysis (LD-PSA). Both characterization methods gave superb correlation results, and all determination coefficient (R(2)) values exceeded 0.995. In addition, a prediction coating experiment for 70min demonstrated that the end-point can be accurately designated via NIR in-line monitoring with appropriate calibration models. In conclusion, our approach combining in-line NIR monitoring with CLSM and LD-PSA can be applied as an effective PAT tool for fluid-bed pellet coating processes. Copyright © 2010 Elsevier B.V. All rights reserved.
Oscillatory hydraulic testing as a strategy for NAPL source zone monitoring: Laboratory experiments
NASA Astrophysics Data System (ADS)
Zhou, YaoQuan; Cardiff, Michael
2017-05-01
Non-aqueous phase liquids (NAPLs) have a complex mode of transport in heterogeneous aquifers, which can result in pools and lenses of NAPLs (the "source zone") that are difficult to detect and can cause long-term contamination via slow dissolution into groundwater (the "dissolved plume"). Characterizing the extent and evolution of NAPL contamination within the source zone is a useful strategy for designing and adapting appropriate remedial actions at many contaminated sites. As a NAPL flows into a given aquifer volume, the effective hydraulic conductivity (K) and specific storage (Ss) of the volume changes associated with the viscosity and compressibility of the impinging fluid, meaning that NAPL movement may be detectable with hydraulic testing. Recently, the use of oscillatory pumping tests - in which sinusoidal pumping variations are implemented and oscillatory pressure changes are detected at monitoring locations - has been suggested as a low-impact hydraulic testing strategy for characterizing aquifer properties (Cardiff et al., 2013; Zhou et al., 2016). Here, we investigate this strategy in an experimental laboratory sandbox where dyed vegetable oil is injected and allowed to migrate as a NAPL. Initial qualitative analyses demonstrate that measurable changes in pressure signal amplitude and phase provide clear evidence for NAPL plume emplacement and migration. Using the approach developed in Zhou et al. (2016), we then apply tomographic analyses to estimate the location of effective K changes (representing fluid changes) and their movement throughout time. This approach provides a method for monitoring ongoing NAPL movement without net extraction or injection of fluid, making it advantageous in field remediation applications.
NASA Technical Reports Server (NTRS)
Grimes, C. A.; Kouzoudis, D.
2000-01-01
Free-standing magnetoelastic thick-film sensors have a characteristic resonant frequency that can be determined by monitoring the magnetic flux emitted from the sensor in response to a time varying magnetic field. This property allows the sensors to be monitored remotely without the use of direct physical connections, such as wires, enabling measurement of environmental parameters from within sealed, opaque containers. In this work, we report on application of magnetoelastic sensors to measurement of atmospheric pressure, fluid-flow velocity, temperature, and mass load. Mass loading effects are demonstrated by fabrication of a remote query humidity sensor, made by coating the magnetoelastic thick film with a thin layer of solgel deposited Al2O3 that reversibly changes mass in response to humidity. c2000 Elsevier Science S.A. All rights reserved.
Camera on Vessel: A Camera-Based System to Measure Change in Water Volume in a Drinking Glass.
Ayoola, Idowu; Chen, Wei; Feijs, Loe
2015-09-18
A major problem related to chronic health is patients' "compliance" with new lifestyle changes, medical prescriptions, recommendations, or restrictions. Heart-failure and hemodialysis patients are usually placed on fluid restrictions due to their hemodynamic status. A holistic approach to managing fluid imbalance will incorporate the monitoring of salt-water intake, body-fluid retention, and fluid excretion in order to provide effective intervention at an early stage. Such an approach creates a need to develop a smart device that can monitor the drinking activities of the patient. This paper employs an empirical approach to infer the real water level in a conically shapped glass and the volume difference due to changes in water level. The method uses a low-resolution miniaturized camera to obtain images using an Arduino microcontroller. The images are processed in MATLAB. Conventional segmentation techniques (such as a Sobel filter to obtain a binary image) are applied to extract the level gradient, and an ellipsoidal fitting helps to estimate the size of the cup. The fitting (using least-squares criterion) between derived measurements in pixel and the real measurements shows a low covariance between the estimated measurement and the mean. The correlation between the estimated results to ground truth produced a variation of 3% from the mean.
Camera on Vessel: A Camera-Based System to Measure Change in Water Volume in a Drinking Glass
Ayoola, Idowu; Chen, Wei; Feijs, Loe
2015-01-01
A major problem related to chronic health is patients’ “compliance” with new lifestyle changes, medical prescriptions, recommendations, or restrictions. Heart-failure and hemodialysis patients are usually placed on fluid restrictions due to their hemodynamic status. A holistic approach to managing fluid imbalance will incorporate the monitoring of salt-water intake, body-fluid retention, and fluid excretion in order to provide effective intervention at an early stage. Such an approach creates a need to develop a smart device that can monitor the drinking activities of the patient. This paper employs an empirical approach to infer the real water level in a conically shapped glass and the volume difference due to changes in water level. The method uses a low-resolution miniaturized camera to obtain images using an Arduino microcontroller. The images are processed in MATLAB. Conventional segmentation techniques (such as a Sobel filter to obtain a binary image) are applied to extract the level gradient, and an ellipsoidal fitting helps to estimate the size of the cup. The fitting (using least-squares criterion) between derived measurements in pixel and the real measurements shows a low covariance between the estimated measurement and the mean. The correlation between the estimated results to ground truth produced a variation of 3% from the mean. PMID:26393600
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Jihoon; Um, Evan; Moridis, George
2014-12-01
We investigate fracture propagation induced by hydraulic fracturing with water injection, using numerical simulation. For rigorous, full 3D modeling, we employ a numerical method that can model failure resulting from tensile and shear stresses, dynamic nonlinear permeability, leak-off in all directions, and thermo-poro-mechanical effects with the double porosity approach. Our numerical results indicate that fracture propagation is not the same as propagation of the water front, because fracturing is governed by geomechanics, whereas water saturation is determined by fluid flow. At early times, the water saturation front is almost identical to the fracture tip, suggesting that the fracture is mostlymore » filled with injected water. However, at late times, advance of the water front is retarded compared to fracture propagation, yielding a significant gap between the water front and the fracture top, which is filled with reservoir gas. We also find considerable leak-off of water to the reservoir. The inconsistency between the fracture volume and the volume of injected water cannot properly calculate the fracture length, when it is estimated based on the simple assumption that the fracture is fully saturated with injected water. As an example of flow-geomechanical responses, we identify pressure fluctuation under constant water injection, because hydraulic fracturing is itself a set of many failure processes, in which pressure consistently drops when failure occurs, but fluctuation decreases as the fracture length grows. We also study application of electromagnetic (EM) geophysical methods, because these methods are highly sensitive to changes in porosity and pore-fluid properties due to water injection into gas reservoirs. Employing a 3D finite-element EM geophysical simulator, we evaluate the sensitivity of the crosswell EM method for monitoring fluid movements in shaly reservoirs. For this sensitivity evaluation, reservoir models are generated through the coupled flow-geomechanical simulator and are transformed via a rock-physics model into electrical conductivity models. It is shown that anomalous conductivity distribution in the resulting models is closely related to injected water saturation, but not closely related to newly created unsaturated fractures. Our numerical modeling experiments demonstrate that the crosswell EM method can be highly sensitive to conductivity changes that directly indicate the migration pathways of the injected fluid. Accordingly, the EM method can serve as an effective monitoring tool for distribution of injected fluids (i.e., migration pathways) during hydraulic fracturing operations« less
Time-Lapse Electrical Geophysical Monitoring of Amendment-Based Biostimulation.
Johnson, Timothy C; Versteeg, Roelof J; Day-Lewis, Frederick D; Major, William; Lane, John W
2015-01-01
Biostimulation is increasingly used to accelerate microbial remediation of recalcitrant groundwater contaminants. Effective application of biostimulation requires successful emplacement of amendment in the contaminant target zone. Verification of remediation performance requires postemplacement assessment and contaminant monitoring. Sampling-based approaches are expensive and provide low-density spatial and temporal information. Time-lapse electrical resistivity tomography (ERT) is an effective geophysical method for determining temporal changes in subsurface electrical conductivity. Because remedial amendments and biostimulation-related biogeochemical processes often change subsurface electrical conductivity, ERT can complement and enhance sampling-based approaches for assessing emplacement and monitoring biostimulation-based remediation. Field studies demonstrating the ability of time-lapse ERT to monitor amendment emplacement and behavior were performed during a biostimulation remediation effort conducted at the Department of Defense Reutilization and Marketing Office (DRMO) Yard, in Brandywine, Maryland, United States. Geochemical fluid sampling was used to calibrate a petrophysical relation in order to predict groundwater indicators of amendment distribution. The petrophysical relations were field validated by comparing predictions to sequestered fluid sample results, thus demonstrating the potential of electrical geophysics for quantitative assessment of amendment-related geochemical properties. Crosshole radar zero-offset profile and borehole geophysical logging were also performed to augment the data set and validate interpretation. In addition to delineating amendment transport in the first 10 months after emplacement, the time-lapse ERT results show later changes in bulk electrical properties interpreted as mineral precipitation. Results support the use of more cost-effective surface-based ERT in conjunction with limited field sampling to improve spatial and temporal monitoring of amendment emplacement and remediation performance. Published 2014. This article is a U.S. Government work and is in the public domain in the USA.
1977-10-01
16th June, 1975. Panorama , BBC TV. 5) R.H. Ellis Air Defence of the West - a view from NATC’S central (Genl.) region. 15th Anglo-American Aero...monitor the studies which are undertaken, MoD formed a Thermal Effects on Aircraft Conventional Armament, Stores and Equipment (TEACASE) Working Group. The...Suitable body dimension (ft) k - Thermal conductivity of the fluid The Prantl No. (Pr) is given by: Pr C where 3 a Viscosity of the fluid Cp = Specific
NASA Technical Reports Server (NTRS)
Regalado Reyes, Bjorn Constant
2015-01-01
1. Kennedy Space Center (KSC) is developing a mobile launching system with autonomous propellant loading capabilities for liquid-fueled rockets. An autonomous system will be responsible for monitoring and controlling the storage, loading and transferring of cryogenic propellants. The Physics Simulation Software will reproduce the sensor data seen during the delivery of cryogenic fluids including valve positions, pressures, temperatures and flow rates. The simulator will provide insight into the functionality of the propellant systems and demonstrate the effects of potential faults. This will provide verification of the communications protocols and the autonomous system control. 2. The High Pressure Gas Facility (HPGF) stores and distributes hydrogen, nitrogen, helium and high pressure air. The hydrogen and nitrogen are stored in cryogenic liquid state. The cryogenic fluids pose several hazards to operators and the storage and transfer equipment. Constant monitoring of pressures, temperatures and flow rates are required in order to maintain the safety of personnel and equipment during the handling and storage of these commodities. The Gas House Autonomous System Monitoring software will be responsible for constantly observing and recording sensor data, identifying and predicting faults and relaying hazard and operational information to the operators.
Srivastava, Divya; Sahu, Sandeep; Chandra, Abhilash; Tiwari, Tanmay; Kumar, Sanjay; Singh, P K
2015-12-01
Transesophageal Doppler (TED)-guided intraoperative fluid therapy has shown to noninvasively optimize intravascular volume and reduce postoperative morbidity. The aim of this study was to compare the effects of Doppler-guided intraoperative fluid administration and central venous pressure (CVP)-guided fluid therapy on renal allograft outcome and postoperative complications. A prospective nonrandomized active controlled study was conducted on end-stage renal disease patients scheduled for living donor renal transplant surgery. 110 patients received intraoperative fluid guided by corrected flow time (FTc) and variation in stroke volume values obtained by continuous TED monitoring. Data of 104 patients in whom intraoperative fluid administration was guided by CVP values were retrospectively obtained for a control. The amount of intraoperative fluid given in the study group (12.20 ± 4.24 ml/kg/h) was significantly lower than in the controls (22.21 ± 4.67 ml/kg/h). The amount of colloid used was also significantly less and fewer recipients were seen to require colloid (69 vs 85%). The mean arterial pressures were comparable throughout. CVP reached was 7.18 ± 3.17 mmHg in the study group. It was significantly higher in the controls (13.42 ± 3.12 mmHg). The postoperative graft function and rate of dysfunction were comparable. Side-effects like postoperative dyspnoea (4.8 vs 0%) and tissue edema (9.6 vs 2.7%) were higher in the controls. FTc-guided intraoperative fluid therapy achieved the same rate of immediate graft function as CVP-guided fluid therapy but used a significantly less amount of fluid. The incidence of postoperative complications related to fluid overload was also reduced. The use of TED may replace invasive central line insertions in the future.
Monitoring probe for groundwater flow
Looney, Brian B.; Ballard, Sanford
1994-01-01
A monitoring probe for detecting groundwater migration. The monitor features a cylinder made of a permeable membrane carrying an array of electrical conductivity sensors on its outer surface. The cylinder is filled with a fluid that has a conductivity different than the groundwater. The probe is placed in the ground at an area of interest to be monitored. The fluid, typically saltwater, diffuses through the permeable membrane into the groundwater. The flow of groundwater passing around the permeable membrane walls of the cylinder carries the conductive fluid in the same general direction and distorts the conductivity field measured by the sensors. The degree of distortion from top to bottom and around the probe is precisely related to the vertical and horizontal flow rates, respectively. The electrical conductivities measured by the sensors about the outer surface of the probe are analyzed to determine the rate and direction of the groundwater flow.
Monitoring probe for groundwater flow
Looney, B.B.; Ballard, S.
1994-08-23
A monitoring probe for detecting groundwater migration is disclosed. The monitor features a cylinder made of a permeable membrane carrying an array of electrical conductivity sensors on its outer surface. The cylinder is filled with a fluid that has a conductivity different than the groundwater. The probe is placed in the ground at an area of interest to be monitored. The fluid, typically saltwater, diffuses through the permeable membrane into the groundwater. The flow of groundwater passing around the permeable membrane walls of the cylinder carries the conductive fluid in the same general direction and distorts the conductivity field measured by the sensors. The degree of distortion from top to bottom and around the probe is precisely related to the vertical and horizontal flow rates, respectively. The electrical conductivities measured by the sensors about the outer surface of the probe are analyzed to determine the rate and direction of the groundwater flow. 4 figs.
The effect of the pore-fluid factor on strength and failure mechanism of Wilkeson sandstone
NASA Astrophysics Data System (ADS)
Kätker, A. K.; Rempe, M.; Renner, J.
2016-12-01
The effective stress law, σn,eff = σn - αpf, is a central tool in analysing phenomena related to hydromechanical coupling, such as fluid-induced seismicity or aftershock activity. The effective-stress coefficient α assumes different values for specific physical properties and may deviate from 1. The limited number of studies suggest that brittle compressive strength obeys an effective-stress law when effective drainage is achieved. Yet, open questions remain regarding, e.g., the role of the loading path. We performed suites of triaxial compression tests on samples of Wilkeson sandstone at a range of pore-fluid pressures but identical effective confining pressure (60, 100, and 120 MPa) maintaining the pore-fluid factor λ = pf / pc constant (0.05, 0.2, 0.4, 0.55) during the isostatic loading stage to ensure uniform loading paths. Samples were shortened with a strain rate of 4×10-7 s-1 yielding drained conditions. All tests were terminated at a total axial strain of 4.5% for comparability of microstructures. The tests also included continuous permeability determination and ultrasonic p-wave-velocity measurements to monitor microstructural evolution. Results from experiments conducted at peff = 100 MPa show that dry samples exhibit a higher peak strength and brittle failure while water-saturated samples tend to deform at lower stress by cataclastic flow indicating physico-chemical weakening. Regardless of pore-fluid factor, the saturated experiments exhibit similar peak and residual strength. Differences in failure mechanism (degree of macroscopic localization) and volumetric strain evolution are however noticed, albeit without systematic relation to pore-fluid factor. Microstructure analyses by optical and scanning electron microscopy revealed an evolution from localized shear zones in dry experiments and experiments with a low pore-fluid factor to rather distributed cataclastic flow for experiments with high pore fluid factors. Yet, mechanical and structural differences observed so far may result from sample-to-sample variability and the proximity of the experimental conditions to the brittle-ductile transition.
Method and apparatus for monitoring and measuring the surface tension of a fluid using fiber optics
Abraham, Bernard M.; Ketterson, John B.; Bohanon, Thomas M.; Mikrut, John M.
1994-01-01
A non-contact method and apparatus for measuring and monitoring the surface of a fluid using fiber optics and interferometric detection to permit measurement mechanical characteristics' fluid surfaces. The apparatus employs an alternating electric field gradient for generating a capillary wave on the surface of the fluid. A fiber optic coupler and optical fiber directs a portion of a laser beam onto the surface of the fluid, another portion of the laser beam onto the photo sensor, and directs light reflected from the surface of the fluid onto the photo sensor. The output of the photo sensor is processed and coupled to a phase sensitive detector to permit measurement of phase shift between the drive signal creating the capillary wave and the detected signal. This phase shift information is then used to determine mechanical properties of the fluid surface such as surface tension, surface elasticity, and surface inhomogeneity. The resulting test structure is easily made compact, portable, and easy to align and use.
Soenksen, L R; Kassis, T; Noh, M; Griffith, L G; Trumper, D L
2018-03-13
Precise fluid height sensing in open-channel microfluidics has long been a desirable feature for a wide range of applications. However, performing accurate measurements of the fluid level in small-scale reservoirs (<1 mL) has proven to be an elusive goal, especially if direct fluid-sensor contact needs to be avoided. In particular, gravity-driven systems used in several microfluidic applications to establish pressure gradients and impose flow remain open-loop and largely unmonitored due to these sensing limitations. Here we present an optimized self-shielded coplanar capacitive sensor design and automated control system to provide submillimeter fluid-height resolution (∼250 μm) and control of small-scale open reservoirs without the need for direct fluid contact. Results from testing and validation of our optimized sensor and system also suggest that accurate fluid height information can be used to robustly characterize, calibrate and dynamically control a range of microfluidic systems with complex pumping mechanisms, even in cell culture conditions. Capacitive sensing technology provides a scalable and cost-effective way to enable continuous monitoring and closed-loop feedback control of fluid volumes in small-scale gravity-dominated wells in a variety of microfluidic applications.
Coolant monitoring apparatus for nuclear reactors
Tokarz, Richard D.
1983-01-01
A system for monitoring coolant conditions within a pressurized vessel. A length of tubing extends outward from the vessel from an open end containing a first line restriction at the location to be monitored. The flowing fluid is cooled and condensed before passing through a second line restriction. Measurement of pressure drop at the second line restriction gives an indication of fluid condition at the first line restriction. Multiple lengths of tubing with open ends at incremental elevations can measure coolant level within the vessel.
Detecting subsurface fluid leaks in real-time using injection and production rates
NASA Astrophysics Data System (ADS)
Singh, Harpreet; Huerta, Nicolas J.
2017-12-01
CO2 injection into geologic formations for either enhanced oil recovery or carbon storage introduces a risk for undesired fluid leakage into overlying groundwater or to the surface. Despite decades of subsurface CO2 production and injection, the technologies and methods for detecting CO2 leaks are still costly and prone to large uncertainties. This is especially true for pressure-based monitoring methods, which require the use of simplified geological and reservoir flow models to simulate the pressure behavior as well as background noise affecting pressure measurements. In this study, we propose a method to detect the time and volume of fluid leakage based on real-time measurements of well injection and production rates. The approach utilizes analogies between fluid flow and capacitance-resistance modeling. Unlike other leak detection methods (e.g. pressure-based), the proposed method does not require geological and reservoir flow models to simulate the behavior that often carry significant sources of uncertainty; therefore, with our approach the leak can be detected with greater certainty. The method can be applied to detect when a leak begins by tracking a departure in fluid production rate from the expected pattern. The method has been tuned to detect the effect of boundary conditions and fluid compressibility on leakage. To highlight the utility of this approach we use our method to detect leaks for two scenarios. The first scenario simulates a fluid leak from the storage formation into an above-zone monitoring interval. The second scenario simulates intra-reservoir migration between two compartments. We illustrate this method to detect fluid leakage in three different reservoirs with varying levels of geological and structural complexity. The proposed leakage detection method has three novelties: i) requires only readily-available data (injection and production rates), ii) accounts for fluid compressibility and boundary effects, and iii) in addition to detecting the time when a leak is activated and the volume of that leakage, this method provides an insight about the leak location, and reservoir connectivity. We are proposing this as a complementary method that can be used with other, more expensive, methods early on in the injection process. This will allow an operator to conduct more expensive surveys less often because the proposed method can show if there are no leaks on a monthly basis that is cheap and fast.
Electrical Resistance Tomography Field Trials to Image CO2 Sequestration
NASA Astrophysics Data System (ADS)
Newmark, R.
2003-12-01
If geologic formations are used to sequester or store carbon dioxide (CO2) for long periods of time, it will be necessary to verify the containment of injected CO2 by assessing leaks and flow paths, and by understanding the geophysical and geochemical interactions between the CO2 and the geologic minerals and fluids. Remote monitoring methods are preferred, to minimize cost and impact to the integrity of the disposal reservoir. Electrical methods are especially well suited for monitoring processes involving fluids, as electrical properties are most sensitive to the presence and nature of the fluids contained in the medium. High resolution tomographs of electrical properties have been used with success for site characterization, monitoring subsurface migration of fluids in instances of leaking underground tanks, water infiltration events, subsurface steam floods, contaminant movement, and assessing the integrity of subsurface barriers. These surveys are commonly conducted utilizing vertical arrays of point electrodes in a crosswell configuration. Alternative ways of monitoring the reservoir are desirable due to the high costs of drilling the required monitoring boreholes Recent field results obtained using steel well casings as long electrodes are also promising. We have conducted field trials to evaluate the effectiveness of long electrode ERT as a potential monitoring approach for CO2 sequestration. In these trials, CO2 is not being sequestered but rather is being used as a solvent for enhanced oil recovery. This setting offers the same conditions expected during sequestration so monitoring secondary oil recovery allows a test of the method under realistic physical conditions and operational constraints. Field experience has confirmed the challenges identified during model studies. The principal difficulty are the very small signals due to the fact that formation changes occur only over a small segment of the 5000 foot length of the electrodes. In addition, telluric noise can be comparable to the signal levels during periods of geomagnetic activity. Finally, instrumentation stability over long periods is necessary to follow trends in reservoir behavior for several years. Solutions to these and other problems will be presented along with results from the first two years of work at a producing field undergoing CO2 flood. If electrical resistance tomography (ERT) imaging can be performed using existing well casings as long electrodes, it will substantially reduce the cost to monitor CO2 sequestration. This work was performed under the auspices of the U.S. Department of Energy by University of California Lawrence Livermore National Laboratory under contract No. W-7405-Eng-48.
USDA-ARS?s Scientific Manuscript database
Electropenetrography (EPG) waveforms represent electrical conductivity of fluids flowing through an insect’s mouthparts. Over the 50 years since its invention, EPG has undergone three major electronic transformations. The newest, third generation of electropenetrograph, the AC-DC EPG monitor, offers...
Park, Yoo-Sin; Kim, Shin-Hee; Kim, Sang-Hyun; Jun, Min-Young
2011-01-01
Epilepsy is a chronic disease occurring in approximately 1.0% of the world's population. About 30% of the epileptic patients treated with availably antiepileptic drugs (AEDs) continue to have seizures and are considered therapy-resistant or refractory patients. The ultimate goal for the use of AEDs is complete cessation of seizures without side effects. Because of a narrow therapeutic index of AEDs, a complete understanding of its clinical pharmacokinetics is essential for understanding of the pharmacodynamics of these drugs. These drug concentrations in biological fluids serve as surrogate markers and can be used to guide or target drug dosing. Because early studies demonstrated clinical and/or electroencephalographic correlations with serum concentrations of several AEDs, It has been almost 50 years since clinicians started using plasma concentrations of AEDs to optimize pharmacotherapy in patients with epilepsy. Therefore, validated analytical method for concentrations of AEDs in biological fluids is a necessity in order to explore pharmacokinetics, bioequivalence and TDM in various clinical situations. There are hundreds of published articles on the analysis of specific AEDs by a wide variety of analytical methods in biological samples have appears over the past decade. This review intends to provide an updated, concise overview on the modern method development for monitoring AEDs for pharmacokinetic studies, bioequivalence and therapeutic drug monitoring. PMID:21660146
Seismic characteristics of tensile fracture growth induced by hydraulic fracturing
NASA Astrophysics Data System (ADS)
Eaton, D. W. S.; Van der Baan, M.; Boroumand, N.
2014-12-01
Hydraulic fracturing is a process of injecting high-pressure slurry into a rockmass to enhance its permeability. Variants of this process are used for unconventional oil and gas development, engineered geothermal systems and block-cave mining; similar processes occur within volcanic systems. Opening of hydraulic fractures is well documented by mineback trials and tiltmeter monitoring and is a physical requirement to accommodate the volume of injected fluid. Numerous microseismic monitoring investigations acquired in the audio-frequency band are interpreted to show a prevalence of shear-dominated failure mechanisms surrounding the tensile fracture. Moreover, the radiated seismic energy in the audio-frequency band appears to be a miniscule fraction (<< 1%) of the net injected energy, i.e., the integral of the product of fluid pressure and injection rate. We use a simple penny-shaped crack model as a predictive framework to describe seismic characteristics of tensile opening during hydraulic fracturing. This model provides a useful scaling relation that links seismic moment to effective fluid pressure within the crack. Based on downhole recordings corrected for attenuation, a significant fraction of observed microseismic events are characterized by S/P amplitude ratio < 5. Despite the relatively small aperture of the monitoring arrays, which precludes both full moment-tensor analysis and definitive identification of nodal planes or axes, this ratio provides a strong indication that observed microseismic source mechanisms have a component of tensile failure. In addition, we find some instances of periodic spectral notches that can be explained by an opening/closing failure mechanism, in which fracture propagation outpaces fluid velocity within the crack. Finally, aseismic growth of tensile fractures may be indicative of a scenario in which injected energy is consumed to create new fracture surfaces. Taken together, our observations and modeling provide evidence that failure mechanisms documented by passive monitoring of hydraulic fractures may contain a significant component of tensile failure, including fracture opening and closing, although creation of extensive new fracture surfaces may be a seismically inefficient process that radiates at sub-audio frequencies.
Multi-channel electrical impedance tomography for regional tissue hydration monitoring.
Chen, Xiaohui; Kao, Tzu-Jen; Ashe, Jeffrey M; Boverman, Gregory; Sabatini, James E; Davenport, David M
2014-06-01
Poor assessment of hydration status during hemodialysis can lead to under- or over-hydration in patients with consequences of increased morbidity and mortality. In current practice, fluid management is largely based on clinical assessments to estimate dry weight (normal hydration body weight). However, hemodialysis patients usually have co-morbidities that can make the signs of fluid status ambiguous. Therefore, achieving normal hydration status remains a major challenge for hemodialysis therapy. Electrical impedance technology has emerged as a promising method for hydration monitoring due to its non-invasive nature, low cost and ease-of-use. Conventional electrical impedance-based hydration monitoring systems employ single-channel current excitation (either 2-electrode or 4-electrode methods) to perturb and extract averaged impedance from bulk tissue and use generalized models from large populations to derive hydration estimates. In the present study, a prototype, single-frequency electrical impedance tomography (EIT) system with simultaneous multi-channel current excitation was used to enable regional hydration change detection. We demonstrated the capability to detect a difference in daily impedance change between left leg and right leg in healthy human subjects, who wore a compression sock only on one leg to reduce daily gravitational fluid accumulation. The impedance difference corresponded well with the difference of lower leg volume change between left leg and right leg measured by volumetry, which on average is ~35 ml, accounting for 0.7% of the lower leg volume. We have demonstrated the feasibility of using multi-channel EIT to extract hydration information in different tissue layers with minimal skin interference. Our simultaneous, multi-channel current excitation approach provides an effective method to separate electrode contact impedance and skin condition artifacts from hydration signals. The prototype system has the potential to be used in clinical settings for helping optimize patient fluid management during hemodialysis as well as for home monitoring of patients with congestive heart failure, chronic kidney disease, diabetes and other diseases with peripheral edema symptoms.
NASA Technical Reports Server (NTRS)
Baughman, J. R.; Thys, P. C.
1973-01-01
A droplet monitoring system is disclosed for analysis of mixed-phase fluid flow in development of gas turbines. The system uses a probe comprising two electrical wires spaced a known distance apart and connected at one end to means for establishing a dc potential between the wires. A drop in the fluid stream momentarily contacting both wires simultaneously causes and electrical signal which is amplified, detected and counted.
Conceptual design of intravenous fluids level monitoring system - a review
NASA Astrophysics Data System (ADS)
Verma, Prikshit; Padmani, Aniket; Boopathi, M.
2017-11-01
In today’s world of automation, there are advancements going on in all the fields. Each work is being automated day by day. However, if we see our current medical care system, some areas require manual caretaker and are loaded with heavy jobs, which consumes a lot of time. Nevertheless, since the work is related to human health, it should be properly done and that too with accuracy. An example of such a particular work is injecting saline or Intravenous (IV) fluids in a patient. The monitoring of such fluids needs utter attention as if the bottle of the fluid is not changed on time, it may lead to various problems for the patients like backflow of blood, blood loss etc. Various researches have been performed to overcome such critical situation. Different monitoring and alerting techniques are described in different researches. So, in our study, we will go through the researches done in this particular field and will see how different ideas are implemented.
Flow monitoring and control system for injection wells
Corey, John C.
1993-01-01
A system for monitoring and controlling the injection rate of fluid by an injection well of an in-situ remediation system for treating a contaminated groundwater plume. The well is fitted with a gated insert, substantially coaxial with the injection well. A plurality of openings, some or all of which are equipped with fluid flow sensors and gates, are spaced along the insert. The gates and sensors are connected to a surface controller. The insert may extend throughout part of, or substantially the entire length of the injection well. Alternatively, the insert may comprise one or more movable modules which can be positioned wherever desired along the well. The gates are opened part-way at the start of treatment. The sensors monitor and display the flow rate of fluid passing through each opening on a controller. As treatment continues, the gates are opened to increase flow in regions of lesser flow, and closed to decrease flow in regions of greater flow, thereby approximately equalizing the amount of fluid reaching each part of the plume.
Flow monitoring and control system for injection wells
Corey, J.C.
1993-02-16
A system for monitoring and controlling the injection rate of fluid by an injection well of an in-situ remediation system for treating a contaminated groundwater plume. The well is fitted with a gated insert, substantially coaxial with the injection well. A plurality of openings, some or all of which are equipped with fluid flow sensors and gates, are spaced along the insert. The gates and sensors are connected to a surface controller. The insert may extend throughout part of, or substantially the entire length of the injection well. Alternatively, the insert may comprise one or more movable modules which can be positioned wherever desired along the well. The gates are opened part-way at the start of treatment. The sensors monitor and display the flow rate of fluid passing through each opening on a controller. As treatment continues, the gates are opened to increase flow in regions of lesser flow, and closed to decrease flow in regions of greater flow, thereby approximately equalizing the amount of fluid reaching each part of the plume.
Detecting rapid mass movements using electrical self-potential measurements
NASA Astrophysics Data System (ADS)
Heinze, Thomas; Limbrock, Jonas; Pudasaini, Shiva P.; Kemna, Andreas
2017-04-01
Rapid mass movements are a latent danger for lives and infrastructure in almost any part of the world. Often such mass movements are caused by increasing pore pressure, for example, landslides after heavy rainfall or dam breaking after intrusion of water in the dam. Among several other geophysical methods used to observe water movement, the electrical self-potential method has been applied to a broad range of monitoring studies, especially focusing on volcanism and dam leakage but also during hydraulic fracturing and for earthquake prediction. Electrical self-potential signals may be caused by various mechanisms. Though, the most relevant source of the self-potential field in the given context is the streaming potential, caused by a flowing electrolyte through porous media with electrically charged internal surfaces. So far, existing models focus on monitoring water flow in non-deformable porous media. However, as the self-potential is sensitive to hydraulic parameters of the soil, any change in these parameters will cause an alteration of the electric signal. Mass movement will significantly influence the hydraulic parameters of the solid as well as the pressure field, assuming that fluid movement is faster than the pressure diffusion. We will present results of laboratory experiments under drained and undrained conditions with fluid triggered as well as manually triggered mass movements, monitored with self-potential measurements. For the undrained scenarios, we observe a clear correlation between the mass movements and signals in the electric potential, which clearly differ from the underlying potential variations due to increased saturation and fluid flow. In the drained experiments, we do not observe any measurable change in the electric potential. We therefore assume that change in fluid properties and release of the load causes disturbances in flow and streaming potential. We will discuss results of numerical simulations reproducing the observed effect. Our results indicate that electrical self-potential measurements can observe rapid mass movements when the movement is large and fast enough to disturb the fluid pressure field significantly.
Capacitive system detects and locates fluid leaks
NASA Technical Reports Server (NTRS)
1966-01-01
Electronic monitoring system automatically detects and locates minute leaks in seams of large fluid storage tanks and pipelines covered with thermal insulation. The system uses a capacitive tape-sensing element that is adhesively bonded over seams where fluid leaks are likely to occur.
Sanguinarine: A Novel Agent Against Prostate Cancer
2008-01-01
the possibility of treatment- toxicity , the effect of treatments on food/water consumption and body weight was monitored twice weekly throughout the...data not shown). Further, the treatments were not found to have any evident toxic effects (body weight, food/fluid consumption) on the TRAMP mice...c]phenanthridine alkaloids sanguinarine and chelerythrine: biological activities and dental care applications. Acta Univ Palacki Olomuc Fac Med 139:7
Glucose Sensing for Diabetes Monitoring: Recent Developments
Bruen, Danielle; Delaney, Colm; Florea, Larisa
2017-01-01
This review highlights recent advances towards non-invasive and continuous glucose monitoring devices, with a particular focus placed on monitoring glucose concentrations in alternative physiological fluids to blood. PMID:28805693
Sachat, Alexandros El; Meristoudi, Anastasia; Markos, Christos; Sakellariou, Andreas; Papadopoulos, Aggelos; Katsikas, Serafim; Riziotis, Christos
2017-03-11
Environmentally robust chemical sensors for monitoring industrial processes or infrastructures are lately becoming important devices in industry. Low complexity and wireless enabled characteristics can offer the required flexibility for sensor deployment in adaptable sensing networks for continuous monitoring and management of industrial assets. Here are presented the design, development and operation of a class of low cost photonic sensors for monitoring the ageing process and the operational characteristics of coolant fluids used in an industrial heavy machinery infrastructure. The chemical, physical and spectroscopic characteristics of specific industrial-grade coolant fluids were analyzed along their entire life cycle range, and proper parameters for their efficient monitoring were identified. Based on multimode polymer or silica optical fibers, wide range (3-11) pH sensors were developed by employing sol-gel derived pH sensitive coatings. The performances of the developed sensors were characterized and compared, towards their coolants' ageing monitoring capability, proving their efficiency in such a demanding application scenario and harsh industrial environment. The operating characteristics of this type of sensors allowed their integration in an autonomous wireless sensing node, thus enabling the future use of the demonstrated platform in wireless sensor networks for a variety of industrial and environmental monitoring applications.
El Sachat, Alexandros; Meristoudi, Anastasia; Markos, Christos; Sakellariou, Andreas; Papadopoulos, Aggelos; Katsikas, Serafim; Riziotis, Christos
2017-01-01
Environmentally robust chemical sensors for monitoring industrial processes or infrastructures are lately becoming important devices in industry. Low complexity and wireless enabled characteristics can offer the required flexibility for sensor deployment in adaptable sensing networks for continuous monitoring and management of industrial assets. Here are presented the design, development and operation of a class of low cost photonic sensors for monitoring the ageing process and the operational characteristics of coolant fluids used in an industrial heavy machinery infrastructure. The chemical, physical and spectroscopic characteristics of specific industrial-grade coolant fluids were analyzed along their entire life cycle range, and proper parameters for their efficient monitoring were identified. Based on multimode polymer or silica optical fibers, wide range (3–11) pH sensors were developed by employing sol-gel derived pH sensitive coatings. The performances of the developed sensors were characterized and compared, towards their coolants’ ageing monitoring capability, proving their efficiency in such a demanding application scenario and harsh industrial environment. The operating characteristics of this type of sensors allowed their integration in an autonomous wireless sensing node, thus enabling the future use of the demonstrated platform in wireless sensor networks for a variety of industrial and environmental monitoring applications. PMID:28287488
Computational Modeling of Seismic Wave Propagation Velocity-Saturation Effects in Porous Rocks
NASA Astrophysics Data System (ADS)
Deeks, J.; Lumley, D. E.
2011-12-01
Compressional and shear velocities of seismic waves propagating in porous rocks vary as a function of the fluid mixture and its distribution in pore space. Although it has been possible to place theoretical upper and lower bounds on the velocity variation with fluid saturation, predicting the actual velocity response of a given rock with fluid type and saturation remains an unsolved problem. In particular, we are interested in predicting the velocity-saturation response to various mixtures of fluids with pressure and temperature, as a function of the spatial distribution of the fluid mixture and the seismic wavelength. This effect is often termed "patchy saturation' in the rock physics community. The ability to accurately predict seismic velocities for various fluid mixtures and spatial distributions in the pore space of a rock is useful for fluid detection, hydrocarbon exploration and recovery, CO2 sequestration and monitoring of many subsurface fluid-flow processes. We create digital rock models with various fluid mixtures, saturations and spatial distributions. We use finite difference modeling to propagate elastic waves of varying frequency content through these digital rock and fluid models to simulate a given lab or field experiment. The resulting waveforms can be analyzed to determine seismic traveltimes, velocities, amplitudes, attenuation and other wave phenomena for variable rock models of fluid saturation and spatial fluid distribution, and variable wavefield spectral content. We show that we can reproduce most of the published effects of velocity-saturation variation, including validating the Voigt and Reuss theoretical bounds, as well as the Hill "patchy saturation" curve. We also reproduce what has been previously identified as Biot dispersion, but in fact in our models is often seen to be wave multi-pathing and broadband spectral effects. Furthermore, we find that in addition to the dominant seismic wavelength and average fluid patch size, the smoothness of the fluid patches are a critical factor in determining the velocity-saturation response; this is a result that we have not seen discussed in the literature. Most importantly, we can reproduce all of these effects using full elastic wavefield scattering, without the need to resort to more complicated squirt-flow or poroelastic models. This is important because the physical properties and parameters we need to model full elastic wave scattering, and predict a velocity-saturation curve, are often readily available for projects we undertake; this is not the case for poroelastic or squirt-flow models. We can predict this velocity saturation curve for a specific rock type, fluid mixture distribution and wavefield spectrum.
Is myelin basic protein a potential biomarker of brain cancer?
Zavialova, M G; Shevchenko, V E; Nikolaev, E N; Zgoda, V G
2017-08-01
Myelin basic protein is a potential biomarker for the central nervous system diseases in which the myelin sheath is destroyed. Using pseudo-selected reaction monitoring and the method of standard additions, we have measured the myelin basic protein level in the cerebrospinal fluid of patients with neurotrauma (n = 6), chronic neurodegenerative diseases (n = 2) and brain cancer (n = 5). Myelin basic protein was detected only in four out of five cerebrospinal fluid samples of patients with brain cancer. The cerebrospinal fluid myelin basic protein level ranged from 3.7 to 8.8 ng ml -1 . We suggest that monitoring of myelin basic protein in cerebrospinal fluid can serve as a diagnostic test for the brain cancer.
Method and apparatus for monitoring and measuring the surface tension of a fluid using fiber optics
Abraham, B.M.; Ketterson, J.B.; Bohanon, T.M.; Mikrut, J.M.
1994-04-12
A non-contact method and apparatus are described for measuring and monitoring the surface of a fluid using fiber optics and interferometric detection to permit measurement of mechanical characteristics of fluid surfaces. The apparatus employs an alternating electric field gradient for generating a capillary wave on the surface of the fluid. A fiber optic coupler and optical fiber directs a portion of a laser beam onto the surface of the fluid, another portion of the laser beam onto the photo sensor, and directs light reflected from the surface of the fluid onto the photo sensor. The output of the photo sensor is processed and coupled to a phase sensitive detector to permit measurement of phase shift between the drive signal creating the capillary wave and the detected signal. This phase shift information is then used to determine mechanical properties of the fluid surface such as surface tension, surface elasticity, and surface inhomogeneity. The resulting test structure is easily made compact, portable, and easy to align and use. 4 figures.
Apparatus for and Method of Monitoring Condensed Water in Steam Pipes at High Temperature
NASA Technical Reports Server (NTRS)
Lih, Shyh-Shiuh (Inventor); Bao, Xiaoqi (Inventor); Bar-Cohen, Yoseph (Inventor); Lee, Hyeong Jae (Inventor)
2016-01-01
A system and method for monitoring the properties of a fluid, such as water, in a steam pipe without mechanically penetrating the wall of the pipe. The system uses a piezoelectric transducer to launch an ultrasonic probe signal into the pipe. Reflected ultrasonic signals are captured in a transducer, which can be the same transducer that launched the probe signal. The reflected signals are subjected to data processing, which can include filtering, amplification, analog-to-digital conversion and autocorrelation analysis. A result is extracted which is indicative of a property of the fluid, such as a height of the condensed fluid, a cavitation of the condensed fluid, and a surface perturbation of the condensed fluid. The result can be recorded, displayed, and/or transmitted to another location. One embodiment of the system has been constructed and tested based on a general purpose programmable computer using instructions recorded in machine-readable non-volatile memory.
In-Service Monitoring of Steam Pipe Systems at High Temperatures
NASA Technical Reports Server (NTRS)
Sherrit, Stewart (Inventor); Scott, James Samson (Inventor); Bar-Cohen, Yoseph (Inventor); Badescu, Mircea (Inventor); Widholm, Scott E. (Inventor); Lih, Shyh-Shiuh (Inventor); Bao, Xiaoqi (Inventor); Blosiu, Julian O. (Inventor)
2014-01-01
A system and method for monitoring the properties of a fluid, such as water, in a steam pipe without mechanically penetrating the wall of the pipe. The system uses a piezoelectric transducer to launch an ultrasonic probe signal into the pipe. Reflected ultrasonic signals are captured in a transducer, which can be the same transducer that launched the probe signal. The reflected signals are subjected to data processing, which can include filtering, amplification, analog-to-digital conversion and autocorrelation analysis. A result is extracted which is indicative of a property of the fluid, such as a height of the condensed fluid, a cavitation of the condensed fluid, and a surface perturbation of the condensed fluid. The result can be recorded, displayed, and/or transmitted to another location. One embodiment of the system has been constructed and tested based on a general purpose programmable computer using instructions recorded in machine-readable non-volatile memory.
NASA Astrophysics Data System (ADS)
Lipani, Luca; Dupont, Bertrand G. R.; Doungmene, Floriant; Marken, Frank; Tyrrell, Rex M.; Guy, Richard H.; Ilie, Adelina
2018-06-01
Currently, there is no available needle-free approach for diabetics to monitor glucose levels in the interstitial fluid. Here, we report a path-selective, non-invasive, transdermal glucose monitoring system based on a miniaturized pixel array platform (realized either by graphene-based thin-film technology, or screen-printing). The system samples glucose from the interstitial fluid via electroosmotic extraction through individual, privileged, follicular pathways in the skin, accessible via the pixels of the array. A proof of principle using mammalian skin ex vivo is demonstrated for specific and `quantized' glucose extraction/detection via follicular pathways, and across the hypo- to hyper-glycaemic range in humans. Furthermore, the quantification of follicular and non-follicular glucose extraction fluxes is clearly shown. In vivo continuous monitoring of interstitial fluid-borne glucose with the pixel array was able to track blood sugar in healthy human subjects. This approach paves the way to clinically relevant glucose detection in diabetics without the need for invasive, finger-stick blood sampling.
Módenes, Aparecido Nivaldo; Sanderson, Karina; Trigueros, Daniela Estelita Goes; Schuelter, Adilson Ricken; Espinoza-Quiñones, Fernando Rodolfo; Neves, Camila Vargas; Zanão Junior, Luiz Antônio; Kroumov, Alexander Dimitrov
2018-05-01
Leakage of transformer dielectric fluids is a concern because it may pose a risk of environmental contamination. In this study, the deleterious effects of vegetable and mineral dielectric fluids in water bodies were investigated using biodegradability and acute toxicity tests with Danio rerio and Artemia salina. Regarding biodegradability, all four tested vegetable oils (soy, canola, sunflower and crambe) were considered as easily biodegradable, presenting degradation rates significantly higher than the Lubrax-type mineral fluid. Acute toxicity tests were performed in two separate experiments without solution renewal. In the first experiment, the organisms were exposed in direct contact to different concentrations of vegetable (soy) and mineral (Lubrax) oils. Total soy-type vegetable oil has a higher toxic effect than Lubrax-type mineral oil. In the second experiment, the organisms were exposed to increasing percentages of the water-soluble fraction (WSF) of both types of tested oils. The LC 50 values for the water-soluble fraction of the Lubrax-type mineral oil were about 5 and 8% for the Danio rerio and Artemia salina bioindicators, respectively, whereas the vegetable oil did not present toxic effect, regardless of its WSF. These results have shown that a strict selection of dielectric fluids and monitoring the leakage from power transformers is a serious duty of environmental protection agencies. Copyright © 2018 Elsevier Ltd. All rights reserved.
Engineering considerations for corrosion monitoring of gas gathering pipeline systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Braga, T.G.; Asperger, R.G.
1987-01-01
Proper corrosion monitoring of gas gathering pipelines requires a system review to determine the appropriate monitor locations and types of monitoring techniques. This paper develops and discusses a classification of conditions such as flow regime and gas composition. Also discussed are junction categories which, for corrosion monitoring, need to be considered from two points of view. The first is related to fluid flow in the line and the second is related corrosion inhibitor movement along the pipeline. The appropriate application of the various monitoring techniques such as coupons, hydrogen detectors, electrical resistance probe and linear polarization probes are discussed inmore » relation to flow regime and gas composition. Problems caused by semi-conduction from iron sulfide are considered. Advantages and disadvantages of fluid gathering methods such as pots and flow-through drips are discussed in relation to their reliability as on-line monitoring locations.« less
Perioperative fluid management: From physiology to improving clinical outcomes.
Bennett, Victoria A; Cecconi, Maurizio
2017-08-01
Perioperative fluid management is a key component in the care of the surgical patient. It is an area that has seen significant changes and developments, however there remains a wide disparity in practice between clinicians. Historically, patients received large volumes of intravenous fluids perioperatively. The concept of goal directed therapy was then introduced, with the early studies showing significant improvements in morbidity and mortality. The current focus is on fluid therapy guided by an individual patient's physiology. A fluid challenge is commonly performed as part of an assessment of a patient's fluid responsiveness. There remains wide variation in how clinicians perform a fluid challenge and this review explores the evidence for how to administer an effective challenge that is both reliable and reproducible. The methods for monitoring cardiac output have evolved from the pulmonary artery catheter to a range of less invasive techniques. The different options that are available for perioperative use are considered. Fluid status can also be assessed by examining the microcirculation and the importance of recognising the possibility of a lack of coherence between the macro and microcirculation is discussed. Fluid therapy needs to be targeted to specific end points and individualised. Not all patients who respond to a fluid challenge will necessarily require additional fluid administration and care should be aimed at identifying those who do. This review aims to explain the underlying physiology and describe the evidence base and the changes that have been seen in the approach to perioperative fluid therapy.
NASA Astrophysics Data System (ADS)
Santoyo, E.; Verma, S. P.; Nieva, D.; Portugal, E.
1991-07-01
Studies related to hydrological structure of the Los Azufres geothermal field and its effects on the exploitation of the field for generation of electrical energy have included a program of sampling and chemical analysis of fluids discharged by a number of deep wells in continuous production. Chemical analysis of the gaseous phase includes monitoring of CO 2, H 2S, NH 3, H 2, He, N 2, CH 4 and 222Rn. Five wells in Los Azufres field were periodically sampled during 1983-1988. The monitoring program has shown considerable variability in the gas concentrations of fluids. Before mid-1985, the 'base-line' concentrations of the gases showed standard deviations between 8 and 28%. During the later period, the average concentrations of different gases ranged from 37% to much higher values above the 'base-line'. The largest variations are observed in He, CO 2 and 222Rn. This variability is interpreted in terms of (1) addition of 'excess steam', (2) a possible relationship with earthquake events that occurred in México during September 19-21, 1985, and early May to early June of 1987 and, (3) more recent variations (after mid-1987), increased exploitation of the field.
21 CFR 868.2450 - Lung water monitor.
Code of Federal Regulations, 2014 CFR
2014-04-01
... DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2450 Lung water monitor. (a) Identification. A lung water monitor is a device used to monitor the trend of fluid volume changes in a patient's lung by... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Lung water monitor. 868.2450 Section 868.2450 Food...
21 CFR 868.2450 - Lung water monitor.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Lung water monitor. 868.2450 Section 868.2450 Food... DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2450 Lung water monitor. (a) Identification. A lung water monitor is a device used to monitor the trend of fluid volume changes in a patient's lung by...
21 CFR 868.2450 - Lung water monitor.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Lung water monitor. 868.2450 Section 868.2450 Food... DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2450 Lung water monitor. (a) Identification. A lung water monitor is a device used to monitor the trend of fluid volume changes in a patient's lung by...
21 CFR 868.2450 - Lung water monitor.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Lung water monitor. 868.2450 Section 868.2450 Food... DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2450 Lung water monitor. (a) Identification. A lung water monitor is a device used to monitor the trend of fluid volume changes in a patient's lung by...
21 CFR 868.2450 - Lung water monitor.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Lung water monitor. 868.2450 Section 868.2450 Food... DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2450 Lung water monitor. (a) Identification. A lung water monitor is a device used to monitor the trend of fluid volume changes in a patient's lung by...
Monitoring and blunting styles in fluid restriction consultation.
Lindberg, Magnus
2012-04-01
Excessive fluid overload is common in hemodialysis patients. Understanding fluid intake behavior in relation to used cognitive coping style would serve the fluid restriction consultation. The aim of this study was to explore whether hemodialysis patients' fluid intake behavior differs as a function of used coping style. Secondary analysis of data from 51 hemodialysis patients regarding cognitive coping style (assessed by the Threatening Medical Situations Inventory) and fluid intake behavior were used. The participants' mean age was 62.9 years (range 27-84), they had received dialysis treatment for 3.9 years on average (range 0-22), 63% were male and they had gained 3.6% (±1.3) of their dry body weight during the interdialytic period. There was a significant difference in fluid intake behavior between coping groups (F = 3.899, d.f. 2, P = 0.027). The difference (P = 0.028) was isolated between patients with cognitive blunting style and patients with neutral coping style. Identification of hemodialysis patients using cognitive avoidance strategies can be advantageous in renal care. Fluid advice provided may have to be adjusted to the used coping style, especially for patients with a blunting coping style. However, the findings need to be confirmed, and the effect of individualized counseling needs to be evaluated in forthcoming studies.
Thermal Decoherence of a Nonequilibrium Polariton Fluid
NASA Astrophysics Data System (ADS)
Klembt, Sebastian; Stepanov, Petr; Klein, Thorsten; Minguzzi, Anna; Richard, Maxime
2018-01-01
Exciton polaritons constitute a unique realization of a quantum fluid interacting with its environment. Using selenide-based microcavities, we exploit this feature to warm up a polariton condensate in a controlled way and monitor its spatial coherence. We determine directly the amount of heat picked up by the condensate by measuring the phonon-polariton scattering rate and comparing it with the loss rate. We find that, upon increasing the heating rate, the spatial coherence length decreases markedly, while localized phase structures vanish, in good agreement with a stochastic mean-field theory. From the thermodynamical point of view, this regime is unique, as it involves a nonequilibrium quantum fluid with no well-defined temperature but which is nevertheless able to pick up heat with dramatic effects on the order parameter.
McCullough, J; Keller, H
2018-01-01
Hospital malnutrition is an under-recognized issue that leads to a variety of adverse outcomes, especially for older adults. Food/fluid intake (FFI) monitoring in hospital can be used to identify those who are improving and those who need further treatment. Current monitoring practices such as calorie counts are impractical for all patients and a patient-completed tool, if valid, could support routine FFI monitoring. The aim of this research was to determine whether the patient-completed My Meal Intake Tool (M-MIT) can accurately represent FFI at a single meal. Cross-sectional, multi-site. Four acute care hospitals in Canada. 120 patients (65+ yrs, adequate cognition). Participants completed M-MIT for a single meal. Food and fluid waste was visually estimated by a research dietitian at each hospital. Sensitivity (Se), specificity (Sp) and overall agreement were calculated for both food and fluid intake by comparing M-MIT and dietitian estimations to determine criterion validity of M-MIT. Patient and research dietitian comments were used to make revisions to the M-MIT. Using a cut-point of ≤50% intake, Se was 76.2% and 61.9% and Sp was 74.0% and 80.5% for solid and fluids respectively (p<0.001). M-MIT identified a greater proportion of participants (37.2%) as having low FFI (≤50%) than dietitians (25.0%), as well as a greater proportion identified with low fluid intake (28.3% vs. 24.6%). Modest revisions were made to improve the tool. This study has demonstrated initial validity of M-MIT for use in older patients with adequate cognition. Use of M-MIT could promote FFI monitoring as a routine practice to make clinical decisions about care.
Van Biesen, Wim; Williams, John D.; Covic, Adrian C.; Fan, Stanley; Claes, Kathleen; Lichodziejewska-Niemierko, Monika; Verger, Christian; Steiger, Jurg; Schoder, Volker; Wabel, Peter; Gauly, Adelheid; Himmele, Rainer
2011-01-01
Background Euvolemia is an important adequacy parameter in peritoneal dialysis (PD) patients. However, accurate tools to evaluate volume status in clinical practice and data on volume status in PD patients as compared to healthy population, and the associated factors, have not been available so far. Methods We used a bio-impedance spectroscopy device, the Body Composition Monitor (BCM) to assess volume status in a cross-sectional cohort of prevalent PD patients in different European countries. The results were compared to an age and gender matched healthy population. Results Only 40% out of 639 patients from 28 centres in 6 countries were normovolemic. Severe fluid overload was present in 25.2%. There was a wide scatter in the relation between blood pressure and volume status. In a multivariate analysis in the subgroup of patients from countries with unrestricted availability of all PD modalities and fluid types, older age, male gender, lower serum albumin, lower BMI, diabetes, higher systolic blood pressure, and use of at least one exchange per day with the highest hypertonic glucose were associated with higher relative tissue hydration. Neither urinary output nor ultrafiltration, PD fluid type or PD modality were retained in the model (total R2 of the model = 0.57). Conclusions The EuroBCM study demonstrates some interesting issues regarding volume status in PD. As in HD patients, hypervolemia is a frequent condition in PD patients and blood pressure can be a misleading clinical tool to evaluate volume status. To monitor fluid balance, not only fluid output but also dietary input should be considered. Close monitoring of volume status, a correct dialysis prescription adapted to the needs of the patient and dietary measures seem to be warranted to avoid hypervolemia. PMID:21390320
The fracture criticality of crustal rocks
NASA Astrophysics Data System (ADS)
Crampin, Stuart
1994-08-01
The shear-wave splitting observed along almost all shear-wave ray paths in the Earth's crust is interpreted as the effects of stress-aligned fluid-filled cracks, microcracks, and preferentially oriented pore space. Once away from the free surface, where open joints and fractures may lead to strong anisotropy of 10 per cent or greater, intact ostensibly unfractured crustal rock exhibits a limited range of shear-wave splitting from about 1.5 to 4.5 per cent differential shear-wave velocity anisotropy. Interpreting this velocity anisotropy as normalized crack densities, a factor of less than two in crack radius covers the range from the minimum 1.5 per cent anisotropy observed in intact rock to the 10 per cent observed in heavily cracked almost disaggregated near-surface rocks. This narrow range of crack dimensions and the pronounced effect on rock cohesion suggests that there is a state of fracture criticality at some level of anisotropy between 4.5 and 10 per cent marking the boundary between essentially intact, and heavily fractured rock. When the level of fracture criticality is exceeded, cracking is so severe that there is a breakdown in shear strength, the likelihood of progressive fracturing and the dispersal of pore fluids through enhanced permeability. The range of normalized crack dimensions below fracture criticality is so small in intact rock, that any modification to the crack geometry by even minor changes of conditions or minor deformation (particularly in the presence of high pore-fluid pressures) may change rock from being essentially intact (below fracture criticality) to heavily fractured (above fracture criticality). This recognition of the essential compliance of most crustal rocks, and its effect on shear-wave splitting, has implications for monitoring changes in any conditions affecting the rock mass. These include monitoring changes in reservoir evolution during hydrocarbon production and enhanced oil recovery, and in monitoring changes before and after earthquakes, amongst others.
Chantada-Vázquez, María Pilar; de-Becerra-Sánchez, Carolina; Fernández-Del-Río, Alba; Sánchez-González, Juan; Bermejo, Ana María; Bermejo-Barrera, Pilar; Moreda-Piñeiro, Antonio
2018-05-01
A molecularly imprinted polymer - Mn-doped ZnS quantum dot-based fluorescence probe for cocaine abuse screening has been prepared and applied to complex samples such as serum and oral fluid. The fluorescent sensing material was prepared by anchoring a selective MIP for COC on the surface of polyethylene glycol (PEG) modified Mn-doped ZnS quantum dots (QDs). Simple and low cost methods have thus been optimized for assessing cocaine abuse in serum and oral fluid by monitoring fluorescence quenching when cocaine (COC) is present (optimized operating conditions with 1.5mL of 200mgL -1 MIP-coated QDs solution, pH 5.5, and 15min before fluorescence scanning). The matrix effect was found to be important when analyzing oral fluid and serum, and several strategies based on centrifugation for oral fluid and solid phase extraction (SPE) for serum were explored. Two analytical methods were developed for oral fluid. The first one (direct method) requires a centrifugation step (6°C, 4000rpm, 20min) to avoid the matrix effect, and allows for cocaine determination by using an aqueous calibration (1:20 dilution). The second method was developed for oral fluid sampled by Salivette devices, and also requires a further centrifugation (6°C, 4000rpm, 20min) of the recovered oral fluid. This method, however, requires the standard addition technique (1:20 dilution) because of the existence of the matrix effect. Regarding serum samples, a direct method (serum dilution) was not possible, and an SPE procedure was needed to avoid the matrix effect (use of aqueous calibration). The limits of detection and quantification when using the Salivette method were 0.035mgL -1 and 0.117mgL -1, respectively; whereas, 0.015mgL -1 (LOD) and 0.050mgL -1 (LOQ) were obtained for serum. Copyright © 2018 Elsevier B.V. All rights reserved.
Monitoring an EGS injection at Newberry Volcano using Magnetotelluric dimensionality analysis
NASA Astrophysics Data System (ADS)
Bowles-martinez, E.; Schultz, A.; Rose, K.; Urquhart, S.
2016-12-01
The sensitivity of magnetotelluric (MT) data to the presence of electrically conductive subsurface features makes it applicable for determining the extent of injected fluids in enhanced geothermal systems (EGS). We use MT to monitor fluid injection during tests of a proposed EGS site at Newberry Volcano in Central Oregon, USA. Newberry is a large shield volcano located where fault systems of the northern Basin and Range meet the Cascade Arc and the high lava plains. Its strong potential for geothermal energy has made it a target for energy exploration for over 40 years. MT measurements were made before, during, and after an EGS stimulation in 2014 in an effort to detect subsurface pathways taken by fluids that are attributable to stimulation. We begin by creating a baseline model from inverting over 200 wideband MT stations located in the western half of the volcano. This model is constrained by well logs, as well as by high resolution gravity and seismic velocity modeling. Our model shows conductive regions associated with the caldera's ring fault, likely showing where hydrothermal fluids or their mineral alteration products are present. However, as this is an EGS study, we are interested in detecting fluid intrusion into hot, dry rock. Therefore, our primary target is a resistive zone on the western flank of Newberry volcano that is interpreted as a series of hot intrusive sequences. Well bottom temperatures in this area have been measured in excess of 300 °C. The stimulation's effect on resistivity is subtle, in part because the injected fluid is fresh groundwater, the injected volume is modest, and the target depth is 2,000-3,000 m below ground level. We found that it is advantageous to look at the impedance tensor data directly to detect injected fluids. Because fluids and their associated change in resistivity are expected to be concentrated around the injection well, the injection will exhibit a highly three-dimensional resistivity structure. Therefore, we examine the impedance tensor for changes in dimensionality to mark the arrival of injected fluids. We then present a method of inverting MT data for changes in impedance rather than for resistivity.
Monodisperse granular flows in viscous dispersions in a centrifugal acceleration field
NASA Astrophysics Data System (ADS)
Cabrera, Miguel Angel; Wu, Wei
2016-04-01
Granular flows are encountered in geophysical flows and innumerable industrial applications with particulate materials. When mixed with a fluid, a complex network of interactions between the particle- and fluid-phase develops, resulting in a compound material with a yet unclear physical behaviour. In the study of granular suspensions mixed with a viscous dispersion, the scaling of the stress-strain characteristics of the fluid phase needs to account for the level of inertia developed in experiments. However, the required model dimensions and amount of material becomes a main limitation for their study. In recent years, centrifuge modelling has been presented as an alternative for the study of particle-fluid flows in a reduced scaled model in an augmented acceleration field. By formulating simple scaling principles proportional to the equivalent acceleration Ng in the model, the resultant flows share many similarities with field events. In this work we study the scaling principles of the fluid phase and its effects on the flow of granular suspensions. We focus on the dense flow of a monodisperse granular suspension mixed with a viscous fluid phase, flowing down an inclined plane and being driven by a centrifugal acceleration field. The scaled model allows the continuous monitoring of the flow heights, velocity fields, basal pressure and mass flow rates at different Ng levels. The experiments successfully identify the effects of scaling the plastic viscosity of the fluid phase, its relation with the deposition of particles over the inclined plane, and allows formulating a discussion on the suitability of simulating particle-fluid flows in a centrifugal acceleration field.
Flow accelerated organic coating degradation
NASA Astrophysics Data System (ADS)
Zhou, Qixin
Applying organic coatings is a common and the most cost effective way to protect metallic objects and structures from corrosion. Water entry into coating-metal interface is usually the main cause for the deterioration of organic coatings, which leads to coating delamination and underfilm corrosion. Recently, flowing fluids over sample surface have received attention due to their capability to accelerate material degradation. A plethora of works has focused on the flow induced metal corrosion, while few studies have investigated the flow accelerated organic coating degradation. Flowing fluids above coating surface affect corrosion by enhancing the water transport and abrading the surface due to fluid shear. Hence, it is of great importance to understand the influence of flowing fluids on the degradation of corrosion protective organic coatings. In this study, a pigmented marine coating and several clear coatings were exposed to the laminar flow and stationary immersion. The laminar flow was pressure driven and confined in a flow channel. A 3.5 wt% sodium chloride solution and pure water was employed as the working fluid with a variety of flow rates. The corrosion protective properties of organic coatings were monitored inline by Electrochemical Impedance Spectroscopy (EIS) measurement. Equivalent circuit models were employed to interpret the EIS spectra. The time evolution of coating resistance and capacitance obtained from the model was studied to demonstrate the coating degradation. Thickness, gloss, and other topography characterizations were conducted to facilitate the assessment of the corrosion. The working fluids were characterized by Fourier Transform Infrared Spectrometer (FTIR) and conductivity measurement. The influence of flow rate, fluid shear, fluid composition, and other effects in the coating degradation were investigated. We conclude that flowing fluid on the coating surface accelerates the transport of water, oxygen, and ions into the coating, as well as promotes the migration of coating materials from the coating into the working fluid, where coatings experience more severe deterioration in their barrier property under flowing conditions. Pure water has shown to be a much more aggressive working fluid than electrolyte solutions. The flowing fluid over the coating surface could be used as an effective acceleration method.
Miniaturized Bio-and Chemical-Sensors for Point-of-Care Monitoring of Chronic Kidney Diseases
Tricoli, Antonio
2018-01-01
This review reports the latest achievements in point-of-care (POC) sensor technologies for the monitoring of ammonia, creatinine and urea in patients suffering of chronic kidney diseases (CKDs). Abnormal levels of these nitrogen biomarkers are found in the physiological fluids, such as blood, urine and sweat, of CKD patients. Delocalized at-home monitoring of CKD biomarkers via integration of miniaturized, portable, and low cost chemical- and bio-sensors in POC devices, is an emerging approach to improve patients’ health monitoring and life quality. The successful monitoring of CKD biomarkers, performed on the different body fluids by means of sensors having strict requirements in term of size, cost, large-scale production capacity, response time and simple operation procedures for use in POC devices, is reported and discussed. PMID:29565315
Miniaturized Bio-and Chemical-Sensors for Point-of-Care Monitoring of Chronic Kidney Diseases.
Tricoli, Antonio; Neri, Giovanni
2018-03-22
This review reports the latest achievements in point-of-care (POC) sensor technologies for the monitoring of ammonia, creatinine and urea in patients suffering of chronic kidney diseases (CKDs). Abnormal levels of these nitrogen biomarkers are found in the physiological fluids, such as blood, urine and sweat, of CKD patients. Delocalized at-home monitoring of CKD biomarkers via integration of miniaturized, portable, and low cost chemical- and bio-sensors in POC devices, is an emerging approach to improve patients' health monitoring and life quality. The successful monitoring of CKD biomarkers, performed on the different body fluids by means of sensors having strict requirements in term of size, cost, large-scale production capacity, response time and simple operation procedures for use in POC devices, is reported and discussed.
Ultrasonic fluid densitometer for process control
Greenwood, Margaret S.
2000-01-01
The present invention is an ultrasonic fluid densitometer that uses at least one pair of transducers for transmitting and receiving ultrasonic signals internally reflected within a material wedge. A temperature sensor is provided to monitor the temperature of the wedge material. Density of a fluid is determined by immersing the wedge into the fluid and measuring reflection of ultrasound at the wedge-fluid interface and comparing a transducer voltage and wedge material temperature to a tabulation as a function of density.
NASA Astrophysics Data System (ADS)
David, Christian; Sarout, Joël.; Dautriat, Jérémie; Pimienta, Lucas; Michée, Marie; Desrues, Mathilde; Barnes, Christophe
2017-07-01
Fluid substitution processes have been investigated in the laboratory on 14 carbonate and siliciclastic reservoir rock analogues through spontaneous imbibition experiments on vertical cylindrical specimens with simultaneous ultrasonic monitoring and imaging. The motivation of our study was to identify the seismic attributes of fluid substitution in reservoir rocks and to link them to physical processes. It is shown that (i) the P wave velocity either decreases or increases when the capillary front reaches the Fresnel clearance zone, (ii) the P wave amplitude is systematically impacted earlier than the velocity is, (iii) this precursory amplitude decrease occurs when the imbibition front is located outside of the Fresnel zone, and (iv) the relative variation of the P wave amplitude is always much larger than that of the P wave velocity. These results suggest that moisture diffuses into the pore space ahead of the water front. This postulate is further supported by a quantitative analysis of the time evolution of the observed P wave amplitudes. In a sense, P wave amplitude acts as a precursor of the arrival of the capillary front. This phenomenon is used to estimate the effective diffusivity of moisture in the tested rocks. The effective moisture diffusivity estimated from the ultrasonic data is strongly correlated with permeability: a power law with exponent 0.96 predicts permeability from ultrasonic monitoring within a factor 3 without noticeable bias. When the effective diffusivity is high, moisture diffusion affects ultrasonic P wave attributes even before the imbibition starts and impacts the P wave reflectivity as evidenced by the variations recorded in the waveform coda.
Towards a smart non-invasive fluid loss measurement system.
Suryadevara, N K; Mukhopadhyay, S C; Barrack, L
2015-04-01
In this article, a smart wireless sensing non-invasive system for estimating the amount of fluid loss, a person experiences while physical activity is presented. The system measures three external body parameters, Heart Rate, Galvanic Skin Response (GSR, or skin conductance), and Skin Temperature. These three parameters are entered into an empirically derived formula along with the user's body mass index, and estimation for the amount of fluid lost is determined. The core benefit of the developed system is the affluence usage in combining with smart home monitoring systems to care elderly people in ambient assisted living environments as well in automobiles to monitor the body parameters of a motorist.
Microminiature Monitor for Vital Electrolyte and Metabolite Levels of Astronauts
NASA Technical Reports Server (NTRS)
Tohda, Koji; Gratzl, Miklos
2004-01-01
Ions, such as proton (pH) and potassium, play a crucial role in body fluids to maintain proper basic functioning of cells and tissues. Metabolites, such as glucose, control the energy available to the entire human body in normal as well as stress situations, and before, during, and after meals. These molecules diffuse easily between blood in the capillaries and the interstitial fluid residing between cells and tissues. We have developed and approach to monitoring of critical ions (called electrolytes) and glucose in the interstitial fluid under the human skin. Proton and potassium levels sensed using optode technology that translates the respective ionic concentrations into variable colors of corresponding ionophore/dye/polymeric liquid membranes. Glucose is monitored indirectly, by coupling through immobilized glucose oxidase with local pH that is then detected using a similar color scheme. The monitor consists of a tiny plastic bar, 100-200 microns wide and 1-2 mm long, placed just under the skin, with color changing spots for each analyte as well as blanks. The colors are read and translated into concentration values by a CCD camera. Direct optical coupling between the in vivo sensing bar and the ex vivo detector device requires no power, and thus eliminates the need for wires or optical fibers crossing the skin. The microminiature bar penetrates the skin easily and painlessly, so that astronauts could insert it themselves. The approach is fully compatible with telemetry in space, and thus, in vivo clinical data will be available real time in the Earth based command center once the device is fully developed. The information provided can be used for collecting hitherto unavailable vital data on clinical effects of space travel. Managing clinical emergencies in space with the sensor already in place should also become much more efficient than without a continuous monitor, as is currently the case. Civilian applications may include better glucose control of patients with moderate to severe diabetes: a growing health problem in the US and World-wide.
Sensors for Environmental Control
NASA Technical Reports Server (NTRS)
1996-01-01
Under a Kennedy Space Center Small Business Innovation Research contract, GEO-CENTERS, Inc. developed a sensing element or 'optrode,' which NASA needed for space life support research to measure a hydroponic culture's pH factor. The company then commercialized the technology in the PC Based pH Monitoring System. The system employs the optrode to enable long term continuous monitoring of the pH level of fluids in standing and flowing conditions, an optoelectronic board with light sensors and detectors that fits into a desktop computer, and a fiber optic cable that connects the two. The system is effective in monitoring the pH output of industries to maintain ranges acceptable to the Environmental Protection Agency.
NASA Astrophysics Data System (ADS)
Hajash, Andrew; Carpenter, Thomas D.; Dewers, Thomas A.
1998-09-01
Aqueous fluids are important in the diagenesis and deformation of crustal rocks. Both chemical and physical interactions are involved and often they are strongly coupled. For example, pore waters not only dissolve, transport, and precipitate chemical species, but they also substantially affect the mechanical behavior of the rocks that contain them. Stresses magnified at grain contacts by differences in pore-fluid pressure ( Pp) and confining pressure ( Pc) can, in turn, influence the rate and extent of chemical exchange. To begin investigation of these coupled systems, compaction experiments were conducted using albite sand (250-500 μm) and distilled water (pH 5.8), 0.07 M acetate (pH 4.7), and 0.07 M acetate + 0.005 M citrate (pH 4.4) solutions in a hydrothermal flow-through system at conditions that simulate diagenesis. Pore-fluid chemistry and pore-volume loss were monitored to quantify the effects of organic acids on time-dependent compaction rates. The effects of stress and fluid chemistry on the dissolution kinetics were also examined. Albite dissolution rates, monitored by steady-state fluid chemistry, increased when an effective pressure ( Pe= Pc- Pp) was applied, probably due to increases in total surface area caused by grain breakage at contacts. These effects were transient in distilled water, however, Si and Al concentrations remained elevated in the acetate pore fluid. The average Si-based release rates indicate ≈35% increase in reactive surface area by application of Pe=34.5 MPa. At 100°C with Pe=34.5 MPa, steady-state Si concentrations were ≈2.3 times higher in 0.07 M acetate and 5.8 times higher in 0.07 M acetate + 0.005 M citrate than in distilled water. Al increased by even larger factors (3× in the acetate buffer and 10× in the citrate solution). These changes in fluid chemistry are attributed to both pH and ligand-enhanced reactions. Albite dissolution appears to be controlled by surface complexation reactions at Al sites. Rapid dissolution of albite in the organic acid solutions is probably due to the ability of organic acid ligands to selectively complex with aluminum. Time-dependent compaction was observed at 100 and 160°C with Pe=34.5 MPa. Strain rates increased with temperature from ≈10 -9 s -l at 100°C to ≈10 -8 s -l at 160°C and decreased with strain in all pore fluids, especially at 100°C. Compaction rates in distilled water and in the acetate solution had similar magnitudes and strain dependencies; however, small amounts of citrate species apparently enhance compaction compared to the other fluids at similar strains. Textural data indicate that time-dependent compaction of the albite sand occurred primarily by brittle mechanisms at these temperatures. However, the deformation is clearly thermally activated and may be chemically assisted by the aqueous pore fluid.
Selective placement disposal of drilling fluids in west Texas
DOE Office of Scientific and Technical Information (OSTI.GOV)
McFarland, M.L.
1988-01-01
Burial of spent drilling fluids used in petroleum and natural gas exploration was evaluated as an alternative disposal technique for reducing surface soil contamination in western Texas. Simulated reserve pits were constructed to provide burial depths of 30, 90, and 150 cm below the surface, with orderly replacement of stockpiled subsoil and topsoil. Movement of soluble salts and heavy metals from drilling fluids into the overlying soil was monitored over a 20-month period. The effects of depth of drilling fluid burial on establishment, yields, and chemical composition of transplanted fourwing saltbush (Atriplex canescens (Pursh) Nutt.) and buffalograss (Buchloe dactyloides (Nutt.)more » Engelm.) were determined for two growing seasons. Sodium, Ca{sup +2}, and Cl{sup {minus}} were the dominant mobile ions, while migration of Mg{sup +2}, K{sup +}, and SO{sub 4}{sup {minus}2} was observed to a lesser degree. Exchangeable sodium percentages in the 15-cm zone immediately above drilling fluid ranged from 1.9 to 19.0 after 20 months. Total concentrations of Ba, Cr, Cu, Ni, and Zn were greater in drilling fluids than in native soil, but there was no evidence of migration of these metals into overlying soil.« less
Caffeine Inhibits Fluid Secretion by Interlobular Ducts From Guinea Pig Pancreas.
Mochimaru, Yuka; Yamamoto, Akiko; Nakakuki, Miyuki; Yamaguchi, Makoto; Taniguchi, Ituka; Ishiguro, Hiroshi
2017-04-01
Caffeine is contained in coffee, tea, and numerous beverages and foods. We examined the direct effects of caffeine on the physiological function of pancreatic duct cells by using interlobular duct segments isolated from guinea pig pancreas. The rate of fluid secretion was continuously measured by monitoring the luminal volume of isolated duct segments. Changes in intracellular Ca concentration ([Ca]i) were estimated by microfluorometry in ducts loaded with Fura-2. Both secretin-stimulated and acetylcholine (ACh)-stimulated fluid secretions were substantially and reversibly inhibited by relatively low concentrations of caffeine as low as 0.03 mM relevant to blood levels after ingestion of caffeine-containing beverages. Caffeine inhibited ACh-induced elevation of [Ca]i and secretin-induced fluctuation of [Ca]i. Caffeine abolished thapsigargin-induced intracellular Ca release but did not affect the entry of extracellular Ca. Caffeine (0.05 mM) abolished ethanol (1 mM)-induced fluid hypersecretion in secretin-stimulated pancreatic duct. Low concentrations of caffeine directly inhibit pancreatic ductal fluid secretion stimulated by secretin or ACh and also ethanol-induced fluid hypersecretion. The inhibition by caffeine seems to be mediated by the blockade of intracellular Ca mobilization. Daily intake of caffeine may reduce the volume of pancreatic juice secretion.
PVDF Sensor Stimulated by Infrared Radiation for Temperature Monitoring in Microfluidic Devices.
Pullano, Salvatore A; Mahbub, Ifana; Islam, Syed K; Fiorillo, Antonino S
2017-04-13
This paper presents a ferroelectric polymer-based temperature sensor designed for microfluidic devices. The integration of the sensor into a system-on-a-chip platform facilitates quick monitoring of localized temperature of a biological fluid, avoiding errors in the evaluation of thermal evolution of the fluid during analysis. The contact temperature sensor is fabricated by combining a thin pyroelectric film together with an infrared source, which stimulates the active element located on the top of the microfluidic channel. An experimental setup was assembled to validate the analytical model and to characterize the response rate of the device. The evaluation procedure and the operating range of the temperature also make this device suitable for applications where the localized temperature monitoring of biological samples is necessary. Additionally, ease of integration with standard microfluidic devices makes the proposed sensor an attractive option for in situ analysis of biological fluids.
System for monitoring physical characteristics of fluids
NASA Technical Reports Server (NTRS)
Trinh, E. H.; Wang, T. G. (Inventor)
1983-01-01
An apparatus and method are described for measuring physical characteristics of fluid, by placing a drop of the fluid in a batch of a second fluid and passing acoustic waves through the bath. The applied frequency of the acoustic waves is varied, to determine the precise value of a frequency at which the drop undergoes resonant oscillations. The resonant frequency indicates the interfacial tension of the drop in the bath, and the interfacial tension can indicate physical properties of the fluid in the drop.
Shah, Hemendra N; Kausik, Vikram; Hegde, Sunil; Shah, Jignesh N; Bansal, Manish B
2006-02-01
In a prospective manner we studied various factors affecting fluid absorption during HoLEP. We also simultaneously evaluated changes in serum electrolytes and hemoglobin decrease during HoLEP. This prospective study comprised of 53 patients who underwent HoLEP at our institute. Irrigation fluid was normal saline tagged with ethanol (1% w/v). Intraoperatively a standard breath analyzer was used to monitor expired breath ethanol levels during the procedure at 10-minute intervals. Patients who absorbed irrigating fluid as indicated by positive intraoperative breath tests were considered absorbers. Serum electrolyte and hemoglobin estimations were done before and after surgery. Total irrigation time, amount of irrigation fluid used, weight of resected tissue and presence of capsular perforation were recorded. Statistical analysis was performed to observe the effects of various factors on the amount of intraoperative fluid absorption. Of 53 patients studied 14 (26.41%) demonstrated fluid absorption in the range of 213 to 930 ml (mean 459). Preoperative prostate weight, total irrigation time, amount of irrigation fluid used and resected tissue weight were all significantly greater in absorbers. Similarly, absorbers had a statistically significant decrease in hemoglobin level postoperatively. There was no statistically significant change in serum electrolytes between absorbers and nonabsorbers. Preoperative weight of prostate, total irrigation time, amount of irrigation fluid used and weight of resected tissue all directly influence the amount of fluid absorption during HoLEP. There is no significant change in serum electrolytes and no risk of the transurethral resection syndrome.
Construction and test of an artificial uterus for ex situ development of shark embryos.
Nick, Otway; Megan, Ellis
2012-01-01
An artificial uterus (AU) was constructed from clear and opaque acrylic and life-support and monitoring systems were attached. The dwarf ornate wobbegong shark (Orectolobus ornatus) was used to test the AU because recent research has shown that during pregnancy the uterine fluid composition changes with mid- to late-term embryos immersed in seawater. An artificial uterine fluid comprising filtered, autoclaved seawater was placed in the AU. Eight, sexually mature female O. ornatus were captured from the wild and held in captivity. Subsequent ultrasound examinations confirmed pregnancy in three of these females. Six late-term embryos (three males and three females) were removed surgically from one euthanized female and placed in the AU. Their condition was monitored for 18 days before "birth" on September 26, 2008. The subsequent survival and growth of the AU pups was compared with naturally born wobbegong pups in captivity over a 140-day monitoring period. The development in the AU did not have detrimental effects as there was no postpartum mortality and there were marked increases in total length and weight that did not differ significantly between the two groups. © 2011 Wiley Periodicals, Inc.
Noninvasive biosensor and wireless interrogating system for glucose in blood
NASA Astrophysics Data System (ADS)
Varadan, Vijay K.; Whitchurch, Ashwin K.; Sarukesi, K.
2003-07-01
Hypoglycemia-abnormal decrease in blood sugar-is a major obstacle in the management of diabetes and prevention of long-term complications, and it may impose serious effects on the brain, including impairment of memory and other cognitive functions. This paper presents the development of a non-invasive sensor with miniaturized telemetry device in a wrist-watch for monitoring glucose concentration in blood. The sensor concept is based on optical chirality of glucose level in the interstitial fluid. The wrist watch consists of a laser power source of the wavelength compatible with the glucose. A nanofilm with specific chirality is placed at the bottom of the watch. The light then passes through the film and illuminates a small area on the skin. It has been documented that there is certain concentration of sugar level is taken by the intertitial fluid from the blood stream and deposit a portion of it at the dead skin. The wrist-watch when in contact with the outer skin of the human will thus monitor the glucose concentration. A wireless monitoring system in the watch then downloads the data from the watch to a Palm or a laptop computer.
Non-invasive biosensor and wilreless interrogating system for hypoglycemia
NASA Astrophysics Data System (ADS)
Varadan, Vijay K.; Whitchurch, Ashwin K.; Saukesi, K.
2002-11-01
Hypoglycemia - abnormal decrease in blood sugar - is a major obstacle in the management of diabetes and prevention of long-term complications, and it may impose serious effects on the brain, including impairment of memory and other cognitive functions. This paper presents the development of a non-invasive sensor with miniaturized telemetry device in a wrist-watch for monitoring glucose concentration in blood. The sensor concept is based on optical chiralit of glucose level in the interstitial fluid. The wrist watch consists of a laser power source of the wavelength compatible with the glucose. A nanofilm with specific chirality is placed at the bottom of the watch. The light then passes through the film and illuminates a small area on the skin.It has been documented that there is certain concentration of sugar level is taken by the intertitial fluid from the blood stream and deposit a portion of it at the dead skin. The wrist-watch when in contact with the outer skin of the human will thus monitor the glucose concentration. A wireless monitoring system in the watch then downloads the data from the watch to a Palm or laptop computer.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Williams, Kenneth H.; Kemna, Andreas; Wilkins, Michael J.
2009-08-05
Understanding how microorganisms alter their physical and chemical environment during bioremediation is hindered by our inability to resolve subsurface microbial activity with high spatial resolution. Here we demonstrate the use of a minimally invasive geophysical technique to monitor stimulated microbial activity during acetate amendment in an aquifer near Rifle, Colorado. During electrical induced polarization (IP) measurements, spatiotemporal variations in the phase response between imposed electric current and the resultant electric field correlated with changes in groundwater geochemistry accompanying stimulated iron and sulfate reduction and sulfide mineral precipitation. The magnitude of the phase response varied with measurement frequency (0.125 and 1more » Hz) andwasdependent upon the dominant metabolic process. The spectral effect was corroborated using a biostimulated column experiment containing Rifle sediments and groundwater. Fluids and sediments recovered from regions exhibiting an anomalous phase response were enriched in Fe(II), dissolved sulfide, and cell-associated FeS nanoparticles. The accumulation of mineral precipitates and electroactive ions altered the ability of pore fluids to conduct electrical charge, accounting for the anomalous IP response and revealing the usefulness of multifrequency IP measurements for monitoring mineralogical and geochemical changes accompanying stimulated subsurface bioremediation.« less
Zhang, Zhongheng; Lu, Baolong; Sheng, Xiaoyan; Jin, Ni
2011-12-01
Stroke volume variation (SVV) appears to be a good predictor of fluid responsiveness in critically ill patients. However, a wide range of its predictive values has been reported in recent years. We therefore undertook a systematic review and meta-analysis of clinical trials that investigated the diagnostic value of SVV in predicting fluid responsiveness. Clinical investigations were identified from several sources, including MEDLINE, EMBASE, WANFANG, and CENTRAL. Original articles investigating the diagnostic value of SVV in predicting fluid responsiveness were considered to be eligible. Participants included critically ill patients in the intensive care unit (ICU) or operating room (OR) who require hemodynamic monitoring. A total of 568 patients from 23 studies were included in our final analysis. Baseline SVV was correlated to fluid responsiveness with a pooled correlation coefficient of 0.718. Across all settings, we found a diagnostic odds ratio of 18.4 for SVV to predict fluid responsiveness at a sensitivity of 0.81 and specificity of 0.80. The SVV was of diagnostic value for fluid responsiveness in OR or ICU patients monitored with the PiCCO or the FloTrac/Vigileo system, and in patients ventilated with tidal volume greater than 8 ml/kg. SVV is of diagnostic value in predicting fluid responsiveness in various settings.
NASA Astrophysics Data System (ADS)
Xie, Lei; Choi, Young-Tai; Liao, Chang-Rong; Wereley, Norman M.
2015-05-01
A key requirement for the commercialization of various magnetorheological fluid (MRF)-based applications is sedimentation stability. In this study, a high viscosity linear polysiloxane (HVLP), which has been used for shock absorbers in heavy equipment, is proposed as a new carrier fluid in highly stable MRFs. The HVLP is known to be a thixotropic (i.e., shear thinning) fluid that shows very high viscosity at very low shear rate and low viscosity at higher shear rate. In this study, using the shear rheometer, the significant thixotropic behavior of the HVLP was experimentally confirmed. In addition, a HVLP carrier fluid-based MRF (HVLP MRF) with 26 vol. % was synthesized and its sedimentation characteristics were experimentally investigated. But, because of the opacity of the HVLP MRF, no mudline can be visually observed. Hence, a vertical axis inductance monitoring system (VAIMS) applied to a circular column of fluid was used to evaluate sedimentation behavior by correlating measured inductance with the volume fraction of dispersed particles (i.e., Fe). Using the VAIMS, Fe concentration (i.e., volume fraction) was monitored for 28 days with a measurement taken every four days, as well as one measurement after 96 days to characterize long-term sedimentation stability. Finally, the concentration of the HVLP MRF as a function of the depth in the column and time, as well as the concentration change versus the depth in the column, are presented and compared with those of a commercially available MRF (i.e., Lord MRF-126CD).
Anastassiades, M; Schwack, W
1998-10-30
Simple methods for the analysis of carbendazim, benomyl and thiophanate methyl in fruits and vegetables and of 2,4-D in citrus fruits are presented. Sample preparation involves supercritical fluid extraction with carbon dioxide and further analysis is performed without any additional clean-up by GC-MS after derivatisation or directly by HPLC-diode array detection. The SFE methods presented are clearly faster and more cost effective than traditional solvent based approaches. The recoveries, detection limits and repeatabilities achieved, meet the needs of tolerance level monitoring of these compounds in fruits and vegetables.
Valeriani, Federica; Protano, Carmela; Gianfranceschi, Gianluca; Cozza, Paola; Campanella, Vincenzo; Liguori, Giorgio; Vitali, Matteo; Divizia, Maurizio; Romano Spica, Vincenzo
2016-08-09
Appropriate sanitation procedures and monitoring of their actual efficacy represent critical points for improving hygiene and reducing the risk of healthcare-associated infections. Presently, surveillance is based on traditional protocols and classical microbiology. Innovation in monitoring is required not only to enhance safety or speed up controls but also to prevent cross infections due to novel or uncultivable pathogens. In order to improve surveillance monitoring, we propose that biological fluid microflora (mf) on reprocessed devices is a potential indicator of sanitation failure, when tested by an mfDNA-based approach. The survey focused on oral microflora traces in dental care settings. Experimental tests (n = 48) and an "in field" trial (n = 83) were performed on dental instruments. Conventional microbiology and amplification of bacterial genes by multiple real-time PCR were applied to detect traces of salivary microflora. Six different sanitation protocols were considered. A monitoring protocol was developed and performance of the mfDNA assay was evaluated by sensitivity and specificity. Contaminated samples resulted positive for saliva traces by the proposed approach (CT < 35). In accordance with guidelines, only fully sanitized samples were considered negative (100 %). Culture-based tests confirmed disinfectant efficacy, but failed in detecting incomplete sanitation. The method provided sensitivity and specificity over 95 %. The principle of detecting biological fluids by mfDNA analysis seems promising for monitoring the effectiveness of instrument reprocessing. The molecular approach is simple, fast and can provide a valid support for surveillance in dental care or other hospital settings.
Hecking, Manfred; Antlanger, Marlies; Winnicki, Wolfgang; Reiter, Thomas; Werzowa, Johannes; Haidinger, Michael; Weichhart, Thomas; Polaschegg, Hans-Dietrich; Josten, Peter; Exner, Isabella; Lorenz-Turnheim, Katharina; Eigner, Manfred; Paul, Gernot; Klauser-Braun, Renate; Hörl, Walter H; Sunder-Plassmann, Gere; Säemann, Marcus D
2012-06-08
Data generated with the body composition monitor (BCM, Fresenius) show, based on bioimpedance technology, that chronic fluid overload in hemodialysis patients is associated with poor survival. However, removing excess fluid by lowering dry weight can be accompanied by intradialytic and postdialytic complications. Here, we aim at testing the hypothesis that, in comparison to conventional hemodialysis, blood volume-monitored regulation of ultrafiltration and dialysate conductivity (UCR) and/or regulation of ultrafiltration and temperature (UTR) will decrease complications when ultrafiltration volumes are systematically increased in fluid-overloaded hemodialysis patients. BCM measurements yield results on fluid overload (in liters), relative to extracellular water (ECW). In this prospective, multicenter, triple-arm, parallel-group, crossover, randomized, controlled clinical trial, we use BCM measurements, routinely introduced in our three maintenance hemodialysis centers shortly prior to the start of the study, to recruit sixty hemodialysis patients with fluid overload (defined as ≥15% ECW). Patients are randomized 1:1:1 into UCR, UTR and conventional hemodialysis groups. BCM-determined, 'final' dry weight is set to normohydration weight -7% of ECW postdialysis, and reached by reducing the previous dry weight, in steps of 0.1 kg per 10 kg body weight, during 12 hemodialysis sessions (one study phase). In case of intradialytic complications, dry weight reduction is decreased, according to a prespecified algorithm. A comparison of intra- and post-dialytic complications among study groups constitutes the primary endpoint. In addition, we will assess relative weight reduction, changes in residual renal function, quality of life measures, and predialysis levels of various laboratory parameters including C-reactive protein, troponin T, and N-terminal pro-B-type natriuretic peptide, before and after the first study phase (secondary outcome parameters). Patients are not requested to revert to their initial degree of fluid overload after each study phase. Therefore, the crossover design of the present study merely serves the purpose of secondary endpoint evaluation, for example to determine patient choice of treatment modality. Previous studies on blood volume monitoring have yielded inconsistent results. Since we include only patients with BCM-determined fluid overload, we expect a benefit for all study participants, due to strict fluid management, which decreases the mortality risk of hemodialysis patients. ClinicalTrials.gov, NCT01416753.
2012-01-01
Background Data generated with the body composition monitor (BCM, Fresenius) show, based on bioimpedance technology, that chronic fluid overload in hemodialysis patients is associated with poor survival. However, removing excess fluid by lowering dry weight can be accompanied by intradialytic and postdialytic complications. Here, we aim at testing the hypothesis that, in comparison to conventional hemodialysis, blood volume-monitored regulation of ultrafiltration and dialysate conductivity (UCR) and/or regulation of ultrafiltration and temperature (UTR) will decrease complications when ultrafiltration volumes are systematically increased in fluid-overloaded hemodialysis patients. Methods/design BCM measurements yield results on fluid overload (in liters), relative to extracellular water (ECW). In this prospective, multicenter, triple-arm, parallel-group, crossover, randomized, controlled clinical trial, we use BCM measurements, routinely introduced in our three maintenance hemodialysis centers shortly prior to the start of the study, to recruit sixty hemodialysis patients with fluid overload (defined as ≥15% ECW). Patients are randomized 1:1:1 into UCR, UTR and conventional hemodialysis groups. BCM-determined, ‘final’ dry weight is set to normohydration weight −7% of ECW postdialysis, and reached by reducing the previous dry weight, in steps of 0.1 kg per 10 kg body weight, during 12 hemodialysis sessions (one study phase). In case of intradialytic complications, dry weight reduction is decreased, according to a prespecified algorithm. A comparison of intra- and post-dialytic complications among study groups constitutes the primary endpoint. In addition, we will assess relative weight reduction, changes in residual renal function, quality of life measures, and predialysis levels of various laboratory parameters including C-reactive protein, troponin T, and N-terminal pro-B-type natriuretic peptide, before and after the first study phase (secondary outcome parameters). Discussion Patients are not requested to revert to their initial degree of fluid overload after each study phase. Therefore, the crossover design of the present study merely serves the purpose of secondary endpoint evaluation, for example to determine patient choice of treatment modality. Previous studies on blood volume monitoring have yielded inconsistent results. Since we include only patients with BCM-determined fluid overload, we expect a benefit for all study participants, due to strict fluid management, which decreases the mortality risk of hemodialysis patients. Trial registration ClinicalTrials.gov, NCT01416753 PMID:22682149
Effects of systemic L-tyrosine on dopamine release from rat corpus striatum and nucleus accumbens
NASA Technical Reports Server (NTRS)
During, Matthew J.; Acworth, Ian N.; Wurtman, Richard J.
1988-01-01
Intracerebral dialysis was used to monitor extracellular fluid from rat striatum and nucleus accumbens following the intraperitoneal administration of tyrosine. Dopamine concentrations in dialysates from both the striatum and the nucleus accumbens increased significantly in response to the tyrosine. The magnitude of the tyrosine effect was greater in the nucleus accumbens than in the striatum. Hence, mesolimbic dopaminergic neurons may be especially responsive to precursor availability.
Hydraulic pump with in-ground filtration and monitoring capability
Hopkins, C.D.; Livingston, R.R.; Toole, W.R. Jr.
1995-01-01
A hydraulically operated pump is described for in-ground filtering and monitoring of wells or other fluid sources, including a hollow cylindrical pump housing with an inlet and an outlet, filtering devices positioned in the inlet and the outlet, a piston that fits slidably within the pump housing, and an optical cell in fluid communication with the pump housing. A conduit within the piston allows fluid communication between the exterior and one end of the piston. A pair of O-rings form a seal between the inside of the pump housing and the exterior of the piston. A flow valve positioned within the piston inside the conduit allows fluid to flow in a single direction. In operation, fluid enters the pump housing through the inlet, flows through the conduit and towards an end of the pump housing. The piston then makes a downward stroke closing the valve, thus forcing the fluid out from the pump housing into the optical cell, which then takes spectrophotometric measurements of the fluid. A spring helps return the piston back to its starting position, so that a new supply of fluid may enter the pump housing and the downward stroke can begin again. The pump may be used independently of the optical cell, as a sample pump to transport a sample fluid from a source to a container for later analysis.
Hydraulic pump with in-ground filtration and monitoring capability
Hopkins, C.D.; Livingston, R.R.; Toole, W.R. Jr.
1996-10-29
A hydraulically operated pump is described for in-ground filtering and monitoring of waters or other fluid sources, includes a hollow cylindrical pump housing with an inlet and an outlet, filtering devices positioned in the inlet and the outlet, a piston that fits slidably within the pump housing, and an optical cell in fluid communication with the pump housing. A conduit within the piston allows fluid communication between the exterior and one end of the piston. A pair of o-rings form a seal between the inside of the pump housing and the exterior of the piston. A flow valve positioned within the piston inside the conduit allows fluid to flow in a single direction. In operation, fluid enters the pump housing through the inlet, flows through the conduit and towards an end of the pump housing. The piston then makes a downward stroke closing the valve, thus forcing the fluid out from the pump housing into the optical cell, which then takes spectrophotometric measurements of the fluid. A spring helps return the piston back to its starting position, so that a new supply of fluid may enter the pump housing and the downward stroke can begin again. The pump may be used independently of the optical cell, as a sample pump to transport a sample fluid from a source to a container for later analysis. 5 figs.
Hydraulic pump with in-ground filtration and monitoring capability
Hopkins, Charles D.; Livingston, Ronald R.; Toole, Jr., William R.
1996-01-01
A hydraulically operated pump for in-ground filtering and monitoring of ws or other fluid sources, including a hollow cylindrical pump housing with an inlet and an outlet, filtering devices positioned in the inlet and the outlet, a piston that fits slidably within the pump housing, and an optical cell in fluid communication with the pump housing. A conduit within the piston allows fluid communication between the exterior and one end of the piston. A pair of o-rings form a seal between the inside of the pump housing and the exterior of the piston. A flow valve positioned within the piston inside the conduit allows fluid to flow in a single direction. In operation, fluid enters the pump housing through the inlet, flows through the conduit and towards an end of the pump housing. The piston then makes a downward stroke closing the valve, thus forcing the fluid out from the pump housing into the optical cell, which then takes spectrophotometric measurements of the fluid. A spring helps return the piston back to its starting position, so that a new supply of fluid may enter the pump housing and the downward stroke can begin again. The pump may be used independently of the optical cell, as a sample pump to transport a sample fluid from a source to a container for later analysis.
Ronco, Claudio; Kaushik, Manish; Valle, Roberto; Aspromonte, Nadia; Peacock, W Frank
2012-01-01
Cardio-Renal syndrome may occur as a result of either primarily renal or cardiac dysfunction. This complex interaction requires a tailored approach to manage the underlying pathophysiology while optimizing the patient's symptoms and thus providing the best outcomes. Patients often are admitted to the hospital for signs and symptoms of congestion and fluid overload is the most frequent cause of subsequent re-admission. Fluid management is of paramount importance in the strategy of treatment for heart failure patients. Adequate fluid status should be obtained but a target value should be set according to objective indicators and biomarkers. Once the fluid excess is identified, a careful prescription of fluid removal by diuretics or extracorporeal therapies must be made. While delivering these therapies, adequate monitoring should be performed to prevent unwanted effects such as worsening of renal function or other complications. There is a very narrow window of optimal hydration for heart failure patients. Overhydration can result in myocardial stretching and potential decompensation. Inappropriate dehydration or relative reduction of circulating blood volume may result in distant organ damage caused by inadequate perfusion. We suggest consideration of the "5B" approach. This stands for balance of fluids (reflected by body weight), blood pressure, biomarkers, bioimpedance vector analysis, and blood volume. Addressing these parameters ensures that the most important issues affecting symptoms and outcomes are addressed. Furthermore, the patient is receiving the best possible care while avoiding unwanted side effects of the treatment. Copyright © 2012 Elsevier Inc. All rights reserved.
Anesthetic management of intestinal obstruction: A postgraduate educational review.
Parthasarathy, S; Sripriya, R; Krishnaveni, N
2016-01-01
Intestinal obstruction is associated with significant morbidity and mortality. Scientific assessment of the cause, site of obstruction, appropriate correction of the fluid deficit and electrolyte imbalance with preoperative stabilization of blood gases is ideal as a preoperative workup. Placement of a preoperative epidural catheter especially in the thoracic interspace takes care of perioperative pain and stress reduction. Intraoperative management by controlled general anesthesia administering a relative high inspired fraction of oxygen with invasive monitoring in selected sick cases is mandatory. Preoperative monitoring and stabilizing raised intra-abdominal pressure reduces morbidity. Caution should be exercised during opening and closure of abdomen to avoid cardiorespiratory ill effects. There should be an emphasis on avoiding hypothermia. The use of nonsteroidal anti-inflammatory drugs may worsen sick, fragile patients. The use of sugammadex rather than neostigmine will obscure certain controversies in the healing of intestinal anastomotic site. Replacement of blood loss continued correction of fluids and electrolytes with possible postoperative mechanical ventilation in sick cases may improve outcomes in these patients.
Current techniques in acid-chloride corrosion control and monitoring at The Geysers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hirtz, Paul; Buck, Cliff; Kunzman, Russell
1991-01-01
Acid chloride corrosion of geothermal well casings, production piping and power plant equipment has resulted in costly corrosion damage, frequent curtailments of power plants and the permanent shut-in of wells in certain areas of The Geysers. Techniques have been developed to mitigate these corrosion problems, allowing continued production of steam from high chloride wells with minimal impact on production and power generation facilities.The optimization of water and caustic steam scrubbing, steam/liquid separation and process fluid chemistry has led to effective and reliable corrosion mitigation systems currently in routine use at The Geysers. When properly operated, these systems can yield steammore » purities equal to or greater than those encountered in areas of The Geysers where chloride corrosion is not a problem. Developments in corrosion monitoring techniques, steam sampling and analytical methodologies for trace impurities, and computer modeling of the fluid chemistry has been instrumental in the success of this technology.« less
Love, T D; Baker, D F; Healey, P; Black, K E
2018-04-01
To determine athletes perceived and measured indices of fluid balance during training and the influence of hydration strategy use on these parameters. Thirty-three professional rugby union players completed a 120 minute training session in hot conditions (35°C, 40% relative humidity). Pre-training hydration status, sweat loss, fluid intake and changes in body mass (BM) were obtained. The use of hydration assessment techniques and players perceptions of fluid intake and sweat loss were obtained via a questionnaire. The majority of players (78%) used urine colour to determine pre-training hydration status but the use of hydration assessment techniques did not influence pre-training hydration status (1.025 ± 0.005 vs. 1.023 ± 0.013 g . ml -1 , P = .811). Players underestimated sweat loss (73 ± 17%) to a greater extent than fluid intake (37 ± 28%) which resulted in players perceiving they were in positive fluid balance (0.5 ± 0.8% BM) rather than the measured negative fluid balance (-1.0 ± 0.7% BM). Forty-eight percent of players used hydration monitoring strategies during exercise but no player used changes in BM to help guide fluid replacement. Players have difficulty perceiving fluid intake and sweat loss during training. However, the use of hydration monitoring techniques did not affect fluid balance before or during training.
NASA Astrophysics Data System (ADS)
Munaka, Tatsuya; Abe, Hirohisa; Kanai, Masaki; Sakamoto, Takashi; Nakanishi, Hiroaki; Yamaoka, Tetsuji; Shoji, Shuichi; Murakami, Akira
2006-07-01
We successfully developed a measurement system for real-time analysis of cellular function using a newly designed microchip. This microchip was equipped with a micro cell incubation chamber (240 nl) and was stimulated by a very small amount of stimuli (as small as 24 nl). Using the microchip system, cultivation of mast cells was successfully carried out. Monitoring of the cellular events after stimulation with an extremely small amount of fluid on a microchip was performed. This system could be applicable for various types of cellular analysis including real-time monitoring of cellular response by stimulation.
Solids mass flow determination
Macko, Joseph E.
1981-01-01
Method and apparatus for determining the mass flow rate of solids mixed with a transport fluid to form a flowing mixture. A temperature differential is established between the solids and fluid. The temperature of the transport fluid prior to mixing, the temperature of the solids prior to mixing, and the equilibrium temperature of the mixture are monitored and correlated in a heat balance with the heat capacities of the solids and fluid to determine the solids mass flow rate.
Geochemical monitoring of drilling fluids; A powerful tool to forecast and detect formation waters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vuataz, F.D.; Brach, M.; Criaud, A.
1990-06-01
This paper describes a method based on the difference between the chemical compositions of formation and drilling fluids for analyzing drilling mud to forecast fluid-producing zones. The method was successfully applied in three boreholes in crystalline rocks in France. Subsequent geophysical logs and hydraulic tests confirmed the occurrence of flowing fractures.
Wave Velocities in Hydrocarbons and Hydrocarbon Saturated - Applications to Eor Monitoring.
NASA Astrophysics Data System (ADS)
Wang, Zhijing
In order to effectively utilize many new seismic technologies and interpret the results, acoustic properties of both reservoir fluids and rocks must be well understood. It is the main purpose of this dissertation to investigate acoustic wave velocities in different hydrocarbons and hydrocarbon saturated rocks under various reservoir conditions. The investigation consists of six laboratory experiments, followed by a series of theoretical and application analyses. All the experiments involve acoustic velocity measurements in hydrocarbons and rocks with different hydrocarbons, using the ultrasonic pulse-transmission methods, at elevated temperatures and pressures. In the experiments, wave velocities are measured versus both temperature and pressure in 50 hydrocarbons. The relations among the acoustic velocity, temperature, pressure, API gravity, and the molecular weight of the hydrocarbons are studied, and empirical equations are established which allow one to calculate the acoustic velocities in hydrocarbons with known API gravities. Wave velocities in hydrocarbon mixtures are related to the composition and the velocities in the components. The experimental results are also analyzed in terms of various existing theories and models of the liquid state. Wave velocities are also measured in various rocks saturated with different hydrocarbons. The compressional wave velocities in rocks saturated with pure hydrocarbons increase with increasing the carbon number of the hydrocarbons. They decrease markedly in all the heavy hydrocarbon saturated rocks as temperature increases. Such velocity decreases set the petrophysical basis for in-situ seismic monitoring thermal enhanced oil recovery processes. The effects of carbon dioxide flooding and different pore fluids on wave velocities in rocks are also investigated. It is highly possible that there exist reflections of seismic waves at the light-heavy oil saturation interfaces in-situ. It is also possible to use seismic methods to monitor carbon dioxide flooding processes. Velocity dispersions are analyzed theoretically in rocks saturated with different pore fluids. The results are discussed in terms of the Biot theory and the "local flow" mechanism. Applications of the results and the applicability of using seismic methods to monitor various enhanced oil recovery and production processes are also discussed.
Extended Detection of Amphetamine and Methamphetamine in Oral Fluid.
Andås, Hilde T; Enger, Asle; Øiestad, Åse Marit L; Vindenes, Vigdis; Christophersen, Asbjørg S; Huestis, Marilyn A; Øiestad, Elisabeth L
2016-02-01
Amphetamine and methamphetamine are popular drugs of abuse worldwide and are important components of drug monitoring programs. Windows of detection for amphetamine and methamphetamine in oral fluid after high doses have not been investigated. Repeated high-dose ingestions are likely to cause positive samples for extended periods. Common routes of administration of amphetamine/methamphetamine in Norway are oral intake or injection. The aim of this study was to investigate windows of detection for amphetamine and methamphetamine in oral fluid from drug addicts under sustained abstinence during detoxification. Twenty-five patients admitted to a closed detoxification unit were included in this study. Oral fluid samples were collected daily in the morning and evening, and urine every morning for 10 days. A blood sample was drawn during the first 5 days after admission if the patient consented. Oral fluid results were compared with urine results to determine whether a new ingestion occurred. Oral fluid was collected with the Intercept oral fluid collection device. In-house cutoff concentrations for amphetamine and methamphetamine were 6.8 and 7.5 mcg/L, respectively, in oral fluid, and 135 and 149 mcg/L, respectively, in urine. Amphetamines were detected in 11 oral fluid, 5 urine, and 2 blood specimens from 25 patients. Patients self-reported amphetamines intake of up to 0.5-2 g daily. Windows of detection for amphetamine and methamphetamine in oral fluid were up to 8 days, longer than in urine at the applied cutoff values. These data confirm that oral fluid is a viable alternative to urine for monitoring amphetamine abuse, and that these substances might be detected in oral fluid for at least 1 week after ingestion of high doses. Such long detection times were, as far as we are aware, never reported previously for oral fluid amphetamines.
The detection of pleural effusion using a parametric EIT technique.
Arad, M; Zlochiver, S; Davidson, T; Shoenfeld, Y; Adunsky, A; Abboud, S
2009-04-01
The bioimpedance technique provides a safe, low-cost and non-invasive alternative for routine monitoring of lung fluid levels in patients. In this study we have investigated the feasibility of bioimpedance measurements to monitor pleural effusion (PE) patients. The measurement system (eight-electrode thoracic belt, opposite sequential current injections, 3 mA, 20 kHz) employed a parametric reconstruction algorithm to assess the left and right lung resistivity values. Bioimpedance measurements were taken before and after the removal of pleural fluids, while the patient was sitting at rest during tidal respiration in order to minimize movements of the thoracic cavity. The mean resistivity difference between the lung on the side with PE and the lung on the other side was -48 Omega cm. A high correlation was found between the mean lung resistivity value before the removal of the fluids and the volume of pleural fluids removed, with a sensitivity of -0.17 Omega cm ml(-1) (linear regression, R=0.53). The present study further supports the feasibility and applicability of the bioimpedance technique, and specifically the approach of parametric left and right lung resistivity reconstruction, in monitoring lung patients.
Ito, N; Saito, A; Kayashima, S; Kimura, J; Kuriyama, T; Nagata, N; Arai, T; Kikuchi, M
1995-01-01
A transcutaneous blood glucose monitoring system consists of an ion-sensitive field-effect transistor (ISFET) glucose sensor unit and a suction effusion fluid (SEF) collecting unit. The SEF is directly collected by a weak suction (400 mmHg absolute pressure) through the skin from which the corneum layer of the epidermis has been previously removed. An ISFET glucose sensor unit is able to measure glucose concentrations in a microliter order sampling volume. The system was applied to three diabetic patients during a 75 g oral glucose tolerance test for monitoring blood glucose levels. During the experiments, glucose changes in the SEF followed actual blood glucose levels with 10 min delays. Results suggest the feasibility of utilizing quasi-continuous, transcutaneous blood glucose monitoring for individual patients with various diabetic histories or diabetic complications.
Replaceable Sensor System for Bioreactor Monitoring
NASA Technical Reports Server (NTRS)
Mayo, Mike; Savoy, Steve; Bruno, John
2006-01-01
A sensor system was proposed that would monitor spaceflight bioreactor parameters. Not only will this technology be invaluable in the space program for which it was developed, it will find applications in medical science and industrial laboratories as well. Using frequency-domain-based fluorescence lifetime technology, the sensor system will be able to detect changes in fluorescence lifetime quenching that results from displacement of fluorophorelabeled receptors bound to target ligands. This device will be used to monitor and regulate bioreactor parameters including glucose, pH, oxygen pressure (pO2), and carbon dioxide pressure (pCO2). Moreover, these biosensor fluorophore receptor-quenching complexes can be designed to further detect and monitor for potential biohazards, bioproducts, or bioimpurities. Biosensors used to detect biological fluid constituents have already been developed that employ a number of strategies, including invasive microelectrodes (e.g., dark electrodes), optical techniques including fluorescence, and membrane permeable systems based on osmotic pressure. Yet the longevity of any of these sensors does not meet the demands of extended use in spacecraft habitat or bioreactor monitoring. It was therefore necessary to develop a sensor platform that could determine not only fluid variables such as glucose concentration, pO2, pCO2, and pH but can also regulate these fluid variables with controlled feedback loop.
Fluid Biomarkers in Alzheimer Disease
Blennow, Kaj; Zetterberg, Henrik; Fagan, Anne M.
2012-01-01
Research progress has provided detailed understanding of the molecular pathogenesis of Alzheimer disease (AD). This knowledge has been translated into new drug candidates with putative disease-modifying effects, which are now being tested in clinical trials. The promise of effective therapy has created a great need for biomarkers able to detect AD in the predementia phase, because drugs will probably be effective only if neurodegeneration is not too advanced. In this chapter, cerebrospinal fluid (CSF) and plasma biomarkers are reviewed. The core CSF biomarkers total tau (T-tau), phosphorylated tau (P-tau) and the 42 amino acid form of β-amyloid (Aβ42) reflect AD pathology, and have high diagnostic accuracy to diagnose AD with dementia and prodromal AD in mild cognitive impairment cases. The rationale for the use of CSF biomarkers to identify and monitor the mechanism of action of new drug candidates is also outlined in this chapter. PMID:22951438
NASA Astrophysics Data System (ADS)
Kusagaya, T.; Uchida, T.; Tanaka, H. K. M.; Tanaka, M.
2012-04-01
We will present a real-time monitoring system for cosmic-ray muon radiography as an application of a readout module developed by T. Uchida et al [1,2]. The readout module was developed originally for probing the internal structure of volcanoes in 2008 [3]. Its features are small in size, low power consumption, and the capability to access remotely via Ethernet. The current statistics data of cosmic-ray muons can be read from a PC placed far from the module at anytime. By using this feature, we constructed a real-time monitoring system. As a test experiment, we observed fluid movement in a cylinder with a diameter of 112 meters water equivalent. In this work, we succeeded to resolve the fluid movement in the cylinder. We varied the fluid level inside the cylinder and measured the muon intensity. We found that the muon intensity correlates inversely with the fluid level: the muon intensity increases for the lower fluid level and decreases for the higher fluid level. Although the time resolution of muon radiography was sufficient to resolve changes in the fluid level, an adequate time window has to be chosen for different operating conditions. We anticipate that this system will be applicable to exploring high-speed phenomena in a gigantic object.
Non-Invasive Electromagnetic Skin Patch Sensor to Measure Intracranial Fluid–Volume Shifts
Griffith, Jacob; Cluff, Kim; Eckerman, Brandon; Aldrich, Jessica; Becker, Ryan; Moore-Jansen, Peer; Patterson, Jeremy
2018-01-01
Elevated intracranial fluid volume can drive intracranial pressure increases, which can potentially result in numerous neurological complications or death. This study’s focus was to develop a passive skin patch sensor for the head that would non-invasively measure cranial fluid volume shifts. The sensor consists of a single baseline component configured into a rectangular planar spiral with a self-resonant frequency response when impinged upon by external radio frequency sweeps. Fluid volume changes (10 mL increments) were detected through cranial bone using the sensor on a dry human skull model. Preliminary human tests utilized two sensors to determine feasibility of detecting fluid volume shifts in the complex environment of the human body. The correlation between fluid volume changes and shifts in the first resonance frequency using the dry human skull was classified as a second order polynomial with R2 = 0.97. During preliminary and secondary human tests, a ≈24 MHz and an average of ≈45.07 MHz shifts in the principal resonant frequency were measured respectively, corresponding to the induced cephalad bio-fluid shifts. This electromagnetic resonant sensor may provide a non-invasive method to monitor shifts in fluid volume and assist with medical scenarios including stroke, cerebral hemorrhage, concussion, or monitoring intracranial pressure. PMID:29596338
Effect of the Dialysis Fluid Buffer on Peritoneal Membrane Function in Children
Nau, Barbara; Gemulla, Gita; Bonzel, Klaus E.; Hölttä, Tuula; Testa, Sara; Fischbach, Michel; John, Ulrike; Kemper, Markus J.; Sander, Anja; Arbeiter, Klaus; Schaefer, Franz
2013-01-01
Summary Background and objectives Double-chamber peritoneal dialysis fluids exert less toxicity by their neutral pH and reduced glucose degradation product content. The role of the buffer compound (lactate and bicarbonate) has not been defined in humans. Design, setting, participants, & measurements A multicenter randomized controlled trial in 37 children on automated peritoneal dialysis was performed. After a 2-month run-in period with conventional peritoneal dialysis fluids, patients were randomized to neutral-pH, low-glucose degradation product peritoneal dialysis fluids with 35 mM lactate or 34 mM bicarbonate content. Clinical and biochemical monitoring was performed monthly, and peritoneal equilibration tests and 24-hour clearance studies were performed at 0, 3, 6, and 10 months. Results No statistically significant difference in capillary blood pH, serum bicarbonate, or oral buffer supplementation emerged during the study. At baseline, peritoneal solute equilibration and clearance rates were similar. During the study, 4-hour dialysis to plasma ratio of creatinine tended to increase, and 24-hour dialytic creatinine and phosphate clearance increased with lactate peritoneal dialysis fluid but not with bicarbonate peritoneal dialysis fluid. Daily net ultrafiltration, which was similar at baseline (lactate fluid=5.4±2.6 ml/g glucose exposure, bicarbonate fluid=4.9±1.9 ml/g glucose exposure), decreased to 4.6±1.0 ml/g glucose exposure in the lactate peritoneal dialysis fluid group, whereas it increased to 5.1±1.7 ml/g glucose exposure in the bicarbonate content peritoneal dialysis fluid group (P=0.006 for interaction). Conclusions When using biocompatible peritoneal dialysis fluids, equally good acidosis control is achieved with lactate and bicarbonate buffers. Improved long-term preservation of peritoneal membrane function may, however, be achieved with bicarbonate-based peritoneal dialysis fluids. PMID:23124784
Fantoni, Denise; Shih, Andre C
2017-03-01
Anesthesia can lead to pathophysiologic changes that dramatically alter the fluid balance of the body compartments and the intravascular space. Fluid administration can be monitored and evaluated using static and dynamic indexes. Guidelines for fluid rates during anesthesia begin with 3 mL/kg/h in cats and 5 mL/kg/h in dogs. If at all possible, patients should be stabilized and electrolyte disturbances should be corrected before general anesthesia. Copyright © 2016 Elsevier Inc. All rights reserved.
Bowel perforation detection using metabolic fluorescent chlorophylls
NASA Astrophysics Data System (ADS)
Han, Jung Hyun; Jo, Young Goun; Kim, Jung Chul; Choi, Sujeong; Kang, Hoonsoo; Kim, Yong-Chul; Hwang, In-Wook
2016-03-01
Thus far, there have been tries of detection of disease using fluorescent materials. We introduce the chlorophyll derivatives from food plants, which have longer-wavelength emissions (at >650 nm) than those of fluorescence of tissues and organs, for detection of bowel perforation. To figure out the possibility of fluorescence spectroscopy as a monitoring sensor of bowel perforation, fluorescence from organs of rodent models, intestinal and peritoneal fluids of rodent models and human were analyzed. In IVIS fluorescence image of rodent abdominal organ, visualization of perforated area only was possible when threshold of image is extremely finely controlled. Generally, both perforated area of bowel and normal bowel which filled with large amount of chlorophyll derivatives were visualized with fluorescence. The fluorescence from chlorophyll derivatives penetrated through the normal bowel wall makes difficult to distinguish perforation area from normal bowel with direct visualization of fluorescence. However, intestinal fluids containing chlorophyll derivatives from food contents can leak from perforation sites in situation of bowel perforation. It may show brighter and longer-wavelength regime emissions of chlorophyll derivatives than those of pure peritoneal fluid or bioorgans. Peritoneal fluid mixed with intestinal fluids show much brighter emissions in longer wavelength (at>650 nm) than those of pure peritoneal fluid. In addition, irrigation fluid, which is used for the cleansing of organ and peritoneal cavity, made of mixed intestinal and peritoneal fluid diluted with physiologic saline also can be monitored bowel perforation during surgery.
Method and Apparatus for Measuring Fluid Flow
NASA Technical Reports Server (NTRS)
Arndt, G. Dickey (Inventor); Nguyen, Than X. (Inventor); Carl, James R. (Inventor)
1995-01-01
The invention is a method and apparatus for monitoring the presence, concentration, and the movement of fluids. It is based on utilizing electromagnetic measurements of the complex permittivity of the fluids for detecting and monitoring the fluid. More particularly the apparatus uses one or more microwave probes which are placed at the locations where the measurements are to be made. A radio frequency signal is transmitted to the probe and the reflected signal is phase and amplitude detected at a rapid rate for the purpose of identifying the fluids, based on their dielectric constant at the probe. The apparatus can be used for multiple purposes including measures of flow rates, turbulence, dispersion, fluid identification, and changes in flow conditions of multiple fluids or multiple states of a single fluid in a flowline or a holding container. The apparatus includes a probe consisting of two electrical conductors separated by an insulator. A radio frequency signal is communicated to the probe and is reflected back from the portion of the probe exposed to the fluid. The radio frequency signal also provides a reference signal. An oscillator generates a second signal which combined with each of the reference signal and the reflected signal to produce signals of lower frequencies to facilitate filtering and amplifying those signals. The two signals are then mixed in a detector to produce an output signal that is representative of the phase and amplitude change caused by the reflection of the signal at the probe exposed to the fluid. The detector may be a dual phase detector that provides two such output signals that are in phase quadrature. A phase shifter may be provided for selectively changing the phase of the reference signal to improve the sensitivity of at least one of the output signals for more accurate readings and/or for calibration purposes. The two outputs that are in quadrature with respect to each other may be simultaneously monitored to account for drift errors. The output signals are digitized and provided to a computer at a sample rate which may be very high. The computer is operable to identify the fluid based on its complex permittivity as may be useful for identifying the flow rates, determining the fluid mixture ratio, detecting impurities in the fluid, and so forth. Novelty is believed to reside in the use of the real part of complex permittivity to measure small difference in permittivity of the fluid.
Grain scale observations of stick-slip dynamics in fluid saturated granular fault gouge
NASA Astrophysics Data System (ADS)
Johnson, P. A.; Dorostkar, O.; Guyer, R. A.; Marone, C.; Carmeliet, J.
2017-12-01
We are studying granular mechanics during slip. In the present work, we conduct coupled computational fluid dynamics (CFD) and discrete element method (DEM) simulations to study grain scale characteristics of slip instabilities in fluid saturated granular fault gouge. The granular sample is confined with constant normal load (10 MPa), and sheared with constant velocity (0.6 mm/s). This loading configuration is chosen to promote stick-slip dynamics, based on a phase-space study. Fluid is introduced in the beginning of stick phase and characteristics of slip events i.e. macroscopic friction coefficient, kinetic energy and layer thickness are monitored. At the grain scale, we monitor particle coordination number, fluid-particle interaction forces as well as particle and fluid kinetic energy. Our observations show that presence of fluids in a drained granular fault gouge stabilizes the layer in the stick phase and increases the recurrence time. In saturated model, we observe that average particle coordination number reaches higher values compared to dry granular gouge. Upon slip, we observe that a larger portion of the granular sample is mobilized in saturated gouge compared to dry system. We also observe that regions with high particle kinetic energy are correlated with zones of high fluid motion. Our observations highlight that spatiotemporal profile of fluid dynamic pressure affects the characteristics of slip instabilities, increasing macroscopic friction coefficient drop, kinetic energy release and granular layer compaction. We show that numerical simulations help characterize the micromechanics of fault mechanics.
Angel, S.M.
1987-02-27
Particular gases or liquids are detected with a fiber optic element having a cladding or coating of a material which absorbs the fluid or fluids and which exhibits a change of an optical property, such as index of refraction, light transmissiveness or fluoresence emission, for example, in response to absorption of the fluid. The fluid is sensed by directing light into the fiber optic element and detecting changes in the light, such as exit angle changes for example, that result from the changed optical property of the coating material. The fluid detector may be used for such purposes as sensing toxic or explosive gases in the atmosphere, measuring ground water contamination or monitoring fluid flows in industrial processes, among other uses. 10 figs.
Absorption-emission optrode and methods of use thereof
Hirschfeld, T.B.
1990-05-29
A method and apparatus are described for monitoring the physical and chemical properties of a sample fluid by measuring an optical signal generated by a fluorescent substance and modulated by an absorber substance. The emission band of the fluorescent substance overlaps the absorption band of the absorber substance, and the degree of overlap is dependent on the physical and chemical properties of the sample fluid. The fluorescent substance and absorber substance are immobilized on a substrate so that an effective number of molecules thereof are sufficiently close for resonant energy transfer to occur, thereby providing highly efficient modulation of the fluorescent emissions of the fluorescent substance by the absorber substance. 4 figs.
Fluid and electrolyte disturbances in critically ill patients.
Lee, Jay Wook
2010-12-01
Disturbances in fluid and electrolytes are among the most common clinical problems encountered in the intensive care unit (ICU). Recent studies have reported that fluid and electrolyte imbalances are associated with increased morbidity and mortality among critically ill patients. To provide optimal care, health care providers should be familiar with the principles and practice of fluid and electrolyte physiology and pathophysiology. Fluid resuscitation should be aimed at restoration of normal hemodynamics and tissue perfusion. Early goal-directed therapy has been shown to be effective in patients with severe sepsis or septic shock. On the other hand, liberal fluid administration is associated with adverse outcomes such as prolonged stay in the ICU, higher cost of care, and increased mortality. Development of hyponatremia in critically ill patients is associated with disturbances in the renal mechanism of urinary dilution. Removal of nonosmotic stimuli for vasopressin secretion, judicious use of hypertonic saline, and close monitoring of plasma and urine electrolytes are essential components of therapy. Hypernatremia is associated with cellular dehydration and central nervous system damage. Water deficit should be corrected with hypotonic fluid, and ongoing water loss should be taken into account. Cardiac manifestations should be identified and treated before initiating stepwise diagnostic evaluation of dyskalemias. Divalent ion deficiencies such as hypocalcemia, hypomagnesemia and hypophosphatemia should be identified and corrected, since they are associated with increased adverse events among critically ill patients.
NASA Astrophysics Data System (ADS)
Kwon, Tae Yun; Eom, Kilho; Park, Jae Hong; Yoon, Dae Sung; Kim, Tae Song; Lee, Hong Lim
2007-05-01
The authors report the precise (noise-free) in situ real-time monitoring of a specific protein antigen-antibody interaction by using a resonating microcantilever immersed in a viscous fluid. In this work, they utilized a resonating piezoelectric thick film microcantilever, which exhibits the high quality factor (e.g., Q =15) in a viscous liquid at a viscosity comparable to that of human blood serum. This implies a great potential of the resonating microcantilever to in situ biosensor applications. It is shown that the microcantilever enables them to monitor the C reactive protein antigen-antibody interactions in real time, providing an insight into the protein binding kinetics.
Education on fluid management and encouraging critical thinking skills.
Dale, Willette
2012-01-01
The unit is currently utilizing hematocrit-based blood volume monitoring on each patient, resulting in improved monitoring in patients achieving their target weight. The nurses expressed confidence in their understanding of the use of hematocrit-based blood volume monitoring. This learning experience provided a vivid look at the importance of fluid management in nephrology nursing. This area should always be included in nephrology nurse competencies and represented in a way that it ignites critical thinking within the nursing professional. It is the responsibility of a professional nurse to stay current in evidence-based practice and continuing education. Professional pride stimulates nephrology nurses to seek new learning experiences to enhance their practice.
NASA Technical Reports Server (NTRS)
Cowings, Patricia; Toscano, William; Kanis, Dionisios; Gebreyesus, Fiyore
2013-01-01
Susceptibility of healthy astronauts to orthostatic hypotension and presyncope is exacerbated upon return from spaceflight. Hypo-volemia is suspected to play an important role in cardiovascular deconditioning following exposure to spaceflight, which may lead to increased peripheral resistance, attenuated arterial baroreflex, and changes in cardiac function. The effect of altered gravity during space flight and planetary transition on human cardiovascular function is of critical importance to maintenance of astronaut health and safety. A promising countermeasure for post-flight orthostatic intolerance is fluid loading used to restore loss fluid volume by giving crew salt tablets and water prior to re-entry. Eight men and eight women will be tested during two, 6-hour exposures to 6o HDT: 1) fluid loading, 2) no fluid loading. Before and immediately after each HDT, subjects will perform a stand test to assess their orthostatic tolerance. Physiological measures (e.g., ECG, blood pressure, peripheral blood volume) will be continuously monitored while echocardiography measures are recorded at 30-minute intervals during HDT and stand tests. Preliminary results (N=4) clearly show individual differences in responses to this countermeasure and the time course of physiological changes induced by HDT.
Monitoring Fluid Flow in Fractured Carbonate Rocks Using Seismic Measurements
NASA Astrophysics Data System (ADS)
Li, W.; Pyrak-Nolte, L. J.
2008-12-01
The physical properties of carbonate rock are strongly influenced by the rock fabric which depends on the depositional environment, diagenetic and tectonic processes. The most common form of heterogeneity is layering caused by a variation in porosity among layers and within layers. The variation in porosity among layers leads to anisotropic behavior in the hydraulic, mechanical and seismic properties of carbonate rocks. We present the results of a laboratory study to examine the effect of fabric-controlled layering on fluid flow and seismic wave propagation through intact and fractured carbonate rock. Experiments were performed on cubic samples of Austin Chalk Cordova Cream. Samples AC1, AC5 and AC6 are cubic samples that measure 100 mm on edge. The samples were sealed and contained three inlet and three outlet ports for fluid invasion experiments. Two orthogonal seismic arrays were used to record both compressional and shear wave transmission through intact and fractured samples. The arrays used piezoelectric contact transducers with a central frequency 1.0 MHz. Between the two arrays, sixteen sources and sixteen receivers were used. Seismic measurements were made on the samples as a function of stress and during fluid saturation. The location of the invading fluid front as a function of time was monitored by using the peak-to-peak amplitude of the transmitted signals. The front was assumed to be between a source-receiver pair when the signal amplitude decreased by 50% over the initial value. The hydraulic gradient was parallel and perpendicular to the layers for AC5 and AC6, respectively. Sample AC1 was fractured and flow ports were established on the edges of the fracture plane. The weakly directed fabric controlled the rate at which fluid flowed through the samples. From the seismic data on AC6, the fluid first spread vertically along a layer before flowing across the layers. For AC6, it took the fluid two and half hours to flow between the inlet and the outlet across the layers. However, for AC5, the water flowed quickly along the layers and crossed the entire sample in one and a half hours. From the seismic data on fractured sample AC1, the water initially took more than 15 hours to transverse the sample though portions of the fracture were invaded after two hours. No water was produced at the outlet over a 15 hour period. Upon inspection, chemical precipitation was observed along the fracture plane and fracture- matrix interaction controlled the saturation of the matrix. Seismic monitoring of the fluid-front during saturation indicates that fine bedding affects the hydraulic properties of the sample while geochemical interactions in fractures affect fracture-matrix communication. Acknowledgments: The authors wish to acknowledge support of this work by the Geosciences Research Program, Office of Basic Energy Sciences US Department of Energy (DEFG02-97ER14785 08) and by Exxon Mobil Upstream Research Company.
Hort, Ryan D; Revil, André; Munakata-Marr, Junko
2014-09-01
Time lapse resistivity surveys could potentially improve monitoring of permanganate-based in situ chemical oxidation (ISCO) of organic contaminants such as trichloroethene (TCE) by tracking changes in subsurface conductivity that result from injection of permanganate and oxidation of the contaminant. Bulk conductivity and pore fluid conductivity changes during unbuffered TCE oxidation using permanganate are examined through laboratory measurements and conductivity modeling using PHREEQC in fluid samples and porous media samples containing silica sand. In fluid samples, oxidation of one TCE molecule produces three chloride ions and one proton, resulting in an increase in fluid electrical conductivity despite the loss of two permanganate ions in the reaction. However, in saturated sand samples in which up to 8mM TCE was oxidized, at least 94% of the fluid conductivity associated with the presence of protons was removed within 3h of sand contact, most likely through protonation of silanol groups found on the surface of the sand grains. Minor conductivity effects most likely associated with pH-dependent reductive dissolution of manganese dioxide were also observed but not accounted for in pore-fluid conductivity modeling. Unaccounted conductivity effects resulted in an under-calculation of post-reaction pore fluid conductivity of 2.1% to 5.5%. Although small increases in the porous media formation factor resulting from precipitation of manganese dioxide were detected (about 3%), these increases could not be confirmed to be statistically significant. Both injection of permanganate and oxidation of TCE cause increases in bulk conductivity that would be detectable through time-lapse resistivity surveys in field conditions. Copyright © 2014 Elsevier B.V. All rights reserved.
HPLC analysis of 6-mercaptopurine and metabolites in extracellular body fluids.
Rudy, J L; Argyle, J C; Winick, N; Van Dreal, P
1988-09-01
A convenient HPLC assay, which allows for the simultaneous measurement in extracellular fluids of 6-mercaptopurine and four of its metabolites, 6-thioguanine, 6-mercaptopurine riboside, 6-thioxanthine and 6-thiouric acid is described. Solid phase extraction allows for the clean isolation of analytes from plasma, urine or cerebrospinal fluid. The simultaneous determination of 6-mercaptopurine and some of its major metabolites in extracellular fluids may contribute to the monitoring of patient compliance, bioavailability, and individual variation in metabolism and absorption.
Surface tension in human pathophysiology and its application as a medical diagnostic tool
Fathi-Azarbayjani, Anahita; Jouyban, Abolghasem
2015-01-01
Introduction: Pathological features of disease appear to be quite different. Despite this diversity, the common feature of various disorders underlies physicochemical and biochemical factors such as surface tension. Human biological fluids comprise various proteins and phospholipids which are capable of adsorption at fluid interfaces and play a vital role in the physiological function of human organs. Surface tension of body fluids correlates directly to the development of pathological states. Methods: In this review, the variety of human diseases mediated by the surface tension changes of biological phenomena and the failure of biological fluids to remain in their native state are discussed. Results: Dynamic surface tension measurements of human biological fluids depend on various parameters such as sex, age and changes during pregnancy or certain disease. It is expected that studies of surface tension behavior of human biological fluids will provide additional information and might become useful in medical practice. Theoretical background on surface tension measurement and surface tension values of reference fluids obtained from healthy and sick patients are depicted. Conclusion: It is well accepted that no single biomarker will be effective in clinical diagnosis. The surface tension measurement combined with routine lab tests may be a novel non-invasive method which can not only facilitate the discovery of diagnostic models for various diseases and its severity, but also be a useful tool for monitoring treatment efficacy. We therefore expect that studies of surface tension behavior of human biological fluids will provide additional useful information in medical practice. PMID:25901295
Reasenberg, Paul A.
1997-01-01
While the damaging effects of the earthquake represent a significant social setback and economic loss, the geophysical effects have produced a wealth of data that have provided important insights into the structure and mechanics of the San Andreas Fault system. Generally, the period after a large earthquake is vitally important to monitor. During this part of the seismic cycle, the primary fault and the surrounding faults, rock bodies, and crustal fluids rapidly readjust in response to the earthquake's sudden movement. Geophysical measurements made at this time can provide unique information about fundamental properties of the fault zone, including its state of stress and the geometry and frictional/rheological properties of the faults within it. Because postseismic readjustments are rapid compared with corresponding changes occurring in the preseismic period, the amount and rate of information that is available during the postseismic period is relatively high. From a geophysical viewpoint, the occurrence of the Loma Prieta earthquake in a section of the San Andreas fault zone that is surrounded by multiple and extensive geophysical monitoring networks has produced nothing less than a scientific bonanza. The reports assembled in this chapter collectively examine available geophysical observations made before and after the earthquake and model the earthquake's principal postseismic effects. The chapter covers four broad categories of postseismic effect: (1) aftershocks; (2) postseismic fault movements; (3) postseismic surface deformation; and (4) changes in electrical conductivity and crustal fluids.
Micromechanical transient sensor for measuring viscosity and density of a fluid
Thundat, Thomas G.; Oden, Patrick I.; Warmack, Robert J.; Finot, Eric Laurent
2001-01-01
A method and apparatus for measuring the viscosity and/or specific density of a fluid utilizes a microcantilever vibrated in the analyte fluid. The source of vibration is switched on and off and the transient behavior or decay in amplitude of the vibration is monitored. The method is particularly useful for the measurement of process conditions in remote locations in real time.
NASA Astrophysics Data System (ADS)
Yamamoto, Zulham; Jaafar, Ikmal Mohamad; Rohaya, M. A. W.; Abidin, Intan Zarina Zainol; Senafi, Sahidan; Ariffin, Zaidah Zainal; Ariffin, Shahrul Hisham Zainal
2013-11-01
Periodontal tissue changes exerted by external forces in orthodontic treatment allow tooth movement. The changes in periodontal tissues i.e. inflammation can be monitored using gingival crevicular fluid (GCF). GCF is a component of saliva. Saliva could be used to monitor periodontal disease progression. The use of saliva to monitor periodontal tissues changes during orthodontic treatment is still unknown. Therefore, we observed the profiles of inflammatory markers namely creatine kinase ('CK), nitric oxide (NO), lactate dehydrogenase (LDH) and aspartate aminotransferase (AST) in saliva of orthodontic patients to evaluate their importance in orthodontic treatment. A total of 21 subjects (13 female and 8 male) participated in this study. Samples were collected from gingival crevicular fluid at three period of archwire changes: baseline (M0), 2 weeks after 0.014" NiTi archwire (M1), and 2 weeks after 0.018" NiTi archwire (M2). All enzyme activities i.e. CK, LDH and AST were measured spectrophotometrically at 340 nm. Griess assay was used to measure nitric oxide level. CK activity, NO level, LDH activity and AST activity in saliva samples did not show significant differences among period of archwire changes. The use of inflammatory marker profiles in saliva may not represent the changes in periodontal tissues during orthodontic treatment.
Dopamine release in rat striatum - Physiological coupling to tyrosine supply
NASA Technical Reports Server (NTRS)
During, Matthew J.; Acworth, Ian N.; Wurtman, Richard J.
1989-01-01
Intracerebral microdialysis was used to monitor dopamine release in rat striatal extracellular fluid following the intraperitoneal administration of dopamine's precursor amino acid, L-tyrosine. Dopamine concentrations in dialysates increased transiently after tyrosine (50-100 mg/kg) administration. Pretreatment with haloperidol or the partial lesioning of nigrostriatal neurons enhanced the effect of tyrosine on dopamine release, and haloperidol also prolonged this effect. These data suggest that nigrostriatal dopaminergic neurons are responsive to changes in precursor availability under basal conditions, but that receptor-mediated feedback mechanisms limit the magnitude and duration of this effect.
Laboratory Investigation of the Effect of Water-Saturation on Seismic Wave Dispersion in Carbonates
NASA Astrophysics Data System (ADS)
Li, W.; Pyrak-Nolte, L. J.
2009-12-01
In subsurface rock, fluid content changes with time through natural causes or because of human interactions, such as extraction or sequestration of fluids. The ability to monitor, seismically, fluid migration in the subsurface requires an understanding of the effects that the degree of saturation and spatial distribution of fluids have on wave propagation in rock. In this study, we find that the seismic dispersion of a dry carbonate rock can be masked by saturating the sample. We used a laboratory mini-seismic array to monitor fluid invasion and withdrawal in a carbonate rock with fabric-controlled layering. Experiments were performed on prismatic samples of Austin Chalk measuring 50mm x 50mm x 100mm. The epoxy-sealed samples contained an inlet and an outlet port to enable fluid invasion/withdrawal along the long axis of the sample. Water was infused and withdrawn from the sample at a rate of 1ml/hr. The mini-seismic array consisted of a set of 12 piezoelectric contact transducers, each with a central frequency 1.0 MHz. Three compressional wave source-receiver pairs and three shear wave source-receiver pairs were used to probe along the length of the sample prior to invasion and during invasion and withdrawal of water from the sample. A pressure transducer was used to record the fluid pressure simultaneously with the full transmitted wave forms every 15-30 minutes. A wavelet analysis determined the effect of fluid invasion on velocity dispersion. We observed that the compressional wave dispersion was more sensitive to changes in saturation than the shear wave dispersion. When the sample was unsaturated, the high frequency components of the compressional wave (1.2MHz to 2MHz) had lower velocities (~ 2750m/s) than the low frequency components, which decrease monotonically from 2890 m/s for 0.2MHz to 1.2 MHz. As water infused the sample, the dispersion weakened. When the sample as fully saturated, the compressional wave velocity was frequency independent. The functional form of the dependence of the shear wave velocity on frequency is relatively constant with fluid saturation, but the magnitude of the velocity decreased (~35 m/s) with increasing saturation. From theoretical calculations, the shear modulus increased during water invasion and was independent of frequency. However, the changes in the Young’s modulus with water invasion depended on the frequency of observation. When 46.5ml was infused into the sample, the Young’s modulus interpreted from the high-frequency components (wavelength from 1.43mm to 2.4mm) increased 70%, while the modulus from the low-frequency components (wavelengths vary from 1.4cm to 3.4mm) increased between 20% and 55%. Interpreting seismic data to determine fluid saturation in rock with fabric-controlled layering requires an understanding of the seismic dispersion properties of the rock in addition to the ability of fluids on alter or mask the dispersion. Acknowledgments: The authors wish to acknowledge support of this work by the Geosciences Research Program, Office of Basic Energy Sciences US Department of Energy (DEFG02-97ER14785 08), by Exxon Mobil Upstream Research Company and the GeoMathematical Imaging Group at Purdue University.
Cardio-Pulmonary Stethoscope: Clinical Validation With Heart Failure and Hemodialysis Patients.
Iskander, Magdy F; Seto, Todd B; Perron, Ruthsenne Rg; Lim, Eunjung; Qazi, Farhan
2018-05-01
The purpose of this study is to evaluate the accuracy of a noninvasive radiofrequency-based device, the Cardio-Pulmonary Stethoscope (CPS), to monitor heart and respiration rates, and detect changes in lung water content in human experiments and clinical trials. Three human populations (healthy subjects ( ), heart failure (), and hemodialysis () patients) were enrolled in this study. The study was conducted at the University of Hawaii and the Queen's Medical Center in Honolulu, HI, USA. Measurement of heart and respiration rates for all patients was compared with standard FDA - approved monitoring methods. For lung water measurements, CPS data were compared with simultaneous pulmonary capillary wedge pressure (PCWP) measurements for heart failure patients, and with change in weight of extracted fluid for hemodialysis patients. Statistical correlation methods (Pearson, mixed, and intraclass) were used to compare the data and examine accuracy of CPS results. Results show that heart and respiration rates of all patients have excellent correlation factors, r≥0.9. Comparisons with fluid removed during hemodialysis treatment showed correlation factor of to 1, while PCWP measurements of heart failure patients had correlation factor of to 0.97. These results suggest that CPS technology accurately quantifies heart and respiration rates and measure fluid changes in the lungs. The CPS has the potential to accurately monitor lung fluid status noninvasively and continuously in a clinical and outpatient setting. Early and efficient management of lung fluid status is key in managing chronic conditions such heart failure, pulmonary hypertension, and acute respiration distress syndrome.
Effectiveness of a fluid chart in outpatient management of suspected dengue fever: A pilot study.
Nasir, Nazrila Hairin; Mohamad, Mohazmi; Lum, Lucy Chai See; Ng, Chirk Jenn
2017-01-01
Dengue infection is the fastest spreading mosquito-borne viral disease in the world. One of the complications of dengue is dehydration which, if not carefully monitored and treated, may lead to shock, particularly in those with dengue haemorrhagic fever. WHO has recommended oral fluid intake of five glasses or more for adults who are suspected to have dengue fever. However, there have been no published studies looking at self-care intervention measures to improve oral fluid intake among patients suspected of dengue fever. To assess the feasibility and effectiveness of using a fluid chart to improve oral fluid intake in patients with suspected dengue fever in a primary care setting. This feasibility study used a randomized controlled study design. The data was collected over two months at a primary care clinic in a teaching hospital. The inclusion criteria were: age > 12 years, patients who were suspected to have dengue fever based on the assessment by the primary healthcare clinician, fever for > three days, and thrombocytopenia (platelets < 150 x 109/L). Both groups received a dengue home care card. The intervention group received the fluid chart and a cup (200ml). Baseline clinical and laboratory data, 24-hour fluid recall (control group), and fluid chart were collected. The main outcomes were: hospitalization rates, intravenous fluid requirement and total oral fluid intake. Among the 138 participants who were included in the final analysis, there were fewer hospital admissions in the intervention group (n = 7, 10.0%) than the control group (n = 12, 17.6%) (p = 0.192). Similarly, fewer patients (n = 9, 12.9%) in the intervention group required intravenous fluid compared to the control group (n = 15, 22.1%), (p = 0.154). There was an increase in the amount of daily oral fluid intake in the intervention group (about 3,000 ml) compared to the control group (about 2,500 ml, p = 0.521). However, these differences did not reach statistical significance. This is a feasible and acceptable study to perform in a primary care setting. The fluid chart is a simple, inexpensive tool that may reduce hospitalization and intravenous fluid requirement in suspected dengue patients. A randomized controlled trial with larger sample size is needed to determine this conclusively. International Standard Randomized Controlled Trial Number (ISRCTN) Registry ISRCTN25394628 http://www.isrctn.com/ISRCTN25394628.
High Throughput Strontium Isotope Method for Monitoring Fluid Flow Related to Geological CO2 Storage
NASA Astrophysics Data System (ADS)
Capo, R. C.; Wall, A. J.; Stewart, B. W.; Phan, T. T.; Jain, J. C.; Hakala, J. A.; Guthrie, G. D.
2012-12-01
Natural isotope tracers, such as strontium (Sr), can be a unique and powerful component of a monitoring strategy at a CO2 storage site, facilitating both the quantification of reaction progress for fluid-rock interactions and the tracking of brine migration caused by CO2 injection. Several challenges must be overcome, however, to enable the routine use of isotopic tracers, including the ability to rapidly analyze numerous aqueous samples with potentially complex chemical compositions. In a field situation, it might be necessary to analyze tens of samples over a short period of time to identify subsurface reactions and respond to unexpected fluid movement in the host formation. These conditions require streamlined Sr separation chemistry for samples ranging from pristine groundwaters to those containing high total dissolved solids, followed by rapid measurement of isotope ratios with high analytical precision. We have optimized Sr separation chemistry and MC-ICP-MS methods to provide rapid and precise measurements of isotope ratios in geologic, hydrologic, and environmental samples. These improvements will allow an operator to independently prepare samples for Sr isotope analysis off-site using fast, low cost chemical separation procedures and commercially available components. Existing vacuum-assisted Sr separation procedures were modified by using inexpensive disposable parts to eliminate cross contamination. Experimental results indicate that the modified columns provide excellent separation of Sr from chemically complex samples and that Sr can be effectively isolated from problematic matrix elements (e.g., Ca, Ba, K) associated with oilfield brines and formation waters. The separation procedure is designed for high sample throughput in which batches of 24 samples can be processed in approximately 2 hours, and are ready for Sr isotope measurements by MC-ICP-MS immediately after collection from the columns. Precise Sr isotope results can be achieved by MC-ICP-MS with a throughput of 4 to 5 samples per hour. Our mean measured value of NIST Sr isotope standard SRM 987 is 0.710265 ± 0.000014 (2σ, n = 94). A range of brines and CO2-rich fluids analyzed by this method yielded results within the analytical uncertainty of 87Sr/86Sr ratios previously determined by standard column separation and thermal ionization mass spectrometry. This method provides a fast and effective way to use Sr isotopes for monitoring purposes related to geological CO2 storage.
The use of spore strips for monitoring the sterilization of bottled fluids.
Selkon, J. B.; Sisson, P. R.; Ingham, H. R.
1979-01-01
A bacterial spore test has been developed which enables the efficacy of the sterilizing cycle recommended by the British Pharmaceutical Codex (1973) for bottled fluids to be accurately monitored. During a 14-month period this test detected faults in 3.3% of the sterilizing cycles, representing five distinct episodes of sterilization failure that passed unnoticed by the conventional controls of physical measurements and sterility testing. There were no failures of sterilization as detected by conventional techniques which were not indicated by the spore test. PMID:458140
Optofluidic two-dimensional grating volume refractive index sensor.
Sarkar, Anirban; Shivakiran Bhaktha, B N; Khastgir, Sugata Pratik
2016-09-10
We present an optofluidic reservoir with a two-dimensional grating for a lab-on-a-chip volume refractive index sensor. The observed diffraction pattern from the device resembles the analytically obtained fringe pattern. The change in the diffraction pattern has been monitored in the far-field for fluids with different refractive indices. Reliable measurements of refractive index variations, with an accuracy of 6×10-3 refractive index units, for different fluids establishes the optofluidic device as a potential on-chip tool for monitoring dynamic refractive index changes.
Corbett, James A.; Meacham, Sterling A.
1981-01-01
The fluid from a breeder nuclear reactor, which may be the sodium cooling fluid or the helium reactor-cover-gas, or the helium coolant of a gas-cooled reactor passes over the portion of the enclosure of a gaseous discharge device which is permeable to hydrogen and its isotopes. The tritium diffused into the discharge device is radioactive producing beta rays which ionize the gas (argon) in the discharge device. The tritium is monitored by measuring the ionization current produced when the sodium phase and the gas phase of the hydrogen isotopes within the enclosure are in equilibrium.
Method and Apparatus for Measuring Fluid Flow
NASA Technical Reports Server (NTRS)
Arndt, G. Dickey (Inventor); Nguyen, Thanh X. (Inventor); Carl, James R. (Inventor)
1997-01-01
Method and apparatus for making measurements on fluids related to their complex permeability are disclosed. A microwave probe is provided for exposure to the fluids. The probe can be non-intrusive or can also be positioned at the location where measurements are to be made. The impedance of the probe is determined. in part. by the complex dielectric constant of the fluids at the probe. A radio frequency signal is transmitted to the probe and the reflected signal is phase and amplitude detected at a rapid rate for the purpose of identifying the fluids. Multiple probes may be selectively positioned to monitor the behavior of the fluids including their flow rate. Fluids may be identified as between two or more different fluids as well as multiple phases of the same fluid based on differences between their complex permittivities.
[Arterial pressure curve and fluid status].
Pestel, G; Fukui, K
2009-04-01
Fluid optimization is a major contributor to improved outcome in patients. Unfortunately, anesthesiologists are often in doubt whether an additional fluid bolus will improve the hemodynamics of the patient or not as excess fluid may even jeopardize the condition. This article discusses physiological concepts of liberal versus restrictive fluid management followed by a discussion on the respective capabilities of various monitors to predict fluid responsiveness. The parameter difference in pulse pressure (dPP), derived from heart-lung interaction in mechanically ventilated patients is discussed in detail. The dPP cutoff value of 13% to predict fluid responsiveness is presented together with several assessment techniques of dPP. Finally, confounding variables on dPP measurements, such as ventilation parameters, pneumoperitoneum and use of norepinephrine are also mentioned.
Intraoperative Fluids and Fluid Management for Ambulatory Dental Sedation and General Anesthesia.
Saraghi, Mana
2015-01-01
Intravenous fluids are administered in virtually every parenteral sedation and general anesthetic. The purpose of this article is to review the physiology of body-water distribution and fluid dynamics at the vascular endothelium, evaluation of fluid status, calculation of fluid requirements, and the clinical rationale for the use of various crystalloid and colloid solutions. In the setting of elective dental outpatient procedures with minor blood loss, isotonic balanced crystalloid solutions are the fluids of choice. Colloids, on the other hand, have no use in outpatient sedation or general anesthesia for dental or minor oral surgery procedures but may have several desirable properties in long and invasive maxillofacial surgical procedures where advanced hemodynamic monitoring may assess the adequacy of intravascular volume.
Hybrid atomistic simulation of fluid uptake in a deformable solid
NASA Astrophysics Data System (ADS)
Moghadam, Mahyar M.; Rickman, J. M.
2014-01-01
Fluid imbibition via diffusion in a deformable solid results in solid stresses that may, in turn, alter subsequent fluid uptake. To examine this interplay between diffusional and elastic fields, we employed a hybrid Monte Carlo-molecular dynamics scheme to model the coupling of a fluid reservoir to a deformable solid, and then simulated the resulting fluid permeation into the solid. By monitoring the instantaneous structure factor and solid dimensions, we were able to determine the compositional strain associated with imbibition, and the diffusion coefficient in the Fickian regime was obtained from the time dependence of the fluid uptake. Finally, for large, mobile fluid atoms, a non-Fickian regime was highlighted and possible mechanisms for this behavior were identified.
Direction dependence of displacement time for two-fluid electroosmotic flow.
Lim, Chun Yee; Lam, Yee Cheong
2012-03-01
Electroosmotic flow that involves one fluid displacing another fluid is commonly encountered in various microfludic applications and experiments, for example, current monitoring technique to determine zeta potential of microchannel. There is experimentally observed anomaly in such flow, namely, the displacement time is flow direction dependent, i.e., it depends if it is a high concentration fluid displacing a low concentration fluid, or vice versa. Thus, this investigation focuses on the displacement flow of two fluids with various concentration differences. The displacement time was determined experimentally with current monitoring method. It is concluded that the time required for a high concentration solution to displace a low concentration solution is smaller than the time required for a low concentration solution to displace a high concentration solution. The percentage displacement time difference increases with increasing concentration difference and independent of the length or width of the channel and the voltage applied. Hitherto, no theoretical analysis or numerical simulation has been conducted to explain this phenomenon. A numerical model based on finite element method was developed to explain the experimental observations. Simulations showed that the velocity profile and ion distribution deviate significantly from a single fluid electroosmotic flow. The distortion of ion distribution near the electrical double layer is responsible for the displacement time difference for the two different flow directions. The trends obtained from simulations agree with the experimental findings.
Direction dependence of displacement time for two-fluid electroosmotic flow
Lim, Chun Yee; Lam, Yee Cheong
2012-01-01
Electroosmotic flow that involves one fluid displacing another fluid is commonly encountered in various microfludic applications and experiments, for example, current monitoring technique to determine zeta potential of microchannel. There is experimentally observed anomaly in such flow, namely, the displacement time is flow direction dependent, i.e., it depends if it is a high concentration fluid displacing a low concentration fluid, or vice versa. Thus, this investigation focuses on the displacement flow of two fluids with various concentration differences. The displacement time was determined experimentally with current monitoring method. It is concluded that the time required for a high concentration solution to displace a low concentration solution is smaller than the time required for a low concentration solution to displace a high concentration solution. The percentage displacement time difference increases with increasing concentration difference and independent of the length or width of the channel and the voltage applied. Hitherto, no theoretical analysis or numerical simulation has been conducted to explain this phenomenon. A numerical model based on finite element method was developed to explain the experimental observations. Simulations showed that the velocity profile and ion distribution deviate significantly from a single fluid electroosmotic flow. The distortion of ion distribution near the electrical double layer is responsible for the displacement time difference for the two different flow directions. The trends obtained from simulations agree with the experimental findings. PMID:22662083
NASA Astrophysics Data System (ADS)
Dent, Paul; Tun, Sai Han; Fillioe, Seth; Deng, Bin; Satalin, Josh; Nieman, Gary; Wilcox, Kailyn; Searles, Quinn; Narsipur, Sri; Peterson, Charles M.; Goodisman, Jerry; Mostrom, James; Steinmann, Richard; Chaiken, J.
2018-02-01
We previously reported a new algorithm "PV[O]H" for continuous, noninvasive, in vivo monitoring of hematocrit changes in blood and have since shown its utility for monitoring in humans during 1) hemodialysis, 2) orthostatic perturbations and 3) during blood loss and fluid replacement in a rat model. We now show that the algorithm is sensitive to changes in hemoglobin oxygen saturation. We document the phenomenology of the effect and explain the effect using new results obtained from humans and rat models. The oxygen sensitivity derives from the differential absorption of autofluorescence originating in the static tissues by oxy and deoxy hemoglobin. Using this approach we show how to perform simultaneous, noninvasive, in vivo, continuous monitoring of hematocrit, vascular volume, hemoglobin oxygen saturation, pulse rate and breathing rate in mammals using a single light source. We suspect that monitoring of changes in this suite of vital signs can be provided with improved time response, sensitivity and precision compared to existing methodologies. Initial results also offer a more detailed glimpse into the systemic oxygen transport in the circulatory system of humans.
NASA Astrophysics Data System (ADS)
Syverson, D.; Seyfried, W. E.
2010-12-01
Anhydrite (CaSO4) is an important mineral in subseafloor hydrothermal systems. Its solubility likely plays a role in controlling mass transfer reactions in the relatively low temperature and ultramafic-hosted Lost City Hydrothermal Field (LCHF), while also precipitating from seawater during recharge of more widespread high-temperature hydrothermal systems at mid-ocean ridges. Strontium partitions into anhydrite, although the magnitude and mechanism by which this occurs, is still unclear, as is the effect of precipitation rate. In the absence of these data it is not possible to predict accurately the geochemical implications of Sr/Ca ratios of vent fluids. Accordingly, the potential usefulness of these data to constrain temperature, and as a means to understand the flux of seawater derived Sr into deeper portions of subseafloor hydrothermal systems, is limited. Here we report results of experiments designed to assess Ca-Sr exchange during anhydrite-fluid reaction as a function of temperature, fluid chemistry and distance from equilibrium. Anhydrite used for the experiments was synthesized to avoid compositional impurities and annealed to achieve grain sizes (10-100 micron) and uniform crystalline properties. NaCl fluids (0.55 m) with known Sr/Ca ratios were used for the experiments. Experiments were performed at 200° and 250°C, 500 bars, while time series changes in fluid chemistry were monitored by fluid sampling at experimental conditions. Isobaric temperature change as well as chemical perturbation by addition of fluids with anomalous Sr/Ca ratio permitted phase equilibria to be unambiguously assed. Moreover, the chemical perturbation experiments provided information on the effect of rate of reaction on Sr-Ca exchange. Isobaric temperature jumps demonstrate that initially anhydrite precipitation incorporates Sr preferentially. With further reaction progress and approach to equilibrium Sr uptake by anhydrite recrystallization becomes less effective. Long-term equilibration (~3 months) of fluid and anhydrite at 250°C produces aSr/aCa*1000 of 2.8425. Results from the isothermal spike experiments indicate that the rate of exchange (dF/dt) for aSr/aCa is on the order of 0.01/day. Applying the experimentally determined Sr/Ca data to endmember vent fluids from LCHF suggests subseafloor temperatures near 200°C, in good agreement with constraints imposed by observed Ca and sulfate concentrations assuming anhydrite-fluid equilibria. Furthermore, the effect of supersaturated partitioning and experimentally determined rate at which Sr is incorporated into anhydrite suggests that seawater Sr uptake by anhydrite may be very effective, especially if the rate of formation is rapid, as might be expected owing to the sharply increasing geothermal gradient likely for the recharge portions of most of basalt-hosted hydrothermal systems at mid-ocean ridges. This would have important implications for the flux of radiogenic Sr and calculations of fluid/rock ratios at depth in the ocean crust.
Inter-device differences in monitoring for goal-directed fluid therapy.
Thiele, Robert H; Bartels, Karsten; Gan, Tong-Joo
2015-02-01
Goal-directed fluid therapy is an integral component of many Enhanced Recovery After Surgery (ERAS) protocols currently in use. The perioperative clinician is faced with a myriad of devices promising to deliver relevant physiologic data to better guide fluid therapy. The goal of this review is to provide concise information to enable the clinician to make an informed decision when choosing a device to guide goal-directed fluid therapy. The focus of many devices used for advanced hemodynamic monitoring is on providing measurements of cardiac output, while other, more recent, devices include estimates of fluid responsiveness based on dynamic indices that better predict an individual's response to a fluid bolus. Currently available technologies include the pulmonary artery catheter, esophageal Doppler, arterial waveform analysis, photoplethysmography, venous oxygen saturation, as well as bioimpedance and bioreactance. The underlying mechanistic principles for each device are presented as well as their performance in clinical trials relevant for goal-directed therapy in ERAS. The ERAS protocols typically involve a multipronged regimen to facilitate early recovery after surgery. Optimizing perioperative fluid therapy is a key component of these efforts. While no technology is without limitations, the majority of the currently available literature suggests esophageal Doppler and arterial waveform analysis to be the most desirable choices to guide fluid administration. Their performance is dependent, in part, on the interpretation of dynamic changes resulting from intrathoracic pressure fluctuations encountered during mechanical ventilation. Evolving practice patterns, such as low tidal volume ventilation as well as the necessity to guide fluid therapy in spontaneously breathing patients, will require further investigation.
Ultrasonic Apparatus and Technique to Measure Changes in Intracranial Pressure
NASA Technical Reports Server (NTRS)
Yost, William T. (Inventor); Cantrell, John H. (Inventor)
2002-01-01
Changes in intracranial pressure can be measured dynamically and non-invasively by monitoring one or more cerebrospinal fluid pulsatile components. Pulsatile components such as systolic and diastolic blood pressures are partially transferred to the cerebrospinal fluid by way of blood vessels contained in the surrounding brain tissue and membrane. As intracranial pressure varies these cerebrospinal fluid pulsatile components also vary. Thus, intracranial pressure can be dynamically measured. Furthermore, use of acoustics allows the measurement to be completely non-invasive. In the preferred embodiment, phase comparison of a reflected acoustic signal to a reference signal using a constant frequency pulsed phase-locked-loop ultrasonic device allows the pulsatile components to be monitored. Calibrating the device by inducing a known change in intracranial pressure allows conversion to changes in intracranial pressure.
Pandey, Sajan; Jin, Yi; Gao, Liang; Zhou, Cheng Cheng; Cui, Da Ming
2017-03-01
Negative-pressure hydrocephalus (NegPH), a very rare condition of unknown etiology and optimal treatment, usually presents postneurosurgery with clinical and imaging features of hydrocephalus, but with negative cerebrospinal fluid pressure. We describe a NegPH case of -3 mm Hg intracranial pressure that was successfully treated to achieve 5 mm Hg under continuous intracranial pressure monitoring with horizontal positioning, head down and legs elevated to 10°-15°, neck wrapping for controlled venous drainage, chest and abdomen bandages, infusion of 5% dextrose fluid to lower plasma osmolarity (Na + , 130-135 mmol/L), daily cerebrospinal fluid drainage >200 mL, and arterial blood gas partial pressure of carbon dioxide >40 mm Hg. Copyright © 2016 Elsevier Inc. All rights reserved.
Strain - The Heart of the Matter
NASA Technical Reports Server (NTRS)
Gapinski, Wendy R.
2013-01-01
Objective: Identify how much exercise is needed to maintain pre-bedrest / pre-spaceflight strength, minimize any flight complications and reduce time required to reacclimate to Earth's gravity. Subjects volunteered to participate in a 70 day 6deg head down tilt (HDT) study at UTMB hospital in Galveston. HDT are used to study microgravity for several reasons: 1. Allows subjects to experience atrophy of lower extremities from disuse. 2. Allows scientist to study the fluid shifts and the subject's cardiovascular and physiological effects. 3. Allows several studies to be measured and conducted simultaneously in a safe and monitored environment. Throughout those 10 weeks, subjects were either in an exercise or control group. Never before has cardiac strain been monitored at set time points throughout spaceflight or bed rest study. Once we clearly understand this technique, protocols can be formulated for astronauts to use on the ISS as both a diagnostic and monitoring tool. Echoes could have the possibility to predict & monitor heart health, cardiac strength, endurance, and overall rate of muscle degradation. Also, echoes can act as an additional factor in determining exercise prescriptions and effectiveness.
Li, Jingwen; Qu, Hang; Skorobogatiy, Maksim
2015-09-07
We demonstrate simultaneous monitoring of the real and imaginary parts of the liquid analyte refractive index by using a hollow-core Bragg fiber. We apply this two-channel fiber sensor to monitor concentrations of various commercial cooling oils. The sensor operates using spectral monitoring of the fiber bandgap center wavelength, as well as monitoring of the fiber transmission amplitude at mid-bandgap position. The sensitivity of the fiber sensor to changes in the real part of the core refractive index is found to be 1460nm/Refractive index unit (RIU). By using spectral modality and effective medium theory, we determine the concentrations of the two commercial fluids from the measured refractive indices with an accuracy of ~0.57% for both low- and high-loss oils. Moreover, using an amplitude-based detection modality allows determination of the oil concentration with accuracy of ~1.64% for low-loss oils and ~2.81% for the high-loss oils.
Vosloo, W; Morris, J; Davis, A; Giles, M; Wang, J; Nguyen, H T T; Kim, P V; Quach, N V; Le, P T T; Nguyen, P H N; Dang, H; Tran, H X; Vu, P P; Hung, V V; Le, Q T; Tran, T M; Mai, T M T; Le, Q T V; Singanallur, N B
2015-10-01
In high-density farming practices, it is important to constantly monitor for infectious diseases, especially diseases that have the potential to spread rapidly between holdings. Pigs are known to amplify foot-and-mouth disease (FMD) by excreting large amounts of virus, and it is therefore important to detect the virus quickly and accurately to minimize the spread of disease. Ropes were used to collect oral fluid samples from pigs, and each sample was compared to saliva samples collected from individual animals by detecting FMD virus RNA using real-time PCR. Two different experiments are described where groups of pigs were infected with different serotypes of FMD virus, either with or without vaccination, and unvaccinated pigs were kept in aerosol contact. The sensitivity of the rope sampling varied between 0.67 and 0.92, and the statistical agreement between this method and individual sampling ranged from substantial to moderate for the two different serotypes. The ease of collecting oral fluids using ropes together with the high sensitivity of subsequent FMD detection through PCR indicates that this could be a useful method to monitor pig populations for FMD virus infection. With further validation of the sensitivity of detection of FMD virus RNA, this can be a cost-effective, non-invasive diagnostic tool. © 2013 Blackwell Verlag GmbH.
Area Monitoring for Detection of Leaks and/or Flames
NASA Technical Reports Server (NTRS)
Mian, Zahid F. (Inventor); Gamache, Ronald W. (Inventor); Glasser, Nick (Inventor)
2015-01-01
A solution for monitoring an area for the presence of a flame and/or a leak, such as from a pressurized fluid, is provided. An imaging device can be used that acquires image data based on electromagnetic radiation having wavelengths only corresponding to at least one region of the electromagnetic spectrum in which electromagnetic radiation from an ambient light source is less than the electromagnetic radiation emitted by at least one type of flame for which the presence within the area is being monitored. An acoustic device can be used that is configured to acquire acoustic data for the area and enhance acoustic signals in a range of frequencies corresponding to a leak of a pressurized fluid present in the area.
Area Monitoring for Detection of Leaks And/Or Flames
NASA Technical Reports Server (NTRS)
Mian, Zahid F. (Inventor); Gamache, Ronald W. (Inventor); Glasser, Nicholas (Inventor)
2017-01-01
A solution for monitoring an area for the presence of a flame and/or a leak, such as from a pressurized fluid, is provided. An imaging device can be used that acquires image data based on electromagnetic radiation having wavelengths only corresponding to at least one region of the electromagnetic spectrum in which electromagnetic radiation from an ambient light source is less than the electromagnetic radiation emitted by at least one type of flame for which the presence within the area is being monitored. An acoustic device can be used that is configured to acquire acoustic data for the area and enhance acoustic signals in a range of frequencies corresponding to a leak of a pressurized fluid present in the area.
Parada, M A; Puig de Parada, M; Hernandez, L; Hoebel, B G
1995-08-01
A low-torque, bubble-free and multiple-channel fluid swivel of easy construction was recently described. This paper describes the design, construction and testing of 3 electrical channels added to the original fluid swivel. The new channels were tested monitoring intrahypothalamic temperature (T(hy)) by means of a copper-constantan thermocouple in freely moving rats, before and after a single intraperitoneal (i.p.) amphetamine injection (3 mg/kg). This test showed an increase in T(hy) after the injection and the maintenance of the electrical continuity along the whole testing period, even when the animals were hyperactive. With this improvement the original swivel was transformed in a more versatile device for experiments requiring fluid handlings and electrophysiological manipulations. Electrical stimulation as in kindling or brain self-stimulation, and electrophysiological recordings as in electroencephalography, electromiography, electrocardiography, in vivo voltammetry and even neuronal unit recording, are just examples of the electrophysiological methods that can be combined with drug self-administration and microdialysis using the present device.
On-line monitoring of fluid bed granulation by photometric imaging.
Soppela, Ira; Antikainen, Osmo; Sandler, Niklas; Yliruusi, Jouko
2014-11-01
This paper introduces and discusses a photometric surface imaging approach for on-line monitoring of fluid bed granulation. Five granule batches consisting of paracetamol and varying amounts of lactose and microcrystalline cellulose were manufactured with an instrumented fluid bed granulator. Photometric images and NIR spectra were continuously captured on-line and particle size information was extracted from them. Also key process parameters were recorded. The images provided direct real-time information on the growth, attrition and packing behaviour of the batches. Moreover, decreasing image brightness in the drying phase was found to indicate granule drying. The changes observed in the image data were also linked to the moisture and temperature profiles of the processes. Combined with complementary process analytical tools, photometric imaging opens up possibilities for improved real-time evaluation fluid bed granulation. Furthermore, images can give valuable insight into the behaviour of excipients or formulations during product development. Copyright © 2014 Elsevier B.V. All rights reserved.
Olechno, Joseph; Ellson, Richard; Browning, Brent; Stearns, Richard; Mutz, Mitchell; Travis, Michael; Qureshi, Shehrzad; Shieh, Jean
2005-08-01
Acoustic auditing is a non-destructive, non-invasive technique to monitor the composition and volume of fluids in open or sealed microplates and storage tubes. When acoustic energy encounters an interface between two materials, some of the energy passes through the interface, while the remainder is reflected. Acoustic energy applied to the bottom of a multi-well plate or a storage tube is reflected by the fluid contents of the microplate or tube. The amplitude of these reflections or echoes correlates directly with properties of the fluid, including the speed of sound and the concentration of water in the fluid. Once the speed of sound in the solution is known from the analysis of these echoes, it is easy to determine the depth of liquid and, thereby, the volume by monitoring how long it takes for sound energy to reflect off the fluid meniscus. This technique is rapid (>100,000 samples per day), precise (<1% coefficient of variation for hydration measurements, <4% coefficient of variation for volume measurements), and robust. It does not require uncapping tubes or unsealing or unlidding microplates. The sound energy is extremely gentle and has no deleterious impact upon the fluid or compounds dissolved in it.
Effect of the Hydrothermal Fluid Composition on the Serpentinization of Olivine and Pyroxene
NASA Astrophysics Data System (ADS)
Daniel, I.; Andreani, M.
2016-12-01
The hydrothermal alteration of ultramafic rocks leads to the serpentinization reaction that mainly forms serpentine and variable amounts of talc, brucite and magnetite, as well as hydrogen and magnesite when carbonate is present in the fluid. The serpentinization kinetics of pyroxene under hydrothermal conditions has been very little studied in comparison with olivine, and both have been evaluated experimentally only in simple aqueous fluids. Here, we have evaluated the effect of the fluid chemistry - aluminum, carbonate and pH on the serpentinization rate of olivine and orthopyroxene at 200 °C, 340 °C and 200 MPa to simulate natural hydrothermal conditions. We used low-pressure diamond-anvil cells (lp-DAC) and time-resolved X-ray diffraction to monitor in situ the progress of serpentinization in twelve experiments. We also performed several complementary long-lasting experiments of several days in particular with orthopyroxene, for which in situ monitoring was not possible. At 340 °C in presence of Al and/or carbonate and at high pH, olivine conversion into lizardite is extremely fast with a half-time reaction t1/2 = 2 hrs only, while orthopyroxene did not react much even after 6 days (11%). In contrast to olivine, orthopyroxene conversion to serpentine was faster without Al (48 % in 6 days). Magnetite was also observed to form in the runs with olivine at 340 °C and moderate pH. In experiments run with orthopyroxene only, we observed the exclusive formation of proto-serpentine instead of lizardite. We propose that the contrasted effect of Al on the serpentinization rate of olivine and orthopyroxene results from the complexation of Al in the solution that reacts differently with the mineral surfaces during their dissolution. The positively charged olivine surface allows the adsorption of the dominant negatively charged Al(OH)4- complex, while the neutral surface of orthopyroxene does not. This adsorption process could facilitate both the dissolution of olivine and the fast nucleation-growth of an Al-enriched lizardite. The detailed and relative role of pH and carbonate on the serpentinization of olivine will also be discussed.
NASA Astrophysics Data System (ADS)
Simon, H.; Buske, S.
2017-12-01
The Eger Rift zone (Czech Republic) is a intra-continental non-volcanic region and is characterized by outstanding geodynamic activities, which result in earthquake swarms and significant CO2 emanations. Because fluid-induced stress can trigger earthquake swarms, both natural phenomena are probably related to each other. The epicentres of the earthquake swarms cluster at the northern edge of the Cheb Basin. Although the location of the cluster coincides with the major Mariánské-Lázně Fault Zone (MLFZ) the strike of the focal plane indicates another fault zone, the N-S trending Počátky-Plesná Zone (PPZ). Isotopic analysis of the CO2-rich fluids revealed a significant portion of upper mantle derived components, hence a magmatic fluid source in the upper mantle was postulated. Because of these phenomena, the Eger Rift area is a unique site for interdisciplinary drilling programs to study the fluid-earthquake interaction. The ICDP project PIER (Probing of Intra-continental magmatic activity: drilling the Eger Rift) will set up an observatory, consisting of five monitoring boreholes. In preparation for the drilling, the goal of the seismic survey is the characterization of the projected fluid-monitoring drill site at the CO2 degassing mofette field near Hartoušov. This will be achieved by a 6 km long profile with dense source and receiver spacing. The W-E trending profile will cross the proposed drill site and the surface traces of MLFZ and PPZ. The outcome of the seismic survey will be a high-resolution structural image of potential reflectors related to these fault zones. This will be achieved by the application of advanced pre-stack depth migration methods and a detailed P-wave velocity distribution of the area obtained from first arrival tomography. During interpretation of the seismic data, a geoelectrical resistivity model, acquired along the same profile line, will provide important constraints, especially with respect to fluid pathways.
Nguyen, Duc Hai; Richard, Louis; Burchard, Javier F
2005-02-01
An exposure chamber was designed to study the effects of electric and magnetic fields (EMF) on oestrous cycles, hormonal profile during gestation, pineal function, quantity and quality of milk production, feed intake, and central nervous system of dairy cattle. The chamber was 15 x 10 x 3 m; and the control system was fully computerized so that the field intensities can be varied and monitored continuously, on site or remotely. During exposure to EMF, milk production, feed consumption, and health were monitored closely and blood and cerebral spinal fluid were continuously sampled. The chamber characteristics allow use of a wide range of exposure such as electric fields (0-30 kV/m) and magnetic fields (0-100 microT) at frequencies ranging from 45 to 3000 Hz.
Flow Coupling between a Rotor and a Stator in Turbomachinery
1990-04-01
potential-flow effects which would occur if the working fluid were perfectly inviscid. All observations made in practical situations represent a combination...interest. They are primarily working papers intended for internal use. They carry an identifying number which indicates their type and the numerical code of...release; distribution is unlimited. 4. PERFORMING ORGANIZATION REPORT NUMBER(S) s. MONITORING ORGANIZATION REPORT NUMBER(S) DTRC-PAS-90/15 Si. NAME OF
Implantable device for in-vivo intracranial and cerebrospinal fluid pressure monitoring
Ericson, Milton N.; McKnight, Timothy E.; Smith, Stephen F.; Hylton, James O.
2003-01-01
The present invention relates to a completely implantable intracranial pressure monitor, which can couple to existing fluid shunting systems as well as other internal monitoring probes. The implant sensor produces an analog data signal which is then converted electronically to a digital pulse by generation of a spreading code signal and then transmitted to a location outside the patient by a radio-frequency transmitter to an external receiver. The implanted device can receive power from an internal source as well as an inductive external source. Remote control of the implant is also provided by a control receiver which passes commands from an external source to the implant system logic. Alarm parameters can be programmed into the device which are capable of producing an audible or visual alarm signal. The utility of the monitor can be greatly expanded by using multiple pressure sensors simultaneously or by combining sensors of various physiological types.
Experimental Evidence of Volcanic Earthquakes Induced by Different Fluid Types
NASA Astrophysics Data System (ADS)
Clarke, J. A.; Adam, L.; Sarout, J.; van Wijk, K.; Dautriat, J. D.; Kennedy, B.
2017-12-01
Low Frequency volcanic seismicity has long been associated with resonance in fluid-filled cracks or conduits driven by pressure perturbations at depth. In volcano monitoring, fluid movement, fracturing and the conduit geometry are interpreted based on field observations, laboratory experiments, and numerical models. Fluids in a volcanic environment include gasses, brine and magmas with different viscosities. Magma viscosity is a key influence on eruptive behaviour. For example, increasing magma viscosity is known to favour explosive eruptions. How different fluids affect volcano seismicity is not well understood. Here, we explore the effects of fluid type on volcano seismic signals. Frequency content in the signal, frequency of the events, source mechanism and quality factor are studied. We simulate volcano tectonic (fracturing) and volcano seismic (fluid movement) signatures in a controlled laboratory environment using a range of rock samples, fluid types and pressure conditions. The viscosity of the fluids spans six orders of magnitude, representing realistic volcanic fluids. Microseismicity is generated by venting pressurised fluids through pre-generated fracture networks in cylindrical rock core samples and detected by an array of 18 ultrasonic transducers. We fracture samples of two lithologies: 1) low porosity impermeable granite samples and 2) a permeable volcanic ash tuff sample. Permeability and porosity in the granites are due to a fracture network, while in the tuff a high porosity matrix ( 40 %) and a fracture network interact. The fluids used are nitrogen gas, water, and mixtures of water and glycerol. We generate and detect a myriad of seismic event types, some of which resemble well-known families of volcano-tectonic, low-frequency, hybrid and tremor-type seismicity. Samples with fluids of lower density and viscosity generate a higher number of seismic events. We will present an integrated analysis of the event types, frequency content, source locations and mechanisms. In addition, we explore the importance of seismic wave attenuation by studying the relationship between wave path and event frequency content.
NASA Astrophysics Data System (ADS)
Cigolini, Corrado; Laiolo, Marco; Coppola, Diego
2017-04-01
The behavior of fluids in hydrothermal systems is critical in volcano monitoring and geothermal prospecting. Analyzing the time series of radon emissions on active volcanoes is strategic for detecting and interpreting precursory signals of changes in volcanic activity, eventually leading to eruptions. Radon is a radioactive gas generated from the decay of U bearing rocks, soils and magmas. Although radon has been regarded as a potential precursor of earthquakes, radon anomalies appear to be better suited to forecast volcanic eruptions since we know where paroxysms may occur and we can follow the evolution of volcanic activity. Radon mapping at active volcanoes is also a reliable tool to assess diffuse and concentrated degassing as well as efficiently detecting earthquake-volcano interactions. Systematic radon monitoring has been shown to be a key factor for evaluating the rise of volcanic and hydrothermal fluids. In fact, the decay properties of radon, the duration of radon anomalies together with sampling rates may be cross-checked with the chemistry of hydrothermal fluids (and their transport properties) to constrain fluids ascent rates and to infer the permeability and porosity of rocks in sectors surrounding the active conduits. We hereby further discuss the data of radon surveys and monitoring at Somma-Vesuvius, Stromboli and La Soufrière (Guadeloupe, Lesser Antilles). The integrated analysis of seismic and geochemical data, including radon emissions, may be successfully used in testing temperature distributions and variations of porosity and permeability in volcanic hydrothermal systems and can be used as a proxy to analyze geothermal reservoirs.
Crystal Growth of ZnSe and Related Ternary Compound Semiconductors by Vapor Transport
NASA Technical Reports Server (NTRS)
2003-01-01
The objective of the project is to determine the relative contributions of gravity-driven fluid flows to the compositional distribution, incorporation of impurities and defects, and deviation from stoichiometry observed in the crystals grown by vapor transport as results of buoyancy-driven convection and growth interface fluctuations caused by irregular fluid-flows. ZnSe and related ternary compounds, such as ZnSeS and ZnSeTe, were grown by vapor transport technique with real time in situ non-invasive monitoring techniques. The grown crystals were characterized extensively to correlate the grown crystal properties with the growth conditions. Significant effects of gravity vector orientation on the growth crystal morphology and point defect distribution were observed.
NASA Astrophysics Data System (ADS)
Mitrofanova, O. V.; Ivlev, O. A.; Pozdeeva, I. G.; Urtenov, D. S.
2017-11-01
The results of studies are aimed at developing theoretical foundations and instrumentation system to ensure a technology of vortex diagnostics of the state of flows of fluids for nuclear power installations with power water reactors and fast neutrons reactors with liquid-metal coolants. The technology of vortex diagnostics is based on the study of acoustic, magneto-hydrodynamic and resonant effects related to the formation of stable vortex structures. For creation a system of monitoring and diagnostics of the crisis phenomena due to hydrodynamics of the flow, it is proposed to use acoustic method to record the radiation of elastic waves in the fluids caused by the dynamic local rearrangement of its structure.
NASA Astrophysics Data System (ADS)
Khan, Kashif Ali; Butt, Asma Rashid; Raza, Nauman
2018-03-01
In this study, an endeavor is to observe the unsteady two-dimensional boundary layer flow with heat and mass transfer behavior of Casson fluid past a stretching sheet in presence of wall mass transfer by ignoring the effects of viscous dissipation. Chemical reaction of linear order is also invoked here. Similarity transformation have been applied to reduce the governing equations of momentum, energy and mass into non-linear ordinary differential equations; then Homotopy analysis method (HAM) is applied to solve these equations. Numerical work is done carefully with a well-known software MATHEMATICA for the examination of non-dimensional velocity, temperature, and concentration profiles, and then results are presented graphically. The skin friction (viscous drag), local Nusselt number (rate of heat transfer) and Sherwood number (rate of mass transfer) are discussed and presented in tabular form for several factors which are monitoring the flow model.
Vibration energy harvesting in a small channel fluid flow using piezoelectric transducer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hassan, Md. Mehedi, E-mail: buetmehedi10@gmail.com; Hossain, Md. Yeam, E-mail: yeamhossain@gmail.com; Mazumder, Rakib, E-mail: rakibmazumder46075@gmail.com
2016-07-12
This work is aimed at developing a way to harvest energy from a fluid stream with the application of piezoelectric transducers in a small channel. In this COMSOL Multiphysics based simulation study, it is attempted to harvest energy from the abundant renewable source of energy available in the form of kinetic energy of naturally occurring flow of fluids. The strategy involves harnessing energy from a fluid-actuator through generation of couples, eddies and vortices, resulting from the stagnation and separation of flow around a semi-circular bluff-body attached to a cantilever beam containing a piezoceramic layer. Fluctuation of fluidic pressure impulse onmore » the beam due to vortex shedding and varying lift forces causes the flexible cantilever beam to oscillate in the direction normal to the fluid flow in a periodic manner. The periodic application and release of a mechanical strain upon the beam effected a generation of electric potential within the piezoelectric layer, thus enabling extraction of electrical energy from the kinetic energy of the fluid. The piezoelectric material properties and transducer design are kept unchanged throughout the study, whereas the configuration is tested with different fluids and varying flow characteristics. The size and geometry of the obstructing entity are systematically varied to closely inspect the output from different iterations and for finding the optimum design parameters. The intermittent changes in the generated forces and subsequent variation in the strain on the beam are also monitored to find definitive relationship with the electrical energy output.« less
Fluid Therapy in Lung Disease.
Rozanski, Elizabeth; Lynch, Alex
2017-03-01
Fluid therapy is the cornerstone of supportive care in veterinary medicine. In dogs and cats with preexisting confirmed or suspected pulmonary disease, concerns may exist that the fluid therapy may impair gas exchange, either through increases in hydrostatic pressures or extravasation. Colloidal therapy is more likely to magnify lung injury compared with isotonic crystalloids. Radiographic evidence of fluid overload is a late-stage finding, whereas point-of-care ultrasound may provide earlier information that can also be assessed periodically at the patient side. Cases should be evaluated individually, but generally a conservative fluid therapy plan is preferred with close monitoring of its tolerance. Copyright © 2016 Elsevier Inc. All rights reserved.
Instability patterns in a miscible core annular flow
NASA Astrophysics Data System (ADS)
D'Olce, Marguerite; Martin, Jerome; Rakotomalala, Nicole; Salin, Dominique; Talon, Laurent
2006-11-01
Laboratoire FAST, batiment 502, campus universitaire, 91405 Orsay Cedex (France). Experiments are performed with two miscible fluids of equal density but different viscosities. The fluids are injected co-currently and concentrically into a cylindrical pipe. The so-obtained base state is an axisymmetric parallel flow, for which the ratio of the flow rates of the two fluids monitors the relative amount (and so the radius) of the fluids. Depending on this relative amount and on the total flow rate of the fluids, unstable axisymmetric patterns such as mushrooms and pearls are observed. We delineate the diagram of occurrence of the two patterns and characterize the instabilities.
Continuous TDEM for monitoring shale hydraulic fracturing
NASA Astrophysics Data System (ADS)
Yan, Liang-Jun; Chen, Xiao-Xiong; Tang, Hao; Xie, Xing-Bing; Zhou, Lei; Hu, Wen-Bao; Wang, Zhong-Xin
2018-03-01
Monitoring and delineating the spatial distribution of shale fracturing is fundamentally important to shale gas production. Standard monitoring methods, such as time-lapse seismic, cross-well seismic and micro-seismic methods, are expensive, timeconsuming, and do not show the changes in the formation with time. The resistivities of hydraulic fracturing fluid and reservoir rocks were measured. The results suggest that the injection fluid and consequently the injected reservoir are characterized by very low resistivity and high chargeability. This allows using of the controlled-source electromagnetic method (CSEM) to monitor shale gas hydraulic fracturing. Based on the geoelectrical model which was proposed according to the well-log and seismic data in the test area the change rule of the reacted electrical field was studied to account for the change of shale resistivity, and then the normalized residual resistivity method for time lapse processing was given. The time-domain electromagnetic method (TDEM) was used to continuously monitor the shale gas fracturing at the Fulin shale gas field in southern China. A high-power transmitter and multi-channel transient electromagnetic receiver array were adopted. 9 h time series of Ex component of 224 sites which were laid out on the surface and over three fracturing stages of a horizontal well at 2800 m depth was recorded. After data processing and calculation of the normalized resistivity residuals, the changes in the Ex signal were determined and a dynamic 3D image of the change in resistivity was constructed. This allows modeling the spatial distribution of the fracturing fluid. The model results suggest that TDEM is promising for monitoring hydraulic fracturing of shale.
Tran, Bao Quoc; Miller, Philip R; Taylor, Robert M; Boyd, Gabrielle; Mach, Phillip M; Rosenzweig, C Nicole; Baca, Justin T; Polsky, Ronen; Glaros, Trevor
2018-01-05
As wearable fitness devices have gained commercial acceptance, interest in real-time monitoring of an individual's physiological status using noninvasive techniques has grown. Microneedles have been proposed as a minimally invasive technique for sampling the dermal interstitial fluid (ISF) for clinical monitoring and diagnosis, but little is known about its composition. In this study, a novel microneedle array was used to collect dermal ISF from three healthy human donors and compared with matching serum and plasma samples. Using a shotgun quantitative proteomic approach, 407 proteins were quantified with at least one unique peptide, and of those, 135 proteins were differently expressed at least 2-fold. Collectively, these proteins tended to originate from the cytoplasm, membrane bound vesicles, and extracellular vesicular exosomes. Proteomic analysis confirmed previously published work that indicates that ISF is highly similar to both plasma and serum. In this study, less than one percent of proteins were uniquely identified in ISF. Taken together, ISF could serve as a minimally invasive alternative for blood-derived fluids with potential for real-time monitoring applications.
NASA Astrophysics Data System (ADS)
Nowak, Martin; van Geldern, Robert; Myrttinen, Anssi; Veith, Becker; Zimmer, Martin; Barth, Johannes
2013-04-01
With rising atmospheric greenhouse gas concentrations, CCS technologies are a feasible option to diminish consequences of uncontrolled anthropogenic CO2 emissions and related climate change. However, application of CCS technologies requires appropriate and routine monitoring tools in order to ensure a safe and effective CO2 injection. Stable isotope techniques have proven as a useful geochemical monitoring tool at several CCS pilot projects worldwide. They can provide important information about gas - water - rock interactions, mass balances and CO2 migration in the reservoir and may serve as a tool to detect CO2 leakage in the subsurface and surface. Since the beginning of injection in 2008 at the Ketzin pilot site in Germany, more than 450 samples of fluids and gases have been analysed for their carbon and oxygen isotopic composition. Analytical advancements were achieved by modifying a conventional isotope ratio mass-spectrometer with a He dilution system. This allowed analyses of a larger number of CO2 gas samples from the injection well and observation wells. With this, a high-resolution monitoring program was established over a time period of one year. Results revealed that two isotopical distinct kinds of CO2 are injected at the Ketzin pilot site. The most commonly injected CO2 is so-called 'technical' CO2 with an average carbon isotopic value of about -31 ‰. Sporadically, natural source CO2 with an average δ13C value of -3 ‰ was injected. The injection of natural source CO2 generated a distinct isotope signal at the injection well that can be used as an ideal tracer. CO2 isotope values analysed at the observation wells indicate a highly dispersive migration of the supercritical CO2 that results in mixing of the two kinds of CO2 within the reservoir. Above-reservoir monitoring includes the first overlying aquifer above the cap rock. An observation well within this zone comprises an U-tube sampling device that allows frequent sampling of unaltered brine. The fluids were analysed among others for their carbon isotopic compositions of dissolved inorganic carbon (DIC). δ13CDIC values allowed to assess impacts of the carbonate-based drilling fluid during well development and helped to monitor successive geochemical re-equilibration processes of the brine. Based on the determined δ13C baseline values of the aquifer fluid, first concepts indicate the scale of change of the δ13CDIC values that would be necessary to detect CO2 leakage from the underlying storage reservoir. Recent efforts aim at applications of new laser-based isotope sensors that allow online measurements in the field. These devices are applied for CO2 gas tracer experiments as well as for monitoring of isotope composition of soil gases in the vicinity of the pilot site. This new development will allow much better temporal and spatial resolution of measurements at a lower price. Therefore, stable isotope analyses can become a strong and promising tool for subsurface as well as surface monitoring at future CCS sites.
Lattice Boltzmann modeling to explain volcano acoustic source.
Brogi, Federico; Ripepe, Maurizio; Bonadonna, Costanza
2018-06-22
Acoustic pressure is largely used to monitor explosive activity at volcanoes and has become one of the most promising technique to monitor volcanoes also at large scale. However, no clear relation between the fluid dynamics of explosive eruptions and the associated acoustic signals has yet been defined. Linear acoustic has been applied to derive source parameters in the case of strong explosive eruptions which are well-known to be driven by large overpressure of the magmatic fluids. Asymmetric acoustic waveforms are generally considered as the evidence for supersonic explosive dynamics also for small explosive regimes. We have used Lattice-Boltzmann modeling of the eruptive fluid dynamics to analyse the acoustic wavefield produced by different flow regimes. We demonstrate that acoustic waveform well reproduces the flow dynamics of a subsonic fluid injection related to discrete explosive events. Different volumetric flow rate, at low-Mach regimes, can explain both the observed symmetric and asymmetric waveform. Hence, asymmetric waveforms are not necessarily related to the shock/supersonic fluid dynamics of the source. As a result, we highlight an ambiguity in the general interpretation of volcano acoustic signals for the retrieval of key eruption source parameters, necessary for a reliable volcanic hazard assessment.
Li, Qi; Song, Ranran; Shi, Hui; Ma, Jianli; Liu, Xuehao; Li, Xiaochun
2018-04-01
The CO 2 injected into deep formations during implementation of carbon dioxide (CO 2 ) capture and storage (CCS) technology may leak and migrate into shallow aquifers or ground surfaces through a variety of pathways over a long period. The leaked CO 2 can threaten shallow environments as well as human health. Therefore, almost all monitoring programs for CCS projects around the world contain near-surface monitoring. This paper presents a U-tube based near-surface monitoring technology focusing on its first application in the Shenhua CCS demonstration project, located in the Ordos Basin, Inner Mongolia, China. First, background information on the site monitoring program of the Shenhua CCS demonstration project was provided. Then, the principle of fluid sampling and the monitoring methods were summarized for the U-tube sampler system, and the monitoring data were analyzed in detail. The U-tube based monitoring results showed that the U-tube sampler system is accurate, flexible, and representative of the subsurface fluid sampling process. The monitoring indicators for the subsurface water and soil gas at the Shenhua CCS site indicate good stratification characteristics. The concentration level of each monitoring indicator decreases with increasing depth. Finally, the significance of this near-surface environmental monitoring technology for CO 2 leakage assessments was preliminarily confirmed at the Shenhua CCS site. The application potential of the U-tube based monitoring technology was also demonstrated during the subsurface environmental monitoring of other CCS projects.
Angel, S. Michael
1989-01-01
Particular gases or liquids are detected with a fiber optic element (11, 11a to 11j) having a cladding or coating of a material (23, 23a to 23j) which absorbs the fluid or fluids and which exhibits a change of an optical property, such as index of refraction, light transmissiveness or fluoresence emission, for example, in response to absorption of the fluid. The fluid is sensed by directing light into the fiber optic element and detecting changes in the light, such as exit angle changes for example, that result from the changed optical property of the coating material. The fluid detector (24, 24a to 24j) may be used for such purposes as sensing toxic or explosive gases in the atmosphere, measuring ground water contamination or monitoring fluid flows in industrial processes, among other uses.
Kinetics of reciprocating drug delivery to the inner ear.
Pararas, Erin E Leary; Chen, Zhiqiang; Fiering, Jason; Mescher, Mark J; Kim, Ernest S; McKenna, Michael J; Kujawa, Sharon G; Borenstein, Jeffrey T; Sewell, William F
2011-06-10
Reciprocating drug delivery is a means of delivering soluble drugs directly to closed fluid spaces in the body via a single cannula without an accompanying fluid volume change. It is ideally suited for drug delivery into small, sensitive and unique fluid spaces such as the cochlea. We characterized the pharmacokinetics of reciprocating drug delivery to the scala tympani within the cochlea by measuring the effects of changes in flow parameters on the distribution of drug throughout the length of the cochlea. Distribution was assessed by monitoring the effects of DNQX, a reversible glutamate receptor blocker, delivered directly to the inner ear of guinea pigs using reciprocating flow profiles. We then modeled the effects of those parameters on distribution using both an iterative curve-fitting approach and a computational fluid dynamic model. Our findings are consistent with the hypothesis that reciprocating delivery distributes the drug into a volume in the base of the cochlea, and suggest that the primary determinant of distribution throughout more distal regions of the cochlea is diffusion. Increases in flow rate distributed the drug into a larger volume that extended more apically. Over short time courses (less than 2h), the apical extension, though small, significantly enhanced apically directed delivery of drug. Over longer time courses (>5h) or greater distances (>3mm), maintenance of drug concentration in the basal scala tympani may prove more advantageous for extending apical delivery than increases in flow rate. These observations demonstrate that this reciprocating technology is capable of providing controlled delivery kinetics to the closed fluid space in the cochlea, and may be suitable for other applications such as localized brain and retinal delivery. Copyright © 2011 Elsevier B.V. All rights reserved.
Kinetics of Reciprocating Drug Delivery to the Inner Ear
Leary Pararas, Erin E.; Chen, Zhiqiang; Fiering, Jason; Mescher, Mark J.; Kim, Ernest S.; McKenna, Michael J.; Kujawa, Sharon G.; Borenstein, Jeffrey T.; Sewell, William F.
2011-01-01
Reciprocating drug delivery is a means of delivering soluble drugs directly to closed fluid spaces in the body via a single cannula without an accompanying fluid volume change. It is ideally suited for drug delivery into small, sensitive and unique fluid spaces such as the cochlea. We characterized the pharmacokinetics of reciprocating drug delivery to the scala tympani within the cochlea by measuring the effects of changes in flow parameters on the distribution of drug throughout the length of the cochlea. Distribution was assessed by monitoring the effects of DNQX, a reversible glutamate receptor blocker, delivered directly to the inner ear of guinea pigs using reciprocating flow profiles. We then modeled the effects of those parameters on distribution using both an iterative curve-fitting approach and a computational fluid dynamic model. Our findings are consistent with the hypothesis that reciprocating delivery distributes the drug into a volume in the base of the cochlea, and suggest that the primary determinant of distribution throughout more distal regions of the cochlea is diffusion. Increases in flow rate distributed the drug into a larger volume that extended more apically. Over short time courses (less than 2 h), the apical extension, though small, significantly enhanced apically directed delivery of drug. Over longer time courses (>5 h) or greater distances (>3 mm), maintenance of drug concentration in the basal scala tympani may prove more advantageous for extending apical delivery than increases in flow rate. These observations demonstrate that this reciprocating technology is capable of providing controlled delivery kinetics to the closed fluid space in the cochlea, and may be suitable for other applications such as localized brain and retinal delivery. PMID:21385596
Fluid flow measurements by means of vibration monitoring
NASA Astrophysics Data System (ADS)
Campagna, Mauro M.; Dinardo, Giuseppe; Fabbiano, Laura; Vacca, Gaetano
2015-11-01
The achievement of accurate fluid flow measurements is fundamental whenever the control and the monitoring of certain physical quantities governing an industrial process are required. In that case, non-intrusive devices are preferable, but these are often more sophisticated and expensive than those which are more common (such as nozzles, diaphrams, Coriolis flowmeters and so on). In this paper, a novel, non-intrusive, simple and inexpensive methodology is presented to measure the fluid flow rate (in a turbulent regime) whose physical principle is based on the acquisition of transversal vibrational signals induced by the fluid itself onto the pipe walls it is flowing through. Such a principle of operation would permit the use of micro-accelerometers capable of acquiring and transmitting the signals, even by means of wireless technology, to a control room for the monitoring of the process under control. A possible application (whose feasibility will be investigated by the authors in a further study) of this introduced technology is related to the employment of a net of micro-accelerometers to be installed on pipeline networks of aqueducts. This apparatus could lead to the faster and easier detection and location of possible leaks of fluid affecting the pipeline network with more affordable costs. The authors, who have previously proven the linear dependency of the acceleration harmonics amplitude on the flow rate, here discuss an experimental analysis of this functional relation with the variation in the physical properties of the pipe in terms of its diameter and constituent material, to find the eventual limits to the practical application of the measurement methodology.
2015-09-01
Nerve Allografts plus amniotic Fluid Derived Stem Cells (AFS). PRINCIPAL INVESTIGATOR: Li, Zhongyu CONTRACTING ORGANIZATION: Wake Forest ...NUMBER: Wake Forest University Health Sciences Medical Center Boulevard Winston-Salem, NC 27157 9. SPONSORING / MONITORING AGENCY NAME(S) AND
New Isotopic Tracers for Shale Gas and Hydraulic Fracturing Fluids
The combined application of geochemistry, stable isotopes (δ18O, δ2H), strontium isotopes (87Sr/86Sr), boron isotopes (δ11B), and radium isotopes (228Ra/226Ra) provides a unique methodology for tracing and monitoring shale gas and fracking fluids in the environment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
O`Brien, R.J.
Compliance emissions testing and Volatile Organic Compound (VOC) destruction efficiency determination were conducted on the Sudden Expansion (SUE) Incinerator located at the Kelly AFB Fuel Accessory Test Facility, Bldg 348. The purpose of the Kelly AFB SUE Incinerator is to destroy calibration fluid vapors emitted from fuel accessory test stands located in Bldg 348. The incinerator can also be used to destroy liquid waste calibration fluid by burning it as a supplemental fuel. Emissions testing was conducted during combustion of both vapors and liquid calibration fluid. For purposes of determining the incinerator VOC destruction efficiency, monitoring for Total VOC concentrationmore » in the inlet air stream was conducted on 19-20 July 1995. Emissions testing of the incinerator exhaust was conducted on 10-11 January 1996 and included monitoring for Total VOC, oxides of nitrogen (NOx), carbon monoxide (CO), and visible emissions.« less
[GOAL-DIRECTED FLUID THERAPY IN SEVERE CONCOMITANT TRAUMA].
Konkaev, A K; Gurbanova, E I; Mynbaeva, Z N
2015-01-01
We examined 78 patients with severe concomitant injury. Were evaluated the severity of the injury and indices of volumetric haemodynamic monitoring by PICCO. The retrospective comparison group consisted of 50 patients with severe concomitant injury who were treated in the ICU of Trauma Institution during 2009-2011. In patients with severe concomitant injury goal-directed fluid therapy based on PICCO monitoring parameters increasing the volume of infusion on the second and third post-traumatic days by 45% and 24%, respectively (< 0.05). Infusion-related pulmonary complications in the study group patients were not recorded Goal-directed fluid therapy was one of the factors that made it possible to reduce patient's mortality 2.1 times on conditions that severity of the injury and the initial state were similar. Colloid (6% HES 200/0.5) infusion was associated with increases in rate of transient azotemia.
2012-01-01
Introduction Fluid overload is a clinical problem frequently related to cardiac and renal dysfunction. The aim of this study was to evaluate fluid overload and changes in serum creatinine as predictors of cardiovascular mortality and morbidity after cardiac surgery. Methods Patients submitted to heart surgery were prospectively enrolled in this study from September 2010 through August 2011. Clinical and laboratory data were collected from each patient at preoperative and trans-operative moments and fluid overload and creatinine levels were recorded daily after cardiac surgery during their ICU stay. Fluid overload was calculated according to the following formula: (Sum of daily fluid received (L) - total amount of fluid eliminated (L)/preoperative weight (kg) × 100). Preoperative demographic and risk indicators, intra-operative parameters and postoperative information were obtained from medical records. Patients were monitored from surgery until death or discharge from the ICU. We also evaluated the survival status at discharge from the ICU and the length of ICU stay (days) of each patient. Results A total of 502 patients were enrolled in this study. Both fluid overload and changes in serum creatinine correlated with mortality (odds ratio (OR) 1.59; confidence interval (CI): 95% 1.18 to 2.14, P = 0.002 and OR 2.91; CI: 95% 1.92 to 4.40, P <0.001, respectively). Fluid overload played a more important role in the length of intensive care stay than changes in serum creatinine. Fluid overload (%): b coefficient = 0.17; beta coefficient = 0.55, P <0.001); change in creatinine (mg/dL): b coefficient = 0.01; beta coefficient = 0.11, P = 0.003). Conclusions Although both fluid overload and changes in serum creatinine are prognostic markers after cardiac surgery, it seems that progressive fluid overload may be an earlier and more sensitive marker of renal dysfunction affecting heart function and, as such, it would allow earlier intervention and more effective control in post cardiac surgery patients. PMID:22651844
NASA Astrophysics Data System (ADS)
Cappa, F.; Guglielmi, Y.; De Barros, L.; Wynants-Morel, N.; Duboeuf, L.
2017-12-01
During fluid injection, the observations of an enlarging cloud of seismicity are generally explained by a direct response to the pore pressure diffusion in a permeable fractured rock. However, fluid injection can also induce large aseismic deformations which provide an alternative mechanism for triggering and driving seismicity. Despite the importance of these two mechanisms during fluid injection, there are few studies on the effects of fluid pressure on the partitioning between seismic and aseismic motions under controlled field experiments. Here, we describe in-situ meter-scale experiments measuring synchronously the fluid pressure, the fault motions and the seismicity directly in a fault zone stimulated by controlled fluid injection at 280 m depth in carbonate rocks. The experiments were conducted in a gallery of an underground laboratory in south of France (LSBB, http://lsbb.eu). Thanks to the proximal monitoring at high-frequency, our data show that the fluid overpressure mainly induces a dilatant aseismic slip (several tens of microns up to a millimeter) at the injection. A sparse seismicity (-4 < Mw < -3) is observed several meters away from the injection, in a part of the fault zone where the fluid overpressure is null or very low. Using hydromechanical modeling with friction laws, we simulated an experiment and investigated the relative contribution of the fluid pressure diffusion and stress transfer on the seismic and aseismic fault behavior. The model reproduces the hydromechanical data measured at injection, and show that the aseismic slip induced by fluid injection propagates outside the pressurized zone where accumulated shear stress develops, and potentially triggers seismicity. Our models also show that the permeability enhancement and friction evolution are essential to explain the fault slip behavior. Our experimental results are consistent with large-scale observations of fault motions at geothermal sites (Wei et al., 2015; Cornet, 2016), and suggest that controlled field experiments at meter-scale are important for better assessing the role of fluid pressure in natural and human-induced earthquakes.
Papaseit, Esther; Farré, Magí; Graziano, Silvia; Pacifici, Roberta; Pérez-Mañá, Clara; García-Algar, Oscar; Pichini, Simona
2017-03-01
Electronic cigarettes (e-cig) known as electronic nicotine devices recently gained popularity among smokers. Despite many studies investigating their safety and toxicity, few examined the delivery of e-cig-derived nicotine and its metabolites in alternative biological fluids. We performed a randomized, crossover, and controlled clinical trial in nine healthy smokers. Nicotine (NIC), cotinine (COT), and trans-3'-hydroxycotinine (3-HCOT) were measured in plasma and oral fluid by liquid chromatography-tandem mass spectrometry after consumption of two consecutive e-cig administrations or two consecutive tobacco cigarettes. NIC and its metabolites were detected both in oral fluid and plasma following both administration conditions. Concentrations in oral fluid resulted various orders of magnitude higher than those observed in plasma. Oral fluid concentration of tobacco cigarette and e-cig-derived NIC peaked at 15 min after each administration and ranged between 1.0 and 1396 μg/L and from 0.3 to 860 μg/L; those of COT between 52.8 and 110 μg/L and from 33.8 to 94.7 μg/L; and those of 3-HCOT between 12.4 and 23.5 μg/L and from 8.5 to 24.4 μg/L. The oral fluid to plasma concentration ratio of both e-cig- and tobacco cigarette-derived NIC peaked at 15 min after both administrations and correlated with oral fluid NIC concentration. The obtained results support the measurement of NIC and metabolites in oral fluid in the assessment of intake after e-cig use and appear to be a suitable alternative to plasma when monitoring nicotine delivery from e-cig for clinical and toxicological studies.
Jaffrin, M Y; Maasrani, M; Le Gourrier, A; Boudailliez, B
1997-05-01
A method is presented for monitoring the relative variation of extracellular and intracellular fluid volumes using a multifrequency impedance meter and the Cole-Cole extrapolation technique. It is found that this extrapolation is necessary to obtain reliable data for the resistance of the intracellular fluid. The extracellular and intracellular resistances can be approached using frequencies of, respectively, 5 kHz and 1000 kHz, but the use of 100 kHz leads to unacceptable errors. In the conventional treatment the overall relative variation of intracellular resistance is found to be relatively small.
Geophysical Signatures to Monitor Fluids and Mineralization for CO2 Sequestration in Basalts
NASA Astrophysics Data System (ADS)
Otheim, L. T.; Adam, L.; Van Wijk, K.; Batzle, M. L.; Mcling, T. L.; Podgorney, R. K.
2011-12-01
Carbon dioxide sequestration in large reservoirs can reduce emissions of this green house gas into the atmosphere. Basalts are promising host rocks due to their volumetric extend, worldwide distribution, and recent observations that CO2-water mixtures react with basalt minerals to precipitate as carbonate minerals, trapping the CO2. The chemical reaction between carbonic acid and minerals rich in calcium, magnesium and iron precipitates carbonates in the pore space. This process would increase the elastic modulus and velocity of the rock. At the same time, the higher compressibility of CO2 over water changes the elastic properties of the rock, decreasing the saturated rock bulk modulus and the P-wave velocity. Reservoirs where the rock properties change as a result of fluid or pressure changes are commonly monitored with seismic methods. Here we present experiments to study the feasibility of monitoring CO2 migration in a reservoir and CO2-rock reactions for a sequestration scenario in basalts. Our goal is to measure the rock's elastic response to mineralization with non-contacting ultrasonic lasers, and the effect of fluid substitution at reservoir conditions at seismic and ultrasonic frequencies. For the fluid substitution experiment we observe changes in the P- and S-wave velocities when saturating the sample with super-critical (sc) CO2, CO2-water mixtures and water alone for different pore and confining pressures. The bulk modulus of the rock is significantly dependent on frequency in the 2~to 106~Hz range, for CO2-water mixtures and pure water saturations. Dry and pure CO2 (sc or gas) do not show a frequency dependence on the modulus. Moreover, the shear wave modulus is not dispersive for either fluid. The frequency dependence of the elastic parameters is related to the attenuation (1/Q) of the rock. We will show the correlation between frequency dependent moduli and attenuation data for the different elastic moduli of the rocks. Three other basalt samples were stored in a pressure chamber with a sc CO2-water solution to study the effect of mineralization on the elastic properties of the rock. The rock elastic properties are recorded with non-contacting ultrasonic lasers at room conditions. After 15 weeks the first post-mineralization scan showed differences in the rock velocities with respect to the pre-mineralization scan. The analysis is done through coda wave interferometry and direct arrivals. The samples were inserted back into the pressure vessel for continuing mineralization and subsequent scans. Finally, we will discuss the applicability of Gassmann's equation and how the combination of mineralization together with CO2-water mixture affects the velocity of waves in basalt rocks.
Lubricant retention in liquid-infused microgrooves exposed to turbulent flow
NASA Astrophysics Data System (ADS)
Fu, Matthew; Chen, Ting-Hsuan; Arnold, Craig; Hultmark, Marcus
2017-11-01
Liquid infused surfaces are a promising method of passive drag reduction for turbulent flows. These surfaces rely on functionalized roughness elements to trap a liquid lubricant that is immiscible with external fluids. The presence of the lubricant creates a collection of fluid-fluid interfaces which can support a finite slip velocity at the effective surface. Generating a streamwise slip at the surface has been demonstrated as an effective mechanism for drag reduction; however, sustained drag reduction is predicated on the retention of the lubricating layer. Here, a turbulent channel-flow facility is used to characterize the robustness of liquid-infused surfaces and evaluate criteria for ensuring retention of the lubricant. Microscale grooved surfaces infused with alkane lubricants are mounted flush in the channel and exposed to turbulent flows. The retention of lubricants and pressure drop are monitored to characterize the effects of surface geometry and lubricant properties. To improve the retention of lubricant within grooved structures, a novel laser patterning technique is used to scribe chemical barriers onto grooved surfaces and evaluated. Supported under ONR Grants N00014-12-1-0875 and N00014-12-1-0962 (program manager Ki-Han Kim) and by the Department of Defense (DoD) through the National Defense Science & Engineering Graduate Fellowship (NDSEG) Program.
Screen and effect analysis of immunostimulants for sea cucumber, Apostichopus japonicus
NASA Astrophysics Data System (ADS)
Li, Jiye; Sun, Xiuqin; Zheng, Fengrong; Hao, Linhua
2009-02-01
Immunostimulants may improve disease resistance of aquaculture animals by promoting the nonspecific immunity response of the organisms. Five types of saccharides, including chitosan, yeast polysaccharide, burdock oligosaccharide, seaweed polysaccharide and lentinus edodes polysaccharide, were screened for potential use as immunostimulants by using spectrophotometry. The saccharides were injected into Apostichopus japonicus, a sea cucumber, and the lysozyme and superoxide dismutase (SOD) activities of the coelomic fluid and epidermal slime were monitored in six consecutive days. The results show that the lysozyme activity of the animal’s coelomic fluid was significantly stimulated on day 2, day 4 and day 6 after the injection of the saccharides ( P<0.05). The effects of chitosan and yeast polysaccharide were the most notable. The lysozyme activity of the epidermal slime was significantly increased by chitosana, yeast polysaccharide, seaweed polysaccharide, and burdock oligosaccharide on day 1 and day 2 after the injection ( P<0.05). The SOD activity of the coelomic fluid was significantly promoted by the saccharides on day 2 and day 4 post-injection ( P<0.05), while the SOD activity of the epidermal slime increased on day 2. These findings indicate that chitosan and yeast polysaccharide are the most effective immunostimulants and potential healthy anti-disease feedstuff for A. japonicus.
Cause-and-effect relationships in tandem swimmer models using transfer entropy
NASA Astrophysics Data System (ADS)
Peterson, Sean; Rosen, Maxwell; Gementzopoulos, Antonios; Zhang, Peng; Porfiri, Maurizio
2017-11-01
Swimming in a group affords a number of advantages to fish, including an enhanced ability to escape from predators, search for food, and mate. To study coordinated movements of fish, principled approaches are needed to unravel cause-and-effect relationships from raw-time series of multiple bodies moving in an encompassing fluid. In this work, we aim at demonstrating the validity of transfer entropy to elucidate cause-and-effect relationships in a fluid-structure interaction problem. Specifically, we consider two tandem airfoils in a uniform flow, wherein the pitching angle of one airfoil is actively controlled while the other is allowed to passively rotate. The active control alternates the pitch angle based upon an underlying two-state ergodic Markov process. We monitor the pitch angle of both the active and passive airfoils in time and demonstrate that transfer entropy can detect causality independent of which airfoil is actuated. The influence estimated by transfer entropy is found to be modulated by the distance between the two airfoils. The proposed data-driven technique offers a model-free perspective on fluid-structure interactions that can help illuminate the mechanisms of swimming in coordination. This work was supported by the National Science Foundation under Grant Numbers CBET-1332204 and CMMI-1433670.
NASA Technical Reports Server (NTRS)
Tiwari, Vidhu S.; Kalluru, Rajamohan R.; Yueh, Fang-Yu; Singh, Jagdish P.; SaintCyr, William
2007-01-01
A spontaneous Raman scattering optical fiber sensor is developed for a specific need of NASA/SSC for long-term detection and monitoring of the quality of liquid oxygen (LOX) in the delivery line during ground testing of rocket engines. The sensor performance was tested in the laboratory and with different excitation light sources. To evaluate the sensor performance with different excitation light sources for the LOX quality application, we have used the various mixtures of liquid oxygen and liquid nitrogen as samples. The study of the sensor performance shows that this sensor offers a great deal of flexibility and provides a cost effective solution for the application. However, an improved system response time is needed for the real-time, quantitative monitoring of the quality of cryogenic fluids in harsh environment.
Measuring Time-Averaged Blood Pressure
NASA Technical Reports Server (NTRS)
Rothman, Neil S.
1988-01-01
Device measures time-averaged component of absolute blood pressure in artery. Includes compliant cuff around artery and external monitoring unit. Ceramic construction in monitoring unit suppresses ebb and flow of pressure-transmitting fluid in sensor chamber. Transducer measures only static component of blood pressure.
Dose-Response Evaluation of Braslet-M Occlusion Cuffs
NASA Technical Reports Server (NTRS)
Ebert, Douglas; Garcia, Kathleen; Sargsyan, Ashot E.; Ham, David; Hamilton, Douglas; Dulchavsky, Scott A.
2010-01-01
Introduction: Braslet-M is a set of special elasticized thigh cuffs used by the Russian space agency to reduce the effects of the head-ward fluid shift during early adaptation to microgravity by sequestering fluid in the lower extremities. Currently, no imaging modalities are used in the calibration of the device, and the pressure required to produce a predictable physiological response is unknown. This investigation intends to relate the pressure exerted by the cuffs to the extent of fluid redistribution and commensurate physiological effects. Materials and Methods: Ten healthy subjects with standardized fluid intake participated in the study. Data collection included femoral and internal jugular vein imaging in two orthogonal planes, pulsed Doppler of cervical and femoral vessels and middle cerebral artery, optic nerve imaging, and echocardiography. Braslet-M cuff pressure was monitored at the skin interface using pre-calibrated pressure sensors. Using 6 and 30 head-down tilt in two separate sessions, the effect of Braslet-M was assessed while incrementally tightening the cuffs. Cuffs were then simultaneously released to document the resulting hemodynamic change. Results: Preliminary analysis shows correlation between physical pressure exerted by the Braslet-M device and several parameters such as jugular and femoral vein cross-sections, resistivity of the lower extremity vascular bed, and others. A number of parameters reflect blood redistribution and will be used to determine the therapeutic range of the device and to prevent unsafe application. Conclusion: Braslet-M exerts a physical effect that can be measured and correlated with many changes in central and peripheral hemodynamics. Analysis of the full data set will be required to make definitive recommendations regarding the range of safe therapeutic application. Objective data and subjective responses suggest that a safer and equally effective use of Braslet can be achieved when compared with the current non-imaging calibration techniques.
Thermal control system. [removing waste heat from industrial process spacecraft
NASA Technical Reports Server (NTRS)
Hewitt, D. R. (Inventor)
1983-01-01
The temperature of an exothermic process plant carried aboard an Earth orbiting spacecraft is regulated using a number of curved radiator panels accurately positioned in a circular arrangement to form an open receptacle. A module containing the process is insertable into the receptacle. Heat exchangers having broad exterior surfaces extending axially above the circumference of the module fit within arcuate spacings between adjacent radiator panels. Banks of variable conductance heat pipes partially embedded within and thermally coupled to the radiator panels extend across the spacings and are thermally coupled to broad exterior surfaces of the heat exchangers by flanges. Temperature sensors monitor the temperature of process fluid flowing from the module through the heat exchanges. Thermal conduction between the heat exchangers and the radiator panels is regulated by heating a control fluid within the heat pipes to vary the effective thermal length of the heat pipes in inverse proportion to changes in the temperature of the process fluid.
Internal Fluid Dynamics and Frequency Scaling of Sweeping Jet Fluidic Oscillators
NASA Astrophysics Data System (ADS)
Seo, Jung Hee; Salazar, Erik; Mittal, Rajat
2017-11-01
Sweeping jet fluidic oscillators (SJFOs) are devices that produce a spatially oscillating jet solely based on intrinsic flow instability mechanisms without any moving parts. Recently, SJFOs have emerged as effective actuators for flow control, but the internal fluid dynamics of the device that drives the oscillatory flow mechanism is not yet fully understood. In the current study, the internal fluid dynamics of the fluidic oscillator with feedback channels has been investigated by employing incompressible flow simulations. The study is focused on the oscillation mechanisms and scaling laws that underpin the jet oscillation. Based on the simulation results, simple phenomenological models that connect the jet deflection to the feedback flow are developed. Several geometric modifications are considered in order to explore the characteristic length scales and phase relationships associated with the jet oscillation and to assess the proposed phenomenological model. A scaling law for the jet oscillation frequency is proposed based on the detailed analysis. This research is supported by AFOSR Grant FA9550-14-1-0289 monitored by Dr. Douglas Smith.
Liu, Jing; Ren, Xiao-Ling; Fu, Wei; Liu, Ying; Xia, Rong-Ming
2017-10-01
Pulmonary atelectasis (PA) is a common clinical complication among newborns, and it is one of the most common causes of neonatal dyspnea, a condition with no specific effective treatment. This study examined the effectiveness and security of bronchoalveolar lavage (BL) regarding the treatment of neonatal PA under ultrasound monitoring. A total of 57 patients diagnosed with PA via lung ultrasound (LUS) were included in this study. All patients received BL via a tracheal intubation injection of lavage fluid. The LUS was conducted immediately after each lavage to understand the conditions of lung re-expansion. Irrigation was repeated two to three times as one course of treatment. BL was provided as one to two courses of treatment daily for several days according to atelectasis and lung recruitment status. Of the 57 patients, BL was very effective in 44 cases (77.2%), marginally effective in nine cases (15.8%) and ineffective in four cases (7.0%), showing a total effective rate of 93.0%. The four ineffective cases showed a long disease duration and severe pulmonary consolidation. BL showed significant effectiveness for the treatment of neonatal PA under ultrasound monitoring. This treatment is easy to operate, and no adverse side effects were observed. Thus, BL should be considered for clinical application.
2013-01-01
In resource-rich countries, bolus fluid expansion is routinely used for the treatment of poor perfusion and shock, but is less commonly used in many African settings. Controversial results from the recently completed FEAST (Fluid Expansion As Supportive Therapy) trial in African children have raised questions about the use of intravenous bolus fluid for the treatment of shock. Prior to the start of the trial, the Independent data monitoring committee (IDMC) developed stopping rules for the proof of benefit that bolus fluid resuscitation would bring. Although careful safety monitoring was put in place, there was less expectation that bolus fluid expansion would be harmful and differential stopping rules for harm were not formulated. In July 2010, two protocol amendments were agreed to increase the sample size from 2,880 to 3,600 children, and to increase bolus fluid administration. There was a non-significant trend against bolus treatment, but although the implications were discussed, the IDMC did not comment on the results, or on the amendments, in order to avoid inadvertent partial unblinding of the study. In January 2011, the trial was stopped for futility, as the combined intervention arms had significantly higher mortality (relative risk 1.46, 95% CI 1.13 to 1.90, P = 0.004) than the control arm. The stopping rule for proof of benefit was not achieved, and the IDMC stopped the trial with a lower level of significance (P = 0.01) due to futility and an increased risk of mortality from bolus fluid expansion in children enrolled in the trial. The basis for this decision was that the local standard of care was not to use bolus fluid for the care of children with shock in these African countries, and this was a different standard of care to that used in the UK. These decisions emphasize two important principles: firstly, the IDMC should avoid inadvertent unblinding of the trial by commenting on amendments, and secondly, when considering stopping a trial, the IDMC should be guided by the local standard of care rather than standards of care in other parts of the world. PMID:23531379
Todd, Jim; Heyderman, Robert S; Musoke, Philippa; Peto, Tim
2013-03-26
In resource-rich countries, bolus fluid expansion is routinely used for the treatment of poor perfusion and shock, but is less commonly used in many African settings. Controversial results from the recently completed FEAST (Fluid Expansion As Supportive Therapy) trial in African children have raised questions about the use of intravenous bolus fluid for the treatment of shock. Prior to the start of the trial, the Independent data monitoring committee (IDMC) developed stopping rules for the proof of benefit that bolus fluid resuscitation would bring. Although careful safety monitoring was put in place, there was less expectation that bolus fluid expansion would be harmful and differential stopping rules for harm were not formulated.In July 2010, two protocol amendments were agreed to increase the sample size from 2,880 to 3,600 children, and to increase bolus fluid administration. There was a non-significant trend against bolus treatment, but although the implications were discussed, the IDMC did not comment on the results, or on the amendments, in order to avoid inadvertent partial unblinding of the study.In January 2011, the trial was stopped for futility, as the combined intervention arms had significantly higher mortality (relative risk 1.46, 95% CI 1.13 to 1.90, P = 0.004) than the control arm. The stopping rule for proof of benefit was not achieved, and the IDMC stopped the trial with a lower level of significance (P = 0.01) due to futility and an increased risk of mortality from bolus fluid expansion in children enrolled in the trial. The basis for this decision was that the local standard of care was not to use bolus fluid for the care of children with shock in these African countries, and this was a different standard of care to that used in the UK. These decisions emphasize two important principles: firstly, the IDMC should avoid inadvertent unblinding of the trial by commenting on amendments, and secondly, when considering stopping a trial, the IDMC should be guided by the local standard of care rather than standards of care in other parts of the world.
NASA Astrophysics Data System (ADS)
Falcon-Suarez, I.; North, L. J.; Best, A. I.
2017-12-01
To date, the most promising mitigation strategy for reducing global carbon emissions is Carbon Capture and Storage (CCS). The storage technology (i.e., CO2 geosequestration, CGS) consists of injecting CO2 into deep geological formations, specifically selected for such massive-scale storage. To guarantee the mechanical stability of the reservoir during and after injection, it is crucial to improve existing monitoring techniques for controlling CGS activities. We developed a comprehensive experimental program to investigate the integrity of the Sleipner CO2 storage site in the North Sea - the first commercial CCS project in history where 1 Mtn/y of CO2 has been injected since 1996. We assessed hydro-mechanical effects and the related geophysical signatures of three synthetic sandstones and samples from the Utsira Sand formation (main reservoir at Sleipner), at realistic pressure-temperature (PT) conditions and fluid compositions. Our experimental approach consists of brine-CO2 flow-through tests simulating variable inflation/depletion scenarios, performed in the CGS-rig (Fig. 1; Falcon-Suarez et al., 2017) at the National Oceanography Centre (NOC) in Southampton. The rig is designed for simultaneous monitoring of ultrasonic P- and S-wave velocities and attenuations, electrical resistivity, axial and radial strains, pore pressure and flow, during the co-injection of up to two fluids under controlled PT conditions. Our results show velocity-resistivity and seismic-geomechanical relations of practical importance for the distinction between pore pressure and pore fluid distribution during CGS activities. By combining geophysical and thermo-hydro-mechano-chemical coupled information, we can provide laboratory datasets that complement in situ seismic, geomechanical and electrical survey information, useful for the CO2 plume monitoring in Sleipner site and other shallow weakly-cemented sand CCS reservoirs. Falcon-Suarez, I., Marín-Moreno, H., Browning, F., Lichtschlag, A., Robert, K., North, L.J., Best, A.I., 2017. Experimental assessment of pore fluid distribution and geomechanical changes in saline sandstone reservoirs during and after CO2 injection. International Journal of Greenhouse Gas Control 63, 356-369.
Pressure Monitoring to Detect Fault Rupture Due to CO 2 Injection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Keating, Elizabeth; Dempsey, David; Pawar, Rajesh
The capacity for fault systems to be reactivated by fluid injection is well-known. In the context of CO 2 sequestration, however, the consequence of reactivated faults with respect to leakage and monitoring is poorly understood. Using multi-phase fluid flow simulations, this study addresses key questions concerning the likelihood of ruptures, the timing of consequent upward leakage of CO 2, and the effectiveness of pressure monitoring in the reservoir and overlying zones for rupture detection. A range of injection scenarios was simulated using random sampling of uncertain parameters. These include the assumed distance between the injector and the vulnerable fault zone,more » the critical overpressure required for the fault to rupture, reservoir permeability, and the CO 2 injection rate. We assumed a conservative scenario, in which if at any time during the five-year simulations the critical fault overpressure is exceeded, the fault permeability is assumed to instantaneously increase. For the purposes of conservatism we assume that CO 2 injection continues ‘blindly’ after fault rupture. We show that, despite this assumption, in most cases the CO 2 plume does not reach the base of the ruptured fault after 5 years. As a result, one possible implication of this result is that leak mitigation strategies such as pressure management have a reasonable chance of preventing a CO 2 leak.« less
Pressure Monitoring to Detect Fault Rupture Due to CO 2 Injection
Keating, Elizabeth; Dempsey, David; Pawar, Rajesh
2017-08-18
The capacity for fault systems to be reactivated by fluid injection is well-known. In the context of CO 2 sequestration, however, the consequence of reactivated faults with respect to leakage and monitoring is poorly understood. Using multi-phase fluid flow simulations, this study addresses key questions concerning the likelihood of ruptures, the timing of consequent upward leakage of CO 2, and the effectiveness of pressure monitoring in the reservoir and overlying zones for rupture detection. A range of injection scenarios was simulated using random sampling of uncertain parameters. These include the assumed distance between the injector and the vulnerable fault zone,more » the critical overpressure required for the fault to rupture, reservoir permeability, and the CO 2 injection rate. We assumed a conservative scenario, in which if at any time during the five-year simulations the critical fault overpressure is exceeded, the fault permeability is assumed to instantaneously increase. For the purposes of conservatism we assume that CO 2 injection continues ‘blindly’ after fault rupture. We show that, despite this assumption, in most cases the CO 2 plume does not reach the base of the ruptured fault after 5 years. As a result, one possible implication of this result is that leak mitigation strategies such as pressure management have a reasonable chance of preventing a CO 2 leak.« less
Gravitational haemodynamics and oedema prevention in the giraffe
NASA Technical Reports Server (NTRS)
Hargens, Alan R.; Millard, Ronald W.; Pettersson, Knut; Johansen, Kjell
1987-01-01
The question of how giraffes avoid pooling of blood and tissue fluid (edema) in dependent tissues of their extremities is addressed. As monitored by radiotelemetry, the blood and tissue fluid pressures that govern transcapillary exchange vary greatly with exercise. These pressures, combined with a tight skin layer, move fluid upward against gravity. The skin thus functions like a natural antigravity suit. Other mechanisms that prevent edema include precapillary vasoconstriction and low permeability of capillaries to plasma proteins.
Fluid resuscitation in acute pancreatitis
Aggarwal, Aakash; Manrai, Manish; Kochhar, Rakesh
2014-01-01
Acute pancreatitis remains a clinical challenge, despite an exponential increase in our knowledge of its complex pathophysiological changes. Early fluid therapy is the cornerstone of treatment and is universally recommended; however, there is a lack of consensus regarding the type, rate, amount and end points of fluid replacement. Further confusion is added with the newer studies reporting better results with controlled fluid therapy. This review focuses on the pathophysiology of fluid depletion in acute pancreatitis, as well as the rationale for fluid replacement, the type, optimal amount, rate of infusion and monitoring of such patients. The basic goal of fluid epletion should be to prevent or minimize the systemic response to inflammatory markers. For this review, various studies and reviews were critically evaluated, along with authors’ recommendations, for predicted severe or severe pancreatitis based on the available evidence. PMID:25561779
Billeter, Thomas R.; Philipp, Lee D.; Schemmel, Richard R.
1976-01-01
A microwave fluid flow meter is described utilizing two spaced microwave sensors positioned along a fluid flow path. Each sensor includes a microwave cavity having a frequency of resonance dependent upon the static pressure of the fluid at the sensor locations. The resonant response of each cavity with respect to a variation in pressure of the monitored fluid is represented by a corresponding electrical output which can be calibrated into a direct pressure reading. The pressure drop between sensor locations is then correlated as a measure of fluid velocity. In the preferred embodiment the individual sensor cavities are strategically positioned outside the path of fluid flow and are designed to resonate in two distinct frequency modes yielding a measure of temperature as well as pressure. The temperature response can then be used in correcting for pressure responses of the microwave cavity encountered due to temperature fluctuations.
Monitoring needs and goal-directed fluid therapy within an enhanced recovery program.
Minto, Gary; Scott, Michael J; Miller, Timothy E
2015-03-01
Patients having major abdominal surgery need perioperative fluid supplementation; however, enhanced recovery principles mitigate against many of the factors that traditionally led to relative hypovolemia in the perioperative period. An estimate of fluid requirements for abdominal surgery can be made but individualization of fluid prescription requires consideration of clinical signs and hemodynamic variables. The literature supports goal-directed fluid therapy. Application of this evidence to justify stroke volume optimization in the setting of major surgery within an enhanced recovery program is controversial. This article places the evidence in context, reviews controversies, and suggests implications for current practice and future research. Copyright © 2015 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Strehlow, Karen; Gottsmann, Jo
2014-05-01
Aquifers respond to and modify the surface expressions of magmatic activity, and they can also become agents of unrest themselves. Therefore, monitoring the hydrology can provide a valuable window into subsurface processes in volcanic areas. Interpretations of unrest signals as groundwater responses to changes in the magmatic system can be found for many volcanoes. Changes in temperature and strain conditions, seismic excitation or the injection of magmatic fluids into hydrothermal systems are just a few of the proposed processes induced by magmatic activity that affect the local hydrology. Aquifer responses are described to include changes in water table levels, changes in temperature or composition of hydrothermal waters and pore pressure-induced ground deformation. We can observe these effects at the surface via geophysical and geochemical signals. To fully to utilise these indicators as monitoring and forecasting tools, however, it is necessary to improve our still poor understanding of the ongoing mechanisms in the interactions of hydrological and magmatic systems. An extensive literature research provided an overview on reported effects, which we investigate in detail using numerical modelling. The hydrogeophysical study uses finite element analysis to quantitatively test proposed mechanisms of aquifer excitation and the resultant geophysical signals. We present a set of generic models for two typical volcanic landforms - a stratovolcano and a caldera - that simulate the interaction between deeper magmatic systems with shallow-seated aquifers, focusing on strain and temperature effects. They predict pore pressure induced hydraulic head changes in the aquifer as well as changing groundwater temperatures and strain induced fluid migration. Volcano observatories can track these hydrological effects for example with potential field investigations or the monitoring of wells. The models allow us to explore the parameter space, contributing to a better understanding of the coupling of these two highly complex systems. Our results provide further insight into the subsurface processes at volcanic systems and will aid the evaluation of unrest signals with potential for improved eruption forecasting.
40 CFR 61.242-2 - Standards: Pumps.
Code of Federal Regulations, 2011 CFR
2011-07-01
... fluid degassing reservoir that is routed to a process or fuel gas system or connected by a closed-vent..., is not in VOC service. (3) Each barrier fluid system is equipped with a sensor that will detect... employ a gas chromatography column to limit the response of the monitor to VHAP, at the option of the...
40 CFR 61.242-2 - Standards: Pumps.
Code of Federal Regulations, 2010 CFR
2010-07-01
... fluid degassing reservoir that is routed to a process or fuel gas system or connected by a closed-vent..., is not in VOC service. (3) Each barrier fluid system is equipped with a sensor that will detect... employ a gas chromatography column to limit the response of the monitor to VHAP, at the option of the...
Evolution of a fracture network in an elastic medium with internal fluid generation and expulsion
NASA Astrophysics Data System (ADS)
Kobchenko, Maya; Hafver, Andreas; Jettestuen, Espen; Renard, François; Galland, Olivier; Jamtveit, Bjørn; Meakin, Paul; Dysthe, Dag Kristian
2014-11-01
A simple and reproducible analog experiment was used to simulate fracture formation in a low-permeability elastic solid during internal fluid/gas production, with the objective of developing a better understanding of the mechanisms that control the dynamics of fracturing, fracture opening and closing, and fluid transport. In the experiment, nucleation, propagation, and coalescence of fractures within an elastic gelatin matrix, confined in a Hele-Shaw cell, occurred due to CO2 production via fermentation of sugar, and it was monitored by optical means. We first quantified how a fracture network develops, and then how intermittent fluid transport is controlled by the dynamics of opening and closing of fractures. The gas escape dynamics exhibited three characteristic behaviors: (1) Quasiperiodic release of gas with a characteristic frequency that depends on the gas production rate but not on the system size. (2) A 1 /f power spectrum for the fluctuations in the total open fracture area over an intermediate range of frequencies (f ), which we attribute to collective effects caused by interaction between fractures in the drainage network. (3) A 1 /f2 power spectrum was observed at high frequencies, which can be explained by the characteristic behavior of single fractures.
Preface: Current perspectives in modelling, monitoring, and predicting geophysical fluid dynamics
NASA Astrophysics Data System (ADS)
Mancho, Ana M.; Hernández-García, Emilio; López, Cristóbal; Turiel, Antonio; Wiggins, Stephen; Pérez-Muñuzuri, Vicente
2018-02-01
The third edition of the international workshop Nonlinear Processes in Oceanic and Atmospheric Flows
was held at the Institute of Mathematical Sciences (ICMAT) in Madrid from 6 to 8 July 2016. The event gathered oceanographers, atmospheric scientists, physicists, and applied mathematicians sharing a common interest in the nonlinear dynamics of geophysical fluid flows. The philosophy of this meeting was to bring together researchers from a variety of backgrounds into an environment that favoured a vigorous discussion of concepts across different disciplines. The present Special Issue on Current perspectives in modelling, monitoring, and predicting geophysical fluid dynamics
contains selected contributions, mainly from attendants of the workshop, providing an updated perspective on modelling aspects of geophysical flows as well as issues on prediction and assimilation of observational data and novel tools for describing transport and mixing processes in these contexts. More details on these aspects are discussed in this preface.
Bioanalytical procedures for monitoring in utero drug exposure
Gray, Teresa
2009-01-01
Drug use by pregnant women has been extensively associated with adverse mental, physical, and psychological outcomes in their exposed children. This manuscript reviews bioanalytical methods for in utero drug exposure monitoring for common drugs of abuse in urine, hair, oral fluid, blood, sweat, meconium, amniotic fluid, umbilical cord tissue, nails, and vernix caseosa; neonatal matrices are particularly emphasized. Advantages and limitations of testing different maternal and neonatal biological specimens including ease and invasiveness of collection, and detection time frames, sensitivities, and specificities are described, and specific references for available analytical methods included. Future research involves identifying metabolites unique to fetal drug metabolism to improve detection rates of in utero drug exposure and determining relationships between the amount, frequency, and timing of drug exposure and drug concentrations in infant biological fluids and tissues. Accurate bioanalytical procedures are vital to defining the scope of and resolving this important public health problem. PMID:17370066
Kroon Van Diest, Ashley M; Ramsey, Rachelle; Aylward, Brandon; Kroner, John W; Sullivan, Stephanie M; Nause, Katie; Allen, Janelle R; Chamberlin, Leigh A; Slater, Shalonda; Hommel, Kevin; LeCates, Susan L; Kabbouche, Marielle A; O'Brien, Hope L; Kacperski, Joanne; Hershey, Andrew D; Powers, Scott W
2016-07-01
The purpose of this investigation was to examine treatment adherence to medication and lifestyle recommendations among pediatric migraine patients using electronic monitoring systems. Nonadherence to medical treatment is a significant public health concern, and can result in poorer treatment outcomes, decreased cost-effectiveness of medical care, and increased morbidity. No studies have systematically examined adherence to medication and lifestyle recommendations in adolescents with migraine outside of a clinical trial. Participants included 56 adolescents ages 11-17 who were presenting for clinical care. All were diagnosed with migraine with or without aura or chronic migraine and had at least 4 headache days per month. Medication adherence was objectively measured using electronic monitoring systems (Medication Event Monitoring Systems technology) and daily, prospective self-report via personal electronic devices. Adherence to lifestyle recommendations of regular exercise, eating, and fluid intake were also assessed using daily self-report on personal electronic devices. Electronic monitoring indicates that adolescents adhere to their medication 75% of the time, which was significantly higher than self-reported rates of medication adherence (64%). Use of electronic monitoring of medication detected rates of adherence that were significantly higher for participants taking once daily medication (85%) versus participants taking twice daily medication (59%). Average reported adherence to lifestyle recommendations of consistent noncaffeinated fluid intake (M = 5 cups per day) was below recommended levels of a minimum of 8 cups per day. Participants on average also reported skipping 1 meal per week despite recommendations of consistently eating three meals per day. Results suggest that intervention focused on adherence to preventive treatments (such as medication) and lifestyle recommendations may provide more optimal outcomes for children and adolescents with migraine and their families. Once daily dosing of medication may be preferred to twice daily medication for increased medication adherence among children and adolescents. © 2016 American Headache Society.
Magnetic effect for electrochemically driven cellular convection.
Nakabayashi, S; Inokuma, K; Karantonis, A
1999-06-01
Hydrodynamic instability analogous to Rayleigh-Bénard convection is observed in an electrolytic solution between two parallel copper wire electrodes. The laser interferometric technique can reveal the dissipation structure created by the motion of the fluid, which is controlled electrochemically. It is shown that under the presence of horizontal magnetic field the roll cells move horizontally along the electrodes. The electrochemically driven convection is simply controlled and monitored by setting and measuring the electrochemical parameters and forms many kinds of spatiotemporal patterns, especially under the magnetic field. The phenomenon is modeled by considering a Boussinesq fluid under a concentration gradient. The stability of the resulting equations is studied by linear stability analysis. The time dependent nonlinear system is investigated numerically and the main features of the experimental response are reproduced.
Battiste, Richard L.
2007-12-25
Methods and apparatus are described for characterizing the temporal-spatial properties of a dynamic fluid front within a mold space while the mold space is being filled with fluid. A method includes providing a mold defining a mold space and having one or more openings into the mold space; heating a plurality of temperature sensors that extend into the mold space; injecting a fluid into the mold space through the openings, the fluid experiencing a dynamic fluid front while filling the mold space with the fluid; and characterizing temporal-spatial properties of the dynamic fluid front by monitoring a temperature of each of the plurality of heated temperature sensors while the mold space is being filled with the fluid. An apparatus includes a mold defining a mold space; one or more openings for introducing a fluid into the mold space and filling the mold space with the fluid, the fluid experiencing a dynamic fluid front while filling the mold space; a plurality of heated temperature sensors extending into the mold space; and a computer coupled to the plurality of heated temperature sensors for characterizing the temporal-spatial properties of the dynamic fluid front.
Battiste, Richard L
2013-12-31
Methods and apparatus are described for characterizing the temporal-spatial properties of a dynamic fluid front within a mold space while the mold space is being filled with fluid. A method includes providing a mold defining a mold space and having one or more openings into the mold space; heating a plurality of temperature sensors that extend into the mold space; injecting a fluid into th emold space through the openings, the fluid experiencing a dynamic fluid front while filling the mold space with a fluid; and characterizing temporal-spatial properties of the dynamic fluid front by monitoring a termperature of each of the plurality of heated temperature sensors while the mold space is being filled with the fluid. An apparatus includes a mold defining a mold space; one or more openings for introducing a fluid into th emold space and filling the mold space with the fluid, the fluid experiencing a dynamic fluid front while filling the mold space; a plurality of heated temperature sensors extending into the mold space; and a computer coupled to the plurality of heated temperature sensors for characterizing the temporal-spatial properties of the dynamic fluid front.
NASA Astrophysics Data System (ADS)
Kang, S.; Lim, S. K.; Oldenburg, D.
2016-12-01
Fluid flow in an underground porous medium pulls positive ions in the direction of flow and results in a streaming current. This movement of ions in the direction of flow creates a charge imbalance in the system which, in turn, causes conduction currents to flow in the opposite Although, the streaming current only flows in the saturated pores, the conduction currents will flow in the entire medium. The electrical potentials due to the fluid flow can be measured in the same manner as those in a direct current survey. This method is often called the self-potential (SP) method. A number of applications using the SP technique have been investigated including earthquake prediction, the vadose zone flow, locating sinkholes, mineral deposits and volcanic chambers. In this study, we particularly focus on the monitoring of seepage flow through earth dams. Earth dams are usually made of permeable materials and are designed to allow limited amounts of seepage flow from the reservoir. Due to seepage forces, the fine grains in the core can be washed out, and this internal erosion is one the most prevalent failure modes in earth dams. Therefore, identifying and monitoring the region of preferential seepage flow is a key for dam safety assessment. Usually, an earth dam is composed of fine-grained core and coarse-grained cover, which have different hydraulic conductivities. The distribution of hydraulic head, water saturation and fluid flow is found by solving hydrogeologic equations with applied boundary conditions. When a seepage path is induced due to internal erosion, the hydrological properties will be changed and this results in additional fluid flow. This is an additional source of SP signal. Understanding the impact of different sources of the SP signals is thus a crucial factor towards effective use of the SP technique for safety assessment at earth dams. Modelling SP signals requires two essential simulation capabilities: a) computing fluid flow in porous medium and b) solving steady-state Maxwell's equations. Since they are coupled having both systems in a single framework will be beneficial. This also allows the fundamentals of SP signals to be explored. By using an open-source modular framework, SimPEG, we develop an SP simulation package and demonstrate its effective use for understanding SP signals with an earth dam setup.
[Gastric mucosa tonometry in routine monitoring in the surgical intensive care unit].
Pestel, G; Uhlig, T; Götschl, A; Schmucker, P; Rothhammer, A
1998-06-01
Monitoring tissue oxygenation in the splanchnic region could be helpful for critically ill patients. In this study the postoperative course of gastric mucosal CO2 (prCO2) in 40 patients is shown. Following approval of the ethics committee, 24 patients schedulded for surgery with an expected large fluid turnover and 16 multiple injured patients were monitored with a gas tonometry device in addition to standard monitoring (ECG, pulse oximetry, capnometry, CVP, arterial pressure). Normoventilated patients with prCO2 > 50 for more than 30 minutes were treated with fluid therapy, followed by catecholamine therapy, followed by transfusion (fig. 1). All patients were admitted to the SICU post-operatively. The variation of prCO2-values was greater in multiple injured patients. Their prCO2-values began in a lower range compared to patients with scheduled operation, became higher at the end of the first SICU-day and remained higher thereafter. They had a higher fluid turnover and needed more catecholamines. Multiple injured patients with an arterio-intestinal CO2-Difference (CO2-Gap) > 10 had a higher ISS-Score, were longer mechanically ventilated, had a longer SICU-stay and a higher incidence of complications in comparison to patients with aCO2-Gap < 10. Perhaps a CO2-Gap > 10 could be predictive for a more severe course in intensive care patients.
In vivo monitoring of neuronal loss in traumatic brain injury: a microdialysis study
Tisdall, Martin M.; Girbes, Armand R.; Martinian, Lillian; Thom, Maria; Kitchen, Neil; Smith, Martin
2011-01-01
Traumatic brain injury causes diffuse axonal injury and loss of cortical neurons. These features are well recognized histologically, but their in vivo monitoring remains challenging. In vivo cortical microdialysis samples the extracellular fluid adjacent to neurons and axons. Here, we describe a novel neuronal proteolytic pathway and demonstrate the exclusive neuro-axonal expression of Pavlov’s enterokinase. Enterokinase is membrane bound and cleaves the neurofilament heavy chain at positions 476 and 986. Using a 100 kDa microdialysis cut-off membrane the two proteolytic breakdown products, extracellular fluid neurofilament heavy chains NfH476−986 and NfH476−1026, can be quantified with a relative recovery of 20%. In a prospective clinical in vivo study, we included 10 patients with traumatic brain injury with a median Glasgow Coma Score of 9, providing 640 cortical extracellular fluid samples for longitudinal data analysis. Following high-velocity impact traumatic brain injury, microdialysate extracellular fluid neurofilament heavy chain levels were significantly higher (6.18 ± 2.94 ng/ml) and detectable for longer (>4 days) compared with traumatic brain injury secondary to falls (0.84 ± 1.77 ng/ml, <2 days). During the initial 16 h following traumatic brain injury, strong correlations were found between extracellular fluid neurofilament heavy chain levels and physiological parameters (systemic blood pressure, anaerobic cerebral metabolism, excessive brain tissue oxygenation, elevated brain temperature). Finally, extracellular fluid neurofilament heavy chain levels were of prognostic value, predicting mortality with an odds ratio of 7.68 (confidence interval 2.15–27.46, P = 0.001). In conclusion, this study describes the discovery of Pavlov’s enterokinase in the human brain, a novel neuronal proteolytic pathway that gives rise to specific protein biomarkers (NfH476−986 and NfH476−1026) applicable to in vivo monitoring of diffuse axonal injury and neuronal loss in traumatic brain injury. PMID:21278408
Stens, Jurre; Oeben, Jeroen; Van Dusseldorp, Ab A; Boer, Christa
2016-10-01
Nexfin beat-to-beat arterial blood pressure monitoring enables continuous assessment of hemodynamic indices like cardiac index (CI), pulse pressure variation (PPV) and stroke volume variation (SVV) in the perioperative setting. In this study we investigated whether Nexfin adequately reflects alterations in these hemodynamic parameters during a provoked fluid shift in anesthetized and mechanically ventilated patients. The study included 54 patients undergoing non-thoracic surgery with positive pressure mechanical ventilation. The provoked fluid shift comprised 15° Trendelenburg positioning, and fluid responsiveness was defined as a concomitant increase in stroke volume (SV) >10 %. Nexfin blood pressure measurements were performed during supine steady state, Trendelenburg and supine repositioning. Hemodynamic parameters included arterial blood pressure (MAP), CI, PPV and SVV. Trendelenburg positioning did not affect MAP or CI, but induced a decrease in PPV and SVV by 3.3 ± 2.8 and 3.4 ± 2.7 %, respectively. PPV and SVV returned back to baseline values after repositioning of the patient to baseline. Bland-Altman analysis of SVV and PPV showed a bias of -0.3 ± 3.0 % with limits of agreement ranging from -5.6 to 6.2 %. The SVV was more superior in predicting fluid responsiveness (AUC 0.728) than the PVV (AUC 0.636), respectively. The median bias between PPV and SVV was different for patients younger [-1.5 % (-3 to 0)] or older [+2 % (0-4.75)] than 55 years (P < 0.001), while there were no gender differences in the bias between PPV and SVV. The Nexfin monitor adequately reflects alterations in PPV and SVV during a provoked fluid shift, but the level of agreement between PPV and SVV was low. The SVV tended to be superior over PPV or Eadyn in predicting fluid responsiveness in our population.
Kalo, Dorit; Hadas, Ron; Furman, Ori; Ben-Ari, Julius; Maor, Yehoshua; Patterson, Donald G.; Tomey, Cynthia; Roth, Zvi
2015-01-01
We examined acute exposure of Holstein cows to di(2-ethylhexyl) phthalate (DEHP) and its carryover effects on ovarian function and oocyte developmental competence. Synchronized cows were tube-fed with water or 100 mg/kg DEHP per day for 3 days. Blood, urine and milk samples were collected before, during and after DEHP exposure to examine its clearance pattern. Ovarian follicular dynamics was monitored through an entire estrous cycle by ultrasonographic scanning. Follicular fluids were aspirated from the preovulatory follicles on days 0 and 29 of the experiment and analyzed for phthalate metabolites and estradiol concentration. The aspirated follicular fluid was used as maturation medium for in-vitro embryo production. Findings revealed that DEHP impairs the pattern of follicular development, with a prominent effect on dominant follicles. The diameter and growth rate of the first- and second-wave dominant follicles were lower (P < 0.05) in the DEHP-treated group. Estradiol concentration in the follicular fluid was lower in the DEHP-treated group than in controls, and associated with a higher number of follicular pathologies (follicle diameter >25 mm). The pattern of growth and regression of the corpus luteum differed between groups, with a lower volume in the DEHP-treated group (P < 0.05). The follicular fluid aspirated from the DEHP-treated group, but not the controls, contained 23 nM mono(2-ethylhexyl) phthalate. Culturing of cumulus oocyte complexes in the follicular fluid aspirated from DEHP-treated cows reduced the proportion of oocytes progressing to the MII stage, and the proportions of 2- to 4-cell-stage embryos (P < 0.04) and 7-day blastocysts (P < 0.06). The results describe the risk associated with acute exposure to DEHP and its deleterious carryover effects on ovarian function, nuclear maturation and oocyte developmental competence. PMID:26154164
Chomsky, D B; Lang, C C; Rayos, G; Wilson, J R
1997-08-01
Patients with heart failure frequently have elevated intracardiac diastolic pressures but no clinical evidence of excess fluid retention. We speculated that such pressure elevations may indicate subclinical fluid retention and that removal of this fluid could improve exercise intolerance. To test this hypothesis, we studied 10 patients with right atrial pressure > or = 8 mm Hg but without rales, edema, or apparent jugular venous distension. Right-sided heart catheterization was performed, after which patients underwent maximal treadmill cardiopulmonary testing. Patients were then hospitalized and underwent maximal diuresis, after which exercise was repeated. Before diuresis, right atrial pressure averaged 16 +/- 5 mm Hg (+/-standard deviation), pulmonary capillary wedge pressure 30 +/- 6 mm Hg, and peak exercise Vo2 11.2 +/- 2.3 ml/min/ kg. Patients underwent diuresis of 4.5 +/- 2.2 kg over 4 +/- 2 days to a resting right atrial pressure of 6 +/- 4 and wedge pressure of 19 +/- 7 mm Hg. After diuresis, all patients reported overall symptomatic improvement. Maximal exercise duration increased significantly from 9.2 +/- 4.2 to 12.5 +/- 4.7 minutes. At matched peak workloads, significant improvements were also seen in minute ventilation (45 +/- 12 to 35 +/- 9 L/min), lactate levels (42 +/- 16 to 29 +/- 9 mg/dl), and Borg dyspnea scores (15 +/- 3 to 12 +/- 4) (all p < 0.05). Invasive hemodynamic monitoring allows the identification of excess fluid retention in patients with heart failure when there are no clinical signs of fluid overload. Removal of this subclinical excess fluid improves exercise performance and exertional dyspnea.
Lakhal, Karim; Ehrmann, Stephan; Perrotin, Dominique; Wolff, Michel; Boulain, Thierry
2013-11-01
To assess whether invasive and non-invasive blood pressure (BP) monitoring allows the identification of patients who have responded to a fluid challenge, i.e., who have increased their cardiac output (CO). Patients with signs of circulatory failure were prospectively included. Before and after a fluid challenge, CO and the mean of four intra-arterial and oscillometric brachial cuff BP measurements were collected. Fluid responsiveness was defined by an increase in CO ≥10 or ≥15% in case of regular rhythm or arrhythmia, respectively. In 130 patients, the correlation between a fluid-induced increase in pulse pressure (Δ500mlPP) and fluid-induced increase in CO was weak and was similar for invasive and non-invasive measurements of BP: r² = 0.31 and r² = 0.29, respectively (both p < 0.001). For the identification of responders, invasive Δ500mlPP was associated with an area under the receiver-operating curve (AUC) of 0.82 (0.74-0.88), similar (p = 0.80) to that of non-invasive Δ500mlPP [AUC of 0.81 (0.73-0.87)]. Outside large gray zones of inconclusive values (5-23% for invasive Δ500mlPP and 4-35% for non-invasive Δ500mlPP, involving 35 and 48% of patients, respectively), the detection of responsiveness or unresponsiveness to fluid was reliable. Cardiac arrhythmia did not impair the performance of invasive or non-invasive Δ500mlPP. Other BP-derived indices did not outperform Δ500mlPP. As evidenced by large gray zones, BP-derived indices poorly reflected fluid responsiveness. However, in our deeply sedated population, a high increase in invasive pulse pressure (>23%) or even in non-invasive pulse pressure (>35%) reliably detected a response to fluid. In the absence of a marked increase in pulse pressure (<4-5%), a response to fluid was unlikely.
Bromine cycle in subduction zones through in situ Br monitoring in diamond anvil cells
NASA Astrophysics Data System (ADS)
Bureau, Hélène; Foy, Eddy; Raepsaet, Caroline; Somogyi, Andrea; Munsch, Pascal; Simon, Guilhem; Kubsky, Stefan
2010-07-01
The geochemical partitioning of bromine between hydrous haplogranitic melts, initially enriched with respect to Br and aqueous fluids, has been continuously monitored in situ during decompression. Experiments were carried out in diamond anvil cells from 890 °C to room temperature and from 1.7 GPa to room pressure, typically from high P, T conditions corresponding to total miscibility (presence of a supercritical fluid). Br contents were measured in aqueous fluids, hydrous melts and supercritical fluids. Partition coefficients of bromine were characterized at pressure and temperature between fluids, hydrous melts and/or glasses, as appropriate: DBrfluid/melt = (Br) fluid/(Br) melt, ranges from 2.18 to 9.2 ± 0.5 for conditions within the ranges 0.66-1.7 GPa, 590-890 °C; and DBrfluid/glass = (Br) fluid/(Br) glass ranges from 60 to 375 at room conditions. The results suggest that because high pressure melts and fluids are capable of accepting high concentrations of bromine, this element may be efficiently removed from the slab to the mantle source of arc magmas. We show that Br may be highly concentrated in subduction zone magmas and strongly enriched in subduction-related volcanic gases, because its mobility is strongly correlated with that of water during magma degassing. Furthermore, our experimental results suggest that a non negligible part of Br present in the subducted slab may remain in the down-going slab, being transported toward the transition zone. This indicates that the Br cycle in subduction zones is in fact divided in two related but independent parts: (1) a shallower one where recycled Br may leave the slab with a water and silica-bearing "fluid" leading to enriched arc magmas that return Br to the atmosphere. (2) A deeper cycle where Br may be recycled back to the mantle maybe to the transition zone, where it may be present in high pressure water-rich metasomatic fluids.
Joosten, Alexandre; Delaporte, Amelie; Ickx, Brigitte; Touihri, Karim; Stany, Ida; Barvais, Luc; Van Obbergh, Luc; Loi, Patricia; Rinehart, Joseph; Cannesson, Maxime; Van der Linden, Philippe
2018-01-01
The type of fluid and volume regimen given intraoperatively both can impact patient outcome after major surgery. This two-arm, parallel, randomized controlled, double-blind, bi-center superiority study tested the hypothesis that when using closed-loop assisted goal-directed fluid therapy, balanced colloids are associated with fewer postoperative complications compared to balanced crystalloids in patients having major elective abdominal surgery. One hundred and sixty patients were enrolled in the protocol. All patients had maintenance-balanced crystalloid administration of 3 ml · kg · h. A closed-loop system delivered additional 100-ml fluid boluses (patients were randomized to receive either a balanced-crystalloid or colloid solution) according to a predefined goal-directed strategy, using a stroke volume and stroke volume variation monitor. All patients were included in the analysis. The primary outcome was the Post-Operative Morbidity Survey score, a nine-domain scale, at day 2 postsurgery. Secondary outcomes included all postoperative complications. Patients randomized in the colloid group had a lower Post-Operative Morbidity Survey score (median [interquartile range] of 2 [1 to 3] vs. 3 [1 to 4], difference -1 [95% CI, -1 to 0]; P < 0.001) and a lower incidence of postoperative complications. Total volume of fluid administered intraoperatively and net fluid balance were significantly lower in the colloid group. Under our study conditions, a colloid-based goal-directed fluid therapy was associated with fewer postoperative complications than a crystalloid one. This beneficial effect may be related to a lower intraoperative fluid balance when a balanced colloid was used. However, given the study design, the mechanism for the difference cannot be determined with certainty.
Perioperative goal-directed haemodynamic therapy based on flow parameters: a concept in evolution.
Meng, L; Heerdt, P M
2016-12-01
Haemodynamic management incorporating direct or surrogate stroke volume monitoring has experienced a rapid evolution, because of emergence of the "goal-directed therapy" concept and technological developments aimed at providing a parameter leading to the goal. Nonetheless, consensus on both definitions of the ideal "goal" and strategies for achieving it remain elusive. For this review, we first consider basic physiological and patient monitoring factors relevant to the concept of "fluid responsiveness", and then focus upon randomized controlled trials and meta-analyses involving goal-directed haemodynamic therapy based on various flow parameters. Finally, we discuss the current status of noninvasive methods for monitoring fluid responsiveness. © The Author 2016. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Lúcio, Aline D; Vequi-Suplicy, Cíntia C; Fernandez, Roberto M; Lamy, M Teresa
2010-03-01
The highly hydrophobic fluorophore Laurdan (6-dodecanoyl-2-(dimethylaminonaphthalene)) has been widely used as a fluorescent probe to monitor lipid membranes. Actually, it monitors the structure and polarity of the bilayer surface, where its fluorescent moiety is supposed to reside. The present paper discusses the high sensitivity of Laurdan fluorescence through the decomposition of its emission spectrum into two Gaussian bands, which correspond to emissions from two different excited states, one more solvent relaxed than the other. It will be shown that the analysis of the area fraction of each band is more sensitive to bilayer structural changes than the largely used parameter called Generalized Polarization, possibly because the latter does not completely separate the fluorescence emission from the two different excited states of Laurdan. Moreover, it will be shown that this decomposition should be done with the spectrum as a function of energy, and not wavelength. Due to the presence of the two emission bands in Laurdan spectrum, fluorescence anisotropy should be measured around 480 nm, to be able to monitor the fluorescence emission from one excited state only, the solvent relaxed state. Laurdan will be used to monitor the complex structure of the anionic phospholipid DMPG (dimyristoyl phosphatidylglycerol) at different ionic strengths, and the alterations caused on gel and fluid membranes due to the interaction of cationic peptides and cholesterol. Analyzing both the emission spectrum decomposition and anisotropy it was possible to distinguish between effects on the packing and on the hydration of the lipid membrane surface. It could be clearly detected that a more potent analog of the melanotropic hormone alpha-MSH (Ac-Ser(1)-Tyr(2)-Ser(3)-Met(4)-Glu(5)-His(6)-Phe(7)-Arg(8)-Trp(9)-Gly(10)-Lys(11)-Pro(12)-Val(13)-NH(2)) was more effective in rigidifying the bilayer surface of fluid membranes than the hormone, though the hormone significantly decreases the bilayer surface hydration.
Conger, Randall W.
2000-01-01
Between November 1998 and May 1999, geophysical logging was conducted in 29 boreholes at the Crossley Farms Superfund Site, Hereford Township, Berks County, Pa., to determine the fluidproducing zones, fluid-receiving zones, zones of vertical borehole flow, and casing depth. The wells range in depth from 96 to 500 feet below land surface. Gamma logs only were collected in three bedrock wells. The geophysical logging determined the placement of well screens and packers, which allow monitoring and sampling of water-bearing zones in the fractured bedrock so that the horizontal and vertical distribution of contaminated ground water migrating from known sources could be determined. Geophysical logging included collection of caliper, video, fluid-temperature, fluid-resistivity, single-point-resistance, natural-gamma, fluid-flow, and acoustic-televiewer logs. Caliper and video logs were used to locate fractures, joints, and weathered zones. Inflections on fluidtemperature and fluid-resistivity logs indicated possible water-bearing fractures, and flowmeter measurements verified these locations. Single-point-resistance and natural-gamma logs provided information on stratigraphy. After interpretation of geophysical, video logs, and drillers notes, 24 of the wells were reconstructed such that water levels can be monitored and water samples collected from discrete water-bearing fractures in each well.
Aufdenblatten, Christoph Alexander; Altermatt, Stefan
2008-09-01
In the management of severe head injuries, the use of intraventricular catheters for intracranial pressure (ICP) monitoring and the option of cerebrospinal fluid drainage is gold standard. In children and adolescents, the insertion of a cannula in a compressed ventricle in case of elevated intracranial pressure is difficult; therefore, a pressure sensor is placed more often intraparenchymal as an alternative option. In cases of persistent elevated ICP despite maximal brain pressure management, the use of an intraventricular monitoring device with the possibility of cerebrospinal fluid drainage is favourable. We present the method of intracranial catheter placement by means of an electromagnetic navigation technique.
Investigation of the fluidity of biological fluids with a PDDTBN spin probe
NASA Astrophysics Data System (ADS)
Severcan, Feride; Acar, Berrin; Gökalp, Saadet
1997-06-01
The aim of this study is to ascertain whether the electron spin resonance technique using perdeutero-di- t-butyl nitroxide (PDDTBN) as a spin probe is able to monitor relative fluidity changes occurring in body fluids, such as blood and parotid saliva, according to different physiological conditions. The present study reveals that the spin probe PDDTBN is able to monitor the fluidity changes in parotid saliva related to habitual smoking, and in whole blood related to the estradiol level. The rotational correlation time of the spin probe and the local viscosity values of the parotid saliva and blood have been reported.
Mass sensors with mechanical traps for weighing single cells in different fluids.
Weng, Yaochung; Delgado, Francisco Feijó; Son, Sungmin; Burg, Thomas P; Wasserman, Steven C; Manalis, Scott R
2011-12-21
We present two methods by which single cells can be mechanically trapped and continuously monitored within the suspended microchannel resonator (SMR) mass sensor. Since the fluid surrounding the trapped cell can be quickly and completely replaced on demand, our methods are well suited for measuring changes in cell size and growth in response to drugs or other chemical stimuli. We validate our methods by measuring the density of single polystyrene beads and Saccharomyces cerevisiae yeast cells with a precision of approximately 10(-3) g cm(-3), and by monitoring the growth of single mouse lymphoblast cells before and after drug treatment.
Morrissey, M A; Hill, H H
1989-09-01
A simplified procedure was developed for the determination of 2,4-dichlorophenoxyacetic acid (2,4-D) in soils. Soil samples were separated by supercritical fluid chromatography after extraction without derivatization and without the use of column chromatography for cleanup. Interferences in the chromatographic separation were eliminated by using a tunably selective ion mobility detector. An atmospheric pressure ion formed by the free acid was selectively monitored so the detector could monitor 2,4-D in the presence of other electron-capturing compounds. For a randomly chosen soil sample, the level of 2,4-D detected was estimated at 500 ppb.
Wavelength-Agile Optical Sensor for Exhaust Plume and Cryogenic Fluid Interrogation
NASA Technical Reports Server (NTRS)
Sanders, Scott T.; Chiaverini, Martin J.; Gramer, Daniel J.
2004-01-01
Two optical sensors developed in UW-Madison labs were evaluated for their potential to characterize rocket engine exhaust plumes and liquid oxygen (LOX) fluid properties. The plume sensor is based on wavelength-agile absorption spectroscopy A device called a chirped white pulse emitter (CWPE) is used to generate the wavelength agile light, scanning, for example, 1340 - 1560 nm every microsecond. Properties of the gases in the rocket plume (for example temperature and water mole fraction) can be monitored using these wavelength scans. We have performed preliminary tests in static gas cells, a laboratory GOX/GH2 thrust chamber, and a solid-fuel hybrid thrust chamber, and these initial tests demonstrate the potential of the CWPE for monitoring rocket plumes. The LOX sensor uses an alternative to wavelength agile sensing: two independent, fixed-wavelength lasers are combined into a single fiber. One laser is absorbed by LOX and the other not: by monitoring the differential transmission the LOX concentration in cryogenic feed lines can be inferred. The sensor was successful in interrogating static LOX pools in laboratory tests. Even in ice- and bubble-laden cryogenic fluids, LOX concentrations were measured to better than 1% with a 3 microsec time constant.
NASA Astrophysics Data System (ADS)
Abdelghafour, H.; Brondolo, F.; Denchik, N.; Pezard, P. A.
2014-12-01
The controllability of CO2 geological storage can ensure the integrity of storage operations, requiring a precise monitoring of reservoir fluids and properties during injection and over time. In this context, deep saline aquifers offer a large capacity of storing CO2, but the accessibility to long term behavior studies remains limited until now. The Maguelone shallow experimental site located near Montpellier (Languedoc, France) provides such an opportunity for the understanding and accuracy of hydrogeophysical monitoring methods. The geology, petrophysic and hydrology of this site have been studied in details in previous studies, revealing the presence of a thin saline aquifer at 13-16 m depth surrounded by clay-rich materials. The site as a whole provides a natural laboratory to study CO2 injection at field scale, shallow depth, hence reasonable costs. The monitoring setup is composed of a series of hydrogeophysical and geochemical methods offering measurements of fluid pore pressure, electrical resistivity, acoustic velocities as well as pH and fluid properties and chemistry. To assess the response of the reservoir during CO2 injection, all measurements need to be compared to a representative baseline. Long after a series of gas injection experiments at Maguelone, fluctuations overtime of reservoir fluids and properties (such as pore fluid pH) were discovered at steady state, demonstrating the natural variability of the site in terms of biogenic gas (H2S, CH4, CO2) production and transfer. For this, a new resistivity baseline had to be constructed for all observatories. From this, the downhole gas saturation was determined versus depth and time from time-lapse resistivity logs analysed on the basis of other logs and laboratory measurements. The Waxman and Smits model (1968) for electrical properties of sand-clay formations was modified to estimate the gas saturation in 4D, to account for surface conductivity and pore connectivity. High frequency logging and monitoring of electrical properties both, with several measurements per hour and a dm-scale resolution, provide and insight into subsurface dynamics in terms of gas flow and storage, with biogenic gas saturations ranging from 0.1 to 5.0 %. This natural contribution has to be taken into account for upcoming experiments.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sunderman, Jr, F W
1980-08-15
The main research accomplishments during the past three years are summarized. The principle areas of investigation are: 1. embryotoxicity, teratogenicity, and mutagenicity of nickel carbonyl; 2. metabolism, detoxification, and excretion of nickel compounds; 3. studies of nickel carcinogenesis; 4. nickel analysis in body fluids and tissues to monitor occupational exposures; 5. nephrotoxicity of nickel compounds; and 6. hematological effects of nickel compounds. (ACR)
Ultrasonic monitoring of spontaneous imbibition experiments: Acoustic signature of fluid migration
NASA Astrophysics Data System (ADS)
David, Christian; Barnes, Christophe; Desrues, Mathilde; Pimienta, Lucas; Sarout, Joël.; Dautriat, Jérémie
2017-07-01
Capillary rise experiments (spontaneous imbibition tests) were conducted in the laboratory with ultrasonic and X-ray monitoring on the Sherwood sandstone and the Majella grainstone. The aim was to provide a direct comparison between the variation in seismic attributes (amplitude, velocity, spectral content, and energy) and the actual fluid distribution in the rock. Two pairs of ultrasonic P wave sensors located at different heights on a cylindrical rock specimen recorded every 5 s the waveforms when capillary forces make water rise up into the rock from the bottom in contact with a water tank. Simultaneously, computerized tomography scan images of a vertical cross section were also recorded. Two important results were found. (i) The amplitude of the first P wave arrival is impacted by the upward moving fluid front before the P wave velocity is, while the fluid front has not yet reached the sensors level. In contrast, the P wave velocity decreases when the fluid front reaches the Fresnel clearance zone. The spectral analysis of the waveforms shows that the peak frequency amplitude is continuously decreasing without noticeable frequency shift. (ii) A methodology based on the calculation of the analytical signal and instantaneous phase was designed to decompose each waveform into discrete wavelets associated with direct or reflected waves. The energy carried by the wavelets is very sensitive to the fluid substitution process: the coda wavelets related to reflections on the bottom end face of the specimen are impacted as soon as imbibition starts and can be used as a precursor for the arriving fluid.
Hu, Shi-Jie; Li, Xia; Xu, Can-Hua; Wang, Bing; Yang, Bin; Tang, Meng-Xing; Dong, Xiu-Zhen; Fei, Zhou; Shi, Xue-Tao
2014-01-01
Objective Variations of conductive fluid content in brain tissue (e.g. cerebral edema) change tissue impedance and can potentially be measured by Electrical Impedance Tomography (EIT), an emerging medical imaging technique. The objective of this work is to establish the feasibility of using EIT as an imaging tool for monitoring brain fluid content. Design a prospective study. Setting In this study EIT was used, for the first time, to monitor variations in cerebral fluid content in a clinical model with patients undergoing clinical dehydration treatment. The EIT system was developed in house and its imaging sensitivity and spatial resolution were evaluated on a saline-filled tank. Patients 23 patients with brain edema. Interventions The patients were continuously imaged by EIT for two hours after initiation of dehydration treatment using 0.5 g/kg intravenous infusion of mannitol for 20 minutes. Measurement and Main Results Overall impedance across the brain increased significantly before and after mannitol dehydration treatment (p = 0.0027). Of the all 23 patients, 14 showed high-level impedance increase and maintained this around 4 hours after the dehydration treatment whereas the other 9 also showed great impedance gain during the treatment but it gradually decreased after the treatment. Further analysis of the regions of interest in the EIT images revealed that diseased regions, identified on corresponding CT images, showed significantly less impedance changes than normal regions during the monitoring period, indicating variations in different patients' responses to such treatment. Conclusions EIT shows potential promise as an imaging tool for real-time and non-invasive monitoring of brain edema patients. PMID:25474474
Peters, Johanna; Teske, Andreas; Taute, Wolfgang; Döscher, Claas; Höft, Michael; Knöchel, Reinhard; Breitkreutz, Jörg
2018-02-15
The trend towards continuous manufacturing in the pharmaceutical industry is associated with an increasing demand for advanced control strategies. It is a mandatory requirement to obtain reliable real-time information on critical quality attributes (CQA) during every process step as the decision on diversion of material needs to be performed fast and automatically. Where possible, production equipment should provide redundant systems for in-process control (IPC) measurements to ensure continuous process monitoring even if one of the systems is not available. In this paper, two methods for real-time monitoring of granule moisture in a semi-continuous fluid-bed drying unit are compared. While near-infrared (NIR) spectroscopy has already proven to be a suitable process analytical technology (PAT) tool for moisture measurements in fluid-bed applications, microwave resonance technology (MRT) showed difficulties to monitor moistures above 8% until recently. The results indicate, that the newly developed MRT sensor operating at four resonances is capable to compete with NIR spectroscopy. While NIR spectra were preprocessed by mean centering and first derivative before application of partial least squares (PLS) regression to build predictive models (RMSEP = 0.20%), microwave moisture values of two resonances sufficed to build a statistically close multiple linear regression (MLR) model (RMSEP = 0.07%) for moisture prediction. Thereby, it could be verified that moisture monitoring by MRT sensor systems could be a valuable alternative to NIR spectroscopy or could be used as a redundant system providing great ease of application. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Tiwari, Vidhu S.; Kalluru, Rajamohan R.; Yueh, Fang Y.; Singh, Jagdish P.; St. Cyr, William; Khijwania, Sunil K.
2007-06-01
A spontaneous Raman scattering optical fiber sensor was developed for a specific need of the National Aeronautics and Space Administration (NASA) for long-term detection and monitoring of the purity of liquid oxygen (LO2) in the oxidizer feed line during ground testing of rocket engines. The Raman peak intensity ratios for liquid nitrogen (LN2) and LO2 with varied weight ratios (LN2/LO2) were analyzed for their applicability to impurity sensing. The study of the sensor performance with different excitation light sources has helped to design a miniaturized, cost-effective system for this application. The optimal system response time of this miniaturized sensor for LN2/LO2 measurement was found to be in the range of a few seconds. It will need to be further reduced to the millisecond range for real-time, quantitative monitoring of the quality of cryogenic fluids in a harsh envioronment.
NASA Astrophysics Data System (ADS)
Yokoyama, Moe; Yamada, Kenji; Nishimura, Takahiro; Kido, Michiko; Jeong, Hieyong; Ohno, Yuko
2015-03-01
Therapeutic drug monitoring (TDM) contributes to safe and effective pharmacotherapy in clinical fields. A simple, rapid, low-cost, and minimally-invasive drug measurement method attracts much interest for point-of-care TDM. Tear fluids can be collected minimally-invasively compared to blood sampling and there is a correlation between a drug concentration in tears and that in bloods. Surface enhanced Raman spectroscopy (SERS) with paper-based substrate is useful for point-of-care TDM owing to inexpensiveness and high-sensitivity. Paper is also a safe tear collection tool. Then we are studying on a paper-based SERS of tear specimen for point-of-care TDM. In this paper, to improve sensitivity in measuring drug concentration in tear fluids, we fabricated a SERS substrate by coating gold nano-rods on a paper substrate and evaluated whether the fabricated substrate can enhance Raman scattering. Sodium phenobarbital (PB), an anti-convulsant agent, was used as a target. In experiment, the fabricated substrate indicated the lower detection limit of PB in a solution than a plain paper substrate. This result showed the potential of the paper based SERS substrate to measure drug concentration in tears simply and inexpensively.
Modeling and Measurement of Correlation between Blood and Interstitial Glucose Changes
Shi, Ting; Li, Dachao; Li, Guoqing; Zhang, Yiming; Xu, Kexin; Lu, Luo
2016-01-01
One of the most effective methods for continuous blood glucose monitoring is to continuously measure glucose in the interstitial fluid (ISF). However, multiple physiological factors can modulate glucose concentrations and affect the lag phase between blood and ISF glucose changes. This study aims to develop a compensatory tool for measuring the delay in ISF glucose variations in reference to blood glucose changes. A theoretical model was developed based on biophysics and physiology of glucose transport in the microcirculation system. Blood and interstitial fluid glucose changes were measured in mice and rats by fluorescent and isotope methods, respectively. Computer simulation mimicked curves were fitted with data resulting from fluorescent measurements of mice and isotope measurements of rats, indicating that there were lag times for ISF glucose changes. It also showed that there was a required diffusion distance for glucose to travel from center of capillaries to interstitial space in both mouse and rat models. We conclude that it is feasible with the developed model to continuously monitor dynamic changes of blood glucose concentration through measuring glucose changes in ISF with high accuracy, which requires correct parameters for determining and compensating for the delay time of glucose changes in ISF. PMID:27239479
Cvijić, Marta; Zižek, David; Antolič, Bor; Zupan, Igor
2013-01-01
The intrathoracic impedance monitor system measures impedance between the device case and the right ventricular coil and reflects intrathoracic fluid status. It is used to detect early volume overload in patients with chronic heart failure. We report a case of inappropriate activation of the intrathoracic impedance monitor alarm in a patient with epidermoid lung cancer and pleural carcinosis.
Approach to the critically ill camelid.
Bedenice, Daniela
2009-07-01
The estimation of fluid deficits in camelids is challenging. However, early recognition and treatment of shock and hypovolemia is instrumental to improve morbidity and mortality of critically ill camelids. Early goal-directed fluid therapy requires specific knowledge of clinical indicators of hypovolemia and assessment of resuscitation endpoints, but may significantly enhance the understanding, monitoring, and safety of intravenous fluid therapy in South American camelids (SAC). It is important to recognize that over-aggressive fluid resuscitation is just as detrimental as under resuscitation. Nonetheless, a protocol of conservative fluid management is often indicated in the treatment of camelids with pulmonary inflammation, to counteract edema formation. The early recognition of lung dysfunction is often based on advanced diagnostic techniques, including arterial blood gas analysis, diagnostic imaging, and noninvasive pulmonary function testing.
NASA Astrophysics Data System (ADS)
Noh, K.; Jeong, S.; Seol, S. J.; Byun, J.; Kwon, T.
2015-12-01
Man-made carbon dioxide (CO2) released into the atmosphere is a significant contributor to the greenhouse gas effect and related global warming. Sequestration of CO2 into saline aquifers has been proposed as one of the most practical options of all geological sequestration possibilities. During CO2 geological sequestration, monitoring is indispensable to delineate the change of CO2 saturation and migration of CO2 in the subsurface. Especially, monitoring of CO2 saturation in aquifers provides useful information for determining amount of injected CO2. Seismic inversion can provide the migration of CO2 plume with high resolution because velocity is reduced when CO2 replaces the pore fluid during CO2 injection. However, the estimation of CO2 saturation using the seismic method is difficult due to the lower sensitivity of the velocity to the saturation when the CO2 saturation up to 20%. On the other hand, marine controlled-source EM (mCSEM) inversion is sensitive to the resistivity changes resulting from variations in CO2 saturation, even though it has poor resolution than seismic method. In this study, we proposed an effective CO2 sequestration monitoring method using joint inversion of seismic and mCSEM data based on a cross-gradient constraint. The method was tested with realistic CO2 injection models in a deep brine aquifer beneath a shallow sea which is selected with consideration for the access convenience for the installation of source and receiver and an environmental safety. Resistivity images of CO2 plume by the proposed method for different CO2 injection stages have been significantly improved over those obtained from individual EM inversion. In addition, we could estimate a reliable CO2 saturation by rock physics model (RPM) using the P-wave velocity and the improved resistivity. The proposed method is a basis of three-dimensional estimation of reservoir parameters such as porosity and fluid saturation, and the method can be also applied for detecting a reservoir and calculating the accurate oil and gas reserves.
Neutron activation analysis system
Taylor, M.C.; Rhodes, J.R.
1973-12-25
A neutron activation analysis system for monitoring a generally fluid media, such as slurries, solutions, and fluidized powders, including two separate conduit loops for circulating fluid samples within the range of radiation sources and detectors is described. Associated with the first loop is a neutron source that emits s high flux of slow and thermal neutrons. The second loop employs a fast neutron source, the flux from which is substantially free of thermal neutrons. Adjacent to both loops are gamma counters for spectrographic determination of the fluid constituents. Other gsmma sources and detectors are arranged across a portion of each loop for deterMining the fluid density. (Official Gazette)
Baghel, Kavita; Raj, Saloni; Awasthi, Induja; Gupta, Vishal; Chandra, Abhijit; Srivastava, Rajeshwar Nath
2013-01-01
Background: An alternative to intravenous is nasogastric fluid administration through normal functioning gut. Though not common, this practice has significance in mass causalities and elective situations. Aim: The study was designed to compare nasogastric and intravenous fluid resuscitation in malignant obstructive jaundice (OJ) and their effect on endotoxemia. Materials and Methods: Sixty patients with malignant OJ undergoing endoscopic biliary drainage were randomized into two groups. A total of 4 l of fluid (Ringer's lactate) was administered to Group A through nasogastric tube and to Group B through intravenous route for 48 h. Vital parameters, serum bilirubin, serum creatinine, creatinine clearance rate, electrolytes, and endotoxemia were monitored. Results: Significant improvement in blood pressure (Group A, P = 0.014; Group B, P = 0.020) and significant decrease in serum bilirubin level (Group A, P = 0.001; Group B, P > 0.0001) was observed in both groups after resuscitation. Significantly decreased (P = 0.036) post hydration endotoxin level was observed in Group A as compared to Group B. Febrile events were significantly higher (P = 0.023) in Group B as compared to Group A (6 vs 0). Electrolyte abnormalities were found more in Group B, however statistically insignificant. Conclusion: In OJ patient undergoing biliary drainage, preoperative fluid resuscitation through nasogastric tube may be helpful in reducing postoperative septic complications and endotoxemia. PMID:24251269
NASA Astrophysics Data System (ADS)
Vanorio, T.
2016-12-01
Monitoring chemo-mechanical processes geophysically — e.g., fluid disposal or storage, thermal and chemical stimulation of reservoirs, or natural fluids simply entering a new system in the subsurface— raises numerous concerns because of the likelihood of fluid-rock chemical interactions and our limited ability to decipher the geophysical signature of coupled processes. One of the missing links is coupling the evolution of porosity, permeability, and velocity of rocks together with reactive transport, since rocks deform and their microstructure evolves, as a result of chemical reactions under stress. This study describes recent advances in rock-physics experiments to understand the effects of dissolution-induced compaction on acoustic velocity, porosity, and permeability. Data observation includes time-lapse experiments and imaging tracking transport and elastic properties, the rock microstructure, and the pH and chemical composition of the fluid permeating the rock. Results show that the removal of high surface area, mineral phases such as microcrystalline calcite and clay appears to be mostly responsible for dissolution-induced compaction. Nevertheless, it is the original rock microstructure and its response to stress that ultimately defines how solution-transfer and rock compaction feed back upon each other. This work has a dual aim: understanding the mechanisms underlying permanent modifications to the rock microstructure and providing a richer set of experimental information to inform the formulation of new simulations and rock modeling.
Thompson, Kristin E; Korbmacher, Jonas P; Hecht, Elena; Hobi, Nina; Wittekindt, Oliver H; Dietl, Paul; Kranz, Christine; Frick, Manfred
2013-04-01
Two fundamental mechanisms within alveoli are essential for lung function: regulated fluid transport and secretion of surfactant. Surfactant is secreted via exocytosis of lamellar bodies (LBs) in alveolar type II (ATII) cells. We recently reported that LB exocytosis results in fusion-activated cation entry (FACE) via P2X₄ receptors on LBs. We propose that FACE, in addition to facilitating surfactant secretion, modulates alveolar fluid transport. Correlative fluorescence and atomic force microscopy revealed that FACE-dependent water influx correlated with individual fusion events in rat primary ATII cells. Moreover, ATII cell monolayers grown at air-liquid interface exhibited increases in short-circuit current (Isc) on stimulation with ATP or UTP. Both are potent agonists for LB exocytosis, but only ATP activates FACE. ATP, not UTP, elicited additional fusion-dependent increases in Isc. Overexpressing dominant-negative P2X₄ abrogated this effect by ∼50%, whereas potentiating P2X4 lead to ∼80% increase in Isc. Finally, we monitored changes in alveolar surface liquid (ASL) on ATII monolayers by confocal microscopy. Only stimulation with ATP, not UTP, led to a significant, fusion-dependent, 20% decrease in ASL, indicating apical-to-basolateral fluid transport across ATII monolayers. Our data support the first direct link between LB exocytosis, regulation of surfactant secretion, and transalveolar fluid resorption via FACE.
CO2 plume management in saline reservoir sequestration
Frailey, S.M.; Finley, R.J.
2011-01-01
A significant difference between injecting CO2 into saline aquifers for sequestration and injecting fluids into oil reservoirs or natural gas into aquifer storage reservoirs is the availability and use of other production and injection wells surrounding the primary injection well(s). Of major concern for CO2 sequestration using a single well is the distribution of pressure and CO2 saturation within the injection zone. Pressure is of concern with regards to caprock integrity and potential migration of brine or CO2 outside of the injection zone, while CO2 saturation is of interest for storage rights and displacement efficiency. For oil reservoirs, the presence of additional wells is intended to maximize oil recovery by injecting CO2 into the same hydraulic flow units from which the producing wells are withdrawing fluids. Completing injectors and producers in the same flow unit increases CO2 throughput, maximizes oil displacement efficiency, and controls pressure buildup. Additional injectors may surround the CO2 injection well and oil production wells in order to provide external pressure to these wells to prevent the injected CO2 from migrating from the pattern between two of the producing wells. Natural gas storage practices are similar in that to reduce the amount of "cushion" gas and increase the amount of cycled or working gas, edge wells may be used for withdrawal of gas and center wells used for gas injection. This reduces loss of gas to the formation via residual trapping far from the injection well. Moreover, this maximizes the natural gas storage efficiency between the injection and production wells and reduces the areal extent of the natural gas plume. Proposed U.S. EPA regulations include monitoring pressure and suggest the "plume" may be defined by pressure in addition to the CO2 saturated area. For pressure monitoring, it seems that this can only be accomplished by injection zone monitoring wells. For pressure, these wells would not need to be very close to the injection well, compared to monitoring wells intended to measure CO2 saturation via fluid sampling or cased-hole well logs. If pressure monitoring wells become mandated, these wells could be used for managing the CO2 saturation and aquifer pressure distribution. To understand the relevance and effectiveness of producing and injecting brine to improve storage efficiency, direct the plume to specific pore space, and redistribute the pressure, numerical models of CO2 injection into aquifers are used. Simulated cases include various aquifer properties at a single well site and varying the number and location of surrounding wells for plume management. Strategies in terms of completion intervals can be developed to effectively contact more vertical pore space in relatively thicker geologic formations. Inter-site plume management (or cooperative) wells for the purpose of pressure monitoring and plume management may become the responsibility of a consortium of operators or a government entity, not individual sequestration site operators. ?? 2011 Published by Elsevier Ltd.
NASA Astrophysics Data System (ADS)
Hachay, Olga; Khachay, Andrey; Khachay, Oleg
2016-04-01
The processes of oil extraction from deposit are linked with the movement of multi-phase multi-component media, which are characterized by non-equilibrium and non-linear rheological features. The real behavior of layered systems is defined by the complexity of the rheology of moving fluids and the morphology structure of the porous medium, and also by the great variety of interactions between the fluid and the porous medium [Hasanov and Bulgakova, 2003]. It is necessary to take into account these features in order to informatively describe the filtration processes due to the non-linearity, non-equilibrium and heterogeneity that are features of real systems. In this way, new synergetic events can be revealed (namely, a loss of stability when oscillations occur, and the formation of ordered structures). This allows us to suggest new methods for the control and management of complicated natural systems that are constructed on account of these phenomena. Thus the layered system, from which it is necessary to extract the oil, is a complicated dynamical hierarchical system. A comparison is provided of non-equilibrium effects of the influence of independent hydrodynamic and electromagnetic induction on an oil layer and the medium which it surrounds. It is known that by drainage and steeping the hysteresis effect on curves of the relative phase permeability in dependence on the porous medium's water saturation in some cycles of influence (drainage-steep-drainage) is observed. Using the earlier developed 3D method of induction electromagnetic frequency geometric monitoring, we showed the possibility of defining the physical and structural features of a hierarchical oil layer structure and estimating the water saturation from crack inclusions. This effect allows managing the process of drainage and steeping the oil out of the layer by water displacement. An algorithm was constructed for 2D modeling of sound diffraction on a porous fluid-saturated intrusion of a hierarchical structure located in layer number J of an N-layered elastic medium. The algorithm developed for modeling, and the method of mapping and monitoring of heterogenic highly complicated two-phase medium can be used for managing viscous oil extraction in mining conditions and light oil in sub-horizontal boreholes. The demand for effective economic parameters and fuller extraction of oil and gas from deposits dictates the necessity of developing new geotechnology based on the fundamental achievements in the area of geophysics and geomechanics
Telemetric implantable pressure sensor for short- and long-term monitoring of intracranial pressure.
Frischholz, M; Sarmento, L; Wenzel, M; Aquilina, K; Edwards, R; Coakham, H B
2007-01-01
Patients with hydrocephalus, idiopathic intracranial hypertension and head injury frequently require monitoring of intracranial pressure (ICP) and may need repeated episodes of monitoring months or years apart. The gold standard for measurement of ICP remains the external ventricular catheter. This is a fluid-filled catheter transducer system that allows regular recalibration and correction of zero drift by its position relative to a fixed anatomical reference. It also allows drainage of cerebrospinal fluid (CSF), providing a means of lowering the ICP. Several catheter tip transducer systems are currently in clinical use, including using strain gauges or fiber-optical pressure sensing techniques. In these devices, zero drift and calibration cannot be checked in vivo. All the ICP monitoring devices in current clinical use require a physical connection between the brain and the external environment. This is a source of infection and limits the duration of monitoring. A number of telemetric monitoring devices, in which data is in some way transmitted transcutaneously, have been developed over the last twenty years, but significant technical problems have precluded their use in routine clinical practice. All current ICP monitors are temporary percutaneous implanted devices. Placement of these devices carries significant morbidity, particularly infection. Patients undergoing repeated monitoring require multiple surgical procedures. Apart from decreasing the risk of infection in patients with severe head injury, the clinical value of an accurate telemetric ICP monitoring system which maintains its reliability over a long period of implantation is high.
Guidelines for European workplace drug testing in oral fluid.
Cooper, Gail; Moore, Christine; George, Claire; Pichini, Simona
2011-05-01
Over the past decade, oral fluid has established itself as a robust testing matrix for monitoring drug use or misuse. Commercially available collection devices provide opportunities to collect and test oral fluid by the roadside and near-patient testing with both clinical and criminal justice applications. One of the main advantages of oral fluid relates to the collection of the matrix which is non-invasive, simple, and can be carried out under direct observation making it ideal for workplace drug testing. Laboratories offering legally defensible oral fluid workplace drug testing must adhere to national and international quality standards (ISO/IEC 17025); however, these standards do not address issues specific to oral fluid testing. The European Workplace Drug Testing Society (EWDTS) recognizes the importance of providing best practice guidelines to organizations offering testing and those choosing to use oral fluid drug testing to test their employees. The aim of this paper is to present the EWDTS guidelines for oral fluid workplace drug testing. Copyright © 2011 John Wiley & Sons, Ltd.
Validation of the solidifying soil process using laser-induced breakdown spectroscopy
NASA Astrophysics Data System (ADS)
Lin, Zhao-Xiang; Liu, Lin-Mei; Liu, Lu-Wen
2016-09-01
Although an Ionic Soil Stabilizer (ISS) has been widely used in landslide control, it is desirable to effectively monitor the stabilization process. With the application of laser-induced breakdown spectroscopy (LIBS), the ion contents of K, Ca, Na, Mg, Al, and Si in the permeable fluid are detected after the solidified soil samples have been permeated. The processes of the Ca ion exchange are analyzed at pressures of 2 and 3 atm, and it was determined that the cation exchanged faster as the pressure increased. The Ca ion exchanges were monitored for different stabilizer mixtures, and it was found that a ratio of 1:200 of ISS to soil is most effective. The investigated plasticity and liquidity indexes also showed that the 1:200 ratio delivers the best performance. The research work indicates that it is possible to evaluate the engineering performances of soil solidified by ISS in real time and online by LIBS.
Wåhlén, K; Fornander, L; Olausson, P; Ydreborg, K; Flodin, U; Graff, P; Lindahl, M; Ghafouri, B
2016-10-01
Upper airway irritation is common among individuals working in moldy and damp buildings. The aim of this study was to investigate effects on the protein composition of the nasal lining fluid. The prevalence of symptoms in relation to work environment was examined in 37 individuals working in two damp buildings. Microbial growth was confirmed in one of the buildings. Nasal lavage fluid was collected from 29 of the exposed subjects and 13 controls, not working in a damp building. Protein profiles were investigated with a proteomic approach and evaluated by multivariate statistical models. Subjects from both workplaces reported upper airway and ocular symptoms. Based on protein profiles, symptomatic subjects in the two workplaces were discriminated from each other and separated from healthy controls. The groups differed in proteins involved in inflammation and host defense. Measurements of innate immunity proteins showed a significant increase in protein S100-A8 and decrease in SPLUNC1 in subjects from one workplace, while alpha-1-antitrypsin was elevated in subjects from the other workplace, compared with healthy controls. The results show that protein profiles in nasal lavage fluid can be used to monitor airway mucosal effects in personnel working in damp buildings and indicate that the profile may be separated when the dampness is associated with the presence of molds. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Fluid Therapy Management in Hospitalized Patients: Results From a Cross-sectional Study.
Brugnolli, Anna; Canzan, Federica; Bevilacqua, Anita; Marognolli, Oliva; Verlato, Giuseppe; Vincenzi, Silvia; Ambrosi, Elisa
2017-02-01
Intravenous (IV) fluid therapy is widely used in hospitalized patients. It has been internationally studied in surgical patients, but little attention to date has been dedicated to medical patients within the Italian context. The aims of the present study were to describe the prevalence of fluid therapy and associated factors among Italian patients admitted to medical and surgical units, describe the methods used to manage fluid therapy, and analyze the monitoring of patients by clinical staff. In this cross-sectional study of 7 hospitals in northern Italy, data on individual and monitoring variables were collected, and their associations with in-hospital fluid therapy were analyzed by using logistic regression analysis. Patients aged ≥18 years who were admitted to medical and surgical units were included. Patients who received at least 500 mL of continuous fluids were included in the fluid therapy group. In total, 785 (median age, 72 years; women, 52%) patients were included in the study, and 293 (37.3%) received fluid therapy. Maintenance was the most frequent reason for prescribing IV fluid therapy (59%). The mean (SD) volume delivered was 1177 (624) mL/d, and the highest volume was infused for replacement therapy (1660 [931] mL/d). The mean volume infused was 19.55 (13) mL/kg/d. The most commonly used fluid solutions were 0.9% sodium chloride (65.7%) and balanced crystalloid without glucose (32.9%). The proportion of patients assessed for urine output (52.6% vs 36.8%; P < 0.001), serum electrolyte concentrations (74.4% vs 65.0%; P = 0.005), and renal function (70.0% vs 58.7%; P = 0.002) was significantly higher in patients who did receive fluid therapy versus those who did not. In contrast, the use of weight and fluid assessments was not significantly different between the 2 groups (P = 0.216 and 0.256, respectively). Patients admitted for gastrointestinal disorders (odds ratio [OR], 3.5 [95% CI, 1.8-7.05) and for fluid/electrolyte imbalances (OR, 3.35 [95% CI, 1.06-10.52) were more likely to receive fluids. However, the likelihood of receiving fluids was lower for patients admitted to a surgical unit (OR, 0.36 [95% CI, 0.22-0.59]) and with cardiovascular diseases (OR, 0.37 [95% CI, 0.17-0.79). Only one third of the study patients received fluid therapy. Crystalloid fluids, are the fluids of choice for maintaining plasma volume. During fluid therapy, measurement of the serum electrolyte concentrations, renal function, and urine output was largely used while weight and fluid balance were rarely assessed. Copyright © 2017 Elsevier HS Journals, Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Hoehler, T.; Som, S.; Schrenk, M.; McCollom, T.; Cardace, D.
2016-01-01
Metabolic potential and activity associated with hydrogen and carbon monoxide were characterized in fluids sampled from the the Coast Range Ophiolite Microbial Observatory (CROMO). CROMO consists of two clusters of science-dedicated wells drilled to varying depths up to 35m in the actively serpentinizing, Jurassic-age Coast Range Ophiolite of Northern California, along with a suite of pre-existing monitoring wells at the same site. Consistent with the fluid chemistry observed in other serpentinizing systems, CROMO fluids are highly alkaline, with pH up to 12.5, high in methane, with concentrations up 1600 micromolar, and low in dissolved inorganic carbon (DIC), with concentrations of 10's to 100's of micromolar. CROMO is conspicuous for fluid H2 concentrations that are consistently sub-micromolar, orders of magnitude lower than is typical of other systems. However, higher H2 concentrations (10's -100's of micromolar) at an earlier stage of fluid chemical evolution are predicted by, or consistent with: thermodynamic models for fluid chemistry based on parent rock composition equivalent to local peridotite and with water:rock ratio constrained by observed pH; the presence of magnetite at several wt% in CROMO drill cores; and concentrations of formate and carbon monoxide that would require elevated H2 if formed in equilibrium with H2 and DIC. Calculated Gibbs energy changes for reaction of H2 and CO in each of several metabolisms, across the range of fluid composition encompassed by the CROMO wells, range from bioenergetically feasible (capable of driving ATP synthesis) to thermodynamically unfavorable. Active consumption relative to killed controls was observed for both CO and H2 during incubation of fluids from the pre-existing monitoring wells; in incubations of freshly cored solids, consumption was only observed in one sample set (corresponding to the lowest pH) out of three. The specific metabolisms by which H2 and CO are consumed remain to be determined.
Wearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics
Kim, Joohee; Kim, Minji; Lee, Mi-Sun; Kim, Kukjoo; Ji, Sangyoon; Kim, Yun-Tae; Park, Jihun; Na, Kyungmin; Bae, Kwi-Hyun; Kyun Kim, Hong; Bien, Franklin; Young Lee, Chang; Park, Jang-Ung
2017-01-01
Wearable contact lenses which can monitor physiological parameters have attracted substantial interests due to the capability of direct detection of biomarkers contained in body fluids. However, previously reported contact lens sensors can only monitor a single analyte at a time. Furthermore, such ocular contact lenses generally obstruct the field of vision of the subject. Here, we developed a multifunctional contact lens sensor that alleviates some of these limitations since it was developed on an actual ocular contact lens. It was also designed to monitor glucose within tears, as well as intraocular pressure using the resistance and capacitance of the electronic device. Furthermore, in-vivo and in-vitro tests using a live rabbit and bovine eyeball demonstrated its reliable operation. Our developed contact lens sensor can measure the glucose level in tear fluid and intraocular pressure simultaneously but yet independently based on different electrical responses. PMID:28447604
Wearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics.
Kim, Joohee; Kim, Minji; Lee, Mi-Sun; Kim, Kukjoo; Ji, Sangyoon; Kim, Yun-Tae; Park, Jihun; Na, Kyungmin; Bae, Kwi-Hyun; Kyun Kim, Hong; Bien, Franklin; Young Lee, Chang; Park, Jang-Ung
2017-04-27
Wearable contact lenses which can monitor physiological parameters have attracted substantial interests due to the capability of direct detection of biomarkers contained in body fluids. However, previously reported contact lens sensors can only monitor a single analyte at a time. Furthermore, such ocular contact lenses generally obstruct the field of vision of the subject. Here, we developed a multifunctional contact lens sensor that alleviates some of these limitations since it was developed on an actual ocular contact lens. It was also designed to monitor glucose within tears, as well as intraocular pressure using the resistance and capacitance of the electronic device. Furthermore, in-vivo and in-vitro tests using a live rabbit and bovine eyeball demonstrated its reliable operation. Our developed contact lens sensor can measure the glucose level in tear fluid and intraocular pressure simultaneously but yet independently based on different electrical responses.
NASA Astrophysics Data System (ADS)
Liu, Lina; Long, Pin; Liu, Tiegen
2004-11-01
Timely, accurate and reliable pressure information about how the reservoir is performing is an important component to optimizing oil yield and production rates. This paper reviews the use of fiber optical pressure sensor for downhole monitoring in the oil industry. Several types of pressure transducer with different characteristics have been introduced. Due to their multiplexing capabilities and versatility ,the use of Bragg grating sensors appears to be particularly suited for this application. A sensor for accurate and long term fluid pressure monitoring based on optical fiber Bragg gratings(FBGs) is developed. The sensor converts fluid pressure into optical fiber strain by means of a mechanical transducer to enhance its sensitivity to pressure. It can also implement distributed or multiplexed sensing. The sensor operation is studied at pressure up to 100 Mpa(1000bar) and the tested temperature to ~175°. It is possible to be used in the well.
Wearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics
NASA Astrophysics Data System (ADS)
Kim, Joohee; Kim, Minji; Lee, Mi-Sun; Kim, Kukjoo; Ji, Sangyoon; Kim, Yun-Tae; Park, Jihun; Na, Kyungmin; Bae, Kwi-Hyun; Kyun Kim, Hong; Bien, Franklin; Young Lee, Chang; Park, Jang-Ung
2017-04-01
Wearable contact lenses which can monitor physiological parameters have attracted substantial interests due to the capability of direct detection of biomarkers contained in body fluids. However, previously reported contact lens sensors can only monitor a single analyte at a time. Furthermore, such ocular contact lenses generally obstruct the field of vision of the subject. Here, we developed a multifunctional contact lens sensor that alleviates some of these limitations since it was developed on an actual ocular contact lens. It was also designed to monitor glucose within tears, as well as intraocular pressure using the resistance and capacitance of the electronic device. Furthermore, in-vivo and in-vitro tests using a live rabbit and bovine eyeball demonstrated its reliable operation. Our developed contact lens sensor can measure the glucose level in tear fluid and intraocular pressure simultaneously but yet independently based on different electrical responses.
Actively controlling coolant-cooled cold plate configuration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chainer, Timothy J.; Parida, Pritish R.
A method is provided to facilitate active control of thermal and fluid dynamic performance of a coolant-cooled cold plate. The method includes: monitoring a variable associated with at least one of the coolant-cooled cold plate or one or more electronic components being cooled by the cold plate; and dynamically varying, based on the monitored variable, a physical configuration of the cold plate. By dynamically varying the physical configuration, the thermal and fluid dynamic performance of the cold plate are adjusted to, for example, optimally cool the one or more electronic components, and at the same time, reduce cooling power consumptionmore » used in cooling the electronic component(s). The physical configuration can be adjusted by providing one or more adjustable plates within the coolant-cooled cold plate, the positioning of which may be adjusted based on the monitored variable.« less
Detection time for THC in oral fluid after frequent cannabis smoking.
Andås, Hilde T; Krabseth, Hege-Merete; Enger, Asle; Marcussen, Bjarne N; Haneborg, An-Magritt; Christophersen, Asbjørg S; Vindenes, Vigdis; Øiestad, Elisabeth L
2014-12-01
The use of oral fluid for detecting drugs of abuse has become increasingly more frequent. Few studies have, however, investigated the detection times for drugs of abuse in oral fluid, compared with that of in urine or in blood. Cannabis is the world's most widely used drug of abuse, and the detection times for cannabis, in different types of matrixes, are therefore important information to the laboratories or institutions performing and evaluating drugs of abuse analyses. It is well known that frequent use of high dosages of cannabis, for longer periods of time, might lead to prolonged detection times for THC-COOH in urine. Cannabis intake is detected in oral fluid as THC, and a positive finding is considered to be a result of recent smoking, although some studies have already reported longer detection times. The aim of this study was to investigate the detection time for THC in oral fluid, collected from drug addicts admitted for detoxification. Findings in oral fluid were compared with findings in urine, among 26 patients admitted to a closed detoxification unit. The study, being the first in doing so, describes the concentration-time profiles for THC in oral fluid among chronic cannabis users, during monitored abstinence, using the Intercept collection kit. The study also includes the concentration-time profiles for creatinine-corrected THC-COOH ratios in urine samples, included to monitor for the possibility of new intakes. THC was detected in oral fluid collected from 11 of the 26 patients in the study. The elimination curves for THC in oral fluid revealed that negative samples could be interspersed among positive samples several days after cessation, whereas the THC-COOH concentrations in urine were decreasing. THC was, in this study, detected in oral fluid for up to 8 days after admission. The study shows that frequent use of high dosages of cannabis may lead to prolonged detection times, and that positive samples can be interspersed among negative samples. These results are of great importance when THC results from oral fluid analyses are to be interpreted.
Microbial life in cold, hydrologically active oceanic crustal fluids
NASA Astrophysics Data System (ADS)
Meyer, J. L.; Jaekel, U.; Girguis, P. R.; Glazer, B. T.; Huber, J. A.
2012-12-01
It is estimated that at least half of Earth's microbial biomass is found in the deep subsurface, yet very little is known about the diversity and functional roles of these microbial communities due to the limited accessibility of subseafloor samples. Ocean crustal fluids, which may have a profound impact on global nutrient cycles given the large volumes of water moving through the crustal aquifer, are particularly difficult to sample. Access to uncontaminated ocean crustal fluids is possible with CORK (Circulation Obviation Retrofit Kit) observatories, installed through the Integrated Ocean Drilling Program (IODP). Here we present the first microbiological characterization of the formation fluids from cold, oxygenated igneous crust at North Pond on the western flank of the Mid Atlantic Ridge. Fluids were collected from two CORKs installed at IODP boreholes 1382A and 1383C and include fluids from three different depth horizons within oceanic crust. Collection of borehole fluids was monitored in situ using an oxygen optode and solid-state voltammetric electrodes. In addition, discrete samples were analyzed on deck using a comparable lab-based system as well as a membrane-inlet mass spectrometer to quantify all dissolved volatiles up to 200 daltons. The instruments were operated in parallel and both in situ and shipboard geochemical measurements point to a highly oxidized fluid, revealing an apparent slight depletion of oxygen in subsurface fluids (~215μM) relative to bottom seawater (~245μM). We were unable to detect reduced hydrocarbons, e.g. methane. Cell counts indicated the presence of roughly 2 x 10^4 cells per ml in all fluid samples, and DNA was extracted and amplified for the identification of both bacterial and archaeal community members. The utilization of ammonia, nitrate, dissolved inorganic carbon, and acetate was measured using stable isotopes, and oxygen consumption was monitored to provide an estimate of the rate of respiration per cell per day. These results provide the first dataset describing the diversity of microbes present in cold, oxygenated ocean crustal fluids and the biogeochemical processes they mediate in the subseafloor.
NASA Astrophysics Data System (ADS)
Lisabeth, Harrison Paul
Interaction of rocks with fluids can significantly change mineral assemblage and structure. This so-called hydrothermal alteration is ubiquitous in the Earth's crust. Though the behavior of hydrothermally altered rocks can have planet-scale consequences, such as facilitating oceanic spreading along slow ridge segments and recycling volatiles into the mantle at subduction zones, the mechanisms involved in the hydrothermal alteration are often microscopic. Fluid-rock interactions take place where the fluid and rock meet. Fluid distribution, flux rate and reactive surface area control the efficiency and extent of hydrothermal alteration. Fluid-rock interactions, such as dissolution, precipitation and fluid mediated fracture and frictional sliding lead to changes in porosity and pore structure that feed back into the hydraulic and mechanical behavior of the bulk rock. Examining the nature of this highly coupled system involves coordinating observations of the mineralogy and structure of naturally altered rocks and laboratory investigation of the fine scale mechanisms of transformation under controlled conditions. In this study, I focus on fluid-rock interactions involving two common lithologies, carbonates and ultramafics, in order to elucidate the coupling between mechanical, hydraulic and chemical processes in these rocks. I perform constant strain-rate triaxial deformation and constant-stress creep tests on several suites of samples while monitoring the evolution of sample strain, permeability and physical properties. Subsequent microstructures are analyzed using optical and scanning electron microscopy. This work yields laboratory-based constraints on the extent and mechanisms of water weakening in carbonates and carbonation reactions in ultramafic rocks. I find that inundation with pore fluid thereby reducing permeability. This effect is sensitive to pore fluid saturation with respect to calcium carbonate. Fluid inundation weakens dunites as well. The addition of carbon dioxide to pore fluid enhances compaction and partial recovery of strength compared to pure water samples. Enhanced compaction in CO2-rich fluid samples is not accompanied by enhanced permeability reduction. Analysis of sample microstructures indicates that precipitation of carbonates along fracture surfaces is responsible for the partial restrengthening and channelized dissolution of olivine is responsible for permeability maintenance.
Kratz, Thomas; Simon, Christina; Fendrich, Volker; Schneider, Ralph; Wulf, Hinnerk; Kratz, Caroline; Efe, Turgay; Schüttler, Karl F; Zoremba, Martin
2016-11-14
Goal directed fluid management in major abdominal surgery has shown to reduce perioperative complications. The approach aims to optimize the intravascular fluid volume by use of minimally invasive devices which calculate flow-directed variables such as stroke volume (SV) and stroke volume variation (SVV). We aimed to show the feasibility of routinely implementing this type of hemodynamic monitoring during pancreatic surgery, and to evaluate its effects in terms of perioperative fluid management and postoperative outcomes. All patients undergoing pancreatic surgery at a university hospital during two successive 12 months periods were included in this retrospective cohort analysis. Twelve months after the implementation of a standard operating procedure for a goal directed therapy (GDT, N = 45) using a pulse contour automated hemodynamic device were compared with a similar period before its use (control, N = 31) regarding mortality, length of hospital and ICU stay, postoperative complications and the use of fluids and vasopressors. Overall, 76 patients were analysed. Significantly less crystalloids were used in the GDT group. Patients receiving GDT showed significantly fewer severe complications (insufficiency of intestinal anastomosis: 0 vs. 5 (P = 0.0053) and renal failure: 0 vs. 4 (P = 0.0133). Mortality for pancreatic surgery was 1 vs. 3 patients, (P = 0.142), and length of stay (LOS) in the intensive care unit (ICU) was 4.38 ± 3.63 vs. 6.87 ± 10.02 (P= 0.0964) days. Use of blood products was significantly less within the GDT group. Implementation of a SOP for a GDT in the daily routine using flow-related parameters is feasible and is associated with better outcomes in pancreatic surgery.
Code of Federal Regulations, 2014 CFR
2014-07-01
... test evaluates base fluid biodegradation rates by monitoring gas production due to microbial... ppm) evaluates the anaerobic (redox) condition of the bottles (dye is blue when oxygen is present... this publication is for descriptive use only, and does not constitute endorsement by EPA or the authors...
Code of Federal Regulations, 2012 CFR
2012-07-01
... test evaluates base fluid biodegradation rates by monitoring gas production due to microbial... ppm) evaluates the anaerobic (redox) condition of the bottles (dye is blue when oxygen is present... this publication is for descriptive use only, and does not constitute endorsement by EPA or the authors...
Code of Federal Regulations, 2013 CFR
2013-07-01
... test evaluates base fluid biodegradation rates by monitoring gas production due to microbial... ppm) evaluates the anaerobic (redox) condition of the bottles (dye is blue when oxygen is present... this publication is for descriptive use only, and does not constitute endorsement by EPA or the authors...
Code of Federal Regulations, 2012 CFR
2012-07-01
... for air leaks, torn or broken bags or filter media, or any other condition that may cause an increase... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF... nozzles must conduct a daily check of the air or water pressure to the spray nozzles and record the...
NASA Astrophysics Data System (ADS)
Schaen, A. T.; Ding, K.; Seyfried, W. E.
2013-12-01
Developments in electrochemistry and material science have facilitated the construction of ceramic (YSZ) based chemical sensor systems that can be used to measure and monitor pH and redox in aqueous fluids at elevated temperatures and pressures. In recent years, these sensor systems have been deployed to acquire real-time and time series in-situ data for high-temperature hydrothermal vent fluids at the Main Endeavour Field (Juan de Fuca Ridge), 9oN (East Pacific Rise), and at the ultramafic-hosted Rainbow field (36oN, Mid-Atlantic Ridge). Here we review in-situ pH data measured at these sites and apply these data to estimate the pH of fluids ascending to the seafloor from hydrothermal alteration zones deeper in the crust. In general, in-situ pH measured at virtually all vent sites is well in excess of that measured shipboard owing to the effects of temperature on the distribution of aqueous species and the solubility of metal sulfides, especially Cu and Zn, originally dissolved in the vent fluids. In situ pH measurements determined at MEF (Sully vent) and EPR 9oN (P-vent) in 2005 and 2008 were 4.4 ×0.02 and 5.05×0.05, respectively. The temperature and pressure (seafloor) of the vent fluids at each of the respective sites were 356oC and 220 bar, and 380oC and 250 bar. Plotting these data with respect to fluid density reveals that the in-situ pH of each vent fluid is approximately 1.5 pH units below neutrality. The density-pH (in-situ) correlation, however, is important because it provides a means from which the vent fluids were derived. Using dissolved silica and chloride from fluid samples at the MEF (Sully) suggest T/P conditions of approximately 435oC, 380 bar, based on quartz-fluid and NaCl-H2O systems. At the fluid density calculated for these conditions, pH (in-situ) is predicted to be ~6.2. Attempts are presently underway to assess the effect of the calculated pH on metal sulfide and silicate (e.g., plagioclase, chlorite) solubility in comparison with constraints imposed by the full range of chemical components in the vent fluids sampled and analyzed in association with pH (in-situ) measurements. Since pH is a master variable in all geochemical systems, the novel approach proposed here may provide new insight on hydrothermal alteration processes at conditions difficult or impossible to assess by more traditional means, ultimately influencing hydrothermal fluid fluxes.
Moser, Othmar; Yardley, Jane E.; Bracken, Richard M.
2018-01-01
Continuous and flash glucose monitoring systems measure interstitial fluid glucose concentrations within a body compartment that is dramatically altered by posture and is responsive to the physiological and metabolic changes that enable exercise performance in individuals with type 1 diabetes. Body fluid redistribution within the interstitial compartment, alterations in interstitial fluid volume, changes in rate and direction of fluid flow between the vasculature, interstitium and lymphatics, as well as alterations in the rate of glucose production and uptake by exercising tissues, make for caution when interpreting device read-outs in a rapidly changing internal environment during acute exercise. We present an understanding of the physiological and metabolic changes taking place with acute exercise and detail the blood and interstitial glucose responses with different forms of exercise, namely sustained endurance, high-intensity, and strength exercises in individuals with type 1 diabetes. Further, we detail novel technical information on currently available patient devices. As more health services and insurance companies advocate their use, understanding continuous and flash glucose monitoring for its strengths and limitations may offer more confidence for patients aiming to manage glycemia around exercise. PMID:29342932
Conference on Fluid Machinery, 8th, Budapest, Hungary, Sept. 1987, Proceedings. Volumes 1 & 2
NASA Astrophysics Data System (ADS)
Szabo, A.; Kisbocskoi, L.
The present conference on turbomachine fluid mechanics gives attention to the analysis of labyrinth seals, irrigation turbomachinery, axial-flow fans, poppet valves, the generation of Karman vortices, self-rectifying Wells-type air turbines, computer simulations for water-supply systems, the computation of meridional flow in turbomachines, entrained air effects on vortex pump performance, the three-dimensional potential flow in a draft tube, and hydro powerplant diagnostic methods. Also discussed are a mathematical model for the initiation of cavitation wear, cryogenic flow in ejectors, flow downstream of guide vanes in a Kaplan turbine, unsteady flow in rotating cascades, novel methods for turbomachine vibration monitoring, cavitation breakdown in centrifugal pumps, test results for Banki turbines, centrifugal compressor return-channel flow, performance predictions for regenerative turbomachines, and secondary flows in a centrifugal pump.
Shin, Euisup; Kim, Ill Yong; Cho, Sung Baek; Ohtsuki, Chikara
2015-03-01
Hydroxyapatite formation on the surfaces of implanted materials plays an important role in osteoconduction of bone substitutes in bone tissues. Titania hydrogels are known to instigate hydroxyapatite formation in a solution mimicking human blood plasma. To date, the relationship between the surface characteristics of titania and hydroxyapatite formation on its surface remains unclear. In this study, titania powders with varying surface characteristics were prepared by addition of manganese or iron to examine hydroxyapatite formation in a type of simulated body fluid (Kokubo solution). Hydroxyapatite formation was monitored by observation of deposited particles with scale-like morphology on the prepared titania powders. The effect of the titania surface characteristics, i.e., crystal structure, zeta potential, hydroxy group content, and specific surface area, on hydroxyapatite formation was examined. Hydroxyapatite formation was observed on the surface of titania powders that were primarily anatase, and featured a negative zeta potential and low specific surface areas irrespective of the hydroxy group content. High specific surface areas inhibited the formation of hydroxyapatite because calcium and phosphate ions were mostly consumed by adsorption on the titania surface. Thus, these surface characteristics of titania determine its osteoconductivity following exposure to body fluid. Copyright © 2014 Elsevier B.V. All rights reserved.
Frasca, Denis; Dahyot-Fizelier, Claire; Adier, Christophe; Mimoz, Olivier; Debaene, Bertrand; Couet, William; Marchand, Sandrine
2014-01-01
The distribution of metronidazole in the central nervous system has only been described based on cerebrospinal fluid data. However, extracellular fluid (ECF) concentrations may better predict its antimicrobial effect and/or side effects. We sought to explore by microdialysis brain ECF metronidazole distribution in patients with acute brain injury. Four brain-injured patients monitored by cerebral microdialysis received 500 mg of metronidazole over 0.5 h every 8 h. Brain dialysates and blood samples were collected at steady state over 8 h. Probe recoveries were evaluated by in vivo retrodialysis in each patient for metronidazole. Metronidazole and OH-metronidazole were assayed by high-pressure liquid chromatography, and a noncompartmental pharmacokinetic analysis was performed. Probe recovery was equal to 78.8% ± 1.3% for metronidazole in patients. Unbound brain metronidazole concentration-time curves were delayed compared to unbound plasma concentration-time curves but with a mean metronidazole unbound brain/plasma AUC0-τ ratio equal to 102% ± 19% (ranging from 87 to 124%). The unbound plasma concentration-time profiles for OH-metronidazole were flat, with mean average steady-state concentrations equal to 4.0 ± 0.7 μg ml(-1). This microdialysis study describes the steady-state brain distribution of metronidazole in patients and confirms its extensive distribution.
Continuous glucose monitoring for patients with diabetes: an evidence-based analysis.
2011-01-01
To determine the effectiveness and cost-effectiveness of continuous glucose monitoring combined with self-monitoring of blood glucose compared with self-monitoring of blood glucose alone in the management of diabetes. CONDITION AND TARGET POPULATION Diabetes is a chronic metabolic disorder that interferes with the body's ability to produce or effectively use insulin. In 2005, an estimated 816,000 Ontarians had diabetes representing 8.8% of the province's population. Type 1 or juvenile onset diabetes is a life-long disorder that commonly manifests in children and adolescents. It represents about 10% of the total diabetes population and involves immune-mediated destruction of insulin producing cells in the pancreas. The loss of these cells necessitates insulin therapy. Type 2 or "adult-onset" diabetes represents about 90% of the total diabetes population and is marked by a resistance to insulin or insufficient insulin secretion. The risk of developing type 2 diabetes increases with age, obesity and lack of physical activity. Approximately 30% of patients with type 2 diabetes eventually require insulin therapy. Continuous glucose monitors (CGM) measure glucose levels in the interstitial fluid surrounding skin cells. These measurements supplement conventional self monitoring of blood glucose (SMBG) by monitoring the glucose fluctuations continuously over a stipulated period of time, thereby identifying fluctuations that would not be identified with SMBG alone. To use a CGM, a sensor is inserted under the skin to measure glucose in the interstitial fluid. The sensor is wired to a transmitter. The device requires calibration using a capillary blood glucose measurement. Each sensor continuously measures glucose every 5-10 seconds averaging these values every 5 minutes and storing this data in the monitors memory. Depending on the device used, the algorithm in the device can measure glucose over a 3 or 6 day period using one sensor. After the 3 or 6 day period, a new sensor is required. The device is equipped with alarms which warn the patient of impending hypo-or hyperglycemia. Two types of CGM are available: Systems that is stored in a monitor and can be downloaded later.Real time systems that continuously provide the actual glucose concentration on a display. What is the effectiveness and cost-effectiveness of CGM combined with SMBG compared with SMBG alone in the management of diabetes? A literature search was performed on September 15, 2010 using OVID MEDLINE, MEDLINE In-Process and Other Non-Indexed Citations, EMBASE, the Cumulative Index to Nursing & Allied Health Literature (CINAHL), the Cochrane Library, and the International Agency for Health Technology Assessment (INAHTA) for studies published from January 1, 2002 until September 15, 2010. Abstracts were reviewed by a single reviewer and, for those studies meeting the eligibility criteria, full-text articles were obtained. Reference lists were also examined for any additional relevant studies not identified through the search. Articles with unknown eligibility were reviewed with a second clinical epidemiologist, then a group of epidemiologists until consensus was established. The quality of evidence was assessed as high, moderate, low or very low according to GRADE methodology. English languageRandomized controlled trials (N>30 patients)Adults or pediatric patients with insulin dependent diabetes (type 1 or 2 or gestational)Studies comparing CGM plus SMBG versus SMBG alone Case studiesStudies that did not compare CGM plus SMBG versus SMBG aloneStudies that did not report statistical analysis of outcomes or data was unextractable Change in glycosylated hemoglobin (HbA1c)Frequency or duration of hypo-or hyperglycemic episodes or euglycemiaAdverse effects Moderate quality evidence that CGM + SMBG: is not more effective than self monitoring of blood glucose (SMBG) alone in the reduction of HbA1c using insulin infusion pumps for Type 1 diabetes.is not more effective than SMBG alone in the reduction of hypoglycemic or severe hypoglycemic events using insulin infusion pumps for Type 1 diabetes.
White, Charles R; Haidekker, Mark A; Stevens, Hazel Y; Frangos, John A
2004-01-01
Hand–arm vibration syndrome is a vascular disease of occupational origin and a form of secondary Raynaud's phenomenon. Chronic exposure to hand-held vibrating tools may cause endothelial injury. This study investigates the biomechanical forces involved in the transduction of fluid vibration in the endothelium. Human endothelial cells were exposed to direct vibration and rapid low-volume fluid oscillation. Rapid low-volume fluid oscillation was used to simulate the effects of vibration by generating defined temporal gradients in fluid shear stress across an endothelial monolayer. Extracellular signal-regulated kinase (ERK1/2) phosphorylation and endothelin-1 (ET-1) release were monitored as specific biochemical markers for temporal gradients and endothelial response, respectively. Both vibrational methods were found to phosphorylate ERK1/2 in a similar pattern. At a fixed frequency of fluid oscillation where the duration of each pulse cycle remained constant, ERK1/2 phosphorylation increased with the increasing magnitude of the applied temporal gradient. However, when the frequency of flow oscillation was increased (thus decreasing the duration of each pulse cycle), ERK1/2 phosphorylation was attenuated across all temporal gradient flow profiles. Fluid oscillation significantly stimulated ET-1 release compared to steady flow, and endothelin-1 was also attenuated with the increase in oscillation frequency. Taken together, these results show that both the absolute magnitude of the temporal gradient and the frequency/duration of each pulse cycle play a role in the biomechanical transduction of fluid vibrational forces in endothelial cells. Furthermore, this study reports for the first time a link between the ERK1/2 signal transduction pathway and transmission of vibrational forces in the endothelium. PMID:14724194
DOE Office of Scientific and Technical Information (OSTI.GOV)
Findlay, Rick
The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office (NNSA/NSO) initiated the Offsites Project to characterize the risk posed to human health and the environment as a result of testing at formerly used nuclear sites in Alaska, Colorado, Mississippi, Nevada, and New Mexico. The scope of this Fluid Management Plan (FMP) is to support the subsurface investigation at the Project Shoal Area (PSA) Corrective Action Unit (CAU) 447, Shoal - Subsurface, Nevada, in accordance with the ''Federal Facility Agreement and Consent Order'' (FFACO) (1996). Corrective Action Unit 447 is located in the Sand Spring Range, southmore » of Highway 50, about 39 miles southeast of Fallon, Nevada. (Figure 1-1). This FMP will be used at the PSA in lieu of an individual discharge permit for each well or a general water pollution control permit for management of all fluids produced during the drilling, construction, development, testing, experimentation, and/or sampling of wells conducted by the Offsites Project. The FMP provides guidance for the management of fluids generated during investigation activities and provides the standards by which fluids may be discharged on site. Although the Nevada Division of Environmental Protection (NDEP), Bureau of Federal Facilities (BoFF) is not a signatory to this FMP, it is involved in the negotiation of the contents of this plan and approves the conditions contained within. The major elements of this FMP include: (1) establishment of a well-site operations strategy; (2) site design/layout; (3) monitoring of contamination indicators (monitoring program); (4) sump characterization (sump sampling program); (5) fluid management decision criteria and fluid disposition; and (6) reporting requirements.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tim Echelard
The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office (NNSA/NSO) initiated the Offsites Project to characterize the risk posed to human health and the environment as a result of testing at formerly used nuclear sites in Alaska, Colorado, Mississippi, Nevada, and New Mexico. The scope of this Fluid Management Plan (FMP) is to support the subsurface investigation at the Project Shoal Area (PSA) Corrective Action Unit (CAU) 447, Shoal-Subsurface, Nevada, in accordance with the ''Federal Facility Agreement and Consent Order'' (FFACO) (1996). Corrective Action Unit 447 is located in the Sand Spring Range, south of Highwaymore » 50, about 39 miles southeast of Fallon, Nevada. (Figure 1-1). This FMP will be used at the PSA in lieu of an individual discharge permit for each well or a general water pollution control permit for management of all fluids produced during the drilling, construction, development, testing, experimentation, and/or sampling of wells conducted by the Offsites Project. The FMP provides guidance for the management of fluids generated during investigation activities and provides the standards by which fluids may be discharged on site. Although the Nevada Division of Environmental Protection (NDEP), Bureau of Federal Facilities (BoFF) is not a signatory to this FMP, it is involved in the negotiation of the contents of this plan and approves the conditions contained within. The major elements of this FMP include: (1) establishment of a well-site operations strategy; (2) site design/layout; (3) monitoring of contamination indicators (monitoring program); (4) sump characterization (sump sampling program); (5) fluid management decision criteria and fluid disposition; and (6) reporting requirements.« less
NASA Astrophysics Data System (ADS)
Krzmarzick, M. J.; McCutchan, A.; Carroll, J.; Lozano, T.
2017-12-01
Hydraulic fracturing of oil and gas formations has revolutionized the industry, but little is known regarding the interactions of the microbiology in formations and the hydraulic fracturing chemicals used. In the first part of this study, six representative hydraulic fracturing fluids were incubated in bench scale microcosms with surface soils over six months at 1× concentrations used in the field. These fluids differed greatly in terms of biocide, surfactants, corrosion inhibitors and crosslinking agents (if any). The changes in microbial communities were measured by Illumina 16S rRNA gene analysis and quantitative-PCR. As a whole, the microbial communities enriched were significantly varied between fluids, with the magnitude of the difference tightly linked to the total organic carbon of each fluid. Most enriched bacteria heavily grew within just the first couple of weeks, and belonged to genera well-linked to xenobiotic degradation, such as Azospirillum, Ralstonia, and Comamonas. This, combined with bulk parameters such as chemical oxygen demand of the water, indicates that a significant fraction of these fluids are readily degradable, though individual chemicals were not monitored for recalcitrance. In the second component of this work, the flowback waters from sixteen newly completed wells in south-central Oklahoma were monitored over two months for compositions of boron, dissolved solids, BTEX, chloride, and their microbial communities. As expected, dissolved solids increased over time as the flowback waters became more characteristic of the formation waters. In these wells, boron, a carefully measured component of the fracturing fluid for cross-linking applications, was either stable or increased over time. The microbial community characteristics are pending but will be compared between formations, to the chemical data, and to the results in the bench-top degradation study.
Review of Prospects of Biological Fluid Biomarkers in Osteoarthritis
Nguyen, Lich Thi; Sharma, Ashish Ranjan; Chakraborty, Chiranjib; Saibaba, Balaji; Ahn, Moo-Eob; Lee, Sang-Soo
2017-01-01
Osteoarthritis (OA) is a degenerative disease of the joints and is one of the leading causes of disability in adults. However, there are no key therapeutics for OA and medical treatment is based on managing the symptoms and slowing down progression of the disease. Diagnostics based on clinical examination and radiography have provided little information about metabolic changes in joint tissues, disease onset and progression. Due to lack of effective methods for early detection and evaluation of treatment outcome, the measurement of biochemical markers (biomarkers) shows promise as a prospective method aiding in disease monitoring. OA biomarkers that are present in biological fluids such as blood, urine and synovial fluid, sources that are easily isolated from body, are of particular interest. Moreover, there are increasingly more studies identifying and developing new biomarkers for OA. In this review, efforts have been made to summarize the biomarkers that have been reported in recent studies on patients. We also tried to classify biomarkers according to tissue metabolism (bone, cartilage and synovial metabolism markers), pathological pathways (inflammatory and genetic markers) and biological function (chemokines, growth factors, acute phase proteins, etc.). PMID:28287489
Kroll, Kayla A.; Cochran, Elizabeth S.; Murray, Kyle E.
2017-01-01
The Arbuckle Group (Arbuckle) is a basal sedimentary unit that is the primary target for saltwater disposal in Oklahoma. Thus, the reservoir characteristics of the Arbuckle, including how the poroelastic properties change laterally and over time are of significant interest. We report observations of fluid level changes in two monitoring wells in response to the 3 September 2016 Mw 5.8 Pawnee and the 7 November 2016 Mw 5.0 Cushing earthquakes. We investigate the relationship between static strain resulting from these events and the fluid level changes observed in the wells. We model the fluid level response by estimating static strains from a set of earthquake source parameters and spatiotemporal poroelastic properties of the Arbuckle in the neighborhood of the monitoring wells. Results suggest that both the direction of the observed fluid level step and the amplitude can be predicted from the computed volumetric strain change and a reasonable set of poroelastic parameters. Modeling results indicate that poroelastic parameters differ at the time of the Pawnee and Cushing earthquakes, with a moderately higher Skempton’s coefficient required to fit the response to the Cushing earthquake. This may indicate that dynamic shaking resulted in physical alteration of the Arbuckle at distances up to ∼50 km from the Pawnee earthquake.
Haque, Anwarul; Mirza, Sadiq; Jafri, Sidra Kaleem; Naseem, Faizia; Khan, Khalid Mahmood; Afzal, Muhammad Faheem; Hamid, Muhammad Haroon
2016-01-01
Isotonic saline is recommended as maintenance intravenous fluid therapy (MIVFT) for most of the acutely ill hospitalized children. The aim of this study is to assess the current knowledge of paediatric residents regarding the selection of MIVFT in hospitalized children. We conducted a paper-based questionnaire survey to paediatric residents from ten centres asking selection of MIVFT in four common clinical scenarios in 6-month and 10-year old patients as well as monitoring of fluid balance and electrolyte. 445 responses were collected (>90% response rate). Majority [78.3% (n=348)] of them were FCPS-trainees. The 0.9%, 0.45% and 0.2% solution were selected by 45.8%, 43.98% and 10.92% respectively. The isotonic and hypotonic solution was prescribed in 6- mo (35.22% vs. 64.76% [p<0.001]) and 10-year (54.49% vs. 44.98%) in four different clinical scenarios respectively. 0.45% solution was most commonly prescribed MIVFT in pneumonia (50.22%) and meningitis (45.39%) and 0.9% solution was most commonly selected in acute gastroenteritis (55.05%) and post-operative patients (51.23%). Fluid balance and electrolyte monitoring were selected by 96.9% and 55.7% respondents respectively. Our survey reports that more than fifty percent of paediatric residents have inadequate knowledge about maintenance intravenous fluid therapy in acutely ill hospitalized children.
NASA Astrophysics Data System (ADS)
Thiel, Stephan
2017-09-01
Hydraulic fracking is a geoengineering application designed to enhance subsurface permeability to maximize fluid and gas flow. Fracking is commonly used in enhanced geothermal systems (EGS), tight shale gas, and coal seam gas (CSG) plays and in CO_2 storage scenarios. Common monitoring methods include microseismics and mapping small earthquakes with great resolution associated with fracture opening at reservoir depth. Recently, electromagnetic (EM) methods have been employed in the field to provide an alternative way of direct detection of fluids as they are pumped in the ground. Surface magnetotelluric (MT) measurements across EGS show subtle yet detectable changes during fracking derived from time-lapse MT deployments. Changes are directional and are predominantly aligned with current stress field, dictating preferential fracture orientation, supported by microseismic monitoring of frack-related earthquakes. Modeling studies prior to the injection are crucial for survey design and feasibility of monitoring fracks. In particular, knowledge of sediment thickness plays a fundamental role in resolving subtle changes. Numerical forward modeling studies clearly favor some form of downhole measurement to enhance sensitivity; however, these have yet to be conclusively demonstrated in the field. Nevertheless, real surface-based monitoring examples do not necessarily replicate the expected magnitude of change derived from forward modeling and are larger than expected in some cases from EGS and CSG systems. It appears the injected fluid volume alone cannot account for the surface change in resistivity, but connectedness of pore space is also significantly enhanced and nonlinear. Recent numerical studies emphasize the importance of percolation threshold of the fracture network on both electrical resistivity and permeability, which may play an important role in accounting for temporal changes in surface EM measurements during hydraulic fracking.
NASA Astrophysics Data System (ADS)
Pezeshkpour, Parsa
The requirements of environmental assessments and of understanding and monitoring in-situ mass and heat processes in porous media have led to the development of geophysical methods for remote mapping and monitoring of contaminant plumes and fluid migration. With the possible exception of seismic approaches, electrical methods known as Electrical Resistivity Tomography (ERT) have become the most widely studied and used for these purposes. Wherever a sufficient contrast in ground resistivity is generated by human or natural processes, monitoring the resistivity structure over time may give insight into these processes. ERT has monitoring applications in processes such as Enhanced Oil Recovery (EOR), Slurry Fracture Injection (SFI), and monitoring transport processes in hydrogeology. A permanent electrode arrangement for long term monitoring removes the effects of Earth's heterogeneity and anisotropy when a process is analyzed as a function of time. As a starting point on the work described in this thesis, ERT data were collected from a Cambridge, Ontario, sand pit before, immediately after and one week following a 11000 liters slurry injection. These measurements verified that ERT could detect changes caused by the injection and later movement of this conductive mixture in the ground. The commercial equipment used for these measurements was not well suited to the tasks, mainly because it was extremely slow. Further, there was a lack of robust and user-friendly three-dimensional modeling software to use as a means of predicting response and---eventually---as the engine of an inversion routine. Finally, it was difficult to analyze the injection situation in terms of how best to place a limited number of surface and borehole electrodes to most effectively monitor the injection fluids. The remainder of the thesis addresses these problems. The first objective was to design and construct a more suitable ERT measurement system. The second objective was to adapt SALTFLOW as a platform for both the resistivity and hydrogeological modeling of the saline groundwater flow resulting from waste injection. The third objective was to develop methods of sensitivity analysis that will allow a more efficient examination of the electrode arrays that could be effectively used in a given situation. The fourth objective was to demonstrate the ERT method and the improvements undertaken by the author on the data collected at the Cambridge injection site. The thesis has not, in fact, met all these objectives, but has made substantial progress towards them. The complete design of the measurement system and the construction of its potential measurement components were achieved. A lack of capacity in the science shops, however, resulted in the power (current) supply not being constructed in time for field evaluation of the injection or its aftermath. (Abstract shortened by UMI.)
The pre-synaptic vesicle protein synaptotagmin is a novel biomarker for Alzheimer's disease.
Öhrfelt, Annika; Brinkmalm, Ann; Dumurgier, Julien; Brinkmalm, Gunnar; Hansson, Oskar; Zetterberg, Henrik; Bouaziz-Amar, Elodie; Hugon, Jacques; Paquet, Claire; Blennow, Kaj
2016-10-03
Synaptic degeneration is a central pathogenic event in Alzheimer's disease that occurs early during the course of disease and correlates with cognitive symptoms. The pre-synaptic vesicle protein synaptotagmin-1 appears to be essential for the maintenance of an intact synaptic transmission and cognitive function. Synaptotagmin-1 in cerebrospinal fluid is a candidate Alzheimer biomarker for synaptic dysfunction that also may correlate with cognitive decline. In this study, a novel mass spectrometry-based assay for measurement of cerebrospinal fluid synaptotagmin-1 was developed, and was evaluated in two independent sample sets of patients and controls. Sample set I included cerebrospinal fluid samples from patients with dementia due to Alzheimer's disease (N = 17, age 52-86 years), patients with mild cognitive impairment due to Alzheimer's disease (N = 5, age 62-88 years), and controls (N = 17, age 41-82 years). Sample set II included cerebrospinal fluid samples from patients with dementia due to Alzheimer's disease (N = 24, age 52-84 years), patients with mild cognitive impairment due to Alzheimer's disease (N = 18, age 58-83 years), and controls (N = 36, age 43-80 years). The reproducibility of the novel method showed coefficients of variation of the measured synaptotagmin-1 peptide 215-223 (VPYSELGGK) and peptide 238-245 (HDIIGEFK) of 14 % or below. In both investigated sample sets, the CSF levels of synaptotagmin-1 were significantly increased in patients with dementia due to Alzheimer's disease (P ≤ 0.0001) and in patients with mild cognitive impairment due to Alzheimer's disease (P < 0.001). In addition, in sample set I the synaptotagmin-1 level was significantly higher in patients with mild cognitive impairment due to Alzheimer's disease compared with patients with dementia due to Alzheimer's disease (P ≤ 0.05). Cerebrospinal fluid synaptotagmin-1 is a promising biomarker to monitor synaptic dysfunction and degeneration in Alzheimer's disease that may be useful for clinical diagnosis, to monitor effect on synaptic integrity by novel drug candidates, and to explore pathophysiology directly in patients with Alzheimer's disease.
NASA Astrophysics Data System (ADS)
Salzer, Jacqueline T.; Milillo, Pietro; Varley, Nick; Perissin, Daniele; Pantaleo, Michele; Walter, Thomas R.
2017-04-01
Active volcanoes often display cyclic behaviour with alternating quiescent and eruptive periods. Continuously monitoring volcanic processes such as deformation, seismicity and degassing, irrespective of their current status, is crucial for understanding the parameters governing the fluid transport within the edifice and the transitions between different regimes. However, mapping the deformation and details of fluid escape at the summit of steep sloped volcanoes and integrating these with other types of data is challenging. Here we present for the first time the near-3D surface deformation field derived from high resolution radar interferometry (InSAR) acquired by the satellite TerraSAR-X at a degassing volcano dome and interpret the results in combination with overflight infrared and topographic data. We find that the results strongly differ depending on the chosen InSAR time series method, which potentially overprints the true physical complexities of small scale, shallow deformation processes. We present a new method for accurate mapping of heterogeneities in the dome deformation, and comparison to the topography and precisely located surface temperature anomalies. The identified deformation is dominated by strong but highly localized subsidence of the summit dome. Our results highlight the competing effects of the topography, permeability and shallow volcanic structures controlling the degassing pathways. On small spatial scales compaction sufficiently reduced the dome permeability to redirect the fluid flow. High resolution InSAR monitoring of volcanic domes thus provides valuable data for constraining models of their internal structure, degassing pathways and densification processes.
Lin, Hancheng; Luo, Yiwen; Sun, Qiran; Zhang, Ji; Tuo, Ya; Zhang, Zhong; Wang, Lei; Deng, Kaifei; Chen, Yijiu; Huang, Ping; Wang, Zhenyuan
2018-02-20
Many studies have proven the usefulness of biofluid-based infrared spectroscopy in the clinical domain for diagnosis and monitoring the progression of diseases. Here we present a state-of-the-art study in the forensic field that employed Fourier transform infrared microspectroscopy for postmortem diagnosis of sudden cardiac death (SCD) by in situ biochemical investigation of alveolar edema fluid in lung tissue sections. The results of amide-related spectral absorbance analysis demonstrated that the pulmonary edema fluid of the SCD group was richer in protein components than that of the neurologic catastrophe (NC) and lethal multiple injuries (LMI) groups. The complementary results of unsupervised principle component analysis (PCA) and genetic algorithm-guided partial least-squares discriminant analysis (GA-PLS-DA) further indicated different global spectral band patterns of pulmonary edema fluids between these three groups. Ultimately, a random forest (RF) classification model for postmortem diagnosis of SCD was built and achieved good sensitivity and specificity scores of 97.3% and 95.5%, respectively. Classification predictions of unknown pulmonary edema fluid collected from 16 cases were also performed by the model, resulting in 100% correct discrimination. This pilot study demonstrates that FTIR microspectroscopy in combination with chemometrics has the potential to be an effective aid for postmortem diagnosis of SCD.
Parry, Gareth J; Rodrigues, Cecilia M P; Aranha, Marcia M; Hilbert, Sarah J; Davey, Cynthia; Kelkar, Praful; Low, Walter C; Steer, Clifford J
2010-01-01
Amyotrophic lateral sclerosis is a progressive degenerative disease, which typically leads to death in 3 to 5 years. Neuronal cell death offers a potential target for therapeutic intervention. Ursodeoxycholic acid is a cytoprotective, endogenous bile acid that has been shown to be neuroprotective in experimental Huntington and Alzheimer diseases, retinal degeneration, and ischemic and hemorrhagic stroke. The objective of this research was to study the safety and the tolerability of ursodeoxycholic acid in amyotrophic lateral sclerosis and document effective and dose-dependent cerebrospinal fluid penetration. Eighteen patients were randomly assigned to receive ursodeoxycholic acid at doses of 15, 30, and 50 mg/kg of body weight per day. Serum and cerebrospinal fluid were obtained for analysis after 4 weeks of treatment. Treatment-emergent clinical and laboratory events were monitored weekly. Our data indicated that ursodeoxycholic acid is well tolerated by all subjects at all doses. We also showed that ursodeoxycholic acid is well absorbed after oral administration and crosses the blood-brain barrier in a dose-dependent manner. These results show excellent safety and tolerability of ursodeoxycholic acid. The drug penetrates the cerebrospinal fluid in a dose-dependent manner. A large, placebo-controlled clinical trial is needed to assess the efficacy of ursodeoxycholic acid in treating amyotrophic lateral sclerosis.
Open Source Platform Application to Groundwater Characterization and Monitoring
NASA Astrophysics Data System (ADS)
Ntarlagiannis, D.; Day-Lewis, F. D.; Falzone, S.; Lane, J. W., Jr.; Slater, L. D.; Robinson, J.; Hammett, S.
2017-12-01
Groundwater characterization and monitoring commonly rely on the use of multiple point sensors and human labor. Due to the number of sensors, labor, and other resources needed, establishing and maintaining an adequate groundwater monitoring network can be both labor intensive and expensive. To improve and optimize the monitoring network design, open source software and hardware components could potentially provide the platform to control robust and efficient sensors thereby reducing costs and labor. This work presents early attempts to create a groundwater monitoring system incorporating open-source software and hardware that will control the remote operation of multiple sensors along with data management and file transfer functions. The system is built around a Raspberry PI 3, that controls multiple sensors in order to perform on-demand, continuous or `smart decision' measurements while providing flexibility to incorporate additional sensors to meet the demands of different projects. The current objective of our technology is to monitor exchange of ionic tracers between mobile and immobile porosity using a combination of fluid and bulk electrical-conductivity measurements. To meet this objective, our configuration uses four sensors (pH, specific conductance, pressure, temperature) that can monitor the fluid electrical properties of interest and guide the bulk electrical measurement. This system highlights the potential of using open source software and hardware components for earth sciences applications. The versatility of the system makes it ideal for use in a large number of applications, and the low cost allows for high resolution (spatially and temporally) monitoring.
Bergfeld, D.; Evans, William C.
2011-01-01
We report results of yearly measurements of the diffuse CO2 flux and shallow soil temperatures collected since 2006 across two sets of tree-kill areas at Long Valley Caldera, California. These data provide background information about CO2 discharge during a period with moderate seismicity, but little to no deformation. The tree kills are located at long-recognized areas of weak thermal fluid upflow, but have expanded in recent years, possibly in response to geothermal fluid production at Casa Diablo. The amount of CO2 discharged from the older kill area at Basalt Canyon is fairly constant and is around 3-5 tonnes of CO2 per day from an area of about 15,000 m2. The presence of isobutane in gas samples from sites in and around Basalt Canyon suggests that geothermal fluid production directly effects fluid upflow in the region close to the power plant. The average fluxes at Shady Rest are lower than average fluxes at Basalt Canyon, but the area affected by fluid upflow is larger. Total CO2 discharged from the central portion of the kill area at Shady Rest has been variable, ranging from 6 to11 tonnes per day across 61,000 m2. Gas collected at Shady Rest contains no detectable isobutane to link emissions chemically to geothermal fluid production, but two samples from 2009-10 have detectable H2S and suggest an increasing geothermal character of emitted gas. The appearance of this gas at the surface may signal increased drawdown of water levels near the geothermal productions wells.
Using well casing as an electrical source to monitor hydraulic fracture fluid injection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wilt, Michael; Nieuwenhuis, Greg; MacLennan, Kris
2016-03-09
The depth to surface resistivity (DSR) method transmits current from a source located in a cased or openhole well to a distant surface return electrode while electric field measurements are made at the surface over the target of interest. This paper presents both numerical modelling results and measured data from a hydraulic fracturing field test where conductive water was injected into a resistive shale reservoir during a hydraulic fracturing operation. Modelling experiments show that anomalies due to hydraulic fracturing are small but measureable with highly sensitive sensor technology. The field measurements confirm the model results,showing that measured differences in themore » surface fields due to hydraulic fracturing have been detected above the noise floor. Our results show that the DSR method is sensitive to the injection of frac fluids; they are detectable above the noise floor in a commercially active hydraulic fracturing operation, and therefore this method can be used for monitoring fracture fluid movement.« less
Sensor arrays for detecting analytes in fluids
NASA Technical Reports Server (NTRS)
Freund, Michael S. (Inventor); Lewis, Nathan S. (Inventor)
2000-01-01
A sensor array for detecting an analyte in a fluid, comprising at least first and second chemically sensitive resistors electrically connected to an electrical measuring apparatus, wherein each of the chemically sensitive resistors comprises a mixture of nonconductive material and a conductive material. Each resistor provides an electrical path through the mixture of nonconductive material and the conductive material. The resistors also provide a difference in resistance between the conductive elements when contacted with a fluid comprising an analyte at a first concentration, than when contacted with an analyte at a second different concentration. A broad range of analytes can be detected using the sensors of the present invention. Examples of such analytes include, but are not limited to, alkanes, alkenes, alkynes, dienes, alicyclic hydrocarbons, arenes, alcohols, ethers, ketones, aldehydes, carbonyls, carbanions, polynuclear aromatics, organic derivatives, biomolecules, sugars, isoprenes, isoprenoids and fatty acids. Moreover, applications for the sensors of the present invention include, but are not limited to, environmental toxicology, remediation, biomedicine, material quality control, food monitoring and agricultural monitoring.
BIOTEX--biosensing textiles for personalised healthcare management.
Coyle, Shirley; Lau, King-Tong; Moyna, Niall; O'Gorman, Donal; Diamond, Dermot; Di Francesco, Fabio; Costanzo, Daniele; Salvo, Pietro; Trivella, Maria Giovanna; De Rossi, Danilo Emilio; Taccini, Nicola; Paradiso, Rita; Porchet, Jacque-André; Ridolfi, Andrea; Luprano, Jean; Chuzel, Cyril; Lanier, Thierry; Revol-Cavalier, Frdéric; Schoumacker, Sébastien; Mourier, Véronique; Chartier, Isabelle; Convert, Reynald; De-Moncuit, Henri; Bini, Christina
2010-03-01
Textile-based sensors offer an unobtrusive method of continually monitoring physiological parameters during daily activities. Chemical analysis of body fluids, noninvasively, is a novel and exciting area of personalized wearable healthcare systems. BIOTEX was an EU-funded project that aimed to develop textile sensors to measure physiological parameters and the chemical composition of body fluids, with a particular interest in sweat. A wearable sensing system has been developed that integrates a textile-based fluid handling system for sample collection and transport with a number of sensors including sodium, conductivity, and pH sensors. Sensors for sweat rate, ECG, respiration, and blood oxygenation were also developed. For the first time, it has been possible to monitor a number of physiological parameters together with sweat composition in real time. This has been carried out via a network of wearable sensors distributed around the body of a subject user. This has huge implications for the field of sports and human performance and opens a whole new field of research in the clinical setting.
Huang, Lingli; Shi, Jingfei; Pan, Yuanhu; Wang, Liye; Chen, Dongmei; Xie, Shuyu; Liu, Zhenli; Yuan, Zonghui
2016-03-09
Ractopamine (RAC), a β-adrenergic leanness-enhancing agent, endangers the food safety of animal products because of overdosing and illegal use in food animals. Excretion and residue depletion of RAC in pigs and goats were investigated to determine a representative biological fluid or surface tissue for preslaughter monitoring. After a single oral gavage of RAC, 64-67% of the dose was excreted from the urine of pigs and goats within 12-24 h. RAC persisted the longest in the hair of pigs and goats but depleted rapidly in the plasma, muscle, and fat. Urine and hair were excellent for predicting RAC residues in edible tissues of pigs, whereas plasma and urine were satisfactory body fluids for the prediction of RAC concentrations in edible tissues of goats. These data provided a simple and economical preslaughter living monitoring method for the illegal use and violative residue of RAC in food animals.
NASA Technical Reports Server (NTRS)
Cantrell, John H. (Inventor); Yost, William T. (Inventor)
1994-01-01
Non-invasive measuring devices responsive to changes in a patient's intracranial pressure (ICP) can be accurately calibrated for monitoring purposes by providing known changes in ICP by non-invasive methods, such as placing the patient on a tilting bed and calculating a change in ICP from the tilt angle and the length of the patient's cerebrospinal column, or by placing a pressurized skull cap on the patient and measuring the inflation pressure. Absolute values for the patient's pressure-volume index (PVI) and the steady state ICP can then be determined by inducing two known changes in the volume of cerebrospinal fluid while recording the corresponding changes in ICP by means of the calibrated measuring device. The two pairs of data for pressure change and volume change are entered into an equation developed from an equation describing the relationship between ICP and cerebrospinal fluid volume. PVI and steady state ICP are then determined by solving the equation. Methods for inducing known changes in cerebrospinal fluid volume are described.
NASA Technical Reports Server (NTRS)
Yost, William T. (Inventor); Cantrell, Jr., John H. (Inventor)
1997-01-01
Non-invasive measuring devices responsive to changes in a patient's intracranial pressure (ICP) can be accurately calibrated for monitoring purposes by providing known changes in ICP by non-invasive methods, such as placing the patient on a tilting bed and calculating a change in ICP from the tilt angle and the length of the patient's cerebrospinal column, or by placing a pressurized skull cap on the patient and measuring the inflation pressure. Absolute values for the patient's pressure-volume index (PVI) and the steady state ICP can then be determined by inducing two known changes in the volume of cerebrospinal fluid while recording the corresponding changes in ICP by means of the calibrated measuring device. The two pairs of data for pressure change and volume change are entered into an equation developed from an equation describing the relationship between ICP and cerebrospinal fluid volume. PVI and steady state ICP are then determined by solving the equation. Methods for inducing known changes in cerebrospinal fluid volume are described.
40 CFR 60.105 - Monitoring of emissions and operations.
Code of Federal Regulations, 2010 CFR
2010-07-01
... liquid or solid fossil-fuels and the hours of operation during which liquid or solid fossil-fuels are... the atmosphere. The instrument shall be spanned at 60, 70, or 80 percent opacity. (2) For fluid... monitoring and recording the concentration by volume (dry basis) of CO emissions into the atmosphere, except...
40 CFR 60.105 - Monitoring of emissions and operations.
Code of Federal Regulations, 2012 CFR
2012-07-01
... liquid or solid fossil-fuels and the hours of operation during which liquid or solid fossil-fuels are... the atmosphere. The instrument shall be spanned at 60, 70, or 80 percent opacity. (2) For fluid... monitoring and recording the concentration by volume (dry basis) of CO emissions into the atmosphere, except...
40 CFR 60.105 - Monitoring of emissions and operations.
Code of Federal Regulations, 2013 CFR
2013-07-01
... liquid or solid fossil-fuels and the hours of operation during which liquid or solid fossil-fuels are... the atmosphere. The instrument shall be spanned at 60, 70, or 80 percent opacity. (2) For fluid... monitoring and recording the concentration by volume (dry basis) of CO emissions into the atmosphere, except...
40 CFR 60.105 - Monitoring of emissions and operations.
Code of Federal Regulations, 2014 CFR
2014-07-01
... liquid or solid fossil-fuels and the hours of operation during which liquid or solid fossil-fuels are... the atmosphere. The instrument shall be spanned at 60, 70, or 80 percent opacity. (2) For fluid... monitoring and recording the concentration by volume (dry basis) of CO emissions into the atmosphere, except...
40 CFR 60.105 - Monitoring of emissions and operations.
Code of Federal Regulations, 2011 CFR
2011-07-01
... liquid or solid fossil-fuels and the hours of operation during which liquid or solid fossil-fuels are... the atmosphere. The instrument shall be spanned at 60, 70, or 80 percent opacity. (2) For fluid... monitoring and recording the concentration by volume (dry basis) of CO emissions into the atmosphere, except...
Youssef, Jim A.; Orndorff, Douglas G.; Scott, Morgan A.; Ebner, Rachel E.; Knewitz, Allison P.
2014-01-01
Study Design Case report. Objective The objective of this study was to present the unusual case of a 59-year-old woman with a reoccurring sterile postoperative seroma. Methods A patient was observed postoperatively for any complications or adverse side effects resulting from an initial multilevel anterior/posterior lumbar fusion surgery where 2 g (1 g combined with the bone graft used for posterolateral fusion and 1 g placed in the soft tissues) of prophylactic vancomycin powder was placed within the soft tissues posteriorly before wound closure. The patient's progress was monitored through 6 months following the initial procedure. Six weeks postoperatively, the patient sustained a fall and had increased pain. Magnetic resonance imaging, computed tomography, and X-rays demonstrated a displaced sacral fracture, a large epidural fluid collection, and severe compression of the thecal sac at the lumbar operative sites (L3–5). Results On the basis of the aforementioned imaging studies and the patient's progressive neurologic deficit, it was apparent at the 6-week follow-up that emergent surgical intervention was necessary. Drainage and examination of an epidural fluid collection along with treatment of a displaced sacral fracture (S1–S2) were performed. The patient had an uneventful postoperative course with resolution of her back pain and neurologic deficit; however, recurrence of the epidural fluid collection requiring serial aspirations confounded the patients' clinical presentation. Conclusions With the recurrent nature of the seroma being unusual, the cause of the fluid collection and formation is undetermined. With lack of bone morphogenetic protein usage, and few confounding variables accountable, an acute allergic response to topical vancomycin powder is a possible etiology. Analysis with larger patient populations comparing postoperative adverse effects of prophylactic vancomycin powder is recommended. PMID:25364326
Youssef, Jim A; Orndorff, Douglas G; Scott, Morgan A; Ebner, Rachel E; Knewitz, Allison P
2014-10-01
Study Design Case report. Objective The objective of this study was to present the unusual case of a 59-year-old woman with a reoccurring sterile postoperative seroma. Methods A patient was observed postoperatively for any complications or adverse side effects resulting from an initial multilevel anterior/posterior lumbar fusion surgery where 2 g (1 g combined with the bone graft used for posterolateral fusion and 1 g placed in the soft tissues) of prophylactic vancomycin powder was placed within the soft tissues posteriorly before wound closure. The patient's progress was monitored through 6 months following the initial procedure. Six weeks postoperatively, the patient sustained a fall and had increased pain. Magnetic resonance imaging, computed tomography, and X-rays demonstrated a displaced sacral fracture, a large epidural fluid collection, and severe compression of the thecal sac at the lumbar operative sites (L3-5). Results On the basis of the aforementioned imaging studies and the patient's progressive neurologic deficit, it was apparent at the 6-week follow-up that emergent surgical intervention was necessary. Drainage and examination of an epidural fluid collection along with treatment of a displaced sacral fracture (S1-S2) were performed. The patient had an uneventful postoperative course with resolution of her back pain and neurologic deficit; however, recurrence of the epidural fluid collection requiring serial aspirations confounded the patients' clinical presentation. Conclusions With the recurrent nature of the seroma being unusual, the cause of the fluid collection and formation is undetermined. With lack of bone morphogenetic protein usage, and few confounding variables accountable, an acute allergic response to topical vancomycin powder is a possible etiology. Analysis with larger patient populations comparing postoperative adverse effects of prophylactic vancomycin powder is recommended.
Regional Analysis of the Effects of Oil and Gas Development on Groundwater Resources in California
NASA Astrophysics Data System (ADS)
Landon, M. K.; McMahon, P. B.; Kulongoski, J. T.; Ball, L. B.; Gillespie, J. M.; Shimabukuro, D.; Taylor, K. A.
2016-12-01
The California State Water Resources Control Board is collaborating with the U.S. Geological Survey to implement a Regional Monitoring Program (RMP) to assess potential interactions between oil/gas stimulation treatment and groundwater resources. The effects of stimulation on groundwater resources will be difficult to distinguish from the effects of other past or present components of oil and gas development. As a result, the RMP is designed to provide an overall assessment of the effects of oil and gas development on groundwater quality. During 2016-17, the study is focused on selected priority oilfields in the eastern and western portions of the San Joaquin Valley in Kern County to: (1) produce three-dimensional (3D) salinity maps, (2) characterize the chemical composition of groundwater and produced water, and (3) identify the extent to which fluids from oil and gas development may be moving into protected (total dissolved solids less than 10,000 milligrams per liter) groundwater at regional scales. Analysis of available salinity data near oil/gas fields indicates there are regional patterns to salinity depth profiles; however, data gaps between the depths of water and oil/gas wells are common. These results provide a foundation for more detailed oilfield-scale salinity mapping, which includes geophysical methods (borehole, surface, and airborne) to fill data gaps. The RMP sampling-well networks are designed to evaluate groundwater quality along transects from oil/gas fields into adjacent aquifers and consist of existing wells supplemented by monitoring-well installation in priority locations identified by using 3D visualization of hydrogeologic data. The analytes include constituents with different transport characteristics such as dissolved gases, inorganic components (brines), and petroleum compounds. Analytes were selected because of their potential usefulness for understanding processes and pathways by which fluids from oilfield sources reach groundwater.
NASA Astrophysics Data System (ADS)
Cino, C.; Seyfried, W. E., Jr.; Tan, C.; Fu, Q.
2017-12-01
Yellowstone National Park is a dynamic environment home to an array of geysers, hot springs, and hydrothermal vents fueled by the underlying continental magmatic intrusion. Yellowstone Lake vent fluids accounts for approximately 10% of the total geothermal flux for all of Yellowstone National Park. Though studying this remote hydrothermal system poses severe challenges, it provides an excellent natural laboratory to research hydrothermal fluids that undergo higher pressure and temperature conditions in an environment largely shielded from atmospheric oxygen. The location of these vents also provides chemistry that is characteristic of fluids deeper in the Yellowstone hydrothermal system. In August 2016, hydrothermal fluids were collected from the Stevenson Island vents in collaboration with the Hydrothermal Dynamics of Yellowstone Lake (HD-YLAKE) project using novel sampling techniques and monitoring instrumentation. The newly built ROV Yogi was deployed to reach the vents in-situ with temperatures in excess of 151oC at 100-120 m depth, equipped with a 12-cylinder isobaric sampler to collect the hydrothermal fluids. Results from geochemical analyses indicate the fluids are rich in gases such as CO2, CH4, and H2S, with sample concentrations of approximately 12 mM, 161 μm, and 2.1 mM respectively. However, lake water mixing with the hydrothermal endmember fluid likely diluted these concentrations in the collected samples. Isotopic analyses indicate CO2 has a δ13C of -6 indicating magmatic origins, however the CH4 resulted in a δ13C of -65 which is in the biological range. This biogenic signature is likely due to the pyrolysis of immature organic matter in the lake bottom sediment, since the high temperatures measured for the fluids would not allow the presence of methanogens. H2S concentrations have not been previously measured for the hydrothermal fluids in Yellowstone Lake, and our vent fluid samples indicate significantly higher H2S concentrations than reported for subaerial vents. The cause of these measured high dissolved H2S concentrations in Yellowstone Lake may result from temperature and/or redox effects.
Stridsklev, Inger Cecilie; Schaller, Karl-Heinz; Langård, Sverre
2004-11-01
This study was undertaken to investigate the exposure to chromium (Cr) and nickel (Ni) in flux-cored wire (FCW) welders welding on stainless steel (SS). Seven FCW welders were monitored for 3 days to 1 workweek, measuring Cr and Ni in air, blood, and urine. The welders were questioned about exposure to Cr and Ni during their whole working careers, with emphasis on the week of monitoring, about the use of personal protective equipment and their smoking habits. The air concentrations were mean 200 microg/m(3) (range 2.4-2,744) for total Cr, 11.3 microg/m(3) (<0.2-151.3) for Cr(VI), and 50.4 microg/m(3) (<2.0-416.7) for Ni during the workdays for the five welders who were monitored with air measurements. The levels of Cr and Ni in biological fluids varied between different workplaces. For Cr in whole blood, plasma, and erythrocytes, the mean levels after work were 1.25 (<0.4-8.3) and 1.68 (<0.2-8.0) and 0.9 (<0.4-7.2) microg/l, respectively. For Ni most of the measurements in whole blood and plasma were below the detection limits, the mean levels after work being 0.84 (<0.8-3.3) and 0.57 microg/l (<0.4-1.7), respectively. Mean levels for Cr and Ni in the urine after work were 3.96 (0.34-40.7) and 2.50 (0.56-5.0) microg/g creatinine, respectively. Correlations between the Cr(VI) levels measured in air and the levels of total Cr in the measured biological fluids were found. The results seem to support the view that monitoring of Cr in the urine may be versatile for indirect monitoring of the Cr(VI) air level in FCW welders. The results seem to suggest that external and internal exposure to Cr and Ni in FCW welders welding SS is low in general.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McCann, D.; White, D.
This paper reports on a smart alarm system installed on a number of offshore rigs and one land rig which can detect kicks more quickly than conventional systems. This rapid kick detection improves rig safety because the smaller the detected influx, the easier it is to control the well. The extensive computerized monitoring system helps drilling personnel detect fluid influxes and fluid losses before the changes in flow would normally be apparent.
Flow-Control Unit For Nitrogen And Hydrogen Gases
NASA Technical Reports Server (NTRS)
Chang, B. J.; Novak, D. W.
1990-01-01
Gas-flow-control unit installed and removed as one piece replaces system that included nine separately serviced components. Unit controls and monitors flows of nitrogen and hydrogen gases. Designed for connection via fluid-interface manifold plate, reducing number of mechanical fluid-interface connections from 18 to 1. Unit provides increasing reliability, safety, and ease of maintenance, and for reducing weight, volume, and power consumption.
STS-30 onboard view of fluids experiment apparatus (FEA) equipment
1989-05-08
STS030-10-003 (4-8 May 1989) --- An overall scene of the onboard materials science project for STS-30. Seen is the fluids experiment apparatus, supported by an accompanying computer and an 8mm camcorder for its operation. Another major component of the project-- Astronaut Mary L. Cleave, who devoted a great deal of STS-30 monitoring various experiments--is out of frame.
Metalworking fluids: oil mist and beyond.
Gauthier, Stephen L
2003-11-01
This article is based upon my own experiences with metalworking fluids and the adverse health effects and medical conditions associated with exposure to metalworking fluids. I have researched and witnessed the benefits that can be achieved when metalworking fluids are properly maintained and managed. My experiences have provided insight into how a shop operates, including comprehension of the equipment used, processes, mist generating points, engineering controls currently being adopted, and procedures that are used to maintain metalworking fluids. I have been able to share my personal experiences with the country's leading experts in the field of metalworking fluids. I have presented my insights on the topic in Washington, D.C., to the Standard Advisory Committee of OSHA, as well as at many other conferences nationwide. I have provided awareness training for a number of union and nonunion workers. Being a part of developing successful metal removal fluid programs, I realize the importance of transferring and sharing information. Many times an organization is not fully aware of certain conditions and how to combat them. My mission and intent is to properly educate those who are exposed to the harm that metalworking fluids can invoke and to inform those involved of the possible methods of reducing long- and short-term risk. One thing that must be kept in mind is the way we view these fluids. Many shops categorize the fluids as a type of "operating expense" when they should actually be seen as a sort of investment. Just as performing a scheduled maintenance on a machine promises the best possible longevity of that machine, the upkeep of metalworking fluid also provides longer "tool life." Monitoring and maintaining the fluids also provides for more effective and efficient productivity. If we fail to consider that proper management of the fluids can cut cost dramatically, then we will miss out on the financial impact they can have on a company. Try looking at the fluids as a liquid tool. Doing so I believe will bring a better understanding of the value of a successful metalworking fluids program. With this new understanding, it can be seen just who must play a role in the management of metalworking fluids. The employees who deal with the daily tasks involving the coolant play a major part. They are on the floor where these metalworking fluids are being used. In many shops, it is assumed that the environmental health & safety departments are responsible for standard operating procedures and management of fluids. The EH&S department should only be responsible for the protection from exposure and the transfer of information regarding policy and procedure to their employees. Not all shops have the resources required to develop and implement the proper standard operating procedure. Therefore, we must understand that what is feasible for one may not be for another. Companies that lack the sufficient resources should not be neglected. It is crucial that awareness of proper standard operating procedure is shared with everyone involved with the fluids in order to provide proper metalworking fluids management. Fluids are as dynamic as the formulations themselves (complex & dynamic). These fluids can quickly become contaminated with foreign materials and chemicals, thereby become aerosolized into mist. With proper education and training, one will be able to control what gets aerosolized.
Rapid, low cost prototyping of transdermal devices for personal healthcare monitoring.
Sharma, Sanjiv; Saeed, Anwer; Johnson, Christopher; Gadegaard, Nikolaj; Cass, Anthony Eg
2017-04-01
The next generation of devices for personal healthcare monitoring will comprise molecular sensors to monitor analytes of interest in the skin compartment. Transdermal devices based on microneedles offer an excellent opportunity to explore the dynamics of molecular markers in the interstitial fluid, however good acceptability of these next generation devices will require several technical problems associated with current commercially available wearable sensors to be overcome. These particularly include reliability, comfort and cost. An essential pre-requisite for transdermal molecular sensing devices is that they can be fabricated using scalable technologies which are cost effective. We present here a minimally invasive microneedle array as a continuous monitoring platform technology. Method for scalable fabrication of these structures is presented. The microneedle arrays were characterised mechanically and were shown to penetrate human skin under moderate thumb pressure. They were then functionalised and evaluated as glucose, lactate and theophylline biosensors. The results suggest that this technology can be employed in the measurement of metabolites, therapeutic drugs and biomarkers and could have an important role to play in the management of chronic diseases.
Du, Wei; Wang, Xiao-Ting; Long, Yun; Liu, Da-Wei
2017-01-01
Background: Evaluating the hemodynamic status and predicting fluid responsiveness are important in critical ultrasound assessment of shock patients. Transthoracic echocardiography with noninvasive diagnostic parameters allows the assessment of volume responsiveness. This study aimed to assess the hemodynamic changes in the liver and systemic hemodynamic changes during fluid challenge and during passive leg raising (PLR) by measuring hepatic venous flow (HVF) velocity. Methods: This is an open-label study in a tertiary teaching hospital. Shock patients with hypoperfusion who required fluid challenge were selected for the study. Patients <18 years old and those with contraindications to PLR were excluded from the study. Baseline values were measured, PLR tests were performed, and 500 ml of saline was infused over 30 min. Parameters associated with cardiac output (CO) in the left ventricular outflow tract were measured using the Doppler method. In addition, HVF velocity and right ventricular function parameters were determined. Results: Middle hepatic venous (MHV) S-wave velocity was positively correlated in all patients with CO at baseline (r = 0.706, P < 0.01) and after volume expansion (r = 0.524, P = 0.003). CO was also significantly correlated with MHV S-wave velocity in responders (r = 0.608, P < 0.01). During PLR, however, hepatic venous S-wave velocity did not correlate with CO. For the parameter ΔMHV D (increase in change in MHV D-wave velocity after volume expansion), defined as (MHV DafterVE − MHV DBaseline)/MHV DBaseline × 100%, >21% indicated no fluid responsiveness, with a sensitivity of 100%, a specificity of 71.2%, and an area under the receiver operating characteristic curve of 0.918. Conclusions: During fluid expansion, hepatic venous S-wave velocity can be used to monitor CO, whether or not it is increasing. ΔMHV D ≥21% indicated a lack of fluid responsiveness, thus helping to decide when to stop infusions. PMID:28485321
Management of Diarrhoeal Dehydration in Childhood: A Review for Clinicians in Developing Countries
Anigilaje, Emmanuel Ademola
2018-01-01
The survival of a child with severe volume depletion at the emergency department depends on the competency of the first responder to recognize and promptly treat hypovolemic shock. Although the basic principles on fluid and electrolytes therapy have been investigated for decades, the topic remains a challenge, as consensus on clinical management protocol is difficult to reach, and more adverse events are reported from fluid administration than for any other drug. While the old principles proposed by Holliday and Segar, and Finberg have stood the test of time, recent systematic reviews and meta-analyses have highlighted the risk of hyponatraemia, and hyponatraemic encephalopathy in some children treated with hypotonic fluids. In the midst of conflicting literature on fluid and electrolytes therapy, it would appear that isotonic fluids are best suitable for the correction of hypotonic, isonatraemic, and hypernatraemic dehydration. Although oral rehydration therapy is adequate to correct mild to moderate isonatraemic dehydration, parenteral fluid therapy is safer for the child with severe dehydration and those with changes in serum sodium. The article reviews the pathophysiology of water and sodium metabolism and, it uses the clinical case examples to illustrate the bed-side approach to the management of three different types of dehydration using a pre-mixed isotonic fluid solution (with 20 or 40 mmol/L of potassium chloride added depending on the absence or presence of hypokalemia, respectively). When 3% sodium chloride is unavailable to treat hyponatraemic encephalopathy, 0.9% sodium chloride becomes inevitable, albeit, a closer monitoring of serum sodium is required. The importance of a keen and regular clinical and laboratory monitoring of a child being rehydrated is emphasized. The article would be valuable to clinicians in less-developed countries, who must use pre-mixed fluids, and who often cannot get some suitable rehydrating solutions. PMID:29527518
NASA Astrophysics Data System (ADS)
Sendula, E.; Lamadrid, H. M.; Bodnar, R. J.
2017-12-01
Ultramafic and mafic rocks (e.g. peridotites, serpentinites and basalts) are being considered as possible targets for CO2 sequestration via mineral carbonation. The determination of reaction kinetics and the factors that control mineralization are important in order to understand and predict fluid-rock reactions between the injected CO2 and the host rocks. Here we present results of experiments focused on determining the reaction rates of carbonation of olivine as a function of initial CO2 concentration (20 mol% and 11 mol%) in the aqueous solution and temperature (100°C and 50°C). We used a recently developed experimental method (Lamadrid et al., 2017) that uses synthetic fluid inclusions as micro-reactors. The micro-reactor technique coupled with non-destructive Raman spectroscopy allows us to monitor the reaction progress in situ and in real time, by quantifying the amount of CO2 consumed in the reaction as a function of time. Results show a measurable decrease of CO2 density in the fluid inclusions as a result of the reaction between the CO2-bearing aqueous phase and olivine. Magnesite formation begins within several hours at 100°C and most of the CO2 was consumed within two days. At 50°C, however, magnesite nucleation and precipitation required weeks to months to begin, and the reaction rates were about an order of magnitude slower than in the experiments at 100°C. No significant differences were observed in the reaction rates as a function of initial CO2 concentration. The application of the synthetic fluid inclusion technique as micro-reactors coupled with non-destructive analytical techniques is a promising tool to monitor rates of fluid-rock reactions in situ and in real time, allowing detailed micron-scale investigations. The technique can be applied to a wide variety of chemical systems, host minerals, reaction products, fluid densities, temperatures, and different starting fluid compositions.
Youngquist, Tiffany M; Richardson, C Peter; Diblasi, Robert M
2013-11-01
Bubble CPAP is frequently used in spontaneously breathing infants with lung disease. Often bubble CPAP systems lack pressure alarms and pressure-release valves. We observed a large volume of condensate in the exhalation limb of a patient circuit and conducted a series of experiments to test the hypothesis that accumulated condensate could affect delivered pressures. An anatomically accurate nasal airway model of a preterm infant was attached to a spontaneously breathing lung model. A bubble CPAP system was attached to the nasal airway with bi-nasal short prongs, and the rate of fluid condensation was measured. Next, tracheal pressures were monitored digitally to detect changes in airway pressure related to condensate accumulation. Measurements were obtained with volumes of 0, 5, 10, 15, and 20 mL of water in the exhalation limb, at flows of 4, 6, 8, and 10 L/min. Measurements with 20 mL in the exhalation limb were recorded with and without a pressure-relief valve in the circuit. The rate of condensate accumulation was 3.8 mL/h. At volumes of ≥ 10 mL, noticeable alterations in the airway pressure waveforms and significant increases in mean tracheal pressure were observed. The pressure-relief valve effectively attenuated peak tracheal pressure, but only decreased mean pressure by 0.5-1.5 cm H2O. Condensate in the exhalation limb of the patient circuit during bubble CPAP can significantly increase pressure delivered to the patient. The back and forth movement of this fluid causes oscillations in airway pressure that are much greater than the oscillations created by gas bubbling out the exhalation tube into the water bath. We recommend continuously monitoring pressure at the nasal airway interface, placing an adjustable pressure-relief valve in the circuit, set to 5 cm H2O above the desired mean pressure, and emptying fluid from the exhalation limb every 2-3 hours.
Underwater robot society doing internal inspection and leak monitoring of water systems
NASA Astrophysics Data System (ADS)
Halme, Aarne; Vainio, Mika; Appelqvist, Pekka; Jakubik, Peter; Schonberg, Torsten; Visala, Arto
1997-09-01
In the field of civil engineering an effective internal monitoring of pipes and water storage is very problematic. Normally the sensors used for the task are either fixed or manually movable. Thus they will only provide locally and temporally restricted information. As a solution an underwater robotic sensor/actuator society is presented. The system is capable of operating inside a fluid environment as a kind of distributed sensory system. The value of the system emerges from the interactions between the members. Through a communication system the society fuses information from individual members and provides a more reliable estimate of the conditions inside water systems. Tests results in a transparent demo process consisting of tanks and pipes with a volume of 700 liters are presented.
Blennow, Kaj; Zetterberg, Henrik
2015-01-01
This paper gives a short review on cerebrospinal fluid (CSF) biomarkers for Alzheimer's disease (AD), from early developments to high-precision validated assays on fully automated lab analyzers. We also discuss developments on novel biomarkers, such as synaptic proteins and Aβ oligomers. Our vision for the future is that assaying a set of biomarkers in a single CSF tube can monitor the whole spectrum of AD molecular pathogenic events. CSF biomarkers will have a central position not only for clinical diagnosis, but also for the understanding of the sequence of molecular events in the pathogenic process underlying AD and as tools to monitor the effects of novel drug candidates targeting these different mechanisms.
Water: an essential but overlooked nutrient.
Kleiner, S M
1999-02-01
Water is an essential nutrient required for life. To be well hydrated, the average sedentary adult man must consume at least 2,900 mL (12 c) fluid per day, and the average sedentary adult woman at least 2,200 mL (9 c) fluid per day, in the form of noncaffeinated, nonalcoholic beverages, soups, and foods. Solid foods contribute approximately 1,000 mL (4 c) water, with an additional 250 mL (1 c) coming from the water of oxidation. The Nationwide Food Consumption Surveys indicate that a portion of the population may be chronically mildly dehydrated. Several factors may increase the likelihood of chronic, mild dehydration, including a poor thirst mechanism, dissatisfaction with the taste of water, common consumption of the natural diuretics caffeine and alcohol, participation in exercise, and environmental conditions. Dehydration of as little as 2% loss of body weight results in impaired physiological and performance responses. New research indicates that fluid consumption in general and water consumption in particular can have an effect on the risk of urinary stone disease; cancers of the breast, colon, and urinary tract; childhood and adolescent obesity; mitral valve prolapse; salivary gland function; and overall health in the elderly. Dietitians should be encouraged to promote and monitor fluid and water intake among all of their clients and patients through education and to help them design a fluid intake plan. The influence of chronic mild dehydration on health and disease merits further research.
The Effect of Borehole Flow on Salinity Profiles From Deep Monitor Wells in Hawaii
NASA Astrophysics Data System (ADS)
Rotzoll, K.; Hunt, C. D.; El-Kadi, A. I.
2008-12-01
Ground-water resource management in Hawaii is based partly on salinity profiles from deep wells that are used to monitor the thickness of freshwater lenses and the transition zone between freshwater and saltwater. Vertical borehole flow in these wells may confound understanding of the actual salinity-depth profiles in the basaltic aquifers and lead to misinterpretations that hamper effective water-resource management. Causes and effects of borehole flow on salinity profiles are being evaluated at 40 deep monitor wells in Hawaii. Step- like changes in fluid electrical conductivity with respect to depth are indicative of borehole flow and are evident in almost all available salinity profiles. A regional trend in borehole flow direction, expected from basin-wide ground-water flow dynamics, is evident as major downward flow components in inland recharge areas and major upward flow components in discharge areas near the coast. The midpoint of the transition zone in one deep monitor well showed inconsequential depth displacements in response to barometric pressure and tidal fluctuations and to pumping from nearby wellfields. Commonly, the 1 mS/cm conductivity value is used to indicate the top of the transition zone. Contrary to the more stable midpoint, the depth of the 1 mS/cm conductivity value may be displaced by as much as 200 m in deep monitor wells near pumping wellfields. The displacement is complemented with an increase in conductivity at a particular depth in the upper part of the profile. The observed increase in conductivity is linear with increase in nearby pumpage. The largest deviations from expected aquifer-salinity profiles occur in deep monitor wells located in the area extending from east Pearl Harbor to Kalihi on Oahu, which coincides with the most heavily pumped part of the aquifer.
NASA Astrophysics Data System (ADS)
Gülşen, Esra; Kurtulus, Bedri; Necati Yaylim, Tolga; Avsar, Ozgur
2017-04-01
In groundwater studies, quantification and detection of fluid flows in borehole is an important part of assessment aquifer characteristic at different depths. Monitoring wells disturbs the natural flow field and this disturbance creates different flow paths to an aquifer. Vertical flow fluid analyses are one of the important techniques to deal with the detection and quantification of these vertical flows in borehole/monitoring wells. Liwa region is located about 146 km to the south west of Abu Dhabi city and about 36 km southwest of Madinat Zayed. SWSR (Strategic Water Storage & Recovery Project) comprises three Schemes (A, B and C) and each scheme contains an infiltration basin in the center, 105 recovery wells, 10 clusters and each cluster comprises 3 monitoring wells with different depths; shallow ( 50 m), intermediate ( 75 m) and deep ( 100 m). The scope of this study is to calculate the transmissivity values at different depth and evaluate the Fluid Flow Log (FFL) data for Scheme A (105 recovery wells) in order to understand the aquifer characteristic at different depths. The transmissivity values at different depth levels are calculated using Razack and Huntley (1991) equation for vertical flow rates of 30 m3 /h, 60 m3 /h, 90 m3 /h, 120 m3 /h and then Empirical Bayesian Kriging is used for interpolation in Scheme A using ArcGIS 10.2 software. FFL are drawn by GeODin software. Derivative analysis of fluid flow data are done by Microsoft Office: Excel software. All statistical analyses are calculated by IBMSPSS software. The interpolation results show that the transmissivity values are higher at the top of the aquifer. In other word, the aquifer is found more productive at the upper part of the Liwa aquifer. We are very grateful for financial support and providing us the data to ZETAS Dubai Inc.
A device for real-time live-cell microscopy during dynamic dual-modal mechanostimulation
NASA Astrophysics Data System (ADS)
Lorusso, D.; Nikolov, H. N.; Chmiel, T.; Beach, R. J.; Sims, S. M.; Dixon, S. J.; Holdsworth, D. W.
2017-03-01
Mechanotransduction - the process by which cells sense and respond to mechanical stimuli - is essential for several physiological processes including skeletal homeostasis. Mammalian cells are thought to be sensitive to different modes of mechanical stimuli, including vibration and fluid shear. To better understand the mechanisms underlying the early stages of mechanotransduction, we describe the development of devices for mechanostimulation (by vibration and fluid shear) of live cells that can be integrated with real-time optical microscopy. The integrated system can deliver up to 3 Pa of fluid shear simultaneous with high-frequency sinusoidal vibrations up to 1 g. Stimuli can be applied simultaneously or independently to cells during real-time microscopic imaging. A custom microfluidic chamber was prepared from polydimethylsiloxane on a glass-bottom cell culture dish. Fluid flow was applied with a syringe pump to induce shear stress. This device is compatible with a custom-designed motion control vibration system. A voice coil actuates the system that is suspended on linear air bushings. Accelerations produced by the system were monitored with an on-board accelerometer. Displacement was validated optically using particle tracking digital high-speed imaging (1200 frames per second). During operation at nominally 45 Hz and 0.3 g, displacements were observed to be within 3.56% of the expected value. MC3T3-E1 osteoblast like cells were seeded into the microfluidic device and loaded with the calcium sensitive fluorescent probe fura-2, then mounted onto the dual-modal mechanostimulation platform. Cells were then imaged and monitored for fluorescence emission. In summary, we have developed a system to deliver physiologically relevant vibrations and fluid shear to live cells during real-time imaging and photometry. Monitoring the behavior of live cells loaded with appropriate fluorescent probes will enable characterization of the signals activated during the initial stages of mechanotransduction.
Combined Volatolomics for Monitoring of Human Body Chemistry
Broza, Yoav Y.; Zuri, Liat; Haick, Hossam
2014-01-01
Analysis of volatile organic compounds (VOCs) is a promising approach for non-invasive, fast and potentially inexpensive diagnostics. Here, we present a new methodology for profiling the body chemistry by using the volatile fraction of molecules in various body fluids. Using mass spectrometry and cross-reactive nanomaterial-based sensors array, we demonstrate that simultaneous VOC detection from breath and skin would provide complementary, non-correlated information of the body's volatile metabolites profile. Eventually with further wide population validation studies, such a methodology could provide more accurate monitoring of pathological changes compared to the information provided by a single body fluid. The qualitative and quantitative methods presented here offers a variety of options for novel mapping of the metabolic properties of complex organisms, including humans. PMID:24714440
Combined volatolomics for monitoring of human body chemistry.
Broza, Yoav Y; Zuri, Liat; Haick, Hossam
2014-04-09
Analysis of volatile organic compounds (VOCs) is a promising approach for non-invasive, fast and potentially inexpensive diagnostics. Here, we present a new methodology for profiling the body chemistry by using the volatile fraction of molecules in various body fluids. Using mass spectrometry and cross-reactive nanomaterial-based sensors array, we demonstrate that simultaneous VOC detection from breath and skin would provide complementary, non-correlated information of the body's volatile metabolites profile. Eventually with further wide population validation studies, such a methodology could provide more accurate monitoring of pathological changes compared to the information provided by a single body fluid. The qualitative and quantitative methods presented here offers a variety of options for novel mapping of the metabolic properties of complex organisms, including humans.
NASA Astrophysics Data System (ADS)
Baker, G. S.; Wu, Y.; Hubbard, S. S.; Wu, W.; Gaines, D. P.; Pratt, J. C.; Modi, A. L.; Watson, D.; Jardine, P.
2009-05-01
We present results from surface time-lapse electrical resistivity tomography (TLERT) data collected within a uranium-contaminated unconfined aquifer underlying the Oak Ridge Field Research Center (ORFRC) located at the Oak Ridge National Laboratory (ORNL) in Tennessee. As part of an Integrated Field Research Challenge (IFRC) project supported by the DOE Environmental Remediation Sciences Program (ERSP), bioreduction of U(VI) to U(IV) with ethanol as an electron donor has been tested during the last four years. Low U concentration (below US EPA MCL of 0.03 mg/L) can be achieved by frequent injection of electron donor. To reduce the costs and improve the sustainability for remediation and site maintenance, our IFRC team is exploring the effectiveness of a slowly degrading substrate such as commercial emulsified vegetable oil substrate (EVO) as alternative electron donor sources. Laboratory batch and flow-through column experiments were carried out to investigate the sensitivity of various physical properties (e.g., electrical conductivity) to EVO injection to test the applicability of geophysics as a monitoring tool at the field scale. Results revealed increased electrical conductivity during both EVO injection and subsequent degradation of surfactant with an overall increase in conductivity of ˜35%; thus, surface TLERT was selected as a monitoring tool to supplement well fluid samples. The field stimulation test began at Area 2 during early February 2009. Prior to the injection of the EVO, preliminary characterization completed, including a geochemical survey of the ground water from ˜50 wells, microbial samples of groundwater and sediment collected from selected wells, and site hydrology characterized by bromide tracer test and surface ERT methods. On February 9, 2009, diluted EVO solution (20% concentration, 900 gal vol) was injected into three injection wells within 1.5 hours. Distribution of the injected EVO and accompanying biogeochemical processes has been monitored since injection through analysis of numerous well fluid samples and TLERT data from 2 profiles. Initial TLERT data were collected at the 2 profiles over a two-week period at 12 different time steps. The surface profiles, situated parallel to and perpendicular to the major flow direction (as delineated by tracer tests), are each 40 m long and consist of 52 electrodes spaced at 0.75 m. Initial analysis indicate good correlation between well fluid samples and TLERT data and allow for improved extrapolation of well data to the field scale. Long-term monitoring is in place to track the continuing hydrologic dynamics and reduction duration in this test area throughout Spring 2009.
NASA Astrophysics Data System (ADS)
Jougnot, Damien; Jiménez-Martínez, Joaquín; Legendre, Raphaël; Le Borgne, Tanguy; Méheust, Yves; Linde, Niklas
2018-03-01
Time-lapse electrical resistivity tomography (ERT) is a geophysical method widely used to remotely monitor the migration of electrically-conductive tracers and contaminant plumes in the subsurface. Interpretations of time-lapse ERT inversion results are generally based on the assumption of a homogeneous solute concentration below the resolution limits of the tomogram depicting inferred electrical conductivity variations. We suggest that ignoring small-scale solute concentration variability (i.e., at the sub-resolution scale) is a major reason for the often-observed apparent loss of solute mass in ERT tracer studies. To demonstrate this, we developed a geoelectrical milli-fluidic setup where the bulk electric conductivity of a 2D analogous porous medium, consisting of cylindrical grains positioned randomly inside a Hele-Shaw cell, is monitored continuously in time while saline tracer tests are performed through the medium under fully and partially saturated conditions. High resolution images of the porous medium are recorded with a camera at regular time intervals, and provide both the spatial distribution of the fluid phases (aqueous solution and air), and the saline solute concentration field (where the solute consists of a mixture of salt and fluorescein, the latter being used as a proxy for the salt concentration). Effective bulk electrical conductivities computed numerically from the measured solute concentration field and the spatial distributions of fluid phases agree well with the measured bulk conductivities. We find that the effective bulk electrical conductivity is highly influenced by the connectivity of high electrical conductivity regions. The spatial distribution of air, saline tracer fingering, and mixing phenomena drive temporal changes in the effective bulk electrical conductivity by creating preferential paths or barriers for electrical current at the pore-scale. The resulting heterogeneities in the solute concentrations lead to strong anisotropy of the effective bulk electrical conductivity, especially for partially saturated conditions. We highlight how these phenomena contribute to the typically large apparent mass loss observed when conducting field-scale time-lapse ERT.
Wireless Fluid-Level Measurement System Equips Boat Owners
NASA Technical Reports Server (NTRS)
2008-01-01
While developing a measurement acquisition system to be used to retrofit aging aircraft with vehicle health monitoring capabilities, Langley Research Center developed an innovative wireless fluid-level measurement system. The NASA technology was of interest to Tidewater Sensors LLC, of Newport News, Virginia, because of its many advantages over conventional fuel management systems, including its ability to provide an accurate measurement of volume while a boat is experiencing any rocking motion due to waves or people moving about on the boat. These advantages led the company to license this novel fluid-level measurement system from NASA for marine applications.
40 CFR 60.734 - Monitoring of emissions and operations.
Code of Federal Regulations, 2010 CFR
2010-07-01
... operator of an affected facility subject to the provisions of this subpart who uses a dry control device to... control device. (b) In lieu of a continuous opacity monitoring system, the owner or operator of a ball... vermiculite fluid bed dryer, or a vermiculite rotary dryer who uses a dry control device may have a certified...
Benzoin Condensation: Monitoring a Chemical Reaction by High-Pressure Liquid Chromatography
ERIC Educational Resources Information Center
Bhattacharya, Apurba; Purohit, Vikram C.; Bellar, Nicholas R.
2004-01-01
High-pressure liquid chromatography (HPLC) is the preferred method of separating a variety of materials in complex mixtures such as pharmaceuticals, polymers, soils, food products and biological fluids and is also considered to be a powerful analytical tool in both academia and industry. The use of HPLC analysis as a means of monitoring and…
Flow monitoring and control system for injection wells
Corey, J.C.
1991-01-01
The present invention relates to a system for monitoring and controlling the rate of fluid flow from an injection well used for in-situ remediation of contaminated groundwater. The United States Government has rights in this invention pursuant to Contract No. DE-AC09-89SR18035 between the US Department of Energy and Westinghouse Savannah River Company.
Ishikawa, Naoyoshi; Miyata, Toshio; Ueda, Yasuhiko; Inagi, Reiko; Izuhara, Yuko; Yuzawa, Hiroko; Onogi, Hiroshi; Nishina, Makoto; Nangaku, Masaomi; Van Ypersele De Strihou, Charles; Kurokawa, Kiyoshi
2003-01-01
Reactive carbonyl compounds (RCOs) present in peritoneal dialysis (PD) fluid have been incriminated in the progressive deterioration of the peritoneal membrane in long-term PD patients. They are initially present in fresh conventional heat-sterilized glucose PD fluid and are supplemented during dwell time by the diffusion of blood RCOs within the peritoneal cavity. In the present study, RCO entrapping agents were immobilized on affinity beads to adsorb RCOs both in fresh PD fluid and in PD effluent. The RCO trapping potential of various compounds was assessed in vitro first by dissolving them in the tested fluid and subsequently after coupling with either epoxy- or amino-beads. The tested fluids include fresh heat-sterilized glucose and non-glucose PD fluids, and PD effluent. Their RCOs contents, that is, glyoxal (GO), methylglyoxal (MGO), 3-deoxyglucosone (3-DG), formaldehyde, 5-hydroxymethylfuraldehyde, acetaldehyde, and 2-furaldehyde were monitored by reverse-phase high-pressure liquid chromatography. The biocompatibility of PD fluid was assessed by a cytotoxic assay with either human epidermoid cell line A431 cells or with primary cultured human peritoneal mesothelial cells. Among the tested RCO entrapping agents, hydrazine coupled to epoxy-beads proved the most efficient. It lowered the concentrations of three dicarbonyl compounds (GO, MGO, and 3-DG) and those of aldehydes present in fresh heat-sterilized glucose PD fluid toward the low levels observed in filter-sterilized glucose PD fluid. It did not change the glucose and electrolytes concentration of the PD fluid but raised its pH from 5.2 to 5.9. Hydrazine-coupled epoxy-bead also lowered the PD effluent content of total RCOs, measured by the 2,4-dinitrophenylhydrazone (DNPH) method. The cytotoxicity of heat-sterilized PD fluid incubated with hydrazine-coupled epoxy-beads was decreased to the level observed in filter-sterilized PD fluid as the result of the raised pH and the lowered RCOs levels. Hydrazine-coupled epoxy-beads reduce the levels of a variety of dicarbonyls and aldehydes present in heat-sterilized glucose PD fluid to those in filter-sterilized PD fluid, without altering glucose, lactate, and electrolytes contents but with a rise in pH. Incubated with PD effluents, it is equally effective in reducing the levels of serum-derived RCOs. RCO entrapping agents immobilized on affinity beads improve in vitro the biocompatibility of conventional heat-sterilized glucose PD fluid. Their clinical applicability requires further studies.
Breuer, Jan-P; von Dossow, Vera; von Heymann, Christian; Griesbach, Markus; von Schickfus, Michael; Mackh, Elise; Hacker, Cornelia; Elgeti, Ulrike; Konertz, Wolfgang; Wernecke, Klaus-D; Spies, Claudia D
2006-11-01
In this study we investigated the effects of preoperative oral carbohydrate administration on postoperative insulin resistance (PIR), gastric fluid volume, preoperative discomfort, and variables of organ dysfunction in ASA physical status III-IV patients undergoing elective cardiac surgery, including those with noninsulin-dependent Type-2 diabetes mellitus. Before surgery, 188 patients were randomized to receive a clear 12.5% carbohydrate drink (CHO), flavored water (placebo), or to fast overnight (control). CHO and placebo were treated in double-blind format and received 800 mL of the corresponding beverage in the evening and 400 mL 2 h before surgery. Patients were monitored from induction of general anesthesia until 24 h postoperatively. Exogenous insulin requirements to control blood glucose levels
Oxygen Mass Flow Rate Generated for Monitoring Hydrogen Peroxide Stability
NASA Technical Reports Server (NTRS)
Ross, H. Richard
2002-01-01
Recent interest in propellants with non-toxic reaction products has led to a resurgence of interest in hydrogen peroxide for various propellant applications. Because peroxide is sensitive to contaminants, material interactions, stability and storage issues, monitoring decomposition rates is important. Stennis Space Center (SSC) uses thermocouples to monitor bulk fluid temperature (heat evolution) to determine reaction rates. Unfortunately, large temperature rises are required to offset the heat lost into the surrounding fluid. Also, tank penetration to accomodate a thermocouple can entail modification of a tank or line and act as a source of contamination. The paper evaluates a method for monitoring oxygen evolution as a means to determine peroxide stability. Oxygen generation is not only directly related to peroxide decomposition, but occurs immediately. Measuring peroxide temperature to monitor peroxide stability has significant limitations. The bulk decomposition of 1% / week in a large volume tank can produce in excess of 30 cc / min. This oxygen flow rate corresponds to an equivalent temperature rise of approximately 14 millidegrees C, which is difficult to measure reliably. Thus, if heat transfer were included, there would be no temperature rise. Temperature changes from the surrounding environment and heat lost to the peroxide will also mask potential problems. The use of oxygen flow measurements provides an ultra sensitive technique for monitoring reaction events and will provide an earlier indication of an abnormal decomposition when compared to measuring temperature rise.
NASA Astrophysics Data System (ADS)
Olivares, L.; Tommasi, P.; Madonia, P.; Moretti, R.
2012-04-01
The stability of steep ( > 40°) slopes in loose or poorly cemented pyroclastic materials mantling some of the Italian mountain areas is guaranteed by the positive effects of matrix suction on shear strength until an increase in saturation (and hence a decrease in suction) occurs. Therefore, unsaturated cohesionless or slightly-bonded pyroclastic steep deposits are relatively stable. Slope instability, initiated by wetting, can occur through different processes, such as vapor condensation and, most typically, rainfall infiltration. The main effect is the decrease in suction up to possible development of positive pore pressures. Here, we examine the peculiar case of a landslide on the flank of the pyroclastic cone of La Fossa volcanic edifice in Vulcano Island (Aeolian Archipelago, Southern Italy). Its initiation is believed to have been influenced by a sharp increase in condensed vapor produced by the degassing of the active volcano. In active volcanoes hydraulic conditions are affected not only by infiltrating rainwater but also by volcanic activity, which produces complex changes in the state variables of pore fluids (i.e. pore fluid pressure). In particular, volcanic activity can modify pore fluid pressure as far as to induce slope instability. At La Fossa crater the phenomenon was evidenced by in situ monitoring of soil suction and soil temperature. In situ observations and measurements indicate that seepage of condensed vapor is appreciable. Simple models based on the geotechnical characterization of pyroclastic materials suggest the hypothesis that variations in suction can be significant to stability of volcano slopes when these are very close to limit conditions and if material hydraulic anisotropy is considered. Noteworthy, at La Fossa at Vulcano Island steam condensation increased and variations of chemical ratios at fumaloles occurred while large slope movements developed on the NE flank of the cone during the most intense well documented volcanic unrest. The validation of this hypothesis requires further monitoring data during periods of intense unrest and more comprehensive models that account for non-isothermal multiphase pore fluid pressure and groundwater circulation, influencing the state of stress and hence stability. Our in-progress approach points toward a correlation between degassing activity of the hydrothermal-magmatic system and slope movements, that may bear significant implications for the definition of the scenarios of joint volcanic-hydrogeological hazard and for the development of monitoring techniques in the frame of volcanic surveillance. However, much more efforts are needed to establish phenomenological relationships with the budgets of volcanic steam condensation. This should include extensive field measurement of CO2 and thermal fluxes from the soil, as well as electrical measurements.
Nanoparticle monolayers under stress: mechanically forced desorption from a fluid-fluid interface
NASA Astrophysics Data System (ADS)
Garbin, Valeria; Crocker, John C.; Stebe, Kathleen J.
2011-11-01
Nanoparticle-laden interfaces are studied for applications to materials with tunable electronic and optical properties, as emulsion stabilizers, and in catalysis. The mechanical response of nanoparticle monolayers under applied stress is of emerging interest since it impacts the success of these applications. Here we focus on the response of nanoparticle-laden interfaces to compression. A monolayer of nanoparticles is allowed to spontaneously form by adsorption from an aqueous suspension onto a pendant drop of oil. The effective surface pressure Π of the composite interface is monitored by pendant drop tensiometry. As the drop is compressed, the nanoparticles are mechanically forced out of the interface into the aqueous phase. A new optical method is developed to measure the nanoparticle area density in situ. We show that desorption occurs at a coverage that corresponds to close packing of the ligand-capped particles, suggesting that ligand-induced repulsion plays a crucial role in the desorption process.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vasco, D.W.; Rucci, A.; Ferretti, A.
2009-10-15
Interferometric Synthetic Aperture Radar (InSAR), gathered over the In Salah CO{sub 2} storage project in Algeria, provides an early indication that satellite-based geodetic methods can be effective in monitoring the geological storage of carbon dioxide. An injected volume of 3 million tons of carbon dioxide, from one of the first large-scale carbon sequestration efforts, produces a measurable surface displacement of approximately 5 mm/year. Using geophysical inverse techniques we are able to infer flow within the reservoir layer and within a seismically detected fracture/ fault zone intersecting the reservoir. We find that, if we use the best available elastic Earth model,more » the fluid flow need only occur in the vicinity of the reservoir layer. However, flow associated with the injection of the carbon dioxide does appear to extend several kilometers laterally within the reservoir, following the fracture/fault zone.« less
Method and apparatus for testing surface characteristics of a material
NASA Technical Reports Server (NTRS)
Johnson, David L. (Inventor); Kersker, Karl D. (Inventor); Stratton, Troy C. (Inventor); Richardson, David E. (Inventor)
2006-01-01
A method, apparatus and system for testing characteristics of a material sample is provided. The system includes an apparatus configured to house the material test sample while defining a sealed volume against a surface of the material test sample. A source of pressurized fluid is in communication with, and configured to pressurize, the sealed volume. A load applying apparatus is configured to apply a defined load to the material sample while the sealed volume is monitored for leakage of the pressurized fluid. Thus, the inducement of surface defects such as microcracking and crazing may be detected and their effects analyzed for a given material. The material test samples may include laminar structures formed of, for example, carbon cloth phenolic, glass cloth phenolic, silica cloth phenolic materials or carbon-carbon materials. In one embodiment the system may be configured to analyze the material test sample while an across-ply loading is applied thereto.
A novel muon detector for borehole density tomography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bonneville, Alain; Kouzes, Richard T.; Yamaoka, Jared
Muons can be used to image the density of materials through which they pass, including geological structures. Subsurface applications of the technology include tracking fluid migration during injection or production, with increasing concern regarding such timely issues as induced seismicity or chemical leakage into aquifers. Geological carbon storage, natural gas storage, enhanced oil recovery, compressed air storage, aquifer storage and recovery, waste water storage and oil and gas production are examples of application areas. It is thus crucial to monitor in quasi-real time the behavior of these fluids, and several monitoring techniques can be used. Among them, those that trackmore » density changes in the subsurface are the most relevant. Current density monitoring options include gravimetric data collection and active or passive seismic surveys. One alternative, or complement, to these methods is the development of a muon detector that is sufficiently compact and robust for deployment in a borehole. Such a muon detector can enable tomographic imaging of density structure to monitor small changes in density – a proxy for fluid migration – at depths up to 1500 m. Such a detector has been developed, and Monte Carlo modeling methods applied to simulate the anticipated detector response. The robustness of the detector design comes primarily from the use of polystyrene scintillating rods arrayed in alternating layers to provide a coordinate scheme. Testing and measurements using a prototype detector in the laboratory and shallow underground facilities demonstrated robust response. A satisfactory comparison with a large drift tube-based muon detector is also presented.« less
Wearable physiological systems and technologies for metabolic monitoring.
Gao, Wei; Brooks, George A; Klonoff, David C
2018-03-01
Wearable sensors allow continuous monitoring of metabolites for diabetes, sports medicine, exercise science, and physiology research. These sensors can continuously detect target analytes in skin interstitial fluid (ISF), tears, saliva, and sweat. In this review, we will summarize developments on wearable devices and their potential applications in research, clinical practice, and recreational and sporting activities. Sampling skin ISF can require insertion of a needle into the skin, whereas sweat, tears, and saliva can be sampled by devices worn outside the body. The most widely sampled metabolite from a wearable device is glucose in skin ISF for monitoring diabetes patients. Continuous ISF glucose monitoring allows estimation of the glucose concentration in blood without the pain, inconvenience, and blood waste of fingerstick capillary blood glucose testing. This tool is currently used by diabetes patients to provide information for dosing insulin and determining a diet and exercise plan. Similar technologies for measuring concentrations of other analytes in skin ISF could be used to monitor athletes, emergency responders, warfighters, and others in states of extreme physiological stress. Sweat is a potentially useful substrate for sampling analytes for metabolic monitoring during exercise. Lactate, sodium, potassium, and hydrogen ions can be measured in sweat. Tools for converting the concentrations of these analytes sampled from sweat, tears, and saliva into blood concentrations are being developed. As an understanding of the relationships between the concentrations of analytes in blood and easily sampled body fluid increases, then the benefits of new wearable devices for metabolic monitoring will also increase.
Conger, Randall W.; Bird, Philip H.
1999-01-01
Between May and July 1998, 10 monitor wells were drilled near the site of the former Naval Air Warfare Center (NAWC), Warminster, Bucks County, Pa., to monitor water levels and sample ground water in shallow and intermediate water-bearing fractures. The sampling will determine the horizontal and vertical distribution of contaminated ground water migrating from known or suspected sources. Three boreholes were drilled on the property at 960 Jacksonville Road, at the northwestern side of NAWC, along strike from Area A; seven boreholes were drilled in Area B in the southeastern corner of NAWC. Depths range from 40.5 to 150 feet below land surface.Borehole geophysical logging and video surveys were used to identify water-bearing fractures so that appropriate intervals could be screened in each monitor well. Geophysical logs were obtained at the 10 monitor wells. Video surveys were obtained at three monitor wells in the southeastern corner of the NAWC property.Caliper logs and video surveys were used to locate fractures. Inflections on fluid-temperature and fluid-resistivity logs were used to locate possible water-bearing fractures. Heatpulse-flowmeter measurements verified these locations. Natural-gamma logs provided information on stratigraphy. After interpretation of geophysical logs, video surveys, and driller's logs, all wells were screened such that water-level fluctuations could be monitored and water samples collected from discrete water-bearing fractures in each monitor well.
Multishell encapsulation using a triple coaxial electrospray system.
Kim, Woojin; Kim, Sang Soo
2010-06-01
To overcome the limitations of the conventional encapsulation methods and improve the potential use of the electrospray method as a drug delivery system, an electrospray system using a triple coaxial nozzle was developed to generate multishell capsules. Two conducting fluids, ethylene glycol and 4-hydroxybutyl acrylate, and one nonconducting fluid, olive oil, were chosen to manufacture the multishell capsules. The capsules were solidified by a photopolymerization device. We investigated the size distributions and visualized the capsules changing fluid flow rates. Dispersive Raman spectra were also monitored to determine the chemical composition of the capsules. The multishell capsules were generated in the overlapped cone-jet mode regime of the conducting fluids, and the sizes and shell thicknesses were controlled by the flow rates and applied voltages.
Real Time Oil Reservoir Evaluation Using Nanotechnology
NASA Technical Reports Server (NTRS)
Li, Jing (Inventor); Meyyappan, Meyya (Inventor)
2011-01-01
A method and system for evaluating status and response of a mineral-producing field (e.g., oil and/or gas) by monitoring selected chemical and physical properties in or adjacent to a wellsite headspace. Nanotechnology sensors and other sensors are provided for one or more underground (fluid) mineral-producing wellsites to determine presence/absence of each of two or more target molecules in the fluid, relative humidity, temperature and/or fluid pressure adjacent to the wellsite and flow direction and flow velocity for the fluid. A nanosensor measures an electrical parameter value and estimates a corresponding environmental parameter value, such as water content or hydrocarbon content. The system is small enough to be located down-hole in each mineral-producing horizon for the wellsite.
Warnakulasuriya, Samantha R; Davies, Simon J; Wilson, R Jonathan T; Yates, David R A
2016-11-01
This study aims to investigate if there is equivalence in volumes of fluid administered when intravenous fluid therapy is guided by Pleth Variability Index (PVI) compared to the established technology of esophageal Doppler in low-risk patients undergoing major colorectal surgery. Randomized controlled trial. Operating room. Forty low-risk patients undergoing elective colorectal surgery. Patients were monitored by esophageal Doppler and PVI probes and were randomized to have fluid therapy directed by using one of these technologies, with 250 mL boluses of colloid to maintain a maximal stroke volume, or a PVI of less than 14%. Absolute volumes of fluid volumes given intraoperatively were measured as were 24 hours fluid volumes. Perioperative measurements of lactate and base excess were recorded as were postoperative complications. There was no significant difference between PVI and esophageal Doppler groups in mean total fluid administered (1286 vs 1520 mL, P=.300) or mean intraoperative fluid balance (+839 v+1145 mL, P=.150). PVI offers an entirely non-invasive alternative for goal-directed fluid therapy in this group of patients. Copyright © 2016 Elsevier Inc. All rights reserved.
... return the body temperature to normal Monitoring any excess fluid in older people with heart or kidney disease Medicines to manage agitation Vitamins and glucose The final goal of treatment is ...
NASA Astrophysics Data System (ADS)
Lisabeth, H. P.; Zoback, M. D.
2017-12-01
Understanding the flow of fluids through fractures in clay-rich rocks is fundamental to a number of geoengineering enterprises, including development of unconventional hydrocarbon resources, nuclear waste storage and geological carbon sequestration. High clay content tends to make rocks plastic, low-porosity and anisotropic. In addition, some gasses adsorb to clay mineral surfaces, resulting in swelling and concomitant changes in physical properties. These complexities can lead to coupled behaviors that render prediction of fluid behavior in the subsurface difficult. We present the results of a suite of triaxial experiments on binary mixtures of quartz and illite grains to separate and quantify the effects of hydrostatic pressure, differential stress, clay content and gas chemistry on the evolution of mechanical and hydraulic characteristics of the gouge material during deformation. Tests are run on saw-cut samples prepared with gouge at 20 MPa confining pressure, 10 MPa pore pressure and at room temperature. Argon or carbon dioxide is used as pore fluid. Sample permeability, stress and strain are monitored continuously during hydrostatic and axial deformation. We find that pressure and shearing both lead to reductions in permeability. Adsorbing gas leads to swelling and promotes permeability reduction, but appears to have no effect on frictional properties. These results indicate that the seal integrity of clay-rich caprocks may not be compromised by shear deformation, and that depletion and shear deformation of unconventional reservoirs is expected to result in production declines.
Decision-Assist and Closed-Loop Control of Fluid Therapy
2012-03-30
achieve target endpoints while reducing fluid needs in experimental models of hemorrhage. During the previous funding cycle, along with our... IABP ) (standard of care blood pressure monitor "gold standard") in cardiac surgical patients to blood pressure recorded by the WVSM. Rational for...WVSM vs Gold standard IABP 2) History of neuropraxia 3) Refusal to consent 4) Failure to obtain radial artery cannulation Ten CPB Patients were
Sub-micron surface plasmon resonance sensor systems
NASA Technical Reports Server (NTRS)
Glazier, James A. (Inventor); Amarie, Dragos (Inventor)
2013-01-01
Wearable or implantable devices combining microfluidic control of sample and reagent flow and micro-cavity surface plasmon resonance sensors functionalized with surface treatments or coatings capable of specifically binding to target analytes, ligands, or molecules in a bodily fluid are provided. The devices can be used to determine the presence and concentration of target analytes in the bodily fluids and thereby help diagnose, monitor or detect changes in disease conditions.
NASA Technical Reports Server (NTRS)
1985-01-01
Under NASA contracts, McDonnell Douglas developed a microbial load monitor to detect bacterial contamination. Vitek Systems, Inc., a subsidiary, was created to commercialize the product for analyzing body fluids. With the AutoMicrobic System, infections may be treated more quickly. The process involves injecting the fluid into identification cards and screening the reaction. Antibiotic treatments are also suggested. Time in hospital and human error is reduced. There are also possible industrial and environmental applications.
2011-07-01
fluid resistivity , temperature logging, and flow metering at other sites that typically indicated only two or three active fractures in each hole...was consistent with results of conventional borehole fluid resistivity , temperature logging, and flow metering at other sites that typically indicated...following tests were performed in each boundary monitoring well: ■ Gamma Ray; ■ Spontaneous Potential (SP); ■ Single Point Resistance (SPR
Malamud, Daniel; Rodriguez-Chavez, Isaac R.
2010-01-01
Synopsis Salivary diagnostics is a dynamic and emerging field utilizing nanotechnology and molecular diagnostics to aid in the diagnosis of oral and systemic diseases. Here, we critically review the latest advances using oral biomarkers for disease detection. The use of oral fluids is broadening perspectives in clinical diagnosis, disease monitoring and decision making for patient care. Important elements determining the future possibilities and challenges in this field are also discussed. PMID:21094724
Photonic Low Cost Micro-Sensor for in-Line Wear Particle Detection in Flowing Lube Oils.
Mabe, Jon; Zubia, Joseba; Gorritxategi, Eneko
2017-03-14
The presence of microscopic particles in suspension in industrial fluids is often an early warning of latent or imminent failures in the equipment or processes where they are being used. This manuscript describes work undertaken to integrate different photonic principles with a micro- mechanical fluidic structure and an embedded processor to develop a fully autonomous wear debris sensor for in-line monitoring of industrial fluids. Lens-less microscopy, stroboscopic illumination, a CMOS imager and embedded machine vision technologies have been merged to develop a sensor solution that is able to detect and quantify the number and size of micrometric particles suspended in a continuous flow of a fluid. A laboratory test-bench has been arranged for setting up the configuration of the optical components targeting a static oil sample and then a sensor prototype has been developed for migrating the measurement principles to real conditions in terms of operating pressure and flow rate of the oil. Imaging performance is quantified using micro calibrated samples, as well as by measuring real used lubricated oils. Sampling a large fluid volume with a decent 2D spatial resolution, this photonic micro sensor offers a powerful tool at very low cost and compacted size for in-line wear debris monitoring.
Photonic Low Cost Micro-Sensor for in-Line Wear Particle Detection in Flowing Lube Oils
Mabe, Jon; Zubia, Joseba; Gorritxategi, Eneko
2017-01-01
The presence of microscopic particles in suspension in industrial fluids is often an early warning of latent or imminent failures in the equipment or processes where they are being used. This manuscript describes work undertaken to integrate different photonic principles with a micro- mechanical fluidic structure and an embedded processor to develop a fully autonomous wear debris sensor for in-line monitoring of industrial fluids. Lens-less microscopy, stroboscopic illumination, a CMOS imager and embedded machine vision technologies have been merged to develop a sensor solution that is able to detect and quantify the number and size of micrometric particles suspended in a continuous flow of a fluid. A laboratory test-bench has been arranged for setting up the configuration of the optical components targeting a static oil sample and then a sensor prototype has been developed for migrating the measurement principles to real conditions in terms of operating pressure and flow rate of the oil. Imaging performance is quantified using micro calibrated samples, as well as by measuring real used lubricated oils. Sampling a large fluid volume with a decent 2D spatial resolution, this photonic micro sensor offers a powerful tool at very low cost and compacted size for in-line wear debris monitoring. PMID:28335436
DOE Office of Scientific and Technical Information (OSTI.GOV)
Richard D. Miller; Abdelmoneam E. Raef; Alan P. Byrnes
2005-09-01
The objective of this research project is to acquire, process, and interpret multiple high-resolution 3-D compressional wave and 2-D, 2-C shear wave seismic data to observe changes in fluid characteristics in an oil field before, during, and after the miscible carbon dioxide (CO{sub 2}) flood that began around December 1, 2003, as part of the DOE-sponsored Class Revisit Project (DOE DE-AC26-00BC15124). Unique and key to this imaging activity is the high-resolution nature of the seismic data, minimal deployment design, and the temporal sampling throughout the flood. The 900-m-deep test reservoir is located in central Kansas oomoldic limestones of the Lansing-Kansasmore » City Group, deposited on a shallow marine shelf in Pennsylvanian time. After 18 months of seismic monitoring, one baseline and six monitor surveys clearly imaged changes that appear consistent with movement of CO{sub 2} as modeled with fluid simulators.« less
Monitoring the health of power transformers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kirtley, J.L. Jr.; Hagman, W.H.; Lesieutre, B.C.
This article reviews MIT`s model-based system which offers adaptive, intelligent surveillance of transformers, and summons attention to anomalous operation through paging devices. Failures of large power transformers are problematic for four reasons. Generally, large transformers are situated so that failures present operational problems to the system. In addition, large power transformers are encased in tanks of flammable and environmentally hazardous fluid. Failures are often accompanied by fire and/or spillage of this fluid. This presents hazards to people, other equipment and property, and the local environment. Finally, large power transformers are costly devices. There is a clear incentive for utilities tomore » keep track of the health of their power transformers. Massachusetts Institute of Technology (MIT) has developed an adaptive, intelligent, monitoring system for large power transformers. Four large transformers on the Boston Edison system are under continuous surveillance by this system, which can summon attention to anomalous operation through paging devices. The monitoring system offers two advantages over more traditional (not adaptive) methods of tracking transformer operation.« less
HSV2 acute retinal necrosis: diagnosis and monitoring with quantitative polymerase chain reaction.
Cottet, L; Kaiser, L; Hirsch, H H; Baglivo, E
2009-06-01
To describe a case of HSV2 acute retinal necrosis (ARN) diagnosed and monitored with quantitative polymerase chain reaction (PCR) in ocular fluids. Case report. Quantitative PCR was performed in the aqueous humor (AH) and vitreous using primers specific for herpes virus. A positive PCR was found for HSV2 in the AH (>100,000,000 viral copies - 8.00 log/ml). After therapy, another anterior chamber tap showed a reduction of the viral load at 4.28 log/ml (19205 copies), confirming the efficacy of the treatment. After six months, PCR on the vitreous still showed the presence of HSV2 viral particles in the eye (3.14 log DNA copies/ml, 1379 copies) although the lesion was healed. This case demonstrates that PCR is useful to detect viral DNA in AH and vitreous and to monitor viral activity and therapeutic response. Viral DNA persists in ocular fluids for months in the presence of a healed infection.
Kauric-Klein, Zorica
2012-01-01
Hypertension in patients on hemodialysis (HD) contributes significantly to their morbidity and mortality. This study examined whether a supportive nursing intervention incorporating monitoring, goal setting, and reinforcement can improve blood pressure (BP) control in a chronic HD population. A randomized controlled design was used and 118 participants were recruited from six HD units in the Detroit metro area. The intervention consisted of (1) BP education sessions; (2) a 12-week intervention, including monitoring, goal setting, and reinforcement; and (3) a 30-day post-intervention follow-up period. Participants in the treatment were asked to monitor their BP, sodium, and fluid intake weekly for 12 weeks in weekly logs. BP, fluid and sodium logs were reviewed weekly with the researcher to determine if goals were met or not met. Reinforcement was given for goals met and problem solving offered when goals were not met. The control group received standard care. Both systolic and diastolic BPs were significantly decreased in the treatment group.
Zhang, Haoyue; Young, Sarah P; Auray-Blais, Christiane; Orchard, Paul J; Tolar, Jakub; Millington, David S
2011-07-01
New therapies for the treatment of mucopolysaccharidoses that target the brain, including intrathecal enzyme replacement, are being explored. Quantitative analysis of the glycosaminoglycans (GAGs) that accumulate in these disorders is required to assess the disease burden and monitor the effect of therapy in affected patients. Because current methods lack the required limit of quantification and specificity to analyze GAGs in small volumes of cerebrospinal fluid (CSF), we developed a method based on ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). Samples of CSF (25 μL) were evaporated to dryness and subjected to methanolysis. The GAGs were degraded to uronic acid-N-acetylhexosamine dimers and mixed with internal standards derived from deuteriomethanolysis of GAG standards. Specific dimers derived from heparan, dermatan and chondroitin sulfates (HS, DS and CS) were separated by UPLC and analyzed by electrospray ionization MS/MS using selected reaction monitoring for each targeted GAG product and its corresponding internal standard. CSF from control pediatric subjects (n = 22) contained <0.38 mg/L HS, 0.26 mg/L DS, and 2.8 mg/L CS, whereas CSF from patients with Hurler syndrome (n = 7) contained concentrations of DS and HS that were at least 6-fold greater than the upper control limits. These concentrations were reduced by 17.5% to 82.5% after allogeneic transplantation and treatment with intrathecal and intravenous enzyme replacement therapy. The method described here has potential value in monitoring patients with mucopolysaccharidoses receiving treatment targeted to the brain.
Okahara, Shigeyuki; Zu Soh; Takahashi, Shinya; Sueda, Taijiro; Tsuji, Toshio
2016-08-01
We proposed a blood viscosity estimation method based on pressure-flow characteristics of oxygenators used during cardiopulmonary bypass (CPB) in a previous study that showed the estimated viscosity to correlate well with the measured viscosity. However, the determination of the parameters included in the method required the use of blood, thereby leading to high cost of calibration. Therefore, in this study we propose a new method to monitor blood viscosity, which approximates the pressure-flow characteristics of blood considered as a non-Newtonian fluid with characteristics of a Newtonian fluid by using the parameters derived from glycerin solution to enable ease of acquisition. Because parameters used in the estimation method are based on fluid types, bovine blood parameters were used to calculate estimated viscosity (ηe), and glycerin parameters were used to estimate deemed viscosity (ηdeem). Three samples of whole bovine blood with different hematocrit levels (21.8%, 31.0%, and 39.8%) were prepared and perfused into the oxygenator. As the temperature changed from 37 °C to 27 °C, the oxygenator mean inlet pressure and outlet pressure were recorded for flows of 2 L/min and 4 L/min, and the viscosity was estimated. The value of deemed viscosity calculated with the glycerin parameters was lower than estimated viscosity calculated with bovine blood parameters by 20-33% at 21.8% hematocrit, 12-27% at 31.0% hematocrit, and 10-15% at 39.8% hematocrit. Furthermore, deemed viscosity was lower than estimated viscosity by 10-30% at 2 L/min and 30-40% at 4 L/min. Nevertheless, estimated and deemed viscosities varied with a similar slope. Therefore, this shows that deemed viscosity achieved using glycerin parameters may be capable of successfully monitoring relative viscosity changes of blood in a perfusing oxygenator.
Hahn, Robert G
2017-01-01
A high number of blood cells increases the viscosity of the blood. The present study explored whether variations in blood cell counts are relevant to the distribution and elimination of infused crystalloid fluid. On three different occasions, 10 healthy male volunteers received an intravenous infusion of 25mL/kg of Ringer's acetate, Ringer's lactate, and isotonic saline over 30min. Blood hemoglobin and urinary excretion were monitored for 4h and used as input in a two-volume kinetic model, using nonlinear mixed effects software. The covariates used in the kinetic model were red blood cell and platelet counts, the total leukocyte count, the use of isotonic saline, and the arterial pressure. Red blood cell and platelet counts in the upper end of the normal range were associated with a decreased rate of distribution and redistribution of crystalloid fluid. Simulations showed that high counts were correlated with volume expansion of the peripheral (interstitial) fluid space, while the plasma volume was less affected. In contrast, the total leukocyte count had no influence on the distribution, redistribution, or elimination. The use of isotonic saline caused a transient reduction in the systolic arterial pressure (P<0.05) and doubled the half-life of infused fluid in the body when compared to the two Ringer solutions. Isotonic saline did not decrease the serum potassium concentration, despite the fact that saline is potassium-free. High red blood cell and platelet counts are associated with peripheral accumulation of infused crystalloid fluid. Copyright © 2017 The Lithuanian University of Health Sciences. Production and hosting by Elsevier Sp. z o.o. All rights reserved.
Blood glucose level reconstruction as a function of transcapillary glucose transport.
Koutny, Tomas
2014-10-01
A diabetic patient occasionally undergoes a detailed monitoring of their glucose levels. Over the course of a few days, a monitoring system provides a detailed track of their interstitial fluid glucose levels measured in their subcutaneous tissue. A discrepancy in the blood and interstitial fluid glucose levels is unimportant because the blood glucose levels are not measured continuously. Approximately five blood glucose level samples are taken per day, and the interstitial fluid glucose level is usually measured every 5min. An increased frequency of blood glucose level sampling would cause discomfort for the patient; thus, there is a need for methods to estimate blood glucose levels from the glucose levels measured in subcutaneous tissue. The Steil-Rebrin model is widely used to describe the relationship between blood and interstitial fluid glucose dynamics. However, we measured glucose level patterns for which the Steil-Rebrin model does not hold. Therefore, we based our research on a different model that relates present blood and interstitial fluid glucose levels to future interstitial fluid glucose levels. Using this model, we derived an improved model for calculating blood glucose levels. In the experiments conducted, this model outperformed the Steil-Rebrin model while introducing no additional requirements for glucose sample collection. In subcutaneous tissue, 26.71% of the calculated blood glucose levels had absolute values of relative differences from smoothed measured blood glucose levels less than or equal to 5% using the Steil-Rebrin model. However, the same difference interval was encountered in 63.01% of the calculated blood glucose levels using the proposed model. In addition, 79.45% of the levels calculated with the Steil-Rebrin model compared with 95.21% of the levels calculated with the proposed model had 20% difference intervals. Copyright © 2014 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Marques, Joana; Corby, Patricia M.; Barber, Cheryl A.; Abrams, William R.; Malamud, Daniel
2015-05-01
The field of "salivary diagnostics" includes studies utilizing samples obtained from a variety of sources within the oral cavity. These samples include; whole unstimulated saliva, stimulated whole saliva, duct saliva collected directly from the parotid, submandibular/sublingual glands or minor salivary glands, swabs of the buccal mucosa, tongue or tonsils, and gingival crevicular fluid. Many publications state "we collected saliva from subjects" without fully describing the process or source of the oral fluid. Factors that need to be documented in any study include the time of day of the collection, the method used to stimulate and collect the fluid, and how much fluid is being collected and for how long. The handling of the oral fluid during and post-collection is also critical and may include addition of protease or nuclease inhibitors, centrifugation, and cold or frozen storage prior to assay. In an effort to create a standard protocol for determining a biomarker's origin we carried out a pilot study collecting oral fluid from 5 different sites in the mouth and monitoring the concentrations of pro- and anti-inflammatory cytokines detected using MesoScaleDiscovery (MSD) electrochemiluminesence assays. Our data suggested that 3 of the cytokines are primarily derived from the submandibular gland, while 7 of the cytokines come from a source other than the major salivary glands such as the minor salivary glands or cells in the oral mucosae. Here we review the literature on monitoring biomarkers in oral samples and stress the need for determining the blood/saliva ratio when a quantitative determination is needed and suggest that the term oral diagnostic be used if the source of an analyte in the oral cavity is unknown.
Farber, Paul S.; Huang, Hann-Shen
2001-01-01
A method for analyzing metal in a fluid is provided comprising maintaining a first portion of a continuous filter media substrate at a temperature coinciding with the phase in which the metal is to be analyzed; contacting the fluid to a first portion of said substrate to retain the metal on the first portion of said substrate; preventing further contact of the fluid to the first portion of substrate; and contacting the fluid to a second portion of said substrate to retain metal on the second portion of the said substrate while simultaneously analyzing the first portion for metal. Also provided is a device for the simultaneous monitoring and analysis of metal in a fluid comprising a continuous filter media substrate; means for maintaining a first portion of said filter media substrate at a temperature coinciding with the phase in which the metal is to be analyzed; a means for contacting the fluid to the first portion of said substrate; a means for preventing further contact of the fluid to the first portion of substrate; a means for contacting the fluid to a second portion of said substrate to retain metal on the second portion of the said substrate; and means for analyzing the first portion for metal.
Improvement and automation of a real-time PCR assay for vaginal fluids.
De Vittori, E; Giampaoli, S; Barni, F; Baldi, M; Berti, A; Ripani, L; Romano Spica, V
2016-05-01
The identification of vaginal fluids is crucial in forensic science. Several molecular protocols based on PCR amplification of mfDNA (microflora DNA) specific for vaginal bacteria are now available. Unfortunately mfDNA extraction and PCR reactions require manual optimization of several steps. The aim of present study was the verification of a partial automatization of vaginal fluids identification through two instruments widely diffused in forensic laboratories: EZ1 Advanced robot and Rotor Gene Q 5Plex HRM. Moreover, taking advantage of 5-plex thermocycler technology, the ForFluid kit performances were improved by expanding the mfDNA characterization panel with a new bacterial target for vaginal fluids and with an internal positive control (IPC) to monitor PCR inhibition. Results underlined the feasibility of a semi-automated extraction of mfDNA using a BioRobot and demonstrated the analytical improvements of the kit. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
The choice of amniotic fluid in metabolomics for the monitoring of fetus health.
Palmas, Francesco; Fattuoni, Claudia; Noto, Antonio; Barberini, Luigi; Dessì, Angelica; Fanos, Vassilios
2016-01-01
Amniotic fluid (AF) is a biological fluid in which metabolite transport is regulated by the placenta, the permeable skin, fetal lung egress and gastric fluid. During pregnancy, the composition of AF changes from similar to the interstitial fluid of the mother, to a more complex system, influenced by the fetus's urine. Since AF reflects the mother's and the fetus's health status at the same time, it may be an important diagnostic tool for a wider spectrum of clinical conditions. Indeed, the metabolic characterization of AF in relation to pathological occurrences may lead to the discovery of new biomarkers for a better clinical practice. For this reason, metabolomics may be the most suitable strategy for this task. In this review, research works on metabolomic AF analysis are discussed according to the morbidity of interest, being preterm birth/labor, gestational age and diabetes and fetal malformations, along with a number of other important studies.
Drinking and water balance during exercise and heat acclimation
NASA Technical Reports Server (NTRS)
Greenleaf, J. E.; Brock, P. J.; Keil, L. C.; Morse, J. T.
1983-01-01
The interactions between fluid intake and balance, and plasma ion, osmotic, and endocrine responses during dehydration produced by exercise in cool and warm environments during acclimation are explored. Two groups of five male subjects performed 8 days of ergometer exercise in hot and thermoneutral conditions, respectively. The exercise trials lasted 2 hr each. Monitoring was carried out on the PV, osmotic, sodium, and endocrine concentrations, voluntary fluid intake, fluid balances, and fluid deficits. A negative correlation was observed between the plasma sodium and osmolality during acclimation. The presence of hypervolemia during acclimation is suggested as a cause of drinking, while the vasopressin concentration was not found to be a significant factor stimulating drinking. Finally, the predominant mechanism in fluid intake during exercise and heat exposure is concluded to be the renin-angiotensin II system in the presence of reductions in total body water and extracellular plasma volumes.
Gunn, E; Shiel, R E; Mooney, C T
2016-05-01
The objectives of this study were to describe the efficacy, outcome and adverse effects of intravenous hydrocortisone and fluid therapy for the management of acute hypoadrenocorticism in dogs. A retrospective review of dogs with primary hypoadrenocorticism receiving intravenous hydrocortisone and fluid therapy was performed. Thirty newly-diagnosed dogs were included. There was an excellent clinical response, with all dogs surviving to discharge within a median of 2 days. In 23 cases with complete data, the mean rate of change of sodium over 24 hours was 0·48 (±0·28) mmol/L/hour, while the mean rate of change of potassium was -0·12 (±0·06) mmol/L/hour. Circulating potassium concentration normalised in 68·4% and 100% of cases of by 12 and 24 hours, respectively. Additional treatment for hyperkalaemia was not found necessary. Plasma sodium concentration increased by >12 mmol/L/24 hours on 7 of 23 (30·4%) occasions. One dog exhibited associated temporary neurological signs. Intravenous hydrocortisone infusion and fluid therapy for the management of acute hypoadrenocorticism is associated with a rapid resolution of hyperkalaemia and is well tolerated with few adverse effects. Regular electrolyte monitoring is required to ensure that rapid increases in sodium concentration are avoided. © 2016 British Small Animal Veterinary Association.
Frasca, Denis; Dahyot-Fizelier, Claire; Adier, Christophe; Mimoz, Olivier; Debaene, Bertrand; Couet, William
2014-01-01
The distribution of metronidazole in the central nervous system has only been described based on cerebrospinal fluid data. However, extracellular fluid (ECF) concentrations may better predict its antimicrobial effect and/or side effects. We sought to explore by microdialysis brain ECF metronidazole distribution in patients with acute brain injury. Four brain-injured patients monitored by cerebral microdialysis received 500 mg of metronidazole over 0.5 h every 8 h. Brain dialysates and blood samples were collected at steady state over 8 h. Probe recoveries were evaluated by in vivo retrodialysis in each patient for metronidazole. Metronidazole and OH-metronidazole were assayed by high-pressure liquid chromatography, and a noncompartmental pharmacokinetic analysis was performed. Probe recovery was equal to 78.8% ± 1.3% for metronidazole in patients. Unbound brain metronidazole concentration-time curves were delayed compared to unbound plasma concentration-time curves but with a mean metronidazole unbound brain/plasma AUC0–τ ratio equal to 102% ± 19% (ranging from 87 to 124%). The unbound plasma concentration-time profiles for OH-metronidazole were flat, with mean average steady-state concentrations equal to 4.0 ± 0.7 μg ml−1. This microdialysis study describes the steady-state brain distribution of metronidazole in patients and confirms its extensive distribution. PMID:24277041
21 CFR 880.2460 - Electrically powered spinal fluid pressure monitor.
Code of Federal Regulations, 2013 CFR
2013-04-01
... SERVICES (CONTINUED) MEDICAL DEVICES GENERAL HOSPITAL AND PERSONAL USE DEVICES General Hospital and... electrical signal. The device includes signal amplification, conditioning, and display equipment. (b...
21 CFR 880.2460 - Electrically powered spinal fluid pressure monitor.
Code of Federal Regulations, 2012 CFR
2012-04-01
... SERVICES (CONTINUED) MEDICAL DEVICES GENERAL HOSPITAL AND PERSONAL USE DEVICES General Hospital and... electrical signal. The device includes signal amplification, conditioning, and display equipment. (b...
21 CFR 880.2460 - Electrically powered spinal fluid pressure monitor.
Code of Federal Regulations, 2014 CFR
2014-04-01
... SERVICES (CONTINUED) MEDICAL DEVICES GENERAL HOSPITAL AND PERSONAL USE DEVICES General Hospital and... electrical signal. The device includes signal amplification, conditioning, and display equipment. (b...
Johnson, Carole D.; White, Eric A.; Joesten, Peter K.
2012-01-01
Time‐lapse geophysical surveys using frequency‐domain electromagnetics (FDEM) can indirectly measure time‐varying hydrologic parameters such as fluid saturation or solute concentration. Monitoring of these processes provides insight into aquifer properties and the effectiveness of constructed controls (such as leachate interceptor trenches), as well as aquifer responses to natural or induced stresses. At the University of Connecticut landfill, noninvasive, electromagnetic induction (EMI) methods were used to monitor changes in subsurface electrical conductivity that were related to the landfill‐closure activities. After the landfill was closed, EMI methods were used to monitor changes in water saturation and water quality. As part of a long‐term monitoring plan to observe changes associated with closure, redevelopment, and remediation of the former landfill, EMI data were collected to supplement information from groundwater samples collected in wells to the south and north of the landfill. In comparison to single‐point measurements that could have been collected by conventional installation of additional monitoring wells, the EMI methods provided increased spatial coverage, and were less invasive and therefore less destructive to the wetland north of the landfill. To monitor effects of closure activities on the subsurface conductivity, EMI measurements were collected from 2004 to 2011 along discrete transects north and south of the landfill prior to, during, and after the landfill closure. In general, the results indicated an overall decline in subsurface electrical conductivity with time and with distance from the former landfill. This decline in electrical conductivity indicated that the closure and remediation efforts reduced the amount of leachate that originated from the landfill and that entered the drainages to the north and south of the landfill.
System and technique for characterizing fluids using ultrasonic diffraction grating spectroscopy
Greenwood, Margaret S.
2005-04-12
A system for determining a property of a fluid based on ultrasonic diffraction grating spectroscopy includes a diffraction grating on a solid in contact with the fluid. An interrogation device delivers ultrasound through the solid and a captures a reflection spectrum from the diffraction grating. The reflection spectrum including a diffraction order equal to zero exhibits a peak whose location is used to determine speed of sound in the fluid. A separate measurement of the acoustic impedance is combined with the determined speed of sound to yield a measure of fluid density. A system for determining acoustic impedance includes an ultrasonic transducer on a first surface of a solid member, and an opposed second surface of the member is in contact with a fluid to be monitored. A longitudinal ultrasonic pulse is delivered through the solid member, and a multiplicity of pulse echoes caused by reflections of the ultrasonic pulse between the solid-fluid interface and the transducer-solid interface are detected. The decay rate of the detected echo amplitude as a function of echo number is used to determine acoustic impedance.
The US Army Burn Center: Professional Service During 10 Years of War
2012-01-01
therapist Registered respiratory therapist Clinical nutrition Registered dietician Dietary technician Social work and case management Licensed clinical...resuscitation fluid volume cal- culation termed the Rule of Ten.12 Education regarding the intended use of the CPG and the BRF was provided through...Intraoperative hemodynamic monitoring includes the use of transesophageal echocardiography and noninvasive continuous hemoglobin monitoring combined with
Bonneville, Alain; Heggy, Essam; Strickland, Christopher E.; ...
2015-08-11
A main issue in the storage of large volumes of fluids, mainly water and CO 2, in the deep subsurface is to determine their field-scale-induced displacements and consequences on the mechanical behavior of the storage reservoir and surroundings. A quantifiable estimation of displacement can be made by combining the robust, cost-effective, and repeatable geophysical techniques of micro-gravimetry, differential global positioning system (DGPS), and differential synthetic aperture radar interferometry (DInSAR). These techniques were field tested and evaluated in an active large-volume aquifer storage and recovery (ASR) project in Pendleton, Oregon, USA, where three ASR wells are injecting up to 1.9 millionmore » m 3/yr -1 into basalt aquifers to a depth of about 150 m. Injection and recovery of water at the wells was accompanied by significant gravity anomalies and vertical deformation of the ground surface localized to the immediate surroundings of the injection wells as evidenced by DGPS and gravity measurements collected in 2011. At a larger scale, and between 2011 and 2013, DInSAR monitoring of the Pendleton area suggests the occurrence of sub-centimetric deformation in the western part of the city and close to the injection locations associated with the ASR cycle. A numerical simulation of the effect of the water injection gives results in good agreement with the observations and confirms the validity of the approach, which could be deployed in similar geological contexts to look at the mechanical effects of water and gas injections. The gravity signal reflects deep phenomena and gives additional insight into the repartition of fluids in the subsurface.« less
Tait, R D; Maxon, C L; Parr, T D; Newton, F C
2016-09-15
The effects of linear alpha olefin (LAO) nonaqueous drilling fluid on benthic macrofauna were assessed over a six year period at a southern Caspian Sea petroleum exploration site. A wide-ranging, pre-drilling survey identified a relatively diverse shelf-depth macrofauna numerically dominated by amphipods, cumaceans, and gastropods that transitioned to a less diverse assemblage dominated by hypoxia-tolerant annelid worms and motile ostracods with increasing depth. After drilling, a similar transition in macrofauna assemblage was observed with increasing concentration of LAO proximate to the shelf-depth well site. Post-drilling results were consistent with a hypothesis of hypoxia from microbial degradation of LAO, supported by the presence of bacterial mats and lack of oxygen penetration in surface sediment. Chemical and biological recoveries at ≥200m distance from the well site were evident 33months after drilling ceased. Our findings show the importance of monitoring recovery over time and understanding macrofauna community structure prior to drilling. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
NASA Astrophysics Data System (ADS)
Faulkner, D. R.; Armitage, P. J.
2011-12-01
Geothermal fields rely on permeable fracture networks that can act for significant periods of time. In crystalline rocks, permeability may be stimulated by injections of fluid pressure at depth. We show how high-pressure laboratory experiments can be used to quantify the effects of different stress states on the permeability of two rocks; Darley Dale sandstone (~10-16 m2 permeability) and Westerly granite (~10-20 m2 permeability). It is well known that microfractures start to grow at stresses around one half of the failure stress. Failure in the experiments was reproduced in several ways: (1) by fixing σ3 and increasing σ1 - equivalent to a compressive or strike-slip tectonic regime (2) by fixing σ1 and decreasing σ3 - equivalent to an extensional tectonic regime (3) by increasing the pore fluid pressure at a fixed differential stress to simulate high pore fluid pressure failure, and (4) by fixing the mean stress while increasing σ1 and decreasing σ3 in sympathy. Permeability was monitored during all of these tests. From these tests we are able to quantify the relative contributions of mean stress, differential stress and pore fluid pressure on the permeability in the pre-failure region. This provides key data on the development of microfracture permeability that might be produced during the stimulation of geothermal fields during injection within different tectonic environments.
Comparison of Ocular Outcomes in Two 14-Day Bed Rest Studies
NASA Technical Reports Server (NTRS)
Cromwell, Ronita L.; Zanello, S. B.; Yarbough, P. O.; Tabbi, G.; Vizzeri, G.
2012-01-01
Reports of astronauts' visual changes have raised concern about ocular health during long-duration spaceflight. Some of these findings include globe flattening with hyperopic shifts, choroidal folds, optic disc edema, retinal nerve fiber layer (RNFL) thickening, and cotton wool spots. While the etiology remains unknown, it is hypothesized that, in predisposed individuals, hypertension in the brain may follow cephalad fluid shifts during spaceflight. This possible mechanism of ocular changes may also apply to analogous cases of idiopathic intracranial hypertension (IIH) or pseudotumor cerebri on Earth patients. Head-down t ilt (HDT) bed rest is a spaceflight analog that induces cephalad fluid shifts. Previous studies of the HDT position demonstrated body fluid shifts associated with changes in intraocular pressure (IOP) but the conditions of bed rest varied among experiments, making it difficult to compare data and draw conclusions. For these reasons, vision evaluation of bed rest subjects was implemented for NASA bed rest studies since 2010, in an attempt to monitor vision health in subjects subjected to bed rest. Vision monitoring is thus currently performed in all NASA-conducted bed rest campaigns
GFFC, Commander Ken Bowersox monitors Spacelab experiment
1995-11-05
STS073-363-032 (20 October - 5 November 1995) --- Astronaut Kenneth D. Bowersox, STS-73 mission commander, studies the movement of fluids in microgravity at the Geophysical Fluid Flow Cell (GFFC) workstation in the science module of the Earth-orbiting Space Shuttle Columbia. Bowersox was joined by four other NASA astronauts and two guest researchers for almost 16-days of Earth-orbit research in support of the U.S. Microgravity Laboratory (USML-2) mission.
Waterproof stretchable optoelectronics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rogers, John A.; Kim, Rak-Hwan; Kim, Dae-Hyeong
Described herein are flexible and stretchable LED arrays and methods utilizing flexible and stretchable LED arrays. Assembly of flexible LED arrays alongside flexible plasmonic crystals is useful for construction of fluid monitors, permitting sensitive detection of fluid refractive index and composition. Co-integration of flexible LED arrays with flexible photodetector arrays is useful for construction of flexible proximity sensors. Application of stretchable LED arrays onto flexible threads as light emitting sutures provides novel means for performing radiation therapy on wounds.
Non-invasive fluid density and viscosity measurement
Sinha, Dipen N [Los Alamos, NM
2012-05-01
The noninvasively measurement of the density and viscosity of static or flowing fluids in a section of pipe such that the pipe performs as the sensing apparatus, is described. Measurement of a suitable structural vibration resonance frequency of the pipe and the width of this resonance permits the density and viscosity to be determined, respectively. The viscosity may also be measured by monitoring the decay in time of a vibration resonance in the pipe.
Optical nondestructive dynamic measurements of wafer-scale encapsulated nanofluidic channels.
Liberman, Vladimir; Smith, Melissa; Weaver, Isaac; Rothschild, Mordechai
2018-05-20
Nanofluidic channels are of great interest for DNA sequencing, chromatography, and drug delivery. However, metrology of embedded or sealed nanochannels and measurement of their fill-state have remained extremely challenging. Existing techniques have been restricted to optical microscopy, which suffers from insufficient resolution, or scanning electron microscopy, which cannot measure sealed or embedded channels without cleaving the sample. Here, we demonstrate a novel method for accurately extracting nanochannel cross-sectional dimensions and monitoring fluid filling, utilizing spectroscopic ellipsometric scatterometry, combined with rigorous electromagnetic simulations. Our technique is capable of measuring channel dimensions with better than 5-nm accuracy and assessing channel filling within seconds. The developed technique is, thus, well suited for both process monitoring of channel fabrication as well as for studying complex phenomena of fluid flow through nanochannel structures.
Shigemi, Kenji
2016-05-01
To maintain proper cardiac preload is one of the most effective procedures for the systemic circulation remaining stable. In particular, the balance between vascular capacity and total blood volume must be maintained within appropriate range by the administration of fluids, blood and/or vasoactive drugs with mean circulatory filling pressure (Pmcf), central venous pressure (CVP) or stroke volume variation (SVV). End-diastolic left ventricular volume (Ved) is theoretically the best index of cardiac preload; however, without transesophageal echocardbalanceiogram we cannot directly monitor Ved during anesthesia. The infused fluid volume remaining in intravascular space, the vascular capacity controlled by autonomic nervous system and/or vasoactive agents, and the unstressed blood volume properly mobilized to excess blood volume are the crucial factors to maintain cardiac output The knowledge of vascular physiology contribute the decision making to manipulate such factors to control blood circulation during general anesthesia. For example, CVP is usually maintained in the narrow range and seems to be stable; however, it must be changed just after the circulatory disturbances, such as acute bleeding, blood transfusion, and fluid infusion, and followed by gradual returning to initial value, because of the solid mechanism to preserve cardiac output
Lourenço, Vera; Herdling, Thorsten; Reich, Gabriele; Menezes, José C; Lochmann, Dirk
2011-08-01
A set of 192 fluid bed granulation batches at industrial scale were in-line monitored using microwave resonance technology (MRT) to determine moisture, temperature and density of the granules. Multivariate data analysis techniques such as multiway partial least squares (PLS), multiway principal component analysis (PCA) and multivariate batch control charts were applied onto collected batch data sets. The combination of all these techniques, along with off-line particle size measurements, led to significantly increased process understanding. A seasonality effect could be put into evidence that impacted further processing through its influence on the final granule size. Moreover, it was demonstrated by means of a PLS that a relation between the particle size and the MRT measurements can be quantitatively defined, highlighting a potential ability of the MRT sensor to predict information about the final granule size. This study has contributed to improve a fluid bed granulation process, and the process knowledge obtained shows that the product quality can be built in process design, following Quality by Design (QbD) and Process Analytical Technology (PAT) principles. Copyright © 2011. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Stovern, Michael; Felix, Omar; Csavina, Janae; Rine, Kyle P.; Russell, MacKenzie R.; Jones, Robert M.; King, Matt; Betterton, Eric A.; Sáez, A. Eduardo
2014-09-01
Mining operations are potential sources of airborne particulate metal and metalloid contaminants through both direct smelter emissions and wind erosion of mine tailings. The warmer, drier conditions predicted for the Southwestern US by climate models may make contaminated atmospheric dust and aerosols increasingly important, due to potential deleterious effects on human health and ecology. Dust emissions and dispersion of dust and aerosol from the Iron King Mine tailings in Dewey-Humboldt, Arizona, a Superfund site, are currently being investigated through in situ field measurements and computational fluid dynamics modeling. These tailings are heavily contaminated with lead and arsenic. Using a computational fluid dynamics model, we model dust transport from the mine tailings to the surrounding region. The model includes gaseous plume dispersion to simulate the transport of the fine aerosols, while individual particle transport is used to track the trajectories of larger particles and to monitor their deposition locations. In order to improve the accuracy of the dust transport simulations, both regional topographical features and local weather patterns have been incorporated into the model simulations. Results show that local topography and wind velocity profiles are the major factors that control deposition.
Stovern, Michael; Felix, Omar; Csavina, Janae; Rine, Kyle P; Russell, MacKenzie R; Jones, Robert M; King, Matt; Betterton, Eric A; Sáez, A Eduardo
2014-09-01
Mining operations are potential sources of airborne particulate metal and metalloid contaminants through both direct smelter emissions and wind erosion of mine tailings. The warmer, drier conditions predicted for the Southwestern US by climate models may make contaminated atmospheric dust and aerosols increasingly important, due to potential deleterious effects on human health and ecology. Dust emissions and dispersion of dust and aerosol from the Iron King Mine tailings in Dewey-Humboldt, Arizona, a Superfund site, are currently being investigated through in situ field measurements and computational fluid dynamics modeling. These tailings are heavily contaminated with lead and arsenic. Using a computational fluid dynamics model, we model dust transport from the mine tailings to the surrounding region. The model includes gaseous plume dispersion to simulate the transport of the fine aerosols, while individual particle transport is used to track the trajectories of larger particles and to monitor their deposition locations. In order to improve the accuracy of the dust transport simulations, both regional topographical features and local weather patterns have been incorporated into the model simulations. Results show that local topography and wind velocity profiles are the major factors that control deposition.
Kick Detection at the Bit: Early Detection via Low Cost Monitoring
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tost, Brian; Rose, Kelly; Aminzadeh, Fred
2016-06-07
Formation fluid influxes (i.e. kicks) pose persistent challenges and operational costs during drilling operations. Implications of kicks range in scale but cumulatively result in substantial costs that affect drilling safety, environment, schedule, and infrastructure. Early kick detection presents a low-cost, easily adopted solution for avoiding well control challenges associated with kicks near the bit. Borehole geophysical tools used during the drilling process as part of the logging-while-drilling (LWD) and measurement-while-drilling (MWD) provide the advantage of offering real-time downhole data. LWD/MWD collect data on both the annulus and borehole wall. The annular data are normally treated as background, and are filteredmore » out to isolate the formation measurements. Because kicks will change the local physical properties of annular fluids, bottom-hole measurements are among the first indicators that a formation fluid has invaded the wellbore. This report describes and validates a technique for using the annular portion of LWD/MWD data to facilitate early kick detection using first order principles. The detection technique leverages data from standard and cost-effective technologies that are typically implemented during well drilling, such as MWD/LWD data in combination with mud-pulse telemetry for data transmission.« less
Stovern, Michael; Felix, Omar; Csavina, Janae; Rine, Kyle P.; Russell, MacKenzie R.; Jones, Robert M.; King, Matt; Betterton, Eric A.; Sáez, A. Eduardo
2014-01-01
Mining operations are potential sources of airborne particulate metal and metalloid contaminants through both direct smelter emissions and wind erosion of mine tailings. The warmer, drier conditions predicted for the Southwestern US by climate models may make contaminated atmospheric dust and aerosols increasingly important, due to potential deleterious effects on human health and ecology. Dust emissions and dispersion of dust and aerosol from the Iron King Mine tailings in Dewey-Humboldt, Arizona, a Superfund site, are currently being investigated through in situ field measurements and computational fluid dynamics modeling. These tailings are heavily contaminated with lead and arsenic. Using a computational fluid dynamics model, we model dust transport from the mine tailings to the surrounding region. The model includes gaseous plume dispersion to simulate the transport of the fine aerosols, while individual particle transport is used to track the trajectories of larger particles and to monitor their deposition locations. In order to improve the accuracy of the dust transport simulations, both regional topographical features and local weather patterns have been incorporated into the model simulations. Results show that local topography and wind velocity profiles are the major factors that control deposition. PMID:25621085
Working research codes into fluid dynamics education: a science gateway approach
NASA Astrophysics Data System (ADS)
Mason, Lachlan; Hetherington, James; O'Reilly, Martin; Yong, May; Jersakova, Radka; Grieve, Stuart; Perez-Suarez, David; Klapaukh, Roman; Craster, Richard V.; Matar, Omar K.
2017-11-01
Research codes are effective for illustrating complex concepts in educational fluid dynamics courses, compared to textbook examples, an interactive three-dimensional visualisation can bring a problem to life! Various barriers, however, prevent the adoption of research codes in teaching: codes are typically created for highly-specific `once-off' calculations and, as such, have no user interface and a steep learning curve. Moreover, a code may require access to high-performance computing resources that are not readily available in the classroom. This project allows academics to rapidly work research codes into their teaching via a minimalist `science gateway' framework. The gateway is a simple, yet flexible, web interface allowing students to construct and run simulations, as well as view and share their output. Behind the scenes, the common operations of job configuration, submission, monitoring and post-processing are customisable at the level of shell scripting. In this talk, we demonstrate the creation of an example teaching gateway connected to the Code BLUE fluid dynamics software. Student simulations can be run via a third-party cloud computing provider or a local high-performance cluster. EPSRC, UK, MEMPHIS program Grant (EP/K003976/1), RAEng Research Chair (OKM).
Seitz, J.C.; Pasteris, J.D.; Chou, I.-Ming
1996-01-01
Raman spectral parameters were determined for the v1 band of CH4 and the v1 and 2v2 bands (Fermi diad) of CO2 in pure CO2 and CO2-CH4 mixtures at pressures up to 700 bars and room temperature. Peak position, area, height, and width were investigated as functions of pressure and composition. The peak positions of the CH4 and CO2 bands shift to lower relative wavenumbers as fluid pressure is increased. The peak position of the lower-wavenumber member of the Fermi diad for CO2 is sensitive to fluid composition, whereas the peak positions of the CH4 band and the upper Fermi diad member for CO2 are relatively insensitive in the CO2-CH4 system. The magnitude of the shifts in each of the three peak positions (as a function of pressure) is sufficient to be useful as a monitor of fluid pressure. The relative molar proportions in a CO2-CH4 mixture may be determined from the peak areas: the ratio of the peak areas of the CH4 band and the CO2 upper Fermi diad member is very sensitive to composition, whereas above about 100 bars, it is insensitive to pressure. Likewise, the peak height ratio is very sensitive to composition but also to fluid pressure. The individual peak widths of CO2 and CH4, as well as the ratios of the widths of the CH4 peak to the CO2 peaks are a sensitive function of pressure and, to a lesser extent, composition. Thus, upon determination of fluid composition, the peak width ratios may be used as a monitor of fluid pressure. The application of these spectral parameters to a suite of natural CO2-CH4 inclusions has yielded internally-consistent, quantitative determinations of the fluid composition and density.
NASA Astrophysics Data System (ADS)
Jia, Yali; Bagnaninchi, Pierre O.; Yang, Ying; Haj, Alicia El; Hinds, Monica T.; Kirkpatrick, Sean J.; Wang, Ruikang K.
2009-05-01
Establishing a relationship between perfusion rate and fluid shear stress in a 3D cell culture environment is an ongoing and challenging task faced by tissue engineers. We explore Doppler optical coherence tomography (DOCT) as a potential imaging tool for in situ monitoring of local fluid flow profiles inside porous chitosan scaffolds. From the measured fluid flow profiles, the fluid shear stresses are evaluated. We examine the localized fluid flow and shear stress within low- and high-porosity chitosan scaffolds, which are subjected to a constant input flow rate of 0.5 ml.min-1. The DOCT results show that the behavior of the fluid flow and shear stress in micropores is strongly dependent on the micropore interconnectivity, porosity, and size of pores within the scaffold. For low-porosity and high-porosity chitosan scaffolds examined, the measured local fluid flow and shear stress varied from micropore to micropore, with a mean shear stress of 0.49+/-0.3 dyn.cm-2 and 0.38+/-0.2 dyn.cm-2, respectively. In addition, we show that the scaffold's porosity and interconnectivity can be quantified by combining analyses of the 3D structural and flow images obtained from DOCT.
Lee, Byung Kook; Jeung, Kyung Woon; Lee, Seung Cheol; Min, Yong Il; Ryu, Hyun Ho; Kim, Mu Jin; Lee, Hyoung Youn; Heo, Tag
2010-06-01
This study was undertaken to determine how rapidly refrigerated fluids gain heat during bolus infusion and to determine whether the refrigerated fluids could be kept cold by a simple cold-insulation method. One liter of refrigerated fluid was run through either a 16-gauge catheter (16G(-) and 16G(+) groups) or an 18-gauge catheter (18G(-) and 18G(+) groups) while monitoring the temperature in the fluid bag and the outflow site. In the 16G(+) and the 18G(+) groups, the fluid bag was placed with an ice pack inside an insulating sleeve during the fluid run. In the 16G(-) and the 18G(-) groups, the outflow temperature increased to 10-12 degrees C during the fluid run. Meanwhile, outflow temperatures in the 16G(+) and the 18G(+) groups remained below 4.6 and 6.8 degrees C, respectively. The temperatures differed significantly between the 16G(-) and the 16G(+) groups (p < 0.001) and between the 18G(-) and the 18G(+) groups (p < 0.001), respectively. Substantial heat gain occurred in the refrigerated fluid even during the relatively short duration of bolus infusion. The heat gain could, however, be easily minimized by cold insulation of the fluid bag. (c) 2010 by the Society for Academic Emergency Medicine.
Integrated acoustic phase separator and multiphase fluid composition monitoring apparatus and method
Sinha, Dipen N.
2016-01-12
An apparatus and method for down hole gas separation from the multiphase fluid flowing in a wellbore or a pipe, for determining the quantities of the individual components of the liquid and the flow rate of the liquid, and for remixing the component parts of the fluid after which the gas volume may be measured, without affecting the flow stream, are described. Acoustic radiation force is employed to separate gas from the liquid, thereby permitting measurements to be separately made for these two components; the liquid (oil/water) composition is determined from ultrasonic resonances; and the gas volume is determined from capacitance measurements. Since the fluid flows around and through the component parts of the apparatus, there is little pressure difference, and no protection is required from high pressure differentials.